WorldWideScience

Sample records for cardiac sodium pump

  1. Intracellular sodium affects ouabain interaction with the Na/K pump in cultured chick cardiac myocytes

    OpenAIRE

    1990-01-01

    Whether a given dose of ouabain will produce inotropic or toxic effects depends on factors that affect the apparent affinity (K0.5) of the Na/K pump for ouabain. To accurately resolve these factors, especially the effect of intracellular Na concentration (Nai), we have applied three complementary techniques for measuring the K0.5 for ouabain in cultured embryonic chick cardiac myocytes. Under control conditions with 5.4 mM Ko, the value of the K0.5 for ouabain was 20.6 +/- 1.2, 12.3 +/- 1.7, ...

  2. Natriuretic peptides stimulate the cardiac sodium pump via NPR-C-coupled NOS activation.

    Science.gov (United States)

    William, M; Hamilton, E J; Garcia, A; Bundgaard, H; Chia, K K M; Figtree, G A; Rasmussen, H H

    2008-04-01

    Natriuretic peptides (NPs) and their receptors (NPRs) are expressed in the heart, but their effects on myocyte function are poorly understood. Because NPRs are coupled to synthesis of cGMP, an activator of the sarcolemmal Na(+)-K(+) pump, we examined whether atrial natriuretic peptide (ANP) regulates the pump. We voltage clamped rabbit ventricular myocytes and identified electrogenic Na(+)-K(+) pump current (arising from the 3:2 Na(+):K(+) exchange and normalized for membrane capacitance) as the shift in membrane current induced by 100 micromol/l ouabain. Ten nanomoles per liter ANP stimulated the Na(+)-K(+) pump when the intracellular compartment was perfused with pipette solutions containing 10 mmol/l Na(+) but had no effect when the pump was at near maximal activation with 80 mmol/l Na(+) in the pipette solution. Stimulation was abolished by inhibition of cGMP-activated protein kinase with KT-5823, nitric oxide (NO)-activated guanylyl cyclase with 1H-[1,2,4]oxadiazole[4,3-a]quinoxalin-1-one (ODQ), or NO synthase with N(G)-nitro-L-arginine methyl ester (L-NAME). Since synthesis of cGMP by NPR-A and NPR-B is not NO dependent or ODQ sensitive, we exposed myocytes to AP-811, a highly selective ligand for the NPR-C "clearance" receptor. It abolished ANP-induced pump stimulation. Conversely, the selective NPR-C agonist ANP(4-23) reproduced stimulation. The stimulation was blocked by l-NAME. To examine NO production in response to ANP(4-23), we loaded myocytes with the NO-sensitive fluorescent dye diacetylated diaminofluorescein-2 and examined them by confocal microscopy. ANP(4-23) induced a significant increase in fluorescence, which was abolished by L-NAME. We conclude that NPs stimulate the Na(+)-K(+) pump via an NPR-C and NO-dependent pathway. PMID:18272821

  3. Natriuretic peptides stimulate the cardiac sodium pump via NPR-C-coupled NOS activation

    DEFF Research Database (Denmark)

    William, M.; Hamilton, E.J.; Garcia, A.;

    2008-01-01

    -sensitive fluorescent dye diacetylated diaminofluorescein-2 and examined them by confocal microscopy. ANP(4-23) induced a significant increase in fluorescence, which was abolished by L-NAME. We conclude that NPs stimulate the Na(+)-K(+) pump via an NPR-C and NO-dependent pathway Udgivelsesdato: 2008/4...

  4. Pump tank divider plate for sump suction sodium pumps

    International Nuclear Information System (INIS)

    A circular plate extends across the diameter of a sump suction pump, with a close clearance between the edge of the plate and the wall of the pump tank. The plate is located above the pump impeller, inlet and outlet flow nozzles but below the sodium free surface and effectively divides the pump tank into two separate chambers. On change of pump speed, the close fitting flow restriction plate limits the rate of flow into or out of the upper chamber, thereby minimizing the rate of level change in the tank and permitting time for the pump cover gas pressure to be varied to maintain an essentially constant level. 4 claims, 3 figures

  5. Mechanical Blood Pumps for Cardiac Assistance

    Directory of Open Access Journals (Sweden)

    M. Akdis

    2005-01-01

    Full Text Available Cardiac assist devices are classified into the traditional engineering categories of displacement and rotary pumps. Clinical use and indications of the various pump categories are outlined and a detailed description of currently available systems is given. The first part deals with extracorporeal as well as implantable ventricular assist devices (VAD of the displacement type and is followed by a section on current developments in the field of total artificial hearts (TAH. The second part covers the rotary pump category from cardiopulmonary bypass applications to implantable systems, including specific design aspects of radial, diagonal, and axial pumps.

  6. Large sodium pump coastdown during an earthquake

    International Nuclear Information System (INIS)

    Analyses were performed to determine the responses of the main rotary element of a large sodium pump during the simultaneous occurrence of pump coastdown and a seismic event. Analytical procedures are described which enabled reduction of a multi-degree of freedom finite element model of the pump to a representative nonlinear single degree of freedom system with retention of acceptable computational accuracy. Pump rotor bearing impact forces and stresses, and the bearing rub forces which act throughout the pump coastdown were determined. Bearing material wear depth was calculated and an assessment was made of the effect of rub forces and the associated retarding torque on the shortening of pump coastdown time. Pump coastdown time can be very significantly shortened as a result of loss of rotor bearing stiffness and rubbing at the lower rotor speeds

  7. Mechanical Blood Pumps for Cardiac Assistance

    OpenAIRE

    Akdis, M; Reul, H

    2005-01-01

    Cardiac assist devices are classified into the traditional engineering categories of displacement and rotary pumps. Clinical use and indications of the various pump categories are outlined and a detailed description of currently available systems is given. The first part deals with extracorporeal as well as implantable ventricular assist devices (VAD) of the displacement type and is followed by a section on current developments in the field of total artificial hearts (TAH). The second part co...

  8. Na/K pump regulation of cardiac repolarization: insights from a systems biology approach

    KAUST Repository

    Bueno-Orovio, Alfonso

    2013-05-15

    The sodium-potassium pump is widely recognized as the principal mechanism for active ion transport across the cellular membrane of cardiac tissue, being responsible for the creation and maintenance of the transarcolemmal sodium and potassium gradients, crucial for cardiac cell electrophysiology. Importantly, sodium-potassium pump activity is impaired in a number of major diseased conditions, including ischemia and heart failure. However, its subtle ways of action on cardiac electrophysiology, both directly through its electrogenic nature and indirectly via the regulation of cell homeostasis, make it hard to predict the electrophysiological consequences of reduced sodium-potassium pump activity in cardiac repolarization. In this review, we discuss how recent studies adopting the systems biology approach, through the integration of experimental and modeling methodologies, have identified the sodium-potassium pump as one of the most important ionic mechanisms in regulating key properties of cardiac repolarization and its rate dependence, from subcellular to whole organ levels. These include the role of the pump in the biphasic modulation of cellular repolarization and refractoriness, the rate control of intracellular sodium and calcium dynamics and therefore of the adaptation of repolarization to changes in heart rate, as well as its importance in regulating pro-arrhythmic substrates through modulation of dispersion of repolarization and restitution. Theoretical findings are consistent across a variety of cell types and species including human, and widely in agreement with experimental findings. The novel insights and hypotheses on the role of the pump in cardiac electrophysiology obtained through this integrative approach could eventually lead to novel therapeutic and diagnostic strategies. © 2013 Springer-Verlag Berlin Heidelberg.

  9. Sodium Channel (Dys)Function and Cardiac Arrhythmias

    NARCIS (Netherlands)

    C.A. Remme; C.R. Bezzina

    2010-01-01

    P>Cardiac voltage-gated sodium channels are transmembrane proteins located in the cell membrane of cardiomyocytes. Influx of sodium ions through these ion channels is responsible for the initial fast upstroke of the cardiac action potential. This inward sodium current thus triggers the initiation an

  10. Sodium-sodium exchange through the sodium pump: the roles of ATP and ADP.

    Science.gov (United States)

    Cavieres, J D; Glynn, I M

    1979-12-01

    1. We have developed a procedure for preparing resealed red cell ghosts that contain ADP but very little ATP. 2. The procedure involves (i) lysis of the cells in a very large volume of lysing solution, (ii) resuspension of the ghosts in a small volume, (iii) the incorporation into the ghosts, before they are resealed, of the adenylate kinase inhibitor P1,P5-di(adenosine-5'-)pentaphosphate (AP5A) and of hexokinase, and (iv) the removal of traces of ATP, formed by residual adenylate kinase activity, by the addition of glucose. 3. Measurements of sodium efflux from ghosts prepared in this way show that sodium-sodium exchange through the sodium pump does not occur in the absence of ATP even if ADP is present. 4. The beta:gamma imido analogue of ATP (AMP.PNP), which is incapable of phosphorylating sodium, potassium-ATPase, cannot replace ATP in supporting sodium-sodium exchange. 5. These findings support the hypothesis that the outward movement of sodium ions through the sodium pump is associated with the transfer of a phosphoryl group from ATP to the enzyme, and that the inward movement of sodium ions through the pump is associated with the return of a phosphoryl group from the phosphoenzyme to ADP. PMID:536926

  11. Alignment and operability analysis of a vertical sodium pump

    International Nuclear Information System (INIS)

    With the objective of identifying important alignment features of pumps such as FFTF, HALLAM, EBR II, PNC, PHENIX, and CRBR, alignment of the vertical sodium pump for the Clinch River Breeder Reactor Plant (CRBRP) is investigated. The CRBRP pump includes a flexibly coupled pump shaft and motor shaft, two oil-film tilting-pad hydrodynamic radial bearings in the motor plus a vertical thrust bearing, and two sodium hydrostatic bearings straddling the double-suction centrifugal impeller in the pump

  12. Alignment and operability analysis of a vertical sodium pump

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, V.K.; Fair, C.E.

    1981-01-01

    With the objective of identifying important alignment features of pumps such as FFTF, HALLAM, EBR II, PNC, PHENIX, and CRBR, alignment of the vertical sodium pump for the Clinch River Breeder Reactor Plant (CRBRP) is investigated. The CRBRP pump includes a flexibly coupled pump shaft and motor shaft, two oil-film tilting-pad hydrodynamic radial bearings in the motor plus a vertical thrust bearing, and two sodium hydrostatic bearings straddling the double-suction centrifugal impeller in the pump.

  13. Genetic and environmental factors in cardiac sodium channel disease

    NARCIS (Netherlands)

    Y. Mizusawa

    2016-01-01

    Cardiac sodium channelopathies, such as long QT syndrome type3 (LQT3), Brugada syndrome (BrS) and cardiac conduction disease (CCD), are heritable diseases associated with mutations in the SCN5A gene and sudden cardiac death. They were classically thought to be a monogenic disease. However, while LQT

  14. Sodium pump organization in dendritic spines.

    Science.gov (United States)

    Blom, Hans; Bernhem, Kristoffer; Brismar, Hjalmar

    2016-10-01

    Advancement in fluorescence imaging with the invention of several super-resolution microscopy modalities (e.g., PALM/STORM and STED) has opened up the possibility of deciphering molecular distributions on the nanoscale. In our quest to better elucidate postsynaptic protein distribution in dendritic spines, we have applied these nanoscopy methods, where generated results could help improve our understanding of neuronal functions. In particular, we have investigated the principal energy transformer in the brain, i.e., the [Formula: see text]-ATPase (or sodium pump), an essential protein responsible for maintaining resting membrane potential and a major controller of intracellular ion homeostasis. In these investigations, we have focused on estimates of protein amount, giving assessments of how variations may depend on labeling strategies, sample analysis, and choice of nanoscopic imaging method, concluding that all can be critical factors for quantification. We present a comparison of these results and discuss the influences this may have for homeostatic sodium regulation in neurons and energy consumption. PMID:27175374

  15. Sodium removal from the mechanical pumps of Joyo

    International Nuclear Information System (INIS)

    Adjacent to the reactor main building a building for sodium component overhaul is prepared. This building contains a sodium cleaning facility for the primary main pump in addition to other facilities. In this paper the sodium cleaning facility and its cleaning process is described. Further, the function of this facility is evaluated using the result of cleaning tests and experiences of actual pump cleaning. (author)

  16. Fast Flux Test Facility replacement of a primary sodium pump

    International Nuclear Information System (INIS)

    The Fast Flux Test Facility is a 400 MW Thermal Sodium Cooled Fast Reactor operated by Westinghouse Hanford Company for the US Department of Energy. During startup testing in 1979, the sodium level in one of the primary sodium pumps was inadvertently raised above the normal height. This resulted in distortion of the pump shaft. Pump replacement was carried out using special maintenance equipment. Nuclear radiation and contamination were not significant problems since replacement operations were carried out shortly after startup of the Fast Flux Test Facility

  17. Modeling and performance research on sodium cooled fast reactor superconductive sodium pump

    International Nuclear Information System (INIS)

    In order to overcome the shortcoming of sodium cooled fast reactor mechanical sodium pump including mechanical wear, large noise, sodium leakage and the shortcoming of electromagnetic pump including small flow rate and small pump head, the large flow rate sodium pump design based on saddle superconductive magnet was put forward. The structure of sodium pump was researched and the mathematic model was established. The performance including pump head, flow rate and efficiency were researched at different currents, magnetic flux densities and temperatures using the computer code programmed with Matlab. The result shows that the pump head will reduce with the channel width increasing, current reducing and magnetic flux density reducing, and the efficiency will reduce with the current reducing and magnetic flux density reducing. If the temperature overtops 400 ℃, the efficiency will be high because of contact resistance disappearing. The flow rate of the saddle type superconductive sodium pump can be controlled by current and magnetic flux density, and the current is more suitable. This research can provide foundation for concreting design. (authors)

  18. Designing & Optimizing a Moving Magnet Pump for Liquid Sodium Systems

    Science.gov (United States)

    Hvasta, Michael G.

    Advanced materials such as NF-616, NF-709, HT-UPS, and silicon carbide (SiC) have greater strength than traditional structural materials such as 316-SS. Thus, using these high-strength materials to build sodium-cooled fast reactors (SFRs) could potentially reduce construction costs by lessening the required amount of material, and increase the efficiency of electromagnetic pumps by limiting ohmic heating within the pump duct walls. However, information pertaining to the sodium-compatibility of these alloys and ceramics is very sparse. Therefore, two separate test facilities were built to study the impact of both static and dynamic sodium corrosion The dynamic test facility enabled sodium corrosion to be studied under prototypic SFR operating conditions (T = 500 [C], V = 9.35 [m/s], CO = 2-3 [wppm]). The oxygen concentration, CO, within the dynamic test facility was maintained using a cold trap and measured with a plugging meter. The flow rate of the sodium was measured using a calibrated electromagnetic flowmeter. A moving magnet pump (MMP) was used to move the liquid sodium past the corrosion samples at a high velocity. Using newly developed theory, it was found that MMP performance could be accurately modeled and predicted for a wide variety of pump configurations.

  19. Functional studies of sodium pump isoforms

    DEFF Research Database (Denmark)

    Clausen, Michael Jakob

    The Na+,K+-ATPase is an essential ion pump found in all animal cells. It uses the energy from ATP hydrolysis to export three Na+ and import two K+, both against their chemical gradients and for Na+ also against the electrical potential. Mammals require four Na+,K+-ATPase isoforms that each have...... synthesized cohorts of pumps from the Golgi apparatus to the plasma membrane....

  20. The effects of vanadate on the fluxes of sodium and potassium ions through the sodium pump.

    Science.gov (United States)

    Beaugé, L A; Cavieres, J J; Glynn; Grantham, J J

    1980-04-01

    1. The effects of sodium orthovanadate on the fluxes of sodium and potassium (or rubidium) ions through the sodium pump have been investigated in intact human red cells and in resealed ghosts prepared from them. Sodium-potassium exchange, potassium-potassium exchange, pump reversal, sodium-sodium exchange and uncoupled sodium efflux have each been studied.2. When intact human red cells were incubated in high-sodium media containing vanadate in low concentrations, inhibition of potassium or rubidium influx was marked only if the potassium or rubidium concentration in the medium was sufficiently high to cause nearly maximal influx in the absence of vanadate. The absence of inhibition at lower potassium or rubidium concentrations cannot be explained by supposing that the onset of inhibition by vanadate is slower in these conditions.3. Lowering the extracellular sodium concentration, or raising the vanadate concentration, decreased the minimum concentration of extracellular potassium or rubidium at which inhibition by vanadate was detected.4. Experiments on potassium influx into intact red cells treated with the ionophore A23187 showed that magnesium ions act at intracellular sites to promote inhibition by vanadate.5. Measurements of potassium efflux from intact red cells incubated in high-sodium media, with or without potassium, showed that potassium-potassium exchange was inhibited by vanadate at low concentrations whereas reversal of the pump was not.6. Measurements of sodium efflux from intact red cells or resealed ghosts incubated in high-sodium media, with or without potassium, showed that vanadate had little or no effect on sodium-sodium exchange at concentrations at which sodium-potassium exchange was markedly reduced. Much higher concentrations of vanadate did cause partial inhibition of sodium-sodium exchange.7. Experiments to determine whether vanadate in low concentrations inhibited uncoupled sodium efflux were inconclusive, but suggested that the flux was

  1. Design of PFBR sodium pumps and their cavitation performance criteria

    International Nuclear Information System (INIS)

    The Prototype Fast Breeder Reactor (PFBR) currently under design in India is a 500 MWe sodium cooled reactor plant of pool design. The reactor will have four heat transport loops in the primary as well as the secondary. The total primary coolant flow is expected to be 32000 cubic metres/hr and the total pressure drop in the circuit within 80 mic. Primary sodium will be circulated by four pumps immersed in the cold sodium pool (400 deg. C) and supported from the roof structure. This paper discusses the design of the primary sodium pumps with particular reference to cavitation performance requirements. An outline of the experimental programme for the hydraulic development is also given

  2. Cardiac Bypass Pump Flow Management via NIRS Monitoring

    OpenAIRE

    Macnab, Andrew J.; Gagnon, Roy E.; Gagnon, Faith A.; Blackstock, Derek; LeBlanc, Jacques G.

    2003-01-01

    During cardiac surgery, bypass pumps rely on pressure monitors to evaluate flow. We studied whether it would be possible to optimize pump flow by monitoring changes in cerebral cytochrome a,a3 using NIRS to maintain cyt redox status at its pre-bypass level. Method: 18 healthy 7–45 kg swine were placed on bypass for repeated cycles of cooling and re-warming from 36 to 15 to 36°C in 3°C steps. Between each cycle, the swine's bypass pump blood flow rate was adjusted to restore cytochrome redox s...

  3. OUABAIN AND INSULIN INDUCE SODIUM PUMP ENDOCYTOSIS IN RENAL EPITHELIUM

    OpenAIRE

    Gupta, Shalini; Yan, Yanling; Malhotra, Deepak; Liu, Jiang; Xie, Zijian; Najjar, Sonia M.; Shapiro, Joseph I

    2012-01-01

    Cardiotonic steroids signaling through the basolateral sodium pump (Na/KATPase) have been shown to alter renal salt handling in intact animals. As the relationship between renal salt handling and blood pressure is a key determinant of hypertension, and patients with insulin resistance are frequently hypertensive, we chose to examine whether there might be competition for resources necessary for receptor mediated endocytosis.

  4. Periodic paralysis and the sodium-potassium pump.

    Science.gov (United States)

    Layzer, R B

    1982-06-01

    Analysis of the pathophysiology of hypokalemic paralysis, as it occurs in barium poisoning, chronic potassium deficiency, and thyrotoxicosis, suggests that these disorders may have a similar mechanism. An increased ratio of muscle sodium permeability to potassium permeability reduces the ionic diffusion potential, while the resting membrane potential is sustained by an increase of Na-K pump electrogenesis. The result is that potassium entry (the sum of active and passive influx) exceeds potassium efflux; this causes a large shift of extracellular potassium into muscle until the Na-K pump turns off, leading to depolarization and paralysis. The primary defect in familial hypokalemic periodic paralysis, as in the example of barium poisoning, may be a marked reduction of muscle permeability to potassium. PMID:6287910

  5. Chemical radiation protection of sodium pump in mammalian skeletal muscle

    International Nuclear Information System (INIS)

    When male albino rats of the Wistar strain received wholebody gamma irradiation at a dose level of 8.5 Gy, 22N outward movement from the diaphragm muscle fibres slowed down, while its uptake was enhanced. When imidazole was intraperitoneally injected prior to irradiation both movements returned nearly to normal rates. Experiments carried out on the 7th day post irradiation, indicated that gamma irradiation had exerted some sort of damage upon the sodium pumping mechanism in mammalian skeletal muscle, and that imidazole injection prior to radiation exposure exerted a remarkable radioprotective effect on those vital biophysical processes. The results have been discussed in view of the relevant literature. (author)

  6. Nonlinear seismic analysis of a large sodium pump

    International Nuclear Information System (INIS)

    The bearings and seismic bumpers used in a large sodium pump of a typical breeder reactor plant may need to be characterized by nonlinear springs and gaps. Then, nonlinear seismic analysis utilizing the time-history method is an effective way to predict the pump behaviors during seismic events, especially at those bearing and seismic bumper areas. In this study, synthesized time histories were developed based on specified seismic response spectra. A nonlinear seismic analysis was then conducted and results were compared with those obtained by linear seismic analysis using the response spectrum method. In contrast to some previous nonlinear analysis trends, the bearing impact forces predicted by nonlinear analysis were higher than those obtained by the response spectrum method. This might be due to the larger gaps and stiffer bearing supports used in this specific pump. However, at locations distant from the impact source, the nonlinear seismic analysis has predicted slightly less responses than those obtained by linear seismic analysis. The seismically induced bearing impact forces were used to study the friction induced thermal stresses on the hydrostatic bearing and to predict the coastdown time of the pump. Results and discussions are presented

  7. Mechanisms of pulmonary dysfunction after on-pump and off-pump cardiac surgery: a prospective cohort study

    OpenAIRE

    Jansen Evert K; Groeneveld AB Johan; Verheij Joanne

    2007-01-01

    Abstract Background Pulmonary dysfunction following cardiac surgery is believed to be caused, at least in part, by a lung vascular injury and/or atelectasis following cardiopulmonary bypass (CPB) perfusion and collapse of non-ventilated lungs. Methods To test this hypothesis, we studied the postoperative pulmonary leak index (PLI) for 67Ga-transferrin and (transpulmonary) extravascular lung water (EVLW) in consecutive patients undergoing on-pump (n = 31) and off-pump (n = 8) cardiac surgery. ...

  8. Cardiac sodium channel mutations: why so many phenotypes?

    Science.gov (United States)

    Liu, Man; Yang, Kai-Chien; Dudley, Samuel C.

    2016-01-01

    Mutations of the cardiac sodium channel (Nav1.5) can induce gain or loss of channel function. Gain-of-function mutations can cause long QT syndrome type 3 and possibly atrial fibrillation, whereas loss-of-function mutations are associated with a variety of phenotypes, such as Brugada syndrome, cardiac conduction disease, sick sinus syndrome, and possibly dilated cardiomyopathy. The phenotypes produced by Nav1.5 mutations vary according to the direct effect of the mutation on channel biophysics, but also with age, sex, body temperature, and between regions of the heart. This phenotypic variability makes genotype–phenotype correlations difficult. In this Perspectives article, we propose that phenotypic variability not ascribed to mutation-dependent changes in channel function might be the result of additional modifiers of channel behaviour, such as other genetic variation and alterations in transcription, RNA processing, translation, post-translational modifications, and protein degradation. Consideration of these modifiers might help to improve genotype–phenotype correlations and lead to new therapeutic strategies. PMID:24958080

  9. Sodium testing of intermediate-size inducer pump in SPTF at ETEC

    International Nuclear Information System (INIS)

    The overall test program includes pump assembly, installation, testing, removal from the test loop, disassembly and final inspection of the entire pump. Testing will include checkout tests, head/flow and efficiency characterizations at selected speeds and sodium temperatures, suction performance determination, a 2000 hour endurance test, and thermal transient tests. The pump will be cleaned of sodium, disassembled, and examined before the 2000 hour endurance test and after the thermal transient tests to determine the effects that long-term operation at 200 percent NPSH margin has on the pump components. The testing will be done at Energy Technology Engineering Center (ETEC). Assembly, sodium removal, disassembly, and initial inspection will be performed at Component Handling and Cleaning Facility (CHCF) and sodium testing will be done at Sodium Pump Test Facility

  10. Analysis on vibration characteristics of the primary sodium pump of China experimental fast reactor

    International Nuclear Information System (INIS)

    The article introduces the rotational model analysis and the vibration test of the primary sodium pump of China Experimental Fast Reactor. Through the establishment of the rotation of the shaft system model, the critical speed has been analyzed. Combined with the pump bearings and motor bearings at double amplitude and RMS vibration velocity measurement experiment, the results show that the vibration characteristics of the primary sodium pump meet the requirements of the operational limits. (author)

  11. Study on cavitation in centrifugal sodium pumps for FBTR and PFBR

    International Nuclear Information System (INIS)

    Fast Breeder Test Reactor (FBTR) which is expected to become critical shortly is a loop type reactor of 40 MW thermal capacity and has two primary and two secondary centrifugal pumps for heat removal. During the initial periods of reactor operation, the steam generator is bypassed and the secondary sodium pumps are required to operate at flows less than that at best efficiency point. This paper deals with the cavitation problems associated with operation at partial f lows, theoretical estimations and experimental cavitation measurements carried out on FBTR secondary sodium pumps. These investigations revealed that operation of FBTR pumps at this off design condition is free from cavitation damage. Cavitation experiments on a model pump for the development of large sodium pumps for a 500 MWe Prototype Fast Breeder Reactor (PFBR) are described in this paper

  12. Specialists' meeting on cavitation criteria for designing mechanisms working in sodium: Application to pumps. Summary report

    International Nuclear Information System (INIS)

    The purpose of the meeting was to provide a forum for discussions and exchanges of views on cavitation phenomena in sodium, cavitation tests on pump models in water and sodium, application of test results to LMFBR plants, impact on sodium pump design. Topics of interest were also detection methods for cavitation during tests and cavitation problems in electro-magnetic pumps. Two categories of papers were presented: national position papers and specialised topical papers. The main topics discussed, in three sessions were the following: National papers on cavitation; cavitation tests, performance, measuring methods and results; application of test results and implications on the future programmes

  13. Sodium testing of intermediate-size inducer pump in SPTF at ETEC

    International Nuclear Information System (INIS)

    The overall test program includes pump assembly, installation, testing, removal from the test loop, disassembly and final inspection of the entire pump. Testing will include checkout tests, head/flow and efficiency characterizations at selected speeds and sodium temperatures, suction performance determination, a 2000 hour design point endurance test, a 300 hour off design endurance test, and thermal transient tests. The pump will be cleaned of sodium, disassembled, and examined before the 2000 hour endurance test and after the thermal transient tests to determine the effects that long-term operation at 200 percent NPSH margin and off design operation at the same flow and NPSH have on the pump components

  14. Design and Testing of D.C. Conduction Pump for Sodium Cooled Fast Reactor

    International Nuclear Information System (INIS)

    DC Conduction pump immersed in sodium forms a part of Failed Fuel Location Module (FFLM) of 500 MWe Fast Breeder Reactor (PFBR) currently under construction. FFLM housed in control plug of the reactor, is used to locate the failed fuel sub-assembly due to clad rupture in the fuel pin. The DC conduction pump sucks the sodium from the top of fuel sub-assemblies through the selector valve and pumps the sodium to hold up for detecting the presence of delayed neutrons. Presence of delayed neutron is the indication of failure in the sampled fuel sub-assembly. The DC Conduction Pump was chosen because of its low voltage operation (2 V) where argon/alumina ceramic can provide required electrical insulation even at operating temperature of 560 deg. C without much complication on the manufacturing front. Sampling of sodium from top of different sub-assemblies is achieved by operation of selector valve in-conjunction with the drive motor. FFLM requires the pump to be immersed in sodium pool at ∼ 560 deg. C located above the fuel sub-assemblies in the reactor. The Pump of 0.36 m3/h capacity and developing 1.45 Kg/ cm2 pressure was designed, manufactured and tested. The DC Conduction Pump has a stainless steel duct filled with liquid sodium, which is to be pumped. The stainless steel duct is kept in magnetic field obtained by means of electromagnet. The electromagnet is made of soft iron and the coil made of copper conductor surrounds the yoke portion of electromagnet. The external DC source of 2000 Amps, 2 Volt is used to send current through sodium placed in the stainless steel duct and the same current is sent through copper coil of electromagnet for producing required magneto motive force, which in turn produces required magnetic field. The interaction of current in sodium (placed in stainless steel duct) and magnetic field produced by the electromagnet in the duct region produces pumping force in the sodium. Electromagnet, copper coil, stainless steel duct, copper bus

  15. Mechanisms of pulmonary dysfunction after on-pump and off-pump cardiac surgery: a prospective cohort study

    Directory of Open Access Journals (Sweden)

    Jansen Evert K

    2007-02-01

    Full Text Available Abstract Background Pulmonary dysfunction following cardiac surgery is believed to be caused, at least in part, by a lung vascular injury and/or atelectasis following cardiopulmonary bypass (CPB perfusion and collapse of non-ventilated lungs. Methods To test this hypothesis, we studied the postoperative pulmonary leak index (PLI for 67Ga-transferrin and (transpulmonary extravascular lung water (EVLW in consecutive patients undergoing on-pump (n = 31 and off-pump (n = 8 cardiac surgery. We also studied transfusion history, radiographs, ventilatory and gas exchange variables. Results The postoperative PLI and EVLW were elevated above normal in 42 and 29% after on-pump surgery and 63 and 37% after off-pump surgery, respectively (ns. Transfusion of red blood cell (RBC concentrates, PLI, EVLW, occurrence of atelectasis, ventilatory variables and duration of mechanical ventilation did not differ between groups, whereas patients with atelectasis had higher venous admixture and airway pressures than patients without atelectasis (P = 0.037 and 0.049. The PLI related to number of RBC concentrates infused (P = 0.025. Conclusion The lung vascular injury in about half of patients after cardiac surgery is not caused by CPB perfusion but by trauma necessitating RBC transfusion, so that off-pump surgery may not afford a benefit in this respect. However, atelectasis rather than lung vascular injury is a major determinant of postoperative pulmonary dysfunction, irrespective of CPB perfusion.

  16. Development of a sodium-pump/neon-lasant photopumped soft X-ray laser

    International Nuclear Information System (INIS)

    Resonant photopumping of heliumlike neon by heliumlike sodium is investigated to extend this potentially efficient technique for inversion and lasing to shorter wavelengths. Properties of the sodium-pump plasma and the neon-lasant plasma required to optimize fluorescence and lasing are determined. The implosion of a sodium-bearing plasma with a megampere pulsed-power driver (Gamble II) is used to produce a linear Z-pinch with up to 25 GW of sodium-pump-line radiation. A separate neon plasma, driven by part of the return current form the imploding sodium plasma, is created parallel to the sodium line source at a distance of 5 cm. Implosion requirements for the neon plasma and its dynamics in the Gamble II return-current geometry are described. Evidence for population inversion is indicated by fluorescence enhancement of the 11-A resonance line from the n = 4 level of neon when pumped by sodium. The neon spectra are in qualitative agreement with calculations based on the sodium-pump power. Improvements in the experiment required to achieve lasing are discussed

  17. SODIUM BICARBONATE INFUSION: TO PREVENT CARDIAC SURGERY - ASSOCIATED ACUTE KIDNEY INJURY

    Directory of Open Access Journals (Sweden)

    Ramesh

    2015-02-01

    Full Text Available OBJECTIVES: The incidence of cardiac surgery – associated acute kidney injury is 50% of patients and is associated with increased mortality and morbidity. This study aimed to determine if perioperative urinary and plasma alkalization with sodium bicarbonate infusion re duces the incidence of cardiac surgery – associated acute kidney injury. SETTING AND DESIGN: This study is double blind randomized control trial conducted at U N Mehta Institute of Cardiology and Research Center , India. METHOD S AND RESULT: A total of 140 pat ients scheduled to undergo elective cardiac surgery , who were at increased risk of development of cardiac surgery – associated acute kidney injury using recognized risk factors. Patients were randomly allocated to receive either sodium bicarbonate (n = 70 o r sodium chloride (n = 70 infusion , commencing at the start of anesthesia , in a dose of 4 mmol/kg over 24 hour. The primary outcome measure was the number of patients with development of CSA - AKI , defined as an increase in creatinine greater than 25% from baseline to peak value within the first three postoperative days. Significant differences among the groups in both plasma and urinary pH were achieved 6 hours after commencement of the infusion , and these changes persisted for more than 24 hours. A total o f 7 out of 70(10% patients in the sodium bicarbonate group and 16 out of 70(22.85% patients in the sodium chloride group developed acute kidney injury within the first three postoperative days with p value of 0.06 which is statistically not significant . There were also no significant differences in ventilation hours , ICU or hospital length of stay , or mortality. CONCLUSIONS: Perioperative alkalization of blood and urine using an infusion of sodium bicarbonate did not result in a decrease in the incidence of acute kidney injury in patients undergoing cardiac surgery. KEYWORDS: Acute kidney injury; Cardiac surgery; Cardiopulmonary bypass; Creatinine

  18. Crystal structure of the sodium-potassium pump

    DEFF Research Database (Denmark)

    Morth, J Preben; Pedersen, Bjørn Panyella; Toustrup-Jensen, Mads S;

    2007-01-01

    The Na+,K+-ATPase generates electrochemical gradients for sodium and potassium that are vital to animal cells, exchanging three sodium ions for two potassium ions across the plasma membrane during each cycle of ATP hydrolysis. Here we present the X-ray crystal structure at 3.5 A resolution of the...

  19. Increasing cardiac output and decreasing oxygenation sequence in pump twins of acardiac twin pregnancies

    International Nuclear Information System (INIS)

    An acardiac twin pregnancy is a rare but serious complication of monochorionic twinning and consists of an acardiac twin and a pump twin. The acardiac twin is a severely malformed fetus that lacks most organs, particularly a heart, but grows during pregnancy because it is perfused by the developmentally normal pump twin via a set of arterioarterial and venovenous placental anastomoses. Pump twins die intrauterine or neonatally in about 50% of the cases. Because the effects of an acardiac mass on the pump twin's development are incompletely known, methods for outcome prognosis are currently not available. We sought to derive simple relations for the pump twin's excess cardiac output and decreased oxygenation and to use available clinical cases for a preliminary test of the model. As a method, we used a theoretical flow model to represent the fetoplacental circulation of an acardiac twin pregnancy and estimated blood deoxygenation and reoxygenation following perfusion of the two bodies and placentas, respectively. The results show the pump twin's excess cardiac output and decrease of venous oxygen saturation to depend on the ratio of pump twin to acardiac twin umbilical blood flow, whose ratio can be measured by ultrasonography. The clinical cases show a decreasing umbilical flow ratio with gestation. In conclusion, prospective serial study is necessary to test whether measurement of umbilical flow ratios allows monitoring the pump twin's pathophysiologic development, possibly resulting in a guideline for prognosis of pump twin survival. (note)

  20. Increasing cardiac output and decreasing oxygenation sequence in pump twins of acardiac twin pregnancies

    Energy Technology Data Exchange (ETDEWEB)

    Gemert, Martin J C van [Laser Center and Department of Obstetrics and Gynecology, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam (Netherlands); Umur, Asli [Laser Center and Department of Obstetrics and Gynecology, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam (Netherlands); Wijngaard, Jeroen P H M van den [Laser Center and Department of Obstetrics and Gynecology, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam (Netherlands); VanBavel, Ed [Department of Medical Physics, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands); Vandenbussche, Frank P H A [Department of Obstetrics, Leiden University Medical Center, Leiden (Netherlands); Nikkels, Peter G J [Department of Pathology, University Medical Center, Utrecht (Netherlands)

    2005-02-07

    An acardiac twin pregnancy is a rare but serious complication of monochorionic twinning and consists of an acardiac twin and a pump twin. The acardiac twin is a severely malformed fetus that lacks most organs, particularly a heart, but grows during pregnancy because it is perfused by the developmentally normal pump twin via a set of arterioarterial and venovenous placental anastomoses. Pump twins die intrauterine or neonatally in about 50% of the cases. Because the effects of an acardiac mass on the pump twin's development are incompletely known, methods for outcome prognosis are currently not available. We sought to derive simple relations for the pump twin's excess cardiac output and decreased oxygenation and to use available clinical cases for a preliminary test of the model. As a method, we used a theoretical flow model to represent the fetoplacental circulation of an acardiac twin pregnancy and estimated blood deoxygenation and reoxygenation following perfusion of the two bodies and placentas, respectively. The results show the pump twin's excess cardiac output and decrease of venous oxygen saturation to depend on the ratio of pump twin to acardiac twin umbilical blood flow, whose ratio can be measured by ultrasonography. The clinical cases show a decreasing umbilical flow ratio with gestation. In conclusion, prospective serial study is necessary to test whether measurement of umbilical flow ratios allows monitoring the pump twin's pathophysiologic development, possibly resulting in a guideline for prognosis of pump twin survival. (note)

  1. Ranolazine and late cardiac sodium current – a therapeutic target for angina, arrhythmia and more?

    OpenAIRE

    Makielski, Jonathan C.; Valdivia, Carmen R.

    2006-01-01

    Ranolazine is a new antianginal drug approved for clinical use in the United States in January 2006. A study published in this same issue of the British Journal of Pharmacology characterizes ranolazine block of late sodium current caused by the long QT syndrome 3 mutations. This commentary discusses the implications of that study and the background and implications for block of late cardiac sodium current in general.

  2. Development of active magnetic bearings and ferrofluid seals toward oil free sodium pumps

    Energy Technology Data Exchange (ETDEWEB)

    Sreedhar, B.K., E-mail: bksd@igcar.gov.in; Kumar, R. Nirmal; Sharma, Prashant; Ruhela, Shivprakash; Philip, John; Sundarraj, S.I.; Chakraborty, N.; Mohana, M.; Sharma, Vijay; Padmakumar, G.; Nashine, B.K.; Rajan, K.K.

    2013-12-15

    Sodium centrifugal pumps employ conventional oil cooled bearings and mechanical seals to support the rotor assembly outside sodium and to seal the cover gas from the atmosphere. Although engineered safety features are incorporated in the design and detailed operational procedures formulated to ensure that no oil contamination of sodium can occur, there have been incidents of oil ingress into sodium. A design variant that eliminates the need for oil in top bearings and seals is therefore a promising option. This paper discusses the work in progress to develop a magnetic bearing and ferrofluid seal combination that can achieve this purpose.

  3. Development of active magnetic bearings and ferrofluid seals toward oil free sodium pumps

    International Nuclear Information System (INIS)

    Sodium centrifugal pumps employ conventional oil cooled bearings and mechanical seals to support the rotor assembly outside sodium and to seal the cover gas from the atmosphere. Although engineered safety features are incorporated in the design and detailed operational procedures formulated to ensure that no oil contamination of sodium can occur, there have been incidents of oil ingress into sodium. A design variant that eliminates the need for oil in top bearings and seals is therefore a promising option. This paper discusses the work in progress to develop a magnetic bearing and ferrofluid seal combination that can achieve this purpose

  4. Development of 160 m3/min large capacity sodium-immersed self-cooled electromagnetic pump

    International Nuclear Information System (INIS)

    A large capacity sodium-immersed self-cooled electromagnetic pump (LEMP) was developed for application to the main circulation pumps of FBR. This advanced LEMP is a submergible annular linear induction pump designed to be self-cooled by immersing into sodium and applying high temperature electrical insulation. Almost all the internal electrical losses were transferred to the surrounding sodium, which can be recovered as electricity by turbine generators. The LEPM having specifications of 160m3/min flow rate, 0.28 MPa head and more than 40% efficiency at the rating was designed, fabricated and tested in the sodium pump test facility. The test involves magnetic field measurement in the air and a variety of sodium tests during 2.550h, which demonstrated good pump performance and flow controllability, and satisfied the design target. The boundary between flow stability and instability of the LEMP operation could be defined by peak position of the Q-H curve, which was specified by Rem x S (magnetic Reynolds' number times slip) of 1.4 to 1.5 at 335degC. Based on the test results, the applicability of the LEMP for the FBR was confirmed. (author)

  5. Minimizing unbalance response of the CRBRP sodium pumps

    International Nuclear Information System (INIS)

    The unbalance response characteristics of the vertical pumps for the Clinch River Breeder Reactor Plant are investigated. Finite-element shell and beam models representative of the pump-motor structure including the rotating assembly are developed to assess structural stiffnesses of dominant joints as well as the foundation support stiffness so as to exclude the danger of resonant excitation during normal operation. Less than four mils peak-to-peak vibration amplitude at the pump tank discharge nozzle results from just 10% frequency separation between the first rocking mode and the maximum operating speed of 1116 RPM, based on 0.5% modal damping ratio and balance quality grade of ISO/ANSI G2.5 for the rotating components: motor rotor, pump shaft, Bendix diaphragm-type flexible coupling, and centrigual double-suction impeller. Several design options are explored for raising shaft critical speed beyond 125% of maximum operating speed

  6. Voltage clamp of the cardiac sodium current at 37 degrees C in physiologic solutions.

    OpenAIRE

    Murray, K T; Anno, T.; Bennett, P B; Hondeghem, L M

    1990-01-01

    The cardiac sodium current was studied in guinea pig ventricular myocytes using the cell-attached patch voltage clamp at 37 degrees C in the presence of 145 mM external sodium concentration. When using large patch pipettes (access resistance, 1-2 M omega), the capacity current transient duration was typically 70 microseconds for voltage clamp steps up to 150 mV. At 37 degrees C the maximum inward sodium current peaked in approximately 200 microseconds after the onset of a clamp step and at th...

  7. Structure of the light-driven sodium pump KR2 and its implications for optogenetics.

    Science.gov (United States)

    Gushchin, Ivan; Shevchenko, Vitaly; Polovinkin, Vitaly; Borshchevskiy, Valentin; Buslaev, Pavel; Bamberg, Ernst; Gordeliy, Valentin

    2016-04-01

    A key and common process present in organisms from all domains of life is the maintenance of the ion gradient between the inside and the outside of the cell. The gradient is generated by various active transporters, among which are the light-driven ion pumps of the microbial rhodopsin family. Whereas the proton-pumping and anion-pumping rhodopsins have been known for a long time, the cation (sodium) pumps were described only recently. Following the discovery, high-resolution atomic structures of the pump KR2 were determined that revealed the complete ion translocation pathway, including the positions of the characteristic Asn-Asp-Gln (NDQ) triad, the unusual ion uptake cavity acting as a selectivity filter, the unique N-terminal α-helix, capping the ion release cavity, and unexpected flexibility of the retinal-binding pocket. The structures also revealed pentamerization of KR2 and binding of sodium ions at the interface. Finally, on the basis of the structures, potassium-pumping KR2 variants have been designed, making the findings even more important for optogenetic applications. In this Structural Snapshot, we analyse the implications of the structural findings for understanding the sodium translocation mechanism and application of the pump and its mutants in optogenetics. PMID:26535564

  8. Molecular basis for class Ib anti-arrhythmic inhibition of cardiac sodium channels

    DEFF Research Database (Denmark)

    Pless, Stephan Alexander; Galpin, Jason D; Frankel, Adam; Ahern, Christopher A

    2011-01-01

    Cardiac sodium channels are established therapeutic targets for the management of inherited and acquired arrhythmias by class I anti-arrhythmic drugs (AADs). These drugs share a common target receptor bearing two highly conserved aromatic side chains, and are subdivided by the Vaughan-Williams cl...

  9. Phenotypical Manifestations of Mutations in the Genes Encoding Subunits of the Cardiac Sodium Channel

    NARCIS (Netherlands)

    Wilde, Arthur A. M.; Brugada, Ramon

    2011-01-01

    Variations in the gene encoding for the major sodium channel (Na(v)1.5) in the heart, SCN5A, has been shown to cause a number of arrhythmia syndromes (with or without structural changes in the myocardium), including the long-QT syndrome (type 3), Brugada syndrome, (progressive) cardiac conduction di

  10. Quantitative modelling of interaction of propafenone with sodium channels in cardiac cells

    Czech Academy of Sciences Publication Activity Database

    Pásek, Michal; Šimurda, J.

    2004-01-01

    Roč. 42, č. 2 (2004), s. 151-157. ISSN 0140-0118 R&D Projects: GA ČR GP204/02/D129 Institutional research plan: CEZ:AV0Z2076919 Keywords : cardiac cell * sodium current block * quantitative modelling Subject RIV: BO - Biophysics Impact factor: 1.070, year: 2004

  11. Rotor dynamic studies of a vertical sodium pump supported on a spherical seat

    International Nuclear Information System (INIS)

    One of the important areas in the mechanical design of Primary Sodium Pumps (PSP) concerns with the problem of accommodating the differential thermal expansion between the pump support and the discharge pipe which function at substantially different temperatures. A spherical ball resting on a spherical split seat is designed to allow the tilting of the pump without creating significant stresses in the pump casing and the discharge pipe. To ascertain the dynamic performance of the pump and to validate the design, an experimental study was carried out with a 1/4 model spherical seat installed in an existing 50 cu.m/hr pump. The paper discusses the modeling criteria, details of theoretical/experimental studies and results obtained during testing. This paper also discusses details of full size test rig which is under construction. (author). 4 refs., 3 figs., 2 tabs

  12. Temporal Analysis of Valence & Electrostatics in Ion-Motive Sodium Pump

    OpenAIRE

    J. Fonseca; Kaya, S.; Guennoun, S.; Rakowski, R.

    2007-01-01

    The present work establishes a unique framework for the simulation study of ion-motive pumps in general and the Na+/K+-ATPase, or sodium pump, in particular. We shall discuss the implications of electrostatic analysis, valence calculations, and protein cavity data, each carried over data extracted from molecular dynamics simulations, on the structure-function relationship of Na+/K+-ATPase. These diverse set of tools will be used to investigate atomic-level characteristics that remain undeterm...

  13. Activities of cavitation studies and R and D works of sodium pumps in Japan

    International Nuclear Information System (INIS)

    PNC is now performing design studies of large FBR, making the best use of past experiences from JOYO, MONJU and related R and Ds, aiming at future effective and sound development of FBR technology and at the appropriate cooperation with utilities and manufacturers. In this paper the activities of cavitation studies and R and D works of sodium pumps as well as general review of the FBR development are presented. Such activities are concentrated on the following items: 1) In-sodium and in-water cavitation tests of JOYO primary and secondary pumps as well as cavitation damage inspection after 30,000 hours of operation. 2) In-water cavitation test of subscale mock-up pumps (1/2-1/3) for MONJU. 3) In-water cavitation test of subscale mock-up pump (1/2.5) for large FBR including incipient cavitation bubble observation. 4) Cavitation tests of FLIPs (600 2/min and 1100 1/min) and ALIP (400 1/min). 5) Approach to define more advanced cavitation criteria for electromagnetic pumps instead of applying Thoma's dimensionless parameter. In view of this, cavitation tests of a FLIP and its duct models with sodium and model fluid are conducted. 6) Studies on the impeller type optimization for large FBRs: Single suction, double suction and inducer type are comprised. 7) Design studies of single suction and double suction pumps for large FBRs. (author)

  14. Minimizing unbalance response of the CRBRP sodium pumps

    International Nuclear Information System (INIS)

    The unbalance response characteristics of the vertical pumps for the Clinch River Breeder Reactor Plant are investigated. Finite-element shell and beam models representative of the pump-motor structure including the rotating assembly are developed to assess structural stiffnesses of dominant joints as well as the foundation support stiffness so as to exclude the danger of resonant excitation during normal operation. Less than four mils peak-to-peak vibration amplitude at the pump tank discharge nozzle results from just 10% frequency separation between the first rocking mode and the maximum operating speed of 1116 RPM, based on 0.5% modal damping ratio and balance quality grade of ISO/ANSI G2.5 for the rotating components: motor rotor, pump shaft, Bendix diaphragm-type flexible coupling, and centrifugal double-suction impeller. Several design options are explored for raising shaft critical speed beyond 125% of maximum operating speed. NASTRAN complex eigenvalue solution is performed to take credit for damping in bearings to help meet this requirement. The mitigating effect of increasing shaft critical speed on both unbalance response and seismic response is evaluated. The influence of horizontal foundation stiffness on shaft whip is demonstrated, apart from staggering lateral modes in an effort to minimize dynamic coupling between them; higher the stiffness, less the shaft whip expressed as the peak lateral response along the vertical shaft. Parametric curves are presented illustrating the extent to which the fundamental rocking mode frequency is influenced by the combined rotational stiffness of the pump foundation and closure flange assembly. The fundamental rocking mode is raised high enough to become less sensitive to the foundation stiffness. (orig.)

  15. Use of Sodium Bicarbonate in Cardiac Arrest: Current Guidelines and Literature Review.

    Science.gov (United States)

    Velissaris, Dimitrios; Karamouzos, Vassilios; Pierrakos, Charalampos; Koniari, Ioanna; Apostolopoulou, Christina; Karanikolas, Menelaos

    2016-04-01

    The aim of the review was to summarize the literature over the last 25 years regarding bicarbonate administration in out-of-hospital cardiac arrest. A PubMed search was conducted using the terms "bicarbonates" and "cardiac arrest", limited to human studies and reviews published in English (or at least with a meaningful abstract in English) in the last 25 years. Clinical and experimental data raised questions regarding the safety and effectiveness of sodium bicarbonate (SB) administration during cardiac arrest. Earlier advanced cardiac life support (ACLS) guidelines recommended routine bicarbonate administration as part of the ACLS algorithm, but recent guidelines no longer recommend its use. The debate in the literature is ongoing, but at the present time, SB administration is only recommended for cardiac arrest related to hypokalemia or overdose of tricyclic antidepressants. Several studies challenge the assumption that bicarbonate administration is beneficial for treatment of acidosis in cardiac arrest. At the present time, there is a trend against using bicarbonates in cardiac arrest, and this trend is supported by guidelines published by professional societies and organizations. PMID:26985247

  16. Cardiac Repolarization Abnormalities and Potential Evidence for Loss of Cardiac Sodium Currents on ECGs of Patients with Chagas' Heart Disease

    Science.gov (United States)

    Schlegel, T. T.; Medina, R.; Jugo, D.; Nunez, T. J.; Borrego, A.; Arellano, E.; Arenare, B.; DePalma, J. L.; Greco, E. C.; Starc, V.

    2007-01-01

    Some individuals with Chagas disease develop right precordial lead ST segment elevation in response to an ajmaline challenge test, and the prevalence of right bundle branch block (RBBB) is also high in Chagas disease. Because these same electrocardiographic abnormalities occur in the Brugada syndrome, which involves genetically defective cardiac sodium channels, acquired damage to cardiac sodium channels may also occur in Chagas disease. We studied several conventional and advanced resting 12-lead/derived Frank-lead ECG parameters in 34 patients with Chagas -related heart disease (mean age 39 14 years) and in 34 age-/gender-matched healthy controls. All ECG recordings were of 5-10 min duration, obtained in the supine position using high fidelity hardware/software (CardioSoft, Houston, TX). Even after excluding those Chagas patients who had resting BBBs, tachycardia and/or pathologic arrhythmia (n=8), significant differences remained in multiple conventional and advanced ECG parameters between the Chagas and control groups (n=26/group), especially in their respective QT interval variability indices, maximal spatial QRS-T angles and low frequency HRV powers (p=0.0006, p=0.0015 and p=0.0314 respectively). In relation to the issue of potential damage to cardiac sodium channels, the Chagas patients had: 1) greater than or equal to twice the incidence of resting ST segment elevation in leads V1-V3 (n=10/26 vs. n=5/26) and of both leftward (n=5/26 versus n=0/26) and rightward (n=7/26 versus n=3/26) QRS axis deviation than controls; 2) significantly increased filtered (40-250 Hz) QRS interval durations (92.1 8.5 versus 85.3 plus or minus 9.0 ms, p=0.022) versus controls; and 3) significantly decreased QT and especially JT interval durations versus controls (QT interval: 387.5 plus or minus 26.4 versus 408.9 plus or minus 34.6 ms, p=0.013; JT interval: 290.5 plus or minus 26.3 versus 314.8 plus or minus 31.3 ms; p=0.0029). Heart rates and Bazett-corrected QTc/JTc intervals

  17. Two functionally different Na/K pumps in cardiac ventricular myocytes

    OpenAIRE

    1995-01-01

    The whole-cell patch-clamp technique was used to voltage clamp acutely isolated myocytes at -60 mV and study effects of ionic environment on Na/K pump activity. In quiescent guinea pig myocytes, normal intracellular Na+ is approximately 6 mM, which gives a total pump current of 0.25 +/- 0.09 pA/pF, and an inward background sodium current of 0.75 +/- 0.26 pA/pF. The average capacitance of a cell is 189 +/- 61 pF. Our main conclusion is the total Na/K pump current comprises currents from two di...

  18. Cavitation erosion scaling: tests on a pump impeller in water and in sodium

    International Nuclear Information System (INIS)

    Tests to quantify cavitation agressivity carried out in water and in sodium (400 deg) on a model pump impeller are presented. The polished samples method has been used. It can be now applied to curved surfaces such as impeller blades with the help of new measurement devices. Results are discussed regarding scaling laws for fluid-to-fluid transposition

  19. Sodium pump molecular activity and membrane lipid composition in two disparate ectotherms, and comparison with endotherms.

    Science.gov (United States)

    Turner, Nigel; Hulbert, A J; Else, Paul L

    2005-02-01

    Previous research has shown that the lower sodium pump molecular activity observed in tissues of ectotherms compared to endotherms, is largely related to the lower levels of polyunsaturates and higher levels of monounsaturates found in the cell membranes of ectotherms. Marine-based ectotherms, however, have very polyunsaturated membranes, and in the current study, we measured molecular activity and membrane lipid composition in tissues of two disparate ectothermic species, the octopus (Octopus vulgaris) and the bearded dragon lizard (Pogona vitticeps), to determine whether the high level of membrane polyunsaturation generally observed in marine-based ectotherms is associated with an increased sodium pump molecular activity relative to other ectotherms. Phospholipids from all tissues of the octopus were highly polyunsaturated and contained high concentrations of the omega-3 polyunsaturate, docosahexaenoic acid (22:6 (n-3)). In contrast, phospholipids from bearded dragon tissues contained higher proportions of monounsaturates and lower proportions of polyunsaturates. Sodium pump molecular activity was only moderately elevated in tissues of the octopus compared to the bearded dragon, despite the much greater level of polyunsaturation in octopus membranes. When the current data were combined with data for the ectothermic cane toad, a significant (P = 0.003) correlation was observed between sodium pump molecular activity and the content of 22:6 (n-3) in the surrounding membrane. These results are discussed in relation to recent work which shows a similar relationship in endotherms. PMID:15726386

  20. Flavonolignans as a Novel Class of Sodium Pump Inhibitors

    Directory of Open Access Journals (Sweden)

    Martin eKubala

    2016-03-01

    Full Text Available We examined the inhibitory effects of three flavonolignans and their dehydro- derivatives, taxifolin and quercetin on the activity of the Na+/K+-ATPase (NKA. The flavonolignans silychristin, dehydrosilychristin and dehydrosilydianin inhibited NKA with IC50 of 110 ± 40 μM, 38 ± 8 µM and 36 ± 14 µM, respectively. Using the methods of molecular modeling, we identified several possible binding sites for these species on NKA and proposed the possible mechanisms of inhibition. The binding to the extracellular- or cytoplasmic C-terminal sites can block the transport of cations through the plasma membrane, while the binding on the interface of cytoplasmic domains can inhibit the enzyme allosterically. Fluorescence spectroscopy experiments confirmed the interaction of these three species with the large cytoplasmic segment connecting transmembrane helices 4 and 5 (C45. The flavonolignans are distinct from the cardiac glycosides that are currently used in NKA treatment. Because their binding sites are different, the mechanism of inhibition is different as well as the range of active concentrations, one can expect that these new NKA inhibitors would exhibit also a different biomedical actions than cardiac glycosides.

