WorldWideScience

Sample records for cardiac output

  1. Cardiac output during exercise

    DEFF Research Database (Denmark)

    Siebenmann, C; Rasmussen, P.; Sørensen, H.

    2015-01-01

    Several techniques assessing cardiac output (Q) during exercise are available. The extent to which the measurements obtained from each respective technique compares to one another, however, is unclear. We quantified Q simultaneously using four methods: the Fick method with blood obtained from...... the right atrium (Q(Fick-M)), Innocor (inert gas rebreathing; Q(Inn)), Physioflow (impedance cardiography; Q(Phys)), and Nexfin (pulse contour analysis; Q(Pulse)) in 12 male subjects during incremental cycling exercise to exhaustion in normoxia and hypoxia (FiO2  = 12%). While all four methods reported...... a progressive increase in Q with exercise intensity, the slopes of the Q/oxygen uptake (VO2) relationship differed by up to 50% between methods in both normoxia [4.9 ± 0.3, 3.9 ± 0.2, 6.0 ± 0.4, 4.8 ± 0.2 L/min per L/min (mean ± SE) for Q(Fick-M), Q(Inn), QP hys and Q(Pulse), respectively; P = 0...

  2. Cardiac output monitoring

    Directory of Open Access Journals (Sweden)

    Mathews Lailu

    2008-01-01

    Full Text Available Minimally invasive and non-invasive methods of estimation of cardiac output (CO were developed to overcome the limitations of invasive nature of pulmonary artery catheterization (PAC and direct Fick method used for the measurement of stroke volume (SV. The important minimally invasive techniques available are: oesophageal Doppler monitoring (ODM, the derivative Fick method (using partial carbon dioxide (CO 2 breathing, transpulmonary thermodilution, lithium indicator dilution, pulse contour and pulse power analysis. Impedance cardiography is probably the only non-invasive technique in true sense. It provides information about haemodynamic status without the risk, cost and skill associated with the other invasive or minimally invasive techniques. It is important to understand what is really being measured and what assumptions and calculations have been incorporated with respect to a monitoring device. Understanding the basic principles of the above techniques as well as their advantages and limitations may be useful. In addition, the clinical validation of new techniques is necessary to convince that these new tools provide reliable measurements. In this review the physics behind the working of ODM, partial CO 2 breathing, transpulmonary thermodilution and lithium dilution techniques are dealt with. The physical and the physiological aspects underlying the pulse contour and pulse power analyses, various pulse contour techniques, their development, advantages and limitations are also covered. The principle of thoracic bioimpedance along with computation of CO from changes in thoracic impedance is explained. The purpose of the review is to help us minimize the dogmatic nature of practice favouring one technique or the other.

  3. William Harvey, Peter Lauremberg and cardiac output.

    Science.gov (United States)

    Teichmann, G

    1992-11-01

    In 1636, the Rostock professor of medicine and the art of poetry, Peter Lauremberg (1585-1639), was one of the earliest to mention circulation which had been discovered by William Harvey and documented in his anatomical manual. In 1628 William Harvey proved the existence of the blood circulation by calculating the "cardiac output in a half an hour (semihora)". The answer to the question why Harvey chose half an hour as the time range can be found in the way of measuring time usual at that period. The sandglasses were turned half-hourly in maritime navigation and the wheel-clocks on shore had only the hour-hand. Improved chronometry was one of the prerequisites for measuring cardiac output. The minute-hand became usual after 1700 and the second-hand later on. Taking into consideration the alterations of cardiac output made the latter one of the most important circulation parameters in diagnostics, prognostication and therapeutics.

  4. Comparison of cardiac output measurement techniques

    DEFF Research Database (Denmark)

    Espersen, K; Jensen, E W; Rosenborg, D;

    1995-01-01

    Simultaneously measured cardiac output obtained by thermodilution (TD), transcutaneous suprasternal ultrasonic Doppler (DOP), CO2-rebreathing (CR) and the direct Fick method (FI) were compared in eleven healthy subjects in a supine position (SU), a sitting position (SI), and during sitting exercise...... at a workload of 50 W (EX). The agreements between the techniques, two by two, were expressed as the bias calculated as the averaged differences between the techniques. Precision was expressed as the standard deviation of the bias. The overall agreement (bias +/- precision) between TD, DOP and CR respectively...... and CR, respectively, and TD were 2.5 +/- 2.2 and 2.6 +/- 1.6 l/min. The overall agreement between DOP and CR was 0.1 +/- 1.6 l/min. In conclusion, TD overestimated cardiac output compared to the other techniques and the poor agreement has to be taken into consideration especially in measures of low...

  5. Methods and apparatus for determining cardiac output

    Science.gov (United States)

    Cohen, Richard J. (Inventor); Mukkamala, Ramakrishna (Inventor); Sherman, Derin A. (Inventor)

    2010-01-01

    The present invention provides methods and apparatus for determining a dynamical property of the systemic or pulmonary arterial tree using long time scale information, i.e., information obtained from measurements over time scales greater than a single cardiac cycle. In one aspect, the invention provides a method and apparatus for monitoring cardiac output (CO) from a single blood pressure signal measurement obtained at any site in the systemic or pulmonary arterial tree or from any related measurement including, for example, fingertip photoplethysmography.According to the method the time constant of the arterial tree, defined to be the product of the total peripheral resistance (TPR) and the nearly constant arterial compliance, is determined by analyzing the long time scale variations (greater than a single cardiac cycle) in any of these blood pressure signals. Then, according to Ohm's law, a value proportional to CO may be determined from the ratio of the blood pressure signal to the estimated time constant. The proportional CO values derived from this method may be calibrated to absolute CO, if desired, with a single, absolute measure of CO (e.g., thermodilution). The present invention may be applied to invasive radial arterial blood pressure or pulmonary arterial blood pressure signals which are routinely measured in intensive care units and surgical suites or to noninvasively measured peripheral arterial blood pressure signals or related noninvasively measured signals in order to facilitate the clinical monitoring of CO as well as TPR.

  6. Newer methods of cardiac output monitoring

    Institute of Scientific and Technical Information of China (English)

    Yatin; Mehta; Dheeraj; Arora

    2014-01-01

    Cardiac output(CO) is the volume of blood ejected by each ventricle per minute and is the product of stroke volume and heart rate. CO can thus be manipulated by alteration in heart rate or rhythm, preload, contractility and afterload. Moreover it gives important information about tissue perfusion and oxygen delivery. CO can be measured by various methods and thermodilution method using pulmonary artery catheter(PAC) is till date considered as gold standard method. Complications associated with PAC led to development of newer methods which are minimally or non-invasive. Newer methods fulfil other properties like continuous and reproducible reading, cost effective, reliable during various physiological states and have fast response time. These methods are validated against the gold standard with good level agreement. In this review we have discussed various newer methods of CO monitoring and their effectiveness in clinical use.

  7. Modelflow underestimates cardiac output in heat-stressed individuals

    DEFF Research Database (Denmark)

    Shibasaki, Manabu; Wilson, Thad E; Bundgaard-Nielsen, Morten

    2011-01-01

    An estimation of cardiac output can be obtained from arterial pressure waveforms using the Modelflow method. However, whether the assumptions associated with Modelflow calculations are accurate during whole body heating is unknown. This project tested the hypothesis that cardiac output obtained v...

