WorldWideScience

Sample records for cardioverter defibrillator icd

  1. Living with Your Implantable Cardioverter Defibrillator (ICD)

    Science.gov (United States)

    ... you take and when. Download a printable medication tracker . Learn more about arrhythmia medications in general. Understanding ... and dentists that you have an ICD. Follow activity instructions Follow the restrictions on activity and any ...

  2. Psychosocial impact of implantable cardioverter defibrillators (ICD) in young adults with Tetralogy of Fallot.

    NARCIS (Netherlands)

    Opic, P.; Utens, E.M.; Moons, P.; Theuns, D.A.; Dijk, A.P.J. van; Hoendermis, E.S.; Vliegen, H.W.; Groot, N.M. de; Witsenburg, M.; Schalij, M.; Roos-Hesselink, J.W.

    2012-01-01

    OBJECTIVE: To investigate the psychosocial impact of having an implantable cardioverter defibrillator (ICD) in adults with Tetralogy of Fallot (ToF). METHODS: Included were 26 ToF-patients with an ICD (age 44 +/- 12 years), and two control groups consisting of 28 ToF-patients without an ICD (age 40

  3. Psychosocial impact of implantable cardioverter defibrillators (ICD) in young adults with Tetralogy of Fallot

    NARCIS (Netherlands)

    Opic, Petra; Utens, Elisabeth M. W. J.; Moons, Philip; Theuns, Dominic A. M. J.; van Dijk, Arie P. J.; Hoendermis, Elke S.; Vliegen, Hubert W.; de Groot, Natasja M. S.; Witsenburg, Maarten; Schalij, Martin; Roos-Hesselink, Jolien W.

    2012-01-01

    To investigate the psychosocial impact of having an implantable cardioverter defibrillator (ICD) in adults with Tetralogy of Fallot (ToF). Included were 26 ToF-patients with an ICD (age 44 +/- A 12 years), and two control groups consisting of 28 ToF-patients without an ICD (age 40 +/- A 10 years) an

  4. Psychosocial impact of implantable cardioverter defibrillators (ICD) in young adults with Tetralogy of Fallot

    NARCIS (Netherlands)

    P. Opic (Petra); E.M.W.J. Utens (Elisabeth); P. Moons (Philip); D.A.M.J. Theuns (Dominic); A.P.J. van Dijk (Arie); E.S. Hoendermis (Elke); H.W. Vliegen (Hubert); N. de Groot (Natasja); M. Witsenburg (Maarten); M.J. Schalij (Martin Jan); J.W. Roos-Hesselink (Jolien)

    2012-01-01

    textabstractObjective To investigate the psychosocial impact of having an implantable cardioverter defibrillator (ICD) in adults with Tetralogy of Fallot (ToF). Methods Included were 26 ToF-patients with an ICD (age 44 ± 12 years), and two control groups consisting of 28 ToF-patients without an ICD

  5. Non-pharmacological treatment of heart failure: Implantable cardioverter defibrillator (ICD) and cardiac resynchronisation therapy

    NARCIS (Netherlands)

    Van Gelder, I.C.; Smit, M.D.; Nieuwland, W; Van Veldhuisen, D.J.

    2006-01-01

    The non-pharmacological therapy of heart failure, in particular an implantable cardioverter defibrillator (ICD) and cardiac resynchronisation therapy or biventricular stimulation, improves symptoms and survival in patients with heart failure. - An ICD is indicated in many patients with heart failure

  6. Who Needs an Implantable Cardioverter Defibrillator?

    Science.gov (United States)

    ... this page from the NHLBI on Twitter. Who Needs an Implantable Cardioverter Defibrillator? Implantable cardioverter defibrillators (ICDs) ... before. Some people who have heart failure may need a CRT-D device. This device combines a ...

  7. Cognitive behavioral therapy (CBT in a Patient with Implantable Cardioverter Defibrillator (ICD and Posttraumatic stress disorder(PTSD.

    Directory of Open Access Journals (Sweden)

    Sahar Ansari

    2014-09-01

    Full Text Available The implantable cardioverter defibrillator (ICD has currently become the standard treatment for preventing sudden cardiac death. There are some psychological consequences in patients with ICD such as posttraumatic stress disorder (PTSD after the shocks induced by ICD. This report aimed to present the case of a 54-year-old man with ICD who had developed PTSD; his PTSD was treated, using cognitive-behavioral psychotherapy consisting of relaxation, mindfulness and problem solving techniques. In patients with ICD who are experiencing PTSD using cognitive behavioral interventions may be helpful to reduce their psychological sufferings.

  8. Cognitive behavioral therapy (CBT) in a Patient with Implantable Cardioverter Defibrillator (ICD) and Posttraumatic stress disorder(PTSD).

    Science.gov (United States)

    Ansari, Sahar; Arbabi, Mohammad

    2014-07-01

    The implantable cardioverter defibrillator (ICD) has currently become the standard treatment for preventing sudden cardiac death. There are some psychological consequences in patients with ICD such as posttraumatic stress disorder (PTSD) after the shocks induced by ICD. This report aimed to present the case of a 54-year-old man with ICD who had developed PTSD; his PTSD was treated, using cognitive-behavioral psychotherapy consisting of relaxation, mindfulness and problem solving techniques. In patients with ICD who are experiencing PTSD using cognitive behavioral interventions may be helpful to reduce their psychological sufferings.

  9. Optimal Implantable Cardioverter Defibrillator Programming.

    Science.gov (United States)

    Shah, Bindi K

    Optimal programming of implantable cardioverter defibrillators (ICDs) is essential to appropriately treat ventricular tachyarrhythmias and to avoid unnecessary and inappropriate shocks. There have been a series of large clinical trials evaluating tailored programming of ICDs. We reviewed the clinical trials evaluating ICD therapies and detection, and the consensus statement on ICD programming. In doing so, we found that prolonged ICD detection times, higher rate cutoffs, and antitachycardia pacing (ATP) programming decreases inappropriate and painful therapies in a primary prevention population. The use of supraventricular tachyarrhythmia discriminators can also decrease inappropriate shocks. Tailored ICD programming using the knowledge gained from recent ICD trials can decrease inappropriate and unnecessary ICD therapies and decrease mortality.

  10. The NO Regular Defibrillation testing In Cardioverter Defibrillator Implantation (NORDIC ICD) trial

    DEFF Research Database (Denmark)

    Bänsch, Dietmar; Bonnemeier, Hendrik; Brandt, Johan

    2015-01-01

    was standardized across all participating centres. After inducing a fast ventricular tachycardia (VT) with a heart rate ≥240 b.p.m. or ventricular fibrillation (VF) with a low-energy T-wave shock, DF was attempted with an initial 15 J shock. If the shock reversed the VT or VF, DF testing was considered successful...... and terminated. If unsuccessful, two effective 24 J shocks were administered. If DF was unsuccessful, the system was reconfigured and another DF testing was performed. An ICD shock energy of 40 J had to be programmed in all patients for treatment of spontaneous VT/VF episodes. The primary endpoint...... was the average efficacy of the first ICD shock for all true VT/VF episodes in each patient during follow-up. The secondary endpoints included the frequency of system revisions, total fluoroscopy, implantation time, procedural serious adverse events, and all-cause, cardiac, and arrhythmic mortality during follow...

  11. Concerns about the implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van Domburg, Ron T; Theuns, Dominic A M J

    2005-01-01

    Patients with an implantable cardioverter defibrillator (ICD) are at increased risk of anxiety disorders. In turn, anxiety has been identified as a precipitant of ventricular arrhythmias. Anxiety may in part be attributed to concerns about the ICD firing, but the relationship between ICD concerns...

  12. Outcomes in African-Americans Undergoing Cardioverter Defibrillators Implantation for Primary Prevention of Sudden Cardiac Death: Findings from The Prospective Observational Study of Implantable Cardioverter-Defibrillators (PROSE-ICD)

    Science.gov (United States)

    Zhang, Yiyi; Kennedy, Robert; Blasco-Colmenares, Elena; Butcher, Barbara; Norgard, Sanaz; Eldadah, Zayd; Dickfeld, Timm; Ellenbogen, Kenneth A.; Marine, Joseph E.; Guallar, Eliseo; Tomaselli, Gordon F.; Cheng, Alan

    2014-01-01

    Background Implantable cardioverter defibrillators (ICDs) reduce the risk of death in patients with left ventricular dysfunction. Little is known regarding the benefit of this therapy in African-Americans (AA). Objective To determine the association between African-American race and outcomes in a cohort of primary prevention cardioverter defibrillators (ICD) patients. Methods We conducted a prospective cohort study of patients with systolic heart failure who underwent ICD implantation for primary prevention of sudden cardiac death. The primary endpoint was appropriate ICD shock defined as a shock for rapid ventricular tachyarrhythmias. The secondary endpoint was all-cause mortality. Results There were 1,189 patients (447 AAs and 712 non-AAs) enrolled. Over a median follow-up of 5.1 years, a total of 137 patients experienced an appropriate ICD shock, and 343 died (294 of whom died without receiving an appropriate ICD shock). The multivariate adjusted hazard ratios (95% CI) comparing AAs vs. non-AAs were 1.24 (0.96 to 1.59) for all-cause mortality, 1.33 (1.02, 1.74) for all-cause mortality without receiving appropriate ICD shock, and 0.78 (0.51, 1.19) for appropriate ICD shock. Ejection fraction, diabetes, and hypertension appeared to explain 24.1% (10.1 to 69.5%), 18.7% (5.3 to 58.0%), and 13.6% (3.8 to 53.6%) of the excess risk of mortality in AAs, with a large proportion of the mortality difference remains unexplained. Conclusions In patients with primary prevention ICDs, AAs had an increased risk of dying without receiving an appropriate ICD shock compared to non-AAs. PMID:24793459

  13. [The implantable cardioverter-defibrillator: sometimes necessary

    NARCIS (Netherlands)

    Smeets, J.L.R.M.

    2004-01-01

    The implantable cardioverter-defibrillator (ICD) is used in patients who are at risk for ventricular fibrillation after having suffered from a myocardial infarction. Initially, patient selection was limited to survivors of impending sudden death with coronary artery disease. Later, ICD implantation

  14. An Entirely Subcutaneous Implantable Cardioverter-Defibrillator

    NARCIS (Netherlands)

    Bardy, Gust H.; Smith, Warren M.; Hood, Margaret A.; Crozier, Ian G.; Melton, Iain C.; Jordaens, Luc; Theuns, Dominic; Park, Robert E.; Wright, David J.; Connelly, Derek T.; Fynn, Simon P.; Murgatroyd, Francis D.; Sperzel, Johannes; Neuzner, Joerg; Spitzer, Stefan G.; Ardashev, Andrey V.; Oduro, Amo; Boersma, Lucas; Maass, Alexander H.; Van Gelder, Isabelle C.; Wilde, Arthur A.; van Dessel, Pascal F.; Knops, Reinoud E.; Barr, Craig S.; Lupo, Pierpaolo; Cappato, Riccardo; Grace, Andrew A.

    2010-01-01

    BACKGROUND Implantable cardioverter-defibrillators (ICDs) prevent sudden death from cardiac causes in selected patients but require the use of transvenous lead systems. To eliminate the need for venous access, we designed and tested an entirely subcutaneous ICD system. METHODS First, we conducted tw

  15. An entirely subcutaneous implantable cardioverter-defibrillator

    NARCIS (Netherlands)

    G.H. Bardy (Gust); W.M. Smith (Warren); A.M. Hood (Margaret); I.G. Crozier (Ian); I.C. Melton (Iain Craig); L.J.L.M. Jordaens (Luc); D.A.M.J. Theuns (Dominic); E. Park (Robert); D.J. Wright (David Justin); D.T. Connelly (Derek); S.P. Fynn (Simon Patrick); F.D. Murgatroyd (Francis); J. Sperzel (Johannes); J. Neuzner (Jörg); S.G. Spitzer (Stefan); A.V. Ardashev (Andrey); A. Oduro (Amo); L. Boersma (Lucas); A.H. Maass (Alexander); I.C. van Gelder (Isabelle); A.A.M. Wilde (Arthur); P.F.H.M. van Pascal; R.E. Knops (Reinoud); C.S. Barr (Craig); P. Lupo (Pierpaolo); R. Cappato (Riccardo); A.A. Grace (Andrew)

    2010-01-01

    textabstractBACKGROUND: Implantable cardioverter-defibrillators (ICDs) prevent sudden death from cardiac causes in selected patients but require the use of transvenous lead systems. To eliminate the need for venous access, we designed and tested an entirely subcutaneous ICD system. METHODS: First, w

  16. Programmed Ventricular Stimulation to Risk Stratify for Early Cardioverter-Defibrillator Implantation to Prevent Tachyarrhythmias following Acute Myocardial Infarction (PROTECT-ICD): Trial Protocol, Background and Significance.

    Science.gov (United States)

    Zaman, Sarah; Taylor, Andrew J; Stiles, Martin; Chow, Clara; Kovoor, Pramesh

    2016-11-01

    The 'Programmed Ventricular Stimulation to Risk Stratify for Early Cardioverter-Defibrillator Implantation to Prevent Tachyarrhythmias following Acute Myocardial Infarction' (PROTECT-ICD) trial is an Australian-led multicentre randomised controlled trial targeting prevention of sudden cardiac death in patients who have at least moderately reduced cardiac function following a myocardial infarct (MI). The primary objective of the trial is to assess whether electrophysiological study to guide prophylactic implantation of an implantable cardioverter-defibrillator (ICD) early following MI (first 40 days) will lead to a significant reduction in sudden cardiac death and non-fatal arrhythmia. The secondary objective is to assess the utility of cardiac MRI (CMR) in assessing early myocardial characteristics, and its predictive value for both inducible ventricular tachycardia (VT) at EPS and SCD/ non-fatal arrhythmia at follow-up.

  17. Methodological limitations of psychosocial interventions in patients with an implantable cardioverter-defibrillator (ICD A systematic review

    Directory of Open Access Journals (Sweden)

    Ockene Ira S

    2009-12-01

    Full Text Available Abstract Background Despite the potentially life-saving benefits of the implantable cardioverter-defibrillator (ICD, a significant group of patients experiences emotional distress after ICD implantation. Different psychosocial interventions have been employed to improve this condition, but previous reviews have suggested that methodological issues may limit the validity of such interventions. Aim: To review the methodology of previously published studies of psychosocial interventions in ICD patients, according to CONSORT statement guidelines for non-pharmacological interventions, and provide recommendations for future research. Methods We electronically searched the PubMed, PsycInfo and Cochrane databases. To be included, studies needed to be published in a peer-reviewed journal between 1980 and 2008, to involve a human population aged 18+ years and to have an experimental design. Results Twelve studies met the eligibility criteria. Samples were generally small. Interventions were very heterogeneous; most studies used cognitive behavioural therapy (CBT and exercise programs either as unique interventions or as part of a multi-component program. Overall, studies showed a favourable effect on anxiety (6/9 and depression (4/8. CBT appeared to be the most effective intervention. There was no effect on the number of shocks and arrhythmic events, probably because studies were not powered to detect such an effect. Physical functioning improved in the three studies evaluating this outcome. Lack of information about the indication for ICD implantation (primary vs. secondary prevention, limited or no information regarding use of anti-arrhythmic (9/12 and psychotropic (10/12 treatment, lack of assessments of providers' treatment fidelity (12/12 and patients' adherence to the intervention (11/12 were the most common methodological limitations. Conclusions Overall, this review supports preliminary evidence of a positive effect of psychosocial interventions

  18. Results of ENHANCED Implantable Cardioverter Defibrillator Programming to Reduce Therapies and Improve Quality of Life (from the ENHANCED-ICD Study).

    Science.gov (United States)

    Mastenbroek, Mirjam H; Pedersen, Susanne S; van der Tweel, Ingeborg; Doevendans, Pieter A; Meine, Mathias

    2016-02-15

    Novel implantable cardioverter defibrillator (ICD) discrimination algorithms and programming strategies have significantly reduced the incidence of inappropriate shocks, but there are still gains to be made with respect to reducing appropriate but unnecessary antitachycardia pacing (ATP) and shocks. We examined whether programming a number of intervals to detect (NID) of 60/80 for ventricular tachyarrhythmia (VT)/ventricular fibrillation (VF) detection was safe and the impact of this strategy on (1) adverse events related to ICD shocks and syncopal events; (2) ATPs/shocks; and (3) patient-reported outcomes. The "ENHANCED Implantable Cardioverter Defibrillator programming to reduce therapies and improve quality of life" study (ENHANCED-ICD study) was a prospective, safety-monitoring study enrolling 60 primary and secondary prevention patients at the University Medical Center Utrecht. Patients implanted with any type of ICD with SmartShock technology and aged 18 to 80 years were eligible to participate. In all patients, a prolonged NID 60/80 was programmed. The cycle length for VT/fast VT/VF was 360/330/240 ms, respectively. Programming a NID 60/80 proved safe for ICD patients. Because of the new programming strategy, unnecessary ICD therapy was prevented in 10% of ENHANCED-ICD patients during a median follow-up period of 1.3 years. With respect to patient-reported outcomes, levels of distress were highest and perceived health status lowest at the time of implantation, which both gradually improved during follow-up. In conclusion, the ENHANCED-ICD study demonstrates that programming a NID 60/80 for VT/VF detection is safe for ICD patients and does not negatively impact their quality of life.

  19. Pre-implantation implantable cardioverter defibrillator concerns and Type D personality increase the risk of mortality in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van den Broek, Krista C; Erdman, Ruud A M;

    2010-01-01

    Little is known about the influence of psychological factors on prognosis in implantable cardioverter defibrillator (ICD) patients. We examined the influence of the distressed personality (Type D) and pre-implantation device concerns on short-term mortality in ICD patients.......Little is known about the influence of psychological factors on prognosis in implantable cardioverter defibrillator (ICD) patients. We examined the influence of the distressed personality (Type D) and pre-implantation device concerns on short-term mortality in ICD patients....

  20. Dental management of a patient fitted with subcutaneous Implantable Cardioverter Defibrillator device and concomitant warfarin treatment

    OpenAIRE

    Altaf Hussain Shah; Hesham Saleh Khalil; Mohammed Zaheer Kola

    2015-01-01

    Automated Implantable Cardioverter Defibrillators (AICD), simply known as an Implantable Cardioverter Defibrillator (ICD), has been used in patients for more than 30 years. An Implantable Cardioverter Defibrillator (ICD) is a small battery-powered electrical impulse generator that is implanted in patients who are at a risk of sudden cardiac death due to ventricular fibrillation, ventricular tachycardia or any such related event. Typically, patients with these types of occurrences are on antic...

  1. Living with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S; Knudsen, Charlotte; Dilling, Karen;

    2017-01-01

    Hospital were asked to complete a purpose-designed and standardized set of questionnaires. The level of satisfaction with information provision was high; only 13.1% were dissatisfied. Psychological support for patients (39.9%), their relatives (43.1%), and deactivation of the ICD towards end of life (47......AIMS: The clinical management and care of patients with an implantable cardioverter defibrillator (ICD) has shifted from face-to-face in-clinic visits to remote monitoring. Reduced interactions between patients and healthcare professionals may impede patients' transition to adapting post......-implant. We examined patients' needs and preferences for information provision and care options and overall satisfaction with treatment. METHODS AND RESULTS: Patients implanted with a first-time ICD or defibrillator with cardiac resynchronization therapy (n = 389) within the last 2 years at Odense University...

  2. Prognostic importance of distressed (Type D) personality and shocks in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Denollet, Johan; Tekle, Fetene B; Pedersen, Susanne S.;

    2013-01-01

    Clinical trials have shown the benefit of implantable cardioverter defibrillator (ICD) treatment. In this study, we examined the importance of chronic psychological distress and device shocks among ICD patients seen in clinical practice....

  3. Somatosensory amplification mediates sex differences in psychological distress among cardioverter-defibrillator patients

    DEFF Research Database (Denmark)

    Versteeg, Henneke; Baumert, Jens; Kolb, Christof

    2010-01-01

    The present study examined whether female patients with an implantable cardioverter defibrillator (ICD) report more psychological distress than male patients, and whether somatosensory amplification mediates this relationship. Design: Consecutive ICD patients (N = 241; 33% women) participating...

  4. Anxiety and risk of ventricular arrhythmias or mortality in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; Pedersen, Susanne S.; van den Broek, Krista C;

    2013-01-01

    A subgroup of patients with an implantable cardioverter defibrillator (ICD) experiences anxiety after device implantation. The purpose of the present study was to evaluate whether anxiety is predictive of ventricular arrhythmias and all-cause mortality 1 year post ICD implantation.......A subgroup of patients with an implantable cardioverter defibrillator (ICD) experiences anxiety after device implantation. The purpose of the present study was to evaluate whether anxiety is predictive of ventricular arrhythmias and all-cause mortality 1 year post ICD implantation....

  5. Magnets and implantable cardioverter defibrillators: What′s the problem?

    Directory of Open Access Journals (Sweden)

    Yiliam F Rodriguez-Blanco

    2013-01-01

    Full Text Available A growing number of surgical patients present to the operating room with implantable cardioverter defibrillators (ICD. Peri-operative care of these patients dictates that ICD function be suspended for many surgical procedures to avoid inappropriate, and possibly harmful, ICD therapy triggered by electromagnetic interference (EMI. An alternative to reprogramming the ICD is the use of a magnet to temporarily suspend its function. However, this approach is not without complications. We report a case where magnet use failed to inhibit ICD sensing of EMI, and a shock was delivered to the patient. Measures to decrease EMI, controversies regarding magnet use, and expert recommendations are discussed.

  6. Magnets and implantable cardioverter defibrillators: what's the problem?

    Science.gov (United States)

    Rodriguez-Blanco, Yiliam F; Souki, Fouad; Tamayo, Evelyn; Candiotti, Keith

    2013-01-01

    A growing number of surgical patients present to the operating room with implantable cardioverter defibrillators (ICD). Peri-operative care of these patients dictates that ICD function be suspended for many surgical procedures to avoid inappropriate, and possibly harmful, ICD therapy triggered by electromagnetic interference (EMI). An alternative to reprogramming the ICD is the use of a magnet to temporarily suspend its function. However, this approach is not without complications. We report a case where magnet use failed to inhibit ICD sensing of EMI, and a shock was delivered to the patient. Measures to decrease EMI, controversies regarding magnet use, and expert recommendations are discussed.

  7. Interference of electronic apex locators with implantable cardioverter defibrillators

    NARCIS (Netherlands)

    Idzahi, K.; de Cock, C.C.; Shemesh, H.; Brand, H.S.

    2014-01-01

    Introduction The purpose of this in vitro study was to evaluate the potential electromagnetic interference of electronic apex locators (EALs) on implantable cardioverter defibrillators (ICDs). Methods Four different EALs were tested for their ability to interfere with the correct function of 3 diffe

  8. Implantable cardioverter defibrillator - discharge

    Science.gov (United States)

    ... hair dryer, stove, CD player, remote controls, and microwave. There are several devices you should keep at ... Tell your provider about every shock you feel from your ICD. The settings of your ICD may need to be adjusted, or your medicines may need to ...

  9. Clinical efficacy and safety of an implantable cardioverter-defibrillator lead with a floating atrial sensing dipole

    DEFF Research Database (Denmark)

    Safak, Erdal; Schmitz, Dietmar; Konorza, Thomas;

    2013-01-01

    The concept of a single-lead implantable cardioverter-defibrillator (ICD), with a floating dipole, has been proven safe and functional.......The concept of a single-lead implantable cardioverter-defibrillator (ICD), with a floating dipole, has been proven safe and functional....

  10. Implantable cardioverter-defibrillator

    Science.gov (United States)

    ... the heart to beat in a more coordinated fashion. Why the Procedure is Performed An ICD is ... Controlling your high blood pressure Dietary fats explained Fast food tips Heart attack - discharge Heart disease - risk ...

  11. Making post-mortem implantable cardioverter defibrillator explantation safe

    OpenAIRE

    Räder, Sune B.E.W.; Zeijlemaker, Volkert; Pehrson, Steen; Svendsen, Jesper H

    2009-01-01

    Aims The aim of this study is to investigate whether protection with rubber or plastic gloves during post-mortem explantation of an implantable cardioverter defibrillator (ICD) offers enough protection for the explanting operator during a worst-case scenario (i.e. ICD shock). Methods and results We investigated the insulating properties of rubber and plastic gloves (double layer) within the first 60 min exposure (mimicking the maximum time of an explantation procedure) to saline (simulating t...

  12. Behavioral interventions in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; Burg, Matthew M; Pedersen, Susanne S.

    2013-01-01

    The implantable cardioverter defibrillator (ICD) is the first-line treatment for primary and secondary prevention of sudden cardiac death. A subgroup of patients experience psychological distress postimplant, and no clear evidence base exists regarding how best to address patients' needs. The aim...... of this critical review is to provide an overview of behavioral interventions in ICD patients to date, and to delineate directions for future research using lessons learned from the ongoing RISTA and WEBCARE trials....

  13. Implantable cardioverter defibrillator specific rehabilitation improves health cost outcomes

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Zwisler, Ann-Dorthe; Koch, Mette Bjerrum;

    2015-01-01

    ) were randomized (1:1) to comprehensive cardiac rehabilitation or usual care. Outcomes were measured by implantable cardioverter defibrillator therapy history from patient records and national register follow-up on mortality, hospital admissions and costs. RESULTS: No significant differences were found...... was -6,789 USD/-5,593 Euro in favour of rehabilitation. CONCLUSION: No long-term health outcome benefits were found for the rehabilitation programme. However, the rehabilitation programme resulted in a reduction in total attributable direct costs.......OBJECTIVE: The Copenhagen Outpatient ProgrammE - implantable cardioverter defibrillator (COPE-ICD) trial included patients with implantable cardioverter defibrillators in a randomized controlled trial of rehabilitation. After 6-12 months significant differences were found in favour...

  14. Optimizing defibrillation waveforms for ICDs.

    Science.gov (United States)

    Kroll, Mark W; Swerdlow, Charles D

    2007-04-01

    While no simple electrical descriptor provides a good measure of defibrillation efficacy, the waveform parameters that most directly influence defibrillation are voltage and duration. Voltage is a critical parameter for defibrillation because its spatial derivative defines the electrical field that interacts with the heart. Similarly, waveform duration is a critical parameter because the shock interacts with the heart for the duration of the waveform. Shock energy is the most often cited metric of shock strength and an ICD's capacity to defibrillate, but it is not a direct measure of shock effectiveness. Despite the physiological complexities of defibrillation, a simple approach in which the heart is modeled as passive resistor-capacitor (RC) network has proved useful for predicting efficient defibrillation waveforms. The model makes two assumptions: (1) The goal of both a monophasic shock and the first phase of a biphasic shock is to maximize the voltage change in the membrane at the end of the shock for a given stored energy. (2) The goal of the second phase of a biphasic shock is to discharge the membrane back to the zero potential, removing the charge deposited by the first phase. This model predicts that the optimal waveform rises in an exponential upward curve, but such an ascending waveform is difficult to generate efficiently. ICDs use electronically efficient capacitive-discharge waveforms, which require truncation for effective defibrillation. Even with optimal truncation, capacitive-discharge waveforms require more voltage and energy to achieve the same membrane voltage than do square waves and ascending waveforms. In ICDs, the value of the shock output capacitance is a key intermediary in establishing the relationship between stored energy-the key determinant of ICD size-and waveform voltage as a function of time, the key determinant of defibrillation efficacy. The RC model predicts that, for capacitive-discharge waveforms, stored energy is minimized

  15. Implantable cardioverter-defibrillator oversensing due to electric shock

    Directory of Open Access Journals (Sweden)

    Jurčević Ružica

    2010-01-01

    Full Text Available Introduction. We described the first case of oversensing due to electric shock in Serbia, in a 54-year-old man who had implantable cardioverter-defibrillator (ICD. Case Outline. In July 2002, the patient had acute anteroseptal myocardial infarction and ventricular fibrillation (VF which was terminated with six defibrillation shocks of 360 J. Coronary angiography revealed 30% stenosis of circumflex artery, the left anterior descending coronary artery was recanalized and the right coronary artery was without stenosis. Left ventricular ejection fraction was 20%. In December 2003, an electrophysiology study was performed and ventricular tachycardia (VT was induced and terminated with 200 J defibrillation shock. Single chamber ICD Medtronic Gem III VR was implanted in January 2004 and defibrillation threshold was 12 J. The patient was followed up during three years every three months and there were no VT/VF episodes and VT/VF therapies. In December 2007, the patient experienced electric shock through the fork while he was making barbecue on the electric grill. ICD recognized this event in VF zone (oversensing and delivered defibrillation shock of 18 J. The electrogram of the episode showed ventricular sensing - intrinsic sinus rhythm with electric shock potentials which were misidentified as VF. After charge time of 3.16 seconds, ICD delivered defibrillation shock and sinus rhythm was still present. Conclusion. Oversensing of ICD has different aetiology and the most common cause is supraventricular tachyarrhythmia.

  16. Making post-mortem implantable cardioverter defibrillator explantation safe

    DEFF Research Database (Denmark)

    Räder, Sune B E W; Zeijlemaker, Volkert; Pehrson, Steen;

    2009-01-01

    AIMS: The aim of this study is to investigate whether protection with rubber or plastic gloves during post-mortem explantation of an implantable cardioverter defibrillator (ICD) offers enough protection for the explanting operator during a worst-case scenario (i.e. ICD shock). METHODS AND RESULTS...... that the resting voltage over the operating person would not exceed 50 V. CONCLUSION: The use of intact medical gloves made of latex, neoprene, or plastic eliminates the potential electrical risk during explantation of an ICD. Two gloves on each hand offer sufficient protection. We will recommend the use...

  17. Attrition and Adherence in a Web-Based Distress Management Program for Implantable Cardioverter Defibrillator Patients (WEBCARE): Randomized Controlled Trial

    DEFF Research Database (Denmark)

    Habibovic, M.; Cuijpers, P.; Alings, M.;

    2014-01-01

    Background: WEB-Based Distress Management Program for Implantable CARdioverter defibrillator Patients (WEBCARE) is a Web-based randomized controlled trial, designed to improve psychological well-being in patients with an implantable cardioverter defibrillator (ICD). As in other Web-based trials, ...

  18. The occupational routine of patients implanted with cardioverter-defibrillator

    Directory of Open Access Journals (Sweden)

    Juliana Mannini

    2015-03-01

    Full Text Available Implantable cardioverter-defibrillators (ICD have become a reference as to the standard of care for patients with potentially lethal ventricular arrhythmias. The ICD treats the symptoms of the disease with no impact on its cause; however, the electrical discharge originating from the operating mechanism of this device has been the source of many studies addressing the quality of life of this population. The specific literature points to limitations of patients implanted with cardioverter-defibrillators regarding activities such as working and driving, but little has been discussed whether other areas of occupational performance are also limited. The purpose of this prospective exploratory research, which uses a case study design of quantitative nature, is to know the routine of patients implanted with cardioverter-defibrillator. Fifteen subjects with ICD participated in the study; they were outpatients in the arrhythmia sector of the ‘Clementino Fraga Filho’ University Hospital - HUCFF. The instruments for data collection included an initial interview, SF36 inventory, Role Checklist, and an open question. The results showed interference in the routine occupational performance and occupational roles evaluated, as well as in the fields of mental health and vitality, with greater focus on influences arising from the pathology than the mechanism of the device.

  19. Successful intermuscular implantation of subcutaneous implantable cardioverter defibrillator in a Japanese patient with pectus excavatum.

    Science.gov (United States)

    Kondo, Yusuke; Ueda, Marehiko; Winter, Joachim; Nakano, Miyo; Nakano, Masahiro; Ishimura, Masayuki; Miyazawa, Kazuo; Tateno, Kaoru; Kobayashi, Yoshio

    2017-02-01

    The entirely subcutaneous implantable cardioverter-defibrillator (ICD) system was developed to provide a life-saving defibrillation therapy that does not affect the heart and vasculature. The subcutaneous ICD is preferred over the transvenous ICD for patients with a history of recurrent infection presenting major life-threatening rhythms. In this case report, we describe the first successful intermuscular implantation of a completely subcutaneous ICD in a Japanese patient with pectus excavatum. There were no associated complications with the device implantation or lead positioning. Further, the defibrillation threshold testing did not pose any problem with the abnormal anatomy of the patient.

  20. The dilemma of implantable cardioverter-defibrillator therapy in the geriatric population

    Institute of Scientific and Technical Information of China (English)

    Diana Revenco; James P Morgan; Lana Tsao

    2011-01-01

    Current guidelines for implantable cardioverter-defibrillator(ICD)therapy in heart failure patients were established by multiple device trials;however,very few geriatric patients(patients≥65 years old)were included in these studies.This article explores the controversies of ICD implantation in the geriatric population,management of delivered ICD therapy in this age group,and the end of life care in patients with ICD.

  1. Increased anxiety in partners of patients with a cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; VAN DEN Berg, Martha; Erdman, Ruud A M

    2009-01-01

    The partner of the implantable cardioverter-defibrillator (ICD) patient serves as an important source of support for the patient, which may be hampered if the partner experiences increased distress. We examined (1) potential differences in anxiety and depressive symptoms in ICD patients compared...

  2. Outcome of implantable cardioverter defibrillators in adults with congenital heart disease : a multi-centre study

    NARCIS (Netherlands)

    Yap, Sing-Chien; Roos-Hesselink, Jolien W.; Hoendermis, Elke S.; Budts, Werner; Vliegen, Hubert W.; Mulder, Barbara J. M.; van Dijk, Arie P. J.; Schalij, Martin J.; Drenthen, Willem

    2007-01-01

    Aims To investigate outcome and complications of implantable cardioverter defibrillators (ICDs) in adults with congenital heart disease (CHD) and to identify predictors of (in-) appropriate shocks. Methods and results Sixty-four CHD patients >= 18 years at first ICD implantation [63% tetralogy of Fa

  3. Emotional distress in partners of patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Van Den Broek, Krista C; Habibović, Mirela; Pedersen, Susanne S.

    2010-01-01

    Both patients with an implantable cardioverter defibrillator (ICD) and their partners face challenges when adapting to the ICD. Distress is a burden on its own for partners but may also affect well being and health of patients. This review provides a systematic overview of the literature on psych...

  4. Influence of diabetes mellitus on inappropriate and appropriate implantable cardioverter-defibrillator therapy and mortality in the Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT) Trial

    DEFF Research Database (Denmark)

    Ruwald, Martin H.; Zareba, Wojciech; Jons, Christian;

    2013-01-01

    The relationship between diabetes mellitus and risk of inappropriate or appropriate therapy in patients receiving an implantable cardioverter-defibrillator (ICD) and resynchronization therapy has not been investigated thoroughly. The effect of innovative ICD programming on therapy delivery in the...

  5. Psychological effects of implantable cardioverter defibrillator shocks. A review of study methods

    OpenAIRE

    Manzoni, Gian Mauro; Castelnuovo, Gianluca; Compare, Angelo; Pagnini, Francesco; Essebag, Vidal; Proietti, Riccardo

    2015-01-01

    Background: The implantable cardioverter defibrillator (ICD) saves lives but clinical experience suggests that it may have detrimental effects on mental health. The ICD shock has been largely blamed as the main offender but empirical evidence is not consistent, perhaps because of methodological differences across studies. Objective: To appraise methodologies of studies that assessed the psychological effects of ICD shock and explore associations between methods and results. Data Sources...

  6. Psychological effects of implantable cardioverter defibrillator shocks. A review of study methods.

    OpenAIRE

    Gian Mauro eManzoni; Gianluca eCastelnuovo; Angelo eCompare; Francesco ePagnini; Vidal eEssebag; Riccardo eProietti

    2015-01-01

    BackgroundThe implantable cardioverter defibrillator (ICD) saves lives but clinical experience suggests that it may have detrimental effects on mental health. The ICD shock has been largely blamed as the main offender but empirical evidence is not consistent, perhaps because of methodological differences across studies. ObjectiveTo appraise methodologies of studies that assessed the psychological effects of ICD shock and explore associations between methods and results. Data Sources A compreh...

  7. The Clinical Application and Effect of Implantable Cardioverter Defibrillator(ICD)%经静脉植入埋藏式心脏复律除颤器的临床应用及效果观察

    Institute of Scientific and Technical Information of China (English)

    江自强

    2015-01-01

    Objective:to explore the clinical application and effect of implantable cardioverter defibrillator(icd). Methods:selecting and analyzing 80 cases of malignant ventricular arrhythmia, which are randomly divided into control group (treated with amiodarone) and treatment group(treated with the icd) . then comparing the effects. Results:the overall response rate(rr) of the treatment group is 95%, much higher than the other one(85%)(P0.05);yet after treatment, the heart rate of the treatment group is signiifcantly lower than the control group (P0.05);实验组治疗后心率,显著低于对照组(P<0.05);实验组治疗后Pr间期,显著高于对照组(P<0.05)。结论恶性室性心律失常采用静脉植入埋藏式心脏复律除颤器治疗效果理想,值得推广应用。

  8. Monitoring device acceptance in implantable cardioverter defibrillator patients using the Florida Patient Acceptance Survey

    DEFF Research Database (Denmark)

    Versteeg, Henneke; Starrenburg, Annemieke; Denollet, Johan;

    2012-01-01

    Patient device acceptance might be essential in identifying patients at risk for adverse patient-reported outcomes following implantation of an implantable cardioverter defibrillator (ICD). We examined the validity and reliability of the Florida Patient Acceptance Scale (FPAS) and identified corr...

  9. Gender disparities in anxiety and quality of life in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; van den Broek, Krista C; Theuns, Dominic A M J

    2011-01-01

    A paucity of studies in implantable cardioverter-defibrillator (ICD) patients has examined gender disparities in patient-reported outcomes, such as anxiety and quality of life (QoL). We investigated (i) gender disparities in anxiety and QoL and (ii) the magnitude of the effect of gender vs. New...

  10. Undertreatment of anxiety and depression in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Kupper, Nina; Theuns, Dominic A M J

    2012-01-01

    Twenty-five to 33% of patients with an implantable cardioverter-defibrillator (ICD) experience anxiety and depression, but it is not known whether their symptoms are adequately treated. We investigated (a) whether patients with clinically relevant symptoms of distress received appropriate treatment...

  11. SUDDEN CARDIAC DEATH AND THE USE OF IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS IN PEDIATRIC-PATIENTS

    NARCIS (Netherlands)

    SILKA, MJ; KRON, J; DUNNIGAN, A; DICK, M; BINKBOELKENS, M; ERICKSON, CC; JEDEIKIN, R; WETZEL, GT; VANHARE, GF; CAMPBELL, R; WALSH, E; SAUL, JP; SCHAFFER, MS; KARPAWICH, P; VOGEL, RL; BENSON, DW; DEAL, B; SCAGLIOTTI, D; STERBA, R; HORDOF, AJ; KRONGRAD, E; KANTER, RJ; EPSTEIN, M; COHEN, M; BEDER, S; HAMILTON, R; FOURNIER, A; HUBBARD, J; CHRISTIANSEN, JL; JENNINGS, J; VILLAFANE, J; PORTER, CBJ; CASE, C; GILLETTE, PC; BELAND, M; KUGLER, JD; OCONNOR, BK; ALLENDER, H; HERNDON, SP; SMITH, RT; BURTON, D; KURER, CC; BYRUM, C; GUAM, WE; FRIEDMAN, R; PERRY, JC; SCOTT, W; MEHTA, AV; PICKHOFF, AS; FISH, F; YEAGER, S; KAWABORI, [No Value; TRIPPLE, M; ROSENFELD, LE

    1993-01-01

    Background. During the past decade. the implantable cardioverter-defibrillator (ICD) has emerged as the primary therapeutic option for survivors of sudden cardiac death (SCD). Investigation of the clinical efficacy of these devices has primarily assessed outcome in adults with coronary artery diseas

  12. Relation between emotional distress and heart rate variability in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Pedersen, Susanne S.; Theuns, Dominic A M J;

    2014-01-01

    We investigated the relationship between Type D personality, depression, and anxiety, and heart rate variability (HRV) in 64 patients with an implantable cardioverter-defibrillator (ICD). HRV was obtained via 24-h Holter monitoring, and 24-h, 30-min daytime rest and 30-min nighttime sleep HRV were...

  13. Cost-Effectiveness of Adding Cardiac Resynchronization Therapy to an Implantable Cardioverter-Defibrillator Among Patients With Mild Heart Failure

    DEFF Research Database (Denmark)

    Woo, Christopher Y; Strandberg, Erika J; Schmiegelow, Michelle D;

    2015-01-01

    BACKGROUND: Cardiac resynchronization therapy (CRT) reduces mortality and heart failure hospitalizations in patients with mild heart failure. OBJECTIVE: To estimate the cost-effectiveness of adding CRT to an implantable cardioverter-defibrillator (CRT-D) compared with implantable cardioverter......-defibrillator (ICD) alone among patients with left ventricular systolic dysfunction, prolonged intraventricular conduction, and mild heart failure. DESIGN: Markov decision model. DATA SOURCES: Clinical trials, clinical registries, claims data from Centers for Medicare & Medicaid Services, and Centers for Disease...

  14. Inappropriate implantable cardioverter defibrillator shock from a transcutaneous muscle stimulation device therapy.

    Science.gov (United States)

    Siu, Chung-Wah; Tse, Hung-Fat; Lau, Chu-Pak

    2005-06-01

    Inappropriate shock from implantable cardioverter defibrillator (ICD) may result from external electromagnetic interference (EMI), especially for unipolar ventricle sensing. Previous case reports and small in-vitro safety study suggested that endocardial bipolar lead system may be immune from EMI resulting from transcutaneous electrical neuromuscle stimulation (TENS) therapy. This report presents an unusual case of inappropriate discharge in a patient with ICD of endocardial bipolar lead system, receiving TENS from a commercially available device.

  15. Rationale and design of the PRAETORIAN trial: A Prospective, RAndomizEd comparison of subcuTaneOus and tRansvenous ImplANtable cardioverter- defibrillator therapy

    NARCIS (Netherlands)

    L.R.A. Olde Nordkamp (Louise R.A.); R.E. Knops (Reinoud); G.H. Bardy (Gust); Y. Blaauw (Yuri); L. Boersma (Lucas); J.S. Bos (Johannes); P.P.H.M. Delnoy (Peter Paul); P.F.H.M. van Pascal; A.H.G. Driessen (Antoine); J.R. de Groot (Joris); J.P.R. Herrman; L.J.L.M. Jordaens (Luc); K.M. Kooiman (Kirsten); A.H. Maass (Alexander); M. Meine (Mathias); Y. Mizusawa (Yuka); S.G. Molhoek (Sander); J. van Opstal (Jurjen); J.G.P. Tijssen (Jan); A.A.M. Wilde (Arthur)

    2012-01-01

    textabstractBackground: Implantable cardioverter-defibrillators (ICDs) are widely used to prevent fatal outcomes associated with life-threatening arrhythmic episodes in a variety of cardiac diseases. These ICDs rely on transvenous leads for cardiac sensing and defibrillation. A new entirely subcutan

  16. Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients - Results from the PREPARE (Primary Prevention Parameters Evaluation) study

    NARCIS (Netherlands)

    Wilkoff, Bruce L.; Williamson, Brian D.; Stern, Richard S.; Moore, Stephen L.; Lu, Fei; Lee, Sung W.; Birgersdotter-Green, Ulrika M.; Wathen, Mark S.; Van Gelder, Isabelle C.; Heubner, Brooke M.; Brown, Mark L.; Holloman, Keith K.

    2008-01-01

    Objectives Our purpose was to demonstrate that strategically chosen implantable cardioverter-defibrillator (ICD) ventricular tachycardia (VT) or ventricular fibrillation (VF) detection and therapy parameters can reduce the combined incidence of device-delivered shocks, arrhythmic syncope, and untrea

  17. Type D personality is associated with increased anxiety and depressive symptoms in patients with an implantable cardioverter defibrillator and their partners

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van Domburg, Ron T; Theuns, Dominic A M J;

    2014-01-01

    We investigated the prevalence of anxiety and depressive symptoms in patients with an implantable cardioverter defibrillator (ICD) and their partners, and the role of personality factors and social support as determinants of distress.......We investigated the prevalence of anxiety and depressive symptoms in patients with an implantable cardioverter defibrillator (ICD) and their partners, and the role of personality factors and social support as determinants of distress....

  18. Rationale and design of the PRAETORIAN trial: A Prospective, RAndomizEd comparison of subcuTaneOus and tRansvenous ImplANtable cardioverter- defibrillator therapy

    OpenAIRE

    Olde Nordkamp, Louise R.A.; Knops, Reinoud; Bardy, Gust; Blaauw, Yuri; Boersma, Lucas; Bos, Johannes; Delnoy, Peter Paul; Pascal, P.F.H.M.; Driessen, Antoine; Groot, Joris; Herrman, J.P.R.; Jordaens, Luc; Kooiman, Kirsten; Maass, Alexander; Meine, Mathias

    2012-01-01

    textabstractBackground: Implantable cardioverter-defibrillators (ICDs) are widely used to prevent fatal outcomes associated with life-threatening arrhythmic episodes in a variety of cardiac diseases. These ICDs rely on transvenous leads for cardiac sensing and defibrillation. A new entirely subcutaneous ICD overcomes problems associated with transvenous leads. However, the role of the subcutaneous ICD as an adjunctive or primary therapy in patients at risk for sudden cardiac death is unclear....

  19. Spinal cord stimulation for refractory angina in patients implanted with cardioverter defibrillators: five case reports

    DEFF Research Database (Denmark)

    Enggaard, Thomas P; Andersen, Claus; Scherer, Christian

    2010-01-01

    successful long-term treatment with SCS in five patients implanted with cardioverter defibrillators. The combined treatments with ICD and thoracic epidural electrical stimulation were used in five patients with refractory angina pectoris. During the procedure of the implantation, testing with the maximal...... tolerable level of stimulation was carried out to exclude inference with the ICD. The following treatment with SCS has in all cases been successful, with significant pain relief and improved quality of life. There were no incidences of inappropriate defibrillator shocks. Spinal cord stimulation...

  20. The wearable cardioverter-defibrillator: current technology and evolving indications.

    Science.gov (United States)

    Reek, Sven; Burri, Haran; Roberts, Paul R; Perings, Christian; Epstein, Andrew E; Klein, Helmut U

    2016-10-04

    The wearable cardioverter-defibrillator has been available for over a decade and now is frequently prescribed for patients deemed at high arrhythmic risk in whom the underlying pathology is potentially reversible or who are awaiting an implantable cardioverter-defibrillator. The use of the wearable cardioverter-defibrillator is included in the new 2015 ESC guidelines for the management of ventricular arrhythmias and prevention of sudden cardiac death. The present review provides insight into the current technology and an overview of this approach.

  1. Rationale and design of the PRAETORIAN trial : A Prospective, RAndomizEd comparison of subcuTaneOus and tRansvenous ImplANtable cardioverter-defibrillator therapy

    NARCIS (Netherlands)

    Nordkamp, Louise R. A. Olde; Knops, Reinoud E.; Bardy, Gust H.; Blaauw, Yuri; Boersma, Lucas V. A.; Bos, Johannes S.; Delnoy, Peter Paul H. M.; van Dessel, Pascal F. H. M.; Driessen, Antoine H. G.; de Groot, Joris R.; Herrman, Jean Paul R.; Jordaens, Luc J. L. M.; Kooiman, Kirsten M.; Maass, Alexander H.; Meine, Mathias; Mizusawa, Yuka; Molhoek, Sander G.; van Opstal, Jurjen; Tijssen, Jan G. P.; Wilde, Arthur A. M.

    2012-01-01

    Background Implantable cardioverter-defibrillators (ICDs) are widely used to prevent fatal outcomes associated with life-threatening arrhythmic episodes in a variety of cardiac diseases. These ICDs rely on transvenous leads for cardiac sensing and defibrillation. A new entirely subcutaneous ICD over

  2. The National Survey of Cardiac Pacemakers and Cardioverter Defibrillators

    Directory of Open Access Journals (Sweden)

    Gholamrerza Shafieian

    2006-07-01

    Full Text Available Background: Permanent pacemakers provide effective relief of symptoms and are life-saving in patients with symptomatic heart block. Implantable cardioverter defibrillators (ICD are also increasingly recognized as life-saving tools in various groups of patients with malignant ventricular tachyarrhythmias. Methods: As part of the “world survey on pacemaker and ICD implantations”, a survey of all device implantations in Iran during the year 2001 was performed. Data was collected and cross-checked through three sources i.e. direct contact with implanting physicians, pacemaker companies and the governmental pacemaker distributing body.Results: During the year studied, 1635 patients received permanent pacemakers. 88% were new implants at an estimated rate of 24 per million population. The mean age of patients was 65 years and 56.2% were male. 40 cardiologists and 19 surgeons implanted the pacemakers at 27 centers throughout the country. Complete heart block was consistently the most common indication at all centers (mean 56.1%, sick sinus syndrome being the next most common one (mean 20.8%. 69% of the pacemakers were single chamber pacemakers. Transvenous insertion of bipolar steroid-eluting passive fixation leads was the predominant practice at most centers. A total of 60 ICDs were implanted at 7 centers by 9 cardiologists. 45% of ICD implants were dual chamber devices.Conclusion: The survey is the only one available right now and provides useful information about the prevailing pacemaker and defibrillator implantation practice in Iran. Future surveys would be facilitated if a standardized implant registry such as that used in Europe were established in this country.

  3. Dental management of a patient fitted with subcutaneous Implantable Cardioverter Defibrillator device and concomitant warfarin treatment.

    Science.gov (United States)

    Shah, Altaf Hussain; Khalil, Hesham Saleh; Kola, Mohammed Zaheer

    2015-07-01

    Automated Implantable Cardioverter Defibrillators (AICD), simply known as an Implantable Cardioverter Defibrillator (ICD), has been used in patients for more than 30 years. An Implantable Cardioverter Defibrillator (ICD) is a small battery-powered electrical impulse generator that is implanted in patients who are at a risk of sudden cardiac death due to ventricular fibrillation, ventricular tachycardia or any such related event. Typically, patients with these types of occurrences are on anticoagulant therapy. The desired International Normalized Ratio (INR) for these patients is in the range of 2-3 to prevent any subsequent cardiac event. These patients possess a challenge to the dentist in many ways, especially during oral surgical procedures, and these challenges include risk of sudden death, control of post-operative bleeding and pain. This article presents the dental management of a 60 year-old person with an ICD and concomitant anticoagulant therapy. The patient was on multiple medications and was treated for a grossly neglected mouth with multiple carious root stumps. This case report outlines the important issues in managing patients fitted with an ICD device and at a risk of sudden cardiac death.

  4. The use of guideline recommended beta-blocker therapy in primary prevention implantable cardioverter defibrillator patients

    DEFF Research Database (Denmark)

    Ruwald, Anne-Christine; Gislason, Gunnar Hilmar; Vinther, Michael

    2017-01-01

    Aims: We aimed to examine the use of guideline recommended beta-blocker therapy prior to and after primary prevention implantable cardioverter defibrillator (ICD) implantation in a 'real-life' setting. Methods and results: From the Danish Pacemaker and ICD Registry we identified all 1st-time prim......Aims: We aimed to examine the use of guideline recommended beta-blocker therapy prior to and after primary prevention implantable cardioverter defibrillator (ICD) implantation in a 'real-life' setting. Methods and results: From the Danish Pacemaker and ICD Registry we identified all 1st......-time primary prevention ICD and cardiac resynchronization therapy defibrillator (CRT-D) implantations in Denmark from 2007-12 (n = 2935). Use of beta-blocker, type and dose was acquired through the Danish Prescription Registry. According to guideline recommendations, we defined target daily doses as ≥50 mg...... carvedilol and ≥200 mg metoprolol. Prior to implantation 2427 of 2935 (83%) patients received beta-blocker therapy, with 2166 patients (89%) having initiated treatment 3 months or more prior to implantation. The majority of patients was prescribed carvedilol (52%) or metoprolol (41%). Patients on carvedilol...

  5. Attitudes towards implantable cardioverter-defibrillator therapy: a national survey in Danish health-care professionals

    DEFF Research Database (Denmark)

    Johansen, Jens B; Mortensen, Peter T; Videbæk, Regitze

    2011-01-01

    Aims The aim of this study was to examine health-care professionals attitudes towards implantable cardioverter-defibrillator (ICD) therapy and issues discussed with patients. Methods and results Survey of 209 health-care professionals providing specialized treatment and care of ICD patients......-physicians. Physicians were less likely to believe that their personal attitude towards ICD treatment has no influence on how they deal professionally with patients (27.8 vs. 43.6%; P = 0.04). Physicians and non-physicians were equally positive towards ICD therapy as primary prophylaxis in ischaemic cardiomyopathy (87...... discussing ICD treatment with candidate patients. At the same time, physicians are more aware that their attitude towards ICD treatment may influence how they deal professionally with patients compared with non-physicians....

  6. Psychological Functioning and Disease-Related Quality of Life in Pediatric Patients With an Implantable Cardioverter Defibrillator

    NARCIS (Netherlands)

    Koopman, H. M.; Vrijmoet-Wiersma, C. M. J.; Langius, J. N. D.; van den Heuvel, F.; Clur, S. A.; Blank, C. A.; Blom, N. A.; ten Harkel, A. D. J.

    2012-01-01

    The objective of this multicenter study was to evaluate psychological functioning and disease-related quality of life (DRQoL) in pediatric patients with an implantable cardioverter defibrillator (ICD) in The Netherlands. Thirty patients were investigated; the mean age was 16.3 years, and the mean du

  7. Morphology discrimination in implantable cardioverter-defibrillators: Consistency of template match percentage during atrial tachyarrhythmias at different heart rates

    NARCIS (Netherlands)

    D.A.M.J. Theuns (Dominic); M. Rivero-Ayerza (Maximo); D. Goedhart (Dick); M. Miltenburg (Max); L.J.L.M. Jordaens (Luc)

    2008-01-01

    textabstractBackground: Morphology discrimination (MD) in implantable cardioverter-defibrillators (ICDs) is based on the comparison of the ventricular electrogram during tachycardia with a stored reference template obtained during baseline rhythm. However, the effect of heart rate on the template ma

  8. Patient-reported outcomes in Danish implantable cardioverter defibrillator patients with a Sprint Fidelis lead advisory notification

    DEFF Research Database (Denmark)

    Pedersen, Susanne S; Versteeg, Henneke; Nielsen, Jens Cosedis;

    2011-01-01

    Few studies have investigated the association between implantable cardioverter defibrillators (ICDs) and lead advisory notifications and patient-reported outcomes (PROs). We examined (i) whether the mode used to inform patients about a device advisory is associated with PROs, and (ii) whether pat...

  9. Shock and patient preimplantation type D personality are associated with poor health status in patients with implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Tekle, Fetene B; Hoogwegt, Madelein T

    2012-01-01

    Implantable cardioverter-defibrillator (ICD) shock is a critical event to patients associated with well-being after implantation, although other factors may play an equally important role. We compared the association of shock and the patient's preimplantation personality with health status, using...

  10. Bilateral Subclavian Vein Occlusion in a SAPHO Syndrome Patient Who Needed an Implantable Cardioverter Defibrillator.

    Science.gov (United States)

    Ishizuka, Masato; Yamamoto, Yuko; Yamada, Shintaro; Maemura, Sonoko; Nakata, Ryo; Motozawa, Yoshihiro; Yamamoto, Keisuke; Takizawa, Masataka; Uozumi, Hiroki; Ikenouchi, Hiroshi

    2016-05-25

    A 79-year-old Asian man was hospitalized because of progressive exertional dyspnea with decreasing left ventricular ejection fraction and frequent non-sustained ventricular tachycardia. Pre-procedure venography for implantable cardioverter defibrillator (ICD) implantation showed occlusion of the bilateral subclavian veins. In consideration of subcutaneous humps in the sterno-clavicular area and palmoplantar pustulosis, we diagnosed him as having synovitis, acne, pustulosis, hyperostosis, osteitis (SAPHO) syndrome and speculated that it induced peri-osteal chronic inflammation in the sterno-clavicular area, resulting in occlusion of the adjacent bilateral subclavian veins. An automatic external defibrillator (AED) was installed in the patient's house and total subcutaneous ICD was considered. Venous thrombosis in SAPHO syndrome is not frequent but has been reported. To the best of our knowledge, this is the first case of bilateral subclavian vein occlusion in a SAPHO syndrome patient who needs ICD implantation.

  11. Arrhythmia detection in single- and dual-chamber implantable cardioverter defibrillators: the more leads, the better?

    Science.gov (United States)

    Francia, Pietro; Balla, Cristina; Uccellini, Arianna; Cappato, Riccardo

    2009-09-01

    The implantable cardioverter defibrillator (ICD) offers life-saving therapies for primary and secondary prevention of sudden cardiac death in high-risk patients. However, ICD detection algorithms consistently misclassify a substantial proportion of supraventricular rhythms, thus carrying the risk for inappropriate therapies. Although single-chamber ICD (Sc-ICD) discrimination tools have been reported to provide high specificity in rejecting sinus tachycardia and atrial fibrillation with a relatively low ventricular rate, accurate recognition of atrial fibrillation with faster ventricular rates, atrial tachycardias, atrial flutter, and some reentrant tachycardias is still an issue. Dual-chamber ICDs (Dc-ICDs) are supposed to overcome specificity issues by enhancing detection algorithms with information derived from the atrial and ventricular timing relationship. The initial promise of Dc-ICDs was to improve detection specificity without compromising sensitivity, and to translate this advantage over Sc-ICDs in a more selective use of aggressive therapies. Despite this solid background, superiority of Dc- over Sc-ICDs has never been convincingly demonstrated. The present review focuses on the efficacy of contemporary ICD arrhythmia discrimination tools and appraises the so far reported evidence supporting the superiority of Dc-ICDs in preventing inappropriate therapies.

  12. Implantable cardioverter defibrillator specific rehabilitation improves health cost outcomes

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Zwisler, Ann-Dorthe; Koch, Mette Bjerrum

    2015-01-01

    ) were randomized (1:1) to comprehensive cardiac rehabilitation or usual care. Outcomes were measured by implantable cardioverter defibrillator therapy history from patient records and national register follow-up on mortality, hospital admissions and costs. RESULTS: No significant differences were found...... of the rehabilitation group for exercise capacity, general and mental health. The aim of this paper is to explore the long-term health effects and cost implications associated with the rehabilitation programme; more specifically, (i) to compare implantable cardioverter defibrillator therapy history and mortality...... between rehabilitation and usual care groups; (ii) to examine the difference between rehabilitation and usual care groups in terms of time to first admission; and (iii) to determine attributable direct costs. METHODS: Patients with first-time implantable cardioverter defibrillator implantation (n = 196...

  13. Single lead catheter of implantable cardioverter-defibrillator with floating atrial sensing dipole implanted via persistent left superior vena cava.

    Science.gov (United States)

    Malagù, Michele; Toselli, Tiziano; Bertini, Matteo

    2016-04-26

    Persistent left superior vena cava (LSVC) is a congenital anomaly with 0.3%-1% prevalence in the general population. It is usually asymptomatic but in case of transvenous lead positioning, i.e., for pacemaker or implantable cardioverter defibrillator (ICD), may be a cause for significant complications or unsuccessful implantation. Single lead ICD with atrial sensing dipole (ICD DX) is a safe and functional technology in patients without congenital abnormalities. We provide a review of the literature and a case report of successful implantation of an ICD DX in a patient with LSVC and its efficacy in treating ventricular arrhythmias.

  14. Pacemakers and implantable cardioverter defibrillators - general and anesthetic considerations

    Directory of Open Access Journals (Sweden)

    Amy G. Rapsang

    2014-06-01

    Full Text Available A pacemaking system consists of an impulse generator and lead or leads to carry the electrical impulse to the patient's heart. Pacemaker and implantable cardioverter defibrillator codes were made to describe the type of pacemaker or implantable cardioverter defibrillator implanted. Indications for pacing and implantable cardioverter defibrillator implantation were given by the American College of Cardiologists. Certain pacemakers have magnet-operated reed switches incorporated; however, magnet application can have serious adverse effects; hence, devices should be considered programmable unless known otherwise. When a device patient undergoes any procedure (with or without anesthesia, special precautions have to be observed including a focused history/physical examination, interrogation of pacemaker before and after the procedure, emergency drugs/temporary pacing and defibrillation, reprogramming of pacemaker and disabling certain pacemaker functions if required, monitoring of electrolyte and metabolic disturbance and avoiding certain drugs and equipments that can interfere with pacemaker function. If unanticipated device interactions are found, consider discontinuation of the procedure until the source of interference can be eliminated or managed and all corrective measures should be taken to ensure proper pacemaker function should be done. Post procedure, the cardiac rate and rhythm should be monitored continuously and emergency drugs and equipments should be kept ready and consultation with a cardiologist or a pacemaker-implantable cardioverter defibrillator service may be necessary.

  15. Gender disparities in psychological distress and quality of life among patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Brouwers, Corline; van den Broek, Krista C; Denollet, Johan

    2011-01-01

    disparities in psychological distress and QoL in ICD patients by means of a systematic review, and (2) provide recommendations for future research and clinical implications. A systematic search of the literature identified 18 studies with a sample size ≥ 100 that examined gender disparities in anxiety......A subset of patients with an implantable cardioverter defibrillator (ICD) reports psychological distress and poor quality of life (QoL). Gender is one of the factors that has been proposed to explain individual differences in these outcomes. In this viewpoint, we (1) review the evidence for gender....../depression and QoL in ICD patients (mean prevalence of women = 21%; mean age = 62 years). Our review shows that there is insufficient evidence to conclude that gender per se is a major autonomous predictor for disparities in psychological distress and QoL in ICD patients. Women had a higher prevalence of anxiety...

  16. Epileptic seizure in a patient with an implantable cardioverter-defibrillator: Quo vadis right ventricular lead?

    Science.gov (United States)

    Wedekind, Horst; Rozhnev, Andrey; Kleine-Katthöfer, Peter; Kranig, Wolfgang

    2016-03-01

    The case of a 77-year-old man admitted for suspected epileptic seizure is reported. Patient history showed implantation of a single-chamber implantable cardioverter-defibrillator (ICD) after cardiac arrest in 2007 with replacement in 2012 due to battery depletion; the patient reported no previous syncope, unconsciousness or seizures. Interrogation records of the ICD showed five ventricular tachyarrhythmia episodes that corresponded to the "seizure". Further examination revealed incorrect position of the RV-lead. Diagnosis was a provoked epileptic seizure due to undersensing of ventricular tachycardia because of improper ICD lead implantation in the coronary sinus. Treatment consisted of implantation of a new device with an additional ICD lead into the right ventricle.

  17. Shock as a determinant of poor patient-centered outcomes in implantable cardioverter defibrillator patients

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Van Den Broek, Krista C; Van Den Berg, Martha

    2010-01-01

    -PATCH, CIDS, AVID, AMIOVIRT, SCD-HeFT, MADIT-II, and DEFINITE), evidence for an association between ICD shocks and quality of life is mixed, with some indication that the influence of shocks may depend largely on the interval between shocks and assessment of quality of life. In order to improve the clinical......The medical benefits of the implantable cardioverter defibrillator (ICD) are well established, but ICD shocks are known to influence patient-centered outcomes. In this viewpoint, we examine the strength of the evidence as found in primary and secondary prevention trials that used quality of life...... of life may not be as straightforward as previously assumed. Given that programming of the ICD is changing, leading to fewer shocks and improved quality of life, it may be timely to also examine the influence of other determinants (e.g., heart failure progression and the patient's psychological profile...

  18. Changes in psychosocial distress in outpatients with heart failure with implantable cardioverter defibrillators.

    Science.gov (United States)

    Thomas, Sue A; Friedmann, Erika; Gottlieb, Stephen S; Liu, Fang; Morton, Patricia G; Chapa, Deborah W; Lee, Hyeon-Joo; Nahm, Eun-Shim

    2009-01-01

    Patients given implantable cardioverter defibrillators (ICDs) after arrhythmic events or sudden cardiac arrest (SCA) experience psychosocial distress. ICDs now are inserted for the primary prevention of SCA in patients with heart failure; the psychosocial impact of ICDs on patients with heart failure is unknown. Changes in psychosocial status in these ICD recipients were examined. ICD recipients (n = 57) completed depression, anxiety, and social support inventories every 6 months for up to 2 years. Initially, 35% of recipients were depressed and 45% of recipients were anxious. In linear mixed models, depression decreased over time overall but increased in those who experienced ICD shocks. Anxiety decreased in New York Heart Association class III ICD recipients but not in class II ICD recipients. Decreases in social support were related to age: the younger the patient the greater the decrease. A significant proportion of ICD recipients were depressed or anxious, or had diminished social support even after 2 years. Investigation of strategies to improve ICD recipients' psychosocial status is warranted.

  19. [Guidelines on the management of implantable cardioverter defibrillators at the end of life].

    Science.gov (United States)

    Datino, T; Rexach, L; Vidán, M T; Alonso, A; Gándara, Á; Ruiz-García, J; Fontecha, B; Martínez-Sellés, M

    2014-01-01

    This article is a joint document of the Spanish Society of Geriatrics and Gerontology, the Spanish Society of Palliative Care and the Section of Geriatric Cardiology of the Spanish Society of Cardiology. Its aim is to address the huge gap that exists in Spain with regard to the management of implantable cardioverter defibrillators (ICDs) in the final stages of life. It is increasingly common to find patients carrying these devices that are in the terminal stage of an advanced disease. This occurs in patients with advanced heart disease and subsequent heart failure refractory to treatment but also in a patient with an ICD who develops cancer disease, organ failure or other neurodegenerative diseases with poor short-term prognosis. The vast majority of these patients are over 65, so the paper focuses particularly on the elderly who are in this situation, but the decision-making process is similar in younger patients with ICDs who are in the final phase of their life.

  20. A Comparison of the Quality of Life of Patients With an Entirely Subcutaneous Implantable Defibrillator System Versus a Transvenous System (from the EFFORTLESS S-ICD Quality of Life Substudy)

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Mastenbroek, Mirjam H; Carter, Nathan;

    2016-01-01

    The first clinical results from the Evaluation of Factors Impacting Clinical Outcome and Cost Effectiveness of the subcutaneous implantable cardioverter defibrillator (EFFORTLESS S-ICD) Registry on the entirely S-ICD system are promising, but the impact of the S-ICD system on patients' quality of...