  1. Thyrotoxic periodic paralysis and the sodium/potassium pump.

    Science.gov (United States)

    Marx, A; Ruppersberg, J P; Pietrzyk, C; Rüdel, R

    1989-10-01

    The hypothesis of altered Na+/K+ transport in thyrotoxic periodic paralysis (TPP) was tested in an investigation of the K+ influx into erythrocytes from two patients with episodes of thyrotoxic muscle weakness. A patient with primary hypokalemic periodic paralysis (HPP) and three healthy volunteers served as controls. The TPP patients were of Oriental and Caucasian origin and differed in their clinical symptoms. For the Caucasian patient, the Na+ content of the erythrocytes was twice the control, for the Oriental patient it was normal. The K+ dependence of the ouabain-inhibitable K+ influx (the pump action) was also abnormal in the Caucasian patient, the flux being 70% of control at 2 mM [K+]e and normal at 4 mM [K+]e. The K+ influx was normal in the Oriental patient. By contrast, the K+ leak of the cells was normal in the Caucasian and was increased in the Oriental patient. The pump/leak ratio was thus reduced in both TPP patients. All parameters investigated were normal in the patient with primary HPP. It is concluded that the ion transport systems of muscle may be altered in TPP, but that the patho-mechanism might be different in the rare Caucasian cases and the rather more common Oriental cases. PMID:2558311

  2. Characterization and influence of cardiac background sodium current in the atrioventricular node

    OpenAIRE

    Cheng, Hongwei; Li, Jue; James, Andrew F.; Inada, Shin; Choisy, Stéphanie C.M.; Orchard, Clive H.; Zhang, Henggui; Boyett, Mark R.; Hancox, Jules C.

    2016-01-01

    Background inward sodium current (IB,Na) that influences cardiac pacemaking has been comparatively under-investigated. The aim of this study was to determine for the first time the properties and role of IB,Na in cells from the heart's secondary pacemaker, the atrioventricular node (AVN). Myocytes were isolated from the AVN of adult male rabbits and mice using mechanical and enzymatic dispersion. Background current was measured using whole-cell patch clamp and monovalent ion substitution with...

  3. Resonant photopumping of a neon lasant plasma by a sodium pump plasma

    International Nuclear Information System (INIS)

    Resonant photopumping of heliumlike neon by helium like sodium is being investigated to extend this pumping technique to the soft x-ray region. In the Na-pump/Ne-lasant system, the 1s2-1s2p1P1 line of Na X at 11.0027 A differs by 2 parts in 104 from the 1s2-1s4p1P1 line of Ne 1X at 11.0003 A. This wavelength difference corresponds to about one Doppler width at the sodium plasma temperatures (200-500 eV) required for strong Na X pump radiation. Sodium line radiation of sufficient power irradiating a properly prepared neon plasma will cause overpopulation of the Ne 1X n = 4 singlet level leading to lasing in the 4-3, 4-2, and possibly 3-2 singlet transitions. Experimentally, the current pulse from the NRL Gamble-II generator is used to produce side-by-side z-pinch plasmas of sodium fluoride (NaF) and neon. The discharges are viewed radially with x-ray diagnostics including time-integrated pinhole cameras, time-resolved x-ray diodes, and a time-integrated curved-crystal spectrograph. Measurements of the neon plasma indicate that a discharge current of about 200 kA is required to produce a neon lasant with a dominant heliumlike ground-state population. For fluorescence experiments, appropriate neon lasant conditions (density of about 1018 cm-3 and temperature of 50-100 eV) must be produced at the time of the intense sodium pump-line radiation. Fluorescence is demonstrated by observing enhancement of the 4-1 line (He-γ) from the neon plasma relative to the 3-1 line (He-γ) when the neon is pumped by sodium. An increase in this γ-to-β ratio of 25% has been observed when the sodium pump radiation is present. The results of recent experiments are reported, and their implications for future experiments are discussed

  4. Internal fluid flow management analysis for Clinch River Breeder Reactor Plant sodium pumps

    International Nuclear Information System (INIS)

    The Clinch River Breeder Reactor Plant (CRBRP) sodium pumps are currently being designed and the prototype unit is being fabricated. In the design of these large-scale pumps for elevated temperature Liquid Metal Fast Breeder Reactor (LMFBR) service, one major design consideration is the response of the critical parts to severe thermal transients. A detailed internal fluid flow distribution analysis has been performed using a computer code HAFMAT, which solves a network of fluid flow paths. The results of the analytical approach are then compared to the test data obtained on a half-scale pump model which was tested in water. The details are presented of pump internal hydraulic analysis, and test and evaluation of the half-scale model test results

  5. The specific case: cardiac amyloidosis as differential diagnosis in case of restricted cardiac pump function

    International Nuclear Information System (INIS)

    The NMR imaging data in combination with clinical characterization and echocardiography are consistent with the diagnosis of a cardiac amyloidosis. The article describes disease pattern and diagnosis based on contrast agent accumulation and diastolic functional disturbances. CT was performed to exclude pulmonary embolism.

  6. Sodium nuclear magnetic resonance imaging of acute cardiac rejection in heterotopic heart transplantation

    International Nuclear Information System (INIS)

    Nuclear magnetic resonance (NMR) imagings have been applied to the observation of tissue sodium-23 in myocardium undergoing cardiac rejection. Six canine donor hearts were heterotopically transplanted in the recipient's chest cavity. The dogs were then killed and sodium-23 image of the excised donor hearts were obtained using a high field NMR imaging system (1.5 Tesla, Magnetom). Proton NMR imaging was also performed and T1, T2 relaxation times were calculated. Subsequently, these data were correlated with pathologic findings such as mild, moderate and severe rejection. The correlation coefficients between rejection score, and T1, T2 times and sodium NMR signal intensity were 0.79, 0.70 and 0.80, respectively. The moderate or severe rejected myocardium were clearly visible as areas of increased sodium NMR signal. These data suggested that increase of sodium may be mainly caused by the myocardial cellular necrosis. Sodium NMR will allow us to evaluate the location and extent of rejected myocardium undergoing heart transplantation. (author)

  7. An analysis of the energetic cost of the branchial and cardiac pumps during sustained swimming in trout

    DEFF Research Database (Denmark)

    FARRELL, AP; STEFFENSEN, JF

    1987-01-01

    the relative oxygen cost of the cardiac pumps decreased from 4.6% at rest to 1.9% at the critical swimming speed. The relative oxygen cost of the branchial pump is significant in the resting and slowly swimming fish, being 10 to 15% of total oxygen uptake. However, when swimming trout switch to a ram mode...... of ventilation, a considerable saving in oxygen cost is accrued by switching the cost of ventilation from the branchial to the tail musculature. Thus, the relative oxygen cost of the branchial and cardiac pumps actually decreases at critical swimming speed compared to rest and therefore is unlikely to be a major......Experimental data are available for the oxygen cost of the branchial and cardiac pumps in fish. These data were used to theoretically analyze the relative oxygen cost of these pumps during rest and swimming in rainbow troutSalmo gairdneri. Efficiency of the heart increases with activity and so...

  8. Mass transfer of stainless steel in pumped sodium loops and its effect on microstructure

    International Nuclear Information System (INIS)

    Metallography and supporting analytical techniques have been used to study the corrosion and deposition behaviour of steel material in two pumped figure-of-eight loops operating at oxygen levels of 10 and 25 ppm. Corrosion has been identified in the high temperature parts of the system and ferrite layer formation and the undercutting of steel surfaces through the formation of sodium chromite have been established in the maximum temperature and downstream positions respectively. The damaged surface layer consists of Fe-Ni particles which after removal by the flowing sodium deposit in the low temperature part of the loop. (orig.)

  9. The replacement of an electromagnetic primary sodium sampling pump in the Fast Flux Test Facility

    International Nuclear Information System (INIS)

    On November 16, 1984 a leak was discovered in one of the Fast Flux Test Facility (FFTF) Primary Sodium Sampling System electromagnetic pumps. The leak was discovered in the course of routine cell entry to investigate a shorted trace heat element. The purpose of this paper is to describe the circumstances surrounding the occurrence of the leak, the actions taken to replace the damaged pump and the additional steps which were necessary to return the plant to power. In addition, the processes involved in producing the leak are described briefly. The relative ease of recovery from this incident is indicative of the overall feasibility of the Liquid Metal Reactor (LMR) operational concept

  10. Temporal Analysis of Valence & Electrostatics in Ion-Motive Sodium Pump.

    Science.gov (United States)

    Fonseca, J; Kaya, S; Guennoun, S; Rakowski, R

    2007-09-01

    The present work establishes a unique framework for the simulation study of ion-motive pumps in general and the Na(+)/K(+)-ATPase, or sodium pump, in particular. We shall discuss the implications of electrostatic analysis, valence calculations, and protein cavity data, each carried over data extracted from molecular dynamics simulations, on the structure-function relationship of Na(+)/K(+)-ATPase. These diverse set of tools will be used to investigate atomic-level characteristics that remain undetermined such as ion binding and accessibility. PMID:18769504

  11. Thallium and the sodium pump in human red cells.

    Science.gov (United States)

    Cavieres, J D; Ellory, J C

    1974-11-01

    1. Thallium (Tl) inhibits the ouabain-sensitive K influx in human red cells in high-Na medium. At 1 mM external K concentration [K(o)], the ouabain-sensitive K influx decreases steadily with increasing Tl concentration, up to 0.9 mM outside; at 0.17 mM-K(o), however, Tl stimulates the ouabain-sensitive K influx below 0.1 mM-Tl(o) and inhibits it at higher concentrations.2. In a K-free medium in which all except 5 mM-Na is replaced by choline, and into which red cells show zero control ouabain-sensitive Na efflux, Tl is able to support ouabain-sensitive Na efflux up to 2.1 m-mole/l. cells.hr following a sigmoid activation curve which is half-maximal between 0.03 and 0.05 mM-Tl(o) and that follows two-site kinetics up to 0.1 mM-Tl(o). Beyond 0.15 mM-Tl(o), the Tl-activated ouabain-sensitive Na efflux attained is inhibited slightly.3. When the ouabain-sensitive Na efflux is measured at 5 mM-Na(o) and 5 mM-K(o), increasing concentrations of Tl have little effect on it, 0.9 mM-Tl(o) inhibiting by some 14%; in similar conditions, the ouabain-sensitive K influx is inhibited by about 40%.4. The dependence of ouabain-sensitive K influx on external K concentration at 5 mM-Na(o), which follows a slightly sigmoid curve in the absence of Tl, changes to hyperbolic at 0.06 mM-Tl(o) at the same time that ouabain-sensitive K influx is inhibited. The fitted V(max) values for ouabain-sensitive K influx are the same in the presence and in the absence of 0.06 mM-Tl(o).5. In high-Na cells, loaded by nystatin treatment, the ouabain-sensitive K influx measured at 0.2 mM-Na(o) follows a hyperbolic curve between 0.05 and 0.4 mM-K(o), and is inhibited by Tl in a strictly competitive fashion.6. The effects of Tl on ouabain-sensitive Na efflux and ouabain-sensitive K influx are interpreted in terms of a high-affinity substitution for K at the external K sites of the Na pump and suggest that in human red cells Tl can be actively transported inwards in exchange for internal Na.7. Thallium can

  12. Large electro-magnetic pump design for application in the ASTRID sodium-cooled fast reactor

    International Nuclear Information System (INIS)

    Within the framework of the French SFR prototype called ASTRID (Advanced Sodium Technological Reactor for Industrial Demonstration) aiming at demonstrating the progress made in Sodium Fast Reactor (SFR) technology on an industrial scale, it is foreseen to implement Large capacity Electro-Magnetic Pumps (LEMP) in place of mechanical pumps on the intermediate sodium circuits. The use of LEMPs is justified by several advantages in the reactor design, operation and maintenance. Due to the specific operating conditions, an annular linear induction pump (ALIP) type is the most promising technology for such an application. Nevertheless, some theoretical and technological developments have to be carried out in order to validate the design tools by taking into account Magneto Hydro Dynamic (MHD) phenomena and the applicability of the LEMP to ASTRID steady state and transient operating conditions. In this aim, a collaboration agreement between the CEA and TOSHIBA Corporation came into force in April 2012 to carry out a joint work program on the ASTRID EMP design and development. This paper discusses the dedicated design studies and experimental activities for the LEMP development within the framework of the CEA-TOSHIBA collaboration. (author)

  13. Oxygen uptake occurs faster than sodium pumping in bee retina after a light flash.

    Science.gov (United States)

    Tsacopoulos, M; Orkand, R K; Coles, J A; Levy, S; Poitry, S

    When neurones are active there is an entry of Na+, which must subsequently be pumped out, and an increase in their oxygen consumption rate (Qo2). The Na+ pump derives its energy from ATP, splitting it into ADP and Pi, and it has reasonably been proposed that the changes in concentrations of ATP, ADP and Pi lead to a stimulation of the O2 consumption by the mitochondria and hence to a restoration of the stock of ATP. Here we present evidence suggesting that Qo2 must be controlled differently in the retinal photoreceptor cells of the honeybee drone. Stimulation of drone photoreceptors with a flash of light causes an entry of Na+ (ref. 4) and a transient increase in Qo2 that indicates respiration of the right order of magnitude to provide ATP to pump the Na+ out. We report intracellular recordings of changes in intracellular sodium (Nai+) and potassium (Ki+) in response to single light flashes and have compared the time course of extra oxygen consumption (delta Qo2) with these ion changes and other indices of Na+ pumping. We found that the time course of pumping seems to lag behind the time course of delta Qo2. It follows that the mitochondrial respiration must be stimulated by some signal which is generated earlier than the rise in ADP produced by the Na+ pump. PMID:6828139

  14. Seismic analysis of primary sodium pump of prototype fast breeder reactor

    International Nuclear Information System (INIS)

    This paper deals with seismic analysis of primary sodium pump of 500 MWe Prototype Fast Breeder Reactor (PFBR) by time history analysis. The associated fluid mechanics equations for determining stiffness coefficients for hydrostatic bearing (HSB) are formulated and solved by integrating with the governing structural dynamics equations. Thus, the stiffness coefficients of HSB are computed as function of eccentricity, speed and angular orientation of shaft at every solution time step. The maximum stress intensity values in the flywheel-motor support shell, pump shell and shaft are insignificant (<20 MPa). Hence, the structural integrity is assured for pump parts. The seizure of pump is found to be a critical issue under seismic events. The eccentricity of 60 μ experienced by the shaft during normal operation, increases to 250 μ under SSE. Since it is < 400 μ, the radial clearance, there is no problem of pump seizure. However, at speeds lower than 265 rpm, the eccentricity of shaft is higher than radial clearance and hence shaft can impact on the shell. Under OBE, up to 20 % speed (∼120 rpm), there is no impact. The peak impact force experienced by shaft and shell at HSB at 235 rpm under SSE is < 3 t, which may not cause pump seizure. This needs to be confirmed by experiments. (author)

  15. Leakage of pump bearing oil into the PFR primary sodium, June 1991

    International Nuclear Information System (INIS)

    During the period 25-29 June 1991 a total of 35 l of lubricating oil from the bearing of one of the PFR primary pumps leaked into the primary sodium. The cause was a depressurization of the oil drains tank. Overheating of the affected bearing was observed, and the reactor was tripped manually. The main consequences of the event were contamination of the sodium, partial blockage of the pump outlet filters, and small increases in the outlet temperatures from some of the fuel subassemblies. Contamination of the sodium was removed by operation of the primary cold trap without difficulty. During 1992 the three filter assemblies were removed from the reactor and examined. They were found to be partly blocked with deposits incorporating carbon. The filter panels were replaced, and the assemblies restored to the reactor. Examination of a number of fuel assemblies showed deposits on the inlet filters of those which had exhibited temperature increases prior to shutdown, but none on those which had not. There were also fine deposits on the surfaces of some of the fuel pins. There was no evidence of any damage to the fuel. Experiments were conducted to demonstrate that the coolant flow rate through the remaining subassemblies was acceptable. Tests in a Russian experimental rig clarified certain important aspects of the behaviour of oil in sodium. As a result of this and other work permission was given by the safety authorities, and the reactor was restarted at the end of December 1992. (author)

  16. A Common Polymorphism of the Human Cardiac Sodium Channel Alpha Subunit (SCN5A) Gene Is Associated with Sudden Cardiac Death in Chronic Ischemic Heart Disease

    Science.gov (United States)

    Marcsa, Boglárka; Dénes, Réka; Vörös, Krisztina; Rácz, Gergely; Sasvári-Székely, Mária; Rónai, Zsolt; Törő, Klára; Keszler, Gergely

    2015-01-01

    Cardiac death remains one of the leading causes of mortality worldwide. Recent research has shed light on pathophysiological mechanisms underlying cardiac death, and several genetic variants in novel candidate genes have been identified as risk factors. However, the vast majority of studies performed so far investigated genetic associations with specific forms of cardiac death only (sudden, arrhythmogenic, ischemic etc.). The aim of the present investigation was to find a genetic marker that can be used as a general, powerful predictor of cardiac death risk. To this end, a case-control association study was performed on a heterogeneous cohort of cardiac death victims (n=360) and age-matched controls (n=300). Five single nucleotide polymorphisms (SNPs) from five candidate genes (beta2 adrenergic receptor, nitric oxide synthase 1 adaptor protein, ryanodine receptor 2, sodium channel type V alpha subunit and transforming growth factor-beta receptor 2) that had previously been shown to associate with certain forms of cardiac death were genotyped using sequence-specific real-time PCR probes. Logistic regression analysis revealed that the CC genotype of the rs11720524 polymorphism in the SCN5A gene encoding a subunit of the cardiac voltage-gated sodium channel occurred more frequently in the highly heterogeneous cardiac death cohort compared to the control population (p=0.019, odds ratio: 1.351). A detailed subgroup analysis uncovered that this effect was due to an association of this variant with cardiac death in chronic ischemic heart disease (p=0.012, odds ratio = 1.455). None of the other investigated polymorphisms showed association with cardiac death in this context. In conclusion, our results shed light on the role of this non-coding polymorphism in cardiac death in ischemic cardiomyopathy. Functional studies are needed to explore the pathophysiological background of this association. PMID:26146998

  17. Characterization and isolation of a light driven sodium pump from membranes of Halobacterium halobium. Final technical progress report

    International Nuclear Information System (INIS)

    We investigated three aspects of the light driven sodium pump (halorhodopsin, which appear to be crucial to our understanding of the mechanisms employed by Halobacterium halobium and to further investigate this unique system of energy conservation. We characterized the molecular mechanisms of transmembrane sodium transport in vesicles from H. halobium with particular reference to the mechanism of couplins of light energy to net sodium translocation. We develop procedures and techniques for extracting the components of the light driven sodium pump from membranes and incorporating them into artificial membrane systems. We examine the mechanism of conversion of bacteriorhodopsin from an active to an inactive form in membrane vesicles and to relate this alternative state of this pigment to the presence of the light driven sodium pump

  18. Are extracellular osmolality and sodium concentration determined by Donnan effects of intracellular protein charges and of pumped sodium?

    Science.gov (United States)

    Kurbel, Sven

    2008-06-21

    Although we are used to attribute almost identical extracellular fluid (ECF) sodium concentrations in birds, amphibians, reptiles, and mammals to the composition of the primordial oceans in which, presumably, all life originated, this interpretation is not supported by geological data suggesting that the ocean salinity was never much lower than the present-day values, still four times higher than our plasma sodium. Here presented interpretation is that the similar ECF salt concentrations are dictated by the opposed Donnan effects on the cell membrane. The only way for the cell to reach the osmotic equilibrium is to alter cell volume, until concentration of nondiffusible intracellular ions (mainly charges on intracellular proteins) is equal to the ECF restricted ions (mainly Na+ ions, restricted by pumping out of cells). The achievement of electroneutrality requires that the sum of all anions equals concentration of positive ions in the cell (mainly K+). Negative charges on cytoplasmic proteins are the most stable component among ionized particles and other ions have to adapt to their concentration. Positive and negative soluble intracellular ions are all osmotically active and to achieve balance of osmotic forces on the cell membrane, the sum of their intracellular concentrations must equal the concentration of osmotically active extracellular particles. Since almost half the osmotically active ECF particles are sodium ions, the ECF sodium concentration seems related to concentration of charges on cytoplasmic proteins and concentration of intracellular phosphates. Our ancestors could not leave the salty ocean and move to brackish, or even fresh waters, without adequate regulation of their ECF sodium concentration and osmolality. Concentration of charges on cytoplasmic proteins or of intracellular phosphate buffers could not be altered, since this would compromise cell functioning. The remaining solution was to maintain the lowest ECF Na+ concentration effective in

  19. Improved Outcome of Cardiac Extracorporeal Membrane Oxygenation in Infants and Children Using Magnetic Levitation Centrifugal Pumps.

    Science.gov (United States)

    Luciani, Giovanni Battista; Hoxha, Stiljan; Torre, Salvatore; Rungatscher, Alessio; Menon, Tiziano; Barozzi, Luca; Faggian, Giuseppe

    2016-01-01

    Extracorporeal membrane oxygenation (ECMO) has traditionally been and, for the most part, still is being performed using roller pumps. Use of first-generation centrifugal pumps has yielded controversial outcomes, perhaps due to mechanical properties of the same and the ensuing risk of hemolysis and renal morbidity. Latest-generation centrifugal pumps, using magnetic levitation (ML), exhibit mechanical properties which may have overcome limitations of first-generation devices. This retrospective study aimed to assess the safety and efficacy of veno-arterial (V-A) ECMO for cardiac indications in neonates, infants, and children, using standard (SP) and latest-generation ML centrifugal pumps. Between 2002 and 2014, 33 consecutive neonates, infants, and young children were supported using V-A ECMO for cardiac indications. There were 21 males and 12 females, with median age of 29 days (4 days-5 years) and a median body weight of 3.2 kg (1.9-18 kg). Indication for V-A ECMO were acute circulatory collapse in ICU or ward after cardiac repair in 16 (49%) patients, failure to wean after repair of complex congenital heart disease in 9 (27%), fulminant myocarditis in 4 (12%), preoperative sepsis in 2 (6%), and refractory tachy-arrhythmias in 2 (6%). Central cannulation was used in 27 (81%) patients and peripheral in 6. Seven (21%) patients were supported with SP and 26 (79%) with ML centrifugal pumps. Median duration of support was 82 h (range 24-672 h), with 26 (79%) patients weaned from support. Three patients required a second ECMO run but died on support. Seventeen (51%) patients required peritoneal dialysis for acute renal failure. Overall survival to discharge was 39% (13/33 patients). All patients with fulminant myocarditis and with refractory arrhythmias were weaned, and five (83%) survived, whereas no patient supported for sepsis survived. Risk factors for hospital mortality included lower (<2.5 kg) body weight (P = 0.02) and rescue ECMO after cardiac

  20. The interaction of monovalent cations with the sodium pump of low-potassium goat erythrocytes.

    Science.gov (United States)

    Cavieres, J D; Ellory, J C

    1977-09-01

    1. The activation by Na ions and the effect of the anti-L antibody on the sodium pump of low-potassium type (LK) erythrocytes, have been studied by measuring ouabain-sensitive ATPase activity of red cell membranes of LK goats. The experimental data were first corrected for incomplete occupation of the external K sites of the pump, using a saturation function obtained from influx experiments.2. Double-reciprocal plots of the corrected rates against Na concentration at various fixed K concentrations, yield a pattern of competitive K inhibition when it is assumed that three equivalent sodium sites take part in the internal activation of LK-(Na+K)-ATPase. The dissociation constant of Na at each site (K(m)) lies between 10 and 20 mM and that of K as competitive inhibitor (K(i)), between 1.5 and 4.5 mM.3. The maximal rate of hydrolysis of LK goat (Na + K)-ATPase is not different from those usually obtained with the high-potassium type (HK) red cell enzyme. Then, the low pumping rate of LK erythrocytes in physiological conditions is only reflecting the poor Na affinity, both absolute and relative, at the internal Na sites of their sodium pumps.4. The stimulation of the ouabain-sensitive ATPase activity by sensitization of the membranes with anti-L serum, is mediated by a threefold reduction of the K(m)/K(i) ratio at each site. K(m) decreases by a factor of 10, but there is also a smaller diminution of K(i). The maximal rate of hydrolysis, however, is unchanged by the anti-L treatment. The least-squares fitting of the pooled data by the rate equation, converges better with less than three and more than two equivalent sodium sites.5. The affinity sequence at two external K sites of the LK goat erythrocyte sodium pump, determined in the presence of 100 mM external Na, is Rb > K > Cs. It is obtained from the concentration dependence in influx experiments, and is the same as reported for human red cells.6. Cubic-root Dixon plots of the corrected ouabain-sensitive ATPase

  1. The theoretical approach for viscous and end effects on an MHD pump for sodium circulation

    International Nuclear Information System (INIS)

    Highlights: • The viscous and end effects on an MHD pump for the sodium circulation were analyzed. • The viscous effects are negligible compared with electromagnetic driving forces. • The end effects of the pump length are significant in high-velocity operation. - Abstract: The analyses of the viscous and end effects on a magnetohydrodynamic (MHD) pump for the sodium coolant circulation in Fast Reactors was carried out based on the MHD laminar flow analysis and the electromagnetic field theory. A one-dimensional MHD analysis for the liquid metal flowing through an annular channel has been performed on the basis of a simplified model of equivalent current sheets instead of three-phase currents in the discrete primary windings. The calculations show that the developed pressure difference resulted from electromagnetic and viscous forces in the liquid metal is expressed in terms of the slip, and that the viscous loss effects are negligible compared with electromagnetic driving forces except in the low-slip region where the pumps operate with very high flow velocities comparable with the synchronous velocity of the electromagnetic fields, which is not applicable to the practical MHD pumps. A two-dimensional electromagnetic field analysis based on an equivalent current sheet model has found the vector potentials in closed form by means of the Fourier transform method. The resultant magnetic fields and driving forces exerted on the liquid metal reveal that the end effects due to finiteness of the pump length are formidable. Calculations of each magnetic force contribution indicate that the end effects are originated from the magnetic force caused by the induced current generated by the liquid metal movement across the magnetic field rather than the one produced by externally applied magnetic fields by three-phase winding currents. It is concluded that since the influences of the end effects in addition to viscous losses are extensive particularly in high

  2. Na/K pump current in aggregates of cultured chick cardiac myocytes

    OpenAIRE

    1990-01-01

    Spontaneously beating aggregates of cultured embryonic chick cardiac myocytes, maintained at 37 degrees C, were voltage clamped using a single microelectrode switching clamp to measure the current generated by the Na/K pump (Ip). In resting, steady-state preparations an ouabain- sensitive current of 0.46 +/- 0.03 microA/cm2 (n = 22) was identified. This current was not affected by 1 mM Ba, which was used to reduce inward rectifier current (IK1) and linearize the current-voltage relationship. ...

  3. Predictive Reliability Assessment of the Automatic Clutch on a Primary Sodium Pump Drive

    International Nuclear Information System (INIS)

    This paper examines the reliability of a group of three clutch couplings each mounted between a pony motor and the main drive for the primary sodium pumps. The sodium pumps specification requires that continuously running AC pony motors be fitted to give a guaranteed 10% drive to the pumps in the event of a main supply failure. The drive to the main shaft is via 3 : 1 reduction gearing such that a six pole pony motor running at 300 rpm would drive the main shaft at 100 rpm i.e., 10% of its rated speed. In order that the pony motor drive could be permanently energised during normal operation a free wheeling clutch is fitted between the motor and the reduction gearing. The type of clutch chosen is. the Synchro-Self Shifting (SSS) clutch, shown in Figure 1. This type of clutch has proved itself under fairly onerous operating conditions, but is normally mounted on a horizontal driving shaft whereas in this case because of space limitations, it is necessary to mount it vertically. The reliability target set is that the chance of losing all three independent back-up pony motor drives on loss of main supplies should fall within the 10-5 - 10-6 band. Since the electrical supplies and other parts of the pony motor drives have been assessed within this target and some doubts expressed about the clutch it was now necessary to look at this in some detail

  4. Development of hardfacing materials for the use in hydrostatic bearings of sodium pumps

    International Nuclear Information System (INIS)

    This is a review of the work done on the development of hard facing materials for application in the hydrostatic bearing of the sodium pumps developed in the Netherlands for the joint German-Dutch-Belgian breeder reactor project (SNR). For various reasons cladding with Stellite 6 was chosen as the surface treatment for the bearings of the first generation of SNR pumps. Should the need arise, other -less conventional- materials are available for application. These include flame sprayed 'Stoody 90', a Stellite type material without nickel and with a relatively high cobalt content, two binary cobalt alloys, produced by an electroslag remelting technique, a stainless steel - tungsten carbide cermet and a cermet, consisting of tungsten carbide in a nickel-chromium matrix, both applied by flame spraying

  5. The Viscous and End Effects on an Electromagnetic Pumps for Sodium Circulation

    International Nuclear Information System (INIS)

    Analyses of the viscous and end effects on an electromagnetic (EM) pump for the sodium coolant circulation in Fast Reactors was carried out based on the MHD laminar flow analysis and the electromagnetic field theory. A one-dimensional MHD analysis for the liquid metal flowing through an annular channel has been performed on the basis of a simplified model of equivalent current sheets instead of three-phase currents in the discrete primary windings. The calculations show that the developed pressure difference resulted from electromagnetic and viscous forces in the liquid metal is expressed in terms of the slip, and that the viscous loss effects are negligible compared with electromagnetic driving forces except in the low-slip region where the pumps operate with very high flow velocities comparable with the synchronous velocity of the electromagnetic fields, which is not applicable to the practical EM pumps. A two-dimensional electromagnetic field analysis based on an equivalent current sheet model has found the vector potentials in closed form by means of the Fourier transform method. The resultant magnetic fields and driving forces exerted on the liquid metal reveal that the end effects due to finiteness of the pump length are formidable. Calculations of each magnetic force contribution indicate that the end effects are originated from the magnetic force caused by the induced current generated by the liquid metal movement across the magnetic field rather than the one produced by externally applied magnetic fields by three-phase winding currents. It is concluded that since the influences of the end effects in addition to viscous losses are extensive particularly in high-velocity operations of the EM pumps, it is necessary to find ways to suppress them, such as proper selection of the pump parameters and compensation of the end effects. (author)

  6. Proton Dependent Inhibition of the Cardiac Sodium Channel Nav1.5 by Ranolazine

    Directory of Open Access Journals (Sweden)

    PeterCRuben

    2013-06-01

    Full Text Available Ranolazine is clinically approved for treatment of angina pectoris and is a potential candidate for antiarrhythmic, antiepileptic and analgesic applications. These therapeutic effects of ranolazine hinge on its ability to inhibit persistent or late Na+ currents in a variety of voltage-gated sodium channels. Extracellular acidosis, typical of ischemic events, may alter the efficiency of drug/channel interactions. In this study, we examined pH modulation of ranolazine’s interaction with the cardiac sodium channel, Nav1.5. We performed whole-cell path clamp experiments at extracellular pH 7.4 and 6.0 on Nav1.5 transiently expressed in HEK293 cell line. Consistent with previous studies, we found that ranolazine induced a stable conformational state in the cardiac sodium channel with onset/recovery kinetics and voltage-dependence resembling intrinsic slow inactivation. This interaction diminished the availability of the channels in a voltage- and use-dependent manner. Low extracellular pH impaired inactivation states leading to an increase in late Na+ currents. Ranolazine interaction with the channel was also slowed 4-5 fold. However, ranolazine restored the voltage-dependent steady-state availability profile, thereby reducing window/persistent currents at pH 6.0 in a manner comparable to pH 7.4. These results suggest that ranolazine is effective at therapeutically relevant concentrations (10µM, in acidic extracellular pH, where it compensates for impaired native slow inactivation.

  7. The molecular size required varies according to the reaction step round the sodium pump cycle.

    Science.gov (United States)

    Cavieres, J D

    1987-12-10

    Progress along the path of the sodium pump cycle requires a stepwise recruitment of additional subunits for maximal activity. These results show that whereas a particle the size of the alpha beta protomer presents Na+,K+-ATPase activity at 10 microM ATP, an additional subunit, perhaps a second alpha-chain, is required to obtain the much greater Na+,K+-ATPase activity resulting from the occupation of low-affinity ATP sites at physiological ATP concentrations. A non-phosphorylating ATP analogue, however, will modestly stimulate the Na+,K+-ATPase activity acting at an alternative low-affinity site or step on the alpha beta protomer. PMID:2446918

  8. MHD stability analysis of a liquid sodium flow at the annular gap of an EM pump

    International Nuclear Information System (INIS)

    Highlights: ► A MHD stability analysis on an electromagnetic pump was carried out. ► Small perturbations for MHD fields were considered in sinusoidal form. ► Critical Reynolds number depends on the Hartman number and perturbed wave number. ► A magnetic field has a significant stabilizing effect on liquid sodium flow. - Abstract: A stability analysis of a viscous, incompressible, and electrically conducting liquid sodium flow in an annular linear induction electromagnetic pump for sodium coolant circulation of a Sodium Fast Reactor (SFR) was carried out when transverse magnetic fields permeate the sodium fluid across the narrow annular gap. Due to a negligible skin effect and the presence of a magnetic core outside the gap, radial magnetic field is assumed to be constant over the narrow channel gap, and the steady state solution of the axial velocity is obtained as a function of radius. Small perturbations for MHD fields were considered in sinusoidal form as a function of the angular frequency and wave number, and the resulting equations were linearized. The solutions of the perturbed equations were sought in the form of a linear combination of independent orthogonal functions in a non-dimensional radial interval (0, 1), and each orthogonal function was chosen to satisfy the boundary conditions of adhesion to the solid walls of the channel. Under the assumption that solutions of the equations were not oscillated rapidly according to the radial coordinate, finite numbers of orthogonal polynomials were considered. As a result, simultaneous equations with coefficients of steady-state solutions were arranged, and dispersion relations between angular frequency and wave number of perturbed state were sought. The imaginary part of the angular frequency was taken into consideration from the condition of existence of a nontrivial solution of the system, which leads to the relation between critical Reynolds number (Recr) and Hartmann number (Ha). In the present study

  9. 钠冷快堆超导钠泵建模与性能研究%Modeling and Performance Research on Sodium Cooled Fast Reactor Superconductive Sodium Pump

    Institute of Scientific and Technical Information of China (English)

    杨志达; 赵佳宁; 韩伟实

    2014-01-01

    为克服钠冷快堆机械式钠泵机械磨损、噪声大、泄漏以及普通电磁泵流量小、扬程小等问题,提出了大流量鞍型磁体的电磁泵作为驱动钠循环的主泵设计方案。对其结构进行了研究并建立了相应的数学模型,利用M atlab编写程序进行了不同电流、磁感应强度和温度条件下泵的扬程、流量和效率的性能研究。结果表明,扬程随通道宽度的增加、电流的减小、磁感应强度的减小而减小,效率随电流的减小、磁感应强度的减小而减小,温度高于400℃时由于接触电阻的降低可使效率提高,鞍型超导钠泵的流量可由电流、磁感应强度控制,但较为实用的是电流控制。该研究可为具体设计提供依据。%In order to overcome the shortcoming of sodium cooled fast reactor mechanical sodium pump including mechanical wear ,large noise ,sodium leakage and the shortcom-ing of electromagnetic pump including small flow rate and small pump head ,the large flow rate sodium pump design based on saddle superconductive magnet was put forward . The structure of sodium pump was researched and the mathematic model was estab-lished .The performance including pump head ,flow rate and efficiency were researched at different currents ,magnetic flux densities and temperatures using the computer code programmed with Matlab .The result shows that the pump head will reduce with the channel width increasing ,current reducing and magnetic flux density reducing ,and the efficiency will reduce with the current reducing and magnetic flux density reducing .If the temperature overtops 400 ℃ ,the efficiency will be high because of contact resistance disappearing .T he flow rate of the saddle type superconductive sodium pump can be controlled by current and magnetic flux density ,and the current is more suitable .This research can provide foundation for concreting design .

  10. Voltage and frequency dependent block of sodium current in cardiac cells. Comparison of the effect of two antiarrhythmic drugs

    Czech Academy of Sciences Publication Activity Database

    Matějovič, P.; Bahníková, M.; Pásek, Michal; Šimurdová, M.; Šimurda, J.

    Brno : Brno University of Technology, 2002 - (Jan, J.; Kozumplík, J.; Provazník, I.), s. 214-216 ISBN 80-214-2633-0. ISSN 1211-412X. [Biosignal 2002. Brno (CZ), 26.06.2002-28.06.2002] Institutional research plan: CEZ:AV0Z2076919 Keywords : cardiac cell * sodium current * antiarrhythmic drugs Subject RIV: BO - Biophysics

  11. Sodium pump isoform specificity for the digitalis-like factor isolated from human peritoneal dialysate.

    Science.gov (United States)

    Tao, Q F; Hollenberg, N K; Price, D A; Graves, S W

    1997-03-01

    We have isolated a labile, specific sodium pump inhibitor or digitalis-like factor from the peritoneal dialysate of volume-expanded renal failure patients whose levels correlated closely with volume status and blood pressure. This study characterizes the inhibitory profile of this agent compared with that of ouabain against the three alpha-isoforms of the sodium pump. We prepared microsomal Na,K-ATPase from rat tissues representing the highest proportion of one of the alpha-isoforms. Both Northern and Western blot analyses confirmed that kidney had predominantly the alpha1-isoform, skeletal muscle the alpha2-isoform, and fetal brain the alpha3-isoform. Ouabain (5 x 10(-6) mol/L) produced little inhibition of kidney Na,K-ATPase (3.4+/-2.0%) but significant inhibition of skeletal muscle (37.2+/-3.7%, P<.001) and fetal brain (38.8+/-3.5%, P<.001) activity. In contrast, the labile digitalis-like factor, causing comparable inhibition of fetal brain Na,K-ATPase activity (33.3+/-4.7%), produced markedly greater inhibition of kidney (42.5+/-5.6%, P<.001) and moderately greater inhibition of skeletal muscle pump activity (57.7+/-6.3%, P<.05). In addition, the labile digitalis-like factor produced a marked concentration-dependent inhibition of the alpha2- and alpha3-isoforms (r=.79, P=.00005). Experiments combining the labile digitalis-like factor and ouabain confirmed that digitalis-like factor, unlike ouabain, was an effective inhibitor of all three isoforms in rat, in particular alpha2. The different pattern of isoform sensitivity displayed by the labile digitalis-like factor and ouabain further differentiates the two agents and raises some interesting possibilities about the functional implications of the endogenous factor. PMID:9052901

  12. MtrA of the sodium ion pumping methyltransferase binds cobalamin in a unique mode.

    Science.gov (United States)

    Wagner, Tristan; Ermler, Ulrich; Shima, Seigo

    2016-01-01

    In the three domains of life, vitamin B12 (cobalamin) is primarily used in methyltransferase and isomerase reactions. The methyltransferase complex MtrA-H of methanogenic archaea has a key function in energy conservation by catalysing the methyl transfer from methyl-tetrahydromethanopterin to coenzyme M and its coupling with sodium-ion translocation. The cobalamin-binding subunit MtrA is not homologous to any known B12-binding proteins and is proposed as the motor of the sodium-ion pump. Here, we present crystal structures of the soluble domain of the membrane-associated MtrA from Methanocaldococcus jannaschii and the cytoplasmic MtrA homologue/cobalamin complex from Methanothermus fervidus. The MtrA fold corresponds to the Rossmann-type α/β fold, which is also found in many cobalamin-containing proteins. Surprisingly, the cobalamin-binding site of MtrA differed greatly from all the other cobalamin-binding sites. Nevertheless, the hydrogen-bond linkage at the lower axial-ligand site of cobalt was equivalently constructed to that found in other methyltransferases and mutases. A distinct polypeptide segment fixed through the hydrogen-bond linkage in the relaxed Co(III) state might be involved in propagating the energy released upon corrinoid demethylation to the sodium-translocation site by a conformational change. PMID:27324530

  13. The development of a cavitation free sodium pump for the breeder reactor

    International Nuclear Information System (INIS)

    The sodium pumps for a liquid metal fast breeder reactor must be designed for exceptionally high reliability and long life. The principal adverse factor which tends to limit the primary pump life is cavitation which becomes potentially severe under off-design flow conditions caused by the requirement of two loop operations which resulted in a large operating flow range. This problem prompted an extensive study which included experimental investigations of scaled down and full size pumps. The investigations involved visual observations, acoustic signature recordings, and physical characteristic measurements of the model and full size impellers. The blade configuration of the model was modified several times. After each modification intensive testing was conducted with feedback to established design criteria. The results obtained from the final configuration showed excellent cavitation performance. This configuration was then machined on the full scale impeller and tested. The results confirmed acceptable performance in the entire range of operating conditions. This paper describes the test facilities erected for this study, discusses the experimental techniques employed, and presents the experimental techniques employed, and presents a sample of the experimental results

  14. Effect of Sodium Tanshinone Ⅱ A Sulfonate on Cardiac Myocyte Hypertrophy and Its Underlying Mechanism

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Objective:To investigate the effects of sodium tanshinone Ⅱ A sulfonate (STS) on the hypertrophy induced by angiotensin Ⅱ (Ang Ⅱ) in primary cultured neonatal rat cardiac myocytes.Methods:The effect of STS on cytotoxicity was evaluated using the 3-(4,5-dimethylthiazol-2-yl)-3,5-phenytetrazoliumromide (MTT) assay.As indexes for cardiocyte hypertrophy,cell size was determined by phase contrast microscopy and protein synthesis rate was measured by 3H-leucine incorporation.The proto-oncogene c-fos mRNA expression of cardiocytes was assessed using reverse transcription polymerase chain reaction (RT-PCR).Results:STS could inhibit cardiocyte hypertrophy,increase the protein synthesis rate and enhance proto-oncogene c-los mRNA expression in cardiocytes induced by Ang Ⅱ (P<0.01),with an effect similar to that of Valsartan,the Ang Ⅱ receptor antagonist.Conclusion:STS can prevent the hypertrophy of cardiac myocytes induced by Ang Ⅱ,which may be related to its inhibition of the expression of proto-oncogene c-fos mRNA.

  15. Robust remote-pumping sodium laser for advanced LIDAR and guide star applications

    Science.gov (United States)

    Ernstberger, Bernhard; Enderlein, Martin; Friedenauer, Axel; Schwerdt, Robin; Wei, Daoping; Karpov, Vladimir; Leisching, Patrick; Clements, Wallace R. L.; Kaenders, Wilhelm G.

    2015-10-01

    The performance of large ground-based optical telescopes is limited due to wavefront distortions induced by atmospheric turbulence. Adaptive optics systems using natural guide stars with sufficient brightness provide a practical way for correcting the wavefront errors by means of deformable mirrors. Unfortunately, the sky coverage of bright stars is poor and therefore the concept of laser guide stars was invented, creating an artificial star by exciting resonance fluorescence from the mesospheric sodium layer about 90 km above the earth's surface. Until now, mainly dye lasers or sumfrequency mixing of solid state lasers were used to generate laser guide stars. However, these kinds of lasers require a stationary laser clean room for operation and are extremely demanding in maintenance. Under a development contract with the European Southern Observatory (ESO) and W. M. Keck Observatory (WMKO), TOPTICA Photonics AG and its partner MPB Communications have finalized the development of a next-generation sodium guide star laser system which is available now as a commercial off-the-shelf product. The laser is based on a narrow-band diode laser, Raman fiber amplifier (RFA) technology and resonant second-harmonic generation (SHG), thus highly reliable and simple to operate and maintain. It emits > 22 W of narrow-linewidth (≈ 5 MHz) continuous-wave radiation at sodium resonance and includes a re-pumping scheme for boosting sodium return flux. Due to the SHG resonator acting as spatial mode filter and polarizer, the output is diffraction-limited with RMS wavefront error space debris tracking as well as LIDAR applications.

  16. Distinct functional defect of three novel Brugada syndrome related cardiac sodium channel mutations

    Directory of Open Access Journals (Sweden)

    Juang Jyh-Ming

    2009-02-01

    Full Text Available Abstract The Brugada syndrome is characterized by ST segment elevation in the right precodial leads V1-V3 on surface ECG accompanied by episodes of ventricular fibrillation causing syncope or even sudden death. The molecular and cellular mechanisms that lead to Brugada syndrome are not yet completely understood. However, SCN5A is the most well known responsible gene that causes Brugada syndrome. Until now, more than a hundred mutations in SCN5A responsible for Brugada syndrome have been described. Functional studies of some of the mutations have been performed and show that a reduction of human cardiac sodium current accounts for the pathogenesis of Brugada syndrome. Here we reported three novel SCN5A mutations identified in patients with Brugada syndrome in Taiwan (p.I848fs, p.R965C, and p.1876insM. Their electrophysiological properties were altered by patch clamp analysis. The p.I848fs mutant generated no sodium current. The p.R965C and p.1876insM mutants produced channels with steady state inactivation shifted to a more negative potential (9.4 mV and 8.5 mV respectively, and slower recovery from inactivation. Besides, the steady state activation of p.1876insM was altered and was shifted to a more positive potential (7.69 mV. In conclusion, the SCN5A channel defect related to Brugada syndrome might be diverse but all resulted in a decrease of sodium current.

  17. The sodium pump modulates the influence of I(Na) on [Ca2+]i transients in mouse ventricular myocytes.

    OpenAIRE

    Su, Z; Sugishita, K; Ritter, M; Li, F; Spitzer, K W; Barry, W H

    2001-01-01

    To investigate whether activity of the sarcolemmal Na pump modulates the influence of sodium current on excitation-contraction (E-C) coupling, we measured [Ca(2+)](i) transients (fluo-3) in single voltage-clamped mouse ventricular myocytes ([Na+](pip) = 15 or 0 mM) when the Na pump was activated (4.4 mM K(+)(o)) and during abrupt inhibition of the pump by exposure to 0 K with a rapid solution-switcher device. After induction of steady state [Ca2+](i) transients by conditioning voltage pulses ...

  18. Fabrication of intermediate heat exchangers, steam generators, and sodium pumps for SNR-300

    International Nuclear Information System (INIS)

    The sodium pumps, intermediate heat exchangers, and steam generators for the liquid-metal fast breeder reactor (LMFBR) SNR-300 were delivered by Neratoom and its industrial partners Royal Schelde and Stork Boilers. All main components were delivered to and erected in the plant between 1983 and 1085 after a long period of delay, caused mainly by continuously changing requirements with respect to the latest state-of-the-art construction and design. It is therefore concluded that to realize an effective manufacturing of breeder components an authorized and final specification is absolutely necessary. After the legal formalization of the licensing step Teilgenehmigung 7/5, it was hardly possible to further change the specification of the SNR-300 components

  19. Fabrication of intermediate heat exchangers, steam generators, and sodium pumps for SNR-300

    Energy Technology Data Exchange (ETDEWEB)

    Van' t Hoft, A.J.; DeJong, J.J.; Vroom, J.P.; Kupers, G.R.

    1987-09-01

    The sodium pumps, intermediate heat exchangers, and steam generators for the liquid-metal fast breeder reactor (LMFBR) SNR-300 were delivered by Neratoom and its industrial partners Royal Schelde and Stork Boilers. All main components were delivered to and erected in the plant between 1983 and 1085 after a long period of delay, caused mainly by continuously changing requirements with respect to the latest state-of-the-art construction and design. It is therefore concluded that to realize an effective manufacturing of breeder components an authorized and final specification is absolutely necessary. After the legal formalization of the licensing step Teilgenehmigung 7/5, it was hardly possible to further change the specification of the SNR-300 components.

  20. Effect of silymarin on sodium fluoride-induced toxicity and oxidative stress in rat cardiac tissues

    Directory of Open Access Journals (Sweden)

    Seyed M. Nabavi

    2012-12-01

    Full Text Available This study aim to evaluate the protective effect of silymarin on sodium fluoride-induced oxidative stress in rat cardiac tissues. Animals were pretreated with silymarin at 20 and 10 mg/kg prior to sodium fluoride consumption (600 ppm through drinking water. Vitamin C at 10 mg/kg was used as standard antioxidant. There was a significant increase in thiobarbituric acid reactive substances level (59.36 ± 2.19 nmol MDA eq/g tissue along with a decrease in antioxidant enzymes activity (64.27 ± 1.98 U/g tissue for superoxide dismutase activity and 29.17 ± 1.01 µmol/min/mg protein for catalase activity and reduced glutathione level (3.8 ± 0.15 µg/mg protein in the tissues homogenates of the sodium fluoride-intoxicated rats. Silymarin administration to animals before sodium fluoride consumption modified the levels of biochemical parameters.Este estudo objetiva avaliar o efeito protetor da silimarina em fluoreto de sódio induzida por estresse oxidativo em tecido cardíaco de ratos. Os animais foram pré-tratados com silimarina a 20 e 10 mg/kg antes do consumo de fluoreto de sódio (600 ppm através da água de beber. A vitamina C a 10 mg/kg foi utilizada como antioxidante padrão. Houve um aumento significativo no nível de substâncias tiobarbitúrico reativo de ácido (59,36 ± 2.19 nmol MDA eq/g tecido, juntamente com uma diminuição da atividade de enzimas antioxidantes (64,27 ± 1,98 U/g tecido para a atividade de superóxido dismutase e 29,7 ± 1,01 mmol/min/mg de proteína para a atividade da catalase e nível de glutationa reduzida (3,8 ± 0,15 mg/mg de proteína nos homogeneizados de tecidos dos fluoreto de sódio-intoxicados ratos. Administração de silimarina a animais, antes do consumo de fluoreto de sódio modifou os níveis de parâmetros bioquímicos.

  1. Potassium homeostasis during exercise in domestic species: the role of the sodium-potassium pump in skeletal muscle

    NARCIS (Netherlands)

    Everts, Maria E.

    2001-01-01

    In 1997, Jens Christian Skou was awarded the Nobel prize in Chemistry for his discovery and elegant description, some 40 years earlier, of the sodium-potassium (Na+,K+) pump in crab nerve fibres [37]. It is now widely accepted that this cation transport system is essential for cell function, and tha

  2. Qualitative and quantitative analyses of the morphological-dynamics of early cardiac pumping function using video densitometry and optical coherence tomography (OCT)

    DEFF Research Database (Denmark)

    Happel, C.; Männer, J.; Thommes, J.;

    Introduction: During the initial phase of its pump action, vertebrate embryonic hearts are seen as valveless tubular pumps. It was traditionally thought that these tubular hearts generate unidirectional blood flow via peristalsis. Recently, however, the pumping mechanism of early embryonic hearts...... has become a matter of dispute. Uncovering of the pumping mechanism of tubular embryonic hearts requires detailed information about the hemodynamics as well as morphological dynamics of the pump action. We have analyzed the morphological dynamics of cardiac pump action in chick embryos (HH-stage 16...... site. Moreover, we show, for the first time, the pump action of tubular embryonic chick hearts in frontal views, which provide a much better understanding of early cardiac pump action than the traditional right or left lateral views. Summary: OCT M-mode recordings and video densitometric analyses show...

  3. Lack of agreement between esophageal doppler cardiac output measurements and continuous pulse contour analysis during off-pump cardiac surgery

    Directory of Open Access Journals (Sweden)

    H. V. Groesdonk

    2010-03-01

    Full Text Available Objective: Transesophageal echo-Doppler cardiac output as well as arterial pulse contour analyses cardiac output are increasingly used for cardiac output monitoring. No data are available whether both techniques may be used interchangeably in patients undergoing cardiac surgery. Design: Prospective, observational study Setting: Operating rooms of a university affiliated hospital. Patients: 30 patients undergoing elective coronary artery bypass grafting surgery.Interventions: NoneMeasurements: 900 paired cardiac output measurements were obtained by pulse contour analysis following transpulmonary thermodilution equilibration by the PiCCO system (PiCCO, Pulsion, Munich, Germany and by the HemoSonic esophageal doppler monitor (HemoSonic 100; Arrow International, Reading, PA. Measurements were performed within the first hour after induction of anesthesia. Results: Bland-Altman analysis of the complete data set showed a mean difference (bias of - 0.12 l/min (95% CI -0.06 to -0.18 with limits of agreement + 1.8 l/min to -1.6 l/min (upper 95% CI 1.78 to 1.98; lower 95% CI -1.74 to -1.54, the percentage error was + 37% to -44.5%. Transesophageal echo-Doppler cardiac output closely correlated (r = 0.75, p < 0.0001 with pulse-contour analyses cardiac output. Conclusions: Several studies have shown the accuracy of calibrated pulse contour cardiac output measurements in patients undergoing cardiac surgery. Thus, the present data question the reliability of transesophageal echo-Doppler derived cardiac output measurements in this setting and may have implications for using transesophageal echo-Doppler during goal-directed hemodynamic optimization.

  4. Large-scale expression of recombinant cardiac sodium-calcium exchange in insect larvae.

    Science.gov (United States)

    Hale, C C; Zimmerschied, J A; Bliler, S; Price, E M

    1999-02-01

    Recombinant bovine cardiac sodium-calcium exchange (NCX1) in a baculovirus construct was used to infect cabbage looper larvae (Trichoplusia ni). Infected larvae were homogenized and larvae membrane vesicles were purified. Western blot analysis indicated the presence of recombinant NCX1 protein in vesicles from infected larvae but not in controls. Vesicles from infected larvae expressed high levels of NCX1 activity (1.7 nmol Ca2+/mg protein/s) while vesicles from control larvae had no activity. NCX1 in larvae vesicles was bidirectional. Kinetic analysis yielded a Vmax of 3.6 nmol Ca2+/mg protein/s and a Km for Ca of 4.2 microM. NCX1 activity was inhibited by the exchange inhibitory peptide with an IC50 of 4 microM. These data demonstrate a novel and efficient method for the expression of large amounts of active recombinant NCX1 protein that has general application for expression and analysis of recombinant membrane proteins. PMID:10024479

  5. Endurance Exercise Training Reduces Cardiac Sodium/Calcium Exchanger Expression in Animals Susceptible to Ventricular Fibrillation

    Directory of Open Access Journals (Sweden)

    GeorgeEBillman

    2011-02-01

    Full Text Available Aim: Increased sodium/calcium exchanger activity (NCX1, an important regulator of cardiomyocyte cystolic calcium may provoke arrhythmias. Exercise training can decrease NCX1 expression in animals with heart failure improving cytosolic calcium regulation, and could thereby reduce the risk for ventricular fibrillation (VF. Methods: To test this hypothesis, a 2-min coronary occlusion was made during the last min. of exercise in dogs with healed myocardial infarctions; 23 had VF (S, susceptible and 13 did not (R, resistant. The animals were randomly assigned to either 10-wk exercise training (progressively increasing treadmill running (S n = 9; R n = 8 or 10-wk sedentary (S n = 14; R n = 5 groups. At the end of the 10-wk period, the exercise + ischemia test provoked VF in sedentary but not trained susceptible dogs. On a subsequent day, cardiac tissue was harvested and NCX1 protein expression was determined by Western blot. Results: In the sedentary group, NCX1 expression was significantly (ANOVA, P<0.05 higher in susceptible compared to resistant dogs. In contrast, NCX1 levels were similar in the exercise trained resistant and susceptible animals. Conclusion: These data suggest that exercise training can restore a more normal NCX1 level in dogs susceptible to ventricular fibrillation, improving cystolic calcium regulation and could thereby reduce the risk for sudden death following myocardial infarction.

  6. Activation of KATP channels by Na/K pump in isolated cardiac myocytes and giant membrane patches.

    OpenAIRE

    Kabakov, A Y

    1998-01-01

    Strophanthidin inhibits KATP channels in 2,4-dinitrophenol-poisoned heart cells (). The current study shows that the Na/K pump interacts with KATP current (IK-ATP) via submembrane ATP depletion in isolated giant membrane patches and in nonpoisoned guinea pig cardiac cells in whole-cell configuration. IK-ATP was inhibited by ATP, glibenclamide, or intracellular Cs+. Na/K pump inactivation by substitution of cytoplasmic Na+ for Li+ or N-methylglucamine decreased both IK-ATP by 1/3 (1 mM ATP, ze...

  7. Cardiac sodium channel Na(v)1.5 interacts with and is regulated by the protein tyrosine phosphatase PTPH1

    DEFF Research Database (Denmark)

    Jespersen, Thomas; Gavillet, Bruno; van Bemmelen, Miguel X; Cordonier, Sophie; Thomas, Marc A; Staub, Olivier; Abriel, Hugues

    2006-01-01

    In order to identify proteins interacting with the cardiac voltage-gated sodium channel Na(v)1.5, we used the last 66 amino acids of the C-terminus of the channel as bait to screen a human cardiac cDNA library. We identified the protein tyrosine phosphatase PTPH1 as an interacting protein. Pull-d...

  8. The mesospheric sodium layer as a remotely, optically pumped magnetometer for investigation of Birkeland currents

    Science.gov (United States)

    Johnsen, Magnar G.; Matzka, Jürgen; Hoppe, Ulf-Peter

    2016-04-01

    By means of optical pumping, it is possible to use the naturally occurring sodium layer in the mesosphere to measure Earth's scalar magnetic field at ~90 km above ground. This is an altitude not accessible by other means than rockets, which only will provide point measurements of very short time scales. We are planning to modify the sodium lidar at ALOMAR in Northern Norway to be able, for the first time, to measure and monitor the magnetic field in situ in the high latitude mesosphere over longer time scales. The planned modifications to the lidar instrument will allow alternating between the new magnetometer mode and its present mode for atmospheric temperatures and winds. The technique, which has been proposed earlier for measurements at low or mid-latitudes for studies of Earth's internal magnetic field, will in our project be applied to high latitudes in the auroral zone. This opens for a completely new domain of measurements of externally generated geomagnetic variations related to currents in the magnetosphere-ionosphere system. In particular, we aim to measure the magnetic field variations in close vicinity to Birkeland currents associated with particle precipitation events penetrating to altitudes below 90 km and small-scale, discrete auroral arcs. It is, furthermore, anticipated that it will be possible to detect horizontal current structures in the E-layer on much smaller length scales than it is presently possible from ground observations alone. During the project we plan take advantage of the rich space science infrastructure located in northern Norway, including ALOMAR, EISCAT and the Tromsø Geophysical Observatory magnetometer network. If possible, we also aim to make measurements in conjunction with overpasses of the SWARM satellites.