  8. Peripheral vasodilatation determines cardiac output in exercising humans

    DEFF Research Database (Denmark)

    Bada, A A; Svendsen, J H; Secher, N H

    2012-01-01

    In dogs, manipulation of heart rate has no effect on the exercise-induced increase in cardiac output. Whether these findings apply to humans remain uncertain, because of the large differences in cardiovascular anatomy and regulation. To investigate the role of heart rate and peripheral...... arterial ATP infusion at rest. Exercise and ATP infusion increased cardiac output, leg blood flow and vascular conductance (P heart rate by up to 54 beats min(−1), cardiac output did not change in any of the three...... demonstrate that the elevated cardiac output during steady-state exercise is regulated by the increase in skeletal muscle blood flow and venous return to the heart, whereas the increase in heart rate appears to be secondary to the regulation of cardiac output....

  9. Validation of Fick cardiac output calculated with assumed oxygen consumption : a study of cardiac output during epoprostenol

    NARCIS (Netherlands)

    Bergstra, A; van den Heuvel, A F M; Zijlstra, F; Berger, R M F; Mook, G A; van Veldhuisen, D J

    2004-01-01

    OBJECTIVE: To test the validity of using assumed oxygen consumption for Fick cardiac output during administration of epoprostenol. METHODS: In 24 consecutive patients Fick cardiac output calculated with assumed oxygen consumption according to LaFarge and Miettinen (COLM) and according to Bergstra et

  10. Mini invasive hemodynamic monitoring: from arterial pressure to cardiac output

    OpenAIRE

    Della Rocca, Giorgio; Cecconi, Maurizio; Costa, Maria Gabriella

    2008-01-01

    To evaluate the Cardiac Output (CO) the standard invasive pulmonary artery catheter (PAC) is considered today the gold standard. The major criticism to the PAC is that its level of invasiveness is not supported by an improvement in patient's outcome. The interest to lesser and lesser invasive techniques is high. Therefore, the alternative techniques have been recently developed.Cardiac Output can be monitored continuously by different devices that analyze the arterial waveform to track change...

  11. Continuous measurement of cardiac output using stochastic system identification techniques.

    Science.gov (United States)

    Yelderman, Mark

    2004-01-01

    Indicator dilutions techniques offer the most reliable methods of determining clinical cardiac output because of the elastic nature of the cardiac vessels. A catheter-mounted beating filament affords a simple means of supplying "heat" indicator, but is power and temperature limited because of possible patient injury. A stochastic signal processing method using pseudorandom binary infusion of heat offers a process of enhancing the signal to noise sufficiently to facilitate a computation of cardiac output over a reasonable time period (5 min) with a clinically acceptable error.

  12. Predictors of low cardiac output in decompensated severe heart failure

    Directory of Open Access Journals (Sweden)

    Marcelo Eidi Ochiai

    2011-01-01

    Full Text Available OBJECTIVE: To identify predictors of low cardiac output and mortality in decompensated heart failure. INTRODUCTION: Introduction: Patients with decompensated heart failure have a high mortality rate, especially those patients with low cardiac output. However, this clinical presentation is uncommon, and its management is controversial. METHODS: We studied a cohort of 452 patients hospitalized with decompensated heart failure with an ejection fraction of 60 years, and 64.6% were men. Low cardiac output was present in 281 (63% patients on admission. Chagas disease was the cause of heart failure in 92 (20.4% patients who had higher B type natriuretic peptide levels (1,978.38 vs. 1,697.64 pg/mL; P = 0.015. Predictors of low cardiac output were Chagas disease (RR: 3.655, P<0.001, lower ejection fraction (RR: 2.414, P<0.001, hyponatremia (RR: 1.618, P = 0.036, and renal dysfunction (RR: 1.916, P = 0.007. Elderly patients were inversely associated with low cardiac output (RR: 0.436, P = 0.001. Predictors of mortality were Chagas disease (RR: 2.286, P<0.001, ischemic etiology (RR: 1.449, P = 0.035, and low cardiac output (RR: 1.419, P = 0.047. CONCLUSIONS: In severe decompensated heart failure, predictors of low cardiac output are Chagas disease, lower ejection fraction, hyponatremia, and renal dysfunction. Additionally, Chagas disease patients have higher B type natriuretic peptide levels and a worse prognosis independent of lower ejection fraction.

  13. Volume and its relationship to cardiac output and venous return.

    Science.gov (United States)

    Magder, S

    2016-09-10

    Volume infusions are one of the commonest clinical interventions in critically ill patients yet the relationship of volume to cardiac output is not well understood. Blood volume has a stressed and unstressed component but only the stressed component determines flow. It is usually about 30 % of total volume. Stressed volume is relatively constant under steady state conditions. It creates an elastic recoil pressure that is an important factor in the generation of blood flow. The heart creates circulatory flow by lowering the right atrial pressure and allowing the recoil pressure in veins and venules to drain blood back to the heart. The heart then puts the volume back into the systemic circulation so that stroke return equals stroke volume. The heart cannot pump out more volume than comes back. Changes in cardiac output without changes in stressed volume occur because of changes in arterial and venous resistances which redistribute blood volume and change pressure gradients throughout the vasculature. Stressed volume also can be increased by decreasing vascular capacitance, which means recruiting unstressed volume into stressed volume. This is the equivalent of an auto-transfusion. It is worth noting that during exercise in normal young males, cardiac output can increase five-fold with only small changes in stressed blood volume. The mechanical characteristics of the cardiac chambers and the circulation thus ultimately determine the relationship between volume and cardiac output and are the subject of this review.

  14. Pulse contour-derived cardiac output in hemodialysis patients

    DEFF Research Database (Denmark)

    Cordtz, Joakim; Ladefoged, Soeren D

    2010-01-01

    analysis, namely the Finometer monitor (FNM) for further use on patients dialyzing on a central vascular catheter. Fifty simultaneous cardiac output measurements were obtained during hemodialysis sessions in 25 patients. The internal variability of the FNM measurements was assessed by comparing 24 pairs...

  15. Pulse contour-derived cardiac output in hemodialysis patients

    DEFF Research Database (Denmark)

    Cordtz, Joakim; Ladefoged, Soeren D

    2010-01-01

    Reliable methods for cardiac output determination are essential for studying the pathophysiology of intradialytic hypotension. Use of the current gold standard, the Transonic monitor, requires an arteriovenous fistula. We wished to verify the accuracy of a method based on finger pulse contour...

  16. Evaluation of noninvasive cardiac output methods during exercise

    Science.gov (United States)

    Moore, Alan D.; Barrows, Linda H.; Rashid, Michael; Siconolfi, Steven F.

    1992-01-01

    Noninvasive techniques to estimate cardiac output (Qc) will be used during future space flight. This retrospective literature survey compared the Qc techniques of carbon dioxide rebreathing (CO2-R), CO2 single breath (CO2-S), Doppler (DOP), impedance (IM), and inert gas (IG: acetylene or nitrous oxide) to direct (DIR) assessments measured at rest and during exercise.