  1. Frequent Home Monitoring of ICD Is Effective to Prevent Inappropriate Defibrillator Shock Delivery

    Directory of Open Access Journals (Sweden)

    Paolo Bifulco

    2014-01-01

    Full Text Available Recently, in the context of telemedicine, telemonitoring services are gaining attention. They are offered, for example, to patients with implantable cardioverter defibrillators (ICDs. A major problem associated with ICD therapy is the occurrence of inappropriate shocks which impair patients’ quality of life and may also be arrhythmogenic. The telemonitoring can provide a valid support to intensify followup visits, in order to improve the prevention of inappropriate defibrillator shock, thus enhancing patient safety. Inappropriate shock generally depends on atrial fibrillation, supraventricular tachycardia, and abnormal sensing (such as those caused by electromagnetic interferences. As a practical example, an unusual case of an ICD patient who risked an inappropriate shock while taking a shower is reported. Continuous remote telemonitoring was able to timely warn cardiologist via GSM-SMS, who were able to detect improper sensing examining the intracardiac electrogram via Web. Patient was promptly contacted and warned to not further come in contact with the hydraulic system and any electrical appliance to prevent an inappropriate defibrillator shock. This demonstrates the effectiveness and usefulness of continuous remote telemonitoring in supporting ICD patients.

  2. Impact of carvedilol and metoprolol on inappropriate implantable cardioverter-defibrillator therapy

    DEFF Research Database (Denmark)

    Ruwald, Martin H; Abu-Zeitone, Abeer; Jons, Christian;

    2013-01-01

    The goal of this study was to evaluate the effects of carvedilol and metoprolol on the endpoint of inappropriate implantable cardioverter-defibrillator therapy in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation With Cardiac Resynchronization Therapy) study.......The goal of this study was to evaluate the effects of carvedilol and metoprolol on the endpoint of inappropriate implantable cardioverter-defibrillator therapy in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation With Cardiac Resynchronization Therapy) study....

  3. The effect of intermittent atrial tachyarrhythmia on heart failure or death in cardiac resynchronization therapy with defibrillator versus implantable cardioverter-defibrillator patients

    DEFF Research Database (Denmark)

    Ruwald, Anne-Christine; Pietrasik, Grzegorz; Goldenberg, Ilan;

    2014-01-01

    OBJECTIVES: This study aimed to investigate the effect of both history of intermittent atrial tachyarrhythmias (IAT) and in-trial IAT on the risk of heart failure (HF) or death comparing cardiac resynchronization therapy with defibrillator (CRT-D) to implantable cardioverter-defibrillator (ICD......, respectively, a history of IAT at baseline and time-dependent development of in-trial IAT during follow-up in 1,264 patients with LBBB enrolled in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy) study. RESULTS: The overall beneficial effect of CRT...... of in-trial atrial tachyarrhythmias. (MADIT-CRT: Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy; NCT00180271)....

  4. Lingular pneumonia obscured by implanted cardioverter-defibrillator: Lateral thinking.

    Science.gov (United States)

    Sewell, Laura; Harries, Ivan; Chandrasekaran, Barinathan

    2015-01-01

    A 56-year-old female with an implanted cardioverter-defibrillator was admitted with a short history suggestive of a diagnosis of pneumonia. An AP radiograph did not identify an area of consolidation. A subsequent lateral radiograph highlighted an extensive left-lingular-lobe consolidation that had been obscured by the cardiac device. This case highlights the fact that large devices can obscure significant pathology, and that lateral or cross-sectional imaging may be helpful in reaching a diagnosis.

  5. Lingular pneumonia obscured by implanted cardioverter-defibrillator: Lateral thinking

    OpenAIRE

    Laura Sewell, MD; Ivan Harries, MD; Barinathan Chandrasekaran, MD

    2015-01-01

    A 56-year-old female with an implanted cardioverter-defibrillator was admitted with a short history suggestive of a diagnosis of pneumonia. An AP radiograph did not identify an area of consolidation. A subsequent lateral radiograph highlighted an extensive left-lingular-lobe consolidation that had been obscured by the cardiac device. This case highlights the fact that large devices can obscure significant pathology, and that lateral or cross-sectional imaging may be helpful in reaching a diag...

  6. The distressed (Type D) personality in both patients and partners enhances the risk of emotional distress in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    van den Broek, Krista C; Versteeg, Henneke; Erdman, Ruud A M;

    2011-01-01

    A subgroup of patients with an implantable cardioverter defibrillator (ICD) experiences emotional distress. This may be related to partner factors. We examined the impact of the personality of the partner (i.e., the distressed (Type D) personality) in combination with that of the patient on anxie...

  7. Comorbidity burden is associated with poor psychological well-being and physical health status in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Kupper, Nina; Jordaens, Luc;

    2013-01-01

    Comorbidity burden has been linked to survival in patients with an implantable cardioverter-defibrillator (ICD), but no study has examined the influence on psychological well-being and health status. We examined the relationship between comorbidity burden and anxiety, depression, and health status...

  8. Beta-blocker therapy is not associated with symptoms of depression and anxiety in patients receiving an implantable cardioverter-defibrillator

    NARCIS (Netherlands)

    M.T. Hoogwegt (Madelein); N. Kupper (Nina); D.A.M.J. Theuns (Dominic); L.J.L.M. Jordaens (Luc); S.S. Pedersen (Susanne)

    2012-01-01

    textabstractBeta-blockers are frequently prescribed to implantable cardioverter-defibrillator (ICD) patients. Beta-blocker therapy has been proposed to induce emotional distress such as depression and anxiety, but a paucity of studies has examined the relationship between beta-blockers and distress.

  9. A comparison of the health status and psychological distress of partners of patients with a left ventricular assist device versus an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Brouwers, Corline; Caliskan, Kadir; de Jonge, Nicolaas;

    2014-01-01

    OBJECTIVE: To examine if the caregiving for patients with a left ventricular assist device (LVAD) is related to a poorer health status and more distress compared to patients with an implantable cardioverter defibrillator (ICD). BACKGROUND: Partners distress may influence patient outcomes and is t......OBJECTIVE: To examine if the caregiving for patients with a left ventricular assist device (LVAD) is related to a poorer health status and more distress compared to patients with an implantable cardioverter defibrillator (ICD). BACKGROUND: Partners distress may influence patient outcomes...... (F = 10.71, p = .001) but poorer mental health status (F = 14.82, p compared to ICD partners (F = 3.68, p = .05) at 6 months follow-up, also in adjusted analyses. There was no significant difference between groups on anxiety. CONCLUSION: Caregivers of LVAD...... patients show higher distress levels compared to caregivers of ICD patients. LVAD partners may have a need for support beyond what is offered currently in clinical practice....

  10. Low disease prevalence and inappropriate implantable cardioverter defibrillator shock rate in Brugada syndrome

    DEFF Research Database (Denmark)

    Holst, Anders Gaarsdal; Jensen, Henrik Kjærulf; Eschen, Ole;

    2012-01-01

    of 1.1 definite BrS cases per 100 000 inhabitants. Most definite BrS patients were men (86%) and the median age at diagnosis was 48 years. A total of 35 definite BrS patients (81%) had an implantable cardioverter defibrillator (ICD) implanted and of these 9 (26%) experienced appropriate shocks and 3 (8......%) experienced inappropriate shocks during a median follow-up of 47 months. No patient died or experienced aborted sudden cardiac death during follow-up.ConclusionsWe report the first nationwide study of BrS patients. We found a low incidence of diagnosed definite BrS compared with estimates from ECG surveys....... Follow-up data show a lower rate of inappropriate therapies in ICD carriers than that reported in previous studies....

  11. Spinal cord stimulation for refractory angina in a patient implanted with a cardioverter defibrillator.

    Science.gov (United States)

    Ferrero, Paolo; Grimaldi, Roberto; Massa, Riccardo; Chiribiri, Amedeo; De Luca, Anna; Castellano, Maddalena; Cardano, Paola; Trevi, Gian Paolo

    2007-01-01

    Spinal cord stimulation is currently used to treat refractory angina. Some concerns may arise about the possible interaction concerning the spinal cord stimulator in patients already implanted with a pacemaker or a cardioverter defibrillator. We are going to describe the successful implantation of a spinal cord stimulator in a patient previously implanted with a cardioverter defibrillator.

  12. Beta-blocker therapy is not associated with symptoms of depression and anxiety in patients receiving an implantable cardioverter-defibrillator

    OpenAIRE

    Hoogwegt, Madelein; Kupper, Nina; Theuns, Dominic; Jordaens, Luc; Pedersen, Susanne

    2012-01-01

    textabstractBeta-blockers are frequently prescribed to implantable cardioverter-defibrillator (ICD) patients. Beta-blocker therapy has been proposed to induce emotional distress such as depression and anxiety, but a paucity of studies has examined the relationship between beta-blockers and distress. We investigated the association between beta-blocker therapy, including type and dosage, and symptoms of anxiety and depression in a consecutive cohort of patients receiving an ICD. Between 2003 a...

  13. Beta-blocker therapy is not associated with symptoms of depression and anxiety in patients receiving an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Kupper, Nina; Theuns, Dominic A M J

    2012-01-01

    Beta-blockers are frequently prescribed to implantable cardioverter-defibrillator (ICD) patients. Beta-blocker therapy has been proposed to induce emotional distress such as depression and anxiety, but a paucity of studies has examined the relationship between beta-blockers and distress. We...... investigated the association between beta-blocker therapy, including type and dosage, and symptoms of anxiety and depression in a consecutive cohort of patients receiving an ICD....

  14. Patient perceptions of implantable cardioverter-defibrillator deactivation discussions: A qualitative study

    Directory of Open Access Journals (Sweden)

    Jane MacIver

    2016-04-01

    Full Text Available Background: There is a class I recommendation for implantable cardioverter-defibrillator deactivation discussions to occur between physicians and heart failure patients. Few studies have reported the patient’s perspective on the timing of implantable cardioverter-defibrillator deactivation discussions. Aim: To determine patient awareness, preferences and timing of implantable cardioverter-defibrillator deactivation discussions. Design: Grounded theory was used to collect and analyze interview data from 25 heart failure patients with an implantable cardioverter-defibrillator. Setting and participants: Patients with an implantable cardioverter-defibrillator, from the Heart Function Clinic at University Health Network (Toronto, Canada. Results: The sample (n = 25 was predominately male (76% with an average age of 62 years. Patients identified three stages where they felt implantable cardioverter-defibrillator deactivation should be discussed: (1 prior to implantation, (2 with any significant deterioration but while they were of sound mind to engage in and communicate their preferences and (3 at end of life, where patients wished further review of their previously established preferences and decisions about implantable cardioverter-defibrillator deactivation. Most patients (n = 17, 68% said they would consider deactivation, six (24% were undecided and two (8% were adamant they would never turn it off. Conclusion: The patient preferences identified in this study support the need to include information on implantable cardioverter-defibrillator deactivation at implant, with change in clinical status and within broader discussions about end-of-life treatment preferences. Using this process to help patients determine and communicate their implantable cardioverter-defibrillator deactivation preferences may reduce the number of patients experiencing distressing implantable cardioverter-defibrillator shocks at end of life.

  15. Psychological effects of implantable cardioverter defibrillator shocks. A review of study methods

    Science.gov (United States)

    Manzoni, Gian Mauro; Castelnuovo, Gianluca; Compare, Angelo; Pagnini, Francesco; Essebag, Vidal; Proietti, Riccardo

    2015-01-01

    Background: The implantable cardioverter defibrillator (ICD) saves lives but clinical experience suggests that it may have detrimental effects on mental health. The ICD shock has been largely blamed as the main offender but empirical evidence is not consistent, perhaps because of methodological differences across studies. Objective: To appraise methodologies of studies that assessed the psychological effects of ICD shock and explore associations between methods and results. Data Sources: A comprehensive search of English articles that were published between 1980 and 30 June 2013 was applied to the following electronic databases: PubMed, EMBASE, NHS HTA database, PsycINFO, Sciencedirect and CINAHL. Review Methods: Only studies testing the effects of ICD shock on psychological and quality of life outcomes were included. Data were extracted according to a PICOS pre-defined sheet including methods and study quality indicators. Results: Fifty-four observational studies and six randomized controlled trials met the inclusion criteria. Multiple differences in methods that were used to test the psychological effects of ICD shock were found across them. No significant association with results was observed. Conclusions: Methodological heterogeneity of study methods is too wide and limits any quantitative attempt to account for the mixed findings. Well-built and standardized research is urgently needed. PMID:25698991

  16. Arrhythmia Management in the Elderly-Implanted Cardioverter Defibrillators and Prevention of Sudden Death.

    Science.gov (United States)

    Manian, Usha; Gula, Lorne J

    2016-09-01

    We present an overview of arrhythmia management in elderly patients as it pertains to implantable cardioverter defibrillator (ICD) therapy and prevention of sudden death. Treatment of arrhythmia in elderly patients is fraught with challenges pertaining to goals of care and patient frailty. With an ever increasing amount of technology available, realistic expectations of therapy need to balance quality and quantity of life. The ICD is an important treatment option for selected patients at risk of ventricular arrhythmia and sudden cardiac death. However, the incidence of sudden death as a percentage of all-cause mortality decreases with age. Studies have reported that 20% of elderly patients might die within 1 year of an episode of life-threatening ventricular arrhythmia, but most because of nonarrhythmic causes. This illustrates the 'sudden cardiac death paradox,' with a great proportion of death in elderly patients, even those at risk for ventricular arrhythmias, attributable to medical conditions that cannot be addressed by an ICD. We discuss current practices in ICD therapy in elderly patients, existing evidence from registries and clinical trials, approaches to risk stratification, and important ethical considerations. Although the decision on whether ICD insertion is appropriate in the elderly population remains an area of uncertainty from an evidence-based and ethical perspective, we offer insight on potential clinical and research strategies for this growing population.

  17. Lingular pneumonia obscured by implanted cardioverter-defibrillator: Lateral thinking

    Directory of Open Access Journals (Sweden)

    Laura Sewell, MD

    2015-01-01

    Full Text Available A 56-year-old female with an implanted cardioverter-defibrillator was admitted with a short history suggestive of a diagnosis of pneumonia. An AP radiograph did not identify an area of consolidation. A subsequent lateral radiograph highlighted an extensive left-lingular-lobe consolidation that had been obscured by the cardiac device. This case highlights the fact that large devices can obscure significant pathology, and that lateral or cross-sectional imaging may be helpful in reaching a diagnosis.

  18. Single-coil and dual-coil defibrillator leads and association with clinical outcomes in a complete Danish nationwide ICD cohort

    DEFF Research Database (Denmark)

    Larsen, Jacob M; Hjortshøj, Søren P; Nielsen, Jens C;

    2016-01-01

    BACKGROUND: The best choice of defibrillator lead in patients with routine implantable cardioverter-defibrillator (ICD) is not settled. Traditionally, most physicians prefer dual-coil leads but the use of single-coil leads is increasing. OBJECTIVE: The purpose of this study was to compare clinical...... outcomes in patients with single- and dual-coil leads. METHODS: All 4769 Danish patients 18 years or older with first-time ICD implants from 2007 to 2011 were included from the Danish Pacemaker and ICD Register. Defibrillator leads were 38.9% single-coil leads and 61.1% dual-coil leads. The primary end...... point was all-cause mortality. Secondary end points were lowest successful energy at implant defibrillation testing, first shock failure in spontaneous arrhythmias, structural lead failure, and lead extraction outcomes. RESULTS: Single-coil leads were associated with lower all-cause mortality...

  19. Indications for implantable cardioverter-defibrillators based on evidence and judgment.

    Science.gov (United States)

    Myerburg, Robert J; Reddy, Vivek; Castellanos, Agustin

    2009-08-25

    Implantable cardioverter-defibrillators (ICDs) are generally reliable medical devices that have the potential to add quality years of life for appropriate candidates. Indications for ICDs have emerged from a series of randomized clinical trials, observational data from cohorts of high-risk patients with less common diseases, and expert opinion based on limited data in uncommon disorders. The randomized trials are limited by inadequate stratification designs that resulted from insufficient funding availability. The result was outcomes that led to uneven applications, based in part on post-implant experience of device utilization. In this document, we explore the basis for the features of the evidence available to support ICD use, the role of clinical judgment in circumstances in which data are limited or lacking, and the need for additional research to improve the specificity of indications. Directions for new research initiatives are considered. In addition, a general overview of a clinical research paradigm is presented, in which the research and health care delivery arms of the health care enterprise combine in research design and funding, as the latter bears the impact of the outcomes of the former. Impact estimates during the design of trials, considering reasonable contingencies for outcomes, are suggested as a means of justifying the size, scope, and appropriate costs of studies. If we who are involved in clinical research and health care delivery do not resolve this problem, for both ICDs and other new therapies that appear in the future, society will do it for us.

  20. [The Wearable Cardioverter Defibrillator (WCD) for the prevention of sudden cardiac death -- a single center experience].

    Science.gov (United States)

    Reek, S; Meltendorf, U; Geller, J C; Wollbrück, A; Grund, S; Klein, H U

    2002-12-01

    The Wearable Cardioverter Defibrillator (WCD) is an external defibrillator that automatically detects and treats ventricular tachyarrhythmias without the need for assistance from a bystander while at the same time allowing the patient to ambulate freely. The main components of the system are the defibrillator unit and a chest belt with electrodes for arrhythmia detection and therapy delivery. Between December 1998 and October 2001, 84 patients used the device at our institution. The majority of patients had a history of acute myocardial infarction or coronary artery bypass surgery with an increased risk for sudden cardiac death or were awaiting heart transplantation. During a mean follow-up of 116+/-90 days, 7 episodes of ventricular tachyarrhythmias were detected and terminated successfully by the WCD in 5 patients. In 9720 days, there was one inappropriate shock due to oversensing of electrical noise. Four patients died during follow-up; none of them had a cardiac arrest while wearing the device. Five patients were excluded because of irregularities in device use. An ICD was implanted in 24 patients at the end of the follow-up period. The WCD is effective in detecting and treating ventricular tachyarrhythmias in patients with an intermittently increased risk for sudden cardiac death. Further use of the system in larger patient populations is needed to confirm its safety and cost effectiveness.

  1. Clinical Course After Cardioverter-Defibrillator Implantation: Chagasic Versus Ischemic Patients

    Science.gov (United States)

    Pereira, Francisca Tatiana Moreira; Rocha, Eduardo Arrais; Monteiro, Marcelo de Paula Martins; Lima, Neiberg de Alcantara; Rodrigues Sobrinho, Carlos Roberto Martins; Pires Neto, Roberto da Justa

    2016-01-01

    Background: The outcome of Chagas disease patients after receiving implantable cardioverter defibrillator (ICD) is still controversial. Objective: To compare clinical outcomes after ICD implantation in patients with chronic Chagas cardiomyopathy (CCC) and ischemic heart disease (IHD). Methods: Prospective study of a population of 153 patients receiving ICD (65 with CCC and 88 with IHD). The devices were implanted between 2003 and 2011. Survival rates and event-free survival were compared. Results: The groups were similar regarding sex, functional class and ejection fraction. Ischemic patients were, on average, 10 years older than CCC patients (p < 0.05). Patients with CCC had lower schooling and monthly income than IHD patients (p < 0.05). The number of appropriate therapies was 2.07 higher in CCC patients, who had a greater incidence of appropriate shock (p < 0.05). Annual mortality rate and electrical storm incidence were similar in both groups. There was no sudden death in CCC patients, and only one in IHD patients. Neither survival time (p = 0.720) nor event-free survival (p = 0.143) significantly differed between the groups. Conclusion: CCC doubles the risk of receiving appropriate therapies as compared to IHD, showing the greater complexity of arrhythmias in Chagas patients. PMID:27411097

  2. Implantable cardioverter defibrillator therapy in pediatric and congenital heart disease patients: a single tertiary center experience in Korea

    Directory of Open Access Journals (Sweden)

    Bo Kyung Jin

    2013-03-01

    Full Text Available Purpose: The use of implantable cardioverter defibrillators (ICDs to prevent sudden cardiac death is increasing in children and adolescents. This study investigated the use of ICDs in children with congenital heart disease. Methods: This retrospective study was conducted on the clinical characteristics and effectiveness of ICD implantation at the department of pediatrics of a single tertiary center between 2007 and 2011. Results: Fifteen patients underwent ICD implantation. Their mean age at the time of implantation was 14.5±5.4 years (range, 2 to 22 years. The follow-up duration was 28.9±20.4 months. The cause of ICD implantation was cardiac arrest in 7, sustained ventricular tachycardia in 6, and syncope in 2 patients. The underlying disorders were as follows: ionic channelopathy in 6 patients (long QT type 3 in 4, catecholaminergic polymorphic ventricular tachycardia [CPVT] in 1, and J wave syndrome in 1, cardiomyopathy in 5 patients, and postoperative congenital heart disease in 4 patients. ICD coils were implanted in the pericardial space in 2 children (ages 2 and 6 years. Five patients received appropriate ICD shock therapy, and 2 patients received inappropriate shocks due to supraventricular tachycardia.During follow-up, 2 patients required lead dysfunction-related revision. One patient with CPVT suffered from an ICD storm that was resolved using sympathetic denervation surgery. Conclusion: The overall ICD outcome was acceptable in most pediatric patients. Early diagnosis and timely ICD implantation are recommended for preventing sudden death in high-risk children and patients with congenital heart disease.

  3. T-wave oversensing and inappropriate shocks in implantable cardioverter def ibrillators

    Institute of Scientific and Technical Information of China (English)

    GAO Lei; LU Cai-yi; WANG Shi-wen; XUE Qiao; YAN Wei; ZHOU Sheng-hua; CHEN Rui; LIU Peng; ZHAI Jin-yue

    2010-01-01

    @@ The implantable cardioverter defibrillator (ICD) represents today the treatment and prophylaxis of choice for patients at risk for sustained ventricular tachyarrhythmias.1"6 Accurate sensing of ventricular tachyarrhythmias is a critical aspect of the function of ICD.

  4. Safety Profile of Liver FibroScan in Patients with Cardiac Pacemakers or Implantable Cardioverter-Defibrillators

    Science.gov (United States)

    Pranke, Stephanie; Rashidi, Farid; Nosib, Shravan; Worobetz, Lawrence

    2017-01-01

    Background. Emerging evidence suggests that nonalcoholic fatty liver disease (NAFLD) is associated with coronary artery diseases and arrhythmias. The FibroScan (Echosens, France), a widely available, noninvasive device, is able to detect liver fibrosis and steatosis within this patient population. However, the FibroScan is currently contraindicated in patients with cardiac pacemakers (PM) or implantable cardioverter-defibrillators (ICD). Objective. To determine the safety profile of FibroScan testing in patients with PM or ICD. Methods. Consecutive outpatients undergoing routine device interrogations at a tertiary level teaching hospital underwent simultaneous liver stiffness measurements. PM or ICD performance data, device types, patient demographics, medical history, and previous laboratory and conventional liver imaging results were collected. Results. Analysis of 107 subjects with 33 different types of implanted cardiac devices, from 5 different companies (Medtronic, Sorin, ELA Medical, Boston Scientific, and St. Jude), did not demonstrate any adverse events as defined by abnormal device sensing/pacing or ICD firing. This population included high risk subjects undergoing active pacing (n = 53) and with right pectoral PM placement (n = 1). None of the subjects had any clinical signs of decompensated congestive heart failure or cirrhosis during the exam. Conclusion. TE with FibroScan can be safely performed in patients with PM or ICD.

  5. [Primary prevention of sudden cardiac death through a wearable cardioverter-defibrillator].

    Science.gov (United States)

    Gabrielli, Domenico; Benvenuto, Manuela; Baroni, Matteo; Oliva, Fabrizio; Capucci, Alessandro

    2015-01-01

    Nowadays, the implantable cardioverter-defibrillator is the gold standard for the prevention of sudden cardiac death due to tachyarrhythmias. However, its use is not free from short and long-term risks. In the last years, the wearable cardioverter-defibrillator (WCD) has become a widespread option for patients who need a safe and reversible protection against ventricular tachyarrhythmias. Notwithstanding this, its everyday application is restricted by several limitations, including the risk of inappropriate shocks, the device size and the need for strict compliance of both patients and caregivers. In this review, we report the most relevant literature data on WCD usage along with the main fields of applications and future perspectives.

  6. Association of psychiatric history and type D personality with symptoms of anxiety, depression, and health status prior to ICD implantation

    DEFF Research Database (Denmark)

    Starrenburg, Annemieke H; Kraaier, Karin; Pedersen, Susanne S.;

    2013-01-01

    Personality factors and psychiatric history may help explain individual differences in risk of psychological morbidity and poor health outcomes in patients with an implantable cardioverter defibrillator (ICD).......Personality factors and psychiatric history may help explain individual differences in risk of psychological morbidity and poor health outcomes in patients with an implantable cardioverter defibrillator (ICD)....

  7. Serum-Based Oxylipins Are Associated with Outcomes in Primary Prevention Implantable Cardioverter Defibrillator Patients

    Science.gov (United States)

    Zhang, Yiyi; Guallar, Eliseo; Blasco-Colmenares, Elena; Harms, Amy C.; Vreeken, Rob J.; Hankemeier, Thomas; Tomaselli, Gordon F.; Cheng, Alan

    2016-01-01

    Introduction Individuals with systolic heart failure are at risk of ventricular arrhythmias and all-cause mortality. Little is known regarding the mechanisms underlying these events. We sought to better understand if oxylipins, a diverse class of lipid metabolites derived from the oxidation of polyunsaturated fatty acids, were associated with these outcomes in recipients of primary prevention implantable cardioverter defibrillators (ICDs). Methods Among 479 individuals from the PROSE-ICD study, baseline serum were analyzed and quantitatively profiled for 35 known biologically relevant oxylipin metabolites. Associations with ICD shocks for ventricular arrhythmias and all-cause mortality were evaluated using Cox proportional hazards models. Results Six oxylipins, 17,18-DiHETE (HR = 0.83, 95% CI 0.70 to 0.99 per SD change in oxylipin level), 19,20-DiHDPA (HR = 0.79, 95% CI 0.63 to 0.98), 5,6-DiHETrE (HR = 0.73, 95% CI 0.58 to 0.91), 8,9-DiHETrE (HR = 0.76, 95% CI 0.62 to 0.95), 9,10-DiHOME (HR = 0.81, 95% CI 0.65 to 1.00), and PGF1α (HR = 1.33, 95% CI 1.04 to 1.71) were associated with the risk of appropriate ICD shock after multivariate adjustment for clinical factors. Additionally, 4 oxylipin-to-precursor ratios, 15S-HEPE / FA (20:5-ω3), 17,18-DiHETE / FA (20:5-ω3), 19,20-DiHDPA / FA (20:5-ω3), and 5S-HEPE / FA (20:5-ω3) were positively associated with the risk of all-cause mortality. Conclusion In a prospective cohort of patients with primary prevention ICDs, we identified several novel oxylipin markers that were associated with appropriate shock and mortality using metabolic profiling techniques. These findings may provide new insight into the potential biologic pathways leading to adverse events in this patient population. PMID:27281224

  8. Cognitive-Behavioral Treatment of Posttraumatic Stress in Patients With Implantable Cardioverter Defibrillators: Results From a Randomized Controlled Trial.

    Science.gov (United States)

    Ford, Jessica; Rosman, Lindsey; Wuensch, Karl; Irvine, Jane; Sears, Samuel F

    2016-08-01

    Approximately 20% of patients with implantable cardioverter defibrillators (ICDs) suffer from posttraumatic stress disorder (PTSD) due to a history of cardiac arrest, device implantation, and ICD shock. There has been very little examination of treatment of PTSD symptoms in these patients. This study evaluated the effect of a specific cognitive-behavioral therapy (CBT) intervention for ICD patients with high levels of PTSD symptoms: a manualized program consisting of 8 telephone sessions with a trained counselor, a patient education book, and a stress management procedure on compact disc. Participants were 193 ICD patients, who were randomized to CBT or usual cardiac care (UCC) who completed self-report surveys at the time of recruitment and 6 and 12 months after initial measurement. Previous publication on the primary research evaluation questions reported that the CBT condition resulted in greater improvement on PTSD and depression symptoms than the UCC for the general population of ICD patients, but did not evaluate the effect on those with elevated symptoms of PTSD. The authors conducted secondary analyses of the effect of treatment on high and low PTSD symptom groups based on a cutoff for the Impact of Event Scale-Revised (Weiss & Marmar, 1997). Participants in the CBT group who had high symptoms experienced significantly greater symptom reduction from baseline to 12 months (d = 2.44, p = .021) than the UCC group (d = 1.12). Participants with low symptoms had small reductions regardless of group assignment (d = 0.16, p = .031). ICD-focused CBT was sufficient to produce a large, statistically significant reduction in PTSD symptoms in ICD patients with indications for treatment.

  9. Appropriate evaluation and treatment of heart failure patients after implantable cardioverter-defibrillator discharge: time to go beyond the initial shock.

    Science.gov (United States)

    Mishkin, Joseph D; Saxonhouse, Sherry J; Woo, Gregory W; Burkart, Thomas A; Miles, William M; Conti, Jamie B; Schofield, Richard S; Sears, Samuel F; Aranda, Juan M

    2009-11-24

    Multiple clinical trials support the use of implantable cardioverter-defibrillators (ICDs) for prevention of sudden cardiac death in patients with heart failure (HF). Unfortunately, several complicating issues have arisen from the universal use of ICDs in HF patients. An estimated 20% to 35% of HF patients who receive an ICD for primary prevention will experience an appropriate shock within 1 to 3 years of implant, and one-third of patients will experience an inappropriate shock. An ICD shock is associated with a 2- to 5-fold increase in mortality, with the most common cause being progressive HF. The median time from initial ICD shock to death ranges from 168 to 294 days depending on HF etiology and the appropriateness of the ICD therapy. Despite this prognosis, current guidelines do not provide a clear stepwise approach to managing these high-risk patients. An ICD shock increases HF event risk and should trigger a thorough evaluation to determine the etiology of the shock and guide subsequent therapeutic interventions. Several combinations of pharmacologic and device-based interventions such as adding amiodarone to baseline beta-blocker therapy, adjusting ICD sensitivity, and employing antitachycardia pacing may reduce future appropriate and inappropriate shocks. Aggressive HF surveillance and management is required after an ICD shock, as the risk of sudden cardiac death is transformed to an increased HF event risk.

  10. Longitudinal changes in intracardiac repolarization lability in patients with implantable cardioverter-defibrillator

    Directory of Open Access Journals (Sweden)

    Abhilash eGuduru

    2013-08-01

    Full Text Available Background─While it is known that elevated baseline intracardiac repolarization lability is associated with the risk of fast ventricular tachycardia (FVT /ventricular fibrillation (VF, the effect of its longitudinal changes on the risk of FVT/VF is unknown. Methods and Results─Near-field (NF right ventricular (RV intracardiac electrograms (EGMs were recorded every 3-6 months at rest in 248 patients with structural heart disease (mean age 61.2±13.3; 185[75%] male; 162[65.3%] ischemic cardiomyopathy and implanted cardioverter-defibrillator (ICD or cardiac resynchronization therapy defibrillator (CRT-D [201 (81% primary prevention]. Intracardiac beat-to-beat QT variability index (QTVINF was measured on NF RV EGM. During the first study phase (median 18 months, participants made on average 2.4 visits. Then remote follow-up was continued for an additional median period of 3 years. Average QTVINF did not change during the first year after ICD implantation (-0.342±0.603 at baseline vs. -0.262±0.552 at 6 months vs. -0.334±0.603 at 12 months; however, it decreased thereafter (-0.510±0.603 at 18 months; P=0.042. Adjusted population-averaged GEE model showed that the odds of developing FVT/VF increased by 75% for each 1 unit increase in QTVINF. (OR 1.75 [95%CI 1.05-2.92]; P=0.031. However, individual patient–specific QTVINF trends (increasing, decreasing, flat varied from patient to patient. For a given patient, the odds of developing FVT/VF were not associated with increasing or decreasing QTVINF over time (OR 1.27; [95%CI 0.05–30.10]; P = 0.881.Conclusion─While on average the odds of FVT/VF increased with an increase in QTVINF, patient-specific longitudinal trends in QTVINF did not affect the odds of FVT/VF.

  11. Potential clinical impact of cardiovascular magnetic resonance assessment of ejection fraction on eligibility for cardioverter defibrillator implantation

    Directory of Open Access Journals (Sweden)

    Joshi Subodh B

    2012-10-01

    Full Text Available Abstract Background For the primary prevention of sudden cardiac death, guidelines provide left ventricular ejection fraction (EF criteria for implantable cardioverter defibrillator (ICD placement without specifying the technique by which it should be measured. We sought to investigate the potential impact of performing cardiovascular magnetic resonance (CMR for EF on ICD eligibility. Methods The study population consisted of patients being considered for ICD implantation who were referred for EF assessment by CMR. Patients who underwent CMR within 30 days of echocardiography were included. Echocardiographic EF was determined by Simpson’s biplane method and CMR EF was measured by Simpson’s summation of discs method. Results Fifty-two patients (age 62±15 years, 81% male had a mean EF of 38 ± 14% by echocardiography and 35 ± 14% by CMR. CMR had greater reproducibility than echocardiography for both intra-observer (ICC, 0.98 vs 0.94 and inter-observer comparisons (ICC 0.99 vs 0.93. The limits of agreement comparing CMR and echocardiographic EF were – 16 to +10 percentage points. CMR resulted in 11 of 52 (21% and 5 of 52 (10% of patients being reclassified regarding ICD eligibility at the EF thresholds of 35 and 30% respectively. Among patients with an echocardiographic EF of between 25 and 40%, 9 of 22 (41% were reclassified by CMR at either the 35 or 30% threshold. Echocardiography identified only 1 of the 6 patients with left ventricular thrombus noted incidentally on CMR. Conclusions CMR resulted in 21% of patients being reclassified regarding ICD eligibility when strict EF criteria were used. In addition, CMR detected unexpected left ventricular thrombus in almost 10% of patients. Our findings suggest that the use of CMR for EF assessment may have a substantial impact on management in patients being considered for ICD implantation.

  12. Wrong detection of ventricular fibrillation in an implantable cardioverter defibrillator caused by the movement near the MRI scanner bore.

    Science.gov (United States)

    Mattei, Eugenio; Censi, Federica; Triventi, Michele; Mancini, Matteo; Napolitano, Antonio; Genovese, Elisabetta; Cannata, Vittorio; Falsaperla, Rosaria; Calcagnini, Giovanni

    2015-01-01

    The static magnetic field generated by MRI systems is highly non-homogenous and rapidly decreases when moving away from the bore of the scanner. Consequently, the movement around the MRI scanner is equivalent to an exposure to a time-varying magnetic field at very low frequency (few Hz). For patients with an implanted cardiac stimulators, such as an implantable cardioverter/defibrillator (ICD), the movements inside the MRI environment may thus induce voltages on the loop formed by the leads of the device, with the potential to affect the behavior of the stimulator. In particular, the ICD's detection algorithms may be affected by the induced voltage and may cause inappropriate sensing, arrhythmia detections, and eventually inappropriate ICD therapy.We performed in-vitro measurements on a saline-filled humanshaped phantom (male, 170 cm height), equipped with an MRconditional ICD able to transmit in real-time the detected cardiac activity (electrograms). A biventricular implant was reproduced and the ICD was programmed in standard operating conditions, but with the shock delivery disabled. The electrograms recorded in the atrial, left and right ventricle channels were monitored during rotational movements along the vertical axis, in close proximity of the bore. The phantom was also equipped with an accelerometer and a magnetic field probe to measure the angular velocity and the magnetic field variation during the experiment. Pacing inhibition, inappropriate detection of tachyarrhythmias and of ventricular fibrillation were observed. Pacing inhibition began at an angular velocity of about 7 rad/s, (dB/dt of about 2 T/s). Inappropriate detection of ventricular fibrillation occurred at about 8 rad/s (dB/dt of about 3 T/s). These findings highlight the need for a specific risk assessment of workers with MR-conditional ICDs, which takes into account also effects that are generally not considered relevant for patients, such as the movement around the scanner bore.

  13. A pilot study of a mindfulness based stress reduction program in adolescents with implantable cardioverter defibrillators or pacemakers.

    Science.gov (United States)

    Freedenberg, Vicki A; Thomas, Sue A; Friedmann, Erika

    2015-04-01

    Adolescents with implantable cardioverter defibrillators (ICDs) or pacemakers (PMs) face unique challenges that can cause psychosocial distress. Psychosocial interventions are effective for adults with cardiac devices and could potentially impact adolescents' adjustment to these devices. Mindfulness Based Stress Reduction (MBSR) is a structured psycho-educational program that includes meditation, yoga, and group support and has been studied extensively among adults. This study examined the feasibility of the MBSR program for adolescents with ICDs/PMs, a population previously unexamined in the research literature. The participants completed measures of anxiety and depression (Hospital Anxiety and Depression Scale) and coping (Responses to Stress Questionnaire) at baseline and after the six-session MBSR intervention. Mean age of the cohort (n = 10) was 15 ± 3 years, 6 were male, 6 had a PM, and 4 had an ICD. Feasibility was demonstrated by successful recruitment of 10 participants, 100 % participation and completion. Anxiety decreased significantly following the intervention, with a large effect size, t[9] = 3.67, p MBSR interventions in adolescents with high-risk cardiac diagnoses.

  14. Efficacy of cognitive behavioral therapy in reducing psychiatric symptoms in patients with implantable cardioverter defibrillator: an integrative review.

    Science.gov (United States)

    Maia, A C C O; Braga, A A; Soares-Filho, G; Pereira, V; Nardi, A E; Silva, A C

    2014-04-01

    This article is a systematic review of the available literature on the benefits that cognitive behavioral therapy (CBT) offers patients with implanted cardioverter defibrillators (ICDs) and confirms its effectiveness. After receiving the device, some patients fear that it will malfunction, or they remain in a constant state of tension due to sudden electrical discharges and develop symptoms of anxiety and depression. A search with the key words "anxiety", "depression", "implantable cardioverter", "cognitive behavioral therapy" and "psychotherapy" was carried out. The search was conducted in early January 2013. Sources for the search were ISI Web of Knowledge, PubMed, and PsycINFO. A total of 224 articles were retrieved: 155 from PubMed, 69 from ISI Web of Knowledge. Of these, 16 were written in a foreign language and 47 were duplicates, leaving 161 references for analysis of the abstracts. A total of 19 articles were eliminated after analysis of the abstracts, 13 were eliminated after full-text reading, and 11 articles were selected for the review. The collection of articles for literature review covered studies conducted over a period of 13 years (1998-2011), and, according to methodological design, there were 1 cross-sectional study, 1 prospective observational study, 2 clinical trials, 4 case-control studies, and 3 case studies. The criterion used for selection of the 11 articles was the effectiveness of the intervention of CBT to decrease anxiety and depression in patients with ICD, expressed as a ratio. The research indicated that CBT has been effective in the treatment of ICD patients with depressive and anxiety symptoms. Research also showed that young women represented a risk group, for which further study is needed. Because the number of references on this theme was small, further studies should be carried out.

  15. [Rehabilitation of patients with cardiac pacemakers and implanted cardioverter-defibrillators: recommendations for training, physiotherapeutic procedures and re-employment].

    Science.gov (United States)

    Reibis, R K; Kamke, W; Langheim, E; Völler, H

    2010-04-01

    Rehabilitation of patients with cardiac pacemakers (CP) or implantable cardioverter defibrillators (ICD) comprises secondary prevention of underlying cardiac disease, conditioning training activities and psychological education and includes furthermore the assessment of aggregate function, detection of any device malfunction as well as the return to work efforts. The extent to which the physical activities can be permitted is determined by both cardiopulmonary capacity and the primary arrhythmic indication. Under consideration of upper frequency limit, left ventricular dysfunction and the avoidance of mechanical exposure on device can and leads, an individually designed training programme is acceptable even on a high load level. Likewise, electrotherapeutic procedures due to musculoskeletal pain syndrome are not generally contraindicated, if differentiated limitations are respected. Beside the assessment of aggregate function and, if necessary, parameter optimization, psychologic intervention programs play an important role particularly in ICD-patients and can be utilized as an additive therapeutic module. Personalized recommendations for driving with an ICD are determined by the time interval since idex arrhythmia and the rhythmological risk profile as well as by the motor vehicle class. The return to work rate of CP and ICD patients is resumably influenced by the underlying cardiac disease and to a lesser extend by the implanted device. Except industrial jobs the risk of electromagnetic interference during the working process is low and can be objected by working place analysis including noise field measurement. Thus cardiac of CP and ICD patients should be used to a large extend for the recovery of individual physical and psychological integrity as well as for the organisation of reemployment.

  16. Conservative Management of Skin Fistula Occurring After Internal Cardioverter Defibrillator Replacement

    OpenAIRE

    2012-01-01

    Skin fistula occurring after cardiac electronic device implantation is frequently related to pocket infection and this condition typically requires removal of device and lead(s). We report on a case of skin fistula occurring 3 weeks after internal cardioverter defibrillator replacement. Conservative management consisted of local care along with oral antibiotics without removal of device; this strategy resulted in complete healing and closure of the fistula.

  17. Implantable defibrillator therapy: more than defibrillation...

    NARCIS (Netherlands)

    D.A.M.J. Theuns (Dominic)

    2005-01-01

    textabstractDuring the past 25 years, the implantable cardioverter-defibrillator (ICD) has evolved from the treatment of last resort to the gold standard for patients at high risk for life­threatening ventricular tachyarrhythmias. Patients at high risk include those who survived life-threatening ven

  18. Athletic participation in the young patient with an implantable cardioverter-defibrillator.

    Science.gov (United States)

    Lampert, Rachel; Law, Ian

    2017-01-01

    The decision of whether to allow a young patient with an implantable cardioverter-defibrillator to continue to participate in sports is complex and multi-factorial. The positive physical and psychosocial impact of sports participation must be weighed against the potential adverse events associated with implantable cardioverter-defibrillators. Arrhythmias appear to be more prevalent in athletes and occur more frequently during physical activity or competition/practice, but there is growing evidence that device therapy is effective in athletes across a wide range of competitive sports. Failure of a device to convert a life-threatening arrhythmia, major injury from a shock, and increased lead failure have thus far not been reported in the prospective Implantable Cardioverter-Defibrillator Sports Registry, but follow-up remains relatively short. Thoughtful consideration of disease state, arrhythmia risk, and the potential dangers of device therapy during the desired sports is imperative before allowing participation. Frank discussion with children and families regarding the possibility of shocks during sports, as well as at other times, is imperative. Ongoing and future studies will help guide these decisions.

  19. Gender differences in appropriate shocks and mortality among patients with primary prophylactic implantable cardioverter-defibrillators: Systematic review and meta-analysis

    CERN Document Server

    Conen, David; Röver, Christian; Bergau, Leonard; Muñoz, Pascal; Wijers, Sofieke; Sticherling, Christian; Zabel, Markus; Friede, Tim

    2016-01-01

    BACKGROUND: Some but not all prior studies have shown that women receiving a primary prophylactic implantable cardioverter defibrillator (ICD) have a lower risk of death and appropriate shocks than men. PURPOSE: To evaluate the effect of gender on the risk of appropriate shock, all-cause mortality and inappropriate shock in contemporary studies of patients receiving a primary prophylactic ICD. DATA SOURCE: PubMed, LIVIVO, Cochrane CENTRAL between 2010 and 2016. STUDY SELECTION: Studies providing at least 1 gender-specific risk estimate for the outcomes of interest. DATA EXTRACTION: Abstracts were screened independently for potentially eligible studies for inclusion. Thereby each abstract was reviewed by at least two authors. DATA SYNTHESIS: Out of 680 abstracts retained by our search strategy, 20 studies including 46'657 patients had gender-specific information on at least one of the relevant endpoints. Mean age across the individual studies varied between 58 and 69 years. The proportion of women enrolled ran...

  20. The Medtronic Sprint Fidelis Lead Advisory Notification has no adverse impact on patient reported outcomes in Danish implantable cardioverter defibrillator patients

    DEFF Research Database (Denmark)

    Pedersen, Susanne Møller; Versteeg, Henneke; Nielsen, Jens C.;

    The Medtronic Sprint Fidelis Lead Advisory Notification has no adverse impact on patient reported outcomes in Danish implantable cardioverter defibrillator patients.......The Medtronic Sprint Fidelis Lead Advisory Notification has no adverse impact on patient reported outcomes in Danish implantable cardioverter defibrillator patients....

  1. The Medtronic Sprint Fidelis Lead Advisory Notification Has No Adverse Impact on Patient Reported Outcomes in Danish Implantable Cardioverter Defibrillator Patients

    DEFF Research Database (Denmark)

    Pedersen, Susanne Møller; Versteeg, Henneke; Nielsen, Jens C.;

    The Medtronic Sprint Fidelis Lead Advisory Notification Has No Adverse Impact on Patient Reported Outcomes in Danish Implantable Cardioverter Defibrillator Patients.......The Medtronic Sprint Fidelis Lead Advisory Notification Has No Adverse Impact on Patient Reported Outcomes in Danish Implantable Cardioverter Defibrillator Patients....

  2. Temporal Influence of Heart Failure Hospitalizations Prior to Implantable Cardioverter Defibrillator or Cardiac Resynchronization Therapy With Defibrillator on Subsequent Outcome in Mild Heart Failure Patients (from MADIT-CRT)

    DEFF Research Database (Denmark)

    Lee, Andy Y; Moss, Arthur J; Ruwald, Martin H;

    2015-01-01

    The temporal effect of heart failure (HF) hospitalization occurring at different time periods before implantation has not yet been studied in detail. The aim of the present study was to investigate the potential association between time from last HF hospitalization to device implantation and effe......The temporal effect of heart failure (HF) hospitalization occurring at different time periods before implantation has not yet been studied in detail. The aim of the present study was to investigate the potential association between time from last HF hospitalization to device implantation...... and effects on subsequent outcomes and benefit from cardiac resynchronization therapy with a defibrillator (CRT-D). Multivariate Cox models were used to determine the temporal influence of previous HF hospitalization on the end point of HF or death within all left bundle branch block implantable cardioverter......-defibrillator (ICD) and CRT-D patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT) trial (n = 1,250) and to evaluate the clinical benefit of CRT-D implantation, comparing CRT-D patients with ICD patients within each previous HF hospitalization...

  3. Inappropriate shocks in the subcutaneous ICD

    DEFF Research Database (Denmark)

    Olde Nordkamp, Louise R A; Brouwer, Tom F; Barr, Craig

    2015-01-01

    BACKGROUND: The entirely subcutaneous implantable cardioverter-defibrillator (S-ICD) eliminates the need for transvenous leads, and therefore has the potential to improve lead-longevity and reduce lead-related complications. The S-ICD has a morphology-based sensing algorithm of which inappropriat...

  4. Shock whilst gardening--implantable defibrillators & lawn mowers.

    Science.gov (United States)

    Von Olshausen, G; Lennerz, C; Grebmer, C; Pavaci, H; Kolb, C

    2014-02-01

    Electromagnetic interference with implantable cardioverter defibrillators (ICDs) can cause inappropriate shock delivery or temporary inhibition of ICD functions. We present a case of electromagnetic interference between a lawn mower and an ICD resulting in an inappropriate discharge of the device due to erroneous detection of ventricular fibrillation.

  5. Efficacy of cognitive behavioral therapy in reducing psychiatric symptoms in patients with implantable cardioverter defibrillator: an integrative review

    Directory of Open Access Journals (Sweden)

    A.C.C.O. Maia

    2014-04-01

    Full Text Available This article is a systematic review of the available literature on the benefits that cognitive behavioral therapy (CBT offers patients with implanted cardioverter defibrillators (ICDs and confirms its effectiveness. After receiving the device, some patients fear that it will malfunction, or they remain in a constant state of tension due to sudden electrical discharges and develop symptoms of anxiety and depression. A search with the key words “anxiety”, “depression”, “implantable cardioverter”, “cognitive behavioral therapy” and “psychotherapy” was carried out. The search was conducted in early January 2013. Sources for the search were ISI Web of Knowledge, PubMed, and PsycINFO. A total of 224 articles were retrieved: 155 from PubMed, 69 from ISI Web of Knowledge. Of these, 16 were written in a foreign language and 47 were duplicates, leaving 161 references for analysis of the abstracts. A total of 19 articles were eliminated after analysis of the abstracts, 13 were eliminated after full-text reading, and 11 articles were selected for the review. The collection of articles for literature review covered studies conducted over a period of 13 years (1998-2011, and, according to methodological design, there were 1 cross-sectional study, 1 prospective observational study, 2 clinical trials, 4 case-control studies, and 3 case studies. The criterion used for selection of the 11 articles was the effectiveness of the intervention of CBT to decrease anxiety and depression in patients with ICD, expressed as a ratio. The research indicated that CBT has been effective in the treatment of ICD patients with depressive and anxiety symptoms. Research also showed that young women represented a risk group, for which further study is needed. Because the number of references on this theme was small, further studies should be carried out.

  6. Capsule endoscopy in patients with cardiac pacemakers, implantable cardioverter defibrillators and left heart assist devices.

    Science.gov (United States)

    Bandorski, Dirk; Höltgen, Reinhard; Stunder, Dominik; Keuchel, Martin

    2014-01-01

    According to the recommendations of the US Food and Drug Administration and manufacturers, capsule endoscopy should not be used in patients carrying implanted cardiac devices. For this review we considered studies indexed (until 30.06.2013) in Medline [keywords: capsule endoscopy, small bowel endoscopy, cardiac pacemaker, implantable cardioverter defibrillator, interference, left heart assist device], technical information from Given Imaging and one own publication (not listed in Medline). Several in vitro and in vivo studies included patients with implanted cardiac devices who underwent capsule endoscopy. No clinically relevant interference was noticed. Initial reports on interference with a simulating device were not reproduced. Furthermore technical data of PillCam (Given Imaging) demonstrate that the maximum transmission power is below the permitted limits for cardiac devices. Hence, impairment of cardiac pacemaker, defibrillator or left ventricular heart assist device function by capsule endoscopy is not expected. However, wireless telemetry can cause dysfunction of capsule endoscopy recording. Application of capsule endoscopy is feasible and safe in patients with implanted cardiac devices such as pacemakers, cardioverter defibrillators, and left heart assist devices. Development of new technologies warrants future re-evaluation.

  7. Phantom shocks in patients with implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Moons, Philip; Zwisler, Ann-Dorthe;

    2013-01-01

    of phantom shocks.METHODS AND RESULTS: The design was secondary explorative analyses of data from a randomized controlled trial. One hundred and ninety-six patients with first-time ICD implantation (79% male, mean age 58 years) were randomized (1 : 1) to either combined rehabilitation or a control group...

  8. Venous thromboembolism in patients with implantable cardioverter-defibrillators

    DEFF Research Database (Denmark)

    Pedersen, Susanne Bendesgaard; Hjortshøj, Søren Pihlkjær; Bøtker, Hans Erik;

    2016-01-01

    , overall and according to gender, age, Charlson Comorbidity Index score (no, moderate, or severe comorbidity), prior pacemaker or cardiac resynchronization therapy (CRT-D) implantation, and ICD type (single-chamber, dual-chamber, or CRT-D). We computed the risk of VTE within 3 months and 5 years...

  9. Cardioverter-defibrillator implantation to treat cardiac fibroma-induced ventricular tachycardia in a 70-year-old woman.

    Science.gov (United States)

    Hakim, Fayaz Ahmad; Pandit, Anil; Mookadam, Farouk; Mamby, Sylvia

    2014-06-01

    Benign cardiac fibroma is rarely reported in adults. Its clinical symptoms are related to outflow obstruction or dysrhythmias. We present the case of a 70-year-old woman who had a syncopal episode from ventricular tachycardia caused by cardiac fibroma. Because of unfavorable tumor anatomy, the patient was not a candidate for surgical excision, and she declined orthotopic heart transplantation. To prevent sudden cardiac death, we placed an implantable cardioverter-defibrillator, and the patient remained well throughout the 2-year follow-up period. To our knowledge, this is the first report of implantable cardioverter-defibrillator therapy to treat an adult patient's unresectable cardiac fibroma.

  10. Rationale, design, and baseline characteristics of the DANish randomized, controlled, multicenter study to assess the efficacy of Implantable cardioverter defibrillators in patients with non-ischemic Systolic Heart failure on mortality (DANISH)

    DEFF Research Database (Denmark)

    Thune, Jens Jakob; Pehrson, Steen; Nielsen, Jens Cosedis;

    2016-01-01

    BACKGROUND: The effect of an implantable cardioverter defibrillator (ICD) in patients with symptomatic systolic heart failure (HF) caused by coronary artery disease is well documented. However, the effect of primary prophylactic ICDs in patients with systolic HF not due to coronary artery disease...... by coronary artery disease have been randomized to receive an ICD or not, in addition to contemporary standard therapy. The primary outcome of the trial is time to all-cause death. Follow-up will continue until June 2016 with a median follow-up period of 5 years. Baseline characteristics show that enrolled...... (range, 21-84 years) at baseline, and 28% were women. CONCLUSION: DANISH will provide pertinent information about the effect on all-cause mortality of a primary prophylactic ICD in patients with symptomatic systolic HF not caused by coronary artery disease on contemporary standard therapy including CRT....

  11. Intensity of primary emotions in patients after implantation of an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Stoier, Louise; Pedersen, Preben Ulrich; Berg, Selina Kikkenborg

    2013-01-01

    Background: Experienced emotions can affect the outcome of, and adherence to a cardiac rehabilitation program, and patients coping with an illness. With more awareness of the expressed emotions, health professionals might be better able to understand the reactions of patients and to improve...... the support needed for coping. Living with an Implantable Cardi- overter Defibrillator can lead to anxiety and depression. Focus on the intensity of the primary emotions might be a potential to prevent development of these psychological states. Objectives: The aim of this paper are 1) to describe...... the intensity of primary emotions in patients after implantation of an Implantable Cardioverter Defibrillator and 2) to compare them with both the intensity of primary emotions in patients with a recent Myocardial Infarction and with a healthy population. Method: The intensity of primary emotions in patients...

  12. Worldwide experience with a totally subcutaneous implantable defibrillator: Early results from the EFFORTLESS S-ICD registry

    NARCIS (Netherlands)

    P.D. Lambiase (Pier); C.S. Barr (Craig); D.A.M.J. Theuns (Dominic); R.E. Knops (Reinoud); P. Neuzil (Petr); J.B. Johansen (Jens); A.M. Hood (Margaret); S.S. Pedersen (Susanne); S. Kääb (Stefan); F.D. Murgatroyd (Francis); H.L. Reeve (Helen); N. Carter (Nathan); L. Boersma (Lucas)

    2014-01-01

    textabstractAims The totally subcutaneous implantable-defibrillator (S-ICD) is a new alternative to the conventional transvenous ICD system to minimize intravascular lead complications. There are limited data describing the long-term performance of the S-ICD. This paper presents the first large inte

  13. Nurse- and peer-led self-management programme for patients with an implantable cardioverter defibrillator; a feasibility study

    Directory of Open Access Journals (Sweden)

    van Eijk Jacques

    2007-09-01

    Full Text Available Abstract Background The prevalence of cardiovascular disease is increasing. Improved treatment options increase survival after an acute myocardial infarction or sudden cardiac arrest, although patients often have difficulty adjusting and regaining control in daily life. In particular, patients who received an implantable cardioverter defibrillator (ICD experience physical and psychological problems. Interventions to enhance perceived control and acceptance of the device are therefore necessary. This paper describes a small-scale study to explore the feasibility and the possible benefits of a structured nurse- and peer-led self-management programme ('Chronic Disease Self-Management Program' – CDSMP among ICD patients. Methods Ten male ICD patients (mean age = 65.5 years participated in a group programme, consisting of six sessions, led by a team consisting of a nurse specialist and a patient with cardiovascular disease. Programme feasibility was evaluated among patients and leaders by measuring performance of the intervention according to protocol, attendance and adherence of the participating ICD patients, and patients' and leaders' opinions about the programme. In addition, before and directly after attending the intervention, programme benefits (e.g. perceived control, symptoms of anxiety and depression, and quality of life were assessed. Results The programme was conducted largely according to protocol. Eight patients attended at least four sessions, and adherence ranged from good to very good. On average, the patients reported to have benefited very much from the programme, which they gave an overall report mark of 8.4. The leaders considered the programme feasible as well. Furthermore, improvements were identified for general self-efficacy expectancies, symptoms of anxiety, physical functioning, social functioning, role limitations due to physical problems, and pain. Conclusion This study suggests that a self-management programme led by a

  14. Prophylactic use of implantable cardioverter-defibrillators in the elderly population

    Institute of Scientific and Technical Information of China (English)

    Yuchuan LIU; Hue-Teh Shih

    2005-01-01

    @@ Introduction Sudden cardiac death (SCD) accounts for approximately 300,000 deaths each year in the United States. Ventricular fibrillation, as the initial event, had been reported in 65%-85% of these patients.1 An implantable cardioverterdefibrillator (ICD) is the single most effective life saving device to date. The advances in medicine and technology have led to wide spread utilization of defibrillators in developed countries.

  15. Association of Psychiatric History and Type D Personality with Symptoms of Anxiety, Depression, and Health Status Prior to ICD Implantation

    NARCIS (Netherlands)

    Starrenburg, Annemieke H.; Kraaier, Karin; Pedersen, Susanne S.; Hout, Moniek; Scholten, Marcoen; Palen, van der Job

    2013-01-01

    BACKGROUND: Personality factors and psychiatric history may help explain individual differences in risk of psychological morbidity and poor health outcomes in patients with an implantable cardioverter defibrillator (ICD). PURPOSE: We examined associations between previous anxiety and depressive diso

  16. Successful use of wearable cardioverter defibrillator in a patient with dextrocardia and persistent left superior vena cava.

    Science.gov (United States)

    Wan, Chingping; Oren, Jess W; Szymkiewicz, Steven J

    2013-09-01

    Congenital disorders, such as dextrocardia and persistent left superior vena cava, are rare. However, their presence is often associated with other cardiac anomalies, and may lead to lethal ventricular tachyarrhythmias, which result in sudden cardiac death. Treating patients with these disorders can present a challenge to clinicians, as it may cause technical difficulties during interventional procedures, and more often, altered defibrillation techniques in a setting of prehospital sudden cardiac arrest. This report describes the first case of successful defibrillation therapy delivered by the wearable cardioverter defibrillator to a patient with dextrocardia and persistent left superior vena cava during a ventricular tachycardia arrest.

  17. Conscious sedation as an anaesthetic technique in patients undergoing nonthoracotomy placement of automatic implantable cardioverter defibrillator : an initial experience.

    Directory of Open Access Journals (Sweden)

    Singh V

    2004-01-01

    Full Text Available Six adult patients with life threatening recurrent ventricular arrhythmias who underwent non- thoracotomy placement of automatic implantable cardioverter defibrillator under conscious sedation are reported. Our clinical experience, patient satisfaction, recovery profile, complications and cardiologist perception about the technique of conscious sedation is presented and discussed.

  18. Economical aspect of PET/CT-guided diagnosis of suspected infective endocarditis in a patient with implantable cardioverter-defibrillator.

    Science.gov (United States)

    Farkowski, Michal M; Milkowski, Maciej; Dziuk, Mirosław; Pytkowski, Mariusz; Marciniak, Marta; Kraska, Alicja; Szwed, Hanna; Sterlinski, Maciej

    2014-01-01

    We present a case report of potential reduction of hospitalization costs due to utilization of PET/CT in a diagnostic work-up of a patient with an implantable cardioverter-defibrillator and suspicion of infective endocarditis. The PET/CT scan would have shorten hospital stay, prevented clinical complications and reduced the cost of hospitalization by 45%.

  19. A review of economic evaluation models for cardiac resynchronization therapy with implantable cardioverter defibrillators in patients with heart failure

    NARCIS (Netherlands)

    Tomini, F.; van Asselt, A. D.

    2012-01-01

    OBJECTIVES: Cardiac resynchronization therapy with biventricular pacemaker (CRT-P) is considered an effective treatment for heart failure (HF). Adding implantable cardioverter defibrillators (CRT-D) may further reduce the risk of sudden cardiac death (SCD). However, economic evaluations have shown t

  20. The mismatch between patient life expectancy and the service life of implantable devices in current cardioverter-defibrillator therapy: a call for larger device batteries.

    Science.gov (United States)

    Neuzner, Jörg

    2015-06-01

    In 2005, Bob Hauser published a paper in the Journal of the American College of Cardiology entitled "The growing mismatch between patient longevity and the service life of Implantable Cardioverter-Defibrillators". Now, nearly a decade later, I would like to perform a second look on the problem of a mismatching between ICD device service life and the survival of ICD recipients. Since 2005, the demographics of the ICD population has changed significantly. Primary prevention has become the dominant indication in defibrillator therapy and device implantation is indicated more and more in earlier stages of cardiac diseases. In former larger scale ICD trials, the patient average 5-year survival probability was in a range of 68-71%; in newer CRT-D trials in a range of 72-88%. Due to a progressively widened ICD indication and implantation preferentially performed in patients with better life expectancy, the problem of inadequate device service life is of growing importance. The early days of defibrillator therapy started with a generator volume of 145 ccm and a device service life life were similar challenges for the technicians. Today, we have reached a formerly unexpected extent of device miniaturization. However, technologic improvements were often preferentially translated in further device miniaturization and not in prolonging device service life. In his analysis, Bob Hauser reported a prolonged device service life of 2.3 years in ICD models with a larger battery capacity of 0.54 up to 0.69 Ah. Between 2008 and 2014, several studies had been published on the problem of ICD longevity in clinical scenarios. These analyses included "older" and currently used single chamber, dual chamber and CRT devices. The reported average 5-year device service life ranged from 0 to 75%. Assuming today technology, larger battery capacities will only result in minimal increase in device volume. Selected ICD patients may further benefit from device miniaturization-but the vast majority

  1. Implantable cardioverter-defibrillator therapy in a 34-year-old patient with eating disorders and after the third sudden cardiac arrest.

    Science.gov (United States)

    Piotrowicz, Ewa; Orzechowski, Piotr; Bilinska, Maria; Przybylski, Andrzej; Szumowski, Lukasz; Piotrowicz, Ryszard

    2015-03-01

    Eating disorders (ED) such as anorexia nervosa and bulimia are psychiatric diseases associated with the highest mortality rate of any other psychiatric disorders. More recently, long-term outcome studies with follow-up of over 20 years report a mortality of between 15% and 18% (Casiero and Frishman, Cardiol Rev 14(5), 227, 2006). The sudden death secondary to arrhythmias is often the cause of death in these patients (Casiero and Frishman, Cardiol Rev 14(5), 227, 2006). A case of life-threatening ventricular arrhythmia (VA) in a patient with ED is presented. Clinical records (cardiologic, psychiatric), electrocardiograms, echocardiogram, coronary angiogram, cardiac magnetic resonance, and endocrine diagnostics were performed. Finally a cardioverter-defibrillator (ICD) was implanted in the patient after her third cardiac arrest. An optimal approach to antiarrhythmic therapy in such patients is a real challenge for a cardiologist.

  2. Desfibrilador cardioversor automático implantável: experiência inicial Implantable cardioverter defibrillator: initial experience

    Directory of Open Access Journals (Sweden)

    Victor BAUER JÚNIOR

    1999-04-01

    Full Text Available Este estudo tem por objetivo demonstrar o protocolo de implante, técnica utilizada, avaliação dos parâmetros iniciais do implante de desfibrilador cardioversor automático implantável (DCAI e seguimento precoce dos 15 pacientes operados em nosso Serviço. O implante transvenoso nessa série de pacientes obteve sucesso em 14 casos. O limiar de desfibrilação teve média de 8,05 ± 4,60 Joules, onda R 16,00 ± 4,32 mV, "slew rate" 1,25 ± 0,29 V/s, limiar de comando de 0,65 ± 0,80 Volts e resistência de 620,00 ± 102,77 Ohms. O tempo médio de implante foi de 164,17 ± 71,15 minutos. Não ocorreu morte operatória, nem episódios de rejeição ou infecção. A média de seguimento foi de 18,79 ± 13,81 meses sendo que 9 pacientes receberam choques apropriados com reversão das arritmias. Choques inapropriados ocorreram em uma paciente devido à perda do limiar de sensibilidade do cardioversor. Observamos a facilidade técnica do implante utilizando o modelo Phylax 06 na região infraclavicular esquerda com eletrodo único, sendo o DCAI capaz de reconhecer e realizar a terapia de cardioversão ou desfibrilação com sucesso, sugerindo ser um método importante e eficaz para o tratamento dos pacientes que desenvolvem arritmias com alto risco de mortalidade em ambulatório.The implantable cardioverter-defibrillator (ICD is gaining increasing significance in therapy of life-threatening ventricular arrhythmias. Mirowski started to develop experimental automatic implantable defibrillators in the seventies. In 1980, the first human implant of an automatic implantable defibrillator was done by the team of Mirowski in Baltimore, USA. The purpose of this report is to examine 15 implantation at our Institution. Adequate defibrillation thresholds with were obrtained mean 8.0 Joules, slew rate 1.25 V/s and impedance of 620 Ohms. All implants were performed with non-thoracotomy lead, two abdominal implantations and three left pectoral implantations

  3. Clinical effects and implications of cardiac rehabilitation for implantable cardioverter defibrillator patients

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Moons, Philip; Christensen, Anne Vingaard

    2015-01-01

    further explained by the qualitative findings. Patients with better physical health learned how to interpret body signals and adjust exercise behavior and experienced increased physical capacity. Those with better mental health received support that assisted them to cope with the possibility of shock...... rehabilitation and usual care was found in physical capacity and general and mental health. However, the clinical effect sizes of these findings were not investigated, and the findings from the quantitative and qualitative analyses were not triangulated to address the issue of whether the qualitative results......-time implantable cardioverter defibrillator implantation were randomized (1:1) to comprehensive cardiac rehabilitation (12 weeks of exercise training and 1 year of psychoeducational follow-up) versus treatment as usual. Two primary outcomes, perceived health (Short Form-36) and peak oxygen uptake, were used. Cohen...

  4. Prophylactic implantable defibrillator in patients with arrhythmogenic right ventricular cardiomyopathy/dysplasia and no prior ventricular fibrillation or sustained ventricular tachycardia.

    LENUS (Irish Health Repository)

    Corrado, Domenico

    2010-09-21

    The role of implantable cardioverter-defibrillator (ICD) in patients with arrhythmogenic right ventricular cardiomyopathy\\/dysplasia and no prior ventricular fibrillation (VF) or sustained ventricular tachycardia is an unsolved issue.

  5. Pacemakers and implantable cardioverter defibrillators, unknown to chest radiography: Review, complications and systematic reading

    Energy Technology Data Exchange (ETDEWEB)

    Alandete Germán, Salvador Pascual, E-mail: salaiger@gmail.com; Isarria Vidal, Santiago, E-mail: isarria@comv.es; Domingo Montañana, María Luisa, E-mail: domingo.luimon@gmail.com; De la vía Oraá, Esperanza, E-mail: esviao82@gmail.com; Vilar Samper, José, E-mail: vilarsamper@gmail.com

    2015-03-15

    Highlights: •Radiologists have an important function in the evaluation of these devices. •We revise their radiological appearances and possible complications. •The knowledge in normal aspects and complications is important for radiologist. •To ensure an accurate reading of the chest x-ray, we present a systematic approach. -- Abstract: Chest X-ray is the imaging technique of choice for an initial study of pacemakers and implantable cardio-defibrillators (ICD). Radiologists have an important role in the evaluation of its initial placement and in the assessment during its follow-up. For this reason, it is necessary to know not only the different existing devices and its components but also the reasons of malfunction or possible complications. The purpose of this article is to do a systematic review of the different types of pacemakers and ICD. We review their usual radiological appearances, the possible complications which might take place and its causes of malfunctioning.

