  1. Cardiac sympathetic neuronal imaging using PET

    International Nuclear Information System (INIS)

    Lautamaeki, Riikka; Tipre, Dnyanesh; Bengel, Frank M.

    2007-01-01

    Balance of the autonomic nervous system is essential for adequate cardiac performance, and alterations seem to play a key role in the development and progression of various cardiac diseases. PET imaging of the cardiac autonomic nervous system has advanced extensively in recent years, and multiple pre- and postsynaptic tracers have been introduced. The high spatial and temporal resolution of PET enables noninvasive quantification of neurophysiologic processes at the tissue level. Ligands for catecholamine receptors, along with radiolabeled catecholamines and catecholamine analogs, have been applied to determine involvement of sympathetic dysinnervation at different stages of heart diseases such as ischemia, heart failure, and arrhythmia. This review summarizes the recent findings in neurocardiological PET imaging. Experimental studies with several radioligands and clinical findings in cardiac dysautonomias are discussed. (orig.)

  2. Respiratory and cardiac motion correction in dual gated PET/MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fayad, Hadi; Monnier, Florian [LaTIM, INSERM, UMR 1101, Brest (France); Odille, Freedy; Felblinger, Jacques [INSERM U947, University of Nancy, Nancy (France); Lamare, Frederic [INCIA, UMR5287, CNRS, CHU Bordeaux, Bordeaux (France); Visvikis, Dimitris [LaTIM, INSERM, UMR 1101, Brest (France)

    2015-05-18

    Respiratory and cardiac motion in PET/MR imaging leads to reduced quantitative and qualitative image accuracy. Correction methodologies involve the use of double gated acquisitions which lead to low signal-to-noise ratio (SNR) and to issues concerning the combination of cardiac and respiratory frames. The objective of this work is to use a generalized reconstruction by inversion of coupled systems (GRICS) approach, previously used for PET/MR respiratory motion correction, combined with a cardiac phase signal and a reconstruction incorporated PET motion correction approach in order to reconstruct motion free images from dual gated PET acquisitions. The GRICS method consists of formulating parallel MRI in the presence of patient motion as a coupled inverse problem. Its resolution, using a fixed-point method, allows the reconstructed image to be improved using a motion model constructed from the raw MR data and two respiratory belts. GRICS obtained respiratory displacements are interpolated using the cardiac phase derived from an ECG to model simultaneous cardiac and respiratory motion. Three different volunteer datasets (4DMR acquisitions) were used for evaluation. GATE was used to simulate 4DPET datasets corresponding to the acquired 4DMR images. Simulated data were subsequently binned using 16 cardiac phases (M1) vs diastole only (M2), in combination with 8 respiratory amplitude gates. Respiratory and cardiac motion corrected PET images using either M1 or M2 were compared to respiratory only corrected images and evaluated in terms of SNR and contrast improvement. Significant visual improvements were obtained when correcting simultaneously for respiratory and cardiac motion (using 16 cardiac phase or diastole only) compared to respiratory motion only compensation. Results were confirmed by an associated increased SNR and contrast. Results indicate that using GRICS is an efficient tool for respiratory and cardiac motion correction in dual gated PET/MR imaging.

  3. Evaluation of respiratory and cardiac motion correction schemes in dual gated PET/CT cardiac imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lamare, F., E-mail: frederic.lamare@chu-bordeaux.fr; Fernandez, P. [Univ. Bordeaux, INCIA, UMR 5287, F-33400 Talence (France); CNRS, INCIA, UMR 5287, F-33400 Talence (France); Service de Médecine Nucléaire, Hôpital Pellegrin, CHU de Bordeaux, 33076 Bordeaux (France); Le Maitre, A.; Visvikis, D. [INSERM, UMR1101, LaTIM, Université de Bretagne Occidentale, 29609 Brest (France); Dawood, M.; Schäfers, K. P. [European Institute for Molecular Imaging, University of Münster, Mendelstr. 11, 48149 Münster (Germany); Rimoldi, O. E. [Vita-Salute University and Scientific Institute San Raffaele, Milan, Italy and CNR Istituto di Bioimmagini e Fisiologia Molecolare, Milan (Italy)

    2014-07-15

    Purpose: Cardiac imaging suffers from both respiratory and cardiac motion. One of the proposed solutions involves double gated acquisitions. Although such an approach may lead to both respiratory and cardiac motion compensation there are issues associated with (a) the combination of data from cardiac and respiratory motion bins, and (b) poor statistical quality images as a result of using only part of the acquired data. The main objective of this work was to evaluate different schemes of combining binned data in order to identify the best strategy to reconstruct motion free cardiac images from dual gated positron emission tomography (PET) acquisitions. Methods: A digital phantom study as well as seven human studies were used in this evaluation. PET data were acquired in list mode (LM). A real-time position management system and an electrocardiogram device were used to provide the respiratory and cardiac motion triggers registered within the LM file. Acquired data were subsequently binned considering four and six cardiac gates, or the diastole only in combination with eight respiratory amplitude gates. PET images were corrected for attenuation, but no randoms nor scatter corrections were included. Reconstructed images from each of the bins considered above were subsequently used in combination with an affine or an elastic registration algorithm to derive transformation parameters allowing the combination of all acquired data in a particular position in the cardiac and respiratory cycles. Images were assessed in terms of signal-to-noise ratio (SNR), contrast, image profile, coefficient-of-variation (COV), and relative difference of the recovered activity concentration. Results: Regardless of the considered motion compensation strategy, the nonrigid motion model performed better than the affine model, leading to higher SNR and contrast combined with a lower COV. Nevertheless, when compensating for respiration only, no statistically significant differences were

  4. Bayesian Penalized Likelihood Image Reconstruction (Q.Clear) in 82Rb Cardiac PET: Impact of Count Statistics

    DEFF Research Database (Denmark)

    Christensen, Nana Louise; Tolbod, Lars Poulsen

    PET scans. 3) Static and dynamic images from a set of 7 patients (BSA: 1.6-2.2 m2) referred for 82Rb cardiac PET was analyzed using a range of beta factors. Results were compared to the institution’s standard clinical practice reconstruction protocol. All scans were performed on GE DMI Digital......Aim: Q.Clear reconstruction is expected to improve detection of perfusion defects in cardiac PET due to the high degree of image convergence and effective noise suppression. However, 82Rb (T½=76s) possess a special problem, since count statistics vary significantly not only between patients...... statistics using a cardiac PET phantom as well as a selection of clinical patients referred for 82Rb cardiac PET. Methods: The study consistent of 3 parts: 1) A thorax-cardiac phantom was scanned for 10 minutes after injection of 1110 MBq 82Rb. Frames at 3 different times after infusion were reconstructed...

  5. Quantitative simultaneous PET-MR imaging

    Science.gov (United States)

    Ouyang, Jinsong; Petibon, Yoann; Huang, Chuan; Reese, Timothy G.; Kolnick, Aleksandra L.; El Fakhri, Georges

    2014-06-01

    Whole-body PET is currently limited by the degradation due to patient motion. Respiratory motion degrades imaging studies of the abdomen. Similarly, both respiratory and cardiac motions significantly hamper the assessment of myocardial ischemia and/or metabolism in perfusion and viability cardiac PET studies. Based on simultaneous PET-MR, we have developed robust and accurate MRI methods allowing the tracking and measurement of both respiratory and cardiac motions during abdominal or cardiac studies. Our list-mode iterative PET reconstruction framework incorporates the measured motion fields into PET emission system matrix as well as the time-dependent PET attenuation map and the position dependent point spread function. Our method significantly enhances the PET image quality as compared to conventional methods.

  6. New horizons in cardiac innervation imaging. Introduction of novel 18F-labeled PET tracers

    International Nuclear Information System (INIS)

    Kobayashi, Ryohei; Chen, Xinyu; Werner, Rudolf A.; Lapa, Constantin; Javadi, Mehrbod S.; Higuchi, Takahiro

    2017-01-01

    Cardiac sympathetic nervous activity can be uniquely visualized by non-invasive radionuclide imaging techniques due to the fast growing and widespread application of nuclear cardiology in the last few years. The norepinephrine analogue 123 I-meta-iodobenzylguanidine ( 123 I-MIBG) is a single photon emission computed tomography (SPECT) tracer for the clinical implementation of sympathetic nervous imaging for both diagnosis and prognosis of heart failure. Meanwhile, positron emission tomography (PET) imaging has become increasingly attractive because of its higher spatial and temporal resolution compared to SPECT, which allows regional functional and dynamic kinetic analysis. Nevertheless, wider use of cardiac sympathetic nervous PET imaging is still limited mainly due to the demand of costly on-site cyclotrons, which are required for the production of conventional 11 C-labeled (radiological half-life, 20 min) PET tracers. Most recently, more promising 18 F-labeled (half-life, 110 min) PET radiopharmaceuticals targeting sympathetic nervous system have been introduced. These tracers optimize PET imaging and, by using delivery networks, cost less to produce. In this article, the latest advances of sympathetic nervous imaging using 18 F-labeled radiotracers along with their possible applications are reviewed. (orig.)

  7. Evaluation of attenuation correction in cardiac PET using PET/MR.

    Science.gov (United States)

    Lau, Jeffrey M C; Laforest, R; Sotoudeh, H; Nie, X; Sharma, S; McConathy, J; Novak, E; Priatna, A; Gropler, R J; Woodard, P K

    2017-06-01

    Simultaneous acquisition Positron emission tomography/magnetic resonance (PET/MR) is a new technology that has potential as a tool both in research and clinical diagnosis. However, cardiac PET acquisition has not yet been validated using MR imaging for attenuation correction (AC). The goal of this study is to evaluate the feasibility of PET imaging using a standard 2-point Dixon volume interpolated breathhold examination (VIBE) MR sequence for AC. Evaluation was performed in both phantom and patient data. A chest phantom containing heart, lungs, and a lesion insert was scanned by both PET/MR and PET/CT. In addition, 30 patients underwent whole-body 18 F-fluorodeoxyglucose PET/CT followed by simultaneous cardiac PET/MR. Phantom study showed 3% reduction of activity values in the myocardium due to the non-inclusion of the phased array coil in the AC. In patient scans, average standardized uptake values (SUVs) obtained by PET/CT and PET/MR showed no significant difference (n = 30, 4.6 ± 3.5 vs 4.7 ± 2.8, P = 0.47). There was excellent per patient correlation between the values acquired by PET/CT and PET/MR (R 2  = 0.97). Myocardial SUVs PET imaging using MR for AC shows excellent correlation with myocardial SUVs obtained by standard PET/CT imaging. The 2-point Dixon VIBE MR technique can be used for AC in simultaneous PET/MR data acquisition.

  8. TU-G-BRA-08: BEST IN PHYSICS (JOINT IMAGING-THERAPY): Hybrid PET-MRI Imaging of Acute Radiation Induced Cardiac Toxicity

    International Nuclear Information System (INIS)

    El-Sherif, O; Xhaferllari, I; Gaede, S; Sykes, J; Butler, J; Wisenberg, G; Prato, F

    2015-01-01

    Purpose: To identify the presence of low-dose radiation induced cardiac toxicity in a canine model using hybrid positron emission tomography (PET) and magnetic resonance imaging (MRI). Methods: Research ethics board approval was obtained for a longitudinal imaging study of 5 canines after cardiac irradiation. Animals were imaged at baseline, 1 week post cardiac irradiation, and 1 month post cardiac irradiation using a hybrid PET- MRI system (Biograph mMR, Siemens Healthcare). The imaging protocol was designed to assess acute changes in myocardial perfusion and inflammation. Myocardial perfusion imaging was performed using N13-ammonia tracer followed by a dynamic PET acquisition scan. A compartmental tracer kinetic model was used for absolute perfusion quantification. Myocardial inflammation imaging was performed using F18-fluorodeoxyglucose (FDG) tracer. The standard uptake value (SUV) over a region encompassing the whole heart was used to compare FDG scans. All animals received a simulation CT scan (GE Medical Systems) for radiation treatment planning. Radiation treatment plans were created using the Pinncale3 treatment planning system (Philips Radiation Oncology Systems) and designed to resemble the typical cardiac exposure during left-sided breast cancer radiotherapy. Cardiac irradiations were performed in a single fraction using a TrueBeam linear accelerator (Varian Medical Systems). Results: The delivered dose (mean ± standard deviation) to heart was 1.8±0.2 Gy. Reductions in myocardial stress perfusion relative to baseline were observed in 2 of the 5 animals 1 month post radiation. A global inflammatory response 1 month post radiation was observed in 4 of the 5 animals. The calculated SUV at 1 month post radiation was significantly higher (p=0.05) than the baseline SUV. Conclusion: Low doses of cardiac irradiation (< 2 Gy) may lead to myocardial perfusion defects and a global inflammatory response that can be detectable as early as 1 month post irradiation

  9. TU-G-BRA-08: BEST IN PHYSICS (JOINT IMAGING-THERAPY): Hybrid PET-MRI Imaging of Acute Radiation Induced Cardiac Toxicity

    Energy Technology Data Exchange (ETDEWEB)

    El-Sherif, O; Xhaferllari, I; Gaede, S [Western Univeristy, London, ON (United Kingdom); London Regional Cancer Program, London, ON (United Kingdom); Sykes, J; Butler, J [Lawson Health Research Institute, London, ON (United Kingdom); Wisenberg, G; Prato, F [Western Univeristy, London, ON (United Kingdom); Lawson Health Research Institute, London, ON (United Kingdom)

    2015-06-15

    Purpose: To identify the presence of low-dose radiation induced cardiac toxicity in a canine model using hybrid positron emission tomography (PET) and magnetic resonance imaging (MRI). Methods: Research ethics board approval was obtained for a longitudinal imaging study of 5 canines after cardiac irradiation. Animals were imaged at baseline, 1 week post cardiac irradiation, and 1 month post cardiac irradiation using a hybrid PET- MRI system (Biograph mMR, Siemens Healthcare). The imaging protocol was designed to assess acute changes in myocardial perfusion and inflammation. Myocardial perfusion imaging was performed using N13-ammonia tracer followed by a dynamic PET acquisition scan. A compartmental tracer kinetic model was used for absolute perfusion quantification. Myocardial inflammation imaging was performed using F18-fluorodeoxyglucose (FDG) tracer. The standard uptake value (SUV) over a region encompassing the whole heart was used to compare FDG scans. All animals received a simulation CT scan (GE Medical Systems) for radiation treatment planning. Radiation treatment plans were created using the Pinncale3 treatment planning system (Philips Radiation Oncology Systems) and designed to resemble the typical cardiac exposure during left-sided breast cancer radiotherapy. Cardiac irradiations were performed in a single fraction using a TrueBeam linear accelerator (Varian Medical Systems). Results: The delivered dose (mean ± standard deviation) to heart was 1.8±0.2 Gy. Reductions in myocardial stress perfusion relative to baseline were observed in 2 of the 5 animals 1 month post radiation. A global inflammatory response 1 month post radiation was observed in 4 of the 5 animals. The calculated SUV at 1 month post radiation was significantly higher (p=0.05) than the baseline SUV. Conclusion: Low doses of cardiac irradiation (< 2 Gy) may lead to myocardial perfusion defects and a global inflammatory response that can be detectable as early as 1 month post irradiation

  10. New cardiac cameras: single-photon emission CT and PET.

    Science.gov (United States)

    Slomka, Piotr J; Berman, Daniel S; Germano, Guido

    2014-07-01

    Nuclear cardiology instrumentation has evolved significantly in the recent years. Concerns about radiation dose and long acquisition times have propelled developments of dedicated high-efficiency cardiac SPECT scanners. Novel collimator designs, such as multipinhole or locally focusing collimators arranged in geometries that are optimized for cardiac imaging, have been implemented to enhance photon-detection sensitivity. Some of these new SPECT scanners use solid-state photon detectors instead of photomultipliers to improve image quality and to reduce the scanner footprint. These new SPECT devices allow dramatic up to 7-fold reduction in acquisition times or similar reduction in radiation dose. In addition, new hardware for photon attenuation correction allowing ultralow radiation doses has been offered by some vendors. To mitigate photon attenuation artifacts for the new SPECT scanners not equipped with attenuation correction hardware, 2-position (upright-supine or prone-supine) imaging has been proposed. PET hardware developments have been primarily driven by the requirements of oncologic imaging, but cardiac imaging can benefit from improved PET image quality and improved sensitivity of 3D systems. The time-of-flight reconstruction combined with resolution recovery techniques is now implemented by all major PET vendors. These new methods improve image contrast and image resolution and reduce image noise. High-sensitivity 3D PET without interplane septa allows reduced radiation dose for cardiac perfusion imaging. Simultaneous PET/MR hybrid system has been developed. Solid-state PET detectors with avalanche photodiodes or digital silicon photomultipliers have been introduced, and they offer improved imaging characteristics and reduced sensitivity to electromagnetic MR fields. Higher maximum count rate of the new PET detectors allows routine first-pass Rb-82 imaging, with 3D PET acquisition enabling clinical utilization of dynamic imaging with myocardial flow

  11. New horizons in cardiac innervation imaging. Introduction of novel {sup 18}F-labeled PET tracers

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Ryohei [University Hospital of Wuerzburg, Department of Nuclear Medicine, Wuerzburg (Germany); Nihon Medi-Physics Co., Ltd., Research Centre, Chiba (Japan); Chen, Xinyu [University Hospital of Wuerzburg, Department of Nuclear Medicine, Wuerzburg (Germany); University Hospital of Wuerzburg, Comprehensive Heart Failure Center, Wuerzburg (Germany); Werner, Rudolf A. [University Hospital of Wuerzburg, Department of Nuclear Medicine, Wuerzburg (Germany); University Hospital of Wuerzburg, Comprehensive Heart Failure Center, Wuerzburg (Germany); Johns Hopkins School of Medicine, The Russell H Morgan Department of Radiology and Radiological Sciences, Baltimore, MD (United States); Lapa, Constantin [University Hospital of Wuerzburg, Department of Nuclear Medicine, Wuerzburg (Germany); Javadi, Mehrbod S. [Johns Hopkins School of Medicine, The Russell H Morgan Department of Radiology and Radiological Sciences, Baltimore, MD (United States); Higuchi, Takahiro [University Hospital of Wuerzburg, Department of Nuclear Medicine, Wuerzburg (Germany); University Hospital of Wuerzburg, Comprehensive Heart Failure Center, Wuerzburg (Germany); National Cerebral and Cardiovascular Center, Department of Biomedical Imaging, Research Institute, Suita (Japan)

    2017-12-15

    Cardiac sympathetic nervous activity can be uniquely visualized by non-invasive radionuclide imaging techniques due to the fast growing and widespread application of nuclear cardiology in the last few years. The norepinephrine analogue {sup 123}I-meta-iodobenzylguanidine ({sup 123}I-MIBG) is a single photon emission computed tomography (SPECT) tracer for the clinical implementation of sympathetic nervous imaging for both diagnosis and prognosis of heart failure. Meanwhile, positron emission tomography (PET) imaging has become increasingly attractive because of its higher spatial and temporal resolution compared to SPECT, which allows regional functional and dynamic kinetic analysis. Nevertheless, wider use of cardiac sympathetic nervous PET imaging is still limited mainly due to the demand of costly on-site cyclotrons, which are required for the production of conventional {sup 11}C-labeled (radiological half-life, 20 min) PET tracers. Most recently, more promising {sup 18}F-labeled (half-life, 110 min) PET radiopharmaceuticals targeting sympathetic nervous system have been introduced. These tracers optimize PET imaging and, by using delivery networks, cost less to produce. In this article, the latest advances of sympathetic nervous imaging using {sup 18}F-labeled radiotracers along with their possible applications are reviewed. (orig.)

  12. Enhancing ejection fraction measurement through 4D respiratory motion compensation in cardiac PET imaging

    Science.gov (United States)

    Tang, Jing; Wang, Xinhui; Gao, Xiangzhen; Segars, W. Paul; Lodge, Martin A.; Rahmim, Arman

    2017-06-01

    ECG gated cardiac PET imaging measures functional parameters such as left ventricle (LV) ejection fraction (EF), providing diagnostic and prognostic information for management of patients with coronary artery disease (CAD). Respiratory motion degrades spatial resolution and affects the accuracy in measuring the LV volumes for EF calculation. The goal of this study is to systematically investigate the effect of respiratory motion correction on the estimation of end-diastolic volume (EDV), end-systolic volume (ESV), and EF, especially on the separation of normal and abnormal EFs. We developed a respiratory motion incorporated 4D PET image reconstruction technique which uses all gated-frame data to acquire a motion-suppressed image. Using the standard XCAT phantom and two individual-specific volunteer XCAT phantoms, we simulated dual-gated myocardial perfusion imaging data for normally and abnormally beating hearts. With and without respiratory motion correction, we measured the EDV, ESV, and EF from the cardiac-gated reconstructed images. For all the phantoms, the estimated volumes increased and the biases significantly reduced with motion correction compared with those without. Furthermore, the improvement of ESV measurement in the abnormally beating heart led to better separation of normal and abnormal EFs. The simulation study demonstrated the significant effect of respiratory motion correction on cardiac imaging data with motion amplitude as small as 0.7 cm. The larger the motion amplitude the more improvement respiratory motion correction brought about on the EF measurement. Using data-driven respiratory gating, we also demonstrated the effect of respiratory motion correction on estimating the above functional parameters from list mode patient data. Respiratory motion correction has been shown to improve the accuracy of EF measurement in clinical cardiac PET imaging.

  13. PET imaging of human cardiac opioid receptors

    Energy Technology Data Exchange (ETDEWEB)

    Villemagne, Patricia S.R.; Dannals, Robert F. [Department of Radiology, The Johns Hopkins University School of Medicine, 605 N Caroline St., Baltimore, Maryland (United States); Department of Environmental Health Sciences, The Johns Hopkins University School of Medicine, Baltimore, Maryland (United States); Ravert, Hayden T. [Department of Radiology, The Johns Hopkins University School of Medicine, 605 N Caroline St., Baltimore, Maryland (United States); Frost, James J. [Department of Radiology, The Johns Hopkins University School of Medicine, 605 N Caroline St., Baltimore, Maryland (United States); Department of Environmental Health Sciences, The Johns Hopkins University School of Medicine, Baltimore, Maryland (United States); Department of Neuroscience, The Johns Hopkins University School of Medicine, Baltimore, Maryland (United States)

    2002-10-01

    The presence of opioid peptides and receptors and their role in the regulation of cardiovascular function has been previously demonstrated in the mammalian heart. The aim of this study was to image {mu} and {delta} opioid receptors in the human heart using positron emission tomography (PET). Five subjects (three females, two males, 65{+-}8 years old) underwent PET scanning of the chest with [{sup 11}C]carfentanil ([{sup 11}C]CFN) and [{sup 11}C]-N-methyl-naltrindole ([{sup 11}C]MeNTI) and the images were analyzed for evidence of opioid receptor binding in the heart. Either [{sup 11}C]CFN or [{sup 11}C]MeNTI (20 mCi) was injected i.v. with subsequent dynamic acquisitions over 90 min. For the blocking studies, either 0.2 mg/kg or 1 mg/kg of naloxone was injected i.v. 5 min prior to the injection of [{sup 11}C]CFN and [{sup 11}C]MeNTI, respectively. Regions of interest were placed over the left ventricle, left ventricular chamber, lung and skeletal muscle. Graphical analysis demonstrated average baseline myocardial binding potentials (BP) of 4.37{+-}0.91 with [{sup 11}C]CFN and 3.86{+-}0.60 with [{sup 11}C]MeNTI. Administration of 0.2 mg/kg naloxone prior to [{sup 11}C]CFN produced a 25% reduction in BP in one subject in comparison with baseline values, and a 19% decrease in myocardial distribution volume (DV). Administration of 1 mg/kg of naloxone before [{sup 11}C]MeNTI in another subject produced a 14% decrease in BP and a 21% decrease in the myocardial DV. These results demonstrate the ability to image these receptors in vivo by PET. PET imaging of cardiac opioid receptors may help to better understand their role in cardiovascular pathophysiology and the effect of abuse of opioids and drugs on heart function. (orig.)

  14. An update on technical and methodological aspects for cardiac PET applications

    International Nuclear Information System (INIS)

    PRESOTTO, Luca; BUSNARDO, Elena; GIANOLLI, Luigi; BETTINARDI, Valentino

    2016-01-01

    Positron emission tomography (PET) is indicated for a large number of cardiac diseases: perfusion and viability studies are commonly used to evaluate coronary artery disease; PET can also be used to assess sarcoidosis and endocarditis, as well as to investigate amyloidosis. Furthermore, a hot topic for research is plaque characterization. Most of these studies are technically very challenging. High count rates and short acquisition times characterize perfusion scans while very small targets have to be imaged in inflammation/infection and plaques examinations. Furthermore, cardiac PET suffers from respiratory and cardiac motion blur. Each type of studies has specific requirements from the technical and methodological point of view, thus PET systems with overall high performances are required. Furthermore, in the era of hybrid PET/computed tomography (CT) and PET/Magnetic Resonance Imaging (MRI) systems, the combination of complementary functional and anatomical information can be used to improve diagnosis and prognosis. Moreover, PET images can be qualitatively and quantitatively improved exploiting information from the other modality, using advanced algorithms. In this review we will report the latest technological and methodological innovations for PET cardiac applications, with particular reference to the state of the art of the hybrid PET/CT and PET/MRI. We will also report the most recent advancements in software, from reconstruction algorithms to image processing and analysis programs.

  15. Is metal artefact reduction mandatory in cardiac PET/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

    Energy Technology Data Exchange (ETDEWEB)

    Ghafarian, Pardis [Shahid Beheshti University, Department of Radiation Medicine, Tehran (Iran, Islamic Republic of); Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Tehran University of Medical Sciences, Research Center for Science and Technology in Medicine, Tehran (Iran, Islamic Republic of); Aghamiri, S.M.R. [Shahid Beheshti University, Department of Radiation Medicine, Tehran (Iran, Islamic Republic of); Ay, Mohammad R. [Tehran University of Medical Sciences, Research Center for Science and Technology in Medicine, Tehran (Iran, Islamic Republic of); Tehran University of Medical Sciences, Department of Medical Physics and Biomedical Engineering, Tehran (Iran, Islamic Republic of); Tehran University of Medical Sciences, Research Institute for Nuclear Medicine, Tehran (Iran, Islamic Republic of); Rahmim, Arman [Johns Hopkins University, Department of Radiology, Baltimore, MD (United States); Schindler, Thomas H. [Geneva University, Cardiovascular Center, Nuclear Cardiology, Geneva (Switzerland); Ratib, Osman [Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Zaidi, Habib [Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Geneva University, Geneva Neuroscience Center, Geneva (Switzerland)

    2011-02-15

    Cardiac PET/CT imaging is often performed in patients with pacemakers and implantable cardioverter defibrillator (ICD) leads. However, metallic implants usually produce artefacts on CT images which might propagate to CT-based attenuation-corrected (CTAC) PET images. The impact of metal artefact reduction (MAR) for CTAC of cardiac PET/CT images in the presence of pacemaker, ICD and ECG leads was investigated using both qualitative and quantitative analysis in phantom and clinical studies. The study included 14 patients with various leads undergoing perfusion and viability examinations using dedicated cardiac PET/CT protocols. The PET data were corrected for attenuation using both artefactual CT images and CT images corrected using the MAR algorithm. The severity and magnitude of metallic artefacts arising from these leads were assessed on both linear attenuation coefficient maps ({mu}-maps) and attenuation-corrected PET images. CT and PET emission data were obtained using an anthropomorphic thorax phantom and a dedicated heart phantom made in-house incorporating pacemaker and ICD leads attached at the right ventricle of the heart. Volume of interest-based analysis and regression plots were performed for regions related to the lead locations. Bull's eye view analysis was also performed on PET images corrected for attenuation with and without the MAR algorithm. In clinical studies, the visual assessment of PET images by experienced physicians and quantitative analysis did not reveal erroneous interpretation of the tracer distribution or significant differences when PET images were corrected for attenuation with and without MAR. In phantom studies, the mean differences between tracer uptake obtained without and with MAR were 10.16{+-}2.1% and 6.86{+-}2.1% in the segments of the heart in the vicinity of metallic ICD or pacemaker leads, and were 4.43{+-}0.5% and 2.98{+-}0.5% in segments far from the leads. Although the MAR algorithm was able to effectively improve

  16. Dual respiratory and cardiac motion estimation in PET imaging: Methods design and quantitative evaluation.

    Science.gov (United States)

    Feng, Tao; Wang, Jizhe; Tsui, Benjamin M W

    2018-04-01

    The goal of this study was to develop and evaluate four post-reconstruction respiratory and cardiac (R&C) motion vector field (MVF) estimation methods for cardiac 4D PET data. In Method 1, the dual R&C motions were estimated directly from the dual R&C gated images. In Method 2, respiratory motion (RM) and cardiac motion (CM) were separately estimated from the respiratory gated only and cardiac gated only images. The effects of RM on CM estimation were modeled in Method 3 by applying an image-based RM correction on the cardiac gated images before CM estimation, the effects of CM on RM estimation were neglected. Method 4 iteratively models the mutual effects of RM and CM during dual R&C motion estimations. Realistic simulation data were generated for quantitative evaluation of four methods. Almost noise-free PET projection data were generated from the 4D XCAT phantom with realistic R&C MVF using Monte Carlo simulation. Poisson noise was added to the scaled projection data to generate additional datasets of two more different noise levels. All the projection data were reconstructed using a 4D image reconstruction method to obtain dual R&C gated images. The four dual R&C MVF estimation methods were applied to the dual R&C gated images and the accuracy of motion estimation was quantitatively evaluated using the root mean square error (RMSE) of the estimated MVFs. Results show that among the four estimation methods, Methods 2 performed the worst for noise-free case while Method 1 performed the worst for noisy cases in terms of quantitative accuracy of the estimated MVF. Methods 4 and 3 showed comparable results and achieved RMSE lower by up to 35% than that in Method 1 for noisy cases. In conclusion, we have developed and evaluated 4 different post-reconstruction R&C MVF estimation methods for use in 4D PET imaging. Comparison of the performance of four methods on simulated data indicates separate R&C estimation with modeling of RM before CM estimation (Method 3) to be

  17. Respiratory gating in cardiac PET

    DEFF Research Database (Denmark)

    Lassen, Martin Lyngby; Rasmussen, Thomas; Christensen, Thomas E

    2017-01-01

    BACKGROUND: Respiratory motion due to breathing during cardiac positron emission tomography (PET) results in spatial blurring and erroneous tracer quantification. Respiratory gating might represent a solution by dividing the PET coincidence dataset into smaller respiratory phase subsets. The aim...... of our study was to compare the resulting imaging quality by the use of a time-based respiratory gating system in two groups administered either adenosine or dipyridamole as the pharmacological stress agent. METHODS AND RESULTS: Forty-eight patients were randomized to adenosine or dipyridamole cardiac...... stress (82)RB-PET. Respiratory rates and depths were measured by a respiratory gating system in addition to registering actual respiratory rates. Patients undergoing adenosine stress showed a decrease in measured respiratory rate from initial to later scan phase measurements [12.4 (±5.7) vs 5.6 (±4...

  18. An integrated bioimpedance—ECG gating technique for respiratory and cardiac motion compensation in cardiac PET

    International Nuclear Information System (INIS)

    Koivumäki, Tuomas; Nekolla, Stephan G; Fürst, Sebastian; Loher, Simone; Schwaiger, Markus; Vauhkonen, Marko; Hakulinen, Mikko A

    2014-01-01

    Respiratory motion may degrade image quality in cardiac PET imaging. Since cardiac PET studies often involve cardiac gating by ECG, a separate respiratory monitoring system is required increasing the logistic complexity of the examination, in case respiratory gating is also needed. Thus, we investigated the simultaneous acquisition of both respiratory and cardiac gating signals using II limb lead mimicking electrode configuration during cardiac PET scans of 11 patients. In addition to conventional static and ECG-gated images, bioimpedance technique was utilized to generate respiratory- and dual-gated images. The ability of the bioimpedance technique to monitor intrathoracic respiratory motion was assessed estimating cardiac displacement between end-inspiration and -expiration. The relevance of dual gating was evaluated in left ventricular volume and myocardial wall thickness measurements. An average 7.6  ±  3.3 mm respiratory motion was observed in the study population. Dual gating showed a small but significant increase (4 ml, p = 0.042) in left ventricular myocardial volume compared to plain cardiac gating. In addition, a thinner myocardial wall was observed in dual-gated images (9.3  ±  1.3 mm) compared to cardiac-gated images (11.3  ±  1.3 mm, p = 0.003). This study shows the feasibility of bioimpedance measurements for dual gating in a clinical setting. The method enables simultaneous acquisition of respiratory and cardiac gating signals using a single device with standard ECG electrodes. (paper)

  19. Hybrid cardiac imaging using PET/MRI: a joint position statement by the European Society of Cardiovascular Radiology (ESCR) and the European Association of Nuclear Medicine (EANM).

    Science.gov (United States)

    Nensa, Felix; Bamberg, Fabian; Rischpler, Christoph; Menezes, Leon; Poeppel, Thorsten D; la Fougère, Christian; Beitzke, Dietrich; Rasul, Sazan; Loewe, Christian; Nikolaou, Konstantin; Bucerius, Jan; Kjaer, Andreas; Gutberlet, Matthias; Prakken, Niek H; Vliegenthart, Rozemarijn; Slart, Riemer H J A; Nekolla, Stephan G; Lassen, Martin L; Pichler, Bernd J; Schlosser, Thomas; Jacquier, Alexis; Quick, Harald H; Schäfers, Michael; Hacker, Marcus

    2018-05-02

    Positron emission tomography (PET) and magnetic resonance imaging (MRI) have both been used for decades in cardiovascular imaging. Since 2010, hybrid PET/MRI using sequential and integrated scanner platforms has been available, with hybrid cardiac PET/MR imaging protocols increasingly incorporated into clinical workflows. Given the range of complementary information provided by each method, the use of hybrid PET/MRI may be justified and beneficial in particular clinical settings for the evaluation of different disease entities. In the present joint position statement, we critically review the role and value of integrated PET/MRI in cardiovascular imaging, provide a technical overview of cardiac PET/MRI and practical advice related to the cardiac PET/MRI workflow, identify cardiovascular applications that can potentially benefit from hybrid PET/MRI, and describe the needs for future development and research. In order to encourage its wide dissemination, this article is freely accessible on the European Radiology and European Journal of Hybrid Imaging web sites. • Studies and case-reports indicate that PET/MRI is a feasible and robust technology. • Promising fields of application include a variety of cardiac conditions. • Larger studies are required to demonstrate its incremental and cost-effective value. • The translation of novel radiopharmaceuticals and MR-sequences will provide exciting new opportunities.

  20. An experimental phantom study of the effect of gadolinium-based MR contrast agents on PET attenuation coefficients and PET quantification in PET-MR imaging: application to cardiac studies.

    Science.gov (United States)

    O' Doherty, Jim; Schleyer, Paul

    2017-12-01

    Simultaneous cardiac perfusion studies are an increasing trend in PET-MR imaging. During dynamic PET imaging, the introduction of gadolinium-based MR contrast agents (GBCA) at high concentrations during a dual injection of GBCA and PET radiotracer may cause increased attenuation effects of the PET signal, and thus errors in quantification of PET images. We thus aimed to calculate the change in linear attenuation coefficient (LAC) of a mixture of PET radiotracer and increasing concentrations of GBCA in solution and furthermore, to investigate if this change in LAC produced a measurable effect on the image-based PET activity concentration when attenuation corrected by three different AC strategies. We performed simultaneous PET-MR imaging of a phantom in a static scenario using a fixed activity of 40 MBq [18 F]-NaF, water, and an increasing GBCA concentration from 0 to 66 mM (based on an assumed maximum possible concentration of GBCA in the left ventricle in a clinical study). This simulated a range of clinical concentrations of GBCA. We investigated two methods to calculate the LAC of the solution mixture at 511 keV: (1) a mathematical mixture rule and (2) CT imaging of each concentration step and subsequent conversion to LAC at 511 keV. This comparison showed that the ranges of LAC produced by both methods are equivalent with an increase in LAC of the mixed solution of approximately 2% over the range of 0-66 mM. We then employed three different attenuation correction methods to the PET data: (1) each PET scan at a specific millimolar concentration of GBCA corrected by its corresponding CT scan, (2) each PET scan corrected by a CT scan with no GBCA present (i.e., at 0 mM GBCA), and (3) a manually generated attenuation map, whereby all CT voxels in the phantom at 0 mM were replaced by LAC = 0.1 cm -1 . All attenuation correction methods (1-3) were accurate to the true measured activity concentration within 5%, and there were no trends in image

  1. Cardiac 82rubidium PET/CT: initial European experience

    International Nuclear Information System (INIS)

    Groves, Ashley M.; Dickson, John C.; Kayani, Irfan; Endozo, Raymondo; Blanchard, Patty; Shastry, Manu; Prvulovich, Elizabeth; Waddington, Wendy A.; Ben-Haim, Simona; Bomanji, Jamshed B.; Ell, Peter J.; Speechly-Dick, Marie-Elsya; McEwan, Jean R.

    2007-01-01

    Myocardial perfusion with PET/CT has advantages over conventional SPECT. We describe our initial European experience using 82 Rubidium-PET/CT, as part of a clinical myocardial perfusion service. We studied the first 100 patients (64 male; 36 female, mean age = 60: SD +/-12.5y, mean body mass index = 30: SD +/-6.9kg/m 2 ) who underwent 82 Rubidium cardiac PET/CT in our institution. Thirty patients had recently undergone coronary angiography. Patients underwent imaging during adenosine infusion and at rest. Images were acquired over 5 minutes using a GE-PET/CT instrument. Image quality was described as good, adequate or inadequate. Images were reported patient-by-patient by a minimum of five nuclear medicine physicians. A segment-by-segment analysis (17-segment model) was also performed. Image quality was good in 77%, adequate 23% and inadequate 0%. There was no statistical difference in image quality between obese and non-obese patients (Fisher's exact test, p = 0.2864). 59% had normal perfusion studies, 29% had inducible ischaemia, 12% had myocardial infarction (11% with super added ischaemia). There was reduced 82 Rubidium uptake in 132/1700 segments during stress. There was reduced 82 Rubidium uptake at rest in 42/1700 segments. The 82 Rubidium PET/CT findings were consistent with the angiographic findings in 28/30 cases. We show that, even from initial use of 82 Rubidium, it is possible to perform myocardial perfusion studies quickly with good image quality, even in the obese. The PET findings correlated well in the third of the cases where angiography was available. As such, 82 Rubidium cardiac PET/CT is likely to be an exciting addition to the European nuclear physician/ cardiologist's radionuclide imaging arsenal. (orig.)

  2. Comparison of volumetric and functional parameters in simultaneous cardiac PET/MR: feasibility of volumetric assessment with residual activity from prior PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Luecke, C.; Brenneis, B.; Grothoff, M.; Gutberlet, M. [University Leipzig - Heart Center, Department of Diagnostic and Interventional Radiology, Leipzig (Germany); Oppolzer, B.; Werner, P.; Jochimsen, T.; Sattler, B.; Barthel, H.; Sabri, O. [University Hospital Leipzig, Department of Nuclear Medicine, Leipzig (Germany); Foldyna, B. [University Leipzig - Heart Center, Department of Diagnostic and Interventional Radiology, Leipzig (Germany); Massachusetts General Hospital - Harvard Medical School, Cardiac MR PET CT Program, Boston, MA (United States); Lurz, P. [University Leipzig - Heart Center, Clinic for Internal Medicine/Cardiology, Leipzig (Germany); Lehmkuhl, L. [Herz- und Gefaess-Klinik GmbH, Radiologische Klinik, Bad Neustadt (Germany)

    2017-12-15

    To compare cardiac left ventricular (LV) parameters in simultaneously acquired hybrid fluorine-18-fluorodeoxyglucose ([18F] FDG) positron emission tomography/magnetic resonance imaging (PET/MRI) in patients with residual tracer activity of upstream PET/CT. Twenty-nine patients (23 men, age 58±17 years) underwent cardiac PET/MRI either directly after a non-cardiac PET/CT with homogenous cardiac [18F] FDG uptake (n=20) or for viability assessment (n=9). Gated cardiac [18F] FDG PET and cine MR sequences were acquired simultaneously and evaluated blinded to the cross-imaging results. Image quality (IQ), end-diastolic (LVEDV), end-systolic volume (LVESV), ejection fraction (LVEF) and myocardial mass (LVMM) were measured. Pearson correlation and intraclass correlation coefficient (ICC), regression and a Bland-Altman analysis were assessed. Except LVMM, volumetric and functional LV parameters demonstrated high correlations (LVESV: r=0.97, LVEDV: r=0.95, LVEF: r=0.91, LVMM: r=0.87, each p<0.05), but wide limits of agreement (LOA) for LVEDV (-25.3-82.5ml); LVESV (-33.1-72.7ml); LVEF (-18.9-14.8%) and LVMM (-78.2-43.2g). Intra- and interobserver reliability were very high (ICC≥0.95) for all parameters, except for MR-LVEF (ICC=0.87). PET-IQ (0-3) was high (mean: 2.2±0.9) with significant influence on LVMM calculations only. In simultaneously acquired cardiac PET/MRI data, LVEDV, LVESV and LVEF show good agreement. However, the agreement seems to be limited if cardiac PET/MRI follows PET/CT and only the residual activity is used. (orig.)

  3. Strategies to reduce radiation dose in cardiac PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Tung Hsin; Wu, Nien-Yun [Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei, Taiwan (China); Wang, Shyh-Jen [Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei, Taiwan (China); Department of Nuclear Medicine, Taipei Veterans General Hospital, Taipei, Taiwan (China); Wu, Jay [Institute of Radiological science, Central Taiwan University of Science and Technology, Taichung, Taiwan (China); Mok, Greta S.P. [Department of Electrical and Electronics Engineering, Faculty of Science and Technology, University of Macau, Macau (China); Yang, Ching-Ching, E-mail: g39220003@yahoo.com.tw [Department of Radiological Technology, Tzu Chi College of Technology, 880, Sec.2, Chien-kuo Rd. Hualien 970, Taiwan (China); Huang, Tzung-Chi, E-mail: tzungchi.huang@mail.cmu.edu.tw [Department of Biomedical Imaging and Radiological Science, China Medical University, No.91 Hsueh-Shih Road, Taichung 40402, Taiwan (China)

    2011-08-21

    Background: Our aim was to investigate CT dose reduction strategies on a hybrid PET/CT scanner for cardiac applications. Materials: Image quality and dose estimation of different CT scanning protocols for CT coronary angiography (CTCA), and CT-based attenuation correction for PET imaging were investigated. Fifteen patients underwent CTCA, perfusion PET imaging at rest and under stress, and FDG PET for myocardial viability. These patients were divided into three groups based on the CTCA technique performed: retrospectively gated helical (RGH), ECG tube current modulation (ETCM), and prospective gated axial (PGA) acquisitions. All emission images were corrected for photon attenuation using CT images obtained by default setting and an ultra-low dose CT (ULDCT) scan. Results: Radiation dose in RGH technique was 22.2{+-}4.0 mSv. It was reduced to 10.95{+-}0.82 and 4.13{+-}0.31 mSv using ETCM and PGA techniques, respectively. Radiation dose in CT transmission scan was reduced by 96.5% (from 4.53{+-}0.5 to 0.16{+-}0.01 mSv) when applying ULDCT as compared to the default CT. No significant difference in terms of image quality was found among various protocols. Conclusion: The proposed CT scanning strategies, i.e. ETCM or PGA for CTCA and ULDCT for PET attenuation correction, could reduce radiation dose up to 47% without degrading imaging quality in an integrated cardiac PET/CT coronary artery examination.

  4. Initial Experience With Simultaneous 18F-FDG PET/MRI in the Evaluation of Cardiac Sarcoidosis and Myocarditis.

    Science.gov (United States)

    Hanneman, Kate; Kadoch, Michael; Guo, Henry H; Jamali, Mehran; Quon, Andrew; Iagaru, Andrei; Herfkens, Robert

    2017-07-01

    The purpose of this study was to compare combined PET/MRI with PET/CT and cardiac MRI in the evaluation of cardiac sarcoidosis and myocarditis. Ten patients (4 men and 6 women; 56.1 ± 9.6 years old) were prospectively enrolled for evaluation of suspected cardiac sarcoidosis or myocarditis. Written informed consent was obtained. Following administration of 9.9 ± 0.9 mCi F-FDG, patients underwent standard cardiac PET/CT followed by combined PET/MRI using a simultaneous 3-T scanner. Cardiac MRI sequences included ECG-triggered cine SSFP, T2-weighted, and late gadolinium-enhanced imaging. Myocardial involvement was assessed with separate analysis of combined PET/MRI, PET/CT, and cardiac MRI data using dedicated postprocessing software. Estimates of radiation dose were derived from the applied doses of F-FDG and CT protocol parameters. Imaging was acquired with a delay from F-FDG injection of 90.2 ± 27.4 minutes for PET/CT and 207.7 ± 40.3 minutes for PET/MRI. Total scan time for PET/MRI was significantly longer than for PET/CT (81.4 ± 14.8 vs 12.0 minutes, P PET/MRI compared with PET/CT (6.9 ± 0.6 vs 8.2 ± 1.1 mSv, P = 0.007). There was no significant difference in the number of positive cases identified between combined PET/MRI (n = 10 [100%]), PET/CT (n = 6 [60%]), and cardiac MRI (n = 8 [80%]), P = 0.091. Simultaneous cardiac PET/MRI is feasible in the evaluation of cardiac sarcoidosis and myocarditis achieving diagnostic image quality.

  5. Ultra-low Dose CT for Attenuation Correction of 82Rb Cardiac PET

    DEFF Research Database (Denmark)

    Sørensen, Maria Balshøj; Bouchelouche, Kirsten; Tolbod, Lars Poulsen

    Aim: Myocardial perfusion imaging (MPI) using cardiac PET with tracers like 82Rb and 15O-water is substantially lower in radiation dose than classic MIBI-based SPECT. However, for cardiac PET, the dose contribution of CT for attenuation correction (CTAC) is typically 20-30% of the total dose....... To reduce the total radiation dose of cardiac PET further, we set out to examine if the use of ultra-low dose CTAC (UL-CTAC) would affect the accuracy of the quantitative parameters related to MPI. Furthermore, we examined whether the low quality of the UL-CTAC would affect the technologist’s ability...... to perform manual adjustment for misalignment between PET and CTAC. The CT reconstruction algorithm Q.AC was used to improve quality and consistency of the CTAC. Method: 23 consecutive clinical patients (BMI: 26.9 [range: 15.4-38.8]) referred for 82Rb PET rest and stress imaging were included in the study...

  6. Sources of attenuation-correction artefacts in cardiac PET/CT and SPECT/CT.

    Science.gov (United States)

    McQuaid, Sarah J; Hutton, Brian F

    2008-06-01

    Respiratory motion during myocardial perfusion imaging can cause artefacts in both positron emission tomography (PET) and single-photon emission computed tomography (SPECT) images when mismatches between emission and transmission datasets arise. In this study, artefacts from different breathing motions were quantified in both modalities to assess key factors in attenuation-correction accuracy. Activity maps were generated using the NURBS-based cardiac-torso phantom for different respiratory cycles, which were projected, attenuation-corrected and reconstructed to form PET and SPECT images. Attenuation-correction was performed with maps at mismatched respiratory phases to observe the effect on the left-ventricular myocardium. Myocardial non-uniformity was assessed in terms of the standard deviation in scores obtained from the 17-segment model and changes in uniformity were compared for each mismatch and modality. Certain types of mismatch led to artefacts and corresponding increases in the myocardial non-uniformity. For each mismatch in PET, the increases in non-uniformity relative to an artefact-free image were as follows: (a) cardiac translation mismatch, 84% +/- 11%; (b) liver mismatch, 59% +/- 10%, (c) lung mismatch from diaphragm contraction, 28% +/- 8%; and (d) lung mismatch from chest-wall motion, 6% +/- 7%. The corresponding factors for SPECT were (a) 61% +/- 8%, (b) 34% +/- 8%, (c) -2% +/- 7)% and (d) -4% +/- 6%. Attenuation-correction artefacts were seen in PET and SPECT images, with PET being more severely affected. The most severe artefacts were produced from mismatches in cardiac and liver position, whereas lung mismatches were less critical. Both cardiac and liver positions must, therefore, be correctly matched during attenuation correction.

  7. Quantitative myocardial blood flow imaging with integrated time-of-flight PET-MR.

    Science.gov (United States)

    Kero, Tanja; Nordström, Jonny; Harms, Hendrik J; Sörensen, Jens; Ahlström, Håkan; Lubberink, Mark

    2017-12-01

    The use of integrated PET-MR offers new opportunities for comprehensive assessment of cardiac morphology and function. However, little is known on the quantitative accuracy of cardiac PET imaging with integrated time-of-flight PET-MR. The aim of the present work was to validate the GE Signa PET-MR scanner for quantitative cardiac PET perfusion imaging. Eleven patients (nine male; mean age 59 years; range 46-74 years) with known or suspected coronary artery disease underwent 15 O-water PET scans at rest and during adenosine-induced hyperaemia on a GE Discovery ST PET-CT and a GE Signa PET-MR scanner. PET-MR images were reconstructed using settings recommended by the manufacturer, including time-of-flight (TOF). Data were analysed semi-automatically using Cardiac VUer software, resulting in both parametric myocardial blood flow (MBF) images and segment-based MBF values. Correlation and agreement between PET-CT-based and PET-MR-based MBF values for all three coronary artery territories were assessed using regression analysis and intra-class correlation coefficients (ICC). In addition to the cardiac PET-MR reconstruction protocol as recommended by the manufacturer, comparisons were made using a PET-CT resolution-matched reconstruction protocol both without and with TOF to assess the effect of time-of-flight and reconstruction parameters on quantitative MBF values. Stress MBF data from one patient was excluded due to movement during the PET-CT scanning. Mean MBF values at rest and stress were (0.92 ± 0.12) and (2.74 ± 1.37) mL/g/min for PET-CT and (0.90 ± 0.23) and (2.65 ± 1.15) mL/g/min for PET-MR (p = 0.33 and p = 0.74). ICC between PET-CT-based and PET-MR-based regional MBF was 0.98. Image quality was improved with PET-MR as compared to PET-CT. ICC between PET-MR-based regional MBF with and without TOF and using different filter and reconstruction settings was 1.00. PET-MR-based MBF values correlated well with PET-CT-based MBF values and

  8. Cardiac-gated parametric images from 82 Rb PET from dynamic frames and direct 4D reconstruction.

    Science.gov (United States)

    Germino, Mary; Carson, Richard E

    2018-02-01

    Cardiac perfusion PET data can be reconstructed as a dynamic sequence and kinetic modeling performed to quantify myocardial blood flow, or reconstructed as static gated images to quantify function. Parametric images from dynamic PET are conventionally not gated, to allow use of all events with lower noise. An alternative method for dynamic PET is to incorporate the kinetic model into the reconstruction algorithm itself, bypassing the generation of a time series of emission images and directly producing parametric images. So-called "direct reconstruction" can produce parametric images with lower noise than the conventional method because the noise distribution is more easily modeled in projection space than in image space. In this work, we develop direct reconstruction of cardiac-gated parametric images for 82 Rb PET with an extension of the Parametric Motion compensation OSEM List mode Algorithm for Resolution-recovery reconstruction for the one tissue model (PMOLAR-1T). PMOLAR-1T was extended to accommodate model terms to account for spillover from the left and right ventricles into the myocardium. The algorithm was evaluated on a 4D simulated 82 Rb dataset, including a perfusion defect, as well as a human 82 Rb list mode acquisition. The simulated list mode was subsampled into replicates, each with counts comparable to one gate of a gated acquisition. Parametric images were produced by the indirect (separate reconstructions and modeling) and direct methods for each of eight low-count and eight normal-count replicates of the simulated data, and each of eight cardiac gates for the human data. For the direct method, two initialization schemes were tested: uniform initialization, and initialization with the filtered iteration 1 result of the indirect method. For the human dataset, event-by-event respiratory motion compensation was included. The indirect and direct methods were compared for the simulated dataset in terms of bias and coefficient of variation as a

  9. Multimodal Registration of gated cardiac PET, CT and MR sequences

    International Nuclear Information System (INIS)

    Baty, X.

    2007-07-01

    The research described in this manuscript deals with the multimodal registration of cardiac images from Magnetic Resonance Imaging (MRI), Position Emission Tomography (PET) and Computerized Tomography (CT). All these modalities are gated to the Electrocardiogram (ECG) and provide information to evaluate cardiac function, and to diagnose and to follow-up cardiovascular pathologies. PET imaging allows the evaluation of ventricular function and MRI is a gold standard for the study of the left ventricular function. The goal of our registration process is to merge functional (from PET) and anatomical images (from CT and MRI). Our process is adapted to the modalities used and is divided in two steps: (i) a global rigid 3-dimensional model-based ICP (Iterative Closest Point) registration between CT and MR data and (ii) an iconic 2-dimensional registration based on Free Form Deformations and Mutual Information. This last step presents an original contribution by using a composite image of CT (which presents epicardic contours) and PET (where endocardic contours are partially visible) data to make mutual information more accurate in representing the similarity with the MR data. To speed up the whole process, we also present a transformation initialization scheme using displacement field obtained form MR data only. The obtained results have been evaluated by experts. (author)

  10. Automatic cardiac gating of small-animal PET from list-mode data

    Energy Technology Data Exchange (ETDEWEB)

    Herraiz, J.L.; Udias, J.M. [Universidad Complutense de Madrid Univ. (Spain). Grupo de Fisica Nuclear; Vaquero, J.J.; Desco, M. [Universidad Carlos III de Madrid (Spain). Dept. de Bioingenieria e Ingenieria Aeroespacial; Cusso, L. [Hospital General Universitario Gregorio Maranon, Madrid (Spain). Unidad de Medicina y Cirugia Experimental

    2011-07-01

    This work presents a method to obtain automatically the cardiac gating signal in a PET study of rats, by employing the variation with time of the counts in the cardiac region, that can be extracted from list-mode data. In an initial step, the cardiac region is identified in the image space by backward-projecting a small fraction of the acquired data and studying the variation with time of the counts in each voxel inside said region, with frequencies within 2 and 8 Hz. The region obtained corresponds accurately to the left-ventricle of the heart of the rat. In a second step, the lines-of-response (LORs) connected with this region are found by forward-projecting this region. The time variation of the number of counts in these LORs contains the cardiac motion information that we want to extract. This variation of counts with time is band-pass filtered to reduce noise, and the time signal so obtained is used to create the gating signal. The result was compared with a cardiac gating signal obtained from an ECG acquired simultaneously to the PET study. Reconstructed gated images obtained from both gating information are similar. The method proposed demonstrates that valid cardiac gating signals can be obtained for rats from PET list-mode data. (orig.)

  11. Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: Phantom and patient studies

    International Nuclear Information System (INIS)

    Huang, Chuan; Petibon, Yoann; Ouyang, Jinsong; El Fakhri, Georges; Reese, Timothy G.; Ahlman, Mark A.; Bluemke, David A.

    2015-01-01

    Purpose: Degradation of image quality caused by cardiac and respiratory motions hampers the diagnostic quality of cardiac PET. It has been shown that improved diagnostic accuracy of myocardial defect can be achieved by tagged MR (tMR) based PET motion correction using simultaneous PET-MR. However, one major hurdle for the adoption of tMR-based PET motion correction in the PET-MR routine is the long acquisition time needed for the collection of fully sampled tMR data. In this work, the authors propose an accelerated tMR acquisition strategy using parallel imaging and/or compressed sensing and assess the impact on the tMR-based motion corrected PET using phantom and patient data. Methods: Fully sampled tMR data were acquired simultaneously with PET list-mode data on two simultaneous PET-MR scanners for a cardiac phantom and a patient. Parallel imaging and compressed sensing were retrospectively performed by GRAPPA and kt-FOCUSS algorithms with various acceleration factors. Motion fields were estimated using nonrigid B-spline image registration from both the accelerated and fully sampled tMR images. The motion fields were incorporated into a motion corrected ordered subset expectation maximization reconstruction algorithm with motion-dependent attenuation correction. Results: Although tMR acceleration introduced image artifacts into the tMR images for both phantom and patient data, motion corrected PET images yielded similar image quality as those obtained using the fully sampled tMR images for low to moderate acceleration factors (<4). Quantitative analysis of myocardial defect contrast over ten independent noise realizations showed similar results. It was further observed that although the image quality of the motion corrected PET images deteriorates for high acceleration factors, the images were still superior to the images reconstructed without motion correction. Conclusions: Accelerated tMR images obtained with more than 4 times acceleration can still provide

  12. Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: Phantom and patient studies

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Chuan, E-mail: chuan.huang@stonybrookmedicine.edu [Center for Advanced Medical Imaging Sciences, Division of Nuclear Medicine and Molecular Imaging, Department of Imaging, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States); Department of Radiology, Harvard Medical School, Boston, Massachusetts 02115 (United States); Departments of Radiology, Psychiatry, Stony Brook Medicine, Stony Brook, New York 11794 (United States); Petibon, Yoann [Center for Advanced Medical Imaging Sciences, Division of Nuclear Medicine and Molecular Imaging, Department of Imaging, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States); Ouyang, Jinsong; El Fakhri, Georges [Center for Advanced Medical Imaging Sciences, Division of Nuclear Medicine and Molecular Imaging, Department of Imaging, Massachusetts General Hospital, Boston, Massachusetts 02114 and Department of Radiology, Harvard Medical School, Boston, Massachusetts 02115 (United States); Reese, Timothy G. [Department of Radiology, Harvard Medical School, Boston, Massachusetts 02115 and Martinos Center for Biomedical Imaging, Charlestown, Massachusetts 02129 (United States); Ahlman, Mark A.; Bluemke, David A. [Radiology and Imaging Sciences, National Institutes of Health Clinical Center, Bethesda, Maryland 20892 (United States)

    2015-02-15

    Purpose: Degradation of image quality caused by cardiac and respiratory motions hampers the diagnostic quality of cardiac PET. It has been shown that improved diagnostic accuracy of myocardial defect can be achieved by tagged MR (tMR) based PET motion correction using simultaneous PET-MR. However, one major hurdle for the adoption of tMR-based PET motion correction in the PET-MR routine is the long acquisition time needed for the collection of fully sampled tMR data. In this work, the authors propose an accelerated tMR acquisition strategy using parallel imaging and/or compressed sensing and assess the impact on the tMR-based motion corrected PET using phantom and patient data. Methods: Fully sampled tMR data were acquired simultaneously with PET list-mode data on two simultaneous PET-MR scanners for a cardiac phantom and a patient. Parallel imaging and compressed sensing were retrospectively performed by GRAPPA and kt-FOCUSS algorithms with various acceleration factors. Motion fields were estimated using nonrigid B-spline image registration from both the accelerated and fully sampled tMR images. The motion fields were incorporated into a motion corrected ordered subset expectation maximization reconstruction algorithm with motion-dependent attenuation correction. Results: Although tMR acceleration introduced image artifacts into the tMR images for both phantom and patient data, motion corrected PET images yielded similar image quality as those obtained using the fully sampled tMR images for low to moderate acceleration factors (<4). Quantitative analysis of myocardial defect contrast over ten independent noise realizations showed similar results. It was further observed that although the image quality of the motion corrected PET images deteriorates for high acceleration factors, the images were still superior to the images reconstructed without motion correction. Conclusions: Accelerated tMR images obtained with more than 4 times acceleration can still provide

  13. Dual-gated cardiac PET-clinical feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Teraes, Mika; Kokki, Tommi; Noponen, Tommi; Hoppela, Erika; Sipilae, Hannu T.; Knuuti, Juhani [Turku PET Centre, PO BOX 52, Turku (Finland); Durand-Schaefer, Nicolas [General Electric Medical Systems, Buc (France); Pietilae, Mikko [Turku University Hospital, Department of Internal Medicine, Turku (Finland); Kiss, Jan [Turku University Hospital, Department of Surgery, Turku (Finland)

    2010-03-15

    Both respiratory and cardiac motions reduce image quality in myocardial imaging. For accurate imaging of small structures such as vulnerable coronary plaques, simultaneous cardiac and respiratory gating is warranted. This study tests the feasibility of a recently developed robust method for cardiac-respiratory gating. List-mode data with triggers from respiratory and cardiac cycles are rearranged into dual-gated segments and reconstructed with standard algorithms of a commercial PET/CT scanner. Cardiac gates were defined as three fixed phases and one variable diastolic phase. Chest motion was measured with a respiratory gating device and post-processed to determine gates. Preservation of quantification in dual-gated images was tested with an IEC whole-body phantom. Minipig and human studies were performed to evaluate the feasibility of the method. In minipig studies, a coronary catheter with radioactive tip was guided in coronary artery for in vivo and ex vivo acquisitions. Dual gating in humans with suspected cardiac disorders was performed using 18-F-FDG as a tracer. The method was found feasible for in vivo imaging and the radioactive catheter tip was better resolved in gated images. In human studies, the dual gating was found feasible and easy for clinical routine. Maximal movement of myocardial surface in cranio-caudal direction was over 20 mm. The shape of myocardium was clearly different between the gates and papillary muscles become more visible in diastolic images. The first clinical experiences using robust cardiac-respiratory dual gating are encouraging. Further testing in larger clinical populations using tracers designed especially for plaque imaging is warranted. (orig.)

  14. Dual-gated cardiac PET-clinical feasibility study

    International Nuclear Information System (INIS)

    Teraes, Mika; Kokki, Tommi; Noponen, Tommi; Hoppela, Erika; Sipilae, Hannu T.; Knuuti, Juhani; Durand-Schaefer, Nicolas; Pietilae, Mikko; Kiss, Jan

    2010-01-01

    Both respiratory and cardiac motions reduce image quality in myocardial imaging. For accurate imaging of small structures such as vulnerable coronary plaques, simultaneous cardiac and respiratory gating is warranted. This study tests the feasibility of a recently developed robust method for cardiac-respiratory gating. List-mode data with triggers from respiratory and cardiac cycles are rearranged into dual-gated segments and reconstructed with standard algorithms of a commercial PET/CT scanner. Cardiac gates were defined as three fixed phases and one variable diastolic phase. Chest motion was measured with a respiratory gating device and post-processed to determine gates. Preservation of quantification in dual-gated images was tested with an IEC whole-body phantom. Minipig and human studies were performed to evaluate the feasibility of the method. In minipig studies, a coronary catheter with radioactive tip was guided in coronary artery for in vivo and ex vivo acquisitions. Dual gating in humans with suspected cardiac disorders was performed using 18-F-FDG as a tracer. The method was found feasible for in vivo imaging and the radioactive catheter tip was better resolved in gated images. In human studies, the dual gating was found feasible and easy for clinical routine. Maximal movement of myocardial surface in cranio-caudal direction was over 20 mm. The shape of myocardium was clearly different between the gates and papillary muscles become more visible in diastolic images. The first clinical experiences using robust cardiac-respiratory dual gating are encouraging. Further testing in larger clinical populations using tracers designed especially for plaque imaging is warranted. (orig.)

  15. Functional cardiac imaging: positron emission tomography

    International Nuclear Information System (INIS)

    Mullani, N.A.; Gould, K.L.

    1984-01-01

    Dynamic cardiovascular imaging plays a vital role in the diagnosis and treatment of cardiac disease by providing information about the function of the heart. During the past 30 years, cardiovascular imaging has evolved from the simple chest x-ray and fluoroscopy to such sophisticated techniques as invasive cardiac angiography and cinearteriography and, more recently, to noninvasive cardiac CT scanning, nuclear magnetic resonance, and positron emission tomography, which reflect more complex physiologic functions. As research tools, CT, NMR, and PET provide quantitative information on global as well as regional ventricular function, coronary artery stenosis, myocardial perfusion, glucose and fatty acid metabolism, or oxygen utilization, with little discomfort or risk to the patient. As imaging modalities become more sophisticated and more oriented toward clinical application, the prospect of routinely obtaining such functional information about the heart is becoming realistic. However, these advances are double-edged in that the interpretation of functional data is more complex than that of the anatomic imaging familiar to most physicians. They will require an enhanced understanding of the physiologic and biochemical processes, as well as of the instrumentation and techniques for analyzing the data. Of the new imaging modalities that provide functional information about the heart, PET is the most useful because it quantitates the regional distribution of radionuclides in vivo. Clinical applications, interpretation of data, and the impact of PET on our understanding of cardiac pathophysiology are discussed. 5 figures

  16. Simultaneous determination of dynamic cardiac metabolism and function using PET/MRI.

    Science.gov (United States)

    Barton, Gregory P; Vildberg, Lauren; Goss, Kara; Aggarwal, Niti; Eldridge, Marlowe; McMillan, Alan B

    2018-05-01

    Cardiac metabolic changes in heart disease precede overt contractile dysfunction. However, metabolism and function are not typically assessed together in clinical practice. The purpose of this study was to develop a cardiac positron emission tomography/magnetic resonance (PET/MR) stress test to assess the dynamic relationship between contractile function and metabolism in a preclinical model. Following an overnight fast, healthy pigs (45-50 kg) were anesthetized and mechanically ventilated. 18 F-fluorodeoxyglucose ( 18 F-FDG) solution was administered intravenously at a constant rate of 0.01 mL/s for 60 minutes. A cardiac PET/MR stress test was performed using normoxic gas (F I O 2  = .209) and hypoxic gas (F I O 2  = .12). Simultaneous cardiac imaging was performed on an integrated 3T PET/MR scanner. Hypoxic stress induced a significant increase in heart rate, cardiac output, left ventricular (LV) ejection fraction (EF), and peak torsion. There was a significant decline in arterial SpO 2 , LV end-diastolic and end-systolic volumes in hypoxia. Increased LV systolic function was coupled with an increase in myocardial FDG uptake (Ki) during hypoxic stress. PET/MR with continuous FDG infusion captures dynamic changes in both cardiac metabolism and contractile function. This technique warrants evaluation in human cardiac disease for assessment of subtle functional and metabolic abnormalities.

  17. Calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated 15O-water PET/CT: 5D-PET.

    Science.gov (United States)

    Nordström, Jonny; Kero, Tanja; Harms, Hendrik Johannes; Widström, Charles; Flachskampf, Frank A; Sörensen, Jens; Lubberink, Mark

    2017-11-14

    Quantitative measurement of myocardial blood flow (MBF) is of increasing interest in the clinical assessment of patients with suspected coronary artery disease (CAD). 15 O-water positron emission tomography (PET) is considered the gold standard for non-invasive MBF measurements. However, calculation of left ventricular (LV) volumes and ejection fraction (EF) is not possible from standard 15 O-water uptake images. The purpose of the present work was to investigate the possibility of calculating LV volumes and LVEF from cardiac-gated parametric blood volume (V B ) 15 O-water images and from first pass (FP) images. Sixteen patients with mitral or aortic regurgitation underwent an eight-gate dynamic cardiac-gated 15 O-water PET/CT scan and cardiac MRI. V B and FP images were generated for each gate. Calculations of end-systolic volume (ESV), end-diastolic volume (EDV), stroke volume (SV) and LVEF were performed with automatic segmentation of V B and FP images, using commercially available software. LV volumes and LVEF were calculated with surface-, count-, and volume-based methods, and the results were compared with gold standard MRI. Using V B images, high correlations between PET and MRI ESV (r = 0.89, p  0.86, p dynamic 15 O-water PET is feasible and shows good correlation with MRI. However, the analysis method is laborious, and future work is needed for more automation to make the method more easily applicable in a clinical setting.

  18. Direct reconstruction of cardiac PET kinetic parametric images using a preconditioned conjugate gradient approach.

    Science.gov (United States)

    Rakvongthai, Yothin; Ouyang, Jinsong; Guerin, Bastien; Li, Quanzheng; Alpert, Nathaniel M; El Fakhri, Georges

    2013-10-01

    Our research goal is to develop an algorithm to reconstruct cardiac positron emission tomography (PET) kinetic parametric images directly from sinograms and compare its performance with the conventional indirect approach. Time activity curves of a NCAT phantom were computed according to a one-tissue compartmental kinetic model with realistic kinetic parameters. The sinograms at each time frame were simulated using the activity distribution for the time frame. The authors reconstructed the parametric images directly from the sinograms by optimizing a cost function, which included the Poisson log-likelihood and a spatial regularization terms, using the preconditioned conjugate gradient (PCG) algorithm with the proposed preconditioner. The proposed preconditioner is a diagonal matrix whose diagonal entries are the ratio of the parameter and the sensitivity of the radioactivity associated with parameter. The authors compared the reconstructed parametric images using the direct approach with those reconstructed using the conventional indirect approach. At the same bias, the direct approach yielded significant relative reduction in standard deviation by 12%-29% and 32%-70% for 50 × 10(6) and 10 × 10(6) detected coincidences counts, respectively. Also, the PCG method effectively reached a constant value after only 10 iterations (with numerical convergence achieved after 40-50 iterations), while more than 500 iterations were needed for CG. The authors have developed a novel approach based on the PCG algorithm to directly reconstruct cardiac PET parametric images from sinograms, and yield better estimation of kinetic parameters than the conventional indirect approach, i.e., curve fitting of reconstructed images. The PCG method increases the convergence rate of reconstruction significantly as compared to the conventional CG method.

  19. Calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated 15O-water PET/CT: 5D-PET

    Directory of Open Access Journals (Sweden)

    Jonny Nordström

    2017-11-01

    Full Text Available Abstract Background Quantitative measurement of myocardial blood flow (MBF is of increasing interest in the clinical assessment of patients with suspected coronary artery disease (CAD. 15O-water positron emission tomography (PET is considered the gold standard for non-invasive MBF measurements. However, calculation of left ventricular (LV volumes and ejection fraction (EF is not possible from standard 15O-water uptake images. The purpose of the present work was to investigate the possibility of calculating LV volumes and LVEF from cardiac-gated parametric blood volume (V B 15O-water images and from first pass (FP images. Sixteen patients with mitral or aortic regurgitation underwent an eight-gate dynamic cardiac-gated 15O-water PET/CT scan and cardiac MRI. V B and FP images were generated for each gate. Calculations of end-systolic volume (ESV, end-diastolic volume (EDV, stroke volume (SV and LVEF were performed with automatic segmentation of V B and FP images, using commercially available software. LV volumes and LVEF were calculated with surface-, count-, and volume-based methods, and the results were compared with gold standard MRI. Results Using V B images, high correlations between PET and MRI ESV (r = 0.89, p  0.86, p < 0.001. Conclusion Calculation of LV volumes and LVEF from dynamic 15O-water PET is feasible and shows good correlation with MRI. However, the analysis method is laborious, and future work is needed for more automation to make the method more easily applicable in a clinical setting.

  20. Simultaneous ECG-gated PET imaging of multiple mice

    International Nuclear Information System (INIS)

    Seidel, Jurgen; Bernardo, Marcelino L.; Wong, Karen J.; Xu, Biying; Williams, Mark R.; Kuo, Frank; Jagoda, Elaine M.; Basuli, Falguni; Li, Changhui; Griffiths, Gary L.

    2014-01-01

    Introduction: We describe and illustrate a method for creating ECG-gated PET images of the heart for each of several mice imaged at the same time. The method is intended to increase “throughput” in PET research studies of cardiac dynamics or to obtain information derived from such studies, e.g. tracer concentration in end-diastolic left ventricular blood. Methods: An imaging bed with provisions for warming, anesthetic delivery, etc., was fabricated by 3D printing to allow simultaneous PET imaging of two side-by-side mice. After electrode attachment, tracer injection and placement of the animals in the scanner field of view, ECG signals from each animal were continuously analyzed and independent trigger markers generated whenever an R-wave was detected in each signal. PET image data were acquired in “list” mode and these trigger markers were inserted into this list along with the image data. Since each mouse is in a different spatial location in the FOV, sorting of these data using trigger markers first from one animal and then the other yields two independent and correctly formed ECG-gated image sequences that reflect the dynamical properties of the heart during an “average” cardiac cycle. Results: The described method yields two independent ECG-gated image sequences that exhibit the expected properties in each animal, e.g. variation of the ventricular cavity volumes from maximum to minimum and back during the cardiac cycle in the processed animal with little or no variation in these volumes during the cardiac cycle in the unprocessed animal. Conclusion: ECG-gated image sequences for each of several animals can be created from a single list mode data collection using the described method. In principle, this method can be extended to more than two mice (or other animals) and to other forms of physiological gating, e.g. respiratory gating, when several subjects are imaged at the same time

  1. Systemic and inflammatory disorders involving the heart: the role of PET imaging

    International Nuclear Information System (INIS)

    JUNEAU, Daniel; ERTHAL, Fernanda; ALZAHRANI, Atif; ALENAZY, Ali; NERY, Pablo B.; BEANLANDS, Rob S.; CHOW, Benjamin J.

    2016-01-01

    Cardiac inflammatory disorders, either primarily cardiac or secondary to a systemic process, are associated with significant morbidity and/or mortality. Their diagnosis can be challenging, especially due to significant overlap in their clinical presentation with other cardiac diseases. Recent publications have investigated the potential diagnostic role of positron emission tomography (PET) imaging in these patients. Most of the available literature is focused on Fluorine-18 fluorodeoxyglucose (FDG), a tracer which has already demonstrated its use in other inflammatory and infectious processes. PET imaging can help in the diagnosis, prognosis and follow-up in a variety of cardiac inflammatory processes, including infective endocarditis, cardiac implantable electronic device infection, pericarditis, myocarditis, sarcoidosis and amyloidosis. PET’s ability to depict metabolic changes and abnormalities, sometime even before the onset of any anatomical changes, can be a significant advantage over standard anatomical imaging. PET appears to be particularly useful in cases where standard investigation is non-diagnostic or equivocal.

  2. Dual cardiac-respiratory gated PET: implementation and results from a feasibility study

    International Nuclear Information System (INIS)

    Martinez-Moeller, Axel; Zikic, Darko; Navab, Nassir; Botnar, Rene M.; Bundschuh, Ralph A.; Ziegler, Sibylle I.; Schwaiger, Markus; Nekolla, Stephan G.; Howe, William

    2007-01-01

    Spatial resolution in myocardial imaging is impaired by both cardiac and respiratory motion owing to motional blurring. We investigated the feasibility of a dual cardiac-respiratory gated positron emission tomography (PET) acquisition using a clinical PET/computer tomography (CT) scanner. We describe its implementation and present results on the respiratory motion observed. The correlation between diaphragmatic excursion measured by real-time magnetic resonance imaging (MRI) and the expansion of the chest measured with an elastic belt was studied in six subjects. PET list mode acquisitions were then performed in 12 patients, six of them injected with 13 N-ammonia and six with 18 F-FDG. In parallel, the ECG and respiratory signals of the patients were recorded and the list mode file correspondingly sorted using a dual gated approach. Respiratory motion of the heart was quantified by measuring the displacement between the inspiratory and expiratory images in the diastolic phase by means of intensity-based non-rigid image registration. The correlation between diaphragmatic excursion and expansion of the chest was excellent (R 2 = 0.91), validating the ability of the elastic belt to provide an adequate respiratory trigger. Respiratory signals corresponding to the chest expansion showed a large inter-patient variability, requiring adapted algorithms in order to define suitable respiratory gates. Dual gated PET series were successfully acquired for both groups of patients, showing better resolved myocardial walls. The average respiratory motion of the heart measured by PET was 4.8 mm, with its largest component in the craniocaudal direction. Moreover, a deformation of the heart with respiration was observed, with the inferior wall moving significantly more than the anterior. Dual gated cardiac PET studies were performed successfully and showed better resolved myocardial walls as compared with ungated acquisitions. The respiratory motion of the heart presented a

  3. MR-based attenuation correction for cardiac FDG PET on a hybrid PET/MRI scanner: comparison with standard CT attenuation correction

    Energy Technology Data Exchange (ETDEWEB)

    Vontobel, Jan; Liga, Riccardo; Possner, Mathias; Clerc, Olivier F.; Mikulicic, Fran; Veit-Haibach, Patrick; Voert, Edwin E.G.W. ter; Fuchs, Tobias A.; Stehli, Julia; Pazhenkottil, Aju P.; Benz, Dominik C.; Graeni, Christoph; Gaemperli, Oliver; Herzog, Bernhard; Buechel, Ronny R.; Kaufmann, Philipp A. [University Hospital Zurich, Department of Nuclear Medicine, Zurich (Switzerland)

    2015-09-15

    The aim of this study was to evaluate the feasibility of attenuation correction (AC) for cardiac {sup 18}F-labelled fluorodeoxyglucose (FDG) positron emission tomography (PET) using MR-based attenuation maps. We included 23 patients with no known cardiac history undergoing whole-body FDG PET/CT imaging for oncological indications on a PET/CT scanner using time-of-flight (TOF) and subsequent whole-body PET/MR imaging on an investigational hybrid PET/MRI scanner. Data sets from PET/MRI (with and without TOF) were reconstructed using MR AC and semi-quantitative segmental (20-segment model) myocardial tracer uptake (per cent of maximum) and compared to PET/CT which was reconstructed using CT AC and served as standard of reference. Excellent correlations were found for regional uptake values between PET/CT and PET/MRI with TOF (n = 460 segments in 23 patients; r = 0.913; p < 0.0001) with narrow Bland-Altman limits of agreement (-8.5 to +12.6 %). Correlation coefficients were slightly lower between PET/CT and PET/MRI without TOF (n = 460 segments in 23 patients; r = 0.851; p < 0.0001) with broader Bland-Altman limits of agreement (-12.5 to +15.0 %). PET/MRI with and without TOF showed minimal underestimation of tracer uptake (-2.08 and -1.29 %, respectively), compared to PET/CT. Relative myocardial FDG uptake obtained from MR-based attenuation corrected FDG PET is highly comparable to standard CT-based attenuation corrected FDG PET, suggesting interchangeability of both AC techniques. (orig.)

  4. Automatic extraction of myocardial mass and volumes using parametric images from dynamic nongated PET

    DEFF Research Database (Denmark)

    Harms, Hendrik Johannes; Hansson, Nils Henrik Stubkjær; Tolbod, Lars Poulsen

    2016-01-01

    Dynamic cardiac positron emission tomography (PET) is used to quantify molecular processes in vivo. However, measurements of left-ventricular (LV) mass and volumes require electrocardiogram (ECG)-gated PET data. The aim of this study was to explore the feasibility of measuring LV geometry using non......-gated dynamic cardiac PET. METHODS: Thirty-five patients with aortic-valve stenosis and 10 healthy controls (HC) underwent a 27-min 11C-acetate PET/CT scan and cardiac magnetic resonance imaging (CMR). HC were scanned twice to assess repeatability. Parametric images of uptake rate K1 and the blood pool were......LV and WT only and an overestimation for LVEF at lower values. Intra- and inter-observer correlations were >0.95 for all PET measurements. PET repeatability accuracy in HC was comparable to CMR. CONCLUSION: LV mass and volumes are accurately and automatically generated from dynamic 11C-acetate PET without...

  5. First experience of combined cardiac PET/64-detector CT angiography with invasive angiographic validation

    International Nuclear Information System (INIS)

    Groves, Ashley M.; Kayani, Irfan; Endozo, Raymondo; Menezes, Leon J.; Prvulovich, Elizabeth; Ell, Peter J.; Speechly-Dick, Marie-Elsya; McEwan, Jean; Pugliese, Francesca; Habib, Said B.

    2009-01-01

    Despite modern CT systems and expert evaluators, the diagnostic performance of coronary CT angiography is limited by overestimation of vessel stenosis which reduces the positive predictive value (PPV) of the test. The aim of this study was to evaluate the performance of combined cardiac PET/64-detector CT angiography. Included in this retrospective study were 33 consecutive patients (5 women, 28 men; mean age 61.6 years, range 47-87 years, mean BMI 27.3±5.2 kg/m 2 ) with clinically suspected flow-limiting coronary artery disease who underwent combined cardiac PET/64-detector CT angiography and invasive angiography. Combined PET/CT images were reported by an experienced dual-accredited radiologist/nuclear physician. An experienced cardiac CT radiologist re-read the CT images without PET. Stenotic disease was defined as >50% vessel narrowing. Invasive coronary angiography was used as a reference standard. Local ethics committee approval and patient consent were obtained. CT angiography (without PET data) was concordant with invasive angiography in 31/33 patients and at a patient level, the sensitivity in detecting significant coronary artery lesions was 100%, the specificity was 82%, the PPV was 92% and the negative predictive value (NPV) was 100%. Using combined PET/CT angiography the findings were concordant with invasive angiography in 32/33 patients and at a patient level, the sensitivity was 96%, the specificity was 100%, the PPV was 100% and the NPV was 91%. The use of integrated cardiac PET/64-detector CT angiography is feasible and appears to improve some aspects of the diagnostic performance of 64-detector coronary artery angiography in detecting coronary artery disease. (orig.)

  6. Cardiac and pericardial tumors: A potential application of positron emission tomography-magnetic resonance imaging.

    Science.gov (United States)

    Fathala, Ahmed; Abouzied, Mohei; AlSugair, Abdul-Aziz

    2017-07-26

    Cardiac and pericardial masses may be neoplastic, benign and malignant, non-neoplastic such as thrombus or simple pericardial cysts, or normal variants cardiac structure can also be a diagnostic challenge. Currently, there are several imaging modalities for diagnosis of cardiac masses; each technique has its inherent advantages and disadvantages. Echocardiography, is typically the initial test utilizes in such cases, Echocardiography is considered the test of choice for evaluation and detection of cardiac mass, it is widely available, portable, with no ionizing radiation and provides comprehensive evaluation of cardiac function and valves, however, echocardiography is not very helpful in many cases such as evaluation of extracardiac extension of mass, poor tissue characterization, and it is non diagnostic in some cases. Cross sectional imaging with cardiac computed tomography provides a three dimensional data set with excellent spatial resolution but utilizes ionizing radiation, intravenous iodinated contrast and relatively limited functional evaluation of the heart. Cardiac magnetic resonance imaging (CMR) has excellent contrast resolution that allows superior soft tissue characterization. CMR offers comprehensive evaluation of morphology, function, tissue characterization. The great benefits of CMR make CMR a highly useful tool in the assessment of cardiac masses. (Fluorine 18) fluorodeoxygluocse (FDG) positron emission tomography (PET) has become a corner stone in several oncological application such as tumor staging, restaging, treatment efficiency, FDG is a very useful imaging modality in evaluation of cardiac masses. A recent advance in the imaging technology has been the development of integrated PET-MRI system that utilizes the advantages of PET and MRI in a single examination. FDG PET-MRI provides complementary information on evaluation of cardiac masses. The purpose of this review is to provide several clinical scenarios on the incremental value of PET

  7. Acquisition and automated 3-D segmentation of respiratory/cardiac-gated PET transmission images

    International Nuclear Information System (INIS)

    Reutter, B.W.; Klein, G.J.; Brennan, K.M.; Huesman, R.H.

    1996-01-01

    To evaluate the impact of respiratory motion on attenuation correction of cardiac PET data, we acquired and automatically segmented gated transmission data for a dog breathing on its own under gas anesthesia. Data were acquired for 20 min on a CTI/Siemens ECAT EXACT HR (47-slice) scanner configured for 12 gates in a static study, Two respiratory gates were obtained using data from a pneumatic bellows placed around the dog's chest, in conjunction with 6 cardiac gates from standard EKG gating. Both signals were directed to a LabVIEW-controlled Macintosh, which translated them into one of 12 gate addresses. The respiratory gating threshold was placed near end-expiration to acquire 6 cardiac-gated datasets at end-expiration and 6 cardiac-gated datasets during breaths. Breaths occurred about once every 10 sec and lasted about 1-1.5 sec. For each respiratory gate, data were summed over cardiac gates and torso and lung surfaces were segmented automatically using a differential 3-D edge detection algorithm. Three-dimensional visualizations showed that lung surfaces adjacent to the heart translated 9 mm inferiorly during breaths. Our results suggest that respiration-compensated attenuation correction is feasible with a modest amount of gated transmission data and is necessary for accurate quantitation of high-resolution gated cardiac PET data

  8. First experience of simultaneous PET/MRI for the early detection of cardiac involvement in patients with Anderson-Fabry disease

    Energy Technology Data Exchange (ETDEWEB)

    Nappi, Carmela; Altiero, Michele; Imbriaco, Massimo; Giudice, Caterina Anna; Spinelli, Letizia; Cuocolo, Alberto [University Federico II, Department of Advanced Biomedical Sciences, Naples (Italy); Nicolai, Emanuele; Aiello, Marco; Diomiaiuti, Claudio Tommaso [IRCCS SDN, Naples (Italy); Pisani, Antonio [University Federico II, Department of Public Health, Naples (Italy)

    2015-03-26

    Anderson-Fabry disease (AFD) is an X-linked lysosomal storage disorder associated with severe multiorgan dysfunction and premature death. Early diagnosis and treatment strategies play a key role in patient outcome. We investigated the potential role of hybrid PET/MR imaging in the assessment of early cardiac involvement in AFD patients. Thirteen AFD patients without cardiac symptoms and with normal left ventricular function underwent simultaneous cardiac PET/MR imaging after administration of {sup 18}F-FDG. Cardiac FDG uptake was quantified by measuring the standardized uptake value in 17 myocardial segments in each subject. The coefficient of variation (COV, i.e. the standard deviation divided by the average) of the uptake of the 17 segments was calculated as an index of heterogeneity in the heart. Six patients exhibited focal late gadolinium enhancement (LGE) indicating intramyocardial fibrosis, and four of these also had positive short inversion time inversion recovery (STIR) sequences. All patients with LGE and positive STIR MR images showed focal FDG uptake in the corresponding myocardial segments indicating inflammation. Of the seven patients with negative LGE and STIR images, five showed homogeneous FDG cardiac uptake and two showed heterogeneous FDG uptake. The COV was significantly greater in patients with focal FDG uptake (0.25 ± 0.02) than in those without (0.14 ± 0.07, p < 0.01). PET/MR imaging is clinically feasible for the early detection of cardiac involvement in patients with AFD. Further studies evaluating the role of hybrid PET/MR imaging in management of the disease in larger patient populations are warranted. (orig.)

  9. First experience of simultaneous PET/MRI for the early detection of cardiac involvement in patients with Anderson-Fabry disease

    International Nuclear Information System (INIS)

    Nappi, Carmela; Altiero, Michele; Imbriaco, Massimo; Giudice, Caterina Anna; Spinelli, Letizia; Cuocolo, Alberto; Nicolai, Emanuele; Aiello, Marco; Diomiaiuti, Claudio Tommaso; Pisani, Antonio

    2015-01-01

    Anderson-Fabry disease (AFD) is an X-linked lysosomal storage disorder associated with severe multiorgan dysfunction and premature death. Early diagnosis and treatment strategies play a key role in patient outcome. We investigated the potential role of hybrid PET/MR imaging in the assessment of early cardiac involvement in AFD patients. Thirteen AFD patients without cardiac symptoms and with normal left ventricular function underwent simultaneous cardiac PET/MR imaging after administration of 18 F-FDG. Cardiac FDG uptake was quantified by measuring the standardized uptake value in 17 myocardial segments in each subject. The coefficient of variation (COV, i.e. the standard deviation divided by the average) of the uptake of the 17 segments was calculated as an index of heterogeneity in the heart. Six patients exhibited focal late gadolinium enhancement (LGE) indicating intramyocardial fibrosis, and four of these also had positive short inversion time inversion recovery (STIR) sequences. All patients with LGE and positive STIR MR images showed focal FDG uptake in the corresponding myocardial segments indicating inflammation. Of the seven patients with negative LGE and STIR images, five showed homogeneous FDG cardiac uptake and two showed heterogeneous FDG uptake. The COV was significantly greater in patients with focal FDG uptake (0.25 ± 0.02) than in those without (0.14 ± 0.07, p < 0.01). PET/MR imaging is clinically feasible for the early detection of cardiac involvement in patients with AFD. Further studies evaluating the role of hybrid PET/MR imaging in management of the disease in larger patient populations are warranted. (orig.)

  10. Potential Applications of PET/MR Imaging in Cardiology.

    Science.gov (United States)

    Ratib, Osman; Nkoulou, René

    2014-06-01

    Recent advances in hybrid PET/MR imaging have opened new perspectives for cardiovascular applications. Although cardiac MR imaging has gained wider adoption for routine clinical applications, PET images remain the reference in many applications for which objective analysis of metabolic and physiologic parameters is needed. In particular, in cardiovascular diseases-more specifically, coronary artery disease-the use of quantitative and measurable parameters in a reproducible way is essential for the management of therapeutic decisions and patient follow-up. Functional MR images and dynamic assessment of myocardial perfusion from transit of intravascular contrast medium can provide useful criteria for identifying areas of decreased myocardial perfusion or for assessing tissue viability from late contrast enhancement of scar tissue. PET images, however, will provide more quantitative data on true tissue perfusion and metabolism. Quantitative myocardial flow can also lead to accurate assessment of coronary flow reserve. The combination of both modalities will therefore provide complementary data that can be expected to improve the accuracy and reproducibility of diagnostic procedures. But the true potential of hybrid PET/MR imaging may reside in applications beyond the domain of coronary artery disease. The combination of both modalities in assessment of other cardiac diseases such as inflammation and of other systemic diseases can also be envisioned. It is also predicted that the 2 modalities combined could help characterize atherosclerotic plaques and differentiate plaques with a high risk of rupture from stable plaques. In the future, the development of new tracers will also open new perspectives in evaluating myocardial remodeling and in assessing the kinetics of stem cell therapy in myocardial infarction. New tracers will also provide new means for evaluating alterations in cardiac innervation, angiogenesis, and even the assessment of reporter gene technologies

  11. Validation of cardiac 123I-MIBG scintigraphy in patients with Parkinson's disease who were diagnosed with dopamine PET

    International Nuclear Information System (INIS)

    Ishibashi, Kenji; Saito, Yuko; Murayama, Shigeo; Kanemaru, Kazutomi; Oda, Keiichi; Ishiwata, Kiichi; Ishii, Kenji; Mizusawa, Hidehiro

    2010-01-01

    The aim of this study was to evaluate the diagnostic potential of cardiac 123 I-labelled metaiodobenzylguanidine ( 123 I-MIBG) scintigraphy in idiopathic Parkinson's disease (PD). The diagnosis was confirmed by positron emission tomography (PET) imaging with 11 C-labelled 2β-carbomethoxy-3β-(4-fluorophenyl)-tropane ( 11 C-CFT) and 11 C-raclopride (together designated as dopamine PET). Cardiac 123 I-MIBG scintigraphy and dopamine PET were performed for 39 parkinsonian patients. To estimate the cardiac 123 I-MIBG uptake, heart to mediastinum (H/M) ratios in early and delayed images were calculated. On the basis of established clinical criteria and our dopamine PET findings, 24 patients were classified into the PD group and 15 into the non-PD (NPD) group. Both early and delayed images showed that the H/M ratios were significantly lower in the PD group than in the NPD group. When the optimal cut-off levels of the H/M ratio were set at 1.95 and 1.60 in the early and delayed images, respectively, by receiver-operating characteristic analysis, the sensitivity of cardiac 123 I-MIBG scintigraphy for the diagnosis of PD was 79.2 and 70.8% and the specificity was 93.3 and 93.3% in the early and delayed images, respectively. In the Hoehn and Yahr 1 and 2 PD patients, the sensitivity decreased by 69.2 and 53.8% in the early and delayed images, respectively. In early PD cases, cardiac 123 I-MIBG scintigraphy is of limited value in the diagnosis, because of its relatively lower sensitivity. However, because of its high specificity for the overall cases, cardiac 123 I-MIBG scintigraphy may assist in the diagnosis of PD in a complementary role with the dopaminergic neuroimaging. (orig.)

  12. Hybrid cardiac imaging: SPECT/CT and PET/CT. A joint position statement by the European Association of Nuclear Medicine (EANM), the European Society of Cardiac Radiology (ESCR) and the European Council of Nuclear Cardiology (ECNC)

    DEFF Research Database (Denmark)

    Flotats, Albert; Gutberlet, Matthias; Knuuti, Juhani

    2011-01-01

    . The European Association of Nuclear Medicine (EANM), the European Society of Cardiac Radiology (ESCR) and the European Council of Nuclear Cardiology (ECNC) in this paper want to present a position statement of the institutions on the current roles of SPECT/CT and PET/CT hybrid cardiac imaging in patients...