  17. Invasive and non-invasive methods for cardiac output measurement

    Directory of Open Access Journals (Sweden)

    Lavdaniti M.

    2008-01-01

    Full Text Available The hemodynamic status monitoring of high-risk surgical patients and critically ill patients inIntensive Care Units is one of the main objectives of their therapeutic management. Cardiac output is one of the mostimportant parameters for cardiac function monitoring, providing an estimate of whole body perfusion oxygen deliveryand allowing for an understanding of the causes of high blood pressure. The purpose of the present review is thedescription of cardiac output measurement methods as presented in the international literature. The articles documentthat there are many methods of monitoring the hemodynamic status of patients, both invasive and non-invasive, themost popular of which is thermodilution. The invasive methods are the Fick method and thermodilution, whereasthe non-invasive methods are oeshophaegeal Doppler, transoesophageal echocardiography, lithium dilution, pulsecontour, partial CO2 rebreathing and thoracic electrical bioimpedance. All of them have their advantages and disadvantages,but thermodilution is the golden standard for critical patients, although it does entail many risks. The idealsystem for cardiac output monitoring would be non-invasive, easy to use, reliable and compatible in patients. A numberof research studies have been carried out in clinical care settings, by nurses as well as other health professionals, for thepurpose of finding a method of measurement that would have the least disadvantages. Nevertheless, the thermodilutiontechnique remains the most common approach in use today.

  18. Measurement of cardiac output from dynamic pulmonary circulation time CT

    Energy Technology Data Exchange (ETDEWEB)

    Yee, Seonghwan, E-mail: Seonghwan.Yee@Beaumont.edu [Department of Radiation Oncology, Beaumont Health System, Royal Oak, Michigan 48073 (United States); Scalzetti, Ernest M. [Department of Radiology, SUNY Upstate Medical University, Syracuse, New York 13210 (United States)

    2014-06-15

    Purpose: To introduce a method of estimating cardiac output from the dynamic pulmonary circulation time CT that is primarily used to determine the optimal time window of CT pulmonary angiography (CTPA). Methods: Dynamic pulmonary circulation time CT series, acquired for eight patients, were retrospectively analyzed. The dynamic CT series was acquired, prior to the main CTPA, in cine mode (1 frame/s) for a single slice at the level of the main pulmonary artery covering the cross sections of ascending aorta (AA) and descending aorta (DA) during the infusion of iodinated contrast. The time series of contrast changes obtained for DA, which is the downstream of AA, was assumed to be related to the time series for AA by the convolution with a delay function. The delay time constant in the delay function, representing the average time interval between the cross sections of AA and DA, was determined by least square error fitting between the convoluted AA time series and the DA time series. The cardiac output was then calculated by dividing the volume of the aortic arch between the cross sections of AA and DA (estimated from the single slice CT image) by the average time interval, and multiplying the result by a correction factor. Results: The mean cardiac output value for the six patients was 5.11 (l/min) (with a standard deviation of 1.57 l/min), which is in good agreement with the literature value; the data for the other two patients were too noisy for processing. Conclusions: The dynamic single-slice pulmonary circulation time CT series also can be used to estimate cardiac output.

  19. Validation of transpulmonary thermodilution cardiac output measurement in a pediatric animal model.

    NARCIS (Netherlands)

    Lemson, J.; Boode, W.P. de; Hopman, J.C.W.; Singh, S.K.; Hoeven, J.G. van der

    2008-01-01

    OBJECTIVE: This study was undertaken to validate the transpulmonary thermodilution cardiac output measurement (CO(TPTD)) in a controlled newborn animal model under various hemodynamic conditions with special emphasis on low cardiac output. DESIGN: Prospective, experimental, pediatric animal study. S

  20. Cardiac output and vasodilation in the vasovagal response

    DEFF Research Database (Denmark)

    Wieling, Wouter; Jardine, David L; de Lange, Frederik J

    2016-01-01

    with vagal-induced bradycardia in simple faint. Studies performed by Barcroft and Sharpey-Schafer between 1940 and 1950 used volume-based plethysmography to demonstrate major forearm vasodilation during extreme hypotension and concluded that the main mechanism for hypotension was vasodilation...... of CO using the Fick principle. They demonstrated that CO significantly fell before syncope, and little vasodilation occurred until very late in the vasovagal reaction Thus, since the 1970s, decreasing cardiac output rather than vasodilation has been regarded as the principal mechanism...

  1. A computerised dichromatic earpiece densitometer for the measurement of cardiac output.

    Science.gov (United States)

    Robinson, P S; Crowther, A; Jenkins, B S; Webb-Peploe, M M; Coltart, D J

    1979-07-01

    This study assesses a precalibrated dichromatic earpiece densitometer and microprocessor for the measurement of cardiac output by indocyanine green dye dilution. The measured cardiac output is compared with values of cardiac output simultaneously determined using a cuvette densitometer. The microprocessor computation of cardiac output agreed very closely with the cardiac output determined by manual calculation from the same dye dilution curves (standard deviation +/- 1.47%). The reproducibility of the earpiece densitometer (standard deviation +/- 5.2%) was virtually identical to that of the cuvette densitometer (+/- 5.3%). In a comparison of earpiece and cuvette densitometers for 60 measurements of cardiac output following pulmonary arterial injection of dye and for 50 measurements following femoral venous injection of dye, correlation coefficients were 0.83 and 0.78 and the standard deviations of the differences of simultaneous measurements were 7.2% and 8.3% respectively. The instrument offers an accurate reproducible and relatively noninvasive technique for measuring cardiac output.

  2. The decrease of cardiac chamber volumes and output during positive-pressure ventilation

    DEFF Research Database (Denmark)

    Kristensen, Kasper Kyhl; Ahtarovski, Kiril Aleksov; Iversen, Kasper

    2013-01-01

    the effect of PPV on the central circulation by studying cardiac chamber volumes with cardiac magnetic resonance imaging (CMR). We hypothesized that PPV lowers cardiac output (CO) mainly via the Frank-Starling relationship. In 18 healthy volunteers, cardiac chamber volumes and flow in aorta and the pulmonary...

  3. Cardiac output estimation using pulmonary mechanics in mechanically ventilated patients

    Directory of Open Access Journals (Sweden)

    Hann Christopher E

    2010-11-01

    Full Text Available Abstract The application of positive end expiratory pressure (PEEP in mechanically ventilated (MV patients with acute respiratory distress syndrome (ARDS decreases cardiac output (CO. Accurate measurement of CO is highly invasive and is not ideal for all MV critically ill patients. However, the link between the PEEP used in MV, and CO provides an opportunity to assess CO via MV therapy and other existing measurements, creating a CO measure without further invasiveness. This paper examines combining models of diffusion resistance and lung mechanics, to help predict CO changes due to PEEP. The CO estimator uses an initial measurement of pulmonary shunt, and estimations of shunt changes due to PEEP to predict CO at different levels of PEEP. Inputs to the cardiac model are the PV loops from the ventilator, as well as the oxygen saturation values using known respiratory inspired oxygen content. The outputs are estimates of pulmonary shunt and CO changes due to changes in applied PEEP. Data from two published studies are used to assess and initially validate this model. The model shows the effect on oxygenation due to decreased CO and decreased shunt, resulting from increased PEEP. It concludes that there is a trade off on oxygenation parameters. More clinically importantly, the model also examines how the rate of CO drop with increased PEEP can be used as a method to determine optimal PEEP, which may be used to optimise MV therapy with respect to the gas exchange achieved, as well as accounting for the impact on the cardiovascular system and its management.

