WorldWideScience

Sample records for cardiac sodium pump

  1. Intracellular sodium affects ouabain interaction with the Na/K pump in cultured chick cardiac myocytes

    OpenAIRE

    1990-01-01

    Whether a given dose of ouabain will produce inotropic or toxic effects depends on factors that affect the apparent affinity (K0.5) of the Na/K pump for ouabain. To accurately resolve these factors, especially the effect of intracellular Na concentration (Nai), we have applied three complementary techniques for measuring the K0.5 for ouabain in cultured embryonic chick cardiac myocytes. Under control conditions with 5.4 mM Ko, the value of the K0.5 for ouabain was 20.6 +/- 1.2, 12.3 +/- 1.7, ...

  2. Cardiac sodium channelopathies

    NARCIS (Netherlands)

    A.S. Amin; A. Asghari-Roodsari; H.L. Tan

    2010-01-01

    Cardiac sodium channel are protein complexes that are expressed in the sarcolemma of cardiomyocytes to carry a large inward depolarizing current (I-Na) during phase 0 of the cardiac action potential. The importance of I-Na for normal cardiac electrical activity is reflected by the high incidence of

  3. Mechanical Blood Pumps for Cardiac Assistance

    Directory of Open Access Journals (Sweden)

    M. Akdis

    2005-01-01

    Full Text Available Cardiac assist devices are classified into the traditional engineering categories of displacement and rotary pumps. Clinical use and indications of the various pump categories are outlined and a detailed description of currently available systems is given. The first part deals with extracorporeal as well as implantable ventricular assist devices (VAD of the displacement type and is followed by a section on current developments in the field of total artificial hearts (TAH. The second part covers the rotary pump category from cardiopulmonary bypass applications to implantable systems, including specific design aspects of radial, diagonal, and axial pumps.

  4. Large sodium pump coastdown during an earthquake

    International Nuclear Information System (INIS)

    Analyses were performed to determine the responses of the main rotary element of a large sodium pump during the simultaneous occurrence of pump coastdown and a seismic event. Analytical procedures are described which enabled reduction of a multi-degree of freedom finite element model of the pump to a representative nonlinear single degree of freedom system with retention of acceptable computational accuracy. Pump rotor bearing impact forces and stresses, and the bearing rub forces which act throughout the pump coastdown were determined. Bearing material wear depth was calculated and an assessment was made of the effect of rub forces and the associated retarding torque on the shortening of pump coastdown time. Pump coastdown time can be very significantly shortened as a result of loss of rotor bearing stiffness and rubbing at the lower rotor speeds

  5. Mechanical Blood Pumps for Cardiac Assistance

    OpenAIRE

    Akdis, M; Reul, H

    2005-01-01

    Cardiac assist devices are classified into the traditional engineering categories of displacement and rotary pumps. Clinical use and indications of the various pump categories are outlined and a detailed description of currently available systems is given. The first part deals with extracorporeal as well as implantable ventricular assist devices (VAD) of the displacement type and is followed by a section on current developments in the field of total artificial hearts (TAH). The second part co...

  6. Na/K pump regulation of cardiac repolarization: insights from a systems biology approach

    KAUST Repository

    Bueno-Orovio, Alfonso

    2013-05-15

    The sodium-potassium pump is widely recognized as the principal mechanism for active ion transport across the cellular membrane of cardiac tissue, being responsible for the creation and maintenance of the transarcolemmal sodium and potassium gradients, crucial for cardiac cell electrophysiology. Importantly, sodium-potassium pump activity is impaired in a number of major diseased conditions, including ischemia and heart failure. However, its subtle ways of action on cardiac electrophysiology, both directly through its electrogenic nature and indirectly via the regulation of cell homeostasis, make it hard to predict the electrophysiological consequences of reduced sodium-potassium pump activity in cardiac repolarization. In this review, we discuss how recent studies adopting the systems biology approach, through the integration of experimental and modeling methodologies, have identified the sodium-potassium pump as one of the most important ionic mechanisms in regulating key properties of cardiac repolarization and its rate dependence, from subcellular to whole organ levels. These include the role of the pump in the biphasic modulation of cellular repolarization and refractoriness, the rate control of intracellular sodium and calcium dynamics and therefore of the adaptation of repolarization to changes in heart rate, as well as its importance in regulating pro-arrhythmic substrates through modulation of dispersion of repolarization and restitution. Theoretical findings are consistent across a variety of cell types and species including human, and widely in agreement with experimental findings. The novel insights and hypotheses on the role of the pump in cardiac electrophysiology obtained through this integrative approach could eventually lead to novel therapeutic and diagnostic strategies. © 2013 Springer-Verlag Berlin Heidelberg.

  7. Sodium Channel (Dys)Function and Cardiac Arrhythmias

    NARCIS (Netherlands)

    C.A. Remme; C.R. Bezzina

    2010-01-01

    P>Cardiac voltage-gated sodium channels are transmembrane proteins located in the cell membrane of cardiomyocytes. Influx of sodium ions through these ion channels is responsible for the initial fast upstroke of the cardiac action potential. This inward sodium current thus triggers the initiation an

  8. Genetic and environmental factors in cardiac sodium channel disease

    NARCIS (Netherlands)

    Y. Mizusawa

    2016-01-01

    Cardiac sodium channelopathies, such as long QT syndrome type3 (LQT3), Brugada syndrome (BrS) and cardiac conduction disease (CCD), are heritable diseases associated with mutations in the SCN5A gene and sudden cardiac death. They were classically thought to be a monogenic disease. However, while LQT

  9. Sodium pump organization in dendritic spines.

    Science.gov (United States)

    Blom, Hans; Bernhem, Kristoffer; Brismar, Hjalmar

    2016-10-01

    Advancement in fluorescence imaging with the invention of several super-resolution microscopy modalities (e.g., PALM/STORM and STED) has opened up the possibility of deciphering molecular distributions on the nanoscale. In our quest to better elucidate postsynaptic protein distribution in dendritic spines, we have applied these nanoscopy methods, where generated results could help improve our understanding of neuronal functions. In particular, we have investigated the principal energy transformer in the brain, i.e., the [Formula: see text]-ATPase (or sodium pump), an essential protein responsible for maintaining resting membrane potential and a major controller of intracellular ion homeostasis. In these investigations, we have focused on estimates of protein amount, giving assessments of how variations may depend on labeling strategies, sample analysis, and choice of nanoscopic imaging method, concluding that all can be critical factors for quantification. We present a comparison of these results and discuss the influences this may have for homeostatic sodium regulation in neurons and energy consumption. PMID:27175374

  10. The Performance test of Mechanical Sodium Pump with Water Environment

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Chungho; Kim, Jong-Man; Ko, Yung Joo; Jeong, Ji-Young; Kim, Jong-Bum [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Ko, Bock Seong; Park, Sang Jun; Lee, Yoon Sang [SAM JIN Industrial Co. LTD., Chunan (Korea, Republic of)

    2015-10-15

    As contrasted with PWR(Pressurized light Water Reactor) using water as a coolant, sodium is used as a coolant in SFR because of its low melting temperature, high thermal conductivity, the high boiling temperature allowing the reactors to operate at ambient pressure, and low neutron absorption cross section which is required to achieve a high neutron flux. But, sodium is violently reactive with water or oxygen like the other alkali metal. So Very strict requirements are demanded to design and fabricate of sodium experimental facilities. Furthermore, performance testing in high temperature sodium environments is more expensive and time consuming and need an extra precautions because operating and maintaining of sodium experimental facilities are very difficult. The present paper describes performance test results of mechanical sodium pump with water which has been performed with some design changes using water test facility in SAM JIN Industrial Co. To compare the hydraulic characteristic of model pump with water and sodium, the performance test of model pump were performed using vender's experimental facility for mechanical sodium pump. To accommodate non-uniform thermal expansion and to secure the operability and the safety, the gap size of some parts of original model pump was modified. Performance tests of modified mechanical sodium pump with water were successfully performed. Water is therefore often selected as a surrogate test fluid because it is not only cheap, easily available and easy to handle but also its important hydraulic properties (density and kinematic viscosity) are very similar to that of the sodium. Normal practice to thoroughly test a design or component before applied or installed in reactor is important to ensure the safety and operability in the sodium-cooled fast reactor (SFR). So, in order to estimate the hydraulic behavior of the PHTS pump of DSFR (600 MWe Demonstraion SFR), the performance tests of the model pump such as performance

  11. A sodium-channel mutation causes isolated cardiac conduction disease

    NARCIS (Netherlands)

    Tan, HL; Bink-Boelkens, MTE; Bezzina, CR; Viswanathan, PC; Beaufort-Krol, GCM; van Tintelen, PJ; van den Berg, MP; Wilde, AAM; Balser, [No Value

    2001-01-01

    Cardiac conduction disorders slow the heart rhythm and cause disability in millions of people worldwide. Inherited mutations in SCN5A, the gene encoding the human cardiac sodium (Na+) channel, have been associated with rapid heart rhythms that occur suddenly and are life-threatening(1-3); however, a

  12. Designing & Optimizing a Moving Magnet Pump for Liquid Sodium Systems

    Science.gov (United States)

    Hvasta, Michael G.

    Advanced materials such as NF-616, NF-709, HT-UPS, and silicon carbide (SiC) have greater strength than traditional structural materials such as 316-SS. Thus, using these high-strength materials to build sodium-cooled fast reactors (SFRs) could potentially reduce construction costs by lessening the required amount of material, and increase the efficiency of electromagnetic pumps by limiting ohmic heating within the pump duct walls. However, information pertaining to the sodium-compatibility of these alloys and ceramics is very sparse. Therefore, two separate test facilities were built to study the impact of both static and dynamic sodium corrosion The dynamic test facility enabled sodium corrosion to be studied under prototypic SFR operating conditions (T = 500 [C], V = 9.35 [m/s], CO = 2-3 [wppm]). The oxygen concentration, CO, within the dynamic test facility was maintained using a cold trap and measured with a plugging meter. The flow rate of the sodium was measured using a calibrated electromagnetic flowmeter. A moving magnet pump (MMP) was used to move the liquid sodium past the corrosion samples at a high velocity. Using newly developed theory, it was found that MMP performance could be accurately modeled and predicted for a wide variety of pump configurations.

  13. Cardiac Bypass Pump Flow Management via NIRS Monitoring

    OpenAIRE

    Macnab, Andrew J.; Gagnon, Roy E.; Gagnon, Faith A.; Blackstock, Derek; LeBlanc, Jacques G.

    2003-01-01

    During cardiac surgery, bypass pumps rely on pressure monitors to evaluate flow. We studied whether it would be possible to optimize pump flow by monitoring changes in cerebral cytochrome a,a3 using NIRS to maintain cyt redox status at its pre-bypass level. Method: 18 healthy 7–45 kg swine were placed on bypass for repeated cycles of cooling and re-warming from 36 to 15 to 36°C in 3°C steps. Between each cycle, the swine's bypass pump blood flow rate was adjusted to restore cytochrome redox s...

  14. The inhibitory effect of phospholemman on the sodium pump requires its palmitoylation.

    Science.gov (United States)

    Tulloch, Lindsay B; Howie, Jacqueline; Wypijewski, Krzysztof J; Wilson, Catherine R; Bernard, William G; Shattock, Michael J; Fuller, William

    2011-10-14

    Phospholemman (PLM), the principal sarcolemmal substrate for protein kinases A and C in the heart, regulates the cardiac sodium pump. We investigated post-translational modifications of PLM additional to phosphorylation in adult rat ventricular myocytes (ARVM). LC-MS/MS of tryptically digested PLM immunoprecipitated from ARVM identified cysteine 40 as palmitoylated in some peptides, but no information was obtained regarding the palmitoylation status of cysteine 42. PLM palmitoylation was confirmed by immunoprecipitating PLM from ARVM loaded with [(3)H]palmitic acid and immunoblotting following streptavidin affinity purification from ARVM lysates subjected to fatty acyl biotin exchange. Mutagenesis identified both Cys-40 and Cys-42 of PLM as palmitoylated. Phosphorylation of PLM at serine 68 by PKA in ARVM or transiently transfected HEK cells increased its palmitoylation, but PKA activation did not increase the palmitoylation of S68A PLM-YFP in HEK cells. Wild type and unpalmitoylatable PLM-YFP were all correctly targeted to the cell surface membrane, but the half-life of unpalmitoylatable PLM was reduced compared with wild type. In cells stably expressing inducible PLM, PLM expression inhibited the sodium pump, but PLM did not inhibit the sodium pump when palmitoylation was inhibited. Hence, palmitoylation of PLM controls its turnover, and palmitoylated PLM inhibits the sodium pump. Surprisingly, phosphorylation of PLM enhances its palmitoylation, probably through the enhanced mobility of the phosphorylated intracellular domain increasing the accessibility of cysteines for the palmitoylating enzyme, with interesting theoretical implications. All FXYD proteins have conserved intracellular cysteines, so FXYD protein palmitoylation may be a universal means to regulate the sodium pump.

  15. Role of Sodium Channel on Cardiac Action Potential

    Directory of Open Access Journals (Sweden)

    S. H. Sabzpoushan

    2012-06-01

    Full Text Available Sudden cardiac death is a major cause of death worldwide. In most cases, it's caused by abnormal action potential propagation that leads to cardiac arrhythmia. The aim of this article is to study the abnormal action potential propagation through sodium ion concentration variations. We use a new electrophysiological model that is both detailed and computationally efficient. This efficient model is based on the partial differential equation method. The central finite difference method is used for numerical solving of the two-dimensional (2D wave propagation equation. Simulations are implemented in two stages, as a single cardiac cell and as a two-dimensional grid of cells. In both stages, the normal action potential formation in case of a single cell and it's normal propagation in case of a two-dimensional grid of cells were simulated with nominal sodium ion conductance. Then, the effect of sodium ion concentration on the action potential signal was studied by reducing the sodium ion conductance. It is concluded that reducing the sodium ion conductance, decreases both passing ability and conduction velocity of the action potential wave front.

  16. OUABAIN AND INSULIN INDUCE SODIUM PUMP ENDOCYTOSIS IN RENAL EPITHELIUM

    OpenAIRE

    Gupta, Shalini; Yan, Yanling; Malhotra, Deepak; Liu, Jiang; Xie, Zijian; Najjar, Sonia M.; Shapiro, Joseph I

    2012-01-01

    Cardiotonic steroids signaling through the basolateral sodium pump (Na/KATPase) have been shown to alter renal salt handling in intact animals. As the relationship between renal salt handling and blood pressure is a key determinant of hypertension, and patients with insulin resistance are frequently hypertensive, we chose to examine whether there might be competition for resources necessary for receptor mediated endocytosis.

  17. Nonlinear seismic analysis of a large sodium pump

    International Nuclear Information System (INIS)

    The bearings and seismic bumpers used in a large sodium pump of a typical breeder reactor plant may need to be characterized by nonlinear springs and gaps. Then, nonlinear seismic analysis utilizing the time-history method is an effective way to predict the pump behaviors during seismic events, especially at those bearing and seismic bumper areas. In this study, synthesized time histories were developed based on specified seismic response spectra. A nonlinear seismic analysis was then conducted and results were compared with those obtained by linear seismic analysis using the response spectrum method. In contrast to some previous nonlinear analysis trends, the bearing impact forces predicted by nonlinear analysis were higher than those obtained by the response spectrum method. This might be due to the larger gaps and stiffer bearing supports used in this specific pump. However, at locations distant from the impact source, the nonlinear seismic analysis has predicted slightly less responses than those obtained by linear seismic analysis. The seismically induced bearing impact forces were used to study the friction induced thermal stresses on the hydrostatic bearing and to predict the coastdown time of the pump. Results and discussions are presented

  18. The Start-up Test of Mechanical Sodium Pump installed in STELLA-1

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Chungho; Kim, Jong-Man; Ko, Yung Joo; Kim, Byeongyeon; Cho, Youngil; Jung, Min-Hwan; Gam, Da-Young; Lee, Yong Bum; Jeong, Ji-Young; Kim, Jong-Bum [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    Testing at the high temperature sodium environments is more expensive and time consuming because of difficulties of operating and maintaining of sodium experimental facilities. Consequent upon those problems, water is often selected as a surrogate test fluid because its important hydraulic properties such as a density and a kinematic viscosity are not only very similar to that of the sodium but also it is cheap, easily available and easy to handle. SFR NSSS System Design Division of Korea Atomic Energy Research Institute (KAERI) is performing a development and demonstration of sodium technology using various sodium experimental facilities, especially STELLA-1. STELLA-1 (Sodium inTegral Effect test Loop for safety simuLation and Assessment) is a large-scale separated effect test facility for demonstrating the thermal-hydraulic performances of major components such as a Sodium-to-Sodium heat exchanger (DHX), Sodium-to-Air heat exchanger (AHX) of the decay heat removal system, and mechanical sodium pump of the primary heat transport system (PHTS). The result of start-up test, most of the instruments and components except for flow control valve are functionally work. Also, we confirmed that performance test of mechanical sodium pump is unable at the high flow rate with lower RPM because pressure drops of pump performance test loop are bigger than the pump head of some cases. To confirm the safety and operability of major components in the sodium-cooled fast reactor (SFR), demonstration of component performance should be carried out before its installation in reactor. So, in order to estimate the hydraulic behavior of the mechanical sodium pump, the performance tests of the model pump with water environment was carried out using a pump vender's experimental facility. Also, to compare the hydraulic characteristic of model pump with water and sodium, the performance test of model pump with sodium environment were performed using STELLA-1. The present paper describes

  19. Chemical radiation protection of sodium pump in mammalian skeletal muscle

    International Nuclear Information System (INIS)

    When male albino rats of the Wistar strain received wholebody gamma irradiation at a dose level of 8.5 Gy, 22N outward movement from the diaphragm muscle fibres slowed down, while its uptake was enhanced. When imidazole was intraperitoneally injected prior to irradiation both movements returned nearly to normal rates. Experiments carried out on the 7th day post irradiation, indicated that gamma irradiation had exerted some sort of damage upon the sodium pumping mechanism in mammalian skeletal muscle, and that imidazole injection prior to radiation exposure exerted a remarkable radioprotective effect on those vital biophysical processes. The results have been discussed in view of the relevant literature. (author)

  20. Mechanisms of pulmonary dysfunction after on-pump and off-pump cardiac surgery: a prospective cohort study

    OpenAIRE

    Jansen Evert K; Groeneveld AB Johan; Verheij Joanne

    2007-01-01

    Abstract Background Pulmonary dysfunction following cardiac surgery is believed to be caused, at least in part, by a lung vascular injury and/or atelectasis following cardiopulmonary bypass (CPB) perfusion and collapse of non-ventilated lungs. Methods To test this hypothesis, we studied the postoperative pulmonary leak index (PLI) for 67Ga-transferrin and (transpulmonary) extravascular lung water (EVLW) in consecutive patients undergoing on-pump (n = 31) and off-pump (n = 8) cardiac surgery. ...

  1. Sodium testing of intermediate-size inducer pump in SPTF at ETEC

    International Nuclear Information System (INIS)

    The overall test program includes pump assembly, installation, testing, removal from the test loop, disassembly and final inspection of the entire pump. Testing will include checkout tests, head/flow and efficiency characterizations at selected speeds and sodium temperatures, suction performance determination, a 2000 hour endurance test, and thermal transient tests. The pump will be cleaned of sodium, disassembled, and examined before the 2000 hour endurance test and after the thermal transient tests to determine the effects that long-term operation at 200 percent NPSH margin has on the pump components. The testing will be done at Energy Technology Engineering Center (ETEC). Assembly, sodium removal, disassembly, and initial inspection will be performed at Component Handling and Cleaning Facility (CHCF) and sodium testing will be done at Sodium Pump Test Facility

  2. Specialists' meeting on cavitation criteria for designing mechanisms working in sodium: Application to pumps. Summary report

    International Nuclear Information System (INIS)

    The purpose of the meeting was to provide a forum for discussions and exchanges of views on cavitation phenomena in sodium, cavitation tests on pump models in water and sodium, application of test results to LMFBR plants, impact on sodium pump design. Topics of interest were also detection methods for cavitation during tests and cavitation problems in electro-magnetic pumps. Two categories of papers were presented: national position papers and specialised topical papers. The main topics discussed, in three sessions were the following: National papers on cavitation; cavitation tests, performance, measuring methods and results; application of test results and implications on the future programmes

  3. Sodium testing of intermediate-size inducer pump in SPTF at ETEC

    International Nuclear Information System (INIS)

    The overall test program includes pump assembly, installation, testing, removal from the test loop, disassembly and final inspection of the entire pump. Testing will include checkout tests, head/flow and efficiency characterizations at selected speeds and sodium temperatures, suction performance determination, a 2000 hour design point endurance test, a 300 hour off design endurance test, and thermal transient tests. The pump will be cleaned of sodium, disassembled, and examined before the 2000 hour endurance test and after the thermal transient tests to determine the effects that long-term operation at 200 percent NPSH margin and off design operation at the same flow and NPSH have on the pump components

  4. Centrifugal pump and roller pump in adult cardiac surgery: a meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Saczkowski, Richard; Maklin, Michelle; Mesana, Thierry; Boodhwani, Munir; Ruel, Marc

    2012-08-01

    Centrifugal pump (CP) and roller pump (RP) designs are the dominant main arterial pumps used in cardiopulmonary bypass (CPB). Trials reporting clinical outcome measures comparing CP and RP are controversial. Therefore, a meta-analysis was undertaken to evaluate clinical variables from randomized controlled trials (RCTs). Keyword searches were performed on Medline (1966-2011), EmBase (1980-2011), and CINAHL (1981-2011) for studies comparing RP and CP as the main arterial pump in adult CPB. Pooled fixed-effects estimates for dichotomous and continuous data were calculated as an odds ratio and weighted-mean difference, respectively. The P value was utilized to assess statistical significance (P pump-related malfunction or mishap. The meta-analysis of RCTs comparing CP and RP in adult cardiac surgery suggests no significant difference for hematological variables, postoperative blood loss, transfusions, neurological outcomes, or mortality.

  5. Mechanisms of pulmonary dysfunction after on-pump and off-pump cardiac surgery: a prospective cohort study

    Directory of Open Access Journals (Sweden)

    Jansen Evert K

    2007-02-01

    Full Text Available Abstract Background Pulmonary dysfunction following cardiac surgery is believed to be caused, at least in part, by a lung vascular injury and/or atelectasis following cardiopulmonary bypass (CPB perfusion and collapse of non-ventilated lungs. Methods To test this hypothesis, we studied the postoperative pulmonary leak index (PLI for 67Ga-transferrin and (transpulmonary extravascular lung water (EVLW in consecutive patients undergoing on-pump (n = 31 and off-pump (n = 8 cardiac surgery. We also studied transfusion history, radiographs, ventilatory and gas exchange variables. Results The postoperative PLI and EVLW were elevated above normal in 42 and 29% after on-pump surgery and 63 and 37% after off-pump surgery, respectively (ns. Transfusion of red blood cell (RBC concentrates, PLI, EVLW, occurrence of atelectasis, ventilatory variables and duration of mechanical ventilation did not differ between groups, whereas patients with atelectasis had higher venous admixture and airway pressures than patients without atelectasis (P = 0.037 and 0.049. The PLI related to number of RBC concentrates infused (P = 0.025. Conclusion The lung vascular injury in about half of patients after cardiac surgery is not caused by CPB perfusion but by trauma necessitating RBC transfusion, so that off-pump surgery may not afford a benefit in this respect. However, atelectasis rather than lung vascular injury is a major determinant of postoperative pulmonary dysfunction, irrespective of CPB perfusion.

  6. Development of a sodium-pump/neon-lasant photopumped soft X-ray laser

    International Nuclear Information System (INIS)

    Resonant photopumping of heliumlike neon by heliumlike sodium is investigated to extend this potentially efficient technique for inversion and lasing to shorter wavelengths. Properties of the sodium-pump plasma and the neon-lasant plasma required to optimize fluorescence and lasing are determined. The implosion of a sodium-bearing plasma with a megampere pulsed-power driver (Gamble II) is used to produce a linear Z-pinch with up to 25 GW of sodium-pump-line radiation. A separate neon plasma, driven by part of the return current form the imploding sodium plasma, is created parallel to the sodium line source at a distance of 5 cm. Implosion requirements for the neon plasma and its dynamics in the Gamble II return-current geometry are described. Evidence for population inversion is indicated by fluorescence enhancement of the 11-A resonance line from the n = 4 level of neon when pumped by sodium. The neon spectra are in qualitative agreement with calculations based on the sodium-pump power. Improvements in the experiment required to achieve lasing are discussed

  7. From Syncitium to Regulated Pump: A Cardiac Muscle Cellular Update

    Science.gov (United States)

    Korzick, Donna H.

    2011-01-01

    The primary purpose of this article is to present a basic overview of some key teaching concepts that should be considered for inclusion in an six- to eight-lecture introductory block on the regulation of cardiac performance for graduate students. Within the context of cardiac excitation-contraction coupling, this review incorporates information…

  8. Palytoxin induces K+ efflux from yeast cells expressing the mammalian sodium pump.

    Science.gov (United States)

    Scheiner-Bobis, G; Meyer zu Heringdorf, D; Christ, M; Habermann, E

    1994-06-01

    Palytoxin causes potassium efflux and sodium influx in all investigated animals cells. Much evidence points to the sodium pump (Na+/K(+)-ATPase) as the target of the toxin. A heterologous expression system for mammalian Na+/K(+)-ATPase in the brewers yeast Saccharomyces cerevisiae has been used to test this hypothesis. Yeast cells do not contain endogenous sodium pumps but can be transformed with vectors coding for the alpha and beta subunits of the mammalian sodium pump. We now show that transformed yeast cells expressing both alpha and beta subunits of Na+/K(+)-ATPase are highly sensitive to the toxin, as measured by the loss of intracellular potassium. Palytoxin-induced potassium efflux is completely inhibited by 500 microM ouabain. In contrast, nontransformed yeast cells or cells expressing either the alpha or beta subunits are insensitive to palytoxin. Thus, the alpha/beta heterodimer of the sodium pump is required for the release of potassium induced by palytoxin. The results suggest that palytoxin converts the sodium pump into an open channel, allowing the passage of alkali ions.

  9. Increasing cardiac output and decreasing oxygenation sequence in pump twins of acardiac twin pregnancies

    International Nuclear Information System (INIS)

    An acardiac twin pregnancy is a rare but serious complication of monochorionic twinning and consists of an acardiac twin and a pump twin. The acardiac twin is a severely malformed fetus that lacks most organs, particularly a heart, but grows during pregnancy because it is perfused by the developmentally normal pump twin via a set of arterioarterial and venovenous placental anastomoses. Pump twins die intrauterine or neonatally in about 50% of the cases. Because the effects of an acardiac mass on the pump twin's development are incompletely known, methods for outcome prognosis are currently not available. We sought to derive simple relations for the pump twin's excess cardiac output and decreased oxygenation and to use available clinical cases for a preliminary test of the model. As a method, we used a theoretical flow model to represent the fetoplacental circulation of an acardiac twin pregnancy and estimated blood deoxygenation and reoxygenation following perfusion of the two bodies and placentas, respectively. The results show the pump twin's excess cardiac output and decrease of venous oxygen saturation to depend on the ratio of pump twin to acardiac twin umbilical blood flow, whose ratio can be measured by ultrasonography. The clinical cases show a decreasing umbilical flow ratio with gestation. In conclusion, prospective serial study is necessary to test whether measurement of umbilical flow ratios allows monitoring the pump twin's pathophysiologic development, possibly resulting in a guideline for prognosis of pump twin survival. (note)

  10. Increasing cardiac output and decreasing oxygenation sequence in pump twins of acardiac twin pregnancies

    Energy Technology Data Exchange (ETDEWEB)

    Gemert, Martin J C van [Laser Center and Department of Obstetrics and Gynecology, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam (Netherlands); Umur, Asli [Laser Center and Department of Obstetrics and Gynecology, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam (Netherlands); Wijngaard, Jeroen P H M van den [Laser Center and Department of Obstetrics and Gynecology, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam (Netherlands); VanBavel, Ed [Department of Medical Physics, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands); Vandenbussche, Frank P H A [Department of Obstetrics, Leiden University Medical Center, Leiden (Netherlands); Nikkels, Peter G J [Department of Pathology, University Medical Center, Utrecht (Netherlands)

    2005-02-07

    An acardiac twin pregnancy is a rare but serious complication of monochorionic twinning and consists of an acardiac twin and a pump twin. The acardiac twin is a severely malformed fetus that lacks most organs, particularly a heart, but grows during pregnancy because it is perfused by the developmentally normal pump twin via a set of arterioarterial and venovenous placental anastomoses. Pump twins die intrauterine or neonatally in about 50% of the cases. Because the effects of an acardiac mass on the pump twin's development are incompletely known, methods for outcome prognosis are currently not available. We sought to derive simple relations for the pump twin's excess cardiac output and decreased oxygenation and to use available clinical cases for a preliminary test of the model. As a method, we used a theoretical flow model to represent the fetoplacental circulation of an acardiac twin pregnancy and estimated blood deoxygenation and reoxygenation following perfusion of the two bodies and placentas, respectively. The results show the pump twin's excess cardiac output and decrease of venous oxygen saturation to depend on the ratio of pump twin to acardiac twin umbilical blood flow, whose ratio can be measured by ultrasonography. The clinical cases show a decreasing umbilical flow ratio with gestation. In conclusion, prospective serial study is necessary to test whether measurement of umbilical flow ratios allows monitoring the pump twin's pathophysiologic development, possibly resulting in a guideline for prognosis of pump twin survival. (note)

  11. SODIUM BICARBONATE INFUSION: TO PREVENT CARDIAC SURGERY - ASSOCIATED ACUTE KIDNEY INJURY

    Directory of Open Access Journals (Sweden)

    Ramesh

    2015-02-01

    Full Text Available OBJECTIVES: The incidence of cardiac surgery – associated acute kidney injury is 50% of patients and is associated with increased mortality and morbidity. This study aimed to determine if perioperative urinary and plasma alkalization with sodium bicarbonate infusion re duces the incidence of cardiac surgery – associated acute kidney injury. SETTING AND DESIGN: This study is double blind randomized control trial conducted at U N Mehta Institute of Cardiology and Research Center , India. METHOD S AND RESULT: A total of 140 pat ients scheduled to undergo elective cardiac surgery , who were at increased risk of development of cardiac surgery – associated acute kidney injury using recognized risk factors. Patients were randomly allocated to receive either sodium bicarbonate (n = 70 o r sodium chloride (n = 70 infusion , commencing at the start of anesthesia , in a dose of 4 mmol/kg over 24 hour. The primary outcome measure was the number of patients with development of CSA - AKI , defined as an increase in creatinine greater than 25% from baseline to peak value within the first three postoperative days. Significant differences among the groups in both plasma and urinary pH were achieved 6 hours after commencement of the infusion , and these changes persisted for more than 24 hours. A total o f 7 out of 70(10% patients in the sodium bicarbonate group and 16 out of 70(22.85% patients in the sodium chloride group developed acute kidney injury within the first three postoperative days with p value of 0.06 which is statistically not significant . There were also no significant differences in ventilation hours , ICU or hospital length of stay , or mortality. CONCLUSIONS: Perioperative alkalization of blood and urine using an infusion of sodium bicarbonate did not result in a decrease in the incidence of acute kidney injury in patients undergoing cardiac surgery. KEYWORDS: Acute kidney injury; Cardiac surgery; Cardiopulmonary bypass; Creatinine

  12. Crystal structure of the sodium-potassium pump

    DEFF Research Database (Denmark)

    Morth, J Preben; Pedersen, Bjørn Panyella; Toustrup-Jensen, Mads S;

    2007-01-01

    The Na+,K+-ATPase generates electrochemical gradients for sodium and potassium that are vital to animal cells, exchanging three sodium ions for two potassium ions across the plasma membrane during each cycle of ATP hydrolysis. Here we present the X-ray crystal structure at 3.5 A resolution of the...

  13. Development of active magnetic bearings and ferrofluid seals toward oil free sodium pumps

    Energy Technology Data Exchange (ETDEWEB)

    Sreedhar, B.K., E-mail: bksd@igcar.gov.in; Kumar, R. Nirmal; Sharma, Prashant; Ruhela, Shivprakash; Philip, John; Sundarraj, S.I.; Chakraborty, N.; Mohana, M.; Sharma, Vijay; Padmakumar, G.; Nashine, B.K.; Rajan, K.K.

    2013-12-15

    Sodium centrifugal pumps employ conventional oil cooled bearings and mechanical seals to support the rotor assembly outside sodium and to seal the cover gas from the atmosphere. Although engineered safety features are incorporated in the design and detailed operational procedures formulated to ensure that no oil contamination of sodium can occur, there have been incidents of oil ingress into sodium. A design variant that eliminates the need for oil in top bearings and seals is therefore a promising option. This paper discusses the work in progress to develop a magnetic bearing and ferrofluid seal combination that can achieve this purpose.

  14. A novel LQT3 mutation implicates the human cardiac sodium channel domain IVS6 in inactivation kinetics

    NARCIS (Netherlands)

    Groenewegen, WA; Bezzina, CR; van Tintelen, JP; Hoorntje, TM; Mannens, MMAM; Wilde, AAM; Jongsma, HJ; Rook, MB

    2003-01-01

    The Long QT3 syndrome is associated with mutations in the cardiac sodium channel gene SCN5A. Objective: The aim of the present study was the identification and functional characterization of a mutation in a family with the long QT3 syndrome. Methods: The human cardiac sodium channel gene SCN5A was s

  15. Structure of the light-driven sodium pump KR2 and its implications for optogenetics.

    Science.gov (United States)

    Gushchin, Ivan; Shevchenko, Vitaly; Polovinkin, Vitaly; Borshchevskiy, Valentin; Buslaev, Pavel; Bamberg, Ernst; Gordeliy, Valentin

    2016-04-01

    A key and common process present in organisms from all domains of life is the maintenance of the ion gradient between the inside and the outside of the cell. The gradient is generated by various active transporters, among which are the light-driven ion pumps of the microbial rhodopsin family. Whereas the proton-pumping and anion-pumping rhodopsins have been known for a long time, the cation (sodium) pumps were described only recently. Following the discovery, high-resolution atomic structures of the pump KR2 were determined that revealed the complete ion translocation pathway, including the positions of the characteristic Asn-Asp-Gln (NDQ) triad, the unusual ion uptake cavity acting as a selectivity filter, the unique N-terminal α-helix, capping the ion release cavity, and unexpected flexibility of the retinal-binding pocket. The structures also revealed pentamerization of KR2 and binding of sodium ions at the interface. Finally, on the basis of the structures, potassium-pumping KR2 variants have been designed, making the findings even more important for optogenetic applications. In this Structural Snapshot, we analyse the implications of the structural findings for understanding the sodium translocation mechanism and application of the pump and its mutants in optogenetics. PMID:26535564

  16. Rotor dynamic studies of a vertical sodium pump supported on a spherical seat

    International Nuclear Information System (INIS)

    One of the important areas in the mechanical design of Primary Sodium Pumps (PSP) concerns with the problem of accommodating the differential thermal expansion between the pump support and the discharge pipe which function at substantially different temperatures. A spherical ball resting on a spherical split seat is designed to allow the tilting of the pump without creating significant stresses in the pump casing and the discharge pipe. To ascertain the dynamic performance of the pump and to validate the design, an experimental study was carried out with a 1/4 model spherical seat installed in an existing 50 cu.m/hr pump. The paper discusses the modeling criteria, details of theoretical/experimental studies and results obtained during testing. This paper also discusses details of full size test rig which is under construction. (author). 4 refs., 3 figs., 2 tabs

  17. Phenotypical Manifestations of Mutations in the Genes Encoding Subunits of the Cardiac Sodium Channel

    NARCIS (Netherlands)

    Wilde, Arthur A. M.; Brugada, Ramon

    2011-01-01

    Variations in the gene encoding for the major sodium channel (Na(v)1.5) in the heart, SCN5A, has been shown to cause a number of arrhythmia syndromes (with or without structural changes in the myocardium), including the long-QT syndrome (type 3), Brugada syndrome, (progressive) cardiac conduction di

  18. Temporal Analysis of Valence & Electrostatics in Ion-Motive Sodium Pump

    OpenAIRE

    J. Fonseca; Kaya, S.; Guennoun, S.; Rakowski, R.

    2007-01-01

    The present work establishes a unique framework for the simulation study of ion-motive pumps in general and the Na+/K+-ATPase, or sodium pump, in particular. We shall discuss the implications of electrostatic analysis, valence calculations, and protein cavity data, each carried over data extracted from molecular dynamics simulations, on the structure-function relationship of Na+/K+-ATPase. These diverse set of tools will be used to investigate atomic-level characteristics that remain undeterm...

  19. Inherited Cardiac Diseases Caused by Mutations in the Nav1.5 Sodium Channel

    DEFF Research Database (Denmark)

    Tfelt-Hansen, Jacob; Winkel, Bo Gregers; Grunnet, Morten;

    2009-01-01

    Cardiac Diseases Caused by SCN5A Mutations. A prerequisite for a normal cardiac function is a proper generation and propagation of electrical impulses. Contraction of the heart is obtained through a delicate matched transmission of the electrical impulses. A pivotal element of the impulse...... propagation is the depolarizing sodium current, responsible for the initial depolarization of the cardiomyocytes. Recent research has shown that mutations in the SCN5A gene, encoding the cardiac sodium channel Nav1.5, are associated with both rare forms of ventricular arrhythmia, as well as the most frequent...... form of arrhythmia, atrial fibrillation (AF). In this comprehensive review, we describe the functional role of Nav1.5 and its associated proteins in propagation and depolarization both in a normal- and in a pathophysiological setting. Furthermore, several of the arrhythmogenic diseases, such as long...

  20. Two functionally different Na/K pumps in cardiac ventricular myocytes

    OpenAIRE

    1995-01-01

    The whole-cell patch-clamp technique was used to voltage clamp acutely isolated myocytes at -60 mV and study effects of ionic environment on Na/K pump activity. In quiescent guinea pig myocytes, normal intracellular Na+ is approximately 6 mM, which gives a total pump current of 0.25 +/- 0.09 pA/pF, and an inward background sodium current of 0.75 +/- 0.26 pA/pF. The average capacitance of a cell is 189 +/- 61 pF. Our main conclusion is the total Na/K pump current comprises currents from two di...

  1. Minimizing unbalance response of the CRBRP sodium pumps

    International Nuclear Information System (INIS)

    The unbalance response characteristics of the vertical pumps for the Clinch River Breeder Reactor Plant are investigated. Finite-element shell and beam models representative of the pump-motor structure including the rotating assembly are developed to assess structural stiffnesses of dominant joints as well as the foundation support stiffness so as to exclude the danger of resonant excitation during normal operation. Less than four mils peak-to-peak vibration amplitude at the pump tank discharge nozzle results from just 10% frequency separation between the first rocking mode and the maximum operating speed of 1116 RPM, based on 0.5% modal damping ratio and balance quality grade of ISO/ANSI G2.5 for the rotating components: motor rotor, pump shaft, Bendix diaphragm-type flexible coupling, and centrifugal double-suction impeller. Several design options are explored for raising shaft critical speed beyond 125% of maximum operating speed. NASTRAN complex eigenvalue solution is performed to take credit for damping in bearings to help meet this requirement. The mitigating effect of increasing shaft critical speed on both unbalance response and seismic response is evaluated. The influence of horizontal foundation stiffness on shaft whip is demonstrated, apart from staggering lateral modes in an effort to minimize dynamic coupling between them; higher the stiffness, less the shaft whip expressed as the peak lateral response along the vertical shaft. Parametric curves are presented illustrating the extent to which the fundamental rocking mode frequency is influenced by the combined rotational stiffness of the pump foundation and closure flange assembly. The fundamental rocking mode is raised high enough to become less sensitive to the foundation stiffness. (orig.)

  2. Sodium pump molecular activity and membrane lipid composition in two disparate ectotherms, and comparison with endotherms.

    Science.gov (United States)

    Turner, Nigel; Hulbert, A J; Else, Paul L

    2005-02-01

    Previous research has shown that the lower sodium pump molecular activity observed in tissues of ectotherms compared to endotherms, is largely related to the lower levels of polyunsaturates and higher levels of monounsaturates found in the cell membranes of ectotherms. Marine-based ectotherms, however, have very polyunsaturated membranes, and in the current study, we measured molecular activity and membrane lipid composition in tissues of two disparate ectothermic species, the octopus (Octopus vulgaris) and the bearded dragon lizard (Pogona vitticeps), to determine whether the high level of membrane polyunsaturation generally observed in marine-based ectotherms is associated with an increased sodium pump molecular activity relative to other ectotherms. Phospholipids from all tissues of the octopus were highly polyunsaturated and contained high concentrations of the omega-3 polyunsaturate, docosahexaenoic acid (22:6 (n-3)). In contrast, phospholipids from bearded dragon tissues contained higher proportions of monounsaturates and lower proportions of polyunsaturates. Sodium pump molecular activity was only moderately elevated in tissues of the octopus compared to the bearded dragon, despite the much greater level of polyunsaturation in octopus membranes. When the current data were combined with data for the ectothermic cane toad, a significant (P = 0.003) correlation was observed between sodium pump molecular activity and the content of 22:6 (n-3) in the surrounding membrane. These results are discussed in relation to recent work which shows a similar relationship in endotherms. PMID:15726386

  3. Cavitation erosion scaling: tests on a pump impeller in water and in sodium

    International Nuclear Information System (INIS)

    Tests to quantify cavitation agressivity carried out in water and in sodium (400 deg) on a model pump impeller are presented. The polished samples method has been used. It can be now applied to curved surfaces such as impeller blades with the help of new measurement devices. Results are discussed regarding scaling laws for fluid-to-fluid transposition

  4. Use of Sodium Bicarbonate in Cardiac Arrest: Current Guidelines and Literature Review.

    Science.gov (United States)

    Velissaris, Dimitrios; Karamouzos, Vassilios; Pierrakos, Charalampos; Koniari, Ioanna; Apostolopoulou, Christina; Karanikolas, Menelaos

    2016-04-01

    The aim of the review was to summarize the literature over the last 25 years regarding bicarbonate administration in out-of-hospital cardiac arrest. A PubMed search was conducted using the terms "bicarbonates" and "cardiac arrest", limited to human studies and reviews published in English (or at least with a meaningful abstract in English) in the last 25 years. Clinical and experimental data raised questions regarding the safety and effectiveness of sodium bicarbonate (SB) administration during cardiac arrest. Earlier advanced cardiac life support (ACLS) guidelines recommended routine bicarbonate administration as part of the ACLS algorithm, but recent guidelines no longer recommend its use. The debate in the literature is ongoing, but at the present time, SB administration is only recommended for cardiac arrest related to hypokalemia or overdose of tricyclic antidepressants. Several studies challenge the assumption that bicarbonate administration is beneficial for treatment of acidosis in cardiac arrest. At the present time, there is a trend against using bicarbonates in cardiac arrest, and this trend is supported by guidelines published by professional societies and organizations. PMID:26985247

  5. Cardiac Repolarization Abnormalities and Potential Evidence for Loss of Cardiac Sodium Currents on ECGs of Patients with Chagas' Heart Disease

    Science.gov (United States)

    Schlegel, T. T.; Medina, R.; Jugo, D.; Nunez, T. J.; Borrego, A.; Arellano, E.; Arenare, B.; DePalma, J. L.; Greco, E. C.; Starc, V.

    2007-01-01

    Some individuals with Chagas disease develop right precordial lead ST segment elevation in response to an ajmaline challenge test, and the prevalence of right bundle branch block (RBBB) is also high in Chagas disease. Because these same electrocardiographic abnormalities occur in the Brugada syndrome, which involves genetically defective cardiac sodium channels, acquired damage to cardiac sodium channels may also occur in Chagas disease. We studied several conventional and advanced resting 12-lead/derived Frank-lead ECG parameters in 34 patients with Chagas -related heart disease (mean age 39 14 years) and in 34 age-/gender-matched healthy controls. All ECG recordings were of 5-10 min duration, obtained in the supine position using high fidelity hardware/software (CardioSoft, Houston, TX). Even after excluding those Chagas patients who had resting BBBs, tachycardia and/or pathologic arrhythmia (n=8), significant differences remained in multiple conventional and advanced ECG parameters between the Chagas and control groups (n=26/group), especially in their respective QT interval variability indices, maximal spatial QRS-T angles and low frequency HRV powers (p=0.0006, p=0.0015 and p=0.0314 respectively). In relation to the issue of potential damage to cardiac sodium channels, the Chagas patients had: 1) greater than or equal to twice the incidence of resting ST segment elevation in leads V1-V3 (n=10/26 vs. n=5/26) and of both leftward (n=5/26 versus n=0/26) and rightward (n=7/26 versus n=3/26) QRS axis deviation than controls; 2) significantly increased filtered (40-250 Hz) QRS interval durations (92.1 8.5 versus 85.3 plus or minus 9.0 ms, p=0.022) versus controls; and 3) significantly decreased QT and especially JT interval durations versus controls (QT interval: 387.5 plus or minus 26.4 versus 408.9 plus or minus 34.6 ms, p=0.013; JT interval: 290.5 plus or minus 26.3 versus 314.8 plus or minus 31.3 ms; p=0.0029). Heart rates and Bazett-corrected QTc/JTc intervals

  6. Flavonolignans as a Novel Class of Sodium Pump Inhibitors

    Directory of Open Access Journals (Sweden)

    Martin eKubala

    2016-03-01

    Full Text Available We examined the inhibitory effects of three flavonolignans and their dehydro- derivatives, taxifolin and quercetin on the activity of the Na+/K+-ATPase (NKA. The flavonolignans silychristin, dehydrosilychristin and dehydrosilydianin inhibited NKA with IC50 of 110 ± 40 μM, 38 ± 8 µM and 36 ± 14 µM, respectively. Using the methods of molecular modeling, we identified several possible binding sites for these species on NKA and proposed the possible mechanisms of inhibition. The binding to the extracellular- or cytoplasmic C-terminal sites can block the transport of cations through the plasma membrane, while the binding on the interface of cytoplasmic domains can inhibit the enzyme allosterically. Fluorescence spectroscopy experiments confirmed the interaction of these three species with the large cytoplasmic segment connecting transmembrane helices 4 and 5 (C45. The flavonolignans are distinct from the cardiac glycosides that are currently used in NKA treatment. Because their binding sites are different, the mechanism of inhibition is different as well as the range of active concentrations, one can expect that these new NKA inhibitors would exhibit also a different biomedical actions than cardiac glycosides.

  7. Resonant photopumping of a neon lasant plasma by a sodium pump plasma

    International Nuclear Information System (INIS)

    Resonant photopumping of heliumlike neon by helium like sodium is being investigated to extend this pumping technique to the soft x-ray region. In the Na-pump/Ne-lasant system, the 1s2-1s2p1P1 line of Na X at 11.0027 A differs by 2 parts in 104 from the 1s2-1s4p1P1 line of Ne 1X at 11.0003 A. This wavelength difference corresponds to about one Doppler width at the sodium plasma temperatures (200-500 eV) required for strong Na X pump radiation. Sodium line radiation of sufficient power irradiating a properly prepared neon plasma will cause overpopulation of the Ne 1X n = 4 singlet level leading to lasing in the 4-3, 4-2, and possibly 3-2 singlet transitions. Experimentally, the current pulse from the NRL Gamble-II generator is used to produce side-by-side z-pinch plasmas of sodium fluoride (NaF) and neon. The discharges are viewed radially with x-ray diagnostics including time-integrated pinhole cameras, time-resolved x-ray diodes, and a time-integrated curved-crystal spectrograph. Measurements of the neon plasma indicate that a discharge current of about 200 kA is required to produce a neon lasant with a dominant heliumlike ground-state population. For fluorescence experiments, appropriate neon lasant conditions (density of about 1018 cm-3 and temperature of 50-100 eV) must be produced at the time of the intense sodium pump-line radiation. Fluorescence is demonstrated by observing enhancement of the 4-1 line (He-γ) from the neon plasma relative to the 3-1 line (He-γ) when the neon is pumped by sodium. An increase in this γ-to-β ratio of 25% has been observed when the sodium pump radiation is present. The results of recent experiments are reported, and their implications for future experiments are discussed

  8. Internal fluid flow management analysis for Clinch River Breeder Reactor Plant sodium pumps

    International Nuclear Information System (INIS)

    The Clinch River Breeder Reactor Plant (CRBRP) sodium pumps are currently being designed and the prototype unit is being fabricated. In the design of these large-scale pumps for elevated temperature Liquid Metal Fast Breeder Reactor (LMFBR) service, one major design consideration is the response of the critical parts to severe thermal transients. A detailed internal fluid flow distribution analysis has been performed using a computer code HAFMAT, which solves a network of fluid flow paths. The results of the analytical approach are then compared to the test data obtained on a half-scale pump model which was tested in water. The details are presented of pump internal hydraulic analysis, and test and evaluation of the half-scale model test results

  9. The specific case: cardiac amyloidosis as differential diagnosis in case of restricted cardiac pump function

    International Nuclear Information System (INIS)

    The NMR imaging data in combination with clinical characterization and echocardiography are consistent with the diagnosis of a cardiac amyloidosis. The article describes disease pattern and diagnosis based on contrast agent accumulation and diastolic functional disturbances. CT was performed to exclude pulmonary embolism.

  10. Characterization and influence of cardiac background sodium current in the atrioventricular node

    OpenAIRE

    Cheng, Hongwei; Li, Jue; James, Andrew F.; Inada, Shin; Choisy, Stéphanie C.M.; Orchard, Clive H.; Zhang, Henggui; Boyett, Mark R.; Hancox, Jules C.

    2016-01-01

    Background inward sodium current (IB,Na) that influences cardiac pacemaking has been comparatively under-investigated. The aim of this study was to determine for the first time the properties and role of IB,Na in cells from the heart's secondary pacemaker, the atrioventricular node (AVN). Myocytes were isolated from the AVN of adult male rabbits and mice using mechanical and enzymatic dispersion. Background current was measured using whole-cell patch clamp and monovalent ion substitution with...

  11. An analysis of the energetic cost of the branchial and cardiac pumps during sustained swimming in trout

    DEFF Research Database (Denmark)

    FARRELL, AP; STEFFENSEN, JF

    1987-01-01

    Experimental data are available for the oxygen cost of the branchial and cardiac pumps in fish. These data were used to theoretically analyze the relative oxygen cost of these pumps during rest and swimming in rainbow troutSalmo gairdneri. Efficiency of the heart increases with activity and so...... the relative oxygen cost of the cardiac pumps decreased from 4.6% at rest to 1.9% at the critical swimming speed. The relative oxygen cost of the branchial pump is significant in the resting and slowly swimming fish, being 10 to 15% of total oxygen uptake. However, when swimming trout switch to a ram mode...... of ventilation, a considerable saving in oxygen cost is accrued by switching the cost of ventilation from the branchial to the tail musculature. Thus, the relative oxygen cost of the branchial and cardiac pumps actually decreases at critical swimming speed compared to rest and therefore is unlikely to be a major...

  12. Temporal Analysis of Valence & Electrostatics in Ion-Motive Sodium Pump.

    Science.gov (United States)

    Fonseca, J; Kaya, S; Guennoun, S; Rakowski, R

    2007-09-01

    The present work establishes a unique framework for the simulation study of ion-motive pumps in general and the Na(+)/K(+)-ATPase, or sodium pump, in particular. We shall discuss the implications of electrostatic analysis, valence calculations, and protein cavity data, each carried over data extracted from molecular dynamics simulations, on the structure-function relationship of Na(+)/K(+)-ATPase. These diverse set of tools will be used to investigate atomic-level characteristics that remain undetermined such as ion binding and accessibility. PMID:18769504

  13. Improved Outcome of Cardiac Extracorporeal Membrane Oxygenation in Infants and Children Using Magnetic Levitation Centrifugal Pumps.

    Science.gov (United States)

    Luciani, Giovanni Battista; Hoxha, Stiljan; Torre, Salvatore; Rungatscher, Alessio; Menon, Tiziano; Barozzi, Luca; Faggian, Giuseppe

    2016-01-01

    Extracorporeal membrane oxygenation (ECMO) has traditionally been and, for the most part, still is being performed using roller pumps. Use of first-generation centrifugal pumps has yielded controversial outcomes, perhaps due to mechanical properties of the same and the ensuing risk of hemolysis and renal morbidity. Latest-generation centrifugal pumps, using magnetic levitation (ML), exhibit mechanical properties which may have overcome limitations of first-generation devices. This retrospective study aimed to assess the safety and efficacy of veno-arterial (V-A) ECMO for cardiac indications in neonates, infants, and children, using standard (SP) and latest-generation ML centrifugal pumps. Between 2002 and 2014, 33 consecutive neonates, infants, and young children were supported using V-A ECMO for cardiac indications. There were 21 males and 12 females, with median age of 29 days (4 days-5 years) and a median body weight of 3.2 kg (1.9-18 kg). Indication for V-A ECMO were acute circulatory collapse in ICU or ward after cardiac repair in 16 (49%) patients, failure to wean after repair of complex congenital heart disease in 9 (27%), fulminant myocarditis in 4 (12%), preoperative sepsis in 2 (6%), and refractory tachy-arrhythmias in 2 (6%). Central cannulation was used in 27 (81%) patients and peripheral in 6. Seven (21%) patients were supported with SP and 26 (79%) with ML centrifugal pumps. Median duration of support was 82 h (range 24-672 h), with 26 (79%) patients weaned from support. Three patients required a second ECMO run but died on support. Seventeen (51%) patients required peritoneal dialysis for acute renal failure. Overall survival to discharge was 39% (13/33 patients). All patients with fulminant myocarditis and with refractory arrhythmias were weaned, and five (83%) survived, whereas no patient supported for sepsis survived. Risk factors for hospital mortality included lower (centrifugal pumps in infants and children yields outcomes absolutely

  14. Mass transfer of stainless steel in pumped sodium loops and its effect on microstructure

    International Nuclear Information System (INIS)

    Metallography and supporting analytical techniques have been used to study the corrosion and deposition behaviour of steel material in two pumped figure-of-eight loops operating at oxygen levels of 10 and 25 ppm. Corrosion has been identified in the high temperature parts of the system and ferrite layer formation and the undercutting of steel surfaces through the formation of sodium chromite have been established in the maximum temperature and downstream positions respectively. The damaged surface layer consists of Fe-Ni particles which after removal by the flowing sodium deposit in the low temperature part of the loop. (orig.)

  15. Sodium--NaK engineering handbook. Volume IV. Sodium pumps, valves, piping, and auxiliary equipment

    Energy Technology Data Exchange (ETDEWEB)

    Foust, O J [ed.

    1978-01-01

    The handbook is useful for designers in the Liquid Metals Fast Breeder Reactor (LMFBR) program and by the engineering and scientific community performing investigation and experimentation requiring high-temperature Na and NaK technology. Data are presented for pumps, bearings and seals, valves, vessels and piping, and auxiliary equipment including vapor traps, freeze plugs, fuel-channel flow regulators, antivortexing devices, and miscellaneous mechanical elements. Reactor materials are also discussed. (FS)

  16. Pumps modelling of a sodium fast reactor design and analysis of hydrodynamic behavior

    Directory of Open Access Journals (Sweden)

    Ordóñez Ródenas José

    2016-01-01

    Full Text Available One of the goals of Generation IV reactors is to increase safety from those of previous generations. Different research platforms have been identified the need to improve the reliability of the simulation tools to ensure the capability of the plant to accommodate the design basis transients established in preliminary safety studies. The paper describes the modelling of primary pumps in advanced sodium cooled reactors using the TRACE code. Following the implementation of the models, the results obtained in the analysis of different design basis transients are compared with the simplifying approximations used in reference models. The paper shows the process to obtain a consistent pump model of the ESFR (European Sodium Fast Reactor design and the analysis of loss of flow transients triggered by pumps coast–down analyzing the thermal hydraulic neutronic coupled system response. A sensitivity analysis of the system pressure drops effect and the other relevant parameters that influence the natural convection after the pumps coast–down is also included.

  17. Characterization and isolation of a light driven sodium pump from membranes of Halobacterium halobium. Final technical progress report

    International Nuclear Information System (INIS)

    We investigated three aspects of the light driven sodium pump (halorhodopsin, which appear to be crucial to our understanding of the mechanisms employed by Halobacterium halobium and to further investigate this unique system of energy conservation. We characterized the molecular mechanisms of transmembrane sodium transport in vesicles from H. halobium with particular reference to the mechanism of couplins of light energy to net sodium translocation. We develop procedures and techniques for extracting the components of the light driven sodium pump from membranes and incorporating them into artificial membrane systems. We examine the mechanism of conversion of bacteriorhodopsin from an active to an inactive form in membrane vesicles and to relate this alternative state of this pigment to the presence of the light driven sodium pump

  18. Improved Outcome of Cardiac Extracorporeal Membrane Oxygenation in Infants and Children Using Magnetic Levitation Centrifugal Pumps.

    Science.gov (United States)

    Luciani, Giovanni Battista; Hoxha, Stiljan; Torre, Salvatore; Rungatscher, Alessio; Menon, Tiziano; Barozzi, Luca; Faggian, Giuseppe

    2016-01-01

    Extracorporeal membrane oxygenation (ECMO) has traditionally been and, for the most part, still is being performed using roller pumps. Use of first-generation centrifugal pumps has yielded controversial outcomes, perhaps due to mechanical properties of the same and the ensuing risk of hemolysis and renal morbidity. Latest-generation centrifugal pumps, using magnetic levitation (ML), exhibit mechanical properties which may have overcome limitations of first-generation devices. This retrospective study aimed to assess the safety and efficacy of veno-arterial (V-A) ECMO for cardiac indications in neonates, infants, and children, using standard (SP) and latest-generation ML centrifugal pumps. Between 2002 and 2014, 33 consecutive neonates, infants, and young children were supported using V-A ECMO for cardiac indications. There were 21 males and 12 females, with median age of 29 days (4 days-5 years) and a median body weight of 3.2 kg (1.9-18 kg). Indication for V-A ECMO were acute circulatory collapse in ICU or ward after cardiac repair in 16 (49%) patients, failure to wean after repair of complex congenital heart disease in 9 (27%), fulminant myocarditis in 4 (12%), preoperative sepsis in 2 (6%), and refractory tachy-arrhythmias in 2 (6%). Central cannulation was used in 27 (81%) patients and peripheral in 6. Seven (21%) patients were supported with SP and 26 (79%) with ML centrifugal pumps. Median duration of support was 82 h (range 24-672 h), with 26 (79%) patients weaned from support. Three patients required a second ECMO run but died on support. Seventeen (51%) patients required peritoneal dialysis for acute renal failure. Overall survival to discharge was 39% (13/33 patients). All patients with fulminant myocarditis and with refractory arrhythmias were weaned, and five (83%) survived, whereas no patient supported for sepsis survived. Risk factors for hospital mortality included lower (<2.5 kg) body weight (P = 0.02) and rescue ECMO after cardiac

  19. A Common Polymorphism of the Human Cardiac Sodium Channel Alpha Subunit (SCN5A Gene Is Associated with Sudden Cardiac Death in Chronic Ischemic Heart Disease.

    Directory of Open Access Journals (Sweden)

    Boglárka Marcsa

    Full Text Available Cardiac death remains one of the leading causes of mortality worldwide. Recent research has shed light on pathophysiological mechanisms underlying cardiac death, and several genetic variants in novel candidate genes have been identified as risk factors. However, the vast majority of studies performed so far investigated genetic associations with specific forms of cardiac death only (sudden, arrhythmogenic, ischemic etc.. The aim of the present investigation was to find a genetic marker that can be used as a general, powerful predictor of cardiac death risk. To this end, a case-control association study was performed on a heterogeneous cohort of cardiac death victims (n=360 and age-matched controls (n=300. Five single nucleotide polymorphisms (SNPs from five candidate genes (beta2 adrenergic receptor, nitric oxide synthase 1 adaptor protein, ryanodine receptor 2, sodium channel type V alpha subunit and transforming growth factor-beta receptor 2 that had previously been shown to associate with certain forms of cardiac death were genotyped using sequence-specific real-time PCR probes. Logistic regression analysis revealed that the CC genotype of the rs11720524 polymorphism in the SCN5A gene encoding a subunit of the cardiac voltage-gated sodium channel occurred more frequently in the highly heterogeneous cardiac death cohort compared to the control population (p=0.019, odds ratio: 1.351. A detailed subgroup analysis uncovered that this effect was due to an association of this variant with cardiac death in chronic ischemic heart disease (p=0.012, odds ratio = 1.455. None of the other investigated polymorphisms showed association with cardiac death in this context. In conclusion, our results shed light on the role of this non-coding polymorphism in cardiac death in ischemic cardiomyopathy. Functional studies are needed to explore the pathophysiological background of this association.

  20. Na/K pump current in aggregates of cultured chick cardiac myocytes

    OpenAIRE

    1990-01-01

    Spontaneously beating aggregates of cultured embryonic chick cardiac myocytes, maintained at 37 degrees C, were voltage clamped using a single microelectrode switching clamp to measure the current generated by the Na/K pump (Ip). In resting, steady-state preparations an ouabain- sensitive current of 0.46 +/- 0.03 microA/cm2 (n = 22) was identified. This current was not affected by 1 mM Ba, which was used to reduce inward rectifier current (IK1) and linearize the current-voltage relationship. ...

  1. Clinical effectiveness of centrifugal pump to produce pulsatile flow during cardiopulmonary bypass in patients undergoing cardiac surgery.

    Science.gov (United States)

    Gu, Y John; van Oeveren, Willem; Mungroop, Hubert E; Epema, Anne H; den Hamer, Inez J; Keizer, Jorrit J; Leuvenink, Ron P; Mariani, Massimo A; Rakhorst, Gerhard

    2011-02-01

    Although the centrifugal pump has been widely used as a nonpulsatile pump for cardiopulmonary bypass (CPB), little is known about its performance as a pulsatile pump for CPB, especially on its efficacy in producing hemodynamic energy and its clinical effectiveness. We performed a study to evaluate whether the Rotaflow centrifugal pump produces effective pulsatile flow during CPB and whether the pulsatile flow in this setting is clinically effective in adult patients undergoing cardiac surgery. Thirty-two patients undergoing CPB for elective coronary artery bypass grafting were randomly allocated to a pulsatile perfusion group (n = 16) or a nonpulsatile perfusion group (n = 16). All patients were perfused with the Rotaflow centrifugal pump. In the pulsatile group, the centrifugal pump was adjusted to the pulsatile mode (60 cycles/min) during aortic cross-clamping, whereas in the nonpulsatile group, the pump was kept in its nonpulsatile mode during the same period of time. Compared with the nonpulsatile group, the pulsatile group had a higher pulse pressure (P centrifugal pump is associated with a small gain of EEP and SHE, which does not seem to be clinically effective in adult cardiac surgical patients.