  13. [11C]-Acetoacetate PET imaging: a potential early marker for cardiac heart failure

    International Nuclear Information System (INIS)

    Croteau, Etienne; Tremblay, Sébastien; Gascon, Suzanne; Dumulon-Perreault, Véronique; Labbé, Sébastien M.; Rousseau, Jacques A.; Cunnane, Stephen C.; Carpentier, André C.; Bénard, François; Lecomte, Roger

    2014-01-01

    The ketone body acetoacetate could be used as an alternate nutrient for the heart, and it also has the potential to improve cardiac function in an ischemic–reperfusion model or reduce the mitochondrial production of oxidative stress involved in cardiotoxicity. In this study, [ 11 C]-acetoacetate was investigated as an early marker of intracellular damage in heart failure. Methods: A rat cardiotoxicity heart failure model was induced by doxorubicin, Dox(+). [ 14 C]-Acetoacetate, a non-positron (β −) emitting radiotracer, was used to characterize the arterial blood input function and myocardial mitochondrial uptake. Afterward, [ 11 C]-acetoacetate (β +) myocardial PET images were obtained for kinetic analysis and heart function assessment in control Dox(−) (n = 15) and treated Dox(+) (n = 6) rats. The uptake rate (K 1 ) and myocardial clearance rate (k 2 or k mono ) were extracted. Results: [ 14 C]-Acetoacetate in the blood was increased in Dox(+), from 2 min post-injection until the last withdrawal point when the heart was harvested, as well as the uptake in the heart and myocardial mitochondria (unpaired t-test, p < 0.05). PET kinetic analysis of [ 11 C]-acetoacetate showed that rate constants K 1 , k 2 and k mono were decreased in Dox(+) (p < 0.05) combined with a reduction of 24% of the left ventricular ejection fraction (p < 0.001). Conclusion: Radioactive acetoacetate ex vivo analysis [ 14 C], and in vivo kinetic [ 11 C] studies provided evidence that [ 11 C]-acetoacetate can assess heart failure Dox(+). Contrary to myocardial flow reserve (rest–stress protocol), [ 11 C]-acetoacetate can be used to assess reduced kinetic rate constants without requirement of hyperemic stress response. The proposed [ 11 C]-acetoacetate cardiac radiotracer in the investigation of heart disease is novel and paves the way to a potential role for [ 11 C]-acetoacetate in cardiac pathophysiology

  14. Dynamic low dose I-123-iodophenylpentadecanoic acid metabolic cardiac imaging

    International Nuclear Information System (INIS)

    Murray, G.L.; Magill, H.L.; Schad, N.C.

    1993-01-01

    Recognition of stunned and hibernating myocardium is essential in this era of cardiac revascularization. Positron emission tomography (PET) accurately identifies viability but is costly and unavailable to most patients. Dynamic low dose I-123-iodophenylpentadecanoic acid (IPPA) metabolic cardiac imaging is a potentially cost-effective alternative to PET. Using transmural myocardial biopsies obtained during coronary bypass surgery as the viability gold standard, resting IPPA imaging agreed with 39/43 (91%) biopsies, with a sensitivity for viability of 33/36(92%) and a specificity of 6/7 (86%) in patients with severe ischemic cardiomyopathy. Eighty percent of IPPA viable, infarcted segments improved wall motion postoperatively. Furthermore, when compared to reinjection thallium (SPECT-Tl) scans after myocardial infarction, there was IPPA-Tl concordance in 27/35 (77%)(Kappa=0.536, p=0.0003). Similar to PET, IPPA demonstrated more viability than SPECT-Tl, 26/35 (74%) vs. 18/35 (51%)(p=0.047). Finally, when compared to transvenous endomyocardial biopsy for detecting rejection following cardiac transplantation, IPPA sensitivity for ≥Grade II rejection was 100%, and IPPA screening assessment for the necessity of biopsy could result in a 31% cost-savings. Therefore, IPPA metabolic cardiac imaging is a safe, inexpensive technique with a promising future. (author)

  15. FDG PET-CT findings of extra-thoracic sarcoid are associated with cardiac sarcoid: A rationale for using FGD PET-CT for cardiac sarcoid evaluation.

    Science.gov (United States)

    Patel, Darshan C; Gunasekaran, Senthil S; Goettl, Christopher; Sweiss, Nadera J; Lu, Yang

    2017-07-05

    This retrospective study investigates the relationship between cardiac and extra-thoracic sarcoid findings on FDG PET-CT using a 72-hour pretest high-fat, high-protein, and very low-carbohydrate (HFHPVLC) diet. A total of 196 consecutive FDG PET-CT scans with 72-hour HFHPVLC diet preparation were performed between December 2014 and December 2015 in known sarcoid patients. Of these scans, 5 were excluded for non-adherence to diet preparation or underlying cancer. Cardiac and extra-thoracic sarcoid lesions were categorized and measured for radiotracer uptake. A total of 188 patients had 191 eligible FDG PET/CT scans (3 follow-up scans), of which there were 20 (10%) positive, 6 indeterminate (3%), and 165 (86%) negative for CS. Among the 20 scans positive for CS, 8 (40%) had findings of both cardiac and extra-thoracic sarcoid. Our study shows that 40% of CS patients also have FDG PET-CT findings of extra-thoracic sarcoid. This makes an intriguing case for FDG PET-CT use with pretest diet prep over cardiac MRI (CMR) for cardiac sarcoid evaluation, given that CMR is likely to overlook these extra-thoracic sites of disease.

  16. Evaluation of a low-carbohydrate diet-based preparation protocol without fasting for cardiac PET/MR imaging.

    Science.gov (United States)

    Nensa, Felix; Tezgah, E; Schweins, K; Goebel, J; Heusch, P; Nassenstein, K; Schlosser, T; Poeppel, T D

    2017-06-01

    Assessment of increased glucose uptake in inflammatory or malignant myocardial disease using PET/MRI relies on uptake suppression in normal myocardium. We evaluated the efficacy of a ≥24 hours high-fat, low-carbohydrate, and protein-permitted diet (HFLCPP) in combination with unfractionated heparin for suppression of "physiologic" myocardial glucose uptake. PET/MRI was successfully performed in 89 patients. HFLCPP was started ≥24 hours prior to PET/MRI. All patients received i.v. injection of unfractionated heparin (50 IU·kg -1 ) 15 minutes prior to FDG administration. Left ventricular FDG uptake was visually evaluated by two readers. Diffuse myocardial uptake exceeding liver uptake, isolated uptake in the lateral wall, or diffuse uptake in the entire circumference of the heart base were defined as failed suppression. Homogeneous myocardial uptake below liver uptake with/without focal uptake was defined as successful suppression. Success rate was 84%. Suppression was unsuccessful in 14 patients. No significant influence of gender (P = .40) or age (P = .21) was found. However, insufficient suppression was more common in patients younger than 45 years (20% vs 7%). PET/MR imaging completion rate was >97%. A HFLCPP diet in combination with unfractionated heparin was successfully implemented for cardiac PET/MRI and resulted in a sufficient suppression of myocardial FDG uptake in 84% of patients.

  17. Heterogeneous response of cardiac sympathetic function to cardiac resynchronization therapy in heart failure documented by 11[C]-hydroxy-ephedrine and PET/CT

    International Nuclear Information System (INIS)

    Capitanio, Selene; Nanni, Cristina; Marini, Cecilia; Bonfiglioli, Rachele; Martignani, Cristian; Dib, Bassam; Fuccio, Chiara; Boriani, Giuseppe; Picori, Lorena; Boschi, Stefano; Morbelli, Silvia

    2015-01-01

    Introduction: Cardiac resynchronization therapy (CRT) is an accepted treatment in patients with end-stage heart failure. PET permits the absolute quantification of global and regional homogeneity in cardiac sympathetic innervation. We evaluated the variation of cardiac adrenergic activity in patients with idiopathic heart failure (IHF) disease (NYHA III–IV) after CRT using 11 C-hydroxyephedrine (HED) PET/CT. Methods: Ten IHF patients (mean age = 68; range = 55–81; average left ventricular ejection fraction 26 ± 4%) implanted with a resynchronization device underwent three HED PET/CT studies: PET 1 one week after inactive device implantation; PET 2, one week after PET 1 under stimulated rhythm; PET 3, at 3 months under active CRT. A dedicated software (PMOD 3.4 version) was used to estimate global and regional cardiac uptake of HED through 17 segment polar maps. Results: At baseline, HED uptake was heterogeneously distributed throughout the left ventricle with a variation coefficient of 18 ± 5%. This variable markedly decreased after three months CRT (12 ± 5%, p < 0.01). Interestingly, subdividing the 170 myocardial segments (17 segments of each patient multiplied by the number of patients) into two groups, according to the median value of tracer uptake expressed as % of maximal myocardial uptake (76%), we observed a different behaviour depending on baseline innervation: HED uptake significantly increased only in segments with “impaired innervation” (SUV 2.61 ± 0.92 at PET1 and 3.05 ± 1.67 at three months, p < 0.01). Conclusion: As shown by HED PET/CT uptake and distribution, improvement in homogeneity of myocardial neuronal function reflected a selective improvement of tracer uptake in regions with more severe neuronal damage. Advances in Knowledge: These finding supported the presence of a myocardial regional variability in response of cardiac sympathetic system to CRT and a systemic response involving remote tissues with rich adrenergic innervation

  18. Churg-Strauss syndrome cardiac involvement evaluated by cardiac magnetic resonance imaging and positron-emission tomography: a prospective study on 20 patients

    International Nuclear Information System (INIS)

    Marmursztejn, Julien; Guillevin, Loic; Cohen, Pascal; Guilpain, Philippe; Pagnoux, Christian; Mouthon, Luc; Trebossen, Regine; Legmann, Paul; Vignaux, Olivier; Duboc, Denis

    2013-01-01

    Churg-Strauss syndrome (CSS) cardiac involvement is associated with a poor prognosis. Recently cardiac MRI (CMRI) has emerged as a promising technique to detect early CSS cardiac involvement. However, CMRI-detected myocardial delayed enhancement (MDE) could correspond to fibrosis or inflammation. Fluoro-2-deoxyglucose PET (FDG-PET) was previously used in other systemic diseases to distinguish between them. To determine whether the CMRI-MDE detected in CSS patients reflected fibrosis or myocardial inflammation, patients in CSS remission underwent FDG-PET. Twenty consecutive CSS patients in remission (BVAS = 0) were recruited. Fourteen patients [eight men, six women; mean (S.D.) age 49 (9) years; mean disease duration 3.5 (2.9) years] with CMRI-detected MDE, and six patients [four men, two women; mean (S.D.) age 44 (15) years; mean disease duration 3.5 (5.3) years] with normal CMRI underwent FDG-PET. Segments with MDE on CMRI were analysed on FDG-PET images, with myocardial FDG hypo-fixation defining fibrosis and hyper-fixation corresponding inflammation. Among the 14 patients with MDE on CMRI, FDG-PET showed 10 had hypo-fixation, 2 had hyper-fixation and 2 had normal scans. CSS duration at the time of CMRI was shorter for patients with myocardial inflammation than in those with fibrosis. The six patients with normal CMRI had normal FDG-PET images. For CSS patients in remission, CMRI detected subclinical active myocardial lesions and could be recommended to assess cardiac involvement. However, because CMRI-detected MDE can reflect fibrosis or inflammation, FDG-PET might help to distinguish between the two. (authors)

  19. Churg-Strauss syndrome cardiac involvement evaluated by cardiac magnetic resonance imaging and positron-emission tomography: a prospective study on 20 patients

    Energy Technology Data Exchange (ETDEWEB)

    Marmursztejn, Julien [Department of Cardiology, Service Frederic Joliot CEA Orsay, Hopital Cochin, AP-HP, Universite Paris Descartes, Sorbonne Paris Cite, Paris, (France); Department of Radiology, Service Frederic Joliot CEA Orsay, Hopital Cochin, AP-HP, Universite Paris Descartes, Sorbonne Paris Cite, Paris, (France); Guillevin, Loic; Cohen, Pascal; Guilpain, Philippe; Pagnoux, Christian; Mouthon, Luc [Department of Internal Medicine, Service Frederic Joliot CEA Orsay, Hopital Cochin, AP-HP, Universite Paris Descartes, Sorbonne Paris Cite, Paris, (France); Trebossen, Regine [Department of Nuclear Medicine, Service Frederic Joliot CEA Orsay, Hopital Cochin, AP-HP, Universite Paris Descartes, Sorbonne Paris Cite, Paris, (France); Legmann, Paul; Vignaux, Olivier [Department of Radiology, Service Frederic Joliot CEA Orsay, Hopital Cochin, AP-HP, Universite Paris Descartes, Sorbonne Paris Cite, Paris, (France); Duboc, Denis [Department of Cardiology, Service Frederic Joliot CEA Orsay, Hopital Cochin, AP-HP, Universite Paris Descartes, Sorbonne Paris Cite, Paris, (France)

    2013-07-01

    Churg-Strauss syndrome (CSS) cardiac involvement is associated with a poor prognosis. Recently cardiac MRI (CMRI) has emerged as a promising technique to detect early CSS cardiac involvement. However, CMRI-detected myocardial delayed enhancement (MDE) could correspond to fibrosis or inflammation. Fluoro-2-deoxyglucose PET (FDG-PET) was previously used in other systemic diseases to distinguish between them. To determine whether the CMRI-MDE detected in CSS patients reflected fibrosis or myocardial inflammation, patients in CSS remission underwent FDG-PET. Twenty consecutive CSS patients in remission (BVAS = 0) were recruited. Fourteen patients [eight men, six women; mean (S.D.) age 49 (9) years; mean disease duration 3.5 (2.9) years] with CMRI-detected MDE, and six patients [four men, two women; mean (S.D.) age 44 (15) years; mean disease duration 3.5 (5.3) years] with normal CMRI underwent FDG-PET. Segments with MDE on CMRI were analysed on FDG-PET images, with myocardial FDG hypo-fixation defining fibrosis and hyper-fixation corresponding inflammation. Among the 14 patients with MDE on CMRI, FDG-PET showed 10 had hypo-fixation, 2 had hyper-fixation and 2 had normal scans. CSS duration at the time of CMRI was shorter for patients with myocardial inflammation than in those with fibrosis. The six patients with normal CMRI had normal FDG-PET images. For CSS patients in remission, CMRI detected subclinical active myocardial lesions and could be recommended to assess cardiac involvement. However, because CMRI-detected MDE can reflect fibrosis or inflammation, FDG-PET might help to distinguish between the two. (authors)

  20. New SPECT and PET Radiopharmaceuticals for Imaging Cardiovascular Disease

    Directory of Open Access Journals (Sweden)

    Oyebola O. Sogbein

    2014-01-01

    Full Text Available Nuclear cardiology has experienced exponential growth within the past four decades with converging capacity to diagnose and influence management of a variety of cardiovascular diseases. Single photon emission computed tomography (SPECT myocardial perfusion imaging (MPI with technetium-99m radiotracers or thallium-201 has dominated the field; however new hardware and software designs that optimize image quality with reduced radiation exposure are fuelling a resurgence of interest at the preclinical and clinical levels to expand beyond MPI. Other imaging modalities including positron emission tomography (PET and magnetic resonance imaging (MRI continue to emerge as powerful players with an expanded capacity to diagnose a variety of cardiac conditions. At the forefront of this resurgence is the development of novel target vectors based on an enhanced understanding of the underlying pathophysiological process in the subcellular domain. Molecular imaging with novel radiopharmaceuticals engineered to target a specific subcellular process has the capacity to improve diagnostic accuracy and deliver enhanced prognostic information to alter management. This paper, while not comprehensive, will review the recent advancements in radiotracer development for SPECT and PET MPI, autonomic dysfunction, apoptosis, atherosclerotic plaques, metabolism, and viability. The relevant radiochemistry and preclinical and clinical development in addition to molecular imaging with emerging modalities such as cardiac MRI and PET-MR will be discussed.

  1. Validation of cardiac {sup 123}I-MIBG scintigraphy in patients with Parkinson's disease who were diagnosed with dopamine PET

    Energy Technology Data Exchange (ETDEWEB)

    Ishibashi, Kenji [Tokyo Medical and Dental University, Department of Neurology and Neurological Science, Graduate School, Tokyo (Japan); Tokyo Metropolitan Institute of Gerontology, Positron Medical Center, Tokyo (Japan); Saito, Yuko [Tokyo Metropolitan Geriatric Hospital, Department of Pathology, Tokyo (Japan); Tokyo Metropolitan Institute of Gerontology, Department of Neuropathology, Tokyo (Japan); Murayama, Shigeo [Tokyo Metropolitan Institute of Gerontology, Department of Neuropathology, Tokyo (Japan); Kanemaru, Kazutomi [Tokyo Metropolitan Geriatric Hospital, Department of Neurology, Tokyo (Japan); Oda, Keiichi; Ishiwata, Kiichi; Ishii, Kenji [Tokyo Metropolitan Institute of Gerontology, Positron Medical Center, Tokyo (Japan); Mizusawa, Hidehiro [Tokyo Medical and Dental University, Department of Neurology and Neurological Science, Graduate School, Tokyo (Japan)

    2010-01-15

    The aim of this study was to evaluate the diagnostic potential of cardiac {sup 123}I-labelled metaiodobenzylguanidine ({sup 123}I-MIBG) scintigraphy in idiopathic Parkinson's disease (PD). The diagnosis was confirmed by positron emission tomography (PET) imaging with {sup 11}C-labelled 2{beta}-carbomethoxy-3{beta}-(4-fluorophenyl)-tropane ({sup 11}C-CFT) and {sup 11}C-raclopride (together designated as dopamine PET). Cardiac {sup 123}I-MIBG scintigraphy and dopamine PET were performed for 39 parkinsonian patients. To estimate the cardiac {sup 123}I-MIBG uptake, heart to mediastinum (H/M) ratios in early and delayed images were calculated. On the basis of established clinical criteria and our dopamine PET findings, 24 patients were classified into the PD group and 15 into the non-PD (NPD) group. Both early and delayed images showed that the H/M ratios were significantly lower in the PD group than in the NPD group. When the optimal cut-off levels of the H/M ratio were set at 1.95 and 1.60 in the early and delayed images, respectively, by receiver-operating characteristic analysis, the sensitivity of cardiac {sup 123}I-MIBG scintigraphy for the diagnosis of PD was 79.2 and 70.8% and the specificity was 93.3 and 93.3% in the early and delayed images, respectively. In the Hoehn and Yahr 1 and 2 PD patients, the sensitivity decreased by 69.2 and 53.8% in the early and delayed images, respectively. In early PD cases, cardiac {sup 123}I-MIBG scintigraphy is of limited value in the diagnosis, because of its relatively lower sensitivity. However, because of its high specificity for the overall cases, cardiac {sup 123}I-MIBG scintigraphy may assist in the diagnosis of PD in a complementary role with the dopaminergic neuroimaging. (orig.)

  2. Automatic Extraction of Myocardial Mass and Volume Using Parametric Images from Dynamic Nongated PET.

    Science.gov (United States)

    Harms, Hendrik Johannes; Stubkjær Hansson, Nils Henrik; Tolbod, Lars Poulsen; Kim, Won Yong; Jakobsen, Steen; Bouchelouche, Kirsten; Wiggers, Henrik; Frøkiaer, Jørgen; Sörensen, Jens

    2016-09-01

    Dynamic cardiac PET is used to quantify molecular processes in vivo. However, measurements of left ventricular (LV) mass and volume require electrocardiogram-gated PET data. The aim of this study was to explore the feasibility of measuring LV geometry using nongated dynamic cardiac PET. Thirty-five patients with aortic-valve stenosis and 10 healthy controls underwent a 27-min (11)C-acetate PET/CT scan and cardiac MRI (CMR). The controls were scanned twice to assess repeatability. Parametric images of uptake rate K1 and the blood pool were generated from nongated dynamic data. Using software-based structure recognition, the LV wall was automatically segmented from K1 images to derive functional assessments of LV mass (mLV) and wall thickness. End-systolic and end-diastolic volumes were calculated using blood pool images and applied to obtain stroke volume and LV ejection fraction (LVEF). PET measurements were compared with CMR. High, linear correlations were found for LV mass (r = 0.95), end-systolic volume (r = 0.93), and end-diastolic volume (r = 0.90), and slightly lower correlations were found for stroke volume (r = 0.74), LVEF (r = 0.81), and thickness (r = 0.78). Bland-Altman analyses showed significant differences for mLV and thickness only and an overestimation for LVEF at lower values. Intra- and interobserver correlations were greater than 0.95 for all PET measurements. PET repeatability accuracy in the controls was comparable to CMR. LV mass and volume are accurately and automatically generated from dynamic (11)C-acetate PET without electrocardiogram gating. This method can be incorporated in a standard routine without any additional workload and can, in theory, be extended to other PET tracers. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  3. Low-dose computed tomography scans with automatic exposure control for patients of different ages undergoing cardiac PET/CT and SPECT/CT.

    Science.gov (United States)

    Yang, Ching-Ching; Yang, Bang-Hung; Tu, Chun-Yuan; Wu, Tung-Hsin; Liu, Shu-Hsin

    2017-06-01

    This study aimed to evaluate the efficacy of automatic exposure control (AEC) in order to optimize low-dose computed tomography (CT) protocols for patients of different ages undergoing cardiac PET/CT and single-photon emission computed tomography/computed tomography (SPECT/CT). One PET/CT and one SPECT/CT were used to acquire CT images for four anthropomorphic phantoms representative of 1-year-old, 5-year-old and 10-year-old children and an adult. For the hybrid systems investigated in this study, the radiation dose and image quality of cardiac CT scans performed with AEC activated depend mainly on the selection of a predefined image quality index. Multiple linear regression methods were used to analyse image data from anthropomorphic phantom studies to investigate the effects of body size and predefined image quality index on CT radiation dose in cardiac PET/CT and SPECT/CT scans. The regression relationships have a coefficient of determination larger than 0.9, indicating a good fit to the data. According to the regression models, low-dose protocols using the AEC technique were optimized for patients of different ages. In comparison with the standard protocol with AEC activated for adult cardiac examinations used in our clinical routine practice, the optimized paediatric protocols in PET/CT allow 32.2, 63.7 and 79.2% CT dose reductions for anthropomorphic phantoms simulating 10-year-old, 5-year-old and 1-year-old children, respectively. The corresponding results for cardiac SPECT/CT are 8.4, 51.5 and 72.7%. AEC is a practical way to reduce CT radiation dose in cardiac PET/CT and SPECT/CT, but the AEC settings should be determined properly for optimal effect. Our results show that AEC does not eliminate the need for paediatric protocols and CT examinations using the AEC technique should be optimized for paediatric patients to reduce the radiation dose as low as reasonably achievable.

  4. Measuring cardiac efficiency using PET/MRI

    International Nuclear Information System (INIS)

    Gullberg, Grand; Aparici, Carina Mari; Brooks, Gabriel; Liu, Jing; Guccione, Julius; Saloner, David; Seo, Adam Youngho; Ordovas, Karen Gomes

    2015-01-01

    Heart failure (HF) is a complex syndrome that is projected by the American Heart Association to cost $160 billion by 2030. In HF, significant metabolic changes and structural remodeling lead to reduced cardiac efficiency. A normal heart is approximately 20-25% efficient measured by the ratio of work to oxygen utilization (1 ml oxygen = 21 joules). The heart requires rapid production of ATP where there is complete turnover of ATP every 10 seconds with 90% of ATP produced by mitochondrial oxidative metabolism requiring substrates of approximately 30% glucose and 65% fatty acids. In our preclinical PET/MRI studies in normal rats, we showed a negative correlation between work and the influx rate constant for 18FDG, confirming that glucose is not the preferred substrate at rest. However, even though fatty acid provides 9 kcal/gram compared to 4 kcal/gram for glucose, in HF the preferred energy source is glucose. PET/MRI offers the potential to study this maladapted mechanism of metabolism by measuring work in a region of myocardial tissue simultaneously with the measure of oxygen utilization, glucose, and fatty acid metabolism and to study cardiac efficiency in the etiology of and therapies for HF. MRI is used to measure strain and a finite element mechanical model using pressure measurements is used to estimate myofiber stress. The integral of strain times stress provides a measure of work which divided by energy utilization, estimated by the production of 11CO2 from intravenous injection of 11C-acetate, provides a measure of cardiac efficiency. Our project involves translating our preclinical research to the clinical application of measuring cardiac efficiency in patients. Using PET/MRI to develop technologies for studying myocardial efficiency in patients, provides an opportunity to relate cardiac work of specific tissue regions to metabolic substrates, and measure the heterogeneity of LV efficiency.

  5. Measuring cardiac efficiency using PET/MRI

    Energy Technology Data Exchange (ETDEWEB)

    Gullberg, Grand [Lawrence Berkeley National Laboratory (United States); Aparici, Carina Mari; Brooks, Gabriel [University of California San Francisco (United States); Liu, Jing; Guccione, Julius; Saloner, David; Seo, Adam Youngho; Ordovas, Karen Gomes [Lawrence Berkeley National Laboratory (United States)

    2015-05-18

    Heart failure (HF) is a complex syndrome that is projected by the American Heart Association to cost $160 billion by 2030. In HF, significant metabolic changes and structural remodeling lead to reduced cardiac efficiency. A normal heart is approximately 20-25% efficient measured by the ratio of work to oxygen utilization (1 ml oxygen = 21 joules). The heart requires rapid production of ATP where there is complete turnover of ATP every 10 seconds with 90% of ATP produced by mitochondrial oxidative metabolism requiring substrates of approximately 30% glucose and 65% fatty acids. In our preclinical PET/MRI studies in normal rats, we showed a negative correlation between work and the influx rate constant for 18FDG, confirming that glucose is not the preferred substrate at rest. However, even though fatty acid provides 9 kcal/gram compared to 4 kcal/gram for glucose, in HF the preferred energy source is glucose. PET/MRI offers the potential to study this maladapted mechanism of metabolism by measuring work in a region of myocardial tissue simultaneously with the measure of oxygen utilization, glucose, and fatty acid metabolism and to study cardiac efficiency in the etiology of and therapies for HF. MRI is used to measure strain and a finite element mechanical model using pressure measurements is used to estimate myofiber stress. The integral of strain times stress provides a measure of work which divided by energy utilization, estimated by the production of 11CO2 from intravenous injection of 11C-acetate, provides a measure of cardiac efficiency. Our project involves translating our preclinical research to the clinical application of measuring cardiac efficiency in patients. Using PET/MRI to develop technologies for studying myocardial efficiency in patients, provides an opportunity to relate cardiac work of specific tissue regions to metabolic substrates, and measure the heterogeneity of LV efficiency.

  6. PET and MR imaging: the odd couple or a match made in heaven?

    Science.gov (United States)

    Catana, Ciprian; Guimaraes, Alexander R; Rosen, Bruce R

    2013-05-01

    PET and MR imaging are modalities routinely used for clinical and research applications. Integrated scanners capable of acquiring PET and MR imaging data in the same session, sequentially or simultaneously, have recently become available for human use. In this article, we describe some of the technical advances that allowed the development of human PET/MR scanners; briefly discuss methodologic challenges and opportunities provided by this novel technology; and present potential oncologic, cardiac, and neuropsychiatric applications. These examples range from studies that might immediately benefit from PET/MR to more advanced applications on which future development might have an even broader impact.

  7. Imaging of the myocardium using {sup 18}F-FDG-PET/MRI

    Energy Technology Data Exchange (ETDEWEB)

    Ferda, Jiří, E-mail: ferda@fnplzen.cz [Clinic of the Imaging Methods, University Hospital Plzen, Alej Svobody 80, 304 60 Plzeň (Czech Republic); Hromádka, Milan, E-mail: hromadkam@fnplzen.cz [Department of Cardiology, University Hospital Plzen, Alej Svobody 80, 304 60 Plzeň (Czech Republic); Baxa, Jan, E-mail: baxaj@fnplzen.cz [Clinic of the Imaging Methods, University Hospital Plzen, Alej Svobody 80, 304 60 Plzeň (Czech Republic)

    2016-10-15

    Highlights: • The natural combination of the metabolic and structural information is the most important strenghtof myocardial PET/MRI. • Metabolic conversion to glycolysis is needed in the assesment ov the viable myocardium. • Metabolic conversion to the fatty acid metabolism is the crucial in the assesment of the ischemic memory and myocardial inflammation. - Abstract: The introduction of the integrated hybrid PET/MRI equipment creates the possibility to perform PET and MRI simultaneously. Depending on the clinical question, the metabolic conversion to glycolytic activity or beta-oxidation is performed before the application of FDG. Since FDG aids to evaluate the energetic metabolism of the myocytes and myocardial MRI reaches the imaging capabilities of perfusion and tissue characterization in the daily routine, FDG-PET/MRI looks to be a promising method of PET/MRI exploitation in cardiac imaging. When myocardial FDG uptake should be evaluated in association with the perfusion distribution, the cross-evaluation of FDG accumulation distribution and perfusion distribution pattern is necessary. The different scenarios may be used in the assessment of myocardium, the conversion to glycolytic activity is used in the imaging of the viable myocardium, but the glycolytic activity suppression might be used in the indications of the identification of injured myocardium by ischemia or inflammation. FDG-PET/MRI might aid to answer the clinical tasks according to the structure, current function and possibilities to improve the function in ischemic heart disease or to display the extent or activity of myocardial inflammation in sarcoidosis. The tight coupling between metabolism, perfusion and contractile function offers an opportunity for the simultaneous assessment of cardiac performance using one imaging modality.

  8. EANM/ESC guidelines for radionuclide imaging of cardiac function

    DEFF Research Database (Denmark)

    Hesse, B.; Lindhardt, T.B.; Acampa, W.

    2008-01-01

    radionuclide ventriculography, gated myocardial perfusion scintigraphy, gated PET, and studies with non-imaging devices for the evaluation of cardiac function. The items covered are presented in 11 sections: clinical indications, radiopharmaceuticals and dosimetry, study acquisition, RV EF, LV EF, LV volumes...

  9. Comparison of {sup 18}F-fluorodeoxyglucose positron emission tomography (FDG PET) and cardiac magnetic resonance (CMR) in corticosteroid-naive patients with conduction system disease due to cardiac sarcoidosis

    Energy Technology Data Exchange (ETDEWEB)

    Ohira, Hiroshi; Birnie, David H.; Mc Ardle, Brian; Dick, Alexander; Klein, Ran; Renaud, Jennifer; DeKemp, Robert A.; Davies, Ross; Hessian, Renee; Liu, Peter; Nery, Pablo B. [University of Ottawa Heart Institute, Molecular Function and Imaging Program, National Cardiac PET Centre, Ottawa, ON (Canada); University of Ottawa Heart Institute, Arrhythmia Service, Division of Cardiology, Department of Medicine, Ottawa, ON (Canada); Pena, Elena; Dennie, Carole [The Ottawa Hospital, Medical Imaging Department, Ottawa, ON (Canada); University of Ottawa, Department of Radiology, Ottawa, ON (Canada); Bernick, Jordan; Wells, George A. [University of Ottawa Heart Institute, Cardiovascular Research Methods Center, Ottawa, ON (Canada); Leung, Eugene [The Ottawa Hospital, Division of Nuclear Medicine, Department of Medicine, Ottawa, Ontario (Canada); Yoshinaga, Keiichiro [Hokkaido University School of Medicine, Department of Molecular Imaging, Hokkaido (Japan); Tsujino, Ichizo; Sato, Takahiro; Nishimura, Masaharu [Hokkaido University School of Medicine, First Department of Medicine, Hokkaido (Japan); Manabe, Osamu; Tamaki, Nagara [Hokkaido University School of Medicine, Department of Nuclear Medicine, Hokkaido (Japan); Oyama-Manabe, Noriko [Hokkaido University Hospital, Diagnostic and Interventional Radiology, Hokkaido (Japan); Ruddy, Terrence D.; Beanlands, Rob S.B. [University of Ottawa Heart Institute, Molecular Function and Imaging Program, National Cardiac PET Centre, Ottawa, ON (Canada); University of Ottawa Heart Institute, Arrhythmia Service, Division of Cardiology, Department of Medicine, Ottawa, ON (Canada); The Ottawa Hospital, Medical Imaging Department, Ottawa, ON (Canada); University of Ottawa, Department of Radiology, Ottawa, ON (Canada); The Ottawa Hospital, Division of Nuclear Medicine, Department of Medicine, Ottawa, Ontario (Canada); Chow, Benjamin J.W. [University of Ottawa Heart Institute, Molecular Function and Imaging Program, National Cardiac PET Centre, Ottawa, ON (Canada); University of Ottawa Heart Institute, Arrhythmia Service, Division of Cardiology, Department of Medicine, Ottawa, ON (Canada); The Ottawa Hospital, Medical Imaging Department, Ottawa, ON (Canada); University of Ottawa, Department of Radiology, Ottawa, ON (Canada)

    2016-02-15

    Cardiac sarcoidosis (CS) is a cause of conduction system disease (CSD). {sup 18}F-Fluorodeoxyglucose-positron emission tomography (FDG PET) and cardiac magnetic resonance (CMR) are used for detection of CS. The relative diagnostic value of these has not been well studied. The aim was to compare these imaging modalities in this population. We recruited steroid-naive patients with newly diagnosed CSD due to CS. All CS patients underwent both imaging studies within 12 weeks of each other. Patients were classified into two groups: group A with chronic mild CSD (right bundle branch block and/or axis deviation), and group B with new-onset atrioventricular block (AVB, Mobitz type II or third-degree AVB). Thirty patients were included. Positive findings on both imaging studies were seen in 72 % of patients (13/18) in group A and in 58 % of patients (7/12) in group B. The remainder (28 %) of the patients in group A were positive only on CMR. Of the patients in group B, 8 % were positive only on CMR and 33 % were positive only on FDG PET. Patients in group A were more likely to be positive only on CMR, and patients in group B were more likely to be positive only on FDG PET (p = 0.02). Patients in group B positive only on FDG PET underwent CMR earlier relative to their symptomatology than patients positive only on CMR (median 7.0, IQR 1.5 - 34.3, vs. 72.0, IQR 25.0 - 79.5 days; p = 0.03). The number of positive FDG PET and CMR studies was different in patients with CSD depending on their clinical presentation. This study demonstrated that CMR can adequately detect cardiac involvement associated with chronic mild CSD. In patients presenting with new-onset AVB and a negative CMR study, FDG PET may be useful for detecting cardiac involvement due to CS. (orig.)

  10. WE-FG-202-06: The Use of Hybrid PET MRI for Identifying the Presence of Cardiac Inflammation Following External Beam Irradiation

    International Nuclear Information System (INIS)

    El-Sherif, O; Xhaferllari, I; Battista, J; Sykes, J; Butler, J; Wisenberg, G; Prato, F; Gaede, S

    2016-01-01

    Purpose: To monitor the evolution of radiation-induced cardiac inflammation in a canine model using hybrid positron emission tomography (PET/magnetic resonance imaging (MRI). Methods: Research ethics approval was obtained for a longitudinal imaging study of 5 canines after cardiac irradiation. Animals were imaged at baseline, 3 months, 6 months, and 12 months post cardiac irradiation using a hybrid PET-MRI system (Biograph mMR, Siemens Healthcare). The imaging protocol was designed to assess changes in cardiac inflammation using 18 F-fluorodeoxyglucose ( 18 F-FDG) PET tracer. In order to image cardiac inflammation, the normal myocardial uptake of glucose was suppressed prior to the injection of 18 F-FDG. The suppression of glycolysis was achieved through; fasting (16–21 hours prior to the start of imaging) and an intravenous injection of heparin immediately followed by a 20% lipid infusion 20 min prior to the injection of 18 F-FDG. The standard uptake value (SUV) obtained from 17 myocardial regions were used to compare FDG scans. All animals received a simulation CT scan (GE Medical Systems) for radiation treatment planning. Radiation treatment plans were created using the Pinncale3 treatment planning system (Philips Radiation Oncology Systems) and designed to resemble the typical cardiac exposure during left-sided breast cancer radiotherapy. Cardiac irradiations were performed in a single fraction using a TrueBeam linear accelerator (Varian Medical Systems). Results: The delivered dose (mean ± standard error) to heart, left ventricle, and left anterior descending artery were 1.7±0.1 Gy, 2.7±0.1 Gy, and 5.5±0.3 Gy respectively. At these doses, a significant increase in 18 F-FDG uptake within the entire heart relative to baseline (1.1±0.02 g/ml) uptake was observed. 18 F-FDG uptake at 3 months, 6 months, and 12 months post irradiation were 1.8±0.03 g/ml, 2.4±0.06 g/ml, and 2.6±0.11 g/ml respectively. Conclusion: Low doses of limited cardiac irradiation

  11. WE-FG-202-06: The Use of Hybrid PET MRI for Identifying the Presence of Cardiac Inflammation Following External Beam Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    El-Sherif, O; Xhaferllari, I; Battista, J [Western University, London, ON (United Kingdom); London Regional Cancer Program, London, ON (United Kingdom); Sykes, J; Butler, J [Thames Valley Veterinary Services, London, Ontario (Canada); Lawson Health Research Institute, London, Ontario (Canada); Wisenberg, G; Prato, F [Western University, London, ON (United Kingdom); Lawson Health Research Institute, London, Ontario (Canada); Gaede, S [Western University, London, ON (United Kingdom); London Regional Cancer Program, London, ON (United Kingdom); Lawson Health Research Institute, London, Ontario (Canada)

    2016-06-15

    Purpose: To monitor the evolution of radiation-induced cardiac inflammation in a canine model using hybrid positron emission tomography (PET/magnetic resonance imaging (MRI). Methods: Research ethics approval was obtained for a longitudinal imaging study of 5 canines after cardiac irradiation. Animals were imaged at baseline, 3 months, 6 months, and 12 months post cardiac irradiation using a hybrid PET-MRI system (Biograph mMR, Siemens Healthcare). The imaging protocol was designed to assess changes in cardiac inflammation using {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) PET tracer. In order to image cardiac inflammation, the normal myocardial uptake of glucose was suppressed prior to the injection of {sup 18}F-FDG. The suppression of glycolysis was achieved through; fasting (16–21 hours prior to the start of imaging) and an intravenous injection of heparin immediately followed by a 20% lipid infusion 20 min prior to the injection of {sup 18}F-FDG. The standard uptake value (SUV) obtained from 17 myocardial regions were used to compare FDG scans. All animals received a simulation CT scan (GE Medical Systems) for radiation treatment planning. Radiation treatment plans were created using the Pinncale3 treatment planning system (Philips Radiation Oncology Systems) and designed to resemble the typical cardiac exposure during left-sided breast cancer radiotherapy. Cardiac irradiations were performed in a single fraction using a TrueBeam linear accelerator (Varian Medical Systems). Results: The delivered dose (mean ± standard error) to heart, left ventricle, and left anterior descending artery were 1.7±0.1 Gy, 2.7±0.1 Gy, and 5.5±0.3 Gy respectively. At these doses, a significant increase in {sup 18}F-FDG uptake within the entire heart relative to baseline (1.1±0.02 g/ml) uptake was observed. {sup 18}F-FDG uptake at 3 months, 6 months, and 12 months post irradiation were 1.8±0.03 g/ml, 2.4±0.06 g/ml, and 2.6±0.11 g/ml respectively. Conclusion: Low doses of

  12. Oncology PET imaging

    International Nuclear Information System (INIS)

    Inubushi, Masayuki

    2014-01-01

    At the beginning of this article, likening medical images to 'Where is Waldo?' I indicate the concept of diagnostic process of PET/CT imaging, so that medical physics specialists could understand the role of each imaging modality and infer our distress for image diagnosis. Then, I state the present situation of PET imaging and the basics (e.g. health insurance coverage, clinical significance, principle, protocol, and pitfall) of oncology FDG-PET imaging which accounts for more than 99% of all clinical PET examinations in Japan. Finally, I would like to give a wishful prospect of oncology PET that will expand to be more cancer-specific in order to assess therapeutic effects of emerging molecular targeted drugs targeting the 'hallmarks of cancer'. (author)

  13. Assessment of biodistribution of 131-IPPA in cardiac and non-cardiac tissues in laboratory animals by imaging

    International Nuclear Information System (INIS)

    Moradkani, S.; Sadadi, F.; Matloubi, M.; Jalilian, A. R.; Shafaie, K.; Karimian, A. R.; Daneshvari, S.

    2007-01-01

    The main substrate of myocardial metabolism is fatty acids which constitutes the principal agent for myocardial consumption and provides almost 60-80% of the energy utilized by the heart in the resting state. Evaluation of cardiac metabolism is important for the assessment of some of cardiac disorders such as Ischemic Heart disease (IHD), cardiomyopathy (functional disorders) and Hypertensive cardiac disorders. Today, almost in all of the developed countries, PET is the first step for diagnosis and assessment of cardiac metabolic disorders. It is, however, too expensive to be used in all centers and are not available in all countries. In this regards, 123-IPPA was introduced as a substitute of PET system for evaluation of cardiac function (metabolism) and it is a complementary method for other Para-clinical methods. We decided to have a preliminary study on IPPA and due to the lack of 123-I, we had to use 131-I. The labeling of IPPA by 131-I, purification and sterilization of 131-1PPA done by the Chemistry Group of Cyclotron Ward and the bio-kinetic and imaging of rat, mice (Laboratory Animals) were performed in the Nuclear Medicine Group. After injection of a proper dose of this radiotracer, the imaging was performed in an appropriate time. In our first images, there were intensive accumulation of tracer in animals' thyroid glands, though after the intake of Lugol solution, the thyroid did not appear and we had a number of excellent images of animal heart that was the target organ

  14. Imaging and PET - PET/CT imaging

    International Nuclear Information System (INIS)

    Von Schulthess, G.K.; Hany, Th.F.

    2008-01-01

    PET/CT has grown because the lack of anatomic landmarks in PET makes 'hardware-fusion' to anatomic cross-sectional data extremely useful. Addition of CT to PET improves specificity, but also sensitivity, and adding PET to CT adds sensitivity and specificity in tumor imaging. The synergistic advantage of adding CT is that the attenuation correction needed for PET data can also be derived from the CT data. This makes PET-CT 25-30% faster than PET alone, leading to higher patient throughput and a more comfortable examination for patients typically lasting 20 minutes or less. FDG-PET-CT appears to provide relevant information in the staging and therapy monitoring of many tumors, such as lung carcinoma, colorectal cancer, lymphoma, gynaecological cancers, melanoma and many others, with the notable exception of prostatic cancer. for this cancer, choline derivatives may possibly become useful radiopharmaceuticals. The published literature on the applications of FDG-PET-CT in oncology is still limited but several designed studies have demonstrated the benefits of PET-CT. (authors)

  15. PET-CMR in heart failure - synergistic or redundant imaging?

    Science.gov (United States)

    Quail, Michael A; Sinusas, Albert J

    2017-07-01

    Imaging in heart failure (HF) provides data for diagnosis, prognosis and disease monitoring. Both MRI and nuclear imaging techniques have been successfully used for this purpose in HF. Positron Emission Tomography-Cardiac Magnetic Resonance (PET-CMR) is an example of a new multimodality diagnostic imaging technique with potential applications in HF. The threshold for adopting a new diagnostic tool to clinical practice must necessarily be high, lest they exacerbate costs without improving care. New modalities must demonstrate clinical superiority, or at least equivalence, combined with another important advantage, such as lower cost or improved patient safety. The purpose of this review is to outline the current status of multimodality PET-CMR with regard to HF applications, and determine whether the clinical utility of this new technology justifies the cost.

  16. Is it time for cardiac innervation imaging?

    Energy Technology Data Exchange (ETDEWEB)

    Knuuti, J. [Turku Univ., Turku (Finland) Turku PET Center; Sipola, P. [Kuopio Univ., Kuopio (Finland)

    2005-03-01

    The autonomic nervous system plays an important role in the regulation of cardiac function and the regional distribution of cardiac nerve terminals can be visualized using scintigraphic techniques. The most commonly used tracer is iodine-123-metaiodobenzylguanidine (MIBG) but C-11-hydroxyephedrine has also been used with PET. When imaging with MIBG, the ratio of heart-to-mediastinal counts is used as an index of tracer uptake, and regional distribution is also assessed from tomographic images. The rate of clearance of the tracer can also be measured and indicates the function of the adrenergic system. Innervation imaging has been applied in patients with susceptibility to arrythmias, coronary artery disease, hypertrophic and dilated cardiomyopathy and anthracycline induced cardiotoxicity. Abnormal adrenergic innervation or function appear to exist in many pathophysiological conditions indicating that sympathetic neurons are very susceptible to damage. Abnormal findings in innervation imaging also appear to have significant prognostic value especially in patients with cardiomyopathy. Recently, it has also been shown that innervation imaging can monitor drug-induced changes in cardiac adrenergic activity. Although innervation imaging holds great promise for clinical use, the method has not received wider clinical acceptance. Larger randomized studies are required to confirm the value of innervation imaging in various specific indications.

  17. A Case of Low-Grade Primary Cardiac Lymphoma with Pericardial Effusion Diagnosed by Combined 18F-Fluorodeoxyglucose Positron Emission Tomography and Computed Tomography (FDG-PET/CT) Imaging and Effusion Cytology.

    Science.gov (United States)

    Fukunaga, Hisanori; Tatewaki, Yasuko; Mutoh, Tatsushi; Shimomura, Hideo; Yamamoto, Shuzo; Terao, Chiaki; Totsune, Tomoko; Nakagawa, Manabu; Taki, Yasuyuki

    2018-03-14

    BACKGROUND Primary cardiac lymphoma is rare and can be an aggressive disease, depending on the grade. A case is reported of low-grade primary cardiac lymphoma associated with a pericardial effusion. 18F-fluorodeoxyglucose positron emission tomography and computed tomography (FDG-PET/CT) imaging was useful in the diagnosis and in evaluating the disease activity in this case. CASE REPORT A 72-year-old Japanese woman visited a general practitioner, complaining of dyspnea associated with cardiac tamponade. Pericardiocentesis was performed, and Group V malignant cells were identified by cytology, suspicious for malignant lymphoma. Whole-body FDG-PET/CT scans showed no pleural effusion or lymph node metastasis supporting the diagnosis of primary cardiac lymphoma diagnosed on pericardial effusion. The laboratory investigations showed that levels of serum soluble interleukin-2 (IL-2) receptor (sIL-2R), a diagnostic and prognostic marker for malignant lymphoma, were not elevated (258 U/ml). A six-month follow-up FDG-PET/CT scan showed an increased volume of the pericardial effusion and mild but abnormal uptake diffusely in the pericardial space, and the sIL-2R was slightly elevated (860 U/ml). No abnormal FDG accumulation outside the retained pericardial effusion was noted, which was compatible with a clinical picture of low-grade primary cardiac lymphoma, and in a period of watchful waiting during the first two years later, the sIL-2R had reduced to 195 U/ml. CONCLUSIONS This is a rare case of low-grade primary cardiac lymphoma detected in a pericardial effusion, and highlights the utility of the FDG-PET/CT scan as a valuable diagnostic and follow-up modality.

  18. A knowledge-based method for reducing attenuation artefacts caused by cardiac appliances in myocardial PET/CT

    International Nuclear Information System (INIS)

    Hamill, James J; Brunken, Richard C; Bybel, Bohdan; DiFilippo, Frank P; Faul, David D

    2006-01-01

    Attenuation artefacts due to implanted cardiac defibrillator leads have previously been shown to adversely impact cardiac PET/CT imaging. In this study, the severity of the problem is characterized, and an image-based method is described which reduces the resulting artefact in PET. Automatic implantable cardioverter defibrillator (AICD) leads cause a moving-metal artefact in the CT sections from which the PET attenuation correction factors (ACFs) are derived. Fluoroscopic cine images were measured to demonstrate that the defibrillator's highly attenuating distal shocking coil moves rhythmically across distances on the order of 1 cm. Rhythmic motion of this magnitude was created in a phantom with a moving defibrillator lead. A CT study of the phantom showed that the artefact contained regions of incorrect, very high CT values and adjacent regions of incorrect, very low CT values. The study also showed that motion made the artefact more severe. A knowledge-based metal artefact reduction method (MAR) is described that reduces the magnitude of the error in the CT images, without use of the corrupted sinograms. The method modifies the corrupted image through a sequence of artefact detection procedures, morphological operations, adjustments of CT values and three-dimensional filtering. The method treats bone the same as metal. The artefact reduction method is shown to run in a few seconds, and is validated by applying it to a series of phantom studies in which reconstructed PET tracer distribution values are wrong by as much as 60% in regions near the CT artefact when MAR is not applied, but the errors are reduced to about 10% of expected values when MAR is applied. MAR changes PET image values by a few per cent in regions not close to the artefact. The changes can be larger in the vicinity of bone. In patient studies, the PET reconstruction without MAR sometimes results in anomalously high values in the infero-septal wall. Clinical performance of MAR is assessed by two

  19. High-precision γ -ray spectroscopy of the cardiac PET imaging isotope 82Rb and its impact on dosimetry

    Science.gov (United States)

    Nino, M. N.; McCutchan, E. A.; Smith, S. V.; Lister, C. J.; Greene, J. P.; Carpenter, M. P.; Muench, L.; Sonzogni, A. A.; Zhu, S.

    2016-02-01

    82Rb is a positron-emitting isotope used in cardiac positron emission tomography (PET) imaging which has been reported to deliver a significantly lower effective radiation dose than analogous imaging isotopes like 201Tl and 99 mTc sestamibi. High-quality β -decay data are essential to accurately appraise the total dose received by the patients. A source of 82Sr was produced at the Brookhaven Linac Isotope Producer (BLIP), transported to Argonne National Laboratory, and studied with the Gammasphere facility. Significant revisions have been made to the level scheme of 82Kr including 12 new levels, 50 new γ -ray transitions, and the determination of many new spin assignments through angular correlations. These new high-quality data allow a precise reappraisal of the β -decay strength function and thus the consequent dose received by patients.

  20. Trends in PET imaging

    International Nuclear Information System (INIS)

    Moses, William W.

    2000-01-01

    Positron Emission Tomography (PET) imaging is a well established method for obtaining information on the status of certain organs within the human body or in animals. This paper presents an overview of recent trends PET instrumentation. Significant effort is being expended to develop new PET detector modules, especially those capable of measuring depth of interaction. This is aided by recent advances in scintillator and pixellated photodetector technology. The other significant area of effort is development of special purpose PET cameras (such as for imaging breast cancer or small animals) or cameras that have the ability to image in more than one modality (such as PET / SPECT or PET / X-Ray CT)

  1. Impact of motion compensation and partial volume correction for 18F-NaF PET/CT imaging of coronary plaque

    Science.gov (United States)

    Cal-González, J.; Tsoumpas, C.; Lassen, M. L.; Rasul, S.; Koller, L.; Hacker, M.; Schäfers, K.; Beyer, T.

    2018-01-01

    Recent studies have suggested that 18F-NaF-PET enables visualization and quantification of plaque micro-calcification in the coronary tree. However, PET imaging of plaque calcification in the coronary arteries is challenging because of the respiratory and cardiac motion as well as partial volume effects. The objective of this work is to implement an image reconstruction framework, which incorporates compensation for respiratory as well as cardiac motion (MoCo) and partial volume correction (PVC), for cardiac 18F-NaF PET imaging in PET/CT. We evaluated the effect of MoCo and PVC on the quantification of vulnerable plaques in the coronary arteries. Realistic simulations (Biograph TPTV, Biograph mCT) and phantom acquisitions (Biograph mCT) were used for these evaluations. Different uptake values in the calcified plaques were evaluated in the simulations, while three ‘plaque-type’ lesions of 36, 31 and 18 mm3 were included in the phantom experiments. After validation, the MoCo and PVC methods were applied in four pilot NaF-PET patient studies. In all cases, the MoCo-based image reconstruction was performed using the STIR software. The PVC was obtained from a local projection (LP) method, previously evaluated in preclinical and clinical PET. The results obtained show a significant increase of the measured lesion-to-background ratios (LBR) in the MoCo  +  PVC images. These ratios were further enhanced when using directly the tissue-activities from the LP method, making this approach more suitable for the quantitative evaluation of coronary plaques. When using the LP method on the MoCo images, LBR increased between 200% and 1119% in the simulated data, between 212% and 614% in the phantom experiments and between 46% and 373% in the plaques with positive uptake observed in the pilot patients. In conclusion, we have built and validated a STIR framework incorporating MoCo and PVC for 18F-NaF PET imaging of coronary plaques. First results indicate an improved

  2. Economic and biological costs of cardiac imaging

    Directory of Open Access Journals (Sweden)

    Picano Eugenio

    2005-05-01

    Full Text Available Abstract Medical imaging market consists of several billion tests per year worldwide. Out of these, at least one third are cardiovascular procedures. Keeping in mind that each test represents a cost, often a risk, and a diagnostic hypothesis, we can agree that every unnecessary and unjustifiable test is one test too many. Small individual costs, risks, and wastes multiplied by billions of examinations per year represent an important population, society and environmental burden. Unfortunately, the appropriateness of cardiac imaging is extra-ordinarily low and there is little awareness in patients and physicians of differential costs, radiological doses, and long term risks of different imaging modalities. For a resting cardiac imaging test, being the average cost (not charges of an echocardiogram equal to 1 (as a cost comparator, the cost of a CT is 3.1x, of a SPECT 3.27x, of a Cardiovascular Magnetic Resonance imaging 5.51x, of a PET 14.03x, and of a right and left heart catheterization 19.96x. For stress cardiac imaging, compared with the treadmill exercise test equal to 1 (as a cost comparator, the cost of stress echocardiography is 2.1x and of a stress SPECT scintigraphy is 5.7x. Biohazards and downstream long-term costs linked to radiation-induced oncogenesis should also be considered. The radiation exposure is absent in echo and magnetic resonance, and corresponds to 500 chest x rays for a sestamibi cardiac stress scan and to 1150 chest x rays for a thallium scan. The corresponding extra-risk in a lifetime of fatal cancer is 1 in 2000 exposed patients for a sestamibi stress and 1 in 1000 for a thallium scan. Increased awareness of economic, biologic, and environmental costs of cardiac imaging will hopefully lead to greater appropriateness, wisdom and prudence from both the prescriber and the practitioner. In this way, the sustainability of cardiac imaging will eventually improve.

  3. PET/MR Imaging in Gynecologic Oncology.

    Science.gov (United States)

    Ohliger, Michael A; Hope, Thomas A; Chapman, Jocelyn S; Chen, Lee-May; Behr, Spencer C; Poder, Liina

    2017-08-01

    MR imaging and PET using 2-Deoxy-2-[ 18 F]fluoroglucose (FDG) are both useful in the evaluation of gynecologic malignancies. MR imaging is superior for local staging of disease whereas fludeoxyglucose FDG PET is superior for detecting distant metastases. Integrated PET/MR imaging scanners have great promise for gynecologic malignancies by combining the advantages of each modality into a single scan. This article reviews the technology behind PET/MR imaging acquisitions and technical challenges relevant to imaging the pelvis. A dedicated PET/MR imaging protocol; the roles of PET and MR imaging in cervical, endometrial, and ovarian cancers; and future directions for PET/MR imaging are discussed. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Cardiac retention of PET neuronal imaging agent LMI1195 in different species: Impact of norepinephrine uptake-1 and -2 transporters

    International Nuclear Information System (INIS)

    Yu, Ming; Bozek, Jody; Kagan, Mikhail; Guaraldi, Mary; Silva, Paula; Azure, Michael; Onthank, David; Robinson, Simon P.

    2013-01-01

    Introduction: Released sympathetic neurotransmitter norepinephrine (NE) in the heart is cleared by neuronal uptake-1 and extraneuronal uptake-2 transporters. Cardiac uptake-1 and -2 expression varies among species, but the uptake-1 is the primary transporter in humans. LMI1195 is an NE analog labeled with 18 F for PET evaluation of cardiac neuronal function. This study investigated the impact of cardiac neuronal uptake-1 associated with different species on LMI1195 heart uptake. Methods: Cardiac uptake-1 was blocked by desipramine, a selective uptake-1 inhibitor, and sympathetic neuronal denervation was induced by 6-hydroxydopamine, a neurotoxin, in rats, rabbits and nonhuman primates (NHP). Tissue biodistribution and cardiac imaging of LMI1195 and 123 I-metaiodobenzylguanidine (MIBG) were performed. Results: In rats, uptake-1 blockade did not alter LMI1195 heart uptake compared to the control at 60-min post injection [1.41 ± 0.07 vs. 1.47 ± 0.23 % injected dose per gram tissue (%ID/g)]. In contrast, LMI1195 heart uptake was reduced by 80% in uptake-1 blocked rabbits. In sympathetically denervated rats, LMI1195 heart uptake was similar to the control (2.18 ± 0.40 vs. 2.58 ± 0.76 %ID/g). However, the uptake decreased by 79% in denervated rabbits. Similar results were found in MIBG heart uptake in rats and rabbits with uptake-1 blockade. Consistently, LMI1195 cardiac imaging showed comparable myocardial activity in uptake-1 blocked or sympathetically denervated rats to the control, but marked activity reduction in uptake-1 blocked or denervated rabbits and NHPs. Conclusions: LMI1195 is retained in the heart of rabbits and NHPs primarily via the neuronal uptake-1 with high selectivity and can be used for evaluation of cardiac sympathetic denervation. Similar to the human, the neuronal uptake-1 is the dominant transporter for cardiac retention of NE analogs in rabbits and NHPs, but not in rats

  5. Enhancement of dynamic myocardial perfusion PET images based on low-rank plus sparse decomposition.

    Science.gov (United States)

    Lu, Lijun; Ma, Xiaomian; Mohy-Ud-Din, Hassan; Ma, Jianhua; Feng, Qianjin; Rahmim, Arman; Chen, Wufan

    2018-02-01

    The absolute quantification of dynamic myocardial perfusion (MP) PET imaging is challenged by the limited spatial resolution of individual frame images due to division of the data into shorter frames. This study aims to develop a method for restoration and enhancement of dynamic PET images. We propose that the image restoration model should be based on multiple constraints rather than a single constraint, given the fact that the image characteristic is hardly described by a single constraint alone. At the same time, it may be possible, but not optimal, to regularize the image with multiple constraints simultaneously. Fortunately, MP PET images can be decomposed into a superposition of background vs. dynamic components via low-rank plus sparse (L + S) decomposition. Thus, we propose an L + S decomposition based MP PET image restoration model and express it as a convex optimization problem. An iterative soft thresholding algorithm was developed to solve the problem. Using realistic dynamic 82 Rb MP PET scan data, we optimized and compared its performance with other restoration methods. The proposed method resulted in substantial visual as well as quantitative accuracy improvements in terms of noise versus bias performance, as demonstrated in extensive 82 Rb MP PET simulations. In particular, the myocardium defect in the MP PET images had improved visual as well as contrast versus noise tradeoff. The proposed algorithm was also applied on an 8-min clinical cardiac 82 Rb MP PET study performed on the GE Discovery PET/CT, and demonstrated improved quantitative accuracy (CNR and SNR) compared to other algorithms. The proposed method is effective for restoration and enhancement of dynamic PET images. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. A knowledge-based method for reducing attenuation artefacts caused by cardiac appliances in myocardial PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Hamill, James J [Siemens Medical Solutions, Molecular Imaging, 810 Innovation Dr., Knoxville, TN (United States); Brunken, Richard C [Department of Molecular and Functional Imaging, Cleveland Clinic Foundation, 9500 Euclid Ave., Cleveland, OH (United States); Bybel, Bohdan [Department of Molecular and Functional Imaging, Cleveland Clinic Foundation, 9500 Euclid Ave., Cleveland, OH (United States); DiFilippo, Frank P [Department of Molecular and Functional Imaging, Cleveland Clinic Foundation, 9500 Euclid Ave., Cleveland, OH (United States); Faul, David D [Siemens Medical Solutions, Molecular Imaging, 810 Innovation Dr., Knoxville, TN (United States)

    2006-06-07

    Attenuation artefacts due to implanted cardiac defibrillator leads have previously been shown to adversely impact cardiac PET/CT imaging. In this study, the severity of the problem is characterized, and an image-based method is described which reduces the resulting artefact in PET. Automatic implantable cardioverter defibrillator (AICD) leads cause a moving-metal artefact in the CT sections from which the PET attenuation correction factors (ACFs) are derived. Fluoroscopic cine images were measured to demonstrate that the defibrillator's highly attenuating distal shocking coil moves rhythmically across distances on the order of 1 cm. Rhythmic motion of this magnitude was created in a phantom with a moving defibrillator lead. A CT study of the phantom showed that the artefact contained regions of incorrect, very high CT values and adjacent regions of incorrect, very low CT values. The study also showed that motion made the artefact more severe. A knowledge-based metal artefact reduction method (MAR) is described that reduces the magnitude of the error in the CT images, without use of the corrupted sinograms. The method modifies the corrupted image through a sequence of artefact detection procedures, morphological operations, adjustments of CT values and three-dimensional filtering. The method treats bone the same as metal. The artefact reduction method is shown to run in a few seconds, and is validated by applying it to a series of phantom studies in which reconstructed PET tracer distribution values are wrong by as much as 60% in regions near the CT artefact when MAR is not applied, but the errors are reduced to about 10% of expected values when MAR is applied. MAR changes PET image values by a few per cent in regions not close to the artefact. The changes can be larger in the vicinity of bone. In patient studies, the PET reconstruction without MAR sometimes results in anomalously high values in the infero-septal wall. Clinical performance of MAR is assessed by

  7. Imaging with PET system

    International Nuclear Information System (INIS)

    Das, B.K.; Noreen Norfaraheen Lee Abdullah

    2012-01-01

    PET deals with biochemistry and metabolic changes that occur at molecular level. Hence, PET differs fundamentally from other imaging modalities. CT imaging is based on tissue density, whereas MRI conveys anatomic information based on proton density and proton relaxation dynamics. CT and MRI are useful in clinical diagnosis only when disease process has caused significant anatomic alterations. However, in most disease conditions chemical changes precede anatomic changes, that can be detected by PET technology. Thus, PET can provide earliest and unique information about ongoing disease process long before anatomic or structural changes take place. There is no other modality available at present that can replace PET technology. Although PET produces cross-sectional images like that obtained in MRI or CT, they represent circulation, function and metabolism, and not anatomic structure. PET is extremely sensitive measuring quantitatively concentration of tracers in nano to pico-molar range. Thus, PET enables merger of biochemistry and biology in medicine giving birth to molecular medicine that focuses on identifying the molecular errors of disease leading to developing molecular corrections including gene therapy. Molecular imaging with PET has been playing a role in examining the biological nature of a disease condition and its characterization to guide selection and evaluation of treatment. (author)

  8. Quantitative PET imaging with the 3T MR-BrainPET

    International Nuclear Information System (INIS)

    Weirich, C.; Scheins, J.; Lohmann, P.; Tellmann, L.; Byars, L.; Michel, C.; Rota Kops, E.; Brenner, D.; Herzog, H.; Shah, N.J.

    2013-01-01

    The new hybrid imaging technology of MR-PET allows for simultaneous acquisition of versatile MRI contrasts and the quantitative metabolic imaging with PET. In order to achieve the quantification of PET images with minimal residual error the application of several corrections is crucial. In this work we present our results on quantification with the 3T MR BrainPET scanner

  9. Simultaneous cardiac output and regional myocardial perfusion determination with PET and nitrogen 13 ammonia

    DEFF Research Database (Denmark)

    Hove, Jens D; Kofoed, Klaus F; Wu, Hsiao M

    2003-01-01

    The purpose of this study was to evaluate the possibility of measuring cardiac output during positron emission tomography (PET) examination of myocardial perfusion with nitrogen 13 ammonia.......The purpose of this study was to evaluate the possibility of measuring cardiac output during positron emission tomography (PET) examination of myocardial perfusion with nitrogen 13 ammonia....

  10. Respiratory gating of cardiac PET data in list-mode acquisition

    International Nuclear Information System (INIS)

    Livieratos, Lefteris; Rajappan, Kim; Camici, Paolo G.; Stegger, Lars; Schafers, Klaus; Bailey, Dale L.

    2006-01-01

    Respiratory motion has been identified as a source of artefacts in most medical imaging modalities. This paper reports on respiratory gating as a means to eliminate motion-related inaccuracies in PET imaging. Respiratory gating was implemented in list mode with physiological signal recorded every millisecond together with the PET data. Respiration was monitored with an inductive respiration monitor using an elasticised belt around the patient's chest. Simultaneous ECG gating can be maintained independently by encoding ECG trigger signal into the list-mode data. Respiratory gating is performed in an off-line workstation with gating parameters defined retrospectively. The technique was applied on a preliminary set of patient data with C 15 O. Motion was visually observed in the cine displays of the sagittal and coronal views of the reconstructed respiratory gated images. Significant changes in the cranial-caudal position of the heart could be observed. The centroid of the cardiac blood pool showed an excursion of 4.5-16.5 mm (mean 8.5±4.8 mm) in the cranial-caudal direction, with more limited excursion of 1.1-7.0 mm (mean 2.5±2.2 mm) in the horizontal direction and 1.3-3.7 mm (mean 2.4±0.9 mm) in the vertical direction. These preliminary data show that the extent of motion involved in respiration is comparable to myocardial wall thickness, and respiratory gating may be considered in order to reduce this effect in the reconstructed images. (orig.)

  11. Respiratory gating of cardiac PET data in list-mode acquisition.

    Science.gov (United States)

    Livieratos, Lefteris; Rajappan, Kim; Stegger, Lars; Schafers, Klaus; Bailey, Dale L; Camici, Paolo G

    2006-05-01

    Respiratory motion has been identified as a source of artefacts in most medical imaging modalities. This paper reports on respiratory gating as a means to eliminate motion-related inaccuracies in PET imaging. Respiratory gating was implemented in list mode with physiological signal recorded every millisecond together with the PET data. Respiration was monitored with an inductive respiration monitor using an elasticised belt around the patient's chest. Simultaneous ECG gating can be maintained independently by encoding ECG trigger signal into the list-mode data. Respiratory gating is performed in an off-line workstation with gating parameters defined retrospectively. The technique was applied on a preliminary set of patient data with C(15)O. Motion was visually observed in the cine displays of the sagittal and coronal views of the reconstructed respiratory gated images. Significant changes in the cranial-caudal position of the heart could be observed. The centroid of the cardiac blood pool showed an excursion of 4.5-16.5 mm (mean 8.5+/-4.8 mm) in the cranial-caudal direction, with more limited excursion of 1.1-7.0 mm (mean 2.5+/-2.2 mm) in the horizontal direction and 1.3-3.7 mm (mean 2.4+/-0.9 mm) in the vertical direction. These preliminary data show that the extent of motion involved in respiration is comparable to myocardial wall thickness, and respiratory gating may be considered in order to reduce this effect in the reconstructed images.

  12. Quantitation of cardiac sympathetic innervation in rabbits using 11C-hydroxyephedrine PET: relation to 123I-MIBG uptake

    International Nuclear Information System (INIS)

    Nomura, Yusuke; Kajinami, Kouji; Matsunari, Ichiro; Takamatsu, Hiroyuki; Murakami, Yoshihiro; Matsuya, Takahiro; Chen, Wei-Ping; Taki, Junichi; Nakajima, Kenichi; Nekolla, Stephan G.

    2006-01-01

    Although 11 C-hydroxyephedrine ( 11 C-HED) PET is used to map cardiac sympathetic innervation, no studies have shown the feasibility of quantitation of 11 C-HED PET in small- to medium-sized animals. Furthermore, its relation to 123 I-MIBG uptake, the most widely used sympathetic nervous tracer, is unknown. The aims of this study were to establish in vivo sympathetic nerve imaging in rabbits using 11 C-HED PET, and to compare the retention of 11 C-HED with that of 123 I-MIBG. Twelve rabbits were assigned to three groups; control (n=4), chemical denervation by 6-hydroxydopamine (6-OHDA) (n=4) and reserpine treated to inhibit vesicular uptake (n=4). After simultaneous injection of 11 C-HED and 123 I-MIBG, all animals underwent dynamic 11 C-HED PET for 40 min with arterial blood sampling. The 11 C-HED retention fraction and normalised 11 C-HED activity measured by tissue sampling were compared with those measured by PET. Both the 11 C-HED retention fraction and the normalised 11 C-HED activity measured by PET correlated closely with those measured by tissue sampling (R=0.96027, p 11 C-HED and 123 I-MIBG. Reserpine pretreatment reduced 11 C-HED retention by 50%, but did not reduce 123 I-MIBG retention at 40 min after injection. Non-invasive quantitation of cardiac sympathetic innervation using 11 C-HED PET is feasible and gives reliable estimates of cardiac sympathetic innervation in rabbits. Additionally, although both 11 C-HED and 123 I-MIBG are specific for sympathetic neurons, 11 C-HED may be more specific for intravesicular uptake than 123 I-MIBG in some situations, such as that seen in reserpine pretreatment. (orig.)

  13. Magnetic Resonance-based Motion Correction for Quantitative PET in Simultaneous PET-MR Imaging.

    Science.gov (United States)

    Rakvongthai, Yothin; El Fakhri, Georges

    2017-07-01

    Motion degrades image quality and quantitation of PET images, and is an obstacle to quantitative PET imaging. Simultaneous PET-MR offers a tool that can be used for correcting the motion in PET images by using anatomic information from MR imaging acquired concurrently. Motion correction can be performed by transforming a set of reconstructed PET images into the same frame or by incorporating the transformation into the system model and reconstructing the motion-corrected image. Several phantom and patient studies have validated that MR-based motion correction strategies have great promise for quantitative PET imaging in simultaneous PET-MR. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Head and neck imaging with PET and PET/CT: artefacts from dental metallic implants

    International Nuclear Information System (INIS)

    Goerres, Gerhard W.; Hany, Thomas F.; Kamel, Ehab; Schulthess von, Gustav K.; Buck, Alfred

    2002-01-01

    Germanium-68 based attenuation correction (PET Ge68 ) is performed in positron emission tomography (PET) imaging for quantitative measurements. With the recent introduction of combined in-line PET/CT scanners, CT data can be used for attenuation correction. Since dental implants can cause artefacts in CT images, CT-based attenuation correction (PET CT ) may induce artefacts in PET images. The purpose of this study was to evaluate the influence of dental metallic artwork on the quality of PET images by comparing non-corrected images and images attenuation corrected by PET Ge68 and PET CT . Imaging was performed on a novel in-line PET/CT system using a 40-mAs scan for PET CT in 41 consecutive patients with high suspicion of malignant or inflammatory disease. In 17 patients, additional PET Ge68 images were acquired in the same imaging session. Visual analysis of fluorine-18 fluorodeoxyglucose (FDG) distribution in several regions of the head and neck was scored on a 4-point scale in comparison with normal grey matter of the brain in the corresponding PET images. In addition, artefacts adjacent to dental metallic artwork were evaluated. A significant difference in image quality scoring was found only for the lips and the tip of the nose, which appeared darker on non-corrected than on corrected PET images. In 33 patients, artefacts were seen on CT, and in 28 of these patients, artefacts were also seen on PET imaging. In eight patients without implants, artefacts were seen neither on CT nor on PET images. Direct comparison of PET Ge68 and PET CT images showed a different appearance of artefacts in 3 of 17 patients. Malignant lesions were equally well visible using both transmission correction methods. Dental implants, non-removable bridgework etc. can cause artefacts in attenuation-corrected images using either a conventional 68 Ge transmission source or the CT scan obtained with a combined PET/CT camera. We recommend that the non-attenuation-corrected PET images also be

  15. A Score-Based Approach to 18F-FDG PET Images as a Tool to Describe Metabolic Predictors of Myocardial Doxorubicin Susceptibility

    Directory of Open Access Journals (Sweden)

    Matteo Bauckneht

    2017-10-01

    Full Text Available Purpose: To verify the capability of 18F-fluorodeoxy-glucose positron emission tomography/computed tomography (FDG-PET/CT to identify patients at higher risk of developing doxorubicin (DXR-induced cardiotoxicity, using a score-based image approach. Methods: 36 patients underwent FDG-PET/CT. These patients had shown full remission after DXR-based chemotherapy for Hodgkin’s disease (DXR dose: 40–50 mg/m2 per cycle, and were retrospectively enrolled. Inclusion criteria implied the presence of both pre- and post-chemotherapy clinical evaluation encompassing electrocardiogram (ECG and echocardiography. Myocardial metabolism at pre-therapy PET was evaluated according to both standardized uptake value (SUV- and score-based approaches. The capability of the score-based image assessment to predict the occurrence of cardiac toxicity with respect to SUV measurement was then evaluated. Results: In contrast to the SUV-based approach, the five-point scale method does not linearly stratify the risk of the subsequent development of cardiotoxicity. However, converting the five-points scale to a dichotomic evaluation (low vs. high myocardial metabolism, FDG-PET/CT showed high diagnostic accuracy in the prediction of cardiac toxicity (specificity = 100% and sensitivity = 83.3%. In patients showing high myocardial uptake at baseline, in which the score-based method is not able to definitively exclude the occurrence of cardiac toxicity, myocardial SUV mean quantification is able to further stratify the risk between low and intermediate risk classes. Conclusions: the score-based approach to FDG-PET/CT images is a feasible method for predicting DXR-induced cardiotoxicity. This method might improve the inter-reader and inter-scanner variability, thus allowing the evaluation of FDG-PET/CT images in a multicentral setting.

  16. Predicting standard-dose PET image from low-dose PET and multimodal MR images using mapping-based sparse representation

    International Nuclear Information System (INIS)

    Wang, Yan; Zhou, Jiliu; Zhang, Pei; An, Le; Ma, Guangkai; Kang, Jiayin; Shi, Feng; Shen, Dinggang; Wu, Xi; Lalush, David S; Lin, Weili

    2016-01-01

    Positron emission tomography (PET) has been widely used in clinical diagnosis for diseases and disorders. To obtain high-quality PET images requires a standard-dose radionuclide (tracer) injection into the human body, which inevitably increases risk of radiation exposure. One possible solution to this problem is to predict the standard-dose PET image from its low-dose counterpart and its corresponding multimodal magnetic resonance (MR) images. Inspired by the success of patch-based sparse representation (SR) in super-resolution image reconstruction, we propose a mapping-based SR (m-SR) framework for standard-dose PET image prediction. Compared with the conventional patch-based SR, our method uses a mapping strategy to ensure that the sparse coefficients, estimated from the multimodal MR images and low-dose PET image, can be applied directly to the prediction of standard-dose PET image. As the mapping between multimodal MR images (or low-dose PET image) and standard-dose PET images can be particularly complex, one step of mapping is often insufficient. To this end, an incremental refinement framework is therefore proposed. Specifically, the predicted standard-dose PET image is further mapped to the target standard-dose PET image, and then the SR is performed again to predict a new standard-dose PET image. This procedure can be repeated for prediction refinement of the iterations. Also, a patch selection based dictionary construction method is further used to speed up the prediction process. The proposed method is validated on a human brain dataset. The experimental results show that our method can outperform benchmark methods in both qualitative and quantitative measures. (paper)

  17. Usefulness of abdominal belt for restricting respiratory cardiac motion and improving image quality in myocardial perfusion PET.

    Science.gov (United States)

    Ichikawa, Yasutaka; Tomita, Yoya; Ishida, Masaki; Kobayashi, Shigeki; Takeda, Kan; Sakuma, Hajime

    2018-04-01

    The current study evaluated the usefulness of a belt technique for restricting respiratory motion of the heart and for improving image quality of 13 N-ammonia myocardial PET/CT, and it assessed the tolerability of the belt technique in the clinical setting. Myocardial 13 N-ammonia PET/CT scanning was performed in 8 volunteers on Discovery PET/CT 690 with an optical respiratory motion tracking system. Emission scans were performed with and without an abdominal belt. The amplitude of left ventricular (LV) respiratory motion was measured on respiratory-gated PET images. The degree of erroneous decreases in regional myocardial uptake was visually assessed on ungated PET images using a 5-point scale (0 = normal, 1/2/3 = mild/moderate/severe decrease, 4 = defect). The tolerability of the belt technique was evaluated in 53 patients. All subjects tolerated the belt procedure. The amplitude of the LV respiratory motion decreased significantly with the belt (8.1 ± 7.1 vs 12.1 ± 6.1 mm, P = .0078). The belt significantly improved the image quality scores in the anterior (0.29 ± 0.81 vs 0.71 ± 1.04, P = .015) and inferior (0.33 ± 0.92 vs 1.04 ± 1.04, P PET/CT, and it is well tolerated by patients.

  18. Prediction of standard-dose brain PET image by using MRI and low-dose brain [{sup 18}F]FDG PET images

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Jiayin [School of Electronics Engineering, Huaihai Institute of Technology, Lianyungang, Jiangsu 222005, China and IDEA Laboratory, Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 (United States); Gao, Yaozong [IDEA Laboratory, Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 and Department of Computer Science, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 (United States); Shi, Feng [IDEA Laboratory, Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 (United States); Lalush, David S. [Joint UNC-NCSU Department of Biomedical Engineering, North Carolina State University, Raleigh, North Carolina 27695 (United States); Lin, Weili [MRI Laboratory, Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 (United States); Shen, Dinggang, E-mail: dgshen@med.unc.edu [IDEA Laboratory, Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 and Department of Brain and Cognitive Engineering, Korea University, Seoul 136-713 (Korea, Republic of)

    2015-09-15

    Purpose: Positron emission tomography (PET) is a nuclear medical imaging technology that produces 3D images reflecting tissue metabolic activity in human body. PET has been widely used in various clinical applications, such as in diagnosis of brain disorders. High-quality PET images play an essential role in diagnosing brain diseases/disorders. In practice, in order to obtain high-quality PET images, a standard-dose radionuclide (tracer) needs to be used and injected into a living body. As a result, it will inevitably increase the patient’s exposure to radiation. One solution to solve this problem is predicting standard-dose PET images using low-dose PET images. As yet, no previous studies with this approach have been reported. Accordingly, in this paper, the authors propose a regression forest based framework for predicting a standard-dose brain [{sup 18}F]FDG PET image by using a low-dose brain [{sup 18}F]FDG PET image and its corresponding magnetic resonance imaging (MRI) image. Methods: The authors employ a regression forest for predicting the standard-dose brain [{sup 18}F]FDG PET image by low-dose brain [{sup 18}F]FDG PET and MRI images. Specifically, the proposed method consists of two main steps. First, based on the segmented brain tissues (i.e., cerebrospinal fluid, gray matter, and white matter) in the MRI image, the authors extract features for each patch in the brain image from both low-dose PET and MRI images to build tissue-specific models that can be used to initially predict standard-dose brain [{sup 18}F]FDG PET images. Second, an iterative refinement strategy, via estimating the predicted image difference, is used to further improve the prediction accuracy. Results: The authors evaluated their algorithm on a brain dataset, consisting of 11 subjects with MRI, low-dose PET, and standard-dose PET images, using leave-one-out cross-validations. The proposed algorithm gives promising results with well-estimated standard-dose brain [{sup 18}F]FDG PET

  19. Prediction of standard-dose brain PET image by using MRI and low-dose brain ["1"8F]FDG PET images

    International Nuclear Information System (INIS)

    Kang, Jiayin; Gao, Yaozong; Shi, Feng; Lalush, David S.; Lin, Weili; Shen, Dinggang

    2015-01-01

    Purpose: Positron emission tomography (PET) is a nuclear medical imaging technology that produces 3D images reflecting tissue metabolic activity in human body. PET has been widely used in various clinical applications, such as in diagnosis of brain disorders. High-quality PET images play an essential role in diagnosing brain diseases/disorders. In practice, in order to obtain high-quality PET images, a standard-dose radionuclide (tracer) needs to be used and injected into a living body. As a result, it will inevitably increase the patient’s exposure to radiation. One solution to solve this problem is predicting standard-dose PET images using low-dose PET images. As yet, no previous studies with this approach have been reported. Accordingly, in this paper, the authors propose a regression forest based framework for predicting a standard-dose brain ["1"8F]FDG PET image by using a low-dose brain ["1"8F]FDG PET image and its corresponding magnetic resonance imaging (MRI) image. Methods: The authors employ a regression forest for predicting the standard-dose brain ["1"8F]FDG PET image by low-dose brain ["1"8F]FDG PET and MRI images. Specifically, the proposed method consists of two main steps. First, based on the segmented brain tissues (i.e., cerebrospinal fluid, gray matter, and white matter) in the MRI image, the authors extract features for each patch in the brain image from both low-dose PET and MRI images to build tissue-specific models that can be used to initially predict standard-dose brain ["1"8F]FDG PET images. Second, an iterative refinement strategy, via estimating the predicted image difference, is used to further improve the prediction accuracy. Results: The authors evaluated their algorithm on a brain dataset, consisting of 11 subjects with MRI, low-dose PET, and standard-dose PET images, using leave-one-out cross-validations. The proposed algorithm gives promising results with well-estimated standard-dose brain ["1"8F]FDG PET image and substantially

  20. Demons versus level-set motion registration for coronary 18F-sodium fluoride PET

    Science.gov (United States)

    Rubeaux, Mathieu; Joshi, Nikhil; Dweck, Marc R.; Fletcher, Alison; Motwani, Manish; Thomson, Louise E.; Germano, Guido; Dey, Damini; Berman, Daniel S.; Newby, David E.; Slomka, Piotr J.

    2016-03-01

    Ruptured coronary atherosclerotic plaques commonly cause acute myocardial infarction. It has been recently shown that active microcalcification in the coronary arteries, one of the features that characterizes vulnerable plaques at risk of rupture, can be imaged using cardiac gated 18F-sodium fluoride (18F-NaF) PET. We have shown in previous work that a motion correction technique applied to cardiac-gated 18F-NaF PET images can enhance image quality and improve uptake estimates. In this study, we further investigated the applicability of different algorithms for registration of the coronary artery PET images. In particular, we aimed to compare demons vs. level-set nonlinear registration techniques applied for the correction of cardiac motion in coronary 18F-NaF PET. To this end, fifteen patients underwent 18F-NaF PET and prospective coronary CT angiography (CCTA). PET data were reconstructed in 10 ECG gated bins; subsequently these gated bins were registered using demons and level-set methods guided by the extracted coronary arteries from CCTA, to eliminate the effect of cardiac motion on PET images. Noise levels, target-to-background ratios (TBR) and global motion were compared to assess image quality. Compared to the reference standard of using only diastolic PET image (25% of the counts from PET acquisition), cardiac motion registration using either level-set or demons techniques almost halved image noise due to the use of counts from the full PET acquisition and increased TBR difference between 18F-NaF positive and negative lesions. The demons method produces smoother deformation fields, exhibiting no singularities (which reflects how physically plausible the registration deformation is), as compared to the level-set method, which presents between 4 and 8% of singularities, depending on the coronary artery considered. In conclusion, the demons method produces smoother motion fields as compared to the level-set method, with a motion that is physiologically

  1. PET measurements of myocardial blood flow post myocardial infarction: Relationship to invasive and cardiac magnetic resonance studies and potential clinical applications.

    Science.gov (United States)

    Gewirtz, Henry

    2017-12-01

    This review focuses on clinical studies concerning assessment of coronary microvascular and conduit vessel function primarily in the context of acute and sub acute myocardial infarction (MI). The ability of quantitative PET measurements of myocardial blood flow (MBF) to delineate underlying pathophysiology and assist in clinical decision making in this setting is discussed. Likewise, considered are physiological metrics fractional flow reserve, coronary flow reserve, index of microvascular resistance (FFR, CFR, IMR) obtained from invasive studies performed in the cardiac catheterization laboratory, typically at the time of PCI for MI. The role both of invasive studies and cardiac magnetic resonance (CMR) imaging in assessing microvascular function, a key determinant of prognosis, is reviewed. The interface between quantitative PET MBF measurements and underlying pathophysiology, as demonstrated both by invasive and CMR methodology, is discussed in the context of optimal interpretation of the quantitative PET MBF exam and its potential clinical applications.

  2. PET and SPET tracers for mapping the cardiac nervous system

    International Nuclear Information System (INIS)

    Langer, Oliver; Halldin, Christer

    2002-01-01

    The human cardiac nervous system consists of a sympathetic and a parasympathetic branch with (-)-norepinephrine and acetylcholine as the respective endogenous neurotransmitters. Dysfunction of the cardiac nervous system is implicated in various types of cardiac disease, such as heart failure, myocardial infarction and diabetic autonomic neuropathy. In vivo assessment of the distribution and function of cardiac sympathetic and parasympathetic neurones with positron emission tomography (PET) and single-photon emission tomography (SPET) can be achieved by means of a number of carbon-11-, fluorine-18-, bromine-76- and iodine-123-labelled tracer molecules. Available tracers for mapping sympathetic neurones can be divided into radiolabelled catecholamines, such as 6-[ 18 F]fluorodopamine, (-)-6-[ 18 F]fluoronorepinephrine and (-)-[ 11 C]epinephrine, and radiolabelled catecholamine analogues, such as [ 123 I]meta-iodobenzylguanidine, [ 11 C]meta-hydroxyephedrine, [ 18 F]fluorometaraminol, [ 11 C]phenylephrine and meta-[ 76 Br]bromobenzylguanidine. Resistance to metabolism by monoamine oxidase and catechol-O-methyl transferase simplifies the myocardial kinetics of the second group. Both groups of compounds are excellent agents for an overall assessment of sympathetic innervation. Biomathematical modelling of tracer kinetics is complicated by the complexity of the steps governing neuronal uptake, retention and release of these agents as well as by their high neuronal affinity, which leads to partial flow dependence of uptake. Mapping of cardiac parasympathetic neurones is limited by a low density and focal distribution pattern of these neurones in myocardium. Available tracers are derivatives of vesamicol, a molecule that binds to a receptor associated with the vesicular acetylcholine transporter. Compounds like (-)-[ 18 F]fluoroethoxybenzovesamicol display a high degree of non-specific binding in myocardium which restricts their utility for cardiac neuronal imaging. (orig.)

  3. Quantitative assessment of dynamic PET imaging data in cancer imaging.

    Science.gov (United States)

    Muzi, Mark; O'Sullivan, Finbarr; Mankoff, David A; Doot, Robert K; Pierce, Larry A; Kurland, Brenda F; Linden, Hannah M; Kinahan, Paul E

    2012-11-01

    Clinical imaging in positron emission tomography (PET) is often performed using single-time-point estimates of tracer uptake or static imaging that provides a spatial map of regional tracer concentration. However, dynamic tracer imaging can provide considerably more information about in vivo biology by delineating both the temporal and spatial pattern of tracer uptake. In addition, several potential sources of error that occur in static imaging can be mitigated. This review focuses on the application of dynamic PET imaging to measuring regional cancer biologic features and especially in using dynamic PET imaging for quantitative therapeutic response monitoring for cancer clinical trials. Dynamic PET imaging output parameters, particularly transport (flow) and overall metabolic rate, have provided imaging end points for clinical trials at single-center institutions for years. However, dynamic imaging poses many challenges for multicenter clinical trial implementations from cross-center calibration to the inadequacy of a common informatics infrastructure. Underlying principles and methodology of PET dynamic imaging are first reviewed, followed by an examination of current approaches to dynamic PET image analysis with a specific case example of dynamic fluorothymidine imaging to illustrate the approach. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. Practical Considerations for Clinical PET/MR Imaging.

    Science.gov (United States)

    Galgano, Samuel; Viets, Zachary; Fowler, Kathryn; Gore, Lael; Thomas, John V; McNamara, Michelle; McConathy, Jonathan

    2018-01-01

    Clinical PET/MR imaging is currently performed at a number of centers around the world as part of routine standard of care. This article focuses on issues and considerations for a clinical PET/MR imaging program, focusing on routine standard-of-care studies. Although local factors influence how clinical PET/MR imaging is implemented, the approaches and considerations described here intend to apply to most clinical programs. PET/MR imaging provides many more options than PET/computed tomography with diagnostic advantages for certain clinical applications but with added complexity. A recurring theme is matching the PET/MR imaging protocol to the clinical application to balance diagnostic accuracy with efficiency. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. PET imaging for brain function

    International Nuclear Information System (INIS)

    Fukuda, Hiroshi

    2003-01-01

    Described are the principle of PET and its characteristics, imaging of human brain function, mapping of detailed human cerebral functions and PET imaging of nerve transmission. Following compounds labeled by positron emitters are used for PET imaging of brain functions: for blood flow and oxygen metabolism, 15 O-O 2 gas, water and carbon dioxide; for energy metabolism, 18 F-fluorodeoxyglucose; and for nerve transmission functions in receptor binding, transporter, transmitter synthesis and enzyme, 11 C- or 18 F-dopamine, serotonin and their analogues, and acetylcholine analogues. For brain mapping, examples of cognition tasks, results and their statistics are presented with images for blood flow. Nerve transmissions in schizophrenia and Alzheimer disease are imaged with labeled analogues of dopamine and acetylcholine, respectively. PET is becoming more and more important in the field of psychiatric science particularly in the coming society of increasing aged people. (N.I.)

  6. Simultaneous PET/MR imaging in a human brain PET/MR system in 50 patients—Current state of image quality

    International Nuclear Information System (INIS)

    Schwenzer, N.F.; Stegger, L.; Bisdas, S.; Schraml, C.; Kolb, A.; Boss, A.; Müller, M.

    2012-01-01

    Objectives: The present work illustrates the current state of image quality and diagnostic accuracy in a new hybrid BrainPET/MR. Materials and methods: 50 patients with intracranial masses, head and upper neck tumors or neurodegenerative diseases were examined with a hybrid BrainPET/MR consisting of a conventional 3T MR system and an MR-compatible PET insert. Directly before PET/MR, all patients underwent a PET/CT examination with either [ 18 F]-FDG, [ 11 C]-methionine or [ 68 Ga]-DOTATOC. In addition to anatomical MR scans, functional sequences were performed including diffusion tensor imaging (DTI), arterial spin labeling (ASL) and proton-spectroscopy. Image quality score of MR imaging was evaluated using a 4-point-scale. PET data quality was assessed by evaluating FDG-uptake and tumor delineation with [ 11 C]-methionine and [ 68 Ga]-DOTATOC. FDG uptake quantification accuracy was evaluated by means of ROI analysis (right and left frontal and temporo-occipital lobes). The asymmetry indices and ratios between frontal and occipital ROIs were compared. Results: In 45/50 patients, PET/MR examination was successful. Visual analysis revealed a diagnostic image quality of anatomical MR imaging (mean quality score T2 FSE: 1.27 ± 0.54; FLAIR: 1.38 ± 0.61). ASL and proton-spectroscopy was possible in all cases. In DTI, dental artifacts lead to one non-diagnostic dataset (mean quality score DTI: 1.32 ± 0.69; ASL: 1.10 ± 0.31). PET datasets of PET/MR and PET/CT offered comparable tumor delineation with [ 11 C]-methionine; additional lesions were found in 2/8 [ 68 Ga]-DOTATOC-PET in the PET/MR. Mean asymmetry index revealed a high accordance between PET/MR and PET/CT (1.5 ± 2.2% vs. 0.9 ± 3.6%; mean ratio (frontal/parieto-occipital) 0.93 ± 0.08 vs. 0.96 ± 0.05), respectively. Conclusions: The hybrid BrainPET/MR allows for molecular, anatomical and functional imaging with uncompromised MR image quality and a high accordance of PET results between PET/MR and PET

  7. Simultaneous PET/MR imaging in a human brain PET/MR system in 50 patients-Current state of image quality

    Energy Technology Data Exchange (ETDEWEB)

    Schwenzer, N.F., E-mail: nina.schwenzer@med.uni-tuebingen.de [Department of Diagnostic and Interventional Radiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Stegger, L., E-mail: stegger@gmx.net [Department of Nuclear Medicine and European Institute for Molecular Imaging, University of Muenster, Muenster (Germany); Bisdas, S., E-mail: sbisdas@gmail.com [Department of Diagnostic and Interventional Neuroradiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Schraml, C., E-mail: christina.schraml@med.uni-tuebingen.de [Department of Diagnostic and Interventional Radiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Kolb, A., E-mail: armin.kolb@med.uni-tuebingen.de [Laboratory for Preclinical Imaging and Imaging Technology of the Werner Siemens-Foundation, Department of Preclinical Imaging and Radiopharmacy, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Boss, A., E-mail: Andreas.Boss@usz.ch [Department of Diagnostic and Interventional Radiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Institute of Diagnostic and Interventional Radiology, University Hospital Zuerich, Zuerich (Switzerland); Mueller, M., E-mail: mark.mueller@med.uni-tuebingen.de [Department of Nuclear Medicine, Eberhard-Karls University Tuebingen, Tuebingen (Germany); and others

    2012-11-15

    Objectives: The present work illustrates the current state of image quality and diagnostic accuracy in a new hybrid BrainPET/MR. Materials and methods: 50 patients with intracranial masses, head and upper neck tumors or neurodegenerative diseases were examined with a hybrid BrainPET/MR consisting of a conventional 3T MR system and an MR-compatible PET insert. Directly before PET/MR, all patients underwent a PET/CT examination with either [{sup 18}F]-FDG, [{sup 11}C]-methionine or [{sup 68}Ga]-DOTATOC. In addition to anatomical MR scans, functional sequences were performed including diffusion tensor imaging (DTI), arterial spin labeling (ASL) and proton-spectroscopy. Image quality score of MR imaging was evaluated using a 4-point-scale. PET data quality was assessed by evaluating FDG-uptake and tumor delineation with [{sup 11}C]-methionine and [{sup 68}Ga]-DOTATOC. FDG uptake quantification accuracy was evaluated by means of ROI analysis (right and left frontal and temporo-occipital lobes). The asymmetry indices and ratios between frontal and occipital ROIs were compared. Results: In 45/50 patients, PET/MR examination was successful. Visual analysis revealed a diagnostic image quality of anatomical MR imaging (mean quality score T2 FSE: 1.27 {+-} 0.54; FLAIR: 1.38 {+-} 0.61). ASL and proton-spectroscopy was possible in all cases. In DTI, dental artifacts lead to one non-diagnostic dataset (mean quality score DTI: 1.32 {+-} 0.69; ASL: 1.10 {+-} 0.31). PET datasets of PET/MR and PET/CT offered comparable tumor delineation with [{sup 11}C]-methionine; additional lesions were found in 2/8 [{sup 68}Ga]-DOTATOC-PET in the PET/MR. Mean asymmetry index revealed a high accordance between PET/MR and PET/CT (1.5 {+-} 2.2% vs. 0.9 {+-} 3.6%; mean ratio (frontal/parieto-occipital) 0.93 {+-} 0.08 vs. 0.96 {+-} 0.05), respectively. Conclusions: The hybrid BrainPET/MR allows for molecular, anatomical and functional imaging with uncompromised MR image quality and a high accordance

  8. Simultaneous PET and MR imaging

    International Nuclear Information System (INIS)

    Yiping Shao; Cherry, Simon R.; Meadors, Ken; Siegel, Stefan; Silverman, Robert W.; Farahani, Keyvan; Marsden, Paul K.