  4. ASSUMED OXYGEN-CONSUMPTION BASED ON CALCULATION FROM DYE DILUTION CARDIAC-OUTPUT - AN IMPROVED FORMULA

    NARCIS (Netherlands)

    BERGSTRA, A; VANDIJK, RB; HILLEGE, HL; LIE, KI; MOOK, GA

    1995-01-01

    This study was performed because of observed differences between dye dilution cardiac output and the Fick cardiac output, calculated from estimated oxygen consumption according to LaFarge and Miettinen, and to find a better formula for assumed oxygen consumption. In 250 patients who underwent left a

  5. Non-invasive cardiac output monitoring in neonates using bioreactance: a comparison with echocardiography.

    LENUS (Irish Health Repository)

    Weisz, Dany E

    2012-01-01

    Non-invasive cardiac output monitoring is a potentially useful clinical tool in the neonatal setting. Our aim was to evaluate a new method of non-invasive continuous cardiac output (CO) measurement (NICOM™) based on the principle of bioreactance in neonates.

  6. Kredsløbsmonitorering af kritisk syge patienter med "pulse contour cardiac output"-systemet

    DEFF Research Database (Denmark)

    Afshari, Arash; Perner, Anders; Bonde, Jan

    2006-01-01

    The Pulse Contour Cardiac Output (PiCCO) monitoring system measures cardiac output with high precision and accuracy. The system may replace the pulmonary artery catheter in most critically ill patients because the rate of serious complications may be lower. Whether the use of dynamic or static...

  7. Kredsløbsmonitorering med lithium dilution cardiac output-systemet

    DEFF Research Database (Denmark)

    Christiansen, Christian; Hostrup, Anette; Tønnesen, Else

    2008-01-01

    The lithium dilution cardiac output (LiDCO) system measures cardiac output beat-to-beat with high precision. The system is based on an arterial pulse power analysis which is calibrated every eight hours with a small non-pharmacological dose of lithium. The system is minimally invasive; it requires...

  8. Lack of agreement and trending ability of the endotracheal cardiac output monitor compared with thermodilution

    DEFF Research Database (Denmark)

    Møller-Sørensen, H; Hansen, K L; Ostergaard, M

    2012-01-01

    cardiac output (CO) during steady state and with induced haemodynamic changes in patients scheduled for elective cardiac surgery. METHODS: Twenty-five patients were enrolled. After induction of anaesthesia, endotracheal intubation using a dedicated ECOM tube, and insertion of the pulmonary artery catheter......BACKGROUND: Minimally invasive monitoring systems of central haemodynamics are gaining increasing popularity. The present study investigated the precision of the endotracheal cardiac output monitor (ECOM) system and its agreement with pulmonary artery catheter thermodilution (PAC TD) for measuring...

  9. Measurement of cardiac output in adult and newborn animals by ascorbic acid dilution.

    Science.gov (United States)

    Smallwood, J K; Haselby, K A; Paradise, R R

    1984-05-01

    We have developed an ascorbic acid-dilution method for measuring cardiac output which requires minimal blood withdrawal. Ascorbate is injected into a central venous catheter. The indicator-dilution curve is obtained by drawing blood from an arterial catheter through an amperometric cell at 0.96 ml/min for 35 s. The current is measured by a picoammeter . A calibration curve is obtained in 15 s prior to each indicator-dilution curve. An on-line digital computer measures the curve areas and calculates the cardiac output. Cardiac outputs of heparinized dogs anesthetized with pentobarbital and halothane measured by this method (AA) compared closely to cardiac outputs measured by the dye-dilution method (CG) (AA = 0.96 CG + 20 ml/min, r = 0.98). Both the cardiac output and the arterial blood pressure remained stable during replicate measurements of the cardiac output of 1-day-old piglets. This system allows cardiac output determinations of neonatal subjects without excessive blood removal and, with further development, should be practical in human neonates.

  10. Reproducibility of cardiac power output and other cardiopulmonary exercise indices in patients with chronic heart failure.

    Science.gov (United States)

    Jakovljevic, Djordje G; Seferovic, Petar M; Nunan, David; Donovan, Gay; Trenell, Michael I; Grocott-Mason, Richard; Brodie, David A

    2012-02-01

    Cardiac power output is a direct measure of overall cardiac function that integrates both flow- and pressure-generating capacities of the heart. The present study assessed the reproducibility of cardiac power output and other more commonly reported cardiopulmonary exercise variables in patients with chronic heart failure. Metabolic, ventilatory and non-invasive (inert gas re-breathing) central haemodynamic measurements were undertaken at rest and near-maximal exercise of the modified Bruce protocol in 19 patients with stable chronic heart failure. The same procedure was repeated 7 days later to assess reproducibility. Cardiac power output was calculated as the product of cardiac output and mean arterial pressure. Resting central haemodynamic variables demonstrate low CV (coefficient of variation) (ranging from 3.4% for cardiac output and 5.6% for heart rate). The CV for resting metabolic and ventilatory measurements ranged from 8.2% for respiratory exchange ratio and 14.2% for absolute values of oxygen consumption. The CV of anaerobic threshold, peak oxygen consumption, carbon dioxide production and respiratory exchange ratio ranged from 3.8% (for anaerobic threshold) to 6.4% (for relative peak oxygen consumption), with minute ventilation having a CV of 11.1%. Near-maximal exercise cardiac power output and cardiac output had CVs of 4.1 and 2.2%, respectively. Cardiac power output demonstrates good reproducibility suggesting that there is no need for performing more than one cardiopulmonary exercise test. As a direct measure of cardiac function (dysfunction) and an excellent prognostic marker, it is strongly advised in the assessment of patients with chronic heart failure undergoing cardiopulmonary exercise testing.

  11. Cardiac output measurement : evaluation of methods in ICU patients

    NARCIS (Netherlands)

    Wilde, Robert Bernard Pieter de

    2009-01-01

    Accurate clinical assessment of the circulatory status is particular desirable in critically ill patients in the intensive care unit (ICU) and patients undergoing cardiac, thoracic, or vascular interventions. As the patient’s haemodynamic status may change rapidly, continuous monitoring of cardiac o

  12. Improvements in determination of cardiac output with a Swan-Ganz catheter.

    Science.gov (United States)

    Sakagami, M; Kuwana, K; Nakanishi, H; Sakai, K

    1990-01-01

    The time constant for heat transfer may affect exact determination of cardiac output with Swan-Ganz catheters. Commercially available Swan-Ganz catheters are provided with thermistors with varying time constants. Current monitoring of cardiac output is not corrected for these time constants, so the conventional method of determining cardiac output using the equation of Stewart-Hamilton produces marked errors. The authors propose a new method of determining cardiac output with Swan-Ganz catheters with varying time constants from thermal dilution curve data based on Newton's cooling law. Values for blood flow rate determined by the new method using a completely stirred tank of original design, mimicking the natural heart and using bovine blood, are almost the same as values observed at varying saline infusion volumes, saline temperatures, and saline infusion times.