  2. 钠冷快堆超导钠泵建模与性能研究%Modeling and Performance Research on Sodium Cooled Fast Reactor Superconductive Sodium Pump

    Institute of Scientific and Technical Information of China (English)

    杨志达; 赵佳宁; 韩伟实

    2014-01-01

    为克服钠冷快堆机械式钠泵机械磨损、噪声大、泄漏以及普通电磁泵流量小、扬程小等问题,提出了大流量鞍型磁体的电磁泵作为驱动钠循环的主泵设计方案。对其结构进行了研究并建立了相应的数学模型,利用M atlab编写程序进行了不同电流、磁感应强度和温度条件下泵的扬程、流量和效率的性能研究。结果表明,扬程随通道宽度的增加、电流的减小、磁感应强度的减小而减小,效率随电流的减小、磁感应强度的减小而减小,温度高于400℃时由于接触电阻的降低可使效率提高,鞍型超导钠泵的流量可由电流、磁感应强度控制,但较为实用的是电流控制。该研究可为具体设计提供依据。%In order to overcome the shortcoming of sodium cooled fast reactor mechanical sodium pump including mechanical wear ,large noise ,sodium leakage and the shortcom-ing of electromagnetic pump including small flow rate and small pump head ,the large flow rate sodium pump design based on saddle superconductive magnet was put forward . The structure of sodium pump was researched and the mathematic model was estab-lished .The performance including pump head ,flow rate and efficiency were researched at different currents ,magnetic flux densities and temperatures using the computer code programmed with Matlab .The result shows that the pump head will reduce with the channel width increasing ,current reducing and magnetic flux density reducing ,and the efficiency will reduce with the current reducing and magnetic flux density reducing .If the temperature overtops 400 ℃ ,the efficiency will be high because of contact resistance disappearing .T he flow rate of the saddle type superconductive sodium pump can be controlled by current and magnetic flux density ,and the current is more suitable .This research can provide foundation for concreting design .

  3. Robust remote-pumping sodium laser for advanced LIDAR and guide star applications

    Science.gov (United States)

    Ernstberger, Bernhard; Enderlein, Martin; Friedenauer, Axel; Schwerdt, Robin; Wei, Daoping; Karpov, Vladimir; Leisching, Patrick; Clements, Wallace R. L.; Kaenders, Wilhelm G.

    2015-10-01

    The performance of large ground-based optical telescopes is limited due to wavefront distortions induced by atmospheric turbulence. Adaptive optics systems using natural guide stars with sufficient brightness provide a practical way for correcting the wavefront errors by means of deformable mirrors. Unfortunately, the sky coverage of bright stars is poor and therefore the concept of laser guide stars was invented, creating an artificial star by exciting resonance fluorescence from the mesospheric sodium layer about 90 km above the earth's surface. Until now, mainly dye lasers or sumfrequency mixing of solid state lasers were used to generate laser guide stars. However, these kinds of lasers require a stationary laser clean room for operation and are extremely demanding in maintenance. Under a development contract with the European Southern Observatory (ESO) and W. M. Keck Observatory (WMKO), TOPTICA Photonics AG and its partner MPB Communications have finalized the development of a next-generation sodium guide star laser system which is available now as a commercial off-the-shelf product. The laser is based on a narrow-band diode laser, Raman fiber amplifier (RFA) technology and resonant second-harmonic generation (SHG), thus highly reliable and simple to operate and maintain. It emits > 22 W of narrow-linewidth (≈ 5 MHz) continuous-wave radiation at sodium resonance and includes a re-pumping scheme for boosting sodium return flux. Due to the SHG resonator acting as spatial mode filter and polarizer, the output is diffraction-limited with RMS wavefront error space debris tracking as well as LIDAR applications.

  4. Effect of Sodium Tanshinone Ⅱ A Sulfonate on Cardiac Myocyte Hypertrophy and Its Underlying Mechanism

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Objective:To investigate the effects of sodium tanshinone Ⅱ A sulfonate (STS) on the hypertrophy induced by angiotensin Ⅱ (Ang Ⅱ) in primary cultured neonatal rat cardiac myocytes.Methods:The effect of STS on cytotoxicity was evaluated using the 3-(4,5-dimethylthiazol-2-yl)-3,5-phenytetrazoliumromide (MTT) assay.As indexes for cardiocyte hypertrophy,cell size was determined by phase contrast microscopy and protein synthesis rate was measured by 3H-leucine incorporation.The proto-oncogene c-fos mRNA expression of cardiocytes was assessed using reverse transcription polymerase chain reaction (RT-PCR).Results:STS could inhibit cardiocyte hypertrophy,increase the protein synthesis rate and enhance proto-oncogene c-los mRNA expression in cardiocytes induced by Ang Ⅱ (P<0.01),with an effect similar to that of Valsartan,the Ang Ⅱ receptor antagonist.Conclusion:STS can prevent the hypertrophy of cardiac myocytes induced by Ang Ⅱ,which may be related to its inhibition of the expression of proto-oncogene c-fos mRNA.

  5. Protective and biogenesis effects of sodium hydrosulfide on brain mitochondria after cardiac arrest and resuscitation.

    Science.gov (United States)

    Pan, Hao; Xie, Xuemeng; Chen, Di; Zhang, Jincheng; Zhou, Yaguang; Yang, Guangtian

    2014-10-15

    Mitochondrial dysfunction plays a critical role in brain injury after cardiac arrest and cardiopulmonary resuscitation (CPR). Recent studies demonstrated that hydrogen sulfide (H2S) donor compounds preserve mitochondrial morphology and function during ischemia-reperfusion injury. In this study, we sought to explore the effects of sodium hydrosulfide (NaHS) on brain mitochondria 24h after cardiac arrest and resuscitation. Male Sprague-Dawley rats were subjected to 6min cardiac arrest and then resuscitated successfully. Rats received NaHS (0.5mg/kg) or vehicle (0.9% NaCl, 1.67ml/kg) 1min before the start of CPR intravenously, followed by a continuous infusion of NaHS (1.5mg/kg/h) or vehicle (5ml/kg/h) for 3h. Neurological deficit was evaluated 24h after resuscitation and then cortex was collected for assessments. As a result, we found that rats treated with NaHS revealed an improved neurological outcome and cortex mitochondrial morphology 24h after resuscitation. We also observed that NaHS therapy reduced intracellular reactive oxygen species generation and calcium overload, inhibited mitochondrial permeability transition pores, preserved mitochondrial membrane potential, elevated ATP level and ameliorated the cytochrome c abnormal distribution. Further studies indicated that NaHS administration increased mitochondrial biogenesis in cortex at the same time. Our findings suggested that administration of NaHS 1min prior CPR and followed by a continuous infusion ameliorated neurological dysfunction 24h after resuscitation, possibly through mitochondria preservation as well as by promoting mitochondrial biogenesis.

  6. Sodium hydrosulfide attenuates hyperhomocysteinemia rat myocardial injury through cardiac mitochondrial protection.

    Science.gov (United States)

    Wang, Yuwen; Shi, Sa; Dong, Shiyun; Wu, Jichao; Song, Mowei; Zhong, Xin; Liu, Yanhong

    2015-01-01

    Hydrogen sulfide (H2S) plays an important role during rat myocardial injury. However, little is known about the role of H2S in hyperhomocysteinemia (HHcy)-induced cardiac dysfunction as well as the underlying mechanisms. In this study, we investigated whether sodium hydrosulfide (NaHS, a H2S donor) influences methionine-induced HHcy rat myocardial injury in intact rat hearts and primary neonatal rat cardiomyocytes. HHcy rats were induced by methionine (2.0 g/kg) and the daily administration of 80 μmol/L NaHS in the HHcy + NaHS treatment group. At the end of 4, 8, and 12 weeks, the ultrastructural alterations and functions of the hearts were observed using transmission electron microscopy and echocardiography system. The percentage of apoptotic cardiomyocytes, the mitochondrial membrane potential, and the production of reactive oxygen species (ROS) were measured. The expressions of cystathionine-γ-lyase (CSE), Bax and Bcl-2, caspase-3, phospho-endothelial nitric oxide synthase and the mitochondrial NOX4 and cytochrome c were analyzed by Western blotting. The results showed the cardiac dysfunction, the ultrastructural changes, and the apoptotic rate increase in the HHcy rat hearts. In the primary neonatal rat cardiomyocytes of HHcy group, ROS production was increased markedly, whereas the expression of CSE was decreased. However, treatment with NaHS significantly improved the HHcy rat hearts function, the ultrastructural changes, and decreased the levels of ROS in the primary neonatal rat cardiomyocytes administrated with HHcy group. Furthermore, NaHS down-regulated the expression of mitochondrial NOX4 and caspase-3 and Bax and inhibited the release of cytochrome c from mitochondria. In conclusion, H2S is involved in the attenuation of HHcy myocardial injury through the protection of cardiac mitochondria.

  7. The sodium pump modulates the influence of I(Na) on [Ca2+]i transients in mouse ventricular myocytes.

    OpenAIRE

    Su, Z; Sugishita, K; Ritter, M; Li, F; Spitzer, K W; Barry, W H

    2001-01-01

    To investigate whether activity of the sarcolemmal Na pump modulates the influence of sodium current on excitation-contraction (E-C) coupling, we measured [Ca(2+)](i) transients (fluo-3) in single voltage-clamped mouse ventricular myocytes ([Na+](pip) = 15 or 0 mM) when the Na pump was activated (4.4 mM K(+)(o)) and during abrupt inhibition of the pump by exposure to 0 K with a rapid solution-switcher device. After induction of steady state [Ca2+](i) transients by conditioning voltage pulses ...

  8. Bisphenol A binds to the local anesthetic receptor site to block the human cardiac sodium channel.

    Directory of Open Access Journals (Sweden)

    Andrias O O'Reilly

    Full Text Available Bisphenol A (BPA has attracted considerable public attention as it leaches from plastic used in food containers, is detectable in human fluids and recent epidemiologic studies link BPA exposure with diseases including cardiovascular disorders. As heart-toxicity may derive from modified cardiac electrophysiology, we investigated the interaction between BPA and hNav1.5, the predominant voltage-gated sodium channel subtype expressed in the human heart. Electrophysiology studies of heterologously-expressed hNav1.5 determined that BPA blocks the channel with a K(d of 25.4±1.3 µM. By comparing the effects of BPA and the local anesthetic mexiletine on wild type hNav1.5 and the F1760A mutant, we demonstrate that both compounds share an overlapping binding site. With a key binding determinant thus identified, an homology model of hNav1.5 was generated based on the recently-reported crystal structure of the bacterial voltage-gated sodium channel NavAb. Docking predictions position both ligands in a cavity delimited by F1760 and contiguous with the DIII-IV pore fenestration. Steered molecular dynamics simulations used to assess routes of ligand ingress indicate that the DIII-IV pore fenestration is a viable access pathway. Therefore BPA block of the human heart sodium channel involves the local anesthetic receptor and both BPA and mexiletine may enter the closed-state pore via membrane-located side fenestrations.

  9. Distinct functional defect of three novel Brugada syndrome related cardiac sodium channel mutations

    Directory of Open Access Journals (Sweden)

    Juang Jyh-Ming

    2009-02-01

    Full Text Available Abstract The Brugada syndrome is characterized by ST segment elevation in the right precodial leads V1-V3 on surface ECG accompanied by episodes of ventricular fibrillation causing syncope or even sudden death. The molecular and cellular mechanisms that lead to Brugada syndrome are not yet completely understood. However, SCN5A is the most well known responsible gene that causes Brugada syndrome. Until now, more than a hundred mutations in SCN5A responsible for Brugada syndrome have been described. Functional studies of some of the mutations have been performed and show that a reduction of human cardiac sodium current accounts for the pathogenesis of Brugada syndrome. Here we reported three novel SCN5A mutations identified in patients with Brugada syndrome in Taiwan (p.I848fs, p.R965C, and p.1876insM. Their electrophysiological properties were altered by patch clamp analysis. The p.I848fs mutant generated no sodium current. The p.R965C and p.1876insM mutants produced channels with steady state inactivation shifted to a more negative potential (9.4 mV and 8.5 mV respectively, and slower recovery from inactivation. Besides, the steady state activation of p.1876insM was altered and was shifted to a more positive potential (7.69 mV. In conclusion, the SCN5A channel defect related to Brugada syndrome might be diverse but all resulted in a decrease of sodium current.

  10. Genetic Polymorphisms in Endothelin-1 as Predictors for Long-Term Survival and the Cardiac Index in Patients Undergoing On-Pump Cardiac Surgery.

    Directory of Open Access Journals (Sweden)

    Ashham Mansur

    Full Text Available Genetic variants within the endothelin-1 gene (EDN1 have been associated with several cardiovascular diseases and may act as genetic prognostic markers. Here, we explored the overall relevance of EDN1 polymorphisms for long-term survival in patients undergoing on-pump cardiac surgery. A prospectively collected cohort of 455 Caucasian patients who underwent cardiac surgery with cardiopulmonary bypass was followed up for 5 years. The obtained genotypes and inferred haplotypes were analyzed for their associations with the five-year mortality rate (primary endpoint. The EDN1 T-1370G and K198N genotype distributions did not deviate from Hardy-Weinberg equilibrium and the major allele frequencies were 83% and 77%, respectively. The cardiovascular risk factors were equally distributed in terms of the different genotypes and haplotypes associated with the two polymorphisms. The five-year mortality rate did not differ among the different EDN1 T-1370G and K198N genotypes and haplotypes. Haplotype analysis revealed that carriers of the G-T (compound EDN1 T-1370G G/K198N T haplotype had a higher cardiac index than did non-carriers (p = 0.0008; however, this difference did not reach significance after adjusting for multiple testing. The results indicate that common variations in EDN1 do not act as prognostic markers for long-term survival in patients undergoing on-pump cardiac surgery.

  11. Potassium homeostasis during exercise in domestic species: the role of the sodium-potassium pump in skeletal muscle

    NARCIS (Netherlands)

    Everts, Maria E.

    2001-01-01

    In 1997, Jens Christian Skou was awarded the Nobel prize in Chemistry for his discovery and elegant description, some 40 years earlier, of the sodium-potassium (Na+,K+) pump in crab nerve fibres [37]. It is now widely accepted that this cation transport system is essential for cell function, and tha

  12. Activation of KATP channels by Na/K pump in isolated cardiac myocytes and giant membrane patches.

    OpenAIRE

    Kabakov, A Y

    1998-01-01

    Strophanthidin inhibits KATP channels in 2,4-dinitrophenol-poisoned heart cells (). The current study shows that the Na/K pump interacts with KATP current (IK-ATP) via submembrane ATP depletion in isolated giant membrane patches and in nonpoisoned guinea pig cardiac cells in whole-cell configuration. IK-ATP was inhibited by ATP, glibenclamide, or intracellular Cs+. Na/K pump inactivation by substitution of cytoplasmic Na+ for Li+ or N-methylglucamine decreased both IK-ATP by 1/3 (1 mM ATP, ze...

  13. Endurance Exercise Training Reduces Cardiac Sodium/Calcium Exchanger Expression in Animals Susceptible to Ventricular Fibrillation

    Directory of Open Access Journals (Sweden)

    Monica eKukielka

    2011-02-01

    Full Text Available Aim: Increased sodium/calcium exchanger activity (NCX1, an important regulator of cardiomyocyte cystolic calcium may provoke arrhythmias. Exercise training can decrease NCX1 expression in animals with heart failure improving cytosolic calcium regulation, and could thereby reduce the risk for ventricular fibrillation (VF. Methods: To test this hypothesis, a 2-min coronary occlusion was made during the last min. of exercise in dogs with healed myocardial infarctions; 23 had VF (S, susceptible and 13 did not (R, resistant. The animals were randomly assigned to either 10-wk exercise training (progressively increasing treadmill running (S n = 9; R n = 8 or 10-wk sedentary (S n = 14; R n = 5 groups. At the end of the 10-wk period, the exercise + ischemia test provoked VF in sedentary but not trained susceptible dogs. On a subsequent day, cardiac tissue was harvested and NCX1 protein expression was determined by Western blot. Results: In the sedentary group, NCX1 expression was significantly (ANOVA, P<0.05 higher in susceptible compared to resistant dogs. In contrast, NCX1 levels were similar in the exercise trained resistant and susceptible animals. Conclusion: These data suggest that exercise training can restore a more normal NCX1 level in dogs susceptible to ventricular fibrillation, improving cystolic calcium regulation and could thereby reduce the risk for sudden death following myocardial infarction.

  14. Negative-dominance phenomenon with genetic variants of the cardiac sodium channel Nav1.5.

    Science.gov (United States)

    Sottas, Valentin; Abriel, Hugues

    2016-07-01

    During the past two decades, many pathological genetic variants in SCN5A, the gene encoding the pore-forming subunit of the cardiac (monomeric) sodium channel Na(v)1.5, have been described. Negative dominance is a classical genetic concept involving a "poison" mutant peptide that negatively interferes with the co-expressed wild-type protein, thus reducing its cellular function. This phenomenon has been described for genetic variants of multimeric K(+) channels, which mechanisms are well understood. Unexpectedly, several pathologic SCN5A variants that are linked to Brugada syndrome also demonstrate such a dominant-negative (DN) effect. The molecular determinants of these observations, however, are not yet elucidated. This review article summarizes recent findings that describe the mechanisms underlying the DN phenomenon of genetic variants of K(+), Ca(2+), Cl(-) and Na(+) channels, and in particular Brugada syndrome variants of Na(v)1.5. This article is part of a Special Issue entitled: Cardiomyocyte Biology: Integration of Developmental and Environmental Cues in the Heart edited by Marcus Schaub and Hughes Abriel.

  15. The mesospheric sodium layer as a remotely, optically pumped magnetometer for investigation of Birkeland currents

    Science.gov (United States)

    Johnsen, Magnar G.; Matzka, Jürgen; Hoppe, Ulf-Peter

    2016-04-01

    By means of optical pumping, it is possible to use the naturally occurring sodium layer in the mesosphere to measure Earth's scalar magnetic field at ~90 km above ground. This is an altitude not accessible by other means than rockets, which only will provide point measurements of very short time scales. We are planning to modify the sodium lidar at ALOMAR in Northern Norway to be able, for the first time, to measure and monitor the magnetic field in situ in the high latitude mesosphere over longer time scales. The planned modifications to the lidar instrument will allow alternating between the new magnetometer mode and its present mode for atmospheric temperatures and winds. The technique, which has been proposed earlier for measurements at low or mid-latitudes for studies of Earth's internal magnetic field, will in our project be applied to high latitudes in the auroral zone. This opens for a completely new domain of measurements of externally generated geomagnetic variations related to currents in the magnetosphere-ionosphere system. In particular, we aim to measure the magnetic field variations in close vicinity to Birkeland currents associated with particle precipitation events penetrating to altitudes below 90 km and small-scale, discrete auroral arcs. It is, furthermore, anticipated that it will be possible to detect horizontal current structures in the E-layer on much smaller length scales than it is presently possible from ground observations alone. During the project we plan take advantage of the rich space science infrastructure located in northern Norway, including ALOMAR, EISCAT and the Tromsø Geophysical Observatory magnetometer network. If possible, we also aim to make measurements in conjunction with overpasses of the SWARM satellites.

  16. Cardiac sodium channel Na(v)1.5 interacts with and is regulated by the protein tyrosine phosphatase PTPH1

    DEFF Research Database (Denmark)

    Jespersen, Thomas; Gavillet, Bruno; van Bemmelen, Miguel X;

    2006-01-01

    In order to identify proteins interacting with the cardiac voltage-gated sodium channel Na(v)1.5, we used the last 66 amino acids of the C-terminus of the channel as bait to screen a human cardiac cDNA library. We identified the protein tyrosine phosphatase PTPH1 as an interacting protein. Pull...

  17. Urinary sodium pump inhibitor raises cytosolic free calcium concentration in rat aorta

    Energy Technology Data Exchange (ETDEWEB)

    Goto, A.; Yamada, K.; Ishii, M.; Yoshioka, M.; Ishiguro, T.; Eguchi, C.; Sugimoto, T. (Univ. of Tokyo (Japan))

    1989-06-01

    We were able to purify two distinct sodium pump inhibitors to homogeneity from human urine based on ({sup 3}H)ouabain-displacing activity from intact human erythrocytes. The polar and less polar compounds were eluted off the C18 reverse-phase column with 18% and 31% acetonitrile, respectively. The polar compound cross-reacted very weakly with specific antidigoxin antibody and lacked a characteristic ultraviolet absorption peak between 190 and 300 nm. The less polar compound showed a prominent digoxinlike immunoreactivity and had an ultraviolet spectrum similar to that of digoxin. We examined the effects of these compounds on cytosolic free calcium concentration in cultured rat vascular smooth muscle cells (A10 cells) using the fluorescent calcium chelator fura-2. Only the polar ouabain-displacing compound caused a significant increase, from 108 +/- 7 to 162 +/- 8 nM (n = 6, p less than 0.01), in cytosolic free calcium concentration in A10 cells. The rise in cytosolic free calcium concentration induced by the polar ouabain-displacing compound tended to be slower in onset and more sustained than that induced by arginine vasopressin. In contrast, ouabain and bufalin had no appreciable effects on cytosolic free calcium concentration in A10 cells. These results suggest that the polar ouabain-displacing compound we isolated from human urine may possess a vasoactive property and may play an important role in the modulation of vascular tone.

  18. Correlation between catecholamine release and sodium pump inhibition in the perfused adrenal gland of the cat

    Science.gov (United States)

    Garcia, A.G.; Garcia-Lopez, E.; Montiel, C.; Nicolas, G.P.; Sanchez-Garcia, P.

    1981-01-01

    1 Ca2+ reintroduction to retrogradely perfused and ouabain (10-4 M)-treated cat adrenal glands caused a catecholamine secretory response which was greater the longer the time of exposure to the cardiac glycoside. Such a response was proportional to the external Na+ concentration [Na+]o. 2 A qualitatively similar, yet smaller response was observed when glands were perfused with Krebs solution lacking K+ ions; thus, K+ deprivation mimicked the secretory effects of ouabain. Catecholamine secretion evoked by Ca2+ reintroduction in K+-free solution (0-K+) was also proportional to [Na+]o and greater the longer the time of exposure of the gland to 0-K+ solution. 3 The ionophore X537A also mimicked the ouabain effects, since Ca2+ reintroduction to glands treated with this agent (25 μM) caused a sharp secretory response. When added together with X537A, ouabain (10-4 M) did not modify the response to the ionophore. 4 N-ethylmaleimide (NEM), another Na+, K+-ATPase inhibitor, did not evoke the release of catecholamines; on the contrary, NEM (10-4 M) inhibited the catecholamine secretory response to high [K+]o, acetylcholine, Ca2+ reintroduction and ouabain. 5 Ouabain (10-4 M) inhibited the uptake of 86Rb into adreno-medullary tissue by 60%. Maximal inhibition had already occurred 2 min after adding the drug, indicating a lack of temporal correlation between ATPase inhibition and the ouabain secretory response, which took longer (about 30-40 min) to reach its peak. NEM (10-4 M) blocked 86Rb uptake in a similar manner. 6 The results are further evidence in favour of the presence of a Na+-Ca2+ exchange system in the chromaffin cell membrane, probably involved in the control of [Ca2+]i and in the modulation of catecholamine secretion. This system is activated by increasing [Na+]i, either directly (ionophore X537A, increased [Na+]o) or indirectly (Na+ pump inhibition). However, the simple inhibition of Na+ pumping does not always lead to a catecholamine secretory response; such is

  19. Pump, sodium, inducer, intermediate size (ISIP) (impeller/inducer/diffuser retrofit)

    International Nuclear Information System (INIS)

    This specification defines the requirements for the Intermediate-Size Inducer Pump (ISIP), which is to be made by replacing the impeller of the FFTF Prototype Pump with a new inducer, impeller, diffuser, seal, and necessary adapter hardware. Subsequent testing requirements of the complete pump assembly are included

  20. Study of an electromagnetic pump applied to a primary main pump of a large scale sodium cooled reactor

    International Nuclear Information System (INIS)

    This paper describes a future innovative design options with a parallel electromagnetic pump (EMP) system as the main circulating pump of the JSFR design. A conceptual design of EMPs integrated with an intermediate heat exchanger (IHX) is carried out. The major design parameters are consistent with the current JSFR design, where the main flow rate is 630 m3/min and the flow halving time is the same of the mechanical pump with the similar reliability. As a result of several design studies, a five parallel EMPs with IHX system has been selected from the geometry suitability for JSFR design. The EMP advantages comparing with mechanical pumps are investigated from the views of in-service inspection, maintenance and reliability. Numerical analysis with two dimensional MHD codes is conducted on a former experiment of a 160 m3/min flow rate EMP. The overall trend of the experimental data and the numerical results agrees with that in small-scale EMPs. However, the difference between the experimental data and the numerical results seems larger compared with the small-scale EMPs, which comes from large magnetic Reynolds number and interaction parameter of 160 m3/min EMP. (author)

  1. Sequential saphenous vein grafting combined with selective arterialization of middle cardiac vein during off-pump coronary artery bypass surgery

    Institute of Scientific and Technical Information of China (English)

    YU Yang; QI Dan-ni; GU Cheng-xiong

    2010-01-01

    @@ Currently coronary artery bypass grafting (CABG) is the most commonly used procedure for revascularization of coronary heart disease. However it may not be suitable for the patients with diffuse coronary artery diseases. Under this circumstance, retrograde perfusion via cardiac venous system, namely retrograde coronary venous bypass graft (CVBG), may be the proper therapeutic selection.1 The idea of myocardial revascularization by means of grafting the coronary venous system is more than a century old. However, few clinical trials and long-term outcome data have been presented. The use of venous arterialization has not been widely used. We report the use of a sequential saphenous vein graft from the aorta to middle cardiac vein in a patient with diffuse lesions in right coronary artery during off-pump coronary artery bypass surgery (OPCAB).

  2. Natriuretic peptides stimulate the cardiac sodium pump via NPR-C-coupled NOS activation

    DEFF Research Database (Denmark)

    William, M.; Hamilton, E.J.; Garcia, A.;

    2008-01-01

    with KT-5823, nitric oxide (NO)-activated guanylyl cyclase with 1H-[1,2,4]oxadiazole[4,3-a]quinoxalin-1-one (ODQ), or NO synthase with N(G)-nitro-L-arginine methyl ester (L-NAME). Since synthesis of cGMP by NPR-A and NPR-B is not NO dependent or ODQ sensitive, we exposed myocytes to AP-811, a highly...

  3. Membrane potential hyperpolarization in Mammalian cardiac cells by synchronization modulation of Na/K pumps.

    Science.gov (United States)

    Chen, Wei; Dando, Robin

    2008-02-01

    In previously reported work, we developed a new technique, synchronization modulation, to electrically activate Na/K pump molecules. The fundamental mechanism involved in this technique is a dynamic entrainment procedure of the pump molecules, carried out in a stepwise pattern. The entrainment procedure consists of two steps: synchronization and modulation. We theoretically predicted that the pump functions can be activated exponentially as a function of the membrane potential. We have experimentally demonstrated synchronization of the Na/K pump molecules and acceleration of their pumping rates by many fold through use of voltage-clamp techniques, directly monitoring the pump currents. We further applied this technique to intact skeletal muscle fibers from amphibians and found significant effects on the membrane resting potential. Here, we extend our study to intact mammalian cardiomyocytes. We employed a noninvasive confocal microscopic fluorescent imaging technique to monitor electric field-induced changes in ionic concentration gradient and membrane resting potential. Our results further confirm that the well-designed synchronization modulation electric field can effectively accelerate the Na/K pumping rate, increasing the ionic concentration gradient across the cell membrane and hyperpolarizing the membrane resting potential.

  4. [The cardioprotective action of the anticonvulsant preparation sodium valproate in disorders of cardiac contractile function caused by acute myocardial infarct in rats].

    Science.gov (United States)

    Belkina, L M; Korchazhkina, N B; Kamskova, Iu G; Fomin, N A

    1997-01-01

    The preventive and therapeutical effects of sodium valproate (SV), 200 mg/kg, on cardiac contractile disorders (developed pressure, rate-pressure products, dp/dt) were studied in rats having 2-day myocardial infarction (MI). The postinfarction rather than preinfarction use of SV substantially restricted the depressed resting left ventricular function. Given by two regimens, SV increased cardiac resistance to the maximum isometric load induced by 60-sec ligation of the ascending aorta. The cardioprotective effect of the drug was shown due to its positive chronotropic action rather than its inotropic one. Thus, SV may be used as an effective drug for the prevention and treatment of postinfarct cardiac dysfunctions. PMID:9235532

  5. The effects of residual pump blood on patient plasma free haemoglobin levels post cardiac surgery.

    Science.gov (United States)

    H, Schotola; Aj, Wetz; Af, Popov; I, Bergmann; Bc, Danner; Fa, Schöndube; M, Bauer; A, Bräuer

    2016-09-01

    At the end of cardiopulmonary bypass, there are invariably several hundred millilitres of residual pump blood in the reservoir, which can either be re-transfused or discarded. The objective of this prospective observational study was to investigate the quality of the residual pump blood, focusing on plasma free haemoglobin (pfHb) and blood cell counts. Fifty-one consecutive patients were included in the study. Forty-nine units of residual pump blood and 58 units of transfused red blood cell (RBC) concentrates were analysed. The mean preoperative pfHb of the patients was 0.057 ± 0.062 g/l, which increased gradually to 0.55 ± 0.36 g/l on arrival in the intensive care unit postoperatively. On the first postoperative day, the mean pfHb had returned to within the normal range. Our data showed that haemoglobin, haematocrit, and erythrocyte counts of residual pump blood were approximately 40% of the values in standardised RBC concentrates. Plasma free haemoglobin was significantly higher in residual pump blood compared to RBC concentrates, and nearly twice as high as the pfHb in patient blood samples taken contemporaneously. Our findings indicate that residual pump blood pfHb levels are markedly higher compared to patients' blood and RBC concentrates, but that its administration does not significantly increase patients' pfHb levels. PMID:27608341

  6. Conditioning techniques and ischemic reperfusion injury in relation to on-pump cardiac surgery

    DEFF Research Database (Denmark)

    Holmberg, Fredrik Eric Olof; Ottas, Konstantin Alex; Andreasen, Charlotte;

    2014-01-01

    OBJECTIVES: The objective was to investigate the potential protective effects of two conditioning methods, on myocardial ischemic and reperfusion injury in relation to cardiac surgery. DESIGN: Totally 68 patients were randomly assigned to either a control group (n = 23), a remote ischemic precond......, unable to show distinct protective effects of the studied conditioning methods. However, this trial can hopefully contribute to generate a productive discussion concerning limitations and future use of cardiac conditioning as well as microdialysis technique.......OBJECTIVES: The objective was to investigate the potential protective effects of two conditioning methods, on myocardial ischemic and reperfusion injury in relation to cardiac surgery. DESIGN: Totally 68 patients were randomly assigned to either a control group (n = 23), a remote ischemic...

  7. Downstream shift in sodium pump activity along the nephron during acute hypertension

    DEFF Research Database (Denmark)

    Magyar, C E; Zhang, Y; Holstein-Rathlou, N H;

    2001-01-01

    medullary Na,K-ATPase activity from 20 +/- 3.5 to 27 +/- 6.4 micromol Pi/mg protein per h while decreasing renal cortex activity from 10.9 +/- 0.9 to 6.5 +/- 0.7. Hypertension and benzolamide also doubled medullary alkaline phosphatase activity. As chronic hypertension develops in the young spontaneously......Acute hypertension rapidly inhibits proximal tubule (PT) Na,K-ATPase activity and sodium reabsorption 30 to 40%, increasing sodium and volume delivery to the thick ascending loop of Henle (TALH) and macula densa, providing the error signal for tubuloglomerular feedback. The hypothesis was tested in...... rats that an acute increase in sodium and volume delivery to the TALH would acutely increase outer medulla Na,K-ATPase activity. Flow to the TALH was increased by either (1) elevating BP (102 to 160 mmHg) for 5 min by constricting arteries (hypertension) or (2) inhibiting PT sodium and volume...

  8. Clinical evaluation of the Spiral Pump® after improvements to the original project in patients submitted to cardiac surgeries with cardiopulmonary bypass

    OpenAIRE

    Jarbas Jakson Dinkhuysen; Aron Jose Pazin de Andrade; Juliana Leme; Cibele Silva; Claudia Sanches Medina; Cristiane Célia Pereira; José Francisco Biscegli

    2014-01-01

    Objective: The objective of this paper is to present the results from Spiral Pump clinical trial after design modifications performed at its previous project. This pump applies axial end centrifugal hydraulic effects for blood pumping during cardiopulmonary bypass for patients under cardiac surgery. Methods: This study was performed in 52 patients (51% males), between 20 to 80 (67±14.4) years old weighing 53 to 102 (71.7±12.6) kg, mostly under myocardial revascularization surgery (34.6%)...

  9. Molecular basis for class Ib anti-arrhythmic inhibition of cardiac sodium channels

    DEFF Research Database (Denmark)

    Pless, Stephan Alexander; Galpin, Jason D; Frankel, Adam;

    2011-01-01

    -Williams classification system into classes Ia-c based on their distinct effects on the electrocardiogram. How can these drugs elicit distinct effects on the cardiac action potential by binding to a common receptor? Here we use fluorinated phenylalanine derivatives to test whether the electronegative surface potential...

  10. PRINCIPLES OF DEVELOPMENT MATHEMATICAL MODEL FOR RESEARCHING OF NONPULSATILE FLOW PUMP AND CARDIAC SYSTEM

    Directory of Open Access Journals (Sweden)

    I. V. Bykov

    2013-01-01

    Full Text Available Aim. The presented research uncovers the using of mathematical modeling methods for cardio-vascular system and axial blood pump interaction analysis under heart failure with combined valve pathology. The research will pro- vide data for automated pump control algorithm synthesis. Materials and methods. Mathematical model is build up by using experiments results from mock cardio-vascular circulation loop and mathematical representation of Newtonian fluid dynamics in pulsing circulation loop. The model implemented in modeling environment Simulink (Matlab. Results. Authors implemented mathematical model which describe cardio-vascular system and left-ven- tricular assistive device interaction for intact conditions. Values of parameters for intact conditions were acquired in the experiments on animals with implanted axial pump, experiments were conducted in FRCTAO. The model was verified by comparison of instantaneous blood flowrate values in experiments and in model. Conclusion. The paper present implemented mathematical model of cardio-vascular system and axial pump interaction for intact conditions, where the pump connected between left ventricle and aorta. In the next part of research authors will use the presented model to evaluate using the biotechnical system in conditions of heart failure and valve pathology. 

  11. Risk factors for delirium after on-pump cardiac surgery : A systematic review

    NARCIS (Netherlands)

    Gosselt, Alex N C; Slooter, Arjen J C; Boere, Pascal R Q; Zaal, Irene J.

    2015-01-01

    Introduction: As evidence-based effective treatment protocols for delirium after cardiac surgery are lacking, efforts should be made to identify risk factors for preventive interventions. Moreover, knowledge of these risk factors could increase validity of etiological studies in which adjustments ne

  12. Usefulness of Danaparoid sodium in patients with Heparin-induced thrombocytopenia after cardiac surgery

    OpenAIRE

    Foroughinia, Farzaneh; Farsad, Fariborz; Gholami, Kheirollah; Ahmadi, Somayeh

    2015-01-01

    Objective: Thrombocytopenia is a common problem in cardiovascular surgery patients. However, heparin-induced thrombocytopenia (HIT) is a rare but life-threatening complication of prophylaxis or treatment with heparin. Prompt management of HIT with an alternative anticoagulant is necessary due to the extreme risk of thrombotic complications. Therefore, we evaluated the effects of danaparoid in the treatment of HIT in patients with cardiac surgery who are at moderate to high risk of HIT. Method...

  13. Ionic diffusion in voltage-clamped isolated cardiac myocytes. Implications for Na,K-pump studies.

    OpenAIRE

    Mogul, D J; Singer, D H; ten Eick, R E

    1989-01-01

    The whole-cell voltage-clamp technique employing electrolyte-filled micro-pipette suction electrodes is widely used to investigate questions requiring an electrophysiological approach. With this technique, the ionic composition of the cytosol is assumed to be strongly influenced (as result of diffusion) by the ionic composition of the solution contained in the electrode. If this assumption is valid for isolated cardiac myocytes, the technique would be particularly powerful for studying the de...

  14. Ultrafast pump-probe reflectance spectroscopy: Why sodium makes Cu(In,Ga)Se2 solar cells better

    KAUST Repository

    Eid, Jessica

    2015-04-14

    Although Cu(In,Ga)Se2 (CIGS) solar cells have the highest efficiency of any thin-film solar cell, especially when sodium is incorporated, the fundamental device properties of ultrafast carrier transport and recombination in such cells remain not fully understood. Here, we explore the dynamics of charge carriers in CIGS absorber layers with varying concentrations of Na by femtosecond (fs) broadband pump-probe reflectance spectroscopy with 120 fs time resolution. By analyzing the time-resolved transient spectra in a different time domain, we show that a small amount of Na integrated by NaF deposition on top of sputtered Cu(In,Ga) prior to selenization forms CIGS, which induces slower recombination of the excited carriers. Here, we provide direct evidence for the elongation of carrier lifetimes by incorporating Na into CIGS.

  15. Assertion based verification methodology for HDL designs of primary sodium pump speed and eddy current flow measurement systems of PFBR

    International Nuclear Information System (INIS)

    With the growing complexity and size of digital designs, functional verification has become a huge challenge. The validation and testing process accounts for a significant percentage of the overall development effort and cost for electronic systems. Many studies have shown that up to 70% of the design development time and resources are spent on functional verification. Functional errors manifest themselves very early in the design flow, and unless they are detected upfront, they can result in severe consequences - both financially and from a safety viewpoint. This paper covers the various types of verification methodologies and focuses on Assertion Based Verification Methodology for HDL designs, taking as case studies, the Primary Sodium Pump Speed and Eddy Current Flow Measurement Systems of PFBR. (author)

  16. Dependence of Na-K pump current on internal Na+ in mammalian cardiac myocytes.

    Science.gov (United States)

    Mogul, D J; Singer, D H; Ten Eick, R E

    1990-08-01

    Na-K pump current (Ipump) is a function of the intracellular Na+ concentration [( Na+]i). We examined the quantitative relationship between Ipump and [Na+]i in isolated guinea pig ventricular myocytes under steady-state conditions. [Na+]i was controlled and "clamped" at several selected concentrations using wide-tipped pipette microelectrodes, and membrane current was measured using the whole cell patch voltage-clamp technique. Ipump generated at a holding potential of -40 mV was determined by measuring the change in steady-state holding current before and during exposure to dihydroouabain (1 mM); Ipump was measured at 11 levels of [Na+]i ranging from 0 to 80 mM (n = 63) with only one measurement per cell and normalized to cell capacitance to account for differences between myocytes in sarcolemmal surface area. Ipump exhibited a nonlinear dependence on [Na+]i; a Hill analysis of the relationship yielded a half-maximal [Na+]i for pump stimulation of 43.2 mM and a Hill coefficient of 1.53. An alternative analysis of the experimental data was performed assuming that occupation of three internal binding sites by Na+ is required for enzyme turnover. Regression analysis gave the best fit when only two different binding affinities (KD) are postulated. The values are KD1 = 1 mM, KD2 = KD3 = 29 mM. From the analysis using the latter model, the level of [Na+]i at which Ipump saturated closely approximated the theoretical saturation level calculated from published estimates of pump turnover rate and density. The maximal sensitivity of the Na-K pump to changes in [Na+]i occurs when internal [Na+] is within the range for the normal resting physiological level. PMID:2167023

  17. Effects of post-resuscitation administration with sodium hydrosulfide on cardiac recovery in hypoxia-reoxygenated newborn piglets.

    Science.gov (United States)

    Cheung, Po-Yin; Miedzyblocki, Margaret; Lee, Tze-Fun; Bigam, David L

    2013-10-15

    Hydrogen sulfide may protect multiple organ systems against ischemic-reperfusion injuries. It is unknown if treatment with sodium hydrosulfide (NaHS, a hydrogen sulfide donor) will improve myocardial function and minimize oxidative stress in hypoxic-reoxygenated newborn piglets. Mixed breed piglets (1-5 day, 1.5-2.5 kg) were anesthetized and acutely instrumented for the measurement of systemic, pulmonary and regional (carotid, superior mesenteric and renal) hemodynamics and blood gas parameters. The piglets were induced with normocapnic alveolar hypoxia (10-15% oxygen, 2h) followed by reoxygenation with 100% (1h) then 21% oxygen (3h). At 10 min of reoxygenation, either NaHS (10mg/kg, 5 ml) or saline (5 ml) was administered intravenously for 30 min (5 min bolus followed by 25 min of continuous infusion) in a blinded, block-randomized fashion (n = 7/group). Plasma lactate and troponin I levels and tissue markers of myocardial oxidative stress were also determined. Two hours hypoxia caused cardiogenic shock (45 ± 3% of respective normoxic baseline), reduced regional perfusion with metabolic acidosis (pH 6.94 ± 0.02). NaHS infusion significantly improved recovery of cardiac index (84 ± 3% vs. 72 ± 5% in controls), systemic oxygen delivery (84 ± 3% vs. 72 ± 5% in controls) and systemic oxygen consumption (102 ± 5% vs. 84 ± 6% in controls) at 4h of reoxygenation. NaHS had no significant effect on systemic and pulmonary blood pressures, regional blood flows, plasma lactate and troponin I levels. The myocardial glutathionine ratio was reduced in piglets treated with NaHS (vs. controls, P<0.05). Post-resuscitation administration of NaHS improves cardiac function and systemic perfusion and attenuates myocardial oxidative stress in newborn piglets following hypoxia-reoxygenation.

  18. Nav1.5 cardiac sodium channels, regulation and clinical implications

    Directory of Open Access Journals (Sweden)

    Henry Humberto León-Ariza

    2014-10-01

    Full Text Available Voltage-gated sodium channels constitute a group of membrane proteins widely distributed thought the body. In the heart, there are at least six different isoforms, being the Nav1.5 the most abundant. The channel is composed of an α subunit that is formed by four domains of six segments each, and four much smaller β subunits that provide stability and integrate other channels into the α subunit. The function of the Nav1.5 channel is modulated by intracellular cytoskeleton proteins, extracellular proteins, calcium concentration, free radicals, and medications, among other things. The study of the channel and its alterations has grown thanks to its association with pathogenic conditions such as Long QT syndrome, Brugada syndrome, atrial fibrillation, arrhythmogenic ventricular dysplasia and complications during ischemic processes.

  19. A microcalorimetric study of the sodium-potassium-pump and thermogenesis in human skeletal muscle.

    Science.gov (United States)

    Fagher, B; Sjögren, A; Monti, M

    1987-11-01

    Thermogenesis in human skeletal muscle was monitored by measurement of heat production using perfusion microcalorimetry. Heat production significantly correlated with relative body weight. The energy expenditure of the Na-K-pump (delta P), assessed after inhibition by ouabain in Krebs-Ringer phosphate buffer containing glucose and insulin, amounted to 6% of the total heat production in vastus lateralis muscle. Muscle potassium positively correlated with delta P (r = 0.84, P less than 0.005). For rectus abdominis muscle delta P was 8-15%; 95% confidence interval for the difference was 3-5% when comparison was made with vastus lateralis. The finding of a positive relationship between delta P and muscle magnesium (r = 0.68, P less than 0.04) is possibly explained by the dependence of ATP hydrolysis on internal magnesium. Our data on resting thermogenesis in small muscle samples agree to previous estimates of O2 consumption in human skeletal muscle in vivo.

  20. The β1-subunit of Na(v1.5 cardiac sodium channel is required for a dominant negative effect through α-α interaction.

    Directory of Open Access Journals (Sweden)

    Aurélie Mercier

    Full Text Available Brugada syndrome (BrS is an inherited autosomal dominant cardiac channelopathy. Several mutations on the cardiac sodium channel Na(v1.5 which are responsible for BrS lead to misfolded proteins that do not traffic properly to the plasma membrane. In order to mimic patient heterozygosity, a trafficking defective mutant, R1432G was co-expressed with Wild Type (WT Na(v1.5 channels in HEK293T cells. This mutant significantly decreased the membrane Na current density when it was co-transfected with the WT channel. This dominant negative effect did not result in altered biophysical properties of Na(v1.5 channels. Luminometric experiments revealed that the expression of mutant proteins induced a significant reduction in membrane expression of WT channels. Interestingly, we have found that the auxiliary Na channel β(1-subunit was essential for this dominant negative effect. Indeed, the absence of the β(1-subunit prevented the decrease in WT sodium current density and surface proteins associated with the dominant negative effect. Co-immunoprecipitation experiments demonstrated a physical interaction between Na channel α-subunits. This interaction occurred only when the β(1-subunit was present. Our findings reveal a new role for β(1-subunits in cardiac voltage-gated sodium channels by promoting α-α subunit interaction which can lead to a dominant negative effect when one of the α-subunits shows a trafficking defective mutation.

  1. Effect of recombinant human brain natriuretic peptide combined with sodium nitroprusside therapy on hemodynamics and cardiac in patients with acute decompensated heart failure

    Institute of Scientific and Technical Information of China (English)

    Qiao-Li Xing; Xian-Hong Ma; Lu Wang

    2016-01-01

    Objective:To evaluate the effect of recombinant human brain natriuretic peptide combined with sodium nitroprusside therapy on hemodynamics and cardiac function levels in patients with acute decompensated heart failure.Methods:A total of 118 patients with acute decompensated heart failure were randomly divided into observation group and the control group (n=59). Control group received clinical conventional therapy for heart failure, observation group received recombinant human brain natriuretic peptide combined with sodium nitroprusside therapy, and the differences in hemodynamics, cardiac function and circulation factor levels were compared between two groups after 12 hours of treatment. Results: After 12 hours of treatment, central venous pressure, right atrial pressure and pulmonary capillary wedge pressure values as well as circulating blood IL-6, hsCRP, ST2, NT-proBNP and cTnⅠlevels of observation group were lower than those of control group, and left heart GLS, GCS, GSRs, GSRe, GSRa, ROT and ROTR levels were higher than those of control group (P<0.05).Conclusions:Recombinant human brain natriuretic peptide combined with sodium nitroprusside therapy for patients with acute decompensated heart failure has significant advantages in optimizing hemodynamics, cardiac function and other aspects.

  2. Changes in cardiac glycoside receptor sites 86 rubidium uptake and intracellular sodium concentrations in the erythrocytes of patients receiving digoxin during the early phases of treatment of cardiac failure in regular rhythm and of atrial fibrillation

    International Nuclear Information System (INIS)

    Measurements of the binding of 12-α-[3H]-digoxin to the membranes of intact erythrocytes, erythrocytic 86Rb uptake and intraerythrocytic sodium concentrations have been made in the red cells of patients receiving digoxin in the short-term for atrial fibrillation or cardiac failure in regular rhythm. During the first few days of treatment [3H]-digoxin binding and 86Rb uptake fall and intraerythrocytic sodium concentrations rise. Subsequently parallel fluctuations occur in [3H]-digoxin binding and 86Rb uptake but not in intraerythrocytic sodium concentrations and the significance of the fluctuations is discussed. The values of all three measurements correlate significantly with the response of the heart in sinus rhythm as measured by QS2I. Plasma digoxin concentrations do not correlate with QS2I. (author)

  3. Sodium-potassium pump activity in white blood cells from children with an increased risk of developing hypertension--The Odense Schoolchild Study

    DEFF Research Database (Denmark)

    Hansen, H S; Nielsen, J R; Pedersen, K E;

    1993-01-01

    . A significant increase in 86rubidium uptake was present in boys as compared to girls. After adjustment for differences in sexual maturation the observed significant difference disappeared. Important correlates of pump activity were height, plasma glucose, and physical fitness. In the training study 10 boys from...... the hypertensive subgroup and 10 boys from the normotensive subgroup were also evaluated after eight months of physical training. A significant fall in 86rubidium uptake was observed. No control group was examined and probably the changes reflect some effects of sexual maturation on cation handling of cells....... These results indicate a significant effect of sexual maturation in capacity of sodium-potassium pump in children....

  4. Effects of Amiodarone and N-Desethylamiodarone on Cardiac Voltage-gated Sodium Channels

    Directory of Open Access Journals (Sweden)

    Mohammad-Reza eGhovanloo

    2016-03-01

    Full Text Available Amiodarone (AMD is a potent antiarrhythmic drug with high efficacy for treating atrial fibrillation and tachycardia. The pharmacologic profile of AMD is complex. AMD possesses biophysical characteristics of all of class I, II, III, and IV agents. Despite its adverse side effects, AMD remains the most commonly prescribed antiarrhythmic drug. AMD was described to prolong the QT interval and can lead to torsades de pointes. Our goal was to study the effects of AMD on peak and late sodium currents (INa,P and INa,L and determine whether these effects change as AMD is metabolized into N-Desethylamiodarone (DES. We hypothesized that AMD and DES block both INa,P and INa,L with similar profiles due to structural similarities. Given the inherent small amounts of INa,L in NaV1.5, we screened AMD and DES against the Long QT-3-causing mutation, ∆KPQ, to better detect any drug-mediated effect on INa,L. Our results show that AMD and DES do not affect WT or ∆KPQ activation; however, both drugs altered the apparent valence of steady-state fast-inactivation. In addition, AMD and DES preferentially block ∆KPQ peak conductance compared to WT. Both compounds significantly increase INa,L and window currents. We conclude that both compounds have pro-arrhythmic effects on NaV1.5, especially ∆KPQ; however, DES seems to have a greater pro-arrhythmic effect than AMD.

  5. Possible involvement of membrane lipids peroxidation and oxidation of catalytically essential thiols of the cerebral transmembrane sodium pump as component mechanisms of iron-mediated oxidative stress-linked dysfunction of the pump's activity

    Directory of Open Access Journals (Sweden)

    T.I. Omotayo

    2015-04-01

    Full Text Available The precise molecular events defining the complex role of oxidative stress in the inactivation of the cerebral sodium pump in radical-induced neurodegenerative diseases is yet to be fully clarified and thus still open. Herein we investigated the modulation of the activity of the cerebral transmembrane electrogenic enzyme in Fe2+-mediated in vitro oxidative stress model. The results show that Fe2+ inhibited the transmembrane enzyme in a concentration dependent manner and this effect was accompanied by a biphasic generation of aldehydic product of lipid peroxidation. While dithiothreitol prevented both Fe2+ inhibitory effect on the pump and lipid peroxidation, vitamin E prevented only lipid peroxidation but not inhibition of the pump. Besides, malondialdehyde (MDA inhibited the pump by a mechanism not related to oxidation of its critical thiols. Apparently, the low activity of the pump in degenerative diseases mediated by Fe2+ may involve complex multi-component mechanisms which may partly involve an initial oxidation of the critical thiols of the enzyme directly mediated by Fe2+ and during severe progression of such diseases; aldehydic products of lipid peroxidation such as MDA may further exacerbate this inhibitory effect by a mechanism that is likely not related to the oxidation of the catalytically essential thiols of the ouabain-sensitive cerebral electrogenic pump.

  6. Stimulation of sodium pump by vasoactive intestinal peptide in guinea-pig isolated trachea: potential contribution to mechanisms underlying relaxation of smooth muscle.

    OpenAIRE

    Morrison, K. J.; Vanhoutte, P. M.

    1996-01-01

    1. Relaxation of airway smooth muscle induced by vasoactive intestinal peptide (VIP) is mediated by adenosine 3':5' cyclic monophosphate (cyclic AMP). An interaction between the synthesis of cyclic AMP and enzymic activity of the plasmalemmal sodium pump (Na(+)-K(+)-ATPase) exists in certain isolated cell systems. This study sought to determine the contribution of Na(+)-K(+)-ATPase activity to relaxation of airway smooth muscle evoked by VIP. 2. All experiments were performed on isolated stri...

  7. EFFECTS OF OUABAIN AND DIGOXIN ON THE GENE EXPRESSION OF SODIUM PUMP α-SUBUNIT ISOFORM IN AORTIC SMOOTH MUSCLE OF RATS

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Objective To compare the effects of ouabain and digoxin on both the systolic blood pressure and sodium pump α-subunit isoforms gene expression in the aortic smooth muscle of rats. Methods Normal SpragueDawley rats were injected with ouabain (20μg·kg-1 ·d-1 ,i. p),digoxin (32 μg·kg-1 ·d-1,i. p)and normal saline once a day, respectively, and indirect systolic blood pressure was recorded once a week. Six weeks later,all the rats were killed and sodium pump α1-,α2-,and α3-subunit mRNA levels were detected in the aortic smooth muscle with reverse transcription polymerase chain reaction(RT-PCR) method. Results The systolic blood pressure of rats infused with ouabain increased significantly at the end of week 6 [132. 6± 9. 0 mmHg (1 mmHg = 0. 133 kPa)vs 115. 7±8.2mmHg, P <0. 01] ,while no difference of blood pressure was found between digoxin group and NS group (P>0.05).The expression of sodium pump α-subunit isoforms in aortic smooth muscle was regulated by either ouabain or digoxin:both ouabain and digoxin increased α1- and α3-subunit expression, α2-subunit decreased in digoxin group but unchanged in ouabain group. Conclusion These results suggest that both ouabain and digoxin could regulate sodium pump α-subunit isoform expression, which might be related to the physiological roles of endogenous ouabain and might be responsible for the difference between the pharmacological and toxicological effects of ouabain and digoxin,including their effects on blood pressure.

  8. 快堆钠泵机械密封可靠性评价%Reliability Assessment of Sodium Pump Mechanical Seal for Fast Reactor

    Institute of Scientific and Technical Information of China (English)

    浦恩山; 谷继品; 肖丽丽

    2016-01-01

    According to the collected lifetime data ,the reliability assessment of the sodi‐um pump mechanical seals for Russian fast reactor was completed by Weibull distribu‐tion .And then the reliability information of the sodium pump mechanical seals was obtained .The reliability assessment based on the collected lifetime data of domestic mechanical seals was completed by optimal confidence limit method ,whose assessment results were compared with those of Russian sodium pump mechanical seals .The calcu‐lation results show that the reliabilities for Russian sodium pump mechanical seals and domestic mechanical seals are no less than 0.947 3 and 0.874 4 ,respectively ,with 0.8 one‐sided confidence limits of 25 000 operation hours . T he results of the reliability assessment show that the reliability of the sodium pump mechanical seals for Russian pump is better than the mechanical seals’ on domestic pump ,but the gap between the two is not significant .%基于所收集的俄罗斯钠泵机械密封的寿命数据,利用基于威布尔分布的分析方法对其进行可靠性评价,得到了其可靠性信息。对国内机械密封所收集的寿命数据,利用最优置信限法对其进行可靠性评价,并将评价结果与俄罗斯钠泵机械密封的评价结果进行了对比分析。结果显示,在置信度为0畅8,寿命为25000 h时,俄罗斯钠泵机械密封的可靠度不低于0畅9473,国内的机械密封可靠度不低于0畅8744。可靠性评价结果表明,国内机械密封的可靠性与俄罗斯钠泵机械密封的可靠性有一定的差距,但差距不是很大。

  9. High-power QCW microsecond-pulse solid-state sodium beacon laser with spiking suppression and D2b re-pumping.

    Science.gov (United States)

    Bian, Qi; Bo, Yong; Zuo, Jun-wei; Guo, Chuan; Xu, Chang; Tu, Wei; Shen, Yu; Zong, Nan; Yuan, Lei; Gao, Hong-wei; Peng, Qin-jun; Chen, Hong-bin; Feng, Lu; Jin, Kai; Wei, Kai; Cui, Da-fu; Xue, Sui-jian; Zhang, Yu-dong; Xu, Zu-yan

    2016-04-15

    A 65 W quasi-continuous-wave microsecond-pulse solid-state sodium beacon laser tuned to the sodium D2a line has been developed with a linewidth of 0.3 GHz, beam quality of M2=1.38, and pulse width of 120 μs at a repetition rate of 500 Hz by sum-frequency mixing 1319 and 1064 nm diode-pumped Nd:YAG master-oscillator power-amplifier systems. The laser wavelength stability is less than ±0.15 GHz through feedback controlling. The laser spiking due to relaxation oscillations is suppressed by inserting frequency doublers in both 1319 and 1064 nm oscillators. Sodium D2b re-pumping is accomplished by tuning the frequency of the electro-optic modulator with the right D2a-D2b offset. A bright sodium laser guide star with a photon return of 1820 photons/cm2/s was achieved with the laser system when a 32 W circular polarized beam was projected to the sky during our field test at the Xinglong Observatory. PMID:27082331

  10. High-power QCW microsecond-pulse solid-state sodium beacon laser with spiking suppression and D2b re-pumping.

    Science.gov (United States)

    Bian, Qi; Bo, Yong; Zuo, Jun-wei; Guo, Chuan; Xu, Chang; Tu, Wei; Shen, Yu; Zong, Nan; Yuan, Lei; Gao, Hong-wei; Peng, Qin-jun; Chen, Hong-bin; Feng, Lu; Jin, Kai; Wei, Kai; Cui, Da-fu; Xue, Sui-jian; Zhang, Yu-dong; Xu, Zu-yan

    2016-04-15

    A 65 W quasi-continuous-wave microsecond-pulse solid-state sodium beacon laser tuned to the sodium D2a line has been developed with a linewidth of 0.3 GHz, beam quality of M2=1.38, and pulse width of 120 μs at a repetition rate of 500 Hz by sum-frequency mixing 1319 and 1064 nm diode-pumped Nd:YAG master-oscillator power-amplifier systems. The laser wavelength stability is less than ±0.15 GHz through feedback controlling. The laser spiking due to relaxation oscillations is suppressed by inserting frequency doublers in both 1319 and 1064 nm oscillators. Sodium D2b re-pumping is accomplished by tuning the frequency of the electro-optic modulator with the right D2a-D2b offset. A bright sodium laser guide star with a photon return of 1820 photons/cm2/s was achieved with the laser system when a 32 W circular polarized beam was projected to the sky during our field test at the Xinglong Observatory.

  11. Clinical Effectiveness of Centrifugal Pump to Produce Pulsatile Flow During Cardiopulmonary Bypass in Patients Undergoing Cardiac Surgery

    NARCIS (Netherlands)

    Gu, Y. John; van Oeveren, Willem; Mungroop, Hubert E.; Epema, Anne H.; den Hamer, Inez J.; Keizer, Jorrit J.; Leuvenink, Ron P.; Mariani, Massimo A.; Rakhorst, Gerhard

    2011-01-01

    Although the centrifugal pump has been widely used as a nonpulsatile pump for cardiopulmonary bypass (CPB), little is known about its performance as a pulsatile pump for CPB, especially on its efficacy in producing hemodynamic energy and its clinical effectiveness. We performed a study to evaluate w

  12. AFRL Advanced Electric Lasers Branch - Construction and Upgrade of a 50-watt Facility-Class Sodium Guidestar Pump Laser

    Science.gov (United States)

    Bronder, T.; Miller, H.; Stohs, J.; Lu, C.; Baker, J.; Lucero, A.

    The development of a reliable and effective laser source for pumping mesospheric sodium to generate an artificial guidestar has been well documented. From the early achievements with 589nm high-power dye lasers at the Keck and Lick observatories to the ground-breaking 50W CW FASOR (Frequency Addition Source of Optical Radiation) Guidestar at the Air Forces Starfire Optical Range (SOR), there has been intense interest in this technology from both the academic and military communities. Beginning in the fall of 2008, the Air Force Research Laboratorys Advanced Electric Lasers Branch began a project to build, test, verify and deliver an upgraded version of the SOR FASOR for use at the AF Maui Optical Station (AMOS) in the summer of 2010. This FASOR will be similar in design to the existing SOR device and produce 50W of diffraction limited, linearly polarized narrow linewidth 589nm light by combining the output of two injection-locked Nd:YAG ring lasers (operating at 1064nm and 1319nm) using resonant sum-frequency generation in a lithium triborate crystal (LBO). The upgraded features will include modularized sub-components, embedded control electronics, and a simplified cooling system. The first portion of this upgrade project is to reconstruct the current SOR FASOR components and include improved methods of regulating the gain modules of the two injection lasers. In parallel with this effort, the technical plans for the modularization and re-packaging of the FASOR will be finalized and coordinated with the staff at Maui. This presentation will summarize the result of these efforts to date and provide updates on the AMOS FASOR status. Additionally, plans for "next-generation" FASOR upgrades for both SOR and AMOS will also be discussed.

  13. Remote Ischemic Preconditioning for Prevention of Acute Kidney Injury in Patients Undergoing On-Pump Cardiac Surgery: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Zhang, Yabing; Zhang, Xiyang; Chi, Dongmei; Wang, Siyang; Wei, Hua; Yu, Hong; Li, Qian; Liu, Bin

    2016-09-01

    Remote ischemic preconditioning (RIPC) may attenuate acute kidney injury (AKI). However, results of studies evaluating the effect of RIPC on AKI after cardiac surgery have been controversial and contradictory.The aim of this meta-analysis is to examine the association between RIPC and AKI after on-pump cardiac surgery.The authors searched relevant studies in PubMed, EMBASE, and the Cochrane Library through December 2015.We considered for inclusion all randomized controlled trials that the role of RIPC in reducing AKI and renal replacement therapy (RRT) among patients underwent on-pump cardiac surgical procedures.We collected the data on AKI, initiation of RRT, serum creatinine (sCr) levels, and in-hospital mortality. Random- and fixed-effect models were used for pooling data.Nineteen trials including 5100 patients were included. The results of this meta-analysis showed a significant benefit of RIPC for reducing the incidence of AKI after cardiac interventions (odds ratio [OR] = 0.84; 95% confidence interval [CI], 0.73-0.98; P = 0.02). No significant difference was found in the incidence of RRT between RIPC and control (OR, 0.76, 95% CI, 0.46-1.24; P = 0.36). In addition, compared with standard medical care, RIPC showed no significant difference in postoperative sCr (IV 0.07; 95% CI, -0.03 to 0.16; P = 0.20; postoperative day 1; IV 0.00; 95% CI, -0.08 to 0.09; P = 0.92; postoperative day 2; IV 0.04; 95% CI, -0.05 to 0.12; P = 0.39; postoperative day 3), and in-hospital mortality (OR, 1.21, 95% CI, 0.64-2.30; P = 0.56).According to the results from present meta-analysis, RIPC was associated with a significant reduction AKI after on-pump cardiac surgery but incidence of RRT, postoperative sCr, and in-hospital mortality. Further high-quality randomized controlled trials and experimental researches comparing RIPC are desirable. PMID:27631199

  14. Assessment of hydraulic performance and biocompatibility of a MagLev centrifugal pump system designed for pediatric cardiac or cardiopulmonary support.

