  1. Spiritual well-being may buffer psychological distress in patients with implantable cardioverter defibrillators (ICD)

    OpenAIRE

    Salmoirago-Blotcher, Elena; Crawford, Sybil; Tran, Chau; Goldberg, Robert; Rosenthal, Lawrence; Ockene, Ira

    2012-01-01

    Psychological distress is common in patients with implantable cardioverter defibrillators (ICDs) and has been associated with a worse prognosis. The authors examined whether spiritual wellbeing is associated with reduced psychological distress in patients with ICDs. The Functional Assessment of Chronic Illness Therapy-Spiritual Wellbeing (FACIT-SWB) questionnare and the Hospital Anxiety and Depression Scale (HADS) were used to measure spiritual wellbeing and overall psychological distress. Mu...

  2. Wearable cardioverter defibrillator: A life vest till the life boat (ICD arrives

    Directory of Open Access Journals (Sweden)

    Johnson Francis

    2014-01-01

    Full Text Available It is well established that implantable cardioverter defibrillator (ICD is a life saving device ensuring protection against life threatening ventricular arrhythmias. But there are certain situations like a recent myocardial infarction where the standard guidelines do not recommend the implantation of an ICD while the patient can still be at a risk of demise due to a life threatening ventricular arrhythmia. There could also be a temporary indication for protection while explanting an infected ICD system. The wearable cardioverter defibrillator (WCD is a device which comes to the rescue in such situations. In this brief review, we discuss the historical aspects of the development of a WCD, technical aspects as well as the clinical trial data and real world scenario of its use.

  3. How does an implantable cardioverter defibrillator (ICD) affect the lives of patients and their families?

    Science.gov (United States)

    Eckert, Marion; Jones, Tina

    2002-06-01

    This study aimed to identify the lived experience of patients with implantable cardioverter defibrillators (ICD) and their families. The methodology used was interpretative phenomenology. Unstructured interviews were conducted with three family members and three ICD recipients. Using a methodological approach outlined by van Manen, the participants transcribed texts were analysed looking for similar concepts and ideas that developed into themes that explicated the meaning of this phenomena. The themes that emerged were: dependence, which encompassed their perceptions about the life-saving device; the memory of their first defibrillation experience; lifestyle changes, which incorporated modification techniques; lack of control, which highlighted feelings such as fear, anxiety and powerlessness; mind game, which illustrated psychological challenges; and the issue of security, demonstrating how 'being there' and not 'being there' impacted on their everyday lives. The long-term outcomes of living with an ICD are important considerations for all health-care providers. This research highlights the everyday activities of recipients, the lifestyle changes they have made, the emotional significance of the device and the psychological coping strategies that the participants have adopted. The findings of this research will allow health-care professionals to be better prepared to provide education and support for ICD recipients and their families in regards to issues related to insertion of the device during the postinsertion recovery period and for long-term management after hospital discharge.

  4. Cognitive behavioral therapy (CBT in a Patient with Implantable Cardioverter Defibrillator (ICD and Posttraumatic stress disorder(PTSD.

    Directory of Open Access Journals (Sweden)

    Sahar Ansari

    2014-09-01

    Full Text Available The implantable cardioverter defibrillator (ICD has currently become the standard treatment for preventing sudden cardiac death. There are some psychological consequences in patients with ICD such as posttraumatic stress disorder (PTSD after the shocks induced by ICD. This report aimed to present the case of a 54-year-old man with ICD who had developed PTSD; his PTSD was treated, using cognitive-behavioral psychotherapy consisting of relaxation, mindfulness and problem solving techniques. In patients with ICD who are experiencing PTSD using cognitive behavioral interventions may be helpful to reduce their psychological sufferings.

  5. Monitoring treatment expectations in patients with an implantable cardioverter-defibrillator using the EXPECT-ICD scale

    DEFF Research Database (Denmark)

    Habibovic, Mirela; Pedersen, Susanne S.; van den Broek, Krista C

    2014-01-01

    AIMS: Patient treatment expectations may affect cardiac outcomes; however, till date, no validated instruments have been developed to monitor treatment expectations in patients with an implantable cardioverter-defibrillator (ICD). This study evaluates the predictive value of the newly developed 10...... with a two-factor model involving both negative (α = 0.84) and positive expectations (α = 0.77) with a score range of 0-20 for each factor. Negative treatment expectations were associated with higher levels of anxiety (β = 0.443; P ...-item EXPECtations Towards ICD therapy (EXPECT-ICD) in relation to anxiety, depression, and ICD related concerns 3 months post-implant.METHODS AND RESULTS: Consecutive implanted ICD patients were included as part of the WEB-based distress management programme for ICD patients (WEBCARE) trial from six...

  6. Optimal Implantable Cardioverter Defibrillator Programming.

    Science.gov (United States)

    Shah, Bindi K

    Optimal programming of implantable cardioverter defibrillators (ICDs) is essential to appropriately treat ventricular tachyarrhythmias and to avoid unnecessary and inappropriate shocks. There have been a series of large clinical trials evaluating tailored programming of ICDs. We reviewed the clinical trials evaluating ICD therapies and detection, and the consensus statement on ICD programming. In doing so, we found that prolonged ICD detection times, higher rate cutoffs, and antitachycardia pacing (ATP) programming decreases inappropriate and painful therapies in a primary prevention population. The use of supraventricular tachyarrhythmia discriminators can also decrease inappropriate shocks. Tailored ICD programming using the knowledge gained from recent ICD trials can decrease inappropriate and unnecessary ICD therapies and decrease mortality.

  7. Adherence to an Aerobic Exercise Intervention after an Implantable Cardioverter Defibrillator (ICD).

    Science.gov (United States)

    Dougherty, Cynthia M; Luttrell, Matilda N; Burr, Robert L; Kim, Misun; Haskell, William L

    2016-02-01

    Exercise adherence is an important element in achieving important exercise outcomes. The purpose of this study was to describe adherence in a home-based aerobic exercise program following an implantable cardioverter defibrillator (ICD), determine effects of adherence on peakVO2 , and outline reasons for nonadherence. A single-blind randomized control trial of home walking compared to usual care in 160 patients with an ICD for primary or secondary prevention was conducted. This report is on adherence in the exercise arm (N = 84). Home walking exercise consisted of 8 weeks of aerobic conditioning (60 minutes/day, 5 days/week) followed by 16 weeks of aerobic maintenance (150 minutes/week, 30 minutes/session) at 60-80% of heart rate reserve. Adherence was tracked using Polar heart rate (HR) monitors, pedometers, home exercise logs, and telephone follow-up. Adherence was defined as performing at least 80% of prescribed exercise. For aerobic conditioning, there was a mean frequency of 3.81 walks/week, duration of 1,873 minutes walked, and 17.5% of exercise was in the target HR (THR) zone. For aerobic maintenance, there was a mean frequency of 2.4 walks/week, duration of 1,872 minutes/walked, and 8.7% of exercise was in the THR zone. Those who were 80% adherent achieved a 3.4 mL/kg/min (P = 0.03) improvement in peakVO2 over those who were exercise ranged from scheduling issues to viral illness and fatigue. Adherence to aerobic exercise frequency and duration was high with few dropouts, resulting in higher peakVO2 . Exercise monitoring equipment encouraged adherence and conferred a sense of safety to exercise. ©2015 Wiley Periodicals, Inc.

  8. Gender differences in anxiety and concerns about the cardioverter defibrillator

    DEFF Research Database (Denmark)

    Spindler, Helle; Johansen, Jens B; Andersen, Kirsten Krogh

    2009-01-01

    Little is known about gender differences in the response to implantable cardioverter defibrillator (ICD) therapy. We compared female and male ICD patients on anxiety, depression, health-related quality of life (HRQL), ICD concerns, and ICD acceptance.......Little is known about gender differences in the response to implantable cardioverter defibrillator (ICD) therapy. We compared female and male ICD patients on anxiety, depression, health-related quality of life (HRQL), ICD concerns, and ICD acceptance....

  9. The NO Regular Defibrillation testing In Cardioverter Defibrillator Implantation (NORDIC ICD) trial

    DEFF Research Database (Denmark)

    Bänsch, Dietmar; Bonnemeier, Hendrik; Brandt, Johan

    2015-01-01

    was standardized across all participating centres. After inducing a fast ventricular tachycardia (VT) with a heart rate ≥240 b.p.m. or ventricular fibrillation (VF) with a low-energy T-wave shock, DF was attempted with an initial 15 J shock. If the shock reversed the VT or VF, DF testing was considered successful...... and terminated. If unsuccessful, two effective 24 J shocks were administered. If DF was unsuccessful, the system was reconfigured and another DF testing was performed. An ICD shock energy of 40 J had to be programmed in all patients for treatment of spontaneous VT/VF episodes. The primary endpoint...

  10. The NO Regular Defibrillation testing In Cardioverter Defibrillator Implantation (NORDIC ICD) trial: concept and design of a randomized, controlled trial of intra-operative defibrillation testing during de novo defibrillator implantation.

    Science.gov (United States)

    Bänsch, Dietmar; Bonnemeier, Hendrik; Brandt, Johan; Bode, Frank; Svendsen, Jesper Hastrup; Felk, Angelika; Hauser, Tino; Wegscheider, Karl

    2015-01-01

    Although defibrillation (DF) testing is still considered a standard procedure during implantable cardioverter-defibrillator (ICD) insertion and has been an essential element of all trials that demonstrated the survival benefit of ICD therapy, there are no large randomized clinical trials demonstrating that DF testing improves clinical outcome and if the outcome would remain the same by omitting DF testing. Between February 2011 and July 2013, we randomly assigned 1077 patients to ICD implantation with (n = 540) or without (n = 537) DF testing. The intra-operative DF testing was standardized across all participating centres. After inducing a fast ventricular tachycardia (VT) with a heart rate ≥240 b.p.m. or ventricular fibrillation (VF) with a low-energy T-wave shock, DF was attempted with an initial 15 J shock. If the shock reversed the VT or VF, DF testing was considered successful and terminated. If unsuccessful, two effective 24 J shocks were administered. If DF was unsuccessful, the system was reconfigured and another DF testing was performed. An ICD shock energy of 40 J had to be programmed in all patients for treatment of spontaneous VT/VF episodes. The primary endpoint was the average efficacy of the first ICD shock for all true VT/VF episodes in each patient during follow-up. The secondary endpoints included the frequency of system revisions, total fluoroscopy, implantation time, procedural serious adverse events, and all-cause, cardiac, and arrhythmic mortality during follow-up. Home Monitoring was used in all patients to continuously monitor the system integrity, device programming and performance. The NO Regular Defibrillation testing In Cardioverter Defibrillator Implantation (NORDIC ICD) trial is one of two large prospective randomized trials assessing the effect of DF testing omission during ICD implantation. NCT01282918. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email

  11. Concerns about the implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van Domburg, Ron T; Theuns, Dominic A M J

    2005-01-01

    Patients with an implantable cardioverter defibrillator (ICD) are at increased risk of anxiety disorders. In turn, anxiety has been identified as a precipitant of ventricular arrhythmias. Anxiety may in part be attributed to concerns about the ICD firing, but the relationship between ICD concerns......, psychological morbidity, and shocks has not been systematically investigated. We examined the relative importance of experienced shocks versus subjective concerns about the ICD as determinants of anxiety and depressive symptoms in ICD patients....

  12. Implantable cardioverter defibrillator implantation in children in The Netherlands

    NARCIS (Netherlands)

    Ten Harkel, ADJ; Blom, NA; Reimer, AG; Tukkie, R; Sreeram, N; Bink-Boelkens, MTE

    To evaluate the indications, underlying cardiac disorders, efficacy and complications involved with implantable cardioverter-defibrillators (ICDs) in paediatric patients in The Netherlands, the records of all patients aged 18 years or younger who underwent ICD placement were reviewed

  13. Implantable cardioverter defibrillator implantation in children in The Netherlands

    NARCIS (Netherlands)

    ten Harkel, A. Derk Jan; Blom, Nico A.; Reimer, Annette G.; Tukkie, Raymond; Sreeram, Narayanswami; Bink-Boelkens, Margreet T. E.

    2005-01-01

    To evaluate the indications, underlying cardiac disorders, efficacy and complications involved with implantable cardioverter-defibrillators (ICDs) in paediatric patients in The Netherlands, the records of all patients aged 18 years or younger who underwent ICD placement were reviewed

  14. Results of ENHANCED Implantable Cardioverter Defibrillator Programming to Reduce Therapies and Improve Quality of Life (from the ENHANCED-ICD Study)

    DEFF Research Database (Denmark)

    Mastenbroek, Mirjam H.; Pedersen, Susanne S.; van der Tweel, Ingeborg

    2016-01-01

    -reported outcomes. The "ENHANCED Implantable Cardioverter Defibrillator programming to reduce therapies and improve quality of life" study (ENHANCED-ICD study) was a prospective, safety-monitoring study enrolling 60 primary and secondary prevention patients at the University Medical Center Utrecht. Patients...... programming strategy, unnecessary ICD therapy was prevented in 10% of ENHANCED-ICD patients during a median follow-up period of 1.3 years. With respect to patient-reported outcomes, levels of distress were highest and perceived health status lowest at the time of implantation, which both gradually improved...... during follow-up. In conclusion, the ENHANCED-ICD study demonstrates that programming a NID 60/80 for VT/VF detection is safe for ICD patients and does not negatively impact their quality of life....

  15. Methodological limitations of psychosocial interventions in patients with an implantable cardioverter-defibrillator (ICD A systematic review

    Directory of Open Access Journals (Sweden)

    Ockene Ira S

    2009-12-01

    Full Text Available Abstract Background Despite the potentially life-saving benefits of the implantable cardioverter-defibrillator (ICD, a significant group of patients experiences emotional distress after ICD implantation. Different psychosocial interventions have been employed to improve this condition, but previous reviews have suggested that methodological issues may limit the validity of such interventions. Aim: To review the methodology of previously published studies of psychosocial interventions in ICD patients, according to CONSORT statement guidelines for non-pharmacological interventions, and provide recommendations for future research. Methods We electronically searched the PubMed, PsycInfo and Cochrane databases. To be included, studies needed to be published in a peer-reviewed journal between 1980 and 2008, to involve a human population aged 18+ years and to have an experimental design. Results Twelve studies met the eligibility criteria. Samples were generally small. Interventions were very heterogeneous; most studies used cognitive behavioural therapy (CBT and exercise programs either as unique interventions or as part of a multi-component program. Overall, studies showed a favourable effect on anxiety (6/9 and depression (4/8. CBT appeared to be the most effective intervention. There was no effect on the number of shocks and arrhythmic events, probably because studies were not powered to detect such an effect. Physical functioning improved in the three studies evaluating this outcome. Lack of information about the indication for ICD implantation (primary vs. secondary prevention, limited or no information regarding use of anti-arrhythmic (9/12 and psychotropic (10/12 treatment, lack of assessments of providers' treatment fidelity (12/12 and patients' adherence to the intervention (11/12 were the most common methodological limitations. Conclusions Overall, this review supports preliminary evidence of a positive effect of psychosocial interventions

  16. The Screen-ICD trial. Screening for anxiety and cognitive therapy intervention for patients with implanted cardioverter defibrillator (ICD)

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Herning, Margrethe; Svendsen, Jesper Hastrup

    2016-01-01

    by Structured Clinical Interview for DSM Disorders (SCID). (3) Investigator-initiated randomised clinical superiority trial with blinded outcome assessment, with 1:1 randomisation to cognitive–behavioural therapy (CBT) performed by a cardiac nurse with CBT training, plus usual care or usual care alone...... of starting relevant intervention. Methods and analysis: Screen-ICD consists of 3 parts: (1) screening of all hospitalised and outpatient patients at two university hospitals using the Hospital Anxiety and Depression Scale (HADS), scores ≥8 are invited to participate. (2) Assessment of type of anxiety...

  17. Pre-implantation implantable cardioverter defibrillator concerns and Type D personality increase the risk of mortality in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van den Broek, Krista C; Erdman, Ruud A M

    2010-01-01

    Little is known about the influence of psychological factors on prognosis in implantable cardioverter defibrillator (ICD) patients. We examined the influence of the distressed personality (Type D) and pre-implantation device concerns on short-term mortality in ICD patients.......Little is known about the influence of psychological factors on prognosis in implantable cardioverter defibrillator (ICD) patients. We examined the influence of the distressed personality (Type D) and pre-implantation device concerns on short-term mortality in ICD patients....

  18. Somatosensory amplification mediates sex differences in psychological distress among cardioverter-defibrillator patients

    DEFF Research Database (Denmark)

    Versteeg, Henneke; Baumert, Jens; Kolb, Christof

    2010-01-01

    The present study examined whether female patients with an implantable cardioverter defibrillator (ICD) report more psychological distress than male patients, and whether somatosensory amplification mediates this relationship. Design: Consecutive ICD patients (N = 241; 33% women) participating in...

  19. Contemporary rates and outcomes of single- vs. dual-coil implantable cardioverter defibrillator lead implantation: data from the Israeli ICD Registry.

    Science.gov (United States)

    Leshem, Eran; Suleiman, Mahmoud; Laish-Farkash, Avishag; Konstantino, Yuval; Glikson, Michael; Barsheshet, Alon; Goldenberg, Ilan; Michowitz, Yoav

    2017-09-01

    Dual-coil leads were traditionally considered standard of care due to lower defibrillation thresholds (DFT). Higher complication rates during extraction with parallel progression in implantable cardioverter defibrillator (ICD) technology raised questions on dual coil necessity. Prior substudies found no significant outcome difference between dual and single coils, although using higher rates of DFT testing then currently practiced. We evaluated the temporal trends in implantation rates of single- vs. dual-coil leads and determined the associated adverse clinical outcomes, using a contemporary nation-wide ICD registry. Between July 2010 and March 2015, 6343 consecutive ICD (n = 3998) or CRT-D (n = 2345) implantation patients were prospectively enrolled in the Israeli ICD Registry. A follow-up of at least 1 year of 2285 patients was available for outcome analysis. The primary endpoint was all-cause mortality. Single-coil leads were implanted in 32% of our cohort, 36% among ICD recipients, and 26% among CRT-D recipients. Secondary prevention indication was associated with an increased rate of dual-coil implantation. A significant decline in dual-coil leads with reciprocal incline of single coils was observed, despite low rates of DFT testing (11.6%) during implantation, which also declined from 31 to 2%. In the multivariate Cox model analysis, dual- vs. single-coil lead implantation was not associated with an increased risk of mortality [hazard ratio (HR) = 1.23; P= 0.33], heart failure hospitalization (HR = 1.34; P=0.13), appropriate (HR = 1.25; P= 0.33), or inappropriate ICD therapy (HR = 2.07; P= 0.12). Real-life rates of single-coil lead implantation are rising while adding no additional risk. These results of single-coil safety are reassuring and obtained, despite low and contemporary rates of DFT testing. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  20. Intra-operative defibrillation testing and clinical shock efficacy in patients with implantable cardioverter-defibrillators

    DEFF Research Database (Denmark)

    Bänsch, Dietmar; Bonnemeier, Hendrik; Brandt, Johan

    2015-01-01

    AIMS: This trial was designed to test the hypothesis that shock efficacy during follow-up is not impaired in patients implanted without defibrillation (DF) testing during first implantable cardioverter-defibrillator (ICD) implantation. METHODS AND RESULTS: Between February 2011 and July 2013, 107...

  1. Implantable Cardioverter Defibrillator

    Science.gov (United States)

    ... interfere with an ICD include: Cell phones and MP3 players (for example, iPods) Household appliances, such as ... experts recommend not putting your cell phone or MP3 player in a shirt pocket over your ICD ( ...

  2. Manual for the psychotherapeutic treatment of acute and post-traumatic stress disorders following multiple shocks from implantable cardioverter defibrillator (ICD).

    Science.gov (United States)

    Jordan, Jochen; Titscher, Georg; Peregrinova, Ludmila; Kirsch, Holger

    2013-01-01

    In view of the increasing number of implanted cardioverter defibrillators (ICD), the number of people suffering from so-called "multiple ICD shocks" is also increasing. The delivery of more than five shocks (appropriate or inappropriate) in 12 months or three or more shocks (so called multiple shocks) in a short time period (24 hours) leads to an increasing number of patients suffering from severe psychological distress (anxiety disorder, panic disorder, adjustment disorder, post-traumatic stress disorder). Untreated persons show chronic disease processes and a low rate of spontaneous remission and have an increased morbidity and mortality. Few papers have been published concerning the psychotherapeutic treatment for these patients. The aim of this study is to develop a psychotherapeutic treatment for patients with a post-traumatic stress disorder or adjustment disorder after multiple ICD shocks. Explorative feasibility study: Treatment of 22 patients as a natural design without randomisation and without control group. The period of recruitment was three years, from March 2007 to March 2010. The study consisted of two phases: in the first phase (pilot study) we tested different components and dosages of psychotherapeutic treatments. The final intervention programme is presented in this paper. In the second phase (follow-up study) we assessed the residual post-traumatic stress symptoms in these ICD patients. The time between treatment and follow-up measurement was 12 to 30 months. Thirty-one patients were assigned to the Department of Psychocardiology after multiple shocks. The sample consisted of 22 patients who had a post-traumatic stress disorder or an adjustment disorder and were willing and able to participate. They were invited for psychological treatment. 18 of them could be included into the follow-up study. After the clinical assessment at the beginning and at the end of the inpatient treatment a post-treatment assessment with questionnaires followed. In

  3. Behavioral interventions in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; Burg, Matthew M; Pedersen, Susanne S.

    2013-01-01

    The implantable cardioverter defibrillator (ICD) is the first-line treatment for primary and secondary prevention of sudden cardiac death. A subgroup of patients experience psychological distress postimplant, and no clear evidence base exists regarding how best to address patients' needs. The aim...... of this critical review is to provide an overview of behavioral interventions in ICD patients to date, and to delineate directions for future research using lessons learned from the ongoing RISTA and WEBCARE trials....

  4. Psychological distress in patients with an implantable cardioverter defibrillator

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Shiga, MD

    2013-12-01

    Full Text Available Despite the effectiveness of an implantable cardioverter defibrillator (ICD, its implantation and concomitant therapies, including shocks, can induce psychological distress in patients. Depression has been observed in approximately 30% of ICD patients, and shocks may contribute to the persistence of depression. Anxiety is common, with reports of 24–87% of ICD patients experiencing symptoms of anxiety after implantation, and type D personality and ICD-related concerns may play important roles in the level of anxiety in ICD patients. However, the association between ICD shocks and anxiety is controversial. The prevalence of posttraumatic stress disorder (PTSD in ICD patients is approximately 20%, and type D personality, comorbidities, and frequent shocks may contribute to PTSD. It is also important to pay attention to the psychological distress in the partners of ICD patients.

  5. Making post-mortem implantable cardioverter defibrillator explantation safe

    DEFF Research Database (Denmark)

    Räder, Sune B E W; Zeijlemaker, Volkert; Pehrson, Steen

    2009-01-01

    that the resting voltage over the operating person would not exceed 50 V. CONCLUSION: The use of intact medical gloves made of latex, neoprene, or plastic eliminates the potential electrical risk during explantation of an ICD. Two gloves on each hand offer sufficient protection. We will recommend the use......AIMS: The aim of this study is to investigate whether protection with rubber or plastic gloves during post-mortem explantation of an implantable cardioverter defibrillator (ICD) offers enough protection for the explanting operator during a worst-case scenario (i.e. ICD shock). METHODS AND RESULTS...

  6. Clinical safety of an MRI conditional implantable cardioverter defibrillator system: A prospective Monocenter ICD-Magnetic resonance Imaging feasibility study (MIMI).

    Science.gov (United States)

    Kypta, Alexander; Blessberger, Hermann; Hoenig, Simon; Saleh, Karim; Lambert, Thomas; Kammler, Juergen; Fellner, Franz; Lichtenauer, Michael; Steinwender, Clemens

    2016-03-01

    The aim of this study was to evaluate the safety and efficacy of the Lumax 740(®) Implantable Cardioverter Defibrillator (ICD) system in patients undergoing a defined 1.5 Tesla (T) MRI. Between November 2013 and April 2014, eighteen patients (age range, 41-78 years; mean age, 64 years) implanted with a Lumax 740(®) ICD system for at least 6 weeks before an MRI were enrolled into this single-center feasibility study. The local ethics committee approved the study before patients gave written informed consent. Patients underwent defined MRI 1.5T of the brain and lower lumbar spine with three safety follow-up evaluations obtained during the 3-month study period. Data were analyzed descriptively. Study endpoints were the absence of either MRI and pacing system related serious adverse device effects (SADE), or of a ventricular pacing threshold increase >0.5V, or of an R-wave amplitude attenuation battery status. Sixteen patients completed the MRI and the follow-up period. As no SADE occurred, the SADE free rate was 100%. Freedom from ventricular pacing threshold increase was 100% (16/16; 95%CI: 82.9%; 100.0%). There were no significant differences between baseline and follow-up measurements of sensing amplitudes (-0.58 ± 2.07 mV, P = 0.239, -0.41 ± 1.04 mV, P = 0.133, and -0.25 ± 1.36 mV, P = 0.724, for immediately after, 1 month and 3 months after MRI scan, respectively) and pacing thresholds (-0.047 ± 0.18 V, P = 0.317, -0.019 ± 0.11 V, P = 0.490, and 0.075 ± 0.19 V, P = 0.070, for immediately after, 1 month and 3 months after MRI scan, respectively). Lead impedances after the MRI scan were significantly lower as compared with baseline values (-22.8 ± 21.69 Ω, P = 0.001, -21.62 ± 39.71 Ω, P = 0.040, and -33.68 ± 57.73 Ω, P = 0.018, for immediately after, 1 month and 3 months after MRI scan, respectively). MRI scans in patients with MRI conditional ICD system (Lumax 740(

  7. Attrition and Adherence in a Web-Based Distress Management Program for Implantable Cardioverter Defibrillator Patients (WEBCARE): Randomized Controlled Trial

    DEFF Research Database (Denmark)

    Habibovic, M.; Cuijpers, P.; Alings, M.

    2014-01-01

    Background: WEB-Based Distress Management Program for Implantable CARdioverter defibrillator Patients (WEBCARE) is a Web-based randomized controlled trial, designed to improve psychological well-being in patients with an implantable cardioverter defibrillator (ICD). As in other Web-based trials, ...

  8. Implantable cardioverter defibrillator specific rehabilitation improves health cost outcomes

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Zwisler, Ann-Dorthe; Koch, Mette Bjerrum

    2015-01-01

    OBJECTIVE: The Copenhagen Outpatient ProgrammE - implantable cardioverter defibrillator (COPE-ICD) trial included patients with implantable cardioverter defibrillators in a randomized controlled trial of rehabilitation. After 6-12 months significant differences were found in favour of the rehabil...... was -6,789 USD/-5,593 Euro in favour of rehabilitation. CONCLUSION: No long-term health outcome benefits were found for the rehabilitation programme. However, the rehabilitation programme resulted in a reduction in total attributable direct costs....... of the rehabilitation group for exercise capacity, general and mental health. The aim of this paper is to explore the long-term health effects and cost implications associated with the rehabilitation programme; more specifically, (i) to compare implantable cardioverter defibrillator therapy history and mortality...... between rehabilitation and usual care groups; (ii) to examine the difference between rehabilitation and usual care groups in terms of time to first admission; and (iii) to determine attributable direct costs. METHODS: Patients with first-time implantable cardioverter defibrillator implantation (n = 196...

  9. Symptomatic heart failure is the most important clinical correlate of impaired quality of life, anxiety, and depression in implantable cardioverter-defibrillator patients

    DEFF Research Database (Denmark)

    Johansen, Jens B; Pedersen, Susanne S.; Spindler, Helle

    2008-01-01

    To identify correlates of impaired quality of life (QOL), anxiety, and depression in patients with an implantable cardioverter-defibrillator (ICD).......To identify correlates of impaired quality of life (QOL), anxiety, and depression in patients with an implantable cardioverter-defibrillator (ICD)....

  10. E-Health to Manage Distress in Patients With an Implantable Cardioverter-Defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; Denollet, Johan; Cuijpers, Pim

    2014-01-01

    UNLABELLED: The Web-based distress management program for patients with an implantable cardioverter-defibrillator (ICD; WEBCARE) was developed to mitigate distress and enhance health-related quality of life in ICD patients. This study investigated the treatment effectiveness at 3-month follow-up ...

  11. Implantable cardioverter defibrillator therapy for prevention of sudden cardiac death in children in the Netherlands

    NARCIS (Netherlands)

    Heersche, Jogien H. M.; Blom, Nico A.; van de Heuvel, Freek; Blank, Christiaan; Reimer, Annette G.; Clur, Sally-Ann; Witsenburg, Maarten; ten Harkel, A. Derk Jan

    2010-01-01

    INTRODUCTION: Implantable cardioverter defibrillator (ICD) therapy is increasingly used in children. The purpose of this multicenter study is to evaluate mid-term clinical outcome and to identify predictors for device discharge in pediatric ICD recipients. METHODS AND RESULTS: From 1995 to 2006, 45

  12. Implantable Cardioverter Defibrillator Therapy for Prevention of Sudden Cardiac Death in Children in The Netherlands

    NARCIS (Netherlands)

    Heersche, Jogien H. M.; Blom, Nico A.; Van De Heuvel, Freek; Blank, Christiaan; Reimer, Annette G.; Clur, Sally-Ann; Witsenburg, Maarten; Ten Harkel, A. Derk Jan

    Introduction: Implantable cardioverter defibrillator (ICD) therapy is increasingly used in children. The purpose of this multicenter study is to evaluate mid-term clinical outcome and to identify predictors for device discharge in pediatric ICD recipients. Methods and Results: From 1995 to 2006, 45

  13. Increased anxiety in partners of patients with a cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; VAN DEN Berg, Martha; Erdman, Ruud A M

    2009-01-01

    The partner of the implantable cardioverter-defibrillator (ICD) patient serves as an important source of support for the patient, which may be hampered if the partner experiences increased distress. We examined (1) potential differences in anxiety and depressive symptoms in ICD patients compared...

  14. Anxiety and risk of ventricular arrhythmias or mortality in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; Pedersen, Susanne S.; van den Broek, Krista C

    2013-01-01

    A subgroup of patients with an implantable cardioverter defibrillator (ICD) experiences anxiety after device implantation. The purpose of the present study was to evaluate whether anxiety is predictive of ventricular arrhythmias and all-cause mortality 1 year post ICD implantation....

  15. Ventricular Tachyarrhythmias and Mortality in Patients With an Implantable Cardioverter Defibrillator

    DEFF Research Database (Denmark)

    Mastenbroek, Mirjam H; Versteeg, Henneke; Jordaens, Luc

    2014-01-01

    Objective We examined whether depression is independently associated with implantable cardioverter defibrillator (ICD) therapy for ventricular tachyarrhythmias and mortality. Methods A cohort of 430 consecutive patients with a first-time ICD (79% men; mean [standard deviation] age = 57.8 [12.1] y...

  16. Depressive symptoms in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S; Andersen, Christina M; Denollet, Johan

    2018-01-01

    OBJECTIVE: Patients with an implantable cardioverter defibrillator (ICD) and co-morbid depression are at greater risk of poor quality of life and premature death. We examined if treatment expectations predict depressive symptoms 12months post implant. METHODS: First-time implant patients from...... of 12-months depressive symptoms: Model 1: Negative treatment expectations (β=0.202; p=0.020) and baseline depression (β=0.376; pdepression (β=0.350; p....051). Model 3: Baseline depression (β=0.353; p

  17. Azygos Vein Lead Implantation For High Defibrillation Thresholds In Implantable Cardioverter Defibrillator Placement

    Directory of Open Access Journals (Sweden)

    Naga VA Kommuri

    2010-01-01

    Full Text Available Evaluation of defibrillation threshold is a standard of care during implantation of implantable cardioverter defibrillator. High defibrillation thresholds are often encountered and pose a challenge to electrophysiologists to improve the defibrillation threshold. We describe a case series where defibrillation thresholds were improved after implanting a defibrillation lead in the azygos vein.

  18. Spinal cord stimulation for refractory angina in patients implanted with cardioverter defibrillators: five case reports

    DEFF Research Database (Denmark)

    Enggaard, Thomas P; Andersen, Claus; Scherer, Christian

    2010-01-01

    Patients implanted with a cardioverter defibrillator (ICD) who are suffering from refractory angina pectoris could benefit from spinal cord stimulation (SCS) due to the well-documented pain relieving effect. However, the combined treatment remains controversial. The aim of the study is to report...... successful long-term treatment with SCS in five patients implanted with cardioverter defibrillators. The combined treatments with ICD and thoracic epidural electrical stimulation were used in five patients with refractory angina pectoris. During the procedure of the implantation, testing with the maximal...... for refractory angina pectoris can be performed in patients implanted with cardioverter defibrillators without interference. However, individual testing during implantation or re-programming the devices is mandatory in order to assess optimal safety in each patient....

  19. Monitoring device acceptance in implantable cardioverter defibrillator patients using the Florida Patient Acceptance Survey

    DEFF Research Database (Denmark)

    Versteeg, Henneke; Starrenburg, Annemieke; Denollet, Johan

    2012-01-01

    Patient device acceptance might be essential in identifying patients at risk for adverse patient-reported outcomes following implantation of an implantable cardioverter defibrillator (ICD). We examined the validity and reliability of the Florida Patient Acceptance Scale (FPAS) and identified corr...

  20. Gender disparities in anxiety and quality of life in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; van den Broek, Krista C; Theuns, Dominic A M J

    2011-01-01

    A paucity of studies in implantable cardioverter-defibrillator (ICD) patients has examined gender disparities in patient-reported outcomes, such as anxiety and quality of life (QoL). We investigated (i) gender disparities in anxiety and QoL and (ii) the magnitude of the effect of gender vs. New...

  1. SUDDEN CARDIAC DEATH AND THE USE OF IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS IN PEDIATRIC-PATIENTS

    NARCIS (Netherlands)

    SILKA, MJ; KRON, J; DUNNIGAN, A; DICK, M; BINKBOELKENS, M; ERICKSON, CC; JEDEIKIN, R; WETZEL, GT; VANHARE, GF; CAMPBELL, R; WALSH, E; SAUL, JP; SCHAFFER, MS; KARPAWICH, P; VOGEL, RL; BENSON, DW; DEAL, B; SCAGLIOTTI, D; STERBA, R; HORDOF, AJ; KRONGRAD, E; KANTER, RJ; EPSTEIN, M; COHEN, M; BEDER, S; HAMILTON, R; FOURNIER, A; HUBBARD, J; CHRISTIANSEN, JL; JENNINGS, J; VILLAFANE, J; PORTER, CBJ; CASE, C; GILLETTE, PC; BELAND, M; KUGLER, JD; OCONNOR, BK; ALLENDER, H; HERNDON, SP; SMITH, RT; BURTON, D; KURER, CC; BYRUM, C; GUAM, WE; FRIEDMAN, R; PERRY, JC; SCOTT, W; MEHTA, AV; PICKHOFF, AS; FISH, F; YEAGER, S; KAWABORI, [No Value; TRIPPLE, M; ROSENFELD, LE

    Background. During the past decade. the implantable cardioverter-defibrillator (ICD) has emerged as the primary therapeutic option for survivors of sudden cardiac death (SCD). Investigation of the clinical efficacy of these devices has primarily assessed outcome in adults with coronary artery

  2. Undertreatment of anxiety and depression in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Kupper, Nina; Theuns, Dominic A M J

    2012-01-01

    Twenty-five to 33% of patients with an implantable cardioverter-defibrillator (ICD) experience anxiety and depression, but it is not known whether their symptoms are adequately treated. We investigated (a) whether patients with clinically relevant symptoms of distress received appropriate treatme......, and (b) whether patients not treated for their emotional distress reported poorer health status using a prospective study design....

  3. Experiences of patients with implantable cardioverter defibrillator in Turkey: A qualitative study

    Directory of Open Access Journals (Sweden)

    Özgür Aslan

    2012-01-01

    Full Text Available Background. There has been an increase in the number of patients with implantable cardioverter defibrillator (ICD. It isimportant to understand ICD patients’ experiences with it.Aim. The aim of this study was to describe experiences of patients with implantable cardioverter defibrillator (ICD.Methodology. A qualitative approach was used. Focus group interviews were used to obtain data from 19 patients whowere implanted cardioverter defibrillator at two centers in Izmir, Turkey. The patients were assigned into four groups. Thedata was analyzed using qualitative content analysis.Results. The analysis revealed six main themes: activities of daily living, social life, familial relationships, emotionalchanges, implantable cardioverter defibrillator shocks and experiences with receiving information and counselling fromhealth care providers.Conclusions. It can be concluded that patients with ICD experience physical and psychological problems and are not offeredthe education they need. To reduce the fears of the patients and their families and to prepare them for possible life stylechanges, comprehensive training programs that start in the pre-implantation period and continue into the post-implantationperiod should be organized.

  4. Higher defibrillation threshold in methamphetamine cardiomyopathy patients with implantable cardioverter-defibrillator

    Directory of Open Access Journals (Sweden)

    Rakesh Malhotra

    2017-11-01

    Full Text Available Introduction: Identification of patients with an increased risk of high defibrillation thresholds (DFTs is important in planning implantable cardioverter-defibrillator (ICD procedures. Clinical observations have suggested that patients with methamphetamine cardiomyopathy (MACMP have significantly elevated defibrillation thresholds. We hypothesized that MACMP patients would have higher DFT thresholds than controls and would require procedural changes during ICD implantation to accommodate higher thresholds. Methods: We identified consecutive patients with MACMP undergoing ICD implantation at the academic center from 2003 to 2007. We then compared DFTs against age-and sex-matched controls. Results: The MACMP (n = 10 group showed significantly increased DFT thresholds (23.7 ± 6.7 J compared with age and sex-matched controls (14.5 ± 4.6 J, p < 0.005. Additionally, patients with MACMP had evidence of more severe congestive heart failure, with increased B-type natrieutic protein (BNP levels (1173 ± 784 vs 260 ± 349, p = 0.02 and decreased left ventricular ejection fraction (LVEF (17.8 ± 9.4 vs 35.9 ± 15.2, p = 0.02. MACMP patients required high output devices than controls (50% versus 0%, p = 0.03. Differences between groups remained significant despite adjusting for LVEF. Conclusions: Planning for ICD implantation should take into consideration a history of methamphetamine abuse, mandating DFT testing and empiric consideration of high output devices for such patients. Keywords: Methamphetamine cardiomyopathy, Implantable cardioverter-defibrillatior, Defibrillation threshold testing, B-type natriuretic peptide, Ejection fraction

  5. Battery longevity in cardiac resynchronization therapy implantable cardioverter defibrillators.

    Science.gov (United States)

    Alam, Mian Bilal; Munir, Muhammad Bilal; Rattan, Rohit; Flanigan, Susan; Adelstein, Evan; Jain, Sandeep; Saba, Samir

    2014-02-01

    Cardiac resynchronization therapy (CRT) implantable cardioverter defibrillators (ICDs) deliver high burden ventricular pacing to heart failure patients, which has a significant effect on battery longevity. The aim of this study was to investigate whether battery longevity is comparable for CRT-ICDs from different manufacturers in a contemporary cohort of patients. All the CRT-ICDs implanted at our institution from 1 January 2008 to 31 December 2010 were included in this analysis. Baseline demographic and clinical data were collected on all patients using the electronic medical record. Detailed device information was collected on all patients from scanned device printouts obtained during routine follow-up. The primary endpoint was device replacement for battery reaching the elective replacement indicator (ERI). A total of 646 patients (age 69 ± 13 years), implanted with CRT-ICDs (Boston Scientific 173, Medtronic 416, and St Jude Medical 57) were included in this analysis. During 2.7 ± 1.5 years follow-up, 113 (17%) devices had reached ERI (Boston scientific 4%, Medtronic 25%, and St Jude Medical 7%, P battery was significantly worse for Medtronic devices compared with devices from other manufacturers (94% for Boston scientific, 67% for Medtronic, and 92% for St Jude Medical, P battery longevity by manufacturer was independent of pacing burden, lead parameters, and burden of ICD therapy. There are significant discrepancies in CRT-ICD battery longevity by manufacturer. These data have important implications on clinical practice and patient outcomes.

  6. Clinical performance of different DF-4 implantable cardioverter defibrillator leads.

    Science.gov (United States)

    Sarrazin, Jean-François; Philippon, François; Sellier, Romain; André, Philippe; O'Hara, Gilles; Molin, Franck; Nault, Isabelle; Blier, Louis; Champagne, Jean

    2018-06-01

    Implantable cardioverter-defibrillator (ICD) DF-4 connectors have been introduced to facilitate defibrillator lead connection and to reduce the size of device header. There are limited data regarding the overall performance of those leads and no comparison between different ICD DF-4 leads. This is a cohort study of consecutive patients implanted with ICD DF-4 lead system at one University Centre between October 2010 and February 2015. A historical control group of patients with ICD DF-1 lead implantation was used for comparison. The following ICD DF-4 leads were evaluated: St. Jude Medical Durata 7122Q (St. Jude Medical, St. Paul, MN, USA), Medtronic Sprint Quattro Secure 6935 M (Medtronic Inc., Minneapolis, MN, USA), Boston Scientific Endotak Reliance 4-Site 0293 (Boston Scientific, Marlborough, MA, USA), and Boston Scientific Reliance 4-Front 0693. This study evaluated the acute and mid-term performances of those leads as well as complications. A total of 812 patients (age 63 ± 12 years, 80% male, left ventricular ejection fraction 31 ± 12%) underwent implantation of an ICD DF-4 lead. Acute and follow-up R-wave sensing and threshold were excellent. Compared to implantation, intrinsic R waves were higher at follow-up for Boston Scientific and Medtronic leads, and pacing lead impedances were lower for all leads at first follow-up (P < 0.001). The number of lead dislodgement or failure was similar between all leads. The estimated lead survival rates at 3 years were 95.6% for Boston Scientific Endotak 4-Site, 97.1% for Boston Scientific 4-Front, 97.7% for Medtronic Sprint Quattro, and 97.5% for St. Jude Durata (P  =  0.553). All ICD DF-4 leads had excellent acute and mid-term electrical performances. Longer follow-up will be necessary to confirm their sustained performance. © 2018 Wiley Periodicals, Inc.

  7. Dutch outcome in implantable cardioverter-defibrillator therapy (DO-IT) : Registry design and baseline characteristics of a prospective observational cohort study to predict appropriate indication for implantable cardioverter-defibrillator

    NARCIS (Netherlands)

    Van Barreveld, M. (M.); M.G.W. Dijkgraaf (Marcel); Hulleman, M. (M.); L. Boersma (Lucas); P.P.H.M. Delnoy (Peter Paul); M. Meine (Mathias); Tuinenburg, A.E. (A. E.); D.A.M.J. Theuns (Dominic); P. van der Voort (Pepijn); G-J.P. Kimman (Geert-Jan); E. Buskens (Erik); Tijssen, J.P.G. (J. P.G.); Bruinsma, N. (N.); Verstraelen, T.E. (T. E.); A.H. Zwinderman (Ailko); Van Dessel, P.H.F.M. (P. H.F.M.); A.A.M. Wilde (Arthur)

    2017-01-01

    textabstractBackground Implantable cardioverter-defibrillators (ICDs) are widely used for the prevention of sudden cardiac death. At present, both clinical benefit and cost-effectiveness of ICD therapy in primary prevention patients are topics of discussion, as only a minority of these patients will

  8. "Pseudo" Faraday cage: a solution for telemetry link interaction between a left ventricular assist device and an implantable cardioverter defibrillator.

    Science.gov (United States)

    Jacob, Sony; Cherian, Prasad K; Ghumman, Waqas S; Das, Mithilesh K

    2010-09-01

    Patients implanted with left ventricular assist devices (LVAD) may have implantable cardioverter defibrillators (ICD) implanted for sudden cardiac death prevention. This opens the possibility of device-device communication interactions and thus interferences. We present a case of such interaction that led to ICD communication failure following the activation of an LVAD. In this paper, we describe a practical solution to circumvent the communication interference and review the communication links of ICDs and possible mechanisms of ICD-LVAD interactions.

  9. Device orientation of a leadless pacemaker and subcutaneous implantable cardioverter-defibrillator in canine and human subjects and the effect on intrabody communication

    NARCIS (Netherlands)

    Quast, Anne-Floor B. E.; Tjong, Fleur V. Y.; Koop, Brendan E.; Wilde, Arthur A. M.; Knops, Reinoud E.; Burke, Martin C.

    2018-01-01

    The development of communicating modular cardiac rhythm management systems relies on effective intrabody communication between a subcutaneous implantable cardioverter-defibrillator (S-ICD) and a leadless pacemaker (LP), using conducted communication. Communication success is affected by the LP and

  10. Type D personality is associated with increased anxiety and depressive symptoms in patients with an implantable cardioverter defibrillator and their partners

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van Domburg, Ron T; Theuns, Dominic A M J

    2014-01-01

    We investigated the prevalence of anxiety and depressive symptoms in patients with an implantable cardioverter defibrillator (ICD) and their partners, and the role of personality factors and social support as determinants of distress....

  11. The use of guideline recommended beta-blocker therapy in primary prevention implantable cardioverter defibrillator patients

    DEFF Research Database (Denmark)

    Ruwald, Anne Christine; Gislason, Gunnar Hilmar; Vinther, Michael

    2017-01-01

    Aims: We aimed to examine the use of guideline recommended beta-blocker therapy prior to and after primary prevention implantable cardioverter defibrillator (ICD) implantation in a 'real-life' setting. Methods and results: From the Danish Pacemaker and ICD Registry we identified all 1st-time prim......Aims: We aimed to examine the use of guideline recommended beta-blocker therapy prior to and after primary prevention implantable cardioverter defibrillator (ICD) implantation in a 'real-life' setting. Methods and results: From the Danish Pacemaker and ICD Registry we identified all 1st......-time primary prevention ICD and cardiac resynchronization therapy defibrillator (CRT-D) implantations in Denmark from 2007-12 (n = 2935). Use of beta-blocker, type and dose was acquired through the Danish Prescription Registry. According to guideline recommendations, we defined target daily doses as ≥50 mg...... carvedilol and ≥200 mg metoprolol. Prior to implantation 2427 of 2935 (83%) patients received beta-blocker therapy, with 2166 patients (89%) having initiated treatment 3 months or more prior to implantation. The majority of patients was prescribed carvedilol (52%) or metoprolol (41%). Patients on carvedilol...

  12. Attitudes towards implantable cardioverter-defibrillator therapy: a national survey in Danish health-care professionals

    DEFF Research Database (Denmark)

    Johansen, Jens B; Mortensen, Peter T; Videbæk, Regitze

    2011-01-01

    Aims The aim of this study was to examine health-care professionals attitudes towards implantable cardioverter-defibrillator (ICD) therapy and issues discussed with patients. Methods and results Survey of 209 health-care professionals providing specialized treatment and care of ICD patients......-physicians. Physicians were less likely to believe that their personal attitude towards ICD treatment has no influence on how they deal professionally with patients (27.8 vs. 43.6%; P = 0.04). Physicians and non-physicians were equally positive towards ICD therapy as primary prophylaxis in ischaemic cardiomyopathy (87...... discussing ICD treatment with candidate patients. At the same time, physicians are more aware that their attitude towards ICD treatment may influence how they deal professionally with patients compared with non-physicians....

  13. "Real life" longevity of implantable cardioverter-defibrillator devices.

    Science.gov (United States)

    Manolis, Antonis S; Maounis, Themistoklis; Koulouris, Spyridon; Vassilikos, Vassilios

    2017-09-01

    Manufacturers of implantable cardioverter-defibrillators (ICDs) promise a 5- to 9-year projected longevity; however, real-life data indicate otherwise. The aim of the present study was to assess ICD longevity among 685 consecutive patients over the last 20 years. Real-life longevity of ICDs may differ from that stated by the manufacturers. The study included 601 men and 84 women (mean age, 63.1 ± 13.3 years). The underlying disease was coronary (n = 396) or valvular (n = 15) disease, cardiomyopathy (n = 220), or electrical disease (n = 54). The mean ejection fraction was 35%. Devices were implanted for secondary (n = 562) or primary (n = 123) prevention. Single- (n = 292) or dual-chamber (n = 269) or cardiac resynchronization therapy (CRT) devices (n = 124) were implanted in the abdomen (n = 17) or chest (n = 668). Over 20 years, ICD pulse generator replacements were performed in 238 patients (209 men; age 63.7 ± 13.9 years; ejection fraction, 37.7% ± 14.0%) who had an ICD for secondary (n = 210) or primary (n = 28) prevention. The mean ICD longevity was 58.3 ± 18.7 months. In 20 (8.4%) patients, devices exhibited premature battery depletion within 36 months. Most (94%) patients had none, minor, or modest use of ICD therapy. Longevity was longest for single-chamber devices and shortest for CRT devices. Latest-generation devices replaced over the second decade lasted longer compared with devices replaced during the first decade. When analyzed by manufacturer, Medtronic devices appeared to have longer longevity by 13 to 18 months. ICDs continue to have limited longevity of 4.9 ± 1.6 years, and 8% demonstrate premature battery depletion by 3 years. CRT devices have the shortest longevity (mean, 3.8 years) by 13 to 17 months, compared with other ICD devices. These findings have important implications, particularly in view of the high expense involved with this type of electrical

  14. Patient-reported outcomes in Danish implantable cardioverter defibrillator patients with a Sprint Fidelis lead advisory notification

    DEFF Research Database (Denmark)

    Pedersen, Susanne S; Versteeg, Henneke; Nielsen, Jens Cosedis

    2011-01-01

    Few studies have investigated the association between implantable cardioverter defibrillators (ICDs) and lead advisory notifications and patient-reported outcomes (PROs). We examined (i) whether the mode used to inform patients about a device advisory is associated with PROs, and (ii) whether...... patients with a lead subject to a device advisory report poorer PROs than non-advisory controls....

  15. Shock and patient preimplantation type D personality are associated with poor health status in patients with implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Tekle, Fetene B; Hoogwegt, Madelein T

    2012-01-01

    Implantable cardioverter-defibrillator (ICD) shock is a critical event to patients associated with well-being after implantation, although other factors may play an equally important role. We compared the association of shock and the patient's preimplantation personality with health status, using...

  16. Dual chamber arrhythmia detection in the implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2000-10-01

    Dual chamber implantable cardioverter defibrillator (ICD) technology extended ICD therapy to more than termination of hemodynamically unstable ventricular tachyarrhythmias. It created the basis for dual chamber arrhythmia management in which dependable detection is important for treatment and prevention of both ventricular and atrial arrhythmias. Dual chamber detection algorithms were investigated in two Medtronic dual chamber ICDs: the 7250 Jewel AF (33 patients) and the 7271 Gem DR (31 patients). Both ICDs use the same PR Logic algorithm to interpret tachycardia as ventricular tachycardia (VT), supraventricular tachycardia (SVT), or dual (VT+ SVT). The accuracy of dual chamber detection was studied in 310 of 1,367 spontaneously occurring tachycardias in which rate criterion only was not sufficient for arrhythmia diagnosis. In 78 episodes there was a double tachycardia, in 223 episodes SVT was detected in the VT or ventricular fibrillation zone, and in 9 episodes arrhythmia was detected outside the boundaries of the PR Logic functioning. In 100% of double tachycardias the VT was correctly diagnosed and received priority treatment. SVT was seen in 59 (19%) episodes diagnosed as VT. The causes of inappropriate detection were (1) algorithm failure (inability to fulfill the PR

  17. Electromagnetic Interference in Patients with Implanted Cardioverter-Defibrillators and Implantable Loop Recorders

    Directory of Open Access Journals (Sweden)

    Marcos de Sousa

    2002-07-01

    Full Text Available Modern life exposes us all to an ever-increasing number of potential sources of electromagnetic interference (EMI and patients with Implantable rhythm devices (IRD like pacemakers, implantable cardioverter defibrillators or implantable loop recorders often ask about the use of microwave ovens, walking through airport metal detectors and the use of cellular phones. Electromagnetic interference occurs when electromagnetic waves emitted by one device impede the normal function of another electronic device. The potential for interaction between implanted pacing systems and cardioverter-defibrillators (electromagnetic interference, EMI has been recognized for years.1,2,3,4. It has been shown that EMI can produce clinically significant effects on patients with implanted pacemakers and ICDs. For these reasons the following text discusses the influence of several EMI generating devices on IRD .

  18. Living with Your Implantable Cardioverter Defibrillator (ICD)

    Science.gov (United States)

    ... and Live Our Interactive Cardiovascular Library has detailed animations and illustrations to help you learn about conditions, treatments and procedures related to heart disease and stroke. Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  19. Magnetic resonance imaging at 1.5-T in patients with implantable cardioverter-defibrillators.

    Science.gov (United States)

    Naehle, Claas P; Strach, Katharina; Thomas, Daniel; Meyer, Carsten; Linhart, Markus; Bitaraf, Sascha; Litt, Harold; Schwab, Jörg Otto; Schild, Hans; Sommer, Torsten

    2009-08-04

    Our aim was to establish and evaluate a strategy for safe performance of magnetic resonance imaging (MRI) at 1.5-T in patients with implantable cardioverter-defibrillators (ICDs). Expanding indications for ICD placement and MRI becoming the imaging modality of choice for many indications has created a growing demand for MRI in ICD patients, which is still considered an absolute contraindication. Non-pacemaker-dependent ICD patients with a clinical need for MRI were included in the study. To minimize radiofrequency-related lead heating, the specific absorption rate was limited to 2 W/kg. ICDs were reprogrammed pre-MRI to avoid competitive pacing and potential pro-arrhythmia: 1) the lower rate limit was programmed as low as reasonably achievable; and 2) arrhythmia detection was programmed on, but therapy delivery was programmed off. Patients were monitored using electrocardiography and pulse oximetry. All ICDs were interrogated before and after the MRI examination and after 3 months, including measurement of pacing capture threshold, lead impedance, battery voltage, and serum troponin I. Eighteen ICD patients underwent a total of 18 MRI examinations at 1.5-T; all examinations were completed safely. All ICDs could be interrogated and reprogrammed normally post-MRI. No significant changes of pacing capture threshold, lead impedance, and serum troponin I were observed. Battery voltage decreased significantly from pre- to post-MRI. In 2 MRI examinations, oversensing of radiofrequency noise as ventricular fibrillation occurred. However, no attempt at therapy delivery was made. MRI of non-pacemaker-dependent ICD patients can be performed with an acceptable risk/benefit ratio under controlled conditions by taking both MRI- and pacemaker-related precautions. (Implantable Cardioverter Defibrillators and Magnetic Resonance Imaging of the Heart at 1.5-Tesla; NCT00356239).

  20. Pacemakers and implantable cardioverter defibrillators - general and anesthetic considerations

    Directory of Open Access Journals (Sweden)

    Amy G. Rapsang

    2014-06-01

    Full Text Available A pacemaking system consists of an impulse generator and lead or leads to carry the electrical impulse to the patient's heart. Pacemaker and implantable cardioverter defibrillator codes were made to describe the type of pacemaker or implantable cardioverter defibrillator implanted. Indications for pacing and implantable cardioverter defibrillator implantation were given by the American College of Cardiologists. Certain pacemakers have magnet-operated reed switches incorporated; however, magnet application can have serious adverse effects; hence, devices should be considered programmable unless known otherwise. When a device patient undergoes any procedure (with or without anesthesia, special precautions have to be observed including a focused history/physical examination, interrogation of pacemaker before and after the procedure, emergency drugs/temporary pacing and defibrillation, reprogramming of pacemaker and disabling certain pacemaker functions if required, monitoring of electrolyte and metabolic disturbance and avoiding certain drugs and equipments that can interfere with pacemaker function. If unanticipated device interactions are found, consider discontinuation of the procedure until the source of interference can be eliminated or managed and all corrective measures should be taken to ensure proper pacemaker function should be done. Post procedure, the cardiac rate and rhythm should be monitored continuously and emergency drugs and equipments should be kept ready and consultation with a cardiologist or a pacemaker-implantable cardioverter defibrillator service may be necessary.

  1. The Subcutaneous Implantable Cardioverter-Defibrillator: A Practical Review and Real-World Use and Application

    Directory of Open Access Journals (Sweden)

    Mark E. Panna Jr, MD, FACC, FHRS

    2016-02-01

    Full Text Available The subcutaneous implantable cardioverter-defibrillator (ICD is a novel technology using a subcutaneous (extrathoracic system for treatment of potential lethal ventricular arrhythmias. It avoids many of the risks of transvenous ICD implantation. It may be considered in patients having an ICD indication who do not have a pacing and/or cardiac resynchronization therapy indication, and who are unlikely to benefit from antitachycardia pacing therapy. We review patient selection, system components, the implantation technique, and screening considerations for subcutaneous ICD implantation. Its uses in specific patient populations, including children, patients with congenital heart disease, hypertrophic cardiomyopathy, or end-stage renal disease, and patients with preexisting pacemakers, are highlighted. Areas of future investigation are reviewed, including potential use with leadless pacing and magnetic resonance imaging.

  2. Trajectories of Patient-Reported Health Status in Patients With an Implantable Cardioverter Defibrillator

    DEFF Research Database (Denmark)

    Mastenbroek, Mirjam H; Denollet, Johan; Versteeg, Henneke

    2015-01-01

    , no use of ACE inhibitors, psychotropic medication, negative affectivity, and type D personality were identified as independent determinants of poorer mental health status. In conclusion, the population with an ICD seems to be heterogeneous in terms of patient-reported physical and mental health status......To date, no study has assessed the course of patient-reported health status in patients with an implantable cardioverter defibrillator (ICD). Studying health status trajectories and their baseline determinants would permit the identification of patients at risk for poor health outcomes after ICD...... implantation. A combined cohort of 1,222 patients with an ICD (79% men; age = 61.4 [11.2] years) completed the 12-Item Short-Form Health Survey at baseline and 2 to 3 months and 12 to 14 months after implantation. Latent class analyses were used to identify trajectories and predictors of health status over...

  3. Gender disparities in psychological distress and quality of life among patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Brouwers, Corline; van den Broek, Krista C; Denollet, Johan

    2011-01-01

    A subset of patients with an implantable cardioverter defibrillator (ICD) reports psychological distress and poor quality of life (QoL). Gender is one of the factors that has been proposed to explain individual differences in these outcomes. In this viewpoint, we (1) review the evidence for gender...... disparities in psychological distress and QoL in ICD patients by means of a systematic review, and (2) provide recommendations for future research and clinical implications. A systematic search of the literature identified 18 studies with a sample size ≥ 100 that examined gender disparities in anxiety....../depression and QoL in ICD patients (mean prevalence of women = 21%; mean age = 62 years). Our review shows that there is insufficient evidence to conclude that gender per se is a major autonomous predictor for disparities in psychological distress and QoL in ICD patients. Women had a higher prevalence of anxiety...

  4. Antitachycardia pacing programming in implantable cardioverter defibrillator: A systematic review.

    Science.gov (United States)

    De Maria, Elia; Giacopelli, Daniele; Borghi, Ambra; Modonesi, Letizia; Cappelli, Stefano

    2017-05-26

    Implantable cardioverter defibrillator (ICD) programming involves several parameters. In recent years antitachycardia pacing (ATP) has gained an increasing importance in the treatment of ventricular arrhythmias, whether slow or fast. It reduces the number of unnecessary and inappropriate shocks and improves both patient's quality of life and device longevity. There is no clear indication regarding the type of ATP to be used, except for the treatment of fast ventricular tachycardias (188 bpm-250 bpm) where it has been shown a greater efficacy and safety of burst compared to ramp; 8 impulses in each sequence of ATP appears to be the best programming option in this setting. Beyond ATP use, excellent clinical results were obtained with programming standardization following these principles: extended detection time in ventricular fibrillation (VF) zone; supraventricular discrimination criteria up to 200 bpm; first shock in VF zone at the maximum energy in order to reduce the risk of multiple shocks. The MADIT-RIT trial and some observational registries have also recently demonstrated that programming with a widespread use of ATP, higher cut-off rates or delayed intervention reduces the number of inappropriate and unnecessary therapies and improves the survival of patients during mid-term follow-up.

  5. Electroconvulsive therapy in patients with cardiac pacemakers and implantable cardioverter defibrillators.

    Science.gov (United States)

    Dolenc, Tamara J; Barnes, Roxann D; Hayes, David L; Rasmussen, Keith G

    2004-09-01

    Electroconvulsive therapy (ECT) is used to treat major depressive illness, especially in elderly and medically frail patients. Not uncommonly, these patients have cardiac pacemakers or implantable cardioverter defibrillators (ICDs). Only a few case reports in the literature describe the use of ECT in such patients. Herein we review our ECT experience treating 26 pacemaker patients and 3 ICD patients. All patients obtained significant antidepressant benefits with ETC. Only one serious cardiac event occurred, a case of supraventricular tachycardia (SVT) requiring a stay on the cardiac intensive care unit. The SVT resolved and the patient went on to receive further uncomplicated ECT treatments. We conclude from this experience that with proper pre-ECT cardiac and pacemaker/defibrillator assessment, ECT can be safely and effectively administered to patients with an implanted cardiac device.

  6. Daily remote monitoring of implantable cardioverter-defibrillators

    DEFF Research Database (Denmark)

    Hindricks, Gerhard; Varma, Niraj; Kacet, Salem

    2017-01-01

    Aims: Remote monitoring of implantable cardioverter-defibrillators may improve clinical outcome. A recent meta-analysis of three randomized controlled trials (TRUST, ECOST, IN-TIME) using a specific remote monitoring system with daily transmissions [Biotronik Home Monitoring (HM)] demonstrated...

  7. Venous Obstruction Following Pacemaker or Implantable Cardioverter-Defibrillator Implantation, Mini Review

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Akbarzadeh

    2016-08-01

    Full Text Available Venous obstruction is relatively frequent following permanent pacemaker or implantable cardioverter-defibrillator (ICD implantation. However, most of them are asymptomatic. Although the exact risk factor for this complication is not known, number of leads, heart failure and infection may prone the patient to this complication. The goal standard for detection of vein stenosis is venography; however, ultrasound sonography has an acceptable accuracy. Anticoagulant therapy may be considered for symptomatic patients. For device upgrading, non-functional leads removal, venoplasty and rarely surgical treatment may be indicated.

  8. Interactions between pacing and arrhythmia detection algorithms in the dual chamber implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2001-09-01

    Dual chamber implantable cardioverter defibrillator (ICD) combines the possibility to detect and treat ventricular and atrial arrhythmias with the possibility of modern heart stimulation techniques. Advanced pacing algorithms together with extended arrhythmia detection capabilities can give rise to new types of device-device interactions. Some of the possible interactions are illustrated by four cases documented in four models of dual chamber ICDs. Functioning of new features in dual chamber devices is influenced by the fact that the pacemaker is not a separate device but a part of the ICD system and that both are being used in a patient with arrhythmia. Programming measures are suggested to optimize use of new pacing algorithms while maintaining correct arrhythmia detection.

  9. Patients' perspective on deactivation of the implantable cardioverter-defibrillator near the end of life

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Chaitsing, Rismy; Szili-Torok, Tamas

    2013-01-01

    (67%) completed the survey. Most patients (68%) were aware that it is possible to turn the ICD off, and 95% believed it is important to inform patients about the possibility. Of the patients completing the survey, 84% indicated a choice for or against deactivation. Psychological morbidity......Recent guidelines have emphasized the importance of discussing the issue of deactivation near the end of life with patients with an implantable cardioverter-defibrillator (ICD). Few studies have examined the patient perspective and patients' wishes. We examined patients' knowledge and wishes...... for information; and the prevalence and correlates of a favorable attitude toward deactivation. Three cohorts of ICD patients (n = 440) extracted from our institutional database were asked to complete a survey that included a vignette about deactivation near the end of life. Of the 440 patients approached, 294...

  10. Impact of carvedilol and metoprolol on inappropriate implantable cardioverter-defibrillator therapy

    DEFF Research Database (Denmark)

    Ruwald, Martin H; Abu-Zeitone, Abeer; Jons, Christian

    2013-01-01

    The goal of this study was to evaluate the effects of carvedilol and metoprolol on the endpoint of inappropriate implantable cardioverter-defibrillator therapy in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation With Cardiac Resynchronization Therapy) study....

  11. Frequent Home Monitoring of ICD Is Effective to Prevent Inappropriate Defibrillator Shock Delivery

    Directory of Open Access Journals (Sweden)

    Paolo Bifulco

    2014-01-01

    Full Text Available Recently, in the context of telemedicine, telemonitoring services are gaining attention. They are offered, for example, to patients with implantable cardioverter defibrillators (ICDs. A major problem associated with ICD therapy is the occurrence of inappropriate shocks which impair patients’ quality of life and may also be arrhythmogenic. The telemonitoring can provide a valid support to intensify followup visits, in order to improve the prevention of inappropriate defibrillator shock, thus enhancing patient safety. Inappropriate shock generally depends on atrial fibrillation, supraventricular tachycardia, and abnormal sensing (such as those caused by electromagnetic interferences. As a practical example, an unusual case of an ICD patient who risked an inappropriate shock while taking a shower is reported. Continuous remote telemonitoring was able to timely warn cardiologist via GSM-SMS, who were able to detect improper sensing examining the intracardiac electrogram via Web. Patient was promptly contacted and warned to not further come in contact with the hydraulic system and any electrical appliance to prevent an inappropriate defibrillator shock. This demonstrates the effectiveness and usefulness of continuous remote telemonitoring in supporting ICD patients.

  12. Influence of radiotherapy on the latest generation of implantable cardioverter-defibrillators

    International Nuclear Information System (INIS)

    Hurkmans, Coen W.; Scheepers, Egon; Springorum, Bob G.F.; Uiterwaal, Hans

    2005-01-01

    Purpose: Radiotherapy can influence the functioning of pacemakers and implantable cardioverter-defibrillators (ICDs). ICDs offer the same functionality as pacemakers, but are also able to deliver a high-voltage shock to the heart if needed. Guidelines for radiotherapy treatment of patients with an implanted rhythm device have been published in 1994 by The American Association of Physicists in Medicine, and are based only on experience with pacemakers. Data on the influence of radiotherapy on ICDs are limited. The objective of our study is to determine the influence of radiotherapy on the latest generation of ICDs. Methods and Materials: Eleven modern ICDs have been irradiated in our department. The irradiation was performed with a 6-MV photon beam. The given dose was fractionated up to a cumulative dose of 120 Gy. Two to 5 days passed between consecutive irradiations. Frequency, output, sensing, telemetry, and shock energy were monitored. Results: Sensing interference by ionizing radiation on all ICDs has been demonstrated. For four ICDs, this would have caused the inappropriate delivery of a shock because of interference. At the end of the irradiation sessions, all devices had reached their point of failure. Complete loss of function was observed for four ICDs at dose levels between 0.5 Gy and 1.5 Gy. Conclusions: The effect of radiation therapy on the newest generation of ICDs varies widely. If tachycardia monitoring and therapy are functional (programmed on) during irradiation, the ICD might inappropriately give antitachycardia therapy, often resulting in a shock. Although most ICDs did not fail below 80 Gy, some devices had already failed at doses below 1.5 Gy. Guidelines are formulated for the treatment of patients with an ICD

  13. Cardioverter-defibrillator implantation in myeloma-associated cardiac amyloidosis.

    Science.gov (United States)

    Campanile, Alfonso; Sozzi, Fabiola B; Canetta, Ciro; Danzi, Gian Battista

    2013-01-01

    A 62-year-old woman with multiple myeloma and light-chain amyloidosis with significant heart involvement developed an in-hospital cardiac arrest. After cardiopulmonary resuscitation, a stable sinus rhythm without any cerebral damage was restored, and the patient was admitted to the coronary care unit. A cardioverter-defibrillator was implanted, and it successfully intervened in two sustained ventricular tachycardia episodes and one ventricular fibrillation episode, which were recorded during hospitalization. After achieving discrete cardiac compensation, the patient was transferred to the emergency medicine department where she underwent chemotherapy for multiple myeloma. The patient died 40 days after admission from refractory heart failure. In the literature, there are studies that describe the use of cardioverter-defibrillator implantation in cardiac amyloidosis; however, at present, there is no evidence of a beneficial effect on survival with the use of this intervention. A high index of suspicion for amyloid heart disease and early diagnosis are critical to improving outcomes.

  14. Beta-blocker therapy is not associated with symptoms of depression and anxiety in patients receiving an implantable cardioverter-defibrillator

    NARCIS (Netherlands)

    M.T. Hoogwegt (Madelein); N. Kupper (Nina); D.A.M.J. Theuns (Dominic); L.J.L.M. Jordaens (Luc); S.S. Pedersen (Susanne)

    2012-01-01

    textabstractBeta-blockers are frequently prescribed to implantable cardioverter-defibrillator (ICD) patients. Beta-blocker therapy has been proposed to induce emotional distress such as depression and anxiety, but a paucity of studies has examined the relationship between beta-blockers and distress.

  15. Comorbidity burden is associated with poor psychological well-being and physical health status in patients with an implantable cardioverter-defibrillator

    NARCIS (Netherlands)

    Hoogwegt, M.T.; Kupper, N.; Jordaens, L.; Pedersen, S.S.; Theuns, D.A.M.J.

    2013-01-01

    Aims Comorbidity burden has been linked to survival in patients with an implantable cardioverter-defibrillator (ICD), but no study has examined the influence on psychological well-being and health status. We examined the relationship between comorbidity burden and anxiety, depression, and health

  16. Comorbidity burden is associated with poor psychological well-being and physical health status in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Kupper, Nina; Jordaens, Luc

    2013-01-01

    Comorbidity burden has been linked to survival in patients with an implantable cardioverter-defibrillator (ICD), but no study has examined the influence on psychological well-being and health status. We examined the relationship between comorbidity burden and anxiety, depression, and health status...

  17. Current use of implantable electrical devices in Sweden: data from the Swedish pacemaker and implantable cardioverter-defibrillator registry.

    Science.gov (United States)

    Gadler, Fredrik; Valzania, Cinzia; Linde, Cecilia

    2015-01-01

    The National Swedish Pacemaker and Implantable Cardioverter-Defibrillator (ICD) Registry collects prospective data on all pacemaker and ICD implants in Sweden. We aimed to report the 2012 findings of the Registry concerning electrical devices implantation rates and changes over time, 1 year complications, long-term device longevity and patient survival. Forty-four Swedish implanting centres continuously contribute implantation of pacemakers and ICDs to the Registry by direct data entry on a specific website. Clinical and technical information on 2012 first implants and postoperative complications were analysed and compared with previous years. Patient survival data were obtained from the Swedish population register database. In 2012, the mean pacemaker and ICD first implantation rates were 697 and 136 per million inhabitants, respectively. The number of cardiac resynchronization therapy (CRT) first implantations/million capita was 41 (CRT pacemakers) and 55 (CRT defibrillators), with only a slight increase in CRT-ICD rate compared with 2011. Most device implantations were performed in men. Complication rates for pacemaker and ICD procedures were 5.3 and 10.1% at 1 year, respectively. Device and lead longevity differed among manufacturers. Pacemaker patients were older at the time of first implant and had generally worse survival rate than ICD patients (63 vs. 82% after 5 years). Pacemaker and ICD implantation rates seem to have reached a level phase in Sweden. Implantable cardioverter-defibrillator and CRT implantation rates are very low and do not reflect guideline indications. Gender differences in CRT and ICD implantations are pronounced. Device and patient survival rates are variable, and should be considered when deciding device type. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  18. Psychological and clinical problems in young adults with implantable cardioverter-defibrillators.

    Science.gov (United States)

    Wójcicka, Mariola; Lewandowski, Michał; Smolis-Bak, Edyta; Szwed, Hanna

    2008-10-01

    Implantable cardioverter-defibrillators (ICD) are the most effective treatment in patients with the risk of sudden cardiac death. ICD improves patients' safety but is also the source of numerous inconveniences. Especially young people consider such ICD-related inconveniences as most unwelcome. To assess the quality of life and main psychological problems encountered in young adults with an ICD. We studied 45 subjects aged 14-29 years (mean 21.2+/-4.3). ICDs were used in primary prevention in 22 patients, and in secondary prevention in 23 patients. Time elapsed from implantation ranged from 5 months to 11 years (4.3+/-2.7 years). Since the problems affecting this group were rather specific, the patients' quality of life was assessed with a special questionnaire addressing important issues and problems associated with living with an ICD. ICD discharges were observed in 67.4% of patients (primary prevention - 45.5%, secondary prevention - 82.6%), multiple shocks in 47.2%, and phantom shocks in 21.4%. Anxiety associated with an ICD discharge was reported by 84.4% of patients. In order to prevent ICD discharges, 53.3% of patients decreased their activity. Problems with memory were observed in 42.2% of patients, with concentration in 47.6%, and with sleep in 42.2%. Almost half of those over 18 years of age were active drivers. None of the subjects experienced an ICD discharge during sexual intercourse. None of the men reported any sexual problems, while seven (41.2%) women did. Almost a quarter of the patients claimed to have had complications after the implantation. Young adult patients generally were compliant to have their ICD checked and accepted their limitations and disease. Fewer people assessed their health status as bad. Some patients in the group studied found it extremely difficult to accept their disease and/or ICD and to adapt to the situation. As many as nine patients believed the ICD implantation had been unnecessary, seven did not accept the ICD, three

  19. Illness perceptions in patients with heart failure and an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Timmermans, I.; Versteeg, H.; Meine, Mathias M

    2017-01-01

    Background Patients' illness perceptions are associated with psychological wellbeing and can be measured with the Brief Illness Perception Questionnaire (B-IPQ). However, little is known about illness perceptions in patients with heart failure. We examined the dimensional structure, validity...... and clinical and psychological correlates of the B-IPQ in Dutch, French and German patients with heart failure and an implantable cardioverter defibrillator (ICD). Method European heart failure patients (n=585) participating in the REMOTE-CIED study completed a set of questionnaires 1–2weeks post ICD.......69, with the ‘Consequences’ subscale being more internally consistent (α=0.80). Both the B-IPQ and its ‘Consequences’ subscale were significantly correlated with a number of psychological characteristics, but not with clinical characteristics. Multivariable logistic regression analysis indicated that threatening illness...

  20. Relation between total shock energy and mortality in patients with implantable cardioverter-defibrillator.

    Science.gov (United States)

    Tenma, Taro; Yokoshiki, Hisashi; Mitsuyama, Hirofumi; Watanabe, Masaya; Mizukami, Kazuya; Kamada, Rui; Takahashi, Masayuki; Sasaki, Ryo; Maeno, Motoki; Okamoto, Kaori; Chiba, Yuki; Anzai, Toshihisa

    2018-05-15

    Implantable Cardioverter-Defibrillator (ICD) shocks have been associated with mortality. However, no study has examined the relation between total shock energy and mortality. The aim of this study is to assess the association of total shock energy with mortality, and to determine the patients who are at risk of this association. Data from 316 consecutive patients who underwent initial ICD implantation in our hospital between 2000 and 2011 were retrospectively studied. We collected shock energy for 3 years from the ICD implantation, and determined the relation of shock energy on mortality after adjusting confounding factors. Eighty-seven ICD recipients experienced shock(s) within 3 years from ICD implantation and 43 patients had died during the follow-up. The amount of shock energy was significantly associated with all-cause death [adjusted hazard ratio (HR) 1.26 (per 100 joule increase), p energy accumulation (≥182 joule) was lower (p energy accumulation (energy accumulation and all-cause death was remarkable in the patients with low left ventricular ejection fraction (LVEF ≤40%) or atrial fibrillation (AF). Increase of shock energy was related to mortality in ICD recipients. This relation was evident in patients with low LVEF or AF. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Electrical storm in patients with implantable cardioverter-defibrillators: can it be forecast?