    1997-01-01

    We have developed a prototype PET detector which is compatible with a clinical MRI system to provide simultaneous PET and MR imaging. This single-slice PET system consists of 48 2x2x10mm 3 LSO crystals in a 38 mm diameter ring configuration that can be placed inside the receiver coil of the MRI system, coupled to three multi-channel photomultipliers housed outside the main magnetic field via 4 m long and 2 mm diameter optical fibres. The PET system exhibits 2 mm spatial resolution, 41% energy resolution at 511 keV and 20 ns timing resolution. Simultaneous PET and MR phantom images were successfully acquired. (author)

  9. Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain

    International Nuclear Information System (INIS)

    Jung, Jin Ho; Choi, Yong; Jung, Jiwoong; Kim, Sangsu; Lim, Hyun Keong; Im, Ki Chun; Oh, Chang Hyun; Park, Hyun-wook; Kim, Kyung Min; Kim, Jong Guk

    2015-01-01

    Purpose: The purpose of this study was to develop a dual-modality positron emission tomography (PET)/magnetic resonance imaging (MRI) with insertable PET for simultaneous PET and MR imaging of the human brain. Methods: The PET detector block was composed of a 4 × 4 matrix of detector modules, each consisting of a 4 × 4 array LYSO coupled to a 4 × 4 Geiger-mode avalanche photodiode (GAPD) array. The PET insert consisted of 18 detector blocks, circularly mounted on a custom-made plastic base to form a ring with an inner diameter of 390 mm and axial length of 60 mm. The PET gantry was shielded with gold-plated conductive fabric tapes with a thickness of 0.1 mm. The charge signals of PET detector transferred via 4 m long flat cables were fed into the position decoder circuit. The flat cables were shielded with a mesh-type aluminum sheet with a thickness of 0.24 mm. The position decoder circuit and field programmable gate array-embedded DAQ modules were enclosed in an aluminum box with a thickness of 10 mm and located at the rear of the MR bore inside the MRI room. A 3-T human MRI system with a Larmor frequency of 123.7 MHz and inner bore diameter of 60 cm was used as the PET/MRI hybrid system. A custom-made radio frequency (RF) coil with an inner diameter of 25 cm was fabricated. The PET was positioned between gradient and the RF coils. PET performance was measured outside and inside the MRI scanner using echo planar imaging, spin echo, turbo spin echo, and gradient echo sequences. MRI performance was also evaluated with and without the PET insert. The stability of the newly developed PET insert was evaluated and simultaneous PET and MR images of a brain phantom were acquired. Results: No significant degradation of the PET performance caused by MR was observed when the PET was operated using various MR imaging sequences. The signal-to-noise ratio of MR images was slightly degraded due to the PET insert installed inside the MR bore while the homogeneity was

  10. Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jin Ho; Choi, Yong, E-mail: ychoi.image@gmail.com; Jung, Jiwoong; Kim, Sangsu; Lim, Hyun Keong; Im, Ki Chun [Department of Electronic Engineering, Sogang University, 35 Baekbeom-ro, Mapo-gu, Seoul 121-742 (Korea, Republic of); Oh, Chang Hyun; Park, Hyun-wook [Department of Electrical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon 305-701 (Korea, Republic of); Kim, Kyung Min; Kim, Jong Guk [Korea Institute of Radiological and Medical Science, 75 Nowon-ro, Nowon-gu, Seoul 139-709 (Korea, Republic of)

    2015-05-15

    Purpose: The purpose of this study was to develop a dual-modality positron emission tomography (PET)/magnetic resonance imaging (MRI) with insertable PET for simultaneous PET and MR imaging of the human brain. Methods: The PET detector block was composed of a 4 × 4 matrix of detector modules, each consisting of a 4 × 4 array LYSO coupled to a 4 × 4 Geiger-mode avalanche photodiode (GAPD) array. The PET insert consisted of 18 detector blocks, circularly mounted on a custom-made plastic base to form a ring with an inner diameter of 390 mm and axial length of 60 mm. The PET gantry was shielded with gold-plated conductive fabric tapes with a thickness of 0.1 mm. The charge signals of PET detector transferred via 4 m long flat cables were fed into the position decoder circuit. The flat cables were shielded with a mesh-type aluminum sheet with a thickness of 0.24 mm. The position decoder circuit and field programmable gate array-embedded DAQ modules were enclosed in an aluminum box with a thickness of 10 mm and located at the rear of the MR bore inside the MRI room. A 3-T human MRI system with a Larmor frequency of 123.7 MHz and inner bore diameter of 60 cm was used as the PET/MRI hybrid system. A custom-made radio frequency (RF) coil with an inner diameter of 25 cm was fabricated. The PET was positioned between gradient and the RF coils. PET performance was measured outside and inside the MRI scanner using echo planar imaging, spin echo, turbo spin echo, and gradient echo sequences. MRI performance was also evaluated with and without the PET insert. The stability of the newly developed PET insert was evaluated and simultaneous PET and MR images of a brain phantom were acquired. Results: No significant degradation of the PET performance caused by MR was observed when the PET was operated using various MR imaging sequences. The signal-to-noise ratio of MR images was slightly degraded due to the PET insert installed inside the MR bore while the homogeneity was

  11. Imaging corn plants with PhytoPET, a modular PET system for plant biology

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.; Kross, B.; McKisson, J.; McKisson, J. E.; Weisenberger, A. G.; Xi, W.; Zorn, C.; Bonito, G.; Howell, C. R.; Reid, C. D.; Crowell, A.; Cumberbatch, L. C.; Topp, C.; Smith, M. F.

    2013-11-01

    PhytoPET is a modular positron emission tomography (PET) system designed specifically for plant imaging. The PhytoPET design allows flexible arrangements of PET detectors based on individual standalone detector modules built from single Hamamatsu H8500 position sensitive photomultiplier tubes and pixelated LYSO arrays. We have used the PhytoPET system to perform preliminary corn plant imaging studies at the Duke University Biology Department Phytotron. Initial evaluation of the PhytoPET system to image the biodistribution of the positron emitting tracer {sup 11}C in corn plants is presented. {sup 11}CO{sub 2} is loaded into corn seedlings by a leaf-labeling cuvette and translocation of {sup 11}C-sugars is imaged by a flexible arrangement of PhytoPET modules on each side. The PhytoPET system successfully images {sup 11}C within corn plants and allows for the dynamic measurement of {sup 11}C-sugar translocation from the leaf to the roots.

  12. Design and evaluation of a mobile bedside PET/SPECT imaging system

    Science.gov (United States)

    Studenski, Matthew Thomas

    Patients confined to an intensive care unit, the emergency room, or a surgical suite are managed without nuclear medicine procedures such as positron emission tomography (PET) or single photon emission computed tomography (SPECT). These studies have diagnostic value which can greatly benefit the physician's treatment of the patient but require that the patient is moved to a scanner. This dissertation examines the feasibility of an economical PET/SPECT system that can be brought to the bedside of an immobile patient for imaging. We chose to focus on cardiac SPECT imaging including perfusion imaging using 99mTc tracers and viability imaging using 18F tracers first because of problems arising from positioning a detector beneath a patient's bed, a requirement for the opposed detector orientation in PET imaging. Second, SPECT imaging acquiring over the anterior 180 degrees of the patient results in reduced attenuation effects due to the heart's location in the anterior portion of the body. Four studies were done to assess the clinical feasibility of the mobile system; 1) the performance of the system was evaluated in SPECT mode at both 140 keV (99mTc tracers) and 511 keV (positron emitting tracers), 2) a dynamic cardiac phantom was used to develop and test image acquisition and processing methods for the system at both energies, 3) a high energy pinhole collimator was designed to reduce the effects of high energy photon penetration through the parallel hole collimator, and 4) we estimated the radiation dose to persons that would be in the vicinity of a patient to ensure that the effective dose is below the regulatory limit. With these studies, we show that the mobile system provides an economical means of bringing nuclear medicine to an immobile patient while staying below the regulatory dose limit to other persons. The system performed well at both 140 keV and 511 keV and provided viable images of a phantom myocardium at both energies. The system does not achieve the

  13. Incremental value of PET and MRI in the evaluation of cardiovascular abnormalities.

    Science.gov (United States)

    Chalian, Hamid; O'Donnell, James K; Bolen, Michael; Rajiah, Prabhakar

    2016-08-01

    The cardiovascular system is affected by a wide range of pathological processes, including neoplastic, inflammatory, ischemic, and congenital aetiology. Magnetic resonance imaging (MRI) and positron emission tomography (PET) are state-of-the-art imaging modalities used in the evaluation of these cardiovascular disorders. MRI has good spatial and temporal resolutions, tissue characterization and multi-planar imaging/reconstruction capabilities, which makes it useful in the evaluation of cardiac morphology, ventricular and valvar function, disease characterization, and evaluation of myocardial viability. FDG-PET provides valuable information on the metabolic activity of the cardiovascular diseases, including ischemia, inflammation, and neoplasm. MRI and FDG-PET can provide complementary information on the evaluation of several cardiovascular disorders. For example, in cardiac masses, FDG-PET provides the metabolic information for indeterminate cardiac masses. MRI can be used for localizing and characterizing abnormal hypermetabolic foci identified incidentally on PET scan and also for local staging. A recent advance in imaging technology has been the development of integrated PET/MRI systems that utilize the advantages of PET and MRI in a single examination. The goal of this manuscript is to provide a comprehensive review on the incremental value of PET and MRI in the evaluation of cardiovascular diseases. • MRI has good spatial and temporal resolutions, tissue characterization, and multi-planar reconstruction • FDG-PET provides valuable information on the metabolic activity of cardiovascular disorders • PET and MRI provide complementary information on the evaluation of cardiovascular disorders.

  14. Development of PET insert for simultaneous PET/MR imaging of human brain

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jiwoong; Choi, Yong; Jung, Jin Ho; Kim, Sangsu; Im, Ki Chun; Lim, Hyun Keong [Molecular Imaging Research & Education (MiRe) Laboratory, Department of Electronic Engineering, Sogang University, Seoul (Korea, Republic of); Oh, Changheun; Park, HyunWook; Cho, Gyuseong [Departments of Electrical Engineering and Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon (Korea, Republic of)

    2014-07-29

    Recently, there has been great interest on the development of combined PET/MR, which is a useful tool for both functional and anatomic imaging. The purpose of this study was to develop a MR compatible PET insert for simultaneous PET and MR imaging of human brain and to evaluate the performance of the hybrid PET-MRI. The PET insert consisted of 18 detector blocks arranged in a ring of 390 mm diameter with 60 mm axial FOV. Each detector block was composed of 4 × 4 matrix of detector modules, each of which consisted of a 4 × 4 array LYSO coupled to a 4 × 4 GAPD array. The PET gantry was shielded with gold-plated conductive fabric tapes. The charge signals of PET detector transferred via 4 m long flat cables were fed into the position decoder circuits (PDCs) and then transferred to FPGA-embedded DAQ modules. The PDCs and DAQ modules were enclosed in an aluminum box and located at the rear of the MR bore inside MRI room. 3-T human MRIs of two different vendors were used to evaluate the MR compatibility of developed PET insert. No significant changes of the PET performance and the homogeneity of MR images caused by the non-compatibility of PET-MRI were observed with the 2 different MRIs. The signal intensities of MR images were slightly degraded (<3.6%) with the both MRI systems. The difference between independently and simultaneously acquired PET images of brain phantom was negligibly small (<4.3%). High quality simultaneous brain PET and MRI of 3 normal volunteers were successfully acquired. Experimental results indicate that the high performance compact and lightweight PET insert for hybrid PET/MRI, which could be utilized with the MRI from various manufactures, can be developed using GAPD arrays and charge signal transmission method proposed in this study.

  15. SPECT and PET imaging in epilepsy

    International Nuclear Information System (INIS)

    Semah, F.

    2007-01-01

    Positron emission tomography (PET) and single photon emission computed tomography (SPECT) imaging are very useful for the management of patients with medically refractory partial epilepsy. Presurgical evaluation of patients with medically refractory partial epilepsy often included PET imaging using FDG. The use of SPECT in these patients adds some more information and gives the clinicians the possibility of having ictal imaging. Furthermore, PET and SPECT imaging are performed to better understand the pathophysiology of epilepsy. (authors)

  16. Clinical PET/CT imaging. Promises and misconceptions

    International Nuclear Information System (INIS)

    Czernin, J.; Auerbach, M.A.

    2005-01-01

    PET/CT is now established as the most important imaging tool in oncology. PET/CT stages and restages cancer with a higher accuracy than PET or CT alone. The sometimes irrational approach to combine state of the art PET with the highest end CT devices should give way to a more reasonable equipment design tailored towards the specific clinical indications in well-defined patient populations. The continuing success of molecular PET/CT now depends more upon advances in molecular imaging with the introduction of targeted imaging probes for individualized therapy approaches in cancer patients and less upon technological advances of imaging equipment. (orig.)

  17. Gated listmode acquisition with the QuadHIDAC animal PET to image mouse hearts

    International Nuclear Information System (INIS)

    Schaefers, K.P.; Lang, N.; Stegger, L.; Schober, O.; Schaefers, M.

    2006-01-01

    Purpose: the aim of this study was to develop ECG and respiratory gating in combination with listmode acquisition for the quadHIDAC small-animal PET scanner. Methods: ECG and respiratory gating was realized with the help of an external trigger device (BioVET) synchronized with the listmode acquisition. Listmode data of a mouse acquisition (injected with 6.5 MBq of 18 F-FDG) were sorted according to three different gating definitions: 12 cardiac gates, 8 respiratory gates and a combination of 8 cardiac and 8 respiratory gates. Images were reconstructed with filtered back-projection (ramp filter), and parameters like left ventricular wall thickness (WT), wall-to-wall separation (WS) and blood to myocardium activity ratios (BMR) were calculated. Results: cardiac gated images show improvement of all parameters (WT 2.6 mm, WS 4.1 mm, BRM 2.3) in diastole compared to ungated images (WT 3.0 mm, WS 3.4 mm, BMR 1.3). Respiratory gating had little effect on calculated parameters. Conclusion: ECG gating with the quadHIDAC can improve myocardial image quality in mice. This could have a major impact on the calculation of an image-derived input function for kinetic modelling. (orig.)

  18. Simultaneous PET/MRI with 13C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification

    DEFF Research Database (Denmark)

    Hansen, Adam E.; Andersen, Flemming L.; Henriksen, Sarah T.

    2016-01-01

    Background: Integrated PET/MRI with hyperpolarized 13C magnetic resonance spectroscopic imaging (13C-MRSI) offers simultaneous, dual-modality metabolic imaging. A prerequisite for the use of simultaneous imaging is the absence of interference between the two modalities. This has been documented...... for a clinical whole-body system using simultaneous 1 H-MRI and PET but never for 13C-MRSI and PET. Here, the feasibility of simultaneous PET and 13C-MRSI as well as hyperpolarized 13C-MRSI in an integrated whole-body PET/MRI hybrid scanner is evaluated using phantom experiments. Methods: Combined PET and 13C......-MRSI phantoms including a NEMA [18F]-FDG phantom, 13C-acetate and 13C-urea sources, and hyperpolarized 13C-pyruvate were imaged repeatedly with PET and/or 13C-MRSI. Measurements evaluated for interference effects included PET activity values in the largest sphere and a background region; total number of PET...

  19. PET-MRI and multimodal cancer imaging

    International Nuclear Information System (INIS)

    Wang Taisong; Zhao Jinhua; Song Jianhua

    2011-01-01

    Multimodality imaging, specifically PET-CT, brought a new perspective into the fields of clinical imaging. Clinical cases have shown that PET-CT has great value in clinical diagnosis and experimental research. But PET-CT still bears some limitations. A major drawback is that CT provides only limited soft tissue contrast and exposes the patient to a significant radiation dose. MRI overcome these limitations, it has excellent soft tissue contrast, high temporal and spatial resolution and no radiation damage. Additionally, since MRI provides also functional information, PET-MRI will show a new direction of multimodality imaging in the future. (authors)

  20. Low-count PET image restoration using sparse representation

    Science.gov (United States)

    Li, Tao; Jiang, Changhui; Gao, Juan; Yang, Yongfeng; Liang, Dong; Liu, Xin; Zheng, Hairong; Hu, Zhanli

    2018-04-01

    In the field of positron emission tomography (PET), reconstructed images are often blurry and contain noise. These problems are primarily caused by the low resolution of projection data. Solving this problem by improving hardware is an expensive solution, and therefore, we attempted to develop a solution based on optimizing several related algorithms in both the reconstruction and image post-processing domains. As sparse technology is widely used, sparse prediction is increasingly applied to solve this problem. In this paper, we propose a new sparse method to process low-resolution PET images. Two dictionaries (D1 for low-resolution PET images and D2 for high-resolution PET images) are learned from a group real PET image data sets. Among these two dictionaries, D1 is used to obtain a sparse representation for each patch of the input PET image. Then, a high-resolution PET image is generated from this sparse representation using D2. Experimental results indicate that the proposed method exhibits a stable and superior ability to enhance image resolution and recover image details. Quantitatively, this method achieves better performance than traditional methods. This proposed strategy is a new and efficient approach for improving the quality of PET images.

  1. Dual-Modality PET/Ultrasound imaging of the Prostate

    Energy Technology Data Exchange (ETDEWEB)

    Huber, Jennifer S.; Moses, William W.; Pouliot, Jean; Hsu, I.C.

    2005-11-11

    Functional imaging with positron emission tomography (PET)will detect malignant tumors in the prostate and/or prostate bed, as well as possibly help determine tumor ''aggressiveness''. However, the relative uptake in a prostate tumor can be so great that few other anatomical landmarks are visible in a PET image. Ultrasound imaging with a transrectal probe provides anatomical detail in the prostate region that can be co-registered with the sensitive functional information from the PET imaging. Imaging the prostate with both PET and transrectal ultrasound (TRUS) will help determine the location of any cancer within the prostate region. This dual-modality imaging should help provide better detection and treatment of prostate cancer. LBNL has built a high performance positron emission tomograph optimized to image the prostate.Compared to a standard whole-body PET camera, our prostate-optimized PET camera has the same sensitivity and resolution, less backgrounds and lower cost. We plan to develop the hardware and software tools needed for a validated dual PET/TRUS prostate imaging system. We also plan to develop dual prostate imaging with PET and external transabdominal ultrasound, in case the TRUS system is too uncomfortable for some patients. We present the design and intended clinical uses for these dual imaging systems.

  2. Dual-Modality PET/Ultrasound imaging of the Prostate

    International Nuclear Information System (INIS)

    Huber, Jennifer S.; Moses, William W.; Pouliot, Jean; Hsu, I.C.

    2005-01-01

    Functional imaging with positron emission tomography (PET)will detect malignant tumors in the prostate and/or prostate bed, as well as possibly help determine tumor ''aggressiveness''. However, the relative uptake in a prostate tumor can be so great that few other anatomical landmarks are visible in a PET image. Ultrasound imaging with a transrectal probe provides anatomical detail in the prostate region that can be co-registered with the sensitive functional information from the PET imaging. Imaging the prostate with both PET and transrectal ultrasound (TRUS) will help determine the location of any cancer within the prostate region. This dual-modality imaging should help provide better detection and treatment of prostate cancer. LBNL has built a high performance positron emission tomograph optimized to image the prostate.Compared to a standard whole-body PET camera, our prostate-optimized PET camera has the same sensitivity and resolution, less backgrounds and lower cost. We plan to develop the hardware and software tools needed for a validated dual PET/TRUS prostate imaging system. We also plan to develop dual prostate imaging with PET and external transabdominal ultrasound, in case the TRUS system is too uncomfortable for some patients. We present the design and intended clinical uses for these dual imaging systems

  3. The synthesis of a new cardiac sympathetic nerve imaging agent N-[11C]CH3-dopamine and biodistribution study

    International Nuclear Information System (INIS)

    Yulin He; Weina Zhou; Xiangcheng Wang; Baoliang Bao; Guojian Zhang; Cheng Wang; Chunmei Wang; Xuemei Wang; Wei Fang

    2014-01-01

    In this study, we synthesized and characterized N-[ 11 C]methyl-dopamine ([ 11 C]MDA) for cardiac sympathetic nerve imaging. [ 11 C]MDA was synthesized by direct N-methylation of dopamine with [ 11 C]methyl iodide and purified by semi-preparation reverse high pressure liquid chromatography (HPLC). The total synthesis time was 45 min including HPLC purification. The radiochemical yields of [ 11 C]MDA was 20 ± 3 %, without decay correction. The radiochemical purity was >98 % and the specific activity was about 50 GBq/mmol. The biological properties of [ 11 C]MDA were evaluated by biodistribution study in normal mice. PET imaging was performed in healthy Chinese mini-swines. Biodistribution study showed that [ 11 C]MDA had high myocardium uptake. PET/CT imaging showed [ 11 C]MDA had clear and symmetrical myocardium uptake, which was blocked obviously by injecting imipramine hydrochloride. [ 11 C]MDA would be a promising candidate of radiotracer for cardiac sympathetic nervous system imaging. (author)

  4. Brain 18F-FDG, 18F-florbtaben PET/CT, 123I-FP-CIT SPECT and cardiac 123I-MBG imaging for diagnosis of a 'cerebral type' of Lewy Body disease

    International Nuclear Information System (INIS)

    Gucht, Axel Van Der; Bélissant, Ophélie; Rabu, Corenti; Cottereau, Anne-Ségolène; Evangelista, Eva; Chalaye, Julia; Bonnot-Lours, Sophie; Fénelon, Gilles; Itti, Emmanuel; De Langavant, Laurent Cleret

    2016-01-01

    A 67-year-old man was referred for fluctuating neuropsychiatric symptoms, featuring depression, delirious episodes, recurrent visual hallucinations and catatonic syndrome associated with cognitive decline. No parkinsonism was found clinically even under neuroleptic treatment. 18 F-FDG PET/CT showed hypometabolism in the posterior associative cortex including the occipital cortex, suggesting Lewy body dementia, but 123 I-FP-CIT SPECT was normal and cardiac 123 I-MIBG imaging showed no signs of sympathetic denervation. Alzheimer's disease was excluded by a normal 18 F-florbetaben PET/CT. This report suggests a rare case of α-synucleinopathy without brainstem involvement, referred to as 'cerebral type' of Lewy body disease

  5. Image Registration for PET/CT and CT Images with Particle Swarm Optimization

    International Nuclear Information System (INIS)

    Lee, Hak Jae; Kim, Yong Kwon; Lee, Ki Sung; Choi, Jong Hak; Kim, Chang Kyun; Moon, Guk Hyun; Joo, Sung Kwan; Kim, Kyeong Min; Cheon, Gi Jeong

    2009-01-01

    Image registration is a fundamental task in image processing used to match two or more images. It gives new information to the radiologists by matching images from different modalities. The objective of this study is to develop 2D image registration algorithm for PET/CT and CT images acquired by different systems at different times. We matched two CT images first (one from standalone CT and the other from PET/CT) that contain affluent anatomical information. Then, we geometrically transformed PET image according to the results of transformation parameters calculated by the previous step. We have used Affine transform to match the target and reference images. For the similarity measure, mutual information was explored. Use of particle swarm algorithm optimized the performance by finding the best matched parameter set within a reasonable amount of time. The results show good agreements of the images between PET/CT and CT. We expect the proposed algorithm can be used not only for PET/CT and CT image registration but also for different multi-modality imaging systems such as SPECT/CT, MRI/PET and so on.

  6. Software-based PET-MR image coregistration: combined PET-MRI for the rest of us

    International Nuclear Information System (INIS)

    Robertson, Matthew S.; Liu, Xinyang; Vyas, Pranav K.; Safdar, Nabile M.; Plishker, William; Zaki, George F.; Shekhar, Raj

    2016-01-01

    With the introduction of hybrid positron emission tomography/magnetic resonance imaging (PET/MRI), a new imaging option to acquire multimodality images with complementary anatomical and functional information has become available. Compared with hybrid PET/computed tomography (CT), hybrid PET/MRI is capable of providing superior anatomical detail while removing the radiation exposure associated with CT. The early adoption of hybrid PET/MRI, however, has been limited. To provide a viable alternative to the hybrid PET/MRI hardware by validating a software-based solution for PET-MR image coregistration. A fully automated, graphics processing unit-accelerated 3-D deformable image registration technique was used to align PET (acquired as PET/CT) and MR image pairs of 17 patients (age range: 10 months-21 years, mean: 10 years) who underwent PET/CT and body MRI (chest, abdomen or pelvis), which were performed within a 28-day (mean: 10.5 days) interval. MRI data for most of these cases included single-station post-contrast axial T1-weighted images. Following registration, maximum standardized uptake value (SUV max ) values observed in coregistered PET (cPET) and the original PET were compared for 82 volumes of interest. In addition, we calculated the target registration error as a measure of the quality of image coregistration, and evaluated the algorithm's performance in the context of interexpert variability. The coregistration execution time averaged 97±45 s. The overall relative SUV max difference was 7% between cPET-MRI and PET/CT. The average target registration error was 10.7±6.6 mm, which compared favorably with the typical voxel size (diagonal distance) of 8.0 mm (typical resolution: 0.66 mm x 0.66 mm x 8 mm) for MRI and 6.1 mm (typical resolution: 3.65 mm x 3.65 mm x 3.27 mm) for PET. The variability in landmark identification did not show statistically significant differences between the algorithm and a typical expert. We have presented a software

  7. Software-based PET-MR image coregistration: combined PET-MRI for the rest of us

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, Matthew S.; Liu, Xinyang; Vyas, Pranav K.; Safdar, Nabile M. [Children' s National Health System, Sheikh Zayed Institute for Pediatric Surgical Innovation, Washington, DC (United States); Plishker, William; Zaki, George F. [IGI Technologies, Inc., College Park, MD (United States); Shekhar, Raj [Children' s National Health System, Sheikh Zayed Institute for Pediatric Surgical Innovation, Washington, DC (United States); IGI Technologies, Inc., College Park, MD (United States)

    2016-10-15

    With the introduction of hybrid positron emission tomography/magnetic resonance imaging (PET/MRI), a new imaging option to acquire multimodality images with complementary anatomical and functional information has become available. Compared with hybrid PET/computed tomography (CT), hybrid PET/MRI is capable of providing superior anatomical detail while removing the radiation exposure associated with CT. The early adoption of hybrid PET/MRI, however, has been limited. To provide a viable alternative to the hybrid PET/MRI hardware by validating a software-based solution for PET-MR image coregistration. A fully automated, graphics processing unit-accelerated 3-D deformable image registration technique was used to align PET (acquired as PET/CT) and MR image pairs of 17 patients (age range: 10 months-21 years, mean: 10 years) who underwent PET/CT and body MRI (chest, abdomen or pelvis), which were performed within a 28-day (mean: 10.5 days) interval. MRI data for most of these cases included single-station post-contrast axial T1-weighted images. Following registration, maximum standardized uptake value (SUV{sub max}) values observed in coregistered PET (cPET) and the original PET were compared for 82 volumes of interest. In addition, we calculated the target registration error as a measure of the quality of image coregistration, and evaluated the algorithm's performance in the context of interexpert variability. The coregistration execution time averaged 97±45 s. The overall relative SUV{sub max} difference was 7% between cPET-MRI and PET/CT. The average target registration error was 10.7±6.6 mm, which compared favorably with the typical voxel size (diagonal distance) of 8.0 mm (typical resolution: 0.66 mm x 0.66 mm x 8 mm) for MRI and 6.1 mm (typical resolution: 3.65 mm x 3.65 mm x 3.27 mm) for PET. The variability in landmark identification did not show statistically significant differences between the algorithm and a typical expert. We have presented a software

  8. PET imaging in multiple sclerosis

    NARCIS (Netherlands)

    Faria, Daniele de Paula; Copray, Sjef; Buchpiguel, Carlos; Dierckx, Rudi; de Vries, Erik

    Positron emission tomography (PET) is a non-invasive technique for quantitative imaging of biochemical and physiological processes in animals and humans. PET uses probes labeled with a radioactive isotope, called PET tracers, which can bind to or be converted by a specific biological target and thus

  9. PET imaging of inflammation

    International Nuclear Information System (INIS)

    Buscombe, J. R.

    2014-01-01

    Inflammatory diseases are common place and often chronic. Most inflammatory cells have increased uptake of glucose which is enhanced in the presence of local cytokines. Therefore, imaging glucose metabolism by the means of 18F-fluoro-deoxy-glucose (FDG) positron emission tomography (PET) holds significant promise in imaging focal inflammation. Most of the work published involved small series of patients with either vasculitis, sarcoid or rheumatoid arthritis. It would appear that FDG PET is a simple and effective technique to identify inflammatory tissue in these conditions. There is even some work to suggest that by comparing baseline and early post therapy scans clinical outcome can be predicted. This would appear to be true with vasculitis as well as retroperitoneal fibrosis. The number of patients in each study is small but the evidence is compelling enough to recommend FDG PET imaging in the routine care of these patients.

  10. Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Izquierdo-Garcia, David [Mount Sinai School of Medicine, Translational and Molecular Imaging Institute, New York, NY (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA (United States); Sawiak, Stephen J. [University of Cambridge, Wolfson Brain Imaging Centre, Cambridge (United Kingdom); Knesaurek, Karin; Machac, Joseph [Mount Sinai School of Medicine, Division of Nuclear Medicine, Department of Radiology, New York, NY (United States); Narula, Jagat [Mount Sinai School of Medicine, Department of Cardiology, Zena and Michael A. Weiner Cardiovascular Institute and Marie-Josee and Henry R. Kravis Cardiovascular Health Center, New York, NY (United States); Fuster, Valentin [Mount Sinai School of Medicine, Department of Cardiology, Zena and Michael A. Weiner Cardiovascular Institute and Marie-Josee and Henry R. Kravis Cardiovascular Health Center, New York, NY (United States); The Centro Nacional de Investigaciones Cardiovasculares (CNIC), Madrid (Spain); Fayad, Zahi A. [Mount Sinai School of Medicine, Translational and Molecular Imaging Institute, New York, NY (United States); Mount Sinai School of Medicine, Department of Cardiology, Zena and Michael A. Weiner Cardiovascular Institute and Marie-Josee and Henry R. Kravis Cardiovascular Health Center, New York, NY (United States); Mount Sinai School of Medicine, Department of Radiology, New York, NY (United States)

    2014-08-15

    The objective of this study was to evaluate the performance of the built-in MR-based attenuation correction (MRAC) included in the combined whole-body Ingenuity TF PET/MR scanner and compare it to the performance of CT-based attenuation correction (CTAC) as the gold standard. Included in the study were 26 patients who underwent clinical whole-body FDG PET/CT imaging and subsequently PET/MR imaging (mean delay 100 min). Patients were separated into two groups: the alpha group (14 patients) without MR coils during PET/MR imaging and the beta group (12 patients) with MR coils present (neurovascular, spine, cardiac and torso coils). All images were coregistered to the same space (PET/MR). The two PET images from PET/MR reconstructed using MRAC and CTAC were compared by voxel-based and region-based methods (with ten regions of interest, ROIs). Lesions were also compared by an experienced clinician. Body mass index and lung density showed significant differences between the alpha and beta groups. Right and left lung densities were also significantly different within each group. The percentage differences in uptake values using MRAC in relation to those using CTAC were greater in the beta group than in the alpha group (alpha group -0.2 ± 33.6 %, R{sup 2} = 0.98, p < 0.001; beta group 10.31 ± 69.86 %, R{sup 2} = 0.97, p < 0.001). In comparison to CTAC, MRAC led to underestimation of the PET values by less than 10 % on average, although some ROIs and lesions did differ by more (including the spine, lung and heart). The beta group (imaged with coils present) showed increased overall PET quantification as well as increased variability compared to the alpha group (imaged without coils). PET data reconstructed with MRAC and CTAC showed some differences, mostly in relation to air pockets, metallic implants and attenuation differences in large bone areas (such as the pelvis and spine) due to the segmentation limitation of the MRAC method. (orig.)

  11. Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging

    International Nuclear Information System (INIS)

    Izquierdo-Garcia, David; Sawiak, Stephen J.; Knesaurek, Karin; Machac, Joseph; Narula, Jagat; Fuster, Valentin; Fayad, Zahi A.

    2014-01-01

    The objective of this study was to evaluate the performance of the built-in MR-based attenuation correction (MRAC) included in the combined whole-body Ingenuity TF PET/MR scanner and compare it to the performance of CT-based attenuation correction (CTAC) as the gold standard. Included in the study were 26 patients who underwent clinical whole-body FDG PET/CT imaging and subsequently PET/MR imaging (mean delay 100 min). Patients were separated into two groups: the alpha group (14 patients) without MR coils during PET/MR imaging and the beta group (12 patients) with MR coils present (neurovascular, spine, cardiac and torso coils). All images were coregistered to the same space (PET/MR). The two PET images from PET/MR reconstructed using MRAC and CTAC were compared by voxel-based and region-based methods (with ten regions of interest, ROIs). Lesions were also compared by an experienced clinician. Body mass index and lung density showed significant differences between the alpha and beta groups. Right and left lung densities were also significantly different within each group. The percentage differences in uptake values using MRAC in relation to those using CTAC were greater in the beta group than in the alpha group (alpha group -0.2 ± 33.6 %, R 2 = 0.98, p 2 = 0.97, p < 0.001). In comparison to CTAC, MRAC led to underestimation of the PET values by less than 10 % on average, although some ROIs and lesions did differ by more (including the spine, lung and heart). The beta group (imaged with coils present) showed increased overall PET quantification as well as increased variability compared to the alpha group (imaged without coils). PET data reconstructed with MRAC and CTAC showed some differences, mostly in relation to air pockets, metallic implants and attenuation differences in large bone areas (such as the pelvis and spine) due to the segmentation limitation of the MRAC method. (orig.)

  12. Dynamic and gated PET. Quantitative imaging of the heart revisited

    International Nuclear Information System (INIS)

    Nekolla, S.G.

    2005-01-01

    This short overview focuses on the basic implementation as well as applications of cardiac PET studies acquired in dynamic and ECG triggered modes. Both acquisition modes are well suited for quantitative analysis and the advantages of such an approach are discussed. An outlook on the measurement of respiratory triggered studies and the new challenges this data presents is provided. In the context of modern PET/CT tomographs with the combination of high sensitivity and morphologic resolution, the promise of list mode acquisition is investigated. The before mentioned acquisition modes are ideal candidates for this technology the utility of which in a clinical setting is briefly discussed. The retrospective generation of dynamic and gated image data (and any combinations) is greatly facilitated with this approach. Finally, a novel presentation mode for the wealth of quantitative information generated by these systems is presented. (orig.)

  13. PET/CT imaging in head and neck tumors

    International Nuclear Information System (INIS)

    Roedel, R.; Palmedo, H.; Reichmann, K.; Reinhardt, M.J.; Biersack, H.J.; Straehler-Pohl, H.J.; Jaeger, U.

    2004-01-01

    To evaluate the usefulness of combined PET/CT examinations for detection of malignant tumors and their metastases in head and neck oncology. 51 patients received whole body scans on a dual modality PET/CT system. CT was performed without i.v. contrast. The results were compared concerning the diagnostic impact of native CT scan on FDG-PET images and the additional value of fused imaging. From 153 lesions were 97 classified as malignant on CT and 136 on FDG/PET images, as suspicious for malignancy in 33 on CT and 7 on FDG-PET and as benign in 23 on CT and 10 on FDG-PET. With combined PET/CT all primary and recurrent tumors could be found, the detection rate in patients with unknown primary tumors was 45%. Compared to PET or CT alone the sensitivity, specifity and accuracy could be significantly improved by means of combined PET/CT. Fused PET/CT imaging with [F18]-FDG and native CT-scanning enables accurate diagnosis in 93% of lesions and 90% of patients with head and neck oncology. (orig.) [de

  14. Acute myocardial infarction associated with intravenous dipyridamole for rubidium-82 PET imaging

    International Nuclear Information System (INIS)

    Marwick, T.H.; Hollman, J.

    1990-01-01

    This report describes the occurrence of chest pain and electrocardiographic features of acute myocardial infarction following intravenous dipyridamole-handgrip stress. Myocardial perfusion imaging (Rb-82 PET) demonstrated a stress-induced perfusion defect. Following failure to respond to medical therapy, urgent cardiac catheterization demonstrated total occlusion of the left anterior descending coronary artery. The vessel was revascularized, with limitation of myocardial damage evidenced by failure to develop anterior Q waves and only modest elevation of cardiac enzyme levels. Complications of intravenous dipyridamole stress are rare, this case constituting the first major problem in over 500 such procedures at this institution. However, this experience demonstrates the importance of vigilant observation during the performance of this technique

  15. Assessment of the diagnostic accuracy of {sup 18}F-FDG PET/CT in prosthetic infective endocarditis and cardiac implantable electronic device infection: comparison of different interpretation criteria

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez-Ballve, Ana; Jesus Perez-Castejon, Maria; Carreras-Delgado, Jose L. [Clinico San Carlos University Hospital, San Carlos Health Research Institute (IdISSC), Complutense University of Madrid, Department of Nuclear Medicine, Madrid (Spain); Delgado-Bolton, Roberto C. [Clinico San Carlos University Hospital, San Carlos Health Research Institute (IdISSC), Complutense University of Madrid, Department of Nuclear Medicine, Madrid (Spain); San Pedro Hospital and Centre for Biomedical Research of La Rioja (CIBIR), University of La Rioja, Department of Diagnostic Imaging (Radiology) and Nuclear Medicine, La Rioja (Spain); Sanchez-Enrique, Cristina; Vilacosta, Isidre; Vivas, David; Olmos, Carmen [Clinico San Carlos University Hospital, Department of Cardiology, Madrid (Spain); Ferrer, Manuel E.F. [Clinico San Carlos University Hospital, Research Unit, Madrid (Spain)

    2016-12-15

    The diagnosis of prosthetic valve (PV) infective endocarditis (IE) and infection of cardiac implantable electronic devices (CIEDs) remains challenging. The aim of this study was to assess the usefulness of {sup 18}F-FDG PET/CT in these patients and analyse the interpretation criteria. We included 41 patients suspected of having IE by the Duke criteria who underwent {sup 18}F-FDG PET/CT. The criteria applied for classifying the findings as positive/negative for IE were: (a) visual analysis of only PET images with attenuation-correction (AC PET images); (b) visual analysis of both AC PET images and PET images without AC (NAC PET images); (c) qualitative analysis of NAC PET images; and (d) semiquantitative analysis of AC PET images. {sup 18}F-FDG PET/CT was considered positive for IE independently of the intensity and distribution of FDG uptake. The gold standard was the Duke pathological criteria (if tissue was available) or the decision of an endocarditis expert team after a minimum 4 months follow-up. We studied 62 areas with suspicion of IE, 28 areas (45 %) showing definite IE and 34 (55 %) showing possible IE. Visual analysis of only AC PET images showed poor diagnostic accuracy (sensitivity 20 %, specificity 57 %). Visual analysis of both AC PET and NAC PET images showed excellent sensitivity (100 %) and intermediate specificity (73 %), focal uptake being more frequently associated with IE. The accuracy of qualitative analysis of NAC PET images depended on the threshold: the maximum sensitivity, specificity and accuracy achieved were 88 %, 80 %, 84 %, respectively. In the semiquantitative analysis of AC PET images, SUVmax was higher in areas of confirmed IE than in those without IE (∇SUVmax 2.2, p < 0.001). When FDG uptake was twice that in the liver, IE was always confirmed, and SUVmax 5.5 was the optimal threshold for IE diagnosis using ROC curve analysis (area under the curve 0.71). The value of {sup 18}F-FDG PET/CT in the diagnosis of suspected IE of PVs

  16. Assessment of the diagnostic accuracy of "1"8F-FDG PET/CT in prosthetic infective endocarditis and cardiac implantable electronic device infection: comparison of different interpretation criteria

    International Nuclear Information System (INIS)

    Jimenez-Ballve, Ana; Jesus Perez-Castejon, Maria; Carreras-Delgado, Jose L.; Delgado-Bolton, Roberto C.; Sanchez-Enrique, Cristina; Vilacosta, Isidre; Vivas, David; Olmos, Carmen; Ferrer, Manuel E.F.

    2016-01-01

    The diagnosis of prosthetic valve (PV) infective endocarditis (IE) and infection of cardiac implantable electronic devices (CIEDs) remains challenging. The aim of this study was to assess the usefulness of "1"8F-FDG PET/CT in these patients and analyse the interpretation criteria. We included 41 patients suspected of having IE by the Duke criteria who underwent "1"8F-FDG PET/CT. The criteria applied for classifying the findings as positive/negative for IE were: (a) visual analysis of only PET images with attenuation-correction (AC PET images); (b) visual analysis of both AC PET images and PET images without AC (NAC PET images); (c) qualitative analysis of NAC PET images; and (d) semiquantitative analysis of AC PET images. "1"8F-FDG PET/CT was considered positive for IE independently of the intensity and distribution of FDG uptake. The gold standard was the Duke pathological criteria (if tissue was available) or the decision of an endocarditis expert team after a minimum 4 months follow-up. We studied 62 areas with suspicion of IE, 28 areas (45 %) showing definite IE and 34 (55 %) showing possible IE. Visual analysis of only AC PET images showed poor diagnostic accuracy (sensitivity 20 %, specificity 57 %). Visual analysis of both AC PET and NAC PET images showed excellent sensitivity (100 %) and intermediate specificity (73 %), focal uptake being more frequently associated with IE. The accuracy of qualitative analysis of NAC PET images depended on the threshold: the maximum sensitivity, specificity and accuracy achieved were 88 %, 80 %, 84 %, respectively. In the semiquantitative analysis of AC PET images, SUVmax was higher in areas of confirmed IE than in those without IE (∇SUVmax 2.2, p < 0.001). When FDG uptake was twice that in the liver, IE was always confirmed, and SUVmax 5.5 was the optimal threshold for IE diagnosis using ROC curve analysis (area under the curve 0.71). The value of "1"8F-FDG PET/CT in the diagnosis of suspected IE of PVs and CIEDs is

  17. PET/MR Imaging in Vascular Disease

    DEFF Research Database (Denmark)

    Ripa, Rasmus Sejersten; Pedersen, Sune Folke; Kjær, Andreas

    2016-01-01

    For imaging of atherosclerotic disease, lumenography using computed tomography, ultrasonography, or invasive angiography is still the backbone of evaluation. However, these methods are less effective to predict the likelihood of future thromboembolic events caused by vulnerability of plaques. PET...... through data and arguments that support increased use of PET/MR imaging in atherosclerotic imaging....

  18. Effect of motion-induced PET-CT misalignment on cardiac function and myocardial blood flow measured using dynamic 15O-water PET

    DEFF Research Database (Denmark)

    Lubberink, Mark; Ebrahimi, M; Harms, Hans

    -CT misalignment on MBF, transmural MBF (MBFt), perfusable tissue fraction (PTF), cardiac output (CO), stroke volume (SV) and left-ventricular ejection fraction (LVEF) based on dynamic 15O-water scans. Methods: 10 patients underwent 6 min PET scans after injection of 400 MBq 15O-water at rest and during adenosine......Aim: Motion-induced PET-CT misalignment artifacts are common in myocardial blood flow (MBF) measurements with 82Rb and 13N-ammonia. For 15O-water, MBF is based on the clearance rate rather than uptake of the tracer. The clearance rate is determined by the shape of the time-activity curve, not its...... amplitude, and is thus not affected by attenuation correction errors. Hence, misalignment is hypothesized not to affect 15O-water-based MBF to any large extent, but it may affect cardiac function measures derived from 15O-water scans. The aim of the present work was to assess the effect of PET...

  19. An attenuation correction method for PET/CT images

    International Nuclear Information System (INIS)

    Ue, Hidenori; Yamazaki, Tomohiro; Haneishi, Hideaki

    2006-01-01

    In PET/CT systems, accurate attenuation correction can be achieved by creating an attenuation map from an X-ray CT image. On the other hand, respiratory-gated PET acquisition is an effective method for avoiding motion blurring of the thoracic and abdominal organs caused by respiratory motion. In PET/CT systems employing respiratory-gated PET, using an X-ray CT image acquired during breath-holding for attenuation correction may have a large effect on the voxel values, especially in regions with substantial respiratory motion. In this report, we propose an attenuation correction method in which, as the first step, a set of respiratory-gated PET images is reconstructed without attenuation correction, as the second step, the motion of each phase PET image from the PET image in the same phase as the CT acquisition timing is estimated by the previously proposed method, as the third step, the CT image corresponding to each respiratory phase is generated from the original CT image by deformation according to the motion vector maps, and as the final step, attenuation correction using these CT images and reconstruction are performed. The effectiveness of the proposed method was evaluated using 4D-NCAT phantoms, and good stability of the voxel values near the diaphragm was observed. (author)

  20. Imaging cardiac amyloidosis: a pilot study using 18F-florbetapir positron emission tomography

    International Nuclear Information System (INIS)

    Dorbala, Sharmila; Vangala, Divya; Semer, James; Strader, Christopher; Bruyere, John R.; Moore, Stephen C.; Di Carli, Marcelo F.; Falk, Rodney H.

    2014-01-01

    Cardiac amyloidosis, a restrictive heart disease with high mortality and morbidity, is underdiagnosed due to limited targeted diagnostic imaging. The primary aim of this study was to evaluate the utility of 18 F-florbetapir for imaging cardiac amyloidosis. We performed a pilot study of cardiac 18 F-florbetapir PET in 14 subjects: 5 control subjects without amyloidosis and 9 subjects with documented cardiac amyloidosis. Standardized uptake values (SUV) of 18 F-florbetapir in the left ventricular (LV) myocardium, blood pool, liver, and vertebral bone were determined. A 18 F-florbetapir retention index (RI) was computed. Mean LV myocardial SUVs, target-to-background ratio (TBR, myocardial/blood pool SUV ratio) and myocardial-to-liver SUV ratio between 0 and 30 min were calculated. Left and right ventricular myocardial uptake of 18 F-florbetapir were noted in all the amyloid subjects and in none of the control subjects. The RI, TBR, LV myocardial SUV and LV myocardial to liver SUV ratio were all significantly higher in the amyloidosis subjects than in the control subjects (RI median 0.043 min -1 , IQR 0.034 - 0.051 min -1 , vs. 0.023 min -1 , IQR 0.015 - 0.025 min -1 , P = 0.002; TBR 1.84, 1.64 - 2.50, vs. 1.26, IQR 0.91 - 1.36, P = 0.001; LV myocardial SUV 3.84, IQR 1.87 - 5.65, vs. 1.35, IQR 1.17 - 2.28, P = 0.029; ratio of LV myocardial to liver SUV 0.67, IQR 0.44 - 1.64, vs. 0.18, IQR 0.15 - 0.35, P = 0.004). The myocardial RI, TBR and myocardial to liver SUV ratio also distinguished the control subjects from subjects with transthyretin and those with light chain amyloid. 18 F-Florbetapir PET may be a promising technique to image light chain and transthyretin cardiac amyloidosis. Its role in diagnosing amyloid in other organ systems and in assessing response to therapy needs to be further studied. (orig.)

  1. Multi-technique hybrid imaging in PET/CT and PET/MR: what does the future hold?

    International Nuclear Information System (INIS)

    Galiza Barbosa, F. de; Delso, G.; Voert, E.E.G.W. ter; Huellner, M.W.; Herrmann, K.; Veit-Haibach, P.

    2016-01-01

    Integrated positron-emission tomography and computed tomography (PET/CT) is one of the most important imaging techniques to have emerged in oncological practice in the last decade. Hybrid imaging, in general, remains a rapidly growing field, not only in developing countries, but also in western industrialised healthcare systems. A great deal of technological development and research is focused on improving hybrid imaging technology further and introducing new techniques, e.g., integrated PET and magnetic resonance imaging (PET/MRI). Additionally, there are several new PET tracers on the horizon, which have the potential to broaden clinical applications in hybrid imaging for diagnosis as well as therapy. This article aims to highlight some of the major technical and clinical advances that are currently taking place in PET/CT and PET/MRI that will potentially maintain the position of hybrid techniques at the forefront of medical imaging technologies.

  2. PET/CT. Dose-escalated image fusion?

    International Nuclear Information System (INIS)

    Brix, G.; Beyer, T.

    2005-01-01

    Clinical studies demonstrate a gain in diagnostic accuracy by employing combined PET/CT instead of separate CT and PET imaging. However, whole-body PET/CT examinations result in a comparatively high radiation burden to patients and thus require a proper justification and optimization to avoid repeated exposure or over-exposure of patients. This review article summarizes relevant data concerning radiation exposure of patients resulting from the different components of a combined PET/CT examination and presents different imaging strategies that can help to balance the diagnostic needs and the radiation protection requirements. In addition various dose reduction measures are discussed, some of which can be adopted from CT practice, while others mandate modifications to the existing hard- and software of PET/CT systems. (orig.)

  3. Non-FDG PET imaging of brain tumors

    Institute of Scientific and Technical Information of China (English)

    HUANG Zemin; GUAN Yihui; ZUO Chuantao; ZHANG Zhengwei; XUE Fangping; LIN Xiangtong

    2007-01-01

    Due to relatively high uptake of glucose in the brain cortex, the use of FDG PET imaging is greatly limited in brain tumor imaging, especially for low-grade gliomas and some metastatic tumours. More and more tracers with higher specificity were developed lately for brain tumor imaging. There are 3 main types of non-FDG PET tracers:amino acid tracers, choline tracers and nucleic acid tracers. These tracers are now widely applied in many aspects of brain tumor imaging. This article summarized the general use of non-FDG PET in different aspects of brain tumor imaging.

  4. Remote transfer of PET images by internet

    International Nuclear Information System (INIS)

    Zuo Chuantao; Lin Xiangtong; Guan Yihui; Zhao Jun

    2003-01-01

    The methodology of PET image remote transfer by Internet has been explored. The original images were got with ECAT EXACT HR + PET, and then converted to Dicom format by Mview software. The Dicom images were transferred via Internet. Thus the PET images were transferred via Internet successfully. The ideal images were obtained away from 8 km. The transfer time of brain and whole body image was (37±3)s and (245±10)s respectively, while the transfer rate was (34.7±2.8) kbyte/s and (34.4±1.5)kbyte/s, respectively. The results showed that the remote transfer via Internet was feasible and practical

  5. Clinical PET/MR Imaging in Oncology

    DEFF Research Database (Denmark)

    Kjær, Andreas; Torigian, Drew A.

    2016-01-01

    . The question, therefore, arises regarding what the future clinical applications of PET/MR imaging will be. In this article, the authors discuss ways in which PET/MR imaging may be used in future applications that justify the added cost, predominantly focusing on oncologic applications. The authors suggest...

  6. Dynamic PET Image reconstruction for parametric imaging using the HYPR kernel method

    Science.gov (United States)

    Spencer, Benjamin; Qi, Jinyi; Badawi, Ramsey D.; Wang, Guobao

    2017-03-01

    Dynamic PET image reconstruction is a challenging problem because of the ill-conditioned nature of PET and the lowcounting statistics resulted from short time-frames in dynamic imaging. The kernel method for image reconstruction has been developed to improve image reconstruction of low-count PET data by incorporating prior information derived from high-count composite data. In contrast to most of the existing regularization-based methods, the kernel method embeds image prior information in the forward projection model and does not require an explicit regularization term in the reconstruction formula. Inspired by the existing highly constrained back-projection (HYPR) algorithm for dynamic PET image denoising, we propose in this work a new type of kernel that is simpler to implement and further improves the kernel-based dynamic PET image reconstruction. Our evaluation study using a physical phantom scan with synthetic FDG tracer kinetics has demonstrated that the new HYPR kernel-based reconstruction can achieve a better region-of-interest (ROI) bias versus standard deviation trade-off for dynamic PET parametric imaging than the post-reconstruction HYPR denoising method and the previously used nonlocal-means kernel.

  7. Investigation progress of PET reporter gene imaging

    International Nuclear Information System (INIS)

    Chen Yumei; Huang Gang

    2006-01-01

    Molecular imaging for gene therapy and gene expression has been more and more attractive, while the use of gene therapy has been widely investigated and intense research have allowed it to the clinical setting in the last two-decade years. In vivo imaging with positron emission tomography (PET) by combination of appropriate PET reporter gene and PET reporter probe could provide qualitative and quantitative information for gene therapy. PET imaging could also obtain some valuable parameters not available by other techniques. This technology is useful to understand the process and development of gene therapy and how to apply it into clinical practice in the future. (authors)

  8. Cardiac hybrid imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gaemperli, Oliver [University Hospital Zurich, Cardiac Imaging, Zurich (Switzerland); University Hospital Zurich, Nuclear Cardiology, Cardiovascular Center, Zurich (Switzerland); Kaufmann, Philipp A. [University Hospital Zurich, Cardiac Imaging, Zurich (Switzerland); Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland)

    2014-05-15

    Hybrid cardiac single photon emission computed tomography (SPECT)/CT imaging allows combined assessment of anatomical and functional aspects of cardiac disease. In coronary artery disease (CAD), hybrid SPECT/CT imaging allows detection of coronary artery stenosis and myocardial perfusion abnormalities. The clinical value of hybrid imaging has been documented in several subsets of patients. In selected groups of patients, hybrid imaging improves the diagnostic accuracy to detect CAD compared to the single imaging techniques. Additionally, this approach facilitates functional interrogation of coronary stenoses and guidance with regard to revascularization procedures. Moreover, the anatomical information obtained from CT coronary angiography or coronary artery calcium scores (CACS) adds prognostic information over perfusion data from SPECT. The use of cardiac hybrid imaging has been favoured by the dissemination of dedicated hybrid systems and the release of dedicated image fusion software, which allow simple patient throughput for hybrid SPECT/CT studies. Further technological improvements such as more efficient detector technology to allow for low-radiation protocols, ultra-fast image acquisition and improved low-noise image reconstruction algorithms will be instrumental to further promote hybrid SPECT/CT in research and clinical practice. (orig.)

  9. A study of artefacts in simultaneous PET and MR imaging using a prototype MR compatible PET scanner

    International Nuclear Information System (INIS)

    Slates, R.B.; Farahani, K.; Marsden, P.K.; Taylor, J.; Summers, P.E.; Williams, S.; Beech, J.

    1999-01-01

    We have assessed the possibility of artefacts that can arise in attempting to perform simultaneous positron emission tomography (PET) and magnetic resonance imaging (MRI) using a small prototype MR compatible PET scanner (McPET). In these experiments, we examine MR images for any major artefacts or loss in image quality due to inhomogeneities in the magnetic field, radiofrequency interference or susceptibility effects caused by operation of the PET system inside the MR scanner. In addition, possible artefacts in the PET images caused by the static and time-varying magnetic fields or radiofrequency interference from the MR system were investigated. Biological tissue and a T 2 -weighted spin echo sequence were used to examine susceptibility artefacts due to components of the McPET scanner (scintillator, optical fibres) situated in the MR field of view. A range of commonly used MR pulse sequences was studied while acquiring PET data to look for possible artefacts in either the PET or MR images. Other than a small loss in signal-to-noise using gradient echo sequences, there was no significant interaction between the two imaging systems. Simultaneous PET and MR imaging of simple phantoms was also carried out in different MR systems with field strengths ranging from 0.2 to 4.7 T. The results of these studies demonstrate that it is possible to acquire PET and MR images simultaneously, without any significant artefacts or loss in image quality, using our prototype MR compatible PET scanner. (author)

  10. Simultaneous PET/MRI with (13)C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification.

    Science.gov (United States)

    Hansen, Adam E; Andersen, Flemming L; Henriksen, Sarah T; Vignaud, Alexandre; Ardenkjaer-Larsen, Jan H; Højgaard, Liselotte; Kjaer, Andreas; Klausen, Thomas L

    2016-12-01

    Integrated PET/MRI with hyperpolarized (13)C magnetic resonance spectroscopic imaging ((13)C-MRSI) offers simultaneous, dual-modality metabolic imaging. A prerequisite for the use of simultaneous imaging is the absence of interference between the two modalities. This has been documented for a clinical whole-body system using simultaneous (1)H-MRI and PET but never for (13)C-MRSI and PET. Here, the feasibility of simultaneous PET and (13)C-MRSI as well as hyperpolarized (13)C-MRSI in an integrated whole-body PET/MRI hybrid scanner is evaluated using phantom experiments. Combined PET and (13)C-MRSI phantoms including a NEMA [(18)F]-FDG phantom, (13)C-acetate and (13)C-urea sources, and hyperpolarized (13)C-pyruvate were imaged repeatedly with PET and/or (13)C-MRSI. Measurements evaluated for interference effects included PET activity values in the largest sphere and a background region; total number of PET trues; and (13)C-MRSI signal-to-noise ratio (SNR) for urea and acetate phantoms. Differences between measurement conditions were evaluated using t tests. PET and (13)C-MRSI data acquisition could be performed simultaneously without any discernible artifacts. The average difference in PET activity between acquisitions with and without simultaneous (13)C-MRSI was 0.83 (largest sphere) and -0.76 % (background). The average difference in net trues was -0.01 %. The average difference in (13)C-MRSI SNR between acquisitions with and without simultaneous PET ranged from -2.28 to 1.21 % for all phantoms and measurement conditions. No differences were significant. The system was capable of (13)C-MRSI of hyperpolarized (13)C-pyruvate. Simultaneous PET and (13)C-MRSI in an integrated whole-body PET/MRI hybrid scanner is feasible. Phantom experiments showed that possible interference effects introduced by acquiring data from the two modalities simultaneously are small and non-significant. Further experiments can now investigate the benefits of simultaneous PET and

  11. Do carotid MR surface coils affect PET quantification in PET/MR imaging?

    International Nuclear Information System (INIS)

    Willemink, Martin J; Eldib, Mootaz; Leiner, Tim; Fayad, Zahi A; Mani, Venkatesh

    2015-01-01

    To evaluate the effect of surface coils for carotid MR imaging on PET quantification in a clinical simultaneous whole-body PET/MR scanner. A cylindrical phantom was filled with a homogeneous 2L water-FDG mixture at a starting dose of 301.2MBq. Clinical PET/MR and PET/CT systems were used to acquire PET-data without a coil (reference standard) and with two carotid MRI coils (Siemens Special Purpose 8-Channel and Machnet 4-Channel Phased Array). PET-signal attenuation was evaluated with Osirix using 51 (PET/MR) and 37 (PET/CT) circular ROIs. Mean and maximum standardized uptake values (SUVs) were quantified for each ROI. Furthermore, SUVs of PET/MR and PET/CT were compared. For validation, a patient was scanned with an injected dose of 407.7MBq on both a PET/CT and a PET/MR system without a coil and with both coils. PET/MR underestimations were -2.2% (Siemens) and -7.8% (Machnet) for SUVmean, and -1.2% (Siemens) and -3.3% (Machnet) for SUVmax, respectively. For PET/CT, underestimations were -1.3% (Siemens) and -1.4% (Machnet) for SUVmean and -0.5% (both Siemens and Machnet) for SUVmax, respectively using no coil data as reference. Except for PET/CT SUVmax values all differences were significant. SUVs differed significantly between PET/MR and PET/CT with SUVmean values of 0.51-0.55 for PET/MR and 0.68-0.69 for PET/CT, respectively. The patient examination showed that median SUVmean values measured in the carotid arteries decreased from 0.97 without a coil to 0.96 (Siemens) and 0.88 (Machnet). Carotid surface coils do affect attenuation correction in both PET/MR and PET/CT imaging. Furthermore, SUVs differed significantly between PET/MR and PET/CT.

  12. Deep Learning MR Imaging-based Attenuation Correction for PET/MR Imaging.

    Science.gov (United States)

    Liu, Fang; Jang, Hyungseok; Kijowski, Richard; Bradshaw, Tyler; McMillan, Alan B

    2018-02-01

    Purpose To develop and evaluate the feasibility of deep learning approaches for magnetic resonance (MR) imaging-based attenuation correction (AC) (termed deep MRAC) in brain positron emission tomography (PET)/MR imaging. Materials and Methods A PET/MR imaging AC pipeline was built by using a deep learning approach to generate pseudo computed tomographic (CT) scans from MR images. A deep convolutional auto-encoder network was trained to identify air, bone, and soft tissue in volumetric head MR images coregistered to CT data for training. A set of 30 retrospective three-dimensional T1-weighted head images was used to train the model, which was then evaluated in 10 patients by comparing the generated pseudo CT scan to an acquired CT scan. A prospective study was carried out for utilizing simultaneous PET/MR imaging for five subjects by using the proposed approach. Analysis of covariance and paired-sample t tests were used for statistical analysis to compare PET reconstruction error with deep MRAC and two existing MR imaging-based AC approaches with CT-based AC. Results Deep MRAC provides an accurate pseudo CT scan with a mean Dice coefficient of 0.971 ± 0.005 for air, 0.936 ± 0.011 for soft tissue, and 0.803 ± 0.021 for bone. Furthermore, deep MRAC provides good PET results, with average errors of less than 1% in most brain regions. Significantly lower PET reconstruction errors were realized with deep MRAC (-0.7% ± 1.1) compared with Dixon-based soft-tissue and air segmentation (-5.8% ± 3.1) and anatomic CT-based template registration (-4.8% ± 2.2). Conclusion The authors developed an automated approach that allows generation of discrete-valued pseudo CT scans (soft tissue, bone, and air) from a single high-spatial-resolution diagnostic-quality three-dimensional MR image and evaluated it in brain PET/MR imaging. This deep learning approach for MR imaging-based AC provided reduced PET reconstruction error relative to a CT-based standard within the brain compared

  13. The continual innovation of commercial PET/CT solutions in nuclear cardiology: Siemens Healthineers.

    Science.gov (United States)

    Bendriem, Bernard; Reed, Jessie; McCullough, Kathryn; Khan, Mohammad Raza; Smith, Anne M; Thomas, Damita; Long, Misty

    2018-04-10

    Cardiac PET/CT is an evolving, non-invasive imaging modality that impacts patient management in many clinical scenarios. Beyond offering the capability to assess myocardial perfusion, inflammatory cardiac pathologies, and myocardial viability, cardiac PET/CT also allows for the non-invasive quantitative assessment of myocardial blood flow (MBF) and myocardial flow reserve (MFR). Recognizing the need for an enhanced comprehension of coronary physiology, Siemens Healthineers implemented a sophisticated solution for the calculation of MBF and MFR in 2009. As a result, each aspect of their innovative scanner and image-processing technology seamlessly integrates into an efficient, easy-to-use workflow for everyday clinical use that maximizes the number of patients who potentially benefit from this imaging modality.

  14. Comparison of the prognostic value of SPECT after nitrate administration and metabolic imaging by PET in patients with ischaemic left ventricular dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Sorrentino, Anna R.; Acampa, Wanda; Mainolfi, Ciro; Salvatore, Marco; Cuocolo, Alberto [University Federico II, Department of Biomorphological and Functional Sciences, Institute of Biostructures and Bioimages of the National Council of Research, Naples (Italy); Petretta, Mario [University Federico II, Department of Internal Medicine, Cardiovascular and Immunological Sciences, Naples (Italy)

    2007-04-15

    We compared the prognostic value of {sup 99m}Tc-tetrofosmin single-photon emission computed tomography (SPECT) after nitrate administration and positron emission tomography (PET) with {sup 18}F-fluorodeoxyglucose (FDG) in patients with ischaemic left ventricular (LV) dysfunction. Eighty-nine patients with previous myocardial infarction and LV dysfunction (LV ejection fraction 33 {+-} 10%) underwent {sup 99m}Tc-tetrofosmin SPECT under control conditions (baseline) and after sublingual administration of 10 mg of isosorbide dinitrate (nitrate). Within 1 week, all patients underwent PET imaging with {sup 18}F-FDG. Four patients were excluded because of inadequate FDG uptake caused by severe diabetes. Follow-up data were obtained by phone contact with patients and by review of hospital or physicians' records. Cardiac death, myocardial infarction and late revascularisation for unstable angina were considered as events. Follow-up data were not available in three patients. Follow-up was 96% complete at a mean period of 29 {+-} 19 months. At baseline SPECT, 59 (72%) patients had evidence of viable myocardium, while 23 did not. Of these latter patients, 12 (52%) demonstrated viable myocardium after nitrate and 13 (56%) had preserved metabolic activity. Cardiac events (cardiac death, myocardial infarction and late revascularisation for unstable angina) occurred in 24 (29%) patients. Event-free survival was similar in patients with and patients without viable myocardium at baseline SPECT (p = 0.8). In contrast, event-free survival was lower in patients with viable myocardium at nitrate SPECT and PET compared to those without viable myocardium (both p<0.05). In patients with ischaemic LV dysfunction, the prognostic value of SPECT imaging after nitrate is comparable to that of PET metabolic imaging. (orig.)

  15. LOR-interleaving image reconstruction for PET imaging with fractional-crystal collimation

    International Nuclear Information System (INIS)

    Li, Yusheng; Matej, Samuel; Karp, Joel S; Metzler, Scott D

    2015-01-01

    Positron emission tomography (PET) has become an important modality in medical and molecular imaging. However, in most PET applications, the resolution is still mainly limited by the physical crystal sizes or the detector’s intrinsic spatial resolution. To achieve images with better spatial resolution in a central region of interest (ROI), we have previously proposed using collimation in PET scanners. The collimator is designed to partially mask detector crystals to detect lines of response (LORs) within fractional crystals. A sequence of collimator-encoded LORs is measured with different collimation configurations. This novel collimated scanner geometry makes the reconstruction problem challenging, as both detector and collimator effects need to be modeled to reconstruct high-resolution images from collimated LORs. In this paper, we present a LOR-interleaving (LORI) algorithm, which incorporates these effects and has the advantage of reusing existing reconstruction software, to reconstruct high-resolution images for PET with fractional-crystal collimation. We also develop a 3D ray-tracing model incorporating both the collimator and crystal penetration for simulations and reconstructions of the collimated PET. By registering the collimator-encoded LORs with the collimator configurations, high-resolution LORs are restored based on the modeled transfer matrices using the non-negative least-squares method and EM algorithm. The resolution-enhanced images are then reconstructed from the high-resolution LORs using the MLEM or OSEM algorithm. For validation, we applied the LORI method to a small-animal PET scanner, A-PET, with a specially designed collimator. We demonstrate through simulated reconstructions with a hot-rod phantom and MOBY phantom that the LORI reconstructions can substantially improve spatial resolution and quantification compared to the uncollimated reconstructions. The LORI algorithm is crucial to improve overall image quality of collimated PET, which

  16. Clinical evaluation of PET image quality as a function of acquisition time in a new TOF-PET/MR compared to TOF-PET/CT - initial results

    International Nuclear Information System (INIS)

    Zeimpekis, Konstantinos; Huellner, Martin; De Galiza Barbosa, Felipe; Ter Voert, Edwin; Davison, Helen; Delso, Gaspar; Veit-Haibach, Patrick

    2015-01-01

    The recently available integrated PET/MR imaging can offer significant additional advances in clinical imaging. The purpose of this study was to compare the PET performance between a PET/CT scanner and an integrated TOF-PET/MR scanner concerning image quality parameters and quantification in terms of SUV as a function of acquisition time (a surrogate of dose). Five brain and five whole body patients were included in the study. The PET/CT scan was used as a reference and the PET/MR acquisition time was consecutively adjusted, taking into account the decay between the scans in order to expose both systems to the same amount of emitted signal. The acquisition times were then retrospectively reduced to assess the performance of the PET/MRI for lower count rates. Image quality, image sharpness, artifacts and noise were evaluated. SUV measurements were taken in the liver and in white matter to compare quantification. Quantitative evaluation showed good correlation between PET/CT and PET/MR brain SUVs. Liver correlation was lower, with uptake underestimation in PET/MR, partially justified by bio-redistribution. The clinical evaluation showed that PET/MR offers higher image quality and sharpness with lower levels of noise and artefacts compared to PET/CT with reduced acquisition times for whole body scans, while for brain scans there is no significant difference. The PET-component of the TOF-PET/MR showed higher image quality compared to PET/CT as tested with reduced imaging times. However, these results account mainly for body imaging, while no significant difference were found in brain imaging. This overall higher image quality suggests that the acquisition time or injected activity can be reduced by at least 37% on the PET/MR scanner.

  17. Clinical evaluation of PET image quality as a function of acquisition time in a new TOF-PET/MR compared to TOF-PET/CT - initial results

    Energy Technology Data Exchange (ETDEWEB)

    Zeimpekis, Konstantinos; Huellner, Martin; De Galiza Barbosa, Felipe; Ter Voert, Edwin; Davison, Helen; Delso, Gaspar; Veit-Haibach, Patrick [Nuclear Medicine, University Hospital Zurich (Switzerland)

    2015-05-18

    The recently available integrated PET/MR imaging can offer significant additional advances in clinical imaging. The purpose of this study was to compare the PET performance between a PET/CT scanner and an integrated TOF-PET/MR scanner concerning image quality parameters and quantification in terms of SUV as a function of acquisition time (a surrogate of dose). Five brain and five whole body patients were included in the study. The PET/CT scan was used as a reference and the PET/MR acquisition time was consecutively adjusted, taking into account the decay between the scans in order to expose both systems to the same amount of emitted signal. The acquisition times were then retrospectively reduced to assess the performance of the PET/MRI for lower count rates. Image quality, image sharpness, artifacts and noise were evaluated. SUV measurements were taken in the liver and in white matter to compare quantification. Quantitative evaluation showed good correlation between PET/CT and PET/MR brain SUVs. Liver correlation was lower, with uptake underestimation in PET/MR, partially justified by bio-redistribution. The clinical evaluation showed that PET/MR offers higher image quality and sharpness with lower levels of noise and artefacts compared to PET/CT with reduced acquisition times for whole body scans, while for brain scans there is no significant difference. The PET-component of the TOF-PET/MR showed higher image quality compared to PET/CT as tested with reduced imaging times. However, these results account mainly for body imaging, while no significant difference were found in brain imaging. This overall higher image quality suggests that the acquisition time or injected activity can be reduced by at least 37% on the PET/MR scanner.

  18. PET imaging in pediatric oncology

    International Nuclear Information System (INIS)

    Shulkin, B.L.

    2004-01-01

    High-quality PET imaging of pediatric patients is challenging and requires attention to issues commonly encountered in the practice of pediatric nuclear medicine, but uncommon to the imaging of adult patients. These include intravenous access, fasting, sedation, consent, and clearance of activity from the urinary tract. This paper discusses some technical differences involved in pediatric PET to enhance the quality of scans and assure the safety and comfort of pediatric patients. (orig.)

  19. PET imaging in pediatric neuroradiology: current and future applications

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sunhee [Children' s Hospital of Pittsburgh of UPMC, Department of Radiology, Pittsburgh, PA (United States); Salamon, Noriko [UCLA David Geffen School of Medicine at UCLA, Department of Radiology, Ronald Reagan UCLA Medical Center, Los Angeles, CA (United States); Jackson, Hollie A.; Blueml, Stefan [Keck School of Medicine of USC, Department of Radiology, Childrens Hospital Los Angeles, Los Angeles, CA (United States); Panigrahy, Ashok [Children' s Hospital of Pittsburgh of UPMC, Department of Radiology, Pittsburgh, PA (United States); Keck School of Medicine of USC, Department of Radiology, Childrens Hospital Los Angeles, Los Angeles, CA (United States)

    2010-01-15

    Molecular imaging with positron emitting tomography (PET) is widely accepted as an essential part of the diagnosis and evaluation of neoplastic and non-neoplastic disease processes. PET has expanded its role from the research domain into clinical application for oncology, cardiology and neuropsychiatry. More recently, PET is being used as a clinical molecular imaging tool in pediatric neuroimaging. PET is considered an accurate and noninvasive method to study brain activity and to understand pediatric neurological disease processes. In this review, specific examples of the clinical use of PET are given with respect to pediatric neuroimaging. The current use of co-registration of PET with MR imaging is exemplified in regard to pediatric epilepsy. The current use of PET/CT in the evaluation of head and neck lymphoma and pediatric brain tumors is also reviewed. Emerging technologies including PET/MRI and neuroreceptor imaging are discussed. (orig.)

  20. PET imaging in pediatric neuroradiology: current and future applications

    International Nuclear Information System (INIS)

    Kim, Sunhee; Salamon, Noriko; Jackson, Hollie A.; Blueml, Stefan; Panigrahy, Ashok

    2010-01-01

    Molecular imaging with positron emitting tomography (PET) is widely accepted as an essential part of the diagnosis and evaluation of neoplastic and non-neoplastic disease processes. PET has expanded its role from the research domain into clinical application for oncology, cardiology and neuropsychiatry. More recently, PET is being used as a clinical molecular imaging tool in pediatric neuroimaging. PET is considered an accurate and noninvasive method to study brain activity and to understand pediatric neurological disease processes. In this review, specific examples of the clinical use of PET are given with respect to pediatric neuroimaging. The current use of co-registration of PET with MR imaging is exemplified in regard to pediatric epilepsy. The current use of PET/CT in the evaluation of head and neck lymphoma and pediatric brain tumors is also reviewed. Emerging technologies including PET/MRI and neuroreceptor imaging are discussed. (orig.)

  1. Atlas of PET/MR imaging in oncology

    International Nuclear Information System (INIS)

    Ratib, Osman; Schwaiger, Markus; Beyer, Thomas

    2013-01-01

    Numerous illustrated clinical cases in different oncology domains. Includes digital interactive software matching the cases in the book. Interactive version based on the latest web standard, HTML5, ensuring the widest compatibility. Edited by three international opinion leaders/imaging experts in the field. This new project on PET/MR imaging in oncology includes digital interactive software matching the cases in the book. The interactive version of the atlas is based on the latest web standard, HTML5, ensuring compatibility with any computer operating system as well as a dedicated version for Apple iPad and iPhone. The book opens with an introduction to the principles of hybrid imaging that pays particular attention to PET/MR imaging and standard PET/MR acquisition protocols. A wide range of illustrated clinical case reports are then presented. Each case study includes a short clinical history, findings, and teaching points, followed by illustrations, legends, and comments. The multimedia version of the book includes dynamic movies that allow the reader to browse through series of rotating 3D images (MIP or volume rendered), display blending between PET and MR, and dynamic visualization of 3D image volumes. The movies can be played either continuously or sequentially for better exploration of sets of images. The editors of this state-of-the-art publication are key opinion leaders in the field of multimodality imaging. Professor Osman Ratib (Geneva) and Professor Markus Schwaiger (Munich) were the first in Europe to initiate the clinical adoption of PET/MR imaging. Professor Thomas Beyer (Zurich) is an internationally renowned pioneering physicist in the field of hybrid imaging. Individual clinical cases presented in this book are co-authored by leading international radiologists and nuclear physicians experts in the use of PET and MRI.

  2. Atlas of PET/MR imaging in oncology

    Energy Technology Data Exchange (ETDEWEB)

    Ratib, Osman [University Hospital of Geneva (Switzerland). Nuclear Medicine Division; Schwaiger, Markus [Technische Univ. Muenchen (Germany). Nuklearmedizinische Klinik und Poliklinik; Beyer, Thomas (eds.) [General Hospital Vienna (Austria). Center for Medical Physics and Biomedical Engineering

    2013-08-01

    Numerous illustrated clinical cases in different oncology domains. Includes digital interactive software matching the cases in the book. Interactive version based on the latest web standard, HTML5, ensuring the widest compatibility. Edited by three international opinion leaders/imaging experts in the field. This new project on PET/MR imaging in oncology includes digital interactive software matching the cases in the book. The interactive version of the atlas is based on the latest web standard, HTML5, ensuring compatibility with any computer operating system as well as a dedicated version for Apple iPad and iPhone. The book opens with an introduction to the principles of hybrid imaging that pays particular attention to PET/MR imaging and standard PET/MR acquisition protocols. A wide range of illustrated clinical case reports are then presented. Each case study includes a short clinical history, findings, and teaching points, followed by illustrations, legends, and comments. The multimedia version of the book includes dynamic movies that allow the reader to browse through series of rotating 3D images (MIP or volume rendered), display blending between PET and MR, and dynamic visualization of 3D image volumes. The movies can be played either continuously or sequentially for better exploration of sets of images. The editors of this state-of-the-art publication are key opinion leaders in the field of multimodality imaging. Professor Osman Ratib (Geneva) and Professor Markus Schwaiger (Munich) were the first in Europe to initiate the clinical adoption of PET/MR imaging. Professor Thomas Beyer (Zurich) is an internationally renowned pioneering physicist in the field of hybrid imaging. Individual clinical cases presented in this book are co-authored by leading international radiologists and nuclear physicians experts in the use of PET and MRI.

  3. Ultrasound and PET-CT image fusion for prostate brachytherapy image guidance

    International Nuclear Information System (INIS)

    Hasford, F.

    2015-01-01

    Fusion of medical images between different cross-sectional modalities is widely used, mostly where functional images are fused with anatomical data. Ultrasound has for some time now been the standard imaging technique used for treatment planning of prostate cancer cases. While this approach is laudable and has yielded some positive results, latest developments have been the integration of images from ultrasound and other modalities such as PET-CT to compliment missing properties of ultrasound images. This study has sought to enhance diagnosis and treatment of prostate cancers by developing MATLAB algorithms to fuse ultrasound and PET-CT images. The fused ultrasound-PET-CT image has shown to contain improved quality of information than the individual input images. The fused image has the property of reduced uncertainty, increased reliability, robust system performance, and compact representation of information. The objective of co-registering the ultrasound and PET-CT images was achieved by conducting performance evaluation of the ultrasound and PET-CT imaging systems, developing image contrast enhancement algorithm, developing MATLAB image fusion algorithm, and assessing accuracy of the fusion algorithm. Performance evaluation of the ultrasound brachytherapy system produced satisfactory results in accordance with set tolerances as recommended by AAPM TG 128. Using an ultrasound brachytherapy quality assurance phantom, average axial distance measurement of 10.11 ± 0.11 mm was estimated. Average lateral distance measurements of 10.08 ± 0.07 mm, 20.01 ± 0.06 mm, 29.89 ± 0.03 mm and 39.84 ± 0.37 mm were estimated for the inter-target distances corresponding to 10 mm, 20 mm, 30 mm and 40 mm respectively. Volume accuracy assessment produced measurements of 3.97 cm 3 , 8.86 cm 3 and 20.11 cm 3 for known standard volumes of 4 cm 3 , 9 cm 3 and 20 cm 3 respectively. Depth of penetration assessment of the ultrasound system produced an estimate of 5.37 ± 0.02 cm

  4. PET/CT Atlas on Quality Control and Image Artefacts

    International Nuclear Information System (INIS)

    2014-01-01

    Combined positron emission tomography (PET)/computed tomography (CT) imaging has become a routine procedure in diagnostic radiology and nuclear medicine. The clinical review of both PET and PET/CT images requires a thorough understanding of the basics of image formation as well as an appreciation of variations of inter-patient and intra-patient image appearance. Such variations may be caused by variations in tracer accumulation and metabolism, and, perhaps more importantly, by image artefacts related to methodological pitfalls of the two modalities. This atlas on quality control (QC) and PET/CT artefacts provides guidance on typical image distortions in clinical PET/CT usage scenarios. A number of cases are presented to provide nuclear medicine and radiology professionals with an assortment of examples of possible image distortions and errors in order to support the correct interpretation of images. About 70 typical PET and PET/CT cases, comprised of image sets and cases, have been collected in this book, and all have been catalogued and have explanations as to the causes of and solutions to each individual image problem. This atlas is intended to be used as a guide on how to take proper QC measures, on performing situation and problem analysis, and on problem prevention. This book will be especially useful to medical physicists, physicians, technologists and service engineers in the clinical field

  5. The effect, identification and correction of misalignment between PET transmission and emission scans on brain PET imaging

    International Nuclear Information System (INIS)

    Zhang Xiangsong; He Zuoxiang; Tang Anwu; Qiao Suixian

    2004-01-01

    Objectives: To study the effect of misalignment between PET transmission and emission scans of brain on brain PET imaging, and the Methods to identify and correct it. Methods: 18F-FDG PET imaging was performed on 8 volunteers. The emission images were reconstructed with attenuation correction after some translations and rotations in the x-axis and transverse plane were given, 1 mm and 1 degree each step, respectively. The 3-D volume fusion of PET emission and transmission scans was used to identify the suspected misalignment on 10 18F-FDG PET brain imaging. Three Methods were used to correct the misalignment. First, to quantitate the amount of the misalignment by 3-D volume registration of PET emission and transmission scans, the emission images were reconstructed with corrected translations and rotations in x-direction and transverse plane. Second, the emission images were reconstructed with mathematic calculation of brain attenuation. Third, 18F-FDG PET brain imaging was redone with careful application of laser alignment. Results: The translations greater than 3 mm in x-direction and the rotations greater than 8 degrees in transverse plane could lead to visible artifacts, which were presented with decreasing radioactivity uptake in the cortex of half cerebrum and in the frontal cortex at the side in the translating or rotating direction, respectively. The 3-D volume fusion of PET emission and transmission scans could identify and quantitate the amount of misalignment between PET emission and transmission scans of brain. The PET emission images reconstructed with corrected misalignment and mathematic calculation of brain attenuation were consistent with redone PET brain imaging. Conclusions: The misalignment between PET transmission and emission scans of brain can lead to visible artifacts. The 3-D volume fusion of PET emission and transmission scans can identify and quantitate the amount of the misalignment. The visible artifacts caused by the misalignment can be

  6. Imaging in cardiac mass lesions

    International Nuclear Information System (INIS)

    Mundinger, A.; Gruber, H.P.; Dinkel, E.; Geibel, A.; Beck, A.; Wimmer, B.; Schlosser, V.

    1992-01-01

    In 26 patients with cardiac mass lesions confirmed by surgery, diagnostic imaging was performed preoperatively by means of two-dimensional echocardiography (26 patients), angiography (12 patients), correlative computed tomography (CT, 8 patients), and magnetic resonance imaging (MRI, 3 patients). Two-dimensional echocardiography correctly identified the cardiac masses in all patients. Angiography missed two of 12 cardiac masses; CT missed one of eight. MRI identified three of three cardiac masses. Although the sensitivity of two-dimensional echocardiography was high (100%), all methods lacked specificity. None of the methods allowed differentiation between myxoma (n=13) and thrombus (n=7). Malignancy of the lesions was successfully predicted by noninvasive imaging methods in all six patients. However, CT and MRI provided additional information concerning cardiac mural infiltration, pericardial involvement, and extracardiac tumor extension, and should be integrated within a preoperative imaging strategy. Thus two-dimensional echocardiography is the method of choice for primary assessment of patients with suspected cardiac masses. Further preoperative imaging by CT or MRI can be limited to patients with malignancies suspected on the grounds of pericardial effusion or other clinical results. (author)

  7. [¹⁸F]-fluorodeoxyglucose PET imaging of atherosclerosis

    DEFF Research Database (Denmark)

    Blomberg, Björn Alexander; Høilund-Carlsen, Poul Flemming

    2015-01-01

    [(18)F]-fluorodeoxyglucose PET ((18)FDG PET) imaging has emerged as a promising tool for assessment of atherosclerosis. By targeting atherosclerotic plaque glycolysis, a marker for plaque inflammation and hypoxia, (18)FDG PET can assess plaque vulnerability and potentially predict risk...... of atherosclerosis-related disease, such as stroke and myocardial infarction. With excellent reproducibility, (18)FDG PET can be a surrogate end point in clinical drug trials, improving trial efficiency. This article summarizes key findings in the literature, discusses limitations of (18)FDG PET imaging...

  8. Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner.

    Science.gov (United States)

    Catana, Ciprian; Wu, Yibao; Judenhofer, Martin S; Qi, Jinyi; Pichler, Bernd J; Cherry, Simon R

    2006-12-01

    PET and MRI are powerful imaging techniques that are largely complementary in the information they provide. We have designed and built a MR-compatible PET scanner based on avalanche photodiode technology that allows simultaneous acquisition of PET and MR images in small animals. The PET scanner insert uses magnetic field-insensitive, position-sensitive avalanche photodiode (PSAPD) detectors coupled, via short lengths of optical fibers, to arrays of lutetium oxyorthosilicate (LSO) scintillator crystals. The optical fibers are used to minimize electromagnetic interference between the radiofrequency and gradient coils and the PET detector system. The PET detector module components and the complete PET insert assembly are described. PET data were acquired with and without MR sequences running, and detector flood histograms were compared with the ones generated from the data acquired outside the magnet. A uniform MR phantom was also imaged to assess the effect of the PET detector on the MR data acquisition. Simultaneous PET and MRI studies of a mouse were performed ex vivo. PSAPDs can be successfully used to read out large numbers of scintillator crystals coupled through optical fibers with acceptable performance in terms of energy and timing resolution and crystal identification. The PSAPD-LSO detector performs well in the 7-T magnet, and no visible artifacts are detected in the MR images using standard pulse sequences. The first images from the complete system have been successfully acquired and reconstructed, demonstrating that simultaneous PET and MRI studies are feasible and opening up interesting possibilities for dual-modality molecular imaging studies.

  9. Cardiac imaging. A multimodality approach

    International Nuclear Information System (INIS)

    Thelen, Manfred; Erbel, Raimund; Kreitner, Karl-Friedrich; Barkhausen, Joerg

    2009-01-01

    An excellent atlas on modern diagnostic imaging of the heart Written by an interdisciplinary team of experts, Cardiac Imaging: A Multimodality Approach features an in-depth introduction to all current imaging modalities for the diagnostic assessment of the heart as well as a clinical overview of cardiac diseases and main indications for cardiac imaging. With a particular emphasis on CT and MRI, the first part of the atlas also covers conventional radiography, echocardiography, angiography and nuclear medicine imaging. Leading specialists demonstrate the latest advances in the field, and compare the strengths and weaknesses of each modality. The book's second part features clinical chapters on heart defects, endocarditis, coronary heart disease, cardiomyopathies, myocarditis, cardiac tumors, pericardial diseases, pulmonary vascular diseases, and diseases of the thoracic aorta. The authors address anatomy, pathophysiology, and clinical features, and evaluate the various diagnostic options. Key features: - Highly regarded experts in cardiology and radiology off er image-based teaching of the latest techniques - Readers learn how to decide which modality to use for which indication - Visually highlighted tables and essential points allow for easy navigation through the text - More than 600 outstanding images show up-to-date technology and current imaging protocols Cardiac Imaging: A Multimodality Approach is a must-have desk reference for cardiologists and radiologists in practice, as well as a study guide for residents in both fields. It will also appeal to cardiac surgeons, general practitioners, and medical physicists with a special interest in imaging of the heart. (orig.)

  10. Development of a PET/Cerenkov-light hybrid imaging system

    International Nuclear Information System (INIS)

    Yamamoto, Seiichi; Hamamura, Fuka; Kato, Katsuhiko; Ogata, Yoshimune; Watabe, Tadashi; Ikeda, Hayato; Kanai, Yasukazu; Hatazawa, Jun; Watabe, Hiroshi

    2014-01-01

    Purpose: Cerenkov-light imaging is a new molecular imaging technology that detects visible photons from high-speed electrons using a high sensitivity optical camera. However, the merit of Cerenkov-light imaging remains unclear. If a PET/Cerenkov-light hybrid imaging system were developed, the merit of Cerenkov-light imaging would be clarified by directly comparing these two imaging modalities. Methods: The authors developed and tested a PET/Cerenkov-light hybrid imaging system that consists of a dual-head PET system, a reflection mirror located above the subject, and a high sensitivity charge coupled device (CCD) camera. The authors installed these systems inside a black box for imaging the Cerenkov-light. The dual-head PET system employed a 1.2 × 1.2 × 10 mm 3 GSO arranged in a 33 × 33 matrix that was optically coupled to a position sensitive photomultiplier tube to form a GSO block detector. The authors arranged two GSO block detectors 10 cm apart and positioned the subject between them. The Cerenkov-light above the subject is reflected by the mirror and changes its direction to the side of the PET system and is imaged by the high sensitivity CCD camera. Results: The dual-head PET system had a spatial resolution of ∼1.2 mm FWHM and sensitivity of ∼0.31% at the center of the FOV. The Cerenkov-light imaging system's spatial resolution was ∼275μm for a 22 Na point source. Using the combined PET/Cerenkov-light hybrid imaging system, the authors successfully obtained fused images from simultaneously acquired images. The image distributions are sometimes different due to the light transmission and absorption in the body of the subject in the Cerenkov-light images. In simultaneous imaging of rat, the authors found that 18 F-FDG accumulation was observed mainly in the Harderian gland on the PET image, while the distribution of Cerenkov-light was observed in the eyes. Conclusions: The authors conclude that their developed PET/Cerenkov-light hybrid imaging

  11. Development of compact DOI-measurable PET detectors for simultaneous PET/MR Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Shao, Yiping; Sun, Xishan [University of Texas MD Anderson Cancer Center (United States); Lou, Kai [Rice University (United States)

    2015-05-18

    It is critically needed yet challenging to develop compact PET detectors with high sensitivity and uniform, high imaging resolution for improving the performance of simultaneous PET/MR imaging, particularly for an integrated/inserted small-bore system. Using the latest “edge-less” SiPM arrays for DOI measurement using the design of dual-ended-scintillator readout, we developed several compact PET detectors suited for PET/MR imaging. Each detector consists of one LYSO array with each end coupled to a SiPM array. Multiple detectors can be seamlessly tiled together along all sides to form a large detector panel. Detectors with 1.5x1.5 and 2.0x2.0 mm crystals at 20 or 30 mm lengths were studied. Readout of individual SiPM or capacitor-based signal multiplexing was used to transfer 3D interaction position-coded analog signals through flexible-print-circuit cables to dedicated ASIC frontend electronics to output digital timing pulses that encode interaction information. These digital pulses can be transferred to, through standard LVDS cables, and decoded by a FPGA-based data acquisition positioned outside the MRI scanner for coincidence event selection. Initial detector performance measurement shows excellent crystal identification even with 30 mm long crystals, ~18% and 2.8 ns energy and timing resolutions, and around 2-3 mm DOI resolution. A large size detector panel can be scaled up with these modular detectors and different PET systems can be flexibly configured with the scalable readout electronics and data acquisition, providing an important design advantage for different system and application requirements. It is expected that standard shielding of detectors, electronics and signal transfer lines can be applied for simultaneous PET/MR imaging applications, with desired DOI measurement capability to enhance the PET performance and image quality.

  12. Development of compact DOI-measurable PET detectors for simultaneous PET/MR Imaging

    International Nuclear Information System (INIS)

    Shao, Yiping; Sun, Xishan; Lou, Kai

    2015-01-01

    It is critically needed yet challenging to develop compact PET detectors with high sensitivity and uniform, high imaging resolution for improving the performance of simultaneous PET/MR imaging, particularly for an integrated/inserted small-bore system. Using the latest “edge-less” SiPM arrays for DOI measurement using the design of dual-ended-scintillator readout, we developed several compact PET detectors suited for PET/MR imaging. Each detector consists of one LYSO array with each end coupled to a SiPM array. Multiple detectors can be seamlessly tiled together along all sides to form a large detector panel. Detectors with 1.5x1.5 and 2.0x2.0 mm crystals at 20 or 30 mm lengths were studied. Readout of individual SiPM or capacitor-based signal multiplexing was used to transfer 3D interaction position-coded analog signals through flexible-print-circuit cables to dedicated ASIC frontend electronics to output digital timing pulses that encode interaction information. These digital pulses can be transferred to, through standard LVDS cables, and decoded by a FPGA-based data acquisition positioned outside the MRI scanner for coincidence event selection. Initial detector performance measurement shows excellent crystal identification even with 30 mm long crystals, ~18% and 2.8 ns energy and timing resolutions, and around 2-3 mm DOI resolution. A large size detector panel can be scaled up with these modular detectors and different PET systems can be flexibly configured with the scalable readout electronics and data acquisition, providing an important design advantage for different system and application requirements. It is expected that standard shielding of detectors, electronics and signal transfer lines can be applied for simultaneous PET/MR imaging applications, with desired DOI measurement capability to enhance the PET performance and image quality.