    Science.gov (United States)

    Dasse, Kurt A; Gellman, Barry; Kameneva, Marina V; Woolley, Joshua R; Johnson, Carl A; Gempp, Thomas; Marks, John D; Kent, Stella; Koert, Andrew; Richardson, J Scott; Franklin, Steve; Snyder, Trevor A; Wearden, Peter; Wagner, William R; Gilbert, Richard J; Borovetz, Harvey S

    2007-01-01

    The treatment of children with life-threatening cardiac and cardiopulmonary failure is a large and underappreciated public health concern. We have previously shown that the CentriMag is a magnetically levitated centrifugal pump system, having the utility for treating adults and large children (1,500 utilized worldwide). We present here the PediVAS, a pump system whose design was modified from the CentriMag to meet the physiological requirements of young pediatric and neonatal patients. The PediVAS is comprised of a single-use centrifugal blood pump, reusable motor, and console, and is suitable for right ventricular assist device (RVAD), left ventricular assist device (LVAD), biventricular assist device (BVAD), or extracorporeal membrane oxygenator (ECMO) applications. It is designed to operate without bearings, seals and valves, and without regions of blood stasis, friction, or wear. The PediVAS pump is compatible with the CentriMag hardware, although the priming volume was reduced from 31 to 14 ml, and the port size reduced from 3/8 to (1/4) in. For the expected range of pediatric flow (0.3-3.0 L/min), the PediVAS exhibited superior hydraulic efficiency compared with the CentriMag. The PediVAS was evaluated in 14 pediatric animals for up to 30 days, demonstrating acceptable hydraulic function and hemocompatibility. The current results substantiate the performance and biocompatibility of the PediVAS cardiac assist system and are likely to support initiation of a US clinical trial in the future. PMID:18043164

  15. Clinical evaluation of the Spiral Pump® after improvements to the original project in patients submitted to cardiac surgeries with cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Jarbas Jakson Dinkhuysen

    2014-09-01

    Full Text Available Objective: The objective of this paper is to present the results from Spiral Pump clinical trial after design modifications performed at its previous project. This pump applies axial end centrifugal hydraulic effects for blood pumping during cardiopulmonary bypass for patients under cardiac surgery. Methods: This study was performed in 52 patients (51% males, between 20 to 80 (67±14.4 years old weighing 53 to 102 (71.7±12.6 kg, mostly under myocardial revascularization surgery (34.6% and valvular surgery (32.8%. Besides the routine evaluation of the data observed in these cases, we monitored pump rotational speed, blood flow, cardiopulmonary bypass duration, urine free hemoglobin for blood cell trauma analysis (+ to 4+, lactate desidrogenase (UI/L, fibrinogen level (mg/dL and platelet count (nº/mm3. Results: Besides maintaining appropriate blood pressure and metabolic parameters it was also observed that the Free Hemoglobin levels remained normal, with a slight increase after 90 minutes of cardiopulmonary bypass. The Lactate Dehydrogenase showed an increase, with medians varying between 550-770 IU/L, whereas the decrease in Fibrinogen showed medians of 130-100 mg/dl. The number of platelets showed a slight decrease with the medians ranging from 240,000 to 200,000/mm3. No difficulty was observed during perfusion terminations, nor were there any immediate deaths, and all patients except one, were discharged in good condition. CONCLUSION: The Spiral Pump, as blood propeller during cardiopulmonary bypass, demonstrated to be reliable and safe, comprising in a good option as original and national product for this kind of application.

  16. Effect of thoracic epidural anesthesia on oxygen delivery and utilization in cardiac surgical patients scheduled to undergo off-pump coronary artery bypass surgery: A prospective study

    Directory of Open Access Journals (Sweden)

    Suryaprakash Sharadaprasad

    2011-01-01

    Full Text Available To evaluate the effect of thoracic epidural anesthesia (TEA on tissue oxygen delivery and utilization in patients undergoing cardiac surgery. This prospective observational study was conducted in a tertiary referral heart hospital. A total of 25 patients undergoing elective off-pump coronary artery bypass surgery were enrolled in this study. All patients received thoracic epidural catheter in the most prominent inter-vertebral space between C7 and T3 on the day before operation. On the day of surgery, an arterial catheter and Swan Ganz catheter (capable of measuring cardiac index was inserted. After administering full dose of local anesthetic in the epidural space, serial hemodynamic and oxygen transport parameters were measured for 30 minute prior to administration of general anesthesia, with which the study was culminated. A significant decrease in oxygen delivery index with insignificant changes in oxygen extraction and consumption indices was observed. We conclude that TEA does not affect tissue oxygenation despite a decrease in arterial pressures and cardiac output.

  17. Ouabain inhibition of the sodium-potassium pump: estimation of ED50 in different types of human leucocytes in vitro

    DEFF Research Database (Denmark)

    Møller, B; Vaag, Allan; Johansen, Torben

    1990-01-01

    uptake of K+ (86Rb+) that is sensitive to ouabain, 10(-5) mol l-1. 2. Dose-response curves for inhibition of the Na(+)-K+ pump were obtained after exposure of the cells to various concentrations of ouabain for 2.5 h when the level of pump inhibition was considered to be at steady state. 3. The ED50...... but somewhat higher when determined in an artificial medium (Ringer solution) than when determined in autologous plasma. 4. The ED50 values observed in the present study were very similar to KD values reported in the literature on ligand binding of tritiated ouabain to the same types of human leucocytes....

  18. REVIEW ARTICLE: Optical pumping-induced spatio-temporal modifications to propagation, polarization and intensity of laser beams in sodium vapour

    Science.gov (United States)

    Holzner, R.; Dangel, S.

    1998-02-01

    Circularly polarized laser beams propagating through sodium vapour and tuned to the buffer-gas-broadened atomic 1355-5111/10/1/003/img1 transition can optically pump sodium atoms into a non-absorbing ground state. This causes an intensity-dependent refractive index gradient along as well as transverse to the laser beam propagation direction, giving rise to a number of nonlinear spatio-temporal intensity and polarization pattern creating processes. In the case of a single circularly polarized laser beam we have observed self-focusing and defocusing, the transformation of the incident Gaussian beam intensity profiles into ring profiles, a large shift of about 5 GHz of the maximum of the absorption profile when suitable magnetic fields are applied and the deflection of a beam by the inhomogeneous transverse magnetic field of a current-carrying wire. When two beams of opposite circular polarization are superimposed, astonishing effects such as the mutual deflection of both beams (beam bouncing), the mutual extinction of both beams (beam switching), the separation of initially overlapping beams (beam splitting) and the mutual attraction of both beams (beam attraction) can be observed. While most of the effects can be well described for the stationary state by a 1355-5111/10/1/003/img2 to 1355-5111/10/1/003/img3 atomic transition model, the correct description of the dynamics requires the consideration of all hyperfine states.

  19. Cyclophilin B interacts with sodium-potassium ATPase and is required for pump activity in proximal tubule cells of the kidney.

    Directory of Open Access Journals (Sweden)

    Guillermo Suñé

    Full Text Available Cyclophilins (Cyps, the intracellular receptors for Cyclosporine A (CsA, are responsible for peptidyl-prolyl cis-trans isomerisation and for chaperoning several membrane proteins. Those functions are inhibited upon CsA binding. Albeit its great benefits as immunosuppressant, the use of CsA has been limited by undesirable nephrotoxic effects, including sodium retention, hypertension, hyperkalemia, interstial fibrosis and progressive renal failure in transplant recipients. In this report, we focused on the identification of novel CypB-interacting proteins to understand the role of CypB in kidney function and, in turn, to gain further insight into the molecular mechanisms of CsA-induced toxicity. By means of yeast two-hybrid screens with human kidney cDNA, we discovered a novel interaction between CypB and the membrane Na/K-ATPase β1 subunit protein (Na/K-β1 that was confirmed by pull-down, co-immunoprecipitation and confocal microscopy, in proximal tubule-derived HK-2 cells. The Na/K-ATPase pump, a key plasma membrane transporter, is responsible for maintenance of electrical Na+ and K+ gradients across the membrane. We showed that CypB silencing produced similar effects on Na/K-ATPase activity than CsA treatment in HK-2 cells. It was also observed an enrichment of both alpha and beta subunits in the ER, what suggested a possible failure on the maturation and routing of the pump from this compartment towards the plasma membrane. These data indicate that CypB through its interaction with Na/K-β1 might regulate maturation and trafficking of the pump through the secretory pathway, offering new insights into the relationship between cyclophilins and the nephrotoxic effects of CsA.

  20. BIOMATERIALS FOR ROTARY BLOOD PUMPS

    NARCIS (Netherlands)

    VANOEVEREN, W

    1995-01-01

    Rotary blood pumps are used for cardiac assist and cardiopulmonary support since mechanical blood damage is less than with conventional roller pumps. The high shear rate in the rotary pump and the reduced anticoagulation of the patient during prolonged pumping enforces high demands on the biocompati

  1. A new index of cardiac left ventricular synergic pumping efficiency to detect kinematically subtle coronary artery disease

    International Nuclear Information System (INIS)

    Detection of kinematically subtle coronary artery disease (CAD) is quite difficult when there is normal global left ventricular ejection fraction response to supine ergometric (isotonic) exercise. A new index of left ventricular synergic pumping efficiency (LV-SPE) has been defined conceptually and mathematically. Hand-grip (isometric) stress induced change of LV-SPE has been found to be a very useful parameter in detecting CAD in the presence of minimally produced wall motion abnormalities, which are liable to be otherwise scintigraphically too blurred when evaluated by isotonic exercise methods and thus evade proper analysis. (author). 21 refs., 2 figs., 1 tab

  2. A proton leak current through the cardiac sodium channel is linked to mixed arrhythmia and the dilated cardiomyopathy phenotype.

    Directory of Open Access Journals (Sweden)

    Pascal Gosselin-Badaroudine

    Full Text Available Cardiac Na(+ channels encoded by the SCN5A gene are essential for initiating heart beats and maintaining a regular heart rhythm. Mutations in these channels have recently been associated with atrial fibrillation, ventricular arrhythmias, conduction disorders, and dilated cardiomyopathy (DCM.We investigated a young male patient with a mixed phenotype composed of documented conduction disorder, atrial flutter, and ventricular tachycardia associated with DCM. Further family screening revealed DCM in the patient's mother and sister and in three of the mother's sisters. Because of the complex clinical phenotypes, we screened SCN5A and identified a novel mutation, R219H, which is located on a highly conserved region on the fourth helix of the voltage sensor domain of Na(v1.5. Three family members with DCM carried the R219H mutation.The wild-type (WT and mutant Na(+ channels were expressed in a heterologous expression system, and intracellular pH (pHi was measured using a pH-sensitive electrode. The biophysical characterization of the mutant channel revealed an unexpected selective proton leak with no effect on its biophysical properties. The H(+ leak through the mutated Na(v1.5 channel was not related to the Na(+ permeation pathway but occurred through an alternative pore, most probably a proton wire on the voltage sensor domain.We propose that acidification of cardiac myocytes and/or downstream events may cause the DCM phenotype and other electrical problems in affected family members. The identification of this clinically significant H(+ leak may lead to the development of more targeted treatments.

  3. Pump impeller

    International Nuclear Information System (INIS)

    A mixed-flow pump impeller, which may be used, for example, as a primary pump for circulating sodium as the primary coolant in a fast nuclear reactor, is described which comprises an impeller with evenly-spaced blades. Some of the blades, which are symmetrically disposed around the axis of rotation of the impeller, extend beyond the ends of the other blades towards the suction side of the pump to form an inducer. The channels defined between the extensions of the extended blades follow helical paths parallel to the axis of rotation. The leading edges of the unextended blades are interposed between the extended blades in the region of divergence of flow from the axis of rotation. The provision of the inducer reduces the risk of cavitation in the pump, which could cause rapid wear of the impeller. A shroud may be provided for the unextended blades. (author)

  4. Cardiac Expression of Skeletal Muscle Sodium Channels Increases Longitudinal Conduction Velocity in the Canine One Week Myocardial Infarction

    Science.gov (United States)

    Coronel, Ruben; Lau, David H; Sosunov, Eugene A; Janse, Michiel J; Danilo, Peter; Anyukhovsky, Evgeny P; Wilms-Schopman, Francien JG; Opthof, Tobias; Shlapakova, Iryna N; Ozgen, Nazira; Prestia, Kevin; Kryukova, Yelena; Cohen, Ira S.; Robinson, Richard B; Rosen, Michael R

    2013-01-01

    Background Skeletal muscle sodium channel (Nav1.4) expression in border zone myocardium increases action potential upstroke velocity in depolarized isolated tissue. Because resting membrane potential in the 1 week canine infarct is reduced, we hypothesized that conduction velocity (CV) is greater in Nav1.4 dogs compared to control dogs. Objective To measure CV in the infarct border zone border in dogs with and without Nav1.4 expression. Methods Adenovirus was injected in the infarct border zone in 34 dogs. The adenovirus incorporated the Nav1.4- and a green fluorescent protein (GFP) gene (Nav1.4 group, n=16) or only GFP (n=18). After 1 week, upstroke velocity and CV were measured by sequential microelectrode recordings at 4 and 7 mM [K+] in superfused epicardial slabs. High density in vivo epicardial activation mapping was performed in a subgroup (8 Nav1.4, 6 GFP) at 3–4 locations in the border zone. Microscopy and antibody staining confirmed GFP or Nav1.4 expression. Results Infarct sizes were similar between groups (30.6+/−3 % of LV mass, mean+/−SEM). Longitudinal CV was greater in Nav1.4- than in GFP- sites (58.5+/−1.8 vs 53.3+/−1.2 cm/s, 20 and 15 sites, respectively, p<0.05). Transverse CV was not different between the groups. In tissue slabs dV/dtmax was higher and CV was greater in Nav1.4 than in control at 7 mM [K+] (P<0.05). Immunohistochemical Nav1.4 staining was seen at the longitudinal ends of the myocytes. Conclusion Nav1.4 channels in myocardium surviving 1 week infarction increases longitudinal but not transverse CV, consistent with the increased dV/dtmax and with the cellular localization of Nav1.4. PMID:20385252

  5. Getting Pumped About Heart Failure

    OpenAIRE

    Mann, Douglas L.

    2014-01-01

    Heart failure is a clinical syndrome caused by dysregulated calcium handling and abnormal cardiac pumping capacity. Whalquist et al. (2014) show that upregulation of micro-RNA25 impairs calcium handling leading to pump dysfunction, and that targeting micro-RNA25 using antisense oligonucleotides reverses pump dysfunction and improves survival in mice with heart failure.

  6. Qualitative and quantitative analyses of the morphological-dynamics of early cardiac pump action using video densidometry and optical coherence tomography (OCT)

    DEFF Research Database (Denmark)

    Männer, Jörg; Thrane, Lars; Thommes, Jan;

    2010-01-01

    During the initial phase of its pump action, vertebrate embryonic hearts are seen as valveless tubular pumps. It was traditionally thought that these tubular hearts generate unidirectional blood flow via peristalsis. Recently, however, the pumping mechanism of early embryonic hearts has become a ...

  7. Beta-receptor activation increases sodium current in guinea pig heart

    Institute of Scientific and Technical Information of China (English)

    Hong-wei WANG; Zhi-fang YANG; Yin ZHANG; Jian-min YANG; Yuan-mou LIU; Ci-zhen LI

    2009-01-01

    Aim: To study the influence of β-receptor activation on sodium channel current and the physiological significance of increased sodium current with regard to the increased cardiac output caused by sympathetic excitation.Methods: Multiple experimental approaches, including ECG, action potential recording with conventional microelectrodes, whole-cell current measurements, single-channel recordings, and pumping-force measurements, were applied to guinea pig hearts and isolated ventricular myocytes.Results: Isoprenaline was found to dose-dependently shorten QRS waves, increase the amplitude and the Vmaxof action potentials, aug-ment the fast sodium current, and increase the occurrence frequencies and open time constants of the long-open and burst modes of the sodium channel. Increased levels of membrane-permeable cAMP have similar effects. In the presence of a calcium channel blocker, TTX reversed the increased pumping force produced by isoprenaline.Conclusion: Beta-adrenergic modulation increases the inward sodium current and accelerates the conduction velocity within the ventri-cles by changing the sodium channel modes, which might both be conducive to the synchronous contraction of the heart and enhance its pumping function.

  8. Transgenic Knockdown of Cardiac Sodium/Glucose Cotransporter 1 (SGLT1) Attenuates PRKAG2 Cardiomyopathy, Whereas Transgenic Overexpression of Cardiac SGLT1 Causes Pathologic Hypertrophy and Dysfunction in Mice

    OpenAIRE

    Ramratnam, Mohun; Sharma, Ravi K.; D'Auria, Stephen; Lee, So Jung; Wang, David; Huang, Xue Yin N.; Ahmad, Ferhaan

    2014-01-01

    Background The expression of a novel cardiac glucose transporter, SGLT1, is increased in glycogen storage cardiomyopathy secondary to mutations in PRKAG2. We sought to determine the role of SGLT1 in the pathogenesis of PRKAG2 cardiomyopathy and its role in cardiac structure and function. Methods and Results Transgenic mice with cardiomyocyte‐specific overexpression of human T400N mutant PRKAG2 cDNA (TGT400N) and transgenic mice with cardiomyocyte‐specific RNA interference knockdown of SGLT1 (...

  9. Sildenafil vs. Nitroprussiato de Sódio durante Teste de Reatividade Pulmonar pré-transplante cardíaco Sildenafil vs. sodium before nitroprusside for the pulmonary hypertension reversibility test before cardiac transplantation

    Directory of Open Access Journals (Sweden)

    Aguinaldo Figueiredo Freitas Jr

    2012-09-01

    Full Text Available FUNDAMENTO: A hipertensão pulmonar é associada ao pior prognóstico no pós-transplante cardíaco. O teste de reatividade pulmonar com Nitroprussiato de Sódio (NPS está associado a elevados índices de hipotensão arterial sistêmica, disfunção ventricular do enxerto transplantado e elevadas taxas de desqualificação para o transplante. OBJETIVO: Neste estudo, objetivou-se comparar os efeitos do Sildenafil (SIL e NPS sobre variáveis hemodinâmicas, neuro-hormonais e ecocardiográficas durante teste de reatividade pulmonar. MÉTODOS: Os pacientes foram submetidos, simultaneamente, ao cateterismo cardíaco direito, ao ecocardiograma e à dosagem de BNP e gasometria venosa, antes e após administração de NPS (1 - 2 µg/Kg/min ou SIL (100 mg, dose única. RESULTADOS: Ambos reduziram a hipertensão pulmonar, porém o nitrato promoveu hipotensão sistêmica significativa (Pressão Arterial Média - PAM: 85,2 vs. 69,8 mmHg, p BACKGROUND: Pulmonary hypertension is associated with a worse prognosis after cardiac transplantation. The pulmonary hypertension reversibility test with sodium nitroprusside (SNP is associated with a high rate of systemic arterial hypotension, ventricular dysfunction of the transplanted graft and high rates of disqualification from transplantation. OBJECTIVE: This study was aimed at comparing the effects of sildenafil (SIL and SNP on hemodynamic, neurohormonal and echocardiographic variables during the pulmonary reversibility test. METHODS: The patients underwent simultaneously right cardiac catheterization, echocardiography, BNP measurement, and venous blood gas analysis before and after receiving either SNP (1 - 2 µg/kg/min or SIL (100 mg, single dose. RESULTS: Both drugs reduced pulmonary hypertension, but SNP caused a significant systemic hypotension (mean blood pressure - MBP: 85.2 vs. 69.8 mm Hg; p < 0.001. Both drugs reduced cardiac dimensions and improved left cardiac function (SNP: 23.5 vs. 24.8%, p = 0

  10. Preoperative regional cerebral oxygen saturation is a predictor of postoperative delirium in on-pump cardiac surgery patients: a prospective observational trial

    OpenAIRE

    Schoen, Julika; Meyerrose, Joscha; Paarmann, Hauke; Heringlake, Matthias; Hueppe, Michael; Berger, Klaus-Ulrich

    2011-01-01

    Introduction Postoperative delirium is an important problem in patients undergoing major surgery. Cerebral oximetry is a non-invasive method to detect imbalances in the cerebral oxygen supply/demand-ratio. Low preoperative cerebral oxygen saturation (ScO2) levels have been associated with postoperative delirium in non-cardiac surgery patients. The present prospective observational study determines the relationship between pre- and intra-operative ScO2 levels and postoperative delirium in pati...

  11. Outcome of Coronary Artery Bypass Grafts: Comparison between on Pump and off Pump

    OpenAIRE

    Rasoul Ibrahim Abdulrahman; Rezayat Parvizi

    2010-01-01

    The present study was undertaken to compare the in hospital results of coronary artery bypass graft (CABG) with (on pump) or without (off pump) cardiopulmonary bypass (CPB). Data were collected on all first-time isolated CABGs with saphenous vein and/or artery grafts at Shahid Madani Hospital in Tabriz-Iran, between 2006 and 2009. Age and clinical profile were marched between on pump and off pump group patients. Patients with concomitant cardiac operations or beating pump technique were exclu...

  12. Sodium Azide

    Science.gov (United States)

    ... Matters What's New A - Z Index Facts About Sodium Azide What sodium azide is Sodium azide is a rapidly acting, ... give people sufficient warning of the danger. Where sodium azide is found and how it is used ...

  13. Pump cavitation and inducer design

    International Nuclear Information System (INIS)

    Details of past work on sodium pump development and cavitation studies executed mainly for SNR 300 were reported earlier. Among the requirements for large sodium pumps are long life (200000 hours up to 300000 hours) and small size of impeller and pump, fully meeting the process and design criteria. These criteria are the required 'Q, H, r characteristics' in combination with a low NPSH value and the avoidance of cavitation damage to the pump. The pump designer has to develop a sound hydraulic combination consisting of suction arrangement, impeller design and diffuser. On the other hand the designer is free to choose an optimal pump speed. The pump speed in its turn influences the rotor dynamic pump design and the pump drive. The introduction of the inducer as an integral part of the pump design is based on following advantages: no tip cavitation; (possible) cavitation bubbles move to the open centre due to centrifugal forces on the fluid; the head of the inducer improves the inlet conditions of the impeller. The aim of an inducer is the increase in the suction specific speed (SA value) of a pump whereby the inducer functions as a pressure source improving the impeller inlet conditions. With inducer-impeller combinations values up to SA=15000 are realistic. With the use of an inducer the overall pump sizes can be reduced with Ca. 30%. Pumps commonly available have SA values up to a maximum of ca. 10000. A development programme was executed for SNR 300 in order to reach an increase of the suction specific speed of the impeller from SA 8200 to SA 11000. Further studies to optimize pumps design for the follow up line introduced the 'inducer acting as a pre-impeller' development. This programme was executed in the period 1979-1981. At the FDO premises a scale 1 2.8 inducer impeller combination with a suction specific speed SA=15000 was developed, constructed and tested at the water test rig. This water test rig is equipped with a perspex pipe allowing also visualisation

  14. Sodium content and sodium efflux of mononuclear leucocytes from young subjects at increased risk of developing essential hypertension

    DEFF Research Database (Denmark)

    Pedersen, K E; Nielsen, J R; Klitgaard, N A;

    1990-01-01

    Mononuclear leucocytes were used as a cellular model for the in vitro measurements of volume, sodium and potassium content, sodium efflux rate constants and absolute sodium efflux in order to assess any cellular changes in young men at increased risk of developing essential hypertension, and to a...... the sodium-potassium pump seems activated....

  15. Cardiac arrest

    Science.gov (United States)

    ... Article.jsp. Accessed June 16, 2014. Myerburg RJ, Castellanos A. Approach to cardiac arrest and life-threatening ... PA: Elsevier Saunders; 2011:chap 63. Myerburg RJ, Castellanos A. Cardiac arrest and audden aardiac death. In: ...

  16. 磷酸肌酸钠复合氨甲环酸对非体外循环冠状动脉旁路移植术患者心肌和血液保护作用的研究%The myocardial and blood protectivie effects of creatine phosphate sodium combined with tranexamic acid in off-pump coronary artery bypass grafting

    Institute of Scientific and Technical Information of China (English)

    李长营; 郭爱华; 张宗旺; 张学俊; 张雷; 敖虎山

    2011-01-01

    Objective To investigate whether the supplement of creatine phosphate sodium and tranexamic acid to cardioplegic solutions can improve myocardial protection and blood conservation in off-pump coronary artery bypass graft(OPCABG).Methods 280 patients undergoing OPCABG were randomly assigned to experimental group (CP with TA group, n=70 ) , creatine phosphate sodium group (CP group, n=70), tranexamic acid group (TA group, n=70) and control group (n=70). Before BACG,creatine phosphate sodium ( 100 mg/kg) combined with tranexamic acid (30 mg/kg), creatine phosphate sodium ( 100 mg/kg),tranexamic acid (30 mg/kg), and equal volume of normal saline were given intravenously in each group respectively. Venous blood samples were taken preoperatively, and at 0, 6, 12, 24, 48, 72 h, 7 d postoperatively to analyze creatine kinase isoenzyme (CK-MB), troponin (cTnI) ; Meanwhile, the amount of cumulative chest fluid drainage and inotropic agent and blood transfused were also recorded. Results The plasma concentrations of CK-MB in experimental group at 6, 12, 24, 48, 72 h postoperatively (15±6), (14±5), (16±10), (15±6) and (13±6) U/ml and the plasma concentrations of cTnI(235±1.53), (2.72±1.46), (2.64±1.32),(1.16±0.76) and (0.48±0.24) mg/L were significantly lower than those in group CP, group TA and control group (P<0.05). The amount of postoperative cumulative chest fluid at 6, 12, 24, 48, 72 h were (246±56), (420±82), (680±114), (725±126) and (730±130) ml drainage and blood transfuison in experimental group (5/70) were also significantly lower than those in other groups (P<0.05). Conclusion For patients undergoing OPCABG, creatine phosphate sodium combined with tranexamic acid plays an important role in myocardial protection and blood conservation without increasing the surgical mortality and the incidence of postoperative complications.%目的 研究在非体外循环下行冠状动脉旁路移植术(off-pump coronary artery bypass grafting,OPCABG)中应用

  17. Centrifugal pumps

    CERN Document Server

    Anderson, HH

    1981-01-01

    Centrifugal Pumps describes the whole range of the centrifugal pump (mixed flow and axial flow pumps are dealt with more briefly), with emphasis on the development of the boiler feed pump. Organized into 46 chapters, this book discusses the general hydrodynamic principles, performance, dimensions, type number, flow, and efficiency of centrifugal pumps. This text also explains the pumps performance; entry conditions and cavitation; speed and dimensions for a given duty; and losses. Some chapters further describe centrifugal pump mechanical design, installation, monitoring, and maintenance. The

  18. Protein Phosphatase 1c Associated with the Cardiac Sodium Calcium Exchanger 1 Regulates Its Activity by Dephosphorylating Serine 68-phosphorylated Phospholemman.

    Science.gov (United States)

    Hafver, Tandekile Lubelwana; Hodne, Kjetil; Wanichawan, Pimthanya; Aronsen, Jan Magnus; Dalhus, Bjørn; Lunde, Per Kristian; Lunde, Marianne; Martinsen, Marita; Enger, Ulla Helene; Fuller, William; Sjaastad, Ivar; Louch, William Edward; Sejersted, Ole Mathias; Carlson, Cathrine Rein

    2016-02-26

    The sodium (Na(+))-calcium (Ca(2+)) exchanger 1 (NCX1) is an important regulator of intracellular Ca(2+) homeostasis. Serine 68-phosphorylated phospholemman (pSer-68-PLM) inhibits NCX1 activity. In the context of Na(+)/K(+)-ATPase (NKA) regulation, pSer-68-PLM is dephosphorylated by protein phosphatase 1 (PP1). PP1 also associates with NCX1; however, the molecular basis of this association is unknown. In this study, we aimed to analyze the mechanisms of PP1 targeting to the NCX1-pSer-68-PLM complex and hypothesized that a direct and functional NCX1-PP1 interaction is a prerequisite for pSer-68-PLM dephosphorylation. Using a variety of molecular techniques, we show that PP1 catalytic subunit (PP1c) co-localized, co-fractionated, and co-immunoprecipitated with NCX1 in rat cardiomyocytes, left ventricle lysates, and HEK293 cells. Bioinformatic analysis, immunoprecipitations, mutagenesis, pulldown experiments, and peptide arrays constrained PP1c anchoring to the K(I/V)FF motif in the first Ca(2+) binding domain (CBD) 1 in NCX1. This binding site is also partially in agreement with the extended PP1-binding motif K(V/I)FF-X5-8Φ1Φ2-X8-9-R. The cytosolic loop of NCX1, containing the K(I/V)FF motif, had no effect on PP1 activity in an in vitro assay. Dephosphorylation of pSer-68-PLM in HEK293 cells was not observed when NCX1 was absent, when the K(I/V)FF motif was mutated, or when the PLM- and PP1c-binding sites were separated (mimicking calpain cleavage of NCX1). Co-expression of PLM and NCX1 inhibited NCX1 current (both modes). Moreover, co-expression of PLM with NCX1(F407P) (mutated K(I/V)FF motif) resulted in the current being completely abolished. In conclusion, NCX1 is a substrate-specifying PP1c regulator protein, indirectly regulating NCX1 activity through pSer-68-PLM dephosphorylation.

  19. 机器人外科手术系统体外循环心脏手术的初步经验%Total endoscopic robot-assisted on-pump cardiac surgery: preliminary experience with robot-assisted surgery

    Institute of Scientific and Technical Information of China (English)

    魏来; 黄麒; 王春生; 沈金强; 夏利民; 罗红; 廖庆武; 胡克俭; 王萍; 徐竹静

    2011-01-01

    Objective To introduce our preliminary experience in total endoscopic robot-assisted onpump cardiac surgery with da Vinci system. Methods Five patients with mitral insufficiency (MI) and five patients with atrial septai defect (ASD) underwent on-pump cardiac surgical procedures using da Vinci S system from Aug. 2010 to Dec. 2010. After double-lumen endotracheal intubation and intravenous inhalation anesthesia,the peripheral extracorporeal circulation was established with femoral arterial cannula, femoral venous cannula and right internal jugular venous cannula. Through a 3 cm-length working-port and other three 0.8 cm-length mini-ports,the total endoscopic robotic-assisted operations (including mitral valve repair and ASD repair) were performed.Results All procedures were successfully performed without incision expansion or converting to sternotomy.Transesophageal echocardiography (TEE) showed no moderate or severe .m. itral valve regurgitation or atrial septal shunt. There were no in-hospital death or post-operative complications. The patients recovered quickly with less bleeding and shorter hospital stay. All patients were followed-up for 1 - 3 months and had satisfactory TEE results.Conclusion The da Vinci robotic surgery system is safe and reliable for cardiac surgery, with satisfactory outcome, mini-invasiveness, rapid recovery and bright future. (Shanghai Med J, 2011, 34: 38-42)%目的 介绍复旦大学附属中山医院应用达芬奇S机器人外科手术系统辅助开展全内镜体外循环心脏手术的初步经验.方法 2010年8-12月在达芬奇S机器人外科手术系统辅助下完成全内镜二尖瓣成形术5例,房间隔缺损修补术5例.全组患者均采用双腔气管插管、静脉吸入复合麻醉,经股动脉、股静脉及右颈内静脉插管建立外周体外循环.于右胸第4肋间隙作3 cm工作孔,右胸第3、4、6肋间隙分别作0.8 cm器械孔,由术者操控机械臂完成全内镜下心内直视手术.结果 所有

  20. Design and Commissioning Test of WKN Sodium Thermodynamic Test Loop

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    In the research of fast reactor a sodium thermodynamic test loop was designed and commissioned. Its highest operating temperature is 700℃, after the sodium is passed the cooler, the temperature of the sodium can be reduced to 300 ℃; the sodium flow is 0.2 m3/h. The loop consists of sodium electromagnetic pump, sodium flow meter, two groups of heater, two groups of cooler, surge tank, sodium vapor trap, diffusion cold trap, sodium transportation tank, electric control panel and microprocessor. It has two experimental bypass loops for research of heat transfer

  1. Cardiac Hypertrophy: A Review on Pathogenesis and Treatment

    OpenAIRE

    Ankur Rohilla; Praveen Kumar; Seema Rohilla; Ashok Kushnoor

    2012-01-01

    Cardiac hypertrophy has been considered as an important risk factor for cardiac morbidity and mortality whose prevalence has increased during the last few decades. Cardiac hypertrophy, a disease associated with the myocardium, is characterized by thickening of ventricle wall of heart and consequent reduction in the contracting ability of heart to pump the blood. Cardiac hypertrophy has been divided into two types, i.e. physiological and pathological hypertrophy. The exercise-induced increase ...

  2. Sodium Oxybate

    Science.gov (United States)

    Sodium oxybate is used to prevent attacks of cataplexy (episodes of muscle weakness that begin suddenly and ... urge to sleep during daily activities, and cataplexy). Sodium oxybate is in a class of medications called ...

  3. Sodium Test

    Science.gov (United States)

    ... be limited. Home Visit Global Sites Search Help? Sodium Share this page: Was this page helpful? Also known as: Na Formal name: Sodium Related tests: Chloride , Bicarbonate , Potassium , Electrolytes , Osmolality , Basic ...

  4. Sodium Phosphate

    Science.gov (United States)

    Sodium phosphate is used in adults 18 years of age or older to empty the colon (large intestine, bowel) ... view of the walls of the colon. Sodium phosphate is in a class of medications called saline ...

  5. Heat pumps

    CERN Document Server

    Macmichael, DBA

    1988-01-01

    A fully revised and extended account of the design, manufacture and use of heat pumps in both industrial and domestic applications. Topics covered include a detailed description of the various heat pump cycles, the components of a heat pump system - drive, compressor, heat exchangers etc., and the more practical considerations to be taken into account in their selection.

  6. Heat pumps

    CERN Document Server

    Brodowicz, Kazimierz; Wyszynski, M L; Wyszynski

    2013-01-01

    Heat pumps and related technology are in widespread use in industrial processes and installations. This book presents a unified, comprehensive and systematic treatment of the design and operation of both compression and sorption heat pumps. Heat pump thermodynamics, the choice of working fluid and the characteristics of low temperature heat sources and their application to heat pumps are covered in detail.Economic aspects are discussed and the extensive use of the exergy concept in evaluating performance of heat pumps is a unique feature of the book. The thermodynamic and chemical properties o

  7. Cardiac Malpositions

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Shi Joon; Im, Chung Gie; Yeon, Kyung Mo; Hasn, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1979-06-15

    Cardiac Malposition refers to any position of the heart other than a left-sided heart in a situs solitus individual. Associated cardiac malformations are so complex that even angiocardiographic and autopsy studies may not afford an accurate information. Although the terms and classifications used to describe the internal cardiac anatomy and their arterial connections in cardiac malpositions differ and tend to be confusing, common agreement exists on the need for a segmental approach to diagnosis. Authors present 18 cases of cardiac malpositions in which cardiac catheterization and angiocardiography were done at the Department of Radiology, Seoul National University Hospital between 1971 and 1979. Authors analyzed the clinical, radiographic, operative and autopsy findings with the emphasis on the angiocardiographic findings. The results are as follows: 1. Among 18 cases with cardiac malpositions, 6 cases had dextrocardia with situs inversus, 9 cases had dextrocardia with situs solitus and 3 cases had levocardia with situs inversus. 2. There was no genuine exception to visceroatrial concordance rule. 3. Associated cardiac malpositions were variable and complex with a tendency of high association of transposition and double outlet varieties with dextrocardia in situs solitus and levocardia in situs inversus. Only one in 6 cases of dextrocardia with situs inversus had pure transposition. 4. In two cases associated pulmonary atresia was found at surgery which was not predicted by angiocardiography. 5. Because many of the associated complex lesions can be corrected surgically provided the diagnosis is accurate, the selective biplane angiocardiography with or without cineradiography is essential.

  8. Functional studies of sodium pump isoforms

    DEFF Research Database (Denmark)

    Clausen, Michael Jakob

    unique expression profiles and specialized functional features. We use a Two Electrode Voltage Clamp setup to determine pre-steady-state and steady-state characteristics of each isoform and design chimeras to pin-point the structural elements responsible for observed differences. With this strategy we...... and glial cells express multiple isoforms of the Na+,K+-ATPase that are sorted to different specialized subcellular compartments. We are setting up a novel assay to study the details of Na+,K+-ATPase trafficking in polarized cells. With SNAP and CLIP tagged Na+,K+-ATPase isoforms we can track newly...

  9. Centrifugal pumps

    CERN Document Server

    Gülich, Johann Friedrich

    2014-01-01

    This book gives an unparalleled, up-to-date, in-depth treatment of all kinds of flow phenomena encountered in centrifugal pumps including the complex interactions of fluid flow with vibrations and wear of materials. The scope includes all aspects of hydraulic design, 3D-flow phenomena and partload operation, cavitation, numerical flow calculations, hydraulic forces, pressure pulsations, noise, pump vibrations (notably bearing housing vibration diagnostics and remedies), pipe vibrations, pump characteristics and pump operation, design of intake structures, the effects of highly viscous flows, pumping of gas-liquid mixtures, hydraulic transport of solids, fatigue damage to impellers or diffusers, material selection under the aspects of fatigue, corrosion, erosion-corrosion or hydro-abrasive wear, pump selection, and hydraulic quality criteria. As a novelty, the 3rd ed. brings a fully analytical design method for radial impellers, which eliminates the arbitrary choices inherent to former design procedures. The d...

  10. Pumping life

    DEFF Research Database (Denmark)

    Sitsel, Oleg; Dach, Ingrid; Hoffmann, Robert Daniel

    2012-01-01

    The name PUMPKIN may suggest a research centre focused on American Halloween traditions or the investigation of the growth of vegetables – however this would be misleading. Researchers at PUMPKIN, short for Centre for Membrane Pumps in Cells and Disease, are in fact interested in a large family o......’. Here we illustrate that the pumping of ions means nothing less than the pumping of life....

  11. Clinical experience with the Sarns centrifugal pump.

    Science.gov (United States)

    Curtis, J J; Walls, J T; Demmy, T L; Boley, T M; Schmaltz, R A; Goss, C F; Wagner-Mann, C C

    1993-07-01

    Since October 1986, we have had experience with 96 Sarns centrifugal pumps in 72 patients (pts). Heparinless left atrial to femoral artery or aorta bypass was used in 14 pts undergoing surgery on the thoracic aorta with 13 survivors (93%). No paraplegia or device-related complications were observed. In 57 patients, the Sarns centrifugal pump was used as a univentricular (27 pts) or biventricular (30 pts) cardiac assist device for postcardiotomy cardiogenic shock. In these patients, cardiac assist duration ranged from 2 to 434 h with a hospital survival rate of 29% in those requiring left ventricular assist and 13% in those requiring biventricular assist. Although complications were ubiquitous in this mortally ill patient population, in 5,235 pump-hours, no pump thrombosis was observed. Hospital survivors followed for 4 months to 6 years have enjoyed an improved functional class. We conclude that the Sarns centrifugal pump is an effective cardiac assist device when used to salvage patients otherwise unweanable from cardiopulmonary bypass. Partial left ventricular bypass using a centrifugal pump has become our procedure of choice for unloading the left ventricle and for maintenance of distal aortic perfusion pressure when performing surgery on the thoracic aorta. This clinical experience with the Sarns centrifugal pump appears to be similar to that reported with other centrifugal assist devices.

  12. Cardiac rehabilitation

    Science.gov (United States)

    ... attack or other heart problem. You might consider cardiac rehab if you have had: Heart attack Coronary heart disease (CHD) Heart failure Angina (chest pain) Heart or heart valve surgery Heart transplant Procedures such as angioplasty and stenting In some ...

  13. 硫氢化钠对慢性心力衰竭大鼠心功能及心脏结构的影响%Sodium hydrosulfide improves cardiac functions and structures in rats with chronic heart failure

    Institute of Scientific and Technical Information of China (English)

    李晓惠; 张超英; 张霆

    2011-01-01

    Objective To explore the effects of sodium hydrosulfide ( NaHS),a hydrogen sulphide (H2S) donor,on cardiac functions and structures in rats with chronic heart failure induced by volume overload and examine its influence on cardiac remodelling.Methods A total of 47 SD rats ( 120 - 140 g) were randomly divided into 5 groups:shunt group ( n =11 ),sham group ( n =8),shunt + NaHS group ( n =10),sham + NaHS group ( n =8) and shunt + phentolamine group (n =10).The rat model of chronic heart failure was induced by abdominal aorta-inferior vena cava puncture.At Week 8 post-operation,hemodynamic parameters,microstructures and ultrastructures of myocardial tissues were analyzed.Extracellular collagen content in myocardial tissues was analyzed after Sirius red staining.Right ventricular hydroxyproline concentration was determined and compared.Results At Week 8 post-operation,compared with the sham operation and shunt + NaHS groups,the shunt group showed significantly increased right ventricular systolic pressure (RVSP) and right ventricular end diastolic pressure (RVEDP) ( mm Hg:35.2 ±3.9 vs 21.4 ±3.7 and 28.1 ±2.7,32 ±5 vs 21 ±4 and 26 ±4,all P <0.05,1 mm Hg =0.133 kPa).The RV peak rate of contraction and relaxation markedly decreased ( RV ± dp/dt max) ( mm Hg/s:1528 ± 113 vs 2336 ± 185 and 1835 ± 132,1331 ± 107 vs 2213 ± 212 and 1768 ± 116,all P < 0.05).It was found microscopically that myocardial fibers in the shunt group were irregularly arranged,partially cytolyzed and infiltrated by inflammatory cells.Electron microscopy revealed that myocardial fibers thickened non-uniformly in the shunt group,some fiber mitochondria were highly swollen and contained vacuoles.And sarcoplasmic reticulum appeared slightly dilated.Polarized microscopy indicated that,collagen content (particularly type-Ⅰ collagen) increased in the shunt group compared with the sham operation group.Additionally,compared with the shunt group,the shunt and NaHS treatment groups showed an

  14. Liquid-metal pumps for large-scale breeder-reactor plant (prototype pump)

    Energy Technology Data Exchange (ETDEWEB)

    Lindsay, M. (comp.)

    1976-07-01

    This report presents the recommended pump design for use in Large Scale Liquid Metal Fast Breeder Reactor plants. The base design for the pump will circulate 127,000 GPM of liquid sodium at temperatures up to 850/sup 0/F and with a total discharge head at the design point of 500 feet Na with an impeller that is 40 feet below the sodium seal. The pump design is predicated on developing an impeller design which will have a suction specific speed (S/sub n/) of about 20,000 with 20 feet NPSH available, which will result in a pump speed of 530 RPM at design conditions. The design is based on the technology developed in the design and fabrication of FFTF pumps, the design efforts for the Clinch River Breeder Reactor Pump design study and other technology.

  15. Adopt Various Teaching Methods: Giving Lessons on the Basic Function of Cell Based on Teaching of Sodium Potassium Pump%采用多种教学法——以钠钾泵为主线讲好细胞基本功能的体会

    Institute of Scientific and Technical Information of China (English)

    唐云; 张燕辉

    2012-01-01

    When giving lessons on the basic function of physiology cells, the author teaches complex and abstract bioelectric phenomenon based on sodium potassium pump by using various teaching methods like using multi-media courseware.%在生理学细胞的基本功能这一章节的授课中,以钠钾泵为主线,采用演示动态多媒体课件为主的多种教学手段,将抽象、复杂的细胞生物电现象,讲得比较透彻和直观.

  16. Physiological and pathological cardiac hypertrophy.

    Science.gov (United States)

    Shimizu, Ippei; Minamino, Tohru

    2016-08-01

    The heart must continuously pump blood to supply the body with oxygen and nutrients. To maintain the high energy consumption required by this role, the heart is equipped with multiple complex biological systems that allow adaptation to changes of systemic demand. The processes of growth (hypertrophy), angiogenesis, and metabolic plasticity are critically involved in maintenance of cardiac homeostasis. Cardiac hypertrophy is classified as physiological when it is associated with normal cardiac function or as pathological when associated with cardiac dysfunction. Physiological hypertrophy of the heart occurs in response to normal growth of children or during pregnancy, as well as in athletes. In contrast, pathological hypertrophy is induced by factors such as prolonged and abnormal hemodynamic stress, due to hypertension, myocardial infarction etc. Pathological hypertrophy is associated with fibrosis, capillary rarefaction, increased production of pro-inflammatory cytokines, and cellular dysfunction (impairment of signaling, suppression of autophagy, and abnormal cardiomyocyte/non-cardiomyocyte interactions), as well as undesirable epigenetic changes, with these complex responses leading to maladaptive cardiac remodeling and heart failure. This review describes the key molecules and cellular responses involved in physiological/pathological cardiac hypertrophy. PMID:27262674

  17. Development of sodium technology

    International Nuclear Information System (INIS)

    The objective of present study is to produce the experimental data for development and verification of computer codes for development of LMR and to develop the preliminary technologies for the future large scale verification experiments. A MHD experimental test loop has been constructed for the quantitative analysis of the effect of magnetic field on the sodium flow and experiments are carried out for three EM pumps. The previous pressure drop correlations are evaluated using the experimental data obtained from the pressure drop experiment in a 19-pin fuel assembly with wire spacer. An dimensionless variable is proposed to describe the amplitude and frequency of the fluctuation of free surface using the experimental data obtained from free surface experimental apparatus and an empirical correlation is developed using this dimensionless variable. An experimental test loop is constructed to measure the flow characteristics in IHX shell side and the local pressure drop in fuel assembly, and to test the vibration behaviour of fuel pins due to flow induced vibration. The sodium two-phase flow measuring technique using the electromagnetic flowmeter is developed and the sodium differential pressure drop measuring technique using the method of direct contact of sodium and oil is established. The work on the analysis of sodium fire characteristics and produce data for vlidation of computer code is performed. Perfect reopen time of self plugged leak path was observed to be about 130 minutes after water leak initiation. Reopen shape of a specimen appeared to be double layer of circular type, and reopen size of this specimen surface was about 2mm diameter on sodium side. In small water leakage experiments, the following correlation equation about the reopen time between sodium temperature and initial leak rate was obtained, τc = δ·g-0.83·10(3570/TNa-3.34), in 400-500 deg C of liquid sodium atmosphere. The characteristics of pressure propagation and gas flow, and pressure

  18. Development of sodium technology

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Sung Tai; Nam, H. Y.; Choi, Y. D. [and others

    2000-05-01

    The objective of present study is to produce the experimental data for development and verification of computer codes for development of LMR and to develop the preliminary technologies for the future large scale verification experiments. A MHD experimental test loop has been constructed for the quantitative analysis of the effect of magnetic field on the sodium flow and experiments are carried out for three EM pumps. The previous pressure drop correlations are evaluated using the experimental data obtained from the pressure drop experiment in a 19-pin fuel assembly with wire spacer. An dimensionless variable is proposed to describe the amplitude and frequency of the fluctuation of free surface using the experimental data obtained from free surface experimental apparatus and an empirical correlation is developed using this dimensionless variable. An experimental test loop is constructed to measure the flow characteristics in IHX shell side and the local pressure drop in fuel assembly, and to test the vibration behaviour of fuel pins due to flow induced vibration. The sodium two-phase flow measuring technique using the electromagnetic flowmeter is developed and the sodium differential pressure drop measuring technique using the method of direct contact of sodium and oil is established. The work on the analysis of sodium fire characteristics and produce data for vlidation of computer code is performed. Perfect reopen time of self plugged leak path was observed to be about 130 minutes after water leak initiation. Reopen shape of a specimen appeared to be double layer of circular type, and reopen size of this specimen surface was about 2mm diameter on sodium side. In small water leakage experiments, the following correlation equation about the reopen time between sodium temperature and initial leak rate was obtained, {tau}{sub c} = {delta}{center_dot}g{sup -0.83}{center_dot}10{sup (3570/T{sub Na}-3.34)}, in 400-500 deg C of liquid sodium atmosphere. The characteristics

  19. Hidden Sodium

    Centers for Disease Control (CDC) Podcasts

    2013-03-04

    In this podcast, learn about reducing sodium intake by knowing what to eat and the main sources of sodium in the diet. It's important for a healthy lifestyle.  Created: 3/4/2013 by National Center for Chronic Disease Prevention and Health Promotion (NCCDPHP).   Date Released: 3/4/2013.

  20. Prevalence of cardiac dyssynchrony and correlation with atrio-ventricular block and QRS width in dilated cardiomyopathy

    DEFF Research Database (Denmark)

    Anzouan-Kacou, J B; Ncho-Mottoh, M P; Konin, C;

    2012-01-01

    Cardiac dyssynchrony causes disorganised cardiac contraction, delayed wall contraction and reduced pumping efficiency. We aimed to assess the prevalence of different types of dyssynchrony in patients with dilated cardiomyopathy (DCM), and to establish the correlation between atrio-ventricular blo...

  1. Dietary sodium

    DEFF Research Database (Denmark)

    Graudal, Niels

    2015-01-01

    The 2013 Institute of Medicine (IOM) report "Sodium Intake in Populations: Assessment of Evidence" did not support the current recommendations of the IOM and the American Heart Association (AHA) to reduce daily dietary sodium intake to below 2,300 mg. The report concluded that the population......-based health outcome evidence was not sufficient to define a safe upper intake level for sodium. Recent studies have extended this conclusion to show that a sodium intake below 2,300 mg/day is associated with increased mortality. In spite of this increasing body of evidence, the AHA, Centers for Disease...... Control (CDC), other public health advisory bodies, and major medical journals have continued to support the current policy of reducing dietary sodium....

  2. Technological Solutions for Cardiac Surgery in the Elderly

    OpenAIRE

    Rony-Reuven Nir; Gil Bolotin

    2013-01-01

    The current review addresses contemporary technological advances in cardiac surgery performed on octogenarian patients, namely off-pump coronary artery bypass grafting (CABG), proximal anastomosis device, routine use of intraoperative epiaortic ultrasound, proximal anastomosis without clamping, transcatheter aortic valve implantation (TAVI), and brain protection during cardiac surgery.

  3. Neuromuscular blockade in cardiac surgery: An update for clinicians

    OpenAIRE

    Hemmerling Thomas; Russo Gianluca; Bracco David

    2008-01-01

    There have been great advancements in cardiac surgery over the last two decades; the widespread use of off-pump aortocoronary bypass surgery, minimally invasive cardiac surgery, and robotic surgery have also changed the face of cardiac anaesthesia. The concept of "Fast-track anaesthesia" demands the use of nondepolarising neuromuscular blocking drugs with short duration of action, combining the ability to provide (if necessary) sufficiently profound neuromuscular blockade during surgery and i...

  4. Cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc [Charite - Universitaetsmedizin Berlin (Germany). Inst. fuer Radiologie

    2011-07-01

    Computed tomography of the heart has become a highly accurate diagnostic modality that is attracting increasing attention. This extensively illustrated book aims to assist the reader in integrating cardiac CT into daily clinical practice, while also reviewing its current technical status and applications. Clear guidance is provided on the performance and interpretation of imaging using the latest technology, which offers greater coverage, better spatial resolution, and faster imaging. The specific features of scanners from all four main vendors, including those that have only recently become available, are presented. Among the wide range of applications and issues to be discussed are coronary artery bypass grafts, stents, plaques, and anomalies, cardiac valves, congenital and acquired heart disease, and radiation exposure. Upcoming clinical uses of cardiac CT, such as plaque imaging and functional assessment, are also explored. (orig.)

  5. Cardiac echinococcosis

    Directory of Open Access Journals (Sweden)

    Ivanović-Krstić Branislava A.

    2002-01-01

    Full Text Available Cardiac hydatid disease is rare. We report on an uncommon hydatid cyst localized in the right ventricular wall, right atrial wall tricuspid valve left atrium and pericard. A 33-year-old woman was treated for cough, fever and chest pain. Cardiac echocardiograpic examination revealed a round tumor (5.8 x 4 cm in the right ventricular free wall and two smaller cysts behind that tumor. There were cysts in right atrial wall and tricuspidal valve as well. Serologic tests for hydatidosis were positive. Computed tomography finding was consistent with diagnosis of hydatid cyst in lungs and right hylar part. Surgical treatment was rejected due to great risk of cardiac perforation. Medical treatment with albendazole was unsuccessful and the patient died due to systemic hydatid involvement of the lungs, liver and central nervous system.

  6. Analysis of curative effect of low molecular heparin sodium for pulmonary heart disease cardiac failure%低分子肝素钠在肺源性心脏病心力衰竭中的治疗效果分析

    Institute of Scientific and Technical Information of China (English)

    吴文海; 黄艺芳

    2015-01-01

    ObjectiveTo investigate curative effect of low molecular heparin sodium for pulmonary heart disease cardiac failure patients.MethodsA total of 86 pulmonary heart disease cardiac failure patients were randomly divided into observation group and control group, with 43 cases in each group. Both groups received conventional treatment, and the observation group received additional low molecular heparin sodium. Their hemodynamic indexes were observed for curative effect evaluation.ResultsThe observation group had better hemodynamic indexes after treatment than the control group, and their difference had statistical significance (P<0.05). Total effective rate of the observation group was higher as 93.0% than 76.7% of the control group, and their difference had statistical significance (P<0.05).ConclusionLow molecular heparin sodium provides remarkable curative effect for pulmonary heart disease cardiac failure, and it is worthy of referring.%目的:探讨低分子肝素钠在肺源性心脏病心力衰竭患者中的治疗效果。方法86例肺源性心脏病心力衰竭患者,随机分为观察组和对照组,各43例。两组均给予常规治疗,观察组同时给予低分子肝素钠治疗。观察血液流变学指标,评定治疗效果。结果观察组治疗后的血液流变学指标优于对照组,差异有统计学意义(P<0.05)。观察组总有效率93.0%高于对照组的76.7%,差异有统计学意义(P<0.05)。结论低分子肝素钠在肺源性心脏病心力衰竭中的治疗效果显著,值得借鉴。

  7. Clinical efficacy of micro-pump injection of nitroglycerin and sodium nitroprusside in the treatment of hypertensive crisis%静脉微泵注射硝酸甘油与硝普钠治疗高血压危象的效果观察

    Institute of Scientific and Technical Information of China (English)

    朱海龙; 王军; 王英; 梁夷; 张毅

    2012-01-01

    Objective To observe the clinical efficacy of micro-pump injection of nitroglycerin and sodium nitroprusside in the treatment of hypertensive crisis. Methods Sixty-eight patients were randomly divided into two groups, and recieved micro-pump injection of nitroglycerin (group A) or sodium nitroprusside (group B). The clinical efficacy were observed. Results The total effective rate of lowering blood pressure 94.12% in group A and 94.12% in group B, with no statistically significant difference between the two groups (P>0.05). But the duration of the lowering blood pressure was significantly shorter in group B than group A (P<0.05). The effective rate within 30 minutes was 67.65% in group B, but only 26.47% in group A. Conclusion For patients with hypertensive crisis, the clinical effect of sodium nitroglycerin and sodium nitroprusside is similar in lowering blood pressure, but sodium nitroprusside needs significantly shorter duration.%目的 观察静脉微泵注射硝酸甘油与硝普钠在高血压危象患者治疗中的降压效果.方法 68例高血压危象患者随机分成两组,分别行静脉微泵注射硝酸甘油与硝普钠行降压治疗,观察疗效.结果 硝酸甘油组与硝普钠组的降压总有效率相似(94.12%与94.12%,P>0.05),但降压达标时间硝普钠组短于硝酸甘油组(30 min显效率分别为67.65%与26.47%,P<0.05).结论 对于高血压危象患者,两种药物降压效果相似,均可选择.如果需要更快速地控制血压则首选硝普钠.

  8. [Cardiac amyloidosis].

    Science.gov (United States)

    Hoyer, Caroline; Angermann, Christiane E; Knop, Stefan; Ertl, Georg; Störk, Stefan

    2008-03-15

    Amyloidoses are a heterogeneous group of multisystem disorders, which are characterized by an extracellular deposition of amyloid fibrils. Typically affected are the heart, liver, kidneys, and nervous system. More than half of the patients die due to cardiac involvement. Clinical signs of cardiac amyloidosis are edema of the lower limbs, hepatomegaly, ascites and elevated jugular vein pressure, frequently in combination with dyspnea. There can also be chest pain, probably due to microvessel disease. Dysfunction of the autonomous nervous system or arrhythmias may cause low blood pressure, dizziness, or recurrent syncope. The AL amyloidosis caused by the deposition of immunoglobulin light chains is the most common form. It can be performed by monoclonal gammopathy. The desirable treatment therapy consists of high-dose melphalan therapy twice followed by autologous stem cell transplantation. Due to the high peritransplantation mortality, selection of appropriate patients is mandatory. The ATTR amyloidosis is an autosomal dominant disorder caused by the amyloidogenic form of transthyretin, a plasmaprotein that is synthesized in the liver. Therefore, liver transplantation is the only curative therapy. The symptomatic treatment of cardiac amyloidosis is based on the current guidelines for chronic heart failure according to the patient's New York Heart Association (NYHA) state. Further types of amyloidosis with possible cardiac involvement comprise the senile systemic amyloidosis caused by the wild-type transthyretin, secondary amyloidosis after chronic systemic inflammation, and the beta(2)-microglobulin amyloidosis after long-term dialysis treatment. PMID:18344065

  9. Physics of Cardiac Arrhythmogenesis

    Science.gov (United States)

    Karma, Alain

    2013-04-01

    A normal heartbeat is orchestrated by the stable propagation of an excitation wave that produces an orderly contraction. In contrast, wave turbulence in the ventricles, clinically known as ventricular fibrillation (VF), stops the heart from pumping and is lethal without prompt defibrillation. I review experimental, computational, and theoretical studies that have shed light on complex dynamical phenomena linked to the initiation, maintenance, and control of wave turbulence. I first discuss advances made to understand the precursor state to a reentrant arrhythmia where the refractory period of cardiac tissue becomes spatiotemporally disordered; this is known as an arrhythmogenic tissue substrate. I describe observed patterns of transmembrane voltage and intracellular calcium signaling that can contribute to this substrate, and symmetry breaking instabilities to explain their formation. I then survey mechanisms of wave turbulence and discuss novel methods that exploit electrical pacing stimuli to control precursor patterns and low-energy pulsed electric fields to control turbulence.

  10. Inducer pumps for liquid metal reactor plants

    International Nuclear Information System (INIS)

    Pumps proposed for liquid metal reactor plants typically use centrifugal impellers as the rotating element and are required to maintain a relatively low speed to keep the suction specific speed low enough to operate at the available net positive suction head (HPSH) and to avoid cavitation damage. These low speeds of operation require that the pump diameter increase and/or multiple stages be used to achieve the design head. This frequently results in a large, heavy, complex pump design. In addition, the low speed results in a larger drive motor size so that the resultant penalty to the plant designer is multiplied. The heavier pump can also result in further complications as, e.g., the difficulty in maintaining the first critical speed sufficiently above the pump operating range to provide margin for rotor dynamic stability. To overcome some of these disadvantages, it was proposed the use of inducer pumps for Liquid Metal Fast Breeder Reactor (LMFBR) plants. This paper discusses some of the advantages of the inducer pump and the development history of designing and testing these pumps both in water and sodium. The inducer pump is seen to be a sound concept with a strong technology base derived from the aerospace and ship propulsion industries. The superior suction performance capability of the inducer offers significant system design advantages, primarily a smaller, lighter weight, less complex pump design with resulting saving in cost. Extensive testing of these pumps has been conducted in both sodium and water to demonstrate the long-life capability with no cavitation damage occurring in those designs based on Rockwell's current design criteria. These tests have utilized multiple inspection and measurement approaches to accurately assess and identify any potential for cavitation damage, and these approaches have all concluded that no damage is occurring. Therefore, it is concluded that inducer pumps can be safely designed for long life operation in sodium with

  11. Red blood cell sodium transport in patients with cirrhosis

    DEFF Research Database (Denmark)

    Henriksen, Ulrik Lütken; Kiszka-Kanowitz, Marianne; Bendtsen, Flemming;

    2016-01-01

    . Increased RBC sodium efflux is especially related to ouabain-sensitive, furosemide-insensitive transport and thus most likely due to upregulated activity of the sodium-potassium pump. The study gives no evidence to an altered intracellular/extracellular sodium ratio or to a reduced fractional furosemide......Patients with advanced cirrhosis have abnormal sodium homoeostasis. The study was undertaken to quantify the sodium transport across the plasma membrane of red blood cells (RBC) in patients with cirrhosis. RBC efflux and influx of sodium were studied in vitro with tracer (22) Na(+) according......·03-0·007), especially the O-sensitive, F-insensitive efflux was increased (+ 225%, P = 0·01-0·006). Fractional F-sensitive transport was normal in cirrhosis. RBC sodium influx was largely normal in cirrhosis. In conclusion, RBC sodium content is reduced in patients with cirrhosis with a direct relation to serum sodium...

  12. Insulin pumps.

    Science.gov (United States)

    Pickup, J

    2011-02-01

    The last year has seen a continued uptake of insulin pump therapy in most countries. The USA is still a leader in pump use, with probably some 40% of type 1 diabetic patients on continuous subcutaneous insulin infusion (CSII), but the large variation in usage within Europe remains, with relatively high use (> 15%) in, for example, Norway, Austria, Germany and Sweden and low use (companies or funding from national health services, the availability of sufficient diabetes nurse educators and dietitians trained in pump procedures, and clear referral pathways for the pump candidate from general practitioner or general hospital to specialist pump centre. There are now several comprehensive national guidelines on CSII use (see ATTD Yearbook 2009) but more work needs to be done in unifying uptake and ensuring all those who can benefit do so. Technology developments recently include increasing use of pumps with continuous glucose monitoring (CGM) connectivity (see elsewhere in this volume) and the emergence of numerous manufacturers developing so-called 'patch pumps', often for the type 2 diabetes market. Interestingly, the evidence base for CSII in this group is not well established, and for this reason the selected papers on CSII in this section include several in this area. The use of CSII in diabetic pregnancy is a long-established practice, in spite of the lack of evidence that it is superior to multiple daily injections (MDI), and few randomised controlled trials have been done in recent years. Several papers in this field this year continue the debate about the usefulness of CSII in diabetic pregnancy and are reviewed here. It is pleasing to see more research on the psychosocial aspects of CSII during the year, both from the point of view of how psychological beliefs influence outcomes on CSII (is there a type of patient who does particularly well or poorly on CSII?) and how CSII affects psychological factors like mood, behaviour and quality of life. Quality of

  13. Sodium Bicarbonate Therapy in Patients with Metabolic Acidosis

    OpenAIRE

    Adeva-Andany, María M.; Carlos Fernández-Fernández; David Mouriño-Bayolo; Elvira Castro-Quintela; Alberto Domínguez-Montero

    2014-01-01

    Metabolic acidosis occurs when a relative accumulation of plasma anions in excess of cations reduces plasma pH. Replacement of sodium bicarbonate to patients with sodium bicarbonate loss due to diarrhea or renal proximal tubular acidosis is useful, but there is no definite evidence that sodium bicarbonate administration to patients with acute metabolic acidosis, including diabetic ketoacidosis, lactic acidosis, septic shock, intraoperative metabolic acidosis, or cardiac arrest, is beneficial ...