  6. Psychological intervention following implantation of an implantable defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van den Broek, Krista C; Sears, Samuel F

    2007-01-01

    The medical benefits of the implantable cardioverter defibrillator (ICD) are unequivocal, but a subgroup of patients experiences emotional difficulties following implantation. For this subgroup, some form of psychological intervention may be warranted. This review provides an overview of current...... evidence on the efficacy of psychological intervention in ICD patients and recommendations for future research....

  7. General anaesthesia for insertion of an automated implantable cardioverter defibrillator in a child with Brugada and autism

    Directory of Open Access Journals (Sweden)

    Shwetal Goraksha

    2010-01-01

    Full Text Available A 14-year-old autistic boy presented with acute gastroenteritis and hypotension. The electrocardiogram showed a ventricular fibrillation rhythm - he went into cardiorespiratory arrest and was immediately resuscitated. On investigation, the electrocardiogram showed a partial right bundle branch block with a "coved" pattern of ST elevation in leads v 1 -v 3 . A provisional diagnosis of Brugada syndrome was made, for which an automated implantable cardioverter defibrillator (AICD implantation was advised. Although the automated implantable cardioverter defibrillator implantation is usually performed under sedation, because this was an autistic child, he needed general anaesthesia. We performed the procedure uneventfully under general anaesthesia and he was discharged after a short hospital stay.

  8. Selective left ventricular sensing lead implantation to overcome undersensing of ventricular fibrillation during implantable cardioverter defibrillator implantation.

    Science.gov (United States)

    Steinberg, Christian; Philippon, François; O'Hara, Gilles; Molin, Franck

    2013-06-01

    Accurate sensing of malignant arrhythmia is critical for the appropriate delivery of therapy from implantable cardioverter defibrillators, and undersensing of ventricular tachyarrhythmias can have catastrophic consequences. Here, we present an unusual case of ventricular fibrillation undersensing from the right ventricular lead at multiple different implantation sites because of very low amplitude voltage signals during induced ventricular fibrillation. A left ventricular sensing electrode was implanted to allow correct sensing and therapy delivery.

  9. Obstetric hemorrhage in a case of hypertrophic obstructive cardiomyopathy with automatic implantable cardioverter defibrillator: Anaesthesia and intensive care management.

    Science.gov (United States)

    Mishra, Sandeep Kumar; Bhat, Ravindra R; Kavitha, Jayaram; Kundra, Pankaj; Parida, Satyen

    2016-01-01

    The physiological changes occurring during pregnancy and labor may reveal or exacerbate the symptoms of hypertrophic obstructive cardiomyopathy (HOCM). The addition of obstetric hemorrhage to this presents a unique challenge to the anesthesiologists and intensivists managing these patients in the operation theatres and the Intensive Care Units. Here we present a case of HOCM with automatic implantable cardioverter defibrillator in situ and postpartum hemorrhagic shock.

  10. In Rhythm : the Impact of an ICD on Quality of Life

    NARCIS (Netherlands)

    Kamphuis, Helena Christina Margien

    2005-01-01

    The main purpose of this study was to investigate quality of life in patients' who had survived a cardiac arrest and were treated with an implantable Cardioverter Defibrillator (ICD). Two groups were compared, those that had received an ICD with those that were treated otherwise. This thesis compris

  11. Prediction of Appropriate Shocks Using 24-Hour Holter Variables and T-Wave Alternans After First Implantable Cardioverter-Defibrillator Implantation in Patients With Ischemic or Nonischemic Cardiomyopathy.

    Science.gov (United States)

    Seegers, Joachim; Bergau, Leonard; Expósito, Pascal Muñoz; Bauer, Axel; Fischer, Thomas H; Lüthje, Lars; Hasenfuß, Gerd; Friede, Tim; Zabel, Markus

    2016-07-01

    In patients treated with implantable cardioverter defibrillator (ICD), prediction of both overall survival and occurrence of shocks is important if improved patient selection is desired. We prospectively studied the predictive value of biomarkers and indexes of cardiac and renal function and spectral microvolt T-wave alternans testing and 24-hour Holter variables in a population who underwent first ICD implantation. Consecutive patients in sinus rhythm with ischemic or dilated cardiomyopathy scheduled for primary or secondary prophylactic ICD implantation were enrolled. Exercise microvolt T-wave alternans and 24-hour Holter for number of ventricular premature contractions (VPCs), deceleration capacity, heart rate variability, and heart rate turbulence were done. Death of any cause and first appropriate ICD shock were defined as end points. Over 33 ± 15 months of follow-up, 36 of 253 patients (14%) received appropriate shocks and 39 of 253 patients (15%) died. Only 3 of 253 patients (1%) died after receiving at least 1 appropriate shock. In univariate analyses, New York Heart Association class, ejection fraction, N-terminal pro brain-type natriuretic peptide (NT-proBNP), renal function, ICD indication, deceleration capacity, heart rate variability, and heart rate turbulence were predictive of all-cause mortality and VPC number and deceleration capacity predicted first appropriate shock. NT-proBNP (≥1,600 pg/ml) was identified as the only independent predictor of all-cause mortality (hazard ratio 3.0, confidence interval 1.3 to 7.3, p = 0.014). In contrast, VPC number predicted appropriate shocks (hazard ratio 2.3, confidence interval 1.0 to 5.5, p = 0.047) as the only independent risk marker. In conclusion, NT-proBNP is a strong independent predictor of mortality in a typical prospective cohort of newly implanted patients with ICD, among many electrocardiographic and clinical variables studied. Number of VPCs was identified as a predictor of appropriate shocks

  12. Is metal artefact reduction mandatory in cardiac PET/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

    Energy Technology Data Exchange (ETDEWEB)

    Ghafarian, Pardis [Shahid Beheshti University, Department of Radiation Medicine, Tehran (Iran, Islamic Republic of); Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Tehran University of Medical Sciences, Research Center for Science and Technology in Medicine, Tehran (Iran, Islamic Republic of); Aghamiri, S.M.R. [Shahid Beheshti University, Department of Radiation Medicine, Tehran (Iran, Islamic Republic of); Ay, Mohammad R. [Tehran University of Medical Sciences, Research Center for Science and Technology in Medicine, Tehran (Iran, Islamic Republic of); Tehran University of Medical Sciences, Department of Medical Physics and Biomedical Engineering, Tehran (Iran, Islamic Republic of); Tehran University of Medical Sciences, Research Institute for Nuclear Medicine, Tehran (Iran, Islamic Republic of); Rahmim, Arman [Johns Hopkins University, Department of Radiology, Baltimore, MD (United States); Schindler, Thomas H. [Geneva University, Cardiovascular Center, Nuclear Cardiology, Geneva (Switzerland); Ratib, Osman [Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Zaidi, Habib [Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Geneva University, Geneva Neuroscience Center, Geneva (Switzerland)

    2011-02-15

    Cardiac PET/CT imaging is often performed in patients with pacemakers and implantable cardioverter defibrillator (ICD) leads. However, metallic implants usually produce artefacts on CT images which might propagate to CT-based attenuation-corrected (CTAC) PET images. The impact of metal artefact reduction (MAR) for CTAC of cardiac PET/CT images in the presence of pacemaker, ICD and ECG leads was investigated using both qualitative and quantitative analysis in phantom and clinical studies. The study included 14 patients with various leads undergoing perfusion and viability examinations using dedicated cardiac PET/CT protocols. The PET data were corrected for attenuation using both artefactual CT images and CT images corrected using the MAR algorithm. The severity and magnitude of metallic artefacts arising from these leads were assessed on both linear attenuation coefficient maps ({mu}-maps) and attenuation-corrected PET images. CT and PET emission data were obtained using an anthropomorphic thorax phantom and a dedicated heart phantom made in-house incorporating pacemaker and ICD leads attached at the right ventricle of the heart. Volume of interest-based analysis and regression plots were performed for regions related to the lead locations. Bull's eye view analysis was also performed on PET images corrected for attenuation with and without the MAR algorithm. In clinical studies, the visual assessment of PET images by experienced physicians and quantitative analysis did not reveal erroneous interpretation of the tracer distribution or significant differences when PET images were corrected for attenuation with and without MAR. In phantom studies, the mean differences between tracer uptake obtained without and with MAR were 10.16{+-}2.1% and 6.86{+-}2.1% in the segments of the heart in the vicinity of metallic ICD or pacemaker leads, and were 4.43{+-}0.5% and 2.98{+-}0.5% in segments far from the leads. Although the MAR algorithm was able to effectively improve

  13. Sustaining cyborgs: sensing and tuning agencies of pacemakers and implantable cardioverter defibrillators.

    Science.gov (United States)

    Oudshoorn, Nelly

    2015-02-01

    Recently there has been a renewed interest in cyborgs, and particularly in new and emerging fusions of humans and technologies related to the development of human enhancement technologies. These studies reflect a trend to follow new and emerging technologies. In this article, I argue that it is important to study 'older' and more familiar cyborgs as well. Studying 'the old' is important because it enables us to recognize hybrids' embodied experiences. This article addresses two of these older hybrids: pacemakers and implantable cardioverter defibrillators inserted in the bodies of people suffering from heart-rhythm disturbances. My concern with hybrid bodies is that internal devices seem to present a complex and neglected case if we wish to understand human agency. Their 'users' seem to be passive because they cannot exert any direct control over the working of their devices. Technologies inside bodies challenge a longstanding tradition of theorizing human-technology relations only in terms of technologies external to the body. Cyborg theory is problematic as well because most studies tend to conceptualize the cyborg merely as a discursive entity and silence the voices of people living as cyborgs. Inspired by feminist research that foregrounds the materiality of the lived and intimate relations between bodies and technologies, I argue that creating these intimate relations requires patients' active involvement in sustaining their hybrid bodies. Based on observations of these monitoring practices in a Dutch hospital and interviews with patients and technicians, the article shows that heart cyborgs are far from passive. On the contrary, their unique experience in sensing the entangled agencies of technologies and their own heart plays a crucial role in sustaining their hybrid bodies.

  14. Risk of chronic anxiety in implantable defibrillator patients

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; den Broek, Krista C van; Theuns, Dominic A M J

    2011-01-01

    Little is known about the prevalence of chronic anxiety in patients with an implantable cardioverter defibrillator (ICD). In a multi-center, prospective study, we examined 1) the prevalence of chronic anxiety (i.e., patients anxious at implantation and 12 months), and 2) predictors of chronic...... anxiety....

  15. Relevance of guideline-based ICD indications to clinical practice.

    Science.gov (United States)

    Al-Jefairi, Nora; Burri, Haran

    2014-01-01

    The implantable cardioverter-defibrillator (ICD) has established itself as life-saving therapy in patients at risk for sudden cardiac death. Remarkable technological advances have made ICDs easier and safer to implant, with improved therapeutic and diagnostic functions and reduced morbidity. Guidelines on ICD indications have been proposed by American and European scientific societies since a number of years, based upon trials and expert opinion. In the context of variable economic and political constraints, it is questionable whether these guidelines may be applied to all settings. This review discusses the guideline-based indications, critically examines their applicability to clinical practice, and discusses alternatives to ICD therapy.

  16. The gulf implantable cardioverter-defibrillator registry: Rationale, methodology, and implementation

    Directory of Open Access Journals (Sweden)

    Alawi A Alsheikh-Ali

    2015-01-01

    Conclusions: Gulf ICD is the first prospective, observational, multi-center, and multinational study of the characteristics and, the outcomes of patients receiving ICDs in the Arab Gulf region. The study will provide valuable insights into the utilization of and outcomes related to ICD therapy in the Gulf region.

  17. Programming implantable cardioverter-defibrillators in primary prevention: higher or later.

    Science.gov (United States)

    Clementy, Nicolas; Pierre, Bertrand; Simeon, Edouard; Lallemand, Bénédicte; Fauchier, Laurent; Babuty, Dominique

    2014-05-01

    Defibrillator shocks, appropriate or not, are associated with significant morbidity, as they decrease quality of life, can be involved in depression and anxiety, and are known to be proarrhythmic. Most recent data have even shown an association between shocks and overall mortality. As opposed to other defibrillator-related complications, the rate of inappropriate and unnecessary shocks can (and should) be decreased with adequate programming. This review focuses on the different programming strategies and tips available to reduce the rate of shocks in primary prevention patients with left ventricular dysfunction implanted with a defibrillator, as well as some of the manufacturers' device specificities.

  18. Poor perceived social support in implantable cardioverter defibrillator (ICD) patients and their partners

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Spinder, Helle; Erdman, Ruud A M;

    2009-01-01

    Social support is a known buffer of psychological distress and has also been shown to influence adverse medical outcomes.......Social support is a known buffer of psychological distress and has also been shown to influence adverse medical outcomes....

  19. The Cause Analysis and Countermeasures of Frequent Shocks in Patients with Implantable Cardioverter Defibrillator%埋藏式心脏除颤器患者频繁电击原因分析及对策

    Institute of Scientific and Technical Information of China (English)

    吴冬燕; 邢彩耐; 卢凤民; 付乃宽; 许静

    2014-01-01

    Objective To investigate the cause and countermeasures of frequent shocks in patients with implantable cardioverter defibrillators (ICD). Methods Eighty ICD patients with heart failure and malignant ventricular arrhythmias were followed up, including sixty-two male and eighteen female patients. There were 35 patients with single-chamber ICD, 23 with dual-chamber ICD and 22 with three-chamber ICD. Patients in this study were followed up for 1-6 years to analyze the reasons for ICD discharge. According to the specific circumstances, patients were treated. Results Twenty-three pa-tients in 80 patients suffered from shock treatment. Ten patients (12.5%) experienced frequent shocks. The causes of fre-quent shock included repeated episodes of ventricular tachycardia, invalid shock due to increased defibrillation threshold (DF) and false identification of the frequent episodes of paroxysmal ventricular tachycardia or arrhythmias. The management included the identification process adjustment of ventricular tachycardia and supraventricular tachycardia, increased num-bers of beats of ventricular tachycardia judgment and increase the basic pacing rate. The anti-arrhythmic drugs should be combinedly used, especially metoprolol and amiodarone. The ICD shock was significantly reduced after parameter optimiza-tion and anti-arrhythmic therapy. Conclusion The ICD shocks were effectively reduced with rational use of anti-arrhyth-mic drugs and valid ICD programming.%目的:探讨植入埋藏式心脏除颤器(ICD)的患者出现频繁放电的原因及处理方法。方法随访80例因心力衰竭或恶性室性心律失常植入ICD的患者,男62例,女18例,其中单腔ICD 35例,双腔ICD 23例,三腔ICD (CRTD)22例,随访1~6年,了解ICD的放电原因,并根据具体情况进行治疗。结果80例患者中有23例患者遭受电击,其中10例为频繁电击(24 h内电击≥3次或1年内电击≥5次),均为心脏猝死二级预防患者。

  20. The Screen-ICD trial. Screening for anxiety and cognitive therapy intervention for patients with implanted cardioverter defibrillator (ICD)

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Herning, Margrethe; Svendsen, Jesper Hastrup;

    2016-01-01

    by Structured Clinical Interview for DSM Disorders (SCID). (3) Investigator-initiated randomised clinical superiority trial with blinded outcome assessment, with 1:1 randomisation to cognitive–behavioural therapy (CBT) performed by a cardiac nurse with CBT training, plus usual care or usual care alone...

  1. [Positive microvolt T-wave alternans as a marker of ventricular arrhythmia trigering during cardioverter-defibrillator implantation].

    Science.gov (United States)

    Wierzbowski, Robert; Michałkiewicz, Dariusz; Cholewa, Marian; Jacewicz, Katarzyna; Gniłka, Anna; Adamus, Jerzy

    2006-10-01

    Microvolt T-wave alternans (MTWA) is promising method for noninvasive assessment of arrhythmic risk, but its role hasn't established yet. The aim of this study was to establish the MTWA potency to predict the ventricular arrhythmia triggering during implantable cordioverter-defibrillator (ICD) implantation. Material and metods. The study group consisted of 21 patients, aged 63.0+/-8.0 years; EF was 38.0+/-12.8%. Seventeen of them had a history of myocardial infarction and 4 had non-ischemic cardiomyopathy. The reason for ICD implantation were secondary prevention due to nonfatal cardiac arrest caused by VF/VT in nineteen patients and in two patients ICD was implanted because of unexplained syncope and low EF (protocol of 50 Hz BURST and T SHOCK was applied. After ICD implantation the following tests were performed: ECG with HR, QRS and QTc evaluation, 24-hour ECG Holter monitoring with HRV assessment and MTWA evaluation during treadmill exercise test. Results. In the group with VT/VF induced by less aggressive protocol (EPS), group I (n = 10) MTWA was present in nine patients, in one the result of MTWA was indeterminate. In the group with VT/VF induced by more aggressive protocol, group II (n = 11) MTWA was present in four patients, indeterminate in four and absent in three. There was a significant (p = 0.017) difference between group I and II in the frequency of positive result of MTWA. There were no differences between the two groups according to time domain parameters of HRV such as SDNN, RMSSD and PNN50 and QTc. There was a significant difference between the two groups in time duration of QRS complexes, 118.9+/-14.7 vs. 105.6+/-11.5 accordingly (p more easily inducible by electrophysiologic study during ICD implantation. It is easier to induce ventricular arrhythmia when QRS complexes are wider, irrelevant to left ventricular dysfunction and autonomic function of the heart.

  2. Nursing care of patients receiving implantable cardioverter defibrillator implantation//%心脏转复除颤器植入术患者的护理

    Institute of Scientific and Technical Information of China (English)

    李燕林; 丁莉; 陈琴

    2011-01-01

    Objective To summarize the main nursing measures of implantable cardioverter defibrillator (ICD) implantation and to highlight the maneuvers of commonly seen complications. Methods Seven cases were successfully resuscitated after sudden cardiac death. They received ICD implantation. Before the procedure, patients were closely monitored with ECG and observed; after the procedure, patients had ECG and blood pressure monitoring, and the changes in heart rates and rhythm were closely observed.Nurses instructed patients to have good rest, gave diet guidance, helped them handle pain, and kept close eyes on vital signs and delivered health education. Nurses also handled complications and accidents timely. Results The 7 patients had a hospital stay of 1430 d. All patients were symptomatic in New York Heart Association Functional Class Ⅱ or Ⅲ at discharge. Patients were followed up 2-52 months. One cases died from lung infection and pump failure. The other six patients experienced 4 times of ICD shock delivery, 3 ventricular tachycardia, 1 supraventricular tachycardia. The quick-beating heart turned into sinus rhythm after shock delivery. One case developed hallucinations of electric shock; one case had effusion of the pouch. Both the above cases received symptomatic treatment. Conclusion The complications of ICD implantation be reduced by strengthening observation of vital signs of patients, giving scrupulous fundamental nursing and psychological nursing, and taking preventive precautions, which also lengthens the service life of the ICD system.%目的 总结植入型心脏转复除颤器(1CD)植入术的护理要点和常见并发症的处理方法.方法 对收治的心源性猝死抢救成功的7例患者行ICD植入术,术前加强心电监护及病情观察;术后持续心电、血压监测,尤其注意观察心率、心律的变化,做好休息与饮食、疼痛及生命体征护理和健康教育,及时处理常见并发症和意外.结果 7例患者住院14

  3. Dental management of a patient fitted with subcutaneous Implantable Cardioverter Defibrillator device and concomitant warfarin treatment

    Directory of Open Access Journals (Sweden)

    Altaf Hussain Shah

    2015-07-01

    This article presents the dental management of a 60 year-old person with an ICD and concomitant anticoagulant therapy. The patient was on multiple medications and was treated for a grossly neglected mouth with multiple carious root stumps. This case report outlines the important issues in managing patients fitted with an ICD device and at a risk of sudden cardiac death.

  4. Late Development of a Bronchocutaneous Fistula due to an Epicardial Cardioverter-Defibrillator Lead

    Directory of Open Access Journals (Sweden)

    Vasileios Patris

    2015-10-01

    Full Text Available Cutaneous complications caused by a pacemaker or defibrillator are widely documented, but the development of a bronchocutaneous fistula has never been described before. We report the case of a 79-year-old man who was admitted to our hospital because of a seemingly superficial cutaneous infection, externalized defibrillator leads, and hemoptysis. Bronchoscopical investigation proved the existence of the fistula, which connected the epicardium, the left main bronchus, and the aforementioned site of skin infection. The patient refused an operation for the complete removal of the epicardial defibrillator and was treated conservatively. This case demonstrated that the long-term presence of foreign bodies in the epicardium may cause serious complications

  5. Employment Status and Sick Leave After First-Time Implantable Cardioverter Defibrillator Implantation

    DEFF Research Database (Denmark)

    Christensen, Anne Vinggaard; Øhlers, Anne Alexandrine; Zwisler, Ann-Dorthe;

    2017-01-01

    . METHOD: Patients with first-time ICD implantation were randomized to comprehensive cardiac rehabilitation or usual care. One year after ICD implantation, patients answered questions about employment status and sick leave. Differences were tested using the Student t test and the χ test. Predictors...... of employment status and sick leave were tested using logistic regression and linear regression models. RESULT: A total of 196 patients were randomized. The questionnaire was completed by 138 patients (70%). In total, 47% had worked before ICD implantation. After 1 year, 81% were still working and their mean...

  6. A prospective study of anxiety in ICD patients with a pilot randomized controlled trial of cognitive behavioral therapy for patients with moderate to severe anxiety

    DEFF Research Database (Denmark)

    Qintar, Mohammed; George, Jason J; Panko, Melanie

    2015-01-01

    PURPOSE: Stress and anxiety are potential consequences from arrhythmias and implantable cardioverter defibrillator (ICD) shocks that can contribute to substantial morbidity. We assessed anxiety associated with an ICD and whether cognitive behavioral therapy (CBT) reduces anxiety. METHODS: The stu......Trials.gov identifier: NCT00851071. URL: http://clinicaltrials.gov/ct2/show/NCT00851071?term=anxiety+in+icd+patients+cleveland+clinic&rank=1....

  7. [Implantation of a biventricular ICD in a patient with dextrocardia with situs inversus].

    Science.gov (United States)

    Vurgun, Veysel Kutay; Gerede, Menekşe; Altın, Ali Timuçin; Candemir, Başar; Akyürek, Ömer

    2015-01-01

    In order to reduce sudden cardiac death and heart failure symptoms, biventricular implantable cardioverter defibrillator (ICD) implantation is a treatment method commonly used in selected patients with cardiomyopathy. The frequency of dextrocardia in congenital heart defects is approximately 0.4/10000. In this group, the frequency of cardiomyopathy development is rare. In this case report we present a patient with dextrocardia undergoing implantation of biventricular ICD.

  8. Ventricular Tachyarrhythmias and Mortality in Patients With an Implantable Cardioverter Defibrillator

    DEFF Research Database (Denmark)

    Mastenbroek, Mirjam H; Versteeg, Henneke; Jordaens, Luc

    2014-01-01

    .1] years) completed the Hospital Anxiety and Depression Scale 1 day before implantation. During follow-up, the ICD was interrogated at 3-month intervals. Cox proportional hazard regression analyses were used to examine the impact of depression on time to first appropriate ICD therapy and all-cause...... with an increased risk for all-cause mortality (unadjusted HR = 2.18, 95% CI = 1.36-3.49). Depression remained independently associated with all-cause mortality (HR = 1.94, 95% CI = 1.06-3.54, p = .031), after adjusting for demographic and clinical characteristics. Patients who remained depressed during the first 3...... months after implantation were at greatest risk for dying (HR = 2.88, 95% CI = 1.29-6.45, p = .010). Conclusions The current study showed that depression at the time of implant is not associated with time to first appropriate ICD therapy but almost doubled the risk for all-cause mortality in patients...

  9. Clinical observation and nursing of implantable cardioverter-defibrillator patients with oral anticoagulants in the peroperative period%ICD围术期未停口服抗凝药的临床观察和护理

    Institute of Scientific and Technical Information of China (English)

    孙丽; 冯婕; 陆敬平; 徐冬梅

    2012-01-01

    目的 探讨植入型心律转复除颤器(ICD)围术期未停口服抗凝药的临床观察和护理.方法 回顾ICD植入术35例患者,其中围术期未停抗凝药15例,总结护理要点和并发症的处理方法.结果 35例行ICD植入术患者均痊愈出院,随访患者无不良反应和并发症.结论 术前全面评估患者围术期是否停用或替代抗凝剂,同时做好患者教育及凝血监测工作,术后严密观察术区情况,发现异常及时处理.%Objective To explore the clinical manifestations and nursing of implantable car-dioverter- defibrillator (ICD) patients with oral anticoagulants in the peroperative period. Methods The clinical data of 35 ICD patients were reviewed. Among them, 15 patients continued the oral anticoagulants. The nursing highlights and the ways to deal with complications have been summarized. Results All patients were discharged from hospital with good recovery. Follow-up showed that there were no adverse reactions and complications. Conclusion Comprehensive assessment should be done to identify whether patients has discontinued oral anticoagulants or other substitutes in the perioperative period before surgery. Meanwhile, health education and coagulation should be properly managed. The progression of disease should be closely observed after surgery in case of e-mergencies.

  10. Clinical and psychological impact of prophylactic implantable cardioverter-defibrillators in a community heart failure population.

    LENUS (Irish Health Repository)

    Arnous, S

    2012-02-01

    AIMS: ICD implantation for primary prevention of sudden cardiac death in patients with left ventricular systolic dysfunction (ejection fraction <\\/= 35%) has increased since the publication of the SCD-HEFT and MADIT-II data. The aim of this study is to examine the effectiveness and safety of prophylactic ICD use in a community heart failure population and to assess the impact on patient\\'s quality of life. METHODS AND RESULTS: Seventy-one ICDs were inserted between the years 2002 and 2006. The mean follow-up from time of insertion was 24 +\\/- 11 months. Eighteen patients (25%) had potentially life-saving therapy. Seven (10%) patients received inappropriate shocks. Complications were encountered in five patients (7%). CONCLUSION: In a community heart failure population, prophylactic ICD implantation is associated with a high incidence of life-saving therapy, a low complication rate and a high level of tolerability. These data indicate translation of clinical trial benefits to the general heart failure population.

  11. Circadian variations in the occurrence of ventricular tachyarrhythmias in patients with implantable cardioverter defibrillators.

    Science.gov (United States)

    Kozák, Milan; Krivan, Lubomír; Semrád, Borivoj

    2003-03-01

    A circadian distribution has been demonstrated in episodes of sudden cardiac death, acute myocardial infarction, ventricular premature complexes, heart rate variability, and ventricular tachyarrhythmias. The aim of this study was to evaluate the circadian distribution of ventricular tachyarrhythmia episodes in a population of ICD patients. Data were gathered from 72 patients (55 men, 17 women; mean age 62.7 +/- 12.2 years, mean LVEF 0.0037 +/- 0.0011) with ICDs implanted for standard indications. Patients were followed every 3 months over a mean period of 21 +/- 12.8 months. At each examination, symptoms at arrhythmia onset and perception of ICD therapy were recorded, and the ICD memory was interrogated. During follow-up, 1,023 episodes' of malignant ventricular arrhythmias were detected and effectively terminated, 506 of which were fully analyzed. A morning peak in ventricular tachyarrhythmias was demonstrated between 7:00 and 11:00 AM, and an afternoon peak between 6:00 and 7:00 PM. A significantly lower occurrence of VT was observed at 1:00 AM and between 4:00 and 6:00 AM. A circadian distribution in the occurrence of ventricular tachycardias was found. The three striking features of the data are: the early morning peak (about three hours after waking up), relatively stable incidence throughout waking hours, and decline in incidence in the previous period.

  12. Patients' perspective on deactivation of the implantable cardioverter-defibrillator near the end of life

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Chaitsing, Rismy; Szili-Torok, Tamas

    2013-01-01

    (67%) completed the survey. Most patients (68%) were aware that it is possible to turn the ICD off, and 95% believed it is important to inform patients about the possibility. Of the patients completing the survey, 84% indicated a choice for or against deactivation. Psychological morbidity...

  13. Temporal complexity of repolarization and mortality in patients with implantable cardioverter defibrillators.

    Science.gov (United States)

    Perkiomaki, Juha S; Couderc, Jean-Philippe; Daubert, James P; Zareba, Wojciech

    2003-10-01

    Increased repolarization variability has been observed in various cardiac conditions. However, data on its relation to heart rate variability and on its value in predicting adverse outcomes in high risk patients are limited. Forty-seven patients with decreased left ventricular function and ICDs had high resolution 10-minute ECG recordings and were followed for 781 +/- 258 days (mean +/- SD) on average. The interval from the R peak to the T wave peak with maximum amplitude (RTmax) and from the R peak to the T wave offset (RToff) were determined automatically on a beat-to-beat basis. Temporal beat-to-beat RTmax and RToff variability were analyzed using traditional summary statistics, a complexity measure (approximate entropy [ApEn]), and the short-term scaling exponent (alpha1). Eight (17%) patients died and 16 (34%) patients experienced death/appropriate ICD shock during follow-up. RTmax-ApEn was significantly higher in patients who died compared with patients who survived (1.24 +/- 0.13 vs 1.01 +/- 0.21, respectively, P=0.008). When RTmax-ApEn was tested together with the alpha1 of the RR intervals, occurrence of ventricular arrhythmias before ICD implantation, and beta-blockers usage in the Cox regression analysis, it still independently predicted mortality; hazard ratio=3.36 (1.28-8.83, 95% CI, P=0.014) for every 0.10-increase in RTmax-ApEn. None of the repolarization variability parameters independently predicted death/appropriate ICD shocks. Increased temporal complexity of repolarization (RTmax-ApEn) independently predicts mortality in ICD patients.

  14. Longevity of the Subcutaneous Implantable Defibrillator Long-Term Follow-Up of the European Regulatory Trial Cohort

    NARCIS (Netherlands)

    Theuns, Dominic A. M. J.; Crozier, Ian G.; Barr, Craig S.; Hood, Margaret A.; Cappato, Riccardo; Knops, Reinoud E.; Maass, Alexander H.; Boersma, Lucas V. A.; Jordaens, Luc

    2015-01-01

    Background The recent advent of subcutaneous implantable cardioverter defibrillators (S-ICDs) has provided investigators with a safe and effective new therapy in patients at risk of sudden cardiac death. At present, no data are available with regard to the longevity of these new devices. This study

  15. Effects of an alert system on implantable cardioverter defibrillator-related anxiety

    DEFF Research Database (Denmark)

    Duru, Firat; Dorian, Paul; Favale, Stefano

    2010-01-01

    failing to receive needed therapy for the same reason. New devices include programmable vibrating patient notifiers (PN), which, by warning patients of a possible device dysfunction, might lower device-related anxiety. PAtient NOtifier feature for Reduction of Anxiety: a Multicentre ICD study (PANORAMIC......) is a multicentre, randomized, clinical trial designed to examine the effects of the awareness of an active vibrating alert system on device-related anxiety....

  16. A Clinical Review of Implantable Cardioverter Defibrillators and Bi-Ventricular Pacemakers at one Institute

    Directory of Open Access Journals (Sweden)

    Ahmad Nasir

    2010-01-01

    Full Text Available Background: ICD/BVP indications are expanding. They areexpensive devices and historically, morbidities associated withtheir use were high. The starting experience at the Gold CoastHospital is being reviewed.Methods: A retrospective chart review of all the ICD/BVPsimplanted in the Gold Coast Hospital from 06/07/2007 –17/06/2008, with special emphasis on device indications andcomplications.Results: Devices implanted were (31. Primary preventiondevices (67%, secondary prevention devices (33%.Indications were; Non-ischemic Dilated Cardiomyopathy(35%, Out-of-hospital Cardiac Arrest (26%, Conscious VT(13%, Ischemic Dilated Cardiomyopathy (10%, In-hospitalCardiac Arrest (6%, Long-QT Syndrome (6% andCatecholamine-related Polymorphic VT (3%. Majorcomplications reported; lung contusion (1, left haemothorax(1, failed coronary sinus lead positioning (2, lead repositioning(2, atrial lead removal (1, left subclavian veinthrombosis (1, lead malfunction leading to VT under sensingand syncope (1. Device-administered therapies were eight;Inappropriate discharges (5, Appropriate discharges (1,successful Anti-tachycardia Pacing (2.Conclusions: We believe that ICDs are very effective lifesavingdevices but unfortunately they still are very expensiveand their use can be associated with significant morbiditiesespecially during the learning curve.

  17. Inhibition of bradycardia pacing caused by far-field atrial sensing in a third-generation cardioverter defibrillator with an automatic gain feature.

    Science.gov (United States)

    Curwin, J H; Roelke, M; Ruskin, J N

    1996-01-01

    The diagnostic accuracy of implantable cardioverter defibrillators may be improved by automatically adjusting gain algorithms, which in general reduce the likelihood of oversensing while maintaining the ability to detect the low amplitude signals associated with ventricular fibrillation. We present a patient with a third-generation device who developed prolonged ventricular asystole arising as a complication of the automatic gain feature. During asystole the device automatically increased sensitivity in order to prevent undersensing of ventricular fibrillation, which in this case resulted in far-field sensing of atrial activity and inhibition of ventricular pacing.

  18. Role of implantable cardioverter defibrillator therapy in patients with long QT syndrome%植入型心律转复除颤器在长QT综合征患者中的应用

    Institute of Scientific and Technical Information of China (English)

    孙奇; 陈柯萍; 陈若菡; 华伟; 浦介麟; 张澍

    2008-01-01

    Objective To observe the role of implantable cardioverter defibrillator (ICD) therapy in patients with long QT syndrome. Methods ICD were planted in eight patients [4 men,4 women, mean age (27.3±25.9) years] with long QT syndrome. In the follow-up,the parameters of ICD were adjusted according to ICD therapy. Result During the follow-up of (27.3±25.9)months, ICD recorded 101 VT/VF episodes in 3 patients. With the traditional ICD programming,44 VF episodes were recorded. After the device parameters were adjusted according the VF episodes,57 VT and 2 VF episodes were recorded,most of them serf-terminated or terminated by low-energy shock. Electrical storm was presented in a patient,and we terminated it by increas-ing the base pacing rate. Inappropriate shocks due to T-wave oversensing were found in two patients,and it was avoided through adjusting the post-sensed Decay Delay. Conclusion Optimal device programming according to ICD therapy significantly decreases inappropriate ICD shocks and fewer unnecessary battery depletion and un-necessary shocks.%目的 总结阜外心血管病医院应用植入型心律转复除颤器(ICD)治疗长QT综合征(LQTS)患者的经验.方法 8例LQTS患者接受了ICD治疗,平均年龄(38.9±16.7)岁.在随访期间,根据具体情况,调整ICD的各项程控参数.结果 平均随访(27.3±25.9)个月,有3例患者出现了101次室性心动过速/心室颤动(VT/VF)事件.在出厂程控参数下,共记录到44次VF事件.重新设置VT/VF的识别及治疗参数后,共记录到57次VT事件,2次VF事件,大部分自行终止或经低能量转复成功.1例患者术后出现了电风暴,通过快速心室起搏,终止了尖端扭转性室性心动过速(Tdp)的反复发作.2例患者发生了因T波误感知导致的ICD误放电,通过延长感知灵敏度自动调整延迟,从而避免了T波误感知.结论 针对LQTS患者的发病特点,调整ICD的程控参数,可以提高疗效并减少ICD误放电.

  19. Erfahrung mit der Extraktion von transvenösen Kardioverter-Defibrillator (ICD Sonden

    Directory of Open Access Journals (Sweden)

    Dörnberger V

    1999-01-01

    Full Text Available Die ICD-Therapie ist ein bewährtes Verfahren zur Behandlung lebensbedrohlicher ventrikulärer Herzrhythmusstörungen. Defekte der komplex aufgebauten transvenösen Sondensysteme sind beschrieben. Meist ist eine komplette Entfernung defekter Sonden sinnvoll. Wir berichten über unsere Erfahrung mit der Entfernung von 13 transvenösen Elektrodensystemen. In 7 Fällen handelt es sich um eine Endotak C 0072 Sonde (CPI/Guidant und in 6 Fällen um eine Medtronic Transvene 6936 Elektrode. Das Sondenalter zum Zeitpunkt der Extraktion lag zwischen 1,5 und 77,6 Monaten (Mittelwert 36,3 ± 18. Als Extraktionshilfen wurden das VascoExtor Stylet S (Vascomed in 6 Fällen und das Byrd Locking-Stylet 0.017 (0.018 inches (Cook in 4 Fällen verwendet. Alle Extraktionen erfolgten unter transösophagealem Echokardiographie-Monitoring (TEE und Herz-Lungenmaschinen-Bereitschaft (HLM. Ohne Dilatations-Sheath war eine Extraktion nur innerhalb der ersten 3 Monate nach Implantation möglich (n = 3. Ein besonderes Problem stellt der im Vergleich zum Sondenkörper größere Durchmesser der Schockwendel dar, da die Sonde im Verlauf von einem Bindegewebsmantel fest umschlossen und mit der Venenwand verwachsen ist. Mit dem Byrd Dilatator-Schleusenset 10,0 Fr, 11,5 Fr und 13,0 Fr war in allen Fällen eine Lösung von der Venenwand möglich. Eine Extraktion einer Sonde (Medtronic Transvene war nach auswärtigen Vorversuchen mit Zerstörung der inneren Wendel nicht mehr möglich. In einem weiteren Fall konnten zwar die venösen Wandadhäsionen gelöst werden, die distale Schockwendel war jedoch in voller Länge mit dem Endokard verwachsen und konnte nur in einer offenen Herzoperation entfernt werden. In keinem Fall kam es zu einem bedeutsamen Perikarderguß. Kein Patient verstarb in Folge der Sondenextraktion. Zusammenfassend ist die Extraktion von ICD Sonden auch lange nach Implantation möglich. Trotz unserer relativ guten Erfahrung mit der Extraktion von ICD Sonden sollte

  20. Protein Biomarkers Identify Patients Unlikely to Benefit from Primary Prevention ICDs: Findings from the PROSE-ICD Study

    Science.gov (United States)

    Cheng, Alan; Zhang, Yiyi; Blasco-Colmenares, Elena; Dalal, Darshan; Butcher, Barbara; Norgard, Sanaz; Eldadah, Zayd; Ellenbogen, Kenneth A.; Dickfeld, Timm; Spragg, David D.; Marine, Joseph E.; Guallar, Eliseo; Tomaselli, Gordon F.

    2015-01-01

    Background Primary prevention implantable cardioverter defibrillators (ICDs) reduce all-cause mortality but the benefits are heterogeneous. Current risk stratification based on left ventricular ejection fraction has limited discrimination power. We hypothesize that biomarkers for inflammation, neurohumoral activation and cardiac injury can predict appropriate shocks and all-cause mortality in patients with primary prevention ICDs. Methods and Results The Prospective Observational Study of Implantable Cardioverter Defibrillators (PROSe-ICD) enrolled 1,189 patients with systolic heart failure who underwent ICD implantation for primary prevention of sudden cardiac death. The primary endpoint was an ICD shock for adjudicated ventricular tachyarrhythmia. The secondary endpoint was all-cause mortality. After a median follow-up of 4.0 years, 137 subjects experienced an appropriate ICD shock and 343 participants died (incidence rates of 3.2 and 5.8 per 100 person-years, respectively). In multivariable adjusted models, higher interleukin-6 (IL-6) levels increased the risk of appropriate ICD shocks. In contrast, C-reactive protein, IL-6, tumor necrosis factor-α receptor II, pro-brain natriuretic peptide, and cardiac troponin T showed significant linear trends for increased risk of all-cause mortality across quartiles. A score combining these 5 biomarkers identified patients who were much more likely to die than to receive an appropriate shock from the ICD. Conclusions An increase in serum biomarkers of inflammation, neurohumoral activation and myocardial injury increased the risk for death but poorly predicted the likelihood of an ICD shock. These findings highlight the potential importance of serum-based biomarkers in identifying patients who are unlikely to benefit from primary prevention ICDs. PMID:25273351

  1. Sexual concerns and practices after ICD implantation

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Elleman-Jensen, Line; Zwisler, Ann-Dorthe;

    2013-01-01

    given about sexual activity, (b) the areas of patient concerns related to sexual function and the ICD, and (c) changes in sexual behavior.Methods:A randomized controlled trial including 196 patients (1:1) was designed, including 12 weeks of exercise training and 1 year of psycho-educational follow......Background:Studies show that patients with implantable cardioverter defibrillators (ICD) frequently experience sexual dysfunction. These experiences are often linked to exercise intolerance, side-effects of medication, and psychological problems.Objective:To describe (a) the level of information......-up focusing on modifiable factors associated with poor outcomes, including sexual functioning. The Sex After ICD Survey was administered 6 months after the randomization as part of the planned explorative outcomes. 141 patients responded.Results:The analyses showed that 37 of the 69 (55.2%) patients...

  2. Painless Implanted Cardioverter Defibrillator Therapy: Have We Taken It Seriously?%植入式心脏复律除颤器的无痛性治疗:我们重视了吗?

    Institute of Scientific and Technical Information of China (English)

    宿燕岗

    2011-01-01

    Shocking therapy of implanted cardioverter defibrillator (ICD) has been criticized for its causing myocardium damage and inducing electrical storm. Instead the anti-tachycardia pacing (ATP) function has been introduced as the main pain-free therapy of ICD, which could terminate about 3/4 ventricular tachycardia ( VT) events, without raising the risk of syncope or accelerated VT. The main concerns of ATP include differential identification of supraventricular tachycardia, re-confirmation of charging, settings of fast VT zone, strategies for optimization, and ATP while or before charging etc. , and the parameters should be adjusted individually during follow up. More concern should be paid to pain-free ICD therapy in clinical practice.%电击治疗可导致包括心肌损伤及诱发植入式心脏复律除颤器电风暴等弊端.植入式心脏复律除颤器的无痛性治疗主要是指其抗心动过速起搏功能.抗心动过速起搏能成功终止约3/4的室性心动过速事件,不增加晕厥或加速室性心动过速.无痛性治疗的主要策略包括室上性心动过速的鉴别程序、充电时的再确认、设定快速室性心动过速区、抗心动过速起搏策略优化、充电中和充电前抗心动过速起搏等.这些参数设置应个体化并在随访中进行调整.应重视植入式心脏复律除颤器无痛性治疗在临床上的应用.

  3. Adding the implantable cardioverter-defibrillator to cardiac resynchronization therapy is associated with improved long-term survival in ischaemic, but not in non-ischaemic cardiomyopathy

    DEFF Research Database (Denmark)

    Witt, Christoffer Tobias; Kronborg, Mads Brix; Nohr, Ellen Aagaard;

    2015-01-01

    Hospital, Denmark from 2000 to 2010 were included. Baseline characteristics were retrieved from patient files and survival data were obtained from the Danish Civil Registration System. The primary outcome was all-cause mortality. The effect of ICD backup was estimated using Cox proportional hazards model...... to ischaemic cardiomyopathy (ICM) or non-ischaemic cardiomyopathy (NICM) treated with a CRT device with or without defibrillator backup. METHODS AND RESULTS: In this observational study, consecutive patients with an ejection fraction ≤35% and QRS width ≥120 ms receiving a CRT device at Aarhus University...

  4. A Young Man Presenting with Pleuritic Chest Pain and Fever after Electrophysiological Study and Implantable Cardioverter-Defibrillator Placement: Diagnostic Difficulties and Value of Bedside Thoracic Sonography.

    Science.gov (United States)

    Faraone, Antonio; Fortini, Alberto

    2015-01-01

    We describe the case of a 23-year-old man presenting with recurrent pleuritic chest pain and prolonged fever after electrophysiology testing and placement of an implantable cardioverter-defibrillator because of a suspected arrhythmogenic right ventricular dysplasia. The clinical suspicion was initially directed toward pneumonia with pleural effusion and later toward an infection of the cardiac device complicated by septic pulmonary embolism. The definitive diagnosis of pulmonary embolism and infarction was suggested by a point-of-care thoracic sonography, performed at the bedside by a clinician caring for the patient, and then confirmed by contrast enhanced computed tomography, which also showed thrombosis of the left iliofemoral vein, site of percutaneous puncture for cardiac catheterization. Prolonged fever was attributable to a concomitant Epstein-Barr virus primary infection that acted as confounding factor. The present report confirms the value of bedside thoracic sonography in the diagnostic evaluation of patients with nonspecific respiratory symptoms.

  5. A Young Man Presenting with Pleuritic Chest Pain and Fever after Electrophysiological Study and Implantable Cardioverter-Defibrillator Placement: Diagnostic Difficulties and Value of Bedside Thoracic Sonography

    Directory of Open Access Journals (Sweden)

    Antonio Faraone

    2015-01-01

    Full Text Available We describe the case of a 23-year-old man presenting with recurrent pleuritic chest pain and prolonged fever after electrophysiology testing and placement of an implantable cardioverter-defibrillator because of a suspected arrhythmogenic right ventricular dysplasia. The clinical suspicion was initially directed toward pneumonia with pleural effusion and later toward an infection of the cardiac device complicated by septic pulmonary embolism. The definitive diagnosis of pulmonary embolism and infarction was suggested by a point-of-care thoracic sonography, performed at the bedside by a clinician caring for the patient, and then confirmed by contrast enhanced computed tomography, which also showed thrombosis of the left iliofemoral vein, site of percutaneous puncture for cardiac catheterization. Prolonged fever was attributable to a concomitant Epstein-Barr virus primary infection that acted as confounding factor. The present report confirms the value of bedside thoracic sonography in the diagnostic evaluation of patients with nonspecific respiratory symptoms.

  6. Statins Decrease Oxidative Stress and ICD Therapies

    Directory of Open Access Journals (Sweden)

    Heather L. Bloom

    2010-01-01

    Full Text Available Recent studies demonstrate that statins decrease ventricular arrhythmias in internal cardioverter defibrillator (ICD patients. The mechanism is unknown, but evidence links increased inflammatory and oxidative states with increased arrhythmias. We hypothesized that statin use decreases oxidation. Methods. 304 subjects with ICDs were surveyed for ventricular arrhythmia. Blood was analyzed for derivatives of reactive oxygen species (DROMs and interleukin-6 (IL-6. Results. Subjects included 252 (83% men, 58% on statins, 20% had ventricular arrhythmias. Average age was 63 years and ejection fraction (EF 20%. ICD implant duration was 29 ± 27 months. Use of statins correlated with lower ICD events (r=0.12, P=.02. Subjects on statins had lower hsCRP (5.2 versus 6.3; P=.05 and DROM levels (373 versus 397; P=.03. Other factors, including IL-6 and EF did not differ between statin and nonstatin use, nor did beta-blocker or antiarrhythmic use. Multivariate cross-correlation analysis demonstrated that DROMs, statins, IL-6 and EF were strongly associated with ICD events. Multivariate regression shows DROMs to be the dominant predictor. Conclusion. ICD event rate correlates with DROMs, a measure of lipid peroxides. Use of statins is associated with reduced DROMs and fewer ICD events, suggesting that statins exert their effect through reducing oxidation.

  7. Defibrillator Implantation in Patients with Nonischemic Systolic Heart Failure

    DEFF Research Database (Denmark)

    Køber, Lars; Thune, Jens J; Nielsen, Jens C;

    2016-01-01

    to coronary artery disease has been based primarily on subgroup analyses. The management of heart failure has improved since the landmark ICD trials, and many patients now receive cardiac resynchronization therapy (CRT). Methods In a randomized, controlled trial, 556 patients with symptomatic systolic heart......Background The benefit of an implantable cardioverter-defibrillator (ICD) in patients with symptomatic systolic heart failure caused by coronary artery disease has been well documented. However, the evidence for a benefit of prophylactic ICDs in patients with systolic heart failure that is not due...... failure (left ventricular ejection fraction, ≤35%) not caused by coronary artery disease were assigned to receive an ICD, and 560 patients were assigned to receive usual clinical care (control group). In both groups, 58% of the patients received CRT. The primary outcome of the trial was death from any...

  8. The association between biventricular pacing and cardiac resynchronization therapy-defibrillator efficacy when compared with implantable cardioverter defibrillator on outcomes and reverse remodelling

    DEFF Research Database (Denmark)

    Ruwald, Anne-Christine; Kutyifa, Valentina; Ruwald, Martin H;

    2015-01-01

    : Using Kaplan-Meier plots, we estimated the threshold of BIV pacing percentage needed for CRT-D to be superior to ICD on the end-point of heart failure (HF) or death in 1219 left bundle branch block (LBBB) patients in the MADIT-CRT trial. Patients were censored at the time of crossover. In multivariable...

  9. Anxiety Predicts Mortality in ICD Patients

    DEFF Research Database (Denmark)

    Kikkenborg Berg, Selina; Caspar Thygesen, Lau; Hastrup Svendsen, Jesper

    2014-01-01

    BACKGROUND: Although highly effective in preventing arrhythmic death, patients receiving an implantable cardioverter defibrillator (ICD) may still experience psychological difficulties such as anxiety, depression, and reduced quality of life. The objectives of this study were to describe patient...... receiving ICD between January 1, 2011 and June 30, 2011 (n = 499). The following instruments were used: SF-36, Hospital Anxiety and Depression Scale, HeartQoL, EQ-5D, and the Multidimensional Fatigue Inventory. RESULTS: The response rate was 72%. Mean age was 65.5 years and 82% patients were males. Fifty...... of perceived health, quality of life, and fatigue; for example, physical health 39.8 versus 44.3 points, compared to secondary prevention indication. Anxiety, poor perceived health, fatigue, and low quality of life were all predictors of mortality, anxiety being the strongest with an adjusted odds ratio of 4...

  10. The Entirely Subcutaneous Defibrillator – A New Generation and Future Expectations

    Science.gov (United States)

    Ali, Hussam; Lupo, Pierpaolo; Cappato, Riccardo

    2015-01-01

    Although conventional implantable cardioverter-defibrillators (ICDs) have proved effective in the prevention of sudden cardiac death (SCD), they still appear to be limited by non-trivial acute and long-term complications. The recent advent of an entirely subcutaneous ICD (S-ICD) represents a further step in the evolution of defibrillation technology towards a less-invasive approach. This review highlights some historical and current issues concerning the S-ICD that may offer a viable therapeutic option in selected patients at high risk of SCD and in whom pacing is not required. After the CE Mark and US Food and Drug Administration (FDA) approvals, the S-ICD is being implanted worldwide with growing clinical data regarding its safety and efficacy (the EFFORTLESS Registry). The recently developed new generation of S-ICD (EMBLEM, Boston Scientific) demonstrates favourable features including a smaller device, longer longevity and remote-monitoring compatibility. Further innovations in the S-ICD system and potential integration with leadless pacing may play an important role in defibrillation therapy and prevention of SCD in the near future. PMID:26835112

  11. Slow ventricular tachycardia in patients with implantable cardioverter defibrillator%植入植入型心律转复除颤器后慢频率室性心动过速的治疗策略

    Institute of Scientific and Technical Information of China (English)

    孙国建; 何浪; 陈宇宁; 欣明花; 付蕾; 钟诚; 沈法荣

    2016-01-01

    Objective This study aims to assess the incidence of slow ventricular tachycardia ( VT ) and its treatment strategies in implantable cardioverter defibrillator( ICD) patients. Methods All 353 patients with including single and dual-chamber ICD or cardiac resyncronization therapy defibrillator( CRT-D) were en-rolled in this study in Zhejiang Greentown Cardiovascular Hospital from January 2008 to December 2014. Pa-tients had a 3-zone detection configuration: monitoring non treatment(ventricular rate 120 to 180 bpm),anti-tachyarrhythmia pacing(ATP)-low energy shock zone(ventricular rate 180 to 200 bpm),and a ventricular fi-brillation zone.When VT burden was more than 10% and the ventricular rate was less than 160 bpm it needed to optimize the parameters to treat the slow VT. Patients were divided into group A ATP-low energy cardioverter groups(ATP1time-5 J-10 J-maximum energy shock);group B ATP-high energy(ATP 3 times-20 J-the largest energy). Results VT occurred in 102(29%)patients,slow VT occurred in 46(13.1%)patients.Parameters optimization was carried for slow VTs in 27(7. 6%)patients.One time ATP therapy success rate was 67% in group A,ATP+5 J success rate was 79%,ATP+5 J+10 J was 92%. Group B 3 times ATP success rate was 71%,ATP 3 times+20 J was 89%. Conclusion The slow VT had a high incidence in patients with ICD,espe-cially in patients who took up large doses of amiodarone andβreceptor blockers.For patients with heavier bur-den of slow VTs,ATP and small energy electric shock therapy may have greater benefit.%目的:探讨慢频率室性心动过速(室速)在植入植入型心律转复除颤器( ICD)患者中的发生率及治疗策略。方法入选浙江绿城心血管病医院心内科自2008年1月至2014年12月植入的除颤器[单、双腔ICD及心脏再同步治疗除颤器( CRT-D)]患者353例。所有一级预防和二级预防患者按既定不同方案设置参数。术后室速发作负荷≥10%且频率<160次/min定义为需优化参数治

  12. A priori expectancy bias and its relation to shock experience and anxiety: a naturalistic study in patients with an automatic implantable cardioverter defibrillator.

    Science.gov (United States)

    Pauli, P; Wiedemann, G; Dengler, W; Kühlkamp, V

    2001-09-01

    Patients with an automatic implantable cardioverter defibrillator (AICD) may offer an unique naturalistic opportunity to study whether expectancy biases develop because of precipitating aversive or traumatic experiences and/or because of elevated anxiety. An expectancy bias and its associations with AICD discharge and anxiety was examined in 24 AICD patients with a thought experiment. While patients without AICD discharge exhibited no expectancy bias, patients with discharge experiences were found to expect that stimuli depicting medical emergency situations will be followed by an aversive consequence. The magnitude of their expectancy bias was positively correlated with their anxiety level. In the group with AICD discharge, patients with low anxiety levels exhibited no bias, while patients with high anxiety levels exhibited a rather strong bias. It seems that the experience of an aversive or traumatic event, here an AICD discharge, is a necessary (but not sufficient) precipitating event for the development of an expectancy bias. If such an event happens, trait anxiety level presumably determines if and how strong the expectancy bias will be.

  13. Psychometric analysis of the Patient Health Questionnaire in Danish patients with an implantable cardioverter defibrillator (The DEFIB-WOMEN study)

    DEFF Research Database (Denmark)

    Pedersen, Susanne S; Mathiasen, Kim; Christensen, Karl Bang;

    2016-01-01

    . The unidimensionality and the precision of the rescored PHQ-9 were confirmed. Items did not have any differential functioning (DIF) across educational level, age, indication for ICD implantation, and severity of heart failure that influence depression outcomes in patients with an ICD. One item exhibited DIF by gender....... Three items did not fit the partial credit model, but the generalized partial credit model could be fitted to the full item set. CONCLUSION: The unidimensionality and reliability of the Danish version of the PHQ-9 were confirmed. However, the associated consequences of the number of response options (3...

  14. Risk of pacemaker or implantable cardioverter defibrillator after radiotherapy for early-stage breast cancer in Denmark, 1982-2005

    DEFF Research Database (Denmark)

    Rehammar, Jens Christian; Johansen, Jens Brock; Jensen, Maj-Britt;

    2016-01-01

    (RT). MATERIAL AND METHODS: All women treated for early-stage BC in Denmark from 1982 to 2005 were identified from the Danish Breast Cancer Cooperative Group. By record linkage to the Danish Pacemaker and ICD Registry information was retrieved on CIED implants subsequent to RT. Standardized incidence...

  15. Implantable cardioverter defibrillator therapy for primary prevention of sudden cardiac death in patients with heart failure%植入型心律转复除颤器在心力衰竭心脏性猝死一级预防中的作用初步观察

    Institute of Scientific and Technical Information of China (English)

    陈太波; 程康安; 高鹏; 刘博江; 范静波; 方全

    2010-01-01

    目的 总结我院应用植入型心律转复除颤器(ICD)进行心力衰竭心脏性猝死(SCD)一级预防的初步经验.方法 入选我院近3年因严重心力衰竭植入ICD进行SCD一级预防的患者,术后3个月进行ICD常规随访,以后每6个月随访1次.结果 入选患者22例,其中单腔ICD 15台,双腔ICD7台.22例患者随访时间3~28个月.记录ICD治疗事件21次,包括12次抗心动过速起搏(ATP)治疗和9次放电,只有1次ATP治疗患者具自觉症状.其中正确治疗(appropriate therapy)11次(52%)包括8次ATP治疗和3次放电,误治疗(inappropriate therapy)10次(48%).发生误治疗患者均为植入单腔ICD.结论 ICD可以安全有效地应用于心力衰竭SCD的一级预防,ICD误治疗事件是值得重视的临床问题,合理的ATP治疗可以提高患者的生活质量.%Objective To evaluate the effectiveness of implantable cardioverter defibrillator (ICD) therapy for primary prevention of sudden cardiac death (SCD) in patients with heart failure. Methods Twen-ty-two consecutive heart failure patients implanted with ICD for primary prevention of SCD in last 3 years were enrolled and followed up 3 months after implantation and every 6 months afterwards. Results Totally 22 cases were enrolled, including 15 with single-chamber ICD and 7 with dual-chamber ICD. Twenty-one ICD therapy events were documented during 3~28 months follow-up period, including 12 anti-tachycardia pacing (ATP) therapies and 9 shocks, and only one had symptoms. Eleven therapies (52%, 8 ATP therapies and 3 shocks) were classified as appropriate, and 10 (48%) as inappropriate. All inappropriate therapies were occurred in pa-tients implanted with single-chamber ICD. Conclusion In heart failure patients ICD for primary prevention of SCD was effective and appropriate. Relatively high incidence of inappropriate therapies remains a challenge. ATP therapy may improve the quality of life in ICD patients.

  16. Incidence of ineffective safety margin testing (J) and efficacy of routine subcutaneous array insertion during implantable cardioverter defibrillator implantation.

    Science.gov (United States)

    Ohlow, Marc-Alexander; Roos, Marcus; Lauer, Bernward; Geller, J Christoph

    2016-01-01

    The purpose of this study was to assess (1) the incidence of safety margin testing J (SMT) and (2) the efficacy/safety of routinely adding a subcutaneous array (SQA) (Medtronic 6996SQ) for these patients. Patients with SMT smaller than a 10-J safety margin from maximum output were considered to have very high readings and underwent SQA insertion. These patients were compared with the rest of the patients who had acceptable SMT (≥10 J). A total of 616 patients underwent ICD implantation during the analysis period. Of those, 16 (2.6%) had SMT J. By univariate analysis, younger age, and non-ischemic cardiomyopathy, were all significant predictors of SMT J (p J; p J occur in about 2.6% of patients undergoing ICD implantation. SQA insertion corrects this problem without procedural/mid-term complications.

  17. Prophylactic left thoracic sympathectomy to prevent electrical storms in CPVT patients needing ICD placement.

    Science.gov (United States)

    Moray, Amol; Kirk, Edwin P; Grant, Peter; Camphausen, Christoph

    2011-11-01

    Catecholaminergic Polymorphic Ventricular Tachycardia (CPVT), a life threatening arrhythmia induced by sympathetic stimulation in susceptible individuals is often refractory to antiarrhythmic agents. First line of treatment, beta-blockers can be ineffective in up to 50% with implantable cardioverter-defibrillator (ICD) placement for refractory cases. Paradoxically ICD can be arryhthmogenic from shock-associated sympathetic stimulation, initiating more shocks and "electrical storms". This has led to the use of more effective beta blockade offered by left sympathectomy, now performed by minimally invasive video assisted thoracoscopic surgery (VATS). Sympathectomy has been traditionally performed long after ICD placement, after the patient has experienced multiple shocks, thus necessitating two procedures. We report simultaneous ICD insertion and thoracoscopic sympathectomy in a 10 year-old boy with CPVT, and suggest it as a better approach than sequential procedures. To our knowledge this is first such reported case.

  18. Combined etiology of anaphylactic cardiogenic shock: Amiodarone, epinephrine, cardioverter defibrillator, left ventricular assist devices and the Kounis syndrome

    Directory of Open Access Journals (Sweden)

    Nicholas G Kounis

    2015-01-01

    Full Text Available Anaphylactic shock is a life-threatening condition which needs detailed and mediculous clinical assessment and thoughtful treatment. Several causes can join forces in order to degranulate mast cells. Amiodarone which is an iodine-containing highly lipophilic benzofuran can induce allergic reactions and anaphylactic shock in sensitized patients. Epinephrine is a life saving drug, but in sulfite allergic patients it should be given with caution due its metabisulfite preservative. Metals covering cardiac defibrillators and pacemakers can act as antigens attached to serum proteins and induce allergic reactions. In anaphylactic shock, myocardial involvement due to vasospasm-induced coronary blood flow reduction manifesting as Kounis syndrome should be always considered. Clinically, combined treatment targeting the primary cause of anaphylaxis together with protection of cardiac tissue seems to be of paramount importance.

  19. Custo-efetividade de cardiodesfibriladores implantáveis no Brasil nos setores público e privado Cost-effectiveness of implantable cardioverter defibrillators in Brazil in the public and private sectors

    Directory of Open Access Journals (Sweden)

    Rodrigo Antonini Ribeiro

    2010-10-01

    Full Text Available FUNDAMENTO: Vários ensaios clínicos randomizados demonstraram a efetividade do cardiodesfibrilador implantável (CDI na redução de morte de pacientes com insuficiência cardíaca congestiva (ICC. Estudos de países desenvolvidos já avaliaram a custo-efetividade do CDI, porém as informações não são transferíveis para o Brasil. OBJETIVO: Avaliar a custo-efetividade do CDI em pacientes com ICC sob duas perspectivas: pública e saúde suplementar. MÉTODOS: Um modelo de Markov foi criado para analisar a relação de custo-efetividade incremental (RCEI do CDI, comparado à terapia convencional, em pacientes com ICC. Efetividade foi medida em anos de vida ajustados para qualidade (QALY. Na literatura, buscaram-se dados de efetividade e complicações. Custos foram extraídos das tabelas do SUS e de valores praticados pelos convênios, assim como médias de internações hospitalares. Análises de sensibilidade univariadas foram feitas em todas as variáveis do modelo. RESULTADOS: A RCEI foi de R$ 68.318/QALY no cenário público e R$ 90.942/QALY no privado. Esses valores são superiores aos sugeridos como pontos de corte pela Organização Mundial da Saúde, de três vezes o PIB per capita (R$ 40.545 no Brasil. Variáveis mais influentes na análise de sensibilidade foram: custo do CDI, intervalo de troca do gerador e efetividade do CDI. Em simulação de cenário semelhante ao MADIT-I, as relações foram de R$ 23.739/QALY no cenário público e R$ 33.592/QALY no privado. CONCLUSÃO: Para a população em geral com ICC, a relação de RCEI do CDI, tanto na perspectiva pública como na privada, é elevada. Resultados mais favoráveis ocorrem em pacientes com alto risco de morte súbita.BACKGROUND: Many randomized clinical trials have demonstrated the effectiveness of the implantable cardioverter-defibrillator (ICDs in death reduction of chronic heart failure (CHF patients. Some developed countries studies have evaluated its cost

  20. Relation of symptomatic heart failure and psychological status to persistent depression in patients with implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Hoogwegt, Madelein T; Jordaens, Luc;

    2011-01-01

    .26 to 4.15), cardiac resynchronization therapy (OR 1.92; 95% CI 1.05 to 3.52), New York Heart Association class III-IV (OR 2.47; 95% CI 1.36 to 4.48), diabetes (OR 2.09; 95% CI 1.01 to 4.29), Type D personality (OR 8.30; 95% CI 4.42 to 15.58), high levels of ICD concerns (OR 2.60; 95% CI 1.44 to 1...... Association class III-IV (OR 2.95; 95% CI 1.47 to 5.89), Type D personality (OR 7.98; 95% CI 3.98 to 16.04), and the use of psychotropic medication (OR 2.73; 95% CI 1.27 to 5.84) were independent correlates of persistent depression. In conclusion, symptomatic heart failure, psychological status...

  1. Automatic mode switching of a dual chamber implantable cardioverter-defibrillator induced by a ventricular escape rhythm.

    Science.gov (United States)

    Barold, S Serge; Van Heuverswyn, Frederic; Stroobandt, Roland X

    2013-01-01

    This report describes a form of group beating induced by a St Jude dual chamber ICD which interpreted a ventricular escape rhythm (with retrograde conduction) as premature ventricular complexes (PVC). These pacemaker-defined PVCs activated the atrial pace-PVC algorithm in 2 steps. 1. The postventricular atrial refractory period (PVARP) was terminated upon detecting a retrograde P wave within its unblanked portion, and 2. An atrial stimulus was released 330ms after the end of the PVARP. This response resulted in automatic mode switching because the 330ms interatrial interval was shorter than the atrial tachycardia detection interval. The arrhythmia may be considered to represent an unusual form of pacemaker escape-capture bigeminy.

