  1. Optimal Implantable Cardioverter Defibrillator Programming.

    Science.gov (United States)

    Shah, Bindi K

    Optimal programming of implantable cardioverter defibrillators (ICDs) is essential to appropriately treat ventricular tachyarrhythmias and to avoid unnecessary and inappropriate shocks. There have been a series of large clinical trials evaluating tailored programming of ICDs. We reviewed the clinical trials evaluating ICD therapies and detection, and the consensus statement on ICD programming. In doing so, we found that prolonged ICD detection times, higher rate cutoffs, and antitachycardia pacing (ATP) programming decreases inappropriate and painful therapies in a primary prevention population. The use of supraventricular tachyarrhythmia discriminators can also decrease inappropriate shocks. Tailored ICD programming using the knowledge gained from recent ICD trials can decrease inappropriate and unnecessary ICD therapies and decrease mortality.

  2. An Entirely Subcutaneous Implantable Cardioverter-Defibrillator

    NARCIS (Netherlands)

    Bardy, Gust H.; Smith, Warren M.; Hood, Margaret A.; Crozier, Ian G.; Melton, Iain C.; Jordaens, Luc; Theuns, Dominic; Park, Robert E.; Wright, David J.; Connelly, Derek T.; Fynn, Simon P.; Murgatroyd, Francis D.; Sperzel, Johannes; Neuzner, Joerg; Spitzer, Stefan G.; Ardashev, Andrey V.; Oduro, Amo; Boersma, Lucas; Maass, Alexander H.; Van Gelder, Isabelle C.; Wilde, Arthur A.; van Dessel, Pascal F.; Knops, Reinoud E.; Barr, Craig S.; Lupo, Pierpaolo; Cappato, Riccardo; Grace, Andrew A.

    2010-01-01

    BACKGROUND Implantable cardioverter-defibrillators (ICDs) prevent sudden death from cardiac causes in selected patients but require the use of transvenous lead systems. To eliminate the need for venous access, we designed and tested an entirely subcutaneous ICD system. METHODS First, we conducted tw

  3. An entirely subcutaneous implantable cardioverter-defibrillator

    NARCIS (Netherlands)

    G.H. Bardy (Gust); W.M. Smith (Warren); A.M. Hood (Margaret); I.G. Crozier (Ian); I.C. Melton (Iain Craig); L.J.L.M. Jordaens (Luc); D.A.M.J. Theuns (Dominic); E. Park (Robert); D.J. Wright (David Justin); D.T. Connelly (Derek); S.P. Fynn (Simon Patrick); F.D. Murgatroyd (Francis); J. Sperzel (Johannes); J. Neuzner (Jörg); S.G. Spitzer (Stefan); A.V. Ardashev (Andrey); A. Oduro (Amo); L. Boersma (Lucas); A.H. Maass (Alexander); I.C. van Gelder (Isabelle); A.A.M. Wilde (Arthur); P.F.H.M. van Pascal; R.E. Knops (Reinoud); C.S. Barr (Craig); P. Lupo (Pierpaolo); R. Cappato (Riccardo); A.A. Grace (Andrew)

    2010-01-01

    textabstractBACKGROUND: Implantable cardioverter-defibrillators (ICDs) prevent sudden death from cardiac causes in selected patients but require the use of transvenous lead systems. To eliminate the need for venous access, we designed and tested an entirely subcutaneous ICD system. METHODS: First, w

  4. An entirely subcutaneous implantable cardioverter-defibrillator

    NARCIS (Netherlands)

    G.H. Bardy (Gust); W.M. Smith (Warren); A.M. Hood (Margaret); I.G. Crozier (Ian); I.C. Melton (Iain Craig); L.J.L.M. Jordaens (Luc); D.A.M.J. Theuns (Dominic); E. Park (Robert); D.J. Wright (David Justin); D.T. Connelly (Derek); S.P. Fynn (Simon Patrick); F.D. Murgatroyd (Francis); J. Sperzel (Johannes); J. Neuzner (Jörg); S.G. Spitzer (Stefan); A.V. Ardashev (Andrey); A. Oduro (Amo); L. Boersma (Lucas); A.H. Maass (Alexander); I.C. van Gelder (Isabelle); A.A.M. Wilde (Arthur); P.F.H.M. van Pascal; R.E. Knops (Reinoud); C.S. Barr (Craig); P. Lupo (Pierpaolo); R. Cappato (Riccardo); A.A. Grace (Andrew)

    2010-01-01

    textabstractBACKGROUND: Implantable cardioverter-defibrillators (ICDs) prevent sudden death from cardiac causes in selected patients but require the use of transvenous lead systems. To eliminate the need for venous access, we designed and tested an entirely subcutaneous ICD system. METHODS: First,

  5. An Entirely Subcutaneous Implantable Cardioverter-Defibrillator

    NARCIS (Netherlands)

    Bardy, Gust H.; Smith, Warren M.; Hood, Margaret A.; Crozier, Ian G.; Melton, Iain C.; Jordaens, Luc; Theuns, Dominic; Park, Robert E.; Wright, David J.; Connelly, Derek T.; Fynn, Simon P.; Murgatroyd, Francis D.; Sperzel, Johannes; Neuzner, Joerg; Spitzer, Stefan G.; Ardashev, Andrey V.; Oduro, Amo; Boersma, Lucas; Maass, Alexander H.; Van Gelder, Isabelle C.; Wilde, Arthur A.; van Dessel, Pascal F.; Knops, Reinoud E.; Barr, Craig S.; Lupo, Pierpaolo; Cappato, Riccardo; Grace, Andrew A.

    2010-01-01

    BACKGROUND Implantable cardioverter-defibrillators (ICDs) prevent sudden death from cardiac causes in selected patients but require the use of transvenous lead systems. To eliminate the need for venous access, we designed and tested an entirely subcutaneous ICD system. METHODS First, we conducted

  6. [The implantable cardioverter-defibrillator: sometimes necessary

    NARCIS (Netherlands)

    Smeets, J.L.R.M.

    2004-01-01

    The implantable cardioverter-defibrillator (ICD) is used in patients who are at risk for ventricular fibrillation after having suffered from a myocardial infarction. Initially, patient selection was limited to survivors of impending sudden death with coronary artery disease. Later, ICD implantation

  7. Concerns about the implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van Domburg, Ron T; Theuns, Dominic A M J

    2005-01-01

    Patients with an implantable cardioverter defibrillator (ICD) are at increased risk of anxiety disorders. In turn, anxiety has been identified as a precipitant of ventricular arrhythmias. Anxiety may in part be attributed to concerns about the ICD firing, but the relationship between ICD concerns...

  8. Living with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S; Knudsen, Charlotte; Dilling, Karen;

    2017-01-01

    Hospital were asked to complete a purpose-designed and standardized set of questionnaires. The level of satisfaction with information provision was high; only 13.1% were dissatisfied. Psychological support for patients (39.9%), their relatives (43.1%), and deactivation of the ICD towards end of life (47......AIMS: The clinical management and care of patients with an implantable cardioverter defibrillator (ICD) has shifted from face-to-face in-clinic visits to remote monitoring. Reduced interactions between patients and healthcare professionals may impede patients' transition to adapting post......-implant. We examined patients' needs and preferences for information provision and care options and overall satisfaction with treatment. METHODS AND RESULTS: Patients implanted with a first-time ICD or defibrillator with cardiac resynchronization therapy (n = 389) within the last 2 years at Odense University...

  9. The wearable cardioverter-defibrillator: current technology and evolving indications.

    Science.gov (United States)

    Reek, Sven; Burri, Haran; Roberts, Paul R; Perings, Christian; Epstein, Andrew E; Klein, Helmut U

    2016-10-04

    The wearable cardioverter-defibrillator has been available for over a decade and now is frequently prescribed for patients deemed at high arrhythmic risk in whom the underlying pathology is potentially reversible or who are awaiting an implantable cardioverter-defibrillator. The use of the wearable cardioverter-defibrillator is included in the new 2015 ESC guidelines for the management of ventricular arrhythmias and prevention of sudden cardiac death. The present review provides insight into the current technology and an overview of this approach.

  10. Sexual Health for Patients with an Implantable Cardioverter Defibrillator

    Science.gov (United States)

    ... of the American Heart Association Cardiology Patient Page Sexual Health for Patients With an Implantable Cardioverter Defibrillator ... possible strategies for effective management. Barriers to Healthy Sexual Functioning in ICD Patients Despite limited research regarding ...

  11. Implantable cardioverter defibrillator specific rehabilitation improves health cost outcomes

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Zwisler, Ann-Dorthe; Koch, Mette Bjerrum;

    2015-01-01

    ) were randomized (1:1) to comprehensive cardiac rehabilitation or usual care. Outcomes were measured by implantable cardioverter defibrillator therapy history from patient records and national register follow-up on mortality, hospital admissions and costs. RESULTS: No significant differences were found...... was -6,789 USD/-5,593 Euro in favour of rehabilitation. CONCLUSION: No long-term health outcome benefits were found for the rehabilitation programme. However, the rehabilitation programme resulted in a reduction in total attributable direct costs.......OBJECTIVE: The Copenhagen Outpatient ProgrammE - implantable cardioverter defibrillator (COPE-ICD) trial included patients with implantable cardioverter defibrillators in a randomized controlled trial of rehabilitation. After 6-12 months significant differences were found in favour...

  12. Implantable cardioverter defibrillator specific rehabilitation improves health cost outcomes

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Zwisler, Ann-Dorthe; Koch, Mette Bjerrum

    2015-01-01

    of the rehabilitation group for exercise capacity, general and mental health. The aim of this paper is to explore the long-term health effects and cost implications associated with the rehabilitation programme; more specifically, (i) to compare implantable cardioverter defibrillator therapy history and mortality...... between rehabilitation and usual care groups; (ii) to examine the difference between rehabilitation and usual care groups in terms of time to first admission; and (iii) to determine attributable direct costs. METHODS: Patients with first-time implantable cardioverter defibrillator implantation (n = 196......) were randomized (1:1) to comprehensive cardiac rehabilitation or usual care. Outcomes were measured by implantable cardioverter defibrillator therapy history from patient records and national register follow-up on mortality, hospital admissions and costs. RESULTS: No significant differences were found...

  13. Pacemakers and implantable cardioverter defibrillators - general and anesthetic considerations

    Directory of Open Access Journals (Sweden)

    Amy G. Rapsang

    2014-06-01

    Full Text Available A pacemaking system consists of an impulse generator and lead or leads to carry the electrical impulse to the patient's heart. Pacemaker and implantable cardioverter defibrillator codes were made to describe the type of pacemaker or implantable cardioverter defibrillator implanted. Indications for pacing and implantable cardioverter defibrillator implantation were given by the American College of Cardiologists. Certain pacemakers have magnet-operated reed switches incorporated; however, magnet application can have serious adverse effects; hence, devices should be considered programmable unless known otherwise. When a device patient undergoes any procedure (with or without anesthesia, special precautions have to be observed including a focused history/physical examination, interrogation of pacemaker before and after the procedure, emergency drugs/temporary pacing and defibrillation, reprogramming of pacemaker and disabling certain pacemaker functions if required, monitoring of electrolyte and metabolic disturbance and avoiding certain drugs and equipments that can interfere with pacemaker function. If unanticipated device interactions are found, consider discontinuation of the procedure until the source of interference can be eliminated or managed and all corrective measures should be taken to ensure proper pacemaker function should be done. Post procedure, the cardiac rate and rhythm should be monitored continuously and emergency drugs and equipments should be kept ready and consultation with a cardiologist or a pacemaker-implantable cardioverter defibrillator service may be necessary.

  14. Interference of electronic apex locators with implantable cardioverter defibrillators

    NARCIS (Netherlands)

    Idzahi, K.; de Cock, C.C.; Shemesh, H.; Brand, H.S.

    2014-01-01

    Introduction The purpose of this in vitro study was to evaluate the potential electromagnetic interference of electronic apex locators (EALs) on implantable cardioverter defibrillators (ICDs). Methods Four different EALs were tested for their ability to interfere with the correct function of 3 diffe

  15. Phantom shocks in patients with implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Moons, Philip; Zwisler, Ann-Dorthe

    2013-01-01

    The aim of this trial was to assess a combined rehabilitation intervention including an exercise training component and a psycho-educational component in patients treated with implantable cardioverter defibrillator (ICD). The hypothesis was that the intervention would reduce the occurrence...

  16. Dental management of a patient fitted with subcutaneous Implantable Cardioverter Defibrillator device and concomitant warfarin treatment

    OpenAIRE

    Altaf Hussain Shah; Hesham Saleh Khalil; Mohammed Zaheer Kola

    2015-01-01

    Automated Implantable Cardioverter Defibrillators (AICD), simply known as an Implantable Cardioverter Defibrillator (ICD), has been used in patients for more than 30 years. An Implantable Cardioverter Defibrillator (ICD) is a small battery-powered electrical impulse generator that is implanted in patients who are at a risk of sudden cardiac death due to ventricular fibrillation, ventricular tachycardia or any such related event. Typically, patients with these types of occurrences are on antic...

  17. Impact of carvedilol and metoprolol on inappropriate implantable cardioverter-defibrillator therapy

    DEFF Research Database (Denmark)

    Ruwald, Martin H; Abu-Zeitone, Abeer; Jons, Christian;

    2013-01-01

    The goal of this study was to evaluate the effects of carvedilol and metoprolol on the endpoint of inappropriate implantable cardioverter-defibrillator therapy in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation With Cardiac Resynchronization Therapy) study.......The goal of this study was to evaluate the effects of carvedilol and metoprolol on the endpoint of inappropriate implantable cardioverter-defibrillator therapy in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation With Cardiac Resynchronization Therapy) study....

  18. Making post-mortem implantable cardioverter defibrillator explantation safe

    OpenAIRE

    Räder, Sune B.E.W.; Zeijlemaker, Volkert; Pehrson, Steen; Svendsen, Jesper H

    2009-01-01

    Aims The aim of this study is to investigate whether protection with rubber or plastic gloves during post-mortem explantation of an implantable cardioverter defibrillator (ICD) offers enough protection for the explanting operator during a worst-case scenario (i.e. ICD shock). Methods and results We investigated the insulating properties of rubber and plastic gloves (double layer) within the first 60 min exposure (mimicking the maximum time of an explantation procedure) to saline (simulating t...

  19. Lingular pneumonia obscured by implanted cardioverter-defibrillator: Lateral thinking.

    Science.gov (United States)

    Sewell, Laura; Harries, Ivan; Chandrasekaran, Barinathan

    2015-01-01

    A 56-year-old female with an implanted cardioverter-defibrillator was admitted with a short history suggestive of a diagnosis of pneumonia. An AP radiograph did not identify an area of consolidation. A subsequent lateral radiograph highlighted an extensive left-lingular-lobe consolidation that had been obscured by the cardiac device. This case highlights the fact that large devices can obscure significant pathology, and that lateral or cross-sectional imaging may be helpful in reaching a diagnosis.

  20. Lingular pneumonia obscured by implanted cardioverter-defibrillator: Lateral thinking

    OpenAIRE

    Laura Sewell, MD; Ivan Harries, MD; Barinathan Chandrasekaran, MD

    2015-01-01

    A 56-year-old female with an implanted cardioverter-defibrillator was admitted with a short history suggestive of a diagnosis of pneumonia. An AP radiograph did not identify an area of consolidation. A subsequent lateral radiograph highlighted an extensive left-lingular-lobe consolidation that had been obscured by the cardiac device. This case highlights the fact that large devices can obscure significant pathology, and that lateral or cross-sectional imaging may be helpful in reaching a diag...

  1. Behavioral interventions in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; Burg, Matthew M; Pedersen, Susanne S.

    2013-01-01

    The implantable cardioverter defibrillator (ICD) is the first-line treatment for primary and secondary prevention of sudden cardiac death. A subgroup of patients experience psychological distress postimplant, and no clear evidence base exists regarding how best to address patients' needs. The aim...... of this critical review is to provide an overview of behavioral interventions in ICD patients to date, and to delineate directions for future research using lessons learned from the ongoing RISTA and WEBCARE trials....

  2. Implantable cardioverter-defibrillator infection caused by Tsukamurella.

    Science.gov (United States)

    Almehmi, Ammar; Pfister, Alfred K; McCowan, Ronald; Matulis, Susie

    2004-01-01

    Human infections with Tsukamurella are very rare with only 13 reported cases in the literature. Certain conditions, such as immunosuppression, an indwelling foreign body, and postoperative wounds predispose humans to Tsukamurella infections. The rarity of Tsukamurella infection in humans makes its diagnosis and treatment very difficult. This article describes the first case of implantable cardioverter-defibrillator (ICD) infection related to Tsukamurella in the literature.

  3. Normativity under change: Older persons with implantable cardioverter defibrillator.

    Science.gov (United States)

    Svanholm, Jette Rolf; Nielsen, Jens Cosedis; Mortensen, Peter Thomas; Christensen, Charlotte Fuglesang; Birkelund, Regner

    2016-05-01

    In modern society, death has become 'forbidden' fed by the medical technology to conquer death. The technological paradigm is challenged by a social-liberal political ideology in postmodern Western societies. The question raised in this study was as follows: Which arguments, attitudes, values and paradoxes between modern and postmodern tendencies concerning treatment and care of older persons with an implantable cardioverter defibrillator appear in the literature? The aim of this study was to describe and interpret how the field of tension concerning older persons with an implantable cardioverter defibrillator - especially end-of-life issues - has been expressed in the literature throughout the last decade. Paul Ricoeur's reflexive interpretive approach was used to extract the meaningful content of the literature involving qualitative, quantitative and normative literature. Analysis and interpretation involved naive reading, structural analysis and critical interpretation. The investigation complied with the principles outlined in the Declaration of Helsinki. The unifying theme was 'Normativity under change'. The sub-themes were 'Death has become legitimate', 'The technological imperative is challenged' and 'Patients and healthcare professionals need to talk about end-of-life issues'. There seems to be a considerable distance between the normative approach of how practice ought to be and findings in empirical studies. Modern as well as postmodern attitudes and perceptions illustrate contradictory tendencies regarding deactivation of the implantable cardioverter defibrillator and replacement of the implantable cardioverter defibrillator in older persons nearing the end of life. The tendencies challenge each other in a struggle to gain position. On the other hand, they can also complement each other because professionalism and health professional expertise cannot stand alone when the patient's life is at stake but must be unfolded in an alliance with the patient who

  4. The occupational routine of patients implanted with cardioverter-defibrillator

    Directory of Open Access Journals (Sweden)

    Juliana Mannini

    2015-03-01

    Full Text Available Implantable cardioverter-defibrillators (ICD have become a reference as to the standard of care for patients with potentially lethal ventricular arrhythmias. The ICD treats the symptoms of the disease with no impact on its cause; however, the electrical discharge originating from the operating mechanism of this device has been the source of many studies addressing the quality of life of this population. The specific literature points to limitations of patients implanted with cardioverter-defibrillators regarding activities such as working and driving, but little has been discussed whether other areas of occupational performance are also limited. The purpose of this prospective exploratory research, which uses a case study design of quantitative nature, is to know the routine of patients implanted with cardioverter-defibrillator. Fifteen subjects with ICD participated in the study; they were outpatients in the arrhythmia sector of the ‘Clementino Fraga Filho’ University Hospital - HUCFF. The instruments for data collection included an initial interview, SF36 inventory, Role Checklist, and an open question. The results showed interference in the routine occupational performance and occupational roles evaluated, as well as in the fields of mental health and vitality, with greater focus on influences arising from the pathology than the mechanism of the device.

  5. Implantable cardioverter-defibrillator oversensing due to electric shock

    Directory of Open Access Journals (Sweden)

    Jurčević Ružica

    2010-01-01

    Full Text Available Introduction. We described the first case of oversensing due to electric shock in Serbia, in a 54-year-old man who had implantable cardioverter-defibrillator (ICD. Case Outline. In July 2002, the patient had acute anteroseptal myocardial infarction and ventricular fibrillation (VF which was terminated with six defibrillation shocks of 360 J. Coronary angiography revealed 30% stenosis of circumflex artery, the left anterior descending coronary artery was recanalized and the right coronary artery was without stenosis. Left ventricular ejection fraction was 20%. In December 2003, an electrophysiology study was performed and ventricular tachycardia (VT was induced and terminated with 200 J defibrillation shock. Single chamber ICD Medtronic Gem III VR was implanted in January 2004 and defibrillation threshold was 12 J. The patient was followed up during three years every three months and there were no VT/VF episodes and VT/VF therapies. In December 2007, the patient experienced electric shock through the fork while he was making barbecue on the electric grill. ICD recognized this event in VF zone (oversensing and delivered defibrillation shock of 18 J. The electrogram of the episode showed ventricular sensing - intrinsic sinus rhythm with electric shock potentials which were misidentified as VF. After charge time of 3.16 seconds, ICD delivered defibrillation shock and sinus rhythm was still present. Conclusion. Oversensing of ICD has different aetiology and the most common cause is supraventricular tachyarrhythmia.

  6. Spinal cord stimulation for refractory angina in a patient implanted with a cardioverter defibrillator.

    Science.gov (United States)

    Ferrero, Paolo; Grimaldi, Roberto; Massa, Riccardo; Chiribiri, Amedeo; De Luca, Anna; Castellano, Maddalena; Cardano, Paola; Trevi, Gian Paolo

    2007-01-01

    Spinal cord stimulation is currently used to treat refractory angina. Some concerns may arise about the possible interaction concerning the spinal cord stimulator in patients already implanted with a pacemaker or a cardioverter defibrillator. We are going to describe the successful implantation of a spinal cord stimulator in a patient previously implanted with a cardioverter defibrillator.

  7. Patient perceptions of implantable cardioverter-defibrillator deactivation discussions: A qualitative study

    Directory of Open Access Journals (Sweden)

    Jane MacIver

    2016-04-01

    Full Text Available Background: There is a class I recommendation for implantable cardioverter-defibrillator deactivation discussions to occur between physicians and heart failure patients. Few studies have reported the patient’s perspective on the timing of implantable cardioverter-defibrillator deactivation discussions. Aim: To determine patient awareness, preferences and timing of implantable cardioverter-defibrillator deactivation discussions. Design: Grounded theory was used to collect and analyze interview data from 25 heart failure patients with an implantable cardioverter-defibrillator. Setting and participants: Patients with an implantable cardioverter-defibrillator, from the Heart Function Clinic at University Health Network (Toronto, Canada. Results: The sample (n = 25 was predominately male (76% with an average age of 62 years. Patients identified three stages where they felt implantable cardioverter-defibrillator deactivation should be discussed: (1 prior to implantation, (2 with any significant deterioration but while they were of sound mind to engage in and communicate their preferences and (3 at end of life, where patients wished further review of their previously established preferences and decisions about implantable cardioverter-defibrillator deactivation. Most patients (n = 17, 68% said they would consider deactivation, six (24% were undecided and two (8% were adamant they would never turn it off. Conclusion: The patient preferences identified in this study support the need to include information on implantable cardioverter-defibrillator deactivation at implant, with change in clinical status and within broader discussions about end-of-life treatment preferences. Using this process to help patients determine and communicate their implantable cardioverter-defibrillator deactivation preferences may reduce the number of patients experiencing distressing implantable cardioverter-defibrillator shocks at end of life.

  8. Pre-implantation implantable cardioverter defibrillator concerns and Type D personality increase the risk of mortality in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van den Broek, Krista C; Erdman, Ruud A M;

    2010-01-01

    Little is known about the influence of psychological factors on prognosis in implantable cardioverter defibrillator (ICD) patients. We examined the influence of the distressed personality (Type D) and pre-implantation device concerns on short-term mortality in ICD patients.......Little is known about the influence of psychological factors on prognosis in implantable cardioverter defibrillator (ICD) patients. We examined the influence of the distressed personality (Type D) and pre-implantation device concerns on short-term mortality in ICD patients....

  9. Lingular pneumonia obscured by implanted cardioverter-defibrillator: Lateral thinking

    Directory of Open Access Journals (Sweden)

    Laura Sewell, MD

    2015-01-01

    Full Text Available A 56-year-old female with an implanted cardioverter-defibrillator was admitted with a short history suggestive of a diagnosis of pneumonia. An AP radiograph did not identify an area of consolidation. A subsequent lateral radiograph highlighted an extensive left-lingular-lobe consolidation that had been obscured by the cardiac device. This case highlights the fact that large devices can obscure significant pathology, and that lateral or cross-sectional imaging may be helpful in reaching a diagnosis.

  10. Making post-mortem implantable cardioverter defibrillator explantation safe

    DEFF Research Database (Denmark)

    Räder, Sune B E W; Zeijlemaker, Volkert; Pehrson, Steen;

    2009-01-01

    AIMS: The aim of this study is to investigate whether protection with rubber or plastic gloves during post-mortem explantation of an implantable cardioverter defibrillator (ICD) offers enough protection for the explanting operator during a worst-case scenario (i.e. ICD shock). METHODS AND RESULTS...... that the resting voltage over the operating person would not exceed 50 V. CONCLUSION: The use of intact medical gloves made of latex, neoprene, or plastic eliminates the potential electrical risk during explantation of an ICD. Two gloves on each hand offer sufficient protection. We will recommend the use...

  11. Magnets and implantable cardioverter defibrillators: What′s the problem?

    Directory of Open Access Journals (Sweden)

    Yiliam F Rodriguez-Blanco

    2013-01-01

    Full Text Available A growing number of surgical patients present to the operating room with implantable cardioverter defibrillators (ICD. Peri-operative care of these patients dictates that ICD function be suspended for many surgical procedures to avoid inappropriate, and possibly harmful, ICD therapy triggered by electromagnetic interference (EMI. An alternative to reprogramming the ICD is the use of a magnet to temporarily suspend its function. However, this approach is not without complications. We report a case where magnet use failed to inhibit ICD sensing of EMI, and a shock was delivered to the patient. Measures to decrease EMI, controversies regarding magnet use, and expert recommendations are discussed.

  12. Magnets and implantable cardioverter defibrillators: what's the problem?

    Science.gov (United States)

    Rodriguez-Blanco, Yiliam F; Souki, Fouad; Tamayo, Evelyn; Candiotti, Keith

    2013-01-01

    A growing number of surgical patients present to the operating room with implantable cardioverter defibrillators (ICD). Peri-operative care of these patients dictates that ICD function be suspended for many surgical procedures to avoid inappropriate, and possibly harmful, ICD therapy triggered by electromagnetic interference (EMI). An alternative to reprogramming the ICD is the use of a magnet to temporarily suspend its function. However, this approach is not without complications. We report a case where magnet use failed to inhibit ICD sensing of EMI, and a shock was delivered to the patient. Measures to decrease EMI, controversies regarding magnet use, and expert recommendations are discussed.

  13. Somatosensory amplification mediates sex differences in psychological distress among cardioverter-defibrillator patients

    DEFF Research Database (Denmark)

    Versteeg, Henneke; Baumert, Jens; Kolb, Christof

    2010-01-01

    The present study examined whether female patients with an implantable cardioverter defibrillator (ICD) report more psychological distress than male patients, and whether somatosensory amplification mediates this relationship. Design: Consecutive ICD patients (N = 241; 33% women) participating in...

  14. Coping with Trauma and Stressful Events As a Patient with an Implantable Cardioverter-Defibrillator

    Science.gov (United States)

    ... Patient Page Coping With Trauma and Stressful Events as a Patient With an Implantable Cardioverter-Defibrillator Jessica Ford , ... plan for developing effective coping responses. Is There a Difference Between a Stressful Event and a Traumatic ...

  15. Prognostic importance of distressed (Type D) personality and shocks in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Denollet, Johan; Tekle, Fetene B; Pedersen, Susanne S.;

    2013-01-01

    Clinical trials have shown the benefit of implantable cardioverter defibrillator (ICD) treatment. In this study, we examined the importance of chronic psychological distress and device shocks among ICD patients seen in clinical practice....

  16. Anxiety and risk of ventricular arrhythmias or mortality in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; Pedersen, Susanne S.; van den Broek, Krista C;

    2013-01-01

    A subgroup of patients with an implantable cardioverter defibrillator (ICD) experiences anxiety after device implantation. The purpose of the present study was to evaluate whether anxiety is predictive of ventricular arrhythmias and all-cause mortality 1 year post ICD implantation.......A subgroup of patients with an implantable cardioverter defibrillator (ICD) experiences anxiety after device implantation. The purpose of the present study was to evaluate whether anxiety is predictive of ventricular arrhythmias and all-cause mortality 1 year post ICD implantation....

  17. Attrition and Adherence in a Web-Based Distress Management Program for Implantable Cardioverter Defibrillator Patients (WEBCARE): Randomized Controlled Trial

    DEFF Research Database (Denmark)

    Habibovic, M.; Cuijpers, P.; Alings, M.;

    2014-01-01

    Background: WEB-Based Distress Management Program for Implantable CARdioverter defibrillator Patients (WEBCARE) is a Web-based randomized controlled trial, designed to improve psychological well-being in patients with an implantable cardioverter defibrillator (ICD). As in other Web-based trials, ...

  18. Clinical efficacy and safety of an implantable cardioverter-defibrillator lead with a floating atrial sensing dipole

    DEFF Research Database (Denmark)

    Safak, Erdal; Schmitz, Dietmar; Konorza, Thomas;

    2013-01-01

    The concept of a single-lead implantable cardioverter-defibrillator (ICD), with a floating dipole, has been proven safe and functional.......The concept of a single-lead implantable cardioverter-defibrillator (ICD), with a floating dipole, has been proven safe and functional....

  19. The National Survey of Cardiac Pacemakers and Cardioverter Defibrillators

    Directory of Open Access Journals (Sweden)

    Gholamrerza Shafieian

    2006-07-01

    Full Text Available Background: Permanent pacemakers provide effective relief of symptoms and are life-saving in patients with symptomatic heart block. Implantable cardioverter defibrillators (ICD are also increasingly recognized as life-saving tools in various groups of patients with malignant ventricular tachyarrhythmias. Methods: As part of the “world survey on pacemaker and ICD implantations”, a survey of all device implantations in Iran during the year 2001 was performed. Data was collected and cross-checked through three sources i.e. direct contact with implanting physicians, pacemaker companies and the governmental pacemaker distributing body.Results: During the year studied, 1635 patients received permanent pacemakers. 88% were new implants at an estimated rate of 24 per million population. The mean age of patients was 65 years and 56.2% were male. 40 cardiologists and 19 surgeons implanted the pacemakers at 27 centers throughout the country. Complete heart block was consistently the most common indication at all centers (mean 56.1%, sick sinus syndrome being the next most common one (mean 20.8%. 69% of the pacemakers were single chamber pacemakers. Transvenous insertion of bipolar steroid-eluting passive fixation leads was the predominant practice at most centers. A total of 60 ICDs were implanted at 7 centers by 9 cardiologists. 45% of ICD implants were dual chamber devices.Conclusion: The survey is the only one available right now and provides useful information about the prevailing pacemaker and defibrillator implantation practice in Iran. Future surveys would be facilitated if a standardized implant registry such as that used in Europe were established in this country.

  20. Antitachycardia pacing programming in implantable cardioverter defibrillator: A systematic review.

    Science.gov (United States)

    De Maria, Elia; Giacopelli, Daniele; Borghi, Ambra; Modonesi, Letizia; Cappelli, Stefano

    2017-05-26

    Implantable cardioverter defibrillator (ICD) programming involves several parameters. In recent years antitachycardia pacing (ATP) has gained an increasing importance in the treatment of ventricular arrhythmias, whether slow or fast. It reduces the number of unnecessary and inappropriate shocks and improves both patient's quality of life and device longevity. There is no clear indication regarding the type of ATP to be used, except for the treatment of fast ventricular tachycardias (188 bpm-250 bpm) where it has been shown a greater efficacy and safety of burst compared to ramp; 8 impulses in each sequence of ATP appears to be the best programming option in this setting. Beyond ATP use, excellent clinical results were obtained with programming standardization following these principles: extended detection time in ventricular fibrillation (VF) zone; supraventricular discrimination criteria up to 200 bpm; first shock in VF zone at the maximum energy in order to reduce the risk of multiple shocks. The MADIT-RIT trial and some observational registries have also recently demonstrated that programming with a widespread use of ATP, higher cut-off rates or delayed intervention reduces the number of inappropriate and unnecessary therapies and improves the survival of patients during mid-term follow-up.

  1. Sensing and detection in Medtronic implantable cardioverter defibrillators.

    Science.gov (United States)

    Brown, Mark L; Swerdlow, Charles D

    2016-09-01

    Ensuring sensing and detection of ventricular tachycardia (VT) and ventricular fibrillation (VF) was a prerequisite for the clinical trials that established the survival benefit of implantable cardioverter defibrillators (ICDs). However, for decades, a high incidence of unnecessary shocks limited patients' and physicians' acceptance of ICD therapy. Oversensing, misclassification of supraventricular tachycardia (SVT) as VT, and self-terminating VT accounted for the vast majority of unnecessary shocks. Medtronic ICDs utilize sensitive baseline settings with minimal blanking periods to ensure accurate sensing of VF, VT, and SVT electrograms. Programmable algorithms reject oversensing caused by far-field R waves, T waves, and non-physiologic signals caused by lead failure. A robust hierarchy of SVT-VT discriminators minimize misclassification of SVT as VT. These features, combined with evidence-based programming, have reduced the 1‑year inappropriate shock rate to 1.5 % for dual-/triple-chamber ICDs and to 2.5 % for single-chamber ICDs.

  2. Battery longevity in cardiac resynchronization therapy implantable cardioverter defibrillators.

    Science.gov (United States)

    Alam, Mian Bilal; Munir, Muhammad Bilal; Rattan, Rohit; Flanigan, Susan; Adelstein, Evan; Jain, Sandeep; Saba, Samir

    2014-02-01

    Cardiac resynchronization therapy (CRT) implantable cardioverter defibrillators (ICDs) deliver high burden ventricular pacing to heart failure patients, which has a significant effect on battery longevity. The aim of this study was to investigate whether battery longevity is comparable for CRT-ICDs from different manufacturers in a contemporary cohort of patients. All the CRT-ICDs implanted at our institution from 1 January 2008 to 31 December 2010 were included in this analysis. Baseline demographic and clinical data were collected on all patients using the electronic medical record. Detailed device information was collected on all patients from scanned device printouts obtained during routine follow-up. The primary endpoint was device replacement for battery reaching the elective replacement indicator (ERI). A total of 646 patients (age 69 ± 13 years), implanted with CRT-ICDs (Boston Scientific 173, Medtronic 416, and St Jude Medical 57) were included in this analysis. During 2.7 ± 1.5 years follow-up, 113 (17%) devices had reached ERI (Boston scientific 4%, Medtronic 25%, and St Jude Medical 7%, P battery was significantly worse for Medtronic devices compared with devices from other manufacturers (94% for Boston scientific, 67% for Medtronic, and 92% for St Jude Medical, P battery longevity by manufacturer was independent of pacing burden, lead parameters, and burden of ICD therapy. There are significant discrepancies in CRT-ICD battery longevity by manufacturer. These data have important implications on clinical practice and patient outcomes.

  3. [Primary prevention of sudden cardiac death through a wearable cardioverter-defibrillator].

    Science.gov (United States)

    Gabrielli, Domenico; Benvenuto, Manuela; Baroni, Matteo; Oliva, Fabrizio; Capucci, Alessandro

    2015-01-01

    Nowadays, the implantable cardioverter-defibrillator is the gold standard for the prevention of sudden cardiac death due to tachyarrhythmias. However, its use is not free from short and long-term risks. In the last years, the wearable cardioverter-defibrillator (WCD) has become a widespread option for patients who need a safe and reversible protection against ventricular tachyarrhythmias. Notwithstanding this, its everyday application is restricted by several limitations, including the risk of inappropriate shocks, the device size and the need for strict compliance of both patients and caregivers. In this review, we report the most relevant literature data on WCD usage along with the main fields of applications and future perspectives.

  4. Successful intermuscular implantation of subcutaneous implantable cardioverter defibrillator in a Japanese patient with pectus excavatum.

    Science.gov (United States)

    Kondo, Yusuke; Ueda, Marehiko; Winter, Joachim; Nakano, Miyo; Nakano, Masahiro; Ishimura, Masayuki; Miyazawa, Kazuo; Tateno, Kaoru; Kobayashi, Yoshio

    2017-02-01

    The entirely subcutaneous implantable cardioverter-defibrillator (ICD) system was developed to provide a life-saving defibrillation therapy that does not affect the heart and vasculature. The subcutaneous ICD is preferred over the transvenous ICD for patients with a history of recurrent infection presenting major life-threatening rhythms. In this case report, we describe the first successful intermuscular implantation of a completely subcutaneous ICD in a Japanese patient with pectus excavatum. There were no associated complications with the device implantation or lead positioning. Further, the defibrillation threshold testing did not pose any problem with the abnormal anatomy of the patient.

  5. Outcome of implantable cardioverter defibrillators in adults with congenital heart disease : a multi-centre study

    NARCIS (Netherlands)

    Yap, Sing-Chien; Roos-Hesselink, Jolien W.; Hoendermis, Elke S.; Budts, Werner; Vliegen, Hubert W.; Mulder, Barbara J. M.; van Dijk, Arie P. J.; Schalij, Martin J.; Drenthen, Willem

    2007-01-01

    Aims To investigate outcome and complications of implantable cardioverter defibrillators (ICDs) in adults with congenital heart disease (CHD) and to identify predictors of (in-) appropriate shocks. Methods and results Sixty-four CHD patients >= 18 years at first ICD implantation [63% tetralogy of Fa

  6. Emotional distress in partners of patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Van Den Broek, Krista C; Habibović, Mirela; Pedersen, Susanne S.

    2010-01-01

    Both patients with an implantable cardioverter defibrillator (ICD) and their partners face challenges when adapting to the ICD. Distress is a burden on its own for partners but may also affect well being and health of patients. This review provides a systematic overview of the literature on psych...

  7. Psychometric analysis of the Patient Health Questionnaire in Danish patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Mathiasen, Kim; Christensen, Karl Bang

    2016-01-01

    OBJECTIVE: To assess the psychometric properties of the Patient Health Questionnaire (PHQ-9), a measure of depressive symptoms, in a large Danish national cohort of patients with heart disease, implanted with an implantable cardioverter defibrillator (ICD), using item response theory. METHODS...

  8. Effects of an alert system on implantable cardioverter defibrillator-related anxiety

    DEFF Research Database (Denmark)

    Duru, Firat; Dorian, Paul; Favale, Stefano

    2010-01-01

    Implantable cardioverter defibrillators (ICD) can prevent sudden cardiac death by delivering high-energy shocks in patients at risk of life-threatening ventricular tachyarrhythmias. Patients may be anxious about receiving inappropriate shocks in case of device or lead system malfunction, or about...

  9. Non-pharmacological treatment of heart failure: Implantable cardioverter defibrillator (ICD) and cardiac resynchronisation therapy

    NARCIS (Netherlands)

    Van Gelder, I.C.; Smit, M.D.; Nieuwland, W; Van Veldhuisen, D.J.

    2006-01-01

    The non-pharmacological therapy of heart failure, in particular an implantable cardioverter defibrillator (ICD) and cardiac resynchronisation therapy or biventricular stimulation, improves symptoms and survival in patients with heart failure. - An ICD is indicated in many patients with heart failure

  10. Monitoring device acceptance in implantable cardioverter defibrillator patients using the Florida Patient Acceptance Survey

    DEFF Research Database (Denmark)

    Versteeg, Henneke; Starrenburg, Annemieke; Denollet, Johan

    2012-01-01

    Patient device acceptance might be essential in identifying patients at risk for adverse patient-reported outcomes following implantation of an implantable cardioverter defibrillator (ICD). We examined the validity and reliability of the Florida Patient Acceptance Scale (FPAS) and identified corr...

  11. Gender disparities in anxiety and quality of life in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; van den Broek, Krista C; Theuns, Dominic A M J

    2011-01-01

    A paucity of studies in implantable cardioverter-defibrillator (ICD) patients has examined gender disparities in patient-reported outcomes, such as anxiety and quality of life (QoL). We investigated (i) gender disparities in anxiety and QoL and (ii) the magnitude of the effect of gender vs. New...

  12. Experiences of patients with implantable cardioverter defibrillator in Turkey: A qualitative study

    Directory of Open Access Journals (Sweden)

    Özgür Aslan

    2012-01-01

    Full Text Available Background. There has been an increase in the number of patients with implantable cardioverter defibrillator (ICD. It isimportant to understand ICD patients’ experiences with it.Aim. The aim of this study was to describe experiences of patients with implantable cardioverter defibrillator (ICD.Methodology. A qualitative approach was used. Focus group interviews were used to obtain data from 19 patients whowere implanted cardioverter defibrillator at two centers in Izmir, Turkey. The patients were assigned into four groups. Thedata was analyzed using qualitative content analysis.Results. The analysis revealed six main themes: activities of daily living, social life, familial relationships, emotionalchanges, implantable cardioverter defibrillator shocks and experiences with receiving information and counselling fromhealth care providers.Conclusions. It can be concluded that patients with ICD experience physical and psychological problems and are not offeredthe education they need. To reduce the fears of the patients and their families and to prepare them for possible life stylechanges, comprehensive training programs that start in the pre-implantation period and continue into the post-implantationperiod should be organized.

  13. Undertreatment of anxiety and depression in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Kupper, Nina; Theuns, Dominic A M J

    2012-01-01

    Twenty-five to 33% of patients with an implantable cardioverter-defibrillator (ICD) experience anxiety and depression, but it is not known whether their symptoms are adequately treated. We investigated (a) whether patients with clinically relevant symptoms of distress received appropriate treatment...

  14. Increased anxiety in partners of patients with a cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; VAN DEN Berg, Martha; Erdman, Ruud A M

    2009-01-01

    The partner of the implantable cardioverter-defibrillator (ICD) patient serves as an important source of support for the patient, which may be hampered if the partner experiences increased distress. We examined (1) potential differences in anxiety and depressive symptoms in ICD patients compared...

  15. SUDDEN CARDIAC DEATH AND THE USE OF IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS IN PEDIATRIC-PATIENTS

    NARCIS (Netherlands)

    SILKA, MJ; KRON, J; DUNNIGAN, A; DICK, M; BINKBOELKENS, M; ERICKSON, CC; JEDEIKIN, R; WETZEL, GT; VANHARE, GF; CAMPBELL, R; WALSH, E; SAUL, JP; SCHAFFER, MS; KARPAWICH, P; VOGEL, RL; BENSON, DW; DEAL, B; SCAGLIOTTI, D; STERBA, R; HORDOF, AJ; KRONGRAD, E; KANTER, RJ; EPSTEIN, M; COHEN, M; BEDER, S; HAMILTON, R; FOURNIER, A; HUBBARD, J; CHRISTIANSEN, JL; JENNINGS, J; VILLAFANE, J; PORTER, CBJ; CASE, C; GILLETTE, PC; BELAND, M; KUGLER, JD; OCONNOR, BK; ALLENDER, H; HERNDON, SP; SMITH, RT; BURTON, D; KURER, CC; BYRUM, C; GUAM, WE; FRIEDMAN, R; PERRY, JC; SCOTT, W; MEHTA, AV; PICKHOFF, AS; FISH, F; YEAGER, S; KAWABORI, [No Value; TRIPPLE, M; ROSENFELD, LE

    Background. During the past decade. the implantable cardioverter-defibrillator (ICD) has emerged as the primary therapeutic option for survivors of sudden cardiac death (SCD). Investigation of the clinical efficacy of these devices has primarily assessed outcome in adults with coronary artery

  16. Fuzzy logic-based diagnostic algorithm for implantable cardioverter defibrillators.

    Science.gov (United States)

    Bárdossy, András; Blinowska, Aleksandra; Kuzmicz, Wieslaw; Ollitrault, Jacky; Lewandowski, Michał; Przybylski, Andrzej; Jaworski, Zbigniew

    2014-02-01

    The paper presents a diagnostic algorithm for classifying cardiac tachyarrhythmias for implantable cardioverter defibrillators (ICDs). The main aim was to develop an algorithm that could reduce the rate of occurrence of inappropriate therapies, which are often observed in existing ICDs. To achieve low energy consumption, which is a critical factor for implantable medical devices, very low computational complexity of the algorithm was crucial. The study describes and validates such an algorithm and estimates its clinical value. The algorithm was based on the heart rate variability (HRV) analysis. The input data for our algorithm were: RR-interval (I), as extracted from raw intracardiac electrogram (EGM), and in addition two other features of HRV called here onset (ONS) and instability (INST). 6 diagnostic categories were considered: ventricular fibrillation (VF), ventricular tachycardia (VT), sinus tachycardia (ST), detection artifacts and irregularities (including extrasystoles) (DAI), atrial tachyarrhythmias (ATF) and no tachycardia (i.e. normal sinus rhythm) (NT). The initial set of fuzzy rules based on the distributions of I, ONS and INST in the 6 categories was optimized by means of a software tool for automatic rule assessment using simulated annealing. A training data set with 74 EGM recordings was used during optimization, and the algorithm was validated with a validation data set with 58 EGM recordings. Real life recordings stored in defibrillator memories were used. Additionally the algorithm was tested on 2 sets of recordings from the PhysioBank databases: MIT-BIH Arrhythmia Database and MIT-BIH Supraventricular Arrhythmia Database. A custom CMOS integrated circuit implementing the diagnostic algorithm was designed in order to estimate the power consumption. A dedicated Web site, which provides public online access to the algorithm, has been created and is available for testing it. The total number of events in our training and validation sets was 132. In

  17. Monitoring treatment expectations in patients with an implantable cardioverter-defibrillator using the EXPECT-ICD scale

    NARCIS (Netherlands)

    Habibovic, M.; Pedersen, S.S.; van den Broek, K.C.; Denollet, J.

    2014-01-01

    Aims Patient treatment expectations may affect cardiac outcomes; however, till date, no validated instruments have been developed to monitor treatment expectations in patients with an implantable cardioverter-defibrillator (ICD). This study evaluates the predictive value of the newly developed

  18. Cost-Effectiveness of Adding Cardiac Resynchronization Therapy to an Implantable Cardioverter-Defibrillator Among Patients With Mild Heart Failure

    DEFF Research Database (Denmark)

    Woo, Christopher Y; Strandberg, Erika J; Schmiegelow, Michelle D;

    2015-01-01

    BACKGROUND: Cardiac resynchronization therapy (CRT) reduces mortality and heart failure hospitalizations in patients with mild heart failure. OBJECTIVE: To estimate the cost-effectiveness of adding CRT to an implantable cardioverter-defibrillator (CRT-D) compared with implantable cardioverter......-defibrillator (ICD) alone among patients with left ventricular systolic dysfunction, prolonged intraventricular conduction, and mild heart failure. DESIGN: Markov decision model. DATA SOURCES: Clinical trials, clinical registries, claims data from Centers for Medicare & Medicaid Services, and Centers for Disease...

  19. Implantable cardioverter defibrillator and survival after out-of-hospital cardiac arrest due to acute myocardial infarction in Denmark in the years 2001-2012, a nationwide study

    DEFF Research Database (Denmark)

    Winther-Jensen, Matilde; Kjaergaard, Jesper; Lassen, Jens F

    2017-01-01

    AIM: The purpose of this study was to describe the implantation of implantable cardioverter defibrillator after out-of-hospital cardiac arrest caused by myocardial infarction in Denmark 2001-2012 and subsequent survival. METHODS: The Danish Cardiac Arrest Registry was used to identify patients ⩾18...... years surviving to discharge without prior implantable cardioverter defibrillator. Information on cardioverter defibrillator implantation was obtained from the National Patient Registry. RESULTS: We identified 974 myocardial infarction-out-of-hospital cardiac arrest patients surviving to hospital...... discharge, 130 of these patients (13%) had a cardioverter defibrillator implanted early (⩽40 days post-out-of-hospital cardiac arrest), 58 patients (6%) had late implantable cardioverter defibrillator (41-365 days post-out-of-hospital cardiac arrest). Odds of implantable cardioverter defibrillator...

  20. Spinal cord stimulation for refractory angina in patients implanted with cardioverter defibrillators: five case reports

    DEFF Research Database (Denmark)

    Enggaard, Thomas P; Andersen, Claus; Scherer, Christian

    2010-01-01

    successful long-term treatment with SCS in five patients implanted with cardioverter defibrillators. The combined treatments with ICD and thoracic epidural electrical stimulation were used in five patients with refractory angina pectoris. During the procedure of the implantation, testing with the maximal...... tolerable level of stimulation was carried out to exclude inference with the ICD. The following treatment with SCS has in all cases been successful, with significant pain relief and improved quality of life. There were no incidences of inappropriate defibrillator shocks. Spinal cord stimulation...

  1. Inappropriate implantable cardioverter defibrillator shock from a transcutaneous muscle stimulation device therapy.

    Science.gov (United States)

    Siu, Chung-Wah; Tse, Hung-Fat; Lau, Chu-Pak

    2005-06-01

    Inappropriate shock from implantable cardioverter defibrillator (ICD) may result from external electromagnetic interference (EMI), especially for unipolar ventricle sensing. Previous case reports and small in-vitro safety study suggested that endocardial bipolar lead system may be immune from EMI resulting from transcutaneous electrical neuromuscle stimulation (TENS) therapy. This report presents an unusual case of inappropriate discharge in a patient with ICD of endocardial bipolar lead system, receiving TENS from a commercially available device.

  2. The dilemma of implantable cardioverter-defibrillator therapy in the geriatric population

    Institute of Scientific and Technical Information of China (English)

    Diana Revenco; James P Morgan; Lana Tsao

    2011-01-01

    Current guidelines for implantable cardioverter-defibrillator(ICD)therapy in heart failure patients were established by multiple device trials;however,very few geriatric patients(patients≥65 years old)were included in these studies.This article explores the controversies of ICD implantation in the geriatric population,management of delivered ICD therapy in this age group,and the end of life care in patients with ICD.

  3. Psychological effects of implantable cardioverter defibrillator shocks. A review of study methods

    OpenAIRE

    Manzoni, Gian Mauro; Castelnuovo, Gianluca; Compare, Angelo; Pagnini, Francesco; Essebag, Vidal; Proietti, Riccardo

    2015-01-01

    Background: The implantable cardioverter defibrillator (ICD) saves lives but clinical experience suggests that it may have detrimental effects on mental health. The ICD shock has been largely blamed as the main offender but empirical evidence is not consistent, perhaps because of methodological differences across studies. Objective: To appraise methodologies of studies that assessed the psychological effects of ICD shock and explore associations between methods and results. Data Sources...

  4. Conservative Management of Skin Fistula Occurring After Internal Cardioverter Defibrillator Replacement

    OpenAIRE

    2012-01-01

    Skin fistula occurring after cardiac electronic device implantation is frequently related to pocket infection and this condition typically requires removal of device and lead(s). We report on a case of skin fistula occurring 3 weeks after internal cardioverter defibrillator replacement. Conservative management consisted of local care along with oral antibiotics without removal of device; this strategy resulted in complete healing and closure of the fistula.

  5. Silicone Breast Implant and Automatic Implantable Cardioverter Defibrillator: Can They Coexist? A Case Report

    OpenAIRE

    Or, Friedman; Arik, Zaretski

    2016-01-01

    Summary: We present a case of a silicone breast implant rupture after insertion of an automatic implantable cardioverter defibrillator (AICD). A 51-year-old woman presented to our plastic surgery clinic to exchange her silicone breast implants. The patient underwent cosmetic mastopexy and breast augmentation in 2008. Because of recurrent myocardial infarctions and chronic heart failure, she underwent an insertion of an AICD in 2014 in which the left breast implant was hit. In this report, we ...

  6. Psychological effects of implantable cardioverter defibrillator shocks. A review of study methods.

    OpenAIRE

    Gian Mauro eManzoni; Gianluca eCastelnuovo; Angelo eCompare; Francesco ePagnini; Vidal eEssebag; Riccardo eProietti

    2015-01-01

    BackgroundThe implantable cardioverter defibrillator (ICD) saves lives but clinical experience suggests that it may have detrimental effects on mental health. The ICD shock has been largely blamed as the main offender but empirical evidence is not consistent, perhaps because of methodological differences across studies. ObjectiveTo appraise methodologies of studies that assessed the psychological effects of ICD shock and explore associations between methods and results. Data Sources A compreh...

  7. Dental management of a patient fitted with subcutaneous Implantable Cardioverter Defibrillator device and concomitant warfarin treatment.

    Science.gov (United States)

    Shah, Altaf Hussain; Khalil, Hesham Saleh; Kola, Mohammed Zaheer

    2015-07-01

    Automated Implantable Cardioverter Defibrillators (AICD), simply known as an Implantable Cardioverter Defibrillator (ICD), has been used in patients for more than 30 years. An Implantable Cardioverter Defibrillator (ICD) is a small battery-powered electrical impulse generator that is implanted in patients who are at a risk of sudden cardiac death due to ventricular fibrillation, ventricular tachycardia or any such related event. Typically, patients with these types of occurrences are on anticoagulant therapy. The desired International Normalized Ratio (INR) for these patients is in the range of 2-3 to prevent any subsequent cardiac event. These patients possess a challenge to the dentist in many ways, especially during oral surgical procedures, and these challenges include risk of sudden death, control of post-operative bleeding and pain. This article presents the dental management of a 60 year-old person with an ICD and concomitant anticoagulant therapy. The patient was on multiple medications and was treated for a grossly neglected mouth with multiple carious root stumps. This case report outlines the important issues in managing patients fitted with an ICD device and at a risk of sudden cardiac death.

  8. Athletic participation in the young patient with an implantable cardioverter-defibrillator.

    Science.gov (United States)

    Lampert, Rachel; Law, Ian

    2017-01-01

    The decision of whether to allow a young patient with an implantable cardioverter-defibrillator to continue to participate in sports is complex and multi-factorial. The positive physical and psychosocial impact of sports participation must be weighed against the potential adverse events associated with implantable cardioverter-defibrillators. Arrhythmias appear to be more prevalent in athletes and occur more frequently during physical activity or competition/practice, but there is growing evidence that device therapy is effective in athletes across a wide range of competitive sports. Failure of a device to convert a life-threatening arrhythmia, major injury from a shock, and increased lead failure have thus far not been reported in the prospective Implantable Cardioverter-Defibrillator Sports Registry, but follow-up remains relatively short. Thoughtful consideration of disease state, arrhythmia risk, and the potential dangers of device therapy during the desired sports is imperative before allowing participation. Frank discussion with children and families regarding the possibility of shocks during sports, as well as at other times, is imperative. Ongoing and future studies will help guide these decisions.

  9. Patient-tailored implantable cardioverter defibrillator testing using the upper limit of vulnerability: the TULIP protocol.

    Science.gov (United States)

    Lemke, Bernd; Lawo, Thomas; Zarse, Markus; Lubinski, Andrzej; Kreutzer, Ulrich; Mueller, Johannes; Schuchert, Andreas; Mitzenheim, Sabine; Danilovic, Dejan; Deneke, Thomas

    2008-08-01

    We evaluated the feasibility of the TULIP (Threshold test using Upper Limit during ImPlantation) protocol, which was designed to provide a confirmed, low defibrillation energy value during implantable cardioverter defibrillator (ICD) implantation with only two induced ventricular fibrillation (VF) episodes. Ninety-eight patients (62 +/- 12 years, 86 male) from 13 clinical centres underwent an active can ICD implantation. A single coupling interval derived from electrocardiogram lead II during ventricular pacing was used for VF induction shocks at 13, 11, 9, and 6 J in a step-down manner until the upper limit of VF induction (ULVI) was determined. If ULVI >or=9 J, a defibrillation energy of ULVI + 4 J was tested. For ULVI <9 J, the defibrillation test energy was 9 J. In 79/98 patients (80.6%), two induced VF episodes were sufficient to obtain confirmed defibrillation energy of 11.1 +/- 3.3 J. The mean strength of the successful VF induction shock was 6.8 +/- 4.3 J, the coupling interval was 303 +/- 35 ms, and the number of delivered induction shocks until the first VF induction was 3.9 +/- 1.6. TULIP is a safe and simple device testing procedure allowing the determination of confirmed, low defibrillation energy in most patients with two VF episodes induced at a single coupling interval.

  10. The Medtronic Sprint Fidelis Lead Advisory Notification has no adverse impact on patient reported outcomes in Danish implantable cardioverter defibrillator patients

    DEFF Research Database (Denmark)

    Pedersen, Susanne Møller; Versteeg, Henneke; Nielsen, Jens C.

    The Medtronic Sprint Fidelis Lead Advisory Notification has no adverse impact on patient reported outcomes in Danish implantable cardioverter defibrillator patients.......The Medtronic Sprint Fidelis Lead Advisory Notification has no adverse impact on patient reported outcomes in Danish implantable cardioverter defibrillator patients....

  11. The Medtronic Sprint Fidelis Lead Advisory Notification Has No Adverse Impact on Patient Reported Outcomes in Danish Implantable Cardioverter Defibrillator Patients

    DEFF Research Database (Denmark)

    Pedersen, Susanne Møller; Versteeg, Henneke; Nielsen, Jens C.

    The Medtronic Sprint Fidelis Lead Advisory Notification Has No Adverse Impact on Patient Reported Outcomes in Danish Implantable Cardioverter Defibrillator Patients.......The Medtronic Sprint Fidelis Lead Advisory Notification Has No Adverse Impact on Patient Reported Outcomes in Danish Implantable Cardioverter Defibrillator Patients....

  12. Beam Profile Disturbances from Implantable Pacemakers or Implantable Cardioverter-Defibrillator Interactions

    Energy Technology Data Exchange (ETDEWEB)

    Gossman, Michael S., E-mail: mgossman@tsrcc.com [Tri-State Regional Cancer Center, Medical Physics Section, Ashland, KY (United States); Comprehensive Heart and Vascular Associates, Heart and Vascular Center, Ashland, KY (United States); Medtronic, Inc., External Research Program, Mounds View, MN (United States); Nagra, Bipinpreet; Graves-Calhoun, Alison; Wilkinson, Jeffrey [Tri-State Regional Cancer Center, Medical Physics Section, Ashland, KY (United States); Comprehensive Heart and Vascular Associates, Heart and Vascular Center, Ashland, KY (United States); Medtronic, Inc., External Research Program, Mounds View, MN (United States)

    2011-01-01

    The medical community is advocating for progressive improvement in the design of implantable cardioverter-defibrillators and implantable pacemakers to accommodate elevations in dose limitation criteria. With advancement already made for magnetic resonance imaging compatibility in some, a greater need is present to inform the radiation oncologist and medical physicist regarding treatment planning beam profile changes when such devices are in the field of a therapeutic radiation beam. Treatment plan modeling was conducted to simulate effects induced by Medtronic, Inc.-manufactured devices on therapeutic radiation beams. As a continuation of grant-supported research, we show that radial and transverse open beam profiles of a medical accelerator were altered when compared with profiles resulting when implantable pacemakers and cardioverter-defibrillators are placed directly in the beam. Results are markedly different between the 2 devices in the axial plane and the sagittal planes. Vast differences are also presented for the therapeutic beams at 6-MV and 18-MV x-ray energies. Maximum changes in percentage depth dose are observed for the implantable cardioverter-defibrillator as 9.3% at 6 MV and 10.1% at 18 MV, with worst distance to agreement of isodose lines at 2.3 cm and 1.3 cm, respectively. For the implantable pacemaker, the maximum changes in percentage depth dose were observed as 10.7% at 6 MV and 6.9% at 18 MV, with worst distance to agreement of isodose lines at 2.5 cm and 1.9 cm, respectively. No differences were discernible for the defibrillation leads and the pacing lead.

  13. The use of guideline recommended beta-blocker therapy in primary prevention implantable cardioverter defibrillator patients

    DEFF Research Database (Denmark)

    Ruwald, Anne-Christine; Gislason, Gunnar Hilmar; Vinther, Michael

    2017-01-01

    Aims: We aimed to examine the use of guideline recommended beta-blocker therapy prior to and after primary prevention implantable cardioverter defibrillator (ICD) implantation in a 'real-life' setting. Methods and results: From the Danish Pacemaker and ICD Registry we identified all 1st-time prim......Aims: We aimed to examine the use of guideline recommended beta-blocker therapy prior to and after primary prevention implantable cardioverter defibrillator (ICD) implantation in a 'real-life' setting. Methods and results: From the Danish Pacemaker and ICD Registry we identified all 1st......-time primary prevention ICD and cardiac resynchronization therapy defibrillator (CRT-D) implantations in Denmark from 2007-12 (n = 2935). Use of beta-blocker, type and dose was acquired through the Danish Prescription Registry. According to guideline recommendations, we defined target daily doses as ≥50 mg...... carvedilol and ≥200 mg metoprolol. Prior to implantation 2427 of 2935 (83%) patients received beta-blocker therapy, with 2166 patients (89%) having initiated treatment 3 months or more prior to implantation. The majority of patients was prescribed carvedilol (52%) or metoprolol (41%). Patients on carvedilol...

  14. Capsule endoscopy in patients with cardiac pacemakers, implantable cardioverter defibrillators and left heart assist devices.

    Science.gov (United States)

    Bandorski, Dirk; Höltgen, Reinhard; Stunder, Dominik; Keuchel, Martin

    2014-01-01

    According to the recommendations of the US Food and Drug Administration and manufacturers, capsule endoscopy should not be used in patients carrying implanted cardiac devices. For this review we considered studies indexed (until 30.06.2013) in Medline [keywords: capsule endoscopy, small bowel endoscopy, cardiac pacemaker, implantable cardioverter defibrillator, interference, left heart assist device], technical information from Given Imaging and one own publication (not listed in Medline). Several in vitro and in vivo studies included patients with implanted cardiac devices who underwent capsule endoscopy. No clinically relevant interference was noticed. Initial reports on interference with a simulating device were not reproduced. Furthermore technical data of PillCam (Given Imaging) demonstrate that the maximum transmission power is below the permitted limits for cardiac devices. Hence, impairment of cardiac pacemaker, defibrillator or left ventricular heart assist device function by capsule endoscopy is not expected. However, wireless telemetry can cause dysfunction of capsule endoscopy recording. Application of capsule endoscopy is feasible and safe in patients with implanted cardiac devices such as pacemakers, cardioverter defibrillators, and left heart assist devices. Development of new technologies warrants future re-evaluation.

  15. Cardioverter-defibrillator implantation to treat cardiac fibroma-induced ventricular tachycardia in a 70-year-old woman.

    Science.gov (United States)

    Hakim, Fayaz Ahmad; Pandit, Anil; Mookadam, Farouk; Mamby, Sylvia

    2014-06-01

    Benign cardiac fibroma is rarely reported in adults. Its clinical symptoms are related to outflow obstruction or dysrhythmias. We present the case of a 70-year-old woman who had a syncopal episode from ventricular tachycardia caused by cardiac fibroma. Because of unfavorable tumor anatomy, the patient was not a candidate for surgical excision, and she declined orthotopic heart transplantation. To prevent sudden cardiac death, we placed an implantable cardioverter-defibrillator, and the patient remained well throughout the 2-year follow-up period. To our knowledge, this is the first report of implantable cardioverter-defibrillator therapy to treat an adult patient's unresectable cardiac fibroma.

  16. Employment Status and Sick Leave After First-Time Implantable Cardioverter Defibrillator Implantation

    DEFF Research Database (Denmark)

    Christensen, Anne Vinggaard; Øhlers, Anne Alexandrine; Zwisler, Ann Dorthe

    2017-01-01

    BACKGROUND:: In the Copenhagen Outpatient Programme–Implantable Cardioverter Defibrillator (COPE-ICD) Trial, a positive effect from a cost-saving, comprehensive cardiac rehabilitation program was found on physical and mental health in patients with ICDs. OBJECTIVE:: In the context of the COPE...... of employment status and sick leave were tested using logistic regression and linear regression models. RESULT:: A total of 196 patients were randomized. The questionnaire was completed by 138 patients (70%). In total, 47% had worked before ICD implantation. After 1 year, 81% were still working and their mean...

  17. Relation between emotional distress and heart rate variability in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Pedersen, Susanne S.; Theuns, Dominic A M J

    2014-01-01

    We investigated the relationship between Type D personality, depression, and anxiety, and heart rate variability (HRV) in 64 patients with an implantable cardioverter-defibrillator (ICD). HRV was obtained via 24-h Holter monitoring, and 24-h, 30-min daytime rest and 30-min nighttime sleep HRV were...... for depression (lower RMSSD: p = .10; lower pNN50: p = .09). During daytime rest, similar results were found for anxiety and depression. During sleep, only noteworthy adjusted associations were found for depression (lower root mean square of successive differences in NN intervals [RMSSD]: p = .06; lower pNN50: p...

  18. Venous Obstruction Following Pacemaker or Implantable Cardioverter-Defibrillator Implantation, Mini Review

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Akbarzadeh

    2016-08-01

    Full Text Available Venous obstruction is relatively frequent following permanent pacemaker or implantable cardioverter-defibrillator (ICD implantation. However, most of them are asymptomatic. Although the exact risk factor for this complication is not known, number of leads, heart failure and infection may prone the patient to this complication. The goal standard for detection of vein stenosis is venography; however, ultrasound sonography has an acceptable accuracy. Anticoagulant therapy may be considered for symptomatic patients. For device upgrading, non-functional leads removal, venoplasty and rarely surgical treatment may be indicated.

  19. Intensity of primary emotions in patients after implantation of an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Stoier, Louise; Pedersen, Preben Ulrich; Berg, Selina Kikkenborg

    2013-01-01

    Background: Experienced emotions can affect the outcome of, and adherence to a cardiac rehabilitation program, and patients coping with an illness. With more awareness of the expressed emotions, health professionals might be better able to understand the reactions of patients and to improve...... the support needed for coping. Living with an Implantable Cardi- overter Defibrillator can lead to anxiety and depression. Focus on the intensity of the primary emotions might be a potential to prevent development of these psychological states. Objectives: The aim of this paper are 1) to describe...... the intensity of primary emotions in patients after implantation of an Implantable Cardioverter Defibrillator and 2) to compare them with both the intensity of primary emotions in patients with a recent Myocardial Infarction and with a healthy population. Method: The intensity of primary emotions in patients...

  20. Intensity of primary emotions in patients after implantation of an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Stoier, Louise; Pedersen, Preben Ulrich; Berg, Selina Kikkenborg

    2013-01-01

    Background: Experienced emotions can affect the outcome of, and adherence to a cardiac rehabilitation program, and patients coping with an illness. With more awareness of the expressed emotions, health professionals might be better able to understand the reactions of patients and to improve...... the support needed for coping. Living with an Implantable Cardi- overter Defibrillator can lead to anxiety and depression. Focus on the intensity of the primary emotions might be a potential to prevent development of these psychological states. Objectives: The aim of this paper are 1) to describe...... the intensity of primary emotions in patients after implantation of an Implantable Cardioverter Defibrillator and 2) to compare them with both the intensity of primary emotions in patients with a recent Myocardial Infarction and with a healthy population. Method: The intensity of primary emotions in patients...

  1. Bilateral Subclavian Vein Occlusion in a SAPHO Syndrome Patient Who Needed an Implantable Cardioverter Defibrillator.

    Science.gov (United States)

    Ishizuka, Masato; Yamamoto, Yuko; Yamada, Shintaro; Maemura, Sonoko; Nakata, Ryo; Motozawa, Yoshihiro; Yamamoto, Keisuke; Takizawa, Masataka; Uozumi, Hiroki; Ikenouchi, Hiroshi

    2016-05-25

    A 79-year-old Asian man was hospitalized because of progressive exertional dyspnea with decreasing left ventricular ejection fraction and frequent non-sustained ventricular tachycardia. Pre-procedure venography for implantable cardioverter defibrillator (ICD) implantation showed occlusion of the bilateral subclavian veins. In consideration of subcutaneous humps in the sterno-clavicular area and palmoplantar pustulosis, we diagnosed him as having synovitis, acne, pustulosis, hyperostosis, osteitis (SAPHO) syndrome and speculated that it induced peri-osteal chronic inflammation in the sterno-clavicular area, resulting in occlusion of the adjacent bilateral subclavian veins. An automatic external defibrillator (AED) was installed in the patient's house and total subcutaneous ICD was considered. Venous thrombosis in SAPHO syndrome is not frequent but has been reported. To the best of our knowledge, this is the first case of bilateral subclavian vein occlusion in a SAPHO syndrome patient who needs ICD implantation.

  2. Successful use of wearable cardioverter defibrillator in a patient with dextrocardia and persistent left superior vena cava.

    Science.gov (United States)

    Wan, Chingping; Oren, Jess W; Szymkiewicz, Steven J

    2013-09-01

    Congenital disorders, such as dextrocardia and persistent left superior vena cava, are rare. However, their presence is often associated with other cardiac anomalies, and may lead to lethal ventricular tachyarrhythmias, which result in sudden cardiac death. Treating patients with these disorders can present a challenge to clinicians, as it may cause technical difficulties during interventional procedures, and more often, altered defibrillation techniques in a setting of prehospital sudden cardiac arrest. This report describes the first case of successful defibrillation therapy delivered by the wearable cardioverter defibrillator to a patient with dextrocardia and persistent left superior vena cava during a ventricular tachycardia arrest.

  3. [Implantable cardioverter-defibrillator deactivation at the end of life: ethical, clinical and communication issues].

    Science.gov (United States)

    Romanò, Massimo; Piga, Maria Antonella; Bertona, Roberta; Negro, Roberto; Ruggeri, Chiara; Zorzoli, Federica; Villani, Rosvaldo

    2017-02-01

    The number of cardioverter-defibrillator implants is increasing worldwide, with the main indication being primary prevention of sudden cardiac death. During the follow-up, patients may die from progression of their underlying heart disease or from nonarrhythmic causes, such as malignancies, dementia and lung disease, without receiving appropriate shocks until the last few days or weeks of their life. These events occur roughly in 30% of patients, mainly in the last 24 hours before death. In this case, inappropriate and even appropriate shock deliveries can no longer prolong life and may simply lead to pain and reduced quality of life. Therefore, it appears important to discuss early with the patients and their relatives about deactivation of the implantable cardioverter-defibrillator (ICD) at the end of life.The goal of this review is to provide an overview of the ethical, clinical and communication issues of ICD deactivation, with a special focus on patients' wishes. It is outlined that patients are not adequately informed about risks and benefits of ICD and the option of ICD deactivation; the doctors are not used to discuss with the patients the topics of end-of-life decisions. Complete information must be part of current informed consent before ICD implantation and should be updated during the follow-up, with special attention to patients with heart failure in relation to their prognosis and advance directives, as suggested by international guidelines.

  4. Economical aspect of PET/CT-guided diagnosis of suspected infective endocarditis in a patient with implantable cardioverter-defibrillator.

    Science.gov (United States)

    Farkowski, Michal M; Milkowski, Maciej; Dziuk, Mirosław; Pytkowski, Mariusz; Marciniak, Marta; Kraska, Alicja; Szwed, Hanna; Sterlinski, Maciej

    2014-01-01

    We present a case report of potential reduction of hospitalization costs due to utilization of PET/CT in a diagnostic work-up of a patient with an implantable cardioverter-defibrillator and suspicion of infective endocarditis. The PET/CT scan would have shorten hospital stay, prevented clinical complications and reduced the cost of hospitalization by 45%.

  5. Patient-reported outcomes in Danish implantable cardioverter defibrillator patients with a Sprint Fidelis lead advisory notification

    DEFF Research Database (Denmark)

    Pedersen, Susanne S; Versteeg, Henneke; Nielsen, Jens Cosedis;

    2011-01-01

    Few studies have investigated the association between implantable cardioverter defibrillators (ICDs) and lead advisory notifications and patient-reported outcomes (PROs). We examined (i) whether the mode used to inform patients about a device advisory is associated with PROs, and (ii) whether pat...

  6. Morphology discrimination in implantable cardioverter-defibrillators: Consistency of template match percentage during atrial tachyarrhythmias at different heart rates

    NARCIS (Netherlands)

    D.A.M.J. Theuns (Dominic); M. Rivero-Ayerza (Maximo); D. Goedhart (Dick); M. Miltenburg (Max); L.J.L.M. Jordaens (Luc)

    2008-01-01

    textabstractBackground: Morphology discrimination (MD) in implantable cardioverter-defibrillators (ICDs) is based on the comparison of the ventricular electrogram during tachycardia with a stored reference template obtained during baseline rhythm. However, the effect of heart rate on the template ma

  7. Conscious sedation as an anaesthetic technique in patients undergoing nonthoracotomy placement of automatic implantable cardioverter defibrillator : an initial experience.

    Directory of Open Access Journals (Sweden)

    Singh V

    2004-01-01

    Full Text Available Six adult patients with life threatening recurrent ventricular arrhythmias who underwent non- thoracotomy placement of automatic implantable cardioverter defibrillator under conscious sedation are reported. Our clinical experience, patient satisfaction, recovery profile, complications and cardiologist perception about the technique of conscious sedation is presented and discussed.

  8. Psychological Functioning and Disease-Related Quality of Life in Pediatric Patients With an Implantable Cardioverter Defibrillator

    NARCIS (Netherlands)

    Koopman, H. M.; Vrijmoet-Wiersma, C. M. J.; Langius, J. N. D.; van den Heuvel, F.; Clur, S. A.; Blank, C. A.; Blom, N. A.; ten Harkel, A. D. J.