  13. PET/MRI for Oncologic Brain Imaging

    DEFF Research Database (Denmark)

    Rausch, Ivo; Rischka, Lucas; Ladefoged, Claes N

    2017-01-01

    The aim of this study was to compare attenuation-correction (AC) approaches for PET/MRI in clinical neurooncology.Methods:Forty-nine PET/MRI brain scans were included: brain tumor studies using18F-fluoro-ethyl-tyrosine (18F-FET) (n= 31) and68Ga-DOTANOC (n= 7) and studies of healthy subjects using18...... by Siemens Healthcare). As a reference, AC maps were derived from patient-specific CT images (CTref). PET data were reconstructed using standard settings after AC with all 4 AC methods. We report changes in diagnosis for all brain tumor patients and the following relative differences values (RDs...... of the whole brain and 10 anatomic regions segmented on MR images.Results:For brain tumor imaging (A and B), the standard PET-based diagnosis was not affected by any of the 3 MR-AC methods. For A, the average RDs of SUVmeanwere -10%, -4%, and -3% and of the VOIs 1%, 2%, and 7% for DIXON, UTE, and BD...

  14. Development of PET in Latin America. Experience of the first PET-Cyclotron Center

    International Nuclear Information System (INIS)

    Tutor, C.A.; Frias, L.

    2002-01-01

    Aim: Describe the experience of the first PET-Cyclotron Center in Latin America. Demonstrate the viability of running a PET Center in Argentina despite the economic crisis. Materials and Methods: For this study, we used a UGM/GE Quest 250 PET scan, a RDS 112 cyclotron and a Radiosynthesis Laboratory installed at the (FUESMEN) Nuclear Medicine School Foundation, located in Mendoza City, in the middle-west of Argentina. From January 1999 to March 2002, 741 studies were obtained, 731 were 18 FluorDeoxyGlucose-PET studies and 10 phantoms for calibration purposes. We used acquisition and imaging processing standard protocols, as well as research protocols designed according to the pathology under investigation. To better correlate anatomical and functional images, we used fusion techniques with (CT) Computed Tomography in some (WB) whole-body PET scans. Results: A total of 731 patients were retrospectively analyzed and classified according to statistics variables such as: 1-sex: 317 women and 414 men, 2-type of scan: 439 WB cases, 267 brain studies and 25 cardiac. From this data we divided them as PET indications and resulted in 17 cases as healthy volunteers, 422 oncological cases, 267 neurological studies and 25 cardiac for myocardial viability. According to the origin they were classified as patients coming from Mendoza 544, Buenos Aires 112, other argentine provinces 60 and foreign (Chile, Brazil and Uruguay) 15 cases. In terms of billing, 181 studies were done free of charge, 95 under research protocols were also done free of charge and 451 were charged. Conclusion: Not only the economical and political factors play an important role limiting the advances of PET Imaging in Latin America, but also the lack of a neighboring cyclotron that circumscribe many hospitals to have access to the radiopharmaceutical agent. FUESMEN was established in 1991 by three governmental entities: the (CONEA) National Commission of Atomic Energy, the (UNC) National University of Cuyo and

  15. Clinical Evaluation of PET Image Quality as a Function of Acquisition Time in a New TOF-PET/MRI Compared to TOF-PET/CT--Initial Results.

    Science.gov (United States)

    Zeimpekis, Konstantinos G; Barbosa, Felipe; Hüllner, Martin; ter Voert, Edwin; Davison, Helen; Veit-Haibach, Patrick; Delso, Gaspar

    2015-10-01

    The purpose of this study was to compare only the performance of the PET component between a TOF-PET/CT (henceforth noted as PET/CT) scanner and an integrated TOF-PET/MRI (henceforth noted as PET/MRI) scanner concerning image quality parameters and quantification in terms of standardized uptake value (SUV) as a function of acquisition time (a surrogate of dose). The CT and MR image quality were not assessed, and that is beyond the scope of this study. Five brain and five whole-body patients were included in the study. The PET/CT scan was used as a reference and the PET/MRI acquisition time was consecutively adjusted, taking into account the decay between the scans in order to expose both systems to the same amount of the emitted signal. The acquisition times were then retrospectively reduced to assess the performance of the PET/MRI for lower count rates. Image quality, image sharpness, artifacts, and noise were evaluated. SUV measurements were taken in the liver and in the white matter to compare quantification. Quantitative evaluation showed strong correlation between PET/CT and PET/MRI brain SUVs. Liver correlation was good, however, with lower uptake estimation in PET/MRI, partially justified by bio-redistribution. The clinical evaluation showed that PET/MRI offers higher image quality and sharpness with lower levels of noise and artifacts compared to PET/CT with reduced acquisition times for whole-body scans while for brain scans there is no significant difference. The TOF-PET/MRI showed higher image quality compared to TOF-PET/CT as tested with reduced imaging times. However, this result accounts mainly for body imaging, while no significant differences were found in brain imaging.

  16. Cardiac imaging. A multimodality approach

    Energy Technology Data Exchange (ETDEWEB)

    Thelen, Manfred [Johannes Gutenberg University Hospital, Mainz (Germany); Erbel, Raimund [University Hospital Essen (Germany). Dept. of Cardiology; Kreitner, Karl-Friedrich [Johannes Gutenberg University Hospital, Mainz (Germany). Clinic and Polyclinic for Diagnostic and Interventional Radiology; Barkhausen, Joerg (eds.) [University Hospital Schleswig-Holstein, Luebeck (Germany). Dept. of Radiology and Nuclear Medicine

    2009-07-01

    An excellent atlas on modern diagnostic imaging of the heart Written by an interdisciplinary team of experts, Cardiac Imaging: A Multimodality Approach features an in-depth introduction to all current imaging modalities for the diagnostic assessment of the heart as well as a clinical overview of cardiac diseases and main indications for cardiac imaging. With a particular emphasis on CT and MRI, the first part of the atlas also covers conventional radiography, echocardiography, angiography and nuclear medicine imaging. Leading specialists demonstrate the latest advances in the field, and compare the strengths and weaknesses of each modality. The book's second part features clinical chapters on heart defects, endocarditis, coronary heart disease, cardiomyopathies, myocarditis, cardiac tumors, pericardial diseases, pulmonary vascular diseases, and diseases of the thoracic aorta. The authors address anatomy, pathophysiology, and clinical features, and evaluate the various diagnostic options. Key features: - Highly regarded experts in cardiology and radiology off er image-based teaching of the latest techniques - Readers learn how to decide which modality to use for which indication - Visually highlighted tables and essential points allow for easy navigation through the text - More than 600 outstanding images show up-to-date technology and current imaging protocols Cardiac Imaging: A Multimodality Approach is a must-have desk reference for cardiologists and radiologists in practice, as well as a study guide for residents in both fields. It will also appeal to cardiac surgeons, general practitioners, and medical physicists with a special interest in imaging of the heart. (orig.)

  17. Reproducibility of Quantitative Brain Imaging Using a PET-Only and a Combined PET/MR System

    Directory of Open Access Journals (Sweden)

    Martin L. Lassen

    2017-07-01

    Full Text Available The purpose of this study was to test the feasibility of migrating a quantitative brain imaging protocol from a positron emission tomography (PET-only system to an integrated PET/MR system. Potential differences in both absolute radiotracer concentration as well as in the derived kinetic parameters as a function of PET system choice have been investigated. Five healthy volunteers underwent dynamic (R-[11C]verapamil imaging on the same day using a GE-Advance (PET-only and a Siemens Biograph mMR system (PET/MR. PET-emission data were reconstructed using a transmission-based attenuation correction (AC map (PET-only, whereas a standard MR-DIXON as well as a low-dose CT AC map was applied to PET/MR emission data. Kinetic modeling based on arterial blood sampling was performed using a 1-tissue-2-rate constant compartment model, yielding kinetic parameters (K1 and k2 and distribution volume (VT. Differences for parametric values obtained in the PET-only and the PET/MR systems were analyzed using a 2-way Analysis of Variance (ANOVA. Comparison of DIXON-based AC (PET/MR with emission data derived from the PET-only system revealed average inter-system differences of −33 ± 14% (p < 0.05 for the K1 parameter and −19 ± 9% (p < 0.05 for k2. Using a CT-based AC for PET/MR resulted in slightly lower systematic differences of −16 ± 18% for K1 and −9 ± 10% for k2. The average differences in VT were −18 ± 10% (p < 0.05 for DIXON- and −8 ± 13% for CT-based AC. Significant systematic differences were observed for kinetic parameters derived from emission data obtained from PET/MR and PET-only imaging due to different standard AC methods employed. Therefore, a transfer of imaging protocols from PET-only to PET/MR systems is not straightforward without application of proper correction methods.Clinical Trial Registration:www.clinicaltrialsregister.eu, identifier 2013-001724-19

  18. Test-retest repeatability of myocardial blood flow and infarct size using 11C-acetate micro-PET imaging in mice

    International Nuclear Information System (INIS)

    Croteau, Etienne; Renaud, Jennifer M.; McDonald, Matthew; Klein, Ran; DaSilva, Jean N.; Beanlands, Rob S.B.; DeKemp, Robert A.

    2015-01-01

    Global and regional responses of absolute myocardial blood flow index (iMBF) are used as surrogate markers to assess response to therapies in coronary artery disease. In this study, we assessed the test-retest repeatability of iMBF imaging, and the accuracy of infarct sizing in mice using 11 C-acetate PET. 11 C-Acetate cardiac PET images were acquired in healthy controls, endothelial nitric oxide synthase (eNOS) knockout transgenic mice, and mice after myocardial infarction (MI) to estimate global and regional iMBF, and myocardial infarct size compared to 18 F-FDG PET and ex-vivo histology results. Global test-retest iMBF values had good coefficients of repeatability (CR) in healthy mice, eNOS knockout mice and normally perfused regions in MI mice (CR = 1.6, 2.0 and 1.5 mL/min/g, respectively). Infarct size measured on 11 C-acetate iMBF images was also repeatable (CR = 17 %) and showed a good correlation with the infarct sizes found on 18 F-FDG PET and histopathology (r 2 > 0.77; p < 0.05). 11 C-Acetate micro-PET assessment of iMBF and infarct size is repeatable and suitable for serial investigation of coronary artery disease progression and therapy. (orig.)

  19. Importance of PET/CT for imaging of colorectal cancer

    International Nuclear Information System (INIS)

    Meinel, F.G.; Schramm, N.; Graser, A.; Reiser, M.F.; Rist, C.; Haug, A.R.

    2012-01-01

    Fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) has emerged as a very useful imaging modality in the management of colorectal carcinoma. Data from the literature regarding the role of PET/CT in the initial diagnosis, staging, radiotherapy planning, response monitoring and surveillance of colorectal carcinoma is presented. Future directions and economic aspects are discussed. Computed tomography (CT), magnetic resonance imaging (MRI) and FDG-PET for colorectal cancer and endorectal ultrasound for rectal cancer. Combined FDG-PET/CT. While other imaging modalities allow superior visualization of the extent and invasion depth of the primary tumor, PET/CT is most sensitive for the detection of distant metastases of colorectal cancer. We recommend a targeted use of PET/CT in cases of unclear M staging, prior to metastasectomy and in suspected cases of residual or recurrent colorectal carcinoma with equivocal conventional imaging. The role of PET/CT in radiotherapy planning and response monitoring needs to be determined. Currently there is no evidence to support the routine use of PET/CT for colorectal screening, staging or surveillance. To optimally exploit the synergy between morphologic and functional information, FDG-PET should generally be performed as an integrated FDG-PET/CT with a contrast-enhanced CT component in colorectal carcinoma. (orig.) [de

  20. Thoracic staging in lung cancer: prospective comparison of 18F-FDG PET/MR imaging and 18F-FDG PET/CT.

    Science.gov (United States)

    Heusch, Philipp; Buchbender, Christian; Köhler, Jens; Nensa, Felix; Gauler, Thomas; Gomez, Benedikt; Reis, Henning; Stamatis, Georgios; Kühl, Hilmar; Hartung, Verena; Heusner, Till A

    2014-03-01

    Therapeutic decisions in non-small cell lung cancer (NSCLC) patients depend on the tumor stage. PET/CT with (18)F-FDG is widely accepted as the diagnostic standard of care. The purpose of this study was to compare a dedicated pulmonary (18)F-FDG PET/MR imaging protocol with (18)F-FDG PET/CT for primary and locoregional lymph node staging in NSCLC patients using histopathology as the reference. Twenty-two patients (12 men, 10 women; mean age ± SD, 65.1 ± 9.1 y) with histopathologically confirmed NSCLC underwent (18)F-FDG PET/CT, followed by (18)F-FDG PET/MR imaging, including a dedicated pulmonary MR imaging protocol. T and N staging according to the seventh edition of the American Joint Committee on Cancer staging manual was performed by 2 readers in separate sessions for (18)F-FDG PET/CT and PET/MR imaging, respectively. Results from histopathology were used as the standard of reference. The mean and maximum standardized uptake value (SUV(mean) and SUV(max), respectively) and maximum diameter of the primary tumor was measured and compared in (18)F-FDG PET/CT and PET/MR imaging. PET/MR imaging and (18)F-FDG PET/CT agreed on T stages in 16 of 16 of patients (100%). All patients were correctly staged by (18)F-FDG PET/CT and PET/MR (100%), compared with histopathology. There was no statistically significant difference between (18)F-FDG PET/CT and (18)F-FDG PET/MR imaging for lymph node metastases detection (P = 0.48). For definition of thoracic N stages, PET/MR imaging and (18)F-FDG PET/CT were concordant in 20 of 22 patients (91%). PET/MR imaging determined the N stage correctly in 20 of 22 patients (91%). (18)F-FDG PET/CT determined the N stage correctly in 18 of 22 patients (82%). The mean differences for SUV(mean) and SUV(max) of NSCLC in (18)F-FDG PET/MR imaging and (18)F-FDG PET/CT were 0.21 and -5.06. These differences were not statistically significant (P > 0.05). The SUV(mean) and SUV(max) measurements derived from (18)F-FDG PET/CT and (18)F-FDG PET

  1. Guidelines for 18F-FDG PET and PET-CT imaging in paediatric oncology

    DEFF Research Database (Denmark)

    Stauss, J.; Franzius, C.; Pfluger, T.

    2008-01-01

    tomography ((18)F-FDG PET) in paediatric oncology. The Oncology Committee of the European Association of Nuclear Medicine (EANM) has published excellent procedure guidelines on tumour imaging with (18)F-FDG PET (Bombardieri et al., Eur J Nucl Med Mol Imaging 30:BP115-24, 2003). These guidelines, published...

  2. Role of 18F-FDG PET/CT in the diagnosis of infective endocarditis in patients with an implanted cardiac device: a prospective study

    International Nuclear Information System (INIS)

    Graziosi, Maddalena; Lorenzini, Massimiliano; Diemberger, Igor; Pasquale, Ferdinando; Ziacchi, Matteo; Biffi, Mauro; Martignani, Cristian; Boriani, Giuseppe; Rapezzi, Claudio; Nanni, Cristina; Bonfiglioli, Rachele; Fanti, Stefano; Bartoletti, Michele; Tumietto, Fabio; Viale, Pier Luigi

    2014-01-01

    Infective endocarditis (IE) is widely underdiagnosed or diagnosed after a major delay. The diagnosis is currently based on the modified DUKE criteria, where the only validated imaging technique is echocardiography, and remains challenging especially in patients with an implantable cardiac device. The aim of this study was to assess the incremental diagnostic role of 18 F-FDG PET/CT in patients with an implanted cardiac device and suspected IE. We prospectively analysed 27 consecutive patients with an implantable device evaluated for suspected device-related IE between January 2011 and June 2013. The diagnostic probability of IE was defined at presentation according to the modified DUKE criteria. PET/CT was performed as soon as possible following the clinical suspicion of IE. Patients then underwent medical or surgical treatment based on the overall clinical evaluation. During follow-up, we considered: lead cultures in patients who underwent extraction, direct inspection and lead cultures in those who underwent surgery, and a clinical/instrumental reevaluation after at least 6 months in patients who received antimicrobial treatment or had an alternative diagnosis and were not treated for IE. After the follow-up period, the diagnosis was systematically reviewed by the multidisciplinary team using the modified DUKE criteria and considering the new findings. Among the ten patients with a positive PET/CT scan, seven received a final diagnosis of ''definite IE'', one of ''possible IE'' and two of ''IE rejected''. Among the 17 patients with a negative PET/CT scan, four were false-negative and received a final diagnosis of definite IE. These patients underwent PET/CT after having started antibiotic therapy (≥48 h) or had a technically suboptimal examination. In patients with a cardiac device, PET/CT increases the diagnostic accuracy of the modified Duke criteria for IE, particularly in the subset of patients with possible IE in whom it may help the clinician manage a

  3. Monte Carlo simulations in small animal PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Branco, Susana [Universidade de Lisboa, Faculdade de Ciencias, Instituto de Biofisica e Engenharia Biomedica, Lisbon (Portugal)], E-mail: susana.silva@fc.ul.pt; Jan, Sebastien [Service Hospitalier Frederic Joliot, CEA/DSV/DRM, Orsay (France); Almeida, Pedro [Universidade de Lisboa, Faculdade de Ciencias, Instituto de Biofisica e Engenharia Biomedica, Lisbon (Portugal)

    2007-10-01

    This work is based on the use of an implemented Positron Emission Tomography (PET) simulation system dedicated for small animal PET imaging. Geant4 Application for Tomographic Emission (GATE), a Monte Carlo simulation platform based on the Geant4 libraries, is well suited for modeling the microPET FOCUS system and to implement realistic phantoms, such as the MOBY phantom, and data maps from real examinations. The use of a microPET FOCUS simulation model with GATE has been validated for spatial resolution, counting rates performances, imaging contrast recovery and quantitative analysis. Results from realistic studies of the mouse body using {sup -}F and [{sup 18}F]FDG imaging protocols are presented. These simulations include the injection of realistic doses into the animal and realistic time framing. The results have shown that it is possible to simulate small animal PET acquisitions under realistic conditions, and are expected to be useful to improve the quantitative analysis in PET mouse body studies.

  4. Motion correction options in PET/MRI.

    Science.gov (United States)

    Catana, Ciprian

    2015-05-01

    Subject motion is unavoidable in clinical and research imaging studies. Breathing is the most important source of motion in whole-body PET and MRI studies, affecting not only thoracic organs but also those in the upper and even lower abdomen. The motion related to the pumping action of the heart is obviously relevant in high-resolution cardiac studies. These two sources of motion are periodic and predictable, at least to a first approximation, which means certain techniques can be used to control the motion (eg, by acquiring the data when the organ of interest is relatively at rest). Additionally, nonperiodic and unpredictable motion can also occur during the scan. One obvious limitation of methods relying on external devices (eg, respiratory bellows or the electrocardiogram signal to monitor the respiratory or cardiac cycle, respectively) to trigger or gate the data acquisition is that the complex motion of internal organs cannot be fully characterized. However, detailed information can be obtained using either the PET or MRI data (or both) allowing the more complete characterization of the motion field so that a motion model can be built. Such a model and the information derived from simple external devices can be used to minimize the effects of motion on the collected data. In the ideal case, all the events recorded during the PET scan would be used to generate a motion-free or corrected PET image. The detailed motion field can be used for this purpose by applying it to the PET data before, during, or after the image reconstruction. Integrating all these methods for motion control, characterization, and correction into a workflow that can be used for routine clinical studies is challenging but could potentially be extremely valuable given the improvement in image quality and reduction of motion-related image artifacts. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Clinical PET/CT Atlas: A Casebook of Imaging in Oncology

    International Nuclear Information System (INIS)

    2015-01-01

    Integrated positron emission tomography/computed tomography (PET/CT) has evolved since its introduction into the commercial market more than a decade ago. It is now a key procedure, particularly in oncological imaging. Over the last years in routine clinical service, PET/CT has had a significant impact on diagnosis, treatment planning, staging, therapy, and monitoring of treatment response and has therefore played an important role in the care of cancer patients. The high sensitivity from the PET component and the specificity of the CT component give this hybrid imaging modality the unique characteristics that make PET/CT, even after over 10 years of clinical use, one of the fastest growing imaging modalities worldwide. This publication combines over 90 comprehensive cases covering all major indications of fluorodeoxyglucose (18F-FDG)-PET/CT as well as some cases of clinically relevant special tracers. The cases provide an overview of what the specific disease can look like in PET/CT, the typical pattern of the disease’s spread as well as likely pitfalls and teaching points. This PET/CT Atlas will allow professionals interested in PET/CT imaging to embrace the variety of oncological imaging by providing clinically relevant teaching files on the effectiveness and diagnostic quality of FDG-PET/CT imaging in routine applications

  6. Bayesian PET image reconstruction incorporating anato-functional joint entropy

    International Nuclear Information System (INIS)

    Tang Jing; Rahmim, Arman

    2009-01-01

    We developed a maximum a posterior (MAP) reconstruction method for positron emission tomography (PET) image reconstruction incorporating magnetic resonance (MR) image information, with the joint entropy between the PET and MR image features serving as the regularization constraint. A non-parametric method was used to estimate the joint probability density of the PET and MR images. Using realistically simulated PET and MR human brain phantoms, the quantitative performance of the proposed algorithm was investigated. Incorporation of the anatomic information via this technique, after parameter optimization, was seen to dramatically improve the noise versus bias tradeoff in every region of interest, compared to the result from using conventional MAP reconstruction. In particular, hot lesions in the FDG PET image, which had no anatomical correspondence in the MR image, also had improved contrast versus noise tradeoff. Corrections were made to figures 3, 4 and 6, and to the second paragraph of section 3.1 on 13 November 2009. The corrected electronic version is identical to the print version.

  7. Brain {sup 18}F-FDG, {sup 18}F-florbtaben PET/CT, {sup 123}I-FP-CIT SPECT and cardiac {sup 123}I-MBG imaging for diagnosis of a 'cerebral type' of Lewy Body disease

    Energy Technology Data Exchange (ETDEWEB)

    Gucht, Axel Van Der; Bélissant, Ophélie; Rabu, Corenti; Cottereau, Anne-Ségolène; Evangelista, Eva; Chalaye, Julia; Bonnot-Lours, Sophie; Fénelon, Gilles; Itti, Emmanuel [Dept. of Nuclear Medicine, AP-HP, Henri-Mondor Teaching Hospital, Crteil (France); De Langavant, Laurent Cleret [Cognitive Neurology Unit, H. Mondor Hospital, Creteil (France)

    2016-09-15

    A 67-year-old man was referred for fluctuating neuropsychiatric symptoms, featuring depression, delirious episodes, recurrent visual hallucinations and catatonic syndrome associated with cognitive decline. No parkinsonism was found clinically even under neuroleptic treatment. {sup 18}F-FDG PET/CT showed hypometabolism in the posterior associative cortex including the occipital cortex, suggesting Lewy body dementia, but {sup 123}I-FP-CIT SPECT was normal and cardiac {sup 123}I-MIBG imaging showed no signs of sympathetic denervation. Alzheimer's disease was excluded by a normal {sup 18}F-florbetaben PET/CT. This report suggests a rare case of α-synucleinopathy without brainstem involvement, referred to as 'cerebral type' of Lewy body disease.

  8. Modular strategies for PET imaging agents

    International Nuclear Information System (INIS)

    Hooker, J.M.

    2010-01-01

    In recent years, modular and simplified chemical and biological strategies have been developed for the synthesis and implementation of positron emission tomography (PET) radiotracers. New developments in bioconjugation and synthetic methodologies, in combination with advances in macromolecular delivery systems and gene-expression imaging, reflect a need to reduce radiosynthesis burden in order to accelerate imaging agent development. These new approaches, which are often mindful of existing infrastructure and available resources, are anticipated to provide a more approachable entry point for researchers interested in using PET to translate in vitro research to in vivo imaging.

  9. Modern nuclear cardiac imaging in diagnosis and clinical management of patients with left ventricular dysfunction.

    Science.gov (United States)

    Abidov, A; Hachamovitch, R; Berman, D S

    2004-12-01

    Congestive heart failure (CHF) has become a large social burden in modern Western society, with very high morbidity and mortality and extremely large financial costs. The largest cause of CHF is coronary heart disease, with ventricular dysfunction that may or may not be reversible by revascularization. Thus, evaluation of the viable myocardial tissue in patients with ischemic left ventricular (LV) dysfunction has important clinical and therapeutic implications. Furthermore, since patients with ventricular dysfunction are at higher operative risk, cardiologists and cardiac surgeons are commonly faced with issues regarding the balance between the potential risk vs benefit of revascularization procedures. Cardiac nuclear imaging [myocardial perfusion SPECT (MPS) and positron emission tomography (PET)] provide objective information that augments standard clinical and angiographic assessments of patients with ventricular dysfunction with respect to diagnosis (etiology), prognosis, and potential benefit from intervention. Development of the technology and methodology of gated MPS, now the routine method for MPS, allows assessment of the extent and severity of inducible ischemia as well as hypoperfused but viable myocardium, and also provides measurements of LV ejection fraction, regional wall motion, LV volume measurements, diastolic function and LV geometry. With PET, myocardial metabolism and blood flow reserve can be added to the measurements provided by nuclear cardiology procedures. This paper provides insight into the current evidence regarding settings in which nuclear cardiac imaging procedures are helpful in assessment of patients in the setting of coronary artery disease with severe LV dysfunction. A risk-benefit approach to MPS results is proposed, with principal focus on identifying patients at risk for major cardiac events who may benefit from myocardial revascularization.

  10. Cardiac tumors: optimal cardiac MR sequences and spectrum of imaging appearances.

    LENUS (Irish Health Repository)

    O'Donnell, David H

    2012-02-01

    OBJECTIVE: This article reviews the optimal cardiac MRI sequences for and the spectrum of imaging appearances of cardiac tumors. CONCLUSION: Recent technologic advances in cardiac MRI have resulted in the rapid acquisition of images of the heart with high spatial and temporal resolution and excellent myocardial tissue characterization. Cardiac MRI provides optimal assessment of the location, functional characteristics, and soft-tissue features of cardiac tumors, allowing accurate differentiation of benign and malignant lesions.

  11. Molecular imaging of head and neck cancers. Perspectives of PET/MRI

    International Nuclear Information System (INIS)

    Stumpp, P.; Kahn, T.; Purz, S.; Sabri, O.

    2016-01-01

    The 18 F-fluorodeoxyglucose positron emission tomography-computed tomography ( 18 F-FDG-PET/CT) procedure is a cornerstone in the diagnostics of head and neck cancers. Several years ago PET-magnetic resonance imaging (PET/MRI) also became available as an alternative hybrid multimodal imaging method. Does PET/MRI have advantages over PET/CT in the diagnostics of head and neck cancers ?The diagnostic accuracy of the standard imaging methods CT, MRI and PET/CT is depicted according to currently available meta-analyses and studies concerning the use of PET/MRI for these indications are summarized. In all studies published up to now PET/MRI did not show superiority regarding the diagnostic accuracy in head and neck cancers; however, there is some evidence that in the future PET/MRI can contribute to tumor characterization and possibly be used to predict tumor response to therapy with the use of multiparametric imaging. Currently, 18 F-FDG-PET/CT is not outperformed by PET/MRI in the diagnostics of head and neck cancers. The additive value of PET/MRI due to the use of multiparametric imaging needs to be investigated in future research. (orig.) [de

  12. TH-E-202-02: The Use of Hypoxia PET Imaging for Radiotherapy

    International Nuclear Information System (INIS)

    Humm, J.

    2016-01-01

    PET/CT is a very important imaging tool in the management of oncology patients. PET/CT has been applied for treatment planning and response evaluation in radiation therapy. This educational session will discuss: Pitfalls and remedies in PET/CT imaging for RT planning The use of hypoxia PET imaging for radiotherapy PET for tumor response evaluation The first presentation will address the issue of mis-registration between the CT and PET images in the thorax and the abdomen. We will discuss the challenges of respiratory gating and introduce an average CT technique to improve the registration for dose calculation and image-guidance in radiation therapy. The second presentation will discuss the use of hypoxia PET Imaging for radiation therapy. We will discuss various hypoxia radiotracers, the choice of clinical acquisition protocol (in particular a single late static acquisition versus a dynamic acquisition), and the compartmental modeling with different transfer rate constants explained. We will demonstrate applications of hypoxia imaging for dose escalation/de-escalation in clinical trials. The last presentation will discuss the use of PET/CT for tumor response evaluation. We will discuss anatomic response assessment vs. metabolic response assessment, visual evaluation and semi-quantitative evaluation, and limitations of current PET/CT assessment. We will summarize clinical trials using PET response in guiding adaptive radiotherapy. Finally, we will summarize recent advancements in PET/CT radiomics and non-FDG PET tracers for response assessment. Learning Objectives: Identify the causes of mis-registration of CT and PET images in PET/CT, and review the strategies to remedy the issue. Understand the basics of PET imaging of tumor hypoxia (radiotracers, how PET measures the hypoxia selective uptake, imaging protocols, applications in chemo-radiation therapy). Understand the basics of dynamic PET imaging, compartmental modeling and parametric images. Understand the

  13. TH-E-202-02: The Use of Hypoxia PET Imaging for Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Humm, J. [Memorial Sloan-Kettering Cancer Center (United States)

    2016-06-15

    PET/CT is a very important imaging tool in the management of oncology patients. PET/CT has been applied for treatment planning and response evaluation in radiation therapy. This educational session will discuss: Pitfalls and remedies in PET/CT imaging for RT planning The use of hypoxia PET imaging for radiotherapy PET for tumor response evaluation The first presentation will address the issue of mis-registration between the CT and PET images in the thorax and the abdomen. We will discuss the challenges of respiratory gating and introduce an average CT technique to improve the registration for dose calculation and image-guidance in radiation therapy. The second presentation will discuss the use of hypoxia PET Imaging for radiation therapy. We will discuss various hypoxia radiotracers, the choice of clinical acquisition protocol (in particular a single late static acquisition versus a dynamic acquisition), and the compartmental modeling with different transfer rate constants explained. We will demonstrate applications of hypoxia imaging for dose escalation/de-escalation in clinical trials. The last presentation will discuss the use of PET/CT for tumor response evaluation. We will discuss anatomic response assessment vs. metabolic response assessment, visual evaluation and semi-quantitative evaluation, and limitations of current PET/CT assessment. We will summarize clinical trials using PET response in guiding adaptive radiotherapy. Finally, we will summarize recent advancements in PET/CT radiomics and non-FDG PET tracers for response assessment. Learning Objectives: Identify the causes of mis-registration of CT and PET images in PET/CT, and review the strategies to remedy the issue. Understand the basics of PET imaging of tumor hypoxia (radiotracers, how PET measures the hypoxia selective uptake, imaging protocols, applications in chemo-radiation therapy). Understand the basics of dynamic PET imaging, compartmental modeling and parametric images. Understand the

  14. A small animal PET based on GAPDs and charge signal transmission approach for hybrid PET-MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Jihoon; Choi, Yong; Hong, Key Jo; Hu, Wei; Jung, Jin Ho; Huh, Yoonsuk [Department of Electronic Engineering, Sogang University, 1 Shinsu-Dong, Mapo-Gu, Seoul 121-742 (Korea, Republic of); Kim, Byung-Tae, E-mail: ychoi.image@gmail.com [Department of Nuclear Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Ilwon-Dong, Gangnam-Gu, Seoul 135-710 (Korea, Republic of)

    2011-08-15

    Positron emission tomography (PET) employing Geiger-mode avalanche photodiodes (GAPDs) and charge signal transmission approach was developed for small animal imaging. Animal PET contained 16 LYSO and GAPD detector modules that were arranged in a 70 mm diameter ring with an axial field of view of 13 mm. The GAPDs charge output signals were transmitted to a preamplifier located remotely using 300 cm flexible flat cables. The position decoder circuits (PDCs) were used to multiplex the PET signals from 256 to 4 channels. The outputs of the PDCs were digitized and further-processed in the data acquisition unit. The cross-compatibilities of the PET detectors and MRI were assessed outside and inside the MRI. Experimental studies of the developed full ring PET were performed to examine the spatial resolution and sensitivity. Phantom and mouse images were acquired to examine the imaging performance. The mean energy and time resolution of the PET detector were 17.6% and 1.5 ns, respectively. No obvious degradation on PET and MRI was observed during simultaneous PET-MRI data acquisition. The measured spatial resolution and sensitivity at the CFOV were 2.8 mm and 0.7%, respectively. In addition, a 3 mm diameter line source was clearly resolved in the hot-sphere phantom images. The reconstructed transaxial PET images of the mouse brain and tumor displaying the glucose metabolism patterns were imaged well. These results demonstrate GAPD and the charge signal transmission approach can allow the development of high performance small animal PET with improved MR compatibility.

  15. Test-retest repeatability of myocardial blood flow and infarct size using {sup 11}C-acetate micro-PET imaging in mice

    Energy Technology Data Exchange (ETDEWEB)

    Croteau, Etienne; Renaud, Jennifer M.; McDonald, Matthew; Klein, Ran; DaSilva, Jean N.; Beanlands, Rob S.B.; DeKemp, Robert A. [University of Ottawa Heart Institute, National Cardiac PET Centre, Ottawa, Ontario (Canada)

    2015-09-15

    Global and regional responses of absolute myocardial blood flow index (iMBF) are used as surrogate markers to assess response to therapies in coronary artery disease. In this study, we assessed the test-retest repeatability of iMBF imaging, and the accuracy of infarct sizing in mice using {sup 11}C-acetate PET. {sup 11}C-Acetate cardiac PET images were acquired in healthy controls, endothelial nitric oxide synthase (eNOS) knockout transgenic mice, and mice after myocardial infarction (MI) to estimate global and regional iMBF, and myocardial infarct size compared to {sup 18}F-FDG PET and ex-vivo histology results. Global test-retest iMBF values had good coefficients of repeatability (CR) in healthy mice, eNOS knockout mice and normally perfused regions in MI mice (CR = 1.6, 2.0 and 1.5 mL/min/g, respectively). Infarct size measured on {sup 11}C-acetate iMBF images was also repeatable (CR = 17 %) and showed a good correlation with the infarct sizes found on {sup 18}F-FDG PET and histopathology (r{sup 2} > 0.77; p < 0.05). {sup 11}C-Acetate micro-PET assessment of iMBF and infarct size is repeatable and suitable for serial investigation of coronary artery disease progression and therapy. (orig.)

  16. PET/MRI in Oncological Imaging: State of the Art

    Science.gov (United States)

    Bashir, Usman; Mallia, Andrew; Stirling, James; Joemon, John; MacKewn, Jane; Charles-Edwards, Geoff; Goh, Vicky; Cook, Gary J.

    2015-01-01

    Positron emission tomography (PET) combined with magnetic resonance imaging (MRI) is a hybrid technology which has recently gained interest as a potential cancer imaging tool. Compared with CT, MRI is advantageous due to its lack of ionizing radiation, superior soft-tissue contrast resolution, and wider range of acquisition sequences. Several studies have shown PET/MRI to be equivalent to PET/CT in most oncological applications, possibly superior in certain body parts, e.g., head and neck, pelvis, and in certain situations, e.g., cancer recurrence. This review will update the readers on recent advances in PET/MRI technology and review key literature, while highlighting the strengths and weaknesses of PET/MRI in cancer imaging. PMID:26854157

  17. PET/MRI in Oncological Imaging: State of the Art

    Directory of Open Access Journals (Sweden)

    Usman Bashir

    2015-07-01

    Full Text Available Positron emission tomography (PET combined with magnetic resonance imaging (MRI is a hybrid technology which has recently gained interest as a potential cancer imaging tool. Compared with CT, MRI is advantageous due to its lack of ionizing radiation, superior soft-tissue contrast resolution, and wider range of acquisition sequences. Several studies have shown PET/MRI to be equivalent to PET/CT in most oncological applications, possibly superior in certain body parts, e.g., head and neck, pelvis, and in certain situations, e.g., cancer recurrence. This review will update the readers on recent advances in PET/MRI technology and review key literature, while highlighting the strengths and weaknesses of PET/MRI in cancer imaging.

  18. ASCI 2010 contrast media guideline for cardiac imaging: a report of the Asian Society of Cardiovascular Imaging cardiac computed tomography and cardiac magnetic resonance imaging guideline working group

    Science.gov (United States)

    Kitagawa, Kakuya; Tsai, I-Chen; Chan, Carmen; Yu, Wei; Yong, Hwan Seok; Choi, Byoung Wook

    2010-01-01

    The use of contrast media for cardiac imaging becomes increasing as the widespread of cardiac CT and cardiac MR. A radiologist needs to carefully consider the indication and the injection protocol of contrast media to be used as well as the possibility of adverse effect. There are several guidelines for contrast media in western countries. However, these are focusing the adverse effect of contrast media. The Asian Society of Cardiovascular Imaging, the only society dedicated to cardiovascular imaging in Asia, formed a Working Group and created a guideline, which summarizes the integrated knowledge of contrast media for cardiac imaging. In cardiac imaging, coronary artery evaluation is feasible by non-contrast MR angiography, which can be an alternative examination in high risk patients for the use of iodine contrast media. Furthermore, the body habitus of Asian patients is usually smaller than that of their western counterparts. This necessitates modifications in the injection protocol and in the formula for calculation of estimated glomerular filtration rate. This guideline provided fundamental information for the use of contrast media for Asian patients in cardiac imaging. PMID:20931289

  19. PET and MRI: The Odd Couple or a Match Made in Heaven?

    Science.gov (United States)

    Catana, Ciprian; Guimaraes, Alexander R.; Rosen, Bruce R.

    2013-01-01

    Positron emission tomography (PET) and magnetic resonance imaging (MRI) are imaging modalities routinely used for clinical and research applications. Integrated scanners capable of acquiring PET and MRI data in the same imaging session, sequentially or simultaneously, have recently become available for human use. In this manuscript, we describe some of the technical advances that allowed the development of human PET/MR scanners, briefly discuss methodological challenges and opportunities provided by this novel technology and present potential oncologic, cardiac, and neuro-psychiatric applications. These examples range from studies that might immediately benefit from PET/MR to more advanced applications where future development might have an even broader impact. PMID:23492887

  20. Simultaneous MRI and PET imaging of a rat brain

    Energy Technology Data Exchange (ETDEWEB)

    Raylman, Raymond R [Center for Advanced Imaging, Department of Radiology, Box 9236, West Virginia University, Morgantown, WV (United States); Majewski, Stan [Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, VA (United States); Lemieux, Susan K [Center for Advanced Imaging, Department of Radiology, Box 9236, West Virginia University, Morgantown, WV (United States); Velan, S Sendhil [Center for Advanced Imaging, Department of Radiology, Box 9236, West Virginia University, Morgantown, WV (United States); Kross, Brian [Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, VA (United States); Popov, Vladimir [Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, VA (United States); Smith, Mark F [Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, VA (United States); Weisenberger, Andrew G [Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, VA (United States); Zorn, Carl [Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, VA (United States); Marano, Gary D [Center for Advanced Imaging, Department of Radiology, Box 9236, West Virginia University, Morgantown, WV (United States)

    2006-12-21

    Multi-modality imaging is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET fused with anatomical structure images created by MRI will allow the correlation of form with function. Our group is developing a system to acquire MRI and PET images contemporaneously. The prototype device consists of two opposed detector heads, operating in coincidence mode. Each MRI-PET detector module consists of an array of LSO detector elements coupled through a long fibre optic light guide to a single Hamamatsu flat panel position-sensitive photomultiplier tube (PSPMT). The use of light guides allows the PSPMTs to be positioned outside the bore of a 3T MRI scanner where the magnetic field is relatively small. To test the device, simultaneous MRI and PET images of the brain of a male Sprague Dawley rat injected with FDG were successfully obtained. The images revealed no noticeable artefacts in either image set. Future work includes the construction of a full ring PET scanner, improved light guides and construction of a specialized MRI coil to permit higher quality MRI imaging.

  1. Simultaneous MRI and PET imaging of a rat brain

    International Nuclear Information System (INIS)

    Raylman, Raymond R; Majewski, Stan; Lemieux, Susan K; Velan, S Sendhil; Kross, Brian; Popov, Vladimir; Smith, Mark F; Weisenberger, Andrew G; Zorn, Carl; Marano, Gary D

    2006-01-01

    Multi-modality imaging is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET fused with anatomical structure images created by MRI will allow the correlation of form with function. Our group is developing a system to acquire MRI and PET images contemporaneously. The prototype device consists of two opposed detector heads, operating in coincidence mode. Each MRI-PET detector module consists of an array of LSO detector elements coupled through a long fibre optic light guide to a single Hamamatsu flat panel position-sensitive photomultiplier tube (PSPMT). The use of light guides allows the PSPMTs to be positioned outside the bore of a 3T MRI scanner where the magnetic field is relatively small. To test the device, simultaneous MRI and PET images of the brain of a male Sprague Dawley rat injected with FDG were successfully obtained. The images revealed no noticeable artefacts in either image set. Future work includes the construction of a full ring PET scanner, improved light guides and construction of a specialized MRI coil to permit higher quality MRI imaging

  2. In vivo PET imaging of neuroinflammation in Alzheimer's disease.

    Science.gov (United States)

    Lagarde, Julien; Sarazin, Marie; Bottlaender, Michel

    2018-05-01

    Increasing evidence suggests that neuroinflammation contributes to the pathophysiology of many neurodegenerative diseases, especially Alzheimer's disease (AD). Molecular imaging by PET may be a useful tool to assess neuroinflammation in vivo, thus helping to decipher the complex role of inflammatory processes in the pathophysiology of neurodegenerative diseases and providing a potential means of monitoring the effect of new therapeutic approaches. For this objective, the main target of PET studies is the 18 kDa translocator protein (TSPO), as it is overexpressed by activated microglia. In the present review, we describe the most widely used PET tracers targeting the TSPO, the methodological issues in tracer quantification and summarize the results obtained by TSPO PET imaging in AD, as well as in neurodegenerative disorders associated with AD, in psychiatric disorders and ageing. We also briefly describe alternative PET targets and imaging modalities to study neuroinflammation. Lastly, we question the meaning of PET imaging data in the context of a highly complex and multifaceted role of neuroinflammation in neurodegenerative diseases. This overview leads to the conclusion that PET imaging of neuroinflammation is a promising way of deciphering the enigma of the pathophysiology of AD and of monitoring the effect of new therapies.

  3. 4D PET iterative deconvolution with spatiotemporal regularization for quantitative dynamic PET imaging.

    Science.gov (United States)

    Reilhac, Anthonin; Charil, Arnaud; Wimberley, Catriona; Angelis, Georgios; Hamze, Hasar; Callaghan, Paul; Garcia, Marie-Paule; Boisson, Frederic; Ryder, Will; Meikle, Steven R; Gregoire, Marie-Claude

    2015-09-01

    Quantitative measurements in dynamic PET imaging are usually limited by the poor counting statistics particularly in short dynamic frames and by the low spatial resolution of the detection system, resulting in partial volume effects (PVEs). In this work, we present a fast and easy to implement method for the restoration of dynamic PET images that have suffered from both PVE and noise degradation. It is based on a weighted least squares iterative deconvolution approach of the dynamic PET image with spatial and temporal regularization. Using simulated dynamic [(11)C] Raclopride PET data with controlled biological variations in the striata between scans, we showed that the restoration method provides images which exhibit less noise and better contrast between emitting structures than the original images. In addition, the method is able to recover the true time activity curve in the striata region with an error below 3% while it was underestimated by more than 20% without correction. As a result, the method improves the accuracy and reduces the variability of the kinetic parameter estimates calculated from the corrected images. More importantly it increases the accuracy (from less than 66% to more than 95%) of measured biological variations as well as their statistical detectivity. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  4. PET tracer for imaging of neuroendocrine tumors

    DEFF Research Database (Denmark)

    2013-01-01

    There is provided a radiolabelled peptide-based compound for diagnostic imaging using positron emission tomography (PET). The compound may thus be used for diagnosis of malignant diseases. The compound is particularly useful for imaging of somatostatin overexpression in tumors, wherein the compound...... is capable of being imaged by PET when administered with a target dose in the range of 150-350 MBq, such as 150-250 MBq, preferable in the range of 191-210 MBq....

  5. Role of {sup 18}F-FDG PET/CT in the diagnosis of infective endocarditis in patients with an implanted cardiac device: a prospective study

    Energy Technology Data Exchange (ETDEWEB)

    Graziosi, Maddalena; Lorenzini, Massimiliano; Diemberger, Igor; Pasquale, Ferdinando; Ziacchi, Matteo; Biffi, Mauro; Martignani, Cristian; Boriani, Giuseppe; Rapezzi, Claudio [Alma Mater-University of Bologna, and S. Orsola-Malpighi Hospital, Cardiology Unit, Department of Experimental, Diagnostic and Specialty Medicine, Bologna (Italy); Nanni, Cristina; Bonfiglioli, Rachele; Fanti, Stefano [Alma Mater-University of Bologna, and S. Orsola-Malpighi Hospital, Nuclear Medicine Unit, Department of Experimental, Diagnostic and Specialty Medicine, Bologna (Italy); Bartoletti, Michele; Tumietto, Fabio; Viale, Pier Luigi [Alma Mater-University of Bologna, and S. Orsola-Malpighi Hospital, Infectious Diseases Unit, Department of Medical and Surgical Sciences, Bologna (Italy)

    2014-08-15

    Infective endocarditis (IE) is widely underdiagnosed or diagnosed after a major delay. The diagnosis is currently based on the modified DUKE criteria, where the only validated imaging technique is echocardiography, and remains challenging especially in patients with an implantable cardiac device. The aim of this study was to assess the incremental diagnostic role of {sup 18}F-FDG PET/CT in patients with an implanted cardiac device and suspected IE. We prospectively analysed 27 consecutive patients with an implantable device evaluated for suspected device-related IE between January 2011 and June 2013. The diagnostic probability of IE was defined at presentation according to the modified DUKE criteria. PET/CT was performed as soon as possible following the clinical suspicion of IE. Patients then underwent medical or surgical treatment based on the overall clinical evaluation. During follow-up, we considered: lead cultures in patients who underwent extraction, direct inspection and lead cultures in those who underwent surgery, and a clinical/instrumental reevaluation after at least 6 months in patients who received antimicrobial treatment or had an alternative diagnosis and were not treated for IE. After the follow-up period, the diagnosis was systematically reviewed by the multidisciplinary team using the modified DUKE criteria and considering the new findings. Among the ten patients with a positive PET/CT scan, seven received a final diagnosis of ''definite IE'', one of ''possible IE'' and two of ''IE rejected''. Among the 17 patients with a negative PET/CT scan, four were false-negative and received a final diagnosis of definite IE. These patients underwent PET/CT after having started antibiotic therapy (≥48 h) or had a technically suboptimal examination. In patients with a cardiac device, PET/CT increases the diagnostic accuracy of the modified Duke criteria for IE, particularly in the subset of

  6. Combined SPECT/CT and PET/CT for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Paolo [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Larobina, Michele [Istituto di Biostrutture e Bioimmagini, Consiglio Nazionale delle Ricerche, Via Tommaso De Amicis, 95, Naples I-80145 (Italy); Di Lillo, Francesca [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Del Vecchio, Silvana [Università di Napoli Federico II, Dipartimento di Scienze Biomediche Avanzate, Via Pansini, 5, Naples I-80131 (Italy); Mettivier, Giovanni, E-mail: mettivier@na.infn.it [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy)

    2016-02-11

    In the field of nuclear medicine imaging, breast imaging for cancer diagnosis is still mainly based on 2D imaging techniques. Three-dimensional tomographic imaging with whole-body PET or SPECT scanners, when used for imaging the breast, has performance limits in terms of spatial resolution and sensitivity, which can be overcome only with a dedicated instrumentation. However, only few hybrid imaging systems for PET/CT or SPECT/CT dedicated to the breast have been developed in the last decade, providing complementary functional and anatomical information on normal breast tissue and lesions. These systems are still under development and clinical trials on just few patients have been reported; no commercial dedicated breast PET/CT or SPECT/CT is available. This paper reviews combined dedicated breast PET/CT and SPECT/CT scanners described in the recent literature, with focus on their technological aspects.

  7. Quantitative myocardial blood flow with Rubidium-82 PET

    DEFF Research Database (Denmark)

    Hagemann, Christoffer E; Ghotbi, Adam A; Kjær, Andreas

    2015-01-01

    Positron emission tomography (PET) allows assessment of myocardial blood flow in absolute terms (ml/min/g). Quantification of myocardial blood flow (MBF) and myocardial flow reserve (MFR) extend the scope of conventional semi-quantitative myocardial perfusion imaging (MPI): e.g. in 1) identificat......Positron emission tomography (PET) allows assessment of myocardial blood flow in absolute terms (ml/min/g). Quantification of myocardial blood flow (MBF) and myocardial flow reserve (MFR) extend the scope of conventional semi-quantitative myocardial perfusion imaging (MPI): e.g. in 1...... global MFR and major adverse cardiovascular events (MACE), and together with new diagnostic possibilities from measuring the longitudinal myocardial perfusion gradient, cardiac (82)Rb PET faces a promising clinical future. This article reviews current evidence on quantitative (82)Rb PET's ability...

  8. Simultaneous maximum a posteriori longitudinal PET image reconstruction

    Science.gov (United States)

    Ellis, Sam; Reader, Andrew J.

    2017-09-01

    Positron emission tomography (PET) is frequently used to monitor functional changes that occur over extended time scales, for example in longitudinal oncology PET protocols that include routine clinical follow-up scans to assess the efficacy of a course of treatment. In these contexts PET datasets are currently reconstructed into images using single-dataset reconstruction methods. Inspired by recently proposed joint PET-MR reconstruction methods, we propose to reconstruct longitudinal datasets simultaneously by using a joint penalty term in order to exploit the high degree of similarity between longitudinal images. We achieved this by penalising voxel-wise differences between pairs of longitudinal PET images in a one-step-late maximum a posteriori (MAP) fashion, resulting in the MAP simultaneous longitudinal reconstruction (SLR) method. The proposed method reduced reconstruction errors and visually improved images relative to standard maximum likelihood expectation-maximisation (ML-EM) in simulated 2D longitudinal brain tumour scans. In reconstructions of split real 3D data with inserted simulated tumours, noise across images reconstructed with MAP-SLR was reduced to levels equivalent to doubling the number of detected counts when using ML-EM. Furthermore, quantification of tumour activities was largely preserved over a variety of longitudinal tumour changes, including changes in size and activity, with larger changes inducing larger biases relative to standard ML-EM reconstructions. Similar improvements were observed for a range of counts levels, demonstrating the robustness of the method when used with a single penalty strength. The results suggest that longitudinal regularisation is a simple but effective method of improving reconstructed PET images without using resolution degrading priors.

  9. PET-MRI: the likely future of molecular imaging

    International Nuclear Information System (INIS)

    Chen Xiang; Zhao Jinhua; Zhao Jun

    2008-01-01

    PET-CT is a successful combination of functional and morphologic information, and it has already been shown to have great value both in clinics and in scientific research. MRI is another kind of morphologic imaging method, in contrast to CT, MRI can yield images with higher soft-tissue contrast and better spatial resolution. The combination of PET and MRI for simultaneous data acquisition should have far- reaching consequences for molecular imaging. This review will talk about the problems met in the development of PET-MRI and describe the progress to date and look forward to its potential application. (authors)

  10. Imaging Alzheimer's disease pathophysiology with PET

    Directory of Open Access Journals (Sweden)

    Lucas Porcello Schilling

    Full Text Available ABSTRACT Alzheimer's disease (AD has been reconceptualised as a dynamic pathophysiological process characterized by preclinical, mild cognitive impairment (MCI, and dementia stages. Positron emission tomography (PET associated with various molecular imaging agents reveals numerous aspects of dementia pathophysiology, such as brain amyloidosis, tau accumulation, neuroreceptor changes, metabolism abnormalities and neuroinflammation in dementia patients. In the context of a growing shift toward presymptomatic early diagnosis and disease-modifying interventions, PET molecular imaging agents provide an unprecedented means of quantifying the AD pathophysiological process, monitoring disease progression, ascertaining whether therapies engage their respective brain molecular targets, as well as quantifying pharmacological responses. In the present study, we highlight the most important contributions of PET in describing brain molecular abnormalities in AD.

  11. Progress of PET imaging in Schizophrenia

    International Nuclear Information System (INIS)

    Cai Li; Gao Shuo

    2011-01-01

    PET is an important functional neuroimaging technique that can be used to assessment of cerebral metabolic activity and blood flow and identifies the distribution of important neurotransmitters in the human brain. Compared with other conventional imaging techniques, PET enables regional cerebral glucose metabolism, blood flow, dopaminergic and serotonergic receptor function to be assessed qualitatively and quantitatively. In recent years, PET increasingly being used greatly to advance our understanding of the neurobiology and pathophysiology of schizophrenia. This review focuses on the use of PET tracers in identifying regional brain abnormalities and regions associated with cognitive functioning in schizophrenia. (authors)

  12. Kinetic modeling in PET imaging of hypoxia

    DEFF Research Database (Denmark)

    Li, Fan; Jørgensen, Jesper Tranekjær; Hansen, Anders E

    2014-01-01

    be used for non-invasive mapping of tissue oxygenation in vivo and several hypoxia specific PET tracers have been developed. Evaluation of PET data in the clinic is commonly based on visual assessment together with semiquantitative measurements e.g. standard uptake value (SUV). However, dynamic PET......Tumor hypoxia is associated with increased therapeutic resistance leading to poor treatment outcome. Therefore the ability to detect and quantify intratumoral oxygenation could play an important role in future individual personalized treatment strategies. Positron Emission Tomography (PET) can...... analysis for PET imaging of hypoxia....

  13. Spatio-temporal diffusion of dynamic PET images

    International Nuclear Information System (INIS)

    Tauber, C; Chalon, S; Guilloteau, D; Stute, S; Buvat, I; Chau, M; Spiteri, P

    2011-01-01

    Positron emission tomography (PET) images are corrupted by noise. This is especially true in dynamic PET imaging where short frames are required to capture the peak of activity concentration after the radiotracer injection. High noise results in a possible bias in quantification, as the compartmental models used to estimate the kinetic parameters are sensitive to noise. This paper describes a new post-reconstruction filter to increase the signal-to-noise ratio in dynamic PET imaging. It consists in a spatio-temporal robust diffusion of the 4D image based on the time activity curve (TAC) in each voxel. It reduces the noise in homogeneous areas while preserving the distinct kinetics in regions of interest corresponding to different underlying physiological processes. Neither anatomical priors nor the kinetic model are required. We propose an automatic selection of the scale parameter involved in the diffusion process based on a robust statistical analysis of the distances between TACs. The method is evaluated using Monte Carlo simulations of brain activity distributions. We demonstrate the usefulness of the method and its superior performance over two other post-reconstruction spatial and temporal filters. Our simulations suggest that the proposed method can be used to significantly increase the signal-to-noise ratio in dynamic PET imaging.

  14. Evaluation of PET Imaging Resolution Using 350 mu{m} Pixelated CZT as a VP-PET Insert Detector

    Science.gov (United States)

    Yin, Yongzhi; Chen, Ximeng; Li, Chongzheng; Wu, Heyu; Komarov, Sergey; Guo, Qingzhen; Krawczynski, Henric; Meng, Ling-Jian; Tai, Yuan-Chuan

    2014-02-01

    A cadmium-zinc-telluride (CZT) detector with 350 μm pitch pixels was studied in high-resolution positron emission tomography (PET) imaging applications. The PET imaging system was based on coincidence detection between a CZT detector and a lutetium oxyorthosilicate (LSO)-based Inveon PET detector in virtual-pinhole PET geometry. The LSO detector is a 20 ×20 array, with 1.6 mm pitches, and 10 mm thickness. The CZT detector uses ac 20 ×20 ×5 mm substrate, with 350 μm pitch pixelated anodes and a coplanar cathode. A NEMA NU4 Na-22 point source of 250 μm in diameter was imaged by this system. Experiments show that the image resolution of single-pixel photopeak events was 590 μm FWHM while the image resolution of double-pixel photopeak events was 640 μm FWHM. The inclusion of double-pixel full-energy events increased the sensitivity of the imaging system. To validate the imaging experiment, we conducted a Monte Carlo (MC) simulation for the same PET system in Geant4 Application for Emission Tomography. We defined LSO detectors as a scanner ring and 350 μm pixelated CZT detectors as an insert ring. GATE simulated coincidence data were sorted into an insert-scanner sinogram and reconstructed. The image resolution of MC-simulated data (which did not factor in positron range and acolinearity effect) was 460 μm at FWHM for single-pixel events. The image resolutions of experimental data, MC simulated data, and theoretical calculation are all close to 500 μm FWHM when the proposed 350 μm pixelated CZT detector is used as a PET insert. The interpolation algorithm for the charge sharing events was also investigated. The PET image that was reconstructed using the interpolation algorithm shows improved image resolution compared with the image resolution without interpolation algorithm.

  15. Monte Carlo simulation of PET and SPECT imaging of {sup 90}Y

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Akihiko, E-mail: takahsr@hs.med.kyushu-u.ac.jp; Sasaki, Masayuki [Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Himuro, Kazuhiko; Yamashita, Yasuo; Komiya, Isao [Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Baba, Shingo [Department of Clinical Radiology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan)

    2015-04-15

    Purpose: Yittrium-90 ({sup 90}Y) is traditionally thought of as a pure beta emitter, and is used in targeted radionuclide therapy, with imaging performed using bremsstrahlung single-photon emission computed tomography (SPECT). However, because {sup 90}Y also emits positrons through internal pair production with a very small branching ratio, positron emission tomography (PET) imaging is also available. Because of the insufficient image quality of {sup 90}Y bremsstrahlung SPECT, PET imaging has been suggested as an alternative. In this paper, the authors present the Monte Carlo-based simulation–reconstruction framework for {sup 90}Y to comprehensively analyze the PET and SPECT imaging techniques and to quantitatively consider the disadvantages associated with them. Methods: Our PET and SPECT simulation modules were developed using Monte Carlo simulation of Electrons and Photons (MCEP), developed by Dr. S. Uehara. PET code (MCEP-PET) generates a sinogram, and reconstructs the tomography image using a time-of-flight ordered subset expectation maximization (TOF-OSEM) algorithm with attenuation compensation. To evaluate MCEP-PET, simulated results of {sup 18}F PET imaging were compared with the experimental results. The results confirmed that MCEP-PET can simulate the experimental results very well. The SPECT code (MCEP-SPECT) models the collimator and NaI detector system, and generates the projection images and projection data. To save the computational time, the authors adopt the prerecorded {sup 90}Y bremsstrahlung photon data calculated by MCEP. The projection data are also reconstructed using the OSEM algorithm. The authors simulated PET and SPECT images of a water phantom containing six hot spheres filled with different concentrations of {sup 90}Y without background activity. The amount of activity was 163 MBq, with an acquisition time of 40 min. Results: The simulated {sup 90}Y-PET image accurately simulated the experimental results. PET image is visually

  16. Development of PET Imaging to Visualize Activated Macrophages Accumulated in the Transplanted iPSc-Derived Cardiac Myocytes of Allogeneic Origin for Detecting the Immune Rejection of Allogeneic Cell Transplants in Mice.

    Directory of Open Access Journals (Sweden)

    Noriyuki Kashiyama

    Full Text Available Allogeneic transplantation (Tx of induced pluripotent stem cells (iPSCs is a promising tissue regeneration therapy. However, this inevitably induces macrophage-mediated immune response against the graft, limiting its therapeutic efficacy. Monitoring the magnitude of the immune response using imaging tools would be useful for prolonging graft survival and increasing the therapy longevity. Minimally invasive quantitative detection of activated macrophages by medical imaging technologies such as positron emission tomography (PET imaging targets translocator protein (TSPO, which is highly expressed on mitochondrial membrane, especially in activated macrophage. N,N-diethyl-2-[4-(2-fluoroethoxy phenyl]-5,7-dimethylpyrazolo[1,5-a]pyrimidine-3-acetamide (DPA-714 is known as a TSPO ligand used in clinical settings. We herein hypothesized that immune rejection of the transplanted iPSC-derived cardiomyocytes (iPSC-CMs of allogeneic origin may be quantitated using 18F-DPA-714-PET imaging study. iPSC-CM cell-sheets of C57BL/6 mice origin were transplanted on the surface of the left ventricle (LV of C57BL/6 mice as a syngeneic cell-transplant model (syngeneic Tx group, or Balb/c mice as an allogeneic model (allogeneic Tx group. 18F-DPA-714-PET was used to determine the uptake ratio, calculated as the maximum standardized uptake value in the anterior and septal wall of the LV. The uptake ratio was significantly higher in the allogeneic Tx group than in the syngeneic group or the sham group at days 7 and day 10 after the cell transplantation. In addition, the immunochemistry showed significant presence of CD68 and CD3-positive cells at day 7 and 10 in the transplanted graft of the allogeneic Tx group. The expression of TSPO, CD68, IL-1 beta, and MCP-1 was significantly higher in the allogeneic Tx group than in the syngeneic Tx and the sham groups at day 7. The 18F-DPA-714-PET imaging study enabled quantitative visualization of the macrophages-mediated immune

  17. Registered error between PET and CT images confirmed by a water model

    International Nuclear Information System (INIS)

    Chen Yangchun; Fan Mingwu; Xu Hao; Chen Ping; Zhang Chunlin

    2012-01-01

    The registered error between PET and CT imaging system was confirmed by a water model simulating clinical cases. A barrel of 6750 mL was filled with 59.2 MBq [ 18 F]-FDG and scanned after 80 min by 2 dimension model PET/CT. The CT images were used to attenuate the PET images. The CT/PET images were obtained by image morphological processing analyses without barrel wall. The relationship of the water image centroids of CT and PET images was established by linear regression analysis, and the registered error between PET and CT image could be computed one slice by one slice. The alignment program was done 4 times following the protocol given by GE Healthcare. Compared with centroids of water CT images, centroids of PET images were shifted to X-axis (0.011slice+0.63) mm, to Y-axis (0.022×slice+1.35) mm. To match CT images, PET images should be translated along X-axis (-2.69±0.15) mm, Y-axis (0.43±0.11) mm, Z-axis (0.86±0.23) mm, and X-axis be rotated by (0.06±0.07)°, Y-axis by (-0.01±0.08)°, and Z-axis by (0.11±0.07)°. So, the systematic registered error was not affected by load and its distribution. By finding the registered error between PET and CT images for coordinate rotation random error, the water model could confirm the registered results of PET-CT system corrected by Alignment parameters. (authors)

  18. Clinical evaluation of PET image reconstruction using a spatial resolution model

    DEFF Research Database (Denmark)

    Andersen, Flemming Littrup; Klausen, Thomas Levin; Loft, Annika

    2013-01-01

    PURPOSE: PET image resolution is variable across the measured field-of-view and described by the point spread function (PSF). When accounting for the PSF during PET image reconstruction image resolution is improved and partial volume effects are reduced. Here, we evaluate the effect of PSF......-based reconstruction on lesion quantification in routine clinical whole-body (WB) PET/CT imaging. MATERIALS AND METHODS: 41 oncology patients were referred for a WB-PET/CT examination (Biograph 40 TruePoint). Emission data were acquired at 2.5min/bed at 1hpi of 400 MBq [18F]-FDG. Attenuation-corrected PET images were...... reconstructed on 336×336-matrices using: (R1) standard AW-OSEM (4 iter, 8 subsets, 4mm Gaussian) and (R2) AW-OSEM with PSF (3 iter, 21 subsets, 2mm). Blinded and randomised reading of R1- and R2-PET images was performed. Individual lesions were located and counted independently on both sets of images...

  19. The four-dimensional non-uniform rational B-splines-based cardiac-torso phantom and its application in medical imaging research

    International Nuclear Information System (INIS)

    Li Chongguo; Wu Dake; Lang Jinyi

    2008-01-01

    Simulation skill is playing an increasingly important role in medical imaging research. four-dimensional non-uniform rational B-splines-based cardiac-torso (4D NCAT) phantom is new tool for meoical imaging res catch and when combined with accurate models for the imaging process a wealth of realistic imaging data from subjects of various anatomies. Can be provided 4D NCAT phantoms have bend widely used in medical research such as SPECT, PET, CT and so on. 4D NCAT phantoms have also been used in inverse planning system of intensity modulated radiation therapy. (authors)

  20. Towards integration of PET/MR hybrid imaging into radiation therapy treatment planning

    International Nuclear Information System (INIS)

    Paulus, Daniel H.; Thorwath, Daniela; Schmidt, Holger; Quick, Harald H.

    2014-01-01

    Purpose: Multimodality imaging has become an important adjunct of state-of-the-art radiation therapy (RT) treatment planning. Recently, simultaneous PET/MR hybrid imaging has become clinically available and may also contribute to target volume delineation and biological individualization in RT planning. For integration of PET/MR hybrid imaging into RT treatment planning, compatible dedicated RT devices are required for accurate patient positioning. In this study, prototype RT positioning devices intended for PET/MR hybrid imaging are introduced and tested toward PET/MR compatibility and image quality. Methods: A prototype flat RT table overlay and two radiofrequency (RF) coil holders that each fix one flexible body matrix RF coil for RT head/neck imaging have been evaluated within this study. MR image quality with the RT head setup was compared to the actual PET/MR setup with a dedicated head RF coil. PET photon attenuation and CT-based attenuation correction (AC) of the hardware components has been quantitatively evaluated by phantom scans. Clinical application of the new RT setup in PET/MR imaging was evaluated in anin vivo study. Results: The RT table overlay and RF coil holders are fully PET/MR compatible. MR phantom and volunteer imaging with the RT head setup revealed high image quality, comparable to images acquired with the dedicated PET/MR head RF coil, albeit with 25% reduced SNR. Repositioning accuracy of the RF coil holders was below 1 mm. PET photon attenuation of the RT table overlay was calculated to be 3.8% and 13.8% for the RF coil holders. With CT-based AC of the devices, the underestimation error was reduced to 0.6% and 0.8%, respectively. Comparable results were found within the patient study. Conclusions: The newly designed RT devices for hybrid PET/MR imaging are PET and MR compatible. The mechanically rigid design and the reproducible positioning allow for straightforward CT-based AC. The systematic evaluation within this study provides the

  1. Molecular imaging of small animals with dedicated PET tomographs

    International Nuclear Information System (INIS)

    Chatziioannou, A.F.

    2002-01-01

    Biological discovery has moved at an accelerated pace in recent years, with a considerable focus on the transition from in vitro to in vivo models. As a result, there has been a significant increase in the need to adapt clinical imaging methods, as well as for novel imaging technologies for biological research. Positron emission tomography (PET) is a clinical imaging modality that permits the use of positron-labeled molecular imaging probes for non-invasive assays of biochemical processes. The imaging procedure can be repeatedly performed before and after interventions, thereby allowing each animal to be used as its own control. Positron-labeled compounds that target a range of molecular targets have been and continue to be synthesized, with examples of biological processes ranging from receptors and synthesis of transmitters in cell communication, to metabolic processes and gene expression. In animal research, PET has been used extensively in the past for studies of non-human primates and other larger animals. New detector technology has improved spatial resolution, and has made possible PET scanning for the study of the most important modern molecular biology model, the laboratory mouse. This paper presents the challenges facing PET technology as applied to small animal imaging, provides a historical overview of the development of small animal PET systems, and discusses the current state of the art in small animal PET technology. (orig.)

  2. PET-based molecular imaging in neuroscience

    International Nuclear Information System (INIS)

    Jacobs, A.H.; Heiss, W.D.; Li, H.; Knoess, C.; Schaller, B.; Kracht, L.; Monfared, P.; Vollmar, S.; Bauer, B.; Wagner, R.; Graf, R.; Wienhard, K.; Winkeler, A.; Rueger, A.; Klein, M.; Hilker, R.; Galldiks, N.; Herholz, K.; Sobesky, J.

    2003-01-01

    Positron emission tomography (PET) allows non-invasive assessment of physiological, metabolic and molecular processes in humans and animals in vivo. Advances in detector technology have led to a considerable improvement in the spatial resolution of PET (1-2 mm), enabling for the first time investigations in small experimental animals such as mice. With the developments in radiochemistry and tracer technology, a variety of endogenously expressed and exogenously introduced genes can be analysed by PET. This opens up the exciting and rapidly evolving field of molecular imaging, aiming at the non-invasive localisation of a biological process of interest in normal and diseased cells in animal models and humans in vivo. The main and most intriguing advantage of molecular imaging is the kinetic analysis of a given molecular event in the same experimental subject over time. This will allow non-invasive characterisation and ''phenotyping'' of animal models of human disease at various disease stages, under certain pathophysiological stimuli and after therapeutic intervention. The potential broad applications of imaging molecular events in vivo lie in the study of cell biology, biochemistry, gene/protein function and regulation, signal transduction, transcriptional regulation and characterisation of transgenic animals. Most importantly, molecular imaging will have great implications for the identification of potential molecular therapeutic targets, in the development of new treatment strategies, and in their successful implementation into clinical application. Here, the potential impact of molecular imaging by PET in applications in neuroscience research with a special focus on neurodegeneration and neuro-oncology is reviewed. (orig.)

  3. Automatic anatomy recognition in whole-body PET/CT images

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Huiqian [College of Optoelectronic Engineering, Chongqing University, Chongqing 400044, China and Medical Image Processing Group Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States); Udupa, Jayaram K., E-mail: jay@mail.med.upenn.edu; Odhner, Dewey; Tong, Yubing; Torigian, Drew A. [Medical Image Processing Group Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States); Zhao, Liming [Medical Image Processing Group Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 and Research Center of Intelligent System and Robotics, Chongqing University of Posts and Telecommunications, Chongqing 400065 (China)

    2016-01-15

    Purpose: Whole-body positron emission tomography/computed tomography (PET/CT) has become a standard method of imaging patients with various disease conditions, especially cancer. Body-wide accurate quantification of disease burden in PET/CT images is important for characterizing lesions, staging disease, prognosticating patient outcome, planning treatment, and evaluating disease response to therapeutic interventions. However, body-wide anatomy recognition in PET/CT is a critical first step for accurately and automatically quantifying disease body-wide, body-region-wise, and organwise. This latter process, however, has remained a challenge due to the lower quality of the anatomic information portrayed in the CT component of this imaging modality and the paucity of anatomic details in the PET component. In this paper, the authors demonstrate the adaptation of a recently developed automatic anatomy recognition (AAR) methodology [Udupa et al., “Body-wide hierarchical fuzzy modeling, recognition, and delineation of anatomy in medical images,” Med. Image Anal. 18, 752–771 (2014)] to PET/CT images. Their goal was to test what level of object localization accuracy can be achieved on PET/CT compared to that achieved on diagnostic CT images. Methods: The authors advance the AAR approach in this work in three fronts: (i) from body-region-wise treatment in the work of Udupa et al. to whole body; (ii) from the use of image intensity in optimal object recognition in the work of Udupa et al. to intensity plus object-specific texture properties, and (iii) from the intramodality model-building-recognition strategy to the intermodality approach. The whole-body approach allows consideration of relationships among objects in different body regions, which was previously not possible. Consideration of object texture allows generalizing the previous optimal threshold-based fuzzy model recognition method from intensity images to any derived fuzzy membership image, and in the process

  4. Automatic anatomy recognition in whole-body PET/CT images

    International Nuclear Information System (INIS)

    Wang, Huiqian; Udupa, Jayaram K.; Odhner, Dewey; Tong, Yubing; Torigian, Drew A.; Zhao, Liming

    2016-01-01

    Purpose: Whole-body positron emission tomography/computed tomography (PET/CT) has become a standard method of imaging patients with various disease conditions, especially cancer. Body-wide accurate quantification of disease burden in PET/CT images is important for characterizing lesions, staging disease, prognosticating patient outcome, planning treatment, and evaluating disease response to therapeutic interventions. However, body-wide anatomy recognition in PET/CT is a critical first step for accurately and automatically quantifying disease body-wide, body-region-wise, and organwise. This latter process, however, has remained a challenge due to the lower quality of the anatomic information portrayed in the CT component of this imaging modality and the paucity of anatomic details in the PET component. In this paper, the authors demonstrate the adaptation of a recently developed automatic anatomy recognition (AAR) methodology [Udupa et al., “Body-wide hierarchical fuzzy modeling, recognition, and delineation of anatomy in medical images,” Med. Image Anal. 18, 752–771 (2014)] to PET/CT images. Their goal was to test what level of object localization accuracy can be achieved on PET/CT compared to that achieved on diagnostic CT images. Methods: The authors advance the AAR approach in this work in three fronts: (i) from body-region-wise treatment in the work of Udupa et al. to whole body; (ii) from the use of image intensity in optimal object recognition in the work of Udupa et al. to intensity plus object-specific texture properties, and (iii) from the intramodality model-building-recognition strategy to the intermodality approach. The whole-body approach allows consideration of relationships among objects in different body regions, which was previously not possible. Consideration of object texture allows generalizing the previous optimal threshold-based fuzzy model recognition method from intensity images to any derived fuzzy membership image, and in the process

  5. PET/MR imaging of bone lesions - implications for PET quantification from imperfect attenuation correction

    International Nuclear Information System (INIS)

    Samarin, Andrei; Burger, Cyrill; Crook, David W.; Burger, Irene A.; Schmid, Daniel T.; Schulthess, Gustav K. von; Kuhn, Felix P.; Wollenweber, Scott D.

    2012-01-01

    Accurate attenuation correction (AC) is essential for quantitative analysis of PET tracer distribution. In MR, the lack of cortical bone signal makes bone segmentation difficult and may require implementation of special sequences. The purpose of this study was to evaluate the need for accurate bone segmentation in MR-based AC for whole-body PET/MR imaging. In 22 patients undergoing sequential PET/CT and 3-T MR imaging, modified CT AC maps were produced by replacing pixels with values of >100 HU, representing mostly bone structures, by pixels with a constant value of 36 HU corresponding to soft tissue, thereby simulating current MR-derived AC maps. A total of 141 FDG-positive osseous lesions and 50 soft-tissue lesions adjacent to bones were evaluated. The mean standardized uptake value (SUVmean) was measured in each lesion in PET images reconstructed once using the standard AC maps and once using the modified AC maps. Subsequently, the errors in lesion tracer uptake for the modified PET images were calculated using the standard PET image as a reference. Substitution of bone by soft tissue values in AC maps resulted in an underestimation of tracer uptake in osseous and soft tissue lesions adjacent to bones of 11.2 ± 5.4 % (range 1.5-30.8 %) and 3.2 ± 1.7 % (range 0.2-4 %), respectively. Analysis of the spine and pelvic osseous lesions revealed a substantial dependence of the error on lesion composition. For predominantly sclerotic spine lesions, the mean underestimation was 15.9 ± 3.4 % (range 9.9-23.5 %) and for osteolytic spine lesions, 7.2 ± 1.7 % (range 4.9-9.3 %), respectively. CT data simulating treating bone as soft tissue as is currently done in MR maps for PET AC leads to a substantial underestimation of tracer uptake in bone lesions and depends on lesion composition, the largest error being seen in sclerotic lesions. Therefore, depiction of cortical bone and other calcified areas in MR AC maps is necessary for accurate quantification of tracer uptake

  6. CYBPET: a cylindrical PET system for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Karimian, A. [Amirkabir University of Technology, Tehran (Iran, Islamic Republic of) and Nuclear Research Center for Agriculture and Medicine (NRCAM-AEOI), P.O. BOX. (31485-498), Karaj, Iran, Islamic Republic of and Department of Experimental Medicine and Pathology, University of Rome, La Sapienza, Rome (Italy)]. E-mail: akarimian@nrcam.org; Thompson, C.J. [Montreal Neurological Institute, McGill University, Montreal QC (Canada); Sarkar, S. [Medical physics Department of Tehran University of Medical Sciences and (RCSTIM), Tehran (Iran, Islamic Republic of); Raisali, G. [Nuclear Research Center for Agriculture and Medicine (NRCAM-AEOI), P.O. BOX. (31485-498), Karaj (Iran, Islamic Republic of); Pani, R. [Department of Experimental Medicine and Pathology, University of Rome La Sapienza, Rome (Italy); Davilu, H. [Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Sardari, D. [Amirkabir University of Technology, Tehran (Iran, Islamic Republic of)

    2005-06-11

    We propose a Cylindrical Breast PET (CYBPET) system for breast imaging with patients in the prone position. An individual pendulous breast is covered by thin plastic to provide reduced pressure fixation and surrounded by the crystals inside the CYBPET ring. Each breast is imaged separately. The rest of the body is shielded properly to minimize the contribution of scattered photons from the other breast and the rest of the body. To compare the CYBPET with whole-body PET (WB-PET) the simulations of CYBPET and a WB-PET (GE-Advance) for a 10 mm tumor inside the breast with a lesion to background (breast) activity concentration of 6 to 1 were made. The noise effective count rate (NECR) of CYBPET is about twice that of WB-PET at activity concentrations less than 3.1 {mu}Ci/cc. The spatial resolution of CYBPET is better by 25% than the WB-PET.

  7. CYBPET: a cylindrical PET system for breast imaging

    International Nuclear Information System (INIS)

    Karimian, A.; Thompson, C.J.; Sarkar, S.; Raisali, G.; Pani, R.; Davilu, H.; Sardari, D.

    2005-01-01

    We propose a Cylindrical Breast PET (CYBPET) system for breast imaging with patients in the prone position. An individual pendulous breast is covered by thin plastic to provide reduced pressure fixation and surrounded by the crystals inside the CYBPET ring. Each breast is imaged separately. The rest of the body is shielded properly to minimize the contribution of scattered photons from the other breast and the rest of the body. To compare the CYBPET with whole-body PET (WB-PET) the simulations of CYBPET and a WB-PET (GE-Advance) for a 10 mm tumor inside the breast with a lesion to background (breast) activity concentration of 6 to 1 were made. The noise effective count rate (NECR) of CYBPET is about twice that of WB-PET at activity concentrations less than 3.1 μCi/cc. The spatial resolution of CYBPET is better by 25% than the WB-PET

  8. Semi-Supervised Tripled Dictionary Learning for Standard-dose PET Image Prediction using Low-dose PET and Multimodal MRI

    Science.gov (United States)

    Wang, Yan; Ma, Guangkai; An, Le; Shi, Feng; Zhang, Pei; Lalush, David S.; Wu, Xi; Pu, Yifei; Zhou, Jiliu; Shen, Dinggang

    2017-01-01

    Objective To obtain high-quality positron emission tomography (PET) image with low-dose tracer injection, this study attempts to predict the standard-dose PET (S-PET) image from both its low-dose PET (L-PET) counterpart and corresponding magnetic resonance imaging (MRI). Methods It was achieved by patch-based sparse representation (SR), using the training samples with a complete set of MRI, L-PET and S-PET modalities for dictionary construction. However, the number of training samples with complete modalities is often limited. In practice, many samples generally have incomplete modalities (i.e., with one or two missing modalities) that thus cannot be used in the prediction process. In light of this, we develop a semi-supervised tripled dictionary learning (SSTDL) method for S-PET image prediction, which can utilize not only the samples with complete modalities (called complete samples) but also the samples with incomplete modalities (called incomplete samples), to take advantage of the large number of available training samples and thus further improve the prediction performance. Results Validation was done on a real human brain dataset consisting of 18 subjects, and the results show that our method is superior to the SR and other baseline methods. Conclusion This work proposed a new S-PET prediction method, which can significantly improve the PET image quality with low-dose injection. Significance The proposed method is favorable in clinical application since it can decrease the potential radiation risk for patients. PMID:27187939

  9. Present and future of clinical cardiovascular PET imaging in Europe - a position statement by the European Council of Nuclear Cardiology (ECNC)

    International Nuclear Information System (INIS)

    Le Guludec, D.; Lautamaeki, R.; Bengel, F.M.; Knuuti, J.; Bax, J.J.

    2008-01-01

    This position statement was prepared by the European Council of Nuclear Cardiology and summarises the current and future potential of PET as a clinical cardiovascular diagnostic imaging tool. The first section describes how methodological developments have positively influenced the transition of PET from a research tool towards a clinical diagnostic test. In the second section, evidence in support of its superior diagnostic accuracy, its value to guide decision making and to predict outcome and its cost effectiveness is summarised. The third section finally outlines new PET-based approaches and concepts, which will likely influence clinical cardiovascular medicine in the future. The notion that integration of cardiac PET into healthcare systems and disease management algorithms will advance quality of care is increasingly supported by the literature highlighted in this statement. (orig.)

  10. PET in tumor imaging: research only or a cost effective clinical tool?

    International Nuclear Information System (INIS)

    Wahl, R.L.

    1997-01-01

    PET imaging has for many years been a versatile tool for non-invasive imaging of neuro-physiology and, indeed, whole body physiology. Quantitative PET imaging of trace amounts of radioactivity is scientifically elegant and can be very complex. This lecture focuses on whether and where this test is clinically useful. Because of the research tradition, PET imaging has been perceived as an 'expensive' test, as it costs more per scan than CT and MRI scans at most institutions. Such a superficial analysis is incorrect, however, as it is increasingly recognized that imaging costs, which in some circumstances will be increased by the use of PET, are only a relatively small component of patient care costs. Thus, PET may raise imaging costs and the number of imaging procedures in some settings, though PET may reduce imaging test numbers in other settings. However, the analysis must focus on the total costs of patient management. Analyses focused on total patient care costs, including cost of hospitalization and cost surgery as well as imaging costs, have shown that PET can substantially reduce total patient care costs in several settings. This is achieved by providing a more accurate diagnosis, and thus having fewer instances of an incorrect diagnosis resulting in subsequent inappropriate surgery or investigations. Several institutions have shown scenarios in which PET for tumor imaging is cost effective. While the specific results of the analyses vary based on disease prevalence and cost input values for each procedure, as well as the projected performance of PET, the similar results showing total care cost savings in the management of several common cancers, strongly supports the rational for the use of PET in cancer management. In addition, promising clinical results are forthcoming in several other illnesses, suggesting PET will have broader utility than these uses, alone. Thus, while PET is an 'expensive' imaging procedure and has considerable utility as a research

  11. PET imaging in breast cancer

    International Nuclear Information System (INIS)

    Bombardieri, E.; Crippa, F.

    2001-01-01

    The basis of tumour imaging with PET is a specific uptake mechanism of positron emitting radiopharmaceuticals. Among the potential tracers for breast cancer (fluorodeoxyglucose, methionine, tyrosine, fluoro-estradiol, nor-progesterone), 2-deoxy-2-fluoro-D-glucose labelled with fluorine (FDG) is the most widely used radiopharmaceutical because breast cancer is particularly avid of FDG and 18 F has the advantages of the a relatively long physical half-life. Mammography is the first choice examination in studying breast masses, due to its very good performances, an excellent compliance and the best value regarding the cost/effectiveness aspects. The FDG uptake in tissue correlates with the histological grade and potential aggressiveness of breast cancer and this may have prognostic consequences. Besides the evaluation of breast lesions, FDG-PET shows a great efficacy in staging lymph node involvement prior surgery and this could have a great value in loco-regional staging. Whole body PET provides also information with regard to metastasis localizations both in soft tissue and bone, and plays an important clinical role mainly in detecting recurrent metastatic disease. In fact for its metabolic characteristics PET visualizes regions of enhanced metabolic activity and can complete other imaging modalities based on structural anatomic changes. Even though CT and MRI show superior resolution characteristics, it has been demonstrated that PET provides more accurate information in discriminating between viable tumour, fibrotic scar or necrosis. These statements are coming from the examination of more than 2000 breast cancer detection

  12. Imaging performance of LabPET APD-based digital PET scanners for pre-clinical research

    International Nuclear Information System (INIS)

    Bergeron, Mélanie; Cadorette, Jules; Beaudoin, Jean-François; Lecomte, Roger; Tétrault, Marc-André; Leroux, Jean-Daniel; Fontaine, Réjean

    2014-01-01

    The LabPET is an avalanche photodiode (APD) based digital PET scanner with quasi-individual detector read-out and highly parallel electronic architecture for high-performance in vivo molecular imaging of small animals. The scanner is based on LYSO and LGSO scintillation crystals (2×2×12/14 mm 3 ), assembled side-by-side in phoswich pairs read out by an APD. High spatial resolution is achieved through the individual and independent read-out of an individual APD detector for recording impinging annihilation photons. The LabPET exists in three versions, LabPET4 (3.75 cm axial length), LabPET8 (7.5 cm axial length) and LabPET12 (11.4 cm axial length). This paper focuses on the systematic characterization of the three LabPET versions using two different energy window settings to implement a high-efficiency mode (250–650 keV) and a high-resolution mode (350–650 keV) in the most suitable operating conditions. Prior to measurements, a global timing alignment of the scanners and optimization of the APD operating bias have been carried out. Characteristics such as spatial resolution, absolute sensitivity, count rate performance and image quality have been thoroughly investigated following the NEMA NU 4-2008 protocol. Phantom and small animal images were acquired to assess the scanners' suitability for the most demanding imaging tasks in preclinical biomedical research. The three systems achieve the same radial FBP spatial resolution at 5 mm from the field-of-view center: 1.65/3.40 mm (FWHM/FWTM) for an energy threshold of 250 keV and 1.51/2.97 mm for an energy threshold of 350 keV. The absolute sensitivity for an energy window of 250–650 keV is 1.4%/2.6%/4.3% for LabPET4/8/12, respectively. The best count rate performance peaking at 362 kcps is achieved by the LabPET12 with an energy window of 250–650 keV and a mouse phantom (2.5 cm diameter) at an activity of 2.4 MBq ml −1 . With the same phantom, the scatter fraction for all scanners is about

  13. Comparative cardiac imaging

    International Nuclear Information System (INIS)

    Brundage, B.H.

    1990-01-01

    This book is designed to compare all major cardiac imaging techniques. All major imaging techniques - including conventional angiography, digital angiography, echocardiography and Doppler imaging, conventional radioisotope techniques, computed tomography, and magnetic resonance imaging - are covered in this text as they apply to the major cardiovascular disorders. There is brief coverage of positron emission tomography and an extensive presentation of ultrafast computed tomography

  14. Cardiac imaging in adults

    International Nuclear Information System (INIS)

    Jaffe, C.C.

    1987-01-01

    This book approaches adult cardiac disease from the correlative imaging perspective. It includes chest X-rays and angiographs, 2-dimensional echocardiograms with explanatory diagrams for clarity, plus details on digital radiology, nuclear medicine techniques, CT and MRI. It also covers the normal heart, valvular heart disease, myocardial disease, pericardial disease, bacterial endocarditis, aortic aneurysm, cardiac tumors, and congenital heart disease of the adult. It points out those aspects where one imaging technique has significant superiority

  15. Cardiac imaging in adults

    Energy Technology Data Exchange (ETDEWEB)

    Jaffe, C.C.

    1987-01-01

    This book approaches adult cardiac disease from the correlative imaging perspective. It includes chest X-rays and angiographs, 2-dimensional echocardiograms with explanatory diagrams for clarity, plus details on digital radiology, nuclear medicine techniques, CT and MRI. It also covers the normal heart, valvular heart disease, myocardial disease, pericardial disease, bacterial endocarditis, aortic aneurysm, cardiac tumors, and congenital heart disease of the adult. It points out those aspects where one imaging technique has significant superiority.

  16. Non-local means denoising of dynamic PET images.

    Directory of Open Access Journals (Sweden)

    Joyita Dutta

    Full Text Available Dynamic positron emission tomography (PET, which reveals information about both the spatial distribution and temporal kinetics of a radiotracer, enables quantitative interpretation of PET data. Model-based interpretation of dynamic PET images by means of parametric fitting, however, is often a challenging task due to high levels of noise, thus necessitating a denoising step. The objective of this paper is to develop and characterize a denoising framework for dynamic PET based on non-local means (NLM.NLM denoising computes weighted averages of voxel intensities assigning larger weights to voxels that are similar to a given voxel in terms of their local neighborhoods or patches. We introduce three key modifications to tailor the original NLM framework to dynamic PET. Firstly, we derive similarities from less noisy later time points in a typical PET acquisition to denoise the entire time series. Secondly, we use spatiotemporal patches for robust similarity computation. Finally, we use a spatially varying smoothing parameter based on a local variance approximation over each spatiotemporal patch.To assess the performance of our denoising technique, we performed a realistic simulation on a dynamic digital phantom based on the Digimouse atlas. For experimental validation, we denoised [Formula: see text] PET images from a mouse study and a hepatocellular carcinoma patient study. We compared the performance of NLM denoising with four other denoising approaches - Gaussian filtering, PCA, HYPR, and conventional NLM based on spatial patches.The simulation study revealed significant improvement in bias-variance performance achieved using our NLM technique relative to all the other methods. The experimental data analysis revealed that our technique leads to clear improvement in contrast-to-noise ratio in Patlak parametric images generated from denoised preclinical and clinical dynamic images, indicating its ability to preserve image contrast and high

  17. Non-local means denoising of dynamic PET images.

    Science.gov (United States)

    Dutta, Joyita; Leahy, Richard M; Li, Quanzheng

    2013-01-01

    Dynamic positron emission tomography (PET), which reveals information about both the spatial distribution and temporal kinetics of a radiotracer, enables quantitative interpretation of PET data. Model-based interpretation of dynamic PET images by means of parametric fitting, however, is often a challenging task due to high levels of noise, thus necessitating a denoising step. The objective of this paper is to develop and characterize a denoising framework for dynamic PET based on non-local means (NLM). NLM denoising computes weighted averages of voxel intensities assigning larger weights to voxels that are similar to a given voxel in terms of their local neighborhoods or patches. We introduce three key modifications to tailor the original NLM framework to dynamic PET. Firstly, we derive similarities from less noisy later time points in a typical PET acquisition to denoise the entire time series. Secondly, we use spatiotemporal patches for robust similarity computation. Finally, we use a spatially varying smoothing parameter based on a local variance approximation over each spatiotemporal patch. To assess the performance of our denoising technique, we performed a realistic simulation on a dynamic digital phantom based on the Digimouse atlas. For experimental validation, we denoised [Formula: see text] PET images from a mouse study and a hepatocellular carcinoma patient study. We compared the performance of NLM denoising with four other denoising approaches - Gaussian filtering, PCA, HYPR, and conventional NLM based on spatial patches. The simulation study revealed significant improvement in bias-variance performance achieved using our NLM technique relative to all the other methods. The experimental data analysis revealed that our technique leads to clear improvement in contrast-to-noise ratio in Patlak parametric images generated from denoised preclinical and clinical dynamic images, indicating its ability to preserve image contrast and high intensity details while

  18. Multiphase contrast-enhanced CT with highly concentrated contrast agent can be used for PET attenuation correction in integrated PET/CT imaging

    International Nuclear Information System (INIS)

    Aschoff, Philip; Plathow, Christian; Lichy, Matthias P.; Claussen, Claus D.; Pfannenberg, Christina; Beyer, Thomas; Erb, Gunter; Oeksuez, Mehmet Oe.

    2012-01-01

    State-of-the-art positron emission tomography/computed tomography (PET/CT) systems incorporate multislice CT technology, thus facilitating the acquisition of multiphase, contrast-enhanced CT data as part of integrated PET/CT imaging protocols. We assess the influence of a highly concentrated iodinated contrast medium (CM) on quantification and image quality following CT-based attenuation correction (CT-AC) in PET/CT. Twenty-eight patients with suspected malignant liver lesions were enrolled prospectively. PET/CT was performed 60 min after injection of 400 MBq of 18 F-fluorodeoxyglucose (FDG) and following the biphasic administration of an intravenous CM (400 mg iodine/ml, Iomeron 400). PET images were reconstructed with CT-AC using any of four acquired CT image sets: non-enhanced, pre-contrast (n-PET), arterial phase (art-PET), portal venous phase (pv-PET) and late phase (late-PET). Normal tissue activity and liver lesions were assessed visually and quantitatively on each PET/CT image set. Visual assessment of PET following CT-AC revealed no noticeable difference in image appearance or quality when using any of the four CT data sets for CT-AC. A total of 44 PET-positive liver lesions was identified in 21 of 28 patients. There were no false-negative or false-positive lesions on PET. Mean standardized uptake values (SUV) in 36 evaluable lesions were: 5.5 (n-PET), 5.8 (art-PET), 5.8 (pv-PET) and 5.8 (late-PET), with the highest mean increase in mean SUV of 6%. Mean SUV changes in liver background increased by up to 10% from n-PET to pv-PET. Multiphase CT data acquired with the use of highly concentrated CM can be used for qualitative assessment of liver lesions in torso FDG PET/CT. The influence on quantification of FDG uptake is small and negligible for most clinical applications. (orig.)

  19. 11C-Choline PET/pathology image coregistration in primary localized prostate cancer

    International Nuclear Information System (INIS)

    Grosu, Anca-Ligia; Prokic, Vesna; Weirich, Gregor; Wendl, Christina; Geinitz, Hans; Molls, Michael; Kirste, Simon; Souvatzoglou, Michael; Schwaiger, Markus; Gschwend, Juergen E.; Treiber, Uwe; Weber, Wolfgang A.; Krause, Bernd Joachim

    2014-01-01

    The aim of this study was to develop a methodology for the comparison of pathology specimens after prostatectomy (post-S) with PET images obtained before surgery (pre-S). This method was used to evaluate the merit of 11 C-choline PET/CT for delineation of gross tumour volume (GTV) in prostate cancer (PC). In 28 PC patients, 11 C-choline PET/CT was performed before surgery. PET/CT data were coregistered with the pathology specimens. GTV on PET images (GTV-PET) was outlined automatically and corrected manually. Tumour volume in the prostate (TVP) was delineated manually on the pathology specimens. Based on the coregistered PET/pathology images, the following parameters were assessed: SUVmax and SUVmean in the tumoral and nontumoral prostate (NP), GTV-PET (millilitres) and TVP (millilitres). PET/pathology image coregistration was satisfactory. Mean SUVmax in the TVP was lower than in the NP: 5.0 and 5.5, respectively (p = 0.093). Considering the entire prostate, SUVmax was located in the TVP in two patients, in the TVP and NP in 12 patients and exclusively in NP in 14 patients. Partial overlap the TVP and GTV-PET was seen in 71 % of patients, and complete overlap in 4 %. PET/pathology image coregistration can be used for evaluation of different imaging modalities. 11 C-Choline PET failed to distinguish tumour from nontumour tissue. (orig.)