  2. 全自动远程家庭监测系统在植入心律转复除颤器患者中的应用%Home monitoring in patients with implantable cardioverter defibrillator or cardiac resynchronization therapy defibrillator

    Institute of Scientific and Technical Information of China (English)

    王凤梅; 李述峰; 王帆; 张烁

    2014-01-01

    目的 评价全自动远程家庭监测(HM)在植入心律转复除颤器(ICD)/心脏再同步治疗除颤器(CRT-D)患者中的应用.方法 随访23例植入了带有HM功能的ICD及CRT-D患者,分析HM所获得的日常信息和报警数据,观察其对系统相关事件、心律失常和心力衰竭(心衰)监测在内的临床相关事件的早期监测及临床干预的疗效.结果 对23例患者随访122~937(452.1±262.2)d,共接收报警信息1 991次,发现异常事件1 481次,其中96.4%是临床相关事件,1.5%为系统相关事件,无信息传输事件占2.1%.系统相关事件多为感知异常,其中发现左心室导线脱位1例.临床相关事件中心律失常报警事件占84.7%[室上性心律失常和心房颤动(房颤)事件较多],心衰报警事件占15.3%,以静息时心率升高及心脏再同步治疗心室起搏百分比降低为主.根据HM系统报警信息,电话联络患者65例次,优化参数11例次,指导调整药物治疗方案18例次,4例患者入院治疗.结论 对于植入ICD/CRT-D的患者,HM系统是一项必要的、安全可靠的远程监测方法,可以及时识别起搏系统相关异常、发现临床相关事件,可指导对患者进行早期临床干预,优化随访管理,提高患者生活质量.%Objective To evaluate the benefit of Home monitoring (HM) system in patients with implantable cardioverter defibrillator (ICD) or cardiac resynchronization therapy defibrillator(CRT-D).Methods Twentythree patients undergoing implantation of ICD or CRT-D with HM were enrolled,data automatically collected on a daily basis and alerts by HM were analyzed.Early detection and intervention effect of HM included arrhythmias or heart failure to clinical events and system related events.Results The mean follow-up duration was 122-937 (452.1±262.2) d,a total of 1 991 remote transmissions were received.Among these transmissions,1 481 abnormal events were reported,96.4% of events were clinical-related,and 1.5

  3. Implantable cardioverter defibrillator for primary prevention of sudden cardiac death in the patients with chronic heart failure%植入型心律转复除颤器应用于慢性心力衰竭患者心脏性猝死一级预防的长期随访

    Institute of Scientific and Technical Information of China (English)

    王礼琳; 范洁; 赵金辅; 周启云; 张曦; 丁立群

    2012-01-01

    Objective To evaluate the clinical benefits of implantable cardioverter defibrillator for the primary prevention of sudden cardiac death(SCD) in the patients with chronic heart failure due to either ischemic or nonischemic dilated cardiomyopathy.Methods We retrospectively enrolled 56 patients who were diagnosed with chronic heart failure caused by either ischemic or nonischemic dilated cardiomyopathy from March 2002 to October 2011.Patients were graded NYHA class Ⅱ and Ⅲ,with left ventricular ejection fraction (LVEF) at 0.16 ~ 0.35 (0.29 ± 0.05).All patients voluntarily took standard medicine treatment of chronic heart failure and underwent implantable cardioverter defibrillator (ICD) implantation and initial parameters were set up.All enrolled patients were followed up at 1,3,and 6 months,and every 6 months thereafter.Results ICD was implanted via the subclavian vein successfully in all patients.During the follow-up period of 1 ~ 115 (44.05±35.16) months,11 patients had 26 episodes of ventricular fibrillation(19.6%),which were defibrillated successfully; 17 patients had 39 episodes of ventricular tachycardia(VT,30.4%),which were terminated successfully at 94.8%.Besides,failure of ICD termination of VT occurred in 1 patient for twice and the arrhythmia was self-terminated later.Inadequate shocks were found in 8 patients.Electrical storm occurred in 6 cases.ICD battery was exhausted in 16 patients and 10 patients accepted replacement of ICD.Eight patients died.Conclusions The patients with chronic heart failure due to either ischemic or nonischemic dilated cardiomyopathy are at high risk of SCD.ICD implantation can reduce the risk of SCD for the primary prevention.%目的 对植入型心律转复除颤器(ICD)应用于缺血性或非缺血性心肌病慢性心力衰竭患者心脏性猝死(SCD)一级预防价值进行长期随访观察.方法 2002年3月至2011年10月入选56例缺血性或非缺血性心肌病患者,心功能Ⅱ~Ⅲ级(NYHA

  4. Impacto da parada cardíaca induzida nas funções cognitivas após o implante de cardiodesfibrilador Impacto de la parada cardíaca inducida en las funciones cognitivas después del implante de desfibrilador cardiaco Impact of induced cardiac arrest on cognitive function after implantation of a cardioverter-defibrillator

    Directory of Open Access Journals (Sweden)

    Mauro Prado da Silva

    2009-02-01

    1980 y se considera el tratamiento estándar para individuos bajo el riesgo de desarrollar arritmias ventriculares fatales. Con el interés de garantizar el funcionamiento adecuado del desfibrilador cardiaco, la energía necesaria para el término de la taquicardia ventricular o de la fibrilación ventricular, debe ser determinada durante el implante, siendo este procedimiento llamado test del límite de desfibrilación. Para la realización del test es necesario que se haga la inducción de la fibrilación ventricular, para que el aparato pueda identificar el ritmo cardíaco y tratarlo. El objetivo de este estudio fue verificar la incidencia de disfunción cognitiva 24 horas después del implante del desfibrilador cardiaco. MÉTODO: Se seleccionó una muestra consecutiva de 30 pacientes con indicación de colocación de desfibrilador cardiaco implantable (DCI y 30 pacientes con indicación de implante de marca-paso (MP. Los pacientes fueron evaluados en los siguientes momentos: 24 horas antes de la colocación del DCI o MP con ficha de evaluación preanestésica, Mini-Examen del Estado Mental (MEEM y Confusion Assessment Method (CAM. Durante el implante del DCI o MP fueron medidas las variables: número de paradas cardíacas y tiempo total de parada cardíaca. Veinte y cuatro horas después de la colocación del DCI o MP, se evaluaron las variables: MEEM y CAM. RESULTADOS: El test de Fisher mostró que no había diferencia de la frecuencia de puntuaciones alteradas del MEEM y del CAM entre los grupos antes y después de los implantes. El tiempo promedio de PCR 7,06, con máximos y mínimos de 15,1 y 4,7 segundos. CONCLUSIONES: La inducción de parada cardíaca durante el test del límite de desfibrilación, no conllevó a la disfunción cognitiva veinte y cuatro horas después del implante del desfibrilador cardiaco.BACKGROUND AND OBJECTIVES: Implantable cardioverter-defibrillators (ICD were introduced in clinical practice in 1980 and they are considered the standard

  5. 植入型心律转复除颤器在致心律失常性右心室心肌病患者中的应用%Implantable cardioverter defibrillator therapy in patients with arrhythmogenic right ventricular cardiomyopathy

    Institute of Scientific and Technical Information of China (English)

    孙奇; 陈柯萍; 陈若菡; 戴研; 华伟; 张澍

    2013-01-01

    Objective To evaluate the role of implantable cardioverter defibrillator(ICD) therapy in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC).Methods From Mar.2004 to Mar.2012,ARVC patients received ICD were enrolled in this study,and the clinical characteristics were collected.In the follow-up,we assessed the incidence,feature and ICD therapy in these patients.Results Eighteen patients were enrolled [12 men,6 women,mean age (46.4 ± 13.8) years].During the (46.6 ± 30.5) months followup period,ICD recorded 111 ventricular tachycardia (VT)/ventricular fibrillation (VF) episodes (1 VF,110 VT) in 6 patients.Among these,3 patients experienced 7 electrical storms(ES).Compare to patients without ICD therapy,C-reactive protein(CRP) level was higher in ICD therapy group.Among VT/VF episodes,12 episodes were terminated by shocks,99 episodes were terminated by anti-tachycardia pacing(ATP).Conclusions VT episodes were very common in ARVC patients,most of them could terminated by ATP.Repeated episodes of malignant arrhythmias in ARVC patients with ES were common.CRP level might be a significant predictor of appropriate ICD therapy in ARVC patients.%目的 总结阜外心血管病医院应用植入型心律转复除颤器(ICD)治疗致心律失常性右心室心肌病(ARVC)的经验.方法 入选我院2004年3月至2012年3月确诊并植入ICD的ARVC患者,收集临床资料,进行常规电话及门诊随诊.结果 共18例患者[男12例,女6例,平均年龄(46.4±13.8)岁]入选,平均随访(46.6±30.5)个月,有6例患者出现了111次室性心动过速(VT)/心室颤动(VF)事件,其中仅1次VF事件,其余均为VT事件,其中3例患者术后共出现了7次电风暴.ICD治疗组中的C反应蛋白(CRP)明显高于ICD未治疗组.111次VT/VF事件中,12次经电除颤终止心动过速,其余均通过抗心动过速起搏(ATP)终止了心动过速.结论 ARVC患者ICD植入后的VT/VF事件以VT为主,多数可经ATP终止;出现电风暴的ARVC患者

  6. Biomarker-based diagnosis of pacemaker and implantable cardioverter defibrillator pocket infections: A prospective, multicentre, case-control evaluation

    Science.gov (United States)

    Vrazic, Hrvoje; Haller, Bernhard; Braun, Siegmund; Petzold, Tobias; Ott, Ilka; Lennerz, Agnes; Michel, Jonathan; Blažek, Patrick; Deisenhofer, Isabel; Whittaker, Peter; Kolb, Christof

    2017-01-01

    Background The use of cardiac implantable electronic devices (CIED) has risen steadily, yet the rate of cardiac device infections (CDI) has disproportionately increased. Amongst all cardiac device infections, the pocket infection is the most challenging diagnosis. Therefore, we aimed to improve diagnosis of such pocket infection by identifying relevant biomarkers. Methods We enrolled 25 consecutive patients with invasively and microbiologically confirmed pocket infection. None of the patients had any confounding conditions. Pre-operative levels of 14 biomarkers were compared in infected and control (n = 50) patients. Our selected biomarkers included white blood cell count (WBC), C-reactive protein (CRP), procalcitonin (PCT), lipopolysaccharide binding protein, high-sensitivity C-reactive protein (HS-CRP), polymorphonuclear-elastase, presepsin, various interleukins, tumor necrosis factor α (TNF-α), and granulocyte macrophage colony-stimulating factor (GM-CSF). Results Of the 25 patients with isolated pocket infection (70±13years, 76% male, 40% ICDs), none presented with leukocytosis. In contrast, they had higher serum levels of HS-CRP (p = 0.019) and PCT (p = 0.010) than control patients. Median PCT-level was 0.06 ng/mL (IQR 0.03–0.07 ng/mL) in the study group versus 0.03 ng/mL (IQR 0.02–0.04 ng/mL) in controls. An optimized PCT cut-off value of 0.05 ng/mL suggests pocket infection with a sensitivity of 60% and specificity of 82%. In addition TNF-α- and GM-CSF-levels were lower in the study group. Other biomarkers did not differ between groups. Conclusion Diagnosis of isolated pocket infections requires clinical awareness, physical examination, evaluation of blood cultures and echocardiography assessment. Nevertheless, measurement of PCT- and HS-CRP-levels can aid diagnosis. However, no conclusion can be drawn from normal WBC-values. Clinical trial registration clinicaltrials.gov identifier: NCT01619267 PMID:28264059

  7. Modulatory effects of cognitive behavior therapy on depression and anxiety in patients with implantable cardioverter defibrillator%认知行为疗法对心律转复除颤器植入患者抑郁焦虑症状的调节作用

    Institute of Scientific and Technical Information of China (English)

    祁述善; 方臻飞; 刘启明; 周胜华

    2005-01-01

    BACKGROUND: 60% of the patients receiving implantable cardioverter defibrillator(ICD) believe their quality of life has been improved. However,about 30% to 50% of the patients suffer from postoperative depression and anxiety; especially those patients receive electroconvulsive therapy (ECT).OBJECTIVE: To probe into the modulatory effects of cognitive behavior therapy(CBT) on depression and anxiety in patients with ICD.DESIGN: A retrospective case analysis based on ICD patients SETTING: Room of Cardiac Catheterization, Department of Cardiology, Xiangya Second Hospital PARTICIPANTS: The study was conducted in the Room of Cardiac Catheterization of the Department of Cardiology, Xiangya Second Hospital,Central South University from October 2000 to August 2001. Inclusive criteria: ICD patients that had ineffective medicine therapy for paroxysmal ventricular tachycardia and/or ventricular fibrillation complicated with cardiac syncope. Exclusive criteria: incoorperative patients or patients who unable to receive periodical follow up. A total of 6 patients were involved including 4 male and 2 female patients aged from 45 to 71 years old with an average age of (57.3 ± 2.4) years old. All of the patients received Micro Jewell Ⅱ 7223 ICD made by Medtronic Company. Diagnoses of basic disease:2 cases of coronary heart disease, 2 cases of right ventricular myocardial disease, 1 case of paroxysmal ventricular tachycardia due to unknown reason,and 1 case of Brugada syndrome.METHODS: "Morita therapy" technique was used. Patients were asked to transfer their spirit energies into feasible objectives of their real life, which would be helpful to the rapid improvement of their symptoms. symptom checklist-90(SCL-90) scale was used to evaluate the psychological symptoms before and after the therapy.MAIN OUTCOME MEASURES: Comparison of the scores gained in SCL-90 between before and after CBT.RESULTS: There were significant differences in the items of somatization,compulsion, sensitive

  8. Subcutaneous Implantable Cardioverter-Defibrillator

    Science.gov (United States)

    ... Search Donate Circulation My alerts Sign In Join Facebook Twitter Home About this Journal Editorial Board General Statistics Circulation Doodle → Blip the Doodle Information for Advertisers Author Reprints Commercial Reprints Customer Service and Ordering ...

  9. Optimal tachycardia programming in ICDs : Recommendations in the post-MADIT-RIT era.

    Science.gov (United States)

    Israel, Carsten W; Burmistrava, Tatsiana

    2016-09-01

    Optimal implantable cardioverter-defibrillator (ICD) programming can reduce the incidence of inappropriate shock therapy and improve prognosis in patients with an ICD. Only after results from randomized trials became available was the "safety first" feeling overcome that mandated early shock therapy, waived the use of antitachycardia pacing and forced shock therapy after a time of 30 s expired, even if tachycardia discriminators would have withheld the therapy. The strong evidence to limit ICD therapy to longer ventricular tachycardia (VT) should not result in individually dangerous ICD programming, particularly in patients with a high risk of slow VT (known monomorphic VT, post VT ablation, during treatment with amiodarone, very dilated left ventricle). Monitoring zones may aid to detect unexpected slow VT and to explain symptoms such as presyncope without exposing the patient to an unnecessary risk of inappropriate therapy. This review summarizes our current knowledge on optimal ICD programming and explains exactly how we should program device parameters in practice in single- or dual-chamber ICDs by different manufacturers and in different groups of patients.

  10. Heart Rhythm UK position statement on clinical indications for implantable cardioverter defibrillators in adult patients with familial sudden cardiac death syndromes.

    Science.gov (United States)

    Garratt, Clifford J; Elliott, Perry; Behr, Elijah; Camm, A John; Cowan, Campbell; Cruickshank, Stephanie; Grace, Andrew; Griffith, Michael J; Jolly, Anne; Lambiase, Pier; McKeown, Pascal; O'Callagan, Peter; Stuart, Graham; Watkins, Hugh

    2010-08-01

    Whilst the decision regarding defibrillator implantation in a patient with a familial sudden cardiac death syndrome is likely to be most significant for any particular individual, the clinical decision-making process itself is complex and requires interpretation and extrapolation of information from a number of different sources. This document provides recommendations for adult patients with the congenital Long QT syndromes, Brugada syndrome, catecholaminergic polymorphic ventricular tachycardia, hypertrophic cardiomyopathy, and arrhythmogenic right ventricular cardiomyopathy. Although these specific conditions differ in terms of clinical features and prognosis, it is possible and logical to take an approach to determining a threshold for implantable cardioveter-defibrillator implantation that is common to all of the familial sudden cardiac death syndromes based on estimates of absolute risk of sudden death.

  11. Incidence and causes of inappropriate detection and therapy by implantable defibrillators of cardioversion in patients with ventricular tachyarrhythmia

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Background Implantable cardioverter defibrillator (ICD) is the only effective therapy in patients with life threatening ventricular arrhythmias. Inappropriate detection and therapy by ICDs are the most common causes of side effects that affect the quality of life in ICD recipients. This study evaluated the incidence and causes of inappropriate detection and therapy by ICDs in patients in our hospital.Methods From January 2000 to December 2005, fifty patients who received ICD implantation for ventricular arrhythmias for prevention of sudden cardiac death were evaluated in this study. Each ICD was programmed using clinical arrhythmic and cardiac data of the patient before discharge. Patients were followed up by standard schedule after implantation and all data retrieved from each device were collected and saved for further analysis. Results No arrhythmic event was detected in 12/50 (24%) patients during the period of follow-up. Among the remaining patients, 11 (22%) experienced inappropriate detections and therapies during follow-up in this study. ICD detected 383 ventricular tachyarrhythmia (VT) and 108 ventricular fibrillation (VF) episodes and delivered 678 therapies. In VT group, ICD delivered 413 antitachycardiac pacings (ATPs) and 118 shocks, among which 78 ATPs and 9 shocks were initiated by 55/383 (14.3%) inappropriate detections. In VF group ICD delivered 147 shocks, among which 56 shocks were initiated by 28/108 (26.9%) inappropriate detections. Overall, more than 50% of these episodes were caused by atrial fibrillation (AF) with rapid ventricular response, followed by electromagnetic or myopotential interference. In addition, most inappropriate therapies occurred within one year after ICD implantation.Conclusions About one fifth of patients experienced ICD inappropriate detection and therapy after implantation. The main cause was AF with rapid ventricular response, followed by electromagnetic or myopotential interference.

  12. Reuse of pacemakers, defibrillators and cardiac resynchronisation devices

    Science.gov (United States)

    Sakthivel, R; Satheesh, Santhosh; Ananthakrishna Pillai, Ajith; Sagnol, Pascal; Jouven, Xavier; Dodinot, Bernard; Balachander, Jayaraman

    2017-01-01

    Objective Access to pacemakers remains poor among many patients in low/middle-income countries. Reuse of explanted pacemakers is a possible solution, but is still not widespread because of concerns regarding outcomes, especially infection. Our objective was to study early outcomes with implants using reused devices and compare them with those with implants using new devices. Methods We studied all patients who underwent implantation of a new or reused pacemaker, cardiac resynchronisation therapy (CRT) device or implantable cardioverter defibrillator (ICD) in the last 5 years at a single institution. We analysed outcomes related to infection, device malfunction and device-related death within 6 months after initial implantation. Results During the study period, 887 patients underwent device implant, including 127 CRT devices or ICDs. Of these, 260 devices (29.3%) were reused and the others were new. At 6 months, there were three device-related infections in implants using a new device. There were no infections among patients receiving a reused device. There were no device malfunctions or device-related deaths in either group. Conclusions We found no difference in rate of infection or device malfunction among patients getting a reused device as compared with those with a new device. This study reinforces the safety of reusing devices for implant including CRT and ICDs. PMID:28176981

  13. An ICD Programming Study for Patients with Electrical Storm after Implantation of Implantable Cardioverter Defib-rillator%除颤器植入患者发生心室电风暴慢室速时参数设置的研究

    Institute of Scientific and Technical Information of China (English)

    王召军; 郑蕾; 陈家亮; 曲秀芬; 李晶洁

    2014-01-01

    目的:探讨植入型心律转复除颤器( implantable cardioverter defibrillator, ICD)植入患者发生心室电风暴慢室性心动过速(慢室速,150~180/min)时合理的ICD工作模式的参数设置。方法对我院ICD植入以心室电风暴慢室速急诊入院的11例常规予抗室速药物治疗,慢室速的治疗工作模式均随机选择抗心动过速起搏( ATP)的短阵快速起搏(BURST)5次后不转复即予体内电击(SHOCK)治疗(B5方案)和BURST 1次后不转复即予低能量SHOCK治疗( S1方案)。 B5方案和S1方案,每种方案工作24 h,然后轮换,观察2周内慢室速总发作次数,B5方案和S1方案的总工作次数、复律成功率、室速治疗开始到成功的时间及患者耐受情况。结果本组共记录188 d,其中B5方案、S1方案各94 d。 ICD共检测到慢室速204次,其中室速监测未治疗(VT-monitored)82次(有3次事件在ATP治疗前自行终止),室速监测并治疗122次(治疗应用B5方案65次,S1方案57次)。住院期间无死亡患者,B5方案和S1方案的转复成功率和SHOCK发生率比较差异无统计学意义(P>0.05),但B5方案总ICD治疗时间较S1方案明显增加(P0. 05), but the treatment time was increased in B5 scheme than that in S1 scheme (P <0. 01). Conclusion Patients with ICD implantation during ventricular electrical storm should be pro-grammed individually. Excessive pursuit of ATP painless therapy may increase the risk of heart failure.

  14. Clinical practice of defibrillator implantation after myocardial infarction: impact of implant time: results from the PreSCD II Registry†

    Science.gov (United States)

    Völler, Heinz; Kamke, Wolfram; Klein, Helmut U.; Block, Michael; Reibis, Rona; Treusch, Sven; Contzen, Klaus; Wegscheider, Karl

    2011-01-01

    Aims Current guidelines recommend implantable cardioverter-defibrillator (ICD) therapy for primary prevention of sudden cardiac death in patients with the reduced left ventricular function (LVEF ≤30%) not earlier than 40 days after myocardial infarction (MI). The aim of the prospective Prevention of Sudden Cardiac Death II (PreSCD II) registry was to investigate the clinical practice of ICD therapy in post-MI patients and to assess the impact on survival. Methods and results 10 612 consecutive patients (61 ± 12 years, 76% male) were enrolled 4 weeks or later after MI in 19 cardiac rehabilitation centres in Germany from December 2002 to May 2005. All patients with left ventricular ejection fraction (LVEF) ≤40% (n = 952) together with a randomly selected group of patients with preserved left ventricular function (n = 1106) were followed for 36 months. Cox proportional hazard models were used to correlate ICD implantation and survival with baseline characteristics. Of all patients studied, 75.9% were enrolled within 4–8 weeks, 10.7% more than 1 year after MI. Pre-specified Group 1 with an LVEF ≤30% consisted of 269 patients (2.5%), Group 2 with LVEF 31–40% of 727 patients (6.9%), and Group 3 with LVEF >40% of 1148 randomly selected patients from the cohort of 9616 patients with preserved LV function. After 36 months, only 142 patients (6.9%) had received an ICD; 82 (31.7%) of Group 1, 49 (7%) of Group 2, and 11 (1%) in Group 3. The ICD was implanted in 47% of all patients within 1 year after their index MI. Implantable cardioverter-defibrillator patients were predominantly characterized by low ejection fraction, but also by several other independent risk factors. Patients who received an ICD had an adjusted 44% lower mortality (hazard ratio 0.56, 95% confidence intervals 0.32–1.01; P = 0.053) than comparable patients without ICD therapy. All cause mortality of ICD recipients was significantly lower if the ICD was implanted later than 11 months after acute

  15. Implantable defibrillator lead extraction with optimized standard extraction techniques

    Institute of Scientific and Technical Information of China (English)

    Xian-Ming Chu; Xue-Bin Li; Ping Zhang; Yi An; Jiang-Bo Duan; Long Wang; Ding Li; Bing Li; Ji-Hong Guo

    2013-01-01

    Background Implantable cardioverter-defibrillator (ICD) leads might not be extracted especially in developing countries because of the high cost and lack of specialized tools. We aimed to evaluate transvenous extraction of ICD leads using optimized standard techniques. Methods We prospectively analyzed clinical characteristics, optimized extraction techniques and the feasibility of extraction for 40 patients (33 males; mean age 47.9 ± 16.1 years) with 42 ICD leads. Results Complete procedural success rate was 95.2% (40/42), and the clinical success rate was 97.6% (41/42). One ICD lead required cardiothoracic surgery. Minor complications occurred in three cases (7.5%), and no major complications or death occurred. Locking stylets were used to extract most leads (34, 81.0%) and almost half of the leads (20, 47.6%) required mechanical dilatation to free fibrotic adhesions; these leads had been implanted for a longer period of time than the others (43.7 ± 18.2 vs. 18.4 ± 13.4 months, P < 0.05). Three-quarters of the leads (30, 71.4%) were extracted with locking stylets plus manual traction (12, 28.6%), or mechanical dilatation with counter-traction (18, 42.8%) by the superior vena cava approach and one-quarter of the leads (11, per lead. Linear regression analysis showed that the extraction time was significantly correlated with implant duration (r = 0.70, P < 0.001). optimized procedure for transvenous extraction of ICD leads provides a practical and low-cost method for standard procedures.

  16. Physical Activity in Primary Versus Secondary Prevention Indication Implantable Cardioverter Defibrillator Recipients 6–12 Months After Implantation – A Cross-Sectional Study With Register Follow Up

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Thygesen, Lau Caspar; Svendsen, Jesper Hastrup

    2015-01-01

    outcomes; to describe patients' beliefs regarding participation in physical exercise by ICD indication; to describe factors predicting low physical activity; and to describe physical activity as a predictor of mortality. DESIGN: National survey with register follow-up. Comparisons were made to a matched......, with 82% of participants being men. Of the participants, 37% participated in a rehabilitation program, and 21% were sedentary compared with 8% in the reference population (Pphysical exercise guidelines. Low physical activity was predicted by primary prevention...... indication (odds ratio [OR]=2.5; 95% confidence interval [CI], 1.3-4.7) and higher comorbidity (OR=2.1; 95% CI, 1.0-4.1; Pphysical activity was associated with increased mortality (OR=3.9; 95% CI, 1.11-13.71; Psex...

  17. Evaluation and Management of Patients After Implantable Cardioverter-Defibrillator Shock%植入型心律转复除颤器放电后患者的诊治

    Institute of Scientific and Technical Information of China (English)

    Anil K. Gehi; Davendra Mehta; J. Anthony Gomes; 樊颖婕

    2007-01-01

    背景:多项大规模临床试验表明,植入型心律转复除颤器(implantable cardioverterdefibrillator,ICD)能够有效降低部分心脏病患者的死亡率.此后,ICD的植入量大幅增加,非电生理专科医生也因此经常会遇到实施ICD电转复除颤的患者.目的:在接受ICD电转复除颤的患者中评估诊疗策略.证据获取:采用下列医学主题词在PubMed和MEDLINE数据库中检索1990年1月至2006年9月发表的文献:defibrillators,implantable(除颤器,植入型);defibrillators,implantable/adverse effects(除颤器,植入型/不良反应);抗心律失常药物(anti-arrhythmic agents);电除颤(electric countershock);生活质量(quality of life);心动过速治疗(tachycardia therapy);运算法则(algorithm);室性心动过速/诊断(ventricular tachycardia/diagnosis);室上性心动过速/诊断(supraventricular tachycardia/diagnosis).排除病例报告,仅纳入英文文献.参考美国心脏病学会(American College of Cardiology)、美国心脏协会(American Heart Association)、心脏节律学会(Heart Rhythm Society)发布的建议、指南及所附参考文献,获得其他相关文献.证据综合:ICD恰当放电和误放电均有诸多原因.误放电可严重影响患者的生活质量.目前有多种ICD程控技术可有效控制ICD恰当放电和误放电的发生.采用抗心律失常药也能有效减少放电频率.结论:采用有效的ICD程控和抗心律失常药物可在保障ICD急救功能的同时减少ICD放电.对现有各种治疗手段有一个基本的了解是诊治接受ICD放电者的基础.

  18. Renal infarction due to atrial fibrillation after implantation of implantable cardioverter-defibrillator:a case report and review of literature%心房颤动患者植入植入式心脏复律除颤器术后肾梗死1例及文献复习

    Institute of Scientific and Technical Information of China (English)

    黄樱硕; 孙颖; 邢云利; 王翠英; 黄蔚; 李清清; 吴永全; 马清

    2014-01-01

    1例合并阵发性心房颤动(AF)的老年女性因室性心动过速(VT)而植入植入式心脏复律除颤器(ICD),围术期为避免出血风险,未予抗凝治疗,术后7d出现发热、腹痛,完善检查后诊断为肾梗死,立即开始规律抗凝治疗。目前针对AF患者植入心脏节律装置(CRD)围术期不同抗凝策略的安全性及有效性仍有争议。AF患者合并肾梗死相对少见,且该患者临床表现不典型,增加了早期诊断的难度。该病例带给我们的启示是:(1)对于卒中高危的AF患者,在植入CRD的围术期,抗凝治疗是必要的,但是采用何种抗凝策略尚有争议;(2)对于卒中高危的AF患者,在无抗凝的情况下,出现急腹症等表现时,应考虑腹腔脏器急性栓塞梗死的可能性。%We reported an elderly female (76 years old) accompanied with paroxysmal atrial fibrillation (AF) who underwent the implantation of implantable cardioverter-defibrillator (ICD) due to ventricular tachycardia (VT) in our department. No peri-operative anticoagulation was given to her in consideration of risk for hemorrhage. The patient was found to have fever and abdominal pain at the 7th day after surgery, and then right renal infarction was confirmed after diagnosis. Then the patient was given standard anticoagulant therapy. In present, it is a controversial issue on the efficacy and safety of anticoagulation strategy during perioperation of implantation of cardiac rhythm device (CRD). Renal infarction due to AF is relatively rare and the atypical clinical manifestations make early diagnosis for this patient more difficult. The revelation of this case includes:for patients with AF and high risk of stroke, anticoagulation therapy is necessary, but the strategy of anticoagulation remains controversial;for patients with AF and moderate risk of stroke, acute embolic infarction of abdominal organs should be taken into account when acute abdominal

  19. Infarct size and recurrence of ventricular arrhythmias after defibrillator implantation

    Energy Technology Data Exchange (ETDEWEB)

    Sutter, J. de; Tavernier, R.; Kazmierckzak, J.; Buyzere, M. de; Clement, D.L. [Department of Cardiology, University Hospital Gent, Gent (Belgium); Wiele, C. van de; Dierckx, R.A. [Department of Nuclear Medicine, University Hospital Gent (Belgium); Jordaens, L. [Thoraxcenter, University Hospital Rotterdam-Dijkzigt (Netherlands)

    2000-07-01

    Infarct size as determined by perfusion imaging is an independent predictor of mortality after implantable cardioverter defibrillator (ICD) implantation in patients with coronary artery disease (CAD) and life-threatening ventricular arrhythmias (VA). However, its value as a predictor of VA recurrence and hospitalisation after ICD implantation is unknown. Therefore, the objective of this study was to evaluate whether infarct size as determined by perfusion imaging can help to identify patients who are at high risk for recurrence of VA and hospitalisation after ICD implantation. We studied 56 patients with CAD and life-threatening VA. Before ICD implantation, all patients underwent a uniform study protocol including a thallium-201 stress-redistribution perfusion study. A defect score as a measurement of infarct size was calculated using a 17-segment 5-point scoring system. Study endpoints during follow-up were documented episodes of appropriate anti-tachycardia pacing and/or shocks for VA and cardiac hospitalisation for electrical storm (defined as three or more appropriate ICD interventions within 24 h), heart failure or angina. After a mean follow-up of 470{+-}308 days, 22 patients (39%) had recurrences of VA. In univariate analysis, predictors for recurrence were: (a) ventricular tachycardia (VT) as the initial presenting arrhythmia (86% vs 59% for patients without ICD therapy, P=0.04), (b) treatment with {beta}-blockers (36% vs 68%, P=0.03) and (c) a defect score (DS) {>=}20 (64% vs 32%, P=0.03). In multivariate analysis, VT as the presenting arrhythmia ({chi}2=5.51, P=0.02) and a DS {>=}20 ({chi}2=4.22, P=0.04) remained independent predictors. Cardiac hospitalisation was more frequent in patients with a DS {>=}20 (44% vs 13% for patients with DS <20, P=0.015) and this was particularly due to more frequent hospitalisations for electrical storm (24% vs 3% for patients with DS<20, P=0.037). The extent of scarring determined by perfusion imaging can separate

  20. A study to improve communication between clinicians and patients with advanced heart failure: methods and challenges behind the working to improve discussions about defibrillator management trial.

    Science.gov (United States)

    Goldstein, Nathan E; Kalman, Jill; Kutner, Jean S; Fromme, Erik K; Hutchinson, Mathew D; Lipman, Hannah I; Matlock, Daniel D; Swetz, Keith M; Lampert, Rachel; Herasme, Omarys; Morrison, R Sean

    2014-12-01

    We report the challenges of the Working to Improve Discussions About Defibrillator Management trial, our novel, multicenter trial aimed at improving communication between cardiology clinicians and their patients with advanced heart failure (HF) who have implantable cardioverter defibrillators (ICDs). The study objectives are (1) to increase ICD deactivation conversations, (2) to increase the number of ICDs deactivated, and (3) to improve psychological outcomes in bereaved caregivers. The unit of randomization is the hospital, the intervention is aimed at HF clinicians, and the patient and caregiver are the units of analysis. Three hospitals were randomized to usual care and three to intervention. The intervention consists of an interactive educational session, clinician reminders, and individualized feedback. We enroll patients with advanced HF and their caregivers, and then we regularly survey them to evaluate whether the intervention has improved communication between them and their HF providers. We encountered three implementation barriers. First, there were institutional review board concerns at two sites because of the palliative nature of the study. Second, we had difficulty in creating entry criteria that accurately identified an HF population at high risk of dying. Third, we had to adapt our entry criteria to the changing landscape of ventricular assist devices and cardiac transplant eligibility. Here we present our novel solutions to the difficulties we encountered. Our work has the ability to enhance conduct of future studies focusing on improving care for patients with advanced illness.

  1. [The clinical practice guidelines of the Sociedad Española de Cardiología on the automatic implantable defibrillator].

    Science.gov (United States)

    Pérez-Villacastín, J; Carmona Salinas, J R; Hernández Madrid, A; Marín Huerta, E; Merino Llorens, J L; Ormaetxe Merodio, J; Moya i Mitjans, A

    1999-12-01

    Since the first implantation in man in 1980 implantable cardioverter defibrillator technology has greatly improved and the number of devices implanted has increased considerably every year. Non thoracotomy lead systems and biphasic shocks are now the approach of choice, offering an almost 100% success rate. This document reviews the recommendations for qualification of personnel and for the centres implanting and carrying out follow-ups on defibrillators. The current indications for the implantation of implantable cardioverter defibrillator are also addressed.

  2. Management of radiation oncology patients with a pacemaker or ICD : A new comprehensive practical guideline in The Netherlands

    NARCIS (Netherlands)

    Hurkmans, Coen W.; Knegjens, Joost L.; Oei, Bing S.; Maas, Ad J. J.; Uiterwaal, G. J.; van der Borden, Arnoud J.; Ploegmakers, Marleen M. J.; van Erven, Lieselot

    2012-01-01

    Current clinical guidelines for the management of radiotherapy patients having either a pacemaker or implantable cardioverter defibrillator (both CIEDs: Cardiac Implantable Electronic Devices) do not cover modern radiotherapy techniques and do not take the patient's perspective into account. Availab

  3. Worldwide experience with a totally subcutaneous implantable defibrillator

    DEFF Research Database (Denmark)

    Lambiase, Pier D; Barr, Craig; Theuns, Dominic A M J

    2014-01-01

    AIMS: The totally subcutaneous implantable-defibrillator (S-ICD) is a new alternative to the conventional transvenous ICD system to minimize intravascular lead complications. There are limited data describing the long-term performance of the S-ICD. This paper presents the first large internationa...... event rates and inappropriate shock rates comparable with those reported for conventional ICDs. Clinical trial registration URL: http://www.clinicaltrials.gov. Unique identifier NCT01085435....

  4. Cardiac sympathetic activity in chronic heart failure: cardiac (123)I-mIBG scintigraphy to improve patient selection for ICD implantation.

    Science.gov (United States)

    Verschure, D O; van Eck-Smit, B L F; Somsen, G A; Knol, R J J; Verberne, H J

    2016-12-01

    Heart failure is a life-threatening disease with a growing incidence in the Netherlands. This growing incidence is related to increased life expectancy, improvement of survival after myocardial infarction and better treatment options for heart failure. As a consequence, the costs related to heart failure care will increase. Despite huge improvements in treatment, the prognosis remains unfavourable with high one-year mortality rates. The introduction of implantable devices such as implantable cardioverter defibrillators (ICD) and cardiac resynchronisation therapy (CRT) has improved the overall survival of patients with chronic heart failure. However, after ICD implantation for primary prevention in heart failure a high percentage of patients never have appropriate ICD discharges. In addition 25-50 % of CRT patients have no therapeutic effect. Moreover, both ICDs and CRTs are associated with malfunction and complications (e. g. inappropriate shocks, infection). Last but not least is the relatively high cost of these devices. Therefore, it is essential, not only from a clinical but also from a socioeconomic point of view, to optimise the current selection criteria for ICD and CRT. This review focusses on the role of cardiac sympathetic hyperactivity in optimising ICD selection criteria. Cardiac sympathetic hyperactivity is related to fatal arrhythmias and can be non-invasively assessed with (123)I-meta-iodobenzylguanide ((123)I-mIBG) scintigraphy. We conclude that cardiac sympathetic activity assessed with (123)I-mIBG scintigraphy is a promising tool to better identify patients who will benefit from ICD implantation.

  5. [Magnets, pacemaker and defibrillator: fatal attraction?].

    Science.gov (United States)

    Bergamin, C; Graf, D

    2015-05-27

    This article aims at clarifying the effects of a clinical magnet on pacemakers and Implantable Cardioverter Defibrillators. The effects of electromagnetic interferences on such devices, including interferences linked to electrosurgery and magnetic resonance imaging are also discussed. In general, a magnet provokes a distinctive effect on a pacemaker by converting it into an asynchronous mode of pacing, and on an Implantable Cardioverter Defibrillator by suspending its own antitachyarythmia therapies without affecting the pacing. In the operating room, the magnet has to be used cautiously with precisely defined protocols which respect the type of the device used, the type of intervention planned, the presence or absence of EMI and the pacing-dependency of the patient.

  6. Defibrillation lead placement using a transthoracic transatrial approach in a case without transvenous access due to lack of the right superior vena cava.

    Science.gov (United States)

    Otsuka, Yosuke; Okamura, Hideo; Sato, Syunsuke; Nakajima, Ikutaro; Ishibashi, Kohei; Miyamoto, Kouji; Noda, Takashi; Aiba, Takeshi; Kamakura, Shiro; Kobayashi, Junjiro; Yasuda, Satoshi; Ogawa, Hisao; Kusano, Kengo

    2015-06-01

    A 65-year-old woman with a history of syncope was diagnosed with hypertrophic cardiomyopathy. She had previously undergone mastectomy of the left breast owing to breast cancer. Holter electrocardiogram (ECG) and monitor ECG revealed sick sinus syndrome (Type II) and non-sustained ventricular tachycardia. Sustained ventricular tachycardia and ventricular fibrillation were induced in an electrophysiological study. Although the patient was eligible for treatment with a dual chamber implantable cardioverter defibrillator (ICD), venography revealed lack of the right superior vena cava (R-SVC). Lead placement from the left subclavian vein would have increased the risk of lymphedema owing to the patient׳s mastectomy history. Consequently, the defibrillation lead was placed in the right ventricle by direct puncture of the right auricle through the tricuspid valve. The atrial lead was sutured to the atrial wall, and the postoperative course was unremarkable. Defibrillation lead placement using a transthoracic transatrial approach can be an alternative method in cases where a transvenous approach for lead placement is not feasible.

  7. Clinical and Serum-Based Markers Are Associated with Death within 1 year of de novo Implant in Primary Prevention ICD Recipients

    Science.gov (United States)

    Zhang, Yiyi; Guallar, Eliseo; Blasco-Colmenares, Elena; Dalal, Darshan; Butcher, Barbara; Norgard, Sanaz; Tjong, Fleur V. Y.; Eldadah, Zayd; Dickfeld, Timm; Ellenbogen, Kenneth A.; Marine, Joseph E.; Tomaselli, Gordon F.; Cheng, Alan

    2014-01-01

    Background Implantable cardioverter defibrillator (ICD) implantation is contraindicated in those with <1 year life expectancy. Objective To develop a risk prediction score for 1-year mortality in patients with primary prevention ICDs and to determine the incremental improvement in discrimination when incorporating serum-based biomarkers to traditional clinical variables. Methods We analyzed data from the PROSE-ICD study, a large prospective observational study of patients undergoing primary prevention ICD implantation who were extensively phenotyped for clinical and serum markers. We identified variables predicting 1-year mortality and synthesized them into a comprehensive risk scoring construct using backward selection. Results Among 1,189 patients deemed by their treating physicians as having reasonable 1 year life expectancy, 62 patients died within 1 year of ICD implantation. The risk score, comprised of 6 clinical factors (age ≥75 years, New York Heart Association class III/IV, atrial fibrillation, eGFR <30mL/min/1.73m2, diabetes, and use of diuretics), had good discrimination (AUC=0.77) for 1-year mortality. Addition of 3 biomarkers (TNF-αRII, pro-BNP, and cTnT) further improved model discrimination to 0.82. Patients with 0-1, 2-3, 4-6, or 7-9 risk factors had 1-year mortality rates of 0.8%, 2.7%, 16.1% and 46.2%, respectively. Conclusions Individuals with more co-morbidities and elevations of specific serum biomarkers were at increased risk for all-cause mortality despite being deemed as having reasonable 1 year life expectancy. A simple risk score comprised of readily available clinical data and serum biomarkers may better identify patients at high risk of early mortality and improve patient selection and counseling for primary prevention ICD therapy. PMID:25446153

  8. Changes in Follow-up Left Ventricular Ejection Fraction Associated with Outcomes in Primary Prevention ICD and CRT-D Recipients

    Science.gov (United States)

    Zhang, Yiyi; Guallar, Eliseo; Blasco-Colmenares, Elena; Butcher, Barbara; Norgard, Sanaz; Nauffal, Victor; Marine, Joseph E.; Eldadah, Zayd; Dickfeld, Timm; Ellenbogen, Kenneth A.; Tomaselli, Gordon F.; Cheng, Alan

    2015-01-01

    BACKGROUND Heart failure patients with primary prevention implantable cardioverter-defibrillators (ICD) may experience an improvement in left ventricular ejection fraction (LVEF) over time. However, it is unclear how LVEF improvement affects subsequent risk for mortality and sudden cardiac death (SCD). OBJECTIVES We sought to assess changes in LVEF after ICD implantation and the implication of these changes on subsequent mortality and ICD shocks. METHODS We conducted a prospective cohort study of 538 patients with repeated LVEF assessments after ICD implantation for primary prevention of SCD. The primary endpoint was appropriate ICD shock, defined as a shock for ventricular tachyarrhythmias. The secondary endpoint was all-cause mortality. RESULTS Over a mean follow-up of 4.9 years, LVEF decreased in 13.0%, improved in 40.0%, and was unchanged in 47.0% of the patients. In the multivariate Cox models comparing patients with an improved LVEF to those with an unchanged LVEF, the hazard ratios were 0.33 (95% confidence interval [CI]: 0.18 to 0.59) for mortality and 0.29 (95% CI: 0.11 to 0.78) for appropriate shock, respectively. During follow-up, 25% of patients showed an improvement in LVEF to >35% and their risk of appropriate shock decreased but was not eliminated. CONCLUSION Among primary prevention ICD patients, 40.0% had an improved LVEF during follow-up and 25% had LVEF improved to >35%. Changes in LVEF were inversely associated with all-cause mortality and appropriate shock for ventricular tachyarrhythmia. In patients whose follow-up LVEF improved to >35%, the risk of an appropriate shock remained but was markedly decreased. PMID:26227190

  9. Estudo clínico de um sistema cardioversor-desfibrilador implantável que apresenta limiares de desfibrilação baixos usando eletrodos de estrutura fractal Clinical studies of an implantable cardioversor - defibrillators system providing low defibrillation thresholds as well as high signal amplitudes due to fractal coated electrodes

    Directory of Open Access Journals (Sweden)

    Fernando A. LUCCHESE

    1999-01-01

    Full Text Available Em função do contínuo desenvolvimento tecnológico, a geração atual de cardioversores-desfibriladores implantáveis (CDI garante um alto grau de segurança e eficiência na detecção e reversão de taquiarritmias ventriculares. O presente trabalho sumariza os resultados clínicos obtidos com 1058 CDI de câmara única (Phylax 6, Phylax XM, Biotronik utilizando eletrodo único e tecnologia de carcaça ativa, SPS e Kainox RV (com uma mola intracavitária de choque, SL-ICD e Kainox SL (com duas molas intracavitárias de choque, Biotronik. Na quase totalidade dos pacientes, com exceção de 3 (> 99%, foram obtidos limiares de desfibrilação com baixa energia usando apenas um eletrodo transvenoso. Isto tem permitido substituir o teste de limiar de desfibrilação usual por um teste simples durante o implante, afim de minimizar os riscos associados com repetidas induções de fibrilação e conseqüente extensão do período de anestesia.Due to continuously improved technologies, the present generation of implantable cardioverter-defibrillators (ICD guarantees a high degree of safety and efficacy for detecting and terminating ventricular tachyarrhythmias. This paper summarizes the clinical results obtained with 1058 single-chamber ICD (Phylax 6, Phylax XM, Biotronik employing single-lead and active housing technology (SPS and Kainox RV (single coil, SL-ICD and Kainox SL (double coil, Biotronik. In all but 3 patients (> 99%, reliable low-energy defibrillation was achieved using transvenous leads only. This has led to the trend to replace DFT testing by a short function test during implantation in order to minimize the risks associated with repeated induction of fibrillation and extended anesthesia.

  10. Incidência de choques e qualidade de vida em jovens com cardioversor-desfibrilador implantável Incidence of shock and quality of life in young patients with implantable cardioverter-defibrillator

    Directory of Open Access Journals (Sweden)

    Roberto Costa

    2007-03-01

    Full Text Available OBJETIVOS: Avaliar a incidência e a causa de choques de CDI em crianças e adolescentes e sua repercussão na qualidade de vida (QV. MÉTODOS: De março/1997 a fevereiro/2006, 29 pacientes (15,7±5,4 anos foram submetidos a implante de CDI. Parada cardiorrespiratória recuperada (41,5%, taquicardia ventricular sustentada (27,6% e profilaxia primária de morte súbita cardíaca (30,9% motivaram os implantes. O número de terapias foi avaliado por entrevista e pela telemetria dos CDI. A QV foi avaliada pela aplicação do questionário SF-36 e comparada à de indivíduos saudáveis. Empregou-se o método de Kaplan-Meier para análise da sobrevida livre de choques. RESULTADOS: Após 2,6±1,8 anos de seguimento, 8 (27,6% pacientes receberam 141 choques apropriados em razão de TV polimórfica (6 ou FV (2, e 11 (37,9% sofreram 152 choques inapropriados em razão de taquiarritmias supraventriculares (8 ou oversensing (3. A expectativa de sobrevida livre de choques apropriados foi de 74,2%±9,0 após um ano, e de 66,7%±10,7 após três anos. Observou-se diminuição da QV nos aspectos físicos (61,7±28,7, na vitalidade (64,7±19,1, na saúde mental (65,9±22,7 e nos aspectos emocionais (66,7±38,5. Medo e preocupações relacionados ao CDI foram referidos por todos os pacientes. CONCLUSÃO: A despeito da grande eficácia dessa terapêutica, a incidência elevada de choques interferiu na QV e na adaptação ao dispositivo.OBJECTIVES: To analyze the incidence and causes of ICD therapies in children and young adults and verify their impact on the quality of life (QoL. METHODS: From March/1977 to February/2006, 29 patients (15.7±5.4 years old were submitted to ICD implants. Aborted cardiac arrest (41.5%, sustained ventricular tachycardia (27.6% and primary prophylaxis of sudden cardiac death (30.9% indicated device therapy. The number of therapies was evaluated by interviewing patients and by ICD diagnostic data. The SF-36 questionnaire was used to

  11. A patch in the pectoral position lowers defibrillation threshold.

    Science.gov (United States)

    Karasik, P; Solomon, A; Verdino, R; Moore, H; Rodak, D; Hannan, R; Fletcher, R

    1997-06-01

    Implantable pacemaker cardioverter defibrillators are now available with biphasic waveforms, which have been shown to markedly improve defibrillation thresholds (DFTs). However, in a number of patients the DFT remains high. Also, DFT may increase after implantation, especially if antiarrhythmic drugs are added. We report on the use of a subcutaneous patch in the pectoral position in 15 patients receiving a transvenous defibrillator as a method of easily reducing the DFT. A 660-mm2 patch electrode was placed beneath the generator in a pocket created on the pectoral fascia. The energy required for defibrillation was lowered by 56% on average, and the system impedance was lowered by a mean of 25%. This maneuver allowed all patients to undergo a successful implant with adequate safety margin.

  12. Prevention of sudden death in hypertrophic cardiomyopathy (HCM):implanted defibrillators in HCM%肥厚型心肌病猝死预防:肥厚型心肌病患者除颤器置入

    Institute of Scientific and Technical Information of China (English)

    Barry J Maron; Paolo Spirito

    2009-01-01

    Hypertrophic cardiomyopathy (HCM) is the most common cause of sudden cardiac death in young people. The implantable cardioverter-defibrillator (ICD), has recently proved to be a safe and effective therapeutic intervention in patients with HCM, both for the primary and secondary prevention of sudden death. Based on recent substantial experience, the ICD intervenes appropriately to termiante ventricular tachycardia/fibrillation (VT/VF), at a rate of 5.5%/year. ICD discharge rate is 4%/year in those patients implanted prophylactically due to one or more major risk markers, but often with considerable delays of up to 10 years before the device is required to intervene appropriately to terminate potentially letal ventricular tachyarrhythmias. Primary prevention of VT/VF occurs with similar frequency in high-risk patients having either 1,2 or ≥ 3 noninvasive risk markers, and about one-third of patients with appropriate device interventions had been implanted for only one risk factor. The ICD has proved reliable in HCM despite the extreme and complex phenotypes often present with massive degrees of left vcntricular hypertrophy, microvascular ischemia, diastolic dysfunction, or dynamic left ventricular outflow tract obstruction. Failure to convert life-threatening ventrieular tachyarrhythmias to normal rhythm is extraordinarily rare. In conclusion, in high-risk HCM patients, ICDs perform in a highly effective fashion,frequently preventing sudden death by aborting primary life-threatening ventricular tachyarrhythmias. A single marker of high risk can be sufficient evidence to justify the recommendation for a prophylactic ICD in selected patients with HCM.

  13. Polymorphisms associated with ventricular tachyarrhythmias: rationale, design, and endpoints of the 'diagnostic data influence on disease management and relation of genomics to ventricular tachyarrhythmias in implantable cardioverter/defibrillator patients (DISCOVERY)' study

    DEFF Research Database (Denmark)

    Garcia, Javier; Wieneke, Heinrich; Spencker, Sebastian;

    2010-01-01

    (SNPs) are DNA sequence variations occurring when a single nucleotide in the genome differs among members of a species. A novel concept has emerged being that these common genetic variations might modify the susceptibility of a certain population to specific diseases. Thus, genetic factors may also...... modulate the risk for arrhythmias and sudden cardiac death, and identification of common variants could help to better identify patients at risk. The DISCOVERY study is an interventional, longitudinal, prospective, multi-centre diagnostic study that will enrol 1287 patients in approximately 80 European...... centres. In the genetic part of the DISCOVERY study, candidate gene polymorphisms involved in coding of the G-protein subunits will be correlated with the occurrence of ventricular arrhythmias in patients receiving an ICD for primary prevention. Furthermore, in order to search for additional sequence...

  14. Prevención primaria y secundaria de muerte súbita en un hospital de la Seguridad Social de Costa Rica: reporte del registro de pacientes con desfibrilador automático implantable, 2007-2011 Primary and secondary prevention of sudden cardiac death in a hospital of the social security system in Costa Rica: report from the registry of patients with implantable cardioverter-defibrillators, 2007-2011

    Directory of Open Access Journals (Sweden)

    Hugo Arguedas-Jiménez

    2013-03-01

    Full Text Available Justificación y objetivo: diversos estudios han demostrado la eficacia de los desfibriladores automáticos implantables en la prevención de la muerte súbita cardiaca. La aplicación de dicha evidencia debe ser evaluada mediante registros. El objetivo de este estudio fue describir las principales características epidemiológicas y clínicas y las complicaciones de los pacientes a quienes se les implanta un desfibrilador automático implantable en un hospital de tercer nivel en Costa Rica. Métodos: estudio observacional de cohorte, retrospectivo, que incluyó la totalidad de pacientes a quienes se les implantó un desfibrilador automático implantable en el hospital “Dr. Rafael Ángel Calderón Guardia” entre 2007 y 2011. Resultados: se incluyó 23 pacientes. La edad media fue de 55 ± 18 años. La cardiopatía isquémica fue la etiología más frecuente (10 pacientes. Veinte pacientes estaban en clase funcional I o II; la fracción de eyección media fue 0,38 ± 0,17. En los 18 pacientes el desfibrilador automático se implantó por prevención secundaria. Cinco pacientes presentaron una complicación temprana, todos ellos con dispositivos bicamerales: 2 hematomas menores, una disección del seno coronario, un desplazamiento del electrodo atrial derecho y un ictus cardioembólico. Hubo un total de 101 terapias (en 8 pacientes, de las cuales 94 fueron apropiadas (en 5 pacientes y 7 inapropiadas (en 3 pacientes; dos de estos últimos habían tenido episodios previos de fibrilación atrial. Conclusión: este registro muestra que la mayoría de los implantes de desfibriladores automáticos se realizan por prevención secundaria, con una alta tasa de terapias adecuadas y una baja tasa de terapias inadecuadas y de complicaciones; además, permite evaluar las indicaciones y las complicaciones asociadas con esta terapia.Aim: Several studies have demonstrated the efficacy of implantable cardioverter-defibrillators in the prevention of sudden

  15. Towards Low Energy Atrial Defibrillation

    Directory of Open Access Journals (Sweden)

    Philip Walsh

    2015-09-01

    Full Text Available A wireless powered implantable atrial defibrillator consisting of a battery driven hand-held radio frequency (RF power transmitter (ex vivo and a passive (battery free implantable power receiver (in vivo that enables measurement of the intracardiac impedance (ICI during internal atrial defibrillation is reported. The architecture is designed to operate in two modes: Cardiac sense mode (power-up, measure the impedance of the cardiac substrate and communicate data to the ex vivo power transmitter and cardiac shock mode (delivery of a synchronised very low tilt rectilinear electrical shock waveform. An initial prototype was implemented and tested. In low-power (sense mode, >5 W was delivered across a 2.5 cm air-skin gap to facilitate measurement of the impedance of the cardiac substrate. In high-power (shock mode, >180 W (delivered as a 12 ms monophasic very-low-tilt-rectilinear (M-VLTR or as a 12 ms biphasic very-low-tilt-rectilinear (B-VLTR chronosymmetric (6ms/6ms amplitude asymmetric (negative phase at 50% magnitude shock was reliably and repeatedly delivered across the same interface; with >47% DC-to-DC (direct current to direct current power transfer efficiency at a switching frequency of 185 kHz achieved. In an initial trial of the RF architecture developed, 30 patients with AF were randomised to therapy with an RF generated M-VLTR or B-VLTR shock using a step-up voltage protocol (50–300 V. Mean energy for successful cardioversion was 8.51 J ± 3.16 J. Subsequent analysis revealed that all patients who cardioverted exhibited a significant decrease in ICI between the first and third shocks (5.00 Ω (SD(σ = 1.62 Ω, p < 0.01 while spectral analysis across frequency also revealed a significant variation in the impedance-amplitude-spectrum-area (IAMSA within the same patient group (|∆(IAMSAS1-IAMSAS3[1 Hz − 20 kHz] = 20.82 Ω-Hz (SD(σ = 10.77 Ω-Hz, p < 0.01; both trends being absent in all patients that failed to cardiovert

  16. 78 FR 43533 - Medicare and Medicaid Programs: Hospital Outpatient Prospective Payment and Ambulatory Surgical...

    Science.gov (United States)

    2013-07-19

    ..., Ninth Revision, Clinical Modification ICD Implantable cardioverter defibrillator ICU Intensive care unit...: Cardiac Rehabilitation Measure: Patient Referral From an Outpatient Setting D. Quality Measures...

  17. Registry of Malignant Arrhythmias and Sudden Cardiac Death - Influence of Diagnostics and Interventions

    Science.gov (United States)

    2016-11-30

    Ventricular Tachycardia; Ventricular Fibrillation; Sudden Cardiac Death; Coronary Angiography; Electrophysiologic Testing (EP); Catheter Ablation; Percutaneous Coronary Intervention (PCI); Internal Cardioverter Defibrillator (ICD)

  18. Sexual Health for Patients with an Implantable Cardioverter Defibrillator

    Science.gov (United States)

    ... Search Donate Circulation My alerts Sign In Join Facebook Twitter Home About this Journal Editorial Board General Statistics Circulation Doodle → Blip the Doodle Information for Advertisers Author Reprints Commercial Reprints Customer Service and Ordering ...

  19. How to Respond to an Implantable Cardioverter-Defibrillator Recall

    Science.gov (United States)

    ... Search Donate Circulation My alerts Sign In Join Facebook Twitter Home About this Journal Editorial Board General Statistics Circulation Doodle → Blip the Doodle Information for Advertisers Author Reprints Commercial Reprints Customer Service and Ordering ...

  20. Long-term efficacy of implantable cardiac resynchronization therapy plus defibrillator for primary prevention of sudden cardiac death in patients with mild heart failure: an updated meta-analysis.

    Science.gov (United States)

    Sun, Wei-Ping; Li, Chun-Lei; Guo, Jin-Cheng; Zhang, Li-Xin; Liu, Ran; Zhang, Hai-Bin; Zhang, Ling

    2016-07-01

    Previous studies of implantable cardiac resynchronization therapy plus defibrillator (CRT-D) therapy used for primary prevention of sudden cardiac death have suggested that CRT-D therapy is less effective in patients with mild heart failure and a wide QRS complex. However, the long-term benefits are variable. We performed a meta-analysis of randomized trials identified in systematic searches of MEDLINE, EMBASE, and the Cochrane Database. Three studies (3858 patients) with a mean follow-up of 66 months were included. Overall, CRT-D therapy was associated with significantly lower all-cause mortality than was implantable cardioverter defibrillator (ICD) therapy (OR, 0.78; 95 % CI, 0.63-0.96; P = 0.02; I (2) = 19 %). However, the risk of cardiac mortality was comparable between two groups (OR, 0.74; 95 % CI, 0.53-1.01; P = 0.06). CRT-D treatment was associated with a significantly lower risk of hospitalization for heart failure (OR, 0.67; 95 % CI, 0.50-0.89; P = 0.005; I (2) = 55 %). The composite outcome of all-cause mortality and hospitalization for heart failure was also markedly lower with CRT-D therapy than with ICD treatment alone (OR, 0.67; 95 % CI, 0.57-0.77; P failure events in patients with mild heart failure with a wide QRS complex. However, long-term risk of cardiac mortality was similar between two groups. More randomized studies are needed to confirm these findings, especially in patients with NYHA class I heart failure or patients without LBBB.

  1. Complications after cardiac implantable electronic device implantations

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard;

    2014-01-01

    Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient...

  2. Defibrillation in children

    Directory of Open Access Journals (Sweden)

    Haskell Sarah

    2010-01-01

    Full Text Available Defibrillation is the only effective treatment for ventricular fibrillation (VF. Optimal methods for defibrillation in children are derived and extrapolated from adult data. VF occurs as the initial rhythm in 8-20% of pediatric cardiac arrests. This has fostered a new interest in determining the optimal technique for pediatric defibrillation. This review will provide a brief background of the history of defibrillation and a review of the current literature on pediatric defibrillation. The literature search was performed through PubMed, using the MeSH headings of cardiopulmonary resuscitation, defibrillation and electric countershock. The authors′ personal bibliographic files were also searched. Only published articles were chosen. The recommended energy dose has been 2 J/kg for 30 years, but recent reports may indicate that higher dosages may be more effective and safe. In 2005, the European Resuscitation Council recommended 4 J/kg as the initial dose, without escalation for subsequent shocks. Automated external defibrillators are increasingly used for pediatric cardiac arrest, and available reports indicate high success rates. Additional research on pediatric defibrillation is critical in order to be able to provide an equivalent standard of care for children in cardiac arrest and improve outcomes.

  3. How Is Cardiomyopathy Treated?

    Science.gov (United States)

    ... contractions between the heart’s left and right ventricles. Implantable cardioverter defibrillator (ICD) . An ICD helps control life- ... assist device (LVAD) . This device helps the heart pump blood to the body. An LVAD can be ...

  4. Telomere shortening and telomerase activity in ischaemic cardiomyopathy patients

    DEFF Research Database (Denmark)

    Sawhney, V; Campbell, N G; Brouilette, S W

    2016-01-01

    BACKGROUND: Implantable cardioverter defibrillators (ICDs) reduce mortality in patients with ischaemic cardiomyopathy at high risk of ventricular arrhythmias (VA). However, the current indication for ICD prescription needs improvement. Telomere and telomerase in leucocytes have been shown to asso...

  5. Management of radiation oncology patients with a pacemaker or ICD: A new comprehensive practical guideline in The Netherlands

    Directory of Open Access Journals (Sweden)

    Hurkmans Coen W

    2012-11-01

    Full Text Available Abstract Current clinical guidelines for the management of radiotherapy patients having either a pacemaker or implantable cardioverter defibrillator (both CIEDs: Cardiac Implantable Electronic Devices do not cover modern radiotherapy techniques and do not take the patient’s perspective into account. Available data on the frequency and cause of CIED failure during radiation therapy are limited and do not converge. The Dutch Society of Radiotherapy and Oncology (NVRO initiated a multidisciplinary task group consisting of clinical physicists, cardiologists, radiation oncologists, pacemaker and ICD technologists to develop evidence based consensus guidelines for the management of CIED patients. CIED patients receiving radiotherapy should be categorised based on the chance of device failure and the clinical consequences in case of failure. Although there is no clear cut-off point nor a clear linear relationship, in general, chances of device failure increase with increasing doses. Clinical consequences of device failures like loss of pacing, carry the most risks in pacing dependent patients. Cumulative dose and pacing dependency have been combined to categorise patients into low, medium and high risk groups. Patients receiving a dose of less than 2 Gy to their CIED are categorised as low risk, unless pacing dependent since then they are medium risk. Between 2 and 10 Gy, all patients are categorised as medium risk, while above 10 Gy every patient is categorised as high risk. Measures to secure patient safety are described for each category. This guideline for the management of CIED patients receiving radiotherapy takes into account modern radiotherapy techniques, CIED technology, the patients’ perspective and the practical aspects necessary for the safe management of these patients. The guideline is implemented in The Netherlands in 2012 and is expected to find clinical acceptance outside The Netherlands as well.

  6. Position paper for management of elderly patients with pacemakers and implantable cardiac defibrillators Groupe de rythmologie et stimulation cardiaque de la Société française de cardiologie et Société française de gériatrie et gérontologie.

    Science.gov (United States)

    Fauchier, Laurent; Alonso, Christine; Anselme, Frédéric; Blangy, Hugues; Bordachar, Pierre; Boveda, Serge; Clementy, Nicolas; Defaye, Pascal; Deharo, Jean-Claude; Friocourt, Patrick; Gras, Daniel; Halimi, Franck; Klug, Didier; Mansourati, Jacques; Obadia, Benjamin; Pasquié, Jean-Luc; Pavin, Dominique; Sadoul, Nicolas; Taieb, Jérôme; Piot, Olivier; Hanon, Olivier

    2016-09-01

    Despite the increasingly high rate of implantation of pacemakers (PM) and cardioverter-defibrillators (ICD) in elderly patients, data supporting their clinical and cost-effectiveness in this age stratum are ambiguous and contradictory. We reviewed the data regarding the applicability, safety, and effectiveness of the conventional pacing, ICD and cardiac resynchronization therapy (CRT) in elderly patients. Although peri-procedural risk may be slightly higher in the elderly, the procedure of implantation of PMs and ICDs is still relatively safe in this age group. In older patients with sinus node disease, a general consensus is that dual chamber pacing, along with the programming of an algorithm to minimise ventricular pacing is preferred. In very old patients presenting with intermittent or suspected AV block, VVI pacing may be appropriate. In terms of correcting potentially life-threatening arrhythmias, the effectiveness of ICD therapy is comparable in older and younger individuals. However, the assumption of persistent ICD benefit in the elderly population is questionable, as any advantage of the device on arrhythmic death may be attenuated by a higher total non-arrhythmic mortality. While septuagenarians and octogenarians have higher annual all-cause mortality rates, ICD therapy may remain effective in selected patients at high risk of arrhythmic death and with minimum comorbidities despite advanced age. ICD implantation among the elderly, as a group, may not be cost-effective, but the procedure may reach cost-effectiveness in those expected to live >5-7 years after implantation. The elderly patients usually experience a significant functional improvement after CRT, similar to that observed in middle-aged patients. Management of CRT non responders remains globally the same, while considering a less aggressive approach in terms of re interventions (revision of LV lead placement, addition of a RV or LV lead, LV endocardial pacing configuration). Overall, age

  7. Position paper for management of elderly patients with pacemakers and implantable cardiac defibrillators: Groupe de Rythmologie et Stimulation Cardiaque de la Société Française de Cardiologie and Société Française de Gériatrie et Gérontologie.

    Science.gov (United States)

    Fauchier, Laurent; Alonso, Christine; Anselme, Frederic; Blangy, Hugues; Bordachar, Pierre; Boveda, Serge; Clementy, Nicolas; Defaye, Pascal; Deharo, Jean-Claude; Friocourt, Patrick; Gras, Daniel; Halimi, Franck; Klug, Didier; Mansourati, Jacques; Obadia, Benjamin; Pasquié, Jean-Luc; Pavin, Dominique; Sadoul, Nicolas; Taieb, Jerome; Piot, Olivier; Hanon, Olivier

    2016-10-01

    Despite the increasingly high rate of implantation of pacemakers (PMs) and implantable cardioverter defibrillators (ICDs) in elderly patients, data supporting their clinical and cost-effectiveness in this age stratum are ambiguous and contradictory. We reviewed the data regarding the applicability, safety and effectiveness of conventional pacing, ICDs and cardiac resynchronization therapy (CRT) in elderly patients. Although periprocedural risk may be slightly higher in the elderly, the implantation procedure for PMs and ICDs is still relatively safe in this age group. In older patients with sinus node disease, the general consensus is that DDD pacing with the programming of an algorithm to minimize ventricular pacing is preferred. In very old patients presenting with intermittent or suspected atrioventricular block, VVI pacing may be appropriate. In terms of correcting potentially life-threatening arrhythmias, the effectiveness of ICD therapy is similar in older and younger individuals. However, the assumption of persistent ICD benefit in the elderly population is questionable, as any advantageous effect of the device on arrhythmic death may be attenuated by higher total non-arrhythmic mortality. While septuagenarians and octogenarians have higher annual all-cause mortality rates, ICD therapy may remain effective in selected patients at high risk of arrhythmic death and with minimum comorbidities despite advanced age. ICD implantation among the elderly, as a group, may not be cost-effective, but the procedure may reach cost-effectiveness in those expected to live more than 5-7years after implantation. Elderly patients usually experience significant functional improvement after CRT, similar to that observed in middle-aged patients. Management of CRT non-responders remains globally the same, while considering a less aggressive approach in terms of reinterventions (revision of left ventricular [LV] lead placement, addition of a right ventricular or LV lead, LV

  8. DDD-ICD: discrimination of supraventricular tachyarrhythmias Discriminação de taquiarritmias supraventriculares

    Directory of Open Access Journals (Sweden)

    Amiran R. REVISHVILI

    1999-01-01

    Full Text Available Background: Dual Chamber Implantable Cardioverter Defibrillator (ICD in addition to providing hemodynamically improved bradycardia support can also reduce the incidence of inappropriate ventricular shocks owing to episodes of Supraventricular Tachycardia (SVT, with reported incidence of up to 41% of patients. An atrio-ventricular (AV discrimination algorithm is needed in dual chamber implantable cardioverter-defibrillators (ICD to avoid these inappropriate shocks. Methods: An AV discrimination algorithm, SMART DetectionTM, has been developed to differentiate between episodes of ventricular tachycardia (VT and SVT. It relies on the concept that the chamber with the higher rate is the origin of the tachycardia. The ventricular rate stability criterion is also used to detect concurrent VT during an episode of SVT. Other parameters used in the discrimination algorithm are: atrial and ventricular rhythm multiplicity, P-R regularity, sudden onset. The SMART DetectionTM algorithm has been implemented in the Biotronik Phylax® AV dual chamber ICD. The original SMART DetectionTM has been improved recently with the addition of active detection in the case of 1:1 AV conduction. Results: 10 patients were implanted with Phylax® AV's at the Bakoulev Institute. Analyses of stored dual chamber intracardiac electrogram (IEGM indicate that all episodes of VTs and Ventricular Fibrillations (VF were terminated following appropriate therapies. No episode of Atrial Flutter (Afl or Atrial Fibrillation (AF was treated even though the majority of patients have a history of SVTs. In one patient, an episode of Sinus Tachycardia (ST was inappropriately treated. Increasing the sudden onset criterion, which is used only in the case of stable 1:1 rhythms, was sufficient to prevent recurrence of inappropriate therapy. To avoid the necessity of setting the, not very reliable, sudden onset criterion an active detection procedure was developed. Isolated Premature Ventricular

  9. Ventricular Arrhythmias in Apparently Normal Hearts: Who Needs an Implantable Cardiac Defibrillator?

    Science.gov (United States)

    Tan, Alex Y; Ellenbogen, Kenneth

    2016-09-01

    Idiopathic ventricular tachycardia is often considered a benign form of ventricular arrhythmia in patients without apparent structural heart disease. However, a subset of patients may develop malignant ventricular arrhythmias and present with syncope and sudden cardiac arrest. Survivors of cardiac arrest are candidates for implantable cardiac defibrillators (ICDs). The indications for ICDs in patients with less than a full-blown cardiac arrest presentation but with electrocardiographically high-risk ectopy features remain uncertain. This article addresses some of the uncertainties and pitfalls in ICD risk stratification in this patient group and explores potential mechanisms for malignant conversion of benign premature ventricular complexes to sustained arrhythmia.