    2012-01-01

    The objective of this multicenter study was to evaluate psychological functioning and disease-related quality of life (DRQoL) in pediatric patients with an implantable cardioverter defibrillator (ICD) in The Netherlands. Thirty patients were investigated; the mean age was 16.3 years, and the mean du

  9. A review of economic evaluation models for cardiac resynchronization therapy with implantable cardioverter defibrillators in patients with heart failure

    NARCIS (Netherlands)

    Tomini, F.; van Asselt, A. D.

    2012-01-01

    OBJECTIVES: Cardiac resynchronization therapy with biventricular pacemaker (CRT-P) is considered an effective treatment for heart failure (HF). Adding implantable cardioverter defibrillators (CRT-D) may further reduce the risk of sudden cardiac death (SCD). However, economic evaluations have shown t

  10. Shock and patient preimplantation type D personality are associated with poor health status in patients with implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Tekle, Fetene B; Hoogwegt, Madelein T

    2012-01-01

    Implantable cardioverter-defibrillator (ICD) shock is a critical event to patients associated with well-being after implantation, although other factors may play an equally important role. We compared the association of shock and the patient's preimplantation personality with health status, using...

  11. [The Wearable Cardioverter Defibrillator (WCD) for the prevention of sudden cardiac death -- a single center experience].

    Science.gov (United States)

    Reek, S; Meltendorf, U; Geller, J C; Wollbrück, A; Grund, S; Klein, H U

    2002-12-01

    The Wearable Cardioverter Defibrillator (WCD) is an external defibrillator that automatically detects and treats ventricular tachyarrhythmias without the need for assistance from a bystander while at the same time allowing the patient to ambulate freely. The main components of the system are the defibrillator unit and a chest belt with electrodes for arrhythmia detection and therapy delivery. Between December 1998 and October 2001, 84 patients used the device at our institution. The majority of patients had a history of acute myocardial infarction or coronary artery bypass surgery with an increased risk for sudden cardiac death or were awaiting heart transplantation. During a mean follow-up of 116+/-90 days, 7 episodes of ventricular tachyarrhythmias were detected and terminated successfully by the WCD in 5 patients. In 9720 days, there was one inappropriate shock due to oversensing of electrical noise. Four patients died during follow-up; none of them had a cardiac arrest while wearing the device. Five patients were excluded because of irregularities in device use. An ICD was implanted in 24 patients at the end of the follow-up period. The WCD is effective in detecting and treating ventricular tachyarrhythmias in patients with an intermittently increased risk for sudden cardiac death. Further use of the system in larger patient populations is needed to confirm its safety and cost effectiveness.

  12. The effect of intermittent atrial tachyarrhythmia on heart failure or death in cardiac resynchronization therapy with defibrillator versus implantable cardioverter-defibrillator patients

    DEFF Research Database (Denmark)

    Ruwald, Anne-Christine; Pietrasik, Grzegorz; Goldenberg, Ilan;

    2014-01-01

    OBJECTIVES: This study aimed to investigate the effect of both history of intermittent atrial tachyarrhythmias (IAT) and in-trial IAT on the risk of heart failure (HF) or death comparing cardiac resynchronization therapy with defibrillator (CRT-D) to implantable cardioverter-defibrillator (ICD......, respectively, a history of IAT at baseline and time-dependent development of in-trial IAT during follow-up in 1,264 patients with LBBB enrolled in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy) study. RESULTS: The overall beneficial effect of CRT...... of in-trial atrial tachyarrhythmias. (MADIT-CRT: Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy; NCT00180271)....

  13. Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients - Results from the PREPARE (Primary Prevention Parameters Evaluation) study

    NARCIS (Netherlands)

    Wilkoff, Bruce L.; Williamson, Brian D.; Stern, Richard S.; Moore, Stephen L.; Lu, Fei; Lee, Sung W.; Birgersdotter-Green, Ulrika M.; Wathen, Mark S.; Van Gelder, Isabelle C.; Heubner, Brooke M.; Brown, Mark L.; Holloman, Keith K.

    2008-01-01

    Objectives Our purpose was to demonstrate that strategically chosen implantable cardioverter-defibrillator (ICD) ventricular tachycardia (VT) or ventricular fibrillation (VF) detection and therapy parameters can reduce the combined incidence of device-delivered shocks, arrhythmic syncope, and untrea

  14. Influence of diabetes mellitus on inappropriate and appropriate implantable cardioverter-defibrillator therapy and mortality in the Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT) Trial

    DEFF Research Database (Denmark)

    Ruwald, Martin H.; Zareba, Wojciech; Jons, Christian;

    2013-01-01

    The relationship between diabetes mellitus and risk of inappropriate or appropriate therapy in patients receiving an implantable cardioverter-defibrillator (ICD) and resynchronization therapy has not been investigated thoroughly. The effect of innovative ICD programming on therapy delivery in the...

  15. Type D personality is associated with increased anxiety and depressive symptoms in patients with an implantable cardioverter defibrillator and their partners

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van Domburg, Ron T; Theuns, Dominic A M J;

    2014-01-01

    We investigated the prevalence of anxiety and depressive symptoms in patients with an implantable cardioverter defibrillator (ICD) and their partners, and the role of personality factors and social support as determinants of distress.......We investigated the prevalence of anxiety and depressive symptoms in patients with an implantable cardioverter defibrillator (ICD) and their partners, and the role of personality factors and social support as determinants of distress....

  16. Relation of statin therapy to psychological functioning in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Theuns, Dominic A M J; Kupper, Nina

    2013-01-01

    Statin therapy is an important secondary prevention measure in cardiovascular disease. However, the side effects associated with statin use could potentially affect patients' quality of life. Little is known about the influence of statin therapy on the well-being and health status of cardiac...... patients, in general, and patients with an implantable cardioverter defibrillator (ICD), in particular. We investigated the association between statin therapy and symptoms of anxiety and depression and patients' health status during the 12 months after implantation, reckoning with statin type and dosage....... Consecutively implanted ICD patients (n = 409; 78.2% men) completed the Hospital Anxiety and Depression Scale and the Medical Outcomes Study Short Form 36-item Health Survey at baseline and 3, 6, and 12 months after implantation. The data were analyzed using general linear mixed modeling repeated measures...

  17. E-Health to Manage Distress in Patients With an Implantable Cardioverter-Defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; Denollet, Johan; Cuijpers, Pim

    2014-01-01

    for anxiety (β = 0.35; p = .32), depression (β = -0.01; p = .98) or health-related quality of life (Mental Component Scale: β = 0.19; p = .86; Physical Component Scale: β = 0.58; p = .60) at 3 months, with effect sizes (Cohen d) being small (range, 0.06-0.13). There were also no significant group differences...... based on the problem-solving principles of cognitive behavioral therapy. RESULTS: Two hundred eighty-nine patients (85% response rate) were randomized. The prevalence of anxiety and depression ranged between 11% and 30% and 13% and 21%, respectively. No significant intervention effects were observed......UNLABELLED: The Web-based distress management program for patients with an implantable cardioverter-defibrillator (ICD; WEBCARE) was developed to mitigate distress and enhance health-related quality of life in ICD patients. This study investigated the treatment effectiveness at 3-month follow...

  18. Attitudes towards implantable cardioverter-defibrillator therapy: a national survey in Danish health-care professionals

    DEFF Research Database (Denmark)

    Johansen, Jens B; Mortensen, Peter T; Videbæk, Regitze

    2011-01-01

    Aims The aim of this study was to examine health-care professionals attitudes towards implantable cardioverter-defibrillator (ICD) therapy and issues discussed with patients. Methods and results Survey of 209 health-care professionals providing specialized treatment and care of ICD patients......-physicians. Physicians were less likely to believe that their personal attitude towards ICD treatment has no influence on how they deal professionally with patients (27.8 vs. 43.6%; P = 0.04). Physicians and non-physicians were equally positive towards ICD therapy as primary prophylaxis in ischaemic cardiomyopathy (87...... discussing ICD treatment with candidate patients. At the same time, physicians are more aware that their attitude towards ICD treatment may influence how they deal professionally with patients compared with non-physicians....

  19. Epileptic seizure in a patient with an implantable cardioverter-defibrillator: Quo vadis right ventricular lead?

    Science.gov (United States)

    Wedekind, Horst; Rozhnev, Andrey; Kleine-Katthöfer, Peter; Kranig, Wolfgang

    2016-03-01

    The case of a 77-year-old man admitted for suspected epileptic seizure is reported. Patient history showed implantation of a single-chamber implantable cardioverter-defibrillator (ICD) after cardiac arrest in 2007 with replacement in 2012 due to battery depletion; the patient reported no previous syncope, unconsciousness or seizures. Interrogation records of the ICD showed five ventricular tachyarrhythmia episodes that corresponded to the "seizure". Further examination revealed incorrect position of the RV-lead. Diagnosis was a provoked epileptic seizure due to undersensing of ventricular tachycardia because of improper ICD lead implantation in the coronary sinus. Treatment consisted of implantation of a new device with an additional ICD lead into the right ventricle.

  20. Clinical effects and implications of cardiac rehabilitation for implantable cardioverter defibrillator patients

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Moons, Philip; Christensen, Anne Vingaard

    2015-01-01

    further explained by the qualitative findings. Patients with better physical health learned how to interpret body signals and adjust exercise behavior and experienced increased physical capacity. Those with better mental health received support that assisted them to cope with the possibility of shock...... rehabilitation and usual care was found in physical capacity and general and mental health. However, the clinical effect sizes of these findings were not investigated, and the findings from the quantitative and qualitative analyses were not triangulated to address the issue of whether the qualitative results......-time implantable cardioverter defibrillator implantation were randomized (1:1) to comprehensive cardiac rehabilitation (12 weeks of exercise training and 1 year of psychoeducational follow-up) versus treatment as usual. Two primary outcomes, perceived health (Short Form-36) and peak oxygen uptake, were used. Cohen...

  1. Gender disparities in psychological distress and quality of life among patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Brouwers, Corline; van den Broek, Krista C; Denollet, Johan

    2011-01-01

    disparities in psychological distress and QoL in ICD patients by means of a systematic review, and (2) provide recommendations for future research and clinical implications. A systematic search of the literature identified 18 studies with a sample size ≥ 100 that examined gender disparities in anxiety......A subset of patients with an implantable cardioverter defibrillator (ICD) reports psychological distress and poor quality of life (QoL). Gender is one of the factors that has been proposed to explain individual differences in these outcomes. In this viewpoint, we (1) review the evidence for gender....../depression and QoL in ICD patients (mean prevalence of women = 21%; mean age = 62 years). Our review shows that there is insufficient evidence to conclude that gender per se is a major autonomous predictor for disparities in psychological distress and QoL in ICD patients. Women had a higher prevalence of anxiety...

  2. [Automatic, implantible cardioverter-defibrillator in a patient with chronic Chagas cardiopathy and sustained ventricular tachycardia].

    Science.gov (United States)

    Rodríguez, H; Muñoz, M; Llamas, G; Iturralde, P; Medeiros, A; Delgado, L; Mar, R; Rucinque, F; Bayram, E

    1998-01-01

    We studied a 48 years old woman, with chronic Chagasic cardiopathy, manifested with cardiomegaly, heart failure and syncope, due to a sustained ventricular tachycardia (SVT) of two different configurations (left bundle branch block and right bundle branch block). During electrophysiological testing, both types of ventricular tachycardia were reproduced. Successful ablation therapy of the right branch of His was performed due to suspicion of the bundle branch reentrant tachycardia, with a left bundle branch block. The patient continued to show SVT episodes, now with right bundle branch block pattern. Cardioverter Defibrillator was implanted. We report this case due to the rare frequency of Chagas' disease, where it could be a cause of heart disease, since the existence of the parasite (trypanosoma cruzi) and its vector (Triatoma) has been identified in some rural and suburban zones in the state of Aguascalientes, Mexico.

  3. Comprehensive cardiac rehabilitation improves outcome for patients with implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Pedersen, Preben Ulrich; Zwisler, Ann-Dorthe

    2015-01-01

    Aims:The aim of this randomised clinical trial was to assess a comprehensive cardiac rehabilitation intervention including exercise training and psycho-education vs 'treatment as usual' in patients treated with an implantable cardioverter defibrillator (ICD).Methods:In this study 196 patients...... with first time ICD implantation (mean age 57.2 (standard deviation (SD)=13.2); 79% men) were randomised (1:1) to comprehensive cardiac rehabilitation vs 'treatment as usual'. Altogether 144 participants completed the 12 month follow-up. The intervention consisted of twelve weeks of exercise training and one...... year of psycho-educational follow-up focusing on modifiable factors associated with poor outcomes. Two primary outcomes, general health score (Short Form-36 (SF-36)) and peak oxygen uptake (VO2), were used. Post-hoc analyses included SF-36 and ICD therapy history.Results:Comprehensive cardiac...

  4. Posttraumatic stress and anxiety in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; Denollet, J; Pedersen, S S

    2017-01-01

    the trajectories of symptoms of posttraumatic stress disorder (PTSD) and anxiety in patients with an ICD and the vulnerability factors associated with an increased risk of symptoms of PTSD and anxiety. METHODS: A total of 249 patients were included as part of the WEB-based distress program for implantable...... CARdioverter dEfibrillator patients (WEBCARE) study. Data were analyzed using Latent class analyses, with trajectories of PTSD symptomatology and anxiety examined between baseline and 12 months follow-up. RESULTS: The mean age of the sample was 58.9±9.8, with the majority being male (82%). Latent Class...... analyses (LatentGOLD) revealed four classes with respect to PTSD symptomatology, and three classes of patients with respect to anxiety. Younger age, increased depression score at baseline, and Type D personality were all associated with increased vulnerability for posttraumatic stress and anxiety symptoms...

  5. Experience of elderly Spanish men with an implantable cardioverter-defibrillator.

    Science.gov (United States)

    Palacios-Ceña, Domingo; Losa-Iglesias, Marta Elena; Salvadores-Fuentes, Paloma; Alonso-Blanco, Cristina; Fernández-de-Las-Peñas, Cesar

    2011-07-01

    An implantable cardioverter-defibrillator is the treatment of choice for ventricular arrhythmias and sudden death. Clinical trials and qualitative studies normally exclude elderly patients. The aim of this study was to describe the experience of elderly Spanish men with an implantable cardioverter-defibrillator. This was a qualitative phenomenological study. Sampling was purposeful and used the snowball technique. Unstructured interviews and recipients' personal accounts were collected. Data collection finished with information saturation. Analysis was performed using the Giorgi proposal with triangulation between research-team members. Data were audited by an external researcher. The change and the need to adapt to the new situation can be perceived as a loss of independence by the elderly. The significance of the partner in the Spanish context is particularly relevant during the narration. Also, their view of the world is transformed, they experience an internal change. Additionally, the elderly patient may become confined to their home and shut off from their surroundings, accompanied by a sensation of being "stuck" and "imprisoned" by their own process. Elderly recipients can end up "clinging on" to customs as they are felt to define the recipient's identity and utility within their social and personal context. Their partner is of huge significance for elderly recipients. The geriatric health personnel must contribute to promote and maintain activities of daily living in elderly. Future qualitative studies taking an in-depth look at the experience and readjustment process of elderly recipients and the relationship among older people and technological equipment should be further conducted. © 2011 Japan Geriatrics Society.

  6. OVERSENSING AS A CAUSE OF INAPPROPRIATE IMPLANTABLE CARDIOVERTER- DEFIBRILLATOR THERAPY - CASE REPORT

    Directory of Open Access Journals (Sweden)

    Tomislav Kostić

    2013-12-01

    Full Text Available Technology development in the recent years has enabled that both prevention and treatment of life-threatening heart rhythm disorders are managed by implantable cardioverter-defibrillators. Clinical studies have confirmed the advantage of this type of therapy in the prevention of sudden cardiac death in the recent years, so the use of ICDs has became a clinical routine. Rarely functional disturbances of those devices could be seen as undetected malignant arrhythmias (undersensing or false detection of a normal heart rhythm (oversensing. Patient N.S. aged 67 years was admitted to Cardiology Clinic, Clinical Center Niš because of inappropriate sequential therapy of implantable cardioverter-defibrillator (ICD (12 shocks were delivered within 48 hours before admission. ICD pacemaker was implanted four years before the admission due to dilated cardiomyopathy (LVEF 25%. Based on a detailed analysis of the device’s parameters the rapid increase in ventricular lead impedance was established (it was > 3000Ω; and the normal range is 250-2000 Ω. It was found that oversensing was the cause of sequential shocks delivery with energy of 35 J. The damaged lead of the ICD detected false signals as VF (ventricular fibrillation and applied therapy. On the third day of hospitalization, the patient received an ICD Medtronic Maximo II device with the active electrode Medtronic Sprint Quattro 6947 but the left atrial electrode was not displaced. Prophylactic antibiotic therapy was given and patient was discharged 5 days after implantation. After one month at the control visit device parameters were satisfactory, the sensing function was appropriate with good impedance of the lead. Special feature of these devices is the need for individual programming, tailored to each patient, so it is necessary for a center that performs the implantation to have a medical team that has experience in the application of this type of therapy.

  7. Rationale and design of the PRAETORIAN trial: A Prospective, RAndomizEd comparison of subcuTaneOus and tRansvenous ImplANtable cardioverter- defibrillator therapy

    NARCIS (Netherlands)

    L.R.A. Olde Nordkamp (Louise R.A.); R.E. Knops (Reinoud); G.H. Bardy (Gust); Y. Blaauw (Yuri); L. Boersma (Lucas); J.S. Bos (Johannes); P.P.H.M. Delnoy (Peter Paul); P.F.H.M. van Pascal; A.H.G. Driessen (Antoine); J.R. de Groot (Joris); J.P.R. Herrman; L.J.L.M. Jordaens (Luc); K.M. Kooiman (Kirsten); A.H. Maass (Alexander); M. Meine (Mathias); Y. Mizusawa (Yuka); S.G. Molhoek (Sander); J. van Opstal (Jurjen); J.G.P. Tijssen (Jan); A.A.M. Wilde (Arthur)

    2012-01-01

    textabstractBackground: Implantable cardioverter-defibrillators (ICDs) are widely used to prevent fatal outcomes associated with life-threatening arrhythmic episodes in a variety of cardiac diseases. These ICDs rely on transvenous leads for cardiac sensing and defibrillation. A new entirely subcutan

  8. Concomitant Use of the Subcutaneous Implantable Cardioverter Defibrillator and a Permanent Pacemaker.

    Science.gov (United States)

    Huang, Jason; Patton, Kristen K; Prutkin, Jordan M

    2016-11-01

    The subcutaneous implantable cardioverter defibrillator (S-ICD) is a novel implanted defibrillator for the prevention of sudden cardiac death that avoids intravascular access. Use of this device is limited by its inability to provide backup pacing. Combined use of the S-ICD with a permanent pacemaker may be the optimal choice in certain situations though experience with the use of both devices together remains limited. We reviewed our single-center experience with the S-ICD from March 2011 to November 2015. Four patients with concomitant use of the S-ICD and a permanent pacemaker were identified. Clinical indication for device therapy, operative details, and subsequent follow-up was reviewed. During implantation, S-ICD sensing of paced morphologies was evaluated at maximal voltage output. After S-ICD implant, if feasible, the upper rate was adjusted to ≤50% of the S-ICD tachycardia zone to minimize risk of inappropriate shocks. After a mean follow-up of over 1 year, no adverse events occurred, including no inappropriate shock, lead malfunction, or device infection. One patient had a total of eight appropriate shocks, while another individual had no inappropriate shocks despite having a unipolar pacing lead. In unique situations, combined use of the S-ICD and a permanent pacemaker may be preferable to alternative options. In our experience, this approach was successful in varying conditions including complex congenital heart disease, recurrent device infection, and limited vascular access. © 2016 Wiley Periodicals, Inc.

  9. General anaesthesia for insertion of an automated implantable cardioverter defibrillator in a child with Brugada and autism

    Directory of Open Access Journals (Sweden)

    Shwetal Goraksha

    2010-01-01

    Full Text Available A 14-year-old autistic boy presented with acute gastroenteritis and hypotension. The electrocardiogram showed a ventricular fibrillation rhythm - he went into cardiorespiratory arrest and was immediately resuscitated. On investigation, the electrocardiogram showed a partial right bundle branch block with a "coved" pattern of ST elevation in leads v 1 -v 3 . A provisional diagnosis of Brugada syndrome was made, for which an automated implantable cardioverter defibrillator (AICD implantation was advised. Although the automated implantable cardioverter defibrillator implantation is usually performed under sedation, because this was an autistic child, he needed general anaesthesia. We performed the procedure uneventfully under general anaesthesia and he was discharged after a short hospital stay.

  10. Selective left ventricular sensing lead implantation to overcome undersensing of ventricular fibrillation during implantable cardioverter defibrillator implantation.

    Science.gov (United States)

    Steinberg, Christian; Philippon, François; O'Hara, Gilles; Molin, Franck

    2013-06-01

    Accurate sensing of malignant arrhythmia is critical for the appropriate delivery of therapy from implantable cardioverter defibrillators, and undersensing of ventricular tachyarrhythmias can have catastrophic consequences. Here, we present an unusual case of ventricular fibrillation undersensing from the right ventricular lead at multiple different implantation sites because of very low amplitude voltage signals during induced ventricular fibrillation. A left ventricular sensing electrode was implanted to allow correct sensing and therapy delivery.

  11. Obstetric hemorrhage in a case of hypertrophic obstructive cardiomyopathy with automatic implantable cardioverter defibrillator: Anaesthesia and intensive care management.

    Science.gov (United States)

    Mishra, Sandeep Kumar; Bhat, Ravindra R; Kavitha, Jayaram; Kundra, Pankaj; Parida, Satyen

    2016-01-01

    The physiological changes occurring during pregnancy and labor may reveal or exacerbate the symptoms of hypertrophic obstructive cardiomyopathy (HOCM). The addition of obstetric hemorrhage to this presents a unique challenge to the anesthesiologists and intensivists managing these patients in the operation theatres and the Intensive Care Units. Here we present a case of HOCM with automatic implantable cardioverter defibrillator in situ and postpartum hemorrhagic shock.

  12. Implant and clinical characteristics for pediatric and congenital heart patients in the national cardiovascular data registry implantable cardioverter defibrillator registry.

    Science.gov (United States)

    Jordan, Christopher P; Freedenberg, Vicki; Wang, Yongfei; Curtis, Jeptha P; Gleva, Marye J; Berul, Charles I

    2014-12-01

    In 2010, the National Cardiovascular Data Registry enhanced pediatric, nonatherosclerotic structural heart disease and congenital heart disease (CHD) data collection. This report characterizes CHD and pediatric patients undergoing implantable cardioverter defibrillator implantation. In this article, we report implantable cardioverter defibrillator procedures (April 2010 to December 2012) in the registry for 2 cohorts: (1) all patients with CHD (atrial septal defect, ventricular septal defect, tetralogy of Fallot, Ebstein anomaly, transposition of the great vessels, and common ventricle) and (2) patients implants, CHD type, and New York Heart Association class. There were 3139 CHD procedures, 1601 for patients Implantable cardioverter defibrillator indications for patients with CHD were primary prevention in 1943 (61.9%) and secondary prevention in 1107 (35.2%). Pediatric patients had 935 (58.4%) primary prevention and 588 (36.7%) secondary prevention devices. Primary prevention had higher New York Heart Association class. Nontransvenous age (35.9 ± 23.2 versus 40.1 ± 24.6 years; P=0.05) and nontransvenous height (167.1 ± 18.9 cm; range, 53-193 cm versus 170.4 ± 13.1 cm; range, 61-203 cm; PHeart Association, Inc.

  13. Remote monitoring of implantable cardioverter-defibrillators. Problems and implications using a telemonitoring system.

    Science.gov (United States)

    Siebermair, J; Clauss, S; Martens, E; Schuessler, F; Oversohl, N; Haserueck, N; Estner, H L; Kääb, S; Wakili, R

    2015-04-01

    The rising number of implantable devices has led to an increase in device-related workload, e.g., regular interrogation follow-up visits. Telemonitoring systems for implantable cardioverter-defibrillators (ICDs) seem to be a promising tool for reducing workload and costs, and they have the potential of optimizing patient care. However, issues such as practical functionality of ICD telemonitoring in daily routine may affect its broad implementation. The objective of this study was to evaluate potential problems during the implementation of a telemonitoring system, Medtronic CareLink™ (CL™) with respect to the installation and data transmission process. A total of 159 patients with ICDs who were equipped with the CL™ system were evaluated and followed up for 16 months regarding the success rate of the first data transmission via the telemonitoring system. In this cohort, a high rate of nontransmission of 23.9 % was observed after the 16-month follow-up. A detailed interview of these patients (no transmission) revealed that the main reasons for failed transmissions were due to the patients' loss of interest in the concept (approximately 50 %) as well as technical problems (approximately 25 %) with setting up the system. These results indicate that telemonitoring systems bear potential problems and that the evaluation of patient motivation and technical support options seems to play an important role in establishing the functionality of these systems.

  14. Changes in psychosocial distress in outpatients with heart failure with implantable cardioverter defibrillators.

    Science.gov (United States)

    Thomas, Sue A; Friedmann, Erika; Gottlieb, Stephen S; Liu, Fang; Morton, Patricia G; Chapa, Deborah W; Lee, Hyeon-Joo; Nahm, Eun-Shim

    2009-01-01

    Patients given implantable cardioverter defibrillators (ICDs) after arrhythmic events or sudden cardiac arrest (SCA) experience psychosocial distress. ICDs now are inserted for the primary prevention of SCA in patients with heart failure; the psychosocial impact of ICDs on patients with heart failure is unknown. Changes in psychosocial status in these ICD recipients were examined. ICD recipients (n = 57) completed depression, anxiety, and social support inventories every 6 months for up to 2 years. Initially, 35% of recipients were depressed and 45% of recipients were anxious. In linear mixed models, depression decreased over time overall but increased in those who experienced ICD shocks. Anxiety decreased in New York Heart Association class III ICD recipients but not in class II ICD recipients. Decreases in social support were related to age: the younger the patient the greater the decrease. A significant proportion of ICD recipients were depressed or anxious, or had diminished social support even after 2 years. Investigation of strategies to improve ICD recipients' psychosocial status is warranted.

  15. Clinical Course After Cardioverter-Defibrillator Implantation: Chagasic Versus Ischemic Patients

    Science.gov (United States)

    Pereira, Francisca Tatiana Moreira; Rocha, Eduardo Arrais; Monteiro, Marcelo de Paula Martins; Lima, Neiberg de Alcantara; Rodrigues Sobrinho, Carlos Roberto Martins; Pires Neto, Roberto da Justa

    2016-01-01

    Background: The outcome of Chagas disease patients after receiving implantable cardioverter defibrillator (ICD) is still controversial. Objective: To compare clinical outcomes after ICD implantation in patients with chronic Chagas cardiomyopathy (CCC) and ischemic heart disease (IHD). Methods: Prospective study of a population of 153 patients receiving ICD (65 with CCC and 88 with IHD). The devices were implanted between 2003 and 2011. Survival rates and event-free survival were compared. Results: The groups were similar regarding sex, functional class and ejection fraction. Ischemic patients were, on average, 10 years older than CCC patients (p < 0.05). Patients with CCC had lower schooling and monthly income than IHD patients (p < 0.05). The number of appropriate therapies was 2.07 higher in CCC patients, who had a greater incidence of appropriate shock (p < 0.05). Annual mortality rate and electrical storm incidence were similar in both groups. There was no sudden death in CCC patients, and only one in IHD patients. Neither survival time (p = 0.720) nor event-free survival (p = 0.143) significantly differed between the groups. Conclusion: CCC doubles the risk of receiving appropriate therapies as compared to IHD, showing the greater complexity of arrhythmias in Chagas patients. PMID:27411097

  16. Arrhythmia Management in the Elderly-Implanted Cardioverter Defibrillators and Prevention of Sudden Death.

    Science.gov (United States)

    Manian, Usha; Gula, Lorne J

    2016-09-01

    We present an overview of arrhythmia management in elderly patients as it pertains to implantable cardioverter defibrillator (ICD) therapy and prevention of sudden death. Treatment of arrhythmia in elderly patients is fraught with challenges pertaining to goals of care and patient frailty. With an ever increasing amount of technology available, realistic expectations of therapy need to balance quality and quantity of life. The ICD is an important treatment option for selected patients at risk of ventricular arrhythmia and sudden cardiac death. However, the incidence of sudden death as a percentage of all-cause mortality decreases with age. Studies have reported that 20% of elderly patients might die within 1 year of an episode of life-threatening ventricular arrhythmia, but most because of nonarrhythmic causes. This illustrates the 'sudden cardiac death paradox,' with a great proportion of death in elderly patients, even those at risk for ventricular arrhythmias, attributable to medical conditions that cannot be addressed by an ICD. We discuss current practices in ICD therapy in elderly patients, existing evidence from registries and clinical trials, approaches to risk stratification, and important ethical considerations. Although the decision on whether ICD insertion is appropriate in the elderly population remains an area of uncertainty from an evidence-based and ethical perspective, we offer insight on potential clinical and research strategies for this growing population.

  17. [Guidelines on the management of implantable cardioverter defibrillators at the end of life].

    Science.gov (United States)

    Datino, T; Rexach, L; Vidán, M T; Alonso, A; Gándara, Á; Ruiz-García, J; Fontecha, B; Martínez-Sellés, M

    2014-01-01

    This article is a joint document of the Spanish Society of Geriatrics and Gerontology, the Spanish Society of Palliative Care and the Section of Geriatric Cardiology of the Spanish Society of Cardiology. Its aim is to address the huge gap that exists in Spain with regard to the management of implantable cardioverter defibrillators (ICDs) in the final stages of life. It is increasingly common to find patients carrying these devices that are in the terminal stage of an advanced disease. This occurs in patients with advanced heart disease and subsequent heart failure refractory to treatment but also in a patient with an ICD who develops cancer disease, organ failure or other neurodegenerative diseases with poor short-term prognosis. The vast majority of these patients are over 65, so the paper focuses particularly on the elderly who are in this situation, but the decision-making process is similar in younger patients with ICDs who are in the final phase of their life. Copyright © 2013 SEGG. Published by Elsevier Espana. All rights reserved.

  18. Guidelines on the management of implantable cardioverter defibrillators at the end of life.

    Science.gov (United States)

    Datino, T; Rexach, L; Vidán, M T; Alonso, A; Gándara, Á; Ruiz-García, J; Fontecha, B; Martínez-Sellés, M

    2014-01-01

    This article is a joint document of the Spanish Society of Geriatrics and Gerontology, the Spanish Society of Palliative Care and the Section of Geriatric Cardiology of the Spanish Society of Cardiology. Its aim is to address the huge gap that exists in Spain with regard to the management of implantable cardioverter defibrillators (ICDs) in the final stages of life. It is increasingly common to find patients carrying these devices that are in the terminal stage of an advanced disease. This occurs in patients with advanced heart disease and subsequent heart failure refractory to treatment but also in a patient with an ICD who develops cancer disease, organ failure or other neurodegenerative diseases with poor short-term prognosis. The vast majority of these patients are over 65, so the paper focuses particularly on the elderly who are in this situation, but the decision-making process is similar in younger patients with ICDs who are in the final phase of their life. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  19. Indications for implantable cardioverter-defibrillators based on evidence and judgment.

    Science.gov (United States)

    Myerburg, Robert J; Reddy, Vivek; Castellanos, Agustin

    2009-08-25

    Implantable cardioverter-defibrillators (ICDs) are generally reliable medical devices that have the potential to add quality years of life for appropriate candidates. Indications for ICDs have emerged from a series of randomized clinical trials, observational data from cohorts of high-risk patients with less common diseases, and expert opinion based on limited data in uncommon disorders. The randomized trials are limited by inadequate stratification designs that resulted from insufficient funding availability. The result was outcomes that led to uneven applications, based in part on post-implant experience of device utilization. In this document, we explore the basis for the features of the evidence available to support ICD use, the role of clinical judgment in circumstances in which data are limited or lacking, and the need for additional research to improve the specificity of indications. Directions for new research initiatives are considered. In addition, a general overview of a clinical research paradigm is presented, in which the research and health care delivery arms of the health care enterprise combine in research design and funding, as the latter bears the impact of the outcomes of the former. Impact estimates during the design of trials, considering reasonable contingencies for outcomes, are suggested as a means of justifying the size, scope, and appropriate costs of studies. If we who are involved in clinical research and health care delivery do not resolve this problem, for both ICDs and other new therapies that appear in the future, society will do it for us.

  20. Psychological effects of implantable cardioverter defibrillator shocks. A review of study methods

    Science.gov (United States)

    Manzoni, Gian Mauro; Castelnuovo, Gianluca; Compare, Angelo; Pagnini, Francesco; Essebag, Vidal; Proietti, Riccardo

    2015-01-01

    Background: The implantable cardioverter defibrillator (ICD) saves lives but clinical experience suggests that it may have detrimental effects on mental health. The ICD shock has been largely blamed as the main offender but empirical evidence is not consistent, perhaps because of methodological differences across studies. Objective: To appraise methodologies of studies that assessed the psychological effects of ICD shock and explore associations between methods and results. Data Sources: A comprehensive search of English articles that were published between 1980 and 30 June 2013 was applied to the following electronic databases: PubMed, EMBASE, NHS HTA database, PsycINFO, Sciencedirect and CINAHL. Review Methods: Only studies testing the effects of ICD shock on psychological and quality of life outcomes were included. Data were extracted according to a PICOS pre-defined sheet including methods and study quality indicators. Results: Fifty-four observational studies and six randomized controlled trials met the inclusion criteria. Multiple differences in methods that were used to test the psychological effects of ICD shock were found across them. No significant association with results was observed. Conclusions: Methodological heterogeneity of study methods is too wide and limits any quantitative attempt to account for the mixed findings. Well-built and standardized research is urgently needed. PMID:25698991

  1. Arrhythmia detection in single- and dual-chamber implantable cardioverter defibrillators: the more leads, the better?

    Science.gov (United States)

    Francia, Pietro; Balla, Cristina; Uccellini, Arianna; Cappato, Riccardo

    2009-09-01

    The implantable cardioverter defibrillator (ICD) offers life-saving therapies for primary and secondary prevention of sudden cardiac death in high-risk patients. However, ICD detection algorithms consistently misclassify a substantial proportion of supraventricular rhythms, thus carrying the risk for inappropriate therapies. Although single-chamber ICD (Sc-ICD) discrimination tools have been reported to provide high specificity in rejecting sinus tachycardia and atrial fibrillation with a relatively low ventricular rate, accurate recognition of atrial fibrillation with faster ventricular rates, atrial tachycardias, atrial flutter, and some reentrant tachycardias is still an issue. Dual-chamber ICDs (Dc-ICDs) are supposed to overcome specificity issues by enhancing detection algorithms with information derived from the atrial and ventricular timing relationship. The initial promise of Dc-ICDs was to improve detection specificity without compromising sensitivity, and to translate this advantage over Sc-ICDs in a more selective use of aggressive therapies. Despite this solid background, superiority of Dc- over Sc-ICDs has never been convincingly demonstrated. The present review focuses on the efficacy of contemporary ICD arrhythmia discrimination tools and appraises the so far reported evidence supporting the superiority of Dc-ICDs in preventing inappropriate therapies.

  2. Long-term mortality risk in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Theuns, Dominic A M J; Pedersen, Susanne S.

    2014-01-01

    risk in first-time ICD patients, adjusting also for measures of emotional distress. METHODS: Resting heart rate and QRS duration were assessed prior to ICD implantation in 448 patients. Primary study endpoint was all-cause mortality (up to 6.0 year follow-up, median follow-up of 5.6 years (IQR: 1......BACKGROUND: A paucity of studies has investigated the role of autonomic cardiac regulation as well as cardiac conduction in relation to prognosis in implantable cardioverter-defibrillator (ICD) patients. Therefore, we examined the association of heart rate and QRS duration with long-term mortality.......9)). The impact of heart rate and QRS duration on time to all-cause mortality was separately assessed with Cox proportional hazard regression analysis, adjusting for clinical factors and symptoms of depression and anxiety. RESULTS: Mean (SD) heart rate was 68.0 ± 13.3 bpm and mean QRS duration was 130.9 ± 36.9 ms...

  3. Interference of cardiac pacemaker and implantable cardioverter-defibrillator activity during electronic dental device use.

    Science.gov (United States)

    Roedig, Jason J; Shah, Jignesh; Elayi, Claude Samy; Miller, Craig S

    2010-05-01

    The authors conducted a study to determine if electromagnetic interference of cardiac pacemaker and implantable cardioverter-defibrillator (ICD) activity occurs during the operation of electronic dental devices. The authors tested nine electronic dental devices in vitro to assess their ability to interfere with the function of two pacemakers and two ICDs as determined by electrocardiographic telemetry. The pacing activity of both pacemakers and the dual-chamber ICD were inhibited during operation of the battery-operated composite curing light at between 2 and 10 centimeters from the generator or leads. The use of the ultrasonic scaler interfered with the pacing activity of the dual-chamber pacemaker at between 17 and 23 cm from the generator or leads, the single-chamber pacemaker at 15 cm from the generator or leads and both ICDs at 7 cm from the leads. The operation of the ultrasonic cleaning system interfered with the activity of the dual-chamber pacemaker at between 15 and 23 cm from the generator or leads, and of the single-chamber pacemaker at 12 cm. Operation of the electric toothbrush, electrosurgical unit, electric pulp tester, high- and low-speed handpieces, and an amalgamator did not alter pacing function. Select electronic dental devices interfere with pacemakers' and ICDs' sensing and pacing activity in vitro. Use of the ultrasonic scaler, ultrasonic cleaning system and battery-operated composite curing light may produce deleterious effects in patients who have pacemakers or ICDs.

  4. Cognitive behavioral therapy (CBT) in a Patient with Implantable Cardioverter Defibrillator (ICD) and Posttraumatic stress disorder(PTSD).

    Science.gov (United States)

    Ansari, Sahar; Arbabi, Mohammad

    2014-07-01

    The implantable cardioverter defibrillator (ICD) has currently become the standard treatment for preventing sudden cardiac death. There are some psychological consequences in patients with ICD such as posttraumatic stress disorder (PTSD) after the shocks induced by ICD. This report aimed to present the case of a 54-year-old man with ICD who had developed PTSD; his PTSD was treated, using cognitive-behavioral psychotherapy consisting of relaxation, mindfulness and problem solving techniques. In patients with ICD who are experiencing PTSD using cognitive behavioral interventions may be helpful to reduce their psychological sufferings.

  5. Cognitive behavioral therapy (CBT in a Patient with Implantable Cardioverter Defibrillator (ICD and Posttraumatic stress disorder(PTSD.

    Directory of Open Access Journals (Sweden)

    Sahar Ansari

    2014-09-01

    Full Text Available The implantable cardioverter defibrillator (ICD has currently become the standard treatment for preventing sudden cardiac death. There are some psychological consequences in patients with ICD such as posttraumatic stress disorder (PTSD after the shocks induced by ICD. This report aimed to present the case of a 54-year-old man with ICD who had developed PTSD; his PTSD was treated, using cognitive-behavioral psychotherapy consisting of relaxation, mindfulness and problem solving techniques. In patients with ICD who are experiencing PTSD using cognitive behavioral interventions may be helpful to reduce their psychological sufferings.

  6. Risk of pacemaker or implantable cardioverter defibrillator after radiotherapy for early-stage breast cancer in Denmark, 1982-2005

    DEFF Research Database (Denmark)

    Rehammar, Jens Christian; Johansen, Jens Brock; Jensen, Maj-Britt

    2017-01-01

    BACKGROUND AND PURPOSE: To examine the risk of cardiac conduction abnormalities or severe ventricular arrhythmias requiring implantation of a cardiac implantable electronic device (CIED), either a pacemaker or an implantable cardioverter-defibrillator, subsequent to breast cancer (BC) radiotherapy...... (RT). MATERIAL AND METHODS: All women treated for early-stage BC in Denmark from 1982 to 2005 were identified from the Danish Breast Cancer Cooperative Group. By record linkage to the Danish Pacemaker and ICD Registry information was retrieved on CIED implants subsequent to RT. Standardized incidence...

  7. Single lead catheter of implantable cardioverter-defibrillator with floating atrial sensing dipole implanted via persistent left superior vena cava.

    Science.gov (United States)

    Malagù, Michele; Toselli, Tiziano; Bertini, Matteo

    2016-04-26

    Persistent left superior vena cava (LSVC) is a congenital anomaly with 0.3%-1% prevalence in the general population. It is usually asymptomatic but in case of transvenous lead positioning, i.e., for pacemaker or implantable cardioverter defibrillator (ICD), may be a cause for significant complications or unsuccessful implantation. Single lead ICD with atrial sensing dipole (ICD DX) is a safe and functional technology in patients without congenital abnormalities. We provide a review of the literature and a case report of successful implantation of an ICD DX in a patient with LSVC and its efficacy in treating ventricular arrhythmias.

  8. Age and Outcomes of Primary Prevention Implantable Cardioverter Defibrillators in Patients with Non-Ischemic Systolic Heart Failure

    DEFF Research Database (Denmark)

    Elming, Marie Bayer; Nielsen, Jens C; Haarbo, Jens

    2017-01-01

    Background -The Danish Study to Assess the Efficacy of Implantable Cardioverter Defibrillators (ICD) in Patients with Non-ischemic Systolic Heart Failure on Mortality (DANISH) did not demonstrate an overall effect on all-cause mortality with ICD implantation. However, the pre-specified subgroup...... investigation. Methods -All 1116 patients from the DANISH study were included in this pre-specified subgroup analysis. We assessed the relationship between the ICD and mortality by age, and an optimal age cut-off was estimated non-parametrically using selection impact curves. Modes of death were divided...

  9. Rationale and design of the PRAETORIAN trial: A Prospective, RAndomizEd comparison of subcuTaneOus and tRansvenous ImplANtable cardioverter- defibrillator therapy

    OpenAIRE

    Olde Nordkamp, Louise R.A.; Knops, Reinoud; Bardy, Gust; Blaauw, Yuri; Boersma, Lucas; Bos, Johannes; Delnoy, Peter Paul; Pascal, P.F.H.M.; Driessen, Antoine; Groot, Joris; Herrman, J.P.R.; Jordaens, Luc; Kooiman, Kirsten; Maass, Alexander; Meine, Mathias

    2012-01-01

    textabstractBackground: Implantable cardioverter-defibrillators (ICDs) are widely used to prevent fatal outcomes associated with life-threatening arrhythmic episodes in a variety of cardiac diseases. These ICDs rely on transvenous leads for cardiac sensing and defibrillation. A new entirely subcutaneous ICD overcomes problems associated with transvenous leads. However, the role of the subcutaneous ICD as an adjunctive or primary therapy in patients at risk for sudden cardiac death is unclear....

  10. Longitudinal changes in intracardiac repolarization lability in patients with implantable cardioverter-defibrillator

    Directory of Open Access Journals (Sweden)

    Abhilash eGuduru

    2013-08-01

    Full Text Available Background─While it is known that elevated baseline intracardiac repolarization lability is associated with the risk of fast ventricular tachycardia (FVT /ventricular fibrillation (VF, the effect of its longitudinal changes on the risk of FVT/VF is unknown. Methods and Results─Near-field (NF right ventricular (RV intracardiac electrograms (EGMs were recorded every 3-6 months at rest in 248 patients with structural heart disease (mean age 61.2±13.3; 185[75%] male; 162[65.3%] ischemic cardiomyopathy and implanted cardioverter-defibrillator (ICD or cardiac resynchronization therapy defibrillator (CRT-D [201 (81% primary prevention]. Intracardiac beat-to-beat QT variability index (QTVINF was measured on NF RV EGM. During the first study phase (median 18 months, participants made on average 2.4 visits. Then remote follow-up was continued for an additional median period of 3 years. Average QTVINF did not change during the first year after ICD implantation (-0.342±0.603 at baseline vs. -0.262±0.552 at 6 months vs. -0.334±0.603 at 12 months; however, it decreased thereafter (-0.510±0.603 at 18 months; P=0.042. Adjusted population-averaged GEE model showed that the odds of developing FVT/VF increased by 75% for each 1 unit increase in QTVINF. (OR 1.75 [95%CI 1.05-2.92]; P=0.031. However, individual patient–specific QTVINF trends (increasing, decreasing, flat varied from patient to patient. For a given patient, the odds of developing FVT/VF were not associated with increasing or decreasing QTVINF over time (OR 1.27; [95%CI 0.05–30.10]; P = 0.881.Conclusion─While on average the odds of FVT/VF increased with an increase in QTVINF, patient-specific longitudinal trends in QTVINF did not affect the odds of FVT/VF.

  11. Depression and Associated Factors in Patients with Implantable Cardioverter-Defibrillators

    Directory of Open Access Journals (Sweden)

    Maryam Moshkani Farahani

    2017-01-01

    Full Text Available  Background: Psychological problems such as depression constitute a dilemma that patients with the implantable cardioverter-defibrillator (ICD usually encounter and may impact their quality of life. The purpose of this study was to evaluate the prevalence of depression among adults with the ICD and the relationship between depression and associated factors.   Methods: Totally, 115 individuals with the ICD participated in this cross-sectional study in Tehran, Iran, and depression and other related risk factors were evaluated in them. Two questionnaires, one for demographic characteristics and the Beck Depression Inventory, were applied for data acquisition. The data were analyzed, and the factors associated with depression in the patients with the ICD were assessed.    Results: The mean age of the study population was 59.85 ± 11.46 years. Males comprised 88 (76.5% and females 27 (23.5% of the patients. The multivariate analysis on the 115 patients revealed that frequency of ICD shocks (OR = 1.08, 95%CI: 1.02 - 1.10, male sex (OR = 2.28, 95%CI: 1.027 - 5.07, more hospital admissions (OR = 1.19, 95%CI: 1.11 - 1.25, smoking cessation (OR = 9.8, 95%CI: 4.48 - 20.07, presence of ICD shocks (OR = 4.5, 95%CI: 2.45 - 7.38, dyslipidemia (OR = 2.8, 95%CI: 1.22 - 4.95, and family history of depression (OR = 6.4, 95%CI: 3.0 - 13.46 were significantly and independently associated with the Beck score classifications.    Conclusion: These findings suggest that a poor psychosocial outcome in patients with the ICD may occur as a result of a variety of associated factors, most of which are predictable and preventable. 

  12. Sustaining cyborgs: sensing and tuning agencies of pacemakers and implantable cardioverter defibrillators.

    Science.gov (United States)

    Oudshoorn, Nelly

    2015-02-01

    Recently there has been a renewed interest in cyborgs, and particularly in new and emerging fusions of humans and technologies related to the development of human enhancement technologies. These studies reflect a trend to follow new and emerging technologies. In this article, I argue that it is important to study 'older' and more familiar cyborgs as well. Studying 'the old' is important because it enables us to recognize hybrids' embodied experiences. This article addresses two of these older hybrids: pacemakers and implantable cardioverter defibrillators inserted in the bodies of people suffering from heart-rhythm disturbances. My concern with hybrid bodies is that internal devices seem to present a complex and neglected case if we wish to understand human agency. Their 'users' seem to be passive because they cannot exert any direct control over the working of their devices. Technologies inside bodies challenge a longstanding tradition of theorizing human-technology relations only in terms of technologies external to the body. Cyborg theory is problematic as well because most studies tend to conceptualize the cyborg merely as a discursive entity and silence the voices of people living as cyborgs. Inspired by feminist research that foregrounds the materiality of the lived and intimate relations between bodies and technologies, I argue that creating these intimate relations requires patients' active involvement in sustaining their hybrid bodies. Based on observations of these monitoring practices in a Dutch hospital and interviews with patients and technicians, the article shows that heart cyborgs are far from passive. On the contrary, their unique experience in sensing the entangled agencies of technologies and their own heart plays a crucial role in sustaining their hybrid bodies.

  13. Experiences of Young Adults With Pacemakers and/or Implantable Cardioverter Defibrillators.

    Science.gov (United States)

    Larimer, Karen; Durmus, Julie; Florez, Elizabeth

    The number of implanted devices (pacemakers [PMs] and implantable cardioverter defibrillators [ICDs]) is increasing. Because of technological advances, these devices are used in greater numbers in children and adolescents. Challenges of having these devices have been well studied in adults, but little is known about the lived experiences from the perspective of young adults. This study explored the lived experiences, coping behaviors, and challenges of young adults who had cardiac devices implanted during childhood. A descriptive qualitative study design was used. Purposive sampling was used to identify young adults aged 18 to 29 years, living with a PM and/or ICD. Participants were interviewed about their experiences and challenges related to living with a PM or ICD, with common themes identified and analyzed. A total of 6 participants were interviewed for this study. The challenges of living with a PM and/or ICD included insecurity about physical appearance, device compliance, physical sensations of the device, future uncertainty, and limited support. The identified coping behaviors utilized by the participants were confrontation, acceptance, educating others, spreading awareness, avoidance, and humor. The overall lived experiences described were appreciation for device benefits, fear of device malfunction, and attracting attention. The lived experiences of young recipients often mirror that of older adults; however, it is clear that there are challenges and coping behaviors unique to young adults living with a PM and/or ICD. It is important to educate healthcare providers about the unique challenges that young adults may face so they can provide the appropriate support to this population.

  14. Use of Guideline-Directed Medications for Heart Failure Before Cardioverter-Defibrillator Implantation.

    Science.gov (United States)

    Roth, Gregory A; Poole, Jeanne E; Zaha, Rebecca; Zhou, Weiping; Skinner, Jonathan; Morden, Nancy E

    2016-03-08

    Guideline-directed medical therapy (GDMT) for heart failure with reduced ejection fraction (HFrEF) is recommended before primary prevention implantable cardioverter-defibrillator (ICD) placement. Adherence to this recommendation and associated outcomes are unknown. This study examined the use of GDMT (≥1 prescription filled for both a renin-angiotensin inhibitor [RAI] and a heart failure-approved beta-blocker [HFBB]) within 90 days before primary prevention ICD placement in patients with HFrEF. Data from the National Cardiovascular Data Registry ICD Registry were merged with a 40% random sample of Medicare administrative data. Prescription fills for recipients of primary prevention ICD between 2007 and 2011 were examined, analyzing GDMT overall and for each U.S. hospital referral region. We identified characteristics associated with GDMT and the association with 1-year mortality. Among 19,733 patients with HFrEF and primary prevention ICD, 61.1% filled any GDMT before implantation. Across hospital referral regions, GDMT was applied in 51% to 71%. The strongest predictors of any GDMT included absence of chronic renal disease or nonsustained ventricular tachycardia, low-income prescription benefits subsidy, and less recent left ventricular ejection fraction evaluation. Patients receiving GDMT versus those without had a lower 1-year mortality rate after ICD implantation (11.1% vs. 16.2%), even after adjustment for comorbidities, left ventricular ejection fraction, and functional heart failure class. Rates of GDMT for HFrEF before primary prevention ICD implantation were low, and failure to achieve GDMT was associated with significantly decreased 1-year survival. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  15. Performance of a radiation protection cabin during implantation of pacemakers or cardioverter defibrillators.

    Science.gov (United States)

    Ploux, Sylvain; Ritter, Philippe; Haïssaguerre, Michel; Clementy, Jacques; Bordachar, Pierre

    2010-04-01

    Pacemaker implants are associated with a high cumulative exposure of the operators to radiation. Standard radiation protection with lead aprons is incomplete and the cause of spine disorders. A radiation protection cabin offers complete protection by surrounding the operator, without requiring a lead apron. We randomly and evenly assigned 60 patients undergoing implantations of permanent pacemakers or cardioverter defibrillators (ICD) with (a) a radiation protection cabin (cabin group, n = 30) versus (b) standard protection with a 0.5 mm lead-equivalent apron (control group, n = 30). Radiation exposure was measured using personal electronic dosimeters placed on the thorax, back, and head of the operator. The patient, procedural, and device characteristics of the 2 study groups were similar. All procedures in the cabin group were performed as planned without increase in duration or complication rate compared with the control group. The mean radiation dose to the head, normalized for fluoroscopy duration, was significantly lower in the cabin (0.040 +/- 0.032 microSv/min) than in the control (1.138 +/- 0.560 microSv/min) group (p < 0.0001). The radiation doses to the thorax (0.043 +/- 0.027 vs 0.041 +/- 0.040 microSv/min) and back (0.038 +/- 0.029 vs 0.033 +/- 0.018 microSv/min) in the cabin versus control group (under the apron) were similar. The use of a radiation protection cabin markedly decreased the exposure of the operator to radiation, and eliminated the need to wear a lead apron, without increasing the procedural time or complication rate during implantation of pacemaker and ICD.

  16. Investigation of the Utility of the Audible Alert in Recent Generation Medtronic Implantable Cardioverter Defibrillators.

    Science.gov (United States)

    Manandhar, Meryna; Nemirovsky, Dmitry; Feigenblum, David Y; Simons, Grant R

    2016-12-01

    Medtronic implantable cardioverter defibrillators (ICDs; Medtronic Inc., Mounds View, MN, USA) are equipped with Patient Alert™, a feature in which the ICD generator emits a series of audible tones to notify patients of possible system malfunction. A prior study of this issue revealed that only 50% of patients with older Medtronic devices were able to hear alerts. More recently, Medtronic has incorporated modifications to the alert. Therefore, we studied how frequently alert tones emitted by the current generation of Medtronic ICDs are audible by patients. A series of patients were evaluated in an outpatient ICD clinic. Alert tones were demonstrated using a device programmer in a quiet room and in the presence of low-level background noise. Patients reported whether they heard the tones, and they completed questionnaires regarding the tones. The total sample size was 100 patients, 81 male, who ranged from 29 years to 94 years of age (mean age 72.1 ± 11.8). Among the study subjects, 46% were older than 75 years, 41% were between 55 years and 75 years, and 13% were younger than 55 years. In the absence of background noise, 94% of patients were able to hear both alerts, 1% heard only one alert, and 5% heard neither. In the presence of background noise, 88% of patients heard both the alerts, 7% heard only one alert, and 5% heard neither alerts. Our results demonstrate that alert tones in recent generation Medtronic ICDs have improved audibility, compared to prior published data, among a large outpatient ICD population. © 2016 Wiley Periodicals, Inc.

  17. Current Indications for Implantable Cardioverter Defibrillators in Non-Ischemic Cardiomyopathies and Channelopathies.

    Science.gov (United States)

    González-Torrecilla, Esteban; Arenal, Angel; Atienza, Felipe; Datino, Tomás; Bravo, Loreto; Ruiz, Pablo; Ávila, Pablo; Fernández-Avilés, Francisco

    2015-01-01

    Current indications for implantable cardioverter defibrillators (ICDs) in patients with channelopathies and cardiomyopathies of non-ischemic origin are mainly based on non-randomized evidence. In patients with nonischemic dilated cardiomyopathy (NIDCM), there is a tendency towards a beneficial effect on total mortality of ICD therapy in patients with significant left ventricular (LV) dysfunction. Although an important reduction in sudden cardiac death (SCD) seems to be clearly demonstrated in these patients, a net beneficial effect on total mortality is unclear mostly in cases with good functional status. Risk stratification has been changing over the last two decades in patients with hypertrophic cardiomyopathy (HCM). Its risk profile has been delineated in parallel with the beneficial effect of ICD in high risk patients. Observational results based on "appropriate" ICD interventions do support its usefulness both in primary and secondary SCD prevention in these patients. Novel risk models quantify the rate of sudden cardiac death in these patients on individual basis. Less clear risk stratification is available for cases of arrhythmogenic right ventricular cardiomyopathy (ARVC) and in other uncommon familiar cardiomyopathies. Main features of risk stratification vary among the different channelopathies (long QT syndrome -LQTS-, Brugada syndrome, etc) with great debate on the management of asymptomatic patients. For most familiar cardiomyopathies, ICD therapy is the only accepted strategy in the prevention of SCD. So far, genetic testing has a limited role in risk evaluation and management of the individual patient. This review aims to summarize these criticisms and to refine the current indications of ICD implantation in patients with cardiomyopathies and major channelopathies.

  18. Beta-blocker therapy is not associated with symptoms of depression and anxiety in patients receiving an implantable cardioverter-defibrillator

    NARCIS (Netherlands)

    M.T. Hoogwegt (Madelein); N. Kupper (Nina); D.A.M.J. Theuns (Dominic); L.J.L.M. Jordaens (Luc); S.S. Pedersen (Susanne)

    2012-01-01

    textabstractBeta-blockers are frequently prescribed to implantable cardioverter-defibrillator (ICD) patients. Beta-blocker therapy has been proposed to induce emotional distress such as depression and anxiety, but a paucity of studies has examined the relationship between beta-blockers and distress.

  19. Comorbidity burden is associated with poor psychological well-being and physical health status in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Kupper, Nina; Jordaens, Luc;

    2013-01-01

    Comorbidity burden has been linked to survival in patients with an implantable cardioverter-defibrillator (ICD), but no study has examined the influence on psychological well-being and health status. We examined the relationship between comorbidity burden and anxiety, depression, and health status...

  20. Pre-clinical detection of amiodarone-induced acute fibrosing alveolitis by intra-thoracic impedance monitor of an implantable cardioverter-defibrillator.

    Science.gov (United States)

    Hsieh, Yu-Cheng; Huang, Jin-Long; Chin, Chun-Shih; Lin, Tung-Chao; Liao, Ying-Chieh; Ting, Chih-Tai; Wu, Tsu-Juey

    2011-01-01

    A 66-year-old male received an implant of a dual-chamber implantable cardioverter-defibrillator (ICD) and was prescribed amiodarone (400 mg/day). The intra-thoracic impedance monitor in the ICD antecedently detected amiodarone-induced acute fibrosing alveolitis >3 months prior to clinical symptoms.

  1. The distressed (Type D) personality in both patients and partners enhances the risk of emotional distress in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    van den Broek, Krista C; Versteeg, Henneke; Erdman, Ruud A M

    2011-01-01

    A subgroup of patients with an implantable cardioverter defibrillator (ICD) experiences emotional distress. This may be related to partner factors. We examined the impact of the personality of the partner (i.e., the distressed (Type D) personality) in combination with that of the patient on anxiety...

  2. Serum-Based Oxylipins Are Associated with Outcomes in Primary Prevention Implantable Cardioverter Defibrillator Patients

    Science.gov (United States)

    Zhang, Yiyi; Guallar, Eliseo; Blasco-Colmenares, Elena; Harms, Amy C.; Vreeken, Rob J.; Hankemeier, Thomas; Tomaselli, Gordon F.; Cheng, Alan

    2016-01-01

    Introduction Individuals with systolic heart failure are at risk of ventricular arrhythmias and all-cause mortality. Little is known regarding the mechanisms underlying these events. We sought to better understand if oxylipins, a diverse class of lipid metabolites derived from the oxidation of polyunsaturated fatty acids, were associated with these outcomes in recipients of primary prevention implantable cardioverter defibrillators (ICDs). Methods Among 479 individuals from the PROSE-ICD study, baseline serum were analyzed and quantitatively profiled for 35 known biologically relevant oxylipin metabolites. Associations with ICD shocks for ventricular arrhythmias and all-cause mortality were evaluated using Cox proportional hazards models. Results Six oxylipins, 17,18-DiHETE (HR = 0.83, 95% CI 0.70 to 0.99 per SD change in oxylipin level), 19,20-DiHDPA (HR = 0.79, 95% CI 0.63 to 0.98), 5,6-DiHETrE (HR = 0.73, 95% CI 0.58 to 0.91), 8,9-DiHETrE (HR = 0.76, 95% CI 0.62 to 0.95), 9,10-DiHOME (HR = 0.81, 95% CI 0.65 to 1.00), and PGF1α (HR = 1.33, 95% CI 1.04 to 1.71) were associated with the risk of appropriate ICD shock after multivariate adjustment for clinical factors. Additionally, 4 oxylipin-to-precursor ratios, 15S-HEPE / FA (20:5-ω3), 17,18-DiHETE / FA (20:5-ω3), 19,20-DiHDPA / FA (20:5-ω3), and 5S-HEPE / FA (20:5-ω3) were positively associated with the risk of all-cause mortality. Conclusion In a prospective cohort of patients with primary prevention ICDs, we identified several novel oxylipin markers that were associated with appropriate shock and mortality using metabolic profiling techniques. These findings may provide new insight into the potential biologic pathways leading to adverse events in this patient population. PMID:27281224

  3. [Chronic transvenous pacemaker/implantable cardioverter defibrillator leads implantation induced pathological changes].

    Science.gov (United States)

    Li, Yanhui; Dykoski, Richard; Li, Jianming

    2015-05-01

    Widely pacemaker/implantable cardioverter defibrillator (ICD) implantation is also related to an increasing need for transvenous lead extraction. Understanding the location and extent of pathological changes, including adhesions and fibrous tissue formation along the course of chronic pacemaker/ICD leads, are essential for operators performing lead extraction operations in order to reduce the potential life threatening complications. Three parts are included in the research, pathological examination on 83 extracted pacemaker/ICD leads using excimer laser technique from March 2008 to March 2011, autopsy examination of one died patient during lead extraction for lead-related infective endocarditis, and anatomical analysis on pacemaker/ICD leads from 10 patients died of other non-cardiac causes. Extensive encapsulated fibrous tissue around the leads and extensive adhesion/fibrosis along the course of the leads from venous entry site to the lead/myocardial interface could be detected on transvenous pacemaker/ICD leads. Since the tissue at the junction between superior vena cava (SVC) and right atrium (RA) is very thin, free of pericardium, thus, this is a common place for extensive adhesion/fibrosis and myocardial perforation/tear during lead extraction, which accounted for one death during extraction in our cohort. Extensive adhesion and fibrosis were also observed at the tricuspid valve and subvalvular structures. Leads implanted to the right ventricular apex were close to the epicardial surface and prone to perforation through myocardium. It is common to observe thrombus on the leads or at the interface between leads and myocardial tissue, especially at right atrial appendage (RAA) at the site of lead insertion. Extensive adhesions and fibrosis can be commonly seen along the course of pacemaker/ICD leads, and at SVC to RA junction, the tricuspid valve/subvalvular structures, and RA/RV lead interface. The tissue at SVC to RA junction is very thin, making it

  4. Failure of implantable cardioverter-defibrillator leads: a matter of lead size?

    Science.gov (United States)

    Rordorf, Roberto; Poggio, Luca; Savastano, Simone; Vicentini, Alessandro; Petracci, Barbara; Chieffo, Enrico; Klersy, Catherine; Landolina, Maurizio

    2013-02-01

    Small-diameter implantable cardioverter-defibrillator (ICD) Sprint Fidelis and Riata leads have been recalled owing to an increased risk of lead failure, thus arousing the suspicion that lead size might be a critical issue. To compare the incidence of failure of small-diameter (≤8 F) and standard-diameter (>8 F) ICD leads implanted in a single center. From January 2003 to December 2010, 190 Sprint Fidelis, 182 Riata/Riata ST, 99 Optim (Riata Optim/Durata), and 419 standard-diameter leads were implanted in our center. During a median follow-up of 33 months, the overall failure rate was 6.3%. Follow-up duration was similar for Sprint Fidelis, Riata, and standard-diameter leads but shorter for the Optim group. The failure rate was significantly higher in Sprint Fidelis leads than in both standard-diameter (4.8%/year vs 0.8%/year; P<.001) and Riata/Riata ST (4.8%/year vs 2.6%/year; P = .03) leads. The incidence of lead failure in Riata/Riata ST leads proved significantly higher than in standard-diameter leads (2.6%/year vs 0.8%/year; P = .001). No cases of lead failure were recorded in the Optim group. On multivariable analyses, small-diameter (hazard ratio [HR] 5.03, 2.53-10.01, P<.001), Sprint Fidelis (HR 6.3, 3.1-13.3, P<.001), or Riata/Riata ST (HR 4.5, 1.9-10.5, P = .001) leads and age<60 years (HR 2.3, 1.3-4.3, P = .005) were found to independently increase the risk of lead failure. Compared with standard-diameter leads, both Sprint Fidelis and Riata/Riata ST small-diameter ICD leads are at an increased risk of failure, although the incidence of events is significantly lower in the Riata than in the Sprint Fidelis group. Copyright © 2013 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  5. Implantable cardioverter defibrillator therapy in young patients with cardiomyopathies and channelopathies: a single Italian centre experience.

    Science.gov (United States)

    Migliore, Federico; Silvano, Maria; Zorzi, Alessandro; Bertaglia, Emanuele; Siciliano, Mariachiara; Leoni, Loira; De Franceschi, Pietro; Iliceto, Sabino; Corrado, Domenico

    2016-07-01

    This study was designed to prospectively evaluate the risk-benefit ratio of implantable cardioverter defibrillator (ICD) therapy in young patients with cardiomyopathies and channelopathies. The study population included 96 consecutive patients [68 men, median age 27 (22-32) years] with cardiomyopathies, such as arrhythmogenic right ventricular cardiomyopathy (n = 35), dilated cardiomyopathy (n = 17), hypertrophic cardiomyopathy (n = 15), Brugada syndrome (n = 14), idiopathic ventricular fibrillation (n = 5), left ventricular noncompaction (n = 4), long-QT syndrome (n = 4) and short-QT syndrome (n = 2), who were 18-35 years old at the time of ICD implantation. During a mean follow-up of 72.6 ± 53.3 months, one patient with end-stage hypertrophic cardiomyopathy died because of acute heart failure, and 11 patients underwent orthotopic heart transplantation. Twenty patients (20.8%) had a total of 38 appropriate ICD interventions (4%/year), and 26 patients (27.1%) experienced a total of 49 adverse ICD-related events (5.4%/year), including 23 inappropriate ICD interventions occurring in nine patients (9.4%) and 26 device-related complications requiring surgical revision occurring in 20 patients (20.8%). Lead failure/fracture requiring lead extraction was the most common complication (n = 9). A threshold for ICD therapy less than 300 ms was associated with a borderline significant lower probability of inappropriate ICD interventions (hazard ratio = 0.2; 95% confidence interval 0.02-1.2; P = 0.07), whereas underweight status was an independent predictor of device-related complications (hazard ratio = 5.4; 95% confidence interval 1.5-19.4; P = 0.01). In young patients with cardiomyopathies and channelopathies, ICD therapy provided life-saving protection by effectively terminating life-threatening ventricular arrhythmias. However, because ICD-related adverse events are common, the risk/benefit ratio should be

  6. Outcomes in African-Americans Undergoing Cardioverter Defibrillators Implantation for Primary Prevention of Sudden Cardiac Death: Findings from The Prospective Observational Study of Implantable Cardioverter-Defibrillators (PROSE-ICD)

    Science.gov (United States)

    Zhang, Yiyi; Kennedy, Robert; Blasco-Colmenares, Elena; Butcher, Barbara; Norgard, Sanaz; Eldadah, Zayd; Dickfeld, Timm; Ellenbogen, Kenneth A.; Marine, Joseph E.; Guallar, Eliseo; Tomaselli, Gordon F.; Cheng, Alan

    2014-01-01

    Background Implantable cardioverter defibrillators (ICDs) reduce the risk of death in patients with left ventricular dysfunction. Little is known regarding the benefit of this therapy in African-Americans (AA). Objective To determine the association between African-American race and outcomes in a cohort of primary prevention cardioverter defibrillators (ICD) patients. Methods We conducted a prospective cohort study of patients with systolic heart failure who underwent ICD implantation for primary prevention of sudden cardiac death. The primary endpoint was appropriate ICD shock defined as a shock for rapid ventricular tachyarrhythmias. The secondary endpoint was all-cause mortality. Results There were 1,189 patients (447 AAs and 712 non-AAs) enrolled. Over a median follow-up of 5.1 years, a total of 137 patients experienced an appropriate ICD shock, and 343 died (294 of whom died without receiving an appropriate ICD shock). The multivariate adjusted hazard ratios (95% CI) comparing AAs vs. non-AAs were 1.24 (0.96 to 1.59) for all-cause mortality, 1.33 (1.02, 1.74) for all-cause mortality without receiving appropriate ICD shock, and 0.78 (0.51, 1.19) for appropriate ICD shock. Ejection fraction, diabetes, and hypertension appeared to explain 24.1% (10.1 to 69.5%), 18.7% (5.3 to 58.0%), and 13.6% (3.8 to 53.6%) of the excess risk of mortality in AAs, with a large proportion of the mortality difference remains unexplained. Conclusions In patients with primary prevention ICDs, AAs had an increased risk of dying without receiving an appropriate ICD shock compared to non-AAs. PMID:24793459

  7. Clinical Effects and Implications of Cardiac Rehabilitation for Implantable Cardioverter Defibrillator Patients: A Mixed-Methods Approach Embedding Data From the Copenhagen Outpatient ProgrammE-Implantable Cardioverter Defibrillator Randomized Clinical Trial With Qualitative Data.

    Science.gov (United States)

    Berg, Selina Kikkenborg; Moons, Philip; Christensen, Anne Vingaard; Zwisler, Ann-Dorthe; Pedersen, Birthe D; Pedersen, Preben Ulrich

    2015-01-01

    The Copenhagen Outpatient ProgrammE-Implantable Cardioverter Defibrillator trial was a randomized clinical trial that compared a complex rehabilitation intervention including exercise training and psychoeducational interventions with usual care. A significant difference between rehabilitation and usual care was found in physical capacity and general and mental health. However, the clinical effect sizes of these findings were not investigated, and the findings from the quantitative and qualitative analyses were not triangulated to address the issue of whether the qualitative results could help explain the quantitative results and bring forward additional information. The objectives are to (a) determine the clinical effect sizes of the primary outcomes and (b) triangulate the quantitative and qualitative findings. A total of 196 patients with first-time implantable cardioverter defibrillator implantation were randomized (1:1) to comprehensive cardiac rehabilitation (12 weeks of exercise training and 1 year of psychoeducational follow-up) versus treatment as usual. Two primary outcomes, perceived health (Short Form-36) and peak oxygen uptake, were used. Cohen d was calculated. Qualitative interviews were conducted with 10 patients representing the rehabilitation group. Triangulation was carried out by integrating the findings from the quantitative and qualitative results in light of each other. Clinically meaningful effects were found between groups in peak oxygen uptake, general health, and mental health in favor of the rehabilitation group. Within groups, we found medium/high effect sizes on the mental component score in the rehabilitation group over time and only a small effect in the usual care group. The mechanisms of these effects were further explained by the qualitative findings. Patients with better physical health learned how to interpret body signals and adjust exercise behavior and experienced increased physical capacity. Those with better mental health

  8. Impact of programming strategies aimed at reducing nonessential implantable cardioverter defibrillator therapies on mortality: a systematic review and meta-analysis.

    Science.gov (United States)

    Tan, Vern Hsen; Wilton, Stephen B; Kuriachan, Vikas; Sumner, Glen L; Exner, Derek V

    2014-02-01

    Patients who receive implantable cardioverter defibrillator therapies are at higher risk of death versus those who do not. Programmed settings to reduce nonessential implantable cardioverter defibrillator therapies (therapy reduction programming) have been developed but may have adverse effects. This systematic review and meta-analysis assessed the relationship between therapy reduction programming with the risks of death from any cause, implantable cardioverter defibrillator shocks, and syncope. MEDLINE, EMBASE, and clinicaltrials.gov databases were searched to identify relevant studies. Those that followed patients for ≥6 months and reported mortality were included. Six met the inclusion criteria; 4 randomized (Comparison of Empiric to Physician-Tailored Programming of ICDs [EMPIRIC], Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy [MADIT-RIT], Avoid Delivering Therapies for Non-sustained Arrhythmias in ICD Patients III [ADVANCE III], and Programming Implantable Cardioverter-Defibrillators in Patients with Primary Prevention Indication to Prolong Time to First Shock [PROVIDE]) and 2 prospective studies (Role of Long Detection Window Programming in Patients With Left Ventricular Dysfunction, Non-ischemic Etiology in Primary Prevention Treated with a Biventricular ICD [RELEVANT] and Primary Prevention Parameters Evaluation [PREPARE]). These 6 studies included 7687 (3598 conventional and 4089 therapy reduction programming) patients. Most (77%) participants were men, had a history of ischemic heart disease (56%), and were prescribed β-blockers (84%). Therapy reduction programming was associated with a 30% relative reduction in mortality (95% confidence interval, 16%-41%; Pprogramming (P=0.5). Therapy reduction programming results in a large, significant, and consistent reduction in mortality, with no apparent increase in the risk of syncope.

  9. Relation of symptomatic heart failure and psychological status to persistent depression in patients with implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Hoogwegt, Madelein T; Jordaens, Luc

    2011-01-01

    Association class III-IV (OR 2.95; 95% CI 1.47 to 5.89), Type D personality (OR 7.98; 95% CI 3.98 to 16.04), and the use of psychotropic medication (OR 2.73; 95% CI 1.27 to 5.84) were independent correlates of persistent depression. In conclusion, symptomatic heart failure, psychological status......Studies on psychological morbidity in patients with an implantable cardioverter-defibrillator (ICD) have focused on mean differences rather than intraindividual differences. Such an approach masks the chronicity of symptoms in individual patients and the potential differences in cardiac outcomes....... We examined the prevalence and correlates of persistent depression using an intraindividual approach. Consecutive patients who had undergone ICD implantation (n = 386; 79.3% men) completed a set of validated questionnaires, including the Hospital Anxiety and Depression Scale (HADS), at baseline and 3...

  10. Slow ventricular tachycardia in a 91-year-old man with implantable cardioverter-defibrillator and acute respiratory failure.