  9. Pump, sodium, inducer, intermediate size (ISIP) (impeller/inducer/diffuser retrofit)

    International Nuclear Information System (INIS)

    This specification defines the requirements for the Intermediate-Size Inducer Pump (ISIP), which is to be made by replacing the impeller of the FFTF Prototype Pump with a new inducer, impeller, diffuser, seal, and necessary adapter hardware. Subsequent testing requirements of the complete pump assembly are included

  10. Study of an electromagnetic pump applied to a primary main pump of a large scale sodium cooled reactor

    International Nuclear Information System (INIS)

    This paper describes a future innovative design options with a parallel electromagnetic pump (EMP) system as the main circulating pump of the JSFR design. A conceptual design of EMPs integrated with an intermediate heat exchanger (IHX) is carried out. The major design parameters are consistent with the current JSFR design, where the main flow rate is 630 m3/min and the flow halving time is the same of the mechanical pump with the similar reliability. As a result of several design studies, a five parallel EMPs with IHX system has been selected from the geometry suitability for JSFR design. The EMP advantages comparing with mechanical pumps are investigated from the views of in-service inspection, maintenance and reliability. Numerical analysis with two dimensional MHD codes is conducted on a former experiment of a 160 m3/min flow rate EMP. The overall trend of the experimental data and the numerical results agrees with that in small-scale EMPs. However, the difference between the experimental data and the numerical results seems larger compared with the small-scale EMPs, which comes from large magnetic Reynolds number and interaction parameter of 160 m3/min EMP. (author)

  11. Qualitative and quantitative analyses of the morphological-dynamics of early cardiac pump action using video densidometry and optical coherence tomography (OCT)

    DEFF Research Database (Denmark)

    Männer, Jörg; Thrane, Lars; Thommes, Jan;

    2010-01-01

    During the initial phase of its pump action, vertebrate embryonic hearts are seen as valveless tubular pumps. It was traditionally thought that these tubular hearts generate unidirectional blood flow via peristalsis. Recently, however, the pumping mechanism of early embryonic hearts has become a...... matter of dispute. Uncovering of the pumping mechanism of tubular embryonic hearts requires detailed information about the hemodynamics as well as morphological dynamics of their pump action. We have therefore analyzed the morphological dynamics of cardiac pump action in chick embryos (HH-stages 16...... embryos. We have recorded striking differences in the contraction behavior (e.g. contraction speed, duration of systolic occlusion of heart lumen) of the embryonic heart segments (common atrium, AV-canal, embryonic ventricles, outflow tract). Moreover, we show, for the first time, the pump action of...

  12. Inherited Cardiac Diseases Caused by Mutations in the Nav1.5 Sodium Channel

    DEFF Research Database (Denmark)

    Tfelt-Hansen, Jacob; Winkel, Bo Gregers; Grunnet, Morten;

    2009-01-01

    Cardiac Diseases Caused by SCN5A Mutations. A prerequisite for a normal cardiac function is a proper generation and propagation of electrical impulses. Contraction of the heart is obtained through a delicate matched transmission of the electrical impulses. A pivotal element of the impulse propaga......-QT syndrome, Brugada syndrome, and AF, reported to be associated with mutations in SCN5A, are thoroughly described. (J Cardiovasc Electrophysiol, Vol. pp. 1-9)....

  13. Evaluation on the fretting abrasion of heat-transfer tubes of the integrated IHX/primary sodium pump. 1. Workrate analyses model

    International Nuclear Information System (INIS)

    The cost minimization of commercialized FBR plant systems requires the integration of an intermediate-heat-exchanger (IHX) and a primary sodium mechanical pump into one component. The pump is installed in the center of the integrated component and heat transfer tubes surround the pump. Primary sodium flows down inside the heat transfer tubes and secondary sodium flows up outside the tubes in a zigzag. Therefore, the pump rotation and sodium flow induce the vibration of heat transfer tubes and it leads the tubes to fretting wearing against support plates. Then the tube wearing must be evaluated to confirm its integrity during the plant life span (60 years). However, the knowledge of the pump rotation influence on tube wearing is not sufficiently acquired because the integrated component is a new concept in JNC. To evaluate the tube fretting wearing ratio due to the pump rotation, a new calculation model of FINAS was composed. In the first place, the beam vibration analysis model of a pump shaft, shells, tube bundle etc. of the integrated component reveals its properties such as frequency, amplitude and vibration mode. In the second place, based on the above mentioned vibration analysis, the frequency and amplitude of abrasion between the tubes and support plates can be obtained by a contact analysis model of FINAS. Eventually, this calculation shows that the tube wearing will not affect the tube integrity during the plant life time. However further evaluation by more detailed analysis and abrasion tests are needed to obtain more accurate results. (author)

  14. [The cardioprotective action of the anticonvulsant preparation sodium valproate in disorders of cardiac contractile function caused by acute myocardial infarct in rats].

    Science.gov (United States)

    Belkina, L M; Korchazhkina, N B; Kamskova, Iu G; Fomin, N A

    1997-01-01

    The preventive and therapeutical effects of sodium valproate (SV), 200 mg/kg, on cardiac contractile disorders (developed pressure, rate-pressure products, dp/dt) were studied in rats having 2-day myocardial infarction (MI). The postinfarction rather than preinfarction use of SV substantially restricted the depressed resting left ventricular function. Given by two regimens, SV increased cardiac resistance to the maximum isometric load induced by 60-sec ligation of the ascending aorta. The cardioprotective effect of the drug was shown due to its positive chronotropic action rather than its inotropic one. Thus, SV may be used as an effective drug for the prevention and treatment of postinfarct cardiac dysfunctions. PMID:9235532

  15. Downstream shift in sodium pump activity along the nephron during acute hypertension

    DEFF Research Database (Denmark)

    Magyar, C E; Zhang, Y; Holstein-Rathlou, N H;

    2001-01-01

    medullary Na,K-ATPase activity from 20 +/- 3.5 to 27 +/- 6.4 micromol Pi/mg protein per h while decreasing renal cortex activity from 10.9 +/- 0.9 to 6.5 +/- 0.7. Hypertension and benzolamide also doubled medullary alkaline phosphatase activity. As chronic hypertension develops in the young spontaneously......Acute hypertension rapidly inhibits proximal tubule (PT) Na,K-ATPase activity and sodium reabsorption 30 to 40%, increasing sodium and volume delivery to the thick ascending loop of Henle (TALH) and macula densa, providing the error signal for tubuloglomerular feedback. The hypothesis was tested in...... rats that an acute increase in sodium and volume delivery to the TALH would acutely increase outer medulla Na,K-ATPase activity. Flow to the TALH was increased by either (1) elevating BP (102 to 160 mmHg) for 5 min by constricting arteries (hypertension) or (2) inhibiting PT sodium and volume...

  16. The effects of residual pump blood on patient plasma free haemoglobin levels post cardiac surgery.

    Science.gov (United States)

    H, Schotola; Aj, Wetz; Af, Popov; I, Bergmann; Bc, Danner; Fa, Schöndube; M, Bauer; A, Bräuer

    2016-09-01

    At the end of cardiopulmonary bypass, there are invariably several hundred millilitres of residual pump blood in the reservoir, which can either be re-transfused or discarded. The objective of this prospective observational study was to investigate the quality of the residual pump blood, focusing on plasma free haemoglobin (pfHb) and blood cell counts. Fifty-one consecutive patients were included in the study. Forty-nine units of residual pump blood and 58 units of transfused red blood cell (RBC) concentrates were analysed. The mean preoperative pfHb of the patients was 0.057 ± 0.062 g/l, which increased gradually to 0.55 ± 0.36 g/l on arrival in the intensive care unit postoperatively. On the first postoperative day, the mean pfHb had returned to within the normal range. Our data showed that haemoglobin, haematocrit, and erythrocyte counts of residual pump blood were approximately 40% of the values in standardised RBC concentrates. Plasma free haemoglobin was significantly higher in residual pump blood compared to RBC concentrates, and nearly twice as high as the pfHb in patient blood samples taken contemporaneously. Our findings indicate that residual pump blood pfHb levels are markedly higher compared to patients' blood and RBC concentrates, but that its administration does not significantly increase patients' pfHb levels. PMID:27608341

  17. Clinical evaluation of the Spiral Pump® after improvements to the original project in patients submitted to cardiac surgeries with cardiopulmonary bypass

    OpenAIRE

    Jarbas Jakson Dinkhuysen; Aron Jose Pazin de Andrade; Juliana Leme; Cibele Silva; Claudia Sanches Medina; Cristiane Célia Pereira; José Francisco Biscegli

    2014-01-01

    Objective: The objective of this paper is to present the results from Spiral Pump clinical trial after design modifications performed at its previous project. This pump applies axial end centrifugal hydraulic effects for blood pumping during cardiopulmonary bypass for patients under cardiac surgery. Methods: This study was performed in 52 patients (51% males), between 20 to 80 (67±14.4) years old weighing 53 to 102 (71.7±12.6) kg, mostly under myocardial revascularization surgery (34.6%)...

  18. Risk factors for delirium after on-pump cardiac surgery : A systematic review

    NARCIS (Netherlands)

    Gosselt, Alex N C; Slooter, Arjen J C; Boere, Pascal R Q; Zaal, Irene J.

    2015-01-01

    Introduction: As evidence-based effective treatment protocols for delirium after cardiac surgery are lacking, efforts should be made to identify risk factors for preventive interventions. Moreover, knowledge of these risk factors could increase validity of etiological studies in which adjustments ne

  19. PRINCIPLES OF DEVELOPMENT MATHEMATICAL MODEL FOR RESEARCHING OF NONPULSATILE FLOW PUMP AND CARDIAC SYSTEM

    Directory of Open Access Journals (Sweden)

    I. V. Bykov

    2013-01-01

    Full Text Available Aim. The presented research uncovers the using of mathematical modeling methods for cardio-vascular system and axial blood pump interaction analysis under heart failure with combined valve pathology. The research will pro- vide data for automated pump control algorithm synthesis. Materials and methods. Mathematical model is build up by using experiments results from mock cardio-vascular circulation loop and mathematical representation of Newtonian fluid dynamics in pulsing circulation loop. The model implemented in modeling environment Simulink (Matlab. Results. Authors implemented mathematical model which describe cardio-vascular system and left-ven- tricular assistive device interaction for intact conditions. Values of parameters for intact conditions were acquired in the experiments on animals with implanted axial pump, experiments were conducted in FRCTAO. The model was verified by comparison of instantaneous blood flowrate values in experiments and in model. Conclusion. The paper present implemented mathematical model of cardio-vascular system and axial pump interaction for intact conditions, where the pump connected between left ventricle and aorta. In the next part of research authors will use the presented model to evaluate using the biotechnical system in conditions of heart failure and valve pathology. 

  20. Conditioning techniques and ischemic reperfusion injury in relation to on-pump cardiac surgery

    DEFF Research Database (Denmark)

    Holmberg, Fredrik Eric Olof; Ottas, Konstantin Alex; Andreasen, Charlotte;

    2014-01-01

    OBJECTIVES: The objective was to investigate the potential protective effects of two conditioning methods, on myocardial ischemic and reperfusion injury in relation to cardiac surgery. DESIGN: Totally 68 patients were randomly assigned to either a control group (n = 23), a remote ischemic....... The other secondary endpoints were metabolic parameters related to myocardial ischemia, measured using microdialysis technique, as well as other operative- and postoperative data. RESULTS: Postoperative cardiac enzyme release indicated a possible beneficial effect of the interventions, but the difference...... did not reach statistical significance. RIPC showed a trend toward lower levels (p = 0.07). We managed to establish a functional myocardial microdialysis model, but we were unable to demonstrate clear protective effects. CONCLUSIONS: We were in this prospective randomized proof-of-concept trial...

  1. Effects of Amiodarone and N-desethylamiodarone on Cardiac Voltage-Gated Sodium Channels

    OpenAIRE

    Ghovanloo, Mohammad-Reza; Abdelsayed, Mena; Ruben, Peter C.

    2016-01-01

    Amiodarone (AMD) is a potent antiarrhythmic drug with high efficacy for treating atrial fibrillation and tachycardia. The pharmacologic profile of AMD is complex. AMD possesses biophysical characteristics of all of class I, II, III, and IV agents. Despite its adverse side effects, AMD remains the most commonly prescribed antiarrhythmic drug. AMD was described to prolong the QT interval and can lead to torsades de pointes. Our goal was to study the effects of AMD on peak and late sodium curren...

  2. Proton Dependent Inhibition of the Cardiac Sodium Channel Nav1.5 by Ranolazine

    OpenAIRE

    PeterCRuben; SridharanRajamani

    2013-01-01

    Ranolazine is clinically approved for treatment of angina pectoris and is a potential candidate for antiarrhythmic, antiepileptic and analgesic applications. These therapeutic effects of ranolazine hinge on its ability to inhibit persistent or late Na+ currents in a variety of voltage-gated sodium channels. Extracellular acidosis, typical of ischemic events, may alter the efficiency of drug/channel interactions. In this study, we examined pH modulation of ranolazine’s interaction with the ca...

  3. Proton-dependent inhibition of the cardiac sodium channel Nav1.5 by ranolazine

    OpenAIRE

    Sokolov, S.; Peters, C. H.; Rajamani, S; Ruben, P C

    2013-01-01

    Ranolazine is clinically approved for treatment of angina pectoris and is a potential candidate for antiarrhythmic, antiepileptic, and analgesic applications. These therapeutic effects of ranolazine hinge on its ability to inhibit persistent or late Na+ currents in a variety of voltage-gated sodium channels. Extracellular acidosis, typical of ischemic events, may alter the efficiency of drug/channel interactions. In this study, we examined pH modulation of ranolazine's interaction with the ca...

  4. Ionic diffusion in voltage-clamped isolated cardiac myocytes. Implications for Na,K-pump studies.

    OpenAIRE

    Mogul, D J; Singer, D H; ten Eick, R E

    1989-01-01

    The whole-cell voltage-clamp technique employing electrolyte-filled micro-pipette suction electrodes is widely used to investigate questions requiring an electrophysiological approach. With this technique, the ionic composition of the cytosol is assumed to be strongly influenced (as result of diffusion) by the ionic composition of the solution contained in the electrode. If this assumption is valid for isolated cardiac myocytes, the technique would be particularly powerful for studying the de...

  5. Functional suppression of Kcnq1 leads to early sodium channel remodelling and cardiac conduction system dysmorphogenesis

    Czech Academy of Sciences Publication Activity Database

    De la Rosa, A. J.; Domínguez, J. N.; Sedmera, D.; Šaňková, Barbora; Hove-Madsen, L.; Franco, D.; Aránega, A. E.

    2013-01-01

    Roč. 98, č. 3 (2013), s. 504-514. ISSN 0008-6363 R&D Projects: GA ČR(CZ) GA304/08/0615; GA ČR(CZ) GAP302/11/1308; GA ČR(CZ) GD204/09/H084; GA ČR(CZ) GA13-12412S Institutional research plan: CEZ:AV0Z50110509 Institutional support : RVO:67985823 Keywords : ion channels * Long-QT syndrome * sudden death * cardiac hypertrophy Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery Impact factor: 5.808, year: 2013

  6. Ultrafast pump-probe reflectance spectroscopy: Why sodium makes Cu(In,Ga)Se2 solar cells better

    KAUST Repository

    Eid, Jessica

    2015-04-14

    Although Cu(In,Ga)Se2 (CIGS) solar cells have the highest efficiency of any thin-film solar cell, especially when sodium is incorporated, the fundamental device properties of ultrafast carrier transport and recombination in such cells remain not fully understood. Here, we explore the dynamics of charge carriers in CIGS absorber layers with varying concentrations of Na by femtosecond (fs) broadband pump-probe reflectance spectroscopy with 120 fs time resolution. By analyzing the time-resolved transient spectra in a different time domain, we show that a small amount of Na integrated by NaF deposition on top of sputtered Cu(In,Ga) prior to selenization forms CIGS, which induces slower recombination of the excited carriers. Here, we provide direct evidence for the elongation of carrier lifetimes by incorporating Na into CIGS.

  7. Assertion based verification methodology for HDL designs of primary sodium pump speed and eddy current flow measurement systems of PFBR

    International Nuclear Information System (INIS)

    With the growing complexity and size of digital designs, functional verification has become a huge challenge. The validation and testing process accounts for a significant percentage of the overall development effort and cost for electronic systems. Many studies have shown that up to 70% of the design development time and resources are spent on functional verification. Functional errors manifest themselves very early in the design flow, and unless they are detected upfront, they can result in severe consequences - both financially and from a safety viewpoint. This paper covers the various types of verification methodologies and focuses on Assertion Based Verification Methodology for HDL designs, taking as case studies, the Primary Sodium Pump Speed and Eddy Current Flow Measurement Systems of PFBR. (author)

  8. Sodium test of the Super-Phenix full size primary pump shaft on the CPV-1 test rig at ENEA-Brasimone

    International Nuclear Information System (INIS)

    Tests aimed to verify Super Phenix primary pump rotating assembly behaviour in normal and accidental operating conditions. The tests were conducted on a CPV-1 loop reproducing the operating conditions (sodium-temperature and level, shaft inclination, etc...): thermal tests, hydrostatic bearing and bending velocity measures, endurance tests on the rotating assembly, rig dynamic behaviour, seismic tests

  9. Dependence of Na-K pump current on internal Na+ in mammalian cardiac myocytes.

    Science.gov (United States)

    Mogul, D J; Singer, D H; Ten Eick, R E

    1990-08-01

    Na-K pump current (Ipump) is a function of the intracellular Na+ concentration [( Na+]i). We examined the quantitative relationship between Ipump and [Na+]i in isolated guinea pig ventricular myocytes under steady-state conditions. [Na+]i was controlled and "clamped" at several selected concentrations using wide-tipped pipette microelectrodes, and membrane current was measured using the whole cell patch voltage-clamp technique. Ipump generated at a holding potential of -40 mV was determined by measuring the change in steady-state holding current before and during exposure to dihydroouabain (1 mM); Ipump was measured at 11 levels of [Na+]i ranging from 0 to 80 mM (n = 63) with only one measurement per cell and normalized to cell capacitance to account for differences between myocytes in sarcolemmal surface area. Ipump exhibited a nonlinear dependence on [Na+]i; a Hill analysis of the relationship yielded a half-maximal [Na+]i for pump stimulation of 43.2 mM and a Hill coefficient of 1.53. An alternative analysis of the experimental data was performed assuming that occupation of three internal binding sites by Na+ is required for enzyme turnover. Regression analysis gave the best fit when only two different binding affinities (KD) are postulated. The values are KD1 = 1 mM, KD2 = KD3 = 29 mM. From the analysis using the latter model, the level of [Na+]i at which Ipump saturated closely approximated the theoretical saturation level calculated from published estimates of pump turnover rate and density. The maximal sensitivity of the Na-K pump to changes in [Na+]i occurs when internal [Na+] is within the range for the normal resting physiological level. PMID:2167023

  10. D2O and the sodium pump in squid nerve membrane

    International Nuclear Information System (INIS)

    In 10 K artificial seawater (ASW), D2O replacement reduced the Na efflux of squid axons by about one third. In 0 K ASW, D2O replacement had little effect. D2O reduced the K+ sensitivity of the efflux but increased the affinity for K+. A 4 degrees decrease in temperature mimicked the effects of D2O. When axons were injected with arginine, to decrease the ATP/ADP ratio, they lost K+ sensitivity in normal ASW, as expected. Their efflux into 0 K ASW became D2O sensitive. The results are discussed in terms of conformational changes in the Na pump molecular complex

  11. Nav1.5 cardiac sodium channels, regulation and clinical implications

    Directory of Open Access Journals (Sweden)

    Henry Humberto León-Ariza

    2014-10-01

    Full Text Available Voltage-gated sodium channels constitute a group of membrane proteins widely distributed thought the body. In the heart, there are at least six different isoforms, being the Nav1.5 the most abundant. The channel is composed of an α subunit that is formed by four domains of six segments each, and four much smaller β subunits that provide stability and integrate other channels into the α subunit. The function of the Nav1.5 channel is modulated by intracellular cytoskeleton proteins, extracellular proteins, calcium concentration, free radicals, and medications, among other things. The study of the channel and its alterations has grown thanks to its association with pathogenic conditions such as Long QT syndrome, Brugada syndrome, atrial fibrillation, arrhythmogenic ventricular dysplasia and complications during ischemic processes.

  12. The β1-subunit of Na(v1.5 cardiac sodium channel is required for a dominant negative effect through α-α interaction.

    Directory of Open Access Journals (Sweden)

    Aurélie Mercier

    Full Text Available Brugada syndrome (BrS is an inherited autosomal dominant cardiac channelopathy. Several mutations on the cardiac sodium channel Na(v1.5 which are responsible for BrS lead to misfolded proteins that do not traffic properly to the plasma membrane. In order to mimic patient heterozygosity, a trafficking defective mutant, R1432G was co-expressed with Wild Type (WT Na(v1.5 channels in HEK293T cells. This mutant significantly decreased the membrane Na current density when it was co-transfected with the WT channel. This dominant negative effect did not result in altered biophysical properties of Na(v1.5 channels. Luminometric experiments revealed that the expression of mutant proteins induced a significant reduction in membrane expression of WT channels. Interestingly, we have found that the auxiliary Na channel β(1-subunit was essential for this dominant negative effect. Indeed, the absence of the β(1-subunit prevented the decrease in WT sodium current density and surface proteins associated with the dominant negative effect. Co-immunoprecipitation experiments demonstrated a physical interaction between Na channel α-subunits. This interaction occurred only when the β(1-subunit was present. Our findings reveal a new role for β(1-subunits in cardiac voltage-gated sodium channels by promoting α-α subunit interaction which can lead to a dominant negative effect when one of the α-subunits shows a trafficking defective mutation.

  13. Changes in cardiac glycoside receptor sites 86 rubidium uptake and intracellular sodium concentrations in the erythrocytes of patients receiving digoxin during the early phases of treatment of cardiac failure in regular rhythm and of atrial fibrillation

    International Nuclear Information System (INIS)

    Measurements of the binding of 12-α-[3H]-digoxin to the membranes of intact erythrocytes, erythrocytic 86Rb uptake and intraerythrocytic sodium concentrations have been made in the red cells of patients receiving digoxin in the short-term for atrial fibrillation or cardiac failure in regular rhythm. During the first few days of treatment [3H]-digoxin binding and 86Rb uptake fall and intraerythrocytic sodium concentrations rise. Subsequently parallel fluctuations occur in [3H]-digoxin binding and 86Rb uptake but not in intraerythrocytic sodium concentrations and the significance of the fluctuations is discussed. The values of all three measurements correlate significantly with the response of the heart in sinus rhythm as measured by QS2I. Plasma digoxin concentrations do not correlate with QS2I. (author)

  14. Recent experiences gained from manufacturing of the main heat transfer components and sodium pumps for SNR-300

    International Nuclear Information System (INIS)

    The paper deals with the work performed by Neratoom and its partners during the manufacturing of the main heat transfer components (steam generators and intermediate heat exchangers) and the primary and secondary sodium pumps for SNR-300, taking into consideration the experience gained from prototype testing. All SNR-300 main components were delivered to and erected in the Kalkar LMFBR plant from 1983 to 1985, after a long period of manufacturing (1972-1984). The delay was mainly caused by the continuously increasing requirements, imposed by the licensing authorities, with respect to the latest state of the art of construction and design. An important conclusion is that in order to realize an effective manufacturing of breeder components an authorized and final specification is an absolute necessity. After the legal formalization of the relevant licensing step in 1982 it was no longer possible to change the specification of the SNR-300 components. This led to a speeding up of manufacturing activities; the components were even completed ahead of the revised schedules. Therefore the procedure which is now planned for the post-SNR-300 LMFBR (SNR-2), to obtain a manufacturing licence before starting fabrication, should be regarded as the most important step towards a commercial LMFBR. The progress made in the manufacture and completion of the components in the period 1980-1985 is also described, including the latest design changes, for instance the use of large forgings for the helical steam generator and the optimized support structures for the intermediate heat exchangers and the secondary pumps. (author)

  15. Effects of Amiodarone and N-Desethylamiodarone on Cardiac Voltage-gated Sodium Channels

    Directory of Open Access Journals (Sweden)

    Mohammad-Reza eGhovanloo

    2016-03-01

    Full Text Available Amiodarone (AMD is a potent antiarrhythmic drug with high efficacy for treating atrial fibrillation and tachycardia. The pharmacologic profile of AMD is complex. AMD possesses biophysical characteristics of all of class I, II, III, and IV agents. Despite its adverse side effects, AMD remains the most commonly prescribed antiarrhythmic drug. AMD was described to prolong the QT interval and can lead to torsades de pointes. Our goal was to study the effects of AMD on peak and late sodium currents (INa,P and INa,L and determine whether these effects change as AMD is metabolized into N-Desethylamiodarone (DES. We hypothesized that AMD and DES block both INa,P and INa,L with similar profiles due to structural similarities. Given the inherent small amounts of INa,L in NaV1.5, we screened AMD and DES against the Long QT-3-causing mutation, ∆KPQ, to better detect any drug-mediated effect on INa,L. Our results show that AMD and DES do not affect WT or ∆KPQ activation; however, both drugs altered the apparent valence of steady-state fast-inactivation. In addition, AMD and DES preferentially block ∆KPQ peak conductance compared to WT. Both compounds significantly increase INa,L and window currents. We conclude that both compounds have pro-arrhythmic effects on NaV1.5, especially ∆KPQ; however, DES seems to have a greater pro-arrhythmic effect than AMD.

  16. Release of 86Rb from rat submandibular gland slices: relation to sodium pump activity

    International Nuclear Information System (INIS)

    Slices of rat submandibular gland were preloaded with 86Rb, an isotope that can substitute for K+ in the K+ release process. The efflux of 86Rb was monitored in a superfusion apparatus that efficiently removed the 86Rb as it exited from the tissue slices. Carbachol and the calcium ionophore A23187 activated a calcium-dependent increase in 86Rb efflux. Dibutyryl cGMP had no detectable effect on 86Rb efflux in contrast to its activation of ouabain-sensitive uptake of 86Rb observed in an earlier study. The stimulated release of 86Rb was not dependent on the presence of either sodium or chloride ion. When 86Rb efflux was stimulated by carbachol, the efflux rate returned toward the basal rate after a few minutes of exposure to carbachol in the medium. If ouabain was then introduced into the superfusate, a large increase in efflux was stimulated. In the absence of carbachol, only a small increase in 86Rb efflux was stimulated by ouabain. The effect of ouabain indicates that there was a substantial recycling of 86Rb between the release and uptake processes in the extracellular space of the tissue slice. The significance of this observation is discussed

  17. Stimulation of sodium pump by vasoactive intestinal peptide in guinea-pig isolated trachea: potential contribution to mechanisms underlying relaxation of smooth muscle.

    OpenAIRE

    Morrison, K. J.; Vanhoutte, P. M.

    1996-01-01

    1. Relaxation of airway smooth muscle induced by vasoactive intestinal peptide (VIP) is mediated by adenosine 3':5' cyclic monophosphate (cyclic AMP). An interaction between the synthesis of cyclic AMP and enzymic activity of the plasmalemmal sodium pump (Na(+)-K(+)-ATPase) exists in certain isolated cell systems. This study sought to determine the contribution of Na(+)-K(+)-ATPase activity to relaxation of airway smooth muscle evoked by VIP. 2. All experiments were performed on isolated stri...

  18. EFFECTS OF OUABAIN AND DIGOXIN ON THE GENE EXPRESSION OF SODIUM PUMP α-SUBUNIT ISOFORM IN AORTIC SMOOTH MUSCLE OF RATS

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Objective To compare the effects of ouabain and digoxin on both the systolic blood pressure and sodium pump α-subunit isoforms gene expression in the aortic smooth muscle of rats. Methods Normal SpragueDawley rats were injected with ouabain (20μg·kg-1 ·d-1 ,i. p),digoxin (32 μg·kg-1 ·d-1,i. p)and normal saline once a day, respectively, and indirect systolic blood pressure was recorded once a week. Six weeks later,all the rats were killed and sodium pump α1-,α2-,and α3-subunit mRNA levels were detected in the aortic smooth muscle with reverse transcription polymerase chain reaction(RT-PCR) method. Results The systolic blood pressure of rats infused with ouabain increased significantly at the end of week 6 [132. 6± 9. 0 mmHg (1 mmHg = 0. 133 kPa)vs 115. 7±8.2mmHg, P <0. 01] ,while no difference of blood pressure was found between digoxin group and NS group (P>0.05).The expression of sodium pump α-subunit isoforms in aortic smooth muscle was regulated by either ouabain or digoxin:both ouabain and digoxin increased α1- and α3-subunit expression, α2-subunit decreased in digoxin group but unchanged in ouabain group. Conclusion These results suggest that both ouabain and digoxin could regulate sodium pump α-subunit isoform expression, which might be related to the physiological roles of endogenous ouabain and might be responsible for the difference between the pharmacological and toxicological effects of ouabain and digoxin,including their effects on blood pressure.

  19. Seismic tests in sodium of the SPX-1 primary pump shaft carried out in the CPV-1 test rig at ENEA-Brasimone

    International Nuclear Information System (INIS)

    Dynamic tests were carried out by ISMES, on behalf of ENEA and CEA and in co-operation with FIAT/TTG, on a SPX-1 primary pump shaft. These tests were conducted, mainly in sodium, in the CPV-1 test rig at the ENEA Brasimone Center. The excitation was applied to the flange supporting the hydrostatic bearing. After some preliminary analysis performed in absence of liquid sodium and at ambient temperature, the following tests were performed on the rig filled with sodium at operating temperature: (A) sine sweeps between 1 and 15 Hz, (B) ambient vibration investigation, and (C) seismic tests with a SSE acceleration time-history (20 s duration) calculated by CEA at hydrostatic bearing level. Two sets of seismic tests were carried out, each time increasing amplitudes up to 70% of SSE. This value was not exceeded for safety reasons and actuator power limit. The first set of tests began in nominal operating conditions; when 70% of SSE was reached, pressure feed to hydrostatic bearing was reduced lowering its effective support. This simulated a larger earthquake. The second set of tests was representative of SPX-1 pump actual operating conditions, because both hydrostatic bearing pressure and shaft rotating speed were simultaneously reduced following the primary pump characteristic curve. The tests allowed the SPX-1 pump rotating set to be widely qualified. Among the main results, it is worth noting that the stiffness of the hydrostatic bearing system was generally compatible with seismic requirements. Finally, it is worth pointing out that, in order to allow the above-mentioned tests to be carried out, a full seismic qualification of the CPV-1 test rig was necessary: thus, this rig might be used in the future for further seismic tests on LMFBR components and systems in sodium. (author). Figs and tabs

  20. Possible involvement of membrane lipids peroxidation and oxidation of catalytically essential thiols of the cerebral transmembrane sodium pump as component mechanisms of iron-mediated oxidative stress-linked dysfunction of the pump's activity.

    Science.gov (United States)

    Omotayo, T I; Akinyemi, G S; Omololu, P A; Ajayi, B O; Akindahunsi, A A; Rocha, J B T; Kade, I J

    2015-01-01

    The precise molecular events defining the complex role of oxidative stress in the inactivation of the cerebral sodium pump in radical-induced neurodegenerative diseases is yet to be fully clarified and thus still open. Herein we investigated the modulation of the activity of the cerebral transmembrane electrogenic enzyme in Fe(2+)-mediated in vitro oxidative stress model. The results show that Fe(2+) inhibited the transmembrane enzyme in a concentration dependent manner and this effect was accompanied by a biphasic generation of aldehydic product of lipid peroxidation. While dithiothreitol prevented both Fe(2+) inhibitory effect on the pump and lipid peroxidation, vitamin E prevented only lipid peroxidation but not inhibition of the pump. Besides, malondialdehyde (MDA) inhibited the pump by a mechanism not related to oxidation of its critical thiols. Apparently, the low activity of the pump in degenerative diseases mediated by Fe(2+) may involve complex multi-component mechanisms which may partly involve an initial oxidation of the critical thiols of the enzyme directly mediated by Fe(2+) and during severe progression of such diseases; aldehydic products of lipid peroxidation such as MDA may further exacerbate this inhibitory effect by a mechanism that is likely not related to the oxidation of the catalytically essential thiols of the ouabain-sensitive cerebral electrogenic pump. PMID:25618580

  1. Possible involvement of membrane lipids peroxidation and oxidation of catalytically essential thiols of the cerebral transmembrane sodium pump as component mechanisms of iron-mediated oxidative stress-linked dysfunction of the pump's activity

    Directory of Open Access Journals (Sweden)

    T.I. Omotayo

    2015-04-01

    Full Text Available The precise molecular events defining the complex role of oxidative stress in the inactivation of the cerebral sodium pump in radical-induced neurodegenerative diseases is yet to be fully clarified and thus still open. Herein we investigated the modulation of the activity of the cerebral transmembrane electrogenic enzyme in Fe2+-mediated in vitro oxidative stress model. The results show that Fe2+ inhibited the transmembrane enzyme in a concentration dependent manner and this effect was accompanied by a biphasic generation of aldehydic product of lipid peroxidation. While dithiothreitol prevented both Fe2+ inhibitory effect on the pump and lipid peroxidation, vitamin E prevented only lipid peroxidation but not inhibition of the pump. Besides, malondialdehyde (MDA inhibited the pump by a mechanism not related to oxidation of its critical thiols. Apparently, the low activity of the pump in degenerative diseases mediated by Fe2+ may involve complex multi-component mechanisms which may partly involve an initial oxidation of the critical thiols of the enzyme directly mediated by Fe2+ and during severe progression of such diseases; aldehydic products of lipid peroxidation such as MDA may further exacerbate this inhibitory effect by a mechanism that is likely not related to the oxidation of the catalytically essential thiols of the ouabain-sensitive cerebral electrogenic pump.

  2. 快堆钠泵机械密封可靠性评价%Reliability Assessment of Sodium Pump Mechanical Seal for Fast Reactor

    Institute of Scientific and Technical Information of China (English)

    浦恩山; 谷继品; 肖丽丽

    2016-01-01

    According to the collected lifetime data ,the reliability assessment of the sodi‐um pump mechanical seals for Russian fast reactor was completed by Weibull distribu‐tion .And then the reliability information of the sodium pump mechanical seals was obtained .The reliability assessment based on the collected lifetime data of domestic mechanical seals was completed by optimal confidence limit method ,whose assessment results were compared with those of Russian sodium pump mechanical seals .The calcu‐lation results show that the reliabilities for Russian sodium pump mechanical seals and domestic mechanical seals are no less than 0.947 3 and 0.874 4 ,respectively ,with 0.8 one‐sided confidence limits of 25 000 operation hours . T he results of the reliability assessment show that the reliability of the sodium pump mechanical seals for Russian pump is better than the mechanical seals’ on domestic pump ,but the gap between the two is not significant .%基于所收集的俄罗斯钠泵机械密封的寿命数据,利用基于威布尔分布的分析方法对其进行可靠性评价,得到了其可靠性信息。对国内机械密封所收集的寿命数据,利用最优置信限法对其进行可靠性评价,并将评价结果与俄罗斯钠泵机械密封的评价结果进行了对比分析。结果显示,在置信度为0畅8,寿命为25000 h时,俄罗斯钠泵机械密封的可靠度不低于0畅9473,国内的机械密封可靠度不低于0畅8744。可靠性评价结果表明,国内机械密封的可靠性与俄罗斯钠泵机械密封的可靠性有一定的差距,但差距不是很大。

  3. High-power QCW microsecond-pulse solid-state sodium beacon laser with spiking suppression and D2b re-pumping.

    Science.gov (United States)

    Bian, Qi; Bo, Yong; Zuo, Jun-wei; Guo, Chuan; Xu, Chang; Tu, Wei; Shen, Yu; Zong, Nan; Yuan, Lei; Gao, Hong-wei; Peng, Qin-jun; Chen, Hong-bin; Feng, Lu; Jin, Kai; Wei, Kai; Cui, Da-fu; Xue, Sui-jian; Zhang, Yu-dong; Xu, Zu-yan

    2016-04-15

    A 65 W quasi-continuous-wave microsecond-pulse solid-state sodium beacon laser tuned to the sodium D2a line has been developed with a linewidth of 0.3 GHz, beam quality of M2=1.38, and pulse width of 120 μs at a repetition rate of 500 Hz by sum-frequency mixing 1319 and 1064 nm diode-pumped Nd:YAG master-oscillator power-amplifier systems. The laser wavelength stability is less than ±0.15 GHz through feedback controlling. The laser spiking due to relaxation oscillations is suppressed by inserting frequency doublers in both 1319 and 1064 nm oscillators. Sodium D2b re-pumping is accomplished by tuning the frequency of the electro-optic modulator with the right D2a-D2b offset. A bright sodium laser guide star with a photon return of 1820 photons/cm2/s was achieved with the laser system when a 32 W circular polarized beam was projected to the sky during our field test at the Xinglong Observatory. PMID:27082331

  4. AFRL Advanced Electric Lasers Branch - Construction and Upgrade of a 50-watt Facility-Class Sodium Guidestar Pump Laser

    Science.gov (United States)

    Bronder, T.; Miller, H.; Stohs, J.; Lu, C.; Baker, J.; Lucero, A.

    The development of a reliable and effective laser source for pumping mesospheric sodium to generate an artificial guidestar has been well documented. From the early achievements with 589nm high-power dye lasers at the Keck and Lick observatories to the ground-breaking 50W CW FASOR (Frequency Addition Source of Optical Radiation) Guidestar at the Air Forces Starfire Optical Range (SOR), there has been intense interest in this technology from both the academic and military communities. Beginning in the fall of 2008, the Air Force Research Laboratorys Advanced Electric Lasers Branch began a project to build, test, verify and deliver an upgraded version of the SOR FASOR for use at the AF Maui Optical Station (AMOS) in the summer of 2010. This FASOR will be similar in design to the existing SOR device and produce 50W of diffraction limited, linearly polarized narrow linewidth 589nm light by combining the output of two injection-locked Nd:YAG ring lasers (operating at 1064nm and 1319nm) using resonant sum-frequency generation in a lithium triborate crystal (LBO). The upgraded features will include modularized sub-components, embedded control electronics, and a simplified cooling system. The first portion of this upgrade project is to reconstruct the current SOR FASOR components and include improved methods of regulating the gain modules of the two injection lasers. In parallel with this effort, the technical plans for the modularization and re-packaging of the FASOR will be finalized and coordinated with the staff at Maui. This presentation will summarize the result of these efforts to date and provide updates on the AMOS FASOR status. Additionally, plans for "next-generation" FASOR upgrades for both SOR and AMOS will also be discussed.

  5. Cardiac sodium channel Na(v)1.5 interacts with and is regulated by the protein tyrosine phosphatase PTPH1.

    Science.gov (United States)

    Jespersen, Thomas; Gavillet, Bruno; van Bemmelen, Miguel X; Cordonier, Sophie; Thomas, Marc A; Staub, Olivier; Abriel, Hugues

    2006-10-01

    In order to identify proteins interacting with the cardiac voltage-gated sodium channel Na(v)1.5, we used the last 66 amino acids of the C-terminus of the channel as bait to screen a human cardiac cDNA library. We identified the protein tyrosine phosphatase PTPH1 as an interacting protein. Pull-down experiments confirmed the interaction, and indicated that it depends on the PDZ-domain binding motif of Na(v)1.5. Co-expression experiments in HEK293 cells showed that PTPH1 shifts the Na(v)1.5 availability relationship toward hyperpolarized potentials, whereas an inactive PTPH1 or the tyrosine kinase Fyn does the opposite. The results of this study suggest that tyrosine phosphorylation destabilizes the inactivated state of Na(v)1.5. PMID:16930557

  6. Clinical Effectiveness of Centrifugal Pump to Produce Pulsatile Flow During Cardiopulmonary Bypass in Patients Undergoing Cardiac Surgery

    NARCIS (Netherlands)

    Gu, Y. John; van Oeveren, Willem; Mungroop, Hubert E.; Epema, Anne H.; den Hamer, Inez J.; Keizer, Jorrit J.; Leuvenink, Ron P.; Mariani, Massimo A.; Rakhorst, Gerhard

    2011-01-01

    Although the centrifugal pump has been widely used as a nonpulsatile pump for cardiopulmonary bypass (CPB), little is known about its performance as a pulsatile pump for CPB, especially on its efficacy in producing hemodynamic energy and its clinical effectiveness. We performed a study to evaluate w

  7. Evaluation on the fretting abrasion of heat-transfer tubes of the integrated IHX/primary sodium pump. 2. Fretting wearing analyses

    International Nuclear Information System (INIS)

    A primary sodium pump is installed in the center of an integrated component and heat transfer tubes surround the pump. Then, the pump rotation induces the vibration of heat transfer tubes and it leads the tubes to fretting wearing against support plates. Therefore, the tube wearing must be evaluated to confirm its integrity during the plant life span (60 years). This report describes the results of the tube wearing analysis by using vibration and wearing calculation models. In the first place, the vibration analysis of a pump shaft, shells, tube bundle etc. of the integrated component reveals its properties such as frequency, amplitude and vibration mode. In the second place, based on the above mentioned vibration analysis, the wearing analysis model shows the frequency and amplitude of the fretting wearing between tubes and support plates and the wearing depth of tubes. The amplitude of the pump vibration, vibration transmission paths and the contact condition between tubes and support plates especially affect the tube wearing, then the wearing evaluation needs that conservative calculation conditions must be found out by surveying these parameters. This calculation result indicates that the tube abrasion does not affect the tube integrity during the plant life time. However further evaluation by more detailed analysis and vibration and wearing tests are needed to acquire more accurate results. (author)

  8. Assessment of hydraulic performance and biocompatibility of a MagLev centrifugal pump system designed for pediatric cardiac or cardiopulmonary support.

    Science.gov (United States)

    Dasse, Kurt A; Gellman, Barry; Kameneva, Marina V; Woolley, Joshua R; Johnson, Carl A; Gempp, Thomas; Marks, John D; Kent, Stella; Koert, Andrew; Richardson, J Scott; Franklin, Steve; Snyder, Trevor A; Wearden, Peter; Wagner, William R; Gilbert, Richard J; Borovetz, Harvey S

    2007-01-01

    The treatment of children with life-threatening cardiac and cardiopulmonary failure is a large and underappreciated public health concern. We have previously shown that the CentriMag is a magnetically levitated centrifugal pump system, having the utility for treating adults and large children (1,500 utilized worldwide). We present here the PediVAS, a pump system whose design was modified from the CentriMag to meet the physiological requirements of young pediatric and neonatal patients. The PediVAS is comprised of a single-use centrifugal blood pump, reusable motor, and console, and is suitable for right ventricular assist device (RVAD), left ventricular assist device (LVAD), biventricular assist device (BVAD), or extracorporeal membrane oxygenator (ECMO) applications. It is designed to operate without bearings, seals and valves, and without regions of blood stasis, friction, or wear. The PediVAS pump is compatible with the CentriMag hardware, although the priming volume was reduced from 31 to 14 ml, and the port size reduced from 3/8 to (1/4) in. For the expected range of pediatric flow (0.3-3.0 L/min), the PediVAS exhibited superior hydraulic efficiency compared with the CentriMag. The PediVAS was evaluated in 14 pediatric animals for up to 30 days, demonstrating acceptable hydraulic function and hemocompatibility. The current results substantiate the performance and biocompatibility of the PediVAS cardiac assist system and are likely to support initiation of a US clinical trial in the future. PMID:18043164

  9. The specific case: cardiac amyloidosis as differential diagnosis in case of restricted cardiac pump function; Der besondere Fall. Amyloidose des Herzens als Differenzialdiagnose bei eingeschraenkter kardialer Pumpfunktion

    Energy Technology Data Exchange (ETDEWEB)

    D' Errico, L. [Universitaetsspital Basel (Switzerland). Klinik fuer Radiologie und Nuklearmedizin; Zellweger, M.; Niemann, T.

    2014-03-15

    The NMR imaging data in combination with clinical characterization and echocardiography are consistent with the diagnosis of a cardiac amyloidosis. The article describes disease pattern and diagnosis based on contrast agent accumulation and diastolic functional disturbances. CT was performed to exclude pulmonary embolism.

  10. Sodium-potassium pump activity in white blood cells from children with an increased risk of developing hypertension--The Odense Schoolchild Study

    DEFF Research Database (Denmark)

    Hansen, H S; Nielsen, J R; Pedersen, K E;

    1993-01-01

    We have measured the capacity of the sodium-potassium pump, as assessed by 86rubidium uptake and the number of [3H]-ouabain binding sites on white blood cells, in children aged 9-11 years, partly cross-sectionally and partly longitudinally after a physical training programme. Children from a...... hypertensive subgroup comprising the upper 5% of the blood pressure distribution and children from a randomly selected normotensive subgroup were eligible for the study. In the cross-sectional study 40 children from the hypertensive subgroup and 40 children from the normotensive subgroup were evaluated. A...... significant increase in 86rubidium uptake was present in boys as compared to girls. After adjustment for differences in sexual maturation the observed significant difference disappeared. Important correlates of pump activity were height, plasma glucose, and physical fitness. In the training study 10 boys from...

  11. Retinoic acid and sodium butyrate suppress the cardiac expression of hypertrophic markers and proinflammatory mediators in Npr1 gene-disrupted haplotype mice.

    Science.gov (United States)

    Subramanian, Umadevi; Kumar, Prerna; Mani, Indra; Chen, David; Kessler, Isaac; Periyasamy, Ramu; Raghavaraju, Giri; Pandey, Kailash N

    2016-07-01

    The objective of the present study was to examine the genetically determined differences in the natriuretic peptide receptor-A (NPRA) gene (Npr1) copies affecting the expression of cardiac hypertrophic markers, proinflammatory mediators, and matrix metalloproteinases (MMPs) in a gene-dose-dependent manner. We determined whether stimulation of Npr1 by all-trans retinoic acid (RA) and histone deacetylase (HDAC) inhibitor sodium butyric acid (SB) suppress the expression of cardiac disease markers. In the present study, we utilized Npr1 gene-disrupted heterozygous (Npr1(+/-), 1-copy), wild-type (Npr1(+/+), 2-copy), gene-duplicated (Npr1(++/+), 3-copy) mice, which were treated intraperitoneally with RA, SB, and a combination of RA/SB, a hybrid drug (HB) for 2 wk. Untreated 1-copy mice showed significantly increased heart weight-body weight (HW/BW) ratio, blood pressure, hypertrophic markers, including beta-myosin heavy chain (β-MHC) and proto-oncogenes (c-fos and c-jun), proinflammatory mediator nuclear factor kappa B (NF-κB), and MMPs (MMP-2, MMP-9) compared with 2-copy and 3-copy mice. The heterozygous (haplotype) 1-copy mice treated with RA, SB, or HB, exhibited significant reduction in the expression of β-MHC, c-fos, c-jun, NF-κB, MMP-2, and MMP-9. In drug-treated animals, the activity and expression levels of HDAC were significantly reduced and histone acetyltransferase activity and expression levels were increased. The drug treatments significantly increased the fractional shortening and reduced the systolic and diastolic parameters of the Npr1(+/-) mice hearts. Together, the present results demonstrate that a decreased Npr1 copy number enhanced the expression of hypertrophic markers, proinflammatory mediators, and MMPs, whereas an increased Npr1 repressed the cardiac disease markers in a gene-dose-dependent manner. PMID:27199456

  12. REVIEW ARTICLE: Optical pumping-induced spatio-temporal modifications to propagation, polarization and intensity of laser beams in sodium vapour

    Science.gov (United States)

    Holzner, R.; Dangel, S.

    1998-02-01

    Circularly polarized laser beams propagating through sodium vapour and tuned to the buffer-gas-broadened atomic 1355-5111/10/1/003/img1 transition can optically pump sodium atoms into a non-absorbing ground state. This causes an intensity-dependent refractive index gradient along as well as transverse to the laser beam propagation direction, giving rise to a number of nonlinear spatio-temporal intensity and polarization pattern creating processes. In the case of a single circularly polarized laser beam we have observed self-focusing and defocusing, the transformation of the incident Gaussian beam intensity profiles into ring profiles, a large shift of about 5 GHz of the maximum of the absorption profile when suitable magnetic fields are applied and the deflection of a beam by the inhomogeneous transverse magnetic field of a current-carrying wire. When two beams of opposite circular polarization are superimposed, astonishing effects such as the mutual deflection of both beams (beam bouncing), the mutual extinction of both beams (beam switching), the separation of initially overlapping beams (beam splitting) and the mutual attraction of both beams (beam attraction) can be observed. While most of the effects can be well described for the stationary state by a 1355-5111/10/1/003/img2 to 1355-5111/10/1/003/img3 atomic transition model, the correct description of the dynamics requires the consideration of all hyperfine states.

  13. A proton leak current through the cardiac sodium channel is linked to mixed arrhythmia and the dilated cardiomyopathy phenotype.

    Directory of Open Access Journals (Sweden)

    Pascal Gosselin-Badaroudine

    Full Text Available Cardiac Na(+ channels encoded by the SCN5A gene are essential for initiating heart beats and maintaining a regular heart rhythm. Mutations in these channels have recently been associated with atrial fibrillation, ventricular arrhythmias, conduction disorders, and dilated cardiomyopathy (DCM.We investigated a young male patient with a mixed phenotype composed of documented conduction disorder, atrial flutter, and ventricular tachycardia associated with DCM. Further family screening revealed DCM in the patient's mother and sister and in three of the mother's sisters. Because of the complex clinical phenotypes, we screened SCN5A and identified a novel mutation, R219H, which is located on a highly conserved region on the fourth helix of the voltage sensor domain of Na(v1.5. Three family members with DCM carried the R219H mutation.The wild-type (WT and mutant Na(+ channels were expressed in a heterologous expression system, and intracellular pH (pHi was measured using a pH-sensitive electrode. The biophysical characterization of the mutant channel revealed an unexpected selective proton leak with no effect on its biophysical properties. The H(+ leak through the mutated Na(v1.5 channel was not related to the Na(+ permeation pathway but occurred through an alternative pore, most probably a proton wire on the voltage sensor domain.We propose that acidification of cardiac myocytes and/or downstream events may cause the DCM phenotype and other electrical problems in affected family members. The identification of this clinically significant H(+ leak may lead to the development of more targeted treatments.

  14. A new index of cardiac left ventricular synergic pumping efficiency to detect kinematically subtle coronary artery disease

    International Nuclear Information System (INIS)

    Detection of kinematically subtle coronary artery disease (CAD) is quite difficult when there is normal global left ventricular ejection fraction response to supine ergometric (isotonic) exercise. A new index of left ventricular synergic pumping efficiency (LV-SPE) has been defined conceptually and mathematically. Hand-grip (isometric) stress induced change of LV-SPE has been found to be a very useful parameter in detecting CAD in the presence of minimally produced wall motion abnormalities, which are liable to be otherwise scintigraphically too blurred when evaluated by isotonic exercise methods and thus evade proper analysis. (author). 21 refs., 2 figs., 1 tab

  15. BIOMATERIALS FOR ROTARY BLOOD PUMPS

    NARCIS (Netherlands)

    VANOEVEREN, W

    1995-01-01

    Rotary blood pumps are used for cardiac assist and cardiopulmonary support since mechanical blood damage is less than with conventional roller pumps. The high shear rate in the rotary pump and the reduced anticoagulation of the patient during prolonged pumping enforces high demands on the biocompati

  16. Sudden Cardiac Arrest

    Science.gov (United States)

    ... scan, or MUGA, which shows how well your heart is pumping blood. Magnetic resonance imaging (MRI) which gives doctors detailed pictures of your heart. How is SCA treated? Sudden cardiac arrest should ...

  17. Electromagnetic pump

    International Nuclear Information System (INIS)

    The present invention provides an electromagnetic pump suitable to a recycling pump for liquid sodium as coolants of an FBR type reactor. Namely, a stator module of the electromagnetic pump of the present invention comprises a plurality of outer laminate iron core units and outer stator modules stacked alternately in the axial direction. With such a constitution, even a long electromagnetic pump having a large number of outer stator coils can be manufactured without damaging electric insulation of the outer stator coils. In addition, the inner circumferential surface of the outer laminate iron cores is urged and brought into contact with the outer circumferential surface of the outer duct by an elastic material. With such a constitution, Joule loss heat generated in the outer stator coils and internal heat generated in the outer laminate iron cores can be released to an electroconductive fluid flowing the inner circumference of the outer duct by way of the outer duct. (I.S.)

  18. Pump impeller

    International Nuclear Information System (INIS)

    A mixed-flow pump impeller, which may be used, for example, as a primary pump for circulating sodium as the primary coolant in a fast nuclear reactor, is described which comprises an impeller with evenly-spaced blades. Some of the blades, which are symmetrically disposed around the axis of rotation of the impeller, extend beyond the ends of the other blades towards the suction side of the pump to form an inducer. The channels defined between the extensions of the extended blades follow helical paths parallel to the axis of rotation. The leading edges of the unextended blades are interposed between the extended blades in the region of divergence of flow from the axis of rotation. The provision of the inducer reduces the risk of cavitation in the pump, which could cause rapid wear of the impeller. A shroud may be provided for the unextended blades. (author)

  19. Cardiac voltage-gated sodium channel Nav1.5 is regulated by Nedd4-2 mediated ubiquitination.

    Science.gov (United States)

    van Bemmelen, Miguel X; Rougier, Jean-Sébastien; Gavillet, Bruno; Apothéloz, Florine; Daidié, Dorothée; Tateyama, Michihiro; Rivolta, Ilaria; Thomas, Marc A; Kass, Robert S; Staub, Olivier; Abriel, Hugues

    2004-08-01

    Na(v)1.5, the cardiac isoform of the voltage-gated Na+ channel, is critical to heart excitability and conduction. However, the mechanisms regulating its expression at the cell membrane are poorly understood. The Na(v)1.5 C-terminus contains a PY-motif (xPPxY) that is known to act as binding site for Nedd4/Nedd4-like ubiquitin-protein ligases. Because Nedd4-2 is well expressed in the heart, we investigated its role in the ubiquitination and regulation of Na(v)1.5. Yeast two-hybrid and GST-pulldown experiments revealed an interaction between Na(v)1.5 C-terminus and Nedd4-2, which was abrogated by mutating the essential tyrosine of the PY-motif. Ubiquitination of Na(v)1.5 was detected in both transfected HEK cells and heart extracts. Furthermore, Nedd4-2-dependent ubiquitination of Na(v)1.5 was observed. To test for a functional role of Nedd4-2, patch-clamp experiments were performed on HEK cells expressing wild-type and mutant forms of both Na(v)1.5 and Nedd4-2. Na(v)1.5 current density was decreased by 65% upon Nedd4-2 cotransfection, whereas the PY-motif mutant channels were not affected. In contrast, a catalytically inactive Nedd4-2 had no effect, indicating that ubiquitination mediates this downregulation. However, Nedd4-2 did not alter the whole-cell or the single channel biophysical properties of Na(v)1.5. Consistent with the functional findings, localization at the cell periphery of Na(v)1.5-YFP fusion proteins was reduced upon Nedd4-2 coexpression. The Nedd4-1 isoform did not regulate Na(v)1.5, suggesting that Nedd4-2 is a specific regulator of Na(v)1.5. These results demonstrate that Na(v)1.5 can be ubiquitinated in heart tissues and that the ubiquitin-protein ligase Nedd4-2 acts on Na(v)1.5 by decreasing the channel density at the cell surface. PMID:15217910

  20. The microstructure of a small scale AISI 316 stainless steel pumped sodium loop following operation for 20,000h

    International Nuclear Information System (INIS)

    A small pumped loop constructed of AISI 316 stainless steel has been operated for 20,000 hrs. with a peak temperature of 6350C. Marked decarburisation was observed in the preheater and in the adjacent specimen chamber. No regions of significant carburisation were found. The decarburisation of the heat input areas appears to be a consequence of the large temperature difference between the hot and cold legs. In addition the steel temperatures in the hot regions are such as to allow relatively high solid state mobility of carbon. The absence of significant carburisation in other parts is attributed to the lower temperatures which leads to a gradual reduction in carbon activity over a sink area which is large in relation to that of the source. Additionally, the mobility of carbon is reduced at the lower temperatures found in the cooler regions of the loop. Tentatively applying the results to a fast reactor circuit suggests the occurrence of decarburisation in the high heat input regions ie the fuel clad, with corresponding but more widely distributed, and hence less significant, carburisation in other regions. (author)

  1. Getting Pumped About Heart Failure

    OpenAIRE

    Mann, Douglas L.