  13. Comparison of cardiac output determined by bioimpedance and bioreactance methods at rest and during exercise.

    Science.gov (United States)

    Jakovljevic, Djordje G; Moore, Sarah; Hallsworth, Kate; Fattakhova, Gulnar; Thoma, Christian; Trenell, Michael I

    2012-04-01

    Bioreactance is a novel non-invasive method for cardiac output measurement that involves the analysis of blood flow-dependent changes in the phase shifts of electrical currents applied across the chest. The present study (1) compared resting and exercise cardiac outputs determined by bioreactance and bioimpedance methods and those estimated from measured oxygen consumption, (2) determined the relationship between cardiac output and oxygen consumption, and (3) assessed the agreement between the bioreactance and bioimpedance methods. Twelve healthy subjects (aged 30 ± 4 years) performed graded cardiopulmonary exercise test on a recumbent cycle ergometer on two occasions, 1 week apart. Cardiac output was monitored at rest, at 30, 50, 70, 90, 150 W and at peak exercise intensity by bioreactance and bioimpedance and expired gases collected. Resting cardiac output was not significantly different between the bioreactance and bioimpedance methods (6.2 ± 1.4 vs. 6.5 ± 1.4 l min(-1), P = 0.42). During exercise cardiac outputs were correlated with oxygen uptake for both bioreactance (r = 0.84, P bioimpedance techniques (r = 0.82, P bioimpedance estimated significantly lower cardiac outputs than both bioreactance and theoretically calculated cardiac output (14.3 ± 2.6 vs. 17.5 ± 5.2 vs. 16.9 ± 4.9 l min(-1), P bioimpedance method reported ~1.5 l min(-1) lower cardiac output than bioreactance with lower and upper limits of agreement of -2.98 to 5.98 l min(-1). Bioimpedance and bioreactance methods provide different cardiac output estimates, particularly at high exercise intensity, and therefore the two methods cannot be used interchangeably. In contrast with bioimpedance, bioreactance cardiac outputs are similar to those estimated from measured oxygen consumption.

  14. Evaluation of transpulmonary thermodilution as a method to measure cardiac output in anesthetized cats.

    Science.gov (United States)

    Beaulieu, Kim E; Kerr, Carolyn L; McDonell, Wayne N

    2009-01-01

    The objectives of this study were to evaluate the use of a transpulmonary thermodilution (Trans) technique for the measurement of cardiac output, and to determine the agreement between Trans and conventional thermodilution (TD) in anesthetized cats. Using each technique, cardiac output was measured in 5 mature cats (weights 2.4 to 5.6 kg) anesthetized with isoflurane. To induce different levels of cardiac output in each cat, anesthesia was maintained at > 1.5x end-tidal minimum alveolar concentration (MAC) of isoflurane, and at 1.3x end-tidal isoflurane MAC with and without administration of dobutamine. At least 2 comparisons between TD and Trans values were made at each cardiac output rate. Thirty-two of the 42 recorded comparisons were analyzed. Linear regression analysis (TD vs Trans) yielded an r(2) value of 0.83. The mean bias (TD-Trans) was -3.7 mL/kg/min with limits of agreement of -35.9 to 28.5 mL/kg/min. The concordance coefficient was 0.91. The Trans method showed good relationship and good agreement with TD in anesthetized cats. The Trans method is a relatively noninvasive, practical, and safe method to measure cardiac output in anesthetized cats.

  15. Impedance cardiography for estimating cardiac output during submaximal and maximal work.

    Science.gov (United States)

    Kobayashi, Y; Andoh, Y; Fujinami, T; Nakayama, K; Takada, K; Takeuchi, T; Okamoto, M

    1978-09-01

    Impedance cardiography was used to estimate cardiac output in 10 men during rest and within 5 s after exercise on a bicycle ergometer, including work up to and including maximal aerobic capacity. An indwelling venous catheter permitted simultaneous sampling of venous blood for observing changes in hematocrit associated with each exercise level. Cardiac output, calculated from a standard equation which assumes a constant value of 150 omega.cm for the electrical resistivity of blood, was compared with corresponding calculations in which blood resistivity was individually determined as a function of hematocrit. It is concluded that many of the discrepancies in the literature related to values for cardiac output obtained during exercise by the impedance method may be inherent in calculations that do not consider the changing electrical resistivity of the blood with a changing hematocrit.

  16. Pacing to treat low cardiac output syndrome following elective aortic valve replacement

    Directory of Open Access Journals (Sweden)

    Muhammad Ishaq

    2012-01-01

    Full Text Available We report a case of low cardiac output syndrome caused by dynamic left ventricular (LV outflow obstruction after aortic valve replacement (AVR. This recognized phenomenon probably occurs more frequently than appreciated, and the author suggests that this should be considered when managing patients with severe hemodynamic instability after AVR. In addition, we also focus on the fact that invasive pacemaker systems have significant effects on cardiac output augmentation postoperatively and in long-term management of patients with LV outflow tract (LVOT obstruction following AVR. The possible mechanisms and subsequent treatments are discussed.

  17. Comparison of an advanced minimally invasive cardiac output monitoring with a continuous invasive cardiac output monitoring during lung transplantation.

    Science.gov (United States)

    Tomasi, Roland; Prueckner, Stephan; Czerner, Stephan; Schramm, Renè; Preissler, Gerhard; Zwißler, Bernhard; von Dossow-Hanfstingl, Vera

    2016-08-01

    The aim of this study was to compare a continuous non-calibrated left heart cardiac index (CI) measurement by arterial waveform analysis (FloTrac(®)/Vigileo(®)) with a continuous calibrated right heart CI measurement by pulmonary artery thermodilution (CCOmbo-PAC(®)/Vigilance II(®)) for hemodynamic monitoring during lung transplantation. CI was measured simultaneously by both techniques in 13 consecutive lung transplants (n = 4 single-lung transplants, n = 9 sequential double-lung transplants) at distinct time points perioperatively. Linear regression analysis and Bland-Altman analysis with percentage error calculation were used for statistical comparison of CI measurements by both techniques. In this study the FloTrac(®) system underestimated the CI in comparison with the continuous pulmonary arterial thermodilution (p waveform and continuous pulmonary artery thermodilution are, therefore, not interchangeable during these complex operations.

  18. A model to calculate cardiac output in hemodialysis patients by thermodilution

    Directory of Open Access Journals (Sweden)

    Alayoud Ahmed

    2012-06-01

    Full Text Available Abstract The Blood Temperature Monitor module (BTM is used to measure recirculation by thermodilution in dialysis. Numerous studies have confirmed its interest in the measuring of the vascular access flow. In this letter we describe a model to calculate cardiac output in dialysis by the BTM.