  20. New perspective in high tech radiotherapy planning using PET/CT images (Radiation oncologist's view on PET/CT usage)

    International Nuclear Information System (INIS)

    Hadjieva, T.; Bildirev, N.; Koleva, I.; Zahariev, Z.; Vasileva, V.; Encheva, E.; Sultanov, B.

    2010-01-01

    Biological images provided by 18F-FDG PET in combination with structural X ray picture currently offer the most accurate available information on tumour staging, curative antitumour effect for prognosis, impairment of organ function after treatment, as well as primary tumour detection in unknown primary metastatic disease. The authors as radiation oncologists critically have analyzed numerous clinical trials and two guidelines to prove PET/ CT benefit in radiotherapy practice. At present they found lack of scientific evidence to confirm that patient outcomes are superior as a result of the use of PET in RT planning. PET/CT offers a best image for tumour delineation only in some cases of lung cancer, mediastinal lymph nodes and malignant lymphomas. 11C methionin PET adds additional information on postoperative MRI image for brain tumours. Inflammation as postradiation phenomenon, as well as physiological organ movements leads to false-positive PET signal. High tech radiotherapy methods require delineation on precise images given after multidisciplinary team expertise - a practice that is possible only in clinical trials, These unsolved problems have raised many ethical challenges in medical, scientific and social aspect, if wide and routine use of FDG-PET u PET/CT is advocated. (authors)

  1. Influence of image reconstruction methods on statistical parametric mapping of brain PET images

    International Nuclear Information System (INIS)

    Yin Dayi; Chen Yingmao; Yao Shulin; Shao Mingzhe; Yin Ling; Tian Jiahe; Cui Hongyan

    2007-01-01

    Objective: Statistic parametric mapping (SPM) was widely recognized as an useful tool in brain function study. The aim of this study was to investigate if imaging reconstruction algorithm of PET images could influence SPM of brain. Methods: PET imaging of whole brain was performed in six normal volunteers. Each volunteer had two scans with true and false acupuncturing. The PET scans were reconstructed using ordered subsets expectation maximization (OSEM) and filtered back projection (FBP) with 3 varied parameters respectively. The images were realigned, normalized and smoothed using SPM program. The difference between true and false acupuncture scans was tested using a matched pair t test at every voxel. Results: (1) SPM corrected multiple comparison (P corrected uncorrected <0.001): SPM derived from the images with different reconstruction method were different. The largest difference, in number and position of the activated voxels, was noticed between FBP and OSEM re- construction algorithm. Conclusions: The method of PET image reconstruction could influence the results of SPM uncorrected multiple comparison. Attention should be paid when the conclusion was drawn using SPM uncorrected multiple comparison. (authors)

  2. Dual modality CT/PET imaging in lung cancer staging

    International Nuclear Information System (INIS)

    Diaz, Gabriel A.

    2005-01-01

    Purpose: To compare the diagnostic capability of PET-HCT image fusion and helical computed tomography (HCT) for nodal and distant metastases detection in patients with lung cancer. Material and methods: Between February, 2003 and March, 2004 sixty-six consecutive lung cancer patients (45 men and 21 women, mean ages: 63 years old, range: 38 to 96 years old) who underwent HCT and PET-HCT fusion imaging were evaluated retrospectively. All patients had histological confirmation of lung cancer and a definitive diagnosis established on the basis of pathology results and/or clinical follow-up. Results: For global nodal staging (hilar and mediastinal) HCT showed a sensitivity, specificity, positive predictive value and negative predictive value of 72%, 47%, 62% and 58% respectively, versus 94%, 77%, 83% and 92% corresponding to PET-HCT examination. For assessment of advanced nodal stage (N3) PET-HCT showed values of 92%, 100%, 100% and 98% respectively. For detection of distant metastasis, HCT alone had values of 67%, 93%, 84% and 83% respectively versus 100%, 98%, 96% and 100% for the PET-HCT fusion imaging. In 20 (30%) patients under-staged or over-staged on the basis of HCT results, PET-HCT allowed accurate staging. Conclusions: PET-HCT fusion imaging was more effective than HCT alone for nodal and distant metastasis detection and oncology staging. (author)

  3. Assessment of myocardial metabolic rate of glucose by means of Bayesian ICA and Markov Chain Monte Carlo methods in small animal PET imaging

    Science.gov (United States)

    Berradja, Khadidja; Boughanmi, Nabil

    2016-09-01

    In dynamic cardiac PET FDG studies the assessment of myocardial metabolic rate of glucose (MMRG) requires the knowledge of the blood input function (IF). IF can be obtained by manual or automatic blood sampling and cross calibrated with PET. These procedures are cumbersome, invasive and generate uncertainties. The IF is contaminated by spillover of radioactivity from the adjacent myocardium and this could cause important error in the estimated MMRG. In this study, we show that the IF can be extracted from the images in a rat heart study with 18F-fluorodeoxyglucose (18F-FDG) by means of Independent Component Analysis (ICA) based on Bayesian theory and Markov Chain Monte Carlo (MCMC) sampling method (BICA). Images of the heart from rats were acquired with the Sherbrooke small animal PET scanner. A region of interest (ROI) was drawn around the rat image and decomposed into blood and tissue using BICA. The Statistical study showed that there is a significant difference (p corrupted with spillover.

  4. Technology challenges in small animal PET imaging

    International Nuclear Information System (INIS)

    Lecomte, Roger

    2004-01-01

    Positron Emission Tomography (PET) is a non-invasive nuclear imaging modality allowing biochemical processes to be investigated in vivo with sensitivity in the picomolar range. For this reason, PET has the potential to play a major role in the emerging field of molecular imaging by enabling the study of molecular pathways and genetic processes in living animals non-invasively. The challenge is to obtain a spatial resolution that is appropriate for rat and mouse imaging, the preferred animal models for research in biology, while achieving a sensitivity adequate for real-time measurement of rapid dynamic processes in vivo without violating tracer kinetic principles. An overview of the current state of development of dedicated small animal PET scanners is given, and selected applications are reported and discussed with respect to performance and significance to research in biology

  5. Small Animal [18F]FDG PET Imaging for Tumor Model Study

    International Nuclear Information System (INIS)

    Woo, Sang Keun; Kim, Kyeong Min; Cheon, Gi Jeong

    2008-01-01

    PET allows non-invasive, quantitative and repetitive imaging of biological function in living animals. Small animal PET imaging with [ 18 F]FDG has been successfully applied to investigation of metabolism, receptor, ligand interactions, gene expression, adoptive cell therapy and somatic gene therapy. Experimental condition of animal handling impacts on the biodistribution of [ 18 F]FDG in small animal study. The small animal PET and CT images were registered using the hardware fiducial markers and small animal contour point. Tumor imaging in small animal with small animal [ 18 F]FDG PET should be considered fasting, warming, and isoflurane anesthesia level. Registered imaging with small animal PET and CT image could be useful for the detection of tumor. Small animal experimental condition of animal handling and registration method will be of most importance for small lesion detection of metastases tumor model

  6. Molecular nuclear cardiac imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Soo; Paeng, Jin Chul [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    2004-04-01

    Molecular nuclear cardiac imaging has included Tc-99m Annexin imaging to visualize myocardial apoptosis, but is now usually associated with gene therapy and cell-based therapy. Cardiac gene therapy was not successful so far but cardiac reporter gene imaging was made possible using HSV-TK (herpes simplex virus thymidine kinase) and F-18 FHBG (fluoro-hydroxymethylbutyl guanine) or I-124 FIAU (fluoro-deoxyiodo-arabino-furanosyluracil). Gene delivery was performed by needle injection with or without catheter guidance. TK expression did not last longer than 2 weeks in myocardium. Cell-based therapy of ischemic heart or failing heart looks promising, but biodistribution and differentiation of transplanted cells are not known. Reporter genes can be transfected to the stem/progenitor cells and cells containing these genes can be transplanted to the recipients using catheter-based purging or injection. Repeated imaging should be available and if promoter are varied to let express reporter transgenes, cellular (trans)differentiation can be studied. NIS (sodium iodide symporter) or D2R receptor genes are promising in this aspect.

  7. Molecular nuclear cardiac imaging

    International Nuclear Information System (INIS)

    Lee, Dong Soo; Paeng, Jin Chul

    2004-01-01

    Molecular nuclear cardiac imaging has included Tc-99m Annexin imaging to visualize myocardial apoptosis, but is now usually associated with gene therapy and cell-based therapy. Cardiac gene therapy was not successful so far but cardiac reporter gene imaging was made possible using HSV-TK (herpes simplex virus thymidine kinase) and F-18 FHBG (fluoro-hydroxymethylbutyl guanine) or I-124 FIAU (fluoro-deoxyiodo-arabino-furanosyluracil). Gene delivery was performed by needle injection with or without catheter guidance. TK expression did not last longer than 2 weeks in myocardium. Cell-based therapy of ischemic heart or failing heart looks promising, but biodistribution and differentiation of transplanted cells are not known. Reporter genes can be transfected to the stem/progenitor cells and cells containing these genes can be transplanted to the recipients using catheter-based purging or injection. Repeated imaging should be available and if promoter are varied to let express reporter transgenes, cellular (trans)differentiation can be studied. NIS (sodium iodide symporter) or D2R receptor genes are promising in this aspect

  8. Choline-PET/CT for imaging prostate cancer; Cholin-PET/CT zur Bildgebung des Prostatakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Krause, Bernd Joachim [Klinik- und Poliklinik fuer Nuklearmedizin, Klinikum rechts der Isar, Technische Univ. Muenchen (Germany); Treiber, U.; Schwarzenboeck, S.; Souvatzoglou, M. [Klinik fuer Urologie, Klinikum rechts der Isar, Technische Univ. Muenchen (Germany)

    2010-09-15

    PET and PET/CT using [{sup 11}C]- and [{sup 18}F]-labelled choline derivatives are increasingly being used for imaging of prostate cancer. The value of PET and PET/CT with [{sup 11}C]- and [{sup 18}F]-labelled choline derivates in biochemical recurrence of prostate cancer has been examined in many studies and demonstrates an increasing importance. Primary prostate cancer can be detected with moderate sensitivity using PET and PET/CT using [{sup 11}C]- and [{sup 18}F]-labelled choline derivatives - the differentiation between benign prostatic hyperplasia, prostatitis or high-grade intraepithelial neoplasia (HGPIN) is not always possible. At the present time [{sup 11}C]choline PET/CT is not recommended in the primary setting but may be utilized in clinically suspected prostate cancer with repeatedly negative prostate biopsies, in preparation of a focused re-biopsy. Promising results have been obtained for the use of PET and PET/CT with [{sup 11}C]- and [{sup 18}F]-labelled choline derivates in patients with biochemical recurrence. The detection rate of choline PET and PET/CT for local, regional, and distant recurrence in patients with a biochemical recurrence shows a linear correlation with PSA values at the time of imaging and reaches about 75% in patients with PSA > 3 ng/mL. At PSA values below 1 ng/mL, the recurrence can be diagnosed with choline PET/CT in approximately 1/3 of the patients. PET and PET/CT with [{sup 11}C]- and [{sup 18}F]choline derivates can be helpful for choosing a therapeutic strategy in the sense of an individualized treatment: since an early diagnosis of recurrence is crucial to the choice of optimal treatment. The localization of the site of recurrence - local recurrence, lymph node metastasis or systemic dissemination - has important influence on the therapy regimen. (orig.)

  9. Development of a SiPM-based PET imaging system for small animals

    International Nuclear Information System (INIS)

    Lu, Yanye; Yang, Kun; Zhou, Kedi; Zhang, Qiushi; Pang, Bo; Ren, Qiushi

    2014-01-01

    Advances in small animal positron emission tomography (PET) imaging have been accelerated by many new technologies such as the successful incorporation of silicon photomultiplier (SiPM). In this paper, we have developed a compact, lightweight PET imaging system that is based on SiPM detectors for small animals imaging, which could be integrated into a multi-modality imaging system. This PET imaging system consists of a stationary detector gantry, a motor-controlled animal bed module, electronics modules, and power supply modules. The PET detector, which was designed as a multi-slice circular ring geometry of 27 discrete block detectors, is composed of a cerium doped lutetium–yttrium oxyorthosilicate (LYSO) scintillation crystal and SiPM arrays. The system has a 60 mm transaxial field of view (FOV) and a 26 mm axial FOV. Performance tests (e.g. spatial resolution, energy resolution, and sensitivity) and phantom and animal imaging studies were performed to evaluate the imaging performance of the PET imaging system. The performance tests and animal imaging results demonstrate the feasibility of an animal PET system based on SiPM detectors and indicate that SiPM detectors can be promising photodetectors in animal PET instrumentation development

  10. Development of a SiPM-based PET imaging system for small animals

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Yanye [Department of Biomedicine and Engineering, College of Engineering, Peking University, Beijing 100871 (China); Yang, Kun, E-mail: yangkun9999@hotmail.com [Department of Control Technology and Instrumentation, College of Quality and Technical Supervision, Hebei University, Baoding, 071000 (China); Zhou, Kedi; Zhang, Qiushi; Pang, Bo [Department of Biomedicine and Engineering, College of Engineering, Peking University, Beijing 100871 (China); Ren, Qiushi, E-mail: renqsh@coe.pku.edu.cn [Department of Biomedicine and Engineering, College of Engineering, Peking University, Beijing 100871 (China)

    2014-04-11

    Advances in small animal positron emission tomography (PET) imaging have been accelerated by many new technologies such as the successful incorporation of silicon photomultiplier (SiPM). In this paper, we have developed a compact, lightweight PET imaging system that is based on SiPM detectors for small animals imaging, which could be integrated into a multi-modality imaging system. This PET imaging system consists of a stationary detector gantry, a motor-controlled animal bed module, electronics modules, and power supply modules. The PET detector, which was designed as a multi-slice circular ring geometry of 27 discrete block detectors, is composed of a cerium doped lutetium–yttrium oxyorthosilicate (LYSO) scintillation crystal and SiPM arrays. The system has a 60 mm transaxial field of view (FOV) and a 26 mm axial FOV. Performance tests (e.g. spatial resolution, energy resolution, and sensitivity) and phantom and animal imaging studies were performed to evaluate the imaging performance of the PET imaging system. The performance tests and animal imaging results demonstrate the feasibility of an animal PET system based on SiPM detectors and indicate that SiPM detectors can be promising photodetectors in animal PET instrumentation development.

  11. First PET Center in Mexico: the power of molecular imaging

    International Nuclear Information System (INIS)

    Avila R, M.A.

    2001-01-01

    Positron Emission Tomography (PET) is a non-invasive diagnostic imaging technique modality. It represents the forefront of medical images and was developed as a quantitative technique for imaging biochemical and physiological processes in the human body. PET is unique because it produces images of the body's basic biochemistry or function. Traditional diagnostic techniques such as x-rays, CT scans or MRI, produce images of the body's anatomy or structure. The premise with these techniques is that the change in anatomy or structure that occurs with disease can be seen. However, biochemical processes are also altered with disease and may occur before there is a change gross anatomy. PET is an imaging technique that is used to visualize some of these processes. The development of PET as we know it today began in 1974 with the development of a single ring detector system by Phelps et al. Today, over 350 PET scanners are in use in the world, mainly in the USA (over 140), Europe (particularly in the Anglo-Saxon countries and France) and Japan. Many of these facilities also have their own cyclotron to produce the positron emitters. In the Southern hemisphere, only Australia, Argentina. and recently Mexico, have a very small number of PET facilities. (Author)

  12. First PET Center in Mexico: the power of molecular imaging

    Energy Technology Data Exchange (ETDEWEB)

    Avila R, M.A. [Unidad PET, Facultad de Medicina, UNAM (Mexico)

    2001-09-01

    Positron Emission Tomography (PET) is a non-invasive diagnostic imaging technique modality. It represents the forefront of medical images and was developed as a quantitative technique for imaging biochemical and physiological processes in the human body. PET is unique because it produces images of the body's basic biochemistry or function. Traditional diagnostic techniques such as x-rays, CT scans or MRI, produce images of the body's anatomy or structure. The premise with these techniques is that the change in anatomy or structure that occurs with disease can be seen. However, biochemical processes are also altered with disease and may occur before there is a change gross anatomy. PET is an imaging technique that is used to visualize some of these processes. The development of PET as we know it today began in 1974 with the development of a single ring detector system by Phelps et al. Today, over 350 PET scanners are in use in the world, mainly in the USA (over 140), Europe (particularly in the Anglo-Saxon countries and France) and Japan. Many of these facilities also have their own cyclotron to produce the positron emitters. In the Southern hemisphere, only Australia, Argentina. and recently Mexico, have a very small number of PET facilities. (Author)

  13. Algebraic 2D PET image reconstruction using depth-of-interaction information

    International Nuclear Information System (INIS)

    Yamaya, Taiga; Obi, Takashi; Yamaguchi, Masahiro; Kita, Kouichi

    2001-01-01

    Recently a high-performance PET scanner, which measures depth-of-interaction (DOI) information, is being developed for molecular imaging. DOI measurement of multi-layered thin crystals can improve spatial resolution and scanner sensitivity simultaneously. In this paper, we apply an algebraic image reconstruction method to 2-dimensional (2D) DOI-PET scanners using accurate system modeling, in order to evaluate the effects of using DOI information on PET image quality. Algebraic image reconstruction methods have been successfully used to improve PET image quality, compared with the conventional filtered backprojection method. The proposed method is applied to simulated data for a small 2D DOI-PET scanner. The results show that accurate system modeling improves spatial resolution without noise emphasis, and that DOI information improves uniformity of spatial resolution. (author)

  14. Dual PET and Near-Infrared Fluorescence Imaging Probes as Tools for Imaging in Oncology

    Science.gov (United States)

    An, Fei-Fei; Chan, Mark; Kommidi, Harikrishna; Ting, Richard

    2016-01-01

    OBJECTIVE The purpose of this article is to summarize advances in PET fluorescence resolution, agent design, and preclinical imaging that make a growing case for clinical PET fluorescence imaging. CONCLUSION Existing SPECT, PET, fluorescence, and MRI contrast imaging techniques are already deeply integrated into the management of cancer, from initial diagnosis to the observation and management of metastases. Combined positron-emitting fluorescent contrast agents can convey new or substantial benefits that improve on these proven clinical contrast agents. PMID:27223168

  15. Quantitative imaging studies with PET VI. Project II

    International Nuclear Information System (INIS)

    Copper, M.; Chen, C.T.; Yasillo, N.; Gatley, J.; Ortega, C.; DeJesus, O.; Friedman, A.

    1985-01-01

    This project is focused upon the development of hardware and software to improve PET image analysis and upon clinical applications of PET. In this report the laboratory's progress in various attenuation correction methods for brain imaging are described. The use of time-of-flight information for image reconstruction is evaluated. The location of dopamine D1 and D2 receptors in brain was found to be largely in the basal ganghia. 1 tab. (DT)

  16. Clinical impact of 18F-FDG-PET/CT in the extra cardiac work-up of patients with infective endocarditis

    DEFF Research Database (Denmark)

    Asmar, Ali; Ozcan, Cengiz; Diederichsen, Axel C P

    2014-01-01

    OBJECTIVE: The purpose of this study was to assess the clinical importance of (18)F-FDG-PET/CT used in the extra cardiac work-up of patients with infective endocarditis (IE). BACKGROUND: IE is a serious condition with a significant mortality. Besides the degree of valvular involvement, the progno......OBJECTIVE: The purpose of this study was to assess the clinical importance of (18)F-FDG-PET/CT used in the extra cardiac work-up of patients with infective endocarditis (IE). BACKGROUND: IE is a serious condition with a significant mortality. Besides the degree of valvular involvement...

  17. Technique for producing cardiac radionuclide motion images

    International Nuclear Information System (INIS)

    Reese, I.C.; Mishkin, F.S.

    1975-01-01

    Sequential frames of different portions of the cardiac cycle are gated into a minicomputer by using an EKG signal recorded onto digital tape simultaneously with imaging information. Serial display of these frames on the computer oscilloscope or projection of 35-mm half frames of these images provides a cardiac motion image with information content adequate for qualitatively assessing cardiac motion. (U.S.)

  18. Automated movement correction for dynamic PET/CT images: evaluation with phantom and patient data.

    Science.gov (United States)

    Ye, Hu; Wong, Koon-Pong; Wardak, Mirwais; Dahlbom, Magnus; Kepe, Vladimir; Barrio, Jorge R; Nelson, Linda D; Small, Gary W; Huang, Sung-Cheng

    2014-01-01

    Head movement during a dynamic brain PET/CT imaging results in mismatch between CT and dynamic PET images. It can cause artifacts in CT-based attenuation corrected PET images, thus affecting both the qualitative and quantitative aspects of the dynamic PET images and the derived parametric images. In this study, we developed an automated retrospective image-based movement correction (MC) procedure. The MC method first registered the CT image to each dynamic PET frames, then re-reconstructed the PET frames with CT-based attenuation correction, and finally re-aligned all the PET frames to the same position. We evaluated the MC method's performance on the Hoffman phantom and dynamic FDDNP and FDG PET/CT images of patients with neurodegenerative disease or with poor compliance. Dynamic FDDNP PET/CT images (65 min) were obtained from 12 patients and dynamic FDG PET/CT images (60 min) were obtained from 6 patients. Logan analysis with cerebellum as the reference region was used to generate regional distribution volume ratio (DVR) for FDDNP scan before and after MC. For FDG studies, the image derived input function was used to generate parametric image of FDG uptake constant (Ki) before and after MC. Phantom study showed high accuracy of registration between PET and CT and improved PET images after MC. In patient study, head movement was observed in all subjects, especially in late PET frames with an average displacement of 6.92 mm. The z-direction translation (average maximum = 5.32 mm) and x-axis rotation (average maximum = 5.19 degrees) occurred most frequently. Image artifacts were significantly diminished after MC. There were significant differences (Pdynamic brain FDDNP and FDG PET/CT scans could improve the qualitative and quantitative aspects of images of both tracers.

  19. Image fusion between whole body FDG PET images and whole body MRI images using a full-automatic mutual information-based multimodality image registration software

    International Nuclear Information System (INIS)

    Uchida, Yoshitaka; Nakano, Yoshitada; Fujibuchi, Toshiou; Isobe, Tomoko; Kazama, Toshiki; Ito, Hisao

    2006-01-01

    We attempted image fusion between whole body PET and whole body MRI of thirty patients using a full-automatic mutual information (MI) -based multimodality image registration software and evaluated accuracy of this method and impact of the coregistrated imaging on diagnostic accuracy. For 25 of 30 fused images in body area, translating gaps were within 6 mm in all axes and rotating gaps were within 2 degrees around all axes. In head and neck area, considerably much gaps caused by difference of head inclination at imaging occurred in 16 patients, however these gaps were able to decrease by fused separately. In 6 patients, diagnostic accuracy using PET/MRI fused images was superior compared by PET image alone. This work shows that whole body FDG PET images and whole body MRI images can be automatically fused using MI-based multimodality image registration software accurately and this technique can add useful information when evaluating FDG PET images. (author)

  20. PET Imaging Stability Measurements During Simultaneous Pulsing of Aggressive MR Sequences on the SIGNA PET/MR System.

    Science.gov (United States)

    Deller, Timothy W; Khalighi, Mohammad Mehdi; Jansen, Floris P; Glover, Gary H

    2018-01-01

    The recent introduction of simultaneous whole-body PET/MR scanners has enabled new research taking advantage of the complementary information obtainable with PET and MRI. One such application is kinetic modeling, which requires high levels of PET quantitative stability. To accomplish the required PET stability levels, the PET subsystem must be sufficiently isolated from the effects of MR activity. Performance measurements have previously been published, demonstrating sufficient PET stability in the presence of MR pulsing for typical clinical use; however, PET stability during radiofrequency (RF)-intensive and gradient-intensive sequences has not previously been evaluated for a clinical whole-body scanner. In this work, PET stability of the GE SIGNA PET/MR was examined during simultaneous scanning of aggressive MR pulse sequences. Methods: PET performance tests were acquired with MR idle and during simultaneous MR pulsing. Recent system improvements mitigating RF interference and gain variation were used. A fast recovery fast spin echo MR sequence was selected for high RF power, and an echo planar imaging sequence was selected for its high heat-inducing gradients. Measurements were performed to determine PET stability under varying MR conditions using the following metrics: sensitivity, scatter fraction, contrast recovery, uniformity, count rate performance, and image quantitation. A final PET quantitative stability assessment for simultaneous PET scanning during functional MRI studies was performed with a spiral in-and-out gradient echo sequence. Results: Quantitation stability of a 68 Ge flood phantom was demonstrated within 0.34%. Normalized sensitivity was stable during simultaneous scanning within 0.3%. Scatter fraction measured with a 68 Ge line source in the scatter phantom was stable within the range of 40.4%-40.6%. Contrast recovery and uniformity were comparable for PET images acquired simultaneously with multiple MR conditions. Peak noise equivalent count

  1. Dynamic MR cardiac perfusion studies in patients with acquired heart diseases

    International Nuclear Information System (INIS)

    Finelli, D.A.; Adler, L.P.; Paschal, C.B.; Haacke, E.M.

    1990-01-01

    The combination of ultrafast scanning techniques with contrast administration has opened new venues for MR imaging relating to the physiology of organ perfusion. Regional cardiac perfusion determinations lend important additional information to the morphologic and functional data provided by conventional cardiac MR imaging. The authors of this paper studied 10 patients with acquired heart diseases, including ischemic heart disease, cardiomyopathy, ventricular hypertrophy, and cardiac tumor, using conventional spin-echo imaging, cine gradient-echo imaging, and dynamic Gd-DTPA--enhanced perfusion imaging with an ultrafast, inversion-recovery, Turbo-fast low-angle shot sequence. This technique enables analysis of the first pass and early biodistribution phases following contrast administration, information that has been correlated with cardiac catheterization, single photo emission CT (SPECT), and administration emission tomographic (PET) data

  2. The progress of PET based reporter gene imaging

    International Nuclear Information System (INIS)

    Zhao Wei; Zhang Xiuli

    2005-01-01

    More than two decades of intense research have allowed gene therapy to move from the laboratory to the clinical setting, where its use for the treatment of human pathologies has been considerably increased in the last years. However, many crucial questions remain to be solved in this challenging field. In vivo imaging with positron emission tomography (PET) by combination of the appropriate PET reporter gene and PET reporter probe could provide invaluable qualitative and quantitative information to answer multiple unsolved questions about gene therapy. PET imaging could be used to define parameters not available by other techniques that are of substantial interest not only for the proper understanding of the gene therapy process, but also for its future development and clinical application in humans. (authors)

  3. Cardiac tumours: non invasive detection and assessment by gated cardiac blood pool radionuclide imaging

    International Nuclear Information System (INIS)

    Pitcher, D.; Wainwright, R.; Brennand-Roper, D.; Deverall, P.; Sowton, E.; Maisey, M.

    1980-01-01

    Four patients with cardiac tumours were investigated by gated cardiac blood pool radionuclide imaging and echocardiography. Contrast angiocardiography was performed in three of the cases. Two left atrial tumours were detected by all three techniques. In one of these cases echocardiography alone showed additional mitral valve stenosis, but isotope imaging indicated tumour size more accurately. A large septal mass was detected by all three methods. In this patient echocardiography showed evidence of left ventricular outflow obstruction, confirmed at cardiac catheterisation, but gated isotope imaging provided a more detailed assessment of the abnormal cardiac anatomy. In the fourth case gated isotope imaging detected a large right ventricular tumour which had not been identified by echocardiography. Gated cardiac blood pool isotope imaging is a complementary technique to echocardiography for the non-invasive detection and assessment of cardiac tumours. (author)

  4. Metabolic imaging using PET

    International Nuclear Information System (INIS)

    Kudo, Takashi

    2007-01-01

    There is growing evidence that myocardial metabolism plays a key role not only in ischaemic heart disease but also in a variety of diseases which involve myocardium globally, such as heart failure and diabetes mellitus. Understanding myocardial metabolism in such diseases helps to elucidate the pathophysiology and assists in making therapeutic decisions. As well as providing information on regional changes, PET can deliver quantitative information about both regional and global changes in metabolism. This capability of quantitative measurement is one of the major advantages of PET along with physiological positron tracers, especially relevant in evaluating diseases which involve the whole myocardium. This review discusses major PET tracers for metabolic imaging and their clinical applications and contributions to research regarding ischaemic heart disease and other diseases such as heart failure and diabetic heart disease. Future applications of positron metabolic tracers for the detection of vulnerable plaque are also highlighted briefly. (orig.)

  5. PET CT imaging: the Philippine experience

    International Nuclear Information System (INIS)

    Santiago, Jonas Y.

    2011-01-01

    Currently, the most discussed fusion imaging is PET CT. Fusion technology has tremendous potential in diagnostic imaging to detect numerous conditions such as tumors, Alzheimer's disease, dementia and neural disorders. The fusion of PET with CT helps in the localization of molecular abnormalities, thereby increasing diagnostic accuracy and differentiating benign or artefact lesions from malignant diseases. It uses a radiotracer called fluro deoxyglucose that gives a clear distinction between pathological and physiological uptake. Interest in this technology is increasing and additional clinical validation are likely to induce more health care providers to invest in combined scanners. It is hope that in time, a better appreciation of its advantages over conventional and traditional imaging modalities will be realized. The first PET CT facility in the country was established at the St. Luke's Medical Center in Quezon City in 2008 and has since then provided a state-of-the art imaging modality to its patients here and those from other countries. The paper will present the experiences so far gained from its operation, including the measures and steps currently taken by the facility to ensure optimum workers and patient safety. Plans and programs to further enhance the awareness of the Filipino public on this advanced imaging modality for an improved health care delivery system may also be discussed briefly. (author)

  6. TH-E-202-01: Pitfalls and Remedies in PET/CT Imaging for RT Planning

    International Nuclear Information System (INIS)

    Pan, T.

    2016-01-01

    PET/CT is a very important imaging tool in the management of oncology patients. PET/CT has been applied for treatment planning and response evaluation in radiation therapy. This educational session will discuss: Pitfalls and remedies in PET/CT imaging for RT planning The use of hypoxia PET imaging for radiotherapy PET for tumor response evaluation The first presentation will address the issue of mis-registration between the CT and PET images in the thorax and the abdomen. We will discuss the challenges of respiratory gating and introduce an average CT technique to improve the registration for dose calculation and image-guidance in radiation therapy. The second presentation will discuss the use of hypoxia PET Imaging for radiation therapy. We will discuss various hypoxia radiotracers, the choice of clinical acquisition protocol (in particular a single late static acquisition versus a dynamic acquisition), and the compartmental modeling with different transfer rate constants explained. We will demonstrate applications of hypoxia imaging for dose escalation/de-escalation in clinical trials. The last presentation will discuss the use of PET/CT for tumor response evaluation. We will discuss anatomic response assessment vs. metabolic response assessment, visual evaluation and semi-quantitative evaluation, and limitations of current PET/CT assessment. We will summarize clinical trials using PET response in guiding adaptive radiotherapy. Finally, we will summarize recent advancements in PET/CT radiomics and non-FDG PET tracers for response assessment. Learning Objectives: Identify the causes of mis-registration of CT and PET images in PET/CT, and review the strategies to remedy the issue. Understand the basics of PET imaging of tumor hypoxia (radiotracers, how PET measures the hypoxia selective uptake, imaging protocols, applications in chemo-radiation therapy). Understand the basics of dynamic PET imaging, compartmental modeling and parametric images. Understand the

  7. TH-E-202-01: Pitfalls and Remedies in PET/CT Imaging for RT Planning

    Energy Technology Data Exchange (ETDEWEB)

    Pan, T. [UT MD Anderson Cancer Center (United States)

    2016-06-15

    PET/CT is a very important imaging tool in the management of oncology patients. PET/CT has been applied for treatment planning and response evaluation in radiation therapy. This educational session will discuss: Pitfalls and remedies in PET/CT imaging for RT planning The use of hypoxia PET imaging for radiotherapy PET for tumor response evaluation The first presentation will address the issue of mis-registration between the CT and PET images in the thorax and the abdomen. We will discuss the challenges of respiratory gating and introduce an average CT technique to improve the registration for dose calculation and image-guidance in radiation therapy. The second presentation will discuss the use of hypoxia PET Imaging for radiation therapy. We will discuss various hypoxia radiotracers, the choice of clinical acquisition protocol (in particular a single late static acquisition versus a dynamic acquisition), and the compartmental modeling with different transfer rate constants explained. We will demonstrate applications of hypoxia imaging for dose escalation/de-escalation in clinical trials. The last presentation will discuss the use of PET/CT for tumor response evaluation. We will discuss anatomic response assessment vs. metabolic response assessment, visual evaluation and semi-quantitative evaluation, and limitations of current PET/CT assessment. We will summarize clinical trials using PET response in guiding adaptive radiotherapy. Finally, we will summarize recent advancements in PET/CT radiomics and non-FDG PET tracers for response assessment. Learning Objectives: Identify the causes of mis-registration of CT and PET images in PET/CT, and review the strategies to remedy the issue. Understand the basics of PET imaging of tumor hypoxia (radiotracers, how PET measures the hypoxia selective uptake, imaging protocols, applications in chemo-radiation therapy). Understand the basics of dynamic PET imaging, compartmental modeling and parametric images. Understand the

  8. Applying Amide Proton Transfer MR Imaging to Hybrid Brain PET/MR: Concordance with Gadolinium Enhancement and Added Value to [18F]FDG PET.

    Science.gov (United States)

    Sun, Hongzan; Xin, Jun; Zhou, Jinyuan; Lu, Zaiming; Guo, Qiyong

    2018-06-01

    The purpose of this study is to evaluate the diagnostic concordance and metric correlations of amide proton transfer (APT) imaging with gadolinium-enhanced magnetic resonance imaging (MRI) and 2-deoxy-2-[ 18 F-]fluoro-D-glucose ([ 18 F]FDG) positron emission tomography (PET), using hybrid brain PET/MRI. Twenty-one subjects underwent brain gadolinium-enhanced [ 18 F]FDG PET/MRI prospectively. Imaging accuracy was compared between unenhanced MRI, MRI with enhancement, APT-weighted (APTW) images, and PET based on six diagnostic criteria. Among tumors, the McNemar test was further used for concordance assessment between gadolinium-enhanced imaging, APT imaging, and [ 18 F]FDG PET. As well, the relation of metrics between APT imaging and PET was analyzed by the Pearson correlation analysis. APT imaging and gadolinium-enhanced MRI showed superior and similar diagnostic accuracy. APTW signal intensity and gadolinium enhancement were concordant in 19 tumors (100 %), while high [ 18 F]FDG avidity was shown in only 12 (63.2 %). For the metrics from APT imaging and PET, there was significant correlation for 13 hypermetabolic tumors (P PET in the evaluation of tumor metabolic activity during brain PET/MR studies.

  9. Oncological applications of 18F-FDG PET imaging

    International Nuclear Information System (INIS)

    Li Lin

    2000-01-01

    Considering normal distribution of 18 F-FDG in human body, 18 F-FDG imaging using PET can be applied to brain tumors, colorectal cancer, lymphoma, melanoma, lung cancer and head and neck cancer. The author briefly focuses on application of 18 F-FDG PET imaging to breast cancer, pancreatic cancer, hepatocellular carcinoma, musculoskeletal neoplasms, endocrine neoplasms, genitourinary neoplasms, esophageal and gastric carcinomas

  10. ⁶⁸Ga-DOTA-TOC-PET/CT detects heart metastases from ileal neuroendocrine tumors.

    Science.gov (United States)

    Calissendorff, Jan; Sundin, Anders; Falhammar, Henrik

    2014-09-01

    Metastases from ileal neuroendocrine tumors (NETs) to the myocardium are rare and generally seen in patients with widespread metastatic NET disease. The objectives of this investigation were to describe the frequency of intracardiac metastases in ileal NET patients examined by (68)Ga-DOTA-TOC-PET/CT and to describe the cases in detail. All (68)Ga-DOTA-TOC-PET/CT examinations performed at the Karolinska University Hospital since 2010 until April 2012 were reviewed. In all, 128 out of 337 examinations were in patients with ileal NETs. Four patients had seven myocardiac metastases, yielding a frequency of 4.3 % in patients with ileal NETs. One patient had cardiac surgery while three were treated with somatostatin analogs. The cardiac metastases did not affect the patients' activity of daily life. (68)Ga-DOTA-TOC-PET/CT is an established imaging modality in identifying cardiac metastases in ileal NETs. Prospective studies are needed to confirm the true clinical value of (68)Ga-DOTA-TOC-PET/CT in detecting cardiac metastases in both ileal and non-ileal NETs.

  11. Non rigid respiratory motion correction in whole body PET/MR imaging

    International Nuclear Information System (INIS)

    Fayad, Hadi; Schmidt, Holger; Wuerslin, Christian; Visvikis, Dimitris

    2014-01-01

    Respiratory motion in PET/MR imaging leads to reduced quantitative and qualitative image accuracy. Correction methodologies include the use of respiratory synchronized gated frames which lead to low signal to noise ratio (SNR) given that each frame contains only part of the count available throughout an average PET acquisition. In this work, 4D MRI extracted elastic transformations were applied to list-mode data either inside the image reconstruction or to the reconstructed respiratory synchronized images to obtain respiration corrected PET images.

  12. The role of PET quantification in cardiovascular imaging.

    Science.gov (United States)

    Slomka, Piotr; Berman, Daniel S; Alexanderson, Erick; Germano, Guido

    2014-08-01

    Positron Emission Tomography (PET) has several clinical and research applications in cardiovascular imaging. Myocardial perfusion imaging with PET allows accurate global and regional measurements of myocardial perfusion, myocardial blood flow and function at stress and rest in one exam. Simultaneous assessment of function and perfusion by PET with quantitative software is currently the routine practice. Combination of ejection fraction reserve with perfusion information may improve the identification of severe disease. The myocardial viability can be estimated by quantitative comparison of fluorodeoxyglucose ( 18 FDG) and rest perfusion imaging. The myocardial blood flow and coronary flow reserve measurements are becoming routinely included in the clinical assessment due to enhanced dynamic imaging capabilities of the latest PET/CT scanners. Absolute flow measurements allow evaluation of the coronary microvascular dysfunction and provide additional prognostic and diagnostic information for coronary disease. Standard quantitative approaches to compute myocardial blood flow from kinetic PET data in automated and rapid fashion have been developed for 13 N-ammonia, 15 O-water and 82 Rb radiotracers. The agreement between software methods available for such analysis is excellent. Relative quantification of 82 Rb PET myocardial perfusion, based on comparisons to normal databases, demonstrates high performance for the detection of obstructive coronary disease. New tracers, such as 18 F-flurpiridaz may allow further improvements in the disease detection. Computerized analysis of perfusion at stress and rest reduces the variability of the assessment as compared to visual analysis. PET quantification can be enhanced by precise coregistration with CT angiography. In emerging clinical applications, the potential to identify vulnerable plaques by quantification of atherosclerotic plaque uptake of 18 FDG and 18 F-sodium fluoride tracers in carotids, aorta and coronary arteries

  13. Imaging with 124I in differentiated thyroid carcinoma: is PET/MRI superior to PET/CT?

    International Nuclear Information System (INIS)

    Binse, I.; Poeppel, T.D.; Ruhlmann, M.; Gomez, B.; Bockisch, A.; Rosenbaum-Krumme, S.J.; Umutlu, L.

    2016-01-01

    The aim of this study was to compare integrated PET/CT and PET/MRI for their usefulness in detecting and categorizing cervical iodine-positive lesions in patients with differentiated thyroid cancer using 124 I as tracer. The study group comprised 65 patients at high risk of iodine-positive metastasis who underwent PET/CT (low-dose CT scan, PET acquisition time 2 min; PET/CT 2 ) followed by PET/MRI of the neck 24 h after 124 I administration. PET images from both modalities were analysed for the numbers of tracer-positive lesions. Two different acquisition times were used for the comparisons, one matching the PET/CT 2 acquisition time (2 min, PET/MRI 2 ) and the other covering the whole MRI scan time (30 min, PET/MRI 30 ). Iodine-positive lesions were categorized as metastasis, thyroid remnant or inconclusive according to their location on the PET/CT images. Morphological information provided by MRI was considered for evaluation of lesions on PET/MRI and for volume information. PET/MRI 2 detected significantly more iodine-positive metastases and thyroid remnants than PET/CT 2 (72 vs. 60, p = 0.002, and 100 vs. 80, p = 0.001, respectively), but the numbers of patients with at least one tumour lesion identified were not significantly different (21/65 vs. 17/65 patients). PET/MRI 30 tended to detect more PET-positive metastases than PET/MRI 2 (88 vs. 72), but the difference was not significant (p = 0.07). Of 21 lesions classified as inconclusive on PET/CT, 5 were assigned to metastasis or thyroid remnant when evaluated by PET/MRI. Volume information was available in 34 % of iodine-positive metastases and 2 % of thyroid remnants on PET/MRI. PET/MRI of the neck was found to be superior to PET/CT in detecting iodine-positive lesions. This was attributed to the higher sensitivity of the PET component, Although helpful in some cases, we found no substantial advantage of PET/MRI over PET/CT in categorizing iodine-positive lesions as either metastasis or thyroid remnant

  14. Fusion of PET and MRI for Hybrid Imaging

    Science.gov (United States)

    Cho, Zang-Hee; Son, Young-Don; Kim, Young-Bo; Yoo, Seung-Schik

    Recently, the development of the fusion PET-MRI system has been actively studied to meet the increasing demand for integrated molecular and anatomical imaging. MRI can provide detailed anatomical information on the brain, such as the locations of gray and white matter, blood vessels, axonal tracts with high resolution, while PET can measure molecular and genetic information, such as glucose metabolism, neurotransmitter-neuroreceptor binding and affinity, protein-protein interactions, and gene trafficking among biological tissues. State-of-the-art MRI systems, such as the 7.0 T whole-body MRI, now can visualize super-fine structures including neuronal bundles in the pons, fine blood vessels (such as lenticulostriate arteries) without invasive contrast agents, in vivo hippocampal substructures, and substantia nigra with excellent image contrast. High-resolution PET, known as High-Resolution Research Tomograph (HRRT), is a brain-dedicated system capable of imaging minute changes of chemicals, such as neurotransmitters and -receptors, with high spatial resolution and sensitivity. The synergistic power of the two, i.e., ultra high-resolution anatomical information offered by a 7.0 T MRI system combined with the high-sensitivity molecular information offered by HRRT-PET, will significantly elevate the level of our current understanding of the human brain, one of the most delicate, complex, and mysterious biological organs. This chapter introduces MRI, PET, and PET-MRI fusion system, and its algorithms are discussed in detail.

  15. A 16-channel MR coil for simultaneous PET/MR imaging in breast cancer

    International Nuclear Information System (INIS)

    Dregely, Isabel; Lanz, Titus; Mueller, Matthias F.; Metz, Stephan; Kuschan, Marika; Nimbalkar, Manoj; Ziegler, Sibylle I.; Nekolla, Stephan G.; Schwaiger, Markus; Bundschuh, Ralph A.; Haase, Axel

    2015-01-01

    To implement and evaluate a dedicated receiver array coil for simultaneous positron emission tomography/magnetic resonance (PET/MR) imaging in breast cancer. A 16-channel receiver coil design was optimized for simultaneous PET/MR imaging. To assess MR performance, the signal-to-noise ratio, parallel imaging capability and image quality was evaluated in phantoms, volunteers and patients and compared to clinical standard protocols. For PET evaluation, quantitative 18 F-FDG PET images of phantoms and seven patients (14 lesions) were compared to images without the coil. In PET image reconstruction, a CT-based template of the coil was combined with the MR-acquired attenuation correction (AC) map of the phantom/patient. MR image quality was comparable to clinical MR-only examinations. PET evaluation in phantoms showed regionally varying underestimation of the standardised uptake value (SUV; mean 22 %) due to attenuation caused by the coil. This was improved by implementing the CT-based coil template in the AC (<2 % SUV underestimation). Patient data indicated that including the coil in the AC increased the SUV values in the lesions (21 ± 9 %). Using a dedicated PET/MR breast coil, state-of-the-art MRI was possible. In PET, accurate quantification and image homogeneity could be achieved if a CT-template of this coil was included in the AC for PET image reconstruction. (orig.)

  16. Impact of molecular imaging with PET on healthcare worldwide

    International Nuclear Information System (INIS)

    Alavi, Abbas

    2009-01-01

    Full text: FDG-PET imaging has substantially improved healthcare throughout the world. This technique has been applied to patients with some of the most serious diseases, including cancer, central nervous system disorders, cardiovascular disease and infections including infected prostheses. There is also enormous potential for further improvement in patient management using this technique, for example, in the detection of atherosclerosis and clots, and assessment of muscle function. Studies using FDG-PET methodology have led to the development of many novel radiotracers that have been designed to explore new diagnostic and therapeutic domains. We therefore expect that molecular imaging with PET will play an increasingly central role in research and in the optimal management of patients with many disorders. This will include diagnosing pathological processes at the molecular level and individualizing treatment for these patients. By utilizing PET and the appropriately labeled pharmaceuticals, one will be able to select the most suitable therapeutic drugs for a particular disease, instead of administering drugs to patients without a good idea of the chance of efficacy. Likewise, PET will increasingly play a major role in drug development by demonstrating the degree to which the intended pharmaceutical targets the diseased tissues in animal models and in human beings. PET will also assist in determining the rate of metabolism of the administered drugs by different tissues. PET imaging will also allow accurate staging of cancer and other serious diseases and will be adopted as the most accurate technique for monitoring response to treatment and detecting recurrence. The role of CT and/or MRI as independent modalities in medicine will decrease as the efficacy of PET is realized by scientists and clinicians alike. In particular, the use of contrast agents such as iodinated compounds and gadolinium based agents will be minimized. Similarly, imaging with single gamma

  17. Cardiac fluid dynamics meets deformation imaging.

    Science.gov (United States)

    Dal Ferro, Matteo; Stolfo, Davide; De Paris, Valerio; Lesizza, Pierluigi; Korcova, Renata; Collia, Dario; Tonti, Giovanni; Sinagra, Gianfranco; Pedrizzetti, Gianni

    2018-02-20

    Cardiac function is about creating and sustaining blood in motion. This is achieved through a proper sequence of myocardial deformation whose final goal is that of creating flow. Deformation imaging provided valuable contributions to understanding cardiac mechanics; more recently, several studies evidenced the existence of an intimate relationship between cardiac function and intra-ventricular fluid dynamics. This paper summarizes the recent advances in cardiac flow evaluations, highlighting its relationship with heart wall mechanics assessed through the newest techniques of deformation imaging and finally providing an opinion of the most promising clinical perspectives of this emerging field. It will be shown how fluid dynamics can integrate volumetric and deformation assessments to provide a further level of knowledge of cardiac mechanics.

  18. Current status and future perspective of PET

    International Nuclear Information System (INIS)

    Lee, Myung Chul

    2002-01-01

    Positron Emission Tomography (PET) is a nuclear medicine imaging modality that consists of systemic administration to a subject of a radiopharmaceutical labeled with a positron-emitting radionuclide. Following administration, its distribution in the organ or structure under study can be assessed as a function of time and space by (1) detecting the annihilation radiation resulting from the interaction of the positrons with matter, and (2) reconstructing the distribution of the radioactivity from a series of that used in computed tomography (CT). The nuclides most generally exhibit chemical properties that render them particularly desirable in physiological studies. The radionuclides most widely used in PET are F-18, C-11, O-15 and N-13. Regarding to the number of the current PET Centers worldwide (based on ICP data), more than 300 PET Centers were in operation in 2000. The use of PET technology grew rapidly compared to that in 1992 and 1996, particularly in the USA, which demonstrates a three-fold rise in PET installations. In 2001, 194 PET Centers were operating in the USA. In 1994, two clinical and research-oriented PET Centers at Seoul National University Hospital and Samsung Medical Center, was established as the first dedicated PET and Cyclotron machines in Korea, followed by two more PET facilities at the Korea Cancer Center Hospital, Ajou Medical Center, Yonsei University Medical Center, National Cancer Center and established their PET Center. Catholic Medical School and Pusan National University Hospital have finalized a plan to install PET machine in 2002, which results in total of nine PET Centers in Korea. Considering annual trends of PET application in four major PET centers in Korea in Asan Medical Center recent six years (from 1995 to 2000), a total of 11,564 patients have been studied every year and the number of PET studies has shown steep growth year upon year. We had, 1,020 PET patients in 1995. This number increased to 1,196, 1,756, 2,379, 3

  19. Cardiac magnetic resonance imaging

    African Journals Online (AJOL)

    2011-03-06

    Mar 6, 2011 ... Cardiac magnetic resonance imaging. Cardiovascular magnetic resonance imaging is becoming a routine diagnostic technique. BRUCE s sPOTTiswOOdE, PhD. MRC/UCT Medical Imaging Research Unit, University of Cape Town, and Division of Radiology, Stellenbosch University. Bruce Spottiswoode ...

  20. Attenuation correction for brain PET imaging using deep neural network based on dixon and ZTE MR images.

    Science.gov (United States)

    Gong, Kuang; Yang, Jaewon; Kim, Kyungsang; El Fakhri, Georges; Seo, Youngho; Li, Quanzheng

    2018-05-23

    Positron Emission Tomography (PET) is a functional imaging modality widely used in neuroscience studies. To obtain meaningful quantitative results from PET images, attenuation correction is necessary during image reconstruction. For PET/MR hybrid systems, PET attenuation is challenging as Magnetic Resonance (MR) images do not reflect attenuation coefficients directly. To address this issue, we present deep neural network methods to derive the continuous attenuation coefficients for brain PET imaging from MR images. With only Dixon MR images as the network input, the existing U-net structure was adopted and analysis using forty patient data sets shows it is superior than other Dixon based methods. When both Dixon and zero echo time (ZTE) images are available, we have proposed a modified U-net structure, named GroupU-net, to efficiently make use of both Dixon and ZTE information through group convolution modules when the network goes deeper. Quantitative analysis based on fourteen real patient data sets demonstrates that both network approaches can perform better than the standard methods, and the proposed network structure can further reduce the PET quantification error compared to the U-net structure. © 2018 Institute of Physics and Engineering in Medicine.

  1. Quantitative Evaluation of Atlas-based Attenuation Correction for Brain PET in an Integrated Time-of-Flight PET/MR Imaging System.

    Science.gov (United States)

    Yang, Jaewon; Jian, Yiqiang; Jenkins, Nathaniel; Behr, Spencer C; Hope, Thomas A; Larson, Peder E Z; Vigneron, Daniel; Seo, Youngho

    2017-07-01

    Purpose To assess the patient-dependent accuracy of atlas-based attenuation correction (ATAC) for brain positron emission tomography (PET) in an integrated time-of-flight (TOF) PET/magnetic resonance (MR) imaging system. Materials and Methods Thirty recruited patients provided informed consent in this institutional review board-approved study. All patients underwent whole-body fluorodeoxyglucose PET/computed tomography (CT) followed by TOF PET/MR imaging. With use of TOF PET data, PET images were reconstructed with four different attenuation correction (AC) methods: PET with patient CT-based AC (CTAC), PET with ATAC (air and bone from an atlas), PET with ATAC patientBone (air and tissue from the atlas with patient bone), and PET with ATAC boneless (air and tissue from the atlas without bone). For quantitative evaluation, PET mean activity concentration values were measured in 14 1-mL volumes of interest (VOIs) distributed throughout the brain and statistical significance was tested with a paired t test. Results The mean overall difference (±standard deviation) of PET with ATAC compared with PET with CTAC was -0.69 kBq/mL ± 0.60 (-4.0% ± 3.2) (P PET with ATAC boneless (-9.4% ± 3.7) was significantly worse than that of PET with ATAC (-4.0% ± 3.2) (P PET with ATAC patientBone (-1.5% ± 1.5) improved over that of PET with ATAC (-4.0% ± 3.2) (P PET/MR imaging achieves similar quantification accuracy to that from CTAC by means of atlas-based bone compensation. However, patient-specific anatomic differences from the atlas causes bone attenuation differences and misclassified sinuses, which result in patient-dependent performance variation of ATAC. © RSNA, 2017 Online supplemental material is available for this article.

  2. The diagnosis of anthracycline-induced cardiac damage and heart failure

    Directory of Open Access Journals (Sweden)

    Jarosław Dudka

    2009-05-01

    Full Text Available Routine examinations during chemotherapy containing anthracyclines evaluate heart function before treatment and monitor cardiotoxic effects during and after therapy. A number of methods are useful in cardiac assessment, including electrocardiography, radiology techniques (RTG, CT, MRI, PET-CT, PET-MRI, echocardiography, radioisotope imaging techniques (scyntygraphy, MUGA, PET, and ultra-structure evaluation in biopsy samples. Nevertheless, there is a continuous need for new methods to predict future damage at the initial stages of cardiac changes. In recent years the therapeutic usefulness of biochemical blood parameters in anthracycline-treated patients has been assessed. The levels of cardiac troponines (cTnI, cTnT, natriuretic peptides (ANP, BNP, and endothelin 1 have been included in the studies. Heart-type fatty acid binding protein (H-FABP is another promising factor showing cardiomyocytic impairment. However, the clinical use of biochemical parameters in diagnosing anthracycline-related cardiotoxicity is still a controversial issue.

  3. 64Cu-DOTA as a surrogate positron analog of Gd-DOTA for cardiac fibrosis detection with PET: pharmacokinetic study in a rat model of chronic MI.

    Science.gov (United States)

    Kim, Heejung; Lee, Sung-Jin; Davies-Venn, Cynthia; Kim, Jin Su; Yang, Bo Yeun; Yao, Zhengsheng; Kim, Insook; Paik, Chang H; Bluemke, David A

    2016-02-01

    The aim of this study was to investigate the pharmacokinetics of (64)Cu-DOTA (1,4,7,10-azacyclododecane-N,N',N'',N'''-tetraacetic acid), a positron surrogate analog of the late gadolinium (Gd)-enhancement cardiac magnetic resonance agent, Gd-DOTA, in a rat model of chronic myocardial infarction (MI) and its microdistribution in the cardiac fibrosis by autoradiography. DOTA was labeled with (64)Cu-acetate. CD rats (n=5) with MI by left anterior descending coronary artery ligation and normal rats (n=6) were injected intravenously with (64)Cu-DOTA (18.5 MBq, 0.02 mmol DOTA/kg). Dynamic PET imaging was performed for 60 min after injection. (18)F-Fluorodeoxyglucose ([(18)F]-FDG) PET imaging was performed to identify the viable myocardium. For the region of interest analysis, the (64)Cu-DOTA PET image was coregistered to the [(18)F]-FDG PET image. To validate the PET images, slices of heart samples from the base to the apex were analyzed using autoradiography and by histological staining with Masson's trichrome. (64)Cu-DOTA was rapidly taken up in the infarct area. The time-activity curves demonstrated that (64)Cu-DOTA concentrations in the blood, fibrotic tissue, and perfusion-rich organs peaked within a minute post injection; thereafter, it was rapidly washed out in parallel with blood clearance and excreted through the renal system. The blood clearance curve was biphasic, with a distribution half-life of less than 3 min and an elimination half-life of ∼21.8 min. The elimination half-life of (64)Cu-DOTA from the focal fibrotic tissue (∼22.4 min) and the remote myocardium (∼20.1 min) was similar to the blood elimination half-life. Consequently, the uptake ratios of focal fibrosis-to-blood and remote myocardium-to-blood remained stable for the time period between 10 and 60 min. The corresponding ratios obtained from images acquired from 30 to 60 min were 1.09 and 0.59, respectively, indicating that the concentration of (64)Cu-DOTA in the focal

  4. Patient motion effects on the quantification of regional myocardial blood flow with dynamic PET imaging.

    Science.gov (United States)

    Hunter, Chad R R N; Klein, Ran; Beanlands, Rob S; deKemp, Robert A

    2016-04-01

    Patient motion is a common problem during dynamic positron emission tomography (PET) scans for quantification of myocardial blood flow (MBF). The purpose of this study was to quantify the prevalence of body motion in a clinical setting and evaluate with realistic phantoms the effects of motion on blood flow quantification, including CT attenuation correction (CTAC) artifacts that result from PET-CT misalignment. A cohort of 236 sequential patients was analyzed for patient motion under resting and peak stress conditions by two independent observers. The presence of motion, affected time-frames, and direction of motion was recorded; discrepancy between observers was resolved by consensus review. Based on these results, patient body motion effects on MBF quantification were characterized using the digital NURBS-based cardiac-torso phantom, with characteristic time activity curves (TACs) assigned to the heart wall (myocardium) and blood regions. Simulated projection data were corrected for attenuation and reconstructed using filtered back-projection. All simulations were performed without noise added, and a single CT image was used for attenuation correction and aligned to the early- or late-frame PET images. In the patient cohort, mild motion of 0.5 ± 0.1 cm occurred in 24% and moderate motion of 1.0 ± 0.3 cm occurred in 38% of patients. Motion in the superior/inferior direction accounted for 45% of all detected motion, with 30% in the superior direction. Anterior/posterior motion was predominant (29%) in the posterior direction. Left/right motion occurred in 24% of cases, with similar proportions in the left and right directions. Computer simulation studies indicated that errors in MBF can approach 500% for scans with severe patient motion (up to 2 cm). The largest errors occurred when the heart wall was shifted left toward the adjacent lung region, resulting in a severe undercorrection for attenuation of the heart wall. Simulations also indicated that the

  5. Automatic delineation of brain regions on MRI and PET images from the pig

    DEFF Research Database (Denmark)

    Villadsen, Jonas; Hansen, Hanne D; Jørgensen, Louise M

    2018-01-01

    : Manual inter-modality spatial normalization to a MRI atlas is operator-dependent, time-consuming, and can be inaccurate with lack of cortical radiotracer binding or skull uptake. NEW METHOD: A parcellated PET template that allows for automatic spatial normalization to PET images of any radiotracer....... RESULTS: MRI and [11C]Cimbi-36 PET scans obtained in sixteen pigs made the basis for the atlas. The high resolution MRI scans allowed for creation of an accurately averaged MRI template. By aligning the within-subject PET scans to their MRI counterparts, an averaged PET template was created in the same...... the MRI template with individual MRI images and 0.92±0.26mm using the PET template with individual [11C]Cimbi-36 PET images. We tested the automatic procedure by assessing eleven PET radiotracers with different kinetics and spatial distributions by using perfusion-weighted images of early PET time frames...

  6. PET imaging in patients with Modic changes

    International Nuclear Information System (INIS)

    Albert, H.B.; Manniche, C.; Petersen, H.; Hoeilund-Carlsen, P.F.

    2009-01-01

    The aim of this study was via PET imaging to reveal if any highly metabolic processes were occurring in Modic changes type 1 and/or in the adjacent discs. Modic changes (MC) are signal changes in the vertebral endplate and body visualised by magnetic resonance imaging (MRI). MC are strongly associated with low back pain (LBP). MC type 1 appear to be inflammation on MRI, and histological and biochemical findings make it highly likely that an inflammation is present. Though MC is painful no known treatment is available, and it is unknown which entities affect the progress or regress of MC. The changes observed on MRI are slow and take months to develop, but faster changes in the metabolism might provide a platform for monitoring patients. Patients from The Back Centre Funen, with low back pain in the area of L1 to S1, MC type 1 in L1 to L5, and a previous herniated lumbar disc. All patients had a PET scan using FDG ( 18 F-fluorodeoxyglucose) as tracer. Included in the study were 11 patients, 4 women and 7 men, mean age 48.1 year (range 20-65). All MC were situated in the vertebrae both above and below the previously herniated disc/discs. Ten patients had MC at 1 level, and 1 had MC at 2 levels. The affected levels were 1 at L2/L3, 6 at L4 /L5, and 5 at L5/S1. All had a previous disc herniation and MC larger than 4 mm in diameter. Technically satisfactory PET scans were obtained. However, PET imaging showed no increases in metabolism in any vertebra or disc of any patient. Modic type 1 changes do not reveal themselves by showing increased metabolism with ordinary FDG PET imaging. PET tracers illuminating inflammation are being developed and hopefully may become more successful. (orig.)

  7. PET imaging in pediatric Hodgkin's lymphoma

    International Nuclear Information System (INIS)

    Hudson, M.M.; Krasin, M.J.; Kaste, S.C.

    2004-01-01

    Advances in diagnostic imaging technology, especially functional imaging modalities like positron emission tomography (PET), have significantly influenced the staging and treatment approaches used for pediatric Hodgkin's lymphoma. Today, the majority of children and adolescents diagnosed with Hodgkin's lymphoma will be cured following treatment with noncross-resistant combination chemotherapy alone or in combination with low-dose, involved-field radiation. This success produced a greater appreciation of long-term complications related to radiation, chemotherapy, and surgical staging that prompted significant changes in staging and treatment protocols for children and adolescents with Hodgkin's lymphoma. Contemporary treatment for pediatric Hodgkin's lymphoma uses a risk-adapted approach that reduces the number of combination chemotherapy cycles and radiation treatment fields and doses for patients with localized favorable disease presentation. Advances in diagnostic imaging technology have played a critical role in the development of these risk-adapted treatment regimens. The introduction of computed tomography (CT) provided an accurate and non-invasive modality to define nodal involvement below the diaphragm that motivated the change from surgical to clinical staging. The introduction of functional imaging modalities, like positron emission tomography (PET) scanning, provided the means to correlate tumor activity with anatomic features generated by CT and modify treatment based on tumor response. For centers with access to this modality, PET imaging plays an important role in staging, evaluating tumor response, planning radiation treatment fields, and monitoring after completion of therapy for pediatric Hodgkin's lymphoma. (orig.)

  8. Pharmacological experiment of 13N-ammonia as PET imaging agent

    International Nuclear Information System (INIS)

    Wang Mingfang; Tang Ganghua; Gao Xiao; Li Zhi; Wu Hubing; Huang Zuhan; Jiang Hong; Zhong Jinmei; Wang Quanshi

    2002-01-01

    Objective: To study the pharmacological characteristics of 13 N-ammonia, the clinical PET imaging methods of 13 N-ammonia, and its application in myocardial blood flow perfusion. Methods: The uptakes of 13 N-ammonia in the myocardium and other organs in dogs were measured by whole body scanning and chest dynamic PET scanning. The regional myocardial blood flow (rMBF) in healthy volunteers was also measured by the dynamic and static PET imaging following intravenous bolus administration of 13 N-ammonia. Results: The heart and lungs were the first-pass organs that was found out by PET imaging with 13 N-ammonia in dogs and human volunteers, the highest uptake of 13 N-ammonia in the myocardium was also observed. At 30 s after injection the radioactivity in the blood pool of left and right ventricles reached its peak, at 1 min it began to drop, and at 4-20 min after injection the lower radioactivity was kept on. Regional analysis of PET imaging showed that the myocardial uptake of 13 N-ammonia began at 10 s after injection, and the uptake in the septum wall was higher than that in the lateral wall; but in the septum wall was slightly higher than in the lateral wall at 2 min after injection. The radioactivity in the liver and lungs reached its peak at 30 s and was sharply declined hereafter. The uptake of 13 N-ammonia in the liver and lungs remained at the lower levels and the heart-to-blood, heart-to-liver and heart-to-lung ratios were above 2.0 after 5 min. Whole-body PET scanning for dogs showed that 13 N-ammonia was distributed primarily in the organs with rich blood flow and its clearance was observed in the kidney. The images of regional myocardial blood flow (rMBF) acquired from the dynamic or static PET imaging following intravenous bolus administration of 13 N-ammonia were of no difference. Conclusions: The analysis of distribution of 13 N-ammonia indicates that the heart-to-blood, heart-to-liver and heat-to-lung ratios were high and the PET images were clear

  9. Automatic delineation of brain regions on MRI and PET images from the pig.

    Science.gov (United States)

    Villadsen, Jonas; Hansen, Hanne D; Jørgensen, Louise M; Keller, Sune H; Andersen, Flemming L; Petersen, Ida N; Knudsen, Gitte M; Svarer, Claus

    2018-01-15

    The increasing use of the pig as a research model in neuroimaging requires standardized processing tools. For example, extraction of regional dynamic time series from brain PET images requires parcellation procedures that benefit from being automated. Manual inter-modality spatial normalization to a MRI atlas is operator-dependent, time-consuming, and can be inaccurate with lack of cortical radiotracer binding or skull uptake. A parcellated PET template that allows for automatic spatial normalization to PET images of any radiotracer. MRI and [ 11 C]Cimbi-36 PET scans obtained in sixteen pigs made the basis for the atlas. The high resolution MRI scans allowed for creation of an accurately averaged MRI template. By aligning the within-subject PET scans to their MRI counterparts, an averaged PET template was created in the same space. We developed an automatic procedure for spatial normalization of the averaged PET template to new PET images and hereby facilitated transfer of the atlas regional parcellation. Evaluation of the automatic spatial normalization procedure found the median voxel displacement to be 0.22±0.08mm using the MRI template with individual MRI images and 0.92±0.26mm using the PET template with individual [ 11 C]Cimbi-36 PET images. We tested the automatic procedure by assessing eleven PET radiotracers with different kinetics and spatial distributions by using perfusion-weighted images of early PET time frames. We here present an automatic procedure for accurate and reproducible spatial normalization and parcellation of pig PET images of any radiotracer with reasonable blood-brain barrier penetration. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Generation of structural MR images from amyloid PET: Application to MR-less quantification.

    Science.gov (United States)

    Choi, Hongyoon; Lee, Dong Soo

    2017-12-07

    Structural magnetic resonance (MR) images concomitantly acquired with PET images can provide crucial anatomical information for precise quantitative analysis. However, in the clinical setting, not all the subjects have corresponding MR. Here, we developed a model to generate structural MR images from amyloid PET using deep generative networks. We applied our model to quantification of cortical amyloid load without structural MR. Methods: We used florbetapir PET and structural MR data of Alzheimer's Disease Neuroimaging Initiative database. The generative network was trained to generate realistic structural MR images from florbetapir PET images. After the training, the model was applied to the quantification of cortical amyloid load. PET images were spatially normalized to the template space using the generated MR and then standardized uptake value ratio (SUVR) of the target regions was measured by predefined regions-of-interests. A real MR-based quantification was used as the gold standard to measure the accuracy of our approach. Other MR-less methods, a normal PET template-based, multi-atlas PET template-based and PET segmentation-based normalization/quantification methods, were also tested. We compared performance of quantification methods using generated MR with that of MR-based and MR-less quantification methods. Results: Generated MR images from florbetapir PET showed visually similar signal patterns to the real MR. The structural similarity index between real and generated MR was 0.91 ± 0.04. Mean absolute error of SUVR of cortical composite regions estimated by the generated MR-based method was 0.04±0.03, which was significantly smaller than other MR-less methods (0.29±0.12 for the normal PET-template, 0.12±0.07 for multiatlas PET-template and 0.08±0.06 for PET segmentation-based methods). Bland-Altman plots revealed that the generated MR-based SUVR quantification was the closest to the SUVR values estimated by the real MR-based method. Conclusion

  11. Technical considerations on scanning and image analysis for amyloid PET in dementia

    International Nuclear Information System (INIS)

    Akamatsu, Go; Ohnishi, Akihito; Aita, Kazuki; Ikari, Yasuhiko; Senda, Michio; Yamamoto, Yasuji

    2017-01-01

    Brain imaging techniques, such as computed tomography (CT), magnetic resonance imaging (MRI), single photon emission computed tomography (SPECT), and positron emission tomography (PET), can provide essential and objective information for the early and differential diagnosis of dementia. Amyloid PET is especially useful to evaluate the amyloid-β pathological process as a biomarker of Alzheimer's disease. This article reviews critical points about technical considerations on the scanning and image analysis methods for amyloid PET. Each amyloid PET agent has its own proper administration instructions and recommended uptake time, scan duration, and the method of image display and interpretation. In addition, we have introduced general scanning information, including subject positioning, reconstruction parameters, and quantitative and statistical image analysis. We believe that this article could make amyloid PET a more reliable tool in clinical study and practice. (author)

  12. Technical Considerations on Scanning and Image Analysis for Amyloid PET in Dementia.

    Science.gov (United States)

    Akamatsu, Go; Ohnishi, Akihito; Aita, Kazuki; Ikari, Yasuhiko; Yamamoto, Yasuji; Senda, Michio

    2017-01-01

    Brain imaging techniques, such as computed tomography (CT), magnetic resonance imaging (MRI), single photon emission computed tomography (SPECT), and positron emission tomography (PET), can provide essential and objective information for the early and differential diagnosis of dementia. Amyloid PET is especially useful to evaluate the amyloid-β pathological process as a biomarker of Alzheimer's disease. This article reviews critical points about technical considerations on the scanning and image analysis methods for amyloid PET. Each amyloid PET agent has its own proper administration instructions and recommended uptake time, scan duration, and the method of image display and interpretation. In addition, we have introduced general scanning information, including subject positioning, reconstruction parameters, and quantitative and statistical image analysis. We believe that this article could make amyloid PET a more reliable tool in clinical study and practice.

  13. Joint model of motion and anatomy for PET image reconstruction

    International Nuclear Information System (INIS)

    Qiao Feng; Pan Tinsu; Clark, John W. Jr.; Mawlawi, Osama

    2007-01-01

    Anatomy-based positron emission tomography (PET) image enhancement techniques have been shown to have the potential for improving PET image quality. However, these techniques assume an accurate alignment between the anatomical and the functional images, which is not always valid when imaging the chest due to respiratory motion. In this article, we present a joint model of both motion and anatomical information by integrating a motion-incorporated PET imaging system model with an anatomy-based maximum a posteriori image reconstruction algorithm. The mismatched anatomical information due to motion can thus be effectively utilized through this joint model. A computer simulation and a phantom study were conducted to assess the efficacy of the joint model, whereby motion and anatomical information were either modeled separately or combined. The reconstructed images in each case were compared to corresponding reference images obtained using a quadratic image prior based maximum a posteriori reconstruction algorithm for quantitative accuracy. Results of these studies indicated that while modeling anatomical information or motion alone improved the PET image quantitation accuracy, a larger improvement in accuracy was achieved when using the joint model. In the computer simulation study and using similar image noise levels, the improvement in quantitation accuracy compared to the reference images was 5.3% and 19.8% when using anatomical or motion information alone, respectively, and 35.5% when using the joint model. In the phantom study, these results were 5.6%, 5.8%, and 19.8%, respectively. These results suggest that motion compensation is important in order to effectively utilize anatomical information in chest imaging using PET. The joint motion-anatomy model presented in this paper provides a promising solution to this problem

  14. Feasibility of breathing-adapted PET/CT imaging for radiation therapy of Hodgkin lymphoma

    DEFF Research Database (Denmark)

    Aznar, M C; Andersen, Flemming; Berthelsen, A K

    2011-01-01

    Aim: Respiration can induce artifacts in positron emission tomography (PET)/computed tomography (CT) images leading to uncertainties in tumour volume, location and uptake quantification. Respiratory gating for PET images is now established but is not directly translatable to a radiotherapy setup....... in PET/CT images. These results suggest that advanced therapies (such as SUV-based dose painting) will likely require breathing-adapted PET images and that the relevant SUV thresholds are yet to be investigated....

  15. Imaging with {sup 124}I in differentiated thyroid carcinoma: is PET/MRI superior to PET/CT?

    Energy Technology Data Exchange (ETDEWEB)

    Binse, I.; Poeppel, T.D.; Ruhlmann, M.; Gomez, B.; Bockisch, A.; Rosenbaum-Krumme, S.J. [University of Duisburg-Essen, Medical Faculty, Department of Nuclear Medicine, Essen (Germany); Umutlu, L. [University of Duisburg-Essen, Medical Faculty, Department of Radiology, Essen (Germany)

    2016-06-15

    The aim of this study was to compare integrated PET/CT and PET/MRI for their usefulness in detecting and categorizing cervical iodine-positive lesions in patients with differentiated thyroid cancer using {sup 124}I as tracer. The study group comprised 65 patients at high risk of iodine-positive metastasis who underwent PET/CT (low-dose CT scan, PET acquisition time 2 min; PET/CT{sub 2}) followed by PET/MRI of the neck 24 h after {sup 124}I administration. PET images from both modalities were analysed for the numbers of tracer-positive lesions. Two different acquisition times were used for the comparisons, one matching the PET/CT{sub 2} acquisition time (2 min, PET/MRI{sub 2}) and the other covering the whole MRI scan time (30 min, PET/MRI{sub 30}). Iodine-positive lesions were categorized as metastasis, thyroid remnant or inconclusive according to their location on the PET/CT images. Morphological information provided by MRI was considered for evaluation of lesions on PET/MRI and for volume information. PET/MRI{sub 2} detected significantly more iodine-positive metastases and thyroid remnants than PET/CT{sub 2} (72 vs. 60, p = 0.002, and 100 vs. 80, p = 0.001, respectively), but the numbers of patients with at least one tumour lesion identified were not significantly different (21/65 vs. 17/65 patients). PET/MRI{sub 30} tended to detect more PET-positive metastases than PET/MRI{sub 2} (88 vs. 72), but the difference was not significant (p = 0.07). Of 21 lesions classified as inconclusive on PET/CT, 5 were assigned to metastasis or thyroid remnant when evaluated by PET/MRI. Volume information was available in 34 % of iodine-positive metastases and 2 % of thyroid remnants on PET/MRI. PET/MRI of the neck was found to be superior to PET/CT in detecting iodine-positive lesions. This was attributed to the higher sensitivity of the PET component, Although helpful in some cases, we found no substantial advantage of PET/MRI over PET/CT in categorizing iodine

  16. Kinetic modeling in PET imaging of hypoxia

    Science.gov (United States)

    Li, Fan; Joergensen, Jesper T; Hansen, Anders E; Kjaer, Andreas

    2014-01-01

    Tumor hypoxia is associated with increased therapeutic resistance leading to poor treatment outcome. Therefore the ability to detect and quantify intratumoral oxygenation could play an important role in future individual personalized treatment strategies. Positron Emission Tomography (PET) can be used for non-invasive mapping of tissue oxygenation in vivo and several hypoxia specific PET tracers have been developed. Evaluation of PET data in the clinic is commonly based on visual assessment together with semiquantitative measurements e.g. standard uptake value (SUV). However, dynamic PET contains additional valuable information on the temporal changes in tracer distribution. Kinetic modeling can be used to extract relevant pharmacokinetic parameters of tracer behavior in vivo that reflects relevant physiological processes. In this paper, we review the potential contribution of kinetic analysis for PET imaging of hypoxia. PMID:25250200

  17. Clinical advantages of three dimensional cine cardiac images

    International Nuclear Information System (INIS)

    Kinosada, Yasutomi; Okuda, Yasuyuki; Nakagawa, Tsuyoshi; Itou, Takafumi; Hattori, Takao.

    1996-01-01

    We evaluated clinical advantages and the quantitativeness of computerized three-dimensional (3D) cinematic images of a human heart, which were produced with a set of magnetic resonance (MR) images by using the computer graphic technique. Many contiguous, multi-location and multi-phase short axis images were obtained with the ECG gated conventional and fast cardiac imaging sequences in normal volunteers and selected patients with myocardial infarction, hypertrophic cardiomyopathy, dilated cardiomyopathy and left ventricular dysfunction. Judging by visual impressions of the computerized 3D cinematic cardiac images, we could easily understand and evaluate the myocardial motions or the anatomic and volumetric changes of a heart according to the cardiac phases. These images were especially useful to compare the wall motion, the left ventricular ejection-fraction (LVEF), or other cardiac functions and conditions between before and after therapeutic procedures such as percutaneous transluminal coronary angioplasty for patients with myocardial infarction. A good correlation between the LVEF calculated from a set of computerized 3D cinematic images and the ultra sound examinations were found. The results of our study showed that computerized 3D cinematic cardiac images were clinically useful to understand the myocardial motions qualitatively and to evaluate cardiac functions such as the LVEF quantitatively. (author)

  18. Regional quantitative analysis of cortical surface maps of FDG PET images

    CERN Document Server

    Protas, H D; Hayashi, K M; Chin Lung, Yu; Bergsneider, M; Sung Cheng, Huang

    2006-01-01

    Cortical surface maps are advantageous for visualizing the 3D profile of cortical gray matter development and atrophy, and for integrating structural and functional images. In addition, cortical surface maps for PET data, when analyzed in conjunction with structural MRI data allow us to investigate, and correct for, partial volume effects. Here we compared quantitative regional PET values based on a 3D cortical surface modeling approach with values obtained directly from the 3D FDG PET images in various atlas-defined regions of interest (ROIs; temporal, parietal, frontal, and occipital lobes). FDG PET and 3D MR (SPGR) images were obtained and aligned to ICBM space for 15 normal subjects. Each image was further elastically warped in 2D parameter space of the cortical surface, to align major cortical sulci. For each point within a 15 mm distance of the cortex, the value of the PET intensity was averaged to give a cortical surface map of FDG uptake. The average PET values on the cortical surface map were calcula...

  19. Automatic extraction of left ventricular mass and volumes using parametric images from non-ECG-gated 15O-water PET/CT

    DEFF Research Database (Denmark)

    Nordström, J; Harms, Hans; Lubberink, Mark

    of the present study was to investigate the feasibility of measuring LV geometry using dynamic 15O-water PET/CT without ECG-gating. Methods: Parametric images of MBF, perfusable tissue fraction (PTF) and LV blood pool were generated automatically using kinetic modelling. Segmentation of the LV wall using PTF......Introduction: 15O-water positron emission tomography (PET) is considered the gold standard for non-invasive quantification of myocardial blood flow (MBF). It has been shown to identify patients with significant coronary artery disease (CAD) with high accuracy. Hypertrophy with or without dilatation...... combined to measure stroke volume (SV=EDV-ESV) and ejection fraction (EF=SV/EDV). Accuracy was determined by comparing PET to cardiac magnetic resonance (CMR) in 30 asymptomatic patients with high grade LV regurgitation (group A). Precision was determined as inter-observer variation in group...

  20. ViRPET--combination of virtual reality and PET brain imaging

    Science.gov (United States)

    Majewski, Stanislaw; Brefczynski-Lewis, Julie

    2017-05-23

    Various methods, systems and apparatus are provided for brain imaging during virtual reality stimulation. In one example, among others, a system for virtual ambulatory environment brain imaging includes a mobile brain imager configured to obtain positron emission tomography (PET) scans of a subject in motion, and a virtual reality (VR) system configured to provide one or more stimuli to the subject during the PET scans. In another example, a method for virtual ambulatory environment brain imaging includes providing stimulation to a subject through a virtual reality (VR) system; and obtaining a positron emission tomography (PET) scan of the subject while moving in response to the stimulation from the VR system. The mobile brain imager can be positioned on the subject with an array of imaging photodetector modules distributed about the head of the subject.

  1. Feasibility of breathing-adapted PET/CT imaging for radiation therapy of Hodgkin lymphoma

    DEFF Research Database (Denmark)

    Aznar, M C; Andersen, Flemming; Berthelsen, A K

    2011-01-01

    Aim: Respiration can induce artifacts in positron emission tomography (PET)/computed tomography (CT) images leading to uncertainties in tumour volume, location and uptake quantification. Respiratory gating for PET images is now established but is not directly translatable to a radiotherapy setup....... uptake in PET/CT images. These results suggest that advanced therapies (such as SUV-based dose painting) will likely require breathing-adapted PET images and that the relevant SUV thresholds are yet to be investigated....

  2. Initial tests of a prototype MRI-compatible PET imager

    International Nuclear Information System (INIS)

    Raylman, Raymond R.; Majewski, Stan; Lemieux, Susan; Velan, S. Sendhil; Kross, Brain; Popov, Vladimir; Smith, Mark F.; Weisenberger, Andrew G.; Wojcik, Randy

    2006-01-01

    Multi-modality imaging is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET fused with anatomical structure images created by MRI, will allow the correlation of form with function. Our group (a collaboration of West Virginia University and Jefferson Lab) is developing a system to acquire MRI and PET images contemporaneously. The prototype device consists of two opposed detector heads, operating in coincidence mode with an active FOV of 5x5x4 cm 3 . Each MRI-PET detector module consists of an array of LSO detector elements (2.5x2.5x15 mm 3 ) coupled through a long fiber optic light guide to a single Hamamatsu flat panel PSPMT. The fiber optic light guide is made of a glued assembly of 2 mm diameter acrylic fibers with a total length of 2.5 m. The use of a light guides allows the PSPMTs to be positioned outside the bore of the 3 T General Electric MRI scanner used in the tests. Photon attenuation in the light guides resulted in an energy resolution of ∼60% FWHM, interaction of the magnetic field with PSPMT further reduced energy resolution to ∼85% FWHM. Despite this effect, excellent multi-plane PET and MRI images of a simple disk phantom were acquired simultaneously. Future work includes improved light guides, optimized magnetic shielding for the PSPMTs, construction of specialized coils to permit high-resolution MRI imaging, and use of the system to perform simultaneous PET and MRI or MR-spectroscopy

  3. Imaging of pancreatic tumors with PET

    International Nuclear Information System (INIS)

    Zanzi, I.; Robeson, W.; Vinciquerra, V.; Chaly, T.; Kroop, S.; Dahl, R.; Schulman, P.; Goldman, S.; Margouleff, D.

    1990-01-01

    This paper identifies pancreatic tumors with positron emission tomography (PET) using F-18 2-fluorodeoxyglucose (FDG). PET studies were performed in 13 patients with pancreatic tumors (11 adenocarcinomas; two islet cell tumors) using FDG. Data were acquired for 1 hour and in 14 contiguous 7-mm sections after attenuation correction. Suspicious areas were evaluated using quantitative techniques. In seven of 11 patients with adenocarcinomas, focal increase in FDG uptake correlated with pancreatic tumor shown on CT scans or MR images. Of the remaining four, one had a previous Whipple procedure, another had completed chemotherapy, and in two the tumor was out of the limited region imaged; in these four patients, liver metastases were identified in three

  4. Influence of PET/CT-introduction on PET scanning frequency and indications. Results of a multicenter study

    International Nuclear Information System (INIS)

    Stergar, H.; Bockisch, A.; Eschmann, S.M.; Krause, B.J.; Roedel, R.; Tiling, R.; Weckesser, M.

    2007-01-01

    Aim: to evaluate the influence of the introduction of combined PET/CT scanners into clinical routine. This investigation addresses the quantitative changes between PET/CT and stand alone PET. Methods: the study included all examinations performed on stand alone PET- or PET/CT-scanners within 12 month prior to and after implementation of PET/CT. The final data analysis included five university hospitals and a total number of 15 497 exams. We distinguished exams on stand alone tomographs prior to and after installation of the combined device as well as PET/CT scans particularly with regard to disease entities. Various further parameters were investigated. Results: the overall number of PET scans (PET and PET/CT) rose by 146% while the number of scans performed on stand alone scanners declined by 22%. Only one site registered an increase in stand alone PET. The number of exams for staging in oncology increased by 196% while that of cardiac scans decreased by 35% and the number of scans in neurology rose by 47%. The use of scans for radiotherapy planning increased to 7% of all PET/CT studies. The increase of procedures for so-called classic PET oncology indications was moderate compared to the more common tumors. An even greater increase was observed in some rare entities. Conclusions: the introduction of PET/CT led to more than a doubling of overall PET procedures with a main focus on oncology. Some of the observed changes in scanning frequency may be caused by a rising availability of new radiotracers and advancements of competing imaging methods. Nevertheless the evident increase in the use of PET/CT for the most common tumour types demonstrates its expanding role in cancer staging. The combination of molecular and morphologic imaging has not only found its place but is still gaining greater importance with new developments in technology and radiochemistry. (orig.)

  5. Evaluation of cardiac involvement using radionuclide myuocardial imaging in patients with Takayasu arteritis

    International Nuclear Information System (INIS)

    Yang Minfu; Guo Xinhua; He Zuoxiang; Jiang Xiongjing; Dou Kefei

    2008-01-01

    Objective: The aim of the study was to assess the value of radionuclide myocardial imaging in the evaluation of cardiac involvement in patients with Takayasu arteritis (TA). Methods: The 99 Tc m -methoxyisobutylisonitrile myocardial perlusion imaging (MIBI-MPI) and (or) 18 F-fluorodeoxyglucose (FDG) PET imaging findings in 12 TA patients [3 men and 9 women, mean age (35 ± 15) years] with coronary lesions (CL; n=8) or aortic insufficiency (AI; n=4) were retrospectively reviewed and analysed. Of the 4 AI-TA patients, 1 underwent exercise MIBI-MPI, 1 underwent pharmacologic stress MIBI-MPI and 2 un- derwent resting MIBI-MPI. Of the 8 CL-TA patients, 4 pnderwent MIBI-MPI (2 stress and 2 rest) and 4 un- derwent a dual-isotope simultaneous acquisition (DISA) SPECT protocol after injection of MIBI and FDG. Results: All 4 AI-TA patients showed left ventricular enlargement but no peffusion abnormalities. In 3 CL- TA patients with no documented infarct, MPI or DISA showed stress ischemia (n=2) or mismatched perfusion-metabolism defects (n=1). In the remaining 5 CL-TA patients with documented infarcts, 2 showed large perfusion defects on resting MIBI and 3 showed matched perfusion-metabolism defects on DISA SPECT. Conclusion: Radionuclide imaging is useful in providing a comprehensive functional evaluation for TA patients with cardiac involvement. (authors)

  6. Image artifacts from MR-based attenuation correction in clinical, whole-body PET/MRI

    DEFF Research Database (Denmark)

    Keller, Sune H; Holm, Søren; Hansen, Adam E

    2013-01-01

    Integrated whole-body PET/MRI tomographs have become available. PET/MR imaging has the potential to supplement, or even replace combined PET/CT imaging in selected clinical indications. However, this is true only if methodological pitfalls and image artifacts arising from novel MR-based attenuation...

  7. FDG PET/CT imaging as a biomarker in lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Meignan, Michel; Itti, Emmanuel [Hopitaux Universitaires Henri Mondor, Paris-Est Creteil University, LYSA Imaging, Department of Nuclear Medicine, Creteil (France); Gallamini, Andrea [Nice University, Research, Innovation and Statistic Department, Antoine Lacassagne Cancer Center, Nice (France); Scientific Research Committee, S. Croce Hospital, Cuneo (Italy); Younes, Anas [Memorial Sloan Kettering Cancer Center, Lymphoma Service, New York, NY (United States)

    2015-04-01

    FDG PET/CT has changed the management of FDG-avid lymphoma and is now recommended as the imaging technique of choice for staging and restaging. The need for tailoring therapy to reduce toxicity in patients with a favourable outcome and for improving treatment in those with high-risk factors requires accurate diagnostic methods and a new prognostic algorithm to identify different risk categories. New drugs are used in relapsed/refractory patients. The role of FDG PET/CT as a biomarker in this context is summarized in this review. New trends in FDG metabolic imaging in lymphoma are addressed including metabolic tumour volume measurement at staging and integrative PET which combines PET data with clinical and molecular markers or other imaging techniques. The quantitative approach for response assessment which is under investigation and is used in large ongoing trials is compared with visual criteria. The place of FDG in the era of targeted therapy is discussed. (orig.)

  8. The Role of 18F-FDG PET/CT Integrated Imaging in Distinguishing Malignant from Benign Pleural Effusion

    Science.gov (United States)

    Sun, Yajuan; Yu, Hongjuan; Ma, Jingquan

    2016-01-01

    Objective The aim of our study was to evaluate the role of 18F-FDG PET/CT integrated imaging in differentiating malignant from benign pleural effusion. Methods A total of 176 patients with pleural effusion who underwent 18F-FDG PET/CT examination to differentiate malignancy from benignancy were retrospectively researched. The images of CT imaging, 18F-FDG PET imaging and 18F-FDG PET/CT integrated imaging were visually analyzed. The suspected malignant effusion was characterized by the presence of nodular or irregular pleural thickening on CT imaging. Whereas on PET imaging, pleural 18F-FDG uptake higher than mediastinal activity was interpreted as malignant effusion. Images of 18F-FDG PET/CT integrated imaging were interpreted by combining the morphologic feature of pleura on CT imaging with the degree and form of pleural 18F-FDG uptake on PET imaging. Results One hundred and eight patients had malignant effusion, including 86 with pleural metastasis and 22 with pleural mesothelioma, whereas 68 patients had benign effusion. The sensitivities of CT imaging, 18F-FDG PET imaging and 18F-FDG PET/CT integrated imaging in detecting malignant effusion were 75.0%, 91.7% and 93.5%, respectively, which were 69.8%, 91.9% and 93.0% in distinguishing metastatic effusion. The sensitivity of 18F-FDG PET/CT integrated imaging in detecting malignant effusion was higher than that of CT imaging (p = 0.000). For metastatic effusion, 18F-FDG PET imaging had higher sensitivity (p = 0.000) and better diagnostic consistency with 18F-FDG PET/CT integrated imaging compared with CT imaging (Kappa = 0.917 and Kappa = 0.295, respectively). The specificities of CT imaging, 18F-FDG PET imaging and 18F-FDG PET/CT integrated imaging were 94.1%, 63.2% and 92.6% in detecting benign effusion. The specificities of CT imaging and 18F-FDG PET/CT integrated imaging were higher than that of 18F-FDG PET imaging (p = 0.000 and p = 0.000, respectively), and CT imaging had better diagnostic consistency with

  9. The Role of 18F-FDG PET/CT Integrated Imaging in Distinguishing Malignant from Benign Pleural Effusion.

    Science.gov (United States)

    Sun, Yajuan; Yu, Hongjuan; Ma, Jingquan; Lu, Peiou

    2016-01-01

    The aim of our study was to evaluate the role of 18F-FDG PET/CT integrated imaging in differentiating malignant from benign pleural effusion. A total of 176 patients with pleural effusion who underwent 18F-FDG PET/CT examination to differentiate malignancy from benignancy were retrospectively researched. The images of CT imaging, 18F-FDG PET imaging and 18F-FDG PET/CT integrated imaging were visually analyzed. The suspected malignant effusion was characterized by the presence of nodular or irregular pleural thickening on CT imaging. Whereas on PET imaging, pleural 18F-FDG uptake higher than mediastinal activity was interpreted as malignant effusion. Images of 18F-FDG PET/CT integrated imaging were interpreted by combining the morphologic feature of pleura on CT imaging with the degree and form of pleural 18F-FDG uptake on PET imaging. One hundred and eight patients had malignant effusion, including 86 with pleural metastasis and 22 with pleural mesothelioma, whereas 68 patients had benign effusion. The sensitivities of CT imaging, 18F-FDG PET imaging and 18F-FDG PET/CT integrated imaging in detecting malignant effusion were 75.0%, 91.7% and 93.5%, respectively, which were 69.8%, 91.9% and 93.0% in distinguishing metastatic effusion. The sensitivity of 18F-FDG PET/CT integrated imaging in detecting malignant effusion was higher than that of CT imaging (p = 0.000). For metastatic effusion, 18F-FDG PET imaging had higher sensitivity (p = 0.000) and better diagnostic consistency with 18F-FDG PET/CT integrated imaging compared with CT imaging (Kappa = 0.917 and Kappa = 0.295, respectively). The specificities of CT imaging, 18F-FDG PET imaging and 18F-FDG PET/CT integrated imaging were 94.1%, 63.2% and 92.6% in detecting benign effusion. The specificities of CT imaging and 18F-FDG PET/CT integrated imaging were higher than that of 18F-FDG PET imaging (p = 0.000 and p = 0.000, respectively), and CT imaging had better diagnostic consistency with 18F-FDG PET/CT integrated

  10. Multi-layer cube sampling for liver boundary detection in PET-CT images.

    Science.gov (United States)

    Liu, Xinxin; Yang, Jian; Song, Shuang; Song, Hong; Ai, Danni; Zhu, Jianjun; Jiang, Yurong; Wang, Yongtian

    2018-06-01

    Liver metabolic information is considered as a crucial diagnostic marker for the diagnosis of fever of unknown origin, and liver recognition is the basis of automatic diagnosis of metabolic information extraction. However, the poor quality of PET and CT images is a challenge for information extraction and target recognition in PET-CT images. The existing detection method cannot meet the requirement of liver recognition in PET-CT images, which is the key problem in the big data analysis of PET-CT images. A novel texture feature descriptor called multi-layer cube sampling (MLCS) is developed for liver boundary detection in low-dose CT and PET images. The cube sampling feature is proposed for extracting more texture information, which uses a bi-centric voxel strategy. Neighbour voxels are divided into three regions by the centre voxel and the reference voxel in the histogram, and the voxel distribution information is statistically classified as texture feature. Multi-layer texture features are also used to improve the ability and adaptability of target recognition in volume data. The proposed feature is tested on the PET and CT images for liver boundary detection. For the liver in the volume data, mean detection rate (DR) and mean error rate (ER) reached 95.15 and 7.81% in low-quality PET images, and 83.10 and 21.08% in low-contrast CT images. The experimental results demonstrated that the proposed method is effective and robust for liver boundary detection.