  14. Cardiac rhabdomyosarcoma

    OpenAIRE

    Chlumský, Jaromír; Holá, Dana; Hlaváček, Karel; Michal, Michal; Švec, Alexander; Špatenka, Jaroslav; Dušek, Jan

    2001-01-01

    Cardiac sarcoma is a very rare neoplasm and is difficult to diagnose. The case of a 51-year-old man with a left atrial tumour, locally recurrent three months after its surgical removal, is presented. Computed tomography showed metastatic spread to the lung parenchyma. On revised histology, the mass extirpated was a sarcoma. Because of the metastatic spread, further therapy was symptomatic only; the patient died 15 months after the first manifestation of his problems. Immunohistochemical stain...

  15. Whole blood pumping with a microthrottle pump

    OpenAIRE

    Davies, M J; Johnston, I. D.; Tan, C. K. L.; Tracey, M. C.

    2010-01-01

    We have previously reported that microthrottle pumps (MTPs) display the capacity to pump solid phase suspensions such as polystyrene beads which prove challenging to most microfluidic pumps. In this paper we report employing a linear microthrottle pump (LMTP) to pump whole, undiluted, anticoagulated, human venous blood at 200 μl min−1 with minimal erythrocyte lysis and no observed pump blockage. LMTPs are particularly well suited to particle suspension transport by virtue of their relatively ...

  16. Using a Breast Pump

    Science.gov (United States)

    ... you can relax and not be disturbed while pumping. If you have an electric pump, find an ... otherwise irritating your nipple or breast tissue. Begin Pumping If your pump is electric or battery-powered, ...

  17. Test Your Sodium Smarts

    Science.gov (United States)

    ... You may be surprised to learn how much sodium is in many foods. Sodium, including sodium chloride ... foods with little or no salt. Test your sodium smarts by answering these 10 questions about which ...

  18. Regulation of the Na(+)-K+ pump activity and estimation of the reserve capacity in intact rat peritoneal mast cells

    DEFF Research Database (Denmark)

    Knudsen, Torben; Johansen, Torben

    1990-01-01

    Evidence is provided that regulation of the Na(+)-K+ pump activity in rat peritoneal mast cells occurs mainly through stimulation of the pump from inside the plasma membrane by sodium. It is demonstrated that there is a large reserve capacity for the exchange of intracellular sodium with extracel......Evidence is provided that regulation of the Na(+)-K+ pump activity in rat peritoneal mast cells occurs mainly through stimulation of the pump from inside the plasma membrane by sodium. It is demonstrated that there is a large reserve capacity for the exchange of intracellular sodium with...

  19. Electromagnetic pumping of liquid lithium in inertial confinement fusion reactors

    International Nuclear Information System (INIS)

    The basic operating principles and geometries of ten electromagnetic pumps are described. Two candidate pumps, the annular-linear-induction pump and the helical-rotor electromagnetic pump, are compared for possible use in a full-scale liquid-lithium inertial confinement fusion reactor. A parametric design study completed for the helical-rotor pump is shown to be valid when applied to an experimental sodium pump. Based upon the preliminary HYLIFE requirements for a lithium flow rate per pump of 8.08 m3/s at a head of 82.5 kPa, a complete set of 70 variables are specified for a helical-rotor pump with either a normally conducting or a superconducting winding. The two alternative designs are expected to perform with efficiencies of 50 and 60%, respectively

  20. Multilayer impedance pump: a bio-inspired valveless pump with medical applications

    Science.gov (United States)

    Loumes, Laurence

    This thesis introduces the concept of multilayer impedance pump, a novel pumping mechanism inspired from the embryonic heart structure.The multilayer impedance pump is a composite two-layer fluid-filled elastic tube featuring a thick, gelatin-like internal layer similar in nature to the embryonic cardiac jelly, and that is used to amplify longitudinal elastic waves. Pumping is based on the impedance pumping mechanism. Elastic waves are generated upon small external periodic compressions of the elastic tube. They propagate along the tube's walls, reflect at the tube's extremities and drive the flow in a preferential direction. This fully coupled fluid-structure interaction problem is solved for the flow and the structure using the finite element method over a relevant range of frequencies of excitation. Results show that the two-layer configuration can be an efficient wave propagation combination, and that it allows the pump to produce significant flow for small excitations. The multilayer impedance pump is a complex system in which flow and structure exhibit a resonant behavior. At resonance, a constructive elastic wave interaction coupled with a most efficient energy transmission between the elastic walls and the fluid is responsible for the maximum exit flow. The pump efficiency reaches its highest at resonance, highlighting furthermore the concept of resonance pumping.Using the proposed multilayer impedance pump model, we are able to bring an additional proof on the impedance nature of the embryonic heart by comparing a peristaltic and an impedance multilayer pump both excited in similar fashion to the one observed in the embryonic heart.The gelatin layer that models the embryonic cardiac jelly occupies most of the tube walls and is essential to the propagation of elastic waves. A comparison between the exact same impedance pump with and without the additional gelatin layer sheds light on the dynamic role of the cardiac jelly in the embryonic heart and on nature

  1. Cardiac Hypertrophy: A Review on Pathogenesis and Treatment

    Directory of Open Access Journals (Sweden)

    Ankur Rohilla

    2012-07-01

    Full Text Available Cardiac hypertrophy has been considered as an important risk factor for cardiac morbidity and mortality whose prevalence has increased during the last few decades. Cardiac hypertrophy, a disease associated with the myocardium, is characterized by thickening of ventricle wall of heart and consequent reduction in the contracting ability of heart to pump the blood. Cardiac hypertrophy has been divided into two types, i.e. physiological and pathological hypertrophy. The exercise-induced increase in the ability of pumping blood leads to thickening of ventricle wall, referred to as physiological hypertrophy. On the other hand, reduced ability of pumping blood as a result of hypertension and volume overload on heart denotes pathological hypertrophy. Numerous mediators have been found to be involved in the pathogenesis of cardiac hypertrophy that include mitogen-activated protein kinase (MAPK, protein kinase C (PKC insulin-like growth factor-I (IGF-I, phosphatidylinositol 3-kinase (PI3K-AKT/PKB, calcinurin-nuclear factor of activated T cells (NFAT and mammalian target of rapamycin (mTOR. The prevention strategy for cardiac hypertrophy involve thiazide diuretics, angiotensin-converting enzyme (ACE inhibitors, angiotensin (Ang II receptor blockers, beta blockers and calcium channel blockers. The present review article highlights the signaling mechanisms involved and the approaches required in the treatment of cardiac hypertrophy.

  2. Platelets and cardiac arrhythmia

    Directory of Open Access Journals (Sweden)

    Jonas S De Jong

    2010-12-01

    Full Text Available Sudden cardiac death remains one of the most prevalent modes of death in industrialized countries, and myocardial ischemia due to thrombotic coronary occlusion is its primary cause. The role of platelets in the occurrence of SCD extends beyond coronary flow impairment by clot formation. Here we review the substances released by platelets during clot formation and their arrhythmic properties. Platelet products are released from three types of platelet granules: dense core granules, alpha-granules, and platelet lysosomes. The physiologic properties of dense granule products are of special interest as a potential source of arrhythmic substances. They are released readily upon activation and contain high concentrations of serotonin, histamine, purines, pyrimidines, and ions such as calcium and magnesium. Potential arrhythmic mechanisms of these substances, e.g. serotonin and high energy phosphates, include induction of coronary constriction, calcium overloading, and induction of delayed after-depolarizations. Alpha-granules produce thromboxanes and other arachidonic acid products with many potential arrhythmic effects mediated by interference with cardiac sodium, calcium and potassium channels. Alpha-granules also contain hundreds of proteins that could potentially serve as ligands to receptors on cardiomyocytes. Lysosomal products probably do not have an important arrhythmic effect. Platelet products and ischemia can induce coronary permeability, thereby enhancing interaction with surrounding cardiomyocytes. Antiplatelet therapy is known to improve survival after myocardial infarction. Although an important part of this effect results from prevention of coronary clot formation, there is evidence to suggest that antiplatelet therapy also induces anti-arrhythmic effects during ischemia by preventing the release of platelet activation products.

  3. Continuous analyzers of hydrogen and carbon in liquid sodium and of hydrocarbon total in protective atmosphere above sodium

    International Nuclear Information System (INIS)

    The principle is described of a leak detector for detecting water penetration into sodium in a steam generator. The device operates as a diffusion H-meter with an ion pump. Ni or Fe diffusion diaphragm is washed with sodium while diffused hydrogen is pumped and also monitored with the ion pump. Another detector uses the principle of analyzing hydrocarbons in the cover gas above the sodium level. The carrier gas flow for the analyzer divided into measuring and reference parts is passed through a chamber housing the diffusion standard. For measuring carbon content in sodium, the detector analytical part may be completed with a chamber with moisturizing filling for scrubbing gas. Carbon passing through the diffusion Fe diaphragm is scrubbed on the inner wall in the form of CO which is reduced to methane and measured using the detector C-meter. (M.S.)

  4. Flow Characteristics of the PHTS Mechanical Pump in PGSFR

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jung; Lee, Tae-Hoo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Park, Hwi-Seob [CD-adapco, Seoul (Korea, Republic of)

    2014-10-15

    The PHTS (Primary Heat Transfer System) mechanical pump is one of the most important parts in the PGSFR. The objective of the PHTS pump is to circulate a sodium coolant to transfer the heat generated in the core to the IHTS (Intermediate Heat Transfer System). Therefore, it is important to verify the performance of the PHTS pump under various flow conditions. The flow inside the pump is a very complex multi-dimensional phenomenon that depends on the rotation speed of the pump, and the geometry of the impeller and diffuser. In particular, the pump performance and flow characteristics can be evaluated using a homologous curve represented by normalized variables of the head and torque. Using a homologous curve obtained by a real pump or model pump reduced by the same specific speed is reasonable, but the detailed design procedure about the prototype PHTS pump has not been completed at this point. In this study, the flow characteristics and homologous curve of the PHTS pump are evaluated by CFD. The flow characteristic of the PHTS pump is evaluated by the CFD. The head and torque are calculated at several flow rates and rotation speeds, and these values are substituted with normalized pump parameters. Also, the homologous head and torque curve is plotted using normalized pump parameters. This curve is used as the input of the safety analysis.

  5. Cardiac MRI in Athletes

    NARCIS (Netherlands)

    Luijkx, T.

    2012-01-01

    Cardiac magnetic resonance imaging (CMR) is often used in athletes to image cardiac anatomy and function and is increasingly requested in the context of screening for pathology that can cause sudden cardiac death (SCD). In this thesis, patterns of cardiac adaptation to sports are investigated with C

  6. Pump characteristics and applications

    CERN Document Server

    Volk, Michael

    2013-01-01

    Providing a wealth of information on pumps and pump systems, Pump Characteristics and Applications, Third Edition details how pump equipment is selected, sized, operated, maintained, and repaired. The book identifies the key components of pumps and pump accessories, introduces the basics of pump and system hydraulics as well as more advanced hydraulic topics, and details various pump types, as well as special materials on seals, motors, variable frequency drives, and other pump-related subjects. It uses example problems throughout the text, reinforcing the practical application of the formulae

  7. Discovery of triazolopyridine GS-458967, a late sodium current inhibitor (Late INai) of the cardiac NaV 1.5 channel with improved efficacy and potency relative to ranolazine.

    Science.gov (United States)

    Koltun, Dmitry O; Parkhill, Eric Q; Elzein, Elfatih; Kobayashi, Tetsuya; Notte, Gregory T; Kalla, Rao; Jiang, Robert H; Li, Xiaofen; Perry, Thao D; Avila, Belem; Wang, Wei-Qun; Smith-Maxwell, Catherine; Dhalla, Arvinder K; Rajamani, Sridharan; Stafford, Brian; Tang, Jennifer; Mollova, Nevena; Belardinelli, Luiz; Zablocki, Jeff A

    2016-07-01

    We started with a medium throughput screen of heterocyclic compounds without basic amine groups to avoid hERG and β-blocker activity and identified [1,2,4]triazolo[4,3-a]pyridine as an early lead. Optimization of substituents for Late INa current inhibition and lack of Peak INa inhibition led to the discovery of 4h (GS-458967) with improved anti-arrhythmic activity relative to ranolazine. Unfortunately, 4h demonstrated use dependent block across the sodium isoforms including the central and peripheral nervous system isoforms that is consistent with its low therapeutic index (approximately 5-fold in rat, 3-fold in dog). Compound 4h represents our initial foray into a 2nd generation Late INa inhibitor program and is an important proof-of-concept compound. We will provide additional reports on addressing the CNS challenge in a follow-up communication. PMID:27080178

  8. Intraaortic Balloon Pump Counterpulsation and Cerebral Autoregulation: an observational study

    OpenAIRE

    Boots Rob; Barnett Adrian G; Timms Daniel; Dunster Kimble; Geng Shureng; Bellapart Judith; Fraser John F

    2010-01-01

    Abstract Background The use of Intra-aortic counterpulsation is a well established supportive therapy for patients in cardiac failure or after cardiac surgery. Blood pressure variations induced by counterpulsation are transmitted to the cerebral arteries, challenging cerebral autoregulatory mechanisms in order to maintain a stable cerebral blood flow. This study aims to assess the effects on cerebral autoregulation and variability of cerebral blood flow due to intra-aortic balloon pump and in...

  9. Using a Combined Platform of Swarm Intelligence Algorithms and GIS to Provide Land Suitability Maps for Locating Cardiac Rehabilitation Defibrillators

    OpenAIRE

    KAFFASH-CHARANDABI, Neda; SADEGHI-NIARAKI, Abolghasem; Park, Dong-Kyun

    2015-01-01

    Background: Cardiac arrest is a condition in which the heart is completely stopped and is not pumping any blood. Although most cardiac arrest cases are reported from homes or hospitals, about 20% occur in public areas. Therefore, these areas need to be investigated in terms of cardiac arrest incidence so that places of high incidence can be identi-fied and cardiac rehabilitation defibrillators installed there.Methods: In order to investigate a study area in Petersburg, Pennsylvania State, and...

  10. Activity identification of peptide containing rat sodium pump α2 subunit M1-M2 extramembrane fragment in vitro%大鼠钠泵α2亚单位M1~M2膜外区多肽体外活性鉴定

    Institute of Scientific and Technical Information of China (English)

    张明娟; 杨军; 强磊; 王蓉; 宋亚燔; 牛小麟

    2008-01-01

    本文旨在研究含大鼠钠泵α2亚单位M1~M2膜外区的多肽片段(peptide contmning rat sodium pump α2 subunit M1-M21extramembrane fragment,RES2衍生物)是否具有与内源性钠泵抑制因子结合以及改善钠泵α亚单位活性的作用.采用Fmoc固相合成法合成多肽(Leu-Ala-Ala-Met-Glu-Asp-Glu-Pro-Ser-Asn-Asp-Asn-Gly-Gly-Gly-Ser),产物经高效液相色谱技术纯化,并进行质谱分析.采用放射性配体.受体结合法检测其与哇巴因的结合能力,进而采用人红细胞86Rb摄取实验检测其生物学活性.结果显示,RES2衍生物与3H-哇巴因具有一定的结合能力,其平衡解离常数(Kd)为38.46 nmol/L,IC50为6.353nmol/L.RES2衍生物可以阻断哇巴因对红细胞膜Na+,K+-ATPase的抑制作用,使红细胞86Rb摄取率从38.53%上升到83.69%左右,并呈一定的剂量依赖关系.因此,RES2衍生物不仅具有体外结合活性,而且具有改善钠泵活性的生物学效应,为其成为有效的抗高血压药物提供科学依据.%In order to explore the activity of a peptide containing rat sodium pump α2 subunit M I-M2 extramembrane fragment (RES2derivative) in vitro, the peptide (Len-Ala-Ala-Met-Glu-Asp-Glu-Pro-Ser-Asn-Asp-Asn-Gly-Gly-Gly-Ser) was synthesized by pep-tide synthesizer with Fmoc method and purified by high performance liquid chromatography (HPLC). Its binding activity wasidentified by radioligand-receptor binding assay (RRA) and its bioactivity was measured by erythrocyte 86Rb uptake. The results ofsaturation binding experiment and competitive binding experiment showed that the synthesized RES2 derivative had the capability tobind to 3H-ouabain. The dissociation constant (Kd) was 38.46 nmol/L and IC50 was 6.353 nmol/L. Erythrocyte 86Rb uptake experimentshowed that the RES2 derivative blocked the inhibitory effect of ouabain on the sodium pump on erythrocyte membrane in a dose-dependent manner. The results showed that the RES2 derivative is capable of binding to ouabain and

  11. Minimum-test series for the intermediate-size inducer pump in SPTF at ETEC

    International Nuclear Information System (INIS)

    The overall test program includes pump assembly, installation, testing, removal from the test loop, disassembly and final inspection of the entire pump. Testing will include: checkout tests, head/flow and efficiency characterizations at design and two-loop flow/speed ratios and at selected sodium temperatures; suction performance determination; and a design point endurance test, up to 2000 hours, based on available time. The endurance test will be run at 100 percent NPSH margin. After testing, the pump will be cleaned of sodium, disassembled, and examined to determine the effects of operation at 100 percent NPSH margin for an extended period of time. The testing will be done at Energy Technology Engineering Center (ETEC). Assembly, sodium removal, disassembly, and initial inspection will be performed at Component Handling and Cleaning Facility (CHCF) and sodium testing will be done at Sodium Pump Test Facility

  12. Low sodium level

    Science.gov (United States)

    Low sodium level is a condition in which the amount of sodium (salt) in the blood is lower than normal. ... Sodium is found mostly in the body fluids outside the cells. It is very important for maintaining ...

  13. Sodium and Food Sources

    Science.gov (United States)

    ... Disease Cholesterol High Blood Pressure Million Hearts® WISEWOMAN Sodium and Food Sources Recommend on Facebook Tweet Share ... food [PDF-867K] and how to reduce sodium. Sodium Reduction Is Challenging Types of food matter: More ...

  14. Off-pump CABG surgery reduces systemic inflammation compared with on-pump surgery but does not change systemic endothelial responses : a prospective randomized study

    NARCIS (Netherlands)

    Jongman, Rianne M.; Zijlstra, Jan G.; Kok, Wendelinde F.; van Harten, Annemarie E.; Mariani, Massimo A.; Moser, Jill; Struys, Michel M. R. F.; Absalom, Anthony R.; Molema, Grietje; Scheeren, Thomas W. L.; van Meurs, Matijs

    2014-01-01

    Coronary artery bypass graft (CABG) surgery can result in severe postoperative organ failure. During CABG surgery, cardiopulmonary bypass (CPB) with cardiac arrest is often used (on-pump CABG), which often results in a systemic inflammatory response. To reduce this inflammatory response, off-pump CA

  15. LMFBR with booster pump in pumping loop

    Science.gov (United States)

    Rubinstein, H.J.

    1975-10-14

    A loop coolant circulation system is described for a liquid metal fast breeder reactor (LMFBR) utilizing a low head, high specific speed booster pump in the hot leg of the coolant loop with the main pump located in the cold leg of the loop, thereby providing the advantages of operating the main pump in the hot leg with the reliability of cold leg pump operation.

  16. Isoform-specific Regulation of Sodium pump α-subunit Gene Expression i n Aortic Smooth Muscle Cell of 1-kidney-1-clip Hypertensive Rats%“一肾一夹”高血压大鼠动脉平滑肌细胞钠泵α亚单位的基因表达

    Institute of Scientific and Technical Information of China (English)

    原卫清; 王颢; 吕卓人

    2001-01-01

    Objective To investigate the gene expression of sodium pump α-subunit in aortic smooth muscle of 1-kidney-1-clip (1k1c) hypertensive rats.  Methods 1k1c hypertensive rats were prepared by partially ligating the left renal artery and removing the right kidney. 4 weeks later, all the rats were killed and sodium pump α1- , α2-, and α3-subunit in aortic smooth muscles were detected with reverse transcription p ol ymerase chain reaction (RT-PCR) method and immunohistochemical assay at both mR NA and protein levels, respectively.  Resulsts Changes in the expression of sodi um pump α-subunit gene were found in aortic smooth muscles of 1k1c hypertensiv e rats: α1-su bunit increased at both mRNA protein levels, while α2- and α3-subunits r emained without changes.  Conclusions There were great changes in the gene expression of so dium pump α-subunit in aor tic smooth muscles of 1k1c hypertensive rats, which might be related to the development of hypertension in this hypertensive model.%目的 探讨“一肾一夹(1k1c)”高血压大鼠动脉平滑肌细胞钠泵α亚单位各异构体基 因表达的改变,为高血压发病机制的深入研究提供理论及实验依据。方法 分别应用分子生物学 RT-PCR及免疫组化技术,探讨1k1c高血压大鼠动脉平滑肌细胞钠泵α1、α2及α3亚单位mR NA及蛋白 水平基因表达的改变。结果 1k1c高血压大鼠动脉平滑肌细胞钠泵α亚单位基因表达发生改变: 无论在mRNA或蛋白水平,α1亚单位表达增强,而α2与α3亚单位表达无改变。结论 1k1c高血压大鼠动脉平滑肌细胞钠泵α亚单位基因表达发生改变,这种 改变可能参与了该模型的血压升高 机制。

  17. Heat pump technology

    CERN Document Server

    Von Cube, Hans Ludwig; Goodall, E G A

    2013-01-01

    Heat Pump Technology discusses the history, underlying concepts, usage, and advancements in the use of heat pumps. The book covers topics such as the applications and types of heat pumps; thermodynamic principles involved in heat pumps such as internal energy, enthalpy, and exergy; and natural heat sources and energy storage. Also discussed are topics such as the importance of the heat pump in the energy industry; heat pump designs and systems; the development of heat pumps over time; and examples of practical everyday uses of heat pumps. The text is recommended for those who would like to kno

  18. Cardiac perception and cardiac control. A review.

    Science.gov (United States)

    Carroll, D

    1977-12-01

    The evidence regarding specific cardiac perception and discrimination, and its relationship to voluntary cardiac control, is critically reviewed. Studies are considered in three sections, depending on the method used to assess cardiac perception: questionnaire assessment, discrimination procedures, and heartbeat tracking. The heartbeat tracking procedure would appear to suffer least from interpretative difficulties. Recommendations are made regarding the style of analysis used to assess heartbeat perception in such tracking tasks. PMID:348240

  19. A current-driven nanometer water pump.

    Science.gov (United States)

    Su, Jiaye; Yang, Keda

    2016-03-01

    The design of a water pump, which has huge potential for applications in nanotechnology and daily life, is the dream of many scientists. In this paper, we successfully design a nanometer water pump by using molecular dynamics simulations. Ions of either sodium or chlorine in a narrow channel will generate electric current under electric fields, which then drives the water through a wider channel, similar to recent experimental setups. Considerable water flux is achieved within small field strengths that are accessible by experimentation. Of particular interest, is that for sodium the water flux increases almost linearly with field strengths; while for chlorine there exists a critical field strength, the water flux exhibits a plateau before the critical value and increases linearly after it. This result follows the behavior of ion velocity, which is related to friction behavior. We also estimate the power and energy consumption for such a pump, and compare it to the macroscopic mechanical pumps. A further comparison suggests that different ions will have different pumping abilities. This study not only provides new, significant results with possible connection to existing research, but has tremendous potential application in the design of nanofluidic devices. PMID:26822782

  20. Sodium MRI in human heart: a review.

    Science.gov (United States)

    Bottomley, Paul A

    2016-02-01

    This paper offers a critical review of the properties, methods and potential clinical application of sodium ((23)Na) MRI in human heart. Because the tissue sodium concentration (TSC) in heart is about ~40 µmol/g wet weight, and the (23)Na gyromagnetic ratio and sensitivity are respectively about one-quarter and one-11th of that of hydrogen ((1)H), the signal-to-noise ratio of (23)Na MRI in the heart is about one-6000th of that of conventional cardiac (1)H MRI. In addition, as a quadrupolar nucleus, (23)Na exhibits ultra-short and multi-component relaxation behavior (T1 ~ 30 ms; T2 ~ 0.5-4 ms and 12-20 ms), which requires fast, specialized, ultra-short echo-time MRI sequences, especially for quantifying TSC. Cardiac (23)Na MRI studies from 1.5 to 7 T measure a volume-weighted sum of intra- and extra-cellular components present at cytosolic concentrations of 10-15 mM and 135-150 mM in healthy tissue, respectively, at a spatial resolution of about 0.1-1 ml in 10 min or so. Currently, intra- and extra-cellular sodium cannot be unambiguously resolved without the use of potentially toxic shift reagents. Nevertheless, increases in TSC attributable to an influx of intra-cellular sodium and/or increased extra-cellular volume have been demonstrated in human myocardial infarction consistent with prior animal studies, and arguably might also be seen in future studies of ischemia and cardiomyopathies--especially those involving defects in sodium transport. While technical implementation remains a hurdle, a central question for clinical use is whether cardiac (23)Na MRI can deliver useful information unobtainable by other more convenient methods, including (1)H MRI.

  1. Pre-operative MRI in heart failure patients scheduled for cardiac resynchronization therapy

    NARCIS (Netherlands)

    Manzke, R.; Lutz, A.; Bornstedt , A.; Binner, L.; Merkle, N.; Gradinger, R..; Hombach, V.; Rasche, V.

    2009-01-01

    Cardiac resynchronization therapy (CRT) aims at improving the pumping function of the heart using bi-ventricular pacing. For the lead implantation procedure, knowledge of the heart function, the relevant anatomy (i.e. coro-nary sinus (CS), great cardiac vein (GCV) and its tributaries) and left ventr

  2. Multiple pump housing

    Science.gov (United States)

    Donoho, II, Michael R.; Elliott; Christopher M.

    2010-03-23

    A fluid delivery system includes a first pump having a first drive assembly, a second pump having a second drive assembly, and a pump housing. At least a portion of each of the first and second pumps are located in the housing.

  3. Types of Breast Pumps

    Science.gov (United States)

    ... breast-shield. Some experts discourage the use of bicycle horn pumps because they may be difficult to clean and dry. Battery-Powered and Electric Pumps A powered breast pump uses batteries or a cord plugged into an electrical outlet to power a small motorized pump that ...

  4. Danaparoid sodium.

    Science.gov (United States)

    Acostamadiedo, J M; Iyer, U G; Owen, J

    2000-05-01

    Danaparoid sodium (Orgaran, Organon) is a heparinoid glycosamino-glycuronan antithrombotic agent approved for the prophylaxis of post-operative deep vein thrombosis (DVT), which may lead to pulmonary embolism (PE) in patients undergoing elective hip replacement surgery. Danaparoid is a low molecular weight heparinoid consisting of a mixture of heparan sulphate (84%), dermatan sulphate (12%) and small amounts of chondroitin sulphate (4%), whose antithrombotic activity has been well established. Its pharmacological effect is exerted primarily by inhibiting Factors Xa (FXa) and IIa (FIIa) at a ratio greater than heparin, with a minimal effect on platelet function. Danaparoid exhibits low cross-reactivity with heparin-induced antibodies when compared with heparin or low molecular weight heparins (LMWH), thereby making it an excellent choice for the management of heparin-induced thrombocytopenia (HIT). It has excellent bioavailability following s.c. injection. Danaparoid has little effect on routine coagulation tests (activated partial thromboplastin time [aPTT], prothrombin time [PT], and thrombin time [TT]). Patients with elevated serum creatinine should be monitored carefully. For its FDA approved indication (DVT prophylaxis during hip replacement surgery), its cost per day is approximately eight times more than LMWH. Even though monitoring is not routinely necessary according to the manufacturer for its approved indication, monitoring is frequently necessary when it is used in other clinical scenarios. Its higher cost than comparable therapies for DVT prophylaxis and the low availability of the FXa assay in most non-tertiary care hospitals has limited the widespread use of danaparoid. Danaparoid has been found to be effective in the treatment of HIT although this is an off label use, despite being the most frequent reason why danaparoid is used. PMID:11249517

  5. 哇巴因与地高辛对大鼠心肌钠泵α亚单位基因表达影响的对比研究%Effects of ouabain and digoxin on gene expression of sodium pump α-subunit isoforms in rat myocardium

    Institute of Scientific and Technical Information of China (English)

    王颢; 原卫清; 吕卓人

    2001-01-01

    Objective To compare the effects of ouabain and digoxin on the gene expression of sodium pump α-subunit isoforms in the myocardium of rats. Methods Normal Sprague-Dawley (SD) rats were injected with ouabain (20 μg· kg-1· d-1, i.p. ), digoxin (32 μg· kg-1· d-1, i.p. ) and normal saline (NS) once a day, respectively, and indirect systolic blood pressure was recorded once a week. Six weeks later, all of the rats were killed, and sodium pump α1-, α2-, and α3-subunit mRNA levels in the myocardium were detected with the reverse transcription polymerase chain reaction (RT-PCR) method. Results The systolic blood pressure of the rats infused with ouabain increased significantly at the end of week 6 ( 132.6 ± 9.0 mm Hg vs 115.7 ± 8.2 mm Hg, P < 0.01 ), while no difference in blood pressure was found between the digoxin group and the NS group. The expression of sodium pump α-subunit isoforms in the ventricular myocardium was regulated by either ouabain or digoxin. Both ouabain and digoxin stimulated expression of the α3-isoform, whereas o2 was uncharcged in those two groups. α1-isoform expression decreased in the ouabain group and was unchanged in the digoxin group. Conclusions These results suggest that both ouabain and digoxin could regulate sodium pump α-subunit isoform expression, which might be related to the physiological roles of endogenous ouabain and might be responsible for the difference in the pharmacological and toxicological effects of ouabain and digoxin, including their effects on blood pressure.%目的对比研究哇巴因与地高辛对大鼠心肌钠泵(Na+,K+-ATP酶)亚单位基因表达的影响,探讨内源性 哇巴因(EO)的生物学效应以及洋地黄类药物药理作用的分子机制。 方法每天给予大鼠注射小剂量哇巴因(20μg·kg-1·d-1)与地高辛(32μg·kg-1·d-1),每周测量一次大鼠血 压;6周后处死动物,应用RT-PCR技术在mRNA水平探讨大鼠心肌钠泵α1、α2及α3

  6. Centrifugal pump handbook

    CERN Document Server

    Pumps, Sulzer

    2010-01-01

    This long-awaited new edition is the complete reference for engineers and designers working on pump design and development or using centrifugal pumps in the field. This authoritative guide has been developed with access to the technical expertise of the leading centrifugal pump developer, Sulzer Pumps. In addition to providing the most comprehensive centrifugal pump theory and design reference with detailed material on cavitation, erosion, selection of materials, rotor vibration behavior and forces acting on pumps, the handbook also covers key pumping applications topics and operational

  7. Diffuse infiltrative cardiac tuberculosis

    International Nuclear Information System (INIS)

    We present the cardiac magnetic resonance images of an unusual form of cardiac tuberculosis. Nodular masses in a sheet-like distribution were seen to infiltrate the outer myocardium and pericardium along most of the cardiac chambers. The lesions showed significant resolution on antitubercular therapy

  8. Sodium removal from sodium wetted under sodium ultra sonic scanner

    International Nuclear Information System (INIS)

    Highlights: ► Sodium wetted USUSS was subjected to sodium cleaning by water vapour–CO2 process. ► Hydrogen released during the process was monitored and regulated in safe limit. ► The temperature of USUSS was maintained below 80 °C to prevent caustic corrosion. ► The experiment revealed intricacies involved in the cleaning operation. ► The operational parameters for safe cleaning were optimised. - Abstract: Sodium is used as a coolant in primary and secondary heat transport systems of Liquid Metal cooled Fast Breeder Reactors (LMFBR). The Prototype Fast Breeder Reactor (PFBR) is in advanced stage of construction at Kalpakkam, India. Under Sodium Ultra Sonic Scanner (USUSS) is used to image the components dipped in sodium and more specifically the gap between Sub Assembly (SA) heads and the control plug. This is essential to confirm that no SA is protruding from its position. USUSS has to be qualified in sodium before its use in the reactor. After sodium testing, sodium adhering to the USUSS needs to be removed to prevent reaction with oxygen and moisture present in air when it is taken out. The sodium removal process is based on the use of moist carbon-di-oxide (CO2) at a temperature of about 353 K. The reaction rate is controlled by varying the ratio of CO2 to moisture. Hydrogen released during the reaction of sodium with moisture is continuously monitored to ensure safe limits of hydrogen concentration. This paper describes the details of the experimental setup used in a cleaning pit for the removal of sodium adhering on USUSS and the technical details of the cleaning process.

  9. The safety of proton pump inhibitors in pregnancy

    DEFF Research Database (Denmark)

    Nielsen, Gunnar Lauge; Sørensen, Henrik Toft; Thulstrup, Ane Marie;

    1999-01-01

    on The Pharmaco-Epidemiological Prescription Database of North Jutland and the Danish Hospital Discharge Registry. RESULTS: Three babies with malformations were found among 38 women exposed to proton pump inhibitors from 30 days before conception to the end of the first trimester. No cases of stillbirth were...... birth weight or number of preterm deliveries in pregnancies exposed to proton pump inhibitors. However, further monitoring is warranted in order to establish or rule out a potential association between the use of proton pump inhibitors and increased risk of either cardiac malformations or preterm birth....

  10. In vivo evaluation of centrifugal blood pump for cardiopulmonary bypass-Spiral Pump.

    Science.gov (United States)

    da Silva, Cibele; da Silva, Bruno Utiyama; Leme, Juliana; Uebelhart, Beatriz; Dinkhuysen, Jarbas; Biscegli, José F; Andrade, Aron; Zavaglia, Cecília

    2013-11-01

    The Spiral Pump (SP), a centrifugal blood pump for cardiopulmonary bypass (CPB), has been developed at the Dante Pazzanese Institute of Cardiology/Adib Jatene Foundation laboratories, with support from Sintegra Company (Pompeia, Brazil). The SP is a disposable pump with an internal rotor-a conically shaped fuse with double entrance threads. This rotor is supported by two ball bearings, attached to a stainless steel shaft fixed to the housing base. Worm gears provide axial motion to the blood column, and the rotational motion of the conically shaped impeller generates a centrifugal pumping effect, improving pump efficiency without increasing hemolysis. In vitro tests were performed to evaluate the SP's hydrodynamic performance, and in vivo experiments were performed to evaluate hemodynamic impact during usual CPB. A commercially available centrifugal blood pump was used as reference. In vivo experiments were conducted in six male pigs weighing between 60 and 90 kg, placed on CPB for 6 h each. Blood samples were collected just before CPB (T0) and after every hour of CPB (T1-T6) for hemolysis determination and laboratory tests (hematological and biochemical). Values of blood pressure, mean flow, pump rotational speed, and corporeal temperature were recorded. Also, ergonomic conditions were recorded: presence of noise, difficulty in removing air bubbles, trouble in installing the pump in the drive module (console), and difficulties in mounting the CPB circuit. Comparing the laboratory and hemolysis results for the SP with those of the reference pump, we can conclude that there is no significant difference between the two devices. In addition, reports made by medical staff and perfusionists described a close similarity between the two devices. During in vivo experiments, the SP maintained blood flow and pressure at physiological levels, consistent with those applied in cardiac surgery with CPB, without presenting any malfunction. Also, the SP needed lower rotational

  11. The role of cell savers and filters in cardiac surgery

    NARCIS (Netherlands)

    Vermeijden, Jan Wytze

    2015-01-01

    This thesis investigates the different possibilities of blood sparing strategies in routine cardiac on pump surgery. Reducing allogeneic blood transfusions can improve patient outcome. The main focus of the thesis is on methods of improving shed and cardiotomy blood by filtration with the use of leu

  12. Short review of sodium removal experience in PNC

    International Nuclear Information System (INIS)

    Experiences in the removal of sodium from fuel assemblies and other reactor components are shortly reviewed. The experiences were obtained from the operation of the FBR ''JOYO'' and at the research work facilities in the O-arai Engineering Center, PNC. As for JOYO, many dummy fuel and blanket fuel sub-assemblies and dummy control rods have been sent to the Fuel Cleaning Facility for sodium removal. Steam and demineralized water have been used for the process. Sodium removal from the grapples of the fuel handling machines was done after a certain time of service in sodium. For this process, alcohol has been used. Sodium removal from the mechanical sodium pump of the primary coolant system was done with steam-nitrogen and water. At the research work facilities, on the other hand, sodium removal tests were performed for various components, such as the secondary mockup pump of JOYO, 1 MW steam generator, sector model of the intermediate heat exchanger of JOYO, and mockup isolation valves. From these experiences, it was found that sodium removal from small crevices by conventional methods was difficult. In order to improve this situation, saturation boiling process was designed, and the experiment using test pieces has been initiated. This process is modification of the water charging process, in which water is charged into the process cell or tank and the inside pressure is adjusted so that boiling of the water is initiated and the formation of hydroxide film is prevented. (Aoki, K.)

  13. Hemodynamic and neuroendocrine responses to changes in sodium intake in compensated heart failure

    DEFF Research Database (Denmark)

    Damgaard, Morten; Norsk, Peter; Gustafsson, Finn;

    2006-01-01

    Patients with untreated heart failure (HF) exhibit a blunted hemodynamic and neuroendocrine response to a high sodium intake, leading to excessive sodium and water retention. However, it is not known whether this is the case for patients with compensated HF receiving angiotensin-converting enzyme....... In conclusion, high sodium intake was tolerated without any excessive sodium and water retention in medically treated patients with compensated HF. The observation that high sodium intake improves cardiac performance, induces peripheral vasodilatation, and suppresses the release of vasoconstrictor hormones does......-state conditions, hemodynamic and neuroendocrine examinations were performed at rest and during bicycle exercise. In seated HF patients, high sodium intake increased body weight (1.6 +/- 0.4%), plasma volume (9 +/- 2%), cardiac index (14 +/- 6%), and stroke volume index (21 +/- 5%), whereas mean arterial pressure...

  14. Hemodynamic and neuroendocrine responses to changes in sodium intake in compensated heart failure

    DEFF Research Database (Denmark)

    Damgaard, Morten; Norsk, Peter; Gustafsson, Finn;

    2005-01-01

    Patients with untreated heart failure (HF) exhibit a blunted hemodynamic and neuroendocrine response to a high sodium intake, leading to excessive sodium and water retention. However, it is not known whether this is the case for patients with compensated HF receiving angiotensin-converting enzyme....... In conclusion, high sodium intake was tolerated without any excessive sodium and water retention in medically treated patients with compensated HF. The observation that high sodium intake improves cardiac performance, induces peripheral vasodilatation, and suppresses the release of vasoconstrictor hormones does......-state conditions, hemodynamic and neuroendocrine examinations were performed at rest and during bicycle exercise. In seated HF patients, high sodium intake increased body weight (1.6 +/- 0.4%), plasma volume (9 +/- 2%), cardiac index (14 +/- 6%), and stroke volume index (21 +/- 5%), whereas mean arterial pressure...

  15. Potential and limits of sodium hydroxide as an additive to the binary system ammonia/water in absorption heat pumps; Potenzial und Grenzen von Natriumhydroxid als Zusatz zum Stoffpaar Ammoniak/Wasser in Absorptions-Waermepumpen

    Energy Technology Data Exchange (ETDEWEB)

    Kotenko, Oleksandr; Moser, Harald; Fenzl, Thomas; Rieberer, Rene [Technische Univ. Graz (Austria). Inst. fuer Waermetechnik

    2011-07-01

    Several authors proposed the use of sodium hydroxide (NaOH) as an additive to the ammonia/water working fluid mixture (NH{sub 3} / H{sub 2}O), especially in solar air conditioners. Measured vapour-liquid equilibrium data of this tertiary mixture are found in the relevant literature. Thermodynamic calculations carried out with these data show that the efficiency (COP) will be enhanced in theory while the rectification time will decrease. To verify these theoretical considerations and to gain practical experience with the tertiary mixture NH{sub 3} / H{sub 2}O / NaOH, a test stand was constructed at the Institut fuer Waermetechnik, and measurements were carried out on the mixture NH{sub 3} / H{sub 2}O, i.e. without NaOH, and with 5% NaOH. The technical feasibility of the process was established, although NaOH depositions in the refrigerating circuit caused operational disturbances, so that the mixture had to be renewed regularly and the plant had to be flushed with water. The expected efficiency improvement was not observed. Analyses using ''ASPEN Plus'' showed that this was the result of lower absorber efficiency, which may be due to the higher circulation rate and higher viscosity of the working fluid mixture. Measurements showed a moderate improvements of heat transfer in the expeller after addition of NaOH; no effects were found in the evaporator, solvent heat exchanger and rectification column. The findings suggest that fast implementation of NH{sub 3} / H{sub 2}O / NaOH-AWP is not realistic. Considerable research and development will still be required for optimisation of the absorber for operation with NaOH. [German] Die Verwendung von Natriumhydroxid (NaOH) als Zusatz zum Arbeitsstoffgemisch Ammoniak / Wasser (NH{sub 3} / H{sub 2}O) wurde von verschiedenen Autoren insbesondere fuer das Anwendungsgebiet der solaren Klimatisierung vorgeschlagen. In der einschlaegigen Literatur wurden gemessene Dampf-Fluessig-Gleichgewichts-Daten von diesem

  16. Use of danaparoid sodium (Orgaran) as an alternative to heparin sodium during cardiopulmonary bypass: a clinical evaluation of six cases.

    Science.gov (United States)

    Fernandes, P; Mayer, R; MacDonald, J L; Cleland, A G; Hay-McKay, C

    2000-11-01

    Heparin-induced thrombocytopenia (HIT) has become more prevalent in today's cardiac setting and has resulted in the need for alternative anticoagulant therapies. Danaparoid sodium, one alternative to heparin, has been used in six cardiopulmonary bypass procedures in this hospital. This clinical experience has resulted in the progressive refinement of a protocol for the 'safe' clinical use of danaparoid sodium. Although there were six positive outcomes with the use of danaparoid sodium, alternatives must be explored in order to find the optimal anticoagulant for the treatment of HIT. PMID:11131218

  17. Cardiac tumours in children

    Directory of Open Access Journals (Sweden)

    Parsons Jonathan M

    2007-03-01

    Full Text Available Abstract Cardiac tumours are benign or malignant neoplasms arising primarily in the inner lining, muscle layer, or the surrounding pericardium of the heart. They can be primary or metastatic. Primary cardiac tumours are rare in paediatric practice with a prevalence of 0.0017 to 0.28 in autopsy series. In contrast, the incidence of cardiac tumours during foetal life has been reported to be approximately 0.14%. The vast majority of primary cardiac tumours in children are benign, whilst approximately 10% are malignant. Secondary malignant tumours are 10–20 times more prevalent than primary malignant tumours. Rhabdomyoma is the most common cardiac tumour during foetal life and childhood. It accounts for more than 60% of all primary cardiac tumours. The frequency and type of cardiac tumours in adults differ from those in children with 75% being benign and 25% being malignant. Myxomas are the most common primary tumours in adults constituting 40% of benign tumours. Sarcomas make up 75% of malignant cardiac masses. Echocardiography, Computing Tomography (CT and Magnetic Resonance Imaging (MRI of the heart are the main non-invasive diagnostic tools. Cardiac catheterisation is seldom necessary. Tumour biopsy with histological assessment remains the gold standard for confirmation of the diagnosis. Surgical resection of primary cardiac tumours should be considered to relieve symptoms and mechanical obstruction to blood flow. The outcome of surgical resection in symptomatic, non-myxomatous benign cardiac tumours is favourable. Patients with primary cardiac malignancies may benefit from palliative surgery but this approach should not be recommended for patients with metastatic cardiac tumours. Surgery, chemotherapy and radiotherapy may prolong survival. The prognosis for malignant primary cardiac tumours is generally extremely poor.

  18. The abdominal circulatory pump.

    Directory of Open Access Journals (Sweden)

    Andrea Aliverti

    Full Text Available Blood in the splanchnic vasculature can be transferred to the extremities. We quantified such blood shifts in normal subjects by measuring trunk volume by optoelectronic plethysmography, simultaneously with changes in body volume by whole body plethysmography during contractions of the diaphragm and abdominal muscles. Trunk volume changes with blood shifts, but body volume does not so that the blood volume shifted between trunk and extremities (Vbs is the difference between changes in trunk and body volume. This is so because both trunk and body volume change identically with breathing and gas expansion or compression. During tidal breathing Vbs was 50-75 ml with an ejection fraction of 4-6% and an output of 750-1500 ml/min. Step increases in abdominal pressure resulted in rapid emptying presumably from the liver with a time constant of 0.61+/-0.1SE sec. followed by slower flow from non-hepatic viscera. The filling time constant was 0.57+/-0.09SE sec. Splanchnic emptying shifted up to 650 ml blood. With emptying, the increased hepatic vein flow increases the blood pressure at its entry into the inferior vena cava (IVC and abolishes the pressure gradient producing flow between the femoral vein and the IVC inducing blood pooling in the legs. The findings are important for exercise because the larger the Vbs the greater the perfusion of locomotor muscles. During asystolic cardiac arrest we calculate that appropriate timing of abdominal compression could produce an output of 6 L/min. so that the abdominal circulatory pump might act as an auxiliary heart.

  19. Large electromagnetic pumps. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Kilman, G.B.

    1976-01-01

    The development of large electromagnetic pumps for the liquid metal heat transfer systems of fission reactors has progressed for a number of years. Such pumps are now planned for fusion reactors and solar plants as well. The Einstein-Szilard (annular) pump has been selected as the preferred configuration. Some of the reasons that electromagnetic pumps may be preferred over mechanical pumps and why the annular configuration was selected are discussed. A detailed electromagnetic analysis of the annular pump, based on slug flow, is presented. The analysis is then used to explore the implications of large size and power on considerations of electromagnetic skin effect, geometric skin effect and the cylindrical geometry.

  20. Experience with the Sarns centrifugal pump in postcardiotomy ventricular failure.

    Science.gov (United States)

    Curtis, J J; Walls, J T; Schmaltz, R; Boley, T M; Nawarawong, W; Landreneau, R J

    1992-09-01

    The reported clinical use of the Sarns centrifugal pump (Sarns, Inc./3M, Ann Arbor, Mich.) as a cardiac assist device for postcardiotomy ventricular failure is limited. During a 25-month period ending November 1988, we used 40 Sarns centrifugal pumps as univentricular or biventricular cardiac assist devices in 27 patients who could not be weaned from cardiopulmonary bypass despite maximal pharmacologic and intraaortic balloon support. Eighteen men and nine women with a mean age of 60.4 years (28 to 83) required assistance. Left ventricular assist alone was used in 12 patients, right ventricular assist in 2, and biventricular assist in 13. The duration of assist ranged from 2 to 434 hours (median 45). Centrifugal assist was successful in weaning 100% of the patients. Ten of 27 patients (37%) improved hemodynamically, allowing removal of the device(s), and 5 of 27 (18.5%) survived hospitalization. Survival of patients requiring left ventricular assist only was 33.3% (4/12). Complications were common and included renal failure, hemorrhage, coagulopathy, ventricular arrhythmias, sepsis, cerebrovascular accident, and wound infection. During 3560 centrifugal pump hours, no pump thrombosis was observed. The Sarns centrifugal pump is an effective assist device when used to salvage patients who otherwise cannot be weaned from cardiopulmonary bypass. Statistical analysis of preoperative patient characteristics, operative risk factors, and postoperative complications failed to predict which patients would be weaned from cardiac assist or which would survive.

  1. ECLS in Pediatric Cardiac Patients

    Science.gov (United States)

    Di Nardo, Matteo; MacLaren, Graeme; Marano, Marco; Cecchetti, Corrado; Bernaschi, Paola; Amodeo, Antonio

    2016-01-01

    Extracorporeal life support (ECLS) is an important device in the management of children with severe refractory cardiac and or pulmonary failure. Actually, two forms of ECLS are available for neonates and children: extracorporeal membrane oxygenation (ECMO) and use of a ventricular assist device (VAD). Both these techniques have their own advantages and disadvantages. The intra-aortic balloon pump is another ECLS device that has been successfully used in larger children, adolescents, and adults, but has found limited applicability in smaller children. In this review, we will present the “state of art” of ECMO in neonate and children with heart failure. ECMO is commonly used in a variety of settings to provide support to critically ill patients with cardiac disease. However, a strict selection of patients and timing of intervention should be performed to avoid the increase in mortality and morbidity of these patients. Therefore, every attempt should be done to start ECLS “urgently” rather than “emergently,” before the presence of dysfunction of end organs or circulatory collapse. Even though exciting progress is being made in the development of VADs for long-term mechanical support in children, ECMO remains the mainstay of mechanical circulatory support in children with complex anatomy, particularly those needing rapid resuscitation and those with a functionally univentricular circulation. With the increase in familiarity with ECMO, new indications have been added, such as extracorporeal cardiopulmonary resuscitation (ECPR). The literature supporting ECPR is increasing in children. Reasonable survival rates have been achieved after initiation of support during active compressions of the chest following in-hospital cardiac arrest. Contraindications to ECLS have reduced in the last 5 years and many centers support patients with functionally univentricular circulations. Improved results have been recently achieved in this complex subset of patients. PMID

  2. Stimulating endogenous cardiac regeneration

    Directory of Open Access Journals (Sweden)

    Amanda eFinan

    2015-09-01

    Full Text Available The healthy adult heart has a low turnover of cardiac myocytes. The renewal capacity, however, is augmented after cardiac injury. Participants in cardiac regeneration include cardiac myocytes themselves, cardiac progenitor cells, and peripheral stem cells, particularly from the bone marrow compartment. Cardiac progenitor cells and bone marrow stem cells are augmented after cardiac injury, migrate to the myocardium, and support regeneration. Depletion studies of these populations have demonstrated their necessary role in cardiac repair. However, the potential of these cells to completely regenerate the heart is limited. Efforts are now being focused on ways to augment these natural pathways to improve cardiac healing, primarily after ischemic injury but in other cardiac pathologies as well. Cell and gene therapy or pharmacological interventions are proposed mechanisms. Cell therapy has demonstrated modest results and has passed into clinical trials. However, the beneficial effects of cell therapy have primarily been their ability to produce paracrine effects on the cardiac tissue and recruit endogenous stem cell populations as opposed to direct cardiac regeneration. Gene therapy efforts have focused on prolonging or reactivating natural signaling pathways. Positive results have been demonstrated to activate the endogenous stem cell populations and are currently being tested in clinical trials. A potential new avenue may be to refine pharmacological treatments that are currently in place in the clinic. Evidence is mounting that drugs such as statins or beta blockers may alter endogenous stem cell activity. Understanding the effects of these drugs on stem cell repair while keeping in mind their primary function may strike a balance in myocardial healing. To maximize endogenous cardiac regeneration,a combination of these approaches couldameliorate the overall repair process to incorporate the participation ofmultiple cell players.

  3. Proton pump inhibitors

    Science.gov (United States)

    Proton pump inhibitors (PPIs) are medicines that work by reducing the amount of stomach acid made by ... Proton pump inhibitors are used to: Relieve symptoms of acid reflux, or gastroesophageal reflux disease (GERD). This ...

  4. Padronização da dose de heparina sódica utilizada na cirurgia de revascularização do miocárdio sem circulação extracorpórea Standardization of the sodium heparin dose used in off-pump myocardial revascularization surgery

    Directory of Open Access Journals (Sweden)

    José Glauco Lobo Filho

    2005-09-01

    Full Text Available OBJETIVO: Propor uma metodologia de anticoagulação com heparina sódica monitorizada pelo Tempo de Coagulação Ativada (TCA nos pacientes submetidos à cirurgia de revascularização miocárdica (RM sem circulação extracorpórea (CEC, que promova uma anticoagulação segura (TCA >200 segundos, utilizando uma dose inicial de 1mg heparina sódica/kg de peso. MÉTODO: Quarenta pacientes (30 homens e 10 mulheres, entre 41 e 85 anos, foram submetidos à cirurgia de RM sem CEC, utilizando uma dose inicial de 1mg heparina sódica/kg de peso. Dez minutos após a administração da droga, quando TCA > 200 segundos, iniciava-se a confecção das anastomoses coronarianas. Caso contrário, administrava-se 0,5mg/kg de heparina suplementar. Durante a cirurgia, a cada 30 minutos, novos valores de TCA foram obtidos. Concluídas as anastomoses coronarianas, a heparina foi revertida na proporção de 1:1 utilizando cloridrato de protamina. RESULTADOS: O valor médio de TCA dez minutos pós-heparinização foi de 372,2(+/-104,31 segundos, sem variação estatisticamente significante entre os sexos ou grupos etários (p>0,05. Os valores de TCA, 30 e 60 minutos pós-heparinização, mantiveram-se acima de 200 segundos. Aos 30 minutos, verificou-se diferença estatisticamente significante dos valores do TCA entre os sexos e diferentes idades (pOBJECTIVE: To evaluate a methodology of anticoagulation during off pump coronary artery bypass surgery (CABS that promotes safe anticoagulation during the procedure (Activated Coagulation Time >200 seconds, using an initial dose of 1 mg of sodium heparin/kg weight. METHOD: 40 patients (30 men and 10 women, ages ranging from 41 to 85 years, were submitted to off pump CABS, using an initial sodium heparin dose of 1mg/kg of weight. Ten minutes after that drug was administered, if the ACT was > 200 seconds, we initiated the revascularization procedure. If not, we administered an additional of 0.5mg/kg heparin. During the

  5. Photovoltaic pump systems

    Science.gov (United States)

    Klockgether, J.; Kiessling, K. P.

    1983-09-01

    Solar pump systems for the irrigation of fields and for water supply in regions with much sunshine are discussed. For surface water and sources with a hoisting depth of 12 m, a system with immersion pumps is used. For deep sources with larger hoisting depths, an underwater motor pump was developed. Both types of pump system meet the requirements of simple installation and manipulation, safe operation, maintenance free, and high efficiency reducing the number of solar cells needed.

  6. Docusate Sodium and Pregnancy

    Science.gov (United States)

    ... live chat Live Help Fact Sheets Share Docusate Sodium Friday, 01 April 2016 In every pregnancy, a ... This sheet talks about whether exposure to docusate sodium may increase the risk for birth defects over ...

  7. Diclofenac sodium overdose

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/002630.htm Diclofenac sodium overdose To use the sharing features on this page, please enable JavaScript. Diclofenac sodium is a prescription medicine used to relieve pain ...

  8. Naproxen sodium overdose

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/002507.htm Naproxen sodium overdose To use the sharing features on this page, please enable JavaScript. Naproxen sodium is a nonsteroidal anti-inflammatory drug (NSAID) used ...

  9. Pump for Saturated Liquids

    Science.gov (United States)

    Elliott, D. G.

    1986-01-01

    Boiling liquids pumped by device based on proven components. Expanding saturated liquid in nozzle and diverting its phases along separate paths in liquid/vapor separator raises pressure of liquid. Liquid cooled in process. Pump makes it unnecessary to pressurize cryogenic liquids in order to pump them. Problems of introducing noncondensable pressurizing gas avoided.

  10. Breast milk - pumping and storing

    Science.gov (United States)

    ... a comfortable chair, sink, and electric pump. If pumping at work is going to be hard, build ... up your milk supply. Wash your hands before pumping. Collect breast milk when pumping. You can use: ...

  11. Differential regulation of sodium pump α-subunit isoform gene by ouabain and digoxin in myocardium of rats%巴因与地高辛对大鼠心肌钠泵α亚单位 哇巴因与地高辛对大鼠心肌钠泵α亚单位基因表达影响的研究

    Institute of Scientific and Technical Information of China (English)

    原卫清; 王颢; 吕卓人

    2001-01-01

    目的 对比研究哇巴因与地高辛对大鼠心肌钠泵(Na+-K+-ATP酶)α亚单位基因表达的影响。方法 长期给予大鼠注射小剂量哇巴因(20 μg*kg-1*d-1)与地高辛(32 μg*kg-1*d-1),分别应用分子生物学RT-PCR及免疫组织化学技术分析大鼠心肌钠泵α1、α2及α3亚单位mRNA及蛋白水平基因表达的改变。结果 长期给予大鼠注射小剂量哇巴因可使大鼠血压升高,而地高辛对大鼠血压无影响。无论是在mRNA水平还是在蛋白水平,哇巴因组大鼠心肌钠泵α1亚单位表达减弱,α3亚单位表达增强,而α2亚单位表达无改变;地高辛组大鼠心肌钠泵α3亚单位表达增强,而α1与α2亚单位表达无改变。结论 哇巴因在高血压发病中可能起着重要作用;哇巴因与地高辛可导致不同的钠泵基因表达改变。%Objective To compare the effects of ouabain and digoxin on both the systolic blood pressure (SBP) and sodium pump α-subunit expression in myocardium of rats. Methods Normal Sprague-Dawley (SD) rats were injected with ouabain, digoxin or normal saline (NS) everyday and indirect SBP was recorded once a week. Six weeks later, all the rats were killed and sodium pump α1-, α2-, and α3-subunit were detected in the left ventricular myocardium with RT-PCR method and immunohistochemical assay at mRNA and protein levels. Results At the end of six weeks SBP of rats infused with ouabain increased significantly (132.6±9.0 vs 115.7±8.2 mm Hg, P<0.01), while no difference of SBP was found between digoxin group and NS group. The effects of ouabain and digoxin on sodium pump α-subunit isoform expression in myocardium were also different: both ouabain and digoxin stimulated expression of α3-isoform whereas α2-isoform unchanged at both mRNA and protein levels. α1-isoform was decreased in ouabain group and α1-isoform unchanged in digoxin group at both mRNA and protein levels. Conclusion It is suggested

  12. Marketing cardiac CT programs.

    Science.gov (United States)

    Scott, Jason

    2010-01-01

    There are two components of cardiac CT discussed in this article: coronary artery calcium scoring (CACS) and coronary computed tomography angiography (CCTA).The distinctive advantages of each CT examination are outlined. In order to ensure a successful cardiac CT program, it is imperative that imaging facilities market their cardiac CT practices effectively in order to gain a competitive advantage in this valuable market share. If patients receive quality care by competent individuals, they are more likely to recommend the facility's cardiac CT program. Satisfied patients will also be more willing to come back for any further testing.

  13. Anion channelrhodopsins for inhibitory cardiac optogenetics.

    Science.gov (United States)

    Govorunova, Elena G; Cunha, Shane R; Sineshchekov, Oleg A; Spudich, John L

    2016-01-01

    Optical control of the heart muscle is a promising strategy for cardiology because it is more specific than traditional electrical stimulation, and allows a higher temporal resolution than pharmacological interventions. Anion channelrhodopsins (ACRs) from cryptophyte algae expressed in cultured neonatal rat ventricular cardiomyocytes produced inhibitory currents at less than one-thousandth of the light intensity required by previously available optogenetic tools, such as the proton pump archaerhodopsin-3 (Arch). Because of their greater photocurrents, ACRs permitted complete inhibition of cardiomyocyte electrical activity under conditions in which Arch was inefficient. Most importantly, ACR expression allowed precisely controlled shortening of the action potential duration by switching on the light during its repolarization phase, which was not possible with previously used optogenetic tools. Optical shortening of cardiac action potentials may benefit pathophysiology research and the development of optogenetic treatments for cardiac disorders such as the long QT syndrome. PMID:27628215

  14. Anion channelrhodopsins for inhibitory cardiac optogenetics

    Science.gov (United States)

    Govorunova, Elena G.; Cunha, Shane R.; Sineshchekov, Oleg A.; Spudich, John L.