  19. Assessment of cardiac output with transpulmonary thermodilution during exercise in humans

    DEFF Research Database (Denmark)

    Calbet, José A L; Boushel, Robert

    2015-01-01

    The accuracy and reproducibility of transpulmonary thermodilution (TPTd) to assess cardiac output (Q̇) in exercising men was determined using indocyanine green (ICG) dilution as a reference method. TPTd has been utilized for the assessment of Q̇ and preload indexes of global end-diastolic volume...

  20. Effect of Hemorrhage on Cardiac Output, PVP, Alodosterone and Diuresis during Immersion in Men

    Science.gov (United States)

    Simanonok, K.; Greenleaf, John E.; Bernauer, E. M.; Wade, C. E.; Keil, L. C.

    1990-01-01

    The purpose of this study was to test the hypothesis that a reduction in blood volume would attenuate or eliminate immersion-induced increases in cardiac output (Q (sup dot) sub co)) and urine excretion, and to investigate accompanying vasoactive and fluid-electrolyte hormonal responses.

  1. IMPROVING AGREEMENT BETWEEN THORACIC BIOIMPEDANCE AND DYE DILUTION CARDIAC-OUTPUT ESTIMATION IN CHILDREN

    NARCIS (Netherlands)

    OCONNELL, AJ; TIBBALLS, J; COULTHARD, M

    1991-01-01

    The measurement of thoracic electrical bioimpedance (TEB) offers a continuous, non-invasive method for monitoring cardiac output (CO). For clinical use, agreement with a current standard should be demonstrated. We describe a modification to the manufacturer's suggested data entry into the NCCOM3-R6

  2. Phlebotomy eliminates the maximal cardiac output response to six weeks of exercise training

    DEFF Research Database (Denmark)

    Bonne, Thomas Christian; Doucende, Gregory; Flück, Daniela

    2014-01-01

    With this study we tested the hypothesis that six weeks of endurance training increases maximal cardiac output (Qmax) relatively more by elevating blood volume (BV) than by inducing structural and functional changes within the heart. Nine healthy but untrained volunteers (VO2max 47 ± 5 ml.min(-1)...

  3. Cardiac output measurement by bioimpedance and noninvasive pulse contour analysis compared with the continuous pulmonary artery thermodilution technique

    NARCIS (Netherlands)

    Maass, Saskia W. M. C.; Roekaerts, Paul M. H. J.; Lance, Marcus D.

    2014-01-01

    Objective: The aim of the present study was to compare 2 noninvasive cardiac output measurement methods with the continuous cardiac output thermodilution (CCO-TD) method. Design: A single-center prospective design. Setting: A university hospital. Participants: Fifty-three consecutive patients schedu

  4. Peripartum cardiomyopathy: postpartum decompensation and use of non-invasive cardiac output monitoring.

    Science.gov (United States)

    Lorello, G; Cubillos, J; McDonald, M; Balki, M

    2014-02-01

    The utility of a non-invasive cardiac output monitor (NICOM™) in guiding the peripartum management and identification of postpartum complications in a patient with severe peripartum cardiomyopathy is reported. A 31-year-old nulliparous woman at 35 weeks of gestation presented with a three-week history of worsening dyspnea and progressive functional deterioration. A transthoracic echocardiogram showed severe left ventricular systolic dysfunction with an ejection fraction peripartum cardiomyopathy. We suggest that use of NICOM™ be extended into the postpartum period to detect signs of cardiac decompensation in such patients.

  5. Continuous measurement of cardiac output with the use of stochastic system identification techniques.

    Science.gov (United States)

    Yelderman, M

    1990-10-01

    The limitations of developing a technique to measure cardiac output continuously are given. Logical explanations are provided for the economic, technical, and physiologic benefits of a stochastic system identification technique for measuring cardiac output. Heat is supplied by a catheter-mounted filament driven according to a pseudorandom binary sequence. Volumetric fluid flow is derived by a cross-correlation algorithm written in the C language. In vitro validation is performed with water in a flow bench. The computed flow (y) compared with the in-line-measured flow (x) yields the linear regression y = 1.024x - 0.157 (r = 0.99). The average coefficient of variation is less than 2% over a volumetric fluid flow range of 2 to 10 L/min.

  6. Estimating changes in cardiac output using an implanted hemodynamic monitor in heart failure patients

    DEFF Research Database (Denmark)

    Ståhlberg, Marcus; Damgaard, Morten; Ersgård, David;

    2010-01-01

    OBJECTIVES: The aim of this study was to evaluate an algorithm that estimates changes in cardiac output (CO) from right ventricular (RV) pressure waveforms derived from an implantable hemodynamic monitor (IHM) in heart failure patients. DESIGN: Twelve heart failure patients (NYHA II-III, EF 32......%) with an implantable hemodynamic monitor (Chronicle) were included in this study. Changes in cardiac output were provoked by body position change at rest (left lateral supine, horizontal supine, sitting, and standing) and a steady state bicycle exercise at 20 watts. Estimated CO derived from the IHM (CO...... was -0.39 L/min (11%). Limits of agreement were +/-1.56 L/min and relative error was 21%. CONCLUSIONS: A simple algorithm based on RV pressure wave form characteristics derived from an IHM can be used to estimate changes in CO in heart failure patients. These findings encourage further research aiming...

  7. Levosimendan in a neonate with severe coarctation of aorta and low cardiac output syndrome

    Directory of Open Access Journals (Sweden)

    Yann Olivier Boegli

    2013-01-01

    Full Text Available We report successful use of levosimendan after failed balloon angioplasty in a critically ill neonate with coarctation of aorta (CoA and severe low cardiac output syndrome (LCOS. Treatment with levosimendan improved left heart function, and decreased lactate and brain natriuretic peptide levels. To our knowledge, this is the first report on the safe and successful use of levosimendan in the management of LCOS due to severe CoA in a neonate awaiting surgical repair.

  8. The effects of long-term aerobic exercise on cardiac structure, stroke volume of the left ventricle, and cardiac output.

    Science.gov (United States)

    Lee, Bo-Ae; Oh, Deuk-Ja

    2016-02-01

    The purpose of this study is to investigate the effect of the long-term aerobic exercises on cardiac structure, left ventricular stroke volume, and cardiac output. To achieve the purpose of the study, a total of 22 volunteers-including 10 people who have continued regular exercises and 12 people as the control group-were selected as subjects. With regard to data processing, the IBM SPSS Statistics ver. 21.0 was used to calculate the mean and standard deviation, and the difference of the means between the groups was verified through an independent t-test. As a result, there were significant differences between groups in the left ventricular end-diastolic internal dimension, left ventricular end-systolic internal dimension, left ventricular end-diastolic septum thickness. There were significant differences between groups in left ventricular end-diastolic volume, left ventricular mass, and left ventricular mass index per body surface area. However, in cardiac function, only left ventricular stroke volume showed a significant difference between groups.

  9. Multisite Tissue Oxygenation Monitoring Indicates Organ-Specific Flow Distribution and Oxygen Delivery Related to Low Cardiac Output in Preterm Infants With Clinical Sepsis

    NARCIS (Netherlands)

    van der Laan, Michelle E.; Roofthooft, Marcus T. R.; Fries, Marian W. A.; Schat, Trijntje E.; Bos, Arend F.; Berger, Rolf M. F.; Kooi, Elisabeth M. W.