    Science.gov (United States)

    Emkanjoo, Zahra; Alihasani, Narges; Alizadeh, Abolfath; Tayyebi, Mohammad; Bonakdar, Hamid; Barakpour, Hamid; Sadr-Ameli, Mohammad Ali

    2009-01-01

    The aim of this retrospective study was to determine the prevalence and predictors of electrical storm in 227 patients who had received implantable cardioverter-defibrillators (ICDs) and had been monitored for 31.7 +/- 15.6 months. Of these, 174 (77%) were men. The mean age was 55.8 +/- 15.5 years (range, 20-85 yr), and the mean left ventricular ejection fraction (LVEF) was 0.30 +/- 0.14. One hundred forty-six of the patients (64%) had underlying coronary artery disease. Cardioverter-defibrillators were implanted for secondary (80%) and primary (20%) prevention. Of the 227 patients, 117 (52%) experienced events that required ICD therapy. Thirty patients (mean age, 57.26 +/- 14.3 yr) had > or = 3 episodes requiring ICD therapy in a 24-hour period and were considered to have electrical storm. The mean number of events was 12.75 +/- 15 per patient. Arrhythmia-clustering occurred an average of 6.1 +/- 6.7 months after ICD implantation. Clinical variables with the most significant association with electrical storm were low LVEF (P = 0.04; hazard ratio of 0.261, and 95% confidence interval of 0.08-0.86) and higher use of class IA antiarrhythmic drugs (P = 0.018, hazard ratio of 3.84, and 95% confidence interval of 1.47-10.05). Amiodarone treatment and use of beta-blockers were not significant predictors when subjected to multivariate analysis. We conclude that electrical storm is most likely to occur in patients with lower LVEF and that the use of Class IA antiarrhythmic drugs is a risk factor.

  2. Implantable cardioverter-defibrillators improve survival after coronary artery bypass grafting in patients with severely impaired left ventricular function

    Directory of Open Access Journals (Sweden)

    Pasque Michael K

    2007-01-01

    Full Text Available Abstract Objective Patients with severe left ventricular (LV dysfunction have a poor long term survival despite complete surgical revascularization. Recent data suggests that the use of Implantable Cardioverter-Defibrillator (ICD improves survival in patients with severe LV dysfunction. We compared the survival impact of ICD implantation in patients with severe LV dysfunction who underwent CABG. Methods Between January 1996 and August 2004, 305 patients with LV ejection fraction (EF ≤25% had CABG surgery at our institution. Demographics of patients who had received an ICD (ICD+ in the post -operative period was compared to those without ICD (ICD-. Survival was evaluated by the Kaplan-Meier method. Results Of the entire group, 35 (11.5% patients received an ICD with a median of 2 (+/-2 years after CABG. Indication for ICD implantation was clinical evidence of non sustained ventricular tachycardia (NSVT. There were no differences between the 2 groups with respect to age, gender, NYHA classification, number of bypasses, or other co-morbidities. Survival at 1, 3 and 5 years was 88%, 79%, and 67% for the ICD- group compared to 94%, 89% and 83% for the ICD+ group, respectively (figure, p Conclusion Implantation of ICD after CABG confers improved short and long term survival benefit to patients with severe LV dysfunction. Prophylactic ICD implantation in the setting of severe LV dysfunction and CABG surgery should be considered.

  3. Beta-blocker therapy is not associated with symptoms of depression and anxiety in patients receiving an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Kupper, Nina; Theuns, Dominic A M J

    2012-01-01

    Beta-blockers are frequently prescribed to implantable cardioverter-defibrillator (ICD) patients. Beta-blocker therapy has been proposed to induce emotional distress such as depression and anxiety, but a paucity of studies has examined the relationship between beta-blockers and distress. We...... investigated the association between beta-blocker therapy, including type and dosage, and symptoms of anxiety and depression in a consecutive cohort of patients receiving an ICD....

  4. Complications and Mortality of Single Versus Dual Chamber Implantable Cardioverter Defibrillators

    Directory of Open Access Journals (Sweden)

    Ataallah Bagherzadeh

    2006-04-01

    Full Text Available Background: The implantable cardioverter defibrillators (ICDs are increasingly being used as a treatment modality for life threatening tachyarrhythmia. The purpose of this study was to compare the frequency of complications and mortality between single-chamber and dual-chamber ICD implantation in Shahid Rajaie cardiovascular center. Methods and results: Between January 2000 and December 2004, 234 patients received ICD by a percutaneous transvenous approach and were followed for 33 ± 23 months. The cumulative incidence of complications was 9.4% over the follow-up period. There was no significant difference in overall complication rate between single chamber (VR and dual chamber (DR ICD groups in the follow-up period (P= 0.11. The risk of complications did not have any statistically significant difference in secondary versus primary prevention groups (P=0.06. The complications were not associated with the severity of left ventricular systolic dysfunction (P=0.16.The frequency of lead-related complications was higher in dual chamber ICDs in comparison with single chamber ICDs (P=0.02. There was no significant difference in mortality between different sex groups (P=0.37, different indications for ICD implantation (P=0.43 or between VR and DR ICD groups (P= 0.55. Predictors of mortality were NYHA class III or more (P65 years (P=0.011 and LVEF<30% (P<0.001. The mortality in patients with CAD and DCM were significantly higher than those with other structural heart diseases (P=0.001. Conclusions: Close monitoring of patients during the first 2 month after ICD implantation is recommended because the majority of complications occur early after the procedure.

  5. Infrequent physician use of implantable cardioverter-defibrillators risks patient safety.

    Science.gov (United States)

    Lyman, Stephen; Sedrakyan, Art; Do, Huong; Razzano, Renee; Mushlin, Alvin I

    2011-10-01

    Implantable cardioverter-defibrillators (ICDs) have diffused rapidly into clinical practice with little evaluation of their real-world effectiveness. To determine the effect of the adoption of ICD on patient safety, particularly with respect to physician volume and early outcomes. Retrospective cohort of all ICD implantations in New York state from 1997 to 2006, with follow-up at 90 days and 1 year. Setting New York state non-federal hospital discharges in which an ICD was implanted during the admission. Patients were followed forward for 1 year for subsequent admissions. Patients New York state residents undergoing ICD implantation. Effects of annual and career ICD implantation volume on 90-day complication, readmission, reprogramming, mortality and revision of the ICD within 1 year. This cohort (N = 38,992) represents a period of rapid adoption and implementation of this new technology, with frequency more than tripling between 1997 and 2006. We identified 6439 (16.5%) post-implantation complications and 1093 (2.8%) deaths within 90 days of implantation. The majority (73.4%) of physicians implanted one or fewer ICDs per year, and 11.0% of all implantations were performed by these very-low-volume operators. Patients treated by very-low-volume operators were more likely to die (RR = 1.8, 95% CI 1.3 to 2.4) or experience cardiac complications (RR = 4.7, 95% CI 3.3 to 6.8) even after the adjustment for case mix compared to operators who frequently performed ICD implantation. These findings suggest a need for safe and effective implementation strategies for new medical technologies, which minimize patient risk due to rapid diffusion among inexperienced providers and assure that the intended benefit can be maximised rapidly.

  6. Time dependence of risks and benefits in pediatric primary prevention implantable cardioverter-defibrillator therapy.

    Science.gov (United States)

    DeWitt, Elizabeth S; Triedman, John K; Cecchin, Frank; Mah, Doug Y; Abrams, Dominic J; Walsh, Edward P; Gauvreau, Kimberlee; Alexander, Mark E

    2014-12-01

    Implantable cardioverter defibrillators (ICDs) used to prevent sudden cardiac arrest in children not only provide appropriate therapy in 25% of patients but also result in a significant incidence of inappropriate shocks and other device complications. ICDs placed for secondary prevention have higher rates of appropriate therapy than those placed for primary prevention. Pediatric patients with primary prevention ICDs were studied to determine time-dependent incidence of appropriate use and adverse events. A total of 140 patients aged prevention were retrospectively identified. Demographics and times to first appropriate shock; adverse events (including inappropriate shock, lead failure, reintervention, and complication); generator replacement and follow-up were noted. During mean follow-up of 4 years, appropriate shock occurred in 19% patients and first adverse event (excluding death/transplant) occurred in 36%. Risk of death or transplant was ≈1% per year and was not related to receiving appropriate therapy. Conditional survival analysis showed rates of appropriate therapy and adverse events decrease soon after implantation, but adverse events are more frequent than appropriate therapy throughout follow-up. Primary prevention ICDs were associated with appropriate therapy in 19% and adverse event in 36% in this cohort. The incidence of both first appropriate therapy and device-related adverse events decreased during longer periods of follow-up after implantation. This suggests that indications for continued device therapy in pediatric primary prevention ICD patients might be reconsidered after a period of nonuse. © 2014 American Heart Association, Inc.

  7. Evidence of Cognitive Bias in Decision Making Around Implantable-Cardioverter Defibrillators: A Qualitative Framework Analysis.

    Science.gov (United States)

    Matlock, Daniel D; Jones, Jacqueline; Nowels, Carolyn T; Jenkins, Amy; Allen, Larry A; Kutner, Jean S

    2017-11-01

    Studies have demonstrated that patients with primary prevention implantable cardioverter-defibrillators (ICDs) often misunderstand the ICD. Advances in behavioral economics demonstrate that some misunderstandings may be due to cognitive biases. We aimed to explore the influence of cognitive bias on ICD decision making. We used a qualitative framework analysis including 9 cognitive biases: affect heuristic, affective forecasting, anchoring, availability, default effects, halo effects, optimism bias, framing effects, and state dependence. We interviewed 48 patients from 4 settings in Denver. The majority were male (n = 32). Overall median age was 61 years. We found frequent evidence for framing, default, and halo effects; some evidence of optimism bias, affect heuristic, state dependence, anchoring and availability bias; and little or no evidence of affective forecasting. Framing effects were apparent in overestimation of benefits and downplaying or omitting potential harms. We found evidence of cognitive bias in decision making for ICD implantation. The majority of these biases appeared to encourage ICD treatment. Published by Elsevier Inc.

  8. Congenital short QT syndrome and implantable cardioverter defibrillator treatment: inherent risk for inappropriate shock delivery.

    Science.gov (United States)

    Schimpf, Rainer; Wolpert, Christian; Bianchi, Francesca; Giustetto, Carla; Gaita, Florenzo; Bauersfeld, Urs; Borggrefe, Martin

    2003-12-01

    A congenital short QT interval constitutes a new primary electrical abnormality associated with syncope and/or sudden cardiac death. We report on the initial use of implantable cardioverter defibrillator (ICD) therapy in patients with inherited short QT interval and discuss sensing abnormalities and detection issues. In five consecutive patients from two unrelated European families who had structurally normal hearts, excessively shortened QT intervals, and a strong positive family history of sudden cardiac death, ICDs were placed for primary and secondary prevention. Mean QT intervals were 252 +/- 13 ms (QTc 287 +/- 13 ms). Despite normal sensing behavior during intraoperative and postoperative device testing, 3 of 5 patients experienced inappropriate shock therapies for T wave oversensing 30 +/- 26 days after implantation. Programming lower sensitivities and decay delays prevented further inappropriate discharges. The congenital short QT syndrome constitutes a new clinical entity with an increased risk for sudden cardiac death. Currently, ICD treatment is the only therapeutic option. In patients with short QT interval and implanted ICD, increased risk for inappropriate therapy is inherent due to the detection of short-coupled and prominent T waves. Careful testing of ICD function and adaptation of sensing levels and decay delays without sacrificing correct arrhythmia detection are essential.

  9. Cardiac e-learning: Development of a web-based implantable cardioverter defibrillator educational system.

    Science.gov (United States)

    Hickey, Kathleen T; Johnson, Mary P; Biviano, Angelo; Aboelela, Sally; Thomas, Tami; Bakken, Suzanne; Garan, Hasan; Zimmerman, John L; Whang, William

    2011-04-01

    The objective of this study was to design a Web-based implantable cardioverter defibrillator (ICD) module that would allow greater access to learning which could occur at an individual's convenience outside the fast-paced clinical environment. A Web-based ICD software educational program was developed to provide general knowledge of the function of the ICD and the interpretation of the stored electrocardiograms. This learning tool could be accessed at any time via the Columbia University Internet server, using a unique, password protected login. A series of basic and advanced ICD terms were presented using actual ICD screenshots and videos that simulated scenarios the practitioner would most commonly encounter in the fast-paced clinical setting. To determine the usefulness of the site and improve the module, practitioners were asked to complete a brief (less than 5 min) online survey at the end of the module. Twenty-six practitioners have logged into our Web site: 20 nurses/nurse practitioners, four cardiac fellows, and two other practitioners. The majority of respondents rated the program as easy to use and useful. The success of this module has led to it becoming part of the training for student nurse practitioners before a clinical electrophysiology rotation, and the module is accessed by our cardiac entry level fellows before a rotation in the intensive care unit or electrophysiology service. Remote electronic arrhythmia learning is a successful example of the melding of technology and education to enhance clinical learning.

  10. Comparison of clinical benefits and outcome in patients with programmable and nonprogrammable implantable cardioverter defibrillators.

    Science.gov (United States)

    Mehta, D; Saksena, S; Krol, R B; Makhija, V

    1992-09-01

    Technological advances in implantable cardioverter defibrillators (ICDs) have provided a variety of programmable parameters and antitachycardia therapies whose utility and impact on clinical outcome is presently unknown. ICDs have capabilities for cardioversion defibrillation alone (first generation ICDs), or in conjunction with demand ventricular pacing (second generation ICDs), or with demand pacing and antitachycardia pacing (third generation ICDs). We examined the pattern of antitachycardia therapy use and long-term survival in 110 patients with sustained ventricular tachycardia (VT) or ventricular fibrillation (VF). Group I included 62 patients with nonprogrammable first generation ICDs that delivered committed shock therapy after ventricular tachyarrhythmia detection based on electrogram rate and/or morphology was satisfied. Group II included 48 patients with multiprogrammable ICDs (including second and third generation ICDs) that had programmable tachyarrhythmia detection based on rate and tachycardia confirmation prior to delivery of electrical treatment with either programmable shocks and/or, as in the third generation ICDs, antitachycardia pacing. Incidence and patterns of antitachycardia therapy use and long-term survival were compared in the two groups. The incidence of appropriate shocks in patients who completed 1 year of follow-up was significantly greater in group I (30 of 43 patients = 70% vs 11 of 26 patients = 42%; P less than 0.05). In the total follow-up period, a significantly larger proportion of group I patients as compared to group II patients used the shock therapies (46 of 62 patients = 74% vs 25 of 48 patients = 52%; P less than 0.01), with the majority doing so within the first year of implantation (96% and 92%, respectively). Although the frequency of antitachycardia therapy activation was similar, the number of shocks delivered per patient was lower in group II, particularly in the initial 3 months of follow-up (P = 0.06). No clinical

  11. The effect of intermittent atrial tachyarrhythmia on heart failure or death in cardiac resynchronization therapy with defibrillator versus implantable cardioverter-defibrillator patients

    DEFF Research Database (Denmark)

    Ruwald, Anne-Christine; Pietrasik, Grzegorz; Goldenberg, Ilan

    2014-01-01

    OBJECTIVES: This study aimed to investigate the effect of both history of intermittent atrial tachyarrhythmias (IAT) and in-trial IAT on the risk of heart failure (HF) or death comparing cardiac resynchronization therapy with defibrillator (CRT-D) to implantable cardioverter-defibrillator (ICD......) treatment in mildly symptomatic HF patients with left bundle branch block (LBBB). BACKGROUND: Limited data exist regarding the benefit of CRT-D in patients with IAT. METHODS: The benefit of CRT-D in reducing the risk of HF/death was evaluated using multivariate Cox models incorporating the presence of......-D versus ICD on the risk of HF/death was not significantly different between LBBB patients with or without history of IAT (HR: 0.50, p = 0.028, and HR: 0.46, p

  12. Implantable cardioverter-defibrillator explantation for overdiagnosed or overtreated congenital long QT syndrome.

    Science.gov (United States)

    Gaba, Prakriti; Bos, J Martijn; Cannon, Bryan C; Cha, Yong-Mei; Friedman, Paul A; Asirvatham, Samuel J; Ackerman, Michael J

    2016-04-01

    Primary treatment of long QT syndrome (LQTS) currently consists of beta-blocker therapy, although an implantable cardioverter-defibrillator (ICD) is considered for high-risk patients. However, both overdiagnosis and overtreatment must be avoided because their sequelae can be significant. The purpose of this study was to evaluate the prevalence and details of ICD explants in a cohort of patients from a tertiary genetic heart rhythm clinic for a previously rendered diagnosis of LQTS. Overall, 1227 consecutive patients were included in the study. All patients had been referred to the Mayo Clinic for evaluation of possible LQTS and subsequently were either diagnosed with LQTS or dismissed as normal. Further stratification of patients was conducted to assess how many patients had an ICD and how many had a subsequent ICD explant. In total, 170 patients (14%) had an ICD, including 157 of 670 patients (23%) with confirmed LQTS and 13 of 557 patients (2%) who did not have LQTS. Among these, 12 of 1227 (1%) had the ICD removed: 7 of 157 LQTS patients (4.5%) compared to 5 of 14 non-LQTS patients (36%). Before explant, 5 of 12 patients (42%) experienced inappropriate shocks, ranging from 2 to as many as 54 shocks. In addition, 4 had a device-related infection, and 9 had device malfunction (including lead dysfunction or fracture). None of these patients had a breakthrough cardiac event since removal of their ICD during 5.5 ± 3.5 years of follow-up. Implications of overdiagnosis and overtreatment are profound because unnecessary ICD placement can be associated with infection, malfunction, inappropriate shocks, and subsequent anxiety. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  13. Management of Implantable Cardioverter Defibrillator Recipients: Care Beyond Guidelines.

    Science.gov (United States)

    Philippon, François; Sterns, Laurence D; Nery, Pablo B; Parkash, Ratika; Birnie, David; Rinne, Claus; Mondesert, Blandine; Exner, Derek; Bennett, Matthew

    2017-08-01

    This companion article is intended to address common clinical scenarios in patients with implantable defibrillators that were not addressed in the 2016 Canadian Cardiovascular Society/Canadian Heart Rhythm Society implantable cardioverter defibrillator guidelines including recommendations for device programming to improve detection, to minimize shocks (appropriate and inappropriate), and to minimize ventricular pacing. Important issues at the time of replacement such as device prescription, technical aspects (vascular access, extraction), and management of components on advisories are also discussed. Finally, common clinical scenarios such as management of patients with terminal illnesses, recurrent ventricular tachycardia, electrical storms, catheter ablation for ventricular tachycardia, and system infection management are considered. The management of these patients requires a team approach and comprehensive knowledge surrounding these common clinical scenarios. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  14. In vitro assessment of the immunity of implantable cardioverter-defibrillators to magnetic fields of 50/60 Hz

    International Nuclear Information System (INIS)

    Katrib, J; Nadi, M; Kourtiche, D; Schmitt, P; Roth, P; Magne, I; Souques, M

    2013-01-01

    Public concern for the compatibility of electromagnetic (EM) sources with active implantable medical devices (AIMD) has prompted the development of new systems that can perform accurate exposure studies. EM field interference with active cardiac implants (e.g. implantable cardioverter-defibrillators (ICDs)) can be critical. This paper describes a magnetic field (MF) exposure system and the method developed for testing the immunity of ICD to continuous-wave MFs. The MFs were created by Helmholtz coils, housed in a Faraday cage. The coils were able to produce highly uniform MFs up to 4000 µT at 50 Hz and 3900 µT at 60 Hz, within the test space. Four ICDs were tested. No dysfunctions were found in the generated MFs. These results confirm that the tested ICDs were immune to low frequency MFs. (paper)

  15. Standardized programming to reduce the burden of inappropriate therapies in implantable cardioverter defibrillators - Single centre follow up results

    Directory of Open Access Journals (Sweden)

    U. Boles

    2018-03-01

    Full Text Available Background: Current algorithms and device morphology templates have been proposed in current Implantable Cardioverter-Defibrillators (ICDs to minimize inappropriate therapies (ITS, but this has not been completely successful. Aim: Assess the impact of a deliberate strategy of using an atrial lead implant with standardized parameters; based on all current ICD discriminators and technologies, on the burden of ITS. Method: A retrospective single-centre analysis of 250 patients with either dual chamber (DR ICDs or biventricular ICDs (CRTDs over a (41.9 ± 27.3 month period was performed. The incidence of ITS on all ICD and CRTD patients was chronicled after the implementation of standardized programming. Results: 39 events of anti-tachycardial pacing (ATP and/or shocks were identified in 20 patients (8% incidence rate among patients. The total number of individual therapies was 120, of which 34% were inappropriate ATP, and 36% were inappropriate shocks. 11 patients of the 250 patients received ITS (4.4%. Of the 20 patients, four had ICDs for primary prevention and 16 for a secondary prevention. All the episodes in the primary indication group were inappropriate, while seven patients (43% of the secondary indication group experienced inappropriate therapies. Conclusions: The burden of ITS in the population of patients receiving ICDs was 4.4% in the presence of atrial leads. The proposed rationalized programming criteria seems an effective strategy to minimize the burden of inappropriate therapies and will require further validation. Keywords: Implantable cardioverter-defibrillator (ICDs, Inappropriate therapies, Standardized programming

  16. Potential interference of small neodymium magnets with cardiac pacemakers and implantable cardioverter-defibrillators.

    Science.gov (United States)

    Wolber, Thomas; Ryf, Salome; Binggeli, Christian; Holzmeister, Johannes; Brunckhorst, Corinna; Luechinger, Roger; Duru, Firat

    2007-01-01

    Magnetic fields may interfere with the function of cardiac pacemakers and implantable cardioverter-defibrillators (ICDs). Neodymium-iron-boron (NdFeB) magnets, which are small in size but produce strong magnetic fields, have become widely available in recent years. Therefore, NdFeB magnets may be associated with an emerging risk of device interference. We conducted a clinical study to evaluate the potential of small NdFeB magnets to interfere with cardiac pacemakers and ICDs. The effect of four NdFeB magnets (two spherical magnets 8 and 10 mm in diameter, a necklace made of 45 spherical magnets, and a magnetic name tag) was tested in forty-one ambulatory patients with a pacemaker and 29 patients with an ICD. The maximum distance at which the magnetic switch of a device was influenced was observed. Magnetic interference was observed in all patients. The maximum distance resulting in device interference was 3 cm. No significant differences were found with respect to device manufacturer and device types. Small NdFeB magnets may cause interference with cardiac pacemakers and ICDs. Patients should be cautioned about the interference risk associated with NdFeB magnets during daily life.

  17. Low risk of electromagnetic interference between smartphones and contemporary implantable cardioverter defibrillators.

    Science.gov (United States)

    Burri, Haran; Mondouagne Engkolo, Louis Paulin; Dayal, Nicolas; Etemadi, Abdul; Makhlouf, Anne-Marie; Stettler, Carine; Trentaz, Florence

    2016-05-01

    Manufacturers of implantable cardioverter defibrillators (ICDs) recommend that cell phones be maintained at a distance of ∼15 cm from the implanted device in order to avoid risk of dysfunction due to electromagnetic interference (EMI). Data relating to this issue are outdated and do not reflect modern technology. Our aim was to evaluate whether EMI is still an issue with contemporary ICDs and smartphones. Consecutive patients implanted with a wireless-enabled ICD were tested for potential interference with two models of recent 4G smartphones in conditions intended to maximize risk of EMI. A magnet effect (due to the phone speakers) was tested by placing the smartphones in the standby mode directly over the ICD generator. The presence of EMI artefacts on the real-time electrograms was evaluated by placing the smartphones in the standby, dialling, and operating modes directly over the generator casing and over the parasternal region in the vicinity of the ventricular lead. A total of 63 patients equipped with 29 different models of single, dual, or biventricular ICDs from five major manufacturers were included. None of the patients showed any evidence of interference with the smartphones during any of the 882 tests. The risk of EMI between modern smartphones and contemporary ICDs is low. This is probably due to the filters incorporated in the ICDs and low emission by the phones, as well as the small size of the magnets in the smartphones tested. NCT02330900 (http://www.clinicaltrials.gov). Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  18. Relation of statin therapy to psychological functioning in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Theuns, Dominic A M J; Kupper, Nina

    2013-01-01

    Statin therapy is an important secondary prevention measure in cardiovascular disease. However, the side effects associated with statin use could potentially affect patients' quality of life. Little is known about the influence of statin therapy on the well-being and health status of cardiac...... patients, in general, and patients with an implantable cardioverter defibrillator (ICD), in particular. We investigated the association between statin therapy and symptoms of anxiety and depression and patients' health status during the 12 months after implantation, reckoning with statin type and dosage...... of statin type, dosage, and other potential confounders. The associations between statin therapy and depression (p = 0.06) and statin therapy and physical functioning (p = 0.05) were borderline significant, and no association was found with anxiety (p >0.05). In conclusion, statin therapy was associated...

  19. Relation between emotional distress and heart rate variability in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Pedersen, Susanne S.; Theuns, Dominic A M J

    2014-01-01

    We investigated the relationship between Type D personality, depression, and anxiety, and heart rate variability (HRV) in 64 patients with an implantable cardioverter-defibrillator (ICD). HRV was obtained via 24-h Holter monitoring, and 24-h, 30-min daytime rest and 30-min nighttime sleep HRV were...... analyzed. In adjusted analyses, significant associations (standard deviation of normal-to-normal [NN] intervals [SDNN]: p = .043; standard deviation of NN intervals over 5-min periods [SDANN]: p = .010) and a trend (HRV triangular index: p = .09) were found for Type D personality, and trends were found...... = .043). A Benjamini-Hochberg correction for multiple testing led to reduction of the number of significant relationships, but there was still support for lower autonomic control patients with Type D personality and depression. Future research with larger sample sizes is warranted....

  20. Outcomes with single-coil versus dual-coil implantable cardioverter defibrillators: a meta-analysis.

    Science.gov (United States)

    Sunderland, Nicholas; Kaura, Amit; Murgatroyd, Francis; Dhillon, Para; Scott, Paul A

    2018-03-01

    Dual-coil implantable cardioverter defibrillator (ICD) leads have traditionally been used over single-coil leads due to concerns regarding high defibrillation thresholds (DFT) and consequent poor shock efficacy. However, accumulating evidence suggests that this position may be unfounded and that dual-coil leads may also be associated with higher complication rates during lead extraction. This meta-analysis collates data comparing dual- and single-coil ICD leads. Electronic databases were systematically searched for randomized controlled trials (RCT) and non-randomized studies comparing single-coil and dual-coil leads. The mean differences in DFT and summary estimates of the odds-ratio (OR) for first-shock efficacy and the hazard-ratio (HR) for all-cause mortality were calculated using random effects models. Eighteen studies including a total of 138,124 patients were identified. Dual-coil leads were associated with a lower DFT compared to single coil leads (mean difference -0.83J; 95% confidence interval [CI] -1.39--0.27; P = 0.004). There was no difference in the first-shock success rate with dual-coil compared to single-coil leads (OR 0.74; 95%CI 0.45-1.21; P=0.22). There was a significantly lower risk of all-cause mortality associated with single-coil leads (HR 0.91; 95%CI 0.86-0.95; P dual-coil leads. The mortality benefit with single-coil leads most likely represents patient selection bias. Given the increased risk and complexity of extracting dual-coil leads, centres should strongly consider single-coil ICD leads as the lead of choice for routine new left-sided ICD implants. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  1. Correlation of geomagnetic activity with implantable cardioverter defibrillator shocks and antitachycardia pacing

    Czech Academy of Sciences Publication Activity Database

    Ebrille, E.; Konecny, T.; Konecny, D.; Špaček, R.; Jones, P.; Ambrož, Pavel; DeSimone, C.V.; Powel, B.D.; Hayes, D.L.; Friedman, P.A.; Asirvatham, S.J.

    2015-01-01

    Roč. 90, č. 2 (2015), s. 202-208 ISSN 0025-6196 Institutional support: RVO:67985815 Keywords : geomagnetic activity * implantable cardioverter defibrillator Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery Impact factor: 5.920, year: 2015

  2. Digoxin Is Associated With Increased Shock Events and Electrical Storms in Patients With Implantable Cardioverter Defibrillators.

    Science.gov (United States)

    Mina, George S; Acharya, Madan; Shepherd, Taylor; Gobrial, George; Tekeste, Michael; Watti, Hussam; Bhandari, Ruchi; Saini, Aditya; Reddy, Pratap; Dominic, Paari

    2018-03-01

    Recently, digoxin use has been found to associate with higher mortality. Yet, potential mechanisms by which digoxin use increases mortality remain unclear. Increased arrhythmogenicity from digoxin use is one possibility. Thus, we aimed to evaluate the relation between digoxin and shock events in patients with implantable cardioverter defibrillators (ICDs). We performed a retrospective chart review of all patients with ICDs and at least 1 device interrogation at our institution between January 1, 2012, and January 1, 2015. We aimed to cover 1 year of interrogation period. Patients with heart failure, atrial fibrillation, or both were included in the analysis. Patients were divided into 2 groups based on digoxin use, defined as use of digoxin for any period of time during ICD interrogation period. Incidence of ICD shock events and electrical storms and hospitalizations were compared between the 2 groups. The study included 202 patients. Of those, 55 patients were on digoxin and 147 were not on digoxin. Patients on digoxin were more likely to receive ICD shocks (odds ratio [OR] = 2.5, 95% confidence interval [95% CI] = 1.01-6.18, P = .04) and have increased risk of electrical storms ( P = .02). Moreover, total hospitalizations were higher in digoxin users ( P = .02). Multivariate logistic regression analysis also showed that digoxin use was an independent predictor of shock events (OR = 4.07, 95% CI = 1.43-11.58, P = .009). Digoxin is associated with increased shock events and electrical storms in patients with ICDs; however, large randomized controlled studies are needed to confirm our findings.

  3. Feedback to providers improves evidence-based implantable cardioverter-defibrillator programming and reduces shocks.

    Science.gov (United States)

    Silver, Marc T; Sterns, Laurence D; Piccini, Jonathan P; Joung, Boyoung; Ching, Chi-Keong; Pickett, Robert A; Rabinovich, Rafael; Liu, Shufeng; Peterson, Brett J; Lexcen, Daniel R

    2015-03-01

    Implantable cardioverter-defibrillator (ICD) shocks are associated with increased anxiety, health care utilization, and potentially mortality. The purpose of the Shock-Less Study was to determine if providing feedback reports to physicians on their adherence to evidence-based shock reduction programming could improve their programming behavior and reduce shocks. Shock-Less enrolled primary prevention (PP) and secondary prevention (SP) ICD patients between 2009 and 2012 at 118 study centers worldwide and followed patients longitudinally after their ICD implant. Center-specific therapy programming reports (TPRs) were delivered to each center 9 to 12 months after their first enrollment. The reports detailed adherence to evidence-based programming targets: number of intervals to detect ventricular fibrillation (VF NID), longest treatment interval (LTI), supraventricular tachycardia (SVT) discriminators (Wavelet, PR Logic), SVT limit, Lead Integrity Alert (LIA), and antitachycardia pacing (ATP). Clinicians programmed ICDs at their discretion. The primary outcome measure was the change in utilization of evidence-based shock reduction programming before (phase I, n = 2694 patients) and after initiation of the TPR (phase II, n = 1438 patients). Patients implanted after feedback reports (phase II) were up to 20% more likely to have their ICDs programmed in line with evidence-based shock reduction programming (eg, VF NID in PP patients 30/40 in 33.5% vs 18.6%, P programming feedback reports improves adherence to evidence-based shock reduction programming and is associated with lower risk of ICD shocks. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  4. Risk of pacemaker or implantable cardioverter defibrillator after radiotherapy for early-stage breast cancer in Denmark, 1982-2005

    DEFF Research Database (Denmark)

    Rehammar, Jens Christian; Johansen, Jens Brock; Jensen, Maj-Britt

    2017-01-01

    BACKGROUND AND PURPOSE: To examine the risk of cardiac conduction abnormalities or severe ventricular arrhythmias requiring implantation of a cardiac implantable electronic device (CIED), either a pacemaker or an implantable cardioverter-defibrillator, subsequent to breast cancer (BC) radiotherapy...... (RT). MATERIAL AND METHODS: All women treated for early-stage BC in Denmark from 1982 to 2005 were identified from the Danish Breast Cancer Cooperative Group. By record linkage to the Danish Pacemaker and ICD Registry information was retrieved on CIED implants subsequent to RT. Standardized incidence...

  5. Implantable Cardioverter-Defibrillator Therapy in Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy: Predictors of Appropriate Therapy, Outcomes, and Complications.

    Science.gov (United States)

    Orgeron, Gabriela M; James, Cynthia A; Te Riele, Anneline; Tichnell, Crystal; Murray, Brittney; Bhonsale, Aditya; Kamel, Ihab R; Zimmerman, Stephan L; Judge, Daniel P; Crosson, Jane; Tandri, Harikrishna; Calkins, Hugh

    2017-06-06

    Arrhythmogenic right ventricular dysplasia/cardiomyopathy is characterized by ventricular arrhythmias and sudden cardiac death. Once the diagnosis is established, risk stratification to determine whether implantable cardioverter-defibrillator (ICD) placement is warranted is critical. The cohort included 312 patients (163 men, age at presentation 33.6±13.9 years) with definite arrhythmogenic right ventricular dysplasia/cardiomyopathy who received an ICD. Over 8.8±7.33 years, 186 participants (60%) had appropriate ICD therapy and 58 (19%) had an intervention for ventricular fibrillation/flutter. Ventricular tachycardia at presentation (hazard ratio [HR]: 1.86; 95% confidence interval [CI], 1.38-2.49; P right ventricular dysplasia/cardiomyopathy. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  6. Optimism as predictor of patient-reported outcomes in patients with an implantable cardioverter defibrillator (data from the WEBCARE study)

    DEFF Research Database (Denmark)

    Habibović, M; Broers, E; Heumen, D

    2018-01-01

    OBJECTIVE: The implantable cardioverter defibrillator (ICD) is the treatment of choice for prevention of sudden cardiac death. However, a subgroup of ICD patients experiences psychological adjustment problems post implant. To date, positive psychological constructs (e.g. optimism) have been...... understudied in this population. Hence, we examined the association between optimism and anxiety, depression, and health status at 12-months post implant. METHODS: Patients (N=171) enrolled in the WEB-based distress management study for ICD patients were included in the analyses. Optimism and pessimism (LOT......), and Type D personality (DS14) were administered at baseline, while anxiety (GAD-7), depression (PHQ-9), and health status (SF-12) were assessed at 12-months. RESULTS: The mean age was 59.6±10.06 with 81% being male. After controlling for demographic, personality, and clinical variables, baseline optimism...

  7. Depression, psychological distress, and quality of life in patients with cardioverter defibrillator with or without cardiac resynchronization therapy.

    Science.gov (United States)

    Knackstedt, Christian; Arndt, Marlies; Mischke, Karl; Marx, Nikolaus; Nieman, Fred; Kunert, Hanns Jürgen; Schauerte, Patrick; Norra, Christine

    2014-05-01

    Congestive heart failure is frequent and leads to reduced exercise capacity, reduced quality of life (QoL), and depression in many patients. Cardiac resynchronization therapy (CRT) and implantable cardioverter defibrillators (ICD) offer therapeutic options and may have an impact on QoL and depression. This study was performed to evaluate physical and mental health in patients undergoing ICD or combined CRT/ICD-implantation (CRT-D). Echocardiography, spiroergometry, and psychometric questionnaires [Beck Depression Inventory, General World Health Organization Five Well-being Index (WHO-5), Brief Symptom Inventory and 36-item Short Form (SF-36)] were obtained in 39 patients (ICD: 17, CRT-D: 22) at baseline and 6-month follow-up (FU) after device implantation. CRT-D patients had a higher NYHA class and broader left bundle branch block than ICD patients at baseline. At FU, ejection fraction (EF), peak oxygen uptake, and NYHA class improved significantly in CRT-D patients but remained unchanged in ICD patients. Patients with CRT-D implantation showed higher levels of depressive symptoms, psychological distress, and impairment in QoL at baseline and FU compared to ICD patients. These impairments remained mostly unchanged in all patients after 6 months. Overall, these findings imply that there is a need for careful assessment and treatment of psychological distress and depression in ICD and CRT-D patients in the course of device implantation as psychological burden seems to persist irrespective of physical improvement.

  8. [Guidelines on the management of implantable cardioverter defibrillators at the end of life].

    Science.gov (United States)

    Datino, T; Rexach, L; Vidán, M T; Alonso, A; Gándara, Á; Ruiz-García, J; Fontecha, B; Martínez-Sellés, M

    2014-01-01

    This article is a joint document of the Spanish Society of Geriatrics and Gerontology, the Spanish Society of Palliative Care and the Section of Geriatric Cardiology of the Spanish Society of Cardiology. Its aim is to address the huge gap that exists in Spain with regard to the management of implantable cardioverter defibrillators (ICDs) in the final stages of life. It is increasingly common to find patients carrying these devices that are in the terminal stage of an advanced disease. This occurs in patients with advanced heart disease and subsequent heart failure refractory to treatment but also in a patient with an ICD who develops cancer disease, organ failure or other neurodegenerative diseases with poor short-term prognosis. The vast majority of these patients are over 65, so the paper focuses particularly on the elderly who are in this situation, but the decision-making process is similar in younger patients with ICDs who are in the final phase of their life. Copyright © 2013 SEGG. Published by Elsevier Espana. All rights reserved.

  9. Guidelines on the management of implantable cardioverter defibrillators at the end of life.

    Science.gov (United States)

    Datino, T; Rexach, L; Vidán, M T; Alonso, A; Gándara, Á; Ruiz-García, J; Fontecha, B; Martínez-Sellés, M

    2014-01-01

    This article is a joint document of the Spanish Society of Geriatrics and Gerontology, the Spanish Society of Palliative Care and the Section of Geriatric Cardiology of the Spanish Society of Cardiology. Its aim is to address the huge gap that exists in Spain with regard to the management of implantable cardioverter defibrillators (ICDs) in the final stages of life. It is increasingly common to find patients carrying these devices that are in the terminal stage of an advanced disease. This occurs in patients with advanced heart disease and subsequent heart failure refractory to treatment but also in a patient with an ICD who develops cancer disease, organ failure or other neurodegenerative diseases with poor short-term prognosis. The vast majority of these patients are over 65, so the paper focuses particularly on the elderly who are in this situation, but the decision-making process is similar in younger patients with ICDs who are in the final phase of their life. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  10. Interference of neodymium magnets with cardiac pacemakers and implantable cardioverter-defibrillators: an in vitro study.

    Science.gov (United States)

    Ryf, Salome; Wolber, Thomas; Duru, Firat; Luechinger, Roger

    2008-01-01

    Permanent magnets may interfere with the function of cardiac pacemakers and implantable cardioverter-defibrillators (ICDs). Neodymium-iron-boron (NdFeB) magnets have become widely available in recent years and are incorporated in various articles of daily life. We conducted an in-vitro study to evaluate the ability of NdFeB magnets for home and office use to cause interference with cardiac pacemakers and ICDs. The magnetic fields of ten NdFeB magnets of different size and shape were measured at increasing distances beginning from the surface until a field-strength (B-field) value of 0.5 mT was reached. Furthermore, for each magnet the distance was determined at which a sample pacemaker switched from magnet mode to normal mode. Depending on the size and remanence of individual magnets, a B-field value of 0.5 mT was found at distances ranging from 1.5 cm to 30 cm and a value of 1 mT at distances from 1 cm to 22 cm. The pacemaker behavior was influenced at distances from 1 cm to 24 cm. NdFeB magnets for home and office use may cause interference with cardiac pacemakers and ICDs at distances up to 24 centimeters. Patient education and product declarations should include information about the risk associated with these magnets.

  11. Driving safety among patients with automatic implantable cardioverter defibrillators.

    Science.gov (United States)

    Finch, N J; Leman, R B; Kratz, J M; Gillette, P C

    1993-10-06

    To determine the driving behavior of patients following the placement of automatic implantable cardioverter defibrillators (AICDs). Forty patients with AICDs (33 men, seven women; mean age, 62.7 years) responded to a questionnaire designed to ascertain driving behavior after hospital discharge. Despite medical advice never to drive again, 28 patients (70%) resumed driving, with the majority doing so by 8 months after AICD implantation. Of these, 11 (40%) identified themselves as the primary driver in their household. Fourteen (50%) drove daily. Two (7%) were driving and continued to drive during discharge of their AICDs. Twenty-five (91%) reported that they felt comfortable and safe while driving. A majority of patients with AICDs continue to drive after a proscription of this activity by health care workers.

  12. Impact of programming strategies aimed at reducing nonessential implantable cardioverter defibrillator therapies on mortality: a systematic review and meta-analysis.

    Science.gov (United States)

    Tan, Vern Hsen; Wilton, Stephen B; Kuriachan, Vikas; Sumner, Glen L; Exner, Derek V

    2014-02-01

    Patients who receive implantable cardioverter defibrillator therapies are at higher risk of death versus those who do not. Programmed settings to reduce nonessential implantable cardioverter defibrillator therapies (therapy reduction programming) have been developed but may have adverse effects. This systematic review and meta-analysis assessed the relationship between therapy reduction programming with the risks of death from any cause, implantable cardioverter defibrillator shocks, and syncope. MEDLINE, EMBASE, and clinicaltrials.gov databases were searched to identify relevant studies. Those that followed patients for ≥6 months and reported mortality were included. Six met the inclusion criteria; 4 randomized (Comparison of Empiric to Physician-Tailored Programming of ICDs [EMPIRIC], Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy [MADIT-RIT], Avoid Delivering Therapies for Non-sustained Arrhythmias in ICD Patients III [ADVANCE III], and Programming Implantable Cardioverter-Defibrillators in Patients with Primary Prevention Indication to Prolong Time to First Shock [PROVIDE]) and 2 prospective studies (Role of Long Detection Window Programming in Patients With Left Ventricular Dysfunction, Non-ischemic Etiology in Primary Prevention Treated with a Biventricular ICD [RELEVANT] and Primary Prevention Parameters Evaluation [PREPARE]). These 6 studies included 7687 (3598 conventional and 4089 therapy reduction programming) patients. Most (77%) participants were men, had a history of ischemic heart disease (56%), and were prescribed β-blockers (84%). Therapy reduction programming was associated with a 30% relative reduction in mortality (95% confidence interval, 16%-41%; Pprogramming (P=0.5). Therapy reduction programming results in a large, significant, and consistent reduction in mortality, with no apparent increase in the risk of syncope.

  13. Classic conditioning and dysfunctional cognitions in patients with panic disorder and agoraphobia treated with an implantable cardioverter/defibrillator.

    Science.gov (United States)

    Godemann, F; Ahrens, B; Behrens, S; Berthold, R; Gandor, C; Lampe, F; Linden, M

    2001-01-01

    A model for the development of anxiety disorders (panic disorder with or without agoraphobia) is needed. Patients with an implantable cardioverter/defibrillator (ICD) are exposed to repeated electric shocks. If the theory of anxiety development by aversive classic conditioning processes is valid, these repeated shocks should lead to an increased risk of anxiety disorders. To study this hypothesis, we retrospectively studied 72 patients after implantation of an automatic ICD. Patients were assessed with the semistructured Diagnostic Interview of Psychiatric Disease 1 to 6 years after implantation of an automatic ICD. Panic disorder and/or agoraphobia was diagnosed in patients who fulfilled all DSM-III-R criteria for those conditions. Anxiety disorder developed in 15.9% of patients after ICD implantation. This was significantly related to the frequency of repeated defibrillation (shocks) to stop malignant ventricular arrhythmias. Dysfunctional cognitions are an additional vulnerability factor. The data support both the conditioning hypothesis and the cognitive model of anxiety development. These findings suggest that ICD patients are an appropriate risk population for a prospective study of the development of anxiety disorders.

  14. Decision-Making of Patients With Implantable Cardioverter-Defibrillators at End of Life: Family Members' Experiences.

    Science.gov (United States)

    Lee, Mei Ching; Sulmasy, Daniel P; Gallo, Joseph; Kub, Joan; Hughes, Mark T; Russell, Stuart; Kellogg, Anela; Owens, Sharon G; Terry, Peter; Nolan, Marie T

    2017-07-01

    Many patients with advanced heart failure (HF) experience the life-extending benefits of implantable cardioverter-defibrillators (ICD), but at the end stage of HF, patients may experience shocks with increasing frequency and change the plan for end-of-life (EOL) care including the deactivation of the ICD. This report describes family members' experiences of patients with ICD making decisions at EOL. Understanding the decision-making of patients with ICD at EOL can promote informed decision-making and improve the quality of EOL care. This pilot study used a mixed methods approach to test the effects of a nurse-guided discussion in decision-making about ICD deactivation (turning off the defibrillation function) at the EOL. Interviews were conducted, audiotaped, and transcribed in 2012 to 2013 with 6 family members of patients with advanced HF and ICDs. Three researchers coded the data and identified themes in 2014. Three main themes described family members' experiences related to patients having HF with ICDs making health-care decision at EOL: decision-making preferences, patients' perception on ICD deactivation, and communication methods. Health-care providers need to have knowledge of patients' decision-making preferences. Preferences for decision-making include the allowing of appropriate people to involve and encourages direct conversation with family members even when advance directives is completed. Information of ICD function and the option of deactivation need to be clearly delivered to patients and family members. Education and guidelines will facilitate the communication of the preferences of EOL care.

  15. Safety of sports participation in patients with implantable cardioverter defibrillators: a survey of heart rhythm society members.

    Science.gov (United States)

    Lampert, Rachel; Cannom, David; Olshansky, Brian

    2006-01-01

    Safety of Sports for ICD Patients. The safety of sports participation for patients with implantable cardioverter defibrillators (ICDs) is unknown, and recommendations among physicians may vary widely. The purposes of this study were to determine current practice among patients with ICDs and their physicians regarding sports participation, and to determine how many physicians have cared for patients who have sustained adverse events during sports participation. A survey was mailed to all 1,687 U.S. physician members of the Heart Rhythm Society. Among 614 respondent physicians, recommendations varied widely. Only 10% recommended avoidance of all sports more vigorous than golf. Seventy-six percent recommended avoidance of contact, and 45% recommend avoidance of competitive sports. Most (71%) based restrictions on patients' underlying heart disease. Regardless of recommendations, most physicians (71%) reported caring for patients who participated in sports, including many citing vigorous, competitive sports, most commonly cited were basketball, running, and skiing. ICD shocks during sports were common, cited by 40% of physicians. However, few adverse consequences were reported. One percent of physicians reported known injury to patient (all but 3 minor); 5%, injury to the ICD system, and weightlifting and golf. Physician recommendations for sports participation for patients with ICDs varies widely. Many patients with ICDs do participate in vigorous and even competitive sports. While shocks were common, significant adverse events were rare.

  16. Prospective Randomized Evaluation of Implantable Cardioverter-Defibrillator Programming in Patients With a Left Ventricular Assist Device.

    Science.gov (United States)

    Richardson, Travis D; Hale, Leslie; Arteaga, Christopher; Xu, Meng; Keebler, Mary; Schlendorf, Kelly; Danter, Matthew; Shah, Ashish; Lindenfeld, JoAnn; Ellis, Christopher R

    2018-02-23

    Ventricular arrhythmias are common in patients with left ventricular assist devices (LVADs) but are often hemodynamically tolerated. Optimal implantable cardioverter defibrillator (ICD) tachy-programming strategies in patients with LVAD have not been determined. We sought to determine if an ultra-conservative ICD programming strategy in patients with LVAD affects ICD shocks. Adult patients with an existing ICD undergoing continuous flow LVAD implantation were randomized to standard ICD programming by their treating physician or an ultra-conservative ICD programming strategy utilizing maximal allowable intervals to detection in the ventricular fibrillation and ventricular tachycardia zones with use of ATP. Patients with cardiac resynchronization therapy (CRT) devices were also randomized to CRT ON or OFF. Patients were followed a minimum of 6 months. The primary outcome was time to first ICD shock. Among the 83 patients studied, we found no statistically significant difference in time to first ICD shock or total ICD shocks between groups. In the ultra-conservative group 16% of patients experienced at least one shock compared with 21% in the control group ( P =0.66). There was no difference in mortality, arrhythmic hospitalization, or hospitalization for heart failure. In the 41 patients with CRT ICDs fewer shocks were observed with CRT-ON but this was not statistically significant: 10% of patients with CRT-ON (n=21) versus 38% with CRT-OFF (n=20) received shocks ( P =0.08). An ultra-conservative programming strategy did not reduce ICD shocks. Programming restrictions on ventricular tachycardia and ventricular fibrillation zone therapy should be reconsidered for the LVAD population. The role of CRT in patients with LVAD warrants further investigation. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01977703. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  17. A patient with severely reduced LV function and electrical storm saved by wearable cardioverter-defibrillator: a case report.

    Science.gov (United States)

    Strauss, Margit; Kouraki, Kleopatra; Skarlos, Alexandros; Zahn, Ralf; Kleemann, Thomas

    2013-06-01

    The wearable cardioverter-defibrillator (WCD) is indicated in patients who are considered to be at temporarily high risk for sudden cardiac death (SCD), when an implantable defibrillator is not yet clearly indicated. We report the case of a 41-year-old patient with a newly diagnosed severely reduced left ventricular (LV) function for suspected myocarditis and repeated nonsustained ventricular tachycardia (VT). This patient was supplied with a WCD who came back to the hospital 4 weeks after discharge with an electrical storm and adequate discharge of the WCD. After application of amiodarone, no further arrhythmias were detected during intrahospital course. For further risk stratification, we performed a magnetic field imaging (MFI), that was reported to be useful in risk assessment of SCD in patients with ischemic cardiomyopathy. This measurement showed a normal result, but we decided to give an implantable cardioverter-defibrillator (ICD) to the patient. During a follow-up of 1 year, no further arrhythmias occurred. With this case, we report the efficacy of a WCD, which is a novel tool in patients at temporarily high risk of SCD and we report a novel method of risk stratification in patients with a high risk of SCD.

  18. Management of patients with implantable cardioverter-defibrillators and pacemakers who require radiation therapy.

    Science.gov (United States)

    Brambatti, Michela; Mathew, Rebecca; Strang, Barbara; Dean, Joan; Goyal, Anuja; Hayward, Joseph E; Long, Laurene; DeMeis, Patty; Smoke, Marcia; Connolly, Stuart J; Morillo, Carlos A; Amit, Guy; Capucci, Alessandro; Healey, Jeff S

    2015-10-01

    Radiation therapy (RT) may pose acute and long-term risks for patients with cardiac implantable electronic devices (CIEDs), including pacemakers (PMs) and implantable cardioverter-defibrillators (ICDs). However, the frequency of these problems has not been accurately defined. The purpose of this study was to determine the prevalence of CIEDs among patients requiring RT and report the common CIED-related problems when patients are managed according to a standard clinical care path. In a single tertiary-care center, we prospectively screened all patients requiring RT and identified patients with ICDs or PMs. We collected clinical data about their cancer, RT treatment plan, and CIED. Radiation dose to the device was estimated in all patients, and any device malfunction during RT was documented. Of the 34,706 consecutive patients receiving RT, 261 patients (0.8%, mean age 77.9 ± 9.4 years) had an implantable cardiac device: 54 (20.7%) ICDs and 207 (79.3%) PMs. The site of RT was head and neck (27.4%), chest (30.0%), and abdomen/pelvis (32.6%). Using our care path, 63.2% of patients required continuous cardiac monitoring, 14.6% required device reprogramming, 18.8% required magnet application during RT, and 3.4% required device repositioning to the contralateral side before RT. Four patients (1.5%) had inappropriate device function during RT: 3 experienced hemodynamically tolerated ventricular pacing at the maximum sensor rate, and 1 experienced a device power-on-reset. No patient died or suffered permanent device failure. Nearly 1% of patients receiving RT in this series has a PM or ICD. However, with a systematic policy of risk assessment and patient management, significant device-related complications are rare. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  19. Prognosis after implantation of cardioverter-defibrillators in Korean patients with Brugada syndrome.

    Science.gov (United States)

    Son, Myoung Kyun; Byeon, Kyeongmin; Park, Seung-Jung; Kim, June Soo; Nam, Gi-Byoung; Choi, Kee-Joon; Kim, You-Ho; Park, Sang Weon; Kim, Young-Hoon; Park, Hyung Wook; Cho, Jeong Gwan; On, Young Keun

    2014-01-01

    Our study aims to analyze prognosis after implantable cardioverter-defibrillator (ICD) implantation in Korean patients with Brugada syndrome (BrS). This was a retrospective study of BrS patients implanted with an ICD at one of four centers in Korea between January 1998 and April 2012. Sixty-nine patients (68 males, 1 female) were implanted with an ICD based on aborted cardiac arrest (n=38, 55%), history of syncope (n=17, 25%), or induced ventricular tachyarrhythmia on electrophysiologic study in asymptomatic patients (n=14, 20%). A family history of sudden cardiac death and a spontaneous type 1 electrocardiography (ECG) were noted in 13 patients (19%) and 44 patients (64%), respectively. During a mean follow-up of 59±46 months, 4.6±5.5 appropriate shocks were delivered in 19 patients (28%). Fourteen patients (20%) experienced 5.2±8.0 inappropriate shocks caused by supraventricular arrhythmia, lead failure, or abnormal sensing. Six patients were admitted for cardiac causes during follow-up, but no cardiac deaths occurred. An episode of aborted cardiac arrest was a significant predictor of appropriate shock, and the composite of cardiac events in the Cox proportional hazard model [hazard ratio (95% confidence interval) was 11.34 (1.31-97.94) and 4.78 (1.41-16.22), respectively]. However, a spontaneous type 1 ECG was not a predictor of cardiac events. Appropriate shock (28%) and inappropriate shock (20%) were noted during a mean follow-up of 59±46 months in Korean BrS patients implanted with an ICD. An episode of aborted cardiac arrest was the most powerful predictor of cardiac events.

  20. Thoracoscopic Left Cardiac Sympathetic Denervation for a Patient with Catecholaminergic Polymorphic Ventricular Tachycardia and Recurrent Implantable Cardioverter-Defibrillator Shocks

    Directory of Open Access Journals (Sweden)

    Woo-Sik Yu

    2015-06-01

    Full Text Available A patient presented with loss of consciousness and conversion. During an exercise test, catecholaminergic polymorphic ventricular tachycardia (CPVT resulted in cardiac arrest. He started taking medication (a beta-blocker and flecainide and an implantable cardioverter defibrillator (ICD was inserted, but the ventricular tachycardia did not resolve. Left cardiac sympathetic denervation (LCSD was then performed under general anesthesia, and the patient was discharged on the second postoperative day without complications. One month after the operation, no shock had been administered by the ICD, and an exercise stress test did not induce ventricular tachycardia. Although beta- blockers are the gold standard of therapy in patients with CPVT, thoracoscopic LCSD is safe and can be an effective alternative treatment option for patients with intractable CPVT.

  1. Radiotherapy and risk of implantable cardioverter-defibrillator malfunctions: experimental data from direct exposure at increasing doses.

    Science.gov (United States)

    Zecchin, Massimo; Artico, Jessica; Morea, Gaetano; Severgnini, Mara; Bianco, Elisabetta; De Luca, Antonio; Fantasia, Anna Zorzin; Salvatore, Luca; Milan, Vittorino; Lucarelli, Matteo; Dissegna, Roberta; Cannatà, Antonio; Sinagra, Gianfranco

    2018-04-01

    During radiotherapy, in patients with implantable cardioverter-defibrillators (ICDs) malfunctions are considered more likely if doses more than 2 Gy reach the ICD site; however, most malfunctions occur with high-energy (>10 MV) radiations, and the risk is less defined using 6-MV linear accelerators. The purpose of the study is to experimentally evaluate the occurrence of malfunctions in ICDs radiated with a 6-MV linear accelerator at increasing photon doses. Thirty-two ICDs from all manufacturers (31 explanted and one demo) were evaluated; all devices with a sufficient battery charge underwent multiple radiations with a 6-MV photon beam reaching a cumulative dose at ICD site of 0.5, 1, 2, 3, 5 and 10 Gy and interrogated after every session. All antitachycardia therapies were left enabled; two ICDs were connected to a rhythm simulator (one simulating a complete atrioventricular block without ventricular activity) and visually monitored by external ECG and the ICD programmer during radiation. Thirteen ICDs were excluded before radiation because of battery depletion; after radiation up to the cumulative dose at the cardiac implantable electronic device site of 10 Gy, in the remaining 19 devices, programmation and battery charge remained unchanged and no switch to safety mode was observed; oversensing, pacing inhibition or inappropriate antitachycardia therapy were neither recorded nor visually observed during radiation. With a low-energy accelerator, neither malfunctions nor electromagnetic interferences were detected radiating the ICDs at doses usually reaching the ICD pocket during radiotherapy sessions. In this context, magnet application to avoid oversensing and inappropriate therapy seems, therefore, useless.

  2. Attitudes of older adults with serious competing health risks toward their implantable cardioverter-defibrillators: a pilot study.

    Science.gov (United States)

    Green, Ariel R; Boyd, Cynthia M; Rickard, John; Gomon, Robert; Leff, Bruce

    2015-12-23

    In elderly heart failure patients, the survival benefit of implantable cardioverter-defibrillators (ICDs) may be attenuated due to competing health risks, and the risk of adverse outcomes magnified. Our objective was to examine older adults' attitudes towards ICD implantation in the context of competing health risks, exploring the determinants of ICD decision-making among a group of patients who had faced the decision in the past. Telephone survey with a qualitative component. Patients were age ≥70 with single- or dual-chamber ICDs from a single academic cardiac device clinic. Health status was assessed with the Vulnerable Elders Survey (VES-13). Responses to open-ended questions were transcribed verbatim; an "editing analysis" approach was used to extract themes. Forty-four ICD recipients participated (mean age 77.5 years). Nineteen participants (43%) had VES-13 scores ≥3, indicating a 50% likelihood of death or functional decline within 2 years. Twenty-one participants (48%) had received prior ICD shocks. Forty participants (91%) said they would "definitely" choose to get an ICD again in their current health. By and large, patients revealed a strong desire to extend life, expressed complete confidence in the lifesaving capabilities of their ICDs, and did not describe consideration of competing health risks. In this pilot telephone survey with a qualitative component, nearly all older adults with ICDs would still choose to get an ICD despite high short-term risk of death or health deterioration. These findings suggest the need to partner more effectively with patients and families to decide how best to use medical technologies, particularly for older adults with competing risks.

  3. Implantable cardioverter defibrillator therapy in pediatric and congenital heart disease patients: a single tertiary center experience in Korea

    Directory of Open Access Journals (Sweden)

    Bo Kyung Jin

    2013-03-01

    Full Text Available Purpose: The use of implantable cardioverter defibrillators (ICDs to prevent sudden cardiac death is increasing in children and adolescents. This study investigated the use of ICDs in children with congenital heart disease. Methods: This retrospective study was conducted on the clinical characteristics and effectiveness of ICD implantation at the department of pediatrics of a single tertiary center between 2007 and 2011. Results: Fifteen patients underwent ICD implantation. Their mean age at the time of implantation was 14.5±5.4 years (range, 2 to 22 years. The follow-up duration was 28.9±20.4 months. The cause of ICD implantation was cardiac arrest in 7, sustained ventricular tachycardia in 6, and syncope in 2 patients. The underlying disorders were as follows: ionic channelopathy in 6 patients (long QT type 3 in 4, catecholaminergic polymorphic ventricular tachycardia [CPVT] in 1, and J wave syndrome in 1, cardiomyopathy in 5 patients, and postoperative congenital heart disease in 4 patients. ICD coils were implanted in the pericardial space in 2 children (ages 2 and 6 years. Five patients received appropriate ICD shock therapy, and 2 patients received inappropriate shocks due to supraventricular tachycardia.During follow-up, 2 patients required lead dysfunction-related revision. One patient with CPVT suffered from an ICD storm that was resolved using sympathetic denervation surgery. Conclusion: The overall ICD outcome was acceptable in most pediatric patients. Early diagnosis and timely ICD implantation are recommended for preventing sudden death in high-risk children and patients with congenital heart disease.

  4. Is modification of the VVI backup mode in implantable cardioverter-defibrillators from St Jude medical required due to increased risk of inappropriate shocks?

    DEFF Research Database (Denmark)

    Philbert, Berit Thornvig; Tfelt-Hansen, Jacob; Jacobsen, Peter K

    2017-01-01

    Inappropriate implantable cardioverter-defibrillator (ICD) shock therapy is painful, stressful, and typically occurs unexpected in conscious patients and may be related to a less favourable prognosis. In our institution, we have observed four cases of multiple inappropriate ICD shocks during reset...... a ventricular fibrillation (VF) zone starting at 146 b.p.m., with shock therapy only and changes in sensitivity settings making the ICD more sensitive. In all cases, the reason for the multiple inappropriate shocks was that the VF zone was reached due to exercise-induced sinus tachycardia or due to oversensing...... during sinus rhythm. The VVI backup mode has to balance between protection from failure of ICD therapy during life-threatening ventricular arrhythmias and from inappropriate shocks. It seems the non-programmable parameters in VVI backup mode of St Jude Medical ICDs carry an unacceptable high risk...

  5. Use of implantable cardioverter defibrillators after out-of-hospital cardiac arrest: a prospective follow-up study

    Science.gov (United States)

    Parkash, Ratika; Tang, Anthony; Wells, George; Blackburn, Josée; Stiell, Ian; Simpson, Christopher; Dorian, Paul; Yee, Raymond; Cameron, Doug; Connolly, Stuart; Birnie, David; Nichol, Graham

    2004-01-01

    Background Survivors of out-of-hospital cardiac arrest are at high risk of recurrent arrests, many of which could be prevented with implantable cardioverter defibrillators (ICDs). We sought to determine the ICD insertion rate among survivors of out-of-hospital cardiac arrest and to determine factors associated with ICD implantation. Methods The Ontario Prehospital Advanced Life Support (OPALS) study is a prospective, multiphase, before–after study assessing the effectiveness of prehospital interventions for people experiencing cardiac arrest, trauma or respiratory arrest in 19 Ontario communities. We linked OPALS data describing survivors of cardiac arrest with data from all defibrillator implantation centres in Ontario. Results From January 1997 to April 2002, 454 patients in the OPALS study survived to hospital discharge after experiencing an out-of-hospital cardiac arrest. The mean age was 65 (standard deviation 14) years, 122 (26.9%) were women, 398 (87.7%) had a witnessed arrest, 372 (81.9%) had an initial rhythm of ventricular tachycardia or ventricular fibrillation (VT/VF), and 76 (16.7%) had asystole or another arrhythmia. The median cerebral performance category at discharge (range 1–5, 1 = normal) was 1. Only 58 (12.8%) of the 454 patients received an ICD. Patients with an initial rhythm of VT/VF were more likely than those with an initial rhythm of asystole or another rhythm to undergo device insertion (adjusted odds ratio [OR] 9.63, 95% confidence interval [CI] 1.31–71.50). Similarly, patients with a normal cerebral performance score were more likely than those with abnormal scores to undergo ICD insertion (adjusted OR 12.52, 95% CI 1.74–92.12). Interpretation A minority of patients who survived cardiac arrest underwent ICD insertion. It is unclear whether this low usage rate reflects referral bias, selection bias by electrophysiologists, supply constraint or patient preference. PMID:15505267

  6. Importance of the atrial channel for ventricular arrhythmia therapy in the dual chamber implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2000-12-01

    Performance of dual chamber implantable cardioverter defibrillator (ICD) systems has been judged based on functioning of the ventricular tachycardia:supraventricular tachycardia (VT:SVT) discrimination criteria and DDD pacing. The purpose of this study was to evaluate the use of dual chamber diagnostics to improve the electrical and antiarrhythmic therapy of ventricular arrhythmias. Information about atrial and ventricular rhythm in relation to ventricular arrhythmia occurrence and therapy was evaluated in 724 spontaneous arrhythmia episodes detected and treated by three types of dual chamber ICDs in 41 patients with structural heart disease. Device programming was based on clinically documented and induced ventricular arrhythmias. In ambulatory patients, sinus tachycardia preceded ventricular arrhythmias more often than in the hospital during exercise testing. The incidence of these VTs could be reduced by increasing the dose of a beta-blocking agent in only two patients. In five patients in whom sinus tachycardia developed after onset of hemodynamic stable VT, propranolol was more effective than Class III antiarrhythmics combined with another beta-blocking agent with regard to the incidence of VT and pace termination. In all but three cases, atrial arrhythmias were present for a longer time before the onset of ventricular arrhythmias. During atrial arrhythmias, fast ventricular rates before the onset of ventricular rate were observed more often than RR irregularities and short-long RR sequences. Dual chamber diagnostics allowed proper interpretation of detection and therapy outcome in patients with different types of ventricular arrhythmia. The advantages of the dual chamber ICD system go further than avoiding the shortcomings of the single chamber system. Information from the atrial chamber allows better device programming and individualization of drug therapy for ventricular arrhythmia.

  7. Optimizing implantable cardioverter-defibrillator treatment of rapid ventricular tachycardia: antitachycardia pacing therapy during charging.

    Science.gov (United States)

    Schoels, Wolfgang; Steinhaus, David; Johnson, W Ben; O'hara, Gilles; Schwab, Joerg O; Jenniskens, Inge; Degroot, Paul J; Tang, Feng; Helmling, Erhard

    2007-07-01

    Previous studies in implantable cardioverter-defibrillator (ICD) patients demonstrated the efficacy and safety of antitachycardia pacing (ATP) for rapid ventricular tachycardias (VT). To prevent shock delay in case of ATP failure, a new feature (ATP during charging) was developed to deliver ATP for rapid VT while charging for shock. The purpose of this study was to determine the efficacy and safety of this new feature. In a prospective, nonrandomized trial, patients with standard ICD indication received an EnTrust ICD. VT and ventricular fibrillation (VF) episodes were reviewed for appropriate detection, ATP success, rhythm acceleration, and related symptoms. In 421 implanted patients, 116 VF episodes occurred in 37 patients. Eighty-four (72%) episodes received ATP during or before charging. ATP prevented a shock in 58 (69%) of 84 episodes in 15 patients. ATP stopped significantly more monomorphic (77%) than polymorphic VTs (44%, P = .05). Five (6%) episodes accelerated after ATP but were terminated by the backup shock(s). No symptoms were related to ATP during charging. In four patients, 38 charges were saved by delivering ATP before charging. Of 98 induced VF episodes, 28% were successfully terminated by ATP versus 69% for spontaneous episodes (P <.01). Most VTs detected in the VF zone can be painlessly terminated by ATP delivered during charging, with a low risk of acceleration or symptoms. ATP before charging allows delivery of two ATP attempts before shock in the same time that would otherwise be required to deliver only one ATP plus a shock. It also offers potential battery energy savings.

  8. Development and testing of an algorithm to detect implantable cardioverter-defibrillator lead failure.

    Science.gov (United States)

    Gunderson, Bruce D; Gillberg, Jeffrey M; Wood, Mark A; Vijayaraman, Pugazhendhi; Shepard, Richard K; Ellenbogen, Kenneth A

    2006-02-01

    Implantable cardioverter-defibrillator (ICD) lead failures often present as inappropriate shock therapy. An algorithm that can reliably discriminate between ventricular tachyarrhythmias and noise due to lead failure may prevent patient discomfort and anxiety and avoid device-induced proarrhythmia by preventing inappropriate ICD shocks. The goal of this analysis was to test an ICD tachycardia detection algorithm that differentiates noise due to lead failure from ventricular tachyarrhythmias. We tested an algorithm that uses a measure of the ventricular intracardiac electrogram baseline to discriminate the sinus rhythm isoelectric line from the right ventricular coil-can (i.e., far-field) electrogram during oversensing of noise caused by a lead failure. The baseline measure was defined as the product of the sum (mV) and standard deviation (mV) of the voltage samples for a 188-ms window centered on each sensed electrogram. If the minimum baseline measure of the last 12 beats was algorithm to detect lead failures. The minimum baseline measure for the 24 lead failure episodes (0.28 +/- 0.34 mV-mV) was smaller than the 135 ventricular tachycardia (40.8 +/- 43.0 mV-mV, P <.0001) and 55 ventricular fibrillation episodes (19.1 +/- 22.8 mV-mV, P <.05). A minimum baseline <0.35 mV-mV threshold had a sensitivity of 83% (20/24) with a 100% (190/190) specificity. A baseline measure of the far-field electrogram had a high sensitivity and specificity to detect lead failure noise compared with ventricular tachycardia or fibrillation.

  9. Association of psychiatric history and type D personality with symptoms of anxiety, depression, and health status prior to ICD implantation

    DEFF Research Database (Denmark)

    Starrenburg, Annemieke H; Kraaier, Karin; Pedersen, Susanne S.

    2013-01-01

    Personality factors and psychiatric history may help explain individual differences in risk of psychological morbidity and poor health outcomes in patients with an implantable cardioverter defibrillator (ICD).......Personality factors and psychiatric history may help explain individual differences in risk of psychological morbidity and poor health outcomes in patients with an implantable cardioverter defibrillator (ICD)....

  10. Beta-blocker therapy is not associated with symptoms of depression and anxiety in patients receiving an implantable cardioverter-defibrillator.

    Science.gov (United States)

    Hoogwegt, Madelein T; Kupper, Nina; Theuns, Dominic A M J; Jordaens, Luc; Pedersen, Susanne S

    2012-01-01

    Beta-blockers are frequently prescribed to implantable cardioverter-defibrillator (ICD) patients. Beta-blocker therapy has been proposed to induce emotional distress such as depression and anxiety, but a paucity of studies has examined the relationship between beta-blockers and distress. We investigated the association between beta-blocker therapy, including type and dosage, and symptoms of anxiety and depression in a consecutive cohort of patients receiving an ICD. Between 2003 and 2010, 448 consecutively implanted ICD patients were enrolled in the prospective Mood and personality as precipitants of arrhythmia in patients with an Implantable cardioverter Defibrillator: A prospective Study (MIDAS), of which 429 completed the Hospital Anxiety and Depression Scale (HADS) and the ICD Patient Concerns questionnaire (ICDC) at baseline. Eighty per cent of all patients received beta-blocker therapy. In univariate analysis, beta-blocker therapy was not significantly associated with symptoms of anxiety, depression, and ICD concerns (β = -0.030, β = 0.007, and β = -0.045, respectively; all P's >0.36). Type of beta-blocker showed a trend towards significance for mean levels of ICD concerns (P = 0.09). No association was found between dosage and emotional distress (all P's >0.21). After adjustment for relevant clinical and demographic variables, the association of beta-blocker therapy and symptoms of anxiety, depression, and ICD concerns remained non-significant (β = 0.009, β = 0.037, and β = 0.019, respectively; all P's >0.47). In patients receiving an ICD, beta-blocker therapy was not associated with symptoms of anxiety, depression, and ICD concerns. Research is warranted that further elucidates the link between beta-blocker therapy and emotional distress in this vulnerable patient group.

  11. A comparison of the health status and psychological distress of partners of patients with a left ventricular assist device versus an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Brouwers, Corline; Caliskan, Kadir; de Jonge, Nicolaas

    2014-01-01

    (F = 10.71, p = .001) but poorer mental health status (F = 14.82, p depression scores compared to ICD partners (F = 3.68, p = .05) at 6 months follow-up, also in adjusted analyses. There was no significant difference between groups on anxiety. CONCLUSION: Caregivers of LVAD......OBJECTIVE: To examine if the caregiving for patients with a left ventricular assist device (LVAD) is related to a poorer health status and more distress compared to patients with an implantable cardioverter defibrillator (ICD). BACKGROUND: Partners distress may influence patient outcomes...... and is therefore an important aspect in the care of LVAD and ICD patients. METHODS: Multi-center prospective observational study with 6 months follow-up of 33 LVAD partners (27% men; mean age = 54 ± 10 years) and 414 ICD partners (22% men; mean age = 60 ± 12 years). RESULTS: LVAD partners reported better physical...

  12. In vitro assessment of the immunity of implantable cardioverter-defibrillators to magnetic fields of 50/60 Hz.

    Science.gov (United States)

    Katrib, J; Nadi, M; Kourtiche, D; Magne, I; Schmitt, P; Souques, M; Roth, P

    2013-10-01

    Public concern for the compatibility of electromagnetic (EM) sources with active implantable medical devices (AIMD) has prompted the development of new systems that can perform accurate exposure studies. EM field interference with active cardiac implants (e.g. implantable cardioverter-defibrillators (ICDs)) can be critical. This paper describes a magnetic field (MF) exposure system and the method developed for testing the immunity of ICD to continuous-wave MFs. The MFs were created by Helmholtz coils, housed in a Faraday cage. The coils were able to produce highly uniform MFs up to 4000 µT at 50 Hz and 3900 µT at 60 Hz, within the test space. Four ICDs were tested. No dysfunctions were found in the generated MFs. These results confirm that the tested ICDs were immune to low frequency MFs.

  13. Clinical predictors and prognostic significance of electrical storm in patients with implantable cardioverter defibrillators.

    Science.gov (United States)

    Brigadeau, François; Kouakam, Claude; Klug, Didier; Marquié, Christelle; Duhamel, Alain; Mizon-Gérard, Frédérique; Lacroix, Dominique; Kacet, Salem

    2006-03-01

    Insufficient data exists regarding predictors of electrical storms (ES) and clinical outcome in patients treated with an implantable cardioverter defibrillator (ICD). The purpose of this study was to delineate a subgroup of patients likely to experience ES and to determine the impact of ES on mortality in ICD recipients. Baseline characteristics of 307 ICD-treated patients were retrospectively analysed. ES was defined as two or more ventricular tachyarrhythmias within 24 h leading to an immediate electrical therapy (antitachycardia pacing and/or shock), separated by a period of sinus rhythm. Clinical characteristics and survival of 123 patients experiencing a total of 294 episodes of ES (median 2 ES/patient, range 1-9), were compared with those of 184 ES-free patients during a median follow-up of 826 days (inter-quartile 1141 days). Median actuarial duration for the first ES occurrence after ICD implant was 1417 days [95% confidence interval (CI) 1061-2363] with a median follow-up of 816 days (7-4642 days) in ES-free patients. Univariate analysis identified older age, depressed left ventricular ejection fraction (LVEF), ventricular tachycardia (VT) as index arrhythmia, chronic renal failure and absence of lipid-lowering drugs as variables significantly associated with an increased risk of ES. Multivariable Cox analysis confirmed an independent predictive value for chronic renal failure [hazard ratio (HR) 1.54, 95% CI 0.95-2.51, P=0.052], VT (HR 2.20, 95% CI 1.44-3.37, P=0.0003), and LVEF (HR 0.98, 95% CI 0.97-0.99, P=0.027). In contrast, diabetics (HR 0.49, 95% CI 0.27-0.90, P=0.022) were less affected by ES. There was no difference in survival between both groups. ES is frequent but does not increase mortality in ICD's recipients. Patients with severe systolic dysfunction, chronic renal failure and VT as initial arrhythmia are likely to experience ES. Diabetics are less affected by ES.