    Science.gov (United States)

    Vargas, Nicola; Tibullo, Loredana; Landi, Cesare A E; Carifi, Giovanni; Landi, Emanuela; Salsano, Elisa; Di Grezia, Francesco; Candelmo, Fiore

    2017-08-01

    Slow ventricular tachycardia (VT) in patients with devices such as an implantable cardioverter - defibrillator (ICD) is more common than in the rest of the population. The incidence in elderly patients with an ICD remains largely unknown. In younger patients, slow VT is generally asymptomatic or associated with limited clinical relevance. It may be efficiently and safely terminated by anti-tachycardia pacing. We present a case of slow VT in a 91-year-old man with ICD with type 1 acute respiratory failure and drowsiness. Very elderly patients who have poor cardiac reserve and minor deterioration in cardiac function can face serious consequences such as ventricular fibrillation, cardiac arrest, and sudden cardiac death. The persistent ventricular rhythm may have a deleterious effect on their haemodynamic status, with potential aggravation of symptoms of heart failure and further impairment of ventricular function. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Psychometric properties of HeartQoL, a core heart disease-specific health-related quality of life questionnaire, in Danish implantable cardioverter defibrillator recipients

    DEFF Research Database (Denmark)

    Zangger, Graziella; Zwisler, Ann-Dorthe; Kikkenborg Berg, Selina

    2017-01-01

    Background Patient-reported health-related quality of life is increasingly used as an outcome measure in clinical trials and as a performance measure to evaluate quality of care. The objective of this study was to assess the psychometric properties of the Danish HeartQoL questionnaire, a core heart...... psychometric attributes of validity and reliability in this implantable cardioverter defibrillator population. This study adds support for the HeartQoL as a core heart-specific health-related quality of life questionnaire in a broad group of patients with heart disease including implantable cardioverter...

  12. Shoulder joint dislocation as an unusual complication of defibrillation threshold testing following subcutaneous implantable cardioverter-defibrillator implantation.

    Science.gov (United States)

    Noheria, Amit; Cha, Yong-Mei; Asirvatham, Samuel J; Friedman, Paul A

    2014-01-01

    A 53-year-old man underwent implantation of a totally subcutaneous ICD (S-ICD; Boston Scientific). He was positioned supine, with the left arm abducted, externally rotated (i.e. palm up) and strapped to the arm extender. The generator was placed in the left mid-axillary line along the 5th-6th intercostal spaces and the defibrillation coil was tunneled anterior to the sternum. Defibrillation threshold (DFT) testing with 65 Jcaused a forceful pectoralis twitch. The patient woke up with a painful anteriorly dislocated left shoulder. Glenohumeral dislocation due to DFT testing has not been previously reported. It is likely that this complication is specific to the S-ICD implantation, and is related to positioning with the arm abducted, externally rotated, and immobilized, and use of greater defibrillation energy with current pathway through the bulk of the pectoralis muscle.Precautions may include extending the arm palm down, strapping the arm loosely, and adduction of the arm for DFT testing.

  13. Rationale and design of the PRAETORIAN trial : A Prospective, RAndomizEd comparison of subcuTaneOus and tRansvenous ImplANtable cardioverter-defibrillator therapy

    NARCIS (Netherlands)

    Nordkamp, Louise R. A. Olde; Knops, Reinoud E.; Bardy, Gust H.; Blaauw, Yuri; Boersma, Lucas V. A.; Bos, Johannes S.; Delnoy, Peter Paul H. M.; van Dessel, Pascal F. H. M.; Driessen, Antoine H. G.; de Groot, Joris R.; Herrman, Jean Paul R.; Jordaens, Luc J. L. M.; Kooiman, Kirsten M.; Maass, Alexander H.; Meine, Mathias; Mizusawa, Yuka; Molhoek, Sander G.; van Opstal, Jurjen; Tijssen, Jan G. P.; Wilde, Arthur A. M.

    2012-01-01

    Background Implantable cardioverter-defibrillators (ICDs) are widely used to prevent fatal outcomes associated with life-threatening arrhythmic episodes in a variety of cardiac diseases. These ICDs rely on transvenous leads for cardiac sensing and defibrillation. A new entirely subcutaneous ICD over

  14. Programming implantable cardioverter-defibrillators in primary prevention: higher or later.

    Science.gov (United States)

    Clementy, Nicolas; Pierre, Bertrand; Simeon, Edouard; Lallemand, Bénédicte; Fauchier, Laurent; Babuty, Dominique

    2014-05-01

    Defibrillator shocks, appropriate or not, are associated with significant morbidity, as they decrease quality of life, can be involved in depression and anxiety, and are known to be proarrhythmic. Most recent data have even shown an association between shocks and overall mortality. As opposed to other defibrillator-related complications, the rate of inappropriate and unnecessary shocks can (and should) be decreased with adequate programming. This review focuses on the different programming strategies and tips available to reduce the rate of shocks in primary prevention patients with left ventricular dysfunction implanted with a defibrillator, as well as some of the manufacturers' device specificities.

  15. Psychometric properties of HeartQoL, a core heart disease-specific health-related quality of life questionnaire, in Danish implantable cardioverter defibrillator recipients

    DEFF Research Database (Denmark)

    Zangger, Graziella; Zwisler, Ann-Dorthe; Kikkenborg Berg, Selina

    2017-01-01

    Background Patient-reported health-related quality of life is increasingly used as an outcome measure in clinical trials and as a performance measure to evaluate quality of care. The objective of this study was to assess the psychometric properties of the Danish HeartQoL questionnaire, a core heart...... disease-specific health-related quality of life questionnaire, in implantable cardioverter defibrillator recipients. Design This study involved cross-sectional and test-retest study designs. Method Implantable cardioverter defibrillator recipients in the cross-sectional study completed the Heart......QoL, the Short-Form 36 Health Survey, and the Hospital Anxiety and Depression Scale. The HeartQoL structure, construct-related validity (convergent and discriminative) and reliability (internal consistency) were assessed. HeartQoL reproducibility (test-retest) was assessed in an independent sample of implantable...

  16. Programmed Ventricular Stimulation to Risk Stratify for Early Cardioverter-Defibrillator Implantation to Prevent Tachyarrhythmias following Acute Myocardial Infarction (PROTECT-ICD): Trial Protocol, Background and Significance.

    Science.gov (United States)

    Zaman, Sarah; Taylor, Andrew J; Stiles, Martin; Chow, Clara; Kovoor, Pramesh

    2016-11-01

    The 'Programmed Ventricular Stimulation to Risk Stratify for Early Cardioverter-Defibrillator Implantation to Prevent Tachyarrhythmias following Acute Myocardial Infarction' (PROTECT-ICD) trial is an Australian-led multicentre randomised controlled trial targeting prevention of sudden cardiac death in patients who have at least moderately reduced cardiac function following a myocardial infarct (MI). The primary objective of the trial is to assess whether electrophysiological study to guide prophylactic implantation of an implantable cardioverter-defibrillator (ICD) early following MI (first 40 days) will lead to a significant reduction in sudden cardiac death and non-fatal arrhythmia. The secondary objective is to assess the utility of cardiac MRI (CMR) in assessing early myocardial characteristics, and its predictive value for both inducible ventricular tachycardia (VT) at EPS and SCD/ non-fatal arrhythmia at follow-up.

  17. A comparison of the health status and psychological distress of partners of patients with a left ventricular assist device versus an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Brouwers, Corline; Caliskan, Kadir; de Jonge, Nicolaas;

    2014-01-01

    OBJECTIVE: To examine if the caregiving for patients with a left ventricular assist device (LVAD) is related to a poorer health status and more distress compared to patients with an implantable cardioverter defibrillator (ICD). BACKGROUND: Partners distress may influence patient outcomes and is t......OBJECTIVE: To examine if the caregiving for patients with a left ventricular assist device (LVAD) is related to a poorer health status and more distress compared to patients with an implantable cardioverter defibrillator (ICD). BACKGROUND: Partners distress may influence patient outcomes...... (F = 10.71, p = .001) but poorer mental health status (F = 14.82, p compared to ICD partners (F = 3.68, p = .05) at 6 months follow-up, also in adjusted analyses. There was no significant difference between groups on anxiety. CONCLUSION: Caregivers of LVAD...... patients show higher distress levels compared to caregivers of ICD patients. LVAD partners may have a need for support beyond what is offered currently in clinical practice....

  18. Beta-blocker therapy is not associated with symptoms of depression and anxiety in patients receiving an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Kupper, Nina; Theuns, Dominic A M J

    2012-01-01

    Beta-blockers are frequently prescribed to implantable cardioverter-defibrillator (ICD) patients. Beta-blocker therapy has been proposed to induce emotional distress such as depression and anxiety, but a paucity of studies has examined the relationship between beta-blockers and distress. We...... investigated the association between beta-blocker therapy, including type and dosage, and symptoms of anxiety and depression in a consecutive cohort of patients receiving an ICD....

  19. Beta-blocker therapy is not associated with symptoms of depression and anxiety in patients receiving an implantable cardioverter-defibrillator

    OpenAIRE

    Hoogwegt, Madelein; Kupper, Nina; Theuns, Dominic; Jordaens, Luc; Pedersen, Susanne

    2012-01-01

    textabstractBeta-blockers are frequently prescribed to implantable cardioverter-defibrillator (ICD) patients. Beta-blocker therapy has been proposed to induce emotional distress such as depression and anxiety, but a paucity of studies has examined the relationship between beta-blockers and distress. We investigated the association between beta-blocker therapy, including type and dosage, and symptoms of anxiety and depression in a consecutive cohort of patients receiving an ICD. Between 2003 a...

  20. Late Development of a Bronchocutaneous Fistula due to an Epicardial Cardioverter-Defibrillator Lead

    Directory of Open Access Journals (Sweden)

    Vasileios Patris

    2015-10-01

    Full Text Available Cutaneous complications caused by a pacemaker or defibrillator are widely documented, but the development of a bronchocutaneous fistula has never been described before. We report the case of a 79-year-old man who was admitted to our hospital because of a seemingly superficial cutaneous infection, externalized defibrillator leads, and hemoptysis. Bronchoscopical investigation proved the existence of the fistula, which connected the epicardium, the left main bronchus, and the aforementioned site of skin infection. The patient refused an operation for the complete removal of the epicardial defibrillator and was treated conservatively. This case demonstrated that the long-term presence of foreign bodies in the epicardium may cause serious complications

  1. Efficacy of cognitive behavioral therapy in reducing psychiatric symptoms in patients with implantable cardioverter defibrillator: an integrative review.

    Science.gov (United States)

    Maia, A C C O; Braga, A A; Soares-Filho, G; Pereira, V; Nardi, A E; Silva, A C

    2014-04-01

    This article is a systematic review of the available literature on the benefits that cognitive behavioral therapy (CBT) offers patients with implanted cardioverter defibrillators (ICDs) and confirms its effectiveness. After receiving the device, some patients fear that it will malfunction, or they remain in a constant state of tension due to sudden electrical discharges and develop symptoms of anxiety and depression. A search with the key words "anxiety", "depression", "implantable cardioverter", "cognitive behavioral therapy" and "psychotherapy" was carried out. The search was conducted in early January 2013. Sources for the search were ISI Web of Knowledge, PubMed, and PsycINFO. A total of 224 articles were retrieved: 155 from PubMed, 69 from ISI Web of Knowledge. Of these, 16 were written in a foreign language and 47 were duplicates, leaving 161 references for analysis of the abstracts. A total of 19 articles were eliminated after analysis of the abstracts, 13 were eliminated after full-text reading, and 11 articles were selected for the review. The collection of articles for literature review covered studies conducted over a period of 13 years (1998-2011), and, according to methodological design, there were 1 cross-sectional study, 1 prospective observational study, 2 clinical trials, 4 case-control studies, and 3 case studies. The criterion used for selection of the 11 articles was the effectiveness of the intervention of CBT to decrease anxiety and depression in patients with ICD, expressed as a ratio. The research indicated that CBT has been effective in the treatment of ICD patients with depressive and anxiety symptoms. Research also showed that young women represented a risk group, for which further study is needed. Because the number of references on this theme was small, further studies should be carried out.

  2. Implantable Cardioverter-defibrillator Therapy for Hypertrophic Cardiomyopathy: Usefulness in Primary and Secondary Prevention.

    Science.gov (United States)

    Sarrias, Axel; Galve, Enrique; Sabaté, Xavier; Moya, Àngel; Anguera, Ignacio; Núñez, Elaine; Villuendas, Roger; Alcalde, Óscar; García-Dorado, David

    2015-06-01

    Hypertrophic cardiomyopathy is a frequent cause of sudden death. Clinical practice guidelines indicate defibrillator implantation for primary prevention in patients with 1 or more risk factors and for secondary prevention in patients with a history of aborted sudden death or sustained ventricular arrhythmias. The aim of the present study was to analyze the follow-up of patients who received an implantable defibrillator following the current guidelines in nonreferral centers for this disease. This retrospective observational study included all patients who underwent defibrillator implantation between January 1996 and December 2012 in 3 centers in the province of Barcelona. The study included 69 patients (mean age [standard deviation], 44.8 [17] years; 79.3% men), 48 in primary prevention and 21 in secondary prevention. The mean number of risk factors per patient was 1.8 in the primary prevention group and 0.5 in the secondary prevention group (P=.029). The median follow-up duration was 40.5 months. The appropriate therapy rate was 32.7/100 patient-years in secondary prevention and 1.7/100 patient-years in primary prevention (P<.001). Overall mortality was 10.1%. Implant-related complications were experienced by 8.7% of patients, and 13% had inappropriate defibrillator discharges. In patients with a defibrillator for primary prevention, the appropriate therapy rate is extremely low, indicating the low predictive power of the current risk stratification criteria. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  3. First inappropriate implantable cardioverter defibrillator therapy is often due to inaccurate device programming: analysis of the French OPERA registry.

    Science.gov (United States)

    Leenhardt, Antoine; Defaye, Pascal; Mouton, Elisabeth; Delay, Marc; Delarche, Nicolas; Dupuis, Jean-Marc; Bizeau, Olivier; Mabo, Philippe; Cheggour, Saida; Babuty, Dominique

    2012-10-01

    Inappropriate therapy delivered by implantable cardioverter defibrillators (ICDs) remains a challenge. The OPERA registry measured the times to, and studied the determinants of, first appropriate (FAT) and inappropriate (FIT) therapies delivered by single-, dual- and triple-chamber [cardiac resynchronization therapy defibrillator (CRT-D)] ICD. We entered 636 patients (mean age = 62.0 ± 13.5 years; 88% men) in the registry, of whom 251 received single-, 238 dual-, and 147 triple-chamber ICD, for primary (30.5%) or secondary (69.5%) indications. We measured times to FAT and FIT as a function of multiple clinical characteristics, examined the effects of various algorithm components on the likelihood of FAT and FIT delivery, and searched for predictors of FAT and FIT. Over 22.8 ± 8.8 months of observation, 184 patients (28.9%) received FAT and 70 (11.0%) received FIT. Ventricular tachycardia (VT) was the trigger of 88% of FAT, and supraventricular tachycardia was the trigger of 91% of FIT. The median times to FIT (90 days; range 49-258) and FAT (171 days; 50-363) were similar. The rate of FAT was higher (P <0.001) in patients treated for secondary than primary indications, while that of FIT were similar in both groups. Out of 57 analysable FIT, 27 (47.4%) could have been prevented by fine tuning the device programming like the sustained rate duration or the VT discrimination algorithm. First inappropriate therapy occurred in 11% of 636 ICD recipients followed for ∼2 years. Nearly 50% of FIT could have been prevented by improving device programming.

  4. Comparative Evaluation of Four Risk Scores for Predicting Mortality in Patients With Implantable Cardioverter-defibrillator for Primary Prevention.

    Science.gov (United States)

    Rodríguez-Mañero, Moisés; Abu Assi, Emad; Sánchez-Gómez, Juan Miguel; Fernández-Armenta, Juan; Díaz-Infante, Ernesto; García-Bolao, Ignacio; Benezet-Mazuecos, Juan; Andrés Lahuerta, Ana; Expósito-García, Víctor; Bertomeu-González, Vicente; Arce-León, Álvaro; Barrio-López, María Teresa; Peinado, Rafael; Martínez-Sande, Luis; Arias, Miguel A

    2016-11-01

    Several clinical risk scores have been developed to identify patients at high risk of all-cause mortality despite implantation of an implantable cardioverter-defibrillator. We aimed to examine and compare the predictive capacity of 4 simple scoring systems (MADIT-II, FADES, PACE and SHOCKED) for predicting mortality after defibrillator implantation for primary prevention of sudden cardiac death in a Mediterranean country. A multicenter retrospective study was performed in 15 Spanish hospitals. Consecutive patients referred for defibrillator implantation between January 2010 and December 2011 were included. A total of 916 patients with ischemic and nonischemic heart disease were included (mean age, 62 ± 11 years, 81.4% male). Over 33.4 ± 12.9 months, 113 (12.3%) patients died (cardiovascular origin in 86 [9.4%] patients). At 12, 24, 36, and 48 months, mortality rates were 4.5%, 7.6%, 10.8%, and 12.3% respectively. All the risk scores showed a stepwise increase in the risk of death throughout the scoring system of each of the scores and all 4 scores identified patients at greater risk of mortality. The scores were significantly associated with all-cause mortality throughout the follow-up period. PACE displayed the lowest c-index value regardless of whether the population had heart disease of ischemic (c-statistic = 0.61) or nonischemic origin (c-statistic = 0.61), whereas MADIT-II (c-statistic = 0.67 and 0.65 in ischemic and nonischemic cardiomyopathy, respectively), SHOCKED (c-statistic = 0.68 and 0.66, respectively), and FADES (c-statistic = 0.66 and 0.60) provided similar c-statistic values (P ≥ .09). In this nontrial-based cohort of Mediterranean patients, the 4 evaluated risk scores showed a significant stepwise increase in the risk of death. Among the currently available risk scores, MADIT-II, FADES, and SHOCKED provide slightly better performance than PACE. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All

  5. Association of air pollution with increased incidence of ventricular tachyarrhythmias recorded by implantable cardioverter defibrillators: Vulnerable patients to air pollution.

    Science.gov (United States)

    Kim, In-Soo; Sohn, Jungwoo; Lee, Seung-Jun; Park, Jin-Kyu; Uhm, Jae-Sun; Pak, Hui-Nam; Lee, Moon-Hyoung; Kim, Changsoo; Joung, Boyoung

    2017-08-01

    This study investigated the acute effects of exposure to air pollution on ventricular tachyarrhythmias (VTAs) in an East Asian population. The association between air pollution and VTA has not yet been studied in an East Asian country affected by the Asian dust phenomenon, which worsens air quality. The study cohort consisted of 160patients with implantable cardioverter defibrillator (ICD) devices in the Seoul metropolitan area who were followed for 5.5±3.8years. We used ICD records of VTAs and matched these with hourly measurements of air pollutant concentrations and meteorological data. Fine particle mass and gaseous air pollution plus temperature and relative humidity were measured hourly during the study period. During the study period, 1064 VTA events including 204 instances of ventricular fibrillation (VF) were observed. We found a statistically significant association between overall VTA events and SO2 (lag 24h; OR 1.49, 95%CI 1.16-1.92, p=0.002), PM10 (lag 2h; OR 2.56, 95%CI 2.03-3.23, pair pollution and VTA were observed in a metropolitan area of an East Asian country. Exposures to SO2, PM10, NO2, and CO were significantly associated with VTAs in ICD patients with SHD. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Safety Profile of Liver FibroScan in Patients with Cardiac Pacemakers or Implantable Cardioverter-Defibrillators

    Science.gov (United States)

    Pranke, Stephanie; Rashidi, Farid; Nosib, Shravan; Worobetz, Lawrence

    2017-01-01

    Background. Emerging evidence suggests that nonalcoholic fatty liver disease (NAFLD) is associated with coronary artery diseases and arrhythmias. The FibroScan (Echosens, France), a widely available, noninvasive device, is able to detect liver fibrosis and steatosis within this patient population. However, the FibroScan is currently contraindicated in patients with cardiac pacemakers (PM) or implantable cardioverter-defibrillators (ICD). Objective. To determine the safety profile of FibroScan testing in patients with PM or ICD. Methods. Consecutive outpatients undergoing routine device interrogations at a tertiary level teaching hospital underwent simultaneous liver stiffness measurements. PM or ICD performance data, device types, patient demographics, medical history, and previous laboratory and conventional liver imaging results were collected. Results. Analysis of 107 subjects with 33 different types of implanted cardiac devices, from 5 different companies (Medtronic, Sorin, ELA Medical, Boston Scientific, and St. Jude), did not demonstrate any adverse events as defined by abnormal device sensing/pacing or ICD firing. This population included high risk subjects undergoing active pacing (n = 53) and with right pectoral PM placement (n = 1). None of the subjects had any clinical signs of decompensated congestive heart failure or cirrhosis during the exam. Conclusion. TE with FibroScan can be safely performed in patients with PM or ICD.

  7. A pilot study of a mindfulness based stress reduction program in adolescents with implantable cardioverter defibrillators or pacemakers.

    Science.gov (United States)

    Freedenberg, Vicki A; Thomas, Sue A; Friedmann, Erika

    2015-04-01

    Adolescents with implantable cardioverter defibrillators (ICDs) or pacemakers (PMs) face unique challenges that can cause psychosocial distress. Psychosocial interventions are effective for adults with cardiac devices and could potentially impact adolescents' adjustment to these devices. Mindfulness Based Stress Reduction (MBSR) is a structured psycho-educational program that includes meditation, yoga, and group support and has been studied extensively among adults. This study examined the feasibility of the MBSR program for adolescents with ICDs/PMs, a population previously unexamined in the research literature. The participants completed measures of anxiety and depression (Hospital Anxiety and Depression Scale) and coping (Responses to Stress Questionnaire) at baseline and after the six-session MBSR intervention. Mean age of the cohort (n = 10) was 15 ± 3 years, 6 were male, 6 had a PM, and 4 had an ICD. Feasibility was demonstrated by successful recruitment of 10 participants, 100 % participation and completion. Anxiety decreased significantly following the intervention, with a large effect size, t[9] = 3.67, p MBSR interventions in adolescents with high-risk cardiac diagnoses.

  8. Risk of pacemaker or implantable cardioverter defibrillator after radiotherapy for early-stage breast cancer in Denmark, 1982-2005.

    Science.gov (United States)

    Rehammar, Jens Christian; Johansen, Jens Brock; Jensen, Maj-Britt; Videbæk, Lars; Jørgensen, Ole Dan; Lorenzen, Ebbe; Ewertz, Marianne

    2017-01-01

    To examine the risk of cardiac conduction abnormalities or severe ventricular arrhythmias requiring implantation of a cardiac implantable electronic device (CIED), either a pacemaker or an implantable cardioverter-defibrillator, subsequent to breast cancer (BC) radiotherapy (RT). All women treated for early-stage BC in Denmark from 1982 to 2005 were identified from the Danish Breast Cancer Cooperative Group. By record linkage to the Danish Pacemaker and ICD Registry information was retrieved on CIED implants subsequent to RT. Standardized incidence ratios (SIR) of CIED implantation were estimated for women receiving RT and compared to women not receiving RT for BC. Uni- and multivariate Poisson regression models were used to estimate incidence rate ratios (IRR) among irradiated women compared to non-irradiated. Of 44,423 BC patients, 179 had a CIED implanted among 18,251 women who received RT, and 401 had a CIED in 26,172 who did not receive RT. The unadjusted IRR was 1.09 (0.91-1.30 95% CI) for CIED implants among women receiving RT compared to non-irradiated women and the IRR was 1.13 (0.93-1.38 95% CI) when adjustments were made. BC RT as practiced in Denmark in 1982-2005 did not increase the risk of CIED implants. This indicates that RT for BC does not increase the risk of severe ventricular arrhythmias or cardiac conduction abnormalities. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  9. Impact of new X-ray technology on patient dose in pacemaker and implantable cardioverter defibrillator (ICD) implantations.

    Science.gov (United States)

    van Dijk, Joris D; Ottervanger, Jan Paul; Delnoy, Peter Paul H M; Lagerweij, Martine C M; Knollema, Siert; Slump, Cornelis H; Jager, Pieter L

    2017-01-01

    New X-ray technology providing new image processing techniques may reduce radiation exposure. The aim of this study was to quantify this radiation exposure reduction for patients during pacemaker and implantable cardioverter defibrillator (ICD) implantation. In this retrospective study, 1185 consecutive patients who had undergone de novo pacemaker or ICD implantation during a 2-year period were included. All implantations in the first year were performed using the reference technology (Allura Xper), whereas in the second year, the new X-ray technology (AlluraClarity) was used. Radiation exposure, expressed as the dose area product (DAP), was compared between the two time periods to determine the radiation exposure reduction for pacemaker and ICD implantations without cardiac resynchronization therapy (CRT) and with CRT. Procedure duration and contrast volume were used as measures to compare complexity and image quality. The study population consisted of 591 patients who had undergone an implantation using the reference technology, and 594 patients with the new X-ray technology. The two groups did not differ in age, gender, or body mass index. The DAP decreased with 69 % from 16.4 ± 18.5 to 5.2 ± 6.6 Gy cm(2) for the non-CRT implantations (p pacemaker and ICD implantation while image quality was unaffected.

  10. Relationship between right and left ventricular function in candidates for implantable cardioverter defibrillator with low left ventricular ejection fraction.

    Science.gov (United States)

    Jimenez-Juan, Laura; Karur, Gauri R; Connelly, Kim A; Deva, Djeven; Yan, Raymond T; Wald, Rachel M; Singh, Sheldon; Leung, General; Oikonomou, Anastasia; Dorian, Paul; Angaran, Paul; Yan, Andrew T

    2017-04-01

    Indications for the primary prevention of sudden death using an implantable cardioverter defibrillator (ICD) are based predominantly on left ventricular ejection fraction (LVEF). However, right ventricular ejection fraction (RVEF) is also a known prognostic factor in a variety of structural heart diseases that predispose to sudden cardiac death. We sought to investigate the relationship between right and left ventricular parameters (function and volume) measured by cardiovascular magnetic resonance (CMR) among a broad spectrum of patients considered for an ICD. In this retrospective, single tertiary-care center study, consecutive patients considered for ICD implantation who were referred for LVEF assessment by CMR were included. Right and left ventricular function and volumes were measured. In total, 102 patients (age 62±14 years; 23% women) had a mean LVEF of 28±11% and RVEF of 44±12%. The left ventricular and right ventricular end diastolic volume index was 140±42 mL/m(2) and 81±27 mL/m(2), respectively. Eighty-six (84%) patients had a LVEF right ventricular systolic dysfunction. Although there was a significant and moderate correlation between LVEF and RVEF (r=0.40, pright ventricular systolic dysfunction (Kappa=0.041). Among patients being considered for an ICD, there is a positive but moderate correlation between LVEF and RVEF. A considerable proportion of patients who qualify for an ICD based on low LVEF have preserved RVEF, and vice versa.

  11. Prophylactic use of implantable cardioverter-defibrillators in the elderly population

    Institute of Scientific and Technical Information of China (English)

    Yuchuan LIU; Hue-Teh Shih

    2005-01-01

    @@ Introduction Sudden cardiac death (SCD) accounts for approximately 300,000 deaths each year in the United States. Ventricular fibrillation, as the initial event, had been reported in 65%-85% of these patients.1 An implantable cardioverterdefibrillator (ICD) is the single most effective life saving device to date. The advances in medicine and technology have led to wide spread utilization of defibrillators in developed countries.

  12. Desfibrilador cardioversor automático implantável: experiência inicial Implantable cardioverter defibrillator: initial experience

    Directory of Open Access Journals (Sweden)

    Victor BAUER JÚNIOR

    1999-04-01

    Full Text Available Este estudo tem por objetivo demonstrar o protocolo de implante, técnica utilizada, avaliação dos parâmetros iniciais do implante de desfibrilador cardioversor automático implantável (DCAI e seguimento precoce dos 15 pacientes operados em nosso Serviço. O implante transvenoso nessa série de pacientes obteve sucesso em 14 casos. O limiar de desfibrilação teve média de 8,05 ± 4,60 Joules, onda R 16,00 ± 4,32 mV, "slew rate" 1,25 ± 0,29 V/s, limiar de comando de 0,65 ± 0,80 Volts e resistência de 620,00 ± 102,77 Ohms. O tempo médio de implante foi de 164,17 ± 71,15 minutos. Não ocorreu morte operatória, nem episódios de rejeição ou infecção. A média de seguimento foi de 18,79 ± 13,81 meses sendo que 9 pacientes receberam choques apropriados com reversão das arritmias. Choques inapropriados ocorreram em uma paciente devido à perda do limiar de sensibilidade do cardioversor. Observamos a facilidade técnica do implante utilizando o modelo Phylax 06 na região infraclavicular esquerda com eletrodo único, sendo o DCAI capaz de reconhecer e realizar a terapia de cardioversão ou desfibrilação com sucesso, sugerindo ser um método importante e eficaz para o tratamento dos pacientes que desenvolvem arritmias com alto risco de mortalidade em ambulatório.The implantable cardioverter-defibrillator (ICD is gaining increasing significance in therapy of life-threatening ventricular arrhythmias. Mirowski started to develop experimental automatic implantable defibrillators in the seventies. In 1980, the first human implant of an automatic implantable defibrillator was done by the team of Mirowski in Baltimore, USA. The purpose of this report is to examine 15 implantation at our Institution. Adequate defibrillation thresholds with were obrtained mean 8.0 Joules, slew rate 1.25 V/s and impedance of 620 Ohms. All implants were performed with non-thoracotomy lead, two abdominal implantations and three left pectoral implantations

  13. Inhibition of bradycardia pacing caused by far-field atrial sensing in a third-generation cardioverter defibrillator with an automatic gain feature.

    Science.gov (United States)

    Curwin, J H; Roelke, M; Ruskin, J N

    1996-01-01

    The diagnostic accuracy of implantable cardioverter defibrillators may be improved by automatically adjusting gain algorithms, which in general reduce the likelihood of oversensing while maintaining the ability to detect the low amplitude signals associated with ventricular fibrillation. We present a patient with a third-generation device who developed prolonged ventricular asystole arising as a complication of the automatic gain feature. During asystole the device automatically increased sensitivity in order to prevent undersensing of ventricular fibrillation, which in this case resulted in far-field sensing of atrial activity and inhibition of ventricular pacing.

  14. Pacemakers and implantable cardioverter defibrillators, unknown to chest radiography: Review, complications and systematic reading

    Energy Technology Data Exchange (ETDEWEB)

    Alandete Germán, Salvador Pascual, E-mail: salaiger@gmail.com; Isarria Vidal, Santiago, E-mail: isarria@comv.es; Domingo Montañana, María Luisa, E-mail: domingo.luimon@gmail.com; De la vía Oraá, Esperanza, E-mail: esviao82@gmail.com; Vilar Samper, José, E-mail: vilarsamper@gmail.com

    2015-03-15

    Highlights: •Radiologists have an important function in the evaluation of these devices. •We revise their radiological appearances and possible complications. •The knowledge in normal aspects and complications is important for radiologist. •To ensure an accurate reading of the chest x-ray, we present a systematic approach. -- Abstract: Chest X-ray is the imaging technique of choice for an initial study of pacemakers and implantable cardio-defibrillators (ICD). Radiologists have an important role in the evaluation of its initial placement and in the assessment during its follow-up. For this reason, it is necessary to know not only the different existing devices and its components but also the reasons of malfunction or possible complications. The purpose of this article is to do a systematic review of the different types of pacemakers and ICD. We review their usual radiological appearances, the possible complications which might take place and its causes of malfunctioning.

  15. Psychological wellbeing and posttraumatic stress associated with implantable cardioverter defibrillator therapy in young adults with genetic heart disease.

    Science.gov (United States)

    Ingles, Jodie; Sarina, Tanya; Kasparian, Nadine; Semsarian, Christopher

    2013-10-09

    Sudden cardiac death is a tragic complication of a number of genetic heart diseases. Implantable cardioverter defibrillator (ICD) therapy plays an important role in prevention of sudden death. The psychological consequences of ICD therapy in young people with genetic heart disease are poorly understood. This study sought to better understand psychological wellbeing and identify symptoms of posttraumatic stress in young people who had experienced an ICD shock. Eligible patients (ICD implanted over 12 months prior) with an inherited cardiomyopathy or primary arrhythmogenic disorder, enrolled in the Australian Genetic Heart Disease Registry were included. Ninety patients completed the Hospital Anxiety and Depression Scale (HADS). Those patients who had an ICD shock (n=31) also completed the Impact of Events Scale-Revised (IES-R). While the mean HADS-Anxiety and IES-R scores were within the normal range in the total group (n=90), a significant subgroup reported symptoms of anxiety (38%), depression (17%) and posttraumatic stress (31%) indicative of the potential need for referral to clinical care. Overall, greater psychological distress in ICD patients was associated with female gender, a history of syncope, other comorbid medical conditions, and reporting of other distressing events (i.e., ICD complications). In those with an ICD shock, higher posttraumatic stress scores were associated with female gender and longer time to first shock. Patients with genetic heart diseases can experience psychological difficulties, including anxiety, depression and posttraumatic stress, related to ICD implantation and subsequent shocks. This signals the importance of offering patients access to targeted interventions, including psychological care and support. © 2013.

  16. Efficacy of cognitive behavioral therapy in reducing psychiatric symptoms in patients with implantable cardioverter defibrillator: an integrative review

    Directory of Open Access Journals (Sweden)

    A.C.C.O. Maia

    2014-04-01

    Full Text Available This article is a systematic review of the available literature on the benefits that cognitive behavioral therapy (CBT offers patients with implanted cardioverter defibrillators (ICDs and confirms its effectiveness. After receiving the device, some patients fear that it will malfunction, or they remain in a constant state of tension due to sudden electrical discharges and develop symptoms of anxiety and depression. A search with the key words “anxiety”, “depression”, “implantable cardioverter”, “cognitive behavioral therapy” and “psychotherapy” was carried out. The search was conducted in early January 2013. Sources for the search were ISI Web of Knowledge, PubMed, and PsycINFO. A total of 224 articles were retrieved: 155 from PubMed, 69 from ISI Web of Knowledge. Of these, 16 were written in a foreign language and 47 were duplicates, leaving 161 references for analysis of the abstracts. A total of 19 articles were eliminated after analysis of the abstracts, 13 were eliminated after full-text reading, and 11 articles were selected for the review. The collection of articles for literature review covered studies conducted over a period of 13 years (1998-2011, and, according to methodological design, there were 1 cross-sectional study, 1 prospective observational study, 2 clinical trials, 4 case-control studies, and 3 case studies. The criterion used for selection of the 11 articles was the effectiveness of the intervention of CBT to decrease anxiety and depression in patients with ICD, expressed as a ratio. The research indicated that CBT has been effective in the treatment of ICD patients with depressive and anxiety symptoms. Research also showed that young women represented a risk group, for which further study is needed. Because the number of references on this theme was small, further studies should be carried out.

  17. Potential clinical impact of cardiovascular magnetic resonance assessment of ejection fraction on eligibility for cardioverter defibrillator implantation

    Directory of Open Access Journals (Sweden)

    Joshi Subodh B

    2012-10-01

    Full Text Available Abstract Background For the primary prevention of sudden cardiac death, guidelines provide left ventricular ejection fraction (EF criteria for implantable cardioverter defibrillator (ICD placement without specifying the technique by which it should be measured. We sought to investigate the potential impact of performing cardiovascular magnetic resonance (CMR for EF on ICD eligibility. Methods The study population consisted of patients being considered for ICD implantation who were referred for EF assessment by CMR. Patients who underwent CMR within 30 days of echocardiography were included. Echocardiographic EF was determined by Simpson’s biplane method and CMR EF was measured by Simpson’s summation of discs method. Results Fifty-two patients (age 62±15 years, 81% male had a mean EF of 38 ± 14% by echocardiography and 35 ± 14% by CMR. CMR had greater reproducibility than echocardiography for both intra-observer (ICC, 0.98 vs 0.94 and inter-observer comparisons (ICC 0.99 vs 0.93. The limits of agreement comparing CMR and echocardiographic EF were – 16 to +10 percentage points. CMR resulted in 11 of 52 (21% and 5 of 52 (10% of patients being reclassified regarding ICD eligibility at the EF thresholds of 35 and 30% respectively. Among patients with an echocardiographic EF of between 25 and 40%, 9 of 22 (41% were reclassified by CMR at either the 35 or 30% threshold. Echocardiography identified only 1 of the 6 patients with left ventricular thrombus noted incidentally on CMR. Conclusions CMR resulted in 21% of patients being reclassified regarding ICD eligibility when strict EF criteria were used. In addition, CMR detected unexpected left ventricular thrombus in almost 10% of patients. Our findings suggest that the use of CMR for EF assessment may have a substantial impact on management in patients being considered for ICD implantation.

  18. Cognitive-Behavioral Treatment of Posttraumatic Stress in Patients With Implantable Cardioverter Defibrillators: Results From a Randomized Controlled Trial.

    Science.gov (United States)

    Ford, Jessica; Rosman, Lindsey; Wuensch, Karl; Irvine, Jane; Sears, Samuel F

    2016-08-01

    Approximately 20% of patients with implantable cardioverter defibrillators (ICDs) suffer from posttraumatic stress disorder (PTSD) due to a history of cardiac arrest, device implantation, and ICD shock. There has been very little examination of treatment of PTSD symptoms in these patients. This study evaluated the effect of a specific cognitive-behavioral therapy (CBT) intervention for ICD patients with high levels of PTSD symptoms: a manualized program consisting of 8 telephone sessions with a trained counselor, a patient education book, and a stress management procedure on compact disc. Participants were 193 ICD patients, who were randomized to CBT or usual cardiac care (UCC) who completed self-report surveys at the time of recruitment and 6 and 12 months after initial measurement. Previous publication on the primary research evaluation questions reported that the CBT condition resulted in greater improvement on PTSD and depression symptoms than the UCC for the general population of ICD patients, but did not evaluate the effect on those with elevated symptoms of PTSD. The authors conducted secondary analyses of the effect of treatment on high and low PTSD symptom groups based on a cutoff for the Impact of Event Scale-Revised (Weiss & Marmar, 1997). Participants in the CBT group who had high symptoms experienced significantly greater symptom reduction from baseline to 12 months (d = 2.44, p = .021) than the UCC group (d = 1.12). Participants with low symptoms had small reductions regardless of group assignment (d = 0.16, p = .031). ICD-focused CBT was sufficient to produce a large, statistically significant reduction in PTSD symptoms in ICD patients with indications for treatment.

  19. Wrong detection of ventricular fibrillation in an implantable cardioverter defibrillator caused by the movement near the MRI scanner bore.

    Science.gov (United States)

    Mattei, Eugenio; Censi, Federica; Triventi, Michele; Mancini, Matteo; Napolitano, Antonio; Genovese, Elisabetta; Cannata, Vittorio; Falsaperla, Rosaria; Calcagnini, Giovanni

    2015-01-01

    The static magnetic field generated by MRI systems is highly non-homogenous and rapidly decreases when moving away from the bore of the scanner. Consequently, the movement around the MRI scanner is equivalent to an exposure to a time-varying magnetic field at very low frequency (few Hz). For patients with an implanted cardiac stimulators, such as an implantable cardioverter/defibrillator (ICD), the movements inside the MRI environment may thus induce voltages on the loop formed by the leads of the device, with the potential to affect the behavior of the stimulator. In particular, the ICD's detection algorithms may be affected by the induced voltage and may cause inappropriate sensing, arrhythmia detections, and eventually inappropriate ICD therapy.We performed in-vitro measurements on a saline-filled humanshaped phantom (male, 170 cm height), equipped with an MRconditional ICD able to transmit in real-time the detected cardiac activity (electrograms). A biventricular implant was reproduced and the ICD was programmed in standard operating conditions, but with the shock delivery disabled. The electrograms recorded in the atrial, left and right ventricle channels were monitored during rotational movements along the vertical axis, in close proximity of the bore. The phantom was also equipped with an accelerometer and a magnetic field probe to measure the angular velocity and the magnetic field variation during the experiment. Pacing inhibition, inappropriate detection of tachyarrhythmias and of ventricular fibrillation were observed. Pacing inhibition began at an angular velocity of about 7 rad/s, (dB/dt of about 2 T/s). Inappropriate detection of ventricular fibrillation occurred at about 8 rad/s (dB/dt of about 3 T/s). These findings highlight the need for a specific risk assessment of workers with MR-conditional ICDs, which takes into account also effects that are generally not considered relevant for patients, such as the movement around the scanner bore.

  20. Costs of remote monitoring vs. ambulatory follow-ups of implanted cardioverter defibrillators in the randomized ECOST study

    Science.gov (United States)

    Guédon-Moreau, Laurence; Lacroix, Dominique; Sadoul, Nicolas; Clémenty, Jacques; Kouakam, Claude; Hermida, Jean-Sylvain; Aliot, Etienne; Kacet, Salem

    2014-01-01

    Aims The Effectiveness and Cost of ICD follow-up Schedule with Telecardiology (ECOST) trial evaluated prospectively the economic impact of long-term remote monitoring (RM) of implantable cardioverter defibrillators (ICDs). Methods and results The analysis included 310 patients randomly assigned to RM (active group) vs. ambulatory follow-ups (control group). Patients in the active group were seen once a year unless the system reported an event mandating an ambulatory visit, while patients in the control group were seen in the ambulatory department every 6 months. The costs of each follow-up strategy were compared, using the actual billing documents issued by the French health insurance system, including costs of (i) (a) ICD-related ambulatory visits and transportation, (b) other ambulatory visits, (c) cardiovascular treatments and procedures, and (ii) hospitalizations for the management of cardiovascular events. The ICD and RM system costs were calculated on the basis of the device remaining longevity at the end of the study. The characteristics of the study groups were similar. Over a follow-up of 27 months, the mean non-hospital costs per patient-year were €1695 ± 1131 in the active, vs. €1952 ± 1023 in the control group (P = 0.04), a €257 difference mainly due to device management. The hospitalization costs per patient-year were €2829 ± 6382 and €3549 ± 9714 in the active and control groups, respectively (P = 0.46). Adding the ICD to the non-hospital costs, the savings were €494 (P = 0.005) or, when the monitoring system was included, €315 (P = 0.05) per patient-year. Conclusion From the French health insurance perspective, the remote management of ICD patients is cost saving. Clinical trials registration NCT00989417, www.clinicaltrials.gov PMID:24614572

  1. Implantable cardioverter defibrillator therapy in pediatric and congenital heart disease patients: a single tertiary center experience in Korea

    Directory of Open Access Journals (Sweden)

    Bo Kyung Jin

    2013-03-01

    Full Text Available Purpose: The use of implantable cardioverter defibrillators (ICDs to prevent sudden cardiac death is increasing in children and adolescents. This study investigated the use of ICDs in children with congenital heart disease. Methods: This retrospective study was conducted on the clinical characteristics and effectiveness of ICD implantation at the department of pediatrics of a single tertiary center between 2007 and 2011. Results: Fifteen patients underwent ICD implantation. Their mean age at the time of implantation was 14.5±5.4 years (range, 2 to 22 years. The follow-up duration was 28.9±20.4 months. The cause of ICD implantation was cardiac arrest in 7, sustained ventricular tachycardia in 6, and syncope in 2 patients. The underlying disorders were as follows: ionic channelopathy in 6 patients (long QT type 3 in 4, catecholaminergic polymorphic ventricular tachycardia [CPVT] in 1, and J wave syndrome in 1, cardiomyopathy in 5 patients, and postoperative congenital heart disease in 4 patients. ICD coils were implanted in the pericardial space in 2 children (ages 2 and 6 years. Five patients received appropriate ICD shock therapy, and 2 patients received inappropriate shocks due to supraventricular tachycardia.During follow-up, 2 patients required lead dysfunction-related revision. One patient with CPVT suffered from an ICD storm that was resolved using sympathetic denervation surgery. Conclusion: The overall ICD outcome was acceptable in most pediatric patients. Early diagnosis and timely ICD implantation are recommended for preventing sudden death in high-risk children and patients with congenital heart disease.

  2. [Rehabilitation of patients with cardiac pacemakers and implanted cardioverter-defibrillators: recommendations for training, physiotherapeutic procedures and re-employment].

    Science.gov (United States)

    Reibis, R K; Kamke, W; Langheim, E; Völler, H

    2010-04-01

    Rehabilitation of patients with cardiac pacemakers (CP) or implantable cardioverter defibrillators (ICD) comprises secondary prevention of underlying cardiac disease, conditioning training activities and psychological education and includes furthermore the assessment of aggregate function, detection of any device malfunction as well as the return to work efforts. The extent to which the physical activities can be permitted is determined by both cardiopulmonary capacity and the primary arrhythmic indication. Under consideration of upper frequency limit, left ventricular dysfunction and the avoidance of mechanical exposure on device can and leads, an individually designed training programme is acceptable even on a high load level. Likewise, electrotherapeutic procedures due to musculoskeletal pain syndrome are not generally contraindicated, if differentiated limitations are respected. Beside the assessment of aggregate function and, if necessary, parameter optimization, psychologic intervention programs play an important role particularly in ICD-patients and can be utilized as an additive therapeutic module. Personalized recommendations for driving with an ICD are determined by the time interval since idex arrhythmia and the rhythmological risk profile as well as by the motor vehicle class. The return to work rate of CP and ICD patients is resumably influenced by the underlying cardiac disease and to a lesser extend by the implanted device. Except industrial jobs the risk of electromagnetic interference during the working process is low and can be objected by working place analysis including noise field measurement. Thus cardiac of CP and ICD patients should be used to a large extend for the recovery of individual physical and psychological integrity as well as for the organisation of reemployment.

  3. Management of radiation oncology patients with implanted cardiac pacemakers or implant able cardioverter defibrilators; Tratamiento de pacientes en radioterapia con marcapasos o desfibriladores automaticos implantables

    Energy Technology Data Exchange (ETDEWEB)

    Martin Martin, G.

    2012-07-01

    The increase in life expectancy along with the technological development in the last decades has resulted in an increase in the number of patients requiring pacemaker implants or implantable cardioverter defibrillators worldwide. An increase in the number of patients with implanted cardiac devices in radiotherapy is also expected due to the risk factors in common between heart disease and cancer. In 1994 the American Association of Physicists in Medicine (AAPM) released a report about the management of radiation oncology patients with implanted cardiac pacemakers. The addition of new technologies, both in radiotherapy units and in the manufacturing process of heart devices, has shown the need for an updated protocol for the management of these patients. In this work, the most important articles published after the report of the AAPM have been compiled, in order to analyze the effects not previously studied such as dose rate, scattered radiation, electromagnetic interference or random failures produced by neutrons and protons. Additionally, the latest recommendations given by the manufacturers have been analyzed and, finally, some indications are given as an updated guide for the management of radiation oncology patients with pacemakers or cardioverter defibrillators implanted. (Author)

  4. Nurse- and peer-led self-management programme for patients with an implantable cardioverter defibrillator; a feasibility study

    Directory of Open Access Journals (Sweden)

    van Eijk Jacques

    2007-09-01

    Full Text Available Abstract Background The prevalence of cardiovascular disease is increasing. Improved treatment options increase survival after an acute myocardial infarction or sudden cardiac arrest, although patients often have difficulty adjusting and regaining control in daily life. In particular, patients who received an implantable cardioverter defibrillator (ICD experience physical and psychological problems. Interventions to enhance perceived control and acceptance of the device are therefore necessary. This paper describes a small-scale study to explore the feasibility and the possible benefits of a structured nurse- and peer-led self-management programme ('Chronic Disease Self-Management Program' – CDSMP among ICD patients. Methods Ten male ICD patients (mean age = 65.5 years participated in a group programme, consisting of six sessions, led by a team consisting of a nurse specialist and a patient with cardiovascular disease. Programme feasibility was evaluated among patients and leaders by measuring performance of the intervention according to protocol, attendance and adherence of the participating ICD patients, and patients' and leaders' opinions about the programme. In addition, before and directly after attending the intervention, programme benefits (e.g. perceived control, symptoms of anxiety and depression, and quality of life were assessed. Results The programme was conducted largely according to protocol. Eight patients attended at least four sessions, and adherence ranged from good to very good. On average, the patients reported to have benefited very much from the programme, which they gave an overall report mark of 8.4. The leaders considered the programme feasible as well. Furthermore, improvements were identified for general self-efficacy expectancies, symptoms of anxiety, physical functioning, social functioning, role limitations due to physical problems, and pain. Conclusion This study suggests that a self-management programme led by a

  5. Methodological limitations of psychosocial interventions in patients with an implantable cardioverter-defibrillator (ICD A systematic review

    Directory of Open Access Journals (Sweden)

    Ockene Ira S

    2009-12-01

    Full Text Available Abstract Background Despite the potentially life-saving benefits of the implantable cardioverter-defibrillator (ICD, a significant group of patients experiences emotional distress after ICD implantation. Different psychosocial interventions have been employed to improve this condition, but previous reviews have suggested that methodological issues may limit the validity of such interventions. Aim: To review the methodology of previously published studies of psychosocial interventions in ICD patients, according to CONSORT statement guidelines for non-pharmacological interventions, and provide recommendations for future research. Methods We electronically searched the PubMed, PsycInfo and Cochrane databases. To be included, studies needed to be published in a peer-reviewed journal between 1980 and 2008, to involve a human population aged 18+ years and to have an experimental design. Results Twelve studies met the eligibility criteria. Samples were generally small. Interventions were very heterogeneous; most studies used cognitive behavioural therapy (CBT and exercise programs either as unique interventions or as part of a multi-component program. Overall, studies showed a favourable effect on anxiety (6/9 and depression (4/8. CBT appeared to be the most effective intervention. There was no effect on the number of shocks and arrhythmic events, probably because studies were not powered to detect such an effect. Physical functioning improved in the three studies evaluating this outcome. Lack of information about the indication for ICD implantation (primary vs. secondary prevention, limited or no information regarding use of anti-arrhythmic (9/12 and psychotropic (10/12 treatment, lack of assessments of providers' treatment fidelity (12/12 and patients' adherence to the intervention (11/12 were the most common methodological limitations. Conclusions Overall, this review supports preliminary evidence of a positive effect of psychosocial interventions

  6. Temporal Influence of Heart Failure Hospitalizations Prior to Implantable Cardioverter Defibrillator or Cardiac Resynchronization Therapy With Defibrillator on Subsequent Outcome in Mild Heart Failure Patients (from MADIT-CRT)

    DEFF Research Database (Denmark)

    Lee, Andy Y; Moss, Arthur J; Ruwald, Martin H;

    2015-01-01

    The temporal effect of heart failure (HF) hospitalization occurring at different time periods before implantation has not yet been studied in detail. The aim of the present study was to investigate the potential association between time from last HF hospitalization to device implantation and effe......The temporal effect of heart failure (HF) hospitalization occurring at different time periods before implantation has not yet been studied in detail. The aim of the present study was to investigate the potential association between time from last HF hospitalization to device implantation...... and effects on subsequent outcomes and benefit from cardiac resynchronization therapy with a defibrillator (CRT-D). Multivariate Cox models were used to determine the temporal influence of previous HF hospitalization on the end point of HF or death within all left bundle branch block implantable cardioverter......-defibrillator (ICD) and CRT-D patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT) trial (n = 1,250) and to evaluate the clinical benefit of CRT-D implantation, comparing CRT-D patients with ICD patients within each previous HF hospitalization...

  7. Gender differences in appropriate shocks and mortality among patients with primary prophylactic implantable cardioverter-defibrillators: Systematic review and meta-analysis

    CERN Document Server

    Conen, David; Röver, Christian; Bergau, Leonard; Muñoz, Pascal; Wijers, Sofieke; Sticherling, Christian; Zabel, Markus; Friede, Tim

    2016-01-01

    BACKGROUND: Some but not all prior studies have shown that women receiving a primary prophylactic implantable cardioverter defibrillator (ICD) have a lower risk of death and appropriate shocks than men. PURPOSE: To evaluate the effect of gender on the risk of appropriate shock, all-cause mortality and inappropriate shock in contemporary studies of patients receiving a primary prophylactic ICD. DATA SOURCE: PubMed, LIVIVO, Cochrane CENTRAL between 2010 and 2016. STUDY SELECTION: Studies providing at least 1 gender-specific risk estimate for the outcomes of interest. DATA EXTRACTION: Abstracts were screened independently for potentially eligible studies for inclusion. Thereby each abstract was reviewed by at least two authors. DATA SYNTHESIS: Out of 680 abstracts retained by our search strategy, 20 studies including 46'657 patients had gender-specific information on at least one of the relevant endpoints. Mean age across the individual studies varied between 58 and 69 years. The proportion of women enrolled ran...

  8. A Young Man Presenting with Pleuritic Chest Pain and Fever after Electrophysiological Study and Implantable Cardioverter-Defibrillator Placement: Diagnostic Difficulties and Value of Bedside Thoracic Sonography.

    Science.gov (United States)

    Faraone, Antonio; Fortini, Alberto

    2015-01-01

    We describe the case of a 23-year-old man presenting with recurrent pleuritic chest pain and prolonged fever after electrophysiology testing and placement of an implantable cardioverter-defibrillator because of a suspected arrhythmogenic right ventricular dysplasia. The clinical suspicion was initially directed toward pneumonia with pleural effusion and later toward an infection of the cardiac device complicated by septic pulmonary embolism. The definitive diagnosis of pulmonary embolism and infarction was suggested by a point-of-care thoracic sonography, performed at the bedside by a clinician caring for the patient, and then confirmed by contrast enhanced computed tomography, which also showed thrombosis of the left iliofemoral vein, site of percutaneous puncture for cardiac catheterization. Prolonged fever was attributable to a concomitant Epstein-Barr virus primary infection that acted as confounding factor. The present report confirms the value of bedside thoracic sonography in the diagnostic evaluation of patients with nonspecific respiratory symptoms.

  9. A Young Man Presenting with Pleuritic Chest Pain and Fever after Electrophysiological Study and Implantable Cardioverter-Defibrillator Placement: Diagnostic Difficulties and Value of Bedside Thoracic Sonography

    Directory of Open Access Journals (Sweden)

    Antonio Faraone

    2015-01-01

    Full Text Available We describe the case of a 23-year-old man presenting with recurrent pleuritic chest pain and prolonged fever after electrophysiology testing and placement of an implantable cardioverter-defibrillator because of a suspected arrhythmogenic right ventricular dysplasia. The clinical suspicion was initially directed toward pneumonia with pleural effusion and later toward an infection of the cardiac device complicated by septic pulmonary embolism. The definitive diagnosis of pulmonary embolism and infarction was suggested by a point-of-care thoracic sonography, performed at the bedside by a clinician caring for the patient, and then confirmed by contrast enhanced computed tomography, which also showed thrombosis of the left iliofemoral vein, site of percutaneous puncture for cardiac catheterization. Prolonged fever was attributable to a concomitant Epstein-Barr virus primary infection that acted as confounding factor. The present report confirms the value of bedside thoracic sonography in the diagnostic evaluation of patients with nonspecific respiratory symptoms.

  10. Implantable cardioverter-defibrillator therapy in a 34-year-old patient with eating disorders and after the third sudden cardiac arrest.

    Science.gov (United States)

    Piotrowicz, Ewa; Orzechowski, Piotr; Bilinska, Maria; Przybylski, Andrzej; Szumowski, Lukasz; Piotrowicz, Ryszard

    2015-03-01

    Eating disorders (ED) such as anorexia nervosa and bulimia are psychiatric diseases associated with the highest mortality rate of any other psychiatric disorders. More recently, long-term outcome studies with follow-up of over 20 years report a mortality of between 15% and 18% (Casiero and Frishman, Cardiol Rev 14(5), 227, 2006). The sudden death secondary to arrhythmias is often the cause of death in these patients (Casiero and Frishman, Cardiol Rev 14(5), 227, 2006). A case of life-threatening ventricular arrhythmia (VA) in a patient with ED is presented. Clinical records (cardiologic, psychiatric), electrocardiograms, echocardiogram, coronary angiogram, cardiac magnetic resonance, and endocrine diagnostics were performed. Finally a cardioverter-defibrillator (ICD) was implanted in the patient after her third cardiac arrest. An optimal approach to antiarrhythmic therapy in such patients is a real challenge for a cardiologist.

  11. Results of ENHANCED Implantable Cardioverter Defibrillator Programming to Reduce Therapies and Improve Quality of Life (from the ENHANCED-ICD Study).

    Science.gov (United States)

    Mastenbroek, Mirjam H; Pedersen, Susanne S; van der Tweel, Ingeborg; Doevendans, Pieter A; Meine, Mathias

    2016-02-15

    Novel implantable cardioverter defibrillator (ICD) discrimination algorithms and programming strategies have significantly reduced the incidence of inappropriate shocks, but there are still gains to be made with respect to reducing appropriate but unnecessary antitachycardia pacing (ATP) and shocks. We examined whether programming a number of intervals to detect (NID) of 60/80 for ventricular tachyarrhythmia (VT)/ventricular fibrillation (VF) detection was safe and the impact of this strategy on (1) adverse events related to ICD shocks and syncopal events; (2) ATPs/shocks; and (3) patient-reported outcomes. The "ENHANCED Implantable Cardioverter Defibrillator programming to reduce therapies and improve quality of life" study (ENHANCED-ICD study) was a prospective, safety-monitoring study enrolling 60 primary and secondary prevention patients at the University Medical Center Utrecht. Patients implanted with any type of ICD with SmartShock technology and aged 18 to 80 years were eligible to participate. In all patients, a prolonged NID 60/80 was programmed. The cycle length for VT/fast VT/VF was 360/330/240 ms, respectively. Programming a NID 60/80 proved safe for ICD patients. Because of the new programming strategy, unnecessary ICD therapy was prevented in 10% of ENHANCED-ICD patients during a median follow-up period of 1.3 years. With respect to patient-reported outcomes, levels of distress were highest and perceived health status lowest at the time of implantation, which both gradually improved during follow-up. In conclusion, the ENHANCED-ICD study demonstrates that programming a NID 60/80 for VT/VF detection is safe for ICD patients and does not negatively impact their quality of life.

  12. Disease-specific quality of life-patient acceptance: racial and gender differences in patients with implantable cardioverter defibrillators.

    Science.gov (United States)

    Wilson, Mary H; Engelke, Martha K; Sears, Samuel F; Swanson, Melvin; Neil, Janice A

    2013-01-01

    Despite its established effectiveness, living with an implantable cardioverter defibrillator (ICD) is associated with ongoing physical and psychosocial distress. Little is known about which factors impact the patients' adjustment to living with the device and whether there are racial or gender differences related to these factors. The purpose of this study was to investigate factors (demographic, clinical, psychosocial, and religiosity) related to patients' ICD acceptance and to examine racial and gender differences in ICD acceptance. A total of 101 ICD patients (mean age, 65 ± 12.8 years, 34% female, 42% African American [AA]) seen in a cardiology clinic between January and August 2010 completed the Florida Patient Acceptance Survey (FPAS), Florida shock anxiety scale, ENRICHD social support instrument, hospital anxiety and depression scale, Hoge Religiosity Scale, and a demographic sheet during their clinic visit. All multiple-item scales demonstrated good internal consistency reliability, with Cronbach α values ranging from .77 to .89. Overall patient acceptance of the ICD was high, with an average FPAS acceptance score of 80.9 on the 0-to-100 point scale. The FPAS subscale scores indicated that the group was very positive about the benefits of having the device (mean, 90.3) and had few body image concerns (mean, 10.6), low device-related distress (mean, 15.6), and moderate return to function scores (mean, 63.0). White ICD participants were more accepting of their device than AA ICD patients were, scoring statistically significantly higher than AA patients on total patient acceptance and return to function and significantly lower than AA patients on device-related distress and shock anxiety. Controlling for ethnicity (β = .10, P = .15), age (β = .01, P = .90), and number of comorbidities (β = .19, P = .003) in a hierarchical multiple regression, shock anxiety (β = .31, P < .001), knowledge of the device (β = .23, P = .001), social support (β = .13, P

  13. Implantable cardioverter-defibrillator

    Science.gov (United States)

    ... the heart to beat in a more coordinated fashion. Why the Procedure is Performed An ICD is ... Controlling your high blood pressure Dietary fats explained Fast food tips Heart attack - discharge Heart disease - risk ...

  14. Implantable cardioverter defibrillator - discharge

    Science.gov (United States)

    ... hair dryer, stove, CD player, remote controls, and microwave. There are several devices you should keep at ... Tell your provider about every shock you feel from your ICD. The settings of your ICD may need to be adjusted, or your medicines may need to ...

  15. Cardiac Resynchronization Therapy Reduces Ventricular Arrhythmias in Primary but Not Secondary Prophylactic Implantable Cardioverter Defibrillator Patients: Insight From the Resynchronization in Ambulatory Heart Failure Trial.

    Science.gov (United States)

    Sapp, John L; Parkash, Ratika; Wells, George A; Yetisir, Elizabeth; Gardner, Martin J; Healey, Jeffrey S; Thibault, Bernard; Sterns, Laurence D; Birnie, David; Nery, Pablo B; Sivakumaran, Soori; Essebag, Vidal; Dorian, Paul; Tang, Anthony S L

    2017-03-01

    The RAFT (Resynchronization in Ambulatory Heart Failure Trial) demonstrated that cardiac resynchronization therapy (CRT) reduced both mortality and heart failure hospitalizations in patients with functional class II or III heart failure and widened QRS. We examined the influence of CRT on ventricular arrhythmias in patients with primary versus secondary prophylaxis defibrillator indications. All ventricular arrhythmias among RAFT study participants were downloaded and adjudicated by 2 blinded reviewers with an overreader for disagreements and committee review for remaining discrepancies. Incidence of ventricular arrhythmias among patients randomized to CRT-D versus implantable cardioverter defibrillator (ICD) were compared within the groups of patients treated for primary prophylaxis and for secondary prophylaxis. Of 1798 enrolled patients, 1764 had data available for adjudication and were included. Of these, 1531 patients were implanted for primary prophylaxis, while 233 patients were implanted for secondary prophylaxis; 884 patients were randomized to ICD and 880 to CRT-D. During 5953.6 patient-years of follow-up, there were 11 278 appropriate ICD detections of ventricular arrhythmias. In the primary prophylaxis group, CRT-D significantly reduced incidence ventricular arrhythmias in comparison to ICD (hazard ratio, 0.86; 95% confidence interval, 0.74-0.99; P=0.044). This effect was not seen in the secondary prophylaxis group (hazard ratio, 1.14; 95% confidence interval, 0.82-1.58; P=0.45). CRT-D was not associated with significant differences in overall ventricular arrhythmia burden in either group. CRT reduced the rate of onset of new ventricular arrhythmias detected by ICDs in patients without a history of prior ventricular arrhythmias. This effect was not observed among patients who had prior ventricular arrhythmias. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00251251. © 2017 American Heart Association, Inc.

  16. Educational and psychological interventions to improve outcomes for recipients of implantable cardioverter defibrillators and their families: a scientific statement from the American Heart Association.

    Science.gov (United States)

    Dunbar, Sandra B; Dougherty, Cynthia M; Sears, Samuel F; Carroll, Diane L; Goldstein, Nathan E; Mark, Daniel B; McDaniel, George; Pressler, Susan J; Schron, Eleanor; Wang, Paul; Zeigler, Vicki L

    2012-10-23

    Significant mortality benefits have been documented in recipients of implantable cardioverter defibrillators (ICDs); however, the psychosocial distress created by the underlying arrhythmia and its potential treatments in patients and family members may be underappreciated by clinical care teams. The disentanglement of cardiac disease and device-related concerns is difficult. The majority of ICD patients and families successfully adjust to the ICD, but optimal care pathways may require additional psychosocial attention to all ICD patients and particularly those experiencing psychosocial distress. This state-of-the-science report was developed on the basis of an analysis and critique of existing science to (1) describe the psychological and quality-of-life outcomes after receipt of an ICD and describe related factors, such as patient characteristics; (2) describe the concerns and educational/informational needs of ICD patients and their family members; (3) outline the evidence that supports interventions for improving educational and psychological outcomes for ICD patients; (4) provide recommendations for clinical approaches for improving patient outcomes; and (5) identify priorities for future research in this area. The ultimate goal of this statement is to improve the precision of identification and care of psychosocial distress in ICD patients to maximize the derived benefit of the ICD.

  17. Appropriate evaluation and treatment of heart failure patients after implantable cardioverter-defibrillator discharge: time to go beyond the initial shock.

    Science.gov (United States)

    Mishkin, Joseph D; Saxonhouse, Sherry J; Woo, Gregory W; Burkart, Thomas A; Miles, William M; Conti, Jamie B; Schofield, Richard S; Sears, Samuel F; Aranda, Juan M

    2009-11-24

    Multiple clinical trials support the use of implantable cardioverter-defibrillators (ICDs) for prevention of sudden cardiac death in patients with heart failure (HF). Unfortunately, several complicating issues have arisen from the universal use of ICDs in HF patients. An estimated 20% to 35% of HF patients who receive an ICD for primary prevention will experience an appropriate shock within 1 to 3 years of implant, and one-third of patients will experience an inappropriate shock. An ICD shock is associated with a 2- to 5-fold increase in mortality, with the most common cause being progressive HF. The median time from initial ICD shock to death ranges from 168 to 294 days depending on HF etiology and the appropriateness of the ICD therapy. Despite this prognosis, current guidelines do not provide a clear stepwise approach to managing these high-risk patients. An ICD shock increases HF event risk and should trigger a thorough evaluation to determine the etiology of the shock and guide subsequent therapeutic interventions. Several combinations of pharmacologic and device-based interventions such as adding amiodarone to baseline beta-blocker therapy, adjusting ICD sensitivity, and employing antitachycardia pacing may reduce future appropriate and inappropriate shocks. Aggressive HF surveillance and management is required after an ICD shock, as the risk of sudden cardiac death is transformed to an increased HF event risk.

  18. Effect of psycho-educational interventions on quality of life in patients with implantable cardioverter defibrillators: a meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Kao, Chi-Wen; Chen, Miao-Yi; Chen, Ting-Yu; Lin, Pai-Hui

    2016-09-30

    Implantable cardioverter defibrillators (ICD) were developed for primary and secondary prevention of sudden cardiac death. However, ICD recipients' mortality is significantly predicted by their quality of life (QOL). The aim of this meta-analysis was to evaluate the effects of psycho-educational interventions on QOL in patients with ICDs. We systematically searched PubMed, Medline, Cochrane Library, and CINAHL through April 2015 and references of relevant articles. Studies were reviewed if they met following criteria: (1) randomized controlled trial, (2) participants were adults with an ICD, and (3) data were sufficient to evaluate the effect of psychological or educational interventions on QOL measured by the SF-36 or SF-12. Studies were independently selected and their data were extracted by two reviewers. Study quality was evaluated using a modified Jadad scale. The meta-analysis was conducted using the Cochrane Collaboration's Review Manager Software Package (RevMan 5). Study heterogeneity was assessed by Q statistics and I (2) statistic. Depending on heterogeneity, data were pooled across trials using fixed-effect or random-effect modeling. Seven randomized controlled trials fulfilled the inclusion and exclusion criteria, and included 1017 participants. The psycho-educational interventions improved physical component summary (PCS) scores in the intervention groups more than in control groups (mean difference 2.08, 95 % CI 0.86 to 3.29, p educational interventions improved the physical component, but not the mental component of QOL in patients with ICDs.

  19. A priori expectancy bias and its relation to shock experience and anxiety: a naturalistic study in patients with an automatic implantable cardioverter defibrillator.

    Science.gov (United States)

    Pauli, P; Wiedemann, G; Dengler, W; Kühlkamp, V

    2001-09-01

    Patients with an automatic implantable cardioverter defibrillator (AICD) may offer an unique naturalistic opportunity to study whether expectancy biases develop because of precipitating aversive or traumatic experiences and/or because of elevated anxiety. An expectancy bias and its associations with AICD discharge and anxiety was examined in 24 AICD patients with a thought experiment. While patients without AICD discharge exhibited no expectancy bias, patients with discharge experiences were found to expect that stimuli depicting medical emergency situations will be followed by an aversive consequence. The magnitude of their expectancy bias was positively correlated with their anxiety level. In the group with AICD discharge, patients with low anxiety levels exhibited no bias, while patients with high anxiety levels exhibited a rather strong bias. It seems that the experience of an aversive or traumatic event, here an AICD discharge, is a necessary (but not sufficient) precipitating event for the development of an expectancy bias. If such an event happens, trait anxiety level presumably determines if and how strong the expectancy bias will be.

  20. Importance of ventricular tachycardia storms not terminated by implantable cardioverter defibrillators shocks in patients with CASQ2 associated catecholaminergic polymorphic ventricular tachycardia.

    Science.gov (United States)

    Marai, Ibrahim; Khoury, Asaad; Suleiman, Mahmoud; Gepstein, Lior; Blich, Miri; Lorber, Abraham; Boulos, Monther

    2012-07-01

    In this study, the clinical and implantable cardioverter-defibrillator (ICD)-related follow-up of patients with catecholaminergic polymorphic ventricular tachycardia (CPVT) with homogenous missense mutations in CASQ2 was summarized. Patients were followed in a pediatric cardiology clinic and an ICD clinic. All patients were treated with high-dose β blockers. ICDs were recommended for patients who remained symptomatic despite medical treatment. Twenty-seven patients were followed for 1 to 15 years (median 9). Twenty patients (74%) were symptomatic at diagnosis; 13 (65%) remained symptomatic after treatment with high-dose β blockers and thus were advised to receive ICDs. Eight of these patients refused ICDs, and eventually 6 (75%) died suddenly. Four of the 5 patients who received ICDs had ventricular tachycardia storms treated but not terminated by recurrent ICD shocks. These ventricular tachycardia storms (2 episodes in 2 patients and 1 episode in 2 patient) terminated spontaneously after finishing the programmed ICD shocks, without degeneration to ventricular fibrillation. None of the patients who received ICDs died. In conclusion, patients with CASQ2-associated CPVT should be recommended to receive ICDs to prevent sudden death when medical therapy is not effective. These patients may have recurrent ventricular tachycardia storms treated but not terminated by recurrent ICD shocks, without degeneration to ventricular fibrillation. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Role of implantable cardioverter defibrillator in non-ischemic cardiomyopathy: a systematic review and meta-analysis of prospective randomized clinical trials.

    Science.gov (United States)

    Romero, Jorge; Chaudhary, Rahul; Garg, Jalaj; Lupercio, Florentino; Shah, Neeraj; Gupta, Rahul; Nazir, Talha; Bozorgnia, Babak; Natale, Andrea; Di Biase, Luigi

    2017-09-01

    A mortality benefit in patients with implantable cardioverter defibrillator (ICD) in ischemic cardiomyopathy is well established. However, the benefit of ICD implantation in non-ischemic cardiomyopathy (NICM) on total mortality remains uncertain. We performed a systematic review and meta-analysis of randomized controlled trials (RCT) evaluating the role of primary prevention ICD in NICM patients. We performed a systematic review on PubMed, The Cochrane Library, EMBASE, EBSCO, Web of Science, and CINAHL databases from the inception through February 2017 to identify RCT evaluating the role of ICD in NICM patients. Mantel-Haenszel risk ratio (RR) fixed effects model was used to summarize data across treatment arms. If heterogeneity (I (2)) ≥25, random effects model was used instead. We analyzed a total of 2573 patients from five RCTs comparing ICD with medical therapy in patients with NICM. The mean follow up for the trials was 48 ± 22 months. There was a significant reduction in (a) all-cause mortality (RR 0.84, 95% CI 0.71-0.99, p = 0.03) and (b) sudden cardiac death (RR 0.47, 95% CI 0.30-0.73, p < 0.001) in ICD group versus medical therapy. Our analysis demonstrates that the use of ICD for primary prevention is associated with a reduction in all-cause mortality and SCD in patients with NICM.

  2. Lack of current implantable cardioverter defibrillator guidelines application for primary prevention of sudden cardiac death in Latin American patients with heart failure: a cross-sectional study.

    Science.gov (United States)

    Gonzalez-Zuelgaray, Jorge; Pellizon, Oscar; Muratore, Claudio A; Oropeza, Elsa Silva; Rabinovich, Rafael; Ramos, José Luis; Tentori, Maria Cristina; Reyes, Nicolás; Aguayo, Rubén; Marin, Jorge; Peterson, Brett J

    2013-02-01

    This cross-sectional study evaluated the application of accepted international implantable cardioverter defibrillator (ICD) guidelines for primary prevention of sudden cardiac death in patients with heart failure. The PLASMA (Probabilidad de Sufrir Muerte Arritmica) study was designed to characterize management of cardiac patients in Latin America. Twelve centres included 1958 consecutively admitted patients in cardiology units in 2008 and 2009. Discharged patients were evaluated for primary prevention, ICD indication and prescription by general cardiologists. Of 1711 discharged patients, 1525 (89%) had data available for evaluating indication status. Class I indications for ICD therapy were met for 153 (10%) patients based on collected data. Only 20 (13%, 95% confidence interval: 7.7-18.4%) patients with indication were prescribed an ICD. Patients prescribed an ICD were younger than patients who were not prescribed an ICD (62 vs. 68 years, P < 0.01). The reasons given by cardiologists for not prescribing an ICD for 133 patients with an indication were: indication criteria not met (75%), life expectancy <1 year (9.7%), rejection by the patient (5.2%), no medical coverage paying for the device (3.7%), psychiatric patient (2.2%), and other reasons (4.2%). In Latin America, international guidelines for primary prevention ICD implantation are not well followed. The main reason is that cardiologists believe that patients do not meet indication criteria, even though study data confirm that criteria are met. This poses a significant challenge and underlines the importance of continuous and improved medical education.