    2016-01-01

    Objectives: Cardiac output may be compromised in preterm infants with sepsis. Whether low cardiac output is associated with low tissue oxygen supply in these patients is unclear. The aim of the current study was to assess the association between cardiac output, assessed by echocardiography, and tiss

  10. High flow variant postural orthostatic tachycardia syndrome amplifies the cardiac output response to exercise in adolescents.

    Science.gov (United States)

    Pianosi, Paolo T; Goodloe, Adele H; Soma, David; Parker, Ken O; Brands, Chad K; Fischer, Philip R

    2014-08-01

    Postural orthostatic tachycardia syndrome (POTS) is characterized by chronic fatigue and dizziness and affected individuals by definition have orthostatic intolerance and tachycardia. There is considerable overlap of symptoms in patients with POTS and chronic fatigue syndrome (CFS), prompting speculation that POTS is akin to a deconditioned state. We previously showed that adolescents with postural orthostatic tachycardia syndrome (POTS) have excessive heart rate (HR) during, and slower HR recovery after, exercise - hallmarks of deconditioning. We also noted exaggerated cardiac output during exercise which led us to hypothesize that tachycardia could be a manifestation of a high output state rather than a consequence of deconditioning. We audited records of adolescents presenting with long-standing history of any mix of fatigue, dizziness, nausea, who underwent both head-up tilt table test and maximal exercise testing with measurement of cardiac output at rest plus 2-3 levels of exercise, and determined the cardiac output () versus oxygen uptake () relationship. Subjects with chronic fatigue were diagnosed with POTS if their HR rose ≥40 beat·min(-1) with head-up tilt. Among 107 POTS patients the distribution of slopes for the , relationship was skewed toward higher slopes but showed two peaks with a split at ~7.0 L·min(-1) per L·min(-1), designated as normal (5.08 ± 1.17, N = 66) and hyperkinetic (8.99 ± 1.31, N = 41) subgroups. In contrast, cardiac output rose appropriately with in 141 patients with chronic fatigue but without POTS, exhibiting a normal distribution and an average slope of 6.10 ± 2.09 L·min(-1) per L·min(-1). Mean arterial blood pressure and pulse pressure from rest to exercise rose similarly in both groups. We conclude that 40% of POTS adolescents demonstrate a hyperkinetic circulation during exercise. We attribute this to failure of normal regional vasoconstriction during exercise, such that patients must increase flow through an

  11. Non-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing technique

    DEFF Research Database (Denmark)

    Gabrielsen, Anders; Videbaek, Regitze; Schou, Morten

    2002-01-01

    Values of effective pulmonary blood flow (Q(EP)) and cardiac output, determined by a non-invasive foreign gas rebreathing method (CO(RB)) using a new infrared photoacoustic gas analysing system, were compared with measurements of cardiac output obtained by the direct Fick (CO(FICK)) and thermodil......Values of effective pulmonary blood flow (Q(EP)) and cardiac output, determined by a non-invasive foreign gas rebreathing method (CO(RB)) using a new infrared photoacoustic gas analysing system, were compared with measurements of cardiac output obtained by the direct Fick (CO...... with significant shunt flow. In the eight patients without significant shunt flow, the agreement between Q(EP) and CO(FICK) was 0.3 +/- 0.9 litre x min(-1). In conclusion, a foreign gas rebreathing method with a new infrared photoacoustic gas analyser provided at least as reliable a measure of cardiac output...... as did thermodilution. In the absence of significant shunt flow, measurement of Q(EP) itself provides a reliable estimate of cardiac output in heart failure patients. The infrared photoacoustic gas analyser markedly facilitates clinical use of the rebreathing method in general, which makes the method...

  12. Cardiac output assessment using oxygen consumption estimated from the left ventricular pressure-volume area.

    Science.gov (United States)

    Negroni, Jorge A; Lascano, Elena C; Bertolotti, Alejandro M; Gómez, Carmen B; Rodríguez Correa, Carlos A; Favaloro, Roberto R

    2010-01-01

    Use of a majority of structural variables (age, sex, height) to estimate oxygen consumption in the calculation of cardiac output (CO) by the Fick principle does not account for changes in physiological conditions. To improve this limitation, oxygen consumption was estimated based on the left ventricular pressure-volume area. A pilot study with 10 patients undergoing right cardiac catheterization showed that this approach was successful to estimate CO (r=0,73, vs. thermodilution measured CO). Further essays changing end-diastolic-volume in the pressure-volume area formula by body weight or body surface area showed that this last yielded the best correlation with the thermodilution measured CO (slope=1, ordinate =0.01 and r=0.93). These preliminary results indicate that use of a formula originated from the pressure-volume-area concept is a good alternative to estimate oxygen consumption for CO calculation.

  13. Evaluation of cardiac output from a tidally ventilated homogeneous lung model.

    Science.gov (United States)

    Benallal, Habib; Beck, Kenneth C; Johnson, Bruce D; Busso, Thierry

    2005-10-01

    We used the direct Fick measurements to validate a method for estimating cardiac output by iteratively fitting VCO(2) at the mouth to lung model values. This model was run using a series of 50, 30 and 10 breaths to test sensitivity to number of breaths used for fitting. The lung was treated as a catenary two-compartment lung model consisting of a dead space compartment connected with a single alveolar space compartment, perfused with constant pulmonary blood flow. The implemented mathematical modeling described variations in O(2) and CO(2) compartmental fractions and alveolar volume. This model also included pulmonary capillary gas exchange. Experimental data were collected from measurements performed on six healthy subjects at rest and during 20, 40, 60 and 85-90% of peak V(O)(2). The correlation between the two methods was highest and the average agreement between the methods was best using 50 breaths R = 095; P model) = 1.1Q(Fick) - 2.3). The mean difference and lower to upper limits of agreement between measured and estimated data were 0.7 l/min (-2.7 to 4.1 l/min) for cardiac output; -0.9 ml/100 ml (-1.3 to -0.5 ml/100 ml) for arterial O(2) content; -0.8 ml/100 ml (-3.8 to 2.2 ml/100 ml) for mixed venous O(2) content and -0.1 ml/100 ml (-2.9 to 2.7 ml/100 ml) for arteriovenous difference O(2) content. The cardiac output estimated by the lung model was in good agreement with the direct Fick measurements in young healthy subjects.

  14. NOTE: Increasing cardiac output and decreasing oxygenation sequence in pump twins of acardiac twin pregnancies

    Science.gov (United States)

    van Gemert, Martin J. C.; Umur, Asli; van den Wijngaard, Jeroen P. H. M.; Van Bavel, Ed; Vandenbussche, Frank P. H. A.; Nikkels, Peter G. J.