  14. Canadian Registry of ICD Implant Testing procedures (CREDIT): current practice, risks, and costs of intraoperative defibrillation testing.

    Science.gov (United States)

    Healey, Jeff S; Dorian, Paul; Mitchell, L Brent; Talajic, Mario; Philippon, Francois; Simpson, Chris; Yee, Raymond; Morillo, Carlos A; Lamy, Andre; Basta, Magdy; Birnie, David H; Wang, Xiaoyin; Nair, Girish M; Crystal, Eugene; Kerr, Charles R; Connolly, Stuart J

    2010-02-01

    There is uncertainty about the proper role of defibrillation testing (DT) at the time of implantable cardioverter defibrillator (ICD) insertion. A prospective registry was conducted at 13 sites in Canada between January 2006 and October 2007. To document the details of DT, the reasons for not conducting DT, and the costs and complications associated with DT. DT was conducted at implantation in 230 of 361 patients (64%). DT was more likely to be conducted for new implants compared with impulse generator replacements (71% vs 32%, P = 0.0001), but was similar for primary and secondary prevention indications (64% vs 63%, P = NS). Among patients not having DT, the reason(s) given were: considered unnecessary (44%); considered unsafe, mainly due to persistent atrial fibrillation (37%); lack of an anesthetist (20%); and, patient or physician preference (6%). When performed, DT consisted of a single successful shock > or = 10J below maximum device output in 65% of cases. A 10J safety-margin was met by 97% of patients, requiring system modification in 2.3%. Major perioperative complications occurred in 4.4% of patients having DT versus 6.6% of patients not having DT (P = NS). ICD insertion was $844 more expensive for patients having DT (P = 0.16), largely due to increased costs ($28,017 vs $24,545) among patients having impulse generator replacement (P = 0.02). DT was not performed in a third of ICD implants, usually due to a perceived lack of need or relative contraindication.

  15. Value of Serial Heart Rate Variability Measurement for Prediction of Appropriate ICD Discharge in Patients with Heart Failure

    NARCIS (Netherlands)

    ten Sande, Judith N.; Damman, Peter; Tijssen, Jan G. P.; de Groot, Joris R.; Knops, Reinoud E.; Wilde, Arthur A. M.; van Dessel, Pascal F. H. M.

    2014-01-01

    HRV and Appropriate ICD Shock in Heart Failure Introduction Decreased heart rate variability (HRV) is associated with adverse outcomes in patients with heart failure. Our objective was to examine whether decreased HRV predicts appropriate implantable cardioverter defibrillator (ICD) shocks. Methods

  16. Inappropriate shock delivery by implantable cardioverter defibrillator due to electrical interference with washing machine.

    Science.gov (United States)

    Chongtham, Dhanaraj Singh; Bahl, Ajay; Kumar, Rohit Manoj; Talwar, K K

    2007-05-31

    We report a patient with hypertrophic cardiomyopathy who received an inappropriate implantable cardioverter defibrillator shock due to electrical interference from a washing machine. This electrical interference was detected as an episode of ventricular fibrillation with delivery of shock without warning symptoms.

  17. Ventricular tachyarrhythmias and mortality in patients with an implantable cardioverter defibrillator: impact of depression in the MIDAS cohort.

    Science.gov (United States)

    Mastenbroek, Mirjam H; Versteeg, Henneke; Jordaens, Luc; Theuns, Dominic A M J; Pedersen, Susanne S

    2014-01-01

    We examined whether depression is independently associated with implantable cardioverter defibrillator (ICD) therapy for ventricular tachyarrhythmias and mortality. A cohort of 430 consecutive patients with a first-time ICD (79% men; mean [standard deviation] age = 57.8 [12.1] years) completed the Hospital Anxiety and Depression Scale 1 day before implantation. During follow-up, the ICD was interrogated at 3-month intervals. Cox proportional hazard regression analyses were used to examine the impact of depression on time to first appropriate ICD therapy and all-cause mortality during a median follow-up period of 3.8 years. Of all patients, 108 (25.1%) were depressed. Depression was not associated with time to first appropriate ICD therapy (unadjusted hazard ratio [HR] = 1.07, 95% confidence interval [CI] = 0.73-1.56). However, depression was associated with an increased risk for all-cause mortality (unadjusted HR = 2.18, 95% CI = 1.36-3.49). Depression remained independently associated with all-cause mortality (HR = 1.94, 95% CI = 1.06-3.54, p = .031), after adjusting for demographic and clinical characteristics. Patients who remained depressed during the first 3 months after implantation were at greatest risk for dying (HR = 2.88, 95% CI = 1.29-6.45, p = .010). The current study showed that depression at the time of implant is not associated with time to first appropriate ICD therapy but almost doubled the risk for all-cause mortality in patients with an ICD. Patients with persistent depression during the first 3 months after implantation face the greatest risk of dying. Current evidence indicates that multifactorial interventions are likely to be the most successful in terms of reducing distress. Whether this translates into enhanced survival has yet to be determined.

  18. Diagnosis and therapy of atrial tachyarrhythmias in the dual chamber implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2000-11-01

    Devices capable of monitoring and treating atrial tachyarrhythmias provide information about the natural history of the arrhythmias and potentially can influence their natural course by electrical therapy early after onset. Types of atrial arrhythmias and efficacy of device therapies were evaluated in 30 patients implanted with the Medtronic model 7250 Jewel AF implantable cardioverter defibrillator (ICD). All patients had structural heart disease and documented sustained ventricular and atrial arrhythmias (27 with atrial fibrillation [AF]) before implant. Twenty patients were taking amiodarone, and three were taking sotalol. During 20+/-10 months of follow-up, 600 atrial arrhythmia recurrences were documented in 50% of patients. AF was diagnosed in 19%, fast polymorphic atrial tachycardia (AT) in 20%, fast monomorphic AT in 57%, and slow AT in 4% of episodes. The two adaptive pacing therapies, burst and ramp, together with the 50-Hz burst, were successful in 57% of detected atrial arrhythmias. Burst and ramp were responsible for 49% and 50-Hz burst for 51% of successfully treated arrhythmias; 33% of the episodes terminated spontaneously. No ventricular proarrhythmia was observed due to atrial pacing therapies. In 30% of episodes, dual chamber pacing was required due to post termination bradycardia. Atrial arrhythmia recurrences in patients with dilated cardiomyopathy were not amenable to pacing therapies. Several aspects of atrial arrhythmia diagnosis, therapy, and documentation that are specific for functioning of the Jewel AF are discussed. Atrial arrhythmias in ICD patients with diseased hearts who are taking Class III antiarrhythmics frequently had longer cycle lengths than AF. Half of these arrhythmias could be terminated with pacing therapies; one third terminated spontaneously.

  19. Is it safe to allow patients with implantable cardioverter-defibrillators to drive? Learnings from a single center experience.

    Science.gov (United States)

    Curnis, Antonio; Mascioli, Giosue; Bontempi, Luca; Cerini, Manuel; Bignotti, Tommaso; Bonetti, Gabriele; Dei Cas, Livio

    2008-12-01

    Implantable cardioverter-defibrillator (ICD) implant indications have widened in recent years after the publication of the Multicenter Automatic Defibrillator Implantation Trial 2 and the Sudden Cardiac Death in Heart Failure Trial. On the contrary, guidelines on resumption of driving after ICD implant were published almost 10 years ago when the ICD implant rate was much lower and candidates were generally older. The overall objective of our study was to evaluate whether patients implanted with ICDs have higher risk than the general driving population. The specific aim of the study was to verify the rate of car accidents in patients implanted with an ICD, both for primary and secondary indication, and compare this with the rate of accidents in the general population. The primary end point of the study was the annual car accident rate; the secondary end point was to determine if there were subgroups of patients with a higher risk of car accidents. All patients (612) followed up in our outpatient clinic were sent a questionnaire in which they were asked five questions regarding their driving habits before and after ICD implant and, specifically, whether they had been involved in a car accident after the implant. Two hundred eighty-six patients (47%) responded to the questionnaire. Seventy-one patients had never driven; two patients were forbidden to drive for professional reasons (one bus and one truck driver). Two hundred thirteen (74.5% of all responding) patients (201 men, mean age 62 +/- 11 years) continued to drive after ICD implant. During the follow-up (1430 +/- 920 days) 11 patients had been involved in car accidents and, importantly 10 out of 11 were innocent bystanders. Thus, in 996 patient-years, 11 events happened, yielding an annual event rate of 1.1% per patient-years (and only 0.1% in which the driver could had been responsible). Car accidents are infrequent in patients implanted with an ICD, and - in any case - not more frequent than in the general

  20. Risk of pacemaker or implantable cardioverter defibrillator after radiotherapy for early-stage breast cancer in Denmark, 1982-2005

    DEFF Research Database (Denmark)

    Rehammar, Jens Christian; Johansen, Jens Brock; Jensen, Maj-Britt

    2017-01-01

    BACKGROUND AND PURPOSE: To examine the risk of cardiac conduction abnormalities or severe ventricular arrhythmias requiring implantation of a cardiac implantable electronic device (CIED), either a pacemaker or an implantable cardioverter-defibrillator, subsequent to breast cancer (BC) radiotherapy...... (RT). MATERIAL AND METHODS: All women treated for early-stage BC in Denmark from 1982 to 2005 were identified from the Danish Breast Cancer Cooperative Group. By record linkage to the Danish Pacemaker and ICD Registry information was retrieved on CIED implants subsequent to RT. Standardized incidence...... ratios (SIR) of CIED implantation were estimated for women receiving RT and compared to women not receiving RT for BC. Uni- and multivariate Poisson regression models were used to estimate incidence rate ratios (IRR) among irradiated women compared to non-irradiated. RESULTS: Of 44,423 BC patients, 179...

  1. Psychometric analysis of the Patient Health Questionnaire in Danish patients with an implantable cardioverter defibrillator (The DEFIB-WOMEN study)

    DEFF Research Database (Denmark)

    Pedersen, Susanne S; Mathiasen, Kim; Christensen, Karl Bang

    2016-01-01

    OBJECTIVE: To assess the psychometric properties of the Patient Health Questionnaire (PHQ-9), a measure of depressive symptoms, in a large Danish national cohort of patients with heart disease, implanted with an implantable cardioverter defibrillator (ICD), using item response theory. METHODS: A ...... of nine items for the partial credit model and five of nine items for the generalized partial credit model, indicating that respondents have difficulty discriminating between response options. When collapsing response options 2 and 3, the rescored PHQ-9 had a better fit to both models....... Three items did not fit the partial credit model, but the generalized partial credit model could be fitted to the full item set. CONCLUSION: The unidimensionality and reliability of the Danish version of the PHQ-9 were confirmed. However, the associated consequences of the number of response options (3...

  2. Questions to Ask Your Doctor--Implantable Cardioverter Defibrillator (ICD)

    Science.gov (United States)

    ... family member or I still drive, travel, have sex, work out or continue other activities we enjoy? How ... in Children • Arrhythmia Tools & Resources Answers by Heart Fact Sheets Learn and live with our downloadable patient ...

  3. Appropriate evaluation and treatment of heart failure patients after implantable cardioverter-defibrillator discharge: time to go beyond the initial shock.

    Science.gov (United States)

    Mishkin, Joseph D; Saxonhouse, Sherry J; Woo, Gregory W; Burkart, Thomas A; Miles, William M; Conti, Jamie B; Schofield, Richard S; Sears, Samuel F; Aranda, Juan M

    2009-11-24

    Multiple clinical trials support the use of implantable cardioverter-defibrillators (ICDs) for prevention of sudden cardiac death in patients with heart failure (HF). Unfortunately, several complicating issues have arisen from the universal use of ICDs in HF patients. An estimated 20% to 35% of HF patients who receive an ICD for primary prevention will experience an appropriate shock within 1 to 3 years of implant, and one-third of patients will experience an inappropriate shock. An ICD shock is associated with a 2- to 5-fold increase in mortality, with the most common cause being progressive HF. The median time from initial ICD shock to death ranges from 168 to 294 days depending on HF etiology and the appropriateness of the ICD therapy. Despite this prognosis, current guidelines do not provide a clear stepwise approach to managing these high-risk patients. An ICD shock increases HF event risk and should trigger a thorough evaluation to determine the etiology of the shock and guide subsequent therapeutic interventions. Several combinations of pharmacologic and device-based interventions such as adding amiodarone to baseline beta-blocker therapy, adjusting ICD sensitivity, and employing antitachycardia pacing may reduce future appropriate and inappropriate shocks. Aggressive HF surveillance and management is required after an ICD shock, as the risk of sudden cardiac death is transformed to an increased HF event risk.

  4. Educational and psychological interventions to improve outcomes for recipients of implantable cardioverter defibrillators and their families: a scientific statement from the American Heart Association.

    Science.gov (United States)

    Dunbar, Sandra B; Dougherty, Cynthia M; Sears, Samuel F; Carroll, Diane L; Goldstein, Nathan E; Mark, Daniel B; McDaniel, George; Pressler, Susan J; Schron, Eleanor; Wang, Paul; Zeigler, Vicki L

    2012-10-23

    Significant mortality benefits have been documented in recipients of implantable cardioverter defibrillators (ICDs); however, the psychosocial distress created by the underlying arrhythmia and its potential treatments in patients and family members may be underappreciated by clinical care teams. The disentanglement of cardiac disease and device-related concerns is difficult. The majority of ICD patients and families successfully adjust to the ICD, but optimal care pathways may require additional psychosocial attention to all ICD patients and particularly those experiencing psychosocial distress. This state-of-the-science report was developed on the basis of an analysis and critique of existing science to (1) describe the psychological and quality-of-life outcomes after receipt of an ICD and describe related factors, such as patient characteristics; (2) describe the concerns and educational/informational needs of ICD patients and their family members; (3) outline the evidence that supports interventions for improving educational and psychological outcomes for ICD patients; (4) provide recommendations for clinical approaches for improving patient outcomes; and (5) identify priorities for future research in this area. The ultimate goal of this statement is to improve the precision of identification and care of psychosocial distress in ICD patients to maximize the derived benefit of the ICD.

  5. Evaluation of acute cardiac and chest wall damage after shocks with a subcutaneous implantable cardioverter defibrillator in Swine.

    Science.gov (United States)

    Killingsworth, Cheryl R; Melnick, Sharon B; Litovsky, Silvio H; Ideker, Raymond E; Walcott, Gregory P

    2013-10-01

    A subcutaneous implantable cardioverter defibrillator (S-ICD) could ease placement and reduce complications of transvenous ICDs, but requires more energy than transvenous ICDs. Therefore we assessed cardiac and chest wall damage caused by the maximum energy shocks delivered by both types of clinical devices. During sinus rhythm, anesthetized pigs (38 ± 6 kg) received an S-ICD (n = 4) and five 80-Joule (J) shocks, or a transvenous ICD (control, n = 4) and five 35-J shocks. An inactive S-ICD electrode was implanted into the same control pigs to study implant trauma. All animals survived 24 hours. Troponin I and creatine kinase muscle isoenzyme (CK-MM) were measured as indicators of myocardial and skeletal muscle injury. Histopathological injury of heart, lungs, and chest wall was assessed using semiquantitative scoring. Troponin I was significantly elevated at 4 hours and 24 hours (22.6 ± 16.3 ng/mL and 3.1 ± 1.3 ng/mL; baseline 0.07 ± 0.09 ng/mL) in control pigs but not in S-ICD pigs (0.12 ± 0.11 ng/mL and 0.13 ± 0.13 ng/mL; baseline 0.06 ± 0.03 ng/mL). CK-MM was significantly elevated in S-ICD pigs after shocks (6,544 ± 1,496 U/L and 9,705 ± 6,240 U/L; baseline 704 ± 398 U/L) but not in controls. Electrocardiogram changes occurred postshock in controls but not in S-ICD pigs. The myocardium and lungs were histologically normal in both groups. Subcutaneous injury was greater in S-ICD compared to controls. Although CK-MM suggested more skeletal muscle injury in S-ICD pigs, significant cardiac, lung, and chest wall histopathological changes were not detected in either group. Troponin I data indicate significantly less cardiac injury from 80-J S-ICD shocks than 35-J transvenous shocks. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  6. Evaluation of acute cardiac and chest wall damage after shocks with a subcutaneous implantable cardioverter-defibrillator in swine

    Science.gov (United States)

    KILLINGSWORTH, CHERYL R.; MELNICK, SHARON B.; LITOVSKY, SILVIO H.; IDEKER, RAYMOND E.; WALCOTT, GREGORY P.

    2013-01-01

    Background A subcutaneous implantable cardioverter defibrillator (S-ICD) could ease placement and reduce complications of transvenous ICDs, but requires more energy than transvenous ICDs. Therefore we assessed cardiac and chest wall damage caused by the maximum energy shocks delivered by both types of clinical devices. Methods During sinus rhythm, anesthetized pigs (38±6 kg) received an S-ICD (n = 4) and five 80-Joule (J) shocks, or a transvenous ICD (control, n = 4) and five 35-J shocks. An inactive S-ICD electrode was implanted into the same control pigs to study implant trauma. All animals survived 24-hours. Troponin I and creatine kinase muscle isoenzyme (CK-MM) were measured as indicators of myocardial and skeletal muscle injury. Histopathological injury of heart, lungs, and chest wall was assessed using semi-quantitative scoring. Results Troponin I was significantly elevated at 4- and 24-hours (22.6±16.3 and 3.1±1.3 ng/ml; baseline 0.07±0.09 ng/ml) in control pigs but not in S-ICD pigs (0.12±0.11 and 0.13±0.13 ng/ml; baseline 0.06±0.03 ng/ml). CK-MM was significantly elevated in S-ICD pigs after shocks (6544±1496 and 9705±6240 U/L; baseline 704±398 U/L) but not in controls. ECG changes occurred post-shock in controls but not in S-ICD pigs. The myocardium and lungs were histologically normal in both groups. Subcutaneous injury was greater in S-ICD compared to controls. Conclusion Although CK-MM suggested more skeletal muscle injury in S-ICD pigs, significant cardiac, lung, and chest wall histopathological changes were not detected in either group. Troponin I data indicate significantly less cardiac injury from 80-J S-ICD shocks than 35-J transvenous shocks. PMID:23713608

  7. Do implantable cardioverter defibrillators improve survival in patients with severe left ventricular systolic dysfunction after coronary artery bypass graft surgery?

    Science.gov (United States)

    Fazal, Iftikhar A; Bates, Matthew G D; Matthews, Iain G; Turley, Andrew J

    2011-06-01

    A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was whether implantable cardioverter defibrillators (ICD) improve survival in patients with severe left ventricular systolic dysfunction (LVSD) after coronary artery bypass graft (CABG) surgery. ICDs are designed to terminate potentially fatal cardiac tachyarrhythmias. A right ventricular lead is mandatory for detection, pacing and defibrillation capabilities. Dual chamber ICDs have an additional right atrial lead and are used for patients with conventional atrioventricular pacing indications. More sophisticated, biventricular devices exist to provide cardiac resynchronisation therapy (CRT) in addition to defibrillation (CRT-D). ICDs have been extensively investigated in patients with LVSD post myocardial infarction and in patients with non-ischaemic cardiomyopathy for both secondary prevention (history of ventricular arrhythmias) and primary prevention (deemed high risk for ventricular arrhythmias). This best evidence topic aims to review the evidence and its applicability to patients post CABG. Nine hundred and sixteen papers were identified using the search method outlined. Eight randomised controlled trials, two meta-analyses, and one non-randomised trial, in addition to international guidelines presented the best evidence to answer the clinical question. The current evidence base and guidelines suggest that ICDs should be considered for all patients with LVSD [ejection fraction (EF) ≤30-40%] receiving optimal pharmacological management, who are ≥40 days post MI [four weeks for National Institute for Health and Clinical Excellence (NICE)] and in New York Heart Association (NYHA) class I-III. UK NICE guidelines require in addition; non-sustained ventricular tachycardia (NSVT) on a Holter monitor and inducible ventricular tachycardia at electrophysiological study for EF between 30 and 35%; or a QRS >120 ms if EF <30%. The North American guidelines

  8. “Atrial torsades de pointes” Induced by Low-Energy Shock From Implantable-Cardioverter Defibrillator

    Directory of Open Access Journals (Sweden)

    Ilknur Can, MD

    2013-09-01

    Full Text Available A 58 year-old-patient developed an episode of polymorphic atrial tachycardia which looked like "atrial torsades de pointes" after a 5J shock from implantable cardioverter defibrillator.

  9. Interaction between shock coils increased the incidence of inappropriate therapies and lead failure in implantable cardioverter defibrillator.

    Science.gov (United States)

    El Garhy, Mohammad; Ohlow, Marc-Alexander; Lauer, Bernward

    Shock coil interaction in patients with multiple implantable cardioverter defibrillator (ICD) leads is occasionally observed. We aimed to evaluate the incidence of shock coil interaction and its clinical relevance. All ICD patients (646 patients) who came to follow up control in our ICD ambulance between January 1, 2011, and December 31, 2011 in the department of cardiology in Bad Berka hospital were retrospectively evaluated in this study. All baseline demographic, clinical, and procedural characteristics and postoperative chest x ray in postero-anterior and lateral view as well as clinical and ICD follow up data were evaluated. Among 646 patients 42 had multiple ICD leads (6.5%) of whom 36 patients (5.5% of total cohort patients and 85.7% of patients with multiple ICD leads) had shock coil interaction and presented the study group (Group I). The control group (Group II) consisted of 610 patients without coil-coil interaction including patients with single shock lead (604 patients) or patients with multiple leads but without interaction between shock coils (6 patients). Inappropriate anti-tachycardia therapies and RV lead revisions were more frequent in patients with interaction between shock coils (Group I vs Group II: 27.7% and 5.7%; p = 0.049 and 30.6% vs 6.4; p = 0.0001, respectively). Interaction between shock coils may be one of possible causes of lead failure and resulted in inappropriate therapies and subsequent lead revision. Copyright © 2018 Indian Heart Rhythm Society. Production and hosting by Elsevier B.V. All rights reserved.

  10. Failed anti-tachycardia pacing can be used to differentiate atrial arrhythmias from ventricular tachycardia in implantable cardioverter-defibrillators.

    Science.gov (United States)

    Michael, Kevin A; Enriquez, Andres; Baranchuk, Adrian; Haley, Charlotte; Caldwell, Jane; Simpson, Christopher S; Abdollah, Hoshiar; Redfearn, Damian P

    2015-01-01

    Atrial fibrillation/tachycardia (AF/AT) may result in inappropriate therapies in implantable cardioverter-defibrillators (ICDs). The post-pacing interval (PPI) and tachycardia cycle length difference (PPI - TCL) has been previously demonstrated to indicate the proximity of the pacing site to a tachycardia origin. We postulated that the PPI and PPI - TCL would be greater in AT/AF vs. ventricular tachycardia (VT) after episodes of failed anti-tachycardia pacing (ATP). This was a single-centre, retrospective study evaluating consecutive patients implanted with dual (DR)/biventricular (BIV) ICDs. Stored electrograms were used to determine whether the ATP captured the arrhythmia and the arrhythmia did not present with primary or secondary termination. Measurements were done using manual calipers. A total of 155 patients were included. There were 79 BIV and 76 DR devices. In total, 39 episodes were identified in 20 patients over a 23-month follow-up period. A total of 76 sequences of ATP (burst/ramp) were delivered, 28 (37%) of them inappropriate. Fifty-one events (18 AT/AF and 33 VT) were compared. The mean PPI was 693 ± 96 vs. 512 ± 88 ms (P failed ATP differs significantly between AF/AT and VT and are therefore useful indices to discriminate between supraventricular tachycardia and VT in ICDs. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  11. Association of air pollution with increased incidence of ventricular tachyarrhythmias recorded by implantable cardioverter defibrillators: Vulnerable patients to air pollution.

    Science.gov (United States)

    Kim, In-Soo; Sohn, Jungwoo; Lee, Seung-Jun; Park, Jin-Kyu; Uhm, Jae-Sun; Pak, Hui-Nam; Lee, Moon-Hyoung; Kim, Changsoo; Joung, Boyoung

    2017-08-01

    This study investigated the acute effects of exposure to air pollution on ventricular tachyarrhythmias (VTAs) in an East Asian population. The association between air pollution and VTA has not yet been studied in an East Asian country affected by the Asian dust phenomenon, which worsens air quality. The study cohort consisted of 160patients with implantable cardioverter defibrillator (ICD) devices in the Seoul metropolitan area who were followed for 5.5±3.8years. We used ICD records of VTAs and matched these with hourly measurements of air pollutant concentrations and meteorological data. Fine particle mass and gaseous air pollution plus temperature and relative humidity were measured hourly during the study period. During the study period, 1064 VTA events including 204 instances of ventricular fibrillation (VF) were observed. We found a statistically significant association between overall VTA events and SO 2 (lag 24h; OR 1.49, 95%CI 1.16-1.92, p=0.002), PM 10 (lag 2h; OR 2.56, 95%CI 2.03-3.23, pair pollution and VTA were observed in a metropolitan area of an East Asian country. Exposures to SO 2 , PM 10 , NO 2 , and CO were significantly associated with VTAs in ICD patients with SHD. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Outcomes after asystole events occurring during wearable defibrillator-cardioverter use.

    Science.gov (United States)

    Liang, Jackson J; Bianco, Nicole R; Muser, Daniele; Enriquez, Andres; Santangeli, Pasquale; D'Souza, Benjamin A

    2018-04-26

    To examine whether wearable cardioverter defibrillator (WCD) alarms for asystole improve patient outcomes and survival. All asystole episodes recorded by the WCD in 2013 were retrospectively analyzed from a database of device and medical record documentation and customer call reports. Events were classified as asystole episodes if initial presenting arrhythmia was asystole (< 10 beats/minor ≥ 5 s pause). Survival was defined as recovery at the scene or arrival to a medical facility alive, or not requiring immediate medical attention. Episodes occurring in hospitals, nursing homes, or ambulances were considered to be under medical care. Serious asystole episodes were defined as resulting in unconsciousness, hospital transfer, or death. Of the total 51933 patients having worn the WCD in 2013, there were 257 patients (0.5%) who had asystole episodes and comprised the study cohort. Among the 257 patients (74% male, median age 69 years), there were 264 asystole episodes. Overall patient survival was 42%. Most asystoles were considered "serious" ( n = 201 in 201 patients, 76%), with a 26% survival rate. All 56 patients with "non-serious" asystole episodes survived. Being under medical care was associated with worse survival of serious asystoles. Among acute survivors, 20% later died during WCD use (a median 4 days post asystole episode). Of the 86 living patients at the end of WCD use period, 48 (56%) received ICD/pacemaker and 17 (20%) improved their condition. Survival rates after asystole in patients with WCD are higher than historically reported survival rates. Those under medical care at time of asystole exhibited lower survival.

  13. Web-Based Distress Management for Implantable Cardioverter Defibrillator Patients

    DEFF Research Database (Denmark)

    Habibović, Mirela; Denollet, Johan; Cuijpers, Pim

    2017-01-01

    distress post-ICD implantation. The WEB-based distress management program for ICD patients (WEBCARE) was developed to mitigate anxiety and depression and enhance health-related quality of life in ICD patients. This study investigates the 6- and 12-months outcomes. METHOD: A total of 289 consecutive ICD...... care as usual. RESULTS: Current findings show no significant difference on anxiety, depression or quality of life between the WEBCARE and Usual Care group at 6- and 12-months postimplantation. CONCLUSIONS: In this clinical trial of a Web-based behavioral intervention for ICD patients, the Web...

  14. Psychological intervention following implantation of an implantable defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van den Broek, Krista C; Sears, Samuel F

    2007-01-01

    The medical benefits of the implantable cardioverter defibrillator (ICD) are unequivocal, but a subgroup of patients experiences emotional difficulties following implantation. For this subgroup, some form of psychological intervention may be warranted. This review provides an overview of current ...

  15. [Impact of metoprolol use in the treatment of patients with electrical-storm after cardioverter defibrillators implantation].

    Science.gov (United States)

    Yu, Jin-bo; Yang, Bing; Xu, Dong-jie; Chen, Ming-long; Shan, Qi-jun; Zou, Jian-gang; Chen, Chun; Zhang, Feng-xiang; Hou, Xiao-feng; Li, Wen-qi; Zhang, Rong; Cao, Ke-jiang

    2011-08-01

    To explore the effectiveness of the metoprolol dosage adjustment on reducing the incidence of electrical-storm (ES) in patients with Implantable Cardioverter Defibrillators (ICDs). Data from patients with ICD implantation between Jan, 2003 and Jun, 2006 in our hospital were retrospectively analyzed. ES was defined as either ≥ 3 times of ventricular tachyarrhythmias (VTAs) resulting in ICD therapy or VTAs lasting more than 30 s detected by ICD without any therapy within 24 hours. During a follow-up period of (27.5 ± 21.2) months, ES was recorded in 39 cases [34 males, average age (52.0 ± 13.1) years] out of 119 patients (32.8%) and 9 patients died after ES. During the period of storm attack, ES was successfully controlled in 25/30 patients by various interventions, including predisposing factors corrected in 5 cases, ICD reprogramming and antiarrhythmic drugs therapy optimized in 16 cases (one received intravenous injection of metoprolol), and VTAs eliminated by catheter ablation in 4 cases. ES was spontaneously resolved in the remaining 5 cases. In the chronic phase, 2 patients with Brugada syndrome were treated with Quinidine mono-therapy while the dosage of metoprolol was adjusted in the remaining 23 patients and the dosage of metoprolol was increased gradually from (26.8 ± 13.9) mg/d to (88.9 ± 53.5) mg/d without any adverse effects (9 patients received also oral amiodarone 200 mg/d). Post dosage adjustment, the total VTA episodes [(1.9 ± 1.7) times/month vs. (0.8 ± 0.6) times/month, P = 0.004], incidence of antitachycardia pacing therapies [(4.2 ± 3.8) runs/month vs. (2.3 ± 2.0) runs/month, P = 0.003], as well as electrical cardioversion or defibrillation [(1.1 ± 0.9) times/month vs. (0.4 ± 0.2) times/month, P = 0.001] were significantly decreased. ES was not controlled until a extremely high dosage [225 - 300 (255.3 ± 41.7) mg/d] of metoprolol was reached in the remaining 5 patients. Metoprolol use is essential and its dosage should be

  16. Automatic remote monitoring utilizing daily transmissions: transmission reliability and implantable cardioverter defibrillator battery longevity in the TRUST trial.

    Science.gov (United States)

    Varma, Niraj; Love, Charles J; Schweikert, Robert; Moll, Philip; Michalski, Justin; Epstein, Andrew E

    2018-04-01

    Benefits of automatic remote home monitoring (HM) among implantable cardioverter defibrillator (ICD) patients may require high transmission frequency. However, transmission reliability and effects on battery longevity remain uncertain. We hypothesized that HM would have high transmission success permitting punctual guideline based follow-up, and improve battery longevity. This was tested in the prospective randomized TRUST trial. Implantable cardioverter defibrillator patients were randomized post-implant 2:1 to HM (n = 908) (transmit daily) or to Conventional in-person monitoring [conventional management (CM), n = 431 (HM disabled)]. In both groups, five evaluations were scheduled every 3 months for 15 months. Home Monitoring technology performance was assessed by transmissions received vs. total possible, and number of scheduled HM checks failing because of missed transmissions. Battery longevity was compared in HM vs. CM at 15 months, and again in HM 3 years post-implant using continuously transmitted data. Transmission success per patient was 91% (median follow-up of 434 days). Overall, daily HM transmissions were received in 315 795 of a potential 363 450 days (87%). Only 55/3759 (1.46%) of unsuccessful scheduled evaluations in HM were attributed to transmission loss. Shock frequency and pacing percentage were similar in HM vs. CM. Fifteen month battery longevity was 12% greater in HM (93.2 ± 8.8% vs. 83.5 ± 6.0% CM, P battery longevity was 50.9 ± 9.1% (median 52%) at 36 months. Automatic remote HM demonstrated robust transmission reliability. Daily transmission load may be sustained without reducing battery longevity. Home Monitoring conserves battery longevity and tracks long term device performance. ClinicalTrials.gov; NCT00336284.

  17. Defibrillator implantations for primary prevention in the United States: Inappropriate care or inadequate documentation: Insights from the National Cardiovascular Data ICD Registry.

    Science.gov (United States)

    Kaiser, Daniel W; Tsai, Vivian; Heidenreich, Paul A; Goldstein, Mary K; Wang, Yongfei; Curtis, Jeptha; Turakhia, Mintu P

    2015-10-01

    Prior studies have reported that more than 20% of implantable cardioverter-defibrillator (ICD) implantations in the United States do not adhere to trial-based criteria. We sought to investigate the patient characteristics associated with not meeting the inclusion criteria of the clinical trials that have demonstrated the efficacy of primary prevention ICDs. Using data from the National Cardiovascular Data Registry's ICD Registry, we identified patients who received ICDs for primary prevention from January 2006 to December 2008. We determined whether patients met the inclusion criteria of at least 1 of the 4 ICD primary prevention trials: Multicenter Automatic Defibrillator Implantation Trial (MADIT), MADIT-II, Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT), and the Multicenter Unsustained Tachycardia Trial (MUSTT). Among 150,264 patients, 86% met criteria for an ICD implantation based on trial data. The proportion of patients who did not meet trial-based criteria increased as age decreased. In multivariate analysis, the significant predictors for not meeting trial criteria included prior cardiac transplantation (odds ratio [OR] 2.1), pediatric electrophysiology operator (OR 2.0), and high-grade atrioventricular conduction disease (OR 1.4). Among National Cardiovascular Data Registry registrants receiving first-time ICDs for primary prevention, the majority met trial-based criteria. Multivariate analyses suggested that many patients who did not meet the trial-based criteria may have had clinical circumstances that warranted ICD implantation. These findings caution against the use of trial-based indications to determine site quality metrics that could penalize sites that care for younger patients. The planned incorporation of appropriate use criteria into the ICD registry may better characterize patient- and site-level quality and performance. Published by Elsevier Inc.

  18. Implantable defibrillator therapy: more than defibrillation...

    NARCIS (Netherlands)

    D.A.M.J. Theuns (Dominic)

    2005-01-01

    textabstractDuring the past 25 years, the implantable cardioverter-defibrillator (ICD) has evolved from the treatment of last resort to the gold standard for patients at high risk for life­threatening ventricular tachyarrhythmias. Patients at high risk include those who survived life-threatening

  19. Does ICD indication affect quality of life and levels of distress?

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Sears, Samuel F; Burg, Matthew M

    2009-01-01

    The implantable cardioverter defibrillator (ICD) is the treatment of choice for life-threatening arrhythmias, with ICD indications having recently been extended to include primary prophylaxis. Despite the medical benefits of the ICD, there is an ongoing debate as to the impact of the ICD on patie...

  20. Impact of Moderate to Severe Renal Impairment on Mortality and Appropriate Shocks in Patients with Implantable Cardioverter Defibrillators

    Directory of Open Access Journals (Sweden)

    Venkata M. Alla

    2010-01-01

    Full Text Available Background. Due to underrepresentation of patients with chronic kidney disease (CKD in large Implantable-Cardioverter Defibrillator (ICD clinical trials, the impact of ICD remains uncertain in this population. Methods. Consecutive patients who received ICD at Creighton university medical center between years 2000–2004 were included in a retrospective cohort after excluding those on maintenance dialysis. Based on baseline Glomerular filtration rate (GFR, patients were classified as severe CKD: GFR < 30 mL/min; moderate CKD: GFR: 30–59 mL/min; and mild or no CKD: GFR ≥ 60 mL/min. The impact of GFR on appropriate shocks and survival was assessed using Kaplan-Meier method and Generalized Linear Models (GLM with log-link function. Results. There were 509 patients with a mean follow-up of 3.0 + 1.3 years. Mortality risk was inversely proportional to the estimated GFR: 2 fold higher risk with GFR between 30–59 mL/min and 5 fold higher risk with GFR < 30 mL/min. One hundred and seventy-seven patients received appropriate shock(s; appropriate shock-free survival was lower in patients with severe CKD (GFR < 30 compared to mild or no CKD group (2.8 versus 4.2 yrs. Conclusion. Even moderate renal dysfunction increases all cause mortality in CKD patients with ICD. Severe but not moderate CKD is an independent predictor for time to first appropriate shock.

  1. [Nurses and doctors in the management of arrhytmic complications: the case of electric storm in patients with an implantable cardioverter defibrillator].

    Science.gov (United States)

    Plebani, Laura; Occhetta, Eraldo

    2006-01-01

    The evolution of arrhythmologic technology introduced new therapeutic opportunities for cardiology patients. Competence, continuity of care, integration and collaboration between medical doctors and nurses allow a safe management of short and long term complications. A typical example of a new arrhythmic complication is the "electrical storm" or "arrhythmic warm up" in patients implanted with a cardioverter-defibrillator (ICD). The definition and epidemiology of the electrical storm stress the relevance of this clinical situation; its dramatic emergency involves several aspects of nursing care, clinical, prognostic, ethical and deontological. The definition and implementation of an integrated protocol for the treatment of this condition is described and ethical and unresolved questions are rised. One of these problems is the recommendation to offer the patient the opportunity to receive information about the option of inactivating the ICD.

  2. Sex and Race/Ethnicity Differences in Implantable Cardioverter-Defibrillator Counseling and Use Among Patients Hospitalized With Heart Failure: Findings from the Get With The Guidelines-Heart Failure Program.

    Science.gov (United States)

    Hess, Paul L; Hernandez, Adrian F; Bhatt, Deepak L; Hellkamp, Anne S; Yancy, Clyde W; Schwamm, Lee H; Peterson, Eric D; Schulte, Phillip J; Fonarow, Gregg C; Al-Khatib, Sana M

    2016-08-16

    Previous studies have found that women and black patients eligible for a primary prevention implantable cardioverter-defibrillator (ICD) are less likely than men or white patients to receive one. We performed an observational analysis of the Get With The Guidelines-Heart Failure Program from January 1, 2011, to March 21, 2014. Patients admitted with heart failure and an ejection fraction ≤35% without an ICD were included. Rates of ICD counseling among eligible patients and ICD receipt among counseled patients were examined by sex and race/ethnicity. Among 21 059 patients from 236 sites, 4755 (22.6%) received predischarge ICD counseling. Women were counseled less frequently than men (19.3% versus 24.6%, Prace/ethnic group 14.4% versus white 24.3%, Pdifferences by race and ethnicity persisted. © 2016 American Heart Association, Inc.

  3. How to Respond to an Implantable Cardioverter-Defibrillator Recall

    Science.gov (United States)

    ... managing your emotions appropriately and being proactive. Behavioral Management Plan Your best plan of action is to ... recall for all patients. The recall of 1 brand of ICD does not mean that there is ...

  4. Beam Profile Disturbances from Implantable Pacemakers or Implantable Cardioverter-Defibrillator Interactions

    Energy Technology Data Exchange (ETDEWEB)

    Gossman, Michael S., E-mail: mgossman@tsrcc.com [Tri-State Regional Cancer Center, Medical Physics Section, Ashland, KY (United States); Comprehensive Heart and Vascular Associates, Heart and Vascular Center, Ashland, KY (United States); Medtronic, Inc., External Research Program, Mounds View, MN (United States); Nagra, Bipinpreet; Graves-Calhoun, Alison; Wilkinson, Jeffrey [Tri-State Regional Cancer Center, Medical Physics Section, Ashland, KY (United States); Comprehensive Heart and Vascular Associates, Heart and Vascular Center, Ashland, KY (United States); Medtronic, Inc., External Research Program, Mounds View, MN (United States)

    2011-01-01

    The medical community is advocating for progressive improvement in the design of implantable cardioverter-defibrillators and implantable pacemakers to accommodate elevations in dose limitation criteria. With advancement already made for magnetic resonance imaging compatibility in some, a greater need is present to inform the radiation oncologist and medical physicist regarding treatment planning beam profile changes when such devices are in the field of a therapeutic radiation beam. Treatment plan modeling was conducted to simulate effects induced by Medtronic, Inc.-manufactured devices on therapeutic radiation beams. As a continuation of grant-supported research, we show that radial and transverse open beam profiles of a medical accelerator were altered when compared with profiles resulting when implantable pacemakers and cardioverter-defibrillators are placed directly in the beam. Results are markedly different between the 2 devices in the axial plane and the sagittal planes. Vast differences are also presented for the therapeutic beams at 6-MV and 18-MV x-ray energies. Maximum changes in percentage depth dose are observed for the implantable cardioverter-defibrillator as 9.3% at 6 MV and 10.1% at 18 MV, with worst distance to agreement of isodose lines at 2.3 cm and 1.3 cm, respectively. For the implantable pacemaker, the maximum changes in percentage depth dose were observed as 10.7% at 6 MV and 6.9% at 18 MV, with worst distance to agreement of isodose lines at 2.5 cm and 1.9 cm, respectively. No differences were discernible for the defibrillation leads and the pacing lead.

  5. [Full dental rehabilitation of a patient with implantable cardioverter defibrillator].

    Science.gov (United States)

    Imre, Ildikó; Tóth, Zsuzsanna

    2012-06-01

    During dental rehabilitation of a patient with ICD, an upper telescope retained overdenture with acrylic baseplate and lower cantilever bridges were constructed. In the consultation following the anamnesis and the clinical examination, the cardiologist did not believe antibiotic profilaxis to be necessary, adding that it is advisable to avoid the use of ultrasonic depurator and electrocauter. Nowadays after saving the life the improving of patient's better quality of life is an important aspect. The risk of ICD-implantation is minimal however, not negligible, the patient can pursue a way of life free of limitation. According to the latest trends, the number of ICD-implantations will increase exponentially in the near future, due to the aging of the population, the simplification and safeness of implantation and the increase of patients who can be treated with the device. In case of arritmia or putative dysfunction, the latest ICD-s are able to send emergency alert to the arritmia centre with the help of an outer transmitter. Probably the system will completely change the follow-up of patients with ICD within the next few years, clinical researches of its efficiency are going on at present.

  6. Effect of defibrillation threshold testing on effectiveness of the subcutaneous implantable cardioverter defibrillator.

    Science.gov (United States)

    Peddareddy, Lakshmi; Merchant, Faisal M; Leon, Angel R; Smith, Paige; Patel, Akshar; El-Chami, Mikhael F

    2018-06-12

    Defibrillation threshold (DFT) testing is recommended with the subcutaneous ICD (SICD). To describe first shock efficacy for appropriate SICD therapies stratified by the presence of implant DFT testing. We reviewed all patients receiving SICDs at our institution and stratified them based on whether implant DFT testing was performed. Appropriate shocks were reviewed to see if ventricular tachycardia/ventricular fibrillation (VT/VF) terminated with a single shock. First shock efficacy was stratified by implant DFT status. 178 patients implanted with SICDs and followed in our center were included in this study. Of these, 135 (76 %) underwent DFT testing (DFT (+) group). In the DFT (+) 80 appropriate shocks were needed to treat 69 episodes of VT/VF. The first shock was effective in 61 out of 69 episodes (88.4 %), whereas multiple shocks were required to terminate VT/VF in the remaining 8 episodes. Among 43 patients without implant DFT testing (DFT (-) group), 20 appropriate shocks to treat 17 episodes of VT/VF occurred in 7 patients. VT/VF was successfully terminated with the first shock in 16 out of 17 episodes (first shock efficacy 94.1 %). There was no significant difference in first shock effectiveness between those with and without implant DFT testing (p = 0.97). A strategy that omits DFT testing at implant did not appear to compromise the effictiveness of the SICD. These data suggest that routine DFT testing at SICD implant might not be necessary. Randomized trials are needed to confirm this finding. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  7. Device orientation of a leadless pacemaker and subcutaneous implantable cardioverter-defibrillator in canine and human subjects and the effect on intrabody communication.

    Science.gov (United States)

    Quast, Anne-Floor B E; Tjong, Fleur V Y; Koop, Brendan E; Wilde, Arthur A M; Knops, Reinoud E; Burke, Martin C

    2018-02-14

    The development of communicating modular cardiac rhythm management systems relies on effective intrabody communication between a subcutaneous implantable cardioverter-defibrillator (S-ICD) and a leadless pacemaker (LP), using conducted communication. Communication success is affected by the LP and S-ICD orientation. This study is designed to evaluate the orientation of the LP and S-ICD in canine subjects and measure success and threshold of intrabody communication. To gain more human insights, we will explore device orientation in LP and S-ICD patients. Canine subjects implanted with a prototype S-ICD and LP (both Boston Scientific, MA, USA) with anterior-posterior fluoroscopy images were included in this analysis. For comparison, a retrospective analysis of human S-ICD and LP patients was performed. The angle of the long axis of the LP towards the vertical axis of 0°, and distance between the coil and LP were measured. Twenty-three canine subjects were analysed. Median angle of the LP was 29° and median distance of the S-ICD coil to LP was 0.8 cm. All canine subjects had successful communication. The median communicating threshold was 2.5 V. In the human retrospective analysis, 72 LP patients and 100 S-ICD patients were included. The mean angle of the LP was 56° and the median distance between the S-ICD coil and LP was 4.6 cm. Despite the less favourable LP orientation in canine subjects, all communication attempts were successful. In the human subjects, we observed a greater and in theory more favourable LP angle towards the communication vector. These data suggests suitability of human anatomy for conductive intrabody communication.

  8. Implantable cardioverter defibrillator does not cure the heart.

    Science.gov (United States)

    Sławuta, Agnieszka; Boczar, Krzysztof; Ząbek, Andrzej; Gajek, Jacek; Lelakowski, Jacek; Vijayaraman, Pugazhendhi; Małecka, Barbara

    2018-01-23

    A man with non-ischemic cardiomyopathy, EF 22%, permanent AF and ICD was admitted for elective device replacement. The need for the optimization of the ventricular rate and avoidance of right ventricular pacing made it necessary to up-grade the existing pacing system using direct His bundle pacing and dual chamber ICD. This enabled the regularization of ventricular rate, avoiding the RV pacing and optimize the beta-blocker dose. The one month follow-up already showed reduction in left ventricle diameter, improvement in ejection fraction, NYHA class decrease to II. The His bundle pacing enabled the optimal treatment of the patient resulting in excellent clinical improvement.

  9. Safety of implantable pacemakers and cardioverter defibrillators in the magnetic field of a novel remote magnetic navigation system.

    Science.gov (United States)

    Jilek, Clemens; Tzeis, Stylianos; Reents, Tilko; Estner, Heidi-Luise; Fichtner, Stephanie; Ammar, Sonia; Wu, Jinjin; Hessling, Gabriele; Deisenhofer, Isabel; Kolb, Christof

    2010-10-01

    Electromagnetic interference with pacemaker and implantable cardioverter defibrillator (ICD) systems may cause temporary or permanent system malfunction of implanted devices. The aim of this study was to evaluate potential interference of a novel magnetic navigation system with implantable rhythm devices. A total of 121 devices (77 pacemakers, 44 ICDs) were exposed to an activated NIOBE II® Magnetic Navigation System (Stereotaxis, St. Louis, MO, USA) at the maximal magnetic field strength of 0.1 Tesla and evaluated in vitro with respect to changes in parameter settings of the device, changes of the battery status/detection of elective replacement indication, or alterations of data stored in the device. A total of 115 out of 121 (95%) devices were free of changes in parameter settings, battery status, and internally stored data after repeated exposition to the electromagnetic field of the remote magnetic navigation system. Interference with the magnetic navigation field was observed in 6 pacemakers, resulting in reprogramming to a power-on-reset mode with or without detection of the elective replacement indication in 5 devices and abnormal variance of battery status in one device. All pacemakers could be reprogrammed to the initial modes and the battery status proved to be normal some minutes after the pacemakers had been removed from the magnetic field. Interference of a remote magnetic navigation system (at maximal field strength) with pacemakers and ICDs not connected to leads with antitachycardic detection and therapies turned off is rare. Occurring functional abnormalities could be reprogrammed in our sample. An in vitro study will give information about interference of devices connected to leads. © 2010 Wiley Periodicals, Inc.

  10. A clinical example of extreme dose exposure for an implanted cardioverter-defibrillator. Beyond the DEGRO guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Hristova, Yoana; Koehn, Janett; Preuss, Stefanie [Johann Wolfgang Goethe University Frankfurt, Department of Radiation Oncology, University Hospital, Frankfurt (Germany); Roedel, Claus; Balermpas, Panagiotis [Johann Wolfgang Goethe University Frankfurt, Department of Radiation Oncology, University Hospital, Frankfurt (Germany); German Cancer Research Center (DKFZ), Heidelberg (Germany); German Cancer Consortium (DKTK), Frankfurt am Main (Germany)

    2017-09-15

    Considering that the number of malignant diseases in patients over 65 years of age is increasing, it often occurs that patients who carry a cardiac implanted electronic device must undergo radiotherapy. Ionizing radiation can disturb the function of the implantable cardioverter-defibrillator (ICD). As a result of this, an update of the DEGRO/DKG guidelines for radiotherapy of this patient group has been published. We report the case of a patient with an ICD and T-lymphoblastic lymphoma with cardiac involvement, who received i.a. a total body irradiation with 8 Gy followed by a consolidating radiotherapy of the pericardium with 14 Gy as well as additional radiotherapy courses after consecutive recurrences. For the purposes of the treatment, the antitachyarrhythmia (ATA) therapy was deactivated and temporarily replaced through a life vest. According to the current DEGRO guidelines for irradiation of patients with cardiac implanted electronic devices, a categorization of the patient in the ''high-risk'' group was made. Furthermore, regular telemetric checks of the ICD device were performed before and after treatment. Despite unavailable declaration of the manufacturer regarding the cumulative tolerable dose and DEGRO recommendation for a cumulative dose <2 Gy, the aftercare was unproblematic and normal values were assessed for all relevant ICD parameters, despite a cumulative dose >10 Gy in the device. This case shows that if the cardiac implanted electronic devices are not directly irradiated und the energy used is reduced to 6 MV, irradiation-induced damage is less likely and can possibly be prevented. (orig.) [German] Vor dem Hintergrund der steigenden Zahl von Krebserkrankungen bei Patienten ueber 65 Jahren kommt es haeufig vor, dass sich Patienten mit einem kardialen implantierten elektronischen Geraet einer Strahlentherapie unterziehen muessen. Ionisierende Strahlung kann die Funktion des implantierbaren Kardioverter-Defibrillators (ICD

  11. Shock whilst gardening--implantable defibrillators & lawn mowers.

    Science.gov (United States)

    Von Olshausen, G; Lennerz, C; Grebmer, C; Pavaci, H; Kolb, C

    2014-02-01

    Electromagnetic interference with implantable cardioverter defibrillators (ICDs) can cause inappropriate shock delivery or temporary inhibition of ICD functions. We present a case of electromagnetic interference between a lawn mower and an ICD resulting in an inappropriate discharge of the device due to erroneous detection of ventricular fibrillation.

  12. Effect of psycho-educational interventions on quality of life in patients with implantable cardioverter defibrillators: a meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Kao, Chi-Wen; Chen, Miao-Yi; Chen, Ting-Yu; Lin, Pai-Hui

    2016-09-30

    Implantable cardioverter defibrillators (ICD) were developed for primary and secondary prevention of sudden cardiac death. However, ICD recipients' mortality is significantly predicted by their quality of life (QOL). The aim of this meta-analysis was to evaluate the effects of psycho-educational interventions on QOL in patients with ICDs. We systematically searched PubMed, Medline, Cochrane Library, and CINAHL through April 2015 and references of relevant articles. Studies were reviewed if they met following criteria: (1) randomized controlled trial, (2) participants were adults with an ICD, and (3) data were sufficient to evaluate the effect of psychological or educational interventions on QOL measured by the SF-36 or SF-12. Studies were independently selected and their data were extracted by two reviewers. Study quality was evaluated using a modified Jadad scale. The meta-analysis was conducted using the Cochrane Collaboration's Review Manager Software Package (RevMan 5). Study heterogeneity was assessed by Q statistics and I 2 statistic. Depending on heterogeneity, data were pooled across trials using fixed-effect or random-effect modeling. Seven randomized controlled trials fulfilled the inclusion and exclusion criteria, and included 1017 participants. The psycho-educational interventions improved physical component summary (PCS) scores in the intervention groups more than in control groups (mean difference 2.08, 95 % CI 0.86 to 3.29, p educational interventions improved the physical component, but not the mental component of QOL in patients with ICDs.

  13. The oral cavity is not a primary source for implantable pacemaker or cardioverter defibrillator infections

    Science.gov (United States)

    2013-01-01

    Background To test the hypothesis that the oral cavity is a potential source for implantable pacemaker and cardioverter defibrillators infections, the bacterial diversity on explanted rhythm heart management devices was investigated and compared to the oral microbiome. Methods A metagenomic approach was used to analyze the bacterial diversity on the surfaces of non-infected and infected pacemakers. The DNA from surfaces swaps of 24 non-infected and 23 infected pacemaker were isolated and subjected to bacterial-specific DNA amplification, single strand conformation polymorphism- (SSCP) and sequencing analysis. Species-specific primer sets were used to analyze for any correlation between bacterial diversity on pacemakers and in the oral cavity. Results DNA of bacterial origin was detected in 21 cases on infected pacemakers and assigned to the bacterial phylotypes Staphylococcus epidermidis, Propionibacterium acnes, Staphylococcus aureus, Staphylococcus schleiferi and Stapyhlococcus. In 17 cases bacterial DNA was found on pacemakers with no clinical signs of infections. On the basis of the obtained sequence data, the phylotypes Propionibacterium acnes, Staphylococcus and an uncultured bacterium were identified. Propionibacterium acnes and Staphylococcus epidermidis were the only bacteria detected in pacemeaker (n = 25) and oral samples (n = 11). Conclusions The frequency of the coincidental detection of bacteria on infected devices and in the oral cavity is low and the detected bacteria are highly abundant colonizers of non-oral human niches. The transmission of oral bacteria to the lead or device of implantable pacemaker or cardioverter defibrillators is unlikely relevant for the pathogenesis of pacemaker or cardioverter defibrillators infections. PMID:23575037

  14. Current state of knowledge and experts' perspective on the subcutaneous implantable cardioverter-defibrillator.

    Science.gov (United States)

    Santini, Massimo; Cappato, Riccardo; Andresen, Dietrich; Brachmann, Johannes; Davies, D Wyn; Cleland, John; Filippi, Alessandro; Gronda, Edoardo; Hauer, Richard; Steinbeck, Gerhard; Steinhaus, David

    2009-06-01

    ICD implantation is today a well-recognized therapy to prevent sudden cardiac death. The available implantable devices at present need the use of permanent endocavitary leads which may cause, in some instances, serious troubles to the patients (lead dislodgement, ventricular perforation, lead infections, etc.). A new implantable defibrillator provided by only a subcutaneous lead is at present under evaluation. Its potential indications, usefulness benefits, and problems represent an interesting field of investigation and discussion. This paper describes the conclusions recently reached by a panel of experts, with regard to the potential role of an implantable subcutaneous defibrillator in the prevention of sudden cardiac death.

  15. Identifying patients with less potential to benefit from implantable cardioverter-defibrillator therapy: comparison of the performance of four risk scoring systems.

    Science.gov (United States)

    Kaura, Amit; Sunderland, Nicholas; Kamdar, Ravi; Petzer, Edward; McDonagh, Theresa; Murgatroyd, Francis; Dhillon, Para; Scott, Paul

    2017-08-01

    Patients at high non-sudden cardiac death risk may gain no significant benefit from implantable cardioverter-defibrillator (ICD) therapy. A number of approaches have been proposed to identify these patients, including single clinical markers and more complex scoring systems. The aims of this study were to use the proposed scoring systems to (1) establish how many current ICD recipients may be too high risk to derive significant benefit from ICD therapy and (2) evaluate how well the scoring systems predict short-term mortality in an unselected ICD cohort. We performed a single-centre retrospective observational study of all new ICD implants over 5 years (2009-2013). We used four published scoring systems (Bilchick, Goldenberg, Kramer and Parkash) and serum urea to identify new ICD recipients whose short-term predicted mortality risk was high. We evaluated how well the scoring systems predicted death. Over 5 years, there were 406 new implants (79% male, mean age 70 (60-76), 58% primary prevention). During a follow-up of 936 ± 560 days, 96 patients died. Using the scoring systems, the proportion of ICD recipients predicted to be at high short-term mortality risk were 5.9% (Bilchick), 34.7% (Goldenberg), 7.4% (Kramer), 21.4% (Parkash) and 25% (urea, cut-off of >9.28 mM). All four risk scores predicted mortality (P systems, a significant proportion of current ICD recipients are at high short-term mortality risk. Although all four scoring systems predicted mortality during follow-up, none significantly outperformed serum urea.

  16. Intensity of primary emotions in patients after implantation of an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Stoier, Louise; Pedersen, Preben Ulrich; Berg, Selina Kikkenborg

    2013-01-01

    Background: Experienced emotions can affect the outcome of, and adherence to a cardiac rehabilitation program, and patients coping with an illness. With more awareness of the expressed emotions, health professionals might be better able to understand the reactions of patients and to improve...... the support needed for coping. Living with an Implantable Cardi- overter Defibrillator can lead to anxiety and depression. Focus on the intensity of the primary emotions might be a potential to prevent development of these psychological states. Objectives: The aim of this paper are 1) to describe...... the intensity of primary emotions in patients after implantation of an Implantable Cardioverter Defibrillator and 2) to compare them with both the intensity of primary emotions in patients with a recent Myocardial Infarction and with a healthy population. Method: The intensity of primary emotions in patients...

  17. Tricuspid Valve Dysfunction Following Pacemaker or Cardioverter-Defibrillator Implantation.

    Science.gov (United States)

    Chang, James D; Manning, Warren J; Ebrille, Elisa; Zimetbaum, Peter J

    2017-05-09

    The potential for cardiac implantable electronic device leads to interfere with tricuspid valve (TV) function has gained increasing recognition as having hemodynamic and clinical consequences associated with incremental morbidity and death. The diagnosis and treatment of lead-related (as distinct from functional) tricuspid regurgitation pose unique challenges. Because of pitfalls in routine diagnostic imaging, a high level of clinical suspicion must be maintained to avoid overlooking the possibility that worsening heart failure is a consequence of mechanical interference with TV leaflet mobility or coaptation and is amenable to lead extraction or valve repair or replacement. The future of cardiac implantable electronic devices includes pacing and perhaps defibrillation without a lead traversing the TV. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  18. Cost-Effectiveness of Adding Cardiac Resynchronization Therapy to an Implantable Cardioverter-Defibrillator Among Patients With Mild Heart Failure

    DEFF Research Database (Denmark)

    Woo, Christopher Y; Strandberg, Erika J; Schmiegelow, Michelle D

    2015-01-01

    -defibrillator (ICD) alone among patients with left ventricular systolic dysfunction, prolonged intraventricular conduction, and mild heart failure. DESIGN: Markov decision model. DATA SOURCES: Clinical trials, clinical registries, claims data from Centers for Medicare & Medicaid Services, and Centers for Disease...

  19. Nurse- and peer-led self-management programme for patients with an implantable cardioverter defibrillator; a feasibility study

    Directory of Open Access Journals (Sweden)

    van Eijk Jacques

    2007-09-01

    Full Text Available Abstract Background The prevalence of cardiovascular disease is increasing. Improved treatment options increase survival after an acute myocardial infarction or sudden cardiac arrest, although patients often have difficulty adjusting and regaining control in daily life. In particular, patients who received an implantable cardioverter defibrillator (ICD experience physical and psychological problems. Interventions to enhance perceived control and acceptance of the device are therefore necessary. This paper describes a small-scale study to explore the feasibility and the possible benefits of a structured nurse- and peer-led self-management programme ('Chronic Disease Self-Management Program' – CDSMP among ICD patients. Methods Ten male ICD patients (mean age = 65.5 years participated in a group programme, consisting of six sessions, led by a team consisting of a nurse specialist and a patient with cardiovascular disease. Programme feasibility was evaluated among patients and leaders by measuring performance of the intervention according to protocol, attendance and adherence of the participating ICD patients, and patients' and leaders' opinions about the programme. In addition, before and directly after attending the intervention, programme benefits (e.g. perceived control, symptoms of anxiety and depression, and quality of life were assessed. Results The programme was conducted largely according to protocol. Eight patients attended at least four sessions, and adherence ranged from good to very good. On average, the patients reported to have benefited very much from the programme, which they gave an overall report mark of 8.4. The leaders considered the programme feasible as well. Furthermore, improvements were identified for general self-efficacy expectancies, symptoms of anxiety, physical functioning, social functioning, role limitations due to physical problems, and pain. Conclusion This study suggests that a self-management programme led by a

  20. Phantom shocks in patients with implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Moons, Philip; Zwisler, Ann-Dorthe

    2013-01-01

    of phantom shocks.METHODS AND RESULTS: The design was secondary explorative analyses of data from a randomized controlled trial. One hundred and ninety-six patients with first-time ICD implantation (79% male, mean age 58 years) were randomized (1 : 1) to either combined rehabilitation or a control group...... questions regarding the experience of phantom shocks, date, time, and place. Twelve patients (9.4%) experienced a phantom shock, 7 in the intervention group and 5 in the control group (NS). Neither age, sex, quality of life nor perceived health at baseline was significantly related to the probability...

  1. Design and Methods for a Pilot Study of a Phone-Delivered, Mindfulness-Based Intervention in Patients with Implantable Cardioverter Defibrillators

    Directory of Open Access Journals (Sweden)

    Elena Salmoirago-Blotcher

    2012-01-01

    Full Text Available Background. Meditation practices are associated with a reduction in adrenergic activity that may benefit patients with severe cardiac arrhythmias. This paper describes the design and methods of a pilot study testing the feasibility of a phone-delivered mindfulness-based intervention (MBI for treatment of anxiety in patients with implantable cardioverter defibrillators (ICDs. Design and Methods. Consecutive, clinically stable outpatients (n=52 will be screened for study eligibility within a month of an ICD-related procedure or ICD shock and will be randomly assigned to MBI or to usual care. MBI patients will receive eight weekly individual phone sessions based on two mindfulness practices (awareness of breath and body scan plus home practice with a CD for 20 minutes daily. Patients assigned to usual care will be offered the standard care planned by the hospital. Assessments will occur at baseline and at the completion of the intervention (between 9 and 12 weeks after randomization. The primary study outcome is feasibility; secondary outcomes include anxiety, mindfulness, and number of administered shocks during the intervention period. Conclusions. If proven feasible and effective, phone-delivered mindfulness-based interventions could improve psychological distress in ICD outpatients with serious cardiovascular conditions.

  2. A review of economic evaluation models for cardiac resynchronization therapy with implantable cardioverter defibrillators in patients with heart failure

    NARCIS (Netherlands)

    Tomini, F.; van Asselt, A. D.

    OBJECTIVES: Cardiac resynchronization therapy with biventricular pacemaker (CRT-P) is considered an effective treatment for heart failure (HF). Adding implantable cardioverter defibrillators (CRT-D) may further reduce the risk of sudden cardiac death (SCD). However, economic evaluations have shown

  3. A review of economic evaluation models for cardiac resynchronization therapy with implantable cardioverter defibrillators in patients with heart failure

    NARCIS (Netherlands)

    Tomini, F.; van Asselt, A. D.

    2012-01-01

    OBJECTIVES: Cardiac resynchronization therapy with biventricular pacemaker (CRT-P) is considered an effective treatment for heart failure (HF). Adding implantable cardioverter defibrillators (CRT-D) may further reduce the risk of sudden cardiac death (SCD). However, economic evaluations have shown

  4. Emotions and health: findings from a randomized clinical trial on psychoeducational nursing to patients with implantable cardioverter defibrillator.

    Science.gov (United States)

    Kikkenborg Berg, Selina; Støier, Louise; Moons, Philip; Zwisler, Ann-Dorthe; Winkel, Per; Ulrich Pedersen, Preben

    2015-01-01

    Serious illness will inevitably lead to a fundamental emotional reaction. Traditionally, in interventional treatment or rehabilitation trials, the psychological status of patients with implantable cardioverter defibrillators has been evaluated with anxiety and depression as outcome measures. In caring for these patients, the aim of nursing is to help patients manage life with complex heart disease. The early detection and management of negative emotional response might prevent the development of pathological conditions such as depression. The aims of this study were to (a) describe the trajectory of primary emotions over time in patients with implantable cardioverter defibrillators and (b) examine the potential effects of psychoeducational nursing on primary emotions. During the inclusion period (October 2007 to November 2009), 196 patients with implantable cardioverter defibrillator were randomized (1:1) to rehabilitation versus usual care. Rehabilitation consisted of a psychoeducational nursing component and an exercise training component. This article concerns phase 1, psychoeducational nursing, guided by a theory of nursing, Rosemary Rizzo Parses Human Becoming Practice Methodologies. The outcome measure is the Emotions and Health Scale. The scale consists of 8 primary emotions: joy, agreeableness, surprise, fear, sadness, disgust, anger, and anticipation. Mean (SD) age was 58 (13) years, and 79% of the participants were men. Significant improvements were found in primary emotional responses over time (P .05). Primary emotions are affected after implantable cardioverter defibrillator implantation. Improvements over time were found. However, it was not possible to detect any effect of a short-term psychoeducational nursing intervention. Evaluating the primary emotions might be a good way for nurses to monitor patients' psychological outcomes because the instrument is sensitive to changes over a short period. Further development of early psychoeducational nursing

  5. Inappropriate shocks in the subcutaneous ICD: Incidence, predictors and management

    NARCIS (Netherlands)

    Olde Nordkamp, Louise R. A.; Brouwer, Tom F.; Barr, Craig; Theuns, Dominic A. M. J.; Boersma, Lucas V. A.; Johansen, Jens B.; Neuzil, Petr; Wilde, Arthur A. M.; Carter, Nathan; Husby, Michael; Lambiase, Pier D.; Knops, Reinoud E.

    2015-01-01

    The entirely subcutaneous implantable cardioverter-defibrillator (S-ICD) eliminates the need for transvenous leads, and therefore has the potential to improve lead-longevity and reduce lead-related complications. The S-ICD has a morphology-based sensing algorithm of which inappropriate shocks have

  6. Patient satisfaction and suggestions for improvement of remote ICD monitoring

    DEFF Research Database (Denmark)

    Petersen, Helen Høgh; Larsen, Mie Christa Jensen; Nielsen, Olav Wendelboe

    2012-01-01

    PURPOSE: The study aim was to evaluate patient acceptance and content with remote follow-up (FU) of their implantable cardioverter defibrillator (ICD) and to estimate patients' wish for changes in remote follow-up routines. METHODS: Four hundred seventy-four ICD patients at the device follow-up c...

  7. MR Imaging in patients with cardiac pacemakers and implantable cardioverter defibrillators. Consensus paper of the German Cardiac Society and the German Roentgen Society; MR-Untersuchungen bei Patienten mit Herzschrittmachern und implantierbaren Kardioverter-Defibrillatoren. Konsensuspapier der Deutschen Gesellschaft fuer Kardiologie (DGK) und der Deutschen Roentgengesellschaft (DRG)

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, Torsten [DRK Krankenhaus, Neuwied (Germany). Klinik fuer Diagnostische und Interventionelle Radiologie; Bauer, Wolfgang [Deutsches Zentrum fuer Herzinsuffizienz Univ. Wuerzburg (Germany). Med. Klinik und Poliklinik I Univ. Klinikum Wuerzburg; Fischbach, Katharina [Universitaetsklinikum Magdeburg (Germany). Klinik fuer Radiologie und Nuklearmedizin; and others

    2017-03-15

    This joint consensus paper of the German Roentgen Society and the German Cardiac Society provides physical and electrophysiological background information and specific recommendations for the procedural management of patients with cardiac pacemakers (PM) and implantable cardioverter defibrillators (ICD) undergoing magnetic resonance (MR) imaging. The paper outlines the responsibilities of radiologists and cardiologists regarding patient education, indications, and monitoring with modification of MR sequences and PM/ICD reprogramming strategies being discussed in particular. The aim is to optimize patient safety and to improve legal clarity in order to facilitate the access of SM/ICD patients to MR imaging.

  8. The Role of Implantable Cardioverter Defibrillators in Patients Bridged to Transplantation with a Continuous Flow Left Ventricular Assist Device: A Propensity Score Matched Analysis

    Science.gov (United States)

    Clerkin, Kevin J.; Topkara, Veli K.; Mancini, Donna M.; Yuzefpolskaya, Melana; Demmer, Ryan T.; Dizon, Jose M.; Takeda, Koji; Takayama, Hiroo; Naka, Yoshifumi; Colombo, Paolo C.; Garan, A. Reshad

    2016-01-01

    Background Implantable cardioverter defibrillators (ICD) provide a significant mortality benefit for appropriately selected patients with advanced heart failure. ICDs are associated with a mortality benefit when used in patients with a pulsatile left ventricular assist device (LVAD). However it is unclear whether patients with a continuous flow LVAD (CF-LVAD) derive the same benefit. This study sought to determine if the presence of an ICD provided a mortality benefit during CFLVAD support as a bridge to transplantation. Methods Patients were identified in the United Network for Organ Sharing (UNOS) registry that underwent LVAD implantation as bridge to transplantation from May 2004 and April 2014, with follow-up through June 2014. The primary outcome was freedom from death while on CF-LVAD support with adjustment for complications requiring UNOS listing status upgrade. Secondary endpoints included freedom from delisting while on CF-LVAD support and incidence of transplantation. Results 2,990 patients composed the study cohort and propensity score matching identified 1,012 patients with similar propensity scores. There was no difference in survival during device support between patients with and without an ICD (Hazard Ratio [HR] 1.20, 95% Confidence Interval [CI] 0.66-2.17, p=0.55). Adjusting for device complications requiring a UNOS listing status upgrade had minimal influence (HR 1.11, 95% CI 0.60-2.05, p=0.74). There was no increased risk of delisting due to being too sick for those with an ICD (HR 1.08, 95% CI 0.63-1.86, p=0.78). Likewise, the probability of transplantation was similar (HR 1.05, 95% CI 0.87-1.27, p=0.62). Conclusions Among patients bridged to transplantation with a CF-LVAD, the presence of an ICD did not reduce mortality. PMID:28089072

  9. The role of implantable cardioverter defibrillators in patients bridged to transplantation with a continuous-flow left ventricular assist device: A propensity score matched analysis.

    Science.gov (United States)

    Clerkin, Kevin J; Topkara, Veli K; Mancini, Donna M; Yuzefpolskaya, Melana; Demmer, Ryan T; Dizon, Jose M; Takeda, Koji; Takayama, Hiroo; Naka, Yoshifumi; Colombo, Paolo C; Garan, A Reshad

    2017-06-01

    Implantable cardioverter defibrillators (ICDs) provide a significant mortality benefit for appropriately selected patients with advanced heart failure. ICDs are associated with a mortality benefit when used in patients with a pulsatile left ventricular assist device (LVAD). It is unclear whether patients with a continuous-flow LVAD (CF-LVAD) derive the same benefit. We sought to determine if the presence of an ICD provided a mortality benefit during CF-LVAD support as a bridge to transplantation. Patients were identified in the United Network for Organ Sharing (UNOS) registry who underwent LVAD implantation as bridge to transplantation between May 2004 and April 2014, with follow-up through June 2014. Primary outcome was freedom from death while on CF-LVAD support with adjustment for complications requiring UNOS listing status upgrade. Secondary end-points included freedom from delisting while on CF-LVAD support and incidence of transplantation. The study cohort comprised 2,990 patients, and propensity score matching identified 1,012 patients with similar propensity scores. There was no difference in survival during device support between patients with and without an ICD (hazard ratio [HR] = 1.20; 95% confidence interval [CI], 0.66-2.17; p = 0.55). Adjusting for device complications requiring a UNOS listing status upgrade had minimal influence (HR = 1.11; 95% CI, 0.60-2.05; p = 0.74). There was no increased risk of delisting owing to being too sick for patients with an ICD (HR = 1.08; 95% CI, 0.63-1.86; p = 0.78). Likewise, the probability of transplantation was similar (HR = 1.05; 95% CI, 0.87-1.27; p = 0.62). Among patients bridged to transplantation with a CF-LVAD, the presence of an ICD did not reduce mortality. Copyright © 2017 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  10. The learning curve associated with the introduction of the subcutaneous implantable defibrillator

    NARCIS (Netherlands)

    Knops, Reinoud E.; Brouwer, Tom F.; Barr, Craig S.; Theuns, Dominic A.; Boersma, Lucas; Weiss, Raul; Neuzil, Petr; Scholten, Marcoen; Lambiase, Pier D.; Leon, Angel R.; Hood, Margaret; Jones, Paul W.; Wold, Nicholas; Grace, Andrew A.; Olde Nordkamp, Louise R. A.; Burke, Martin C.

    2016-01-01

    Aims The subcutaneous implantable cardioverter defibrillator (S-ICD) was introduced to overcome complications related to transvenous leads. Adoption of the S-ICD requires implanters to learn a new implantation technique. The aim of this study was to assess the learning curve for S-ICD implanters

  11. The learning curve associated with the introduction of the subcutaneous implantable defibrillator

    NARCIS (Netherlands)

    R.E. Knops (Reinoud); T.F. Brouwer (Tom F.); C.S. Barr (Craig); D.A.M.J. Theuns (Dominic); L. Boersma (Lucas); R. Weiss (Ram); P. Neuzil (Petr); M.F. Scholten (Marcoen); P.D. Lambiase (Pier); A. Leon (Angel); A.M. Hood (Margaret); P. Jones; Wold, N. (Nicholas); Grace, A.A. (Andrew A.); L.R.A. Olde Nordkamp (Louise R.A.); M.C. Burke (Martin)

    2016-01-01

    textabstractAims: The subcutaneous implantable cardioverter defibrillator (S-ICD) was introduced to overcome complications related to transvenous leads. Adoption of the S-ICD requires implanters to learn a new implantation technique. The aim of this study was to assess the learning curve for S-ICD

  12. Long-Term Clinical Outcomes of Subcutaneous Versus Transvenous Implantable Defibrillator Therapy

    NARCIS (Netherlands)

    Brouwer, Tom F.; Yilmaz, Dilek; Lindeboom, Robert; Buiten, Maurits S.; Olde Nordkamp, Louise R. A.; Schalij, Martin J.; Wilde, Arthur A.; van Erven, Lieselot; Knops, Reinoud E.

    2016-01-01

    Transvenous implantable cardioverter-defibrillators (TV-ICDs) improve survival in patients at risk for sudden cardiac death, but complications remain an important drawback. The subcutaneous ICD (S-ICD) was developed to overcome lead-related complications. Comparison of clinical outcomes of both

  13. [Safety of cardiac pacemakers and implantable cardioverter-defibrillators in magnetic resonance imaging. Assessment of the aggregate function at 1.5 tesla].