    2016-01-01

    Optical control of the heart muscle is a promising strategy for cardiology because it is more specific than traditional electrical stimulation, and allows a higher temporal resolution than pharmacological interventions. Anion channelrhodopsins (ACRs) from cryptophyte algae expressed in cultured neonatal rat ventricular cardiomyocytes produced inhibitory currents at less than one-thousandth of the light intensity required by previously available optogenetic tools, such as the proton pump archaerhodopsin-3 (Arch). Because of their greater photocurrents, ACRs permitted complete inhibition of cardiomyocyte electrical activity under conditions in which Arch was inefficient. Most importantly, ACR expression allowed precisely controlled shortening of the action potential duration by switching on the light during its repolarization phase, which was not possible with previously used optogenetic tools. Optical shortening of cardiac action potentials may benefit pathophysiology research and the development of optogenetic treatments for cardiac disorders such as the long QT syndrome. PMID:27628215

  15. Short review of sodium removal experience in PNC

    International Nuclear Information System (INIS)

    Since the establishment of the Power Reactor and Nuclear Fuel Development Corporation (PNC), various research work and development have been carried out for the development of sodium cooled fast breeder reactors. Most of the works, especially those related to large scale facilities are done at the O-arai Engineering Center (OEC) of the PNC. 'Sodium Removal' from components or assemblies has been an area with much concern from the beginning of these works. Among the conventional methods, removal by steam, water, alcohol and vacuumization at high temperatures have been done. In 'Joyo', the experimental fast breeder reactor which reached initial criticality in April 1977, sodium removal from the grapples of the fuel handling facility and the fuel assemblies which come out of the reactor are done as routine work during refueling. Furthermore, when maintenance works for components, such as mechanical sodium pumps for the core cooling system, are done, sodium removal will be done in an exclusive maintenance building

  16. Autologous Transfusion in Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    Radmehr H

    2003-11-01

    Full Text Available Preoperative autologous blood donation is commonly used to reduce exposure to homologous blood transfusions among patients undergoing elective cardiac surgery. The aim of this study was to evaluate the effect of autologous transfusion on patients' hematocryte value, intra and postoperative blood loss, hospitalization time, the development of infective complications and other factors. Materials and Methods: Between June 2001 to April 2002, 208 patients were underwent cardiac surgery in cardiac surgery ward in Imam Khomeini Medical Center. One or more blood units donate from 104 Patients before cardiopulmonary bypass and heparin injection, and transfused to them after CPB and Protamin injection (autologous Group, group 1. 104 patients underwent cardiac surgery routinely (control group, group 2."nResults: Mean of age was 55.9±8.6 in group 1 and 56.6±9.3 in group 2 (P=NS. 73 male and 31 females were in group 1 and 79 males and 25 females were in group 2 (P=NS. Smoking, familial history, hyperlipidemia, diabetes mellitus, renal failure, hypertension, stroke, and history of myocardial infarction was similar in two groups."nSeverity of angina, urgency operation, number vessels disease, duration of cardiopulmonary bypass, duration of aortic cross clamp time, use of internal thoracic artery graft, and number of grafts was similar in both groups. Mean of bleeding post operation was 548 cc in group 1 and 803 cc in-group 2 (P=0.003. Bleeding that need to operation was 1.8% in group 1 and 8.6% in group 2 (P=0.002. Wound infection, mediastinitis, renal failure, ventilatory prolonged, stroke, need to Intra-aortic Balloon Pump (IABP, intraoperative bleeding, and hospital stay was similar in both groups. Mean of extubationt time was 10.2 hours in group 1 and 14.8 hours in group 2 (P=0.001."nConclusion: Preoperative and intra-operative donations are safe and continue to contribute uniquely to blood conservation, providing important options in comprehensive

  17. Factors influencing the cardiac MIBG accumulation

    Energy Technology Data Exchange (ETDEWEB)

    Takatsu, Hisato; Fujiwara, Hisayoshi [Gifu Univ. (Japan). School of Medicine

    1997-02-01

    Following factors possibly influencing the cardiac MIBG accumulation were examined mainly in mice. 1. The specific activity of the MIBG (meta-iodo-benzyl guanidine) on the neuronal and non-neuronal fractions. 2. Motor restriction stress on MIBG accumulation and washout. 3. Loading and restriction of sodium chloride on the accumulation and effect of suppression of renin-angiotensin system. 4. Examinations in Dahl rats. 125I- or 131I-MIBG was intravenously administered to mice at 74 kBq. At 30 min or 4 hr after administration, mice were sacrificed and their left ventricles were dissected out for measurement of radioactivity in a liquid scintillation counter. Salt-sensitive and -resistant Dahl rats were given with 37 MBq of 123I-MIBG and cardiac radioactivity was measured externally for calculation of washout. Factors examined were found highly correlated with the accumulation of MIBG and measurement of its washout was considered useful for evaluating sympathetic activity. (K.H.)

  18. Site specific health and safety plan, 100-HR-3 pump and treat. Revision 1

    International Nuclear Information System (INIS)

    The 100-HR-3 Operable Unit encompasses groundwater contamination underlying the 100-D and 100-H Areas. The primary contaminate is chromium VI. The sources of chromium contamination resulted from the use of sodium dichromate during past reactor operations. The purpose of the 100-HR-3 Pump-and-Treat system is to pump contaminated groundwater through aboveground ion exchange resin and then return the treated waster to the aquifer. This plan covers operation, maintenance, repairs, and pump removal/installation

  19. Firewall function of the endothelial glycocalyx in the regulation of sodium homeostasis.

    Science.gov (United States)

    Korte, Stefanie; Wiesinger, Anne; Straeter, Alexandra S; Peters, Wladimir; Oberleithner, Hans; Kusche-Vihrog, Kristina

    2012-02-01

    Plasma sodium, slightly above normal and in presence of aldosterone, stiffens vascular endothelium and reduces nitric oxide release with the consequence of endothelial dysfunction. This process is mediated by epithelial sodium channels (ENaC) and, most likely, the endothelial Na(+)/K(+)-ATPase. Both, ENaC and Na(+)/K(+)-ATPase, are located in the plasma membrane of endothelial cells and embedded in the endothelial glycocalyx (eGC). This negatively charged biopolymer is directly exposed to the blood stream and selectively buffers sodium ions. We hypothesize that the glycocalyx could interfere with endothelial sodium transport when extracellular sodium varies in the physiological range. Therefore, we modeled the endothelial cell as a pump-leak system measuring changes of intracellular sodium in cultured human endothelial cells. Experiments were performed under low/high extracellular sodium conditions before and after enzymatic eGC removal, and with inhibition of Na(+)/K(+)-ATPase and ENaC, respectively. Three major observations were made: (1) eGC removal by heparinase treatment facilitates sodium to enter/exit the endothelial cells. (2) The direction of net sodium movement across the endothelial plasma membrane depends on the concentration of extracellular sodium which regulates both the Na(+)/K(+)-ATPase and ENaC activity. (3) Removal of eGC and inhibition of sodium transport modify the electrical resistance of endothelial cells. We conclude that the eGC serves as a potential "firewall" preventing uncontrolled access of sodium to the pump-leak system of the endothelial cell. After eGC removal, sodium access to the system is facilitated. Thus the pump-leak system could be regulated by ambient sodium and control vascular permeability in pathophysiological conditions. PMID:22057584

  20. 急性心肌梗死并心源性休克患者早期主动脉内球囊反搏联合急诊介入的疗效观察%Effect of early intra-aortic balloon pumping support combined emergency intervention in patients of acute myocardial infarction complicated with cardiac Shock

    Institute of Scientific and Technical Information of China (English)

    裘毅钢; 李田昌; 陈宇; 李贤峰; 曹毅; 田海涛; 李东韬

    2014-01-01

    目的:探讨早期主动脉内球囊反搏(IABP)植入在急性心肌梗死(AMI)合并心源性休克(CS)患者救治中的价值。方法140例主动脉内球囊反搏联合急诊经皮管状动脉介入治疗(PCI)治疗的AMI合并CS患者,按照发生CS至IABP入的时间,分为:A组为CS至IABP辅助治疗时间<3 h,B组为>3 h;观察指标为靶血管、冠脉病变情况等,并记录总IABP辅助时间,死亡、急性呼吸衰竭、急性肾功能衰竭等临床事件。结果两组间基线情况、靶血管病变、静脉用药等无统计学差异;A组三支病变比率、无复流发生率低于B组,但无统计学差异;A组总IABP辅助时间、全因病死率低于B组,有统计学差异,P<0.05;A组心源性死亡、急性呼吸发生率、急性肾衰发生率均低于B组,但无统计学差异。结论在AMI合并CS的患者尽早应用IABP联合血运重建可能有助于改善生存率。%Objective To investigate the effect of early Intra-aortic balloon pumping (IABP) support combined emergency intervention in patients of acute myocardial infarction (AMI) complicated with cardiac Shock (CS). Methods Clinical data of AMI complicated with cardiac shock in 140 cases of IABP combine with emergency percutaneous coronary intervention (PCI) admitted in Navy General Hospital of the PLA in between January 2011 and December 2012 were collected and divided into two groups according to the time from CS to IABP. The time interval in group A (n=61) was less than 3 hours and group B (n=79) were more than 3 hours. The target coronary artery, the number of culprit vessel, the total time of IABP treatment, hospital mortality, acute respiratory failure, acute renal failure were observed. Results No statistical significance in the rates of triple vessel disease, no-reflow, cardiogenic death, acute respiratory failure and acute renal failure was found between the two groups even although they all reflected lower in

  1. [Sodium bicarbonate infusion for intoxication with tricyclic antidepressives: recommended inspite of lack of scientific evidence].

    Science.gov (United States)

    Vrijlandt, P J; Bosch, T M; Zijlstra, J G; Tulleken, J E; Ligtenberg, J J; van der Werf, T S

    2001-09-01

    Sodium bicarbonate infusion is widely recommended in textbooks for patients who present with self-poisoning from tricyclic antidepressives. Cardiac conduction disorders could also be treated or prevented by means of such an infusion. The scientific basis for these recommendations was investigated by using Medline to search for publications about clinical studies that supported the use of sodium carbonate; 111 articles were scrutinized. Observational studies and case reports mention a rapid improvement in hypotension and cardiac arrhythmias following the administration of sodium bicarbonate. Results from animal experiments are contentious; it is not clear whether alkalinisation or the administration of extra sodium causes the effect. Randomized studies in patients have not been carried out. As the toxicity of sodium bicarbonate is low, and its potential benefit appears to be high, we recommend its use, despite the lack of scientific evidence. No recommendations concerning dosing, concentration and the length of the therapy can be provided on the basis of the literature. PMID:11561485

  2. Off-Pump Coronary Bypass Grafting Causing Stunned Myocardium

    Directory of Open Access Journals (Sweden)

    Feridoun Sabzi

    2015-10-01

    Full Text Available The term “stunned myocardium” refers to abnormalities in the myocardial function following reperfusion and is common in on-pump coronary artery bypass grafting (CABG and is exceedingly rare in off- pump CABG. A 53-year-old man presented with unstable angina due to the severe stenosis of the left anterior descending coronary artery (LAD and the obtuse marginal. Laboratory findings and Chest X-ray revealed nothing abnormal. The intraoperative course was uneventful. The patient left the operating room without any inotropic support. Six hours later, however, he developed low cardiac output .At exploration, cardiac tamponade was excluded and flowmetry showed that the graft had adequate function. Cardiac enzymes were normal. High-dose adrenalin and Dobutamine were administrated and an intra-aortic balloon pump was used. After hemodynamic stabilization, the patient left the Intensive Care Unit without an intra-aortic balloon pump and inotropic support. On the fifth postoperative day, coronary angiography showed patent grafts and correct anastomotic sites. On the seventh postoperative day, the akinetic lateral wall of the left ventricle changed to dyskinesia. Finally after hospital discharge on the thirtieth postoperative day, an echocardiogram showed normal left ventricular function without regional wall motion abnormalities

  3. Mathematical cardiac electrophysiology

    CERN Document Server

    Colli Franzone, Piero; Scacchi, Simone

    2014-01-01

    This book covers the main mathematical and numerical models in computational electrocardiology, ranging from microscopic membrane models of cardiac ionic channels to macroscopic bidomain, monodomain, eikonal models and cardiac source representations. These advanced multiscale and nonlinear models describe the cardiac bioelectrical activity from the cell level to the body surface and are employed in both the direct and inverse problems of electrocardiology. The book also covers advanced numerical techniques needed to efficiently carry out large-scale cardiac simulations, including time and space discretizations, decoupling and operator splitting techniques, parallel finite element solvers. These techniques are employed in 3D cardiac simulations illustrating the excitation mechanisms, the anisotropic effects on excitation and repolarization wavefronts, the morphology of electrograms in normal and pathological tissue and some reentry phenomena. The overall aim of the book is to present rigorously the mathematica...

  4. Biomaterials for cardiac regeneration

    CERN Document Server

    Ruel, Marc

    2015-01-01

    This book offers readers a comprehensive biomaterials-based approach to achieving clinically successful, functionally integrated vasculogenesis and myogenesis in the heart. Coverage is multidisciplinary, including the role of extracellular matrices in cardiac development, whole-heart tissue engineering, imaging the mechanisms and effects of biomaterial-based cardiac regeneration, and autologous bioengineered heart valves. Bringing current knowledge together into a single volume, this book provides a compendium to students and new researchers in the field and constitutes a platform to allow for future developments and collaborative approaches in biomaterials-based regenerative medicine, even beyond cardiac applications. This book also: Provides a valuable overview of the engineering of biomaterials for cardiac regeneration, including coverage of combined biomaterials and stem cells, as well as extracellular matrices Presents readers with multidisciplinary coverage of biomaterials for cardiac repair, including ...

  5. Dialysate sodium and sodium gradient in maintenance hemodialysis: a neglected sodium restriction approach?

    OpenAIRE

    Munoz Mendoza, Jair; Sun, Sumi; Chertow, Glenn M.; Moran, John, (Thesis); Doss, Sheila; Schiller, Brigitte

    2011-01-01

    Background. A higher sodium gradient (dialysate sodium minus pre-dialysis plasma sodium) during hemodialysis (HD) has been associated with sodium loading; however, its role is not well studied. We hypothesized that a sodium dialysate prescription resulting in a higher sodium gradient is associated with increases in interdialytic weight gain (IDWG), blood pressure (BP) and thirst.

  6. Mercury Toxicity on Sodium Pump and Organoseleniums Intervention: A Paradox

    Directory of Open Access Journals (Sweden)

    Ige Joseph Kade

    2012-01-01

    Full Text Available Mercury is an environmental poison, and the damage to living system is generally severe. The severity of mercury poisoning is consequent from the fact that it targets the thiol-containing enzymes, irreversibly oxidizing their critical thiol groups, consequently leading to an inactivation of the enzyme. The Na+/K+-ATPase is a sulfhydryl protein that is sensitive to Hg2+ assault. On the other hand, organoseleniums are a class of pharmacologically promising compounds with potent antioxidant effects. While Hg2+ oxidizes sulfhydryl groups of Na+/K+-ATPase under in vitro and in vivo conditions, the organoselenium compounds inhibit Na+/K+-ATPase in vitro but enhance its activities under in vivo conditions with concomitant increase in the level of endogenous thiols. Paradoxically, it appears that these two thiol oxidants can be used to counteract one another under in vivo conditions, and this hypothesis serves as the basis for this paper.

  7. [Minimally invasive direct cardiac surgery with the jakoscope retractor].

    Science.gov (United States)

    Galajda, Zoltán; Jakó, Géza; von Jakó, Ronald; Péterffy, Arpád

    2008-01-20

    The authors present a surgical retractor named jakoscope, useful in the field of abdominal, urological, vascular, thoracic and cardiac surgery procedures. This multifunctional device offers the possibility to utilize Minimally Invasive Direct Access Surgical Technology (MIDAST) in the above mentioned surgical specialties. In their department the authors use the jakoscope retractor for aortic valve replacement, off-pump coronary bypass operations and radiofrequency pulmonary vein ablation by mini-thoracotomy approach. In this report they published for the first time their experience with jakoscope device in the field of cardiac surgery. In these operations the device assured adequate minimally invasive direct access, without complications.

  8. Pump application and maintenance

    International Nuclear Information System (INIS)

    Nuclear maintenance programs are typically organized by overall application, function, cost impact, and failure histories. Each maintenance program is uniquely tailored for each plant's specific goals and objectives. Most maintenance programs include pump maintenance within an application and/or a function. NMAC provides guidance on maintenance, troubleshooting, and applications of Deep Draft Vertical Centrifugal Pumps, Main Coolant Pump Seals, Feedwater Pumps, and Charging Pumps. Each maintenance guide includes a technical discussion of the design and operating issues which influence pump and component performance, reliability, and availability. The guides also discuss comprehensive inspection and corresponding repair Advisory groups consisting of utility, manufacturer, and regulatory representatives oversee the development of the NMAC guides, and review by utility personnel further augments the development process

  9. Electrokinetic pumps and actuators

    International Nuclear Information System (INIS)

    Flow and ionic transport in porous media are central to electrokinetic pumping as well as to a host of other microfluidic devices. Electrokinetic pumping provides the ability to create high pressures (to over 10,000 psi) and high flow rates (over 1 mL/min) with a device having no moving parts and all liquid seals. The electrokinetic pump (EKP) is ideally suited for applications ranging from a high pressure integrated pump for chip-scale HPLC to a high flow rate integrated pump for forced liquid convection cooling of high-power electronics. Relations for flow rate and current fluxes in porous media are derived that provide a basis for analysis of complex microfluidic systems as well as for optimization of electrokinetic pumps

  10. [Cardiac evaluation before non-cardiac surgery].

    Science.gov (United States)

    Menzenbach, Jan; Boehm, Olaf

    2016-07-01

    Before non-cardiac surgery, evaluation of cardiac function is no frequent part of surgical treatment. European societies of anesthesiology and cardiology published consensus-guidelines in 2014 to present a reasonable approach for preoperative evaluation. This paper intends to differentiate the composite of perioperative risk and to display the guidelines methodical approach to handle it. Features to identify patients at risk from an ageing population with comorbidities, are the classification of surgical risk, functional capacity and risk indices. Application of diagnostic means, should be used adjusted to this risk estimation. Cardiac biomarkers are useful to discover risk of complications or mortality, that cannot be assessed by clinical signs. After preoperative optimization and perioperative cardiac protection, the observation of the postoperative period remains, to prohibit complications or even death. In consideration of limited resources of intensive care department, postoperative ward rounds beyond intensive care units are considered to be an appropriate instrument to avoid or recognize complications early to reduce postoperative mortality. PMID:27479258

  11. The Insulin Pump

    OpenAIRE

    Toews, C. J.

    1985-01-01

    Subcutaneous continuous insulin infusion systems deliver insulin at a basal rate designed to keep blood glucose levels normal in the non-fed state. Additional insulin is delivered at meal time. Pumps can provide near optimal control of blood glucose concentrations in selected, highly motivated patients. The pump provides better diabetic control than once daily insulin injections, although several daily injections can provide comparable control. Optimal control with the pump causes some short-...

  12. Fakir fuel pump

    Science.gov (United States)

    1922-01-01

    In designing the Fakir fuel pump, the fundamental idea was to obtain a simple and reliable method of conveying the fuel from a low tank to the carburetor, with the avoidance of the faults of all former methods and the simultaneous warming of the fuel by means of the heat of compression generated. The principle of the Fakir fuel pump rests on the well-known principle of the diaphragm pump, which must be suitably adapted to the present purpose.

  13. Detection of pump degradation

    Energy Technology Data Exchange (ETDEWEB)

    Greene, R.H.; Casada, D.A.; Ayers, C.W. [and others

    1995-08-01

    This Phase II Nuclear Plant Aging Research study examines the methods of detecting pump degradation that are currently employed in domestic and overseas nuclear facilities. This report evaluates the criteria mandated by required pump testing at U.S. nuclear power plants and compares them to those features characteristic of state-of-the-art diagnostic programs and practices currently implemented by other major industries. Since the working condition of the pump driver is crucial to pump operability, a brief review of new applications of motor diagnostics is provided that highlights recent developments in this technology. The routine collection and analysis of spectral data is superior to all other technologies in its ability to accurately detect numerous types and causes of pump degradation. Existing ASME Code testing criteria do not require the evaluation of pump vibration spectra but instead overall vibration amplitude. The mechanical information discernible from vibration amplitude analysis is limited, and several cases of pump failure were not detected in their early stages by vibration monitoring. Since spectral analysis can provide a wealth of pertinent information concerning the mechanical condition of rotating machinery, its incorporation into ASME testing criteria could merit a relaxation in the monthly-to-quarterly testing schedules that seek to verify and assure pump operability. Pump drivers are not included in the current battery of testing. Operational problems thought to be caused by pump degradation were found to be the result of motor degradation. Recent advances in nonintrusive monitoring techniques have made motor diagnostics a viable technology for assessing motor operability. Motor current/power analysis can detect rotor bar degradation and ascertain ranges of hydraulically unstable operation for a particular pump and motor set. The concept of using motor current or power fluctuations as an indicator of pump hydraulic load stability is presented.

  14. Solubilities of sodium nitrate, sodium nitrite, and sodium aluminate in simulated nuclear waste

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, D.A.; Herting, D.L.

    1984-09-01

    Solubilities were determined for sodium nitrate, sodium nitrite, and sodium aluminate in synthetic nuclear waste liquor. Solubilities were determined as a function of temperature and solution composition (concentrations of sodium hydroxide, sodium nitrate, sodium nitrite, and sodium aluminate). Temperature had the greatest effect on the solubilities of sodium nitrate and sodium nitrite and a somewhat lesser effect on sodium aluminate solubility. Hydroxide had a great effect on the solubilities of all three salts. Other solution components had minor effects. 2 references, 8 figures, 11 tables.

  15. Solubilities of sodium nitrate, sodium nitrite, and sodium aluminate in simulated nuclear waste

    International Nuclear Information System (INIS)

    Solubilities were determined for sodium nitrate, sodium nitrite, and sodium aluminate in synthetic nuclear waste liquor. Solubilities were determined as a function of temperature and solution composition (concentrations of sodium hydroxide, sodium nitrate, sodium nitrite, and sodium aluminate). Temperature had the greatest effect on the solubilities of sodium nitrate and sodium nitrite and a somewhat lesser effect on sodium aluminate solubility. Hydroxide had a great effect on the solubilities of all three salts. Other solution components had minor effects. 2 references, 8 figures, 11 tables

  16. Cardiac surgery in a fixed-reimbursement environment.

    Science.gov (United States)

    Scully, H E

    1996-02-01

    Hospital and physician services in Canada are funded by public (government) sources. This article will describe the practice of cardiac surgery in this setting. Federal legislation has prescribed the principles of accessibility, universality, comprehensiveness, portability, and public administration for essential healthcare services in Canada. Provincial and territorial governments are responsible for the provision of services, receiving federal tax and cash transfers that supplement provincial/territorial funds for hospital, physician, and community health services. Hospitals negotiate annually for global budgets. Physicians work as independent contractors in hospitals (and communities) and are usually paid as specified by fee-for-service contracts negotiated at intervals with governments. Cardiac surgical services have been planned conjointly with government. Forty-two centers in Canada serve a population of 28 million. All but three of these centers are located in tertiary teaching hospitals; all but one do more than 200 pumps annually. The rate of cardiac operations is 80 per 100,000 population. In Ontario, the Provincial Adult Cardiac Care Network makes recommendations to governments about the distribution of the 7,600 pumps annually (population, 11 million), rationalizing waiting lists based on an urgency rating scale. Patients requiring emergent/urgent operations are well served. The average waiting time for an elective cardiac operation is 10.5 weeks. The waiting list mortality is less than 0.5%. The Provincial Adult Cardiac Care Network also determines the placement of new programs and participates in creating hospital funding formulas developed from a combination of resource and acuity intensity weighting. Most surgeons hold full-time academic appointments but are funded largely by practice income. Surgical fees average $2,000 (Canada) per case. Overhead, including malpractice insurance, is approximately 45%. All Canadian patients enjoy reasonably timely

  17. Champagne Heat Pump

    Science.gov (United States)

    Jones, Jack A.

    2004-01-01

    The term champagne heat pump denotes a developmental heat pump that exploits a cycle of absorption and desorption of carbon dioxide in an alcohol or other organic liquid. Whereas most heat pumps in common use in the United States are energized by mechanical compression, the champagne heat pump is energized by heating. The concept of heat pumps based on other absorption cycles energized by heat has been understood for years, but some of these heat pumps are outlawed in many areas because of the potential hazards posed by leakage of working fluids. For example, in the case of the water/ammonia cycle, there are potential hazards of toxicity and flammability. The organic-liquid/carbon dioxide absorption/desorption cycle of the champagne heat pump is similar to the water/ammonia cycle, but carbon dioxide is nontoxic and environmentally benign, and one can choose an alcohol or other organic liquid that is also relatively nontoxic and environmentally benign. Two candidate nonalcohol organic liquids are isobutyl acetate and amyl acetate. Although alcohols and many other organic liquids are flammable, they present little or no flammability hazard in the champagne heat pump because only the nonflammable carbon dioxide component of the refrigerant mixture is circulated to the evaporator and condenser heat exchangers, which are the only components of the heat pump in direct contact with air in habitable spaces.

  18. Detection of pump degradation

    Energy Technology Data Exchange (ETDEWEB)

    Casada, D. [Oak Ridge National Lab., TN (United States)

    1995-04-01

    There are a variety of stressors that can affect the operation of centrifugal pumps. Although these general stressors are active in essentially all centrifugal pumps, the stressor level and the extent of wear and degradation can vary greatly. Parameters that affect the extent of stressor activity are manifold. In order to assure the long-term operational readiness of a pump, it is important to both understand the nature and magnitude of the specific degradation mechanisms and to monitor the performance of the pump. The most commonly applied method of monitoring the condition of not only pumps, but rotating machinery in general, is vibration analysis. Periodic or continuous special vibration analysis is a cornerstone of most pump monitoring programs. In the nuclear industry, non-spectral vibration monitoring of safety-related pumps is performed in accordance with the ASME code. Pump head and flow rate are also monitored, per code requirements. Although vibration analysis has dominated the condition monitoring field for many years, there are other measures that have been historically used to help understand pump condition; advances in historically applied technologies and developing technologies offer improved monitoring capabilities. The capabilities of several technologies (including vibration analysis, dynamic pressure analysis, and motor power analysis) to detect the presence and magnitude of both stressors and resultant degradation are discussed.

  19. Optically pumped atoms

    CERN Document Server

    Happer, William; Walker, Thad

    2010-01-01

    Covering the most important knowledge on optical pumping of atoms, this ready reference is backed by numerous examples of modelling computation for optical pumped systems. The authors show for the first time that modern scientific computing software makes it practical to analyze the full, multilevel system of optically pumped atoms. To make the discussion less abstract, the authors have illustrated key points with sections of MATLAB codes. To make most effective use of contemporary mathematical software, it is especially useful to analyze optical pumping situations in the Liouville spa

  20. Sick sinus syndrome, progressive cardiac conduction disease, atrial flutter and ventricular tachycardia caused by a novel SCN5A mutation

    DEFF Research Database (Denmark)

    Holst, Anders G; Liang, Bo; Jespersen, Thomas;

    2010-01-01

    Mutations in the cardiac sodium channel encoded by the gene SCN5A can result in a wide array of phenotypes. We report a case of a young male with a novel SCN5A mutation (R121W) afflicted by sick sinus syndrome, progressive cardiac conduction disorder, atrial flutter and ventricular tachycardia. His...... father carried the same mutation, but had a milder phenotype, presenting with progressive cardiac conduction later in life. The mutation was found to result in a loss-of-function in the sodium current. In conclusion, the same SCN5A mutation can result in a wide array of clinical phenotypes and perhaps...

  1. Thermophysical properties of sodium

    International Nuclear Information System (INIS)

    Thermophysical properties of sodium for reactor safety studies are presented. Subcooled, superheated and saturated properties are given. A summary of the thermophysical properties is given in tabular form

  2. Cardiac metabolism and arrhythmias

    OpenAIRE

    Barth, Andreas S.; Tomaselli, Gordon F.

    2009-01-01

    Sudden cardiac death remains a leading cause of mortality in the Western world, accounting for up to 20% of all deaths in the U.S.1, 2 The major causes of sudden cardiac death in adults age 35 and older are coronary artery disease (70–80%) and dilated cardiomyopathy (10–15%).3 At the molecular level, a wide variety of mechanisms contribute to arrhythmias that cause sudden cardiac death, ranging from genetic predisposition (rare mutations and common polymorphisms in ion channels and structural...

  3. Comprehensive cardiac rehabilitation

    DEFF Research Database (Denmark)

    Kruse, Marie; Hochstrasser, Stefan; Zwisler, Ann-Dorthe O;

    2006-01-01

    OBJECTIVES: The costs of comprehensive cardiac rehabilitation are established and compared to the corresponding costs of usual care. The effect on health-related quality of life is analyzed. METHODS: An unprecedented and very detailed cost assessment was carried out, as no guidelines existed...... and may be as high as euro 1.877. CONCLUSIONS: Comprehensive cardiac rehabilitation is more costly than usual care, and the higher costs are not outweighed by a quality of life gain. Comprehensive cardiac rehabilitation is, therefore, not cost-effective....

  4. Liquid pump for astronaut cooling

    Science.gov (United States)

    Carson, M. A.

    1972-01-01

    The Apollo portable life support system water-recirculation pump used for astronaut cooling is described. The problems associated with an early centrifugal pump and how these problems were overcome by the use of a new diaphragm pump are discussed. Performance comparisons of the two pump designs are given. Developmental problems and flight results with the diaphragm pump are discussed.

  5. The Analysis of an End Effect according to the Input Frequency Change in the EM Pump

    International Nuclear Information System (INIS)

    In general, an electromagnetic (EM) pump is considered to circulate a liquid sodium coolant for a Sodium Fast Reactor (SFR). The EM pump has an end effect at both ends basically due to its finite core length. The generated magnetic field across the flow gap is distorted at both ends of the pump. Consequently, there arises reduction on the developed force by the vector product of that magnetic field and its perpendicular induced current. Especially, it experiences even the opposite pumping force near the pump inlet. That causes low efficiency of the pump and resultantly brings about bad performance of a pump. The present study theoretically shows that this end effect can be lessened by control of input frequency. It is predicted that pump operates much more efficiently in the range of low frequency around teen hertz than in that of high frequency over 60 Hz. The force density is investigated in the narrow annular channel of the pump with the length of 84cm according to pump axial coordinates at various frequency

  6. Pump element for a tube pump

    DEFF Research Database (Denmark)

    2011-01-01

    relative to the rod element so as to allow for a fluid flow in the tube through the first valve member, along the rod element, and through the second valve member. The tube comprises an at least partly flexible tube portion between the valve members such that a repeated deformation of the flexible tube...... pump as mentioned above, thereby acting to generate a fluid flow through the tube upon repeated deformation of the tube between the two valve members. The pump element may comprise a connecting part for coupling to another tube and may comprise a sealing part establishing a fluid tight connection...

  7. Cardiac Risk Assessment

    Science.gov (United States)

    ... to assess cardiac risk include: High-sensitivity C-reactive protein (hs-CRP) : Studies have shown that measuring ... LDL-C but does not respond to typical strategies to lower LDL-C such as diet, exercise, ...

  8. Sudden Cardiac Arrest

    Science.gov (United States)

    ... Heart Risk Factors & Prevention Heart Diseases & Disorders Atrial Fibrillation (AFib) Sudden Cardiac Arrest (SCA) SCA: Who's At Risk? Prevention of SCA What Causes SCA? SCA Awareness Atrial Flutter Heart Block Heart Failure Sick Sinus Syndrome Substances & Heart Rhythm Disorders Symptoms & ...

  9. Socially differentiated cardiac rehabilitation

    DEFF Research Database (Denmark)

    Meillier, Lucette Kirsten; Nielsen, Kirsten Melgaard; Larsen, Finn Breinholt;

    2012-01-01

    to a standard rehabilitation programme (SRP). If patients were identified as socially vulnerable, they were offered an extended version of the rehabilitation programme (ERP). Excluded patients were offered home visits by a cardiac nurse. Concordance principles were used in the individualised programme elements......%. Patients were equally distributed to the SRP and the ERP. No inequality was found in attendance and adherence among referred patients. Conclusions: It seems possible to overcome unequal referral, attendance, and adherence in cardiac rehabilitation by organisation of systematic screening and social......Aim: The comprehensive cardiac rehabilitation (CR) programme after myocardial infarction (MI) improves quality of life and results in reduced cardiac mortality and recurrence of MI. Hospitals worldwide face problems with low participation rates in rehabilitation programmes. Inequality...

  10. Cardiac arrest - cardiopulmonary resuscitation

    Institute of Scientific and Technical Information of China (English)

    Basri Lenjani; Besnik Elshani; Nehat Baftiu; Kelmend Pallaska; Kadir Hyseni; Njazi Gashi; Nexhbedin Karemani; Ilaz Bunjaku; Taxhidin Zaimi; Arianit Jakupi

    2014-01-01

    Objective:To investigate application of cardiopulmonary resuscitation(CPR) measures within the golden minutes inEurope.Methods:The material was taken from theUniversityClinical Center ofKosovo -EmergencyCentre inPristina, during the two(2) year period(2010-2011).The collected date belong to the patients with cardiac arrest have been recorded in the patients' log book protocol at the emergency clinic.Results:During the2010 to2011 in the emergency center of theCUCK inPristina have been treated a total of269 patients with cardiac arrest, of whom159 or59.1% have been treated in2010, and110 patients or40.9% in2011.Of the269 patients treated in the emergency centre,93 or34.6% have exited lethally in the emergency centre, and176 or 65.4% have been transferred to other clinics.In the total number of patients with cardiac arrest, males have dominated with186 cases, or69.1%.The average age of patients included in the survey was56.7 year oldSD±16.0 years.Of the269 patients with cardiac arrest, defibrillation has been applied for93 or34.6% of patients.In the outpatient settings defibrillation has been applied for3 or3.2% of patients.Patients were defibrillated with application of one to four shocks. Of27 cases with who have survived cardiac arrest, none of them have suffered cardiac arrest at home,3 or11.1% of them have suffered cardiac arrest on the street, and24 or88.9% of them have suffered cardiac arrest in the hospital.5 out of27 patients survived have ended with neurological impairment.Cardiac arrest cases were present during all days of the week, but frequently most reported cases have been onMonday with32.0% of cases, and onFriday with24.5% of cases. Conclusions:All survivors from cardiac arrest have received appropriate medical assistance within10 min from attack, which implies that if cardiac arrest occurs near an institution health care(with an opportunity to provide the emergent health care) the rate of survival is higher.

  11. Neuromuscular blockade in cardiac surgery: An update for clinicians

    Directory of Open Access Journals (Sweden)

    Hemmerling Thomas

    2008-01-01

    Full Text Available There have been great advancements in cardiac surgery over the last two decades; the widespread use of off-pump aortocoronary bypass surgery, minimally invasive cardiac surgery, and robotic surgery have also changed the face of cardiac anaesthesia. The concept of "Fast-track anaesthesia" demands the use of nondepolarising neuromuscular blocking drugs with short duration of action, combining the ability to provide (if necessary sufficiently profound neuromuscular blockade during surgery and immediate re-establishment of normal neuromuscular transmission at the end of surgery. Postoperative residual muscle paralysis is one of the major hurdles for immediate or early extubation after cardiac surgery. Nondepolarising neuromuscular blocking drugs for cardiac surgery should therefore be easy to titrate, of rapid onset and short duration of action with a pathway of elimination independent from hepatic or renal dysfunction, and should equally not affect haemodynamic stability. The difference between repetitive bolus application and continuous infusion is outlined in this review, with the pharmacodynamic and pharmacokinetic characteristics of vecuronium, pancuronium, rocuronium, and cisatracurium. Kinemyography and acceleromyography are the most important currently used neuromuscular monitoring methods. Whereas monitoring at the adductor pollicis muscle is appropriate at the end of surgery, monitoring of the corrugator supercilii muscle better reflects neuromuscular blockade at more central, profound muscles, such as the diaphragm, larynx, or thoraco-abdominal muscles. In conclusion, cisatracurium or rocuronium is recommended for neuromuscular blockade in modern cardiac surgery.

  12. Magnetic heat pump design

    Science.gov (United States)

    Kirol, L. D.; Dacus, M. W.

    1988-03-01

    Heat pumps utilizing the magnetocaloric effect offer a potentially attractive alternative to conventional heat pumps and refrigerators. Many physical configurations of magnetic heat pumps are possible. Major classes include those requiring electrical energy input and those with mechanical energy input. Mechanical energy is used to move magnets, working material, or magnetic shielding. Each type of mechanical magnetic heat pump can be built in a rotary (recuperative) or reciprocal (regenerative) configuration. Machines with electrical energy input utilize modulation of the magnetic field to cause working material to execute the desired thermodynamic cycle, and can also be recuperative or regenerative. Recuperative rotary heat pumps in which working material is moved past stationary magnets is the preferred configuration. Regenerative devices suffer performance degradation from temperature change of regenerator material and mixing and conduction in the regenerator. Field modulated cycles are not practical due to ac losses in superconducting magnets. Development of methods for recuperator fluid pumping is the major challenge in design of rotary recuperative devices. Several pumping options are presented, and the design of a bench scale heat pump described.

  13. Water Treatment Technology - Pumps.

    Science.gov (United States)

    Ross-Harrington, Melinda; Kincaid, G. David

    One of twelve water treatment technology units, this student manual on pumps provides instructional materials for three competencies. (The twelve units are designed for a continuing education training course for public water supply operators.) The competencies focus on the following areas: types of pumps in plant and distribution systems, pump…

  14. Incidence and management of diaphragmatic palsy in patients after cardiac surgery

    OpenAIRE

    Mehta Yatin; Vats Mayank; Singh Ajmer; Trehan Naresh

    2008-01-01

    Background: Diaphragm is the most important part of the respiratory system. Diaphragmatic palsy following cardiac surgery is not uncommon and can cause deterioration of pulmonary functions and attendant pulmonary complications. Objectives: Aim of this study was to observe the incidence of diaphragmatic palsy after off pump coronary artery bypass grafting (OPCAB) as compared to conventional CABG and to assess the efficacy of chest physiotherapy on diaphragmatic palsy in post cardiac surgica...

  15. THE INVESTIGATION OF THE INTERACTION OF THE IMPLANTABLE ROTARY BLOOD PUMP AND THE LEFT VENTRICLE ON THE MOCK CIRCULATION SYSTEM

    Directory of Open Access Journals (Sweden)

    E. G. Konysheva

    2010-01-01

    Full Text Available We analyzed the dynamics of the interaction of rotary pump, connected to the scheme «the left ventricle – aor- ta», and left ventricle in norms and heart failure, using data obtained on the mock circulatory system. Adverse pumping states such as suction and regurgitation can be detected. These limits depend on the degree of cardiac failure, which confirms the need to control the speed of rotation of the impeller in the range of the cardiac failure from pathology to normal. It has been shown that the pulsating pressure at the inlet of the pump modulates the flow of the pump, making it a pulsating, what positively affects on the dynamics of cardiac output. 

  16. Awareness in cardiac anesthesia.

    LENUS (Irish Health Repository)

    Serfontein, Leon

    2010-02-01

    Cardiac surgery represents a sub-group of patients at significantly increased risk of intraoperative awareness. Relatively few recent publications have targeted the topic of awareness in this group. The aim of this review is to identify areas of awareness research that may equally be extrapolated to cardiac anesthesia in the attempt to increase understanding of the nature and significance of this scenario and how to reduce it.

  17. Cardiac rehabilitation in Germany.

    Science.gov (United States)

    Karoff, Marthin; Held, Klaus; Bjarnason-Wehrens, Birna

    2007-02-01

    The purpose of this review is to give an overview of the rehabilitation measures provided for cardiac patients in Germany and to outline its legal basis and outcomes. In Germany the cardiac rehabilitation system is different from rehabilitation measures in other European countries. Cardiac rehabilitation in Germany since 1885 is based on specific laws and the regulations of insurance providers. Cardiac rehabilitation has predominantly been offered as an inpatient service, but has recently been complemented by outpatient services. A general agreement on the different indications for offering these two services has yet to be reached. Cardiac rehabilitation is mainly offered after an acute cardiac event and bypass surgery. It is also indicated in severe heart failure and special cases of percutaneous coronary intervention. Most patients are men (>65%) and the age at which events occur is increasing. The benefits obtained during the 3-4 weeks after an acute event, and confirmed in numerous studies, are often later lost under 'usual care' conditions. Many attempts have been made by rehabilitation institutions to improve this deficit by providing intensive aftercare. One instrument set up to achieve this is the nationwide institution currently comprising more than 6000 heart groups with approximately 120000 outpatients. After coronary artery bypass grafting or acute coronary syndrome cardiac rehabilitation can usually be started within 10 days. The multidisciplinary rehabilitation team consists of cardiologists, psychologists, exercise therapists, social workers, nutritionists and nurses. The positive effects of cardiac rehabilitation are also important economically, for example, for the improvement of secondary prevention and vocational integration. PMID:17301623

  18. Cardiac tumours in infancy

    OpenAIRE

    Yadava, O.P.

    2012-01-01

    Cardiac tumours in infancy are rare and are mostly benign with rhabdomyomas, fibromas and teratomas accounting for the majority. The presentation depends on size and location of the mass as they tend to cause cavity obstruction or arrhythmias. Most rhabdomyomas tend to regress spontaneously but fibromas and teratomas generally require surgical intervention for severe haemodynamic or arrhythmic complications. Other relatively rare cardiac tumours too are discussed along with an Indian perspect...

  19. Infected cardiac hydatid cyst

    OpenAIRE

    Ceviz, M; Becit, N; Kocak, H.

    2001-01-01

    A 24 year old woman presented with chest pain and palpitation. The presence of a semisolid mass—an echinococcal cyst or tumour—in the left ventricular apex was diagnosed by echocardiography, computed tomography, and magnetic resonance imaging. The infected cyst was seen at surgery. The cyst was removed successfully by using cardiopulmonary bypass with cross clamp.


Keywords: cardiac hydatid cyst; infected cardiac hydatid cyst

  20. Stability of colistimethate sodium in a disposable elastomeric infusion device.

    Science.gov (United States)

    Abdulla, Alan; van Leeuwen, Roelof W F; de Vries Schultink, Aurelia H M; Koch, Birgit C P

    2015-01-01

    Infections of the respiratory tract with Pseudomonas aeruginosa in cystic fibrosis patients are frequently treated with colistimethate sodium (CMS). For the intravenous administration of CMS a disposable elastomeric pump is a convenient option. To date, there are no data available on the chemical stability of CMS solutions stored in elastomeric pumps. We evaluated the chemical stability of 0.8 mg/mL solutions of CMS by measuring the degradation over a period of 7 days. Test samples were prepared by diluting CMS with saline solution (0.9%). The preparations were transferred to 100-mL elastomeric pumps and stored at 4 °C. The chemical stability was measured by a high-performance liquid chromatography method with UV detection. There was no degradation of CMS (elastomeric pump. PMID:25863116

  1. Normetex Pump Alternatives Study

    Energy Technology Data Exchange (ETDEWEB)

    Clark, Elliot A.

    2013-04-25

    A mainstay pump for tritium systems, the Normetex scroll pump, is currently unavailable because the Normetex company went out of business. This pump was an all-metal scroll pump that served tritium processing facilities very well. Current tritium system operators are evaluating replacement pumps for the Normetex pump and for general used in tritium service. An all-metal equivalent alternative to the Normetex pump has not yet been identified. 1. The ideal replacement tritium pump would be hermetically sealed and contain no polymer components or oils. Polymers and oils degrade over time when they contact ionizing radiation. 2. Halogenated polymers (containing fluorine, chlorine, or both) and oils are commonly found in pumps. These materials have many properties that surpass those of hydrocarbon-based polymers and oils, including thermal stability (higher operating temperature) and better chemical resistance. Unfortunately, they are less resistant to degradation from ionizing radiation than hydrocarbon-based materials (in general). 3. Polymers and oils can form gaseous, condensable (HF, TF), liquid, and solid species when exposed to ionizing radiation. For example, halogenated polymers form HF and HCl, which are extremely corrosive upon reaction with water. If a pump containing polymers or oils must be used in a tritium system, the system must be designed to be able to process the unwanted by-products. Design features to mitigate degradation products include filters and chemical or physical traps (eg. cold traps, oil traps). 4. Polymer components can work in tritium systems, but must be replaced regularly. Polymer components performance should be monitored or be regularly tested, and regular replacement of components should be viewed as an expected normal event. A radioactive waste stream must be established to dispose of used polymer components and oil with an approved disposal plan developed based on the facility location and its regulators. Polymers have varying

  2. Annular sodium flowsensor

    International Nuclear Information System (INIS)

    This paper describes a unique eddy-current type liquid sodium flowsensor, designed as a joint effort between Argonne National Laboratory and Kaman Instrumentation Corp. Test results are included for operation of the flowsensor mounted on a sodium test loop whose configuration simulates the actual operating conditions, except for the magnetic field of the ALIP

  3. Visibility in sodium fume

    International Nuclear Information System (INIS)

    The appearance of sodium fume of unknown concentration and the effects of short term exposure on unprotected workers is described. The molecular extinction coefficient of sodium fume is calculated from which light transmission data, and a rapid method for the estimation of the fume concentration is proposed. (author)

  4. Cardiac applications of optogenetics.

    Science.gov (United States)

    Ambrosi, Christina M; Klimas, Aleksandra; Yu, Jinzhu; Entcheva, Emilia

    2014-08-01

    In complex multicellular systems, such as the brain or the heart, the ability to selectively perturb and observe the response of individual components at the cellular level and with millisecond resolution in time, is essential for mechanistic understanding of function. Optogenetics uses genetic encoding of light sensitivity (by the expression of microbial opsins) to provide such capabilities for manipulation, recording, and control by light with cell specificity and high spatiotemporal resolution. As an optical approach, it is inherently scalable for remote and parallel interrogation of biological function at the tissue level; with implantable miniaturized devices, the technique is uniquely suitable for in vivo tracking of function, as illustrated by numerous applications in the brain. Its expansion into the cardiac area has been slow. Here, using examples from published research and original data, we focus on optogenetics applications to cardiac electrophysiology, specifically dealing with the ability to manipulate membrane voltage by light with implications for cardiac pacing, cardioversion, cell communication, and arrhythmia research, in general. We discuss gene and cell delivery methods of inscribing light sensitivity in cardiac tissue, functionality of the light-sensitive ion channels within different types of cardiac cells, utility in probing electrical coupling between different cell types, approaches and design solutions to all-optical electrophysiology by the combination of optogenetic sensors and actuators, and specific challenges in moving towards in vivo cardiac optogenetics.

  5. Cardiac arrhythmia and heart failure: From bench to bedside

    Institute of Scientific and Technical Information of China (English)

    Yong-Fu Xiao

    2011-01-01

    @@ Cardiac arrhythmia is an abnormal rate and/or rhythm of a heart due to its abnormal electrical impulse origination and/or propagation.Various etiologies can cause arrhythnuas.Heart failure(HF)is a clinical syndrome due to an impaired heart that can not pump sufficient blood to meet the systemic metabolic needs.The common causes of HF include myocardial infarction,hypertension,valvular heart disease,and cardiomyopathy.

  6. Emergency off-pump coronary artery surgery

    Institute of Scientific and Technical Information of China (English)

    Shahzad G Raja; Zulfiqar Haider; Haider Zaman

    2004-01-01

    Background Off-pump coronary artery bypass grafting is fast-becoming a procedure of choice for elective revascularization in high-risk patients with multi-vessel coronary artery disease. However, the role of off-pump coronary artery bypass grafting for patients with acute coronary syndromes requiring emergency revascularization still requires validation. We present our experience to show the feasibility of off-pump coronary artery surgery as an emergency revascularization technique. Methods From April 2001 to September 2003, emergency (operation within 24 hours after hospitalization) coronary artery bypass grafting without cardiopulmonary bypass (CPB) was performed in 66 patients with a mean age of (66.9±5.4) years (range 49-72 years). They presented acute coronary syndromes with 38 patients on platelet glycoprotein Ⅱb/Ⅲa receptor antagonists. All patients underwent off-pump coronary artery bypass surgery via sternotomy with the intention of complete coronary revascularization.Results An average of 2.9 grafts per patient were performed and the posterior descending artery and marginal branches of the circumflex artery were grafted in 83.3% of the patients. There were 4 events of intraoperative cardiac instability, precipitated by occlusion of right coronary artery or positioning of a cardiomegaly heart, leading to immediate conversion to CPB. The mortality rate was 3% (2/66). Two patients suffered postoperative stroke while three needed hemofiltration for acute renal failure. Post surgery elective coronary angiography (n=46) showed no significant stenosis.Conclusion Emergency off-pump coronary artery surgery with complete revascularization is feasible in patients with acute coronary syndrome with low morbidity and mortality and excellent early results.

  7. Large scale breeder reactor plant prototype mechanical pump conceptual design study

    Energy Technology Data Exchange (ETDEWEB)

    1976-07-01

    This final report is a complete conceptual design study of a mechanical pump for a large scale breeder reactor plant. The pumps are located in the cold leg side of the loops. This makes the net positive suction head available - NPSHA - low, and is, in fact, a major influencing factor in the design. Where possible, experience gained from the Clinch River Project and the FFTF is used in this study. Experience gained in the design, manufacturer, and testing of pumps in general and sodium pumps in particular is reflected in this report. The report includes estimated cost and time schedule for design, manufacture, and testing. It also includes a recommendation for development needs.

  8. Neurocognitive impairment after off-pump and on-pump coronary artery bypass graft surgery – an Iranian experience

    Directory of Open Access Journals (Sweden)

    Mehdi Farhoudi

    2010-11-01

    Full Text Available Mehdi Farhoudi1, Kaveh Mehrvar2, Abbas Afrasiabi3, Rezayat Parvizi3, Ahmad Ali Khalili3, Babak Nasiri3, Khosrow Hashemzadeh3, Kamyar Ghabili41Neurosciences Research Center, Imam Reza Hospital, 2Razi Hospital, 3Cardiovascular Research Center, 4Tuberculosis and Lung Disease Research Center, Tabriz University of Medical Sciences, Tabriz, IranBackground: Coronary artery bypass graft (CABG surgery is one of the most commonly performed surgical procedures worldwide, and it may be accompanied by postoperative neurocognitive impairment. Although this complication has been attributed to the use of cardiopulmonary bypass, it is still a matter of debate whether the switch from on-pump to off-pump technique affects the cognitive function.Objective: The aim of this study was to compare the impact of the on-pump and off-pump techniques on neurocognitive impairment in low-risk CABG surgery groups.Methods: In a descriptive and analytic study, 201 CABG patients with left-ventricular ejection fraction >30%, and without cardiac arrhythmia were enrolled. Before the elective operation, all patients underwent neurological examination and neurocognitive test, Mini-Mental State Examination (MMSE. Two months following the operation, both on- and off-pump, the patients were re-examined by MMSE to detect any neurocognitive impairment.Results: Out of 154 patients included in the study, 95 (61.6% and 59 (38.3% patients were in off-pump and on-pump groups, respectively. Mean age of the patients was 57.17 ± 9.82 years. A 2-month postoperative neurocognitive impairment was detected among 17 patients of on-pump group (28.8% and in 28 cases of off-pump group (29.4% (P = 0.54. The mean postoperative MMSE scores were not comparable between groups (25.01 ± 4.49 in off-pump group versus 23.73 ± 4.88 in on-pump group, P = 0.09.Conclusion: The present study revealed that in low-risk patients undergoing CABG surgery, either the techniques of on-pump or off-pump did not differ

  9. Apparatus for Pumping a Fluid

    Science.gov (United States)

    Boeyen, Robert Van; Reeh, Jonathan

    2013-01-01

    A fluid pump has been developed for mechanically pumped fluid loops for spacecraft thermal control. Lynntech's technology utilizes a proprietary electrochemically driven pumping mechanism. Conventional rotodynamic and displacement pumps typically do not meet the stringent power and operational reliability requirements of space applications. Lynntech's developmental pump is a highly efficient solid-state pump with essentially no rotating or moving components (apart from metal bellows).

  10. Pumping machinery theory and practice

    CERN Document Server

    Badr, Hassan M

    2014-01-01

    Pumping Machinery Theory and Practice comprehensively covers the theoretical foundation and applications of pumping machinery. Key features: Covers characteristics of centrifugal pumps, axial flow pumps and displacement pumpsConsiders pumping machinery performance and operational-type problemsCovers advanced topics in pumping machinery including multiphase flow principles, and two and three-phase flow pumping systemsCovers different methods of flow rate control and relevance to machine efficiency and energy consumptionCovers different methods of flow rate control and relevance to machine effi

  11. 氯吡格雷联用质子泵抑制剂对再次心血管不良事件影响的Meta分析%Clopidogrel plus proton pump inhibitors increases recurrent major adverse cardiac events: A Meta-Analysis

    Institute of Scientific and Technical Information of China (English)

    杨俊; 戴一扬; 张召才; 张彩伢

    2011-01-01

    目的 系统评价氯吡格雷联用质子泵抑制剂对再次发生心血管不良事件(MACE)的影响,为临床用药提供参考依据.方法 通过计算机检索PubMed、MEDLINE数据库、医文网、中国生物医学文献数据库、万方数据库,使用RevMan 4.2软件对已公开发表的有关氯吡格雷单用和联用质子泵抑制剂治疗急性冠状动脉综合征(ACS)且再次心血管不良事件或再次住院患者的临床研究文献进行Meta分析.结果 共纳入8篇临床研究文献,包括51 191例患者,其中氯吡格雷联用质子泵抑制剂治疗(PPI+Clopidogrel组)有18 618例,单用氯吡格雷治疗(Clopidogrel alone组)有32 573例.Meta分析结果显示:Clopidogrel +PPI组再次MACE发生率明显高于Clopidogrel alone组(OR=1.55,95%CI:1.47~1.64,P<0.01).敏感性分析显示该研究结果稳定性较好.结论 氯吡格雷与质子泵抑制剂联合应用可增加患者再次发生心血管不良事件和再次入院的风险.临床医生应谨慎选择联合用药,从而最大限度地降低药物不良反应和心血管不良事件的发生.%Objective To evaluate the effects of clopidogrel plus proton pump inhibitors (PPI) on recurrent major adverse cardiac events (MACE).Methods Databases including PubMed, MEDLINE, METAMED, CBM and Wanfang were searched.Meta- Analysis was conducted with RevMan 4.2 software to analyze published clinical studies on incidence of recurrent MACE and rehospitalization in patients taking clopidogrel, with and without concomitant PPL Results Eight studies covering 51191 patients were included, among which 18618 patients taking clopidogrel plus PPI, 32573 patients taking clopidogrel alone.Result showed thatthe incidence of MACE in clopidogrelplus PPI group was significantly higher than that of clopidogrel alone group (OR = 1.55, 95%CI: 1.47~1.64, P<0.01).The stability of the results was confirmed by subsequent sensitivity analysis.Conclusion Patients taking clopidogrelplus PPI have

  12. Blood transfusion in cardiac surgery: Does the choice of anesthesia or type of surgery matter?

    OpenAIRE

    Nešković Vojislava; Milojević Predrag; Unić-Stojanović Dragana; Slavković Zoran

    2013-01-01

    Background/Aim. In spite of the evidence suggesting a significant morbidity associated with blood transfusions, the use of blood and blood products remain high in cardiac surgery. To successfully minimize the need for blood transfusion, a systematic approach is needed. The aim of this study was to investigate the influence of different anesthetic techniques, general vs combine epidural and general anesthesia, as well as different surgery strategies, on-pump vs off-pump, on postoperative...

  13. Cardiac and systemic haemodynamic complications of liver cirrhosis

    DEFF Research Database (Denmark)

    Henriksen, Jens H; Møller, Søren

    2009-01-01

    Cardiovascular complications of liver cirrhosis include cardiac dysfunction and abnormalities in the central-, splanchnic,- and peripheral circulation. Vasodilatation prevails, but vascular beds with various degrees of reduced and increased haemodynamic resistance are the results of massive...... by physical and pharmacological strain. Cardiac failure is an important cause of mortality after liver transplantation and stressful procedures as insertions of transjugular intrahepatic portal systemic shunt (TIPS), peritoneal venous shunting, and other types of surgery. Improvement of liver function has...... been shown to reverse the cardiovascular complications. The clinical significance is an important topic for future research. At present, no specific treatment can be recommended, and the cardiac failure in cirrhosis should be treated as in non-cirrhotic patients with sodium restriction, diuretics...

  14. Sodium Heat Engine Development Program

    Energy Technology Data Exchange (ETDEWEB)

    Singh, J.P.; Kupperman, D.S.; Majumdar, S.; Dorris, S.; Gopalsami, N.; Dieckman, S.L.; Jaross, R.A.; Johnson, D.L.; Gregar, J.S.; Poeppel, R.B.; Raptis, A.C.; Valentin, R.A.

    1992-01-01

    The Sodium Heat Engine (SHE) is an efficient thermoelectric conversion device which directly generates electricity from a thermally regenerative electrochemical cell that relies on the unique conduction properties of {beta}{double prime}-alumina solid electrolyte (BASE). Laboratory models of a variety of SHE devices have demonstrated the feasibility and efficiency of the system, engineering development of large prototype devices has been slowed by a series of materials and fabrication problems. Failure of the electrolyte tubes has been a recurring problem and a number of possible causes have been postulated. To address these issues, a two-phase engineering development program was undertaken. This report summarizes the final results of the first phase of the program, which included extensive materials characterization activities, a study of applicable nondestructive evaluation methods, an investigation of possible stress states that would contribute to fracture, and certain operational issues associated with the electromagnetic pumps used in the SHE prototype. Mechanical and microstructural evaluation of commercially obtained BASE tubes revealed that they should be adequate for SHE applications and that sodium exposure produced no appreciable deleterious strength effects. Processing activities to produce a more uniform and smaller grain size for the BASE tubes were completed using isostatic pressing, extrusion, and slip casting. Green tubes were sintered by conventional and microwave plasma methods. Of particular interest is the residual stress state in the BASE tubes, and both analysis and nondestructive evaluation methods were employed to evaluate these stresses. X-ray and neutron diffraction experiments were performed to determine the bulk residual stresses in commercially fabricated BASE tubes; however, tube-to-tube variations and variations among the various methods employed did not allow formulation of a definitive definition of the as-fabricated stress state.

  15. Radionuclide kineventriculographic evaluation of the heart pump function in valvular prosthesis

    International Nuclear Information System (INIS)

    The heart pump function was investigated by the methods of radionuclide kineventriculography, standart opaque ventryculography and echocardiography. The statistical analysis revealed lack of correlation for the ejection fraction, determined by the three methods. The methodological advantages of radionuclide kineventriculography are pointed out for exact and objective evaluation of the ejection fraction of the left cardiac ventricle, as well as some limitations in the application of this index in the clinical assessment of the heart pump function in patients, indicated for valvular prosthesis

  16. Thermal energy storage using thermo-chemical heat pump

    International Nuclear Information System (INIS)

    Highlights: ► Understanding of the performance of thermo chemical heat pump. ► Tool for storing thermal energy. ► Parameters that affect the amount of thermal stored energy. ► Lithium chloride has better effect on storing thermal energy. - Abstract: A theoretical study was performed to investigate the potential of storing thermal energy using a heat pump which is a thermo-chemical storage system consisting of water as sorbet, and sodium chloride as the sorbent. The effect of different parameters namely; the amount of vaporized water from the evaporator, the system initial temperature and the type of salt on the increase in temperature of the salt was investigated and hence on the performance of the thermo chemical heat pump. It was found that the performance of the heat pump improves with the initial system temperature, with the amount of water vaporized and with the water remaining in the system. Finally it was also found that lithium chloride salt has higher effect on the performance of the heat pump that of sodium chloride.

  17. Effect of parameter variations on the hemodynamic response under rotary blood pump assistance.

    Science.gov (United States)

    Lim, Einly; Dokos, Socrates; Salamonsen, Robert F; Rosenfeldt, Franklin L; Ayre, Peter J; Lovell, Nigel H

    2012-05-01

    Numerical models, able to simulate the response of the human cardiovascular system (CVS) in the presence of an implantable rotary blood pump (IRBP), have been widely used as a predictive tool to investigate the interaction between the CVS and the IRBP under various operating conditions. The present study investigates the effect of alterations in the model parameter values, that is, cardiac contractility, systemic vascular resistance, and total blood volume on the efficiency of rotary pump assistance, using an optimized dynamic heart-pump interaction model previously developed in our laboratory based on animal experimental measurements obtained from five canines. The effect of mean pump speed and the circulatory perturbations on left and right ventricular pressure volume loops, mean aortic pressure, mean cardiac output, pump assistance ratio, and pump flow pulsatility from both the greyhound experiments and model simulations are demonstrated. Furthermore, the applicability of some of the previously proposed control parameters, that is, pulsatility index (PI), gradient of PI with respect to pump speed, pump differential pressure, and aortic pressure are discussed based on our observations from experimental and simulation results. It was found that previously proposed control strategies were not able to perform well under highly varying circulatory conditions. Among these, control algorithms which rely on the left ventricular filling pressure appear to be the most robust as they emulate the Frank-Starling mechanism of the heart. PMID:22489771

  18. Developments in sodium technology

    International Nuclear Information System (INIS)

    Sodium, because of its good heat transfer and nuclear properties, is used as a coolant in fast reactors. It is also used largely as a reducing agent in pharmaceutical, perfumery and general chemical industries. Its affinity to react with air and water is a strong disadvantage. However, this is fully understood and the design of engineering systems takes care of this aspect. With several experimental and test facilities established over the years in this country and abroad, 'sodium technology' has reached a level of maturity. The design of sodium systems considering all the physical and chemical properties and the development work carried out in this country are broadly covered in this article. (author)

  19. Sodium technology project

    International Nuclear Information System (INIS)

    The 1976 annual report of the subgroup Nuclear Energy of the organisation for Toegepast Natuurwetenschappelijk Onderzoek (TNO) discusses the research program related to the SNR-300 reactor. The program mainly comprises the properties of ferritic and austenitic construction steels, remote methods of repair (e.g. for welding of sodium moistured surfaces), calculational methods in the designing and large-scale testing of components for heat-transfer equipment, the properties of hydrogen in sodium systems (detection of leaks in steam generator pipes), the study of models for mass transport in sodium, wear and mechanical damage of pipes in heat exchangers

  20. Fibroblast growth factor homologous factors in the heart: a potential locus for cardiac arrhythmias.

    Science.gov (United States)

    Wei, Eric Q; Barnett, Adam S; Pitt, Geoffrey S; Hennessey, Jessica A

    2011-10-01

    The four fibroblast growth factor homologous factors (FHFs; FGF11-FGF14) are intracellular proteins that bind and modulate voltage-gated sodium channels (VGSCs). Although FHFs have been well studied in neurons and implicated in neurologic disease, their role in cardiomyocytes was unclear until recently. This review discusses the expression profile and function of FHFs in mouse and rat ventricular cardiomyocytes. Recent data show that FGF13 is the predominant FHF in the murine heart, directly binds the cardiac VGSC α subunit, and is essential for normal cardiac conduction. FHF loss-of-function mutations may be unrecognized causes of cardiac arrhythmias, such as long QT and Brugada syndromes.

  1. Crystal structure of the plasma membrane proton pump

    DEFF Research Database (Denmark)

    Pedersen, Bjørn P.; Buch-Pedersen, Morten Jeppe; Morth, J. Preben;

    2007-01-01

    -3, and Na1,K1-ATPase (the sodium-potassium pump) in animals4. The name P-type derives from the fact that these proteins exploit a phosphorylated reaction cycle intermediate of ATP hydrolysis5.The plasma membrane proton pumps belong to the type III P-type ATPase subfamily, whereas Na1,K1-ATPase and Ca21...... where it is lined by conserved hydrophilic and charged residues. Proton transport against a high membrane potential is readily explained by this structural arrangement....

  2. Finite Element Model to Study One Dimensional Calcium Dyanmics in Cardiac Myocytes

    Science.gov (United States)

    Pathak, Kunal B.; Adlakha, Neeru

    2015-12-01

    The multi physical process involving calcium ions regulate expansion and contraction of cardiac myocytes. This mechanism of expansion and contraction of cardiac myocytes is responsible for contraction and expansion of heart for pumping of blood into arteries and receiving blood into heart from vein. Thus calcium dynamics in cardiac myocytes is responsible for the activities of the myocytes cells and functioning of the heart. The specific spatiotemporal calcium ion dynamics is required to trigger, sustain and terminate activity of the cell. In this paper an attempt has been done to propose a model to study calcium dynamics in cardiac myocytes for a one-dimensional unsteady state case. The model incorporates the process like diffusion, reaction involving source and excess buffers. Appropriate boundary conditions and initial conditions have been framed. The finite element method has been employed to obtain the solution. The numerical results have been used to study the effect of buffers and source influx on calcium dynamics in cardiac myocytes.