    2014-01-01

    Heart failure is a clinical syndrome caused by dysregulated calcium handling and abnormal cardiac pumping capacity. Whalquist et al. (2014) show that upregulation of micro-RNA25 impairs calcium handling leading to pump dysfunction, and that targeting micro-RNA25 using antisense oligonucleotides reverses pump dysfunction and improves survival in mice with heart failure.

  2. Beta-receptor activation increases sodium current in guinea pig heart

    Institute of Scientific and Technical Information of China (English)

    Hong-wei WANG; Zhi-fang YANG; Yin ZHANG; Jian-min YANG; Yuan-mou LIU; Ci-zhen LI

    2009-01-01

    Aim: To study the influence of β-receptor activation on sodium channel current and the physiological significance of increased sodium current with regard to the increased cardiac output caused by sympathetic excitation.Methods: Multiple experimental approaches, including ECG, action potential recording with conventional microelectrodes, whole-cell current measurements, single-channel recordings, and pumping-force measurements, were applied to guinea pig hearts and isolated ventricular myocytes.Results: Isoprenaline was found to dose-dependently shorten QRS waves, increase the amplitude and the Vmaxof action potentials, aug-ment the fast sodium current, and increase the occurrence frequencies and open time constants of the long-open and burst modes of the sodium channel. Increased levels of membrane-permeable cAMP have similar effects. In the presence of a calcium channel blocker, TTX reversed the increased pumping force produced by isoprenaline.Conclusion: Beta-adrenergic modulation increases the inward sodium current and accelerates the conduction velocity within the ventri-cles by changing the sodium channel modes, which might both be conducive to the synchronous contraction of the heart and enhance its pumping function.

  3. Transgenic Knockdown of Cardiac Sodium/Glucose Cotransporter 1 (SGLT1) Attenuates PRKAG2 Cardiomyopathy, Whereas Transgenic Overexpression of Cardiac SGLT1 Causes Pathologic Hypertrophy and Dysfunction in Mice

    OpenAIRE

    Ramratnam, Mohun; Sharma, Ravi K.; D'Auria, Stephen; Lee, So Jung; Wang, David; Huang, Xue Yin N.; Ahmad, Ferhaan

    2014-01-01

    Background The expression of a novel cardiac glucose transporter, SGLT1, is increased in glycogen storage cardiomyopathy secondary to mutations in PRKAG2. We sought to determine the role of SGLT1 in the pathogenesis of PRKAG2 cardiomyopathy and its role in cardiac structure and function. Methods and Results Transgenic mice with cardiomyocyte‐specific overexpression of human T400N mutant PRKAG2 cDNA (TGT400N) and transgenic mice with cardiomyocyte‐specific RNA interference knockdown of SGLT1 (...

  4. Sildenafil vs. Nitroprussiato de Sódio durante Teste de Reatividade Pulmonar pré-transplante cardíaco Sildenafil vs. sodium before nitroprusside for the pulmonary hypertension reversibility test before cardiac transplantation

    Directory of Open Access Journals (Sweden)

    Aguinaldo Figueiredo Freitas Jr

    2012-09-01

    Full Text Available FUNDAMENTO: A hipertensão pulmonar é associada ao pior prognóstico no pós-transplante cardíaco. O teste de reatividade pulmonar com Nitroprussiato de Sódio (NPS está associado a elevados índices de hipotensão arterial sistêmica, disfunção ventricular do enxerto transplantado e elevadas taxas de desqualificação para o transplante. OBJETIVO: Neste estudo, objetivou-se comparar os efeitos do Sildenafil (SIL e NPS sobre variáveis hemodinâmicas, neuro-hormonais e ecocardiográficas durante teste de reatividade pulmonar. MÉTODOS: Os pacientes foram submetidos, simultaneamente, ao cateterismo cardíaco direito, ao ecocardiograma e à dosagem de BNP e gasometria venosa, antes e após administração de NPS (1 - 2 µg/Kg/min ou SIL (100 mg, dose única. RESULTADOS: Ambos reduziram a hipertensão pulmonar, porém o nitrato promoveu hipotensão sistêmica significativa (Pressão Arterial Média - PAM: 85,2 vs. 69,8 mmHg, p BACKGROUND: Pulmonary hypertension is associated with a worse prognosis after cardiac transplantation. The pulmonary hypertension reversibility test with sodium nitroprusside (SNP is associated with a high rate of systemic arterial hypotension, ventricular dysfunction of the transplanted graft and high rates of disqualification from transplantation. OBJECTIVE: This study was aimed at comparing the effects of sildenafil (SIL and SNP on hemodynamic, neurohormonal and echocardiographic variables during the pulmonary reversibility test. METHODS: The patients underwent simultaneously right cardiac catheterization, echocardiography, BNP measurement, and venous blood gas analysis before and after receiving either SNP (1 - 2 µg/kg/min or SIL (100 mg, single dose. RESULTS: Both drugs reduced pulmonary hypertension, but SNP caused a significant systemic hypotension (mean blood pressure - MBP: 85.2 vs. 69.8 mm Hg; p < 0.001. Both drugs reduced cardiac dimensions and improved left cardiac function (SNP: 23.5 vs. 24.8%, p = 0

  5. Traumatic Tricuspid Regurgitation Following Cardiac Massage

    OpenAIRE

    Na, Sungwon; Nam, Sang Beom; Lee, Yong Kyung; Oh, Young Jun; Kwak, Young-Lan

    2007-01-01

    We report a 66-yr-old male patient who developed tricuspid regurgitation secondary to internal cardiac massage. After uneventful off-pump coronary artery bypass surgery, the subject experienced cardiac arrest in the intensive care unit. External cardiac massage was initiated and internal cardiac massage was performed eventually. A transesophageal echocardiography revealed avulsion of the anterior papillary muscle and chordae to the anterior leaflet after successful cardiopulmonary resuscitati...

  6. Sodium Azide

    Science.gov (United States)

    ... Matters What's New A - Z Index Facts About Sodium Azide What sodium azide is Sodium azide is a rapidly acting, ... give people sufficient warning of the danger. Where sodium azide is found and how it is used ...

  7. Preoperative regional cerebral oxygen saturation is a predictor of postoperative delirium in on-pump cardiac surgery patients: a prospective observational trial

    OpenAIRE

    Schoen, Julika; Meyerrose, Joscha; Paarmann, Hauke; Heringlake, Matthias; Hueppe, Michael; Berger, Klaus-Ulrich

    2011-01-01

    Introduction Postoperative delirium is an important problem in patients undergoing major surgery. Cerebral oximetry is a non-invasive method to detect imbalances in the cerebral oxygen supply/demand-ratio. Low preoperative cerebral oxygen saturation (ScO2) levels have been associated with postoperative delirium in non-cardiac surgery patients. The present prospective observational study determines the relationship between pre- and intra-operative ScO2 levels and postoperative delirium in pati...

  8. Outcome of Coronary Artery Bypass Grafts: Comparison between on Pump and off Pump

    OpenAIRE

    Rasoul Ibrahim Abdulrahman; Rezayat Parvizi

    2010-01-01

    The present study was undertaken to compare the in hospital results of coronary artery bypass graft (CABG) with (on pump) or without (off pump) cardiopulmonary bypass (CPB). Data were collected on all first-time isolated CABGs with saphenous vein and/or artery grafts at Shahid Madani Hospital in Tabriz-Iran, between 2006 and 2009. Age and clinical profile were marched between on pump and off pump group patients. Patients with concomitant cardiac operations or beating pump technique were exclu...

  9. Discovery of triazolopyridinone GS-462808, a late sodium current inhibitor (Late INai) of the cardiac Nav1.5 channel with improved efficacy and potency relative to ranolazine.

    Science.gov (United States)

    Koltun, Dmitry O; Parkhill, Eric Q; Elzein, Elfatih; Kobayashi, Tetsuya; Jiang, Robert H; Li, Xiaofen; Perry, Thao D; Avila, Belem; Wang, Wei-Qun; Hirakawa, Ryoko; Smith-Maxwell, Catherine; Wu, Lin; Dhalla, Arvinder K; Rajamani, Sridharan; Mollova, Nevena; Stafford, Brian; Tang, Jennifer; Belardinelli, Luiz; Zablocki, Jeff A

    2016-07-01

    Previously we disclosed the discovery of potent Late INa current inhibitor 2 (GS-458967, IC50 of 333nM) that has a good separation of late versus peak Nav1.5 current, but did not have a favorable CNS safety window due to high brain penetration (3-fold higher partitioning into brain vs plasma) coupled with potent inhibition of brain sodium channel isoforms (Nav1.1, 1.2, 1.3). We increased the polar surface area from 50 to 84Å(2) by adding a carbonyl to the core and an oxadiazole ring resulting in 3 GS-462808 that had lower brain penetration and serendipitously lower activity at the brain isoforms. Compound 3 has an improved CNS window (>20 rat and dog) relative to 2, and improved anti-ischemic potency relative to ranolazine. The development of 3 was not pursued due to liver lesions in 7day rat toxicology studies. PMID:27038498

  10. Pump cavitation and inducer design

    International Nuclear Information System (INIS)

    Details of past work on sodium pump development and cavitation studies executed mainly for SNR 300 were reported earlier. Among the requirements for large sodium pumps are long life (200000 hours up to 300000 hours) and small size of impeller and pump, fully meeting the process and design criteria. These criteria are the required 'Q, H, r characteristics' in combination with a low NPSH value and the avoidance of cavitation damage to the pump. The pump designer has to develop a sound hydraulic combination consisting of suction arrangement, impeller design and diffuser. On the other hand the designer is free to choose an optimal pump speed. The pump speed in its turn influences the rotor dynamic pump design and the pump drive. The introduction of the inducer as an integral part of the pump design is based on following advantages: no tip cavitation; (possible) cavitation bubbles move to the open centre due to centrifugal forces on the fluid; the head of the inducer improves the inlet conditions of the impeller. The aim of an inducer is the increase in the suction specific speed (SA value) of a pump whereby the inducer functions as a pressure source improving the impeller inlet conditions. With inducer-impeller combinations values up to SA=15000 are realistic. With the use of an inducer the overall pump sizes can be reduced with Ca. 30%. Pumps commonly available have SA values up to a maximum of ca. 10000. A development programme was executed for SNR 300 in order to reach an increase of the suction specific speed of the impeller from SA 8200 to SA 11000. Further studies to optimize pumps design for the follow up line introduced the 'inducer acting as a pre-impeller' development. This programme was executed in the period 1979-1981. At the FDO premises a scale 1 2.8 inducer impeller combination with a suction specific speed SA=15000 was developed, constructed and tested at the water test rig. This water test rig is equipped with a perspex pipe allowing also visualisation

  11. Late cardiac sodium current can be assessed using automated patch-clamp [v1; ref status: indexed, http://f1000r.es/4kj

    Directory of Open Access Journals (Sweden)

    Morgan Chevalier

    2014-10-01

    Full Text Available The cardiac late Na+ current is generated by a small fraction of voltage-dependent Na+ channels that undergo a conformational change to a burst-gating mode, with repeated openings and closures during the action potential (AP plateau. Its magnitude can be augmented by inactivation-defective mutations, myocardial ischemia, or prolonged exposure to chemical compounds leading to drug-induced (di-long QT syndrome, and results in an increased susceptibility to cardiac arrhythmias. Using CytoPatch™ 2 automated patch-clamp equipment, we performed whole-cell recordings in HEK293 cells stably expressing human Nav1.5, and measured the late Na+ component as average current over the last 100 ms of 300 ms depolarizing pulses to -10 mV from a holding potential of -100 mV, with a repetition frequency of 0.33 Hz. Averaged values in different steady-state experimental conditions were further corrected by the subtraction of current average during the application of tetrodotoxin (TTX 30 μM. We show that ranolazine at 10 and 30 μM in 3 min applications reduced the late Na+ current to 75.0 ± 2.7% (mean ± SEM, n = 17 and 58.4 ± 3.5% (n = 18 of initial levels, respectively, while a 5 min application of veratridine 1 μM resulted in a reversible current increase to 269.1 ± 16.1% (n = 28 of initial values. Using fluctuation analysis, we observed that ranolazine 30 μM decreased mean open probability p from 0.6 to 0.38 without modifying the number of active channels n, while veratridine 1 μM increased n 2.5-fold without changing p. In human iPSC-derived cardiomyocytes, veratridine 1 μM reversibly increased APD90 2.12 ± 0.41-fold (mean ± SEM, n = 6. This effect is attributable to inactivation removal in Nav1.5 channels, since significant inhibitory effects on hERG current were detected at higher concentrations in hERG-expressing HEK293 cells, with a 28.9 ± 6.0% inhibition (mean ± SD, n = 10 with 50 μM veratridine.      

  12. Sodium content and sodium efflux of mononuclear leucocytes from young subjects at increased risk of developing essential hypertension

    DEFF Research Database (Denmark)

    Pedersen, K E; Nielsen, J R; Klitgaard, N A;

    1990-01-01

    Mononuclear leucocytes were used as a cellular model for the in vitro measurements of volume, sodium and potassium content, sodium efflux rate constants and absolute sodium efflux in order to assess any cellular changes in young men at increased risk of developing essential hypertension, and to a...... the sodium-potassium pump seems activated....

  13. Cardiac glycoside-like structure and function of 5 beta,14 beta-pregnanes

    International Nuclear Information System (INIS)

    5 beta-Reduction and 14 beta-substitution convert the planar progesterone molecule to the cardiac glycoside configuration--A and D rings of the steroid moiety are bent toward the alpha-face relative to the B and C rings. Potency of the 5 beta,14 beta-derivative in a [3H]ouabain binding assay or its ability to inhibit the sodium pump in red blood cells is enhanced by 3 beta-hydroxylation, 20 beta-hydroxylation, and 3 beta-glycosidation. Synthesis of 14,20 beta-dihydroxy-3 beta-(beta-D-glucopyranosyloxy)- 5 beta,14 beta-pregnane from digitoxin is described. The glucoside is 1/20 as potent as ouabain and elicits prominent, sustained, positive inotropy in isolated cardiac muscle

  14. Centrifugal pumps

    CERN Document Server

    Anderson, HH

    1981-01-01

    Centrifugal Pumps describes the whole range of the centrifugal pump (mixed flow and axial flow pumps are dealt with more briefly), with emphasis on the development of the boiler feed pump. Organized into 46 chapters, this book discusses the general hydrodynamic principles, performance, dimensions, type number, flow, and efficiency of centrifugal pumps. This text also explains the pumps performance; entry conditions and cavitation; speed and dimensions for a given duty; and losses. Some chapters further describe centrifugal pump mechanical design, installation, monitoring, and maintenance. The

  15. Assembly of the Cardiac Intercalated Disk during Pre- and Postnatal Development of the Human Heart

    Science.gov (United States)

    Vreeker, Arnold; van Stuijvenberg, Leonie; Hund, Thomas J.; Mohler, Peter J.; Nikkels, Peter G. J.; van Veen, Toon A. B.

    2014-01-01

    Background In cardiac muscle, the intercalated disk (ID) at the longitudinal cell-edges of cardiomyocytes provides as a macromolecular infrastructure that integrates mechanical and electrical coupling within the heart. Pathophysiological disturbance in composition of this complex is well known to trigger cardiac arrhythmias and pump failure. The mechanisms underlying assembly of this important cellular domain in human heart is currently unknown. Methods We collected 18 specimens from individuals that died from non-cardiovascular causes. Age of the specimens ranged from a gestational age of 15 weeks through 11 years postnatal. Immunohistochemical labeling was performed against proteins comprising desmosomes, adherens junctions, the cardiac sodium channel and gap junctions to visualize spatiotemporal alterations in subcellular location of the proteins. Results Changes in spatiotemporal localization of the adherens junction proteins (N-cadherin and ZO-1) and desmosomal proteins (plakoglobin, desmoplakin and plakophilin-2) were identical in all subsequent ages studied. After an initial period of diffuse and lateral labelling, all proteins were fully localized in the ID at approximately 1 year after birth. Nav1.5 that composes the cardiac sodium channel and the gap junction protein Cx43 follow a similar pattern but their arrival in the ID is detected at (much) later stages (two years for Nav1.5 and seven years for Cx43, respectively). Conclusion Our data on developmental maturation of the ID in human heart indicate that generation of the mechanical junctions at the ID precedes that of the electrical junctions with a significant difference in time. In addition arrival of the electrical junctions (Nav1.5 and Cx43) is not uniform since sodium channels localize much earlier than gap junction channels. PMID:24733085

  16. Sodium Phosphate

    Science.gov (United States)

    Sodium phosphate is used in adults 18 years of age or older to empty the colon (large intestine, bowel) ... view of the walls of the colon. Sodium phosphate is in a class of medications called saline ...

  17. Sodium Oxybate

    Science.gov (United States)

    Sodium oxybate is used to prevent attacks of cataplexy (episodes of muscle weakness that begin suddenly and ... urge to sleep during daily activities, and cataplexy). Sodium oxybate is in a class of medications called ...

  18. Sodium Test

    Science.gov (United States)

    ... be limited. Home Visit Global Sites Search Help? Sodium Share this page: Was this page helpful? Also known as: Na Formal name: Sodium Related tests: Chloride , Bicarbonate , Potassium , Electrolytes , Osmolality , Basic ...

  19. Sodium Oxybate

    Science.gov (United States)

    ... sodium oxybate.Sodium oxybate is not available at retail pharmacies. A special program is in place to ... Drug Administration's (FDA) MedWatch Adverse Event Reporting program online (http://www.fda.gov/Safety/MedWatch) or by ...

  20. Design and Commissioning Test of WKN Sodium Thermodynamic Test Loop

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    In the research of fast reactor a sodium thermodynamic test loop was designed and commissioned. Its highest operating temperature is 700℃, after the sodium is passed the cooler, the temperature of the sodium can be reduced to 300 ℃; the sodium flow is 0.2 m3/h. The loop consists of sodium electromagnetic pump, sodium flow meter, two groups of heater, two groups of cooler, surge tank, sodium vapor trap, diffusion cold trap, sodium transportation tank, electric control panel and microprocessor. It has two experimental bypass loops for research of heat transfer

  1. 机器人外科手术系统体外循环心脏手术的初步经验%Total endoscopic robot-assisted on-pump cardiac surgery: preliminary experience with robot-assisted surgery

    Institute of Scientific and Technical Information of China (English)

    魏来; 黄麒; 王春生; 沈金强; 夏利民; 罗红; 廖庆武; 胡克俭; 王萍; 徐竹静

    2011-01-01

    Objective To introduce our preliminary experience in total endoscopic robot-assisted onpump cardiac surgery with da Vinci system. Methods Five patients with mitral insufficiency (MI) and five patients with atrial septai defect (ASD) underwent on-pump cardiac surgical procedures using da Vinci S system from Aug. 2010 to Dec. 2010. After double-lumen endotracheal intubation and intravenous inhalation anesthesia,the peripheral extracorporeal circulation was established with femoral arterial cannula, femoral venous cannula and right internal jugular venous cannula. Through a 3 cm-length working-port and other three 0.8 cm-length mini-ports,the total endoscopic robotic-assisted operations (including mitral valve repair and ASD repair) were performed.Results All procedures were successfully performed without incision expansion or converting to sternotomy.Transesophageal echocardiography (TEE) showed no moderate or severe .m. itral valve regurgitation or atrial septal shunt. There were no in-hospital death or post-operative complications. The patients recovered quickly with less bleeding and shorter hospital stay. All patients were followed-up for 1 - 3 months and had satisfactory TEE results.Conclusion The da Vinci robotic surgery system is safe and reliable for cardiac surgery, with satisfactory outcome, mini-invasiveness, rapid recovery and bright future. (Shanghai Med J, 2011, 34: 38-42)%目的 介绍复旦大学附属中山医院应用达芬奇S机器人外科手术系统辅助开展全内镜体外循环心脏手术的初步经验.方法 2010年8-12月在达芬奇S机器人外科手术系统辅助下完成全内镜二尖瓣成形术5例,房间隔缺损修补术5例.全组患者均采用双腔气管插管、静脉吸入复合麻醉,经股动脉、股静脉及右颈内静脉插管建立外周体外循环.于右胸第4肋间隙作3 cm工作孔,右胸第3、4、6肋间隙分别作0.8 cm器械孔,由术者操控机械臂完成全内镜下心内直视手术.结果 所有

  2. Cardiac Hypertrophy: A Review on Pathogenesis and Treatment

    OpenAIRE

    Ankur Rohilla; Praveen Kumar; Seema Rohilla; Ashok Kushnoor

    2012-01-01

    Cardiac hypertrophy has been considered as an important risk factor for cardiac morbidity and mortality whose prevalence has increased during the last few decades. Cardiac hypertrophy, a disease associated with the myocardium, is characterized by thickening of ventricle wall of heart and consequent reduction in the contracting ability of heart to pump the blood. Cardiac hypertrophy has been divided into two types, i.e. physiological and pathological hypertrophy. The exercise-induced increase ...

  3. Some techniques for sodium removal in CIAE

    International Nuclear Information System (INIS)

    In this paper the experiment and application on sodium removal and sodium disposal are presented. Steam-nitrogen process was used in CIAE for cleaning cold traps, sodium vapor traps, a sodium tank. Atomized water-nitrogen process was used for cleaning dummy fuel assembly for CEFR and a sintered stainless steel filter. Sprinkle process was used for cleaning some tubes. Bultylcellosolve was used for cleaning sintered stainless steel filter and sodium flow measurement device. Ethanol alcohol was used for cleaning electromagnetic pump. Paraffin, transformer-oil or their mixture was used for cleaning sodium valves, a sodium vapor trap and sodium-potassium alloy absorber. A small sintered stainless steel filter was distillated in vacuum. A simple sodium disposal device has been served for several years in CIA.E. It can dispose about 10 Kg sodium each time and the disposal process is no-aerosol. It operates in open air for non-radioactive sodium. In recent years a small sodium cleaning plant has been built. It can use atomized water, steam or organic alcohol to removal of sodium. The LAVEL cleaning plant and SLAPSO cleaning plant were introduced from Italy. And CEFR preliminary design on sodium cleaning for spent fuel assembly and on sodium removal-decontamination for large reactor components is introduced. Vapour-nitrogen process is planned to use in them. (author)

  4. Heat pumps

    CERN Document Server

    Macmichael, DBA

    1988-01-01

    A fully revised and extended account of the design, manufacture and use of heat pumps in both industrial and domestic applications. Topics covered include a detailed description of the various heat pump cycles, the components of a heat pump system - drive, compressor, heat exchangers etc., and the more practical considerations to be taken into account in their selection.

  5. Heat pumps

    CERN Document Server

    Brodowicz, Kazimierz; Wyszynski, M L; Wyszynski

    2013-01-01

    Heat pumps and related technology are in widespread use in industrial processes and installations. This book presents a unified, comprehensive and systematic treatment of the design and operation of both compression and sorption heat pumps. Heat pump thermodynamics, the choice of working fluid and the characteristics of low temperature heat sources and their application to heat pumps are covered in detail.Economic aspects are discussed and the extensive use of the exergy concept in evaluating performance of heat pumps is a unique feature of the book. The thermodynamic and chemical properties o

  6. Hidden Sodium

    Centers for Disease Control (CDC) Podcasts

    2013-03-04

    In this podcast, learn about reducing sodium intake by knowing what to eat and the main sources of sodium in the diet. It's important for a healthy lifestyle.  Created: 3/4/2013 by National Center for Chronic Disease Prevention and Health Promotion (NCCDPHP).   Date Released: 3/4/2013.

  7. Development of sodium technology

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Sung Tai; Nam, H. Y.; Choi, Y. D. [and others

    2000-05-01

    The objective of present study is to produce the experimental data for development and verification of computer codes for development of LMR and to develop the preliminary technologies for the future large scale verification experiments. A MHD experimental test loop has been constructed for the quantitative analysis of the effect of magnetic field on the sodium flow and experiments are carried out for three EM pumps. The previous pressure drop correlations are evaluated using the experimental data obtained from the pressure drop experiment in a 19-pin fuel assembly with wire spacer. An dimensionless variable is proposed to describe the amplitude and frequency of the fluctuation of free surface using the experimental data obtained from free surface experimental apparatus and an empirical correlation is developed using this dimensionless variable. An experimental test loop is constructed to measure the flow characteristics in IHX shell side and the local pressure drop in fuel assembly, and to test the vibration behaviour of fuel pins due to flow induced vibration. The sodium two-phase flow measuring technique using the electromagnetic flowmeter is developed and the sodium differential pressure drop measuring technique using the method of direct contact of sodium and oil is established. The work on the analysis of sodium fire characteristics and produce data for vlidation of computer code is performed. Perfect reopen time of self plugged leak path was observed to be about 130 minutes after water leak initiation. Reopen shape of a specimen appeared to be double layer of circular type, and reopen size of this specimen surface was about 2mm diameter on sodium side. In small water leakage experiments, the following correlation equation about the reopen time between sodium temperature and initial leak rate was obtained, {tau}{sub c} = {delta}{center_dot}g{sup -0.83}{center_dot}10{sup (3570/T{sub Na}-3.34)}, in 400-500 deg C of liquid sodium atmosphere. The characteristics

  8. Development of sodium technology

    International Nuclear Information System (INIS)

    The objective of present study is to produce the experimental data for development and verification of computer codes for development of LMR and to develop the preliminary technologies for the future large scale verification experiments. A MHD experimental test loop has been constructed for the quantitative analysis of the effect of magnetic field on the sodium flow and experiments are carried out for three EM pumps. The previous pressure drop correlations are evaluated using the experimental data obtained from the pressure drop experiment in a 19-pin fuel assembly with wire spacer. An dimensionless variable is proposed to describe the amplitude and frequency of the fluctuation of free surface using the experimental data obtained from free surface experimental apparatus and an empirical correlation is developed using this dimensionless variable. An experimental test loop is constructed to measure the flow characteristics in IHX shell side and the local pressure drop in fuel assembly, and to test the vibration behaviour of fuel pins due to flow induced vibration. The sodium two-phase flow measuring technique using the electromagnetic flowmeter is developed and the sodium differential pressure drop measuring technique using the method of direct contact of sodium and oil is established. The work on the analysis of sodium fire characteristics and produce data for vlidation of computer code is performed. Perfect reopen time of self plugged leak path was observed to be about 130 minutes after water leak initiation. Reopen shape of a specimen appeared to be double layer of circular type, and reopen size of this specimen surface was about 2mm diameter on sodium side. In small water leakage experiments, the following correlation equation about the reopen time between sodium temperature and initial leak rate was obtained, τc = δ·g-0.83·10(3570/TNa-3.34), in 400-500 deg C of liquid sodium atmosphere. The characteristics of pressure propagation and gas flow, and pressure

  9. Dietary sodium

    DEFF Research Database (Denmark)

    Graudal, Niels

    2015-01-01

    The 2013 Institute of Medicine (IOM) report "Sodium Intake in Populations: Assessment of Evidence" did not support the current recommendations of the IOM and the American Heart Association (AHA) to reduce daily dietary sodium intake to below 2,300 mg. The report concluded that the population......-based health outcome evidence was not sufficient to define a safe upper intake level for sodium. Recent studies have extended this conclusion to show that a sodium intake below 2,300 mg/day is associated with increased mortality. In spite of this increasing body of evidence, the AHA, Centers for Disease...... Control (CDC), other public health advisory bodies, and major medical journals have continued to support the current policy of reducing dietary sodium....

  10. Pumping life

    DEFF Research Database (Denmark)

    Sitsel, Oleg; Dach, Ingrid; Hoffmann, Robert Daniel

    2012-01-01

    The name PUMPKIN may suggest a research centre focused on American Halloween traditions or the investigation of the growth of vegetables – however this would be misleading. Researchers at PUMPKIN, short for Centre for Membrane Pumps in Cells and Disease, are in fact interested in a large family of...... membrane proteins: P-type ATPase pumps. This article takes the reader on a tour from Aarhus to Copenhagen, from bacteria to plants and humans, and from ions over protein structures to diseases caused by malfunctioning pump proteins. The magazine Nature once titled work published from PUMPKIN ‘Pumping ions......’. Here we illustrate that the pumping of ions means nothing less than the pumping of life....

  11. Centrifugal pumps

    CERN Document Server

    Gülich, Johann Friedrich

    2014-01-01

    This book gives an unparalleled, up-to-date, in-depth treatment of all kinds of flow phenomena encountered in centrifugal pumps including the complex interactions of fluid flow with vibrations and wear of materials. The scope includes all aspects of hydraulic design, 3D-flow phenomena and partload operation, cavitation, numerical flow calculations, hydraulic forces, pressure pulsations, noise, pump vibrations (notably bearing housing vibration diagnostics and remedies), pipe vibrations, pump characteristics and pump operation, design of intake structures, the effects of highly viscous flows, pumping of gas-liquid mixtures, hydraulic transport of solids, fatigue damage to impellers or diffusers, material selection under the aspects of fatigue, corrosion, erosion-corrosion or hydro-abrasive wear, pump selection, and hydraulic quality criteria. As a novelty, the 3rd ed. brings a fully analytical design method for radial impellers, which eliminates the arbitrary choices inherent to former design procedures. The d...

  12. Cardiac rehabilitation

    Science.gov (United States)

    ... attack or other heart problem. You might consider cardiac rehab if you have had: Heart attack Coronary heart disease (CHD) Heart failure Angina (chest pain) Heart or heart valve surgery Heart transplant Procedures such as angioplasty and stenting In some ...

  13. Cardiac Rehabilitation

    Science.gov (United States)

    Cardiac rehabilitation (rehab) is a medically supervised program to help people who have A heart attack Angioplasty or coronary artery bypass grafting for coronary heart disease A heart valve repair or replacement A ...

  14. Cardiac sarcoidosis

    OpenAIRE

    Costello BT; Nadel J.; Taylor AJ

    2016-01-01

    Benedict T Costello,1,2 James Nadel,3 Andrew J Taylor,1,21Department of Cardiovascular Medicine, The Alfred Hospital, 2Baker IDI Heart and Diabetes Research Institute, Melbourne, VIC, 3School of Medicine, University of Notre Dame, Sydney, NSW, Australia Abstract: Cardiac sarcoidosis is a rare but life-threatening condition, requiring a high degree of clinical suspicion and low threshold for investigation to make the diagnosis. The cardiac manifestations include heart failure, conducting syst...

  15. Physiological and pathological cardiac hypertrophy.

    Science.gov (United States)

    Shimizu, Ippei; Minamino, Tohru

    2016-08-01

    The heart must continuously pump blood to supply the body with oxygen and nutrients. To maintain the high energy consumption required by this role, the heart is equipped with multiple complex biological systems that allow adaptation to changes of systemic demand. The processes of growth (hypertrophy), angiogenesis, and metabolic plasticity are critically involved in maintenance of cardiac homeostasis. Cardiac hypertrophy is classified as physiological when it is associated with normal cardiac function or as pathological when associated with cardiac dysfunction. Physiological hypertrophy of the heart occurs in response to normal growth of children or during pregnancy, as well as in athletes. In contrast, pathological hypertrophy is induced by factors such as prolonged and abnormal hemodynamic stress, due to hypertension, myocardial infarction etc. Pathological hypertrophy is associated with fibrosis, capillary rarefaction, increased production of pro-inflammatory cytokines, and cellular dysfunction (impairment of signaling, suppression of autophagy, and abnormal cardiomyocyte/non-cardiomyocyte interactions), as well as undesirable epigenetic changes, with these complex responses leading to maladaptive cardiac remodeling and heart failure. This review describes the key molecules and cellular responses involved in physiological/pathological cardiac hypertrophy. PMID:27262674

  16. Adopt Various Teaching Methods: Giving Lessons on the Basic Function of Cell Based on Teaching of Sodium Potassium Pump%采用多种教学法——以钠钾泵为主线讲好细胞基本功能的体会

    Institute of Scientific and Technical Information of China (English)

    唐云; 张燕辉

    2012-01-01

    When giving lessons on the basic function of physiology cells, the author teaches complex and abstract bioelectric phenomenon based on sodium potassium pump by using various teaching methods like using multi-media courseware.%在生理学细胞的基本功能这一章节的授课中,以钠钾泵为主线,采用演示动态多媒体课件为主的多种教学手段,将抽象、复杂的细胞生物电现象,讲得比较透彻和直观.

  17. Prevalence of cardiac dyssynchrony and correlation with atrio-ventricular block and QRS width in dilated cardiomyopathy

    DEFF Research Database (Denmark)

    Anzouan-Kacou, J B; Ncho-Mottoh, M P; Konin, C;

    2012-01-01

    Cardiac dyssynchrony causes disorganised cardiac contraction, delayed wall contraction and reduced pumping efficiency. We aimed to assess the prevalence of different types of dyssynchrony in patients with dilated cardiomyopathy (DCM), and to establish the correlation between atrio-ventricular block...

  18. Liquid-metal pumps for large-scale breeder-reactor plant (prototype pump)

    Energy Technology Data Exchange (ETDEWEB)

    Lindsay, M. (comp.)

    1976-07-01

    This report presents the recommended pump design for use in Large Scale Liquid Metal Fast Breeder Reactor plants. The base design for the pump will circulate 127,000 GPM of liquid sodium at temperatures up to 850/sup 0/F and with a total discharge head at the design point of 500 feet Na with an impeller that is 40 feet below the sodium seal. The pump design is predicated on developing an impeller design which will have a suction specific speed (S/sub n/) of about 20,000 with 20 feet NPSH available, which will result in a pump speed of 530 RPM at design conditions. The design is based on the technology developed in the design and fabrication of FFTF pumps, the design efforts for the Clinch River Breeder Reactor Pump design study and other technology.

  19. Experience on sodium removal from various components

    International Nuclear Information System (INIS)

    Since 1970, OEC (O-arai Engineering Center) has been Investigating the following methods for removal of sodium from the components of sodium plants: steam cleaning for the 50 MW Steam Generator, secondary proto-type pump of 'JOYO' and Dummy fuel assembly of 'JOYO', alcohol cleaning for Sector Model of Intermediate Heat Exchanger (IHX) of 'JOYO', a sector model of Sodium-to-Air cooler of 'JOYO' and a proto-type isolation valve of 'JOYO' and cleaning by vacuumization at high temperature for Regenerative Heat Exchanger. This report describes the outline of the Sodium Disposal Facility and experience of sodium removal processing on the 50 MW Steam Generator, the crevices of the experimental sub-assemblies, the Fuel Handling Machine of 'MONJU' and the Regenerative Heat Exchanger of the Sodium Flow Test Facility. Through these experiences it was noted that, (1) Removal of sodium from crevices such as in bolted joints are very difficult. (2) Consideration is needed in the removal process where material damage might occur from the generation of hydro-oxides. (3) Some detection device to tell the completion of sodium removal as well as the end of reaction is required. (4) Requalification rules should be clarified. Efforts in this direction have been made in the case of a 'JOYO' prototype pump by reinstalling it after sodium removal five times. (author)

  20. Fondaparinux sodium.

    Science.gov (United States)

    Keam, Susan J; Goa, Karen L

    2002-01-01

    black triangle Fondaparinux sodium, a selective factor Xa inhibitor, is the first in a new class of antithrombotics. It binds selectively with high affinity to antithrombin III and specifically catalyses the inactivation of factor Xa. The elimination half-life of fondaparinux sodium permits once daily treatment. black triangle A randomised, double-blind, parallel-group, dose-ranging, multicentre phase IIb study in 933 eligible patients established that a subcutaneous dose of between 1.5 and 3mg of fondaparinux sodium has the optimum efficacy and safety profile for prophylaxis of venous thromboembolism in patients undergoing major orthopaedic surgery. black triangle Fondaparinux sodium, given to more than 3600 patients undergoing major orthopaedic surgery who participated in prospective, randomised, double-blind, multicentre phase III clinical trials, significantly reduced the incidence of venous thromboembolism, with an overall risk reduction of 55.2% compared with enoxaparin. black triangle Fondaparinux sodium was well tolerated by patients undergoing major orthopaedic surgery, and at the recommended clinical dose of 2.5mg has a similar tolerability profile, including bleeding events, to standard enoxaparin regimens. Fondaparinux sodium has not been reported to cause antibody-induced thrombocytopenia. PMID:12109927

  1. Technological Solutions for Cardiac Surgery in the Elderly

    OpenAIRE

    Rony-Reuven Nir; Gil Bolotin

    2013-01-01

    The current review addresses contemporary technological advances in cardiac surgery performed on octogenarian patients, namely off-pump coronary artery bypass grafting (CABG), proximal anastomosis device, routine use of intraoperative epiaortic ultrasound, proximal anastomosis without clamping, transcatheter aortic valve implantation (TAVI), and brain protection during cardiac surgery.

  2. Red blood cell sodium transport in patients with cirrhosis

    DEFF Research Database (Denmark)

    Henriksen, Ulrik Lütken; Kiszka-Kanowitz, Marianne; Bendtsen, Flemming;

    2016-01-01

    Patients with advanced cirrhosis have abnormal sodium homoeostasis. The study was undertaken to quantify the sodium transport across the plasma membrane of red blood cells (RBC) in patients with cirrhosis. RBC efflux and influx of sodium were studied in vitro with tracer (22) Na(+) according to....... Increased RBC sodium efflux is especially related to ouabain-sensitive, furosemide-insensitive transport and thus most likely due to upregulated activity of the sodium-potassium pump. The study gives no evidence to an altered intracellular/extracellular sodium ratio or to a reduced fractional furosemide...

  3. Cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc [Charite - Universitaetsmedizin Berlin (Germany). Inst. fuer Radiologie

    2011-07-01

    Computed tomography of the heart has become a highly accurate diagnostic modality that is attracting increasing attention. This extensively illustrated book aims to assist the reader in integrating cardiac CT into daily clinical practice, while also reviewing its current technical status and applications. Clear guidance is provided on the performance and interpretation of imaging using the latest technology, which offers greater coverage, better spatial resolution, and faster imaging. The specific features of scanners from all four main vendors, including those that have only recently become available, are presented. Among the wide range of applications and issues to be discussed are coronary artery bypass grafts, stents, plaques, and anomalies, cardiac valves, congenital and acquired heart disease, and radiation exposure. Upcoming clinical uses of cardiac CT, such as plaque imaging and functional assessment, are also explored. (orig.)

  4. Cardiac echinococcosis

    Directory of Open Access Journals (Sweden)

    Ivanović-Krstić Branislava A.

    2002-01-01

    Full Text Available Cardiac hydatid disease is rare. We report on an uncommon hydatid cyst localized in the right ventricular wall, right atrial wall tricuspid valve left atrium and pericard. A 33-year-old woman was treated for cough, fever and chest pain. Cardiac echocardiograpic examination revealed a round tumor (5.8 x 4 cm in the right ventricular free wall and two smaller cysts behind that tumor. There were cysts in right atrial wall and tricuspidal valve as well. Serologic tests for hydatidosis were positive. Computed tomography finding was consistent with diagnosis of hydatid cyst in lungs and right hylar part. Surgical treatment was rejected due to great risk of cardiac perforation. Medical treatment with albendazole was unsuccessful and the patient died due to systemic hydatid involvement of the lungs, liver and central nervous system.

  5. Neuromuscular blockade in cardiac surgery: An update for clinicians

    OpenAIRE

    Hemmerling Thomas; Russo Gianluca; Bracco David

    2008-01-01

    There have been great advancements in cardiac surgery over the last two decades; the widespread use of off-pump aortocoronary bypass surgery, minimally invasive cardiac surgery, and robotic surgery have also changed the face of cardiac anaesthesia. The concept of "Fast-track anaesthesia" demands the use of nondepolarising neuromuscular blocking drugs with short duration of action, combining the ability to provide (if necessary) sufficiently profound neuromuscular blockade during surgery and i...

  6. Cardiac sarcoidosis

    Science.gov (United States)

    Smedema, J.P.; Zondervan, P.E.; van Hagen, P.; ten Cate, F.J.; Bresser, P.; Doubell, A.F.; Pattynama, P.; Hoogsteden, H.C.; Balk, A.H.M.M.

    2002-01-01

    Sarcoidosis is a multi-system granulomatous disorder of unknown aetiology. Symptomatic cardiac involvement occurs in approximately 5% of patients. The prevalence of sarcoidosis in the Netherlands is unknown, but estimated to be approximately 20 per 100,000 population (3200 patients). We report on five patients who presented with different manifestations of cardiac sarcoidosis, and give a brief review on the current management of this condition. Magnetic Resonance Imaging (MRI) can be of great help in diagnosing this condition as well as in the follow-up of the response to therapy. ImagesFigure 1Figure 2Figure 3Figure 4Figure 5Figure 6 PMID:25696121

  7. Jet Pump

    OpenAIRE

    Wærp, Nils Petter

    2010-01-01

    The aim of this project is to investigate how an artificial lift method in the oil industry works,and to compare its performance with other pump systems. Jet pumps are initially used in the oil industry for artificial lift and thus in order to do so one needs a good understanding of themechanics to predict the jet pumps’ performance. The project will begin with a review of how the jet pump operates, aiming to give the reader an insight and overview into the field of an artificial lift method....

  8. Electrokinetic pump

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Kamlesh D. (Dublin, CA)

    2007-11-20

    A method for altering the surface properties of a particle bed. In application, the method pertains particularly to an electrokinetic pump configuration where nanoparticles are bonded to the surface of the stationary phase to alter the surface properties of the stationary phase including the surface area and/or the zeta potential and thus improve the efficiency and operating range of these pumps. By functionalizing the nanoparticles to change the zeta potential the electrokinetic pump is rendered capable of operating with working fluids having pH values that can range from 2-10 generally and acidic working fluids in particular. For applications in which the pump is intended to handle highly acidic solutions latex nanoparticles that are quaternary amine functionalized can be used.

  9. Cardiac Pacemakers

    International Nuclear Information System (INIS)

    A complete survey of physiological biophysical,clinical and engineering aspects of cardiac facing,including the history and an assessment of possible future developments.Among the topics studied are: pacemakers, energy search, heart stimulating with pacemakers ,mathematical aspects of the electric cardio stimulation chronic, pacemaker implants,proceeding,treatment and control

  10. Sodium Bicarbonate Therapy in Patients with Metabolic Acidosis

    OpenAIRE

    Adeva-Andany, María M.; Carlos Fernández-Fernández; David Mouriño-Bayolo; Elvira Castro-Quintela; Alberto Domínguez-Montero

    2014-01-01

    Metabolic acidosis occurs when a relative accumulation of plasma anions in excess of cations reduces plasma pH. Replacement of sodium bicarbonate to patients with sodium bicarbonate loss due to diarrhea or renal proximal tubular acidosis is useful, but there is no definite evidence that sodium bicarbonate administration to patients with acute metabolic acidosis, including diabetic ketoacidosis, lactic acidosis, septic shock, intraoperative metabolic acidosis, or cardiac arrest, is beneficial ...

  11. Cardiac rhabdomyosarcoma

    OpenAIRE

    Chlumský, Jaromír; Holá, Dana; Hlaváček, Karel; Michal, Michal; Švec, Alexander; Špatenka, Jaroslav; Dušek, Jan

    2001-01-01

    Cardiac sarcoma is a very rare neoplasm and is difficult to diagnose. The case of a 51-year-old man with a left atrial tumour, locally recurrent three months after its surgical removal, is presented. Computed tomography showed metastatic spread to the lung parenchyma. On revised histology, the mass extirpated was a sarcoma. Because of the metastatic spread, further therapy was symptomatic only; the patient died 15 months after the first manifestation of his problems. Immunohistochemical stain...

  12. Cardiac Calcification

    Directory of Open Access Journals (Sweden)

    Morteza Joorabian

    2011-05-01

    Full Text Available There is a spectrum of different types of cardiac"ncalcifications with the importance and significance"nof each type of cardiac calcification, especially"ncoronary artery calcification. Radiologic detection of"ncalcifications within the heart is quite common. The"namount of coronary artery calcification correlates"nwith the severity of coronary artery disease (CAD."nCalcification of the aortic or mitral valve may indicate"nhemodynamically significant valvular stenosis."nMyocardial calcification is a sign of prior infarction,"nwhile pericardial calcification is strongly associated"nwith constrictive pericarditis. A spectrum of different"ntypes of cardiac calcifications (linear, annular,"ncurvilinear,... could be seen in chest radiography and"nother imaging modalities. So a carful inspection for"ndetection and reorganization of these calcifications"nshould be necessary. Numerous modalities exist for"nidentifying coronary calcification, including plain"nradiography, fluoroscopy, intravascular ultrasound,"nMRI, echocardiography, and conventional, helical and"nelectron-beam CT (EBCT. Coronary calcifications"ndetected on EBCT or helical CT can be quantifie,"nand a total calcification score (Cardiac Calcification"nScoring may be calculated. In an asymptomatic"npopulation and/or patients with concomitant risk"nfactors like diabetes mellitus, determination of the"npresence of coronary calcifications identifies the"npatients at risk for future myocardial infarction and"ncoronary artery disease. In patients without coronary"ncalcifications, future cardiovascular events could"nbe excluded. Therefore, detecting and recognizing"ncalcification related to the heart on chest radiography"nand other imaging modalities such as fluoroscopy, CT"nand echocardiography may have important clinical"nimplications.

  13. Inducer pumps for liquid metal reactor plants

    International Nuclear Information System (INIS)

    Pumps proposed for liquid metal reactor plants typically use centrifugal impellers as the rotating element and are required to maintain a relatively low speed to keep the suction specific speed low enough to operate at the available net positive suction head (HPSH) and to avoid cavitation damage. These low speeds of operation require that the pump diameter increase and/or multiple stages be used to achieve the design head. This frequently results in a large, heavy, complex pump design. In addition, the low speed results in a larger drive motor size so that the resultant penalty to the plant designer is multiplied. The heavier pump can also result in further complications as, e.g., the difficulty in maintaining the first critical speed sufficiently above the pump operating range to provide margin for rotor dynamic stability. To overcome some of these disadvantages, it was proposed the use of inducer pumps for Liquid Metal Fast Breeder Reactor (LMFBR) plants. This paper discusses some of the advantages of the inducer pump and the development history of designing and testing these pumps both in water and sodium. The inducer pump is seen to be a sound concept with a strong technology base derived from the aerospace and ship propulsion industries. The superior suction performance capability of the inducer offers significant system design advantages, primarily a smaller, lighter weight, less complex pump design with resulting saving in cost. Extensive testing of these pumps has been conducted in both sodium and water to demonstrate the long-life capability with no cavitation damage occurring in those designs based on Rockwell's current design criteria. These tests have utilized multiple inspection and measurement approaches to accurately assess and identify any potential for cavitation damage, and these approaches have all concluded that no damage is occurring. Therefore, it is concluded that inducer pumps can be safely designed for long life operation in sodium with

  14. Test Your Sodium Smarts

    Science.gov (United States)

    ... You may be surprised to learn how much sodium is in many foods. Sodium, including sodium chloride ... foods with little or no salt. Test your sodium smarts by answering these 10 questions about which ...

  15. Insulin pumps.

    Science.gov (United States)

    Pickup, J

    2011-02-01

    The last year has seen a continued uptake of insulin pump therapy in most countries. The USA is still a leader in pump use, with probably some 40% of type 1 diabetic patients on continuous subcutaneous insulin infusion (CSII), but the large variation in usage within Europe remains, with relatively high use (> 15%) in, for example, Norway, Austria, Germany and Sweden and low use (companies or funding from national health services, the availability of sufficient diabetes nurse educators and dietitians trained in pump procedures, and clear referral pathways for the pump candidate from general practitioner or general hospital to specialist pump centre. There are now several comprehensive national guidelines on CSII use (see ATTD Yearbook 2009) but more work needs to be done in unifying uptake and ensuring all those who can benefit do so. Technology developments recently include increasing use of pumps with continuous glucose monitoring (CGM) connectivity (see elsewhere in this volume) and the emergence of numerous manufacturers developing so-called 'patch pumps', often for the type 2 diabetes market. Interestingly, the evidence base for CSII in this group is not well established, and for this reason the selected papers on CSII in this section include several in this area. The use of CSII in diabetic pregnancy is a long-established practice, in spite of the lack of evidence that it is superior to multiple daily injections (MDI), and few randomised controlled trials have been done in recent years. Several papers in this field this year continue the debate about the usefulness of CSII in diabetic pregnancy and are reviewed here. It is pleasing to see more research on the psychosocial aspects of CSII during the year, both from the point of view of how psychological beliefs influence outcomes on CSII (is there a type of patient who does particularly well or poorly on CSII?) and how CSII affects psychological factors like mood, behaviour and quality of life. Quality of

  16. DIFFUSION PUMP

    Science.gov (United States)

    Levenson, L.

    1963-09-01

    A high-vacuum diffusion pump is described, featuring a novel housing geometry for enhancing pumping speed. An upright, cylindrical lower housing portion is surmounted by a concentric, upright, cylindrical upper housing portion of substantially larger diameter; an uppermost nozzle, disposed concentrically within the upper portion, is adapted to eject downwardly a conical sheet of liquid outwardly to impinge upon the uppermost extremity of the interior wall of the lower portion. Preferably this nozzle is mounted upon a pedestal rising coaxially from within the lower portion and projecting up into said upper portion. (AEC)

  17. Cardiac conduction system

    Science.gov (United States)

    The cardiac conduction system is a group of specialized cardiac muscle cells in the walls of the heart that send signals ... to contract. The main components of the cardiac conduction system are the SA node, AV node, bundle ...

  18. Model experiments on the hydrostatic bearing of the 80 HGXW pump

    International Nuclear Information System (INIS)

    A stand simulating the design conditions in an actual sodium pump was built for testing a centrifugal liquid sodium pump with a radial hydrostatic guide bearing. The load capacity was measured on the stand and the experimental values obtained were compared to theoretical calculations. Inertia current effects included in the calculation are small and do not exceed the measurement error. (H.S.)

  19. Whole blood pumping with a microthrottle pump

    OpenAIRE

    Davies, M J; Johnston, I. D.; Tan, C. K. L.; Tracey, M. C.

    2010-01-01

    We have previously reported that microthrottle pumps (MTPs) display the capacity to pump solid phase suspensions such as polystyrene beads which prove challenging to most microfluidic pumps. In this paper we report employing a linear microthrottle pump (LMTP) to pump whole, undiluted, anticoagulated, human venous blood at 200 μl min−1 with minimal erythrocyte lysis and no observed pump blockage. LMTPs are particularly well suited to particle suspension transport by virtue of their relatively ...

  20. Using a Breast Pump

    Science.gov (United States)

    ... you can relax and not be disturbed while pumping. If you have an electric pump, find an ... otherwise irritating your nipple or breast tissue. Begin Pumping If your pump is electric or battery-powered, ...

  1. Regulation of the Na(+)-K+ pump activity and estimation of the reserve capacity in intact rat peritoneal mast cells

    DEFF Research Database (Denmark)

    Knudsen, Torben; Johansen, Torben

    1990-01-01

    Evidence is provided that regulation of the Na(+)-K+ pump activity in rat peritoneal mast cells occurs mainly through stimulation of the pump from inside the plasma membrane by sodium. It is demonstrated that there is a large reserve capacity for the exchange of intracellular sodium with extracel......Evidence is provided that regulation of the Na(+)-K+ pump activity in rat peritoneal mast cells occurs mainly through stimulation of the pump from inside the plasma membrane by sodium. It is demonstrated that there is a large reserve capacity for the exchange of intracellular sodium with...

  2. Cardiac Hypertrophy: A Review on Pathogenesis and Treatment

    Directory of Open Access Journals (Sweden)

    Ankur Rohilla

    2012-07-01

    Full Text Available Cardiac hypertrophy has been considered as an important risk factor for cardiac morbidity and mortality whose prevalence has increased during the last few decades. Cardiac hypertrophy, a disease associated with the myocardium, is characterized by thickening of ventricle wall of heart and consequent reduction in the contracting ability of heart to pump the blood. Cardiac hypertrophy has been divided into two types, i.e. physiological and pathological hypertrophy. The exercise-induced increase in the ability of pumping blood leads to thickening of ventricle wall, referred to as physiological hypertrophy. On the other hand, reduced ability of pumping blood as a result of hypertension and volume overload on heart denotes pathological hypertrophy. Numerous mediators have been found to be involved in the pathogenesis of cardiac hypertrophy that include mitogen-activated protein kinase (MAPK, protein kinase C (PKC insulin-like growth factor-I (IGF-I, phosphatidylinositol 3-kinase (PI3K-AKT/PKB, calcinurin-nuclear factor of activated T cells (NFAT and mammalian target of rapamycin (mTOR. The prevention strategy for cardiac hypertrophy involve thiazide diuretics, angiotensin-converting enzyme (ACE inhibitors, angiotensin (Ang II receptor blockers, beta blockers and calcium channel blockers. The present review article highlights the signaling mechanisms involved and the approaches required in the treatment of cardiac hypertrophy.

  3. Electromagnetic pumping of liquid lithium in inertial confinement fusion reactors

    International Nuclear Information System (INIS)

    The basic operating principles and geometries of ten electromagnetic pumps are described. Two candidate pumps, the annular-linear-induction pump and the helical-rotor electromagnetic pump, are compared for possible use in a full-scale liquid-lithium inertial confinement fusion reactor. A parametric design study completed for the helical-rotor pump is shown to be valid when applied to an experimental sodium pump. Based upon the preliminary HYLIFE requirements for a lithium flow rate per pump of 8.08 m3/s at a head of 82.5 kPa, a complete set of 70 variables are specified for a helical-rotor pump with either a normally conducting or a superconducting winding. The two alternative designs are expected to perform with efficiencies of 50 and 60%, respectively

  4. Development of sodium facilities for NSRR fast breeder reactor fuel tests. 2. Sodium capsule

    International Nuclear Information System (INIS)

    In order to commercialize fast reactors, which are expected to be long-term transmutes of plutonium and long half life radioactive wastes (such as americium) from light water reactors, safety research under accident conditions and establishment of the safety guidelines are essential. Sodium facilities, such as, (1) Purification/charging loop and test loop, and (2) Proto-type Sodium capsule, were developed and fabricated in order to pulse irradiate fast breeder reactor fuels in the Nuclear Safety Research Reactor (NSRR) of JAERI for investigation on fuel behavior under transient over-power conditions. This report presents the purpose, outlines, specifications, capabilities and operation results of the proto-type sodium capsule. Two kinds of capsule, i.e., the stagnant sodium capsule and the sodium loop, were designed to pulse irradiate Fast Reactor (FR) fuels in the NSRR under sodium cooling conditions with and without flow, respectively. Because the capsules have to safely contain chemically active sodium at high temperature and stand the pressure pulses by the sodium hummer which might be generated at fuel failure, the development of the capsule is essential for realizing the research. Thus, proto-type sodium loop, which consisted of doubly sealed container, sodium pump and flow meter, was developed. In addition, two type of flange structure for the stagnant capsule and loop was leak tested at high pressures, in order to confirm its sealing capability at room and high temperature conditions. (author)

  5. Annual report 1974. Sodium technology development programme

    International Nuclear Information System (INIS)

    The sodium technology development program comprises a number of separate research programs in the field of designing and testing parts and components for the SNR-300 reactor. Design studies and theoretical studies on cold trapping and the behavior of hydrogen in sodium circuits are reported. A preliminary test program for fighting sodium fires is completed. Results of research done on vibration measurements and counter-current mixing in a dummy tube bundle of a S.N.R. spiralized steam generator with counter-current flow are reported briefly. Research done in the field of heat transfer, pressure drop and bubble dynamics of a straight pipe steam generator are also briefly reported. To determine the influence of spiral diameter of the spiralized pipe on heat transfer in a spiralized pipe heat exchanger, a second testsection will be built in 1975. Research was reported on pump viscoseals, bearing stability, rotordynamics and bearing materials for sodium pumps. Research done on the properties of SNR-construction materials at high temperature and long time exposure and corrosion in sodium are reported. Fundamental research on corrosion accompanied this research. The report closes with results of weldability, mechanized-welding and remote welding of sodium-wetted surfaces

  6. Examination and replacement of electromagnetic pumps from FFTF primary circuits

    International Nuclear Information System (INIS)

    On November 16, 1984, a leak was discovered in the Fast Flux Test Facility (FFTF) primary sodium sampling system. The leak occurred in one of two parallel electromagnetic (EM) pumps designed to take suction from the primary system drain tank and pump sodium through the cold trap to maintain coolant purity. The purpose of this paper is to describe the examination of the pump after its removal from the circuit, define the apparent cause of the leak, and give the applications of the examination to future plant operations

  7. Characteristic analysis of a double stator annular linear electromagnetic pump

    International Nuclear Information System (INIS)

    A annular linear induction electromagnetic pump (ALIP) is generally used to transport liquid sodium coolants for liquid metal reactors. In the present study, the theoretical induction of a developing equation has been carried out for a double stator version of the ALIP which is noticebly employed for the sodium circulation of a large flowrate. The computerzed P-Q relation, which is represented by the pump geometrical and electrical variables, has been applied to a double stator version of the ALMR EM pump. An induced equation was verified by the compared analysis with the known data on the P-Q characteristic according to the input currents

  8. Platelets and cardiac arrhythmia

    Directory of Open Access Journals (Sweden)

    JonasSDe Jong

    2010-12-01

    Full Text Available Sudden cardiac death remains one of the most prevalent modes of death in industrialized countries, and myocardial ischemia due to thrombotic coronary occlusion is its primary cause. The role of platelets in the occurrence of SCD extends beyond coronary flow impairment by clot formation. Here we review the substances released by platelets during clot formation and their arrhythmic properties. Platelet products are released from three types of platelet granules: dense core granules, alpha-granules, and platelet lysosomes. The physiologic properties of dense granule products are of special interest as a potential source of arrhythmic substances. They are released readily upon activation and contain high concentrations of serotonin, histamine, purines, pyrimidines, and ions such as calcium and magnesium. Potential arrhythmic mechanisms of these substances, e.g. serotonin and high energy phosphates, include induction of coronary constriction, calcium overloading, and induction of delayed after-depolarizations. Alpha-granules produce thromboxanes and other arachidonic acid products with many potential arrhythmic effects mediated by interference with cardiac sodium, calcium and potassium channels. Alpha-granules also contain hundreds of proteins that could potentially serve as ligands to receptors on cardiomyocytes. Lysosomal products probably do not have an important arrhythmic effect. Platelet products and ischemia can induce coronary permeability, thereby enhancing interaction with surrounding cardiomyocytes. Antiplatelet therapy is known to improve survival after myocardial infarction. Although an important part of this effect results from prevention of coronary clot formation, there is evidence to suggest that antiplatelet therapy also induces anti-arrhythmic effects during ischemia by preventing the release of platelet activation products.