  11. Simultaneous functional imaging using fPET and fMRI

    Energy Technology Data Exchange (ETDEWEB)

    Villien, Marjorie [CERMEP (France)

    2015-05-18

    Brain mapping of task-associated changes in metabolism with PET has been accomplished by subtracting scans acquired during two distinct static states. We have demonstrated that PET can provide truly dynamic information on cerebral energy metabolism using constant infusion of FDG and multiple stimuli in a single experiment. We demonstrate here that the functional PET (fPET-FDG) method accomplished simultaneously with fMRI, can enable the first direct comparisons in time, space and magnitude of hemodynamics and oxygen and glucose consumption. The imaging studies were performed on a 3T Tim-Trio MR scanner modified to support an MR-compatible BrainPET insert. Ten healthy subjects were included. The total PET acquisition and infusion time was 90 minutes. We did 3 blocks of right hand fingers tapping for 10 minutes at 30, 50 and 70 minutes after the beginning of the PET acquisition. ASL and BOLD imaging were acquired simultaneously during the motor paradigm. Changes in glucose utilization are easily observed as changes in the TAC slope of the PET data (FDG utilization rate) and in the derivative signal during motor stimuli in the activated voxels. PET and MRI (ASL, and BOLD) activations are largely colocalized but with very different statistical significance and temporal dynamic, especially in the ipsilateral side of the stimuli. This study demonstrated that motor activation can be measured dynamically during a single FDG PET scan. The complementary nature of fPET-FDG to fMRI capitalizes on the emerging technology of hybrid MR-PET scanners. fPET-FDG, combined with quantitative fMRI methods, allow us to simultaneously measure dynamic changes in glucose utilization and hemodynamic, addressing vital questions about neurovascular coupling.

  12. Simultaneous functional imaging using fPET and fMRI

    International Nuclear Information System (INIS)

    Villien, Marjorie

    2015-01-01

    Brain mapping of task-associated changes in metabolism with PET has been accomplished by subtracting scans acquired during two distinct static states. We have demonstrated that PET can provide truly dynamic information on cerebral energy metabolism using constant infusion of FDG and multiple stimuli in a single experiment. We demonstrate here that the functional PET (fPET-FDG) method accomplished simultaneously with fMRI, can enable the first direct comparisons in time, space and magnitude of hemodynamics and oxygen and glucose consumption. The imaging studies were performed on a 3T Tim-Trio MR scanner modified to support an MR-compatible BrainPET insert. Ten healthy subjects were included. The total PET acquisition and infusion time was 90 minutes. We did 3 blocks of right hand fingers tapping for 10 minutes at 30, 50 and 70 minutes after the beginning of the PET acquisition. ASL and BOLD imaging were acquired simultaneously during the motor paradigm. Changes in glucose utilization are easily observed as changes in the TAC slope of the PET data (FDG utilization rate) and in the derivative signal during motor stimuli in the activated voxels. PET and MRI (ASL, and BOLD) activations are largely colocalized but with very different statistical significance and temporal dynamic, especially in the ipsilateral side of the stimuli. This study demonstrated that motor activation can be measured dynamically during a single FDG PET scan. The complementary nature of fPET-FDG to fMRI capitalizes on the emerging technology of hybrid MR-PET scanners. fPET-FDG, combined with quantitative fMRI methods, allow us to simultaneously measure dynamic changes in glucose utilization and hemodynamic, addressing vital questions about neurovascular coupling.

  13. 18F-FDOPA PET/CT imaging of insulinoma revisited

    International Nuclear Information System (INIS)

    Imperiale, Alessio; Namer, Izzie-Jacques; Sebag, Frederic; Vix, Michel; Castinetti, Frederic; Kessler, Laurence; Moreau, Francois; Bachellier, Philippe; Guillet, Benjamin; Mundler, Olivier; Taieb, David

    2015-01-01

    18 F-FDOPA PET imaging is increasingly used in the work-up of patients with neuroendocrine tumours. It has been shown to be of limited value in localizing pancreatic insulin-secreting tumours in adults with hyperinsulinaemic hypoglycaemia (HH) mainly due to 18 F-FDOPA uptake by the whole pancreatic gland. The objective of this study was to review our experience with 18 F-FDOPA PET/CT imaging with carbidopa (CD) premedication in patients with HH in comparison with PET/CT studies performed without CD premedication in an independent population. A retrospective study including 16 HH patients who were investigated between January 2011 and December 2013 using 18 F-FDOPA PET/CT (17 examinations) in two academic endocrine tumour centres was conducted. All PET/CT examinations were performed under CD premedication (200 mg orally, 1 - 2 h prior to tracer injection). The PET/CT acquisition protocol included an early acquisition (5 min after 18 F-FDOPA injection) centred over the upper abdomen and a delayed whole-body acquisition starting 20 - 30 min later. An independent series of eight consecutive patients with HH and investigated before 2011 were considered for comparison. All patients had a reference whole-body PET/CT scan performed about 1 h after 18 F-FDOPA injection. In all cases, PET/CT was performed without CD premedication. In the study group, 18 F-FDOPA PET/CT with CD premedication was positive in 8 out of 11 patients with histologically proven insulinoma (73 %). All 18 F-FDOPA PET/CT-avid insulinomas were detected on early images and 5 of 11 (45 %) on delayed ones. The tumour/normal pancreas uptake ratio was not significantly different between early and delayed acquisitions. Considering all patients with HH, including those without imaging evidence of disease, the detection rate of the primary lesions using CD-assisted 18 F-FDOPA PET/CT was 53 %, showing 9 insulinomas in 17 studies performed. In the control group (without CD premedication, eight patients), the final

  14. Combined FDG PET/CT imaging for restaging of colorectal cancer patients: impact of image fusion on staging accuracy

    International Nuclear Information System (INIS)

    Strunk, H.; Jaeger, U.; Flacke, S.; Hortling, N.; Bucerius, J.; Joe, A.; Reinhardt, M.; Palmedo, H.

    2005-01-01

    Purpose: To evaluate the diagnostic impact of positron emission tomography (PET) with fluorine-18-labeled deoxy-D-glucose (FDG) combined with non-contrast computed tomography (CT) as PET-CT modality in restaging colorectal cancer patients. Material and methods: In this retrospective study, 29 consecutive patients with histologically proven colorectal cancer (17 female, 12 male, aged 51-76 years) underwent whole body scans in one session on a dual modality PET-CT system (Siemens Biograph) 90 min. after i.v. administration of 370 MBq 18 F-FDG. The CT imaging was performed with 40 mAs, 130 kV, slice-thickness 5 mm and without i.v. contrast administration. PET and CT images were reconstructed with a slice-thickness of 5 mm in coronal, sagittal and transverse planes. During a first step of analysis, PET and CT images were scored blinded and independently by a group of two nuclear medicine physicians and a group of two radiologists, respectively. For this purpose, a five-point-scale was used. The second step of data-analysis consisted of a consensus reading by both groups. During the consensus reading, first a virtual (meaning mental) fusion of PET and CT images and afterwards the 'real' fusion (meaning coregistered) PET-CT images were also scored with the same scale. The imaging results were compared with histopathology findings and the course of disease during further follow-up. Results: The total number of malignant lesions detected with the combined PET/CT were 86. For FDG-PET alone it was n=68, and for CT alone n=65. Comparing PET-CT and PET, concordance was found in 81 of 104 lesions. Discrepancies predominantly occurred in the lung, where PET alone often showed true positive results in lymph nodes and soft tissue masses, where CT often was false negative. Comparing mental fusion and 'real' co-registered images, concordance was found in 94 of 104 lesions. In 13 lesions or, respectively, in 7 of 29 patients, a relevant information was gathered using fused images

  15. [F-18]FDG imaging of head and neck tumors: comparison of hybrid PET, dedicated PET and CT

    International Nuclear Information System (INIS)

    Dresel, S.; Brinkbaeumer, K.; Schmid, R.; Poepperl, G.; Hahn, K.; Szeimies, U.

    2001-01-01

    Aim: Aim of the study was to evaluate [F-18]FDG imaging of head and neck tumors using a Hybrid-PET device of the 2nd or 3rd generation. Examinations were compared to dedicated PET and Spiral-CT. Methods: 54 patients suffering from head and neck tumors were examined using dedicated PET and Hybrid-PET after injection of 185-350 MBq [F-18]FDG. Examinations were carried out on the dedicated PET first followed by a scan on the Hybrid-PET. Dedicated PET was acquired in 3D mode, Hybrid-PET was performed in list mode using an axial filter. Reconstruction of data was performed iteratively on both, dedicated PET and Hybrid-PET. All patients received a CT scan in multislice technique. All finding have been verified by the goldstandard histology or in case of negative histology by follow up. Results: Using dedicated PET the primary or recurrent lesion was correctly diagnosed in 47/48 patients, using Hybrid-PET in 46/48 patients and using CT in 25/48 patients. Metastatic disease in cervical lymph nodes was diagnosed in 17/18 patients with dedicated PET, in 16/18 patients with Hybrid-PET and in 15/18 with CT. False positive results with regard to lymph node metastasis were seen with one patient for dedicated PET and Hybrid-PET, respectively, and with 18 patients for CT. In a total of 11 patients unknown metastastic lesions were seen with dedicated PET and with Hybrid-PET elsewhere in the body. Additional malignant disease other than the head and neck tumor was found in 4 patients. Conclusion: Using Hybrid-PET for [F-18]FDG imaging reveals a loss of sensitivity and specificity of about 1-5% as compared to dedicated PET in head and neck tumors. [F-18]FDG PET with both, dedicated PET and Hybrid-PET is superior to CT in the diagnosis of primary or recurrent lesions as well as in the assessment of lymph node involvement. (orig.) [de

  16. Fluorine-18 NaF PET imaging of child abuse

    Energy Technology Data Exchange (ETDEWEB)

    Drubach, Laura A. [Children' s Hospital Boston and Harvard Medical School, Department of Radiology, Division of Nuclear Medicine/PET, Boston, MA (United States); Sapp, Mark.V. [School of Osteopathic Medicine, Child Abuse Research Education and Services (CARES) Institute University of Medicine and Dentistry of New Jersey, New Jersey (United States); Laffin, Stephen [Children' s Hospital Boston, Department of Radiology, Division of Nuclear Medicine/PET, Boston, MA (United States); Kleinman, Paul K. [Children' s Hospital Boston and Harvard Medical School, Department of Radiology, Division of Musculoskeletal Imaging, Boston, MA (United States)

    2008-07-15

    We describe the use of {sup 18}F-NaF positron emission tomography (PET) whole-body imaging for the evaluation of skeletal trauma in a case of suspected child abuse. To our knowledge, 18F NaF PET has not been used in the past for the evaluation of child abuse. In our patient, this technique detected all sites of trauma shown by initial and follow-up skeletal surveys, including bilateral metaphyseal fractures of the proximal humeri. Fluorine-18 NaF PET has potential advantage over Tc-99m-labeled methylene diphosphonate (MDP) based upon superior image contrast and spatial resolution. (orig.)

  17. Fluorine-18 NaF PET imaging of child abuse

    International Nuclear Information System (INIS)

    Drubach, Laura A.; Sapp, Mark V.; Laffin, Stephen; Kleinman, Paul K.

    2008-01-01

    We describe the use of 18 F-NaF positron emission tomography (PET) whole-body imaging for the evaluation of skeletal trauma in a case of suspected child abuse. To our knowledge, 18F NaF PET has not been used in the past for the evaluation of child abuse. In our patient, this technique detected all sites of trauma shown by initial and follow-up skeletal surveys, including bilateral metaphyseal fractures of the proximal humeri. Fluorine-18 NaF PET has potential advantage over Tc-99m-labeled methylene diphosphonate (MDP) based upon superior image contrast and spatial resolution. (orig.)

  18. Model-based image reconstruction for four-dimensional PET

    International Nuclear Information System (INIS)

    Li Tianfang; Thorndyke, Brian; Schreibmann, Eduard; Yang Yong; Xing Lei

    2006-01-01

    Positron emission tonography (PET) is useful in diagnosis and radiation treatment planning for a variety of cancers. For patients with cancers in thoracic or upper abdominal region, the respiratory motion produces large distortions in the tumor shape and size, affecting the accuracy in both diagnosis and treatment. Four-dimensional (4D) (gated) PET aims to reduce the motion artifacts and to provide accurate measurement of the tumor volume and the tracer concentration. A major issue in 4D PET is the lack of statistics. Since the collected photons are divided into several frames in the 4D PET scan, the quality of each reconstructed frame degrades as the number of frames increases. The increased noise in each frame heavily degrades the quantitative accuracy of the PET imaging. In this work, we propose a method to enhance the performance of 4D PET by developing a new technique of 4D PET reconstruction with incorporation of an organ motion model derived from 4D-CT images. The method is based on the well-known maximum-likelihood expectation-maximization (ML-EM) algorithm. During the processes of forward- and backward-projection in the ML-EM iterations, all projection data acquired at different phases are combined together to update the emission map with the aid of deformable model, the statistics is therefore greatly improved. The proposed algorithm was first evaluated with computer simulations using a mathematical dynamic phantom. Experiment with a moving physical phantom was then carried out to demonstrate the accuracy of the proposed method and the increase of signal-to-noise ratio over three-dimensional PET. Finally, the 4D PET reconstruction was applied to a patient case

  19. Erroneous cardiac ECG-gated PET list-mode trigger events can be retrospectively identified and replaced by an offline reprocessing approach: first results in rodents

    International Nuclear Information System (INIS)

    Böning, Guido; Todica, Andrei; Vai, Alessandro; Lehner, Sebastian; Xiong, Guoming; Mille, Erik; Ilhan, Harun; Fougère, Christian la; Bartenstein, Peter; Hacker, Marcus

    2013-01-01

    The assessment of left ventricular function, wall motion and myocardial viability using electrocardiogram (ECG)-gated [ 18 F]-FDG positron emission tomography (PET) is widely accepted in human and in preclinical small animal studies. The nonterminal and noninvasive approach permits repeated in vivo evaluations of the same animal, facilitating the assessment of temporal changes in disease or therapy response. Although well established, gated small animal PET studies can contain erroneous gating information, which may yield to blurred images and false estimation of functional parameters. In this work, we present quantitative and visual quality control (QC) methods to evaluate the accuracy of trigger events in PET list-mode and physiological data. Left ventricular functional analysis is performed to quantify the effect of gating errors on the end-systolic and end-diastolic volumes, and on the ejection fraction (EF). We aim to recover the cardiac functional parameters by the application of the commonly established heart rate filter approach using fixed ranges based on a standardized population. In addition, we propose a fully reprocessing approach which retrospectively replaces the gating information of the PET list-mode file with appropriate list-mode decoding and encoding software. The signal of a simultaneously acquired ECG is processed using standard MATLAB vector functions, which can be individually adapted to reliably detect the R-peaks. Finally, the new trigger events are inserted into the PET list-mode file. A population of 30 mice with various health statuses was analyzed and standard cardiac parameters such as mean heart rate (119 ms ± 11.8 ms) and mean heart rate variability (1.7 ms ± 3.4 ms) derived. These standard parameter ranges were taken into account in the QC methods to select a group of nine optimal gated and a group of eight sub-optimal gated [ 18 F]-FDG PET scans of mice from our archive. From the list-mode files of the optimal gated group

  20. Robust framework for PET image reconstruction incorporating system and measurement uncertainties.

    Directory of Open Access Journals (Sweden)

    Huafeng Liu

    Full Text Available In Positron Emission Tomography (PET, an optimal estimate of the radioactivity concentration is obtained from the measured emission data under certain criteria. So far, all the well-known statistical reconstruction algorithms require exactly known system probability matrix a priori, and the quality of such system model largely determines the quality of the reconstructed images. In this paper, we propose an algorithm for PET image reconstruction for the real world case where the PET system model is subject to uncertainties. The method counts PET reconstruction as a regularization problem and the image estimation is achieved by means of an uncertainty weighted least squares framework. The performance of our work is evaluated with the Shepp-Logan simulated and real phantom data, which demonstrates significant improvements in image quality over the least squares reconstruction efforts.

  1. Assessment of metastatic colorectal cancer with hybrid imaging: comparison of reading performance using different combinations of anatomical and functional imaging techniques in PET/MRI and PET/CT in a short case series

    Energy Technology Data Exchange (ETDEWEB)

    Brendle, C.; Schwenzer, N.F.; Rempp, H.; Schmidt, H.; Pfannenberg, C.; Nikolaou, K.; Schraml, C. [Eberhard Karls University, Diagnostic and Interventional Radiology, Department of Radiology, Tuebingen (Germany); La Fougere, C. [Eberhard Karls University, Nuclear Medicine, Department of Radiology, Tuebingen (Germany)

    2016-01-15

    The purpose was to investigate the diagnostic performance of different combinations of anatomical and functional imaging techniques in PET/MRI and PET/CT for the evaluation of metastatic colorectal cancer lesions. Image data of 15 colorectal cancer patients (FDG-PET/CT and subsequent FDG-PET/MRI) were retrospectively evaluated by two readers in five reading sessions: MRI (morphology) alone, MRI/diffusion-weighted MRI (DWI), MRI/PET, MRI/DWI/PET; and PET/CT. Diagnostic performance of lesion detection with each combination was assessed in general and organ-based. The reference standard was given by histology and/or follow-up imaging. Separate analysis of mucinous tumours was performed. One hundred and eighty lesions (110 malignant) were evaluated (intestine n = 6, liver n = 37, lymph nodes n = 55, lung n = 4, and peritoneal n = 74). The overall lesion-based diagnostic accuracy was 0.46 for MRI, 0.47 for MRI/DWI, 0.57 for MRI/PET, 0.69 for MRI/DWI/PET and 0.66 for PET/CT. In the organ-based assessment, MRI/DWI/PET showed the highest accuracy for liver metastases (0.74), a comparable accuracy to PET/CT in peritoneal lesions (0.55), and in lymph node metastases (0.84). The accuracy in mucinous tumour lesions was limited in all modalities (MRI/DWI/PET = 0.52). PET/MRI including DWI is comparable to PET/CT in the evaluation of colorectal cancer metastases, with a markedly higher accuracy when using combined imaging data than the modalities separately. Further improvement is needed in the imaging of peritoneal carcinomatosis and mucinous tumours. (orig.)

  2. Initial tests of a prototype MRI-compatible PET imager

    Energy Technology Data Exchange (ETDEWEB)

    Raylman, Raymond R. [Center for Advanced Imaging, Department of Radiology, West Virginia University, HSB Box 9236, Morgantown, WV (United States)]. E-mail: rraylman@wvu.edu; Majewski, Stan [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Lemieux, Susan [Center for Advanced Imaging, Department of Radiology, West Virginia University, HSB Box 9236, Morgantown, WV (United States); Velan, S. Sendhil [Center for Advanced Imaging, Department of Radiology, West Virginia University, HSB Box 9236, Morgantown, WV (United States); Kross, Brain [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Popov, Vladimir [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Smith, Mark F. [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Weisenberger, Andrew G. [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Wojcik, Randy [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)

    2006-12-20

    Multi-modality imaging is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET fused with anatomical structure images created by MRI, will allow the correlation of form with function. Our group (a collaboration of West Virginia University and Jefferson Lab) is developing a system to acquire MRI and PET images contemporaneously. The prototype device consists of two opposed detector heads, operating in coincidence mode with an active FOV of 5x5x4 cm{sup 3}. Each MRI-PET detector module consists of an array of LSO detector elements (2.5x2.5x15 mm{sup 3}) coupled through a long fiber optic light guide to a single Hamamatsu flat panel PSPMT. The fiber optic light guide is made of a glued assembly of 2 mm diameter acrylic fibers with a total length of 2.5 m. The use of a light guides allows the PSPMTs to be positioned outside the bore of the 3 T General Electric MRI scanner used in the tests. Photon attenuation in the light guides resulted in an energy resolution of {approx}60% FWHM, interaction of the magnetic field with PSPMT further reduced energy resolution to {approx}85% FWHM. Despite this effect, excellent multi-plane PET and MRI images of a simple disk phantom were acquired simultaneously. Future work includes improved light guides, optimized magnetic shielding for the PSPMTs, construction of specialized coils to permit high-resolution MRI imaging, and use of the system to perform simultaneous PET and MRI or MR-spectroscopy.

  3. Pilot Study of 64CuCl2 for PET Imaging of Inflammation

    Directory of Open Access Journals (Sweden)

    Lei Jiang

    2018-02-01

    Full Text Available Copper(II ion (Cu2+ is the essential element for numerous pathophysiological processes in vivo. Copper transporter 1 (CTR1 is mainly responsible for maintaining Cu2+ accumulation in cells, which has been found to be over-expressed in inflammatory tissues. Therefore, we explored the potential application of 64CuCl2 for PET imaging of inflammation through targeting CTR1. The animal models of H2O2 induced muscle inflammation and lipopolysaccaharide induced lung inflammation were successfully established, then imaged by small animal PET (PET/CT post-injection of 64CuCl2, and PET images were quantitatively analyzed. H&E and immunohistochemical (IHC staining and western blot experiments were performed for evaluating CTR1 levels in the inflammatory and control tissues. Both inflammatory muscle and lungs can be clearly imaged by PET. PET image quantitative analysis revealed that the inflammatory muscle and lungs showed significantly higher 64Cu accumulation than the controls, respectively (p < 0.05. Furthermore, IHC staining and western blot analysis demonstrated that compared with the controls, CTR1 expression was increased in both the inflammatory muscle and lungs, which was consistent with the levels of 64Cu2+ accumulation in these tissues. 64CuCl2 can be used as a novel, simple, and highly promising PET tracer for CTR1 targeted imaging of inflammation.

  4. Molecular Imaging with Small Animal PET/CT

    DEFF Research Database (Denmark)

    Binderup, T.; El-Ali, H.H.; Skovgaard, D.

    2011-01-01

    is also described. In addition, the non-invasive nature of molecular imaging and the targets of these promising new tracers are attractive for other research areas as well, although these fields are much less explored. We present an example of an interesting research field with the application of small......Small animal positron emission tomography (PET) and computer tomography (CT) is an emerging field in pre-clinical imaging. High quality, state-of-the-art instruments are required for full optimization of the translational value of the small animal studies with PET and CT. However...... in this field of small animal molecular imaging with special emphasis on the targets for tissue characterization in tumor biology such as hypoxia, proliferation and cancer specific over-expression of receptors. The added value of applying CT imaging for anatomical localization and tumor volume measurements...

  5. Molecular imaging of head and neck cancers. Perspectives of PET/MRI; Molekulare Bildgebung bei Kopf-ï]¿Hals-Tumoren. Perspektive der PET-MRT

    Energy Technology Data Exchange (ETDEWEB)

    Stumpp, P.; Kahn, T. [Universitaetsklinikum Leipzig AoeR, Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Leipzig (Germany); Purz, S.; Sabri, O. [Universitaetsklinikum Leipzig, Klinik und Poliklinik fuer Nuklearmedizin, Leipzig (Germany)

    2016-07-15

    The {sup 18}F-fluorodeoxyglucose positron emission tomography-computed tomography ({sup 18}F-FDG-PET/CT) procedure is a cornerstone in the diagnostics of head and neck cancers. Several years ago PET-magnetic resonance imaging (PET/MRI) also became available as an alternative hybrid multimodal imaging method. Does PET/MRI have advantages over PET/CT in the diagnostics of head and neck cancers ?The diagnostic accuracy of the standard imaging methods CT, MRI and PET/CT is depicted according to currently available meta-analyses and studies concerning the use of PET/MRI for these indications are summarized. In all studies published up to now PET/MRI did not show superiority regarding the diagnostic accuracy in head and neck cancers; however, there is some evidence that in the future PET/MRI can contribute to tumor characterization and possibly be used to predict tumor response to therapy with the use of multiparametric imaging. Currently, {sup 18}F-FDG-PET/CT is not outperformed by PET/MRI in the diagnostics of head and neck cancers. The additive value of PET/MRI due to the use of multiparametric imaging needs to be investigated in future research. (orig.) [German] Die {sup 18}F-Fluordesoxyglukose-Positronenemissionstomographie-Computertomographie ({sup 18}F-FDG-PET-CT) hat ihren festen Stellenwert in der Diagnostik von Kopf-Hals-Tumoren. Seit einigen Jahren ist die PET-MRT als weitere hybride Bildgebungsmodalitaet verfuegbar. Bringt die PET-MRT Fortschritte bei der Diagnostik von Kopf-Hals-Tumoren ?Darstellung der diagnostischen Genauigkeit der bisherigen Bildgebungsmethoden CT, MRT und PET-CT anhand von Metaanalysen und Zusammenfassung der bisherigen Publikationen zur PET-MRT auf diesem Gebiet. Die PET-MRT zeigt in allen bisherigen Studien keine Ueberlegenheit bzgl. der diagnostischen Genauigkeit von Kopf-Hals-Tumoren. Sie kann jedoch durch die multiparametrische Diagnostik perspektivisch Beitraege zur Tumorcharakterisierung und damit moeglicherweise Voraussagen zum

  6. Repeatability of regional myocardial blood flow calculation in 82Rb PET imaging

    International Nuclear Information System (INIS)

    Knešaurek, Karin; Machac, Josef; Zhang, Zhuangyu

    2009-01-01

    We evaluated the repeatability of the calculation of myocardial blood flow (MBF) at rest and pharmacological stress, and calculated the coronary flow reserve (CFR) utilizing 82 Rb PET imaging. The aim of the research was to prove high repeatability for global MBF and CFR values and good repeatability for regional MBF and CFR values. The results will have significant impact on cardiac PET imaging in terms of making it more affordable and increasing its use. 12 normal volunteers were imaged at rest and during pharmacological stress, with 2220 MBq of 82 Rb each. A GE Advance PET system was used to acquire dynamic 50-frame studies. MBF was calculated with a 2-compartmental model using a modified PMOD program (PMOD; University Hospital Zurich, Zurich, Switzerland). Two differential equations, describing a 2-compartmental model, were solved by numerical integration and using Levenberg-Marquardt's method for fitting data. The PMOD program defines 16 standard segments and calculates myocardial flow for each segment, as well as average septal, anterior, lateral, inferior and global flow. Repeatability was evaluated according to the method of Bland and Altman. Global rest and stress MBF, as well as global CFR, showed very good repeatability. No significant differences were found between the paired resting global MBF (0.63 ± 0.13 vs. 0.64 ± 0.13 mL/min/g; mean difference, -1.0% ± 2.6%) and the stress global MBF (1.37 ± 0.23 vs. 1.37 ± 0.24; mean difference, 0.1% ± 2.3%). Global CFR was highly reproducible (2.25 ± 0.56 vs. 2.22 ± 0.54, P = not statistically significant; mean difference, 1.3% ± 14.3%). Repeatability coefficients for global rest MBF were 0.033 (5.2%) and stress MBF 0.062 (4.5%) mL/min/g. Regional rest and stress MBF and CFR have shown good reproducibility. The average per sector repeatability coefficients for rest MBF were 0.056 (8.5%) and stress MBF 0.089 (6.3%) mL/min/g, and average repeatability coefficient for CFR was 0.25 (10.6%). The results

  7. Cross sectional imaging of cardiac tumors

    International Nuclear Information System (INIS)

    Maksimovic, R.

    2012-01-01

    Full text: Primary cardiac tumors are a rare entity whose incidence, according to surgery and autopsy reports, is 0.3% to 0.7% of all cardiac tumors. Metastasis to the heart from other primary cancers is 30 times more common. Only 25% of primary cardiac tumors are malignant, and, of these, 75% are sarcomas. Malignant primary cardiac sarcomas are usually located in the right atrium and are most commonly angiosarcoma. In the left atrium, the most common malignant tumors are pleomorphic sarcoma and leiomyosarcoma. Symptom presentation for cardiac tumors is quite varied, but it is dependent upon tumor location and size, rather than upon histologic characteristics. Presentation includes congestive heart failure from intracardiac obstruction, systemic embolization, constitutional symptoms, and arrhythmias. Left atrial sarcomas tend to be more solid and less infiltrative than right-sided sarcomas; consequently, they tend to metastasize later. They usually present with symptoms of blood-flow obstruction and substantial, life-threatening congestive heart failure. Right-sided cardiac tumors are usually malignant and appear as bulky, infiltrative masses that grow in an outward pattern. These are usually fast-growing tumors that metastasize early and do not present with congestive heart failure until late in the disease. The diagnosis of cardiac tumors relies heavily on the use of multiple imaging techniques, including cardiac computed tomography (CT), cardiovascular magnetic resonance (CMR), and echocardiography. Important imaging data to collect include information on the size of the intracardiac mass, the mobility of the mass (an important predictor of prognosis and embolic potential), myocardial invasion, and cardiac chamber location. These factors will provide the means to diagnosis and prognosis. Other important data to collect include the mechanism of tumor implantation, the relationship of the tumor with adjacent structures, the surgeon route of access to the heart

  8. Dosimetry of FDG PET/CT and other molecular imaging applications in pediatric patients

    International Nuclear Information System (INIS)

    Gelfand, Michael J.

    2009-01-01

    Effective doses for PET and SPECT imaging of molecular imaging agents depend on the radiopharmaceutical, administered activity and the weight of the patient. Effective doses for the accompanying CT scan depend on the CT protocol being used. CT protocols can be designed to produce diagnostic quality images, localization images or attenuation correction data without imaging. In each case, the co-registered molecular imaging examination (PET or SPECT) and the CT study must be acquired without patient movement. For PET/CT, attention to the respiratory phase during the CT study is also of critical importance. In addition to the molecular imaging agents 18 F-FDG and 123 I-MIBG that are frequently used in children, additional PET and SPECT imaging agents may have promise for molecular imaging in children. (orig.)

  9. First-in-human uPAR PET: Imaging of Cancer Aggressiveness

    Science.gov (United States)

    Persson, Morten; Skovgaard, Dorthe; Brandt-Larsen, Malene; Christensen, Camilla; Madsen, Jacob; Nielsen, Carsten H.; Thurison, Tine; Klausen, Thomas Levin; Holm, Søren; Loft, Annika; Berthelsen, Anne Kiil; Ploug, Michael; Pappot, Helle; Brasso, Klaus; Kroman, Niels; Højgaard, Liselotte; Kjaer, Andreas

    2015-01-01

    A first-in-human clinical trial with Positron Emission Tomography (PET) imaging of the urokinase-type plasminogen activator receptor (uPAR) in patients with breast, prostate and bladder cancer, is described. uPAR is expressed in many types of human cancers and the expression is predictive of invasion, metastasis and indicates poor prognosis. uPAR PET imaging therefore holds promise to be a new and innovative method for improved cancer diagnosis, staging and individual risk stratification. The uPAR specific peptide AE105 was conjugated to the macrocyclic chelator DOTA and labeled with 64Cu for targeted molecular imaging with PET. The safety, pharmacokinetic, biodistribution profile and radiation dosimetry after a single intravenous dose of 64Cu-DOTA-AE105 were assessed by serial PET and computed tomography (CT) in 4 prostate, 3 breast and 3 bladder cancer patients. Safety assessment with laboratory blood screening tests was performed before and after PET ligand injection. In a subgroup of the patients, the in vivo stability of our targeted PET ligand was determined in collected blood and urine. No adverse or clinically detectable side effects in any of the 10 patients were found. The ligand exhibited good in vivo stability and fast clearance from plasma and tissue compartments by renal excretion. In addition, high uptake in both primary tumor lesions and lymph node metastases was seen and paralleled high uPAR expression in excised tumor tissue. Overall, this first-in-human study therefore provides promising evidence for safe use of 64Cu-DOTA-AE105 for uPAR PET imaging in cancer patients. PMID:26516369

  10. Dynamic comparison of PET imaging performance between state-of-the-art ToF-PET/CT and ToF-PET/MR scanners

    International Nuclear Information System (INIS)

    Delso, Gaspar; Deller, Tim; Khalighi, Mehdi; Veit-Haibach, Patrick; Schulthess, Gustav von

    2014-01-01

    The goal of the present work was to determine the potential for dose reduction in a new clinical ToF-PET/MR scanner. This was achieved by means of long dynamic phantom acquisitions designed to provide a fair comparison of image quality and lesion detectability, as a function of activity, between the new PET/MR system and a state-of-the art PET/CT.

  11. Improved frame-based estimation of head motion in PET brain imaging

    International Nuclear Information System (INIS)

    Mukherjee, J. M.; Lindsay, C.; King, M. A.; Licho, R.; Mukherjee, A.; Olivier, P.; Shao, L.

    2016-01-01

    Purpose: Head motion during PET brain imaging can cause significant degradation of image quality. Several authors have proposed ways to compensate for PET brain motion to restore image quality and improve quantitation. Head restraints can reduce movement but are unreliable; thus the need for alternative strategies such as data-driven motion estimation or external motion tracking. Herein, the authors present a data-driven motion estimation method using a preprocessing technique that allows the usage of very short duration frames, thus reducing the intraframe motion problem commonly observed in the multiple frame acquisition method. Methods: The list mode data for PET acquisition is uniformly divided into 5-s frames and images are reconstructed without attenuation correction. Interframe motion is estimated using a 3D multiresolution registration algorithm and subsequently compensated for. For this study, the authors used 8 PET brain studies that used F-18 FDG as the tracer and contained minor or no initial motion. After reconstruction and prior to motion estimation, known motion was introduced to each frame to simulate head motion during a PET acquisition. To investigate the trade-off in motion estimation and compensation with respect to frames of different length, the authors summed 5-s frames accordingly to produce 10 and 60 s frames. Summed images generated from the motion-compensated reconstructed frames were then compared to the original PET image reconstruction without motion compensation. Results: The authors found that our method is able to compensate for both gradual and step-like motions using frame times as short as 5 s with a spatial accuracy of 0.2 mm on average. Complex volunteer motion involving all six degrees of freedom was estimated with lower accuracy (0.3 mm on average) than the other types investigated. Preprocessing of 5-s images was necessary for successful image registration. Since their method utilizes nonattenuation corrected frames, it is

  12. Improved frame-based estimation of head motion in PET brain imaging

    Energy Technology Data Exchange (ETDEWEB)

    Mukherjee, J. M., E-mail: joyeeta.mitra@umassmed.edu; Lindsay, C.; King, M. A.; Licho, R. [Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts 01655 (United States); Mukherjee, A. [Aware, Inc., Bedford, Massachusetts 01730 (United States); Olivier, P. [Philips Medical Systems, Cleveland, Ohio 44143 (United States); Shao, L. [ViewRay, Oakwood Village, Ohio 44146 (United States)

    2016-05-15

    Purpose: Head motion during PET brain imaging can cause significant degradation of image quality. Several authors have proposed ways to compensate for PET brain motion to restore image quality and improve quantitation. Head restraints can reduce movement but are unreliable; thus the need for alternative strategies such as data-driven motion estimation or external motion tracking. Herein, the authors present a data-driven motion estimation method using a preprocessing technique that allows the usage of very short duration frames, thus reducing the intraframe motion problem commonly observed in the multiple frame acquisition method. Methods: The list mode data for PET acquisition is uniformly divided into 5-s frames and images are reconstructed without attenuation correction. Interframe motion is estimated using a 3D multiresolution registration algorithm and subsequently compensated for. For this study, the authors used 8 PET brain studies that used F-18 FDG as the tracer and contained minor or no initial motion. After reconstruction and prior to motion estimation, known motion was introduced to each frame to simulate head motion during a PET acquisition. To investigate the trade-off in motion estimation and compensation with respect to frames of different length, the authors summed 5-s frames accordingly to produce 10 and 60 s frames. Summed images generated from the motion-compensated reconstructed frames were then compared to the original PET image reconstruction without motion compensation. Results: The authors found that our method is able to compensate for both gradual and step-like motions using frame times as short as 5 s with a spatial accuracy of 0.2 mm on average. Complex volunteer motion involving all six degrees of freedom was estimated with lower accuracy (0.3 mm on average) than the other types investigated. Preprocessing of 5-s images was necessary for successful image registration. Since their method utilizes nonattenuation corrected frames, it is

  13. Establishment of the method of surface shaded display for brain PET imaging

    International Nuclear Information System (INIS)

    Zhang Xiangsong; Tang Anwu; He Zuoxiang

    2003-01-01

    Objective: To establish the method of surface shaded display (SSD) for brain PET imaging. Methods: The original brain PET images volume data were transferred to the personal computer by the local area network, and scaled into 256 grayscale values between 0 and 255. An appropriate threshold could be selected with three differential methods: depended on the histogram or maximum percentage of the volume data and the opposite value percentage of the lesion. The list of vertices and triangles describing the contour surface was produced with a high resolution three dimensional (3D) surface construction algorithm. Results: The final software of SSD for brain PET imaging with interactive user interface can produce 3D brain PET images which can be rotated, scaled, and saved or outputted with several image formats. Conclusion: The method of SSD for brain PET imaging can directly and integrally reflect the surface of brain cortex, and be helpful to locate lesions and display the range of lesions, but can not reflect the severity of lesions, nor can display the structure under brain cortex

  14. Standardised uptake values from PET/CT images: comparison with conventional attenuation-corrected PET

    International Nuclear Information System (INIS)

    Souvatzoglou, M.; Ziegler, S.I.; Martinez, M.J.; Dzewas, G.; Schwaiger, M.; Bengel, F.; Busch, R.

    2007-01-01

    In PET/CT, CT-derived attenuation factors may influence standardised uptake values (SUVs) in tumour lesions and organs when compared with stand-alone PET. Therefore, we compared PET/CT-derived SUVs intra-individually in various organs and tumour lesions with stand-alone PET-derived SUVs. Thirty-five patients with known or suspected cancer were prospectively included. Sixteen patients underwent FDG PET using an ECAT HR+scanner, and subsequently a second scan using a Biograph Sensation 16PET/CT scanner. Nineteen patients were scanned in the reverse order. All images were reconstructed with an iterative algorithm (OSEM). Suspected lesions were grouped as paradiaphragmatic versus distant from the diaphragm. Mean and maximum SUVs were also calculated for brain, lung, liver, spleen and vertebral bone. The attenuation coefficients (μ values) used for correction of emission data (bone, soft tissue, lung) in the two data sets were determined. A body phantom containing six hot spheres and one cold cylinder was measured using the same protocol as in patients. Forty-six lesions were identified. There was a significant correlation of maximum and mean SUVs derived from PET and PET/CT for 14 paradiaphragmatic lesions (r=0.97 respectively; p<0.001 respectively) and for 32 lesions located distant from the diaphragm (r=0.87 and r=0.89 respectively; p<0.001 respectively). No significant differences were observed in the SUVs calculated with PET and PET/CT in the lesions or in the organs. In the phantom, radioactivity concentration in spheres calculated from PET and from PET/CT correlated significantly (r=0.99; p<0.001). SUVs of cancer lesions and normal organs were comparable between PET and PET/CT, supporting the usefulness of PET/CT-derived SUVs for quantification of tumour metabolism. (orig.)

  15. Comparison of PET/CT with Sequential PET/MRI Using an MR-Compatible Mobile PET System.

    Science.gov (United States)

    Nakamoto, Ryusuke; Nakamoto, Yuji; Ishimori, Takayoshi; Fushimi, Yasutaka; Kido, Aki; Togashi, Kaori

    2018-05-01

    The current study tested a newly developed flexible PET (fxPET) scanner prototype. This fxPET system involves dual arc-shaped detectors based on silicon photomultipliers that are designed to fit existing MRI devices, allowing us to obtain fused PET and MR images by sequential PET and MR scanning. This prospective study sought to evaluate the image quality, lesion detection rate, and quantitative values of fxPET in comparison with conventional whole-body (WB) PET and to assess the accuracy of registration. Methods: Seventeen patients with suspected or known malignant tumors were analyzed. Approximately 1 h after intravenous injection of 18 F-FDG, WB PET/CT was performed, followed by fxPET and MRI. For reconstruction of fxPET images, MRI-based attenuation correction was applied. The quality of fxPET images was visually assessed, and the number of detected lesions was compared between the 2 imaging methods. SUV max and maximum average SUV within a 1 cm 3 spheric volume (SUV peak ) of lesions were also compared. In addition, the magnitude of misregistration between fxPET and MR images was evaluated. Results: The image quality of fxPET was acceptable for diagnosis of malignant tumors. There was no significant difference in detectability of malignant lesions between fxPET and WB PET ( P > 0.05). However, the fxPET system did not exhibit superior performance to the WB PET system. There were strong positive correlations between the 2 imaging modalities in SUV max (ρ = 0.88) and SUV peak (ρ = 0.81). SUV max and SUV peak measured with fxPET were approximately 1.1-fold greater than measured with WB PET. The average misregistration between fxPET and MR images was 5.5 ± 3.4 mm. Conclusion: Our preliminary data indicate that running an fxPET scanner near an existing MRI system provides visually and quantitatively acceptable fused PET/MR images for diagnosis of malignant lesions. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  16. Effects of attenuation and scatter corrections in cat brain PET images using microPET R4 scanner

    International Nuclear Information System (INIS)

    Kim, Jin Su; Lee, Jae Sung; Lee, Jong Jin

    2006-01-01

    The aim of this study was to examine the effects of attenuation correction (AC) and scatter correction (SC) on the quantification of PET count rates. To assess the effects of AC and SC, 18 F-FDG PET images of phantom and cat brain were acquired using microPET R4 scanner. Thirty-minute transmission images using 68 Ge source and emission images after injection of FDG were acquired. PET images were reconstructed using. 2D OSEM. AC and SC were applied. Regional count rates were measured using ROls drawn on cerebral cortex including frontal, parietal, and latral temporal lobes and deep gray matter including head of caudate nucleus, putamen and thalamus for pre- and post-AC and SC images. The count rates were then normalized with the injected dose per body weight. To assess the effects of AC, count ratio of 'deep gray matter/cerebral cortex' was calculated. To assess the effects of SC, ROls were also drawn on the gray matter (GM) and white matter (WM), and contrast between them ((GM-WM)/GM) was measured. After the AC, count ratio of 'deep gray matter/cerebral cortex' was increased by 17±7%. After the SC, contrast was also increased by 12±3%. Relative count of deep gray matter and contrast between gray and white matters were increased after AC and SC, suggesting that the AC would be critical for the quantitative analysis of cat brain PET data

  17. PET/CT Imaging and Radioimmunotherapy of Prostate Cancer

    DEFF Research Database (Denmark)

    Bouchelouche, Kirsten; Tagawa, Scott T; Goldsmith, Stanley J

    2011-01-01

    disease (ideal for antigen access and antibody delivery). Furthermore, prostate cancer is also radiation sensitive. Prostate-specific membrane antigen is expressed by virtually all prostate cancers, and represents an attractive target for RIT. Antiprostate-specific membrane antigen RIT demonstrates......Prostate cancer is a common cancer in men and continues to be a major health problem. Imaging plays an important role in the clinical management of patients with prostate cancer. An important goal for prostate cancer imaging is more accurate disease characterization through the synthesis...... of anatomic, functional, and molecular imaging information. Positron emission tomography (PET)/computed tomography (CT) in oncology is emerging as an important imaging tool. The most common radiotracer for PET/CT in oncology, (18)F-fluorodeoxyglucose (FDG), is not very useful in the imaging of prostate cancer...

  18. Registration and Summation of Respiratory-Gated or Breath-Hold PET Images Based on Deformation Estimation of Lung from CT Image

    Directory of Open Access Journals (Sweden)

    Hideaki Haneishi

    2016-01-01

    Full Text Available Lung motion due to respiration causes image degradation in medical imaging, especially in nuclear medicine which requires long acquisition times. We have developed a method for image correction between the respiratory-gated (RG PET images in different respiration phases or breath-hold (BH PET images in an inconsistent respiration phase. In the method, the RG or BH-PET images in different respiration phases are deformed under two criteria: similarity of the image intensity distribution and smoothness of the estimated motion vector field (MVF. However, only these criteria may cause unnatural motion estimation of lung. In this paper, assuming the use of a PET-CT scanner, we add another criterion that is the similarity for the motion direction estimated from inhalation and exhalation CT images. The proposed method was first applied to a numerical phantom XCAT with tumors and then applied to BH-PET image data for seven patients. The resultant tumor contrasts and the estimated motion vector fields were compared with those obtained by our previous method. Through those experiments we confirmed that the proposed method can provide an improved and more stable image quality for both RG and BH-PET images.

  19. A phantom study of tumor contouring on PET imaging

    International Nuclear Information System (INIS)

    Chen Song; Li Xuena; Li Yaming; Yin Yafu; Li Na; Han Chunqi

    2010-01-01

    Objective: To explore an algorithm to define the threshold value for tumor contouring on 18 F-fluorodeoxyglucose (FDG) PET imaging. Methods: A National Electrical Manufacturing Association (NEMA)NU 2 1994 PET phantom with 5 spheres of different diameters were filled with 18 F-FDG. Seven different sphere-to-background ratios were obtained and the phantom was scanned by Discovery LS 4. For each sphere-to-background ratio, the maximum standardized uptake value (SUV max ) of each sphere, the SUV of the border of each sphere (SUV border ), the mean SUV of a 1 cm region of background (SUV bg ) and the diameter (D) of each sphere were measured. SPSS 13.0 software was used for curve fitting and regression analysis to obtain the threshold algorithm. The calculated thresholds were applied to delineate 29 pathologically confirmed lung cancer lesions on PET images and the obtained volumes were compared with the volumes contoured on CT images in lung window. Results: The algorithm for defining contour threshold is TH% = 33.1% + 46.8% SUV bg /SUV max + 13.9%/D (r = 0.994) by phantom studies. For 29 lung cancer lesions, the average gross tumor volumes (GTV) delineated on PET and CT are (7.36±1.62) ml and (8.31±2.05) ml, respectively (t = -1.26, P>0.05). Conclusion: The proposed threshold algorithm for tumor contouring on PET image could provide comparable GTV with CT. (authors)

  20. Clinical feasibility of {sup 90}Y digital PET/CT for imaging microsphere biodistribution following radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Wright, Chadwick L.; Binzel, Katherine; Zhang, Jun; Knopp, Michael V. [The Ohio State University Wexner Medical Center, Wright Center of Innovation in Biomedical Imaging, Department of Radiology, Columbus, OH (United States); Wuthrick, Evan J. [The Ohio State University Wexner Medical Center, Department of Radiation Oncology, Columbus, OH (United States)

    2017-07-15

    The purpose of this study was to evaluate the clinical feasibility of next generation solid-state digital photon counting PET/CT (dPET/CT) technology and imaging findings in patients following {sup 90}Y microsphere radioembolization in comparison with standard of care (SOC) bremsstrahlung SPECT/CT (bSPECT/CT). Five patients underwent SOC {sup 90}Y bremsstrahlung imaging immediately following routine radioembolization with 3.5 ± 1.7 GBq of {sup 90}Y-labeled glass microspheres. All patients also underwent dPET/CT imaging at 29 ± 11 h following radioembolization. Matched pairs comparison was used to compare image quality, image contrast and {sup 90}Y biodistribution between dPET/CT and bSPECT/CT images. Volumetric assessments of {sup 90}Y activity using different isocontour thresholds on dPET/CT and bSPECT/CT images were also compared. Digital PET/CT consistently provided better visual image quality and {sup 90}Y-to-background image contrast while depicting {sup 90}Y biodistribution than bSPECT/CT. Isocontour volumetric assessment using a 1% threshold precisely outlined {sup 90}Y activity and the treatment volume on dPET/CT images, whereas a more restrictive 20% threshold on bSPECT/CT images was needed to obtain comparable treatment volumes. The use of a less restrictive 10% threshold isocontour on bSPECT/CT images grossly overestimated the treatment volume when compared with the 1% threshold on dPET/CT images. Digital PET/CT is clinically feasible for the assessment of {sup 90}Y microsphere biodistribution following radioembolization, and provides better visual image quality and image contrast than routine bSPECT/CT with comparable acquisition times. With further optimization and clinical validation, dPET technology may allow faster and more accurate imaging-based assessment of {sup 90}Y microsphere biodistribution. (orig.)

  1. Validation of PSF-based 3D reconstruction for myocardial blood flow measurements with Rb-82 PET

    DEFF Research Database (Denmark)

    Tolbod, Lars Poulsen; Christensen, Nana Louise; Møller, Lone W.

    images, filtered backprojection (FBP). Furthermore, since myocardial segmentation might be affected by image quality, two different approaches to segmentation implemented in standard software (Carimas (Turku PET Centre) and QPET (Cedar Sinai)) are utilized. Method:14 dynamic rest-stress Rb-82 patient......-scans performed on a GE Discovery 690 PET/CT were included. Images were reconstructed in an isotropic matrix (3.27x3.27x3.27 mm) using PSF (SharpIR: 3 iterations and 21 subsets) and FBP (FORE FBP) with the same edge-preserving filter (3D Butterworth: cut-off 10 mm, power 10). Analysis: The dynamic PET......Aim:The use of PSF-based 3D reconstruction algorithms (PSF) is desirable in most clinical PET-exams due to their superior image quality. Rb-82 cardiac PET is inherently noisy due to short half-life and prompt gammas and would presumably benefit from PSF. However, the quantitative behavior of PSF...

  2. Automated Segmentation of Cardiac Magnetic Resonance Images

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Nilsson, Jens Chr.; Grønning, Bjørn A.

    2001-01-01

    Magnetic resonance imaging (MRI) has been shown to be an accurate and precise technique to assess cardiac volumes and function in a non-invasive manner and is generally considered to be the current gold-standard for cardiac imaging [1]. Measurement of ventricular volumes, muscle mass and function...

  3. Reproducibility of Quantitative Brain Imaging Using a PET-Only and a Combined PET/MR System

    DEFF Research Database (Denmark)

    Lassen, Martin L; Muzik, Otto; Beyer, Thomas

    2017-01-01

    The purpose of this study was to test the feasibility of migrating a quantitative brain imaging protocol from a positron emission tomography (PET)-only system to an integrated PET/MR system. Potential differences in both absolute radiotracer concentration as well as in the derived kinetic paramet...

  4. Significance of the impact of motion compensation on the variability of PET image features

    Science.gov (United States)

    Carles, M.; Bach, T.; Torres-Espallardo, I.; Baltas, D.; Nestle, U.; Martí-Bonmatí, L.

    2018-03-01

    In lung cancer, quantification by positron emission tomography/computed tomography (PET/CT) imaging presents challenges due to respiratory movement. Our primary aim was to study the impact of motion compensation implied by retrospectively gated (4D)-PET/CT on the variability of PET quantitative parameters. Its significance was evaluated by comparison with the variability due to (i) the voxel size in image reconstruction and (ii) the voxel size in image post-resampling. The method employed for feature extraction was chosen based on the analysis of (i) the effect of discretization of the standardized uptake value (SUV) on complementarity between texture features (TF) and conventional indices, (ii) the impact of the segmentation method on the variability of image features, and (iii) the variability of image features across the time-frame of 4D-PET. Thirty-one PET-features were involved. Three SUV discretization methods were applied: a constant width (SUV resolution) of the resampling bin (method RW), a constant number of bins (method RN) and RN on the image obtained after histogram equalization (method EqRN). The segmentation approaches evaluated were 40% of SUVmax and the contrast oriented algorithm (COA). Parameters derived from 4D-PET images were compared with values derived from the PET image obtained for (i) the static protocol used in our clinical routine (3D) and (ii) the 3D image post-resampled to the voxel size of the 4D image and PET image derived after modifying the reconstruction of the 3D image to comprise the voxel size of the 4D image. Results showed that TF complementarity with conventional indices was sensitive to the SUV discretization method. In the comparison of COA and 40% contours, despite the values not being interchangeable, all image features showed strong linear correlations (r  >  0.91, p\\ll 0.001 ). Across the time-frames of 4D-PET, all image features followed a normal distribution in most patients. For our patient cohort, the

  5. EXPLORER: Changing the molecular imaging paradigm with total-body PET/CT (Conference Presentation)

    Science.gov (United States)

    Cherry, Simon R.; Badawi, Ramsey D.; Jones, Terry

    2016-04-01

    Positron emission tomography (PET) is the highest sensitivity technique for human whole-body imaging studies. However, current clinical PET scanners do not make full use of the available signal, as they only permit imaging of a 15-25 cm segment of the body at one time. Given the limited sensitive region, whole-body imaging with clinical PET scanners requires relatively long scan times and subjects the patient to higher than necessary radiation doses. The EXPLORER initiative aims to build a 2-meter axial length PET scanner to allow imaging the entire subject at once, capturing nearly the entire available PET signal. EXPLORER will acquire data with ~40-fold greater sensitivity leading to a six-fold increase in reconstructed signal-to-noise ratio for imaging the total body. Alternatively, total-body images with the EXPLORER scanner will be able to be acquired in ~30 seconds or with ~0.15 mSv injected dose, while maintaining current PET image quality. The superior sensitivity will open many new avenues for biomedical research. Specifically for cancer applications, high sensitivity PET will enable detection of smaller lesions. Additionally, greater sensitivity will allow imaging out to 10 half-lives of positron emitting radiotracers. This will enable 1) metabolic ultra-staging with FDG by extending the uptake and clearance time to 3-5 hours to significantly improve contrast and 2) improved kinetic imaging with short-lived radioisotopes such as C-11, crucial for drug development studies. Frequent imaging studies of the same subject to study disease progression or to track response to therapy will be possible with the low dose capabilities of the EXPLORER scanner. The low dose capabilities will also open up new imaging possibilities in pediatrics and adolescents to better study developmental disorders. This talk will review the basis for developing total-body PET, potential applications, and review progress to date in developing EXPLORER, the first total-body PET scanner.

  6. Multi-modality image reconstruction for dual-head small-animal PET

    International Nuclear Information System (INIS)

    Huang, Chang-Han; Chou, Cheng-Ying

    2015-01-01

    The hybrid positron emission tomography/computed tomography (PET/CT) or positron emission tomography/magnetic resonance imaging (PET/MRI) has become routine practice in clinics. The applications of multi-modality imaging can also benefit research advances. Consequently, dedicated small-imaging system like dual-head small-animal PET (DHAPET) that possesses the advantages of high detection sensitivity and high resolution can exploit the structural information from CT or MRI. It should be noted that the special detector arrangement in DHAPET leads to severe data truncation, thereby degrading the image quality. We proposed to take advantage of anatomical priors and total variation (TV) minimization methods to reconstruct PET activity distribution form incomplete measurement data. The objective is to solve the penalized least-squares function consisted of data fidelity term, TV norm and medium root priors. In this work, we employed the splitting-based fast iterative shrinkage/thresholding algorithm to split smooth and non-smooth functions in the convex optimization problems. Our simulations studies validated that the images reconstructed by use of the proposed method can outperform those obtained by use of conventional expectation maximization algorithms or that without considering the anatomical prior information. Additionally, the convergence rate is also accelerated.

  7. [Microdose clinical trial--impact of PET molecular imaging].

    Science.gov (United States)

    Yano, Tsuneo; Watanabe, Yasuyoshi

    2010-10-01

    Microdose (MD) clinical trial and exploratory IND study including sub-therapeutic dose and therapeutic dose which are higher than microdoses are expected to bring about innovations in drug development. The outlines of guidances for microdose clinical trial and ICH-M3 (R2) issued by the MHLW in June, 2008, and February, 2010, are first explained, respectively, and some examples of their application to clinical developments of therapeutic drugs in the infection and cancer fields are introduced. Especially, thanks to the progress of molecular imaging research, a new field of drug development is explored by using imaging biomarkers for efficacy or safety evaluation which visualize biomarkers by PET imaging agents. Finally, the roadmap for drug development in infection and cancer fields utilizing PET molecular imaging is discussed.

  8. Development and application of PET-MRI image fusion technology

    International Nuclear Information System (INIS)

    Song Jianhua; Zhao Jinhua; Qiao Wenli

    2011-01-01

    The emerging and growing in popularity of PET-CT scanner brings us the convenience and cognizes the advantages such as diagnosis, staging, curative effect evaluation and prognosis for malignant tumor. And the PET-MRI installing maybe a new upsurge when the machine gradually mature, because of the MRI examination without the radiation exposure and with the higher soft tissue resolution. This paper summarized the developing course of image fusion technology and some researches of clinical application about PET-MRI at present, in order to help people to understand the functions and know its wide application of the upcoming new instrument, mainly focuses the application on the central nervous system and some soft tissue lesions. And before PET-MRI popularization, people can still carry out some researches of various image fusion and clinical application on the current equipment. (authors)

  9. Discrimination and anatomical mapping of PET-positive lesions: comparison of CT attenuation-corrected PET images with coregistered MR and CT images in the abdomen

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, Felix P.; Crook, David W.; Mader, Caecilia E.; Appenzeller, Philippe; Schulthess, G.K. von; Schmid, Daniel T. [University Hospital Zurich, Department of Medical Radiology, Zurich (Switzerland)

    2013-01-15

    PET/MR has the potential to become a powerful tool in clinical oncological imaging. The purpose of this prospective study was to evaluate the performance of a single T1-weighted (T1w) fat-suppressed unenhanced MR pulse sequence of the abdomen in comparison with unenhanced low-dose CT images to characterize PET-positive lesions. A total of 100 oncological patients underwent sequential whole-body {sup 18}F-FDG PET with CT-based attenuation correction (AC), 40 mAs low-dose CT and two-point Dixon-based T1w 3D MRI of the abdomen in a trimodality PET/CT-MR system. PET-positive lesions were assessed by CT and MRI with regard to their anatomical location, conspicuity and additional relevant information for characterization. From among 66 patients with at least one PET-positive lesion, 147 lesions were evaluated. No significant difference between MRI and CT was found regarding anatomical lesion localization. The MR pulse sequence used performed significantly better than CT regarding conspicuity of liver lesions (p < 0.001, Wilcoxon signed ranks test), whereas no difference was noted for extrahepatic lesions. For overall lesion characterization, MRI was considered superior to CT in 40 % of lesions, equal to CT in 49 %, and inferior to CT in 11 %. Fast Dixon-based T1w MRI outperformed low-dose CT in terms of conspicuity and characterization of PET-positive liver lesions and performed similarly in extrahepatic tumour manifestations. Hence, under the assumption that the technical issue of MR AC for whole-body PET examinations is solved, in abdominal PET/MR imaging the replacement of low-dose CT by a single Dixon-based MR pulse sequence for anatomical lesion correlation appears to be valid and robust. (orig.)

  10. Discrimination and anatomical mapping of PET-positive lesions: comparison of CT attenuation-corrected PET images with coregistered MR and CT images in the abdomen

    International Nuclear Information System (INIS)

    Kuhn, Felix P.; Crook, David W.; Mader, Caecilia E.; Appenzeller, Philippe; Schulthess, G.K. von; Schmid, Daniel T.

    2013-01-01

    PET/MR has the potential to become a powerful tool in clinical oncological imaging. The purpose of this prospective study was to evaluate the performance of a single T1-weighted (T1w) fat-suppressed unenhanced MR pulse sequence of the abdomen in comparison with unenhanced low-dose CT images to characterize PET-positive lesions. A total of 100 oncological patients underwent sequential whole-body 18 F-FDG PET with CT-based attenuation correction (AC), 40 mAs low-dose CT and two-point Dixon-based T1w 3D MRI of the abdomen in a trimodality PET/CT-MR system. PET-positive lesions were assessed by CT and MRI with regard to their anatomical location, conspicuity and additional relevant information for characterization. From among 66 patients with at least one PET-positive lesion, 147 lesions were evaluated. No significant difference between MRI and CT was found regarding anatomical lesion localization. The MR pulse sequence used performed significantly better than CT regarding conspicuity of liver lesions (p < 0.001, Wilcoxon signed ranks test), whereas no difference was noted for extrahepatic lesions. For overall lesion characterization, MRI was considered superior to CT in 40 % of lesions, equal to CT in 49 %, and inferior to CT in 11 %. Fast Dixon-based T1w MRI outperformed low-dose CT in terms of conspicuity and characterization of PET-positive liver lesions and performed similarly in extrahepatic tumour manifestations. Hence, under the assumption that the technical issue of MR AC for whole-body PET examinations is solved, in abdominal PET/MR imaging the replacement of low-dose CT by a single Dixon-based MR pulse sequence for anatomical lesion correlation appears to be valid and robust. (orig.)

  11. Restoration of the analytically reconstructed OpenPET images by the method of convex projections

    Energy Technology Data Exchange (ETDEWEB)

    Tashima, Hideaki; Murayama, Hideo; Yamaya, Taiga [National Institute of Radiological Sciences, Chiba (Japan); Katsunuma, Takayuki; Suga, Mikio [Chiba Univ. (Japan). Graduate School of Engineering; Kinouchi, Shoko [National Institute of Radiological Sciences, Chiba (Japan); Chiba Univ. (Japan). Graduate School of Engineering; Obi, Takashi [Tokyo Institute of Technology (Japan). Interdisciplinary Graduate School of Science and Engineering; Kudo, Hiroyuki [Tsukuba Univ. (Japan). Graduate School of Systems and Information Engineering

    2011-07-01

    We have proposed the OpenPET geometry which has gaps between detector rings and physically opened field-of-view. The image reconstruction of the OpenPET is classified into an incomplete problem because it does not satisfy the Orlov's condition. Even so, the simulation and experimental studies have shown that applying iterative methods such as the maximum likelihood expectation maximization (ML-EM) algorithm successfully reconstruct images in the gap area. However, the imaging process of the iterative methods in the OpenPET imaging is not clear. Therefore, the aim of this study is to analytically analyze the OpenPET imaging and estimate implicit constraints involved in the iterative methods. To apply explicit constraints in the OpenPET imaging, we used the method of convex projections for restoration of the images reconstructed by the analytical way in which low-frequency components are lost. Numerical simulations showed that the similar restoration effects are involved both in the ML-EM and the method of convex projections. Therefore, the iterative methods have advantageous effect of restoring lost frequency components of the OpenPET imaging. (orig.)

  12. 18F-FDG-PET/CT Angiography for the Diagnosis of Infective Endocarditis.

    Science.gov (United States)

    Roque, A; Pizzi, M N; Cuéllar-Calàbria, H; Aguadé-Bruix, S

    2017-02-01

    This article reviews the current imaging role of 18 F-fluordeoxyglucose positron emission computed tomography ( 18 F-FDG-PET/CT) combined with cardiac CT angiography (CTA) in infective endocarditis and discusses the strengths and limitations of this technique. The diagnosis of infective endocarditis affecting prosthetic valves and intracardiac devices is challenging because echocardiography and, therefore, the modified Duke criteria have well-recognized limitations in this clinical scenario. The high sensitivity of 18 F-FDG-PET/CT for the detection of infection associated with the accurate definition of structural damage by gated cardiac CTA in a combined technique (PET/CTA) has provided a significant increase in diagnostic sensitivity for the detection of IE. PET/CTA has proven to be a useful diagnostic tool in patients with suspected infective endocarditis. The additional information provided by this technique improves diagnostic performance in prosthetic valve endocarditis when it is used in combination with the Duke criteria. The findings obtained in PET/CTA studies have been included as a major criterion in the recently updated diagnostic algorithm in infective endocarditis guidelines.

  13. PET image reconstruction using multi-parametric anato-functional priors

    Science.gov (United States)

    Mehranian, Abolfazl; Belzunce, Martin A.; Niccolini, Flavia; Politis, Marios; Prieto, Claudia; Turkheimer, Federico; Hammers, Alexander; Reader, Andrew J.

    2017-08-01

    In this study, we investigate the application of multi-parametric anato-functional (MR-PET) priors for the maximum a posteriori (MAP) reconstruction of brain PET data in order to address the limitations of the conventional anatomical priors in the presence of PET-MR mismatches. In addition to partial volume correction benefits, the suitability of these priors for reconstruction of low-count PET data is also introduced and demonstrated, comparing to standard maximum-likelihood (ML) reconstruction of high-count data. The conventional local Tikhonov and total variation (TV) priors and current state-of-the-art anatomical priors including the Kaipio, non-local Tikhonov prior with Bowsher and Gaussian similarity kernels are investigated and presented in a unified framework. The Gaussian kernels are calculated using both voxel- and patch-based feature vectors. To cope with PET and MR mismatches, the Bowsher and Gaussian priors are extended to multi-parametric priors. In addition, we propose a modified joint Burg entropy prior that by definition exploits all parametric information in the MAP reconstruction of PET data. The performance of the priors was extensively evaluated using 3D simulations and two clinical brain datasets of [18F]florbetaben and [18F]FDG radiotracers. For simulations, several anato-functional mismatches were intentionally introduced between the PET and MR images, and furthermore, for the FDG clinical dataset, two PET-unique active tumours were embedded in the PET data. Our simulation results showed that the joint Burg entropy prior far outperformed the conventional anatomical priors in terms of preserving PET unique lesions, while still reconstructing functional boundaries with corresponding MR boundaries. In addition, the multi-parametric extension of the Gaussian and Bowsher priors led to enhanced preservation of edge and PET unique features and also an improved bias-variance performance. In agreement with the simulation results, the clinical results

  14. Single photon image from PET with insertable collimator for boron neutron capture therapy

    International Nuclear Information System (INIS)

    Jung, Jooyoung; Suh, Tae Suk; Hong, Key Jo

    2014-01-01

    Boron neutron capture therapy (BNCT) is a radiation therapy technique for treating deep-seated brain tumors by irradiation with a thermal neutron in which boron-labelled low molecular weight compounds. Once completed, a single photon emission computed tomography (SPECT) scan is conducted to investigate for the region of therapy using an isotope exclusive to SPECT. In the case of an existing PET/SPECT combination system, at least two types of isotopes should be used for each scan with their purposes. Recently, researchers examined the effects of PET/SPECT dual modality on animal imaging systems. They reported that the PET/SPECT combination system was effective for simultaneous achievement of a single event and coincidence. The aim of our proposed system is to confirm the feasibility of extraction of two types of images from one PET module with an insertable collimator for brain tumor treatment during the BNCT. We attempted to acquire the PET and SPECT images simultaneously using only PET without an additional isotope. Single photon images were acquired using an insertable collimator on a PET detector

  15. 90Y microsphere therapy: does 90Y PET/CT imaging obviate the need for 90Y Bremsstrahlung SPECT/CT imaging?

    Science.gov (United States)

    Zade, Anand A; Rangarajan, Venkatesh; Purandare, Nilendu C; Shah, Sneha A; Agrawal, Archi R; Kulkarni, Suyash S; Shetty, Nitin

    2013-11-01

    Transarterial radioembolization using Y microspheres is a novel therapeutic option for inoperable hepatic malignancies. As these spheres are radiolucent, real-time assessment of their distribution during the infusion process under fluoroscopic guidance is not possible. Bremsstrahlung radiations arising from 90Y have conventionally been used for imaging its biodistribution. Recent studies have proved that sources of 90Y also emit positrons, which can further be used for PET/computed tomography (CT) imaging. This study aimed to assess the feasibility of 90Y PET/CT imaging in evaluating microsphere distributions and to compare its findings with those of Bremsstrahlung imaging. Thirty-five sessions of 90Y microsphere transarterial radioembolization were performed on 30 patients with hepatic malignancies. 90Y PET/CT imaging was performed within 3 h of therapy. Bremsstrahlung imaging was also performed for each patient. The imaging findings were compared for concordance in the distribution of microspheres. Exact one-to-one correspondence between 90Y PET/CT imaging and 90Y Bremsstrahlung imaging was observed in 97.14% of cases (i.e. in 34/35 cases). Discordance was observed only in one case in which 90Y PET/CT imaging resolved the microsphere uptake in the inferior vena cava tumor thrombus, which was, however, not visualized on Bremsstrahlung imaging. There is good concordance in the imaging findings of 90Y PET/CT and 90Y Bremsstrahlung imaging. 90Y PET/CT imaging scores over the conventionally used Bremsstrahlung imaging in terms of better resolution, ease of technique, and comparable image acquisition time. This makes it a preferred imaging modality for assessment of the distribution of 90Y microspheres.

  16. Contourlet-based active contour model for PET image segmentation

    NARCIS (Netherlands)

    Abdoli, M.; Dierckx, R. A. J. O.; Zaidi, H.

    Purpose: PET-guided radiation therapy treatment planning, clinical diagnosis, assessment of tumor growth, and therapy response rely on the accurate delineation of the tumor volume and quantification of tracer uptake. Most PET image segmentation techniques proposed thus far are suboptimal in the

  17. {sup 18}F-FDOPA PET/CT imaging of insulinoma revisited

    Energy Technology Data Exchange (ETDEWEB)

    Imperiale, Alessio; Namer, Izzie-Jacques [University Hospitals of Strasbourg, Department of Biophysics and Nuclear Medicine, Strasbourg (France); University of Strasbourg/CNRS and FMTS, Faculty of Medicine, ICube - UMR 7357, Strasbourg (France); Sebag, Frederic [Aix-Marseille University, Department of Endocrine Surgery, La Timone University Hospital, Marseille (France); Vix, Michel [University of Strasbourg, Department of General, Digestive, and Endocrine Surgery, IRCAD-IHU, Strasbourg (France); Castinetti, Frederic [Aix-Marseille University, Department of Endocrinology, Diabetes and Metabolic Disorders, La Timone University Hospital, Marseille (France); Kessler, Laurence; Moreau, Francois [University of Strasbourg, Department of Diabetology, University Hospital of Strasbourg, Strasbourg (France); Bachellier, Philippe [University Hospitals of Strasbourg, Department of Visceral Surgery and Transplantation, Strasbourg (France); Guillet, Benjamin; Mundler, Olivier [Aix-Marseille University, Department of Nuclear Medicine, La Timone University Hospital, CERIMED, Marseille (France); Taieb, David [Aix-Marseille University, Department of Nuclear Medicine, La Timone University Hospital, CERIMED, Marseille (France); Aix-Marseille University, Biophysics and Nuclear Medecine, La Timone University Hospital, European Center for Research in Medical Imaging, Marseille (France)

    2014-11-01

    {sup 18}F-FDOPA PET imaging is increasingly used in the work-up of patients with neuroendocrine tumours. It has been shown to be of limited value in localizing pancreatic insulin-secreting tumours in adults with hyperinsulinaemic hypoglycaemia (HH) mainly due to {sup 18}F-FDOPA uptake by the whole pancreatic gland. The objective of this study was to review our experience with {sup 18}F-FDOPA PET/CT imaging with carbidopa (CD) premedication in patients with HH in comparison with PET/CT studies performed without CD premedication in an independent population. A retrospective study including 16 HH patients who were investigated between January 2011 and December 2013 using {sup 18}F-FDOPA PET/CT (17 examinations) in two academic endocrine tumour centres was conducted. All PET/CT examinations were performed under CD premedication (200 mg orally, 1 - 2 h prior to tracer injection). The PET/CT acquisition protocol included an early acquisition (5 min after {sup 18}F-FDOPA injection) centred over the upper abdomen and a delayed whole-body acquisition starting 20 - 30 min later. An independent series of eight consecutive patients with HH and investigated before 2011 were considered for comparison. All patients had a reference whole-body PET/CT scan performed about 1 h after {sup 18}F-FDOPA injection. In all cases, PET/CT was performed without CD premedication. In the study group, {sup 18}F-FDOPA PET/CT with CD premedication was positive in 8 out of 11 patients with histologically proven insulinoma (73 %). All {sup 18}F-FDOPA PET/CT-avid insulinomas were detected on early images and 5 of 11 (45 %) on delayed ones. The tumour/normal pancreas uptake ratio was not significantly different between early and delayed acquisitions. Considering all patients with HH, including those without imaging evidence of disease, the detection rate of the primary lesions using CD-assisted {sup 18}F-FDOPA PET/CT was 53 %, showing 9 insulinomas in 17 studies performed. In the control group (without

  18. [Evaluation of new technologies PET/CT nuclear imaging].

    Science.gov (United States)

    Giraldes, Maria Rosário

    2010-01-01

    Nuclear imaging has used initially anatomic and volumetric technologies as CT or MRI. In recent years new dimensions of non invasive studies, as PET, have shown a higher utility in the effectiveness of the treatment. The evaluation of need must be done according to a principle of Horizontal Equity, equal treatment for equal need and of a principle of Vertical Equity, Different treatment, at regional level, according to each hospital level. The evaluation of need has been made according to the Potential Demand by Potential User Groups: diabetes, type 2, (50 years and more); screening colorectal (50 years and more); morbidity by cancer; surgery of lung cancer; cardiology; heart surgery; acute chest pain in the emergency department. In a Macro Perspective need has been evaluated using the Population Estimations for 2007, at municipality level. Relatively to Lisbon and Porto data at locality level has been used, from the 2001 Census. According to Campos, J.R. (2007), in 2006, it existed 1 PET by 1 million inhabitants and after that date 2 more were created (Quadrantes and Hospital ad Luz), belonging to the private sector. Mores 15 PET are needed in the NHS, 1 PET for about 504128 inhabitants. According to The Potential Demand perspective 18 new PET are needed, 15 from the public sector. The private sector will cover progressively the demand. Dorado and Albertino (2002), in Spain, mention that the introduction of this new technique in our Health System must be done slowly due to the cost and complexity. In Portugal exists already 6 PET and this applies also. As a first priority the intervention in Oncology in the IPO (Coimbra). A priority must be given to the University Hospitals of Santa Maria and São João. The Central Hospitals of Viseu and VilaReal/Régua must have also 1 PET. A priority must be given to the interior in order to avoid transports of patients and families. In fourth place the HC Central Lisbon must have also 1 PET, which will go to the New Hospital

  19. Fully three-dimensional image reconstruction in radiology and nuclear medicine. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-07-01

    The proceedings of the meeting on ''fully three-dimensional image reconstruction in radiology and nuclear medicine'' covers contributions on the following topics: CT imaging, PET imaging, fidelity; iterative and few-view CT, CT-analytical; PET/SPECT Compton analytical; doses - spectral methods; phase contrast; compressed sensing- sparse reconstruction; special issues; motion - cardiac.

  20. Impact of metal artefacts due to EEG electrodes in brain PET/CT imaging

    International Nuclear Information System (INIS)

    Lemmens, Catherine; Nuyts, Johan; Dupont, Patrick; Montandon, Marie-Louise; Ratib, Osman; Zaidi, Habib

    2008-01-01

    The goal of this study is to investigate the impact of electroencephalogram (EEG) electrodes on the visual quality and quantification of 18 F-FDG PET images in neurological PET/CT examinations. For this purpose, the scans of 20 epilepsy patients with EEG monitoring were used. The CT data were reconstructed with filtered backprojection (FBP) and with a metal artefact reduction (MAR) algorithm. Both data sets were used for CT-based attenuation correction (AC) of the PET data. Also, a calculated AC (CALC) technique was considered. A volume of interest (VOI)-based analysis and a voxel-based quantitative analysis were performed to compare the different AC methods. Images were also evaluated visually by two observers. It was shown with simulations and phantom measurements that from the considered AC methods, the MAR-AC can be used as the reference in this setting. The visual assessment of PET images showed local hot spots outside the brain corresponding to the locations of the electrodes when using FBP-AC. In the brain, no abnormalities were observed. The quantitative analysis showed a very good correlation between PET-FBP-AC and PET-MAR-AC, with a statistically significant positive bias in the PET-FBP-AC images of about 5-7% in most brain voxels. There was also good correlation between PET-CALC-AC and PET-MAR-AC, but in the PET-CALC-AC images, regions with both a significant positive and negative bias were observed. EEG electrodes give rise to local hot spots outside the brain and a positive quantification bias in the brain. However, when diagnosis is made by mere visual assessment, the presence of EEG electrodes does not seem to alter the diagnosis. When quantification is performed, the bias becomes an issue especially when comparing brain images with and without EEG monitoring

  1. Impact of metal artefacts due to EEG electrodes in brain PET/CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lemmens, Catherine; Nuyts, Johan; Dupont, Patrick [Department of Nuclear Medicine and Medical Imaging Center, University Hospital Gasthuisberg and Katholieke Universiteit Leuven, Leuven (Belgium); Montandon, Marie-Louise; Ratib, Osman; Zaidi, Habib [Division of Nuclear Medicine, Geneva University Hospital, CH-1211 Geneva (Switzerland)], E-mail: catherine.lemmens@uz.kuleuven.be

    2008-08-21

    The goal of this study is to investigate the impact of electroencephalogram (EEG) electrodes on the visual quality and quantification of {sup 18}F-FDG PET images in neurological PET/CT examinations. For this purpose, the scans of 20 epilepsy patients with EEG monitoring were used. The CT data were reconstructed with filtered backprojection (FBP) and with a metal artefact reduction (MAR) algorithm. Both data sets were used for CT-based attenuation correction (AC) of the PET data. Also, a calculated AC (CALC) technique was considered. A volume of interest (VOI)-based analysis and a voxel-based quantitative analysis were performed to compare the different AC methods. Images were also evaluated visually by two observers. It was shown with simulations and phantom measurements that from the considered AC methods, the MAR-AC can be used as the reference in this setting. The visual assessment of PET images showed local hot spots outside the brain corresponding to the locations of the electrodes when using FBP-AC. In the brain, no abnormalities were observed. The quantitative analysis showed a very good correlation between PET-FBP-AC and PET-MAR-AC, with a statistically significant positive bias in the PET-FBP-AC images of about 5-7% in most brain voxels. There was also good correlation between PET-CALC-AC and PET-MAR-AC, but in the PET-CALC-AC images, regions with both a significant positive and negative bias were observed. EEG electrodes give rise to local hot spots outside the brain and a positive quantification bias in the brain. However, when diagnosis is made by mere visual assessment, the presence of EEG electrodes does not seem to alter the diagnosis. When quantification is performed, the bias becomes an issue especially when comparing brain images with and without EEG monitoring.

  2. F-18 FDG PET/CT imaging of primary hepatic neuroendocrine tumor

    Directory of Open Access Journals (Sweden)

    Katsuya Mitamura

    2015-01-01

    Full Text Available Primary hepatic neuroendocrine tumors (PHNETs are extremely rare neoplasms. Herein, we report a case of a 70-year-old man with a hepatic mass. The non-contrast computed tomography (CT image showed a low-density mass, and dynamic CT images indicated the enhancement of the mass in the arterial phase and early washout in the late phase. F18- fluorodeoxyglucose (18F-FDG positron emission tomography (PET and fused PET/CT images showed increased uptake in the hepatic mass. Whole-body 18F-FDG PET images showed no abnormal activity except for the liver lesion. Presence of an extrahepatic tumor was also ruled out by performing upper gastrointestinal endoscopy, total colonoscopy, and chest and abdominal CT. A posterior segmentectomy was performed, and histologic examination confirmed a neuroendocrine tumor (grade 1. The patient was followed up for about 2 years after the resection, and no extrahepatic lesions were radiologically found. Therefore, the patient was diagnosed with PHNET. To the best of our knowledge, no previous case of PHNET have been detected by 18F-FDG PET imaging.

  3. Local respiratory motion correction for PET/CT imaging: Application to lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lamare, F., E-mail: frederic.lamare@chu-bordeaux.fr; Fernandez, P. [INCIA, UMR 5287, University of Bordeaux, Talence F-33400, France and Nuclear Medicine Department, University Hospital, Bordeaux 33000 (France); Fayad, H.; Visvikis, D. [INSERM, UMR1101, LaTIM, Université de Bretagne Occidentale, Brest 29609 (France)

    2015-10-15

    Purpose: Despite multiple methodologies already proposed to correct respiratory motion in the whole PET imaging field of view (FOV), such approaches have not found wide acceptance in clinical routine. An alternative can be the local respiratory motion correction (LRMC) of data corresponding to a given volume of interest (VOI: organ or tumor). Advantages of LRMC include the use of a simple motion model, faster execution times, and organ specific motion correction. The purpose of this study was to evaluate the performance of LMRC using various motion models for oncology (lung lesion) applications. Methods: Both simulated (NURBS based 4D cardiac-torso phantom) and clinical studies (six patients) were used in the evaluation of the proposed LRMC approach. PET data were acquired in list-mode and synchronized with respiration. The implemented approach consists first in defining a VOI on the reconstructed motion average image. Gated PET images of the VOI are subsequently reconstructed using only lines of response passing through the selected VOI and are used in combination with a center of gravity or an affine/elastic registration algorithm to derive the transformation maps corresponding to the respiration effects. Those are finally integrated in the reconstruction process to produce a motion free image over the lesion regions. Results: Although the center of gravity or affine algorithm achieved similar performance for individual lesion motion correction, the elastic model, applied either locally or to the whole FOV, led to an overall superior performance. The spatial tumor location was altered by 89% and 81% for the elastic model applied locally or to the whole FOV, respectively (compared to 44% and 39% for the center of gravity and affine models, respectively). This resulted in similar associated overall tumor volume changes of 84% and 80%, respectively (compared to 75% and 71% for the center of gravity and affine models, respectively). The application of the nonrigid

  4. Detecting early cardiac dysfunction with radionuclide cardiac blood-pool imaging

    International Nuclear Information System (INIS)

    Wu Kegui; Chen Daguang; Lin Haoxue

    1992-01-01

    Cardiac function was measured by radionuclide cardiac blood-pool imaging in 15 normal persons, 19 cases of hypertension, 32 cases of coronary heart disease, 35 cases of coronary heart disease combined with hypertension and 44 cases of myocardial infarction. Significant differences have been found in indices of cardiac function between normal subjects and patients with coronary heart disease and coronary heart disease combined with hypertension, even though the patients were without any clinical sin of cardiac failure. Lowered regional EF and decreased ventricular was motion were found in 38.8% of patients, while 65.7%of patients revealed marked abnormality in MFR. The results indicate that latent cardiac dysfunction is common in patients with coronary heart disease. The earliest change is diastolic function abnormalities

  5. Multimodal imaging utilising integrated MR-PET for human brain tumour assessment

    International Nuclear Information System (INIS)

    Neuner, Irene; Kaffanke, Joachim B.; Langen, Karl-Josef; Kops, Elena Rota; Tellmann, Lutz; Stoffels, Gabriele; Weirich, Christoph; Filss, Christian; Scheins, Juergen; Herzog, Hans; Shah, N. Jon

    2012-01-01

    The development of integrated magnetic resonance (MR)-positron emission tomography (PET) hybrid imaging opens up new horizons for imaging in neuro-oncology. In cerebral gliomas the definition of tumour extent may be difficult to ascertain using standard MR imaging (MRI) only. The differentiation of post-therapeutic scar tissue, tumour rests and tumour recurrence is challenging. The relationship to structures such as the pyramidal tract to the tumour mass influences the therapeutic neurosurgical approach. The diagnostic information may be enriched by sophisticated MR techniques such as diffusion tensor imaging (DTI), multiple-volume proton MR spectroscopic imaging (MRSI) and functional MRI (fMRI). Metabolic imaging with PET, especially using amino acid tracers such as 18 F-fluoroethyl-l-tyrosine (FET) or 11 C-l-methionine (MET) will indicate tumour extent and response to treatment. The new technologies comprising MR-PET hybrid systems have the advantage of providing comprehensive answers by a one-stop-job of 40-50 min. The combined approach provides data of different modalities using the same iso-centre, resulting in optimal spatial and temporal realignment. All images are acquired exactly under the same physiological conditions. We describe the imaging protocol in detail and provide patient examples for the different imaging modalities such as FET-PET, standard structural imaging (T1-weighted, T2-weighted, T1-weighted contrast agent enhanced), DTI, MRSI and fMRI. (orig.)

  6. Multimodal imaging utilising integrated MR-PET for human brain tumour assessment

    Energy Technology Data Exchange (ETDEWEB)

    Neuner, Irene [Institute of Neuroscience and Medicine 4, INM 4, Juelich (Germany); RWTH Aachen University, Department of Psychiatry, Psychotherapy and Psychosomatics, Aachen (Germany); JARA-BRAIN-Translational Medicine, Aachen (Germany); Kaffanke, Joachim B. [Institute of Neuroscience and Medicine 4, INM 4, Juelich (Germany); MR-Transfer e.K., Wuppertal (Germany); Langen, Karl-Josef; Kops, Elena Rota; Tellmann, Lutz; Stoffels, Gabriele; Weirich, Christoph; Filss, Christian; Scheins, Juergen; Herzog, Hans [Institute of Neuroscience and Medicine 4, INM 4, Juelich (Germany); Shah, N. Jon [Institute of Neuroscience and Medicine 4, INM 4, Juelich (Germany); RWTH Aachen University, Department of Neurology, Aachen (Germany); JARA-BRAIN-Translational Medicine, Aachen (Germany)

    2012-12-15

    The development of integrated magnetic resonance (MR)-positron emission tomography (PET) hybrid imaging opens up new horizons for imaging in neuro-oncology. In cerebral gliomas the definition of tumour extent may be difficult to ascertain using standard MR imaging (MRI) only. The differentiation of post-therapeutic scar tissue, tumour rests and tumour recurrence is challenging. The relationship to structures such as the pyramidal tract to the tumour mass influences the therapeutic neurosurgical approach. The diagnostic information may be enriched by sophisticated MR techniques such as diffusion tensor imaging (DTI), multiple-volume proton MR spectroscopic imaging (MRSI) and functional MRI (fMRI). Metabolic imaging with PET, especially using amino acid tracers such as {sup 18}F-fluoroethyl-l-tyrosine (FET) or {sup 11}C-l-methionine (MET) will indicate tumour extent and response to treatment. The new technologies comprising MR-PET hybrid systems have the advantage of providing comprehensive answers by a one-stop-job of 40-50 min. The combined approach provides data of different modalities using the same iso-centre, resulting in optimal spatial and temporal realignment. All images are acquired exactly under the same physiological conditions. We describe the imaging protocol in detail and provide patient examples for the different imaging modalities such as FET-PET, standard structural imaging (T1-weighted, T2-weighted, T1-weighted contrast agent enhanced), DTI, MRSI and fMRI. (orig.)

  7. Cardiac CT for planning redo cardiac surgery: effect of knowledge-based iterative model reconstruction on image quality

    International Nuclear Information System (INIS)

    Oda, Seitaro; Weissman, Gaby; Weigold, W. Guy; Vembar, Mani

    2015-01-01

    The purpose of this study was to investigate the effects of knowledge-based iterative model reconstruction (IMR) on image quality in cardiac CT performed for the planning of redo cardiac surgery by comparing IMR images with images reconstructed with filtered back-projection (FBP) and hybrid iterative reconstruction (HIR). We studied 31 patients (23 men, 8 women; mean age 65.1 ± 16.5 years) referred for redo cardiac surgery who underwent cardiac CT. Paired image sets were created using three types of reconstruction: FBP, HIR, and IMR. Quantitative parameters including CT attenuation, image noise, and contrast-to-noise ratio (CNR) of each cardiovascular structure were calculated. The visual image quality - graininess, streak artefact, margin sharpness of each cardiovascular structure, and overall image quality - was scored on a five-point scale. The mean image noise of FBP, HIR, and IMR images was 58.3 ± 26.7, 36.0 ± 12.5, and 14.2 ± 5.5 HU, respectively; there were significant differences in all comparison combinations among the three methods. The CNR of IMR images was better than that of FBP and HIR images in all evaluated structures. The visual scores were significantly higher for IMR than for the other images in all evaluated parameters. IMR can provide significantly improved qualitative and quantitative image quality at in cardiac CT for planning of reoperative cardiac surgery. (orig.)

  8. A Novel Kernel-Based Regularization Technique for PET Image Reconstruction

    Directory of Open Access Journals (Sweden)

    Abdelwahhab Boudjelal

    2017-06-01

    Full Text Available Positron emission tomography (PET is an imaging technique that generates 3D detail of physiological processes at the cellular level. The technique requires a radioactive tracer, which decays and releases a positron that collides with an electron; consequently, annihilation photons are emitted, which can be measured. The purpose of PET is to use the measurement of photons to reconstruct the distribution of radioisotopes in the body. Currently, PET is undergoing a revamp, with advancements in data measurement instruments and the computing methods used to create the images. These computer methods are required to solve the inverse problem of “image reconstruction from projection”. This paper proposes a novel kernel-based regularization technique for maximum-likelihood expectation-maximization ( κ -MLEM to reconstruct the image. Compared to standard MLEM, the proposed algorithm is more robust and is more effective in removing background noise, whilst preserving the edges; this suppresses image artifacts, such as out-of-focus slice blur.

  9. Multiparametric and molecular imaging of breast tumors with MRI and PET/MRI

    International Nuclear Information System (INIS)

    Pinker, K.; Marino, M.A.; Meyer-Baese, A.; Helbich, T.H.

    2016-01-01

    Magnetic resonance imaging (MRI) of the breast is an indispensable tool in breast imaging for many indications. Several functional parameters with MRI and positron emission tomography (PET) have been assessed for imaging of breast tumors and their combined application is defined as multiparametric imaging. Available data suggest that multiparametric imaging using different functional MRI and PET parameters can provide detailed information about the hallmarks of cancer and may provide additional specificity. Multiparametric and molecular imaging of the breast comprises established MRI parameters, such as dynamic contrast-enhanced MRI, diffusion-weighted imaging (DWI), MR proton spectroscopy ( 1 H-MRSI) as well as combinations of radiological and MRI techniques (e.g. PET/CT and PET/MRI) using radiotracers, such as fluorodeoxyglucose (FDG). Multiparametric and molecular imaging of the breast can be performed at different field-strengths (range 1.5-7 T). Emerging parameters comprise novel promising techniques, such as sodium imaging ( 23 Na MRI), phosphorus spectroscopy ( 31 P-MRSI), chemical exchange saturation transfer (CEST) imaging, blood oxygen level-dependent (BOLD) and hyperpolarized MRI as well as various specific radiotracers. Multiparametric and molecular imaging has multiple applications in breast imaging. Multiparametric and molecular imaging of the breast is an evolving field that will enable improved detection, characterization, staging and monitoring for personalized medicine in breast cancer. (orig.) [de

  10. {sup 68}Ga-PSMA-HBED-CC PET imaging in breast carcinoma patients

    Energy Technology Data Exchange (ETDEWEB)

    Sathekge, Mike; Lengana, Thabo; Modiselle, Moshe; Vorster, Mariza; Zeevaart, JanRijn; Ebenhan, Thomas [University of Pretoria and Steve Biko Academic Hospital, Department of Nuclear Medicine, Pretoria (South Africa); Maes, Alex [University of Pretoria and Steve Biko Academic Hospital, Department of Nuclear Medicine, Pretoria (South Africa); AZ Groeninge, Department of Nuclear Medicine, Kortrijk (Belgium); Wiele, Christophe van de [University of Pretoria and Steve Biko Academic Hospital, Department of Nuclear Medicine, Pretoria (South Africa); University Ghent, Department of Radiology and Nuclear Medicine, Ghent (Belgium)

    2017-04-15

    To report on imaging findings using {sup 68}Ga-PSMA-HBED-CC PET in a series of 19 breast carcinoma patients. {sup 68}Ga-PSMA-HBED-CC PET imaging results obtained were compared to routinely performed staging examinations and analyzed as to lesion location and progesterone receptor status. Out of 81 tumor lesions identified, 84% were identified on {sup 68}Ga-PSMA-HBED-CC PET. {sup 68}Ga-PSMA-HBED-CC SUVmean values of distant metastases proved significantly higher (mean, 6.86, SD, 5.68) when compared to those of primary or local recurrences (mean, 2.45, SD, 2.55, p = 0.04) or involved lymph nodes (mean, 3.18, SD, 1.79, p = 0.011). SUVmean values of progesterone receptor-positive lesions proved not significantly different from progesterone receptor-negative lesions. SUV values derived from FDG PET/CT, available in seven patients, and {sup 68}Ga-PSMA-HBED-CC PET/CT imaging proved weakly correlated (r = 0.407, p = 0.015). {sup 68}Ga-PSMA-HBED-CC PET/CT imaging in breast carcinoma confirms the reported considerable variation of PSMA expression on human solid tumors using immunohistochemistry. (orig.)

  11. Biodistribution and PET imaging of [18F]-fluoroadenosine derivatives

    International Nuclear Information System (INIS)

    Alauddin, Mian M.; Shahinian, Antranik; Park, Ryan; Tohme, Michael; Fissekis, John D.; Conti, Peter S.