  10. Interference from a hand held radiofrequency remote control causing discharge of an implantable defibrillator.

    Science.gov (United States)

    Man, K C; Davidson, T; Langberg, J J; Morady, F; Kalbfleisch, S J

    1993-08-01

    A 46-year-old man with a history of sustained monomorphic ventricular tachycardia underwent an implantation of a third generation multiprogrammable implantable cardioverter defibrillator. One year post implant, while manipulating a remote control to a radiofrequency modulated toy car, the patient experienced a defibrillator discharge not preceded by an arrhythmia prodrome. Subsequent interrogation of the defibrillator revealed that a 34-joule shock had been delivered and had been preceded by RR intervals ranging from 141-406 msec, consistent with sensing lead noise. The remote control utilizes a 12-volt battery and has a carrier frequency of 75.95 MHz and a modulating frequency of 50 Hz. Evaluation of the remote control and defibrillator interaction revealed that the remote control was able to trigger tachyarrhythmia sensing and reproduce the clinical episode. Interference was present only when the remote control was within 8 cm of the pulse generator and at specific angles relative to the device and only when the antenna length was > 45 cm. Interference was eliminated when a ground wire was attached to the antenna and when an aluminium shield was placed between the pulse generator and the remote control. This case report suggests that patients with third generation multiprogrammable defibrillators should be cautioned against close contact with potential sources of electromagnetic interference, such as remote control units.

  11. Pacemaker, implanted cardiac defibrillator and irradiation: Management proposal in 2010 depending on the type of cardiac stimulator and prognosis and location of cancer; Pacemaker, defibrillateur et radiotherapie: propositions de conduite a tenir en 2010 en fonction du type de stimulateur cardiaque, du pronostic et du site du cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lambert, P. [Service d' anesthesie reanimation, hopital Nord, centre hospitalier universitaire de Saint-etienne, 42055 Saint-etienne cedex 2 (France); Da Costa, A. [Service de cardiologie, hopital Nord, centre hospitalier universitaire de Saint-etienne, 42055 Saint-etienne cedex 2 (France); Marcy, P.Y. [Departement de radiologie, centre Antoine-Lacassagne, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Universite Nice Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Kreps, S. [Service de radiotherapie Corad, centre regional universitaire de cancerologie Henry-S.-Kaplan, hopital Bretonneau-2, CHU de Tours, boulevard Tonnelle, 37000 Tours (France); Angellier, G.; Marcie, S.; Bondiau, P.Y. [Universite Nice Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Departement de radiotherapie oncologie, centre CyberKnife, centre Antoine-Lacassagne, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Briand-Amoros, C. [Service de radiotherapie, hopital europeen Georges-Pompidou, 20, rue Leblanc, 75015 Paris (France); Thariat, J. [Universite Nice Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Departement de radiotherapie oncologie, centre CyberKnife, centre Antoine-Lacassagne, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); IBDC CNRS UMR 6543, centre Antoine-Lacassagne, universite Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France)

    2011-06-15

    Ionizing radiation may interfere with electric components of pacemakers or implantable cardioverter defibrillators. The type, severity and extent of radiation damage to pacemakers, have previously been shown to depend on the total dose and dose rate. Over 300,000 new cancer cases are treated yearly in France, among which 60% are irradiated in the course of their disease. One among 400 of these patients has an implanted pacemaker or defibrillator. The incidence of pacemaker and implanted cardioverter defibrillator increases in an ageing population. The oncologic prognosis must be weighted against the cardiologic prognosis in a multidisciplinary and transversal setting. Innovative irradiation techniques and technological sophistications of pacemakers and implantable cardioverter-defibrillators (with the introduction of more radiosensitive complementary metal-oxide-semiconductors since 1970) have potentially changed the tolerance profiles. This review of the literature studied the geometric, dosimetric and radiobiological characteristics of the radiation beams for high energy photons, stereotactic irradiation, proton-therapy. Standardized protocols and radiotherapy optimization (particle, treatment fields, energy) are advisable in order to improve patient management during radiotherapy and prolonged monitoring is necessary following radiation therapy. The dose received at the pacemaker/heart should be calculated. The threshold for the cumulated dose to the pacemaker/implantable cardioverter-defibrillator (2 to 5 Gy depending on the brand), the necessity to remove/displace the device based on the dose-volume histogram on dosimetry, as well as the use of lead shielding and magnet are discussed. (authors)

  12. Contact dermatitis after implantable cardiac defibrillator implantation for ventricular tachycardia.

    Science.gov (United States)

    Dogan, Pinar; Inci, Sinan; Kuyumcu, Mevlut Serdar; Kus, Ozgur

    2016-02-01

    Pacemaker contact sensitivity is a rare condition. Less than 30 reports of pacemaker skin reactions have been described. We report a 57-year-old woman who underwent an implantable cardiac defibrillator (ICD) implantation for ventricular tachycardia. A skin patch test was positive on almost all components of the pacemaker system. She was treated with topical corticosteroids and skin lesions resolved within 2 weeks. Because of widespread use of various devices, we will see this more often and therefore it is important to recognize this problem and its effective management.

  13. Case report: use caution when applying magnets to pacemakers or defibrillators for surgery.

    Science.gov (United States)

    Schulman, Peter M; Rozner, Marc A

    2013-08-01

    The application of a magnet to a pacemaker (intended to cause asynchronous pacing) or implanted cardioverter defibrillator (intended to prevent shocks) during surgery without a clear understanding of actual magnet function(s) or precautions can have unexpected, untoward, or harmful consequences. In this report, we present 3 cases in which inadequate assessment of cardiac implanted electronic device (CIED) function, coupled with magnet application, contributed to or resulted in inappropriate antitachycardia pacing or shocks, CIED damage, or patient injury. Although these cases might be rare, they reinforce the need for a timely, detailed preoperative review of CIED function and programming as recommended by the American Society of Anesthesiologists and the Heart Rhythm Society.

  14. Heart failure - surgeries and devices

    Science.gov (United States)

    ... is weakened, gets too large, and does not pump blood very well, you are at high risk for abnormal heartbeats that can lead to sudden cardiac death. An implantable cardioverter-defibrillator (ICD) is a device that detects ...

  15. Commonly Asked Questions about Children and Heart Disease

    Science.gov (United States)

    ... that warrant some restrictions. Patients with pacemakers or implantable cardioverter/defibrillators (ICDs) may have restrictions not required ... right ventricle (the chamber of the heart that pumps blood to the lungs) when this chamber squeezes. ...

  16. Appendix B: Some Common Abbreviations: MedlinePlus

    Science.gov (United States)

    ... A condition in which the heart can’t pump enough blood throughout the body. CMV Cytomegalovirus A ... syndrome A problem with the large intestine ICD Implantable cardioverter defibrillator A device that monitors heart rhythm ...

  17. 78 FR 74825 - Medicare and Medicaid Programs: Hospital Outpatient Prospective Payment and Ambulatory Surgical...

    Science.gov (United States)

    2013-12-10

    ..., Clinical Modification ICD Implantable cardioverter defibrillator ICU Intensive care unit IHS Indian Health... (APC 0415) b. Direct Laryngoscopy (APC 0074) c. Pulmonary Rehabilitation Services (APC 0077) 10. Other... OP-24: Cardiac Rehabilitation Measure: Patient Referral from an Outpatient Setting D....

  18. Therapeutic options in chronic heart failure. Findings on chest X-ray; Nicht medikamentoese Therapieoptionen der chronischen Herzinsuffizienz. Befunde in der Projektionsradiografie des Thorax

    Energy Technology Data Exchange (ETDEWEB)

    Granitz, M.R.; Meissnitzer, T.; Meissnitzer, M.W.; Hergan, K.; Altenberger, J.; Granitz, C. [Uniklinikum Salzburg - Landeskrankenhaus (Austria)

    2016-05-15

    The contribution covers drugless therapeutic options for chronic heart failure: the implantable cardioverter/defibrillator (ICD), the cardiac resynchronization therapy (CRT), the interventional catheter treatment of functional mitral insufficiency, and mechanical heart supporting systems and heart transplantation.

  19. Co-constructing IT and Healthcare

    DEFF Research Database (Denmark)

    Andersen, Tariq Osman; Bansler, Jørgen P.; Bjørn, Pernille

    The CITH project (Co-constructing IT and Healthcare) is an ongoing 4-year interdisciplinary research project, which investigates while intervenes in the collaborative practices involved in disease management of chronic heart patients with an ICD (Implantable Cardioverter Defibrillator)....

  20. Questionnaire in patients and doctors with ICD indication%植入型心律转复除颤器适应证患者及主管医生的问卷调查

    Institute of Scientific and Technical Information of China (English)

    宿燕岗; 吴妍; 柏瑾; 王蔚; 葛均波

    2010-01-01

    Objective Aim to understand the extraordinary low application of implantable cardioverter defibrillator(ICD) in China. Methods patients with ICD indication,their families and the attending doctors in Zhongshan Hospital of Fudan University were investigated by questionnaire from the period of June ,2007 to Janu-ary 2008. In addition, the basic information, examination results and treatment state were collected. Results There were 122 patients enrolled in this study,including 89 patients(73.0%)with the indication of primary pre-vention for SCD,which is 2.7 times compared with the patients of the secondary prevention. Non-ischemic heart diseases are the most common underlying cause in both primary and secondary SCD prevention. 42.4% of sec-ondary prevention patients accepted ICD/CRT-D implantation,while only 2.2% of primary prevention patients re-ceived device-based therapy. Age and education has no effect on the attitude of accepting ICD treatment. In the aspect of the recognition of suffered heart diseases, sudden cardiac death (SCD)and the acceptance of ICD,patients of secondary prevention are much better than the primary prevention ones(P<0.001). When come along with mak-ing the decision of whether accepted ICD implantation, the suggestion of physicians plays the most important role. The state of illness don't need ICD treatment other than economic issue is the main reason of the patients rejecting ICD implantation. The most physicians(93.3%)never introduced ICD to their primary prevention patients due to the same reason,which is much higher(21.1%)than the secondary prevention(P<0.001). Conclusions The clinical applications of ICD are far below its indication range at present,especial in the primary prevention. The lack of un-derstanding SCD and ICD in both physician and patient is the main reason for the low implantation of ICD in China.%目的 通过对植入型心律转复除颤器(ICD)适应证患者及主管医生的问卷调查探讨国内ICD

  1. Electrostriction Effects During Defibrillation

    CERN Document Server

    Fritz, Michelle M; Roth, Bradley J

    2011-01-01

    Background-The electric field applied to the heart during defibrillation causes mechanical forces (electrostriction), and as a result the heart deforms. This paper analyses the physical origin of the deformation, and how significant it is. Methods-We represent the heart as an anisotropic cylinder. This simple geometry allows us to obtain analytical solutions for the potential, current density, charge, stress, and strain. Results-Charge induced on the heart surface in the presence of the electric field results in forces that deform the heart. In addition, the anisotropy of cardiac tissue creates a charge density throughout the tissue volume, leading to body forces. These two forces cause the tissue to deform in a complicated manner, with the anisotropy suppressing radial displacements in favor of tangential ones. Quantitatively, the deformation of the tissue is small, although it may be significant when using some imaging techniques that require the measurement of small displacements. Conclusions-The anisotrop...

  2. Specific and social phobias in ICD-11

    NARCIS (Netherlands)

    Emmelkamp, P.M.G.

    2012-01-01

    The purpose of this article is to discuss the current status of research with respect to specific phobias and social phobia as defined in the ICD-10 and DSM-IV, and to provide op- tions for their classification in the ICD-11. Both ICD-10 and DSM-IV identify three main classes of phobias: specific ph

  3. Use of Automated External Defibrillators

    Energy Technology Data Exchange (ETDEWEB)

    Gregory K Christensen

    2009-02-01

    In an effort to improve survival from cardiac arrest, the American Heart Association (AHA) has promoted the Chain of Survival concept, describing a sequence of prehospital steps that result in improved survival after sudden cardiac arrest. These interventions include immediate deployment of emergency medical services, prompt cardiopulmonary resuscitation, early defibrillation when indicated, and early initiation of advanced medical care. Early defibrillation has emerged as the most important intervention with survival decreasing by 10% with each minute of delay in defibrillation. Ventricular Fibrillation (VF) is a condition in which there is uncoordinated contraction of the heart cardiac muscle of the ventricles in the heart, making them tremble rather than contract properly. VF is a medical emergency and if the arrhythmia continues for more than a few seconds, blood circulation will cease, and death can occur in a matter of minutes. During VF, contractions of the heart are not synchronized, blood flow ceases, organs begin to fail from oxygen deprivation and within 10 minutes, death will occur. When VF occurs, the victim must be defibrillated in order to establish the heart’s normal rhythm. On average, the wait for an ambulance in populated areas of the United States is about 11 minutes. In view of these facts, the EFCOG Electrical Safety Task Group initiated this review to evaluate the potential value of deployment and use of automated external defibrillators (AEDs) for treatment of SCA victims. This evaluation indicates the long term survival benefit to victims of SCA is high if treated with CPR plus defibrillation within the first 3-5 minutes after collapse. According to the American Heart Association (AHA), survival rates as high as 74% are possible if treatment and defibrillation is performed in the first 3 minutes. In contrast survival rates are only 5% where no AED programs have been established to provide prompt CPR and defibrillation. ["CPR statistics

  4. Management of radiation therapy patients with cardiac defibrillator or pacemaker.

    Science.gov (United States)

    Salerno, Francesca; Gomellini, Sara; Caruso, Cristina; Barbara, Raffaele; Musio, Daniela; Coppi, Tamara; Cardinale, Mario; Tombolini, Vincenzo; de Paula, Ugo

    2016-06-01

    The increasing growth of population with cardiac implantable electronic devices (CIEDs) such as Pacemaker (PM) and Implantable Cardiac Defibrillators (ICD), requires particular attention in management of patients needing radiation treatment. This paper updates and summarizes some recommendations from different international guidelines. Ionizing radiation and/or electromagnetic interferences could cause device failure. Current approaches to treatment in patients who have these devices vary among radiation oncology centres. We refer to the German Society of Radiation Oncology and Cardiology guidelines (ed. 2015); to the Society of Cardiology Australia and New Zealand Statement (ed. 2015); to the guidelines in force in the Netherlands (ed. 2012) and to the Italian Association of Radiation Oncology recommendations (ed. 2013) as reported in the guidelines for the treatment of breast cancer in patients with CIED. Although there is not a clear cut-off point, risk of device failure increases with increasing doses. Cumulative dose and pacing dependency have been combined to categorize patients into low-, medium- and high-risk groups. Measures to secure patient safety are described for each category. The use of energy ≤6MV is preferable and it's strongly recommended not to exceed a total dose of 2 Gy to the PM and 1 Gy for ICD. Given the dangers of device malfunction, radiation oncology departments should adopt all the measures designed to minimize the risk to patients. For this reason, a close collaboration between cardiologist, radiotherapist and physicist is necessary.

  5. Relation of statin therapy to psychological functioning in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Theuns, Dominic A M J; Kupper, Nina;

    2013-01-01

    Statin therapy is an important secondary prevention measure in cardiovascular disease. However, the side effects associated with statin use could potentially affect patients' quality of life. Little is known about the influence of statin therapy on the well-being and health status of cardiac pati...

  6. 77 FR 20873 - Qualification of Drivers; Application for Exemptions; Implantable Cardioverter Defibrillators

    Science.gov (United States)

    2012-04-06

    ... person has no current clinical diagnosis of myocardial infarction, angina pectoris, coronary... criteria indicate that: The term ``has no current clinical diagnosis of'' (1) a current cardiovascular.... The term ``known to be accompanied by'' is designed to include a clinical diagnosis of...

  7. E-Health to Manage Distress in Patients With an Implantable Cardioverter-Defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; Denollet, Johan; Cuijpers, Pim;

    2014-01-01

    based on the problem-solving principles of cognitive behavioral therapy. RESULTS: Two hundred eighty-nine patients (85% response rate) were randomized. The prevalence of anxiety and depression ranged between 11% and 30% and 13% and 21%, respectively. No significant intervention effects were observed...

  8. Psychological vulnerability, ventricular tachyarrhythmias and mortality in implantable cardioverter defibrillator patients

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Brouwers, Corline; Versteeg, Henneke

    2012-01-01

    factors have not been considered as potential risk markers that might enhance the prediction of sudden cardiac death. This article evaluates the evidence for a link between psychological vulnerability, ventricular tachyarrhythmias and mortality and the pathways that might explain such a link. This review......, but information on the psychological profile of the patient may help to optimize the management and care of these patients in clinical practice....

  9. Long-term mortality risk in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Theuns, Dominic A M J; Pedersen, Susanne S.;

    2014-01-01

    .9)). The impact of heart rate and QRS duration on time to all-cause mortality was separately assessed with Cox proportional hazard regression analysis, adjusting for clinical factors and symptoms of depression and anxiety. RESULTS: Mean (SD) heart rate was 68.0 ± 13.3 bpm and mean QRS duration was 130.9 ± 36.9 ms....... Heart rate of ≥80 bpm was associated with increased risk of mortality (HR=1.86; 95% CI=1.15-3.00; p=.011) in unadjusted analysis. In adjusted analyses, this relationship remained significant both with depression (HR=1.86, 95% CI=1.12-3.09; p=.017) and anxiety (HR=1.82, 95% CI=1.10-3.03; p=.021...

  10. Possible Triggers and Temporal Patterns of Implantable Cardioverter Defibrillator Discharges: A Preliminary Study

    Science.gov (United States)

    1999-01-20

    there was a direct relationship between self-reported distress levels and occurrence of ectopic beats. These researchers later reported a negative...Furious (almost out of control. very angry, pounding table. slamming door) Very Angry (body tense, clenching fists or teeth ) Moderately angry (so...pounding table, slamming door) Very ADgry (body tense, clenching fists or teeth ) Moderately angry (so hassled it shows in your voice) Mlklly aDgry

  11. My Child Needs or Has an Implantable Cardioverter-Defibrillator: What Should I Do?

    Science.gov (United States)

    ... Search Donate Circulation My alerts Sign In Join Facebook Twitter Home About this Journal Editorial Board General Statistics Circulation Doodle → Blip the Doodle Information for Advertisers Author Reprints Commercial Reprints Customer Service and Ordering ...

  12. Coping with Trauma and Stressful Events As a Patient with an Implantable Cardioverter-Defibrillator

    Science.gov (United States)

    ... Search Donate Circulation My alerts Sign In Join Facebook Twitter Home About this Journal Editorial Board General Statistics Circulation Doodle → Blip the Doodle Information for Advertisers Author Reprints Commercial Reprints Customer Service and Ordering ...

  13. Automated external cardioversion defibrillation monitoring in cardiac arrest: a randomized trial

    Directory of Open Access Journals (Sweden)

    Norvel Robert

    2008-06-01

    Full Text Available Abstract Background In-hospital cardiac arrest has a poor prognosis despite active electrocardiography monitoring. The initial rhythm of approximately 25% of in-hospital cardiopulmonary resuscitation (CPR events is pulseless ventricular tachycardia/ventricular fibrillation (VT/VF. Early defibrillation is an independent predictor of survival in CPR events caused by VT/VF. The automated external cardioverter defibrillator (AECD is a device attached by pads to the chest wall that monitors, detects, and within seconds, automatically delivers electric countershock to an appropriate tachyarrhythmia. Study Objectives • To evaluate safety of AECD monitoring in hospitalized patients. • To evaluate whether AECDs provide earlier defibrillation than hospital code teams. Methods The study is a prospective trial randomizing patients admitted to the telemetry ward to standard CPR (code team or standard CPR plus AECD monitoring (PowerHeart CRM. The AECD is programmed to deliver one 150 J biphasic shock to patients in sustained VT/VF. Data is collected using the Utstein criteria for cardiac arrest. The primary endpoint is time-to-defibrillation; secondary outcomes include neurological status and survival to discharge, with 3-year follow-up. Results To date, 192 patients have been recruited in the time period between 10/10/2006 to 7/20/2007. A total of 3,655 hours of telemetry data have been analyzed in the AECD arm. The AECD has monitored ambulatory telemetry patients in sinus rhythm, sinus tachycardia, supraventricular tachycardia, atrial flutter or fibrillation, with premature ventricular complexes and non-sustained VT without delivery of inappropriate shocks. One patient experienced sustained VT during AECD monitoring, who was successfully defibrillated (17 seconds after meeting programmed criteria. There are no events to report in the control arm. The patient survived the event without neurological complications. During the same time period, mean time to

  14. The Power of Exercise-Induced T-wave Alternans to Predict Ventricular Arrhythmias in Patients with Implanted Cardiac Defibrillator

    Directory of Open Access Journals (Sweden)

    Laura Burattini

    2013-01-01

    Full Text Available The power of exercise-induced T-wave alternans (TWA to predict the occurrence of ventricular arrhythmias was evaluated in 67 patients with an implanted cardiac defibrillator (ICD. During the 4-year follow-up, electrocardiographic (ECG tracings were recorded in a bicycle ergometer test with increasing workload ranging from zero (NoWL to the patient's maximal capacity (MaxWL. After the follow-up, patients were classified as either ICD_Cases (n = 29, if developed ventricular tachycardia/fibrillation, or ICD_Controls (n = 38. TWA was quantified using our heart-rate adaptive match filter. Compared to NoWL, MaxWL was characterized by faster heart rates and higher TWA in both ICD_Cases (12-18 μ V vs. 20-39 μ V; P < 0.05 and ICD_Controls (9-15 μ V vs. 20-32 μ V; P < 0.05. Still, TWA was able to discriminate the two ICD groups during NoWL (sensitivity = 59-83%, specificity = 53-84% but not MaxWL (sensitivity = 55-69%, specificity = 39-74%. Thus, this retrospective observational case-control study suggests that TWA's predictive power for the occurrence of ventricular arrhythmias could increase at low heart rates.

  15. Conducting Retrospective Ontological Clinical Trials in ICD-9-CM in the Age of ICD-10-CM

    Science.gov (United States)

    Venepalli, Neeta K; Shergill, Ardaman; Dorestani, Parvaneh; Boyd, Andrew D

    2014-01-01

    OBJECTIVE To quantify the impact of International Classification of Disease 10th Revision Clinical Modification (ICD-10-CM) transition in cancer clinical trials by comparing coding accuracy and data discontinuity in backward ICD-10-CM to ICD-9-CM mapping via two tools, and to develop a standard ICD-9-CM and ICD-10-CM bridging methodology for retrospective analyses. BACKGROUND While the transition to ICD-10-CM has been delayed until October 2015, its impact on cancer-related studies utilizing ICD-9-CM diagnoses has been inadequately explored. MATERIALS AND METHODS Three high impact journals with broad national and international readerships were reviewed for cancer-related studies utilizing ICD-9-CM diagnoses codes in study design, methods, or results. Forward ICD-9-CM to ICD-10-CM mapping was performing using a translational methodology with the Motif web portal ICD-9-CM conversion tool. Backward mapping from ICD-10-CM to ICD-9-CM was performed using both Centers for Medicare and Medicaid Services (CMS) general equivalence mappings (GEMs) files and the Motif web portal tool. Generated ICD-9-CM codes were compared with the original ICD-9-CM codes to assess data accuracy and discontinuity. RESULTS While both methods yielded additional ICD-9-CM codes, the CMS GEMs method provided incomplete coverage with 16 of the original ICD-9-CM codes missing, whereas the Motif web portal method provided complete coverage. Of these 16 codes, 12 ICD-9-CM codes were present in 2010 Illinois Medicaid data, and accounted for 0.52% of patient encounters and 0.35% of total Medicaid reimbursements. Extraneous ICD-9-CM codes from both methods (Centers for Medicare and Medicaid Services general equivalent mapping [CMS GEMs, n = 161; Motif web portal, n = 246]) in excess of original ICD-9-CM codes accounted for 2.1% and 2.3% of total patient encounters and 3.4% and 4.1% of total Medicaid reimbursements from the 2010 Illinois Medicare database. DISCUSSION Longitudinal data analyses post-ICD-10

  16. The Effect of ICD Programming on Inappropriate and Appropriate ICD Therapies in Ischemic and Nonischemic Cardiomyopathy

    DEFF Research Database (Denmark)

    Sedláček, Kamil; Ruwald, Anne-Christine; Kutyifa, Valentina;

    2015-01-01

    INTRODUCTION: The MADIT-RIT trial demonstrated reduction of inappropriate and appropriate ICD therapies and mortality by high-rate cut-off and 60-second-delayed VT therapy ICD programming in patients with a primary prophylactic ICD indication. The aim of this analysis was to study effects of MADIT......-RIT ICD programming in patients with ischemic and nonischemic cardiomyopathy. METHODS AND RESULTS: First and total occurrences of both inappropriate and appropriate ICD therapies were analyzed by multivariate Cox models in 791 (53%) patients with ischemic and 707 (47%) patients with nonischemic......-rate cut-off (arm B) and delayed VT therapy ICD programming (arm C) compared with conventional (arm A) ICD programming were associated with a significant risk reduction of first inappropriate and appropriate ICD therapy in patients with ischemic and nonischemic cardiomyopathy (HR range 0.11-0.34, P

  17. A second defibrillator chest patch electrode will increase implantation rates for nonthoracotomy defibrillators.

    Science.gov (United States)

    Solomon, A J; Swartz, J F; Rodak, D J; Moore, H J; Hannan, R L; Tracy, C M; Fletcher, R D

    1996-09-01

    Nonthoracotomy defibrillator systems can be implanted with a lower morbidity and mortality, compared to epicardial systems. However, implantation may be unsuccessful in up to 15% of patients, using a monophasic waveform. It was the purpose of this study to prospectively examine the efficacy of a second chest patch electrode in a nonthoracotomy defibrillator system. Fourteen patients (mean age 62 +/- 11 years, ejection fraction = 0.29 +/- 0.12) with elevated defibrillation thresholds, defined as > or = 24 J, were studied. The initial lead system consisted of a right ventricular electrode (cathode), a left innominate vein, and subscapular chest patch electrode (anodes). If the initial defibrillation threshold was > or = 24 J, a second chest patch electrode was added. This was placed subcutaneously in the anterior chest (8 cases), or submuscularly in the subscapular space (6 cases). This resulted in a decrease in the system impedance at the defibrillation threshold, from 72.3 +/- 13.3 omega to 52.2 +/- 8.6 omega. Additionally, the defibrillation threshold decreased from > or = 24 J, with a single patch, to 16.6 +/- 2.8 J with two patches. These changes were associated with successful implantation of a nonthoracotomy defibrillator system in all cases. In conclusion, the addition of a second chest patch electrode (using a subscapular approach) will result in lower defibrillation thresholds in patients with high defibrillation thresholds, and will subsequently increase implantation rates for nonthoracotomy defibrillators.

  18. The use of variability of repolarization for monitoring of arrhythmic risk : "the rocking of the boat"

    NARCIS (Netherlands)

    Oosterhoff, P.

    2011-01-01

    The majority of deaths in the western world are of cardiovascular origin. Approximately 60% of these cardiovascular deaths are sudden. Implantation of an implantable cardioverter defibrillator (ICD) has been proven effective in preventing sudden cardiac death in patients at increased risk. An ICD ca

  19. Rationale and design of WEBCARE

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Spek, Viola; Theuns, Dominic A M J

    2009-01-01

    The implantable cardioverter defibrillator (ICD) is generally well accepted, but 25-33% of patients experience clinical levels of anxiety, depression, and impaired quality of life (QoL) following implantation. Few trials in ICD patients have investigated whether behavioral intervention may mitigate...

  20. Electrical Heart Defibrillation with Ion Channel Blockers

    Science.gov (United States)

    Feeney, Erin; Clark, Courtney; Puwal, Steffan

    Heart disease is the leading cause of mortality in the United States. Rotary electrical waves within heart muscle underlie electrical disorders of the heart termed fibrillation; their propagation and breakup leads to a complex distribution of electrical activation of the tissue (and of the ensuing mechanical contraction that comes from electrical activation). Successful heart defibrillation has, thus far, been limited to delivering large electrical shocks to activate the entire heart and reset its electrical activity. In theory, defibrillation of a system this nonlinear should be possible with small electrical perturbations (stimulations). A successful algorithm for such a low-energy defibrillator continues to elude researchers. We propose to examine in silica whether low-energy electrical stimulations can be combined with antiarrhythmic, ion channel-blocking drugs to achieve a higher rate of defibrillation and whether the antiarrhythmic drugs should be delivered before or after electrical stimulation has commenced. Progress toward a more successful, low-energy defibrillator will greatly minimize the adverse effects noted in defibrillation and will assist in the development of pediatric defibrillators.

  1. [The development of the ICD-11].

    Science.gov (United States)

    2011-01-01

    The ICD-10 will have been used for approximately twenty years by the time the new revision of the ICD (ICD-11) is completed, and the revision process is being implemented. Accordingly, the WHO has organized groups of experts designated to deal with issues in each field, and the International Advisory Group for the Revision of ICD-10 Mental and Behavioral Disorders has been launched for the field of psychiatry. Regarding the revision, this group is responsible for ultimate decision-making in establishing a framework for the new version. We reported processes of the ICD-11 by the above mentioned group and its coordinating groups and working groups. In addition, we reported the WHO-WPA Survey which was distributed to 500 members of the Japanese Society for Psychiatry and Neurology.

  2. Study of Cardiac Defibrillation Through Numerical Simulations

    Science.gov (United States)

    Bragard, J.; Marin, S.; Cherry, E. M.; Fenton, F. H.

    Three-dimensional numerical simulations of the defibrillation problem are presented. In particular, in this study we use the rabbit ventricular geometry as a realistic model system for evaluating the efficacy of defibrillatory shocks. Statistical data obtained from the simulations were analyzed in term of a dose-response curve. Good quantitative agreement between our numerical results and clinically relevant values is obtained. An electric field strength of about 6.6 V/cm indicates a fifty percent probability of successful defibrillation for a 12-ms monophasic shock. Our validated model will be useful for optimizing defibrillation protocols.

  3. Validation of defibrillator lead performance registry data

    DEFF Research Database (Denmark)

    Kristensen, Anders Elgaard; Larsen, Jacob Moesgaard; Nielsen, Jens Cosedis

    2017-01-01

    intervention. The validity of the less detailed overall reasons for lead interventions commonly used to report lead performance is also excellent. These findings indicate high registry data quality appropriate for scientific analysis and industry-independent post-marketing surveillance.......AIMS: The validity of registry data on defibrillator lead performance is described only sparsely, despite its clinical importance. This study investigated the validity of defibrillator lead performance registry data in a nationwide and population-based registry. METHODS AND RESULTS: We identified.......9% (95% CI: 85.2-90.2%) with a κ value of 0.82 (95% CI:0.78-0.86) representing an almost perfect match. CONCLUSION: The validity of data on defibrillator lead performance recorded in the DPIR is excellent for the specific types of lead intervention and good for the specific reasons for defibrillator lead...

  4. State of the art of ICD programming

    DEFF Research Database (Denmark)

    Mastenbroek, M H; Pedersen, Susanne S.; Versteeg, H

    2014-01-01

    , were eligible to participate. In all patients a prolonged detection of 60/80 intervals was programmed. The primary objective of the study is to investigate whether enhanced programming to further reduce ICD therapies is safe. The secondary objective is to examine the impact of enhanced programming...... of life. Hence, there has been an increasing interest in the optimisation of ICD programming to prevent inappropriate and appropriate but unnecessary device therapy. The purpose of the current report is to give an overview of research into the optimisation of ICD programming and present the design...

  5. Reliability of clinical ICD-10 schizophrenia diagnoses

    DEFF Research Database (Denmark)

    Jakobsen, Klaus D; Frederiksen, Julie N; Hansen, Thomas;

    2005-01-01

    Concern has been expressed as to the reliability of clinical ICD-10 diagnosis of schizophrenia. This study was designed to assess the diagnostic reliability of the clinical ICD-10 diagnosis of schizophrenia in a random sample of Danish in- and outpatients with a history of psychosis. A sample...... value (87%) of ICD-10 schizophrenia and an overall good agreement between clinical and OPCRIT-derived diagnoses (kappa=0.60). An even higher positive predictive value was obtained when diagnoses were amalgamated into a diagnostic entity of schizophrenia-spectrum disorders (98%). Near perfect agreement...... was seen between OPCRIT-derived ICD-10 and DSM-IV diagnoses (kappa=0.87). Thus, this study demonstrates high reliability of the clinical diagnosis of schizophrenia and even more so of the diagnosis of schizophrenia-spectrum disorder....

  6. From syncope to ICD: clinical paths of the Brugada syndrome

    Directory of Open Access Journals (Sweden)

    Ivan Comelli

    2010-09-01

    Full Text Available This review summarizes the evidences in the literature on the management of the Brugada syndrome (BS, an arrhythmogenic disease caused by genetic channelopathies, predisposing to syncope and sudden cardiac death in young, apparently healthy, typically male subjects, in the third and fourth decade of their life. Sudden cardiac death (SCD is defined as natural death from cardiac causes, heralded by abrupt loss of consciousness within one hour of the onset of symptoms. It ranks among the main causes of death in the western world, with an incidence ranging from 0.36 and 1.28‰ inhabitants per year, equal to 300,000 cases a year in the USA. In the majority of the cases it is due to the onset of arrhythmia in subjects with structural cardiac diseases, especially ischemic heart disease. However, in a non-negligible percentage of the cases, about 5-10%, the SCD arises in relatively young individuals in whom cardiac anomalies cannot be detected using traditional diagnostic techniques. About 20% of these cases can be attributed to SB. In spite of the many efforts produced to identify an effective pharmacological treatment, to date the only aid to reduce the mortality rate in subjects with SB is an implantable cardio-defibrillator (ICD. Since this approach often entails complications, the efforts of the scientific community is now focused on the assessment of the arrhythmic risk. The identification of high-risk subjects is one of the chief objectives in the therapeutic decision-making process. ABSTRACT clinica e terapia emergency

  7. 鱼油对心脏复律除颤器植入患者室性快速性心律失常及死亡的影响ω-3脂肪酸与室性心律失常随机试验研究(SOFA)%Effect of Fish Oil on Ventricular Tachyarrhythmia and Death in Patients With Implantable Cardioverter Defibrillators The Study on Omega-3 Fatty Acids and Ventricular Arrhythmia (SOFA) Randomized Trial

    Institute of Scientific and Technical Information of China (English)

    Ingeborg A. Brouwer; Peter L. Zock; A. John Camm; 顾佳

    2007-01-01

    背景:人们认为,鱼体内的长链多元不饱和脂肪酸(ω-3PUFAs)可减少心律失常的发生,从而降低猝死的风险.目的:比较鱼油保健品及安慰剂对室性快速性心律失常及死亡的影响.设计、地点及患者:"ω-3脂肪酸与室性心律失常关系研究"(Study on Omega-3 Fatty acids and ventricular Arrhythmia,SOFA)是在欧洲26家心脏诊所中开展的一项随机、平行、安慰剂对照、双盲试验.自2001年10月起至2004年8月止,共有546名携有植入式心脏复律除颤器(implantable cardioverterdefibrillators,ICDs)的恶性室性心动过速(ventricular tachycardia,VT)患者和心室纤颤(ventricular fibrillation,VF)患者纳入研究.这些患者随机服用鱼油(2 g/d,n=273)或安慰剂(n=273),平均356天(范围为14~379天).主要观测指标:VT或VF患者接受ICD干预的情况以及全因死亡率.结果:主要研究终点见于81例(30%)服用鱼油的患者和90例(33%)服用安慰剂的患者(风险比[hazard ratio,HR],0.86;95%可信区间[confidence interval,CI],0.64~1.16;P=0.33).特定的亚组分析显示,有411例患者在纳入研究前一年内出现了VT,有332例患者既往曾患有心肌梗死,其中服用鱼油者与服用安慰剂者相比HR分别为0.91(95%CI,0.66~1.26)和0.76(95%CI,0.52~1.11).结论:我们的结果显示,摄入鱼油中的ω-3 PUFAs并不能对携有ICDs的室性心律失常患者产生强有力的保护作用.

  8. [Research on automatic external defibrillator based on DSP].

    Science.gov (United States)

    Jing, Jun; Ding, Jingyan; Zhang, Wei; Hong, Wenxue

    2012-10-01

    Electrical defibrillation is the most effective way to treat the ventricular tachycardia (VT) and ventricular fibrillation (VF). An automatic external defibrillator based on DSP is introduced in this paper. The whole design consists of the signal collection module, the microprocessor controlingl module, the display module, the defibrillation module and the automatic recognition algorithm for VF and non VF, etc. This automatic external defibrillator has achieved goals such as ECG signal real-time acquisition, ECG wave synchronous display, data delivering to U disk and automatic defibrillate when shockable rhythm appears, etc.

  9. Imaging of Ventricular Fibrillation and Defibrillation: The Virtual Electrode Hypothesis.

    Science.gov (United States)

    Boukens, Bastiaan J; Gutbrod, Sarah R; Efimov, Igor R

    2015-01-01

    Ventricular fibrillation is the major underlying cause of sudden cardiac death. Understanding the complex activation patterns that give rise to ventricular fibrillation requires high resolution mapping of localized activation. The use of multi-electrode mapping unraveled re-entrant activation patterns that underlie ventricular fibrillation. However, optical mapping contributed critically to understanding the mechanism of defibrillation, where multi-electrode recordings could not measure activation patterns during and immediately after a shock. In addition, optical mapping visualizes the virtual electrodes that are generated during stimulation and defibrillation pulses, which contributed to the formulation of the virtual electrode hypothesis. The generation of virtual electrode induced phase singularities during defibrillation is arrhythmogenic and may lead to the induction of fibrillation subsequent to defibrillation. Defibrillating with low energy may circumvent this problem. Therefore, the current challenge is to use the knowledge provided by optical mapping to develop a low energy approach of defibrillation, which may lead to more successful defibrillation.

  10. Technologic advances and program initiatives in public access defibrillation using automated external defibrillators.

    Science.gov (United States)

    White, R D

    2001-06-01

    Widespread provision of early defibrillation following cardiac arrest holds major promise for improved survival from ventricular fibrillation. The critical element in predicting a successful outcome is the rapidity with which defibrillation is achieved. A worldwide awareness of this potential and its advocacy by such organizations as the American Heart Association have been pivotal in the evolution of initiatives to make defibrillation more widely and more rapidly available. The feasibility of this initiative, known as public access defibrillation, is in large measure a direct consequence of major technologic advances in automated external defibrillators (AEDs). New low-energy waveforms with biphasic morphology have been shown to be more effective in terminating ventricular fibrillation and may do so with less myocardial injury. Placement of AEDs in a variety of nontraditional settings such as police cars, aircraft and airport terminals, and gambling casinos has been shown to yield an impressive number of survivors of cardiac arrest in ventricular fibrillation. Questions yet to be answered center on the appropriate disposition of AEDs in public access defibrillation settings, training and retraining issues, device maintenance, and collection of accurate data to document benefit and to identify areas of needed improvement or expansion of AED availability.

  11. [Cardiac Pacemakers, implantable defibrillators and IRM].

    Science.gov (United States)

    Frank, R; Hidden-Lucet, F; Himbert, C; Petitot, J C; Fontaine, G

    2003-04-01

    The IRM is formally contraindicated to the pacemaker and cardiac defibrillator wearers because of the risk of inhibition or inappropriate stimulations during the examination. However if the examination is essential, suitable programming of the apparatus and a constant monitoring of the heartbeat rate by a qualified doctor in cardiac stimulation must make it possible to avoid any accident.

  12. 75 FR 70015 - External Defibrillators; Public Workshop

    Science.gov (United States)

    2010-11-16

    ... of innovative AED features such as automated integration into local 9-1-1 systems. FDA will work with... consumers, to share perspectives. II. Topics for Discussion at the Public Workshop The public workshop will... signals, or enhance the use of external defibrillators? III. Transcripts Please be advised that as soon...

  13. Reliability of clinical ICD-10 schizophrenia diagnoses

    DEFF Research Database (Denmark)

    Jakobsen, Klaus D; Frederiksen, Julie N; Hansen, Thomas;

    2005-01-01

    value (87%) of ICD-10 schizophrenia and an overall good agreement between clinical and OPCRIT-derived diagnoses (kappa=0.60). An even higher positive predictive value was obtained when diagnoses were amalgamated into a diagnostic entity of schizophrenia-spectrum disorders (98%). Near perfect agreement...

  14. COPE-ICD: Patient experience of participation in an ICD specific rehabilitation programme

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Pedersen, Birthe Dagmar; Svendsen, Jesper Hastrup

    2012-01-01

    PURPOSE: Evaluating rehabilitation programmes from the patient's perspective is much needed, as the patients are the most important stakeholders in the health care system. A comprehensive rehabilitation programme, COPE-ICD programme, consists of exercise training and nursing consultations during...... a one year period post ICD implantation. The purpose of this paper is to describe the experience and meaning of participating in a comprehensive ICD-specific rehabilitation programme. METHODS: Qualitative interviews were conducted with 10 patients representing the participating population, and later...... transcribed. The analysis was inspired by Ricoeur's theory of interpretation, which consists of three levels: naive reading, structured analysis and critical interpretation and discussion. RESULTS: The overall concept was that participating in the COPE-ICD programme meant feeling inspired and secure through...

  15. Comparison of ICD-10 and Gillberg's Criteria for Asperger Syndrome.

    Science.gov (United States)

    Leekam, Susan; Libby, Sarah; Wing, Lorna; Gould, Judith; Gillberg, Christopher

    2000-01-01

    This study compared the ICD-10 criteria for Asperger syndrome with those suggested by Gillberg with 200 children and adults who met ICD-10 criteria for autism. Comparison indicated only three subjects met ICD-10 criteria for Asperger syndrome whereas 91 met Gillberg's criteria. The discrepancy appeared due to the specific "normal development"…

  16. A shocking past: a walk through generations of defibrillation development.

    Science.gov (United States)

    Gutbrod, Sarah R; Efimov, Igor R

    2014-05-01

    Defibrillation is one of the most successful and widely recognized applications of electrotherapy. Yet the historical road to its first successful application in a patient and the innovative adaptation to an implantable device is marred with unexpected turns, political and personal setbacks, and public and scientific condemnation at each new idea. Driven by dedicated scientists and ever-advancing creative applications of new technologies, from electrocardiography to high density mapping and computational simulations, the field of defibrillation persevered and continued to evolve to the life-saving tool it is today. In addition to critical technological advances, the history of defibrillation is also marked by the plasticity of the theory of defibrillation. The advancing theories of success have propelled the campaign for reducing the defibrillation energy requirement, instilling hope in the development of a painless and harmless electrical defibrillation strategy.

  17. PTSD in ICD-10 and proposed ICD-11 in elderly with childhood trauma: prevalence, factor structure, and symptom profiles

    OpenAIRE

    Glück, Tobias M.; Knefel, Matthias; Tran, Ulrich S.; Lueger-Schuster, Brigitte

    2016-01-01

    Background: The proposal for ICD-11 postulates major changes for posttraumatic stress disorder (PTSD) diagnosis, which needs investigation in different samples.Aims: To investigate differences of PTSD prevalence and diagnostic agreement between ICD-10 and ICD-11, factor structure of proposed ICD-11 PTSD, and diagnostic value of PTSD symptom severity classes.Method: Confirmatory factor analysis and latent profile analysis were used on data of elderly survivors of childhood trauma (>60 years...

  18. Stereotyped movement disorder in ICD-11.

    Science.gov (United States)

    Stein, Dan J; Woods, Douglas W

    2014-01-01

    According to current proposals for ICD-11, stereotyped movement disorder will be classified in the grouping of neurodevelopmental disorders, with a qualifier to indicate whether self-injury is present, similar to the classification of stereotypic movement disorder in DSM-5. At the same time, the WHO ICD-11 Working Group on the Classification of Obsessive-Compulsive and Related Disorders has proposed a grouping of body-focused repetitive behavior disorders within the obsessive-compulsive and related disorders (OCRD) cluster to include trichotillomania and skin-picking disorder. DSM-5 has taken a slightly different approach: trichotillomania and excoriation (skin picking) disorder are included in the OCRD grouping, while body-focused repetitive behavior disorder is listed under other specified forms of OCRD. DSM-5 also includes a separate category of nonsuicidal self-injury in the section on "conditions for further study." There are a number of unresolved nosological questions regarding the relationships among stereotyped movement disorder, body-focused repetitive behavior disorders, and nonsuicidal self-injury. In this article, we attempt to provide preliminary answers to some of these questions as they relate to the ICD-11 classification of mental and behavioral disorders.

  19. Legal aspects in implantable defibrillator extraction.

    Science.gov (United States)

    D'Ovidio, C; Costantini, S; Vellante, P; Carnevale, A

    2013-10-01

    At the Institute of Legal Medicine in Chieti, a case of iatrogenic superior vena cava perforation was observed during laser extraction of an infected biventricular implantable cardiac defibrillator. The presentation of this particular case represented a starting point for studying the occurrence of similar complications in literature, since their knowledge and understanding should induce resolution of any organisation problems, aid in increasing physicians' training and impose the availability of cardiac surgeons during such operations.

  20. Fast Electrocardiogram Amplifier Recovery after Defibrillation Shock

    Directory of Open Access Journals (Sweden)

    Ivan Dotsinsky

    2005-04-01

    Full Text Available A procedure for fast ECG amplifier recovery after defibrillation shocks was developed and simulated in the MATLAB environment. Exponentially decaying post-shock voltages have been recorded. Signals from the AHA database are taken and mixed with the recorded exponential disturbances. The algorithm applies moving averaging (comb filter on the compound input signal, thereby obtaining the samples of the disturbance. They are currently subtracted from the input signal. The results obtained show that its recovery is practically instantaneous.

  1. Poor health status and distress in cardiac patients

    DEFF Research Database (Denmark)

    Habibović, Mirela; Versteeg, Henneke; Pelle, Aline J M;

    2013-01-01

    Implantable cardioverter defibrillator (ICD) therapy, which includes the risk of shocks, is considered the primary culprit of reductions in patient reported outcomes (PROs; e.g. health status and distress), thereby negating the role of underlying disease severity. We examined the relative influence...

  2. 77 FR 68209 - Medicare and Medicaid Programs: Hospital Outpatient Prospective Payment and Ambulatory Surgical...

    Science.gov (United States)

    2012-11-15

    ... Agent (APC 0207) d. Programmable Implantable Pump (APC 0691) e. Revision/Removal of Neurostimulator..., Ninth Revision, Clinical Modification ICD Implantable cardioverter defibrillator ICU Intensive care unit... Implantable Biologicals (``Policy-Packaged'' Drugs and Devices) h. Summary of Proposals 4. Calculation of...

  3. 77 FR 16038 - Circulatory System Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2012-03-19

    ... by HeartWare, Inc. The HVAS is an implantable electrically powered centrifugal-flow rotary blood pump... require the creation of an abdominal pump pocket. The HVAS is indicated for use as a bridge to cardiac... Subcutaneous Implantable Cardioverter Defibrillator (S-ICD) System sponsored by Cameron Health, Inc. The...

  4. Does electrophysiological testing have any role in risk stratification for sudden cardiac death?

    Institute of Scientific and Technical Information of China (English)

    Fei Lü; Wei Hua

    2010-01-01

    @@ Introduction Implantation of implantable cardioverter defibrillators (ICD) has widely been accepted for secondary prevention of sudden cardiac death (SCD) in cardiac arrest survivors.1 Currently there are increasing interests in primary prevention of SCD in selected high risk patients who have not experienced cardiac arrest.1

  5. 78 FR 58328 - Change-1 to Navigation and Inspection Circular 04-08

    Science.gov (United States)

    2013-09-23

    ... have had either anti- tachycardia devices or implantable cardioverter defibrillators implanted, and to... tachycardia within the last three years; (3) The ICD or anti-tachycardia device was implanted more than three...) Lidocaine-induced seizure during a dental appointment; (b) Concussive seizure, loss of consciousness...

  6. Genoplivning med automatisk ekstern defibrillator på hospital

    DEFF Research Database (Denmark)

    Løfgren, Bo; Wahlgreen, Claus; Hoffmann, Anne Mette;

    2009-01-01

    Early defibrillation is a determinant of survival in cardiac arrest. We report a Danish case of successful in-hospital resuscitation using an automated external defibrillator (AED). This case illustrates important aspects of implementation of in-hospital use of an AED, i.e. location of the AED, e...

  7. PTSD in ICD-10 and proposed ICD-11 in elderly with childhood trauma: prevalence, factor structure, and symptom profiles

    Directory of Open Access Journals (Sweden)

    Tobias M. Glück

    2016-01-01

    Full Text Available Background: The proposal for ICD-11 postulates major changes for posttraumatic stress disorder (PTSD diagnosis, which needs investigation in different samples. Aims: To investigate differences of PTSD prevalence and diagnostic agreement between ICD-10 and ICD-11, factor structure of proposed ICD-11 PTSD, and diagnostic value of PTSD symptom severity classes. Method: Confirmatory factor analysis and latent profile analysis were used on data of elderly survivors of childhood trauma (>60 years, N=399. Results: PTSD rates differed significantly between ICD-10 (15.0% and ICD-11 (10.3%, z=2.02, p=0.04. Unlike previous research, a one-factor solution of ICD-11 PTSD had the best fit in this sample. High symptom profiles were associated with PTSD in ICD-11. Conclusions: ICD-11 concentrates on PTSD's core symptoms and furthers clinical utility. Questions remain regarding the tendency of ICD-11 to diagnose mainly cases with severe symptoms and the influence of trauma type and participant age on the factor structure.

  8. [Treatment manual for psychotherapy of acute and posttraumatic stress disorders after multiple ICD shocks].

    Science.gov (United States)

    Jordan, J; Titscher, G; Kirsch, H

    2011-09-01

    In view of the inceasing number of implanted defibrillators in all industrial nations, the number of people who have suffered so-called multiple shocks (electrical storm, ES) also increases. Common complaints are severe and continuously recurrent massive anxiety, panic attacks, fear of death, helplessness and hopelessness, depression, nervosity and irritability as well as reclusive and uncontrollable avoidance behaviour, intrusions, nightmares, flashbacks, sleeplessness and the inability to show feelings and limitation of future perspectives. Because people with an ICD are often physically (very) ill and after multiple ICD shocks are additionally very insecure, it would seem logical if the inpatient treatment would be carried out in an institution which has close connections and is also spatially close to a cardiology department. The basis of the diagnostics is the clinical anamnesis and a systematic exploration of the trauma situation and the resulting complaints. As an additional diagnostic element psychological test procedures should be implemented to determine the core symptomatic (anxiety, depression, trauma symptoms). Psychological test procedures should be included in the diagnostics so that at the end of treatment it is obvious even to the patient which alterations have occurred. The core element of inpatient treatment is daily intensive psychotherapy and includes deep psychologically well-founded psychotherapy and behavioral therapeutic-oriented anxiety therapy as well as cognitive restructuring and elements of eye movement desensitization and reprocessing (EMDR). A follow-up examination within 4 months of the multiple shocks episode is recommended because symptoms of posttraumatic stress disorder often occur after a long latent time period.

  9. Preparing for ICD-10 and conforming your documentation.

    Science.gov (United States)

    Buckholtz, Rhonda

    2013-01-01

    There are many unknowns right now with the implementation of ICD-10-CM. However, tackling a few obstacles early on along with a keen sense of ICD-10 awareness will put you ahead of the game and able to continue on after October 1, 2014. Waiting until the last minute in hopes of delays will surely hinder the financial stability of your practice. This article will take you through what is needed for ICD-10 implementation and help you jumpstart your efforts.

  10. ICDS database: interrupted CoDing sequences in prokaryotic genomes.

    Science.gov (United States)

    Perrodou, Emmanuel; Deshayes, Caroline; Muller, Jean; Schaeffer, Christine; Van Dorsselaer, Alain; Ripp, Raymond; Poch, Olivier; Reyrat, Jean-Marc; Lecompte, Odile

    2006-01-01

    Unrecognized frameshifts, in-frame stop codons and sequencing errors lead to Interrupted CoDing Sequence (ICDS) that can seriously affect all subsequent steps of functional characterization, from in silico analysis to high-throughput proteomic projects. Here, we describe the Interrupted CoDing Sequence database containing ICDS detected by a similarity-based approach in 80 complete prokaryotic genomes. ICDS can be retrieved by species browsing or similarity searches via a web interface (http://www-bio3d-igbmc.u-strasbg.fr/ICDS/). The definition of each interrupted gene is provided as well as the ICDS genomic localization with the surrounding sequence. Furthermore, to facilitate the experimental characterization of ICDS, we propose optimized primers for re-sequencing purposes. The database will be regularly updated with additional data from ongoing sequenced genomes. Our strategy has been validated by three independent tests: (i) ICDS prediction on a benchmark of artificially created frameshifts, (ii) comparison of predicted ICDS and results obtained from the comparison of the two genomic sequences of Bacillus licheniformis strain ATCC 14580 and (iii) re-sequencing of 25 predicted ICDS of the recently sequenced genome of Mycobacterium smegmatis. This allows us to estimate the specificity and sensitivity (95 and 82%, respectively) of our program and the efficiency of primer determination.

  11. Dollars and sense: Mitigating budget risk for ICD-10.

    Science.gov (United States)

    Newell, Lucy Mancini; DeSilva, Joseph J

    2013-02-01

    The extended deadline for ICD-10 implementation is time that should not be wasted. Healthcare leaders should keep three things in mind: CFOs should approach the effort knowing the costs of ICD-10 implementation will be high and spread over multiple budget years. Training, productivity, and contractual issues are among key areas that will be challenged by ICD-10 implementation. Healthcare finance leaders should work to improve cash-on-hand and cash reserves prior to the ICD-10 deadline to ensure liquidity post-compliance.

  12. Neurodevelopmental Disorders (ASD and ADHD): DSM-5, ICD-10, and ICD-11.

    Science.gov (United States)

    Doernberg, Ellen; Hollander, Eric

    2016-08-01

    Neurodevelopmental disorders, specifically autism spectrum disorder (ASD) and attention-deficit/hyperactivity disorder (ADHD) have undergone considerable diagnostic evolution in the past decade. In the United States, the current system in place is the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5), whereas worldwide, the International Statistical Classification of Diseases and Related Health Problems, Tenth Revision (ICD-10) serves as a general medical system. This review will examine the differences in neurodevelopmental disorders between these two systems. First, we will review the important revisions made from the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision (DSM-IV-TR) to the DSM-5, with respect to ASD and ADHD. Next, we will cover the similarities and differences between ASD and ADHD classification in the DSM-5 and the ICD-10, and how these differences may have an effect on neurodevelopmental disorder diagnostics and classification. By examining the changes made for the DSM-5 in 2013, and critiquing the current ICD-10 system, we can help to anticipate and advise on the upcoming ICD-11, due to come online in 2017. Overall, this review serves to highlight the importance of progress towards complementary diagnostic classification systems, keeping in mind the difference in tradition and purpose of the DSM and the ICD, and that these systems are dynamic and changing as more is learned about neurodevelopmental disorders and their underlying etiology. Finally this review will discuss alternative diagnostic approaches, such as the Research Domain Criteria (RDoC) initiative, which links symptom domains to underlying biological and neurological mechanisms. The incorporation of new diagnostic directions could have a great effect on treatment development and insurance coverage for neurodevelopmental disorders worldwide.

  13. Sex-Based Differences in Cardiac Arrhythmias, ICD Utilisation and Cardiac Resynchronisation Therapy.

    Science.gov (United States)

    Ghani, A; Maas, A H E M; Delnoy, P P H M; Ramdat Misier, A R; Ottervanger, J P; Elvan, A

    2011-01-01

    Many important differences in the presentation and clinical course of cardiac arrhythmias are present between men and women that should be accounted for in clinical practice. In this paper, we review published data on gender differences in cardiac excitable properties, supraventricular tachycardias, ventricular tachycardias, sudden cardiac death, and the utilisation of implantable defibrillators and cardiac resynchronisation therapy. Women have a higher heart rate at rest, and a longer QT interval than men. They further have a narrower QRS complex and lower QRS voltages on the 12-lead ECG with more often non-specific repolarisation abnormalities at rest. Supraventricular tachycardias, such as AV nodal reentrant tachycardia, are twice as frequent in women compared with men. Atrial fibrillation, however, has a 1.5-fold higher prevalence in men. The triggers for idiopathic right ventricular outflow tract tachycardia (VT) initiation are gender specific, i.e. hormonal changes play an important role in the occurrence of these VTs in women. There are clear-cut gender differences in acquired and congenital LQTS. Brugada syndrome affects men more commonly and severely than women. Sudden cardiac death is less prevalent in women at all ages and occurs 10 years later in women than in men. This may be related to the later onset of clinically manifest coronary heart disease in women. Among patients who receive ICDs and CRT devices, women appear to be under-represented, while they may benefit even more from these novel therapies.

  14. The use of automated external defibrillators and public access defibrillators in the mountains: official guidelines of the international commission for mountain emergency medicine ICAR-MEDCOM.

    Science.gov (United States)

    Elsensohn, Fidel; Agazzi, Giancelso; Syme, David; Swangard, Michael; Facchetti, Gianluca; Brugger, Hermann

    2006-01-01

    In this article we propose guidelines for rational use of automated external defibrillators and public access defibrillators in the mountains. In cases of ventricular fibrillation and pulseless ventricular tachycardia, early defibrillation is the most effective therapy. Easy access to mountainous areas permits visitation by persons with high risks for sudden cardiac death, and medical trials show the benefit of exercising in moderate altitude. The introduction of public access defibrillators in popular areas in the mountains may lead to a reduction of fatal outcome of cardiac arrest. Public access defibrillators should be placed with priority in popular ski areas, in busy mountain huts and restaurants, at mass-participation events, and in remote but often-visited locations that do not have medical coverage. Automated external defibrillators should be available to first-responder groups and mountain-rescue teams. It is important that people know how to perform cardiopulmonary resuscitation and how to use public access defibrillators and automated external defibrillators.

  15. [ILCOR recommendation on signage of automated external defibrillators (AEDs)].

    Science.gov (United States)

    Truhlár, A

    2010-05-01

    Early defibrillation is a determinant of survival in both out-of-hospital and in-hospital cardiac arrests from ventricular fibrillation and pulseless ventricular tachycardia. The review summarizes importance of early defibrillation with automated external defibrillators (AED) and presents the International Liaison Committee on Resuscitation (ILCOR) recommendation for universal AED sign. The aim of the recommendation is to unify the AED signs worldwide and to spread the knowledge of this. The public in general, but healthcare professionals particularly, should be able to recognize AED location and use the device immediately in case of cardiac arrest.

  16. Impact of the Transition to ICD-10 on Medicare Payment

    Data.gov (United States)

    U.S. Department of Health & Human Services — Although the transition from the ICD-9-CM to the ICD-10 version of MS-DRGs resulted in 1.68 percent of the patients being assigned to a different MS-DRG, payment...

  17. Patient satisfaction and suggestions for improvement of remote ICD monitoring

    DEFF Research Database (Denmark)

    Petersen, Helen Høgh; Larsen, Mie Christa Jensen; Nielsen, Olav Wendelboe;

    2012-01-01

    with a letter. Eighty-four percent preferred more detailed information concerning ICD leads, battery status, and ICD therapies. A total of 96 patients (25%) had performed extra unscheduled remote transmissions: 20 due to shock, 20 due to alarm, 35 due to palpitations, and 18 for other or combined reasons...

  18. Identification of ICD Codes Suggestive of Child Maltreatment

    Science.gov (United States)

    Schnitzer, Patricia G.; Slusher, Paula L.; Kruse, Robin L.; Tarleton, Molly M.

    2011-01-01

    Objective: In order to be reimbursed for the care they provide, hospitals in the United States are required to use a standard system to code all discharge diagnoses: the International Classification of Disease, 9th Revision, Clinical Modification (ICD-9). Although ICD-9 codes specific for child maltreatment exist, they do not identify all…

  19. [ICD diagnoses in university polyclinic naturopathy consultation].

    Science.gov (United States)

    Hentschel, C; Lindner, M; Brinkhaus, B; Nagel, M R; Hahn, E G; Kohnen, R

    1996-08-01

    In a special consulting office for complementary medicine, ambulatory patients interested in receiving adjuvant treatment with complementary medicine can obtain a relevant advice and critical information regarding non-evaluated therapies. Within the framework of a retrospective statistical analysis, the diagnosis documented over a period of 24 months in accordance with the 4-digit ICD code were evaluated. In particular patients with chronic and/or functional illnesses had additional treatment needs. The exponential growth in the numbers of patients during the course of the observation period illustrates the increasing importance of complementary medical measures. However, in view of the considerable political significance of the cost factor and the possible risks of the treatment, only properly evaluated complementary medical therapies should be employed.

  20. Primärprävention des plötzlichen Herztodes mit implantierbaren Cardioverter-Defibrillatoren - Vernünftig oder MADIT?

    Directory of Open Access Journals (Sweden)

    Steinwender C

    2004-01-01

    Full Text Available Mehrere in jüngerer Zeit publizierte Studien belegen die Überlegenheit des implantierbaren Cardioverter-Defibrillators gegenüber einer medikamentösen Therapie in der Primärprävention des plötzlichen Herztodes. Die Kollektive dieser Untersuchungen bestanden aus den bekannten Hochrisikopatienten im Postinfarktstadium mit höher- bis höchstgradig eingeschränkter Linksventrikelfunktion. MADIT II war die erste Studie, die auf eine aufwendige rhythmologische Risikostratifizierung verzichtete und dennoch in sämtlichen Subgruppen einen therapeutischen Benefit durch die Defibrillatortherapie nachwies. Die sich hierdurch ergebende Evidenz fand rasch Eingang in die Richtlinien der großen kardiologischen Gesellschaften. Ungelöst bleiben vorerst zwei große Probleme: 1. die Frage der Finanzierung einer Umsetzung dieser Richtlinien; 2. die weitere Strategie zur effektiven Primärprävention des plötzlichen Herztodes, da durch oben genannte Studien nur ein kleiner Prozentsatz der möglichen künftigen Opfer abgedeckt wird. Als Lösungsansatz bietet sich eine kostengünstige, auf die Erfordernisse der Primärprävention abgestimmte Defibrillator-Technologie an, die gemeinsam mit einer Vereinfachung der Implantationsprozedur die Kosteneffektivität zugunsten der Prophylaxe beeinflussen kann. Weiters müssen zusätzlich große Anstrengungen zur Identifizierung von zukünftigen Opfern des plötzlichen Herztodes vor ihrer ersten Arrhythmie-Episode unternommen werden.

  1. Development of a current-controlled defibrillator for clinical tests.

    Science.gov (United States)

    Fischer, M; Schönegg, M; Schöchlin, J; Bolz, A

    2002-01-01

    The work presented here is only a part of the development for a new current-controlled defibrillator. In the diploma thesis "Development and construction of a current-controlled defibrillator for clinical tests" the most important part was the control and safety of the defibrillator. To ensure a safe circuit design, a risk-analysis and a Failure Mode and Effects Analysis (FMEA) were necessary. Another major part was the programming of a microcontroller in embedded C and a programmable logic device in Very High Speed Integrated Circuit Description Language (VHDL). The circuit had to be constructed, and the defibrillator was optically decoupled from the laptop for safety reasons. The waveform-data can be transmitted to the microcontroller from the laptop, and the logged data is then transmitted back.

  2. Single lead catheter of implantable cardioverterdefibrillator with floating atrial sensing dipole implanted via persistent left superior vena cava

    Institute of Scientific and Technical Information of China (English)

    Michele Malagù; Tiziano Toselli; Matteo Bertini

    2016-01-01

    Persistent left superior vena cava(LSVC) is a congenital anomaly with 0.3%-1% prevalence in the general population. It is usually asymptomatic but in case of transvenous lead positioning, i.e., for pacemaker or implantable cardioverter defibrillator(ICD), may be a cause for significant complications or unsuccessful implantation. Single lead ICD with atrial sensing dipole(ICD DX) is a safe and functional technology in patients without congenital abnormalities. We provide a review of the literature and a case report of successful implantation of an ICD DX in a patient with LSVC and its efficacy in treating ventricular arrhythmias.

  3. Automated external defibrillators: technical considerations and clinical promise.

    Science.gov (United States)

    Takata, T S; Page, R L; Joglar, J A

    2001-12-04

    Early defibrillation is the most important determinant of survival for victims of cardiac arrest due to ventricular fibrillation. The automated external defibrillator (AED) was developed as the result of the American Heart Association's Public Access Defibrillation initiative. The goal of this initiative is to place AEDs in strategic locations so that laypersons with minimal training could promptly defibrillate victims of cardiac arrest. Because of changes in design and the use of alternative waveforms for defibrillation, the modern AED is compact and portable, simple to use, and highly efficacious; in addition, it requires little maintenance. Automated external defibrillators have been used successfully by traditional and nontraditional responders as well as laypersons. In special environments, such as casinos and commercial aircraft, AEDs have performed particularly well. State and federal legislation has eased concerns about AED use by extending legal protection to AED users under Good Samaritan laws. Since the experience continues to be positive, AEDs are being used in increasingly diverse community locations, and public awareness is growing. The American Heart Association's initiative is progressing rapidly.