  9. Continuous analyzers of hydrogen and carbon in liquid sodium and of hydrocarbon total in protective atmosphere above sodium

    International Nuclear Information System (INIS)

    The principle is described of a leak detector for detecting water penetration into sodium in a steam generator. The device operates as a diffusion H-meter with an ion pump. Ni or Fe diffusion diaphragm is washed with sodium while diffused hydrogen is pumped and also monitored with the ion pump. Another detector uses the principle of analyzing hydrocarbons in the cover gas above the sodium level. The carrier gas flow for the analyzer divided into measuring and reference parts is passed through a chamber housing the diffusion standard. For measuring carbon content in sodium, the detector analytical part may be completed with a chamber with moisturizing filling for scrubbing gas. Carbon passing through the diffusion Fe diaphragm is scrubbed on the inner wall in the form of CO which is reduced to methane and measured using the detector C-meter. (M.S.)

  10. Cardiac MRI in Athletes

    NARCIS (Netherlands)

    Luijkx, T.

    2012-01-01

    Cardiac magnetic resonance imaging (CMR) is often used in athletes to image cardiac anatomy and function and is increasingly requested in the context of screening for pathology that can cause sudden cardiac death (SCD). In this thesis, patterns of cardiac adaptation to sports are investigated with C

  11. Low sodium level

    Science.gov (United States)

    Low sodium level is a condition in which the amount of sodium (salt) in the blood is lower than normal. ... Sodium is found mostly in the body fluids outside the cells. It is very important for maintaining ...

  12. Sodium and Food Sources

    Science.gov (United States)

    ... Disease Cholesterol High Blood Pressure Million Hearts® WISEWOMAN Sodium and Food Sources Recommend on Facebook Tweet Share ... food [PDF-867K] and how to reduce sodium. Sodium Reduction Is Challenging Types of food matter: More ...

  13. Gastrointestinal complications and cardiac surgery.

    Science.gov (United States)

    Allen, Sara J

    2014-06-01

    Gastrointestinal (GI) complications are an uncommon but potentially devastating complication of cardiac surgery. The reported incidence varies between .3% and 5.5% with an associated mortality of .3-87%. A wide range of GI complications are reported with bleeding, mesenteric ischemia, pancreatitis, cholecystitis, and ileus the most common. Ischemia is thought to be the main cause of GI complications with hypoperfusion during cardiac surgery as well as systemic inflammation, hypothermia, drug therapy, and mechanical factors contributing. Several nonischemic mechanisms may contribute to GI complications, including bacterial translocation, adverse drug reactions, and iatrogenic organ injury. Risk factors for GI complications are advanced age (>70 years), reoperation or emergency surgery, comorbidities (renal disease, respiratory disease, peripheral vascular disease, diabetes mellitus, cardiac failure), perioperative use of an intra-aortic balloon pump or inotrope therapy, prolonged surgery or cardiopulmonary bypass, and postoperative complications. Multiple strategies to reduce the incidence of GI complications exist, including risk stratification scores, targeted inotrope and fluid therapy, drug therapies, and modification of cardiopulmonary bypass. Currently, no single therapy has consistently proven efficacy in reducing GI complications. Timely diagnosis and treatment, while tailored to the specific complication and patient, is essential for optimal management and outcomes in this challenging patient population. PMID:25208431

  14. Flow Characteristics of the PHTS Mechanical Pump in PGSFR

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jung; Lee, Tae-Hoo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Park, Hwi-Seob [CD-adapco, Seoul (Korea, Republic of)

    2014-10-15

    The PHTS (Primary Heat Transfer System) mechanical pump is one of the most important parts in the PGSFR. The objective of the PHTS pump is to circulate a sodium coolant to transfer the heat generated in the core to the IHTS (Intermediate Heat Transfer System). Therefore, it is important to verify the performance of the PHTS pump under various flow conditions. The flow inside the pump is a very complex multi-dimensional phenomenon that depends on the rotation speed of the pump, and the geometry of the impeller and diffuser. In particular, the pump performance and flow characteristics can be evaluated using a homologous curve represented by normalized variables of the head and torque. Using a homologous curve obtained by a real pump or model pump reduced by the same specific speed is reasonable, but the detailed design procedure about the prototype PHTS pump has not been completed at this point. In this study, the flow characteristics and homologous curve of the PHTS pump are evaluated by CFD. The flow characteristic of the PHTS pump is evaluated by the CFD. The head and torque are calculated at several flow rates and rotation speeds, and these values are substituted with normalized pump parameters. Also, the homologous head and torque curve is plotted using normalized pump parameters. This curve is used as the input of the safety analysis.

  15. Pump characteristics and applications

    CERN Document Server

    Volk, Michael

    2013-01-01

    Providing a wealth of information on pumps and pump systems, Pump Characteristics and Applications, Third Edition details how pump equipment is selected, sized, operated, maintained, and repaired. The book identifies the key components of pumps and pump accessories, introduces the basics of pump and system hydraulics as well as more advanced hydraulic topics, and details various pump types, as well as special materials on seals, motors, variable frequency drives, and other pump-related subjects. It uses example problems throughout the text, reinforcing the practical application of the formulae

  16. Using a Combined Platform of Swarm Intelligence Algorithms and GIS to Provide Land Suitability Maps for Locating Cardiac Rehabilitation Defibrillators

    OpenAIRE

    KAFFASH-CHARANDABI, Neda; SADEGHI-NIARAKI, Abolghasem; Park, Dong-Kyun

    2015-01-01

    Background: Cardiac arrest is a condition in which the heart is completely stopped and is not pumping any blood. Although most cardiac arrest cases are reported from homes or hospitals, about 20% occur in public areas. Therefore, these areas need to be investigated in terms of cardiac arrest incidence so that places of high incidence can be identi-fied and cardiac rehabilitation defibrillators installed there.Methods: In order to investigate a study area in Petersburg, Pennsylvania State, and...

  17. Activity identification of peptide containing rat sodium pump α2 subunit M1-M2 extramembrane fragment in vitro%大鼠钠泵α2亚单位M1~M2膜外区多肽体外活性鉴定

    Institute of Scientific and Technical Information of China (English)

    张明娟; 杨军; 强磊; 王蓉; 宋亚燔; 牛小麟

    2008-01-01

    本文旨在研究含大鼠钠泵α2亚单位M1~M2膜外区的多肽片段(peptide contmning rat sodium pump α2 subunit M1-M21extramembrane fragment,RES2衍生物)是否具有与内源性钠泵抑制因子结合以及改善钠泵α亚单位活性的作用.采用Fmoc固相合成法合成多肽(Leu-Ala-Ala-Met-Glu-Asp-Glu-Pro-Ser-Asn-Asp-Asn-Gly-Gly-Gly-Ser),产物经高效液相色谱技术纯化,并进行质谱分析.采用放射性配体.受体结合法检测其与哇巴因的结合能力,进而采用人红细胞86Rb摄取实验检测其生物学活性.结果显示,RES2衍生物与3H-哇巴因具有一定的结合能力,其平衡解离常数(Kd)为38.46 nmol/L,IC50为6.353nmol/L.RES2衍生物可以阻断哇巴因对红细胞膜Na+,K+-ATPase的抑制作用,使红细胞86Rb摄取率从38.53%上升到83.69%左右,并呈一定的剂量依赖关系.因此,RES2衍生物不仅具有体外结合活性,而且具有改善钠泵活性的生物学效应,为其成为有效的抗高血压药物提供科学依据.%In order to explore the activity of a peptide containing rat sodium pump α2 subunit M I-M2 extramembrane fragment (RES2derivative) in vitro, the peptide (Len-Ala-Ala-Met-Glu-Asp-Glu-Pro-Ser-Asn-Asp-Asn-Gly-Gly-Gly-Ser) was synthesized by pep-tide synthesizer with Fmoc method and purified by high performance liquid chromatography (HPLC). Its binding activity wasidentified by radioligand-receptor binding assay (RRA) and its bioactivity was measured by erythrocyte 86Rb uptake. The results ofsaturation binding experiment and competitive binding experiment showed that the synthesized RES2 derivative had the capability tobind to 3H-ouabain. The dissociation constant (Kd) was 38.46 nmol/L and IC50 was 6.353 nmol/L. Erythrocyte 86Rb uptake experimentshowed that the RES2 derivative blocked the inhibitory effect of ouabain on the sodium pump on erythrocyte membrane in a dose-dependent manner. The results showed that the RES2 derivative is capable of binding to ouabain and

  18. Intraaortic Balloon Pump Counterpulsation and Cerebral Autoregulation: an observational study

    OpenAIRE

    Boots Rob; Barnett Adrian G; Timms Daniel; Dunster Kimble; Geng Shureng; Bellapart Judith; Fraser John F

    2010-01-01

    Abstract Background The use of Intra-aortic counterpulsation is a well established supportive therapy for patients in cardiac failure or after cardiac surgery. Blood pressure variations induced by counterpulsation are transmitted to the cerebral arteries, challenging cerebral autoregulatory mechanisms in order to maintain a stable cerebral blood flow. This study aims to assess the effects on cerebral autoregulation and variability of cerebral blood flow due to intra-aortic balloon pump and in...

  19. Sodium MRI in human heart: a review.

    Science.gov (United States)

    Bottomley, Paul A

    2016-02-01

    This paper offers a critical review of the properties, methods and potential clinical application of sodium ((23)Na) MRI in human heart. Because the tissue sodium concentration (TSC) in heart is about ~40 µmol/g wet weight, and the (23)Na gyromagnetic ratio and sensitivity are respectively about one-quarter and one-11th of that of hydrogen ((1)H), the signal-to-noise ratio of (23)Na MRI in the heart is about one-6000th of that of conventional cardiac (1)H MRI. In addition, as a quadrupolar nucleus, (23)Na exhibits ultra-short and multi-component relaxation behavior (T1 ~ 30 ms; T2 ~ 0.5-4 ms and 12-20 ms), which requires fast, specialized, ultra-short echo-time MRI sequences, especially for quantifying TSC. Cardiac (23)Na MRI studies from 1.5 to 7 T measure a volume-weighted sum of intra- and extra-cellular components present at cytosolic concentrations of 10-15 mM and 135-150 mM in healthy tissue, respectively, at a spatial resolution of about 0.1-1 ml in 10 min or so. Currently, intra- and extra-cellular sodium cannot be unambiguously resolved without the use of potentially toxic shift reagents. Nevertheless, increases in TSC attributable to an influx of intra-cellular sodium and/or increased extra-cellular volume have been demonstrated in human myocardial infarction consistent with prior animal studies, and arguably might also be seen in future studies of ischemia and cardiomyopathies--especially those involving defects in sodium transport. While technical implementation remains a hurdle, a central question for clinical use is whether cardiac (23)Na MRI can deliver useful information unobtainable by other more convenient methods, including (1)H MRI. PMID:25683054

  20. Cardiac perception and cardiac control. A review.

    Science.gov (United States)

    Carroll, D

    1977-12-01

    The evidence regarding specific cardiac perception and discrimination, and its relationship to voluntary cardiac control, is critically reviewed. Studies are considered in three sections, depending on the method used to assess cardiac perception: questionnaire assessment, discrimination procedures, and heartbeat tracking. The heartbeat tracking procedure would appear to suffer least from interpretative difficulties. Recommendations are made regarding the style of analysis used to assess heartbeat perception in such tracking tasks. PMID:348240

  1. Minimum-test series for the intermediate-size inducer pump in SPTF at ETEC

    International Nuclear Information System (INIS)

    The overall test program includes pump assembly, installation, testing, removal from the test loop, disassembly and final inspection of the entire pump. Testing will include: checkout tests, head/flow and efficiency characterizations at design and two-loop flow/speed ratios and at selected sodium temperatures; suction performance determination; and a design point endurance test, up to 2000 hours, based on available time. The endurance test will be run at 100 percent NPSH margin. After testing, the pump will be cleaned of sodium, disassembled, and examined to determine the effects of operation at 100 percent NPSH margin for an extended period of time. The testing will be done at Energy Technology Engineering Center (ETEC). Assembly, sodium removal, disassembly, and initial inspection will be performed at Component Handling and Cleaning Facility (CHCF) and sodium testing will be done at Sodium Pump Test Facility

  2. Off-pump CABG surgery reduces systemic inflammation compared with on-pump surgery but does not change systemic endothelial responses : a prospective randomized study

    NARCIS (Netherlands)

    Jongman, Rianne M.; Zijlstra, Jan G.; Kok, Wendelinde F.; van Harten, Annemarie E.; Mariani, Massimo A.; Moser, Jill; Struys, Michel M. R. F.; Absalom, Anthony R.; Molema, Grietje; Scheeren, Thomas W. L.; van Meurs, Matijs

    2014-01-01

    Coronary artery bypass graft (CABG) surgery can result in severe postoperative organ failure. During CABG surgery, cardiopulmonary bypass (CPB) with cardiac arrest is often used (on-pump CABG), which often results in a systemic inflammatory response. To reduce this inflammatory response, off-pump CA

  3. Diclofenac sodium.

    Science.gov (United States)

    Small, R E

    1989-08-01

    The pharmacology, pharmacokinetics, clinical efficacy, adverse effects, and dosage of diclofenac sodium are reviewed. Diclofenac, the first nonsteroidal anti-inflammatory agent (NSAID) to be approved that is a phenylacetic acid derivative, competes with arachidonic acid for binding to cyclo-oxygenase, resulting in decreased formation of prostaglandins. The drug has both analgesic and antipyretic activities. Diclofenac is efficiently absorbed from the gastrointestinal tract; peak plasma concentrations occur 1.5 to 2.0 hours after ingestion in fasting subjects. Even though diclofenac has a relatively short elimination half-life in plasma (1.5 hours), it persists in synovial fluid. The drug is metabolized in the liver and is eliminated by urinary and biliary excretion. In clinical trials, diclofenac was as effective as aspirin, diflunisal, indomethacin, sulindac, ibuprofen, ketoprofen, and naproxen in improving function and reducing pain in patients with rheumatoid arthritis. For treatment of osteoarthritis, diclofenac was equivalent in efficacy to aspirin, diflunisal, indomethacin, sulindac, ibuprofen, ketoprofen, naproxen, flurbiprofen, mefenamic acid, and piroxicam. Diclofenac was as effective as indomethacin or sulindac in treating ankylosing spondylitis. The most frequent adverse effects reported for diclofenac were gastrointestinal, but these effects were fewer and less serious than occurred with aspirin or indomethacin; in addition, diclofenac caused fewer central nervous system reactions than indomethacin. Diclofenac is administered in divided doses with meals. The recommended total daily dosage is 100 to 150 mg (osteoarthritis and ankylosing spondylitis) or 150 to 200 mg (rheumatoid arthritis). Diclofenac is effective, but no more so than other NSAIDs. It is structurally distinct and offers another choice in the treatment of rheumatological conditions. PMID:2670397

  4. Liquid sodium pool fires

    International Nuclear Information System (INIS)

    Experimental sodium pool combustion results have led to a definition of the combustion kinetics, and have revealed the hazards of sodium-concrete contact reactions and the possible ignition of organic matter (paint) by hydration of sodium peroxide aerosols. Analysis of these test results shows that the controlling mechanism is sodium evaporation diffusion. (author)

  5. Heat pump technology

    CERN Document Server

    Von Cube, Hans Ludwig; Goodall, E G A

    2013-01-01

    Heat Pump Technology discusses the history, underlying concepts, usage, and advancements in the use of heat pumps. The book covers topics such as the applications and types of heat pumps; thermodynamic principles involved in heat pumps such as internal energy, enthalpy, and exergy; and natural heat sources and energy storage. Also discussed are topics such as the importance of the heat pump in the energy industry; heat pump designs and systems; the development of heat pumps over time; and examples of practical everyday uses of heat pumps. The text is recommended for those who would like to kno

  6. Sodium removal from sodium wetted under sodium ultra sonic scanner

    International Nuclear Information System (INIS)

    Highlights: ► Sodium wetted USUSS was subjected to sodium cleaning by water vapour–CO2 process. ► Hydrogen released during the process was monitored and regulated in safe limit. ► The temperature of USUSS was maintained below 80 °C to prevent caustic corrosion. ► The experiment revealed intricacies involved in the cleaning operation. ► The operational parameters for safe cleaning were optimised. - Abstract: Sodium is used as a coolant in primary and secondary heat transport systems of Liquid Metal cooled Fast Breeder Reactors (LMFBR). The Prototype Fast Breeder Reactor (PFBR) is in advanced stage of construction at Kalpakkam, India. Under Sodium Ultra Sonic Scanner (USUSS) is used to image the components dipped in sodium and more specifically the gap between Sub Assembly (SA) heads and the control plug. This is essential to confirm that no SA is protruding from its position. USUSS has to be qualified in sodium before its use in the reactor. After sodium testing, sodium adhering to the USUSS needs to be removed to prevent reaction with oxygen and moisture present in air when it is taken out. The sodium removal process is based on the use of moist carbon-di-oxide (CO2) at a temperature of about 353 K. The reaction rate is controlled by varying the ratio of CO2 to moisture. Hydrogen released during the reaction of sodium with moisture is continuously monitored to ensure safe limits of hydrogen concentration. This paper describes the details of the experimental setup used in a cleaning pit for the removal of sodium adhering on USUSS and the technical details of the cleaning process.

  7. What Is Cardiac Rehabilitation?

    Science.gov (United States)

    ANSWERS by heart Treatments + Tests What Is Cardiac Rehabilitation? A cardiac rehabilitation (rehab) program takes place in a hospital or ... special help in making lifestyle changes. During your rehabilitation program you’ll… • Have a medical evaluation to ...

  8. A current-driven nanometer water pump.

    Science.gov (United States)

    Su, Jiaye; Yang, Keda

    2016-03-01

    The design of a water pump, which has huge potential for applications in nanotechnology and daily life, is the dream of many scientists. In this paper, we successfully design a nanometer water pump by using molecular dynamics simulations. Ions of either sodium or chlorine in a narrow channel will generate electric current under electric fields, which then drives the water through a wider channel, similar to recent experimental setups. Considerable water flux is achieved within small field strengths that are accessible by experimentation. Of particular interest, is that for sodium the water flux increases almost linearly with field strengths; while for chlorine there exists a critical field strength, the water flux exhibits a plateau before the critical value and increases linearly after it. This result follows the behavior of ion velocity, which is related to friction behavior. We also estimate the power and energy consumption for such a pump, and compare it to the macroscopic mechanical pumps. A further comparison suggests that different ions will have different pumping abilities. This study not only provides new, significant results with possible connection to existing research, but has tremendous potential application in the design of nanofluidic devices. PMID:26822782

  9. A current-driven nanometer water pump

    Science.gov (United States)

    Su, Jiaye; Yang, Keda

    2016-03-01

    The design of a water pump, which has huge potential for applications in nanotechnology and daily life, is the dream of many scientists. In this paper, we successfully design a nanometer water pump by using molecular dynamics simulations. Ions of either sodium or chlorine in a narrow channel will generate electric current under electric fields, which then drives the water through a wider channel, similar to recent experimental setups. Considerable water flux is achieved within small field strengths that are accessible by experimentation. Of particular interest, is that for sodium the water flux increases almost linearly with field strengths; while for chlorine there exists a critical field strength, the water flux exhibits a plateau before the critical value and increases linearly after it. This result follows the behavior of ion velocity, which is related to friction behavior. We also estimate the power and energy consumption for such a pump, and compare it to the macroscopic mechanical pumps. A further comparison suggests that different ions will have different pumping abilities. This study not only provides new, significant results with possible connection to existing research, but has tremendous potential application in the design of nanofluidic devices.

  10. Corrosion and mass transport in liquid sodium

    International Nuclear Information System (INIS)

    Tests on carbon and low alloy ferritic steels in thermal convection and pumped sodium loops have provided data on general corrosion and carbon transfer behaviour of the materials tested. It was found that carbon steel decarburised according to theoretical predictions and that 1Cr1/2Mo and 2 1/4Cr1Mo steels decarburised to a lesser exten if unstabilised. Additions of niobium were ineffective in preventing decarburisation but under the same conditions titanium added either alone or with niobium caused the same steels to become carburised. Corrosion rates for 9Cr1Mo and TP316 steels in niobium caused the same steels to become carburised. Corrosion rates for 9Cr1Mo and TP316 steels in pumped sodium were found to be of the same order but significantly lower than published elsewhere. (author)

  11. Diffuse infiltrative cardiac tuberculosis

    International Nuclear Information System (INIS)

    We present the cardiac magnetic resonance images of an unusual form of cardiac tuberculosis. Nodular masses in a sheet-like distribution were seen to infiltrate the outer myocardium and pericardium along most of the cardiac chambers. The lesions showed significant resolution on antitubercular therapy

  12. Hemodynamic and neuroendocrine responses to changes in sodium intake in compensated heart failure

    DEFF Research Database (Denmark)

    Damgaard, Morten; Norsk, Peter; Gustafsson, Finn;

    2005-01-01

    Patients with untreated heart failure (HF) exhibit a blunted hemodynamic and neuroendocrine response to a high sodium intake, leading to excessive sodium and water retention. However, it is not known whether this is the case for patients with compensated HF receiving angiotensin-converting enzyme...... unchanged. In conclusion, high sodium intake was tolerated without any excessive sodium and water retention in medically treated patients with compensated HF. The observation that high sodium intake improves cardiac performance, induces peripheral vasodilatation, and suppresses the release of......-state conditions, hemodynamic and neuroendocrine examinations were performed at rest and during bicycle exercise. In seated HF patients, high sodium intake increased body weight (1.6 +/- 0.4%), plasma volume (9 +/- 2%), cardiac index (14 +/- 6%), and stroke volume index (21 +/- 5%), whereas mean arterial pressure...

  13. Multiple pump housing

    Science.gov (United States)

    Donoho, II, Michael R.; Elliott; Christopher M.

    2010-03-23

    A fluid delivery system includes a first pump having a first drive assembly, a second pump having a second drive assembly, and a pump housing. At least a portion of each of the first and second pumps are located in the housing.

  14. Types of Breast Pumps

    Science.gov (United States)

    ... breast-shield. Some experts discourage the use of bicycle horn pumps because they may be difficult to clean and dry. Battery-Powered and Electric Pumps A powered breast pump uses batteries or a cord plugged into an electrical outlet to power a small motorized pump that ...

  15. Short review of sodium removal experience in PNC

    International Nuclear Information System (INIS)

    Experiences in the removal of sodium from fuel assemblies and other reactor components are shortly reviewed. The experiences were obtained from the operation of the FBR ''JOYO'' and at the research work facilities in the O-arai Engineering Center, PNC. As for JOYO, many dummy fuel and blanket fuel sub-assemblies and dummy control rods have been sent to the Fuel Cleaning Facility for sodium removal. Steam and demineralized water have been used for the process. Sodium removal from the grapples of the fuel handling machines was done after a certain time of service in sodium. For this process, alcohol has been used. Sodium removal from the mechanical sodium pump of the primary coolant system was done with steam-nitrogen and water. At the research work facilities, on the other hand, sodium removal tests were performed for various components, such as the secondary mockup pump of JOYO, 1 MW steam generator, sector model of the intermediate heat exchanger of JOYO, and mockup isolation valves. From these experiences, it was found that sodium removal from small crevices by conventional methods was difficult. In order to improve this situation, saturation boiling process was designed, and the experiment using test pieces has been initiated. This process is modification of the water charging process, in which water is charged into the process cell or tank and the inside pressure is adjusted so that boiling of the water is initiated and the formation of hydroxide film is prevented. (Aoki, K.)

  16. The role of cell savers and filters in cardiac surgery

    NARCIS (Netherlands)

    Vermeijden, Jan Wytze

    2015-01-01

    This thesis investigates the different possibilities of blood sparing strategies in routine cardiac on pump surgery. Reducing allogeneic blood transfusions can improve patient outcome. The main focus of the thesis is on methods of improving shed and cardiotomy blood by filtration with the use of leu

  17. Status of integrated IHX/Pump development for JSFR

    International Nuclear Information System (INIS)

    This paper illuminates the status of research and development on the integrated IHX/Pump concept. The integrated IHX/Pump is the incorporated component of the intermediate heat exchanger (IHX) and the primary pump. Among the innovative technologies of the Japan Sodium-Cooled Fast Reactor (JSFR) in the Fast Reactor Cycle Technology Development (FaCT) project, the integrated IHX/Pump concept is one of the major innovative ideas for plant economy by reducing the amount of material in the primary cooling system and the building volume. This report summarizes the view of the integrated IHX/Pump, a development plan, evaluation methods, and the present test results with the 1/4-scale IHX/Pump test device. (author)

  18. Reversible effects of acute hypertension on proximal tubule sodium transporters

    DEFF Research Database (Denmark)

    Zhang, Y; Magyar, C E; Norian, J M;

    1998-01-01

    blood pressure (BP) of 50 mmHg for 5 min, 2) restoration of normotension after the first protocol, or 3) sham operation. Systolic hypertension increased urine output and endogenous lithium clearance three- to fivefold within 5 min, but these returned to basal levels only 15 min after BP was restored...... BP may be mediated by rapid reversible regulation of sodium pump activity and relocation of apical sodium transporters....

  19. Potential and limits of sodium hydroxide as an additive to the binary system ammonia/water in absorption heat pumps; Potenzial und Grenzen von Natriumhydroxid als Zusatz zum Stoffpaar Ammoniak/Wasser in Absorptions-Waermepumpen

    Energy Technology Data Exchange (ETDEWEB)

    Kotenko, Oleksandr; Moser, Harald; Fenzl, Thomas; Rieberer, Rene [Technische Univ. Graz (Austria). Inst. fuer Waermetechnik

    2011-07-01

    Several authors proposed the use of sodium hydroxide (NaOH) as an additive to the ammonia/water working fluid mixture (NH{sub 3} / H{sub 2}O), especially in solar air conditioners. Measured vapour-liquid equilibrium data of this tertiary mixture are found in the relevant literature. Thermodynamic calculations carried out with these data show that the efficiency (COP) will be enhanced in theory while the rectification time will decrease. To verify these theoretical considerations and to gain practical experience with the tertiary mixture NH{sub 3} / H{sub 2}O / NaOH, a test stand was constructed at the Institut fuer Waermetechnik, and measurements were carried out on the mixture NH{sub 3} / H{sub 2}O, i.e. without NaOH, and with 5% NaOH. The technical feasibility of the process was established, although NaOH depositions in the refrigerating circuit caused operational disturbances, so that the mixture had to be renewed regularly and the plant had to be flushed with water. The expected efficiency improvement was not observed. Analyses using ''ASPEN Plus'' showed that this was the result of lower absorber efficiency, which may be due to the higher circulation rate and higher viscosity of the working fluid mixture. Measurements showed a moderate improvements of heat transfer in the expeller after addition of NaOH; no effects were found in the evaporator, solvent heat exchanger and rectification column. The findings suggest that fast implementation of NH{sub 3} / H{sub 2}O / NaOH-AWP is not realistic. Considerable research and development will still be required for optimisation of the absorber for operation with NaOH. [German] Die Verwendung von Natriumhydroxid (NaOH) als Zusatz zum Arbeitsstoffgemisch Ammoniak / Wasser (NH{sub 3} / H{sub 2}O) wurde von verschiedenen Autoren insbesondere fuer das Anwendungsgebiet der solaren Klimatisierung vorgeschlagen. In der einschlaegigen Literatur wurden gemessene Dampf-Fluessig-Gleichgewichts-Daten von diesem

  20. Cardiac tumours in children

    Directory of Open Access Journals (Sweden)

    Parsons Jonathan M

    2007-03-01

    Full Text Available Abstract Cardiac tumours are benign or malignant neoplasms arising primarily in the inner lining, muscle layer, or the surrounding pericardium of the heart. They can be primary or metastatic. Primary cardiac tumours are rare in paediatric practice with a prevalence of 0.0017 to 0.28 in autopsy series. In contrast, the incidence of cardiac tumours during foetal life has been reported to be approximately 0.14%. The vast majority of primary cardiac tumours in children are benign, whilst approximately 10% are malignant. Secondary malignant tumours are 10–20 times more prevalent than primary malignant tumours. Rhabdomyoma is the most common cardiac tumour during foetal life and childhood. It accounts for more than 60% of all primary cardiac tumours. The frequency and type of cardiac tumours in adults differ from those in children with 75% being benign and 25% being malignant. Myxomas are the most common primary tumours in adults constituting 40% of benign tumours. Sarcomas make up 75% of malignant cardiac masses. Echocardiography, Computing Tomography (CT and Magnetic Resonance Imaging (MRI of the heart are the main non-invasive diagnostic tools. Cardiac catheterisation is seldom necessary. Tumour biopsy with histological assessment remains the gold standard for confirmation of the diagnosis. Surgical resection of primary cardiac tumours should be considered to relieve symptoms and mechanical obstruction to blood flow. The outcome of surgical resection in symptomatic, non-myxomatous benign cardiac tumours is favourable. Patients with primary cardiac malignancies may benefit from palliative surgery but this approach should not be recommended for patients with metastatic cardiac tumours. Surgery, chemotherapy and radiotherapy may prolong survival. The prognosis for malignant primary cardiac tumours is generally extremely poor.

  1. Pump element for a tube pump

    DEFF Research Database (Denmark)

    2011-01-01

    The invention relates to a tube pump comprising a tube and a pump element inserted in the tube, where the pump element comprises a rod element and a first and a second non-return valve member positioned a distance apart on the rod element. The valve members are oriented in the same direction...... portion acts to alternately close and open the valve members thereby generating a fluid flow through the tube. The invention further relates to a pump element comprising at least two non-return valve members connected by a rod element, and for insertion in an at least partly flexible tube in such tube...... pump as mentioned above, thereby acting to generate a fluid flow through the tube upon repeated deformation of the tube between the two valve members. The pump element may comprise a connecting part for coupling to another tube and may comprise a sealing part establishing a fluid tight connection to a...

  2. Independent system of after-heat removal in a sodium cooled fast neutron reactor

    International Nuclear Information System (INIS)

    A system of after-heat removal in sodium cooled fast reactor is described. The device, according to the main patent, is characterized in that each coolant loop includes, in parallel to the secondary sodium circuit, an auxiliary secondary circuit in which a chemically inert gas removes heat from the primary sodium; said auxiliary secondary circuit comprises at least one gas turbine fed with said inert gas and working in closed-cycle with power production. In the present variant the gas turbine also works at least one of the primary sodium pumps and, if required, at least one of the secondary sodium pumps and at least one of the main or emergency pumps feeding the steam generator

  3. Radioactive sodium processing apparatus

    International Nuclear Information System (INIS)

    Purpose: To enable safety, continuous and economical disposal for radioactive sodium while preventing radioactive contaminations. Constitution: Reaction gas introduction pipe for introducing oxygen and carbon dioxygen, and steams for accelerating the processing speed, as well as a discharge pipe for sodium carbonate as reaction products are connected to the lower side wall of a radioactive sodium processing container. A screw conveyor is mounted within the radioactive sodium processing container and a torque meter is disposed in the central axis of the conveyor. Signals from the torque meter are sent to an oxygen introduction control device. V-shaped recesses are formed to the screw blades of the conveyor for improving the separating efficiency between sodium carbonate produced through the procession and not-processed radioactive sodium. Since sodium is converted after the process into sodium carbonate, it can be handled and stored within ease. (Yoshihara, H.)

  4. Sodium Ferric Gluconate Injection

    Science.gov (United States)

    Sodium ferric gluconate injection is used to treat iron-deficiency anemia (a lower than normal number of ... are also receiving the medication epoetin (Epogen, Procrit). Sodium ferric gluconate injection is in a class of ...

  5. Docusate Sodium and Pregnancy

    Science.gov (United States)

    ... live chat Live Help Fact Sheets Share Docusate Sodium Friday, 01 April 2016 In every pregnancy, a ... This sheet talks about whether exposure to docusate sodium may increase the risk for birth defects over ...

  6. Diclofenac sodium overdose

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/002630.htm Diclofenac sodium overdose To use the sharing features on this page, please enable JavaScript. Diclofenac sodium is a prescription medicine used to relieve pain ...

  7. Sodium carbonate poisoning

    Science.gov (United States)

    Sodium carbonate (known as washing soda or soda ash) is a chemical found in many household and ... products. This article focuses on poisoning due to sodium carbonate. This article is for information only. Do ...

  8. Sodium hydroxide poisoning

    Science.gov (United States)

    Sodium hydroxide is a very strong chemical. It is also known as lye and caustic soda. This ... poisoning from touching, breathing in (inhaling), or swallowing sodium hydroxide. This article is for information only. Do ...

  9. Naproxen sodium overdose

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/002507.htm Naproxen sodium overdose To use the sharing features on this page, please enable JavaScript. Naproxen sodium is a nonsteroidal anti-inflammatory drug (NSAID) used ...

  10. Does Off-pump Coronary Artery Bypass Reduce the Prevalence of Atrial Fibrillation?

    OpenAIRE

    Khosrow Hashemzadeh; Marjan Dehdilani; Mahnaz Dehdilani

    2013-01-01

    Introduction: To examine whether or not off-pump CABG (Coronary Artery Bypass Reduce) reduces the incidence of AF after cardiac surgery. Methods: The study was carried out in 939 consecutive coronary artery disease patients with sinus rhythm from which 383 patients underwent off-pump CABG, and 556 patients were operated through on-pump CABG. All patients were monitored postoperatively during intensive care unit (ICU) stay. Then, the incidence and predictive risk factors of post operative A...

  11. Does Off-pump Coronary Artery Bypass Reduce the Prevalence ofAtrial Fibrillation?

    OpenAIRE

    Hashemzadeh, Khosrow; Dehdilani, Marjan; Dehdilani, Mahnaz

    2013-01-01

    Introduction: To examine whether or not off-pump CABG (Coronary Artery Bypass Reduce) reduces the incidence of AF after cardiac surgery. Methods: The study was carried out in 939 consecutive coronary artery disease patients with sinus rhythm from which 383 patients underwent off-pump CABG, and 556 patients were operated through on-pump CABG. All patients were monitored postoperatively during intensive care unit (ICU) stay. Then, the incidence and predictive risk factors of post opera...

  12. Stimulating endogenous cardiac regeneration

    Directory of Open Access Journals (Sweden)

    Amanda eFinan

    2015-09-01

    Full Text Available The healthy adult heart has a low turnover of cardiac myocytes. The renewal capacity, however, is augmented after cardiac injury. Participants in cardiac regeneration include cardiac myocytes themselves, cardiac progenitor cells, and peripheral stem cells, particularly from the bone marrow compartment. Cardiac progenitor cells and bone marrow stem cells are augmented after cardiac injury, migrate to the myocardium, and support regeneration. Depletion studies of these populations have demonstrated their necessary role in cardiac repair. However, the potential of these cells to completely regenerate the heart is limited. Efforts are now being focused on ways to augment these natural pathways to improve cardiac healing, primarily after ischemic injury but in other cardiac pathologies as well. Cell and gene therapy or pharmacological interventions are proposed mechanisms. Cell therapy has demonstrated modest results and has passed into clinical trials. However, the beneficial effects of cell therapy have primarily been their ability to produce paracrine effects on the cardiac tissue and recruit endogenous stem cell populations as opposed to direct cardiac regeneration. Gene therapy efforts have focused on prolonging or reactivating natural signaling pathways. Positive results have been demonstrated to activate the endogenous stem cell populations and are currently being tested in clinical trials. A potential new avenue may be to refine pharmacological treatments that are currently in place in the clinic. Evidence is mounting that drugs such as statins or beta blockers may alter endogenous stem cell activity. Understanding the effects of these drugs on stem cell repair while keeping in mind their primary function may strike a balance in myocardial healing. To maximize endogenous cardiac regeneration,a combination of these approaches couldameliorate the overall repair process to incorporate the participation ofmultiple cell players.

  13. The abdominal circulatory pump.

    Directory of Open Access Journals (Sweden)

    Andrea Aliverti

    Full Text Available Blood in the splanchnic vasculature can be transferred to the extremities. We quantified such blood shifts in normal subjects by measuring trunk volume by optoelectronic plethysmography, simultaneously with changes in body volume by whole body plethysmography during contractions of the diaphragm and abdominal muscles. Trunk volume changes with blood shifts, but body volume does not so that the blood volume shifted between trunk and extremities (Vbs is the difference between changes in trunk and body volume. This is so because both trunk and body volume change identically with breathing and gas expansion or compression. During tidal breathing Vbs was 50-75 ml with an ejection fraction of 4-6% and an output of 750-1500 ml/min. Step increases in abdominal pressure resulted in rapid emptying presumably from the liver with a time constant of 0.61+/-0.1SE sec. followed by slower flow from non-hepatic viscera. The filling time constant was 0.57+/-0.09SE sec. Splanchnic emptying shifted up to 650 ml blood. With emptying, the increased hepatic vein flow increases the blood pressure at its entry into the inferior vena cava (IVC and abolishes the pressure gradient producing flow between the femoral vein and the IVC inducing blood pooling in the legs. The findings are important for exercise because the larger the Vbs the greater the perfusion of locomotor muscles. During asystolic cardiac arrest we calculate that appropriate timing of abdominal compression could produce an output of 6 L/min. so that the abdominal circulatory pump might act as an auxiliary heart.

  14. Gastrostomy feeding tube - pump - child

    Science.gov (United States)

    Feeding - gastrostomy tube - pump; G-tube - pump; Gastrostomy button - pump; Bard Button - pump; MIC-KEY - pump ... Gather supplies: Feeding pump (electronic or battery powered) Feeding set that matches the feeding pump (includes a feeding bag, drip chamber, roller clamp, ...

  15. Sodium and potassium

    International Nuclear Information System (INIS)

    Present article is devoted to sodium and potassium content in fluoride. In order to obtain the comprehensive view on sodium and potassium distribution in fluorite 892 mono mineral samples of various geologic deposits and ores of Kazakhstan, Uzbekistan, Tajikistan were analyzed. The content of sodium and potassium in fluorite of geologic deposits of various mineralogical and genetic type was defined.

  16. SODIUM ENVIRONMENTS IN GLASS

    OpenAIRE

    Greaves, G.

    1981-01-01

    Sodium environments have been measured directly in several oxide glasses using EXAFS at the sodium K edge. The existence of local structure around sodium in glass contradicts the conventional Zachariasen model. Analysis of the EXAFS indicates there are significant differences relating to the glass modifier : glass former chemistry - the details of which demonstrate similarities with crystalline silicates and borates.

  17. Tritium gas transfer pump development

    International Nuclear Information System (INIS)

    Non-lubricated, hermetically sealed pumps for tritium service have been selected to replace Sprengel pumps in the existing Tritium Facility. These pumps will be the primary gas-transfer pumps in the planned Replacement Tritium Facility. The selected pumps are Metal Bellows Corporation's bellows pumps and Normetex scroll pumps. Pumping range for a Normetex/Metal Bellows system is from 0.01 torr suction to 2300 torr discharge. Performance characteristics of both pumps are presented. 10 figs

  18. Large electromagnetic pumps. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Kilman, G.B.

    1976-01-01

    The development of large electromagnetic pumps for the liquid metal heat transfer systems of fission reactors has progressed for a number of years. Such pumps are now planned for fusion reactors and solar plants as well. The Einstein-Szilard (annular) pump has been selected as the preferred configuration. Some of the reasons that electromagnetic pumps may be preferred over mechanical pumps and why the annular configuration was selected are discussed. A detailed electromagnetic analysis of the annular pump, based on slug flow, is presented. The analysis is then used to explore the implications of large size and power on considerations of electromagnetic skin effect, geometric skin effect and the cylindrical geometry.

  19. Preoperative cardiac risk management

    OpenAIRE

    Vidaković Radosav; Poldermans Don; Nešković Aleksandar N.

    2011-01-01

    Approximately 100 million people undergo noncardiac surgery annually worldwide. It is estimated that around 3% of patients undergoing noncardiac surgery experience a major adverse cardiac event. Although cardiac events, like myocardial infarction, are major cause of perioperative morbidity or mortality, its true incidence is difficult to assess. The risk of perioperative cardiac complications depends mainly on two conditions: 1) identified risk factors, and 2) the type of the surgical p...

  20. Short review of sodium removal experience in PNC

    International Nuclear Information System (INIS)

    Since the establishment of the Power Reactor and Nuclear Fuel Development Corporation (PNC), various research work and development have been carried out for the development of sodium cooled fast breeder reactors. Most of the works, especially those related to large scale facilities are done at the O-arai Engineering Center (OEC) of the PNC. 'Sodium Removal' from components or assemblies has been an area with much concern from the beginning of these works. Among the conventional methods, removal by steam, water, alcohol and vacuumization at high temperatures have been done. In 'Joyo', the experimental fast breeder reactor which reached initial criticality in April 1977, sodium removal from the grapples of the fuel handling facility and the fuel assemblies which come out of the reactor are done as routine work during refueling. Furthermore, when maintenance works for components, such as mechanical sodium pumps for the core cooling system, are done, sodium removal will be done in an exclusive maintenance building

  1. Insulin pump (image)

    Science.gov (United States)

    The catheter at the end of the insulin pump is inserted through a needle into the abdominal ... with diabetes. Dosage instructions are entered into the pump's small computer and the appropriate amount of insulin ...

  2. Proton pump inhibitors

    Science.gov (United States)

    Proton pump inhibitors (PPIs) are medicines that work by reducing the amount of stomach acid made by glands in ... Proton pump inhibitors are used to: Relieve symptoms of acid reflux, or gastroesophageal reflux disease (GERD). This is a ...

  3. Proton pump inhibitors

    Science.gov (United States)

    Proton pump inhibitors (PPIs) are medicines that work by reducing the amount of stomach acid made by ... Proton pump inhibitors are used to: Relieve symptoms of acid reflux, or gastroesophageal reflux disease (GERD). This ...

  4. Factors influencing the cardiac MIBG accumulation

    International Nuclear Information System (INIS)

    Following factors possibly influencing the cardiac MIBG accumulation were examined mainly in mice. 1. The specific activity of the MIBG (meta-iodo-benzyl guanidine) on the neuronal and non-neuronal fractions. 2. Motor restriction stress on MIBG accumulation and washout. 3. Loading and restriction of sodium chloride on the accumulation and effect of suppression of renin-angiotensin system. 4. Examinations in Dahl rats. 125I- or 131I-MIBG was intravenously administered to mice at 74 kBq. At 30 min or 4 hr after administration, mice were sacrificed and their left ventricles were dissected out for measurement of radioactivity in a liquid scintillation counter. Salt-sensitive and -resistant Dahl rats were given with 37 MBq of 123I-MIBG and cardiac radioactivity was measured externally for calculation of washout. Factors examined were found highly correlated with the accumulation of MIBG and measurement of its washout was considered useful for evaluating sympathetic activity. (K.H.)

  5. Importance of the Voltage Dependence of Cardiac Na/K ATPase Isozymes.

    Science.gov (United States)

    Stanley, Christopher M; Gagnon, Dominique G; Bernal, Adam; Meyer, Dylan J; Rosenthal, Joshua J; Artigas, Pablo

    2015-11-01

    Cardiac cells express more than one isoform of the Na, K-ATPase (NKA), the heteromeric enzyme that creates the Na(+) and K(+) gradients across the plasmalemma. Cardiac isozymes contain one catalytic α-subunit isoform (α1, α2, or α3) associated with an auxiliary β-subunit isoform (β1 or β2). Past studies using biochemical approaches have revealed minor kinetic differences between isozymes formed by different α-β isoform combinations; these results make it difficult to understand the physiological requirement for multiple isoforms. In intact cells, however, NKA enzymes operate in a more complex environment, which includes a substantial transmembrane potential. We evaluated the voltage dependence of human cardiac NKA isozymes expressed in Xenopus oocytes, and of native NKA isozymes in rat ventricular myocytes, using normal mammalian physiological concentrations of Na(+)o and K(+)o. We demonstrate that although α1 and α3 pumps are functional at all physiologically relevant voltages, α2β1 pumps and α2β2 pumps are inhibited by ∼75% and ∼95%, respectively, at resting membrane potentials, and only activate appreciably upon depolarization. Furthermore, phospholemman (FXYD1) inhibits pump function without significantly altering the pump's voltage dependence. Our observations provide a simple explanation for the physiological relevance of the α2 subunit (∼20% of total α subunits in rat ventricle): they act as a reserve and are recruited into action for extra pumping during the long-lasting cardiac action potential, where most of the Na(+) entry occurs. This strong voltage dependence of α2 pumps also helps explain how cardiotonic steroids, which block NKA pumps, can be a beneficial treatment for heart failure: by only inhibiting the α2 pumps, they selectively reduce NKA activity during the cardiac action potential, leading to an increase in systolic Ca(2+), due to reduced extrusion through the Na/Ca exchanger, without affecting resting Na(+) and Ca(2

  6. Photovoltaic pump systems

    Science.gov (United States)

    Klockgether, J.; Kiessling, K. P.

    1983-09-01

    Solar pump systems for the irrigation of fields and for water supply in regions with much sunshine are discussed. For surface water and sources with a hoisting depth of 12 m, a system with immersion pumps is used. For deep sources with larger hoisting depths, an underwater motor pump was developed. Both types of pump system meet the requirements of simple installation and manipulation, safe operation, maintenance free, and high efficiency reducing the number of solar cells needed.

  7. Autologous Transfusion in Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    Radmehr H

    2003-11-01

    Full Text Available Preoperative autologous blood donation is commonly used to reduce exposure to homologous blood transfusions among patients undergoing elective cardiac surgery. The aim of this study was to evaluate the effect of autologous transfusion on patients' hematocryte value, intra and postoperative blood loss, hospitalization time, the development of infective complications and other factors. Materials and Methods: Between June 2001 to April 2002, 208 patients were underwent cardiac surgery in cardiac surgery ward in Imam Khomeini Medical Center. One or more blood units donate from 104 Patients before cardiopulmonary bypass and heparin injection, and transfused to them after CPB and Protamin injection (autologous Group, group 1. 104 patients underwent cardiac surgery routinely (control group, group 2."nResults: Mean of age was 55.9±8.6 in group 1 and 56.6±9.3 in group 2 (P=NS. 73 male and 31 females were in group 1 and 79 males and 25 females were in group 2 (P=NS. Smoking, familial history, hyperlipidemia, diabetes mellitus, renal failure, hypertension, stroke, and history of myocardial infarction was similar in two groups."nSeverity of angina, urgency operation, number vessels disease, duration of cardiopulmonary bypass, duration of aortic cross clamp time, use of internal thoracic artery graft, and number of grafts was similar in both groups. Mean of bleeding post operation was 548 cc in group 1 and 803 cc in-group 2 (P=0.003. Bleeding that need to operation was 1.8% in group 1 and 8.6% in group 2 (P=0.002. Wound infection, mediastinitis, renal failure, ventilatory prolonged, stroke, need to Intra-aortic Balloon Pump (IABP, intraoperative bleeding, and hospital stay was similar in both groups. Mean of extubationt time was 10.2 hours in group 1 and 14.8 hours in group 2 (P=0.001."nConclusion: Preoperative and intra-operative donations are safe and continue to contribute uniquely to blood conservation, providing important options in comprehensive

  8. [Sodium bicarbonate infusion for intoxication with tricyclic antidepressives: recommended inspite of lack of scientific evidence].

    Science.gov (United States)

    Vrijlandt, P J; Bosch, T M; Zijlstra, J G; Tulleken, J E; Ligtenberg, J J; van der Werf, T S

    2001-09-01

    Sodium bicarbonate infusion is widely recommended in textbooks for patients who present with self-poisoning from tricyclic antidepressives. Cardiac conduction disorders could also be treated or prevented by means of such an infusion. The scientific basis for these recommendations was investigated by using Medline to search for publications about clinical studies that supported the use of sodium carbonate; 111 articles were scrutinized. Observational studies and case reports mention a rapid improvement in hypotension and cardiac arrhythmias following the administration of sodium bicarbonate. Results from animal experiments are contentious; it is not clear whether alkalinisation or the administration of extra sodium causes the effect. Randomized studies in patients have not been carried out. As the toxicity of sodium bicarbonate is low, and its potential benefit appears to be high, we recommend its use, despite the lack of scientific evidence. No recommendations concerning dosing, concentration and the length of the therapy can be provided on the basis of the literature. PMID:11561485

  9. Dialysate sodium and sodium gradient in maintenance hemodialysis: a neglected sodium restriction approach?

    OpenAIRE

    Munoz Mendoza, Jair; Sun, Sumi; Chertow, Glenn M.; Moran, John, (Thesis); Doss, Sheila; Schiller, Brigitte

    2011-01-01

    Background. A higher sodium gradient (dialysate sodium minus pre-dialysis plasma sodium) during hemodialysis (HD) has been associated with sodium loading; however, its role is not well studied. We hypothesized that a sodium dialysate prescription resulting in a higher sodium gradient is associated with increases in interdialytic weight gain (IDWG), blood pressure (BP) and thirst.

  10. Breast milk - pumping and storing

    Science.gov (United States)

    ... a comfortable chair, sink, and electric pump. If pumping at work is going to be hard, build ... up your milk supply. Wash your hands before pumping. Collect breast milk when pumping. You can use: ...

  11. Preparation of a single-state atomic beam by optical pumping and radiative deflection

    International Nuclear Information System (INIS)

    A simple technique for producing a single-state sodium atomic beam is described. A single laser both optically pumps the F = 2 ground-state atoms into m/sub F/ = +2 and deflects the pumped atoms away from residual F = 1 atoms. Data demonstrating the technique are presented, and a practical design for an apparatus based on these principles is described

  12. Propranolol Blocks Cardiac and Neuronal Voltage-Gated Sodium Channels

    OpenAIRE

    AlfredLGeorge; DaoWWang

    2010-01-01

    Propranolol is a widely-used, nonselective ß-adrenergic receptor antagonist with proven efficacy in treating cardiovascular disorders and in the prevention of migraine headaches. At plasma concentrations exceeding those required for ß-adrenergic receptor inhibition, propranolol also exhibits antiarrhythmic (“membrane stabilizing”) effects that are not fully explained by ß-blockade. Previous in vitro studies suggested that propranolol may have local anesthetic effects We directl...

  13. Blunt cardiac rupture.

    Science.gov (United States)

    Martin, T D; Flynn, T C; Rowlands, B J; Ward, R E; Fischer, R P

    1984-04-01

    Blunt injury to the heart ranges from contusion to disruption. This report comprises 14 patients seen during a 6-year period with cardiac rupture secondary to blunt trauma. Eight patients were injured in automobile accidents, two patients were injured in auto-pedestrian accidents, two were kicked in the chest by ungulates, and two sustained falls. Cardiac tamponade was suspected in ten patients. Five patients presented with prehospital cardiac arrest or arrested shortly after arrival. All underwent emergency department thoracotomy without survival. Two patients expired in the operating room during attempted cardiac repair; both had significant extracardiac injury. Seven patients survived, three had right atrial injuries, three had right ventricular injuries, and one had a left atrial injury. Cardiopulmonary bypass was not required for repair of the surviving patients. There were no significant complications from the cardiac repair. The history of significant force dispersed over a relatively small area of the precordium as in a kicking injury from an animal or steering wheel impact should alert the physician to possible cardiac rupture. Cardiac rupture should be considered in patients who present with signs of cardiac tamponade or persistent thoracic bleeding after blunt trauma. PMID:6708151

  14. Biomaterials for cardiac regeneration

    CERN Document Server

    Ruel, Marc

    2015-01-01

    This book offers readers a comprehensive biomaterials-based approach to achieving clinically successful, functionally integrated vasculogenesis and myogenesis in the heart. Coverage is multidisciplinary, including the role of extracellular matrices in cardiac development, whole-heart tissue engineering, imaging the mechanisms and effects of biomaterial-based cardiac regeneration, and autologous bioengineered heart valves. Bringing current knowledge together into a single volume, this book provides a compendium to students and new researchers in the field and constitutes a platform to allow for future developments and collaborative approaches in biomaterials-based regenerative medicine, even beyond cardiac applications. This book also: Provides a valuable overview of the engineering of biomaterials for cardiac regeneration, including coverage of combined biomaterials and stem cells, as well as extracellular matrices Presents readers with multidisciplinary coverage of biomaterials for cardiac repair, including ...

  15. Mathematical cardiac electrophysiology

    CERN Document Server

    Colli Franzone, Piero; Scacchi, Simone

    2014-01-01

    This book covers the main mathematical and numerical models in computational electrocardiology, ranging from microscopic membrane models of cardiac ionic channels to macroscopic bidomain, monodomain, eikonal models and cardiac source representations. These advanced multiscale and nonlinear models describe the cardiac bioelectrical activity from the cell level to the body surface and are employed in both the direct and inverse problems of electrocardiology. The book also covers advanced numerical techniques needed to efficiently carry out large-scale cardiac simulations, including time and space discretizations, decoupling and operator splitting techniques, parallel finite element solvers. These techniques are employed in 3D cardiac simulations illustrating the excitation mechanisms, the anisotropic effects on excitation and repolarization wavefronts, the morphology of electrograms in normal and pathological tissue and some reentry phenomena. The overall aim of the book is to present rigorously the mathematica...

  16. Commissioning of the cleaning loop of sodium contaminated equipment in sodium-cooled fast reactor

    International Nuclear Information System (INIS)

    The water vapor-nitrogen test loop was constructed to study the cleaning technology of sodium contaminated equipment in sodium-cooled fast reactor. The main components of the loop include a liquid nitrogen storage tank, an electric heating steam generator, a cleaning tank, an effluent storage tank, a condenser, a vacuum pump and a hydrogen meter. After a series of commissioning tests, some problems were found and the corresponding improvement measures were taken. The experiment procedure of the loop which was confirmed by the commissioning tests provided a guarantee for the following studies on the cleaning technology of sodium contaminated equipment. A number of experiences gained from the commissioning tests could be used in the equipment cleaning system of China Experimental Fast Reactor (CEFR). (authors)

  17. Hemodynamic and neuroendocrine responses to changes in sodium intake in compensated heart failure

    DEFF Research Database (Denmark)

    Damgaard, Morten; Norsk, Peter; Gustafsson, Finn; Kanters, Jørgen Kim; Christensen, Niels Juel; Bie, Peter; Friberg, Lars; Gadsbøll, Niels

    2006-01-01

    Patients with untreated heart failure (HF) exhibit a blunted hemodynamic and neuroendocrine response to a high sodium intake, leading to excessive sodium and water retention. However, it is not known whether this is the case for patients with compensated HF receiving angiotensin-converting enzyme...... inhibitors and beta-adrenoreceptor blockers. Therefore, we determined the hemodynamic and neuroendocrine responses to 1 wk of a low-sodium diet (70 mmol/day) and 1 wk of a high-sodium diet (250 mmol/day) in 12 HF patients and 12 age-matched controls in a randomized, balanced fashion. During steady...... unchanged. In conclusion, high sodium intake was tolerated without any excessive sodium and water retention in medically treated patients with compensated HF. The observation that high sodium intake improves cardiac performance, induces peripheral vasodilatation, and suppresses the release of...