    Science.gov (United States)

    Nordbeck, P; Bauer, W R

    2008-03-01

    Magnetic resonance imaging (MRI) is increasingly used in patients, but it is contraindicated in those with cardiac pacemakers (CP) or implantable cardioverter defibrillators (ICD). This study examined circumstances in which potentially life-threatening arrhythmias may be triggered in patients with CP undergoing MRI and whether these problems can be avoided by reprogramming of these devices. Eight CP and seven ICDs were investigated in a phantom at 1.5 tesla (experimental and imaging sequences). A decrease in battery voltage was found in four CP after MRI (indication for elective replacement). Additionally, three showed changes in programming (resets). Analogous changes did not appear in the tested ICDs, but periods of tachycardia were recorded in all types of devices during MRI depending on the pulse sequence employed. MRI-related electromagnetic fields as used in routine MRI can induce severe pacemaker device malfunctions. Device programming approaches are unreliable for prevention of patient hazards, as programming changes or resets are one of the primary malfunctions during MRI.

  14. Radiation therapy in patients with cardiac pacemakers or implantable cardioverter defibrillators. Interdisciplinary safety recommendations; Strahlentherapie bei Patienten mit Herzschrittmachern oder implantierbaren Kardioverter-Defibrillatoren. Interdisziplinaere Sicherheitsempfehlungen

    Energy Technology Data Exchange (ETDEWEB)

    Dorenkamp, M.; Haverkmap, W.; Roser, M. [Charite Universitaetsmedizin Berlin, Campus Virchow-Klinikum (Germany). Medizinische Klinik mit Schwerpunkt Kardiologie; Stromberger, C.; Wust, P. [Charite Universitaetsmedizin Berlin (Germany). Klinik fuer Radioonkologie und Strahlentherapie; Heymann, C. von [Charite Universitaetsmedizin Berlin, Campus Virchow-Klinikum (Germany). Klinik fuer Anaesthesiologie mit Schwerpunkt operative Intensivmedizin

    2013-01-15

    Background: With increasing numbers of implanted pacemakers and implantable cardioverter defibrillators (ICD) and a rising incidence of malignant tumors, there is a growing probability of radiation-mediated device dysfunction. The only guidelines for the management of patients with cardiac pacemakers in the case of radiation therapy were published in 1994 and have not been updated since then. Based on the current evidence and modern device technology, the present paper aims to develop contemporary and interdisciplinary safety recommendations for the minimization of patient risk. Methods and results: A systematic literature research was carried out including the most relevant medical electronic databases. The search yielded 147 articles published between 1994 and 2012 of which 45 met the selection criteria and of these studies 34 presented primary data (9 in vitro and 25 in vivo studies). The impact of ionizing radiation varied significantly between implanted devices and ranged from no functional changes to complete loss of function. Important device dysfunctions included changes in sensing capability, altered pacing pulses or rate, changed or disabled tachyarrhythmia ICD therapies, early battery depletion and loss of telemetry. Modern pacemakers and ICDs are more sensitive to radiation than older models. Potentially life-threatening complications were observed after exposure of the pulse generator to comparatively low radiation doses (0.11 Gy). Conclusions: Practical recommendations for patient management and safety are presented that can be readily adopted by any institution carrying out radiation therapy. (orig.)

  15. Development and evaluation of the EOL-ICDQ as a measure of experiences, attitudes and knowledge in end-of-life in patients living with an implantable cardioverter defibrillator.

    Science.gov (United States)

    Thylén, Ingela; Wenemark, Marika; Fluur, Christina; Strömberg, Anna; Bolse, Kärstin; Årestedt, Kristofer

    2014-04-01

    Due to extended indications and resynchronization therapy, many implantable cardioverter defibrillator (ICD) recipients will experience progressive co-morbid conditions and will be more likely to die of causes other than cardiac death. It is therefore important to elucidate the ICD patients' preferences when nearing end-of-life. Instead of avoiding the subject of end-of-life, a validated questionnaire may be helpful to explore patients' experiences and attitudes about end-of-life concerns and to assess knowledge of the function of the ICD in end-of-life. Validated instruments assessing patients' perspective concerning end-of-life issues are scarce. The purpose of this study was to develop and evaluate respondent satisfaction and measurement properties of the 'Experiences, Attitudes and Knowledge of End-of-Life Issues in Implantable Cardioverter Defibrillator Patients' Questionnaire' (EOL-ICDQ). The instrument was tested for validity, respondent satisfaction, and for homogeneity and stability in the Swedish language. An English version of the EOL-ICDQ was validated, but has not yet been pilot tested. The final instrument contained three domains, which were clustered into 39 items measuring: experiences (10 items), attitudes (18 items), and knowledge (11 items) of end-of-life concerns in ICD patients. In addition, the questionnaire also contained items on socio-demographic background (six items) and ICD-specific background (eight items). The validity and reliability properties were considered sufficient. The EOL-ICDQ has the potential to be used in clinical practice and future research. Further studies are needed using this instrument in an Anglo-Saxon context with a sample of English-speaking ICD recipients.

  16. The healthcare utilization and cost of treating patients experiencing inappropriate implantable cardioverter defibrillator shocks: a propensity score study.

    Science.gov (United States)

    Bhavnani, Sanjeev P; Giedrimiene, Dalia; Coleman, Craig I; Guertin, Danette; Azeem, Meena; Kluger, Jeffrey

    2014-10-01

    Inappropriate shocks (IASs) from implantable cardioverter defibrillators (ICDs) are associated with decreased quality of life, but whether they increase healthcare utilization and treatment costs is unknown. We sought to determine the impact of IASs on subsequent healthcare utilization and treatment costs. We conducted a case-control analysis of ICD patients at a single institution from 1997 to 2010 and who had ≥12 months of post-ICD implant follow-up. Cases included all patients experiencing an IAS during the first 12 months after implantation. Eligible control patients did not receive a shock of any kind during the 12 months after implantation. Propensity scores based on 36 covariates (area under curve = 0.78) were used to match cases to controls. We compared the rate (occurrences/person year [PY]) of healthcare utilization immediately following IAS to the end of the 12-month follow-up period to the rate in the no-shock group over 12 months of follow-up. We also compared 12-month postimplant treatment (outpatient clinic, emergency room, and hospitalization) costs in both groups. A total of 76 patients experiencing ≥1 IAS during the first 12 months after implant (contributing 48 PYs) were matched to 76 no-shock patients (contributing 76 PYs). Cardiovascular (CV)-related clinic visit and hospitalization rates were increased following an IAS compared to those not receiving a shock (4.0 vs 3.3 and 0.7 vs 0.5, respectively, P = 0.02 for both). CV-related emergency room visitation (0.15 vs 0.08) rates were also numerically higher following an IAS, but did not reach statistical significance (P = 0.26). Patients experiencing an IAS accrued greater treatment costs during the 12 months postimplant compared to no-shock patients ($13,973 ± $46,345 vs $6,790 ± $19,091, P = 0.001). Recipients of IAS utilize the healthcare system more frequently following an IAS than patients not experiencing a shock. This increased utilization results in higher costs of treating IAS

  17. [The pacemaker and implantable cardioverter-defibrillator registry of the Italian Association Arrhythmology Cardiac Pacing and cardiac pacing - annual report 2013].

    Science.gov (United States)

    Proclemer, Alessandro; Zecchin, Massimo; D'Onofrio, Antonio; Botto, Giovanni Luca; Rebellato, Luca; Ghidina, Marco; Bianco, Giulia; Bernardelli, Emanuela; Pucher, Elsa; Gregori, Dario

    2014-11-01

    The pacemaker (PM) and implantable cardioverter-defibrillator (ICD) Registry of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) monitors the main epidemiological data in real-world practice. The survey for the 2013 activity collects information about demographics, clinical characteristics, main indications for PM/ICD therapy and device types from the Italian collaborating centers. The Registry collects prospectively national PM and ICD implantation activity on the basis of European cards. PM Registry: data about 25 419 PM implantations were collected (19 134 first implant and 6285 replacements). The number of collaborating centers was 275. Median age of treated patients was 80 years (74 quartile I; 86 quartile III). ECG indications included atrioventricular conduction disorders in 43.6% of first PM implants, sick sinus syndrome in 24.7%, atrial fibrillation plus bradycardia in 12.9%, other in 18.8%. Among atrioventricular conduction defects, third-degree atrioventricular block was the most common type (23.2% of first implants). Use of single-chamber PMs was reported in 27.2% of first implants, of dual-chamber PMs in 62.6%, of PMs with cardiac resynchronization therapy (CRT) in 1.8%, and of single lead atrial-synchronized ventricular stimulation (VDD/R PMs) in 8.4%. ICD Registry: data about 16 519 ICD implantations were collected (11 474 first implants and 5045 replacements). The number of collaborating centers was 430. Median age of treated patients was 71 years (63 quartile I; 77 quartile III). Primary prevention indication was reported in 76% of first implants, secondary prevention in 24.0% (cardiac arrest in 7.8%). A single-chamber ICD was used in 27.2% of first implants, dual-chamber in 35.9% and biventricular in 36.8%. The PM and ICD Registry appears fundamental for monitoring PM and ICD utilization on a large national scale with rigorous examination of demographics and clinical indications. The PM Registry showed stable electrocardiographic

  18. Prophylactic implantable defibrillator in patients with arrhythmogenic right ventricular cardiomyopathy/dysplasia and no prior ventricular fibrillation or sustained ventricular tachycardia.

    LENUS (Irish Health Repository)

    Corrado, Domenico

    2010-09-21

    The role of implantable cardioverter-defibrillator (ICD) in patients with arrhythmogenic right ventricular cardiomyopathy\\/dysplasia and no prior ventricular fibrillation (VF) or sustained ventricular tachycardia is an unsolved issue.

  19. Pacemakers and implantable cardioverter defibrillators, unknown to chest radiography: Review, complications and systematic reading

    International Nuclear Information System (INIS)

    Alandete Germán, Salvador Pascual; Isarria Vidal, Santiago; Domingo Montañana, María Luisa; De la vía Oraá, Esperanza; Vilar Samper, José

    2015-01-01

    Highlights: •Radiologists have an important function in the evaluation of these devices. •We revise their radiological appearances and possible complications. •The knowledge in normal aspects and complications is important for radiologist. •To ensure an accurate reading of the chest x-ray, we present a systematic approach. -- Abstract: Chest X-ray is the imaging technique of choice for an initial study of pacemakers and implantable cardio-defibrillators (ICD). Radiologists have an important role in the evaluation of its initial placement and in the assessment during its follow-up. For this reason, it is necessary to know not only the different existing devices and its components but also the reasons of malfunction or possible complications. The purpose of this article is to do a systematic review of the different types of pacemakers and ICD. We review their usual radiological appearances, the possible complications which might take place and its causes of malfunctioning

  20. General anaesthesia for insertion of an automated implantable cardioverter defibrillator in a child with Brugada and autism

    Directory of Open Access Journals (Sweden)

    Shwetal Goraksha

    2010-01-01

    Full Text Available A 14-year-old autistic boy presented with acute gastroenteritis and hypotension. The electrocardiogram showed a ventricular fibrillation rhythm - he went into cardiorespiratory arrest and was immediately resuscitated. On investigation, the electrocardiogram showed a partial right bundle branch block with a "coved" pattern of ST elevation in leads v 1 -v 3 . A provisional diagnosis of Brugada syndrome was made, for which an automated implantable cardioverter defibrillator (AICD implantation was advised. Although the automated implantable cardioverter defibrillator implantation is usually performed under sedation, because this was an autistic child, he needed general anaesthesia. We performed the procedure uneventfully under general anaesthesia and he was discharged after a short hospital stay.

  1. Psychometric properties of HeartQoL, a core heart disease-specific health-related quality of life questionnaire, in Danish implantable cardioverter defibrillator recipients

    DEFF Research Database (Denmark)

    Zangger, Graziella; Zwisler, Ann-Dorthe; Kikkenborg Berg, Selina

    2018-01-01

    disease-specific health-related quality of life questionnaire, in implantable cardioverter defibrillator recipients. Design This study involved cross-sectional and test-retest study designs. Method Implantable cardioverter defibrillator recipients in the cross-sectional study completed the Heart......QoL, the Short-Form 36 Health Survey, and the Hospital Anxiety and Depression Scale. The HeartQoL structure, construct-related validity (convergent and discriminative) and reliability (internal consistency) were assessed. HeartQoL reproducibility (test-retest) was assessed in an independent sample of implantable...... psychometric attributes of validity and reliability in this implantable cardioverter defibrillator population. This study adds support for the HeartQoL as a core heart-specific health-related quality of life questionnaire in a broad group of patients with heart disease including implantable cardioverter...

  2. Polymorphisms associated with ventricular tachyarrhythmias: rationale, design, and endpoints of the 'diagnostic data influence on disease management and relation of genomics to ventricular tachyarrhythmias in implantable cardioverter/defibrillator patients (DISCOVERY)' study

    DEFF Research Database (Denmark)

    Wieneke, Heinrich; Spencker, Sebastian; Svendsen, Jesper Hastrup

    2010-01-01

    Implantable cardioverter-defibrillator (ICD) therapy is effective in primary and secondary prevention for patients who are at high risk of sudden cardiac death. However, the current risk stratification of patients who may benefit from this therapy is unsatisfactory. Single nucleotide polymorphism...... pathways will be investigated. As it is a diagnostic study, DISCOVERY will also investigate the impact of long-term device diagnostic data on the management of patients suffering from chronic cardiac disease as well as medical decisions made regarding their treatment.......Implantable cardioverter-defibrillator (ICD) therapy is effective in primary and secondary prevention for patients who are at high risk of sudden cardiac death. However, the current risk stratification of patients who may benefit from this therapy is unsatisfactory. Single nucleotide polymorphisms...... modulate the risk for arrhythmias and sudden cardiac death, and identification of common variants could help to better identify patients at risk. The DISCOVERY study is an interventional, longitudinal, prospective, multi-centre diagnostic study that will enrol 1287 patients in approximately 80 European...

  3. Inappropriate shock and battery switching to "End of Life" in a patient with biventricular ICD during magnetic resonance imaging.

    Science.gov (United States)

    Atar, İlyas; Bal, Uğur; Ertan, Çağatay; Özin, Bülent; Müderrisoğlu, Haldun

    2016-01-01

    Presence of a cardiac pacemaker or implantable cardioverter defibrillator (ICD) is a relative contraindication to magnetic resonance imaging (MRI). Biventricular ICDs are often used in the treatment of advanced heart failure; however, reports on experience with biventricular ICDs are lacking in the literature. In this case report, we describe a pacemaker-dependent patient with a biventricular ICD on whom an MRI of the lumbar spine was performed without having realized the presence of the ICD.

  4. An unusual etiological agent of implantable cardioverter device endocarditis: Corynebacterium mucifaciens

    Directory of Open Access Journals (Sweden)

    Adnan Kaya

    2016-03-01

    Full Text Available Cardiac pacing devices and implantable cardioverter defibrillator (ICD are becoming the mainstay of therapy in cardiology and infective endocarditis (IE and pocket infection; however, these devices require careful monitoring. Here, we describe a case of a 68-year-old female with an ICD presenting with a previously unknown etiological agent of IE, Corynebacterium mucifaciens.

  5. Association between socioeconomic factors and ICD implantation in a publicly financed health care system

    DEFF Research Database (Denmark)

    Winther-Jensen, Matilde; Hassager, Christian; Lassen, Jens Flensted

    2017-01-01

    Aims: For patients surviving out-of-hospital cardiac arrest (OHCA) with a shockable rhythm, implantable cardioverter defibrillator (ICD) is recommended for non-reversible causes of arrest. We aimed to determine factors associated with implantation of ICD and survival in patients surviving non...... admission. Association to ICD implantation during index admission was analysed in logistic regression, survival was assessed using Cox regression. Implantable cardioverter defibrillator implantation increased during the study period [odds ratio (OR) 1-year increase: 1.04, 95% confidence intervals (95% CI...

  6. Importance of beta-blocker dose in prevention of ventricular tachyarrhythmias, heart failure hospitalizations, and death in primary prevention implantable cardioverter-defibrillator recipients

    DEFF Research Database (Denmark)

    Ruwald, A C; Gislason, G H; Vinther, M

    2018-01-01

    Aims: There is a paucity of studies investigating a dose-dependent association between beta-blocker therapy and risk of outcome. In a nationwide cohort of primary prevention implantable cardioverter-defibrillator (ICD) patients, we aimed to investigate the dose-dependent association between beta-blocker...... therapy and risk of ventricular tachyarrhythmias (VT/VF), heart failure (HF) hospitalizations, and death. Methods and results: Information on ICD implantation, endpoints, comorbidities, beta-blocker usage, type, and dose were obtained through Danish nationwide registers. The two major beta-blockers...... carvedilol and metoprolol were examined in three dose levels; low (metoprolol ≤ 25 mg; carvedilol ≤ 12.5 mg), intermediate (metoprolol 26-199 mg; carvedilol 12.6-49.9 mg), and high (metoprolol ≥ 200 mg; carvedilol ≥ 50 mg). Time to events was investigated utilizing multivariate Cox models with beta-blocker...

  7. Detection of atrial fibrillation and flutter by a dual-chamber implantable cardioverter-defibrillator. For the Worldwide Jewel AF Investigators.

    Science.gov (United States)

    Swerdlow, C D; Schsls, W; Dijkman, B; Jung, W; Sheth, N V; Olson, W H; Gunderson, B D

    2000-02-29

    To distinguish prolonged episodes of atrial fibrillation (AF) that require cardioversion from self-terminating episodes that do not, an atrial implantable cardioverter-defibrillator (ICD) must be able to detect AF continuously for extended periods. The ICD should discriminate between atrial tachycardia/flutter (AT), which may be terminated by antitachycardia pacing, and AF, which requires cardioversion. We studied 80 patients with AT/AF and ventricular arrhythmias who were treated with a new atrial/dual-chamber ICD. During a follow-up period lasting 6+/-2 months, we validated spontaneous, device-defined AT/AF episodes by stored electrograms in all patients. In 58 patients, we performed 80 Holter recordings with telemetered atrial electrograms, both to validate the continuous detection of AT/AF and to determine the sensitivity of the detection of AT/AF. Detection was appropriate in 98% of 132 AF episodes and 88% of 190 AT episodes (98% of 128 AT episodes with an atrial cycle length 1 hour, for a total of 2697 hours of continuous detection of AT/AF. During Holter monitoring, the sensitivity of the detection of AT/AF (116 hours) was 100%; the specificity of the detection of non-AT/AF rhythms (1290 hours) was 99.99%. Of 166 appropriate episodes detected as AT, 45% were terminated by antitachycardia pacing. A new ICD detects AT/AF accurately and continuously. Therapy may be programmed for long-duration AT/AF, with a low risk of underdetection. Discrimination of AT from AF permits successful pacing therapy for a significant fraction of AT.

  8. Implantable Cardioverter-Defibrillators in Patients With a Continuous-Flow Left Ventricular Assist Device: An Analysis of the INTERMACS Registry.

    Science.gov (United States)

    Clerkin, Kevin J; Topkara, Veli K; Demmer, Ryan T; Dizon, Jose M; Yuzefpolskaya, Melana; Fried, Justin A; Mai, Xingchen; Mancini, Donna M; Takeda, Koji; Takayama, Hiroo; Naka, Yoshifumi; Colombo, Paolo C; Garan, A Reshad

    2017-12-01

    This study sought to determine if the presence of implantable cardioverter-defibrillators (ICD) provided a mortality benefit during continuous-flow left ventricular assist device (LVAD) support. An ICD decreases mortality in selected patients with advanced heart failure and have been associated with reduced mortality in patients with pulsatile LVAD. However, it is unclear whether that benefit extends to patients with a contemporary continuous-flow LVAD. Propensity score matching was used to generate a cohort of patients with similar baseline characteristics. The primary outcome was freedom from death during LVAD support. Secondary endpoints included freedom from unexpected death, likelihood of transplantation and recovery, and adverse events. Among 16,384 eligible patients in the Interagency Registry for Mechanically Assisted Circulatory Support registry, 2,209 patients with an ICD and 2,209 patients without one had similar propensity scores and were included. The presence of an ICD was associated with an increased mortality risk (hazard ratio: 1.20; 95% confidence interval [CI]: 1.04 to 1.39; p = 0.013) and an increased risk of unexpected death during device support (HR: 1.33; 95% CI: 1.03 to 1.71; p = 0.03). Patients with an ICD were more likely to undergo transplantation (HR: 1.16; 95% CI: 0.99 to 1.35; p = 0.06) and less likely to have LVAD explant for recovery (HR: 0.53, 95% CI: 0.29 to 0.98; p = 0.04). Patients with an ICD had a higher rate of treated ventricular arrhythmias (rate ratio: 1.27; 95% CI: 1.10 to 1.48; p = 0.001) and rehospitalization (rate ratio: 1.08; 95% CI: 1.04 to 1.12; p < 0.0001), but rates of hemorrhagic stroke were similar (rate ratio: 1.01; 95% CI: 0.81 to 1.26; p = 0.98). Among patients with a continuous flow LVAD, the presence of an ICD was not associated with reduced mortality. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  9. Rapid-rate nonsustained ventricular tachycardia found on implantable cardioverter-defibrillator interrogation: relationship to outcomes in the SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial).

    Science.gov (United States)

    Chen, Jay; Johnson, George; Hellkamp, Anne S; Anderson, Jill; Mark, Daniel B; Lee, Kerry L; Bardy, Gust H; Poole, Jeanne E

    2013-05-28

    The aim of this study was to examine rapid-rate nonsustained ventricular tachycardia (RR-NSVT) during routine implantable cardioverter-defibrillator (ICD) evaluation in patients with heart failure and its relationship to outcomes. The clinical implications of RR-NSVT identified during routine ICD interrogation are unclear. In this study, the occurrence of RR-NSVT and its association with ICD shocks and mortality in SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial) were examined. The 811 patients who received ICDs in SCD-HeFT constituted the study population. The occurrence of RR-NSVT and its association with ICD shocks and mortality in SCD-HeFT were examined. RR-NSVT was documented on ICD interrogation in 186 of 811 patients (22.9%). The mean duration of RR-NSVT was 26.4 ± 9.1 beats (7.5 ± 2.6 s), with a mean cycle length of 259 ± 32 ms. Polymorphic RR-NSVT accounted for 56% of episodes. Compared with patients without RR-NSVT, those with RR-NSVT were less likely to be taking beta-blockers, statins, or aspirin at enrollment. After adjusting for other known predictors of mortality in SCD-HeFT, RR-NSVT was independently associated with appropriate ICD shocks (hazard ratio: 4.25; 95% confidence interval: 2.94 to 6.14; p interrogation should be considered an important clinical event. RR-NSVT during ICD interrogation is associated with appropriate ICD shocks and all-cause mortality. The clinical evaluation of patients with RR-NSVT should include intensification of medical therapy, particularly beta-blockers, or other appropriate clinical interventions. (Sudden Cardiac Death in Heart Failure Trial [SCD-HeFT]; NCT00000609). Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  10. Cardiac sympathetic innervation assessed with (123)I-MIBG retains prognostic utility in diabetic patients with severe left ventricular dysfunction evaluated for primary prevention implantable cardioverter-defibrillator.

    Science.gov (United States)

    García-González, P; Fabregat-Andrés, Ó; Cozar-Santiago, P; Sánchez-Jurado, R; Estornell-Erill, J; Valle-Muñoz, A; Quesada-Dorador, A; Payá-Serrano, R; Ferrer-Rebolleda, J; Ridocci-Soriano, F

    2016-01-01

    Scintigraphy with iodine-123-metaiodobenzylguanidine ((123)I-MIBG) is a non-invasive tool for the assessment of cardiac sympathetic innervation (CSI) that has proven to be an independent predictor of survival. Recent studies have shown that diabetic patients with heart failure (HF) have a higher deterioration in CSI. It is unknown if (123)I-MIBG has the same predictive value for diabetic and non-diabetic patients with advanced HF. An analysis is performed to determine whether CSI with (123)I-MIBG retains prognostic utility in diabetic patients with HF, evaluated for a primary prevention implantable cardioverter-defibrillator (ICD). Seventy-eight consecutive HF patients (48 diabetic) evaluated for primary prevention ICD implantation were prospectively enrolled and underwent (123)I-MIBG to assess CSI (heart-to-mediastinum ratio - HMR). A Cox proportional hazards multivariate analysis was used to determine the influence of (123)I-MIBG images for prediction of cardiac events in both diabetic and non-diabetic patients. The primary end-point was a composite of arrhythmic event, cardiac death, or admission due to HF. During a mean follow-up of 19.5 [9.3-29.3] months, the primary end-point occurred in 24 (31%) patients. Late HMR was significantly lower in diabetic patients (1.30 vs. 1.41, p=0.014). Late HMR≤1.30 was an independent predictor of cardiac events in diabetic (hazard ratio 4.53; p=0.012) and non-diabetic patients (hazard ratio 12.31; p=0.023). Diabetic patients with HF evaluated for primary prevention ICD show a higher deterioration in CSI than non-diabetics; nevertheless (123)I-MIBG imaging retained prognostic utility for both diabetic and non-diabetic patients. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  11. Cardiac pacing systems and implantable cardiac defibrillators (ICDs): a radiological perspective of equipment, anatomy and complications

    Energy Technology Data Exchange (ETDEWEB)

    Burney, K. E-mail: apqz59@dsl.pipex.comk1511@hotmail.com; Burchard, F.; Papouchado, M.; Wilde, P

    2004-08-01

    Cardiac pacing is a proven and effective treatment in the management of many cardiac arrhythmias. Implantable cardiac defibrillators (ICDs) are beneficial for certain patient groups with a history of serious, recurrent ventricular dysrhythmias, with a high risk of sudden cardiac death. Pacemaker devices take many forms and are highly visible on the chest radiograph. The radiographic appearances of ICDs and pacemakers can be similar and are subject to similar complications. The anatomical approach to the implantation, the type of device used and anatomical variations will all affect the appearance of these devices on the chest film. Pacemaker complications identified radiographically include pneumothorax, lead malpositioning, lead displacement or fracture, fracture of outer conductor coil, loose connection between the lead and pacemaker connector block, lack of redundant loops in paediatric patients and excessive manipulation of the device by the patient (Twiddler's syndrome). This pictorial review highlights the role of chest radiography in the diagnosis of post-cardiac pacing and ICD insertion complications, as well as demonstrating the normal appearances of the most frequently implanted devices.

  12. Electromagnetic interference from welding and motors on implantable cardioverter-defibrillators as tested in the electrically hostile work site.

    Science.gov (United States)

    Fetter, J G; Benditt, D G; Stanton, M S

    1996-08-01

    This study was designed to determine the susceptibility of an implanted cardioverter-defibrillator to electromagnetic interference in an electrically hostile work site environment, with the ultimate goal of allowing the patient to return to work. Normal operation of an implanted cardioverter-defibrillator depends on reliable sensing of the heart's electrical activity. Consequently, there is concern that external electromagnetic interference from external sources in the work place, especially welding equipment or motor-generator systems, may be sensed and produce inappropriate shocks or abnormal reed switch operation, temporarily suspending detection of ventricular tachycardia or ventricular fibrillation. The effects of electromagnetic interference on the operation of one type of implantable cardioverter-defibrillator (Medtronic models 7217 and 7219) was measured by using internal event counter monitoring in 10 patients operating arc welders at up to 900 A or working near 200-hp motors and 1 patient close to a locomotive starter drawing up to 400 A. The electromagnetic interference produced two sources of potential interference on the sensing circuit or reed switch operation, respectively: 1) electrical fields with measured frequencies up to 50 MHz produced by the high currents during welding electrode activation, and 2) magnetic fields produced by the current in the welding electrode and cable. The defibrillator sensitivity was programmed to the highest (most sensitive) value: 0.15 mV (model 7219) or 0.3 mV (model 7217). The ventricular tachycardia and ventricular fibrillation therapies were temporarily turned off but the detection circuits left on. None of the implanted defibrillators tested were affected by oversensing of the electric field as verified by telemetry from the detection circuits. The magnetic field from 225-A welding current produced a flux density of 1.2 G; this density was not adequate to close the reed switch, which requires approximately 10 G

  13. Mechanical dispersion and global longitudinal strain by speckle tracking echocardiography: Predictors of appropriate implantable cardioverter defibrillator therapy in hypertrophic cardiomyopathy.

    Science.gov (United States)

    Candan, Ozkan; Gecmen, Cetin; Bayam, Emrah; Guner, Ahmet; Celik, Mehmet; Doğan, Cem

    2017-06-01

    In this study, we investigated whether mechanical dispersion which reflects electrical abnormality and other echocardiographic and clinic parameters predict appropriate ICD shock in patients undergone ICD implantation for hypertrophic cardiomyopathy. Sixty-three patients who received ICD implantation for primary or secondary prevention were included in the study. Patients' clinical, electrocardiographic, 2D classic, and speckle tracking echocardiographic data were collected. Mechanical dispersion was defined as the standard deviation of time to peak negative strain in 18 left ventricular segments. Appropriate ICD therapy was defined as cardioversion or defibrillation due to ventricular tachycardia or fibrillation. Patients were divided into two groups as occurrence or the absence of appropriate ICD therapy. A total of 17 (26.9%) patients were observed to have an appropriate ICD therapy during follow-up periods. In patients who performed appropriate ICD therapy, a larger left atrial volume index, higher sudden cardiac death (SCD)-Risk Score, longer mechanical dispersion, and decreased global longitudinal peak strain (GLPS) were observed. In multivariate logistic regression analysis, including (GLPS, mechanical dispersion, LAVi, and SCD-Risk Score) was used to determine independent predictors of occurrence of appropriate ICD therapy during the follow-up. Mechanical dispersion, GLPS, and SCD-Risk Score were found to be independent predictors of occurrence of appropriate ICD therapy. Mechanical dispersion, GLPS, and SCD-Risk Score were found to be predictive for appropriate ICD therapy in patients receiving ICD implantation. Readily measurable mechanical dispersion and GLPS could be helpful to distinguish patients at high risk who could optimally benefit from ICD therapy. © 2017, Wiley Periodicals, Inc.

  14. Sustaining cyborgs: sensing and tuning agencies of pacemakers and implantable cardioverter defibrillators.

    Science.gov (United States)

    Oudshoorn, Nelly

    2015-02-01

    Recently there has been a renewed interest in cyborgs, and particularly in new and emerging fusions of humans and technologies related to the development of human enhancement technologies. These studies reflect a trend to follow new and emerging technologies. In this article, I argue that it is important to study 'older' and more familiar cyborgs as well. Studying 'the old' is important because it enables us to recognize hybrids' embodied experiences. This article addresses two of these older hybrids: pacemakers and implantable cardioverter defibrillators inserted in the bodies of people suffering from heart-rhythm disturbances. My concern with hybrid bodies is that internal devices seem to present a complex and neglected case if we wish to understand human agency. Their 'users' seem to be passive because they cannot exert any direct control over the working of their devices. Technologies inside bodies challenge a longstanding tradition of theorizing human-technology relations only in terms of technologies external to the body. Cyborg theory is problematic as well because most studies tend to conceptualize the cyborg merely as a discursive entity and silence the voices of people living as cyborgs. Inspired by feminist research that foregrounds the materiality of the lived and intimate relations between bodies and technologies, I argue that creating these intimate relations requires patients' active involvement in sustaining their hybrid bodies. Based on observations of these monitoring practices in a Dutch hospital and interviews with patients and technicians, the article shows that heart cyborgs are far from passive. On the contrary, their unique experience in sensing the entangled agencies of technologies and their own heart plays a crucial role in sustaining their hybrid bodies.

  15. Is metal artefact reduction mandatory in cardiac PET/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

    Energy Technology Data Exchange (ETDEWEB)

    Ghafarian, Pardis [Shahid Beheshti University, Department of Radiation Medicine, Tehran (Iran, Islamic Republic of); Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Tehran University of Medical Sciences, Research Center for Science and Technology in Medicine, Tehran (Iran, Islamic Republic of); Aghamiri, S.M.R. [Shahid Beheshti University, Department of Radiation Medicine, Tehran (Iran, Islamic Republic of); Ay, Mohammad R. [Tehran University of Medical Sciences, Research Center for Science and Technology in Medicine, Tehran (Iran, Islamic Republic of); Tehran University of Medical Sciences, Department of Medical Physics and Biomedical Engineering, Tehran (Iran, Islamic Republic of); Tehran University of Medical Sciences, Research Institute for Nuclear Medicine, Tehran (Iran, Islamic Republic of); Rahmim, Arman [Johns Hopkins University, Department of Radiology, Baltimore, MD (United States); Schindler, Thomas H. [Geneva University, Cardiovascular Center, Nuclear Cardiology, Geneva (Switzerland); Ratib, Osman [Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Zaidi, Habib [Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Geneva University, Geneva Neuroscience Center, Geneva (Switzerland)

    2011-02-15

    Cardiac PET/CT imaging is often performed in patients with pacemakers and implantable cardioverter defibrillator (ICD) leads. However, metallic implants usually produce artefacts on CT images which might propagate to CT-based attenuation-corrected (CTAC) PET images. The impact of metal artefact reduction (MAR) for CTAC of cardiac PET/CT images in the presence of pacemaker, ICD and ECG leads was investigated using both qualitative and quantitative analysis in phantom and clinical studies. The study included 14 patients with various leads undergoing perfusion and viability examinations using dedicated cardiac PET/CT protocols. The PET data were corrected for attenuation using both artefactual CT images and CT images corrected using the MAR algorithm. The severity and magnitude of metallic artefacts arising from these leads were assessed on both linear attenuation coefficient maps ({mu}-maps) and attenuation-corrected PET images. CT and PET emission data were obtained using an anthropomorphic thorax phantom and a dedicated heart phantom made in-house incorporating pacemaker and ICD leads attached at the right ventricle of the heart. Volume of interest-based analysis and regression plots were performed for regions related to the lead locations. Bull's eye view analysis was also performed on PET images corrected for attenuation with and without the MAR algorithm. In clinical studies, the visual assessment of PET images by experienced physicians and quantitative analysis did not reveal erroneous interpretation of the tracer distribution or significant differences when PET images were corrected for attenuation with and without MAR. In phantom studies, the mean differences between tracer uptake obtained without and with MAR were 10.16{+-}2.1% and 6.86{+-}2.1% in the segments of the heart in the vicinity of metallic ICD or pacemaker leads, and were 4.43{+-}0.5% and 2.98{+-}0.5% in segments far from the leads. Although the MAR algorithm was able to effectively improve

  16. Extended charge banking model of dual path shocks for implantable cardioverter defibrillators.

    Science.gov (United States)

    Dosdall, Derek J; Sweeney, James D

    2008-08-01

    Single path defibrillation shock methods have been improved through the use of the Charge Banking Model of defibrillation, which predicts the response of the heart to shocks as a simple resistor-capacitor (RC) circuit. While dual path defibrillation configurations have significantly reduced defibrillation thresholds, improvements to dual path defibrillation techniques have been limited to experimental observations without a practical model to aid in improving dual path defibrillation techniques. The Charge Banking Model has been extended into a new Extended Charge Banking Model of defibrillation that represents small sections of the heart as separate RC circuits, uses a weighting factor based on published defibrillation shock field gradient measures, and implements a critical mass criteria to predict the relative efficacy of single and dual path defibrillation shocks. The new model reproduced the results from several published experimental protocols that demonstrated the relative efficacy of dual path defibrillation shocks. The model predicts that time between phases or pulses of dual path defibrillation shock configurations should be minimized to maximize shock efficacy. Through this approach the Extended Charge Banking Model predictions may be used to improve dual path and multi-pulse defibrillation techniques, which have been shown experimentally to lower defibrillation thresholds substantially. The new model may be a useful tool to help in further improving dual path and multiple pulse defibrillation techniques by predicting optimal pulse durations and shock timing parameters.

  17. Novel ICD Programming and Inappropriate ICD Therapy in CRT-D Versus ICD Patients: A MADIT-RIT Sub-Study.

    Science.gov (United States)

    Kutyifa, Valentina; Daubert, James P; Schuger, Claudio; Goldenberg, Ilan; Klein, Helmut; Aktas, Mehmet K; McNitt, Scott; Stockburger, Martin; Merkely, Bela; Zareba, Wojciech; Moss, Arthur J

    2016-01-01

    The Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate therapy (MADIT-RIT) trial showed a significant reduction in inappropriate implantable cardioverter defibrillator (ICD) therapy in patients programmed to high-rate cut-off (Arm B) or delayed ventricular tachycardia therapy (Arm C), compared with conventional programming (Arm A). There is limited data on the effect of cardiac resynchronization therapy with a cardioverter defibrillator (CRT-D) on the effect of ICD programming. We aimed to elucidate the effect of CRT-D on ICD programming to reduce inappropriate ICD therapy in patients implanted with CRT-D or an ICD, enrolled in MADIT-RIT. The primary end point of this study was the first inappropriate ICD therapy. Secondary end points were inappropriate anti-tachycardia pacing and inappropriate ICD shock. The study enrolled 742 (49%) patients with an ICD and 757 (51%) patients with a CRT-D. Patients implanted with a CRT-D had 62% lower risk of inappropriate ICD therapy than those with an ICD only (hazard ratio [HR] =0.38, 95% confidence interval: 0.25-0.57; Pprogramming significantly reduced the risk of inappropriate ICD therapy compared with conventional ICD programming in ICD (HR=0.14 [B versus A]; HR=0.21 [C versus A]) and CRT-D patients (HR=0.15 [B versus A]; HR=0.23 [C versus A]; Pprogramming significantly reduces the risk of inappropriate ICD therapy in both ICD and CRT-D patients. http://clinicaltrials.gov; Unique identifier: NCT00947310. © 2016 American Heart Association, Inc.

  18. Risk of chronic anxiety in implantable defibrillator patients

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; den Broek, Krista C van; Theuns, Dominic A M J

    2011-01-01

    Little is known about the prevalence of chronic anxiety in patients with an implantable cardioverter defibrillator (ICD). In a multi-center, prospective study, we examined 1) the prevalence of chronic anxiety (i.e., patients anxious at implantation and 12 months), and 2) predictors of chronic...... anxiety....

  19. Determining the risks of magnetic resonance imaging at 1.5 tesla for patients with pacemakers and implantable cardioverter defibrillators.

    Science.gov (United States)

    Cohen, Jennifer D; Costa, Heather S; Russo, Robert J

    2012-12-01

    Conventional pacemaker and implantable cardioverter-defibrillator product labeling currently cautions against exposure to magnetic resonance imaging (MRI). However, there is a growing clinical need for MRI, without an acceptable alternative imaging modality in many patients with cardiac devices. The purpose of this study was to determine the risk of MRI at 1.5 T for patients with cardiac devices by measuring the frequency of device failures and clinically relevant device parameter changes. Data from a single-center retrospective review of 109 patients with pacemakers and implantable cardioverter-defibrillators (the MRI group) who underwent 125 clinically indicated MRI studies were compared to data from a prospective cohort of 50 patients with cardiac devices who did not undergo MRI (the control group). In the MRI group, there were no deaths, device failures requiring generator or lead replacement, induced arrhythmias, losses of capture, or electrical reset episodes. Decreases in battery voltage of ≥0.04 V occurred in 4%, pacing threshold increases of ≥0.5 V in 3%, and pacing lead impedance changes of ≥50 Ω in 6%. Although there were statistically significant differences between the MRI and control groups for the mean change in pacing lead impedance (-6.2 ± 23.9 vs 3.0 ± 22.1 Ω) and left ventricular pacing threshold (-0.1 ± 0.3 vs 0.1 ± 0.2 V), these differences were not clinically important. In conclusion, MRI in patients with cardiac devices resulted in no device or lead failures. A small number of clinically relevant changes in device parameter measurements were noted. However, these changes were similar to those in a control group of patients who did not undergo MRI. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Poor perceived social support in implantable cardioverter defibrillator (ICD) patients and their partners

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Spinder, Helle; Erdman, Ruud A M

    2009-01-01

    Social support is a known buffer of psychological distress and has also been shown to influence adverse medical outcomes.......Social support is a known buffer of psychological distress and has also been shown to influence adverse medical outcomes....

  1. Psychometric properties of HeartQoL, a core heart disease-specific health-related quality of life questionnaire, in Danish implantable cardioverter defibrillator recipients

    DEFF Research Database (Denmark)

    Zangger, Graziella; Zwisler, Ann-Dorthe; Kikkenborg Berg, Selina

    2017-01-01

    Background Patient-reported health-related quality of life is increasingly used as an outcome measure in clinical trials and as a performance measure to evaluate quality of care. The objective of this study was to assess the psychometric properties of the Danish HeartQoL questionnaire, a core heart...... disease-specific health-related quality of life questionnaire, in implantable cardioverter defibrillator recipients. Design This study involved cross-sectional and test-retest study designs. Method Implantable cardioverter defibrillator recipients in the cross-sectional study completed the Heart......QoL, the Short-Form 36 Health Survey, and the Hospital Anxiety and Depression Scale. The HeartQoL structure, construct-related validity (convergent and discriminative) and reliability (internal consistency) were assessed. HeartQoL reproducibility (test-retest) was assessed in an independent sample of implantable...

  2. Unmappable ventricular tachycardia after an old myocardial infarction. Long-term results of substrate modification in patients with an implantable cardioverter defibrillator

    OpenAIRE

    Alzand, B. S. N.; Timmermans, C. C. M. M.; Wellens, H. J. J.; Dennert, R.; Philippens, S. A. M.; Portegijs, P. J. M.; Rodriguez, LM.

    2011-01-01

    Purpose The frequent occurrence of ventricular tachycardia can create a serious problem in patients with an implantable cardioverter defibrillator. We assessed the long-term efficacy of catheter-based substrate modification using the voltage mapping technique of infarct-related ventricular tachycardia and recurrent device therapy. Methods The study population consisted of 27 consecutive patients (age 68 ± 8 years, 25 men, mean left ventricular ejection fraction 31 ± 9%) with an old myocardial...

  3. Inappropriate implantable cardioverter-defibrillator shocks in Brugada syndrome: Pattern in primary and secondary prevention

    Directory of Open Access Journals (Sweden)

    Aimé Bonny

    2017-01-01

    Conclusion: Inappropriate shock is common in Brugada syndrome during the early periods after an ICD implantation, and seems to be more likely in asymptomatic patients. This finding may warrant a review of the indications for ICD implantation, especially in the young and apparently healthy population of patients with Brugada syndrome.

  4. Quality of Life and Psychological Factors in Patients with Implantable Cardioverter Defibrillator

    Directory of Open Access Journals (Sweden)

    Akiko Suyama-Chishaki, MD PhD

    2007-01-01

    CONCLUSION: To support ICD recipients both physically and mentally, not only the cardiologists but also specialists from other fields such as psychologists and nurse specialists are needed. Ancillary care must be provided through the support team. Cardiologists who determine whether ICD implantation is required must keep in mind potential psychological sequelae.

  5. Emotional distress in partners of patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Van Den Broek, Krista C; Habibović, Mirela; Pedersen, Susanne S.

    2010-01-01

    on psychological distress in partners of ICD patients and recommendations for future research. PubMed and PsycInfo were searched in March 2010 using a priori defined search terms. This search and the additional hand search resulted in 22 studies, of which 13 were quantitative and eight qualitative. Sample sizes...... studies reported no impact of ICD shocks on distress levels or quality of life in partners. ICD indication as well as comorbid conditions, age, and the psychological profile of the partner were related to distress and quality of life. Domains of concern emerging from qualitative studies were related...... to care of the ICD patient, helplessness and uncertainties related to shocks, role changes, sexual activities, overprotectiveness, and driving. Partner levels of distress may be as high as that of ICD patients. Research with large samples is needed to further investigate the course and determinants...

  6. Combined leadless pacemaker and subcutaneous implantable defibrillator therapy: feasibility, safety, and performance

    NARCIS (Netherlands)

    Tjong, F. V. Y.; Brouwer, T. F.; Smeding, L.; Kooiman, K. M.; de Groot, J. R.; Ligon, D.; Sanghera, R.; Schalij, M. J.; Wilde, A. A. M.; Knops, R. E.

    2016-01-01

    The subcutaneous implantable cardioverter-defibrillator (S-ICD) and leadless pacemaker (LP) are evolving technologies that do not require intracardiac leads. However, interactions between these two devices are unexplored. We investigated the feasibility, safety, and performance of combined LP and

  7. Wearable cardioverter defibrillators for the prevention of sudden cardiac arrest: a health technology assessment and patient focus group study

    Directory of Open Access Journals (Sweden)

    Ettinger S

    2017-11-01

    Full Text Available Sabine Ettinger,1 Michal Stanak,1 Piotr Szymański,2 Claudia Wild,1 Romana Tandara Haček,3 Darija Erčević,3 Renata Grenković,3 Mirjana Huić3 1Ludwig Boltzmann Institute for Health Technology Assessment, Vienna, Austria; 2Institute of Cardiology, Warsaw, Poland; 3Department for Development, Research and Health Technology Assessment, Agency for Quality and Accreditation in Health Care and Social Welfare, Zagreb, Croatia Aim: To summarize the evidence on clinical effectiveness and safety of wearable cardioverter defibrillator (WCD therapy for primary and secondary prevention of sudden cardiac arrest in patients at risk. Methods: We performed a systematic literature search in databases including MEDLINE via OVID, Embase, the Cochrane Library, and CRD (DARE, NHS-EED, HTA. The evidence obtained was summarized according to GRADE methodology. A health technology assessment (HTA was conducted using the HTA Core Model® for rapid relative effectiveness assessment. Primary outcomes for the clinical effectiveness domain were all-cause and disease-specific mortality. Outcomes for the safety domain were adverse events (AEs and serious adverse events (SAEs. A focus group with cardiac disease patients was conducted to evaluate ethical, organizational, patient, social, and legal aspects of the WCD use. Results: No randomized- or non-randomized controlled trials were identified. Non-comparative studies (n=5 reported AEs including skin rash/itching (6%, false alarms (14%, and palpitations/light-headedness/fainting (9% and discontinuation due to comfort/lifestyle issues (16–22%, and SAEs including inappropriate shocks (0–2%, unsuccessful shocks (0–0.7%, and death (0–0.3%. The focus group results reported that experiencing a sense of security is crucial to patients and that the WCD is not considered an option for weeks or even months due to expected restrictions in living a “normal” life. Conclusion: The WCD appears to be relatively safe for short

  8. Diagnostic Value of MRI in Patients With Implanted Pacemakers and Implantable Cardioverter-Defibrillators Across a Cross Population: Does the Benefit Justify the Risk? A Proof of Concept Study.

    Science.gov (United States)

    Samar, Huma; Yamrozik, June A; Williams, Ronald B; Doyle, Mark; Shah, Moneal; Bonnet, Christopher A; Biederman, Robert W W

    2017-09-01

    The objective of this study was to assess the diagnostic usefulness of thoracic and nonthoracic magnetic resonance imaging (MRI) imaging in patients with implantable cardiac devices (permanent pacemaker or implantable cardioverter-defibrillators [ICDs]) to determine if there was a substantial benefit to patients with regard to diagnosis and/or management. MRI is infrequently performed on patients with conventional pacemakers or ICDs. Multiple studies have documented the safety of MRI scans in patients with implanted devices, yet the diagnostic value of this approach has not been established. Evaluation data were acquired in 136 patients with implanted cardiac devices who underwent MRIs during a 10-year period at a single institution. Specific criteria were followed for all patients to objectively define if the diagnosis by MRI enhanced patient care; 4 questions were answered after scan interpretation by both MRI technologists and MRI physicians who performed the scan. 1) Did the primary diagnosis change? 2) Did the MRI provide additional information to the existing diagnosis? 3) Was the pre-MRI (tentative) diagnosis confirmed? 4) Did patient management change? If "Yes" was answered to any of the preceding questions, the MRI scan was considered to be of value to patient diagnosis and/or therapy. In 97% (n = 132) of patients, MR added value to patient diagnosis and management. In 49% (n = 67) of patients, MRI added additional valuable information to the primary diagnosis, and in 30% (n = 41) of patients, MRI changed the principle diagnosis and subsequent management of the patient. No safety issues were encountered, and no adverse effects of undergoing the MRI scan were noted in any patient. MRI in patients with implanted pacemakers and defibrillators added value to patient diagnosis and management, which justified the risk of the procedure. Published by Elsevier Inc.

  9. Implantable cardioverter defibrillators in the context of hypertrophic cardiomyopathy: a lesson in patient autonomy.

    Science.gov (United States)

    Bray, Jonathan James Hyett; Bucciarelli-Ducci, Chiara; Stuart, Graham

    2018-02-05

    Hypertrophiccardiomyopathy (HCM) is common, whereas the decision not to have an implantable cardioverterdefibrillator (ICD) when probably falling into a 'high-risk' category is not. A solicitor aged 45 years attended the inherited cardiac conditions clinic for review of her HCM and discussion about ICD implantation for primary prevention of sudden cardiac death (SCD). Despite a predicted 7% risk of SCD within the next 5 years, according to the European Society of Cardiology endorsed HCM Risk-SCD risk stratification tool, the patient opted against implantation of an ICD and comprehensively justifies her decision. This report discusses ethical aspects of a consultation offering ICD protection against SCD in the context of HCM and emphasises the clinicians' role in respecting patient autonomy. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  10. Shock as a determinant of poor patient-centered outcomes in implantable cardioverter defibrillator patients

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Van Den Broek, Krista C; Van Den Berg, Martha

    2010-01-01

    as an outcome, and compare the influence of ICD shock with other factors (e.g., heart failure and psychological factors) as determinants of outcomes, with a view to providing recommendations for clinical practice and future research. Based on the large-scale primary and secondary prevention trials (i.e., CABG......-PATCH, CIDS, AVID, AMIOVIRT, SCD-HeFT, MADIT-II, and DEFINITE), evidence for an association between ICD shocks and quality of life is mixed, with some indication that the influence of shocks may depend largely on the interval between shocks and assessment of quality of life. In order to improve the clinical...... management of ICD patients, we need to adopt a more rigorous and standardized methodology in future studies in order to be able to draw firm conclusions about the impact of ICD shocks on individual patients. We also need to acknowledge that the impact of shocks on psychological functioning and quality...

  11. Implantable Cardioverter-defibrillator Therapy for Hypertrophic Cardiomyopathy: Usefulness in Primary and Secondary Prevention.

    Science.gov (United States)

    Sarrias, Axel; Galve, Enrique; Sabaté, Xavier; Moya, Àngel; Anguera, Ignacio; Núñez, Elaine; Villuendas, Roger; Alcalde, Óscar; García-Dorado, David

    2015-06-01

    Hypertrophic cardiomyopathy is a frequent cause of sudden death. Clinical practice guidelines indicate defibrillator implantation for primary prevention in patients with 1 or more risk factors and for secondary prevention in patients with a history of aborted sudden death or sustained ventricular arrhythmias. The aim of the present study was to analyze the follow-up of patients who received an implantable defibrillator following the current guidelines in nonreferral centers for this disease. This retrospective observational study included all patients who underwent defibrillator implantation between January 1996 and December 2012 in 3 centers in the province of Barcelona. The study included 69 patients (mean age [standard deviation], 44.8 [17] years; 79.3% men), 48 in primary prevention and 21 in secondary prevention. The mean number of risk factors per patient was 1.8 in the primary prevention group and 0.5 in the secondary prevention group (P=.029). The median follow-up duration was 40.5 months. The appropriate therapy rate was 32.7/100 patient-years in secondary prevention and 1.7/100 patient-years in primary prevention (P<.001). Overall mortality was 10.1%. Implant-related complications were experienced by 8.7% of patients, and 13% had inappropriate defibrillator discharges. In patients with a defibrillator for primary prevention, the appropriate therapy rate is extremely low, indicating the low predictive power of the current risk stratification criteria. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  12. Gender differences in psychological distress and quality of life in patients with an ICD 1-year postimplant

    NARCIS (Netherlands)

    Starrenburg, Annemieke; Pedersen, Susanne; van den Broek, K.C.; Kraaier, Karin; Scholten, Marcoen; Van der Palen, Job

    2014-01-01

    Background Gender differences in patient-reported outcomes in patients with an implantable cardioverter defibrillator (ICD) have been researched, but findings are inconclusive and mostly based on cross-sectional study designs. To gain a better insight into potential determinants of psychological

  13. Gender Differences in Psychological Distress and Quality of Life in Patients with an ICD 1-Year Postimplant

    NARCIS (Netherlands)

    Starrenburg, Annemieke H.; Pedersen, Susanne S.; van den Broek, Krista; Kraaier, Karin; Scholten, Marcoen; van der Palen, Jacobus Adrianus Maria

    2014-01-01

    Background Gender differences in patient-reported outcomes in patients with an implantable cardioverter defibrillator (ICD) have been researched, but findings are inconclusive and mostly based on cross-sectional study designs. To gain a better insight into potential determinants of psychological

  14. Sex is associated with differences in individual trajectories of change in social health after implantable cardioverter-defibrillator.

    Science.gov (United States)

    Lauck, Sandra B; Sawatzky, Richard; Johnson, Joy L; Humphries, Karin; Bennett, Matthew T; Chakrabarti, Santabhanu; Kerr, Charles R; Tung, Stanley; Yeung-Lai-Wah, John A; Ratner, Pamela A

    2015-03-01

    Social health is a dimension of quality of life, and refers to people's involvement in, and satisfaction with social roles, responsibilities, and activities. The implantable cardioverter-defibrillator is associated with changes in overall quality of life, but little is known about sex differences in individual trajectories of change in social health. We prospectively measured changes in 3 subscales of the SF-36v2 generic health questionnaire (role physical, role emotional, and social functioning), 2 Patient-Reported Outcomes Measurement Information System short forms (satisfaction with participation in social roles and satisfaction with participation in discretionary social activities), and the Florida Patient Acceptance Survey before and at 1, 2, and 6 months after implantation. Individual growth models of temporal change were estimated. The scores of the 6 indicators improved with time. The unconditional model demonstrated significant (fixed effects: Pchange in the scores of 3 of the 6 measures. Although men's mean scores exceeded women's mean scores on all indicators at baseline (range of relative mean difference: 11.0% to 17.8%), the rate of women's change resulted in a reversal in relative standing at 6 months after implantation, with the mean scores of women exceeding the men's by 4.5% to 5.6%. Men and women differed in their trajectories of change in social health, both in terms of their starting points (ie, baseline scores) and their rates of change. © 2015 American Heart Association, Inc.

  15. Radiofrequency ablation of fast ventricular tachycardia causing an ICD storm in an infant with hypertrophic cardiomyopathy.

    Science.gov (United States)

    Ergul, Yakup; Ozyilmaz, Isa; Bilici, Meki; Ozturk, Erkut; Haydin, Sertaç; Guzeltas, Alper

    2018-04-01

    An implantable cardioverter defibrillator (ICD) storm involves very frequent arrhythmia episodes and ICD shocks, and it is associated with poor short-term and long-term prognosis. Radiofrequency catheter ablation can be used as an effective rescue treatment for patients with an ICD storm. To our knowledge, this is the first report of an infant with hypertrophic cardiomyopathy presenting with an ICD storm and undergoing successful radiofrequency catheter ablation salvage treatment for the fast left posterior fascicular ventricular tachycardia. © 2017 Wiley Periodicals, Inc.

  16. Long-term survival of implantable cardioverter defibrillator recipients with end-stage renal disease

    Directory of Open Access Journals (Sweden)

    Mikhael F. El-Chami, MD, FACC, FHRS

    2017-10-01

    Conclusion: ESRD patients are at significantly increased risk of mortality as compared with a non-dialysis cohort. While the majority of these patients survive more than one year post-diagnosis, the three-year mortality is high (43%. Randomized studies addressing the benefits of ICDs in ESRD patients are needed to better define their value for primary prevention of SCD.

  17. Clinical and psychological impact of prophylactic implantable cardioverter-defibrillators in a community heart failure population.

    LENUS (Irish Health Repository)

    Arnous, S

    2012-02-01

    AIMS: ICD implantation for primary prevention of sudden cardiac death in patients with left ventricular systolic dysfunction (ejection fraction <\\/= 35%) has increased since the publication of the SCD-HEFT and MADIT-II data. The aim of this study is to examine the effectiveness and safety of prophylactic ICD use in a community heart failure population and to assess the impact on patient\\'s quality of life. METHODS AND RESULTS: Seventy-one ICDs were inserted between the years 2002 and 2006. The mean follow-up from time of insertion was 24 +\\/- 11 months. Eighteen patients (25%) had potentially life-saving therapy. Seven (10%) patients received inappropriate shocks. Complications were encountered in five patients (7%). CONCLUSION: In a community heart failure population, prophylactic ICD implantation is associated with a high incidence of life-saving therapy, a low complication rate and a high level of tolerability. These data indicate translation of clinical trial benefits to the general heart failure population.

  18. Comprehensive cardiac rehabilitation improves outcome for patients with implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Pedersen, Preben Ulrich; Zwisler, Ann-Dorthe

    2015-01-01

    year of psycho-educational follow-up focusing on modifiable factors associated with poor outcomes. Two primary outcomes, general health score (Short Form-36 (SF-36)) and peak oxygen uptake (VO2), were used. Post-hoc analyses included SF-36 and ICD therapy history.Results:Comprehensive cardiac...

  19. Long-Term Evaluation of Biotronik Linox and Linox(smart) Implantable Cardioverter Defibrillator Leads.

    Science.gov (United States)

    Good, Eric D; Cakulev, Ivan; Orlov, Michael V; Hirsh, David; Simeles, John; Mohr, Kelly; Moll, Phil; Bloom, Heather

    2016-06-01

    Expert consensus holds that post-market, systematic surveillance of ICD leads is essential to ensure confirmation of adequate lead performance. GALAXY (NCT00836589) and CELESTIAL (NCT00810264) are ongoing multicenter, prospective, non-randomized registries conducted to confirm the long-term safety and reliability of Biotronik leads. ICD and CRT-D patients are followed for Linox and Linox(smart) ICD lead performance and safety for 5 years post-implant. All procedural and system-related adverse events (AEs) were assessed at each follow-up, along with lead electrical parameters. An independent CEC of EPs adjudicated AEs to determine AE category and lead relatedness. The analysis used categories of lead observations per ISO 5841-2 (Third edition). A total of 3,933 leads were implanted in 3,840 patients (73.0% male, mean age 67.0 ± 12.2 years) at 146 US centers. The estimated cumulative survival probability was 96.3% at 5 years after implant for Linox leads and 96.6% at 4 years after implant for Linox(smart) leads. A comparison of the Linox and Linox(smart) survival functions did not find evidence of a difference (P = 0.2155). The most common AEs were oversensing (23, 0.58%), conductor fracture (14, 0.36%), failure to capture (13, 0.33%), lead dislodgement (12, 0.31%), insulation breach (10, 0.25%), and abnormal pacing impedance (8, 0.20%). Linox and Linox(smart) ICD leads are safe, reliable and infrequently associated with lead-related AEs. Additionally, estimated cumulative survival probability is clinically acceptable and well within industry standards. Ongoing data collection will confirm the longer-term safety and performance of the Linox family of ICD leads. © 2016 Wiley Periodicals, Inc.

  20. Heart failure severity, inappropriate ICD therapy, and novel ICD programming: a MADIT-RIT substudy.

    Science.gov (United States)

    Daimee, Usama A; Vermilye, Katherine; Rosero, Spencer; Schuger, Claudio D; Daubert, James P; Zareba, Wojciech; McNitt, Scott; Polonsky, Bronislava; Moss, Arthur J; Kutyifa, Valentina

    2017-12-01

    The effects of heart failure (HF) severity on risk of inappropriate implantable cardioverter-defibrillator (ICD) therapy have not been thoroughly investigated. We aimed to study the association between HF severity and inappropriate ICD therapy in MADIT-RIT. MADIT-RIT randomized 1,500 patients to three ICD programming arms: conventional (Arm A), high-rate cut-off (Arm B: ≥200 beats/min), and delayed therapy (Arm C: 60-second delay for ≥170 beats/min). We evaluated the association between New York Heart Association (NYHA) class III (n = 256) versus class I-II (n = 251) and inappropriate ICD therapy in Arm A patients with ICD-only and cardiac resynchronization therapy with defibrillator (CRT-D). We additionally assessed benefit of novel ICD programming in Arms B and C versus Arm A by NYHA classification. In Arm A, the risk of inappropriate therapy was significantly higher in those with NYHA III versus NYHA I-II for both ICD (hazard ratio [HR] = 2.55, confidence interval [CI]: 1.51-4.30, P programming significantly reduced inappropriate therapy in patients with both NYHA III (Arm B vs Arm A: HR = 0.08, P programming with high-rate cut-off or delayed detection reduces inappropriate ICD therapies in both mild and moderate HF. © 2017 Wiley Periodicals, Inc.

  1. Effects of an alert system on implantable cardioverter defibrillator-related anxiety

    DEFF Research Database (Denmark)

    Duru, Firat; Dorian, Paul; Favale, Stefano

    2010-01-01

    failing to receive needed therapy for the same reason. New devices include programmable vibrating patient notifiers (PN), which, by warning patients of a possible device dysfunction, might lower device-related anxiety. PAtient NOtifier feature for Reduction of Anxiety: a Multicentre ICD study (PANORAMIC......) is a multicentre, randomized, clinical trial designed to examine the effects of the awareness of an active vibrating alert system on device-related anxiety....

  2. Antibacterial Envelope Is Associated With Low Infection Rates After Implantable Cardioverter-Defibrillator and Cardiac Resynchronization Therapy Device Replacement: Results of the Citadel and Centurion Studies.

    Science.gov (United States)

    Henrikson, Charles A; Sohail, M Rizwan; Acosta, Helbert; Johnson, Eric E; Rosenthal, Lawrence; Pachulski, Roman; Dan, Dan; Paladino, Walter; Khairallah, Farhat S; Gleed, Kent; Hanna, Ibrahim; Cheng, Alan; Lexcen, Daniel R; Simons, Grant R

    2017-10-01

    This study sought to determine whether the nonabsorbable TYRX Antibacterial Envelope (TYRX) reduces major cardiovascular implantable electronic device (CIED) infections 12 months after implant. TYRX is a monofilament polypropylene mesh impregnated with minocycline and rifampin specifically designed to hold a CIED in place and elute antimicrobials over time. There are limited data on its ability to reduce CIED infections. We prospectively enrolled patients who underwent generator replacement with an implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy device (CRT), treated with TYRX. The primary endpoints were major CIED infection and CIED mechanical complications. Given the differences in infection rates among ICD and CRT patients, 3 different control populations were used: a published benchmark rate for ICD patients, and both site-matched and comorbidity-matched controls groups for CRT patients. Overall, a major CIED infection occurred in 5 of 1,129 patients treated with TYRX (0.4%; 95% confidence interval: 0.0% to 0.9%), significantly lower than the 12-month benchmark rate of 2.2% (p = 0.0023). Among the TYRX-treated CRT cohort, the major CIED infection rate was 0.7% compared with an infection rate of 1.0% and 1.3% (p = 0.38 and p = 0.02) in site-matched and comorbidity-matched control groups, respectively. Among the ICD group, the 12-month infection rate was 0.2% compared with the published benchmark of 2.2% (p = 0.0052). The most common CIED mechanical complication in study patients was pocket hematoma, which occurred in 18 of the 1,129 patients (1.6%; 95% confidence interval: 0.8 to 2.5), which is comparable with a published rate of 1.6%. Use of TYRX was associated with a lower major CIED infection rate. (TYRX™ Envelope for Prevention of Infection Following Replacement With a CRT or ICD; [Centurion]; NCT01043861/NCT01043705). Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights

  3. Management of radiation oncology patients with implanted cardiac pacemakers or implant able cardioverter defibrilators; Tratamiento de pacientes en radioterapia con marcapasos o desfibriladores automaticos implantables

    Energy Technology Data Exchange (ETDEWEB)

    Martin Martin, G.

    2012-07-01

    The increase in life expectancy along with the technological development in the last decades has resulted in an increase in the number of patients requiring pacemaker implants or implantable cardioverter defibrillators worldwide. An increase in the number of patients with implanted cardiac devices in radiotherapy is also expected due to the risk factors in common between heart disease and cancer. In 1994 the American Association of Physicists in Medicine (AAPM) released a report about the management of radiation oncology patients with implanted cardiac pacemakers. The addition of new technologies, both in radiotherapy units and in the manufacturing process of heart devices, has shown the need for an updated protocol for the management of these patients. In this work, the most important articles published after the report of the AAPM have been compiled, in order to analyze the effects not previously studied such as dose rate, scattered radiation, electromagnetic interference or random failures produced by neutrons and protons. Additionally, the latest recommendations given by the manufacturers have been analyzed and, finally, some indications are given as an updated guide for the management of radiation oncology patients with pacemakers or cardioverter defibrillators implanted. (Author)

  4. Performance of the 2015 International Task Force Consensus Statement Risk Stratification Algorithm for Implantable Cardioverter-Defibrillator Placement in Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy.

    Science.gov (United States)

    Orgeron, Gabriela M; Te Riele, Anneline; Tichnell, Crystal; Wang, Weijia; Murray, Brittney; Bhonsale, Aditya; Judge, Daniel P; Kamel, Ihab R; Zimmerman, Stephan L; Tandri, Harikrishna; Calkins, Hugh; James, Cynthia A

    2018-02-01

    Ventricular arrhythmias are a feared complication of arrhythmogenic right ventricular dysplasia/cardiomyopathy. In 2015, an International Task Force Consensus Statement proposed a risk stratification algorithm for implantable cardioverter-defibrillator placement in arrhythmogenic right ventricular dysplasia/cardiomyopathy. To evaluate performance of the algorithm, 365 arrhythmogenic right ventricular dysplasia/cardiomyopathy patients were classified as having a Class I, IIa, IIb, or III indication per the algorithm at baseline. Survival free from sustained ventricular arrhythmia (VT/VF) in follow-up was the primary outcome. Incidence of ventricular fibrillation/flutter cycle length the algorithm appropriately differentiated risk of VT/VF, incidence of VT/VF was underestimated (observed versus expected: 29.6 [95% confidence interval, 25.2-34.0] versus >10%/year Class I; 15.5 [confidence interval 11.1-21.6] versus 1% to 10%/year Class IIa). In addition, the algorithm did not differentiate survival free from ventricular fibrillation/flutter between Class I and IIa patients ( P =0.97) or for VT/VF in Class I and IIa primary prevention patients ( P =0.22). Adding Holter results (the algorithm differentiates arrhythmic risk well overall, it did not distinguish ventricular fibrillation/flutter risks of patients with Class I and IIa implantable cardioverter-defibrillator indications. Limited differentiation was seen for primary prevention cases. As these are vital uncertainties in clinical decision-making, refinements to the algorithm are suggested prior to implementation. © 2018 American Heart Association, Inc.

  5. [The daily experience of the patient with an implantable cardioverter defibrillator].

    Science.gov (United States)

    Palacios-Ceña, Domingo; Alonso-Blanco, Cristina; Cachón-Pérez, José Miguel; Alvarez-López, Cristina

    2010-01-01

    To describe the daily experience of patients with an automatic defibrillator (AD) implant and the adaptive changes of the patient. Qualitative and phenomenological research. Collection of data through; initially unstructured interview with half of the informants, semi-structured interviews through an open questions guide after the initial unstructured interviews and use of personal narratives of the informants. Analysis of the data using the Van Manen proposal. We analysed the interviews of 10 participants. We collected socio-demographic variables and identified the following themes, which respond to the question "How is life with an AD": It is life "with the two sides of the coin," living in constant wait and uncertainty, accepting change, developing adaptation strategies, renegotiating relationships and sexuality and it is to live transformed. The results of this study can be integrated into nurse clinical practice in areas such as valuation after discharge, changes in habits, control of treatment, notification of shocks, masking detection of symptoms and strategies that can jeopardise the bearer. Research needs to be developed that looks closer into the influence of other technological devices in people. Copyright 2009 Elsevier España, S.L. All rights reserved.

  6. Electric smog: telemetry interference between ICD and LVAD.

    Science.gov (United States)

    Duncker, David; König, Thorben; Müller-Leisse, Johanna; Michalski, Roman; Oswald, Hanno; Schmitto, Jan D; Bauersachs, Johann; Veltmann, Christian

    2017-09-01

    Electromagnetic interferences between implantable cardioverter/defibrillators (ICD) and left ventricular assist devices (LVAD) impacting telemetry have been described in previous generations of ICD as well as LVAD, but have been predominantly overcome in current ICD generations. After introduction of a new fully magnetically levitated centrifugal continuous-flow circulatory pump, we report a case of tenacious telemetry interference between the HeartMate 3 LVAD and an ICD after battery exchange to an Iforia 5. Initialization of the initial telemetry handshake was only possible using several specific maneuvers simultaneously. In order to exclude device-device interference, we suggest to place the ICD above the LVAD before implantation and to test for possible telemetry interferences.

  7. Merits and limitations of the mode switching rate stabilization pacing algorithms in the implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2001-09-01

    The 7250 Jewel AF Medtronic model of ICD is the first implantable device in which both therapies for atrial arrhythmias and pacing algorithms for atrial arrhythmia prevention are available. Feasibility of that extensive atrial arrhythmia management requires correct and synergic functioning of different algorithms to control arrhythmias. The ability of the new pacing algorithms to stabilize the atrial rate following termination of treated atrial arrhythmias was evaluated in the marker channel registration of 600 spontaneously occurring episodes in 15 patients with the Jewel AF. All patients (55+/-15 years) had structural heart disease and documented atrial and ventricular arrhythmias. Dual chamber rate stabilization pacing was present in 245 (41 %) of episodes following arrhythmia termination and was a part of the mode switching operation during which pacing was provided in the dynamic DDI mode. This algorithm could function as the atrial rate stabilization pacing only when there was a slow spontaneous atrial rhythm or in presence of atrial premature beats conducted to the ventricles with a normal AV time. In case of atrial premature beats with delayed or absent conduction to the ventricles and in case of ventricular premature beats, the algorithm stabilized the ventricular rate. The rate stabilization pacing in DDI mode during sinus rhythm following atrial arrhythmia termination was often extended in time due to the device-based definition of arrhythmia termination. This was also the case in patients, in whom the DDD mode with true atrial rate stabilization algorithm was programmed. The rate stabilization algorithms in the Jewel AF applied after atrial arrhythmia termination provide pacing that is not based on the timing of atrial events. Only under certain circumstances the algorithm can function as atrial rate stabilization pacing. Adjustments in availability and functioning of the rate stabilization algorithms might be of benefit for the clinical performance of

  8. Sexual concerns and practices after ICD implantation

    DEFF Research Database (Denmark)

    Kikkenborg Berg, Selina; Elleman-Jensen, Line; Zwisler, Ann-Dorthe

    2013-01-01

    given about sexual activity, (b) the areas of patient concerns related to sexual function and the ICD, and (c) changes in sexual behavior.Methods:A randomized controlled trial including 196 patients (1:1) was designed, including 12 weeks of exercise training and 1 year of psycho-educational follow......Background:Studies show that patients with implantable cardioverter defibrillators (ICD) frequently experience sexual dysfunction. These experiences are often linked to exercise intolerance, side-effects of medication, and psychological problems.Objective:To describe (a) the level of information......-up focusing on modifiable factors associated with poor outcomes, including sexual functioning. The Sex After ICD Survey was administered 6 months after the randomization as part of the planned explorative outcomes. 141 patients responded.Results:The analyses showed that 37 of the 69 (55.2%) patients...

  9. Statins Decrease Oxidative Stress and ICD Therapies

    Directory of Open Access Journals (Sweden)

    Heather L. Bloom

    2010-01-01

    Full Text Available Recent studies demonstrate that statins decrease ventricular arrhythmias in internal cardioverter defibrillator (ICD patients. The mechanism is unknown, but evidence links increased inflammatory and oxidative states with increased arrhythmias. We hypothesized that statin use decreases oxidation. Methods. 304 subjects with ICDs were surveyed for ventricular arrhythmia. Blood was analyzed for derivatives of reactive oxygen species (DROMs and interleukin-6 (IL-6. Results. Subjects included 252 (83% men, 58% on statins, 20% had ventricular arrhythmias. Average age was 63 years and ejection fraction (EF 20%. ICD implant duration was 29 ± 27 months. Use of statins correlated with lower ICD events (r=0.12, P=.02. Subjects on statins had lower hsCRP (5.2 versus 6.3; P=.05 and DROM levels (373 versus 397; P=.03. Other factors, including IL-6 and EF did not differ between statin and nonstatin use, nor did beta-blocker or antiarrhythmic use. Multivariate cross-correlation analysis demonstrated that DROMs, statins, IL-6 and EF were strongly associated with ICD events. Multivariate regression shows DROMs to be the dominant predictor. Conclusion. ICD event rate correlates with DROMs, a measure of lipid peroxides. Use of statins is associated with reduced DROMs and fewer ICD events, suggesting that statins exert their effect through reducing oxidation.

  10. Evaluation oF FactORs ImpacTing CLinical Outcome and Cost EffectiveneSS of the S-ICD: Design and Rationale of the EFFORTLESS S-ICD Registry

    DEFF Research Database (Denmark)

    Pedersen, Susanne S; Lambiase, Pier; Boersma, Lucas V A

    2012-01-01

    utilization. Methods: The Registry is an observational, nonrandomized, standard of care evaluation to be conducted at approximately 50 investigational centers in Europe and New Zealand where the S-ICD is approved for use and distribution. Clinical Registry endpoints include perioperative (30 days postimplant......Background: Leads in and on the heart of the transvenous implantable cardioverter defibrillator (ICD) form the Achilles' heel of this system due to potential for peri- and postimplant complications. The S-ICD is a newer generation of the ICD that does not require leads on the heart...... or in the vasculature. We present the rationale and study design of the Evaluation oF FactORs ImpacTing CLinical Outcome and Cost EffectiveneSS of the S-ICD (EFFORTLESS S-ICD) Registry which was designed to evaluate the long-term performance of the S-ICD including patient quality of life and long-term resource...

  11. Anxiety Predicts Mortality in ICD Patients

    DEFF Research Database (Denmark)

    Kikkenborg Berg, Selina; Caspar Thygesen, Lau; Hastrup Svendsen, Jesper

    2014-01-01

    BACKGROUND: Although highly effective in preventing arrhythmic death, patients receiving an implantable cardioverter defibrillator (ICD) may still experience psychological difficulties such as anxiety, depression, and reduced quality of life. The objectives of this study were to describe patient...... receiving ICD between January 1, 2011 and June 30, 2011 (n = 499). The following instruments were used: SF-36, Hospital Anxiety and Depression Scale, HeartQoL, EQ-5D, and the Multidimensional Fatigue Inventory. RESULTS: The response rate was 72%. Mean age was 65.5 years and 82% patients were males. Fifty...... of perceived health, quality of life, and fatigue; for example, physical health 39.8 versus 44.3 points, compared to secondary prevention indication. Anxiety, poor perceived health, fatigue, and low quality of life were all predictors of mortality, anxiety being the strongest with an adjusted odds ratio of 4...

  12. The natural history of new-onset heart failure with a severely depressed left ventricular ejection fraction: implications for timing of implantable cardioverter-defibrillator implantation.