  3. Long-term benefit of first-line peri-implantable cardioverter-defibrillator implant ventricular tachycardia-substrate ablation in secondary prevention patients.

    Science.gov (United States)

    Acosta, Juan; Cabanelas, Nuno; Penela, Diego; Fernández-Armenta, Juan; Andreu, David; Borràs, Roger; Korshunov, Viatcheslav; Cabrera, Mario; Vasanelli, Francesca; Arbelo, Elena; Guasch, Eduard; Martínez, Mikel; Tolosana, Jose M; Mont, Lluis; Berruezo, Antonio

    2017-06-01

    This study assessed the benefit of peri-implantable cardioverter-defibrillator implant ventricular tachycardia (VT)-substrate ablation in patients with structural heart disease (SHD). Patients with SHD and indication for secondary prevention ICD implant were prospectively included. Patients presenting with incessant and/or slow VT or frequent (≥2) VT episodes who underwent peri-ICD VT-substrate ablation (the scar dechannelling technique) were compared with those who received ICD alone and did not meet ablation criteria. The primary endpoint was any sustained VT/ICD therapy during follow-up. Of 206 patients included (43.2% non-ischaemic), 70 were assigned to ablation and 136 received ICD implant alone. During a mean follow-up of 45.6 ± 24.7 months, the primary endpoint was more frequent in the non-ablation group (47.1 vs. 22.9%; Pimplant VT-substrate ablation was associated with decreased VT recurrence and ICD shocks during long-term follow-up in patients with SHD and indication for secondary prevention ICD implant, especially in ischaemic patients. In patients with LVEF <35%, no benefit was observed in terms of VT recurrence-free survival, although VT burden during follow-up was lower in the ablation group.

  4. Heart rate variability density analysis (Dyx) for identification of appropriate implantable cardioverter defibrillator recipients among elderly patients with acute myocardial infarction and left ventricular systolic dysfunction

    DEFF Research Database (Denmark)

    Jørgensen, Rikke Mørch; Levitan, Jacob; Halevi, Zohar

    2015-01-01

    AIMS: Dyx is a new heart rate variability (HRV) density analysis specifically designed to identify patients at high risk for malignant ventricular arrhythmias. The aim of this study was to test if Dyx can improve risk stratification for malignant ventricular tachyarrhythmias and to test if the pr......AIMS: Dyx is a new heart rate variability (HRV) density analysis specifically designed to identify patients at high risk for malignant ventricular arrhythmias. The aim of this study was to test if Dyx can improve risk stratification for malignant ventricular tachyarrhythmias and to test...... if the previously identified cut-off can be reproduced. METHODS AND RESULTS: This study included 248 patients from the CARISMA study with ejection fraction ≤40% after an acute myocardial infarction and an analysable 24 h Holter recording. All patients received an implantable cardiac monitor, which was used...... to diagnose the primary endpoint of near-fatal or fatal ventricular tachyarrhythmias likely preventable by an implantable cardioverter defibrillator (ICD), during a period of 2 years. A Dyx ≤ 1.96 was considered abnormal. The secondary endpoint was cardiovascular death. At enrolment 59 patients (24%) had...

  5. The mismatch between patient life expectancy and the service life of implantable devices in current cardioverter-defibrillator therapy: a call for larger device batteries.

    Science.gov (United States)

    Neuzner, Jörg

    2015-06-01

    In 2005, Bob Hauser published a paper in the Journal of the American College of Cardiology entitled "The growing mismatch between patient longevity and the service life of Implantable Cardioverter-Defibrillators". Now, nearly a decade later, I would like to perform a second look on the problem of a mismatching between ICD device service life and the survival of ICD recipients. Since 2005, the demographics of the ICD population has changed significantly. Primary prevention has become the dominant indication in defibrillator therapy and device implantation is indicated more and more in earlier stages of cardiac diseases. In former larger scale ICD trials, the patient average 5-year survival probability was in a range of 68-71%; in newer CRT-D trials in a range of 72-88%. Due to a progressively widened ICD indication and implantation preferentially performed in patients with better life expectancy, the problem of inadequate device service life is of growing importance. The early days of defibrillator therapy started with a generator volume of 145 ccm and a device service life life were similar challenges for the technicians. Today, we have reached a formerly unexpected extent of device miniaturization. However, technologic improvements were often preferentially translated in further device miniaturization and not in prolonging device service life. In his analysis, Bob Hauser reported a prolonged device service life of 2.3 years in ICD models with a larger battery capacity of 0.54 up to 0.69 Ah. Between 2008 and 2014, several studies had been published on the problem of ICD longevity in clinical scenarios. These analyses included "older" and currently used single chamber, dual chamber and CRT devices. The reported average 5-year device service life ranged from 0 to 75%. Assuming today technology, larger battery capacities will only result in minimal increase in device volume. Selected ICD patients may further benefit from device miniaturization-but the vast majority

  6. Longevity of implantable cardioverter-defibrillators for cardiac resynchronization therapy in current clinical practice: an analysis according to influencing factors, device generation, and manufacturer.

    Science.gov (United States)

    Landolina, Maurizio; Curnis, Antonio; Morani, Giovanni; Vado, Antonello; Ammendola, Ernesto; D'onofrio, Antonio; Stabile, Giuseppe; Crosato, Martino; Petracci, Barbara; Ceriotti, Carlo; Bontempi, Luca; Morosato, Martina; Ballari, Gian Paolo; Gasparini, Maurizio

    2015-08-01

    Device replacement at the time of battery depletion of implantable cardioverter-defibrillators (ICDs) may carry a considerable risk of complications and engenders costs for healthcare systems. Therefore, ICD device longevity is extremely important both from a clinical and economic standpoint. Cardiac resynchronization therapy defibrillators (CRT-D) battery longevity is shorter than ICDs. We determined the rate of replacements for battery depletion and we identified possible determinants of early depletion in a series of patients who had undergone implantation of CRT-D devices. We retrieved data on 1726 consecutive CRT-D systems implanted from January 2008 to March 2010 in nine centres. Five years after a successful CRT-D implantation procedure, 46% of devices were replaced due to battery depletion. The time to device replacement for battery depletion differed considerably among currently available CRT-D systems from different manufacturers, with rates of batteries still in service at 5 years ranging from 52 to 88% (log-rank test, P < 0.001). Left ventricular lead output and unipolar pacing configuration were independent determinants of early depletion [hazard ratio (HR): 1.96; 95% 95% confidence interval (CI): 1.57-2.46; P < 0.001 and HR: 1.58, 95% CI: 1.25-2.01; P < 0.001, respectively]. The implantation of a recent-generation device (HR: 0.57; 95% CI: 0.45-0.72; P < 0.001), the battery chemistry and the CRT-D manufacturer (HR: 0.64; 95% CI: 0.47-0.89; P = 0.008) were additional factors associated with replacement for battery depletion. The device longevity at 5 years was 54%. High left ventricular lead output and unipolar pacing configuration were associated with early battery depletion, while recent-generation CRT-Ds displayed better longevity. Significant differences emerged among currently available CRT-D systems from different manufacturers. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Cardiology.

  7. Combined etiology of anaphylactic cardiogenic shock: Amiodarone, epinephrine, cardioverter defibrillator, left ventricular assist devices and the Kounis syndrome

    Directory of Open Access Journals (Sweden)

    Nicholas G Kounis

    2015-01-01

    Full Text Available Anaphylactic shock is a life-threatening condition which needs detailed and mediculous clinical assessment and thoughtful treatment. Several causes can join forces in order to degranulate mast cells. Amiodarone which is an iodine-containing highly lipophilic benzofuran can induce allergic reactions and anaphylactic shock in sensitized patients. Epinephrine is a life saving drug, but in sulfite allergic patients it should be given with caution due its metabisulfite preservative. Metals covering cardiac defibrillators and pacemakers can act as antigens attached to serum proteins and induce allergic reactions. In anaphylactic shock, myocardial involvement due to vasospasm-induced coronary blood flow reduction manifesting as Kounis syndrome should be always considered. Clinically, combined treatment targeting the primary cause of anaphylaxis together with protection of cardiac tissue seems to be of paramount importance.

  8. Impact of the implantable cardioverter defibrillator on confidence to undertake physical activity in inherited heart disease: A cross-sectional study.

    Science.gov (United States)

    Sweeting, Joanna; Ball, Kylie; McGaughran, Julie; Atherton, John; Semsarian, Christopher; Ingles, Jodie

    2017-06-01

    Physical activity is associated with improved quality of life. Patients with an implantable cardioverter defibrillator (ICD) face unique clinical and psychological challenges. Factors such as fear of ICD shock may negatively impact on physical activity, while a sense of protection gained from the ICD may instil confidence to be active. We aimed to examine the impact of an ICD on physical activity levels and factors associated with amount of activity. Two cross-sectional studies were conducted. Accelerometer data (seven-day) was collected in March-November 2015 for 63 consecutively recruited hypertrophic cardiomyopathy patients, with or without an ICD, aged ⩾18 years. A survey study was conducted in July-August 2016 of 155 individuals aged ⩾18 years with an inherited heart disease and an ICD in situ. Based on the International Physical Activity Questionnaire, mean leisure time physical activity was 239 ± 300 min/week with 51% meeting physical activity guidelines. Accelerometry showed that mean moderate-vigorous physical activity was the same for patients with and without an ICD (254 ± 139 min/week versus 300 ± 150 min/week, p=0.23). Nearly half of survey participants ( n=73) said their device made them more confident to exercise. Being anxious about ICD shocks was the only factor associated with not meeting physical activity guidelines. Patients with inherited heart disease adjust differently to their ICD device, and for many it has no impact on physical activity. Discussion regarding the appropriate level of physical activity and potential barriers will ensure best possible outcomes in this unique patient group.

  9. Cardiovascular Magnetic Resonance to Predict Appropriate Implantable Cardioverter Defibrillator Therapy in Ischemic and Nonischemic Cardiomyopathy Patients Using Late Gadolinium Enhancement Border Zone: Comparison of Four Analysis Methods.

    Science.gov (United States)

    Jablonowski, Robert; Chaudhry, Uzma; van der Pals, Jesper; Engblom, Henrik; Arheden, Håkan; Heiberg, Einar; Wu, Katherine C; Borgquist, Rasmus; Carlsson, Marcus

    2017-09-01

    Late gadolinium enhancement (LGE) border zone on cardiac magnetic resonance imaging has been proposed as an independent predictor of ventricular arrhythmias. The purpose was to determine whether size and heterogeneity of LGE predict appropriate implantable cardioverter defibrillator (ICD) therapy in ischemic cardiomyopathy (ICM) and nonischemic cardiomyopathy (NICM) patients and to evaluate 4 LGE border-zone algorithms. ICM and NICM patients who underwent LGE cardiac magnetic resonance imaging prior to ICD implantation were retrospectively included. Two semiautomatic algorithms, expectation maximization, weighted intensity, a priori information and a weighted border zone algorithm, were compared with a modified full-width half-maximum and a 2-3SD threshold-based algorithm (2-3SD). Hazard ratios were calculated per 1% increase in LGE. A total of 74 ICM and 34 NICM were followed for 63 months (1-140) and 52 months (0-133), respectively. ICM patients had 27 appropriate ICD events, and NICM patients had 7 ICD events. In ICM patients with primary prophylactic ICD, LGE border zone predicted ICD therapy in univariable and multivariable analysis measured by the expectation maximization, weighted intensity, a priori information, weighted border zone, and modified full-width half-maximum algorithms (hazard ratios 1.23, 1.22, and 1.05, respectively; P<0.05; negative predictive value 92%). For NICM, total LGE by all 4 methods was the strongest predictor (hazard ratios, 1.03-1.04; P<0.05), though the number of events was small. Appropriate ICD therapy can be predicted in ICM patients with primary prevention ICD by quantifying the LGE border zone. In NICM patients, total LGE but not LGE border zone had predictive value for ICD therapy. However, the algorithms used affects the predictive value of these measures. © 2017 American Heart Association, Inc.

  10. Cardiac sympathetic innervation assessed with (123)I-MIBG retains prognostic utility in diabetic patients with severe left ventricular dysfunction evaluated for primary prevention implantable cardioverter-defibrillator.

    Science.gov (United States)

    García-González, P; Fabregat-Andrés, Ó; Cozar-Santiago, P; Sánchez-Jurado, R; Estornell-Erill, J; Valle-Muñoz, A; Quesada-Dorador, A; Payá-Serrano, R; Ferrer-Rebolleda, J; Ridocci-Soriano, F

    2016-01-01

    Scintigraphy with iodine-123-metaiodobenzylguanidine ((123)I-MIBG) is a non-invasive tool for the assessment of cardiac sympathetic innervation (CSI) that has proven to be an independent predictor of survival. Recent studies have shown that diabetic patients with heart failure (HF) have a higher deterioration in CSI. It is unknown if (123)I-MIBG has the same predictive value for diabetic and non-diabetic patients with advanced HF. An analysis is performed to determine whether CSI with (123)I-MIBG retains prognostic utility in diabetic patients with HF, evaluated for a primary prevention implantable cardioverter-defibrillator (ICD). Seventy-eight consecutive HF patients (48 diabetic) evaluated for primary prevention ICD implantation were prospectively enrolled and underwent (123)I-MIBG to assess CSI (heart-to-mediastinum ratio - HMR). A Cox proportional hazards multivariate analysis was used to determine the influence of (123)I-MIBG images for prediction of cardiac events in both diabetic and non-diabetic patients. The primary end-point was a composite of arrhythmic event, cardiac death, or admission due to HF. During a mean follow-up of 19.5 [9.3-29.3] months, the primary end-point occurred in 24 (31%) patients. Late HMR was significantly lower in diabetic patients (1.30 vs. 1.41, p=0.014). Late HMR≤1.30 was an independent predictor of cardiac events in diabetic (hazard ratio 4.53; p=0.012) and non-diabetic patients (hazard ratio 12.31; p=0.023). Diabetic patients with HF evaluated for primary prevention ICD show a higher deterioration in CSI than non-diabetics; nevertheless (123)I-MIBG imaging retained prognostic utility for both diabetic and non-diabetic patients. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  11. Response to programmed ventricular stimulation and clinical outcome in cardiac arrest survivors receiving randomised assignment to implantable cardioverter defibrillator or antiarrhythmic drug therapy.

    Science.gov (United States)

    Cappato, Riccardo; Boczor, Sigrid; Kuck, Karl-Heinz

    2004-04-01

    Using a prospective design which randomly assigned implantable cardioverter defibrillator (ICD) versus antiarrhythmic drugs (AADs), we investigated the usefulness of programmed ventricular stimulation (PVS) for prediction of outcome and therapy effectiveness in cardiac arrest (CA) survivors. We performed baseline PVS in 285 survivors of CA enrolled in the Cardiac Arrest Study Hamburg (CASH) and randomised to ICDs or AADs. Sustained ventricular arrhythmia (VA) was induced in 134 (47.0%) patients. We compared the outcomes of different subgroups based on response to baseline PVS and randomly assigned therapy. Patients were followed for a median of 55 months. The raw death rate was greater among inducible (51.3% [95% CI: 44.9-58.3%]) than non-inducible patients (28.8% [CI: 23.4-36.1%, p = 0.0003]). When challenged in a multivariate model, inducibility still had an independent power for predicting all-cause death (hazard ratio (HR), 1.5 [95% CI, 1.1-2.3], p = 0.041), but not sudden death (SD) (HR, 1.2 [95% CI, 0.7-3.6], p = 0.162). Subgroup analysis showed that, when compared to AADs, assignment to ICDs was associated with a lower risk of all-cause death (HR, 0.4 [95% CI, 0.1-0.9], p = 0.044) in patients with EF < or =0.35 and non-inducible arrhythmias, but not in other patient subgroups. In CA survivors, inducibility at baseline PVS is independently associated with an increased risk of all-cause death, but not SD. In addition, response to PVS may help to identify subgroups of patients who could most benefit from ICD.

  12. Implantable cardioverter-defibrillator programming and electrical storm: Results of the OBSERVational registry On long-term outcome of ICD patients (OBSERVO-ICD).

    Science.gov (United States)

    Guerra, Federico; Palmisano, Pietro; Dell'Era, Gabriele; Ziacchi, Matteo; Ammendola, Ernesto; Bonelli, Paolo; Patani, Francesca; Cupido, Claudio; Devecchi, Chiara; Accogli, Michele; Occhetta, Eraldo; Santangelo, Lucio; Biffi, Mauro; Boriani, Giuseppe; Capucci, Alessandro

    2016-10-01

    Electrical storm (ES) is defined as 3 or more episodes of ventricular fibrillation (VF) or ventricular tachycardia (VT) within 24 hours and is associated with increased cardiac and all-cause mortality. The purpose of this study was to test whether aggressive implantable cardioverter-defibrillator (ICD) programming can be associated with ES. The OBSERVational registry On long-term outcome of ICD patients (OBSERVO-ICD) is a multicenter, retrospective registry enrolling all consecutive patients undergoing ICD implantation from 2010 to 2012 in 5 Italian high-volume arrhythmia centers. Clinical history and risk factors were collected for all patients, as were ICD therapy-related variables such as detection zones and delays. The total number of arrhythmic episodes and therapies delivered by the ICD were collected through out-of-hospital visits and remote monitoring. The registry enrolled 1319 consecutive patients, of whom 62 (4.7%) experienced at least 1 ES during follow-up (median 39 months). Patients who experienced ES had a significantly lower VF detection zone (P = .002), more frequently had antitachycardia pacing therapies programmed off during capacitor charge (P = .001), and less frequently had an ICD set with delayed therapies for VT zones (P = .042) and VF zone (P = .036). Patients who experienced ES had a significantly higher incidence of death and heart failure-related death compared to patients with no ventricular arrhythmias and patients with unclustered VTs/VFs (P = .025 and P <.001, respectively). Patients with ES had a more aggressive ICD programming setup, including lower VF detection rates, shorter detection times, and no antitachycardia pacing therapies during capacitor charge. This kind of ICD programming potentially could increase the likelihood of ES and the related risk of death. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  13. Implantable cardioverter-defibrillators for treatment of sustained ventricular arrhythmias in patients with Chagas' heart disease: comparison with a control group treated with amiodarone alone.

    Science.gov (United States)

    Gali, Wagner L; Sarabanda, Alvaro V; Baggio, José M; Ferreira, Luís G; Gomes, Gustavo G; Marin-Neto, J Antônio; Junqueira, Luiz F

    2014-05-01

    Evidence is inconclusive concerning the benefit of implantable cardioverter-defibrillators (ICDs) for secondary prevention of mortality in patients with Chagas' heart disease (ChHD). The aim of this study was to compare the outcomes of ChHD patients with life-threatening ventricular arrhythmias (VAs), who were treated either with ICD implantation plus amiodarone or with amiodarone alone. The ICD group [76 patients; 48 men; age, 57 ± 11 years; left ventricular ejection fraction (LVEF), 39 ± 12%] and the historical control group treated with amiodarone alone (28 patients; 18 men; age, 54 ± 10 years; LVEF, 41 ± 10%) had comparable baseline characteristics, except for a higher use of beta-blockers in the ICD group (P < 0.0001). Amiodarone was also used in 90% of the ICD group. Therapy with ICD plus amiodarone resulted in a 72% reduced risk of all-cause mortality (P = 0.007) and a 95% reduced risk of sudden death (P = 0.006) compared with amiodarone-only therapy. The survival benefit of ICD was greatest in patients with LVEF < 40% (P = 0.01) and was not significant in those with LVEF ≥ 40% (P = 0.15). Appropriate ICD therapies occurred in 72% of patients and the rates of interventions were similar across patients with LVEF < 40% and ≥40%. Compared with amiodarone-only therapy, ICD implantation plus amiodarone reduced the risk of all-cause mortality and sudden death in ChHD patients with life-threatening VAs. Patients with LVEF < 40% derived significantly more survival benefit from ICD therapy. The majority of ICD-treated patients received appropriate therapies regardless of the LV systolic function.

  14. Prevalence, correlates, and temporal trends in antiarrhythmic drug use at discharge after implantable cardioverter defibrillator placement (from the National Cardiovascular Data Registry [NCDR]).

    Science.gov (United States)

    Dev, Sandesh; Peterson, Pamela N; Wang, Yongfei; Curtis, Jeptha P; Varosy, Paul D; Masoudi, Frederick A

    2014-01-15

    Patients with implantable cardioverter defibrillators (ICDs) can require antiarrhythmic drugs to manage arrhythmias and prevent device shocks. We sought to determine the prevalence, clinical correlates, and institutional variation in the use of antiarrhythmic drugs over time after ICD implantation. From the ICD Registry (2006 to 2011), we analyzed the trends in the use of antiarrhythmic agents prescribed at hospital discharge for patients undergoing first-time ICD placement. The patient, provider, and facility level variables associated with antiarrhythmic use were determined using multivariate logistic regression models. A median odds ratio was calculated to assess the hospital-level variation in the use of antiarrhythmic drugs. Of the cohort (n = 500,995), 15% had received an antiarrhythmic drug at discharge. The use of class III agents increased modestly (13.9% to 14.9%, p <0.01). Amiodarone was the most commonly prescribed drug (82%) followed by sotalol (10%). Among the subgroups, the greatest increase in prescribing was for patients who had received a secondary prevention ICD (26% in 2006% and 30% in 2011, p <0.01) or with a history of ventricular tachycardia (23% to 27%, p <0.01). The median odds ratio for antiarrhythmic prescription was 1.45, indicating that 2 randomly selected hospitals would have had a 45% difference in the odds of treating identical patients with an antiarrhythmic drug. In conclusion, antiarrhythmic drug use, particularly class III antiarrhythmic drugs, is common among ICD recipients at hospital discharge and varies by hospital, suggesting an influence from local treatment patterns. The observed hospital variation suggests a role for augmentation of clinical guidelines regarding the use of antiarrhythmic drugs for patients undergoing implantation of an ICD. Published by Elsevier Inc.

  15. Identifying patients with less potential to benefit from implantable cardioverter-defibrillator therapy: comparison of the performance of four risk scoring systems.

    Science.gov (United States)

    Kaura, Amit; Sunderland, Nicholas; Kamdar, Ravi; Petzer, Edward; McDonagh, Theresa; Murgatroyd, Francis; Dhillon, Para; Scott, Paul

    2017-08-01

    Patients at high non-sudden cardiac death risk may gain no significant benefit from implantable cardioverter-defibrillator (ICD) therapy. A number of approaches have been proposed to identify these patients, including single clinical markers and more complex scoring systems. The aims of this study were to use the proposed scoring systems to (1) establish how many current ICD recipients may be too high risk to derive significant benefit from ICD therapy and (2) evaluate how well the scoring systems predict short-term mortality in an unselected ICD cohort. We performed a single-centre retrospective observational study of all new ICD implants over 5 years (2009-2013). We used four published scoring systems (Bilchick, Goldenberg, Kramer and Parkash) and serum urea to identify new ICD recipients whose short-term predicted mortality risk was high. We evaluated how well the scoring systems predicted death. Over 5 years, there were 406 new implants (79% male, mean age 70 (60-76), 58% primary prevention). During a follow-up of 936 ± 560 days, 96 patients died. Using the scoring systems, the proportion of ICD recipients predicted to be at high short-term mortality risk were 5.9% (Bilchick), 34.7% (Goldenberg), 7.4% (Kramer), 21.4% (Parkash) and 25% (urea, cut-off of >9.28 mM). All four risk scores predicted mortality (P systems, a significant proportion of current ICD recipients are at high short-term mortality risk. Although all four scoring systems predicted mortality during follow-up, none significantly outperformed serum urea.

  16. Implantable defibrillator therapy: more than defibrillation...

    NARCIS (Netherlands)

    D.A.M.J. Theuns (Dominic)

    2005-01-01

    textabstractDuring the past 25 years, the implantable cardioverter-defibrillator (ICD) has evolved from the treatment of last resort to the gold standard for patients at high risk for life­threatening ventricular tachyarrhythmias. Patients at high risk include those who survived life-threatening ven

  17. Implantable defibrillator therapy: more than defibrillation...

    NARCIS (Netherlands)

    D.A.M.J. Theuns (Dominic)

    2005-01-01

    textabstractDuring the past 25 years, the implantable cardioverter-defibrillator (ICD) has evolved from the treatment of last resort to the gold standard for patients at high risk for life­threatening ventricular tachyarrhythmias. Patients at high risk include those who survived life-threatening

  18. Mechanical dispersion and global longitudinal strain by speckle tracking echocardiography: Predictors of appropriate implantable cardioverter defibrillator therapy in hypertrophic cardiomyopathy.

    Science.gov (United States)

    Candan, Ozkan; Gecmen, Cetin; Bayam, Emrah; Guner, Ahmet; Celik, Mehmet; Doğan, Cem

    2017-06-01

    In this study, we investigated whether mechanical dispersion which reflects electrical abnormality and other echocardiographic and clinic parameters predict appropriate ICD shock in patients undergone ICD implantation for hypertrophic cardiomyopathy. Sixty-three patients who received ICD implantation for primary or secondary prevention were included in the study. Patients' clinical, electrocardiographic, 2D classic, and speckle tracking echocardiographic data were collected. Mechanical dispersion was defined as the standard deviation of time to peak negative strain in 18 left ventricular segments. Appropriate ICD therapy was defined as cardioversion or defibrillation due to ventricular tachycardia or fibrillation. Patients were divided into two groups as occurrence or the absence of appropriate ICD therapy. A total of 17 (26.9%) patients were observed to have an appropriate ICD therapy during follow-up periods. In patients who performed appropriate ICD therapy, a larger left atrial volume index, higher sudden cardiac death (SCD)-Risk Score, longer mechanical dispersion, and decreased global longitudinal peak strain (GLPS) were observed. In multivariate logistic regression analysis, including (GLPS, mechanical dispersion, LAVi, and SCD-Risk Score) was used to determine independent predictors of occurrence of appropriate ICD therapy during the follow-up. Mechanical dispersion, GLPS, and SCD-Risk Score were found to be independent predictors of occurrence of appropriate ICD therapy. Mechanical dispersion, GLPS, and SCD-Risk Score were found to be predictive for appropriate ICD therapy in patients receiving ICD implantation. Readily measurable mechanical dispersion and GLPS could be helpful to distinguish patients at high risk who could optimally benefit from ICD therapy. © 2017, Wiley Periodicals, Inc.

  19. [Positive microvolt T-wave alternans as a marker of ventricular arrhythmia trigering during cardioverter-defibrillator implantation].

    Science.gov (United States)

    Wierzbowski, Robert; Michałkiewicz, Dariusz; Cholewa, Marian; Jacewicz, Katarzyna; Gniłka, Anna; Adamus, Jerzy

    2006-10-01

    Microvolt T-wave alternans (MTWA) is promising method for noninvasive assessment of arrhythmic risk, but its role hasn't established yet. The aim of this study was to establish the MTWA potency to predict the ventricular arrhythmia triggering during implantable cordioverter-defibrillator (ICD) implantation. Material and metods. The study group consisted of 21 patients, aged 63.0+/-8.0 years; EF was 38.0+/-12.8%. Seventeen of them had a history of myocardial infarction and 4 had non-ischemic cardiomyopathy. The reason for ICD implantation were secondary prevention due to nonfatal cardiac arrest caused by VF/VT in nineteen patients and in two patients ICD was implanted because of unexplained syncope and low EF (protocol of 50 Hz BURST and T SHOCK was applied. After ICD implantation the following tests were performed: ECG with HR, QRS and QTc evaluation, 24-hour ECG Holter monitoring with HRV assessment and MTWA evaluation during treadmill exercise test. Results. In the group with VT/VF induced by less aggressive protocol (EPS), group I (n = 10) MTWA was present in nine patients, in one the result of MTWA was indeterminate. In the group with VT/VF induced by more aggressive protocol, group II (n = 11) MTWA was present in four patients, indeterminate in four and absent in three. There was a significant (p = 0.017) difference between group I and II in the frequency of positive result of MTWA. There were no differences between the two groups according to time domain parameters of HRV such as SDNN, RMSSD and PNN50 and QTc. There was a significant difference between the two groups in time duration of QRS complexes, 118.9+/-14.7 vs. 105.6+/-11.5 accordingly (p more easily inducible by electrophysiologic study during ICD implantation. It is easier to induce ventricular arrhythmia when QRS complexes are wider, irrelevant to left ventricular dysfunction and autonomic function of the heart.

  20. Prediction of Appropriate Shocks Using 24-Hour Holter Variables and T-Wave Alternans After First Implantable Cardioverter-Defibrillator Implantation in Patients With Ischemic or Nonischemic Cardiomyopathy.

    Science.gov (United States)

    Seegers, Joachim; Bergau, Leonard; Expósito, Pascal Muñoz; Bauer, Axel; Fischer, Thomas H; Lüthje, Lars; Hasenfuß, Gerd; Friede, Tim; Zabel, Markus

    2016-07-01

    In patients treated with implantable cardioverter defibrillator (ICD), prediction of both overall survival and occurrence of shocks is important if improved patient selection is desired. We prospectively studied the predictive value of biomarkers and indexes of cardiac and renal function and spectral microvolt T-wave alternans testing and 24-hour Holter variables in a population who underwent first ICD implantation. Consecutive patients in sinus rhythm with ischemic or dilated cardiomyopathy scheduled for primary or secondary prophylactic ICD implantation were enrolled. Exercise microvolt T-wave alternans and 24-hour Holter for number of ventricular premature contractions (VPCs), deceleration capacity, heart rate variability, and heart rate turbulence were done. Death of any cause and first appropriate ICD shock were defined as end points. Over 33 ± 15 months of follow-up, 36 of 253 patients (14%) received appropriate shocks and 39 of 253 patients (15%) died. Only 3 of 253 patients (1%) died after receiving at least 1 appropriate shock. In univariate analyses, New York Heart Association class, ejection fraction, N-terminal pro brain-type natriuretic peptide (NT-proBNP), renal function, ICD indication, deceleration capacity, heart rate variability, and heart rate turbulence were predictive of all-cause mortality and VPC number and deceleration capacity predicted first appropriate shock. NT-proBNP (≥1,600 pg/ml) was identified as the only independent predictor of all-cause mortality (hazard ratio 3.0, confidence interval 1.3 to 7.3, p = 0.014). In contrast, VPC number predicted appropriate shocks (hazard ratio 2.3, confidence interval 1.0 to 5.5, p = 0.047) as the only independent risk marker. In conclusion, NT-proBNP is a strong independent predictor of mortality in a typical prospective cohort of newly implanted patients with ICD, among many electrocardiographic and clinical variables studied. Number of VPCs was identified as a predictor of appropriate shocks

  1. Is metal artefact reduction mandatory in cardiac PET/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

    Energy Technology Data Exchange (ETDEWEB)

    Ghafarian, Pardis [Shahid Beheshti University, Department of Radiation Medicine, Tehran (Iran, Islamic Republic of); Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Tehran University of Medical Sciences, Research Center for Science and Technology in Medicine, Tehran (Iran, Islamic Republic of); Aghamiri, S.M.R. [Shahid Beheshti University, Department of Radiation Medicine, Tehran (Iran, Islamic Republic of); Ay, Mohammad R. [Tehran University of Medical Sciences, Research Center for Science and Technology in Medicine, Tehran (Iran, Islamic Republic of); Tehran University of Medical Sciences, Department of Medical Physics and Biomedical Engineering, Tehran (Iran, Islamic Republic of); Tehran University of Medical Sciences, Research Institute for Nuclear Medicine, Tehran (Iran, Islamic Republic of); Rahmim, Arman [Johns Hopkins University, Department of Radiology, Baltimore, MD (United States); Schindler, Thomas H. [Geneva University, Cardiovascular Center, Nuclear Cardiology, Geneva (Switzerland); Ratib, Osman [Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Zaidi, Habib [Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Geneva University, Geneva Neuroscience Center, Geneva (Switzerland)

    2011-02-15

    Cardiac PET/CT imaging is often performed in patients with pacemakers and implantable cardioverter defibrillator (ICD) leads. However, metallic implants usually produce artefacts on CT images which might propagate to CT-based attenuation-corrected (CTAC) PET images. The impact of metal artefact reduction (MAR) for CTAC of cardiac PET/CT images in the presence of pacemaker, ICD and ECG leads was investigated using both qualitative and quantitative analysis in phantom and clinical studies. The study included 14 patients with various leads undergoing perfusion and viability examinations using dedicated cardiac PET/CT protocols. The PET data were corrected for attenuation using both artefactual CT images and CT images corrected using the MAR algorithm. The severity and magnitude of metallic artefacts arising from these leads were assessed on both linear attenuation coefficient maps ({mu}-maps) and attenuation-corrected PET images. CT and PET emission data were obtained using an anthropomorphic thorax phantom and a dedicated heart phantom made in-house incorporating pacemaker and ICD leads attached at the right ventricle of the heart. Volume of interest-based analysis and regression plots were performed for regions related to the lead locations. Bull's eye view analysis was also performed on PET images corrected for attenuation with and without the MAR algorithm. In clinical studies, the visual assessment of PET images by experienced physicians and quantitative analysis did not reveal erroneous interpretation of the tracer distribution or significant differences when PET images were corrected for attenuation with and without MAR. In phantom studies, the mean differences between tracer uptake obtained without and with MAR were 10.16{+-}2.1% and 6.86{+-}2.1% in the segments of the heart in the vicinity of metallic ICD or pacemaker leads, and were 4.43{+-}0.5% and 2.98{+-}0.5% in segments far from the leads. Although the MAR algorithm was able to effectively improve

  2. Behandling med implanterbar defibrillator

    DEFF Research Database (Denmark)

    Roseva-Nielsen, Natasha G; Svendsen, Jesper Hastrup

    2003-01-01

    About 20 years ago the first patient received an implantable cardioverter defibrillator (ICD), and since then the number of implants have increased dramatically. The ICD can terminate ventricular fibrillation and ventricular tachycardia. Studies of secondary prophylaxis show that ICD treatment can...

  3. Illness perceptions in patients with heart failure and an implantable cardioverter defibrillatorDimensional structure, validity, and correlates of the brief illness perception questionnaire in Dutch, French and German patients

    DEFF Research Database (Denmark)

    Timmermans, I.; Versteeg, H.; Meine, Mathias M

    2017-01-01

    and clinical and psychological correlates of the B-IPQ in Dutch, French and German patients with heart failure and an implantable cardioverter defibrillator (ICD). Method European heart failure patients (n=585) participating in the REMOTE-CIED study completed a set of questionnaires 1–2weeks post ICD.......69, with the ‘Consequences’ subscale being more internally consistent (α=0.80). Both the B-IPQ and its ‘Consequences’ subscale were significantly correlated with a number of psychological characteristics, but not with clinical characteristics. Multivariable logistic regression analysis indicated that threatening illness......-IPQ demonstrated good psychometric properties in Dutch, French and German patients with heart failure. Psychological factors were the most important correlates of patients' perceptions of heart failure, emphasizing the importance of targeting maladaptive illness perceptions in this population, due to their impact...

  4. Rationale, design, and baseline characteristics of the DANish randomized, controlled, multicenter study to assess the efficacy of Implantable cardioverter defibrillators in patients with non-ischemic Systolic Heart failure on mortality (DANISH)

    DEFF Research Database (Denmark)

    Thune, Jens Jakob; Pehrson, Steen; Nielsen, Jens Cosedis;

    2016-01-01

    BACKGROUND: The effect of an implantable cardioverter defibrillator (ICD) in patients with symptomatic systolic heart failure (HF) caused by coronary artery disease is well documented. However, the effect of primary prophylactic ICDs in patients with systolic HF not due to coronary artery disease...... by coronary artery disease have been randomized to receive an ICD or not, in addition to contemporary standard therapy. The primary outcome of the trial is time to all-cause death. Follow-up will continue until June 2016 with a median follow-up period of 5 years. Baseline characteristics show that enrolled...... (range, 21-84 years) at baseline, and 28% were women. CONCLUSION: DANISH will provide pertinent information about the effect on all-cause mortality of a primary prophylactic ICD in patients with symptomatic systolic HF not caused by coronary artery disease on contemporary standard therapy including CRT....

  5. Nursing care of patients receiving implantable cardioverter defibrillator implantation//%心脏转复除颤器植入术患者的护理

    Institute of Scientific and Technical Information of China (English)

    李燕林; 丁莉; 陈琴

    2011-01-01

    Objective To summarize the main nursing measures of implantable cardioverter defibrillator (ICD) implantation and to highlight the maneuvers of commonly seen complications. Methods Seven cases were successfully resuscitated after sudden cardiac death. They received ICD implantation. Before the procedure, patients were closely monitored with ECG and observed; after the procedure, patients had ECG and blood pressure monitoring, and the changes in heart rates and rhythm were closely observed.Nurses instructed patients to have good rest, gave diet guidance, helped them handle pain, and kept close eyes on vital signs and delivered health education. Nurses also handled complications and accidents timely. Results The 7 patients had a hospital stay of 1430 d. All patients were symptomatic in New York Heart Association Functional Class Ⅱ or Ⅲ at discharge. Patients were followed up 2-52 months. One cases died from lung infection and pump failure. The other six patients experienced 4 times of ICD shock delivery, 3 ventricular tachycardia, 1 supraventricular tachycardia. The quick-beating heart turned into sinus rhythm after shock delivery. One case developed hallucinations of electric shock; one case had effusion of the pouch. Both the above cases received symptomatic treatment. Conclusion The complications of ICD implantation be reduced by strengthening observation of vital signs of patients, giving scrupulous fundamental nursing and psychological nursing, and taking preventive precautions, which also lengthens the service life of the ICD system.%目的 总结植入型心脏转复除颤器(1CD)植入术的护理要点和常见并发症的处理方法.方法 对收治的心源性猝死抢救成功的7例患者行ICD植入术,术前加强心电监护及病情观察;术后持续心电、血压监测,尤其注意观察心率、心律的变化,做好休息与饮食、疼痛及生命体征护理和健康教育,及时处理常见并发症和意外.结果 7例患者住院14

  6. Subcutaneous Implantable Cardioverter-Defibrillator

    Science.gov (United States)

    ... Search Donate Circulation My alerts Sign In Join Facebook Twitter Home About this Journal Editorial Board General Statistics Circulation Doodle → Blip the Doodle Information for Advertisers Author Reprints Commercial Reprints Customer Service and Ordering ...

  7. Heart Rhythm UK position statement on clinical indications for implantable cardioverter defibrillators in adult patients with familial sudden cardiac death syndromes.

    Science.gov (United States)

    Garratt, Clifford J; Elliott, Perry; Behr, Elijah; Camm, A John; Cowan, Campbell; Cruickshank, Stephanie; Grace, Andrew; Griffith, Michael J; Jolly, Anne; Lambiase, Pier; McKeown, Pascal; O'Callagan, Peter; Stuart, Graham; Watkins, Hugh

    2010-08-01

    Whilst the decision regarding defibrillator implantation in a patient with a familial sudden cardiac death syndrome is likely to be most significant for any particular individual, the clinical decision-making process itself is complex and requires interpretation and extrapolation of information from a number of different sources. This document provides recommendations for adult patients with the congenital Long QT syndromes, Brugada syndrome, catecholaminergic polymorphic ventricular tachycardia, hypertrophic cardiomyopathy, and arrhythmogenic right ventricular cardiomyopathy. Although these specific conditions differ in terms of clinical features and prognosis, it is possible and logical to take an approach to determining a threshold for implantable cardioveter-defibrillator implantation that is common to all of the familial sudden cardiac death syndromes based on estimates of absolute risk of sudden death.

  8. The Clinical Application and Effect of Implantable Cardioverter Defibrillator(ICD)%经静脉植入埋藏式心脏复律除颤器的临床应用及效果观察

    Institute of Scientific and Technical Information of China (English)

    江自强

    2015-01-01

    Objective:to explore the clinical application and effect of implantable cardioverter defibrillator(icd). Methods:selecting and analyzing 80 cases of malignant ventricular arrhythmia, which are randomly divided into control group (treated with amiodarone) and treatment group(treated with the icd) . then comparing the effects. Results:the overall response rate(rr) of the treatment group is 95%, much higher than the other one(85%)(P0.05);yet after treatment, the heart rate of the treatment group is signiifcantly lower than the control group (P0.05);实验组治疗后心率,显著低于对照组(P<0.05);实验组治疗后Pr间期,显著高于对照组(P<0.05)。结论恶性室性心律失常采用静脉植入埋藏式心脏复律除颤器治疗效果理想,值得推广应用。

  9. Adding the implantable cardioverter-defibrillator to cardiac resynchronization therapy is associated with improved long-term survival in ischaemic, but not in non-ischaemic cardiomyopathy

    DEFF Research Database (Denmark)

    Witt, Christoffer Tobias; Kronborg, Mads Brix; Nohr, Ellen Aagaard;

    2015-01-01

    Hospital, Denmark from 2000 to 2010 were included. Baseline characteristics were retrieved from patient files and survival data were obtained from the Danish Civil Registration System. The primary outcome was all-cause mortality. The effect of ICD backup was estimated using Cox proportional hazards model...... to ischaemic cardiomyopathy (ICM) or non-ischaemic cardiomyopathy (NICM) treated with a CRT device with or without defibrillator backup. METHODS AND RESULTS: In this observational study, consecutive patients with an ejection fraction ≤35% and QRS width ≥120 ms receiving a CRT device at Aarhus University...

  10. MR Imaging in patients with cardiac pacemakers and implantable cardioverter defibrillators. Consensus paper of the German Cardiac Society and the German Roentgen Society; MR-Untersuchungen bei Patienten mit Herzschrittmachern und implantierbaren Kardioverter-Defibrillatoren. Konsensuspapier der Deutschen Gesellschaft fuer Kardiologie (DGK) und der Deutschen Roentgengesellschaft (DRG)

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, Torsten [DRK Krankenhaus, Neuwied (Germany). Klinik fuer Diagnostische und Interventionelle Radiologie; Bauer, Wolfgang [Deutsches Zentrum fuer Herzinsuffizienz Univ. Wuerzburg (Germany). Med. Klinik und Poliklinik I Univ. Klinikum Wuerzburg; Fischbach, Katharina [Universitaetsklinikum Magdeburg (Germany). Klinik fuer Radiologie und Nuklearmedizin; and others

    2017-03-15

    This joint consensus paper of the German Roentgen Society and the German Cardiac Society provides physical and electrophysiological background information and specific recommendations for the procedural management of patients with cardiac pacemakers (PM) and implantable cardioverter defibrillators (ICD) undergoing magnetic resonance (MR) imaging. The paper outlines the responsibilities of radiologists and cardiologists regarding patient education, indications, and monitoring with modification of MR sequences and PM/ICD reprogramming strategies being discussed in particular. The aim is to optimize patient safety and to improve legal clarity in order to facilitate the access of SM/ICD patients to MR imaging.

  11. Clinical observation and nursing of implantable cardioverter-defibrillator patients with oral anticoagulants in the peroperative period%ICD围术期未停口服抗凝药的临床观察和护理

    Institute of Scientific and Technical Information of China (English)

    孙丽; 冯婕; 陆敬平; 徐冬梅

    2012-01-01

    目的 探讨植入型心律转复除颤器(ICD)围术期未停口服抗凝药的临床观察和护理.方法 回顾ICD植入术35例患者,其中围术期未停抗凝药15例,总结护理要点和并发症的处理方法.结果 35例行ICD植入术患者均痊愈出院,随访患者无不良反应和并发症.结论 术前全面评估患者围术期是否停用或替代抗凝剂,同时做好患者教育及凝血监测工作,术后严密观察术区情况,发现异常及时处理.%Objective To explore the clinical manifestations and nursing of implantable car-dioverter- defibrillator (ICD) patients with oral anticoagulants in the peroperative period. Methods The clinical data of 35 ICD patients were reviewed. Among them, 15 patients continued the oral anticoagulants. The nursing highlights and the ways to deal with complications have been summarized. Results All patients were discharged from hospital with good recovery. Follow-up showed that there were no adverse reactions and complications. Conclusion Comprehensive assessment should be done to identify whether patients has discontinued oral anticoagulants or other substitutes in the perioperative period before surgery. Meanwhile, health education and coagulation should be properly managed. The progression of disease should be closely observed after surgery in case of e-mergencies.

  12. The economic impact of battery longevity in implantable cardioverter-defibrillators for cardiac resynchronization therapy: the hospital and healthcare system perspectives.

    Science.gov (United States)

    Landolina, Maurizio; Morani, Giovanni; Curnis, Antonio; Vado, Antonello; D'Onofrio, Antonio; Bianchi, Valter; Stabile, Giuseppe; Crosato, Martino; Petracci, Barbara; Ceriotti, Carlo; Bontempi, Luca; Morosato, Martina; Ballari, Gian Paolo; Gasparini, Maurizio

    2017-08-01

    Patients receiving cardiac resynchronization therapy defibrillators (CRT-Ds) are likely to undergo one or more device replacements, mainly for battery depletion. We assessed the economic impact of battery depletion on the overall cost of CRT-D treatment from the perspectives of the healthcare system and the hospital. We also compared devices of different generations and from different manufacturers in terms of therapy cost. We analysed data on 1792 CRT-Ds implanted in 1399 patients in 9 Italian centres. We calculated the replacement probability and the total therapy cost over 6 years, stratified by device generation and manufacturer. Public tariffs from diagnosis-related groups were used together with device prices and hospitalization costs. Generators were from 3 manufacturers: Boston Scientific (667, 37%), Medtronic (973, 54%), and St Jude Medical (152, 9%). The replacement probability at 6 years was 83 and 68% for earlier- and recent-generation devices, respectively. The need for replacement increased total therapy costs by more than 50% over the initial implantation cost for hospitals and by more than 30% for healthcare system. The improved longevity of recent-generation CRT-Ds reduced the therapy cost by ∼6% in both perspectives. Among recent-generation CRT-Ds, the replacement probability of devices from different manufacturers ranged from 12 to 70%. Consequently, the maximum difference in therapy cost between manufacturers was 40% for hospitals and 19% for the healthcare system. Differences in CRT-D longevity strongly affect the overall therapy cost. While the use of recent-generation devices has reduced the cost, significant differences exist among currently available systems.

  13. T-wave oversensing and inappropriate shocks in implantable cardioverter def ibrillators

    Institute of Scientific and Technical Information of China (English)

    GAO Lei; LU Cai-yi; WANG Shi-wen; XUE Qiao; YAN Wei; ZHOU Sheng-hua; CHEN Rui; LIU Peng; ZHAI Jin-yue

    2010-01-01

    @@ The implantable cardioverter defibrillator (ICD) represents today the treatment and prophylaxis of choice for patients at risk for sustained ventricular tachyarrhythmias.1"6 Accurate sensing of ventricular tachyarrhythmias is a critical aspect of the function of ICD.

  14. Painless Implanted Cardioverter Defibrillator Therapy: Have We Taken It Seriously?%植入式心脏复律除颤器的无痛性治疗:我们重视了吗?

    Institute of Scientific and Technical Information of China (English)

    宿燕岗

    2011-01-01

    Shocking therapy of implanted cardioverter defibrillator (ICD) has been criticized for its causing myocardium damage and inducing electrical storm. Instead the anti-tachycardia pacing (ATP) function has been introduced as the main pain-free therapy of ICD, which could terminate about 3/4 ventricular tachycardia ( VT) events, without raising the risk of syncope or accelerated VT. The main concerns of ATP include differential identification of supraventricular tachycardia, re-confirmation of charging, settings of fast VT zone, strategies for optimization, and ATP while or before charging etc. , and the parameters should be adjusted individually during follow up. More concern should be paid to pain-free ICD therapy in clinical practice.%电击治疗可导致包括心肌损伤及诱发植入式心脏复律除颤器电风暴等弊端.植入式心脏复律除颤器的无痛性治疗主要是指其抗心动过速起搏功能.抗心动过速起搏能成功终止约3/4的室性心动过速事件,不增加晕厥或加速室性心动过速.无痛性治疗的主要策略包括室上性心动过速的鉴别程序、充电时的再确认、设定快速室性心动过速区、抗心动过速起搏策略优化、充电中和充电前抗心动过速起搏等.这些参数设置应个体化并在随访中进行调整.应重视植入式心脏复律除颤器无痛性治疗在临床上的应用.

  15. The Cause Analysis and Countermeasures of Frequent Shocks in Patients with Implantable Cardioverter Defibrillator%埋藏式心脏除颤器患者频繁电击原因分析及对策

    Institute of Scientific and Technical Information of China (English)

    吴冬燕; 邢彩耐; 卢凤民; 付乃宽; 许静

    2014-01-01

    Objective To investigate the cause and countermeasures of frequent shocks in patients with implantable cardioverter defibrillators (ICD). Methods Eighty ICD patients with heart failure and malignant ventricular arrhythmias were followed up, including sixty-two male and eighteen female patients. There were 35 patients with single-chamber ICD, 23 with dual-chamber ICD and 22 with three-chamber ICD. Patients in this study were followed up for 1-6 years to analyze the reasons for ICD discharge. According to the specific circumstances, patients were treated. Results Twenty-three pa-tients in 80 patients suffered from shock treatment. Ten patients (12.5%) experienced frequent shocks. The causes of fre-quent shock included repeated episodes of ventricular tachycardia, invalid shock due to increased defibrillation threshold (DF) and false identification of the frequent episodes of paroxysmal ventricular tachycardia or arrhythmias. The management included the identification process adjustment of ventricular tachycardia and supraventricular tachycardia, increased num-bers of beats of ventricular tachycardia judgment and increase the basic pacing rate. The anti-arrhythmic drugs should be combinedly used, especially metoprolol and amiodarone. The ICD shock was significantly reduced after parameter optimiza-tion and anti-arrhythmic therapy. Conclusion The ICD shocks were effectively reduced with rational use of anti-arrhyth-mic drugs and valid ICD programming.%目的:探讨植入埋藏式心脏除颤器(ICD)的患者出现频繁放电的原因及处理方法。方法随访80例因心力衰竭或恶性室性心律失常植入ICD的患者,男62例,女18例,其中单腔ICD 35例,双腔ICD 23例,三腔ICD (CRTD)22例,随访1~6年,了解ICD的放电原因,并根据具体情况进行治疗。结果80例患者中有23例患者遭受电击,其中10例为频繁电击(24 h内电击≥3次或1年内电击≥5次),均为心脏猝死二级预防患者。

  16. Slow ventricular tachycardia in patients with implantable cardioverter defibrillator%植入植入型心律转复除颤器后慢频率室性心动过速的治疗策略

    Institute of Scientific and Technical Information of China (English)

    孙国建; 何浪; 陈宇宁; 欣明花; 付蕾; 钟诚; 沈法荣

    2016-01-01

    Objective This study aims to assess the incidence of slow ventricular tachycardia ( VT ) and its treatment strategies in implantable cardioverter defibrillator( ICD) patients. Methods All 353 patients with including single and dual-chamber ICD or cardiac resyncronization therapy defibrillator( CRT-D) were en-rolled in this study in Zhejiang Greentown Cardiovascular Hospital from January 2008 to December 2014. Pa-tients had a 3-zone detection configuration: monitoring non treatment(ventricular rate 120 to 180 bpm),anti-tachyarrhythmia pacing(ATP)-low energy shock zone(ventricular rate 180 to 200 bpm),and a ventricular fi-brillation zone.When VT burden was more than 10% and the ventricular rate was less than 160 bpm it needed to optimize the parameters to treat the slow VT. Patients were divided into group A ATP-low energy cardioverter groups(ATP1time-5 J-10 J-maximum energy shock);group B ATP-high energy(ATP 3 times-20 J-the largest energy). Results VT occurred in 102(29%)patients,slow VT occurred in 46(13.1%)patients.Parameters optimization was carried for slow VTs in 27(7. 6%)patients.One time ATP therapy success rate was 67% in group A,ATP+5 J success rate was 79%,ATP+5 J+10 J was 92%. Group B 3 times ATP success rate was 71%,ATP 3 times+20 J was 89%. Conclusion The slow VT had a high incidence in patients with ICD,espe-cially in patients who took up large doses of amiodarone andβreceptor blockers.For patients with heavier bur-den of slow VTs,ATP and small energy electric shock therapy may have greater benefit.%目的:探讨慢频率室性心动过速(室速)在植入植入型心律转复除颤器( ICD)患者中的发生率及治疗策略。方法入选浙江绿城心血管病医院心内科自2008年1月至2014年12月植入的除颤器[单、双腔ICD及心脏再同步治疗除颤器( CRT-D)]患者353例。所有一级预防和二级预防患者按既定不同方案设置参数。术后室速发作负荷≥10%且频率<160次/min定义为需优化参数治

  17. Role of implantable cardioverter defibrillator therapy in patients with long QT syndrome%植入型心律转复除颤器在长QT综合征患者中的应用

    Institute of Scientific and Technical Information of China (English)

    孙奇; 陈柯萍; 陈若菡; 华伟; 浦介麟; 张澍

    2008-01-01

    Objective To observe the role of implantable cardioverter defibrillator (ICD) therapy in patients with long QT syndrome. Methods ICD were planted in eight patients [4 men,4 women, mean age (27.3±25.9) years] with long QT syndrome. In the follow-up,the parameters of ICD were adjusted according to ICD therapy. Result During the follow-up of (27.3±25.9)months, ICD recorded 101 VT/VF episodes in 3 patients. With the traditional ICD programming,44 VF episodes were recorded. After the device parameters were adjusted according the VF episodes,57 VT and 2 VF episodes were recorded,most of them serf-terminated or terminated by low-energy shock. Electrical storm was presented in a patient,and we terminated it by increas-ing the base pacing rate. Inappropriate shocks due to T-wave oversensing were found in two patients,and it was avoided through adjusting the post-sensed Decay Delay. Conclusion Optimal device programming according to ICD therapy significantly decreases inappropriate ICD shocks and fewer unnecessary battery depletion and un-necessary shocks.%目的 总结阜外心血管病医院应用植入型心律转复除颤器(ICD)治疗长QT综合征(LQTS)患者的经验.方法 8例LQTS患者接受了ICD治疗,平均年龄(38.9±16.7)岁.在随访期间,根据具体情况,调整ICD的各项程控参数.结果 平均随访(27.3±25.9)个月,有3例患者出现了101次室性心动过速/心室颤动(VT/VF)事件.在出厂程控参数下,共记录到44次VF事件.重新设置VT/VF的识别及治疗参数后,共记录到57次VT事件,2次VF事件,大部分自行终止或经低能量转复成功.1例患者术后出现了电风暴,通过快速心室起搏,终止了尖端扭转性室性心动过速(Tdp)的反复发作.2例患者发生了因T波误感知导致的ICD误放电,通过延长感知灵敏度自动调整延迟,从而避免了T波误感知.结论 针对LQTS患者的发病特点,调整ICD的程控参数,可以提高疗效并减少ICD误放电.

  18. [The clinical practice guidelines of the Sociedad Española de Cardiología on the automatic implantable defibrillator].

    Science.gov (United States)

    Pérez-Villacastín, J; Carmona Salinas, J R; Hernández Madrid, A; Marín Huerta, E; Merino Llorens, J L; Ormaetxe Merodio, J; Moya i Mitjans, A

    1999-12-01

    Since the first implantation in man in 1980 implantable cardioverter defibrillator technology has greatly improved and the number of devices implanted has increased considerably every year. Non thoracotomy lead systems and biphasic shocks are now the approach of choice, offering an almost 100% success rate. This document reviews the recommendations for qualification of personnel and for the centres implanting and carrying out follow-ups on defibrillators. The current indications for the implantation of implantable cardioverter defibrillator are also addressed.

  19. Living with Your Implantable Cardioverter Defibrillator (ICD)

    Science.gov (United States)

    ... you take and when. Download a printable medication tracker . Learn more about arrhythmia medications in general. Understanding ... and dentists that you have an ICD. Follow activity instructions Follow the restrictions on activity and any ...

  20. Who Needs an Implantable Cardioverter Defibrillator?

    Science.gov (United States)

    ... of portable EKGs are Holter and event monitors . Holter and Event Monitors A Holter monitor records the heart's electrical activity for a ... EKG. An event monitor is similar to a Holter monitor. You wear an event monitor while doing ...

  1. Defibrillation for Ventricular Fibrillation: A Shocking Update.

    Science.gov (United States)

    Nichol, Graham; Sayre, Michael R; Guerra, Federico; Poole, Jeanne

    2017-09-19

    Cardiac arrest is defined as the termination of cardiac activity associated with loss of consciousness, of spontaneous breathing, and of circulation. Sudden cardiac arrest and sudden cardiac death (SCD) are terms often used interchangeably. Most patients with out-of-hospital cardiac arrest have shown coronary artery disease or symptoms during the hour before the event. Cardiac arrest is potentially reversible by cardiopulmonary resuscitation, defibrillation, cardioversion, cardiac pacing, or treatments targeted at the underlying disease (e.g., acute coronary occlusion). We restrict SCD hereafter to cardiac arrest due to ventricular fibrillation, including rhythms shockable by an automatic external defibrillator (AED), implantable cardioverter-defibrillator (ICD), or wearable cardioverter-defibrillator (WCD). We summarize the state of the art related to defibrillation in treating SCD, including a brief history of the evolution of defibrillation, technical characteristics of modern AEDs, strategies to improve AED access and increase survival, ancillary treatments, and use of ICDs or WCDs. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  2. Custo-efetividade de cardiodesfibriladores implantáveis no Brasil nos setores público e privado Cost-effectiveness of implantable cardioverter defibrillators in Brazil in the public and private sectors

    Directory of Open Access Journals (Sweden)

    Rodrigo Antonini Ribeiro

    2010-10-01

    Full Text Available FUNDAMENTO: Vários ensaios clínicos randomizados demonstraram a efetividade do cardiodesfibrilador implantável (CDI na redução de morte de pacientes com insuficiência cardíaca congestiva (ICC. Estudos de países desenvolvidos já avaliaram a custo-efetividade do CDI, porém as informações não são transferíveis para o Brasil. OBJETIVO: Avaliar a custo-efetividade do CDI em pacientes com ICC sob duas perspectivas: pública e saúde suplementar. MÉTODOS: Um modelo de Markov foi criado para analisar a relação de custo-efetividade incremental (RCEI do CDI, comparado à terapia convencional, em pacientes com ICC. Efetividade foi medida em anos de vida ajustados para qualidade (QALY. Na literatura, buscaram-se dados de efetividade e complicações. Custos foram extraídos das tabelas do SUS e de valores praticados pelos convênios, assim como médias de internações hospitalares. Análises de sensibilidade univariadas foram feitas em todas as variáveis do modelo. RESULTADOS: A RCEI foi de R$ 68.318/QALY no cenário público e R$ 90.942/QALY no privado. Esses valores são superiores aos sugeridos como pontos de corte pela Organização Mundial da Saúde, de três vezes o PIB per capita (R$ 40.545 no Brasil. Variáveis mais influentes na análise de sensibilidade foram: custo do CDI, intervalo de troca do gerador e efetividade do CDI. Em simulação de cenário semelhante ao MADIT-I, as relações foram de R$ 23.739/QALY no cenário público e R$ 33.592/QALY no privado. CONCLUSÃO: Para a população em geral com ICC, a relação de RCEI do CDI, tanto na perspectiva pública como na privada, é elevada. Resultados mais favoráveis ocorrem em pacientes com alto risco de morte súbita.BACKGROUND: Many randomized clinical trials have demonstrated the effectiveness of the implantable cardioverter-defibrillator (ICDs in death reduction of chronic heart failure (CHF patients. Some developed countries studies have evaluated its cost

  3. [Magnets, pacemaker and defibrillator: fatal attraction?].

    Science.gov (United States)

    Bergamin, C; Graf, D

    2015-05-27

    This article aims at clarifying the effects of a clinical magnet on pacemakers and Implantable Cardioverter Defibrillators. The effects of electromagnetic interferences on such devices, including interferences linked to electrosurgery and magnetic resonance imaging are also discussed. In general, a magnet provokes a distinctive effect on a pacemaker by converting it into an asynchronous mode of pacing, and on an Implantable Cardioverter Defibrillator by suspending its own antitachyarythmia therapies without affecting the pacing. In the operating room, the magnet has to be used cautiously with precisely defined protocols which respect the type of the device used, the type of intervention planned, the presence or absence of EMI and the pacing-dependency of the patient.

  4. Performance of the subcutaneous implantable cardioverter-defibrillator in patients with a primary prevention indication with and without a reduced ejection fraction versus patients with a secondary prevention indication

    NARCIS (Netherlands)

    L. Boersma (Lucas); C.S. Barr (Craig); M.C. Burke (Martin); A. Leon (Angel); D.A.M.J. Theuns (Dominic); J.M. Herre (John M.); R. Weiss (Ram); Kremers, M.S. (Mark S.); P. Neuzil (Petr); M. Husby (Michael); N. Carter (Nathan); T. Stivland (Timothy); M.R. Gold (Michael)

    2017-01-01

    textabstractBackground: The subcutaneous implantable defibrillator (S-ICD) provides an alternative to the transvenous ICD for the prevention of sudden cardiac death, but has not been well studied in the most commonly treated transvenous ICD patient population, namely, primary prevention (PP) patient

  5. Performance of the subcutaneous implantable cardioverter-defibrillator in patients with a primary prevention indication with and without a reduced ejection fraction versus patients with a secondary prevention indication

    NARCIS (Netherlands)

    L. Boersma (Lucas); C.S. Barr (Craig); M.C. Burke (Martin); A. Leon (Angel); D.A.M.J. Theuns (Dominic); J.M. Herre (John M.); R. Weiss (Ram); Kremers, M.S. (Mark S.); P. Neuzil (Petr); M. Husby (Michael); N. Carter (Nathan); T. Stivland (Timothy); M.R. Gold (Michael)

    2017-01-01

    textabstractBackground: The subcutaneous implantable defibrillator (S-ICD) provides an alternative to the transvenous ICD for the prevention of sudden cardiac death, but has not been well studied in the most commonly treated transvenous ICD patient population, namely, primary prevention (PP)

  6. 全自动远程家庭监测系统在植入心律转复除颤器患者中的应用%Home monitoring in patients with implantable cardioverter defibrillator or cardiac resynchronization therapy defibrillator

    Institute of Scientific and Technical Information of China (English)

    王凤梅; 李述峰; 王帆; 张烁

    2014-01-01

    目的 评价全自动远程家庭监测(HM)在植入心律转复除颤器(ICD)/心脏再同步治疗除颤器(CRT-D)患者中的应用.方法 随访23例植入了带有HM功能的ICD及CRT-D患者,分析HM所获得的日常信息和报警数据,观察其对系统相关事件、心律失常和心力衰竭(心衰)监测在内的临床相关事件的早期监测及临床干预的疗效.结果 对23例患者随访122~937(452.1±262.2)d,共接收报警信息1 991次,发现异常事件1 481次,其中96.4%是临床相关事件,1.5%为系统相关事件,无信息传输事件占2.1%.系统相关事件多为感知异常,其中发现左心室导线脱位1例.临床相关事件中心律失常报警事件占84.7%[室上性心律失常和心房颤动(房颤)事件较多],心衰报警事件占15.3%,以静息时心率升高及心脏再同步治疗心室起搏百分比降低为主.根据HM系统报警信息,电话联络患者65例次,优化参数11例次,指导调整药物治疗方案18例次,4例患者入院治疗.结论 对于植入ICD/CRT-D的患者,HM系统是一项必要的、安全可靠的远程监测方法,可以及时识别起搏系统相关异常、发现临床相关事件,可指导对患者进行早期临床干预,优化随访管理,提高患者生活质量.%Objective To evaluate the benefit of Home monitoring (HM) system in patients with implantable cardioverter defibrillator (ICD) or cardiac resynchronization therapy defibrillator(CRT-D).Methods Twentythree patients undergoing implantation of ICD or CRT-D with HM were enrolled,data automatically collected on a daily basis and alerts by HM were analyzed.Early detection and intervention effect of HM included arrhythmias or heart failure to clinical events and system related events.Results The mean follow-up duration was 122-937 (452.1±262.2) d,a total of 1 991 remote transmissions were received.Among these transmissions,1 481 abnormal events were reported,96.4% of events were clinical-related,and 1.5

  7. Psychological intervention following implantation of an implantable defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van den Broek, Krista C; Sears, Samuel F

    2007-01-01

    The medical benefits of the implantable cardioverter defibrillator (ICD) are unequivocal, but a subgroup of patients experiences emotional difficulties following implantation. For this subgroup, some form of psychological intervention may be warranted. This review provides an overview of current...... evidence on the efficacy of psychological intervention in ICD patients and recommendations for future research....

  8. Shock whilst gardening--implantable defibrillators & lawn mowers.

    Science.gov (United States)

    Von Olshausen, G; Lennerz, C; Grebmer, C; Pavaci, H; Kolb, C

    2014-02-01

    Electromagnetic interference with implantable cardioverter defibrillators (ICDs) can cause inappropriate shock delivery or temporary inhibition of ICD functions. We present a case of electromagnetic interference between a lawn mower and an ICD resulting in an inappropriate discharge of the device due to erroneous detection of ventricular fibrillation.

  9. Risk of chronic anxiety in implantable defibrillator patients

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; den Broek, Krista C van; Theuns, Dominic A M J

    2011-01-01

    Little is known about the prevalence of chronic anxiety in patients with an implantable cardioverter defibrillator (ICD). In a multi-center, prospective study, we examined 1) the prevalence of chronic anxiety (i.e., patients anxious at implantation and 12 months), and 2) predictors of chronic...... anxiety....

  10. Defibrillator Implantation in Patients with Nonischemic Systolic Heart Failure

    DEFF Research Database (Denmark)

    Køber, Lars; Thune, Jens J; Nielsen, Jens C

    2016-01-01

    BACKGROUND: The benefit of an implantable cardioverter-defibrillator (ICD) in patients with symptomatic systolic heart failure caused by coronary artery disease has been well documented. However, the evidence for a benefit of prophylactic ICDs in patients with systolic heart failure that is not d...... by Medtronic and others; DANISH ClinicalTrials.gov number, NCT00542945 .)....

  11. [Remarks on the guideline recommendations for cardioverter-defibrillator implantation for primary prevention of sudden cardiac Death in patients with severe ventricular dysfunction. Consensus Document of the Italian Association of Hospital Cardiologists (ANMCO)/Italian Society of Cardiology (SIC)/Italian Association of Arrhythmology and Cardiac Pacing (AIAC)].

    Science.gov (United States)

    Berisso, Massimo Zoni; Bongiorni, Maria Grazia; Curnis, Antonio; Calvi, Valeria; Catanzariti, Domenico; Gaita, Fiorenzo; Gulizia, Michele Massimo; Inama, Giuseppe; Landolina, Maurizio E; La Rovere, Maria Teresa; Mantovan, Roberto; Mascioli, Giosuè; Occhetta, Eraldo; Padeletti, Luigi; Salerno-Uriarte, Jorge A; Santini, Massimo; Sassone, Biagio; Senni, Michele; Zecchin, Massimo

    2013-11-01

    The indications for implantable cardioverter-defibrillator (ICD) therapy for the prevention of sudden cardiac death in patients with severe left ventricular dysfunction have rapidly expanded over the last 10 years on the basis of the very satisfying results of the numerous randomized clinical trials that have provided the framework for guidelines. However, the analysis of clinical practice in the real world has highlighted some important criticisms in the complex process of selection-management of those patients candidates for ICD therapy: 1) approximately one fourth of all ICD implantations is not justified by clinical evidence, 2) approximately one half of patients with an indication for ICD therapy do not undergo implantation, 3) the benefits from ICD therapy do not apply uniformly to all patients, 4) the relationship between the lifesaving benefit and the potential for harm of ICD therapy is still scarcely known. The main reason for this clinical scenario can be ascribed to the guideline recommendations that are based only on few standard cut-off criteria and therefore too generic and insufficiently detailed. This does not help cardiologists in their decision-making process, and results in fear, uncertainty, and sometimes emotional choices. The aim of this consensus document is to discuss current guideline recommendations and to provide the Italian cardiologists with the most updated information to optimize the selection of patients with severe left ventricular dysfunction who should receive ICD therapy.

  12. Impacto da parada cardíaca induzida nas funções cognitivas após o implante de cardiodesfibrilador Impacto de la parada cardíaca inducida en las funciones cognitivas después del implante de desfibrilador cardiaco Impact of induced cardiac arrest on cognitive function after implantation of a cardioverter-defibrillator

    Directory of Open Access Journals (Sweden)

    Mauro Prado da Silva

    2009-02-01

    1980 y se considera el tratamiento estándar para individuos bajo el riesgo de desarrollar arritmias ventriculares fatales. Con el interés de garantizar el funcionamiento adecuado del desfibrilador cardiaco, la energía necesaria para el término de la taquicardia ventricular o de la fibrilación ventricular, debe ser determinada durante el implante, siendo este procedimiento llamado test del límite de desfibrilación. Para la realización del test es necesario que se haga la inducción de la fibrilación ventricular, para que el aparato pueda identificar el ritmo cardíaco y tratarlo. El objetivo de este estudio fue verificar la incidencia de disfunción cognitiva 24 horas después del implante del desfibrilador cardiaco. MÉTODO: Se seleccionó una muestra consecutiva de 30 pacientes con indicación de colocación de desfibrilador cardiaco implantable (DCI y 30 pacientes con indicación de implante de marca-paso (MP. Los pacientes fueron evaluados en los siguientes momentos: 24 horas antes de la colocación del DCI o MP con ficha de evaluación preanestésica, Mini-Examen del Estado Mental (MEEM y Confusion Assessment Method (CAM. Durante el implante del DCI o MP fueron medidas las variables: número de paradas cardíacas y tiempo total de parada cardíaca. Veinte y cuatro horas después de la colocación del DCI o MP, se evaluaron las variables: MEEM y CAM. RESULTADOS: El test de Fisher mostró que no había diferencia de la frecuencia de puntuaciones alteradas del MEEM y del CAM entre los grupos antes y después de los implantes. El tiempo promedio de PCR 7,06, con máximos y mínimos de 15,1 y 4,7 segundos. CONCLUSIONES: La inducción de parada cardíaca durante el test del límite de desfibrilación, no conllevó a la disfunción cognitiva veinte y cuatro horas después del implante del desfibrilador cardiaco.BACKGROUND AND OBJECTIVES: Implantable cardioverter-defibrillators (ICD were introduced in clinical practice in 1980 and they are considered the standard

  13. Prophylactic implantable defibrillator in patients with arrhythmogenic right ventricular cardiomyopathy/dysplasia and no prior ventricular fibrillation or sustained ventricular tachycardia.

    LENUS (Irish Health Repository)

    Corrado, Domenico

    2010-09-21

    The role of implantable cardioverter-defibrillator (ICD) in patients with arrhythmogenic right ventricular cardiomyopathy\\/dysplasia and no prior ventricular fibrillation (VF) or sustained ventricular tachycardia is an unsolved issue.

  14. Effects of n-3 polyunsaturated fatty acids on malignant ventricular arrhythmias in patients with chronic heart failure and implantable cardioverter-defibrillators: A substudy of the Gruppo Italiano per lo Studio della Sopravvivenza nell'Insufficienza Cardiaca (GISSI-HF) trial.

    Science.gov (United States)

    Finzi, Andrea A; Latini, Roberto; Barlera, Simona; Rossi, Maria G; Ruggeri, Albarosa; Mezzani, Alessandro; Favero, Chiara; Franzosi, Maria G; Serra, Domenico; Lucci, Donata; Bianchini, Francesca; Bernasconi, Roberto; Maggioni, Aldo P; Nicolosi, Gianluigi; Porcu, Maurizio; Tognoni, Gianni; Tavazzi, Luigi; Marchioli, Roberto

    2011-02-01

    The antiarrhythmic effects of n-3 polyunsaturated fatty acids (n-3PUFA) in ischemic heart disease have been demonstrated; however, studies in patients surviving malignant ventricular arrhythmias of different etiologies treated with an implantable cardioverter-defibrillator (ICD) have given conflicting results. The purpose of this study was to assess the antiarrhythmic effect of n-3PUFA versus placebo in 566 patients with heart failure enrolled in the GISSI-HF trial who received an ICD for secondary or primary prevention of ventricular fibrillation (VF) or tachycardia (VT). Clinical data and arrhythmic event recordings extracted from the device memory were obtained. We tested the treatment effect by a multivariate Cox model adjusting for all clinical parameters associated with the primary end point defined as time to first appropriate ICD discharge for VT/VF. In the 566 patients with at least one recorded follow-up visit, 1363 VT and 316 VF episodes were terminated by ICD pacing or shock over a median follow-up of 928 days. The incidence of the primary end point event was 27.3% in the n-3PUFA group and 34.0% in the placebo group (adjusted hazard rate = 0.80, 95% CI 0.59-1.09, P = .152). Patients who received 1, 2 to 3, or >3 ICD discharges were 8.9%, 7.1%, and 11.1% in the n-3PUFA group, compared with slightly higher rates of 11.1%, 10.7%, and 12.1% in the placebo group (overall P = .30). Patients with the highest 3-month increase in plasma n-3PUFA had a somewhat lower incidence of arrhythmic events. The results of this study, though not statistically significant, support prior evidences of an antiarrhythmic effect of n-3PUFA in patients with ICD, although they leave open the issue of whether this effect leads to a survival benefit. Copyright © 2011 Mosby, Inc. All rights reserved.