  3. Natural convection test in secondary sodium circuits of FBTR

    International Nuclear Information System (INIS)

    Fast Breeder Test Reactor (FBTR) is presently operating at a maximum power level of 10 MWt. Several engineering tests have been carried out on the plant and one amongst them is the secondary sodium pumps alone tripped natural convection test at a low power of 180 kW without manipulation of control rods. The purpose of this test is to demonstrate the natural convection capability of the secondary sodium system and the reactor's favourable intrinsic reactivity feedback effects. 7 refs., 5 figs., 1 tab

  4. Analyses of annular linear induction pump characteristics using a time-harmonic finite difference analysis

    International Nuclear Information System (INIS)

    The pumping of coolant in a liquid metal fast reactor may be performed with an annular linear induction Electro-Magnetic (EM) pump. Linear induction pumps use a traveling magnetic field wave created by poly-phase currents, and the induced currents and their associated magnetic field generate a Lorentz force, whose effect can be the pumping of the liquid metal. The flow behaviors in the pump are very complex, including a time-varying Lorentz force and pressure pulsation, because an induction EM pump has time-varying magnetic fields and the induced convective currents that originate from the flow of the liquid metal. These phenomena lead to an instability problem in the pump arising from the changes of the generated Lorentz forces along the pump's geometry. Therefore, a Magneto-Hydro-Dynamics (MHD) analysis is required for the design and operation of a linear induction EM pump. We have developed a time-harmonic 2-dimensional axisymmetry MHD analysis method based on the Maxwell equations. This paper describes the analysis and numerical method for obtaining solutions for some MHD parameters in an induction EM pump. Experimental test results obtained from an induction EM pump of CLIP-150 at the STC 'Sintez,' D.V. Efremov Institute of Electro-physical Apparatus in St. Petersburg were used to validate the method. In addition, we investigated some characteristics of a linear induction EM pump, such as the effect of the convective current and the Double Supply Frequency (DSF) pressure pulsation. This simple model overestimated the convective eddy current generated from the sodium flow in the pump channel; however, it had a similar tendency for the measured data of the pump performance through a comparison with the experimental data. Considering its simplicity, it could be a base model for designing an EM pump and for evaluating the MHD flow in an EM pump

  5. Combined Application of Circulatory Assist Devices Following Cardiac Arrest in Patients after Cardiac Surgery

    Institute of Scientific and Technical Information of China (English)

    Huang Huanlei; Xiao Xuejun; Wu Ruobin; Ruixin; Cheng Anheng; Zhang Xiaohua; Luo Zhengxiang

    2006-01-01

    Objectives To evaluateretrospectively the potential benefits of combined utilization of various assisted circulation devices in cardiac arrest patients who did not respond to conventional cardiopulmonary cerebral resuscitation (CPCR). Methods Assisted circulation devices,including emergency cardiopulmonary bypass (ECPB), intra-aortic balloon pump (IABP), and left ventricular assist device (LVAD), were applied to 16 adult patients who had cardiac arrest 82 min~56 h after open heart surgery and did not respond to 20 min or longer conventional CPCR. ECPB was applied to 2 patients, ECPB plus IABP to 8 patients, ECPB plus IABP and LVAD to 6 patients. Results One patient recovered fully and one patient died. Of the other 14 patients, 13 resumed spontaneous cardiac rhythm and one did not; none of them could be weaned from ECPB.Further treatment of the 14 patients with combinations of assisted circulation devices enabled 6 patients to recover. One of the 7 recovered patients died of reoccurring cardiac arrest after 11 days; the other 6 were discharged in good condition and were followed up for 3~49 months (mean =22 months). Of the 6 discharged patients one suffered cerebral embolism during LVAD treatment, resulting in mild limitation of mobility of the right limbs; the other 5 never manifested any central nervous system complications. There was no late deaths giving a 37.5% (6/16) long-term survival rate. Conclusions ECPB could effectively reestablish blood circulation and oxygen supply, rectify acidosis,and improve internal milieu. The combined utilization of ECPB, IABP, and LVAD reduces the duration of ECPB, improves the incidence of recovery, and offers beneficial alternatives to refractory cardiac arrest patients.

  6. Regenerative Hydride Heat Pump

    Science.gov (United States)

    Jones, Jack A.

    1992-01-01

    Hydride heat pump features regenerative heating and single circulation loop. Counterflow heat exchangers accommodate different temperatures of FeTi and LaNi4.7Al0.3 subloops. Heating scheme increases efficiency.

  7. Advanced heat pump

    Science.gov (United States)

    Ashley, Joseph L.; Matthews, John D.

    1989-09-01

    This patent application discloses a heat pump which includes a first packed bed of liquid desiccant for removing moisture from outside air in the heating mode of operation, and a pump for transferring the moisture laden desiccant to a second packed bed which humidifies condenser heated inside air by adding water vapor to the air. The first packed bed, by removing moisture from the outside air before it passes through the heat pump's evaporator coils, prevents frost from forming on the coils. In the cooling mode of operation the second packed bed of liquid desiccant removes water vapor from the air inside of the building. The moisture laden desiccant is then transferred to the first packed bed by a second pump where condenser heat transfers the moisture from the desiccant to outside air.

  8. High Voltage Charge Pump

    KAUST Repository

    Emira, Ahmed A.

    2014-10-09

    Various embodiments of a high voltage charge pump are described. One embodiment is a charge pump circuit that comprises a plurality of switching stages each including a clock input, a clock input inverse, a clock output, and a clock output inverse. The circuit further comprises a plurality of pumping capacitors, wherein one or more pumping capacitors are coupled to a corresponding switching stage. The circuit also comprises a maximum selection circuit coupled to a last switching stage among the plurality of switching stages, the maximum selection circuit configured to filter noise on the output clock and the output clock inverse of the last switching stage, the maximum selection circuit further configured to generate a DC output voltage based on the output clock and the output clock inverse of the last switching stage.

  9. Nuclear-pumped lasers

    CERN Document Server

    Prelas, Mark

    2016-01-01

    This book focuses on Nuclear-Pumped Laser (NPL) technology and provides the reader with a fundamental understanding of NPLs, a review of research in the field, and exploration of large scale NPL system design and applications. Early chapters look at the fundamental properties of lasers, nuclear-pumping and nuclear reactions that may be used as drivers for nuclear-pumped lasers. The book goes on to explore the efficient transport of energy from the ionizing radiation to the laser medium and then the operational characteristics of existing nuclear-pumped lasers. Models based on Mathematica, explanations and a tutorial all assist the reader’s understanding of this technology. Later chapters consider the integration of the various systems involved in NPLs and the ways in which they can be used, including beyond the military agenda. As readers will discover, there are significant humanitarian applications for high energy/power lasers, such as deflecting asteroids, space propulsion, power transmission and mining....

  10. Keeping Hearts Pumping

    Science.gov (United States)

    2002-01-01

    A collaboration between NASA, Dr. Michael DeBakey, Dr. George Noon, and MicroMed Technology, Inc., resulted in a life-saving heart pump for patients awaiting heart transplants. The MicroMed DeBakey VAD functions as a "bridge to heart transplant" by pumping blood throughout the body to keep critically ill patients alive until a donor heart is available. Weighing less than 4 ounces and measuring 1 inch by 3 inches, the pump is approximately one-tenth the size of other currently marketed pulsatile VADs. This makes it less invasive and ideal for smaller adults and children. Because of the pump's small size, less than 5 percent of the patients implanted developed device-related infections. It can operate up to 8 hours on batteries, giving patients the mobility to do normal, everyday activities.The MicroMed DeBakey VAD is a registered trademark of MicroMed Technology, Inc.

  11. Pediatric cardiac postoperative care

    Directory of Open Access Journals (Sweden)

    Auler Jr. José Otávio Costa

    2002-01-01

    Full Text Available The Heart Institute of the University of São Paulo, Medical School is a referral center for the treatment of congenital heart diseases of neonates and infants. In the recent years, the excellent surgical results obtained in our institution may be in part due to modern anesthetic care and to postoperative care based on well-structured protocols. The purpose of this article is to review unique aspects of neonate cardiovascular physiology, the impact of extracorporeal circulation on postoperative evolution, and the prescription for pharmacological support of acute cardiac dysfunction based on our cardiac unit protocols. The main causes of low cardiac output after surgical correction of heart congenital disease are reviewed, and methods of treatment and support are proposed as derived from the relevant literature and our protocols.

  12. Sodium carbonate poisoning

    Science.gov (United States)

    Sodium carbonate is found in: Automatic dishwashing soaps Clinitest (diabetes testing) tablets Glass products Pulp and paper products Some bleaches Some bubble bath solutions Some steam iron cleaners Note: This list is not all-inclusive.

  13. Fractional excretion of sodium

    Science.gov (United States)

    ... skin) Infection (a slight risk any time the skin is broken) Multiple punctures to locate veins There are no risks with the urine sample. Alternative Names FE sodium; FENa Images Male urinary system References Parikh CR, ...

  14. Sodium urine test

    Science.gov (United States)

    ... urine sodium level may be a sign of: Adrenal glands releasing too much hormone ( hyperaldosteronism ) Not enough fluid in the body (dehydration) Diarrhea and fluid loss Heart failure Kidney problems, such as chronic kidney disease or ...

  15. Tokamak pump limiters

    International Nuclear Information System (INIS)

    Recent experiments with a scoop limiter without active internal pumping have been carried out in the PDX tokamak with up to 6MW of auxiliary neutral beam heating. Experiments have also been done with a rotating head pump limiter in the PLT tokamak in conjunction with RF plasma heating. Extensive experiments have been done in the ISX-B tokamak and first experiments have been completed with the ALT-I limiter in TEXTOR. The pump limiter modules in these latter two machines have internal getter pumping. Experiments in ISX-B are with ohmic and auxiliary neutral beam heating. The results in ISX-B and TEXTOR show that active density control and particle removal is achieved with pump limiters. In ISX-B, the boundary layer (or scape-off layer) plasma partially screens the core plasma from gas injection. In both ISX-B and TEXTOR, the pressure internal to the module scales linearly with plasma density but in ISX-B, with neutral beam injection, a nonlinear increase is observed at the highest densities studied. Plasma plugging is the suspected cause. Results from PDX suggest that a region may exist in which core plasma energy confinement improves using a pump limiter during neutral beam injection. Asymmetric radial profiles and an increased edge electron temperature are observed in discharges with improved confinement. The injection of small amounts of neon into ISX-B has more clearly shown an improved electron core energy confinement during neutral beam injection. While carried out with a regular limiter, this Z-mode of operation is ideal for use with pump limiters and should be a way to achieve energy confinement times similar to values for H-mode tokamak plasmas. The implication of all these results for the design of a reactor pump limiter is described

  16. Lunar Base Heat Pump

    Science.gov (United States)

    Walker, D.; Fischbach, D.; Tetreault, R.

    1996-01-01

    The objective of this project was to investigate the feasibility of constructing a heat pump suitable for use as a heat rejection device in applications such as a lunar base. In this situation, direct heat rejection through the use of radiators is not possible at a temperature suitable for lde support systems. Initial analysis of a heat pump of this type called for a temperature lift of approximately 378 deg. K, which is considerably higher than is commonly called for in HVAC and refrigeration applications where heat pumps are most often employed. Also because of the variation of the rejection temperature (from 100 to 381 deg. K), extreme flexibility in the configuration and operation of the heat pump is required. A three-stage compression cycle using a refrigerant such as CFC-11 or HCFC-123 was formulated with operation possible with one, two or three stages of compression. Also, to meet the redundancy requirements, compression was divided up over multiple compressors in each stage. A control scheme was devised that allowed these multiple compressors to be operated as required so that the heat pump could perform with variable heat loads and rejection conditions. A prototype heat pump was designed and constructed to investigate the key elements of the high-lift heat pump concept. Control software was written and implemented in the prototype to allow fully automatic operation. The heat pump was capable of operation over a wide range of rejection temperatures and cooling loads, while maintaining cooling water temperature well within the required specification of 40 deg. C +/- 1.7 deg. C. This performance was verified through testing.

  17. Sodium bicarbonate and sodium citrate: ergogenic aids?

    Science.gov (United States)

    Requena, Bernardo; Zabala, Mikel; Padial, Paulino; Feriche, Belén

    2005-02-01

    Numerous studies have used exogenous administration of sodium bicarbonate (NaHCO(3)) and sodium citrate (Na-citrate) in an attempt to enhance human performance. After ingestion of NaHCO(3) and Na-citrate, two observations have been made: (a) There was great individual variability in the ergogenic benefit reached, which can be attributed to the level of physical conditioning of the subjects and to their tolerance of the buffer substance; and (b) the subjects who had ingested NaHCO(3) and Na-citrate show higher levels of pH, bicarbonate, and lactate ions concentrations in their exercising blood than do the subjects who had ingested the placebo. A majority of the studies have suggested that the ingestion of both substances provides an ergogenic effect due to the establishment and maintenance of an elevated pH level during exercise. However, the exact mechanism by which the ergogenic effects occur has not been demonstrated conclusively. Sodium bicarbonate and Na-citrate seem to be effective in activities with a sufficient duration to generate a difference in the hydrogen ion gradient, characterized by a very high intensity and involving large muscular groups. However, in activities of equally high intensity, but with longer duration, the results obtained have been conflicting and inconclusive. PMID:15705037

  18. The cardiac anxiety questionnaire: cross-validation among cardiac inpatients

    NARCIS (Netherlands)

    Beek, M.H. van; Oude Voshaar, R.C.; Deelen, F.M. van; Balkom, A.J. van; Pop, G.A.; Speckens, A.E.

    2012-01-01

    OBJECTIVE: General anxiety symptoms are common in patients with cardiac disease and considered to have an adverse effect on cardiac prognosis. The role of specific cardiac anxiety, however, is still unknown. The aim of this study is to examine the factor structure, reliability, and validity of the D

  19. THE CARDIAC ANXIETY QUESTIONNAIRE : CROSS-VALIDATION AMONG CARDIAC INPATIENTS

    NARCIS (Netherlands)

    van Beek, M. H. C. T.; Voshaar, R. C. Oude; van Deelen, F. M.; van Balkom, A. J. L. M.; Pop, G.; Speckens, A. E. M.

    2012-01-01

    Objective: General anxiety symptoms are common in patients with cardiac disease and considered to have an adverse effect on cardiac prognosis. The role of specific cardiac anxiety, however, is still unknown. The aim of this study is to examine the factor structure, reliability, and validity of the D

  20. Rotary blood pump

    Science.gov (United States)

    Benkowski, Robert J. (Inventor); Kiris, Cetin (Inventor); Kwak, Dochan (Inventor); Rosenbaum, Bernard J. (Inventor); Bacak, James W. (Inventor); DeBakey, Michael E. (Inventor)

    1999-01-01

    A blood pump that comprises a pump housing having a blood flow path therethrough, a blood inlet, and a blood outlet; a stator mounted to the pump housing, the stator having a stator field winding for producing a stator magnetic field; a flow straightener located within the pump housing, and comprising a flow straightener hub and at least one flow straightener blade attached to the flow straightener hub; a rotor mounted within the pump housing for rotation in response to the stator magnetic field, the rotor comprising an inducer and an impeller; the inducer being located downstream of the flow straightener, and comprising an inducer hub and at least one inducer blade attached to the inducer hub; the impeller being located downstream of the inducer, and comprising an impeller hub and at least one impeller blade attached to the impeller hub; and preferably also comprising a diffuser downstream of the impeller, the diffuser comprising a diffuser hub and at least one diffuser blade. Blood flow stagnation and clot formation within the pump are minimized by, among other things, providing the inducer hub with a diameter greater than the diameter of the flow straightener hub; by optimizing the axial spacing between the flow straightener hub and the inducer hub, and between the impeller hub and the diffuser hub; by optimizing the inlet angle of the diffuser blades; and by providing fillets or curved transitions between the upstream end of the inducer hub and the shaft mounted therein, and between the impeller hub and the shaft mounted therein.

  1. Giant Cardiac Cavernous Hemangioma.

    Science.gov (United States)

    Unger, Eric; Costic, Joseph; Laub, Glenn

    2015-07-01

    We report the case of an asymptomatic giant cardiac cavernous hemangioma in a 71-year-old man. The intracardiac mass was discovered incidentally during surveillance for his prostate cancer; however, the patient initially declined intervention. On presentation to our institution 7 years later, the lesion had enlarged significantly, and the patient consented to excision. At surgery, an 8 × 6.5 × 4.8 cm intracardiac mass located on the inferior heart border was excised with an intact capsule through a median sternotomy approach. The patient had an uneventful postoperative course. We discuss the diagnostic workup, treatment, and characteristics of this rare cardiac tumor. PMID:26140782

  2. Perioperative management of cardiac disease.

    Science.gov (United States)

    Aresti, N A; Malik, A A; Ihsan, K M; Aftab, S M E; Khan, W S

    2014-01-01

    Pre-existing cardiac disease contributes significantly to morbidity and mortality amongst patients undergoing non cardiac surgery. Patients with pre-existing cardiac disease or with risk factors for it, have as much as a 3.9% risk of suffering a major perioperative cardiac event (Lee et al 1999, Devereaux 2005). Furthermore, the incidence of perioperative myocardial infarction (MI) is increased 10 to 50 fold in patients with previous coronary events (Jassal 2008).

  3. Design of a Mechanical NaK Pump for Fission Space Power

    Science.gov (United States)

    Mireles, Omar R.; Bradley, David E.; Godfroy, Thomas

    2011-01-01

    Alkali liquid metal cooled fission reactor concepts are under development for spaceflight power requirements. One such concept utilizes a sodium-potassium eutectic (NaK) as the primary loop working fluid, which has specific pumping requirements. Traditionally, electromagnetic linear induction pumps have been used to provide the required flow and pressure head conditions for NaK systems but they can be limited in performance, efficiency, and number of available vendors. The objective of the project was to develop a mechanical NaK centrifugal pump that takes advantages of technology advances not available in previous liquid metal mechanical pump designs. This paper details the design, build, and performance test of a mechanical NaK pump developed at NASA Marshall Space Flight Center. The pump was designed to meet reactor cooling requirements using commercially available components modified for high temperature NaK service.

  4. Thermally Actuated Hydraulic Pumps

    Science.gov (United States)

    Jones, Jack; Ross, Ronald; Chao, Yi

    2008-01-01

    Thermally actuated hydraulic pumps have been proposed for diverse applications in which direct electrical or mechanical actuation is undesirable and the relative slowness of thermal actuation can be tolerated. The proposed pumps would not contain any sliding (wearing) parts in their compressors and, hence, could have long operational lifetimes. The basic principle of a pump according to the proposal is to utilize the thermal expansion and contraction of a wax or other phase-change material in contact with a hydraulic fluid in a rigid chamber. Heating the chamber and its contents from below to above the melting temperature of the phase-change material would cause the material to expand significantly, thus causing a substantial increase in hydraulic pressure and/or a substantial displacement of hydraulic fluid out of the chamber. Similarly, cooling the chamber and its contents from above to below the melting temperature of the phase-change material would cause the material to contract significantly, thus causing a substantial decrease in hydraulic pressure and/or a substantial displacement of hydraulic fluid into the chamber. The displacement of the hydraulic fluid could be used to drive a piston. The figure illustrates a simple example of a hydraulic jack driven by a thermally actuated hydraulic pump. The pump chamber would be a cylinder containing encapsulated wax pellets and containing radial fins to facilitate transfer of heat to and from the wax. The plastic encapsulation would serve as an oil/wax barrier and the remaining interior space could be filled with hydraulic oil. A filter would retain the encapsulated wax particles in the pump chamber while allowing the hydraulic oil to flow into and out of the chamber. In one important class of potential applications, thermally actuated hydraulic pumps, exploiting vertical ocean temperature gradients for heating and cooling as needed, would be used to vary hydraulic pressures to control buoyancy in undersea research

  5. Volume and its relationship to cardiac output and venous return.

    Science.gov (United States)

    Magder, S

    2016-09-10

    Volume infusions are one of the commonest clinical interventions in critically ill patients yet the relationship of volume to cardiac output is not well understood. Blood volume has a stressed and unstressed component but only the stressed component determines flow. It is usually about 30 % of total volume. Stressed volume is relatively constant under steady state conditions. It creates an elastic recoil pressure that is an important factor in the generation of blood flow. The heart creates circulatory flow by lowering the right atrial pressure and allowing the recoil pressure in veins and venules to drain blood back to the heart. The heart then puts the volume back into the systemic circulation so that stroke return equals stroke volume. The heart cannot pump out more volume than comes back. Changes in cardiac output without changes in stressed volume occur because of changes in arterial and venous resistances which redistribute blood volume and change pressure gradients throughout the vasculature. Stressed volume also can be increased by decreasing vascular capacitance, which means recruiting unstressed volume into stressed volume. This is the equivalent of an auto-transfusion. It is worth noting that during exercise in normal young males, cardiac output can increase five-fold with only small changes in stressed blood volume. The mechanical characteristics of the cardiac chambers and the circulation thus ultimately determine the relationship between volume and cardiac output and are the subject of this review.

  6. Hydrogen generation systems utilizing sodium silicide and sodium silica gel materials

    Science.gov (United States)

    Wallace, Andrew P.; Melack, John M.; Lefenfeld, Michael

    2015-07-14

    Systems, devices, and methods combine reactant materials and aqueous solutions to generate hydrogen. The reactant materials can sodium silicide or sodium silica gel. The hydrogen generation devices are used in fuels cells and other industrial applications. One system combines cooling, pumping, water storage, and other devices to sense and control reactions between reactant materials and aqueous solutions to generate hydrogen. Multiple inlets of varied placement geometries deliver aqueous solution to the reaction. The reactant materials and aqueous solution are churned to control the state of the reaction. The aqueous solution can be recycled and returned to the reaction. One system operates over a range of temperatures and pressures and includes a hydrogen separator, a heat removal mechanism, and state of reaction control devices. The systems, devices, and methods of generating hydrogen provide thermally stable solids, near-instant reaction with the aqueous solutions, and a non-toxic liquid by-product.

  7. Hydrogen generation systems and methods utilizing sodium silicide and sodium silica gel materials

    Science.gov (United States)

    Wallace, Andrew P.; Melack, John M.; Lefenfeld, Michael

    2015-08-11

    Systems, devices, and methods combine thermally stable reactant materials and aqueous solutions to generate hydrogen and a non-toxic liquid by-product. The reactant materials can sodium silicide or sodium silica gel. The hydrogen generation devices are used in fuels cells and other industrial applications. One system combines cooling, pumping, water storage, and other devices to sense and control reactions between reactant materials and aqueous solutions to generate hydrogen. Springs and other pressurization mechanisms pressurize and deliver an aqueous solution to the reaction. A check valve and other pressure regulation mechanisms regulate the pressure of the aqueous solution delivered to the reactant fuel material in the reactor based upon characteristics of the pressurization mechanisms and can regulate the pressure of the delivered aqueous solution as a steady decay associated with the pressurization force. The pressure regulation mechanism can also prevent hydrogen gas from deflecting the pressure regulation mechanism.

  8. In vitro evaluation of the TandemHeart pediatric centrifugal pump.

    Science.gov (United States)

    Svitek, Robert G; Smith, Douglas E; Magovern, James A

    2007-01-01

    The pediatric TandemHeart pump is being developed for short-term circulatory support of patients varying in size from 2 to 40 kg. The pump withdraws blood from the left atrium via cannula inserted percutaneously, either through the right internal jugular vein or transhepatically, and pumps the blood back into the arterial system via the carotid or femoral artery. High resolution stereolithography (SLA) was used to create an upper housing and impeller design, which were assembled into a functional pump prototype. Pressure-flow characteristics of the pump were determined in a blood analogue solution and compared with the pressure-flow requirements of the intended cannulation. At 5,500 rpm, the pump was able to generate 0.4 L/min of flow with a pressure rise of 325 mm Hg and 2.0 L/min with a pressure rise of 250 mm Hg. The hydraulic performance of the pump will enable at least 50% of cardiac output when the arterial cannula is placed in the carotid artery. The hemolysis of the TandemHeart pediatric pump at 5,500 rpm was compared with the BP-50 pediatric centrifugal pump in vitro using bovine blood flowing at 0.4 L/min against 250 mm Hg. The TandemHeart pump produced a similar increase in plasma free hemoglobin levels during the duration of the 6 hour test.

  9. Current Pharmacological Advances in the Treatment of Cardiac Arrest

    Directory of Open Access Journals (Sweden)

    Andry Papastylianou

    2012-01-01

    Full Text Available Cardiac arrest is defined as the sudden cessation of spontaneous ventilation and circulation. Within 15 seconds of cardiac arrest, the patient loses consciousness, electroencephalogram becomes flat after 30 seconds, pupils dilate fully after 60 seconds, and cerebral damage takes place within 90–300 seconds. It is essential to act immediately as irreversible damage can occur in a short time. Cardiopulmonary resuscitation (CPR is an attempt to restore spontaneous circulation through a broad range of interventions which are early defibrillation, high-quality and uninterrupted chest compressions, advanced airway interventions, and pharmacological interventions. Drugs should be considered only after initial shocks have been delivered (when indicated and chest compressions and ventilation have been started. During cardiopulmonary resuscitation, no specific drug therapy has been shown to improve survival to hospital discharge after cardiac arrest, and only few drugs have a proven benefit for short-term survival. This paper reviews current pharmacological treatment of cardiac arrest. There are three groups of drugs relevant to the management of cardiac arrest: vasopressors, antiarrhythmics, and other drugs such as sodium bicarbonate, calcium, magnesium, atropine, fibrinolytic drugs, and corticosteroids.

  10. Severe hyperkalaemia and ketoacidosis during routine treatment with an insulin pump.

    OpenAIRE

    Knight, G; Jennings, A M; Boulton, A J; Tomlinson, S; Ward, J.D.

    1985-01-01

    During a feasibility study of the use of insulin pumps to treat diabetes ketoacidosis occurred at a rate of 0.14 episodes/patient/year in the first year but was lower in subsequent years. A case of cardiac arrest secondary to hyperkalaemia during ketoacidosis occurred in a patient treated with a pump. The mean (SD) serum potassium concentration on presentation to hospital with ketoacidosis was significantly higher in patients treated with a pump (5.7 (1.1) mmol(mEq)/l) than those treated with...

  11. Electronic Unit Pump Test Bench Development and Pump Properties Research

    Institute of Scientific and Technical Information of China (English)

    LIU Bo-lan; HUANG Ying; ZHANG Fu-jun; ZHAO Chang-lu

    2006-01-01

    A unit pump test bench is developed on an in-line pump test platform. The bench is composed of pump adapting assembly, fuel supply subsystem, lubricating subsystem and a control unit. A crank angle domain injection control method is given out and the control accuracy can be 0.1° crank degree. The bench can test bot h mechanical unit pump and electronic unit pump. A test model-PLD12 electronic unit pump is tested. Full pump delivery map and some influence factors test is d one. Experimental results show that the injection quantity is linear with the de livery angle. The quantity change rate is 15% when fuel temperature increases 30℃. The delivery quantity per cycle increases 30mg at 28V drive voltage. T he average delivery difference for two same type pumps is 5%. Test results show that the bench can be used for unit pump verification.

  12. The cardiac malpositions.

    Science.gov (United States)

    Perloff, Joseph K

    2011-11-01

    Dextrocardia was known in the 17th century and was 1 of the first congenital malformations of the heart to be recognized. Fifty years elapsed before Matthew Baillie published his account of complete transposition in a human of the thoracic and abdominal viscera to the opposite side from what is natural. In 1858, Thomas Peacock stated that "the heart may be congenitally misplaced in various ways, occupying either an unusual position within the thorax, or being situated external to that cavity." In 1915, Maude Abbott described ectopia cordis, and Richard Paltauf's remarkable illustrations distinguished the various types of dextrocardia. In 1928, the first useful classification of the cardiac malpositions was proposed, and in 1966, Elliott et al's radiologic classification set the stage for clinical recognition. The first section of this review deals with the 3 basic cardiac malpositions in the presence of bilateral asymmetry. The second section deals with cardiac malpositions in the presence of bilateral left-sidedness or right-sidedness. Previous publications on cardiac malpositions are replete with an arcane vocabulary that confounds rather than clarifies. Even if the terms themselves are understood, inherent complexity weighs against clarity. This review was designed as a guided tour of an unfamiliar subject.

  13. Hepato-cardiac disorders

    Institute of Scientific and Technical Information of China (English)

    Yasser; Mahrous; Fouad; Reem; Yehia

    2014-01-01

    Understanding the mutual relationship between the liver and the heart is important for both hepatologists and cardiologists. Hepato-cardiac diseases can be classified into heart diseases affecting the liver, liver diseases affecting the heart, and conditions affecting the heart and the liver at the same time. Differential diagnoses of liver injury are extremely important in a cardiologist’s clinical practice calling for collaboration between cardiologists and hepatologists due to the many other diseases that can affect the liver and mimic haemodynamic injury. Acute and chronic heart failure may lead to acute ischemic hepatitis or chronic congestive hepatopathy. Treatment in these cases should be directed to the primary heart disease. In patients with advanced liver disease, cirrhotic cardiomyopathy may develop including hemodynamic changes, diastolic and systolic dysfunctions, reduced cardiac performance and electrophysiological abnormalities. Cardiac evaluation is important for patients with liver diseases especially before and after liver transplantation. Liver transplantation may lead to the improvement of all cardiac changes and the reversal of cirrhotic cardiomyopathy. There are systemic diseases that may affect both the liver and the heart concomitantly including congenital, metabolic and inflammatory diseases as well as alcoholism. This review highlights these hepatocardiac diseases

  14. Cardiac effects of vasopressin.

    Science.gov (United States)

    Pelletier, Jean-Sébastien; Dicken, Bryan; Bigam, David; Cheung, Po-Yin

    2014-07-01

    Vasopressin is an essential hormone involved in the maintenance of cardiovascular homeostasis. It has been in use therapeutically for many decades, with an emphasis on its vasoconstrictive and antidiuretic properties. However, this hormone has a ubiquitous influence and has specific effects on the heart. Although difficult to separate from its powerful vascular effects in the clinical setting, a better understanding of vasopressin's direct cardiac effects could lead to its more effective clinical use for a variety of shock states by maximizing its therapeutic benefit. The cardiac-specific effects of vasopressin are complex and require further elucidation. Complicating our understanding include the various receptors and secondary messengers involved in vasopressin's effects, which may lead to various results based on differing doses and varying environmental conditions. Thus, there have been contradictory reports on vasopressin's action on the coronary vasculature and on its effect on inotropy. However, beneficial results have been found and warrant further study to expand the potential therapeutic role of vasopressin. This review outlines the effect of vasopressin on the coronary vasculature, cardiac contractility, and on hypertrophy and cardioprotection. These cardiac-specific effects of vasopressin represent an interesting area for further study for potentially important therapeutic benefits. PMID:24621650

  15. Cardiac potassium channel subtypes

    DEFF Research Database (Denmark)

    Schmitt, Nicole; Grunnet, Morten; Olesen, Søren-Peter

    2014-01-01

    About 10 distinct potassium channels in the heart are involved in shaping the action potential. Some of the K(+) channels are primarily responsible for early repolarization, whereas others drive late repolarization and still others are open throughout the cardiac cycle. Three main K(+) channels...

  16. Cardiac pacemaker power sources

    International Nuclear Information System (INIS)

    A review of chemical and radioisotope batteries used in cardiac pacemakers is presented. The battery systems are examined in terms of longevity, reliability, cost, size and shape, energy density, weight, internal resistance versus time, end-of-life voltage, chemical compatibility, and potential failure mechanisms

  17. Collision Kernels from Velocity-Selective Optical Pumping with Magnetic Depolarization

    CERN Document Server

    Bhamre, T; Kominis, I K; McGuyer, B H; Happer, W

    2013-01-01

    We experimentally demonstrate how magnetic depolarization of velocity-selective optical pumping can be used to single out the collisional cusp kernel best describing spin and velocity relaxing collisions between potassium atoms and low pressure helium. The range of pressures and transverse fields used simulate the novel optical pumping regime pertinent to sodium guidestars employed in adaptive optics. We measure the precession of spin-velocity modes under the application of transverse magnetic fields, simulating the natural configuration of mesospheric sodium optical pumping in the geomagnetic field. We also provide a full theoretical account of the experimental data using the recently developed cusp kernels, which realistically quantify velocity damping collisions in this novel optical pumping regime. A single cusp kernel with a sharpness $s=13\\pm 2$ provides a global fit to the K-He data.

  18. Underground pumped hydroelectric storage

    Energy Technology Data Exchange (ETDEWEB)

    Allen, R.D.; Doherty, T.J.; Kannberg, L.D.

    1984-07-01

    Underground pumped hydroelectric energy storage was conceived as a modification of surface pumped storage to eliminate dependence upon fortuitous topography, provide higher hydraulic heads, and reduce environmental concerns. A UPHS plant offers substantial savings in investment cost over coal-fired cycling plants and savings in system production costs over gas turbines. Potential location near load centers lowers transmission costs and line losses. Environmental impact is less than that for a coal-fired cycling plant. The inherent benefits include those of all pumped storage (i.e., rapid load response, emergency capacity, improvement in efficiency as pumps improve, and capacity for voltage regulation). A UPHS plant would be powered by either a coal-fired or nuclear baseload plant. The economic capacity of a UPHS plant would be in the range of 1000 to 3000 MW. This storage level is compatible with the load-leveling requirements of a greater metropolitan area with population of 1 million or more. The technical feasibility of UPHS depends upon excavation of a subterranean powerhouse cavern and reservoir caverns within a competent, impervious rock formation, and upon selection of reliable and efficient turbomachinery - pump-turbines and motor-generators - all remotely operable.

  19. Heat driven pulse pump

    Science.gov (United States)

    Benner, Steve M (Inventor); Martins, Mario S. (Inventor)

    2000-01-01

    A heat driven pulse pump includes a chamber having an inlet port, an outlet port, two check valves, a wick, and a heater. The chamber may include a plurality of grooves inside wall of the chamber. When heated within the chamber, a liquid to be pumped vaporizes and creates pressure head that expels the liquid through the outlet port. As liquid separating means, the wick, disposed within the chamber, is to allow, when saturated with the liquid, the passage of only liquid being forced by the pressure head in the chamber, preventing the vapor from exiting from the chamber through the outlet port. A plurality of grooves along the inside surface wall of the chamber can sustain the liquid, which is amount enough to produce vapor for the pressure head in the chamber. With only two simple moving parts, two check valves, the heat driven pulse pump can effectively function over the long lifetimes without maintenance or replacement. For continuous flow of the liquid to be pumped a plurality of pumps may be connected in parallel.

  20. Redox-dependent regulation of the Na⁺-K⁺ pump

    DEFF Research Database (Denmark)

    Liu, Chia-Chi; Fry, Natasha A S; Hamilton, Elisha J;

    2013-01-01

    By the time it was appreciated that the positive inotropic effect of cardiac glycosides is due to inhibition of the membrane Na(+)-K(+) pump, glycosides had been used for treatment of heart failure on an empiric basis for ~200 years. The subsequent documentation of their lack of clinical efficacy...

  1. Performance Prediction of Mechanical Pump in STELLA-1

    Energy Technology Data Exchange (ETDEWEB)

    Han, Ji-Woong; Cho, Chungho; Jeong, Ji-Young [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    Under a mid- and long-term nuclear R-D program, STELLA (Sodium Integral Effect Test Loop for Safety Simulation and Assessment) project is in progress in KAERI (Korea Atomic Energy Research Institute). In STELLA-1, the experiments for the evaluation of heat exchangers such as DHX (Decay heat exchanger) and AHX (Air heat exchanger) are being performed, and those for PHTS (Primary heat transport system) mechanical pump are being prepared. The detailed design of each component is based on that of a 600MWe demonstration reactor. The model pump installed in STELLA-1 was scaled down based on the scaling law. Since the reference reactor of STELLA-1 is a 600MWe pool type demonstration reactor, some design modifications were inevitable between pool type prototype pump and loop type model pump, such as outer case and inlet pipe. In this study performance evaluation on the model pump has been done by CFD methods. The Design modeler in ANSYS Workbench was utilized in modeling process. The computations were performed using the commercial code ANSYS CFX. The overall hydraulic behaviors in the model pump have been predicted at a steady state condition.

  2. Impact of pulmonary hypertension on cardiac surgery.

    Directory of Open Access Journals (Sweden)

    G. Tinică

    2012-08-01

    Full Text Available BACKGROUND: Pulmonary hypertension (PH is a frequent condition in patients with congenital heart diseases and left ventricle diseases. Preoperative PH causes higher mortality rate after heart surgery and adverse cardiac events. METHODS: We performed a prospective study which included 159 patients with preoperative PH that had undergone cardiac surgery between November 2008 and November 2011 in the Institute of Cardiovascular Diseases of Iaşi. 28 patients had class 1.4.4 pulmonary artery hypertension (due to congenital cardiac shunts and 131 patients had class 2 PH (due to left heart diseases. The preoperative echocardiography included: assessment of the left ventricular volume and ejection fraction, systolic pressure in the pulmonary artery; right ventricular end-diastolic diameter; right atrium area indexed for body surface area; pulmonary acceleration/ejection time ratio; TAPSE; determination of the severity of the associated tricuspid regurgitation; pericardial fluid presence. The primary endpoint was perioperative mortality; the secondary endpoints included: pericardial, pleural, hepatic or renal complications; the need for a new surgical procedure; postoperative mechanical ventilation > 24 hours; intensive care unit length of stay; postoperative inotropic support duration; the need for intra-aortic balloon pump; the need for pulmonary vasodilator drugs. RESULTS: The mortality rate was 2.51% and was statistically associated with NYHA IV preoperative class, the pulmonary acceleration/ejection time ratio, TAPSE, the presence of pericardial fluid, the indexed area of the right atrium and the concomitant CABG. Severe pulmonary hypertension(sPAP > 60 mmHg is associated with significant mortality rate increase, longer hospitalization in the intensive care unit, mechanical ventilation over 24 hours, lengthy inotropic support and renal, hepatic and pericardial complications. Residual PH and perioperative right ventricle dysfunction are common

  3. Fluid pumping apparatus

    Science.gov (United States)

    West, Phillip B.

    2006-01-17

    A method and apparatus suitable for coupling seismic or other downhole sensors to a borehole wall in high temperature and pressure environments. In one embodiment, one or more metal bellows mounted to a sensor module are inflated to clamp the sensor module within the borehole and couple an associated seismic sensor to a borehole wall. Once the sensing operation is complete, the bellows are deflated and the sensor module is unclamped by deflation of the metal bellows. In a further embodiment, a magnetic drive pump in a pump module is used to supply fluid pressure for inflating the metal bellows using borehole fluid or fluid from a reservoir. The pump includes a magnetic drive motor configured with a rotor assembly to be exposed to borehole fluid pressure including a rotatable armature for driving an impeller and an associated coil under control of electronics isolated from borehole pressure.

  4. Melting of sodium clusters

    CERN Document Server

    Reyes-Nava, J A; Beltran, M R; Michaelian, K

    2002-01-01

    Thermal stability properties and the melting-like transition of Na_n, n=13-147, clusters are studied through microcanonical molecular dynamics simulations. The metallic bonding in the sodium clusters is mimicked by a many-body Gupta potential based on the second moment approximation of a tight-binding Hamiltonian. The characteristics of the solid-to-liquid transition in the sodium clusters are analyzed by calculating physical quantities like caloric curves, heat capacities, and root-mean-square bond length fluctuations using simulation times of several nanoseconds. Distinct melting mechanisms are obtained for the sodium clusters in the size range investigated. The calculated melting temperatures show an irregular variation with the cluster size, in qualitative agreement with recent experimental results. However, the calculated melting point for the Na_55 cluster is about 40 % lower than the experimental value.

  5. Cardiac fusion and complex congenital cardiac defects in thoracopagus twins: diagnostic value of cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of); Park, Jeong-Jun [University of Ulsan College of Medicine, Asan Medical Center, Department of Pediatric Cardiac Surgery, Seoul (Korea, Republic of); Kim, Ellen Ai-Rhan [University of Ulsan College of Medicine, Asan Medical Center, Division of Neonatology, Department of Pediatrics, Seoul (Korea, Republic of); Won, Hye-Sung [University of Ulsan College of Medicine, Asan Medical Center, Department of Obstetrics and Gynecology, Seoul (Korea, Republic of)

    2014-09-15

    Most thoracopagus twins present with cardiac fusion and associated congenital cardiac defects, and assessment of this anatomy is of critical importance in determining patient care and outcome. Cardiac CT with electrocardiographic triggering provides an accurate and quick morphological assessment of both intracardiac and extracardiac structures in newborns, making it the best imaging modality to assess thoracopagus twins during the neonatal period. In this case report, we highlight the diagnostic value of cardiac CT in thoracopagus twins with an interatrial channel and complex congenital cardiac defects. (orig.)

  6. Air-Operated Sump Pump

    Science.gov (United States)

    Nolt, Gary D.

    1988-01-01

    Pump removes liquid seepage from small, restricted area and against large pressure head. Developed for moving small amounts of water and oil from sump pit 85 ft (25.91 m) deep. Fits in space only 6 1/2 in. (16.5 cm) in diameter and 18 in. (45.7 cm) long. In discharge part of pumping cycle, air forces liquid out of pump chamber through pipe. During filling part of pumping cycle, water enters pump chamber from sump pit. Float in chamber next to pump chamber controls pressurization through timer and solenoid valve.

  7. Noise through Quantum Pumps

    OpenAIRE

    Polianski, M. L.; Vavilov, M. G.; Brouwer, P.W.

    2002-01-01

    We study the current noise through an unbiased quantum electron pump and its mesoscopic fluctuations for arbitrary temperatures and beyond the bilinear response. In the bilinear regime, we find the full distributions of the noise power and the current-to-noise ratio for a chaotic quantum dots with single-channel and many-channel ballistic point contacts. For a dot with many-channel point contacts we also calculate the ensemble-averaged noise at arbitrary temperature and pumping strength. In t...

  8. Reactor coolant pump flywheel

    Science.gov (United States)

    Finegan, John Raymond; Kreke, Francis Joseph; Casamassa, John Joseph

    2013-11-26

    A flywheel for a pump, and in particular a flywheel having a number of high density segments for use in a nuclear reactor coolant pump. The flywheel includes an inner member and an outer member. A number of high density segments are provided between the inner and outer members. The high density segments may be formed from a tungsten based alloy. A preselected gap is provided between each of the number of high density segments. The gap accommodates thermal expansion of each of the number of segments and resists the hoop stress effect/keystoning of the segments.

  9. Heat pump planning handbook

    CERN Document Server

    Bonin, Jürgen

    2015-01-01

    The Heat Pump Planning Handbook contains practical information and guidance on the design, planning and selection of heat pump systems, allowing engineers, designers, architects and construction specialists to compare a number of different systems and options. Including detailed descriptions of components and their functions and reflecting the current state of technology this guide contains sample tasks and solutions as well as new model calculations and planning evaluations. Also economic factors and alternative energy sources are covered, which are essential at a time of rising heat costs. T

  10. Regenerative adsorbent heat pump

    Science.gov (United States)

    Jones, Jack A. (Inventor)

    1991-01-01

    A regenerative adsorbent heat pump process and system is provided which can regenerate a high percentage of the sensible heat of the system and at least a portion of the heat of adsorption. A series of at least four compressors containing an adsorbent is provided. A large amount of heat is transferred from compressor to compressor so that heat is regenerated. The process and system are useful for air conditioning rooms, providing room heat in the winter or for hot water heating throughout the year, and, in general, for pumping heat from a lower temperature to a higher temperature.

  11. Radiative and rovibrational collisional relaxation of sodium dimer

    Science.gov (United States)

    Bayram, Burcin; Horton, Tim; McFarland, Jacob

    2016-05-01

    Radiative and rovibrational collisional relaxation of sodium dimer of the A1Σu+ (8,30) state have been measured by direct observation of the decay fluorescence. Sodium molecular vapor is created in a heatpipe oven at 600 K and excited using a 6-ns pulsed dye laser pumped by a Nd:YAG, operating at 532 nm. The preliminary lifetime measurement was done by directly acquiring lifetime data through boxcar averager from the stored oscilloscope trace of the fluorescence. Analysis of the exponential decay of the fluorescence allows us to obtain the radiative lifetime. By introducing the argon buffer gas and varying the pressure of the heatpipe, a collisional cross section between excited sodium dimer and ground state argon atom collision can be extracted using Stern-Volmer relation.

  12. Too Much Sodium

    Centers for Disease Control (CDC) Podcasts

    2012-02-07

    This podcast is based on the February 2012 CDC Vital Signs report. Ninety percent of Americans age two and older eat too much sodium which can increase your risk for high blood pressure and often leads to heart disease and stroke, two leading causes of death in the US. Learn several small steps you can take to reduce the amount of sodium in your diet.  Created: 2/7/2012 by Centers for Disease Control and Prevention (CDC).   Date Released: 2/7/2012.

  13. Radioactive sodium waste treatment and conditioning. Review of main aspects

    International Nuclear Information System (INIS)

    This publication reviews the main aspects relating to the treatment and conditioning of radioactive sodium waste. This waste arises from the operation of liquid metal fast reactors (LMFRs). In this type of reactor, sodium (Na) or sodium-potassium alloys (NaK) are used as a low-effect neutron moderating coolant medium for extracting and transferring thermal energy from the core and they represent a significant technical and safety challenge during operation and decommissioning. This publication provides the reader with technologically oriented information on the present status of sodium waste management approaches and recent achievements related to treatment and conditioning, with the objective of facilitating planning and preparatory work for the decommissioning of LMFRs. This publication provides a comprehensive review of the hazards associated with sodium waste management. Given the large quantities of sodium waste arising during decommissioning or reactor refurbishment, as well as the challenges and varied techniques associated with removal of 100% of all sodium and NaK bulk quantities and residues during decommissioning, a hazards review and analysis is a critical component in planning the dismantling and waste management activities. Roughly half of this publication focuses on sodium waste generating, handling and treatment processes. This includes draining sodium and NaK from plant systems; in situ treatment of residual sodium; cutting techniques for pumps, valves, piping and other components; cleaning of components; potential reuse of sodium; and removal of selected radionuclides from sodium waste with the objective of reducing the waste classification or converting it to exempt waste. The focus is on proven techniques and technologies, and each discussed method includes a review of the associated principle or theory, practical applications, advantages and disadvantages, limitations, industry experience, and final waste products. A review is provided of final

  14. In vitro Doppler ultrasound investigation of turbulence intensity in pulsatile flow with simulated cardiac variability.

    Science.gov (United States)

    Thorne, Meghan L; Poepping, Tamie L; Nikolov, Hristo N; Rankin, Richard N; Steinman, David A; Holdsworth, David W

    2009-01-01

    An in vitro investigation of turbulence intensity (TI) associated with a severe carotid stenosis in the presence of physiological cardiac variability is described. The objective of this investigation was to determine if fluctuations due to turbulence could be quantified with conventional Doppler ultrasound (DUS) in the presence of normal physiological cycle-to-cycle cardiac variability. An anthropomorphic model of a 70% stenosed carotid bifurcation was used in combination with a programmable flow pump to generate pulsatile flow with a mean flow rate of 6 mL/s. Utilizing the pump, we studied normal, nonrepetitive cycle-to-cycle cardiac variability (+/-3.9%) in flow, as well as waveform shapes with standard deviations equal to 0, 2 and 3 times the normal variation. Eighty cardiac cycles of Doppler data were acquired at two regions within the model, representing either laminar or turbulent flow; each measurement was repeated six times. Turbulence intensity values were found to be 11 times higher (p laminar region, with a mean difference of 24 cm/s. Twenty cardiac cycles were required for confidence in TI values. In conclusion, these results indicate that it is possible to quantify TI in vitro, even in the presence of normal and exaggerated cycle-to-cycle cardiac variability.

  15. Predicting the risk of sudden cardiac death.

    Science.gov (United States)

    Lerma, Claudia; Glass, Leon

    2016-05-01

    Sudden cardiac death (SCD) is the result of a change of cardiac activity from normal (typically sinus) rhythm to a rhythm that does not pump adequate blood to the brain. The most common rhythms leading to SCD are ventricular tachycardia (VT) or ventricular fibrillation (VF). These result from an accelerated ventricular pacemaker or ventricular reentrant waves. Despite significant efforts to develop accurate predictors for the risk of SCD, current methods for risk stratification still need to be improved. In this article we briefly review current approaches to risk stratification. Then we discuss the mathematical basis for dynamical transitions (called bifurcations) that may lead to VT and VF. One mechanism for transition to VT or VF involves a perturbation by a premature ventricular complex (PVC) during sinus rhythm. We describe the main mechanisms of PVCs (reentry, independent pacemakers and abnormal depolarizations). An emerging approach to risk stratification for SCD involves the development of individualized dynamical models of a patient based on measured anatomy and physiology. Careful analysis and modelling of dynamics of ventricular arrhythmia on an individual basis will be essential in order to improve risk stratification for SCD and to lay a foundation for personalized (precision) medicine in cardiology. PMID:26660287

  16. Aquaflo pump vs FMS 4 pump for shoulder arthroscopic surgery.

    OpenAIRE

    Ampat, G.; Bruguera, J.; Copeland, S A

    1997-01-01

    A prospective controlled trial was carried out to compare two different fluid delivery systems used for shoulder arthroscopy. One an advanced pump system that controls both pressure and flow of fluid delivered, the other an air-driven diaphragm pump that only controls fluid pressure. Blood loss, presence of bleeding vessels and visual clarity were parameters used to assess the pump systems. There was no difference between the pumps in straightforward shoulder procedures. However, complicated ...

  17. Sudden Cardiac Death

    Directory of Open Access Journals (Sweden)

    Yipsy María Gutiérrez Báez

    2015-09-01

    Full Text Available Since the second half of the twentieth century, dying suddenly due to heart-related problems has become the main health issue in all countries where infectious diseases are not prevalent. Sudden death from cardiac causes is an important global health problem. Major databases were searched for the leading causes of sudden cardiac death. It has been demonstrated that there is a group of hereditary diseases with structural alterations or without apparent organic cause that explains many cases of sudden death in young people, whether related or not to physical exertion. Certain population groups are at higher risk for this disease. They are relatively easy to identify and can be the target of primary prevention measures.

  18. Inherited cardiac disease

    Directory of Open Access Journals (Sweden)

    Philippe Charron

    2012-06-01

    Full Text Available Major advances have been achieved over the two last decades in the field of genetic cardiovascular diseases, not only through increased recognition and understanding of underlying molecular defects but also through rapid translation of knowledge into clinical practice. Genetic counseling and organization of cardiac family screening has become part of the medical management of these diseases, and these should be performed systematically unless an acquired cause has been diagnosed...

  19. Cardiac Tissue Engineering

    OpenAIRE

    MILICA RADISIC; GORDANA VUNJAK-NOVAKOVIC

    2009-01-01

    We hypothesized that clinically sized (1-5 mm thick),compact cardiac constructs containing physiologically high density of viable cells (~108 cells/cm3) can be engineered in vitro by using biomimetic culture systems capable of providing oxygen transport and electrical stimulation, designed to mimic those in native heart. This hypothesis was tested by culturing rat heart cells on polymer scaffolds, either with perfusion of culture medium (physiologic interstitial velocity, supplementation of p...

  20. Cardiac developmental toxicity

    OpenAIRE

    Mahler, Gretchen J.; Jonathan T Butcher

    2011-01-01

    Congenital heart disease is a highly prevalent problem with mostly unknown origins. Many cases of CHD likely involve an environmental exposure coupled with genetic susceptibility, but practical and ethical considerations make nongenetic causes of CHD difficult to assess in humans. The development of the heart is highly conserved across all vertebrate species, making animal models an excellent option for screening potential cardiac teratogens. This review will discuss exposures known to cause ...

  1. Is the human left ventricle partially a fractal pump?

    Science.gov (United States)

    Moore, Brandon; Dasi, Lakshmi

    2011-11-01

    Ventricular systolic and diastolic dysfunctions represent a large portion of healthcare problems in the United States. Many of these problems are caused and/or characterized by their altered fluid-structure mechanics. The structure of the left ventricle in particular is complex with time dependent multi-scale geometric complexity. At relatively small scales, one facet that is still not well understood is the role of trabeculae in the pumping function of the left ventricle. We utilize fractal geometry tools to help characterize the complexity of the inner surface of the left ventricle at different times during the cardiac cycle. A high-resolution three dimensional model of the time dependent ventricular geometry was constructed from computed tomography (CT) images in a human. The scale dependent fractal dimension of the ventricle was determined using the box-counting algorithm over the cardiac cycle. It is shown that the trabeculae may indeed play an integral role in the biomechanics of pumping by regulating the mechanical leverage available to the cardiac muscle fibers.

  2. Piston for rod pumping

    Energy Technology Data Exchange (ETDEWEB)

    Pastushenko, G.I.

    1965-06-22

    A piston, or plunger, for rod pumping, is made up of a cylindrical housing with labryinthal seals, a nose piece, and a scraper. In order to remove paraffin from the inside surface of the production pipe, the housing is made in telescopic form. The scraper consists of an arrangement of springs installed on the outer surface of the housing.

  3. Pump Flow Analysis

    Science.gov (United States)

    1981-01-01

    Ingersoll-Rand Research, Inc.'s use of COSMIC's computer program MERIDL permits designers to evaluate performance and efficiency characteristics to be expected from the pump's impeller. It also provides information that enables a trained hydraulic engineer to make design improvements. Company was able to avoid the cost of developing new software and to improve some product design features.

  4. Microfluidic "blinking" bubble pump

    NARCIS (Netherlands)

    Yin, Zhizhong; Prosperetti, Andrea

    2005-01-01

    The paper reports data obtained on a simple micropump, suitable for electrolytes, based on the periodic growth and collapse of a single vapor bubble in a microchannel. With a channel diameter of the order of 100 µm, pumping rates of several tens of µl/min and pressure differences of several kPa are

  5. Cardiac hybrid imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gaemperli, Oliver [University Hospital Zurich, Cardiac Imaging, Zurich (Switzerland); University Hospital Zurich, Nuclear Cardiology, Cardiovascular Center, Zurich (Switzerland); Kaufmann, Philipp A. [University Hospital Zurich, Cardiac Imaging, Zurich (Switzerland); Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland)

    2014-05-15

    Hybrid cardiac single photon emission computed tomography (SPECT)/CT imaging allows combined assessment of anatomical and functional aspects of cardiac disease. In coronary artery disease (CAD), hybrid SPECT/CT imaging allows detection of coronary artery stenosis and myocardial perfusion abnormalities. The clinical value of hybrid imaging has been documented in several subsets of patients. In selected groups of patients, hybrid imaging improves the diagnostic accuracy to detect CAD compared to the single imaging techniques. Additionally, this approach facilitates functional interrogation of coronary stenoses and guidance with regard to revascularization procedures. Moreover, the anatomical information obtained from CT coronary angiography or coronary artery calcium scores (CACS) adds prognostic information over perfusion data from SPECT. The use of cardiac hybrid imaging has been favoured by the dissemination of dedicated hybrid systems and the release of dedicated image fusion software, which allow simple patient throughput for hybrid SPECT/CT studies. Further technological improvements such as more efficient detector technology to allow for low-radiation protocols, ultra-fast image acquisition and improved low-noise image reconstruction algorithms will be instrumental to further promote hybrid SPECT/CT in research and clinical practice. (orig.)

  6. Optimization of compound gear pump

    Institute of Scientific and Technical Information of China (English)

    栾振辉

    2002-01-01

    This paper introduces the performances of compound gear pump. Based on the target of having the smallest mass per unit volume, the paper established a mathematical model of optimization, and obtained the results of optimization of the pump.

  7. Orbital Liquid Oxygen Pump Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposed work will develop a pump, which is based on two novel and unique design features. The first feature is a lobed pumping mechanism which operates with...

  8. Fuel Pumping System And Method

    Science.gov (United States)

    Shafer, Scott F.; Wang, Lifeng

    2005-12-13

    A fuel pumping system that includes a pump drive is provided. A first pumping element is operatively connected to the pump drive and is operable to generate a first flow of pressurized fuel. A second pumping element is operatively connected to the pump drive and is operable to generate a second flow of pressurized fuel. A first solenoid is operatively connected to the first pumping element and is operable to vary at least one of a fuel pressure and a fuel flow rate of the first flow of pressurized fuel. A second solenoid is operatively connected to the second pumping element and is operable to vary at least one of a fuel pressure and a fuel flow rate of the second flow of pressurized fuel.

  9. Sodium fluxes in sweet pepper exposed to varying sodium concentrations

    NARCIS (Netherlands)

    Blom-Zandstra, M.; Vogelzang, S.A.; Veen, B.W.

    1998-01-01

    The sodium transport and distribution of sweet pepper (Capsicum annuum L.) under saline conditions were studied after transferring the plants to a sodium-free nutrient solution. Sodium stress up to 60 mM did not affect the growth of sweet pepper, as it appears able to counteract the unfavourable phy

  10. Inhibition of collagen synthesis by select calcium and sodium channel blockers can be mitigated by ascorbic acid and ascorbyl palmitate

    OpenAIRE

    Ivanov, Vadim; Ivanova, Svetlana; KALINOVSKY, TATIANA; NIEDZWIECKI, ALEKSANDRA; RATH, MATTHIAS

    2016-01-01

    Calcium, sodium and potassium channel blockers are widely prescribed medications for a variety of health problems, most frequently for cardiac arrhythmias, hypertension, angina pectoris and other disorders. However, chronic application of channel blockers is associated with numerous side effects, including worsening cardiac pathology. For example, nifedipine, a calcium-channel blocker was found to be associated with increased mortality and increased risk for myocardial infarction. In addition...

  11. Blood Pump Bearing System

    Science.gov (United States)

    Aber, Gregory S. (Inventor)

    2000-01-01

    An apparatus is provided for a blood pump bearing system within a pump housing to support long-term highspeed rotation of a rotor with an impeller blade having a plurality of individual magnets disposed thereon to provide a small radial air gap between the magnets and a stator of less than 0.025 inches. The bearing system may be mounted within a flow straightener, diffuser, or other pump element to support the shaft of a pump rotor. The bearing system includes a zirconia shaft having a radiused end. The radiused end has a first radius selected to be about three times greater than the radius of the zirconia shaft. The radiused end of the zirconia shaft engages a flat sapphire endstone. Due to the relative hardness of these materials a flat is quickly produced during break-in on the zirconia radiused end of precisely the size necessary to support thrust loads whereupon wear substantially ceases. Due to the selection of the first radius, the change in shaft end-play during pump break-in is limited to a total desired end-play of less than about 0.010 inches. Radial loads are supported by an olive hole ring jewel that makes near line contact around the circumference of the Ir shaft to support big speed rotation with little friction. The width of olive hole ring jewel is small to allow heat to conduct through to thereby prevent heat build-up in the bearing. A void defined by the bearing elements may fill with blood that then coagulates within the void. The coagulated blood is then conformed to the shape of the bearing surfaces.

  12. Absorption heat pumps

    Science.gov (United States)

    Huhtinen, M.; Heikkilae, M.; Andersson, R.

    1987-03-01

    The aim of the study was to analyze the technical and economic feasibility of absorption heat pumps in Finland. The work was done as a case study: the technical and economic analyses have been carried out for six different cases, where in each the suitable size and type of the heat pump plant and the auxiliary components and connections were specified. The study also detailed the costs concerning the procurement, installation and test runs of the machinery, as well as the savings in energy costs incurred by the introduction of the plant. Conclusions were drawn of the economic viability of the applications studied. The following cases were analyzed: heat recovery from flue gases and productin of district heat in plants using peat, natural gas, and municipal wastes as a fuel. Heat recovery in the pulp and paper industry for the upgrading of pressure of secondary steam and for the heating of white liquor and combustion and drying the air. Heat recovery in a peat-fulled heat and power plant from flue gases that have been used for the drying of peat. According to the study, the absorption heat pump suits best to the production of district heat, when the heat source is the primary energy is steam produced by the boiler. Included in the flue as condensing is the purification of flue gases. Accordingly, benefit is gained on two levels in thick applications. In heat and power plants the use of absorption heat pumps is less economical, due to the fact that the steam used by the pump reduces the production of electricity, which is rated clearly higher than heat.

  13. Design of a Mechanical NaK Pump for Fission Space Power Systems

    Science.gov (United States)

    Mireles, Omar R.; Bradley, David; Godfroy, Thomas

    2010-01-01

    Alkali liquid metal cooled fission reactor concepts are under development for mid-range spaceflight power requirements. One such concept utilizes a sodium-potassium eutectic (NaK) as the primary loop working fluid. Traditionally, linear induction pumps have been used to provide the required flow and head conditions for liquid metal systems but can be limited in performance. This paper details the design, build, and check-out test of a mechanical NaK pump. The pump was designed to meet reactor cooling requirements using commercially available components modified for high temperature NaK service.

  14. Conceptual design of advanced central receiver power systems sodium-cooled receiver concept. Volume 2, Book 1. Commercial plant conceptual design. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1979-03-01

    The conceptual design of the 100-MW solar tower focus commercial power plant is described in detail. Sodium is pumped up to the top of a tall tower where the receiver is located. The sodium is heated in the receiver and then flows down the tower, through a pressure reducing device, and thence into a large, hot storage tank which is located at ground level and whose size is made to meet a specific thermal energy storage capacity requirement. From this tank, the sodium is pumped by a separate pump, through a system of sodium-to-water steam generators. The steam generator system consists of a separate superheater and reheater operating in parallel and an evaporator unit operating in series with the other two units. The sodium flowing from the evaporator unit is piped to a cold storage tank. From the cold storage tank, sodium is then pumped up to the tip of the tower to complete the cycle. The steam generated in the steam generators is fed to a conventional off-the-shelf, high-efficiency turbine. The steam loop operates in a conventional rankine cycle with the steam generators serving the same purpose as a conventional boiler and water being fed to the evaporator with conventional feedwater pumps. The pressure reducing device (a standard drag valve, for example) serves to mitigate the pressure caused by the static head of sodium and thus allows the large tanks to operate at ambient pressure conditions. (WHK)

  15. Indeterminacy of Spatiotemporal Cardiac Alternans

    CERN Document Server

    Zhao, Xiaopeng

    2007-01-01

    Cardiac alternans, a beat-to-beat alternation in action potential duration (at the cellular level) or in ECG morphology (at the whole heart level), is a marker of ventricular fibrillation, a fatal heart rhythm that kills hundreds of thousands of people in the US each year. Investigating cardiac alternans may lead to a better understanding of the mechanisms of cardiac arrhythmias and eventually better algorithms for the prediction and prevention of such dreadful diseases. In paced cardiac tissue, alternans develops under increasingly shorter pacing period. Existing experimental and theoretical studies adopt the assumption that alternans in homogeneous cardiac tissue is exclusively determined by the pacing period. In contrast, we find that, when calcium-driven alternans develops in cardiac fibers, it may take different spatiotemporal patterns depending on the pacing history. Because there coexist multiple alternans solutions for a given pacing period, the alternans pattern on a fiber becomes unpredictable. Usin...