    Science.gov (United States)

    Teeter, William A; Thibodeau, Jennifer T; Rao, Krishnasree; Brickner, M Elizabeth; Toto, Kathleen H; Nelson, Lauren L; Mishkin, Joseph D; Ayers, Colby R; Miller, Justin G; Mammen, Pradeep P A; Patel, Parag C; Markham, David W; Drazner, Mark H

    2012-09-01

    Guidelines recommend that patients with new-onset systolic heart failure (HF) receive a trial of medical therapy before an implantable cardiac defibrillator (ICD). This strategy allows for improvement of left ventricular ejection fraction (LVEF), thereby avoiding an ICD, but exposes patients to risk of potentially preventable sudden cardiac death during the trial of medical therapy. We reviewed a consecutive series of patients with HF of <6 months duration with a severely depressed LVEF (<30%) evaluated in a HF clinic (N = 224). The ICD implantation was delayed with plans to reassess LVEF approximately 6 months after optimization of β-blockers. Mortality was ascertained by the National Death Index. Follow-up echocardiograms were performed in 115 of the 224 subjects. Of these, 50 (43%) had mildly depressed or normal LVEF at follow-up ("LVEF recovery") such that an ICD was no longer indicated. In a conservative sensitivity analysis (using the entire study cohort, whether or not a follow-up echocardiogram was obtained, as the denominator), 22% of subjects had LVEF recovery. Mortality at 6, 12, and 18 months in the entire cohort was 2.3%, 4.5%, and 6.8%, respectively. Of 87 patients who tolerated target doses of β-blockers, only 1 (1.1%) died during the first 18 months. Patients with new-onset systolic HF have both a good chance of LVEF recovery and low 6-month mortality. Achievement of target β-blocker dose identifies a very low-risk population. These data support delaying ICD implantation for a trial of medical therapy. Copyright © 2012 Mosby, Inc. All rights reserved.

  13. Defibrillator Implantation in Patients with Nonischemic Systolic Heart Failure

    DEFF Research Database (Denmark)

    Køber, Lars; Thune, Jens J; Nielsen, Jens C

    2016-01-01

    Background The benefit of an implantable cardioverter-defibrillator (ICD) in patients with symptomatic systolic heart failure caused by coronary artery disease has been well documented. However, the evidence for a benefit of prophylactic ICDs in patients with systolic heart failure that is not due...... to coronary artery disease has been based primarily on subgroup analyses. The management of heart failure has improved since the landmark ICD trials, and many patients now receive cardiac resynchronization therapy (CRT). Methods In a randomized, controlled trial, 556 patients with symptomatic systolic heart.......6%) in the control group (P=0.29). Conclusions In this trial, prophylactic ICD implantation in patients with symptomatic systolic heart failure not caused by coronary artery disease was not associated with a significantly lower long-term rate of death from any cause than was usual clinical care. (Funded by Medtronic...

  14. Catheter ablation for the treatment of electrical storm in patients with implantable cardioverter-defibrillators: short- and long-term outcomes in a prospective single-center study.

    Science.gov (United States)

    Carbucicchio, Corrado; Santamaria, Matteo; Trevisi, Nicola; Maccabelli, Giuseppe; Giraldi, Francesco; Fassini, Gaetano; Riva, Stefania; Moltrasio, Massimo; Cireddu, Manuela; Veglia, Fabrizio; Della Bella, Paolo

    2008-01-29

    Electrical storm (ES) caused by recurrent episodes of ventricular tachycardia (VT) can cause sudden death in patients with implantable cardioverter-defibrillators and adversely affects prognosis in survivors. Catheter ablation has been proposed for treating ES, but its long-term effect in a large population has never been verified. Ninety-five consecutive patients with coronary artery disease (72 patients), idiopathic dilated cardiomyopathy (10 patients), and arrhythmogenic right ventricular dysplasia/cardiomyopathy (13 patients) undergoing catheter ablation for drug-refractory ES were prospectively evaluated. Short-term efficacy was defined by a complete protocol of programmed electric stimulation and by in-hospital outcome; long-term analysis addressed ES recurrence, cardiac mortality, and VT recurrence. Pleomorphic/nontolerated VTs required electroanatomic and noncontact mapping in 48 and 22 patients, respectively, and percutaneous cardiopulmonary support in 10 patients. An epicardial approach was used in 10 patients. After 1 to 3 procedures, induction of any clinical VT(s) by programmed electrical stimulation was prevented in 85 patients (89%). ES was acutely suppressed in all patients; a minimum period of 7 days with stable rhythm was required before hospital discharge. At a median follow-up of 22 months (range, 1 to 43 months), 87 patients (92%) were free of ES and 63 patients (66%) were free of VT recurrence. Eight of 10 patients with persistent inducibility of clinical VT(s) had ES recurrence; 4 of them died suddenly despite appropriate implantable cardioverter-defibrillator intervention. All together, 11 of 95 patients (12%) died of cardiac-related reasons. In the group of patients presenting with all clinical VTs acutely abolished, no ES recurrence was documented, and cardiac mortality was significantly lower compared with the group of patients showing > or = 1 clinical VT still inducible after catheter ablation. Advanced strategies of catheter ablation

  15. Unmappable ventricular tachycardia after an old myocardial infarction. Long-term results of substrate modification in patients with an implantable cardioverter defibrillator.

    Science.gov (United States)

    Alzand, B S N; Timmermans, C C M M; Wellens, H J J; Dennert, R; Philippens, S A M; Portegijs, P J M; Rodriguez, L M

    2011-08-01

    The frequent occurrence of ventricular tachycardia can create a serious problem in patients with an implantable cardioverter defibrillator. We assessed the long-term efficacy of catheter-based substrate modification using the voltage mapping technique of infarct-related ventricular tachycardia and recurrent device therapy. The study population consisted of 27 consecutive patients (age 68 ± 8 years, 25 men, mean left ventricular ejection fraction 31 ± 9%) with an old myocardial infarction and multiple and/or hemodynamically not tolerated ventricular tachycardia necessitating repeated device therapy. A total of 31 substrate modification procedures were performed using the three-dimensional electroanatomical mapping system. Patients were followed up for a median of 23.5 (interquartile range 6.5-53.2) months before and 37.8 (interquartile range 11.7-71.8) months after ablation. Antiarrhythmic drugs were not changed after the procedure, and were stopped 6 to 9 months after the procedure in patients who did not show ventricular tachycardia recurrence. Median ventricular tachycardias were 1.6 (interquartile range 0.7-6.7) per month before and 0.2 (interquartile range 0.00-1.3) per month after ablation (P = 0.006). Nine ventricular fibrillation episodes were registered in seven patients before and two after ablation (P = 0.025). Median antitachycardia pacing decreased from 1.6 (interquartile range 0.01-5.5) per month before to 0.18 (interquartile range 0.00-1.6) per month after ablation (P = 0.069). Median number of shocks decreased from 0.19 (interquartile range 0.04-0.81) per month before to 0.00 (interquartile range 0.00-0.09) per month after ablation (P = 0.001). One patient had a transient ischemic attack during the procedure, and another developed pericarditis. Nine patients died during follow-up, eight patients due to heart failure and one patient during valve surgery. Catheter-based substrate modification using voltage mapping results in a long-lasting reduction

  16. Towards evidence-based emergency medicine: Best BETs from the Manchester Royal Infirmary. BET 2: Is there value in testing troponin levels after ICD discharge?

    Science.gov (United States)

    Targett, Chris; Harris, Tim

    2014-03-01

    A short cut review was carried out to establish whether testing for troponin levels is useful after discharge of an Implanted Cardioverter-Defibrillator (ICD). Many papers were found using the reported searches, none of which directly addressed the problem but some 13 presented the best evidence to answer the clinical question. The author, date and country of publication, patient group studied, study type, relevant outcomes, results and study weaknesses of those best papers are tabulated. It is concluded that the number of ICD discharges must be taken into account when evaluating any troponin level rise. Overall a positive troponin assay post ICD discharge is independently associated with an increased mortality.

  17. The impact of co-morbidity burden on appropriate implantable cardioverter defibrillator therapy and all-cause mortality

    DEFF Research Database (Denmark)

    Ruwald, Anne Christine; Vinther, Michael; Gislason, Gunnar H

    2017-01-01

    -ICD indication-related co-morbidities including atrial fibrillation, diabetes, chronic obstructive pulmonary disease, chronic renal disease, liver disease, cancer, chronic psychiatric disease, and peripheral and/or cerebrovascular disease, and divided into four groups (co-morbidity burden 0, 1, 2, and ≥3......). Through Cox models, we assessed the impact of co-morbidity burden on appropriate ICD therapy and mortality. Increasing co-morbidity burden was not associated with increased risk of appropriate therapy, irrespective of implant indication [all hazard ratios (HRs) 1.0-1.4, P = NS]. Using no co...

  18. Single-Coil Defibrillator Leads Yield Satisfactory Defibrillation Safety Margin in Hypertrophic Cardiomyopathy.

    Science.gov (United States)

    Okamura, Hideo; Friedman, Paul A; Inoue, Yuko; Noda, Takashi; Aiba, Takeshi; Yasuda, Satoshi; Ogawa, Hisao; Kamakura, Shiro; Kusano, Kengo; Espinosa, Raul E

    2016-09-23

    Single-coil defibrillator leads have gained favor because of their potential ease of extraction. However, a high defibrillation threshold remains a concern in patients with hypertrophic cardiomyopathy (HCM), and in many cases, dual-coil leads have been used for this patient group. There is little data on using single-coil leads for HCM patients. We evaluated 20 patients with HCM who received an implantable cardioverter-defibrillator (ICD) on the left side in combination with a dual-coil lead. Two sets of defibrillation tests were performed in each patient, one with the superior vena cava (SVC) coil "on" and one with the SVC coil "off". ICDs were programmed to deliver 25 joules (J) for the first attempt followed by maximum energy (35 J or 40 J). Shock impedance and shock pulse width at 25 J in each setting as well as the results of the shock were analyzed. All 25-J shocks in both settings successfully terminated ventricular fibrillation. However, shock impedance and pulse width increased substantially with the SVC coil programmed "off" compared with "on" (66.4±6.1 ohm and 14.0±1.3 ms "off" vs. 41.9±5.0 ohm and 9.3±0.8 ms "on", Psatisfactory safety margin for 35-J devices. Single-coil leads appear appropriate for left-sided implantation in this patient group. (Circ J 2016; 80: 2199-2203).

  19. Arrhythmogenic Right Ventricular Cardiomyopathy: Risk Stratification and Indications for Defibrillator Therapy.

    Science.gov (United States)

    Zorzi, Alessandro; Rigato, Ilaria; Bauce, Barbara; Pilichou, Kalliopi; Basso, Cristina; Thiene, Gaetano; Iliceto, Sabino; Corrado, Domenico

    2016-06-01

    Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a genetically determined disease which predisposes to life-threatening ventricular arrhythmias. The main goal of ARVC therapy is prevention of sudden cardiac death (SCD). Implantable cardioverter defibrillator (ICD) is the most effective therapy for interruption of potentially lethal ventricular tachyarrhythmias. Despite its life-saving potential, ICD implantation is associated with a high rate of complications and significant impact on quality of life. Accurate risk stratification is needed to identify individuals who most benefit from the therapy. While there is general agreement that patients with a history of cardiac arrest or hemodynamically unstable ventricular tachycardia are at high risk of SCD and needs an ICD, indications for primary prevention remain a matter of debate. The article reviews the available scientific evidence and guidelines that may help to stratify the arrhythmic risk of ARVC patients and guide ICD implantation. Other therapeutic strategies, either alternative or additional to ICD, will be also addressed.

  20. Relation of symptomatic heart failure and psychological status to persistent depression in patients with implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Hoogwegt, Madelein T; Jordaens, Luc

    2011-01-01

    . We examined the prevalence and correlates of persistent depression using an intraindividual approach. Consecutive patients who had undergone ICD implantation (n = 386; 79.3% men) completed a set of validated questionnaires, including the Hospital Anxiety and Depression Scale (HADS), at baseline and 3...... months after implantation. Information on ICD therapies was obtained by device interrogation. At 3 months after implantation, 52 (14%) of the 386 patients had persistent depression (HADS cutoff ≥8 before and 3 months after implantation). Heart failure (odds ratio [OR] 2.29; 95% confidence interval [CI] 1.......71), diuretics (OR 2.41; 95% CI 1.26 to 4.61), and psychotropic medication (OR 3.58; 95% CI 1.86 to 6.90) were all significant univariate correlates of persistent depression at 3 months. No effect was found for ICD shock during follow-up (OR 1.59; 95% CI 0.57 to 4.41). In adjusted analysis, New York Heart...

  1. Combined etiology of anaphylactic cardiogenic shock: Amiodarone, epinephrine, cardioverter defibrillator, left ventricular assist devices and the Kounis syndrome

    Directory of Open Access Journals (Sweden)

    Nicholas G Kounis

    2015-01-01

    Full Text Available Anaphylactic shock is a life-threatening condition which needs detailed and mediculous clinical assessment and thoughtful treatment. Several causes can join forces in order to degranulate mast cells. Amiodarone which is an iodine-containing highly lipophilic benzofuran can induce allergic reactions and anaphylactic shock in sensitized patients. Epinephrine is a life saving drug, but in sulfite allergic patients it should be given with caution due its metabisulfite preservative. Metals covering cardiac defibrillators and pacemakers can act as antigens attached to serum proteins and induce allergic reactions. In anaphylactic shock, myocardial involvement due to vasospasm-induced coronary blood flow reduction manifesting as Kounis syndrome should be always considered. Clinically, combined treatment targeting the primary cause of anaphylaxis together with protection of cardiac tissue seems to be of paramount importance.

  2. A Pregnancy with Severe Hypertrophic Obstructive Cardiomyopathy after Surgery for an Implantable Cardioverter Defibrillator: A Case Report and Literature Review

    Directory of Open Access Journals (Sweden)

    Takashi Mitsui

    2016-01-01

    Full Text Available Hypertrophic obstructive cardiomyopathy (HOCM is cardiac hypertrophy of ventricular myocardium with left ventricular outflow tract obstruction. We report a pregnancy with HOCM after defibrillator implantation surgery. The patient was a 33-year-old nulligravida and was categorized as New York Heart Association class II. Her brain natriuretic peptide (BNP level was 724.6 pg/dL at preconception. She received careful pregnancy management. However, because frequent uterine contractions were observed at 25 weeks and 6 days of pregnancy, she was hospitalized, and magnesium sulfate was started as a tocolytic agent. At 27 weeks and 5 days of pregnancy, she had respiratory discomfort and orthopnea with a sudden decrease in peripheral oxygen saturation. Cardiac ultrasonography showed a worsened condition of HOCM and her BNP level was 1418.0 pg/mL. We performed an emergent cesarean section and she delivered a boy weighing 999 g. The Apgar score was 8 and 9 points at 1 and 5 minutes, respectively. The mother’s heart failure quickly improved after birth and she was discharged at 10 days postoperatively. Fluctuations in circulatory dynamics during pregnancy may sometimes exacerbate heart disease. Therefore, the risks should be fully explained and careful assessment of cardiac function should be performed during pregnancy in patients with severe HOCM.

  3. An eight-year prospective controlled study about the safety and diagnostic value of cardiac and non-cardiac 1.5-T MRI in patients with a conventional pacemaker or a conventional implantable cardioverter defibrillator.

    Science.gov (United States)

    Lupo, Pierpaolo; Cappato, Riccardo; Di Leo, Giovanni; Secchi, Francesco; Papini, Giacomo D E; Foresti, Sara; Ali, Hussam; De Ambroggi, Guido M G; Sorgente, Antonio; Epicoco, Gianluca; Cannaò, Paola M; Sardanelli, Francesco

    2018-06-01

    To investigate safety and diagnostic value of 1.5-T MRI in carriers of conventional pacemaker (cPM) or conventional implantable defibrillator (cICD). We prospectively compared cPM/cICD-carriers undergoing MRI (study group, SG), excluding those device-dependent or implanted cPM/cICD-carriers undergoing chest x-ray, CT or follow-up (reference group, RG). 142 MRI (55 cardiac) were performed in 120 patients with cPM (n=71) or cICD (n=71). In the RG 98 measurements were performed in 95 patients with cPM (n=40) or cICD (n=58). No adverse events were observed. No MRI prolonged/interrupted. All cPM/cICD were correctly reprogrammed after MRI without malfunctions. One temporary communication failure was observed in one cPM-carrier. Immediately after MRI, 12/14 device interrogation parameters did not change significantly (clinically negligible changes of battery voltage and cICD charging time), without significant variations for SG versus RG. Three-12 months after MRI, 9/11 device interrogation parameters did not change significantly (clinically negligible changes of battery impedance/voltage). Non-significant changes of three markers of myocardial necrosis. Non-cardiac MRI: 82/87 diagnostic without artefacts; 4/87 diagnostic with artefacts; 1/87 partially diagnostic. Cardiac MRI: in cPM-carriers, 14/15 diagnostic with artefacts, 1/15 partially diagnostic; in cICD-carriers, 9/40 diagnostic with artefacts, 22 partially diagnostic, nine non-diagnostic. A favourable risk-benefit ratio of 1.5-T MRI in cPM/cICD carriers was reported. • Cooperation between radiologists and cardiac electrophysiologists allowed safe 1.5-T MRI in cPM/cICD-carriers. • No adverse events for 142 MRI in 71 cPM-carriers and 71 cICD-carriers. • Ninety-nine per cent (86/87) of non-cardiac MRI in cPM/cICD-carriers were diagnostic. • All cPM-carrier cardiac MRIs had artefacts, 14 examinations diagnostic, 1 partially diagnostic. • Twenty-three per cent (9/40) of cardiac MRI in cICD-carriers were non-diagnostic.

  4. [Restrictions for ICD patients in daily life].

    Science.gov (United States)

    Köbe, Julia; Gradaus, Rainer; Zumhagen, Sven; Böcker, Dirk

    2005-11-01

    Patients with an implantable cardioverter defibrillator (ICD) may experience loss of consciousness. Electromagnetic interference (EMI) may trigger undesired or inhibit necessary therapy in patients with an ICD. Therefore, questions about personal or professional activities for ICD patients arise. Restricting driving or other personal activities has adverse effects on the patient's quality of life. The national Societies of Cardiology provide recommendations for ICD patients concerning driving of motor vehicles. Patients with an ICD that is implanted prophylactically do not have to refrain from driving after recovery from the implantation procedure. Patients with arrhythmias are classified into different groups depending on the risk of recurrence of tachycardias and symptoms. Commercial driving is not allowed for patients with an ICD in Germany except for those with a prophylactic indication without a history of arrhythmias. Those patients may drive small cars but no trucks or busses. Guidelines for medical fitness in commercial or military flying are regulated by the Joint Aviation Authorities (JAA) and ventricular tachycardias are a contraindication for both. Fortunately, loss of consciousness is not dangerous in most jobs. Strong sources of EMI can occur at special workplaces. Patients have to be advised and tested individually concerning their risk for EMI at their employment site before returning safely. Modern life exposes to an increasing amount of EMI. Intact household devices usually do not interfere with ICDs. Mobile phones may interfere with implanted devices. Interaction can be minimized by special precautions like maintaining a distance of minimum 10 cm between mobile phone and ICD. Electronic surveillance systems work differently and have the potential to interact with devices. Patients should be advised to pass those systems with avoiding longer exposure. The presence of an ICD is presently a contraindication for undergoing magnetic resonance imaging

  5. Economic impact of longer battery life of cardiac resynchronization therapy defibrillators in Sweden

    Directory of Open Access Journals (Sweden)

    Gadler F

    2016-10-01

    Full Text Available Fredrik Gadler,1 Yao Ding,2 Nathalie Verin,3 Martin Bergius,4 Jeffrey D Miller,5 Gregory M Lenhart,5 Mason W Russell5 1Department of Cardiology, Karolinska University Hospital, Stockholm, Sweden; 2Truven Health Analytics, an IBM Company, Bethesda, MD, USA; 3Boston Scientific Corporation, Hemel Hempstead, Hertfordshire, UK; 4Boston Scientific Nordic AB, Helsingborg, Sweden; 5Truven Health Analytics, an IBM Company, Cambridge, MA, USA Objective: The objective of this study was to quantify the impact that longer battery life of cardiac resynchronization therapy defibrillator (CRT-D devices has on reducing the number of device replacements and associated costs of these replacements from a Swedish health care system perspective.Methods: An economic model based on real-world published data was developed to estimate cost savings and avoided device replacements for CRT-Ds with longer battery life compared with devices with industry-standard battery life expectancy. Base-case comparisons were performed among CRT-Ds of three manufacturers – Boston Scientific Corporation, St. Jude Medical, and Medtronic – over a 6-year time horizon, as per the available clinical data. As a sensitivity analysis, we evaluated CRT-Ds as well as single-chamber implantable cardioverter defibrillator (ICD-VR and dual-chamber implantable cardioverter defibrillator (ICD-DR devices over a longer 10-year period. All costs were in 2015 Swedish Krona (SEK discounted at 3% per annum.Results: Base-case analysis results show that up to 603 replacements and up to SEK 60.4 million cumulative-associated costs could be avoided over 6 years by using devices with extended ­battery life. The pattern of savings over time suggests that savings are modest initially but increase rapidly beginning in the third year of follow-up with each year’s cumulative savings two to three times the previous year. Evaluating CRT-D, ICD-VR, and ICD-DR devices together over a longer 10-year period, the

  6. Acute evaluation of transthoracic impedance vectors using ICD leads.

    Science.gov (United States)

    Gottfridsson, Christer; Daum, Douglas; Kennergren, Charles; Ramuzat, Agnès; Willems, Roger; Edvardsson, Nils

    2009-06-01

    Minute ventilation (MV) has been proven to be very useful in rate responsive pacing. The aim of this study was to evaluate the feasibility of using implantable cardioverter-defibrillator (ICD) leads as part of the MV detection system. At implant in 10 patients, the transthoracic impedance was measured from tripolar ICD, tetrapolar ICD, and atrial lead vectors during normal, deep, and shallow voluntary respiration. MV and respiration rate (RespR) were simultaneously measured through a facemask with a pneumotachometer (Korr), and the correlations with impedance-based measurements were calculated. Air sensitivity was the change in impedance per change in respiratory tidal volume, ohms (Omega)/liter (L), and the signal-to-noise ratio (SNR) was the ratio of the respiratory and cardiac contraction components. The air sensitivity and SNR in tripolar ICD vector were 2.70 +/- 2.73 ohm/L and 2.19 +/- 1.31, respectively, and were not different from tetrapolar. The difference in RespR between tripolar ICD and Korr was 0.2 +/- 1.91 breaths/minute. The regressed correlation coefficient between impedance MV and Korr MV was 0.86 +/- 0.07 in tripolar ICD. The air sensitivity and SNR in tripolar and tetrapolar ICD lead vectors did not differ significantly and were in the range of the values in pacemaker leads currently used as MV sensors. The good correlations between impedance-based and Korr-based RespR and MV measurements imply that ICD leads may be used in MV sensor systems.

  7. Subcutaneous Implantable Cardioverter-Defibrillator

    Science.gov (United States)

    ... discriminator functions and lacks antitachycardia pacing. Expanded Programmability Programming that allows lower shock energies and the ability ... 2014 American Heart Association, Inc. References 1. ↵ Weiss R , Knight BP , Gold MR , Leon AR , Herre JM , ...

  8. Postmortem ICD interrogation in mode of death classification.

    Science.gov (United States)

    Nikolaidou, Theodora; Johnson, Miriam J; Ghosh, Justin M; Marincowitz, Carl; Shah, Saumil; Lammiman, Michael J; Schilling, Richard J; Clark, Andrew L

    2018-04-01

    The definition of sudden death due to arrhythmia relies on the time interval between onset of symptoms and death. However, not all sudden deaths are due to arrhythmia. In patients with an implantable cardioverter defibrillator (ICD), postmortem device interrogation may help better distinguish the mode of death compared to a time-based definition alone. This study aims to assess the proportion of "sudden" cardiac deaths in patients with an ICD that have confirmed arrhythmia. We conducted a literature search for studies using postmortem ICD interrogation and a time-based classification of the mode of death. A modified QUADAS-2 checklist was used to assess risk of bias in individual studies. Outcome data were pooled where sufficient data were available. Our search identified 22 studies undertaken between 1982 and 2015 with 23,600 participants. The pooled results (excluding studies with high risk of bias) suggest that ventricular arrhythmias are present at the time of death in 76% of "sudden" deaths (95% confidence interval [CI] 67-85; range 42-88). Postmortem ICD interrogation identifies 24% of "sudden" deaths to be nonarrhythmic. Postmortem device interrogation should be considered in all cases of unexplained sudden cardiac death. © 2018 Wiley Periodicals, Inc.

  9. Physicians’ knowledge and attitudes in Saudi Arabia regarding implantable cardiac defibrillators

    Directory of Open Access Journals (Sweden)

    Tariq Alhogbani

    2018-04-01

    Full Text Available Objectives: To evaluate knowledge and attitude of physicians involved in the management of patients with heart failure regarding implantable cardioverter-defibrillator (ICD. Methods: We conducted personal interviews with physicians involved in treating patients with heart failure. Between October 2015 and February 2016, the study was conducted in hospitals in the Riyadh region where no cardiac electrophysiology service was available. Every participant was met in person and received an oral questionnaire that aimed to assess basic knowledge regarding ICD indications and benefits. Results: Sixty-three physicians were met from 13 hospitals (14 consultants and 49 specialists. Forty-one percent of participants use the recommended cut-off level of left ventricular ejection fraction (LVEF which is ≤35% as the LVEF criterion for ICD referral in patients with cardiomyopathy. Only 50% of the consultants use ≤35% as the LVEF criterion for ICD referral. Seventy percent of the participants thought that ICD may improve heart failure symptoms. Forty-eight percent of physicians have a defined channel to refer patients to higher centers for ICD implant. There was no statistically significant difference between physicians’ knowledge when we categorized them according to three different factors: (1 physician’s specialty (cardiology vs. internal medicine; (2 physician’s degree (consultant vs. specialist; and (3 physician’s location (inside vs. outside Riyadh city. Conclusion: There is a lack of knowledge of current clinical guidelines regarding ICD implantation for patients with heart failure at general hospitals in Saudi Arabia. This finding highlights the need to improve the dissemination of guidelines to practitioners involved in managing patients with heart failure in an effort to improve ICD utilization. Keywords: Cardiac defibrillator, Heart failure, Physicians’ knowledge, Saudi Arabia

  10. A prospective study of anxiety in ICD patients with a pilot randomized controlled trial of cognitive behavioral therapy for patients with moderate to severe anxiety

    DEFF Research Database (Denmark)

    Qintar, Mohammed; George, Jason J; Panko, Melanie

    2015-01-01

    , but higher anxiety was associated with recent and total number of shocks. The small pilot study suggested that a simple program of CBT might lower moderate-high anxiety with lasting effects to 1 year and supports the need for a larger trial to validate these results. CLINICAL TRIAL REGISTRATION: Clinical......PURPOSE: Stress and anxiety are potential consequences from arrhythmias and implantable cardioverter defibrillator (ICD) shocks that can contribute to substantial morbidity. We assessed anxiety associated with an ICD and whether cognitive behavioral therapy (CBT) reduces anxiety. METHODS: The study...... consisted of two parts: part 1 (N = 690) was a prospective cross-sectional observational study of consecutive ICD patients. Patients completed the Beck Anxiety Inventory (BAI), Generalized Anxiety Disorder Scale (GAD-7), Florida Shock Anxiety Scale (FSAS), and Florida Patient Acceptance Survey (FPAS...

  11. Atrial therapies reduce atrial arrhythmia burden in defibrillator patients.

    Science.gov (United States)

    Friedman, P A; Dijkman, B; Warman, E N; Xia, H A; Mehra, R; Stanton, M S; Hammill, S C

    2001-08-28

    Approximately 25% of patients who receive an implantable cardioverter-defibrillator (ICD) to treat ventricular tachyarrhythmias have documented atrial tachyarrhythmias before implantation. This study assessed the ability of device-based prevention and termination therapies to reduce the burden of spontaneous atrial tachyarrhythmias. Patients with a standard indication for the implantation of an ICD and 2 episodes of atrial tachyarrhythmias in the preceding year received a dual-chamber ICD (Medtronic 7250 Jewel AF) that uses pacing and shock therapies for prevention and/or termination of atrial tachyarrhythmias. In a multicenter trial, patients were randomized to 3-month periods with atrial therapies "on" or "off" and subsequently crossed over. Analysis was performed on the 52 of 269 patients who had episodes of atrial tachyarrhythmia and had >/=30 days of follow-up with atrial therapies on and off. The atrial therapies resulted in a reduction of atrial tachyarrhythmia burden from a mean of 58.5 to 7.8 h/mo. A paired analysis (Wilcoxon signed-rank test) showed that the median difference in burden (1.1 h/mo) was highly significant (P=0.007). When the subgroup of 41 patients treated only with atrial pacing therapies was analyzed, the reduction in burden persisted (P=0.01). In this study, patients with a standard ICD indication and atrial tachyarrhythmias had a significant reduction in atrial tachyarrhythmia burden with use of atrial pacing and shock therapies.

  12. Inverse Relation between Condition of Heart Failure and Intrathoracic Impedance Measured by Implantable Cardioverter Defibrillator—A case report—

    Directory of Open Access Journals (Sweden)

    Kohei Matsushita, MD

    2005-01-01

    Full Text Available The patient was a 78-year-old man with dilated cardiomyopathy. His cardio-thoracic ratio was 60.4% and left ventricular ejection fraction (LVEF was 33%. He had been repeatedly admitted for congestive heart failure. He underwent implantation of an implantable cardioverter-defibrillator (ICD for ventricular fibrillation. We compared the values of BNP and shock impedance stored by the ICD. The correlation coefficient (p-value between BNP and shock impedance was −0.700 (p < 0.0005, increase of BNP and shock impedance was −0.778 (p < 0.0001, percent increase of BNP and shock impedance was −0.767 (p < 0.0005. In conclusion, there is an inverse relation between BNP and shock impedance, and measurements of shock impedance may be useful in the management of congestive heart failure.

  13. Reduction in depressive symptoms in primary prevention ICD scheduled patients - One year prospective study.

    Science.gov (United States)

    Amiaz, Revital; Asher, Elad; Rozen, Guy; Czerniak, Efrat; Levi, Linda; Weiser, Mark; Glikson, Michael

    2017-09-01

    Implantable Cardioverter Defibrillators (ICDs), have previously been associated with the onset of depression and anxiety. The aim of this one-year prospective study was to evaluate the rate of new onset psychopathological symptoms after elective ICD implantation. A total of 158 consecutive outpatients who were scheduled for an elective ICD implantation were diagnosed and screened based on the Mini International Neuropsychiatric Interview (MINI). Depression and anxiety were evaluated using the Hamilton Rating Scales for Depression (HAM-D) and Anxiety (HAM-A). Patient's attitude toward the ICD device was evaluated using a Visual Analog Scale (VAS). Patients' mean age was 64±12.4years; 134 (85%) were men, with the majority of patients performing the procedure for reasons of 'primary prevention'. According to the MINI diagnosis at baseline, three (2%) patients suffered from major depressive disorder and ten (6%) from dysthymia. Significant improvement in HAM-D mean scores was found between baseline, three months and one year after implantation (6.50±6.4; 4.10±5.3 and 2.7±4.6, respectively F(2100)=16.42; pdepressive symptoms, while the overall mindset toward the ICD device was positive and improved during the one-year follow-up. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Physical activity in primary versus secondary prevention indication implantable cardioverter defibrillator recipients 6-12 months after implantation - a cross-sectional study with register follow up

    DEFF Research Database (Denmark)

    Berg, S. K.; Thygesen, L. C.; Svendsen, J. H.

    2015-01-01

    OBJECTIVE: To describe (i) physical activity status among ICD patients according to the indication for ICD implant compared to international guidelines and compared to a matched normal population in order to detect potentials for improved physical outcomes, (ii) patients' beliefs regarding...... and participation in physical exercise by ICD indication, (iii) factors predicting low physical activity, and (iv) physical activity as a predictor of mortality. DESIGN: National survey with register follow-up. Comparisons were made to a matched healthy reference population and patients were followed in registers...... MEASURES: Questions regarding physical activity and the IPAQ questionnaire were used to assess physical activity. RESULTS: The response rate was 71.7%. Mean age 65.5 years with 82% males. 37% participated in a rehabilitation programme. 21 % were sedentary compared to 8 % in the reference population (p

  15. Generator replacement is associated with an increased rate of ICD lead alerts.

    Science.gov (United States)

    Lovelock, Joshua D; Cruz, Cesar; Hoskins, Michael H; Jones, Paul; El-Chami, Mikhael F; Lloyd, Michael S; Leon, Angel; DeLurgio, David B; Langberg, Jonathan J

    2014-10-01

    Lead malfunction is an important cause of morbidity and mortality in patients with an implantable cardioverter-defibrillator (ICD). We have shown that the failure of recalled high-voltage leads significantly increases after ICD generator replacement. However, generator replacement has not been recognized as a predictor of lead failure in general. The purpose of this study is to assess the effect of ICD generator exchange on the rate of ICD lead alerts. A time-dependent Cox proportional hazards model was used to analyze a database of remotely monitored ICDs. The model assessed the impact of generator exchange on the rate of lead alerts after ICD generator replacement. The analysis included 60,219 patients followed for 37 ± 19 months. The 5-year lead survival was 99.3% (95% confidence interval 99.2%-99.4%). Of 60,219 patients, 7458 patients (12.9%) underwent ICD generator exchange without lead replacement. After generator replacement, the rate of lead alerts was more than 5-fold higher than in controls with leads of the same age without generator replacement (hazard ratio 5.19; 95% confidence interval 3.45-7.84). A large number of lead alerted within 3 months of generator replacement. Lead alerts were more common in patients with single- vs dual-chamber ICDs and in younger patients. Sex was not associated with lead alerts. Routine generator replacement is associated with a 5-fold higher risk of lead alert compared to age-matched leads without generator replacement. This suggests the need for intense surveillance after generator replacement and the development of techniques to minimize the risk of lead damage during generator replacement. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  16. Determinants of geographic variations in implantation of cardiac defibrillators in the European Society of Cardiology member countries--data from the European Heart Rhythm Association White Book.

    Science.gov (United States)

    Lubinski, Andrzej; Bissinger, Andrzej; Boersma, Lucas; Leenhardt, Antoine; Merkely, Bela; Oto, Ali; Proclemer, Alessandro; Brugada, Josep; Vardas, Panos E; Wolpert, Christian

    2011-05-01

    Sudden cardiac death (SCD) is a major health concern in developed countries. Many studies have demonstrated the efficacy of implantable cardioverter defibrillator (ICD) therapy in the prevention of SCD and total mortality reduction. However, the high individual costs and the reimbursement policy may limit widespread ICD utilization. This study analyzed the temporal and the geographical trends of the ICD implantation rate. Data were gathered from two editions of the European Heart Rhythm Association (EHRA) White Books published in 2008 and 2009. The analysis revealed significant differences in the rates of ICD implantation per million capita between the countries, but the median implantations was constantly increasing. The number of ICD implantations correlated with gross domestic product (GDP), GDP per capita, expenditure on health, life expectancy, and the number of implanting centres. There are great number of differences in the ICD-implanting rates between EHRA member countries, consequent to the increase in the number of ICD implantations. The ICD implantation rates are related to national economic status and healthcare expenses.

  17. Elektrokirurgi hos patienter med pacemaker og implanterbar kardioverter-defibrillator

    DEFF Research Database (Denmark)

    Lønnberg, Ann Sophie Claire; Philberts, Berit Thornvig; Bonde, Christian

    2017-01-01

    Electrosurgery is a very useful tool and one of the most commonly used techniques. However, the technique can interfere with pacemakers and implantable cardioverter defibrillators. This article provides practical recommendations for the use of electrosurgery in these patients.......Electrosurgery is a very useful tool and one of the most commonly used techniques. However, the technique can interfere with pacemakers and implantable cardioverter defibrillators. This article provides practical recommendations for the use of electrosurgery in these patients....

  18. Long-term single-center experience of defibrillator therapy in children and adolescents.

    Science.gov (United States)

    Frommeyer, Gerrit; Feder, Sebastian; Bettin, Markus; Debus, Volker; Köbe, Julia; Reinke, Florian; Uebing, Anselm; Eckardt, Lars; Kehl, Hans Gerd

    2018-06-01

    Implantable cardioverter-defibrillator (ICD) systems are established therapy for prevention of sudden cardiac death. Long-term data on ICD systems in children and adolescents is rare. The present study displays a long-term single-center follow-up of children and adolescents with ICD systems. The present study represents a single-center experience of patients younger than 18 years who received an ICD (n = 58). Follow-up data included in-house follow-up as well as examinations of collaborating specialists. Mean age at implantation was 14.0 ± 3.3 years and 33 patients (56.9%) were male. A transvenous ICD system was implanted in 54 patients (93.1%). In 33 patients (56.9%) electrical heart disease or idiopathic ventricular fibrillation represented the underlying condition of ICD implantation. Median follow-up duration was 70 months (45; 94). 3 patients (5.2%) died during the observation period. None of these deaths was associated with ICD failure. Appropriate shocks occurred in 32 patients (55.2%). Inappropriate shock delivery was recorded in 17 patients (29.3%). Supraventricular tachycardia represented the most frequent cause of inappropriate shock delivery (9 patients, 52.9%). T-wave oversensing led to inappropriate shock delivery in 3 patients (17.6%). In 5 patients (29.4%), lead failure caused inappropriate shock delivery. Of note, during follow-up lead failure was reported in 15 patients (25.9%) leading to surgical revision. ICD therapy in children and adolescents is effective for prevention of sudden cardiac death. The rate of appropriate shock deliveries was significantly higher as compared with large ICD trials. Inappropriate therapies occurred frequently. In particular supraventricular tachycardia, T-wave oversensing and lead failures were responsible for these episodes. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Dual- vs. single-chamber defibrillators for primary prevention of sudden cardiac death: long-term follow-up of the Défibrillateur Automatique Implantable-Prévention Primaire registry.

    Science.gov (United States)

    Defaye, Pascal; Boveda, Serge; Klug, Didier; Beganton, Frankie; Piot, Olivier; Narayanan, Kumar; Périer, Marie-Cécile; Gras, Daniel; Fauchier, Laurent; Bordachar, Pierre; Algalarrondo, Vincent; Babuty, Dominique; Deharo, Jean-Claude; Leclercq, Christophe; Marijon, Eloi; Sadoul, Nicolas

    2017-09-01

    Implantable cardioverter defibrillators (ICDs) are an effective primary prevention of sudden cardiac death. We examined whether dual-chamber (DC) ICDs confer a greater benefit than single-chamber (SC) ICDs, and compared the long-term outcomes of recipients of each type of device implanted for primary prevention. Between 2002 and 2012, the DAI-PP registry consecutively enrolled 1258 SC- and 1280 DC-ICD recipients at 12 French medical centres. The devices were interrogated at 4- to 6-month intervals during outpatient visits, with a focus on the therapies delivered. The study endpoints were incidence of appropriate therapies, ICD-related morbidity, and deaths from all and from specific causes. The mean age of the SC- and DC-ICD recipients was 59 ± 12 and 62 ± 11 years, respectively (PDC- vs. 8.8% in the SC-ICD groups (P= 0.008). Over a mean follow-up of 3.1 ± 2.2 years, pulse generators were replaced in 21.9% of the DC- vs. 13.6% of the SC-ICD group (PDC-ICDs were associated with higher rates of peri-implant complications and generator replacements, whereas the survival and rates of inappropriate shocks were similar in both groups. NCT#01992458. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions please email: journals.permissions@oup.com.

  20. Electrical storm is an independent predictor of adverse long-term outcome in the era of implantable defibrillator therapy.

    Science.gov (United States)

    Gatzoulis, Konstantinos A; Andrikopoulos, George K; Apostolopoulos, Theodoros; Sotiropoulos, Elias; Zervopoulos, George; Antoniou, John; Brili, Stella; Stefanadis, Christodoulos I

    2005-03-01

    Electrical storm (ES) is a life-threatening arrhythmia complication affecting patients treated with an implantable cardioverter defibrillator (ICD). Despite its increasing importance, existing data on prognosis and management of ICD patients affected by ES are limited and conflicting. We prospectively studied 169 consecutive patients receiving an ICD. Thirty-two patients presented with at least one episode of ES during the period of observation (33+/-26 months). ES patients were older (64+/-9 vs. 59+/-13 years, P=0.013) with more advanced congestive heart failure (CHF) but a similar incidence of an underlying organic heart disease. Long-term total and cardiac mortality were both increased among ES patients. Seventeen of the 32 ES patients died as opposed to 19 of the 137 ICD patients without ES (53 vs. 14%, P<0.001). In multivariate Cox regression analysis adjusted for the main confounders, history of ES was significantly and independently associated with total and cardiac mortality (risk ratio (RR)=2.13, P=0.031 and RR=2.59, P=0.019, respectively). ES is a relatively frequent complication affecting ICD patients treated for secondary prevention of sudden cardiac death (SCD). Although the acute management of this serious arrhythmia complication is usually successful, occurrence of ES is a strong independent predictor of poor outcome in ICD patients.

  1. Short- and long-term performance of a tripolar down-sized single lead for implantable cardioverter defibrillator treatment: a randomized prospective European multicenter study. European Endotak DSP Investigator Group.

    Science.gov (United States)

    Sandstedt, B; Kennergren, C; Schaumann, A; Herse, B; Neuzner, J

    1998-11-01

    A new, thinner (10 Fr) and more flexible, single-pass transvenous endocardial ICD lead, Endotak DSP, was compared with a conventional lead, Endotak C, as a control in a prospective randomized multicenter study in combination with a nonactive can ICD. A total of 123 patients were enrolled, 55 of whom received a down-sized DSP lead. Lead-alone configuration was successfully implanted in 95% of the DSP patients vs 88% in the control group. The mean defibrillation threshold (DFT) was determined by means of a step-down protocol, and was identical in the two groups, 10.5 +/- 4.8 J in the DSP group versus 10.5 +/- 4.8 J in the control group. At implantation, the DSP mean pacing threshold was lower, 0.51 +/- 0.18 V versus 0.62 +/- 0.35 V (p < 0.05) in the control group, and the mean pacing impedance higher, 594 +/- 110 omega vs 523 +/- 135 omega (p < 0.05). During the follow-up period, the statistically significant difference in thresholds disappeared, while the difference in impedance remained. Tachyarrhythmia treatment by shock or antitachycardia pacing (ATP) was delivered in 53% and 41%, respectively, of the patients with a 100% success rate. In the DSP group, all 28 episodes of polymorphic ventricular tachycardia or ventricular fibrillation were converted by the first shock as compared to 57 of 69 episodes (83%) in the control group (p < 0.05). Monomorphic ventricular tachycardias were terminated by ATP alone in 96% versus 94%. Lead related problems were minor and observed in 5% and 7%, respectively. In summary, both leads were safe and efficacious in the detection and treatment of ventricular tachyarrhythmias. There were no differences between the DSP and control groups regarding short- or long-term lead related complications.

  2. Subcutaneous ICD screening with the Boston Scientific ZOOM programmer versus a 12-lead ECG machine.

    Science.gov (United States)

    Chang, Shu C; Patton, Kristen K; Robinson, Melissa R; Poole, Jeanne E; Prutkin, Jordan M

    2018-02-24

    The subcutaneous implantable cardioverter-defibrillator (S-ICD) requires preimplant screening to ensure appropriate sensing and reduce risk of inappropriate shocks. Screening can be performed using either an ICD programmer or a 12-lead electrocardiogram (ECG) machine. It is unclear whether differences in signal filtering and digital sampling change the screening success rate. Subjects were recruited if they had a transvenous single-lead ICD without pacing requirements or were candidates for a new ICD. Screening was performed using both a Boston Scientific ZOOM programmer (Marlborough, MA, USA) and General Electric MAC 5000 ECG machine (Fairfield, CT, USA). A pass was defined as having at least one lead that fit within the screening template in both supine and sitting positions. A total of 69 subjects were included and 27 sets of ECG leads had differing screening results between the two machines (7%). Of these sets, 22 (81%) passed using the ECG machine but failed using the programmer and five (19%) passed using the ECG machine but failed using the programmer (P machine but failed using the programmer. No subject passed screening with the programmer but failed with the ECG machine. There can be occasional disagreement in S-ICD patient screening between an ICD programmer and ECG machine, all of whom passed with the ECG machine but failed using the programmer. On a per lead basis, the ECG machine passes more subjects. It is unknown what the inappropriate shock rate would be if an S-ICD was implanted. Clinical judgment should be used in borderline cases. © 2018 Wiley Periodicals, Inc.

  3. Safety and interaction of patients with implantable cardiac defibrillators driving a hybrid vehicle.

    Science.gov (United States)

    Tondato, Fernando; Bazzell, Jane; Schwartz, Linda; Mc Donald, Bruce W; Fisher, Robert; Anderson, S Shawn; Galindo, Arcenio; Dueck, Amylou C; Scott, Luis R

    2017-01-15

    Electromagnetic interference (EMI) can affect the function of implantable cardioverter defibrillators (ICD). Hybrid electric vehicles (HEV) have increased popularity and are a potential source of EMI. Little is known about the in vivo effects of EMI generated by HEV on ICD. This study evaluated the in vivo interaction between EMI generated by HEV with ICD. Thirty patients (73±9 y/o; 80% male) with stable ICD function were exposed to EMI generated by a Toyota Prius Hybrid®. The vehicle was lifted above the ground, allowing safe changes in engine rotation and consequent variations in electromagnetic emission. EMI was measured (NARDA STS® model EHP-50C) and expressed in A/m (magnetic), Volts/m (electrical), and Hertz (frequency). Six positions were evaluated: driver, front passenger, right and left back seats, outside, at the back and front of the car. Each position was evaluated at idle, 30 mph, 60 mph and variable speeds (acceleration-deceleration-brake). All ICD devices were continuously monitored during the study. The levels of EMI generated were low (highest mean levels: 2.09A/m at right back seat at 30 mph; and 3.5V/m at driver seat at variable speeds). No episode of oversensing or inadvertent change in ICD programming was observed. It is safe for patients with ICD to interact with HEV. This is the first study to address this issue using an in vivo model. Further studies are necessary to evaluate the interaction of different models of HEV or electric engine with ICD or unipolar pacemakers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. A protocol for patients with cardiovascular implantable devices undergoing magnetic resonance imaging (MRI): should defibrillation threshold testing be performed post-(MRI).

    Science.gov (United States)

    Burke, Peter Thomas; Ghanbari, Hamid; Alexander, Patrick B; Shaw, Michael K; Daccarett, Marcos; Machado, Christian

    2010-06-01

    Magnetic resonance imaging (MRI) in patients with Cardiovascular Implantable Electronic Devices (CIED) has not been approved by the Food and Drug Administration. Recent data suggests MRI as a relative rather than absolute contraindication in CIED patients. Recently, the American Heart Association has recommended defibrillation threshold testing (DFTT) in implantable cardioverter defibrillator (ICD) patients undergoing MRI. We evaluated the feasibility and safety of a protocol for MRI in CIED patients, incorporating the new recommendations on DFTT. Consecutive patients with CIED undergoing MRI were included. The protocol consisted of continuous monitoring during imaging, device interrogation pre- and post-MRI, reprogramming of the pacemaker to an asynchronous mode in pacemaker-dependent (PMD) patients and a non-tracking/sensing mode for non-PMD patients. All tachyarrhythmia therapies were disabled. Devices were interrogated for lead impedance, battery life, pacing, and sensing thresholds. All patients with ICD underwent DFTT/defibrillator safety margin testing (DSMT) post-MRI. A total of 92 MRI's at 1.5 Tesla were performed in 38 patients. A total of 13 PMD patients, ten ICD patients, four cardiac resynchronization therapy with defibrillator (CRT-D) patients, and 11 non-PMD patients were scanned from four major manufacturers. No device circuitry damage, programming alterations, inappropriate shocks, failure to pace, or changes in sensing, pacing, or defibrillator thresholds were found on single or multiple MRI sessions. Our protocol for MRI in CIED patients appears safe, feasible, and reproducible. This is irrespective of the type of CIED, pacemaker dependancy or multiple 24-h scanning sessions. Our protocol addresses early detection of potential complications and establishes a response system for potential device-related complications. Our observation suggests that routine DFTT/DSMT post-MRI may not be necessary.

  5. Externalized conductors and insulation failure in Biotronik defibrillator leads: History repeating or a false alarm?

    Science.gov (United States)

    De Maria, Elia; Borghi, Ambra; Bonetti, Lorenzo; Fontana, Pier Luigi; Cappelli, Stefano

    2017-02-16

    Conductor externalization and insulation failure are frequent complications with the recalled St. Jude Medical Riata implantable cardioverter-defibrillator (ICD) leads. Conductor externalization is a "unique" failure mechanism: Cables externalize through the insulation ("inside-out" abrasion) and appear outside the lead body. Recently, single reports described a similar failure also for Biotronik leads. Moreover, some studies reported a high rate of electrical dysfunction (not only insulation failure) with Biotronik Linox leads and a reduced survival rate in comparison with the competitors. In this paper we describe the case of a patient with a Biotronik Kentrox ICD lead presenting with signs of insulation failure and conductor externalization at fluoroscopy. Due to the high risk of extraction we decided to implant a new lead, abandoning the damaged one; lead reimplant was uneventful. Subsequently, we review currently available literature about Biotronik Kentrox and Linox ICD lead failure and in particular externalized conductors. Some single-center studies and a non-prospective registry reported a survival rate between 88% and 91% at 5 years for Linox leads, significantly worse than that of other manufacturers. However, the preliminary results of two ongoing multicenter, prospective registries (GALAXY and CELESTIAL) showed 96% survival rate at 5 years after implant, well within industry standards. Ongoing data collection is needed to confirm longer-term performance of this family of ICD leads.

  6. Electrical storm presages nonsudden death: the antiarrhythmics versus implantable defibrillators (AVID) trial.

    Science.gov (United States)

    Exner, D V; Pinski, S L; Wyse, D G; Renfroe, E G; Follmann, D; Gold, M; Beckman, K J; Coromilas, J; Lancaster, S; Hallstrom, A P

    2001-04-24

    Electrical storm, multiple temporally related episodes of ventricular tachycardia (VT) or ventricular fibrillation (VF), is a frequent problem among recipients of implantable cardioverter defibrillators (ICDs). However, insufficient data exist regarding its prognostic significance. This analysis includes 457 patients who received an ICD in the Antiarrhythmics Versus Implantable Defibrillators (AVID) trial and who were followed for 31 +/- 13 months. Electrical storm was defined as > or = 3 separate episodes of VT/VF within 24 hours. Characteristics and survival of patients surviving electrical storm (n = 90), those with VT/VF unrelated to electrical storm (n = 184), and the remaining patients (n = 183) were compared. The 3 groups differed in terms of ejection fraction, index arrhythmia, revascularization status, and baseline medication use. Survival was evaluated using time-dependent Cox modeling. Electrical storm occurred 9.2 +/- 11.5 months after ICD implantation, and most episodes (86%) were due to VT. Electrical storm was a significant risk factor for subsequent death, independent of ejection fraction and other prognostic variables (relative risk [RR], 2.4; 95% confidence interval [CI], 1.3 to 4.2; P = 0.003), but VT/VF unrelated to electrical storm was not (RR, 1.0; 95% CI, 0.6 to 1.7; P = 0.9). The risk of death was greatest 3 months after electrical storm (RR, 5.4; 95% Cl, 2.4 to 12.3; P = 0.0001) and diminished beyond this time (RR, 1.9; 95% CI, 1.0 to 3.6; P=0.04). Electrical storm is an important, independent marker for subsequent death among ICD recipients, particularly in the first 3 months after its occurrence. However, the development of VT/VF unrelated to electrical storm does not seem to be associated with an increased risk of subsequent death.

  7. SU-E-T-169: Characterization of Pacemaker/ICD Dose in SAVI HDR Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kalavagunta, C; Lasio, G; Yi, B; Zhou, J; Lin, M [Univ. of Maryland School Of Medicine, Baltimore, MD (United States)

    2015-06-15

    Purpose: It is important to estimate dose to pacemaker (PM)/Implantable Cardioverter Defibrillator (ICD) before undertaking Accelerated Partial Breast Treatment using High Dose Rate (HDR) brachytherapy. Kim et al. have reported HDR PM/ICD dose using a single-source balloon applicator. To the authors knowledge, there have so far not been any published PM/ICD dosimetry literature for the Strut Adjusted Volume Implant (SAVI, Cianna Medical, Aliso Viejo, CA). This study aims to fill this gap by generating a dose look up table (LUT) to predict maximum dose to the PM/ICD in SAVI HDR brachytherapy. Methods: CT scans for 3D dosimetric planning were acquired for four SAVI applicators (6−1-mini, 6−1, 8−1 and 10−1) expanded to their maximum diameter in air. The CT datasets were imported into the Elekta Oncentra TPS for planning and each applicator was digitized in a multiplanar reconstruction window. A dose of 340 cGy was prescribed to the surface of a 1 cm expansion of the SAVI applicator cavity. Cartesian coordinates of the digitized applicator were determined in the treatment leading to the generation of a dose distribution and corresponding distance-dose prediction look up table (LUT) for distances from 2 to 15 cm (6-mini) and 2 to 20 cm (10–1).The deviation between the LUT doses and the dose to the cardiac device in a clinical case was evaluated. Results: Distance-dose look up table were compared to clinical SAVI plan and the discrepancy between the max dose predicted by the LUT and the clinical plan was found to be in the range (−0.44%, 0.74%) of the prescription dose. Conclusion: The distance-dose look up tables for SAVI applicators can be used to estimate the maximum dose to the ICD/PM, with a potential usefulness for quick assessment of dose to the cardiac device prior to applicator placement.

  8. Analysis of implantable defibrillator longevity under clinical circumstances: implications for device selection.

    Science.gov (United States)

    Knops, Paul; Theuns, Dominic A M J; Res, Jan C J; Jordaens, Luc

    2009-10-01

    Information about implantable cardioverter-defibrillator (ICD) longevity is mostly calculated from measurements under ideal laboratory conditions. However, little information about longevity under clinical circumstances is available. This survey gives an overview on ICD service times and generator replacements in a cohort of consecutive ICD patients. Indications for replacement were classified as a normal end-of-service (EOS), premature EOS, system malfunction, infection and device advisory, or recall actions. From the premature and normal EOS group, longevity from single-chamber (SC), dual-chamber (DC), and cardiac resynchronization therapy defibrillator (CRT-D), rate-responsive (RR) settings, high output (HO) stimulation, and indication for ICD therapy was compared. Differences between brands were compared as well. In a total of 854 patients, 203 ICD replacements (165 patients) were recorded. Premature and normal EOS replacements consisted of 32 SC, 98 DC and 24 CRT-D systems. Longevity was significantly longer in SC systems compared to DC and CRT-D systems (54 +/- 19 vs. 40 +/- 17 and 42 +/- 15 months; P = 0.008). Longevity between non-RR (n = 143) and RR (n = 11) settings was not significantly different (43 +/- 18 vs. 45 +/- 13 months) as it also was not for HO versus non-HO stimulation (43 +/- 19 vs. 46 +/- 17 months). Longevity of ICDs was not significantly different between primary and secondary prevention (42 +/- 19 vs. 44 +/- 18 months). The average longevity on account of a device-based EOS message was 43 +/- 18 months. Average longevity for Biotronik (BIO, n = 72) was 33 +/- 10 months, for ELA Medical (ELA, n = 12) 44 +/- 17 months, for Guidant (GDT, n = 36) 49 +/- 12 months, for Medtronic (MDT, n = 29) 62 +/- 22 months, and for St. Jude Medical (SJM, n = 5) 31 +/- 9 months (P generators had a longer service time compared to DC and CRT-D systems. No influence of indication for ICD therapy and HO stimulation on generator longevity was observed in this

  9. Electrical storm in patients with an implanted defibrillator: a matter of definition.

    Science.gov (United States)

    Israel, Carsten W; Barold, S Serge

    2007-10-01

    The term "electrical storm" (ES) indicates a state of cardiac electrical instability manifested by several episodes of ventricular tachyarrhythmias (VTs) within a short time. In patients with an implantable cardioverter defibrillator (ICD), ES is best defined as 3 appropriate VT detections in 24 h, treated by antitachycardia pacing, shock or eventually untreated but sustained in a VT monitoring zone. The number of shocks and inappropriate detections are irrelevant for the definition. ES occurs in approximately 25% of ICD patients within 3 years, with typically 5-55 individual VTs within one storm. Potential triggers can be found in approximately 66% of patients and include new/worsened heart failure, changes in antiarrhythmic medication, context with other illness, psychological stress, diarrhea, and hypokalemia. In most patients, ES consists of monomorphic VT indicating the presence of reentry while ventricular fibrillation indicating acute ischemia is rare. ES seems to have a low immediate mortality (1%) but frequently (50-80%) leads to hospitalization. Long-term prognostic implications of ES are unclear. The key intervention in ES is reduction of the elevated sympathetic tone by beta blockers and frequently benzodiazepines. Amiodarone i.v. has also been successful and azimilide seems promising while class I antiarrhythmic drugs are usually unsuccessful. Substrate mapping and VT ablation may be useful in treatment and prevention of ES. Prevention of ES requires ICD programming systematically avoiding unnecessary shocks (long VT detection, antitachycardia pacing where ever possible) which otherwise can fuel the sympathetic tone and prolong ES.

  10. Cardioverter-Defibrillator: A Treatment for Arrhythmia

    Science.gov (United States)

    ... abdomen (stomach area). It can go in a “pocket” under your skin or in a muscle. The ... counter Products Procedures & Devices Prescription Medicines Health Tools Dictionary Symptom Checker BMI Calculator myhealthfinder Immunization Schedules Nutrient ...

  11. Worldwide experience with a totally subcutaneous implantable defibrillator

    DEFF Research Database (Denmark)

    Lambiase, Pier D; Barr, Craig; Theuns, Dominic A M J

    2014-01-01

    AIMS: The totally subcutaneous implantable-defibrillator (S-ICD) is a new alternative to the conventional transvenous ICD system to minimize intravascular lead complications. There are limited data describing the long-term performance of the S-ICD. This paper presents the first large internationa...

  12. Feasibility of heart sounds measurements from an accelerometer within an ICD pulse generator.

    Science.gov (United States)

    Siejko, Krzysztof Z; Thakur, Pramodsingh H; Maile, Keith; Patangay, Abhilash; Olivari, Maria-Teresa

    2013-03-01

    The feasibility of detecting heart sounds (HS) from an accelerometer sensor enclosed within an implantable cardioverter defibrillator (ICD) pulse generator (PG) was explored in a noninvasive pilot study on heart failure (HF) patients with audible third HS (S3). Accelerometer circuitry enhanced for HS was incorporated into non-functional ICDs. A study was conducted on 30 HF patients and 10 normal subjects without history of cardiac disease. The devices were taped to the skin surface over both left and right pectoral regions to simulate subcutaneous implants. A lightweight reference accelerometer was taped over the cardiac apex. Waveforms were recorded simultaneously with a surface electrocardiogram for 2 minutes. Algorithms were developed to perform off-line automatic detection of HS and HS time intervals (HSTIs). S1, S2, and S3 vibrations were detected in all accelerometer locations for all 40 subjects, including 16 subjects without an audible S3. A substantial proportion of S3 energy was infrasonic (remote ambulatory monitoring of HF progression and the detection of the onset of HF decompensation. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

  13. Right versus left parasternal electrode position in the entirely subcutaneous ICD.

    Science.gov (United States)

    Bettin, Markus; Dechering, Dirk; Frommeyer, Gerrit; Larbig, Robert; Löher, Andreas; Reinke, Florian; Köbe, Julia; Eckardt, Lars

    2018-05-01

    The subcutaneous implantable cardioverter defibrillator (S-ICD ® ) has been established as an alternative to conventional transvenous ICD for the prevention of sudden cardiac death. Initial studies have shown safety and efficacy of the system with a left parasternal (LP) electrode. However, several case studies reported a right parasternal (RP) position. The purpose of this study was to analyze shock efficacy and safety of an RP electrode position. Between June 2010 and May 2016, 120 S-ICD ® were implanted at our institution. On the basis of the heart location on preoperative chest radiography (CXR), the investigators decided on an RP (n = 52) or LP electrode position (n = 68). All perioperative induced VF episodes, and spontaneous appropriate and inappropriate episodes during follow-up were analyzed. Patients with an RP electrode did not differ in terms of age, sex, or ejection fraction. A statistically significant difference in underlying cardiac disease was observed between the RP and LP electrode group, with more patients with channelopathies in the RP electrode group and more patients with non-ischemic cardiomyopathy in the LP electrode group. During a mean follow-up of 24.3 ± 19.5 months, 27 appropriate (19 in the LP group and 8 in the RP group) and 28 inappropriate (18 LP and 10 RP) ICD shocks occurred (p value = NS). In the present study, an RP electrode position was chosen on the basis of chest radiographic characteristics and was efficient in terms of sensing and shock efficacy. Thus, a right-sided electrode implant might be an alternative if a left-sided electrode implant is inadequate. It might also be favorable for young patients with narrow heart silhouettes in the midsagittal position.

  14. Superior Rhythm Discrimination With the SmartShock Technology Algorithm - Results of the Implantable Defibrillator With Enhanced Features and Settings for Reduction of Inaccurate Detection (DEFENSE) Trial.

    Science.gov (United States)

    Oginosawa, Yasushi; Kohno, Ritsuko; Honda, Toshihiro; Kikuchi, Kan; Nozoe, Masatsugu; Uchida, Takayuki; Minamiguchi, Hitoshi; Sonoda, Koichiro; Ogawa, Masahiro; Ideguchi, Takeshi; Kizaki, Yoshihisa; Nakamura, Toshihiro; Oba, Kageyuki; Higa, Satoshi; Yoshida, Keiki; Tsunoda, Soichi; Fujino, Yoshihisa; Abe, Haruhiko

    2017-08-25

    Shocks delivered by implanted anti-tachyarrhythmia devices, even when appropriate, lower the quality of life and survival. The new SmartShock Technology ® (SST) discrimination algorithm was developed to prevent the delivery of inappropriate shock. This prospective, multicenter, observational study compared the rate of inaccurate detection of ventricular tachyarrhythmia using the SST vs. a conventional discrimination algorithm.Methods and Results:Recipients of implantable cardioverter defibrillators (ICD) or cardiac resynchronization therapy defibrillators (CRT-D) equipped with the SST algorithm were enrolled and followed up every 6 months. The tachycardia detection rate was set at ≥150 beats/min with the SST algorithm. The primary endpoint was the time to first inaccurate detection of ventricular tachycardia (VT) with conventional vs. the SST discrimination algorithm, up to 2 years of follow-up. Between March 2012 and September 2013, 185 patients (mean age, 64.0±14.9 years; men, 74%; secondary prevention indication, 49.5%) were enrolled at 14 Japanese medical centers. Inaccurate detection was observed in 32 patients (17.6%) with the conventional, vs. in 19 patients (10.4%) with the SST algorithm. SST significantly lowered the rate of inaccurate detection by dual chamber devices (HR, 0.50; 95% CI: 0.263-0.950; P=0.034). Compared with previous algorithms, the SST discrimination algorithm significantly lowered the rate of inaccurate detection of VT in recipients of dual-chamber ICD or CRT-D.

  15. Assessing the Risks Associated with MRI in Patients with a Pacemaker or Defibrillator.

    Science.gov (United States)

    Russo, Robert J; Costa, Heather S; Silva, Patricia D; Anderson, Jeffrey L; Arshad, Aysha; Biederman, Robert W W; Boyle, Noel G; Frabizzio, Jennifer V; Birgersdotter-Green, Ulrika; Higgins, Steven L; Lampert, Rachel; Machado, Christian E; Martin, Edward T; Rivard, Andrew L; Rubenstein, Jason C; Schaerf, Raymond H M; Schwartz, Jennifer D; Shah, Dipan J; Tomassoni, Gery F; Tominaga, Gail T; Tonkin, Allison E; Uretsky, Seth; Wolff, Steven D

    2017-02-23

    The presence of a cardiovascular implantable electronic device has long been a contraindication for the performance of magnetic resonance imaging (MRI). We established a prospective registry to determine the risks associated with MRI at a magnetic field strength of 1.5 tesla for patients who had a pacemaker or implantable cardioverter-defibrillator (ICD) that was "non-MRI-conditional" (i.e., not approved by the Food and Drug Administration for MRI scanning). Patients in the registry were referred for clinically indicated nonthoracic MRI at a field strength of 1.5 tesla. Devices were interrogated before and after MRI with the use of a standardized protocol and were appropriately reprogrammed before the scanning. The primary end points were death, generator or lead failure, induced arrhythmia, loss of capture, or electrical reset during the scanning. The secondary end points were changes in device settings. MRI was performed in 1000 cases in which patients had a pacemaker and in 500 cases in which patients had an ICD. No deaths, lead failures, losses of capture, or ventricular arrhythmias occurred during MRI. One ICD generator could not be interrogated after MRI and required immediate replacement; the device had not been appropriately programmed per protocol before the MRI. We observed six cases of self-terminating atrial fibrillation or flutter and six cases of partial electrical reset. Changes in lead impedance, pacing threshold, battery voltage, and P-wave and R-wave amplitude exceeded prespecified thresholds in a small number of cases. Repeat MRI was not associated with an increase in adverse events. In this study, device or lead failure did not occur in any patient with a non-MRI-conditional pacemaker or ICD who underwent clinically indicated nonthoracic MRI at 1.5 tesla, was appropriately screened, and had the device reprogrammed in accordance with the prespecified protocol. (Funded by St. Jude Medical and others; MagnaSafe ClinicalTrials.gov number, NCT

  16. Remote monitoring improves outcome after ICD implantation: the clinical efficacy in the management of heart failure (EFFECT) study.

    Science.gov (United States)

    De Simone, Antonio; Leoni, Loira; Luzi, Mario; Amellone, Claudia; Stabile, Giuseppe; La Rocca, Vincenzo; Capucci, Alessandro; D'onofrio, Antonio; Ammendola, Ernesto; Accardi, Francesco; Valsecchi, Sergio; Buja, Gianfranco

    2015-08-01

    Internet-based remote interrogation systems have been shown to reduce emergency department and in-office visits in patients with implantable cardioverter defibrillators (ICDs), resulting in increased efficiency for healthcare providers. Nonetheless, studies sized to demonstrate the impact of remote monitoring on patients' outcome have been lacking. The EFFECT study was a multicentre clinical trial aimed at measuring and comparing the outcome of ICD patients conventionally followed-up by means of in-clinic visits (Standard arm) or by remote monitoring (Remote arm) in the clinical practice of 25 Italian centres. From 2011 to 2013, 987 consecutive patients were enrolled and followed up for at least 12 months. The primary endpoint was the rate of death and cardiovascular hospitalizations. Remote monitoring was adopted by 499 patients. Patients in the Standard and Remote arms did not differ significantly in terms of baseline clinical characteristics, except for a more frequent use of ICD with cardiac resynchronization therapy (CRT-D) in the Remote arm (48 vs. 36%, P Remote arm (incident rate ratio, 0.55; 95% CI, 0.41-0.73; P Remote arms were 0.27 and 0.08 events/year, respectively, among CRT-D recipients (P Remote arm. Compared with the standard follow-up through in-office visits, remote monitoring is associated with reduced death and cardiovascular hospitalizations in patients with ICD in clinical practice. URL: http://clinicaltrials.gov/ Identifier: NCT01723865. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  17. Pulse Generator Exchange Does Not Accelerate the Rate of Electrical Failure in a Recalled Small Caliber ICD Lead.

    Science.gov (United States)

    Lovelock, Joshua D; Premkumar, Ajay; Levy, Mathew R; Mengistu, Andenet; Hoskins, Michael H; El-Chami, Mikhael F; Lloyd, Michael S; Leon, Angel R; Langberg, Jonathan J; Delurgio, David B

    2015-12-01

    St. Jude Riata/Riata ST defibrillator leads (St. Jude Medical, Sylmar, CA, USA) were recalled by the Food and Drug Administration in 2011 for an increased rate of failure. More than 227,000 leads were implanted and at least 79,000 patients still have active Riata leads. Studies have examined clinical predictors of lead failure in Riata leads, but none have addressed the effect of implantable cardioverter defibrillator (ICD) generator exchange on lead failure. The purpose of this study is to assess the effect of ICD generator exchange on the rate of electrical failure in the Riata lead at 1 year. A retrospective chart review was conducted in patients who underwent implantation of a Riata/Riata ST lead at one center. Patients with a functioning Riata lead (with/without externalized conductor) at the time of ICD exchange were compared to controls with Riata leads implanted for a comparable amount of time who did not undergo generator replacement. Riata leads were implanted in 1,042 patients prior to the recall and 153 of these patients underwent generator exchange without lead replacement. Conductor externalization was noted in 21.5% of Riata leads in the ICD exchange cohort, which was not different from the control group (19.2%; P = 0.32). Two leads failed in the first year after generator replacement (1.5%) which did not significantly differ from the control group (2.0%; P = 0.57). At change-out, 54% received a commanded shock (18.6 ± 0.9 J) that did not result in any change in the high-voltage lead impedance (46.1 ± 1.1 ohms). Conductor externalization was seen frequently in our cohort of patients. ICD generator exchange did not accelerate the rate of Riata lead failure at 1 year. Although both the control and the change-out cohorts failed at a rate much greater than nonrecalled leads, generator exchange did not appear to add to the problem. ©2015 Wiley Periodicals, Inc.

  18. Estudo clínico de um sistema cardioversor-desfibrilador implantável que apresenta limiares de desfibrilação baixos usando eletrodos de estrutura fractal Clinical studies of an implantable cardioversor - defibrillators system providing low defibrillation thresholds as well as high signal amplitudes due to fractal coated electrodes

    Directory of Open Access Journals (Sweden)

    Fernando A. LUCCHESE

    1999-01-01

    Full Text Available Em função do contínuo desenvolvimento tecnológico, a geração atual de cardioversores-desfibriladores implantáveis (CDI garante um alto grau de segurança e eficiência na detecção e reversão de taquiarritmias ventriculares. O presente trabalho sumariza os resultados clínicos obtidos com 1058 CDI de câmara única (Phylax 6, Phylax XM, Biotronik utilizando eletrodo único e tecnologia de carcaça ativa, SPS e Kainox RV (com uma mola intracavitária de choque, SL-ICD e Kainox SL (com duas molas intracavitárias de choque, Biotronik. Na quase totalidade dos pacientes, com exceção de 3 (> 99%, foram obtidos limiares de desfibrilação com baixa energia usando apenas um eletrodo transvenoso. Isto tem permitido substituir o teste de limiar de desfibrilação usual por um teste simples durante o implante, afim de minimizar os riscos associados com repetidas induções de fibrilação e conseqüente extensão do período de anestesia.Due to continuously improved technologies, the present generation of implantable cardioverter-defibrillators (ICD guarantees a high degree of safety and efficacy for detecting and terminating ventricular tachyarrhythmias. This paper summarizes the clinical results obtained with 1058 single-chamber ICD (Phylax 6, Phylax XM, Biotronik employing single-lead and active housing technology (SPS and Kainox RV (single coil, SL-ICD and Kainox SL (double coil, Biotronik. In all but 3 patients (> 99%, reliable low-energy defibrillation was achieved using transvenous leads only. This has led to the trend to replace DFT testing by a short function test during implantation in order to minimize the risks associated with repeated induction of fibrillation and extended anesthesia.

  19. Validation of defibrillator lead performance registry data

    DEFF Research Database (Denmark)

    Kristensen, Anders Elgaard; Larsen, Jacob Moesgaard; Nielsen, Jens Cosedis

    2017-01-01

    all reported surgical interventions due to defibrillator lead events in the Danish Pacemaker and ICD Register (DPIR) from 2000 to 2013. Medical records of all patients (n = 753) were examined blinded for 5 predefined intervention types and 18 reasons for lead intervention. The overall level...

  20. Incidência de choques e qualidade de vida em jovens com cardioversor-desfibrilador implantável Incidence of shock and quality of life in young patients with implantable cardioverter-defibrillator

    Directory of Open Access Journals (Sweden)

    Roberto Costa

    2007-03-01

    Full Text Available OBJETIVOS: Avaliar a incidência e a causa de choques de CDI em crianças e adolescentes e sua repercussão na qualidade de vida (QV. MÉTODOS: De março/1997 a fevereiro/2006, 29 pacientes (15,7±5,4 anos foram submetidos a implante de CDI. Parada cardiorrespiratória recuperada (41,5%, taquicardia ventricular sustentada (27,6% e profilaxia primária de morte súbita cardíaca (30,9% motivaram os implantes. O número de terapias foi avaliado por entrevista e pela telemetria dos CDI. A QV foi avaliada pela aplicação do questionário SF-36 e comparada à de indivíduos saudáveis. Empregou-se o método de Kaplan-Meier para análise da sobrevida livre de choques. RESULTADOS: Após 2,6±1,8 anos de seguimento, 8 (27,6% pacientes receberam 141 choques apropriados em razão de TV polimórfica (6 ou FV (2, e 11 (37,9% sofreram 152 choques inapropriados em razão de taquiarritmias supraventriculares (8 ou oversensing (3. A expectativa de sobrevida livre de choques apropriados foi de 74,2%±9,0 após um ano, e de 66,7%±10,7 após três anos. Observou-se diminuição da QV nos aspectos físicos (61,7±28,7, na vitalidade (64,7±19,1, na saúde mental (65,9±22,7 e nos aspectos emocionais (66,7±38,5. Medo e preocupações relacionados ao CDI foram referidos por todos os pacientes. CONCLUSÃO: A despeito da grande eficácia dessa terapêutica, a incidência elevada de choques interferiu na QV e na adaptação ao dispositivo.OBJECTIVES: To analyze the incidence and causes of ICD therapies in children and young adults and verify their impact on the quality of life (QoL. METHODS: From March/1977 to February/2006, 29 patients (15.7±5.4 years old were submitted to ICD implants. Aborted cardiac arrest (41.5%, sustained ventricular tachycardia (27.6% and primary prophylaxis of sudden cardiac death (30.9% indicated device therapy. The number of therapies was evaluated by interviewing patients and by ICD diagnostic data. The SF-36 questionnaire was used to

  1. The impact of changes in LVEF and renal function on the prognosis of ICD patients after elective device replacement.

    Science.gov (United States)

    Vandenberk, Bert; Robyns, Tomas; Garweg, Christophe; Floré, Vincent; Foulon, Stefaan; Voros, Gabor; Ector, Joris; Willems, Rik

    2017-10-01

    A proportion of patients with an implantable cardioverter-defibrillator (ICD) in prevention of sudden cardiac death will only receive their first appropriate ICD therapy (AT) after device replacement. Clinical reassessment at the time of replacement could be helpful to guide the decision to replace or not in the future. All patients with an ICD for primary or secondary prevention in ischemic (ICM) or nonischemic cardiomyopathy were included in a single-center retrospective registry. The association of changes in left ventricular ejection fraction (LVEF; cut-off at 35%), worsening renal function (decrease in estimated glomerular filtration rate > 15 mL/min), and worsening New York Heart Association class at elective device replacement with mortality and AT was analyzed using adjusted Cox regression analysis. A total of 238 (33%) out of 727 patients received elective device replacement (86.1% male, 74.4% ICM, 42.9% primary prevention). During this replacement 20.2% received a device upgrade. The mean time to replacement was 6.4 ± 2.0 years and mean follow-up after replacement was 3.4 ± 3.0 years. Of patients who did not receive AT before replacement 23.1% received their first AT after replacement. Worsening renal function (hazard ratio [HR] 2.79, 95% confidence interval [CI] 1.50-5.18) and a consistently LVEF ≤35% compared to a consistently LVEF >35% (HR 2.15, 95% CI 1.10-4.19) at the time of replacement were independent predictors of mortality. Independent predictors of first AT after replacement could not be identified. Although reassessment of LVEF and renal function at replacement can be helpful in predicting total mortality, the clinical utility to guide reimplantation seemed limited. Our experience indicates that approximately 25% of patients received their first AT only after replacement. © 2017 Wiley Periodicals, Inc.