  18. Chest pain of cardiac and noncardiac origin.

    Science.gov (United States)

    Lenfant, Claude

    2010-10-01

    causes, gastroesophageal disorders are by far the most prevalent, especially gastroesophageal reflux disease. Fortunately, this disease can be diagnosed and treated effectively by proton-pump inhibitors. The other types of non-gastroesophageal reflux disease-related noncardiac chest pain are more difficult to diagnose and treat. In conclusion, the cause of chest pain must be accurately diagnosed; and treatment must be pursued according to the cause, especially if the cause is of cardiac origin. PMID:20837193

  19. Site specific health and safety plan, 100-HR-3 pump and treat. Revision 1

    International Nuclear Information System (INIS)

    The 100-HR-3 Operable Unit encompasses groundwater contamination underlying the 100-D and 100-H Areas. The primary contaminate is chromium VI. The sources of chromium contamination resulted from the use of sodium dichromate during past reactor operations. The purpose of the 100-HR-3 Pump-and-Treat system is to pump contaminated groundwater through aboveground ion exchange resin and then return the treated waster to the aquifer. This plan covers operation, maintenance, repairs, and pump removal/installation

  20. Internal pump monitoring device

    International Nuclear Information System (INIS)

    In the present invention, a thermometer is disposed at the upper end of an internal pump casing of a coolant recycling system in a BWR type reactor to detect leakage of reactor water thereby ensuring the improvement of reliability of the internal pump. Namely, a thermometer is disposed, which can detect temperature elevation occurred when water in the internal pump leaked from a reactor pressure vessel passes through the gap between a stretch tube and an upper end of the pump casing. Signals from the thermometer are transmitted to a signal processing device by an instrumentation cable. The signal processing device generates an alarm when the temperature signal exceeds a predetermined value and announces that leakage of reactor water occurs in the internal pump. Since the present invention can detect the leakage of the reactor water in the pump casing in an early stage, it can contribute to the improvement of the safety and reliability of the internal pump. (I.S.)

  1. Solubilities of sodium nitrate, sodium nitrite, and sodium aluminate in simulated nuclear waste

    International Nuclear Information System (INIS)

    Solubilities were determined for sodium nitrate, sodium nitrite, and sodium aluminate in synthetic nuclear waste liquor. Solubilities were determined as a function of temperature and solution composition (concentrations of sodium hydroxide, sodium nitrate, sodium nitrite, and sodium aluminate). Temperature had the greatest effect on the solubilities of sodium nitrate and sodium nitrite and a somewhat lesser effect on sodium aluminate solubility. Hydroxide had a great effect on the solubilities of all three salts. Other solution components had minor effects. 2 references, 8 figures, 11 tables

  2. Sodium fire suppression

    International Nuclear Information System (INIS)

    Ignition and combustion studies have provided valuable data and guidelines for sodium fire suppression research. The primary necessity is to isolate the oxidant from the fuel, rather than to attempt to cool the sodium below its ignition temperature. Work along these lines has led to the development of smothering tank systems and a dry extinguishing powder. Based on the results obtained, the implementation of these techniques is discussed with regard to sodium fire suppression in the Super-Phenix reactor. (author)

  3. Mercury Toxicity on Sodium Pump and Organoseleniums Intervention: A Paradox

    Directory of Open Access Journals (Sweden)

    Ige Joseph Kade

    2012-01-01

    Full Text Available Mercury is an environmental poison, and the damage to living system is generally severe. The severity of mercury poisoning is consequent from the fact that it targets the thiol-containing enzymes, irreversibly oxidizing their critical thiol groups, consequently leading to an inactivation of the enzyme. The Na+/K+-ATPase is a sulfhydryl protein that is sensitive to Hg2+ assault. On the other hand, organoseleniums are a class of pharmacologically promising compounds with potent antioxidant effects. While Hg2+ oxidizes sulfhydryl groups of Na+/K+-ATPase under in vitro and in vivo conditions, the organoselenium compounds inhibit Na+/K+-ATPase in vitro but enhance its activities under in vivo conditions with concomitant increase in the level of endogenous thiols. Paradoxically, it appears that these two thiol oxidants can be used to counteract one another under in vivo conditions, and this hypothesis serves as the basis for this paper.

  4. Thermophysical properties of sodium

    International Nuclear Information System (INIS)

    Thermophysical properties of sodium for reactor safety studies are presented. Subcooled, superheated and saturated properties are given. A summary of the thermophysical properties is given in tabular form

  5. Off-Pump Coronary Bypass Grafting Causing Stunned Myocardium

    Directory of Open Access Journals (Sweden)

    Feridoun Sabzi

    2015-10-01

    Full Text Available The term “stunned myocardium” refers to abnormalities in the myocardial function following reperfusion and is common in on-pump coronary artery bypass grafting (CABG and is exceedingly rare in off- pump CABG. A 53-year-old man presented with unstable angina due to the severe stenosis of the left anterior descending coronary artery (LAD and the obtuse marginal. Laboratory findings and Chest X-ray revealed nothing abnormal. The intraoperative course was uneventful. The patient left the operating room without any inotropic support. Six hours later, however, he developed low cardiac output .At exploration, cardiac tamponade was excluded and flowmetry showed that the graft had adequate function. Cardiac enzymes were normal. High-dose adrenalin and Dobutamine were administrated and an intra-aortic balloon pump was used. After hemodynamic stabilization, the patient left the Intensive Care Unit without an intra-aortic balloon pump and inotropic support. On the fifth postoperative day, coronary angiography showed patent grafts and correct anastomotic sites. On the seventh postoperative day, the akinetic lateral wall of the left ventricle changed to dyskinesia. Finally after hospital discharge on the thirtieth postoperative day, an echocardiogram showed normal left ventricular function without regional wall motion abnormalities

  6. [Cardiac evaluation before non-cardiac surgery].

    Science.gov (United States)

    Menzenbach, Jan; Boehm, Olaf

    2016-07-01

    Before non-cardiac surgery, evaluation of cardiac function is no frequent part of surgical treatment. European societies of anesthesiology and cardiology published consensus-guidelines in 2014 to present a reasonable approach for preoperative evaluation. This paper intends to differentiate the composite of perioperative risk and to display the guidelines methodical approach to handle it. Features to identify patients at risk from an ageing population with comorbidities, are the classification of surgical risk, functional capacity and risk indices. Application of diagnostic means, should be used adjusted to this risk estimation. Cardiac biomarkers are useful to discover risk of complications or mortality, that cannot be assessed by clinical signs. After preoperative optimization and perioperative cardiac protection, the observation of the postoperative period remains, to prohibit complications or even death. In consideration of limited resources of intensive care department, postoperative ward rounds beyond intensive care units are considered to be an appropriate instrument to avoid or recognize complications early to reduce postoperative mortality. PMID:27479258

  7. Cardiac surgery in a fixed-reimbursement environment.

    Science.gov (United States)

    Scully, H E

    1996-02-01

    Hospital and physician services in Canada are funded by public (government) sources. This article will describe the practice of cardiac surgery in this setting. Federal legislation has prescribed the principles of accessibility, universality, comprehensiveness, portability, and public administration for essential healthcare services in Canada. Provincial and territorial governments are responsible for the provision of services, receiving federal tax and cash transfers that supplement provincial/territorial funds for hospital, physician, and community health services. Hospitals negotiate annually for global budgets. Physicians work as independent contractors in hospitals (and communities) and are usually paid as specified by fee-for-service contracts negotiated at intervals with governments. Cardiac surgical services have been planned conjointly with government. Forty-two centers in Canada serve a population of 28 million. All but three of these centers are located in tertiary teaching hospitals; all but one do more than 200 pumps annually. The rate of cardiac operations is 80 per 100,000 population. In Ontario, the Provincial Adult Cardiac Care Network makes recommendations to governments about the distribution of the 7,600 pumps annually (population, 11 million), rationalizing waiting lists based on an urgency rating scale. Patients requiring emergent/urgent operations are well served. The average waiting time for an elective cardiac operation is 10.5 weeks. The waiting list mortality is less than 0.5%. The Provincial Adult Cardiac Care Network also determines the placement of new programs and participates in creating hospital funding formulas developed from a combination of resource and acuity intensity weighting. Most surgeons hold full-time academic appointments but are funded largely by practice income. Surgical fees average $2,000 (Canada) per case. Overhead, including malpractice insurance, is approximately 45%. All Canadian patients enjoy reasonably timely

  8. Sodium-23 magnetic resonance imaging of the eye and lens

    International Nuclear Information System (INIS)

    In order to develop a better understanding of cataract and to evaluate the effectiveness of potential drugs, noninvasive techniques must be devised to detect early metabolic changes. As a prelude to these goals, sodium-23 imaging experiments operating at 29.8 MHz (2.7 teslas) were performed on the bovine eye and lens. A spatially localized transverse relaxation time (T2)-weighted spin-density map of the sodium-23 within the lens is presented, with a resolution better than 250 μm. Due to the presence of short-T2 (3 msec) components within the lens, only the use of the planar-integral projection reconstruction (PPR) imaging scheme allowed sufficiently short echo-times (1 msec) to permit sodium-23 signal detection. These noninvasive imaging results show differences in the apparent sodium concentration within the lens that are consistent with separate, invasive measurements of sodium concentration. Separate analysis at 79.4 MHz (7.2 teslas), using a shift reagent (dysprosium) to distinguish extracellar from intracellular sodium, indicates that ≅ 62% of the detected sodium-23 signal is intracellular. These results are consistent with observations based on invasive measurements and further support the existence of the pump-leak system and a sodium gradient within the lens

  9. Cardiac metabolism and arrhythmias

    OpenAIRE

    Barth, Andreas S.; Tomaselli, Gordon F.

    2009-01-01

    Sudden cardiac death remains a leading cause of mortality in the Western world, accounting for up to 20% of all deaths in the U.S.1, 2 The major causes of sudden cardiac death in adults age 35 and older are coronary artery disease (70–80%) and dilated cardiomyopathy (10–15%).3 At the molecular level, a wide variety of mechanisms contribute to arrhythmias that cause sudden cardiac death, ranging from genetic predisposition (rare mutations and common polymorphisms in ion channels and structural...

  10. [Cardiac Rehabilitation 2015].

    Science.gov (United States)

    Hoffmann, Andreas

    2015-11-25

    The goals of cardiac rehabilitation are (re-)conditioning and secondary prevention in patients with heart disease or an elevated cardiovascular risk profile. Rehabilitation is based on motivation through education, on adapted physical activity, instruction of relaxation techniques, psychological support and optimized medication. It is performed preferably in groups either in outpatient or inpatient settings. The Swiss working group on cardiac rehabilitation provides a network of institutions with regular quality auditing. Positive effects of rehabilitation programs on mortality and morbidity have been established by numerous studies. Although a majority of patients after cardiac surgery are being referred to rehabilitation, these services are notoriously underused after catheter procedures. PMID:26602848

  11. Comprehensive cardiac rehabilitation

    DEFF Research Database (Denmark)

    Kruse, Marie; Hochstrasser, Stefan; Zwisler, Ann-Dorthe O;

    2006-01-01

    OBJECTIVES: The costs of comprehensive cardiac rehabilitation are established and compared to the corresponding costs of usual care. The effect on health-related quality of life is analyzed. METHODS: An unprecedented and very detailed cost assessment was carried out, as no guidelines existed for...... uncertain and may be as high as euro 1.877. CONCLUSIONS: Comprehensive cardiac rehabilitation is more costly than usual care, and the higher costs are not outweighed by a quality of life gain. Comprehensive cardiac rehabilitation is, therefore, not cost-effective....

  12. Hemodynamic characterization of chronic bile duct-ligated rats: effect of pentobarbital sodium

    International Nuclear Information System (INIS)

    Systemic and splanchnic hemodynamics of the chronic bile duct-ligated rat were characterized by radioactive microspheres. Conscious and pentobarbital sodium-anesthetized, bile duct-ligated and sham-operated rats had cardiac output and regional organ blood flows determined. The conscious bile duct-ligated rat compared with the sham-operated showed a hyperdynamic circulation with an increased cardiac output and portal tributary blood flow. Pentobarbital sodium anesthesia induced marked hemodynamic changes in both sham-operated and bile duct-ligated rats. The latter group was especially sensitive to its effects; thus, comparison of cardiac output and portal tributary blood flow between anesthetized bile duct-ligated and sham-operated rats showed no significant differences. The authors conclude that the rat with cirrhosis due to chronic bile duct ligation is an excellent model for hemodynamic investigations but should be studied in the conscious state, since pentobarbital sodium anesthesia eliminated the hyperdynamic circulation

  13. An Induction Heater for a Sodium Circuit

    International Nuclear Information System (INIS)

    The heating of sodium in high-temperature experimental rigs presents problems of reliability of the heater and in the maintenance of a high degree of sodium containment. The problems are particularly severe when the loop is large and non-isothermal, and high heat inputs are required. The Fuel Element Thermal Test Loop at the Reactor Engineering Laboratory of the United Kingdom Atomic Energy Authority, which was designed for fuel element evaluation in sodium at 650°C, makes use of proven pumps of the electromagnetic linear induction type which are limited to a sodium temperature of 375°C. The sodium test section flow of 350 gal/min is raised to 650°C by a 10-MW heat recuperator and a 400-kW electrical heater which replaces the circuit losses. Experience showed that the use of sheathed mineral-insulated heaters was unsatisfactory for this heater, and an alternative method using mains frequency (50 counts/s) induction was adopted. The heater is in the form of a power transformer, the secondary winding of which is a single short-circuited turn formed by a stainless-steel pipe loop containing the sodium. With suitable lagging and cooling arrangements the iron core and primary windings are maintained at temperatures low enough for normal electrical insulating materials to be used. Conventional methods for the fabrication of the pipe loop circuits are also possible. The design, construction and operation of the induction heater is described. The design balance between the differing requirements of electrical efficiency, hydraulic pressure drop, and the geometry imposed by the space available in the rig is discussed. Suggestions for improving these factors at the expense of others are given. The performance of the heater is given and compared with the predicted performance. (author)

  14. Molecular Basis of Cardiac Myxomas

    Directory of Open Access Journals (Sweden)

    Pooja Singhal

    2014-01-01

    Full Text Available Cardiac tumors are rare, and of these, primary cardiac tumors are even rarer. Metastatic cardiac tumors are about 100 times more common than the primary tumors. About 90% of primary cardiac tumors are benign, and of these the most common are cardiac myxomas. Approximately 12% of primary cardiac tumors are completely asymptomatic while others present with one or more signs and symptoms of the classical triad of hemodynamic changes due to intracardiac obstruction, embolism and nonspecific constitutional symptoms. Echocardiography is highly sensitive and specific in detecting cardiac tumors. Other helpful investigations are chest X-rays, magnetic resonance imaging and computerized tomography scan. Surgical excision is the treatment of choice for primary cardiac tumors and is usually associated with a good prognosis. This review article will focus on the general features of benign cardiac tumors with an emphasis on cardiac myxomas and their molecular basis.

  15. Sodium recovery vessel

    International Nuclear Information System (INIS)

    Purpose: To enable to efficiently separate and recover sodium or reaction product in the secondly coolant circuit of FBR type nuclear power plant. Constitution: an upper element is disposed above a cyclone in a sodium recovery vessel, to which a gas formed by sodium-water reaction is caused to flow. Sodium and gases formed by sodium-water reaction introduced from a gas inlet of pressure open system pipeways descend downwardly as swirling stream in a cylindrical vessel within the circumferential flow channel along the outer wall of the shround surrounding the cyclone and the inner wall of the cylindrical vessel. In this case, liquid sodium is separated from the gas, falls to the bottom of the cylindrical vessel as an accumulated liquid. The gas stream passes between each of the elements in the upper element to enable separation of sodium or reaction product, as well as separated sodium and reaction product are urged to the outer circumferential side since all of the upper element and the buffer plate are arranged with their outer circumferential being lowered. (Horiuchi, T.)

  16. Visibility in sodium fume

    International Nuclear Information System (INIS)

    The appearance of sodium fume of unknown concentration and the effects of short term exposure on unprotected workers is described. The molecular extinction coefficient of sodium fume is calculated from which light transmission data, and a rapid method for the estimation of the fume concentration is proposed. (author)

  17. Annular sodium flowsensor

    International Nuclear Information System (INIS)

    This paper describes a unique eddy-current type liquid sodium flowsensor, designed as a joint effort between Argonne National Laboratory and Kaman Instrumentation Corp. Test results are included for operation of the flowsensor mounted on a sodium test loop whose configuration simulates the actual operating conditions, except for the magnetic field of the ALIP

  18. Sodium concrete reactions

    International Nuclear Information System (INIS)

    The data from an extensive series of sodium/concrete reaction tests are presented and mechanisms by which the reactions proceed are analyzed. The results indicate water transport and the resulting sodium/water reaction dominate both the chemical energy release and H2 generation. A mechanism which explains the limited penetration of concrete observed in most of these tests is proposed

  19. Pump application and maintenance

    International Nuclear Information System (INIS)

    Nuclear maintenance programs are typically organized by overall application, function, cost impact, and failure histories. Each maintenance program is uniquely tailored for each plant's specific goals and objectives. Most maintenance programs include pump maintenance within an application and/or a function. NMAC provides guidance on maintenance, troubleshooting, and applications of Deep Draft Vertical Centrifugal Pumps, Main Coolant Pump Seals, Feedwater Pumps, and Charging Pumps. Each maintenance guide includes a technical discussion of the design and operating issues which influence pump and component performance, reliability, and availability. The guides also discuss comprehensive inspection and corresponding repair Advisory groups consisting of utility, manufacturer, and regulatory representatives oversee the development of the NMAC guides, and review by utility personnel further augments the development process

  20. Electrokinetic pumps and actuators

    International Nuclear Information System (INIS)

    Flow and ionic transport in porous media are central to electrokinetic pumping as well as to a host of other microfluidic devices. Electrokinetic pumping provides the ability to create high pressures (to over 10,000 psi) and high flow rates (over 1 mL/min) with a device having no moving parts and all liquid seals. The electrokinetic pump (EKP) is ideally suited for applications ranging from a high pressure integrated pump for chip-scale HPLC to a high flow rate integrated pump for forced liquid convection cooling of high-power electronics. Relations for flow rate and current fluxes in porous media are derived that provide a basis for analysis of complex microfluidic systems as well as for optimization of electrokinetic pumps

  1. Fakir fuel pump

    Science.gov (United States)

    1922-01-01

    In designing the Fakir fuel pump, the fundamental idea was to obtain a simple and reliable method of conveying the fuel from a low tank to the carburetor, with the avoidance of the faults of all former methods and the simultaneous warming of the fuel by means of the heat of compression generated. The principle of the Fakir fuel pump rests on the well-known principle of the diaphragm pump, which must be suitably adapted to the present purpose.

  2. Detection of pump degradation

    Energy Technology Data Exchange (ETDEWEB)

    Greene, R.H.; Casada, D.A.; Ayers, C.W. [and others

    1995-08-01

    This Phase II Nuclear Plant Aging Research study examines the methods of detecting pump degradation that are currently employed in domestic and overseas nuclear facilities. This report evaluates the criteria mandated by required pump testing at U.S. nuclear power plants and compares them to those features characteristic of state-of-the-art diagnostic programs and practices currently implemented by other major industries. Since the working condition of the pump driver is crucial to pump operability, a brief review of new applications of motor diagnostics is provided that highlights recent developments in this technology. The routine collection and analysis of spectral data is superior to all other technologies in its ability to accurately detect numerous types and causes of pump degradation. Existing ASME Code testing criteria do not require the evaluation of pump vibration spectra but instead overall vibration amplitude. The mechanical information discernible from vibration amplitude analysis is limited, and several cases of pump failure were not detected in their early stages by vibration monitoring. Since spectral analysis can provide a wealth of pertinent information concerning the mechanical condition of rotating machinery, its incorporation into ASME testing criteria could merit a relaxation in the monthly-to-quarterly testing schedules that seek to verify and assure pump operability. Pump drivers are not included in the current battery of testing. Operational problems thought to be caused by pump degradation were found to be the result of motor degradation. Recent advances in nonintrusive monitoring techniques have made motor diagnostics a viable technology for assessing motor operability. Motor current/power analysis can detect rotor bar degradation and ascertain ranges of hydraulically unstable operation for a particular pump and motor set. The concept of using motor current or power fluctuations as an indicator of pump hydraulic load stability is presented.

  3. Detection of pump degradation

    International Nuclear Information System (INIS)

    This Phase II Nuclear Plant Aging Research study examines the methods of detecting pump degradation that are currently employed in domestic and overseas nuclear facilities. This report evaluates the criteria mandated by required pump testing at U.S. nuclear power plants and compares them to those features characteristic of state-of-the-art diagnostic programs and practices currently implemented by other major industries. Since the working condition of the pump driver is crucial to pump operability, a brief review of new applications of motor diagnostics is provided that highlights recent developments in this technology. The routine collection and analysis of spectral data is superior to all other technologies in its ability to accurately detect numerous types and causes of pump degradation. Existing ASME Code testing criteria do not require the evaluation of pump vibration spectra but instead overall vibration amplitude. The mechanical information discernible from vibration amplitude analysis is limited, and several cases of pump failure were not detected in their early stages by vibration monitoring. Since spectral analysis can provide a wealth of pertinent information concerning the mechanical condition of rotating machinery, its incorporation into ASME testing criteria could merit a relaxation in the monthly-to-quarterly testing schedules that seek to verify and assure pump operability. Pump drivers are not included in the current battery of testing. Operational problems thought to be caused by pump degradation were found to be the result of motor degradation. Recent advances in nonintrusive monitoring techniques have made motor diagnostics a viable technology for assessing motor operability. Motor current/power analysis can detect rotor bar degradation and ascertain ranges of hydraulically unstable operation for a particular pump and motor set. The concept of using motor current or power fluctuations as an indicator of pump hydraulic load stability is presented

  4. The Insulin Pump

    OpenAIRE

    Toews, C. J.

    1985-01-01

    Subcutaneous continuous insulin infusion systems deliver insulin at a basal rate designed to keep blood glucose levels normal in the non-fed state. Additional insulin is delivered at meal time. Pumps can provide near optimal control of blood glucose concentrations in selected, highly motivated patients. The pump provides better diabetic control than once daily insulin injections, although several daily injections can provide comparable control. Optimal control with the pump causes some short-...

  5. Automatic Implantable Cardiac Defibrillator

    Medline Plus

    Full Text Available Automatic Implantable Cardiac Defibrillator February 19, 2009 Halifax Health Medical Center, Daytona Beach, FL Welcome to Halifax Health Daytona Beach, Florida. Over the next hour you' ...

  6. Sudden Cardiac Arrest

    Science.gov (United States)

    ... Heart Risk Factors & Prevention Heart Diseases & Disorders Atrial Fibrillation (AFib) Sudden Cardiac Arrest (SCA) SCA: Who's At Risk? Prevention of SCA What Causes SCA? SCA Awareness Atrial Flutter Heart Block Heart Failure Sick Sinus Syndrome Substances & Heart Rhythm Disorders Symptoms & ...

  7. Sudden cardiac death

    Directory of Open Access Journals (Sweden)

    Aranđelović Aleksandra Č.

    2004-01-01

    Full Text Available Sudden cardiac death in an athlete is rare and tragic event. An athlete's death draws high public attention given that athletes are considered the healthiest category of society. The vast majority of sudden cardiac death in young athletes is due to congenital cardiac malformations such as hypertrophie cardiomyopathy and various coronary artery anomalies. In athletes over age 35, the usual cause of sudden cardiac death is coronary artery disease. With each tragic death of a young athlete, there is a question why this tragedy has not been prevented. The American College of Sports Medicine and the American Heart Association recommend that a pre-participation exam should include a complete cardiovascular history and physical examination.

  8. Cardiac Risk Assessment

    Science.gov (United States)

    ... to assess cardiac risk include: High-sensitivity C-reactive protein (hs-CRP) : Studies have shown that measuring ... LDL-C but does not respond to typical strategies to lower LDL-C such as diet, exercise, ...

  9. Cardiac arrest - cardiopulmonary resuscitation

    Institute of Scientific and Technical Information of China (English)

    Basri Lenjani; Besnik Elshani; Nehat Baftiu; Kelmend Pallaska; Kadir Hyseni; Njazi Gashi; Nexhbedin Karemani; Ilaz Bunjaku; Taxhidin Zaimi; Arianit Jakupi

    2014-01-01

    Objective:To investigate application of cardiopulmonary resuscitation(CPR) measures within the golden minutes inEurope.Methods:The material was taken from theUniversityClinical Center ofKosovo -EmergencyCentre inPristina, during the two(2) year period(2010-2011).The collected date belong to the patients with cardiac arrest have been recorded in the patients' log book protocol at the emergency clinic.Results:During the2010 to2011 in the emergency center of theCUCK inPristina have been treated a total of269 patients with cardiac arrest, of whom159 or59.1% have been treated in2010, and110 patients or40.9% in2011.Of the269 patients treated in the emergency centre,93 or34.6% have exited lethally in the emergency centre, and176 or 65.4% have been transferred to other clinics.In the total number of patients with cardiac arrest, males have dominated with186 cases, or69.1%.The average age of patients included in the survey was56.7 year oldSD±16.0 years.Of the269 patients with cardiac arrest, defibrillation has been applied for93 or34.6% of patients.In the outpatient settings defibrillation has been applied for3 or3.2% of patients.Patients were defibrillated with application of one to four shocks. Of27 cases with who have survived cardiac arrest, none of them have suffered cardiac arrest at home,3 or11.1% of them have suffered cardiac arrest on the street, and24 or88.9% of them have suffered cardiac arrest in the hospital.5 out of27 patients survived have ended with neurological impairment.Cardiac arrest cases were present during all days of the week, but frequently most reported cases have been onMonday with32.0% of cases, and onFriday with24.5% of cases. Conclusions:All survivors from cardiac arrest have received appropriate medical assistance within10 min from attack, which implies that if cardiac arrest occurs near an institution health care(with an opportunity to provide the emergent health care) the rate of survival is higher.

  10. Optically pumped atoms

    CERN Document Server

    Happer, William; Walker, Thad

    2010-01-01

    Covering the most important knowledge on optical pumping of atoms, this ready reference is backed by numerous examples of modelling computation for optical pumped systems. The authors show for the first time that modern scientific computing software makes it practical to analyze the full, multilevel system of optically pumped atoms. To make the discussion less abstract, the authors have illustrated key points with sections of MATLAB codes. To make most effective use of contemporary mathematical software, it is especially useful to analyze optical pumping situations in the Liouville spa

  11. Detection of pump degradation

    Energy Technology Data Exchange (ETDEWEB)

    Casada, D. [Oak Ridge National Lab., TN (United States)

    1995-04-01

    There are a variety of stressors that can affect the operation of centrifugal pumps. Although these general stressors are active in essentially all centrifugal pumps, the stressor level and the extent of wear and degradation can vary greatly. Parameters that affect the extent of stressor activity are manifold. In order to assure the long-term operational readiness of a pump, it is important to both understand the nature and magnitude of the specific degradation mechanisms and to monitor the performance of the pump. The most commonly applied method of monitoring the condition of not only pumps, but rotating machinery in general, is vibration analysis. Periodic or continuous special vibration analysis is a cornerstone of most pump monitoring programs. In the nuclear industry, non-spectral vibration monitoring of safety-related pumps is performed in accordance with the ASME code. Pump head and flow rate are also monitored, per code requirements. Although vibration analysis has dominated the condition monitoring field for many years, there are other measures that have been historically used to help understand pump condition; advances in historically applied technologies and developing technologies offer improved monitoring capabilities. The capabilities of several technologies (including vibration analysis, dynamic pressure analysis, and motor power analysis) to detect the presence and magnitude of both stressors and resultant degradation are discussed.

  12. Ground Source Heat Pumps

    OpenAIRE

    Lale Valizade

    2013-01-01

    A heat pump is a device that is able to transfer heat from one fluid at a lower temperature to another at a higher temperature. Ground source heat pumps are generally classified by the type of ground loop. The coefficient of performance (COP) is used to define the heating performance of heat pumps. Both the COP and EER values are valid only at the specific test conditions used in the rating. A ground source pump could reach 450%, compared with an efficient gas boiler of 90% obviously this is ...

  13. Awareness in cardiac anesthesia.

    LENUS (Irish Health Repository)

    Serfontein, Leon

    2010-02-01

    Cardiac surgery represents a sub-group of patients at significantly increased risk of intraoperative awareness. Relatively few recent publications have targeted the topic of awareness in this group. The aim of this review is to identify areas of awareness research that may equally be extrapolated to cardiac anesthesia in the attempt to increase understanding of the nature and significance of this scenario and how to reduce it.

  14. Safety in cardiac surgery

    OpenAIRE

    Siregar, S.

    2013-01-01

    The monitoring of safety in cardiac surgery is a complex process, which involves many clinical, practical, methodological and statistical issues. The objective of this thesis was to measure and to compare safety in cardiac surgery in The Netherlands using the Netherlands Association for Cardio-Thoracic Surgery (NVT) database. The safety of care is usually measured using patient outcomes. If outcomes are not available, the process and structure of care may be used. Outcomes should be adjusted ...

  15. Cardiac rehabilitation in Germany.

    Science.gov (United States)

    Karoff, Marthin; Held, Klaus; Bjarnason-Wehrens, Birna

    2007-02-01

    The purpose of this review is to give an overview of the rehabilitation measures provided for cardiac patients in Germany and to outline its legal basis and outcomes. In Germany the cardiac rehabilitation system is different from rehabilitation measures in other European countries. Cardiac rehabilitation in Germany since 1885 is based on specific laws and the regulations of insurance providers. Cardiac rehabilitation has predominantly been offered as an inpatient service, but has recently been complemented by outpatient services. A general agreement on the different indications for offering these two services has yet to be reached. Cardiac rehabilitation is mainly offered after an acute cardiac event and bypass surgery. It is also indicated in severe heart failure and special cases of percutaneous coronary intervention. Most patients are men (>65%) and the age at which events occur is increasing. The benefits obtained during the 3-4 weeks after an acute event, and confirmed in numerous studies, are often later lost under 'usual care' conditions. Many attempts have been made by rehabilitation institutions to improve this deficit by providing intensive aftercare. One instrument set up to achieve this is the nationwide institution currently comprising more than 6000 heart groups with approximately 120000 outpatients. After coronary artery bypass grafting or acute coronary syndrome cardiac rehabilitation can usually be started within 10 days. The multidisciplinary rehabilitation team consists of cardiologists, psychologists, exercise therapists, social workers, nutritionists and nurses. The positive effects of cardiac rehabilitation are also important economically, for example, for the improvement of secondary prevention and vocational integration. PMID:17301623

  16. Ranolazine in Cardiac Arrhythmia.

    Science.gov (United States)

    Saad, Marwan; Mahmoud, Ahmed; Elgendy, Islam Y; Richard Conti, C

    2016-03-01

    Ranolazine utilization in the management of refractory angina has been established by multiple randomized clinical studies. However, there is growing evidence showing an evolving role in the field of cardiac arrhythmias. Multiple experimental and clinical studies have evaluated the role of ranolazine in prevention and management of atrial fibrillation, with ongoing studies on its role in ventricular arrhythmias. In this review, we will discuss the pharmacological, experimental, and clinical evidence behind ranolazine use in the management of various cardiac arrhythmias. PMID:26459200

  17. Cardiac tumours in infancy

    OpenAIRE

    Yadava, O.P.

    2012-01-01

    Cardiac tumours in infancy are rare and are mostly benign with rhabdomyomas, fibromas and teratomas accounting for the majority. The presentation depends on size and location of the mass as they tend to cause cavity obstruction or arrhythmias. Most rhabdomyomas tend to regress spontaneously but fibromas and teratomas generally require surgical intervention for severe haemodynamic or arrhythmic complications. Other relatively rare cardiac tumours too are discussed along with an Indian perspect...

  18. Neuromuscular blockade in cardiac surgery: An update for clinicians

    Directory of Open Access Journals (Sweden)

    Hemmerling Thomas

    2008-01-01

    Full Text Available There have been great advancements in cardiac surgery over the last two decades; the widespread use of off-pump aortocoronary bypass surgery, minimally invasive cardiac surgery, and robotic surgery have also changed the face of cardiac anaesthesia. The concept of "Fast-track anaesthesia" demands the use of nondepolarising neuromuscular blocking drugs with short duration of action, combining the ability to provide (if necessary sufficiently profound neuromuscular blockade during surgery and immediate re-establishment of normal neuromuscular transmission at the end of surgery. Postoperative residual muscle paralysis is one of the major hurdles for immediate or early extubation after cardiac surgery. Nondepolarising neuromuscular blocking drugs for cardiac surgery should therefore be easy to titrate, of rapid onset and short duration of action with a pathway of elimination independent from hepatic or renal dysfunction, and should equally not affect haemodynamic stability. The difference between repetitive bolus application and continuous infusion is outlined in this review, with the pharmacodynamic and pharmacokinetic characteristics of vecuronium, pancuronium, rocuronium, and cisatracurium. Kinemyography and acceleromyography are the most important currently used neuromuscular monitoring methods. Whereas monitoring at the adductor pollicis muscle is appropriate at the end of surgery, monitoring of the corrugator supercilii muscle better reflects neuromuscular blockade at more central, profound muscles, such as the diaphragm, larynx, or thoraco-abdominal muscles. In conclusion, cisatracurium or rocuronium is recommended for neuromuscular blockade in modern cardiac surgery.

  19. Stability of colistimethate sodium in a disposable elastomeric infusion device.

    Science.gov (United States)

    Abdulla, Alan; van Leeuwen, Roelof W F; de Vries Schultink, Aurelia H M; Koch, Birgit C P

    2015-01-01

    Infections of the respiratory tract with Pseudomonas aeruginosa in cystic fibrosis patients are frequently treated with colistimethate sodium (CMS). For the intravenous administration of CMS a disposable elastomeric pump is a convenient option. To date, there are no data available on the chemical stability of CMS solutions stored in elastomeric pumps. We evaluated the chemical stability of 0.8 mg/mL solutions of CMS by measuring the degradation over a period of 7 days. Test samples were prepared by diluting CMS with saline solution (0.9%). The preparations were transferred to 100-mL elastomeric pumps and stored at 4 °C. The chemical stability was measured by a high-performance liquid chromatography method with UV detection. There was no degradation of CMS (elastomeric pump. PMID:25863116

  20. Cardiac Image Registration

    Directory of Open Access Journals (Sweden)

    2008-09-01

    Full Text Available Long procedure time and somewhat suboptimal results hinder the widespread use of catheter ablation of complex arrhythmias such as atrial fibrillation (AF. Due to lack of contrast differentiation between the area of interest and surrounding structures in a moving organ like heart, there is a lack of proper intraprocedural guidance using current imaging techniques for ablation. Cardiac image registration is currently under investigation and is in clinical use for AF ablation. Cardiac image registration, which involves integration of two images in the context of left atrium (LA, is intermodal, with the acquired image and the real-time reference image residing in different image spaces, and involves optimization, where one image space is transformed into the other. Unlike rigid body registration, cardiac image registration is unique and challenging due to cardiac motion during the cardiac cycle and due to respiration. This review addresses the basic principles of the emerging technique of registration and the inherent limitations as they relate to cardiac imaging and registration.

  1. Cardiac Image Registration

    Directory of Open Access Journals (Sweden)

    Jasbir Sra

    2008-09-01

    Full Text Available Long procedure time and somewhat suboptimal results hinder the widespread use of catheter ablation of complex arrhythmias such as atrial fibrillation (AF. Due to lack of contrast differentiation between the area of interest and surrounding structures in a moving organ like heart, there is a lack of proper intraprocedural guidance using current imaging techniques for ablation. Cardiac image registration is currently under investigation and is in clinical use for AF ablation. Cardiac image registration, which involves integration of two images in the context of the left atrium (LA, is intermodal, with the acquired image and the real-time reference image residing in different image spaces, and involves optimization, where one image space is transformed into the other. Unlike rigid body registration, cardiac image registration is unique and challenging due to cardiac motion during the cardiac cycle and due to respiration. This review addresses the basic principles of the emerging technique of registration and the inherent limitations as they relate to cardiac imaging and registration.

  2. Incidence and management of diaphragmatic palsy in patients after cardiac surgery

    OpenAIRE

    Mehta Yatin; Vats Mayank; Singh Ajmer; Trehan Naresh

    2008-01-01

    Background: Diaphragm is the most important part of the respiratory system. Diaphragmatic palsy following cardiac surgery is not uncommon and can cause deterioration of pulmonary functions and attendant pulmonary complications. Objectives: Aim of this study was to observe the incidence of diaphragmatic palsy after off pump coronary artery bypass grafting (OPCAB) as compared to conventional CABG and to assess the efficacy of chest physiotherapy on diaphragmatic palsy in post cardiac surgica...

  3. METHOD FOR REMOVING SODIUM OXIDE FROM LIQUID SODIUM

    Science.gov (United States)

    Bruggeman, W.H.; Voorhees, B.G.

    1957-12-01

    A method is described for removing sodium oxide from a fluent stream of liquid sodium by coldtrapping the sodium oxide. Apparatus utilizing this method is disclosed in United States Patent No. 2,745,552. Sodium will remain in a molten state at temperatures below that at which sodium oxide will crystallize out and form solid deposits, therefore, the contaminated stream of sodium is cooled to a temperature at which the solubility of sodium oxide in sodium is substantially decreased. Thereafter the stream of sodium is passed through a bed of stainless steel wool maintained at a temperature below that of the stream. The stream is kept in contact with the wool until the sodium oxide is removed by crystal growth on the wool, then the stream is reheated and returned to the system. This method is useful in purifying reactor coolants where the sodium oxide would otherwise deposit out on the walls and eventually plug the coolant tubes.

  4. Postoperative cardiac arrest due to cardiac surgery complications

    International Nuclear Information System (INIS)

    To examine the role of anesthetists in the management of cardiac arrest occurring in association with cardiac anesthesia. In this retrospective study we studied the potential performances for each of the relevant incidents among 712 patients undergoing cardiac operations at Golestan and Naft Hospitals Ahwaz between November 2006 and July 2008. Out of total 712 patients undergoing cardiac surgery, cardiac arrest occurred in 28 cases (3.9%) due to different postoperative complications. This included massive bleeding (50% of cardiac arrest cases, 1.9% of patients); pulseless supra ventricular tachycardia (28.5% of cardiac arrest cases, 1.1% of patients); Heart Failure (7% of cardiac arrest cases, 0.2% of patients); Aorta Arc Rapture (3.5% of cardiac arrest cases, 0.1% of patients); Tamponade due to pericardial effusion (3.5% of cardiac arrest cases, 0.1% of total patients); Right Atrium Rupture (3.5% of cardiac arrest cases, 0.1% of patients) were detected after cardiac surgery. Out of 28 cases 7 deaths occurred (25% of cardiac arrest cases, 0.1% of patients). The most prevalent reason for cardiac arrest during post operative phase was massive bleeding (50%) followed by pulseless supra ventricular tachycardia (28.5%). Six patients had some morbidity and the remaining 15 patients recovered. There are often multiple contributing factors to a cardiac arrest under cardiac anesthesia, as much a complete systematic assessment of the patient, equipment, and drugs should be completed. We also found that the diagnosis and management of cardiac arrest in association with cardiac anesthesia differs considerably from that encountered elsewhere. (author)

  5. Liquid pump for astronaut cooling

    Science.gov (United States)

    Carson, M. A.

    1972-01-01

    The Apollo portable life support system water-recirculation pump used for astronaut cooling is described. The problems associated with an early centrifugal pump and how these problems were overcome by the use of a new diaphragm pump are discussed. Performance comparisons of the two pump designs are given. Developmental problems and flight results with the diaphragm pump are discussed.

  6. The Analysis of an End Effect according to the Input Frequency Change in the EM Pump

    International Nuclear Information System (INIS)

    In general, an electromagnetic (EM) pump is considered to circulate a liquid sodium coolant for a Sodium Fast Reactor (SFR). The EM pump has an end effect at both ends basically due to its finite core length. The generated magnetic field across the flow gap is distorted at both ends of the pump. Consequently, there arises reduction on the developed force by the vector product of that magnetic field and its perpendicular induced current. Especially, it experiences even the opposite pumping force near the pump inlet. That causes low efficiency of the pump and resultantly brings about bad performance of a pump. The present study theoretically shows that this end effect can be lessened by control of input frequency. It is predicted that pump operates much more efficiently in the range of low frequency around teen hertz than in that of high frequency over 60 Hz. The force density is investigated in the narrow annular channel of the pump with the length of 84cm according to pump axial coordinates at various frequency

  7. Flame photometric detection of sodium leaks: Tests on a fullscale model for the control gear sodium rig

    International Nuclear Information System (INIS)

    The proposed arrangement for detecting sodium leaks from the large flanges of the Control Gear Sodium Rig (Test Section No. 8, MCTR) at REML is to jacket then in a secondary containment from which air samples will be continuously pumped. Pipework feeds the air to a flame photometer which responds if soditun is present. To prove that sodium smoke could be transferred through the system, tests were performed on a fullscale model by burning small amounts of sodium in different jackets. Large signals free from fluctuations were obtained in all tests, peak response occurring in 2 1/4 minutes or less. The signal quickly cleared after isolating the appropriate vessel. A waiting period of several hours was sufficient to reduce the signal to zero, no cleaning of pipework, etc being necessary. In contrast, samples of two lagging materials heated to 400 °C gave no response with the photometer at maximum sensitivity. (author)

  8. Cardiac arrhythmia and heart failure: From bench to bedside

    Institute of Scientific and Technical Information of China (English)

    Yong-Fu Xiao

    2011-01-01

    @@ Cardiac arrhythmia is an abnormal rate and/or rhythm of a heart due to its abnormal electrical impulse origination and/or propagation.Various etiologies can cause arrhythnuas.Heart failure(HF)is a clinical syndrome due to an impaired heart that can not pump sufficient blood to meet the systemic metabolic needs.The common causes of HF include myocardial infarction,hypertension,valvular heart disease,and cardiomyopathy.

  9. Optimal Magnetic Sensor Vests for Cardiac Source Imaging

    OpenAIRE

    Stephan Lau; Bojana Petković; Jens Haueisen

    2016-01-01

    Magnetocardiography (MCG) non-invasively provides functional information about the heart. New room-temperature magnetic field sensors, specifically magnetoresistive and optically pumped magnetometers, have reached sensitivities in the ultra-low range of cardiac fields while allowing for free placement around the human torso. Our aim is to optimize positions and orientations of such magnetic sensors in a vest-like arrangement for robust reconstruction of the electric current distributions in t...

  10. THE INVESTIGATION OF THE INTERACTION OF THE IMPLANTABLE ROTARY BLOOD PUMP AND THE LEFT VENTRICLE ON THE MOCK CIRCULATION SYSTEM

    Directory of Open Access Journals (Sweden)

    E. G. Konysheva

    2010-01-01

    Full Text Available We analyzed the dynamics of the interaction of rotary pump, connected to the scheme «the left ventricle – aor- ta», and left ventricle in norms and heart failure, using data obtained on the mock circulatory system. Adverse pumping states such as suction and regurgitation can be detected. These limits depend on the degree of cardiac failure, which confirms the need to control the speed of rotation of the impeller in the range of the cardiac failure from pathology to normal. It has been shown that the pulsating pressure at the inlet of the pump modulates the flow of the pump, making it a pulsating, what positively affects on the dynamics of cardiac output. 

  11. Redox-dependent regulation of the Na⁺-K⁺ pump

    DEFF Research Database (Denmark)

    Liu, Chia-Chi; Fry, Natasha A S; Hamilton, Elisha J;

    2013-01-01

    By the time it was appreciated that the positive inotropic effect of cardiac glycosides is due to inhibition of the membrane Na(+)-K(+) pump, glycosides had been used for treatment of heart failure on an empiric basis for ~200 years. The subsequent documentation of their lack of clinical efficacy...... exploration of future treatment strategies. This article is part of a Special Issue entitled "Na(+)Regulation in Cardiac Myocytes"....

  12. Sodium technology project

    International Nuclear Information System (INIS)

    The 1976 annual report of the subgroup Nuclear Energy of the organisation for Toegepast Natuurwetenschappelijk Onderzoek (TNO) discusses the research program related to the SNR-300 reactor. The program mainly comprises the properties of ferritic and austenitic construction steels, remote methods of repair (e.g. for welding of sodium moistured surfaces), calculational methods in the designing and large-scale testing of components for heat-transfer equipment, the properties of hydrogen in sodium systems (detection of leaks in steam generator pipes), the study of models for mass transport in sodium, wear and mechanical damage of pipes in heat exchangers

  13. Developments in sodium technology

    International Nuclear Information System (INIS)

    Sodium, because of its good heat transfer and nuclear properties, is used as a coolant in fast reactors. It is also used largely as a reducing agent in pharmaceutical, perfumery and general chemical industries. Its affinity to react with air and water is a strong disadvantage. However, this is fully understood and the design of engineering systems takes care of this aspect. With several experimental and test facilities established over the years in this country and abroad, 'sodium technology' has reached a level of maturity. The design of sodium systems considering all the physical and chemical properties and the development work carried out in this country are broadly covered in this article. (author)

  14. A Literature Review of the Use of Sodium Bicarbonate for the Treatment of QRS Widening.

    Science.gov (United States)

    Bruccoleri, Rebecca E; Burns, Michele M

    2016-03-01

    Sodium bicarbonate is a well-known antidote for tricyclic antidepressant (TCA) poisoning. It has been used for over half a century to treat toxin-induced sodium channel blockade as evidenced by QRS widening on the electrocardiogram (ECG). The purpose of this review is to describe the literature regarding electrophysiological mechanisms and clinical use of this antidote after poisoning by tricyclic antidepressants and other agents. This article will also address the literature supporting an increased serum sodium concentration, alkalemia, or the combination of both as the responsible mechanism(s) for sodium bicarbonate's antidotal properties. While sodium bicarbonate has been used as a treatment for cardiac sodium channel blockade for multiple other agents including citalopram, cocaine, flecainide, diphenhydramine, propoxyphene, and lamotrigine, it has uncertain efficacy with bupropion, propranolol, and taxine-containing plants. PMID:26159649

  15. Cardiac and systemic haemodynamic complications of liver cirrhosis

    DEFF Research Database (Denmark)

    Henriksen, Jens H; Møller, Søren

    2009-01-01

    physical and pharmacological strain. Cardiac failure is an important cause of mortality after liver transplantation and stressful procedures as insertions of transjugular intrahepatic portal systemic shunt (TIPS), peritoneal venous shunting, and other types of surgery. Improvement of liver function has......Cardiovascular complications of liver cirrhosis include cardiac dysfunction and abnormalities in the central-, splanchnic,- and peripheral circulation. Vasodilatation prevails, but vascular beds with various degrees of reduced and increased haemodynamic resistance are the results of massive...... been shown to reverse the cardiovascular complications. The clinical significance is an important topic for future research. At present, no specific treatment can be recommended, and the cardiac failure in cirrhosis should be treated as in non-cirrhotic patients with sodium restriction, diuretics, and...

  16. Water Treatment Technology - Pumps.

    Science.gov (United States)

    Ross-Harrington, Melinda; Kincaid, G. David

    One of twelve water treatment technology units, this student manual on pumps provides instructional materials for three competencies. (The twelve units are designed for a continuing education training course for public water supply operators.) The competencies focus on the following areas: types of pumps in plant and distribution systems, pump…

  17. Detection of pump degradation

    International Nuclear Information System (INIS)

    There are a variety of stressors that can affect the operation of centrifugal pumps. Although these general stressors are active in essentially all centrifugal pumps, the stressor level and the extent of wear and degradation can vary greatly. Parameters that affect the extent of stressor activity are manifold. In order to assure the long-term operational readiness of a pump, it is important to both understand the nature and magnitude of the specific degradation mechanisms and to monitor the performance of the pump. The most commonly applied method of monitoring the condition of not only pumps, but rotating machinery in general, is vibration analysis. Periodic or continuous spectral vibration analysis is a cornerstone of most pump monitoring programs. In the nuclear industry, non-spectral vibration monitoring of safety-related pumps is performed in accordance with the ASME code. Although vibration analysis has dominated the condition monitoring field for many years, there are other measures that have been historically used to help understand pump condition: advances in historically applied technologies and developing technologies offer improved monitoring capabilities. The capabilities of several technologies (including vibration analysis, dynamic pressure analysis, and motor power analysis) to detect the presence and magnitude of both stressors and resultant degradation are discussed

  18. Normetex Pump Alternatives Study

    Energy Technology Data Exchange (ETDEWEB)

    Clark, Elliot A.

    2013-04-25

    A mainstay pump for tritium systems, the Normetex scroll pump, is currently unavailable because the Normetex company went out of business. This pump was an all-metal scroll pump that served tritium processing facilities very well. Current tritium system operators are evaluating replacement pumps for the Normetex pump and for general used in tritium service. An all-metal equivalent alternative to the Normetex pump has not yet been identified. 1. The ideal replacement tritium pump would be hermetically sealed and contain no polymer components or oils. Polymers and oils degrade over time when they contact ionizing radiation. 2. Halogenated polymers (containing fluorine, chlorine, or both) and oils are commonly found in pumps. These materials have many properties that surpass those of hydrocarbon-based polymers and oils, including thermal stability (higher operating temperature) and better chemical resistance. Unfortunately, they are less resistant to degradation from ionizing radiation than hydrocarbon-based materials (in general). 3. Polymers and oils can form gaseous, condensable (HF, TF), liquid, and solid species when exposed to ionizing radiation. For example, halogenated polymers form HF and HCl, which are extremely corrosive upon reaction with water. If a pump containing polymers or oils must be used in a tritium system, the system must be designed to be able to process the unwanted by-products. Design features to mitigate degradation products include filters and chemical or physical traps (eg. cold traps, oil traps). 4. Polymer components can work in tritium systems, but must be replaced regularly. Polymer components performance should be monitored or be regularly tested, and regular replacement of components should be viewed as an expected normal event. A radioactive waste stream must be established to dispose of used polymer components and oil with an approved disposal plan developed based on the facility location and its regulators. Polymers have varying

  19. Blood transfusion in cardiac surgery: Does the choice of anesthesia or type of surgery matter?

    OpenAIRE

    Nešković Vojislava; Milojević Predrag; Unić-Stojanović Dragana; Slavković Zoran

    2013-01-01

    Background/Aim. In spite of the evidence suggesting a significant morbidity associated with blood transfusions, the use of blood and blood products remain high in cardiac surgery. To successfully minimize the need for blood transfusion, a systematic approach is needed. The aim of this study was to investigate the influence of different anesthetic techniques, general vs combine epidural and general anesthesia, as well as different surgery strategies, on-pump vs off-pump, on postoperative...

  20. Sodium bicarbonate and sodium citrate: ergogenic aids?

    Science.gov (United States)

    Requena, Bernardo; Zabala, Mikel; Padial, Paulino; Feriche, Belén

    2005-02-01

    Numerous studies have used exogenous administration of sodium bicarbonate (NaHCO(3)) and sodium citrate (Na-citrate) in an attempt to enhance human performance. After ingestion of NaHCO(3) and Na-citrate, two observations have been made: (a) There was great individual variability in the ergogenic benefit reached, which can be attributed to the level of physical conditioning of the subjects and to their tolerance of the buffer substance; and (b) the subjects who had ingested NaHCO(3) and Na-citrate show higher levels of pH, bicarbonate, and lactate ions concentrations in their exercising blood than do the subjects who had ingested the placebo. A majority of the studies have suggested that the ingestion of both substances provides an ergogenic effect due to the establishment and maintenance of an elevated pH level during exercise. However, the exact mechanism by which the ergogenic effects occur has not been demonstrated conclusively. Sodium bicarbonate and Na-citrate seem to be effective in activities with a sufficient duration to generate a difference in the hydrogen ion gradient, characterized by a very high intensity and involving large muscular groups. However, in activities of equally high intensity, but with longer duration, the results obtained have been conflicting and inconclusive. PMID:15705037

  1. 85,000-GPM, single-stage, single-suction LMFBR intermediate centrifugal pump

    International Nuclear Information System (INIS)

    The mechanical and hydraulic design features of the 85,000-gpm, single-stage, single-suction pump test article, which is designed to circulate liquid-sodium coolant in the intermediate heat-transport system of a Large-Scale Liquid Metal Fast Breeder Reactor (LS-LMFBR), are described. The design and analytical considerations used to satisfy the pump performance and operability requirements are presented. The validation of pump hydraulic performance using a hydraulic scale-model pump is discussed, as is the featute test for the mechanical-shaft seal system

  2. Large scale breeder reactor plant prototype mechanical pump conceptual design study

    Energy Technology Data Exchange (ETDEWEB)

    1976-07-01

    This final report is a complete conceptual design study of a mechanical pump for a large scale breeder reactor plant. The pumps are located in the cold leg side of the loops. This makes the net positive suction head available - NPSHA - low, and is, in fact, a major influencing factor in the design. Where possible, experience gained from the Clinch River Project and the FFTF is used in this study. Experience gained in the design, manufacturer, and testing of pumps in general and sodium pumps in particular is reflected in this report. The report includes estimated cost and time schedule for design, manufacture, and testing. It also includes a recommendation for development needs.

  3. Sodium Ferric Gluconate Injection

    Science.gov (United States)

    ... are also receiving the medication epoetin (Epogen, Procrit). Sodium ferric gluconate injection is in a class of medications called iron replacement products. It works by replenishing iron stores so ...

  4. Fractional excretion of sodium

    Science.gov (United States)

    ... skin) Infection (a slight risk any time the skin is broken) Multiple punctures to locate veins There are no risks with the urine sample. Alternative Names FE sodium; FENa Images Male urinary system References Parikh CR, ...

  5. Chemistry of sodium coolant

    International Nuclear Information System (INIS)

    Properties of impurities of nuclear fuel and its fission products and their behaviour in sodium coolant of the primary circuit of fast reactors are considered. The impurities are classified with account of their properties, behaviour in the circuit and significance

  6. Sodium blood test

    Science.gov (United States)

    ... are not able to conserve water) Too much salt or sodium bicarbonate in the diet Use of certain medicines, including corticosteroids, laxatives, lithium, and medicines such as ibuprofen or naproxen Lower ...

  7. Sodium oxide aerosol filtration

    International Nuclear Information System (INIS)

    In the scope of the sodium aerosol trapping research effort by the CEA/DSN, the retention capacity and yield were measured for very high efficiency fiberglass filters and several types of prefilters (cyclone agglomerator, fabric prefilters, water scrubbers). (author)

  8. Neurocognitive impairment after off-pump and on-pump coronary artery bypass graft surgery – an Iranian experience

    Directory of Open Access Journals (Sweden)

    Mehdi Farhoudi

    2010-11-01

    Full Text Available Mehdi Farhoudi1, Kaveh Mehrvar2, Abbas Afrasiabi3, Rezayat Parvizi3, Ahmad Ali Khalili3, Babak Nasiri3, Khosrow Hashemzadeh3, Kamyar Ghabili41Neurosciences Research Center, Imam Reza Hospital, 2Razi Hospital, 3Cardiovascular Research Center, 4Tuberculosis and Lung Disease Research Center, Tabriz University of Medical Sciences, Tabriz, IranBackground: Coronary artery bypass graft (CABG surgery is one of the most commonly performed surgical procedures worldwide, and it may be accompanied by postoperative neurocognitive impairment. Although this complication has been attributed to the use of cardiopulmonary bypass, it is still a matter of debate whether the switch from on-pump to off-pump technique affects the cognitive function.Objective: The aim of this study was to compare the impact of the on-pump and off-pump techniques on neurocognitive impairment in low-risk CABG surgery groups.Methods: In a descriptive and analytic study, 201 CABG patients with left-ventricular ejection fraction >30%, and without cardiac arrhythmia were enrolled. Before the elective operation, all patients underwent neurological examination and neurocognitive test, Mini-Mental State Examination (MMSE. Two months following the operation, both on- and off-pump, the patients were re-examined by MMSE to detect any neurocognitive impairment.Results: Out of 154 patients included in the study, 95 (61.6% and 59 (38.3% patients were in off-pump and on-pump groups, respectively. Mean age of the patients was 57.17 ± 9.82 years. A 2-month postoperative neurocognitive impairment was detected among 17 patients of on-pump group (28.8% and in 28 cases of off-pump group (29.4% (P = 0.54. The mean postoperative MMSE scores were not comparable between groups (25.01 ± 4.49 in off-pump group versus 23.73 ± 4.88 in on-pump group, P = 0.09.Conclusion: The present study revealed that in low-risk patients undergoing CABG surgery, either the techniques of on-pump or off-pump did not differ

  9. Liquid sodium oxygenmeter

    International Nuclear Information System (INIS)

    The results of test runs of two design varieties of liquid sodium oxygenmeter in sodium loops are described. The accuracy and sensitivity are discussed reached using this instrument within 1 and 10 p.p.m. of oxygen concentration. A change in the used reference system is proposed based on practical experiences and thermochemical calculations. Ceramic electrolyte corrosion is analysed and the possible interpretation of the corrosion effect on the galvanic cell electromotive force is suggested. (author)

  10. Apparatus for Pumping a Fluid

    Science.gov (United States)

    Boeyen, Robert Van; Reeh, Jonathan

    2013-01-01

    A fluid pump has been developed for mechanically pumped fluid loops for spacecraft thermal control. Lynntech's technology utilizes a proprietary electrochemically driven pumping mechanism. Conventional rotodynamic and displacement pumps typically do not meet the stringent power and operational reliability requirements of space applications. Lynntech's developmental pump is a highly efficient solid-state pump with essentially no rotating or moving components (apart from metal bellows).