  4. Att leva med implanterad defibrillator : En intervjustudie

    OpenAIRE

    Lindner, Lili; Eliasson, Alexandra

    2012-01-01

                                      The study aimed to explore how patients with ICDs experience their quality of life with a focus on everyday life, electric shocks, and how support from the health service is perceived. The studydesign is descriptive with a qualitative approach. Semi-structured interviews were conducted with seven patients. Data collection lasted for three weeks and interviews were conducted in the participant´s homes, at the participants’ workplaces or over the phone. The st...

  5. Referring patients for consideration of device treatment of sudden cardiac death and heart failure: incorporating evidence-based therapies within the Canadian health care system.

    Science.gov (United States)

    Gillis, Anne M

    2005-05-01

    The growing use of the implantable cardioverter defibrillator (ICD) in Canada reflects the impact that primary and secondary prevention trials have had in demonstrating the superiority of the ICD over medical therapy in the prevention of sudden cardiac death in high-risk populations. Currently, there are significant regional disparities in ICD implantation in Canada. These disparities may reflect a lack of regional ICD implant and follow-up programs, and capping of funding for ICDs. In addition to increased funding for ICD systems, more resources are required to perform device implantations and follow patients over the long-term. Potentially eligible patients should be referred to an electrophysiologist for consideration of ICD therapy for the prevention of sudden cardiac death or to an electrophysiologist/ heart failure specialist for the consideration of combination cardiac resynchronization and ICD therapy for the management of refractory heart failure.

  6. Awareness among resident doctors with regards to cardiac defibrillators

    Directory of Open Access Journals (Sweden)

    Garg Rakesh

    2010-01-01

    Full Text Available Background and Aims: Electrical defibrillation is the most important therapy for patients in cardiac arrest. The audit was aimed to assess awareness among residents with respect to routine preuse checking of cardiac defibrillators. Materials and Methods: The audit was conducted at a multispeciality tertiary care referral and teaching center by means of a printed questionnaire from anaesthesiology residents. A database was prepared and responses were analyzed. Results: Eighty resident doctors participated in the audit. Most (97.8% of the residents were sure of the presence of a defibrillator in the operation room (OR; 70% of postgraduates (PGs were aware of the location of the defibrillator in the OR as compared to 83.7% of the senior resident (SRs. Also, 32.1% residents routinely check the availability of a defibrillator. The working condition of the defibrillator was checked by 21.7% of the residents; 25.3% ensured delivery of the set charge. Further, 8.2% of residents ensured availability of both adult and paediatric paddles. About 27.8% of residents ensured the availability of appropriate conducting gel and 53.8% residents were of the opinion that the responsibility of checking the functioning and maintenance of the defibrillators lies with themselves. Some 22% thought that both doctors and technical staff should share the responsibility, while 19.5% opined that it should be the responsibility of the technical staff. Conclusion: All medical equipment is to be tested prior to initial use and periodically thereafter. An extensive, recurring training program, and continued attention to the training of clinical personnel is required to ensure that they are proficient in the operation and testing of specific defibrillator models in their work area. We conclude that apart from awareness of the use of the equipment we are using, its preuse testing is must. All resident doctors should be aware of the presence and adequate functioning of the

  7. Use a defibrillator, save a life

    CERN Multimedia

    Joannah Caborn Wengler

    2012-01-01

    With the work for Long Shutdown 1 looming on the horizon, the CERN Fire Brigade is anticipating a heavy workload: more people working at CERN means more call-outs. So the more trained first-aiders around to help out before the paramedics arrive, the better. Would you know what to do in a medical emergency?   It could happen at any time: two colleagues are having a coffee at work, when one suddenly clutches his or her chest and falls to the floor unconscious. What would you do? Run to find a first-aider? Call the ambulance and wait, finishing your coffee? Neither response is entirely correct. On Monday 11 June in Building 40 the CMS safety group, in collaboration with the Fire Brigade and the Medical Service, demonstrated the recommended, potentially life-saving response to cardiac arrest (see the video), including the correct use of a defibrillator, ten of which were recently installed in key CERN locations (the Bulletin reported).     “In countries where...

  8. Implementation and impact of ICD-10 (Part II

    Directory of Open Access Journals (Sweden)

    Gazanfar Rahmathulla

    2014-01-01

    Full Text Available Background: The transition from the International Classification of Disease-9 th clinical modification to the new ICD-10 was all set to occur on 1 October 2015. The American Medical Association has previously been successful in delaying the transition by over 10 years and has been able to further postpone its introduction to 2015. The new system will overcome many of the limitations present in the older version, thus paving the way to more accurate capture of clinical information. Methods: The benefits of the new ICD-10 system include improved quality of care, potential cost savings, reduction of unpaid claims, and improved tracking of healthcare data. The areas where challenges will be evident include planning and implementation, the cost to transition, a shortage of qualified coders, training and education of the healthcare workforce, and a loss of productivity when this occurs. The impacts include substantial costs to the healthcare system, but the projected long-term savings and benefits will be significant. Improved fraud detection, accurate data entry, ability to analyze cost benefits with procedures, and enhanced quality outcome measures are the most significant beneficial factors with this change. Results: The present Current Procedural Terminology and Healthcare Common Procedure Coding System code sets will be used for reporting ambulatory procedures in the same manner as they have been. ICD-10-PCS will replace ICD-9 procedure codes for inpatient hospital services. The ICD-10-CM will replace the clinical code sets. Our article will focus on the challenges to execution of an ICD change and strategies to minimize risk while transitioning to the new system. Conclusion: With the implementation deadline gradually approaching, spine surgery practices that include multidisciplinary health specialists have to anticipate and prepare for the ICD change in order to mitigate risk. Education and communication is the key to this process in spine

  9. Effect of angiotensin-converting enzyme inhibitors and receptor blockers on appropriate implantable cardiac defibrillator shock in patients with severe systolic heart failure (from the GRADE Multicenter Study).

    Science.gov (United States)

    AlJaroudi, Wael A; Refaat, Marwan M; Habib, Robert H; Al-Shaar, Laila; Singh, Madhurmeet; Gutmann, Rebecca; Bloom, Heather L; Dudley, Samuel C; Ellinor, Patrick T; Saba, Samir F; Shalaby, Alaa A; Weiss, Raul; McNamara, Dennis M; Halder, Indrani; London, Barry

    2015-04-01

    Sudden cardiac death (SCD) is a leading cause of mortality in patients with cardiomyopathy. Although angiotensin-converting enzyme inhibitors (ACEi) and angiotensin receptor blockers (ARBs) decrease cardiac mortality in these cohorts, their role in preventing SCD has not been well established. We sought to determine whether the use of ACEi or ARB in patients with cardiomyopathy is associated with a lower incidence of appropriate implantable cardiac defibrillator (ICD) shocks in the Genetic Risk Assessment of Defibrillator Events study that included subjects with an ejection fraction of ≤30% and ICDs. Treatment with ACEi/ARB versus no-ACEi/ARB was physician dependent. There were 1,509 patients (mean age [SD] 63 [12] years, 80% men, mean [SD] EF 21% [6%]) with 1,213 (80%) on ACEi/ARB and 296 (20%) not on ACEi/ARB. We identified 574 propensity-matched patients (287 in each group). After a mean (SD) of 2.5 (1.9) years, there were 334 (22%) appropriate shocks in the entire cohort. The use of ACEi/ARB was associated with lower incidence of shocks at 1, 3, and 5 years in the matched cohort (7.7%, 16.7%, and 18.5% vs 13.2%, 27.5%, and 32.0%; RR = 0.61 [0.43 to 0.86]; p = 0.005). Among patients with glomerular filtration rate (GFR) >60 and 30 to 60 ml/min/1.73 m(2), those on no-ACEi/ARB were at 45% and 77% increased risk of ICD shock compared with those on ACEi/ARB, respectively. ACEi/ARB were associated with significant lower incidence of appropriate ICD shock in patients with cardiomyopathy and GFR ≥30 ml/min/1.73 m(2) and with neutral effect in those with GFR <30 ml/min/1.73 m(2).

  10. Marketing defibrillation training programs and bystander intervention support.

    Science.gov (United States)

    Sneath, Julie Z; Lacey, Russell

    2009-01-01

    This exploratory study identifies perceptions of and participation in resuscitation training programs, and bystanders' willingness to resuscitate cardiac arrest victims. While most of the study's participants greatly appreciate the importance of saving someone's life, many indicated that they did not feel comfortable assuming this role. The findings also demonstrate there is a relationship between type of victim and bystanders' willingness to intervene. Yet, bystander intervention discomfort can be overcome with cardiopulmonary resuscitation and defibrillation training, particularly when the victim is a coworker or stranger. Further implications of these findings are discussed and modifications to public access defibrillation (PAD) training programs' strategy and communications are proposed.

  11. Diet Survey Of Icds Children In Pune City

    Directory of Open Access Journals (Sweden)

    Pratinidhi A.K

    1998-01-01

    Full Text Available Research question: What is the protein & calorie intake of children getting supplementary nutrition under ICDS? Objectives: I To study the protein and calorie intake of children covered under ICDS. ii To study the protein & caloric content of supplementary nutrition. Study design: Cross- sectional. Setting: ICDS project of Pune city. Participants: Children aged 1-6 years, receiving supplementary nutrition from anganwadis. Sample size: 165 children aged 1-<6 tears. Study variables: Knowledge and perception of ICDS, Protein and calorie intake of children, nutritive value of ICDS supplementary foods. Results: There was a gross deficiency of proteins and calories in majority of the children. The protein and calorie intake was less than 50% of recommended daily allowance in 38.2% and 35.7% children respectively. Only 13.9% of children had a protein intake of ³90% of RDA while 12.7% had a calorie consumption of ³90% of RDA. 71.6% of children aged 3-<6 years took the food to their homes and shared with other family members thus depriving them the total benefit of supplementary nutrition. 46.1% mothers perceived the supplementary nutrition to be a substitude. The supplement given at anganwadi had an average nutritive value of 213 calories and 5.1 gm protein as compared to recommended values of 300 calories & 10 gms protein.

  12. [Functional dysphonia: relation with personality and ICD-10 criteria].

    Science.gov (United States)

    Carvajal, C; Sanfuentes, M T; Eva, P; Jara, C; Lolas Stepke, F

    1992-03-01

    The International Classification of Diseases, 10th. revision (ICD-10) in the category F45 defines the somatoform disorder as a mental disease characterized by the reiterative presentation of somatic symptoms in absence of an organic disease, or the somatic pathology being insufficient to explain the intensity of the symptoms as well as the discomfort and preoccupation of the patient. Fifteen female teachers with functional dysphonia were studied by means of a semistructured interview and psychometric evaluations. Considering dysphonia as the principal symptom, the most frequent diagnosis, in accordance with ICD-10 was "Other somatoform disorder" (F-45.8)(9/15). Five patients were diagnosed as motor dissociative disorder (F-44.4). All the patients had some abnormality of personality (5 with personality disorder and 10 with exacerbation of personality traits). The criteria of ICD-10 to classify the functional dysphonia as Somatoform disorder are discussed. It is suggested that certain personality traits are facilitators for somatization.

  13. Body-focused repetitive behavior disorders in ICD-11

    Directory of Open Access Journals (Sweden)

    Jon E. Grant

    2014-01-01

    Full Text Available This article addresses the question of how body-focused repetitive behavior disorders (e.g., trichotillomania and skin-picking disorder should be characterized in ICD-11. The article reviews the historical nosology of the two disorders and the current approaches in DSM-5 and ICD-10. Although data are limited and mixed regarding the optimal relationship between body-focused repetitive behavior disorders and nosological categories, these conditions should be included within the obsessive-compulsive and related disorders category, as this is how most clinicians see these behaviors, and as this may optimize clinical utility. The descriptions of these disorders should largely mirror those in DSM-5, given the evidence from recent field surveys. The recommendations regarding ICD-11 and body-focused repetitive behavior disorders should promote the global identification and treatment of these conditions in primary care settings.

  14. ICD-10 coding algorithms for defining comorbidities of acute myocardial infarction

    Directory of Open Access Journals (Sweden)

    Evans Dewey

    2006-12-01

    Full Text Available Background With the introduction of ICD-10 throughout Canada, it is important to ensure that Acute Myocardial Infarction (AMI comorbidities employed in risk adjustment methods remain valid and robust. Therefore, we developed ICD-10 coding algorithms for nine AMI comorbidities, examined the validity of the ICD-10 and ICD-9 coding algorithms in detection of these comorbidities, and assessed their performance in predicting mortality. The nine comorbidities that we examined were shock, diabetes with complications, congestive heart failure, cancer, cerebrovascular disease, pulmonary edema, acute renal failure, chronic renal failure, and cardiac dysrhythmias. Methods Coders generated a comprehensive list of ICD-10 codes corresponding to each AMI comorbidity. Physicians independently reviewed and determined the clinical relevance of each item on the list. To ensure that the newly developed ICD-10 coding algorithms were valid in recording comorbidities, medical charts were reviewed. After assessing ICD-10 algorithms' validity, both ICD-10 and ICD-9 algorithms were applied to a Canadian provincial hospital discharge database to predict in-hospital, 30-day, and 1-year mortality. Results Compared to chart review data as a 'criterion standard', ICD-9 and ICD-10 data had similar sensitivities (ranging from 7.1 – 100%, and specificities (above 93.6% for each of the nine AMI comorbidities studied. The frequencies for the comorbidities were similar between ICD-9 and ICD-10 coding algorithms for 49,861 AMI patients in a Canadian province during 1994 – 2004. The C-statistics for predicting 30-day and 1 year mortality were the same for ICD-9 (0.82 and for ICD-10 data (0.81. Conclusion The ICD-10 coding algorithms developed in this study to define AMI comorbidities performed similarly as past ICD-9 coding algorithms in detecting conditions and risk-adjustment in our sample. However, the ICD-10 coding algorithms should be further validated in external databases.

  15. Impact of shocks on mortality in patients with ischemic or dilated cardiomyopathy and defibrillators implanted for primary prevention.

    Directory of Open Access Journals (Sweden)

    Florian Streitner

    Full Text Available BACKGROUND: Emerging interest is seen in the paradox of defibrillator shocks for ventricular tachyarrhythmia and increased mortality risk. Particularly in patients with dilated cardiomyopathy (DCM, the prognostic importance of shocks is unclear. The purpose of this study was to compare the outcome after shocks in patients with ischemic cardiomyopathy (ICM or DCM and defibrillators (ICD implanted for primary prevention. METHODS AND RESULTS: Data of 561 patients were analyzed (mean age 68.6±10.6 years, mean left ventricular ejection fraction 28.6±7.3%. During a median follow-up of 49.3 months, occurrence of device therapies and all-cause mortality were recorded. 74 out of 561 patients (13.2% experienced ≥1 appropriate and 51 out of 561 patients (9.1% ≥1 inappropriate shock. All-cause mortality was 24.2% (136 out of 561 subjects. Appropriate shock was associated with a trend to higher mortality in the overall patient population (HR 1.48, 95% CI 0.96-2.28, log rank p = 0.072. The effect was significant in ICM patients (HR 1.61, 95% CI 1.00-2.59, log rank p = 0.049 but not in DCM patients (HR 1.03, 95% CI 0.36-2.96, log rank p = 0.96. Appropriate shocks occurring before the median follow-up revealed a much stronger impact on mortality (HR for the overall patient population 2.12, 95% CI 1.24-3.63, p = 0.005. The effect was driven by ICM patients (HR 2.48, 95% CI 1.41-4.37, p = 0.001, as appropriate shocks again did not influence survival of DCM patients (HR 0.63, 95% CI 0.083-4.75, p = 0.65. Appropriate shocks occurring after the median follow-up and inappropriate shocks occurring at any time revealed no impact on survival in any of the groups (p = ns. CONCLUSION: Appropriate shocks are associated with reduced survival in patients with ICM but not in patients with DCM and ICDs implanted for primary prevention. Furthermore, the negative effect of appropriate shocks on survival in ICM patients is only evident within the

  16. Advantage of four-electrode over two-electrode defibrillators

    Science.gov (United States)

    Bragard, J.; Šimić, A.; Laroze, D.; Elorza, J.

    2015-12-01

    Defibrillation is the standard clinical treatment used to stop ventricular fibrillation. An electrical device delivers a controlled amount of electrical energy via a pair of electrodes in order to reestablish a normal heart rate. We propose a technique that is a combination of biphasic shocks applied with a four-electrode system rather than the standard two-electrode system. We use a numerical model of a one-dimensional ring of cardiac tissue in order to test and evaluate the benefit of this technique. We compare three different shock protocols, namely a monophasic and two types of biphasic shocks. The results obtained by using a four-electrode system are compared quantitatively with those obtained with the standard two-electrode system. We find that a huge reduction in defibrillation threshold is achieved with the four-electrode system. For the most efficient protocol (asymmetric biphasic), we obtain a reduction in excess of 80% in the energy required for a defibrillation success rate of 90%. The mechanisms of successful defibrillation are also analyzed. This reveals that the advantage of asymmetric biphasic shocks with four electrodes lies in the duration of the cathodal and anodal phase of the shock.

  17. 21 CFR 870.5310 - Automated external defibrillator.

    Science.gov (United States)

    2010-04-01

    ... device with a rhythm recognition detection system that delivers into a 50 ohm test load an electrical shock of a maximum of 360 joules of energy used for defibrillating (restoring normal heart rhythm) the atria or ventricles of the heart. An AED analyzes the patient's electrocardiogram, interprets...

  18. Hvor er den automatiske eksterne defibrillator? Udvikling og uddannelse

    DEFF Research Database (Denmark)

    Løfgren, Bo; Grove, Erik; Krarup, Niels Henrik

    2009-01-01

    The International Liaison Committee on Resuscitation has presented a universal sign to indicate the presence of automated external defibrillators (AED). To disseminate the knowledge of this important signage, a review in a Danish context is presented. It is essential that the public in general...

  19. Time to choose – DSM-5, ICD-11 or both?

    Directory of Open Access Journals (Sweden)

    Tyrer, Peter

    2014-09-01

    Full Text Available DSM-5 was published in May 2013, and ICD 11 is not due to be published until the end of 2015 at the earliest. Nevertheless, it is possible to make a comparison at this early stage as much of the main decisions have been made with both classifications. DSM-5 aimed to make a paradigm shift by providing objective, independent measures of classification, but in this respect it clearly failed. It did respond to previous criticisms that there were too many diagnoses in the classification and that eliminated some conditions in favour of larger groupings (eg, autism spectrum disorder, but it has still come in for heavy criticism. ICD 11 deviates from DSM-5 in radically different classifications of personality and stress disorders and in general has pursued a different pathway, concentrating on clinical utility as the main guide to the classification. It is up to practitioners to choose which they prefer, but ICD 11 will be in a much stronger position than ICD 10 was when it was published in 1999.

  20. Psychotic disorders in DSM-5 and ICD-11.

    Science.gov (United States)

    Biedermann, Falko; Fleischhacker, W Wolfgang

    2016-08-01

    The Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) was published by the American Psychiatric Association (APA) in 2013, and the Work Group on the Classification of Psychotic disorders (WGPD), installed by the World Health Organization (WHO), is expected to publish the new chapter about schizophrenia and other primary psychotic disorders in 2017. We reviewed the available literature to summarize the major changes, innovations, and developments of both manuals. If available and possible, we outline the theoretical background behind these changes. Due to the fact that the development of ICD-11 has not yet been completed, the details about ICD-11 are still proposals under ongoing revision. In this ongoing process, they may be revised and therefore have to be seen as proposals. DSM-5 has eliminated schizophrenia subtypes and replaced them with a dimensional approach based on symptom assessments. ICD-11 will most likely go in a similar direction, as both manuals are planned to be more harmonized, although some differences will remain in details and the conceptual orientation. Next to these modifications, ICD-11 will provide a transsectional diagnostic criterion for schizoaffective disorders and a reorganization of acute and transient psychotic and delusional disorders. In this manuscript, we will compare the 2 classification systems.

  1. 77 FR 8877 - ICD-9-CM Coordination and Maintenance (C&M) Committee Meeting

    Science.gov (United States)

    2012-02-15

    ... HUMAN SERVICES Centers for Disease Control and Prevention ICD-9-CM Coordination and Maintenance (C&M... Standards Staff, announces the following meeting. Name: ICD-9-CM Coordination and Maintenance (C&M... ), for questions about the registration process. Purpose: The ICD-9-CM Coordination and...

  2. Risk factors and the effect of cardiac resynchronization therapy on cardiac and non-cardiac mortality in MADIT-CRT

    DEFF Research Database (Denmark)

    Perkiomaki, Juha S; Ruwald, Anne-Christine; Kutyifa, Valentina;

    2015-01-01

    causes, 108 (63.9%) deemed cardiac, and 61 (36.1%) non-cardiac. In multivariate analysis, increased baseline creatinine was significantly associated with both cardiac and non-cardiac deaths [hazard ratio (HR) 2.97, P ...AIMS: To understand modes of death and factors associated with the risk for cardiac and non-cardiac deaths in patients with cardiac resynchronization therapy with implantable cardioverter-defibrillator (CRT-D) vs. implantable cardioverter-defibrillator (ICD) therapy, which may help clarify...... the action and limitations of cardiac resynchronization therapy (CRT) in relieving myocardial dysfunction. METHODS AND RESULTS: In Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT), during 4 years of follow-up, 169 (9.3%) of 1820 patients died of known...

  3. Management of Cardiac Electronic Device Infections

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nielsen, Jens Cosedis

    2016-01-01

    Cardiac implantable electronic device (CIED) infection is an increasing problem. Reasons for this are uncertain, but likely relate to an increasing proportion of implantable cardioverter defibrillator (ICD) and cardiac resynchronisation therapy (CRT) devices implanted, as well as implantations...... in 'higher risk' candidates, i.e. patients with heart failure, diabetes and renal failure. Challenges within the field of CIED infections are multiple with prevention being the most important challenge. Careful prescription of CIED treatment and careful patient preparation before implantation is important...

  4. The Cause and Mechanism of Cardiac Electrical Instability. Defibrillation Mechanism

    Directory of Open Access Journals (Sweden)

    Rustam G. Habchabov

    2012-06-01

    Full Text Available The reason for the ominous arrhythmias pathway, causing sudden somatic death from cardiovascular diseases is still not clear, cardiological examinations of this phenomenon are conducted throughout the world. Laceration of connective insulating tissue membrane of heart pathway with ectopic nodes oxidation may cause ominous arrhythmias; nobody has considered this cause as a cardiac electrical instability before. Defibrillator electric discharges cannot penetrate into myocardium due to the connective insulating tissue membrane, nobody has considered nervous system, transmitting electricity.

  5. The role of automated external defibrillators in dental practice.

    Science.gov (United States)

    Boyd, Barry C; Fantuzzo, Joseph J; Votta, Timothy

    2006-01-01

    Dental practices are seeing an increasing number of elderly and medically compromised patients, making it likely that staff will be called upon to respond to medical emergencies in the office, including cardiac arrest. Out-of-hospital cardiac arrests account for nearly half of all cardiovascular deaths in the United States. In adult cardiac arrest victims, the most frequent cause of sudden cardiac arrest is ventricular dysrhythmia, either ventricular tachycardia or ventricular fibrillation. The survival rate for sufferers of out-of-hospital cardiac arrests is a dismal 1% to 5% to hospital discharge. A majority of people who survive to discharge sustain significant morbidity. Untreated ventricular fibrillation degenerates into asystole, which is often refractory to resuscitative efforts and represents a terminal event. The development and availability of the automated external defibrillator (AED) represents a promising advance in the pre-hospital early defibrillation of victims of sudden cardiac arrest in a variety of settings, often remote from hospitals or EMS personnel. Given the medically compromised segment of the population treated in many dental practices today, it is imperative that dental practitioners and allied health providers become trained in the recognition and prompt initiation of emergency care, including basic life support with early defibrillation. The AED is becoming more accessible, with increasingly widespread availability, training in its use and relative ease of operation, making the goal of increased survival one in which dental health professionals can play a part.

  6. Clinical management of electromagnetic interferences in patients with pacemakers and implantable cardioverter-defibrillators: review of the literature and focus on magnetic resonance conditional devices.

    Science.gov (United States)

    Corzani, Alessandro; Ziacchi, Matteo; Biffi, Mauro; Allaria, Luca; Diemberger, Igor; Martignani, Cristian; Bratten, Tara; Gardini, Beatrice; Boriani, Giuseppe

    2015-10-01

    The number of cardiac implantable electronic devices (CIEDs) has greatly increased in the last 10 years. Many electronic devices used in daily activities generate electromagnetic interferences (EMIs) that can interact with CIEDs. In clinical practice, it is very important to know the potential sources of EMIs and their effect on CIEDs in order to understand how to manage or mitigate them. A very important source of EMI is magnetic resonance (MR), which is considered nowadays the diagnostic gold standard for different anatomical districts. In this review, we focused on the effects of EMI on CIEDs and on the clinical management. Moreover, we made a clarification about MR and CIEDs.In patients with CIEDs, EMIs may cause potentially serious and even life-threatening complications (inappropriate shocks, device malfunctions, inhibition of pacing in pacemaker-dependent patients) and may rarely dictate device replacement. The association of inappropriate shocks with increased mortality highlights the importance of minimizing the occurrence of EMI. Adequate advice and recommendations about the correct management of EMIs in patients with CIEDs are required to avoid all complications during hospitalization and in daily life. Furthermore, the article focused on actual management about MR and CIEDs.

  7. Potential demographic and baselines variables for risk stratification of high-risk post-myocardial infarction patients in the era of implantable cardioverter-defibrillator - a prognostic indicator

    DEFF Research Database (Denmark)

    Yap, Yee Guan; Duong, Trinh; Bland, Martin;

    2008-01-01

    , sex, previous MI or angina, hypertension, diabetes, systolic blood pressure, heart rate, NYHA functional class and non-Q wave infarct on electrocardiogram. Distinct survival curves were obtained for 3 risk groups based on the median and inter-quartile range for the prognostic index. In the high...

  8. The CopenHeartSF trial—comprehensive sexual rehabilitation programme for male patients with implantable cardioverter defibrillator or ischaemic heart disease and impaired sexual function

    DEFF Research Database (Denmark)

    Johansen, Pernille Palm; Zwisler, Ann-Dorthe; Svendsen, Jesper Hastrup

    2013-01-01

    and depression. Treatment and care possibilities seem to be lacking. Studies indicate that non-pharmacological interventions such as exercise training and psychoeducation possess the potential of reducing sexual dysfunction in patients with heart disease. The CopenHeartSF trial will investigate the effect......Sexuality is an important part of people's physical and mental health. Patients with heart disease often suffer from sexual dysfunction. Sexual dysfunction has a negative impact on quality of life and well-being in persons with heart disease, and sexual dysfunction is associated with anxiety...

  9. Transthoracic electrical impedance during external defibrillation: comparison of measured and modelled waveforms.

    Science.gov (United States)

    Al Hatib, F; Trendafilova, E; Daskalov, I

    2000-02-01

    The transthoracic electrical impedance is an important defibrillation parameter, affecting the defibrillating current amplitude and energy, and therefore the defibrillation efficiency. A close relationship between transthoracic impedance and defibrillation success rate was observed. Pre-shock measurements (using low amplitude high frequency current) of the impedance were considered a solution for selection of adequate shock voltages or for current-based defibrillation dosage. A recent approach, called 'impedance-compensating defibrillation' was implemented, where the pulse duration was controlled with respect to the impedance measured during the initial phase of the shock. These considerations raised our interest in reassessment of the transthoracic impedance characteristics and the corresponding measurement methods. The purpose of this work is to study the variations of the transthoracic impedance by a continuous measurement technique during the defibrillation shock and comparing the data with results obtained by modelling. Voltage and current impulse waveforms were acquired during cardioversion of patients with atrial fibrillation or flutter. The same type of defibrillation pulse was taken from dogs after induction of fibrillation. The electrodes were located in the anterior position, for both the patients and animals.

  10. High-dose lidocaine does not affect defibrillation efficacy: implications for defibrillation mechanisms.

    Science.gov (United States)

    Ujhelyi, M R; Sims, J J; Miller, A W

    1998-04-01

    This study assessed the effect of low (10 mg.kg-1.h-1) and very high (18 mg.kg-1.h-1) doses of lidocaine on defibrillation energy requirements (DER) to relate changes in indexes of sodium-channel blockade with changes in DER values using a dose-response study design. In group 1 (control; n = 6 pigs), DER values were determined at baseline and during treatment with 5% dextrose in water (D5W) and with D5W added to D5W. In group 2 (n = 7), DER values were determined at baseline and during treatment with low-dose lidocaine followed by high-dose lidocaine. In group 3 (n = 3), DER values were determined at baseline and high-dose lidocaine. Group 3 controlled for the order of lidocaine treatment with the addition of high-dose lidocaine after baseline. DER values in group 1 did not change during D5W. In group 2, low-dose lidocaine increased DER values by 51% (P = 0.01), whereas high-dose lidocaine added to low-dose lidocaine reduced DER values back to within 6% of baseline values (P = 0.02, low dose vs. high dose). DER values during high-dose lidocaine in group 3 also remained near baseline values (16.2 +/- 2.7 to 12.9 +/- 2.7 J), demonstrating that treatment order had no impact on group 2. Progressive sodium-channel blockade was evident as incremental reduction in ventricular conduction velocity as the lidocaine dose increased. Lidocaine also significantly increased ventricular fibrillation cycle length as the lidocaine dose increased. However, the greatest increase in DER occurred when ventricular fibrillation cycle length was minimally affected, demonstrating a negative correlation (P = 0.04). In summary, lidocaine has an inverted U-shaped DER dose-response curve. At very high lidocaine doses, DER values are similar to baseline and tend to decrease rather than increase. Increased refractoriness during ventricular fibrillation may be the electrophysiological mechanism by which high-dose lidocaine limits the adverse effects that low-dose lidocaine has on DER values

  11. ICD-10: are you ready for a brave new world?

    Science.gov (United States)

    Cannon, Barbara A; Strubler, Diana L

    2014-09-01

    The ICD-10 transition will be an evolutionary process. Relying on the EHR or certified coding staff alone will not be sufficient. The EHR can facilitate easy search tools that assist the provider in selecting a diagnosis. Billing staff are an invaluable resource to help validate that coding and documentation are in sync but the burden will clearly rest on the provider. The provider will be juggling a new code structure, drilling down to new levels of complexity and ensuring their documentation supports the specificity of the new codes selected, all while managing a full patient schedule. Education for the provider will be of paramount importance as they navigate this brave new world.

  12. Disorders related to sexuality and gender identity in the ICD-11: revising the ICD-10 classification based on current scientific evidence, best clinical practices, and human rights considerations.

    Science.gov (United States)

    Reed, Geoffrey M; Drescher, Jack; Krueger, Richard B; Atalla, Elham; Cochran, Susan D; First, Michael B; Cohen-Kettenis, Peggy T; Arango-de Montis, Iván; Parish, Sharon J; Cottler, Sara; Briken, Peer; Saxena, Shekhar

    2016-10-01

    In the World Health Organization's forthcoming eleventh revision of the International Classification of Diseases and Related Health Problems (ICD-11), substantial changes have been proposed to the ICD-10 classification of mental and behavioural disorders related to sexuality and gender identity. These concern the following ICD-10 disorder groupings: F52 Sexual dysfunctions, not caused by organic disorder or disease; F64 Gender identity disorders; F65 Disorders of sexual preference; and F66 Psychological and behavioural disorders associated with sexual development and orientation. Changes have been proposed based on advances in research and clinical practice, and major shifts in social attitudes and in relevant policies, laws, and human rights standards. This paper describes the main recommended changes, the rationale and evidence considered, and important differences from the DSM-5. An integrated classification of sexual dysfunctions has been proposed for a new chapter on Conditions Related to Sexual Health, overcoming the mind/body separation that is inherent in ICD-10. Gender identity disorders in ICD-10 have been reconceptualized as Gender incongruence, and also proposed to be moved to the new chapter on sexual health. The proposed classification of Paraphilic disorders distinguishes between conditions that are relevant to public health and clinical psychopathology and those that merely reflect private behaviour. ICD-10 categories related to sexual orientation have been recommended for deletion from the ICD-11.

  13. 77 FR 48985 - Notice of Meeting of the ICD-9-CM Coordination and Maintenance Committee

    Science.gov (United States)

    2012-08-15

    ... ICD-10-CM Diagnosis Topics: Age related macular degeneration Bilateral mononeuropathy Bilateral option for cerebrovascular codes Chronic Fatigue Syndrome Complications of urinary devices Diabetic...

  14. Reliability of clinical ICD-10 diagnoses among electroconvulsive therapy patients with chronic affective disorders

    DEFF Research Database (Denmark)

    Jakobsen, Klaus Damgaard; Hansen, Thomas Folkmann; Dam, Henrik;

    2008-01-01

    ICD-10, OPCRIT ICD-10 and DSM-IV diagnoses were determined using unweighted K-statistics. Results: The sensitivity, specificity, positive and negative predictive values of the clinical bipolar diagnoses was 0.55, 0.75, 0.42 and 0.84, respectively. The sensitivity, specificity, positive and negative...... = 0.35. The agreement between OPCRIT ICD-10 and DSM-IV diagnoses, on bipolar vs. non-bipolar disorders was high, K = 0.91, and the agreement on unipolar vs. non-unipolar disorders was fairly high, K = 0.78. Conclusions: This study demonstrates that the reliability of clinical ICD-10 diagnoses...

  15. 76 FR 51985 - ICD-9-CM Coordination and Maintenance Committee Meeting

    Science.gov (United States)

    2011-08-19

    ... Implantable meshes. ICD-10-CM Diagnosis Topics Aggressive periodontitis. Chronic Fatigue Syndrome. Chronic periodontitis. Gingival recession. Agenda items are subject to change as priorities dictate. Note: CMS and...

  16. International Database events common cause failure (ICDE); Banco de datos internacional de sucesos de fallo de causa comun (ICDE)

    Energy Technology Data Exchange (ETDEWEB)

    Morales, M. R.; Fernandez Andujar, B.; Pereira, M. B.

    2013-09-01

    A Common Cause Failure (CCF) is a dependent event in which two or more components fail simultaneously or short space of time as a direct result of a shared common cause. The shared cause may be functional or physical. Due to the low frequency of this type of events, some Member States of the Agency of Nuclear Energy (NEA) of the Organization for Cooperation and Economic Development (OECD) decided to create the project International Common-Cause Failure Data Exchange (ICDE) in order to encourage multilateral cooperation in the collection and analysis of data relating to CCF events. (Author)

  17. Anatomy of the ICDS series: A bibliometric analysis

    Science.gov (United States)

    Cardona, Manuel; Marxa, Werner

    2007-12-01

    In this article, the proceedings of the International Conferences on Defects in Semiconductors (ICDS) have been analyzed by bibliometric methods. The papers of these conferences have been published as articles in regular journals or special proceedings journals and in books with diverse publishers. The conference name/title changed several times. Many of the proceedings did not appear in the so-called “source journals” covered by the Thomson/ISI citation databases, in particular by the Science Citation Index (SCI). But the number of citations within these source journals can be determined using the Cited Reference Search mode under the Web of Science (WoS) and the SCI offered by the host STN International. The search functions of both systems were needed to select the papers published as different document types and to cover the full time span of the series. The most cited ICDS papers were identified, and the overall numbers of citations as well as the time-dependent impact of these papers, of single conferences, and of the complete series, was established. The complete of citing papers was analyzed with respect to the countries of the citing authors, the citing journals, and the ISI subject categories.

  18. Anatomy of the ICDS series: A bibliometric analysis

    Energy Technology Data Exchange (ETDEWEB)

    Cardona, Manuel [Max Planck Institute for Solid State Research, Heisenbergstrasse 1, D-70569 Stuttgart (Germany)], E-mail: m.cardona@fkf.mpg.de; Marx, Werner [Max Planck Institute for Solid State Research, Heisenbergstrasse 1, D-70569 Stuttgart (Germany)

    2007-12-15

    In this article, the proceedings of the International Conferences on Defects in Semiconductors (ICDS) have been analyzed by bibliometric methods. The papers of these conferences have been published as articles in regular journals or special proceedings journals and in books with diverse publishers. The conference name/title changed several times. Many of the proceedings did not appear in the so-called 'source journals' covered by the Thomson/ISI citation databases, in particular by the Science Citation Index (SCI). But the number of citations within these source journals can be determined using the Cited Reference Search mode under the Web of Science (WoS) and the SCI offered by the host STN International. The search functions of both systems were needed to select the papers published as different document types and to cover the full time span of the series. The most cited ICDS papers were identified, and the overall numbers of citations as well as the time-dependent impact of these papers, of single conferences, and of the complete series, was established. The complete of citing papers was analyzed with respect to the countries of the citing authors, the citing journals, and the ISI subject categories.

  19. ICD 10 Based Medical Expert System Using Fuzzy Temporal Logic

    Directory of Open Access Journals (Sweden)

    P.Chinniah

    2009-12-01

    Full Text Available Medical diagnosis process involves many levels and considerable amount of time and money are invariably spent for the first level of diagnosis usually made by the physician for all the patients every time. Hence there is a need for a computer based system which not only asks relevant questions to the patients but also aids the physician by giving a set of possible diseases from the symptoms obtained using logic at inference. In this work, an ICD10 based Medical Expert System that provides advice, information and recommendation to the physician using fuzzy temporal logic. The knowledge base used in this system consists of facts of symptoms and rules on diseases. It also provides fuzzy severity scale and weight factor for symptom and disease and can vary with respect to time. The system generates the possible disease conditions based on modified Euclidean metric using Elder’s algorithm for effective clustering. The minimum similarity value is used as the decision parameter to identify a disease. Keywords -Fuzzy clustering, symptoms, fuzzy severity scale, weight factor, Minkowski distance, ICD, WHO, Rules Base, TSQL

  20. Automated external defibrillators in the Australian fitness industry.

    Science.gov (United States)

    Norton, Kevin I; Norton, Lynda H

    2008-04-01

    Sudden cardiac arrest (SCA) occurs in many thousands of Australians each year. Scientific evidence shows an increased survival rate for individuals who receive electrical defibrillation in the first few minutes after SCA. In the last decade automated (rhythm-detecting) external defibrillators (AEDs) have become available that are portable and affordable. Although still relatively rare, there is still the potential that SCA may occur when a person undertakes physical activity. Consequently, health/fitness centres are increasingly recognised as higher risk sites that may benefit from placement of AEDs. There are no laws in Australia requiring health/fitness centres to install AEDs. However, several international and professional organisations have "strongly encouraged" larger centres to install AEDs. Guidelines and algorithms are presented to help estimate the risk of SCA in fitness centres. Fitness centre placement is particularly important if the clientele is older or has a 'high-risk' profile, for example, clients with cardiovascular, respiratory or metabolic disease. International negligence case law and duty of care principles suggests the standard of care required in health/fitness centres may be increasing. Therefore, it may be prudent to install AEDs in larger centres and those in which higher risk groups are physically active.

  1. Apical aneurysm and myocardial bridging in a patient with hypertrophic cardiomyopathy: association or consequence of the myocardial bridging?

    Science.gov (United States)

    Foucault, Anthony; Hilpert, Loic; Hédoire, Francois; Saloux, Eric; Gomes, Sophie; Pellissier, Arnaud; Scanu, Patrice; Champ-Rigot, Laure; Milliez, Paul

    2012-01-01

    The identification of high-risk patients with hypertrophic cardiomyopathy (HC) for primary prevention of sudden cardiac death (SCD) remains a challenging issue, since major risk factors sometimes lack specificity. We report the case of a patient with HC and association of apical aneurysm and myocardial bridging who had been initially not implanted because she had only one major risk factor. She subsequently experienced a sustained ventricular tachycardia that finally motivated the implantation. We conclude that it is never an easy decision to implant a preventive implantable cardioverter-defibrillator (ICD). Nevertheless, additional criteria for a better selection of patients who would benefit from an ICD implant are certainly useful.

  2. Catheter ablation of a monofocal premature ventricular complex triggering idiopathic ventricular fibrillation.

    Science.gov (United States)

    Takatsuki, S; Mitamura, H; Ogawa, S

    2001-07-01

    A 62 year old man was admitted for evaluation of recurrent episodes of syncope. A surface ECG showed frequent repetitive premature ventricular complexes of right ventricular outflow tract origin. Ventricular fibrillation was inducible by programmed electrical stimulation but otherwise cardiac evaluation was unremarkable. A diagnosis of idiopathic ventricular fibrillation was made and an implantable cardioverter-defibrillator (ICD) was installed. However, spontaneous ventricular fibrillation recurred, requiring repeated ICD discharges. The ventricular fibrillation was reproducibly triggered by a single premature ventricular complex with a specific QRS morphology. Radiofrequency catheter ablation was carried out to eradicate this complex. No ventricular fibrillation has developed after this procedure, and the patient does not require drug treatment.

  3. Infective endocarditis and risk of death after cardiac implantable electronic device implantation

    DEFF Research Database (Denmark)

    Özcan, Cengiz; Raunsø, Jakob; Lamberts, Morten;

    2017-01-01

    AIMS: To determine the incidence, risk factors, and mortality of infective endocarditis (IE) following implantation of a first-time, permanent, cardiac implantable electronic device (CIED). METHODS AND RESULTS: From Danish nationwide administrative registers (beginning in 1996), we identified all...... de-novo permanent pacemakers (PMs) and implantable cardioverter defibrillators (ICDs) together with the occurrence of post-implantation IE-events in the period from 2000-2012. Included were 43 048 first-time PM/ICD recipients. Total follow-up time was 168 343 person-years (PYs). The incidence rate...

  4. A viewpoint on the impact of device advisories on patient-centered outcomes

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van den Berg, Martha; Theuns, Dominic A M J

    2009-01-01

    Device advisories due to potential hardware failure comprise one of the downsides of implantable cardioverter defibrillator (ICD) therapy. The impact of advisories on patient-centered outcomes has largely been overlooked. We examined the impact of ICD advisories on patient-centered outcomes via....... The sample size across studies varied between 30 and 86 patients subject to an advisory; four of six studies used a case-control design and two of six a prospective study design. There was considerable variability between notification of the advisory and assessment of the patient-centered outcomes, ranging...

  5. ICD-10在中国的引进和推广%Introduction and Promotion of ICD-10 in China

    Institute of Scientific and Technical Information of China (English)

    于欣

    2009-01-01

    在1948年世界卫生组织出版的《国际疾病分类第六版》中,精神障碍被首次纳入。在1975年颁布ICD-9后,WHO着手开始ICD-10的筹备工作。筹备工作是以几项重大的科研计划开展为标志的:①编制了“复合性国际诊断交谈检查(CIDI)”,适用于在不同国家的一般人群中进行精神障碍的流行病学研究,目前CIDI的版本已经更新到3.0;②编制了适用于临床工作者使用的评定工具“神经精神病学临床评定表(SCAN)”,用于专业人员临床评估病人;③编制了适用于不同国家的人格障碍评定工具“国际人格障碍检查”(International Personality Disorder Examination,IPDE)。

  6. Preparing for ICD-10-CM/PCS implementation: impact on productivity and quality.

    Science.gov (United States)

    Stanfill, Mary H; Hsieh, Kang Lin; Beal, Kathleen; Fenton, Susan H

    2014-01-01

    Coding productivity is expected to drop significantly during the lead-up to and in the initial stages of ICD-10-CM/PCS implementation, now expected to be delayed until October 1, 2015. This study examined the differences in coding productivity between ICD-9-CM and ICD-10-CM/PCS for hospital inpatient cases matched for complexity and severity. Additionally, interrater reliability was calculated to determine the quality of the coding. On average, coding of an inpatient record took 17.71 minutes (69 percent) longer with ICD-10-CM/PCS than with ICD-9-CM. A two-tailed T-test for statistical validity for independent samples was significant (p = .001). No coder characteristics such as years of experience or educational level were found to be a significant factor in coder productivity. Coders who had received more extensive training were faster than coders who had received only basic training. Though this difference was not statistically significant, it provides a strong indication of significant return on investment for staff training time. Coder interrater reliability was substantial for ICD-9-CM but only moderate for ICD-10-CM/PCS, though some ICD-10-CM/PCS cases had complete interrater (coder) agreement. Time spent coding a case was negatively correlated with interrater reliability (-0.425 for ICD-10-CM and -0.349 for ICD-10-PCS). This finding signals that increased time per case does not necessarily translate to higher quality. Adequate training for coders, as well as guidance regarding time invested per record, is important. Additionally, these findings indicate that previous estimates of initial coder productivity loss with ICD-10-CM/PCS may have been understated.

  7. Trends in Gastroenteritis-associated Mortality in the United States 1985-2005: Variations by ICD-9 and ICD-10 Codes

    Science.gov (United States)

    BackgroundTrends in gastroenteritis-associated mortality are changing over time with development of antibiotic resistant strains of certain pathogens, improved diagnostic methods, and changing healthcare. In 1999, ICD-10 coding was introduced for mortality records which can also ...

  8. Estimation of the Alpha Factor Parameters Using the ICDE Database

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Dae Il; Hwang, M. J.; Han, S. H

    2007-04-15

    Detailed common cause failure (CCF) analysis generally need for the data for CCF events of other nuclear power plants because the CCF events rarely occur. KAERI has been participated at the international common cause failure data exchange (ICDE) project to get the data for the CCF events. The operation office of the ICDE project sent the CCF event data for EDG to the KAERI at December 2006. As a pilot study, we performed the detailed CCF analysis of EDGs for Yonggwang Units 3 and 4 and Ulchin Units 3 and 4 using the ICDE database. There are two onsite EDGs for each NPP. When an offsite power and the two onsite EDGs are not available, one alternate AC (AAC) diesel generator (hereafter AAC) is provided. Two onsite EDGs and the AAC are manufactured by the same company, but they are designed differently. We estimated the Alpha Factor and the CCF probability for the cases where three EDGs were assumed to be identically designed, and for those were assumed to be not identically designed. For the cases where three EDGs were assumed to be identically designed, double CCF probabilities of Yonggwang Units 3/4 and Ulchin Units 3/4 for 'fails to start' were estimated as 2.20E-4 and 2.10E-4, respectively. Triple CCF probabilities of those were estimated as 2.39E-4 and 2.42E-4, respectively. As each NPP has no experience for 'fails to run', Yonggwang Units 3/4 and Ulchin Units 3/4 have the same CCF probability. The estimated double and triple CCF probabilities for 'fails to run' are 4.21E-4 and 4.61E-4, respectively. Quantification results show that the system unavailability for the cases where the three EDGs are identical is higher than that where the three EDGs are different. The estimated system unavailability of the former case was increased by 3.4% comparing with that of the latter. As a future study, a computerization work for the estimations of the CCF parameters will be performed.

  9. 应用 ICD 编码提高入出院诊断符合率%Improve the Accuracy of Diagnosis Coincidence Rate by ICD

    Institute of Scientific and Technical Information of China (English)

    王志国; 朱佳怀; 邹郢; 黄丽丽; 朱智明

    2015-01-01

    Objective The aim is to improve the accuracy of diagnosis coincidence rate with ICD assis -tance judgment.Methods The data of diagnosis were extracted from Hospital Information System .The difference between physician judgment and ICD code judgment was compared , the inconsistent cases were analyzed .Results The coincidence rate judged by ICD code was higher than that judged by physician (99.21% vs.54.31%,P <0.0001).Of all the 2145 cases, 70 cases judged by physician were wrong .Conclusion With the assistance judg-ment of ICD can improve the accuracy of diagnosis coincidence rate .%目的:以国际疾病分类编码(ICD10)辅助判定提高患者出入院诊断符合率的准确性。方法从“军字一号”数据库中提取诊断符合相关数据,比较医师判定和 ICD10判定入院诊断符合的一致性,并对两种判定不一致的病例进行分析。结果2145例次出院患者的 ICD 编码诊断符合率判定(99.21%)明显高于医师判定(54.31%,P <0.0001),有70例为医师判定错误。结论以 ICD 编码进行辅助判定,有助于提高患者入出院诊断符合率的准确性,提高诊断质量。

  10. Wavelength sensitive detector based on ICD in two coupled quantum wells

    Science.gov (United States)

    Goldzak, Tamar; Gilary, Ido; Moiseyev, Nimrod

    2014-05-01

    We design a wavelength sensitive detector based on inter coulombic decay (ICD) mechanism in a two-quantum well nano-structure. The two coupled quantum wells are designed to satisfy the specific conditions which allow the ICD to occur. In this setup, by absorbing light an electron in one well is excited. Its relaxation back to the ground state is a non-radiative process which transfers the excess energy to the ionization of the electron in the neighboring well into the continuum. Only radiation with a specific wavelength will be absorbed, when the wavelength matches the excitation energy in the quantum well. By applying a weak bias a current is obtained even when light with a very low intensity is absorbed. For the ICD to be dominant decay mechanism it must prevail over all other possible competitive decay processes. We have found that the lifetime of the ICD is on the timescale of picoseconds. Control over the ICD lifetime can be achieved by variation of different parameters in the two quantum well nano-structure. The most useful parameter is the distance between the two quantum wells. We show that as the distance decreases the decay rate of the ICD increases. Furthermore the distance can be tuned such that the emitted electron would be in a metastable state in the continuum (a resonance state); this causes the life time of the ICD to be an order of magnitude smaller, and improves the efficiency of the ICD.

  11. What happened to harmonization of the PTSD diagnosis? The divergence of ICD11 and DSM5.

    Science.gov (United States)

    Bisson, J I

    2013-09-01

    The development of ICD11 and DSM5 was seen as an opportunity to harmonize the two major classification systems for mental disorders. The proposed ICD11 and DSM5 diagnostic criteria for PTSD are markedly different. The implications of this remain to be seen, but have the potential to cause confusion to PTSD sufferers, clinicians, researchers and others impacted on by the condition.

  12. ICD 10 Based Medical Expert System Using Fuzzy Temporal Logic

    CERN Document Server

    Chinniah, P

    2010-01-01

    Medical diagnosis process involves many levels and considerable amount of time and money are invariably spent for the first level of diagnosis usually made by the physician for all the patients every time. Hence there is a need for a computer based system which not only asks relevant questions to the patients but also aids the physician by giving a set of possible diseases from the symptoms obtained using logic at inference. In this work, an ICD10 based Medical Expert System that provides advice, information and recommendation to the physician using fuzzy temporal logic. The knowledge base used in this system consists of facts of symptoms and rules on diseases. It also provides fuzzy severity scale and weight factor for symptom and disease and can vary with respect to time. The system generates the possible disease conditions based on modified Euclidean metric using Elders algorithm for effective clustering. The minimum similarity value is used as the decision parameter to identify a disease.

  13. On the road to DSM-V and ICD-11.

    Science.gov (United States)

    Kupfer, David J; Regier, Darrel A; Kuhl, Emily A

    2008-11-01

    Development of the fifth edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-V) has been ongoing since 1994, though official release will not occur for another 4 years. Potential revisions are being derived from multiple sources, including building on perceived limitations of DSM-IV; broad-based literature reviews; secondary and primary data analyses; and discussions between global members of the mental health community. The current focus on aligning DSM with the International Classification of Diseases-11 (ICD-11) speaks to the importance of creating a unified text that embraces cross-cutting issues of diagnostics, such as developmental, age-related, and cultural phenomena. International discourse is vital to this process and has been fostered by a National Institutes of Health-sponsored conference series on diagnosis-specific topics. From this series, the DSM-V Task Force developed the following set of revision principals to guide the efforts of the DSM-V Work Groups: grounding recommendations in empirical evidence; maintaining continuity with previous editions of DSM; removing a priori limitations on the amount of changes DSM-V may incur; and maintaining DSM's status as a living document. With work group formation complete, members are currently carrying out the research and revision recommendations proposed during the conference series. Ongoing activities include adding specialized advisors to each work group; completing literature reviews and planning data analyses; and forming study groups to discuss integration of cross-cutting issues (e.g., developmental lifespan factors; formation of diagnostic spectra). The road to DSM-V and ICD-11 has been challenging, but members continue to work diligently in their goal of constructing the most harmonious, scientifically sound, and clinically relevant DSM to date.

  14. Development of standard test methods for evaluating defibrillation recovery characteristics of disposable ECG electrodes.

    Science.gov (United States)

    Schoenberg, A A; Booth, H E; Lyon, P C

    1979-01-01

    A clinically relevant test for the measurement of defibrillation overload recovery of prefilled disposable ECG electrodes was developed and is proposed for use in an ECG electrode standard under development by AAMI. Defibrillation overload voltages and currents, as well as electrode polarization recovery voltages, were first measured in animal tests on 12 types of electrodes to allow correlation with various bench tests using a capacitor discharge at 10, 200, or 1000 V. Current overloads absorbed by the electrodes under worst conditions in animal tests were in the range of 2 percent of the defibrillation current flowing through the chest. These overloads were absorbed by most Ag-AgCl electrodes without excessive polarization. However, stainless steel, brass, and tin electrodes tended to polarize to levels that would saturate many ECG monitors. A standard bench test using a 200-V 10-muF capacitor was recommended for inclusion in the AAMI standard to determine whether electrodes are acceptable for use during defibrillation.

  15. Use of automated external defibrillators in a Brazilian airline. A 1-year experience

    Directory of Open Access Journals (Sweden)

    Alves Paulo Magalhães

    2001-01-01

    Full Text Available After the incorporation of automated external defibrilators by other airlines and the support of the Brazilian Society of cardiology, Varig Airlines Began the onboard defibrilation program with the initial purpose of equiping wide-body aircrafts frequently used in international flights and that airplanes use in the Rio - São Paulo route. With all fight attendants trained, the automated. External defibrilation devides were incorporated to 34 airplanes of a total pleet of 80 aircrats. The devices were intalled in the bagage compartments secured with velero straps and 2 pairs of electrods, one or which pre-conected to the device to minimize application time. Later, a portable monitor was addres to the ressocitation kit in the long flights. The expansion of the knowledge of the basic life support fundamentors and the correted implantation of the survival chain and of the automated external defibrilators will increase the extense of recovery of cardiorespiratory arrest victins in aircrafts.

  16. Implantable defibrillators improve survival in patients with mildly symptomatic heart failure receiving cardiac resynchronization therapy

    DEFF Research Database (Denmark)

    Gold, Michael R; Daubert, Jean-Claude; Abraham, William T;

    2013-01-01

    Cardiac resynchronization therapy (CRT) decreases mortality, improves functional status, and induces reverse left ventricular remodeling in selected populations with heart failure. These benefits have been noted with both CRT-pacemakers as well as those devices with defibrillator backup (CRT...

  17. Systematic review of validated case definitions for diabetes in ICD-9-coded and ICD-10-coded data in adult populations

    Science.gov (United States)

    Khokhar, Bushra; Jette, Nathalie; Metcalfe, Amy; Cunningham, Ceara Tess; Kaplan, Gilaad G; Butalia, Sonia; Rabi, Doreen

    2016-01-01

    Objectives With steady increases in ‘big data’ and data analytics over the past two decades, administrative health databases have become more accessible and are now used regularly for diabetes surveillance. The objective of this study is to systematically review validated International Classification of Diseases (ICD)-based case definitions for diabetes in the adult population. Setting, participants and outcome measures Electronic databases, MEDLINE and Embase, were searched for validation studies where an administrative case definition (using ICD codes) for diabetes in adults was validated against a reference and statistical measures of the performance reported. Results The search yielded 2895 abstracts, and of the 193 potentially relevant studies, 16 met criteria. Diabetes definition for adults varied by data source, including physician claims (sensitivity ranged from 26.9% to 97%, specificity ranged from 94.3% to 99.4%, positive predictive value (PPV) ranged from 71.4% to 96.2%, negative predictive value (NPV) ranged from 95% to 99.6% and κ ranged from 0.8 to 0.9), hospital discharge data (sensitivity ranged from 59.1% to 92.6%, specificity ranged from 95.5% to 99%, PPV ranged from 62.5% to 96%, NPV ranged from 90.8% to 99% and κ ranged from 0.6 to 0.9) and a combination of both (sensitivity ranged from 57% to 95.6%, specificity ranged from 88% to 98.5%, PPV ranged from 54% to 80%, NPV ranged from 98% to 99.6% and κ ranged from 0.7 to 0.8). Conclusions Overall, administrative health databases are useful for undertaking diabetes surveillance, but an awareness of the variation in performance being affected by case definition is essential. The performance characteristics of these case definitions depend on the variations in the definition of primary diagnosis in ICD-coded discharge data and/or the methodology adopted by the healthcare facility to extract information from patient records. PMID:27496226

  18. Reliability of clinical ICD-10 diagnoses among electroconvulsive therapy patients with chronic affective disorders

    Directory of Open Access Journals (Sweden)

    Klaus Damgaard Jakobsen

    2008-09-01

    Full Text Available Background and Objectives: Diagnostic reliability is of major concern both to clinicians and researchers. The aim has been to investigate the trustworthiness of clinical ICD-10 affective disorder diagnoses for research purpose. Methods: 150 ECT patients with chronic affective disorders were investigated. A standardized schema for basic anamnesis and the Operational Criteria Checklist for Psychotic and Affective Illness (OPCRIT were used. The sensitivity, specificity, positive and negative predictive values of clinical affective disorder ICD-10 diagnoses and the formal agreement between clinical ICD-10, OPCRIT ICD-10 and DSM-IV diagnoses were determined using unweighted κ-statistics. Results: The sensitivity, specificity, positive and negative predictive values of the clinical bipolar diagnoses was 0.55, 0.75, 0.42 and 0.84, respectively. The sensitivity, specificity, positive and negative predictive values of the clinical unipolar diagnoses was 0.79, 0.55, 0.77 and 0.58, respectively. The agreement between clinical ICD-10 and OPCRIT ICD-10 bipolar vs. non-bipolar diagnoses was low, κ = 0.28. The agreement between clinical ICD-10 and OPCRIT ICD-10 unipolar vs. non-unipolar diagnoses was low, κ = 0.35. The agreement between OPCRIT ICD-10 and DSM-IV diagnoses on bipolar vs. non-bipolar disorders was high, κ = 0.91, and the agreement on unipolar vs. non-unipolar disorders was fairly high, κ = 0.78. Conclusions: This study demonstrates that the reliability of clinical ICD-10 diagnoses of affective disorders from chronic subjects with a history of ECT is problematic despite sample homogeneity on basic clinical, demographic and epidemiological parameters.

  19. Optimizing a Drone Network to Deliver Automated External Defibrillators.

    Science.gov (United States)

    Boutilier, Justin J; Brooks, Steven C; Janmohamed, Alyf; Byers, Adam; Buick, Jason E; Zhan, Cathy; Schoellig, Angela P; Cheskes, Sheldon; Morrison, Laurie J; Chan, Timothy C Y

    2017-03-02

    Background -Public access defibrillation programs can improve survival after out-of-hospital cardiac arrest (OHCA), but automated external defibrillators (AEDs) are rarely available for bystander use at the scene. Drones are an emerging technology that can deliver an AED to the scene of an OHCA for bystander use. We hypothesize that a drone network designed with the aid of a mathematical model combining both optimization and queuing can reduce the time to AED arrival. Methods -We applied our model to 53,702 OHCAs that occurred in the eight regions of the Toronto Regional RescuNET between January 1st 2006 and December 31st 2014. Our primary analysis quantified the drone network size required to deliver an AED one, two, or three minutes faster than historical median 911 response times for each region independently. A secondary analysis quantified the reduction in drone resources required if RescuNET was treated as one large coordinated region. Results -The region-specific analysis determined that 81 bases and 100 drones would be required to deliver an AED ahead of median 911 response times by three minutes. In the most urban region, the 90th percentile of the AED arrival time was reduced by 6 minutes and 43 seconds relative to historical 911 response times in the region. In the most rural region, the 90th percentile was reduced by 10 minutes and 34 seconds. A single coordinated drone network across all regions required 39.5% fewer bases and 30.0% fewer drones to achieve similar AED delivery times. Conclusions -An optimized drone network designed with the aid of a novel mathematical model can substantially reduce the AED delivery time to an OHCA event.

  20. Public access defibrillators and fire extinguishers: are comparisons reasonable?

    Science.gov (United States)

    Mell, Howard K; Sayre, Michael R

    2008-01-01

    Sudden cardiac death is a major cause of mortality in the United States of America (Circulation 2008;117:e25-146) with approximately 310000 deaths related to coronary heart disease occurring in emergency departments or in the prehospital environment annually. Several organizations have directed resources toward the treatment of sudden cardiac arrest through a paradigm that has come to be known as the "chain of survival"-prompt activation of emergency response by telephone 911, early bystander cardiopulmonary resuscitation, early defibrillation, and timely advanced cardiac life support (Circulation 1991;83:1832-1847). The ready availability of automated external defibrillators (AEDs) has been advocated as a key component of this chain. Some authors have suggested a "fire extinguisher model" for AED deployment (Circulation 1998;98:2334-2351; Resuscitation 1995;30:151-156; Ann Intern Med 2001;135:990-998). In this model, AEDs are prominently displayed in public places for use by laypersons, much like fire extinguishers. For example, in Chicago's O'Hare Airport, AEDs are placed alongside fire extinguishers in the public concourse (N Engl J Med 2002;347:1242-1247). Advocates of this model suggest that advancing this practice would be a means to widely disbourse life-saving technology that is easy to use. Several experts have questioned this model, suggesting that the cost-effectiveness of distributing AEDs this widely would be prohibitive (BMJ 2002;325:515; Curr Opin Cardiol 2007;22:5-10; BMJ 2003;326:162; Int J Technol Assess Health Care 2007;23:362-367) and may not be more effective than more targeted distribution of AEDs. This literature review will examine the available data on both AEDs and fire extinguishers to determine if these comparisons are reasonable as a means of guiding public policy.

  1. [Recommendations for the treatment of heart failure : What's new?].

    Science.gov (United States)

    Hasenfuß, G; Edelmann, F; Wachter, R

    2013-09-01

    Treatment escalation of chronic systolic heart failure depends on left ventricular function and symptoms of the patients. In symptomatic patients with severely reduced left ventricular function (ejection fraction ≤ 30 %), the following therapeutic approaches are recommended: (1) angiotensin-converting enzyme (ACE) inhibitors (angiotensin receptor blocker in case of ACE inhibitor intolerance); (2) β-blockers; (3) mineralocorticoid receptor antagonists; (4) diuretics in case of signs and symptoms of congestion; (5) digitalis, in particular in patients with atrial fibrillation; (6) ivabradine in patients with sinus rhythm and a heart rate ≥ 75/min; (7) an implantable cardioverter defibrillator (ICD); (8) in case of left bundle branch block or wide QRS complex, cardiac resynchronization therapy (CRT; in most cases in combination with an implantable cardioverter defibrillator); (9) intravenous administration of iron in case of iron deficiency; (10) exercise training should be strongly recommended in patients with stable heart failure.

  2. 双硫仑样反应ICD-10编码探讨%Discussion of Disulfiram Like Reaction of ICD-10 Code

    Institute of Scientific and Technical Information of China (English)

    江俊

    2015-01-01

    Objective To summary the key points of coding for disulfiram-like reaction in ICD-10. Methods On the base of introducing pharmacological ef ect of disulfirm and pathogenesis of disulfiram-like reaction,the ways of Coding for Disulfiram-like Reaction in ICD-10 were analyzed. Results The coding are:disulfiram poisoning T50.6,ethanol combined with antibacterial agents or disulfiram T52.8、T65.8.Conclusion It was very important for coding clerks to master the ICD-10 searching methods,learn relevant knowledge about the disease,and careful y read medical records,so as to manage accurately ICD-10 ecoding of disulfiram-like reaction.%目的总结双硫仑样反应ICD-10编码的要点。方法介绍双硫仑的药理作用及双硫仑样反应的发病机制,分析不同原因引起的双硫仑样反应ICD-10编码的方法。结果双硫仑中毒T50.6,抗生素或双硫仑与酒精联用T52.8。结论掌握ICD-10的查找方法,理解双硫仑样反应相关知识,仔细阅读分析病案,是正确编码双硫仑样反应的关键。

  3. The Utility and Challenges of Using ICD Codes in Child Maltreatment Research: A Review of Existing Literature

    Science.gov (United States)

    Scott, Debbie; Tonmyr, Lil; Fraser, Jenny; Walker, Sue; McKenzie, Kirsten

    2009-01-01

    Objective: The objectives of this article are to explore the extent to which the International Statistical Classification of Diseases and Related Health Problems (ICD) has been used in child abuse research, to describe how the ICD system has been applied, and to assess factors affecting the reliability of ICD coded data in child abuse research.…

  4. Obsessive-compulsive disorder for ICD-11: proposed changes to the diagnostic guidelines and specifiers

    Directory of Open Access Journals (Sweden)

    Helen Blair Simpson

    2014-01-01

    Full Text Available Since the approval of the ICD-10 by the World Health Organization (WHO in 1990, global research on obsessive-compulsive disorder (OCD has expanded dramatically. This article evaluates what changes may be needed to enhance the scientific validity, clinical utility, and global applicability of OCD diagnostic guidelines in preparation for ICD-11. Existing diagnostic guidelines for OCD were compared. Key issues pertaining to clinical description, differential diagnosis, and specifiers were identified and critically reviewed on the basis of the current literature. Specific modifications to ICD guidelines are recommended, including: clarifying the definition of obsessions (i.e., that obsessions can be thoughts, images, or impulses/urges and compulsions (i.e., clarifying that these can be behaviors or mental acts and not calling these “stereotyped”; stating that compulsions are often associated with obsessions; and removing the ICD-10 duration requirement of at least 2 weeks. In addition, a diagnosis of OCD should no longer be excluded if comorbid with Tourette syndrome, schizophrenia, or depressive disorders. Moreover, the ICD-10 specifiers (i.e., predominantly obsessional thoughts, compulsive acts, or mixed should be replaced with a specifier for insight. Based on new research, modifications to the ICD-10 diagnostic guidelines for OCD are recommended for ICD-11.

  5. The impact of proposed changes to ICD-11 on estimates of PTSD prevalence and comorbidity.

    Science.gov (United States)

    Wisco, Blair E; Miller, Mark W; Wolf, Erika J; Kilpatrick, Dean; Resnick, Heidi S; Badour, Christal L; Marx, Brian P; Keane, Terence M; Rosen, Raymond C; Friedman, Matthew J

    2016-06-30

    The World Health Organization's posttraumatic stress disorder (PTSD) work group has published a proposal for the forthcoming edition of the International Classification of Diseases (ICD-11) that would yield a very different diagnosis relative to DSM-5. This study examined the impact of the proposed ICD-11 changes on PTSD prevalence relative to the ICD-10 and DSM-5 definitions and also evaluated the extent to which these changes would accomplish the stated aim of reducing the comorbidity associated with PTSD. Diagnostic prevalence estimates were compared using a U.S. national community sample and two U.S. Department of Veterans Affairs clinical samples. The ICD-11 definition yielded prevalence estimates 10-30% lower than DSM-5 and 25% and 50% lower than ICD-10 with no reduction in the prevalence of common comorbidities. Findings suggest that by constraining the diagnosis to a narrower set of symptoms, the proposed ICD-11 criteria set would substantially reduce the number of individuals with the disorder. These findings raise doubt about the extent to which the ICD-11 proposal would achieve the aim of reducing comorbidity associated with PTSD and highlight the public health and policy implications of such a redefinition.