    2007-01-01

    Introduction: Many fluorinated analogues of adenosine nucleoside have been synthesized and studied as potential antitumor and antiviral agents. Earlier, we reported radiosynthesis of 2'-deoxy-2'-[ 18 F]fluoro-1-β-D-arabinofuranosyl-adenine ([ 18 F]-FAA) and 3'-deoxy-3'-[ 18 F]fluoro-1-β-D-xylofuranosyl-adenine ([ 18 F]FXA). Now, we report their in vivo studies including blood clearance, biodistribution and micro-PET imaging in tumor-bearing nude mice. Methods: Tumors were grown in 6-week-old athymic nude mice (Harlan, Indianapolis, IN, USA) by inoculation of HT-29 cells, wild-type cells in the left flank and transduced cells with HSV-tk on the right flank. When the tumor was about 1 cm in size, animals were injected with these radiotracers for in vivo studies, including blood clearance, micro-PET imaging and biodistribution. Results: Uptake of [ 18 F]FAA in tumor was 3.3-fold higher than blood, with highest uptake in the spleen. Maximum uptake of [ 18 F]FXA was observed in the heart compared to other organs. There was no tumor uptake of [ 18 F]FXA. Biodistribution results were supported by micro-PET images, which also showed very high uptake of [ 18 F]FAA in spleen and visualization of tumors, and high uptake of [ 18 F]FXA in the heart. Conclusion: These results suggest that [ 18 F]FAA may be useful for tumor imaging, while [ 18 F]FXA may have potential as a heart imaging agent with PET

  12. Patient motion effects on the quantification of regional myocardial blood flow with dynamic PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, Chad R. R. N.; Kemp, Robert A. de, E-mail: RAdeKemp@ottawaheart.ca [Physics Department, Room 3302 Herzberg Laboratories, Carleton University, 1125 Colonel By Drive, Ottawa, Ontario K1S 5B6, Canada and Cardiac Imaging, University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, Ontario K1Y 4W7 (Canada); Klein, Ran [Department of Nuclear Medicine, Ottawa Hospital, Civic Campus, 1053 Carling Avenue, Ottawa, Ontario K1Y 4E9 (Canada); Beanlands, Rob S. [Cardiac Imaging, University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, Ontario K1Y 4W7 (Canada)

    2016-04-15

    Purpose: Patient motion is a common problem during dynamic positron emission tomography (PET) scans for quantification of myocardial blood flow (MBF). The purpose of this study was to quantify the prevalence of body motion in a clinical setting and evaluate with realistic phantoms the effects of motion on blood flow quantification, including CT attenuation correction (CTAC) artifacts that result from PET–CT misalignment. Methods: A cohort of 236 sequential patients was analyzed for patient motion under resting and peak stress conditions by two independent observers. The presence of motion, affected time-frames, and direction of motion was recorded; discrepancy between observers was resolved by consensus review. Based on these results, patient body motion effects on MBF quantification were characterized using the digital NURBS-based cardiac-torso phantom, with characteristic time activity curves (TACs) assigned to the heart wall (myocardium) and blood regions. Simulated projection data were corrected for attenuation and reconstructed using filtered back-projection. All simulations were performed without noise added, and a single CT image was used for attenuation correction and aligned to the early- or late-frame PET images. Results: In the patient cohort, mild motion of 0.5 ± 0.1 cm occurred in 24% and moderate motion of 1.0 ± 0.3 cm occurred in 38% of patients. Motion in the superior/inferior direction accounted for 45% of all detected motion, with 30% in the superior direction. Anterior/posterior motion was predominant (29%) in the posterior direction. Left/right motion occurred in 24% of cases, with similar proportions in the left and right directions. Computer simulation studies indicated that errors in MBF can approach 500% for scans with severe patient motion (up to 2 cm). The largest errors occurred when the heart wall was shifted left toward the adjacent lung region, resulting in a severe undercorrection for attenuation of the heart wall. Simulations

  13. Patient motion effects on the quantification of regional myocardial blood flow with dynamic PET imaging

    International Nuclear Information System (INIS)

    Hunter, Chad R. R. N.; Kemp, Robert A. de; Klein, Ran; Beanlands, Rob S.

    2016-01-01

    Purpose: Patient motion is a common problem during dynamic positron emission tomography (PET) scans for quantification of myocardial blood flow (MBF). The purpose of this study was to quantify the prevalence of body motion in a clinical setting and evaluate with realistic phantoms the effects of motion on blood flow quantification, including CT attenuation correction (CTAC) artifacts that result from PET–CT misalignment. Methods: A cohort of 236 sequential patients was analyzed for patient motion under resting and peak stress conditions by two independent observers. The presence of motion, affected time-frames, and direction of motion was recorded; discrepancy between observers was resolved by consensus review. Based on these results, patient body motion effects on MBF quantification were characterized using the digital NURBS-based cardiac-torso phantom, with characteristic time activity curves (TACs) assigned to the heart wall (myocardium) and blood regions. Simulated projection data were corrected for attenuation and reconstructed using filtered back-projection. All simulations were performed without noise added, and a single CT image was used for attenuation correction and aligned to the early- or late-frame PET images. Results: In the patient cohort, mild motion of 0.5 ± 0.1 cm occurred in 24% and moderate motion of 1.0 ± 0.3 cm occurred in 38% of patients. Motion in the superior/inferior direction accounted for 45% of all detected motion, with 30% in the superior direction. Anterior/posterior motion was predominant (29%) in the posterior direction. Left/right motion occurred in 24% of cases, with similar proportions in the left and right directions. Computer simulation studies indicated that errors in MBF can approach 500% for scans with severe patient motion (up to 2 cm). The largest errors occurred when the heart wall was shifted left toward the adjacent lung region, resulting in a severe undercorrection for attenuation of the heart wall. Simulations

  14. Effect of MR contrast agents on quantitative accuracy of PET in combined whole-body PET/MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lois, Cristina [University of Santiago de Compostela, Department of Particle Physics, Santiago de Compostela (Spain); Health Research Institute of Santiago de Compostela (IDIS), Santiago de Compostela (Spain); Imaging Science Institute, Tuebingen (Germany); Bezrukov, Ilja [Eberhard Karls University, Laboratory for Preclinical Imaging and Imaging Technology of the Werner Siemens Foundation, Department of Preclinical Imaging and Radiopharmacy, Tuebingen (Germany); Max Plank Institute for Intelligent Systems, Department of Empirical Inference, Tuebingen (Germany); Schmidt, Holger [Eberhard Karls University, Laboratory for Preclinical Imaging and Imaging Technology of the Werner Siemens Foundation, Department of Preclinical Imaging and Radiopharmacy, Tuebingen (Germany); Eberhard Karls University, Diagnostic and Interventional Radiology, Department of Radiology, Tuebingen (Germany); Schwenzer, Nina; Werner, Matthias K. [Eberhard Karls University, Diagnostic and Interventional Radiology, Department of Radiology, Tuebingen (Germany); Kupferschlaeger, Juergen [Eberhard Karls University, Nuclear Medicine, Department of Radiology, Tuebingen (Germany); Beyer, Thomas [Imaging Science Institute, Tuebingen (Germany); cmi-experts GmbH, Zuerich (Switzerland)

    2012-11-15

    Clinical PET/MR acquisition protocols entail the use of MR contrast agents (MRCA) that could potentially affect PET quantification following MR-based attenuation correction (AC). We assessed the effect of oral and intravenous (IV) MRCA on PET quantification in PET/MR imaging. We employed two MRCA: Lumirem {sup registered} (oral) and Gadovist {sup registered} (IV). First, we determined their reference PET attenuation values using a PET transmission scan (ECAT-EXACT HR+, Siemens) and a CT scan (PET/CT Biograph 16 HI-REZ, Siemens). Second, we evaluated the attenuation of PET signals in the presence of MRCA. Phantoms were filled with clinically relevant concentrations of MRCA in a background of water and {sup 18}F-fluoride, and imaged using a PET/CT scanner (Biograph 16 HI-REZ, Siemens) and a PET/MR scanner (Biograph mMR, Siemens). Third, we investigated the effect of clinically relevant volumes of MRCA on MR-based AC using human pilot data: a patient study employing Gadovist {sup registered} (IV) and a volunteer study employing two different oral MRCA (Lumirem {sup registered} and pineapple juice). MR-based attenuation maps were calculated following Dixon-based fat-water segmentation and an external atlas-based and pattern recognition (AT and PR) algorithm. IV and oral MRCA in clinically relevant concentrations were found to have PET attenuation values similar to those of water. The phantom experiments showed that under clinical conditions IV and oral MRCA did not yield additional attenuation of PET emission signals. Patient scans showed that PET attenuation maps are not biased after the administration of IV MRCA but may be biased, however, after ingestion of iron oxide-based oral MRCA when segmentation-based AC algorithms are used. Alternative AC algorithms, such as AT and PR, or alternative oral contrast agents, such as pineapple juice, can yield unbiased attenuation maps. In clinical PET/MR scenarios MRCA are not expected to lead to markedly increased attenuation

  15. A Survey of FDG- and Amyloid-PET Imaging in Dementia and GRADE Analysis

    Directory of Open Access Journals (Sweden)

    Perani Daniela

    2014-01-01

    Full Text Available PET based tools can improve the early diagnosis of Alzheimer’s disease (AD and differential diagnosis of dementia. The importance of identifying individuals at risk of developing dementia among people with subjective cognitive complaints or mild cognitive impairment has clinical, social, and therapeutic implications. Within the two major classes of AD biomarkers currently identified, that is, markers of pathology and neurodegeneration, amyloid- and FDG-PET imaging represent decisive tools for their measurement. As a consequence, the PET tools have been recognized to be of crucial value in the recent guidelines for the early diagnosis of AD and other dementia conditions. The references based recommendations, however, include large PET imaging literature based on visual methods that greatly reduces sensitivity and specificity and lacks a clear cut-off between normal and pathological findings. PET imaging can be assessed using parametric or voxel-wise analyses by comparing the subject’s scan with a normative data set, significantly increasing the diagnostic accuracy. This paper is a survey of the relevant literature on FDG and amyloid-PET imaging aimed at providing the value of quantification for the early and differential diagnosis of AD. This allowed a meta-analysis and GRADE analysis revealing high values for PET imaging that might be useful in considering recommendations.

  16. Myocardial perfusion of infarcted and normal myocardium in propofol-anesthetized minipigs using 82Rubidium PET

    DEFF Research Database (Denmark)

    Rasmussen, Thomas; Larsen, Bjarke Follin; Kastrup, Jens

    2016-01-01

    Cardiac Rubidium-82 (82Rb) positron-emission-tomography (PET) is a good method for quantification of myocardial blood flow in man. Quantification of myocardial blood flow in animals to evaluate new treatment strategies or to understand underlying disease is also of great interest but raises some...... challenges. Animals, which have been anesthetized during PET acquisition, might react differently to used stress medications, and therefore difficulties might exist while evaluating the resulting PET images using standard software packages from commercial vendors optimized for human hearts. Furthermore...... propofol, used for anesthesia, can influence myocardial perfusion and coronary flow reserve due to its vasorelaxant effect, and interactions might exist between propofol and used stress agents, potentially affecting the result of the examination. We present cardiac 82Rb-PET studies performed in propofol...

  17. PET imaging of the autonomic nervous system

    International Nuclear Information System (INIS)

    THACKERAY, James T.; BENGEL, Frank M.

    2016-01-01

    The autonomic nervous system is the primary extrinsic control of heart rate and contractility, and is subject to adaptive and maladaptive changes in cardiovascular disease. Consequently, noninvasive assessment of neuronal activity and function is an attractive target for molecular imaging. A myriad of targeted radiotracers have been developed over the last 25 years for imaging various components of the sympathetic and parasympathetic signal cascades. While routine clinical use remains somewhat limited, a number of larger scale studies in recent years have supplied momentum to molecular imaging of autonomic signaling. Specifically, the findings of the ADMIRE HF trial directly led to United States Food and Drug Administration approval of 123I-metaiodobenzylguanidine (MIBG) for Single Photon Emission Computed Tomography (SPECT) assessment of sympathetic neuronal innervation, and comparable results have been reported using the analogous PET agent 11C-meta-hydroxyephedrine (HED). Due to the inherent capacity for dynamic quantification and higher spatial resolution, regional analysis may be better served by PET. In addition, preliminary clinical and extensive preclinical experience has provided a broad foundation of cardiovascular applications for PET imaging of the autonomic nervous system. Recent years have witnessed the growth of novel quantification techniques, expansion of multiple tracer studies, and improved understanding of the uptake of different radiotracers, such that the transitional biology of dysfunctional subcellular catecholamine handling can be distinguished from complete denervation. As a result, sympathetic neuronal molecular imaging is poised to play a role in individualized patient care, by stratifying cardiovascular risk, visualizing underlying biology, and guiding and monitoring therapy.

  18. Accuracy verification of PET-CT image fusion and its utilization in target delineation of radiotherapy

    International Nuclear Information System (INIS)

    Wang Xuetao; Yu Jinming; Yang Guoren; Gong Heyi

    2005-01-01

    Objective: Evaluate the accuracy of co-registration of PET and CT (PET-CT) images on line with phantom, and utilize it on patients to provide clinical evidence for target delineation in radiotherapy. Methods: A phantom with markers and different volume cylinders was infused with various concentrations of 18 FDG, and scanned at 4 mm by PET and CT respectively. After having been transmitted into GE eNTEGRA and treatment planning system (TPS) workstations, the images were fused and reconstructed. The distance between the markers and the errors were monitored in PET and CT images respectively. The volume of cylinder in PET and CT images were measured and compared by certain pixel value proportion deduction method. The same procedure was performed on the pulmonary tumor image in ten patients. Results: eNTEGRA and TPS workstations had a good length linearity, but the fusion error of the latter was markedly greater than the former. Tumors in different volume filled by varying concentrations of 18 FDG required different pixel deduction proportion. The cylinder volume of PET and CT images were almost the same, so were the images of pulmonary tumor of ten patients. Conclusions: The accuracy of image co-registration of PET-CT on line may fulfill the clinical demand. Pixel value proportion deduction method can be used for target delineation on PET image. (authors)

  19. Hybrid imaging for detection of carcinoma of unknown primary: A preliminary comparison trial of whole-body PET/MRI versus PET/CT

    International Nuclear Information System (INIS)

    Ruhlmann, Verena; Ruhlmann, Marcus; Bellendorf, Alexander; Grueneisen, Johannes; Sawicki, Lino M.; Grafe, Hong; Forsting, Michael; Bockisch, Andreas; Umutlu, Lale

    2016-01-01

    Highlights: • Both 18F-FDG PET/CT and 18F-FDG PET/MRI provide a comparable diagnostic ability for detection of primary cancer and metastases in CUP-syndrome. • Both imaging methods showed comparably high lesion conspicuity and diagnostic confidence (superior assessment of cervical lesions in PET/MRI). • PET/MRI may serve as a powerful alternative, particularly for therapy monitoring or surveillance considering the long-term cumulative dose. - Abstract: Purpose: The aim of this study is to evaluate and compare the diagnostic potential of integrated whole-body [18F]FDG-PET/MRI to [18F]FDG-PET/CT for detection of a potential primary cancer and metastases in patients suspected for cancer of unknown primary (CUP). Methods: A total of 20 patients (15 male, 5 female, age 53 ± 13 years) suspect for CUP underwent a dedicated head and neck & whole-body [18F]FDG-PET/CT (Biograph mCT 128, Siemens Healthcare) and a subsequent simultaneous [18F]FDG-PET/MRI examination (Biograph mMR, Siemens Healthcare). Two readers rated the datasets (PET/CT; PET/MRI) regarding the detection of the primary cancer and metastases, lesion conspicuity (4-point ordinal scale) and diagnostic confidence (3-point ordinal scale). PET analysis comprised the assessment of maximum standardized uptake values (SUVmax) of all PET-positive lesions using volume of interest (VOI) analysis derived from the PET/CT and PET/MR datasets. All available data considering histology and imaging including prior and clinical follow-up examinations served as reference standard. Statistical analysis included comparison of mean values using Mann-Whitney U test and correlation of SUVmax using Pearson‘s correlation. Results: In 14 out of 20 patients 49 malignant lesions were present. The primary cancer could be correctly identified in 11/20 patients with both PET/CT and PET/MRI. PET/CT enabled the detection of a total 38 metastases, PET/MR respectively of 37 metastases (one lung metastasis <5mm was missed). PET/CT and

  20. Hybrid imaging for detection of carcinoma of unknown primary: A preliminary comparison trial of whole-body PET/MRI versus PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Ruhlmann, Verena; Ruhlmann, Marcus; Bellendorf, Alexander [Department of Nuclear Medicine, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany); Grueneisen, Johannes [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany); Sawicki, Lino M. [Department of Diagnostic and Interventional Radiology, University of Dusseldorf, Moorenstraße 5, 40225 Dusseldorf (Germany); Grafe, Hong [Department of Nuclear Medicine, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany); Forsting, Michael [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany); Bockisch, Andreas [Department of Nuclear Medicine, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany); Umutlu, Lale, E-mail: verena.ruhlmann@uk-essen.de [Department of Nuclear Medicine, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany)

    2016-11-15

    Highlights: • Both 18F-FDG PET/CT and 18F-FDG PET/MRI provide a comparable diagnostic ability for detection of primary cancer and metastases in CUP-syndrome. • Both imaging methods showed comparably high lesion conspicuity and diagnostic confidence (superior assessment of cervical lesions in PET/MRI). • PET/MRI may serve as a powerful alternative, particularly for therapy monitoring or surveillance considering the long-term cumulative dose. - Abstract: Purpose: The aim of this study is to evaluate and compare the diagnostic potential of integrated whole-body [18F]FDG-PET/MRI to [18F]FDG-PET/CT for detection of a potential primary cancer and metastases in patients suspected for cancer of unknown primary (CUP). Methods: A total of 20 patients (15 male, 5 female, age 53 ± 13 years) suspect for CUP underwent a dedicated head and neck & whole-body [18F]FDG-PET/CT (Biograph mCT 128, Siemens Healthcare) and a subsequent simultaneous [18F]FDG-PET/MRI examination (Biograph mMR, Siemens Healthcare). Two readers rated the datasets (PET/CT; PET/MRI) regarding the detection of the primary cancer and metastases, lesion conspicuity (4-point ordinal scale) and diagnostic confidence (3-point ordinal scale). PET analysis comprised the assessment of maximum standardized uptake values (SUVmax) of all PET-positive lesions using volume of interest (VOI) analysis derived from the PET/CT and PET/MR datasets. All available data considering histology and imaging including prior and clinical follow-up examinations served as reference standard. Statistical analysis included comparison of mean values using Mann-Whitney U test and correlation of SUVmax using Pearson‘s correlation. Results: In 14 out of 20 patients 49 malignant lesions were present. The primary cancer could be correctly identified in 11/20 patients with both PET/CT and PET/MRI. PET/CT enabled the detection of a total 38 metastases, PET/MR respectively of 37 metastases (one lung metastasis <5mm was missed). PET/CT and

  1. Dynamic whole-body PET parametric imaging: II. Task-oriented statistical estimation.

    Science.gov (United States)

    Karakatsanis, Nicolas A; Lodge, Martin A; Zhou, Y; Wahl, Richard L; Rahmim, Arman

    2013-10-21

    In the context of oncology, dynamic PET imaging coupled with standard graphical linear analysis has been previously employed to enable quantitative estimation of tracer kinetic parameters of physiological interest at the voxel level, thus, enabling quantitative PET parametric imaging. However, dynamic PET acquisition protocols have been confined to the limited axial field-of-view (~15-20 cm) of a single-bed position and have not been translated to the whole-body clinical imaging domain. On the contrary, standardized uptake value (SUV) PET imaging, considered as the routine approach in clinical oncology, commonly involves multi-bed acquisitions, but is performed statically, thus not allowing for dynamic tracking of the tracer distribution. Here, we pursue a transition to dynamic whole-body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. In a companion study, we presented a novel clinically feasible dynamic (4D) multi-bed PET acquisition protocol as well as the concept of whole-body PET parametric imaging employing Patlak ordinary least squares (OLS) regression to estimate the quantitative parameters of tracer uptake rate Ki and total blood distribution volume V. In the present study, we propose an advanced hybrid linear regression framework, driven by Patlak kinetic voxel correlations, to achieve superior trade-off between contrast-to-noise ratio (CNR) and mean squared error (MSE) than provided by OLS for the final Ki parametric images, enabling task-based performance optimization. Overall, whether the observer's task is to detect a tumor or quantitatively assess treatment response, the proposed statistical estimation framework can be adapted to satisfy the specific task performance criteria, by adjusting the Patlak correlation-coefficient (WR) reference value. The multi-bed dynamic acquisition protocol, as optimized in the preceding companion study

  2. Dynamic whole-body PET parametric imaging: II. Task-oriented statistical estimation

    International Nuclear Information System (INIS)

    Karakatsanis, Nicolas A; Lodge, Martin A; Zhou, Y; Wahl, Richard L; Rahmim, Arman

    2013-01-01

    In the context of oncology, dynamic PET imaging coupled with standard graphical linear analysis has been previously employed to enable quantitative estimation of tracer kinetic parameters of physiological interest at the voxel level, thus, enabling quantitative PET parametric imaging. However, dynamic PET acquisition protocols have been confined to the limited axial field-of-view (∼15–20 cm) of a single-bed position and have not been translated to the whole-body clinical imaging domain. On the contrary, standardized uptake value (SUV) PET imaging, considered as the routine approach in clinical oncology, commonly involves multi-bed acquisitions, but is performed statically, thus not allowing for dynamic tracking of the tracer distribution. Here, we pursue a transition to dynamic whole-body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. In a companion study, we presented a novel clinically feasible dynamic (4D) multi-bed PET acquisition protocol as well as the concept of whole-body PET parametric imaging employing Patlak ordinary least squares (OLS) regression to estimate the quantitative parameters of tracer uptake rate K i and total blood distribution volume V. In the present study, we propose an advanced hybrid linear regression framework, driven by Patlak kinetic voxel correlations, to achieve superior trade-off between contrast-to-noise ratio (CNR) and mean squared error (MSE) than provided by OLS for the final K i parametric images, enabling task-based performance optimization. Overall, whether the observer's task is to detect a tumor or quantitatively assess treatment response, the proposed statistical estimation framework can be adapted to satisfy the specific task performance criteria, by adjusting the Patlak correlation-coefficient (WR) reference value. The multi-bed dynamic acquisition protocol, as optimized in the preceding companion

  3. jQC-PET, an ImageJ macro to analyse the quality control of a PET/CT; jQC-PET, una macro de ImageJ para el analisis del control de calidad de un PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Cortes-Rodicio, J.; Sanchez-Merino, G.; Garcia-Fidalgo, A.

    2015-07-01

    An ImageJ macro has been developed to facilitate the analysis of three PET/CT quality control procedures included in the documents from the National Electrical Manufacturers Association (NU2-2007) and the International Atomic Energy Agency (Pub-1393): image quality, uniformity and spatial resolution. In them, the generation of the regions of interest and the analysis are automatized. The results obtained with the software have been compared with those of the commercial software and the literature. The use of jQC-PET allows a standard analysis and the independence of the commercial software. (Author)

  4. Comparison of Imaging Characteristics of 124I PET for Determination of Optimal Energy Window on the Siemens Inveon PET

    Directory of Open Access Journals (Sweden)

    A Ram Yu

    2016-01-01

    Full Text Available Purpose.124I has a half-life of 4.2 days, which makes it suitable for imaging over several days over its uptake and washout phases. However, it has a low positron branching ratio (23%, because of prompt gamma coincidence due to high-energy γ-photons (602 to 1,691 keV, which are emitted in cascade with positrons. Methods. In this study, we investigated the optimal PET energy window for 124I PET based on image characteristics of reconstructed PET. Image characteristics such as nonuniformities, recovery coefficients (RCs, and the spillover ratios (SORs of 124I were measured as described in NEMA NU 4-2008 standards. Results. The maximum and minimum prompt gamma coincidence fraction (PGF were 33% and 2% in 350~800 and 400~590 keV, respectively. The difference between best and worst uniformity in the various energy windows was less than 1%. The lowest SORs of 124I were obtained at 350~750 keV in nonradioactive water compartment. Conclusion. Optimal energy window should be determined based on image characteristics. Our developed correction method would be useful for the correction of high-energy prompt gamma photon in 124I PET. In terms of the image quality of 124I PET, our findings indicate that an energy window of 350~750 keV would be optimal.

  5. Analysis of PET hypoxia imaging in the quantitative imaging for personalized cancer medicine program

    International Nuclear Information System (INIS)

    Yeung, Ivan; Driscoll, Brandon; Keller, Harald; Shek, Tina; Jaffray, David; Hedley, David

    2014-01-01

    Quantitative imaging is an important tool in clinical trials of testing novel agents and strategies for cancer treatment. The Quantitative Imaging Personalized Cancer Medicine Program (QIPCM) provides clinicians and researchers participating in multi-center clinical trials with a central repository for their imaging data. In addition, a set of tools provide standards of practice (SOP) in end-to-end quality assurance of scanners and image analysis. The four components for data archiving and analysis are the Clinical Trials Patient Database, the Clinical Trials PACS, the data analysis engine(s) and the high-speed networks that connect them. The program provides a suite of software which is able to perform RECIST, dynamic MRI, CT and PET analysis. The imaging data can be assessed securely from remote and analyzed by researchers with these software tools, or with tools provided by the users and installed at the server. Alternatively, QIPCM provides a service for data analysis on the imaging data according developed SOP. An example of a clinical study in which patients with unresectable pancreatic adenocarcinoma were studied with dynamic PET-FAZA for hypoxia measurement will be discussed. We successfully quantified the degree of hypoxia as well as tumor perfusion in a group of 20 patients in terms of SUV and hypoxic fraction. It was found that there is no correlation between bulk tumor perfusion and hypoxia status in this cohort. QIPCM also provides end-to-end QA testing of scanners used in multi-center clinical trials. Based on quality assurance data from multiple CT-PET scanners, we concluded that quality control of imaging was vital in the success in multi-center trials as different imaging and reconstruction parameters in PET imaging could lead to very different results in hypoxia imaging. (author)

  6. Transmission-less attenuation estimation from time-of-flight PET histo-images using consistency equations

    Science.gov (United States)

    Li, Yusheng; Defrise, Michel; Metzler, Scott D.; Matej, Samuel

    2015-08-01

    In positron emission tomography (PET) imaging, attenuation correction with accurate attenuation estimation is crucial for quantitative patient studies. Recent research showed that the attenuation sinogram can be determined up to a scaling constant utilizing the time-of-flight information. The TOF-PET data can be naturally and efficiently stored in a histo-image without information loss, and the radioactive tracer distribution can be efficiently reconstructed using the DIRECT approaches. In this paper, we explore transmission-less attenuation estimation from TOF-PET histo-images. We first present the TOF-PET histo-image formation and the consistency equations in the histo-image parameterization, then we derive a least-squares solution for estimating the directional derivatives of the attenuation factors from the measured emission histo-images. Finally, we present a fast solver to estimate the attenuation factors from their directional derivatives using the discrete sine transform and fast Fourier transform while considering the boundary conditions. We find that the attenuation histo-images can be uniquely determined from the TOF-PET histo-images by considering boundary conditions. Since the estimate of the attenuation directional derivatives can be inaccurate for LORs tangent to the patient boundary, external sources, e.g. a ring or annulus source, might be needed to give an accurate estimate of the attenuation gradient for such LORs. The attenuation estimation from TOF-PET emission histo-images is demonstrated using simulated 2D TOF-PET data.

  7. Twelve automated thresholding methods for segmentation of PET images: a phantom study

    International Nuclear Information System (INIS)

    Prieto, Elena; Peñuelas, Iván; Martí-Climent, Josep M; Lecumberri, Pablo; Gómez, Marisol; Pagola, Miguel; Bilbao, Izaskun; Ecay, Margarita

    2012-01-01

    Tumor volume delineation over positron emission tomography (PET) images is of great interest for proper diagnosis and therapy planning. However, standard segmentation techniques (manual or semi-automated) are operator dependent and time consuming while fully automated procedures are cumbersome or require complex mathematical development. The aim of this study was to segment PET images in a fully automated way by implementing a set of 12 automated thresholding algorithms, classical in the fields of optical character recognition, tissue engineering or non-destructive testing images in high-tech structures. Automated thresholding algorithms select a specific threshold for each image without any a priori spatial information of the segmented object or any special calibration of the tomograph, as opposed to usual thresholding methods for PET. Spherical 18 F-filled objects of different volumes were acquired on clinical PET/CT and on a small animal PET scanner, with three different signal-to-background ratios. Images were segmented with 12 automatic thresholding algorithms and results were compared with the standard segmentation reference, a threshold at 42% of the maximum uptake. Ridler and Ramesh thresholding algorithms based on clustering and histogram-shape information, respectively, provided better results that the classical 42%-based threshold (p < 0.05). We have herein demonstrated that fully automated thresholding algorithms can provide better results than classical PET segmentation tools. (paper)

  8. MO-FG-207-00: Technological Advances in PET/MR Imaging

    International Nuclear Information System (INIS)

    2015-01-01

    The use of integrated PET/MRI systems in clinical applications can best benefit from understanding their technological advances and limitations. The currently available clinical PET/MRI systems have their own characteristics. Thorough analyses of existing technical data and evaluation of necessary performance metrics for quality assurances could be conducted to optimize application-specific PET/MRI protocols. This Symposium will focus on technical advances and limitations of clinical PET/MRI systems, and how this exciting imaging modality can be utilized in applications that can benefit from both PET and MRI. Learning Objectives: To understand the technological advances of clinical PET/MRI systems To correctly identify clinical applications that can benefit from PET/MRI To understand ongoing work to further improve the current PET/MRI technology Floris Jansen is a GE Healthcare employee

  9. MO-FG-207-00: Technological Advances in PET/MR Imaging

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-06-15

    The use of integrated PET/MRI systems in clinical applications can best benefit from understanding their technological advances and limitations. The currently available clinical PET/MRI systems have their own characteristics. Thorough analyses of existing technical data and evaluation of necessary performance metrics for quality assurances could be conducted to optimize application-specific PET/MRI protocols. This Symposium will focus on technical advances and limitations of clinical PET/MRI systems, and how this exciting imaging modality can be utilized in applications that can benefit from both PET and MRI. Learning Objectives: To understand the technological advances of clinical PET/MRI systems To correctly identify clinical applications that can benefit from PET/MRI To understand ongoing work to further improve the current PET/MRI technology Floris Jansen is a GE Healthcare employee.

  10. Generalized PSF modeling for optimized quantitation in PET imaging.

    Science.gov (United States)

    Ashrafinia, Saeed; Mohy-Ud-Din, Hassan; Karakatsanis, Nicolas A; Jha, Abhinav K; Casey, Michael E; Kadrmas, Dan J; Rahmim, Arman

    2017-06-21

    Point-spread function (PSF) modeling offers the ability to account for resolution degrading phenomena within the PET image generation framework. PSF modeling improves resolution and enhances contrast, but at the same time significantly alters image noise properties and induces edge overshoot effect. Thus, studying the effect of PSF modeling on quantitation task performance can be very important. Frameworks explored in the past involved a dichotomy of PSF versus no-PSF modeling. By contrast, the present work focuses on quantitative performance evaluation of standard uptake value (SUV) PET images, while incorporating a wide spectrum of PSF models, including those that under- and over-estimate the true PSF, for the potential of enhanced quantitation of SUVs. The developed framework first analytically models the true PSF, considering a range of resolution degradation phenomena (including photon non-collinearity, inter-crystal penetration and scattering) as present in data acquisitions with modern commercial PET systems. In the context of oncologic liver FDG PET imaging, we generated 200 noisy datasets per image-set (with clinically realistic noise levels) using an XCAT anthropomorphic phantom with liver tumours of varying sizes. These were subsequently reconstructed using the OS-EM algorithm with varying PSF modelled kernels. We focused on quantitation of both SUV mean and SUV max , including assessment of contrast recovery coefficients, as well as noise-bias characteristics (including both image roughness and coefficient of-variability), for different tumours/iterations/PSF kernels. It was observed that overestimated PSF yielded more accurate contrast recovery for a range of tumours, and typically improved quantitative performance. For a clinically reasonable number of iterations, edge enhancement due to PSF modeling (especially due to over-estimated PSF) was in fact seen to lower SUV mean bias in small tumours. Overall, the results indicate that exactly matched PSF

  11. Imaging performance of a full-ring prototype PET-MRI system based on four-layer DOI-PET detectors integrated with a RF coil

    Energy Technology Data Exchange (ETDEWEB)

    Nishikido, Fumihiko; Tashima, Hideaki [National Institute of Radiological Sciences, Chiba (Japan); Suga, Mikio [Chiba University, Chiba (Japan); Inadama, Naoko; Eiji, Yoshida; Obata, Takayuki; Yamaya, Taiga [National Institute of Radiological Sciences, Chiba (Japan)

    2015-05-18

    We are developing a PET system integrated with a birdcage RF-coil for PET-MRI in order to realize both high sensitivity and high spatial resolution of the PET image by using the 4-layered depth-of-interaction (DOI) PET detector. We constructed a full-ring prototype system and evaluated performances, especially imaging performance, of the prototype system in simultaneous measurement. The prototype system consists of eight four-layer DOI-PET detectors and a prototype birdcage RF-coil developed for the proposed system. The PET detectors consist of six monolithic multi-pixel photon counter array (S11064-050P), a readout circuit, fourlayer DOI scintillator arrays and a shielding box made of 35 μm thick copper foil. The crystal array consists of 2.0 mm x 2.0 mm x 5.0 mm LYSO crystals arranged in 38 x 6 x 4 layer. The RF-coil has eight coil elements and the eight PET detectors are positioned at each element gap. The diameter of the RF-coil elements is 261 mm. We conducted performance tests of the prototype system with a 3.0 T MRI (MAGNETOM Verio). Only the PET detectors, the RF-coil and the cables were in an MRI room during measurements. A data acquisition system and power supplies for the MPPCs and preamplifiers were outside the MRI room and connected to all the detectors through a penetration panel. As a result, the spatial resolutions of a Na-22 point source in the PET image were lower than 1.6 mm in whole the FOV due to the DOI capability. In addition, the influence of the simultaneous measurements on the PET performance is negligible. On the other hand, the SNR of the phantom image in the magnitude images was degraded from 259.7 to 209.4 due to noise contamination from the power supplies.

  12. Imaging performance of a full-ring prototype PET-MRI system based on four-layer DOI-PET detectors integrated with a RF coil

    International Nuclear Information System (INIS)

    Nishikido, Fumihiko; Tashima, Hideaki; Suga, Mikio; Inadama, Naoko; Eiji, Yoshida; Obata, Takayuki; Yamaya, Taiga

    2015-01-01

    We are developing a PET system integrated with a birdcage RF-coil for PET-MRI in order to realize both high sensitivity and high spatial resolution of the PET image by using the 4-layered depth-of-interaction (DOI) PET detector. We constructed a full-ring prototype system and evaluated performances, especially imaging performance, of the prototype system in simultaneous measurement. The prototype system consists of eight four-layer DOI-PET detectors and a prototype birdcage RF-coil developed for the proposed system. The PET detectors consist of six monolithic multi-pixel photon counter array (S11064-050P), a readout circuit, fourlayer DOI scintillator arrays and a shielding box made of 35 μm thick copper foil. The crystal array consists of 2.0 mm x 2.0 mm x 5.0 mm LYSO crystals arranged in 38 x 6 x 4 layer. The RF-coil has eight coil elements and the eight PET detectors are positioned at each element gap. The diameter of the RF-coil elements is 261 mm. We conducted performance tests of the prototype system with a 3.0 T MRI (MAGNETOM Verio). Only the PET detectors, the RF-coil and the cables were in an MRI room during measurements. A data acquisition system and power supplies for the MPPCs and preamplifiers were outside the MRI room and connected to all the detectors through a penetration panel. As a result, the spatial resolutions of a Na-22 point source in the PET image were lower than 1.6 mm in whole the FOV due to the DOI capability. In addition, the influence of the simultaneous measurements on the PET performance is negligible. On the other hand, the SNR of the phantom image in the magnitude images was degraded from 259.7 to 209.4 due to noise contamination from the power supplies.

  13. PET tracers for somatostatin receptor imaging of neuroendocrine tumors

    DEFF Research Database (Denmark)

    Johnbeck, Camilla Bardram; Knigge, Ulrich; Kjær, Andreas

    2014-01-01

    Neuroendocrine tumors have shown rising incidence mainly due to higher clinical awareness and better diagnostic tools over the last 30 years. Functional imaging of neuroendocrine tumors with PET tracers is an evolving field that is continuously refining the affinity of new tracers in the search...... these PET tracers further....

  14. Integration of PET-CT and cone-beam CT for image-guided radiotherapy with high image quality and registration accuracy

    Science.gov (United States)

    Wu, T.-H.; Liang, C.-H.; Wu, J.-K.; Lien, C.-Y.; Yang, B.-H.; Huang, Y.-H.; Lee, J. J. S.

    2009-07-01

    Hybrid positron emission tomography-computed tomography (PET-CT) system enhances better differentiation of tissue uptake of 18F-fluorodeoxyglucose (18F-FDG) and provides much more diagnostic value in the non-small-cell lung cancer and nasopharyngeal carcinoma (NPC). In PET-CT, high quality CT images not only offer diagnostic value on anatomic delineation of the tissues but also shorten the acquisition time for attenuation correction (AC) compared with PET-alone imaging. The linear accelerators equipped with the X-ray cone-beam computed tomography (CBCT) imaging system for image-guided radiotherapy (IGRT) provides excellent verification on position setup error. The purposes of our study were to optimize the CT acquisition protocols of PET-CT and to integrate the PET-CT and CBCT for IGRT. The CT imaging parameters were modified in PET-CT for increasing the image quality in order to enhance the diagnostic value on tumour delineation. Reproducibility and registration accuracy via bone co-registration algorithm between the PET-CT and CBCT were evaluated by using a head phantom to simulate a head and neck treatment condition. Dose measurement in computed tomography dose index (CTDI) was also estimated. Optimization of the CT acquisition protocols of PET-CT was feasible in this study. Co-registration accuracy between CBCT and PET-CT on axial and helical modes was in the range of 1.06 to 2.08 and 0.99 to 2.05 mm, respectively. In our result, it revealed that the accuracy of the co-registration with CBCT on helical mode was more accurate than that on axial mode. Radiation doses in CTDI were 4.76 to 18.5 mGy and 4.83 to 18.79 mGy on axial and helical modes, respectively. Registration between PET-CT and CBCT is a state-of-the-art registration technology which could provide much information on diagnosis and accurate tumour contouring on radiotherapy while implementing radiotherapy procedures. This novelty technology of PET-CT and cone-beam CT integration for IGRT may have a

  15. Integration of PET-CT and cone-beam CT for image-guided radiotherapy with high image quality and registration accuracy

    International Nuclear Information System (INIS)

    Wu, T-H; Liang, C-H; Wu, J-K; Lien, C-Y; Yang, B-H; Lee, J J S; Huang, Y-H

    2009-01-01

    Hybrid positron emission tomography-computed tomography (PET-CT) system enhances better differentiation of tissue uptake of 18 F-fluorodeoxyglucose ( 18 F-FDG) and provides much more diagnostic value in the non-small-cell lung cancer and nasopharyngeal carcinoma (NPC). In PET-CT, high quality CT images not only offer diagnostic value on anatomic delineation of the tissues but also shorten the acquisition time for attenuation correction (AC) compared with PET-alone imaging. The linear accelerators equipped with the X-ray cone-beam computed tomography (CBCT) imaging system for image-guided radiotherapy (IGRT) provides excellent verification on position setup error. The purposes of our study were to optimize the CT acquisition protocols of PET-CT and to integrate the PET-CT and CBCT for IGRT. The CT imaging parameters were modified in PET-CT for increasing the image quality in order to enhance the diagnostic value on tumour delineation. Reproducibility and registration accuracy via bone co-registration algorithm between the PET-CT and CBCT were evaluated by using a head phantom to simulate a head and neck treatment condition. Dose measurement in computed tomography dose index (CTDI) was also estimated. Optimization of the CT acquisition protocols of PET-CT was feasible in this study. Co-registration accuracy between CBCT and PET-CT on axial and helical modes was in the range of 1.06 to 2.08 and 0.99 to 2.05 mm, respectively. In our result, it revealed that the accuracy of the co-registration with CBCT on helical mode was more accurate than that on axial mode. Radiation doses in CTDI were 4.76 to 18.5 mGy and 4.83 to 18.79 mGy on axial and helical modes, respectively. Registration between PET-CT and CBCT is a state-of-the-art registration technology which could provide much information on diagnosis and accurate tumour contouring on radiotherapy while implementing radiotherapy procedures. This novelty technology of PET-CT and cone-beam CT integration for IGRT may have a

  16. The establishment of the method of three dimension volumetric fusion of emission and transmission images for PET imaging

    International Nuclear Information System (INIS)

    Zhang Xiangsong; He Zuoxiang

    2004-01-01

    Objective: To establish the method of three dimension volumetric fusion of emission and transmission images for PET imaging. Methods: The volume data of emission and transmission images acquired with Siemens ECAT HR + PET scanner were transferred to PC computer by local area network. The PET volume data were converted into 8 bit byte type, and scaled to the range of 0-255. The data coordinates of emission and transmission images were normalized by three-dimensional coordinate conversion in the same way. The images were fused with the mode of alpha-blending. The accuracy of image fusion was confirmed by its clinical application in 13 cases. Results: The three dimension volumetric fusion of emission and transmission images clearly displayed the silhouette and anatomic configuration in chest, including chest wall, lung, heart, mediastinum, et al. Forty-eight lesions in chest in 13 cases were accurately located by the image fusion. Conclusions: The volume data of emission and transmission images acquired with Siemens ECAT HR + PET scanner have the same data coordinate. The three dimension fusion software can conveniently used for the three dimension volumetric fusion of emission and transmission images, and also can correctly locate the lesions in chest

  17. Measurement of cardiovascular function using a novel view-sharing PET reconstruction method and tracer kinetic analysis

    Directory of Open Access Journals (Sweden)

    Paul R. Territo

    2016-10-01

    Full Text Available Abstract Recent advancements in PET instrumentation have made the non-invasive assessment of cardiovascular function in small animals a reality. The majority of small animal PET systems use stationary detector gantries, thus affording high temporal resolution imaging of cardiac function. Systems designed to maximize spatial resolution and detection sensitivity employing rotating gantry designs are suboptimal when high temporal resolution imaging is needed. To overcome this limitation, the current work developed a novel view-sharing data analysis scheme suitable for dynamic cardiac PET imaging using 18F-NaF as the tracer and tracer kinetic model analysis. This scheme was tested in a rat model of cardiovascular function where the relationship between direct transonic flow measures of cardiac output were highly correlated (f(x = 1.0216x − 24.233, R = 0.9158, p < 0.001 with the new model. Similarly, derived measures of stroke volume were also highly correlated (f(x = 0.9655x − 0.0428, R = 0.9453, p < 0.001 with the current approach. Administration of xylazine caused a statistically significant increase in stroke volume (0.32 ± 0.07 ml, p = 0.003, n = 4 and a significant decrease in both heart rate (−155 ± 7.1 beats/min, p < 0.001, n = 4 and cardiac output (−75.9 ± 23.0 ml/kg min, p = 0.01, n = 4. These findings suggest that the new sinogram binning and kinetic modeling methods produce reliable cardiac function measures suitable for longitudinal monitoring of cardiovascular function.

  18. Myocardial blood flow quantification by Rb-82 cardiac PET/CT: A detailed reproducibility study between two semi-automatic analysis programs.

    OpenAIRE

    Dunet, V.; Klein, R.; Allenbach, G.; Renaud, J.; deKemp, R.A.; Prior, J.O.

    2016-01-01

    Background Several analysis software packages for myocardial blood flow (MBF) quantification from cardiac PET studies exist, but they have not been compared using concordance analysis, which can characterize precision and bias separately. Reproducible measurements are needed for quantification to fully develop its clinical potential. Methods Fifty-one patients underwent dynamic Rb-82 PET at rest and during adenosine stress. Data were processed with PMOD and FlowQuant (Lortie model). MBF and m...

  19. Diagnostic imaging of exotic pets

    International Nuclear Information System (INIS)

    Silverman, S.

    1993-01-01

    Radiographic, ultrasonographic, and computed tomographic (CT) imaging are important diagnostic modalities in exotic pets. The use of appropriate radiographic equipment, film-screen combinations, and radiographic projections enhances the information obtained from radiographs. Both normal findings and common radiographic abnormalities are discussed. The use of ultrasonography and CT scanning for exotic small mammals and reptiles is described

  20. Motion-corrected whole-heart PET-MR for the simultaneous visualisation of coronary artery integrity and myocardial viability: an initial clinical validation.

    Science.gov (United States)

    Munoz, Camila; Kunze, Karl P; Neji, Radhouene; Vitadello, Teresa; Rischpler, Christoph; Botnar, René M; Nekolla, Stephan G; Prieto, Claudia

    2018-05-12

    Cardiac PET-MR has shown potential for the comprehensive assessment of coronary heart disease. However, image degradation due to physiological motion remains a challenge that could hinder the adoption of this technology in clinical practice. The purpose of this study was to validate a recently proposed respiratory motion-corrected PET-MR framework for the simultaneous visualisation of myocardial viability ( 18 F-FDG PET) and coronary artery anatomy (coronary MR angiography, CMRA) in patients with chronic total occlusion (CTO). A cohort of 14 patients was scanned with the proposed PET-CMRA framework. PET and CMRA images were reconstructed with and without the proposed motion correction approach for comparison purposes. Metrics of image quality including visible vessel length and sharpness were obtained for CMRA for both the right and left anterior descending coronary arteries (RCA, LAD), and relative increase in 18 F-FDG PET signal after motion correction for standard 17-segment polar maps was computed. Resulting coronary anatomy by CMRA and myocardial integrity by PET were visually compared against X-ray angiography and conventional Late Gadolinium Enhancement (LGE) MRI, respectively. Motion correction increased CMRA visible vessel length by 49.9% and 32.6% (RCA, LAD) and vessel sharpness by 12.3% and 18.9% (RCA, LAD) on average compared to uncorrected images. Coronary lumen delineation on motion-corrected CMRA images was in good agreement with X-ray angiography findings. For PET, motion correction resulted in an average 8% increase in 18 F-FDG signal in the inferior and inferolateral segments of the myocardial wall. An improved delineation of myocardial viability defects and reduced noise in the 18 F-FDG PET images was observed, improving correspondence to subendocardial LGE-MRI findings compared to uncorrected images. The feasibility of the PET-CMRA framework for simultaneous cardiac PET-MR imaging in a short and predictable scan time (~11 min) has been

  1. Positron emission tomographic imaging of cardiac sympathetic innervation and function

    International Nuclear Information System (INIS)

    Goldstein, D.S.; Chang, P.C.; Eisenhofer, G.; Miletich, R.; Finn, R.; Bacher, J.; Kirk, K.L.; Bacharach, S.; Kopin, I.J.

    1990-01-01

    Sites of uptake, storage, and metabolism of [ 18 F]fluorodopamine and excretion of [ 18 F]fluorodopamine and its metabolites were visualized using positron emission tomographic (PET) scanning after intravenous injection of the tracer into anesthetized dogs. Radioactivity was concentrated in the renal pelvis, heart, liver, spleen, salivary glands, and gall bladder. Uptake of 18F by the heart resulted in striking delineation of the left ventricular myocardium. Pretreatment with desipramine markedly decreased cardiac positron emission, consistent with dependence of the heart on neuronal uptake (uptake-1) for removal of circulating catecholamines. In reserpinized animals, cardiac positron emission was absent within 30 minutes after injection of [ 18 F]-6-fluorodopamine, demonstrating that the emission in untreated animals was from radioactive labeling of the sympathetic storage vesicles. Decreased positron emission from denervated salivary glands confirmed that the tracer was concentrated in sympathetic neurons. Radioactivity in the gall bladder and urinary system depicted the hepatic and renal excretion of the tracer and its metabolites. Administration of tyramine or nitroprusside increased and ganglionic blockade with trimethaphan decreased the rate of loss of myocardial radioactivity. The results show that PET scanning after administration of [ 18 F]fluorodopamine can be used to visualize sites of sympathetic innervation, follow the metabolism and renal and hepatic excretion of catecholamines, and examine cardiac sympathetic function

  2. Some views about PET technique establish and development

    International Nuclear Information System (INIS)

    Huang Zuhan

    2001-01-01

    About 2100 patients had been performed in Nanfang PET center since its establish in November, 1999. The clinical practice showed that the positron emission tomography (PET) had unique value for the diagnosis of malignancy, cardiac coronal artery disease, myocardium viability and for lesion localization of epilepsy and other cerebral function diseases. It had important impact to treatment of these diseases and improved the treatment outcomes of them. It also promoted the scientific studies and other correlative subjects and enhanced the station of nuclear medicine. Its integrative benefit was very great. In order to develop this technique more smoothly, authors would give the views on some questions such as how to look on PET images, its clinical value, its price and its cost-effectiveness. The authors would also give some proposal which could not be neglectable for establish of PET technique

  3. PET for molecular imaging of cancer: a tool for tailored therapy

    International Nuclear Information System (INIS)

    Kjaer, Andreas

    2014-01-01

    The concept of personalised medicine has led to a need for improved phenotyping as well as prediction of treatment response early after therapy initiation. Most of the molecular biology methods used today need tissue sampling for in vitro analysis. In contrast, molecular imaging allows for non-invasive studies at the molecular level in living, intact organisms. Accordingly, molecular imaging with PET has been one of the most successful techniques in such phenotyping and response prediction using FDG. In addition, recent development of new PET tracers has further improved the value of PET in tumor characterization. Such new PET tracers allow for visualization of tumor specific receptors and tissue characteristics such as ability to metastasize. Furthermore, PET has a high sensitivity and allows for quantification and is not prone to sampling error as seen with biopsies. We will present examples of development of probes targeting the somatostatin receptor type 2, over-expressed in neuroendocrine tumors, including our first-in-man studies of 64 Cu-DOTATATE. Also development in probes for visualization of the invasive phenotype will be presented. Finally, with the most recent development of true integrated PET/MRI scanners has now become possible to add information from MRI. The value of such hybrid imaging will also be briefly discussed. (author)

  4. PET for molecular imaging of cancer: a tool for tailored therapy

    International Nuclear Information System (INIS)

    Kjaer, Andreas

    2013-01-01

    The concept of personalised medicine has led to a need for improved phenotyping as well as prediction of treatment response early after therapy initiation. Most of the molecular biology methods used today need tissue sampling for in vitro analysis. In contrast, molecular imaging allows for non-invasive studies at the molecular level in living, intact organisms. Accordingly, molecular imaging with PET has been one of the most successful techniques in such phenotyping and response prediction using FDG. In addition, recent development of new PET tracers has further improved the value of PET in tumor characterization. Such new PET tracers allow for visualization of tumor specific receptors and tissue characteristics such as ability to metastasize. Furthermore, PET has a high sensitivity and allows for quantification and is not prone to sampling error as seen with biopsies. We will present examples of development of probes targeting the somatostatin receptor type 2, over-expressed in neuroendocrine tumors, including our first-in-man studies of 64Cu-DOTATATE. Also development in probes for visualization of the invasive phenotype will be presented. Finally, with the most recent development of true integrated PET/MRI scanners it has now become possible to add information from MRI. The value of such hybrid imaging will also be briefly discussed. (author)

  5. New developments in molecular imaging: positron emission tomography time-of-flight (TOF-PET)

    International Nuclear Information System (INIS)

    Aguilar, P.; Couce, B.; Iglesias, A.; Lois, C.

    2011-01-01

    Positron Emission tomography (PET) in increasingly being used in oncology for the diagnosis and staging of disease, as well as in monitoring response to therapy. One of the last advances in PET is the incorporation of Time-of-Flight (TOF) information, which improves the tomographic reconstruction process and subsequently the quality of the final image. In this work, we explain the principles of PET and the fundamentals of TOF-PET. Clinical images are shown in order to illustrate how TOF-PET improves the detectability of small lesions, particularly in patients with high body mass index. (Author) 20 refs

  6. Imaging of Prostate Cancer Using Urokinase-Type Plasminogen Activator Receptor PET

    DEFF Research Database (Denmark)

    Skovgaard, Dorthe; Persson, Morten; Kjaer, Andreas

    2017-01-01

    Urokinase-type plasminogen activator receptor (uPAR) overexpression is an important biomarker for aggressiveness in cancer including prostate cancer (PC) and provides independent clinical information in addition to prostate-specific antigen and Gleason score. This article focuses on uPAR PET...... as a new diagnostic and prognostic imaging biomarker in PC. Many preclinical uPAR-targeted PET imaging studies using AE105 in cancer models have been undertaken with promising results. A major breakthrough was obtained with the recent human translation of uPAR PET in using 64Cu- and 68Ga-labelled versions...

  7. 3.5D dynamic PET image reconstruction incorporating kinetics-based clusters

    International Nuclear Information System (INIS)

    Lu Lijun; Chen Wufan; Karakatsanis, Nicolas A; Rahmim, Arman; Tang Jing

    2012-01-01

    Standard 3D dynamic positron emission tomographic (PET) imaging consists of independent image reconstructions of individual frames followed by application of appropriate kinetic model to the time activity curves at the voxel or region-of-interest (ROI). The emerging field of 4D PET reconstruction, by contrast, seeks to move beyond this scheme and incorporate information from multiple frames within the image reconstruction task. Here we propose a novel reconstruction framework aiming to enhance quantitative accuracy of parametric images via introduction of priors based on voxel kinetics, as generated via clustering of preliminary reconstructed dynamic images to define clustered neighborhoods of voxels with similar kinetics. This is then followed by straightforward maximum a posteriori (MAP) 3D PET reconstruction as applied to individual frames; and as such the method is labeled ‘3.5D’ image reconstruction. The use of cluster-based priors has the advantage of further enhancing quantitative performance in dynamic PET imaging, because: (a) there are typically more voxels in clusters than in conventional local neighborhoods, and (b) neighboring voxels with distinct kinetics are less likely to be clustered together. Using realistic simulated 11 C-raclopride dynamic PET data, the quantitative performance of the proposed method was investigated. Parametric distribution-volume (DV) and DV ratio (DVR) images were estimated from dynamic image reconstructions using (a) maximum-likelihood expectation maximization (MLEM), and MAP reconstructions using (b) the quadratic prior (QP-MAP), (c) the Green prior (GP-MAP) and (d, e) two proposed cluster-based priors (CP-U-MAP and CP-W-MAP), followed by graphical modeling, and were qualitatively and quantitatively compared for 11 ROIs. Overall, the proposed dynamic PET reconstruction methodology resulted in substantial visual as well as quantitative accuracy improvements (in terms of noise versus bias performance) for parametric DV

  8. Nonrigid Image Registration for Head and Neck Cancer Radiotherapy Treatment Planning With PET/CT

    International Nuclear Information System (INIS)

    Ireland, Rob H.; Dyker, Karen E.; Barber, David C.; Wood, Steven M.; Hanney, Michael B.; Tindale, Wendy B.; Woodhouse, Neil; Hoggard, Nigel; Conway, John; Robinson, Martin H.

    2007-01-01

    Purpose: Head and neck radiotherapy planning with positron emission tomography/computed tomography (PET/CT) requires the images to be reliably registered with treatment planning CT. Acquiring PET/CT in treatment position is problematic, and in practice for some patients it may be beneficial to use diagnostic PET/CT for radiotherapy planning. Therefore, the aim of this study was first to quantify the image registration accuracy of PET/CT to radiotherapy CT and, second, to assess whether PET/CT acquired in diagnostic position can be registered to planning CT. Methods and Materials: Positron emission tomography/CT acquired in diagnostic and treatment position for five patients with head and neck cancer was registered to radiotherapy planning CT using both rigid and nonrigid image registration. The root mean squared error for each method was calculated from a set of anatomic landmarks marked by four independent observers. Results: Nonrigid and rigid registration errors for treatment position PET/CT to planning CT were 2.77 ± 0.80 mm and 4.96 ± 2.38 mm, respectively, p = 0.001. Applying the nonrigid registration to diagnostic position PET/CT produced a more accurate match to the planning CT than rigid registration of treatment position PET/CT (3.20 ± 1.22 mm and 4.96 ± 2.38 mm, respectively, p = 0.012). Conclusions: Nonrigid registration provides a more accurate registration of head and neck PET/CT to treatment planning CT than rigid registration. In addition, nonrigid registration of PET/CT acquired with patients in a standardized, diagnostic position can provide images registered to planning CT with greater accuracy than a rigid registration of PET/CT images acquired in treatment position. This may allow greater flexibility in the timing of PET/CT for head and neck cancer patients due to undergo radiotherapy

  9. FDG PET/CT : EANM procedure guidelines for tumour imaging: version 2.0

    NARCIS (Netherlands)

    Boellaard, Ronald; Delgado-Bolton, Roberto; Oyen, Wim J. G.; Giammarile, Francesco; Tatsch, Klaus; Eschner, Wolfgang; Verzijlbergen, Fred J.; Barrington, Sally F.; Pike, Lucy C.; Weber, Wolfgang A.; Stroobants, Sigrid; Delbeke, Dominique; Donohoe, Kevin J.; Holbrook, Scott; Graham, Michael M.; Testanera, Giorgio; Hoekstra, Otto S.; Zijlstra, Josee; Visser, Eric; Hoekstra, Corneline J.; Pruim, Jan; Willemsen, Antoon; Arends, Bertjan; Kotzerke, Joerg; Bockisch, Andreas; Beyer, Thomas; Chiti, Arturo; Krause, Bernd J.

    The purpose of these guidelines is to assist physicians in recommending, performing, interpreting and reporting the results of FDG PET/CT for oncological imaging of adult patients. PET is a quantitative imaging technique and therefore requires a common quality control (QC)/quality assurance (QA)

  10. Late infectious endocarditis of surgical patch closure of atrial septal defects diagnosed by 18F-fluorodeoxyglucose gated cardiac computed tomography (18F-FDG-PET/CT): a case report.

    Science.gov (United States)

    Honnorat, Estelle; Seng, Piseth; Riberi, Alberto; Habib, Gilbert; Stein, Andreas

    2016-08-24

    In contrast to percutaneous atrial septal occluder device, surgical patch closure of atrial defects was known to be no infective endocarditis risk. We herein report the first case of late endocarditis of surgical patch closure of atrial septal defects occurred at 47-year after surgery. On September 2014, a 56-year-old immunocompetent French Caucasian man was admitted into the Emergency Department for 3-week history of headache, acute decrease of psychomotor performance and fever at 40 °C. The diagnosis has been evoked during his admission for the management of a brain abscess and confirmed using 18F-fluorodeoxyglucose gated cardiac computed tomography (18F-FDG-PET/CT). Bacterial cultures of surgical deep samples of brain abscess were positive for Streptococcus intermedius and Aggregatibacter aphrophilus as identified by the matrix-assisted laser desorption/ionization-time of flight (MALDI-TOF) mass spectrometry and confirmed with 16S rRNA gene sequencing. The patient was treated by antibiotics for 8 weeks and surgical patch closure removal. In summary, late endocarditis on surgical patch and on percutaneous atrial septal occluder device of atrial septal defects is rare. Cardiac imaging by the 18F-fluorodeoxyglucose gated cardiac computed tomography (18F-FDG-PET/CT) could improve the diagnosis and care endocarditis on surgical patch closure of atrial septal defects while transthoracic and transesophageal echocardiography remained difficult to interpret.

  11. NUCLEAR IMAGING IN THE DIAGNOSIS OF CARDIAC AMYLOIDOSIS

    Directory of Open Access Journals (Sweden)

    V. B. Sergienko

    2018-01-01

    Full Text Available Histological analysis of endomyocardial tissue is still the gold standard for the diagnosis of cardiac amyloidosis but has its limitations. Accordingly, there is a need for noninvasive techniques to cardiac amyloidosis diagnostics. Echocardiography and magnetic resonance imaging can show characteristics which may not be very specific for cardiac amyloid. Recently, new opportunities of nuclear imaging in risk stratification and assessment of prognosis for patients with cardiac amyloidosis have appeared. During the last two decades different classes of radiopharmaceuticals have been developed based on compounds tropic to the components of amyloid infiltrates. In this paper we describe the current possibilities and perspectives of nuclear medicine techniques in patients with cardiac amyloidosis, including osteotropic and neurotropic scintigraphy, single-photon and positron emission tomography

  12. Quality criteria for cardiac images: An update

    International Nuclear Information System (INIS)

    Bernardi, G.; Bar, O.; Jezewski, T.; Vano, E.; Maccia, C.; Trianni, A.; Padovani, R.

    2008-01-01

    The DIMOND II and III Cardiology Groups have agreed on quality criteria for cardiac images and developed a scoring system, to provide a tool to test quality of coronary angiograms, which was demonstrated to be of value in clinical practice. In the last years, digital flat panel technology has been introduced in cardiac angiographic systems and the radiological technique may have been influenced by the better performance of these new detectors. This advance in digital imaging, together with the lesson learned from previous studies, warranted the revision of the quality criteria for cardiac angiographic images as formerly defined. DIMOND criteria were reassessed to allow a simpler evaluation of angiograms. Clinical criteria were simplified and separated from technical criteria. Furthermore, the characteristics of an optimised angiographic technique have been outlined. (authors)

  13. Real-Time Imaging System for the OpenPET

    Science.gov (United States)

    Tashima, Hideaki; Yoshida, Eiji; Kinouchi, Shoko; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo; Suga, Mikio; Haneishi, Hideaki; Yamaya, Taiga

    2012-02-01

    The OpenPET and its real-time imaging capability have great potential for real-time tumor tracking in medical procedures such as biopsy and radiation therapy. For the real-time imaging system, we intend to use the one-pass list-mode dynamic row-action maximum likelihood algorithm (DRAMA) and implement it using general-purpose computing on graphics processing units (GPGPU) techniques. However, it is difficult to make consistent reconstructions in real-time because the amount of list-mode data acquired in PET scans may be large depending on the level of radioactivity, and the reconstruction speed depends on the amount of the list-mode data. In this study, we developed a system to control the data used in the reconstruction step while retaining quantitative performance. In the proposed system, the data transfer control system limits the event counts to be used in the reconstruction step according to the reconstruction speed, and the reconstructed images are properly intensified by using the ratio of the used counts to the total counts. We implemented the system on a small OpenPET prototype system and evaluated the performance in terms of the real-time tracking ability by displaying reconstructed images in which the intensity was compensated. The intensity of the displayed images correlated properly with the original count rate and a frame rate of 2 frames per second was achieved with average delay time of 2.1 s.

  14. Metallic artifacts caused by dental metal prostheses on PET images. A PET/CT phantom study using different PET/CT scanners

    International Nuclear Information System (INIS)

    Shimamoto, Hiroaki; Kakimoto, Naoya; Murakami, Shumei; Furukawa, Souhei; Fujino, Kouichi; Hamada, Seiki; Shimosegawa, Eku; Hatazawa, Jun

    2009-01-01

    The objective of this study was to investigate the effects of computed tomography (CT) artifacts caused by dental metal prostheses on positron emission tomography (PET) images. A dental arch cast was fixed in a cylindrical water-bath phantom. A spherical phantom positioned in the vicinity of the dental arch cast was used to simulate a tumor. To simulate the tumor imaging, the ratio of the 18 F-fluoro-deoxy-glucose radioactivity concentration of the spherical phantom to that of the water-bath phantom was set at 2.5. A dental bridge composed of a gold-silver-palladium alloy on the right mandibular side was prepared. A spherical phantom was set in the white artifact area on the CT images (site A), in a slightly remote area from the white artifact (site B), and in a black artifact area (site C). A PET/CT scan was performed with and without the metal bridge at each simulated tumor site, and the artifactual influence was evaluated on the axial attenuation-corrected (AC) PET images, in which the simulated tumor produced the strongest accumulation. Measurements were performed using three types of PET/CT scanners (scanners 1 and 2 with CT-based attenuation correction, and 3 with Cesium-137 ( 137 Cs)-based attenuation correction). The influence of the metal bridge was evaluated using the change rate of the SUVmean with and without the metal bridge. At site A, an overestimation was shown (scanner 1: +5.0% and scanner 2: +2.5%), while scanner 3 showed an underestimation of -31.8%. At site B, an overestimation was shown (scanner 1: +2.1% and scanner 2: +2.0%), while scanner 3 showed an underestimation of -2.6%. However, at site C, an underestimation was shown (scanner 1: -25.0%, scanner 2: -32.4%, and scanner 3: -8.4%). When CT is used for attenuation correction in patients with dental metal prostheses, an underestimation of radioactivity of accumulated tracer is anticipated in the dark streak artifact area on the CT images. In this study, the dark streak artifacts of the CT

  15. Metastasis of the gastrointestinal tract. FDG-PET imaging

    International Nuclear Information System (INIS)

    Hayasaka, Kazumasa; Nihashi, Takashi; Matsuura, Toshihiro

    2007-01-01

    We assess the usefulness of F-18-fluoro-deoxy-glucose (FDG) positron emission tomography (PET) in the evaluation of gastrointestinal metastases. Four cases (five lesions) in which metastases from three lung cancers and one malignant fibrous histiocytoma (MFH) of the femur were found in the gastrointestinal tract were reviewed (men/women 3:1, age 63-78 years, mean 72 years). The five lesions were duodenal, jejunal metastasis, and two stomach metastases from lung carcinoma, and rectal metastasis from MFH of the femur. FDG-PET was unable to detect small masses, but it was able to detect unforeseen lesions such as gastrointestinal metastases because FDG-PET is a whole-body scan in a single-operation examination. FDG-PET imaging provided valuable information for the diagnosis of gastrointestinal metastasis. (author)

  16. jQC-PET, an ImageJ macro to analyse the quality control of a PET/CT

    International Nuclear Information System (INIS)

    Cortes-Rodicio, J.; Sanchez-Merino, G.; Garcia-Fidalgo, A.

    2015-01-01

    An ImageJ macro has been developed to facilitate the analysis of three PET/CT quality control procedures included in the documents from the National Electrical Manufacturers Association (NU2-2007) and the International Atomic Energy Agency (Pub-1393): image quality, uniformity and spatial resolution. In them, the generation of the regions of interest and the analysis are automatized. The results obtained with the software have been compared with those of the commercial software and the literature. The use of jQC-PET allows a standard analysis and the independence of the commercial software. (Author)

  17. Evaluation of GMI and PMI diffeomorphic-based demons algorithms for aligning PET and CT Images.

    Science.gov (United States)

    Yang, Juan; Wang, Hongjun; Zhang, You; Yin, Yong

    2015-07-08

    Fusion of anatomic information in computed tomography (CT) and functional information in 18F-FDG positron emission tomography (PET) is crucial for accurate differentiation of tumor from benign masses, designing radiotherapy treatment plan and staging of cancer. Although current PET and CT images can be acquired from combined 18F-FDG PET/CT scanner, the two acquisitions are scanned separately and take a long time, which may induce potential positional errors in global and local caused by respiratory motion or organ peristalsis. So registration (alignment) of whole-body PET and CT images is a prerequisite for their meaningful fusion. The purpose of this study was to assess the performance of two multimodal registration algorithms for aligning PET and CT images. The proposed gradient of mutual information (GMI)-based demons algorithm, which incorporated the GMI between two images as an external force to facilitate the alignment, was compared with the point-wise mutual information (PMI) diffeomorphic-based demons algorithm whose external force was modified by replacing the image intensity difference in diffeomorphic demons algorithm with the PMI to make it appropriate for multimodal image registration. Eight patients with esophageal cancer(s) were enrolled in this IRB-approved study. Whole-body PET and CT images were acquired from a combined 18F-FDG PET/CT scanner for each patient. The modified Hausdorff distance (d(MH)) was used to evaluate the registration accuracy of the two algorithms. Of all patients, the mean values and standard deviations (SDs) of d(MH) were 6.65 (± 1.90) voxels and 6.01 (± 1.90) after the GMI-based demons and the PMI diffeomorphic-based demons registration algorithms respectively. Preliminary results on oncological patients showed that the respiratory motion and organ peristalsis in PET/CT esophageal images could not be neglected, although a combined 18F-FDG PET/CT scanner was used for image acquisition. The PMI diffeomorphic-based demons

  18. In Vivo PET Imaging of HDL in Multiple Atherosclerosis Models

    DEFF Research Database (Denmark)

    Pérez-Medina, Carlos; Binderup, Tina; Lobatto, Mark E

    2016-01-01

    . Ex vivo validation was conducted by radioactivity counting, autoradiography, and near-infrared fluorescence imaging. Flow cytometric assessment of cellular specificity in different tissues was performed in the murine model. RESULTS: We observed distinct pharmacokinetic profiles for the two (89)Zr......OBJECTIVES: The goal of this study was to develop and validate a noninvasive imaging tool to visualize the in vivo behavior of high-density lipoprotein (HDL) by using positron emission tomography (PET), with an emphasis on its plaque-targeting abilities. BACKGROUND: HDL is a natural nanoparticle......,2-distearoyl-sn-glycero-3-phosphoethanolamine-deferoxamine B). Biodistribution and plaque targeting of radiolabeled HDL were studied in established murine, rabbit, and porcine atherosclerosis models by using PET combined with computed tomography (PET/CT) imaging or PET combined with magnetic resonance imaging...

  19. Combined PET/MR imaging in neurology

    DEFF Research Database (Denmark)

    Andersen, Flemming Littrup; Ladefoged, Claes Nøhr; Beyer, Thomas

    2014-01-01

    AIM: Combined PET/MR systems have now become available for clinical use. Given the lack of integrated standard transmission (TX) sources in these systems, attenuation and scatter correction (AC) must be performed using the available MR-images. Since bone tissue cannot easily be accounted for duri...

  20. Image reconstruction of mMR PET data using the open source software STIR

    Energy Technology Data Exchange (ETDEWEB)

    Markiewicz, Pawel [Centre for Medical Image Computing, University College London, London (United Kingdom); Thielemans, Kris [Institute of Nuclear Medicine, University College London, London (United Kingdom); Burgos, Ninon [Centre for Medical Image Computing, University College London, London (United Kingdom); Manber, Richard [Institute of Nuclear Medicine, University College London, London (United Kingdom); Jiao, Jieqing [Centre for Medical Image Computing, University College London, London (United Kingdom); Barnes, Anna [Institute of Nuclear Medicine, University College London, London (United Kingdom); Atkinson, David [Centre for Medical Imaging, University College London, London (United Kingdom); Arridge, Simon R [Centre for Medical Image Computing, University College London, London (United Kingdom); Hutton, Brian F [Institute of Nuclear Medicine, University College London, London (United Kingdom); Ourselin, Sébastien [Centre for Medical Image Computing, University College London, London (United Kingdom); Dementia Research Centre, University College London, London (United Kingdom)

    2014-07-29

    Simultaneous PET and MR acquisitions have now become possible with the new hybrid Biograph Molecular MR (mMR) scanner from Siemens. The purpose of this work is to create a platform for mMR 3D and 4D PET image reconstruction which would be freely accessible to the community as well as fully adjustable in order to obtain optimal images for a given research task in PET imaging. The proposed platform is envisaged to prove useful in developing novel and robust image bio-markers which could then be adapted for use on the mMR scanner.

  1. Image reconstruction of mMR PET data using the open source software STIR

    International Nuclear Information System (INIS)

    Markiewicz, Pawel; Thielemans, Kris; Burgos, Ninon; Manber, Richard; Jiao, Jieqing; Barnes, Anna; Atkinson, David; Arridge, Simon R; Hutton, Brian F; Ourselin, Sébastien

    2014-01-01

    Simultaneous PET and MR acquisitions have now become possible with the new hybrid Biograph Molecular MR (mMR) scanner from Siemens. The purpose of this work is to create a platform for mMR 3D and 4D PET image reconstruction which would be freely accessible to the community as well as fully adjustable in order to obtain optimal images for a given research task in PET imaging. The proposed platform is envisaged to prove useful in developing novel and robust image bio-markers which could then be adapted for use on the mMR scanner.

  2. Positron Emission Tomography imaging with the SmartPET system

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, R.J. [Department of Physics, University of Liverpool, Liverpool, Merseyside L69 7ZE (United Kingdom)], E-mail: cooperrj@ornl.gov; Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Grint, A.N.; Harkness, L.J.; Nolan, P.J.; Oxley, D.C.; Scraggs, D.P.; Mather, A.R. [Department of Physics, University of Liverpool, Liverpool, Merseyside L69 7ZE (United Kingdom); Lazarus, I.; Simpson, J. [STFC Daresbury Laboratory, Daresbury, Warrington, Cheshire WA4 4AD (United Kingdom)

    2009-07-21

    The Small Animal Reconstruction Tomograph for Positron Emission Tomography (SmartPET) project is the development of a small animal Positron Emission Tomography (PET) demonstrator based on the use of High-Purity Germanium (HPGe) detectors and state of the art digital electronics. The experimental results presented demonstrate the current performance of this unique system. By performing high precision measurements of one of the SmartPET HPGe detectors with a range of finely collimated gamma-ray beams the response of the detector as a function of gamma-ray interaction position has been quantified, facilitating the development of parametric Pulse Shape Analysis (PSA) techniques and algorithms for the correction of imperfections in detector performance. These algorithms have then been applied to data from PET imaging measurements using two such detectors in conjunction with a specially designed rotating gantry. In this paper we show how the use of parametric PSA approaches allows over 60% of coincident events to be processed and how the nature and complexity of an event has direct implications for the quality of the resulting image.

  3. 3D conditional generative adversarial networks for high-quality PET image estimation at low dose.

    Science.gov (United States)

    Wang, Yan; Yu, Biting; Wang, Lei; Zu, Chen; Lalush, David S; Lin, Weili; Wu, Xi; Zhou, Jiliu; Shen, Dinggang; Zhou, Luping

    2018-07-01

    Positron emission tomography (PET) is a widely used imaging modality, providing insight into both the biochemical and physiological processes of human body. Usually, a full dose radioactive tracer is required to obtain high-quality PET images for clinical needs. This inevitably raises concerns about potential health hazards. On the other hand, dose reduction may cause the increased noise in the reconstructed PET images, which impacts the image quality to a certain extent. In this paper, in order to reduce the radiation exposure while maintaining the high quality of PET images, we propose a novel method based on 3D conditional generative adversarial networks (3D c-GANs) to estimate the high-quality full-dose PET images from low-dose ones. Generative adversarial networks (GANs) include a generator network and a discriminator network which are trained simultaneously with the goal of one beating the other. Similar to GANs, in the proposed 3D c-GANs, we condition the model on an input low-dose PET image and generate a corresponding output full-dose PET image. Specifically, to render the same underlying information between the low-dose and full-dose PET images, a 3D U-net-like deep architecture which can combine hierarchical features by using skip connection is designed as the generator network to synthesize the full-dose image. In order to guarantee the synthesized PET image to be close to the real one, we take into account of the estimation error loss in addition to the discriminator feedback to train the generator network. Furthermore, a concatenated 3D c-GANs based progressive refinement scheme is also proposed to further improve the quality of estimated images. Validation was done on a real human brain dataset including both the normal subjects and the subjects diagnosed as mild cognitive impairment (MCI). Experimental results show that our proposed 3D c-GANs method outperforms the benchmark methods and achieves much better performance than the state

  4. Novel PET and Near Infrared Imaging Probes for the Specific Detection of Bacterial Infections Associated With Cardiac Devices.

    Science.gov (United States)

    Takemiya, Kiyoko; Ning, Xinghai; Seo, Wonewoo; Wang, Xiaojian; Mohammad, Rafi; Joseph, Giji; Titterington, Jane S; Kraft, Colleen S; Nye, Jonathan A; Murthy, Niren; Goodman, Mark M; Taylor, W Robert

    2018-04-13

    The aim of this study was to develop imaging agents to detect early stage infections in implantable cardiac devices. Bacteria ingest maltodextrins through the specific maltodextrin transporter. We developed probes conjugated with either a fluorescent dye (maltohexaose fluorescent dye probe [MDP]) or a F-18 (F18 fluoromaltohexaose) and determined their usefulness in a model of infections associated with implanted cardiac devices. Stainless steel mock-ups of medical devices were implanted subcutaneously in rats. On post-operative day 4, animals were injected with either Staphylococcus aureus around the mock-ups to induce a relatively mild infection or oil of turpentine to induce noninfectious inflammation. Animals with a sterile implant were used as control subjects. On post-operative day 6, either the MDP or F18 fluoromaltohexaose was injected intravenously, and the animals were scanned with the appropriate imaging device. Additional positron emission tomography imaging studies were performed with F18-fluorodeoxyglucose as a comparison of the specificity of our probes (n = 5 to 9 per group). The accumulation of the MDP in the infected rats was significantly increased at 1 h after injection when compared with the control and noninfectious inflammation groups (intensity ratio 1.54 ± 0.07 vs. 1.26 ± 0.04 and 1.20 ± 0.05, respectively; p F18 fluoromaltohexaose and F18 fluorodeoxyglucose significantly accumulated in the infected area 30 min after the injection (maximum standard uptake value ratio 4.43 ± 0.30 and 4.87 ± 0.28, respectively). In control rats, there was no accumulation of imaging probes near the device. In the noninfectious inflammation rats, no significant accumulation was observed with F18 fluoromaltohexaose, but F18 fluorodeoxyglucose accumulated in the mock-up area (maximum standard uptake value 2.53 ± 0.39 vs. 4.74 ± 0.46, respectively; p < 0.05). Our results indicate that maltohexaose-based imaging probes are potentially useful for the

  5. 2D imaging simulations of a small animal PET scanner with DOI measurement. jPET-RD

    International Nuclear Information System (INIS)

    Yamaya, Taiga; Hagiwara, Naoki

    2005-01-01

    We present a preliminary study on the design of a high sensitivity small animal depth of interaction (DOI)-PET scanner: jPET-RD (for Rodents with DOI detectors), which will contribute to molecular imaging. The 4-layer DOI block detector for the jPET-RD that consists of scintillation crystals (1.4 mm x 1.4 mm x 4.5 mm) and a flat panel position-sensitive photomultiplier tube (52 mm x 52 mm) was previously proposed. In this paper, we investigate imaging performance of the jPET-RD through numerical simulations. The scanner has a hexagonal geometry with a small diameter and a large axial aperture. Therefore DOI information is expected to improve resolution uniformity in the whole field of view (FOV). We simulate the scanner for various parameters of the number of DOI channels and the crystal length. Simulated data are reconstructed using the maximum likelihood expectation maximization with accurate system modeling. The trade-off results between background noise and spatial resolution show that only shortening the length of crystal does not improve the trade-off at all, and that 4-layer DOI information improves uniformity of spatial resolution in the whole FOV. Excellent performance of the jPET-RD can be expected based on the numerical simulation results. (author)

  6. FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0

    International Nuclear Information System (INIS)

    Boellaard, Ronald; Hoekstra, Otto S.; Delgado-Bolton, Roberto; Oyen, Wim J.G.; Visser, Eric; Giammarile, Francesco; Tatsch, Klaus; Eschner, Wolfgang; Verzijlbergen, Fred J.; Barrington, Sally F.; Pike, Lucy C.; Weber, Wolfgang A.; Stroobants, Sigrid; Delbeke, Dominique; Donohoe, Kevin J.; Holbrook, Scott; Graham, Michael M.; Testanera, Giorgio; Chiti, Arturo; Zijlstra, Josee; Hoekstra, Corneline J.; Pruim, Jan; Willemsen, Antoon; Arends, Bertjan; Kotzerke, Joerg; Bockisch, Andreas; Beyer, Thomas; Krause, Bernd J.

    2015-01-01

    The purpose of these guidelines is to assist physicians in recommending, performing, interpreting and reporting the results of FDG PET/CT for oncological imaging of adult patients. PET is a quantitative imaging technique and therefore requires a common quality control (QC)/quality assurance (QA) procedure to maintain the accuracy and precision of quantitation. Repeatability and reproducibility are two essential requirements for any quantitative measurement and/or imaging biomarker. Repeatability relates to the uncertainty in obtaining the same result in the same patient when he or she is examined more than once on the same system. However, imaging biomarkers should also have adequate reproducibility, i.e. the ability to yield the same result in the same patient when that patient is examined on different systems and at different imaging sites. Adequate repeatability and reproducibility are essential for the clinical management of patients and the use of FDG PET/CT within multicentre trials. A common standardised imaging procedure will help promote the appropriate use of FDG PET/CT imaging and increase the value of publications and, therefore, their contribution to evidence-based medicine. Moreover, consistency in numerical values between platforms and institutes that acquire the data will potentially enhance the role of semiquantitative and quantitative image interpretation. Precision and accuracy are additionally important as FDG PET/CT is used to evaluate tumour response as well as for diagnosis, prognosis and staging. Therefore both the previous and these new guidelines specifically aim to achieve standardised uptake value harmonisation in multicentre settings. (orig.)

  7. FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0

    Energy Technology Data Exchange (ETDEWEB)

    Boellaard, Ronald; Hoekstra, Otto S. [VU University Medical Centre, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands); Delgado-Bolton, Roberto [University of La Rioja, Department of Diagnostic Imaging (Radiology) and Nuclear Medicine, San Pedro Hospital and Centre for Biomedical Research of La Rioja (CIBIR), Logrono, La Rioja (Spain); Oyen, Wim J.G.; Visser, Eric [Radboud University Nijmegen Medical Centre, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands); Giammarile, Francesco [Centre Hospitalier Universitaire de Lyon, Department of Nuclear Medicine, Lyon (France); Tatsch, Klaus [Municipal Hospital Karlsruhe Inc., Department of Nuclear Medicine, Karlsruhe (Germany); Eschner, Wolfgang [University of Cologne, Department of Nuclear Medicine, Cologne (Germany); Verzijlbergen, Fred J. [Erasmus Medical Center, Department of Nuclear Medicine, Rotterdam (Netherlands); Barrington, Sally F.; Pike, Lucy C. [King' s College London, King' s Health Partners, PET Imaging Centre, St Thomas' Hospital, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Weber, Wolfgang A. [Memorial Sloan Kettering Center, Department of Radiology, New York, NY (United States); Stroobants, Sigrid [Antwerp University Hospital, Department of Nuclear Medicine, Antwerp (Belgium); Delbeke, Dominique [Vanderbilt University Medical Center, Department of Radiology and Radiological Sciences, Nashville, TN (United States); Donohoe, Kevin J. [Beth Israel Deaconess Medical Center, Boston, MA (United States); Holbrook, Scott [Invivo Molecular Imaging LLC, Gray, TN (United States); Graham, Michael M. [University of Iowa, Department of Radiology, Iowa City, IA (United States); Testanera, Giorgio; Chiti, Arturo [Humanitas Clinical and Research Center, Department of Nuclear Medicine, Rozzano, MI (Italy); Zijlstra, Josee [VU University Medical Centre, Department of Hematology, Amsterdam (Netherlands); Hoekstra, Corneline J. [Jeroen Bosch Hospital, Department of Nuclear Medicine, Den Bosch (Netherlands); Pruim, Jan; Willemsen, Antoon [University Medical Centre Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Arends, Bertjan [Catharina Hospital, Department of Clinical Physics, Eindhoven (Netherlands); Kotzerke, Joerg [University Hospital Dresden, Clinic and Outpatient Clinic for Nuclear Medicine, Dresden (Germany); Bockisch, Andreas [University Hospital Essen, Clinic for Nuclear Medicine, Essen (Germany); Beyer, Thomas [Medical University of Vienna, Centre for Medical Physics and Biomedical Engineering, Vienna (Austria); Krause, Bernd J. [University Hospital Rostock, Department of Nuclear Medicine, Rostock (Germany)

    2014-12-02

    The purpose of these guidelines is to assist physicians in recommending, performing, interpreting and reporting the results of FDG PET/CT for oncological imaging of adult patients. PET is a quantitative imaging technique and therefore requires a common quality control (QC)/quality assurance (QA) procedure to maintain the accuracy and precision of quantitation. Repeatability and reproducibility are two essential requirements for any quantitative measurement and/or imaging biomarker. Repeatability relates to the uncertainty in obtaining the same result in the same patient when he or she is examined more than once on the same system. However, imaging biomarkers should also have adequate reproducibility, i.e. the ability to yield the same result in the same patient when that patient is examined on different systems and at different imaging sites. Adequate repeatability and reproducibility are essential for the clinical management of patients and the use of FDG PET/CT within multicentre trials. A common standardised imaging procedure will help promote the appropriate use of FDG PET/CT imaging and increase the value of publications and, therefore, their contribution to evidence-based medicine. Moreover, consistency in numerical values between platforms and institutes that acquire the data will potentially enhance the role of semiquantitative and quantitative image interpretation. Precision and accuracy are additionally important as FDG PET/CT is used to evaluate tumour response as well as for diagnosis, prognosis and staging. Therefore both the previous and these new guidelines specifically aim to achieve standardised uptake value harmonisation in multicentre settings. (orig.)

  8. Bimodal MR-PET agent for quantitative pH imaging

    Science.gov (United States)

    Frullano, Luca; Catana, Ciprian; Benner, Thomas; Sherry, A. Dean; Caravan, Peter

    2010-01-01

    Activatable or “smart” magnetic resonance contrast agents have relaxivities that depend on environmental factors such as pH or enzymatic activity, but the MR signal depends on relaxivity and agent concentration – two unknowns. A bimodal approach, incorporating a positron emitter, solves this problem. Simultaneous positron emission tomography (PET) and MR imaging with the biomodal, pH-responsive MR-PET agent GdDOTA-4AMP-F allows direct determination of both concentration (PET) and T1 (MRI), and hence pH. PMID:20191650

  9. SU-C-9A-06: The Impact of CT Image Used for Attenuation Correction in 4D-PET

    International Nuclear Information System (INIS)

    Cui, Y; Bowsher, J; Yan, S; Cai, J; Das, S; Yin, F

    2014-01-01

    Purpose: To evaluate the appropriateness of using 3D non-gated CT image for attenuation correction (AC) in a 4D-PET (gated PET) imaging protocol used in radiotherapy treatment planning simulation. Methods: The 4D-PET imaging protocol in a Siemens PET/CT simulator (Biograph mCT, Siemens Medical Solutions, Hoffman Estates, IL) was evaluated. CIRS Dynamic Thorax Phantom (CIRS Inc., Norfolk, VA) with a moving glass sphere (8 mL) in the middle of its thorax portion was used in the experiments. The glass was filled with 18 F-FDG and was in a longitudinal motion derived from a real patient breathing pattern. Varian RPM system (Varian Medical Systems, Palo Alto, CA) was used for respiratory gating. Both phase-gating and amplitude-gating methods were tested. The clinical imaging protocol was modified to use three different CT images for AC in 4D-PET reconstruction: first is to use a single-phase CT image to mimic actual clinical protocol (single-CT-PET); second is to use the average intensity projection CT (AveIP-CT) derived from 4D-CT scanning (AveIP-CT-PET); third is to use 4D-CT image to do the phase-matched AC (phase-matching- PET). Maximum SUV (SUVmax) and volume of the moving target (glass sphere) with threshold of 40% SUVmax were calculated for comparison between 4D-PET images derived with different AC methods. Results: The SUVmax varied 7.3%±6.9% over the breathing cycle in single-CT-PET, compared to 2.5%±2.8% in AveIP-CT-PET and 1.3%±1.2% in phasematching PET. The SUVmax in single-CT-PET differed by up to 15% from those in phase-matching-PET. The target volumes measured from single- CT-PET images also presented variations up to 10% among different phases of 4D PET in both phase-gating and amplitude-gating experiments. Conclusion: Attenuation correction using non-gated CT in 4D-PET imaging is not optimal process for quantitative analysis. Clinical 4D-PET imaging protocols should consider phase-matched 4D-CT image if available to achieve better accuracy

  10. SU-C-9A-06: The Impact of CT Image Used for Attenuation Correction in 4D-PET

    Energy Technology Data Exchange (ETDEWEB)

    Cui, Y; Bowsher, J; Yan, S; Cai, J; Das, S; Yin, F [Duke University Medical Center, Durham, NC (United States)

    2014-06-01

    Purpose: To evaluate the appropriateness of using 3D non-gated CT image for attenuation correction (AC) in a 4D-PET (gated PET) imaging protocol used in radiotherapy treatment planning simulation. Methods: The 4D-PET imaging protocol in a Siemens PET/CT simulator (Biograph mCT, Siemens Medical Solutions, Hoffman Estates, IL) was evaluated. CIRS Dynamic Thorax Phantom (CIRS Inc., Norfolk, VA) with a moving glass sphere (8 mL) in the middle of its thorax portion was used in the experiments. The glass was filled with {sup 18}F-FDG and was in a longitudinal motion derived from a real patient breathing pattern. Varian RPM system (Varian Medical Systems, Palo Alto, CA) was used for respiratory gating. Both phase-gating and amplitude-gating methods were tested. The clinical imaging protocol was modified to use three different CT images for AC in 4D-PET reconstruction: first is to use a single-phase CT image to mimic actual clinical protocol (single-CT-PET); second is to use the average intensity projection CT (AveIP-CT) derived from 4D-CT scanning (AveIP-CT-PET); third is to use 4D-CT image to do the phase-matched AC (phase-matching- PET). Maximum SUV (SUVmax) and volume of the moving target (glass sphere) with threshold of 40% SUVmax were calculated for comparison between 4D-PET images derived with different AC methods. Results: The SUVmax varied 7.3%±6.9% over the breathing cycle in single-CT-PET, compared to 2.5%±2.8% in AveIP-CT-PET and 1.3%±1.2% in phasematching PET. The SUVmax in single-CT-PET differed by up to 15% from those in phase-matching-PET. The target volumes measured from single- CT-PET images also presented variations up to 10% among different phases of 4D PET in both phase-gating and amplitude-gating experiments. Conclusion: Attenuation correction using non-gated CT in 4D-PET imaging is not optimal process for quantitative analysis. Clinical 4D-PET imaging protocols should consider phase-matched 4D-CT image if available to achieve better accuracy.

  11. PET imaging with the non-pure positron emitters: 55Co, 86Y and 124I

    DEFF Research Database (Denmark)

    Braad, Poul-Erik; Hansen, S B; Thisgaard, H

    2015-01-01

    PET/CT with non-pure positron emitters is a highly valuable tool in immuno-PET and for pretherapeutic dosimetry. However, imaging is complicated by prompt gamma coincidences (PGCs) that add an undesired background activity to the images. Time-of-flight (TOF) reconstruction improves lesion...... detectability in 18F-PET and can potentially also improve the signal-to-noise ratio in images acquired with non-pure positron emitters. Using the GE Discovery 690 PET/CT system, we evaluated the image quality with 55Co, 86Y and 124I, and the effect of PGC-correction and TOF-reconstruction on image quality...... and quantitation in a series of phantom studies. PET image quality and quantitation for all isotopes were significantly affected by PGCs. The effect was most severe with 86Y, and less, but comparable, with 55Co and 124I. PGC-correction improved the image quality and the quantitation accuracy dramatically for all...

  12. Image registration/fusion software for PET and CT/MRI by using simultaneous emission and transmission scans

    International Nuclear Information System (INIS)

    Kitamura, Keishi; Amano, Masaharu; Sato, Tomohiko; Okumura, Takeshi; Konishi, Norihiro; Komatsu, Masahiko

    2003-01-01

    When PET (positron emission tomography) is used for oncology studies, it is important to register and over-lay PET images with the images of other anatomical modalities, such as those obtained by CT (computed tomography) or MRI (magnetic resonance imaging), in order for the lesions to be anatomically located with high accuracy. The Shimadzu SET-2000W Series PET scanners provide simultaneous acquisition of emission and transmission data, which is capable of complete spatial alignment of both functional and attenuation images. This report describes our newly developed image registration/fusion software, which reformats PET emission images to the CT/MRI grid by using the transform matrix obtained by matching PET transmission images with CT/MRI images. Transmission images are registered and fused either automatically or manually, through 3-dimensional rotation and translation, with the transaxial, sagittal, and coronal fused images being monitored on the screen. This new method permits sufficiently accurate registration and efficient data processing with promoting effective use of CT/MRI images of the DICOM format, without using markers in data acquisition or any special equipment, such as a combined PET/CT scanner. (author)

  13. Clinical evaluation of 2D versus 3D whole-body PET image quality using a dedicated BGO PET scanner

    International Nuclear Information System (INIS)

    Visvikis, D.; Griffiths, D.; Costa, D.C.; Bomanji, J.; Ell, P.J.

    2005-01-01

    Three-dimensional positron emission tomography (3D PET) results in higher system sensitivity, with an associated increase in the detection of scatter and random coincidences. The objective of this work was to compare, from a clinical perspective, 3D and two-dimensional (2D) acquisitions in terms of whole-body (WB) PET image quality with a dedicated BGO PET system. 2D and 3D WB emission acquisitions were carried out in 70 patients. Variable acquisition parameters in terms of time of emission acquisition per axial field of view (aFOV) and slice overlap between sequential aFOVs were used during the 3D acquisitions. 3D and 2D images were reconstructed using FORE+WLS and OSEM respectively. Scatter correction was performed by convolution subtraction and a model-based scatter correction in 2D and 3D respectively. All WB images were attenuation corrected using segmented transmission scans. Images were blindly assessed by three observers for the presence of artefacts, confidence in lesion detection and overall image quality using a scoring system. Statistically significant differences between 2D and 3D image quality were only obtained for 3D emission acquisitions of 3 min. No statistically significant differences were observed for image artefacts or lesion detectability scores. Image quality correlated significantly with patient weight for both modes of operation. Finally, no differences were seen in image artefact scores for the different axial slice overlaps considered, suggesting the use of five slice overlaps in 3D WB acquisitions. 3D WB imaging using a dedicated BGO-based PET scanner offers similar image quality to that obtained in 2D considering similar overall times of acquisitions. (orig.)