  11. Natural convection test in secondary sodium circuits of FBTR

    International Nuclear Information System (INIS)

    Fast Breeder Test Reactor (FBTR) is presently operating at a maximum power level of 10 MWt. Several engineering tests have been carried out on the plant and one amongst them is the secondary sodium pumps alone tripped natural convection test at a low power of 180 kW without manipulation of control rods. The purpose of this test is to demonstrate the natural convection capability of the secondary sodium system and the reactor's favourable intrinsic reactivity feedback effects. 7 refs., 5 figs., 1 tab

  12. Investigations of the Navβ1b sodium channel subunit in human ventricle; functional characterization of the H162P Brugada Syndrome mutant

    DEFF Research Database (Denmark)

    Yuan, Lei; Koivumaki, Jussi; Liang, Bo;

    2014-01-01

    Brugada Syndrome (BrS) is a rare inherited disease which can give rise to ventricular arrhythmia and ultimately sudden cardiac death. Numerous loss-of-function mutations in the cardiac sodium channel Nav1.5 have been associated with BrS. However, few mutations in the auxiliary Navβ1-4 subunits have...

  13. Pumping machinery theory and practice

    CERN Document Server

    Badr, Hassan M

    2014-01-01

    Pumping Machinery Theory and Practice comprehensively covers the theoretical foundation and applications of pumping machinery. Key features: Covers characteristics of centrifugal pumps, axial flow pumps and displacement pumpsConsiders pumping machinery performance and operational-type problemsCovers advanced topics in pumping machinery including multiphase flow principles, and two and three-phase flow pumping systemsCovers different methods of flow rate control and relevance to machine efficiency and energy consumptionCovers different methods of flow rate control and relevance to machine effi

  14. Finite Element Model to Study One Dimensional Calcium Dyanmics in Cardiac Myocytes

    Science.gov (United States)

    Pathak, Kunal B.; Adlakha, Neeru

    2015-12-01

    The multi physical process involving calcium ions regulate expansion and contraction of cardiac myocytes. This mechanism of expansion and contraction of cardiac myocytes is responsible for contraction and expansion of heart for pumping of blood into arteries and receiving blood into heart from vein. Thus calcium dynamics in cardiac myocytes is responsible for the activities of the myocytes cells and functioning of the heart. The specific spatiotemporal calcium ion dynamics is required to trigger, sustain and terminate activity of the cell. In this paper an attempt has been done to propose a model to study calcium dynamics in cardiac myocytes for a one-dimensional unsteady state case. The model incorporates the process like diffusion, reaction involving source and excess buffers. Appropriate boundary conditions and initial conditions have been framed. The finite element method has been employed to obtain the solution. The numerical results have been used to study the effect of buffers and source influx on calcium dynamics in cardiac myocytes.

  15. Radionuclide kineventriculographic evaluation of the heart pump function in valvular prosthesis

    International Nuclear Information System (INIS)

    The heart pump function was investigated by the methods of radionuclide kineventriculography, standart opaque ventryculography and echocardiography. The statistical analysis revealed lack of correlation for the ejection fraction, determined by the three methods. The methodological advantages of radionuclide kineventriculography are pointed out for exact and objective evaluation of the ejection fraction of the left cardiac ventricle, as well as some limitations in the application of this index in the clinical assessment of the heart pump function in patients, indicated for valvular prosthesis

  16. Microfluidic reflow pumps.

    Science.gov (United States)

    Haslam, Bryan; Tsai, Long-Fang; Anderson, Ryan R; Kim, Seunghyun; Hu, Weisheng; Nordin, Gregory P

    2015-07-01

    A new microfluidic pump, termed a reflow pump, is designed to operate with a sub-μl sample volume and transport it back and forth between two pneumatically actuated reservoirs through a flow channel typically containing one or more sensor surfaces. The ultimate motivation is to efficiently use the small sample volume in conjunction with convection to maximize analyte flux to the sensor surface(s) in order to minimize sensor response time. In this paper, we focus on the operational properties of the pumps themselves (rather than the sensor surfaces), and demonstrate both two-layer and three-layer polydimethylsiloxane reflow pumps. For the three-layer pump, we examine the effects of reservoir actuation pressure and actuation period, and demonstrate average volumetric flow rates as high as 500 μl/min. We also show that the two-layer design can pump up to 93% of the sample volume during each half period and demonstrate integration of a reflow pump with a single-chip microcantilever array to measure maximum flow rate. PMID:26221199

  17. Pressure charged airlift pump

    Science.gov (United States)

    Campbell, Gene K.

    1983-01-01

    A pumping system is described for pumping fluids, such as water with entrained mud and small rocks, out of underground cavities such as drilled wells, which can effectively remove fluids down to a level very close to the bottom of the cavity and which can operate solely by compressed air pumped down through the cavity. The system utilizes a subassembly having a pair of parallel conduit sections (44, 46) adapted to be connected onto the bottom of a drill string utilized for drilling the cavity, the drill string also having a pair of coaxially extending conduits. The subassembly includes an upper portion which has means for connection onto the drill string and terminates the first conduit of the drill string in a plenum (55). A compressed air-driven pump (62) is suspended from the upper portion. The pump sucks fluids from the bottom of the cavity and discharges them into the second conduit. Compressed air pumped down through the first conduit (46) to the plenum powers the compressed air-driven pump and aerates the fluid in the second conduit to lift it to the earth's surface.

  18. Pediatric cardiac postoperative care

    Directory of Open Access Journals (Sweden)

    Auler Jr. José Otávio Costa

    2002-01-01

    Full Text Available The Heart Institute of the University of São Paulo, Medical School is a referral center for the treatment of congenital heart diseases of neonates and infants. In the recent years, the excellent surgical results obtained in our institution may be in part due to modern anesthetic care and to postoperative care based on well-structured protocols. The purpose of this article is to review unique aspects of neonate cardiovascular physiology, the impact of extracorporeal circulation on postoperative evolution, and the prescription for pharmacological support of acute cardiac dysfunction based on our cardiac unit protocols. The main causes of low cardiac output after surgical correction of heart congenital disease are reviewed, and methods of treatment and support are proposed as derived from the relevant literature and our protocols.

  19. Thermal energy storage using thermo-chemical heat pump

    International Nuclear Information System (INIS)

    Highlights: ► Understanding of the performance of thermo chemical heat pump. ► Tool for storing thermal energy. ► Parameters that affect the amount of thermal stored energy. ► Lithium chloride has better effect on storing thermal energy. - Abstract: A theoretical study was performed to investigate the potential of storing thermal energy using a heat pump which is a thermo-chemical storage system consisting of water as sorbet, and sodium chloride as the sorbent. The effect of different parameters namely; the amount of vaporized water from the evaporator, the system initial temperature and the type of salt on the increase in temperature of the salt was investigated and hence on the performance of the thermo chemical heat pump. It was found that the performance of the heat pump improves with the initial system temperature, with the amount of water vaporized and with the water remaining in the system. Finally it was also found that lithium chloride salt has higher effect on the performance of the heat pump that of sodium chloride.

  20. Effect of parameter variations on the hemodynamic response under rotary blood pump assistance.

    Science.gov (United States)

    Lim, Einly; Dokos, Socrates; Salamonsen, Robert F; Rosenfeldt, Franklin L; Ayre, Peter J; Lovell, Nigel H

    2012-05-01

    Numerical models, able to simulate the response of the human cardiovascular system (CVS) in the presence of an implantable rotary blood pump (IRBP), have been widely used as a predictive tool to investigate the interaction between the CVS and the IRBP under various operating conditions. The present study investigates the effect of alterations in the model parameter values, that is, cardiac contractility, systemic vascular resistance, and total blood volume on the efficiency of rotary pump assistance, using an optimized dynamic heart-pump interaction model previously developed in our laboratory based on animal experimental measurements obtained from five canines. The effect of mean pump speed and the circulatory perturbations on left and right ventricular pressure volume loops, mean aortic pressure, mean cardiac output, pump assistance ratio, and pump flow pulsatility from both the greyhound experiments and model simulations are demonstrated. Furthermore, the applicability of some of the previously proposed control parameters, that is, pulsatility index (PI), gradient of PI with respect to pump speed, pump differential pressure, and aortic pressure are discussed based on our observations from experimental and simulation results. It was found that previously proposed control strategies were not able to perform well under highly varying circulatory conditions. Among these, control algorithms which rely on the left ventricular filling pressure appear to be the most robust as they emulate the Frank-Starling mechanism of the heart. PMID:22489771

  1. Giant Cardiac Cavernous Hemangioma.

    Science.gov (United States)

    Unger, Eric; Costic, Joseph; Laub, Glenn

    2015-07-01

    We report the case of an asymptomatic giant cardiac cavernous hemangioma in a 71-year-old man. The intracardiac mass was discovered incidentally during surveillance for his prostate cancer; however, the patient initially declined intervention. On presentation to our institution 7 years later, the lesion had enlarged significantly, and the patient consented to excision. At surgery, an 8 × 6.5 × 4.8 cm intracardiac mass located on the inferior heart border was excised with an intact capsule through a median sternotomy approach. The patient had an uneventful postoperative course. We discuss the diagnostic workup, treatment, and characteristics of this rare cardiac tumor. PMID:26140782

  2. Design validation of the 4S high temperature electromagnetic pump by one pole segment test equipment

    International Nuclear Information System (INIS)

    Toshiba has developed the Super-Safe, Small and Simple sodium-cooled reactor, named as 4S. 4S has the features that the passive safety design, no on-site refuelling for 30 years, the low maintenance. 4S adopts a high temperature sodium immersed electromagnetic pump (EM pump) as the primary pump. The coil diameter of 4S EM pump is one and a half times as larger than that of 160 m3/min EM pump which Toshiba has already developed. To confirm the manufacturability of the large diameter coil with the high temperature insulation and the large size stator, the one pole segment test equipment, which has one-sixth height and same size radius of 4S EM pump, was manufactured. In this paper, the test results of the one pole segment test equipment are reported. It was confirmed the structural integrity of EM pump caused by the electromagnetic oscillation by the energization of a coil. By the heat cycle test, it was able to confirm the structural integrity during the operation of 4S EM pump and the insulation performance in the high-temperature environment. These test results would be reflected the design and the manufacture of 4S EM pump. (author)

  3. Radiography in cardiology [cardiac disorders, cardiac insufficiency

    International Nuclear Information System (INIS)

    The diagnostic procedure in cardiology nearly always requires an X-ray examination of the thorax. This examination is very informative when it is correctly performed and interpreted. The radiographs need to be read precisely and comprehensively: this includes the evaluation of the silhouette of the heart (size, form and position) as well as the examination of extra-cardiac thoracic structures allowing among other things to search for signs of cardiac insufficiency. The conclusion of the X-ray examination can be drawn after having brought together information concerning the case history, the clinical examination and the study of the radiographs. The radiologist finds himself in one of three situations: (1) the information provided by the X-ray pictures is characteristic of a disease and permits a diagnosis, (2) the X-ray pictures indicate a group of hypotheses; further complementary tests could be useful and (3) the X-ray pictures provide ambiguous even contradictory information; it is necessary to complete the radiological examination by other techniques such as an ultrasonographic study of the heart

  4. Hydrogen generation systems utilizing sodium silicide and sodium silica gel materials

    Science.gov (United States)

    Wallace, Andrew P.; Melack, John M.; Lefenfeld, Michael

    2015-07-14

    Systems, devices, and methods combine reactant materials and aqueous solutions to generate hydrogen. The reactant materials can sodium silicide or sodium silica gel. The hydrogen generation devices are used in fuels cells and other industrial applications. One system combines cooling, pumping, water storage, and other devices to sense and control reactions between reactant materials and aqueous solutions to generate hydrogen. Multiple inlets of varied placement geometries deliver aqueous solution to the reaction. The reactant materials and aqueous solution are churned to control the state of the reaction. The aqueous solution can be recycled and returned to the reaction. One system operates over a range of temperatures and pressures and includes a hydrogen separator, a heat removal mechanism, and state of reaction control devices. The systems, devices, and methods of generating hydrogen provide thermally stable solids, near-instant reaction with the aqueous solutions, and a non-toxic liquid by-product.

  5. Hydrogen generation systems and methods utilizing sodium silicide and sodium silica gel materials

    Science.gov (United States)

    Wallace, Andrew P.; Melack, John M.; Lefenfeld, Michael

    2015-08-11

    Systems, devices, and methods combine thermally stable reactant materials and aqueous solutions to generate hydrogen and a non-toxic liquid by-product. The reactant materials can sodium silicide or sodium silica gel. The hydrogen generation devices are used in fuels cells and other industrial applications. One system combines cooling, pumping, water storage, and other devices to sense and control reactions between reactant materials and aqueous solutions to generate hydrogen. Springs and other pressurization mechanisms pressurize and deliver an aqueous solution to the reaction. A check valve and other pressure regulation mechanisms regulate the pressure of the aqueous solution delivered to the reactant fuel material in the reactor based upon characteristics of the pressurization mechanisms and can regulate the pressure of the delivered aqueous solution as a steady decay associated with the pressurization force. The pressure regulation mechanism can also prevent hydrogen gas from deflecting the pressure regulation mechanism.

  6. Serum myoglobin after cardiac catheterisation.

    OpenAIRE

    McComb, J. M.; McMaster, E A

    1982-01-01

    Study of 80 consecutive patients undergoing elective diagnostic cardiac catheterisation showed that after the procedure 25 (31%) developed myoglobinaemia. This was attributed to complications of the catheterisation in two. The remaining 23 had received premedication by intramuscular injection. In patients without intramuscular injections myoglobinaemia did not occur after uncomplicated cardiac catheterisation. The study did not support the proposition that cardiac catheterisation results in m...

  7. Experience in the maintenance of sodium systems of fast breeder test reactor

    International Nuclear Information System (INIS)

    The fast breeder test reactor (FBTR) is a loop type sodium cooled fast reactor located at Kalpakkam in India and that has been operating for 25 years. The reactor has been operated up to a power level of 18.6 MWt with a sodium outlet temperature of 482 C. degrees. Several modifications were carried out in the sodium systems to improve the plant performance. During the course of operation of the reactor, a number of sodium laden components like pumps, valves, cold traps, rupture disks, level probes, shielding plugs, control rod drive mechanisms, experimental assemblies, piping... were removed for various maintenance, modification and replacement jobs which has given the operators a valuable experience in handling large scale sodium systems. This paper details the special procedures followed during the handling of active and inactive sodium laden components

  8. Current Pharmacological Advances in the Treatment of Cardiac Arrest

    Directory of Open Access Journals (Sweden)

    Andry Papastylianou

    2012-01-01

    Full Text Available Cardiac arrest is defined as the sudden cessation of spontaneous ventilation and circulation. Within 15 seconds of cardiac arrest, the patient loses consciousness, electroencephalogram becomes flat after 30 seconds, pupils dilate fully after 60 seconds, and cerebral damage takes place within 90–300 seconds. It is essential to act immediately as irreversible damage can occur in a short time. Cardiopulmonary resuscitation (CPR is an attempt to restore spontaneous circulation through a broad range of interventions which are early defibrillation, high-quality and uninterrupted chest compressions, advanced airway interventions, and pharmacological interventions. Drugs should be considered only after initial shocks have been delivered (when indicated and chest compressions and ventilation have been started. During cardiopulmonary resuscitation, no specific drug therapy has been shown to improve survival to hospital discharge after cardiac arrest, and only few drugs have a proven benefit for short-term survival. This paper reviews current pharmacological treatment of cardiac arrest. There are three groups of drugs relevant to the management of cardiac arrest: vasopressors, antiarrhythmics, and other drugs such as sodium bicarbonate, calcium, magnesium, atropine, fibrinolytic drugs, and corticosteroids.

  9. Pumping and Breastmilk Storage

    Science.gov (United States)

    ... refrigerate or freeze your breastmilk also qualify as tax-deductible breastfeeding gear. After each pumping Label the ... cause some of the milk's valuable parts to break down. Refrigerate or chill milk right after it ...

  10. Keeping Hearts Pumping

    Science.gov (United States)

    2002-01-01

    A collaboration between NASA, Dr. Michael DeBakey, Dr. George Noon, and MicroMed Technology, Inc., resulted in a life-saving heart pump for patients awaiting heart transplants. The MicroMed DeBakey VAD functions as a "bridge to heart transplant" by pumping blood throughout the body to keep critically ill patients alive until a donor heart is available. Weighing less than 4 ounces and measuring 1 inch by 3 inches, the pump is approximately one-tenth the size of other currently marketed pulsatile VADs. This makes it less invasive and ideal for smaller adults and children. Because of the pump's small size, less than 5 percent of the patients implanted developed device-related infections. It can operate up to 8 hours on batteries, giving patients the mobility to do normal, everyday activities.The MicroMed DeBakey VAD is a registered trademark of MicroMed Technology, Inc.

  11. Nuclear-pumped lasers

    CERN Document Server

    Prelas, Mark

    2016-01-01

    This book focuses on Nuclear-Pumped Laser (NPL) technology and provides the reader with a fundamental understanding of NPLs, a review of research in the field, and exploration of large scale NPL system design and applications. Early chapters look at the fundamental properties of lasers, nuclear-pumping and nuclear reactions that may be used as drivers for nuclear-pumped lasers. The book goes on to explore the efficient transport of energy from the ionizing radiation to the laser medium and then the operational characteristics of existing nuclear-pumped lasers. Models based on Mathematica, explanations and a tutorial all assist the reader’s understanding of this technology. Later chapters consider the integration of the various systems involved in NPLs and the ways in which they can be used, including beyond the military agenda. As readers will discover, there are significant humanitarian applications for high energy/power lasers, such as deflecting asteroids, space propulsion, power transmission and mining....

  12. High Voltage Charge Pump

    KAUST Repository

    Emira, Ahmed A.

    2014-10-09

    Various embodiments of a high voltage charge pump are described. One embodiment is a charge pump circuit that comprises a plurality of switching stages each including a clock input, a clock input inverse, a clock output, and a clock output inverse. The circuit further comprises a plurality of pumping capacitors, wherein one or more pumping capacitors are coupled to a corresponding switching stage. The circuit also comprises a maximum selection circuit coupled to a last switching stage among the plurality of switching stages, the maximum selection circuit configured to filter noise on the output clock and the output clock inverse of the last switching stage, the maximum selection circuit further configured to generate a DC output voltage based on the output clock and the output clock inverse of the last switching stage.

  13. Advanced heat pump

    Science.gov (United States)

    Ashley, Joseph L.; Matthews, John D.

    1989-09-01

    This patent application discloses a heat pump which includes a first packed bed of liquid desiccant for removing moisture from outside air in the heating mode of operation, and a pump for transferring the moisture laden desiccant to a second packed bed which humidifies condenser heated inside air by adding water vapor to the air. The first packed bed, by removing moisture from the outside air before it passes through the heat pump's evaporator coils, prevents frost from forming on the coils. In the cooling mode of operation the second packed bed of liquid desiccant removes water vapor from the air inside of the building. The moisture laden desiccant is then transferred to the first packed bed by a second pump where condenser heat transfers the moisture from the desiccant to outside air.

  14. Analyses of annular linear induction pump characteristics using a time-harmonic finite difference analysis

    International Nuclear Information System (INIS)

    The pumping of coolant in a liquid metal fast reactor may be performed with an annular linear induction Electro-Magnetic (EM) pump. Linear induction pumps use a traveling magnetic field wave created by poly-phase currents, and the induced currents and their associated magnetic field generate a Lorentz force, whose effect can be the pumping of the liquid metal. The flow behaviors in the pump are very complex, including a time-varying Lorentz force and pressure pulsation, because an induction EM pump has time-varying magnetic fields and the induced convective currents that originate from the flow of the liquid metal. These phenomena lead to an instability problem in the pump arising from the changes of the generated Lorentz forces along the pump's geometry. Therefore, a Magneto-Hydro-Dynamics (MHD) analysis is required for the design and operation of a linear induction EM pump. We have developed a time-harmonic 2-dimensional axisymmetry MHD analysis method based on the Maxwell equations. This paper describes the analysis and numerical method for obtaining solutions for some MHD parameters in an induction EM pump. Experimental test results obtained from an induction EM pump of CLIP-150 at the STC 'Sintez,' D.V. Efremov Institute of Electro-physical Apparatus in St. Petersburg were used to validate the method. In addition, we investigated some characteristics of a linear induction EM pump, such as the effect of the convective current and the Double Supply Frequency (DSF) pressure pulsation. This simple model overestimated the convective eddy current generated from the sodium flow in the pump channel; however, it had a similar tendency for the measured data of the pump performance through a comparison with the experimental data. Considering its simplicity, it could be a base model for designing an EM pump and for evaluating the MHD flow in an EM pump

  15. Cardiac adaptations of bullfrog tadpoles in response to chytrid infection.

    Science.gov (United States)

    Salla, Raquel Fernanda; Gamero, Fernando Urban; Ribeiro, Larissa Rodrigues; Rizzi, Gisele Miglioranza; Medico, Samuel Espinosa Dal; Rissoli, Rafael Zanelli; Vieira, Conrado Augusto; Silva-Zacarin, Elaine Cristina Mathias; Leite, Domingos Silva; Abdalla, Fábio Camargo; Toledo, Luis Felipe; Costa, Monica Jones

    2015-08-01

    The chytrid fungus Batrachochytrium dendrobatidis (Bd) can result in heart failure in Bd-susceptible species. Since Bd infection generally does not cause mortality in North American bullfrogs, the aim of this work was to verify whether this species presents any cardiac adaptation that could improve the tolerance to the fungus. Thus, we analyzed tadpoles' activity level, relative ventricular mass, ventricle morphology, in loco heart frequency, and in vitro cardiac function. The results indicate that infected animals present an increase in both ventricular relative mass and in myofibrils' incidence, which accompanied the increase in myocytes' diameter. Such morphological alterations enabled an increase in the in vitro twitch force that, in vivo, would result in elevation of the cardiac stroke volume. This response requires much less energy expenditure than an elevation in heart frequency, but still enables the heart to pump a higher volume of blood per minute (i.e., an increase in cardiac output). As a consequence, the energy saved in the regulation of the cardiac function of Bd-infected tadpoles can be employed in other homeostatic adjustments to avoid the lethal effect of the fungus. Whether other species present this ability, and to what extent, remains uncertain, but such possible interspecific variability might explain different mortality rates among different species of Bd-infected amphibians. PMID:26055358

  16. Lunar Base Heat Pump

    Science.gov (United States)

    Walker, D.; Fischbach, D.; Tetreault, R.

    1996-01-01

    The objective of this project was to investigate the feasibility of constructing a heat pump suitable for use as a heat rejection device in applications such as a lunar base. In this situation, direct heat rejection through the use of radiators is not possible at a temperature suitable for lde support systems. Initial analysis of a heat pump of this type called for a temperature lift of approximately 378 deg. K, which is considerably higher than is commonly called for in HVAC and refrigeration applications where heat pumps are most often employed. Also because of the variation of the rejection temperature (from 100 to 381 deg. K), extreme flexibility in the configuration and operation of the heat pump is required. A three-stage compression cycle using a refrigerant such as CFC-11 or HCFC-123 was formulated with operation possible with one, two or three stages of compression. Also, to meet the redundancy requirements, compression was divided up over multiple compressors in each stage. A control scheme was devised that allowed these multiple compressors to be operated as required so that the heat pump could perform with variable heat loads and rejection conditions. A prototype heat pump was designed and constructed to investigate the key elements of the high-lift heat pump concept. Control software was written and implemented in the prototype to allow fully automatic operation. The heat pump was capable of operation over a wide range of rejection temperatures and cooling loads, while maintaining cooling water temperature well within the required specification of 40 deg. C +/- 1.7 deg. C. This performance was verified through testing.

  17. Tokamak pump limiters

    International Nuclear Information System (INIS)

    Recent experiments with a scoop limiter without active internal pumping have been carried out in the PDX tokamak with up to 6MW of auxiliary neutral beam heating. Experiments have also been done with a rotating head pump limiter in the PLT tokamak in conjunction with RF plasma heating. Extensive experiments have been done in the ISX-B tokamak and first experiments have been completed with the ALT-I limiter in TEXTOR. The pump limiter modules in these latter two machines have internal getter pumping. Experiments in ISX-B are with ohmic and auxiliary neutral beam heating. The results in ISX-B and TEXTOR show that active density control and particle removal is achieved with pump limiters. In ISX-B, the boundary layer (or scape-off layer) plasma partially screens the core plasma from gas injection. In both ISX-B and TEXTOR, the pressure internal to the module scales linearly with plasma density but in ISX-B, with neutral beam injection, a nonlinear increase is observed at the highest densities studied. Plasma plugging is the suspected cause. Results from PDX suggest that a region may exist in which core plasma energy confinement improves using a pump limiter during neutral beam injection. Asymmetric radial profiles and an increased edge electron temperature are observed in discharges with improved confinement. The injection of small amounts of neon into ISX-B has more clearly shown an improved electron core energy confinement during neutral beam injection. While carried out with a regular limiter, this Z-mode of operation is ideal for use with pump limiters and should be a way to achieve energy confinement times similar to values for H-mode tokamak plasmas. The implication of all these results for the design of a reactor pump limiter is described

  18. Portable photovoltaic irrigation pumps

    Energy Technology Data Exchange (ETDEWEB)

    Furber, J.D.

    1980-07-01

    Experiences in developing a solar-powered irrigation pump to meet the needs of poor farmers in developing nations are summarized. The design which evolved is small and portable, employing a high-efficiency electric pump, powered by photovoltaic panels. Particular emphasis is placed on how the system works, and on early field problems experienced with the first prototypes. The resolution of these problems and the performance of actual systems in various countries is presented and user responses are noted.

  19. Rotary blood pump

    Science.gov (United States)

    Benkowski, Robert J. (Inventor); Kiris, Cetin (Inventor); Kwak, Dochan (Inventor); Rosenbaum, Bernard J. (Inventor); Bacak, James W. (Inventor); DeBakey, Michael E. (Inventor)

    1999-01-01

    A blood pump that comprises a pump housing having a blood flow path therethrough, a blood inlet, and a blood outlet; a stator mounted to the pump housing, the stator having a stator field winding for producing a stator magnetic field; a flow straightener located within the pump housing, and comprising a flow straightener hub and at least one flow straightener blade attached to the flow straightener hub; a rotor mounted within the pump housing for rotation in response to the stator magnetic field, the rotor comprising an inducer and an impeller; the inducer being located downstream of the flow straightener, and comprising an inducer hub and at least one inducer blade attached to the inducer hub; the impeller being located downstream of the inducer, and comprising an impeller hub and at least one impeller blade attached to the impeller hub; and preferably also comprising a diffuser downstream of the impeller, the diffuser comprising a diffuser hub and at least one diffuser blade. Blood flow stagnation and clot formation within the pump are minimized by, among other things, providing the inducer hub with a diameter greater than the diameter of the flow straightener hub; by optimizing the axial spacing between the flow straightener hub and the inducer hub, and between the impeller hub and the diffuser hub; by optimizing the inlet angle of the diffuser blades; and by providing fillets or curved transitions between the upstream end of the inducer hub and the shaft mounted therein, and between the impeller hub and the shaft mounted therein.

  20. Hepato-cardiac disorders

    Institute of Scientific and Technical Information of China (English)

    Yasser; Mahrous; Fouad; Reem; Yehia

    2014-01-01

    Understanding the mutual relationship between the liver and the heart is important for both hepatologists and cardiologists. Hepato-cardiac diseases can be classified into heart diseases affecting the liver, liver diseases affecting the heart, and conditions affecting the heart and the liver at the same time. Differential diagnoses of liver injury are extremely important in a cardiologist’s clinical practice calling for collaboration between cardiologists and hepatologists due to the many other diseases that can affect the liver and mimic haemodynamic injury. Acute and chronic heart failure may lead to acute ischemic hepatitis or chronic congestive hepatopathy. Treatment in these cases should be directed to the primary heart disease. In patients with advanced liver disease, cirrhotic cardiomyopathy may develop including hemodynamic changes, diastolic and systolic dysfunctions, reduced cardiac performance and electrophysiological abnormalities. Cardiac evaluation is important for patients with liver diseases especially before and after liver transplantation. Liver transplantation may lead to the improvement of all cardiac changes and the reversal of cirrhotic cardiomyopathy. There are systemic diseases that may affect both the liver and the heart concomitantly including congenital, metabolic and inflammatory diseases as well as alcoholism. This review highlights these hepatocardiac diseases

  1. Primary cardiac tumors

    International Nuclear Information System (INIS)

    Cardiac tumors happen to be among the less known pathologies without clear treatment standards. Even one decade ago most of the cardiac tumor diagnosis were made post mortem, and only reports of isolated cases could be found in the literature, showing the lack of interest in the investigation of these pathologies by cardiology and cardiovascular surgery specialists. With the development of echocardiography and of cardiovascular surgery, more cases of primary and metastatic cardiac tumors have been diagnosed. Many cases have been treated by palliative or curative surgical interventions, thus increasing the reports in the world literature and the experience in this field, and pointing out the real incidence of these pathologies, not being as bizarre as it had been considered. a revision of the literature will be made, in which the frequency and the suggested interventions will be reported, as well as the cases of cardiac pathology in two cardiovascular centers of the country known by the author. The echocardiographic, pathologic and histological characteristics of the representative cases will be presented, without a greater evidence level, due to the problem's incidence and the few cases reported by these centers

  2. Cardiac MRI tagging

    International Nuclear Information System (INIS)

    Cardiac MRI tagging is an original technique based upon the perturbation of the magnetization of determined regions of the myocardium (tags). The motion of the tags accurately reflects the deformation of the underlying tissue. Data analysis requires special techniques to reconstruct the 3D motion of the heart, and to evaluate the myocardial strain, locally and throughout the whole heart. (authors)

  3. Automatic Implantable Cardiac Defibrillator

    Medline Plus

    Full Text Available ... Over the next hour you'll see the implantation of an automated implantable cardiac defibrillator. The surgery ... evening we're going to be discussing the implantation of a defibrillator. It’s a battery-powered implantable ...

  4. Cardiac effects of vasopressin.

    Science.gov (United States)

    Pelletier, Jean-Sébastien; Dicken, Bryan; Bigam, David; Cheung, Po-Yin

    2014-07-01

    Vasopressin is an essential hormone involved in the maintenance of cardiovascular homeostasis. It has been in use therapeutically for many decades, with an emphasis on its vasoconstrictive and antidiuretic properties. However, this hormone has a ubiquitous influence and has specific effects on the heart. Although difficult to separate from its powerful vascular effects in the clinical setting, a better understanding of vasopressin's direct cardiac effects could lead to its more effective clinical use for a variety of shock states by maximizing its therapeutic benefit. The cardiac-specific effects of vasopressin are complex and require further elucidation. Complicating our understanding include the various receptors and secondary messengers involved in vasopressin's effects, which may lead to various results based on differing doses and varying environmental conditions. Thus, there have been contradictory reports on vasopressin's action on the coronary vasculature and on its effect on inotropy. However, beneficial results have been found and warrant further study to expand the potential therapeutic role of vasopressin. This review outlines the effect of vasopressin on the coronary vasculature, cardiac contractility, and on hypertrophy and cardioprotection. These cardiac-specific effects of vasopressin represent an interesting area for further study for potentially important therapeutic benefits. PMID:24621650

  5. Cardiac pacemaker power sources

    International Nuclear Information System (INIS)

    A review of chemical and radioisotope batteries used in cardiac pacemakers is presented. The battery systems are examined in terms of longevity, reliability, cost, size and shape, energy density, weight, internal resistance versus time, end-of-life voltage, chemical compatibility, and potential failure mechanisms

  6. Pump trials for charged liquids

    International Nuclear Information System (INIS)

    The pumps intended for the circulation of charged and radioactive liquids have particular qualities. The choice of such a pump has called for endurance tests with various types of equipment: a Goodyear volumetric screw pumps, and RICHIER, Klein and SCHABAVER centrifugal pumps. The latter, fitted with a special oakum, gave the best results. (authors)

  7. Io's sodium cloud

    Science.gov (United States)

    Goldberg, B. A.; Garneau, G. W.; Lavoie, S. K.

    1984-01-01

    The first two-dimensional images of the source region of Io's neutral sodium cloud have been acquired by ground-based observation. Observed asymmetries in its spatial brightness distribution provide new evidence that the cloud is supplied by sodium that is ejected nonisotropically from Io or its atmosphere. Complementary, high-time-resolution, calibrated image sequences that give the first comprehensive picture of the variations of the fainter regions of the cloud extending more than 100,000 kilometers from Io were also obtained. These data demonstrate that the cloud exhibits a persistent systematic behavior coupled with Io's orbital position, a distinct 'east-west orbital asymmetry', a variety of spatial morphologies, and true temporal changes. The geometric stability of the sodium source is also indicated. Isolation of the cloud's temporal changes constitutes an important milestone toward its utilization as a long-term probe of Io and the inner Jovian magnetosphere.

  8. [Cardiac amyloidosis. General review].

    Science.gov (United States)

    Laraki, R

    1994-04-01

    Cardiac amyloidosis, most often of AL type, is a non-exceptional disease as it represents 5 to 10% of non-ischemic cardiomyopathies. It realizes typically a restrictive cardiomyopathy. Nevertheless the wide diversity of possible presentation makes it a "big shammer" which must be evoked in front of every unexplained cardiopathy after the age of forty. If some associated manifestations can rapidly suggest the diagnosis, as a peripheric neuropathy especially a carpal tunnel syndrome or palpebral ecchymosis, cardiac involvement can also evolve in an apparently isolated way. The most suggestive paraclinic elements for the diagnosis are, in one hand, the increased myocardial echogenicity with a "granular sparkling" appearance seen throughout all walls of the left ventricle and, in the other hand, the association of a thickened left ventricle and a low voltage (electrocardiogram could also show pseudo-infarct Q waves). In front of such aspects, the proof of amyloidosis is brought by an extra-cardiac biopsy or by scintigraphy with labelled serum amyloid P component, so that the indications of endomyocardial biopsy are very limited today. The identification of the amyloid nature of a cardiopathy has an direct therapeutic implication: it contra-indicates the use of digitalis, calcium channel blockers and beta-blockers. The treatment of AL amyloidosis (chemotherapy with alkylant agents) remains very unsatisfactory especially in the cardiac involvement which is the most frequent cause of death (in AL amyloidosis). Last, cardiac amyloidosis is a bad indication for transplantation which results are burden by rapid progression of deposits especially in the gastro-intestinal tract and the nervous system. PMID:8059146

  9. Cardiac surgery outcomes.

    Science.gov (United States)

    Halpin, Linda S; Barnett, Scott D; Beachy, Jim

    2003-01-01

    Accrediting organizations and payers are demanding valid and reliable data that demonstrate the value of services. Federal agencies, healthcare industry groups, and healthcare watchdog groups are increasing the demand for public access to outcomes data. A new and growing outcomes dynamic is the information requested by prospective patients in an increasingly consumer-oriented business. Patients demand outcomes, and resources are developing to meet these demands. Physicians are increasingly confronted with requests for information about their mortality and morbidity rates, malpractice suits, and disciplinary actions received. For example, in Virginia, prospective patients have access to data provided by the nonprofit group Virginia Health Information. After numerous resolutions by the Virginia Senate since 1999, the prospective Virginia medical consumer now has access to several annual publications: Virginia Hospitals: A Consumer's Guide, 1999 Annual Report and Strategic Plan Update, and the 1999 Industry Report: Virginia Hospitals and Nursing Facilities. Consumers have access to cardiac outcomes data stratified by hospital, gender, and cardiac service line (cardiac surgery, noninvasive cardiology, and invasive cardiology). This is particularly relevant to IHI because Virginia Health Information specifically targets cardiac care. IHI has a sizable investment in cardiovascular outcomes and has found outcomes measurement and research are key to providing quality care. IHI's goal is to move from an outcomes management model to a disease management model. The hope is to incorporate all aspects of the patient's continuum of care, from preoperative and diagnostic services through cardiac interventions to postoperative rehabilitation. Furthermore, every step along the way will be supported with functional status and quality of life assessments. Although these goals are ambitious and expensive, the return on investment is high. PMID:14618772

  10. Sodium fire tests for investigating the sodium leak in Monju

    International Nuclear Information System (INIS)

    As a part of the work for investigating the sodium leak accident which occurred in Monju on December 8, 1995, three tests, (1) sodium leak test, (2) sodium fire test-I, and (3) sodium fire test-II, were carried out at OEC/PNC. Main objectives of these tests are to confirm leak and burning behavior of sodium from the damaged thermometer, and effects of the sodium fire on integrity of the surrounding structure, etc. The main conclusions obtained from the tests are shown as below. 1) Average sodium leak rate obtained from the sodium leak test was about 50 g/sec. This was equivalent to the value estimated from level change in the sodium overflow tank in the Monju accident. 2) Observation from video cameras in the sodium fire tests revealed that in early stages of sodium leak, sodium dropped down out of the flexible tube of thermometer in drips. This dripping and burning were expanded in range as sodium splashed on the duct. 3) Though, in the sodium fire test-I, there was a decrease of about 1 mm at a thickness of the burning pan in the vicinity in just under in the leak point, there were completely no crack and failure. In the meantime, in the sodium fire test-II the six open holes were found in the floor liner. By this liner failure, the reaction between sodium and concrete might take place. At present, while the detailed evaluation on the sodium fire test-II has been mainly carried out, the investigation for clarifying the cause of the liner failure has been also carried out. (author)

  11. Design of a Mechanical NaK Pump for Fission Space Power

    Science.gov (United States)

    Mireles, Omar R.; Bradley, David E.; Godfroy, Thomas

    2011-01-01

    Alkali liquid metal cooled fission reactor concepts are under development for spaceflight power requirements. One such concept utilizes a sodium-potassium eutectic (NaK) as the primary loop working fluid, which has specific pumping requirements. Traditionally, electromagnetic linear induction pumps have been used to provide the required flow and pressure head conditions for NaK systems but they can be limited in performance, efficiency, and number of available vendors. The objective of the project was to develop a mechanical NaK centrifugal pump that takes advantages of technology advances not available in previous liquid metal mechanical pump designs. This paper details the design, build, and performance test of a mechanical NaK pump developed at NASA Marshall Space Flight Center. The pump was designed to meet reactor cooling requirements using commercially available components modified for high temperature NaK service.

  12. Thermally Actuated Hydraulic Pumps

    Science.gov (United States)

    Jones, Jack; Ross, Ronald; Chao, Yi

    2008-01-01

    Thermally actuated hydraulic pumps have been proposed for diverse applications in which direct electrical or mechanical actuation is undesirable and the relative slowness of thermal actuation can be tolerated. The proposed pumps would not contain any sliding (wearing) parts in their compressors and, hence, could have long operational lifetimes. The basic principle of a pump according to the proposal is to utilize the thermal expansion and contraction of a wax or other phase-change material in contact with a hydraulic fluid in a rigid chamber. Heating the chamber and its contents from below to above the melting temperature of the phase-change material would cause the material to expand significantly, thus causing a substantial increase in hydraulic pressure and/or a substantial displacement of hydraulic fluid out of the chamber. Similarly, cooling the chamber and its contents from above to below the melting temperature of the phase-change material would cause the material to contract significantly, thus causing a substantial decrease in hydraulic pressure and/or a substantial displacement of hydraulic fluid into the chamber. The displacement of the hydraulic fluid could be used to drive a piston. The figure illustrates a simple example of a hydraulic jack driven by a thermally actuated hydraulic pump. The pump chamber would be a cylinder containing encapsulated wax pellets and containing radial fins to facilitate transfer of heat to and from the wax. The plastic encapsulation would serve as an oil/wax barrier and the remaining interior space could be filled with hydraulic oil. A filter would retain the encapsulated wax particles in the pump chamber while allowing the hydraulic oil to flow into and out of the chamber. In one important class of potential applications, thermally actuated hydraulic pumps, exploiting vertical ocean temperature gradients for heating and cooling as needed, would be used to vary hydraulic pressures to control buoyancy in undersea research

  13. Too Much Sodium

    Centers for Disease Control (CDC) Podcasts

    2012-02-07

    This podcast is based on the February 2012 CDC Vital Signs report. Ninety percent of Americans age two and older eat too much sodium which can increase your risk for high blood pressure and often leads to heart disease and stroke, two leading causes of death in the US. Learn several small steps you can take to reduce the amount of sodium in your diet.  Created: 2/7/2012 by Centers for Disease Control and Prevention (CDC).   Date Released: 2/7/2012.

  14. Risk factors and the effect of cardiac resynchronization therapy on cardiac and non-cardiac mortality in MADIT-CRT

    DEFF Research Database (Denmark)

    Perkiomaki, Juha S; Ruwald, Anne-Christine; Kutyifa, Valentina;

    2015-01-01

    causes, 108 (63.9%) deemed cardiac, and 61 (36.1%) non-cardiac. In multivariate analysis, increased baseline creatinine was significantly associated with both cardiac and non-cardiac deaths [hazard ratio (HR) 2.97, P ...AIMS: To understand modes of death and factors associated with the risk for cardiac and non-cardiac deaths in patients with cardiac resynchronization therapy with implantable cardioverter-defibrillator (CRT-D) vs. implantable cardioverter-defibrillator (ICD) therapy, which may help clarify...

  15. Severe hyperkalaemia and ketoacidosis during routine treatment with an insulin pump.

    OpenAIRE

    Knight, G; Jennings, A M; Boulton, A J; Tomlinson, S; Ward, J.D.

    1985-01-01

    During a feasibility study of the use of insulin pumps to treat diabetes ketoacidosis occurred at a rate of 0.14 episodes/patient/year in the first year but was lower in subsequent years. A case of cardiac arrest secondary to hyperkalaemia during ketoacidosis occurred in a patient treated with a pump. The mean (SD) serum potassium concentration on presentation to hospital with ketoacidosis was significantly higher in patients treated with a pump (5.7 (1.1) mmol(mEq)/l) than those treated with...

  16. The various sodium purification techniques

    International Nuclear Information System (INIS)

    In the framework of sodium waste treatment, the sodium purification phase plays an essential role in the chain of operations leading to the transformation of the active sodium, considered as waste, into a stable sodium salt. The sodium purification processes as regards to the hydrogen, oxygen and caesium, that are aimed at facilitating the subsequent treatment of sodium, are therefore mastered operations. Regarding the operations associated with the reduction of the tritium activity, the methods are in the process of being qualified, or to be qualified

  17. Status of sodium boiling noise detection programme at reactor research centre, India

    International Nuclear Information System (INIS)

    Acoustic detection of sodium boiling is a promising technique to monitor subassembly fault in a last reactor. This paper summarises the programme for developing this detection system and describes the design of a high temperature transducer for boiling detection. It is appreciated that the background noise from primary pumps can interfere with this detection. Noise measurements were therefore carried out during water testing of the primary pump of the Fast Breeder Test Reactor. Some preliminary results of these measurements are presented

  18. Radioactive sodium waste treatment and conditioning. Review of main aspects

    International Nuclear Information System (INIS)

    This publication reviews the main aspects relating to the treatment and conditioning of radioactive sodium waste. This waste arises from the operation of liquid metal fast reactors (LMFRs). In this type of reactor, sodium (Na) or sodium-potassium alloys (NaK) are used as a low-effect neutron moderating coolant medium for extracting and transferring thermal energy from the core and they represent a significant technical and safety challenge during operation and decommissioning. This publication provides the reader with technologically oriented information on the present status of sodium waste management approaches and recent achievements related to treatment and conditioning, with the objective of facilitating planning and preparatory work for the decommissioning of LMFRs. This publication provides a comprehensive review of the hazards associated with sodium waste management. Given the large quantities of sodium waste arising during decommissioning or reactor refurbishment, as well as the challenges and varied techniques associated with removal of 100% of all sodium and NaK bulk quantities and residues during decommissioning, a hazards review and analysis is a critical component in planning the dismantling and waste management activities. Roughly half of this publication focuses on sodium waste generating, handling and treatment processes. This includes draining sodium and NaK from plant systems; in situ treatment of residual sodium; cutting techniques for pumps, valves, piping and other components; cleaning of components; potential reuse of sodium; and removal of selected radionuclides from sodium waste with the objective of reducing the waste classification or converting it to exempt waste. The focus is on proven techniques and technologies, and each discussed method includes a review of the associated principle or theory, practical applications, advantages and disadvantages, limitations, industry experience, and final waste products. A review is provided of final

  19. Impact of pulmonary hypertension on cardiac surgery.

    Directory of Open Access Journals (Sweden)

    G. Tinică

    2012-08-01

    Full Text Available BACKGROUND: Pulmonary hypertension (PH is a frequent condition in patients with congenital heart diseases and left ventricle diseases. Preoperative PH causes higher mortality rate after heart surgery and adverse cardiac events. METHODS: We performed a prospective study which included 159 patients with preoperative PH that had undergone cardiac surgery between November 2008 and November 2011 in the Institute of Cardiovascular Diseases of Iaşi. 28 patients had class 1.4.4 pulmonary artery hypertension (due to congenital cardiac shunts and 131 patients had class 2 PH (due to left heart diseases. The preoperative echocardiography included: assessment of the left ventricular volume and ejection fraction, systolic pressure in the pulmonary artery; right ventricular end-diastolic diameter; right atrium area indexed for body surface area; pulmonary acceleration/ejection time ratio; TAPSE; determination of the severity of the associated tricuspid regurgitation; pericardial fluid presence. The primary endpoint was perioperative mortality; the secondary endpoints included: pericardial, pleural, hepatic or renal complications; the need for a new surgical procedure; postoperative mechanical ventilation > 24 hours; intensive care unit length of stay; postoperative inotropic support duration; the need for intra-aortic balloon pump; the need for pulmonary vasodilator drugs. RESULTS: The mortality rate was 2.51% and was statistically associated with NYHA IV preoperative class, the pulmonary acceleration/ejection time ratio, TAPSE, the presence of pericardial fluid, the indexed area of the right atrium and the concomitant CABG. Severe pulmonary hypertension(sPAP > 60 mmHg is associated with significant mortality rate increase, longer hospitalization in the intensive care unit, mechanical ventilation over 24 hours, lengthy inotropic support and renal, hepatic and pericardial complications. Residual PH and perioperative right ventricle dysfunction are common

  20. Radiative and rovibrational collisional relaxation of sodium dimer

    Science.gov (United States)

    Bayram, Burcin; Horton, Tim; McFarland, Jacob

    2016-05-01

    Radiative and rovibrational collisional relaxation of sodium dimer of the A1Σu+ (8,30) state have been measured by direct observation of the decay fluorescence. Sodium molecular vapor is created in a heatpipe oven at 600 K and excited using a 6-ns pulsed dye laser pumped by a Nd:YAG, operating at 532 nm. The preliminary lifetime measurement was done by directly acquiring lifetime data through boxcar averager from the stored oscilloscope trace of the fluorescence. Analysis of the exponential decay of the fluorescence allows us to obtain the radiative lifetime. By introducing the argon buffer gas and varying the pressure of the heatpipe, a collisional cross section between excited sodium dimer and ground state argon atom collision can be extracted using Stern-Volmer relation.

  1. Electronic Unit Pump Test Bench Development and Pump Properties Research

    Institute of Scientific and Technical Information of China (English)

    LIU Bo-lan; HUANG Ying; ZHANG Fu-jun; ZHAO Chang-lu

    2006-01-01

    A unit pump test bench is developed on an in-line pump test platform. The bench is composed of pump adapting assembly, fuel supply subsystem, lubricating subsystem and a control unit. A crank angle domain injection control method is given out and the control accuracy can be 0.1° crank degree. The bench can test bot h mechanical unit pump and electronic unit pump. A test model-PLD12 electronic unit pump is tested. Full pump delivery map and some influence factors test is d one. Experimental results show that the injection quantity is linear with the de livery angle. The quantity change rate is 15% when fuel temperature increases 30℃. The delivery quantity per cycle increases 30mg at 28V drive voltage. T he average delivery difference for two same type pumps is 5%. Test results show that the bench can be used for unit pump verification.

  2. Collision Kernels from Velocity-Selective Optical Pumping with Magnetic Depolarization

    CERN Document Server

    Bhamre, T; Kominis, I K; McGuyer, B H; Happer, W

    2013-01-01

    We experimentally demonstrate how magnetic depolarization of velocity-selective optical pumping can be used to single out the collisional cusp kernel best describing spin and velocity relaxing collisions between potassium atoms and low pressure helium. The range of pressures and transverse fields used simulate the novel optical pumping regime pertinent to sodium guidestars employed in adaptive optics. We measure the precession of spin-velocity modes under the application of transverse magnetic fields, simulating the natural configuration of mesospheric sodium optical pumping in the geomagnetic field. We also provide a full theoretical account of the experimental data using the recently developed cusp kernels, which realistically quantify velocity damping collisions in this novel optical pumping regime. A single cusp kernel with a sharpness $s=13\\pm 2$ provides a global fit to the K-He data.

  3. Cardiac fusion and complex congenital cardiac defects in thoracopagus twins: diagnostic value of cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of); Park, Jeong-Jun [University of Ulsan College of Medicine, Asan Medical Center, Department of Pediatric Cardiac Surgery, Seoul (Korea, Republic of); Kim, Ellen Ai-Rhan [University of Ulsan College of Medicine, Asan Medical Center, Division of Neonatology, Department of Pediatrics, Seoul (Korea, Republic of); Won, Hye-Sung [University of Ulsan College of Medicine, Asan Medical Center, Department of Obstetrics and Gynecology, Seoul (Korea, Republic of)

    2014-09-15

    Most thoracopagus twins present with cardiac fusion and associated congenital cardiac defects, and assessment of this anatomy is of critical importance in determining patient care and outcome. Cardiac CT with electrocardiographic triggering provides an accurate and quick morphological assessment of both intracardiac and extracardiac structures in newborns, making it the best imaging modality to assess thoracopagus twins during the neonatal period. In this case report, we highlight the diagnostic value of cardiac CT in thoracopagus twins with an interatrial channel and complex congenital cardiac defects. (orig.)

  4. Accidental monensin sodium intoxication of feedlot cattle.

    Science.gov (United States)

    Schweitzer, D; Kimberling, C; Spraker, T; Sterner, F E; McChesney, A E

    1984-05-15

    Of 1,994 yearling and 2-year-old cattle in a winter feeding program, 117 died within 42 days of being fed toxic amounts of monensin sodium in a liquid protein supplement. Death losses commenced on the third day after ingestion of a toxic amount in the feed. Clinical signs in cattle that died in less than 9 days included anorexia, pica, diarrhea, depression, mild hindlimb ataxia, and dyspnea. Gross necropsy findings in cattle dying in the acute phase of the illness included hydrothorax, ascites, and pulmonary edema, as well as petechial hemorrhages, edema, and yellow streaking in skeletal and cardiac muscle. Cattle dying after 9 days had gray streaks in heart and skeletal muscle, generalized ventral edema, enlarged, firm, bluish discolored liver, and enlarged heart. Microscopic changes in cattle dying in the acute phase (less than 9 days) consisted of pulmonary edema, congestion, and hemorrhage. Cardiac and skeletal muscle had localized areas of edema, hemorrhage, and coagulative necrosis. In cattle dying after 9 days of illness, the changes included lymphocytic infiltration, sarcolemmal nuclear proliferation, and fibrosis in skeletal and cardiac muscle. Lungs contained increased alveolar macrophages and a few neutrophils. Centrilobular necrosis and mild fibrosis were found in the liver. Changes varied somewhat according to the area of heart or skeletal muscle that was affected. Active muscles, eg, those in the heart ventricles and diaphragm, were altered most severely. Intoxication appeared to be a result of sedimentation of monensin in the molasses carrier to give remarkable concentrations of the substance at the bottom of the holding tank. PMID:6735846

  5. Creep in sodium

    International Nuclear Information System (INIS)

    Available information on the creep of austenitic, ferritic and Alloy-800 type steels in liquid sodium is critically reviewed. Creep properties of stainless steels can be affected by element transfer and corrosion. At reactor structural component temperatures environmental effects are likely to be less important than changes due to thermal ageing. At high clad temperatures (7000C) decarburisation may cause the loss of strength and ductility in unstabilised steels while cavity formation may cause embrittlement in stabilised steels. The properties of Alloy 800 are, in some experiments, found to deteriorate while in others they are enhanced. This may be a consequence of the metallurgical complexity of the material or arise from the nature of the various techniques employed. Low alloy ferritic steels tend to decarburise in sodium at temperatures greater than 5000C and this leads to loss of strength and an increase in ductility. High alloy ferritics are immune to this effect and appear to be able to tolerate a degree of carburisation. Although intergranular cracking may be enhanced in liquid sodium the mechanical consequences are not significant and evidence for the existence of an embrittlement effect not associated with element transfer or corrosion is weak. Stress and strain may enhance element transfer at crack tips. However in real cracks the gettering or supply action of the crack faces conditions the chemistry of the cracks in sodium and protects the crack tip from element transfer. Thus creep crack extension rates should be independent of changes in bulk coolant chemistry. (author)

  6. Thermophysical properties of sodium

    International Nuclear Information System (INIS)

    Substitution, inverse and substitution inverse relations in form of regression polynomials were used in calculating saturation pressure and density for thermodynamic and transport properties determination of sodium. Program UNISOAUT/A3 was used in calculating regression polynomials coefficients. (J.P.)

  7. Sodium purification in Rapsodie

    International Nuclear Information System (INIS)

    This report is one of a series of publications presenting the main results of tests carried out during the start-up of the first french fast neutron reactor: Rapsodie. The article presents the sodium purification techniques used in the reactor cooling circuits both from the constructional point of view and with respect to results obtained during the first years working. (author)

  8. Underground pumped hydroelectric storage

    Energy Technology Data Exchange (ETDEWEB)

    Allen, R.D.; Doherty, T.J.; Kannberg, L.D.

    1984-07-01

    Underground pumped hydroelectric energy storage was conceived as a modification of surface pumped storage to eliminate dependence upon fortuitous topography, provide higher hydraulic heads, and reduce environmental concerns. A UPHS plant offers substantial savings in investment cost over coal-fired cycling plants and savings in system production costs over gas turbines. Potential location near load centers lowers transmission costs and line losses. Environmental impact is less than that for a coal-fired cycling plant. The inherent benefits include those of all pumped storage (i.e., rapid load response, emergency capacity, improvement in efficiency as pumps improve, and capacity for voltage regulation). A UPHS plant would be powered by either a coal-fired or nuclear baseload plant. The economic capacity of a UPHS plant would be in the range of 1000 to 3000 MW. This storage level is compatible with the load-leveling requirements of a greater metropolitan area with population of 1 million or more. The technical feasibility of UPHS depends upon excavation of a subterranean powerhouse cavern and reservoir caverns within a competent, impervious rock formation, and upon selection of reliable and efficient turbomachinery - pump-turbines and motor-generators - all remotely operable.

  9. Sodium fluxes in sweet pepper exposed to varying sodium concentrations

    NARCIS (Netherlands)

    Blom-Zandstra, M.; Vogelzang, S.A.; Veen, B.W.