  16. An overview of cardiac morphogenesis.

    Science.gov (United States)

    Schleich, Jean-Marc; Abdulla, Tariq; Summers, Ron; Houyel, Lucile

    2013-11-01

    Accurate knowledge of normal cardiac development is essential for properly understanding the morphogenesis of congenital cardiac malformations that represent the most common congenital anomaly in newborns. The heart is the first organ to function during embryonic development and is fully formed at 8 weeks of gestation. Recent studies stemming from molecular genetics have allowed specification of the role of cellular precursors in the field of heart development. In this article we review the different steps of heart development, focusing on the processes of alignment and septation. We also show, as often as possible, the links between abnormalities of cardiac development and the main congenital heart defects. The development of animal models has permitted the unraveling of many mechanisms that potentially lead to cardiac malformations. A next step towards a better knowledge of cardiac development could be multiscale cardiac modelling. PMID:24138816

  17. VIRTUAL FUEL-PUMP DESIGN

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Some concepts of virtual product are discussed. The key technologies of virtual fuel-pump development are in detail analysed, which include virtual fuel-pump product modeling, intelligent simulation, distributed design environment, and virtual assembly. The virtual fuel-pump development prototype system considers requirement analysis, concept design, injection preferment analysis, detailed design, and assembly analysis.

  18. Small Scroll Pump for Cryogenic Liquids Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The innovation is a compact, reliable, light weight, electrically driven pump capable of pumping cryogenic liquids, based on scroll pump technology. This pump will...

  19. Improving pumping system efficiency at coal plants

    Energy Technology Data Exchange (ETDEWEB)

    Livoti, W.C.; McCandless, S.; Poltorak, R. [Baldor Electric Co. (United States)

    2009-03-15

    The industry must employ ultramodern technologies when building or upgrading power plant pumping systems thereby using fuels more efficiently. The article discusses the uses and efficiencies of positive displacement pumps, centrifugal pumps and multiple screw pumps. 1 ref., 4 figs.

  20. Sudden Cardiac Death in Athletes.

    Science.gov (United States)

    Wasfy, Meagan M; Hutter, Adolph M; Weiner, Rory B

    2016-01-01

    There are clear health benefits to exercise; even so, patients with cardiac conditions who engage in exercise and athletic competition may on rare occasion experience sudden cardiac death (SCD). This article reviews the epidemiology and common causes of SCD in specific athlete populations. There is ongoing debate about the optimal mechanism for SCD prevention, specifically regarding the inclusion of the ECG and/or cardiac imaging in routine preparticipation sports evaluation. This controversy and contemporary screening recommendations are also reviewed. PMID:27486488

  1. A Numerical Modeling of A Vascular Implantable Cardiac Endovascular Assistant (AVICENA)

    Science.gov (United States)

    Rahmani, Shahrokh; Tehrani, Pedram; Karimi, Alireza; Alizadeh, Mansour; Navidbakhsh, Mahdi

    2015-10-01

    Cardiovascular diseases have been recently shown to have a pivotal role in human death and endangers lives of many people around the world. One of the most common cardiovascular diseases is poor performance of left ventricle. In this case, the ventricle cannot pump the blood into the aorta and circulatory system with a suitable power which is required for normal circulatory system. AVICENA is a new cardiac assist device which is implanted into the aorta to help the ventricle to pump the blood into circulatory system with more power and to make a better perfusion of the coronary arteries as well. To reach a desire value of rotational speed of the pump, a control circuit is designed for counterpulsation of AVICENA based on the outcomes from previous studies. This control circuit uses a PID controller. The present study aims to simulate the blood flow through the balloon part of AVICENA in a heart cycle with focusing on the calculation of its pump rotational speed by controlling the electrical current of the pump. Results revealed that the desired rotational speed of the pump can be achieved according to the previous aorta pressure cycle by electrical current control which is higher during balloon inflation in comparison with balloon deflation. These findings may have implications not only for understanding the performance of AVICENA but also to help cardiac mechanics experts to improve the shortcoming of this newborn device.

  2. Slicing sodium from bakery products

    NARCIS (Netherlands)

    Noort, M.

    2012-01-01

    The need for sodium reduction in our diet is clear to consumers, dieticians and food manufacturers. As sodium concentration has a strengthening effect on gluten, sodium reduction decreases dough mixing tolerance, dough resistance and induces dough stickiness. In particular, the latter may cause prob

  3. Pumping characteristics of roots blower pumps for light element gases

    International Nuclear Information System (INIS)

    The pumping speed and compression ratio of the two-stage roots blower pumping system were measured for light element gases (H2, D2 and He) and for N2, in order to assess validity of the ITER torus roughing system as an ITER R and D task (T234). The pumping system of an Edwards EH1200 (nominal pumping speed of 1200 m3/s), two EH250s (ibid. 250 m3/s) and a backing pump (ibid. 100 m3/s) in series connection was tested under PNEUROP standards. The maximum pumping speeds of the two-stage system for D2 and N2 were 1200 and 1300 m3/h, respectively at 60 Hz, which satisfied the nominal pumping speed. These experimental data support the design validity of the ITER torus roughing system. (author)

  4. Development of an annular linear induction electromagnetic pump for the na-coolant circulation of LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hee Reyoung; Lee, Yong Bum; Kim, Yong Kyun; Nam, Ho Yun [KAERI, Taejon (Korea, Republic of)

    1998-07-01

    The EM (ElectroMagnetic) pump operated by Lorentz force (J x B) is developed for the sodium coolant circulation of LMFBR (Liquid Metal Fast Breeder Reactors). Design and experimental characterization are carried out on the linear induction EM pump of the narrow annular channel type. The pump which obtains propulsion force resultantly by the three phase symmetric alternating input currents is analyzed by the electrical equivalent circuit method used in the analyses of the induction machines. Then, the equivalent circuit for the pump consists of equivalent variables of primary and secondary resistances and magnetizing and leakage reactances given as functions of pump geometrical and electrical variables by Laithwaithe's standard formulae. Developing pressure-flowrate relation given by pump variables is sought from the balance equation on the circuit. Developing pressure and efficiency of the pump according to the pump variables are analyzed for the pump with a flowrate of 200 l/min. It is shown that pump is mainly characterized by length of the core, diameter of the inner core and channel gap geometrically and by input frequency electrically. Optimum values of pump geometrical and operational variables are determined to maximize the developing force and overall efficiency. The pump has geometrical size of 60 cm in length, 4.27 cm in inner core diameter and electrical input of 6,428 VA and 17 Hz. Optimally designed pump is manufactured by the consideration of material and operational requirements in the chemically-active sodium environment with high temperature of 600 .deg. C. Silicon-iron steel plates with high magnetic permeability in the high temperature are stacked for generation of the high magnetic flux and alumina-dispersion-strengthened-copper bands are used as exciting coils. Each turn of coil is insulated by asbestos band to protect electrical short in the high temperature. Stainless steel which can be compatible with sodium is selected as structural

  5. Case Report: Penetrating Cardiac Injury

    Directory of Open Access Journals (Sweden)

    Adem Grbolar

    2013-10-01

    Full Text Available Summary: Penetrating cardiac injurys caused by gunshots and penetrating tools have high mortality rates. The way of injury, how the cardiac area is effected and the presence of cardiac tamponadecauses mortality in different rates. However the better treatment quality of hospitals, increasingoperative techniques, and internel care unit quality has not been change during the years. Searching the literature, we want to present a 42 years old male patient whowas injured by knife and had a 1 cm skin wound on chest with cardiac tamponade. After sternotomy a 7 cm laseration was observed in heart. Cardioraphy was performed.

  6. French sodium waste storage rules

    International Nuclear Information System (INIS)

    In the frame of Superphenix Plant decommissioning, CEA and EDF had to determine the rules to applied for safe sodium waste storage. Even if sodium waste storage has been monitored for some decades (but only during Operational Plant phases), some recent events showed that this item had to be secured before beginning large decommissioning operations. Of course, the best way would be an on-line treatment but operational constraints always imply a delay in this operation. Indeed, a number of sodium wastes will be produced during the period before the end of Superphenix sodium treatment (planned in 2013) and will have to wait for further treatment. The events to be avoided, or at least taken into account, are uncontrolled sodium reaction with air moisture (large hydrogen production, important overheating) and sodium reaction with liquid water (pressure waves, large hydrogen production, important overheating). Careful analysis of all abnormal events in sodium waste storage disposal was performed and led to rule evolution. In 2004, experimental studies were undertaken, in order to know how solid sodium at room temperature reacts with air humidity: the conditions of aqueous sodium hydroxide production (which is the main risk source in sodium waste storage) have been observed. On this basis, new general safe rules for sodium waste storage have been raised: - Waste classifying: pure sodium and soda to be separated, bulk and residues to be separated - Sodium waste containers: tight, dry, easy to refill with gas, protected against overpressure effect, with specific marking and reference - Dedicated rooms: dry, with specific markings, with specific sodium fire extinguishers - Maximum duration: three months before next refill with inert dry gas, in an over-container if more than one year - Dry gas feeling: inert gas except for sodium film residues (dry air) 395 For Superphenix application, packaging and storage conditions of sodium wastes have been defined, in accordance with

  7. Sodium source development for pulsed power driven, photopumped NA/NE x-ray laser experiments

    International Nuclear Information System (INIS)

    A sodium plasma source is being developed for a resonant photopumping x-ray laser scheme in which the 11A 1s2 - 1s2rho 1P1 line in heliumlike Na X is used to pump the Ne IX n=4 singlet level. In their experiment the NRL Gamble II generator is used to produce two z-pinch plasmas in a side-by-side geometry. The sodium plasma is produced on axis and conducts the full 1 MA machine current. A fraction of this current returns through a neon gas puff located 5 cm from the sodium. This separation is determined by the need to prevent the plasmas from mixing and the need to have each plasma's azimuthal magnetic field as symmetric as possible. A minimum separation is desirable to increase coupling efficiency. To improve the pump source, a more confined source of pure sodium involving a coaxial plasma gun is being developed. They are currently studying both the operation of this source on a test stand and implosions of the resulting plasma on Gamble II. In initial experiments aluminum is substituted for sodium. Test stand diagnostics include photodiodes, witness plates, and current monitors designed to investigate the early motion of the annular plasma. Results from test stand and Gamble II experiments with both aluminum and sodium, as well as sodium handling techniques, are presented

  8. SHINE Vacuum Pump Test Verification

    Energy Technology Data Exchange (ETDEWEB)

    Morgan, Gregg A; Peters, Brent

    2013-09-30

    Normetex pumps used world-wide for tritium service are no longer available. DOE and other researchers worldwide have spent significant funds characterizing this pump. Identification of alternate pumps is required for performance and compatibility with tritium gas. Many of the pumps that could be used to meet the functional performance requirements (e.g. pressure and flow conditions) of the Normetex pump have features that include the use of polymers or oils and greases that are not directly compatible with tritium service. This study assembles a test system to determine the flow characteristics for candidate alternate pumps. These tests are critical to the movement of tritium through the SHINE Tritium Purification System (TPS). The purpose of the pump testing is two-fold: (1) obtain baseline vacuum pump characteristics for an alternate (i.e. ''Normetex replacement'') pump intended for use in tritium service; and (2) verify that low pressure hydrogen gas can be transported over distances up to 300 feet by the candidate pumps. Flow rates and nominal system pressures have been identified for the SHINE Mo-99 production process Tritium Purification System (TPS). To minimize the line sizes for the transfer of low pressure tritium from the Neutron Driver Accelerator System (NDAS) to the primary processing systems in the TPS, a ''booster'' pump has been located near the accelerator in the design. A series of pump tests were performed at various configurations using hydrogen gas (no tritium) to ensure that this concept is practical and maintains adequate flow rates and required pressures. This report summarizes the results of the tests that have been performed using various pump configurations. The current design of the Tritium Purification System requires the ''booster'' pump to discharge to or to be backed by another vacuum pump. Since Normetex pumps are no longer manufactured, a commercially available Edwards

  9. VIBRATION ANALYSIS IN OVERHUNG PUMP

    OpenAIRE

    Neelendra Pratap Singh*, Prateek Gupta, Siddharth Agnihotri

    2016-01-01

    In the present scenario, Energy demand is increasing day by day. To meet that demand, the production or extraction of crude oil, natural gas and other energy resources is done with the help of various pumps. Pumps are the second largest used machinery in world and plays a vital role. In this paper, we have done analysis on centrifugal pump categorised as overhung pump (OH2). It is commonly known that vibration problems on centrifugal pumps can result from multitude of possible parameters whic...

  10. THE FIRST DOMESTIC IMPLANTABLE AXIAL FLOW PUMP: RESULTS OF EXPERIMENTAL STUDIES IN CALVES

    Directory of Open Access Journals (Sweden)

    G. P. Itkin

    2013-01-01

    Full Text Available Aim of our experimental study was evaluation of the first domestic implantable axial pump as a left ventricle assist device in calves. Materials and methods. 18 calves 90–120 days of age, weighing 95 ± 5 kg were exposed to implantation of an axial pump under the scheme «left ventricular – aorta» in paracorporeal and implantable in chest cavity versions. Two models of the pump were tested. Model 1 is a pump with cylindrical bearings and elongated straightener, model 2 had ball bearings and modified design of impeller and straightener. Results. In the first series (n = 12 the pump model 1 was tested. The duration of experiments was 4,9 ± 5,3 days, maximal duration was 16 days. The experiments were finalized due to intraoperation cardiac fibrillation (n = 3, uncrop- ped acute bleeding (n = 3, lowering of blood flow through the pump of 60 ± 15% (n = 6 because of thrombo- sis of the pump (n = 5 and outlet line (n = 1, in 3 cases of 5, combined with mechanical wear of bearings. In the second series (n = 6 the pump model 2 was tested. In 4 experiments of 6 the duration was 74,5 ± 29 days. One experiment was finalized due to intraoperation cardiac fibrillation. Another one experiment was finalized on 8 day as planned. In 5 experiments there was absence of either thrombosis or mechanical wear of bearings. Morphological and histological examination of the kidneys, liver and lungs in the 5 experiments of second series did not reveal the presence of zones of ischemia or thromboembolia. Conclusion. The results of the second series can be treaded as preclinical testing of the first domestic implantable axial pump as a left ventricle assist device in calves. 

  11. Crystal structure of the plasma membrane proton pump.

    Science.gov (United States)

    Pedersen, Bjørn P; Buch-Pedersen, Morten J; Morth, J Preben; Palmgren, Michael G; Nissen, Poul

    2007-12-13

    A prerequisite for life is the ability to maintain electrochemical imbalances across biomembranes. In all eukaryotes the plasma membrane potential and secondary transport systems are energized by the activity of P-type ATPase membrane proteins: H+-ATPase (the proton pump) in plants and fungi, and Na+,K+-ATPase (the sodium-potassium pump) in animals. The name P-type derives from the fact that these proteins exploit a phosphorylated reaction cycle intermediate of ATP hydrolysis. The plasma membrane proton pumps belong to the type III P-type ATPase subfamily, whereas Na+,K+-ATPase and Ca2+-ATPase are type II. Electron microscopy has revealed the overall shape of proton pumps, however, an atomic structure has been lacking. Here we present the first structure of a P-type proton pump determined by X-ray crystallography. Ten transmembrane helices and three cytoplasmic domains define the functional unit of ATP-coupled proton transport across the plasma membrane, and the structure is locked in a functional state not previously observed in P-type ATPases. The transmembrane domain reveals a large cavity, which is likely to be filled with water, located near the middle of the membrane plane where it is lined by conserved hydrophilic and charged residues. Proton transport against a high membrane potential is readily explained by this structural arrangement. PMID:18075595

  12. Advanced heat pump cycle

    Energy Technology Data Exchange (ETDEWEB)

    Groll, E.A.; Radermacher, R.

    1993-07-01

    The desorption and absorption process of a vapor compression heat pump with a solution circuit (VCHSC) proceeds at gliding temperature intervals, which can be adjusted over a wide range. In case that the gliding temperature intervals in the desorber and the absorber overlap, a modification of the VCHSC employing a desorber/absorber heat exchange (DAHX) can be introduced, which results in an extreme reduction of the pressure ratio. Although the DAHX-cycle has features of a two-stage cycle, it still requires only one solution pump, one separator and one compressor. Such a cycle for the working pair ammonia/water is built in the Energy Laboratory of the Center for Environmental Energy Engineering at the University of Maryland. The experimental results obtained with the research plant are discussed and compared to those calculated with a simulation program. The possible temperature lift between heat source and heat sink depending on the achievable COP are presented.

  13. Solar-powered pump

    Science.gov (United States)

    Kirsten, C. C. (Inventor)

    1976-01-01

    A solar powered pump particularly suited for intermittently delivering a stream of water is reported. The pump is characterized by a housing adapted to be seated in a source of water having a water discharge port disposed above the water line of the source, a sump including a valved inlet port through which water is introduced to the sump, disposed beneath the water line, a displacer supported for vertical reciprocation in said housing, an air passageway extended between the vertically spaced faces of the displacer, and a tipple disposed adjacent to the water discharge port adapted to be filled in response to a discharge of water from the housing. Air above a displacer is expanded in response to solar energy impinging on the housing and transferred into pressurizing relation with the sump for forcing water from the sump.

  14. Water displacement mercury pump

    Science.gov (United States)

    Nielsen, Marshall G.

    1985-01-01

    A water displacement mercury pump has a fluid inlet conduit and diffuser, a valve, a pressure cannister, and a fluid outlet conduit. The valve has a valve head which seats in an opening in the cannister. The entire assembly is readily insertable into a process vessel which produces mercury as a product. As the mercury settles, it flows into the opening in the cannister displacing lighter material. When the valve is in a closed position, the pressure cannister is sealed except for the fluid inlet conduit and the fluid outlet conduit. Introduction of a lighter fluid into the cannister will act to displace a heavier fluid from the cannister via the fluid outlet conduit. The entire pump assembly penetrates only a top wall of the process vessel, and not the sides or the bottom wall of the process vessel. This insures a leak-proof environment and is especially suitable for processing of hazardous materials.

  15. Sucker rod pump

    Energy Technology Data Exchange (ETDEWEB)

    Brewer, J.R.

    1992-04-14

    This patent describes a subsurface well pump, it comprises: a working barrel; a plunger which reciprocates along the vertical axis within the working barrel between an upper and lower position; a rod connected to the plunger and extending to a means for providing reciprocating force; a well string extending from the top of the working barrel to the surface; an outlet check valve which permits flow to exit the working barrel into the well string and does not permit flow to exit the well string into the working barrel; and an inlet check valve which permits flow into the working barrel from outside of the subsurface pump, the inlet check valve being above the top position of the plunger, the inlet check valve having a cross sectional flow area about equal to or greater than the horizontal cross sectional area of the working barrel, and the inlet check valve being a hinged flapper valve.

  16. Pocket pumped image analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kotov, I.V., E-mail: kotov@bnl.gov [Brookhaven National Laboratory, Upton, NY 11973 (United States); O' Connor, P. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Murray, N. [Centre for Electronic Imaging, Open University, Milton Keynes, MK7 6AA (United Kingdom)

    2015-07-01

    The pocket pumping technique is used to detect small electron trap sites. These traps, if present, degrade CCD charge transfer efficiency. To reveal traps in the active area, a CCD is illuminated with a flat field and, before image is read out, accumulated charges are moved back and forth number of times in parallel direction. As charges are moved over a trap, an electron is removed from the original pocket and re-emitted in the following pocket. As process repeats one pocket gets depleted and the neighboring pocket gets excess of charges. As a result a “dipole” signal appears on the otherwise flat background level. The amplitude of the dipole signal depends on the trap pumping efficiency. This paper is focused on trap identification technique and particularly on new methods developed for this purpose. The sensor with bad segments was deliberately chosen for algorithms development and to demonstrate sensitivity and power of new methods in uncovering sensor defects.

  17. Specialists' meeting on sodium fires

    International Nuclear Information System (INIS)

    The four sessions of the meeting covered the following topics: 1. general approach to fast reactor safety, standards of fire safety, maximum design basis accidents for sodium leaks and fires, status of sodium fires in different countries; 2. physical and chemical processes during combustion of sodium and its interaction with structural and technological materials and methods for structural protection; 3. methods of sodium fires extinguishing and measures for localizing aerosol combustion products, organization of fire fighting procedures, instruction and training of fire personnel; 4. elimination of the consequences of sodium fires

  18. Antifibrinolytics in cardiac surgery

    Directory of Open Access Journals (Sweden)

    Achal Dhir

    2013-01-01

    Full Text Available Cardiac surgery exerts a significant strain on the blood bank services and is a model example in which a multi-modal blood-conservation strategy is recommended. Significant bleeding during cardiac surgery, enough to cause re-exploration and/or blood transfusion, increases morbidity and mortality. Hyper-fibrinolysis is one of the important contributors to increased bleeding. This knowledge has led to the use of anti-fibrinolytic agents especially in procedures performed under cardiopulmonary bypass. Nothing has been more controversial in recent times than the aprotinin controversy. Since the withdrawal of aprotinin from the world market, the choice of antifibrinolytic agents has been limited to lysine analogues either tranexamic acid (TA or epsilon amino caproic acid (EACA. While proponents of aprotinin still argue against its non-availability. Health Canada has approved its use, albeit under very strict regulations. Antifibrinolytic agents are not without side effects and act like double-edged swords, the stronger the anti-fibrinolytic activity, the more serious the side effects. Aprotinin is the strongest in reducing blood loss, blood transfusion, and possibly, return to the operating room after cardiac surgery. EACA is the least effective, while TA is somewhere in between. Additionally, aprotinin has been implicated in increased mortality and maximum side effects. TA has been shown to increase seizure activity, whereas, EACA seems to have the least side effects. Apparently, these agents do not differentiate between pathological and physiological fibrinolysis and prevent all forms of fibrinolysis leading to possible thrombotic side effects. It would seem prudent to select the right agent knowing its risk-benefit profile for a given patient, under the given circumstances.

  19. Nonazeotropic Heat Pump

    Science.gov (United States)

    Ealker, David H.; Deming, Glenn

    1991-01-01

    Heat pump collects heat from water circulating in heat-rejection loop, raises temperature of collected heat, and transfers collected heat to water in separate pipe. Includes sealed motor/compressor with cooling coils, evaporator, and condenser, all mounted in outer housing. Gradients of temperature in evaporator and condenser increase heat-transfer efficiency of vapor-compression cycle. Intended to recover relatively-low-temperature waste heat and use it to make hot water.

  20. Stirling Engine Heat Pump

    Science.gov (United States)

    Kagawa, Noboru

    Recent advances in the feasibility studies related to the Stirling engines and Stirling engine heat pumps which have been considered attractive due to their promising role in helping to solve the global environmental and energy problems,are reviewed. This article begins to describe the brief history of the Stirling engines and theoretical thermodynamic analysis of the Stirling cycle in order to understand several advantages on the Stirling engine. Furthermore,they could throw light on our question why the dream engines had not been promoted to practical applications during two hundred years. The present review shows that the Stirling engines with several unique advantages including 30 to 40% thermal efficiency and preferable exhaust characteristics,had been designed and constructed by recent tackling for the development of the advanced automobile and other applications using them. Based on the current state of art,it is being provided to push the Stirling engines combined with heat pumps based on the reversed Rankine cycle to the market. At present,however, many problems, especially for the durability, cost, and delicate engine parts must be enforced to solve. In addition,there are some possibilities which can increase the attractiveness of the Stirling engines and heat pumps. The review closes with suggestions for further research.

  1. Electrocentrifugal pumping; Bombeo electrocentrifugo

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Perez, Guillermo; Medellin Otero, Hector [Instituto Mexicano del Peroleo (Mexico)

    1996-07-01

    The exploitation of isolated oil deposits, in losing their own energy, enter a phase of secondary recovery. One of the technologies of new development in Mexico is the one of electrocentrifugal pumping , which consists of introducing the motor-pump as an integral part of the production pipe down to the well bottom and pumping directly up to central complexes, from where it is sent inland. In the present paper is intended to explain what this type of secondary recovery consists of. [Spanish] La explotacion de yacimientos aislados de petroleo, al perder su energia propia, entran en una fase de recuperacion secundaria. Una de las tecnologias de nuevo desarrollo en Mexico es la de bombeo electrocentrifugo, la cual consiste en introducir la motobomba como parte integral de la tuberia de produccion hasta el fondo del pozo y bombearlo directamente hasta los complejos centrales, de donde se envia a tierra. En el presente trabajo se pretende explicar en que consiste este tipo de recuperacion secundaria.

  2. Pumping potential wells

    Science.gov (United States)

    Hershkowitz, N.; Forest, C.; Wang, E. Y.; Intrator, T.

    1987-01-01

    Nonmonotonic plasma potential structures are a common feature of many double layers and sheaths. Steady state plasma potential wells separating regions having different plasma potentials are often found in laboratory experiments. In order to exist, such structures all must find a solution to a common problem. Ions created by charge exchange or ionization in the region of the potential well are electrostatically confined and tend to accumulate and fill up the potential well. The increase in positive charge should eliminate the well. Nevertheless, steady state structures are found in which the wells do not fill up. This means that it is important to take into account processes which 'pump' ions from the well. As examples of ion pumping of plasma wells, potential dips in front of a positively biased electro collecting anode in a relatively cold, low density multidipole plasma is considered. Pumping is provided by ion leaks from the edges of the potential dip or by oscillating the applied potential. In the former case the two dimensional character of the problem is shown to be important.

  3. Insulin regulation of Na/K pump activity in rat hepatoma cells

    International Nuclear Information System (INIS)

    Insulin rapidly increases Na/K pump activity in HTC rat hepatoma cells in tissue culture, as measured by the ouabain-sensitive influx of the potassium analogue 86Rb+. Increased influx is observed within minutes and is maximal (70% above control) within 1-2 h. The effect appears to be mediated by the insulin receptors, as: the concentration dependence on insulin is identical to that for insulin induction of tyrosine aminotransferase and stimulation of 2-aminoisobutyric acid transport, proinsulin is 6% as potent as insulin, and the effect is blocked by anti-receptor antibodies. The early stimulation of potassium influx is not blocked by cycloheximide and is not associated with an increased number of pump sites as measured by 3H-ouabain binding. The insulin effect is blocked by amiloride, which blocks sodium influx, and is mimicked by the sodium ionophore monensin, which increases sodium influx and intracellular accumulation. Insulin also rapidly increases the initial rate of 22Na+ influx, suggesting that insulin may enhance Na/K pump activity, in part, by increasing intracellular sodium concentration. Incubation of HTC cells with insulin for 24 h causes complete unresponsiveness to the insulin induction of transaminase and stimulation of amino acid transport, a phenomenon mediated by postbinding mechanisms. In contrast, similar incubation with insulin does not cause unresponsiveness to the insulin stimulation of Na/K pump activity. Therefore, the site of regulation of responsiveness to insulin must be distal to, or separate from, those events causing stimulation of ion fluxes

  4. Insulin regulation of Na/K pump activity in rat hepatoma cells

    Energy Technology Data Exchange (ETDEWEB)

    Gelehrter, T.D.; Shreve, P.D.; Dilworth, V.M.

    1984-05-01

    Insulin rapidly increases Na/K pump activity in HTC rat hepatoma cells in tissue culture, as measured by the ouabain-sensitive influx of the potassium analogue 86Rb+. Increased influx is observed within minutes and is maximal (70% above control) within 1-2 h. The effect appears to be mediated by the insulin receptors, as: the concentration dependence on insulin is identical to that for insulin induction of tyrosine aminotransferase and stimulation of 2-aminoisobutyric acid transport, proinsulin is 6% as potent as insulin, and the effect is blocked by anti-receptor antibodies. The early stimulation of potassium influx is not blocked by cycloheximide and is not associated with an increased number of pump sites as measured by /sup 3/H-ouabain binding. The insulin effect is blocked by amiloride, which blocks sodium influx, and is mimicked by the sodium ionophore monensin, which increases sodium influx and intracellular accumulation. Insulin also rapidly increases the initial rate of /sup 22/Na+ influx, suggesting that insulin may enhance Na/K pump activity, in part, by increasing intracellular sodium concentration. Incubation of HTC cells with insulin for 24 h causes complete unresponsiveness to the insulin induction of transaminase and stimulation of amino acid transport, a phenomenon mediated by postbinding mechanisms. In contrast, similar incubation with insulin does not cause unresponsiveness to the insulin stimulation of Na/K pump activity. Therefore, the site of regulation of responsiveness to insulin must be distal to, or separate from, those events causing stimulation of ion fluxes.

  5. Knockdown of NBCe1 In Vivo Compromises the Corneal Endothelial Pump

    OpenAIRE

    Liu, Cailing; Cheng, Qiang; Nguyen, Tracy; Bonanno, Joseph A

    2010-01-01

    Sodium bicarbonate cotransporter (NBC) expression was reduced in corneal endothelium by lentiviral delivery of shRNA. Corneal thickness in these eyes showed greater sensitivity to the topical carbonic anhydrase inhibitor brinzolamide, indicating that NBC works in conjunction with carbonic anhydrases as a component of the corneal endothelial pump.

  6. 21 CFR 184.1736 - Sodium bicarbonate.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Sodium bicarbonate. 184.1736 Section 184.1736 Food... Specific Substances Affirmed as GRAS § 184.1736 Sodium bicarbonate. (a) Sodium bicarbonate (NaHCO3, CAS Reg. No. 144-55-8) is prepared by treating a sodium carbonate or a sodium carbonate and sodium...

  7. A Magnetically Coupled Cryogenic Pump

    Science.gov (United States)

    Hatfield, Walter; Jumper, Kevin

    2011-01-01

    Historically, cryogenic pumps used for propellant loading at Kennedy Space Center (KSC) and other NASA Centers have a bellows mechanical seal and oil bath ball bearings, both of which can be problematic and require high maintenance. Because of the extremely low temperatures, the mechanical seals are made of special materials and design, have wearing surfaces, are subject to improper installation, and commonly are a potential leak path. The ball bearings are non-precision bearings [ABEC-1 (Annular Bearing Engineering Council)] and are lubricated using LOX compatible oil. This oil is compatible with the propellant to prevent explosions, but does not have good lubricating properties. Due to the poor lubricity, it has been a goal of the KSC cryogenics community for the last 15 years to develop a magnetically coupled pump, which would eliminate these two potential issues. A number of projects have been attempted, but none of the pumps was a success. An off-the-shelf magnetically coupled pump (typically used with corrosive fluids) was procured that has been used for hypergolic service at KSC. The KSC Cryogenics Test Lab (CTL) operated the pump in cryogenic LN2 as received to determine a baseline for modifications required. The pump bushing, bearings, and thrust rings failed, and the pump would not flow liquid (this is a typical failure mode that was experienced in the previous attempts). Using the knowledge gained over the years designing and building cryogenic pumps, the CTL determined alternative materials that would be suitable for use under the pump design conditions. The CTL procured alternative materials for the bearings (bronze, aluminum bronze, and glass filled PTFE) and machined new bearing bushings, sleeves, and thrust rings. The designed clearances among the bushings, sleeves, thrust rings, case, and case cover were altered once again using experience gained from previous cryogenic pump rebuilds and designs. The alternative material parts were assembled into

  8. CFD Modeling of Sodium Fires

    International Nuclear Information System (INIS)

    A sodium cooled fast reactor is one of the attractive concepts for the 4th generation nuclear reactors. For the safety of a sodium cooled fast reactor, sodium-air and sodium-water reactions must be avoided. A sodium-air reaction typically occurs in two dominant modes, namely the spray fire and the pool fire. To avoid sodium-air accidents and to deal with their consequences, it is essential to understand the physical phenomena. Numerical modeling is one of the methods, which can be used to understand all the physics involved. This paper will present new numerical methods to model sodium pool combustion based on advanced state-of-the-art Computational Fluid Dynamics techniques. The models have been developed, implemented and validated against available experimental data of Newman and Payne. (author)

  9. A miniature intraventricular axial flow blood pump that is introduced through the left ventricular apex.

    Science.gov (United States)

    Yamazaki, K; Umezu, M; Koyanagi, H; Kitamura, M; Eishi, K; Kawai, A; Tagusari, O; Niinami, H; Akimoto, T; Nojiri, C

    1992-01-01

    A new intraventricular axial flow blood pump has been designed and developed as an implantable left ventricular assist device (LVAD). The pump consists of a tube housing (10 cm in length and 14 mm in diameter), a three-vane impeller combined with a guide vane, and a DC motor. This pump is introduced into the LV cavity through the LV apex, and the outlet cannula is passed antegrade across the aortic valve. Blood is withdrawn from the LV through the inlet ports at the pump base, and discharged into the ascending aorta. A pump flow of > 8 L/min was obtained against 90 mmHg differential pressure in the mock circulatory system. In an acute dog model, this pump could produce a sufficient output of 200 ml/kg/min. In addition, the pump flow profile demonstrated a pulsatile pattern, although the rotation speed was fixed. This is mainly due to the changes in flow rate during a cardiac cycle--that is, during systole, the flow rate increases to the maximum, while the differential pressure between the LV and the aorta decreases to the minimum. Thus, this simple and compact axial flow blood pump can be a potential LVAD, with prompt accessibility and need for less invasive surgical procedures.

  10. Roller and Centrifugal Pumps: A Retrospective Comparison of Bleeding Complications in Extracorporeal Membrane Oxygenation.

    Science.gov (United States)

    Halaweish, Ihab; Cole, Adam; Cooley, Elaine; Lynch, William R; Haft, Jonathan W

    2015-01-01

    Centrifugal pumps are increasingly used for extracorporeal membrane oxygenation (ECMO) rather than roller pumps. However, shear forces induced by these types of continuousflow pumps are associated with acquired von Willebrand factor deficiency and bleeding complications. This study was undertaken to compare adverse bleeding complications with the use of centrifugal and roller pumps in patients on prolonged ECMO support. The records of all adult ECMO patients from June 2002 to 2013 were retrospectively reviewed using the University of Michigan Health System database and the Extracorporeal Life Support Organization registry, focusing on patients supported for at least 5 days. Ninety-five ECMO patients met criteria for inclusion (48 roller vs. 47 centrifugal pump). Indications included pulmonary (79%), cardiac (15%), and extracorporeal cardiopulmonary resuscitation (6%), without significant difference between the two groups. Despite lower heparin anticoagulation (10.9 vs. 13.7 IU/kg/hr) with centrifugal pumps, there was a higher incidence of nonsurgical bleeding (gastrointestinal, pulmonary, and neurological) in centrifugal pump patients (26.1 vs. 9.0 events/1,000 patient-days, p = 0.024). In conclusion, in our historical comparison, despite reduced anticoagulation, ECMO support using centrifugal pumps was associated with a higher incidence of nonsurgical bleeding. The mechanisms behind this are multifactorial and require further investigation.

  11. Roller and Centrifugal Pumps: A Retrospective Comparison of Bleeding Complications in Extracorporeal Membrane Oxygenation.

    Science.gov (United States)

    Halaweish, Ihab; Cole, Adam; Cooley, Elaine; Lynch, William R; Haft, Jonathan W

    2015-01-01

    Centrifugal pumps are increasingly used for extracorporeal membrane oxygenation (ECMO) rather than roller pumps. However, shear forces induced by these types of continuousflow pumps are associated with acquired von Willebrand factor deficiency and bleeding complications. This study was undertaken to compare adverse bleeding complications with the use of centrifugal and roller pumps in patients on prolonged ECMO support. The records of all adult ECMO patients from June 2002 to 2013 were retrospectively reviewed using the University of Michigan Health System database and the Extracorporeal Life Support Organization registry, focusing on patients supported for at least 5 days. Ninety-five ECMO patients met criteria for inclusion (48 roller vs. 47 centrifugal pump). Indications included pulmonary (79%), cardiac (15%), and extracorporeal cardiopulmonary resuscitation (6%), without significant difference between the two groups. Despite lower heparin anticoagulation (10.9 vs. 13.7 IU/kg/hr) with centrifugal pumps, there was a higher incidence of nonsurgical bleeding (gastrointestinal, pulmonary, and neurological) in centrifugal pump patients (26.1 vs. 9.0 events/1,000 patient-days, p = 0.024). In conclusion, in our historical comparison, despite reduced anticoagulation, ECMO support using centrifugal pumps was associated with a higher incidence of nonsurgical bleeding. The mechanisms behind this are multifactorial and require further investigation. PMID:25914954

  12. Design of a centrifugal blood pump: Heart Turcica Centrifugal.

    Science.gov (United States)

    Demir, Onur; Biyikli, Emre; Lazoglu, Ismail; Kucukaksu, Suha

    2011-07-01

    A prototype of a new implantable centrifugal blood pump system named Heart Turcica Centrifugal (HTC) was developed as a left ventricular assist device (LVAD) for the treatment of end-stage cardiac failure. In the development of HTC, effects of blade height and volute tongue profiles on the hydraulic and hemolytic performances of the pump were investigated. As a result, the prototype was manufactured using the best blade height and volute tongue profiles. Performance of the prototype model was experimentally evaluated in a closed-loop flow system using water as the medium. The hydraulic performance requirement of an LVAD (5 L/min flow rate against a pressure difference of 100 mm Hg) was attained at 2800 rpm rotational speed.

  13. Cardiac arrest – cardiopulmonary resuscitation

    Directory of Open Access Journals (Sweden)

    Basri Lenjani

    2014-01-01

    Conclusions: All survivors from cardiac arrest have received appropriate medical assistance within 10 min from attack, which implies that if cardiac arrest occurs near an institution health care (with an opportunity to provide the emergent health care the rate of survival is higher.

  14. Leadership in cardiac surgery.

    Science.gov (United States)

    Rao, Christopher; Patel, Vanash; Ibrahim, Michael; Ahmed, Kamran; Wong, Kathie A; Darzi, Ara; von Segesser, Ludwig K; Athanasiou, Thanos

    2011-06-01

    Despite the efficacy of cardiac surgery, less invasive interventions with more uncertain long-term outcomes are increasingly challenging surgery as first-line treatment for several congenital, degenerative and ischemic cardiac diseases. The specialty must evolve if it is to ensure its future relevance. More importantly, it must evolve to ensure that future patients have access to treatments with proven long-term effectiveness. This cannot be achieved without dynamic leadership; however, our contention is that this is not enough. The demands of a modern surgical career and the importance of the task at hand are such that the serendipitous emergence of traditional charismatic leadership cannot be relied upon to deliver necessary change. We advocate systematic analysis and strategic leadership at a local, national and international level in four key areas: Clinical Care, Research, Education and Training, and Stakeholder Engagement. While we anticipate that exceptional individuals will continue to shape the future of our specialty, the creation of robust structures to deliver collective leadership in these key areas is of paramount importance. PMID:20884217

  15. Interventional cardiac catheterization.

    Science.gov (United States)

    Pihkala, J; Nykanen, D; Freedom, R M; Benson, L N

    1999-04-01

    Over the past decade, transcatheter interventions have become increasingly important in the treatment of patients with congenital heart lesions. These procedures may be broadly grouped as dilations (e.g., septostomy, valvuloplasty, angioplasty, and endovascular stenting) or as closures (e.g., vascular embolization and device closure of defects). Balloon valvuloplasty has become the treatment of choice for patients in all age groups with simple valvar pulmonic stenosis and, although not curative, seems at least comparable to surgery for congenital aortic stenosis in newborns to young adults. Balloon angioplasty is successfully applied to a wide range of aortic, pulmonary artery, and venous stenoses. Stents are useful in dilating lesions of which the intrinsic elasticity results in vessel recoil after balloon dilation alone. Catheter-delivered coils are used to embolize a wide range of arterial, venous, and prosthetic vascular connections. Although some devices remain investigational, they have been successfully used for closure of many arterial ducts and atrial and ventricular septal defects. In the therapy for patients with complex CHD, best results may be achieved by combining cardiac surgery with interventional catheterization. The cooperation among interventional cardiologists and cardiac surgeons was highlighted in a report of an algorithm to manage patients with tetralogy of Fallot or pulmonary atresia with diminutive pulmonary arteries, involving balloon dilation, coil embolization of collaterals, and intraoperative stent placement. In this setting, well-planned catheterization procedures have an important role in reducing the overall number of procedures that patients may require over a lifetime, with improved outcomes.

  16. Ictal Cardiac Ryhthym Abnormalities.

    Science.gov (United States)

    Ali, Rushna

    2016-01-01

    Cardiac rhythm abnormalities in the context of epilepsy are a well-known phenomenon. However, they are under-recognized and often missed. The pathophysiology of these events is unclear. Bradycardia and asystole are preceded by seizure onset suggesting ictal propagation into the cortex impacting cardiac autonomic function, and the insula and amygdala being possible culprits. Sudden unexpected death in epilepsy (SUDEP) refers to the unanticipated death of a patient with epilepsy not related to status epilepticus, trauma, drowning, or suicide. Frequent refractory generalized tonic-clonic seizures, anti-epileptic polytherapy, and prolonged duration of epilepsy are some of the commonly identified risk factors for SUDEP. However, the most consistent risk factor out of these is an increased frequency of generalized tonic-clonic seizures (GTC). Prevention of SUDEP is extremely important in patients with chronic, generalized epilepsy. Since increased frequency of GTCS is the most consistently reported risk factor for SUDEP, effective seizure control is the most important preventive strategy. PMID:27347227

  17. Pneumothorax in cardiac pacing

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard;

    2012-01-01

    AIM: To identify risk factors for pneumothorax treated with a chest tube after cardiac pacing device implantation in a population-based cohort.METHODS AND RESULTS: A nationwide cohort study was performed based on data on 28 860 patients from the Danish Pacemaker Register, which included all Danish...... patients who received their first pacemaker (PM) or cardiac resynchronization device from 1997 to 2008. Multiple logistic regression was used to estimate adjusted odds ratios (aOR) with 95% confidence intervals for the association between risk factors and pneumothorax treated with a chest tube. The median...... age was 77 years (25th and 75th percentile: 69-84) and 55% were male (n = 15 785). A total of 190 patients (0.66%) were treated for pneumothorax, which was more often in women [aOR 1.9 (1.4-2.6)], and in patients with age >80 years [aOR 1.4 (1.0-1.9)], a prior history of chronic obstructive pulmonary...

  18. Bioinspired Artificial Sodium and Potassium Ion Channels.

    Science.gov (United States)

    Rodríguez-Vázquez, Nuria; Fuertes, Alberto; Amorín, Manuel; Granja, Juan R

    2016-01-01

    In Nature, all biological systems present a high level of compartmentalization in order to carry out a wide variety of functions in a very specific way. Hence, they need ways to be connected with the environment for communication, homeostasis equilibrium, nutrition, waste elimination, etc. The biological membranes carry out these functions; they consist of physical insulating barriers constituted mainly by phospholipids. These amphipathic molecules spontaneously aggregate in water to form bilayers in which the polar groups are exposed to the aqueous media while the non-polar chains self-organize by aggregating to each other to stay away from the aqueous media. The insulating properties of membranes are due to the formation of a hydrophobic bilayer covered at both sides by the hydrophilic phosphate groups. Thus, lipophilic molecules can permeate the membrane freely, while the small charged or very hydrophilic molecules require the assistance of other membrane components in order to overcome the energetic cost implied in crossing the non-polar region of the bilayer. Most of the large polar species (such as oligosaccharides, polypeptides or nucleic acids) cross into and out of the cell via endocytosis and exocytosis, respectively. Nature has created a series of systems (carriers and pores) in order to control the balance of small hydrophilic molecules and ions. The most important structures to achieve these goals are the ionophoric proteins that include the channel proteins, such as the sodium and potassium channels, and ionic transporters, including the sodium/potassium pumps or calcium/sodium exchangers among others. Inspired by these, scientists have created non-natural synthetic transporting structures to mimic the natural systems. The progress in the last years has been remarkable regarding the efficient transport of Na(+) and K(+) ions, despite the fact that the selectivity and the ON/OFF state of the non-natural systems remain a present and future challenge

  19. PUMPED LASER SYSTEM USING FEEDBACK TO PUMP MEANS

    DEFF Research Database (Denmark)

    2008-01-01

    A laser system according to the invention comprises pump generating means (xO2, xO3) for generating at least a first and a second, preferably focused, pump beam, and lasing means (xO6, xO7) for emitting radiation by being appropriately pumped. The lasing means (xO6, xO7) is disposed in a first...... resonator so as to receive the first pump beam in order to generate a first beam (x21) having a first frequency, and the lasing means (xO6, xO7) is disposed in a second resonator so as to receive the second pump beam in order to generate a second beam (x22) having a second frequency. At least one Q...... fed back to a regulation system (x14), said regulation system (x14) controlling said pump generating means (xO2, xO3)....

  20. Affect intensity and cardiac arousal.

    Science.gov (United States)

    Blascovich, J; Brennan, K; Tomaka, J; Kelsey, R M; Hughes, P; Coad, M L; Adlin, R

    1992-07-01

    Relationships between affect intensity and basal, evoked, and perceived cardiac arousal were investigated in 3 experiments. Affect intensity was assessed using Larsen and Diener's (1987) Affect Intensity Measure (AIM). Cardiac arousal was evoked with exercise in the 1st study and with mental arithmetic in the 2nd and 3rd. Perceived cardiac arousal was measured under optimal conditions using a standard heartbeat discrimination procedure. Women as a group scored higher on the AIM. Affect intensity was unrelated to basal or evoked cardiac arousal and was negatively related to perceived cardiac arousal in all 3 studies. Data suggest that affect intensity, although unrelated to actual physiological arousal, is negatively related to the accuracy with which individuals perceive their own arousal. Results are discussed within the context of an expanded arousal-regulation model (Blascovich, 1990). PMID:1494983

  1. Experimental Study on Series Operation of Sliding Vane Pump and Centrifugal Pump

    OpenAIRE

    Tao Li; Weiming Zhang; Ming Jiang; Zhengyang Li

    2013-01-01

    A platform for sliding vane pump and centrifugal pump tests is installed to study the series operation of them under different characteristics of pipeline. Firstly, the sliding vane pump and the centrifugal pump work independently, and the performance is recorded. Then, the two types of pumps are combined together, with the sliding vane pump acting as the feeding pump. Comparison is made between the performance of the independently working pump and the performance of series operation pump. Re...

  2. Supercritical waste oxidation pump investigation

    International Nuclear Information System (INIS)

    This report investigates the pumping techniques and pumping equipment that would be appropriate for a 5,000 gallon per day supercritical water oxidation waste disposal facility. The pumps must boost water, waste, and additives from atmospheric pressure to approximately 27.6 MPa (4,000 psia). The required flow ranges from 10 gpm to less than 0.1 gpm. For the higher flows, many commercial piston pumps are available. These pumps have packing and check-valves that will require periodic maintenance; probably at 2 to 6 month intervals. Several commercial diaphragm pumps were also discovered that could pump the higher flow rates. Diaphragm pumps have the advantage of not requiring dynamic seals. For the lower flows associated with the waste and additive materials, commercial diaphragm pumps. are available. Difficult to pump materials that are sticky, radioactive, or contain solids, could be injected with an accumulator using an inert gas as the driving mechanism. The information presented in this report serves as a spring board for trade studies and the development of equipment specifications

  3. Supercritical waste oxidation pump investigation

    Energy Technology Data Exchange (ETDEWEB)

    Thurston, G.; Garcia, K.

    1993-02-01

    This report investigates the pumping techniques and pumping equipment that would be appropriate for a 5,000 gallon per day supercritical water oxidation waste disposal facility. The pumps must boost water, waste, and additives from atmospheric pressure to approximately 27.6 MPa (4,000 psia). The required flow ranges from 10 gpm to less than 0.1 gpm. For the higher flows, many commercial piston pumps are available. These pumps have packing and check-valves that will require periodic maintenance; probably at 2 to 6 month intervals. Several commercial diaphragm pumps were also discovered that could pump the higher flow rates. Diaphragm pumps have the advantage of not requiring dynamic seals. For the lower flows associated with the waste and additive materials, commercial diaphragm pumps. are available. Difficult to pump materials that are sticky, radioactive, or contain solids, could be injected with an accumulator using an inert gas as the driving mechanism. The information presented in this report serves as a spring board for trade studies and the development of equipment specifications.

  4. RP-200: Design of PD pump for pumping of molasses

    OpenAIRE

    Skåtun, Kim

    2008-01-01

    Abstract Motivation There is, at the present time, no submerged molasses pump on the market that is designed specifically for cargo tankers. Due to this I, find it interesting to look into the possibilities of installing a molasses pump in cargo tankers to transport molasses instead of transporting molasses in containers as it is done today. It is challenging to come up with a new product, and the motivation of actual be able to release a pump for the international marked is indescribable...

  5. Performance of a hybrid chemical/mechanical heat pump

    Science.gov (United States)

    Silvestri, John J.; Scaringe, Robert P.; Grzyll, Lawrence R.

    1990-01-01

    The authors present the design and preliminary results of the performance of a hybrid chemical/mechanical, low-lift (20 C) heat pump. Studies have indicated that this heat pump has several advantages over the traditional single fluid vapor compression (reverse Rankine) heat pump. Included in these benefits are: 1) increased COPc due to the approximation of the cycle to the Lorenz cycle and due to the availability of the heat of solution, along with the heat of vaporization, to provide cooling; and 2) ease of variation in system cooling capacity by changing the fluid composition. The system performance is predicted for a variety of refrigerant-absorbent pairs. Cooling capacity is determined for systems operating with ammonia as the refrigerant and lithium nitrate and sodium thiocyanate as the absorbents and also with water as the refrigerant and magnesium chloride, potassium hydroxide, lithium bromide, sodium hydroxide, and sulfuric acid as the absorbents. Early indications have shown that the systems operating with water as the refrigerant operate at 2-4 times the capacity of the ammonia-refrigerant-based systems. Using existing working fluids in the proposed innovative design, a coefficient-of-performance improvement of 21 percent is possible when compared to the best vapor compression systems analyzed.

  6. High-resolution lidar system for measuring the spatial and temporal structure of the mesospheric sodium layer

    Science.gov (United States)

    Gardner, C. S.; Sechrist, C. F., Jr.; Shelton, J. D.

    1983-01-01

    The design of a high-resolution tunable-dye laser-based lidar system for the study of the mesospheric sodium layer is presented and results of sodium measurements are indicated. The lidar system comprises a tunable flashlamp-pumped dye laser operating at the sodium D2 resonance line at 589.0 nm with a pulse width of 2 microsec FWHM and pulse frequency of 10 Hz and a telescope with a 1.22=m diameter Fresnel lens. Sodium profiles are obtained from the integration of 100 to 250 laser shots, with spatial and temporal resolution enhanced by two-dimensional filtering techniques. Measurements obtained over a 9-hour nighttime period illustrate the highly dynamic nature of the sodium layer, which was observed with a spatial resolution of 2 km and temporal resolution of 30 min. Observations made with a steerable apparatus have confirmed a presunrise enhancement of over 100 percent in sodium column abundance.

  7. Sodium ion channel mutations in glioblastoma patients correlate with shorter survival

    Directory of Open Access Journals (Sweden)

    Velculescu Victor E

    2011-02-01

    Full Text Available Abstract Background Glioblastoma Multiforme (GBM is the most common and invasive astrocytic tumor associated with dismal prognosis. Treatment for GBM patients has advanced, but the median survival remains a meager 15 months. In a recent study, 20,000 genes from 21 GBM patients were sequenced that identified frequent mutations in ion channel genes. The goal of this study was to determine whether ion channel mutations have a role in disease progression and whether molecular targeting of ion channels is a promising therapeutic strategy for GBM patients. Therefore, we compared GBM patient survival on the basis of presence or absence of mutations in calcium, potassium and sodium ion transport genes. Cardiac glycosides, known sodium channel inhibitors, were then tested for their ability to inhibit GBM cell proliferation. Results Nearly 90% of patients showed at least one mutation in ion transport genes. GBM patients with mutations in sodium channels showed a significantly shorter survival compared to patients with no sodium channel mutations, whereas a similar comparison based on mutational status of calcium or potassium ion channel mutations showed no survival differences. Experimentally, targeting GBM cells with cardiac glycosides such as digoxin and ouabain demonstrated preferential cytotoxicity against U-87 and D54 GBM cells compared to non-tumor astrocytes (NTAs. Conclusions These pilot studies of GBM patients with sodium channel mutations indicate an association with a more aggressive disease and significantly shorter survival. Moreover, inhibition of GBM cells by ion channel inhibitors such as cardiac glycosides suggest a therapeutic strategy with relatively safe drugs for targeting GBM ion channel mutations. Key Words: glioblastoma multiforme, ion channels, mutations, small molecule inhibitors, cardiac glycosides.

  8. Internal brain motion pumping of CSF using high-resolution velocity MR imaging

    International Nuclear Information System (INIS)

    An MR velocity density (MRVD) technique able to detect velocities as low as 0.4 mm/sec was applied to obtain images of the brain synchronized to the cardiac cycle in 25 healthy subjects and five patients. During systole (100-200 msec after the R wave), MRVD images demonstrated a caudad velocity in the central regions of the brain, most prominent in the brain stem (up to 1.5 mm/sec). This caudad brain motion and the synchronous ejection of cerebrospinal fluid (CSF) from the ventricles into the basal cisterns, taken together, strongly suggest a cardiac-driven pumping action of the brain on the CSF

  9. Novel limiter pump topologies

    Energy Technology Data Exchange (ETDEWEB)

    Schultz, J.H.

    1981-01-01

    The use of limiter pumps as the principle plasma exhaust system of a magnetic confinement fusion device promises significant simplification, when compared to previously investigating divertor based systems. Further simplifications, such as the integration of the exhaust system with a radio frequency heating system and with the main reactor shield and structure are investigated below. The integrity of limiters in a reactor environment is threatened by many mechanisms, the most severe of which may be erosion by sputtering. Two novel topolgies are suggested which allow high erosion without limiter failure.

  10. Magnetometry with Mesospheric Sodium

    CERN Document Server

    Higbie, J M; Patton, B; Holzlöhner, R; Calia, D Bonaccini; Budker, D

    2009-01-01

    Measurement of magnetic fields on the few-hundred-kilometer length scale is significant for a variety of geophysical applications including mapping of crustal magnetism and ocean-circulation measurements, yet available techniques for such measurements are very expensive or of limited accuracy. We propose a scheme for remote detection of magnetic fields using the naturally occurring atomic-sodium-rich layer in the mesosphere and existing high-power lasers developed for laser guide-star applications. The proposed scheme offers dramatic reduction in cost, opening the way to large-scale magnetic mapping missions.

  11. Magnetometry with mesospheric sodium

    Science.gov (United States)

    Higbie, James M.; Rochester, Simon M.; Patton, Brian; Holzlöhner, Ronald; Bonaccini Calia, Domenico; Budker, Dmitry

    2011-01-01

    Measurement of magnetic fields on the few 100-km length scale is significant for many geophysical applications including mapping of crustal magnetism and ocean circulation measurements, yet available techniques for such measurements are very expensive or of limited accuracy. We propose a method for remote detection of magnetic fields using the naturally occurring atomic sodium-rich layer in the mesosphere and existing high-power lasers developed for laser guide star applications. The proposed method offers a dramatic reduction in cost and opens the way to large-scale, parallel magnetic mapping and monitoring for atmospheric science, navigation, and geophysics. PMID:21321235

  12. Effects of sodium intake on cardiovascular variables in humans during posture changes and ambulatory conditions

    DEFF Research Database (Denmark)

    Damgaard, Morten; Gabrielsen, Anders; Heer, Martina;

    2002-01-01

    and controlled laboratory conditions at the end of two consecutive 5-day periods with sodium intakes of 70 (low) and 250 (high) mmol/24 h or vice versa, respectively. Comparing high and low sodium intake, plasma volume and plasma protein concentrations were 9 and 8% higher in the seated and the supine position......The hypothesis was tested that cardiac output (CO) and stroke volume (SV) are increased by a moderate physiological elevation in sodium intake with a more pronounced effect in the ambulatory upright seated than supine position. Fourteen healthy males were investigated during ambulatory......, respectively. When seated during laboratory conditions, CO was 5.3 +/- 0.2 l/min on the high sodium intake vs. 4.8 +/- 0.2 l/min on the low (P intake...

  13. Centrifugal pumps and allied machinery

    CERN Document Server

    Anderson, HH

    1994-01-01

    This book will be of vital interest to all engineers and designers concerned with centrifugal pumps and turbines. Including statistical information derived from 20000 pumps and 700 turbines with capacities of 5gpm to 5000000gpm, this book offers the widest range and scope of information currently available. Statistical analyses suggest practical methods of increasing pump performance and provide valuable data for new design aspects.

  14. Spin pumping through quantum dots

    OpenAIRE

    Rojek, Stephan; Governale, Michele; König, Jürgen

    2013-01-01

    We propose schemes for generating spin currents into a semiconductor by adiabatic or non-adiabatic pumping of electrons through interacting quantum dots. The appeal of such schemes lies in the possibility to tune the pumping characteristics via gate voltages that control the properties of the quantum dot. The calculations are based on a systematic perturbation expansion in the tunnel-coupling strength and the pumping frequency, expressed within a diagrammatic real-time technique. Special focu...

  15. Research on synchronous gear pump

    Institute of Scientific and Technical Information of China (English)

    LUAN Zhen-hui

    2010-01-01

    Based on a comprehensive analysis of the structure and existing problems of the gear pump, provided a structure principle of a synchronous gear pump. The discussions focused on the working principle, construction features and finite element analysis of the hydraulic gear. The research indicates that the new pump has such advantages as lower noise, better distributed flow and a high work pressure, and it can be widely used in hydraulic systems.

  16. Structural Mechanism for Light-driven Transport by a New Type of Chloride Ion Pump, Nonlabens marinus Rhodopsin-3.

    Science.gov (United States)

    Hosaka, Toshiaki; Yoshizawa, Susumu; Nakajima, Yu; Ohsawa, Noboru; Hato, Masakatsu; DeLong, Edward F; Kogure, Kazuhiro; Yokoyama, Shigeyuki; Kimura-Someya, Tomomi; Iwasaki, Wataru; Shirouzu, Mikako

    2016-08-19

    The light-driven inward chloride ion-pumping rhodopsin Nonlabens marinus rhodopsin-3 (NM-R3), from a marine flavobacterium, belongs to a phylogenetic lineage distinct from the halorhodopsins known as archaeal inward chloride ion-pumping rhodopsins. NM-R3 and halorhodopsin have distinct motif sequences that are important for chloride ion binding and transport. In this study, we present the crystal structure of a new type of light-driven chloride ion pump, NM-R3, at 1.58 Å resolution. The structure revealed the chloride ion translocation pathway and showed that a single chloride ion resides near the Schiff base. The overall structure, chloride ion-binding site, and translocation pathway of NM-R3 are different from those of halorhodopsin. Unexpectedly, this NM-R3 structure is similar to the crystal structure of the light-driven outward sodium ion pump, Krokinobacter eikastus rhodopsin 2. Structural and mutational analyses of NM-R3 revealed that most of the important amino acid residues for chloride ion pumping exist in the ion influx region, located on the extracellular side of NM-R3. In contrast, on the opposite side, the cytoplasmic regions of K. eikastus rhodopsin 2 were reportedly important for sodium ion pumping. These results provide new insight into ion selection mechanisms in ion pumping rhodopsins, in which the ion influx regions of both the inward and outward pumps are important for their ion selectivities. PMID:27365396

  17. Aggravated Cardiac Remodeling post Aortocaval Fistula in Unilateral Nephrectomized Rats.

    Directory of Open Access Journals (Sweden)

    Jie Wu

    Full Text Available Aortocaval fistula (AV in rat is a unique model of volume-overload congestive heart failure and cardiac hypertrophy. Living donor kidney transplantation is regarded as beneficial to allograft recipients and not particularly detrimental to the donors. Impact of AV on animals with mild renal dysfunction is not fully understood. In this study, we explored the effects of AV in unilateral nephrectomized (UNX rats.Adult male Sprague-Dawley (SD rats were divided into Sham (n = 10, UNX (right kidney remove, n = 10, AV (AV established between the levels of renal arteries and iliac bifurcation, n = 18 and UNX+AV (AV at one week after UNX, n = 22, respectively. Renal outcome was measured by glomerular filtration rate, effective renal plasma flow, fractional excretion of sodium, albuminuria, plasma creatinine, and cystatin C. Focal glomerulosclerosis (FGS incidence was evaluated by renal histology. Cardiac function was measured by echocardiography and hemodynamic measurements.UNX alone induced compensatory left kidney enlargement, increased plasma creatinine and cystatin C levels, and slightly reduced glomerular filtration rate and increased FGS. AV induced significant cardiac enlargement and hypertrophy and reduced cardiac function and increased FGS, these changes were aggravated in UNX+AV rats.Although UNX only induces minor renal dysfunction, additional chronic volume overload placement during the adaptation phase of the remaining kidney is associated with aggravated cardiac dysfunction and remodeling in UNX rats, suggesting special medical care is required for UNX or congenital monokidney subjects in case of chronic volume overload as in the case of pregnancy and hyperthyroidism to prevent further adverse cardiorenal events in these individuals.

  18. Mediastinitis after cardiac transplantation

    Directory of Open Access Journals (Sweden)

    Noedir A. G. Stolf

    2000-05-01

    Full Text Available OBJECTIVE: Assessment of incidence and behavior of mediastinitis after cardiac transplantation. METHODS: From 1985 to 1999, 214 cardiac transplantations were performed, 12 (5.6% of the transplanted patients developed confirmed mediastinitis. Patient's ages ranged from 42 to 66 years (mean of 52.3±10.0 years and 10 (83.3% patients were males. Seven (58.3% patients showed sternal stability on palpation, 4 (33.3% patients had pleural empyema, and 2 (16.7% patients did not show purulent secretion draining through the wound. RESULTS: Staphylococcus aureus was the infectious agent identified in the wound secretion or in the mediastinum, or both, in 8 (66.7% patients. Staphylococcus epidermidis was identified in 2 (16.7% patients, Enterococcus faecalis in 1 (8.3% patient, and the cause of mediastinitis could not be determined in 1 (8.3% patient. Surgical treatment was performed on an emergency basis, and the extension of the débridement varied with local conditions. In 2 (16.7% patients, we chose to leave the surgical wound open and performed daily dressings with granulated sugar. Total sternal resection was performed in only 1 (8.3% patient. Out of this series, 5 (41.7% patients died, and the causes of death were related to the infection. Autopsy revealed persistence of mediastinitis in 1 (8.3% patient. CONCLUSION: Promptness in diagnosing mediastinitis and precocious surgical drainage have changed the natural evolution of this disease. Nevertheless, observance of the basic precepts of prophylaxis of infection is still the best way to treat mediastinitis.