  14. Three-dimensional display and measurement of cardiac dynamic indexes from MR images

    International Nuclear Information System (INIS)

    Kono, M.; Matsuo, M.; Yamasaki, K.; Banno, T.; Toriwaki, J.; Yokoi, S.; Oshita, H.

    1986-01-01

    The cardiac dynamic index, to which such variables as cardiac output, ejection fraction, and wall motion contribute, is routinely determined using various modalities such as angiography, radionuclide imaging, US, and x-ray CT. Each of these modalities, however, has some disadvantages in regard to evaluating the cardiac dynamic index. The authors have obtained precise multidirectional projection images of the heart by means of computer graphics and reformatted data of cardiac MR images obtained with cardiac gating. The contiguous coronal MR images of the heart are made at an interimage distance of 5 mm. In each section, five or six cardiac images can be obtained, depending on the systolic or diastolic phase. These images are stored in a computer, and a three-dimensional display of the heart with biocular observation and with multiplex holograms is made possible with computer graphics. Three-dimensional measurement of the cardiac index is now being attempted, including cardiac output, ejection fraction, and wall motion

  15. Clinical study of the image fusion between CT and FDG-PET in the head and neck region

    International Nuclear Information System (INIS)

    Shozushima, Masanori; Moriguchi, Hitoshi; Shoji, Satoru; Sakamaki, Kimio; Ishikawa, Yoshihito; Kudo, Keigo; Satoh, Masanobu

    1999-01-01

    Image fusion using PET and CT from the head and neck region was performed with the use of external markers on 7 patients with squamous cell carcinoma. The purpose of this study was to examine a resultant error and the clinical usefulness of image fusion. Patients had primary lesions of the tongue, the maxillary gingiva or the maxillary sinus. All patients underwent PET with FDG and CT to detect tumor sites. Of these 7 patients, diagnostic images and the clinical observation found 6 cases of regional lymph node metastasis of the neck. To ensure the anatomical detail of the PET images, small radioactive markers were placed on the philtrum and below both earlobes. The PET image and CT image were then overlapped on a computer. The image fusion of PET and CT was successfully performed on all patients. The superposition error of this method was examined between the PET and CT images. The accuracy of fit measured as the mean distance between the PET and CT image was in the range of 2-5 mm. PET-CT superimposed images produced an increase in the localization of tumor FDG uptake and localized FDG uptake on the palatine tonsils. The marker system described here for the alignment of PET and CT images can be used on a routine basis without the invasive fixation of external markers, and also improve the management and follow up on patients with head and neck carcinoma. (author)

  16. Optimized workflow and imaging protocols for whole-body oncologic PET/MRI.

    Science.gov (United States)

    Ishii, Shirou; Hara, Takamitsu; Nanbu, Takeyuki; Suenaga, Hiroki; Sugawara, Shigeyasu; Kuroiwa, Daichi; Sekino, Hirofumi; Miyajima, Masayuki; Kubo, Hitoshi; Oriuchi, Noboru; Ito, Hiroshi

    2016-11-01

    Although PET/MRI has the advantages of a simultaneous acquisition of PET and MRI, high soft-tissue contrast of the MRI images, and reduction of radiation exposure, its low profitability and long acquisition time are significant problems in clinical settings. Thus, MRI protocols that meet oncological purposes need to be used in order to reduce examination time while securing detectability. Currently, half-Fourier acquisition single-shot turbo spin echo and 3D-T1 volumetric interpolated breath-hold examination may be the most commonly used sequences for whole-body imaging due to their shorter acquisition time and higher diagnostic accuracy. Although there have been several reports that adding diffusion weighted image (DWI) to PET/MRI protocol has had no effect on tumor detection to date, in cases of liver, kidney, bladder, and prostate cancer, the use of DWI may be beneficial in detecting lesions. Another possible option is to scan each region with different MRI sequences instead of scanning the whole body using one sequence continuously. We herein report a workflow and imaging protocols for whole-body oncologic PET/MRI using an integrated system in the clinical routine, designed for the detection, for example by cancer screening, of metastatic lesions, in order to help future users optimize their workflow and imaging protocols.

  17. Optimization for PET imaging based on phantom study and NECdensity

    International Nuclear Information System (INIS)

    Daisaki, Hiromitsu; Shimada, Naoki; Shinohara, Hiroyuki

    2012-01-01

    In consideration of the requirement for global standardization and quality control of PET imaging, the present studies gave an outline of phantom study to decide both scan and reconstruction parameters based on FDG-PET/CT procedure guideline in Japan, and optimization of scan duration based on NEC density was performed continuously. In the phantom study, scan and reconstruction parameters were decided by visual assessment and physical indexes (N 10mm , NEC phantom , Q H,10mm /N 10mm ) to visualize hot spot of 10 mm diameter with standardized uptake value (SUV)=4 explicitly. Simultaneously, Recovery Coefficient (RC) was evaluated to recognize that PET images had enough quantifiably. Scan durations were optimized by Body Mass Index (BMI) based on retrospective analysis of NEC density . Correlation between visual score in clinical FDG-PET images and NEC density fell after the optimization of scan duration. Both Inter-institution and inter-patient variability were decreased by performing the phantom study based on the procedure guideline and the optimization of scan duration based on NEC density which seem finally useful to practice highly precise examination and promote high-quality controlled study. (author)

  18. A phantom design for assessment of detectability in PET imaging

    International Nuclear Information System (INIS)

    Wollenweber, Scott D.; Alessio, Adam M.; Kinahan, Paul E.

    2016-01-01

    Purpose: The primary clinical role of positron emission tomography (PET) imaging is the detection of anomalous regions of 18 F-FDG uptake, which are often indicative of malignant lesions. The goal of this work was to create a task-configurable fillable phantom for realistic measurements of detectability in PET imaging. Design goals included simplicity, adjustable feature size, realistic size and contrast levels, and inclusion of a lumpy (i.e., heterogeneous) background. Methods: The detection targets were hollow 3D-printed dodecahedral nylon features. The exostructure sphere-like features created voids in a background of small, solid non-porous plastic (acrylic) spheres inside a fillable tank. The features filled at full concentration while the background concentration was reduced due to filling only between the solid spheres. Results: Multiple iterations of feature size and phantom construction were used to determine a configuration at the limit of detectability for a PET/CT system. A full-scale design used a 20 cm uniform cylinder (head-size) filled with a fixed pattern of features at a contrast of approximately 3:1. Known signal-present and signal-absent PET sub-images were extracted from multiple scans of the same phantom and with detectability in a challenging (i.e., useful) range. These images enabled calculation and comparison of the quantitative observer detectability metrics between scanner designs and image reconstruction methods. The phantom design has several advantages including filling simplicity, wall-less contrast features, the control of the detectability range via feature size, and a clinically realistic lumpy background. Conclusions: This phantom provides a practical method for testing and comparison of lesion detectability as a function of imaging system, acquisition parameters, and image reconstruction methods and parameters.

  19. PET Imaging of Epigenetic Influences on Alzheimer’s Disease

    Directory of Open Access Journals (Sweden)

    Paul J. Couto

    2015-01-01

    Full Text Available The precise role of environment-gene interactions (epigenetics in the development and progression of Alzheimer’s disease (AD is unclear. This review focuses on the premise that radiotracer-specific PET imaging allows clinicians to visualize epigenetically influenced events and that such imaging may provide new, valuable insights for preventing, diagnosing, and treating AD. Current understanding of the role of epigenetics in AD and the principles underlying the use of PET radiotracers for in vivo diagnosis are reviewed. The relative efficacies of various PET radiotracers for visualizing the epigenetic influences on AD and their use for diagnosis are discussed. For example, [18F]FAHA demonstrates sites of differential HDAC activity, [18F]FDG indirectly illuminates sites of neuronal hypomethylation, and the carbon-11 isotope-containing Pittsburgh compound B ([11C]PiB images amyloid-beta plaque deposits. A definitive AD diagnosis is currently achievable only by postmortem histological observation of amyloid-beta plaques and tau neurofibrillary tangles. Therefore, reliable in vivo neuroimaging techniques could provide opportunities for early diagnosis and treatment of AD.

  20. Computerized method for evaluating diagnostic image quality of calcified plaque images in cardiac CT: Validation on a physical dynamic cardiac phantom

    International Nuclear Information System (INIS)

    King, Martin; Rodgers, Zachary; Giger, Maryellen L.; Bardo, Dianna M. E.; Patel, Amit R.

    2010-01-01

    Purpose: In cardiac computed tomography (CT), important clinical indices, such as the coronary calcium score and the percentage of coronary artery stenosis, are often adversely affected by motion artifacts. As a result, the expert observer must decide whether or not to use these indices during image interpretation. Computerized methods potentially can be used to assist in these decisions. In a previous study, an artificial neural network (ANN) regression model provided assessability (image quality) indices of calcified plaque images from the software NCAT phantom that were highly agreeable with those provided by expert observers. The method predicted assessability indices based on computer-extracted features of the plaque. In the current study, the ANN-predicted assessability indices were used to identify calcified plaque images with diagnostic calcium scores (based on mass) from a physical dynamic cardiac phantom. The basic assumption was that better quality images were associated with more accurate calcium scores. Methods: A 64-channel CT scanner was used to obtain 500 calcified plaque images from a physical dynamic cardiac phantom at different heart rates, cardiac phases, and plaque locations. Two expert observers independently provided separate sets of assessability indices for each of these images. Separate sets of ANN-predicted assessability indices tailored to each observer were then generated within the framework of a bootstrap resampling scheme. For each resampling iteration, the absolute calcium score error between the calcium scores of the motion-contaminated plaque image and its corresponding stationary image served as the ground truth in terms of indicating images with diagnostic calcium scores. The performances of the ANN-predicted and observer-assigned indices in identifying images with diagnostic calcium scores were then evaluated using ROC analysis. Results: Assessability indices provided by the first observer and the corresponding ANN performed

  1. Application of cross-species PET imaging to assess neurotransmitter release in brain.

    Science.gov (United States)

    Finnema, Sjoerd J; Scheinin, Mika; Shahid, Mohammed; Lehto, Jussi; Borroni, Edilio; Bang-Andersen, Benny; Sallinen, Jukka; Wong, Erik; Farde, Lars; Halldin, Christer; Grimwood, Sarah

    2015-11-01

    This review attempts to summarize the current status in relation to the use of positron emission tomography (PET) imaging in the assessment of synaptic concentrations of endogenous mediators in the living brain. Although PET radioligands are now available for more than 40 CNS targets, at the initiation of the Innovative Medicines Initiative (IMI) "Novel Methods leading to New Medications in Depression and Schizophrenia" (NEWMEDS) in 2009, PET radioligands sensitive to an endogenous neurotransmitter were only validated for dopamine. NEWMEDS work-package 5, "Cross-species and neurochemical imaging (PET) methods for drug discovery", commenced with a focus on developing methods enabling assessment of changes in extracellular concentrations of serotonin and noradrenaline in the brain. Sharing the workload across institutions, we utilized in vitro techniques with cells and tissues, in vivo receptor binding and microdialysis techniques in rodents, and in vivo PET imaging in non-human primates and humans. Here, we discuss these efforts and review other recently published reports on the use of radioligands to assess changes in endogenous levels of dopamine, serotonin, noradrenaline, γ-aminobutyric acid, glutamate, acetylcholine, and opioid peptides. The emphasis is on assessment of the availability of appropriate translational tools (PET radioligands, pharmacological challenge agents) and on studies in non-human primates and human subjects, as well as current challenges and future directions. PET imaging directed at investigating changes in endogenous neurochemicals, including the work done in NEWMEDS, have highlighted an opportunity to further extend the capability and application of this technology in drug development.

  2. Atlas of PET/CT. A quick guide to image interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Fanti, Stefano [Bologna Univ. (Italy). PET; Farsad, Mohsen [Central Hospital of Bolzano (Italy). Nuclear Medicine; Mansi, Luigi [Second Univ. of Naples (Italy). Nuclear Medicine

    2009-07-01

    This user-friendly atlas, featuring about 500 images, should be a quick guide to interpreting PET/CT images with FDG in oncology. It also illustrates how to recognize normal, para-physiological, and benign pathological uptakes in a case-based practical manner. The text, which includes most relevant technical and pathophysiological premises, covers the main clinical applications and clearly articulates learning points and pitfalls. This atlas aims to become a standard text for nuclear medicine physicians and radiologists, residents and technicians whose work involves PET/CT imaging. This book is also suitable for both undergraduate and postgraduate courses. (orig.)

  3. Fluorine-18 nuclide and its PET imaging agent

    International Nuclear Information System (INIS)

    Wang Mingfang

    2003-01-01

    Fluorine-18 has predominant physical features with long half-life and the enough time for preparation of radiopharmaceuticals and PET imaging. Also, the chemical nature of fluorine-18 is similar to that of hydrogen, and the fluorine-18 labelled organic molecules can not change the non-labelled molecular character. Therefore, fluorine-18 is widely applied in the labelled glucose, amino acids, fatty acids, nucleotide, receptor-ligand and neurotransmitter molecular etc., with the propose of detecting the blood flow, metabolism, synthesis of the protein and the neurotransmitter function in brain by PET imaging. It is very important in the basic science and clinical research to understand and master the preparation of the fluorine-18 and its labelled compounds

  4. Integrated PET/MR breast cancer imaging: Attenuation correction and implementation of a 16-channel RF coil

    Energy Technology Data Exchange (ETDEWEB)

    Oehmigen, Mark, E-mail: mark.oehmigen@uni-due.de; Lindemann, Maike E. [High Field and Hybrid MR Imaging, University Hospital Essen, Essen 45147 (Germany); Lanz, Titus [Rapid Biomedical GmbH, Rimpar 97222 (Germany); Kinner, Sonja [Institute for Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen 45147 (Germany); Quick, Harald H. [High Field and Hybrid MR Imaging, University Hospital Essen, Essen 45147, Germany and Erwin L. Hahn Institute for MR Imaging, University Duisburg-Essen, Essen 45141 (Germany)

    2016-08-15

    Purpose: This study aims to develop, implement, and evaluate a 16-channel radiofrequency (RF) coil for integrated positron emission tomography/magnetic resonance (PET/MR) imaging of breast cancer. The RF coil is designed for optimized MR imaging performance and PET transparency and attenuation correction (AC) is applied for accurate PET quantification. Methods: A 16-channel breast array RF coil was designed for integrated PET/MR hybrid imaging of breast cancer lesions. The RF coil features a lightweight rigid design and is positioned with a spacer at a defined position on the patient table of an integrated PET/MR system. Attenuation correction is performed by generating and applying a dedicated 3D CT-based template attenuation map. Reposition accuracy of the RF coil on the system patient table while using the positioning frame was tested in repeated measurements using MR-visible markers. The MR, PET, and PET/MR imaging performances were systematically evaluated using modular breast phantoms. Attenuation correction of the RF coil was evaluated with difference measurements of the active breast phantoms filled with radiotracer in the PET detector with and without the RF coil in place, serving as a standard of reference measurement. The overall PET/MR imaging performance and PET quantification accuracy of the new 16-channel RF coil and its AC were then evaluated in first clinical examinations on ten patients with local breast cancer. Results: The RF breast array coil provides excellent signal-to-noise ratio and signal homogeneity across the volume of the breast phantoms in MR imaging and visualizes small structures in the phantoms down to 0.4 mm in plane. Difference measurements with PET revealed a global loss and thus attenuation of counts by 13% (mean value across the whole phantom volume) when the RF coil is placed in the PET detector. Local attenuation ranging from 0% in the middle of the phantoms up to 24% was detected in the peripheral regions of the phantoms at

  5. Analysis and clinical usefullness of cardiac ECT images

    International Nuclear Information System (INIS)

    Hayashi, Makoto; Kagawa, Masaaki; Yamada, Yukinori

    1983-01-01

    We estimated basically and clinically myocardial ECT image and ECG gated cardiac blood-pool ECT image. ROC curve is used for the evaluation of the accuracy in diagnostic myocardial infarction. The accuracy in diagnostic of MI is superior in myocardial ECT image and ECT estimation is unnecessary skillfulness and experience. We can absene the whole defect of MI than planar image by using ECT. LVEDV between estimated volume and contrast volume is according to it and get one step for automatic analysis of cardiac volume. (author)

  6. Cardiac carcinoid: tricuspid delayed hyperenhancement on cardiac 64-slice multidetector CT and magnetic resonance imaging.

    LENUS (Irish Health Repository)

    Martos, R

    2012-02-01

    INTRODUCTION: Carcinoid heart disease is a rare condition in adults. Its diagnosis can be easily missed in a patient presenting to a primary care setting. We revised the advantages of using coronary multidetector computed tomography (MDCT) and cardiac magnetic resonance imaging (MRI) in diagnosing this condition. MATERIALS AND METHODS: We studied a 65-year-old patient with carcinoid heart disease and right heart failure using transthoracic Doppler-echocardiogram, cardiac MDCT and MRI. Cardiac echocardiogram revealed marked thickening and retraction of the tricuspid leaflets with dilated right atrium and ventricle. Cardiac MDCT and MRI demonstrated fixation and retraction of the tricuspid leaflets with delayed contrast hyperenhancement of the tricuspid annulus. CONCLUSION: This case demonstrates fascinating imaging findings of cardiac carcinoid disease and highlights the increasing utility of contrast-enhanced MRI and cardiac MDCT in the diagnosis of this interesting condition.

  7. Development of a small prototype for a proof-of-concept of OpenPET imaging

    International Nuclear Information System (INIS)

    Yamaya, Taiga; Yoshida, Eiji; Wakizaka, Hidekatsu; Kokuryo, Daisuke; Tsuji, Atsushi; Mitsuhashi, Takayuki; Tashima, Hideaki; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo; Kinouchi, Shoko; Inaniwa, Taku; Sato, Shinji; Nakajima, Yasunori; Kawai, Hideyuki; Haneishi, Hideaki; Suga, Mikio

    2011-01-01

    The OpenPET geometry is our new idea to visualize a physically opened space between two detector rings. In this paper, we developed the first small prototype to show a proof-of-concept of OpenPET imaging. Two detector rings of 110 mm diameter and 42 mm axial length were placed with a gap of 42 mm. The basic imaging performance was confirmed through phantom studies; the open imaging was realized at the cost of slight loss of axial resolution and 24% loss of sensitivity. For a proof-of-concept of PET image-guided radiation therapy, we carried out the in-beam tests with 11 C radioactive beam irradiation in the heavy ion medical accelerator in Chiba to visualize in situ distribution of primary particles stopped in a phantom. We showed that PET images corresponding to dose distribution were obtained. For an initial proof-of-concept of real-time multimodal imaging, we measured a tumor-inoculated mouse with 18 F-FDG, and an optical image of the mouse body surface was taken during the PET measurement by inserting a digital camera in the ring gap. We confirmed that the tumor in the gap was clearly visualized. The result also showed the extension effect of an axial field-of-view (FOV); a large axial FOV of 126 mm was obtained with the detectors that originally covered only an 84 mm axial FOV. In conclusion, our initial imaging studies showed promising performance of the OpenPET.

  8. Development of a small prototype for a proof-of-concept of OpenPET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yamaya, Taiga; Yoshida, Eiji; Wakizaka, Hidekatsu; Kokuryo, Daisuke; Tsuji, Atsushi; Mitsuhashi, Takayuki; Tashima, Hideaki; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo; Kinouchi, Shoko [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Inaniwa, Taku; Sato, Shinji [Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Nakajima, Yasunori [Interdisciplinary Graduate School of Science and Engineering, Tokyo Institute of Technology, 4259 Nagatsuta, Midori-ku, Yokohama, Kanagawa 226-8503 (Japan); Kawai, Hideyuki; Haneishi, Hideaki; Suga, Mikio, E-mail: taiga@nirs.go.jp [Chiba University, 1-33 Yayoicho, Inage-ku, Chiba 263-8522 (Japan)

    2011-02-21

    The OpenPET geometry is our new idea to visualize a physically opened space between two detector rings. In this paper, we developed the first small prototype to show a proof-of-concept of OpenPET imaging. Two detector rings of 110 mm diameter and 42 mm axial length were placed with a gap of 42 mm. The basic imaging performance was confirmed through phantom studies; the open imaging was realized at the cost of slight loss of axial resolution and 24% loss of sensitivity. For a proof-of-concept of PET image-guided radiation therapy, we carried out the in-beam tests with {sup 11}C radioactive beam irradiation in the heavy ion medical accelerator in Chiba to visualize in situ distribution of primary particles stopped in a phantom. We showed that PET images corresponding to dose distribution were obtained. For an initial proof-of-concept of real-time multimodal imaging, we measured a tumor-inoculated mouse with {sup 18}F-FDG, and an optical image of the mouse body surface was taken during the PET measurement by inserting a digital camera in the ring gap. We confirmed that the tumor in the gap was clearly visualized. The result also showed the extension effect of an axial field-of-view (FOV); a large axial FOV of 126 mm was obtained with the detectors that originally covered only an 84 mm axial FOV. In conclusion, our initial imaging studies showed promising performance of the OpenPET.

  9. PET image reconstruction with rotationally symmetric polygonal pixel grid based highly compressible system matrix

    International Nuclear Information System (INIS)

    Yu Yunhan; Xia Yan; Liu Yaqiang; Wang Shi; Ma Tianyu; Chen Jing; Hong Baoyu

    2013-01-01

    To achieve a maximum compression of system matrix in positron emission tomography (PET) image reconstruction, we proposed a polygonal image pixel division strategy in accordance with rotationally symmetric PET geometry. Geometrical definition and indexing rule for polygonal pixels were established. Image conversion from polygonal pixel structure to conventional rectangular pixel structure was implemented using a conversion matrix. A set of test images were analytically defined in polygonal pixel structure, converted to conventional rectangular pixel based images, and correctly displayed which verified the correctness of the image definition, conversion description and conversion of polygonal pixel structure. A compressed system matrix for PET image recon was generated by tap model and tested by forward-projecting three different distributions of radioactive sources to the sinogram domain and comparing them with theoretical predictions. On a practical small animal PET scanner, a compress ratio of 12.6:1 of the system matrix size was achieved with the polygonal pixel structure, comparing with the conventional rectangular pixel based tap-mode one. OS-EM iterative image reconstruction algorithms with the polygonal and conventional Cartesian pixel grid were developed. A hot rod phantom was detected and reconstructed based on these two grids with reasonable time cost. Image resolution of reconstructed images was both 1.35 mm. We conclude that it is feasible to reconstruct and display images in a polygonal image pixel structure based on a compressed system matrix in PET image reconstruction. (authors)

  10. Cardiac PET/CT for the diagnosis and prognostic evaluation of coronary artery disease

    International Nuclear Information System (INIS)

    Geronazzo, R.J.; Romero, R.L.; Campisi, R.

    2014-01-01

    Coronary artery disease is considered by de World Health Organization (WHO) to be pandemic. Eighty percent of the deaths occurs secondary to coronary artery disease, stroke and diabetes, thus they can be prevented. All of them are related to the same risk factors. Ischemic heart disease is the mayor cause of death in Argentina in the elderly population. Primary prevention strategies are essential in the health system. Hence, image complementary methods are very important to accomplish risk stratification, secondary prevention and pre-surgical evaluation. Nuclear cardiology has occupied this place through myocardial perfusion studies with radiopharmaceuticals, using SPECT (Single photon emission computed tomography) that have improved the level of sensitivity and specificity with ECG gated. Furthermore, positron emission tomography (PET) can evaluate relative myocardial perfusion, quantify absolute myocardial blood flow and coronary flow reserve. With its capacity to quantify rest-peak stress left ventricular systolic function we can underscore for example “balance ischemia”. By using hybrid PET/CT, also we can get information of coronary artery calcium scoring and coronary angiography. Currently, with the available softwares, we can acquire images in List mode. It means, from a single acquisition, it allows multiple image reconstructions, along with the associated electrocardiographic phase. PET/CT uses radiopharmaceuticals with short physical half life, and in conjunction with the possibility of acquiring in 3D mode, the perfusion studies can be done in a short time and offers lower radiation exposure to the patient. The new softwares for routine correction of misalignments between transmission and emission images have helped to reduce the frequency of artifacts and improve diagnostic accuracy. Hybrid PET/CT technology allows functional evaluation of myocardial perfusion combined with anatomic characterization of the epicardial coronary arteries, thereby

  11. New concepts in cardiac imaging 1985

    Energy Technology Data Exchange (ETDEWEB)

    Pohost, G.M.; Higgins, C.B.; Morganroth, J.; Ritchie, J.L.; Schelbert, H.R.

    1985-01-01

    This book presents 5 specialists work on reviewing and editing the area of applications for cardiac imaging: Contents: Ultrasound Methods; 1. Echocardiography in Valvular Heart Disease, 2. Echocardiography in Ischemic Heart Disease, 3. Current Status of Doppler Ultrasound for Assessing Regurgitant Valvular Lesions, Radionuclide Methods; 4. Cardiovascular Nuclear Medicine, 5. Single Photon Emission Computed Tomography (SPECT): Validation and Application for Myocardial Perfusion Imaging, 6. Assessment of Regional Myocardial Perfusion with Positron Emission Tomography, 7. Assessment of Regional Myocardial Substrate Metabolism with Positron Emission Tomography, X-Ray Imaging Techniques; 8. The Evaluation of Left Ventricular Function in Ischemic Heart Disease by Digital Subtraction Angigraphy, 9. Digital Angiography in the Assessment of Coronary Artery Disease, 10. Cardiac Computed Tomography: Its Potential Use in Evaluation of Ischemic Heart Disease, Magnetic Methods; 11. NMR Evaluation of the Cardiovascular System, 12. Magnetic Resonance Imaging of the Heart.

  12. New concepts in cardiac imaging 1985

    International Nuclear Information System (INIS)

    Pohost, G.M.; Higgins, C.B.; Morganroth, J.; Ritchie, J.L.; Schelbert, H.R.

    1985-01-01

    This book presents 5 specialists work on reviewing and editing the area of applications for cardiac imaging: Contents: Ultrasound Methods; 1. Echocardiography in Valvular Heart Disease, 2. Echocardiography in Ischemic Heart Disease, 3. Current Status of Doppler Ultrasound for Assessing Regurgitant Valvular Lesions, Radionuclide Methods; 4. Cardiovascular Nuclear Medicine, 5. Single Photon Emission Computed Tomography (SPECT): Validation and Application for Myocardial Perfusion Imaging, 6. Assessment of Regional Myocardial Perfusion with Positron Emission Tomography, 7. Assessment of Regional Myocardial Substrate Metabolism with Positron Emission Tomography, X-Ray Imaging Techniques; 8. The Evaluation of Left Ventricular Function in Ischemic Heart Disease by Digital Subtraction Angigraphy, 9. Digital Angiography in the Assessment of Coronary Artery Disease, 10. Cardiac Computed Tomography: Its Potential Use in Evaluation of Ischemic Heart Disease, Magnetic Methods; 11. NMR Evaluation of the Cardiovascular System, 12. Magnetic Resonance Imaging of the Heart

  13. Whole-body PET/MRI: The effect of bone attenuation during MR-based attenuation correction in oncology imaging

    DEFF Research Database (Denmark)

    Aznar, M.C.; Sersar, Rachida; Saabye, J.

    2014-01-01

    patients referred for a PET/CT were injected with either [18F]-FDG or [18F]-NaF and imaged on PET/CT (Biograph TruePoint/mCT, Siemens) and PET/MRI (mMR, Siemens) following a standard single-injection, dual-imaging clinical WB-protocol. Routine MR-AC was based on in-/opposed-phase MR imaging (orgMR-AC). PET...... and then investigate different strategies to account for bone tissue in clinical PET/MR imaging. To this purpose, bone tissue representation was extracted from separate CT images, and different bone representations were simulated from hypothetically derived MR-based bone classifications. Methods: Twenty oncology.......3%) and lowest for spongCT (–2.2%, range: 0.0% to –13.7%). Conclusions: In PET/MR imaging using standard MR-AC PET uptake values in soft lesions and bone lesions are underestimated by about 10%. In individual patients this bias can be as high as 22%, which is significant during clinical follow-up exams. If bone...

  14. PET image reconstruction: mean, variance, and optimal minimax criterion

    International Nuclear Information System (INIS)

    Liu, Huafeng; Guo, Min; Gao, Fei; Shi, Pengcheng; Xue, Liying; Nie, Jing

    2015-01-01

    Given the noise nature of positron emission tomography (PET) measurements, it is critical to know the image quality and reliability as well as expected radioactivity map (mean image) for both qualitative interpretation and quantitative analysis. While existing efforts have often been devoted to providing only the reconstructed mean image, we present a unified framework for joint estimation of the mean and corresponding variance of the radioactivity map based on an efficient optimal min–max criterion. The proposed framework formulates the PET image reconstruction problem to be a transformation from system uncertainties to estimation errors, where the minimax criterion is adopted to minimize the estimation errors with possibly maximized system uncertainties. The estimation errors, in the form of a covariance matrix, express the measurement uncertainties in a complete way. The framework is then optimized by ∞-norm optimization and solved with the corresponding H ∞ filter. Unlike conventional statistical reconstruction algorithms, that rely on the statistical modeling methods of the measurement data or noise, the proposed joint estimation stands from the point of view of signal energies and can handle from imperfect statistical assumptions to even no a priori statistical assumptions. The performance and accuracy of reconstructed mean and variance images are validated using Monte Carlo simulations. Experiments on phantom scans with a small animal PET scanner and real patient scans are also conducted for assessment of clinical potential. (paper)

  15. Evaluation of GMI and PMI diffeomorphic‐based demons algorithms for aligning PET and CT Images

    Science.gov (United States)

    Yang, Juan; Zhang, You; Yin, Yong

    2015-01-01

    Fusion of anatomic information in computed tomography (CT) and functional information in F18‐FDG positron emission tomography (PET) is crucial for accurate differentiation of tumor from benign masses, designing radiotherapy treatment plan and staging of cancer. Although current PET and CT images can be acquired from combined F18‐FDG PET/CT scanner, the two acquisitions are scanned separately and take a long time, which may induce potential positional errors in global and local caused by respiratory motion or organ peristalsis. So registration (alignment) of whole‐body PET and CT images is a prerequisite for their meaningful fusion. The purpose of this study was to assess the performance of two multimodal registration algorithms for aligning PET and CT images. The proposed gradient of mutual information (GMI)‐based demons algorithm, which incorporated the GMI between two images as an external force to facilitate the alignment, was compared with the point‐wise mutual information (PMI) diffeomorphic‐based demons algorithm whose external force was modified by replacing the image intensity difference in diffeomorphic demons algorithm with the PMI to make it appropriate for multimodal image registration. Eight patients with esophageal cancer(s) were enrolled in this IRB‐approved study. Whole‐body PET and CT images were acquired from a combined F18‐FDG PET/CT scanner for each patient. The modified Hausdorff distance (dMH) was used to evaluate the registration accuracy of the two algorithms. Of all patients, the mean values and standard deviations (SDs) of dMH were 6.65 (± 1.90) voxels and 6.01 (± 1.90) after the GMI‐based demons and the PMI diffeomorphic‐based demons registration algorithms respectively. Preliminary results on oncological patients showed that the respiratory motion and organ peristalsis in PET/CT esophageal images could not be neglected, although a combined F18‐FDG PET/CT scanner was used for image acquisition. The PMI

  16. Principles of Simultaneous PET/MR Imaging.

    Science.gov (United States)

    Catana, Ciprian

    2017-05-01

    Combined PET/MR imaging scanners capable of acquiring simultaneously the complementary information provided by the 2 imaging modalities are now available for human use. After addressing the hardware challenges for integrating the 2 imaging modalities, most of the efforts in the field have focused on developing MR-based attenuation correction methods for neurologic and whole-body applications, implementing approaches for improving one modality by using the data provided by the other and exploring research and clinical applications that could benefit from the synergistic use of the multimodal data. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Motion-compensated PET image reconstruction with respiratory-matched attenuation correction using two low-dose inhale and exhale CT images

    International Nuclear Information System (INIS)

    Nam, Woo Hyun; Ahn, Il Jun; Ra, Jong Beom; Kim, Kyeong Min; Kim, Byung Il

    2013-01-01

    Positron emission tomography (PET) is widely used for diagnosis and follow up assessment of radiotherapy. However, thoracic and abdominal PET suffers from false staging and incorrect quantification of the radioactive uptake of lesion(s) due to respiratory motion. Furthermore, respiratory motion-induced mismatch between a computed tomography (CT) attenuation map and PET data often leads to significant artifacts in the reconstructed PET image. To solve these problems, we propose a unified framework for respiratory-matched attenuation correction and motion compensation of respiratory-gated PET. For the attenuation correction, the proposed algorithm manipulates a 4D CT image virtually generated from two low-dose inhale and exhale CT images, rather than a real 4D CT image which significantly increases the radiation burden on a patient. It also utilizes CT-driven motion fields for motion compensation. To realize the proposed algorithm, we propose an improved region-based approach for non-rigid registration between body CT images, and we suggest a selection scheme of 3D CT images that are respiratory-matched to each respiratory-gated sinogram. In this work, the proposed algorithm was evaluated qualitatively and quantitatively by using patient datasets including lung and/or liver lesion(s). Experimental results show that the method can provide much clearer organ boundaries and more accurate lesion information than existing algorithms by utilizing two low-dose CT images. (paper)

  18. Improving PET spatial resolution and detectability for prostate cancer imaging

    International Nuclear Information System (INIS)

    Bal, H; Guerin, L; Casey, M E; Conti, M; Eriksson, L; Michel, C; Fanti, S; Pettinato, C; Adler, S; Choyke, P

    2014-01-01

    Prostate cancer, one of the most common forms of cancer among men, can benefit from recent improvements in positron emission tomography (PET) technology. In particular, better spatial resolution, lower noise and higher detectability of small lesions could be greatly beneficial for early diagnosis and could provide a strong support for guiding biopsy and surgery. In this article, the impact of improved PET instrumentation with superior spatial resolution and high sensitivity are discussed, together with the latest development in PET technology: resolution recovery and time-of-flight reconstruction. Using simulated cancer lesions, inserted in clinical PET images obtained with conventional protocols, we show that visual identification of the lesions and detectability via numerical observers can already be improved using state of the art PET reconstruction methods. This was achieved using both resolution recovery and time-of-flight reconstruction, and a high resolution image with 2 mm pixel size. Channelized Hotelling numerical observers showed an increase in the area under the LROC curve from 0.52 to 0.58. In addition, a relationship between the simulated input activity and the area under the LROC curve showed that the minimum detectable activity was reduced by more than 23%. (paper)

  19. Effect of glucose level on brain FDG-PET images

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In Young; Lee, Yong Ki; Ahn, Sung Min [Dept. of Radiological Science, Gachon University, Seongnam (Korea, Republic of)

    2017-06-15

    In addition to tumors, normal tissues, such as the brain and myocardium can intake {sup 18}F-FDG, and the amount of {sup 18}F-FDG intake by normal tissues can be altered by the surrounding environment. Therefore, a process is necessary during which the contrasts of the tumor and normal tissues can be enhanced. Thus, this study examines the effects of glucose levels on FDG PET images of brain tissues, which features high glucose activity at all times, in small animals. Micro PET scan was performed on fourteen mice after injecting {sup 18}F-FDG. The images were compared in relation to fasting. The findings showed that the mean SUV value w as 0 .84 higher in fasted mice than in non-fasted mice. During observation, the images from non-fasted mice showed high accumulation in organs other than the brain with increased surrounding noise. In addition, compared to the non-fasted mice, the fasted mice showed higher early intake and curve increase. The findings of this study suggest that fasting is important in assessing brain functions in brain PET using {sup 18}F-FDG. Additional studies to investigate whether caffeine levels and other preprocessing items have an impact on the acquired images would contribute to reducing radiation exposure in patients.

  20. Effect of glucose level on brain FDG-PET images

    International Nuclear Information System (INIS)

    Kim, In Young; Lee, Yong Ki; Ahn, Sung Min

    2017-01-01

    In addition to tumors, normal tissues, such as the brain and myocardium can intake 18 F-FDG, and the amount of 18 F-FDG intake by normal tissues can be altered by the surrounding environment. Therefore, a process is necessary during which the contrasts of the tumor and normal tissues can be enhanced. Thus, this study examines the effects of glucose levels on FDG PET images of brain tissues, which features high glucose activity at all times, in small animals. Micro PET scan was performed on fourteen mice after injecting 18 F-FDG. The images were compared in relation to fasting. The findings showed that the mean SUV value w as 0 .84 higher in fasted mice than in non-fasted mice. During observation, the images from non-fasted mice showed high accumulation in organs other than the brain with increased surrounding noise. In addition, compared to the non-fasted mice, the fasted mice showed higher early intake and curve increase. The findings of this study suggest that fasting is important in assessing brain functions in brain PET using 18 F-FDG. Additional studies to investigate whether caffeine levels and other preprocessing items have an impact on the acquired images would contribute to reducing radiation exposure in patients

  1. Molecular Imaging Challenges With PET

    CERN Document Server

    Lecoq, P

    2010-01-01

    The future trends in molecular imaging and associated challenges for in-vivo functional imaging are illustrated on the basis of a few examples, such as atherosclerosis vulnerable plaques imaging or stem cells tracking. A set of parameters are derived to define the specifications of a new generation of in-vivo imaging devices in terms of sensitivity, spatial resolution and signal-to-noise ratio. The limitations of strategies used in present PET scanners are discussed and new approaches are proposed taking advantage of recent progress on materials, photodetectors and readout electronics. A special focus is put on metamaterials, as a new approach to bring more functionality to detection devices. It is shown that the route is now open towards a fully digital detector head with very high photon counting capability over a large energy range, excellent timing precision and possibility of imaging the energy deposition process.

  2. Motion correction in simultaneous PET/MR brain imaging using sparsely sampled MR navigators

    DEFF Research Database (Denmark)

    Keller, Sune H; Hansen, Casper; Hansen, Christian

    2015-01-01

    BACKGROUND: We present a study performing motion correction (MC) of PET using MR navigators sampled between other protocolled MR sequences during simultaneous PET/MR brain scanning with the purpose of evaluating its clinical feasibility and the potential improvement of image quality. FINDINGS......: Twenty-nine human subjects had a 30-min [(11)C]-PiB PET scan with simultaneous MR including 3D navigators sampled at six time points, which were used to correct the PET image for rigid head motion. Five subjects with motion greater than 4 mm were reconstructed into six frames (one for each navigator...

  3. Targeting post-infarct inflammation by PET imaging: comparison of 68Ga-citrate and 68Ga-DOTATATE with 18F-FDG in a mouse model

    International Nuclear Information System (INIS)

    Thackeray, James T.; Bankstahl, Jens P.; Walte, Almut; Wittneben, Alexander; Bengel, Frank M.; Wang, Yong; Korf-Klingebiel, Mortimer; Wollert, Kai C.

    2015-01-01

    Imaging of inflammation early after myocardial infarction (MI) is a promising approach to the guidance of novel molecular interventions that support endogenous healing processes. 18 F-FDG PET has been used, but may be complicated by physiological myocyte uptake. We evaluated the potential of two alternative imaging targets: lactoferrin binding by 68 Ga-citrate and somatostatin receptor binding by 68 Ga-DOTATATE. C57Bl/6 mice underwent permanent coronary artery ligation. Serial PET imaging was performed 3 - 7 days after MI using 68 Ga-citrate, 68 Ga-DOTATATE, or 18 F-FDG with ketamine/xylazine suppression of myocyte glucose uptake. Myocardial perfusion was evaluated by 13 N-ammonia PET and cardiac geometry by contrast-enhanced ECG-gated CT. Mice exhibited a perfusion defect of 30 - 40 % (of the total left ventricle) with apical anterolateral wall akinesia and thinning on day 7 after MI. 18 F-FDG with ketamine/xylazine suppression demonstrated distinct uptake in the infarct region, as well as in the border zone and remote myocardium. The myocardial standardized uptake value in MI mice was significantly higher than in healthy mice under ketamine/xylazine anaesthesia (1.9 ± 0.4 vs. 1.0 ± 0.1). 68 Ga images exhibited high blood pool activity with no specific myocardial uptake up to 90 min after injection (tissue-to-blood contrast 0.9). 68 Ga-DOTATATE was rapidly cleared from the blood, but myocardial SUV was very low (0.10 ± 0.03). Neither 68 Ga nor 68 Ga-DOTATATE is a useful alternative to 18 F-FDG for PET imaging of myocardial inflammation after MI in mice. Among the three tested approaches, 18 F-FDG with ketamine/xylazine suppression of cardiomyocyte uptake remains the most practical imaging marker of post-infarct inflammation. (orig.)

  4. Low-dose myocardial blood flow imaging using 82Rb-PET (RUBILOW 2.0)

    DEFF Research Database (Denmark)

    Hoff, Camilla Molich; Tolbod, Lars Poulsen; Harms, Hans

    2017-01-01

    Aim: Relative and absolute measures of myocardial blood flow (MBF) can be derived from a 82Rb PET/CT scan using list mode data to extract static, gated and dynamic PET series. High doses of 82Rb are used to maximize image quality in especially static images. High doses require large eluate volumes......, may degrade scanner dead time performance at first pass and decreases generator lifetime. Lower doses will expand the availability of 82Rb PET/CT and lower doses to personnel and patients. The aim of the current study was to examine MBF with a low dose (LD) 82Rb protocol compared to the institution......’s standard (STD) protocol. Methods: Twenty-one patients referred to 82Rb PET were included in the study. Patients were examined during rest and stress with repeated LD (740 MBq) and STD dose (1110 MBq) Rb-PET during the same imaging session. Regional and global rest and stress MBF values, total perfusion...

  5. Research progress in radiolabeling imaging mechanism and clinical applications of "1"8F-FDG

    International Nuclear Information System (INIS)

    Zhai Shizhen; Yang Zhi; Du Jin

    2011-01-01

    PET/CT is one of the most advanced technologies contemporarily, achieving the combination of anatomical imaging and functional imaging. "1"8F-FDG is the most important positron radiopharmaceutical, which was used over 95% in total PET/CT imaging. FDG- PET has been extensively used in diagnosis of several kinds of diseases such as tumor, cardiac disease and epilepsy. The present review provides the history, the quality control, the imaging mechanisms as well as the research progress of the clinical applications of "1"8F-FDG. (authors)

  6. Diagnostic value of rest and stress gated 82Rb PET myocardial perfusion imaging using quantitative software

    International Nuclear Information System (INIS)

    Shi Hongcheng; Gu Yusen; Liu Wenguan; Zhu Weimin; Halkar, R.K.; Santana, C.A.; Feng Yusheng

    2008-01-01

    Objective: Gated myocardial perfusion imaging (MPI) is regularly performed using SPECT. More recently, gated 82 Rb MPI has been used to assess left ventricular myocardial perfusion and function with new generation PET scanners. The objective of this study was to evaluate the value of rest and stress gated 82 Rb PET myocardial perfusion imaging and to determine whether the quantitative technique in- creased the confidence level of the interpreters. Methods: Thirty-two patients underwent rest and adenosine stress gated 82 Pb PET MPI. Emory Cardiac Toolbox quantitative software was used for processing and inter-predation. Left ventricular ejection fraction (LVEF), end-diastolic, end-systolic and transient ischemia dilation ratio were automatically generated. Three interpreters (nuclear medicine doctors) independently reviewed the studies. Visual scoring (1-5 scales: excellent, good, unsure, poor, uninterpretable) was used to assess the overall quality of the gated images and the added confidence level of interpretation. Visual assessment of the LVEF was compared to the automatically generated LVEF. Comparison between the visual assessment and software generated was graded on a 1- 5 scales (helpful, probably helpful, unsure, probably not helpful, definitely not helpful). The analysed items were divided into two groups (favorable group and negative group). The percentage and 95% confidence intervals of each group were calculated. Results: A total of 192 gated studies were evaluated (64 gated x 3 interpreters ). The overall quality of the gated images was good [excellent 40.1% (77/192), good 43.2% (83/192), unsure 3.1% (6/192), poor 13.6% (26/192), uninterpretable 0]. The 95% confidence intervals of good and excellent quality range from 78.1% to 88.6%. The interpreter's agreed with the automated LVEF on 85.4% of the gated images [agree 76.6% (147/192), probably agree 8.8% (17/192), unsure 3.1% (6/192), probably disagree 8.8% (17/192), disagree 2.6% (5/192)]. And its 95

  7. PET imaging biomarkers in head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Differding, Sarah; Gregoire, Vincent [Universite Catholique de Louvain, St-Luc University Hospital, Department of Radiation Oncology, and Center for Molecular Imaging, Radiotherapy and Oncology (MIRO), Institut de Recherche Experimentale et Clinique (IREC), Brussels (Belgium); Hanin, Francois-Xavier [Universite Catholique de Louvain, St-Luc University Hospital, Department of Nuclear Medicine, and Center for Molecular Imaging, Radiotherapy and Oncology (MIRO), Institut de Recherche Experimentale et Clinique (IREC), Brussels (Belgium)

    2015-04-01

    In locally advanced head and neck squamous cell carcinoma (HNSCC), the role of imaging becomes more and more critical in the management process. In this framework, molecular imaging techniques such as PET allow noninvasive assessment of a range of tumour biomarkers such as metabolism, hypoxia and proliferation, which can serve different purposes. First, in a pretreatment setting they can influence therapy selection strategies and target delineation for radiation therapy. Second, their predictive and/or prognostic value could help enhance the therapeutic ratio in the management of HNSCC. Third, treatment modification can be performed through the generation of a molecular-based heterogeneous dose distribution with dose escalation to the most resistant parts of the tumour, a concept known as dose painting. Fourth, they are increasingly becoming a tool for monitoring response to therapy. In this review, PET imaging biomarkers used in the routine management of HNSCC or under investigation are discussed. (orig.)

  8. FDG and FDG-labelled leucocyte PET/CT in the imaging of prosthetic joint infection

    Energy Technology Data Exchange (ETDEWEB)

    Aksoy, Sabire Yilmaz; Asa, Sertac; Ozhan, Meftune; Sager, M.S.; Halac, Metin; Kabasakal, Levent; Soenmezoglu, Kerim; Kanmaz, Bedii [University of Istanbul, Department of Nuclear Medicine, Cerrahpasa Medical Faculty, Aksaray, Istanbul (Turkey); Ocak, Meltem [University of Istanbul, Department of Pharmaceutical Technology, Faculty of Pharmacy, Istanbul (Turkey); Erkan, Melih Engin [Duzce University School of Medicine, Department of Nuclear Medicine, Duzce (Turkey)

    2014-03-15

    The demand for arthroplasty is rapidly growing as a result of the ageing of the population. Although complications such as heterotrophic ossification, fracture and dislocation are relatively rare, differentiating aseptic loosening, the most common complication of arthroplasty from infection, is a major challenge for clinicians. Radionuclide imaging is currently the imaging modality of choice since it is not affected by orthopaedic hardware. Whereas FDG PET/CT imaging has been widely used in periprosthetic infection, it cannot discriminate aseptic from septic inflammation. In this study we aimed to evaluate the role of FDG PET/CT and FDG-labelled leucocyte PET/CT in the diagnosis of periprosthetic infection. Of 54 patients with painful joint arthroplasty who were imaged by FDG PET/CT for diagnosis of periprosthetic infection examined, 46 (36 women, 10 men; mean age 61.04 ± 12.2 years, range 32 - 89 years) with 54 painful joint prostheses (19 hip, 35 knee) with grade 2 (above liver uptake) FDG accumulation on FDG PET/CT were included in the study and these 46 patients also underwent FDG-labelled leucocyte PET/CT. Final diagnoses were made by histopathological-microbiological culture or clinical follow-up. The final diagnosis showed infection in 15 (28 %) and aseptic loosening in 39 (72 %) of the 54 prostheses. FDG PET/CT was found to have a positive predictive value of 28 % (15/54). Since patients with no FDG uptake on FDG PET/CT were excluded from the study, the sensitivity, specificity, negative predictive value and accuracy could not be calculated. The sensitivity, specificity, and positive and negative predictive values of FDG-labelled leucocyte PET/CT were 93.3 % (14/15), 97.4 % (38/39), 93.3 % and 97.4 %, respectively. Since FDG is not specific to infection, the specificity of FDG PET/CT was very low. FDG-labelled leucocyte PET/CT with its high specificity may be a useful method and better than labelled leucocyte scintigraphy in periprosthetic infection

  9. Novel axolotl cardiac function analysis method using magnetic resonance imaging

    NARCIS (Netherlands)

    Sanches, Pedro Gomes; Op 't Veld, Roel C.; de Graaf, Wolter; Strijkers, Gustav J.; Grüll, Holger

    2017-01-01

    The salamander axolotl is capable of complete regeneration of amputated heart tissue. However, non-invasive imaging tools for assessing its cardiac function were so far not employed. In this study, cardiac magnetic resonance imaging is introduced as a non-invasive technique to image heart function

  10. Novel axolotl cardiac function analysis method using magnetic resonance imaging

    NARCIS (Netherlands)

    Sanches, P.G.; Op ‘t Veld, R.C.; de Graaf, W.; Strijkers, G.J.; Grüll, H.

    2017-01-01

    The salamander axolotl is capable of complete regeneration of amputated heart tissue. However, non-invasive imaging tools for assessing its cardiac function were so far not employed. In this study, cardiac magnetic resonance imaging is introduced as a noninvasive technique to image heart function of

  11. Application of the random field theory in PET imaging - injection dose optimization

    Czech Academy of Sciences Publication Activity Database

    Dvořák, Jiří; Boldyš, Jiří; Skopalová, M.; Bělohlávek, O.

    2013-01-01

    Roč. 49, č. 2 (2013), s. 280-300 ISSN 0023-5954 R&D Projects: GA MŠk 1M0572 Institutional support: RVO:67985556 Keywords : random field theory * Euler characteristic * PET imaging * PET image quality Subject RIV: BD - Theory of Information Impact factor: 0.563, year: 2013 http://library.utia.cas.cz/separaty/2013/ZOI/boldys-0397176.pdf

  12. Acquiring additional delayed PET images improves sensitivity and specificity in oncology cases

    International Nuclear Information System (INIS)

    Lamki, L.M.; Barron, B.J.; Mullani, N.; Joseph, U.; Ehert, E.

    2002-01-01

    Aim: This study looked into utility of acquiring PET images at 2-3 hours in addition to the standard whole body PET done at 1-hour after FDG injection in certain oncology cases. The objective is to evaluate whether the delayed additional images can decipher equivocal foci of FDG accumulation commonly seen in oncology patients. Typical example is the bowel activity that moves with time. Materials and Methods: PET protocol at our Institution in patients with colon Cancer, Pancreas Ca, Ovarian Ca and Breast Ca include a whole body PET (6-7 bed positions) done at 1-hour after 15 mCi F-18-FDG followed by select limited area PET scan (typically 2 bed stops over the area of interest) at 2-3 hours. Acquisition was undertaken on Siemens ECAT-EXACT Camera - 2-D acquisition and 8 mins. per bed position (5 mins. Emission and 3 mins. Transmission), 16.3 cm FOV and then Iterative Reconstruction. Results: Analysis of the first 115 patients who had additional delayed images resulted in 80% of patients where delayed images helped in interpretation. In 70% of these, delayed images helped in identifying physiological structures, e.g., ureters, bowel, blood vessels and muscles versus pathology. In 25%, they actually helped in identifying malignancy, e.g. more definite FDG accumulation. Almost all helped to boost the confidence of the reader. The contribution was mainly in differentiating bowel and ureter activity from cancer in the abdomen, as these change position with time. In case of pancreas and breast cancer, delayed images contributed in clarifying tumor metabolic activity as well. Inflammation and motion artifacts could also be better defined and so was muscle uptake. Conclusion: (1) Additional delayed PET imaging is very helpful in certain cancers in identifying more lesions and avoiding pitfalls. (2) They can yield higher sensitivity and specificity for colon, ovarian, breast and pancreas cancers. (3) Identification of physiologic structures and differentiation of these from

  13. Derivation of the scan time requirement for maintaining a consistent PET image quality

    International Nuclear Information System (INIS)

    Kim, Jin Su; Lee, Jae Sung; Kim, Seok-Ki

    2015-01-01

    Objectives: the image quality of PET for larger patients is relatively poor, even though the injection dose is optimized considering the NECR characteristics of the PET scanner. This poor image quality is due to the lower level of maximum NECR that can be achieved in these large patients. The aim of this study was to optimize the PET scan time to obtain a consistent PET image quality regardless of the body size, based on the relationship between the patient specific NECR (pNECR) and body weight. Methods: eighty patients (M/F=53/27, body weight: 059 ± 1 kg) underwent whole-body FDG PET scans using a Philips GEMINI GS PET/CT scanner after an injection of 0.14 mCi/kg FDG. The relationship between the scatter fraction (SF) and body weight was determined by repeated Monte Carlo simulations using a NEMA scatter phantom, the size of which varied according to the relationship between the abdominal circumference and body weight. Using this information, the pNECR was calculated from the prompt and delayed PET sinograms to obtain the prediction equation of NECR vs. body weight. The time scaling factor (F TS ) for the scan duration was finally derived to make PET images with equivalent SNR levels. Results: the SF and NECR had the following nonlinear relationships with the body weight: SF=0.15 ⋅ body weight 0.3 and NECR = 421.36 (body weight) −0.84 . The equation derived for F TS was 0.01⋅ body weight + 0.2, which means that, for example, a 120-kg person should be scanned 1.8 times longer than a 70 kg person, or the scan time for a 40-kg person can be reduced by 30%. Conclusion: the equation of the relative time demand derived in this study will be useful for maintaining consistent PET image quality in clinics

  14. MR imaging versus PET/CT for evaluation of pancreatic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Belião, Sara, E-mail: sara.beliao@clix.pt [Department of Radiology Hospital S. Francisco Xavier, Estrada do Forte do Alto do Duque, 1495-005 Lisbon (Portugal); Ferreira, Alexandra, E-mail: alexandratavaresferreira@gmail.com [Department of Radiology, Hospital D. Estefânia, Rua Jacinta Marto, 1169-045 Lisbon (Portugal); Vierasu, Irina, E-mail: Ortansa-Irina.Vierasu@ulb.ac.be [Service de Médecine Nucléaire, Route de Lennik 808, 1070 Brussels (Belgium); Blocklet, Didier, E-mail: dblockle@ulb.ac.be [Service de Médecine Nucléaire, Route de Lennik 808, 1070 Brussels (Belgium); Goldman, Serge, E-mail: petscan@ulb.ac.be [Service de Médecine Nucléaire, Route de Lennik 808, 1070 Brussels (Belgium); Metens, Thierry, E-mail: tmetens@ulb.ac.be [Service de Radiologie – Imagerie par Resonance Magnétique, Route de Lennik 808, 1070 Brussels (Belgium); Matos, Celso, E-mail: cmatos@ulb.ac.be [Service de Radiologie – Imagerie par Resonance Magnétique, Route de Lennik 808, 1070 Brussels (Belgium)

    2012-10-15

    Purpose: To retrospectively determine the diagnostic accuracy of magnetic resonance imaging (MRI) and combined positron emission tomography/computed tomography (PET/CT) in the differential diagnosis of benign and malignant pancreatic lesions. Materials and methods: Twenty-seven patients (15 women/12 men, mean age 56.5 years) with MR imaging and PET/CT studies performed to differentiate benign and malignant pancreatic lesions were identified between October 2008 and October 2010. Both MR and PET/CT data sets were retrospectively and blindly evaluated by two independent readers (4 readers total) with different degrees of experience, using a visual five-point score system. The results were correlated with final diagnosis obtained by histopathology. Results: 17 patients had malignant diseases and 10 patients had benign diseases. Depending on the observer, the sensitivity, specificity, positive predictive value and negative predictive value of MRI varied between 88–94%, 50–80%, 75–89% and 71–89% respectively. Sensitivities, specificities, positive predictive values and negative predictive values of PET/CT were 73%, 56%, 73% and 56% respectively. The diagnostic accuracy of MR for the differential diagnosis of pancreatic lesions was 74–89%, compared with 67% for PET/CT. The weighted Cohen's kappa coefficient was 0.47 at MR and 0.53 at PET/CT. Conclusion: MRI achieved higher sensitivity and specificity in the differential diagnosis of pancreatic lesions.

  15. Anatomy assisted PET image reconstruction incorporating multi-resolution joint entropy

    International Nuclear Information System (INIS)

    Tang, Jing; Rahmim, Arman

    2015-01-01

    A promising approach in PET image reconstruction is to incorporate high resolution anatomical information (measured from MR or CT) taking the anato-functional similarity measures such as mutual information or joint entropy (JE) as the prior. These similarity measures only classify voxels based on intensity values, while neglecting structural spatial information. In this work, we developed an anatomy-assisted maximum a posteriori (MAP) reconstruction algorithm wherein the JE measure is supplied by spatial information generated using wavelet multi-resolution analysis. The proposed wavelet-based JE (WJE) MAP algorithm involves calculation of derivatives of the subband JE measures with respect to individual PET image voxel intensities, which we have shown can be computed very similarly to how the inverse wavelet transform is implemented. We performed a simulation study with the BrainWeb phantom creating PET data corresponding to different noise levels. Realistically simulated T1-weighted MR images provided by BrainWeb modeling were applied in the anatomy-assisted reconstruction with the WJE-MAP algorithm and the intensity-only JE-MAP algorithm. Quantitative analysis showed that the WJE-MAP algorithm performed similarly to the JE-MAP algorithm at low noise level in the gray matter (GM) and white matter (WM) regions in terms of noise versus bias tradeoff. When noise increased to medium level in the simulated data, the WJE-MAP algorithm started to surpass the JE-MAP algorithm in the GM region, which is less uniform with smaller isolated structures compared to the WM region. In the high noise level simulation, the WJE-MAP algorithm presented clear improvement over the JE-MAP algorithm in both the GM and WM regions. In addition to the simulation study, we applied the reconstruction algorithms to real patient studies involving DPA-173 PET data and Florbetapir PET data with corresponding T1-MPRAGE MRI images. Compared to the intensity-only JE-MAP algorithm, the WJE

  16. Anatomy assisted PET image reconstruction incorporating multi-resolution joint entropy

    Science.gov (United States)

    Tang, Jing; Rahmim, Arman

    2015-01-01

    A promising approach in PET image reconstruction is to incorporate high resolution anatomical information (measured from MR or CT) taking the anato-functional similarity measures such as mutual information or joint entropy (JE) as the prior. These similarity measures only classify voxels based on intensity values, while neglecting structural spatial information. In this work, we developed an anatomy-assisted maximum a posteriori (MAP) reconstruction algorithm wherein the JE measure is supplied by spatial information generated using wavelet multi-resolution analysis. The proposed wavelet-based JE (WJE) MAP algorithm involves calculation of derivatives of the subband JE measures with respect to individual PET image voxel intensities, which we have shown can be computed very similarly to how the inverse wavelet transform is implemented. We performed a simulation study with the BrainWeb phantom creating PET data corresponding to different noise levels. Realistically simulated T1-weighted MR images provided by BrainWeb modeling were applied in the anatomy-assisted reconstruction with the WJE-MAP algorithm and the intensity-only JE-MAP algorithm. Quantitative analysis showed that the WJE-MAP algorithm performed similarly to the JE-MAP algorithm at low noise level in the gray matter (GM) and white matter (WM) regions in terms of noise versus bias tradeoff. When noise increased to medium level in the simulated data, the WJE-MAP algorithm started to surpass the JE-MAP algorithm in the GM region, which is less uniform with smaller isolated structures compared to the WM region. In the high noise level simulation, the WJE-MAP algorithm presented clear improvement over the JE-MAP algorithm in both the GM and WM regions. In addition to the simulation study, we applied the reconstruction algorithms to real patient studies involving DPA-173 PET data and Florbetapir PET data with corresponding T1-MPRAGE MRI images. Compared to the intensity-only JE-MAP algorithm, the WJE

  17. Dual gated PET/CT imaging of small targets of the heart: method description and testing with a dynamic heart phantom.

    Science.gov (United States)

    Kokki, Tommi; Sipilä, Hannu T; Teräs, Mika; Noponen, Tommi; Durand-Schaefer, Nicolas; Klén, Riku; Knuuti, Juhani

    2010-01-01

    In PET imaging respiratory and cardiac contraction motions interfere the imaging of heart. The aim was to develop and evaluate dual gating method for improving the detection of small targets of the heart. The method utilizes two independent triggers which are sent periodically into list mode data based on respiratory and ECG cycles. An algorithm for generating dual gated segments from list mode data was developed. The test measurements showed that rotational and axial movements of point source can be separated spatially to different segments with well-defined borders. The effect of dual gating on detection of small moving targets was tested with a moving heart phantom. Dual gated images showed 51% elimination (3.6 mm out of 7.0 mm) of contraction motion of hot spot (diameter 3 mm) and 70% elimination (14 mm out of 20 mm) of respiratory motion. Averaged activity value of hot spot increases by 89% when comparing to non-gated images. Patient study of suspected cardiac sarcoidosis shows sharper spatial myocardial uptake profile and improved detection of small myocardial structures such as papillary muscles. The dual gating method improves detection of small moving targets in a phantom and it is feasible in clinical situations.

  18. FDG-PET/CT imaging for staging and target volume delineation in conformal radiotherapy of anal carcinoma

    International Nuclear Information System (INIS)

    Krengli, Marco; Inglese, Eugenio; Milia, Maria E; Turri, Lucia; Mones, Eleonora; Bassi, Maria C; Cannillo, Barbara; Deantonio, Letizia; Sacchetti, Gianmauro; Brambilla, Marco

    2010-01-01

    FDG-PET/CT imaging has an emerging role in staging and treatment planning of various tumor locations and a number of literature studies show that also the carcinoma of the anal canal may benefit from this diagnostic approach. We analyzed the potential impact of FDG-PET/CT in stage definition and target volume delineation of patients affected by carcinoma of the anal canal and candidates for curative radiotherapy. Twenty seven patients with biopsy proven anal carcinoma were enrolled. Pathology was squamous cell carcinoma in 20 cases, cloacogenic carcinoma in 3, adenocarcinoma in 2, and basal cell carcinoma in 2. Simulation was performed by PET/CT imaging with patient in treatment position. Gross Tumor Volume (GTV) and Clinical Target Volume (CTV) were drawn on CT and on PET/CT fused images. PET-GTV and PET-CTV were respectively compared to CT-GTV and CT-CTV by Wilcoxon rank test for paired data. PET/CT fused images led to change the stage in 5/27 cases (18.5%): 3 cases from N0 to N2 and 2 from M0 to M1 leading to change the treatment intent from curative to palliative in a case. Based on PET/CT imaging, GTV and CTV contours changed in 15/27 (55.6%) and in 10/27 cases (37.0%) respectively. PET-GTV and PET-CTV resulted significantly smaller than CT-GTV (p = 1.2 × 10 -4 ) and CT-CTV (p = 2.9 × 10 -4 ). PET/CT-GTV and PET/CT-CTV, that were used for clinical purposes, were significantly greater than CT-GTV (p = 6 × 10 -5 ) and CT-CTV (p = 6 × 10 -5 ). FDG-PET/CT has a potential relevant impact in staging and target volume delineation of the carcinoma of the anal canal. Clinical stage variation occurred in 18.5% of cases with change of treatment intent in 3.7%. The GTV and the CTV changed in shape and in size based on PET/CT imaging

  19. Computerized method for evaluating diagnostic image quality of calcified plaque images in cardiac CT: Validation on a physical dynamic cardiac phantom

    Energy Technology Data Exchange (ETDEWEB)

    King, Martin; Rodgers, Zachary; Giger, Maryellen L.; Bardo, Dianna M. E.; Patel, Amit R. [Department of Radiology, Committee on Medical Physics, University of Chicago, 5841 South Maryland Avenue, MC 2026, Chicago, Illinois 60637 (United States); Department of Diagnostic Radiology, Oregon Health and Science University, 3181 Southwest Sam Jackson Park Road, Portland, Oregon 97239 (United States); Department of Medicine, University of Chicago, 5841 South Maryland Avenue, MC 5084, Chicago, Illinois 60637 (United States)

    2010-11-15

    Purpose: In cardiac computed tomography (CT), important clinical indices, such as the coronary calcium score and the percentage of coronary artery stenosis, are often adversely affected by motion artifacts. As a result, the expert observer must decide whether or not to use these indices during image interpretation. Computerized methods potentially can be used to assist in these decisions. In a previous study, an artificial neural network (ANN) regression model provided assessability (image quality) indices of calcified plaque images from the software NCAT phantom that were highly agreeable with those provided by expert observers. The method predicted assessability indices based on computer-extracted features of the plaque. In the current study, the ANN-predicted assessability indices were used to identify calcified plaque images with diagnostic calcium scores (based on mass) from a physical dynamic cardiac phantom. The basic assumption was that better quality images were associated with more accurate calcium scores. Methods: A 64-channel CT scanner was used to obtain 500 calcified plaque images from a physical dynamic cardiac phantom at different heart rates, cardiac phases, and plaque locations. Two expert observers independently provided separate sets of assessability indices for each of these images. Separate sets of ANN-predicted assessability indices tailored to each observer were then generated within the framework of a bootstrap resampling scheme. For each resampling iteration, the absolute calcium score error between the calcium scores of the motion-contaminated plaque image and its corresponding stationary image served as the ground truth in terms of indicating images with diagnostic calcium scores. The performances of the ANN-predicted and observer-assigned indices in identifying images with diagnostic calcium scores were then evaluated using ROC analysis. Results: Assessability indices provided by the first observer and the corresponding ANN performed

  20. Preclinical quantitative MicroPET imaging in evaluation of neuroprotective drug candidates

    International Nuclear Information System (INIS)

    Son, Ji Yeon; Kim, Yu Kyeong; Kim, Ji Sun; Lee, Byung Chul; Kim, Kyeong Min; Choi, Tae Hyun; Cheon, Gi Jeong; Lee, Won Woo; Kim, Sang Eun

    2007-01-01

    Using in vivo molecular imaging with microPET/SPECT has been expected to facilitate drug discovery and development. In this study, we applied quantitative microPET to the preclinical evaluation of the effects of two neuroprotective drug candidates to the nigrostriatal dopaminergic neuronal damage. Fifteen SD rats were divided into three groups. The rats of each group were orally administrated one of neuroprotective candidate; NeuProtec (100mg/kg bid) and SureCero (10mg/kg, qd) or normal saline (0.1ml, qd) for 3 weeks. 6-OHDA was sterotactically placed to the right striatum on eighth day after starting while continuing the medication for additional 14 days. [ 124 I]FP-ClT PET scans were obtained using microPET R4 scanner. The behavioral test by amphetamine-induced rotation and the histological examination after thyrosine hydroxylase (TH) immunohistochemical staining were performed. Different uptake in the lesioned striatum among the groups were demonstrated on [ 124 I]FP-CIT PET images. The rats with NeuProtec showed higher binding in the lesion than controls. No differences were observed in SureCere groups. The FP-CIT uptake in the lesioned striatum was well correlated with the % reduction of TH(+) cells (rho =0.73, p=0.025), and also correlated with rotation test (rho =0.79, p=0.001) [ 124 I]FP-CIT animal PET depicted the neuroprotective effects of NeuProtec to the 6-OHDA neurotoxicity in the rat striatum. No demonstrable effect of SureCero might indicate that inadequate dosage was used in this study. MicroPET imaging with small animal could be a great tool in preclinical evaluation of drug efficacy

  1. Perspectives on Current Training Guidelines for Cardiac Imaging and Recommendations for the Future.

    Science.gov (United States)

    Arrighi, James A; Kilic, Sena; Haines, Philip G

    2018-04-23

    To summarize current training guidelines for cardiac imaging and provide recommendations for future guidelines. The current structure of training in cardiac imaging is largely dictated by modality-specific guidelines. While there has been debate on how to define the advanced cardiac imager for over a decade, a uniform consensus has not emerged. We report the perspectives of three key stakeholders in this debate: a senior faculty member-former fellowship program director, a cardiology fellow, and an academic junior faculty imaging expert. The observations of these stakeholders suggest that there is no consensus on the definition of advanced cardiac imaging, leading to ambiguity in training guidelines. This may have negative impact on recruitment of fellows into cardiac imaging careers. Based on the current status of training in cardiac imaging, the authors suggest that the relevant professional groups reconvene to form a consensus in defining advanced cardiac imaging, in order to guide future revisions of training guidelines.

  2. 64Cu-PSMA-617 PET/CT Imaging of Prostate Adenocarcinoma: First In-Human Studies.

    Science.gov (United States)

    Grubmüller, Bernhard; Baum, Richard P; Capasso, Enza; Singh, Aviral; Ahmadi, Yasaman; Knoll, Peter; Floth, Andreas; Righi, Sergio; Zandieh, Shahin; Meleddu, Carlo; Shariat, Shahrokh F; Klingler, Hans Christoph; Mirzaei, Siroos

    2016-10-07

    The prostate-specific membrane antigen (PSMA) is a cell surface protein, which is overexpressed in nearly all cases of prostate cancer (PCa). PET imaging with 68 Ga-PSMA-HBED-CC has recently found widespread application in the diagnosis of recurrent PCa. In this study, the diagnostic potential of 64 Cu-labeled PSMA ligand (PSMA-617) PET in patients with PCa has been investigated. The study was conducted simultaneously at two nuclear medicine centers, Austria (Vienna, Center 1) and Germany (Bad Berka, Center 2). The patients (n = 29) included in this study were referred for PET (Center 1, 21 patients) or PET/CT (Center 2, 8 patients) imaging with either a high suspicion of recurrent disease or for possible surgical or PSMA radioligand therapy planning. PET images of the whole body were performed at 1 hour p.i. and additional images of the pelvis at 2 hours p.i. In 23 of 29 patients, at least one focus of pathological tracer uptake suspicious for primary disease in the prostate lobe or recurrent disease was detected. Among healthy organs, the salivary glands, kidneys, and liver showed the highest radiotracer uptake. Lesions suspicious for PCa were detected with excellent contrast as early as 1 hour p.i. with high detection rates even at low prostate-specific antigen (PSA) levels. The preliminary results of this study demonstrate the high potential of 64 Cu-PSMA ligand PET/CT imaging in patients with recurrent disease and in the primary staging of selected patients with progressive local disease. The acquired PET images showed an excellent resolution of the detected lesions with very high lesion-to- background contrast. Furthermore, the long half-life of 64 Cu allows distribution of the tracer to clinical PET centers that lack radiochemistry facilities for the preparation of 68 Ga-PSMA ligand (satellite concept).

  3. PET measures of pre- and post-synaptic cardiac beta adrenergic function

    Energy Technology Data Exchange (ETDEWEB)

    Link, Jeanne M.; Stratton, John R.; Levy, Wayne; Poole, Jeanne E.; Shoner, Steven C.; Stuetzle, Werner; Caldwell, James H. E-mail: jcald@u.washington.edu

    2003-11-01

    Positron Emission Tomography was used to measure global and regional cardiac {beta}-adrenergic function in 19 normal subjects and 9 congestive heart failure patients. [{sup 11}C]-meta-hydroxyephedrine was used to image norepinephrine transporter function as an indicator of pre-synaptic function and [{sup 11}C]-CGP12177 was used to measure cell surface {beta}-receptor density as an indicator of post-synaptic function. Pre-synaptic, but not post-synaptic, function was significantly different between normals and CHF patients. Pre-synaptic function was well matched to post-synaptic function in the normal hearts but significantly different and poorly matched in the CHF patients studied. This imaging technique can help us understand regional sympathetic function in cardiac disease.

  4. Structured light 3D tracking system for measuring motions in PET brain imaging

    DEFF Research Database (Denmark)

    Olesen, Oline Vinter; Jørgensen, Morten Rudkjær; Paulsen, Rasmus Reinhold

    2010-01-01

    Patient motion during scanning deteriorates image quality, especially for high resolution PET scanners. A new proposal for a 3D head tracking system for motion correction in high resolution PET brain imaging is set up and demonstrated. A prototype tracking system based on structured light with a ...

  5. Automated interpretation of PET/CT images in patients with lung cancer

    DEFF Research Database (Denmark)

    Gutte, Henrik; Jakobsson, David; Olofsson, Fredrik

    2007-01-01

    cancer. METHODS: A total of 87 patients who underwent PET/CT examinations due to suspected lung cancer comprised the training group. The test group consisted of PET/CT images from 49 patients suspected with lung cancer. The consensus interpretations by two experienced physicians were used as the 'gold...... method measured as the area under the receiver operating characteristic curve, was 0.97 in the test group, with an accuracy of 92%. The sensitivity was 86% at a specificity of 100%. CONCLUSIONS: A completely automated method using artificial neural networks can be used to detect lung cancer......PURPOSE: To develop a completely automated method based on image processing techniques and artificial neural networks for the interpretation of combined [(18)F]fluorodeoxyglucose (FDG) positron emission tomography (PET) and computed tomography (CT) images for the diagnosis and staging of lung...

  6. Poster - 01: LabPET II Pixelated APD-Based PET Scanner for High-Resolution Preclinical Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lecomte, Roger; Arpin, Louis; Beaudoin, Jean-François; Bergeron, Mélanie; Bouchard, Jonathan; Bouziri, Haithem; Cadorette, Jules; Gaudin, Émilie; Jürgensen, Nadia; Koua, Konin Calliste; Trépanier, Pierre-Yves Lauzier; Leroux, Jean-Daniel; Loignon-Houle, Francis; Njejimana, Larissa; Paillé, Maxime; Paulin, Caroline; Pepin, Catherine; Pratte, Jean-François; Samson, Arnaud; Thibaudeau, Christian [Université de Sherbrooke, Université de Sherbrooke, CIMS/CRCHUS, Université de Sherbrooke, Université de Sherbrooke, Université de Sherbrooke, CIMS/CRCHUS, Université de Sherbrooke, Université de Sherbrooke, 3IT, Université de Sherbrooke, Novalgo Inc., Université de Sherbrooke, Université de Sherbrooke, CIMS/CRCHUS, 3IT, Université de Sherbrooke, Université de Sherbrooke, Université de Sherbrooke, Université de Sherbrooke, 3IT, Université de Sherbrooke (Canada); and others

    2016-08-15

    Purpose: LabPET II is a new generation APD-based PET scanner designed to achieve sub-mm spatial resolution using truly pixelated detectors and highly integrated parallel front-end processing electronics. Methods: The basic element uses a 4×8 array of 1.12×1.12 mm{sup 2} Lu{sub 1.9}Y{sub 0.1}SiO{sub 5}:Ce (LYSO) scintillator pixels with one-to-one coupling to a 4×8 pixelated monolithic APD array mounted on a ceramic carrier. Four detector arrays are mounted on a daughter board carrying two flip-chip, 64-channel, mixed-signal, application-specific integrated circuits (ASIC) on the backside interfacing to two detector arrays each. Fully parallel signal processing was implemented in silico by encoding time and energy information using a dual-threshold Time-over-Threshold (ToT) scheme. The self-contained 128-channel detector module was designed as a generic component for ultra-high resolution PET imaging of small to medium-size animals. Results: Energy and timing performance were optimized by carefully setting ToT thresholds to minimize the noise/slope ratio. ToT spectra clearly show resolved 511 keV photopeak and Compton edge with ToT resolution well below 10%. After correction for nonlinear ToT response, energy resolution is typically 24±2% FWHM. Coincidence time resolution between opposing 128-channel modules is below 4 ns FWHM. Initial imaging results demonstrate that 0.8 mm hot spots of a Derenzo phantom can be resolved. Conclusion: A new generation PET scanner featuring truly pixelated detectors was developed and shown to achieve a spatial resolution approaching the physical limit of PET. Future plans are to integrate a small-bore dedicated mouse version of the scanner within a PET/CT platform.

  7. Transforming a Targeted Porphyrin Theranostic Agent into a PET Imaging Probe for Cancer

    Directory of Open Access Journals (Sweden)

    Jiyun Shi, Tracy W.B. Liu, Juan Chen, David Green, David Jaffray, Brian C. Wilson, Fan Wang, Gang Zheng

    2011-01-01

    Full Text Available Porphyrin based photosensitizers are useful agents for photodynamic therapy (PDT and fluorescence imaging of cancer. Porphyrins are also excellent metal chelators forming highly stable metallo-complexes making them efficient delivery vehicles for radioisotopes. Here we investigated the possibility of incorporating 64Cu into a porphyrin-peptide-folate (PPF probe developed previously as folate receptor (FR targeted fluorescent/PDT agent, and evaluated the potential of turning the resulting 64Cu-PPF into a positron emission tomography (PET probe for cancer imaging. Noninvasive PET imaging followed by radioassay evaluated the tumor accumulation, pharmacokinetics and biodistribution of 64Cu-PPF. 64Cu-PPF uptake in FR-positive tumors was visible on small-animal PET images with high tumor-to-muscle ratio (8.88 ± 3.60 observed after 24 h. Competitive blocking studies confirmed the FR-mediated tracer uptake by the tumor. The ease of efficient 64Cu-radiolabeling of PPF while retaining its favorable biodistribution, pharmacokinetics and selective tumor uptake, provides a robust strategy to transform tumor-targeted porphyrin-based photosensitizers into PET imaging probes.

  8. Clinical cardiac positron emission tomography: State of the art

    International Nuclear Information System (INIS)

    Gould, K.L.

    1991-01-01

    Cardiac positron emission tomography (PET) has evolved rapidly from a relatively esoteric research tool into clinical applications providing unique, quantitative information on myocardial perfusion, metabolism, and cell membrane function and having a potentially significant impact on cardiovascular medicine. Although there are many different positron radionuclides for imaging diverse myocardial behavior, three radionuclides have reached accepted clinical utility. Cardiac PET using nitrogen-13-ammonia, rubidium-82, and fluoro-18-deoxyglucose has proved accurate and definitive in multiple university and private-practice sites for diagnosing and assessing severity and location of coronary artery disease in symptomatic or asymptomatic patients, for identifying injured but viable myocardium potentially salvageable by revascularization, and for ruling out clinically significant coronary artery stenosis with a high specificity in patients who might otherwise undergo coronary arteriography to document the absence of significant disease. 89 references

  9. Lung PET scan

    Science.gov (United States)

    ... Chest PET scan; Lung positron emission tomography; PET - chest; PET - lung; PET - tumor imaging; ... Grainger & Allison's Diagnostic Radiology: A Textbook of Medical Imaging . 6th ed. Philadelphia, ...

  10. Peritoneal Lymphomatosis Imaged by F-18 FDG PET/CT

    International Nuclear Information System (INIS)

    Park, Eun Kyung; Lee, Se Ryeon; Kim, Young Chul; Oh, Sun Young; Choe, Jae Gol

    2010-01-01

    Peritoneal lymphomatosis is uncommon, but when encountered is associated with aggressive histological subtypes of high-grade lymphoma, such as small-cell, large-cell, mixed large and small cell, non-cleaved, lymphoblastic Burkitt-like, and diffuse large B-cell lymphomas. The CT findings of peritoneal lymphomatosis are linear or nodular peritoneal thickening, retroperitoneal lymphadenopathy, omental and mesenteric involvement with streak-like infiltrations or a bulky mass, bowel wall thickening, hepatosplenomegaly, and ascites. The authors reports report the first FDG PET/CT images of diffuse large B-cell lymphoma of small bowel origin associated with peritoneal lymphomatosis in a 69-year-old man. The lesions demonstrated intense FDG uptake in PET/CT images.

  11. Cardiac MR imaging: Comparison with echocardiography and dynamic CT

    International Nuclear Information System (INIS)

    Colletti, P.M.; Norris, S.; Raval, J.; Boswell, W.; Lee, K.; Ralls, P.; Haywood, J.; Halls, J.

    1986-01-01

    The authors compared gated cardiac MR imaging with two-dimensional and Doppler echocardiography and dynamic CT. Gated cardiac MR imaging (VISTA unit, 0.5 T) was performed in 55 patients with a variety of conditions. Accuracy of diagnosis was compared. CT showed arterial, valvular, and pericardial calcifications not seen on MR imaging. Many lesions were seen as well on CT as on MR imaging. Two-dimensional echocardiography was superior in demonstrating wall motion and valvular disease. MR imaging was superior in demonstrating myocardial structures

  12. In-beam PET imaging for on-line adaptive proton therapy: an initial phantom study

    Science.gov (United States)

    Shao, Yiping; Sun, Xishan; Lou, Kai; Zhu, Xiaorong R.; Mirkovic, Dragon; Poenisch, Falk; Grosshans, David

    2014-07-01

    We developed and investigated a positron emission tomography (PET) system for use with on-line (both in-beam and intra-fraction) image-guided adaptive proton therapy applications. The PET has dual rotating depth-of-interaction measurable detector panels by using solid-state photomultiplier (SSPM) arrays and LYSO scintillators. It has a 44 mm diameter trans-axial and 30 mm axial field-of-view (FOV). A 38 mm diameter polymethyl methacrylate phantom was placed inside the FOV. Both PET and phantom axes were aligned with a collimated 179.2 MeV beam. Each beam delivered ˜50 spills (0.5 s spill and 1.5 s inter-spill time, 3.8 Gy at Bragg peak). Data from each beam were acquired with detectors at a given angle. Nine datasets for nine beams with detectors at nine different angles over 180° were acquired for full-tomographic imaging. Each dataset included data both during and 5 min after irradiations. The positron activity-range was measured from the PET image reconstructed from all nine datasets and compared to the results from simulated images. A 22Na disc-source was also imaged after each beam to monitor the PET system's performance. PET performed well except for slight shifts of energy photo-peak positions (<1%) after each beam, due mainly to the neutron exposure of SSPM that increased the dark-count noise. This minor effect was corrected offline with a shifting 350-650 keV energy window for each dataset. The results show a fast converging of activity-ranges measured by the prototype PET with high sensitivity and uniform resolution. Sub-mm activity-ranges were achieved with minimal 6 s acquisition time and three spill irradiations. These results indicate the feasibility of PET for intra-fraction beam-range verification. Further studies are needed to develop and apply a novel clinical PET system for on-line image-guided adaptive proton therapy.

  13. Quality assurance of CT-PET alignment and image registration for radiation treatment planning

    International Nuclear Information System (INIS)

    Gong, S.J.; O'Keefe, G.J.; Gunawardana, D.H.

    2005-01-01

    A multi-layer point source phantom was first used to calibrate and verify the CT-PET system alignment. A partial whole-body Aldcrson RANDO Man Phantom (head through mid-femur) was externally and internally marked with small metal cannulas filled with 18F-FDG and then scanned with both modalities. Six series of phantom studies with different acquisition settings and scan positions were performed to reveal possible system bias and evaluate the accuracy and reliabilities of Philips Syntegra program in image alignment, coregistration and fusion. The registration error was assessed quantitatively by measuring the root-mean-square distance between the iso-centers of corresponding fiducial marker geometries in reference CT volumes and transformed CT or PET volumes. Results: Experimental data confirms the accuracy of manual, parameter, point and image-based registration using Syntegra is better than 2 mm. Comparisons between blind and cross definition of iso-centers of fiducial marks indicate that the fused CT and PET is superior to visual correlation of CT and PET side-by-side. Conclusion: In this work we demonstrate the QA procedures of Gemini image alignment and registration. Syntegra produces intrinsic and robust multi-modality image registration and fusion with careful user interaction. The registration accuracy is generally better than the spatial resolution of the PET scanner used and this appears to be sufficient for most RTP CT-PET registration procedures

  14. Filters in 2D and 3D Cardiac SPECT Image Processing

    Directory of Open Access Journals (Sweden)

    Maria Lyra

    2014-01-01

    Full Text Available Nuclear cardiac imaging is a noninvasive, sensitive method providing information on cardiac structure and physiology. Single photon emission tomography (SPECT evaluates myocardial perfusion, viability, and function and is widely used in clinical routine. The quality of the tomographic image is a key for accurate diagnosis. Image filtering, a mathematical processing, compensates for loss of detail in an image while reducing image noise, and it can improve the image resolution and limit the degradation of the image. SPECT images are then reconstructed, either by filter back projection (FBP analytical technique or iteratively, by algebraic methods. The aim of this study is to review filters in cardiac 2D, 3D, and 4D SPECT applications and how these affect the image quality mirroring the diagnostic accuracy of SPECT images. Several filters, including the Hanning, Butterworth, and Parzen filters, were evaluated in combination with the two reconstruction methods as well as with a specified MatLab program. Results showed that for both 3D and 4D cardiac SPECT the Butterworth filter, for different critical frequencies and orders, produced the best results. Between the two reconstruction methods, the iterative one might be more appropriate for cardiac SPECT, since it improves lesion detectability due to the significant improvement of image contrast.

  15. Current status and prospects of cardiac PET

    International Nuclear Information System (INIS)

    Yoshida, Katuya

    1999-01-01

    With positron emission tomography (PET), noninvasive measurements of myocardial blood flow and metabolism have now become possible. 1) Myocardial blood flow: We developed a high-resolution PET system for rabbits and showed that myocardial N-13 ammonnia uptake correlated well with flow measure with microspheres. We also demonstrated that a simplified PET protocol using N-13 ammonia or Rb-82 provide noninvasive measurement of coronary flow reserve in dog experiments. This protocol enables to produce estimates of myocardial blood flow in man and that are well correlated with the complex compartment model. 2) Myocardial glucose metabolism: We validated experimentally a simple method to quantify tissue glucose utilization with the brain reference index (BRI) using C-14 deoxyglucose and assessed its clinical feasibility for myocardial PET. 3) Membrane integrity: Loss of cell membrane integrity for trapping the potassium or it's analog is a market of myocardial necrosis/viability. We recently synthetized potassium-38 as a PET tracer and started an experimental study. (author)

  16. Predicting Response to Neoadjuvant Chemotherapy with PET Imaging Using Convolutional Neural Networks.

    Directory of Open Access Journals (Sweden)

    Petros-Pavlos Ypsilantis

    Full Text Available Imaging of cancer with 18F-fluorodeoxyglucose positron emission tomography (18F-FDG PET has become a standard component of diagnosis and staging in oncology, and is becoming more important as a quantitative monitor of individual response to therapy. In this article we investigate the challenging problem of predicting a patient's response to neoadjuvant chemotherapy from a single 18F-FDG PET scan taken prior to treatment. We take a "radiomics" approach whereby a large amount of quantitative features is automatically extracted from pretherapy PET images in order to build a comprehensive quantification of the tumor phenotype. While the dominant methodology relies on hand-crafted texture features, we explore the potential of automatically learning low- to high-level features directly from PET scans. We report on a study that compares the performance of two competing radiomics strategies: an approach based on state-of-the-art statistical classifiers using over 100 quantitative imaging descriptors, including texture features as well as standardized uptake values, and a convolutional neural network, 3S-CNN, trained directly from PET scans by taking sets of adjacent intra-tumor slices. Our experimental results, based on a sample of 107 patients with esophageal cancer, provide initial evidence that convolutional neural networks have the potential to extract PET imaging representations that are highly predictive of response to therapy. On this dataset, 3S-CNN achieves an average 80.7% sensitivity and 81.6% specificity in predicting non-responders, and outperforms other competing predictive models.

  17. Cardiac drugs used in cross-sectional cardiac imaging: what the radiologist needs to know

    International Nuclear Information System (INIS)

    McParland, P.; Nicol, E.D.; Harden, S.P.

    2010-01-01

    The demand for cross-sectional imaging of the heart is increasing dramatically and in many centres these imaging techniques are being performed by radiologists. Although radiologists are familiar with the computed tomography (CT) and magnetic resonance imaging (MRI) techniques to generate high-quality images and with using contrast agents, many are less familiar with administering the drugs necessary to perform CT coronary angiography and cardiac MR reliably. The aim of this article is to give an overview of the indications for and the contraindications to administering cardiac drugs in cross-sectional imaging departments. We also outline the complications that may be encountered and provide advice on how to treat these complications when they occur.

  18. Detection ability of FDG-PET/CT comparing with other imaging modalities in multiple myeloma patients

    International Nuclear Information System (INIS)

    Chae, Min Jeong; Lee, Tae Hyun; Pai, Moon Sun; Cheon, Gi Jeong; Choi, Chang Woon; Lim, Sang Moo

    2007-01-01

    Multiple myeloma (MM) is characterized by bone marrow infiltration with malignant plasma cells. It is important to detect involving bone for diagnosis and management of MM. The aim of this study was to evaluate the diagnostic ability and limitation of 18F-FDG-PET/CT (PET/CT) comparing other imaging modalities (separated PET and CT, whole body plain X-ray (XR), bone scintigraphy (BS), and MRI) in MM. Twenty PET/CT scans were performed in 16 patients (M: F=6: 10, median age=59 y). PET/CT findings were compared with available other images (n of CT=21, XR=21, BS=8, and MRI=5). Concordance with more than 2 image modalities, laboratory data, symptom, and biopsies were used for diagnosis of detected lesions. PET/CT revealed 256 of total 287 sites (sensitivity, 89.2%; accuracy, 84.8%). The sensitivity and accuracy of separating PET, CT, and XR were 86.3%, 70.4%; 47.4%, 50.3%; and 72.8%, 72.4%, respectively. Available BS identified 67 of 202 sites (sensitivity, 33.2%; accuracy, 44.0%). MRI detected 20 of 24 sites (sensitivity, 83.3%; accuracy, 36.3%). False positive rate (FP) of PET, XR, and MRI was as high as 87.8%, 95.1%, and 100%. PET for rib lesion identified 9 of 10 patients (90.0%) but for skull lesion only 4 of 7 patients (57.2%) with underestimation. 5 patients in MRI showed diffuse marrow signal change but only 3 had marrow involvement. But PET/CT showed higher accuracy than MRI. PET/CT was the most useful tool for detecting involving bone of MM comparing with other imaging modalities. Moreover, PET/CT is expected to overcome the limitations for the small osteolytic bone lesions with diffuse FDG uptake on PET

  19. Dual tracer functional imaging of gastroenteropancreatic neuroendocrine tumors using 68Ga-DOTA-NOC PET-CT and 18F-FDG PET-CT: competitive or complimentary?

    Science.gov (United States)

    Naswa, Niraj; Sharma, Punit; Gupta, Santosh Kumar; Karunanithi, Sellam; Reddy, Rama Mohan; Patnecha, Manish; Lata, Sneh; Kumar, Rakesh; Malhotra, Arun; Bal, Chandrasekhar

    2014-01-01

    This study aimed to compare the diagnostic performance of Ga-DOTANOC PET/CT with F-FDG PET/CT in the patients with gastroenteropancreatic neuroendocrine tumors (GEP-NETs). Data of 51 patients with definite histological diagnosis of GEP-NET who underwent both Ga-DOTA-NOC PET-CT and F-FDG PET-CT within a span of 15 days were selected for this retrospective analysis. Sensitivity, specificity, and predictive values were calculated for Ga-DOTA-NOC PET-CT and F-FDG PET-CT, and results were compared both on patientwise and regionwise analysis. Ga-DOTA-NOC PET-CT is superior to F-FDG PET-CT on patientwise analysis (P DOTA-NOC PET-CT is superior to F-FDG PET-CT only for lymph node metastases (P DOTA-NOC PET-CT detected more liver and skeletal lesions compared with F-FDG PET-CT, the difference was not statistically significant. In addition, the results of combined imaging helped in selecting candidates who would undergo the appropriate mode of treatment, whether octreotide therapy or conventional chemotherapy Ga-DOTA-NOC PET-CT seems to be superior to F-FDG PET-CT for imaging GEP-NETs. However, their role seems to be complementary because combination of Ga-DOTA-NOC PET-CT and F-FDG PET-CT in such patients helps demonstrate the total disease burden and segregate them to proper therapeutic groups.

  20. PET imaging of adoptive progenitor cell therapies

    International Nuclear Information System (INIS)

    Gelovani, Juri G.

    2008-01-01

    The overall objective of this application is to develop novel technologies for non-invasive imaging of adoptive stem cell-based therapies with positron emission tomography (PET) that would be applicable to human patients. To achieve this objective, stem cells will be genetically labeled with a PET-reporter gene and repetitively imaged to assess their distribution, migration, differentiation, and persistence using a radiolabeled reporter probe. This new imaging technology will be tested in adoptive progenitor cell-based therapy models in animals, including: delivery pro-apoptotic genes to tumors, and T-cell reconstitution for immunostimulatory therapy during allogeneic bone marrow progenitor cell transplantation. Technical and Scientific Merits. Non-invasive whole body imaging would significantly aid in the development and clinical implementation of various adoptive progenitor cell-based therapies by providing the means for non-invasive monitoring of the fate of injected progenitor cells over a long period of observation. The proposed imaging approaches could help to address several questions related to stem cell migration and homing, their long-term viability, and their subsequent differentiation. The ability to image these processes non-invasively in 3D and repetitively over a long period of time is very important and will help the development and clinical application of various strategies to control and direct stem cell migration and differentiation. Approach to accomplish the work. Stem cells will be genetically with a reporter gene which will allow for repetitive non-invasive 'tracking' of the migration and localization of genetically labeled stem cells and their progeny. This is a radically new approach that is being developed for future human applications and should allow for a long term (many years) repetitive imaging of the fate of tissues that develop from the transplanted stem cells. Why the approach is appropriate. The novel approach to stem cell imaging