    1998-01-01

    The sodium transport and distribution of sweet pepper (Capsicum annuum L.) under saline conditions were studied after transferring the plants to a sodium-free nutrient solution. Sodium stress up to 60 mM did not affect the growth of sweet pepper, as it appears able to counteract the unfavourable phy

  10. Application of robotics in congenital cardiac surgery.

    Science.gov (United States)

    Cannon, Jeremy W; Howe, Robert D; Dupont, Pierre E; Triedman, John K; Marx, Gerald R; del Nido, Pedro J

    2003-01-01

    Over the past 5 years, robotic systems that combine advanced endoscopic imaging with computer-enhanced instrument control have been used for both coronary revascularization and intracardiac procedures in adults. In addition, endoscope positioning systems and articulated instruments with a robotic wrist mechanism have further expanded the potential applications for robotics in cardiac surgery. In pediatric cardiac surgery, potential applications can be divided into simple scope manipulation versus the use of 3-dimensional imaging and a robotic wrist for dissection and reconstruction. A voice-controlled robotic arm for scope manipulation can facilitate current pediatric thoracoscopic procedures such as ligation of patent ductus arteriosus and division of vascular rings. By using an advanced imaging system along with a robotic wrist, more complex extracardiac and even intracardiac procedures can be performed in children. Examples include coarctation repair, septal defect repair, and mitral or tricuspid valvuloplasty. Furthermore, with adequate intracardiac imaging, a robot-assisted off-pump approach to intracardiac pathology is conceivable. New real-time 3-dimensional echocardiography now offers sufficient resolution to enable such procedures, while the addition of instrument tracking, haptic feedback, and novel tissue fixation devices can facilitate safe and reliable intracardiac repair without extracorporeal circulation. PMID:12740773

  11. Predicting the risk of sudden cardiac death.

    Science.gov (United States)

    Lerma, Claudia; Glass, Leon

    2016-05-01

    Sudden cardiac death (SCD) is the result of a change of cardiac activity from normal (typically sinus) rhythm to a rhythm that does not pump adequate blood to the brain. The most common rhythms leading to SCD are ventricular tachycardia (VT) or ventricular fibrillation (VF). These result from an accelerated ventricular pacemaker or ventricular reentrant waves. Despite significant efforts to develop accurate predictors for the risk of SCD, current methods for risk stratification still need to be improved. In this article we briefly review current approaches to risk stratification. Then we discuss the mathematical basis for dynamical transitions (called bifurcations) that may lead to VT and VF. One mechanism for transition to VT or VF involves a perturbation by a premature ventricular complex (PVC) during sinus rhythm. We describe the main mechanisms of PVCs (reentry, independent pacemakers and abnormal depolarizations). An emerging approach to risk stratification for SCD involves the development of individualized dynamical models of a patient based on measured anatomy and physiology. Careful analysis and modelling of dynamics of ventricular arrhythmia on an individual basis will be essential in order to improve risk stratification for SCD and to lay a foundation for personalized (precision) medicine in cardiology. PMID:26660287

  12. Recent advances in paediatric cardiac anaesthesia

    Directory of Open Access Journals (Sweden)

    Mahesh Vakamudi

    2012-01-01

    Full Text Available Paediatric cardiac anaesthesia involves anaesthetizing very small children with complex congenital heart disease for major surgical procedures. The unique nature of this patient population requires considerable expertise and in-depth knowledge of the altered physiology. There have been several developments in the last decade in this subspecialty that has contributed to better care and improved outcome in this vulnerable group of patients. The purpose of this review is to present some of the recent advances in the anesthetic management of these children from preoperative evaluation to postoperative care. This article reviews the role of magnetic resonance imaging and contrast-enhanced magnetic resonance angiography in preoperative evaluation, the use of ultrasound to secure vascular access, the use of cuffed endotracheal tubes, the optimal haematocrit and the role of blood products, including the use of recombinant factor VIIa. It also deals with the advances in technology that have led to improved monitoring, the newer developments in cardiopulmonary bypass, the use of centrifugal pumps and extracorporeal membrane oxygenation and the role of DHCA. The role of new drugs, especially the α-2 agonists in paediatric cardiac anesthetic practice, fast tracking and effective postoperative pain management have also been reviewed.

  13. Sodium Channels in Pain and Cancer: New Therapeutic Opportunities.

    Science.gov (United States)

    Luiz, Ana Paula; Wood, John N

    2016-01-01

    Voltage-gated sodium channels (VGSCs) underpin electrical activity in the nervous system through action potential propagation. First predicted by the modeling studies of Hodgkin and Huxley, they were subsequently identified at the molecular level by groups led by Catterall and Numa. VGSC dysfunction has long been linked to neuronal and cardiac disorders with some nonselective sodium channel blockers in current use in the clinic. The lack of selectivity means that side effect issues are a major impediment to the use of broad spectrum sodium channel blockers. Nine different sodium channels are known to exist, and selective blockers are now being developed. The potential utility of these drugs to target diseases ranging from migraine, multiple sclerosis, muscle, and immune system disorders, to cancer and pain is being explored. Four channels are potential targets for pain disorders. This conclusion comes from mouse knockout studies and human mutations that prove the involvement of Nav1.3, Nav1.7, Nav1.8, and Nav1.9 in the development and maintenance of acute and chronic pain. In this chapter, we present a short overview of the possible role of Nav1.3, Nav1.7, Nav1.8, and Nav1.9 in human pain and the emerging and unexpected role of sodium channels in cancer pathogenesis. PMID:26920012

  14. Inhibition of collagen synthesis by select calcium and sodium channel blockers can be mitigated by ascorbic acid and ascorbyl palmitate

    OpenAIRE

    Ivanov, Vadim; Ivanova, Svetlana; KALINOVSKY, TATIANA; NIEDZWIECKI, ALEKSANDRA; RATH, MATTHIAS

    2016-01-01

    Calcium, sodium and potassium channel blockers are widely prescribed medications for a variety of health problems, most frequently for cardiac arrhythmias, hypertension, angina pectoris and other disorders. However, chronic application of channel blockers is associated with numerous side effects, including worsening cardiac pathology. For example, nifedipine, a calcium-channel blocker was found to be associated with increased mortality and increased risk for myocardial infarction. In addition...

  15. Technology for sodium purity control

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ji Young; Kim, B. H.; Kim, T. J. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-10-01

    When sodium is used as heat transfer fluid, the plugging in coolant flow, the corrosion of structure material and the transfer of radioactive material caused by the impurities in sodium are worth considerable. Accordingly, these impurities must be monitored and controlled continuously by sodium purification devices in the heat transfer system which sodium is used as coolant. Sodium purification loop was constructed for the purpose of accumulating the technology for purity control of the coolant, developing and verifying further efficient instruments for sodium purification. The plugging meter and the cold trap is used as the implement for measuring and controlling the oxygen and the hydrogen, the main impurities in sodium coolant. They are capable of excellent performance as the implements which could detect and monitor the impurities to the concentration limit required for nuclear reactor. Sodium purification loop could be used variably according to the experimental purpose. 18 refs., 34 figs., 8 tabs. (Author)

  16. Approximate analytical solutions for excitation and propagation in cardiac tissue

    Science.gov (United States)

    Greene, D'Artagnan; Shiferaw, Yohannes

    2015-04-01

    It is well known that a variety of cardiac arrhythmias are initiated by a focal excitation in heart tissue. At the single cell level these currents are typically induced by intracellular processes such as spontaneous calcium release (SCR). However, it is not understood how the size and morphology of these focal excitations are related to the electrophysiological properties of cardiac cells. In this paper a detailed physiologically based ionic model is analyzed by projecting the excitation dynamics to a reduced one-dimensional parameter space. Based on this analysis we show that the inward current required for an excitation to occur is largely dictated by the voltage dependence of the inward rectifier potassium current (IK 1) , and is insensitive to the detailed properties of the sodium current. We derive an analytical expression relating the size of a stimulus and the critical current required to induce a propagating action potential (AP), and argue that this relationship determines the necessary number of cells that must undergo SCR in order to induce ectopic activity in cardiac tissue. Finally, we show that, once a focal excitation begins to propagate, its propagation characteristics, such as the conduction velocity and the critical radius for propagation, are largely determined by the sodium and gap junction currents with a substantially lesser effect due to repolarizing potassium currents. These results reveal the relationship between ion channel properties and important tissue scale processes such as excitation and propagation.

  17. Cardiac arrest in children

    Directory of Open Access Journals (Sweden)

    Tress Erika

    2010-01-01

    Full Text Available Major advances in the field of pediatric cardiac arrest (CA were made during the last decade, starting with the publication of pediatric Utstein guidelines, the 2005 recommendations by the International Liaison Committee on Resuscitation, and culminating in multicenter collaborations. The epidemiology and pathophysiology of in-hospital and out-of-hospital CA are now well described. Four phases of CA are described and the term "post-cardiac arrest syndrome" has been proposed, along with treatment goals for each of its four phases: immediate post-arrest, early post-arrest, intermediate and recovery phase. Hypothermia is recommended to be considered as a therapy for post-CA syndrome in comatose patients after CA, and large multicenter prospective studies are underway. We reviewed landmark articles related to pediatric CA published during the last decade. We present the current knowledge of epidemiology, pathophysiology and treatment of CA relevant to pre-hospital and acute care health practitioners.

  18. Cardiac arrest in children.

    Science.gov (United States)

    Tress, Erika E; Kochanek, Patrick M; Saladino, Richard A; Manole, Mioara D

    2010-07-01

    Major advances in the field of pediatric cardiac arrest (CA) were made during the last decade, starting with the publication of pediatric Utstein guidelines, the 2005 recommendations by the International Liaison Committee on Resuscitation, and culminating in multicenter collaborations. The epidemiology and pathophysiology of in-hospital and out-of-hospital CA are now well described. Four phases of CA are described and the term "post-cardiac arrest syndrome" has been proposed, along with treatment goals for each of its four phases: immediate post-arrest, early post-arrest, intermediate and recovery phase. Hypothermia is recommended to be considered as a therapy for post-CA syndrome in comatose patients after CA, and large multicenter prospective studies are underway. We reviewed landmark articles related to pediatric CA published during the last decade. We present the current knowledge of epidemiology, pathophysiology and treatment of CA relevant to pre-hospital and acute care health practitioners. PMID:20930971

  19. Socially differentiated cardiac rehabilitation

    DEFF Research Database (Denmark)

    Meillier, Lucette Kirsten; Nielsen, Kirsten Melgaard; Larsen, Finn Breinholt;

    2012-01-01

    recruitment and participation among low educated and socially vulnerable patients must be addressed to lower inequality in post-MI health. Our aim was to improve referral, attendance, and adherence rates among socially vulnerable patients by systematic screening and by offering a socially differentiated...... standard rehabilitation programme (SRP). If patients were identified as socially vulnerable, they were offered an extended version of the rehabilitation programme (ERP). Excluded patients were offered home visits by a cardiac nurse. Concordance principles were used in the individualised programme elements......%. Patients were equally distributed to the SRP and the ERP. No inequality was found in attendance and adherence among referred patients. Conclusions: It seems possible to overcome unequal referral, attendance, and adherence in cardiac rehabilitation by organisation of systematic screening and social...

  20. Automatic Implantable Cardiac Defibrillator

    Medline Plus

    Full Text Available ... blood’s not pumped from the heart to the brain, the brain immediately shuts down. Then you have the impression ... rescued. If blood doesn't go to your brain in five seconds you're out, you pass ...

  1. Automatic Implantable Cardiac Defibrillator

    Medline Plus

    Full Text Available ... syncope. You have the heart disease, you have coronary artery disease, you have dilated cardiomyopathy, you have bypass, you ... My heart is not pumping well, I have coronary artery disease, what my chance of sudden is very high, ...

  2. Automatic Implantable Cardiac Defibrillator

    Medline Plus

    Full Text Available ... to do it is to talk to our doctor. You see a doctor. My heart is not pumping well, I have ... have any issue, any symptom, go to your doctor. Your doctor will do a couple of study ...

  3. Cardiac metastases of osteosarcoma

    International Nuclear Information System (INIS)

    Osteosarcoma is a malignancy whose various sites of metastasis greatly modify its ultimate prognosis. We report a case of simultaneous pulmonary and cardiac metastases in a 41-year-old male patient with osteosarcoma of the tibia, presenting after more then one year of completion of adjuvant therapy with progressive dyspnea and cyanosis. Diagnosis was made on computerized tomogram and echocardiogram. The metastatic mass entirely occupying the right ventricle and the pulmonary artery proved fatal. (author)

  4. Cardiac Tissue Engineering

    OpenAIRE

    MILICA RADISIC; GORDANA VUNJAK-NOVAKOVIC

    2009-01-01

    We hypothesized that clinically sized (1-5 mm thick),compact cardiac constructs containing physiologically high density of viable cells (~108 cells/cm3) can be engineered in vitro by using biomimetic culture systems capable of providing oxygen transport and electrical stimulation, designed to mimic those in native heart. This hypothesis was tested by culturing rat heart cells on polymer scaffolds, either with perfusion of culture medium (physiologic interstitial velocity, supplementation of p...

  5. Cardiac developmental toxicity

    OpenAIRE

    Mahler, Gretchen J.; Jonathan T Butcher

    2011-01-01

    Congenital heart disease is a highly prevalent problem with mostly unknown origins. Many cases of CHD likely involve an environmental exposure coupled with genetic susceptibility, but practical and ethical considerations make nongenetic causes of CHD difficult to assess in humans. The development of the heart is highly conserved across all vertebrate species, making animal models an excellent option for screening potential cardiac teratogens. This review will discuss exposures known to cause ...

  6. Penetrating Cardiac Injuries

    OpenAIRE

    ÖZYAZICIOĞLU, Ahmet

    2002-01-01

    Objectives: To present our experience of penetrating cardiac injuries treated at Atatürk University hospital; in 17 years 38 patients were analyzed. Methods: Patients were classified into three groups: group A (stable), 12; group B (shock), 21; and group C (agonal), five. Five patients were treated by pericardial window and three by pericardiocentesis. Two patients in group C, 19 patients in group B and five patients in group A underwent median sternotomy or thoracotomy in the operating room...

  7. Fluid pumping apparatus

    Science.gov (United States)

    West, Phillip B.

    2006-01-17

    A method and apparatus suitable for coupling seismic or other downhole sensors to a borehole wall in high temperature and pressure environments. In one embodiment, one or more metal bellows mounted to a sensor module are inflated to clamp the sensor module within the borehole and couple an associated seismic sensor to a borehole wall. Once the sensing operation is complete, the bellows are deflated and the sensor module is unclamped by deflation of the metal bellows. In a further embodiment, a magnetic drive pump in a pump module is used to supply fluid pressure for inflating the metal bellows using borehole fluid or fluid from a reservoir. The pump includes a magnetic drive motor configured with a rotor assembly to be exposed to borehole fluid pressure including a rotatable armature for driving an impeller and an associated coil under control of electronics isolated from borehole pressure.

  8. Miniature Lightweight Ion Pump

    Science.gov (United States)

    Sinha, Mahadeva P.

    2010-01-01

    This design offers a larger surface area for pumping of active gases and reduces the mass of the pump by eliminating the additional vacuum enclosure. There are three main components to this ion pump: the cathode and anode pumping elements assembly, the vacuum enclosure (made completely of titanium and used as the cathode and maintained at ground potential) containing the assembly, and the external magnet. These components are generally put in a noble diode (or differential) configuration of the ion pump technology. In the present state of the art, there are two cathodes, one made of titanium and the other of tantalum. The anodes are made up of an array of stainless steel cylinders positioned between the two cathodes. All the elements of the pump are in a vacuum enclosure. After the reduction of pressure in this enclosure to a few microns, a voltage is applied between the cathode and the anode elements. Electrons generated by the ionization are accelerated toward the anodes that are confined in the anode space by the axial magnetic field. For the generation of the axial field along the anode elements, the magnet is designed in a C-configuration and is fabricated from rare earth magnetic materials (Nd-B-Fe or Sm-Co) possessing high energy product values, and the yoke is fabricated from the high permeability material (Hiperco-50A composed of Fe-Co-V). The electrons in this region collide with the gas molecules and generate their positive ions. These ions are accelerated into the cathode and eject cathode material (Ti). The neutral atoms deposit on the anode surfaces. Because of the chemical activity of Ti, the atoms combine with chemically active gas molecules (e.g. N2, O2, etc.) and remove them. New layers of Ti are continually deposited, and the pumping of active gases is thus accomplished. Pumping of the inert gases is accomplished by their burial several atomic layers deep into the cathode. However, they tend to re-emit if the entrapping lattice atoms are

  9. Benign cardiac tumours: cardiac CT and MRI imaging appearances

    International Nuclear Information System (INIS)

    Full text: Primary benign cardiac tumours are rarely found in clinical practice and are generally evaluated with echocardiography. However, with the increasing usage of helical multislice CT, the initial detection and evaluation of these masses may be made by the radiologist during routine daily practice for other indications. The echocardiographic, CT and cardiac MRI appearances of various benign cardiac tumours and masses are described and illustrated in this review

  10. Crystal structure of the plasma membrane proton pump

    DEFF Research Database (Denmark)

    Pedersen, Bjørn P.; Buch-Pedersen, Morten Jeppe; Morth, J. Preben;

    2007-01-01

    -3, and Na1,K1-ATPase (the sodium-potassium pump) in animals4. The name P-type derives from the fact that these proteins exploit a phosphorylated reaction cycle intermediate of ATP hydrolysis5.The plasma membrane proton pumps belong to the type III P-type ATPase subfamily, whereas Na1,K1-ATPase and Ca21......A prerequisite for life is the ability to maintain electrochemical imbalances across biomembranes. In all eukaryotes the plasma membrane potential and secondary transport systems are energized by the activity of P-type ATPase membrane proteins: H1-ATPase (the proton pump) in plants and fungi1...... functional unit of ATP-coupled proton transport across the plasma membrane, and the structure is locked in a functional state not previously observed in P-type ATPases. The transmembrane domain reveals a large cavity, which is likely to be filled with water, located near the middle of the membrane plane...

  11. Cardiac tissue engineering

    Directory of Open Access Journals (Sweden)

    MILICA RADISIC

    2005-03-01

    Full Text Available We hypothesized that clinically sized (1-5 mm thick,compact cardiac constructs containing physiologically high density of viable cells (~108 cells/cm3 can be engineered in vitro by using biomimetic culture systems capable of providing oxygen transport and electrical stimulation, designed to mimic those in native heart. This hypothesis was tested by culturing rat heart cells on polymer scaffolds, either with perfusion of culture medium (physiologic interstitial velocity, supplementation of perfluorocarbons, or with electrical stimulation (continuous application of biphasic pulses, 2 ms, 5 V, 1 Hz. Tissue constructs cultured without perfusion or electrical stimulation served as controls. Medium perfusion and addition of perfluorocarbons resulted in compact, thick constructs containing physiologic density of viable, electromechanically coupled cells, in contrast to control constructs which had only a ~100 mm thick peripheral region with functionally connected cells. Electrical stimulation of cultured constructs resulted in markedly improved contractile properties, increased amounts of cardiac proteins, and remarkably well developed ultrastructure (similar to that of native heart as compared to non-stimulated controls. We discuss here the state of the art of cardiac tissue engineering, in light of the biomimetic approach that reproduces in vitro some of the conditions present during normal tissue development.

  12. Slicing sodium from bakery products

    NARCIS (Netherlands)

    Noort, M.

    2012-01-01

    The need for sodium reduction in our diet is clear to consumers, dieticians and food manufacturers. As sodium concentration has a strengthening effect on gluten, sodium reduction decreases dough mixing tolerance, dough resistance and induces dough stickiness. In particular, the latter may cause prob

  13. Reactor coolant pump flywheel

    Science.gov (United States)

    Finegan, John Raymond; Kreke, Francis Joseph; Casamassa, John Joseph

    2013-11-26

    A flywheel for a pump, and in particular a flywheel having a number of high density segments for use in a nuclear reactor coolant pump. The flywheel includes an inner member and an outer member. A number of high density segments are provided between the inner and outer members. The high density segments may be formed from a tungsten based alloy. A preselected gap is provided between each of the number of high density segments. The gap accommodates thermal expansion of each of the number of segments and resists the hoop stress effect/keystoning of the segments.

  14. Heat pump planning handbook

    CERN Document Server

    Bonin, Jürgen

    2015-01-01

    The Heat Pump Planning Handbook contains practical information and guidance on the design, planning and selection of heat pump systems, allowing engineers, designers, architects and construction specialists to compare a number of different systems and options. Including detailed descriptions of components and their functions and reflecting the current state of technology this guide contains sample tasks and solutions as well as new model calculations and planning evaluations. Also economic factors and alternative energy sources are covered, which are essential at a time of rising heat costs. T

  15. Noise through Quantum Pumps

    OpenAIRE

    Polianski, M. L.; Vavilov, M. G.; Brouwer, P.W.

    2002-01-01

    We study the current noise through an unbiased quantum electron pump and its mesoscopic fluctuations for arbitrary temperatures and beyond the bilinear response. In the bilinear regime, we find the full distributions of the noise power and the current-to-noise ratio for a chaotic quantum dots with single-channel and many-channel ballistic point contacts. For a dot with many-channel point contacts we also calculate the ensemble-averaged noise at arbitrary temperature and pumping strength. In t...

  16. Air-Operated Sump Pump

    Science.gov (United States)

    Nolt, Gary D.

    1988-01-01

    Pump removes liquid seepage from small, restricted area and against large pressure head. Developed for moving small amounts of water and oil from sump pit 85 ft (25.91 m) deep. Fits in space only 6 1/2 in. (16.5 cm) in diameter and 18 in. (45.7 cm) long. In discharge part of pumping cycle, air forces liquid out of pump chamber through pipe. During filling part of pumping cycle, water enters pump chamber from sump pit. Float in chamber next to pump chamber controls pressurization through timer and solenoid valve.

  17. French sodium waste storage rules

    International Nuclear Information System (INIS)

    In the frame of Superphenix Plant decommissioning, CEA and EDF had to determine the rules to applied for safe sodium waste storage. Even if sodium waste storage has been monitored for some decades (but only during Operational Plant phases), some recent events showed that this item had to be secured before beginning large decommissioning operations. Of course, the best way would be an on-line treatment but operational constraints always imply a delay in this operation. Indeed, a number of sodium wastes will be produced during the period before the end of Superphenix sodium treatment (planned in 2013) and will have to wait for further treatment. The events to be avoided, or at least taken into account, are uncontrolled sodium reaction with air moisture (large hydrogen production, important overheating) and sodium reaction with liquid water (pressure waves, large hydrogen production, important overheating). Careful analysis of all abnormal events in sodium waste storage disposal was performed and led to rule evolution. In 2004, experimental studies were undertaken, in order to know how solid sodium at room temperature reacts with air humidity: the conditions of aqueous sodium hydroxide production (which is the main risk source in sodium waste storage) have been observed. On this basis, new general safe rules for sodium waste storage have been raised: - Waste classifying: pure sodium and soda to be separated, bulk and residues to be separated - Sodium waste containers: tight, dry, easy to refill with gas, protected against overpressure effect, with specific marking and reference - Dedicated rooms: dry, with specific markings, with specific sodium fire extinguishers - Maximum duration: three months before next refill with inert dry gas, in an over-container if more than one year - Dry gas feeling: inert gas except for sodium film residues (dry air) 395 For Superphenix application, packaging and storage conditions of sodium wastes have been defined, in accordance with

  18. Indeterminacy of Spatiotemporal Cardiac Alternans

    CERN Document Server

    Zhao, Xiaopeng

    2007-01-01

    Cardiac alternans, a beat-to-beat alternation in action potential duration (at the cellular level) or in ECG morphology (at the whole heart level), is a marker of ventricular fibrillation, a fatal heart rhythm that kills hundreds of thousands of people in the US each year. Investigating cardiac alternans may lead to a better understanding of the mechanisms of cardiac arrhythmias and eventually better algorithms for the prediction and prevention of such dreadful diseases. In paced cardiac tissue, alternans develops under increasingly shorter pacing period. Existing experimental and theoretical studies adopt the assumption that alternans in homogeneous cardiac tissue is exclusively determined by the pacing period. In contrast, we find that, when calcium-driven alternans develops in cardiac fibers, it may take different spatiotemporal patterns depending on the pacing history. Because there coexist multiple alternans solutions for a given pacing period, the alternans pattern on a fiber becomes unpredictable. Usin...

  19. Biosynthesis of cardiac natriuretic peptides

    DEFF Research Database (Denmark)

    Goetze, Jens Peter

    2010-01-01

    Cardiac-derived peptide hormones were identified more than 25 years ago. An astonishing amount of clinical studies have established cardiac natriuretic peptides and their molecular precursors as useful markers of heart disease. In contrast to the clinical applications, the biogenesis of cardiac p...... competent endocrine cells. The structurally related atrial natriuretic peptide will be mentioned where appropriate, whereas C-type natriuretic peptide will not be considered as a cardiac peptide of relevance in mammalian physiology....... characterized. An ongoing characterization of the molecular heterogeneity will help appreciate the biosynthetic capacity of the endocrine heart and could introduce new diagnostic possibilities. Notably, different biosynthetic products may not be equal markers of the same pathophysiological processes. An...... inefficient post-translational prohormone maturation will also affect the biology of the cardiac natriuretic peptide system. This review aims at summarizing the myocardial synthesis of natriuretic peptides focusing on B-type natriuretic peptide, where new data has disclosed cardiac myocytes as highly...

  20. Biosynthesis of cardiac natriuretic peptides

    DEFF Research Database (Denmark)

    Goetze, Jens Peter

    2010-01-01

    Cardiac-derived peptide hormones were identified more than 25 years ago. An astonishing amount of clinical studies have established cardiac natriuretic peptides and their molecular precursors as useful markers of heart disease. In contrast to the clinical applications, the biogenesis of cardiac...... inefficient post-translational prohormone maturation will also affect the biology of the cardiac natriuretic peptide system. This review aims at summarizing the myocardial synthesis of natriuretic peptides focusing on B-type natriuretic peptide, where new data has disclosed cardiac myocytes as highly...... competent endocrine cells. The structurally related atrial natriuretic peptide will be mentioned where appropriate, whereas C-type natriuretic peptide will not be considered as a cardiac peptide of relevance in mammalian physiology....

  1. An overview of cardiac morphogenesis.

    Science.gov (United States)

    Schleich, Jean-Marc; Abdulla, Tariq; Summers, Ron; Houyel, Lucile

    2013-11-01

    Accurate knowledge of normal cardiac development is essential for properly understanding the morphogenesis of congenital cardiac malformations that represent the most common congenital anomaly in newborns. The heart is the first organ to function during embryonic development and is fully formed at 8 weeks of gestation. Recent studies stemming from molecular genetics have allowed specification of the role of cellular precursors in the field of heart development. In this article we review the different steps of heart development, focusing on the processes of alignment and septation. We also show, as often as possible, the links between abnormalities of cardiac development and the main congenital heart defects. The development of animal models has permitted the unraveling of many mechanisms that potentially lead to cardiac malformations. A next step towards a better knowledge of cardiac development could be multiscale cardiac modelling. PMID:24138816

  2. Is the human left ventricle partially a fractal pump?

    Science.gov (United States)

    Moore, Brandon; Dasi, Lakshmi

    2011-11-01

    Ventricular systolic and diastolic dysfunctions represent a large portion of healthcare problems in the United States. Many of these problems are caused and/or characterized by their altered fluid-structure mechanics. The structure of the left ventricle in particular is complex with time dependent multi-scale geometric complexity. At relatively small scales, one facet that is still not well understood is the role of trabeculae in the pumping function of the left ventricle. We utilize fractal geometry tools to help characterize the complexity of the inner surface of the left ventricle at different times during the cardiac cycle. A high-resolution three dimensional model of the time dependent ventricular geometry was constructed from computed tomography (CT) images in a human. The scale dependent fractal dimension of the ventricle was determined using the box-counting algorithm over the cardiac cycle. It is shown that the trabeculae may indeed play an integral role in the biomechanics of pumping by regulating the mechanical leverage available to the cardiac muscle fibers.

  3. Conceptual design of advanced central receiver power systems sodium-cooled receiver concept. Volume 2, Book 1. Commercial plant conceptual design. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1979-03-01

    The conceptual design of the 100-MW solar tower focus commercial power plant is described in detail. Sodium is pumped up to the top of a tall tower where the receiver is located. The sodium is heated in the receiver and then flows down the tower, through a pressure reducing device, and thence into a large, hot storage tank which is located at ground level and whose size is made to meet a specific thermal energy storage capacity requirement. From this tank, the sodium is pumped by a separate pump, through a system of sodium-to-water steam generators. The steam generator system consists of a separate superheater and reheater operating in parallel and an evaporator unit operating in series with the other two units. The sodium flowing from the evaporator unit is piped to a cold storage tank. From the cold storage tank, sodium is then pumped up to the tip of the tower to complete the cycle. The steam generated in the steam generators is fed to a conventional off-the-shelf, high-efficiency turbine. The steam loop operates in a conventional rankine cycle with the steam generators serving the same purpose as a conventional boiler and water being fed to the evaporator with conventional feedwater pumps. The pressure reducing device (a standard drag valve, for example) serves to mitigate the pressure caused by the static head of sodium and thus allows the large tanks to operate at ambient pressure conditions. (WHK)

  4. Aquaflo pump vs FMS 4 pump for shoulder arthroscopic surgery.

    OpenAIRE

    Ampat, G.; Bruguera, J.; Copeland, S A

    1997-01-01

    A prospective controlled trial was carried out to compare two different fluid delivery systems used for shoulder arthroscopy. One an advanced pump system that controls both pressure and flow of fluid delivered, the other an air-driven diaphragm pump that only controls fluid pressure. Blood loss, presence of bleeding vessels and visual clarity were parameters used to assess the pump systems. There was no difference between the pumps in straightforward shoulder procedures. However, complicated ...

  5. Sudden Cardiac Death in Athletes.

    Science.gov (United States)

    Wasfy, Meagan M; Hutter, Adolph M; Weiner, Rory B

    2016-01-01

    There are clear health benefits to exercise; even so, patients with cardiac conditions who engage in exercise and athletic competition may on rare occasion experience sudden cardiac death (SCD). This article reviews the epidemiology and common causes of SCD in specific athlete populations. There is ongoing debate about the optimal mechanism for SCD prevention, specifically regarding the inclusion of the ECG and/or cardiac imaging in routine preparticipation sports evaluation. This controversy and contemporary screening recommendations are also reviewed. PMID:27486488

  6. Cardiac Rehabilitation: Guidelines and Recommendations

    OpenAIRE

    Catherine Monpere

    1998-01-01

    Cardiac rehabilitation has been shown to improve exercise tolerance and symptomatology in patients experiencing angina or heart failure and reduce long term mortality after myocardial infarction, with a good cost-effectiveness ratio. In addition to these `hard' endpoints, cardiac rehabilitation improves the patient's quality of life and risk factor profile through a multifactorial intervention. Indeed, cardiac rehabilitation is no longer restricted to physical reconditioning, but should now b...

  7. Development of Sodium Technology

    International Nuclear Information System (INIS)

    The basic P and ID and fabrication method for IHTS simplification experiment were prepared for the experimental apparatus. In order to investigate the later phase of a SWR event, an experimental apparatus was designed and manufactured. The 620 data set have been obtained in the experiment of free surface fluctuation and an experimental correlation for the critical gas entertainment condition is additionally developed. For development of water into sodium leak detection technology, the properties from leak noises were extracted, and the tools for analyzing acoustic noises were constructed. The state-of-the-art on the flow and differential pressure measuring techniques in the piping system is investigated to develop new techniques which are applicable to high temperature sodium flow environment. The plan for the minimization of errors in temperature measurement was drawn up by analysing the error factors in temperature measurement. And the countermeasures for the minimization of errors in temperature measurement due to complex heat transfer were prepared

  8. Specialists' meeting on sodium fires

    International Nuclear Information System (INIS)

    The four sessions of the meeting covered the following topics: 1. general approach to fast reactor safety, standards of fire safety, maximum design basis accidents for sodium leaks and fires, status of sodium fires in different countries; 2. physical and chemical processes during combustion of sodium and its interaction with structural and technological materials and methods for structural protection; 3. methods of sodium fires extinguishing and measures for localizing aerosol combustion products, organization of fire fighting procedures, instruction and training of fire personnel; 4. elimination of the consequences of sodium fires

  9. Sodium source development for pulsed power driven, photopumped NA/NE x-ray laser experiments

    International Nuclear Information System (INIS)

    A sodium plasma source is being developed for a resonant photopumping x-ray laser scheme in which the 11A 1s2 - 1s2rho 1P1 line in heliumlike Na X is used to pump the Ne IX n=4 singlet level. In their experiment the NRL Gamble II generator is used to produce two z-pinch plasmas in a side-by-side geometry. The sodium plasma is produced on axis and conducts the full 1 MA machine current. A fraction of this current returns through a neon gas puff located 5 cm from the sodium. This separation is determined by the need to prevent the plasmas from mixing and the need to have each plasma's azimuthal magnetic field as symmetric as possible. A minimum separation is desirable to increase coupling efficiency. To improve the pump source, a more confined source of pure sodium involving a coaxial plasma gun is being developed. They are currently studying both the operation of this source on a test stand and implosions of the resulting plasma on Gamble II. In initial experiments aluminum is substituted for sodium. Test stand diagnostics include photodiodes, witness plates, and current monitors designed to investigate the early motion of the annular plasma. Results from test stand and Gamble II experiments with both aluminum and sodium, as well as sodium handling techniques, are presented

  10. Piston for rod pumping

    Energy Technology Data Exchange (ETDEWEB)

    Pastushenko, G.I.

    1965-06-22

    A piston, or plunger, for rod pumping, is made up of a cylindrical housing with labryinthal seals, a nose piece, and a scraper. In order to remove paraffin from the inside surface of the production pipe, the housing is made in telescopic form. The scraper consists of an arrangement of springs installed on the outer surface of the housing.

  11. Pump Flow Analysis

    Science.gov (United States)

    1981-01-01

    Ingersoll-Rand Research, Inc.'s use of COSMIC's computer program MERIDL permits designers to evaluate performance and efficiency characteristics to be expected from the pump's impeller. It also provides information that enables a trained hydraulic engineer to make design improvements. Company was able to avoid the cost of developing new software and to improve some product design features.

  12. Diagnostic imaging of cardiac hypertrophy

    International Nuclear Information System (INIS)

    As imaging techniques for cardiac hypertrophy, the ultrasonic dimension gauze technique, echocardiography, ventriculography and the RI technique including emission RI tomography were outlined. (Chiba, N.)

  13. Synopsis on remarks on the topics of the agenda, presentated for informal discussion during the Specialists Meeting on Operational Safety of Sodium Circuits on 17 to 20 March 1971

    International Nuclear Information System (INIS)

    The work done in the Sodium field by the Department of Nuclear Reactor Technology of the Central Technical Institute TNO at Apeldoorn, consists mainly of the design, construction and operation of sodium test rigs, four of which are rigs for the investigation of corrosion phenomena. Research and development on sodium pumps, electromagnetic brakes, large valves, forced circulation cold traps, vapor traps, electrical trace heating, instrumentation, impurity monitoring, in-line distillation and sodium chemistry

  14. Fuel Pumping System And Method

    Science.gov (United States)

    Shafer, Scott F.; Wang, Lifeng

    2005-12-13

    A fuel pumping system that includes a pump drive is provided. A first pumping element is operatively connected to the pump drive and is operable to generate a first flow of pressurized fuel. A second pumping element is operatively connected to the pump drive and is operable to generate a second flow of pressurized fuel. A first solenoid is operatively connected to the first pumping element and is operable to vary at least one of a fuel pressure and a fuel flow rate of the first flow of pressurized fuel. A second solenoid is operatively connected to the second pumping element and is operable to vary at least one of a fuel pressure and a fuel flow rate of the second flow of pressurized fuel.

  15. Optimization of compound gear pump

    Institute of Scientific and Technical Information of China (English)

    栾振辉

    2002-01-01

    This paper introduces the performances of compound gear pump. Based on the target of having the smallest mass per unit volume, the paper established a mathematical model of optimization, and obtained the results of optimization of the pump.

  16. Orbital Liquid Oxygen Pump Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposed work will develop a pump, which is based on two novel and unique design features. The first feature is a lobed pumping mechanism which operates with...

  17. 21 CFR 184.1736 - Sodium bicarbonate.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Sodium bicarbonate. 184.1736 Section 184.1736 Food... Specific Substances Affirmed as GRAS § 184.1736 Sodium bicarbonate. (a) Sodium bicarbonate (NaHCO3, CAS Reg. No. 144-55-8) is prepared by treating a sodium carbonate or a sodium carbonate and sodium...

  18. CFD Modeling of Sodium Fires

    International Nuclear Information System (INIS)

    A sodium cooled fast reactor is one of the attractive concepts for the 4th generation nuclear reactors. For the safety of a sodium cooled fast reactor, sodium-air and sodium-water reactions must be avoided. A sodium-air reaction typically occurs in two dominant modes, namely the spray fire and the pool fire. To avoid sodium-air accidents and to deal with their consequences, it is essential to understand the physical phenomena. Numerical modeling is one of the methods, which can be used to understand all the physics involved. This paper will present new numerical methods to model sodium pool combustion based on advanced state-of-the-art Computational Fluid Dynamics techniques. The models have been developed, implemented and validated against available experimental data of Newman and Payne. (author)

  19. Blood Pump Bearing System

    Science.gov (United States)

    Aber, Gregory S. (Inventor)

    2000-01-01

    An apparatus is provided for a blood pump bearing system within a pump housing to support long-term highspeed rotation of a rotor with an impeller blade having a plurality of individual magnets disposed thereon to provide a small radial air gap between the magnets and a stator of less than 0.025 inches. The bearing system may be mounted within a flow straightener, diffuser, or other pump element to support the shaft of a pump rotor. The bearing system includes a zirconia shaft having a radiused end. The radiused end has a first radius selected to be about three times greater than the radius of the zirconia shaft. The radiused end of the zirconia shaft engages a flat sapphire endstone. Due to the relative hardness of these materials a flat is quickly produced during break-in on the zirconia radiused end of precisely the size necessary to support thrust loads whereupon wear substantially ceases. Due to the selection of the first radius, the change in shaft end-play during pump break-in is limited to a total desired end-play of less than about 0.010 inches. Radial loads are supported by an olive hole ring jewel that makes near line contact around the circumference of the Ir shaft to support big speed rotation with little friction. The width of olive hole ring jewel is small to allow heat to conduct through to thereby prevent heat build-up in the bearing. A void defined by the bearing elements may fill with blood that then coagulates within the void. The coagulated blood is then conformed to the shape of the bearing surfaces.

  20. Absorption heat pumps

    Science.gov (United States)

    Huhtinen, M.; Heikkilae, M.; Andersson, R.

    1987-03-01

    The aim of the study was to analyze the technical and economic feasibility of absorption heat pumps in Finland. The work was done as a case study: the technical and economic analyses have been carried out for six different cases, where in each the suitable size and type of the heat pump plant and the auxiliary components and connections were specified. The study also detailed the costs concerning the procurement, installation and test runs of the machinery, as well as the savings in energy costs incurred by the introduction of the plant. Conclusions were drawn of the economic viability of the applications studied. The following cases were analyzed: heat recovery from flue gases and productin of district heat in plants using peat, natural gas, and municipal wastes as a fuel. Heat recovery in the pulp and paper industry for the upgrading of pressure of secondary steam and for the heating of white liquor and combustion and drying the air. Heat recovery in a peat-fulled heat and power plant from flue gases that have been used for the drying of peat. According to the study, the absorption heat pump suits best to the production of district heat, when the heat source is the primary energy is steam produced by the boiler. Included in the flue as condensing is the purification of flue gases. Accordingly, benefit is gained on two levels in thick applications. In heat and power plants the use of absorption heat pumps is less economical, due to the fact that the steam used by the pump reduces the production of electricity, which is rated clearly higher than heat.

  1. The examination and replacement of electromagnetic pump from FFTF primary circuit

    International Nuclear Information System (INIS)

    On November 16, 1984 a leak was discovered in the Fast Flux Test Facility (FFTF) Primary Sodium Sampling System electromagnetic pump. The leak was discovered in the course of routine cell entry to investigate the shorted trace heat element. The purpose of this paper is to describe the circumstances surrounding the occurrence of the leak, the processes involved in producing the leak and efforts taken to minimize their effects on future operation of electromagnetic pumps at FFTF. In addition, the replacement of the pump and recovery of the plant also are described. The relative ease of recovery from this incident is indicative of the overall feasibility of the LMR concept

  2. Design of a Mechanical NaK Pump for Fission Space Power Systems

    Science.gov (United States)

    Mireles, Omar R.; Bradley, David; Godfroy, Thomas

    2010-01-01

    Alkali liquid metal cooled fission reactor concepts are under development for mid-range spaceflight power requirements. One such concept utilizes a sodium-potassium eutectic (NaK) as the primary loop working fluid. Traditionally, linear induction pumps have been used to provide the required flow and head conditions for liquid metal systems but can be limited in performance. This paper details the design, build, and check-out test of a mechanical NaK pump. The pump was designed to meet reactor cooling requirements using commercially available components modified for high temperature NaK service.

  3. A Numerical Modeling of A Vascular Implantable Cardiac Endovascular Assistant (AVICENA)

    Science.gov (United States)

    Rahmani, Shahrokh; Tehrani, Pedram; Karimi, Alireza; Alizadeh, Mansour; Navidbakhsh, Mahdi

    2015-10-01

    Cardiovascular diseases have been recently shown to have a pivotal role in human death and endangers lives of many people around the world. One of the most common cardiovascular diseases is poor performance of left ventricle. In this case, the ventricle cannot pump the blood into the aorta and circulatory system with a suitable power which is required for normal circulatory system. AVICENA is a new cardiac assist device which is implanted into the aorta to help the ventricle to pump the blood into circulatory system with more power and to make a better perfusion of the coronary arteries as well. To reach a desire value of rotational speed of the pump, a control circuit is designed for counterpulsation of AVICENA based on the outcomes from previous studies. This control circuit uses a PID controller. The present study aims to simulate the blood flow through the balloon part of AVICENA in a heart cycle with focusing on the calculation of its pump rotational speed by controlling the electrical current of the pump. Results revealed that the desired rotational speed of the pump can be achieved according to the previous aorta pressure cycle by electrical current control which is higher during balloon inflation in comparison with balloon deflation. These findings may have implications not only for understanding the performance of AVICENA but also to help cardiac mechanics experts to improve the shortcoming of this newborn device.

  4. Myocardial ischemia during intravenous DSA in patients with cardiac disease

    International Nuclear Information System (INIS)

    A prospective study was performed for 48 patients who had histories of angina and were referred for digital subtraction angiography (DSA). Cardiac disease was graded according to the American Heart Association (AHA) functional classification system. Each patient received 2-5 injections of 40-ml diatrizoate meglumine and diatrizoate sodium at 15 ml per second in the superior vena cava. Of the 28 patients in functional Classes I or II, 11% had angina and 32% had definite ischemic ECG changes after the DSA injections. Of the patients in functional Class III 63% had angina, and 58% had definite ischemic ECG changes after the injections. These observed cardiac effects following bolus injections of hypertonic ionic contrast media indicate that special precautions are necessary when performing intravenous DSA examinations on this group of high risk patients

  5. Prediction of EMP cavitation threshold from other than sodium testing

    International Nuclear Information System (INIS)

    An experimental study has been performed to predict the cavitation threshold of electromagnetic pumps from measurements on test models using water and alcohol. Cavitation tests were carried out using water and alcohol test loop on subscale ducts of transparent acrylic resin with reference to an actual pump (1.1m3/min). These data were compared to those obtained from the in-sodium tests on the actual pump. The investigation revealed that the value of Thoma's dimensionless parameter: σ applied to the test model for water and alcohol is quite higher than that of corresponding σ on the actual pump. To minimize the incipient cavitation safety margin, more accurate prediction must be required. In view of this, the authors proposed the dimensionless parameter: σT=σ/W-bare where W-bare denotes the Weber number. This parameter was confirmed to predict the cavitation threshold of electromagnetic pumps with much more accuracy than ever before. It can also be adopted to predict cavitation threshold of other FBR components. (author)

  6. Sludge pumping in water treatment

    International Nuclear Information System (INIS)

    In water treatment processes is frequent to separate residual solids, with sludge shape, and minimize its volume in a later management. the technologies to applicate include pumping across pipelines, even to long distance. In wastewater treatment plants (WWTP), the management of these sludges is very important because their characteristics affect load losses calculation. Pumping sludge can modify its behavior and pumping frequency can concern treatment process. This paper explains advantages and disadvantages of different pumps to realize transportation sludge operations. (Author) 11 refs.

  7. Cardiac manifestations of myotonic dystrophy type 1

    DEFF Research Database (Denmark)

    Petri, Helle; Vissing, John; Witting, Nanna; Bundgaard, Henning; Køber, Lars

    2012-01-01

    To estimate the degree of cardiac involvement regarding left ventricular ejection fraction, conduction abnormalities, arrhythmia, risk of sudden cardiac death (SCD) and the associations between cardiac involvement and cytosine-thymine-guanine (CTG)-repeat, neuromuscular involvement, age and gender...

  8. Optimization of Pumping System in Solar Pumped Laser.

    OpenAIRE

    Peng, Xu; Suhui, Yang; Changming, Zhao; Haiyang, Zhang; Yanlei, Qian; Jiayin, Hao; Tao, He; Wang, Huaxin

    2013-01-01

    The coupling between solar light radiation and laser rod medium in a solar pumped laser affects the efficiency of the laser. To optimize the pumping system, simulation of the two-stage pumping system with a Fresnel lens and conic pumping cavity is carried out with Tracepro software. According to the power density distribution along the axis at focal place of the Fresnel lens, the diameter and position of the pumping cavity window and the distance of the window from the Fresnel lens are optimi...

  9. VIRTUAL FUEL-PUMP DESIGN

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Some concepts of virtual product are discussed. The key technologies of virtual fuel-pump development are in detail analysed, which include virtual fuel-pump product modeling, intelligent simulation, distributed design environment, and virtual assembly. The virtual fuel-pump development prototype system considers requirement analysis, concept design, injection preferment analysis, detailed design, and assembly analysis.

  10. Antifibrinolytics in cardiac surgery

    Directory of Open Access Journals (Sweden)

    Achal Dhir

    2013-01-01

    Full Text Available Cardiac surgery exerts a significant strain on the blood bank services and is a model example in which a multi-modal blood-conservation strategy is recommended. Significant bleeding during cardiac surgery, enough to cause re-exploration and/or blood transfusion, increases morbidity and mortality. Hyper-fibrinolysis is one of the important contributors to increased bleeding. This knowledge has led to the use of anti-fibrinolytic agents especially in procedures performed under cardiopulmonary bypass. Nothing has been more controversial in recent times than the aprotinin controversy. Since the withdrawal of aprotinin from the world market, the choice of antifibrinolytic agents has been limited to lysine analogues either tranexamic acid (TA or epsilon amino caproic acid (EACA. While proponents of aprotinin still argue against its non-availability. Health Canada has approved its use, albeit under very strict regulations. Antifibrinolytic agents are not without side effects and act like double-edged swords, the stronger the anti-fibrinolytic activity, the more serious the side effects. Aprotinin is the strongest in reducing blood loss, blood transfusion, and possibly, return to the operating room after cardiac surgery. EACA is the least effective, while TA is somewhere in between. Additionally, aprotinin has been implicated in increased mortality and maximum side effects. TA has been shown to increase seizure activity, whereas, EACA seems to have the least side effects. Apparently, these agents do not differentiate between pathological and physiological fibrinolysis and prevent all forms of fibrinolysis leading to possible thrombotic side effects. It would seem prudent to select the right agent knowing its risk-benefit profile for a given patient, under the given circumstances.

  11. Utilization of eddy current flow meter for sodium flow measurement in FBRs

    International Nuclear Information System (INIS)

    Highlights: • Design and development of eddy current flow meters for FBRs have been carried out. • The developed flow meter was tested and calibrated in sodium. • The developed flow meter was used in FBTR reactor, India and in Phenix reactor, France. • The performance of the eddy current flow meter is found to be excellent. -- Abstract: Liquid metal cooled Fast Breeder Reactors form the second stage of Indian nuclear programme. Prototype Fast Breeder Reactor (PFBR) is 500MWe pool type reactor, which is under construction at Kalpakkam, India. Measurement of sodium flow in the reactor system is essential from both operational and safety point of view. Primary sodium pump discharge, secondary sodium circuit, safety grade decay heat removal circuit and auxiliary sodium circuits are the critical locations in an FBR, where sodium flow measurement is of importance. Apart from this, sodium flow measurement in subassemblies in the core facilitates the detection of flow blockage in the subassemblies. Permanent magnet flow meter is widely used for pipe flow measurement in sodium systems, however, it cannot be considered for applications like subassembly and pump discharge flow measurements. From the safety point of view, flow through the core should be ensured under all operating conditions in a FBR. Development of suitable flow sensors meeting the dimensional constraints and having accessibility for maintenance is a challenge. An eddy current flow meter was designed and developed for sodium flow measurement in PFBR and the developed probe was tested for its performance in a sodium test rig. The developed ECFM was also used for core flow measurements in Fast Breeder Test Reactor (FBTR), India and in Phenix reactor, France, during its end of life test before decommissioning. This paper discusses the activities related to the development, calibration, testing of ECFM probe for PFBR and results of its utilization for flow measurement in FBTR and in Phenix reactor, France

  12. Reaction, Transport and Settling Behavior of Lead-Bismuth Eutectic in Flowing Liquid Sodium

    International Nuclear Information System (INIS)

    The experimental study has been carried out to investigate reaction, transport and settling behavior of lead-bismuth eutectic (LBE) in flowing liquid sodium. In the test, 168 g of LBE were poured into flowing sodium from the top of a vertical-type sodium loop which contained 23.2 kg of sodium. The initial temperature of LBE and sodium was 673 K. The flow rate and the maximum velocity of sodium in the loop were controlled and measured at 20 dm3/min and 1 m/sec, respectively, using an electro-magnetic pump and an electro-magnetic flow meter. The sodium loop has a settling chamber at the lower part to investigate the concentration decrease behavior of solid particle reaction products in the sodium due to the settling effect. The concentration was measured by sodium sampling from the 11 positions of the loop during the experiment and its post-test chemical analysis. The temperature changes at the various parts of the loop were also measured during the experiment by thermo-couples attached on the outer surface of the loop. Ultrasonic detectors were attached on the outer surface of the loop below the position of a LBE pour nozzle to demonstrate the utility as a leak detector. (authors)

  13. Effect of dietary sodium on the Na-K ATPase inhibitor in patients with essential hypertension

    International Nuclear Information System (INIS)

    To study the circulating humoral factor modifying transmembrane sodium transport, plasma was obtained from 12 patients with essential hypertension (EH) fed a high sodium diet (NaCl 15 to 17 g/d) for seven days and thereafter a low sodium diet (NaCl 2 to 3 g/d) for seven days. Ouabain-sensitive 86Rb+ influx into the red blood cells (RBC) obtained from a healthy subject, and incubated with the plasma obtained during the high sodium diet was significantly lower than that incubated with the plasma obtained during the low sodium diet (3.74 +/- 0.26 v 3.97 +/- 0.30 nmol/10(8) cells, P less than .05). The changes in mean blood pressure from the high to low sodium diet showed a significant positive correlation with the changes in the ouabain-sensitive Rb influx into RBC in the plasma from the high to low sodium diet. These results suggest that a humoral factor modifying the sodium pump might be altered by sodium balance in EH, especially in salt-sensitive hypertension

  14. Trial fabrication and performance test of in-pile sodium loop for NSRR experiment

    International Nuclear Information System (INIS)

    Described are the details of trial in-pile sodium loop for the NSRR experiment and its performance test results. The loop can be inserted inside the experimental tube of the NSRR reactor, and consists of main four systems of sodium circulation, cover gas, evacuation and air cooling. Seven fuel pins in maximum can be accommodated in the test section, and the test section is surrounded by neutron modetator made of zirconium hydride to get higher thermal neutron flux, thereby higher energy deposition in a test fuel pin. The loop is a doubly contained loop to avoid sodium leakage to the experimental tube in case of the failure of the sodium circulation systems, and thermal insulation is made by evacuating the gas inside the secondary containment. The performance test was made successfully, and the design target values of sodium temperature of 5000C and sodium velocity of 8 m/sec were attained well stably and safely through the test, although the operation with high sodium velocity at low sodium temperature was rather difficult due to large heat generation by the operation of the electromagnetic pump. Furthermore, before filling the loop with sodium, trial cutting and welding at the test section were performed for exchange it after the in-pile experiment and the difficulties and problems of the work were understood. (author)

  15. Single ventricle cardiac defect

    International Nuclear Information System (INIS)

    Single ventricle heart is defined as a rare cardiac abnormality with a single ventricle chamber involving diverse functional and physiological defects. Our case is of a ten month-old baby boy who died shortly after admission to the hospital due to vomiting and diarrhoea. Autopsy findings revealed cyanosis of finger nails and ears. Internal examination revealed; large heart, weighing 60 grams, single ventricle, without a septum and upper membranous part. Single ventricle is a rare pathology, hence, this paper aims to discuss this case from a medico-legal point of view. (author)

  16. Measurement of atomic sodium in a premixed atmospheric flame by asynchronous optical sampling

    International Nuclear Information System (INIS)

    This paper presents a new combustion diagnostic suitable for measurements in turbulent, high- pressure flames. The authors demonstrate the efficacy of the method via measurements of atomic sodium in a laminar premixed flame at atmospheric pressure. The technique is a pump/rope method that overcomes many of the temporal problems inherent to that method. The method is then described

  17. Small Scroll Pump for Cryogenic Liquids Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The innovation is a compact, reliable, light weight, electrically driven pump capable of pumping cryogenic liquids, based on scroll pump technology. This pump will...

  18. Pumping characteristics of roots blower pumps for light element gases

    International Nuclear Information System (INIS)

    The pumping speed and compression ratio of the two-stage roots blower pumping system were measured for light element gases (H2, D2 and He) and for N2, in order to assess validity of the ITER torus roughing system as an ITER R and D task (T234). The pumping system of an Edwards EH1200 (nominal pumping speed of 1200 m3/s), two EH250s (ibid. 250 m3/s) and a backing pump (ibid. 100 m3/s) in series connection was tested under PNEUROP standards. The maximum pumping speeds of the two-stage system for D2 and N2 were 1200 and 1300 m3/h, respectively at 60 Hz, which satisfied the nominal pumping speed. These experimental data support the design validity of the ITER torus roughing system. (author)

  19. Development of an annular linear induction electromagnetic pump for the na-coolant circulation of LMFBR

    International Nuclear Information System (INIS)

    The EM (ElectroMagnetic) pump operated by Lorentz force (J x B) is developed for the sodium coolant circulation of LMFBR (Liquid Metal Fast Breeder Reactors). Design and experimental characterization are carried out on the linear induction EM pump of the narrow annular channel type. The pump which obtains propulsion force resultantly by the three phase symmetric alternating input currents is analyzed by the electrical equivalent circuit method used in the analyses of the induction machines. Then, the equivalent circuit for the pump consists of equivalent variables of primary and secondary resistances and magnetizing and leakage reactances given as functions of pump geometrical and electrical variables by Laithwaithe's standard formulae. Developing pressure-flowrate relation given by pump variables is sought from the balance equation on the circuit. Developing pressure and efficiency of the pump according to the pump variables are analyzed for the pump with a flowrate of 200 l/min. It is shown that pump is mainly characterized by length of the core, diameter of the inner core and channel gap geometrically and by input frequency electrically. Optimum values of pump geometrical and operational variables are determined to maximize the developing force and overall efficiency. The pump has geometrical size of 60 cm in length, 4.27 cm in inner core diameter and electrical input of 6,428 VA and 17 Hz. Optimally designed pump is manufactured by the consideration of material and operational requirements in the chemically-active sodium environment with high temperature of 600 .deg. C. Silicon-iron steel plates with high magnetic permeability in the high temperature are stacked for generation of the high magnetic flux and alumina-dispersion-strengthened-copper bands are used as exciting coils. Each turn of coil is insulated by asbestos band to protect electrical short in the high temperature. Stainless steel which can be compatible with sodium is selected as structural

  20. Bioinspired Artificial Sodium and Potassium Ion Channels.

    Science.gov (United States)

    Rodríguez-Vázquez, Nuria; Fuertes, Alberto; Amorín, Manuel; Granja, Juan R

    2016-01-01

    In Nature, all biological systems present a high level of compartmentalization in order to carry out a wide variety of functions in a very specific way. Hence, they need ways to be connected with the environment for communication, homeostasis equilibrium, nutrition, waste elimination, etc. The biological membranes carry out these functions; they consist of physical insulating barriers constituted mainly by phospholipids. These amphipathic molecules spontaneously aggregate in water to form bilayers in which the polar groups are exposed to the aqueous media while the non-polar chains self-organize by aggregating to each other to stay away from the aqueous media. The insulating properties of membranes are due to the formation of a hydrophobic bilayer covered at both sides by the hydrophilic phosphate groups. Thus, lipophilic molecules can permeate the membrane freely, while the small charged or very hydrophilic molecules require the assistance of other membrane components in order to overcome the energetic cost implied in crossing the non-polar region of the bilayer. Most of the large polar species (such as oligosaccharides, polypeptides or nucleic acids) cross into and out of the cell via endocytosis and exocytosis, respectively. Nature has created a series of systems (carriers and pores) in order to control the balance of small hydrophilic molecules and ions. The most important structures to achieve these goals are the ionophoric proteins that include the channel proteins, such as the sodium and potassium channels, and ionic transporters, including the sodium/potassium pumps or calcium/sodium exchangers among others. Inspired by these, scientists have created non-natural synthetic transporting structures to mimic the natural systems. The progress in the last years has been remarkable regarding the efficient transport of Na(+) and K(+) ions, despite the fact that the selectivity and the ON/OFF state of the non-natural systems remain a present and future challenge