  15. Pacemakers, defibrillators, and direct current cardioversion.

    Science.gov (United States)

    Sgarbossa, E B; Black, I W; Maloney, J D

    1993-01-01

    Technology for pacemakers and automatic implantable defibrillators continues to evolve. Emphasis is placed not only on preventing cardiac death, but also on improving symptoms and quality of life. The basic antibradycardia function of pacemakers is complemented by highly sophisticated rate-responsive capabilities. The search for the perfect physiologic sensor has not ended; potential limitations of the systems currently available are considered in this review. Reports on outcome with pacing in different populations are also discussed. There have been two important advances in automatic implantable defibrillators. One is the introduction of the third generation defibrillator in clinical investigation. A tiered therapy (including antitachycardia pacing, cardioversion, and defibrillation) can now be programmed in the same device, with the protection of back-up antibradycardia pacing. The other remarkable innovation is the expanding use of nonthoracotomy techniques for implantable cardioverter-defibrillator placement. This approach permits the avoidance of a subcutaneous patch electrode in some cases, the system being entirely transvenous. Finally, recent insights on external cardioversion for atrial arrhythmias are briefly reviewed.

  16. A patch in the pectoral position lowers defibrillation threshold.

    Science.gov (United States)

    Karasik, P; Solomon, A; Verdino, R; Moore, H; Rodak, D; Hannan, R; Fletcher, R

    1997-06-01

    Implantable pacemaker cardioverter defibrillators are now available with biphasic waveforms, which have been shown to markedly improve defibrillation thresholds (DFTs). However, in a number of patients the DFT remains high. Also, DFT may increase after implantation, especially if antiarrhythmic drugs are added. We report on the use of a subcutaneous patch in the pectoral position in 15 patients receiving a transvenous defibrillator as a method of easily reducing the DFT. A 660-mm2 patch electrode was placed beneath the generator in a pocket created on the pectoral fascia. The energy required for defibrillation was lowered by 56% on average, and the system impedance was lowered by a mean of 25%. This maneuver allowed all patients to undergo a successful implant with adequate safety margin.

  17. Evaluation and Management of Patients After Implantable Cardioverter-Defibrillator Shock%植入型心律转复除颤器放电后患者的诊治

    Institute of Scientific and Technical Information of China (English)

    Anil K. Gehi; Davendra Mehta; J. Anthony Gomes; 樊颖婕

    2007-01-01

    背景:多项大规模临床试验表明,植入型心律转复除颤器(implantable cardioverterdefibrillator,ICD)能够有效降低部分心脏病患者的死亡率.此后,ICD的植入量大幅增加,非电生理专科医生也因此经常会遇到实施ICD电转复除颤的患者.目的:在接受ICD电转复除颤的患者中评估诊疗策略.证据获取:采用下列医学主题词在PubMed和MEDLINE数据库中检索1990年1月至2006年9月发表的文献:defibrillators,implantable(除颤器,植入型);defibrillators,implantable/adverse effects(除颤器,植入型/不良反应);抗心律失常药物(anti-arrhythmic agents);电除颤(electric countershock);生活质量(quality of life);心动过速治疗(tachycardia therapy);运算法则(algorithm);室性心动过速/诊断(ventricular tachycardia/diagnosis);室上性心动过速/诊断(supraventricular tachycardia/diagnosis).排除病例报告,仅纳入英文文献.参考美国心脏病学会(American College of Cardiology)、美国心脏协会(American Heart Association)、心脏节律学会(Heart Rhythm Society)发布的建议、指南及所附参考文献,获得其他相关文献.证据综合:ICD恰当放电和误放电均有诸多原因.误放电可严重影响患者的生活质量.目前有多种ICD程控技术可有效控制ICD恰当放电和误放电的发生.采用抗心律失常药也能有效减少放电频率.结论:采用有效的ICD程控和抗心律失常药物可在保障ICD急救功能的同时减少ICD放电.对现有各种治疗手段有一个基本的了解是诊治接受ICD放电者的基础.

  18. Prevención primaria y secundaria de muerte súbita en un hospital de la Seguridad Social de Costa Rica: reporte del registro de pacientes con desfibrilador automático implantable, 2007-2011 Primary and secondary prevention of sudden cardiac death in a hospital of the social security system in Costa Rica: report from the registry of patients with implantable cardioverter-defibrillators, 2007-2011

    Directory of Open Access Journals (Sweden)

    Hugo Arguedas-Jiménez

    2013-03-01

    Full Text Available Justificación y objetivo: diversos estudios han demostrado la eficacia de los desfibriladores automáticos implantables en la prevención de la muerte súbita cardiaca. La aplicación de dicha evidencia debe ser evaluada mediante registros. El objetivo de este estudio fue describir las principales características epidemiológicas y clínicas y las complicaciones de los pacientes a quienes se les implanta un desfibrilador automático implantable en un hospital de tercer nivel en Costa Rica. Métodos: estudio observacional de cohorte, retrospectivo, que incluyó la totalidad de pacientes a quienes se les implantó un desfibrilador automático implantable en el hospital “Dr. Rafael Ángel Calderón Guardia” entre 2007 y 2011. Resultados: se incluyó 23 pacientes. La edad media fue de 55 ± 18 años. La cardiopatía isquémica fue la etiología más frecuente (10 pacientes. Veinte pacientes estaban en clase funcional I o II; la fracción de eyección media fue 0,38 ± 0,17. En los 18 pacientes el desfibrilador automático se implantó por prevención secundaria. Cinco pacientes presentaron una complicación temprana, todos ellos con dispositivos bicamerales: 2 hematomas menores, una disección del seno coronario, un desplazamiento del electrodo atrial derecho y un ictus cardioembólico. Hubo un total de 101 terapias (en 8 pacientes, de las cuales 94 fueron apropiadas (en 5 pacientes y 7 inapropiadas (en 3 pacientes; dos de estos últimos habían tenido episodios previos de fibrilación atrial. Conclusión: este registro muestra que la mayoría de los implantes de desfibriladores automáticos se realizan por prevención secundaria, con una alta tasa de terapias adecuadas y una baja tasa de terapias inadecuadas y de complicaciones; además, permite evaluar las indicaciones y las complicaciones asociadas con esta terapia.Aim: Several studies have demonstrated the efficacy of implantable cardioverter-defibrillators in the prevention of sudden

  19. Implantable cardioverter defibrillator for primary prevention of sudden cardiac death in the patients with chronic heart failure%植入型心律转复除颤器应用于慢性心力衰竭患者心脏性猝死一级预防的长期随访

    Institute of Scientific and Technical Information of China (English)

    王礼琳; 范洁; 赵金辅; 周启云; 张曦; 丁立群

    2012-01-01

    Objective To evaluate the clinical benefits of implantable cardioverter defibrillator for the primary prevention of sudden cardiac death(SCD) in the patients with chronic heart failure due to either ischemic or nonischemic dilated cardiomyopathy.Methods We retrospectively enrolled 56 patients who were diagnosed with chronic heart failure caused by either ischemic or nonischemic dilated cardiomyopathy from March 2002 to October 2011.Patients were graded NYHA class Ⅱ and Ⅲ,with left ventricular ejection fraction (LVEF) at 0.16 ~ 0.35 (0.29 ± 0.05).All patients voluntarily took standard medicine treatment of chronic heart failure and underwent implantable cardioverter defibrillator (ICD) implantation and initial parameters were set up.All enrolled patients were followed up at 1,3,and 6 months,and every 6 months thereafter.Results ICD was implanted via the subclavian vein successfully in all patients.During the follow-up period of 1 ~ 115 (44.05±35.16) months,11 patients had 26 episodes of ventricular fibrillation(19.6%),which were defibrillated successfully; 17 patients had 39 episodes of ventricular tachycardia(VT,30.4%),which were terminated successfully at 94.8%.Besides,failure of ICD termination of VT occurred in 1 patient for twice and the arrhythmia was self-terminated later.Inadequate shocks were found in 8 patients.Electrical storm occurred in 6 cases.ICD battery was exhausted in 16 patients and 10 patients accepted replacement of ICD.Eight patients died.Conclusions The patients with chronic heart failure due to either ischemic or nonischemic dilated cardiomyopathy are at high risk of SCD.ICD implantation can reduce the risk of SCD for the primary prevention.%目的 对植入型心律转复除颤器(ICD)应用于缺血性或非缺血性心肌病慢性心力衰竭患者心脏性猝死(SCD)一级预防价值进行长期随访观察.方法 2002年3月至2011年10月入选56例缺血性或非缺血性心肌病患者,心功能Ⅱ~Ⅲ级(NYHA

  20. Towards Low Energy Atrial Defibrillation

    Directory of Open Access Journals (Sweden)

    Philip Walsh

    2015-09-01

    Full Text Available A wireless powered implantable atrial defibrillator consisting of a battery driven hand-held radio frequency (RF power transmitter (ex vivo and a passive (battery free implantable power receiver (in vivo that enables measurement of the intracardiac impedance (ICI during internal atrial defibrillation is reported. The architecture is designed to operate in two modes: Cardiac sense mode (power-up, measure the impedance of the cardiac substrate and communicate data to the ex vivo power transmitter and cardiac shock mode (delivery of a synchronised very low tilt rectilinear electrical shock waveform. An initial prototype was implemented and tested. In low-power (sense mode, >5 W was delivered across a 2.5 cm air-skin gap to facilitate measurement of the impedance of the cardiac substrate. In high-power (shock mode, >180 W (delivered as a 12 ms monophasic very-low-tilt-rectilinear (M-VLTR or as a 12 ms biphasic very-low-tilt-rectilinear (B-VLTR chronosymmetric (6ms/6ms amplitude asymmetric (negative phase at 50% magnitude shock was reliably and repeatedly delivered across the same interface; with >47% DC-to-DC (direct current to direct current power transfer efficiency at a switching frequency of 185 kHz achieved. In an initial trial of the RF architecture developed, 30 patients with AF were randomised to therapy with an RF generated M-VLTR or B-VLTR shock using a step-up voltage protocol (50–300 V. Mean energy for successful cardioversion was 8.51 J ± 3.16 J. Subsequent analysis revealed that all patients who cardioverted exhibited a significant decrease in ICI between the first and third shocks (5.00 Ω (SD(σ = 1.62 Ω, p < 0.01 while spectral analysis across frequency also revealed a significant variation in the impedance-amplitude-spectrum-area (IAMSA within the same patient group (|∆(IAMSAS1-IAMSAS3[1 Hz − 20 kHz] = 20.82 Ω-Hz (SD(σ = 10.77 Ω-Hz, p < 0.01; both trends being absent in all patients that failed to cardiovert

  1. Clinical experience with a novel subcutaneous implantable defibrillator system in a single center

    NARCIS (Netherlands)

    L. Dabiri Abkenari (Lara); D.A.M.J. Theuns (Dominic); S.D.A. Valk (Suzanne); Y. van Belle (Yves); N. de Groot (Natasja); D. Haitsma (David); A. Muskens-Heemskerk (Agnes); T. Szili-Torok (Tamas); L.J.L.M. Jordaens (Luc)

    2011-01-01

    textabstractBackground: Implantable cardioverter-defibrillators (ICDs) reduce mortality in both primary and secondary prevention, but are associated with substantial short- and long-term morbidity. A totally subcutaneous ICD (S-ICD) system has been developed. We report the initial clinical

  2. Modulatory effects of cognitive behavior therapy on depression and anxiety in patients with implantable cardioverter defibrillator%认知行为疗法对心律转复除颤器植入患者抑郁焦虑症状的调节作用

    Institute of Scientific and Technical Information of China (English)

    祁述善; 方臻飞; 刘启明; 周胜华

    2005-01-01

    BACKGROUND: 60% of the patients receiving implantable cardioverter defibrillator(ICD) believe their quality of life has been improved. However,about 30% to 50% of the patients suffer from postoperative depression and anxiety; especially those patients receive electroconvulsive therapy (ECT).OBJECTIVE: To probe into the modulatory effects of cognitive behavior therapy(CBT) on depression and anxiety in patients with ICD.DESIGN: A retrospective case analysis based on ICD patients SETTING: Room of Cardiac Catheterization, Department of Cardiology, Xiangya Second Hospital PARTICIPANTS: The study was conducted in the Room of Cardiac Catheterization of the Department of Cardiology, Xiangya Second Hospital,Central South University from October 2000 to August 2001. Inclusive criteria: ICD patients that had ineffective medicine therapy for paroxysmal ventricular tachycardia and/or ventricular fibrillation complicated with cardiac syncope. Exclusive criteria: incoorperative patients or patients who unable to receive periodical follow up. A total of 6 patients were involved including 4 male and 2 female patients aged from 45 to 71 years old with an average age of (57.3 ± 2.4) years old. All of the patients received Micro Jewell Ⅱ 7223 ICD made by Medtronic Company. Diagnoses of basic disease:2 cases of coronary heart disease, 2 cases of right ventricular myocardial disease, 1 case of paroxysmal ventricular tachycardia due to unknown reason,and 1 case of Brugada syndrome.METHODS: "Morita therapy" technique was used. Patients were asked to transfer their spirit energies into feasible objectives of their real life, which would be helpful to the rapid improvement of their symptoms. symptom checklist-90(SCL-90) scale was used to evaluate the psychological symptoms before and after the therapy.MAIN OUTCOME MEASURES: Comparison of the scores gained in SCL-90 between before and after CBT.RESULTS: There were significant differences in the items of somatization,compulsion, sensitive

  3. 植入型心律转复除颤器在致心律失常性右心室心肌病患者中的应用%Implantable cardioverter defibrillator therapy in patients with arrhythmogenic right ventricular cardiomyopathy

    Institute of Scientific and Technical Information of China (English)

    孙奇; 陈柯萍; 陈若菡; 戴研; 华伟; 张澍

    2013-01-01

    Objective To evaluate the role of implantable cardioverter defibrillator(ICD) therapy in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC).Methods From Mar.2004 to Mar.2012,ARVC patients received ICD were enrolled in this study,and the clinical characteristics were collected.In the follow-up,we assessed the incidence,feature and ICD therapy in these patients.Results Eighteen patients were enrolled [12 men,6 women,mean age (46.4 ± 13.8) years].During the (46.6 ± 30.5) months followup period,ICD recorded 111 ventricular tachycardia (VT)/ventricular fibrillation (VF) episodes (1 VF,110 VT) in 6 patients.Among these,3 patients experienced 7 electrical storms(ES).Compare to patients without ICD therapy,C-reactive protein(CRP) level was higher in ICD therapy group.Among VT/VF episodes,12 episodes were terminated by shocks,99 episodes were terminated by anti-tachycardia pacing(ATP).Conclusions VT episodes were very common in ARVC patients,most of them could terminated by ATP.Repeated episodes of malignant arrhythmias in ARVC patients with ES were common.CRP level might be a significant predictor of appropriate ICD therapy in ARVC patients.%目的 总结阜外心血管病医院应用植入型心律转复除颤器(ICD)治疗致心律失常性右心室心肌病(ARVC)的经验.方法 入选我院2004年3月至2012年3月确诊并植入ICD的ARVC患者,收集临床资料,进行常规电话及门诊随诊.结果 共18例患者[男12例,女6例,平均年龄(46.4±13.8)岁]入选,平均随访(46.6±30.5)个月,有6例患者出现了111次室性心动过速(VT)/心室颤动(VF)事件,其中仅1次VF事件,其余均为VT事件,其中3例患者术后共出现了7次电风暴.ICD治疗组中的C反应蛋白(CRP)明显高于ICD未治疗组.111次VT/VF事件中,12次经电除颤终止心动过速,其余均通过抗心动过速起搏(ATP)终止了心动过速.结论 ARVC患者ICD植入后的VT/VF事件以VT为主,多数可经ATP终止;出现电风暴的ARVC患者

  4. Implantable cardioverter defibrillator therapy for primary prevention of sudden cardiac death in patients with heart failure%植入型心律转复除颤器在心力衰竭心脏性猝死一级预防中的作用初步观察

    Institute of Scientific and Technical Information of China (English)

    陈太波; 程康安; 高鹏; 刘博江; 范静波; 方全

    2010-01-01

    目的 总结我院应用植入型心律转复除颤器(ICD)进行心力衰竭心脏性猝死(SCD)一级预防的初步经验.方法 入选我院近3年因严重心力衰竭植入ICD进行SCD一级预防的患者,术后3个月进行ICD常规随访,以后每6个月随访1次.结果 入选患者22例,其中单腔ICD 15台,双腔ICD7台.22例患者随访时间3~28个月.记录ICD治疗事件21次,包括12次抗心动过速起搏(ATP)治疗和9次放电,只有1次ATP治疗患者具自觉症状.其中正确治疗(appropriate therapy)11次(52%)包括8次ATP治疗和3次放电,误治疗(inappropriate therapy)10次(48%).发生误治疗患者均为植入单腔ICD.结论 ICD可以安全有效地应用于心力衰竭SCD的一级预防,ICD误治疗事件是值得重视的临床问题,合理的ATP治疗可以提高患者的生活质量.%Objective To evaluate the effectiveness of implantable cardioverter defibrillator (ICD) therapy for primary prevention of sudden cardiac death (SCD) in patients with heart failure. Methods Twen-ty-two consecutive heart failure patients implanted with ICD for primary prevention of SCD in last 3 years were enrolled and followed up 3 months after implantation and every 6 months afterwards. Results Totally 22 cases were enrolled, including 15 with single-chamber ICD and 7 with dual-chamber ICD. Twenty-one ICD therapy events were documented during 3~28 months follow-up period, including 12 anti-tachycardia pacing (ATP) therapies and 9 shocks, and only one had symptoms. Eleven therapies (52%, 8 ATP therapies and 3 shocks) were classified as appropriate, and 10 (48%) as inappropriate. All inappropriate therapies were occurred in pa-tients implanted with single-chamber ICD. Conclusion In heart failure patients ICD for primary prevention of SCD was effective and appropriate. Relatively high incidence of inappropriate therapies remains a challenge. ATP therapy may improve the quality of life in ICD patients.

  5. Renal infarction due to atrial fibrillation after implantation of implantable cardioverter-defibrillator:a case report and review of literature%心房颤动患者植入植入式心脏复律除颤器术后肾梗死1例及文献复习

    Institute of Scientific and Technical Information of China (English)

    黄樱硕; 孙颖; 邢云利; 王翠英; 黄蔚; 李清清; 吴永全; 马清

    2014-01-01

    1例合并阵发性心房颤动(AF)的老年女性因室性心动过速(VT)而植入植入式心脏复律除颤器(ICD),围术期为避免出血风险,未予抗凝治疗,术后7d出现发热、腹痛,完善检查后诊断为肾梗死,立即开始规律抗凝治疗。目前针对AF患者植入心脏节律装置(CRD)围术期不同抗凝策略的安全性及有效性仍有争议。AF患者合并肾梗死相对少见,且该患者临床表现不典型,增加了早期诊断的难度。该病例带给我们的启示是:(1)对于卒中高危的AF患者,在植入CRD的围术期,抗凝治疗是必要的,但是采用何种抗凝策略尚有争议;(2)对于卒中高危的AF患者,在无抗凝的情况下,出现急腹症等表现时,应考虑腹腔脏器急性栓塞梗死的可能性。%We reported an elderly female (76 years old) accompanied with paroxysmal atrial fibrillation (AF) who underwent the implantation of implantable cardioverter-defibrillator (ICD) due to ventricular tachycardia (VT) in our department. No peri-operative anticoagulation was given to her in consideration of risk for hemorrhage. The patient was found to have fever and abdominal pain at the 7th day after surgery, and then right renal infarction was confirmed after diagnosis. Then the patient was given standard anticoagulant therapy. In present, it is a controversial issue on the efficacy and safety of anticoagulation strategy during perioperation of implantation of cardiac rhythm device (CRD). Renal infarction due to AF is relatively rare and the atypical clinical manifestations make early diagnosis for this patient more difficult. The revelation of this case includes:for patients with AF and high risk of stroke, anticoagulation therapy is necessary, but the strategy of anticoagulation remains controversial;for patients with AF and moderate risk of stroke, acute embolic infarction of abdominal organs should be taken into account when acute abdominal

  6. Longevity of the Subcutaneous Implantable Defibrillator Long-Term Follow-Up of the European Regulatory Trial Cohort

    NARCIS (Netherlands)

    Theuns, Dominic A. M. J.; Crozier, Ian G.; Barr, Craig S.; Hood, Margaret A.; Cappato, Riccardo; Knops, Reinoud E.; Maass, Alexander H.; Boersma, Lucas V. A.; Jordaens, Luc

    2015-01-01

    Background The recent advent of subcutaneous implantable cardioverter defibrillators (S-ICDs) has provided investigators with a safe and effective new therapy in patients at risk of sudden cardiac death. At present, no data are available with regard to the longevity of these new devices. This study

  7. Impact of left ventricular ejection fraction on occurrence of ventricular events in defibrillator patients with coronary artery disease

    NARCIS (Netherlands)

    B. Schaer (Beat); C. Sticherling (Christian); T. Szili-Torok (Tamas); S. Osswald (Stefan); L.J.L.M. Jordaens (Luc); D.A.M.J. Theuns (Dominic)

    2011-01-01

    textabstractAims Primary preventive implantable cardioverter defibrillator (ICD) therapy is indicated in patients with coronary artery disease (CAD) and left ventricular ejection fraction (LVEF) of ≤35, but some patients in the major trials had LVEF in the range of 3035. We hypothesized that these

  8. Phantom shocks in patients with implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Moons, Philip; Zwisler, Ann-Dorthe;

    2013-01-01

    of phantom shocks.METHODS AND RESULTS: The design was secondary explorative analyses of data from a randomized controlled trial. One hundred and ninety-six patients with first-time ICD implantation (79% male, mean age 58 years) were randomized (1 : 1) to either combined rehabilitation or a control group...

  9. Venous thromboembolism in patients with implantable cardioverter-defibrillators

    DEFF Research Database (Denmark)

    Pedersen, Susanne Bendesgaard; Hjortshøj, Søren Pihlkjær; Bøtker, Hans Erik;

    2016-01-01

    , overall and according to gender, age, Charlson Comorbidity Index score (no, moderate, or severe comorbidity), prior pacemaker or cardiac resynchronization therapy (CRT-D) implantation, and ICD type (single-chamber, dual-chamber, or CRT-D). We computed the risk of VTE within 3 months and 5 years...

  10. Web-Based Distress Management for Implantable Cardioverter Defibrillator Patients

    DEFF Research Database (Denmark)

    Habibović, Mirela; Denollet, Johan; Cuijpers, Pim

    2017-01-01

    distress post-ICD implantation. The WEB-based distress management program for ICD patients (WEBCARE) was developed to mitigate anxiety and depression and enhance health-related quality of life in ICD patients. This study investigates the 6- and 12-months outcomes. METHOD: A total of 289 consecutive ICD...... patients from 6 referral hospitals in the Netherlands were randomized to either the WEBCARE (n = 146) or usual care (n = 143) group. Patients in the WEBCARE group received an online, 12-weeks fixed, 6 lesson behavioral treatment based on problem solving therapy. Patients in the usual care group receive...... care as usual. RESULTS: Current findings show no significant difference on anxiety, depression or quality of life between the WEBCARE and Usual Care group at 6- and 12-months postimplantation. CONCLUSIONS: In this clinical trial of a Web-based behavioral intervention for ICD patients, the Web...

  11. How to Respond to an Implantable Cardioverter-Defibrillator Recall

    Science.gov (United States)

    ... the inherent limitation and the paradox of effective biotechnology; the more it is used, the more it ... build healthier lives, free of cardiovascular diseases and stroke. That single purpose drives all we do. The ...

  12. [Full dental rehabilitation of a patient with implantable cardioverter defibrillator].

    Science.gov (United States)

    Imre, Ildikó; Tóth, Zsuzsanna

    2012-06-01

    During dental rehabilitation of a patient with ICD, an upper telescope retained overdenture with acrylic baseplate and lower cantilever bridges were constructed. In the consultation following the anamnesis and the clinical examination, the cardiologist did not believe antibiotic profilaxis to be necessary, adding that it is advisable to avoid the use of ultrasonic depurator and electrocauter. Nowadays after saving the life the improving of patient's better quality of life is an important aspect. The risk of ICD-implantation is minimal however, not negligible, the patient can pursue a way of life free of limitation. According to the latest trends, the number of ICD-implantations will increase exponentially in the near future, due to the aging of the population, the simplification and safeness of implantation and the increase of patients who can be treated with the device. In case of arritmia or putative dysfunction, the latest ICD-s are able to send emergency alert to the arritmia centre with the help of an outer transmitter. Probably the system will completely change the follow-up of patients with ICD within the next few years, clinical researches of its efficiency are going on at present.

  13. Online cross-validation-based ensemble learning.

    Science.gov (United States)

    Benkeser, David; Ju, Cheng; Lendle, Sam; van der Laan, Mark

    2017-05-04

    Online estimators update a current estimate with a new incoming batch of data without having to revisit past data thereby providing streaming estimates that are scalable to big data. We develop flexible, ensemble-based online estimators of an infinite-dimensional target parameter, such as a regression function, in the setting where data are generated sequentially by a common conditional data distribution given summary measures of the past. This setting encompasses a wide range of time-series models and, as special case, models for independent and identically distributed data. Our estimator considers a large library of candidate online estimators and uses online cross-validation to identify the algorithm with the best performance. We show that by basing estimates on the cross-validation-selected algorithm, we are asymptotically guaranteed to perform as well as the true, unknown best-performing algorithm. We provide extensions of this approach including online estimation of the optimal ensemble of candidate online estimators. We illustrate excellent performance of our methods using simulations and a real data example where we make streaming predictions of infectious disease incidence using data from a large database. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  14. Defibrillation in children

    Directory of Open Access Journals (Sweden)

    Haskell Sarah

    2010-01-01

    Full Text Available Defibrillation is the only effective treatment for ventricular fibrillation (VF. Optimal methods for defibrillation in children are derived and extrapolated from adult data. VF occurs as the initial rhythm in 8-20% of pediatric cardiac arrests. This has fostered a new interest in determining the optimal technique for pediatric defibrillation. This review will provide a brief background of the history of defibrillation and a review of the current literature on pediatric defibrillation. The literature search was performed through PubMed, using the MeSH headings of cardiopulmonary resuscitation, defibrillation and electric countershock. The authors′ personal bibliographic files were also searched. Only published articles were chosen. The recommended energy dose has been 2 J/kg for 30 years, but recent reports may indicate that higher dosages may be more effective and safe. In 2005, the European Resuscitation Council recommended 4 J/kg as the initial dose, without escalation for subsequent shocks. Automated external defibrillators are increasingly used for pediatric cardiac arrest, and available reports indicate high success rates. Additional research on pediatric defibrillation is critical in order to be able to provide an equivalent standard of care for children in cardiac arrest and improve outcomes.

  15. Optimal Cross-Validation Split Ratio: Experimental Investigation

    DEFF Research Database (Denmark)

    Goutte, Cyril; Larsen, Jan

    1998-01-01

    Cross-validation is a common method for assessing the generalisation ability of a model in order to tune a regularisation parameter or otherhyper-parameters of a learning process. The use of cross-validation requires to set yet an additional parameter, the split rati. While a few texts haveinvest......Cross-validation is a common method for assessing the generalisation ability of a model in order to tune a regularisation parameter or otherhyper-parameters of a learning process. The use of cross-validation requires to set yet an additional parameter, the split rati. While a few texts...

  16. The NO Regular Defibrillation testing In Cardioverter Defibrillator Implantation (NORDIC ICD) trial

    DEFF Research Database (Denmark)

    Bänsch, Dietmar; Bonnemeier, Hendrik; Brandt, Johan

    2015-01-01

    was standardized across all participating centres. After inducing a fast ventricular tachycardia (VT) with a heart rate ≥240 b.p.m. or ventricular fibrillation (VF) with a low-energy T-wave shock, DF was attempted with an initial 15 J shock. If the shock reversed the VT or VF, DF testing was considered successful...

  17. Cross-validation criteria for SETAR model selection

    NARCIS (Netherlands)

    de Gooijer, J.G.

    2001-01-01

    Three cross-validation criteria, denoted C, C_c, and C_u are proposed for selecting the orders of a self-exciting threshold autoregressive SETAR) model when both the delay and the threshold value are unknown. The derivatioon of C is within a natural cross-validation framework. The crietion C_c is si

  18. Effect of digital cellular phones on tachyarrhythmia analysis of automated external defibrillators.

    Science.gov (United States)

    Kanz, Karl-Georg; Kay, Mike V; Biberthaler, Peter; Russ, Walter; Lackner, Christian K; Mutschler, Wolf

    2004-04-01

    Emergency services personnel, family members, laypersons or patients often carry and use mobile phones on sites of emergencies. As there are reported effects on implanted pacemakers and cardioverter defibrillators, the influence of digital cellular phones on automated external defibrillators was studied. Twelve automated external defibrillator models were bench tested for their correct decision to or not to advise a shock, while being exposed to electromagnetic interference from a handheld cellular phone with 2 W or a portable cellular phone with 8 W transmitting power. The phones were programmed by a special subscriber identity module card to maximum output power with a carrier frequency of 906.2 MHz. The tests were conducted with a burst frequency of 217 Hz in speech mode and 2-8 Hz in discontinuous transmitting exchange mode. The sensitivity and specificity of electrocardiogram analysis systems were tested, with shockable and non-shockable rhythms provided by an electrocardiogram simulator and on two human subjects with normal sinus rhythm. A total of 8640 tests were recorded, each automated external defibrillator was tested a total of 720 times. The automated external defibrillators demonstrated a sensitivity of 100% and a specificity of 100%, representing a positive likelihood ratio of 8641 and a negative likelihood ratio of 0.000. In this setting all automated external defibrillators analysed correctly even under worst-case testing conditions, and performed excellently without any single failure. In some devices, voice prompts were distorted beyond comprehension, as the coil of the automated external defibrillator speaker received the pulsed signals. Shock advisory systems of automated external defibrillators are not susceptible to electromagnetic interference of 900 MHz cellular phones. Voice prompts, however, could be distorted by the operation of nearby digital mobile phones. During automated external defibrillator training this issue needs to be addressed.

  19. A cross-validation package driving Netica with python

    Science.gov (United States)

    Fienen, Michael N.; Plant, Nathaniel G.

    2014-01-01

    Bayesian networks (BNs) are powerful tools for probabilistically simulating natural systems and emulating process models. Cross validation is a technique to avoid overfitting resulting from overly complex BNs. Overfitting reduces predictive skill. Cross-validation for BNs is known but rarely implemented due partly to a lack of software tools designed to work with available BN packages. CVNetica is open-source, written in Python, and extends the Netica software package to perform cross-validation and read, rebuild, and learn BNs from data. Insights gained from cross-validation and implications on prediction versus description are illustrated with: a data-driven oceanographic application; and a model-emulation application. These examples show that overfitting occurs when BNs become more complex than allowed by supporting data and overfitting incurs computational costs as well as causing a reduction in prediction skill. CVNetica evaluates overfitting using several complexity metrics (we used level of discretization) and its impact on performance metrics (we used skill).

  20. A Comparison of the Quality of Life of Patients With an Entirely Subcutaneous Implantable Defibrillator System Versus a Transvenous System (from the EFFORTLESS S-ICD Quality of Life Substudy)

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Mastenbroek, Mirjam H; Carter, Nathan;

    2016-01-01

    The first clinical results from the Evaluation of Factors Impacting Clinical Outcome and Cost Effectiveness of the subcutaneous implantable cardioverter defibrillator (EFFORTLESS S-ICD) Registry on the entirely S-ICD system are promising, but the impact of the S-ICD system on patients' quality of...

  1. Interference from a hand held radiofrequency remote control causing discharge of an implantable defibrillator.

    Science.gov (United States)

    Man, K C; Davidson, T; Langberg, J J; Morady, F; Kalbfleisch, S J

    1993-08-01

    A 46-year-old man with a history of sustained monomorphic ventricular tachycardia underwent an implantation of a third generation multiprogrammable implantable cardioverter defibrillator. One year post implant, while manipulating a remote control to a radiofrequency modulated toy car, the patient experienced a defibrillator discharge not preceded by an arrhythmia prodrome. Subsequent interrogation of the defibrillator revealed that a 34-joule shock had been delivered and had been preceded by RR intervals ranging from 141-406 msec, consistent with sensing lead noise. The remote control utilizes a 12-volt battery and has a carrier frequency of 75.95 MHz and a modulating frequency of 50 Hz. Evaluation of the remote control and defibrillator interaction revealed that the remote control was able to trigger tachyarrhythmia sensing and reproduce the clinical episode. Interference was present only when the remote control was within 8 cm of the pulse generator and at specific angles relative to the device and only when the antenna length was > 45 cm. Interference was eliminated when a ground wire was attached to the antenna and when an aluminium shield was placed between the pulse generator and the remote control. This case report suggests that patients with third generation multiprogrammable defibrillators should be cautioned against close contact with potential sources of electromagnetic interference, such as remote control units.

  2. Pacemaker, implanted cardiac defibrillator and irradiation: Management proposal in 2010 depending on the type of cardiac stimulator and prognosis and location of cancer; Pacemaker, defibrillateur et radiotherapie: propositions de conduite a tenir en 2010 en fonction du type de stimulateur cardiaque, du pronostic et du site du cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lambert, P. [Service d' anesthesie reanimation, hopital Nord, centre hospitalier universitaire de Saint-etienne, 42055 Saint-etienne cedex 2 (France); Da Costa, A. [Service de cardiologie, hopital Nord, centre hospitalier universitaire de Saint-etienne, 42055 Saint-etienne cedex 2 (France); Marcy, P.Y. [Departement de radiologie, centre Antoine-Lacassagne, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Universite Nice Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Kreps, S. [Service de radiotherapie Corad, centre regional universitaire de cancerologie Henry-S.-Kaplan, hopital Bretonneau-2, CHU de Tours, boulevard Tonnelle, 37000 Tours (France); Angellier, G.; Marcie, S.; Bondiau, P.Y. [Universite Nice Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Departement de radiotherapie oncologie, centre CyberKnife, centre Antoine-Lacassagne, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Briand-Amoros, C. [Service de radiotherapie, hopital europeen Georges-Pompidou, 20, rue Leblanc, 75015 Paris (France); Thariat, J. [Universite Nice Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Departement de radiotherapie oncologie, centre CyberKnife, centre Antoine-Lacassagne, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); IBDC CNRS UMR 6543, centre Antoine-Lacassagne, universite Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France)

    2011-06-15

    Ionizing radiation may interfere with electric components of pacemakers or implantable cardioverter defibrillators. The type, severity and extent of radiation damage to pacemakers, have previously been shown to depend on the total dose and dose rate. Over 300,000 new cancer cases are treated yearly in France, among which 60% are irradiated in the course of their disease. One among 400 of these patients has an implanted pacemaker or defibrillator. The incidence of pacemaker and implanted cardioverter defibrillator increases in an ageing population. The oncologic prognosis must be weighted against the cardiologic prognosis in a multidisciplinary and transversal setting. Innovative irradiation techniques and technological sophistications of pacemakers and implantable cardioverter-defibrillators (with the introduction of more radiosensitive complementary metal-oxide-semiconductors since 1970) have potentially changed the tolerance profiles. This review of the literature studied the geometric, dosimetric and radiobiological characteristics of the radiation beams for high energy photons, stereotactic irradiation, proton-therapy. Standardized protocols and radiotherapy optimization (particle, treatment fields, energy) are advisable in order to improve patient management during radiotherapy and prolonged monitoring is necessary following radiation therapy. The dose received at the pacemaker/heart should be calculated. The threshold for the cumulated dose to the pacemaker/implantable cardioverter-defibrillator (2 to 5 Gy depending on the brand), the necessity to remove/displace the device based on the dose-volume histogram on dosimetry, as well as the use of lead shielding and magnet are discussed. (authors)

  3. Single-coil and dual-coil defibrillator leads and association with clinical outcomes in a complete Danish nationwide ICD cohort

    DEFF Research Database (Denmark)

    Larsen, Jacob M; Hjortshøj, Søren P; Nielsen, Jens C;

    2016-01-01

    BACKGROUND: The best choice of defibrillator lead in patients with routine implantable cardioverter-defibrillator (ICD) is not settled. Traditionally, most physicians prefer dual-coil leads but the use of single-coil leads is increasing. OBJECTIVE: The purpose of this study was to compare clinical...... outcomes in patients with single- and dual-coil leads. METHODS: All 4769 Danish patients 18 years or older with first-time ICD implants from 2007 to 2011 were included from the Danish Pacemaker and ICD Register. Defibrillator leads were 38.9% single-coil leads and 61.1% dual-coil leads. The primary end...... point was all-cause mortality. Secondary end points were lowest successful energy at implant defibrillation testing, first shock failure in spontaneous arrhythmias, structural lead failure, and lead extraction outcomes. RESULTS: Single-coil leads were associated with lower all-cause mortality...

  4. Economic impact of longer battery life of cardiac resynchronization therapy defibrillators in Sweden

    Directory of Open Access Journals (Sweden)

    Gadler F

    2016-10-01

    Full Text Available Fredrik Gadler,1 Yao Ding,2 Nathalie Verin,3 Martin Bergius,4 Jeffrey D Miller,5 Gregory M Lenhart,5 Mason W Russell5 1Department of Cardiology, Karolinska University Hospital, Stockholm, Sweden; 2Truven Health Analytics, an IBM Company, Bethesda, MD, USA; 3Boston Scientific Corporation, Hemel Hempstead, Hertfordshire, UK; 4Boston Scientific Nordic AB, Helsingborg, Sweden; 5Truven Health Analytics, an IBM Company, Cambridge, MA, USA Objective: The objective of this study was to quantify the impact that longer battery life of cardiac resynchronization therapy defibrillator (CRT-D devices has on reducing the number of device replacements and associated costs of these replacements from a Swedish health care system perspective.Methods: An economic model based on real-world published data was developed to estimate cost savings and avoided device replacements for CRT-Ds with longer battery life compared with devices with industry-standard battery life expectancy. Base-case comparisons were performed among CRT-Ds of three manufacturers – Boston Scientific Corporation, St. Jude Medical, and Medtronic – over a 6-year time horizon, as per the available clinical data. As a sensitivity analysis, we evaluated CRT-Ds as well as single-chamber implantable cardioverter defibrillator (ICD-VR and dual-chamber implantable cardioverter defibrillator (ICD-DR devices over a longer 10-year period. All costs were in 2015 Swedish Krona (SEK discounted at 3% per annum.Results: Base-case analysis results show that up to 603 replacements and up to SEK 60.4 million cumulative-associated costs could be avoided over 6 years by using devices with extended ­battery life. The pattern of savings over time suggests that savings are modest initially but increase rapidly beginning in the third year of follow-up with each year’s cumulative savings two to three times the previous year. Evaluating CRT-D, ICD-VR, and ICD-DR devices together over a longer 10-year period, the

  5. TASER conducted electrical weapons and implanted pacemakers and defibrillators.

    Science.gov (United States)

    Vanga, Subba R; Bommana, Sudharani; Kroll, Mark W; Swerdlow, Charles; Lakkireddy, Dhanunjaya

    2009-01-01

    Conducted electrical weapons (CEW) have generated controversy in recent years regarding their effect on heart rhythm and on their suspected interaction with implanted devices such as the pacemakers and ICDs (implantable cardioverter defibrillators). We review the current evidence available on device interactions and pre-sent a new case series of 6 patients. We used the available case reports and animal studies on TASER or CEW related publications in PubMed. Oversensing of TASER CEW discharges may cause noise reversion pacing in pacemakers and inappropriate detection of VF in ICDs. The nominal 5-second discharge is sufficiently short that neither clinically significant inhibition of bradycardia pacing nor inappropriate ICD shocks have been reported. Current evidence indicates that CEW discharges do not have adverse effects on pacemakers and ICDs.

  6. Defibrillator Implantation in Patients with Nonischemic Systolic Heart Failure

    DEFF Research Database (Denmark)

    Køber, Lars; Thune, Jens J; Nielsen, Jens C

    2016-01-01

    BACKGROUND: The benefit of an implantable cardioverter-defibrillator (ICD) in patients with symptomatic systolic heart failure caused by coronary artery disease has been well documented. However, the evidence for a benefit of prophylactic ICDs in patients with systolic heart failure that is not due.......6%) in the control group (P=0.29). CONCLUSIONS: In this trial, prophylactic ICD implantation in patients with symptomatic systolic heart failure not caused by coronary artery disease was not associated with a significantly lower long-term rate of death from any cause than was usual clinical care. (Funded...... to coronary artery disease has been based primarily on subgroup analyses. The management of heart failure has improved since the landmark ICD trials, and many patients now receive cardiac resynchronization therapy (CRT). METHODS: In a randomized, controlled trial, 556 patients with symptomatic systolic heart...

  7. Benchmarking protein classification algorithms via supervised cross-validation

    NARCIS (Netherlands)

    Kertész-Farkas, A.; Dhir, S.; Sonego, P.; Pacurar, M.; Netoteia, S.; Nijveen, H.; Kuzniar, A.; Leunissen, J.A.M.; Kocsor, A.; Pongor, S.

    2008-01-01

    Development and testing of protein classification algorithms are hampered by the fact that the protein universe is characterized by groups vastly different in the number of members, in average protein size, similarity within group, etc. Datasets based on traditional cross-validation (k-fold, leave-o

  8. [Clinical development of the automatic implantable defibrillator over 35 years: A success story].

    Science.gov (United States)

    Steinbeck, G

    2015-06-01

    After 12 years of development and experimental evaluation, the first automatic implantable cardioverter-defibrillator (ICD) was implanted in man on February 4, 1980. This overview describes the technical and functional developments over 35 years from a simple shock-box, weighing 292 g, to the sophisticated 80 g device of today, delivering graded therapy to sustained ventricular arrhythmias and biventricular stimulation to treat heart failure. Finally, a special tribute is given to Michel Mirowski, one of the inventors of the ICD, as scientist and physician dedicated to patient care.

  9. Case report: use caution when applying magnets to pacemakers or defibrillators for surgery.

    Science.gov (United States)

    Schulman, Peter M; Rozner, Marc A

    2013-08-01

    The application of a magnet to a pacemaker (intended to cause asynchronous pacing) or implanted cardioverter defibrillator (intended to prevent shocks) during surgery without a clear understanding of actual magnet function(s) or precautions can have unexpected, untoward, or harmful consequences. In this report, we present 3 cases in which inadequate assessment of cardiac implanted electronic device (CIED) function, coupled with magnet application, contributed to or resulted in inappropriate antitachycardia pacing or shocks, CIED damage, or patient injury. Although these cases might be rare, they reinforce the need for a timely, detailed preoperative review of CIED function and programming as recommended by the American Society of Anesthesiologists and the Heart Rhythm Society.

  10. Benchmarking protein classification algorithms via supervised cross-validation.

    Science.gov (United States)

    Kertész-Farkas, Attila; Dhir, Somdutta; Sonego, Paolo; Pacurar, Mircea; Netoteia, Sergiu; Nijveen, Harm; Kuzniar, Arnold; Leunissen, Jack A M; Kocsor, András; Pongor, Sándor

    2008-04-24

    Development and testing of protein classification algorithms are hampered by the fact that the protein universe is characterized by groups vastly different in the number of members, in average protein size, similarity within group, etc. Datasets based on traditional cross-validation (k-fold, leave-one-out, etc.) may not give reliable estimates on how an algorithm will generalize to novel, distantly related subtypes of the known protein classes. Supervised cross-validation, i.e., selection of test and train sets according to the known subtypes within a database has been successfully used earlier in conjunction with the SCOP database. Our goal was to extend this principle to other databases and to design standardized benchmark datasets for protein classification. Hierarchical classification trees of protein categories provide a simple and general framework for designing supervised cross-validation strategies for protein classification. Benchmark datasets can be designed at various levels of the concept hierarchy using a simple graph-theoretic distance. A combination of supervised and random sampling was selected to construct reduced size model datasets, suitable for algorithm comparison. Over 3000 new classification tasks were added to our recently established protein classification benchmark collection that currently includes protein sequence (including protein domains and entire proteins), protein structure and reading frame DNA sequence data. We carried out an extensive evaluation based on various machine-learning algorithms such as nearest neighbor, support vector machines, artificial neural networks, random forests and logistic regression, used in conjunction with comparison algorithms, BLAST, Smith-Waterman, Needleman-Wunsch, as well as 3D comparison methods DALI and PRIDE. The resulting datasets provide lower, and in our opinion more realistic estimates of the classifier performance than do random cross-validation schemes. A combination of supervised and

  11. Defibrillator implantation early after myocardial infarction.

    Science.gov (United States)

    Steinbeck, Gerhard; Andresen, Dietrich; Seidl, Karlheinz; Brachmann, Johannes; Hoffmann, Ellen; Wojciechowski, Dariusz; Kornacewicz-Jach, Zdzisława; Sredniawa, Beata; Lupkovics, Géza; Hofgärtner, Franz; Lubinski, Andrzej; Rosenqvist, Mårten; Habets, Alphonsus; Wegscheider, Karl; Senges, Jochen

    2009-10-08

    The rate of death, including sudden cardiac death, is highest early after a myocardial infarction. Yet current guidelines do not recommend the use of an implantable cardioverter-defibrillator (ICD) within 40 days after a myocardial infarction for the prevention of sudden cardiac death. We tested the hypothesis that patients at increased risk who are treated early with an ICD will live longer than those who receive optimal medical therapy alone. This randomized, prospective, open-label, investigator-initiated, multicenter trial registered 62,944 unselected patients with myocardial infarction. Of this total, 898 patients were enrolled 5 to 31 days after the event if they met certain clinical criteria: a reduced left ventricular ejection fraction ( or = 150 beats per minute) during Holter monitoring (criterion 2: 208 patients), or both criteria (88 patients). Of the 898 patients, 445 were randomly assigned to treatment with an ICD and 453 to medical therapy alone. During a mean follow-up of 37 months, 233 patients died: 116 patients in the ICD group and 117 patients in the control group. Overall mortality was not reduced in the ICD group (hazard ratio, 1.04; 95% confidence interval [CI], 0.81 to 1.35; P=0.78). There were fewer sudden cardiac deaths in the ICD group than in the control group (27 vs. 60; hazard ratio, 0.55; 95% CI, 0.31 to 1.00; P=0.049), but the number of nonsudden cardiac deaths was higher (68 vs. 39; hazard ratio, 1.92; 95% CI, 1.29 to 2.84; P=0.001). Hazard ratios were similar among the three groups of patients categorized according to the enrollment criteria they met (criterion 1, criterion 2, or both). Prophylactic ICD therapy did not reduce overall mortality among patients with acute myocardial infarction and clinical features that placed them at increased risk. (ClinicalTrials.gov number, NCT00157768.) 2009 Massachusetts Medical Society

  12. Optimizing defibrillation waveforms for ICDs.

    Science.gov (United States)

    Kroll, Mark W; Swerdlow, Charles D

    2007-04-01

    While no simple electrical descriptor provides a good measure of defibrillation efficacy, the waveform parameters that most directly influence defibrillation are voltage and duration. Voltage is a critical parameter for defibrillation because its spatial derivative defines the electrical field that interacts with the heart. Similarly, waveform duration is a critical parameter because the shock interacts with the heart for the duration of the waveform. Shock energy is the most often cited metric of shock strength and an ICD's capacity to defibrillate, but it is not a direct measure of shock effectiveness. Despite the physiological complexities of defibrillation, a simple approach in which the heart is modeled as passive resistor-capacitor (RC) network has proved useful for predicting efficient defibrillation waveforms. The model makes two assumptions: (1) The goal of both a monophasic shock and the first phase of a biphasic shock is to maximize the voltage change in the membrane at the end of the shock for a given stored energy. (2) The goal of the second phase of a biphasic shock is to discharge the membrane back to the zero potential, removing the charge deposited by the first phase. This model predicts that the optimal waveform rises in an exponential upward curve, but such an ascending waveform is difficult to generate efficiently. ICDs use electronically efficient capacitive-discharge waveforms, which require truncation for effective defibrillation. Even with optimal truncation, capacitive-discharge waveforms require more voltage and energy to achieve the same membrane voltage than do square waves and ascending waveforms. In ICDs, the value of the shock output capacitance is a key intermediary in establishing the relationship between stored energy-the key determinant of ICD size-and waveform voltage as a function of time, the key determinant of defibrillation efficacy. The RC model predicts that, for capacitive-discharge waveforms, stored energy is minimized

  13. Cross-validation model assessment for modular networks

    CERN Document Server

    Kawamoto, Tatsuro

    2016-01-01

    Model assessment of the stochastic block model is a crucial step in identification of modular structures in networks. Although this has typically been done according to the principle that a parsimonious model with a large marginal likelihood or a short description length should be selected, another principle is that a model with a small prediction error should be selected. We show that the leave-one-out cross-validation estimate of the prediction error can be efficiently obtained using belief propagation for sparse networks. Furthermore, the relations among the objectives for model assessment enable us to determine the exact cause of overfitting.

  14. Cross-Validation, Bootstrap, and Support Vector Machines

    Directory of Open Access Journals (Sweden)

    Masaaki Tsujitani

    2011-01-01

    Full Text Available This paper considers the applications of resampling methods to support vector machines (SVMs. We take into account the leaving-one-out cross-validation (CV when determining the optimum tuning parameters and bootstrapping the deviance in order to summarize the measure of goodness-of-fit in SVMs. The leaving-one-out CV is also adapted in order to provide estimates of the bias of the excess error in a prediction rule constructed with training samples. We analyze the data from a mackerel-egg survey and a liver-disease study.

  15. Living with life insurance: a qualitative analysis of the experience of male implantable defibrillator recipients in Spain.

    Science.gov (United States)

    Palacios-Ceña, Domingo; Losa Iglesias, Marta E; Losa, Marta E; Fernández-de-Las-Peñas, César; Salvadores-Fuentes, Paloma

    2011-07-01

    The implantation of defibrillators should not be studied simply on the basis of clinical improvement or quality of life: it is also important to understand the significance, which the recipients attach to the defibrillator and their experiences with it. The aim of this work was, therefore, to determine the experience of Spanish implantable defibrillator recipients. A qualitative phenomenological study. Purposeful sampling of male implantable defibrillator recipients older than 18 years of age attended at the defibrillator consultancy at the Hospital Fuenlabrada or belonging to the Heart Patients' Association (Asociación de Pacientes Coronarios, APACOR). A secondary, theoretical sampling was also carried out to gain a more in-depth understanding of certain aspects identified in the first sampling, such as living with the discharges and difficulties during sexual activity. Data were collected using unstructured and semi-structured questionnaires and applying a question guide, field notes and the recipients' personal diaries/letters. Data collection was terminated once theoretical saturation was reached. Data were analysed using the Giorgi method. Finally, the seven themes, which showed what it means to be an implantable cardioverter-defibrillator recipient, were described. The defibrillator is perceived positively and is considered to be a form of life insurance, whereas the discharges are a limiting factor. The recipient's outlook on life changes. Acceptance of the changes resulting from the implant leads to the development of strategies to facilitate everyday life. An understanding of the significance attached by recipients to their disease, diagnosis and treatment allows their behaviour and expectations to be understood. Provide the basis for nursing assessment after discharge, understand the effects of the device in the recipient and track the process of adapting the recipient to daily life. © 2011 Blackwell Publishing Ltd.

  16. Electrostriction Effects During Defibrillation

    CERN Document Server

    Fritz, Michelle M; Roth, Bradley J

    2011-01-01

    Background-The electric field applied to the heart during defibrillation causes mechanical forces (electrostriction), and as a result the heart deforms. This paper analyses the physical origin of the deformation, and how significant it is. Methods-We represent the heart as an anisotropic cylinder. This simple geometry allows us to obtain analytical solutions for the potential, current density, charge, stress, and strain. Results-Charge induced on the heart surface in the presence of the electric field results in forces that deform the heart. In addition, the anisotropy of cardiac tissue creates a charge density throughout the tissue volume, leading to body forces. These two forces cause the tissue to deform in a complicated manner, with the anisotropy suppressing radial displacements in favor of tangential ones. Quantitatively, the deformation of the tissue is small, although it may be significant when using some imaging techniques that require the measurement of small displacements. Conclusions-The anisotrop...

  17. Integration of Attributes from Non-Linear Characterization of Cardiovascular Time-Series for Prediction of Defibrillation Outcomes.

    Directory of Open Access Journals (Sweden)

    Sharad Shandilya

    Full Text Available The timing of defibrillation is mostly at arbitrary intervals during cardio-pulmonary resuscitation (CPR, rather than during intervals when the out-of-hospital cardiac arrest (OOH-CA patient is physiologically primed for successful countershock. Interruptions to CPR may negatively impact defibrillation success. Multiple defibrillations can be associated with decreased post-resuscitation myocardial function. We hypothesize that a more complete picture of the cardiovascular system can be gained through non-linear dynamics and integration of multiple physiologic measures from biomedical signals.Retrospective analysis of 153 anonymized OOH-CA patients who received at least one defibrillation for ventricular fibrillation (VF was undertaken. A machine learning model, termed Multiple Domain Integrative (MDI model, was developed to predict defibrillation success. We explore the rationale for non-linear dynamics and statistically validate heuristics involved in feature extraction for model development. Performance of MDI is then compared to the amplitude spectrum area (AMSA technique.358 defibrillations were evaluated (218 unsuccessful and 140 successful. Non-linear properties (Lyapunov exponent > 0 of the ECG signals indicate a chaotic nature and validate the use of novel non-linear dynamic methods for feature extraction. Classification using MDI yielded ROC-AUC of 83.2% and accuracy of 78.8%, for the model built with ECG data only. Utilizing 10-fold cross-validation, at 80% specificity level, MDI (74% sensitivity outperformed AMSA (53.6% sensitivity. At 90% specificity level, MDI had 68.4% sensitivity while AMSA had 43.3% sensitivity. Integrating available end-tidal carbon dioxide features into MDI, for the available 48 defibrillations, boosted ROC-AUC to 93.8% and accuracy to 83.3% at 80% sensitivity.At clinically relevant sensitivity thresholds, the MDI provides improved performance as compared to AMSA, yielding fewer unsuccessful defibrillations

  18. Cross-validating a bidimensional mathematics anxiety scale.

    Science.gov (United States)

    Haiyan Bai

    2011-03-01

    The psychometric properties of a 14-item bidimensional Mathematics Anxiety Scale-Revised (MAS-R) were empirically cross-validated with two independent samples consisting of 647 secondary school students. An exploratory factor analysis on the scale yielded strong construct validity with a clear two-factor structure. The results from a confirmatory factor analysis indicated an excellent model-fit (χ(2) = 98.32, df = 62; normed fit index = .92, comparative fit index = .97; root mean square error of approximation = .04). The internal consistency (.85), test-retest reliability (.71), interfactor correlation (.26, p anxiety. Math anxiety, as measured by MAS-R, correlated negatively with student achievement scores (r = -.38), suggesting that MAS-R may be a useful tool for classroom teachers and other educational personnel tasked with identifying students at risk of reduced math achievement because of anxiety.

  19. LASSO with cross-validation for genomic selection.

    Science.gov (United States)

    Usai, M Graziano; Goddard, Mike E; Hayes, Ben J

    2009-12-01

    We used a least absolute shrinkage and selection operator (LASSO) approach to estimate marker effects for genomic selection. The least angle regression (LARS) algorithm and cross-validation were used to define the best subset of markers to include in the model. The LASSO-LARS approach was tested on two data sets: a simulated data set with 5865 individuals and 6000 Single Nucleotide Polymorphisms (SNPs); and a mouse data set with 1885 individuals genotyped for 10 656 SNPs and phenotyped for a number of quantitative traits. In the simulated data, three approaches were used to split the reference population into training and validation subsets for cross-validation: random splitting across the whole population; random sampling of validation set from the last generation only, either within or across families. The highest accuracy was obtained by random splitting across the whole population. The accuracy of genomic estimated breeding values (GEBVs) in the candidate population obtained by LASSO-LARS was 0.89 with 156 explanatory SNPs. This value was higher than those obtained by Best Linear Unbiased Prediction (BLUP) and a Bayesian method (BayesA), which were 0.75 and 0.84, respectively. In the mouse data, 1600 individuals were randomly allocated to the reference population. The GEBVs for the remaining 285 individuals estimated by LASSO-LARS were more accurate than those obtained by BLUP and BayesA for weight at six weeks and slightly lower for growth rate and body length. It was concluded that LASSO-LARS approach is a good alternative method to estimate marker effects for genomic selection, particularly when the cost of genotyping can be reduced by using a limited subset of markers.

  20. Frequent Home Monitoring of ICD Is Effective to Prevent Inappropriate Defibrillator Shock Delivery

    Directory of Open Access Journals (Sweden)

    Paolo Bifulco

    2014-01-01

    Full Text Available Recently, in the context of telemedicine, telemonitoring services are gaining attention. They are offered, for example, to patients with implantable cardioverter defibrillators (ICDs. A major problem associated with ICD therapy is the occurrence of inappropriate shocks which impair patients’ quality of life and may also be arrhythmogenic. The telemonitoring can provide a valid support to intensify followup visits, in order to improve the prevention of inappropriate defibrillator shock, thus enhancing patient safety. Inappropriate shock generally depends on atrial fibrillation, supraventricular tachycardia, and abnormal sensing (such as those caused by electromagnetic interferences. As a practical example, an unusual case of an ICD patient who risked an inappropriate shock while taking a shower is reported. Continuous remote telemonitoring was able to timely warn cardiologist via GSM-SMS, who were able to detect improper sensing examining the intracardiac electrogram via Web. Patient was promptly contacted and warned to not further come in contact with the hydraulic system and any electrical appliance to prevent an inappropriate defibrillator shock. This demonstrates the effectiveness and usefulness of continuous remote telemonitoring in supporting ICD patients.

  1. The Entirely Subcutaneous Defibrillator – A New Generation and Future Expectations

    Science.gov (United States)

    Ali, Hussam; Lupo, Pierpaolo; Cappato, Riccardo

    2015-01-01

    Although conventional implantable cardioverter-defibrillators (ICDs) have proved effective in the prevention of sudden cardiac death (SCD), they still appear to be limited by non-trivial acute and long-term complications. The recent advent of an entirely subcutaneous ICD (S-ICD) represents a further step in the evolution of defibrillation technology towards a less-invasive approach. This review highlights some historical and current issues concerning the S-ICD that may offer a viable therapeutic option in selected patients at high risk of SCD and in whom pacing is not required. After the CE Mark and US Food and Drug Administration (FDA) approvals, the S-ICD is being implanted worldwide with growing clinical data regarding its safety and efficacy (the EFFORTLESS Registry). The recently developed new generation of S-ICD (EMBLEM, Boston Scientific) demonstrates favourable features including a smaller device, longer longevity and remote-monitoring compatibility. Further innovations in the S-ICD system and potential integration with leadless pacing may play an important role in defibrillation therapy and prevention of SCD in the near future. PMID:26835112

  2. [Electrical storm in patients with prophylactic defibrillator implantation].

    Science.gov (United States)

    Rodríguez-Mañero, Moisés; González-Cambeiro, Cristina; Moreno-Arribas, Jose; Expósito-García, Víctor; Sánchez-Gómez, Juan Miguel; González-Torres, Luis; Arce-León, Álvaro; Arguedas-Jiménez, Hugo; Gaztañaga, Larraitz; Salvador-Montañés, Oscar; Iglesias-Bravo, Jose Antonio; Huerta, Ana Andrés La; Fernández-Armenta, Juan; Arias, Miguel Ángel; Martínez-Sande, Luis

    2016-01-01

    Little is known about the prevalence of electrical storm, baseline characteristics and mortality implications of patients with implantable cardioverter defibrillator in primary prevention versus those patients without electrical storm. We sought to assess the prevalence, baseline risk profile and survival significance of electrical storm in patients with implantable defibrillator for primary prevention. Retrospective multicenter study performed in 15 Spanish hospitals. Consecutives patients referred for desfibrillator implantation, with or without left ventricular lead (at least those performed in 2010 and 2011), were included. Over all 1,174 patients, 34 (2,9%) presented an electrical storm, mainly due to ventricular tachycardia (82.4%). There were no significant baseline differences between groups, with similar punctuation in the mortality risk scores (SHOCKED, MADIT and FADES). A clear trigger was identified in 47% of the events. During the study period (38±21 months), long-term total mortality (58.8% versus 14.4%, p<0.001) and cardiac mortality (52.9% versus 8.6%, p<0.001) were both increased among electrical storm patients. Rate of inappropriate desfibrillator intervention was also higher (14.7 versus 8.6%, p<0.001). In the present study of patients with desfibrillator implantation for primary prevention, prevalence of electrical storm was 2.9%. There were no baseline differences in the cardiovascular risk profile versus those without electrical storm. However, all cause mortality and cardiovascular mortality was increased in these patients versus control desfibrillator patients without electrical storm, as was the rate of inappropriate desfibrillator intervention. Copyright © 2015 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  3. Reuse of pacemakers, defibrillators and cardiac resynchronisation devices

    Science.gov (United States)

    Sakthivel, R; Satheesh, Santhosh; Ananthakrishna Pillai, Ajith; Sagnol, Pascal; Jouven, Xavier; Dodinot, Bernard; Balachander, Jayaraman

    2017-01-01

    Objective Access to pacemakers remains poor among many patients in low/middle-income countries. Reuse of explanted pacemakers is a possible solution, but is still not widespread because of concerns regarding outcomes, especially infection. Our objective was to study early outcomes with implants using reused devices and compare them with those with implants using new devices. Methods We studied all patients who underwent implantation of a new or reused pacemaker, cardiac resynchronisation therapy (CRT) device or implantable cardioverter defibrillator (ICD) in the last 5 years at a single institution. We analysed outcomes related to infection, device malfunction and device-related death within 6 months after initial implantation. Results During the study period, 887 patients underwent device implant, including 127 CRT devices or ICDs. Of these, 260 devices (29.3%) were reused and the others were new. At 6 months, there were three device-related infections in implants using a new device. There were no infections among patients receiving a reused device. There were no device malfunctions or device-related deaths in either group. Conclusions We found no difference in rate of infection or device malfunction among patients getting a reused device as compared with those with a new device. This study reinforces the safety of reusing devices for implant including CRT and ICDs. PMID:28176981

  4. Use of Automated External Defibrillators

    Energy Technology Data Exchange (ETDEWEB)

    Gregory K Christensen

    2009-02-01

    In an effort to improve survival from cardiac arrest, the American Heart Association (AHA) has promoted the Chain of Survival concept, describing a sequence of prehospital steps that result in improved survival after sudden cardiac arrest. These interventions include immediate deployment of emergency medical services, prompt cardiopulmonary resuscitation, early defibrillation when indicated, and early initiation of advanced medical care. Early defibrillation has emerged as the most important intervention with survival decreasing by 10% with each minute of delay in defibrillation. Ventricular Fibrillation (VF) is a condition in which there is uncoordinated contraction of the heart cardiac muscle of the ventricles in the heart, making them tremble rather than contract properly. VF is a medical emergency and if the arrhythmia continues for more than a few seconds, blood circulation will cease, and death can occur in a matter of minutes. During VF, contractions of the heart are not synchronized, blood flow ceases, organs begin to fail from oxygen deprivation and within 10 minutes, death will occur. When VF occurs, the victim must be defibrillated in order to establish the heart’s normal rhythm. On average, the wait for an ambulance in populated areas of the United States is about 11 minutes. In view of these facts, the EFCOG Electrical Safety Task Group initiated this review to evaluate the potential value of deployment and use of automated external defibrillators (AEDs) for treatment of SCA victims. This evaluation indicates the long term survival benefit to victims of SCA is high if treated with CPR plus defibrillation within the first 3-5 minutes after collapse. According to the American Heart Association (AHA), survival rates as high as 74% are possible if treatment and defibrillation is performed in the first 3 minutes. In contrast survival rates are only 5% where no AED programs have been established to provide prompt CPR and defibrillation. ["CPR statistics

  5. A Clinical Review of Implantable Cardioverter Defibrillators and Bi-Ventricular Pacemakers at one Institute

    Directory of Open Access Journals (Sweden)

    Ahmad Nasir

    2010-01-01

    Full Text Available Background: ICD/BVP indications are expanding. They areexpensive devices and historically, morbidities associated withtheir use were high. The starting experience at the Gold CoastHospital is being reviewed.Methods: A retrospective chart review of all the ICD/BVPsimplanted in the Gold Coast Hospital from 06/07/2007 –17/06/2008, with special emphasis on device indications andcomplications.Results: Devices implanted were (31. Primary preventiondevices (67%, secondary prevention devices (33%.Indications were; Non-ischemic Dilated Cardiomyopathy(35%, Out-of-hospital Cardiac Arrest (26%, Conscious VT(13%, Ischemic Dilated Cardiomyopathy (10%, In-hospitalCardiac Arrest (6%, Long-QT Syndrome (6% andCatecholamine-related Polymorphic VT (3%. Majorcomplications reported; lung contusion (1, left haemothorax(1, failed coronary sinus lead positioning (2, lead repositioning(2, atrial lead removal (1, left subclavian veinthrombosis (1, lead malfunction leading to VT under sensingand syncope (1. Device-administered therapies were eight;Inappropriate discharges (5, Appropriate discharges (1,successful Anti-tachycardia Pacing (2.Conclusions: We believe that ICDs are very effective lifesavingdevices but unfortunately they still are very expensiveand their use can be associated with significant morbiditiesespecially during the learning curve.

  6. Patients' perspective on deactivation of the implantable cardioverter-defibrillator near the end of life

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Chaitsing, Rismy; Szili-Torok, Tamas

    2013-01-01

    (67%) completed the survey. Most patients (68%) were aware that it is possible to turn the ICD off, and 95% believed it is important to inform patients about the possibility. Of the patients completing the survey, 84% indicated a choice for or against deactivation. Psychological morbidity...... was not associated with a response in favor or against deactivation (p >0.05 for all). The wish for a worthy death near the end of life was an independent associate of a favorable attitude toward deactivation (odds ratio 2.14, 95% confidence interval 1.49 to 3.06, p...

  7. Shock as a determinant of poor patient-centered outcomes in implantable cardioverter defibrillator patients

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Van Den Broek, Krista C; Van Den Berg, Martha

    2010-01-01

    as an outcome, and compare the influence of ICD shock with other factors (e.g., heart failure and psychological factors) as determinants of outcomes, with a view to providing recommendations for clinical practice and future research. Based on the large-scale primary and secondary prevention trials (i.e., CABG......-PATCH, CIDS, AVID, AMIOVIRT, SCD-HeFT, MADIT-II, and DEFINITE), evidence for an association between ICD shocks and quality of life is mixed, with some indication that the influence of shocks may depend largely on the interval between shocks and assessment of quality of life. In order to improve the clinical...... management of ICD patients, we need to adopt a more rigorous and standardized methodology in future studies in order to be able to draw firm conclusions about the impact of ICD shocks on individual patients. We also need to acknowledge that the impact of shocks on psychological functioning and quality...

  8. 77 FR 20873 - Qualification of Drivers; Application for Exemptions; Implantable Cardioverter Defibrillators

    Science.gov (United States)

    2012-04-06

    ... person has no current clinical diagnosis of myocardial infarction, angina pectoris, coronary... criteria indicate that: The term ``has no current clinical diagnosis of'' (1) a current cardiovascular.... The term ``known to be accompanied by'' is designed to include a clinical diagnosis of...

  9. Psychological vulnerability, ventricular tachyarrhythmias and mortality in implantable cardioverter defibrillator patients

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Brouwers, Corline; Versteeg, Henneke

    2012-01-01

    factors have not been considered as potential risk markers that might enhance the prediction of sudden cardiac death. This article evaluates the evidence for a link between psychological vulnerability, ventricular tachyarrhythmias and mortality and the pathways that might explain such a link. This review......, but information on the psychological profile of the patient may help to optimize the management and care of these patients in clinical practice....

  10. Ventricular Tachyarrhythmias and Mortality in Patients With an Implantable Cardioverter Defibrillator

    DEFF Research Database (Denmark)

    Mastenbroek, Mirjam H; Versteeg, Henneke; Jordaens, Luc

    2014-01-01

    .1] years) completed the Hospital Anxiety and Depression Scale 1 day before implantation. During follow-up, the ICD was interrogated at 3-month intervals. Cox proportional hazard regression analyses were used to examine the impact of depression on time to first appropriate ICD therapy and all-cause...... with an increased risk for all-cause mortality (unadjusted HR = 2.18, 95% CI = 1.36-3.49). Depression remained independently associated with all-cause mortality (HR = 1.94, 95% CI = 1.06-3.54, p = .031), after adjusting for demographic and clinical characteristics. Patients who remained depressed during the first 3...... months after implantation were at greatest risk for dying (HR = 2.88, 95% CI = 1.29-6.45, p = .010). Conclusions The current study showed that depression at the time of implant is not associated with time to first appropriate ICD therapy but almost doubled the risk for all-cause mortality in patients...

  11. My Child Needs or Has an Implantable Cardioverter-Defibrillator: What Should I Do?

    Science.gov (United States)

    ... Search Donate Circulation My alerts Sign In Join Facebook Twitter Home About this Journal Editorial Board General Statistics Circulation Doodle → Blip the Doodle Information for Advertisers Author Reprints Commercial Reprints Customer Service and Ordering ...

  12. Intensity of primary emotions in patients after implantation of an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Stoier, Louise; Pedersen, Preben Ulrich; Berg, Selina Kikkenborg

    2013-01-01

    -November 2009. A total number of 154 patients were needed in the trial. The data collected were compared with secondary data from patients who had recently suffered a Myocardial Infarction and from a healthy population. SPSS version 18.0 was used to analyze the data using t-test, chisquare and F...

  13. Possible Triggers and Temporal Patterns of Implantable Cardioverter Defibrillator Discharges: A Preliminary Study

    Science.gov (United States)

    1999-01-20

    there was a direct relationship between self-reported distress levels and occurrence of ectopic beats. These researchers later reported a negative...Furious (almost out of control. very angry, pounding table. slamming door) Very Angry (body tense, clenching fists or teeth ) Moderately angry (so...pounding table, slamming door) Very ADgry (body tense, clenching fists or teeth ) Moderately angry (so hassled it shows in your voice) Mlklly aDgry

  14. Clinical and psychological impact of prophylactic implantable cardioverter-defibrillators in a community heart failure population.

    LENUS (Irish Health Repository)

    Arnous, S

    2012-02-01

    AIMS: ICD implantation for primary prevention of sudden cardiac death in patients with left ventricular systolic dysfunction (ejection fraction <\\/= 35%) has increased since the publication of the SCD-HEFT and MADIT-II data. The aim of this study is to examine the effectiveness and safety of prophylactic ICD use in a community heart failure population and to assess the impact on patient\\'s quality of life. METHODS AND RESULTS: Seventy-one ICDs were inserted between the years 2002 and 2006. The mean follow-up from time of insertion was 24 +\\/- 11 months. Eighteen patients (25%) had potentially life-saving therapy. Seven (10%) patients received inappropriate shocks. Complications were encountered in five patients (7%). CONCLUSION: In a community heart failure population, prophylactic ICD implantation is associated with a high incidence of life-saving therapy, a low complication rate and a high level of tolerability. These data indicate translation of clinical trial benefits to the general heart failure population.

  15. Dental management of a patient fitted with subcutaneous Implantable Cardioverter Defibrillator device and concomitant warfarin treatment

    Directory of Open Access Journals (Sweden)

    Altaf Hussain Shah

    2015-07-01

    This article presents the dental management of a 60 year-old person with an ICD and concomitant anticoagulant therapy. The patient was on multiple medications and was treated for a grossly neglected mouth with multiple carious root stumps. This case report outlines the important issues in managing patients fitted with an ICD device and at a risk of sudden cardiac death.

  16. The gulf implantable cardioverter-defibrillator registry: Rationale, methodology, and implementation

    Directory of Open Access Journals (Sweden)

    Alawi A Alsheikh-Ali

    2015-01-01

    Conclusions: Gulf ICD is the first prospective, observational, multi-center, and multinational study of the characteristics and, the outcomes of patients receiving ICDs in the Arab Gulf region. The study will provide valuable insights into the utilization of and outcomes related to ICD therapy in the Gulf region.

  17. Circadian variations in the occurrence of ventricular tachyarrhythmias in patients with implantable cardioverter defibrillators.

    Science.gov (United States)

    Kozák, Milan; Krivan, Lubomír; Semrád, Borivoj

    2003-03-01

    A circadian distribution has been demonstrated in episodes of sudden cardiac death, acute myocardial infarction, ventricular premature complexes, heart rate variability, and ventricular tachyarrhythmias. The aim of this study was to evaluate the circadian distribution of ventricular tachyarrhythmia episodes in a population of ICD patients. Data were gathered from 72 patients (55 men, 17 women; mean age 62.7 +/- 12.2 years, mean LVEF 0.0037 +/- 0.0011) with ICDs implanted for standard indications. Patients were followed every 3 months over a mean period of 21 +/- 12.8 months. At each examination, symptoms at arrhythmia onset and perception of ICD therapy were recorded, and the ICD memory was interrogated. During follow-up, 1,023 episodes' of malignant ventricular arrhythmias were detected and effectively terminated, 506 of which were fully analyzed. A morning peak in ventricular tachyarrhythmias was demonstrated between 7:00 and 11:00 AM, and an afternoon peak between 6:00 and 7:00 PM. A significantly lower occurrence of VT was observed at 1:00 AM and between 4:00 and 6:00 AM. A circadian distribution in the occurrence of ventricular tachycardias was found. The three striking features of the data are: the early morning peak (about three hours after waking up), relatively stable incidence throughout waking hours, and decline in incidence in the previous period.