  2. Predictive value of cardiac autonomic indexes and MIBG washout in ICD recipients with mild to moderate heart failure

    International Nuclear Information System (INIS)

    Koutelou, M.; Katsikis, A.; Livanis, E.; Georgiadis, M.; Voudris, V.; Flevari, P.; Kremastinos, D.; Theodorakis, G.

    2009-01-01

    We aimed at evaluating the combined use of heart rate variability (HRV), baroreflex sensitivity (BRS), and metaiodobenzylguanidine (MIBG) imaging in the risk stratification for sudden cardiac death (SCD) of patients with mild to moderate heart failure. Twenty-five patients (17 male and 8 female, mean age 63±5 years, mean left ventricular ejection fraction (LVEF) 36±3%) with a recently implanted cardioverter-defibrillator (ICD) and mild (NYHA I-II) heart failure due to either ischemic (n=15) or dilated (n=10) cardiomyopathy were studied. One week after ICD implantation they underwent baroreflex sensitivity (BRS) evaluation to bolus phenylephrine by the Oxford method, 24-h heart rate variability (HRV) assessment, and MIBG imaging. The mean patient follow-up was 32±10 months. Simple correlation and stepwise multiple regression analysis was performed to evaluate if the number of sustained ventricular tachycardia (cycle length <330 ms) or fibrillation episodes per month is related to one or more of MIBG, BRS, and HRV indexes and if MIBG % washout is related to HRV and/or BRS. The frequency of fast ventricular arrhythmic episodes (FVAE) demonstrated an inverse relation to BRS (p<0.0001), rMSSD (p=0.001), and pNN50 (p=0.0034), while it was positively related to low frequency (LF) (p<0.0001) and MIBG % washout (p=0.001). BRS, LF, rMSSD, and MIBG washout were also independent predictors of FVAE. MIBG washout was related to only one HRV marker (SDNN-I, p<0.0001), while no correlation was observed with BRS. In ICD recipients with well-compensated heart failure, autonomic markers derived from BRS, HRV, and MIBG studies are related to FVAE. These markers have limited inter-dependency and constitute useful means for SCD risk stratification in this subgroup of patients. (author)

  3. A patch in the pectoral position lowers defibrillation threshold.

    Science.gov (United States)

    Karasik, P; Solomon, A; Verdino, R; Moore, H; Rodak, D; Hannan, R; Fletcher, R

    1997-06-01

    Implantable pacemaker cardioverter defibrillators are now available with biphasic waveforms, which have been shown to markedly improve defibrillation thresholds (DFTs). However, in a number of patients the DFT remains high. Also, DFT may increase after implantation, especially if antiarrhythmic drugs are added. We report on the use of a subcutaneous patch in the pectoral position in 15 patients receiving a transvenous defibrillator as a method of easily reducing the DFT. A 660-mm2 patch electrode was placed beneath the generator in a pocket created on the pectoral fascia. The energy required for defibrillation was lowered by 56% on average, and the system impedance was lowered by a mean of 25%. This maneuver allowed all patients to undergo a successful implant with adequate safety margin.

  4. ECG-derived spatial QRS-T angle is associated with ICD implantation, mortality and heart failure admissions in patients with LV systolic dysfunction.

    Directory of Open Access Journals (Sweden)

    Sarah Gleeson

    Full Text Available Increased spatial QRS-T angle has been shown to predict appropriate implantable cardioverter defibrilIator (ICD therapy in patients with left ventricular systolic dysfunction (LVSD. We performed a retrospective cohort study in patients with left ventricular ejection fraction (LVEF 31-40% to assess the relationship between the spatial QRS-T angle and other advanced ECG (A-ECG as well as echocardiographic metadata, with all-cause mortality or ICD implantation for secondary prevention.534 patients ≤75 years of age with LVEF 31-40% were identified through an echocardiography reporting database. Digital 12-lead ECGs were retrospectively matched to 295 of these patients, for whom echocardiographic and A-ECG metadata were then generated. Data mining was applied to discover novel ECG and echocardiographic markers of risk. Machine learning was used to develop a model to predict possible outcomes.49 patients (17% had events, defined as either mortality (n = 16 or ICD implantation for secondary prevention (n = 33. 72 parameters (58 A-ECG, 14 echocardiographic were univariately different (p110° had an adjusted HR of 3.4 (95% CI 1.6 to 7.4 for secondary ICD implantation or all-cause death and adjusted HR of 4.1 (95% CI 1.2 to 13.9 for future heart failure admission. There was a loss of complexity between A-ECG and echocardiographic variables with an increasing degree of disease.Spatial QRS-T angle >110° was strongly associated with arrhythmic events and all-cause death. Deep analysis of global ECG and echocardiographic metadata revealed underlying relationships, which otherwise would not have been appreciated. Delivered at scale such techniques may prove useful in clinical decision making in the future.

  5. Long Detection Programming in Single-Chamber Defibrillators Reduces Unnecessary Therapies and Mortality: The ADVANCE III Trial.

    Science.gov (United States)

    Gasparini, Maurizio; Lunati, Maurizio G; Proclemer, Alessandro; Arenal, Angel; Kloppe, Axel; Martínez Ferrer, Josè B; Hersi, Ahmad S; Gulaj, Marcin; Wijffels, Maurits C E; Santi, Elisabetta; Manotta, Laura; Varma, Niraj

    2017-11-01

    This study sought to evaluate the effects of programming a long detection in single-chamber (VVI) implantable cardioverter-defibrillators (ICDs) in the multicenter prospective ADVANCE III (Avoid DeliVering TherApies for Non-sustained Arrhythmias in ICD PatiEnts III) trial. Programming strategies may reduce unnecessary ICD shocks and their adverse effects but to date have been described only for dual-chamber ICDs. A total of 545 subjects (85% male; atrial fibrillation 25%, left ventricular ejection fraction 31%, ischemic etiology 68%, secondary prevention indications 32%) receiving a VVI ICD were randomized to long detection (30 of 40 intervals) or standard programming (18 of 24 intervals) based on device type, atrial fibrillation history, and indication. In both arms, antitachycardia pacing (ATP) therapy during charging was programmed for episodes with cycle length 320 to 200 ms and shock only for cycle length functions enabled. Therapies delivered were compared using a negative binomial regression model. A total of 267 patients were randomized to long detection and 278 to the control group. Median follow-up was 12 months. One hundred twelve therapies (shocks and ATP) occurred in the long detection arm versus 257 in the control arm, for a 48% reduction with 30 of 40 intervals (95% confidence interval [CI]: 0.36 to 0.76; p = 0.002). In the long detection arm, overall shocks were reduced by 40% compared to the control arm (48 vs. 24; 95% CI: 0.38 to 0.94; p = 0.026) and appropriate shocks by 51% (34 vs. 74; 95% CI: 0.26 to 0.94; p = 0.033). Syncopal events did not differ between arms, but survival improved in the long detection arm. Among patients implanted with a VVI ICD, programming with the long detection interval significantly reduced appropriate therapies, shocks, and all-cause mortality. (Avoid DeliVering TherApies for Non-sustained Arrhythmias in ICD PatiEnts III [ADVANCEIII]; NCT00617175). Copyright © 2017 The Authors. Published by Elsevier Inc. All

  6. Towards Low Energy Atrial Defibrillation

    Directory of Open Access Journals (Sweden)

    Philip Walsh

    2015-09-01

    Full Text Available A wireless powered implantable atrial defibrillator consisting of a battery driven hand-held radio frequency (RF power transmitter (ex vivo and a passive (battery free implantable power receiver (in vivo that enables measurement of the intracardiac impedance (ICI during internal atrial defibrillation is reported. The architecture is designed to operate in two modes: Cardiac sense mode (power-up, measure the impedance of the cardiac substrate and communicate data to the ex vivo power transmitter and cardiac shock mode (delivery of a synchronised very low tilt rectilinear electrical shock waveform. An initial prototype was implemented and tested. In low-power (sense mode, >5 W was delivered across a 2.5 cm air-skin gap to facilitate measurement of the impedance of the cardiac substrate. In high-power (shock mode, >180 W (delivered as a 12 ms monophasic very-low-tilt-rectilinear (M-VLTR or as a 12 ms biphasic very-low-tilt-rectilinear (B-VLTR chronosymmetric (6ms/6ms amplitude asymmetric (negative phase at 50% magnitude shock was reliably and repeatedly delivered across the same interface; with >47% DC-to-DC (direct current to direct current power transfer efficiency at a switching frequency of 185 kHz achieved. In an initial trial of the RF architecture developed, 30 patients with AF were randomised to therapy with an RF generated M-VLTR or B-VLTR shock using a step-up voltage protocol (50–300 V. Mean energy for successful cardioversion was 8.51 J ± 3.16 J. Subsequent analysis revealed that all patients who cardioverted exhibited a significant decrease in ICI between the first and third shocks (5.00 Ω (SD(σ = 1.62 Ω, p < 0.01 while spectral analysis across frequency also revealed a significant variation in the impedance-amplitude-spectrum-area (IAMSA within the same patient group (|∆(IAMSAS1-IAMSAS3[1 Hz − 20 kHz] = 20.82 Ω-Hz (SD(σ = 10.77 Ω-Hz, p < 0.01; both trends being absent in all patients that failed to cardiovert

  7. Risk factors and prognostic role of an electrical storm in patients after myocardial infarction with an implanted ICD for secondary prevention.

    Science.gov (United States)

    Kwaśniewski, Wojciech; Filipecki, Artur; Orszulak, Michał; Orszulak, Witold; Urbańczyk, Dagmara; Roczniok, Robert; Trusz-Gluza, Maria; Mizia-Stec, Katarzyna

    2018-04-01

    The aim of our study was to determine the risk factors for electrical storm (ES) and to assess the impact of ES on the long-term prognosis in patients after myocardial infarction (MI) with an implantable cardioverter-defibrillator (ICD) for secondary prevention of sudden cardiac death (SCD). We retrospectively analyzed 416 patients with coronary artery disease after MI who had an implanted ICD for secondary prevention of SCD. Fifty (12%) patients had one or more incidents of an electrical storm - the ES (+) group. We matched the reference group of 47 patients from 366 ES (-) patients. We analyzed 3,408 episodes of ventricular arrhythmias: 3,148 ventricular tachyarrhythmic episodes in the ES (+) group (including 187 episodes of ES) and 260 in the ES (-) group. Multivariate logistic regression showed that inferior wall MI (RR = 3.98, 95% CI: 1.52-10.41) and the absence of coronary revascularization (RR = 2.92, 95% CI: 1.18-7.21) were independent predictors of ES ( p = 0.0014). During 6-year observation of 97 patients, there were 39 (40%) deaths: 25 (50%) subjects in the ES (+) group and 14 (30%) in the ES (-) group ( p = 0.036). Independent predictors of death were: the occurrence of ES (HR = 1.93), older age (HR = 1.06), and lower left ventricular ejection fraction (HR = 0.95) (for all p storm in patients after MI with ICD for secondary prevention is a relatively common phenomenon and has a negative prognostic significance. Myocardial infarction of the inferior wall and the absence of coronary revascularization are predisposing factors for the occurrence of an ES.

  8. Sexual Health for Patients with an Implantable Cardioverter Defibrillator

    Science.gov (United States)

    ... sex for most patients represents only a moderate stress on the heart. Proposed Strategy Sex is a common concern, but most sexual activity ... all of your efforts, there are times when stress like this cannot be handled by ... patients should not engage in sex. Even if you feel you are not physically ...

  9. Pacemaker, implanted cardiac defibrillator and irradiation: Management proposal in 2010 depending on the type of cardiac stimulator and prognosis and location of cancer

    International Nuclear Information System (INIS)

    Lambert, P.; Da Costa, A.; Marcy, P.Y.; Kreps, S.; Angellier, G.; Marcie, S.; Bondiau, P.Y.; Briand-Amoros, C.; Thariat, J.

    2011-01-01

    Ionizing radiation may interfere with electric components of pacemakers or implantable cardioverter defibrillators. The type, severity and extent of radiation damage to pacemakers, have previously been shown to depend on the total dose and dose rate. Over 300,000 new cancer cases are treated yearly in France, among which 60% are irradiated in the course of their disease. One among 400 of these patients has an implanted pacemaker or defibrillator. The incidence of pacemaker and implanted cardioverter defibrillator increases in an ageing population. The oncologic prognosis must be weighted against the cardiologic prognosis in a multidisciplinary and transversal setting. Innovative irradiation techniques and technological sophistications of pacemakers and implantable cardioverter-defibrillators (with the introduction of more radiosensitive complementary metal-oxide-semiconductors since 1970) have potentially changed the tolerance profiles. This review of the literature studied the geometric, dosimetric and radiobiological characteristics of the radiation beams for high energy photons, stereotactic irradiation, proton-therapy. Standardized protocols and radiotherapy optimization (particle, treatment fields, energy) are advisable in order to improve patient management during radiotherapy and prolonged monitoring is necessary following radiation therapy. The dose received at the pacemaker/heart should be calculated. The threshold for the cumulated dose to the pacemaker/implantable cardioverter-defibrillator (2 to 5 Gy depending on the brand), the necessity to remove/displace the device based on the dose-volume histogram on dosimetry, as well as the use of lead shielding and magnet are discussed. (authors)

  10. Complications after cardiac implantable electronic device implantations

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard

    2013-01-01

    Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient...

  11. Management of radiation oncology patients with a pacemaker or ICD: A new comprehensive practical guideline in The Netherlands

    International Nuclear Information System (INIS)

    Hurkmans, Coen W; Knegjens, Joost L; Oei, Bing S; Maas, Ad JJ; Uiterwaal, GJ; Borden, Arnoud J van der; Ploegmakers, Marleen MJ; Erven, Lieselot van

    2012-01-01

    Current clinical guidelines for the management of radiotherapy patients having either a pacemaker or implantable cardioverter defibrillator (both CIEDs: Cardiac Implantable Electronic Devices) do not cover modern radiotherapy techniques and do not take the patient’s perspective into account. Available data on the frequency and cause of CIED failure during radiation therapy are limited and do not converge. The Dutch Society of Radiotherapy and Oncology (NVRO) initiated a multidisciplinary task group consisting of clinical physicists, cardiologists, radiation oncologists, pacemaker and ICD technologists to develop evidence based consensus guidelines for the management of CIED patients. CIED patients receiving radiotherapy should be categorised based on the chance of device failure and the clinical consequences in case of failure. Although there is no clear cut-off point nor a clear linear relationship, in general, chances of device failure increase with increasing doses. Clinical consequences of device failures like loss of pacing, carry the most risks in pacing dependent patients. Cumulative dose and pacing dependency have been combined to categorise patients into low, medium and high risk groups. Patients receiving a dose of less than 2 Gy to their CIED are categorised as low risk, unless pacing dependent since then they are medium risk. Between 2 and 10 Gy, all patients are categorised as medium risk, while above 10 Gy every patient is categorised as high risk. Measures to secure patient safety are described for each category. This guideline for the management of CIED patients receiving radiotherapy takes into account modern radiotherapy techniques, CIED technology, the patients’ perspective and the practical aspects necessary for the safe management of these patients. The guideline is implemented in The Netherlands in 2012 and is expected to find clinical acceptance outside The Netherlands as well

  12. Infectious endocardial intracardiac defibrillator lead, infectious pericarditis, and delayed constrictive pericarditis

    Directory of Open Access Journals (Sweden)

    Mohsen Mir Mohammad Sadeghi

    2013-01-01

    Full Text Available The usage of Implantable Cardiac Defibrillator (ICD since 1980s is becoming more popular these days. The rate of both, endocarditis and constrictive pericarditis are low but it still needs attention. We are reporting a rare case of ICD endocarditis as a result of toe infection in a diabetic patient. This was followed by infectious pericarditis after device removal by open heart surgery and then delayed constrictive pericarditis.

  13. Automated External Defibrillator

    Science.gov (United States)

    ... leads to a 10 percent reduction in survival. Training To Use an Automated External Defibrillator Learning how to use an AED and taking a CPR (cardiopulmonary resuscitation) course are helpful. However, if trained ...

  14. Definition of successful defibrillation

    NARCIS (Netherlands)

    Koster, Rudolph W.; Walker, Robert G.; van Alem, Anouk P.

    2006-01-01

    OBJECTIVES: The definition of defibrillation shock "success" endorsed by the International Liaison Committee on Resuscitation since the publication of Guidelines 2000 for Cardiopulmonary Resuscitation and Emergency Cardiac Care has been removal of ventricular fibrillation at 5 secs after shock

  15. Defibrillator patients should not be denied a peaceful death.

    Science.gov (United States)

    Westerdahl, Annika Kinch; Sutton, Richard; Frykman, Viveka

    2015-03-01

    Implantable defibrillators (ICDs) prevent sudden cardiac death. With declining health, ICD therapy may prolong death and expose the patient to unnecessary pain and anxiety. Few studies have addressed end of life care in ICD patients. The objective of this study was to investigate end of life in ICD patients, with respect to location of death; duration between do-not-resuscitate (DNR)-orders and deactivation of ICD therapy or DNR and time of death. A descriptive analysis of 65 deceased ICD patients, all whom had a written DNR-order before death, is presented. The majority (86%) was treated in hospitals, mainly (63%) university hospitals, and many (33%) in cardiology wards. Despite DNR-order, ICD shock therapy was active in 51% of all patients. In those with therapy deactivated at death, therapy deactivation was carried out two days or more after DNR-order in more than a third (38%). The time from DNR decision to death in patients with therapy active had a median of four days (IQR 1-38). During the last 24h of life, 24% of the patients experienced shock treatment. The majority of ICD patients with a DNR-order were treated in university hospitals. More than half still had shock treatment active at time of death with a median of four days or more between DNR decision and death. Patients with therapy deactivated, two days or more elapsed in more than a third from DNR decision to deactivation of therapy, exposing patients to a high risk of painful shocks before death. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  16. Pacemaker, implanted cardiac defibrillator and irradiation: Management proposal in 2010 depending on the type of cardiac stimulator and prognosis and location of cancer; Pacemaker, defibrillateur et radiotherapie: propositions de conduite a tenir en 2010 en fonction du type de stimulateur cardiaque, du pronostic et du site du cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lambert, P. [Service d' anesthesie reanimation, hopital Nord, centre hospitalier universitaire de Saint-etienne, 42055 Saint-etienne cedex 2 (France); Da Costa, A. [Service de cardiologie, hopital Nord, centre hospitalier universitaire de Saint-etienne, 42055 Saint-etienne cedex 2 (France); Marcy, P.Y. [Departement de radiologie, centre Antoine-Lacassagne, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Universite Nice Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Kreps, S. [Service de radiotherapie Corad, centre regional universitaire de cancerologie Henry-S.-Kaplan, hopital Bretonneau-2, CHU de Tours, boulevard Tonnelle, 37000 Tours (France); Angellier, G.; Marcie, S.; Bondiau, P.Y. [Universite Nice Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Departement de radiotherapie oncologie, centre CyberKnife, centre Antoine-Lacassagne, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Briand-Amoros, C. [Service de radiotherapie, hopital europeen Georges-Pompidou, 20, rue Leblanc, 75015 Paris (France); Thariat, J. [Universite Nice Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Departement de radiotherapie oncologie, centre CyberKnife, centre Antoine-Lacassagne, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); IBDC CNRS UMR 6543, centre Antoine-Lacassagne, universite Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France)

    2011-06-15

    Ionizing radiation may interfere with electric components of pacemakers or implantable cardioverter defibrillators. The type, severity and extent of radiation damage to pacemakers, have previously been shown to depend on the total dose and dose rate. Over 300,000 new cancer cases are treated yearly in France, among which 60% are irradiated in the course of their disease. One among 400 of these patients has an implanted pacemaker or defibrillator. The incidence of pacemaker and implanted cardioverter defibrillator increases in an ageing population. The oncologic prognosis must be weighted against the cardiologic prognosis in a multidisciplinary and transversal setting. Innovative irradiation techniques and technological sophistications of pacemakers and implantable cardioverter-defibrillators (with the introduction of more radiosensitive complementary metal-oxide-semiconductors since 1970) have potentially changed the tolerance profiles. This review of the literature studied the geometric, dosimetric and radiobiological characteristics of the radiation beams for high energy photons, stereotactic irradiation, proton-therapy. Standardized protocols and radiotherapy optimization (particle, treatment fields, energy) are advisable in order to improve patient management during radiotherapy and prolonged monitoring is necessary following radiation therapy. The dose received at the pacemaker/heart should be calculated. The threshold for the cumulated dose to the pacemaker/implantable cardioverter-defibrillator (2 to 5 Gy depending on the brand), the necessity to remove/displace the device based on the dose-volume histogram on dosimetry, as well as the use of lead shielding and magnet are discussed. (authors)

  17. Public Access Defibrillation

    DEFF Research Database (Denmark)

    Agerskov, Marianne; Nielsen, Anne Møller; Hansen, Carolina Malta

    2015-01-01

    BACKGROUND: In Copenhagen, a volunteer-based Automated External Defibrillator (AED) network provides a unique opportunity to assess AED use. We aimed to determine the proportion of Out-of-Hospital Cardiac Arrest (OHCA) where an AED was applied before arrival of the ambulance, and the proportion o...

  18. Unexpected ICD pulse generator failure due to electronic circuit damage caused by electrical overstress.

    Science.gov (United States)

    Hauser, R G; Hayes, D L; Almquist, A K; Epstein, A E; Parsonnet, V; Tyers, G F; Vlay, S C; Schoenfeld, M H

    2001-07-01

    Because it is a lifesaving device, the unexpected failure of an ICD can be catastrophic. We report ICD electronic circuit failure due to electrical overstress damage (EOS) to the high voltage hybird circuit and other electronic components in a series of ICD pulse generator models. Data were obtained from the Multicenter Registry of Pacemaker and ICD Pacemaker and Lead Failures, and from the manufactures' adverse event reports, that were in the FDA's Manufacturer and User Facility Device Experience (MAUDE) database. Of 16 nonbattery Guidant/CPI ICD pulse generator failures reported to the registry, 6 (38%) have been confirmed by the manufacturer to be EOS related, and Guidant/CPI has reported 273 such failures to the FDA as of 12/29/00. The signs of failure included loss of telemetry and inability to deliver therapy, and some patients have experienced serious adverse events. Hybrid circuit damage may have occurred during capacitor charging or reform, and the majority appears to have happened during normal ICD function. While the incidence of this problem is unknown, a management strategy should be adopted that includes routine follow-up every 3 months and device evaluation after a shock or exposure to external defibrillation or electrosurgical devices. This study suggests that additional data are needed to determine the incidence of this problem, and that our present methods for monitoring the performance of ICD's following market release are inadequate.

  19. Pacing and Defibrillators in Complex Congenital Heart Disease

    Science.gov (United States)

    Chubb, Henry; O’Neill, Mark; Rosenthal, Eric

    2016-01-01

    Device therapy in the complex congenital heart disease (CHD) population is a challenging field. There is a myriad of devices available, but none designed specifically for the CHD patient group, and a scarcity of prospective studies to guide best practice. Baseline cardiac anatomy, prior surgical and interventional procedures, existing tachyarrhythmias and the requirement for future intervention all play a substantial role in decision making. For both pacing systems and implantable cardioverter defibrillators, numerous factors impact on the merits of system location (endovascular versus non-endovascular), lead positioning, device selection and device programming. For those with Fontan circulation and following the atrial switch procedure there are also very specific considerations regarding access and potential complications. This review discusses the published guidelines, device indications and the best available evidence for guidance of device implantation in the complex CHD population. PMID:27403295

  20. An International External Validation Study of the 2014 European Society of Cardiology Guideline on Sudden Cardiac Death Prevention in Hypertrophic Cardiomyopathy (Evidence from HCM)

    DEFF Research Database (Denmark)

    O'Mahony, Constantinos; Jichi, Fatima; Ommen, Steve R

    2018-01-01

    Background -Identification of people with hypertrophic cardiomyopathy (HCM) who are at risk of sudden cardiac death (SCD) and require prophylactic implantable cardioverter defibrillator (ICD) is challenging. In 2014, the European Society of Cardiology (ESC) proposed a new risk stratification meth...

  1. Co-constructing IT and Healthcare

    DEFF Research Database (Denmark)

    Andersen, Tariq Osman; Bansler, Jørgen P.; Bjørn, Pernille

    The CITH project (Co-constructing IT and Healthcare) is an ongoing 4-year interdisciplinary research project, which investigates while intervenes in the collaborative practices involved in disease management of chronic heart patients with an ICD (Implantable Cardioverter Defibrillator)....

  2. Prognostic value of tissue Doppler imaging for predicting ventricular arrhythmias and cardiovascular mortality in ischaemic cardiomyopathy

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Olsen, Flemming Javier; Storm, Katrine

    2016-01-01

    AIMS: Only 30% of patients receiving an implantable cardioverter defibrillator (ICD) for primary prevention receive appropriately therapy. We sought to investigate the value of tissue Doppler imaging (TDI) to predict ventricular tachycardia (VT), ventricular fibrillation (VF), and cardiovascular...

  3. Therapeutic options in chronic heart failure. Findings on chest X-ray; Nicht medikamentoese Therapieoptionen der chronischen Herzinsuffizienz. Befunde in der Projektionsradiografie des Thorax

    Energy Technology Data Exchange (ETDEWEB)

    Granitz, M.R.; Meissnitzer, T.; Meissnitzer, M.W.; Hergan, K.; Altenberger, J.; Granitz, C. [Uniklinikum Salzburg - Landeskrankenhaus (Austria)

    2016-05-15

    The contribution covers drugless therapeutic options for chronic heart failure: the implantable cardioverter/defibrillator (ICD), the cardiac resynchronization therapy (CRT), the interventional catheter treatment of functional mitral insufficiency, and mechanical heart supporting systems and heart transplantation.

  4. Therapeutic options in chronic heart failure. Findings on chest X-ray

    International Nuclear Information System (INIS)

    Granitz, M.R.; Meissnitzer, T.; Meissnitzer, M.W.; Hergan, K.; Altenberger, J.; Granitz, C.

    2016-01-01

    The contribution covers drugless therapeutic options for chronic heart failure: the implantable cardioverter/defibrillator (ICD), the cardiac resynchronization therapy (CRT), the interventional catheter treatment of functional mitral insufficiency, and mechanical heart supporting systems and heart transplantation.

  5. [Electrical storm in patients with prophylactic defibrillator implantation].

    Science.gov (United States)

    Rodríguez-Mañero, Moisés; González-Cambeiro, Cristina; Moreno-Arribas, Jose; Expósito-García, Víctor; Sánchez-Gómez, Juan Miguel; González-Torres, Luis; Arce-León, Álvaro; Arguedas-Jiménez, Hugo; Gaztañaga, Larraitz; Salvador-Montañés, Oscar; Iglesias-Bravo, Jose Antonio; Huerta, Ana Andrés La; Fernández-Armenta, Juan; Arias, Miguel Ángel; Martínez-Sande, Luis

    2016-01-01

    Little is known about the prevalence of electrical storm, baseline characteristics and mortality implications of patients with implantable cardioverter defibrillator in primary prevention versus those patients without electrical storm. We sought to assess the prevalence, baseline risk profile and survival significance of electrical storm in patients with implantable defibrillator for primary prevention. Retrospective multicenter study performed in 15 Spanish hospitals. Consecutives patients referred for desfibrillator implantation, with or without left ventricular lead (at least those performed in 2010 and 2011), were included. Over all 1,174 patients, 34 (2,9%) presented an electrical storm, mainly due to ventricular tachycardia (82.4%). There were no significant baseline differences between groups, with similar punctuation in the mortality risk scores (SHOCKED, MADIT and FADES). A clear trigger was identified in 47% of the events. During the study period (38±21 months), long-term total mortality (58.8% versus 14.4%, pstorm patients. Rate of inappropriate desfibrillator intervention was also higher (14.7 versus 8.6%, pstorm was 2.9%. There were no baseline differences in the cardiovascular risk profile versus those without electrical storm. However, all cause mortality and cardiovascular mortality was increased in these patients versus control desfibrillator patients without electrical storm, as was the rate of inappropriate desfibrillator intervention. Copyright © 2015 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  6. Implanted Cardiac Defibrillator Care in Radiation Oncology Patient Population

    International Nuclear Information System (INIS)

    Gelblum, Daphna Y.; Amols, Howard

    2009-01-01

    Purpose: To review the experience of a large cancer center with radiotherapy (RT) patients bearing implantable cardiac defibrillators (ICDs) to propose some preliminary care guidelines as we learn more about the devices and their interaction with the therapeutic radiation environment. Methods and Materials: We collected data on patients with implanted ICDs treated with RT during a 2.5-year period at any of the five Memorial Sloan-Kettering clinical campuses. Information regarding the model, location, and dose detected from the device, as well as the treatment fields, fraction size, and treatment energy was collected. During this time, a new management policy for these patients had been implemented requiring treatment with low-energy beams (6 MV) and close surveillance of the patients in partnership with their electrophysiologist, as they received RT. Results: During the study period, 33 patients were treated with an ICD in place. One patient experienced a default of the device to its initial factory setting that was detected by the patient hearing an auditory signal from the device. This patient had initially been treated with a 15-MV beam. After this episode, his treatment was replanned to be completed with 6-MV photons, and he experienced no further events. Conclusion: Patients with ICDs and other implanted computer-controlled devices will be encountered more frequently in the RT department, and proper management is important. We present a policy for the safe treatment of these patients in the radiation oncology environment.

  7. Y2K: effects on pacemaker and implantable defibrillator programmers.

    Science.gov (United States)

    Flynn, D P; Daubert, J P; Huang, D T; Ocampo, C M; O'Gorman, E

    1999-01-01

    All permanent pacemakers and implantable defibrillators (PPM/ICDs) will continue to function as programmed without regard to the date in the year 2000 (Y2K). All manufacturers contacted reassured us that some of these devices incorporate a day/year clock in the circuitry; however, these are not involved in sensing or delivering programmed therapy. Some manufacturers' device programmers will roll over to the year 2000 without any problems at all, whereas others may have difficulty with date and time stamping on printed reports. We tested 14 different types of PPM/ICD programmers for Y2K compliance using 8 tests. Five of the 14 models passed each test and were labeled at our institution with a green "Y2K" sticker to identify them as Y2K compatible and needing no special attention after December 31, 1999. The most common test failed was the ability to roll the date forward from December 31, 1999, with the programmer power off. Organizations should consider testing and replacing noncompliant device programmers or placing a red sticker with "Y2K" crossed out on noncompliant pieces. The red sticker alerts the advanced practice nurse or physician to the need to confirm the appropriate date and time in the programmer after startup in the year 2000 and before interrogating or programming any PPM/ICD, to avoid inappropriate date and time stamping on printed reports from that programmer.

  8. Specific and social phobias in ICD-11

    NARCIS (Netherlands)

    Emmelkamp, P.M.G.

    2012-01-01

    The purpose of this article is to discuss the current status of research with respect to specific phobias and social phobia as defined in the ICD-10 and DSM-IV, and to provide op- tions for their classification in the ICD-11. Both ICD-10 and DSM-IV identify three main classes of phobias: specific

  9. Variability in clinical diagnoses during the ICD-8 and ICD-10 era

    DEFF Research Database (Denmark)

    Frederiksen, Julie E Nordgaard; Jessen, Kasper; Sæbye, Ditte

    2016-01-01

    university-affiliated departments of psychiatry in Denmark in two time periods: 1980-1985 (ICD-8) and 2001-2010 (ICD-10). RESULTS: The synchronic inter-departmental diagnostic differences did not decrease in the ICD-10 era compared with ICD-8 era. Nor did the diachronic stability within each department...

  10. Hypochondriasis: considerations for ICD-11

    Directory of Open Access Journals (Sweden)

    Odile A. van den Heuvel

    2014-01-01

    Full Text Available The World Health Organization (WHO is currently revisiting the ICD. In the 10th version of the ICD, approved in 1990, hypochondriacal symptoms are described in the context of both the primary condition hypochondriacal disorder and as secondary symptoms within a range of other mental disorders. Expansion of the research base since 1990 makes a critical evaluation and revision of both the definition and classification of hypochondriacal disorder timely. This article addresses the considerations reviewed by members of the WHO ICD-11 Working Group on the Classification of Obsessive-Compulsive and Related Disorders in their proposal for the description and classification of hypochondriasis. The proposed revision emphasizes the phenomenological overlap with both anxiety disorders (e.g., fear, hypervigilance to bodily symptoms, and avoidance and obsessive-compulsive and related disorders (e.g., preoccupation and repetitive behaviors and the distinction from the somatoform disorders (presence of somatic symptom is not a critical characteristic. This revision aims to improve clinical utility by enabling better recognition and treatment of patients with hypochondriasis within the broad range of global health care settings.

  11. Electromagnetic Interference from Swimming Pool Generator Current Causing Inappropriate ICD Discharges

    Directory of Open Access Journals (Sweden)

    Edward Samuel Roberto

    2017-01-01

    Full Text Available Electromagnetic interference (EMI includes any electromagnetic field signal that can be detected by device circuitry, with potentially serious consequences: incorrect sensing, pacing, device mode switching, and defibrillation. This is a unique case of extracardiac EMI by alternating current leakage from a submerged motor used to recycle chlorinated water, resulting in false rhythm detection and inappropriate ICD discharge. A 31-year-old female with arrhythmogenic right ventricular cardiomyopathy and Medtronic dual-chamber ICD placement presented after several inappropriate ICD shocks at the public swimming pool. Patient had never received prior shocks and device was appropriate at all regular follow-ups. Intracardiac electrograms revealed unique, high-frequency signals at exactly 120 msec suggestive of EMI from a strong external source of alternating current. Electrical artifact was incorrectly sensed as a ventricular arrhythmia which resulted in discharge. ICD parameters including sensing, pacing thresholds, and impedance were all normal suggesting against device malfunction. With device failure and intracardiac sources excluded, EMI was therefore strongly suspected. Avoidance of EMI source brought complete resolution with no further inappropriate shocks. After exclusion of intracardiac interference, device malfunction, and abnormal settings, extracardiac etiologies such as EMI must be thoughtfully considered and excluded. Elimination of inappropriate shocks is to “first, do no harm.”

  12. Using left-ventricular-only pacing to eliminate T-wave oversensing in a biventricular implantable cardiac defibrillator.

    Science.gov (United States)

    Khoo, Clarence; Bennett, Matthew; Chakrabarti, Santabhanu; LeMaitre, John; Tung, Stanley K K

    2013-02-01

    A man aged 75 years and with nonischemic cardiomyopathy had implantation of a biventricular implantable cardiac defibrillator (ICD). Consistent biventricular pacing was limited by intermittent T-wave oversensing (TWOS). A strategy of left-ventricular-only pacing was used to eliminate TWOS. This strategy obviates the need to reduce ventricular sensitivity and thus may be an effective alternative to biventricular pacing complicated by TWOS. Copyright © 2013 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  13. Echocardiography and cardiac MRI in mutation-negative hypertrophic cardiomyopathy in an older patient: a case defining the need for ICD.

    Science.gov (United States)

    Rodriguez, Fatima; Degnan, Kathleen O; Seidman, Christine E; Mangion, Judy R

    2014-08-01

    We report the case of a 67-year-old man with hypertrophic cardiomyopathy who presented for a second opinion about implantable cardio-defibrillator (ICD) placement after a witnessed syncopal episode. Despite his older age, being mutation-negative, and having a maximal septal thickness of 2.2 cm on echocardiography, he demonstrated rapid progression of myocardial fibrosis on cardiac MRI, correlating to ventricular tachyarrhythmias and syncope. We review the role of echocardiography and cardiac MRI in optimizing medical care for such patients who may not otherwise meet criteria for an ICD placement or further interventions. © 2014, Wiley Periodicals, Inc.

  14. [Septic shock due to infective endocarditis of stimulation system of implantable cardioverter-defibrillator].

    Science.gov (United States)

    Porubčinová, I; Porubčin, S; Stančák, B; Beňa, M; Sabol, F

    2012-01-01

    We present a case of a 60-year old patient hospitalized at the Department of Infectious Diseases and Travel Medicine, Medical faculty of UPJS and L. Pasteurs University Hospital in Kosice with suspected gastroenteritis. The patient was admitted to an intensive care unit because of the signs of septic shock. Within one hour from admission, the patient was administered early goal directed therapy for septic shock. Subsequently, infectious endocarditis of stimulation electrodes and tricuspid valve was identified as the origin of the infection. The stimulation system was then explanted from a stabilized and afebrile patient at the Department of cardiac Surgery of Eastern Slovak Institute of Cardiac and Vascular Diseases in Kosice. This case should emphasise frequently atypical course of this serious disease and the need for early identification of severe sepsis to enable timely management to affect mortality.

  15. Low disease prevalence and inappropriate implantable cardioverter defibrillator shock rate in Brugada syndrome

    DEFF Research Database (Denmark)

    Holst, Anders Gaarsdal; Jensen, Henrik Kjærulf; Eschen, Ole

    2012-01-01

    AimsBrugada syndrome (BrS) is an inherited channelopathy that predisposes to malignant ventricular arrhythmias and thereby syncope and sudden cardiac death. Prior studies characterizing BrS patients have used highly selected referral populations from tertiary centres and prevalence estimates have...... been carried out using electrocardiogram (ECG) surveys only. We aimed to identify and characterize all diagnosed BrS patients in Denmark (population 5.4 million).Methods and resultsBrugada syndrome patients were identified using several modalities including identification in all Danish tertiary......%) experienced inappropriate shocks during a median follow-up of 47 months. No patient died or experienced aborted sudden cardiac death during follow-up.ConclusionsWe report the first nationwide study of BrS patients. We found a low incidence of diagnosed definite BrS compared with estimates from ECG surveys...

  16. Clinical effects and implications of cardiac rehabilitation for implantable cardioverter defibrillator patients

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Moons, Philip; Christensen, Anne Vingaard

    2015-01-01

    rehabilitation and usual care was found in physical capacity and general and mental health. However, the clinical effect sizes of these findings were not investigated, and the findings from the quantitative and qualitative analyses were not triangulated to address the issue of whether the qualitative results...... could help explain the quantitative results and bring forward additional information. OBJECTIVES:: The objectives are to (a) determine the clinical effect sizes of the primary outcomes and (b) triangulate the quantitative and qualitative findings. METHODS:: A total of 196 patients with first...... d was calculated. Qualitative interviews were conducted with 10 patients representing the rehabilitation group. Triangulation was carried out by integrating the findings from the quantitative and qualitative results in light of each other. RESULTS:: Clinically meaningful effects were found between...

  17. Long-term mortality risk in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Theuns, Dominic A M J; Pedersen, Susanne S.

    2014-01-01

    .9)). The impact of heart rate and QRS duration on time to all-cause mortality was separately assessed with Cox proportional hazard regression analysis, adjusting for clinical factors and symptoms of depression and anxiety. RESULTS: Mean (SD) heart rate was 68.0 ± 13.3 bpm and mean QRS duration was 130.9 ± 36.9 ms....... Heart rate of ≥80 bpm was associated with increased risk of mortality (HR=1.86; 95% CI=1.15-3.00; p=.011) in unadjusted analysis. In adjusted analyses, this relationship remained significant both with depression (HR=1.86, 95% CI=1.12-3.09; p=.017) and anxiety (HR=1.82, 95% CI=1.10-3.03; p=.021...

  18. Intensity of primary emotions in patients after implantation of an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Stoier, Louise; Pedersen, Preben Ulrich; Berg, Selina Kikkenborg

    2013-01-01

    -November 2009. A total number of 154 patients were needed in the trial. The data collected were compared with secondary data from patients who had recently suffered a Myocardial Infarction and from a healthy population. SPSS version 18.0 was used to analyze the data using t-test, chisquare and F...

  19. Failure to Treat Life-Threatening Ventricular Tachyarrhythmias in Contemporary Implantable Cardioverter-Defibrillators

    DEFF Research Database (Denmark)

    Thøgersen, Anna Margrethe; Larsen, Jacob Moesgaard; Johansen, Jens Brock

    2017-01-01

    . CONCLUSIONS: Complex and unanticipated interactions between manufacturer-specific features and generic programming can prevent therapy for VF. More data are needed to assess the risks and benefits of translating evidence-based detection parameters from one manufacturer to another....

  20. Coping with Trauma and Stressful Events As a Patient with an Implantable Cardioverter-Defibrillator

    Science.gov (United States)

    ... Circulation My alerts Sign In Join Sign out Facebook Twitter Home About this Journal Editorial Board General Statistics Circulation Doodle Information for Advertisers Author Reprints Commercial Reprints Customer Service and Ordering ...

  1. Relation of statin therapy to psychological functioning in patients with an implantable cardioverter defibrillator

    NARCIS (Netherlands)

    Hoogwegt, M.T.; Theuns, D.A.M.J.; Kupper, N.; Jordaens, L.; Pedersen, S.S.

    2013-01-01

    Statin therapy is an important secondary prevention measure in cardiovascular disease. However, the side effects associated with statin use could potentially affect patients' quality of life. Little is known about the influence of statin therapy on the well-being and health status of cardiac

  2. My Child Needs or Has an Implantable Cardioverter-Defibrillator: What Should I Do?

    Science.gov (United States)

    ... al. 7 How Can We Boost My Child's Self-Esteem? No matter what the age, a fun way ... to treatment among children with cardiac disease . Cardiol Young . 2009 ; 19 : 545 – 551 . OpenUrl CrossRef PubMed 3. ↵ ...

  3. 77 FR 20873 - Qualification of Drivers; Application for Exemptions; Implantable Cardioverter Defibrillators

    Science.gov (United States)

    2012-04-06

    ..., please include a self-addressed, stamped envelope or postcard or print the acknowledgement page that... variety known to be accompanied by syncope, dyspnea, collapse, or congestive cardiac failure. FMCSA..., collapse or congestive cardiac failure; and/or (2) which is likely to cause syncope, dyspnea, collapse, or...

  4. Sex differences in outcomes of primary prevention implantable cardioverter defibrillator therapy

    DEFF Research Database (Denmark)

    Sticherling, Christian; Arendacka, Barbora; Svendsen, Jesper Hastrup

    2018-01-01

    measures were overall mortality and first appropriate and first inappropriate shocks. A multivariable model enforcing a common hazard ratio for sex category across the centres, but allowing for centre-specific baseline hazards and centre specific effects of other covariates, was adjusted for age...

  5. Use of Automated External Defibrillators

    Energy Technology Data Exchange (ETDEWEB)

    Gregory K Christensen

    2009-02-01

    In an effort to improve survival from cardiac arrest, the American Heart Association (AHA) has promoted the Chain of Survival concept, describing a sequence of prehospital steps that result in improved survival after sudden cardiac arrest. These interventions include immediate deployment of emergency medical services, prompt cardiopulmonary resuscitation, early defibrillation when indicated, and early initiation of advanced medical care. Early defibrillation has emerged as the most important intervention with survival decreasing by 10% with each minute of delay in defibrillation. Ventricular Fibrillation (VF) is a condition in which there is uncoordinated contraction of the heart cardiac muscle of the ventricles in the heart, making them tremble rather than contract properly. VF is a medical emergency and if the arrhythmia continues for more than a few seconds, blood circulation will cease, and death can occur in a matter of minutes. During VF, contractions of the heart are not synchronized, blood flow ceases, organs begin to fail from oxygen deprivation and within 10 minutes, death will occur. When VF occurs, the victim must be defibrillated in order to establish the heart’s normal rhythm. On average, the wait for an ambulance in populated areas of the United States is about 11 minutes. In view of these facts, the EFCOG Electrical Safety Task Group initiated this review to evaluate the potential value of deployment and use of automated external defibrillators (AEDs) for treatment of SCA victims. This evaluation indicates the long term survival benefit to victims of SCA is high if treated with CPR plus defibrillation within the first 3-5 minutes after collapse. According to the American Heart Association (AHA), survival rates as high as 74% are possible if treatment and defibrillation is performed in the first 3 minutes. In contrast survival rates are only 5% where no AED programs have been established to provide prompt CPR and defibrillation. ["CPR statistics

  6. Conventional and right-sided screening for subcutaneous ICD in a population with congenital heart disease at high risk of sudden cardiac death.

    Science.gov (United States)

    Alonso, Pau; Osca, Joaquín; Rueda, Joaquín; Cano, Oscar; Pimenta, Pedro; Andres, Ana; Sancho, María José; Martinez, Luis

    2017-11-01

    Information regarding suitability for subcutaneous defibrillator (sICD) implantation in tetralogy of Fallot (ToF) and systemic right ventricle is scarce and needs to be further explored. The main objective of our study was to determine the proportion of patients with ToF and systemic right ventricle eligible for sICD with both, standard and right-sided screening methods. Secondary objectives were: (i) to study sICD eligibility specifically in patients at high risk of sudden cardiac death, (ii) to identify independent predictors for sICD eligibility, and (iii) to compare the proportion of eligible patients in a nonselected ICD population. We recruited 102 patients with ToF, 33 with systemic right ventricle, and 40 consecutive nonselected patients. Conventional electrocardiographic screening was performed as usual. Right-sided alternative screening was studied by positioning the left-arm and right-arm electrodes 1 cm right lateral of the xiphoid midline. The Boston Scientific ECG screening tool was utilized. In high-risk patients with ToF, eligibility was higher with right-sided screening in comparison with standard screening (61% vs. 44%; p = .018). Eligibility in high-risk right ventricle population was identical with both screening methods (77%, p = ns). The only independent predictor for sICD eligibility was QRS duration. In high-risk patients with ToF, right-sided implantation of the sICD could be an alternative to a conventional ICD. In patients with a systemic right ventricle, implantation of a sICD is an alternative to a conventional sICD. © 2017 Wiley Periodicals, Inc.

  7. Ventricular fibrillation in an ambulatory patient supported by a left ventricular assist device: highlighting the ICD controversy.

    Science.gov (United States)

    Boilson, Barry A; Durham, Lucian A; Park, Soon J

    2012-01-01

    Left ventricular assist devices (LVADs) provide an effective means of managing advanced pump failure as a means of bridging to cardiac transplantation or as permanent therapy. Although ventricular arrhythmias remain common post-LVAD implantation, such therapy may allow malignant arrhythmias to be tolerated hemodynamically. This report describes the clinical findings in a patient who had likely been in a ventricular tachyarrhythmia for several days and presented in ventricular fibrillation, ambulatory, and mentating normally. This report, with previous similar reports, is additive to the body of evidence that LVADs alter the physiologic impact of ventricular arrhythmias in advanced heart failure and highlights the need for thoughtful programming of implantable cardioverter defibrillator therapies in these patients.

  8. Wireless Heart Patients and the Quantified Self

    DEFF Research Database (Denmark)

    Grew, Julie Christina; Svendsen, Mette Nordahl

    2017-01-01

    Remote monitoring of implantable cardioverter defibrillator (ICD) patients links patients wirelessly to the clinic via a box in their bedroom. The box transmits data from the ICD to a remote database accessible to clinicians without patient involvement. Data travel across time and space; clinicia...

  9. Rationale and design of WEBCARE

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Spek, Viola; Theuns, Dominic A M J

    2009-01-01

    The implantable cardioverter defibrillator (ICD) is generally well accepted, but 25-33% of patients experience clinical levels of anxiety, depression, and impaired quality of life (QoL) following implantation. Few trials in ICD patients have investigated whether behavioral intervention may mitiga...

  10. The use of variability of repolarization for monitoring of arrhythmic risk : "the rocking of the boat"

    NARCIS (Netherlands)

    Oosterhoff, P.

    2011-01-01

    The majority of deaths in the western world are of cardiovascular origin. Approximately 60% of these cardiovascular deaths are sudden. Implantation of an implantable cardioverter defibrillator (ICD) has been proven effective in preventing sudden cardiac death in patients at increased risk. An ICD

  11. Reliability of clinical ICD-10 schizophrenia diagnoses

    DEFF Research Database (Denmark)

    Jakobsen, Klaus D; Frederiksen, Julie N; Hansen, Thomas

    2005-01-01

    Concern has been expressed as to the reliability of clinical ICD-10 diagnosis of schizophrenia. This study was designed to assess the diagnostic reliability of the clinical ICD-10 diagnosis of schizophrenia in a random sample of Danish in- and outpatients with a history of psychosis. A sample...... value (87%) of ICD-10 schizophrenia and an overall good agreement between clinical and OPCRIT-derived diagnoses (kappa=0.60). An even higher positive predictive value was obtained when diagnoses were amalgamated into a diagnostic entity of schizophrenia-spectrum disorders (98%). Near perfect agreement...... was seen between OPCRIT-derived ICD-10 and DSM-IV diagnoses (kappa=0.87). Thus, this study demonstrates high reliability of the clinical diagnosis of schizophrenia and even more so of the diagnosis of schizophrenia-spectrum disorder....

  12. A second defibrillator chest patch electrode will increase implantation rates for nonthoracotomy defibrillators.

    Science.gov (United States)

    Solomon, A J; Swartz, J F; Rodak, D J; Moore, H J; Hannan, R L; Tracy, C M; Fletcher, R D

    1996-09-01

    Nonthoracotomy defibrillator systems can be implanted with a lower morbidity and mortality, compared to epicardial systems. However, implantation may be unsuccessful in up to 15% of patients, using a monophasic waveform. It was the purpose of this study to prospectively examine the efficacy of a second chest patch electrode in a nonthoracotomy defibrillator system. Fourteen patients (mean age 62 +/- 11 years, ejection fraction = 0.29 +/- 0.12) with elevated defibrillation thresholds, defined as > or = 24 J, were studied. The initial lead system consisted of a right ventricular electrode (cathode), a left innominate vein, and subscapular chest patch electrode (anodes). If the initial defibrillation threshold was > or = 24 J, a second chest patch electrode was added. This was placed subcutaneously in the anterior chest (8 cases), or submuscularly in the subscapular space (6 cases). This resulted in a decrease in the system impedance at the defibrillation threshold, from 72.3 +/- 13.3 omega to 52.2 +/- 8.6 omega. Additionally, the defibrillation threshold decreased from > or = 24 J, with a single patch, to 16.6 +/- 2.8 J with two patches. These changes were associated with successful implantation of a nonthoracotomy defibrillator system in all cases. In conclusion, the addition of a second chest patch electrode (using a subscapular approach) will result in lower defibrillation thresholds in patients with high defibrillation thresholds, and will subsequently increase implantation rates for nonthoracotomy defibrillators.

  13. Interaction of defibrillation waveform with the time to defibrillation or the number of defibrillation attempts on survival from out-of-hospital cardiac arrest.

    Science.gov (United States)

    Hagihara, Akihito; Onozuka, Daisuke; Ono, Junko; Nagata, Takashi; Hasegawa, Manabu

    2018-01-01

    Early biphasic defibrillation is effective in out-of-hospital cardiac arrest (OHCA) cases. In the resuscitation of patients with OHCA, it is not clear how the defibrillation waveform interacts with the time to defibrillation to influence patient survival. The second, and any subsequent, shocks need to be administered by an on-line physician in Japan. Thus, we investigated the interaction between the defibrillation waveform and time to or the number of defibrillation on resuscitation outcomes. This prospective observational study used data for all OHCAs that occurred between 2005 and 2014 in Japan. To investigate the interaction effect between the defibrillation waveform and the time to defibrillation or the number of defibrillations on the return to spontaneous circulation (ROSC), 1-month survival, and cerebral performance category (CPC) (1, 2), we assessed the modifying effects of the defibrillation waveform and the time to or the number of defibrillation on additive scale (i.e., the relative excessive risk due to interaction, RERI) and multiplicative scale (i.e., ratio of odds ratios (ORs)). In total, 71,566 cases met the inclusion criteria. For the measure of interaction between the defibrillation waveform and the time to defibrillation, ratio of ORs for ROSC was 0.84 (0.75-0.94), implying that the effect of time to first defibrillation on ROSC was negatively modified by defibrillation waveform. For the interaction between the defibrillation waveform and the number of defibrillations, RERI and ratio of ORs for CPC (1, 2) was -0.25 (-0.47 to -0.06) and 0.79 (0.67-0.93), respectively. It is implied that the effect of number of defibrillation on CPC (1, 2) was negatively modified by defibrillation waveform. An increased number of defibrillations was associated with a decreased ROSC in the case of biphasic and monophasic defibrillation, while an increased number of defibrillations was related to an increased 1-month survival rate and CPC (1, 2) only in the case of

  14. From syncope to ICD: clinical paths of the Brugada syndrome

    Directory of Open Access Journals (Sweden)

    Ivan Comelli

    2010-09-01

    Full Text Available This review summarizes the evidences in the literature on the management of the Brugada syndrome (BS, an arrhythmogenic disease caused by genetic channelopathies, predisposing to syncope and sudden cardiac death in young, apparently healthy, typically male subjects, in the third and fourth decade of their life. Sudden cardiac death (SCD is defined as natural death from cardiac causes, heralded by abrupt loss of consciousness within one hour of the onset of symptoms. It ranks among the main causes of death in the western world, with an incidence ranging from 0.36 and 1.28‰ inhabitants per year, equal to 300,000 cases a year in the USA. In the majority of the cases it is due to the onset of arrhythmia in subjects with structural cardiac diseases, especially ischemic heart disease. However, in a non-negligible percentage of the cases, about 5-10%, the SCD arises in relatively young individuals in whom cardiac anomalies cannot be detected using traditional diagnostic techniques. About 20% of these cases can be attributed to SB. In spite of the many efforts produced to identify an effective pharmacological treatment, to date the only aid to reduce the mortality rate in subjects with SB is an implantable cardio-defibrillator (ICD. Since this approach often entails complications, the efforts of the scientific community is now focused on the assessment of the arrhythmic risk. The identification of high-risk subjects is one of the chief objectives in the therapeutic decision-making process. ABSTRACT clinica e terapia emergency

  15. Inappropriate shocks in the subcutaneous ICD

    DEFF Research Database (Denmark)

    Olde Nordkamp, Louise R A; Brouwer, Tom F; Barr, Craig

    2015-01-01

    shocks have been reported. METHODS: We analyzed the incidence, predictors and management of inappropriate shocks in the EFFORTLESS S-ICD Registry, which collects S-ICD implantation information and follow-up data from clinical centers in Europe and New Zealand. RESULTS: During a follow-up of 21 ± 13...... xyphoid to V6) reduced the risk. Reprogramming or optimization of SVT treatment after the first clinical event of inappropriate shock was successful in preventing further inappropriate shocks for cardiac oversensing and SVT events. CONCLUSIONS: Inappropriate shocks, mainly due to cardiac oversensing...

  16. Study Design and Cohort Description of DEFIB-WOMEN

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Nielsen, Jens Cosedis; Riahi, Sam

    2016-01-01

    BACKGROUND: Little systematic evidence is available on potential gender differences in patients with an implantable cardioverter defibrillator (ICD) from a real-world cohort. We designed the DEFIB-WOMEN (The Utilization of Implantable Cardioverter DEFIBrillator Therapy in the Treatment of Heart......-converting enzyme inhibitors, and psychotropic agents. Although women generally had a healthier clinical profile, they reported significantly more symptoms of anxiety and depression and ICD concerns (fear of shock) as compared to men. These differences were not only statistically significant but also clinically...

  17. State of the art of ICD programming

    DEFF Research Database (Denmark)

    Mastenbroek, M H; Pedersen, Susanne S.; Versteeg, H

    2014-01-01

    , were eligible to participate. In all patients a prolonged detection of 60/80 intervals was programmed. The primary objective of the study is to investigate whether enhanced programming to further reduce ICD therapies is safe. The secondary objective is to examine the impact of enhanced programming...

  18. Are central hospitals ready for National Health Insurance? ICD ...

    African Journals Online (AJOL)

    ICD coding quality from an electronic patient discharge record for clinicians. ... RE Dyers, J Evans, GA Ward, S du Plooy, H Mahomed ... After 6 months, the quality of ICD codes was determined by comparing ICD code descriptors with medical concepts in a random sample of original patient records selected over a 6-week ...

  19. Stereotyped movement disorder in ICD-11.

    Science.gov (United States)

    Stein, Dan J; Woods, Douglas W

    2014-01-01

    According to current proposals for ICD-11, stereotyped movement disorder will be classified in the grouping of neurodevelopmental disorders, with a qualifier to indicate whether self-injury is present, similar to the classification of stereotypic movement disorder in DSM-5. At the same time, the WHO ICD-11 Working Group on the Classification of Obsessive-Compulsive and Related Disorders has proposed a grouping of body-focused repetitive behavior disorders within the obsessive-compulsive and related disorders (OCRD) cluster to include trichotillomania and skin-picking disorder. DSM-5 has taken a slightly different approach: trichotillomania and excoriation (skin picking) disorder are included in the OCRD grouping, while body-focused repetitive behavior disorder is listed under other specified forms of OCRD. DSM-5 also includes a separate category of nonsuicidal self-injury in the section on "conditions for further study." There are a number of unresolved nosological questions regarding the relationships among stereotyped movement disorder, body-focused repetitive behavior disorders, and nonsuicidal self-injury. In this article, we attempt to provide preliminary answers to some of these questions as they relate to the ICD-11 classification of mental and behavioral disorders.

  20. Atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy.

    Science.gov (United States)

    Sticherling, Christian; Müller, Dirk; Schaer, Beat A; Krüger, Silke; Kolb, Christof

    2018-03-27

    Many patients receiving cardiac resynchronization therapy (CRT) suffer from permanent atrial fibrillation (AF). Knowledge of the atrial rhythm is important to direct pharmacological or interventional treatment as well as maintaining AV-synchronous biventricular pacing if sinus rhythm can be restored. A single pass single-coil defibrillator lead with a floating atrial bipole has been shown to obtain reliable information about the atrial rhythm but has never been employed in a CRT-system. The purpose of this study was to assess the feasibility of implanting a single coil right ventricular ICD lead with a floating atrial bipole and the signal quality of atrial electrograms (AEGM) in CRT-defibrillator recipients with permanent AF. Seventeen patients (16 males, mean age 73 ± 6 years, mean EF 25 ± 5%) with permanent AF and an indication for CRT-defibrillator placement were implanted with a designated CRT-D system comprising a single pass defibrillator lead with a atrial floating bipole. They were followed-up for 103 ± 22 days using remote monitoring for AEGM transmission. All patients had at last one AEGM suitable for atrial rhythm diagnosis and of 100 AEGM 99% were suitable for visual atrial rhythm assessment. Four patients were discharged in sinus rhythm and one reverted to AF during follow-up. Atrial electrograms retrieved from a single-pass defibrillator lead with a floating atrial bipole can be reliably used for atrial rhythm diagnosis in CRT recipients with permanent AF. Hence, a single pass ventricular defibrillator lead with a floating bipole can be considered in this population. Copyright © 2018 Indian Heart Rhythm Society. Production and hosting by Elsevier B.V. All rights reserved.

  1. New horizon for infection prevention technology and implantable device

    Directory of Open Access Journals (Sweden)

    Yusuke Kondo, MD, PhD

    2016-08-01

    Full Text Available There has been a significant increase in the number of patients receiving cardiovascular implantable electronic devices (CIED over the last two decades. CIED infection represents a serious complication after CIED implantation and is associated with significant morbidity and mortality. Recently, newly advanced technologies have offered attractive and suitable therapeutic alternatives. Notably, the leadless pacemaker and anti-bacterial envelope decrease the potential risk of CIED infection and the resulting mortality, when it does occur. A completely subcutaneous implantable cardioverter defibrillator is also an alternative to the transvenous implantable cardioverter defibrillator (ICD, as it does not require implantation of any transvenous or epicardial leads. Among the patients who require ICD removal and subsequent antibiotics secondary to infection, the wearable cardioverter defibrillator represents an alternative approach to inpatient monitoring for the prevention of sudden cardiac death. In this review paper, we aimed to introduce the advanced technologies and devices for prevention of CIED infection.

  2. [Public access defibrillation: successful cardiopulmonary resuscitation due to automatic external defibrillator at traffic accident].

    Science.gov (United States)

    Wanke, S; Reuter, H; Pfister, R; Michels, G

    2014-03-01

    A 65-year-old man collapsed after he stepped out of his car after a traffic accident. Fortunately, two police officers on a routine patrol in the area were quickly on the scene and started cardiopulmonary resuscitation. A passerby noticed that the patient was in distress and that an automatic defibrillator was nearby. He attached the electrodes of the defibrillator to the chest of the patient in accordance with instructions on the defibrillator and terminated the ventricular fibrillation (200 joule, biphasic). Emergency cardiac catheterization revealed a subtotal stenosis proximally in the right coronary artery, which was successfully treated with a stent. Based on the ideal basic life support, the immediate care by emergency mobile system and coronary angioplasty with successful revascularisation the patient could be released without any neurological deficit. This case illustrates that laypersons can use automatic external defibrillator in case of cardiac resuscitation sufficiently and quickly. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Significant impact of electrical storm on mortality in patients with structural heart disease and an implantable cardiac defibrillator.

    Science.gov (United States)

    Noda, Takashi; Kurita, Takashi; Nitta, Takashi; Chiba, Yasutaka; Furushima, Hiroshi; Matsumoto, Naoki; Toyoshima, Takeshi; Shimizu, Akihiko; Mitamura, Hideo; Okumura, Ken; Ohe, Tohru; Aizawa, Yoshifusa

    2018-03-15

    Electrical storm (E-Storm), defined as multiple episodes of ventricular arrhythmias within a short period of time, is an important clinical problem in patients with an implantable cardiac defibrillator (ICD) including cardiac resynchronization therapy devices capable of defibrillation. The detailed clinical aspects of E-Storm in large populations especially for non-ischemic dilated cardiomyopathy (DCM), however, remain unclear. This study was performed to elucidate the detailed clinical aspects of E-Storm, such as its predictors and prevalence among patients with structural heart disease including DCM. We analyzed the data of the Nippon Storm Study, which was a prospective observational study involving 1570 patients enrolled from 48 ICD centers. For the purpose of this study, we evaluated 1274 patients with structural heart disease, including 482 (38%) patients with ischemic heart disease (IHD) and 342 (27%) patients with DCM. During a median follow-up of 28months (interquartile range: 23 to 33months), E-Storm occurred in 84 (6.6%) patients. The incidence of E-Storm was not significantly different between patients with IHD and patients with DCM (log-rank p=0.52). Proportional hazard regression analyses showed that ICD implantation for secondary prevention of sudden cardiac death (p=0.0001) and QRS width (p=0.015) were the independent risk factors for E-storm. In a comparison between patients with and without E-Storm, survival curves after adjustment for clinical characteristics showed a significant difference in mortality. E-Storm was associated with subsequent mortality in patients with structural heart disease including DCM. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  4. Neurodevelopmental Disorders (ASD and ADHD): DSM-5, ICD-10, and ICD-11.

    Science.gov (United States)

    Doernberg, Ellen; Hollander, Eric

    2016-08-01

    Neurodevelopmental disorders, specifically autism spectrum disorder (ASD) and attention-deficit/hyperactivity disorder (ADHD) have undergone considerable diagnostic evolution in the past decade. In the United States, the current system in place is the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5), whereas worldwide, the International Statistical Classification of Diseases and Related Health Problems, Tenth Revision (ICD-10) serves as a general medical system. This review will examine the differences in neurodevelopmental disorders between these two systems. First, we will review the important revisions made from the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision (DSM-IV-TR) to the DSM-5, with respect to ASD and ADHD. Next, we will cover the similarities and differences between ASD and ADHD classification in the DSM-5 and the ICD-10, and how these differences may have an effect on neurodevelopmental disorder diagnostics and classification. By examining the changes made for the DSM-5 in 2013, and critiquing the current ICD-10 system, we can help to anticipate and advise on the upcoming ICD-11, due to come online in 2017. Overall, this review serves to highlight the importance of progress towards complementary diagnostic classification systems, keeping in mind the difference in tradition and purpose of the DSM and the ICD, and that these systems are dynamic and changing as more is learned about neurodevelopmental disorders and their underlying etiology. Finally this review will discuss alternative diagnostic approaches, such as the Research Domain Criteria (RDoC) initiative, which links symptom domains to underlying biological and neurological mechanisms. The incorporation of new diagnostic directions could have a great effect on treatment development and insurance coverage for neurodevelopmental disorders worldwide.

  5. Substance use and addictive disorders in DSM-5 and ICD 10 and the draft ICD 11.

    Science.gov (United States)

    Saunders, John B

    2017-07-01

    The present review compares and contrasts the diagnostic entities and taxonomy of substance use and addictive disorders in the beta draft of the Eleventh Revision of the International Classification of Diseases (ICD 11), which was released in November 2016, and the Fifth Edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5), which was published in mid-2013. Recently published papers relevant to these two classification systems are examined. New initiatives in diagnosis and assessment including the addictions neuroclinical assessment are noted. The draft ICD 11 retains substance dependence as the 'master diagnosis' in contrast to the broader and heterogeneous concept of substance use disorder in DSM-5 and there is empirical support for the coherence of substance dependence for alcohol, cannabis, and prescribed opioids. Both systems now include gambling disorder in the addictive disorders section, with it being transferred from the impulse control disorders section. The new diagnosis of Internet gaming disorder is included in DSM-5 as a condition for further study, and gaming disorder is grouped with the substance and gambling disorders in the draft ICD 11. Initiatives from the U.S. National Institutes of Health (NIH) are highlighting the importance of capturing the neurobiological phases of the addictive cycle in clinical diagnosis and assessment. Although most of the changes in the draft ICD 11 and DSM-5 are incremental, the contrast between DSM-5 substance use disorder and substance dependence in the draft ICD 11, and the inclusion of gambling disorder and gaming disorder will generate much discussion and research.

  6. Association between implantable cardioverter-defibrillator therapy and different lead positions in patients with cardiac resynchronization therapy

    DEFF Research Database (Denmark)

    Kronborg, Mads Brix; Johansen, Jens Brock; Haarbo, Jens

    2017-01-01

    /mid-ventricular/apical for the LV-LP, and as apical/non-apical for the RV-LP. Appropriate and inappropriate therapies were registered during follow-up via remote monitoring or at device interrogations. Time to event was summarized with Kaplan-Meier plots, and competed risk regression analysis was used to calculate adjusted hazard...... with an apical. We observed no significant association between appropriate therapy and LV-LP in left anterior oblique or right anterior oblique views or inappropriate therapy between any lead positions. Conclusion: An apical RV-LP is associated with an increased risk of appropriate therapy for ventricular...

  7. Self-reported quality of life predicts mortality 7 years post implant in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Andersen, Christina Maar; Veen, Barbara van; Theuns, Dominic A M J

    2018-01-01

    (SD) age=58 (12) consecutively implanted between 2003 and 2010. Patients completed the SF-36. The eight subscales and the physical and mental component summary scores were used as predictors of mortality 7 years post implant. Results: At 7-year follow-up, 33.7% (132/392) of the patients had died...

  8. Dollars and sense: Mitigating budget risk for ICD-10.

    Science.gov (United States)

    Newell, Lucy Mancini; DeSilva, Joseph J

    2013-02-01

    The extended deadline for ICD-10 implementation is time that should not be wasted. Healthcare leaders should keep three things in mind: CFOs should approach the effort knowing the costs of ICD-10 implementation will be high and spread over multiple budget years. Training, productivity, and contractual issues are among key areas that will be challenged by ICD-10 implementation. Healthcare finance leaders should work to improve cash-on-hand and cash reserves prior to the ICD-10 deadline to ensure liquidity post-compliance.

  9. Designing Shared Electronic Records for Chronic Care

    DEFF Research Database (Denmark)

    Bansler, Jørgen Peter; Havn, Erling C.; Mønsted, Troels

    2010-01-01

    ICDs (implantable cardioverter-defibrillator). These are chronic patients who usually see several different healthcare providers on a regular basis. The main findings so far are: (1) Most of the data produced and recorded as part of the care process are context-specific and often difficult to interpret...

  10. Will medical examination gloves protect rescuers from defibrillation voltages during hands-on defibrillation?

    Science.gov (United States)

    Sullivan, Joseph L; Chapman, Fred W

    2012-12-01

    Continuing compressions during a defibrillation shock has been proposed as a method of reducing pauses in cardiopulmonary resuscitation (CPR) but the safety of this procedure is unproven. The medical examination gloves worn by rescuers play an important role in protecting the rescuer yet the electrical characteristics of these gloves are unknown. This study examined the response of medical examination gloves to defibrillation voltages. Part 1 of this study measured voltage-current curves for a small sample (8) of gloves. Part 2 tested more gloves (460) to determine the voltage required to produce a specific amount of current flow. Gloves were tested at two current levels: 0.1 mA and 10 mA. Testing included four glove materials (chloroprene, latex, nitrile, and vinyl) in a single layer and double-gloved. All gloves tested in part 1 allowed little current to flow (gloves and 93 of 120 (77%) double gloves allowed at least 0.1 mA of current flow at voltages within the external defibrillation voltage range. Also, 6 of 80 (7.5%) single gloves and 5 of 80 (6.2%) double gloves allowed over 10 mA. Few of the gloves tested limited the current to levels proven to be safe. A lack of sensation during hands-on defibrillation does not guarantee that a safety margin exists. As such, we encourage rescuers to minimize rather than eliminate the pause in compressions for defibrillation. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  11. The ICD diagnoses of fetishism and sadomasochism.

    Science.gov (United States)

    Reiersøl, Odd; Skeid, Svein

    2006-01-01

    In this article we discuss psychiatric diagnoses of sexual deviation as they appear in the International Classification of Diseases (ICD-10), the internationally accepted classification and diagnostic system of the World Health Organization (WHO). Namely, we discuss the background of three diagnostic categories: Fetishism (F65.0), Fetishistic Transvestism (F65.1), and Sadomasochism (F65.5). Pertinent background issues regarding the above categories are followed by a critique of the usefulness of diagnosing these phenomena today. Specifically, we argue that Fetishism, Fetishistic Transvestism, and Sadomasochism, also labeled Paraphilia or perversion, should not be considered illnesses. Finally, we present the efforts of an initiative known as ReviseF65, which was established in 1997, to abolish these diagnoses.

  12. [Cause-of-death statistics and ICD, quo vadis?

    Science.gov (United States)

    Eckert, Olaf; Vogel, Ulrich

    2018-07-01

    The International Statistical Classification of Diseases and Related Health Problems (ICD) is the worldwide binding standard for generating underlying cause-of-death statistics. What are the effects of former revisions of the ICD on underlying cause-of-death statistics and which opportunities and challenges are becoming apparent in a possible transition process from ICD-10 to ICD-11?This article presents the calculation of the exploitation grade of ICD-9 and ICD-10 in the German cause-of-death statistics and quality of documentation. Approximately 67,000 anonymized German death certificates are processed by Iris/MUSE and official German cause-of-death statistics are analyzed.In addition to substantial changes in the exploitation grade in the transition from ICD-9 to ICD-10, regional effects become visible. The rate of so-called "ill-defined" conditions exceeds 10%.Despite substantial improvement of ICD revisions there are long-known deficits in the coroner's inquest, filling death certificates and quality of coding. To make better use of the ICD as a methodological framework for mortality statistics and health reporting in Germany, the following measures are necessary: 1. General use of Iris/MUSE, 2. Establishing multiple underlying cause-of-death statistics, 3. Introduction of an electronic death certificate, 4. Improvement of the medical assessment of cause of death.Within short time the WHO will release the 11th revision of the ICD that will provide additional opportunities for the development of underlying cause-of-death statistics and their use in science, public health and politics. A coordinated effort including participants in the process and users is necessary to meet the related challenges.

  13. Fast Electrocardiogram Amplifier Recovery after Defibrillation Shock

    Directory of Open Access Journals (Sweden)

    Ivan Dotsinsky

    2005-04-01

    Full Text Available A procedure for fast ECG amplifier recovery after defibrillation shocks was developed and simulated in the MATLAB environment. Exponentially decaying post-shock voltages have been recorded. Signals from the AHA database are taken and mixed with the recorded exponential disturbances. The algorithm applies moving averaging (comb filter on the compound input signal, thereby obtaining the samples of the disturbance. They are currently subtracted from the input signal. The results obtained show that its recovery is practically instantaneous.

  14. COPE-ICD: Patient experience of participation in an ICD specific rehabilitation programme

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Pedersen, Birthe Dagmar; Svendsen, Jesper Hastrup

    2012-01-01

    individualized care. Four themes emerged: Knowledge: patients gained much needed understanding; Physical attention: patients interpreted body signals and adjusted their exercise behaviour; Trust: patients regained trust, felt secure and dared to live again; Strategies of living: patients' coping was supported...... through reflection and professional dialogue, and they dealt with the risk of shock or death. CONCLUSION: Participating in an ICD-specific rehabilitation programme can make patients feel inspired and secure through individualized care. They discover that they have to rethink some of their strategies......PURPOSE: Evaluating rehabilitation programmes from the patient's perspective is much needed, as the patients are the most important stakeholders in the health care system. A comprehensive rehabilitation programme, COPE-ICD programme, consists of exercise training and nursing consultations during...

  15. Impact of the Transition to ICD-10 on Medicare Payment

    Data.gov (United States)

    U.S. Department of Health & Human Services — Although the transition from the ICD-9-CM to the ICD-10 version of MS-DRGs resulted in 1.68 percent of the patients being assigned to a different MS-DRG, payment...

  16. Identification of ICD Codes Suggestive of Child Maltreatment

    Science.gov (United States)

    Schnitzer, Patricia G.; Slusher, Paula L.; Kruse, Robin L.; Tarleton, Molly M.

    2011-01-01

    Objective: In order to be reimbursed for the care they provide, hospitals in the United States are required to use a standard system to code all discharge diagnoses: the International Classification of Disease, 9th Revision, Clinical Modification (ICD-9). Although ICD-9 codes specific for child maltreatment exist, they do not identify all…

  17. 77 FR 8877 - ICD-9-CM Coordination and Maintenance (C&M) Committee Meeting

    Science.gov (United States)

    2012-02-15

    ...), Classifications and Public Health Data Standards Staff, announces the following meeting. Name: ICD-9-CM... proposed modifications to the International Classification of Diseases, Ninth-Revision, Clinical... Infusion of Glucarpidase ICD-10 Updates: ICD-10 MS-DRG Update ICD-10 HAC Translation List Impact of ICD-10...