  6. Intracellular fragment of NLRR3 (NLRR3-ICD) stimulates ATRA-dependent neuroblastoma differentiation

    Energy Technology Data Exchange (ETDEWEB)

    Akter, Jesmin [Laboratory of Innovative Cancer Therapeutics, Chiba Cancer Center Research Institute, Chiba 260-8717 (Japan); Takatori, Atsushi, E-mail: atakatori@chiba-cc.jp [Laboratory of Cancer Genetics, Chiba Cancer Center Research Institute, Chiba 260-8717 (Japan); Islam, Md. Sazzadul [Laboratory of Innovative Cancer Therapeutics, Chiba Cancer Center Research Institute, Chiba 260-8717 (Japan); Nakazawa, Atsuko [Department of Pathology, National Center for Child Health and Development, Tokyo (Japan); Ozaki, Toshinori, E-mail: tozaki@chiba-cc.jp [Laboratory of DNA Damage Signaling, Chiba Cancer Center Research Institute, Chiba 260-8717 (Japan); Nagase, Hiroki [Laboratory of Cancer Genetics, Chiba Cancer Center Research Institute, Chiba 260-8717 (Japan); Nakagawara, Akira [Saga Medical Centre, 840-8571 (Japan)

    2014-10-10

    Highlights: • NLRR3 is a membrane protein highly expressed in favorable neuroblastoma. • NLRR3-ICD was produced through proteolytic processing by secretases. • NLRR3-ICD was induced to be translocated into cell nucleus following ATRA exposure. • NLRR3-ICD plays a pivotal role in ATRA-mediated neuroblastoma differentiation. - Abstract: We have previously identified neuronal leucine-rich repeat protein-3 (NLRR3) gene which is preferentially expressed in favorable human neuroblastomas as compared with unfavorable ones. In this study, we have found for the first time that NLRR3 is proteolytically processed by secretases and its intracellular domain (NLRR3-ICD) is then released to translocate into cell nucleus during ATRA-mediated neuroblastoma differentiation. According to our present observations, NLRR3-ICD was induced to accumulate in cell nucleus of neuroblastoma SH-SY5Y cells following ATRA treatment. Since the proteolytic cleavage of NLRR3 was blocked by α- or γ-secretase inhibitor, it is likely that NLRR3-ICD is produced through the secretase-mediated processing of NLRR3. Intriguingly, forced expression of NLRR3-ICD in neuroblastoma SK-N-BE cells significantly suppressed their proliferation as examined by a live-cell imaging system and colony formation assay. Similar results were also obtained in neuroblastoma TGW cells. Furthermore, overexpression of NLRR3-ICD stimulated ATRA-dependent neurite elongation in SK-N-BE cells. Together, our present results strongly suggest that NLRR3-ICD produced by the secretase-mediated proteolytic processing of NLRR3 plays a crucial role in ATRA-mediated neuronal differentiation, and provide a clue to develop a novel therapeutic strategy against aggressive neuroblastomas.

  7. Evaluation of inpatient clinical documentation readiness for ICD-10-CM.

    Science.gov (United States)

    DeAlmeida, Dilhari R; Watzlaf, Valerie J; Anania-Firouzan, Patti; Salguero, Otto; Rubinstein, Elaine; Abdelhak, Mervat; Parmanto, Bambang

    2014-01-01

    This research study examined the gaps in documentation that occur when coding in ICD-10-CM. More than 4,000 diagnoses from all chapters were coded from 656 electronic documents obtained from a large integrated healthcare facility at the time the study was conducted (2012). After the documents were coded, areas for documentation improvement were identified for chapters that resulted in deficiencies in documentation, and a quick reference guide was developed. The overall absent documentation percentage was 15.4 percent. The 10 chapters with the highest percentage of absent documentation were chapter 7 (Diseases of Eye and Adnexa), with 67.65 percent (p Diseases of Ear and Mastoid Process), with 63.64 percent (p Diseases of the Musculoskeletal System and Connective Tissue), with 46.05 percent (p Diseases of the Genitourinary System), with 40.29 percent (p Diseases of Respiratory System), with 35.52 percent (p Parasitic Diseases), with 32.88 percent (p Diseases of the Skin and Subcutaneous Tissue), with 32.35 percent (p Diseases), with 14.58 percent (p < .001); and chapter 17 (Congenital Malformations, Deformations, and Chromosomal Abnormalities), with 12.50 percent. We addressed the deficient areas in the quick reference guide developed for clinicians and technology vendors. Having complete and accurate documentation would benefit both the clinician and the patient in providing the highest quality of care.

  8. Sikkerhed af magnetisk resonans-skanning hos patienter med pacemaker og implanterbar defibrillator

    DEFF Research Database (Denmark)

    Al-Sabagh, Kifah Hekmat; Christensen, Britta Ege; Thøgersen, Anna Margrethe;

    2010-01-01

    INTRODUCTION: The presence of a cardiac implantable device is ICD considered an absolute contraindication to magnetic resonance imaging (MRI). The purpose of this study was to evaluate the safety of performing MRI in patients with cardiac pacemakers and ICDs that had a compelling clinical need...

  9. Discussion on Bone Cement Implantation Syndrome ICD-10 Coding%骨水泥植入综合征ICD-10编码的探讨

    Institute of Scientific and Technical Information of China (English)

    刘颖

    2016-01-01

    Clinical syndrome is a variety of clinical manifestations characterized diagnosis name caused by different causes of unknown etiology. As an independent disease diagnosis, it brings certain difficulty of ICD coding. In this paper, we take bone cement implantation syndrome for example. We had not been found the corresponding code after looking for the main word "Syndrome", "disease" and "disorder" in ICD-10 book Ⅲ index table. Through referring to the relevant medical information, and timely communicating with the clinician, we had the further understanding for its etiology, pathogenesis, clinical manifestations, etc, stripping external representation and dig the nature of the disease, find out the most main pathogenesis of bone cement implantation syndrome, follow the ICD coding rules, eventually give correct classification of diseases T88.7. This article discussed ICD-10 code process of bone cement implantation syndrome, in order to communicate with peers, and improve the quality of diagnostic codes.%临床综合征是以病因不明或不同病因并存而引起的多种临床表现为特征的诊断名称,作为非独立的疾病诊断,给 ICD 编码的查找工作带来一定难度.本文以骨水泥植入综合征为例,在 ICD-10 卷三索引表中对主导词"综合征"、"病"、"疾患"等查询,均未查到与之对应的编码.通过查阅相关医学资料,并及时与临床医师沟通,对其病因、发病机制、临床表现等方面有了进一步了解,剥去外在表象探索疾病的本质,找出引起骨水泥植入综合征最主要的发病机制,遵循 ICD 编码规则,最终给予正确疾病分类 T88.7.通过对骨水泥植入综合征的 ICD-10 编码过程加以阐述,以期与同行交流,提高疾病诊断编码质量.

  10. Epidemiology, course and outcome of acute polymorphic psychotic disorder: implications for ICD-11

    DEFF Research Database (Denmark)

    Castagnini, Augusto; Foldager, Leslie

    2014-01-01

    Background: The proposed revision of the ICD-10 category of ‘acute and transient psychotic disorders' (ATPDs), subsuming polymorphic, schizophrenic or predominantly delusional syndromes, would restrict their classification to acute polymorphic psychotic disorder, reminiscent of the clinical conce...

  11. Changes needed in the classification of anxiety disorders in childhood: Options for ICD-11

    Directory of Open Access Journals (Sweden)

    Stanković Miodrag

    2015-01-01

    Full Text Available Considering the intensive preparation of the 11th revision of the International Classification of Diseases (ICD-11, we discussed the justification of the existing classification of emotional disorders with onset specific to childhood. This paper presents the citations from the ICD-10 (F93 block and the authors’ comments as a critical review of the justification of further existence of emotional disorders with onset specific to childhood as a separate block in ICD-11 classification. We concluded that the block F93 is insufficiently defined and should be completely changed or removed from the ICD-11 classification. Additionally, the specificities of the clinical picture of anxiety disorders in children should be adequately described within the future category of anxiety and phobic disorders by giving an explicit set of instructions for identifying clinical manifestations which vary by age.

  12. Time-resolved study of ICD in Ne dimers using FEL radiation

    Energy Technology Data Exchange (ETDEWEB)

    Schnorr, K., E-mail: kirsten.schnorr@mpi-hd.mpg.de [Max-Planck-Institut für Kernphysik, Saupfercheckweg 1, 69117 Heidelberg (Germany); Senftleben, A. [Universität Kassel, 34132 Kassel (Germany); Schmid, G.; Augustin, S.; Kurka, M. [Max-Planck-Institut für Kernphysik, Saupfercheckweg 1, 69117 Heidelberg (Germany); Rudenko, A. [J.R. Macdonald Laboratory, Kansas State University, Manhattan, KS 66506 (United States); Foucar, L. [Max-Planck-Institut für medizinische Forschung, 69120 Heidelberg (Germany); Broska, A.; Meyer, K. [Max-Planck-Institut für Kernphysik, Saupfercheckweg 1, 69117 Heidelberg (Germany); Anielski, D.; Boll, R. [Deutsches Elektronen-Synchrotron, 22607 Hamburg (Germany); Rolles, D. [J.R. Macdonald Laboratory, Kansas State University, Manhattan, KS 66506 (United States); Kübel, M.; Kling, M.F. [Physics Department, Ludwig-Maximilians-Universität München, 85748 Garching (Germany); Jiang, Y.H. [Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210 (China); Mondal, S.; Tachibana, T.; Ueda, K. [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, Sendai 980-8577 (Japan); Marchenko, T.; Simon, M. [Laboratoire de Chimie Physique-Matière et Rayonnement, UPMC and CNRS, 75231 Paris (France); and others

    2015-10-15

    Interatomic Coulombic Decay (ICD) is a relaxation phenomenon, which takes place in weakly bound atomic and molecular systems, typically within a few to hundreds of femtoseconds depending on the system and the particular decay mechanism. The creation of ICD-active states requires the production of highly excited systems, usually populated by innershell ionization or excitation. To this end, XUV and X-ray radiation from synchrotrons was conventionally applied for the majority of experiments due to the desired state-selective ionization of certain sub-shells. The advent of Free-Electron Lasers (FELs) has enabled an entirely new class of experiments, which finally allow to trace ICD directly in the time domain due to the femtosecond pulse duration. Within this paper, the first time-resolved ICD measurement using an XUV-pump–XUV-probe scheme will be discussed in detail. The experiment was performed on neon dimers and ICD was triggered by removing a 2s electron from one of the neon atoms using a 58 eV pulse from the FEL in Hamburg (FLASH). The onset of ICD was probed with a delayed copy of the trigger pulse that further ionized one of the two Ne{sup +} ions emerging after ICD. Thus, the delay-dependent yield of coincident Ne{sup +} + Ne{sup 2+} ion pairs contains the lifetime of the 2s-innershell vacancy decaying via ICD. The result of 150 fs ± 50 fs is in good agreement with theory but only for those calculations that explicitly take nuclear motion into account.

  13. Nuclear Ep-ICD expression is a predictor of poor prognosis in "low risk" prostate adenocarcinomas.

    Directory of Open Access Journals (Sweden)

    Jasmeet Assi

    Full Text Available Molecular markers for predicting prostate cancer (PCa that would have poor prognosis are urgently needed for a more personalized treatment for patients. Regulated intramembrane proteolysis of Epithelial cell adhesion molecule results in shedding of the extracellular domain (EpEx and release of its intracellular domain (Ep-ICD which triggers oncogenic signaling and might correlate to tumor aggressiveness. This study aimed to explore the potential of Ep-ICD and EpEx to identify PCa that have poor prognosis.Immunohistochemical analysis of Ep-ICD and EpEx was carried out in normal prostate tissues (n = 100, benign prostate hyperplasia (BPH, n = 83, and prostate cancer (n = 249 using domain specific antibodies. The expression of Ep-ICD and EpEx was correlated with clinico- pathological parameters and disease free survival (DFS.Reduced expression of nuclear Ep-ICD and membrane EpEx was observed in PCa in comparison with BPH and normal prostate tissues (p = 0.006, p < 0.001 respectively. For patients who had PCa with Gleason Score less than 7, preserved nuclear Ep-ICD emerged as the most significant marker in multivariate analysis for prolonged DFS, where these patients did not have recurrence during follow up of up to 12 years (p = 0.001.Reduced expression of nuclear Ep-ICD was associated with shorter disease free survival in patients with a Gleason Score less than 7 and may be useful in identifying patients likely to have aggressive tumors with poor prognosis. Furthermore, nuclear Ep-ICD can differentiate between normal and prostate cancer tissues for ambiguous cases.

  14. Effect of Metoprolol Versus Carvedilol on Outcomes in MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy)

    DEFF Research Database (Denmark)

    Ruwald, Martin H; Ruwald, Anne-Christine H; Jøns, Christian;

    2013-01-01

    This study sought to compare the effects of metoprolol and carvedilol in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy) study.......This study sought to compare the effects of metoprolol and carvedilol in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy) study....

  15. Validity of ICD-9-CM codes for the identification of complications related to central venous catheterization.

    Science.gov (United States)

    Tukey, Melissa H; Borzecki, Ann M; Wiener, Renda Soylemez

    2015-01-01

    Two complications of central venous catheterization (CVC), iatrogenic pneumothorax and central line-associated bloodstream infection (CLABSI), have dedicated International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) codes. Despite increasing use of ICD-9-CM codes for research and pay-for-performance purposes, their validity for detecting complications of CVC has not been established. Complications of CVCs placed between July 2010 and December 2011 were identified by ICD-9-CM codes in discharge records from a single hospital and compared with those revealed by medical record abstraction. The ICD-9-CM code for iatrogenic pneumothorax had a sensitivity of 66.7%, specificity of 100%, positive predictive value (PPV) of 100%, and negative predictive value (NPV) of 99.5%. The ICD-9-CM codes for CLABSI had a sensitivity of 33.3%, specificity of 99.0%, PPV of 28.6%, and NPV of 99.2%. The low sensitivity and variable PPV of ICD-9-CM codes for detection of complications of CVC raise concerns about their use for research or pay-for-performance purposes.

  16. Intracellular fragment of NLRR3 (NLRR3-ICD) stimulates ATRA-dependent neuroblastoma differentiation.

    Science.gov (United States)

    Akter, Jesmin; Takatori, Atsushi; Islam, Md Sazzadul; Nakazawa, Atsuko; Ozaki, Toshinori; Nagase, Hiroki; Nakagawara, Akira

    2014-10-10

    We have previously identified neuronal leucine-rich repeat protein-3 (NLRR3) gene which is preferentially expressed in favorable human neuroblastomas as compared with unfavorable ones. In this study, we have found for the first time that NLRR3 is proteolytically processed by secretases and its intracellular domain (NLRR3-ICD) is then released to translocate into cell nucleus during ATRA-mediated neuroblastoma differentiation. According to our present observations, NLRR3-ICD was induced to accumulate in cell nucleus of neuroblastoma SH-SY5Y cells following ATRA treatment. Since the proteolytic cleavage of NLRR3 was blocked by α- or γ-secretase inhibitor, it is likely that NLRR3-ICD is produced through the secretase-mediated processing of NLRR3. Intriguingly, forced expression of NLRR3-ICD in neuroblastoma SK-N-BE cells significantly suppressed their proliferation as examined by a live-cell imaging system and colony formation assay. Similar results were also obtained in neuroblastoma TGW cells. Furthermore, overexpression of NLRR3-ICD stimulated ATRA-dependent neurite elongation in SK-N-BE cells. Together, our present results strongly suggest that NLRR3-ICD produced by the secretase-mediated proteolytic processing of NLRR3 plays a crucial role in ATRA-mediated neuronal differentiation, and provide a clue to develop a novel therapeutic strategy against aggressive neuroblastomas.

  17. Proposed ICD-10-CM Surveillance Case Definitions for Injury Hospitalizations and Emergency Department Visits.

    Science.gov (United States)

    Hedegaard, Holly B; Johnson, Renee L; Ballesteros, Michael F

    2017-01-01

    This report describes a collaboration between the National Center for Health Statistics and the National Center for Injury Prevention and Control to develop proposed surveillance case definitions for injury hospitalizations and emergency department (ED) visits for use with administrative data sets coded using the International Classification of Diseases, Tenth Revision, Clinical Modification (ICD-10-CM). The proposed ICD-10-CM surveillance case definitions were developed by applying General Equivalence Mappings to the International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) definitions. As with the ICD-9-CM definitions, there are slight differences between the proposed ICD-10-CM surveillance case definition for injury hospitalizations and the one for ED visits. The inclusion criteria for an injury hospitalization requires a case to have a principal diagnosis of one of the included nature-of-injury (injury diagnosis) codes. The inclusion criteria for an injury ED visit requires the case to have either a principal diagnosis of one of the included nature-of-injury codes or the presence of selected external-cause codes. The ICD-10-CM nature-of-injury and external-cause codes included in the proposed definitions are presented and caveats for use of the proposed definitions are described.

  18. Virtual electrodes around anatomical structures and their roles in defibrillation

    Science.gov (United States)

    Vigmond, Edward; Bishop, Martin

    2017-01-01

    Background Virtual electrodes from structural/conductivity heterogeneities are known to elicit wavefront propagation, upon field-stimulation, and are thought to be important for defibrillation. In this work we investigate how the constitutive and geometrical parameters associated with such anatomical heterogeneities, represented by endo/epicardial surfaces and intramural surfaces in the form of blood-vessels, affect the virtual electrode patterns produced. Methods and results The steady-state bidomain model is used to obtain, using analytical and numerical methods, the virtual electrode patterns created around idealized endocardial trabeculations and blood-vessels. The virtual electrode pattern around blood-vessels is shown to be composed of two dominant effects; current traversing the vessel surface and conductivity heterogeneity from the fibre-architecture. The relative magnitudes of these two effects explain the swapping of the virtual electrode polarity observed, as a function of the vessel radius, and aid in the understanding of the virtual electrode patterns predicted by numerical bidomain modelling. The relatively high conductivity of blood, compared to myocardium, is shown to cause stronger depolarizations in the endocardial trabeculae grooves than the protrusions. Conclusions The results provide additional quantitative understanding of the virtual electrodes produced by small-scale ventricular anatomy, and highlight the importance of faithfully representing the physiology and the physics in the context of computational modelling of field stimulation. PMID:28253365

  19. A comparative study on nutritional status of under 6 years children in i.c.d.s. And non i.c.d.s. Tribal areas of uttar pradesh

    Directory of Open Access Journals (Sweden)

    Shiv prakash

    2004-06-01

    Full Text Available Objectives :To find out the nutritional status of children under six year. .To determine the level of difference in nutritional status of Children under six years in I.C.D.S. and Non I.C.D.S. tribal areas.To assess the impact of I.C.D.S. scheme on nutritional status of children below six years.Study Design : Cross Sectional StudyParticipants : Under six years children.Sample Size : 1536 children of Nighasan block (I.C.D.S. block and 1471 of Ramia Behar block (Non I.C.D.S. block. Key Words : Nutritional status, I.C.D.S., height - weight index, Service impact.Results : All the value for height & weight in both groups were lower as compared to the I.C.M.R. standards. All children in I.C.D.S. group were below the normal weight - height index (i.e. > 0.15 while in Non I.C.D.S. group were below normal wt.-ht. index in all age group except 6 -<24 months male & 3 - < 9 months female. Overall prevalence of P.E.M. in I.C.D.S. group was 90.36& while it was 86.85% in Non I.C.D.S. group. The difference was significant.  

  20. [Training program on cardiopulmonary resuscitation with the use of automated external defibrillator in a university].

    Science.gov (United States)

    Boaventura, Ana Paula; Miyadahira, Ana Maria Kazue

    2012-03-01

    Early defibrillation in cardiopulmonary resuscitation (CPR) receives increasing emphasis on its priority and rapidity. This is an experience report about the implementation of a training program in CPR using a defibrillator in a private university. The training program in basic CPR maneuvers was based on global guidelines, including a theorical course with practical demonstration of CPR maneuvers with the defibrillator, individual practical training and theoretical and practical assessments. About the performance of students in the practical assessment the mean scores obtained by students in the first stage of the course was 26.4 points, while in the second stage the mean was 252.8 points, in the theoretical assessment the mean in the first stage was 3.06 points and in the second 9.0 points. The implementation of programs like this contribute to the effective acquisition of knowledge (theory) and skill (pratice) for the care of CPR victims.

  1. COPE-ICD: a randomised clinical trial studying the effects and meaning of a comprehensive rehabilitation programme for ICD recipients -design, intervention and population

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Svendsen, Jesper H; Zwisler, Ann-Dorthe;

    2011-01-01

    Growing evidence exists that living with an ICD can lead to fear and avoidance behaviour including the avoidance of physical activity. It has been suggested that psychological stress can increase the risk of shock and predict death. Small studies have indicated a beneficial effect arising from ex...

  2. COPE-ICD: a randomised clinical trial studying the effects and meaning of a comprehensive rehabilitation programme for ICD recipients -design, intervention and population

    DEFF Research Database (Denmark)

    Berg, Selina K; Svendsen, Jesper H; Zwisler, Ann-Dorthe

    2011-01-01

    Growing evidence exists that living with an ICD can lead to fear and avoidance behaviour including the avoidance of physical activity. It has been suggested that psychological stress can increase the risk of shock and predict death. Small studies have indicated a beneficial effect arising from...... exercise training and psychological intervention, therefore a large-scale rehabilitation programme was set up....

  3. Line of Thinking in ICD-10 Coding of Abdominal Compartment Syndrome%腹腔间隔室综合征的ICD-10编码探讨

    Institute of Scientific and Technical Information of China (English)

    伍英; 彭志刚; 陈红; 黄俐明

    2015-01-01

    本文从概念、定义和ICD1-10编码规则入手,对室隔综合征的临床分型(创伤性骨筋膜室综合征、青光眼、颅内高压综合征、心包填塞、腹腔间隔室综合征)和ICD-10分类之间关系进行了分析对比,提出腹腔间隔室综合征也应与其他室隔综合征同理,编码到消化系统疾病相应章节,即K92.8亚目下。%Based on the concepts, definitions, and coding rules of ICD-10, our studying analyzed and compared the relationship between clinical types and ICD-10 clas ifications of abdominal compartment syndrome, and discus ed the thinking line in ICD-10 Coding of abdominal compartment syndrome . Compartment syndrome divided into the fol owing groups: abdominal compartment syndrome, intracompartment syndrome,intracranial hypertension syndrome, glaucoma, cardiac tamponade. Intracompartment syndrome should be coded to T79.6, intracranial hypertension syndrome:G93.2. glaucoma:H40.0-H40.9,H42.0-H42.8. cardiac tamponade:131.9, so abdominal compartment syndrome should be coded to K92.8 based its interestinal system .

  4. Complex Tricuspid Valve Repair in Patients With Pacer Defibrillator-Related Tricuspid Regurgitation.

    Science.gov (United States)

    Raman, Jaishankar; Sugeng, Lissa; Lai, David T M; Jeevanandam, Valluvan

    2016-04-01

    Tricuspid valve regurgitation in patients with heart failure or in those undergoing complex cardiac operations is associated with increased morbidity and mortality. We report our results with a technique of repairing the tricuspid valves while retaining the pacer defibrillator lead. Patients had tricuspid valve repairs that included repositioning of the pacer defibrillator lead, approximation of septal and inferior/posterior leaflets in a modified cleft repair, and implantation of a tricuspid annuloplasty ring. This procedure was performed in more than 42 patients with good success.

  5. Use and benefits of public access defibrillation in a nation-wide network

    DEFF Research Database (Denmark)

    Nielsen, Anne Møller; Folke, Fredrik; Lippert, Freddy Knudsen

    2013-01-01

    BACKGROUND: Automated External Defibrillators (AEDs) are known to increase survival after out-of-hospital cardiac arrest (OHCA). The aim of this study was to examine the use and benefit of public-access defibrillation (PAD) in a nation-wide network. We primarily sought to assess survival at 1 month...... to exercise (42% vs. 0%), and with improved 30-day survival (69% vs. 15%, p=0.001). Among those presenting with a shockable rhythm, 20 (65%) had Return of Spontaneous Circulation upon arrival of EMS and 8 (26%) were conscious, which emphasizes the diagnostic value of ECG downloads from AEDs. Survival could...

  6. Administrative simplification: change to the compliance date for the International Classification of Diseases, 10th Revision (ICD-10-CM and ICD-10-PCS) medical data code sets. Final rule.

    Science.gov (United States)

    2014-08-04

    This final rule implements section 212 of the Protecting Access to Medicare Act of 2014 by changing the compliance date for the International Classification of Diseases, 10th Revision, Clinical Modification (ICD-10-CM) for diagnosis coding, including the Official ICD-10-CM Guidelines for Coding and Reporting, and the International Classification of Diseases, 10th Revision, Procedure Coding System (ICD-10-PCS) for inpatient hospital procedure coding, including the Official ICD-10-PCS Guidelines for Coding and Reporting, from October 1, 2014 to October 1, 2015. It also requires the continued use of the International Classification of Diseases, 9th Revision, Clinical Modification, Volumes 1 and 2 (diagnoses), and 3 (procedures) (ICD-9-CM), including the Official ICD-9-CM Guidelines for Coding and Reporting, through September 30, 2015.

  7. Dominant Suppression of β1 Integrin by Ectopic CD98-ICD Inhibits Hepatocellular Carcinoma Progression

    Directory of Open Access Journals (Sweden)

    Bo Wu

    2016-11-01

    Full Text Available Hepatocellular carcinoma (HCC is currently the third most common cause of cancer-related death in the Asia-Pacific region. Our previous work showed that knockdown of CD98 significantly inhibits malignant HCC cell phenotypes in vitro and in vivo. The level of CD98 in the membrane is tightly regulated to mediate complex processes associated with cell–cell communication and intracellular signaling. In addition, the intracellular domain of CD98 (CD98-ICD seems to be of vital importance for recycling CD98 to the membrane after it is endocytosed. The intracellular and transmembrane domains of CD98 associate with β-integrins (primarily β1 but also β3, and this association is essential for CD98 mediation of integrin-like signaling and complements dominant suppression of β1-integrin. We speculated that isolated CD98-ICD would similarly suppress β1-integrin activation and inhibit the malignant behaviors of cancer cells. In particular, the exact role of CD98-ICD has not been studied independently in HCC. In this study, we found that ectopic expression of CD98-ICD inhibited the malignant phenotypes of HCC cells, and the mechanism possibly involves β1-integrin suppression. Moreover, the expression levels of CD98, β1-integrin-A (the activated form of β1-integrin and Ki-67 were significantly increased in HCC tissues relative to those of normal liver tissues. Therefore, our preliminary study indicates that ectopic CD98-ICD has an inhibitory role in the malignant development of HCC, and shows that CD98-ICD acts as a dominant negative mutant of CD98 that attenuates β1-integrin activation. CD98-ICD may emerge as a promising candidate for antitumor treatment.

  8. Out-of-hospital cardiac arrest and placement of automated external defibrillators in the community

    DEFF Research Database (Denmark)

    Folke, Fredrik

    2010-01-01

    INDLEDNING Chancen for at overleve et hjertestop udenfor hospital er i de første minutter efter kollaps afhængig af hjælpen fra nærmeste tilstedeværende. Dette har faciliteret strategier for placering af automatiske eksterne defibrillatorer (AED) i det offentlige rum og muliggjort hurtig defibril...

  9. Data management in automated external defibrillators: a call for a standardised solution

    DEFF Research Database (Denmark)

    Nielsen, Anne Møller; Rasmussen, L S

    2011-01-01

    The ECG data stored in automated external defibrillators (AEDs) may be valuable for establishing a final diagnosis and deciding further diagnostics and treatment. Different data management systems are used and this may create significant problems for data storage and access for physicians treatin...

  10. Overcoming Spatial and Temporal Barriers to Public Access Defibrillators Via Optimization

    NARCIS (Netherlands)

    Sun, Christopher L.F.; Demirtas, Derya; Brooks, Steven C.; Morrison, Laurie J.; Chan, Timothy C.Y.

    2016-01-01

    Background Immediate access to an automated external defibrillator (AED) increases the chance of survival for out-of-hospital cardiac arrest (OHCA). Current deployment usually considers spatial AED access, assuming AEDs are available 24 h a day. Objectives The goal of this study was to develop an o

  11. Comparison of the effects of removal of chest hair with not doing so before external defibrillation on transthoracic impedance.

    Science.gov (United States)

    Sado, Daniel M; Deakin, Charles D; Petley, Graham W; Clewlow, Frank

    2004-01-01

    Chest hair contributes significantly to transthoracic impedance (TTI) during defibrillation. The magnitude of this effect has not been established using external paddles. We compared TTI in 40 men before elective cardiac surgery, and before and after shaving their chests. Chest hair causes a significant increase in TTI during external defibrillation, the magnitude of the effect being related to both the quantity of hair and force applied to the defibrillation paddles. When the chests of nonhirsute patients were shaved, a decrease in TTI occurred, which was probably related to the creation of low-impedance pathways through skin abrasions.

  12. Tourette and tic disorders in ICD-11: standing at the diagnostic crossroads.

    Science.gov (United States)

    Woods, Douglas W; Thomsen, Per H

    2014-01-01

    This article reflects discussion by the WHO ICD-11 Working Group on the Classification of Obsessive-Compulsive and Related Disorders. After reviewing the historical classification of tic disorders, this article discusses their placement in ICD-11. Existing problems with diagnostic labels and criteria, appropriate placement of the tic disorders category within the ICD-11 system, and pragmatic factors affecting classification are reviewed. The article ends with recommendations to (a) maintain consistency with the DSM-5 diagnostic labels for tic disorders, (b) add a minimum duration guideline for a provisional tic disorder diagnosis, (c) remove the multiple motor tic guideline for the diagnosis of Tourette disorder, and (d) co-parent the tic disorder diagnoses in the disorders of the nervous system and the mental and behavioral disorders categories, with secondary co-parenting in the obsessive-compulsive and related disorders and neurodevelopmental disorders sections.

  13. Obsessive compulsive and related disorders: comparing DSM-5 and ICD-11.

    Science.gov (United States)

    Marras, Anna; Fineberg, Naomi; Pallanti, Stefano

    2016-08-01

    Obsessive-compulsive disorder (OCD) has been recognized as mainly characterized by compulsivity rather than anxiety and, therefore, was removed from the anxiety disorders chapter and given its own in both the American Psychiatric Association (APA) Diagnostic and Statistical Manual of Mental Disorders (DSM-5) and the Beta Draft Version of the 11th revision of the World Health Organization (WHO) International Classification of Diseases (ICD-11). This revised clustering is based on increasing evidence of common affected neurocircuits between disorders, differently from previous classification systems based on interrater agreement. In this article, we focus on the classification of obsessive-compulsive and related disorders (OCRDs), examining the differences in approach adopted by these 2 nosological systems, with particular attention to the proposed changes in the forthcoming ICD-11. At this stage, notable differences in the ICD classification are emerging from the previous revision, apparently converging toward a reformulation of OCRDs that is closer to the DSM-5.

  14. Migration to the ICD-10 coding system: A primer for spine surgeons (Part 1

    Directory of Open Access Journals (Sweden)

    Gazanfar Rahmathulla

    2014-01-01

    Full Text Available Background: On 1 October 2015, a new federally mandated system goes into effect requiring the replacement of the International Classification of Disease-version 9-Clinical Modification (ICD-9-CM with ICD-10-CM. These codes are required to be used for reimbursement and to substantiate medical necessity. ICD-10 is composite with as many as 141,000 codes, an increase of 712% when compared to ICD-9. Methods: Execution of the ICD-10 system will require significant changes in the clinical administrative and hospital-based practices. Through the transition, diminished productivity and practice revenue can be anticipated, the impacts of which the spine surgeon can minimizeby appropriate education and planning. Results: The advantages of the new system include increased clarity and more accurate definitions reflecting patient condition, information relevant to ambulatory and managed care encounters, expanded injury codes, laterality, specificity, precise data for safety and compliance reporting, data mining for research, and finally, enabling pay-for-performance programs. The disadvantages include the cost per physician, training administrative staff, revenue loss during the learning curve, confusion, the need to upgrade hardware along with software, and overall expense to the healthcare system. Conclusions: With the deadline rapidly approaching, gaps in implementation result in delayed billing, delayed or diminished reimbursements, and absence of quality and outcomes data. It is thereby essential for spine surgeons to understand their role in transitioning to this new environment. Part I of this article discusses the background, coding changes, and costs as well as reviews the salient features of ICD-10 in spine surgery

  15. COPE-ICD: A randomised clinical trial studying the effects and meaning of a comprehensive rehabilitation programme for ICD recipients -design, intervention and population

    Directory of Open Access Journals (Sweden)

    Pedersen Birthe D

    2011-06-01

    Full Text Available Abstract Background Growing evidence exists that living with an ICD can lead to fear and avoidance behaviour including the avoidance of physical activity. It has been suggested that psychological stress can increase the risk of shock and predict death. Small studies have indicated a beneficial effect arising from exercise training and psychological intervention, therefore a large-scale rehabilitation programme was set up. Methods/Design A mixed methods embedded experimental design was chosen to include both quantitative and qualitative measures. A randomised clinical trial is its primary component. 196 patients (power-calculated were block randomised to either a control group or intervention group at a single centre. The intervention consists of a 1-year psycho-educational component provided by two nurses and a 12-week exercise training component provided by two physiotherapists. Our hypothesis is that the COPE-ICD programme will reduce avoidance behaviour, sexual dysfunction and increase quality of life, increase physical capability, reduce the number of treatment-demanding arrhythmias, reduce mortality and acute re-hospitalisation, reduce sickness leading to absence from work and be cost-effective. A blinded investigator will perform all physical tests and data collection. Discussion Most participants are men (79% with a mean age of 58 (range 20-85. Most ICD implantations are on primary prophylactic indication (66%. 44% is NYHA II. Mean walk capacity (6MWT is 417 m. Mean perception of General Health (SF-36 is PCS 42.6 and MCS 47.1. A large-scale ICD rehabilitation trial including psycho-educational intervention and exercise training has been initiated and will report findings starting in 2011. Trial Registration ClinicalTrials.gov: NCT00569478

  16. Does ICD indication affect quality of life and levels of distress?

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Sears, Samuel F; Burg, Matthew M

    2009-01-01

    on patients' lives, particularly whether primary prophylaxis implantation may impact adversely on patient-centered outcomes such as quality of life (QoL) and distress. We examined the evidence for a role of ICD indication on these patient-centered outcomes. A literature search was conducted on PubMed and Web......-426 patients across studies, five of seven articles used a prospective design, and follow-up ranged from 2-12 months. No study reported an effect for indication on patient-centered outcomes. There is no evidence to suggest that patients receiving an ICD for primary prophylaxis have subsequent poorer Qo...

  17. The relationship of reactive psychosis and ICD-10 acute and transient psychotic disorders: evidence from a case register-based comparison

    DEFF Research Database (Denmark)

    Castagnini, Augusto; Bertelsen, Aksel; Munk-Jørgensen, Povl

    2006-01-01

    the relationship between the concept of reactive psychosis (RP), equivalent to the ICD-8 298 category of 'other psychoses', and ATPD. SAMPLING AND METHOD: Since January 1, 1994, ICD-10 has replaced ICD-8 as official classification in Denmark. Patients given an ICD-8 298 diagnosis on their last admission in 1992......-1993 were identified from the Danish Psychiatric Central Register, and the ICD-8 diagnoses assigned were compared with their ICD-10 diagnoses when readmitted in 1994-1995. RESULTS: Diagnosis of RP was recorded in 19.2% of patients with functional psychoses in 1992-1993, whereas ATPD overall prevalence...

  18. Consequences of the Diagnostic Criteria Proposed for the ICD-11 on the Prevalence of PTSD in Children and Adolescents.

    Science.gov (United States)

    Sachser, Cedric; Goldbeck, Lutz

    2016-04-01

    In 2013, a working group of the World Health Organization (WHO) proposed a reformulation of the posttraumatic stress disorder (PTSD) diagnostic criteria for the upcoming 11(th) edition of the International Classification of Diseases (ICD-11; Maercker, Brewin, Bryant, Cloitre, van Ommeren, et al., 2013). This study investigated the consequences of the proposed ICD-11 PTSD symptom reduction on the prevalence of PTSD in children and adolescents. Prevalence rates of PTSD in a clinical sample of 159 traumatized children and adolescents were compared applying criteria according to the 4(th) edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-IV; American Psychiatric Association, 1994), the ICD-10 (WHO, 1992), and the ICD-11. The prevalence rate was 76.1% using DSM-IV, 88.1% using ICD-10, and 61.0% using ICD-11. The use of the criteria proposed for ICD-11 resulted in 27.1% less positive cases compared with ICD-10 and 15.1% less positive cases compared with DSM-IV. Our results showed that in a clinical sample of children and adolescents the prevalence of PTSD was significantly affected by the use of different diagnostic systems. This will constitute a major challenge for research and practice because, depending on the algorithm used, different groups of patients will be included in studies and different groups of individuals will be able to access medical care and therapy.

  19. Integration of Attributes from Non-Linear Characterization of Cardiovascular Time-Series for Prediction of Defibrillation Outcomes.

    Directory of Open Access Journals (Sweden)

    Sharad Shandilya

    Full Text Available The timing of defibrillation is mostly at arbitrary intervals during cardio-pulmonary resuscitation (CPR, rather than during intervals when the out-of-hospital cardiac arrest (OOH-CA patient is physiologically primed for successful countershock. Interruptions to CPR may negatively impact defibrillation success. Multiple defibrillations can be associated with decreased post-resuscitation myocardial function. We hypothesize that a more complete picture of the cardiovascular system can be gained through non-linear dynamics and integration of multiple physiologic measures from biomedical signals.Retrospective analysis of 153 anonymized OOH-CA patients who received at least one defibrillation for ventricular fibrillation (VF was undertaken. A machine learning model, termed Multiple Domain Integrative (MDI model, was developed to predict defibrillation success. We explore the rationale for non-linear dynamics and statistically validate heuristics involved in feature extraction for model development. Performance of MDI is then compared to the amplitude spectrum area (AMSA technique.358 defibrillations were evaluated (218 unsuccessful and 140 successful. Non-linear properties (Lyapunov exponent > 0 of the ECG signals indicate a chaotic nature and validate the use of novel non-linear dynamic methods for feature extraction. Classification using MDI yielded ROC-AUC of 83.2% and accuracy of 78.8%, for the model built with ECG data only. Utilizing 10-fold cross-validation, at 80% specificity level, MDI (74% sensitivity outperformed AMSA (53.6% sensitivity. At 90% specificity level, MDI had 68.4% sensitivity while AMSA had 43.3% sensitivity. Integrating available end-tidal carbon dioxide features into MDI, for the available 48 defibrillations, boosted ROC-AUC to 93.8% and accuracy to 83.3% at 80% sensitivity.At clinically relevant sensitivity thresholds, the MDI provides improved performance as compared to AMSA, yielding fewer unsuccessful defibrillations

  20. Designing Shared Electronic Records for Chronic Care

    DEFF Research Database (Denmark)

    Bansler, Jørgen Peter; Havn, Erling C.; Mønsted, Troels

    2010-01-01

    This paper reports preliminary findings from an ongoing research project on the development of IT support for communication and information sharing across institutional and professional boundaries within the Danish healthcare system. The project focuses on the treatment of patients with implanted...... ICDs (implantable cardioverter-defibrillator). These are chronic patients who usually see several different healthcare providers on a regular basis. The main findings so far are: (1) Most of the data produced and recorded as part of the care process are context-specific and often difficult to interpret...

  1. Management of patients with Arrhythmogenic Right Ventricular Cardiomyopathy in the Nordic countries

    DEFF Research Database (Denmark)

    Haugaa, Kristina H; Bundgaard, Henning; Edvardsen, Thor;

    2015-01-01

    are sparse. This paper aims to give a practical overview of management strategies, risk stratification, and selection of appropriate therapies for patients with ARVC and their family members. DESIGN: This paper summarizes follow-up and treatment strategies in ARVC patients in the Nordic countries. The author......-up are required in patients with definite ARVC and in genetic-mutation-positive family members. Furthermore, ARVC patients with and without implantable cardioverter defibrillators (ICDs) require different follow-up strategies. CONCLUSION: Careful follow-up is required in patients with ARVC diagnosis to evaluate...

  2. Radiofrequency ablation for benign thyroid nodules.

    Science.gov (United States)

    Bernardi, S; Stacul, F; Zecchin, M; Dobrinja, C; Zanconati, F; Fabris, B

    2016-09-01

    Benign thyroid nodules are an extremely common occurrence. Radiofrequency ablation (RFA) is gaining ground as an effective technique for their treatment, in case they become symptomatic. Here we review what are the current indications to RFA, its outcomes in terms of efficacy, tolerability, and cost, and also how it compares to the other conventional and experimental treatment modalities for benign thyroid nodules. Moreover, we will also address the issue of treating with this technique patients with cardiac pacemakers (PM) or implantable cardioverter-defibrillators (ICD), as it is a rather frequent occurrence that has never been addressed in detail in the literature.

  3. [Biventricular resynchronization in the management of severe cardiac insufficiency].

    Science.gov (United States)

    Chine, Samira; Kammoun, Ikram; Ben Halima, Afef; Lefi, Abdelatif; Chaabène, Olfa; Zouaoui, Walid; Essmatt, Wajih; Marrakchi, Sonia; Gargouri, Sami; Keskes, Hend; Kachboura, Salem

    2004-01-01

    Heart failure is a major problem of public health, it represents a frequent status among patients with heart disease, and its implications in term of mortality and cost are high. Non Pharmacological treatment of heart failure most commonly designed as cardiac resynchronization therapy (CRT) has demonstrate efficacy to improve functional class, exertion capacity, left ventricular ejection fraction, reduction of mitral regurgitation, and probably mortality at midterm. The most recent studies emphasize on the role of implantable cardioverter defibrillate or (ICD) combined with CRT to reduce mortality. More trials are needed to valid this concept.

  4. DSM-5 AND ICD-11 DEFINITIONS OF POSTTRAUMATIC STRESS DISORDER : INVESTIGATING "NARROW" AND "BROAD" APPROACHES

    NARCIS (Netherlands)

    Stein, Dan J.; McLaughlin, Katie A.; Koenen, Karestan C.; Atwoli, Lukoye; Friedman, Matthew J.; Hill, Eric D.; Maercker, Andreas; Petukhova, Maria; Shahly, Victoria; van Ommeren, Mark; Alonso, Jordi; Borges, Guilherme; de Girolamo, Giovanni; de Jonge, Peter; Demyttenaere, Koen; Florescu, Silvia; Karam, Elie G.; Kawakami, Norito; Matschinger, Herbert; Okoliyski, Michail; Posada-Villa, Jose; Scott, Kate M.; Viana, Maria Carmen; Kessler, Ronald C.

    2014-01-01

    Background: The development of the Diagnostic and Statistical Manual of Mental Disorders 5th edition (DSM-5) and ICD-11 has led to reconsideration of diagnostic criteria for posttraumatic stress disorder (PTSD). The World Mental Health (WMH) Surveys allow investigation of the implications of the cha

  5. Detection of Inpatient Health Care Associated Injuries: Comparing Two ICD-9-CM Code Classifications

    Science.gov (United States)

    2005-05-01

    example, currently the UTIDs database has nine fields for ICD-9-CM diagnosis codes plus a single additional field for an E-code. Some patients...information for physicians on sub-acute thromboses (SAT) and hypersensitivity reactions with use of the Cordis CYPHERTM Sirolimus-eluting coronary stent

  6. Long-term performance of the St Jude Riata 1580-1582 ICD lead family

    NARCIS (Netherlands)

    S.D.A. Valk (Suzanne); D.A.M.J. Theuns (Dominic); L.J.L.M. Jordaens (Luc)

    2013-01-01

    textabstractObjective Safety concerns about the Riata ICD shock lead were recently raised, with insulation failure due to conductor externalisation. Its incidence and presentation were assessed, and predictors of insulation failure and lead survival of the Riata 1580-1582 were studied, retrospective

  7. Prognostic value of tissue Doppler imaging for predicting ventricular arrhythmias and cardiovascular mortality in ischaemic cardiomyopathy

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Olsen, Flemming Javier; Storm, Katrine;

    2016-01-01

    AIMS: Only 30% of patients receiving an implantable cardioverter defibrillator (ICD) for primary prevention receive appropriately therapy. We sought to investigate the value of tissue Doppler imaging (TDI) to predict ventricular tachycardia (VT), ventricular fibrillation (VF), and cardiovascular...... mortality (CVD) in patients with primary prevention ICD. METHODS AND RESULTS: In total, 151 ICD patients meeting primary prevention criteria and with no history of ventricular arrhythmias were included. All participants were examined by conventional 2D echocardiography and TDI echocardiography. Longitudinal...... systolic (s'), early diastolic (e'), and late diastolic (a') myocardial velocities were measured using TDI at six mitral annular sites and averaged to provide global estimates. Forty patients experienced the combined endpoint of VT, VF, or CVD during a median follow-up of 2.3 years. Left ventricular...

  8. Malignant ventricular tachycardia in acromegaly: a case report

    Directory of Open Access Journals (Sweden)

    Zhe An

    Full Text Available CONTEXT: In patients with acromegaly, cardiovascular complications are the main cause of death; sudden death has been associated with ventricular tachyarrhythmias. In other patients with life-threatening malignant ventricular tachyarrhythmias, surgical placement of an implantable cardioverter-defibrillator (ICD has proved highly effective in reducing sudden death rates. CASE REPORT: The present article reports the case of a 50-year-old male acromegalic patient who presented symptoms of syncope induced by ventricular tachycardia. An ICD was surgically implanted and a pituitary adenoma, which was responsible for the acromegaly, was completely removed in the same procedure. The surgery was successful and the ventricular arrhythmias were effectively terminated. During six months of follow-up, no documented arrhythmic episodes occurred. CONCLUSION: In patients with acromegaly, malignant ventricular tachyarrhythmia might be effectively controlled by implantation of an ICD and surgical removal of the pituitary adenoma.

  9. Stratification of the Risk of Sudden Death in Nonischemic Heart Failure

    Directory of Open Access Journals (Sweden)

    Maurício Pimentel

    2014-10-01

    Full Text Available Despite significant therapeutic advancements, heart failure remains a highly prevalent clinical condition associated with significant morbidity and mortality. In 30%-40% patients, the etiology of heart failure is nonischemic. The implantable cardioverter-defibrillator (ICD is capable of preventing sudden death and decreasing total mortality in patients with nonischemic heart failure. However, a significant number of patients receiving ICD do not receive any kind of therapy during follow-up. Moreover, considering the situation in Brazil and several other countries, ICD cannot be implanted in all patients with nonischemic heart failure. Therefore, there is an urgent need to identify patients at an increased risk of sudden death because these would benefit more than patients at a lower risk, despite the presence of heart failure in both risk groups. In this study, the authors review the primary available methods for the stratification of the risk of sudden death in patients with nonischemic heart failure.

  10. Use of Ontology Structure and Bayesian Models to Aid the Crowdsourcing of ICD-11 Sanctioning Rules.

    Science.gov (United States)

    Lou, Yun; Tu, Samson W; Nyulas, Csongor; Tudorache, Tania; Chalmers, Robert J G; Musen, Mark A

    2017-02-10

    The International Classification of Diseases (ICD) is the de facto standard international classification for mortality reporting and for many epidemiological, clinical, and financial use cases. The next version of ICD, ICD-11, will be submitted for approval by the World Health Assembly in 2018. Unlike previous versions of ICD, where coders mostly select single codes from pre-enumerated disease and disorder codes, ICD-11 coding will allow extensive use of multiple codes to give more detailed disease descriptions. For example, "severe malignant neoplasms of left breast" may be coded using the combination of a "stem code" (e.g., code for malignant neoplasms of breast) with a variety of "extension codes" (e.g., codes for laterality and severity). The use of multiple codes (a process called post-coordination), while avoiding the pitfall of having to pre-enumerate vast number of possible disease and qualifier combinations, risks the creation of meaningless expressions that combine stem codes with inappropriate qualifiers. To prevent that from happening, "sanctioning rules" that define legal combinations are necessary. In this work, we developed a crowdsourcing method for obtaining sanctioning rules for the post-coordination of concepts in ICD-11. Our method utilized the hierarchical structures in the domain to improve the accuracy of the sanctioning rules and to lower the crowdsourcing cost. We used Bayesian networks to model crowd workers' skills, the accuracy of their responses, and our confidence in the acquired sanctioning rules. We applied reinforcement learning to develop an agent that constantly adjusted the confidence cutoffs during the crowdsourcing process to maximize the overall quality of sanctioning rules under a fixed budget. Finally, we performed formative evaluations using a skin-disease branch of the draft ICD-11 and demonstrated that the crowd-sourced sanctioning rules replicated those defined by an expert dermatologist with high precision and recall

  11. Less is more? Assessing the validity of the ICD-11 model of PTSD across multiple trauma samples

    Directory of Open Access Journals (Sweden)

    Maj Hansen

    2015-10-01

    Full Text Available Background: In the 5th edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5, the symptom profile of posttraumatic stress disorder (PTSD was expanded to include 20 symptoms. An alternative model of PTSD is outlined in the proposed 11th edition of the International Classification of Diseases (ICD-11 that includes just six symptoms. Objectives and method: The objectives of the current study are: 1 to independently investigate the fit of the ICD-11 model of PTSD, and three DSM-5-based models of PTSD, across seven different trauma samples (N=3,746 using confirmatory factor analysis; 2 to assess the concurrent validity of the ICD-11 model of PTSD; and 3 to determine if there are significant differences in diagnostic rates between the ICD-11 guidelines and the DSM-5 criteria. Results: The ICD-11 model of PTSD was found to provide excellent model fit in six of the seven trauma samples, and tests of factorial invariance showed that the model performs equally well for males and females. DSM-5 models provided poor fit of the data. Concurrent validity was established as the ICD-11 PTSD factors were all moderately to strongly correlated with scores of depression, anxiety, dissociation, and aggression. Levels of association were similar for ICD-11 and DSM-5 suggesting that explanatory power is not affected due to the limited number of items included in the ICD-11 model. Diagnostic rates were significantly lower according to ICD-11 guidelines compared to the DSM-5 criteria. Conclusions: The proposed factor structure of the ICD-11 model of PTSD appears valid across multiple trauma types, possesses good concurrent validity, and is more stringent in terms of diagnosis compared to the DSM-5 criteria.

  12. Metrics and tools for consistent cohort discovery and financial analyses post-transition to ICD-10-CM.

    Science.gov (United States)

    Boyd, Andrew D; Li, Jianrong John; Kenost, Colleen; Joese, Binoy; Yang, Young Min; Kalagidis, Olympia A; Zenku, Ilir; Saner, Donald; Bahroos, Neil; Lussier, Yves A

    2015-05-01

    In the United States, International Classification of Disease Clinical Modification (ICD-9-CM, the ninth revision) diagnosis codes are commonly used to identify patient cohorts and to conduct financial analyses related to disease. In October 2015, the healthcare system of the United States will transition to ICD-10-CM (the tenth revision) diagnosis codes. One challenge posed to clinical researchers and other analysts is conducting diagnosis-related queries across datasets containing both coding schemes. Further, healthcare administrators will manage growth, trends, and strategic planning with these dually-coded datasets. The majority of the ICD-9-CM to ICD-10-CM translations are complex and nonreciprocal, creating convoluted representations and meanings. Similarly, mapping back from ICD-10-CM to ICD-9-CM is equally complex, yet different from mapping forward, as relationships are likewise nonreciprocal. Indeed, 10 of the 21 top clinical categories are complex as 78% of their diagnosis codes are labeled as "convoluted" by our analyses. Analysis and research related to external causes of morbidity, injury, and poisoning will face the greatest challenges due to 41 745 (90%) convolutions and a decrease in the number of codes. We created a web portal tool and translation tables to list all ICD-9-CM diagnosis codes related to the specific input of ICD-10-CM diagnosis codes and their level of complexity: "identity" (reciprocal), "class-to-subclass," "subclass-to-class," "convoluted," or "no mapping." These tools provide guidance on ambiguous and complex translations to reveal where reports or analyses may be challenging to impossible.Web portal: http://www.lussierlab.org/transition-to-ICD9CM/Tables annotated with levels of translation complexity: http://www.lussierlab.org/publications/ICD10to9.

  13. The ERα coactivator, HER4/4ICD, regulates progesterone receptor expression in normal and malignant breast epithelium

    Directory of Open Access Journals (Sweden)

    Howard Beatrice A

    2010-06-01

    Full Text Available Abstract The HER4 intracellular domain (4ICD is a potent estrogen receptor (ERα coactivator with activities in breast cancer and the developing mammary gland that appear to overlap with progesterone receptor (PgR. In fact, 4ICD has recently emerged as an important regulator and predictor of tamoxifen response, a role previously thought to be fulfilled by PgR. Here we investigated the possibility that the 4ICD coactivator regulates PgR expression thereby providing a mechanistic explanation for their partially overlapping activities in breast cancer. We show that 4ICD is both sufficient and necessary to potentiate estrogen stimulation of gene expression. Suppression of HER4/4ICD expression in the MCF-7 breast tumor cell line completely eliminated estrogen stimulated expression of PgR. In addition, the HER4/4ICD negative MCF-7 variant, TamR, failed to express PgR in response to estrogen. Reintroduction of wild-type HER4 but not the γ-secretase processing mutant HER4V673I into the TamR cell line restored PgR expression indicating that 4ICD is an essential PgR coactivator in breast tumor cells. These results were substantiated in vivo using two different physiologically relevant experimental systems. In the mouse mammary gland estrogen regulates expression of PgR-A whereas expression of PgR-B is estrogen independent. Consistent with a role for 4ICD in estrogen regulated PgR expression in vivo, PgR-A, but not PgR-B, expression was abolished in HER4-null mouse mammary glands during pregnancy. Coexpression of PgR and 4ICD is also commonly observed in ERα positive breast carcinomas. Using quantitative AQUA IHC technology we found that 4ICD potentiated PgR expression in primary breast tumors and the highest levels of PgR expression required coexpression of ERα and the 4ICD coactivator. In summary, our results provide compelling evidence that 4ICD is a physiologically important ERα coactivator and 4ICD cooperates with ERα to potentiate PgR expression

  14. Comparison of mechanism of break up and cycle length in defibrillation success

    Science.gov (United States)

    Melkus, Natalya; Puwal, Steffan

    2012-10-01

    Heart fibrillation is an often fatal condition which can be modeled by chaotic electrical activity; spiral waves of electrical activity rotate, break-up, and meander on tissue. As they do, they produce a chaotic distribution of electrical activity, negatively affecting physical contraction (blood pumping). Fenton, et al. studied several mechanisms of this wave breakup, including ``far from tip'' and ``Doppler shift.'' We used Fenton et al.'s mathematical model and the different modes of breakup proposed by Fenton to simulate fibrillation and to determine if the cycle length of the activity or the type of mechanism was more significant in defibrillation. Our data supports the conclusion that the cycle length is the more important factor in defibrillation.

  15. Validation of ICD-9-CM/ICD-10 coding algorithms for the identification of patients with acetaminophen overdose and hepatotoxicity using administrative data

    Directory of Open Access Journals (Sweden)

    Shaheen Abdel

    2007-10-01

    Full Text Available Abstract Background Acetaminophen overdose is the most common cause of acute liver failure (ALF. Our objective was to develop coding algorithms using administrative data for identifying patients with acetaminophen overdose and hepatic complications. Methods Patients hospitalized for acetaminophen overdose were identified using population-based administrative data (1995–2004. Coding algorithms for acetaminophen overdose, hepatotoxicity (alanine aminotransferase >1,000 U/L and ALF (encephalopathy and international normalized ratio >1.5 were derived using chart abstraction data as the reference and logistic regression analyses. Results Of 1,776 potential acetaminophen overdose cases, the charts of 181 patients were reviewed; 139 (77% had confirmed acetaminophen overdose. An algorithm including codes 965.4 (ICD-9-CM and T39.1 (ICD-10 was highly accurate (sensitivity 90% [95% confidence interval 84–94%], specificity 83% [69–93%], positive predictive value 95% [89–98%], negative predictive value 71% [57–83%], c-statistic 0.87 [0.80–0.93]. Algorithms for hepatotoxicity (including codes for hepatic necrosis, toxic hepatitis and encephalopathy and ALF (hepatic necrosis and encephalopathy were also highly predictive (c-statistics = 0.88. The accuracy of the algorithms was not affected by age, gender, or ICD coding system, but the acetaminophen overdose algorithm varied between hospitals (c-statistics 0.84–0.98; P = 0.003. Conclusion Administrative databases can be used to identify patients with acetaminophen overdose and hepatic complications. If externally validated, these algorithms will facilitate investigations of the epidemiology and outcomes of acetaminophen overdose.

  16. 关于Castleman病ICD-10编码的探讨%Discussion on the ICD-10 Coding of Castleman Disease

    Institute of Scientific and Technical Information of China (English)

    赵晶

    2015-01-01

    目的 通过分析Castleman病的原因、病理和临床表现,探讨正确查找castleman病ICD-10编码思路与方法.方法 查阅某院2004年-2014年血液科“淋巴结肿大”为主要诊断的185份病例资料中确诊的castleman病例.分析该病的病因、病理及临床表现,按照国际疾病分类原则,灵活替换不同主导词.结果 对于发病原因不明又没有特异性临床表现的一类疾病,应了解该病的发生、发展过程,与临床医生沟通,详细分析病案情况,寻找其实验室检查、影像学检查、病理组织学检查等相关医学确诊依据,确定该病ICD-10编码局灶性(LCD)为R59.0,多中心型(MCD)为R59.1.结论 Castleman病ICD-10编码的查找,应以“增生、扩大”为主导词,不能简单认定其为肿瘤或淋巴系统疾病,同时认真阅读病案资料,查找其他伴发疾病的编码.

  17. Data bank international of events of failure of common cause ICDE; Banco de datos internacional de sucesos de fallo de causa comum (ICDE)

    Energy Technology Data Exchange (ETDEWEB)

    Morales Castellanos, M. R.; Fernandez Andujar, B.; Pereira Pagan, M. B.

    2013-07-01

    Common Cause Failure (CCF) is a dependent event in which two or more components fail simultaneously or within a short space of time as a direct result of a shared common cause. Due to the low frequency of this type of events, some Member States of the Agency of Nuclear Energy (NEA) of the Organization for Cooperation and Economic Development (OECD) decided to create the project International Common-Cause Failure Data Exchange (ICDE) in order to encourage multilateral cooperation in the collection and analysis of data relating to CCF events.

  18. [Interferences and cardiac pacemakers--defibrillators. Results of in vivo experiments and radio frequencies].

    Science.gov (United States)

    Trigano, J A

    2003-04-01

    Interference with cardiac pacemakers and defibrillators by cellular phone and electronic article surveillance systems is shown in experimental studies with disparate findings. Interaction occurrence in real life is a convincing but rare experience. Device model, distance, power output and technology of the source are different and sometimes uncontrollable factors. As a result it remains difficult to quantify the true incidence of interaction and associated health risk. Nevertheless, simple recommendations commonly help the patients to prevent the interference.

  19. Preparation of Cellulose Nanofibrils from Bamboo Pulp by Mechanical Defibrillation for Their Applications in Biodegradable Composites.

    Science.gov (United States)

    Guimarães, Mario; Botaro, Vagner Roberto; Novack, Kátia Monteiro; Neto, Wilson Pires Flauzino; Mendes, Lourival Marin; Tonoli, Gustavo H D

    2015-09-01

    There is a growing interest in cellulose nanofibrils from renewable sources for various industrial applications. However, there is a lack of information on cellulose arising from bamboo pulps. Nanofibrils from refined bamboo pulps, including bleached, unbleached, and unrefined/unbleached, were obtained by mechanical defibrillation for use in biodegradable composites. The influence of industrial processes, such as pulping and refining of unbleached pulps, as well as of alkali pretreatments and bleaching of refined pulps, on the chemical composition of the samples was analyzed. Morphological, structural, thermal, optical and viscometric properties were investigated as a function of the number of passages of refined/bleached suspensions through a defibrillator. For the unbleached suspensions, the effects of refining and bleaching on the properties of nanofibrils were evaluated, fixing the number of passages through the defibrillator. Microscopic studies demonstrated that nanoscale cellulose fibers were obtained from both pulps, with a higher yield for the refined/bleached and refined/unbleached pulp, at the expense of the unbleached/unrefined pulps. The study showed that, in addition to the effectiveness of the pre-treatments, there was an increase in the production efficiency of nanofibrils, as well as in the transparency of the bleached suspensions, while viscosity, thermal stability and crystallinity had reduced levels as the number of passages through the defibrillator increased, showing a gradual improvement in the transition from the micro- to the nano-scale. The present study contributed to the different methods that are available for the production of bamboo cellulose nanofibrils, which can be used in the production of biodegradable composites for various applications.

  20. Non-linear dynamical signal characterization for prediction of defibrillation success through machine learning

    Directory of Open Access Journals (Sweden)

    Shandilya Sharad

    2012-10-01

    Full Text Available Abstract Background Ventricular Fibrillation (VF is a common presenting dysrhythmia in the setting of cardiac arrest whose main treatment is defibrillation through direct current countershock to achieve return of spontaneous circulation. However, often defibrillation is unsuccessful and may even lead to the transition of VF to more nefarious rhythms such as asystole or pulseless electrical activity. Multiple methods have been proposed for predicting defibrillation success based on examination of the VF waveform. To date, however, no analytical technique has been widely accepted. We developed a unique approach of computational VF waveform analysis, with and without addition of the signal of end-tidal carbon dioxide (PetCO2, using advanced machine learning algorithms. We compare these results with those obtained using the Amplitude Spectral Area (AMSA technique. Methods A total of 90 pre-countershock ECG signals were analyzed form an accessible preshosptial cardiac arrest database. A unified predictive model, based on signal processing and machine learning, was developed with time-series and dual-tree complex wavelet transform features. Upon selection of correlated variables, a parametrically optimized support vector machine (SVM model was trained for predicting outcomes on the test sets. Training and testing was performed with nested 10-fold cross validation and 6–10 features for each test fold. Results The integrative model performs real-time, short-term (7.8 second analysis of the Electrocardiogram (ECG. For a total of 90 signals, 34 successful and 56 unsuccessful defibrillations were classified with an average Accuracy and Receiver Operator Characteristic (ROC Area Under the Curve (AUC of 82.2% and 85%, respectively. Incorporation of the end-tidal carbon dioxide signal boosted Accuracy and ROC AUC to 83.3% and 93.8%, respectively, for a smaller dataset containing 48 signals. VF analysis using AMSA resulted in accuracy and ROC AUC of 64

  1. Evaluating Open-Source Full-Text Search Engines for Matching ICD-10 Codes.

    Science.gov (United States)

    Jurcău, Daniel-Alexandru; Stoicu-Tivadar, Vasile

    2016-01-01

    This research presents the results of evaluating multiple free, open-source engines on matching ICD-10 diagnostic codes via full-text searches. The study investigates what it takes to get an accurate match when searching for a specific diagnostic code. For each code the evaluation starts by extracting the words that make up its text and continues with building full-text search queries from the combinations of these words. The queries are then run against all the ICD-10 codes until a match indicates the code in question as a match with the highest relative score. This method identifies the minimum number of words that must be provided in order for the search engines choose the desired entry. The engines analyzed include a popular Java-based full-text search engine, a lightweight engine written in JavaScript which can even execute on the user's browser, and two popular open-source relational database management systems.

  2. Determination of problematic ICD-9-CM subcategories for further study of coding performance: Delphi method.

    Science.gov (United States)

    Zeng, Xiaoming; Bell, Paul D

    2011-01-01

    In this study, we report on a qualitative method known as the Delphi method, used in the first part of a research study for improving the accuracy and reliability of ICD-9-CM coding. A panel of independent coding experts interacted methodically to determine that the three criteria to identify a problematic ICD-9-CM subcategory for further study were cost, volume, and level of coding confusion caused. The Medicare Provider Analysis and Review (MEDPAR) 2007 fiscal year data set as well as suggestions from the experts were used to identify coding subcategories based on cost and volume data. Next, the panelists performed two rounds of independent ranking before identifying Excisional Debridement as the subcategory that causes the most confusion among coders. As a result, they recommended it for further study aimed at improving coding accuracy and variation. This framework can be adopted at different levels for similar studies in need of a schema for determining problematic subcategories of code sets.

  3. 关于Fahr综合征及其ICD-10编码

    Institute of Scientific and Technical Information of China (English)

    佘璇瑜; 陈丹霞; 陈彩芳

    2011-01-01

    目的 探讨Fahr综合征的ICD-10编码.方法 通过阅读医学文献,深入了解Fahr综合征的临床与病因,按ICD-10分类规则进行编码.结果 对Fahr综合征的的临床与病因有了进一步的认识,并给予相应的编码.结论 编码员一定要按正确操作步骤进行编码,还要阅读病史,有疑问须多方查阅资料进行综合分析,并依据编码原则做出正确编码.

  4. Heart attack

    Science.gov (United States)

    ... Saunders; 2014:chap 51. Read More Arrhythmias Cardiogenic shock Diabetes Hardening of the arteries Heart failure - overview High blood pressure Implantable cardioverter-defibrillator Lipoprotein- ...

  5. Obsessive-compulsive (anankastic) personality disorder: toward the ICD-11 classification

    OpenAIRE

    Naomi A. Fineberg; Samar Reghunandanan; Sangeetha Kolli; Murad Atmaca

    2014-01-01

    Obsessive-compulsive personality disorder (OCPD) is an early-onset disorder characterized by perfectionism, need for control, and cognitive rigidity. Its nosological status is currently under review. Historically, OCPD has been conceptualized as bearing a close relationship with obsessive-compulsive disorder (OCD). In this article, we discuss the diagnosis of OCPD in anticipation of its review for the ICD-11, from the perspective of clinical utility, global applicability, and research plannin...