  18. Temporal complexity of repolarization and mortality in patients with implantable cardioverter defibrillators.

    Science.gov (United States)

    Perkiomaki, Juha S; Couderc, Jean-Philippe; Daubert, James P; Zareba, Wojciech

    2003-10-01

    Increased repolarization variability has been observed in various cardiac conditions. However, data on its relation to heart rate variability and on its value in predicting adverse outcomes in high risk patients are limited. Forty-seven patients with decreased left ventricular function and ICDs had high resolution 10-minute ECG recordings and were followed for 781 +/- 258 days (mean +/- SD) on average. The interval from the R peak to the T wave peak with maximum amplitude (RTmax) and from the R peak to the T wave offset (RToff) were determined automatically on a beat-to-beat basis. Temporal beat-to-beat RTmax and RToff variability were analyzed using traditional summary statistics, a complexity measure (approximate entropy [ApEn]), and the short-term scaling exponent (alpha1). Eight (17%) patients died and 16 (34%) patients experienced death/appropriate ICD shock during follow-up. RTmax-ApEn was significantly higher in patients who died compared with patients who survived (1.24 +/- 0.13 vs 1.01 +/- 0.21, respectively, P=0.008). When RTmax-ApEn was tested together with the alpha1 of the RR intervals, occurrence of ventricular arrhythmias before ICD implantation, and beta-blockers usage in the Cox regression analysis, it still independently predicted mortality; hazard ratio=3.36 (1.28-8.83, 95% CI, P=0.014) for every 0.10-increase in RTmax-ApEn. None of the repolarization variability parameters independently predicted death/appropriate ICD shocks. Increased temporal complexity of repolarization (RTmax-ApEn) independently predicts mortality in ICD patients.

  19. Poor perceived social support in implantable cardioverter defibrillator (ICD) patients and their partners

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Spinder, Helle; Erdman, Ruud A M;

    2009-01-01

    Social support is a known buffer of psychological distress and has also been shown to influence adverse medical outcomes.......Social support is a known buffer of psychological distress and has also been shown to influence adverse medical outcomes....

  20. Long-term survival of implantable cardioverter defibrillator recipients with end-stage renal disease

    Directory of Open Access Journals (Sweden)

    Mikhael F. El-Chami, MD, FACC, FHRS

    2017-10-01

    Conclusion: ESRD patients are at significantly increased risk of mortality as compared with a non-dialysis cohort. While the majority of these patients survive more than one year post-diagnosis, the three-year mortality is high (43%. Randomized studies addressing the benefits of ICDs in ESRD patients are needed to better define their value for primary prevention of SCD.

  1. Initial experience with the subcutaneous implantable cardioverter-defibrillator in a single Japanese center

    Directory of Open Access Journals (Sweden)

    Nobuhiro Nishii, MD

    2017-08-01

    Conclusions: S-ICD implantation appears to provide a viable alternative to transvenous ICD implantation for some Japanese patients. However, we should perform careful follow-up of patients to eliminate inappropriate therapy.

  2. Low disease prevalence and inappropriate implantable cardioverter defibrillator shock rate in Brugada syndrome

    DEFF Research Database (Denmark)

    Holst, Anders Gaarsdal; Jensen, Henrik Kjærulf; Eschen, Ole

    2012-01-01

    Brugada syndrome (BrS) is an inherited channelopathy that predisposes to malignant ventricular arrhythmias and thereby syncope and sudden cardiac death. Prior studies characterizing BrS patients have used highly selected referral populations from tertiary centres and prevalence estimates have been...

  3. Automated external cardioversion defibrillation monitoring in cardiac arrest: a randomized trial

    Directory of Open Access Journals (Sweden)

    Norvel Robert

    2008-06-01

    Full Text Available Abstract Background In-hospital cardiac arrest has a poor prognosis despite active electrocardiography monitoring. The initial rhythm of approximately 25% of in-hospital cardiopulmonary resuscitation (CPR events is pulseless ventricular tachycardia/ventricular fibrillation (VT/VF. Early defibrillation is an independent predictor of survival in CPR events caused by VT/VF. The automated external cardioverter defibrillator (AECD is a device attached by pads to the chest wall that monitors, detects, and within seconds, automatically delivers electric countershock to an appropriate tachyarrhythmia. Study Objectives • To evaluate safety of AECD monitoring in hospitalized patients. • To evaluate whether AECDs provide earlier defibrillation than hospital code teams. Methods The study is a prospective trial randomizing patients admitted to the telemetry ward to standard CPR (code team or standard CPR plus AECD monitoring (PowerHeart CRM. The AECD is programmed to deliver one 150 J biphasic shock to patients in sustained VT/VF. Data is collected using the Utstein criteria for cardiac arrest. The primary endpoint is time-to-defibrillation; secondary outcomes include neurological status and survival to discharge, with 3-year follow-up. Results To date, 192 patients have been recruited in the time period between 10/10/2006 to 7/20/2007. A total of 3,655 hours of telemetry data have been analyzed in the AECD arm. The AECD has monitored ambulatory telemetry patients in sinus rhythm, sinus tachycardia, supraventricular tachycardia, atrial flutter or fibrillation, with premature ventricular complexes and non-sustained VT without delivery of inappropriate shocks. One patient experienced sustained VT during AECD monitoring, who was successfully defibrillated (17 seconds after meeting programmed criteria. There are no events to report in the control arm. The patient survived the event without neurological complications. During the same time period, mean time to

  4. A second defibrillator chest patch electrode will increase implantation rates for nonthoracotomy defibrillators.

    Science.gov (United States)

    Solomon, A J; Swartz, J F; Rodak, D J; Moore, H J; Hannan, R L; Tracy, C M; Fletcher, R D

    1996-09-01

    Nonthoracotomy defibrillator systems can be implanted with a lower morbidity and mortality, compared to epicardial systems. However, implantation may be unsuccessful in up to 15% of patients, using a monophasic waveform. It was the purpose of this study to prospectively examine the efficacy of a second chest patch electrode in a nonthoracotomy defibrillator system. Fourteen patients (mean age 62 +/- 11 years, ejection fraction = 0.29 +/- 0.12) with elevated defibrillation thresholds, defined as > or = 24 J, were studied. The initial lead system consisted of a right ventricular electrode (cathode), a left innominate vein, and subscapular chest patch electrode (anodes). If the initial defibrillation threshold was > or = 24 J, a second chest patch electrode was added. This was placed subcutaneously in the anterior chest (8 cases), or submuscularly in the subscapular space (6 cases). This resulted in a decrease in the system impedance at the defibrillation threshold, from 72.3 +/- 13.3 omega to 52.2 +/- 8.6 omega. Additionally, the defibrillation threshold decreased from > or = 24 J, with a single patch, to 16.6 +/- 2.8 J with two patches. These changes were associated with successful implantation of a nonthoracotomy defibrillator system in all cases. In conclusion, the addition of a second chest patch electrode (using a subscapular approach) will result in lower defibrillation thresholds in patients with high defibrillation thresholds, and will subsequently increase implantation rates for nonthoracotomy defibrillators.

  5. Electrical Heart Defibrillation with Ion Channel Blockers

    Science.gov (United States)

    Feeney, Erin; Clark, Courtney; Puwal, Steffan

    Heart disease is the leading cause of mortality in the United States. Rotary electrical waves within heart muscle underlie electrical disorders of the heart termed fibrillation; their propagation and breakup leads to a complex distribution of electrical activation of the tissue (and of the ensuing mechanical contraction that comes from electrical activation). Successful heart defibrillation has, thus far, been limited to delivering large electrical shocks to activate the entire heart and reset its electrical activity. In theory, defibrillation of a system this nonlinear should be possible with small electrical perturbations (stimulations). A successful algorithm for such a low-energy defibrillator continues to elude researchers. We propose to examine in silica whether low-energy electrical stimulations can be combined with antiarrhythmic, ion channel-blocking drugs to achieve a higher rate of defibrillation and whether the antiarrhythmic drugs should be delivered before or after electrical stimulation has commenced. Progress toward a more successful, low-energy defibrillator will greatly minimize the adverse effects noted in defibrillation and will assist in the development of pediatric defibrillators.

  6. Study of Cardiac Defibrillation Through Numerical Simulations

    Science.gov (United States)

    Bragard, J.; Marin, S.; Cherry, E. M.; Fenton, F. H.

    Three-dimensional numerical simulations of the defibrillation problem are presented. In particular, in this study we use the rabbit ventricular geometry as a realistic model system for evaluating the efficacy of defibrillatory shocks. Statistical data obtained from the simulations were analyzed in term of a dose-response curve. Good quantitative agreement between our numerical results and clinically relevant values is obtained. An electric field strength of about 6.6 V/cm indicates a fifty percent probability of successful defibrillation for a 12-ms monophasic shock. Our validated model will be useful for optimizing defibrillation protocols.

  7. Implantable defibrillator lead extraction with optimized standard extraction techniques

    Institute of Scientific and Technical Information of China (English)

    Xian-Ming Chu; Xue-Bin Li; Ping Zhang; Yi An; Jiang-Bo Duan; Long Wang; Ding Li; Bing Li; Ji-Hong Guo

    2013-01-01

    Background Implantable cardioverter-defibrillator (ICD) leads might not be extracted especially in developing countries because of the high cost and lack of specialized tools. We aimed to evaluate transvenous extraction of ICD leads using optimized standard techniques. Methods We prospectively analyzed clinical characteristics, optimized extraction techniques and the feasibility of extraction for 40 patients (33 males; mean age 47.9 ± 16.1 years) with 42 ICD leads. Results Complete procedural success rate was 95.2% (40/42), and the clinical success rate was 97.6% (41/42). One ICD lead required cardiothoracic surgery. Minor complications occurred in three cases (7.5%), and no major complications or death occurred. Locking stylets were used to extract most leads (34, 81.0%) and almost half of the leads (20, 47.6%) required mechanical dilatation to free fibrotic adhesions; these leads had been implanted for a longer period of time than the others (43.7 ± 18.2 vs. 18.4 ± 13.4 months, P < 0.05). Three-quarters of the leads (30, 71.4%) were extracted with locking stylets plus manual traction (12, 28.6%), or mechanical dilatation with counter-traction (18, 42.8%) by the superior vena cava approach and one-quarter of the leads (11, per lead. Linear regression analysis showed that the extraction time was significantly correlated with implant duration (r = 0.70, P < 0.001). optimized procedure for transvenous extraction of ICD leads provides a practical and low-cost method for standard procedures.

  8. Biased binomial assessment of cross-validated estimation of classification accuracies illustrated in diagnosis predictions

    Directory of Open Access Journals (Sweden)

    Quentin Noirhomme

    2014-01-01

    Full Text Available Multivariate classification is used in neuroimaging studies to infer brain activation or in medical applications to infer diagnosis. Their results are often assessed through either a binomial or a permutation test. Here, we simulated classification results of generated random data to assess the influence of the cross-validation scheme on the significance of results. Distributions built from classification of random data with cross-validation did not follow the binomial distribution. The binomial test is therefore not adapted. On the contrary, the permutation test was unaffected by the cross-validation scheme. The influence of the cross-validation was further illustrated on real-data from a brain–computer interface experiment in patients with disorders of consciousness and from an fMRI study on patients with Parkinson disease. Three out of 16 patients with disorders of consciousness had significant accuracy on binomial testing, but only one showed significant accuracy using permutation testing. In the fMRI experiment, the mental imagery of gait could discriminate significantly between idiopathic Parkinson's disease patients and healthy subjects according to the permutation test but not according to the binomial test. Hence, binomial testing could lead to biased estimation of significance and false positive or negative results. In our view, permutation testing is thus recommended for clinical application of classification with cross-validation.

  9. Biased binomial assessment of cross-validated estimation of classification accuracies illustrated in diagnosis predictions.

    Science.gov (United States)

    Noirhomme, Quentin; Lesenfants, Damien; Gomez, Francisco; Soddu, Andrea; Schrouff, Jessica; Garraux, Gaëtan; Luxen, André; Phillips, Christophe; Laureys, Steven

    2014-01-01

    Multivariate classification is used in neuroimaging studies to infer brain activation or in medical applications to infer diagnosis. Their results are often assessed through either a binomial or a permutation test. Here, we simulated classification results of generated random data to assess the influence of the cross-validation scheme on the significance of results. Distributions built from classification of random data with cross-validation did not follow the binomial distribution. The binomial test is therefore not adapted. On the contrary, the permutation test was unaffected by the cross-validation scheme. The influence of the cross-validation was further illustrated on real-data from a brain-computer interface experiment in patients with disorders of consciousness and from an fMRI study on patients with Parkinson disease. Three out of 16 patients with disorders of consciousness had significant accuracy on binomial testing, but only one showed significant accuracy using permutation testing. In the fMRI experiment, the mental imagery of gait could discriminate significantly between idiopathic Parkinson's disease patients and healthy subjects according to the permutation test but not according to the binomial test. Hence, binomial testing could lead to biased estimation of significance and false positive or negative results. In our view, permutation testing is thus recommended for clinical application of classification with cross-validation.

  10. Outlier detection in near-infrared spectroscopic analysis by using Monte Carlo cross-validation

    Institute of Scientific and Technical Information of China (English)

    LIU ZhiChao; CAI WenSheng; SHAO XueGuang

    2008-01-01

    An outlier detection method is proposed for near-infrared spectral analysis. The underlying philosophy of the method is that, in random test (Monte Carlo) cross-validation, the probability of outliers pre-senting in good models with smaller prediction residual error sum of squares (PRESS) or in bad mod-els with larger PRESS should be obviously different from normal samples. The method builds a large number of PLS models by using random test cross-validation at first, then the models are sorted by the PRESS, and at last the outliers are recognized according to the accumulative probability of each sam-ple in the sorted models. For validation of the proposed method, four data sets, including three pub-lished data sets and a large data set of tobacco lamina, were investigated. The proposed method was proved to be highly efficient and veracious compared with the conventional leave-one-out (LOO) cross validation method.

  11. Cross-validation of component models: a critical look at current methods.

    Science.gov (United States)

    Bro, R; Kjeldahl, K; Smilde, A K; Kiers, H A L

    2008-03-01

    In regression, cross-validation is an effective and popular approach that is used to decide, for example, the number of underlying features, and to estimate the average prediction error. The basic principle of cross-validation is to leave out part of the data, build a model, and then predict the left-out samples. While such an approach can also be envisioned for component models such as principal component analysis (PCA), most current implementations do not comply with the essential requirement that the predictions should be independent of the entity being predicted. Further, these methods have not been properly reviewed in the literature. In this paper, we review the most commonly used generic PCA cross-validation schemes and assess how well they work in various scenarios.

  12. Outlier detection in near-infrared spectroscopic analysis by using Monte Carlo cross-validation

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    An outlier detection method is proposed for near-infrared spectral analysis. The underlying philosophy of the method is that,in random test(Monte Carlo) cross-validation,the probability of outliers presenting in good models with smaller prediction residual error sum of squares(PRESS) or in bad models with larger PRESS should be obviously different from normal samples. The method builds a large number of PLS models by using random test cross-validation at first,then the models are sorted by the PRESS,and at last the outliers are recognized according to the accumulative probability of each sample in the sorted models. For validation of the proposed method,four data sets,including three published data sets and a large data set of tobacco lamina,were investigated. The proposed method was proved to be highly efficient and veracious compared with the conventional leave-one-out(LOO) cross validation method.

  13. Non-linear dynamical signal characterization for prediction of defibrillation success through machine learning

    Directory of Open Access Journals (Sweden)

    Shandilya Sharad

    2012-10-01

    Full Text Available Abstract Background Ventricular Fibrillation (VF is a common presenting dysrhythmia in the setting of cardiac arrest whose main treatment is defibrillation through direct current countershock to achieve return of spontaneous circulation. However, often defibrillation is unsuccessful and may even lead to the transition of VF to more nefarious rhythms such as asystole or pulseless electrical activity. Multiple methods have been proposed for predicting defibrillation success based on examination of the VF waveform. To date, however, no analytical technique has been widely accepted. We developed a unique approach of computational VF waveform analysis, with and without addition of the signal of end-tidal carbon dioxide (PetCO2, using advanced machine learning algorithms. We compare these results with those obtained using the Amplitude Spectral Area (AMSA technique. Methods A total of 90 pre-countershock ECG signals were analyzed form an accessible preshosptial cardiac arrest database. A unified predictive model, based on signal processing and machine learning, was developed with time-series and dual-tree complex wavelet transform features. Upon selection of correlated variables, a parametrically optimized support vector machine (SVM model was trained for predicting outcomes on the test sets. Training and testing was performed with nested 10-fold cross validation and 6–10 features for each test fold. Results The integrative model performs real-time, short-term (7.8 second analysis of the Electrocardiogram (ECG. For a total of 90 signals, 34 successful and 56 unsuccessful defibrillations were classified with an average Accuracy and Receiver Operator Characteristic (ROC Area Under the Curve (AUC of 82.2% and 85%, respectively. Incorporation of the end-tidal carbon dioxide signal boosted Accuracy and ROC AUC to 83.3% and 93.8%, respectively, for a smaller dataset containing 48 signals. VF analysis using AMSA resulted in accuracy and ROC AUC of 64

  14. Ensemble Kalman filter regularization using leave-one-out data cross-validation

    KAUST Repository

    Rayo Schiappacasse, Lautaro Jerónimo

    2012-09-19

    In this work, the classical leave-one-out cross-validation method for selecting a regularization parameter for the Tikhonov problem is implemented within the EnKF framework. Following the original concept, the regularization parameter is selected such that it minimizes the predictive error. Some ideas about the implementation, suitability and conceptual interest of the method are discussed. Finally, what will be called the data cross-validation regularized EnKF (dCVr-EnKF) is implemented in a 2D 2-phase synthetic oil reservoir experiment and the results analyzed.

  15. Accelerating cross-validation with total variation and its application to super-resolution imaging

    CERN Document Server

    Obuchi, Tomoyuki; Akiyama, Kazunori; Kabashima, Yoshiyuki

    2016-01-01

    We develop an approximation formula for the cross-validation error (CVE) of a sparse linear regression penalized by $\\ell_1$-norm and total variation terms, which is based on a perturbative expansion utilizing the largeness of both the data dimensionality and the model. The developed formula allows us to reduce the necessary computational cost of the CVE evaluation significantly. The practicality of the formula is tested through application to simulated black-hole image reconstruction on the event-horizon scale with super resolution. The results demonstrate that our approximation reproduces the CVE values obtained via literally conducted cross-validation with reasonably good precision.

  16. A New Symptom Model for Autism Cross-Validated in an Independent Sample

    Science.gov (United States)

    Boomsma, A.; Van Lang, N. D. J.; De Jonge, M. V.; De Bildt, A. A.; Van Engeland, H.; Minderaa, R. B.

    2008-01-01

    Background: Results from several studies indicated that a symptom model other than the DSM triad might better describe symptom domains of autism. The present study focused on a) investigating the stability of a new symptom model for autism by cross-validating it in an independent sample and b) examining the invariance of the model regarding three…

  17. Cross-Validation of the Risk Matrix 2000 Sexual and Violent Scales

    Science.gov (United States)

    Craig, Leam A.; Beech, Anthony; Browne, Kevin D.

    2006-01-01

    The predictive accuracy of the newly developed actuarial risk measures Risk Matrix 2000 Sexual/Violence (RMS, RMV) were cross validated and compared with two risk assessment measures (SVR-20 and Static-99) in a sample of sexual (n = 85) and nonsex violent (n = 46) offenders. The sexual offense reconviction rate for the sex offender group was 18%…

  18. Cross-Validating Chinese Language Mental Health Recovery Measures in Hong Kong

    Science.gov (United States)

    Bola, John; Chan, Tiffany Hill Ching; Chen, Eric HY; Ng, Roger

    2016-01-01

    Objectives: Promoting recovery in mental health services is hampered by a shortage of reliable and valid measures, particularly in Hong Kong. We seek to cross validate two Chinese language measures of recovery and one of recovery-promoting environments. Method: A cross-sectional survey of people recovering from early episode psychosis (n = 121)…

  19. Cross-validation of the benzodiazepine dependence self-report questionnaire in outpatient benzodiazepine users.

    NARCIS (Netherlands)

    Kan, C.C.; Breteler, M.H.M.; Ven, A.H.G.S. van der; Zitman, F.G.

    2001-01-01

    The aim of this study was to cross-validate the Benzodiazepine Dependence Self-Report Questionnaire (Bendep-SRQ), which reflects the severity of benzodiazepine (BZD) dependence. The Bendep-SRQ, Symptom Checklist-90 (SCL-90) Schedules for Clinical Assessments in Neuropsychiatry (SCAN), and Addiction

  20. Cross-validation of the Benzodiazepine Dependence Self-Report Questionnaire in Outpatient Benzodiazepine Users

    NARCIS (Netherlands)

    Kan, C.C.; Breteler, M.H.M.; Ven, A.H.G.S. van der; Zitman, F.G.

    2001-01-01

    The aim of this study was to cross-validate the Benzodiazepine Dependence Self-Report Questionnaire (Bendep-SRQ), which reflects the severity of benzodiazepine (BZD) dependence. The Bendep-SRQ, Symptom Checklist-90 (SCL-90) Schedules for Clinical Assessments in Neuropsychiatry (SCAN), and Addiction

  1. Cross-Validating Chinese Language Mental Health Recovery Measures in Hong Kong

    Science.gov (United States)

    Bola, John; Chan, Tiffany Hill Ching; Chen, Eric HY; Ng, Roger

    2016-01-01

    Objectives: Promoting recovery in mental health services is hampered by a shortage of reliable and valid measures, particularly in Hong Kong. We seek to cross validate two Chinese language measures of recovery and one of recovery-promoting environments. Method: A cross-sectional survey of people recovering from early episode psychosis (n = 121)…

  2. Cross-Validation of a Short Form of the Marlowe-Crowne Social Desirability Scale.

    Science.gov (United States)

    Zook, Avery, II; Sipps, Gary J.

    1985-01-01

    Presents a cross-validation of Reynolds' short form of the Marlowe-Crowne Social Desirability Scale (N=233). Researchers administered 13 items as a separate entity, calculated Cronbach's Alpha for each sex, and computed test-retest correlation for one group. Concluded that the short form is a viable alternative. (Author/NRB)

  3. Defibrillation lead placement using a transthoracic transatrial approach in a case without transvenous access due to lack of the right superior vena cava.

    Science.gov (United States)

    Otsuka, Yosuke; Okamura, Hideo; Sato, Syunsuke; Nakajima, Ikutaro; Ishibashi, Kohei; Miyamoto, Kouji; Noda, Takashi; Aiba, Takeshi; Kamakura, Shiro; Kobayashi, Junjiro; Yasuda, Satoshi; Ogawa, Hisao; Kusano, Kengo

    2015-06-01

    A 65-year-old woman with a history of syncope was diagnosed with hypertrophic cardiomyopathy. She had previously undergone mastectomy of the left breast owing to breast cancer. Holter electrocardiogram (ECG) and monitor ECG revealed sick sinus syndrome (Type II) and non-sustained ventricular tachycardia. Sustained ventricular tachycardia and ventricular fibrillation were induced in an electrophysiological study. Although the patient was eligible for treatment with a dual chamber implantable cardioverter defibrillator (ICD), venography revealed lack of the right superior vena cava (R-SVC). Lead placement from the left subclavian vein would have increased the risk of lymphedema owing to the patient׳s mastectomy history. Consequently, the defibrillation lead was placed in the right ventricle by direct puncture of the right auricle through the tricuspid valve. The atrial lead was sutured to the atrial wall, and the postoperative course was unremarkable. Defibrillation lead placement using a transthoracic transatrial approach can be an alternative method in cases where a transvenous approach for lead placement is not feasible.

  4. Validation of defibrillator lead performance registry data

    DEFF Research Database (Denmark)

    Kristensen, Anders Elgaard; Larsen, Jacob Moesgaard; Nielsen, Jens Cosedis

    2016-01-01

    AIMS: The validity of registry data on defibrillator lead performance is described only sparsely, despite its clinical importance. This study investigated the validity of defibrillator lead performance registry data in a nationwide and population-based registry. METHODS AND RESULTS: We identified...... all reported surgical interventions due to defibrillator lead events in the Danish Pacemaker and ICD Register (DPIR) from 2000 to 2013. Medical records of all patients (n = 753) were examined blinded for 5 predefined intervention types and 18 reasons for lead intervention. The overall level...... of agreement for the types of lead intervention had a positive predictive value (PPV) of 89.4% [95% confidence interval (CI): 87.0-91.5%] and an adjusted agreement (κ value) of 0.81 (95% CI: 0.77-0.85) representing an almost perfect match. Regarding the reasons for lead intervention, the overall PPV was 63...

  5. [Research on automatic external defibrillator based on DSP].

    Science.gov (United States)

    Jing, Jun; Ding, Jingyan; Zhang, Wei; Hong, Wenxue

    2012-10-01

    Electrical defibrillation is the most effective way to treat the ventricular tachycardia (VT) and ventricular fibrillation (VF). An automatic external defibrillator based on DSP is introduced in this paper. The whole design consists of the signal collection module, the microprocessor controlingl module, the display module, the defibrillation module and the automatic recognition algorithm for VF and non VF, etc. This automatic external defibrillator has achieved goals such as ECG signal real-time acquisition, ECG wave synchronous display, data delivering to U disk and automatic defibrillate when shockable rhythm appears, etc.

  6. Canadian Registry of ICD Implant Testing procedures (CREDIT): current practice, risks, and costs of intraoperative defibrillation testing.

    Science.gov (United States)

    Healey, Jeff S; Dorian, Paul; Mitchell, L Brent; Talajic, Mario; Philippon, Francois; Simpson, Chris; Yee, Raymond; Morillo, Carlos A; Lamy, Andre; Basta, Magdy; Birnie, David H; Wang, Xiaoyin; Nair, Girish M; Crystal, Eugene; Kerr, Charles R; Connolly, Stuart J

    2010-02-01

    There is uncertainty about the proper role of defibrillation testing (DT) at the time of implantable cardioverter defibrillator (ICD) insertion. A prospective registry was conducted at 13 sites in Canada between January 2006 and October 2007. To document the details of DT, the reasons for not conducting DT, and the costs and complications associated with DT. DT was conducted at implantation in 230 of 361 patients (64%). DT was more likely to be conducted for new implants compared with impulse generator replacements (71% vs 32%, P = 0.0001), but was similar for primary and secondary prevention indications (64% vs 63%, P = NS). Among patients not having DT, the reason(s) given were: considered unnecessary (44%); considered unsafe, mainly due to persistent atrial fibrillation (37%); lack of an anesthetist (20%); and, patient or physician preference (6%). When performed, DT consisted of a single successful shock > or = 10J below maximum device output in 65% of cases. A 10J safety-margin was met by 97% of patients, requiring system modification in 2.3%. Major perioperative complications occurred in 4.4% of patients having DT versus 6.6% of patients not having DT (P = NS). ICD insertion was $844 more expensive for patients having DT (P = 0.16), largely due to increased costs ($28,017 vs $24,545) among patients having impulse generator replacement (P = 0.02). DT was not performed in a third of ICD implants, usually due to a perceived lack of need or relative contraindication.

  7. Imaging of Ventricular Fibrillation and Defibrillation: The Virtual Electrode Hypothesis.

    Science.gov (United States)

    Boukens, Bastiaan J; Gutbrod, Sarah R; Efimov, Igor R

    2015-01-01

    Ventricular fibrillation is the major underlying cause of sudden cardiac death. Understanding the complex activation patterns that give rise to ventricular fibrillation requires high resolution mapping of localized activation. The use of multi-electrode mapping unraveled re-entrant activation patterns that underlie ventricular fibrillation. However, optical mapping contributed critically to understanding the mechanism of defibrillation, where multi-electrode recordings could not measure activation patterns during and immediately after a shock. In addition, optical mapping visualizes the virtual electrodes that are generated during stimulation and defibrillation pulses, which contributed to the formulation of the virtual electrode hypothesis. The generation of virtual electrode induced phase singularities during defibrillation is arrhythmogenic and may lead to the induction of fibrillation subsequent to defibrillation. Defibrillating with low energy may circumvent this problem. Therefore, the current challenge is to use the knowledge provided by optical mapping to develop a low energy approach of defibrillation, which may lead to more successful defibrillation.

  8. Infarct size and recurrence of ventricular arrhythmias after defibrillator implantation

    Energy Technology Data Exchange (ETDEWEB)

    Sutter, J. de; Tavernier, R.; Kazmierckzak, J.; Buyzere, M. de; Clement, D.L. [Department of Cardiology, University Hospital Gent, Gent (Belgium); Wiele, C. van de; Dierckx, R.A. [Department of Nuclear Medicine, University Hospital Gent (Belgium); Jordaens, L. [Thoraxcenter, University Hospital Rotterdam-Dijkzigt (Netherlands)

    2000-07-01

    Infarct size as determined by perfusion imaging is an independent predictor of mortality after implantable cardioverter defibrillator (ICD) implantation in patients with coronary artery disease (CAD) and life-threatening ventricular arrhythmias (VA). However, its value as a predictor of VA recurrence and hospitalisation after ICD implantation is unknown. Therefore, the objective of this study was to evaluate whether infarct size as determined by perfusion imaging can help to identify patients who are at high risk for recurrence of VA and hospitalisation after ICD implantation. We studied 56 patients with CAD and life-threatening VA. Before ICD implantation, all patients underwent a uniform study protocol including a thallium-201 stress-redistribution perfusion study. A defect score as a measurement of infarct size was calculated using a 17-segment 5-point scoring system. Study endpoints during follow-up were documented episodes of appropriate anti-tachycardia pacing and/or shocks for VA and cardiac hospitalisation for electrical storm (defined as three or more appropriate ICD interventions within 24 h), heart failure or angina. After a mean follow-up of 470{+-}308 days, 22 patients (39%) had recurrences of VA. In univariate analysis, predictors for recurrence were: (a) ventricular tachycardia (VT) as the initial presenting arrhythmia (86% vs 59% for patients without ICD therapy, P=0.04), (b) treatment with {beta}-blockers (36% vs 68%, P=0.03) and (c) a defect score (DS) {>=}20 (64% vs 32%, P=0.03). In multivariate analysis, VT as the presenting arrhythmia ({chi}2=5.51, P=0.02) and a DS {>=}20 ({chi}2=4.22, P=0.04) remained independent predictors. Cardiac hospitalisation was more frequent in patients with a DS {>=}20 (44% vs 13% for patients with DS <20, P=0.015) and this was particularly due to more frequent hospitalisations for electrical storm (24% vs 3% for patients with DS<20, P=0.037). The extent of scarring determined by perfusion imaging can separate

  9. Technologic advances and program initiatives in public access defibrillation using automated external defibrillators.

    Science.gov (United States)

    White, R D

    2001-06-01

    Widespread provision of early defibrillation following cardiac arrest holds major promise for improved survival from ventricular fibrillation. The critical element in predicting a successful outcome is the rapidity with which defibrillation is achieved. A worldwide awareness of this potential and its advocacy by such organizations as the American Heart Association have been pivotal in the evolution of initiatives to make defibrillation more widely and more rapidly available. The feasibility of this initiative, known as public access defibrillation, is in large measure a direct consequence of major technologic advances in automated external defibrillators (AEDs). New low-energy waveforms with biphasic morphology have been shown to be more effective in terminating ventricular fibrillation and may do so with less myocardial injury. Placement of AEDs in a variety of nontraditional settings such as police cars, aircraft and airport terminals, and gambling casinos has been shown to yield an impressive number of survivors of cardiac arrest in ventricular fibrillation. Questions yet to be answered center on the appropriate disposition of AEDs in public access defibrillation settings, training and retraining issues, device maintenance, and collection of accurate data to document benefit and to identify areas of needed improvement or expansion of AED availability.

  10. Experimental and statistical approaches in method cross-validation to support pharmacokinetic decisions.

    Science.gov (United States)

    Thway, Theingi M; Ma, Mark; Lee, Jean; Sloey, Bethlyn; Yu, Steven; Wang, Yow-Ming C; Desilva, Binodh; Graves, Tom

    2009-04-05

    A case study of experimental and statistical approaches for cross-validating and examining the equivalence of two ligand binding assay (LBA) methods that were employed in pharmacokinetic (PK) studies is presented. The impact of changes in methodology based on the intended use of the methods was assessed. The cross-validation processes included an experimental plan, sample size selection, and statistical analysis with a predefined criterion of method equivalence. The two methods were deemed equivalent if the ratio of mean concentration fell within the 90% confidence interval (0.80-1.25). Statistical consideration of method imprecision was used to choose the number of incurred samples (collected from study animals) and conformance samples (spiked controls) for equivalence tests. The difference of log-transformed mean concentration and the 90% confidence interval for two methods were computed using analysis of variance. The mean concentration ratios of the two methods for the incurred and spiked conformance samples were 1.63 and 1.57, respectively. The 90% confidence limit was 1.55-1.72 for the incurred samples and 1.54-1.60 for the spiked conformance samples; therefore, the 90% confidence interval was not contained within the (0.80-1.25) equivalence interval. When the PK parameters of two studies using each of these two methods were compared, we determined that the therapeutic exposure, AUC((0-168)) and C(max), from Study A/Method 1 was approximately twice that of Study B/Method 2. We concluded that the two methods were not statistically equivalent and that the magnitude of the difference was reflected in the PK parameters in the studies using each method. This paper demonstrates the need for method cross-validation whenever there is a switch in bioanalytical methods, statistical approaches in designing the cross-validation experiments and assessing results, or interpretation of the impact of PK data.

  11. Gene association study with SVM, MLP and cross-validation for the diagnosis of diseases

    Institute of Scientific and Technical Information of China (English)

    Junying Zhang; Shenling Liu; Yue Wang

    2008-01-01

    Gene association study is one of the major challenges of biochip technology both for gene diagnosis where only a gene subset is responsible for some diseases, and for the treatment of the curse of dimensionality which occurs especially in DNA microarray datasets where there are more than thousands of genes and only a few number of experiments (samples). This paper presents a gene selection method by training linear support vector machine (SVM)/nonlinear MLP (multilayer perceptron) classifiers and testing them with cross-validation for finding a gene subset which is optimal/suboptimal for the diagnosis of binary/multiple disease types. Genes are selected with linear SVM classifier for the diagnosis of each binary disease types pair and tested by leave-one-out cross-validation; then, genes in the gene subset initialized by the union of them are deleted one by one by removing the gene which brings the greatest decrease of the generalization power, for samples, on the gene subset after removal, where generalization is measured by training MLPs with leave-one-out and leave-four-out cross-validations. The proposed method was tested with experiments on real DNA microarray MIT data and NCI data. The result shows that it outperforms conventional SNR method in the separability of the data with expression levels on selected genes. For real DNA microarray MIT/NCI data, which is composed of 7129/2308 effective genes with only 72/64 labeled samples belonging to 2/4 disease classes, only 11/6 genes are selected to be diagnostic genes. The selected genes are tested by the classification of samples on these genes with SVM/MLP with leave-one-out/both leave-one-out and leave-four-out cross-validations. The result of no misclassification indicates that the selected genes can be really considered as diagnostic genes for the diagnosis of the corresponding diseases.

  12. 75 FR 70015 - External Defibrillators; Public Workshop

    Science.gov (United States)

    2010-11-16

    ... of innovative AED features such as automated integration into local 9-1-1 systems. FDA will work with... consumers, to share perspectives. II. Topics for Discussion at the Public Workshop The public workshop will... signals, or enhance the use of external defibrillators? III. Transcripts Please be advised that as soon...

  13. [Cardiac Pacemakers, implantable defibrillators and IRM].

    Science.gov (United States)

    Frank, R; Hidden-Lucet, F; Himbert, C; Petitot, J C; Fontaine, G

    2003-04-01

    The IRM is formally contraindicated to the pacemaker and cardiac defibrillator wearers because of the risk of inhibition or inappropriate stimulations during the examination. However if the examination is essential, suitable programming of the apparatus and a constant monitoring of the heartbeat rate by a qualified doctor in cardiac stimulation must make it possible to avoid any accident.

  14. The association between biventricular pacing and cardiac resynchronization therapy-defibrillator efficacy when compared with implantable cardioverter defibrillator on outcomes and reverse remodelling

    DEFF Research Database (Denmark)

    Ruwald, Anne-Christine; Kutyifa, Valentina; Ruwald, Martin H;

    2015-01-01

    : Using Kaplan-Meier plots, we estimated the threshold of BIV pacing percentage needed for CRT-D to be superior to ICD on the end-point of heart failure (HF) or death in 1219 left bundle branch block (LBBB) patients in the MADIT-CRT trial. Patients were censored at the time of crossover. In multivariable...

  15. A shocking past: a walk through generations of defibrillation development.

    Science.gov (United States)

    Gutbrod, Sarah R; Efimov, Igor R

    2014-05-01

    Defibrillation is one of the most successful and widely recognized applications of electrotherapy. Yet the historical road to its first successful application in a patient and the innovative adaptation to an implantable device is marred with unexpected turns, political and personal setbacks, and public and scientific condemnation at each new idea. Driven by dedicated scientists and ever-advancing creative applications of new technologies, from electrocardiography to high density mapping and computational simulations, the field of defibrillation persevered and continued to evolve to the life-saving tool it is today. In addition to critical technological advances, the history of defibrillation is also marked by the plasticity of the theory of defibrillation. The advancing theories of success have propelled the campaign for reducing the defibrillation energy requirement, instilling hope in the development of a painless and harmless electrical defibrillation strategy.

  16. Raman fiber-optical method for colon cancer detection: Cross-validation and outlier identification approach

    Science.gov (United States)

    Petersen, D.; Naveed, P.; Ragheb, A.; Niedieker, D.; El-Mashtoly, S. F.; Brechmann, T.; Kötting, C.; Schmiegel, W. H.; Freier, E.; Pox, C.; Gerwert, K.

    2017-06-01

    Endoscopy plays a major role in early recognition of cancer which is not externally accessible and therewith in increasing the survival rate. Raman spectroscopic fiber-optical approaches can help to decrease the impact on the patient, increase objectivity in tissue characterization, reduce expenses and provide a significant time advantage in endoscopy. In gastroenterology an early recognition of malign and precursor lesions is relevant. Instantaneous and precise differentiation between adenomas as precursor lesions for cancer and hyperplastic polyps on the one hand and between high and low-risk alterations on the other hand is important. Raman fiber-optical measurements of colon biopsy samples taken during colonoscopy were carried out during a clinical study, and samples of adenocarcinoma (22), tubular adenomas (141), hyperplastic polyps (79) and normal tissue (101) from 151 patients were analyzed. This allows us to focus on the bioinformatic analysis and to set stage for Raman endoscopic measurements. Since spectral differences between normal and cancerous biopsy samples are small, special care has to be taken in data analysis. Using a leave-one-patient-out cross-validation scheme, three different outlier identification methods were investigated to decrease the influence of systematic errors, like a residual risk in misplacement of the sample and spectral dilution of marker bands (esp. cancerous tissue) and therewith optimize the experimental design. Furthermore other validations methods like leave-one-sample-out and leave-one-spectrum-out cross-validation schemes were compared with leave-one-patient-out cross-validation. High-risk lesions were differentiated from low-risk lesions with a sensitivity of 79%, specificity of 74% and an accuracy of 77%, cancer and normal tissue with a sensitivity of 79%, specificity of 83% and an accuracy of 81%. Additionally applied outlier identification enabled us to improve the recognition of neoplastic biopsy samples.

  17. Raman fiber-optical method for colon cancer detection: Cross-validation and outlier identification approach.

    Science.gov (United States)

    Petersen, D; Naveed, P; Ragheb, A; Niedieker, D; El-Mashtoly, S F; Brechmann, T; Kötting, C; Schmiegel, W H; Freier, E; Pox, C; Gerwert, K

    2017-06-15

    Endoscopy plays a major role in early recognition of cancer which is not externally accessible and therewith in increasing the survival rate. Raman spectroscopic fiber-optical approaches can help to decrease the impact on the patient, increase objectivity in tissue characterization, reduce expenses and provide a significant time advantage in endoscopy. In gastroenterology an early recognition of malign and precursor lesions is relevant. Instantaneous and precise differentiation between adenomas as precursor lesions for cancer and hyperplastic polyps on the one hand and between high and low-risk alterations on the other hand is important. Raman fiber-optical measurements of colon biopsy samples taken during colonoscopy were carried out during a clinical study, and samples of adenocarcinoma (22), tubular adenomas (141), hyperplastic polyps (79) and normal tissue (101) from 151 patients were analyzed. This allows us to focus on the bioinformatic analysis and to set stage for Raman endoscopic measurements. Since spectral differences between normal and cancerous biopsy samples are small, special care has to be taken in data analysis. Using a leave-one-patient-out cross-validation scheme, three different outlier identification methods were investigated to decrease the influence of systematic errors, like a residual risk in misplacement of the sample and spectral dilution of marker bands (esp. cancerous tissue) and therewith optimize the experimental design. Furthermore other validations methods like leave-one-sample-out and leave-one-spectrum-out cross-validation schemes were compared with leave-one-patient-out cross-validation. High-risk lesions were differentiated from low-risk lesions with a sensitivity of 79%, specificity of 74% and an accuracy of 77%, cancer and normal tissue with a sensitivity of 79%, specificity of 83% and an accuracy of 81%. Additionally applied outlier identification enabled us to improve the recognition of neoplastic biopsy samples. Copyright

  18. Batch effect confounding leads to strong bias in performance estimates obtained by cross-validation.

    Directory of Open Access Journals (Sweden)

    Charlotte Soneson

    Full Text Available With the large amount of biological data that is currently publicly available, many investigators combine multiple data sets to increase the sample size and potentially also the power of their analyses. However, technical differences ("batch effects" as well as differences in sample composition between the data sets may significantly affect the ability to draw generalizable conclusions from such studies.The current study focuses on the construction of classifiers, and the use of cross-validation to estimate their performance. In particular, we investigate the impact of batch effects and differences in sample composition between batches on the accuracy of the classification performance estimate obtained via cross-validation. The focus on estimation bias is a main difference compared to previous studies, which have mostly focused on the predictive performance and how it relates to the presence of batch effects.We work on simulated data sets. To have realistic intensity distributions, we use real gene expression data as the basis for our simulation. Random samples from this expression matrix are selected and assigned to group 1 (e.g., 'control' or group 2 (e.g., 'treated'. We introduce batch effects and select some features to be differentially expressed between the two groups. We consider several scenarios for our study, most importantly different levels of confounding between groups and batch effects.We focus on well-known classifiers: logistic regression, Support Vector Machines (SVM, k-nearest neighbors (kNN and Random Forests (RF. Feature selection is performed with the Wilcoxon test or the lasso. Parameter tuning and feature selection, as well as the estimation of the prediction performance of each classifier, is performed within a nested cross-validation scheme. The estimated classification performance is then compared to what is obtained when applying the classifier to independent data.

  19. The Screen-ICD trial. Screening for anxiety and cognitive therapy intervention for patients with implanted cardioverter defibrillator (ICD)

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Herning, Margrethe; Svendsen, Jesper Hastrup

    2016-01-01

    by Structured Clinical Interview for DSM Disorders (SCID). (3) Investigator-initiated randomised clinical superiority trial with blinded outcome assessment, with 1:1 randomisation to cognitive–behavioural therapy (CBT) performed by a cardiac nurse with CBT training, plus usual care or usual care alone...

  20. The Screen-ICD trial. Screening for anxiety and cognitive therapy intervention for patients with implanted cardioverter defibrillator (ICD)

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Herning, Margrethe; Svendsen, Jesper Hastrup;

    2016-01-01

    by Structured Clinical Interview for DSM Disorders (SCID). (3) Investigator-initiated randomised clinical superiority trial with blinded outcome assessment, with 1:1 randomisation to cognitive–behavioural therapy (CBT) performed by a cardiac nurse with CBT training, plus usual care or usual care alone...

  1. Automatic mode switching of a dual chamber implantable cardioverter-defibrillator induced by a ventricular escape rhythm.

    Science.gov (United States)

    Barold, S Serge; Van Heuverswyn, Frederic; Stroobandt, Roland X

    2013-01-01

    This report describes a form of group beating induced by a St Jude dual chamber ICD which interpreted a ventricular escape rhythm (with retrograde conduction) as premature ventricular complexes (PVC). These pacemaker-defined PVCs activated the atrial pace-PVC algorithm in 2 steps. 1. The postventricular atrial refractory period (PVARP) was terminated upon detecting a retrograde P wave within its unblanked portion, and 2. An atrial stimulus was released 330ms after the end of the PVARP. This response resulted in automatic mode switching because the 330ms interatrial interval was shorter than the atrial tachycardia detection interval. The arrhythmia may be considered to represent an unusual form of pacemaker escape-capture bigeminy.

  2. Incidence of ineffective safety margin testing (J) and efficacy of routine subcutaneous array insertion during implantable cardioverter defibrillator implantation.

    Science.gov (United States)

    Ohlow, Marc-Alexander; Roos, Marcus; Lauer, Bernward; Geller, J Christoph

    2016-01-01

    The purpose of this study was to assess (1) the incidence of safety margin testing J (SMT) and (2) the efficacy/safety of routinely adding a subcutaneous array (SQA) (Medtronic 6996SQ) for these patients. Patients with SMT smaller than a 10-J safety margin from maximum output were considered to have very high readings and underwent SQA insertion. These patients were compared with the rest of the patients who had acceptable SMT (≥10 J). A total of 616 patients underwent ICD implantation during the analysis period. Of those, 16 (2.6%) had SMT J. By univariate analysis, younger age, and non-ischemic cardiomyopathy, were all significant predictors of SMT J (p J; p J occur in about 2.6% of patients undergoing ICD implantation. SQA insertion corrects this problem without procedural/mid-term complications.

  3. Biomarker-based diagnosis of pacemaker and implantable cardioverter defibrillator pocket infections: A prospective, multicentre, case-control evaluation

    Science.gov (United States)

    Vrazic, Hrvoje; Haller, Bernhard; Braun, Siegmund; Petzold, Tobias; Ott, Ilka; Lennerz, Agnes; Michel, Jonathan; Blažek, Patrick; Deisenhofer, Isabel; Whittaker, Peter; Kolb, Christof

    2017-01-01

    Background The use of cardiac implantable electronic devices (CIED) has risen steadily, yet the rate of cardiac device infections (CDI) has disproportionately increased. Amongst all cardiac device infections, the pocket infection is the most challenging diagnosis. Therefore, we aimed to improve diagnosis of such pocket infection by identifying relevant biomarkers. Methods We enrolled 25 consecutive patients with invasively and microbiologically confirmed pocket infection. None of the patients had any confounding conditions. Pre-operative levels of 14 biomarkers were compared in infected and control (n = 50) patients. Our selected biomarkers included white blood cell count (WBC), C-reactive protein (CRP), procalcitonin (PCT), lipopolysaccharide binding protein, high-sensitivity C-reactive protein (HS-CRP), polymorphonuclear-elastase, presepsin, various interleukins, tumor necrosis factor α (TNF-α), and granulocyte macrophage colony-stimulating factor (GM-CSF). Results Of the 25 patients with isolated pocket infection (70±13years, 76% male, 40% ICDs), none presented with leukocytosis. In contrast, they had higher serum levels of HS-CRP (p = 0.019) and PCT (p = 0.010) than control patients. Median PCT-level was 0.06 ng/mL (IQR 0.03–0.07 ng/mL) in the study group versus 0.03 ng/mL (IQR 0.02–0.04 ng/mL) in controls. An optimized PCT cut-off value of 0.05 ng/mL suggests pocket infection with a sensitivity of 60% and specificity of 82%. In addition TNF-α- and GM-CSF-levels were lower in the study group. Other biomarkers did not differ between groups. Conclusion Diagnosis of isolated pocket infections requires clinical awareness, physical examination, evaluation of blood cultures and echocardiography assessment. Nevertheless, measurement of PCT- and HS-CRP-levels can aid diagnosis. However, no conclusion can be drawn from normal WBC-values. Clinical trial registration clinicaltrials.gov identifier: NCT01619267 PMID:28264059

  4. Risk of pacemaker or implantable cardioverter defibrillator after radiotherapy for early-stage breast cancer in Denmark, 1982-2005

    DEFF Research Database (Denmark)

    Rehammar, Jens Christian; Johansen, Jens Brock; Jensen, Maj-Britt;

    2016-01-01

    (RT). MATERIAL AND METHODS: All women treated for early-stage BC in Denmark from 1982 to 2005 were identified from the Danish Breast Cancer Cooperative Group. By record linkage to the Danish Pacemaker and ICD Registry information was retrieved on CIED implants subsequent to RT. Standardized incidence...

  5. Fast Electrocardiogram Amplifier Recovery after Defibrillation Shock

    Directory of Open Access Journals (Sweden)

    Ivan Dotsinsky

    2005-04-01

    Full Text Available A procedure for fast ECG amplifier recovery after defibrillation shocks was developed and simulated in the MATLAB environment. Exponentially decaying post-shock voltages have been recorded. Signals from the AHA database are taken and mixed with the recorded exponential disturbances. The algorithm applies moving averaging (comb filter on the compound input signal, thereby obtaining the samples of the disturbance. They are currently subtracted from the input signal. The results obtained show that its recovery is practically instantaneous.

  6. Legal aspects in implantable defibrillator extraction.

    Science.gov (United States)

    D'Ovidio, C; Costantini, S; Vellante, P; Carnevale, A

    2013-10-01

    At the Institute of Legal Medicine in Chieti, a case of iatrogenic superior vena cava perforation was observed during laser extraction of an infected biventricular implantable cardiac defibrillator. The presentation of this particular case represented a starting point for studying the occurrence of similar complications in literature, since their knowledge and understanding should induce resolution of any organisation problems, aid in increasing physicians' training and impose the availability of cardiac surgeons during such operations.

  7. Cross-validation analysis of bias models in Bayesian multi-model projections of climate

    Science.gov (United States)

    Huttunen, J. M. J.; Räisänen, J.; Nissinen, A.; Lipponen, A.; Kolehmainen, V.

    2017-03-01

    Climate change projections are commonly based on multi-model ensembles of climate simulations. In this paper we consider the choice of bias models in Bayesian multimodel predictions. Buser et al. (Clim Res 44(2-3):227-241, 2010a) introduced a hybrid bias model which combines commonly used constant bias and constant relation bias assumptions. The hybrid model includes a weighting parameter which balances these bias models. In this study, we use a cross-validation approach to study which bias model or bias parameter leads to, in a specific sense, optimal climate change projections. The analysis is carried out for summer and winter season means of 2 m-temperatures spatially averaged over the IPCC SREX regions, using 19 model runs from the CMIP5 data set. The cross-validation approach is applied to calculate optimal bias parameters (in the specific sense) for projecting the temperature change from the control period (1961-2005) to the scenario period (2046-2090). The results are compared to the results of the Buser et al. (Clim Res 44(2-3):227-241, 2010a) method which includes the bias parameter as one of the unknown parameters to be estimated from the data.

  8. Genoplivning med automatisk ekstern defibrillator på hospital

    DEFF Research Database (Denmark)

    Løfgren, Bo; Wahlgreen, Claus; Hoffmann, Anne Mette;

    2009-01-01

    Early defibrillation is a determinant of survival in cardiac arrest. We report a Danish case of successful in-hospital resuscitation using an automated external defibrillator (AED). This case illustrates important aspects of implementation of in-hospital use of an AED, i.e. location of the AED, e...

  9. Clinical practice of defibrillator implantation after myocardial infarction: impact of implant time: results from the PreSCD II Registry†

    Science.gov (United States)

    Völler, Heinz; Kamke, Wolfram; Klein, Helmut U.; Block, Michael; Reibis, Rona; Treusch, Sven; Contzen, Klaus; Wegscheider, Karl

    2011-01-01

    Aims Current guidelines recommend implantable cardioverter-defibrillator (ICD) therapy for primary prevention of sudden cardiac death in patients with the reduced left ventricular function (LVEF ≤30%) not earlier than 40 days after myocardial infarction (MI). The aim of the prospective Prevention of Sudden Cardiac Death II (PreSCD II) registry was to investigate the clinical practice of ICD therapy in post-MI patients and to assess the impact on survival. Methods and results 10 612 consecutive patients (61 ± 12 years, 76% male) were enrolled 4 weeks or later after MI in 19 cardiac rehabilitation centres in Germany from December 2002 to May 2005. All patients with left ventricular ejection fraction (LVEF) ≤40% (n = 952) together with a randomly selected group of patients with preserved left ventricular function (n = 1106) were followed for 36 months. Cox proportional hazard models were used to correlate ICD implantation and survival with baseline characteristics. Of all patients studied, 75.9% were enrolled within 4–8 weeks, 10.7% more than 1 year after MI. Pre-specified Group 1 with an LVEF ≤30% consisted of 269 patients (2.5%), Group 2 with LVEF 31–40% of 727 patients (6.9%), and Group 3 with LVEF >40% of 1148 randomly selected patients from the cohort of 9616 patients with preserved LV function. After 36 months, only 142 patients (6.9%) had received an ICD; 82 (31.7%) of Group 1, 49 (7%) of Group 2, and 11 (1%) in Group 3. The ICD was implanted in 47% of all patients within 1 year after their index MI. Implantable cardioverter-defibrillator patients were predominantly characterized by low ejection fraction, but also by several other independent risk factors. Patients who received an ICD had an adjusted 44% lower mortality (hazard ratio 0.56, 95% confidence intervals 0.32–1.01; P = 0.053) than comparable patients without ICD therapy. All cause mortality of ICD recipients was significantly lower if the ICD was implanted later than 11 months after acute

  10. A study to improve communication between clinicians and patients with advanced heart failure: methods and challenges behind the working to improve discussions about defibrillator management trial.

    Science.gov (United States)

    Goldstein, Nathan E; Kalman, Jill; Kutner, Jean S; Fromme, Erik K; Hutchinson, Mathew D; Lipman, Hannah I; Matlock, Daniel D; Swetz, Keith M; Lampert, Rachel; Herasme, Omarys; Morrison, R Sean

    2014-12-01

    We report the challenges of the Working to Improve Discussions About Defibrillator Management trial, our novel, multicenter trial aimed at improving communication between cardiology clinicians and their patients with advanced heart failure (HF) who have implantable cardioverter defibrillators (ICDs). The study objectives are (1) to increase ICD deactivation conversations, (2) to increase the number of ICDs deactivated, and (3) to improve psychological outcomes in bereaved caregivers. The unit of randomization is the hospital, the intervention is aimed at HF clinicians, and the patient and caregiver are the units of analysis. Three hospitals were randomized to usual care and three to intervention. The intervention consists of an interactive educational session, clinician reminders, and individualized feedback. We enroll patients with advanced HF and their caregivers, and then we regularly survey them to evaluate whether the intervention has improved communication between them and their HF providers. We encountered three implementation barriers. First, there were institutional review board concerns at two sites because of the palliative nature of the study. Second, we had difficulty in creating entry criteria that accurately identified an HF population at high risk of dying. Third, we had to adapt our entry criteria to the changing landscape of ventricular assist devices and cardiac transplant eligibility. Here we present our novel solutions to the difficulties we encountered. Our work has the ability to enhance conduct of future studies focusing on improving care for patients with advanced illness.

  11. Asymptotic optimality and efficient computation of the leave-subject-out cross-validation

    KAUST Repository

    Xu, Ganggang

    2012-12-01

    Although the leave-subject-out cross-validation (CV) has been widely used in practice for tuning parameter selection for various nonparametric and semiparametric models of longitudinal data, its theoretical property is unknown and solving the associated optimization problem is computationally expensive, especially when there are multiple tuning parameters. In this paper, by focusing on the penalized spline method, we show that the leave-subject-out CV is optimal in the sense that it is asymptotically equivalent to the empirical squared error loss function minimization. An efficient Newton-type algorithm is developed to compute the penalty parameters that optimize the CV criterion. Simulated and real data are used to demonstrate the effectiveness of the leave-subject-out CV in selecting both the penalty parameters and the working correlation matrix. © 2012 Institute of Mathematical Statistics.

  12. Error criteria for cross validation in the context of chaotic time series prediction.

    Science.gov (United States)

    Lim, Teck Por; Puthusserypady, Sadasivan

    2006-03-01

    The prediction of a chaotic time series over a long horizon is commonly done by iterating one-step-ahead prediction. Prediction can be implemented using machine learning methods, such as radial basis function networks. Typically, cross validation is used to select prediction models based on mean squared error. The bias-variance dilemma dictates that there is an inevitable tradeoff between bias and variance. However, invariants of chaotic systems are unchanged by linear transformations; thus, the bias component may be irrelevant to model selection in the context of chaotic time series prediction. Hence, the use of error variance for model selection, instead of mean squared error, is examined. Clipping is introduced, as a simple way to stabilize iterated predictions. It is shown that using the error variance for model selection, in combination with clipping, may result in better models.

  13. Variance Estimation Using Refitted Cross-validation in Ultrahigh Dimensional Regression

    CERN Document Server

    Fan, Jianqing; Hao, Ning

    2010-01-01

    Variance estimation is a fundamental problem in statistical modeling. In ultrahigh dimensional linear regressions where the dimensionality is much larger than sample size, traditional variance estimation techniques are not applicable. Recent advances on variable selection in ultrahigh dimensional linear regressions make this problem accessible. One of the major problems in ultrahigh dimensional regression is the high spurious correlation between the unobserved realized noise and some of the predictors. As a result, the realized noises are actually predicted when extra irrelevant variables are selected, leading to serious underestimate of the noise level. In this paper, we propose a two-stage refitted procedure via a data splitting technique, called refitted cross-validation (RCV), to attenuate the influence of irrelevant variables with high spurious correlations. Our asymptotic results show that the resulting procedure performs as well as the oracle estimator, which knows in advance the mean regression functi...

  14. Diversity Shrinkage: Cross-Validating Pareto-Optimal Weights to Enhance Diversity via Hiring Practices.

    Science.gov (United States)

    Song, Q Chelsea; Wee, Serena; Newman, Daniel A

    2017-07-27

    To reduce adverse impact potential and improve diversity outcomes from personnel selection, one promising technique is De Corte, Lievens, and Sackett's (2007) Pareto-optimal weighting strategy. De Corte et al.'s strategy has been demonstrated on (a) a composite of cognitive and noncognitive (e.g., personality) tests (De Corte, Lievens, & Sackett, 2008) and (b) a composite of specific cognitive ability subtests (Wee, Newman, & Joseph, 2014). Both studies illustrated how Pareto-weighting (in contrast to unit weighting) could lead to substantial improvement in diversity outcomes (i.e., diversity improvement), sometimes more than doubling the number of job offers for minority applicants. The current work addresses a key limitation of the technique-the possibility of shrinkage, especially diversity shrinkage, in the Pareto-optimal solutions. Using Monte Carlo simulations, sample size and predictor combinations were varied and cross-validated Pareto-optimal solutions were obtained. Although diversity shrinkage was sizable for a composite of cognitive and noncognitive predictors when sample size was at or below 500, diversity shrinkage was typically negligible for a composite of specific cognitive subtest predictors when sample size was at least 100. Diversity shrinkage was larger when the Pareto-optimal solution suggested substantial diversity improvement. When sample size was at least 100, cross-validated Pareto-optimal weights typically outperformed unit weights-suggesting that diversity improvement is often possible, despite diversity shrinkage. Implications for Pareto-optimal weighting, adverse impact, sample size of validation studies, and optimizing the diversity-job performance tradeoff are discussed. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  15. Accuracy of genome enabled prediction in a dairy cattle population using different cross-validation layouts

    Directory of Open Access Journals (Sweden)

    M. Angeles ePérez-Cabal

    2012-02-01

    Full Text Available The impact of extent of genetic relatedness on accuracy of genome-enabled predictions was assessed using a dairy cattle population and alternative cross-validation (CV strategies were compared. The CV layouts consisted of training and testing sets obtained from either random allocation of individuals (RAN or from a kernel-based clustering of individuals using the additive relationship matrix, to obtain two subsets that were as unrelated as possible (UNREL, as well as a layout based on stratification by generation (GEN. The UNREL layout decreased the average genetic relationships between training and testing animals but produced similar accuracies to the RAN design, which were about 15% higher than in the GEN setting. Results indicate that the CV structure can have an important effect on the accuracy of whole-genome predictions. However, the connection between average genetic relationships across training and testing sets and the estimated predictive ability is not straightforward, and may depend also on the kind of relatedness that exists between the two subsets and on the heritability of the trait. For high heritability traits, close relatives such as parents and full sibs make the greatest contributions to accuracy, which can be compensated by half-sibs or grandsires in the case of lack of close relatives. However, for the low heritability traits the inclusion of close relatives is crucial and including more relatives of various types in the training set tends to lead to greater accuracy. In practice, cross-validation designs should resemble the intended use of the predictive models, e.g. within or between family predictions, or within or across generation predictions, such that estimation of predictive ability is consistent with the actual application to be considered.

  16. Testing alternative ground water models using cross-validation and other methods

    Science.gov (United States)

    Foglia, L.; Mehl, S.W.; Hill, M.C.; Perona, P.; Burlando, P.

    2007-01-01

    Many methods can be used to test alternative ground water models. Of concern in this work are methods able to (1) rank alternative models (also called model discrimination) and (2) identify observations important to parameter estimates and predictions (equivalent to the purpose served by some types of sensitivity analysis). Some of the measures investigated are computationally efficient; others are computationally demanding. The latter are generally needed to account for model nonlinearity. The efficient model discrimination methods investigated include the information criteria: the corrected Akaike information criterion, Bayesian information criterion, and generalized cross-validation. The efficient sensitivity analysis measures used are dimensionless scaled sensitivity (DSS), composite scaled sensitivity, and parameter correlation coefficient (PCC); the other statistics are DFBETAS, Cook's D, and observation-prediction statistic. Acronyms are explained in the introduction. Cross-validation (CV) is a computationally intensive nonlinear method that is used for both model discrimination and sensitivity analysis. The methods are tested using up to five alternative parsimoniously constructed models of the ground water system of the Maggia Valley in southern Switzerland. The alternative models differ in their representation of hydraulic conductivity. A new method for graphically representing CV and sensitivity analysis results for complex models is presented and used to evaluate the utility of the efficient statistics. The results indicate that for model selection, the information criteria produce similar results at much smaller computational cost than CV. For identifying important observations, the only obviously inferior linear measure is DSS; the poor performance was expected because DSS does not include the effects of parameter correlation and PCC reveals large parameter correlations. ?? 2007 National Ground Water Association.

  17. Development of Pacing, Electrophysiology and Defibrillation in India

    Directory of Open Access Journals (Sweden)

    Mohan Nair

    2002-04-01

    rheumatic heart disease is generally of long duration and affects a younger population. Control of Rate versus Rhythm in Rheumatic Atrial Fibrillation Trial -‘CRRAFT’ conducted at Mumbai has documented the effectiveness of amiodarone in the treatment of rheumatic atrial fibrillation. Surgical RF pulmonary vein isolation using Thermaline Multi-Electrode Catheter [EP Technologies] has been done in 27 patients with rheumatic atrial fibrillation of more than one year duration. Lesions were as follows: bilateral pulmonary vein isolation, isolation of the left atrial appendage and connection lesion between left atrial appendage and pulmonary veins.Prof. K.K. Talwar, AIIMS, New Delhi and Dr. T.S. Kler, Escorts Heart Institute & Research Centre, New Delhi were the first to implant Implantable Cardioverter Defibrillators (ICD in India. Current annual ICD implantation rates stand at 60 per year.

  18. Cardiopulmonary resuscitation (CPR) plus delayed defibrillation versus immediate defibrillation for out-of-hospital cardiac arrest.

    Science.gov (United States)

    Huang, Yu; He, Qing; Yang, Li J; Liu, Guan J; Jones, Alexander

    2014-09-12

    Sudden cardiac arrest (SCA) is a common health problem associated with high levels of mortality. Cardiac arrest is caused by three groups of dysrhythmias: ventricular fibrillation (VF) or pulseless ventricular tachycardia (VT), pulseless electric activity (PEA) and asystole. The most common dysrhythmia found in out-of-hospital cardiac arrest (OHCA) is VF. During VF or VT, cardiopulmonary resuscitation (CPR) provides perfusion and oxygenation to the tissues, whilst defibrillation restores a viable cardiac rhythm. Early successful defibrillation is known to improve outcomes in VF/VT. However, it has been hypothesized that a period of CPR before defibrillation creates a more conducive physiological environment, increasing the likelihood of successful defibrillation. The order of priority of CPR versus defibrillation therefore remains in contention. As previous studies have remained inconclusive, we conducted a systematic review of available evidence in an attempt to draw conclusions on whether CPR plus delayed defibrillation or immediate defibrillation resulted in better outcomes in OHCA. To examine whether an initial one and one-half to three minutes of CPR administered by paramedics before defibrillation versus immediate defibrillation on arrival influenced survival rates, neurological outcomes or rates of return of spontaneous circulation (ROSC) in OHCA. We searched the following databases: the Cochrane Central Register of Controlled trials (CENTRAL) (2013, Issue 6); MEDLINE (Ovid) (1948 to May 2013); EMBASE (1980 to May 2013); the Institute for Scientific Information (ISI) Web of Science (1980 to May 2013) and the China Academic Journal Network Publishing Database (China National Knowledge Infrastructure (CNKI), 1980 to May 2013). We included studies published in all languages. We also searched the Current Controlled Trials and Clinical Trials databases for ongoing trials. We screened the references lists of studies included in our review against the reference

  19. The use of automated external defibrillators and public access defibrillators in the mountains: official guidelines of the international commission for mountain emergency medicine ICAR-MEDCOM.

    Science.gov (United States)

    Elsensohn, Fidel; Agazzi, Giancelso; Syme, David; Swangard, Michael; Facchetti, Gianluca; Brugger, Hermann

    2006-01-01

    In this article we propose guidelines for rational use of automated external defibrillators and public access defibrillators in the mountains. In cases of ventricular fibrillation and pulseless ventricular tachycardia, early defibrillation is the most effective therapy. Easy access to mountainous areas permits visitation by persons with high risks for sudden cardiac death, and medical trials show the benefit of exercising in moderate altitude. The introduction of public access defibrillators in popular areas in the mountains may lead to a reduction of fatal outcome of cardiac arrest. Public access defibrillators should be placed with priority in popular ski areas, in busy mountain huts and restaurants, at mass-participation events, and in remote but often-visited locations that do not have medical coverage. Automated external defibrillators should be available to first-responder groups and mountain-rescue teams. It is important that people know how to perform cardiopulmonary resuscitation and how to use public access defibrillators and automated external defibrillators.

  20. Cross-validation and hypothesis testing in neuroimaging: An irenic comment on the exchange between Friston and Lindquist et al.

    Science.gov (United States)

    Reiss, Philip T

    2015-08-01

    The "ten ironic rules for statistical reviewers" presented by Friston (2012) prompted a rebuttal by Lindquist et al. (2013), which was followed by a rejoinder by Friston (2013). A key issue left unresolved in this discussion is the use of cross-validation to test the significance of predictive analyses. This note discusses the role that cross-validation-based and related hypothesis tests have come to play in modern data analyses, in neuroimaging and other fields. It is shown that such tests need not be suboptimal and can fill otherwise-unmet inferential needs.

  1. Credible Intervals for Precision and Recall Based on a K-Fold Cross-Validated Beta Distribution.

    Science.gov (United States)

    Wang, Yu; Li, Jihong

    2016-08-01

    In typical machine learning applications such as information retrieval, precision and recall are two commonly used measures for assessing an algorithm's performance. Symmetrical confidence intervals based on K-fold cross-validated t distributions are widely used for the inference of precision and recall measures. As we confirmed through simulated experiments, however, these confidence intervals often exhibit lower degrees of confidence, which may easily lead to liberal inference results. Thus, it is crucial to construct faithful confidence (credible) intervals for precision and recall with a high degree of confidence and a short interval length. In this study, we propose two posterior credible intervals for precision and recall based on K-fold cross-validated beta distributions. The first credible interval for precision (or recall) is constructed based on the beta posterior distribution inferred by all K data sets corresponding to K confusion matrices from a K-fold cross-validation. Second, considering that each data set corresponding to a confusion matrix from a K-fold cross-validation can be used to infer a beta posterior distribution of precision (or recall), the second proposed credible interval for precision (or recall) is constructed based on the average of K beta posterior distributions. Experimental results on simulated and real data sets demonstrate that the first credible interval proposed in this study almost always resulted in degrees of confidence greater than 95%. With an acceptable degree of confidence, both of our two proposed credible intervals have shorter interval lengths than those based on a corrected K-fold cross-validated t distribution. Meanwhile, the average ranks of these two credible intervals are superior to that of the confidence interval based on a K-fold cross-validated t distribution for the degree of confidence and are superior to that of the confidence interval based on a corrected K-fold cross-validated t distribution for the

  2. A leave-one-out cross-validation SAS macro for the identification of markers associated with survival.

    Science.gov (United States)

    Rushing, Christel; Bulusu, Anuradha; Hurwitz, Herbert I; Nixon, Andrew B; Pang, Herbert

    2015-02-01

    A proper internal validation is necessary for the development of a reliable and reproducible prognostic model for external validation. Variable selection is an important step for building prognostic models. However, not many existing approaches couple the ability to specify the number of covariates in the model with a cross-validation algorithm. We describe a user-friendly SAS macro that implements a score selection method and a leave-one-out cross-validation approach. We discuss the method and applications behind this algorithm, as well as details of the SAS macro.

  3. Improving Defibrillation Efficiency in Area Schools.

    Science.gov (United States)

    Thomas, Vincent C; Shen, Jay J; Stanley, Ramona; Dahlke, Jeffrey; McPartlin, Sheri; Row, Lynn

    2016-07-01

    Sudden cardiac arrest (SCA) in the young is a rare event but the effects can be devastating. We sought to identify variables that would lead to an improvement in time to defibrillation (TDFB), a previously noted factor significantly influencing survival from cardiac arrest. During the 2013-2014 academic year, the Clark county school district performed quarterly drills to practice the coordinated automated external defibrillator (AED) response. Variables including school, AED carrier, and drill characteristics were measured to determine influence on TDFB. Schools were grouped by TDFB at a cutoff of three minutes. Characteristics were sought for schools with TDFB below three minutes. A mixed regression model taking into account repeated measures was created to determine which variables influenced TDFB. Time to overhead announcement, distance of AED from drill site, and time to setup AED were the variables influencing TDFB with statistical significance (P <.01). This study supports the notion of early recognition, announcement, and close proximity to an AED during a SCA to ensure an early TDFB. These results are consistent with basic life support and the chain of survival tenets of the American Heart Association. © 2016 Wiley Periodicals, Inc.

  4. Genoplivning med automatisk ekstern defibrillator på hospital

    DEFF Research Database (Denmark)

    Løfgren, Bo; Wahlgreen, Claus; Hoffmann, Anne Mette

    2009-01-01

    Early defibrillation is a determinant of survival in cardiac arrest. We report a Danish case of successful in-hospital resuscitation using an automated external defibrillator (AED). This case illustrates important aspects of implementation of in-hospital use of an AED, i.e. location of the AED......, education of the staff, systematic registration and data collection and technical aspects of AED use. If in-hospital AED implementation is carefully executed, its use may provide a safe and effective way of obtaining early defibrillation. Udgivelsesdato: 2009-Jan-26...

  5. [ILCOR recommendation on signage of automated external defibrillators (AEDs)].

    Science.gov (United States)

    Truhlár, A

    2010-05-01

    Early defibrillation is a determinant of survival in both out-of-hospital and in-hospital cardiac arrests from ventricular fibrillation and pulseless ventricular tachycardia. The review summarizes importance of early defibrillation with automated external defibrillators (AED) and presents the International Liaison Committee on Resuscitation (ILCOR) recommendation for universal AED sign. The aim of the recommendation is to unify the AED signs worldwide and to spread the knowledge of this. The public in general, but healthcare professionals particularly, should be able to recognize AED location and use the device immediately in case of cardiac arrest.

  6. Primärprävention des plötzlichen Herztodes mit implantierbaren Cardioverter-Defibrillatoren - Vernünftig oder MADIT?

    Directory of Open Access Journals (Sweden)

    Steinwender C

    2004-01-01

    Full Text Available Mehrere in jüngerer Zeit publizierte Studien belegen die Überlegenheit des implantierbaren Cardioverter-Defibrillators gegenüber einer medikamentösen Therapie in der Primärprävention des plötzlichen Herztodes. Die Kollektive dieser Untersuchungen bestanden aus den bekannten Hochrisikopatienten im Postinfarktstadium mit höher- bis höchstgradig eingeschränkter Linksventrikelfunktion. MADIT II war die erste Studie, die auf eine aufwendige rhythmologische Risikostratifizierung verzichtete und dennoch in sämtlichen Subgruppen einen therapeutischen Benefit durch die Defibrillatortherapie nachwies. Die sich hierdurch ergebende Evidenz fand rasch Eingang in die Richtlinien der großen kardiologischen Gesellschaften. Ungelöst bleiben vorerst zwei große Probleme: 1. die Frage der Finanzierung einer Umsetzung dieser Richtlinien; 2. die weitere Strategie zur effektiven Primärprävention des plötzlichen Herztodes, da durch oben genannte Studien nur ein kleiner Prozentsatz der möglichen künftigen Opfer abgedeckt wird. Als Lösungsansatz bietet sich eine kostengünstige, auf die Erfordernisse der Primärprävention abgestimmte Defibrillator-Technologie an, die gemeinsam mit einer Vereinfachung der Implantationsprozedur die Kosteneffektivität zugunsten der Prophylaxe beeinflussen kann. Weiters müssen zusätzlich große Anstrengungen zur Identifizierung von zukünftigen Opfern des plötzlichen Herztodes vor ihrer ersten Arrhythmie-Episode unternommen werden.