  18. The WHO application of ICD-10 to deaths during the perinatal period (ICD-PM) : results from pilot database testing in South Africa and United Kingdom

    NARCIS (Netherlands)

    Allanson, E. R.; Tuncalp, Oe; Gardosi, J.; Pattinson, R. C.; Francis, A.; Vogel, J. P.; Erwich, J. J. H. M.; Flenady, V. J.; Froen, J. F.; Neilson, J.; Quach, A.; Chou, D.; Mathai, M.; Say, L.; Guelmezoglu, A. M.

    2016-01-01

    Objective To apply the World Health Organization (WHO) Application of the International Classification of Diseases, tenth revision (ICD-10) to deaths during the perinatal period: ICD-Perinatal Mortality (ICD-PM) to existing perinatal death databases. Design Retrospective application of ICD-PM.

  19. ICD-11: a comprehensive picture of health, an update on the ICD-ICF joint use initiative.

    Science.gov (United States)

    Selb, Melissa; Kohler, Friedbert; Robinson Nicol, Molly Meri; Riberto, Marcelo; Stucki, Gerold; Kennedy, Cille; Üstün, Bedirhan

    2015-01-01

    This is a follow-up of the special report Towards the joint use of ICD and ICF: A call for contribution, published by the Journal of Rehabilitation Medicine in 2012, which introduced an initiative of using the International Classification of Diseases (ICD) and the International Classification of Functioning, Disability and Health (ICF) in a complementary way in clinical practice. Recognizing the merits of using the ICD and ICF jointly, the World Health Organization (WHO) introduced so-called functioning properties in the ICD-11. The first step in this ICD-ICF joint use initiative revealed 103 rehabilitation-relevant health conditions for which functioning properties were to be identified. Afterwards experts were recruited to identify the functioning properties for the health conditions for which no ICF Core Sets were available and all the functioning properties were integrated in the beta-version of ICD-11. The objective of this special report is to present the outcome of the recruitment and training of the contributing experts, and to provide an update on the current status of identifying functioning properties and their integration in ICD-11. Having functioning properties in the ICD-11 achieves a milestone in depicting health information in an integrated and comprehensive manner. Explicitly identifying functioning properties for specific health conditions further reinforces the importance of acquiring a broader and more meaningful picture of a person's health, and can guide clinical decision-making.

  20. Leveraging the NLM map from SNOMED CT to ICD-10-CM to facilitate adoption of ICD-10-CM.

    Science.gov (United States)

    Cartagena, F Phil; Schaeffer, Molly; Rifai, Dorothy; Doroshenko, Victoria; Goldberg, Howard S

    2015-05-01

    Develop and test web services to retrieve and identify the most precise ICD-10-CM code(s) for a given clinical encounter. Facilitate creation of user interfaces that 1) provide an initial shortlist of candidate codes, ideally visible on a single screen; and 2) enable code refinement. To satisfy our high-level use cases, the analysis and design process involved reviewing available maps and crosswalks, designing the rule adjudication framework, determining necessary metadata, retrieving related codes, and iteratively improving the code refinement algorithm. The Partners ICD-10-CM Search and Mapping Services (PI-10 Services) are SOAP web services written using Microsoft's.NET 4.0 Framework, Windows Communications Framework, and SQL Server 2012. The services cover 96% of the Partners problem list subset of SNOMED CT codes that map to ICD-10-CM codes and can return up to 76% of the 69,823 billable ICD-10-CM codes prior to creation of custom mapping rules. We consider ways to increase 1) the coverage ratio of the Partners problem list subset of SNOMED CT codes and 2) the upper bound of returnable ICD-10-CM codes by creating custom mapping rules. Future work will investigate the utility of the transitive closure of SNOMED CT codes and other methods to assist in custom rule creation and, ultimately, to provide more complete coverage of ICD-10-CM codes. ICD-10-CM will be easier for clinicians to manage if applications display short lists of candidate codes from which clinicians can subsequently select a code for further refinement. The PI-10 Services support ICD-10 migration by implementing this paradigm and enabling users to consistently and accurately find the best ICD-10-CM code(s) without translation from ICD-9-CM. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. A case of appropriate inappropriate device therapy: Hyperkalemia-induced ventricular oversensing

    OpenAIRE

    Oudit, Gavin Y; Cameron, Doug; Harris, Louise

    2008-01-01

    The present case describes a patient who received inappropriate, but potentially life-saving, therapy from her implantable cardioverter defibrillator (ICD) in the setting of acute hyperkalemia (plasma potassium concentration = 8 mM). Hyperkalemia was associated with the development of a slow sinusoidal ventricular tachycardia, at a rate of 100 beats/min to 125 beats/min (610 ms to 480 ms) in a patient who is pacemaker-dependent. There was associated fractionation of the ICD electrogram and T ...

  2. Where Does It Lead? Imaging Features of Cardiovascular Implantable Electronic Devices on Chest Radiograph and CT

    Energy Technology Data Exchange (ETDEWEB)

    Lanzman, Rotem S.; Blondin, Dirk; Furst, Gunter; Scherer, Axel; R Miese, Falk; Kroepil, Patric [University of Duesseldorf, Medical Faculty, 40225 Duesseldorf (Germany); Winter, Joachim [University Hospital Duesseldorf, 40225 Duesseldorf (Germany); Abbara, Suhny [Massachusetts General Hospital, Boston, MA (US)

    2011-10-15

    Pacemakers and implantable cardioverter defibrillators (ICDs) are being increasingly employed in patients suffering from cardiac rhythm disturbances. The principal objective of this article is to familiarize radiologists with pacemakers and ICDs on chest radiographs and CT scans. Therefore, the preferred lead positions according to pacemaker types and anatomic variants are introduced in this study. Additionally, the imaging features of incorrect lead positions and defects, as well as complications subsequent to pacemaker implantation are demonstrated herein.

  3. Where Does It Lead? Imaging Features of Cardiovascular Implantable Electronic Devices on Chest Radiograph and CT

    International Nuclear Information System (INIS)

    Lanzman, Rotem S.; Blondin, Dirk; Furst, Gunter; Scherer, Axel; R Miese, Falk; Kroepil, Patric; Winter, Joachim; Abbara, Suhny

    2011-01-01

    Pacemakers and implantable cardioverter defibrillators (ICDs) are being increasingly employed in patients suffering from cardiac rhythm disturbances. The principal objective of this article is to familiarize radiologists with pacemakers and ICDs on chest radiographs and CT scans. Therefore, the preferred lead positions according to pacemaker types and anatomic variants are introduced in this study. Additionally, the imaging features of incorrect lead positions and defects, as well as complications subsequent to pacemaker implantation are demonstrated herein.

  4. Training and support to improve ICD coding quality: A controlled ...

    African Journals Online (AJOL)

    [1] In response to this challenge, the Western Cape Government: Health (WCGH) ... commit to costly, time-consuming accredited ICD coding courses, although ..... being blinded to the retrospective 'assignment' of patients to the intervention ...

  5. Severity of depressive episodes according to ICD-10

    DEFF Research Database (Denmark)

    Kessing, Lars Vedel

    2004-01-01

    BACKGROUND: The ICD-10 categorisation of severity of depression into mild, moderate and severe depressive episodes has not been validated. AIMS: To validate the ICD-10 categorisation of severity of depression by estimating its predictive ability on the course of illness and suicidal outcome. METHOD......: All psychiatric in-patients in Denmark who had received a diagnosis of a single depressive episode at their first discharge between 1994 and 1999 were identified. The risk of relapse and the risk of suicide were compared for patients discharged with an ICD-10 diagnosis of a single mild, moderate...... or severe depressive episode. RESULTS: At their first discharge, 1103 patients had an ICD-10 diagnosis of mild depressive episode, 3182 had a diagnosis of moderate depressive episode and 2914 had a diagnosis of severe depressive episode. The risk of relapse and the risk of suicide were significantly...

  6. The challenges and possibilities of public access defibrillation.

    Science.gov (United States)

    Ringh, M; Hollenberg, J; Palsgaard-Moeller, T; Svensson, L; Rosenqvist, M; Lippert, F K; Wissenberg, M; Malta Hansen, C; Claesson, A; Viereck, S; Zijlstra, J A; Koster, R W; Herlitz, J; Blom, M T; Kramer-Johansen, J; Tan, H L; Beesems, S G; Hulleman, M; Olasveengen, T M; Folke, F

    2018-03-01

    Out-of-hospital cardiac arrest (OHCA) is a major health problem that affects approximately four hundred and thousand patients annually in the United States alone. It is a major challenge for the emergency medical system as decreased survival rates are directly proportional to the time delay from collapse to defibrillation. Historically, defibrillation has only been performed by physicians and in-hospital. With the development of automated external defibrillators (AEDs), rapid defibrillation by nonmedical professionals and subsequently by trained or untrained lay bystanders has become possible. Much hope has been put to the concept of Public Access Defibrillation with a massive dissemination of public available AEDs throughout most Western countries. Accordingly, current guidelines recommend that AEDs should be deployed in places with a high likelihood of OHCA. Despite these efforts, AED use is in most settings anecdotal with little effect on overall OHCA survival. The major reasons for low use of public AEDs are that most OHCAs take place outside high incidence sites of cardiac arrest and that most OHCAs take place in residential settings, currently defined as not suitable for Public Access Defibrillation. However, the use of new technology for identification and recruitment of lay bystanders and nearby AEDs to the scene of the cardiac arrest as well as new methods for strategic AED placement redefines and challenges the current concept and definitions of Public Access Defibrillation. Existing evidence of Public Access Defibrillation and knowledge gaps and future directions to improve outcomes for OHCA are discussed. In addition, a new definition of the different levels of Public Access Defibrillation is offered as well as new strategies for increasing AED use in the society. © 2018 The Association for the Publication of the Journal of Internal Medicine.

  7. [ILCOR recommendation on signage of automated external defibrillators (AEDs)].

    Science.gov (United States)

    Truhlár, A

    2010-05-01

    Early defibrillation is a determinant of survival in both out-of-hospital and in-hospital cardiac arrests from ventricular fibrillation and pulseless ventricular tachycardia. The review summarizes importance of early defibrillation with automated external defibrillators (AED) and presents the International Liaison Committee on Resuscitation (ILCOR) recommendation for universal AED sign. The aim of the recommendation is to unify the AED signs worldwide and to spread the knowledge of this. The public in general, but healthcare professionals particularly, should be able to recognize AED location and use the device immediately in case of cardiac arrest.

  8. Genoplivning med automatisk ekstern defibrillator på hospital

    DEFF Research Database (Denmark)

    Løfgren, Bo; Wahlgreen, Claus; Hoffmann, Anne Mette

    2009-01-01

    Early defibrillation is a determinant of survival in cardiac arrest. We report a Danish case of successful in-hospital resuscitation using an automated external defibrillator (AED). This case illustrates important aspects of implementation of in-hospital use of an AED, i.e. location of the AED......, education of the staff, systematic registration and data collection and technical aspects of AED use. If in-hospital AED implementation is carefully executed, its use may provide a safe and effective way of obtaining early defibrillation. Udgivelsesdato: 2009-Jan-26...

  9. Implementation and impact of ICD-10 (Part II).

    Science.gov (United States)

    Rahmathulla, Gazanfar; Deen, H Gordon; Dokken, Judith A; Pirris, Stephen M; Pichelmann, Mark A; Nottmeier, Eric W; Reimer, Ronald; Wharen, Robert E

    2014-01-01

    The transition from the International Classification of Disease-9(th) clinical modification to the new ICD-10 was all set to occur on 1 October 2015. The American Medical Association has previously been successful in delaying the transition by over 10 years and has been able to further postpone its introduction to 2015. The new system will overcome many of the limitations present in the older version, thus paving the way to more accurate capture of clinical information. The benefits of the new ICD-10 system include improved quality of care, potential cost savings, reduction of unpaid claims, and improved tracking of healthcare data. The areas where challenges will be evident include planning and implementation, the cost to transition, a shortage of qualified coders, training and education of the healthcare workforce, and a loss of productivity when this occurs. The impacts include substantial costs to the healthcare system, but the projected long-term savings and benefits will be significant. Improved fraud detection, accurate data entry, ability to analyze cost benefits with procedures, and enhanced quality outcome measures are the most significant beneficial factors with this change. The present Current Procedural Terminology and Healthcare Common Procedure Coding System code sets will be used for reporting ambulatory procedures in the same manner as they have been. ICD-10-PCS will replace ICD-9 procedure codes for inpatient hospital services. The ICD-10-CM will replace the clinical code sets. Our article will focus on the challenges to execution of an ICD change and strategies to minimize risk while transitioning to the new system. With the implementation deadline gradually approaching, spine surgery practices that include multidisciplinary health specialists have to anticipate and prepare for the ICD change in order to mitigate risk. Education and communication is the key to this process in spine practices.

  10. Can machine learning complement traditional medical device surveillance? A case-study of dual-chamber implantable cardioverter–defibrillators

    Directory of Open Access Journals (Sweden)

    Ross JS

    2017-08-01

    Full Text Available Joseph S Ross,1–4 Jonathan Bates,4 Craig S Parzynski,4 Joseph G Akar,4,5 Jeptha P Curtis,4,5 Nihar R Desai,4,5 James V Freeman,4,5 Ginger M Gamble,4 Richard Kuntz,6 Shu-Xia Li,4 Danica Marinac-Dabic,7 Frederick A Masoudi,8 Sharon-Lise T Normand,9,10 Isuru Ranasinghe,11 Richard E Shaw,12 Harlan M Krumholz2–5 1Section of General Medicine, Department of Medicine, 2Robert Wood Johnson Foundation Clinical Scholars Program, Yale School of Medicine, 3Department of Health Policy and Management, Yale School of Public Health, 4Center for Outcomes Research and Evaluation, Yale–New Haven Hospital, 5Section of Cardiovascular Medicine, Department of Medicine, Yale School of Medicine, New Haven, CT, 6Medtronic Inc, Minneapolis, MN, 7Division of Epidemiology, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, MD, 8Division of Cardiology, Department of Medicine, University of Colorado, Aurora, CO, 9Department of Health Care Policy, Harvard Medical School, 10Department of Biostatistics, Harvard TH Chan School of Public Health, Boston, MA, USA; 11Discipline of Medicine, University of Adelaide, Adelaide, SA, Australia; 12Department of Clinical Informatics, California Pacific Medical Center, San Francisco, CA, USA Background: Machine learning methods may complement traditional analytic methods for medical device surveillance.Methods and results: Using data from the National Cardiovascular Data Registry for implantable cardioverter–defibrillators (ICDs linked to Medicare administrative claims for longitudinal follow-up, we applied three statistical approaches to safety-signal detection for commonly used dual-chamber ICDs that used two propensity score (PS models: one specified by subject-matter experts (PS-SME, and the other one by machine learning-based selection (PS-ML. The first approach used PS-SME and cumulative incidence (time-to-event, the second approach used PS-SME and cumulative risk (Data Extraction and

  11. The effect of ICD programming on inappropriate and appropriate ICD Therapies in ischemic and nonischemic cardiomyopathy: the MADIT-RIT trial.

    Science.gov (United States)

    Sedláček, Kamil; Ruwald, Anne-Christine; Kutyifa, Valentina; McNitt, Scott; Thomsen, Poul Erik Bloch; Klein, Helmut; Stockburger, Martin; Wichterle, Dan; Merkely, Bela; DE LA Concha, Joaquin Fernandez; Swissa, Moshe; Zareba, Wojciech; Moss, Arthur J; Kautzner, Josef; Ruwald, Martin H

    2015-04-01

    The MADIT-RIT trial demonstrated reduction of inappropriate and appropriate ICD therapies and mortality by high-rate cut-off and 60-second-delayed VT therapy ICD programming in patients with a primary prophylactic ICD indication. The aim of this analysis was to study effects of MADIT-RIT ICD programming in patients with ischemic and nonischemic cardiomyopathy. First and total occurrences of both inappropriate and appropriate ICD therapies were analyzed by multivariate Cox models in 791 (53%) patients with ischemic and 707 (47%) patients with nonischemic cardiomyopathy. Patients with ischemic and nonischemic cardiomyopathy had similar incidence of first inappropriate (9% and 11%, P = 0.21) and first appropriate ICD therapy (11.6% and 14.1%, P = 0.15). Patients with ischemic cardiomyopathy had higher mortality rate (6.1% vs. 3.3%, P = 0.01). MADIT-RIT high-rate cut-off (arm B) and delayed VT therapy ICD programming (arm C) compared with conventional (arm A) ICD programming were associated with a significant risk reduction of first inappropriate and appropriate ICD therapy in patients with ischemic and nonischemic cardiomyopathy (HR range 0.11-0.34, P programming and delayed VT therapy ICD programming in both ischemic and nonischemic cardiomyopathy patients. High-rate cut-off and delayed VT therapy ICD programming are associated with significant reduction in first and total inappropriate and appropriate ICD therapy in patients with ischemic and nonischemic cardiomyopathy. © 2014 Wiley Periodicals, Inc.

  12. Wide variation in cardiopulmonary resuscitation interruption intervals among commercially available automated external defibrillators may affect survival despite high defibrillation efficacy.

    Science.gov (United States)

    Snyder, David; Morgan, Carl

    2004-09-01

    Recent studies have associated interruptions of cardiopulmonary resuscitation imposed by automated external defibrillators (AEDs) with poor resuscitation outcome. In particular, the "hands-off" interval between precordial compressions and subsequent defibrillation shock has been implicated. We sought to determine the range of variation among current-generation AEDs with respect to this characteristic. Seven AEDs from six manufacturers were characterized via stopwatch and arrhythmia simulator with respect to the imposed hands-off interval. All AEDs were equipped with new batteries, and measurements were repeated five times for each AED. A wide variation in the hands-off interval between precordial compressions and shock delivery was observed, ranging from 5.2 to 28.4 secs, with only one AED achieving an interruption of <10 secs. Laboratory and clinical data suggest that this range of variation could be responsible for a more than two-fold variation in patient resuscitation success, an effect that far exceeds any defibrillation efficacy differences that may hypothetically exist. In addition to defibrillation waveform and dose, researchers should consider the hands-off cardiopulmonary resuscitation interruption interval between cardiopulmonary resuscitation and subsequent defibrillation shock to be an important covariate of outcome in resuscitation studies. Defibrillator design should minimize this interval to avoid potential adverse consequences on patient survival.

  13. Body-focused repetitive behavior disorders in ICD-11

    Directory of Open Access Journals (Sweden)

    Jon E. Grant

    2014-01-01

    Full Text Available This article addresses the question of how body-focused repetitive behavior disorders (e.g., trichotillomania and skin-picking disorder should be characterized in ICD-11. The article reviews the historical nosology of the two disorders and the current approaches in DSM-5 and ICD-10. Although data are limited and mixed regarding the optimal relationship between body-focused repetitive behavior disorders and nosological categories, these conditions should be included within the obsessive-compulsive and related disorders category, as this is how most clinicians see these behaviors, and as this may optimize clinical utility. The descriptions of these disorders should largely mirror those in DSM-5, given the evidence from recent field surveys. The recommendations regarding ICD-11 and body-focused repetitive behavior disorders should promote the global identification and treatment of these conditions in primary care settings.

  14. Deriving ICD-11 personality disorder domains from dsm-5 traits

    DEFF Research Database (Denmark)

    Bach, B; Sellbom, M; Kongerslev, M

    2017-01-01

    OBJECTIVE: The personality disorder domains proposed for the ICD-11 comprise Negative Affectivity, Detachment, Dissociality, Disinhibition, and Anankastia, which are reasonably concordant with the higher-order trait domains in the Alternative DSM-5 Model for Personality Disorders. METHOD: We...... replication sample (N = 637) completed the Personality Inventory for DSM-5 (PID-5). Sixteen PID-5 traits were designated to cover features of the ICD-11 trait domains. RESULTS: Exploratory structural equation modeling (ESEM) analyzes showed that the designated traits were meaningfully organized......-11 personality disorder domains can be accurately described using designated traits from the DSM-5 personality trait system. A scoring algorithm for the ICD-11 personality disorder domains is provided in appendix....

  15. ICD-11 (JLMMS) and SCT Inter-Operation.

    Science.gov (United States)

    Mamou, Marzouk; Rector, Alan; Schulz, Stefan; Campbell, James; Solbrig, Harold; Rodrigues, Jean-Marie

    2016-01-01

    The goal of this work is to contribute to a smooth and semantically sound inter-operability between the ICD-11 (International Classification of Diseases-11th revision Joint Linearization for Mortality, Morbidity and Statistics) and SNOMED CT (SCT). To guarantee such inter-operation between a classification, characterized by a single hierarchy of mutually exclusive and exhaustive classes, as is the JLMMS successor of ICD-10 on the one hand, and the multi-hierarchical, ontology-based clinical terminology SCT on the other hand, we use ontology axioms that logically express generalizable truths. This is expressed by the compositional grammar of SCT, together with queries on axiomsof SCT. We test the feasibility of the method on the circulatory chapter of ICD-11 JLMMS and present limitations and results.

  16. Comparison of DSM-5 and proposed ICD-11 criteria for PTSD with DSM-IV and ICD-10: changes in PTSD prevalence in military personnel.

    Science.gov (United States)

    Kuester, Annika; Köhler, Kai; Ehring, Thomas; Knaevelsrud, Christine; Kober, Louisa; Krüger-Gottschalk, Antje; Schäfer, Ingo; Schellong, Julia; Wesemann, Ulrich; Rau, Heinrich

    2017-01-01

    Background: Recently, changes have been introduced to the diagnostic criteria for posttraumatic stress disorder (PTSD) according to the Diagnostic and Statistical Manual of Mental Disorders (DSM) and the International Classification of Diseases (ICD). Objectives: This study investigated the effect of the diagnostic changes made from DSM-IV to DSM-5 and from ICD-10 to the proposed ICD-11. The concordance of provisional PTSD prevalence between the diagnostic criteria was examined in a convenience sample of 100 members of the German Armed Forces. Method: Based on questionnaire measurements, provisional PTSD prevalence was assessed according to DSM-IV, DSM-5, ICD-10, and proposed ICD-11 criteria. Consistency of the diagnostic status across the diagnostic systems was statistically evaluated. Results: Provisional PTSD prevalence was the same for DSM-IV and DSM-5 (both 56%) and comparable under DSM-5 versus ICD-11 proposal (48%). Agreement between DSM-IV and DSM-5, and between DSM-5 and the proposed ICD-11, was high (both p  DSM-IV, DSM-5, and proposed ICD-11. This supports the assumption of a set of PTSD core symptoms as suggested in the ICD-11 proposal, when at the same time a satisfactory concordance between ICD-11 proposal and DSM was given. The finding of increased provisional PTSD prevalence under ICD-11 proposal in contrast to ICD-10 can be of guidance for future epidemiological research on PTSD prevalence, especially concerning further investigations on the impact, appropriateness, and usefulness of the time criterion included in ICD-10 versus the consequences of its deletion as proposed for ICD-11.

  17. Comparison of DSM-5 and proposed ICD-11 criteria for PTSD with DSM-IV and ICD-10: changes in PTSD prevalence in military personnel

    Science.gov (United States)

    Kuester, Annika; Köhler, Kai; Ehring, Thomas; Knaevelsrud, Christine; Kober, Louisa; Krüger-Gottschalk, Antje; Schäfer, Ingo; Schellong, Julia; Wesemann, Ulrich; Rau, Heinrich

    2017-01-01

    ABSTRACT Background: Recently, changes have been introduced to the diagnostic criteria for posttraumatic stress disorder (PTSD) according to the Diagnostic and Statistical Manual of Mental Disorders (DSM) and the International Classification of Diseases (ICD). Objectives:This study investigated the effect of the diagnostic changes made from DSM-IV to DSM-5 and from ICD-10 to the proposed ICD-11. The concordance of provisional PTSD prevalence between the diagnostic criteria was examined in a convenience sample of 100 members of the German Armed Forces. Method: Based on questionnaire measurements, provisional PTSD prevalence was assessed according to DSM-IV, DSM-5, ICD-10, and proposed ICD-11 criteria. Consistency of the diagnostic status across the diagnostic systems was statistically evaluated. Results: Provisional PTSD prevalence was the same for DSM-IV and DSM-5 (both 56%) and comparable under DSM-5 versus ICD-11 proposal (48%). Agreement between DSM-IV and DSM-5, and between DSM-5 and the proposed ICD-11, was high (both p DSM-5, and proposed ICD-11. This supports the assumption of a set of PTSD core symptoms as suggested in the ICD-11 proposal, when at the same time a satisfactory concordance between ICD-11 proposal and DSM was given. The finding of increased provisional PTSD prevalence under ICD-11 proposal in contrast to ICD-10 can be of guidance for future epidemiological research on PTSD prevalence, especially concerning further investigations on the impact, appropriateness, and usefulness of the time criterion included in ICD-10 versus the consequences of its deletion as proposed for ICD-11. PMID:29163862

  18. Out-of-hospital cardiac arrest: Probability of bystander defibrillation relative to distance to nearest automated external defibrillator.

    Science.gov (United States)

    Sondergaard, Kathrine B; Hansen, Steen Moller; Pallisgaard, Jannik L; Gerds, Thomas Alexander; Wissenberg, Mads; Karlsson, Lena; Lippert, Freddy K; Gislason, Gunnar H; Torp-Pedersen, Christian; Folke, Fredrik

    2018-03-01

    Despite wide dissemination of automated external defibrillators (AEDs), bystander defibrillation rates remain low. We aimed to investigate how route distance to the nearest accessible AED was associated with probability of bystander defibrillation in public and residential locations. We used data from the nationwide Danish Cardiac Arrest Registry and the Danish AED Network to identify out-of-hospital cardiac arrests and route distances to nearest accessible registered AED during 2008-2013. The association between route distance and bystander defibrillation was described using restricted cubic spline logistic regression. We included 6971 out-of-hospital cardiac arrest cases. The proportion of arrests according to distance in meters (≤100, 101-200, >200) to the nearest accessible AED was: 4.6% (n=320), 5.3% (n=370), and 90.1% (n=6281), respectively. For cardiac arrests in public locations, the probability of bystander defibrillation at 0, 100 and 200m from the nearest AED was 35.7% (95% confidence interval 28.0%-43.5%), 21.3% (95% confidence interval 17.4%-25.2%), and 13.7% (95% confidence interval 10.1%-16.8%), respectively. The corresponding numbers for cardiac arrests in residential locations were 7.0% (95% confidence interval -2.1%-16.1%), 1.5% (95% confidence interval 0.002%-2.8%), and 0.9% (95% confidence interval 0.0005%-1.7%), respectively. In public locations, the probability of bystander defibrillation decreased rapidly within the first 100m route distance from cardiac arrest to nearest accessible AED whereas the probability of bystander defibrillation was low for all distances in residential areas. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. ICD-11 trauma questionnaires for PTSD and complex PTSD

    DEFF Research Database (Denmark)

    Dokkedahl, Sarah Bøgelund; Oboke, Henry; Ovuga, Emilio

    2015-01-01

    Objectives: ICD-11 is expected to introduce a new diagnosis of C-PTSD, along with a revision of the current PTSD diagnosis. Are the suggested diagnostic tools for PTSD and C-PTSD valid in a developing country? Method: The tools have been tested on former abducted and regular civilians in northern...

  20. Psychotic disorders in DSM-5 and ICD-11.

    Science.gov (United States)

    Biedermann, Falko; Fleischhacker, W Wolfgang

    2016-08-01

    The Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) was published by the American Psychiatric Association (APA) in 2013, and the Work Group on the Classification of Psychotic disorders (WGPD), installed by the World Health Organization (WHO), is expected to publish the new chapter about schizophrenia and other primary psychotic disorders in 2017. We reviewed the available literature to summarize the major changes, innovations, and developments of both manuals. If available and possible, we outline the theoretical background behind these changes. Due to the fact that the development of ICD-11 has not yet been completed, the details about ICD-11 are still proposals under ongoing revision. In this ongoing process, they may be revised and therefore have to be seen as proposals. DSM-5 has eliminated schizophrenia subtypes and replaced them with a dimensional approach based on symptom assessments. ICD-11 will most likely go in a similar direction, as both manuals are planned to be more harmonized, although some differences will remain in details and the conceptual orientation. Next to these modifications, ICD-11 will provide a transsectional diagnostic criterion for schizoaffective disorders and a reorganization of acute and transient psychotic and delusional disorders. In this manuscript, we will compare the 2 classification systems.

  1. Clashing Diagnostic Approaches: DSM-ICD versus RDoC

    Science.gov (United States)

    Lilienfeld, Scott O.; Treadway, Michael T.

    2016-01-01

    Since at least the middle of the past century, one overarching model of psychiatric classification, namely, that of the Diagnostic and Statistical Manual of Mental Disorders and International Classification of Diseases (DSM-ICD), has reigned supreme. This DSM-ICD approach embraces an Aristotelian view of mental disorders as largely discrete entities that are characterized by distinctive signs, symptoms, and natural histories. Over the past several years, however, a competing vision, namely, the Research Domain Criteria (RDoC) initiative launched by the National Institute of Mental Health, has emerged in response to accumulating anomalies within the DSM-ICD system. In contrast to DSM-ICD, RDoC embraces a Galilean view of psychopathology as the product of dysfunctions in neural circuitry. RDoC appears to be a valuable endeavor that holds out the long-term promise of an alternative system of mental illness classification. We delineate three sets of pressing challenges – conceptual, methodological, and logistical/pragmatic – that must be addressed for RDoC to realize its scientific potential, and conclude with a call for further research, including investigation of a rapprochement between Aristotelian and Galilean approaches to psychiatric classification. PMID:26845519

  2. Uniform pacemaker and ICD information system in the Netherlands

    NARCIS (Netherlands)

    Cam, H; Wa, D; Callaos, N; Farsi, D; EshaghianWilner, M; Hanratty, T; Rishe, N

    2003-01-01

    The Central Pacemaker Patient Registry (CPPR) in the Netherlands (founded in 1977) collects information of pacemaker patients from all 110 Dutch hospitals. It contains data of over 98.000 patients, 118.500 pacemakers, 1.950 ICD's and 131.000 leads. Initially data was entered manually. As local

  3. Hoarding disorder: a new diagnostic category in ICD-11?

    Directory of Open Access Journals (Sweden)

    Leonardo F. Fontenelle

    2014-01-01

    Full Text Available Despite the long-held view that hoarding is a symptom of both obsessive-compulsive disorder and obsessive-compulsive personality disorder, increased evidence has emerged during the last 20 years suggesting that hoarding represents a distinct form of psychopathology. This study reflects the discussions on the nosological status of hoarding carried out by the WHO ICD-11 Working Group on the Classification of Obsessive-Compulsive and Related Disorders. The distinctiveness of hoarding is based on its having core symptoms that differ from those of other disorders, as well as distinctive neurobiological correlates and treatment responses. Furthermore, data showing the clinical utility, global applicability, and appropriateness of the concept of hoarding disorder outside specialty mental health settings suggest that this condition should be included in ICD-11. Finally, given the focus of ICD-11 on primary care and public health, the Working Group suggests that poor insight and severe domestic squalor may be considered as specifiers for hoarding disorder in ICD-11.

  4. Use a defibrillator, save a life

    CERN Multimedia

    Joannah Caborn Wengler

    2012-01-01

    With the work for Long Shutdown 1 looming on the horizon, the CERN Fire Brigade is anticipating a heavy workload: more people working at CERN means more call-outs. So the more trained first-aiders around to help out before the paramedics arrive, the better. Would you know what to do in a medical emergency?   It could happen at any time: two colleagues are having a coffee at work, when one suddenly clutches his or her chest and falls to the floor unconscious. What would you do? Run to find a first-aider? Call the ambulance and wait, finishing your coffee? Neither response is entirely correct. On Monday 11 June in Building 40 the CMS safety group, in collaboration with the Fire Brigade and the Medical Service, demonstrated the recommended, potentially life-saving response to cardiac arrest (see the video), including the correct use of a defibrillator, ten of which were recently installed in key CERN locations (the Bulletin reported).     “In countries where...

  5. Prognostic value of microvolt T-wave alternans in a real-world ICD population. Twente ICD Cohort Studie (TICS)

    NARCIS (Netherlands)

    Kraaier, K.; Olimulder, M. A. G. M.; van Dessel, P. F. H. M.; Wilde, A. A. M.; Scholten, M. F.

    2014-01-01

    Introduction Survival benefit from ICD implantation is relatively low in primary prevention patients. Better patient selection is important to maintain maximum survival benefit while reducing the number of unnecessary implants. Microvolt T-wave alternans (MTWA) is a promising risk marker. In this

  6. The challenges and possibilities of public access defibrillation

    DEFF Research Database (Denmark)

    Ringh, Mattias; Hollenberg, Jacob; Palsgaard-Moeller, Thea

    2018-01-01

    . Much hope has been put to the concept of Public Access Defibrillation with a massive dissemination of public available AEDs throughout most western countries. Accordingly, current guidelines recommend that AEDs should be deployed in places with a high likelihood of OHCA. Despite these efforts, AED use...... is in most settings anecdotal with little effect on overall OHCA survival. The major reasons for low use of public AEDs are that most OHCA take place outside high incidence sites of cardiac arrest and that most OHCAs take place in residential settings, currently defined as not suitable for Public Access...... Defibrillation. However, the use of new technology for identification and recruitment of lay bystanders and nearby AEDs to the scene of the cardiac arrest as well as new methods for strategic AED placement redefines and challenges the current concept and definitions of Public Access Defibrillation. Existing...

  7. Praehospital-hjertestopbehandling med semiautomatisk defibrillator--Heartstart 2000

    DEFF Research Database (Denmark)

    Fonsmark, L; Sandøe, E; Kastrup, J

    1989-01-01

    %. No practical problems of note occurred in connection with employment of the defibrillator. The ambulance staffs underwent six hours of training and this appeared to be adequate. It is concluded that Heartstart 2000 functions well and effectively in connection with revival of patients with cardiac arrest......In order to test the efficacy of a semiautomatic defibrillator (Heartstart 2000) in connection with cardiac arrest outside hospital, the apparatus was installed in two of the ambulances belonging to the Copenhagen Fire Service. The ambulance district involved was also equipped with an ambulance...... staffed by a doctor. A total of 48 patients with cardiac arrest were found and 16 of these had ventricular fibrillation. Six of the 16 patients have since been discharged from hospital (37.5%). The defibrillator had a high diagnostic certainty with a sensitivity of 96.5% and a specificity of 100...

  8. Praehospital-hjertestopbehandling med semiautomatisk defibrillator--Heartstart 2000

    DEFF Research Database (Denmark)

    Fonsmark, L; Sandøe, E; Kastrup, J

    1989-01-01

    staffed by a doctor. A total of 48 patients with cardiac arrest were found and 16 of these had ventricular fibrillation. Six of the 16 patients have since been discharged from hospital (37.5%). The defibrillator had a high diagnostic certainty with a sensitivity of 96.5% and a specificity of 100......%. No practical problems of note occurred in connection with employment of the defibrillator. The ambulance staffs underwent six hours of training and this appeared to be adequate. It is concluded that Heartstart 2000 functions well and effectively in connection with revival of patients with cardiac arrest...

  9. An administrative data merging solution for dealing with missing data in a clinical registry: adaptation from ICD-9 to ICD-10

    Directory of Open Access Journals (Sweden)

    Galbraith P Diane

    2008-01-01

    Full Text Available Abstract Background We have previously described a method for dealing with missing data in a prospective cardiac registry initiative. The method involves merging registry data to corresponding ICD-9-CM administrative data to fill in missing data 'holes'. Here, we describe the process of translating our data merging solution to ICD-10, and then validating its performance. Methods A multi-step translation process was undertaken to produce an ICD-10 algorithm, and merging was then implemented to produce complete datasets for 1995–2001 based on the ICD-9-CM coding algorithm, and for 2002–2005 based on the ICD-10 algorithm. We used cardiac registry data for patients undergoing cardiac catheterization in fiscal years 1995–2005. The corresponding administrative data records were coded in ICD-9-CM for 1995–2001 and in ICD-10 for 2002–2005. The resulting datasets were then evaluated for their ability to predict death at one year. Results The prevalence of the individual clinical risk factors increased gradually across years. There was, however, no evidence of either an abrupt drop or rise in prevalence of any of the risk factors. The performance of the new data merging model was comparable to that of our previously reported methodology: c-statistic = 0.788 (95% CI 0.775, 0.802 for the ICD-10 model versus c-statistic = 0.784 (95% CI 0.780, 0.790 for the ICD-9-CM model. The two models also exhibited similar goodness-of-fit. Conclusion The ICD-10 implementation of our data merging method performs as well as the previously-validated ICD-9-CM method. Such methodological research is an essential prerequisite for research with administrative data now that most health systems are transitioning to ICD-10.

  10. Subtypes of depressive episodes according to ICD-10

    DEFF Research Database (Denmark)

    Kessing, Lars Vedel

    2003-01-01

    a period from 1994 to 1999 were identified. The risk of relapse leading to readmission and the risk of committing suicide were compared for patients discharged with an ICD-10 diagnosis of a single depressive episode with and without melancholic syndrome and for patients with and without psychotic symptoms......BACKGROUND: The long-term predictive ability of the ICD-10 subtypes of depression with melancholic syndrome and depression with psychosis has not been investigated. SAMPLING AND METHODS: All patients in Denmark who had a diagnosis of a single depressive episode at their first ever discharge during......, respectively. RESULTS: In all, 1,639 patients had a diagnosis of depressive episode without psychotic symptoms, 1,275 patients a diagnosis with psychotic symptoms, 293 a diagnosis without melancholic syndrome, and 248 a diagnosis with melancholic symptoms at first discharge. The risk of relapse leading...

  11. Identifying priorities in methodological research using ICD-9-CM and ICD-10 administrative data: report from an international consortium

    Directory of Open Access Journals (Sweden)

    Ma Jin

    2006-06-01

    Full Text Available Abstract Background Health administrative data are frequently used for health services and population health research. Comparative research using these data has been facilitated by the use of a standard system for coding diagnoses, the International Classification of Diseases (ICD. Research using the data must deal with data quality and validity limitations which arise because the data are not created for research purposes. This paper presents a list of high-priority methodological areas for researchers using health administrative data. Methods A group of researchers and users of health administrative data from Canada, the United States, Switzerland, Australia, China and the United Kingdom came together in June 2005 in Banff, Canada to discuss and identify high-priority methodological research areas. The generation of ideas for research focussed not only on matters relating to the use of administrative data in health services and population health research, but also on the challenges created in transitioning from ICD-9 to ICD-10. After the brain-storming session, voting took place to rank-order the suggested projects. Participants were asked to rate the importance of each project from 1 (low priority to 10 (high priority. Average ranks were computed to prioritise the projects. Results Thirteen potential areas of research were identified, some of which represented preparatory work rather than research per se. The three most highly ranked priorities were the documentation of data fields in each country's hospital administrative data (average score 8.4, the translation of patient safety indicators from ICD-9 to ICD-10 (average score 8.0, and the development and validation of algorithms to verify the logic and internal consistency of coding in hospital abstract data (average score 7.0. Conclusion The group discussions resulted in a list of expert views on critical international priorities for future methodological research relating to health

  12. Impact of shocks on mortality in patients with ischemic or dilated cardiomyopathy and defibrillators implanted for primary prevention.

    Directory of Open Access Journals (Sweden)

    Florian Streitner

    Full Text Available BACKGROUND: Emerging interest is seen in the paradox of defibrillator shocks for ventricular tachyarrhythmia and increased mortality risk. Particularly in patients with dilated cardiomyopathy (DCM, the prognostic importance of shocks is unclear. The purpose of this study was to compare the outcome after shocks in patients with ischemic cardiomyopathy (ICM or DCM and defibrillators (ICD implanted for primary prevention. METHODS AND RESULTS: Data of 561 patients were analyzed (mean age 68.6±10.6 years, mean left ventricular ejection fraction 28.6±7.3%. During a median follow-up of 49.3 months, occurrence of device therapies and all-cause mortality were recorded. 74 out of 561 patients (13.2% experienced ≥1 appropriate and 51 out of 561 patients (9.1% ≥1 inappropriate shock. All-cause mortality was 24.2% (136 out of 561 subjects. Appropriate shock was associated with a trend to higher mortality in the overall patient population (HR 1.48, 95% CI 0.96-2.28, log rank p = 0.072. The effect was significant in ICM patients (HR 1.61, 95% CI 1.00-2.59, log rank p = 0.049 but not in DCM patients (HR 1.03, 95% CI 0.36-2.96, log rank p = 0.96. Appropriate shocks occurring before the median follow-up revealed a much stronger impact on mortality (HR for the overall patient population 2.12, 95% CI 1.24-3.63, p = 0.005. The effect was driven by ICM patients (HR 2.48, 95% CI 1.41-4.37, p = 0.001, as appropriate shocks again did not influence survival of DCM patients (HR 0.63, 95% CI 0.083-4.75, p = 0.65. Appropriate shocks occurring after the median follow-up and inappropriate shocks occurring at any time revealed no impact on survival in any of the groups (p = ns. CONCLUSION: Appropriate shocks are associated with reduced survival in patients with ICM but not in patients with DCM and ICDs implanted for primary prevention. Furthermore, the negative effect of appropriate shocks on survival in ICM patients is only evident within the

  13. Testing of Anesthesia Machines and Defibrillators in Healthcare Institutions.

    Science.gov (United States)

    Gurbeta, Lejla; Dzemic, Zijad; Bego, Tamer; Sejdic, Ervin; Badnjevic, Almir

    2017-09-01

    To improve the quality of patient treatment by improving the functionality of medical devices in healthcare institutions. To present the results of the safety and performance inspection of patient-relevant output parameters of anesthesia machines and defibrillators defined by legal metrology. This study covered 130 anesthesia machines and 161 defibrillators used in public and private healthcare institutions, during a period of two years. Testing procedures were carried out according to international standards and legal metrology legislative procedures in Bosnia and Herzegovina. The results show that in 13.84% of tested anesthesia machine and 14.91% of defibrillators device performance is not in accordance with requirements and should either have its results be verified, or the device removed from use or scheduled for corrective maintenance. Research emphasizes importance of independent safety and performance inspections, and gives recommendations for the frequency of inspection based on measurements. Results offer implications for adequacy of preventive and corrective maintenance performed in healthcare institutions. Based on collected data, the first digital electronical database of anesthesia machines and defibrillators used in healthcare institutions in Bosnia and Herzegovina is created. This database is a useful tool for tracking each device's performance over time.

  14. Hvor er den automatiske eksterne defibrillator? Udvikling og uddannelse

    DEFF Research Database (Denmark)

    Løfgren, Bo; Grove, Erik; Krarup, Niels Henrik

    2009-01-01

    The International Liaison Committee on Resuscitation has presented a universal sign to indicate the presence of automated external defibrillators (AED). To disseminate the knowledge of this important signage, a review in a Danish context is presented. It is essential that the public in general...

  15. Pacemakers and Implantable Defibrillators: MedlinePlus Health Topic

    Science.gov (United States)

    ... ClinicalTrials.gov: Pacemaker, Artificial (National Institutes of Health) Journal Articles References and abstracts from MEDLINE/PubMed (National ... Leadless Cardiac Pacemakers: The Next Evolution in Pacemaker Technology. ... on Pacemakers and Implantable Defibrillators is the National Heart, Lung, and Blood Institute Other Languages Find health information in languages other than English on Pacemakers and ...

  16. A self-report measure for the ICD-11 dimensional trait model proposal: The personality inventory for ICD-11.

    Science.gov (United States)

    Oltmanns, Joshua R; Widiger, Thomas A

    2018-02-01

    Proposed for the 11th edition of the World Health Organization's International Classification of Diseases (ICD-11) is a dimensional trait model for the classification of personality disorder (Tyrer, Reed, & Crawford, 2015). The ICD-11 proposal consists of 5 broad domains: negative affective, detachment, dissocial, disinhibition, and anankastic (Mulder, Horwood, Tyrer, Carter, & Joyce, 2016). Several field trials have examined this proposal, yet none has included a direct measure of the trait model. The purpose of the current study was to develop and provide initial validation for the Personality Inventory for ICD-11 (PiCD), a self-report measure of this proposed 5-domain maladaptive trait model. Item selection and scale construction proceeded through 3 initial data collections assessing potential item performance. Two subsequent studies were conducted for scale validation. In Study 1, the PiCD was evaluated in a sample of 259 MTurk participants (who were or had been receiving mental health treatment) with respect to 2 measures of general personality structure: The Eysenck Personality Questionnaire-Revised and the 5-Dimensional Personality Test. In Study 2, the PiCD was evaluated in an additional sample of 285 participants with respect to 2 measures of maladaptive personality traits: The Personality Inventory for DSM-5 and the Computerized Adaptive Test for Personality Disorders. Study 3 provides an item-level exploratory structural equation model with the combined samples from Studies 1 and 2. The results are discussed with respect to the validity of the measure and the potential benefits for future research in having a direct, self-report measure of the ICD-11 trait proposal. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  17. The Tragedy of the Implementation of ICD-10-CM as ICD-10: Is the Cart Before the Horse or Is There a Tragic Paradox of Misinformation and Ignorance?

    Science.gov (United States)

    Manchikanti, Laxmaiah; Kaye, Alan D; Singh, Vijay; Boswell, Mark V

    2015-01-01

    The forced implementation of ICD-10-CM (International Classification of Diseases, Tenth Revision, Clinical Modification) codes that are specific to the United States, scheduled for implementation October 1, 2015, which is vastly different from ICD-10 (International Classification of Diseases, Tenth Revision), implemented worldwide, which has 14,400 codes, compared to ICD-10-CM with 144,000 codes to be implemented in the United States is a major concern to practicing U.S. physicians and a bonanza for health IT and hospital industry. This implementation is based on a liberal interpretation of the Health Insurance Portability and Accountability Act (HIPAA), which requires an update to ICD-9-CM (International Classification of Diseases, Ninth Revision, Clinical Modification) and says nothing about ICD-10 or beyond. On June 29, 2015, the Supreme Court ruled that the Environmental Protection Agency unreasonably interpreted the Clean Air Act when it decided to set limits on the emissions of toxic pollutants from power plants, without first considering the costs on the industry. Thus, to do so is applicable to the medical industry with the Centers for Medicare and Medicaid Services (CMS) unreasonably interpreting HIPAA and imposing existent extensive regulations without considering the cost. In the United States, ICD-10-CM with a 10-fold increase in the number of codes has resulted in a system which has become so complicated that it no longer compares with any other country. Moreover, most WHO members use the ICD-10 system (not ICD-10-CM) only to record mortality in 138 countries or morbidity in 99 countries. Currently, only 10 countries employ ICD-10 (not ICD-10-CM) in the reimbursement process, 6 of which have a single payer health care system. Development of ICD-10-CM is managed by 4 non-physician groups, known as cooperating parties. They include the Centers for Disease Control and Prevention (CDC), CMS, the American Hospital Association (AHA), and the American Health

  18. Greater Prevalence of Proposed ICD-11 Alcohol and Cannabis Dependence Compared to ICD-10, DSM-IV, and DSM-5 in Treated Adolescents.

    Science.gov (United States)

    Chung, Tammy; Cornelius, Jack; Clark, Duncan; Martin, Christopher

    2017-09-01

    Proposed International Classification of Diseases, 11th edition (ICD-11), criteria for substance use disorder (SUD) radically simplify the algorithm used to diagnose substance dependence. Major differences in case identification across DSM and ICD impact determinations of treatment need and conceptualizations of substance dependence. This study compared the draft algorithm for ICD-11 SUD against DSM-IV, DSM-5, and ICD-10, for alcohol and cannabis. Adolescents (n = 339, ages 14 to 18) admitted to intensive outpatient addictions treatment completed, as part of a research study, a Structured Clinical Interview for DSM SUDs adapted for use with adolescents and which has been used to assess DSM and ICD SUD diagnoses. Analyses examined prevalence across classification systems, diagnostic concordance, and sources of diagnostic disagreement. Prevalence of any past-year proposed ICD-11 alcohol or cannabis use disorder was significantly lower compared to DSM-IV and DSM-5 (ps DSM-5, and ICD-10 (ps DSM-5 SUD diagnoses showed only moderate concordance. For both alcohol and cannabis, youth typically met criteria for an ICD-11 dependence diagnosis by reporting tolerance and much time spent using or recovering from the substance, rather than symptoms indicating impaired control over use. The proposed ICD-11 dependence algorithm appears to "overdiagnose" dependence on alcohol and cannabis relative to DSM-IV and ICD-10 dependence, and DSM-5 moderate/severe use disorder, generating potential "false-positive" cases of dependence. Among youth who met criteria for proposed ICD-11 dependence, few reported impaired control over substance use, highlighting ongoing issues in the conceptualization and diagnosis of SUD. Copyright © 2017 by the Research Society on Alcoholism.

  19. An On-Time Power-Aware Scheduling Scheme for Medical Sensor SoC-Based WBAN Systems

    OpenAIRE

    Hwang, Tae-Ho; Kim, Dong-Sun; Kim, Jung-Guk

    2012-01-01

    The focus of many leading technologies in the field of medical sensor systems is on low power consumption and robust data transmission. For example, the implantable cardioverter-defibrillator (ICD), which is used to maintain the heart in a healthy state, requires a reliable wireless communication scheme with an extremely low duty-cycle, high bit rate, and energy-efficient media access protocols. Because such devices must be sustained for over 5 years without access to battery replacement, the...

  20. Bystander defibrillation for out-of-hospital cardiac arrest in Public vs Residential Locations

    DEFF Research Database (Denmark)

    Hansen, Steen Møller; Hansen, Carolina Malta; Folke, Fredrik

    2017-01-01

    Importance: Bystander-delivered defibrillation (hereinafter referred to as bystander defibrillation) of patients with out-of-hospital cardiac arrests (OHCAs) remains limited despite the widespread dissemination of automated external defibrillators (AEDs). Objective: To examine calendar changes...... in bystander defibrillation and subsequent survival according to a public or a residential location of the cardiac arrest after nationwide initiatives in Denmark to facilitate bystander-mediated resuscitative efforts, including bystander defibrillation. Design, Setting, and Participants: This nationwide study......, 2016. Exposures: Nationwide initiatives to facilitate bystander resuscitative efforts, including bystander defibrillation, consisted of resuscitation training of Danish citizens, dissemination of on-site AEDs, foundation of an AED registry linked to emergency medical dispatch centers, and dispatcher...

  1. Factors associated with delayed defibrillation in cardiopulmonary resuscitation: A prospective simulation study.

    Directory of Open Access Journals (Sweden)

    Christoph Castan

    Full Text Available Early defibrillation is an important factor of survival in cardiac arrest. However, novice resuscitators often struggle with cardiac arrest patients. We investigated factors leading to delayed defibrillation performed by final-year medical students within a simulated bystander cardiac arrest situation.Final-year medical students received a refresher lecture and basic life support training before being confronted with a simulated cardiac arrest situation in a simulation ambulance. The scenario was analyzed for factors leading to delayed defibrillation. We compared the time intervals the participants needed for various measures with a benchmark set by experienced resuscitators. After training, the participants were interviewed regarding challenges and thoughts during the scenario.The median time needed for defibrillation was 158 s (n = 49, interquartile range: 107-270 s, more than six-fold of the benchmark time. The major part of total defibrillation time (49%; median, n = 49 was between onset of ventricular fibrillation and beginning to prepare the defibrillator, more specifically the time between end of preparation of the defibrillator and actual delivery of the shock, with a mean proportion of 26% (n = 49, SD = 17% of the overall time needed for defibrillation (maximum 67%. Self-reported reasons for this delay included uncertainty about the next step to take, as reported by 73% of the participants. A total of 35% were unsure about which algorithm to follow. Diagnosing the patient was subjectively difficult for 35% of the participants. Overall, 53% of the participants felt generally confused.Our study shows that novice resuscitators rarely achieve guideline-recommended defibrillation times. The most relative delays were observed when participants had to choose what to do next or which algorithm to follow, and thus i.e. performed extensive airway management before a life-saving defibrillation. Our data provides a first insight in the process of

  2. Live defibrillation in simulation-based medical education--a survey of simulation center practices and attitudes.

    Science.gov (United States)

    Turban, Joseph W; Peters, Deborah P; Berg, Benjamin W

    2010-02-01

    Resuscitation from cardiac arrhythmia, requiring cardioversion/defibrillation is a common simulation training scenario. Use of live defibrillation enhances simulation fidelity but is not without risk. This survey was conducted to describe the prevalence of live defibrillation use during training scenarios in healthcare simulation centers, and when used, if safety training was required before using live defibrillation. A convenience sample of attendees at the 7th annual International Meeting on Simulation in Healthcare (January 2007) was surveyed using a closed-ended 23-item survey instrument. Survey domains included responder and simulation center demographics, simulation center defibrillation safety policies, and attitudes toward defibrillation practices in simulation training environments. Fifty-seven individuals representing 39 simulation centers returned surveys, 29 of which were in the United States. Live defibrillation was used in 35 of the 39 centers (90%). A defibrillation safety training policy was in effect at 14 of 39 centers (36%). Formal training before using live defibrillation was considered necessary by 48 of 55 responders (87%). Forty-eight of 54 responders (89%) strongly agreed or agreed with the statement, "I feel using live defibrillation plays an important role in simulation-based education." Although most responders consider use of live defibrillation important and believe formal defibrillator safety training should be conducted before use, only about one third of the centers had a training policy in effect. It remains to be determined whether safety training before the use of live defibrillation during simulation-based education increases user safety.

  3. The Effects of Normothermic and Hypothermic Cardiopulmonary Bypass Upon Defibrillation Energy Requirements and Transmyocardial Impedance

    National Research Council Canada - National Science Library

    Martin, David

    1993-01-01

    .... To evaluate these questions we studied the effect of controlled hypothermia upon defibrillation energy requirements and transcardiac impedance in a canine model of cardiopulmonary bypass in which 26...

  4. Heart rate variability density analysis (Dyx) for identification of appropriate implantable cardioverter defibrillator recipients among elderly patients with acute myocardial infarction and left ventricular systolic dysfunction

    DEFF Research Database (Denmark)

    Jørgensen, Rikke Mørch; Levitan, Jacob; Halevi, Zohar

    2015-01-01

    AIMS: Dyx is a new heart rate variability (HRV) density analysis specifically designed to identify patients at high risk for malignant ventricular arrhythmias. The aim of this study was to test if Dyx can improve risk stratification for malignant ventricular tachyarrhythmias and to test if the pr......AIMS: Dyx is a new heart rate variability (HRV) density analysis specifically designed to identify patients at high risk for malignant ventricular arrhythmias. The aim of this study was to test if Dyx can improve risk stratification for malignant ventricular tachyarrhythmias and to test...

  5. Prophylactic catheter ablation of ventricular tachycardia before cardioverter-defibrillator implantation in patients with non-ischemic cardiomyopathy: Clinical outcomes after a single endocardial ablation

    Directory of Open Access Journals (Sweden)

    Atsushi Suzuki, MD

    2015-06-01

    Conclusion: Single endocardial PCA can decrease ES occurrence in NICM patients. However, high rates of VT recurrence and low success rates are issues to be resolved; therefore, the efficacy of single endocardial PCA is currently limited.

  6. The CopenHeartSF trial—comprehensive sexual rehabilitation programme for male patients with implantable cardioverter defibrillator or ischaemic heart disease and impaired sexual function

    DEFF Research Database (Denmark)

    Johansen, Pernille Palm; Zwisler, Ann-Dorthe; Svendsen, Jesper Hastrup

    2013-01-01

    Sexuality is an important part of people's physical and mental health. Patients with heart disease often suffer from sexual dysfunction. Sexual dysfunction has a negative impact on quality of life and well-being in persons with heart disease, and sexual dysfunction is associated with anxiety...... and depression. Treatment and care possibilities seem to be lacking. Studies indicate that non-pharmacological interventions such as exercise training and psychoeducation possess the potential of reducing sexual dysfunction in patients with heart disease. The CopenHeartSF trial will investigate the effect...

  7. Frequency of "Pocket" Hematoma in Patients Receiving Vitamin K Antagonist and Antiplatelet Therapy at the Time of Pacemaker or Cardioverter Defibrillator Implantation (from the POCKET Study).

    Science.gov (United States)

    Malagù, Michele; Trevisan, Filippo; Scalone, Antonella; Marcantoni, Lina; Sammarco, Giuseppe; Bertini, Matteo

    2017-04-01

    In patients undergoing cardiac device implantation, anticoagulant and antiplatelet therapy are associated with an increased risk of pocket hematoma. In case of vitamin K antagonist therapy, a strategy of continued warfarin with no heparin bridge showed a reduction of pocket hematoma. Evidence regarding antiplatelet therapy management is limited. This is a single-center observational study which reflects our systematic approach to the problem. In 2012, we proposed an improved management protocol for anticoagulant and antiplatelet therapy (no-bridge protocol) based on individual thromboembolic risk stratification, noninterruption of oral anticoagulation, no bridge with heparin and elastic adherence compression bandage. The primary end point was the incidence of clinically significant pocket hematoma in the first 30 days after implantation. A total of 1,035 patients were enrolled, of whom 522 received the standard management and 513 the new protocol. The primary end point occurred in 34 patients of the standard management group and 8 patients of the no-bridge protocol group (6.5% vs 1.6%, p hematoma (relative risk [RR] 3.48, 95% confidence interval [CI] 1.55 to 7.83 and RR 2.43, 95% CI 1.25 to 4.76, respectively), whereas the no-bridge protocol was associated with a reduction of pocket hematoma (RR 0.33, 95% CI 0.14 to 0.76). New anticoagulant and antiplatelet therapy management protocol was associated with a reduced incidence of clinically significant pocket hematomas, thromboembolic events, pocket infections, and lead dislodgements. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Anatomy of the ICDS series: A bibliometric analysis

    International Nuclear Information System (INIS)

    Cardona, Manuel; Marx, Werner

    2007-01-01

    In this article, the proceedings of the International Conferences on Defects in Semiconductors (ICDS) have been analyzed by bibliometric methods. The papers of these conferences have been published as articles in regular journals or special proceedings journals and in books with diverse publishers. The conference name/title changed several times. Many of the proceedings did not appear in the so-called 'source journals' covered by the Thomson/ISI citation databases, in particular by the Science Citation Index (SCI). But the number of citations within these source journals can be determined using the Cited Reference Search mode under the Web of Science (WoS) and the SCI offered by the host STN International. The search functions of both systems were needed to select the papers published as different document types and to cover the full time span of the series. The most cited ICDS papers were identified, and the overall numbers of citations as well as the time-dependent impact of these papers, of single conferences, and of the complete series, was established. The complete of citing papers was analyzed with respect to the countries of the citing authors, the citing journals, and the ISI subject categories

  9. The anti-tumor efficacy of nanoparticulate form of ICD-85 versus free form

    Directory of Open Access Journals (Sweden)

    Zare Mirakabadi, A.

    2015-04-01

    Full Text Available Biodegradable polymeric nanoparticles (NPs have been intensively studied as a possible way to enhance anti-tumor efficacy while reducing side effects. ICD-85, derived from the venom of two separate species of venomous animals, has been shown to exhibit anti-cancer activity. In this report polymer based sodium alginate nanoparticles of ICD-85 was used to enhance its therapeutic effects and reduce its side effects. The inhibitory effect was evaluated by MTT assay. The necrotic effect was assessed using LDH assay. The induction of apoptosis was analyzed by caspase-8 colorimetric assay kit. Cytotoxicity assay in HeLa cells demonstrated enhanced efficacy of ICD-85 loaded NPs compared to the free ICD-85. The IC50 values obtained in HeLa cells after 48 h, for free ICD-85 and ICD-85 loaded NPs were 26±2.9μg ml-1 and 18±2.5μg ml-1, respectively. While it was observed that free ICD-85 exhibits mild cytotoxicity towards normal MRC-5 cells (IC50>60μg ml-1, ICD-85 loaded NPs was found to have higher efficacy in anti-proliferative activity on HeLa cells in vitro without any significant cytotoxic effect on normal MRC-5 cells. The apoptosis-induction mechanism by both form of ICD-85 on HeLa cells was found to be through activation of caspase-8 with approximately 2 fold greater of ICD-85 loaded NPs as compared to free ICD-85. Our work reveals that although ICD-85 in free form is relatively selective to inhibit the growth of cancer cells via apoptosis as compared to normal cells, but nanoparticulate form increases its selectivity towards cancer cells.

  10. Estimation of current density distribution under electrodes for external defibrillation

    Directory of Open Access Journals (Sweden)

    Papazov Sava P

    2002-12-01

    Full Text Available Abstract Background Transthoracic defibrillation is the most common life-saving technique for the restoration of the heart rhythm of cardiac arrest victims. The procedure requires adequate application of large electrodes on the patient chest, to ensure low-resistance electrical contact. The current density distribution under the electrodes is non-uniform, leading to muscle contraction and pain, or risks of burning. The recent introduction of automatic external defibrillators and even wearable defibrillators, presents new demanding requirements for the structure of electrodes. Method and Results Using the pseudo-elliptic differential equation of Laplace type with appropriate boundary conditions and applying finite element method modeling, electrodes of various shapes and structure were studied. The non-uniformity of the current density distribution was shown to be moderately improved by adding a low resistivity layer between the metal and tissue and by a ring around the electrode perimeter. The inclusion of openings in long-term wearable electrodes additionally disturbs the current density profile. However, a number of small-size perforations may result in acceptable current density distribution. Conclusion The current density distribution non-uniformity of circular electrodes is about 30% less than that of square-shaped electrodes. The use of an interface layer of intermediate resistivity, comparable to that of the underlying tissues, and a high-resistivity perimeter ring, can further improve the distribution. The inclusion of skin aeration openings disturbs the current paths, but an appropriate selection of number and size provides a reasonable compromise.

  11. An MRI-Conditional External Cardiac Defibrillator for Resuscitation Within the MRI Scanner Bore

    Science.gov (United States)

    Schmidt, Ehud J.; Watkins, Ronald D.; Zviman, Menekhem M.; Guttman, Michael A.; Wang, Wei; Halperin, Henry A.

    2016-01-01

    Background Subjects undergoing cardiac arrest within an MRI scanner are currently removed from the bore and then from the MRI suite, prior to delivery of CPR and defibrillation, potentially increasing risk of mortality. This precludes many higher-risk (acute-ischemic, acute-stroke) patients from undergoing MRI imaging and MRI-guided intervention. An MRI-conditional cardiac defibrillator should enable scanning with defibrillation pads attached and the generator ON, enabling application of defibrillation within the MRI seconds after a cardiac event. An MRI-conditional external defibrillator may improve patient acceptance for MRI procedures. Methods and Results A commercial external defibrillator was rendered 1.5 Tesla MRI-conditional by addition of novel Radio-Frequency (RF) filters between the generator and commercial disposable surface-pads. The RF filters reduced emission into the MRI scanner, and prevented cable/surface-pad heating during imaging, while preserving all the defibrillator’s monitoring and delivery functions. Human volunteers were imaged using high Specific-Absorption-Rate sequences to validate MRI image quality (IQ) and lack of heating. Swine were electrically fibrillated (N=4) and thereafter defibrillated both outside and inside the MRI bore. MRI IQ was reduced by 0.8 or 1.6 dB, with the generator in monitoring mode and operating on battery or AC power, respectively. Commercial surface-pads did not create artifacts deeper than 6mm below the skin surface. RF heating was within FDA guidelines. Defibrillation was completely successful inside and outside the MRI bore. Conclusions A prototype MRI-conditional defibrillation system successfully defibrillated in the MRI without degrading image quality, or increasing the time needed for defibrillation. It can increase patient acceptance for MRI procedures. PMID:27729363

  12. Law Enforcement Agency Defibrillation (LEA-D): proceedings of the National Center for Early Defibrillation Police AED Issues Forum.

    Science.gov (United States)

    Mosesso, Vincent N; Newman, Mary M; Ornato, Joseph P; Paris, Paul M; Andersen, Leon; Brinsfield, Kathryn; Dunnavant, Gregory R; Frederick, Jay; Groh, William J; Johnston, Steven; Lerner, E Brooke; Murphy, George P; Myerburg, Robert J; Rosenberg, Donald G; Savino, Mitchell; Sayre, Michael R; Sciammarella, Joseph; Schoen, Valerie; Vargo, Philip; van Alem, Anouk; White, Roger D

    2002-01-01

    Why does LEA-D intervention seem to work in some systems but not others? Panelists agreed that some factors that delay rapid access to treatment, such as long travel distances in rural areas, may represent insurmountable barriers. Other factors, however, may be addressed more readily. These include: absence of a medical response culture, discomfort with the role of medical intervention, insecurity with the use of medical devices, a lack of proactive medical direction, infrequent refresher training, and dependence on EMS intervention. Panelists agreed that successful LEA-D programs possess ten key attributes (Table 6). In the end, the goal remains "early" defibrillation, not "police" defibrillation. It does not matter whether the rescuer wears a blue uniform--or any uniform, for that matter--so long as the defibrillator reaches the victim quickly. If LEA personnel routinely arrive at medical emergencies after other emergency responders or after 8 minutes have elapsed from the time of collapse, an LEA-D program will be unlikely to provide added value. Similarly, if police frequently arrive first, but the department is unwilling or unable to cultivate the attributes of successful LEA-D programs, efforts to improve survival may not be realized. In most communities, however, LEA-D programs have tremendous lifesaving potential and are well worth the investment of time and resources. Law enforcement agencies considering adoption of AED programs should review the frequency with which police arrive first at medical emergencies and LEA response intervals to determine whether AED programs might help improve survival in their communities. It is time for law enforcement agency defibrillation to become the rule, not the exception.

  13. Estimation of the Alpha Factor Parameters Using the ICDE Database

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Dae Il; Hwang, M. J.; Han, S. H

    2007-04-15

    Detailed common cause failure (CCF) analysis generally need for the data for CCF events of other nuclear power plants because the CCF events rarely occur. KAERI has been participated at the international common cause failure data exchange (ICDE) project to get the data for the CCF events. The operation office of the ICDE project sent the CCF event data for EDG to the KAERI at December 2006. As a pilot study, we performed the detailed CCF analysis of EDGs for Yonggwang Units 3 and 4 and Ulchin Units 3 and 4 using the ICDE database. There are two onsite EDGs for each NPP. When an offsite power and the two onsite EDGs are not available, one alternate AC (AAC) diesel generator (hereafter AAC) is provided. Two onsite EDGs and the AAC are manufactured by the same company, but they are designed differently. We estimated the Alpha Factor and the CCF probability for the cases where three EDGs were assumed to be identically designed, and for those were assumed to be not identically designed. For the cases where three EDGs were assumed to be identically designed, double CCF probabilities of Yonggwang Units 3/4 and Ulchin Units 3/4 for 'fails to start' were estimated as 2.20E-4 and 2.10E-4, respectively. Triple CCF probabilities of those were estimated as 2.39E-4 and 2.42E-4, respectively. As each NPP has no experience for 'fails to run', Yonggwang Units 3/4 and Ulchin Units 3/4 have the same CCF probability. The estimated double and triple CCF probabilities for 'fails to run' are 4.21E-4 and 4.61E-4, respectively. Quantification results show that the system unavailability for the cases where the three EDGs are identical is higher than that where the three EDGs are different. The estimated system unavailability of the former case was increased by 3.4% comparing with that of the latter. As a future study, a computerization work for the estimations of the CCF parameters will be performed.

  14. The role of conductivity discontinuities in design of cardiac defibrillation

    Science.gov (United States)

    Lim, Hyunkyung; Cun, Wenjing; Wang, Yue; Gray, Richard A.; Glimm, James

    2018-01-01

    Fibrillation is an erratic electrical state of the heart, of rapid twitching rather than organized contractions. Ventricular fibrillation is fatal if not treated promptly. The standard treatment, defibrillation, is a strong electrical shock to reinitialize the electrical dynamics and allow a normal heart beat. Both the normal and the fibrillatory electrical dynamics of the heart are organized into moving wave fronts of changing electrical signals, especially in the transmembrane voltage, which is the potential difference between the cardiac cellular interior and the intracellular region of the heart. In a normal heart beat, the wave front motion is from bottom to top and is accompanied by the release of Ca ions to induce contractions and pump the blood. In a fibrillatory state, these wave fronts are organized into rotating scroll waves, with a centerline known as a filament. Treatment requires altering the electrical state of the heart through an externally applied electrical shock, in a manner that precludes the existence of the filaments and scroll waves. Detailed mechanisms for the success of this treatment are partially understood, and involve local shock-induced changes in the transmembrane potential, known as virtual electrode alterations. These transmembrane alterations are located at boundaries of the cardiac tissue, including blood vessels and the heart chamber wall, where discontinuities in electrical conductivity occur. The primary focus of this paper is the defibrillation shock and the subsequent electrical phenomena it induces. Six partially overlapping causal factors for defibrillation success are identified from the literature. We present evidence in favor of five of these and against one of them. A major conclusion is that a dynamically growing wave front starting at the heart surface appears to play a primary role during defibrillation by critically reducing the volume available to sustain the dynamic motion of scroll waves; in contrast, virtual

  15. Bipolar and related disorders in DSM-5 and ICD-10.

    Science.gov (United States)

    Kaltenboeck, Alexander; Winkler, Dietmar; Kasper, Siegfried

    2016-08-01

    Bipolar disorders are a group of psychiatric disorders with profound negative impact on affected patients. Even if their symptomatology has long been recognized, diagnostic criteria have changed over time and diagnosis often remains difficult. The Fifth Edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5), issued in May 2013, comprises several changes regarding the diagnosis of bipolar disorders compared to the previous edition. Diagnostic categories and criteria for bipolar disorders show some concordance with the internationally also widely used Tenth Edition of the International Statistical Classification of Diseases and Related Health Problems (ICD-10). However, there are also major differences that are worth highlighting. The aim of the following text is to depict and discuss those.

  16. Expanding the definition of addiction: DSM-5 vs. ICD-11.

    Science.gov (United States)

    Grant, Jon E; Chamberlain, Samuel R

    2016-08-01

    While considerable efforts have been made to understand the neurobiological basis of substance addiction, the potentially "addictive" qualities of repetitive behaviors, and whether such behaviors constitute "behavioral addictions," is relatively neglected. It has been suggested that some conditions, such as gambling disorder, compulsive stealing, compulsive buying, compulsive sexual behavior, and problem Internet use, have phenomenological and neurobiological parallels with substance use disorders. This review considers how the issue of "behavioral addictions" has been handled by latest revisions of the Diagnostic and Statistical Manual of Mental Disorders (DSM) and the International Classification of Diseases (ICD), leading to somewhat divergent approaches. We also consider key areas for future research in order to address optimal diagnostic classification and treatments for such repetitive, debilitating behaviors.

  17. Effect of Cardiac Rehabilitation in Patients with ICD

    DEFF Research Database (Denmark)

    Christensen, Anne Vinggaard; Zwisler, Ann-Dorthe; Svendsen, Jesper Hastrup

    2015-01-01

    (rehabilitation: 47.7 points [SD 10.1] vs 54.8 points [7.1] and usual care: 48.1 points [SD 10.9] vs 51.9 points [SD 9.6], P = 0.05). CONCLUSIONS: After ICD implantation, significant gender differences were found in physical health, mental health, and QoL. Effects of rehabilitation were found among men only...... in physical component scale, mental component scale, social functioning, physical functioning, bodily pain, vitality, mental health, and QoL with men having higher scores. Among men only, significant differences were found in VO2 (rehabilitation: 20.9 mL/min/kg [standard deviation (SD) 8.1] vs 23.4 m...... and gender predicted effect of rehabilitation on the mental component scale....

  18. Parental alienation, DSM-5, and ICD-11: response to critics.

    Science.gov (United States)

    Bernet, William; Baker, Amy J L

    2013-01-01

    There has been considerable interest among forensic practitioners in the proposals that parental alienation be included in the next editions of the Diagnostic and Statistical Manual of Mental Diseases (DSM) and The International Classification of Diseases (ICD). However, there has also been a great deal of misunderstanding about the proposals, and misinformation has been expressed in professional meetings, on websites, and in journal articles. In this article we address four common misunderstandings regarding parental alienation: that there is a lack of research to support it as a diagnosis; that adopting parental alienation as a diagnosis will lead to serious adverse consequences; that the advocates of parental alienation are driven by self-serving or malevolent motives; and that Richard Gardner should be criticized for self-publishing his description of parental alienation syndrome.

  19. On the road to DSM-V and ICD-11.

    Science.gov (United States)

    Kupfer, David J; Regier, Darrel A; Kuhl, Emily A

    2008-11-01

    Development of the fifth edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-V) has been ongoing since 1994, though official release will not occur for another 4 years. Potential revisions are being derived from multiple sources, including building on perceived limitations of DSM-IV; broad-based literature reviews; secondary and primary data analyses; and discussions between global members of the mental health community. The current focus on aligning DSM with the International Classification of Diseases-11 (ICD-11) speaks to the importance of creating a unified text that embraces cross-cutting issues of diagnostics, such as developmental, age-related, and cultural phenomena. International discourse is vital to this process and has been fostered by a National Institutes of Health-sponsored conference series on diagnosis-specific topics. From this series, the DSM-V Task Force developed the following set of revision principals to guide the efforts of the DSM-V Work Groups: grounding recommendations in empirical evidence; maintaining continuity with previous editions of DSM; removing a priori limitations on the amount of changes DSM-V may incur; and maintaining DSM's status as a living document. With work group formation complete, members are currently carrying out the research and revision recommendations proposed during the conference series. Ongoing activities include adding specialized advisors to each work group; completing literature reviews and planning data analyses; and forming study groups to discuss integration of cross-cutting issues (e.g., developmental lifespan factors; formation of diagnostic spectra). The road to DSM-V and ICD-11 has been challenging, but members continue to work diligently in their goal of constructing the most harmonious, scientifically sound, and clinically relevant DSM to date.

  20. Defibrillation probability and impedance change between shocks during resuscitation from out-of-hospital cardiac arrest

    NARCIS (Netherlands)

    Walker, Robert G.; Koster, Rudolph W.; Sun, Charles; Moffat, George; Barger, Joseph; Dodson, Pamela P.; Chapman, Fred W.

    2009-01-01

    Objective: Technical data now gathered by automated external defibrillators (AEDs) allows closer evaluation of the behavior of defibrillation shocks administered during out-of-hospital cardiac arrest. We analyzed technical data from a large case series to evaluate the change in transthoracic

  1. Design, development and first validation of a transcoding system from ICD-9-CM to ICD-10 in the IT.DRG Italian project.

    Science.gov (United States)

    Della Mea, Vincenzo; Vuattolo, Omar; Frattura, Lucilla; Munari, Flavia; Verdini, Eleonora; Zanier, Loris; Arcangeli, Laura; Carle, Flavia

    2015-01-01

    In Italy, ICD-9-CM is currently used for coding health conditions at hospital discharge, but ICD-10 is being introduced thanks to the IT-DRG Project. In this project, one needed component is a set of transcoding rules and associated tools for easing coders work in the transition. The present paper illustrates design and development of those transcoding rules, and their preliminary testing on a subset of Italian hospital discharge data.

  2. Systematic review of validated case definitions for diabetes in ICD-9-coded and ICD-10-coded data in adult populations.