  6. Identity, personality and their disorders in DSM-V and ICD-10

    OpenAIRE

    Güell, F. (Francisco); Bernacer, J. (Javier); Castro, P.; Murillo, J.I. (José Ignacio)

    2012-01-01

    The terms “identity” and “personality” are frequently used in medical literature in the attempt to classify certain dissociative disorders. The main diagnostic manuals used in psychiatry, the DSM-5 and the ICD-10, use the term “dissociative identity disorder” (DID) and “multiple personality disorder” (MPD) respectively, to define a disruption of identity characterized by two or more distinct personality states, or an experience of possession, as evidenced by discontinuities in sense of self, ...

  7. Functional disorders in the Neurology section of ICD-11: A landmark opportunity.

    Science.gov (United States)

    Stone, Jon; Hallett, Mark; Carson, Alan; Bergen, Donna; Shakir, Raad

    2014-12-09

    Functional disorders are one of the most common diagnoses in neurologic practice, but this is not reflected in current classification systems. The 11th revision of the World Health Organization's International Classification of Diseases (ICD-11) in 2017 offers an opportunity for these disorders to appear within both neurologic and psychiatric categories for the first time. We discuss the rationale for this proposal and highlight the potential benefits for health professionals and patients.

  8. DSM-III DIAGNOSTIC CATEGORIES FOR ICD-9 HYSTERIA: A STUDY ON 103 CASES

    Science.gov (United States)

    Saxena, Shekhar; Pachauri, Ravindra; Wig, Narendra N.

    1986-01-01

    SUMMARY Rediagnosing 103 ICD-9 Hysteria cases on DSM-III, the authors found Conversion Disorder and Atypical Dissociative Disorder to be the most common diagnosis. Somatization Disorder was diagnosed only in 8.7 per ant of cases. Twenty-nine per cent cases received double diagnoses. Limitations of using DSM-III on Hysteria patients are mentioned and a suggestion is made to include a new category of ‘Simple Dissociative Disorder’ in the DSM-III. PMID:21927140

  9. ICD-10 and the clinical features of depressions: data of the CIRCADIAN-I program

    OpenAIRE

    O V Serdyuk; Ovchinnikov, A.; N A Kutuzova; M Y Drobizhev; K Y Retyunsky

    2011-01-01

    The data of the CIRCADIAN-I trial suggest that depressions are unsatisfactorily diagnosed in psychiatric practice. Thus, some of the ICD-10 diagnoses used to denote depressive states (dysthymia, cyclothymia) are made extremely rarely. Only comparatively short-term and reversible vital depressions are considered to be preferred for the categories of affective disorders (F.30-F.33). Any clinical deviations from this clinical presentation (sensitive, anxiety symptoms, a prolonged course, and no ...

  10. Authentication of Algorithm to Detect Metastases in Men with Prostate Cancer Using ICD-9 Codes

    Directory of Open Access Journals (Sweden)

    Matthew T. Dolan

    2012-01-01

    Full Text Available Background. Metastasis is a crucial endpoint for patients with prostate cancer (PCa, but currently lacks a validated claims-based algorithm for detection. Objective. To develop an algorithm using ICD-9 codes to facilitate accurate reporting of PCa metastases. Methods. Medical records from 300 men hospitalized at Robert Wood Johnson University Hospital for PCa were reviewed. Using the presence of metastatic PCa on chart review as the gold standard, two algorithms to detect metastases were compared. Algorithm A used ICD-9 codes 198.5 (bone metastases, 197.0 (lung metastases, 197.7 (liver metastases, or 198.3 (brain and spinal cord metastases to detect metastases, while algorithm B used only 198.5. Sensitivity, specificity, positive predictive value (PPV, and negative predictive value (NPV for the two algorithms were determined. Kappa statistics were used to measure agreement rates between claim data and chart review. Results. Algorithm A demonstrated a sensitivity, specificity, PPV, and NPV of 95%, 100%, 100%, and 98.7%, respectively. Corresponding numbers for algorithm B were 90%, 100%, 100%, and 97.5%, respectively. The agreement rate is 96.8% for algorithm A and 93.5% for algorithm B. Conclusions. Using ICD-9 codes 198.5, 197.0, 197.7, or 198.3 in detecting the presence of PCa metastases offers a high sensitivity, specificity, PPV, and NPV value.

  11. Typical Versus Atypical Anorexia Nervosa Among Adolescents: Clinical Characteristics and Implications for ICD-11.

    Science.gov (United States)

    Silén, Yasmina; Raevuori, Anu; Jüriloo, Elisabeth; Tainio, Veli-Matti; Marttunen, Mauri; Keski-Rahkonen, Anna

    2015-09-01

    There is scant research on the clinical utility of differentiating International Classification of Diseases (ICD) 10 diagnoses F50.0 anorexia nervosa (typical AN) and F50.1 atypical anorexia. We reviewed systematically records of 47 adolescents who fulfilled criteria for ICD-10 F50.0 (n = 34) or F50.1 (n = 13), assessing the impact of diagnostic subtype, comorbidity, background factors and treatment choices on recovery. Atypical AN patients were significantly older (p = 0.03), heavier (minimum body mass index 16.7 vs 15.1 kg/m(2) , p = 0.003) and less prone to comorbidities (38% vs 71%, p = 0.04) and had shorter, less intensive and less costly treatments than typical AN patients. The diagnosis of typical versus atypical AN was the sole significant predictor of treatment success: recovery from atypical AN was 4.3 times (95% confidence interval [1.1, 17.5]) as likely as recovery from typical AN. Overall, our findings indicate that a broader definition of AN may dilute the prognostic value of the diagnosis, and therefore, ICD-11 should retain its distinction between typical and atypical AN.

  12. An evaluation of ICD-11 PTSD and complex PTSD criteria in a sample of adult survivors of childhood institutional abuse

    Directory of Open Access Journals (Sweden)

    Matthias Knefel

    2013-12-01

    Full Text Available Background : The WHO recently launched the proposal for the 11th version of the International Classification of Diseases (ICD-11 that also includes two diagnoses related to traumatic stress. In contrast to the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5, ICD-11 will probably, in addition to posttraumatic stress disorder (PTSD, also define a new diagnosis termed “complex posttraumatic stress disorder” (CPTSD. Objective : We aimed to apply the proposed ICD-11 criteria for PTSD and CPTSD and to compare their prevalence to the ICD-10 (International Classification of Diseases [10th revision] PTSD prevalence. In addition, we compiled a list of symptoms for CPTSD based on subthreshold PTSD so as to include a wider group of individuals. Methods : To evaluate the appropriateness of the WHO ICD-11 proposal compared to the criteria of ICD-10, we applied the newly introduced criteria for PTSD and CPTSD deriving from the Posttraumatic Stress Disorder Checklist – Civilian Version (PCL-C and the Brief Symptom Inventory (BSI scales, to a sample of adult survivors (N=229 of childhood institutional abuse. We evaluated the construct validity of CPTSD using confirmatory factor analysis (CFA. Results : More individuals fulfilled the criteria for PTSD according to ICD-10 (52.8% than the ICD-11 proposal (17% for PTSD only; 38.4% if combined with complex PTSD. The new version of PTSD neutralized the gender effects. The prevalence of CPTSD was 21.4%, and women had a significantly higher rate of CPTSD than men (40.4 and 15.8%, respectively. Those survivors who were diagnosed with CPTSD experienced institutional abuse for a longer time. CFA showed a strong model fit. Conclusion : CPTSD is a highly relevant classification for individuals with complex trauma history, but surprisingly, effects of gender were apparent. Further research should thus address gender effects.

  13. Comparison of ICD-10R, DSM-IV-TR and DSM-5 in an Adult Autism Spectrum Disorder Diagnostic Clinic

    Science.gov (United States)

    Wilson, C. Ellie; Gillan, Nicola; Spain, Deborah; Robertson, Dene; Roberts, Gedeon; Murphy, Clodagh M.; Maltezos, Stefanos; Zinkstok, Janneke; Johnston, Katie; Dardani, Christina; Ohlsen, Chris; Deeley, P. Quinton; Craig, Michael; Mendez, Maria A.; Happé, Francesca; Murphy, Declan G. M.

    2013-01-01

    An Autism Spectrum Disorder (ASD) diagnosis is often used to access services. We investigated whether ASD diagnostic outcome varied when DSM-5 was used compared to ICD-10R and DSM-IV-TR in a clinical sample of 150 intellectually able adults. Of those diagnosed with an ASD using ICD-10R, 56% met DSM-5 ASD criteria. A further 19% met DSM-5 (draft)…

  14. Concordances and discrepancies between ICD-10 and DSM-IV criteria for anxiety disorders in childhood and adolescence

    Directory of Open Access Journals (Sweden)

    Adornetto Carmen

    2012-12-01

    Full Text Available Abstract Background Mental disorders are classified by two major nosological systems, the ICD-10 and the DSM-IV-TR, consisting of different diagnostic criteria. The present study investigated the diagnostic concordance between the two systems for anxiety disorders in childhood and adolescence, in particular for separation anxiety disorder (SAD, specific phobia, social phobia, and generalized anxiety disorder (GAD. Methods A structured clinical interview, the Kinder-DIPS, was administered to 210 children and 258 parents. The percentage of agreement, kappa, and Yule’s Y coefficients were calculated for all diagnoses. Specific criteria causing discrepancies between the two classification systems were identified. Results DSM-IV-TR consistently classified more children than ICD-10 with an anxiety disorder, with a higher concordance between DSM-IV-TR and the ICD-10 child section (F9 than with the adult section (F4 of the ICD-10. This result was found for all four investigated anxiety disorders. The results revealed low to high levels of concordance and poor to good agreement between the classification systems, depending on the anxiety disorder. Conclusions The two classification systems identify different children with an anxiety disorder. However, it remains an open question, whether the research results can be generalized to clinical practice since DSM-IV-TR is mainly used in research while ICD-10 is widely established in clinical practice in Europe. Therefore, the population investigated by the DSM (research population is not identical with the population examined using the ICD (clinical population.

  15. A qualitative study to identify barriers to deployment and student training in the use of automated external defibrillators in schools

    DEFF Research Database (Denmark)

    Zinckernagel, Line; Hansen, Carolina Malta; Rod, Morten Hulvej;

    2017-01-01

    participants, nine school leaders, and 16 teachers at eight different secondary schools in Denmark (2012-2013). Thematic analysis was used to identify regular patterns of meaning using the technology acceptance model and focusing on the concepts of perceived usefulness and perceived ease of use. RESULTS...... is suitable for defibrillator training. They were also ambiguous about deployment of defibrillators at schools. Those only accounting for the risk of students, considering their schools to be small, and that time for professional help was limited, found the relevance to be low. Due to safety concerns, some...

  16. An Ep-ICD based index is a marker of aggressiveness and poor prognosis in thyroid carcinoma.

    Directory of Open Access Journals (Sweden)

    Helen C-H He

    Full Text Available BACKGROUND: Nuclear accumulation of the intracellular domain of epithelial cell adhesion molecule (Ep-ICD in tumor cells was demonstrated to predict poor prognosis in thyroid carcinoma patients in our earlier study. Here, we investigated the clinical significance of Ep-ICD subcellular localization index (ESLI in distinguishing aggressive papillary thyroid carcinoma (PTC from non-aggressive cases. METHODS: Using domain specific antibodies against the intracellular (Ep-ICD and extracellular (EpEx domains of epithelial cell adhesion molecule, 200 archived tissues from a new cohort of patients with benign thyroid disease as well as malignant aggressive and non aggressive PTC were analyzed by immunohistochemistry (IHC. ESLI was defined as sum of the IHC scores for accumulation of nuclear and cytoplasmic Ep-ICD and loss of membranous EpEx; ESLI = [Ep-ICD(nuc + Ep-ICD(cyt + loss of membranous EpEx]. RESULTS: For the benign thyroid tissues, non-aggressive PTC and aggressive PTC, the mean ESLI scores were 4.5, 6.7 and 11 respectively. Immunofluorescence double staining confirmed increased nuclear Ep-ICD accumulation and decreased membrane EpEx expression in aggressive PTC. Receiver-operating characteristic (ROC curve analysis showed an area under the curve (AUC of 0.841, 70.2% sensitivity and 83.9% specificity for nuclear Ep-ICD for differentiating aggressive PTC from non-aggressive PTC. ESLI distinguished aggressive PTC from non-aggressive cases with improved AUC of 0.924, 88.4% sensitivity and 85.5% specificity. Our study confirms nuclear accumulation of Ep-ICD and loss of membranous EpEx occurs in aggressive PTC underscoring the potential of Ep-ICD and ESLI to serve as diagnostic markers for aggressive PTC. Kaplan Meier survival analysis revealed significantly reduced disease free survival (DFS for ESLI positive (cutoff >10 PTC (p<0.05, mean DFS=133 months as compared to 210 months for patients who did not show positive ESLI. CONCLUSION: ESLI

  17. Displacement of death in public space by lay people using the automated external defibrillator.

    Science.gov (United States)

    Timmons, Stephen; Crosbie, Brian; Harrison-Paul, Russell

    2010-03-01

    This paper reports on a study where a technology, the Automated External Defibrillator (AED), enables a socially troubling death in public space to be moved to a more acceptable location. This was a qualitative study, using semi-structured interviews with lay (non-medical) people, in a variety of locations, who had been trained to use an AED. The AED, and its use by lay people, means that the time and place of death from heart attack can be changed from a location like a railway station or shopping centre to the ambulance or hospital. Thus the lay people involved can act as what Timmermans (1999) terms 'death brokers'.

  18. Health Care Utilization and Expenditures Associated With Remote Monitoring in Patients With Implantable Cardiac Devices.

    Science.gov (United States)

    Ladapo, Joseph A; Turakhia, Mintu P; Ryan, Michael P; Mollenkopf, Sarah A; Reynolds, Matthew R

    2016-05-01

    Several randomized trials and decision analysis models have found that remote monitoring may reduce health care utilization and expenditures in patients with cardiac implantable electronic devices (CIEDs), compared with in-office monitoring. However, little is known about the generalizability of these findings to unselected populations in clinical practice. To compare health care utilization and expenditures associated with remote monitoring and in-office monitoring in patients with CIEDs, we used Truven Health MarketScan Commercial Claims and Medicare Supplemental Databases. We selected patients newly implanted with an implantable cardioverter defibrillators (ICD), cardiac resynchronization therapy defibrillator (CRT-D), or permanent pacemaker (PPM), in 2009, who had continuous health plan enrollment 2 years after implantation. Generalized linear models and propensity score matching were used to adjust for confounders and estimate differences in health care utilization and expenditures in patients with remote or in-office monitoring. We identified 1,127; 427; and 1,295 pairs of patients with a similar propensity for receiving an ICD, CRT-D, or PPM, respectively. Remotely monitored patients with ICDs experienced fewer emergency department visits resulting in discharge (p = 0.050). Remote monitoring was associated with lower health care expenditures in office visits among patients with PPMs (p = 0.025) and CRT-Ds (p = 0.006) and lower total inpatient and outpatient expenditures in patients with ICDs (p monitoring of patients with CIEDs may be associated with reductions in health care utilization and expenditures compared with exclusive in-office care.

  19. 常见心绞痛病因及临床表现对ICD-10编码的影响%The Effect of Different Causes and Clinical Manifestation of Angina Pectoris on ICD-10 Classification

    Institute of Scientific and Technical Information of China (English)

    赵桐

    2011-01-01

    目的 探讨心绞痛的病因,以利于对心绞痛进行分型,作出正确的ICD-10编码.方法 对2009年至2010间各种原因引起的心绞痛资料进行回顾性分析.结果 心绞痛根据不同的病因及临床表现可分为不同类型心绞痛,其对应的ICD-10的编码也不同.结论 了解心绞痛的病因及临床表现,正确细分各型心绞痛,是正确进行ICD-10编码最关键环节.%Objective To discuss the causes of angina pectoris, and classify the angina pectoris correctly by ICD-10.Methods The different causes of angina pectoris from 2009 to 2010 were retrospectively analyzed.Results Angina Pectoris can be classified by different causes and clinical manifestation.Therefore, the code of angina pectoris are different.Conclusion Understanding the different causes and clinical manifestation of angina pectoris,and classifying the disease correctly are the key points of ICD-10 classification.

  20. ICD-10 and the clinical features of depressions: data of the CIRCADIAN-I program

    Directory of Open Access Journals (Sweden)

    O V Serdyuk

    2011-01-01

    Full Text Available The data of the CIRCADIAN-I trial suggest that depressions are unsatisfactorily diagnosed in psychiatric practice. Thus, some of the ICD-10 diagnoses used to denote depressive states (dysthymia, cyclothymia are made extremely rarely. Only comparatively short-term and reversible vital depressions are considered to be preferred for the categories of affective disorders (F.30-F.33. Any clinical deviations from this clinical presentation (sensitive, anxiety symptoms, a prolonged course, and no well-defined seasonal and circadian rhythms of mood worsening are regarded as a guide for ruling out the diagnosis of affective disorder. At the same time depressive states are classified as schizophrenia, adjustment disorders, etc.

  1. Autonomic boundary conditions for ventricular fibrillation and their implications for a novel defibrillation technique.

    Science.gov (United States)

    Naggar, Isaac; Uchida, Sae; Kamran, Haroon; Lazar, Jason; Stewart, Mark

    2012-11-01

    The sympathetic and parasympathetic divisions of the autonomic nervous system modulate cardiac rhythm and the probability of arrhythmia occurrence. Both increased sympathetic drive and hypoxia increase the likelihood for ventricular fibrillation (VF). Vagus nerve stimulation (VNS) can protect from fatal arrhythmias via cholinergic and nitrergic action. We sought to determine boundary conditions for VF and defibrillation by autonomic manipulations accompanied or not by hypoxic changes in urethane-anesthetized rats. VF was induced with (1) vagotomy, (2) systemic high-dose (>15 mg/kg) isoproterenol, and (3) hypoxemia. When VNS (50 Hz) produced cardiac standstill, it converted every VF episode (59/59). A nitric oxide synthase inhibitor did not reduce VNS efficacy (13/14 episodes converted), but addition of atropine reduced VNS efficacy (11/27 episodes converted). VF can be induced by autonomic derangements only under constrained conditions, including sympathetic over-activation, reduced parasympathetic input, and hypoxemia. VNS can provide an alternative method to defibrillate via its cholinergic action.

  2. [Recurrent refractory ventricular fibrillation: how many times is it necessary to defibrillate?].

    Science.gov (United States)

    Moreno-Millán, E; Castarnado-Calvo, M; Moreno-Cano, S; Pozuelo-Pozuelo, S

    2010-04-01

    Recurrent ventricular fibrillation is that which persists after three consecutive defibrillation attempts. It generally appears in almost 25% of all heart arrests and entails high mortality. Use of amiodarone during resuscitation maneuvers is recommended, this having better results than lidocaine. Neither procainamide nor bretylium should be used in this type of arrhythmia, however beta blockers or magnesium can be used when ischemic heart disease or hypomagnesiemia, respectively, is suspected as the cause. We present the case of a male patient with a background of heart disease (stent in circunflex 8 years earlier) that began with an episode of primary ventricular fibrillation when entering the Emergency Service. He was given 35 shocks of 360 J, without using thoracic compressions at any time since he recovered an effective post-shock pulse with normal neurological condition. Amiodarone and thrombolytics (tenecteplase) were administered during the intervention, achieving favorable resolution after 52 min, once stabilized showing an electrocardiogram of acute coronary syndrome without ST elevation and verifying obstruction of the right coronary artery in the catheterism, on which a stent was placed. He was discharged from the hospital six days after with no neurological sequels. In agreement with the 2005 International Liaison Committee on Resuscitation Recommendations, the resuscitation maneuvers and electrical shocks should be continued while there is a defibrillable rhythm, as occurred in our patient.

  3. [Factor structure and psychometric properties of the ICD-10-Symptom-Rating (ISR) in samples of psychosomatic patients].

    Science.gov (United States)

    Fischer, Herbert Felix; Tritt, Karin; Klapp, Burghard F; Fliege, Herbert

    2010-08-01

    The ICD-10-Symptom-Rating (ISR) is a self-rating questionnaire for patients. According to its conceptualization, the instrument was developed to closely represent the syndrome structure of the ICD-10 while assessing the extent of psychological distress an individual suffers from. The results of different factor analyses testing the postulated syndrome structure as well as item and scale characteristics are reported here. Data was collected from a consecutive sample of 1 057 psychosomatic patients of the University Hospital Charité Berlin. Evaluation of the dimensional structure of the questionnaire included exploratory and confirmatory factor analyses each computed with a randomized half of the sample. Multi-Sample-Analyses with different subgroups of the sample were performed to test the stability of the factor structure. The individual factors were constituted by the postulated syndrome units of the ICD-10 involving a high and uniform distribution of accounted variance. They also proved themselves satisfactorily stable over the different subsamples. The scales showed a high degree of internal consistency with relatively small gender and age effects, while psychological disorders had a large effect on the means of the scales. Taking a perspective of test theory, the ICD-10-Symptom-Rating is in accordance with the syndrome structure of the ICD-10 and suitable for the assessment of psychological symptoms. Other aspects pertaining to the reliability and validity of the ISR remain to be proven in future research.

  4. 基于ICD-10的药用植物种类统计分析%Statistical Analysis of Medicinal Plants Based on ICD-10

    Institute of Scientific and Technical Information of China (English)

    杨林; 卢大丽; 袁万清; 钱津; 熊源新

    2013-01-01

    A total of 4 258 species of medicinal plants in Guizhou Province, are analyzed according to the Tenth Revision of International Classification of Diseases (ICD - 10) in the current investigation. Dominant families, genera, species of medical plants in Guizhou province are carried out statistical analysis. Twenty one families contain more than 50 species play a role in most diseases. The most proportion of dominant family is Polygonaceae. The genera of the most species including Polygonum, Rubus, Rhododendron etc. The most proportion of dominant genera including Asplenium and Selaginella. Among which 21 species including Aristolo-chia debilis, Polygonum chinense, Croton tiglium and Rhodomyrtus tomentosa etc show curative effect for more than 15 diseases.%根据世界卫生组织ICD-10(《国际疾病分类系统》第十次修订本International Classification of Diseases)的分类内容对贵州4258种药用植物进行了统计分析.对其中涉及疾病最多的科、属、种进行了分析;对重要的科、属、种涉及的疾病也进行了分析.含药用植物种数大于50种的有21科,涉及疾病最多、疾病种类比例最高的科是蓼科Polygonaceae.含药用植物种类最多的属包括蓼属(Polygonum)、悬钩子属(Rubus)、杜鹃花属(Rhododendron)等,涉及疾病种类属的比例最高的是铁角蕨属Asplenium和卷柏属Selaginella.能对15种以上的疾病有疗效的药用植物有21种,包括马兜铃Aristolochia debilis、火炭母Polygonum chinense、巴豆Croton tiglium、桃金娘Rhodomyrtus tomentosa等.

  5. Subclavian Vein Stenosis/Occlusion Following Transvenous Cardiac Pacemaker and Defibrillator Implantation: Incidence, Pathophysiology and Current Management

    Directory of Open Access Journals (Sweden)

    Brian O'Leary

    2015-08-01

    Full Text Available Subclavian vein stenosis is a common, but usually asymptomatic, complication following cardiac device placement. In addition to reviewing the literature on incidence, pathogenesis and management options for this important clinical problem, we describe two cases of symptomatic subclavian vein occlusion following pacemaker/defibrillator placement and successful treatment with venoplasty and stenting.

  6. [Differential diagnostic considerations using ICD-10 in chronic back pain with special regard to persistent somatoform pain disorder with somatic and psychological factors (ICD-10 F45.41)].

    Science.gov (United States)

    Wolff, D

    2016-06-01

    It is often difficult to pass an expert opinion in cases of chronic back pain. This article analyses the differential diagnostic considerations related to coding various causes in line with ICD-10. It emphasises the I importance of making a careful distinction between orthopoedic and psychiatric conditions and disorders. Simultaneous coding of orthopoedic and psychiatric illnesses and disorders based on a distinct cluster of symptoms necessitates an interdisciplinary approach that consistently applies the ICD-10 definitions of mental an behavioural disorders in order to clearly identify the main reason for a functional impairment in the insurance and sociomedical context. Persistant somatoform pain disorder with somatic and psychological factors (ICD-10 F45.41) should be regarded as related to the underlying disease and be used primarily as an additional and descriptive diagnosis.

  7. Queer diagnoses revisited: The past and future of homosexuality and gender diagnoses in DSM and ICD.

    Science.gov (United States)

    Drescher, Jack

    2015-01-01

    The American Psychiatric Association (APA) recently completed a several year process of revising the fifth edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5). During that time, there were objections raised to retaining DSM's gender identity disorder diagnoses and calls to remove them, just as homosexuality had been removed from DSM-II in 1973. At the conclusion of the DSM-5 revision process, the gender diagnoses were retained, albeit in altered form and bearing the new name of 'gender dysphoria'. The author of this paper was a member of the DSM-5 Workgroup on Sexual and Gender Identity Disorders and presently serves on the WHO Working Group on Sexual Disorders and Sexual Health. Both groups faced similar tasks: reconciling patients' needs for access to care with the stigma of being given a psychiatric diagnosis. The differing nature of the two diagnostic manuals led to two different outcomes. As background, this paper updates the history of homosexuality and the gender diagnoses in the DSM and in the International Statistical Classification of Diseases and Related Health Problems (ICD) as well as what is expected to happen to the homosexuality and gender diagnoses following the current ICD-11 revision process.

  8. The exploration of relationship between the surgery grading management and the ICD-9-CM-3 coding

    Directory of Open Access Journals (Sweden)

    Xin-yu FAN

    2014-09-01

    Full Text Available Surgery grading management is one of the key aspects of medical technology access and medical quality management. Surgical classification is graded by risk level, the degree of difficulty of the process and the technology; however, surgery coding is mainly classified by the surgical site. Therefore, the grading of the ICD coding surgical name encounters some difficulties. Our hospital uses the “Jiangsu Province set of medical information classification and coding standards” and “Jiangsu Province surgery hierarchical directory”, which is issued by Jiangsu Provincial Commission of Health and Family Planning, as the basis. We are practicing and exploring about the correspondence between the surgery which has graded and ICD-9-CM-3 encoding, including six categories problems, such as different types of the same operation, different surgeries of the same parts. We carry out the surgical grading and coding intelligent management into hospital management, which will regulate the management of hospital surgery more effectively, ensure the safety of medical quality, and reduce the incidence of adverse events in health care.

  9. Inter-coder agreement for ICD-9-CM coding of stroke.

    Science.gov (United States)

    Leone, M A; Gaviani, P; Ciccone, G

    2006-12-01

    The objective was to evaluate agreement among neurologists for coding stroke, using the International Classification of Diseases 9th Revision - Clinical Modification (ICD-9-CM). Clinical records of 53 consecutive patients (27 stroke or TIA and 26 other diseases) discharged from our general neurology department were coded by four neurology residents, four general neurologists and four neurologists trained in ICD-coding (experts). Inter-coder agreement was evaluated by the kappa statistic. The overall kappa value for coding 430-438 was 0.77 (95% confidence interval 0.70-0.84) for primary (PDx) and 0.82 (0.77-0.88) for PDx+secondary diagnoses (SDx). It was 0.73-0.86 for the residents, 0.78-0.90 for the neurologists and 0.67-0.88 for the experts. The overall kappa values (PDx, SDx) for specific codes were 0.83-0.88 for 431-intracerebral haemorrhage (residents: 0.75-0.89; neurologists: 0.91-0.96; experts: 0.78-0.88) and 0.48-0.51 for 434-occlusion of cerebral arteries) (residents: 0.26-0.26; neurologists: 0.61-0.66; experts: 0.60-0.65). Agreement was substantial for the whole code group 430-438 and higher for code 431 than 434. Reliability was generally improved when both PDx and SDx were considered. Specific training did not increase inter-coders' agreement.

  10. Persisting malnutrition in Chandigarh: decadal underweight trends and impact of ICDS program.

    Science.gov (United States)

    Thakur, Jarnail Singh; Prinja, Shankar; Bhatia, Satpal Singh

    2011-04-01

    Decline in malnutrition levels has been dismal since the 1990s. We ascertained decadal trend in childhood nutritional status between 1997 and 2007 in Chandigarh, India and assessed impact of Integrated Child Development Services (ICDS) on childhood undernutrition. A total of 803 under-five children, 547 children between 12-23 months age, and 218 women with an infant child were recruited for the study. Findings of present study were compared with another methodologically similar study (1997) from Chandigarh and Reproductive and Child Health Rapid Household Survey (1998) to draw decadal trends. Prevalence of underweight among under-five children remained almost stagnant in the last one decade from 51.6%; (1997) to 50.4%; (2007). There was insignificant difference (P=0.3) in prevalence of underweight among children registered under ICDS program (52.1%;) and those not registered (48.4%;) in 2007. Other health and service provision indicators had mixed results in the past decade. Health services utilization was poorest in urban slums.

  11. ICD-9-CM-3 Classification of Hip Replacement and Revision of Hip Replacement%髋关节置换术及置换修复术的ICD-9-CM-3分类

    Institute of Scientific and Technical Information of China (English)

    谭礼萍; 吴晓云; 林佩珊; 谢燕燕; 郑银雄

    2011-01-01

    目的 对髋关节置换术和置换修复术进行合理的ICD-9-CM-3分类.方法 分析临床对髋关节置换术中具体置换方法,与ICD-9-CM-3对该手术的分类进行对比.结果 髋关节置换术、髋关节表面置换术、髋关节置换修复术分类在不同的章节、亚目,各术式又根据不同的置换或修复成分分类在不同的细目.结论 对髋关节置换术及置换修复术进行ICD-9-CM-3编码时要注意髋关节置换的具体成分及其假体的材质,仔细翻阅病例和手术记录,做到准确编码.%Objective To classify hip replacement and Revision of Hip replacement reasonably using ICD-9-CM-3. Methods Analyze the differences between the clinical and ICD-9-CM-3 classification of hip replacement and Revision of Hip replacement. Results The hip replacement resurfacing arthroplasty and replacement prosthesis belong to different subcategories and mini-categories in ICD-9-CM-3. Conclusion The specific composition and prosthetie material of hip replacement and replacement prosthesis should be pay more attention to.

  12. An unusual but reversible cause of ventricular fibrillation.

    Science.gov (United States)

    Merinopoulos, I; Vassiliou, V; Porter, J N; Acton, S; Braganza, D R

    2013-01-01

    A 61-year-old woman was admitted with general malaise, chest pain and breathlessness. During her inpatient stay she sustained a ventricular fibrillation (VF) arrest which was successfully terminated with direct current cardioversion. Cardiac investigations revealed poor left ventricular systolic function but unequivocally normal coronary arteries. During the course of her admission a macular rash developed and following investigations including a renal biopsy, a new diagnosis of systemic lupus erythematosus (SLE) and related myocarditis was reached. First presentation of lupus with myocarditis and VF is uncommon, however reaching the correct diagnosis is important as due to the reversible nature of the condition and improvement in left ventricular systolic function with medical therapy, an implantable cardioverter defibrillator (ICD) might not be appropriate. Our case report demonstrates the importance of screening for reversible conditions when considering ICD therapy for secondary prevention of malignant arrhythmias.

  13. Screening and risk evaluation for sudden cardiac death in ischaemic and non-ischaemic cardiomyopathy

    DEFF Research Database (Denmark)

    Proclemer, Alessandro; Lewalter, Thorsten; Bongiorni, Maria Grazia;

    2013-01-01

    The purpose of this EHRA survey was to examine the current clinical practice of screening and risk evaluation for sudden cardiac death in ischaemic and non-ischaemic cardiomyopathy with a focus on selection of candidates for implantable cardioverter-defibrillator (ICD) therapy, timing of ICD...... centres (32.2%), and in patients with permanent dialysis in 8 centres (33.3%). Signal-averaged electrocardiography and heart rate variability were never considered as risk stratification tools in 23 centres (74.2%). Implantation of a loop recorder was performed in patients with borderline indications...... on the clinical risk stratification and not on non-invasive and invasive diagnostic tests or implantable loop recorder use....

  14. Primary cardiac lymphoma: diagnostic tools and treatment challenges.

    LENUS (Irish Health Repository)

    Bambury, R

    2011-03-01

    Primary cardiac lymphoma (PCL) is a rare malignancy and the optimal treatment strategy remains uncertain. It appears to respond much better to systemic chemotherapy than to surgery and it should be considered in the differential diagnosis of all cardiac tumours before definitive management is undertaken. We report a case of this rare disorder treated successfully with a combination of rituximab and cyclophosphamide, adriamycin, vincristine and prednisolone. The patient developed recurrent unstable ventricular tachycardia (VT) post-chemotherapy secondary to extensive scarring at the tumour site. The tumour as well as the post-treatment scarring is well illustrated by cardiac magnetic resonance imaging highlighting its usefulness in this setting. An implantable cardioverter defibrillator (ICD) was placed. This is only the second case in the literature of PCL to have an ICD placed for recurrent VT. A brief literature review is included.

  15. Idiopathic Intractable Diarrhoea Leading to Torsade de Pointes

    Directory of Open Access Journals (Sweden)

    Kyriacos Mouyis

    2016-01-01

    Full Text Available An 81-year-old lady was admitted to our hospital with a 3-year history of noninfective diarrhoea and recurrent syncopal events over the last 3 months. Her initial electrocardiogram (ECG revealed trigeminy and prolonged QTc interval. She had a structurally normal heart with no coronary artery disease. Investigations revealed low potassium at 3.0 mmol/L. Sigmoidoscopy and colonoscopy suggested a possible diagnosis of diverticulitis. Soon after admission she had an unresponsive episode with spontaneous recovery. Telemetry and Holter analysis confirmed multiple episodes of polymorphic ventricular tachycardia (Torsade de Pointes. Following electrolyte supplementation the episodes of polymorphic VT improved. Due to the protracted nature of the diarrhoea, the recurrent syncopal events, and recurrent hypokalaemia documented over recent years, an Implantable Cardioverter Defibrillator (ICD was sanctioned by the multidisciplinary team (MDT. In summary, chronic diarrhoea may result in life threatening polymorphic VT due to hypokalaemia and QTc prolongation. In these patients an ICD may be considered.

  16. Candida and cardiovascular implantable electronic devices: a case of lead and native aortic valve endocarditis and literature review.

    Science.gov (United States)

    Glavis-Bloom, Justin; Vasher, Scott; Marmor, Meghan; Fine, Antonella B; Chan, Philip A; Tashima, Karen T; Lonks, John R; Kojic, Erna M

    2015-11-01

    Use of cardiovascular implantable electronic devices (CIED), including permanent pacemakers (PPM) and implantable cardioverter defibrillators (ICD), has increased dramatically over the past two decades. Most CIED infections are caused by staphylococci. Fungal causes are rare and their prognosis is poor. To our knowledge, there has not been a previously reported case of multifocal Candida endocarditis involving both a native left-sided heart valve and a CIED lead. Here, we report the case of a 70-year-old patient who presented with nausea, vomiting, and generalised fatigue, and was found to have Candida glabrata endocarditis involving both a native aortic valve and right atrial ICD lead. We review the literature and summarise four additional cases of CIED-associated Candida endocarditis published from 2009 to 2014, updating a previously published review of cases prior to 2009. We additionally review treatment guidelines and discuss management of CIED-associated Candida endocarditis.

  17. DSM-5 AND ICD-11 DEFINITIONS OF POSTTRAUMATIC STRESS DISORDER: INVESTIGATING “NARROW” AND “BROAD” APPROACHES

    Science.gov (United States)

    Stein, Dan J.; McLaughlin, Katie A.; Koenen, Karestan C.; Atwoli, Lukoye; Friedman, Matthew J.; Hill, Eric D.; Maercker, Andreas; Petukhova, Maria; Shahly, Victoria; van Ommeren, Mark; Alonso, Jordi; Borges, Guilherme; de Girolamo, Giovanni; de Jonge, Peter; Demyttenaere, Koen; Florescu, Silvia; Karam, Elie G.; Kawakami, Norito; Matschinger, Herbert; Okoliyski, Michail; Posada-Villa, Jose; Scott, Kate M.; Viana, Maria Carmen; Kessler, Ronald C.

    2014-01-01

    Background The development of the Diagnostic and Statistical Manual of Mental Disorders 5th edition (DSM-5) and ICD-11 has led to reconsideration of diagnostic criteria for posttraumatic stress disorder (PTSD). The World Mental Health (WMH) Surveys allow investigation of the implications of the changing criteria compared to DSM-IV and ICD-10. Methods WMH Surveys in 13 countries asked respondents to enumerate all their lifetime traumatic events (TEs) and randomly selected one TE per respondent for PTSD assessment. DSMIV and ICD-10 PTSD were assessed for the 23,936 respondents who reported lifetime TEs in these surveys with the fully structured Composite International Diagnostic Interview (CIDI). DSM-5 and proposed ICD-11 criteria were approximated. Associations of the different criteria sets with indicators of clinical severity (distress-impairment, suicidality, comorbid fear-distress disorders, PTSD symptom duration) were examined to investigate the implications of using the different systems. Results A total of 5.6% of respondents met criteria for “broadly defined” PTSD (i.e., full criteria in at least one diagnostic system), with prevalence ranging from 3.0% with DSM-5 to 4.4% with ICD-10. Only one-third of broadly defined cases met criteria in all four systems and another one third in only one system (narrowly defined cases). Between-system differences in indicators of clinical severity suggest that ICD-10 criteria are least strict and DSM-IV criteria most strict. The more striking result, though, is that significantly elevated indicators of clinical significance were found even for narrowly defined cases for each of the four diagnostic systems. Conclusions These results argue for a broad definition of PTSD defined by any one of the different systems to capture all clinically significant cases of PTSD in future studies. PMID:24894802

  18. The effect of pinacidil on postshock activation and ventricular defibrillation threshold in canine hearts

    Institute of Scientific and Technical Information of China (English)

    Qi JIN; Ning ZHANG; Jian ZHOU; Chang-jian LIN; Yang PANG; Gang GU; Wei-feng SHEN; Li-qun WU

    2012-01-01

    Aim: To determine the postshock activation patterns with both successful and failed shocks in a canine model of ventricular fibrillation,and whether piniacidil,an early after-depolarization (EAD) inhibitor,altered the defibrillation threshold (DFT) and postshock activation patterns.Methods: In 6 beagles,a basket catheter with 64 unipolar electrodes was placed in the LV for global endocardial mapping,a monophasic action potential catheter was inserted into the LV apex,and a catheter with the negative electrode in the right ventricle and the positive electrode in the superior vena cava was inserted for defibrillation.The DFT,90% action potential duration (APD90) and activation recovery interval (ARI) were evaluated before and after pinacidil administration (loading dosage 0.5 mg/kg and maintenance dosage 0.5 mg·kg-1-h-1,iv).Electrical heterogeneities were defined with the dispersion of ARI.After successful and failed shocks with nearDFT strength,the earliest postshock activation patterns (focal or nonfocal endocardial activation),interval and location were detected.Results: Pinacidil significantly decreased APD90 (from 178±16 ms to 168±18 ms) and ARI from (152±10 ms to 143±10 ms) at pacing cycle length of 300 ms.The drug significantly increased VF activation rate (from 10.0±1.9 Hz to 10.8±2.0 Hz).The drug did not affect the dispersion of ARI,neither it changed DFT (baseline: 480±110 V; pinacidil: 425±55 V,P>O.05).The earliest postshock activation arose locally on the LV apical endocardium before and after the drug treatment.Pinacidil significantly prolonged the postshock cycle length of cycles 2 to 5 for the successful episodes but not for the failed episodes.Conclusion: Pinacidil increases the postshock cycle length suggesting that EAD may play a role in postshock activation,while it fails to alter DFT suggesting that EAD produced by shock does not determine a defibrillation success or failure.

  19. Conversion of ICD-9 (International Classification of Diseases, Ninth Revision) and ICPM (International Classification of Procedures in Medicine) Data to ICD-9-CM with Adaptation to DRGs. Part B.

    Science.gov (United States)

    1987-08-31

    the genitourinary system chapter (codes 580-629) that were not mapped to, yet had some frequencies in NHDS data, were 60499, Other orchitis ...epididymitis, and epididyomo- orchitis , without mention of abscess, and 60784, Impotence of organic origin. The ICD-9 code 6049 was mapped to 60490, Orchitis and

  20. Catatonia from its creation to DSM-V: Considerations for ICD.

    Science.gov (United States)

    Fink, Max

    2011-07-01

    Catatonia was delineated only as a type of schizophrenia in the many American Psychiatric Association DSM classifications and revisions from 1952 until 1994 when "catatonia secondary to a medical condition" was added. Since the 1970s the diagnosis of catatonia has been clarified as a syndrome of rigidity, posturing, mutism, negativism, and other motor signs of acute onset. It is found in about 10% of psychiatric hospital admissions, in patients with depressed and manic mood states and in toxic states. It is quickly treatable to remission by benzodiazepines and by ECT. The DSM-V revision proposes catatonia in two major diagnostic classes, specifiers for 10 principal diagnoses, and deletion of the designation of schizophrenia, catatonic type. This complex recommendation serves no clinical or research purpose and confuses treatment options. Catatonia is best considered in the proposed ICD revision as a unique syndrome of multiple forms warranting a single unique defined class similar to that of delirium.

  1. Evidence for proposed ICD-11 PTSD and complex PTSD: a latent profile analysis

    Directory of Open Access Journals (Sweden)

    Marylène Cloitre

    2013-05-01

    Full Text Available Background: The WHO International Classification of Diseases, 11th version (ICD-11, has proposed two related diagnoses, posttraumatic stress disorder (PTSD and complex PTSD within the spectrum of trauma and stress-related disorders. Objective: To use latent profile analysis (LPA to determine whether there are classes of individuals that are distinguishable according to the PTSD and complex PTSD symptom profiles and to identify potential differences in the type of stressor and severity of impairment associated with each profile. Method: An LPA and related analyses were conducted on 302 individuals who had sought treatment for interpersonal traumas ranging from chronic trauma (e.g., childhood abuse to single-incident events (e.g., exposure to 9/11 attacks. Results: The LPA revealed three classes of individuals: (1 a complex PTSD class defined by elevated PTSD symptoms as well as disturbances in three domains of self-organization: affective dysregulation, negative self-concept, and interpersonal problems; (2 a PTSD class defined by elevated PTSD symptoms but low scores on the three self-organization symptom domains; and (3 a low symptom class defined by low scores on all symptoms and problems. Chronic trauma was more strongly predictive of complex PTSD than PTSD and, conversely, single-event trauma was more strongly predictive of PTSD. In addition, complex PTSD was associated with greater impairment than PTSD. The LPA analysis was completed both with and without individuals with borderline personality disorder (BPD yielding identical results, suggesting the stability of these classes regardless of BPD comorbidity. Conclusion: Preliminary data support the proposed ICD-11 distinction between PTSD and complex PTSD and support the value of testing the clinical utility of this distinction in field trials. Replication of results is necessary.For the abstract or full text in other languages, please see Supplementary files under Article Tools online

  2. Women Literacy and Infant Feeding Practices in Rural Integrated Child Development Scheme (ICDS Block of Delhi

    Directory of Open Access Journals (Sweden)

    Davey Sanjeev , Davey Anuradha

    2012-09-01

    Full Text Available Background: Infant feeding practices have significant effect on the child nutrition, which largely dependent upon the mothers correct knowledge and awareness for the same. Objective: To find out effect of rural women empowerment through literacy on infant feeding practices in an ICDS block. Material and Methodology: Interview of the mothers of registered children up to 6 years in the rural ICDS block for the feeding practices and recording of the weight of those registered children by the salter weighing scale for their nutritional status. Results: Three fourth of the children had received ceremonial feed in the form of honey or gutti and 40 percent of the mothers in our study has discarded colostrums, considering it as ‘bad milk’. Exclusive breast feeding was received by 34.6% children. As literacy level of mothers increased the nutritional status of children was better. This could be because most of the women who are middle school passed or above are non working, so are able to give more time for care and feeding practices. The Severe malnutrition (grade III and IV was evident only in illiterate category of mothers, where 58.7% women were working in unskilled or semiskilled job outside home. Conclusion: Women living in chronic hunger are forced to unskilled jobs for income generation for the family, thereby influencing the feeding practices of their children. In such scenario AWCs and AWWs can be a unique opportunity with their focused approach to take care of severe and moderate malnutrition.

  3. Prolonged grief disorder: Psychometric validation of criteria proposed for DSM-V and ICD-11.

    Directory of Open Access Journals (Sweden)

    Holly G Prigerson

    2009-08-01

    Full Text Available BACKGROUND: Bereavement is a universal experience, and its association with excess morbidity and mortality is well established. Nevertheless, grief becomes a serious health concern for a relative few. For such individuals, intense grief persists, is distressing and disabling, and may meet criteria as a distinct mental disorder. At present, grief is not recognized as a mental disorder in the DSM-IV or ICD-10. The goal of this study was to determine the psychometric validity of criteria for prolonged grief disorder (PGD to enhance the detection and potential treatment of bereaved individuals at heightened risk of persistent distress and dysfunction. METHODS AND FINDINGS: A total of 291 bereaved respondents were interviewed three times, grouped as 0-6, 6-12, and 12-24 mo post-loss. Item response theory (IRT analyses derived the most informative, unbiased PGD symptoms. Combinatoric analyses identified the most sensitive and specific PGD algorithm that was then tested to evaluate its psychometric validity. Criteria require reactions to a significant loss that involve the experience of yearning (e.g., physical or emotional suffering as a result of the desired, but unfulfilled, reunion with the deceased and at least five of the following nine symptoms experienced at least daily or to a disabling degree: feeling emotionally numb, stunned, or that life is meaningless; experiencing mistrust; bitterness over the loss; difficulty accepting the loss; identity confusion; avoidance of the reality of the loss; or difficulty moving on with life. Symptoms must be present at sufficiently high levels at least six mo from the death and be associated with functional impairment. CONCLUSIONS: The criteria set for PGD appear able to identify bereaved persons at heightened risk for enduring distress and dysfunction. The results support the psychometric validity of the criteria for PGD that we propose for inclusion in DSM-V and ICD-11. Please see later in the article for

  4. Fundamentals of intrathoracic impedance monitoring in heart failure.

    Science.gov (United States)

    Wang, Li

    2007-05-21

    The primary objective of the first-generation implantable cardiac pacemakers was to provide critical heart rate support, but these devices did not have any diagnostic capabilities. In the intervening decades, the number, type, and complexity of implantable devices has greatly expanded. Today, implantable devices not only provide heart rate support but they also provide protection from sudden cardiac death with implantable cardioverter defibrillators (ICDs) and reduce symptoms and increase survival with cardiac resynchronization therapy (CRT). Furthermore, information on physiologic variables has been collected in patients with implanted devices for the purpose of providing sophisticated closed-loop optimization of their pacing and defibrillation algorithms. Thoracic fluid status monitoring via intrathoracic impedance is the newest device-based diagnostic capability. For those patients with heart failure who are already targeted to receive an ICD or CRT with defibrillator implant, the ability to monitor fluid status can provide additional insight into the difficult problem of evaluating and managing these patients. This article reviews the basics of measuring intrathoracic impedance via OptiVol fluid status monitoring (Medtronic, Inc., Minneapolis, MN), as well as clinical results regarding the utility of evaluating OptiVol intrathoracic impedance data trends.

  5. Comparison of DSM-IV and proposed ICD-11 formulations of PTSD among civilian survivors of war and war veterans

    NARCIS (Netherlands)

    Morina, N.; van Emmerik, A.A.P.; Andrews, B.; Brewin, C.R.

    2014-01-01

    The World Health Organization recently proposed a reformulation of posttraumatic stress disorder (PTSD) for the 11th edition of the International Classification of Diseases (ICD-11), employing only 6 symptoms. The aim of this study was to investigate the impact of this reformulation of PTSD as compa

  6. Epilepsy is not a disease: proposal for a new approch in the international classification of diseases (ICD

    Directory of Open Access Journals (Sweden)

    Marco Aurélio Smith Filgueiras

    1994-06-01

    Full Text Available What is epilepsy? a disease? a symptom? a syndrome? is it important to define it? Basing his study on an extensive bibliography, the author shows that epilepsy is not a disease. He emphasizes the significance of that definition and suggest a new approach in the International Classification of Diseases (ICD.

  7. A TURBO PASCAL PROGRAM TO CONVERT ICD-9CM CODED INJURY DIAGNOSES INTO INJURY SEVERITY SCORES - ICDTOAIS

    NARCIS (Netherlands)

    KINGMA, J; TENVERGERT, E; WERKMAN, HA; TENDUIS, HJ; KLASEN, HJ

    1994-01-01

    Diagnoses of injuries as a result Of trauma are commonly coded by means of the International Classification of Diseases (9th rev.) Clinical Modification (ICD-9CM). The Abbreviated Injury Scale (AIS) is frequently employed to assess the severity of injury per body region. The Injury Severity Score (I

  8. Asperger's Syndrome: A Comparison of Clinical Diagnoses and Those Made According to the ICD-10 and DSM-IV

    Science.gov (United States)

    Woodbury-Smith, Marc; Klin, Ami; Volkmar, Fred

    2005-01-01

    The diagnostic criteria for Asperger Syndrome (AS) according to ICD-10 and DSM-IV have been criticized as being too narrow in view of the rules of onset and precedence, whereby autism takes precedence over AS in a diagnostic hierarchy. In order to investigate this further, cases from the DSM-IV multicenter study who had been diagnosed clinically…

  9. Predictive Validity of ICD-10 Hyperkinetic Disorder Relative to DSM-IV Attention-Deficit/Hyperactivity Disorder among Younger Children

    Science.gov (United States)

    Lahey, Benjamin B.; Pelham, William E.; Chronis, Andrea; Massetti, Greta; Kipp, Heidi; Ehrhardt, Ashley; Lee, Steve S.

    2006-01-01

    Background: Little is known about the predictive validity of hyperkinetic disorder (HKD) as defined by the Diagnostic Criteria for Research for mental and behavioral disorders of the tenth edition of the International Classification of Diseases (ICD-10; World Health Organization, 1993), particularly when the diagnosis is given to younger children.…

  10. Firing of an Implantable Cardiac Defibrillator: An Unusual Presentation of Celiac Crisis

    Science.gov (United States)

    Katz, Jeffry; Liu, Wendy

    2016-01-01

    Celiac crisis, an atypical presentation of celiac disease, is characterized by acute diarrhea and severe metabolic derangements. This diagnosis is often missed in the differential of acute diarrheal illness. Our patient is a 69-year-old man who presented with ICD firing and was found to have profound metabolic derangements. Further evaluation revealed undiagnosed celiac disease and his symptoms resolved with a gluten-free diet. Celiac crisis should be considered in all patients presenting with acute diarrhea, metabolic acidosis, and severe electrolyte abnormalities as management can be life-saving. PMID:27761475

  11. Operational Assessment of ICDS Scheme at Grass Root Level in a Rural Area of Eastern India: Time to Introspect

    Science.gov (United States)

    Sahoo, Jyotiranjan; Mahajan, Preetam B; Bhatia, Vikas; Patra, Abhinash K; Hembram, Dilip Kumar

    2016-01-01

    Introduction Integrated Child Development Service (ICDS), a flagship program of Government of India (GoI) for early childhood development hasn’t delivered the desired results since its inception four decades ago. This could be due to infrastructural problems, lack of awareness and proper utilization by the local people, inadequate program monitoring and corruption in food supplies, etc. This study is an audit of 36 Anganwadi centres at Khordha district, Odisha, to evaluate the implementation of the ICDS. Aim To assess operational aspects of ICDS program in a rural area of Odisha, in Eastern India. Materials and Methods A total of 36 out of 50 Anganwadi Centres (AWCs) were included in the study. We interviewed the Anganwadi Workers (AWW) and carried out observations on the AWCs using a checklist. We gathered information under three domains manpower resource, material resource and functional aspects of the AWC. Results Most of the AWCs were adequately staffed. Most of the AWWs were well educated. However, more than 85% of the AWCs did not have designated building for daily functioning which resulted in issues related to implementation of program. Water, toilet and electricity facilities were almost non-existent. Indoor air pollution posed a serious threat to the health of the children. Lack of play materials; lack of health assessment tools for promoting, monitoring physical and mental development; and multiple de-motivating factors within the work environment, eventually translated into lack of faith among the beneficiaries in the rural community. Conclusion Inadequate infrastructure and logistic supply were the most prominent issues found, which resulted in poor implementation of ICDS program. Strengthening of grass root level facilities based on need assessment, effective monitoring and supervision will definitely help in revamping the ICDS program in rural areas. PMID:28208890

  12. Establishing cause of maternal death in Malawi via facility-based review and application of the ICD-MM classification.

    Science.gov (United States)

    Owolabi, H; Ameh, C A; Bar-Zeev, S; Adaji, S; Kachale, F; van den Broek, N

    2014-09-01

    Maternal death review (MDR) is an accepted process that is implemented across Malawi and 'underlying cause of death' is assigned by healthcare providers using a standard MDR form. Mixed-methods approach. Key informant interviews with eight stakeholders involved in MDR. Secondary analysis of MDR forms for 54 maternal deaths. Comparison of assigned cause of death by healthcare providers conducting MDR at health facility level with cause assigned by researchers using the International Classification of Diseases Maternal Mortality (ICD-MM) classification. MDR teams, analysts and policymakers reported facing challenges in completing the forms, analysing and using information. The concepts of underlying (primary) and contributing (secondary) causes of death are often misunderstood. Healthcare providers using only MDR forms reported cause of death as non-obstetric complications in 39.6% and pregnancy-related infection in 11.3% of cases. For 30.2% of cases, no clear clinical cause of death was recorded. The most commonly assigned underlying cause of death using ICD-MM was obstetric haemorrhage (32.1%), non-obstetric complications (24.5%) and pregnancy-related infection (22.6%). There was poor agreement between cause(s) of maternal death assigned by healthcare providers in the field and trained researchers using the new ICD-MM classification (κ statistic; 0.219). The majority of cases could be reclassified using the ICD-MM and this provided a more specific cause of death. A more structured and user-friendly MDR form is required. Accurate classification of cause of death is important. Dissemination of, and training in the use of the new ICD-MM classification system will be helpful to healthcare providers conducting MDR in Malawi.

  13. AN EVALUATION OF PRIMARY IMMUNIZATION COVERAGE AMONG ICDS CHILDREN UNDER URBAN FIELD PRACTICE AREA OF OSMANIA MEDICAL COLLEGE, HYDERABAD

    Directory of Open Access Journals (Sweden)

    Mohd

    2014-01-01

    Full Text Available Research question : What is the Primary Immunization Coverage of Anganwadi children (12 - 72 months under Urban Field Practice area of Osmania Medical College? BACKGROUND: Vaccine - preventable diseases are responsible for about 25%of the 10 million deaths occurring annually among children under 5 years of age. Immunization is a proven tool for controlling and eliminating life - threatening infectious diseases and it is estimated that more than 2 million child deaths were averted through immunization in 2003.Immunization is one of the important services which is being provided under ICDS (Integrated Child Development Scheme projects. OBJECTIVES: 1. To Estimate Primar y Immunization Coverage of Anganwadi children (12 - 72 months age group under Urban ICDS project.2. To Estimate Gender inequality ratio (GIR among Study group. METHODOLOGY: It’s a Community based cross sectional Study conducted in Anganwadi Centre of Urban ICDS Project among 340 children (12 - 72 months age group. RESULTS : Children in the age group of 12 - 23 months are more fully immunized when compared to any other age group of children. Males are comparatively more immunized than females. Mother’s education had significant impact on immunization of their children (P˂ 0.05.Primary Immunization coverage is over 85% among study groups. CONCLUSION : The present study showed that there is a better immunization coverage in Urban ICDS project areas. The study also showed that there has been an improvement over few years about immunization taking place in Urban ICDS projects. There is Gender inequality still exist in our country. Maternal Education had positive relation with immunization of their children.

  14. Obese Patients Defibrillation Failure in 1 Cases%肥胖患者电除颤失败1例

    Institute of Scientific and Technical Information of China (English)

    赵莹; 吴浩

    2014-01-01

    利用除颤仪对某螳发生严重快速性异位性心律失常的心脏实施电击,借以消除这些心律失常。称作电除颤(也叫电复律)。在电除颤时。除颤仪释放强大的瞬时电脉冲,使全部心肌在同一时间完成除极,导致心律失常的异常兴奋灶及折返环被完全"消灭"。全部心肌在瞬问处于心电静止状态。这样窦房结就获得了重新主导心脏节律的机会。%Using the defibril ation apparatus of a serious rapidity of gladiator ectopic ar hythmias of cardiac shock, so as to eliminate these arrhythmia. Cal ed electric defibril ation (also cal ed cardioerter). When the electrical shock. Defibril ation apparatus release strong instantaneous electrical impulses, making al the myocardium in addition to the tasks at the same time, cause ar hythmia very excited and exhumation ring oven is completely"destroy". Al the myocardial instantaneous asked in ecg stationary state. The sinoatrial node have a new chance to dominate the heart rhythm.

  15. Decalogue of electric defibrillation Decálogo de la desfibrilación eléctrica

    Directory of Open Access Journals (Sweden)

    Elkín Ferdinand Cardona Duque

    2001-03-01

    Full Text Available Defibrillation is an emergency procedure and the only effective therapy for ventricular fibrillation. Electrical defibrillation delivers large amounts of current to the myocardium and thus depolarizes it, terminating ventricular fibrillation and other arrhythmias. A defibrillator is a device that administers a controlled electrical shock, allowing the operator to select a variable current at the precise moment, according to patient‘s condition. Understanding defibrillator‘s operation leads to more effective resuscitation rates and more therapeutic alternatives in patients with any cardiac electric disturbance. La desfibrilación es un procedimiento de emergencia y es la única terapia efectiva para el manejo de la fibrilación ventricular. La desfibrilación eléctrica libera corriente en gran cantidad al miocardio, despolarizándolo y terminando la fibrilación ventricular y otras arritmias. Un desfibrilador es un aparato que suministra un choque eléctrico en forma controlada, permitiendo al operador seleccionar una corriente variable en el momento oportuno, de acuerdo con la condición del paciente. El entendimiento del manejo del desfibrilador permite tasas de resucitación más efectivas y más alternativas terapéuticas en pacientes con trastornos del ritmo cardíaco.

  16. Causes and prevention of sudden cardiac death in the elderly.

    Science.gov (United States)

    Tung, Patricia; Albert, Christine M

    2013-03-01

    Sudden cardiac death (SCD) is a major cause of mortality in elderly individuals owing to a high prevalence of coronary heart disease, systolic dysfunction, and congestive heart failure (CHF). Although the incidence of SCD increases with age, the proportion of cardiac deaths that are sudden decreases owing to high numbers of other cardiac causes of death in elderly individuals. Implantable cardioverter-defibrillator (ICD) therapy has been demonstrated to improve survival and prevent SCD in selected patients with systolic dysfunction and CHF. However, ICD therapy in elderly patients might not be effective because of a greater rate of pulseless electrical activity underlying SCD and other competing nonarrhythmic causes of death in this population. Although under-represented in randomized trials of ICD use, elderly patients comprise a substantial proportion of the population that qualifies for and receives an ICD for primary prevention under current guidelines. Cardiac resynchronization therapy (CRT), which has been demonstrated to reduce mortality in selected populations with heart failure, is also more commonly used in this group of patients than in younger individuals. In this Review, we examine the causes of SCD in elderly individuals, and discuss the existing evidence for effectiveness of ICD therapy and CRT in this growing population.

  17. Immunohistochemical analysis based Ep-ICD subcellular localization index (ESLI is a novel marker for metastatic papillary thyroid microcarcinoma

    Directory of Open Access Journals (Sweden)

    Kunavisarut Tada

    2012-11-01

    Full Text Available Abstract Background Thyroid cancer is among the fastest growing malignancies; almost fifty-percent of these rapidly increasing incidence tumors are less than or equal to 1cm in size, termed papillary thyroid microcarcinoma (PTMC. The management of PTMC remains a controversy due to differing natural history of these patients. Epithelial cell adhesion molecule (EpCAM is comprised of an extracellular domain (EpEx, a single transmembrane domain and an intracellular domain (Ep-ICD. Our group reported nuclear Ep-ICD correlated with poor prognosis in thyroid cancer (Ralhan et al., BMC Cancer 2010,10:331. Here in, we hypothesized nuclear and cytoplasmic accumulation of Ep-ICD and loss of membranous EpEx may aid in distinguishing metastatic from non-metastatic PTMC, which is an important current clinical challenge. To test our hypothesis, Ep-ICD and EpEx expression levels were analyzed in PTMC and the staining was correlated with metastatic potential of these carcinomas. Methods Thirty-six PTMC patients (tumor size 0.5 - 1cm; metastatic 8 cases and non-metastatic 28 cases who underwent total thyroidectomy were selected. The metastatic group consisted of patients who developed lymph node or distant metastasis at diagnosis or during follow up. The patients’ tissues were stained for Ep-ICD and EpEx using domain specific antibodies by immunohistochemistry and evaluated. Results PTMC patients with metastasis had higher scores for nuclear and cytoplasmic Ep-ICD immunostaining than the patients without metastasis (1.96 ± 0.86 vs. 1.22 ± 0.45; p = 0.007 and 5.37 ± 0.33 vs. 4.72 ± 1.07; p = 0.016, respectively. Concomitantly, the former had lower scores for membrane EpEx than the non-metastatic group (4.64 ± 1.08 vs. 5.64 ± 1.51; p = 0.026. An index of aggressiveness, Ep-ICD subcellular localization index (ESLI, was defined as sum of the IHC scores for accumulation of nuclear and cytoplasmic Ep-ICD and loss of

  18. Slowing of electrical activity in ventricular fibrillation is not associated with increased defibrillation energies in the isolated rabbit heart

    Directory of Open Access Journals (Sweden)

    Jane eCaldwell

    2011-04-01

    Full Text Available Prolonged out-of-hospital ventricular fibrillation (VF arrests are associated with reduced ECG dominant frequency (DF and diminished defibrillation success. Partial reversal of ischaemia increases ECG DF and improves defibrillation outcome. We have investigated the metabolic components of ischaemia responsible for the decline in ECG DF and defibrillation success.Isolated Langendorff-perfused rabbit hearts were loaded with the voltage-sensitive dye RH237. Using a photodiode array, epicardial membrane potentials were recorded at 252 sites (15x15mm on the anterior surface of the left & right ventricles. Simultaneously, a global ECG was recorded. VF was induced by burst pacing, and after 60s, perfusion was either reduced to 6ml/min or the perfusate composition changed to impose hypoxia (95%N2/5%CO2, pH 6.7 (80%O2/20%CO2, or hyperkalaemia (8mM. Using Fast Fourier Transform, power spectra were created from the optical signals and the global ECG. The optical power spectra were summated to give a global power spectrum (pseudoECG. At 600s the minimum defibrillation voltage (MDV was determined by step-up protocol.During VF, the ECG and pseudoECG DF were reduced by low-flow ischaemia (9.0±1.0Hz, p<0.01, n=5 and raised [K+]o (12.2±1.3 Hz, p<0.05, n=7 compared to control (19.2±1.5 Hz, n=20, but were unaffected by acidic pHo (16.7±1.1 Hz, n=11 and hypoxia (14.0±1.2 Hz, n=10. In contrast, the MDV was raised by acidic pH (156.1±26.4V, p<0.001 and hypoxia (154.1±22.1V, p<0.01 compared to control (65.6±2.3V, but comparable changes were not observed in low-flow ischaemia (61.0±0.5V or raised [K+]o (56±3V. In summary, different metabolites are responsible for the reduction in DF and the increase in defibrillation energy during ischaemic VF.

  19. Low Energy Multi-Stage Atrial Defibrillation Therapy Terminates Atrial Fibrillation with Less Energy than a Single Shock

    Science.gov (United States)

    Li, Wenwen; Janardhan, Ajit H.; Fedorov, Vadim V.; Sha, Qun; Schuessler, Richard B.; Efimov, Igor R.

    2011-01-01

    Background Implantable device therapy of atrial fibrillation (AF) is limited by pain from high-energy shocks. We developed a low-energy multi-stage defibrillation therapy and tested it in a canine model of AF. Methods and Results AF was induced by burst pacing during vagus nerve stimulation. Our novel defibrillation therapy consisted of three stages: ST1 (1-4 low energy biphasic shocks), ST2 (6-10 ultra-low energy monophasic shocks), and ST3 (anti-tachycardia pacing). Firstly, ST1 testing compared single or multiple monophasic (MP) and biphasic (BP) shocks. Secondly, several multi-stage therapies were tested: ST1 versus ST1+ST3 versus ST1+ST2+ST3. Thirdly, three shock vectors were compared: superior vena cava to distal coronary sinus (SVC>CSd), proximal coronary sinus to left atrial appendage (CSp>LAA) and right atrial appendage to left atrial appendage (RAA>LAA). The atrial defibrillation threshold (DFT) of 1BP shock was less than 1MP shock (0.55 ± 0.1 versus 1.38 ± 0.31 J; p =0.003). 2-3 BP shocks terminated AF with lower peak voltage than 1BP or 1MP shock and with lower atrial DFT than 4 BP shocks. Compared to ST1 therapy alone, ST1+ST3 lowered the atrial DFT moderately (0.51 ± 0.46 versus 0.95 ± 0.32 J; p = 0.036) while a three-stage therapy, ST1+ST2+ST3, dramatically lowered the atrial DFT (0.19 ± 0.12 J versus 0.95 ± 0.32 J for ST1 alone, p=0.0012). Finally, the three-stage therapy ST1+ST2+ST3 was equally effective for all studied vectors. Conclusions Three-stage electrotherapy significantly reduces the AF defibrillation threshold and opens the door to low energy atrial defibrillation at or below the pain threshold. PMID:21980076

  20. 膀胱癌膀胱全切术ICD-9-CM-3编码研究%ICD-9-CM-3 Coding Research of Bladder Cancer noma Radical Cystectomy

    Institute of Scientific and Technical Information of China (English)

    范炜然; 王建玥; 张磊; 林海丽

    2011-01-01

    目的 探讨膀胱癌膀胱全切术及尿流改道术ICD-9-CM-3分类编码.方法 总结临床常用的膀胱癌膀胱全切术及尿流改道术的手术方式,根据(ICD-9-CM-3(2008版)对所做手术进行编码.结论 疾病分类的工作人员应熟练掌握手术操作编码的原则,同时应了解各种手术的方法,仔细阅读手术记录,经常与临床医师沟通以求准确编码,以满足临床医教研和职能部门的统计需要.%Objective to discuss ICD-9-CM-3 classification coding of bladder cancer noma radical cystectomy and urinary division. Methods a summary on clinical common bladder cancer noma radical cystectomy and urinary division operation mode, according to No. Ninth Clinical Revised Edition Surgery and Operation of International Diseases Classification (ICD-9-CM-3 2008 edition), to code operation. Conclusions disease classification staffs should know well about the principle of operation coding and ways of operation, who should read carefully about operation records and communicate with clinical doctors for correct coding in order to satisfy the statistical requirement of clinical teaching and research and function departments.