  7. Safety and interaction of patients with implantable cardiac defibrillators driving a hybrid vehicle.

    Science.gov (United States)

    Tondato, Fernando; Bazzell, Jane; Schwartz, Linda; Mc Donald, Bruce W; Fisher, Robert; Anderson, S Shawn; Galindo, Arcenio; Dueck, Amylou C; Scott, Luis R

    2017-01-15

    Electromagnetic interference (EMI) can affect the function of implantable cardioverter defibrillators (ICD). Hybrid electric vehicles (HEV) have increased popularity and are a potential source of EMI. Little is known about the in vivo effects of EMI generated by HEV on ICD. This study evaluated the in vivo interaction between EMI generated by HEV with ICD. Thirty patients (73±9 y/o; 80% male) with stable ICD function were exposed to EMI generated by a Toyota Prius Hybrid®. The vehicle was lifted above the ground, allowing safe changes in engine rotation and consequent variations in electromagnetic emission. EMI was measured (NARDA STS® model EHP-50C) and expressed in A/m (magnetic), Volts/m (electrical), and Hertz (frequency). Six positions were evaluated: driver, front passenger, right and left back seats, outside, at the back and front of the car. Each position was evaluated at idle, 30 mph, 60 mph and variable speeds (acceleration-deceleration-brake). All ICD devices were continuously monitored during the study. The levels of EMI generated were low (highest mean levels: 2.09A/m at right back seat at 30 mph; and 3.5V/m at driver seat at variable speeds). No episode of oversensing or inadvertent change in ICD programming was observed. It is safe for patients with ICD to interact with HEV. This is the first study to address this issue using an in vivo model. Further studies are necessary to evaluate the interaction of different models of HEV or electric engine with ICD or unipolar pacemakers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Pulmonary fluid overload monitoring in heart failure patients with single and dual chamber defibrillators.

    Science.gov (United States)

    Molon, Giulio; Zanotto, Gabriele; Rahue, Werner; Facchin, Domenico; Leoni, Loira; Morani, Giovanni; Calvi, Valeria; Catanzariti, Domenico; Costa, Alessandro; Zago, Lara; Comisso, Jennifer; Varbaro, Annamaria; Santini, Massimo

    2014-04-01

    Heart failure has a relevant healthcare impact. Monitoring of pulmonary fluid overload (PFO), measured by intrathoracic impedance, has been proposed to alert to heart failure worsening before symptoms become patent. The aim of our research was to evaluate whether PFO diagnostics reduce heart failure hospitalizations in heart failure patients receiving single-chamber or dual-chamber implantable cardioverter-defibrillator (ICD) for primary prevention of sudden death. Twenty-five Italian cardiological centers prospectively followed 221 ICD patients (86% men, 66 ± 11 years, 79% New York Heart Association II and left ventricular ejection fraction 28 ± 5%), of whom 123 received an ICD with PFO monitoring (diagnostics group) and 98 an ICD without such a diagnostics (control group). The association of each patient to a group was assigned a priori, independently of patients' characteristics but based on regional device allocation policies. Patient clinical characteristics and observation period were similar between groups. In a mean follow-up of 17 ± 11 months, heart failure hospitalizations or emergency-room admissions occurred in eight (7%) patients of the diagnostics group and in 16 of the control group (16%; P = 0.02), with an incidence, measured by Kaplan-Meier analysis, of 23% at 2 years and 34% at 3 years in patients of the control group compared with 8% at 2 and 3 years in patients of the diagnostics group (Log rank test P = 0.044). Our data show that in heart failure patients receiving single-chamber or dual-chamber ICD, the use of intrathoracic impedance monitoring is associated with a significant reduction of heart failure hospitalizations. Our results support the hypothesis that PFO diagnostics improve the likelihood of timely detection of heart failure worsening.

  9. Magnetic Resonance Imaging in Nondependent Pacemaker Patients with Pacemakers and Defibrillators with a Nearly Depleted Battery.

    Science.gov (United States)

    Okamura, Hideo; Padmanabhan, Deepak; Watson, Robert E; Dalzell, Connie; Acker, Nancy; Jondal, Mary; Romme, Abby L; Cha, Yong-Mei; Asirvatham, Samuel J; Felmlee, Joel P; Friedman, Paul A

    2017-05-01

    Magnetic resonance imaging (MRI) in patients with non-MRI-conditional cardiac implantable electronic devices (CIEDs) has been shown to be safe when performed under closely monitored protocols. However, the safety of MRI in patients with devices with a nearly depleted battery has not been reported. Prospective data were collected between January 2008 and May 2015 in patients with non-MRI-conditional CIEDs undergoing clinically indicated MRI under institutional protocol. Patients who were pacemaker dependent were excluded. Patients whose devices were at elective replacement indicator (ERI) at the time of MRI or close to ERI (ERI or replacement for battery depletion within 3 months of scan) were identified through database review and analyzed for clinical events. MRI scans (n = 569) were performed in 442 patients. Of these, we identified 13 scans performed with a nearly depleted battery in nine patients. All scans with implantable cardioverter defibrillators (ICDs, n = 9) were uneventful. However, two scans with pacemakers close to ERI resulted in a power-on-reset (PoR) event. One scan with a pacemaker close to ERI that was programmed to DOO mode reached ERI during MRI and automatically changed to VVI mode. Additionally, one scan with a pacemaker at ERI did not allow programming. All pacemakers with events were implanted before 2005. Patients with pacemakers and ICDs with a nearly depleted battery can safely undergo MRI when patients are not pacemaker dependent. Attention should be paid because old devices can result in PoR or ERI during MRI, which may lead to oversensing and inhibition of pacing. © 2017 Wiley Periodicals, Inc.

  10. A cross-validated cytoarchitectonic atlas of the human ventral visual stream.

    Science.gov (United States)

    Rosenke, M; Weiner, K S; Barnett, M A; Zilles, K; Amunts, K; Goebel, R; Grill-Spector, K

    2017-02-14

    The human ventral visual stream consists of several areas considered processing stages essential for perception and recognition. A fundamental microanatomical feature differentiating areas is cytoarchitecture, which refers to the distribution, size, and density of cells across cortical layers. Because cytoarchitectonic structure is measured in 20-micron-thick histological slices of postmortem tissue, it is difficult to assess (a) how anatomically consistent these areas are across brains and (b) how they relate to brain parcellations obtained with prevalent neuroimaging methods, acquired at the millimeter and centimeter scale. Therefore, the goal of this study was to (a) generate a cross-validated cytoarchitectonic atlas of the human ventral visual stream on a whole brain template that is commonly used in neuroimaging studies and (b) to compare this atlas to a recently published retinotopic parcellation of visual cortex (Wang, 2014). To achieve this goal, we generated an atlas of eight cytoarchitectonic areas: four areas in the occipital lobe (hOc1-hOc4v) and four in the fusiform gyrus (FG1-FG4) and tested how alignment technique affects the accuracy of the atlas. Results show that both cortex-based alignment (CBA) and nonlinear volumetric alignment (NVA) generate an atlas with better cross-validation performance than affine volumetric alignment (AVA). Additionally, CBA outperformed NVA in 6/8 of the cytoarchitectonic areas. Finally, the comparison of the cytoarchitectonic atlas to a retinotopic atlas shows a clear correspondence between cytoarchitectonic and retinotopic areas in the ventral visual stream. The successful performance of CBA suggests a coupling between cytoarchitectonic areas and macroanatomical landmarks in the human ventral visual stream, and furthermore that this coupling can be utilized towards generating an accurate group atlas. In addition, the coupling between cytoarchitecture and retinotopy highlights the potential use of this atlas in

  11. Some psychometric properties of the Chinese version of the Modified Dental Anxiety Scale with cross validation

    Directory of Open Access Journals (Sweden)

    Lahti Satu

    2008-03-01

    Full Text Available Abstract Objective To assess the factorial structure and construct validity for the Chinese version of the Modified Dental Anxiety Scale (MDAS. Materials and methods A cross-sectional survey was conducted in March 2006 from adults in the Beijing area. The questionnaire consisted of sections to assess for participants' demographic profile and dental attendance patterns, the Chinese MDAS and the anxiety items from the Hospital Anxiety and Depression Scale (HADS. The analysis was conducted in two stages using confirmatory factor analysis and structural equation modelling. Cross validation was tested with a North West of England comparison sample. Results 783 questionnaires were successfully completed from Beijing, 468 from England. The Chinese MDAS consisted of two factors: anticipatory dental anxiety (ADA and treatment dental anxiety (TDA. Internal consistency coefficients (tau non-equivalent were 0.74 and 0.86 respectively. Measurement properties were virtually identical for male and female respondents. Relationships of the Chinese MDAS with gender, age and dental attendance supported predictions. Significant structural parameters between the two sub-scales (negative affectivity and autonomic anxiety of the HADS anxiety items and the two newly identified factors of the MDAS were confirmed and duplicated in the comparison sample. Conclusion The Chinese version of the MDAS has good psychometric properties and has the ability to assess, briefly, overall dental anxiety and two correlated but distinct aspects.

  12. Comparison of cross-validation and bootstrap aggregating for building a seasonal streamflow forecast model

    Science.gov (United States)

    Schick, Simon; Rössler, Ole; Weingartner, Rolf

    2016-10-01

    Based on a hindcast experiment for the period 1982-2013 in 66 sub-catchments of the Swiss Rhine, the present study compares two approaches of building a regression model for seasonal streamflow forecasting. The first approach selects a single "best guess" model, which is tested by leave-one-out cross-validation. The second approach implements the idea of bootstrap aggregating, where bootstrap replicates are employed to select several models, and out-of-bag predictions provide model testing. The target value is mean streamflow for durations of 30, 60 and 90 days, starting with the 1st and 16th day of every month. Compared to the best guess model, bootstrap aggregating reduces the mean squared error of the streamflow forecast by seven percent on average. Thus, if resampling is anyway part of the model building procedure, bootstrap aggregating seems to be a useful strategy in statistical seasonal streamflow forecasting. Since the improved accuracy comes at the cost of a less interpretable model, the approach might be best suited for pure prediction tasks, e.g. as in operational applications.

  13. Enhancement of light propagation depth in skin: cross-validation of mathematical modeling methods.

    Science.gov (United States)

    Kwon, Kiwoon; Son, Taeyoon; Lee, Kyoung-Joung; Jung, Byungjo

    2009-07-01

    Various techniques to enhance light propagation in skin have been studied in low-level laser therapy. In this study, three mathematical modeling methods for five selected techniques were implemented so that we could understand the mechanisms that enhance light propagation in skin. The five techniques included the increasing of the power and diameter of a laser beam, the application of a hyperosmotic chemical agent (HCA), and the whole and partial compression of the skin surface. The photon density profile of the five techniques was solved with three mathematical modeling methods: the finite element method (FEM), the Monte Carlo method (MCM), and the analytic solution method (ASM). We cross-validated the three mathematical modeling results by comparing photon density profiles and analyzing modeling error. The mathematical modeling results verified that the penetration depth of light can be enhanced if incident beam power and diameter, amount of HCA, or whole and partial skin compression is increased. In this study, light with wavelengths of 377 nm, 577 nm, and 633 nm was used.

  14. The cross-validated AUC for MCP-logistic regression with high-dimensional data.

    Science.gov (United States)

    Jiang, Dingfeng; Huang, Jian; Zhang, Ying

    2013-10-01

    We propose a cross-validated area under the receiving operator characteristic (ROC) curve (CV-AUC) criterion for tuning parameter selection for penalized methods in sparse, high-dimensional logistic regression models. We use this criterion in combination with the minimax concave penalty (MCP) method for variable selection. The CV-AUC criterion is specifically designed for optimizing the classification performance for binary outcome data. To implement the proposed approach, we derive an efficient coordinate descent algorithm to compute the MCP-logistic regression solution surface. Simulation studies are conducted to evaluate the finite sample performance of the proposed method and its comparison with the existing methods including the Akaike information criterion (AIC), Bayesian information criterion (BIC) or Extended BIC (EBIC). The model selected based on the CV-AUC criterion tends to have a larger predictive AUC and smaller classification error than those with tuning parameters selected using the AIC, BIC or EBIC. We illustrate the application of the MCP-logistic regression with the CV-AUC criterion on three microarray datasets from the studies that attempt to identify genes related to cancers. Our simulation studies and data examples demonstrate that the CV-AUC is an attractive method for tuning parameter selection for penalized methods in high-dimensional logistic regression models.

  15. Density-preserving sampling: robust and efficient alternative to cross-validation for error estimation.

    Science.gov (United States)

    Budka, Marcin; Gabrys, Bogdan

    2013-01-01

    Estimation of the generalization ability of a classification or regression model is an important issue, as it indicates the expected performance on previously unseen data and is also used for model selection. Currently used generalization error estimation procedures, such as cross-validation (CV) or bootstrap, are stochastic and, thus, require multiple repetitions in order to produce reliable results, which can be computationally expensive, if not prohibitive. The correntropy-inspired density-preserving sampling (DPS) procedure proposed in this paper eliminates the need for repeating the error estimation procedure by dividing the available data into subsets that are guaranteed to be representative of the input dataset. This allows the production of low-variance error estimates with an accuracy comparable to 10 times repeated CV at a fraction of the computations required by CV. This method can also be used for model ranking and selection. This paper derives the DPS procedure and investigates its usability and performance using a set of public benchmark datasets and standard classifiers.

  16. Sound quality indicators for urban places in Paris cross-validated by Milan data.

    Science.gov (United States)

    Ricciardi, Paola; Delaitre, Pauline; Lavandier, Catherine; Torchia, Francesca; Aumond, Pierre

    2015-10-01

    A specific smartphone application was developed to collect perceptive and acoustic data in Paris. About 3400 questionnaires were analyzed, regarding the global sound environment characterization, the perceived loudness of some emergent sources and the presence time ratio of sources that do not emerge from the background. Sound pressure level was recorded each second from the mobile phone's microphone during a 10-min period. The aim of this study is to propose indicators of urban sound quality based on linear regressions with perceptive variables. A cross validation of the quality models extracted from Paris data was carried out by conducting the same survey in Milan. The proposed sound quality general model is correlated with the real perceived sound quality (72%). Another model without visual amenity and familiarity is 58% correlated with perceived sound quality. In order to improve the sound quality indicator, a site classification was performed by Kohonen's Artificial Neural Network algorithm, and seven specific class models were developed. These specific models attribute more importance on source events and are slightly closer to the individual data than the global model. In general, the Parisian models underestimate the sound quality of Milan environments assessed by Italian people.

  17. Population Validity and Cross-Validity: Applications of Distribution Theory for Testing Hypotheses, Setting Confidence Intervals, and Determining Sample Size

    Science.gov (United States)

    Algina, James; Keselman, H. J.

    2008-01-01

    Applications of distribution theory for the squared multiple correlation coefficient and the squared cross-validation coefficient are reviewed, and computer programs for these applications are made available. The applications include confidence intervals, hypothesis testing, and sample size selection. (Contains 2 tables.)

  18. A Large-Scale Empirical Evaluation of Cross-Validation and External Test Set Validation in (Q)SAR.

    Science.gov (United States)

    Gütlein, Martin; Helma, Christoph; Karwath, Andreas; Kramer, Stefan

    2013-06-01

    (Q)SAR model validation is essential to ensure the quality of inferred models and to indicate future model predictivity on unseen compounds. Proper validation is also one of the requirements of regulatory authorities in order to accept the (Q)SAR model, and to approve its use in real world scenarios as alternative testing method. However, at the same time, the question of how to validate a (Q)SAR model, in particular whether to employ variants of cross-validation or external test set validation, is still under discussion. In this paper, we empirically compare a k-fold cross-validation with external test set validation. To this end we introduce a workflow allowing to realistically simulate the common problem setting of building predictive models for relatively small datasets. The workflow allows to apply the built and validated models on large amounts of unseen data, and to compare the performance of the different validation approaches. The experimental results indicate that cross-validation produces higher performant (Q)SAR models than external test set validation, reduces the variance of the results, while at the same time underestimates the performance on unseen compounds. The experimental results reported in this paper suggest that, contrary to current conception in the community, cross-validation may play a significant role in evaluating the predictivity of (Q)SAR models.

  19. Cross-Validation of the Factor Structure of the Aberrant Behavior Checklist for Persons with Mental Retardation.

    Science.gov (United States)

    Bihm, Elson M.; Poindexter, Ann R.

    1991-01-01

    The original factor structure of the Aberrant Behavior Checklist was cross-validated with a U.S. sample of 470 persons with moderate to profound mental retardation (27 percent nonambulatory). Results replicated previous findings, suggesting that the original five factors (irritability, lethargy, stereotypic behavior, hyperactivity, and…

  20. Cross-validation of 3D particle tracking velocimetry for the study of granular flows down rotating chutes

    NARCIS (Netherlands)

    Shirsath, S.S.; Padding, J.T.; Clercx, H.J.H.; Kuipers, J.A.M.

    2015-01-01

    Three-dimensional particle tracking velocimetry (3D-PTV) is a promising technique to study the behavior of granular flows. The aim of this paper is to cross-validate 3D-PTV against independent or more established techniques, such as particle image velocimetry (PIV), electronic ultrasonic sensor meas

  1. Development of a current-controlled defibrillator for clinical tests.

    Science.gov (United States)

    Fischer, M; Schönegg, M; Schöchlin, J; Bolz, A

    2002-01-01

    The work presented here is only a part of the development for a new current-controlled defibrillator. In the diploma thesis "Development and construction of a current-controlled defibrillator for clinical tests" the most important part was the control and safety of the defibrillator. To ensure a safe circuit design, a risk-analysis and a Failure Mode and Effects Analysis (FMEA) were necessary. Another major part was the programming of a microcontroller in embedded C and a programmable logic device in Very High Speed Integrated Circuit Description Language (VHDL). The circuit had to be constructed, and the defibrillator was optically decoupled from the laptop for safety reasons. The waveform-data can be transmitted to the microcontroller from the laptop, and the logged data is then transmitted back.

  2. Automated external defibrillators: technical considerations and clinical promise.

    Science.gov (United States)

    Takata, T S; Page, R L; Joglar, J A

    2001-12-04

    Early defibrillation is the most important determinant of survival for victims of cardiac arrest due to ventricular fibrillation. The automated external defibrillator (AED) was developed as the result of the American Heart Association's Public Access Defibrillation initiative. The goal of this initiative is to place AEDs in strategic locations so that laypersons with minimal training could promptly defibrillate victims of cardiac arrest. Because of changes in design and the use of alternative waveforms for defibrillation, the modern AED is compact and portable, simple to use, and highly efficacious; in addition, it requires little maintenance. Automated external defibrillators have been used successfully by traditional and nontraditional responders as well as laypersons. In special environments, such as casinos and commercial aircraft, AEDs have performed particularly well. State and federal legislation has eased concerns about AED use by extending legal protection to AED users under Good Samaritan laws. Since the experience continues to be positive, AEDs are being used in increasingly diverse community locations, and public awareness is growing. The American Heart Association's initiative is progressing rapidly.

  3. Cross-validity of a portable glucose capillary monitors in relation to enzymatic spectrophotometer methods

    Directory of Open Access Journals (Sweden)

    William Alves Lima

    2006-09-01

    Full Text Available The glucose is an important substrate utilizaded during exercise. Accurate measurement of glucose is vital to obtain trustworthy results. The enzymatic spectrophotometer methods are generally considered the “goldstandard” laboratory procedure for measuring of glucose (GEnz, is time consuming, costly, and inappropriate for large scale field testing. Compact and portable glucose monitors (GAccu are quick and easy methods to assess glucose on large numbers of subjects. So, this study aimed to test the cross-validity of GAccu. The sample was composed of 107 men (aged= 35.4±10.7 years; stature= 168.4±6.9 cm; body mass= 73.4±11.2 kg; %fat= 20.9±8.3% – by dual energy x-ray absorptiometry. Blood for measuring fasting glucose was taken in basilar vein (Genz, Bioplus: Bio-2000 and in ring finger (GAccu: Accu-Chek© Advantage©, after a 12-hour overnight fast. GEnz was used as the criterion for cross-validity. Paired t-test shown differences (p RESUMO A glicose é um substrato importante utilizado durante o exercício físico. Medidas acuradas da glicose são fundamentais para a obtenção de resultados confiáveis. O método laboratorial de espectrofotometria enzimática geralmente é considerado o procedimento “padrão ouro” para medir a glicose (GEnz, o qual requer tempo, custo e é inapropriado para o uso em larga escala. Monitores portáteis de glicose (GAccu são rápidos e fáceis para medir a glicose em um grande número de sujeitos. Então, este estudo teve por objetivo testar a validade concorrente do GAccu. A amostra foi composta por 107 homens (idade= 35,4±10,7 anos; estatura= 168,4±6,9 cm; massa corporal= 73,4±11,2 kg; %gordura= 20,9±8,3% – por absortometria de raio-x de dupla energia. O sangue para mensurar a glicose em jejum foi tirado na veia basilar (Genz, Bioplus: Bio-2000 e no dedo anular (GAccu - Accu- Chek© Advantage©, depois de 12h de jejum noturno. O GEnz foi usado como critério para testar a validade

  4. Cross Validation Through Two-dimensional Solution Surface for Cost-Sensitive SVM.

    Science.gov (United States)

    Gu, Bin; Sheng, Victor; Tay, Keng; Romano, Walter; Li, Shuo

    2016-06-08

    Model selection plays an important role in cost-sensitive SVM (CS-SVM). It has been proven that the global minimum cross validation (CV) error can be efficiently computed based on the solution path for one parameter learning problems. However, it is a challenge to obtain the global minimum CV error for CS-SVM based on one-dimensional solution path and traditional grid search, because CS-SVM is with two regularization parameters. In this paper, we propose a solution and error surfaces based CV approach (CV-SES). More specifically, we first compute a two-dimensional solution surface for CS-SVM based on a bi-parameter space partition algorithm, which can fit solutions of CS-SVM for all values of both regularization parameters. Then, we compute a two-dimensional validation error surface for each CV fold, which can fit validation errors of CS-SVM for all values of both regularization parameters. Finally, we obtain the CV error surface by superposing K validation error surfaces, which can find the global minimum CV error of CS-SVM. Experiments are conducted on seven datasets for cost sensitive learning and on four datasets for imbalanced learning. Experimental results not only show that our proposed CV-SES has a better generalization ability than CS-SVM with various hybrids between grid search and solution path methods, and than recent proposed cost-sensitive hinge loss SVM with three-dimensional grid search, but also show that CV-SES uses less running time.

  5. The Cross-Validation in the Dialogue of Mental and Neuroscience

    Directory of Open Access Journals (Sweden)

    Drozdstoj St. Stoyanov

    2009-06-01

    Full Text Available The aim of the Validation Theory (VT as a meta-empirical construct is to introduce a new vista in the reorganization of the neuroscience, in its role of a science of the Mind-and-Brain unification. The present study focuses on existing discrepancies and contradictions between the methods of basic neurosciences and those prescribed by the psychological science. Our view is that these discrepancies are based on a high penetration of traditional neuroscience methods into the biological processes, coupled with low extrapolation (experimenting with animal models and vice versa for the psychological and psychopathological methods. A novel epistemological model for integrating psychological and neuroscientific knowledge is proposed. It is represented as a simultaneous investigation of the brain activity with penetrating high resolution functional Magnetic Resonance Imaging and in extenso application of set of psychological tests for exploring correspondence (cross-validation between their compounds. The proposed approach leads to a revision of the neuroscientific and psychological terms, methods and data, followed by a revision of their relative interplay. This would make possible a practical exchange of expensive but objective fMRI with the lower costing psychological instruments (effect of "minimization". The approaches proceeding from VT will infiltrate diagnostics and prevention in psychiatry. On a further stage the pharmaco-psychological monitoring will uncover new opportunities. This proofs' based research and practice represents an integral counterpart of the values-based mental health care. In conclusion VT is an evolutionary corner stone in order to traverse the stage of a Brain-Brain paradigm and to reach the point of development of the Mind-Brain paradigm.

  6. A psychometric investigation into the cross validation of an adaptation of the Ghiselli Predictability Index in personnel selection

    Directory of Open Access Journals (Sweden)

    Callie Theron

    2006-04-01

    Full Text Available Twigge, Theron, Steele and Meiring (2004 concluded that it is possible to develop a predictability index based on a concept originally proposed by Ghiselli (1956, 1960a, 1960b, which correlates with the real residuals derived from the regression of a criterion on one or more predictors. The addition of such a predictability index to the original regression model was found to produce a statistically significant increase in the correlation between the selection battery and the criterion. To be able to convincingly demonstrate the feasibility of enhancing selection utility through the use of predictability indices would, however, require the cross validation of the results obtained on a derivation sample on a holdout sample selected from the same population. The objective of this article consequently is to investigate the extent to which such a predictability index, developed on a validation sample, would successfully cross validate to a holdout sample. Encouragingly positive results were obtained. Recommendations for future research are made.

  7. Cross-validation analysis for genetic evaluation models for ranking in endurance horses.

    Science.gov (United States)

    García-Ballesteros, S; Varona, L; Valera, M; Gutiérrez, J P; Cervantes, I

    2017-06-21

    Ranking trait was used as a selection criterion for competition horses to estimate racing performance. In the literature the most common approaches to estimate breeding values are the linear or threshold statistical models. However, recent studies have shown that a Thurstonian approach was able to fix the race effect (competitive level of the horses that participate in the same race), thus suggesting a better prediction accuracy of breeding values for ranking trait. The aim of this study was to compare the predictability of linear, threshold and Thurstonian approaches for genetic evaluation of ranking in endurance horses. For this purpose, eight genetic models were used for each approach with different combinations of random effects: rider, rider-horse interaction and environmental permanent effect. All genetic models included gender, age and race as systematic effects. The database that was used contained 4065 ranking records from 966 horses and that for the pedigree contained 8733 animals (47% Arabian horses), with an estimated heritability around 0.10 for the ranking trait. The prediction ability of the models for racing performance was evaluated using a cross-validation approach. The average correlation between real and predicted performances across genetic models was around 0.25 for threshold, 0.58 for linear and 0.60 for Thurstonian approaches. Although no significant differences were found between models within approaches, the best genetic model included: the rider and rider-horse random effects for threshold, only rider and environmental permanent effects for linear approach and all random effects for Thurstonian approach. The absolute correlations of predicted breeding values among models were higher between threshold and Thurstonian: 0.90, 0.91 and 0.88 for all animals, top 20% and top 5% best animals. For rank correlations these figures were 0.85, 0.84 and 0.86. The lower values were those between linear and threshold approaches (0.65, 0.62 and 0.51). In

  8. Cross-validation of the reduced form of the Food Craving Questionnaire-Trait using confirmatory factor analysis

    OpenAIRE

    Luca eIani

    2015-01-01

    Objective: The Food Craving Questionnaire-Trait (FCQ-T) is commonly used to assess habitual food cravings among individuals. Previous studies have shown that a brief version of this instrument (FCQ-T-r) has good reliability and validity. This article is the first to use Confirmatory factor analysis to examine the psychometric properties of the FCQ-T-r in a cross-validation study. Method: Habitual food cravings, as well as emotion regulation strategies, affective states, and disordered eati...

  9. Awareness among resident doctors with regards to cardiac defibrillators

    Directory of Open Access Journals (Sweden)

    Garg Rakesh

    2010-01-01

    Full Text Available Background and Aims: Electrical defibrillation is the most important therapy for patients in cardiac arrest. The audit was aimed to assess awareness among residents with respect to routine preuse checking of cardiac defibrillators. Materials and Methods: The audit was conducted at a multispeciality tertiary care referral and teaching center by means of a printed questionnaire from anaesthesiology residents. A database was prepared and responses were analyzed. Results: Eighty resident doctors participated in the audit. Most (97.8% of the residents were sure of the presence of a defibrillator in the operation room (OR; 70% of postgraduates (PGs were aware of the location of the defibrillator in the OR as compared to 83.7% of the senior resident (SRs. Also, 32.1% residents routinely check the availability of a defibrillator. The working condition of the defibrillator was checked by 21.7% of the residents; 25.3% ensured delivery of the set charge. Further, 8.2% of residents ensured availability of both adult and paediatric paddles. About 27.8% of residents ensured the availability of appropriate conducting gel and 53.8% residents were of the opinion that the responsibility of checking the functioning and maintenance of the defibrillators lies with themselves. Some 22% thought that both doctors and technical staff should share the responsibility, while 19.5% opined that it should be the responsibility of the technical staff. Conclusion: All medical equipment is to be tested prior to initial use and periodically thereafter. An extensive, recurring training program, and continued attention to the training of clinical personnel is required to ensure that they are proficient in the operation and testing of specific defibrillator models in their work area. We conclude that apart from awareness of the use of the equipment we are using, its preuse testing is must. All resident doctors should be aware of the presence and adequate functioning of the

  10. Use a defibrillator, save a life

    CERN Multimedia

    Joannah Caborn Wengler

    2012-01-01

    With the work for Long Shutdown 1 looming on the horizon, the CERN Fire Brigade is anticipating a heavy workload: more people working at CERN means more call-outs. So the more trained first-aiders around to help out before the paramedics arrive, the better. Would you know what to do in a medical emergency?   It could happen at any time: two colleagues are having a coffee at work, when one suddenly clutches his or her chest and falls to the floor unconscious. What would you do? Run to find a first-aider? Call the ambulance and wait, finishing your coffee? Neither response is entirely correct. On Monday 11 June in Building 40 the CMS safety group, in collaboration with the Fire Brigade and the Medical Service, demonstrated the recommended, potentially life-saving response to cardiac arrest (see the video), including the correct use of a defibrillator, ten of which were recently installed in key CERN locations (the Bulletin reported).     “In countries where...

  11. Implantable defibrillators versus medical therapy for cardiac channelopathies.

    Science.gov (United States)

    McNamara, David A; Goldberger, Jeffrey J; Berendsen, Mark A; Huffman, Mark D

    2015-10-07

    Sudden cardiac death is a significant cause of mortality in both the US and globally. However, 5% to 15% of people with sudden cardiac death have no structural abnormalities, and most of these events are attributed to underlying cardiac ion channelopathies. Rates of cardiac ion channelopathy diagnosis are increasing. However, the optimal treatment for such people is poorly understood and current guidelines rely primarily on expert opinion. To compare the effect of implantable cardioverter defibrillators (ICD) with antiarrhythmic drugs or usual care in reducing the risk of all-cause mortality, fatal and non-fatal cardiovascular events, and adverse events in people with cardiac ion channelopathies. We searched the Cochrane Central Register of Controlled Trials (CENTRAL, 2015, Issue 6), EMBASE, MEDLINE, Conference Proceedings Citation Index - Science (CPCI-S), ClinicalTrials.gov, and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) in July 2015. We applied no language restrictions. We included all randomized controlled trials of people aged 18 years and older with ion channelopathies, including congenital long QT syndrome, congenital short QT syndrome, Brugada syndrome, or catecholaminergic polymorphic ventricular tachycardia. Participants must have been randomized to ICD implantation and compared to antiarrhythmic drug therapy or usual care. Two authors independently selected studies for inclusion and extracted the data. We included all-cause mortality, fatal and non-fatal cardiovascular events, and adverse events for our primary outcome analyses and non-fatal cardiovascular events, rates of inappropriate ICD firing, quality of life, and cost for our secondary outcome analyses. We calculated risk ratios (RR) and associated 95% confidence intervals (CIs) for dichotomous outcomes, both for independent and pooled study analyses. From the 468 references identified after removing duplicates, we found two trials comprising 86

  12. Marketing defibrillation training programs and bystander intervention support.

    Science.gov (United States)

    Sneath, Julie Z; Lacey, Russell

    2009-01-01

    This exploratory study identifies perceptions of and participation in resuscitation training programs, and bystanders' willingness to resuscitate cardiac arrest victims. While most of the study's participants greatly appreciate the importance of saving someone's life, many indicated that they did not feel comfortable assuming this role. The findings also demonstrate there is a relationship between type of victim and bystanders' willingness to intervene. Yet, bystander intervention discomfort can be overcome with cardiopulmonary resuscitation and defibrillation training, particularly when the victim is a coworker or stranger. Further implications of these findings are discussed and modifications to public access defibrillation (PAD) training programs' strategy and communications are proposed.

  13. Part 6: electrical therapies: automated external defibrillators, defibrillation, cardioversion, and pacing: 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care.

    Science.gov (United States)

    Link, Mark S; Atkins, Dianne L; Passman, Rod S; Halperin, Henry R; Samson, Ricardo A; White, Roger D; Cudnik, Michael T; Berg, Marc D; Kudenchuk, Peter J; Kerber, Richard E

    2010-11-02

    The recommendations for electrical therapies described in this section are designed to improve survival from SCA and life-threatening arrhythmias. Whenever defibrillation is attempted, rescuers must coordinate high-quality CPR with defibrillation to minimize interruptions in chest compressions and to ensure immediate resumption of chest compressions after shock delivery. The high first-shock efficacy of newer biphasic defibrillators led to the recommendation of single shocks plus immediate CPR instead of 3-shock sequences that were recommended prior to 2005 to treat VF. Further data are needed to refine recommendations for energy levels for defibrillation and cardioversion using biphasic waveforms.

  14. Cross-validation of species distribution models: removing spatial sorting bias and calibration with a null model.

    Science.gov (United States)

    Hijmans, Robert J

    2012-03-01

    Species distribution models are usually evaluated with cross-validation. In this procedure evaluation statistics are computed from model predictions for sites of presence and absence that were not used to train (fit) the model. Using data for 226 species, from six regions, and two species distribution modeling algorithms (Bioclim and MaxEnt), I show that this procedure is highly sensitive to "spatial sorting bias": the difference between the geographic distance from testing-presence to training-presence sites and the geographic distance from testing-absence (or testing-background) to training-presence sites. I propose the use of pairwise distance sampling to remove this bias, and the use of a null model that only considers the geographic distance to training sites to calibrate cross-validation results for remaining bias. Model evaluation results (AUC) were strongly inflated: the null model performed better than MaxEnt for 45% and better than Bioclim for 67% of the species. Spatial sorting bias and area under the receiver-operator curve (AUC) values increased when using partitioned presence data and random-absence data instead of independently obtained presence-absence testing data from systematic surveys. Pairwise distance sampling removed spatial sorting bias, yielding null models with an AUC close to 0.5, such that AUC was the same as null model calibrated AUC (cAUC). This adjustment strongly decreased AUC values and changed the ranking among species. Cross-validation results for different species are only comparable after removal of spatial sorting bias and/or calibration with an appropriate null model.

  15. The Decisions, Interventions, and Goals in ImplaNtable Cardioverter-DefIbrillator TherapY (DIGNITY) Pilot Study.

    Science.gov (United States)

    Kramer, Daniel B; Habtemariam, Daniel; Adjei-Poku, Yaw; Samuel, Michelle; Engorn, Diane; Reynolds, Matthew R; Mitchell, Susan L

    2017-09-22

    Implantable cardioverter-defibrillators (ICDs) are commonly implanted in older patients, including those with multiple comorbidities. There are few prospective studies assessing the clinical course and end-of-life circumstances for these patients. We prospectively followed 51 patients with ICDs for up to 18 months to longitudinally assess in terms of (1) advance care planning, (2) health status, (3) healthcare utilization, and (4) end-of-life circumstances through quarterly phone interviews and electronic medical record review. The mean age was 71.1±8.3, 74.5% were men, and 19.6% were non-white. Congestive heart failure was predominant (82.4%), as was chronic kidney disease (92%). At baseline, a total of 12% of subjects met criteria for major depression, and 78.4% met criteria for mild cognitive impairment. From this initial study cohort, 76% survived to 18 months and completed all follow-up interviews, 18% died, and 19% withdrew or were lost to follow-up. Though living will completion and healthcare proxy assignment were common (cumulative outcome at 18 months 88% and 98%, respectively), discussions of prognosis were uncommon (baseline, 9.8%; by 18 months, 22.7%), as were conversations regarding ICD deactivation (baseline, 15.7%; by 18 months, 25.5%). Five decedents with available data received shocks in the days immediately prior to death, including 3 of whom ultimately had their ICDs deactivated prior to death. We demonstrated the feasibility of prospective enrollment and follow-up of older, vulnerable ICD patients. Early findings suggest a high burden of cognitive and psychological impairment, poor communication with providers, and frequent shocks at the end of life. These findings will inform the design of a larger cohort study designed to further explore the experiences of living and dying with an ICD in this important patient population. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  16. [Automatic external defibrillator--mode of operation and clinical use].

    Science.gov (United States)

    Wieneke, H; Konorza, T; Breuckmann, F; Reinsch, N; Erbel, R

    2008-10-01

    Every year about 100,000 persons die from sudden cardiac death (SCD) in Germany. Although many efforts have been undertaken, mortality remains high. Only 2 - 10% of patients with out-off hospital SCD can finally be discharged from hospital after resuscitation. Observational studies show that ventricular fibrillation and ventricular tachycardia are the primary arrhythmias underlying SCD. For both arrhythmias the main determinant for survival is the time between onset and termination by defibrillation. The chance of survival declines by 10% for every minute of delay. These findings prompted the concept of early defibrillation by first responders. Many studies have shown that non-medical professionals, like police men, firemen or security officers, often arrive at the patient more early than emergency medical service. Thus, "smart" automated external defibrillators (AEDs), designed to identify VT/VF and prompt the user when to deliver a shock were introduced. These devices allow lay rescuers to terminate ventricular arrhythmias before the arrival of medical professionals. By this approach the time to defibrillation could be reduced and a significant reduction in mortality could be documented in selected situation. These encouraging results initialled the installation of AED at public places like aircrafts, airports, underground stations and shopping males. Due to the success of this approach doctors are more and more confronted with questions about technical details, reliability and cost effectiveness of these devices. The present review should give an overview about the current studies and guidelines.

  17. Advantage of four-electrode over two-electrode defibrillators

    Science.gov (United States)

    Bragard, J.; Šimić, A.; Laroze, D.; Elorza, J.

    2015-12-01

    Defibrillation is the standard clinical treatment used to stop ventricular fibrillation. An electrical device delivers a controlled amount of electrical energy via a pair of electrodes in order to reestablish a normal heart rate. We propose a technique that is a combination of biphasic shocks applied with a four-electrode system rather than the standard two-electrode system. We use a numerical model of a one-dimensional ring of cardiac tissue in order to test and evaluate the benefit of this technique. We compare three different shock protocols, namely a monophasic and two types of biphasic shocks. The results obtained by using a four-electrode system are compared quantitatively with those obtained with the standard two-electrode system. We find that a huge reduction in defibrillation threshold is achieved with the four-electrode system. For the most efficient protocol (asymmetric biphasic), we obtain a reduction in excess of 80% in the energy required for a defibrillation success rate of 90%. The mechanisms of successful defibrillation are also analyzed. This reveals that the advantage of asymmetric biphasic shocks with four electrodes lies in the duration of the cathodal and anodal phase of the shock.

  18. 21 CFR 870.5310 - Automated external defibrillator.

    Science.gov (United States)

    2010-04-01

    ... device with a rhythm recognition detection system that delivers into a 50 ohm test load an electrical shock of a maximum of 360 joules of energy used for defibrillating (restoring normal heart rhythm) the atria or ventricles of the heart. An AED analyzes the patient's electrocardiogram, interprets...

  19. Incidence and causes of inappropriate detection and therapy by implantable defibrillators of cardioversion in patients with ventricular tachyarrhythmia

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Background Implantable cardioverter defibrillator (ICD) is the only effective therapy in patients with life threatening ventricular arrhythmias. Inappropriate detection and therapy by ICDs are the most common causes of side effects that affect the quality of life in ICD recipients. This study evaluated the incidence and causes of inappropriate detection and therapy by ICDs in patients in our hospital.Methods From January 2000 to December 2005, fifty patients who received ICD implantation for ventricular arrhythmias for prevention of sudden cardiac death were evaluated in this study. Each ICD was programmed using clinical arrhythmic and cardiac data of the patient before discharge. Patients were followed up by standard schedule after implantation and all data retrieved from each device were collected and saved for further analysis. Results No arrhythmic event was detected in 12/50 (24%) patients during the period of follow-up. Among the remaining patients, 11 (22%) experienced inappropriate detections and therapies during follow-up in this study. ICD detected 383 ventricular tachyarrhythmia (VT) and 108 ventricular fibrillation (VF) episodes and delivered 678 therapies. In VT group, ICD delivered 413 antitachycardiac pacings (ATPs) and 118 shocks, among which 78 ATPs and 9 shocks were initiated by 55/383 (14.3%) inappropriate detections. In VF group ICD delivered 147 shocks, among which 56 shocks were initiated by 28/108 (26.9%) inappropriate detections. Overall, more than 50% of these episodes were caused by atrial fibrillation (AF) with rapid ventricular response, followed by electromagnetic or myopotential interference. In addition, most inappropriate therapies occurred within one year after ICD implantation.Conclusions About one fifth of patients experienced ICD inappropriate detection and therapy after implantation. The main cause was AF with rapid ventricular response, followed by electromagnetic or myopotential interference.

  20. Increased incidence of life-threatening ventricular arrhythmias in implantable defibrillator patients after the World Trade Center attack.

    Science.gov (United States)

    Steinberg, Jonathan S; Arshad, Aysha; Kowalski, Marcin; Kukar, Atul; Suma, Valentin; Vloka, Margot; Ehlert, Frederick; Herweg, Bengt; Donnelly, Jacqueline; Philip, Julie; Reed, George; Rozanski, Alan

    2004-09-15

    This study was designed to evaluate whether the destruction of the World Trade Center (WTC) on September 11, 2001 (9/11), led to an increased frequency of ventricular arrhythmias among patients fitted with an implantable cardioverter-defibrillator (ICD). The WTC attack induced psychological distress. Because ICDs store all serious arrhythmias for months, the attack provided a unique opportunity to compare pre- and post-9/11 frequencies of potentially lethal arrhythmias among ICD patients. Two hundred consecutive ICD patients who presented for regularly scheduled follow-up to six affiliated clinics were recruited into this observational study. The electrograms stored in the ICDs for the three months before 9/11 and 13 months thereafter were scrutinized in a blinded manner (relative to date) for all ventricular tachyarrhythmias (tachycardia or fibrillation) triggering ICD therapy. The frequency of tachyarrhythmias increased significantly for the 30 days post-9/11 (p = 0.004) relative to all other months between May 2001 and October 2002. In the 30 days post-9/11, 16 patients (8%) demonstrated tachyarrhythmias, compared with only seven (3.5%) in the preceding 30 days, representing a 2.3-fold increase in risk (95% confidence interval 1.1 to 4.9; p = 0.03). The first arrhythmic event did not occur for three days following 9/11, with events accumulating in a progressive non-clustered pattern. Ventricular arrhythmias increased by more than twofold among ICD patients following the WTC attack. The delay in onset and the non-clustered pattern of these events differ sharply from effects following other disasters, suggesting that subacute stress may have served to promote this arrhythmogenesis.

  1. Enhanced risk profiling of implanted defibrillator shocks with circulating SCN5A mRNA splicing variants: a pilot trial.

    Science.gov (United States)

    Gao, Ge; Brahmanandam, Vikram; Raicu, Mihai; Gu, Lianzhi; Zhou, Li; Kasturirangan, Srinivasan; Shah, Anish; Negi, Smita I; Wood, Melissa R; Desai, Ankit A; Tatooles, Antone; Schwartz, Alan; Dudley, Samuel C

    2014-06-03

    The aim of this study was to determine the association of SCN5A cardiac sodium (Na(+)) channel mRNA splice variants in white blood cells (WBCs) with risk of arrhythmias in heart failure (HF). HF is associated with upregulation of two cardiac SCN5A mRNA splice variants that encode prematurely truncated, nonfunctional Na(+) channels. Because circulating WBCs demonstrate similar SCN5A splicing patterns, we hypothesized that these WBC-derived splice variants might further stratify patients with HF who are at risk for arrhythmias. Simultaneously obtained myocardial core samples and WBCs were compared for SCN5A variants C (VC) and D (VD). Circulating variant levels were compared among patients with HF, divided into three groups: HF without an implantable cardioverter-defibrillator (ICD), HF with an ICD without appropriate intervention, and HF with an ICD with appropriate intervention. Myocardial tissue-derived SCN5A variant expression levels strongly correlated with circulating WBC samples for both VC and VD variants (r = 0.78 and 0.75, respectively). After controlling for covariates, patients with HF who had received an appropriate ICD intervention had higher expression levels of both WBC-derived SCN5A variants compared with patients with HF with ICDs who had not received appropriate ICD intervention (odds ratio, 3.25; 95% CI, 1.64-6.45; p = 0.001). Receiver operating characteristic analysis revealed that circulating SCN5A variant levels were highly associated with the risk for appropriate ICD intervention (area under the curve ≥0.97). Circulating expression levels of SCN5A variants were strongly associated with myocardial tissue levels. Furthermore, circulating variant levels were correlative with arrhythmic risk as measured by ICD events in an HF population within 1 year. (Sodium Channel Splicing in Heart Failure Trial [SOCS-HEFT]; NCT01185587). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  2. Examination of Random Forest Performance Results Generating Different Number of Trees and Changing ''k'' Parameter in Cross Validation

    Directory of Open Access Journals (Sweden)

    Songul CINAROGLU

    2015-10-01

    Full Text Available Objective: Random Forest (RF is one of machine learning techniques which is used for classification and regression with generating number of trees. There is a debate in the literature about how generating different number of trees reflects classification performance of this method. For this reason the aim of this study is to observe RF performance results by generating different number of trees and changing ''k'' parameter in cross validation while classifying OECD countries according to health expenditures. Material and Methods: In this dataset k-fold cross validation was implemented and Mann Whitney U test was used whether there is a difference in RF performance results using AUC when ''k'' parameter was high (k≥13 or low (k˂13 and while generating different number of trees (50, 100, 150, 200, 250. Results: Results of this study shows that generating different number of trees in RF not makes any significant changes (p˃0.05 in performance results. It was seen that perceived health status was a variable which has more information gain for predicting health expenditures. Conclusion: It is advisable for future studies related with this subject to examine performance results of different datasets which are in different types and sizes.

  3. In Vivo Tracking of Murine Adipose Tissue-Derived Multipotent Adult Stem Cells and Ex Vivo Cross-Validation

    Directory of Open Access Journals (Sweden)

    Chiara Garrovo

    2013-01-01

    Full Text Available Stem cells are characterized by the ability to renew themselves and to differentiate into specialized cell types, while stem cell therapy is believed to treat a number of different human diseases through either cell regeneration or paracrine effects. Herein, an in vivo and ex vivo near infrared time domain (NIR TD optical imaging study was undertaken to evaluate the migratory ability of murine adipose tissue-derived multipotent adult stem cells [mAT-MASC] after intramuscular injection in mice. In vivo NIR TD optical imaging data analysis showed a migration of DiD-labelled mAT-MASC in the leg opposite the injection site, which was confirmed by a fibered confocal microendoscopy system. Ex vivo NIR TD optical imaging results showed a systemic distribution of labelled cells. Considering a potential microenvironmental contamination, a cross-validation study by multimodality approaches was followed: mAT-MASC were isolated from male mice expressing constitutively eGFP, which was detectable using techniques of immunofluorescence and qPCR. Y-chromosome positive cells, injected into wild-type female recipients, were detected by FISH. Cross-validation confirmed the data obtained by in vivo/ex vivo TD optical imaging analysis. In summary, our data demonstrates the usefulness of NIR TD optical imaging in tracking delivered cells, giving insights into the migratory properties of the injected cells.

  4. Fear factors: cross validation of specific phobia domains in a community-based sample of African American adults.

    Science.gov (United States)

    Chapman, L Kevin; Vines, Lauren; Petrie, Jenny

    2011-05-01

    The current study attempted a cross-validation of specific phobia domains in a community-based sample of African American adults based on a previous model of phobia domains in a college student sample of African Americans. Subjects were 100 African American community-dwelling adults who completed the Fear Survey Schedule-Second Edition (FSS-II). Domains of fear were created using a similar procedure as the original, college sample of African American adults. A model including all of the phobia domains from the FSS-II was initially tested and resulted in poor model fit. Cross-validation was subsequently attempted through examining the original factor pattern of specific phobia domains from the college sample (Chapman, Kertz, Zurlage, & Woodruff-Borden, 2008). Data from the current, community based sample of African American adults provided poor fit to this model. The trimmed model for the current sample included the animal and social anxiety factors as in the original model. The natural environment-type specific phobia factor did not provide adequate fit for the community-based sample of African Americans. Results indicated that although different factor loading patterns of fear may exist among community-based African Americans as compared to African American college students, both animal and social fears are nearly identical in both groups, indicating a possible cultural homogeneity for phobias in African Americans. Potential explanations of these findings and future directions are discussed.

  5. Bayesian cross-validation for model evaluation and selection, with application to the North American Breeding Bird Survey

    Science.gov (United States)

    Link, William; Sauer, John R.

    2016-01-01

    The analysis of ecological data has changed in two important ways over the last 15 years. The development and easy availability of Bayesian computational methods has allowed and encouraged the fitting of complex hierarchical models. At the same time, there has been increasing emphasis on acknowledging and accounting for model uncertainty. Unfortunately, the ability to fit complex models has outstripped the development of tools for model selection and model evaluation: familiar model selection tools such as Akaike's information criterion and the deviance information criterion are widely known to be inadequate for hierarchical models. In addition, little attention has been paid to the evaluation of model adequacy in context of hierarchical modeling, i.e., to the evaluation of fit for a single model. In this paper, we describe Bayesian cross-validation, which provides tools for model selection and evaluation. We describe the Bayesian predictive information criterion and a Bayesian approximation to the BPIC known as the Watanabe-Akaike information criterion. We illustrate the use of these tools for model selection, and the use of Bayesian cross-validation as a tool for model evaluation, using three large data sets from the North American Breeding Bird Survey.

  6. Bayesian cross-validation for model evaluation and selection, with application to the North American Breeding Bird Survey.

    Science.gov (United States)

    Link, William A; Sauer, John R

    2016-07-01

    The analysis of ecological data has changed in two important ways over the last 15 years. The development and easy availability of Bayesian computational methods has allowed and encouraged the fitting of complex hierarchical models. At the same time, there has been increasing emphasis on acknowledging and accounting for model uncertainty. Unfortunately, the ability to fit complex models has outstripped the development of tools for model selection and model evaluation: familiar model selection tools such as Akaike's information criterion and the deviance information criterion are widely known to be inadequate for hierarchical models. In addition, little attention has been paid to the evaluation of model adequacy in context of hierarchical modeling, i.e., to the evaluation of fit for a single model. In this paper, we describe Bayesian cross-validation, which provides tools for model selection and evaluation. We describe the Bayesian predictive information criterion and a Bayesian approximation to the BPIC known as the Watanabe-Akaike information criterion. We illustrate the use of these tools for model selection, and the use of Bayesian cross-validation as a tool for model evaluation, using three large data sets from the North American Breeding Bird Survey.

  7. Cross-validation of the reduced form of the Food Craving Questionnaire-Trait using confirmatory factor analysis

    Directory of Open Access Journals (Sweden)

    Luca eIani

    2015-04-01

    Full Text Available Objective: The Food Craving Questionnaire-Trait (FCQ-T is commonly used to assess habitual food cravings among individuals. Previous studies have shown that a brief version of this instrument (FCQ-T-r has good reliability and validity. This article is the first to use Confirmatory factor analysis to examine the psychometric properties of the FCQ-T-r in a cross-validation study.Method: Habitual food cravings, as well as emotion regulation strategies, affective states and disordered eating behaviors, were investigated in two independent samples of non-clinical adult volunteers (Sample 1: N = 368; Sample 2: N = 246. Confirmatory factor analyses were conducted to simultaneously test model fit statistics and dimensionality of the instrument. FCQ-T-r reliability was assessed by computing the composite reliability coefficient. Results: Analysis supported the unidimensional structure of the scale and fit indices were acceptable for both samples. The FCQ-T-r showed excellent reliability and moderate to high correlations with negative affect and disordered eating. Conclusions: Our results indicate that the FCQ-T-r scores can be reliably used to assess habitual cravings in an Italian non-clinical sample of adults. The robustness of these results is tested by a cross-validation of the model using two independent samples. Further research is required to expand on these findings, particularly in children and adolescents.

  8. Preliminary Development of an Informational Media Use Measure for Patients with Implanted Defibrillators: Toward a Model of Social-Ecological Assessment of Patient Education and Support.

    Science.gov (United States)

    Knoepke, Christopher E; Matlock, Daniel D

    2017-05-31

    Social work interventions in health care, particularly those that involve working with people being treated for chronic and life-threatening conditions, frequently involve efforts to educate patients about their disease, treatment options, safety planning, medical adherence, and other associated issues. Despite an intuitive notion that patients access information about all of these issues through a variety of media-both inside and outside the clinical encounter, created by professionals and by others-there currently exists no validated means of assessing patients' use of these forms of information. To address this gap, authors first created candidate item measures with input from both physicians and a small group of diverse patients who currently have an implantable cardioverter defibrillator (ICD), a sophisticated cardiac device for which a trajectory model of social work intervention was recently outlined. Authors then surveyed a group of 205 individuals who have these devices, assessing their use of various media to learn about ICDs. They then conducted factor and item analysis to refine and remove poorly performing items while delineating forms of media use by type. The resultant preliminary measure of informational media use can be further refined and adapted for use with any clinical population. © 2017 National Association of Social Workers.

  9. Predictive value of programmed ventricular stimulation in patients with ischaemic cardiomyopathy: implications for the selection of candidates for an implantable defibrillator.

    Science.gov (United States)

    De Ferrari, Gaetano M; Rordorf, Roberto; Frattini, Folco; Petracci, Barbara; De Filippo, Paolo; Landolina, Maurizio

    2007-12-01

    The present study assessed the role of programmed ventricular stimulation (PVS) in risk stratification of patients with ischaemic cardiomyopathy (ICM), candidates for implantable cardioverter-defibrillator (ICD). Consecutive patients with ICM and LVEF < or = 40% (n = 106, age 61 +/- 7 years, LVEF 27 +/- 7%) underwent PVS. This was considered positive in case of inducibility of monomorphic ventricular tachycardia (VT) with < or =3 extrastimuli; polymorphic VT, ventricular fibrillation (VF), and fast monomorphic VT (CL < or = 230 ms) with < or =2 extrastimuli. Primary end-point was the combination of arrhythmic death and VF requiring ICD shock. Forty-nine patients (46%) were inducible at PVS; 74 (70%) were implanted with ICD. During a 24-month follow-up, the primary end-point occurred more frequently in positive PVS patients among the overall population, among patients with LVEF < or = 30% (n = 80) and among patients with an ICD. The negative predictive value of PVS was 96% in each group. In the overall population, both PVS (HR 7.32, 95% CI 1.6-32) and LVEF (HR 4.59, 95% CI 1.6-13) predicted the primary end-point. PVS may still have a role in predicting the arrhythmic risk in patients with ICM. A negative PVS identifies a subgroup with a very low risk of arrhythmic events even in patients with LVEF < or = 30%.

  10. Estudo clínico de um sistema cardioversor-desfibrilador implantável que apresenta limiares de desfibrilação baixos usando eletrodos de estrutura fractal Clinical studies of an implantable cardioversor - defibrillators system providing low defibrillation thresholds as well as high signal amplitudes due to fractal coated electrodes

    Directory of Open Access Journals (Sweden)

    Fernando A. LUCCHESE

    1999-01-01

    Full Text Available Em função do contínuo desenvolvimento tecnológico, a geração atual de cardioversores-desfibriladores implantáveis (CDI garante um alto grau de segurança e eficiência na detecção e reversão de taquiarritmias ventriculares. O presente trabalho sumariza os resultados clínicos obtidos com 1058 CDI de câmara única (Phylax 6, Phylax XM, Biotronik utilizando eletrodo único e tecnologia de carcaça ativa, SPS e Kainox RV (com uma mola intracavitária de choque, SL-ICD e Kainox SL (com duas molas intracavitárias de choque, Biotronik. Na quase totalidade dos pacientes, com exceção de 3 (> 99%, foram obtidos limiares de desfibrilação com baixa energia usando apenas um eletrodo transvenoso. Isto tem permitido substituir o teste de limiar de desfibrilação usual por um teste simples durante o implante, afim de minimizar os riscos associados com repetidas induções de fibrilação e conseqüente extensão do período de anestesia.Due to continuously improved technologies, the present generation of implantable cardioverter-defibrillators (ICD guarantees a high degree of safety and efficacy for detecting and terminating ventricular tachyarrhythmias. This paper summarizes the clinical results obtained with 1058 single-chamber ICD (Phylax 6, Phylax XM, Biotronik employing single-lead and active housing technology (SPS and Kainox RV (single coil, SL-ICD and Kainox SL (double coil, Biotronik. In all but 3 patients (> 99%, reliable low-energy defibrillation was achieved using transvenous leads only. This has led to the trend to replace DFT testing by a short function test during implantation in order to minimize the risks associated with repeated induction of fibrillation and extended anesthesia.

  11. Bystander Defibrillation for Out-of-Hospital Cardiac Arrest in Public vs Residential Locations

    DEFF Research Database (Denmark)

    Hansen, Steen Møller; Hansen, Carolina Malta; Folke, Fredrik

    2017-01-01

    Importance: Bystander-delivered defibrillation (hereinafter referred to as bystander defibrillation) of patients with out-of-hospital cardiac arrests (OHCAs) remains limited despite the widespread dissemination of automated external defibrillators (AEDs). Objective: To examine calendar changes...... in bystander defibrillation and subsequent survival according to a public or a residential location of the cardiac arrest after nationwide initiatives in Denmark to facilitate bystander-mediated resuscitative efforts, including bystander defibrillation. Design, Setting, and Participants: This nationwide study......, 2016. Exposures: Nationwide initiatives to facilitate bystander resuscitative efforts, including bystander defibrillation, consisted of resuscitation training of Danish citizens, dissemination of on-site AEDs, foundation of an AED registry linked to emergency medical dispatch centers, and dispatcher...

  12. Significant Association of Urinary Toxic Metals and Autism-Related Symptoms—A Nonlinear Statistical Analysis with Cross Validation

    Science.gov (United States)

    Adams, James; Kruger, Uwe; Geis, Elizabeth; Gehn, Eva; Fimbres, Valeria; Pollard, Elena; Mitchell, Jessica; Ingram, Julie; Hellmers, Robert; Quig, David; Hahn, Juergen

    2017-01-01

    Introduction A number of previous studies examined a possible association of toxic metals and autism, and over half of those studies suggest that toxic metal levels are different in individuals with Autism Spectrum Disorders (ASD). Additionally, several studies found that those levels correlate with the severity of ASD. Methods In order to further investigate these points, this paper performs the most detailed statistical analysis to date of a data set in this field. First morning urine samples were collected from 67 children and adults with ASD and 50 neurotypical controls of similar age and gender. The samples were analyzed to determine the levels of 10 urinary toxic metals (UTM). Autism-related symptoms were assessed with eleven behavioral measures. Statistical analysis was used to distinguish participants on the ASD spectrum and neurotypical participants based upon the UTM data alone. The analysis also included examining the association of autism severity with toxic metal excretion data using linear and nonlinear analysis. “Leave-one-out” cross-validation was used to ensure statistical independence of results. Results and Discussion Average excretion levels of several toxic metals (lead, tin, thallium, antimony) were significantly higher in the ASD group. However, ASD classification using univariate statistics proved difficult due to large variability, but nonlinear multivariate statistical analysis significantly improved ASD classification with Type I/II errors of 15% and 18%, respectively. These results clearly indicate that the urinary toxic metal excretion profiles of participants in the ASD group were significantly different from those of the neurotypical participants. Similarly, nonlinear methods determined a significantly stronger association between the behavioral measures and toxic metal excretion. The association was strongest for the Aberrant Behavior Checklist (including subscales on Irritability, Stereotypy, Hyperactivity, and Inappropriate

  13. Significant Association of Urinary Toxic Metals and Autism-Related Symptoms-A Nonlinear Statistical Analysis with Cross Validation.

    Science.gov (United States)

    Adams, James; Howsmon, Daniel P; Kruger, Uwe; Geis, Elizabeth; Gehn, Eva; Fimbres, Valeria; Pollard, Elena; Mitchell, Jessica; Ingram, Julie; Hellmers, Robert; Quig, David; Hahn, Juergen

    2017-01-01

    A number of previous studies examined a possible association of toxic metals and autism, and over half of those studies suggest that toxic metal levels are different in individuals with Autism Spectrum Disorders (ASD). Additionally, several studies found that those levels correlate with the severity of ASD. In order to further investigate these points, this paper performs the most detailed statistical analysis to date of a data set in this field. First morning urine samples were collected from 67 children and adults with ASD and 50 neurotypical controls of similar age and gender. The samples were analyzed to determine the levels of 10 urinary toxic metals (UTM). Autism-related symptoms were assessed with eleven behavioral measures. Statistical analysis was used to distinguish participants on the ASD spectrum and neurotypical participants based upon the UTM data alone. The analysis also included examining the association of autism severity with toxic metal excretion data using linear and nonlinear analysis. "Leave-one-out" cross-validation was used to ensure statistical independence of results. Average excretion levels of several toxic metals (lead, tin, thallium, antimony) were significantly higher in the ASD group. However, ASD classification using univariate statistics proved difficult due to large variability, but nonlinear multivariate statistical analysis significantly improved ASD classification with Type I/II errors of 15% and 18%, respectively. These results clearly indicate that the urinary toxic metal excretion profiles of participants in the ASD group were significantly different from those of the neurotypical participants. Similarly, nonlinear methods determined a significantly stronger association between the behavioral measures and toxic metal excretion. The association was strongest for the Aberrant Behavior Checklist (including subscales on Irritability, Stereotypy, Hyperactivity, and Inappropriate Speech), but significant associations were found

  14. In situ simulation comparing in-hospital first responder sudden cardiac arrest resuscitation using semiautomated defibrillators and automated external defibrillators.

    Science.gov (United States)

    Kobayashi, Leo; Dunbar-Viveiros, Jennifer A; Sheahan, Bethany A; Rezendes, Megan H; Devine, Jeffrey; Cooper, Mary R; Martin, Peggy B; Jay, Gregory D

    2010-04-01

    Multifaceted approaches using simulation and human factors methods may optimize in-hospital sudden cardiac arrest (SCA) response. The Arrhythmia Simulation/Cardiac Event Nursing Training-Automated External Defibrillator phase (ASCENT-AED) study used in situ medical simulation to compare traditional and AED-supplemented SCA first-responder models. The study was conducted at an academic 719-bed hospital with institutional review board approval. Two simulation scenarios were developed and featured either respiratory arrest with perfusing bradycardia or ventricular fibrillation (VF) arrest. Study floors were equipped with either a semiautomated defibrillator (SD) only (control) or with both SD and AED (experimental); subjects functioned as solitary first responders and did not receive resuscitation training. Fifty nurses were enrolled on control (n=25) and experimental (n=25) floors. The groups' nonblinded performances exhibited the following differences during VF scenario: slower calls for help by the control group [mean time to completion of 25+/-17 seconds versus 18+/-11 seconds for the experimental group (P<0.05)] and fewer subjects in the control group performing chest compressions [44.0% versus experimental group's 95.8% (P<0.001)]. Eighty-eight percent of the control group defibrillated the manikin at an average of 155+/-59 seconds, with 32.0% of those subjects using semiautomated rhythm analysis; 100% (not significant [NS]) of experimental group defibrillated at 154+/-72 seconds (NS) with 100% AED analysis (P<0.001). Fewer control group subjects (28.0%) were observed during the bradycardia scenarios to perform inappropriate chest compressions than the AED-supplemented subjects [69.6% (P=0.01)]; nonindicated defibrillation was delivered during these scenarios by a single subject in the control group. Twenty-eight percent and 72% of VF scenarios were managed appropriately by control and experimental groups, respectively; bradycardia scenarios were managed without

  15. [Uterine defibrillation in uterine inertia. Report of 2 cases].

    Science.gov (United States)

    Viñals, F; Correa, G; Quiroz, V

    1993-01-01

    The uterine atony are the most common cause of postpartum hemorrhage. Manual compression and pharmacologic methods are usually used with a successful result. When pharmacologic methods fail to control hemorrhage from atony, surgical measures should be undertaken to arrest the bleeding before it becomes life-threatening. We presents the utilization of electrical uterine defibrillation in two cases with acute hemorrhage confirming the effectivity of the proceeding.

  16. Worldwide experience with a totally subcutaneous implantable defibrillator

    DEFF Research Database (Denmark)

    Lambiase, Pier D; Barr, Craig; Theuns, Dominic A M J

    2014-01-01

    AIMS: The totally subcutaneous implantable-defibrillator (S-ICD) is a new alternative to the conventional transvenous ICD system to minimize intravascular lead complications. There are limited data describing the long-term performance of the S-ICD. This paper presents the first large internationa...... event rates and inappropriate shock rates comparable with those reported for conventional ICDs. Clinical trial registration URL: http://www.clinicaltrials.gov. Unique identifier NCT01085435....

  17. The Cause and Mechanism of Cardiac Electrical Instability. Defibrillation Mechanism

    Directory of Open Access Journals (Sweden)

    Rustam G. Habchabov

    2012-06-01

    Full Text Available The reason for the ominous arrhythmias pathway, causing sudden somatic death from cardiovascular diseases is still not clear, cardiological examinations of this phenomenon are conducted throughout the world. Laceration of connective insulating tissue membrane of heart pathway with ectopic nodes oxidation may cause ominous arrhythmias; nobody has considered this cause as a cardiac electrical instability before. Defibrillator electric discharges cannot penetrate into myocardium due to the connective insulating tissue membrane, nobody has considered nervous system, transmitting electricity.

  18. The role of automated external defibrillators in dental practice.

    Science.gov (United States)

    Boyd, Barry C; Fantuzzo, Joseph J; Votta, Timothy

    2006-01-01

    Dental practices are seeing an increasing number of elderly and medically compromised patients, making it likely that staff will be called upon to respond to medical emergencies in the office, including cardiac arrest. Out-of-hospital cardiac arrests account for nearly half of all cardiovascular deaths in the United States. In adult cardiac arrest victims, the most frequent cause of sudden cardiac arrest is ventricular dysrhythmia, either ventricular tachycardia or ventricular fibrillation. The survival rate for sufferers of out-of-hospital cardiac arrests is a dismal 1% to 5% to hospital discharge. A majority of people who survive to discharge sustain significant morbidity. Untreated ventricular fibrillation degenerates into asystole, which is often refractory to resuscitative efforts and represents a terminal event. The development and availability of the automated external defibrillator (AED) represents a promising advance in the pre-hospital early defibrillation of victims of sudden cardiac arrest in a variety of settings, often remote from hospitals or EMS personnel. Given the medically compromised segment of the population treated in many dental practices today, it is imperative that dental practitioners and allied health providers become trained in the recognition and prompt initiation of emergency care, including basic life support with early defibrillation. The AED is becoming more accessible, with increasingly widespread availability, training in its use and relative ease of operation, making the goal of increased survival one in which dental health professionals can play a part.

  19. Estimation of current density distribution under electrodes for external defibrillation

    Directory of Open Access Journals (Sweden)

    Papazov Sava P

    2002-12-01

    Full Text Available Abstract Background Transthoracic defibrillation is the most common life-saving technique for the restoration of the heart rhythm of cardiac arrest victims. The procedure requires adequate application of large electrodes on the patient chest, to ensure low-resistance electrical contact. The current density distribution under the electrodes is non-uniform, leading to muscle contraction and pain, or risks of burning. The recent introduction of automatic external defibrillators and even wearable defibrillators, presents new demanding requirements for the structure of electrodes. Method and Results Using the pseudo-elliptic differential equation of Laplace type with appropriate boundary conditions and applying finite element method modeling, electrodes of various shapes and structure were studied. The non-uniformity of the current density distribution was shown to be moderately improved by adding a low resistivity layer between the metal and tissue and by a ring around the electrode perimeter. The inclusion of openings in long-term wearable electrodes additionally disturbs the current density profile. However, a number of small-size perforations may result in acceptable current density distribution. Conclusion The current density distribution non-uniformity of circular electrodes is about 30% less than that of square-shaped electrodes. The use of an interface layer of intermediate resistivity, comparable to that of the underlying tissues, and a high-resistivity perimeter ring, can further improve the distribution. The inclusion of skin aeration openings disturbs the current paths, but an appropriate selection of number and size provides a reasonable compromise.

  20. Percutaneous Extraction of Transvenous Permanent Pacemaker/Defibrillator Leads

    Directory of Open Access Journals (Sweden)

    Stylianos Paraskevaidis

    2014-01-01

    Full Text Available Background. Widespread use of cardiovascular implantable electronic devices has inevitably increased the need for lead revision/replacement. We report our experience in percutaneous extraction of transvenous permanent pacemaker/defibrillator leads. Methods. Thirty-six patients admitted to our centre from September 2005 through October 2012 for percutaneous lead extraction were included. Lead removal was attempted using Spectranetics traction-type system (Spectranetics Corp., Colorado, CO, USA and VascoExtor countertraction-type system (Vascomed GmbH, Weil am Rhein, Germany. Results. Lead extraction was attempted in 59 leads from 36 patients (27 men, mean ± SD age 61±5 years, with permanent pacemaker (n=25, defibrillator (n=8, or cardiac resynchronisation therapy (n=3 with a mean ± SD implant duration of 50±23 months. The indications for lead removal included pocket infection (n=23, endocarditis (n=2, and ventricular (n=10 and atrial lead dysfunction (n=1. Traction device was used for 33 leads and countertraction device for 26 leads. Mean ± SD fluoroscopy time was 4±2 minutes/lead for leads implanted 48 months (n=21, P=0.03. Complete procedural success rate was 91.7% and clinical procedural success rate was 100%, while lead procedural success rate was 95%. Conclusions. In conclusion, percutaneous extraction of transvenous permanent pacemaker/defibrillator leads using dedicated removal tools is both feasible and safe.

  1. Clinical management of electromagnetic interferences in patients with pacemakers and implantable cardioverter-defibrillators: review of the literature and focus on magnetic resonance conditional devices.

    Science.gov (United States)

    Corzani, Alessandro; Ziacchi, Matteo; Biffi, Mauro; Allaria, Luca; Diemberger, Igor; Martignani, Cristian; Bratten, Tara; Gardini, Beatrice; Boriani, Giuseppe

    2015-10-01

    The number of cardiac implantable electronic devices (CIEDs) has greatly increased in the last 10 years. Many electronic devices used in daily activities generate electromagnetic interferences (EMIs) that can interact with CIEDs. In clinical practice, it is very important to know the potential sources of EMIs and their effect on CIEDs in order to understand how to manage or mitigate them. A very important source of EMI is magnetic resonance (MR), which is considered nowadays the diagnostic gold standard for different anatomical districts. In this review, we focused on the effects of EMI on CIEDs and on the clinical management. Moreover, we made a clarification about MR and CIEDs.In patients with CIEDs, EMIs may cause potentially serious and even life-threatening complications (inappropriate shocks, device malfunctions, inhibition of pacing in pacemaker-dependent patients) and may rarely dictate device replacement. The association of inappropriate shocks with increased mortality highlights the importance of minimizing the occurrence of EMI. Adequate advice and recommendations about the correct management of EMIs in patients with CIEDs are required to avoid all complications during hospitalization and in daily life. Furthermore, the article focused on actual management about MR and CIEDs.

  2. Physical Activity in Primary Versus Secondary Prevention Indication Implantable Cardioverter Defibrillator Recipients 6–12 Months After Implantation – A Cross-Sectional Study With Register Follow Up

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Thygesen, Lau Caspar; Svendsen, Jesper Hastrup

    2015-01-01

    outcomes; to describe patients' beliefs regarding participation in physical exercise by ICD indication; to describe factors predicting low physical activity; and to describe physical activity as a predictor of mortality. DESIGN: National survey with register follow-up. Comparisons were made to a matched......, with 82% of participants being men. Of the participants, 37% participated in a rehabilitation program, and 21% were sedentary compared with 8% in the reference population (Pphysical exercise guidelines. Low physical activity was predicted by primary prevention...... indication (odds ratio [OR]=2.5; 95% confidence interval [CI], 1.3-4.7) and higher comorbidity (OR=2.1; 95% CI, 1.0-4.1; Pphysical activity was associated with increased mortality (OR=3.9; 95% CI, 1.11-13.71; Psex...