  19. Incidence and management of diaphragmatic palsy in patients after cardiac surgery

    Directory of Open Access Journals (Sweden)

    Mehta Yatin

    2008-01-01

    Full Text Available Background: Diaphragm is the most important part of the respiratory system. Diaphragmatic palsy following cardiac surgery is not uncommon and can cause deterioration of pulmonary functions and attendant pulmonary complications. Objectives: Aim of this study was to observe the incidence of diaphragmatic palsy after off pump coronary artery bypass grafting (OPCAB as compared to conventional CABG and to assess the efficacy of chest physiotherapy on diaphragmatic palsy in post cardiac surgical patients. Design and Setting: An observational prospective interventional study done at a tertiary care cardiac centre. Patients: 2280 consecutive adult patients who underwent cardiac surgery from February 2005 to august 2005. Results: 30 patients out of 2280 (1.31% developed diaphragmatic palsy. Patients were divided based on the presence or absence of symptoms viz. breathlessness at rest or exertion or with the change of posture along with hypoxemia and / or hypercapnia. Group I included 14 patients who were symptomatic (CABG n=13, post valve surgery n=1, While Group II included 16 asymptomatic patients (CABG n=12, post valve surgery n=4, 9 patients (64% from Group I (n=14 and 4 patients (25% from group II showed complete recovery from diaphragmatic palsy as demonstrated ultrasonographically. Conclusion: The incidence of diaphragmatic palsy was remarkably less in our adult cardiac surgical patients because most of the cardiac surgeries were performed off pump and intensive chest physiotherapy beginning shortly after extubation helped in complete or near complete recovery of diaphragmatic palsy. Chest Physiotherapy led to marked improvement in functional outcome following post cardiac surgery diaphragmatic palsy. We also conclude that ultrasonography is a simple valuable bed-side tool for rapid diagnosis of diaphragmatic palsy

  20. Metoclopramide-induced cardiac arrest

    Directory of Open Access Journals (Sweden)

    Martha M. Rumore

    2011-11-01

    Full Text Available The authors report a case of cardiac arrest in a patient receiving intravenous (IV metoclopramide and review the pertinent literature. A 62-year-old morbidly obese female admitted for a gastric sleeve procedure, developed cardiac arrest within one minute of receiving metoclopramide 10 mg via slow intravenous (IV injection. Bradycardia at 4 beats/min immediately appeared, progressing rapidly to asystole. Chest compressions restored vital function. Electrocardiogram (ECG revealed ST depression indicative of myocardial injury. Following intubation, the patient was transferred to the intensive care unit. Various cardiac dysrrhythmias including supraventricular tachycardia (SVT associated with hypertension and atrial fibrillation occurred. Following IV esmolol and metoprolol, the patient reverted to normal sinus rhythm. Repeat ECGs revealed ST depression resolution without pre-admission changes. Metoclopramide is a non-specific dopamine receptor antagonist. Seven cases of cardiac arrest and one of sinus arrest with metoclopramide were found in the literature. The metoclopramide prescribing information does not list precautions or adverse drug reactions (ADRs related to cardiac arrest. The reaction is not dose related but may relate to the IV administration route. Coronary artery disease was the sole risk factor identified. According to Naranjo, the association was possible. Other reports of cardiac arrest, severe bradycardia, and SVT were reviewed. In one case, five separate IV doses of 10 mg metoclopramide were immediately followed by asystole repeatedly. The mechanism(s underlying metoclopramide’s cardiac arrest-inducing effects is unknown. Structural similarities to procainamide may play a role. In view of eight previous cases of cardiac arrest from metoclopramide having been reported, further elucidation of this ADR and patient monitoring is needed. Our report should alert clinicians to monitor patients and remain diligent in surveillance and

  1. The terrestrial silica pump.

    Directory of Open Access Journals (Sweden)

    Joanna C Carey

    Full Text Available Silicon (Si cycling controls atmospheric CO(2 concentrations and thus, the global climate, through three well-recognized means: chemical weathering of mineral silicates, occlusion of carbon (C to soil phytoliths, and the oceanic biological Si pump. In the latter, oceanic diatoms directly sequester 25.8 Gton C yr(-1, accounting for 43% of the total oceanic net primary production (NPP. However, another important link between C and Si cycling remains largely ignored, specifically the role of Si in terrestrial NPP. Here we show that 55% of terrestrial NPP (33 Gton C yr(-1 is due to active Si-accumulating vegetation, on par with the amount of C sequestered annually via marine diatoms. Our results suggest that similar to oceanic diatoms, the biological Si cycle of land plants also controls atmospheric CO(2 levels. In addition, we provide the first estimates of Si fixed in terrestrial vegetation by major global biome type, highlighting the ecosystems of most dynamic Si fixation. Projected global land use change will convert forests to agricultural lands, increasing the fixation of Si by land plants, and the magnitude of the terrestrial Si pump.

  2. The terrestrial silica pump.

    Science.gov (United States)

    Carey, Joanna C; Fulweiler, Robinson W

    2012-01-01

    Silicon (Si) cycling controls atmospheric CO(2) concentrations and thus, the global climate, through three well-recognized means: chemical weathering of mineral silicates, occlusion of carbon (C) to soil phytoliths, and the oceanic biological Si pump. In the latter, oceanic diatoms directly sequester 25.8 Gton C yr(-1), accounting for 43% of the total oceanic net primary production (NPP). However, another important link between C and Si cycling remains largely ignored, specifically the role of Si in terrestrial NPP. Here we show that 55% of terrestrial NPP (33 Gton C yr(-1)) is due to active Si-accumulating vegetation, on par with the amount of C sequestered annually via marine diatoms. Our results suggest that similar to oceanic diatoms, the biological Si cycle of land plants also controls atmospheric CO(2) levels. In addition, we provide the first estimates of Si fixed in terrestrial vegetation by major global biome type, highlighting the ecosystems of most dynamic Si fixation. Projected global land use change will convert forests to agricultural lands, increasing the fixation of Si by land plants, and the magnitude of the terrestrial Si pump. PMID:23300825

  3. Lasers with nuclear pumping

    CERN Document Server

    Melnikov, S P; Sizov, A N; Miley, George H

    2015-01-01

    This book covers the history of lasers with nuclear pumping (Nuclear Pumped Lasers, NPLs). This book showcases the most important results and stages of NPL development in The Russian Federal Nuclear Center (VNIIEF) as well as other Russian and international laboratories, including laboratories in the United States. The basic science and technology behind NPLs along with potential applications are covered throughout the book. As such, this book: ·         Contains a historical overview of the extensive information developed over the past 40 years of work on NPLs ·         Covers the most important results and stages of NPL development, not just in the Russian Federal Nuclear Center, VNIIEF, but also in other laboratories in Russia, the United States , and some other scattered international laboratories ·         Systematizes the fragmented information accumulated over these years of very active research and development As the first comprehensive discussion of NPLs, students, research...

  4. Epigenetic regulation in cardiac fibrosis

    Institute of Scientific and Technical Information of China (English)

    Li-Ming; Yu; Yong; Xu

    2015-01-01

    Cardiac fibrosis represents an adoptive response in the heart exposed to various stress cues. While resolution of the fibrogenic response heralds normalization of heart function, persistent fibrogenesis is usually associated with progressive loss of heart function and eventually heart failure. Cardiac fibrosis is regulated by a myriad of factors that converge on the transcription of genes encoding extracellular matrix proteins, a process the epigenetic machinery plays a pivotal role. In this minireview, we summarize recent advances regarding the epigenetic regulation of cardiac fibrosis focusing on the role of histone and DNA modifications and non-coding RNAs.

  5. Cardiac perioperative complications in noncardiac surgery

    OpenAIRE

    Radovanović Dragana; Kolak Radmila; Stokić Aleksandar; Radovanović Zoran; Jovanović Gordana

    2008-01-01

    Anesthesiologists are confronted with an increasing population of patients undergoing noncardiac surgery who are at risk for cardiac complications in the perioperative period. Perioperative cardiac complications are responsible for significant mortality and morbidity. The aim of the present study was to determine the incidence of perioperative (operative and postoperative) cardiac complications and correlations between the incidence of perioperative cardiac complications and type of surgical ...

  6. Work plan, AP-102 mixer pump removal and pump replacement

    International Nuclear Information System (INIS)

    The objective of this work plan is to plan the steps and estimate the costs required to remove the failed AP-102 mixer pump, and to plan and estimate the cost of the necessary design and specification work required to order a new, but modified, mixer pump including the pump and pump pit energy absorbing design. The main hardware required for the removal of the mixer is as follows: a flexible receiver and blast shield; a metal container for the pulled mixer pump; and a trailer and strongback to haul and manipulate the container. Additionally: a gamma scanning device will be needed to detect the radioactivity emanating from the mixer as it is pulled from the tank; a water spray system will be required to remove tank waste from the surface of the mixer as it is pulled from the AP-102 tank; and a lifting yoke to lift the mixer from the pump pit (the SY-101 Mixer Lifting Yoke will be used). A ''green house'' will have to be erected over the AP-102 pump pit and an experienced Hoisting and Rigging crew must be assembled and trained in mixer pump removal methods before the actual removal is undertaken

  7. Cooling Performance of ALIP according to the Air or Sodium Cooling Type

    International Nuclear Information System (INIS)

    ALIP pumps the liquid sodium by Lorentz force produced by the interaction of induced current in the liquid metal and their associated magnetic field. Even though the efficiency of the ALIP is very low compared to conventional mechanical pumps, it is very useful due to the absence of moving parts, low noise and vibration level, simplicity of flow rate regulation and maintenance, and high temperature operation capability. Problems in utilization of ALIP concern a countermeasure for elevation of internal temperature of the coil due to joule heating and how to increase magnetic flux density of Na channel gap. The conventional ALIP usually used cooling methods by circulating the air or water. On the other hand, GE-Toshiba developed a double stator pump adopting the sodium-immersed self-cooled type, and it recovered the heat loss in sodium. Therefore, the station load factor of the plant could be reduced. In this study, the cooling performance with cooling types of ALIP is analyzed. We developed thermal analysis models to evaluate the cooling performance of air or sodium cooling type of ALIP. The cooling performance is analyzed for operating parameters and evaluated with cooling type. 1-D and 3-D thermal analysis model for IHTS ALIP was developed, and the cooling performance was analyzed for air or sodium cooling type. The cooling performance for air cooling type was better than sodium cooling type at higher air velocity than 0.2 m/s. Also, the air temperature of below 270 .deg. demonstrated the better cooling performance as compared to sodium

  8. The report of inspection and repair technology of sodium cooled reactors

    International Nuclear Information System (INIS)

    considered, and short-term repair methods were investigated for secondary sodium leak from the main piping. The application and issue of the repair methods were discussed for commercialized plants. More specific repair sequence must be developed for each sodium leak location by referring to other plants' repair experience. Furthermore, the repair methods of components such as a pump must be investigated. (author)

  9. Heat-Powered Pump for Liquid Metals

    Science.gov (United States)

    Campana, R. J.

    1986-01-01

    Proposed thermoelectromagnetic pump for liquid metal powered by waste heat; needs no battery, generator, or other external energy source. Pump turns part of heat in liquid metal into pumping energy. In combination with primary pump or on its own, thermoelectric pump circulates coolant between reactor and radiator. As long as there is decay heat to be removed, unit performs function.

  10. About Variable Speed Heating and Cooling Pumps

    OpenAIRE

    Cătălin Popovici; Jan Ignat

    2009-01-01

    The present work has the purpose of underlying the advantages of variable speed heating and cooling pumps use for the perspective of general and particular pumping costs and efficiency. The study approaches comparisons between constant flow pumps and variable flow pumps in different given situations and comparatively analyses the pumping costs.

  11. Sodium quality control; French developments from Rapsodie to EFR

    International Nuclear Information System (INIS)

    In order to operate in reliable and safe conditions a Sodium Fast Reactor, it is necessary to master the quality of the coolant. The chemical control of sodium is performed versus the different chemical compounds : oxygen (corrosion control), hydrogen (detection of the sodium-water reaction), and to a less degree carbon (carburization, decarburization phenomena). Moreover, other detrimental effects could be avoided: plugging of narrow sections, loss of heat transfer efficiency in heat exchangers, contamination and dosimetry,... Oxygen and moisture are introduced mainly during handling operations; hydrogen is due to aqueous corrosion of the Steam Generator Unit and thermal decomposition of hydrazine, used to control the oxygen content in the water.Some specific events can occur and generates pollution of sodium: sodium-water reaction due to water ingress in the intermediate loop, oil ingress from mechanical pumps,... To mitigate the consequences induced by such events, it is necessary to carry out a purification campaign in order to reach the nominal O, H, C content in the sodium, respectively, in France [O]<3 ppm, [H]< 0.1 ppm and [C]<20 ppm. The purification of oxygen and hydrogen is performed satisfactorily thanks to cold traps and mainly because of the fact that the solubilities are nearly nil for temperatures close to the fusion point, i.e. 97.8 deg. C. The sodium is first cooled in a heat-exchanger-economizer to a temperature close to the saturation temperature of oxygen and/or hydrogen. It then flows through a cooler where it reaches a temperature below the saturation temperature. Sodium oxide or hydride crystals form and are retained on a packing which can be a stainless steel knit packing, Pall rings (in Germany),... The retention area may correspond to the cooling area. This process allows to obtain a large trapping capacity and efficiency if the design takes into account some specific rules based on the basic studies related to the mechanisms and kinetics

  12. Minimally invasive cardiac surgery-coronary artery bypass graft.

    Science.gov (United States)

    Lemma, Massimo; Atanasiou, Thanos; Contino, Monica

    2013-01-01

    Coronary artery bypass graft (CABG) is among the most common operations performed in the world. Different surgical strategies can be used with different invasiveness. This paper describes a recent development of the technique that merges the advantages resulting from both the adoption of an 'off-pump no-touch aorta operation' and a 'complete arterial revascularization through a left minithoracotomy' in a single procedure. This operation is currently known with the acronym MICS (minimally invasive cardiac surgery)-CABG (minimally invasive cardiac surgery). It is an off-pump operation performed through a minithoracotomy in the fourth or fifth left intercostal space across the midclavicular line. The left internal thoracic artery (LITA) is harvested under direct vision using a special rib-retractor with multiple interchangeable thoracotomy blades, including blades to use with lift systems for proximal artery harvesting, while the right radial artery (RA) is harvested endoscopically. A Y-connection is made between the two arteries. The LITA is used to bypass the left anterior descending coronary artery, while the right RA is used on the obtuse marginal branches and/or the posterior descending coronary artery. A special coronary stabilizer and a heart positioner with a shaft for remote thoracic insertion are needed.

  13. Proton Pump Inhibitor Use and the Antifracture Efficacy of Alendronate

    DEFF Research Database (Denmark)

    Abrahamsen, Bo; Eiken, Pia Agnete; Eastell, Richard

    2011-01-01

    Background: Proton pump inhibitors (PPIs) are widely used in elderly patients and are frequently coadministered in users of oral bisphosphonates. Biologically, PPIs could affect the absorption of calcium, vitamin B12, and bisphosphonates and could affect the osteoclast proton pump, thus interacting...... no significant impact of concurrent use of histamine H2 receptor blockers. Conclusions: Concurrent PPI use was associated with a dose-dependent loss of protection against hip fracture with alendronate in elderly patients. This is an observational study, so a formal proof of causality cannot be made...... with bisphosphonate antifracture efficacy. Moreover, PPIs themselves have been linked to osteoporotic fractures. Methods: Population-based, national register–based, open cohort study of 38 088 new alendronate sodium users with a mean duration of follow-up of 3.5 years. We related risk of hip fracture...

  14. Sodium waste technology: A summary report

    International Nuclear Information System (INIS)

    The Sodium Waste Technology (SWT) Program was established to resolve long-standing issues regarding disposal of sodium-bearing waste and equipment. Comprehensive SWT research programs investigated a variety of approaches for either removing sodium from sodium-bearing items, or disposal of items containing sodium residuals. The most successful of these programs was the design, test, and the production operation of the Sodium Process Demonstration Facility at ANL-W. The technology used was a series of melt-drain-evaporate operations to remove nonradioactive sodium from sodium-bearing items and then converting the sodium to storable compounds

  15. Laser transmitter for space-based sodium lidar instrument

    Science.gov (United States)

    Yu, Anthony W.; Krainak, Michael A.; Janches, Diego; Konoplev, Oleg

    2016-05-01

    We are currently developing a laser transmitter to remotely measure Sodium (Na) by adapting existing lidar technology with space flight heritage. The developed instrumentation will serve as the core for the planning of a Heliophysics mission targeted to study the composition and dynamics of Earth's mesosphere based on a spaceborne lidar that will measure the mesospheric Na layer. We present performance results from our laser transmitter development effort with emphasis on wavelength tuning and power scaling of a diode-pumped Q-switched self-Raman c-cut Nd:YVO4 laser with intra-cavity frequency doubling that could produce multi-watt 589 nm wavelength output. We will review technologies that provide strong leverage for the sodium lidar laser system with strong heritage from past and current space flight missions.

  16. Improving sodium laser guide star brightness by polarization switching

    Science.gov (United States)

    Fan, Tingwei; Zhou, Tianhua; Feng, Yan

    2016-01-01

    Optical pumping with circularly polarized light has been used to enhance the brightness of sodium laser guide star. But the benefit is reduced substantially due to the precession of sodium atoms in geomagnetic field. Switching the laser between left and right circular polarization at the Larmor frequency is proposed to improve the return. With ESO’s laser guide star system at Paranal as example, numerical simulation shows that the return flux is increased when the angle between geomagnetic field and laser beam is larger than 60°, as much as 50% at 90°. The proposal is significant since most astronomical observation is at angle between 60° and 90° and it only requires a minor addition to the delivery optics of present laser system. PMID:26797503

  17. Final report on the safety assessment of Sodium Metaphosphate, Sodium Trimetaphosphate, and Sodium Hexametaphosphate.

    Science.gov (United States)

    Lanigan, R S

    2001-01-01

    These inorganic polyphosphate salts all function as chelating agents in cosmetic formulations. In addition, Sodium Metaphosphate functions as an oral care agent, Sodium Trimetaphosphate as a buffering agent, and Sodium Hexametaphosphate as a corrosion inhibitor. Only Sodium Hexametaphosphate is currently reported to be used. Although the typical concentrations historically have been less than 1%, higher concentrations have been used in products such as bath oils, which are diluted during normal use. Sodium Metaphosphate is the general term for any polyphosphate salt with four or more phosphate units. The four-phosphate unit version is cyclic, others are straight chains. The hexametaphosphate is the specific six-chain length form. The trimetaphosphate structure is cyclic. Rats fed 10% Sodium Trimetaphosphate for a month exhibited transient tubular necrosis; rats given 10% Sodium Metaphosphate had retarded growth and those fed 10% Sodium Hexametaphosphate had pale and swollen kidneys. In chronic studies using animals, growth inhibition, increased kidney weights (with calcium deposition and desquamation), bone decalcification, parathyroid hypertrophy and hyperplasia, inorganic phosphaturia, hepatic focal necrosis, and muscle fiber size alterations. Sodium Hexametaphosphate was a severe skin irritant in rabbits, whereas a 0.2% solution was only mildly irritating. A similar pattern was seen with ocular toxicity. These ingredients were not genotoxic in bacterial systems nor were they carcinogenic in rats. No reproductive or developmental toxicity was seen in studies using rats exposed to Sodium Hexametaphosphate or Sodium Trimetaphosphate. In clinical testing, irritation is seen as a function of concentration; concentrations as high as 1% produced no irritation in contact allergy patients. Because of the corrosive nature of Sodium Hexametaphosphate, it was concluded that these ingredients could be used safely if each formulation was prepared to avoid skin irritation; for

  18. A cardiac electrical activity model based on a cellular automata system in comparison with neural network model.

    Science.gov (United States)

    Khan, Muhammad Sadiq Ali; Yousuf, Sidrah

    2016-03-01

    Cardiac Electrical Activity is commonly distributed into three dimensions of Cardiac Tissue (Myocardium) and evolves with duration of time. The indicator of heart diseases can occur randomly at any time of a day. Heart rate, conduction and each electrical activity during cardiac cycle should be monitor non-invasively for the assessment of "Action Potential" (regular) and "Arrhythmia" (irregular) rhythms. Many heart diseases can easily be examined through Automata model like Cellular Automata concepts. This paper deals with the different states of cardiac rhythms using cellular automata with the comparison of neural network also provides fast and highly effective stimulation for the contraction of cardiac muscles on the Atria in the result of genesis of electrical spark or wave. The specific formulated model named as "States of automaton Proposed Model for CEA (Cardiac Electrical Activity)" by using Cellular Automata Methodology is commonly shows the three states of cardiac tissues conduction phenomena (i) Resting (Relax and Excitable state), (ii) ARP (Excited but Absolutely refractory Phase i.e. Excited but not able to excite neighboring cells) (iii) RRP (Excited but Relatively Refractory Phase i.e. Excited and able to excite neighboring cells). The result indicates most efficient modeling with few burden of computation and it is Action Potential during the pumping of blood in cardiac cycle. PMID:27087101

  19. Pump rod forces due to hydrodynamic effects in piston pumps

    Energy Technology Data Exchange (ETDEWEB)

    Verheij, F.

    1986-10-01

    A mathematical model has been set up to describe flow and pressure fluctuations in a pump system of a wind pump for single acting piston pumps. With this, hydrodynamic forces acting on the pump rod can be calculated. Hydrodynamic forces make an important contribution to the total pump rod force. Experiments have been performed on a laboratory version of the so-called Tanzania pump. Different air volumes of the delivery airchamber, different delivery heads and different rotational speeds were chosen to obtain enough information to check the validity of the model. For the measuring and the elaboration of the measurements, computer programs were developed using a new data acquisition system. This new system operates very satisfactorily. A new magneto-inductive flow meter has been installed. However there are still incertainties as to the reliability of this sensor. Simple analytical expressions using Fourier transform analysis methods were obtained for the pressure and flow fluctuations in the pump system, from which the forces acting on the pump rod can be calculated. Comparison between theoretical and experimental results suggest that the pressure fluctuations are predicted correctly by theory. This is yet not the case in comparing theory and experiment with regards to the flow fluctuations. Apart from the irreliability of the flow meter, this could also be due to the complex flow in and out of the airchamber that is not correctly modelled in theory. There is certainly need for further analysis of the measurements possibly supplemented by a new set of measurements. However, design rules already can be derived from the results obtained so far. A good sizing of the airchamber in relation to the stroke volume of the pump keeps the pressure fluctuations, and so the fluctuating hydrodynamic forces acting on the pump rod, within bounds. 13 refs.

  20. Natriuretic Hormones, Endogenous Ouabain, and Related Sodium Transport Inhibitors

    Directory of Open Access Journals (Sweden)

    John eHamlyn

    2014-12-01

    Full Text Available The work of deWardener and colleagues stimulated longstanding interest in natriuretic hormones (NH. In addition to the atrial peptides (APs, the circulation contains unidentified physiologically-relevant NHs. One NH is controlled by the central nervous system (CNS and likely secreted by the pituitary. Its circulating activity is modulated by salt intake and the prevailing sodium concentration of the blood and intracerebroventricular fluid, and contributes to postprandial and dehydration natriuresis. The other NH, mobilized by atrial stretch, promotes natriuresis by increasing the production of intrarenal dopamine and/or nitric oxide. Both NHs have short (<35 minutes circulating half lives, depress renotubular sodium transport, and neither requires the renal nerves. The search for NHs led to endogenous cardiotonic steroids (CTS including ouabain-, digoxin-, and bufadienolide-like materials. These CTS, given acutely in high nanomole to micromole amounts into the general or renal circulations, inhibit sodium pumps and are natriuretic. Among these CTS, only bufalin is cleared sufficiently rapidly to qualify for an NH-like role. Ouabain-like CTS are cleared slowly, and when given chronically in low daily nanomole amounts, promote sodium retention, augment arterial myogenic tone, reduce renal blood flow and glomerular filtration, suppress nitric oxide in the renal vasa recta, and increase sympathetic nerve activity and blood pressure. Moreover, lowering total body sodium raises circulating endogenous ouabain. Thus, ouabain-like CTS have physiological actions that, like aldosterone, support renal sodium retention and blood pressure. In conclusion, the mammalian circulation contains two non-AP NHs. Identification of the CNS NH should be a priority.

  1. [Intra-graft balloon pumping--a clinical case report].

    Science.gov (United States)

    Nagata, M; Tashiro, T; Tanaka, K; Haruta, Y; Todo, K

    1991-12-01

    A 29-year-old female underwent tube graft replacement of distal aortic arch and descending aorta for dissecting aneurysm. After 42 minutes of aortic cross-clamping the patient was initially weaned satisfactorily from cardiopulmonary bypass (CPB). However, cardiac arrhythmia and cardiac arrest necessitated reestablishment of CPB. Electro-cardiography showed inferior myocardial infarction. To wean CPB intraaortic balloon pumping (IABP) was mandatory. But because of dissecting aortic aneurysm IABP in conventional method was contra-indicated. Intra graft balloon pumping (IGBP) was initiated while the patient was on full CPB. A low-porosity woven Dacron tube graft (22 mm) was anastomosed end-to-side to ascending aorta. A balloon was inserted into the tube graft to establish IGBP. This IGBP provided effective circulatory assist. The patient was weaned from CPB 1 hours after reestablishment of IGBP. Postoperative course was stable. The patient was returned to the operating room for removal of the balloon 3 days postoperatively. We reported the case for whom IGBP was effective. IGBP was effective circulatory support for the patient when conventional use of IABP was contra-indicated. PMID:1774515

  2. Anesthesia for off-pump coronary artery bypass surgery

    Directory of Open Access Journals (Sweden)

    Thomas M Hemmerling

    2013-01-01

    Full Text Available The evolution of techniques and knowledge of beating heart surgery has led anesthesia toward the development of new procedures and innovations to promote patient safety and ensure high standards of care. Off-pump coronary artery bypass (OPCAB surgery has shown to have some advantages compared to on-pump cardiac surgery, particularly the reduction of postoperative complications including systemic inflammation, myocardial injury, and cerebral injury. Minimally invasive surgery for single vessel OPCAB through a limited thoracotomy incision can offer the advantage of further reduction of complications. The anesthesiologist has to deal with different issues, including hemodynamic instability and myocardial ischemia during aorto-coronary bypass grafting. The anesthesiologist and surgeon should collaborate and plan the best perioperative strategy to provide optimal care and ensure a rapid and complete recovery. The use of high thoracic epidural analgesia and fast-track anesthesia offers particular benefits in beating heart surgery. The excellent analgesia, the ability to reduce myocardial oxygen consumption, and the good hemodynamic stability make high thoracic epidural analgesia an interesting technique. New scenarios are entering in cardiac anesthesia: ultra-fast-track anesthesia with extubation in the operating room and awake surgery tend to be less invasive, but can only be performed on selected patients.

  3. Altered erythrocyte Na-K pump in anorectic patients

    International Nuclear Information System (INIS)

    The status of the erythrocyte sodium pump was evaluated in a group of patients suffering from anorexia nervosa and a group of healthy female control subjects. Anorectic patients showed significantly higher mean values of digoxin-binding sites/cell (ie, the number of Na-K-ATPase units) with respect to control subjects while no differences were found in the specific 86Rb uptake (which reflects the Na-K-ATPase activity) between the two groups. A significant correlation was found between relative weight and the number of Na-K-ATPase pump units (r = -0.66; P less than 0.0001). Anorectic patients showed lower serum T3 concentrations (71.3 +/- 53 ng/dL) with respect to control subjects (100.8 +/- 4.7 ng/dL; P less than 0.0005) and a significant negative correlation between T3 levels and the number of pump units (r = -0.52; P less than 0.003) was found. This study therefore shows that the erythrocyte Na-K pump may be altered in several anorectic patients. The authors suggest that this feature could be interrelated with the degree of underweight and/or malnutrition

  4. Altered erythrocyte Na-K pump in anorectic patients

    Energy Technology Data Exchange (ETDEWEB)

    Pasquali, R.; Strocchi, E.; Malini, P.; Casimirri, F.; Ambrosioni, E.; Melchionda, N.; Labo, G.

    1985-07-01

    The status of the erythrocyte sodium pump was evaluated in a group of patients suffering from anorexia nervosa and a group of healthy female control subjects. Anorectic patients showed significantly higher mean values of digoxin-binding sites/cell (ie, the number of Na-K-ATPase units) with respect to control subjects while no differences were found in the specific /sup 86/Rb uptake (which reflects the Na-K-ATPase activity) between the two groups. A significant correlation was found between relative weight and the number of Na-K-ATPase pump units (r = -0.66; P less than 0.0001). Anorectic patients showed lower serum T3 concentrations (71.3 +/- 53 ng/dL) with respect to control subjects (100.8 +/- 4.7 ng/dL; P less than 0.0005) and a significant negative correlation between T3 levels and the number of pump units (r = -0.52; P less than 0.003) was found. This study therefore shows that the erythrocyte Na-K pump may be altered in several anorectic patients. The authors suggest that this feature could be interrelated with the degree of underweight and/or malnutrition.

  5. On the multiple roles of the voltage gated sodium channel β1 subunit in genetic diseases

    Directory of Open Access Journals (Sweden)

    Debora eBaroni

    2015-05-01

    Full Text Available Voltage-gated sodium channels are intrinsic plasma membrane proteins that initiate the action potential in electrically excitable cells. They are composed of a pore-forming α-subunit and associated β-subunits. The β1-subunit was the first accessory subunit to be cloned. It can be important for controlling cell excitability and modulating multiple aspects of sodium channel physiology. Mutations of β1 are implicated in a wide variety of inherited pathologies, including epilepsy and cardiac conduction diseases. This review summarizes β1-subunit related channelopathies pointing out the current knowledge concerning their genetic background and their underlying molecular mechanisms.

  6. Robot-assisted cardiac surgery.

    Science.gov (United States)

    Ishikawa, Norihiko; Watanabe, Go

    2015-01-01

    Recognition of the significant advantages of minimizing surgical trauma has resulted in the development of minimally invasive surgical procedures. Endoscopic surgery offers patients the benefits of minimally invasive surgery, and surgical robots have enhanced the ability and precision of surgeons. Consequently, technological advances have facilitated totally endoscopic robotic cardiac surgery, which has allowed surgeons to operate endoscopically rather than through a median sternotomy during cardiac surgery. Thus, repairs for structural heart conditions, including mitral valve plasty, atrial septal defect closure, multivessel minimally invasive direct coronary artery bypass grafting (MIDCAB), and totally endoscopic coronary artery bypass graft surgery (CABG), can be totally endoscopic. Robot-assisted cardiac surgery as minimally invasive cardiac surgery is reviewed. PMID:26134073

  7. Recent developments in cardiac pacing.

    Science.gov (United States)

    Rodak, D J

    1995-10-01

    Indications for cardiac pacing continue to expand. Pacing to improve functional capacity, which is now common, relies on careful patient selection and technical improvements, such as complex software algorithms and diagnostic capabilities.

  8. Robotic Applications in Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    Alan P. Kypson

    2008-11-01

    Full Text Available Traditionally, cardiac surgery has been performed through a median sternotomy, which allows the surgeon generous access to the heart and surrounding great vessels. As a paradigm shift in the size and location of incisions occurs in cardiac surgery, new methods have been developed to allow the surgeon the same amount of dexterity and accessibility to the heart in confined spaces and in a less invasive manner. Initially, long instruments without pivot points were used, however, more recent robotic telemanipulation systems have been applied that allow for improved dexterity, enabling the surgeon to perform cardiac surgery from a distance not previously possible. In this rapidly evolving field, we review the recent history and clinical results of using robotics in cardiac surgery.

  9. Oleic and linoleic acids are active principles in Nigella sativa and stabilize an E2P conformation of the Na,K-ATPase. Fatty acids differentially regulate cardiac glycoside interaction with the pump

    DEFF Research Database (Denmark)

    Mahmmoud, Yasser Ahmed; Christensen, Søren Brøgger

    2011-01-01

    Nigella sativa seed oil was found to contain a modulator of Na,K-ATPase. Separation analyses combined with (1)H NMR and GCMS identified the inhibitory fraction as a mixture of oleic and linoleic acids. These two fatty acids are specifically concentrated in several medicinal plant oils, and have...... particularly been implicated in decreasing high blood pressure. The ouabain binding site on Na,K-ATPase has also been implicated in blood pressure regulation. Thus, we aimed to determine how these two molecules modify pig kidney Na,K-ATPase. Oleic and linoleic acids did not modify reactions involving the E(1......) (Na(+)) conformations of the Na,K-ATPase. In contrast, K(+) dependent reactions were strongly modified after treatment. Oleic and linoleic acids were found to stabilize a pump conformation that binds ouabain with high affinity, i.e., an ion free E(2)P form. Time-resolved binding assays using...

  10. Sodium-based hydrides for thermal energy applications

    Science.gov (United States)

    Sheppard, D. A.; Humphries, T. D.; Buckley, C. E.

    2016-04-01

    Concentrating solar-thermal power (CSP) with thermal energy storage (TES) represents an attractive alternative to conventional fossil fuels for base-load power generation. Sodium alanate (NaAlH4) is a well-known sodium-based complex metal hydride but, more recently, high-temperature sodium-based complex metal hydrides have been considered for TES. This review considers the current state of the art for NaH, NaMgH3- x F x , Na-based transition metal hydrides, NaBH4 and Na3AlH6 for TES and heat pumping applications. These metal hydrides have a number of advantages over other classes of heat storage materials such as high thermal energy storage capacity, low volume, relatively low cost and a wide range of operating temperatures (100 °C to more than 650 °C). Potential safety issues associated with the use of high-temperature sodium-based hydrides are also addressed.

  11. A kinetic description for sodium and potassium effects on (Na+ plus K+)-adenosine triphosphatase: a model for a two-nonequivalent site potassium activation and an analysis of multiequivalent site models for sodium activation.

    Science.gov (United States)

    Lindenmayer, G E; Schwartz, A; Thompson, H K

    1974-01-01

    5.35 mM sodium in the absence of potassium.6. Derivation of the model for sodium activation assumed that the affinities of these sites for sodium and potassium are independent of cation interactions with the potassium-activation sites. Therefore, the kinetic descriptions for sodium and potassium effects form a composite model that is consistent with simultaneous transport of sodium and potassium.7. Predictions of the composite equation are in reasonable agreement with data obtained by variation of sodium (potassium = 10 mM), variation of potassium (sodium = 100 mM) and by simultaneous variation of sodium and potassium (sodium:potassium = 10). Sodium-activation data (2.5-20 mM sodium) also agree with predictions of the model in the presence of potassium concentrations which are thought to be present at the sodium-activation sites in vivo.8. The kinetic description for sodium (three-equivalent sites) and potassium (two-nonequivalent sites) activation of the transport-ATPase is in accord with the probable stoichiometric requirements of the sodium pump. The model is also in general agreement with other studies on intact transporting systems and (Na(+)+K(+))-ATPase in fragmented membrane preparations with respect to potassium activation, although there is a quantitative disagreement. The model for sodium activation, though consistent with data obtained by other studies on fragmented (Na(+)+K(+))-ATPase preparations, is in apparent variance with much of the data obtained for intact transporting systems. The description for potassium activation suggests that the rates of ouabain binding to (Na(+)+K(+))-ATPase are modulated by competition between sodium and potassium for one of the two potassium-activation sites. PMID:4274214

  12. High Temperature Thermoacoustic Heat Pump

    Energy Technology Data Exchange (ETDEWEB)

    Tijani, H.; Spoelstra, S. [ECN Biomass and Energy Efficiency, Petten (Netherlands)

    2012-07-15

    Thermoacoustic technology can provide new types of heat pumps that can be deployed in different applications. Thermoacoustic heat pumps can for example be applied in dwellings to generate cooling or heating. Typically, space and water heating makes up about 60% of domestic and office energy consumption. The application of heat pumps can contribute to achieve energy savings and environmental benefits by reducing CO2 and NOx emissions. This paper presents the study of a laboratory scale thermoacoustic-Stirling heat pump operating between 10C and 80C which can be applied in domestics and offices. The heat pump is driven by a thermoacoustic-Stirling engine. The experimental results show that the heat pump pumps 250 W of heat at 60C at a drive ratio of 3.6 % and 200 W at 80C at a drive ratio of 3.5 %. The performance for both cases is about 40% of the Carnot performance. The design, construction, and performance measurements of the heat pump will be presented and discussed.

  13. Multi-path peristaltic pump

    Science.gov (United States)

    Chandler, Joseph A. (Inventor)

    1986-01-01

    The instant invention is directed to a peristaltic pump for critical laboratory or hospital applications requiring precise flow rates over an extended period of time. Within the cylindrical barrel pump housing is a single-piece, molded, elastometric, cylindrical liner with a multiplicity of flattened helical channels created therein from one end of the liner to the other. Three cylindrical rollers rotate about the center axis of the pump around the inside surface of the liner selectively compressing the liner, and hence the helical channels between the rollers and the barrel housing, creating a pumping action by forcing trapped fluid in the helical channels axially from one end of the liner to the opposite end. The novelty of the invention appears to lie in the provision of the special liner with multiple helical channels as the pumping chamber, rather than the standard single elastomeric tubing which is squeezed repeatedly by rollers to move the liquid through a typical peristaltic pump. Large, repeated deflections on the standard tubing causes a permanent set in the tubing, thus either changing the flow rate, or requiring a new section of tubing to be positioned in the pump head. Further, this configuration minimizes the amount of outflow pulsation which is characteristic of a typical single tubing peristaltic pump.

  14. Threshold values of autoresonant pumping

    OpenAIRE

    Kiselev, O. M.

    2013-01-01

    There exists stable growing solution of primary resonant equation for a autoresonant pumping with decreasing amplitude. The primary term of asymptotics is $O(\\sqrt{t})$ and does not depend on order of the force from some interval. We point to the interval for the amplitude of the pumping for which the growing stable solution exists.

  15. Centrifugal pumps for rocket engines

    Science.gov (United States)

    Campbell, W. E.; Farquhar, J.

    1974-01-01

    The use of centrifugal pumps for rocket engines is described in terms of general requirements of operational and planned systems. Hydrodynamic and mechanical design considerations and techniques and test procedures are summarized. Some of the pump development experiences, in terms of both problems and solutions, are highlighted.

  16. Ion-Pumping Microbial Rhodopsins

    Directory of Open Access Journals (Sweden)

    Hideki eKandori

    2015-09-01

    Full Text Available Rhodopsins are light-sensing proteins used in optogenetics. The word rhodopsin originates from the Greek words rhodo and opsis, indicating rose and sight, respectively. Although the classical meaning of rhodopsin is the red-colored pigment in our eyes, the modern meaning of rhodopsin encompasses photoactive proteins containing a retinal chromophore in animals and microbes. Animal and microbial rhodopsins possess 11-cis and all-trans retinal, respectively, to capture light in seven transmembrane α-helices, and photoisomerizations into all-trans and 13-cis forms, respectively, initiate each function. Ion-transporting proteins can be found in microbial rhodopsins, such as light-gated channels and light-driven pumps, which are the main tools in optogenetics. Light-driven pumps, such as archaeal H+ pump bacteriorhodopsin (BR and Cl- pump halorhodopsin (HR, were discovered in the 1970s, and their mechanism has been extensively studied. On the other hand, different kinds of H+ and Cl- pumps have been found in marine bacteria, such as proteorhodopsin (PR and Fulvimarina pelagi rhodopsin (FR, respectively. In addition, a light-driven Na+ pump was found, Krokinobacter eikastus rhodopsin 2 (KR2. These light-driven ion-pumping microbial rhodopsins are classified as DTD, TSA, DTE, NTQ and NDQ rhodopsins for BR, HR, PR, FR and KR2, respectively. Recent understanding of ion-pumping microbial rhodopsins is reviewed in this paper.

  17. Cardiac Biomarkers in Hyperthyroid Cats

    OpenAIRE

    Sangster, Jodi Kirsten

    2013-01-01

    Background: Hyperthyroidism has substantial effects on the circulatory system. The cardiac biomarkers NT-proBNP and troponin I (cTNI) have proven useful in identifying cats with myocardial disease but have not been as extensively investigated in hyperthyroidism.Hypothesis: Plasma NT-proBNP and cTNI concentrations are higher in cats with primary cardiac disease than in cats with hyperthyroidism and higher in cats with hyperthyroidism than in healthy control cats.Animals: Twenty-three hyperthyr...

  18. Cardiac manifestations in systemic sclerosis

    Institute of Scientific and Technical Information of China (English)

    Sevdalina; Lambova

    2014-01-01

    Primary cardiac involvement, which develops as a direct consequence of systemic sclerosis(SSc), may manifest as myocardial damage, fibrosis of the conduction system, pericardial and, less frequently, as valvular disease. In addition, cardiac complications in SSc may develop as a secondary phenomenon due to pulmonary arterial hypertension and kidney pathology. The prevalence of primary cardiac involvement in SSc is variable and difficult to determine because of the diversity of cardiac manifestations, the presence of subclinical periods, the type of diagnostic tools applied, and the diversity of patient populations. When clinically manifested, cardiac involvement is thought to be an important prognostic factor. Profound microvascular disease is a pathognomonic feature of SSc, as both vasospasm and structural alterations are present. Such alterations are thought to predict macrovascular atherosclerosis over time. There are contradictory reports regarding the prevalence of atherosclerosis in SSc. According to some authors, the prevalence of atherosclerosis of the large epicardial coronary arteries is similar to that of the general population, in contrast with other rheumatic diseases such as rheumatoid arthritis and systemic lupus erythematosus. However, the level of inflammation in SSc is inferior. Thus, the atherosclerotic process may not be as aggressive and not easily detectable in smaller studies. Echocardiography(especially tissue Doppler imaging), single-photon emission computed tomography, magnetic resonance imaging and cardiac computed tomography are sensitive techniques for earlier detection of both structural and functional scleroderma-related cardiac pathologies. Screening for subclinical cardiac involvement via modern, sensitive tools provides an opportunity for early diagnosis and treatment, which is of crucial importance for a positive outcome.

  19. Computational Modeling of Cardiac Electromechanics

    OpenAIRE

    Krishnamoorthi, Shankarjee

    2013-01-01

    Cardiac arrhythmias are a leading cause of death worldwide. Notably, the electrophysiologiy and microstructural requirements for a fatal ventricular arrhythmia remain incompletely understood, thereby the treatment remains largely empirical. Standard antiarrhythmic drug therapy has failed to reduce, and in some instances has increased, the incidence of Sudden Cardiac Death (SCD). Hence, a more complete understanding of the mechanisms that foment a fatal arrhythmia is needed and computational m...

  20. Current trends in cardiac rehabilitation

    OpenAIRE

    Dafoe, W; Huston, P

    1997-01-01

    Cardiac rehabilitation can reduce mortality and morbidity for patients with many types of cardiac disease cost-effectively, yet is generally underutilized. Rehabilitation is helpful not only for patients who have had a myocardial infarction but also for those with stable angina or congestive heart failure or those who have undergone myocardial revascularization procedures, a heart transplant or heart valve surgery. The beneficial effects of rehabilitation include a reduction in the rate of de...

  1. An overview of cardiac morphogenesis.

    OpenAIRE

    Schleich, Jean-Marc; Abdulla, Tariq; Summers, Ron; Houyel, Lucile

    2013-01-01

    International audience Accurate knowledge of normal cardiac development is essential for properly understanding the morphogenesis of congenital cardiac malformations that represent the most common congenital anomaly in newborns. The heart is the first organ to function during embryonic development and is fully formed at 8 weeks of gestation. Recent studies stemming from molecular genetics have allowed specification of the role of cellular precursors in the field of heart development. In th...

  2. SOLAR PUMPED LASER MICROTHRUSTER

    Energy Technology Data Exchange (ETDEWEB)

    Rubenchik, A M; Beach, R; Dawson, J; Siders, C W

    2010-02-05

    The development of microsatellites requires the development of engines to modify their orbit. It is natural to use solar energy to drive such engines. For an unlimited energy source the optimal thruster must use a minimal amount of expendable material to minimize launch costs. This requires the ejected material to have the maximal velocity and, hence, the ejected atoms must be as light as possible and be ejected by as high an energy density source as possible. Such a propulsion can be induced by pulses from an ultra-short laser. The ultra-short laser provides the high-energy concentration and high-ejected velocity. We suggest a microthruster system comprised of an inflatable solar concentrator, a solar panel, and a diode-pumped fiber laser. We will describe the system design and give weight estimates.

  3. Nanowire liquid pumps

    Science.gov (United States)

    Huang, Jian Yu; Lo, Yu-Chieh; Niu, Jun Jie; Kushima, Akihiro; Qian, Xiaofeng; Zhong, Li; Mao, Scott X.; Li, Ju

    2013-04-01

    The ability to form tiny droplets of liquids and control their movements is important in printing or patterning, chemical reactions and biological assays. So far, such nanofluidic capabilities have principally used components such as channels, nozzles or tubes, where a solid encloses the transported liquid. Here, we show that liquids can flow along the outer surface of solid nanowires at a scale of attolitres per second and the process can be directly imaged with in situ transmission electron microscopy. Microscopy videos show that an ionic liquid can be pumped along tin dioxide, silicon or zinc oxide nanowires as a thin precursor film or as beads riding on the precursor film. Theoretical analysis suggests there is a critical film thickness of ~10 nm below which the liquid flows as a flat film and above which it flows as discrete beads. This critical thickness is the result of intermolecular forces between solid and liquid, which compete with liquid surface energy and Rayleigh-Plateau instability.

  4. Electric fluid pump

    Science.gov (United States)

    Van Dam, Jeremy Daniel; Turnquist, Norman Arnold; Raminosoa, Tsarafidy; Shah, Manoj Ramprasad; Shen, Xiaochun

    2015-09-29

    An electric machine is presented. The electric machine includes a hollow rotor; and a stator disposed within the hollow rotor, the stator defining a flow channel. The hollow rotor includes a first end portion defining a fluid inlet, a second end portion defining a fluid outlet; the fluid inlet, the fluid outlet, and the flow channel of the stator being configured to allow passage of a fluid from the fluid inlet to the fluid outlet via the flow channel; and wherein the hollow rotor is characterized by a largest cross-sectional area of hollow rotor, and wherein the flow channel is characterized by a smallest cross-sectional area of the flow channel, wherein the smallest cross-sectional area of the flow channel is at least about 25% of the largest cross-sectional area of the hollow rotor. An electric fluid pump and a power generation system are also presented.

  5. Pump it up

    Science.gov (United States)

    Maffli, Luc; O'Brien, Benjamin; Rosset, Samuel; Shea, Herbert

    2012-04-01

    We report on the use of zipping actuation applied to dielectric elastomer actuators to microfabricate mm-sized pumps. The zipping actuators presented here use electrostatic attraction to deform an elastomeric membrane by pulling it into contact with a rigid counter electrode. We present several actuation schemes using either conventional DEA actuation, zipping, or a combination of both in order to realize microfluidic devices. A zipping design in which the electric field is applied across the elastomer membrane was explored theoretically and experimentally. Single zipping chambers and a micropump body made of a three chambers connected by an embedded channel were wet-etched into a silicon wafer and subsequently covered by a gold-implanted silicone membrane. We measured static deflections of up to 300 μm on chambers with square openings of 1.8 and 2.6 mm side, in very good agreement with our model.

  6. Techniques for extinguishing sodium fires

    International Nuclear Information System (INIS)

    The experimental work done to evaluate the performance of commercially available fire extinguishants and powders for sodium fires is described. Dry chemical powder with sodium bicarbonate base was found very effective. Another effective method of extinghishing fire by using perforated covered tray is also discussed. (auth.)

  7. Stochastic thermodynamics of hidden pumps

    Science.gov (United States)

    Esposito, Massimiliano; Parrondo, Juan M. R.

    2015-05-01

    We show that a reversible pumping mechanism operating between two states of a kinetic network can give rise to Poisson transitions between these two states. An external observer, for whom the pumping mechanism is not accessible, will observe a Markov chain satisfying local detailed balance with an emerging effective force induced by the hidden pump. Due to the reversibility of the pump, the actual entropy production turns out to be lower than the coarse-grained entropy production estimated from the flows and affinities of the resulting Markov chain. Moreover, in presence of a large time scale separation between the fast-pumping dynamics and the slow-network dynamics, a finite current with zero dissipation may be produced. We make use of these general results to build a synthetase-like kinetic scheme able to reversibly produce high free-energy molecules at a finite rate and a rotatory motor achieving 100% efficiency at finite speed.

  8. Cardiac Optogenetics: Enhancement by All-trans-Retinal.

    Science.gov (United States)

    Yu, Jinzhu; Chen, Kay; Lucero, Rachel V; Ambrosi, Christina M; Entcheva, Emilia

    2015-11-16

    All-trans-Retinal (ATR) is a photosensitizer, serving as the chromophore for depolarizing and hyperpolarizing light-sensitive ion channels and pumps (opsins), recently employed as fast optical actuators. In mammalian optogenetic applications (in brain and heart), endogenous ATR availability is not considered a limiting factor, yet it is unclear how ATR modulation may affect the response to optical stimulation. We hypothesized that exogenous ATR may improve light responsiveness of cardiac cells modified by Channelrhodopsin2 (ChR2), hence lowering the optical pacing energy. In virally-transduced (Ad-ChR2(H134R)-eYFP) light-sensitive cardiac syncytium in vitro, ATR supplements ≤2 μM improved cardiomyocyte viability and augmented ChR2 membrane expression several-fold, while >4 μM was toxic. Employing integrated optical actuation (470 nm) and optical mapping, we found that 1-2 μM ATR dramatically reduced optical pacing energy (over 30 times) to several μW/mm(2), lowest values reported to date, but also caused action potential prolongation, minor changes in calcium transients and no change in conduction. Theoretical analysis helped explain ATR-caused reduction of optical excitation threshold in cardiomyocytes. We conclude that cardiomyocytes operate at non-saturating retinal levels, and carefully-dosed exogenous ATR can enhance the performance of ChR2 in cardiac cells and yield energy benefits over orders of magnitude for optogenetic stimulation.

  9. FGF21 and cardiac physiopathology

    Directory of Open Access Journals (Sweden)

    Anna ePlanavila

    2015-08-01

    Full Text Available The heart is not traditionally considered either a target or a site of fibroblast growth factor-21 (FGF21 production. However, recent findings indicate that FGF21 can act as a cardiomyokine; that is, it is produced by cardiac cells at significant levels and acts in an autocrine manner on the heart itself. The heart is sensitive to the effects of FGF21, both systemic and locally generated, owing to the expression in cardiomyocytes of β-Klotho, the key co-receptor known to confer specific responsiveness to FGF21 action. FGF21 has been demonstrated to protect against cardiac hypertrophy, cardiac inflammation, and oxidative stress. FGF21 expression in the heart is induced in response to cardiac insults, such as experimental cardiac hypertrophy and myocardial infarction in rodents, as well as in failing human hearts. Intracellular mechanisms involving PPARα and Sirt1 mediate transcriptional regulation of the FGF21 gene in response to exogenous stimuli. In humans, circulating FGF21 levels are elevated in coronary heart disease and atherosclerosis, and are associated with a higher risk of cardiovascular events in patients with type 2 diabetes. These findings provide new insights into the role of FGF21 in the heart and may offer potential therapeutic strategies for cardiac disease.

  10. [Stem cells and cardiac regeneration].

    Science.gov (United States)

    Perez Millan, Maria Ines; Lorenti, Alicia

    2006-01-01

    Stem cells are defined by virtue of their functional attributes: absence of tissue specific differentitated markers, capable of proliferation, able to self-maintain the population, able to produce a large number of differentiated, functional progeny, able to regenerate the tissue after injury. Cell therapy is an alternative for the treatment of several diseases, like cardiac diseases (cell cardiomyoplasty). A variety of stem cells could be used for cardiac repair: from cardiac and extracardiac sources. Each cell type has its own profile of advantages, limitations, and practicability issues in specific clinical settings. Differentiation of bone marrow stem cells to cardiomyocyte-like cells have been observed under different culture conditions. The presence of resident cardiac stem cell population capable of differentiation into cardiomyocyte or vascular lineage suggests that these cells could be used for cardiac tissue repair, and represent a great promise for clinical application. Stem cells mobilization by cytokines may also offer a strategy for cardiac regeneration. The use of stem cells (embryonic and adult) may hold the key to replacing cells lost in many devastating diseases. This potential benefit is a major focus for stem cell research.

  11. Cardiac Regeneration and Stem Cells.

    Science.gov (United States)

    Zhang, Yiqiang; Mignone, John; MacLellan, W Robb

    2015-10-01

    After decades of believing the heart loses the ability to regenerate soon after birth, numerous studies are now reporting that the adult heart may indeed be capable of regeneration, although the magnitude of new cardiac myocyte formation varies greatly. While this debate has energized the field of cardiac regeneration and led to a dramatic increase in our understanding of cardiac growth and repair, it has left much confusion in the field as to the prospects of regenerating the heart. Studies applying modern techniques of genetic lineage tracing and carbon-14 dating have begun to establish limits on the amount of endogenous regeneration after cardiac injury, but the underlying cellular mechanisms of this regeneration remained unclear. These same studies have also revealed an astonishing capacity for cardiac repair early in life that is largely lost with adult differentiation and maturation. Regardless, this renewed focus on cardiac regeneration as a therapeutic goal holds great promise as a novel strategy to address the leading cause of death in the developed world.

  12. Cardiac involvement in myotonic dystrophy

    DEFF Research Database (Denmark)

    Lund, Marie; Diaz, Lars Jorge; Ranthe, Mattis Flyvholm;

    2014-01-01

    genetic testing for DM1. Information on incident cardiac diseases was obtained from the NPR. We estimated standardized incidence ratios (SIRs) of cardiac disease compared with the background population, overall and according to selected diagnostic subgroups (cardiomyopathy, heart failure, conduction...... disorders, arrhythmias, and device implantation). In the DM cohort, SIR for any cardiac disease was 3.42 [95% confidence interval (CI) 3.01-3.86]; for a cardiac disease belonging to the selected subgroups 6.91 (95% CI: 5.93-8.01) and for other cardiac disease 2.59 (95% CI: 2.03-3.25). For a cardiac disease...... belonging to the selected subgroups, the risk was particularly high in the first year after DM diagnosis [SIR 15.4 (95% CI: 10.9-21.3)] but remained significantly elevated in subsequent years [SIR 6.07 (95% CI: 5.11-7.16]). The risk was higher in young cohort members [e.g. 20-39 years: SIR 18.1 (95% CI: 12...

  13. Cardiac imaging. A multimodality approach

    Energy Technology Data Exchange (ETDEWEB)

    Thelen, Manfred [Johannes Gutenberg University Hospital, Mainz (Germany); Erbel, Raimund [University Hospital Essen (Germany). Dept. of Cardiology; Kreitner, Karl-Friedrich [Johannes Gutenberg University Hospital, Mainz (Germany). Clinic and Polyclinic for Diagnostic and Interventional Radiology; Barkhausen, Joerg (eds.) [University Hospital Schleswig-Holstein, Luebeck (Germany). Dept. of Radiology and Nuclear Medicine

    2009-07-01

    An excellent atlas on modern diagnostic imaging of the heart Written by an interdisciplinary team of experts, Cardiac Imaging: A Multimodality Approach features an in-depth introduction to all current imaging modalities for the diagnostic assessment of the heart as well as a clinical overview of cardiac diseases and main indications for cardiac imaging. With a particular emphasis on CT and MRI, the first part of the atlas also covers conventional radiography, echocardiography, angiography and nuclear medicine imaging. Leading specialists demonstrate the latest advances in the field, and compare the strengths and weaknesses of each modality. The book's second part features clinical chapters on heart defects, endocarditis, coronary heart disease, cardiomyopathies, myocarditis, cardiac tumors, pericardial diseases, pulmonary vascular diseases, and diseases of the thoracic aorta. The authors address anatomy, pathophysiology, and clinical features, and evaluate the various diagnostic options. Key features: - Highly regarded experts in cardiology and radiology off er image-based teaching of the latest techniques - Readers learn how to decide which modality to use for which indication - Visually highlighted tables and essential points allow for easy navigation through the text - More than 600 outstanding images show up-to-date technology and current imaging protocols Cardiac Imaging: A Multimodality Approach is a must-have desk reference for cardiologists and radiologists in practice, as well as a study guide for residents in both fields. It will also appeal to cardiac surgeons, general practitioners, and medical physicists with a special interest in imaging of the heart. (orig.)

  14. Comparison of the standard roller pump and a pulsatile centrifugal pump for extracorporeal circulation during routine coronary artery bypass grafting.

    Science.gov (United States)

    Driessen, J J; Fransen, G; Rondelez, L; Schelstraete, E; Gevaert, L

    1991-01-01

    The present prospective study compared the standard nonpulsatile twin roller pump with the Sarns centrifugal pump, in the pulsatile mode, as arterial pumps for extracorporeal circulation during coronary artery bypass grafting (CABG). The study was conducted in two consecutive groups of 25 patients receiving a standard anaesthetic and surgical protocol. The investigated parameters included haemodynamic profiles, oxygen exchange, blood gas and acid-base homeostasis, haematology, coagulation and complement consumption. With comparable settings for pump flow, gas flow and delivered oxygen concentrations, there was no difference between the groups in the main haemodynamic parameters during cardiopulmonary bypass (CPB). However, a tenfold lower dose of sodium nitroprusside was required to keep systemic vascular resistance within physiologic limits during CPB in the centrifugal group (C group) compared with the roller group (R group). During rewarming oxygen extraction was higher in the C group than in the R group. During the first eight hours after CPB no differences in haemodynamics, oxygenation parameters and pulmonary shunt between the groups were observed. During, as well as after, CPB there was no significant difference in blood gas and acid-base homeostasis between either group. Average postoperative blood loss via chest tubes, total transfusions of blood products, haemoglobin and coagulation did not differ between the two groups. However, the white blood cell count, corrected for changes in haematocrit, decreased during the early phase of CPB in the R group, but not in the C group.(ABSTRACT TRUNCATED AT 250 WORDS)

  15. Heat pumps in industry. Pt. 2: Applications

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R.M. [Padova Univ., Vicenza (Italy). Ist. di Ingegneria Gestionale

    1995-04-01

    A selection of applications of heat pumps in industry is described, reporting plant lay-outs and performances. The selection includes compression heat pumps at different temperatures, vapour recompression systems, absorption heat pumps and heat transformers. (author)

  16. Results of treatment of congenital coronary artery fistulae in combination with cardiac arrhythmias

    Directory of Open Access Journals (Sweden)

    Bockeria L.A.

    2013-03-01

    and quality of life. Coronary angiography and computed tomography are the main diagnostic methods allowing to examine CAF. Hemodynamically non-compromised CAF coincided with CA require a follow-up and, if necessary, surgical and/or medical therapy of CA. Main indications for embolization are proximal location and single CAF. Indications for surgical on-pump repair are concomitant cardiac pathology and relatively large and wide CAF.

  17. Risk factors and the effect of cardiac resynchronization therapy on cardiac and non-cardiac mortality in MADIT-CRT

    DEFF Research Database (Denmark)

    Perkiomaki, Juha S; Ruwald, Anne-Christine; Kutyifa, Valentina;

    2015-01-01

    causes, 108 (63.9%) deemed cardiac, and 61 (36.1%) non-cardiac. In multivariate analysis, increased baseline creatinine was significantly associated with both cardiac and non-cardiac deaths [hazard ratio (HR) 2.97, P ...AIMS: To understand modes of death and factors associated with the risk for cardiac and non-cardiac deaths in patients with cardiac resynchronization therapy with implantable cardioverter-defibrillator (CRT-D) vs. implantable cardioverter-defibrillator (ICD) therapy, which may help clarify...... the action and limitations of cardiac resynchronization therapy (CRT) in relieving myocardial dysfunction. METHODS AND RESULTS: In Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT), during 4 years of follow-up, 169 (9.3%) of 1820 patients died of known...

  18. Sodium ionization detector and sensor

    International Nuclear Information System (INIS)

    Work conducted on a basic technology development effort with the Westinghouse Sodium Ionization Detector (SID) sensor is reported. Included are results obtained for three task areas: (1) On-line operational response testing - in-situ calibration techniques; (2) Performance-reliability characteristics of aged filaments; and (3) Evaluation of chemical interference effects. The results showed that a calibrator filament coated with a sodium compound, when activated, does supply the necessary sodium atoms to provide a valid operational in-situ test. The life time of new Cr203-protected SID sensor filaments can be extended by operating at a reduced temperature. However, there also is a reduction in the sensitivity. Non-sodium species, such as products from a smoldering fire and organic aerosols, produce an interference response from the sensor comparable to a typical sodium response

  19. Leak detector of liquid sodium

    International Nuclear Information System (INIS)

    Object: To arrange a cable core connected to a leakage current detector on the outer wall of piping for liquid sodium, devices or the like and apply a voltage to said core and outer wall to quickly and securely detect the leakage of liquid sodium. Structure: A cable, which is composed of metal coating formed of metal material (copper, steel, stainless, etc.) which is apt to be corroded by reaction products of liquid sodium with water and oxygen in air, and metal oxide (such as magnesium oxide, beryllium oxide, aluminum oxide) as an electric insulator is arranged on the outer wall of pipes or devices. In the event sodium is leaked from the pipes or devices, said metal coating and the insulator are corroded, and the leakage of sodium is sensed by a leakage current detector through the core in the cable. (Kamimura, M.)

  20. 40 CFR 415.170 - Applicability; description of the sodium dichromate and sodium sulfate production subcategory.

    Science.gov (United States)

    2010-07-01

    ... sodium dichromate and sodium sulfate production subcategory. 415.170 Section 415.170 Protection of... MANUFACTURING POINT SOURCE CATEGORY Sodium Dichromate and Sodium Sulfate Production Subcategory § 415.170 Applicability; description of the sodium dichromate and sodium sulfate production subcategory. The provisions...