    Science.gov (United States)

    Khokhar, Bushra; Jette, Nathalie; Metcalfe, Amy; Cunningham, Ceara Tess; Quan, Hude; Kaplan, Gilaad G; Butalia, Sonia; Rabi, Doreen

    2016-08-05

    With steady increases in 'big data' and data analytics over the past two decades, administrative health databases have become more accessible and are now used regularly for diabetes surveillance. The objective of this study is to systematically review validated International Classification of Diseases (ICD)-based case definitions for diabetes in the adult population. Electronic databases, MEDLINE and Embase, were searched for validation studies where an administrative case definition (using ICD codes) for diabetes in adults was validated against a reference and statistical measures of the performance reported. The search yielded 2895 abstracts, and of the 193 potentially relevant studies, 16 met criteria. Diabetes definition for adults varied by data source, including physician claims (sensitivity ranged from 26.9% to 97%, specificity ranged from 94.3% to 99.4%, positive predictive value (PPV) ranged from 71.4% to 96.2%, negative predictive value (NPV) ranged from 95% to 99.6% and κ ranged from 0.8 to 0.9), hospital discharge data (sensitivity ranged from 59.1% to 92.6%, specificity ranged from 95.5% to 99%, PPV ranged from 62.5% to 96%, NPV ranged from 90.8% to 99% and κ ranged from 0.6 to 0.9) and a combination of both (sensitivity ranged from 57% to 95.6%, specificity ranged from 88% to 98.5%, PPV ranged from 54% to 80%, NPV ranged from 98% to 99.6% and κ ranged from 0.7 to 0.8). Overall, administrative health databases are useful for undertaking diabetes surveillance, but an awareness of the variation in performance being affected by case definition is essential. The performance characteristics of these case definitions depend on the variations in the definition of primary diagnosis in ICD-coded discharge data and/or the methodology adopted by the healthcare facility to extract information from patient records. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  3. 77 FR 32975 - AHRQ Workgroups on ICD-10-CM/PCS Conversion of Quality Indicators (QIs)

    Science.gov (United States)

    2012-06-04

    ... on ICD-10-CM/PCS Conversion of Quality Indicators (QIs) AGENCY: Agency for Healthcare Research and... workgroups, to be convened by AHRQ's contractor, on ICD-10-CM/PCS conversion of the AHRQ Quality Indicators..., please visit the AHRQ Web site at http://www.QUALITYindicators.AHRQ.gov . Specifically, each Workgroup on...

  4. A proposal for a standard communication protocol for pacemaker/ICD programmers

    NARCIS (Netherlands)

    Dijk, WA; Hooijschuur, CAM; van der Velde, W; Dassen, WRM

    2005-01-01

    The information generated by pacemakers and ICD's to support the cardiologist and technician for installing the optimal settings for the patient is increasing rapidly. In this paper a proposal is described for electronic data exchange between the pacemaker/ICD programmers and electronic information

  5. Minding the body: Situating gender identity diagnoses in the ICD-11

    NARCIS (Netherlands)

    Drescher, J.; Cohen-Kettenis, P.T.; Winter, S.

    2012-01-01

    The World Health Organization (WHO) is in the process of revising the International Statistical Classification of Diseases and Related Health Problems (ICD) and ICD-11 has an anticipated publication date of 2015. The Working Group on the Classification of Sexual Disorders and Sexual Health (WGSDSH)

  6. Results from the Veterans Health Administration ICD-10-CM/PCS Coding Pilot Study.

    Science.gov (United States)

    Weems, Shelley; Heller, Pamela; Fenton, Susan H

    2015-01-01

    The Veterans Health Administration (VHA) of the US Department of Veterans Affairs has been preparing for the October 1, 2015, conversion to the International Classification of Diseases, Tenth Revision, Clinical Modification and Procedural Coding System (ICD-10-CM/PCS) for more than four years. The VHA's Office of Informatics and Analytics ICD-10 Program Management Office established an ICD-10 Learning Lab to explore expected operational challenges. This study was conducted to determine the effects of the classification system conversion on coding productivity. ICD codes are integral to VHA business processes and are used for purposes such as clinical studies, performance measurement, workload capture, cost determination, Veterans Equitable Resource Allocation (VERA) determination, morbidity and mortality classification, indexing of hospital records by disease and operations, data storage and retrieval, research purposes, and reimbursement. The data collection for this study occurred in multiple VHA sites across several months using standardized methods. It is commonly accepted that coding productivity will decrease with the implementation of ICD-10-CM/PCS. The findings of this study suggest that the decrease will be more significant for inpatient coding productivity (64.5 percent productivity decrease) than for ambulatory care coding productivity (6.7 percent productivity decrease). This study reveals the following important points regarding ICD-10-CM/PCS coding productivity: 1. Ambulatory care ICD-10-CM coding productivity is not expected to decrease as significantly as inpatient ICD-10-CM/PCS coding productivity. 2. Coder training and type of record (inpatient versus outpatient) affect coding productivity. 3. Inpatient coding productivity is decreased when a procedure requiring ICD-10-PCS coding is present. It is highly recommended that organizations perform their own analyses to determine the effects of ICD-10-CM/PCS implementation on coding productivity.

  7. Validation of ICD-9 Codes for Stable Miscarriage in the Emergency Department.

    Science.gov (United States)

    Quinley, Kelly E; Falck, Ailsa; Kallan, Michael J; Datner, Elizabeth M; Carr, Brendan G; Schreiber, Courtney A

    2015-07-01

    International Classification of Disease, Ninth Revision (ICD-9) diagnosis codes have not been validated for identifying cases of missed abortion where a pregnancy is no longer viable but the cervical os remains closed. Our goal was to assess whether ICD-9 code "632" for missed abortion has high sensitivity and positive predictive value (PPV) in identifying patients in the emergency department (ED) with cases of stable early pregnancy failure (EPF). We studied females ages 13-50 years presenting to the ED of an urban academic medical center. We approached our analysis from two perspectives, evaluating both the sensitivity and PPV of ICD-9 code "632" in identifying patients with stable EPF. All patients with chief complaints "pregnant and bleeding" or "pregnant and cramping" over a 12-month period were identified. We randomly reviewed two months of patient visits and calculated the sensitivity of ICD-9 code "632" for true cases of stable miscarriage. To establish the PPV of ICD-9 code "632" for capturing missed abortions, we identified patients whose visits from the same time period were assigned ICD-9 code "632," and identified those with actual cases of stable EPF. We reviewed 310 patient records (17.6% of 1,762 sampled). Thirteen of 31 patient records assigned ICD-9 code for missed abortion correctly identified cases of stable EPF (sensitivity=41.9%), and 140 of the 142 patients without EPF were not assigned the ICD-9 code "632"(specificity=98.6%). Of the 52 eligible patients identified by ICD-9 code "632," 39 cases met the criteria for stable EPF (PPV=75.0%). ICD-9 code "632" has low sensitivity for identifying stable EPF, but its high specificity and moderately high PPV are valuable for studying cases of stable EPF in epidemiologic studies using administrative data.

  8. Eccentric apical hypertrophic cardiomyopathy unmasked by multimodality imaging: an uncommon but missed cause of out of hospital cardiac arrest

    Science.gov (United States)

    Towe, Eric; Sharma, Saurabh; Geske, Jeffrey; Ackerman, Michael J

    2015-01-01

    A woman in her late 50s experienced a witnessed, sudden out of hospital cardiac arrest. Initial workup included coronary angiography, transthoracic echocardiogram and a CT scan of the chest to rule out pulmonary embolus. She was subsequently discharged home without an implantable cardioverter defibrillator (ICD) or a life vest. On follow-up at another facility, an ICD was placed and a Holter monitor showed no ventricular ectopy. Further transthoracic echocardiographic images were obtained, which were suggestive of apical hypertrophic cardiomyopathy. A limited transthoracic echocardiogram with contrast was performed, which did not elucidate the hypertrophy. However, eccentric left ventricular apical wall hypertrophy was visualised by a coronary CT scan. PMID:26153133

  9. Erroneous Magnet Positioning Leads to Failure of Inhibition of Inappropriate Shock during Fast Conducting Atrial Fibrillation Episodes.

    Science.gov (United States)

    Römers, Hans; VAN Dijk, Vincent; Balt, Jippe

    2017-06-01

    We present the case of a 75-year-old patient with a single-chamber St. Jude Medical internal cardioverter defibrillator (ICD; St. Jude Medical, St. Paul, MN, USA) for primary prevention, who was admitted with 39 inappropriate ICD shocks because of atrial fibrillation with rapid ventricular frequention, despite magnet placement. Review of the device manual and literature revealed that apart from different responses to magnet placement programmed for the various manufacturers, the type of magnet and the positioning can be of specific interest. In the case presented, the donut-shaped magnet should have been placed off-center instead of directly over the device. © 2017 Wiley Periodicals, Inc.

  10. Bystander Defibrillation for Out-of-Hospital Cardiac Arrest in Public vs Residential Locations.

    Science.gov (United States)

    Hansen, Steen Møller; Hansen, Carolina Malta; Folke, Fredrik; Rajan, Shahzleen; Kragholm, Kristian; Ejlskov, Linda; Gislason, Gunnar; Køber, Lars; Gerds, Thomas A; Hjortshøj, Søren; Lippert, Freddy; Torp-Pedersen, Christian; Wissenberg, Mads

    2017-05-01

    Bystander-delivered defibrillation (hereinafter referred to as bystander defibrillation) of patients with out-of-hospital cardiac arrests (OHCAs) remains limited despite the widespread dissemination of automated external defibrillators (AEDs). To examine calendar changes in bystander defibrillation and subsequent survival according to a public or a residential location of the cardiac arrest after nationwide initiatives in Denmark to facilitate bystander-mediated resuscitative efforts, including bystander defibrillation. This nationwide study identified 18 688 patients in Denmark with first-time OHCA from June 1, 2001, to December 31, 2012, using the Danish Cardiac Arrest Registry. Patients had a presumed cardiac cause of arrest that was not witnessed by emergency medical services personnel. Data were analyzed from April 1, 2015, to December 10, 2016. Nationwide initiatives to facilitate bystander resuscitative efforts, including bystander defibrillation, consisted of resuscitation training of Danish citizens, dissemination of on-site AEDs, foundation of an AED registry linked to emergency medical dispatch centers, and dispatcher-assisted guidance of bystander resuscitation efforts. The proportion of patients who received bystander defibrillation according to the location of the cardiac arrest and their subsequent 30-day survival. Of the 18 688 patients with OHCAs (67.8% men and 32.2% women; median [interquartile range] age, 72 [62-80] years), 4783 (25.6%) had a cardiac arrest in a public location and 13 905 (74.4%) in a residential location. The number of registered AEDs increased from 141 in 2007 to 7800 in 2012. The distribution of AED location was consistently skewed in favor of public locations. Bystander defibrillation increased in public locations from 3 of 245 (1.2%; 95% CI, 0.4%-3.5%) in 2001 to 78 of 510 (15.3%; 95% CI, 12.4%-18.7%) in 2012 (P bystander defibrillation increased in public locations from 8.3% (95% CI, 1.5%-35.4%) in 2001/2002 to 57

  11. Mental and behavioural disorders in the ICD-11: concepts, methodologies, and current status.

    Science.gov (United States)

    Gaebel, Wolfgang; Zielasek, Jürgen; Reed, Geoffrey M

    2017-04-30

    This review provides an overview of the concepts, methods and current status of the development of the Eleventh Revision of the Mental and Behavioural Disorders chapter of the International Classification of Diseases and Related Health Problems (ICD-11) by the World Health Organization (WHO). Given the global use of the current version (ICD-10) for a wide range of applications in clinical practice and health statistics, a major aim of the development process for ICD-11 has been to increase the utility of the classification system. Expert working groups with responsibility for specific disorder groupings first suggested a set of revised diagnostic guidelines. Then surveys were performed to obtain suggestions for revisions from practicing health professionals. A completely revised structure for the classification of mental and behavioural disorders was developed and major revisions were suggested, for example, for schizophrenia and other primary psychotic disorders, substance use disorders, affective disorders and personality disorders. A new category of "gaming disorder" has been proposed and conditions related to sexual health and gender identity will be classified separately from mental disorders. An ICD-11 beta draft is freely available on the internet and public comments are invited. Field studies of the revised diagnostic guidelines are in process to obtain additional information about necessary improvements. A tabulated crosswalk from previous ICD-10 to then ICD-11 criteria will be necessary to ascertain the continuity of diagnoses for epidemiological and other statistical purposes. The final version of ICD-11 is currently scheduled for release by the World Health Assembly in 2018.

  12. The Utility and Challenges of Using ICD Codes in Child Maltreatment Research: A Review of Existing Literature

    Science.gov (United States)

    Scott, Debbie; Tonmyr, Lil; Fraser, Jenny; Walker, Sue; McKenzie, Kirsten

    2009-01-01

    Objective: The objectives of this article are to explore the extent to which the International Statistical Classification of Diseases and Related Health Problems (ICD) has been used in child abuse research, to describe how the ICD system has been applied, and to assess factors affecting the reliability of ICD coded data in child abuse research.…

  13. Intracellular fragment of NLRR3 (NLRR3-ICD) stimulates ATRA-dependent neuroblastoma differentiation

    International Nuclear Information System (INIS)

    Akter, Jesmin; Takatori, Atsushi; Islam, Md. Sazzadul; Nakazawa, Atsuko; Ozaki, Toshinori; Nagase, Hiroki; Nakagawara, Akira

    2014-01-01

    Highlights: • NLRR3 is a membrane protein highly expressed in favorable neuroblastoma. • NLRR3-ICD was produced through proteolytic processing by secretases. • NLRR3-ICD was induced to be translocated into cell nucleus following ATRA exposure. • NLRR3-ICD plays a pivotal role in ATRA-mediated neuroblastoma differentiation. - Abstract: We have previously identified neuronal leucine-rich repeat protein-3 (NLRR3) gene which is preferentially expressed in favorable human neuroblastomas as compared with unfavorable ones. In this study, we have found for the first time that NLRR3 is proteolytically processed by secretases and its intracellular domain (NLRR3-ICD) is then released to translocate into cell nucleus during ATRA-mediated neuroblastoma differentiation. According to our present observations, NLRR3-ICD was induced to accumulate in cell nucleus of neuroblastoma SH-SY5Y cells following ATRA treatment. Since the proteolytic cleavage of NLRR3 was blocked by α- or γ-secretase inhibitor, it is likely that NLRR3-ICD is produced through the secretase-mediated processing of NLRR3. Intriguingly, forced expression of NLRR3-ICD in neuroblastoma SK-N-BE cells significantly suppressed their proliferation as examined by a live-cell imaging system and colony formation assay. Similar results were also obtained in neuroblastoma TGW cells. Furthermore, overexpression of NLRR3-ICD stimulated ATRA-dependent neurite elongation in SK-N-BE cells. Together, our present results strongly suggest that NLRR3-ICD produced by the secretase-mediated proteolytic processing of NLRR3 plays a crucial role in ATRA-mediated neuronal differentiation, and provide a clue to develop a novel therapeutic strategy against aggressive neuroblastomas

  14. Intracellular fragment of NLRR3 (NLRR3-ICD) stimulates ATRA-dependent neuroblastoma differentiation

    Energy Technology Data Exchange (ETDEWEB)

    Akter, Jesmin [Laboratory of Innovative Cancer Therapeutics, Chiba Cancer Center Research Institute, Chiba 260-8717 (Japan); Takatori, Atsushi, E-mail: atakatori@chiba-cc.jp [Laboratory of Cancer Genetics, Chiba Cancer Center Research Institute, Chiba 260-8717 (Japan); Islam, Md. Sazzadul [Laboratory of Innovative Cancer Therapeutics, Chiba Cancer Center Research Institute, Chiba 260-8717 (Japan); Nakazawa, Atsuko [Department of Pathology, National Center for Child Health and Development, Tokyo (Japan); Ozaki, Toshinori, E-mail: tozaki@chiba-cc.jp [Laboratory of DNA Damage Signaling, Chiba Cancer Center Research Institute, Chiba 260-8717 (Japan); Nagase, Hiroki [Laboratory of Cancer Genetics, Chiba Cancer Center Research Institute, Chiba 260-8717 (Japan); Nakagawara, Akira [Saga Medical Centre, 840-8571 (Japan)

    2014-10-10

    Highlights: • NLRR3 is a membrane protein highly expressed in favorable neuroblastoma. • NLRR3-ICD was produced through proteolytic processing by secretases. • NLRR3-ICD was induced to be translocated into cell nucleus following ATRA exposure. • NLRR3-ICD plays a pivotal role in ATRA-mediated neuroblastoma differentiation. - Abstract: We have previously identified neuronal leucine-rich repeat protein-3 (NLRR3) gene which is preferentially expressed in favorable human neuroblastomas as compared with unfavorable ones. In this study, we have found for the first time that NLRR3 is proteolytically processed by secretases and its intracellular domain (NLRR3-ICD) is then released to translocate into cell nucleus during ATRA-mediated neuroblastoma differentiation. According to our present observations, NLRR3-ICD was induced to accumulate in cell nucleus of neuroblastoma SH-SY5Y cells following ATRA treatment. Since the proteolytic cleavage of NLRR3 was blocked by α- or γ-secretase inhibitor, it is likely that NLRR3-ICD is produced through the secretase-mediated processing of NLRR3. Intriguingly, forced expression of NLRR3-ICD in neuroblastoma SK-N-BE cells significantly suppressed their proliferation as examined by a live-cell imaging system and colony formation assay. Similar results were also obtained in neuroblastoma TGW cells. Furthermore, overexpression of NLRR3-ICD stimulated ATRA-dependent neurite elongation in SK-N-BE cells. Together, our present results strongly suggest that NLRR3-ICD produced by the secretase-mediated proteolytic processing of NLRR3 plays a crucial role in ATRA-mediated neuronal differentiation, and provide a clue to develop a novel therapeutic strategy against aggressive neuroblastomas.

  15. Automated external defibrillators in the Australian fitness industry.

    Science.gov (United States)

    Norton, Kevin I; Norton, Lynda H

    2008-04-01

    Sudden cardiac arrest (SCA) occurs in many thousands of Australians each year. Scientific evidence shows an increased survival rate for individuals who receive electrical defibrillation in the first few minutes after SCA. In the last decade automated (rhythm-detecting) external defibrillators (AEDs) have become available that are portable and affordable. Although still relatively rare, there is still the potential that SCA may occur when a person undertakes physical activity. Consequently, health/fitness centres are increasingly recognised as higher risk sites that may benefit from placement of AEDs. There are no laws in Australia requiring health/fitness centres to install AEDs. However, several international and professional organisations have "strongly encouraged" larger centres to install AEDs. Guidelines and algorithms are presented to help estimate the risk of SCA in fitness centres. Fitness centre placement is particularly important if the clientele is older or has a 'high-risk' profile, for example, clients with cardiovascular, respiratory or metabolic disease. International negligence case law and duty of care principles suggests the standard of care required in health/fitness centres may be increasing. Therefore, it may be prudent to install AEDs in larger centres and those in which higher risk groups are physically active.

  16. Evidence of distinct profiles of Posttraumatic Stress Disorder (PTSD) and Complex Posttraumatic Stress Disorder (CPTSD) based on the new ICD-11 Trauma Questionnaire (ICD-TQ).

    Science.gov (United States)

    Karatzias, Thanos; Shevlin, Mark; Fyvie, Claire; Hyland, Philip; Efthymiadou, Erifili; Wilson, Danielle; Roberts, Neil; Bisson, Jonathan I; Brewin, Chris R; Cloitre, Marylene

    2017-01-01

    The WHO International Classification of Diseases, 11th version (ICD-11), has proposed two related diagnoses following exposure to traumatic events; Posttraumatic Stress Disorder (PTSD) and Complex PTSD (CPTSD). We set out to explore whether the newly developed ICD-11 Trauma Questionnaire (ICD-TQ) can distinguish between classes of individuals according to the PTSD and CPTSD symptom profiles as per ICD-11 proposals based on latent class analysis. We also hypothesized that the CPTSD class would report more frequent and a greater number of different types of childhood trauma as well as higher levels of functional impairment. Methods Participants in this study were a sample of individuals who were referred for psychological therapy to a National Health Service (NHS) trauma centre in Scotland (N=193). Participants completed the ICD-TQ as well as measures of life events and functioning. Overall, results indicate that using the newly developed ICD-TQ, two subgroups of treatment-seeking individuals could be empirically distinguished based on different patterns of symptom endorsement; a small group high in PTSD symptoms only and a larger group high in CPTSD symptoms. In addition, CPTSD was more strongly associated with more frequent and a greater accumulation of different types of childhood traumatic experiences and poorer functional impairment. Sample predominantly consisted of people who had experienced childhood psychological trauma or been multiply traumatised in childhood and adulthood. CPTSD is highly prevalent in treatment seeking populations who have been multiply traumatised in childhood and adulthood and appropriate interventions should now be developed to aid recovery from this debilitating condition. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Utilization of YouTube as a Tool to Assess Patient Perception Regarding Implanted Cardiac Devices.

    Science.gov (United States)

    Hayes, Kevin; Mainali, Prajeena; Deshmukh, Abhishek; Pant, Sadip; Badheka, Apurva O; Paydak, Hakan

    2014-07-01

    The outreach of YouTube may have a dramatic role in the widespread dissemination of knowledge on implantable cardioverter devices (ICD). This study was designed to review and analyze the information available on YouTube pertaining to implantable cardiac devices such as implantable cardioverter defibrillators (ICDs) and pacemakers. YouTube was queried for the terms "ICD", "Implantable Cardioverter Defibrillator", and "Pacemaker". The videos were reviewed and categorized as according to content; number of views and "likes" or "dislikes" was recorded by two separate observers. Of the 55 videos reviewed, 18 of the videos were categorized as patient education, 12 were advertisements, 8 were intraoperative videos documenting the device implantation procedures, 7 of the videos were produced to document personal patient experiences, and 4 were categorized as documentation of a public event. 3 were intended to educate health care workers. The remaining 3 were intended to raise public awareness about sudden cardiac death. The videos portraying intraoperative procedures generated the most "likes" or "dislikes" per view. While YouTube provides a logical platform for delivery of health information, the information on this platform is not regulated. Initiative by reputed authorities and posting accurate information in such platform can be a great aid in public education regarding device therapy.

  18. An evaluation of ICD-11 posttraumatic stress disorder criteria in two samples of adolescents and young adults exposed to mass shootings: factor analysis and comparisons to ICD-10 and DSM-IV.

    Science.gov (United States)

    Haravuori, Henna; Kiviruusu, Olli; Suomalainen, Laura; Marttunen, Mauri

    2016-05-12

    The proposed posttraumatic stress disorder (PTSD) criteria for the International Classification of Diseases (ICD) 11th revision are simpler than the criteria in ICD-10, DSM-IV or DSM-5. The aim of this study was to evaluate the ICD-11 PTSD factor structure in samples of young people, and to compare PTSD prevalence rates and diagnostic agreement between the different diagnostic systems. Possible differences in clinical characteristics of the PTSD cases identified by ICD-11, ICD-10 and DSM-IV are explored. Two samples of adolescents and young adults were followed after exposure to similar mass shooting incidents in their schools. Semi-structured diagnostic interviews were performed to assess psychiatric diagnoses and PTSD symptom scores (N = 228, mean age 17.6 years). PTSD symptom item scores were used to compose diagnoses according to the different classification systems. Confirmatory factor analyses indicated that the proposed ICD-11 PTSD symptoms represented two rather than three factors; re-experiencing and avoidance symptoms comprised one factor and hyperarousal symptoms the other factor. In the studied samples, the three-factor ICD-11 criteria identified 51 (22.4%) PTSD cases, the two-factor ICD-11 identified 56 (24.6%) cases and the DSM-IV identified 43 (18.9%) cases, while the number of cases identified by ICD-10 was larger, being 85 (37.3%) cases. Diagnostic agreement of the ICD-11 PTSD criteria with ICD-10 and DSM-IV was moderate, yet the diagnostic agreement turned to be good when an impairment criterion was imposed on ICD-10. Compared to ICD-11, ICD-10 identified cases with less severe trauma exposure and posttraumatic symptoms and DSM-IV identified cases with less severe trauma exposure. The findings suggest that the two-factor model of ICD-11 PTSD is preferable to the three-factor model. The proposed ICD-11 criteria are more restrictive compared to the ICD-10 criteria. There were some differences in the clinical characteristics of the PTSD cases

  19. Epidemiology, course and outcome of acute polymorphic psychotic disorder: implications for ICD-11

    DEFF Research Database (Denmark)

    Castagnini, Augusto; Foldager, Leslie

    2014-01-01

    Background: The proposed revision of the ICD-10 category of ‘acute and transient psychotic disorders' (ATPDs), subsuming polymorphic, schizophrenic or predominantly delusional syndromes, would restrict their classification to acute polymorphic psychotic disorder, reminiscent of the clinical...

  20. Effects of postshock atrial pacing on atrial defibrillation outcome in the isolated sheep heart

    NARCIS (Netherlands)

    Skanes, A. C.; Gray, R. A.; Zuur, C. L.; Jalife, J.

    1998-01-01

    BACKGROUND: Failed atrial defibrillation shocks are associated with organization of postshock activity and a substantial postshock electrical quiescence. We investigated the ability of a train of pacing stimuli to capture or locally entrain atrial myocardium during the quiescent period after

  1. Use of automated external defibrillators in a Brazilian airline. A 1-year experience

    Directory of Open Access Journals (Sweden)

    Alves Paulo Magalhães

    2001-01-01

    Full Text Available After the incorporation of automated external defibrilators by other airlines and the support of the Brazilian Society of cardiology, Varig Airlines Began the onboard defibrilation program with the initial purpose of equiping wide-body aircrafts frequently used in international flights and that airplanes use in the Rio - São Paulo route. With all fight attendants trained, the automated. External defibrilation devides were incorporated to 34 airplanes of a total pleet of 80 aircrats. The devices were intalled in the bagage compartments secured with velero straps and 2 pairs of electrods, one or which pre-conected to the device to minimize application time. Later, a portable monitor was addres to the ressocitation kit in the long flights. The expansion of the knowledge of the basic life support fundamentors and the correted implantation of the survival chain and of the automated external defibrilators will increase the extense of recovery of cardiorespiratory arrest victins in aircrafts.

  2. International common-cause failure data exchange. ICDE general coding guidelines - Technical note

    International Nuclear Information System (INIS)

    Johanson, Gunnar; Werner, Wolfgang; Concepcion Capote, Marina; Kreuser, Albert; Rasmuson, Dale; Jonsson, Esther; Pereira Pagan, Begona; Tirira, Jorge; Morris, Ian; Morales, Rosa; Oxberry, Anna; Kreuser, Albert

    2004-01-01

    Several Member countries of the Nuclear Energy Agency of the Organisation for Economic Co-operation and Development (OECD/NEA) have established the International Common-Cause Failure Data Exchange Project (ICDE Project) to encourage multilateral co-operation in the collection and analysis of data relating to Common-Cause Failure (CCF) events. The objectives of the ICDE Project are to: a) Collect and analyse CCF events over the long term so as to better understand such events, their causes, and their prevention; b) Generate qualitative insights into the root causes of CCF events which can then be used to derive approaches or mechanisms for their prevention or for mitigating their consequences; c) Establish a mechanism for the efficient feedback of experience gained in connection with CCF phenomena, including the development of defences against their occurrence, such as indicators for risk based inspections; and d) Record event attributes to facilitate quantification of CCF frequencies when so decided by the Project Working Group. The ICDE Project is envisaged to comprise all possible events of interest, including both complete and partial ICDE events. The ICDE Project will cover the key components of the main safety systems. Presently, the components listed below are included in the ICDE Project. Data have been collected for the six first components in the list: Centrifugal pumps, Diesel generators, Motor operated valves, Safety relief valves/power operated relief valves, Check valves, Batteries, Level measurement, Breakers, Control rod drive assemblies. Others will be added to this list later on. In this component coding guidelines, explanations on the ICDE General coding format are given. The guide reflects present experience with the data format and with the collected data. Further interpretations and clarifications will be added, should they become necessary. For each component analysed in the ICDE project, separate coding guidance is provided in the appendices

  3. Training and support to improve ICD coding quality: A controlled before-and-after impact evaluation

    Directory of Open Access Journals (Sweden)

    Robin Dyers

    2017-06-01

    Full Text Available Background. The proposed National Health Insurance policy for South Africa (SA requires hospitals to maintain high-quality International Statistical Classification of Diseases (ICD codes for patient records. While considerable strides had been made to improve ICD coding coverage by digitising the discharge process in the Western Cape Province, further intervention was required to improve data quality. The aim of this controlled before-and-after study was to evaluate the impact of a clinician training and support initiative to improve ICD coding quality. Objective. To compare ICD coding quality between two central hospitals in the Western Cape before and after the implementation of a training and support initiative for clinicians at one of the sites. Methods. The difference in differences in data quality between the intervention site and the control site was calculated. Multiple logistic regression was also used to determine the odds of data quality improvement after the intervention and to adjust for potential differences between the groups. Results. The intervention had a positive impact of 38.0% on ICD coding completeness over and above changes that occurred at the control site. Relative to the baseline, patient records at the intervention site had a 6.6 (95% confidence interval 3.5 - 16.2 adjusted odds ratio of having a complete set of ICD codes for an admission episode after the introduction of the training and support package. The findings on impact on ICD coding accuracy were not significant. Conclusion. There is sufficient pragmatic evidence that a training and support package will have a considerable positive impact on ICD coding completeness in the SA setting.

  4. International Common Cause Failure Data Exchange (ICDE). General Coding Guidelines - Updated Version, October 2011

    International Nuclear Information System (INIS)

    Johanson, Gunnar; Werner, Wolfgang; Capote, Marina Concepcion; Kreuser, Albert

    2012-01-01

    Several OECD/NEA member countries have established the International Common-Cause Failure Data Exchange Project ('ICDE Project') to encourage multilateral cooperation in the collection and analysis of data relating to Common-Cause Failure (CCF) events. The objectives of the ICDE Project are to: a) Collect and analyse CCF events over the long term so as to better understand such events, their causes, and their prevention. b) Generate qualitative insights into the root causes of CCF events which can then be used to derive approaches or mechanisms for their prevention or for mitigating their consequences. c) Establish a mechanism for the efficient feedback of experience gained in connection with CCF phenomena, including the development of defenses against their occurrence, such as indicators for risk based inspections. d) Record event attributes to facilitate quantification of CCF frequencies when so decided by the Project Working Group. The ICDE Project is envisaged to comprise all possible events of interest, including both complete and partial ICDE events. The ICDE Project will cover the key components of the main safety systems. Presently, the components listed below are included in the ICDE Project. Data have been collected for the six first components in the list: Centrifugal pumps, Diesel generators, Motor operated valves, Safety relief valves/power operated relief valves, Check valves, Batteries, Level measurement, Breakers, Control rod drive assemblies. Others will be added to this list later on. In this component coding guidelines, explanations on the ICDE general coding format are given. The guide reflects present experience with the data format and with the collected data. Further interpretations and clarifications will be added, should they become necessary. For each component analysed in the ICDE project, separate coding guidance is provided in the appendices ICDECG 01-06, specifying details relevant to the respective components

  5. Nuclear Ep-ICD expression is a predictor of poor prognosis in "low risk" prostate adenocarcinomas.

    Directory of Open Access Journals (Sweden)

    Jasmeet Assi

    Full Text Available Molecular markers for predicting prostate cancer (PCa that would have poor prognosis are urgently needed for a more personalized treatment for patients. Regulated intramembrane proteolysis of Epithelial cell adhesion molecule results in shedding of the extracellular domain (EpEx and release of its intracellular domain (Ep-ICD which triggers oncogenic signaling and might correlate to tumor aggressiveness. This study aimed to explore the potential of Ep-ICD and EpEx to identify PCa that have poor prognosis.Immunohistochemical analysis of Ep-ICD and EpEx was carried out in normal prostate tissues (n = 100, benign prostate hyperplasia (BPH, n = 83, and prostate cancer (n = 249 using domain specific antibodies. The expression of Ep-ICD and EpEx was correlated with clinico- pathological parameters and disease free survival (DFS.Reduced expression of nuclear Ep-ICD and membrane EpEx was observed in PCa in comparison with BPH and normal prostate tissues (p = 0.006, p < 0.001 respectively. For patients who had PCa with Gleason Score less than 7, preserved nuclear Ep-ICD emerged as the most significant marker in multivariate analysis for prolonged DFS, where these patients did not have recurrence during follow up of up to 12 years (p = 0.001.Reduced expression of nuclear Ep-ICD was associated with shorter disease free survival in patients with a Gleason Score less than 7 and may be useful in identifying patients likely to have aggressive tumors with poor prognosis. Furthermore, nuclear Ep-ICD can differentiate between normal and prostate cancer tissues for ambiguous cases.

  6. Training and support to improve ICD coding quality: A controlled before-and-after impact evaluation.

    Science.gov (United States)

    Dyers, Robin; Ward, Grant; Du Plooy, Shane; Fourie, Stephanus; Evans, Juliet; Mahomed, Hassan

    2017-05-24

    The proposed National Health Insurance policy for South Africa (SA) requires hospitals to maintain high-quality International Statistical Classification of Diseases (ICD) codes for patient records. While considerable strides had been made to improve ICD coding coverage by digitising the discharge process in the Western Cape Province, further intervention was required to improve data quality. The aim of this controlled before-and-after study was to evaluate the impact of a clinician training and support initiative to improve ICD coding quality. To compare ICD coding quality between two central hospitals in the Western Cape before and after the implementation of a training and support initiative for clinicians at one of the sites. The difference in differences in data quality between the intervention site and the control site was calculated. Multiple logistic regression was also used to determine the odds of data quality improvement after the intervention and to adjust for potential differences between the groups. The intervention had a positive impact of 38.0% on ICD coding completeness over and above changes that occurred at the control site. Relative to the baseline, patient records at the intervention site had a 6.6 (95% confidence interval 3.5 - 16.2) adjusted odds ratio of having a complete set of ICD codes for an admission episode after the introduction of the training and support package. The findings on impact on ICD coding accuracy were not significant. There is sufficient pragmatic evidence that a training and support package will have a considerable positive impact on ICD coding completeness in the SA setting.

  7. Collaboration between specialties for respiratory allergies in the International Classification of Diseases (ICD)-11.

    Science.gov (United States)

    Tanno, Luciana Kase; Calderon, Moises; Linzer, Jeffrey F; Chalmers, Robert J G; Demoly, Pascal

    2017-02-10

    The International Classification of Diseases (ICD) has been grouping the allergic and hypersensitivity disorders involving the respiratory tract under topographic distribution, regardless of the underlying mechanisms, triggers or concepts currently in use for allergic and hypersensitivity conditions. In order to strengthen awareness and deliberate the creation of the new "Allergic or hypersensitivity disorders involving the respiratory tract" section of the ICD-11, we here propose make the building process public. The new frame has been constructed to cover the gaps previously identified and was based on consensus academic reports and ICD-11 principles. Constant and bilateral discussion was kept with relevant groups representing specialties and resulted in proposals submission into the ICD-11 online platform. The "Allergic or hypersensitivity disorders involving the respiratory tract" section covers 64 entities distributed across five main categories. All the 79 proposals submitted resulted from an intensive collaboration of the Allergy working group, relevant Expert working groups and the WHO ICD governance. The establishment of the ICD-11 "Allergic or hypersensitivity disorders involving the respiratory tract" section will allow the dissemination of the updated concepts to be used in clinical practice by many different specialties and health professionals.

  8. Piloting a Collaborative Web-Based System for Testing ICD-11.

    Science.gov (United States)

    Donada, Marc; Kostanjsek, Nenad; Della Mea, Vincenzo; Celik, Can; Jakob, Robert

    2017-01-01

    The 11th revision of the International Classification of Diseases (ICD-11), for the first time in ICD history, deployed web-based collaboration of experts and ICT tools. To ensure that ICD-11 is working well, it needs to be systematically field tested in different settings, across the world. This will be done by means of a number of experiments. In order to support its implementation, a web-based system (ICDfit) has been designed and developed. The present paper illustrates the current prototype of the system and its technical testing. the system has been designed according to WHO requirements, and implemented using PHP and MySQL. Then, a preliminary technical test has been designed and run in January 2016, involving 8 users. They had to carry out double coding, that is, coding case summaries with both ICD-10 and ICD-11, and answering quick questions on the coding difficulty. the 8 users coded 632 cases each, spending an average of 163 seconds per case. While we found an issue in the mechanism used to record coding times, no further issues were found. the proposed system seems to be technically adequate for supporting future ICD-11 testing.

  9. Migration to the ICD-10 coding system: A primer for spine surgeons (Part 1).

    Science.gov (United States)

    Rahmathulla, Gazanfar; Deen, H Gordon; Dokken, Judith A; Pirris, Stephen M; Pichelmann, Mark A; Nottmeier, Eric W; Reimer, Ronald; Wharen, Robert E

    2014-01-01

    On 1 October 2015, a new federally mandated system goes into effect requiring the replacement of the International Classification of Disease-version 9-Clinical Modification (ICD-9-CM) with ICD-10-CM. These codes are required to be used for reimbursement and to substantiate medical necessity. ICD-10 is composite with as many as 141,000 codes, an increase of 712% when compared to ICD-9. Execution of the ICD-10 system will require significant changes in the clinical administrative and hospital-based practices. Through the transition, diminished productivity and practice revenue can be anticipated, the impacts of which the spine surgeon can minimizeby appropriate education and planning. The advantages of the new system include increased clarity and more accurate definitions reflecting patient condition, information relevant to ambulatory and managed care encounters, expanded injury codes, laterality, specificity, precise data for safety and compliance reporting, data mining for research, and finally, enabling pay-for-performance programs. The disadvantages include the cost per physician, training administrative staff, revenue loss during the learning curve, confusion, the need to upgrade hardware along with software, and overall expense to the healthcare system. With the deadline rapidly approaching, gaps in implementation result in delayed billing, delayed or diminished reimbursements, and absence of quality and outcomes data. It is thereby essential for spine surgeons to understand their role in transitioning to this new environment. Part I of this article discusses the background, coding changes, and costs as well as reviews the salient features of ICD-10 in spine surgery.

  10. Automated external defibrillators in National Collegiate Athletic Association Division I Athletics.

    Science.gov (United States)

    Coris, Eric E; Sahebzamani, Frances; Walz, Steve; Ramirez, Arnold M

    2004-01-01

    Sudden cardiac death is the leading cause of death in athletes. Evidence on current sudden cardiac death prevention through preparticipation history, physicals, and noninvasive cardiovascular diagnostics has demonstrated a low sensitivity for detection of athletes at high risk of sudden cardiac death. Data are lacking on automated external defibrillator programs specifically initiated to respond to rare dysrhythmia in younger, relatively low-risk populations. Surveys were mailed to the head athletic trainers of all National Collegiate Athletic Association Division I athletics programs listed in the National Athletic Trainers' Association directory. In all, 303 surveys were mailed; 186 departments (61%) responded. Seventy-two percent (133) of responding National Collegiate Athletic Association Division I athletics programs have access to automated external defibrillator units; 54% (101) own their units. Proven medical benefit (55%), concern for liability (51%), and affordability (29%) ranked highest in frequency of reasons for automated external defibrillator purchase. Unit cost (odds ratio = 1.01; 95% confidence interval, 1.01-1.0), donated units (odds ratio = 1.92; confidence interval, 3.66-1.01), institution size (odds ratio =.0001; confidence interval, 1.3 E-4 to 2.2E-05), and proven medical benefit of automated external defibrillators (odds ratio = 24; confidence interval, 72-8.1) were the most significant predictors of departmental defibrillator ownership. Emergency medical service response time and sudden cardiac death event history were not significantly predictive of departmental defibrillator ownership. The majority of automated external defibrillator interventions occurred on nonathletes. Many athletics medicine programs are obtaining automated external defibrillators without apparent criteria for determination of need. Usage and maintenance policies vary widely among departments with unit ownership or access. Programs need to approach the issue of unit

  11. A qualitative study to identify barriers to deployment and student training in the use of automated external defibrillators in schools

    DEFF Research Database (Denmark)

    Zinckernagel, Line; Hansen, Carolina Malta; Rod, Morten Hulvej

    2017-01-01

    such as delayed access have been reported. The purpose of this study was to identify barriers to the implementation of defibrillator training of students and deployment of defibrillators in schools. Methods: A qualitative study based on semi-structured individual interviews and focus groups with a total of 25......Background: Student training in use of automated external defibrillators and deployment of such defibrillators in schools is recommended to increase survival after out-of-hospital cardiac arrest. Low implementation rates have been observed, and even at schools with a defibrillator, challenges...... to their perception of student training but not for their considerations on the relevance of their placement at schools. Conclusions: It is crucial for implementation of automated external defibrillators in schools to inform staff about how they work and are operated and that students are an appropriate target group...

  12. A qualitative study to identify barriers to deployment and student training in the use of automated external defibrillators in schools

    DEFF Research Database (Denmark)

    Zinckernagel, Line; Hansen, Carolina Malta; Rod, Morten Hulvej

    2017-01-01

    to their perception of student training but not for their considerations on the relevance of their placement at schools. Conclusions: It is crucial for implementation of automated external defibrillators in schools to inform staff about how they work and are operated and that students are an appropriate target group...... for defibrillator training. Furthermore, it is important to provide schools with a basis for decision making about when to install defibrillators, and to ensure that school staff and students are informed about their placement.......Background: Student training in use of automated external defibrillators and deployment of such defibrillators in schools is recommended to increase survival after out-of-hospital cardiac arrest. Low implementation rates have been observed, and even at schools with a defibrillator, challenges...

  13. COPE-ICD: A randomised clinical trial studying the effects and meaning of a comprehensive rehabilitation programme for ICD recipients -design, intervention and population

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Svendsen, Jesper H; Zwisler, Ann-Dorthe

    2011-01-01

    Growing evidence exists that living with an ICD can lead to fear and avoidance behaviour including the avoidance of physical activity. It has been suggested that psychological stress can increase the risk of shock and predict death. Small studies have indicated a beneficial effect arising from ex...... exercise training and psychological intervention, therefore a large-scale rehabilitation programme was set up....

  14. Attitudes toward automated external defibrillator use in Japan.

    Science.gov (United States)

    Taniguchi, Takumi; Omi, Wataru; Inaba, Hideo

    2008-11-01

    The American Heart Association 2005 Guidelines recommend immediate defibrillation for ventricular fibrillation (VF) of short duration, such as witnessed sudden cardiac arrest. However, it is unclear if public-access automated external defibrillators (AEDs) would actually be used in Japan, because there have been few studies about public attitudes regarding AED use. Therefore, we examined Japanese attitudes toward AED use. Between February and March 2006, 3328 individuals, including high school students, teachers, emergency medical technicians (EMTs), medical nurses, and medical students, were asked about AED knowledge and their willingness to operate an AED. All EMTs, 86% of nurses, and 90% of medical students knew how to use AEDs, while only 15% of high school students and 44% of teachers had such knowledge. All EMTs, 78% of nurses, and 94% of medical students reported they would 'definitely' use the AED, but only 12% of high school students and 35% of teachers gave this reply. The reasons for unwillingness to operate AEDs among both laypeople and health care providers were poor of awareness of what AED is and/or how to use an AED. However, 83% of students and 81% of teachers with AED knowledge reported they would 'definitely' use the AED. Many non-medical people in Japan would be unwilling to operate an AED, because they do not know what AED is and/or how to use an AED. However, many would be willing to operate AEDs if they had better understanding of AEDs. Thus, it is necessary to improve public knowledge of AEDs and AED use.

  15. Optimizing a Drone Network to Deliver Automated External Defibrillators.

    Science.gov (United States)

    Boutilier, Justin J; Brooks, Steven C; Janmohamed, Alyf; Byers, Adam; Buick, Jason E; Zhan, Cathy; Schoellig, Angela P; Cheskes, Sheldon; Morrison, Laurie J; Chan, Timothy C Y

    2017-06-20

    Public access defibrillation programs can improve survival after out-of-hospital cardiac arrest, but automated external defibrillators (AEDs) are rarely available for bystander use at the scene. Drones are an emerging technology that can deliver an AED to the scene of an out-of-hospital cardiac arrest for bystander use. We hypothesize that a drone network designed with the aid of a mathematical model combining both optimization and queuing can reduce the time to AED arrival. We applied our model to 53 702 out-of-hospital cardiac arrests that occurred in the 8 regions of the Toronto Regional RescuNET between January 1, 2006, and December 31, 2014. Our primary analysis quantified the drone network size required to deliver an AED 1, 2, or 3 minutes faster than historical median 911 response times for each region independently. A secondary analysis quantified the reduction in drone resources required if RescuNET was treated as a large coordinated region. The region-specific analysis determined that 81 bases and 100 drones would be required to deliver an AED ahead of median 911 response times by 3 minutes. In the most urban region, the 90th percentile of the AED arrival time was reduced by 6 minutes and 43 seconds relative to historical 911 response times in the region. In the most rural region, the 90th percentile was reduced by 10 minutes and 34 seconds. A single coordinated drone network across all regions required 39.5% fewer bases and 30.0% fewer drones to achieve similar AED delivery times. An optimized drone network designed with the aid of a novel mathematical model can substantially reduce the AED delivery time to an out-of-hospital cardiac arrest event. © 2017 American Heart Association, Inc.

  16. A Study on Performance and Safety Tests of Defibrillator Equipment

    Directory of Open Access Journals (Sweden)

    Tavakoli Golpaygani A.

    2017-12-01

    Full Text Available Introduction: Nowadays, more than 10,000 different types of medical devices can be found in hospitals. This way, medical electrical equipment is being employed in a wide variety of fields in medical sciences with different physiological effects and measurements. Hospitals and medical centers must ensure that their critical medical devices are safe, accurate, reliable and operational at the required level of performance. Defibrillators are critical resuscitation devices. The use of reliable defibirillators has led to more effective treatments and improved patient safety through better control and management of complications during Cardiopulmonary Resuscitation (CPR. Materials and Methods: The metrological reliability of twenty frequent use, manual defibrillators in use ten hospitals (4 private and 6 public in one of the provinces of Iran according to international and national standards was evaluated. Results: Quantitative analysis of control and instrument accuracy showed the amount of the obtained results in many units are critical which had less value over the standard limitations especially in devices with poor battery. For the accuracy of delivered energy analysis, only twelve units delivered acceptable output values and the precision in the output energy measurements especialy in weak battry condition, after activation of discharge alarm, were low. Conclusion: Obtained results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially for high risk instruments. It is also necessary to provide training courses on the fundumentals of operation and performane parameters for medical staff in the field of meterology in medicine and how one can get good accuracy results especially in high risk medical devices.

  17. A Study on Performance and Safety Tests of Defibrillator Equipment.

    Science.gov (United States)

    Tavakoli Golpaygani, A; Movahedi, M M; Reza, M

    2017-12-01

    Nowadays, more than 10,000 different types of medical devices can be found in hospitals. This way, medical electrical equipment is being employed in a wide variety of fields in medical sciences with different physiological effects and measurements. Hospitals and medical centers must ensure that their critical medical devices are safe, accurate, reliable and operational at the required level of performance. Defibrillators are critical resuscitation devices. The use of reliable defibirillators has led to more effective treatments and improved patient safety through better control and management of complications during Cardiopulmonary Resuscitation (CPR). The metrological reliability of twenty frequent use, manual defibrillators in use ten hospitals (4 private and 6 public) in one of the provinces of Iran according to international and national standards was evaluated. Quantitative analysis of control and instrument accuracy showed the amount of the obtained results in many units are critical which had less value over the standard limitations especially in devices with poor battery. For the accuracy of delivered energy analysis, only twelve units delivered acceptable output values and the precision in the output energy measurements especialy in weak battry condition, after activation of discharge alarm, were low. Obtained results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially for high risk instruments. It is also necessary to provide training courses on the fundumentals of operation and performane parameters for medical staff in the field of meterology in medicine and how one can get good accuracy results especially in high risk medical devices.

  18. Hands-On Defibrillation Skills of Pediatric Acute Care Providers During a Simulated Ventricular Fibrillation Cardiac Arrest Scenario.

    Science.gov (United States)

    Bhalala, Utpal S; Balakumar, Niveditha; Zamora, Maria; Appachi, Elumalai

    2018-01-01

    Introduction: Timely defibrillation in ventricular fibrillation cardiac arrest (VFCA) is associated with good outcome. While defibrillation skills of pediatric providers have been reported to be poor, the factors related to poor hands-on defibrillation skills of pediatric providers are largely unknown. The aim of our study was to evaluate delay in individual steps of the defibrillation and human and non-human factors associated with poor hands-on defibrillation skills among pediatric acute care providers during a simulated VFCA scenario. Methods: We conducted a prospective observational study of video evaluation of hands-on defibrillation skills of pediatric providers in a simulated VFCA in our children's hospital. Each provider was asked to use pads followed by paddles to provide 2 J/kg shock to an infant mannequin in VFCA. The hands-on skills were evaluated for struggle with any step of defibrillation, defined a priori as >10 s delay with particular step. The data was analyzed using chi-square test with significant p -value 10 s delay) with each of connecting the pads/paddles to the device, using pads/paddles on the mannequin and using buttons on the machine was 34 (50%), 26 (38%), and 31 (46%), respectively. Conclusions: The defibrillation skills of providers in a tertiary care children's hospital are poor. Both human and machine-related factors are associated with delay in defibrillation. Prior use of the study defibrillator is associated with a significantly shorter time-to-first shock as compared to prior use of any other defibrillator or no prior use of any defibrillator.

  19. A Magnetic Resonance Imaging-Conditional External Cardiac Defibrillator for Resuscitation Within the Magnetic Resonance Imaging Scanner Bore.

    Science.gov (United States)

    Schmidt, Ehud J; Watkins, Ronald D; Zviman, Menekhem M; Guttman, Michael A; Wang, Wei; Halperin, Henry A

    2016-10-01

    Subjects undergoing cardiac arrest within a magnetic resonance imaging (MRI) scanner are currently removed from the bore and then from the MRI suite, before the delivery of cardiopulmonary resuscitation and defibrillation, potentially increasing the risk of mortality. This precludes many higher-risk (acute ischemic and acute stroke) patients from undergoing MRI and MRI-guided intervention. An MRI-conditional cardiac defibrillator should enable scanning with defibrillation pads attached and the generator ON, enabling application of defibrillation within the seconds of MRI after a cardiac event. An MRI-conditional external defibrillator may improve patient acceptance for MRI procedures. A commercial external defibrillator was rendered 1.5 Tesla MRI-conditional by the addition of novel radiofrequency filters between the generator and commercial disposable surface pads. The radiofrequency filters reduced emission into the MRI scanner and prevented cable/surface pad heating during imaging, while preserving all the defibrillator monitoring and delivery functions. Human volunteers were imaged using high specific absorption rate sequences to validate MRI image quality and lack of heating. Swine were electrically fibrillated (n=4) and thereafter defibrillated both outside and inside the MRI bore. MRI image quality was reduced by 0.8 or 1.6 dB, with the generator in monitoring mode and operating on battery or AC power, respectively. Commercial surface pads did not create artifacts deeper than 6 mm below the skin surface. Radiofrequency heating was within US Food and Drug Administration guidelines. Defibrillation was completely successful inside and outside the MRI bore. A prototype MRI-conditional defibrillation system successfully defibrillated in the MRI without degrading the image quality or increasing the time needed for defibrillation. It can increase patient acceptance for MRI procedures. © 2016 American Heart Association, Inc.

  20. EuroEco (European Health Economic Trial on Home Monitoring in ICD Patients): a provider perspective in five European countries on costs and net financial impact of follow-up with or without remote monitoring.

    Science.gov (United States)

    Heidbuchel, Hein; Hindricks, Gerd; Broadhurst, Paul; Van Erven, Lieselot; Fernandez-Lozano, Ignacio; Rivero-Ayerza, Maximo; Malinowski, Klaus; Marek, Andrea; Romero Garrido, Rafael F; Löscher, Steffen; Beeton, Ian; Garcia, Enrique; Cross, Stephen; Vijgen, Johan; Koivisto, Ulla-Maija; Peinado, Rafael; Smala, Antje; Annemans, Lieven

    2015-01-14

    Remote follow-up (FU) of implantable cardiac defibrillators (ICDs) allows for fewer in-office visits in combination with earlier detection of relevant findings. Its implementation requires investment and reorganization of care. Providers (physicians or hospitals) are unsure about the financial impact. The primary end-point of this randomized prospective multicentre health economic trial was the total FU-related cost for providers, comparing Home Monitoring facilitated FU (HM ON) to regular in-office FU (HM OFF) during the first 2 years after ICD implantation. Also the net financial impact on providers (taking national reimbursement into account) and costs from a healthcare payer perspective were evaluated. A total of 312 patients with VVI- or DDD-ICD implants from 17 centres in six EU countries were randomised to HM ON or OFF, of which 303 were eligible for data analysis. For all contacts (in-office, calendar- or alert-triggered web-based review, discussions, calls) time-expenditure was tracked. Country-specific cost parameters were used to convert resource use into monetary values. Remote FU equipment itself was not included in the cost calculations. Given only two patients from Finland (one in each group) a monetary valuation analysis was not performed for Finland. Average age was 62.4 ± 13.1 years, 81% were male, 39% received a DDD system, and 51% had a prophylactic ICD. Resource use with HM ON was clearly different: less FU visits (3.79 ± 1.67 vs. 5.53 ± 2.32; P financial impact on providers [profit of €408 (327-489) vs. €400 (345-455); range for difference (€-104 to 88), NS], but there was heterogeneity among countries, with less profit for providers in the absence of specific remote FU reimbursement (Belgium, Spain, and the Netherlands) and maintained or increased profit in cases where such reimbursement exists (Germany and UK). Quality of life (SF-36) was not different. For all the patients as a whole, FU-related costs for providers are not

  1. Hartrevalidatie bij patiënten met een aangeboren hartafwijking, een implanteerbare defibrillator of chronisch hartfalen.

    NARCIS (Netherlands)

    Brügemann, J.; Postema, K.; van Gelder, I.C.; Oosterwijk, M.H.; van Veldhuisen, D.J.

    2004-01-01

    Cardiac rehabilitation is no longer just used to treat patients after the manifestation of a coronary artery disease such as a myocardial infarct, after a PTCA or after a coronary bypass operation. Patients with a congenital heart disease, patients who have received an implantable cardioverter

  2. Sikkerhed af magnetisk resonans-skanning hos patienter med pacemaker og implanterbar defibrillator

    DEFF Research Database (Denmark)

    Al-Sabagh, Kifah Hekmat; Christensen, Britta Ege; Thøgersen, Anna Margrethe

    2010-01-01

    The presence of a cardiac implantable device is ICD considered an absolute contraindication to magnetic resonance imaging (MRI). The purpose of this study was to evaluate the safety of performing MRI in patients with cardiac pacemakers and ICDs that had a compelling clinical need for MRI examinat......The presence of a cardiac implantable device is ICD considered an absolute contraindication to magnetic resonance imaging (MRI). The purpose of this study was to evaluate the safety of performing MRI in patients with cardiac pacemakers and ICDs that had a compelling clinical need for MRI...

  3. Primary ICD-therapy in patients with advanced heart failure: selection strategies and future trials.

    Science.gov (United States)

    Frankenstein, Lutz; Zugck, Christian; Nelles, Manfred; Schellberg, Dieter; Remppis, Andrew; Katus, Hugo

    2008-09-01

    For allocation of primary ICD-therapy, a possible lower limit of inclusion criteria--defining overly advanced heart failure--is less well investigated. Also, a multi-variable approach to stratification beyond ejection fraction (LVEF) appears warranted. We examined whether adding a selection limit of peak VO(2) ICD-therapy. All cause mortality was considered as end point. Median follow-up was 45 (18-86) months. ICD was not a significant predictor of outcome either for the entire population, or grouped according to aetiology of CHF. Still, 3-year mortality was 15% (ICD-patients) Vs. 28% (non-ICD-patients); P = 0.05; under combination medical therapy. Inversely, in ICD-patients medical combination therapy conveyed a significant survival benefit (P < 0.001). Consequently, the number-needed-to-treat was eight under combination therapy and the size estimate amounts to 300 patients for a prospective trial in this cohort. A cut-off of LVEF ICD-therapy. Our results indicate the need for a specific randomized trial in this cohort. The according mortality data and a size estimate are provided.

  4. Dominant Suppression of β1 Integrin by Ectopic CD98-ICD Inhibits Hepatocellular Carcinoma Progression

    Directory of Open Access Journals (Sweden)

    Bo Wu

    2016-11-01

    Full Text Available Hepatocellular carcinoma (HCC is currently the third most common cause of cancer-related death in the Asia-Pacific region. Our previous work showed that knockdown of CD98 significantly inhibits malignant HCC cell phenotypes in vitro and in vivo. The level of CD98 in the membrane is tightly regulated to mediate complex processes associated with cell–cell communication and intracellular signaling. In addition, the intracellular domain of CD98 (CD98-ICD seems to be of vital importance for recycling CD98 to the membrane after it is endocytosed. The intracellular and transmembrane domains of CD98 associate with β-integrins (primarily β1 but also β3, and this association is essential for CD98 mediation of integrin-like signaling and complements dominant suppression of β1-integrin. We speculated that isolated CD98-ICD would similarly suppress β1-integrin activation and inhibit the malignant behaviors of cancer cells. In particular, the exact role of CD98-ICD has not been studied independently in HCC. In this study, we found that ectopic expression of CD98-ICD inhibited the malignant phenotypes of HCC cells, and the mechanism possibly involves β1-integrin suppression. Moreover, the expression levels of CD98, β1-integrin-A (the activated form of β1-integrin and Ki-67 were significantly increased in HCC tissues relative to those of normal liver tissues. Therefore, our preliminary study indicates that ectopic CD98-ICD has an inhibitory role in the malignant development of HCC, and shows that CD98-ICD acts as a dominant negative mutant of CD98 that attenuates β1-integrin activation. CD98-ICD may emerge as a promising candidate for antitumor treatment.

  5. Updating Allergy and/or Hypersensitivity Diagnostic Procedures in the WHO ICD-11 Revision.

    Science.gov (United States)

    Tanno, Luciana Kase; Calderon, Moises A; Li, James; Casale, Thomas; Demoly, Pascal

    2016-01-01

    The classification of allergy and/or hypersensitivity conditions for the World Health Organization (WHO) International Classification of Diseases (ICD)-11 provides the appropriate corresponding codes for allergic diseases, assuming that the final diagnosis is correct. This classification should be linked to in vitro and in vivo diagnostic procedures. Considering the impact for our specialty, we decided to review the codification of these procedures into the ICD aiming to have a baseline and to suggest changes and/or submit new proposals. For that, we prepared a list of the relevant allergy and/or hypersensitivity diagnostic procedures that health care professionals are dealing with on a daily basis. This was based on the main current guidelines and selected all possible and relevant corresponding terms from the ICD-10 (2015 version) and the ICD-11 β phase foundation (June 2015 version). More than 90% of very specific and important diagnostic procedures currently used by the allergists' community on a daily basis are missing. We observed that some concepts usually used by the allergist community on a daily basis are not fully recognized by other specialties. The whole scheme and the correspondence in the ICD-10 (2015 version) and ICD-11 foundation (June 2015 version) provided us a big picture of the missing or imprecise terms and how they are scattered in the current ICD-11 framework, allowing us to submit new proposals to increase the visibility of the allergy and/or hypersensitivity conditions and diagnostic procedures. Copyright © 2016 American Academy of Allergy, Asthma & Immunology. All rights reserved.

  6. Screening and risk evaluation for sudden cardiac death in ischaemic and non-ischaemic cardiomyopathy

    DEFF Research Database (Denmark)

    Proclemer, Alessandro; Lewalter, Thorsten; Bongiorni, Maria Grazia

    2013-01-01

    The purpose of this EHRA survey was to examine the current clinical practice of screening and risk evaluation for sudden cardiac death in ischaemic and non-ischaemic cardiomyopathy with a focus on selection of candidates for implantable cardioverter-defibrillator (ICD) therapy, timing of ICD...... implantation, and use of non-invasive and invasive diagnostic tests across Europe. A systematic screening programme for sudden cardiac death existed in 19 out of 31 centres (61.3%). Implantation of ICDs according to the inclusion criteria of MADIT-II and SCD-HeFT trials was reported in 30 and 29% of centres......, respectively, followed by MADIT-CRT (18%), COMPANION (16%), and combined MADIT and MUSTT (7%) indications. In patients with severe renal impairment, ICD implantation for primary prevention of sudden death was always avoided in 8 centres (33.3%), was not used only if creatinine level was >2.5 mg/dL in 10...

  7. Internal defibrillation: pain perception of low energy shocks.

    Science.gov (United States)

    Steinhaus, David M; Cardinal, Debbie S; Mongeon, Luc; Musley, Shailesh Kumar; Foley, Laura; Corrigan, Susie

    2002-07-01

    Recently, device-based low energy cardoversion shocks have been used as therapy for AF. However, discomfort from internal low energy electrical shocks is poorly understood. The aim of this study was to evaluate pain perception with low energy internal discharges. Eighteen patients with ICD devices for malignant ventricular arrhythmias were recruited to receive shocks of 0.4 and 2 J in the nonsedated state. Discharges were delivered in a blinded, random order and questionnaires were used to determine discomfort levels and tolerability. Patients perceived discharges at these energies as relatively uncomfortable, averaging a score of 7.3 on a discomfort scale of 0-10, and could not distinguish 0.4-J shocks from 2-J shocks. Second shocks were perceived as more uncomfortable than initial discharges, regardless of the order in which the shocks were delivered. Despite the perceived discomfort, 83% of patients stated that they would tolerate discharges of this magnitude once per month, and 44% would tolerate weekly discharges. Patients perceive low energy discharges as painful and cannot distinguish between shocks of 0.4 and 2 J. The results suggest that ICD systems developed to treat atrial tachyarrhythmias should minimize the number of shocks delivered to terminate an atrial tachyarrhythmia episode. The majority of the patients tolerated low energy shocks provided the discharges are infrequent (once per month).

  8. Structure of DSM-5 and ICD-11 personality domains in Iranian community sample.

    Science.gov (United States)

    Lotfi, Mozhgan; Bach, Bo; Amini, Mahdi; Simonsen, Erik

    2018-02-02

    Personality disorders (PD) have been deemed the most problematic diagnostic grouping in terms of validity and utility, which particularly applies to non-Western societies. The current study evaluated the structural validity of PD trait domains in the Diagnostic and Statistical Manual of Mental Disorders-5 (DSM-5) Section III and the proposed International Classification of Diseases-11 (ICD-11) in the Iranian population. Community-dwelling adults (n = 285; 66% women) were administered the Personality Inventory for DSM-5, whereas the proposed ICD-11 trait domains were delineated using an algorithm for Personality Inventory for DSM-5 trait facets. The five-factor organization and higher-order hierarchical structure of both models were examined using exploratory structural equation modelling analyses. The five-factor exploratory structural equation modelling loadings overall resembled international findings on DSM-5 Section III traits (including Psychoticism), whereas the ICD-11 five-factor structure aligned with the proposed ICD-11 domain features (including Anankastia). Additionally, we identified a hierarchical structure from one to five factors for both models that conceptually aligned with established models of personality and psychopathology. This study provided initial support for the structural validity of DSM-5 and ICD-11 PD trait models in Iranian culture. Future research warrants replication in larger samples and clinical populations. Copyright © 2018 John Wiley & Sons, Ltd. Copyright © 2018 John Wiley & Sons, Ltd.

  9. DSM-IV, DSM-5, and ICD-11: Identifying children with posttraumatic stress disorder after disasters.

    Science.gov (United States)

    Danzi, BreAnne A; La Greca, Annette M

    2016-12-01

    Different criteria for diagnosing posttraumatic stress disorder (PTSD) have been recommended by the 5th edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5) and the proposed 11th edition of the International Classification of Diseases (ICD-11). Although children are vulnerable to PTSD following disasters, little is known about whether these revised criteria are appropriate for preadolescents, as diagnostic revisions have been based primarily on adult research. This study investigated rates of PTSD using DSM-IV, DSM-5, and ICD-11 diagnostic criteria, and their associations with symptom severity, impairment, and PTSD risk factors. Children (7-11 years) exposed to Hurricanes Ike (n = 327) or Charley (n = 383) completed measures 8-9 months postdisaster. Using diagnostic algorithms for DSM-IV, DSM-5, and ICD-11, rates of 'probable' PTSD were calculated. Across samples, rates of PTSD were similar. However, there was low agreement across the diagnostic systems, with about a third overlap in identified cases. Children identified only by ICD-11 had higher 'core' symptom severity but lower impairment than children identified only by DSM-IV or DSM-5. ICD-11 was associated with more established risk factors for PTSD than was DSM-5. Findings revealed differences in PTSD diagnosis across major diagnostic systems for preadolescent children, with no clear advantage to any one system. Further research on developmentally sensitive PTSD criteria for preadolescent children is needed. © 2016 Association for Child and Adolescent Mental Health.

  10. Harmonisation of ICD-11 and DSM-V: opportunities and challenges.

    Science.gov (United States)

    First, Michael B

    2009-11-01

    Differences in the ICD-10 and DSM-IV definitions for the same disorder impede international communication and research efforts. The forthcoming parallel development of DSM-V and ICD-11 offers an opportunity to harmonise the two classifications. This paper aims to facilitate the harmonisation process by identifying diagnostic differences between the two systems. DSM-IV-TR criteria sets and the ICD-10 Diagnostic Criteria for Research were compared and categorised into those with identical definitions, those with conceptually based differences and those in which differences are not conceptually based and appear to be unintentional. Of the 176 criteria sets in both systems, only one, transient tic disorder, is identical. Twenty-one per cent had conceptually based differences and 78% had non-conceptually based differences. Harmonisation of criteria sets, especially those with non-conceptually based differences, should be prioritised in the DSM-V and ICD-11 development process. Prior experience with the DSM-IV and ICD-10 harmonisation effort suggests that for the process to be successful steps should be taken as early as possible.

  11. Technical design report for the upgrade of the ICD for D-Zero Run II

    International Nuclear Information System (INIS)

    Sawyer, L.; De, K.; Draper, P.; Gallas, E.; Li, J.; Sosebee, M.; Stephens, R.W.; White, A.

    1998-01-01

    The Inter Cryostat Detector (ICD) used in Run I of the D0 Experiment will be inoperable in the central, high magnetic field planned for Run II. In Run I, the ICD enhanced the hermeticity and uniformity of the D0 calorimeter system, improving both missing transverse energy and jet energy resolution. The goals for the Run II ICD are the same. In this document, the physics arguments for maintaining the ICD are presented, followed by a detailed description of the planned design changes, prototype tests, construction, installation, and commissioning of the device for the Run II D0 detector. Estimates of costs and schedule can be found on //DOSERVER2/Operations/Upgrade Project/ subareas available via DZERO's WinFrame Program Manager. This detector is not intended to provide any ''L0'' capabilities (for luminosity monitoring), or to provide any EM coverage in the intermediate region, or to provide additional coverage in the intermediate regions, unlike previous upgrades proposed in this detector region. The ICD upgrade described here maintains most of the Run I capabilities in a high magnetic field environment

  12. Revisiting Desensitization and Allergen Immunotherapy Concepts for the International Classification of Diseases (ICD)-11.

    Science.gov (United States)

    Tanno, Luciana Kase; Calderon, Moises A; Papadopoulos, Nikolaos G; Sanchez-Borges, Mario; Rosenwasser, Lanny J; Bousquet, Jean; Pawankar, Ruby; Sisul, Juan Carlos; Cepeda, Alfonso Mario; Li, James; Muraro, Antonella; Fineman, Stanley; Sublett, James L; Katelaris, Constance H; Chang, Yoon-Seok; Moon, Hee-Bom; Casale, Thomas; Demoly, Pascal

    2016-01-01

    Allergy and hypersensitivity intervention management procedures, such as desensitization and/or tolerance induction and immunotherapy, have not been pondered up to now in the content of International Classification of Diseases (ICD) context because the focus has been on prioritizing the condition implementations. Tremendous efforts have been devoted to implementing allergic and hypersensitivity conditions in the forthcoming ICD-11. However, we consider that it is crucial now to have nomenclature and classification universally accepted for these procedures to be able to provide scientifically consistent proposals into the new ICD-11 platform for the best practice parameters of our specialty. With the aim of promoting a harmonized comprehension and aligning it with the ICD-11 revision, we have reviewed the definitions and concepts currently used for desensitization and/or tolerance induction and immunotherapy. We strongly believe that this review is a key instrument to support the allergy specialty identity into the ICD-11 framework and serves as a platform to perform positive quality improvement in clinical practice. Copyright © 2016 American Academy of Allergy, Asthma & Immunology. All rights reserved.

  13. Internal defibrillation: where we have been and where we should be going?

    Science.gov (United States)

    Lévy, Samuel

    2005-08-01

    Internal cardioversion has been developed as an alternative technique for patients who are resistant to external DC cardioversion of atrial fibrillation (AF) and was found to be associated with higher success rates. It used initially high energies (200-300 J) delivered between an intracardiac catheter and a backplate. Subsequent studies have shown that it is possible to terminate with energies of 1 to 6 Joules, paroxysmal or induced AF in 90 percent of patients and persistent AF in 75 percent of patients, using biphasic shocks delivered between a right atrium-coronary sinus vectors. Consequently, internal atrial defibrillation can be performed under sedation only without the need for general anesthesia. Recently developed external defibrillators, capable of delivering biphasic shocks, have increased the success rates of external cardioversion and reduced the need for internal cardioversion. However, internal defibrillation is still useful in overweight or obese patients, in patients with chronic obstructive pulmonary disease or asthma who are more difficult to defibrillate, and in patients with implanted devices which may be injured by high energy shocks. Low energy internal defibrillation has also proven to be safe and this has prompted the development of implantable devices for terminating AF. The first device used was the Metrix system, a stand-alone atrial defibrillator (without ventricular defibrillation) which was found to be safe and effective in selected groups of patients. Unfortunately, this device is no longer being marketed. Only double chamber defibrillators with pacing capabilities are presently available: the Medtronic GEM III AT, an updated version of the Jewel AF and the Guidant PRIZM AVT. These devices can be patient-activated or programmed to deliver automatically ounce atrial tachyarrhythmias are detected, therapies including pacing or/and shocks. Attempts to define the group of patients who might benefit from these devices are described but the

  14. Tourette and tic disorders in ICD-11: standing at the diagnostic crossroads.

    Science.gov (United States)

    Woods, Douglas W; Thomsen, Per H

    2014-01-01

    This article reflects discussion by the WHO ICD-11 Working Group on the Classification of Obsessive-Compulsive and Related Disorders. After reviewing the historical classification of tic disorders, this article discusses their placement in ICD-11. Existing problems with diagnostic labels and criteria, appropriate placement of the tic disorders category within the ICD-11 system, and pragmatic factors affecting classification are reviewed. The article ends with recommendations to (a) maintain consistency with the DSM-5 diagnostic labels for tic disorders, (b) add a minimum duration guideline for a provisional tic disorder diagnosis, (c) remove the multiple motor tic guideline for the diagnosis of Tourette disorder, and (d) co-parent the tic disorder diagnoses in the disorders of the nervous system and the mental and behavioral disorders categories, with secondary co-parenting in the obsessive-compulsive and related disorders and neurodevelopmental disorders sections.

  15. Tourette and tic disorders in ICD-11: standing at the diagnostic crossroads

    Directory of Open Access Journals (Sweden)

    Douglas W. Woods

    2014-01-01

    Full Text Available This article reflects discussion by the WHO ICD-11 Working Group on the Classification of Obsessive-Compulsive and Related Disorders. After reviewing the historical classification of tic disorders, this article discusses their placement in ICD-11. Existing problems with diagnostic labels and criteria, appropriate placement of the tic disorders category within the ICD-11 system, and pragmatic factors affecting classification are reviewed. The article ends with recommendations to (a maintain consistency with the DSM-5 diagnostic labels for tic disorders, (b add a minimum duration guideline for a provisional tic disorder diagnosis, (c remove the multiple motor tic guideline for the diagnosis of Tourette disorder, and (d co-parent the tic disorder diagnoses in the disorders of the nervous system and the mental and behavioral disorders categories, with secondary co-parenting in the obsessive-compulsive and related disorders and neurodevelopmental disorders sections.

  16. Obsessive compulsive and related disorders: comparing DSM-5 and ICD-11.

    Science.gov (United States)

    Marras, Anna; Fineberg, Naomi; Pallanti, Stefano

    2016-08-01

    Obsessive-compulsive disorder (OCD) has been recognized as mainly characterized by compulsivity rather than anxiety and, therefore, was removed from the anxiety disorders chapter and given its own in both the American Psychiatric Association (APA) Diagnostic and Statistical Manual of Mental Disorders (DSM-5) and the Beta Draft Version of the 11th revision of the World Health Organization (WHO) International Classification of Diseases (ICD-11). This revised clustering is based on increasing evidence of common affected neurocircuits between disorders, differently from previous classification systems based on interrater agreement. In this article, we focus on the classification of obsessive-compulsive and related disorders (OCRDs), examining the differences in approach adopted by these 2 nosological systems, with particular attention to the proposed changes in the forthcoming ICD-11. At this stage, notable differences in the ICD classification are emerging from the previous revision, apparently converging toward a reformulation of OCRDs that is closer to the DSM-5.

  17. Uncommon combinations of ICD10-PCS or ICD-9-CM operative procedure codes account for most inpatient surgery at half of Texas hospitals.

    Science.gov (United States)

    O'Neill, Liam; Dexter, Franklin; Park, Sae-Hwan; Epstein, Richard H

    2017-09-01

    Recently, there has been interest in activity-based cost accounting for inpatient surgical procedures to facilitate "value based" analyses. Research 10-20years ago, performed using data from 3 large teaching hospitals, found that activity-based cost accounting was practical and useful for modeling surgeons and subspecialties, but inaccurate for individual procedures. We hypothesized that these older results would apply to hundreds of hospitals, currently evaluable using administrative databases. Observational study. State of Texas hospital discharge abstract data for 1st quarter of 2016, 4th quarter of 2015, 1st quarter of 2015, and 4th quarter of 2014. Discharged from an acute care hospital in Texas with at least 1 major therapeutic ("operative") procedure. Counts of discharges for each procedure or combination of procedures, classified by ICD-10-PCS or ICD-9-CM. At the average hospital, most surgical discharges were for procedures performed at most once a month at the hospital (54%, 95% confidence interval [CI] 51% to 55%). At the average hospital, approximately 90% of procedures were performed at most once a month at the hospital (93%, CI 93% to 94%). The percentages were insensitive to the quarter of the year. The percentages were 3% to 6% greater with ICD-10-PCS than for the superseded ICD 9 CM. There are many different procedure codes, and many different combinations of codes, relative to the number of different hospital discharges. Since most procedures at most hospitals are performed no more than once a month, activity-based cost accounting with a sample size sufficient to be useful is impractical for the vast majority of procedures, in contrast to analysis by surgeon and/or subspecialty. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Differences between out-of-hospital cardiac arrest in residential and public locations and implications for public-access defibrillation

    DEFF Resear