  3. The CopenHeartSF trial—comprehensive sexual rehabilitation programme for male patients with implantable cardioverter defibrillator or ischaemic heart disease and impaired sexual function

    DEFF Research Database (Denmark)

    Johansen, Pernille Palm; Zwisler, Ann-Dorthe; Svendsen, Jesper Hastrup

    2013-01-01

    Sexuality is an important part of people's physical and mental health. Patients with heart disease often suffer from sexual dysfunction. Sexual dysfunction has a negative impact on quality of life and well-being in persons with heart disease, and sexual dysfunction is associated with anxiety...... and depression. Treatment and care possibilities seem to be lacking. Studies indicate that non-pharmacological interventions such as exercise training and psychoeducation possess the potential of reducing sexual dysfunction in patients with heart disease. The CopenHeartSF trial will investigate the effect...... of a comprehensive sexual rehabilitation programme versus usual care....

  4. Potential demographic and baselines variables for risk stratification of high-risk post-myocardial infarction patients in the era of implantable cardioverter-defibrillator - a prognostic indicator

    DEFF Research Database (Denmark)

    Yap, Yee Guan; Duong, Trinh; Bland, Martin

    2008-01-01

    , sex, previous MI or angina, hypertension, diabetes, systolic blood pressure, heart rate, NYHA functional class and non-Q wave infarct on electrocardiogram. Distinct survival curves were obtained for 3 risk groups based on the median and inter-quartile range for the prognostic index. In the high-risk......BACKGROUND: Risk stratification after myocardial infarction (MI) remains expensive and disappointing. We designed a prognostic indicator using demographic information to select patients at risk of dying after MI. METHOD AND RESULTS: We combined individual patient data from the placebo arms of EMIAT......, CAMIAT, TRACE and DIAMOND-MI with LVEF 10 ventricular premature beats/hour or a run of ventricular tachycardia). Risk factors for mortality beginning at day 45 post-MI up to 2 years were examined using Cox regression analysis. Risk scores were derived from the equation of a Cox regression model...

  5. Is modification of the VVI backup mode in implantable cardioverter-defibrillators from St Jude medical required due to increased risk of inappropriate shocks?

    DEFF Research Database (Denmark)

    Philbert, Berit T; Tfelt-Hansen, Jacob; Jacobsen, Peter K

    2017-01-01

    a ventricular fibrillation (VF) zone starting at 146 b.p.m., with shock therapy only and changes in sensitivity settings making the ICD more sensitive. In all cases, the reason for the multiple inappropriate shocks was that the VF zone was reached due to exercise-induced sinus tachycardia or due to oversensing...

  6. Acompanhamento clínico de pacientes portadores de cardioversor-desfibrilador implantável Clinical follow-up of patients with implantable cardioverter-defibrillator

    Directory of Open Access Journals (Sweden)

    Silvia Martelo Souza da Fonseca

    2007-01-01

    Full Text Available OBJETIVO: Relatar o perfil de terapias apropriadas (TA e inapropriadas (TI do cardioversores-desfibriladores implantáveis (CDI em portadores de cardiopatia isquêmica e não-isquêmica e as complicações precoces e tardias do procedimento. MÉTODOS: Foram analisados 155 pacientes (119 homens e 36 mulheres, idade média de 47 (21-88 anos, submetidos ao implante de CDI. Foram divididos em grupos I - pacientes pós-infarto agudo do miocárdio (IAM (n = 80, grupo II - cardiopatia não-isquêmica e fração de ejeção de ventrículo esquerdo (FEVE OBJECTIVE: To report appropriate (AT and inappropriate (IT ICD therapies in patients with ischemic and nonischemic heart disease, as well as early and late procedure-related complications. METHODS: One hundred and fifty-five patients (119 male and 36 female, mean age 47 years (21-88, who underwent ICD implantation between 1994 and March 2003 were analyzed. Patients were divided into the following groups: Group I - Post-AMI patients (n = 80; Group II - Patients with nonischemic heart disease and LV ejection fraction < 40% (n = 45, Chagas disease (n = 18, idiopathic dilated cardiomyopathy (n= 12, hypertensive disease (n = 8, hypertrophic cardiomyopathy (n = 4 and valvular heart disease (n = 3; Group III - Patients with arrhythmogenic right ventricular dysplasia (n = 13; and Group IV - Patients with channelopathies: Brugada Syndrome (n = 8 and idiopathic ventricular arrhythmias (n = 9. All patients underwent electrophysiological study (EPS with induction of sustained ventricular arrhythmia ICD implantation. RESULTS: During the 26-month mean follow up, a high rate of appropriate ICD therapies (antitachycardia pacing and/or shock was observed (46% in the four groups, with no statistically significant difference. The four groups did not differ in either overall (8.4% or arrhythmic mortality (1.3%. There was no correlation between appropriate ICD therapies and initial clinical presentation or inducible ventricular arrhythmia at EPS, and a 4% incidence of early and late procedure-related complications was found. CONCLUSION: The high incidence of appropriate ICD therapy and low rate of sudden death in the patients studied suggest that ICD is a valuable strategy in the management of ischemic and nonischemic patients previously selected by means of EPS.

  7. Rasch Validation and Cross-validation of the Health of Nation Outcome Scales (HoNOS) for Monitoring of Psychiatric Disability in Traumatized Refugees in Western Psychiatric Care

    DEFF Research Database (Denmark)

    Palic, Sabina; Kappel, Michelle Lind; Makransky, Guido

    2016-01-01

    Rasch analysis we evaluated the psychometrics of the Health of Nation Outcome Scales (HoNOS) in pre-treatment data of consecutive refugee patients (N = 448) from a Danish psychiatric clinic. Then, we carried out a cross-validation of the pre-treatment HoNOS model on post-treatment data from the same...... group. A revised 10-item HoNOS fit the Rasch model at pre-treatment, and also showed excellent fit within the cross-validation data. Culture, gender, and need for translation did not exert serious bias on the measure’s performance. The results establish good monitoring properties of the 10-item Ho...

  8. Additional coronary sinus shocking lead as rescue therapy after multiple internal and external defibrillation failures.

    Science.gov (United States)

    Chauveau, Samuel; Dulac, Arnaud; Sebbag, Laurent; Morel, Elodie; Chevalier, Philippe

    2017-06-01

    High defibrillation threshold (DFT) and defibrillation failure can lead to intractable ventricular arrhythmias. Additional coronary sinus coil is an effective strategy to achieve marked reduction in DFT. However, physicians should retain this might prevent future coronary sinus lead placement in case the patient would develop complete left bundle branch block.

  9. [First responder defibrillation in the USA, Europe and Germany--prerequisites, experiences, perspectives].

    Science.gov (United States)

    Trappe, H-J

    2005-06-01

    Sudden out-of-hospital cardiac arrest is a leading cause of death and only 5-8% of patients survive such event. Defibrillation is the mose effective treatment and should performed within 5 minutes; however, its effectiveness diminishes with each passing minute. "Early defibrillation" is the use of automated external defibrillators (AEDs) by trained public-safety personnal ("first responder"), whereas "public access" defibrillation describes AED use by persons who have no specific AED training. Several studies in the US and in Europe show that first responder defibrillation will increase the number of survivors of out-of-hospital cardiac arrest compared to paramedics. This is caused by a shorter "call-to-arrival-time" in first responders compared to paramedics. In Europe, programs for the use of automated external defibrillators exist only occasionally. Reasons for this are the lack of open-mindedness, logistic and legal problems. In Germany, there are only few AED programs with promising results. At the present time, placement of automated external defibrillators in public places frequented by a large number of susceptible people will increase overall survival. However, placement of AEDs in all public places is still debatable and further studies are necessary to estimate the potential impact of publicc access defibrillators.

  10. Crossing the North Sea seems to make DCD disappear: cross-validation of Movement Assessment Battery for Children-2 norms.

    Science.gov (United States)

    Niemeijer, Anuschka S; van Waelvelde, Hilde; Smits-Engelsman, Bouwien C M

    2015-02-01

    The Movement Assessment Battery for Children has been revised as the Movement ABC-2 (Henderson, Sugden, & Barnett, 2007). In Europe, the 15th percentile score on this test is recommended for one of the DSM-IV diagnostic criteria for Developmental Coordination Disorder (DCD). A representative sample of Dutch and Flemish children was tested to cross-validate the UK standard scores, including the 15th percentile score. First, the mean, SD and percentile scores of Dutch children were compared to those of UK normative samples. Item standard scores of Dutch speaking children deviated from the UK reference values suggesting necessary adjustments. Except for very young children, the Dutch-speaking samples performed better. Second, based on the mean and SD and clinical relevant cut-off scores (5th and 15th percentile), norms were adjusted for the Dutch population. For diagnostic use, researchers and clinicians should use the reference norms that are valid for the group of children they are testing. The results indicate that there possibly is an effect of testing procedure in other countries that validated the UK norms and/or cultural influence on the age norms of the Movement ABC-2. It is suggested to formulate criterion-based norms for age groups in addition to statistical norms.

  11. Cross-validation of generalised body composition equations with diverse young men and women: the Training Intervention and Genetics of Exercise Response (TIGER) Study

    Science.gov (United States)

    Generalised skinfold equations developed in the 1970s are commonly used to estimate laboratory-measured percentage fat (BF%). The equations were developed on predominately white individuals using Siri's two-component percentage fat equation (BF%-GEN). We cross-validated the Jackson-Pollock (JP) gene...

  12. Screening for posttraumatic stress disorder in civilian substance use disorder patients: Cross-validation of the Jellinek-PTSD screening questionnaire

    NARCIS (Netherlands)

    van Dam, D.; Ehring, T.; Vedel, E.; Emmelkamp, P.M.G.

    2013-01-01

    This study aimed to cross-validate earlier findings regarding the diagnostic efficiency of a modified version of the Primary Care Posttraumatic Stress Disorder (PC-PTSD) screening questionnaire (A. Prins, P. Ouimette, R. Kimerling, R. P. Cameron, D. S. Hugelshofer, J. Shaw-Hegwer, et al., 2004). The

  13. Cross-Validation of a Recently Published Equation Predicting Energy Expenditure to Run or Walk a Mile in Normal-Weight and Overweight Adults

    Science.gov (United States)

    Morris, Cody E.; Owens, Scott G.; Waddell, Dwight E.; Bass, Martha A.; Bentley, John P.; Loftin, Mark

    2014-01-01

    An equation published by Loftin, Waddell, Robinson, and Owens (2010) was cross-validated using ten normal-weight walkers, ten overweight walkers, and ten distance runners. Energy expenditure was measured at preferred walking (normal-weight walker and overweight walkers) or running pace (distance runners) for 5 min and corrected to a mile. Energy…

  14. High-dose lidocaine does not affect defibrillation efficacy: implications for defibrillation mechanisms.

    Science.gov (United States)

    Ujhelyi, M R; Sims, J J; Miller, A W

    1998-04-01

    This study assessed the effect of low (10 mg.kg-1.h-1) and very high (18 mg.kg-1.h-1) doses of lidocaine on defibrillation energy requirements (DER) to relate changes in indexes of sodium-channel blockade with changes in DER values using a dose-response study design. In group 1 (control; n = 6 pigs), DER values were determined at baseline and during treatment with 5% dextrose in water (D5W) and with D5W added to D5W. In group 2 (n = 7), DER values were determined at baseline and during treatment with low-dose lidocaine followed by high-dose lidocaine. In group 3 (n = 3), DER values were determined at baseline and high-dose lidocaine. Group 3 controlled for the order of lidocaine treatment with the addition of high-dose lidocaine after baseline. DER values in group 1 did not change during D5W. In group 2, low-dose lidocaine increased DER values by 51% (P = 0.01), whereas high-dose lidocaine added to low-dose lidocaine reduced DER values back to within 6% of baseline values (P = 0.02, low dose vs. high dose). DER values during high-dose lidocaine in group 3 also remained near baseline values (16.2 +/- 2.7 to 12.9 +/- 2.7 J), demonstrating that treatment order had no impact on group 2. Progressive sodium-channel blockade was evident as incremental reduction in ventricular conduction velocity as the lidocaine dose increased. Lidocaine also significantly increased ventricular fibrillation cycle length as the lidocaine dose increased. However, the greatest increase in DER occurred when ventricular fibrillation cycle length was minimally affected, demonstrating a negative correlation (P = 0.04). In summary, lidocaine has an inverted U-shaped DER dose-response curve. At very high lidocaine doses, DER values are similar to baseline and tend to decrease rather than increase. Increased refractoriness during ventricular fibrillation may be the electrophysiological mechanism by which high-dose lidocaine limits the adverse effects that low-dose lidocaine has on DER values

  15. Joint use of over- and under-sampling techniques and cross-validation for the development and assessment of prediction models.

    Science.gov (United States)

    Blagus, Rok; Lusa, Lara

    2015-11-04

    Prediction models are used in clinical research to develop rules that can be used to accurately predict the outcome of the patients based on some of their characteristics. They represent a valuable tool in the decision making process of clinicians and health policy makers, as they enable them to estimate the probability that patients have or will develop a disease, will respond to a treatment, or that their disease will recur. The interest devoted to prediction models in the biomedical community has been growing in the last few years. Often the data used to develop the prediction models are class-imbalanced as only few patients experience the event (and therefore belong to minority class). Prediction models developed using class-imbalanced data tend to achieve sub-optimal predictive accuracy in the minority class. This problem can be diminished by using sampling techniques aimed at balancing the class distribution. These techniques include under- and oversampling, where a fraction of the majority class samples are retained in the analysis or new samples from the minority class are generated. The correct assessment of how the prediction model is likely to perform on independent data is of crucial importance; in the absence of an independent data set, cross-validation is normally used. While the importance of correct cross-validation is well documented in the biomedical literature, the challenges posed by the joint use of sampling techniques and cross-validation have not been addressed. We show that care must be taken to ensure that cross-validation is performed correctly on sampled data, and that the risk of overestimating the predictive accuracy is greater when oversampling techniques are used. Examples based on the re-analysis of real datasets and simulation studies are provided. We identify some results from the biomedical literature where the incorrect cross-validation was performed, where we expect that the performance of oversampling techniques was heavily

  16. Long-term efficacy of implantable cardiac resynchronization therapy plus defibrillator for primary prevention of sudden cardiac death in patients with mild heart failure: an updated meta-analysis.

    Science.gov (United States)

    Sun, Wei-Ping; Li, Chun-Lei; Guo, Jin-Cheng; Zhang, Li-Xin; Liu, Ran; Zhang, Hai-Bin; Zhang, Ling

    2016-07-01

    Previous studies of implantable cardiac resynchronization therapy plus defibrillator (CRT-D) therapy used for primary prevention of sudden cardiac death have suggested that CRT-D therapy is less effective in patients with mild heart failure and a wide QRS complex. However, the long-term benefits are variable. We performed a meta-analysis of randomized trials identified in systematic searches of MEDLINE, EMBASE, and the Cochrane Database. Three studies (3858 patients) with a mean follow-up of 66 months were included. Overall, CRT-D therapy was associated with significantly lower all-cause mortality than was implantable cardioverter defibrillator (ICD) therapy (OR, 0.78; 95 % CI, 0.63-0.96; P = 0.02; I (2) = 19 %). However, the risk of cardiac mortality was comparable between two groups (OR, 0.74; 95 % CI, 0.53-1.01; P = 0.06). CRT-D treatment was associated with a significantly lower risk of hospitalization for heart failure (OR, 0.67; 95 % CI, 0.50-0.89; P = 0.005; I (2) = 55 %). The composite outcome of all-cause mortality and hospitalization for heart failure was also markedly lower with CRT-D therapy than with ICD treatment alone (OR, 0.67; 95 % CI, 0.57-0.77; P failure events in patients with mild heart failure with a wide QRS complex. However, long-term risk of cardiac mortality was similar between two groups. More randomized studies are needed to confirm these findings, especially in patients with NYHA class I heart failure or patients without LBBB.

  17. Bystander Defibrillation for Out-of-Hospital Cardiac Arrest in Public vs Residential Locations.

    Science.gov (United States)

    Hansen, Steen Møller; Hansen, Carolina Malta; Folke, Fredrik; Rajan, Shahzleen; Kragholm, Kristian; Ejlskov, Linda; Gislason, Gunnar; Køber, Lars; Gerds, Thomas A; Hjortshøj, Søren; Lippert, Freddy; Torp-Pedersen, Christian; Wissenberg, Mads

    2017-05-01

    Bystander-delivered defibrillation (hereinafter referred to as bystander defibrillation) of patients with out-of-hospital cardiac arrests (OHCAs) remains limited despite the widespread dissemination of automated external defibrillators (AEDs). To examine calendar changes in bystander defibrillation and subsequent survival according to a public or a residential location of the cardiac arrest after nationwide initiatives in Denmark to facilitate bystander-mediated resuscitative efforts, including bystander defibrillation. This nationwide study identified 18 688 patients in Denmark with first-time OHCA from June 1, 2001, to December 31, 2012, using the Danish Cardiac Arrest Registry. Patients had a presumed cardiac cause of arrest that was not witnessed by emergency medical services personnel. Data were analyzed from April 1, 2015, to December 10, 2016. Nationwide initiatives to facilitate bystander resuscitative efforts, including bystander defibrillation, consisted of resuscitation training of Danish citizens, dissemination of on-site AEDs, foundation of an AED registry linked to emergency medical dispatch centers, and dispatcher-assisted guidance of bystander resuscitation efforts. The proportion of patients who received bystander defibrillation according to the location of the cardiac arrest and their subsequent 30-day survival. Of the 18 688 patients with OHCAs (67.8% men and 32.2% women; median [interquartile range] age, 72 [62-80] years), 4783 (25.6%) had a cardiac arrest in a public location and 13 905 (74.4%) in a residential location. The number of registered AEDs increased from 141 in 2007 to 7800 in 2012. The distribution of AED location was consistently skewed in favor of public locations. Bystander defibrillation increased in public locations from 3 of 245 (1.2%; 95% CI, 0.4%-3.5%) in 2001 to 78 of 510 (15.3%; 95% CI, 12.4%-18.7%) in 2012 (P bystander defibrillation increased in public locations from 8.3% (95% CI, 1.5%-35.4%) in 2001/2002 to 57

  18. Contact dermatitis after implantable cardiac defibrillator implantation for ventricular tachycardia.

    Science.gov (United States)

    Dogan, Pinar; Inci, Sinan; Kuyumcu, Mevlut Serdar; Kus, Ozgur

    2016-02-01

    Pacemaker contact sensitivity is a rare condition. Less than 30 reports of pacemaker skin reactions have been described. We report a 57-year-old woman who underwent an implantable cardiac defibrillator (ICD) implantation for ventricular tachycardia. A skin patch test was positive on almost all components of the pacemaker system. She was treated with topical corticosteroids and skin lesions resolved within 2 weeks. Because of widespread use of various devices, we will see this more often and therefore it is important to recognize this problem and its effective management.

  19. Accuracy of Genome-Enabled Prediction in a Dairy Cattle Population using Different Cross-Validation Layouts

    Science.gov (United States)

    Pérez-Cabal, M. Angeles; Vazquez, Ana I.; Gianola, Daniel; Rosa, Guilherme J. M.; Weigel, Kent A.

    2012-01-01

    The impact of extent of genetic relatedness on accuracy of genome-enabled predictions was assessed using a dairy cattle population and alternative cross-validation (CV) strategies were compared. The CV layouts consisted of training and testing sets obtained from either random allocation of individuals (RAN) or from a kernel-based clustering of individuals using the additive relationship matrix, to obtain two subsets that were as unrelated as possible (UNREL), as well as a layout based on stratification by generation (GEN). The UNREL layout decreased the average genetic relationships between training and testing animals but produced similar accuracies to the RAN design, which were about 15% higher than in the GEN setting. Results indicate that the CV structure can have an important effect on the accuracy of whole-genome predictions. However, the connection between average genetic relationships across training and testing sets and the estimated predictive ability is not straightforward, and may depend also on the kind of relatedness that exists between the two subsets and on the heritability of the trait. For high heritability traits, close relatives such as parents and full-sibs make the greatest contributions to accuracy, which can be compensated by half-sibs or grandsires in the case of lack of close relatives. However, for the low heritability traits the inclusion of close relatives is crucial and including more relatives of various types in the training set tends to lead to greater accuracy. In practice, CV designs should resemble the intended use of the predictive models, e.g., within or between family predictions, or within or across generation predictions, such that estimation of predictive ability is consistent with the actual application to be considered. PMID:22403583

  20. Automated external defibrillators in the Australian fitness industry.

    Science.gov (United States)

    Norton, Kevin I; Norton, Lynda H

    2008-04-01

    Sudden cardiac arrest (SCA) occurs in many thousands of Australians each year. Scientific evidence shows an increased survival rate for individuals who receive electrical defibrillation in the first few minutes after SCA. In the last decade automated (rhythm-detecting) external defibrillators (AEDs) have become available that are portable and affordable. Although still relatively rare, there is still the potential that SCA may occur when a person undertakes physical activity. Consequently, health/fitness centres are increasingly recognised as higher risk sites that may benefit from placement of AEDs. There are no laws in Australia requiring health/fitness centres to install AEDs. However, several international and professional organisations have "strongly encouraged" larger centres to install AEDs. Guidelines and algorithms are presented to help estimate the risk of SCA in fitness centres. Fitness centre placement is particularly important if the clientele is older or has a 'high-risk' profile, for example, clients with cardiovascular, respiratory or metabolic disease. International negligence case law and duty of care principles suggests the standard of care required in health/fitness centres may be increasing. Therefore, it may be prudent to install AEDs in larger centres and those in which higher risk groups are physically active.

  1. Defibrillation beliefs of rural nurses: focus group discussions guided by the Theory of Planned Behaviour.

    Science.gov (United States)

    Dwyer, T A; Mosel Williams, L; Mummery, K

    2005-01-01

    The endorsement of the chain of survival concept and early defibrillation has challenged health professionals to reconsider their beliefs about how they respond to in-hospital resuscitation. In the rural context, where 24 hour coverage is not available nurse-initiated defibrillation is expected. Despite literature and policy change in Australia to allow nurses to initiate defibrillation, there is no current research that uses a systemic theoretical approach to investigate the specific beliefs of nurses and their use of defibrillators. The purpose of this study was to elicit a beginning understanding of the defibrillation beliefs of rural nurses. This research used focus groups within the framework of the Theory of Planned Behavior to describe the defibrillation beliefs of rural registered nurses. The sites selected for this study were two acute care hospitals in rural Australia (RRMA Classification). Each of these hospitals was in located 'other rural areas' (RRMA Classification) in separate towns and had 25 and 30 beds. The study sample consisted of 10 females and two males. Focus group questions were designed to elicit salient beliefs within the theoretical framework. Three constructs of behavioral, normative and control beliefs guided the development of the question and analysis of the discussions. In accordance with the authors of the theoretical framework, content analysis was used to analyse the data from the study. Two behavioral beliefs, four control beliefs and four normative belief categories were elicited. Two behavioral beliefs categories emerged from the open-ended question: 'What, if any are the advantages of you being able to use a defibrillator?' Participants were congruent when discussing the advantages of nurses initiating defibrillation. The two categories were 'quicker response times' (15 responses) and 'increased success with resuscitation' (8 responses). Participants were asked to identify any events that might influence their decision to use

  2. Influence of left ventricular function on survival and mode of death after implantable defibrillator therapy (Cleveland Clinic Foundation and Montefiore Medical Center experience).

    Science.gov (United States)

    Kim, S G; Maloney, J D; Pinski, S L; Choue, C W; Ferrick, K J; Roth, J A; Gross, J; Brodman, R; Furman, S; Fisher, J D

    1993-12-01

    To determine the influence of left ventricular (LV) function on survival and mode of death in patients with an implantable cardioverter-defibrillator (ICD), sudden death, surgical mortality, total arrhythmia-related death, total cardiac death and total death were retrospectively evaluated in 377 consecutive patients. The outcomes were also compared between patients with an LV ejection fraction > or = 30% (214 patients, group 1) and < 30% (148 patients, group 2). Surgical mortality was 3.9% (1.8% in group 1, 7% in group 2). During the follow-up of 25 +/- 20 months, actuarial survival rates of all patients at 3 years were 96% for sudden deaths, 81% for total cardiac deaths and 74% for total mortality. When the 2 groups were compared, survival rates of groups 1 and 2 at 3 years, respectively, were 99 and 90% for sudden death (p < 0.05), 97 and 84% for sudden death and surgical mortality (p < 0.01), 94 and 80% for the total arrhythmia-related death (p < 0.001), 88 and 68% for total cardiac death (p < 0.0001), and 81 and 62% for total mortality (p < 0.002). In group 2, 73% of total cardiac deaths within 1 year were causally related to the arrhythmia. Thus, in patients with an ICD, sudden death rates were very low. However, total cardiac death and total death rates were relatively higher. The outcomes of patients with an ICD were strongly influenced by the degree of LV dysfunction.(ABSTRACT TRUNCATED AT 250 WORDS)

  3. Very high rate programming in primary prevention patients with reduced ejection fraction implanted with a defibrillator: Results from a large multicenter controlled study.

    Science.gov (United States)

    Clementy, Nicolas; Challal, Farid; Marijon, Eloi; Boveda, Serge; Defaye, Pascal; Leclercq, Christophe; Deharo, Jean-Claude; Sadoul, Nicolas; Klug, Didier; Piot, Olivier; Gras, Daniel; Bordachar, Pierre; Algalarrondo, Vincent; Fauchier, Laurent; Babuty, Dominique

    2017-02-01

    Programming implantable cardioverter-defibrillators (ICDs) with a high-rate therapy strategy has proven to be effective in reducing shocks and is associated with a reduced mortality. We sought to determine the impact of a very high rate cutoff programming strategy on outcomes in patients with a primary indication for an ICD due to reduced left ventricular ejection fraction. Using data from the multicenter French DAI-PP registry, this cohort-controlled study compared outcomes in 500 patients programmed with a very high rate cutoff (VH-RATE group: monitor zone 170-219 beats/min; ventricular fibrillation zone ≥220 beats/min with 13 ± 4 detection intervals) with 1500 matched control patients programmed with 1 or 2 therapy zone. All ICDs were implanted for primary prevention in patients with systolic dysfunction. Risks of events were compared after propensity score matching of sex, age, ejection fraction, New York Heart Association class, cardiomyopathy, atrial fibrillation, and type of device. After a mean follow-up of 3.6 ± 2.3 years, VH-RATE programming was associated with a reduction of appropriate therapy risk (hazard ratio [HR] 0.40; 95% confidence interval [CI] 0.31-0.51; P programmed with 2 therapy zones. There was no significant difference in overall survival between the groups. In patients implanted with an ICD in primary prevention with left ventricular dysfunction, very high rate cutoff programming (single therapy zone ≥220 beats/min) was associated with a 60% reduction of appropriate therapies as well as inappropriate shocks, without affecting mortality. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  4. Influence of time between last myocardial infarction and prophylactic implantable defibrillator implant on device detections and therapies. “Routine Practice” data from the SEARCH MI registry

    Directory of Open Access Journals (Sweden)

    Boriani Giuseppe

    2012-09-01

    Full Text Available Abstract Background A multicenter European Registry, SEARCH-MI, was instituted in the year 2002 in order to assess patients’ outcomes and ICD interventions in patients with a previous MI and depressed LV function, treated with an ICD according to MADIT II results. In this analysis, we evaluate the influence of the time elapsed between last myocardial infarction (MI and prophylactic cardioverter defibrillator (ICD implant on device activations. Methods 643 patients with left ventricular dysfunction (mean LVEF 26 ± 5% and NYHA class I-III were prospectively followed for 1.8 ± 1.2 years in a multicenter registry. The population was divided into 3 groups according to the time between last MI and ICD implant: [1] from 40 days to less than 1.5 years; [2] from 1.5 to less than 7 years and [3] at least 7 years. Results The cumulative incidence of ventricular tachyarrhymias and appropriate device therapy (ATP or shock were higher in patients implanted longer time from last MI (Gray’s Test p = 0.002 and p = 0.013 respectively. No significant differences were seen in all cause mortality (Gray’s Test p = 0.618 or sudden cardiac death across the MI stratification groups (Gray’s Test p = 0.663. Conclusions Patients implanted with an ICD longer after the MI have a higher chance of presenting ventricular tachyarrhythmias and appropriate ICD therapy, while no differences were seen in overall mortality. These observations may be important for improving patient targeting in sudden death prevention.

  5. The Effect of Compressor-Administered Defibrillation on Peri-shock Pauses in a Simulated Cardiac Arrest Scenario

    Directory of Open Access Journals (Sweden)

    Joshua Glick

    2014-03-01

    Full Text Available Introduction: Coordination of the tasks of performing chest compressions and defibrillation can lead to communication challenges that may prolong time spent off the chest. The purpose of this study was to determine whether defibrillation provided by the provider performing chest compressions led to a decrease in peri-shock pauses as compared to defibrillation administered by a second provider, in a simulated cardiac arrest scenario. Methods: This was a randomized, controlled study measuring pauses in chest compressions for defibrillation in a simulated cardiac arrest model. We approached hospital providers with current CPR certification for participation between July, 2011 and October, 2011. Volunteers were randomized to control (facilitator-administered defibrillation or experimental (compressor-administered defibrillation groups. All participants completed one minute of chest compressions on a mannequin in a shockable rhythm prior to administration of defibrillation. We measured and compared pauses for defibrillation in both groups. Results: Out of 200 total participants, we analyzed data from 197 defibrillations. Compressor-initiated defibrillation resulted in a significantly lower pre-shock hands-off time (0.57 s; 95% CI: 0.47-0.67 compared to facilitator-initiated defibrillation (1.49 s; 95% CI: 1.35-1.64. Furthermore, compressor-initiated defibrillation resulted in a significantly lower peri-shock hands-off time (2.77 s; 95% CI: 2.58-2.95 compared to facilitator-initiated defibrillation (4.25 s; 95% CI: 4.08-4.43. Conclusion: Assigning the responsibility for shock delivery to the provider performing compressions encourages continuous compressions throughout the charging period and decreases total time spent off the chest. However, as this was a simulation-based study, clinical implementation is necessary to further evaluate these potential benefits. [West J Emerg Med. 2014;15(2:246–250.

  6. Reliability analysis on resonance for low-pressure compressor rotor blade based on least squares support vector machine with leave-one-out cross-validation

    Directory of Open Access Journals (Sweden)

    Haifeng Gao

    2015-04-01

    Full Text Available This research article analyzes the resonant reliability at the rotating speed of 6150.0 r/min for low-pressure compressor rotor blade. The aim is to improve the computational efficiency of reliability analysis. This study applies least squares support vector machine to predict the natural frequencies of the low-pressure compressor rotor blade considered. To build a more stable and reliable least squares support vector machine model, leave-one-out cross-validation is introduced to search for the optimal parameters of least squares support vector machine. Least squares support vector machine with leave-one-out cross-validation is presented to analyze the resonant reliability. Additionally, the modal analysis at the rotating speed of 6150.0 r/min for the rotor blade is considered as a tandem system to simplify the analysis and design process, and the randomness of influence factors on frequencies, such as material properties, structural dimension, and operating condition, is taken into consideration. Back-propagation neural network is compared to verify the proposed approach based on the same training and testing sets as least squares support vector machine with leave-one-out cross-validation. Finally, the statistical results prove that the proposed approach is considered to be effective and feasible and can be applied to structural reliability analysis.

  7. Prediction of Maize Single Cross Hybrids Using the Total Effects of Associated Markers Approach Assessed by Cross-Validation and Regional Trials

    Directory of Open Access Journals (Sweden)

    Wagner Mateus Costa Melo

    2014-01-01

    Full Text Available The present study aimed to predict the performance of maize hybrids and assess whether the total effects of associated markers (TEAM method can correctly predict hybrids using cross-validation and regional trials. The training was performed in 7 locations of Southern Brazil during the 2010/11 harvest. The regional assays were conducted in 6 different South Brazilian locations during the 2011/12 harvest. In the training trial, 51 lines from different backgrounds were used to create 58 single cross hybrids. Seventy-nine microsatellite markers were used to genotype these 51 lines. In the cross-validation method the predictive accuracy ranged from 0.10 to 0.96, depending on the sample size. Furthermore, the accuracy was 0.30 when the values of hybrids that were not used in the training population (119 were predicted for the regional assays. Regarding selective loss, the TEAM method correctly predicted 50% of the hybrids selected in the regional assays. There was also loss in only 33% of cases; that is, only 33% of the materials predicted to be good in training trial were considered to be bad in regional assays. Our results show that the predictive validation of different crop conditions is possible, and the cross-validation results strikingly represented the field performance.

  8. Implantable defibrillators improve survival in patients with mildly symptomatic heart failure receiving cardiac resynchronization therapy

    DEFF Research Database (Denmark)

    Gold, Michael R; Daubert, Jean-Claude; Abraham, William T;

    2013-01-01

    Cardiac resynchronization therapy (CRT) decreases mortality, improves functional status, and induces reverse left ventricular remodeling in selected populations with heart failure. These benefits have been noted with both CRT-pacemakers as well as those devices with defibrillator backup (CRT...

  9. Use of automated external defibrillators in a Brazilian airline. A 1-year experience

    Directory of Open Access Journals (Sweden)

    Alves Paulo Magalhães

    2001-01-01

    Full Text Available After the incorporation of automated external defibrilators by other airlines and the support of the Brazilian Society of cardiology, Varig Airlines Began the onboard defibrilation program with the initial purpose of equiping wide-body aircrafts frequently used in international flights and that airplanes use in the Rio - São Paulo route. With all fight attendants trained, the automated. External defibrilation devides were incorporated to 34 airplanes of a total pleet of 80 aircrats. The devices were intalled in the bagage compartments secured with velero straps and 2 pairs of electrods, one or which pre-conected to the device to minimize application time. Later, a portable monitor was addres to the ressocitation kit in the long flights. The expansion of the knowledge of the basic life support fundamentors and the correted implantation of the survival chain and of the automated external defibrilators will increase the extense of recovery of cardiorespiratory arrest victins in aircrafts.

  10. Development of standard test methods for evaluating defibrillation recovery characteristics of disposable ECG electrodes.

    Science.gov (United States)

    Schoenberg, A A; Booth, H E; Lyon, P C

    1979-01-01

    A clinically relevant test for the measurement of defibrillation overload recovery of prefilled disposable ECG electrodes was developed and is proposed for use in an ECG electrode standard under development by AAMI. Defibrillation overload voltages and currents, as well as electrode polarization recovery voltages, were first measured in animal tests on 12 types of electrodes to allow correlation with various bench tests using a capacitor discharge at 10, 200, or 1000 V. Current overloads absorbed by the electrodes under worst conditions in animal tests were in the range of 2 percent of the defibrillation current flowing through the chest. These overloads were absorbed by most Ag-AgCl electrodes without excessive polarization. However, stainless steel, brass, and tin electrodes tended to polarize to levels that would saturate many ECG monitors. A standard bench test using a 200-V 10-muF capacitor was recommended for inclusion in the AAMI standard to determine whether electrodes are acceptable for use during defibrillation.

  11. Hands-on defibrillation: theoretical and practical aspects of patient and rescuer safety.

    Science.gov (United States)

    Petley, Graham W; Cotton, Angela M; Deakin, Charles D

    2012-05-01

    Defibrillators are used to treat many thousands of people each year using very high voltages, but, despite this, reported injuries to rescuers are rare. Although even a small number of reported injuries is not ideal, the safety record of the defibrillator using the current protocol is widely regarded as being acceptable. There is increasing evidence that clinical outcome is significantly improved with continuous chest compressions, but defibrillation is a common cause of interruptions; even short interruptions, such as those associated with defibrillation, may detrimentally affect the outcome. This has led to discussions regarding the possibility of continuing chest compressions during defibrillation; a process involving a rescuer working in close proximity to voltages of up to 5000 V. Not only do voltages of this magnitude have significant implications for the rescuer performing chest compressions, but there are also risks to other rescuers in the proximity, the patient and other bystanders. Clearly any deviation from accepted practice should only be undertaken following careful consideration of the risks and benefits to the patient, rescuers and others. This review summarises the physical principles of electrical risk and identifies ways in which these could be managed. In doing so, it is hoped that in future it may be possible to deliver continuous and safe manual chest compressions during defibrillator discharge in order to improve patient outcome. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  12. Public access defibrillators and fire extinguishers: are comparisons reasonable?

    Science.gov (United States)

    Mell, Howard K; Sayre, Michael R

    2008-01-01

    Sudden cardiac death is a major cause of mortality in the United States of America (Circulation 2008;117:e25-146) with approximately 310000 deaths related to coronary heart disease occurring in emergency departments or in the prehospital environment annually. Several organizations have directed resources toward the treatment of sudden cardiac arrest through a paradigm that has come to be known as the "chain of survival"-prompt activation of emergency response by telephone 911, early bystander cardiopulmonary resuscitation, early defibrillation, and timely advanced cardiac life support (Circulation 1991;83:1832-1847). The ready availability of automated external defibrillators (AEDs) has been advocated as a key component of this chain. Some authors have suggested a "fire extinguisher model" for AED deployment (Circulation 1998;98:2334-2351; Resuscitation 1995;30:151-156; Ann Intern Med 2001;135:990-998). In this model, AEDs are prominently displayed in public places for use by laypersons, much like fire extinguishers. For example, in Chicago's O'Hare Airport, AEDs are placed alongside fire extinguishers in the public concourse (N Engl J Med 2002;347:1242-1247). Advocates of this model suggest that advancing this practice would be a means to widely disbourse life-saving technology that is easy to use. Several experts have questioned this model, suggesting that the cost-effectiveness of distributing AEDs this widely would be prohibitive (BMJ 2002;325:515; Curr Opin Cardiol 2007;22:5-10; BMJ 2003;326:162; Int J Technol Assess Health Care 2007;23:362-367) and may not be more effective than more targeted distribution of AEDs. This literature review will examine the available data on both AEDs and fire extinguishers to determine if these comparisons are reasonable as a means of guiding public policy.

  13. Optimizing a Drone Network to Deliver Automated External Defibrillators.

    Science.gov (United States)

    Boutilier, Justin J; Brooks, Steven C; Janmohamed, Alyf; Byers, Adam; Buick, Jason E; Zhan, Cathy; Schoellig, Angela P; Cheskes, Sheldon; Morrison, Laurie J; Chan, Timothy C Y

    2017-03-02

    Background -Public access defibrillation programs can improve survival after out-of-hospital cardiac arrest (OHCA), but automated external defibrillators (AEDs) are rarely available for bystander use at the scene. Drones are an emerging technology that can deliver an AED to the scene of an OHCA for bystander use. We hypothesize that a drone network designed with the aid of a mathematical model combining both optimization and queuing can reduce the time to AED arrival. Methods -We applied our model to 53,702 OHCAs that occurred in the eight regions of the Toronto Regional RescuNET between January 1st 2006 and December 31st 2014. Our primary analysis quantified the drone network size required to deliver an AED one, two, or three minutes faster than historical median 911 response times for each region independently. A secondary analysis quantified the reduction in drone resources required if RescuNET was treated as one large coordinated region. Results -The region-specific analysis determined that 81 bases and 100 drones would be required to deliver an AED ahead of median 911 response times by three minutes. In the most urban region, the 90th percentile of the AED arrival time was reduced by 6 minutes and 43 seconds relative to historical 911 response times in the region. In the most rural region, the 90th percentile was reduced by 10 minutes and 34 seconds. A single coordinated drone network across all regions required 39.5% fewer bases and 30.0% fewer drones to achieve similar AED delivery times. Conclusions -An optimized drone network designed with the aid of a novel mathematical model can substantially reduce the AED delivery time to an OHCA event.

  14. Quantification of rainfall prediction uncertainties using a cross-validation based technique. Methodology description and experimental validation.

    Science.gov (United States)

    Fraga, Ignacio; Cea, Luis; Puertas, Jerónimo; Salsón, Santiago; Petazzi, Alberto

    2016-04-01

    In this paper we present a new methodology to compute rainfall fields including the quantification of predictions uncertainties using raingauge network data. The proposed methodology comprises two steps. Firstly, the ordinary krigging technique is used to determine the estimated rainfall depth in every point of the study area. Then multiple equi-probable errors fields, which comprise both interpolation and measuring uncertainties, are added to the krigged field resulting in multiple rainfall predictions. To compute these error fields first the standard deviation of the krigging estimation is determined following the cross-validation based procedure described in Delrieu et al. (2014). Then, the standard deviation field is sampled using non-conditioned Gaussian random fields. The proposed methodology was applied to study 7 rain events in a 60x60 km area of the west coast of Galicia, in the Northwest of Spain. Due to its location at the junction between tropical and polar regions, the study area suffers from frequent intense rainfalls characterized by a great variability in terms of both space and time. Rainfall data from the tipping bucket raingauge network operated by MeteoGalicia were used to estimate the rainfall fields using the proposed methodology. The obtained predictions were then validated using rainfall data from 3 additional rain gauges installed within the CAPRI project (Probabilistic flood prediction with high resolution hydrologic models from radar rainfall estimates, funded by the Spanish Ministry of Economy and Competitiveness. Reference CGL2013-46245-R.). Results show that both the mean hyetographs and the peak intensities are correctly predicted. The computed hyetographs present a good fit to the experimental data and most of the measured values fall within the 95% confidence intervals. Also, most of the experimental values outside the confidence bounds correspond to time periods of low rainfall depths, where the inaccuracy of the measuring devices

  15. Use of Automated External Defibrillators in Cardiac Arrest

    Science.gov (United States)

    2005-01-01

    Executive Summary Objective The objectives were to identify the components of a program to deliver early defibrillation that optimizes the effectiveness of automated external defibrillators (AEDs) in out-of-hospital and hospital settings, to determine whether AEDs are cost-effective, and if cost-effectiveness was determined, to advise on how they should be distributed in Ontario. Clinical Need Survival in people who have had a cardiac arrest is low, especially in out-of-hospital settings. With each minute delay in defibrillation from the onset of cardiac arrest, the probability of survival decreases by 10%. (1) Early defibrillation (within 8 minutes of a cardiac arrest) has been shown to improve survival outcomes in these patients. However, in out-of-hospital settings and in certain areas within a hospital, trained personnel and their equipment may not be available within 8 minutes. This implies that “first responders” should take up the responsibility of delivering shock. The first responders in out-of-hospital settings are usually bystanders, firefighters, police, and community volunteers. In hospital settings, they are usually nurses. These first responders are not trained in reading electrocardiograms and identifying abnormal heart rhythms restorable by defibrillation. The Technology An AED is a device that can analyze a heart rhythm and deliver a shock if needed. Thus, AEDs can be used by first responders to deliver early defibrillation in out-of-hospital and hospital settings. However, simply providing an AED would not likely improve survival outcomes. Rather, AEDs have a role in strengthening the “chain of survival,” which includes prompt activation of the 911 telephone system, early cardiopulmonary resuscitation (CPR), rapid defibrillation, and timely advanced life support. In the chain of survival, the first step for a witness of a cardiac arrest in an out-of-hospital setting is to call 911. Second, the witness initiates CPR (if she or he is

  16. Effect of Metoprolol Versus Carvedilol on Outcomes in MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy)

    DEFF Research Database (Denmark)

    Ruwald, Martin H; Ruwald, Anne-Christine H; Jøns, Christian;

    2013-01-01

    This study sought to compare the effects of metoprolol and carvedilol in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy) study.......This study sought to compare the effects of metoprolol and carvedilol in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy) study....

  17. Comparison of a new expert elicitation model with the Classical Model, equal weights and single experts, using a cross-validation technique

    Energy Technology Data Exchange (ETDEWEB)

    Flandoli, F. [Dip.to di Matematica Applicata, Universita di Pisa, Pisa (Italy); Giorgi, E. [Dip.to di Matematica Applicata, Universita di Pisa, Pisa (Italy); Istituto Nazionale di Geofisica e Vulcanologia, Sezione di Pisa, via della Faggiola 32, 56126 Pisa (Italy); Aspinall, W.P. [Dept. of Earth Sciences, University of Bristol, and Aspinall and Associates, Tisbury (United Kingdom); Neri, A., E-mail: neri@pi.ingv.it [Istituto Nazionale di Geofisica e Vulcanologia, Sezione di Pisa, via della Faggiola 32, 56126 Pisa (Italy)

    2011-10-15

    The problem of ranking and weighting experts' performances when quantitative judgments are being elicited for decision support is considered. A new scoring model, the Expected Relative Frequency model, is presented, based on the closeness between central values provided by the expert and known values used for calibration. Using responses from experts in five different elicitation datasets, a cross-validation technique is used to compare this new approach with the Cooke Classical Model, the Equal Weights model, and individual experts. The analysis is performed using alternative reward schemes designed to capture proficiency either in quantifying uncertainty, or in estimating true central values. Results show that although there is only a limited probability that one approach is consistently better than another, the Cooke Classical Model is generally the most suitable for assessing uncertainties, whereas the new ERF model should be preferred if the goal is central value estimation accuracy. - Highlights: > A new expert elicitation model, named Expected Relative Frequency (ERF), is presented. > A cross-validation approach to evaluate the performance of different elicitation models is applied. > The new ERF model shows the best performance with respect to the point-wise estimates.

  18. Derivation and Cross-Validation of Cutoff Scores for Patients With Schizophrenia Spectrum Disorders on WAIS-IV Digit Span-Based Performance Validity Measures.

    Science.gov (United States)

    Glassmire, David M; Toofanian Ross, Parnian; Kinney, Dominique I; Nitch, Stephen R

    2016-06-01

    Two studies were conducted to identify and cross-validate cutoff scores on the Wechsler Adult Intelligence Scale-Fourth Edition Digit Span-based embedded performance validity (PV) measures for individuals with schizophrenia spectrum disorders. In Study 1, normative scores were identified on Digit Span-embedded PV measures among a sample of patients (n = 84) with schizophrenia spectrum diagnoses who had no known incentive to perform poorly and who put forth valid effort on external PV tests. Previously identified cutoff scores resulted in unacceptable false positive rates and lower cutoff scores were adopted to maintain specificity levels ≥90%. In Study 2, the revised cutoff scores were cross-validated within a sample of schizophrenia spectrum patients (n = 96) committed as incompetent to stand trial. Performance on Digit Span PV measures was significantly related to Full Scale IQ in both studies, indicating the need to consider the intellectual functioning of examinees with psychotic spectrum disorders when interpreting scores on Digit Span PV measures. © The Author(s) 2015.

  19. Management of radiation therapy patients with cardiac defibrillator or pacemaker.

    Science.gov (United States)

    Salerno, Francesca; Gomellini, Sara; Caruso, Cristina; Barbara, Raffaele; Musio, Daniela; Coppi, Tamara; Cardinale, Mario; Tombolini, Vincenzo; de Paula, Ugo

    2016-06-01

    The increasing growth of population with cardiac implantable electronic devices (CIEDs) such as Pacemaker (PM) and Implantable Cardiac Defibrillators (ICD), requires particular attention in management of patients needing radiation treatment. This paper updates and summarizes some recommendations from different international guidelines. Ionizing radiation and/or electromagnetic interferences could cause device failure. Current approaches to treatment in patients who have these devices vary among radiation oncology centres. We refer to the German Society of Radiation Oncology and Cardiology guidelines (ed. 2015); to the Society of Cardiology Australia and New Zealand Statement (ed. 2015); to the guidelines in force in the Netherlands (ed. 2012) and to the Italian Association of Radiation Oncology recommendations (ed. 2013) as reported in the guidelines for the treatment of breast cancer in patients with CIED. Although there is not a clear cut-off point, risk of device failure increases with increasing doses. Cumulative dose and pacing dependency have been combined to categorize patients into low-, medium- and high-risk groups. Measures to secure patient safety are described for each category. The use of energy ≤6MV is preferable and it's strongly recommended not to exceed a total dose of 2 Gy to the PM and 1 Gy for ICD. Given the dangers of device malfunction, radiation oncology departments should adopt all the measures designed to minimize the risk to patients. For this reason, a close collaboration between cardiologist, radiotherapist and physicist is necessary.

  20. Virtual electrodes around anatomical structures and their roles in defibrillation

    Science.gov (United States)

    Vigmond, Edward; Bishop, Martin

    2017-01-01

    Background Virtual electrodes from structural/conductivity heterogeneities are known to elicit wavefront propagation, upon field-stimulation, and are thought to be important for defibrillation. In this work we investigate how the constitutive and geometrical parameters associated with such anatomical heterogeneities, represented by endo/epicardial surfaces and intramural surfaces in the form of blood-vessels, affect the virtual electrode patterns produced. Methods and results The steady-state bidomain model is used to obtain, using analytical and numerical methods, the virtual electrode patterns created around idealized endocardial trabeculations and blood-vessels. The virtual electrode pattern around blood-vessels is shown to be composed of two dominant effects; current traversing the vessel surface and conductivity heterogeneity from the fibre-architecture. The relative magnitudes of these two effects explain the swapping of the virtual electrode polarity observed, as a function of the vessel radius, and aid in the understanding of the virtual electrode patterns predicted by numerical bidomain modelling. The relatively high conductivity of blood, compared to myocardium, is shown to cause stronger depolarizations in the endocardial trabeculae grooves than the protrusions. Conclusions The results provide additional quantitative understanding of the virtual electrodes produced by small-scale ventricular anatomy, and highlight the importance of faithfully representing the physiology and the physics in the context of computational modelling of field stimulation. PMID:28253365

  1. [Training program on cardiopulmonary resuscitation with the use of automated external defibrillator in a university].

    Science.gov (United States)

    Boaventura, Ana Paula; Miyadahira, Ana Maria Kazue

    2012-03-01

    Early defibrillation in cardiopulmonary resuscitation (CPR) receives increasing emphasis on its priority and rapidity. This is an experience report about the implementation of a training program in CPR using a defibrillator in a private university. The training program in basic CPR maneuvers was based on global guidelines, including a theorical course with practical demonstration of CPR maneuvers with the defibrillator, individual practical training and theoretical and practical assessments. About the performance of students in the practical assessment the mean scores obtained by students in the first stage of the course was 26.4 points, while in the second stage the mean was 252.8 points, in the theoretical assessment the mean in the first stage was 3.06 points and in the second 9.0 points. The implementation of programs like this contribute to the effective acquisition of knowledge (theory) and skill (pratice) for the care of CPR victims.

  2. The Effects of Public Access Defibrillation on Survival After Out-of-Hospital Cardiac Arrest

    DEFF Research Database (Denmark)

    Bækgaard, Josefine; Viereck, Søren; Møller, Thea

    2017-01-01

    into three groups according to who applied the defibrillator: non-dispatched lay first responders, professional first responders (firefighters/police) dispatched by the Emergency Medical Dispatch Center (EMDC) or lay first responders dispatched by the EMDC. Results -A total of 41 studies were included; 18...... reported PAD by non-dispatched lay first responders, 20 reported PAD by EMDC-dispatched professional first responders (firefighters/police) and three reported both. We identified no qualified studies reporting survival after PAD by EMDC-dispatched lay first responders. The overall survival to hospital...... discharge after OHCA treated with PAD showed a median of 40.0% (range 9.1-83.3). Defibrillation by non-dispatched lay first responders was associated with the highest survival with a median of 53.0% (range 26.0-72.0) while defibrillation by EMDC-dispatched professional first responders (firefighters...

  3. Defibrillation delivered during the upstroke phase of manual chest compression improves shock success.

    Science.gov (United States)

    Li, Yongqin; Wang, Hao; Cho, Jun Hwi; Quan, Weilun; Freeman, Gary; Bisera, Joe; Weil, Max Harry; Tang, Wanchun

    2010-03-01

    The current standard of manual chest compression during cardiopulmonary resuscitation requires pauses for rhythm analysis and shock delivery. However, interruptions of chest compression greatly decrease the likelihood of successful defibrillations, and significantly better outcomes are reported if this interruption is avoided. We therefore undertook a prospective randomized controlled animal study in an electrically induced ventricular fibrillation pig model to assess the effects of timing of defibrillation on the manual chest compression cycle on the defibrillation threshold. Prospective, randomized, controlled animal study. University-affiliated research laboratory. Yorkshire-X domestic pigs (Sus scrofa). In eight domestic male pigs weighing between 24 and 31 kg, ventricular fibrillation was electrically induced and untreated for 10 secs. Manual chest compression was then performed and continued for 25 secs with the protection of an isolation blanket. The depth and frequency of chest compressions were guided by a cardiopulmonary resuscitation prompter. Animals were randomized to receive a biphasic electrical shock in five different compression phases with a predetermined energy setting. A control phase was chosen at a constant 2 secs after discontinued chest compression. A grouped up-down defibrillation threshold testing protocol was used to compare the success rate at different coupling phases. After a recovery interval of 4 mins, the sequence was repeated for a total of 60 test shocks for each animal. No difference in coronary perfusion pressure before delivering of the shock was observed among the six study phases. The defibrillation success rate, however, was significantly higher when shocks were delivered in the upstroke phase of manual chest compression. Defibrillation efficacy is maximal when electrical shock is delivered during the upstroke phase of manual chest compression.

  4. Complex Tricuspid Valve Repair in Patients With Pacer Defibrillator-Related Tricuspid Regurgitation.

    Science.gov (United States)

    Raman, Jaishankar; Sugeng, Lissa; Lai, David T M; Jeevanandam, Valluvan

    2016-04-01

    Tricuspid valve regurgitation in patients with heart failure or in those undergoing complex cardiac operations is associated with increased morbidity and mortality. We report our results with a technique of repairing the tricuspid valves while retaining the pacer defibrillator lead. Patients had tricuspid valve repairs that included repositioning of the pacer defibrillator lead, approximation of septal and inferior/posterior leaflets in a modified cleft repair, and implantation of a tricuspid annuloplasty ring. This procedure was performed in more than 42 patients with good success.

  5. Cross-validation of three predictive tools for non-sentinel node metastases in breast cancer patients with micrometastases or isolated tumor cells in the sentinel node

    DEFF Research Database (Denmark)

    Tvedskov, T F; Meretoja, T J; Jensen, M B

    2014-01-01

    BACKGROUND: We cross-validated three existing models for the prediction of non-sentinel node metastases in patients with micrometastases or isolated tumor cells (ITC) in the sentinel node, developed in Danish and Finnish cohorts of breast cancer patients, to find the best model to identify patients...... who might benefit from further axillary treatment. MATERIAL AND METHOD: Based on 484 Finnish breast cancer patients with micrometastases or ITC in sentinel node a model has been developed for the prediction of non-sentinel node metastases. Likewise, two separate models have been developed in 1577...... metastases while less than 1% was identified by the Finish model. In contrast, the Finish model predicted a much larger proportion of patients being in the low-risk group with less than 10% risk of non-sentinel node metastases. CONCLUSION: The Danish model for micrometastases worked well in predicting high...

  6. Electrochemical Performance and Stability of the Cathode for Solid Oxide Fuel Cells. I. Cross Validation of Polarization Measurements by Impedance Spectroscopy and Current-Potential Sweep

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Xiao Dong; Pederson, Larry R.; Templeton, Jared W.; Stevenson, Jeffry W.

    2009-12-09

    The aim of this paper is to address three issues in solid oxide fuel cells: (1) cross-validation of the polarization of a single cell measured using both dc and ac approaches, (2) the precise determination of the total areal specific resistance (ASR), and (3) understanding cathode polarization with LSCF cathodes. The ASR of a solid oxide fuel cell is a dynamic property, meaning that it changes with current density. The ASR measured using ac impedance spectroscopy (low frequency interception with real Z´ axis of ac impedance spectrum) matches with that measured from a dc IV sweep (the tangent of dc i-V curve). Due to the dynamic nature of ASR, we found that an ac impedance spectrum measured under open circuit voltage or on a half cell may not represent cathode performance under real operating conditions, particularly at high current density. In this work, the electrode polarization was governed by the cathode activation polarization; the anode contribution was negligible.

  7. Body fat measurement by bioelectrical impedance and air displacement plethysmography: a cross-validation study to design bioelectrical impedance equations in Mexican adults

    Directory of Open Access Journals (Sweden)

    Valencia Mauro E

    2007-08-01

    Full Text Available Abstract Background The study of body composition in specific populations by techniques such as bio-impedance analysis (BIA requires validation based on standard reference methods. The aim of this study was to develop and cross-validate a predictive equation for bioelectrical impedance using air displacement plethysmography (ADP as standard method to measure body composition in Mexican adult men and women. Methods This study included 155 male and female subjects from northern Mexico, 20–50 years of age, from low, middle, and upper income levels. Body composition was measured by ADP. Body weight (BW, kg and height (Ht, cm were obtained by standard anthropometric techniques. Resistance, R (ohms and reactance, Xc (ohms were also measured. A random-split method was used to obtain two samples: one was used to derive the equation by the "all possible regressions" procedure and was cross-validated in the other sample to test predicted versus measured values of fat-free mass (FFM. Results and Discussion The final model was: FFM (kg = 0.7374 * (Ht2 /R + 0.1763 * (BW - 0.1773 * (Age + 0.1198 * (Xc - 2.4658. R2 was 0.97; the square root of the mean square error (SRMSE was 1.99 kg, and the pure error (PE was 2.96. There was no difference between FFM predicted by the new equation (48.57 ± 10.9 kg and that measured by ADP (48.43 ± 11.3 kg. The new equation did not differ from the line of identity, had a high R2 and a low SRMSE, and showed no significant bias (0.87 ± 2.84 kg. Conclusion The new bioelectrical impedance equation based on the two-compartment model (2C was accurate, precise, and free of bias. This equation can be used to assess body composition and nutritional status in populations similar in anthropometric and physical characteristics to this sample.

  8. Remote sensing and GIS-based landslide hazard analysis and cross-validation using multivariate logistic regression model on three test areas in Malaysia

    Science.gov (United States)

    Pradhan, Biswajeet

    2010-05-01

    This paper presents the results of the cross-validation of a multivariate logistic regression model using remote sensing data and GIS for landslide hazard analysis on the Penang, Cameron, and Selangor areas in Malaysia. Landslide locations in the study areas were identified by interpreting aerial photographs and satellite images, supported by field surveys. SPOT 5 and Landsat TM satellite imagery were used to map landcover and vegetation index, respectively. Maps of topography, soil type, lineaments and land cover were constructed from the spatial datasets. Ten factors which influence landslide occurrence, i.e., slope, aspect, curvature, distance from drainage, lithology, distance from lineaments, soil type, landcover, rainfall precipitation, and normalized difference vegetation index (ndvi), were extracted from the spatial database and the logistic regression coefficient of each factor was computed. Then the landslide hazard was analysed using the multivariate logistic regression coefficients derived not only from the data for the respective area but also using the logistic regression coefficients calculated from each of the other two areas (nine hazard maps in all) as a cross-validation of the model. For verification of the model, the results of the analyses were then compared with the field-verified landslide locations. Among the three cases of the application of logistic regression coefficient in the same study area, the case of Selangor based on the Selangor logistic regression coefficients showed the highest accuracy (94%), where as Penang based on the Penang coefficients showed the lowest accuracy (86%). Similarly, among the six cases from the cross application of logistic regression coefficient in other two areas, the case of Selangor based on logistic coefficient of Cameron showed highest (90%) prediction accuracy where as the case of Penang based on the Selangor logistic regression coefficients showed the lowest accuracy (79%). Qualitatively, the cross

  9. Hands-on defibrillation: an analysis of electrical current flow through rescuers in direct contact with patients during biphasic external defibrillation.

    Science.gov (United States)

    Lloyd, Michael S; Heeke, Brian; Walter, Paul F; Langberg, Jonathan J

    2008-05-13

    Brief interruptions in chest compressions reduce the efficacy of resuscitation from cardiac arrest. Interruptions of this type are inevitable during hands-off periods for shock delivery to treat ventricular tachyarrhythmias. The safety of a rescuer remaining in contact with a patient being shocked with modern defibrillation equipment has not been investigated. This study measured the leakage voltage and current through mock rescuers while they were compressing the chests of 43 patients receiving external biphasic shocks. During the shock, the rescuer's gloved hand was pressed onto the skin of the patient's anterior chest. To simulate the worst case of an inadvertent return current pathway, a skin electrode on the rescuers thigh was connected to an electrode on the patient's shoulder. In no cases were shocks perceptible to the rescuer. Peak potential differences between the rescuer's wrist and thigh ranged from 0.28 to 14 V (mean 5.8+/-5.8 V). The average leakage current flowing through the rescuer's body for each phase of the shock waveform was 283+/-140 microA (range 18.9 to 907 microA). This was below several recommended safety standards for leakage current. Rescuers performing chest compressions during biphasic external defibrillation are exposed to low levels of leakage current. The present findings support the feasibility of uninterrupted chest compressions during shock delivery, which may enhance the efficacy of defibrillation and cardiocerebral resuscitation.

  10. Overcoming Spatial and Temporal Barriers to Public Access Defibrillators Via Optimization

    NARCIS (Netherlands)

    Sun, Christopher L.F.; Demirtas, Derya; Brooks, Steven C.; Morrison, Laurie J.; Chan, Timothy C.Y.

    2016-01-01

    Background Immediate access to an automated external defibrillator (AED) increases the chance of survival for out-of-hospital cardiac arrest (OHCA). Current deployment usually considers spatial AED access, assuming AEDs are available 24 h a day. Objectives The goal of this study was to develop an o

  11. Data management in automated external defibrillators: a call for a standardised solution

    DEFF Research Database (Denmark)

    Nielsen, Anne Møller; Rasmussen, L S

    2011-01-01

    The ECG data stored in automated external defibrillators (AEDs) may be valuable for establishing a final diagnosis and deciding further diagnostics and treatment. Different data management systems are used and this may create significant problems for data storage and access for physicians treatin...

  12. Out-of-hospital cardiac arrest and placement of automated external defibrillators in the community

    DEFF Research Database (Denmark)

    Folke, Fredrik

    2010-01-01

    INDLEDNING Chancen for at overleve et hjertestop udenfor hospital er i de første minutter efter kollaps afhængig af hjælpen fra nærmeste tilstedeværende. Dette har faciliteret strategier for placering af automatiske eksterne defibrillatorer (AED) i det offentlige rum og muliggjort hurtig defibril...

  13. Comparison of the effects of removal of chest hair with not doing so before external defibrillation on transthoracic impedance.

    Science.gov (United States)

    Sado, Daniel M; Deakin, Charles D; Petley, Graham W; Clewlow, Frank

    2004-01-01

    Chest hair contributes significantly to transthoracic impedance (TTI) during defibrillation. The magnitude of this effect has not been established using external paddles. We compared TTI in 40 men before elective cardiac surgery, and before and after shaving their chests. Chest hair causes a significant increase in TTI during external defibrillation, the magnitude of the effect being related to both the quantity of hair and force applied to the defibrillation paddles. When the chests of nonhirsute patients were shaved, a decrease in TTI occurred, which was probably related to the creation of low-impedance pathways through skin abrasions.

  14. Prevention of sudden death in hypertrophic cardiomyopathy (HCM):implanted defibrillators in HCM%肥厚型心肌病猝死预防:肥厚型心肌病患者除颤器置入

    Institute of Scientific and Technical Information of China (English)

    Barry J Maron; Paolo Spirito

    2009-01-01

    Hypertrophic cardiomyopathy (HCM) is the most common cause of sudden cardiac death in young people. The implantable cardioverter-defibrillator (ICD), has recently proved to be a safe and effective therapeutic intervention in patients with HCM, both for the primary and secondary prevention of sudden death. Based on recent substantial experience, the ICD intervenes appropriately to termiante ventricular tachycardia/fibrillation (VT/VF), at a rate of 5.5%/year. ICD discharge rate is 4%/year in those patients implanted prophylactically due to one or more major risk markers, but often with considerable delays of up to 10 years before the device is required to intervene appropriately to terminate potentially letal ventricular tachyarrhythmias. Primary prevention of VT/VF occurs with similar frequency in high-risk patients having either 1,2 or ≥ 3 noninvasive risk markers, and about one-third of patients with appropriate device interventions had been implanted for only one risk factor. The ICD has proved reliable in HCM despite the extreme and complex phenotypes often present with massive degrees of left vcntricular hypertrophy, microvascular ischemia, diastolic dysfunction, or dynamic left ventricular outflow tract obstruction. Failure to convert life-threatening ventrieular tachyarrhythmias to normal rhythm is extraordinarily rare. In conclusion, in high-risk HCM patients, ICDs perform in a highly effective fashion,frequently preventing sudden death by aborting primary life-threatening ventricular tachyarrhythmias. A single marker of high risk can be sufficient evidence to justify the recommendation for a prophylactic ICD in selected patients with HCM.

  15. End-tidal carbon dioxide and defibrillation success in out-of-hospital cardiac arrest.

    Science.gov (United States)

    Savastano, Simone; Baldi, Enrico; Raimondi, Maurizio; Palo, Alessandra; Belliato, Mirko; Cacciatore, Elisa; Corazza, Valentina; Molinari, Simone; Canevari, Fabrizio; Danza, Aurora I; Iotti, Giorgio Antonio; Visconti, Luigi Oltrona

    2017-09-20

    Basing on the relationship between the quality of cardiopulmonary resuscitation (CPR) and the responsiveness of VF to the defibrillation we aimed to assess whether the values of ETCO2 in the minute before defibrillation could predict the effectiveness of the shock. We retrospectively evaluated the reports generated by the manual monitor/defibrillator (Corpuls by GS Elektromedizinische Geräte G. Stemple GmbH, Germany) used for cases of VF cardiac arrest from January 2015 to December 2016. The mean ETCO2 value of the minute preceding the shock (METCO260) was computed. A blind evaluation of the effectiveness of each shock was provided by three cardiologists. A total amount of 207 shocks were delivered for 62 patients. When considering the three tertiles of METCO260 (T1:METCO260 ≤ 20mmHg; T2: 20mmHg 31mmHg) a statistically significant difference between the percentages of shock success was found (T1: 50%; T2: 63%; T3: 78%; Chi square p=0.003; p for trend <0.001). When the METCO260 was lower than 7mmHg no shock was effective and when the METCO260 was higher than 45mmHg no shock was ineffective. Shocks followed by ROSC were preceded by higher values of METCO260 as compared either to ineffective shocks or effective ones without ROSC. This is the first demonstration of the relation between ETCO2 and defibrillation effectiveness. Our findings stress the pivotal role of High Quality CPR, monitored via ETCO2, and suggest ETCO2 monitoring as an additional weapon to guide defibrillation. Copyright © 2017. Published by Elsevier B.V.

  16. Cost-effectiveness of automated external defibrillators on airlines.

    Science.gov (United States)

    Groeneveld, P W; Kwong, J L; Liu, Y; Rodriguez, A J; Jones, M P; Sanders, G D; Garber, A M

    2001-09-26

    Installation of automated external defibrillators (AEDs) on passenger aircraft has been shown to improve survival of cardiac arrest in that setting, but the cost-effectiveness of such measures has not been proven. To examine the costs and effectiveness of several different options for AED deployment in the US commercial air transportation system. Decision and cost-effectiveness analysis of a strategy of full deployment on all aircraft as well as several strategies of partial deployment only on larger aircraft, compared with a baseline strategy of no AEDs on aircraft (but training flight attendants in basic life support) for a hypothetical cohort of persons experiencing cardiac arrest aboard US commercial aircraft. Estimates for costs and outcomes were obtained from the medical literature, the Federal Aviation Administration, the Air Transport Association of America, a population-based cohort of Medicare patients, AED manufacturers, and the Bureau of Labor Statistics. Quality-adjusted survival after cardiac arrest; costs of AED deployment on aircraft and of medical care for cardiac arrest survivors. Adding AEDs on passenger aircraft with more than 200 passengers would cost $35 300 per quality-adjusted life-year (QALY) gained. Additional AEDs on aircraft with capacities between 100 and 200 persons would cost an additional $40 800 per added QALY compared with deployment on large-capacity aircraft only, and full deployment on all passenger aircraft would cost an additional $94 700 per QALY gained compared with limited deployment on aircraft with capacity greater than 100. Sensitivity analyses indicated that the quality of life, annual mortality rate, and the effectiveness of AEDs in improving survival were the most influential factors in the model. In 85% of Monte Carlo simulations, AED placement on large-capacity aircraft produced cost-effectiveness ratios of less than $50 000 per QALY. The cost-effectiveness of placing AEDs on commercial aircraft compares favorably

  17. Differences between out-of-hospital cardiac arrest in residential and public locations and implications for public-access defibrillation

    DEFF Research Database (Denmark)

    Folke, Fredrik; Gislason, Gunnar H; Lippert, Freddy

    2010-01-01

    The majority of out-of-hospital cardiac arrests (OHCAs) occur in residential locations, but knowledge about strategic placement of automated external defibrillators in residential areas is lacking. We examined whether residential OHCA areas suitable for placement of automated external...

  18. A qualitative study to identify barriers to deployment and student training in the use of automated external defibrillators in schools

    DEFF Research Database (Denmark)

    Zinckernagel, Line; Hansen, Carolina Malta; Rod, Morten Hulvej

    2017-01-01

    such as delayed access have been reported. The purpose of this study was to identify barriers to the implementation of defibrillator training of students and deployment of defibrillators in schools. METHODS: A qualitative study based on semi-structured individual interviews and focus groups with a total of 25...... participants, nine school leaders, and 16 teachers at eight different secondary schools in Denmark (2012-2013). Thematic analysis was used to identify regular patterns of meaning using the technology acceptance model and focusing on the concepts of perceived usefulness and perceived ease of use. RESULTS...... is suitable for defibrillator training. They were also ambiguous about deployment of defibrillators at schools. Those only accounting for the risk of students, considering their schools to be small, and that time for professional help was limited, found the relevance to be low. Due to safety concerns, some...

  19. Slips of Action and Sequential Decisions: A Cross-Validation Study of Tasks Assessing Habitual and Goal-Directed Action Control.

    Science.gov (United States)

    Sjoerds, Zsuzsika; Dietrich, Anja; Deserno, Lorenz; de Wit, Sanne; Villringer, Arno; Heinze, Hans-Jochen; Schlagenhauf, Florian; Horstmann, Annette

    2016-01-01

    Instrumental learning and decision-making rely on two parallel systems: a goal-directed and a habitual system. In the past decade, several paradigms have been developed to study these systems in animals and humans by means of e.g., overtraining, devaluation procedures and sequential decision-making. These different paradigms are thought to measure the same constructs, but cross-validation has rarely been investigated. In this study we compared two widely used paradigms that assess aspects of goal-directed and habitual behavior. We correlated parameters from a two-step sequential decision-making task that assesses model-based (MB) and model-free (MF) learning with a slips-of-action paradigm that assesses the ability to suppress cue-triggered, learnt responses when the outcome has been devalued and is therefore no longer desirable. MB control during the two-step task showed a very moderately positive correlation with goal-directed devaluation sensitivity, whereas MF control did not show any associations. Interestingly, parameter estimates of MB and goal-directed behavior in the two tasks were positively correlated with higher-order cognitive measures (e.g., visual short-term memory). These cognitive measures seemed to (at least partly) mediate the association between MB control during sequential decision-making and goal-directed behavior after instructed devaluation. This study provides moderate support for a common framework to describe the propensity towards goal-directed behavior as measured with two frequently used tasks. However, we have to caution that the amount of shared variance between the goal-directed and MB system in both tasks was rather low, suggesting that each task does also pick up distinct aspects of goal-directed behavior. Further investigation of the commonalities and differences between the MF and habit systems as measured with these, and other, tasks is needed. Also, a follow-up cross-validation on the neural systems driving these constructs

  20. Cross validation of gas chromatography-flame photometric detection and gas chromatography-mass spectrometry methods for measuring dialkylphosphate metabolites of organophosphate pesticides in human urine.

    Science.gov (United States)

    Prapamontol, Tippawan; Sutan, Kunrunya; Laoyang, Sompong; Hongsibsong, Surat; Lee, Grace; Yano, Yukiko; Hunter, Ronald Elton; Ryan, P Barry; Barr, Dana Boyd; Panuwet, Parinya

    2014-01-01

    We report two analytical methods for the measurement of dialkylphosphate (DAP) metabolites of organophosphate pesticides in human urine. These methods were independently developed/modified and implemented in two separate laboratories and cross validated. The aim was to develop simple, cost effective, and reliable methods that could use available resources and sample matrices in Thailand and the United States. While several methods already exist, we found that direct application of these methods required modification of sample preparation and chromatographic conditions to render accurate, reliable data. The problems encountered with existing methods were attributable to urinary matrix interferences, and differences in the pH of urine samples and reagents used during the extraction and derivatization processes. Thus, we provide information on key parameters that require attention during method modification and execution that affect the ruggedness of the methods. The methods presented here employ gas chromatography (GC) coupled with either flame photometric detection (FPD) or electron impact ionization-mass spectrometry (EI-MS) with isotopic dilution quantification. The limits of detection were reported from 0.10ng/mL urine to 2.5ng/mL urine (for GC-FPD), while the limits of quantification were reported from 0.25ng/mL urine to 2.5ng/mL urine (for GC-MS), for all six common DAP metabolites (i.e., dimethylphosphate, dimethylthiophosphate, dimethyldithiophosphate, diethylphosphate, diethylthiophosphate, and diethyldithiophosphate). Each method showed a relative recovery range of 94-119% (for GC-FPD) and 92-103% (for GC-MS), and relative standard deviations (RSD) of less than 20%. Cross-validation was performed on the same set of urine samples (n=46) collected from pregnant women residing in the agricultural areas of northern Thailand. The results from split sample analysis from both laboratories agreed well for each metabolite, suggesting that each method can produce