    2005-02-01

    An acardiac twin pregnancy is a rare but serious complication of monochorionic twinning and consists of an acardiac twin and a pump twin. The acardiac twin is a severely malformed fetus that lacks most organs, particularly a heart, but grows during pregnancy because it is perfused by the developmentally normal pump twin via a set of arterioarterial and venovenous placental anastomoses. Pump twins die intrauterine or neonatally in about 50% of the cases. Because the effects of an acardiac mass on the pump twin's development are incompletely known, methods for outcome prognosis are currently not available. We sought to derive simple relations for the pump twin's excess cardiac output and decreased oxygenation and to use available clinical cases for a preliminary test of the model. As a method, we used a theoretical flow model to represent the fetoplacental circulation of an acardiac twin pregnancy and estimated blood deoxygenation and reoxygenation following perfusion of the two bodies and placentas, respectively. The results show the pump twin's excess cardiac output and decrease of venous oxygen saturation to depend on the ratio of pump twin to acardiac twin umbilical blood flow, whose ratio can be measured by ultrasonography. The clinical cases show a decreasing umbilical flow ratio with gestation. In conclusion, prospective serial study is necessary to test whether measurement of umbilical flow ratios allows monitoring the pump twin's pathophysiologic development, possibly resulting in a guideline for prognosis of pump twin survival.

  15. Increasing cardiac output and decreasing oxygenation sequence in pump twins of acardiac twin pregnancies

    Energy Technology Data Exchange (ETDEWEB)

    Gemert, Martin J C van [Laser Center and Department of Obstetrics and Gynecology, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam (Netherlands); Umur, Asli [Laser Center and Department of Obstetrics and Gynecology, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam (Netherlands); Wijngaard, Jeroen P H M van den [Laser Center and Department of Obstetrics and Gynecology, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam (Netherlands); VanBavel, Ed [Department of Medical Physics, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands); Vandenbussche, Frank P H A [Department of Obstetrics, Leiden University Medical Center, Leiden (Netherlands); Nikkels, Peter G J [Department of Pathology, University Medical Center, Utrecht (Netherlands)

    2005-02-07

    An acardiac twin pregnancy is a rare but serious complication of monochorionic twinning and consists of an acardiac twin and a pump twin. The acardiac twin is a severely malformed fetus that lacks most organs, particularly a heart, but grows during pregnancy because it is perfused by the developmentally normal pump twin via a set of arterioarterial and venovenous placental anastomoses. Pump twins die intrauterine or neonatally in about 50% of the cases. Because the effects of an acardiac mass on the pump twin's development are incompletely known, methods for outcome prognosis are currently not available. We sought to derive simple relations for the pump twin's excess cardiac output and decreased oxygenation and to use available clinical cases for a preliminary test of the model. As a method, we used a theoretical flow model to represent the fetoplacental circulation of an acardiac twin pregnancy and estimated blood deoxygenation and reoxygenation following perfusion of the two bodies and placentas, respectively. The results show the pump twin's excess cardiac output and decrease of venous oxygen saturation to depend on the ratio of pump twin to acardiac twin umbilical blood flow, whose ratio can be measured by ultrasonography. The clinical cases show a decreasing umbilical flow ratio with gestation. In conclusion, prospective serial study is necessary to test whether measurement of umbilical flow ratios allows monitoring the pump twin's pathophysiologic development, possibly resulting in a guideline for prognosis of pump twin survival. (note)

  16. Cardiac output and vasodilation in the vasovagal response: An analysis of the classic papers.

    Science.gov (United States)

    Wieling, Wouter; Jardine, David L; de Lange, Frederik J; Brignole, Michele; Nielsen, Henning B; Stewart, Julian; Sutton, Richard

    2016-03-01

    The simple faint is secondary to hypotension and bradycardia resulting in transient loss of consciousness. According to Ohm's law applied to the circulation, BP = SVR × CO, hypotension can result from a decrease in systemic vascular resistance (SVR), cardiac output (CO), or both. It is important to understand that when blood pressure (BP) is falling, SVR and CO do not change reciprocally as they do in the steady state. In 1932, Lewis, assuming that decreased SVR alone accounted for hypotension, defined "the vasovagal response" along pathophysiologic lines to denote the association of vasodilation with vagal-induced bradycardia in simple faint. Studies performed by Barcroft and Sharpey-Schafer between 1940 and 1950 used volume-based plethysmography to demonstrate major forearm vasodilation during extreme hypotension and concluded that the main mechanism for hypotension was vasodilation. Plethysmographic measurements were intermittent and not frequent enough to capture rapid changes in blood flow during progressive hypotension. However, later investigations by Weissler, Murray, and Stevens performed between 1950 and 1970 used invasive beat-to-beat BP measurements and more frequent measurements of CO using the Fick principle. They demonstrated that CO significantly fell before syncope, and little vasodilation occurred until very late in the vasovagal reaction Thus, since the 1970s, decreasing cardiac output rather than vasodilation has been regarded as the principal mechanism for the hypotension of vasovagal syncope.

  17. Application of bioreactance for cardiac output assessment during exercise in healthy individuals.

    Science.gov (United States)

    Elliott, Adrian; Hull, James H; Nunan, David; Jakovljevic, Djordje G; Brodie, David; Ansley, Lesley

    2010-07-01

    In patients with cardiac failure, bioreactance-based cardiac output (CO) monitoring provides a valid non-invasive method for assessing cardiac performance during exercise. The purpose of this study was to evaluate the efficacy of this technique during strenuous exercise in healthy, trained individuals. Fourteen recreational cyclists, mean (SD) age of 34 (8) years and relative peak oxygen uptake of (VO(2)) 56 (6) ml kg(-1) min(-1), underwent incremental maximal exercise testing, whilst CO was recorded continuously using a novel bioreactance-based device (CO(bio)). The CO(bio) was evaluated against relationship with VO(2), theoretical calculation of arterial-venous oxygen difference (C(a - v) O(2)) and level of agreement with an inert gas rebreathing method (CO(rb)) using a Bland-Altman plot. Bioreactance-based CO measurement was practical and straightforward in application, although there was intermittent loss of electrocardiograph signal at high-intensity exercise. At rest and during exercise, CO(bio) was strongly correlated with VO(2) (r = 0.84; P < 0.001), however, there was evidence of systematic bias with CO(bio) providing lower values than CO(rb); mean bias (limits of agreement) -19% (14.6 to -53%). Likewise, calculated (C(a - v) O(2)) was greater when determined using CO(bio) than CO(rb) (P < 0.001), although both devices provided values in excess of those reported in invasive studies. Bioreactance-based determination of CO provides a pragmatic approach to the continuous assessment of cardiac performance during strenuous exercise in trained individuals. Our findings, however, suggest that further work is needed to refine the key measurement determinants of CO using this device to improve measurement accuracy in this setting.

  18. Differences between directly measured and calculated values for cardiac output in the dogfish: a criticism of the Fick method.

    Science.gov (United States)

    Metcalfe, J D; Butler, P J

    1982-08-01

    Cardiac output has been measured directly, and calculated by the Fick method, during normoxia and hypoxia in six artificially perfused dogfish (Scyliorhinus canicula) in an attempt to estimate the accuracy of this method in fish. The construction and operation of a simple extra-corporeal cardiac bypass pump is described. This pump closely mimics the flow pulse profiles of the fish's own heart and allows complete control of both cardiac stroke volume and systolic and diastolic periods. During normoxia (PO2 = 21 kPa) there was no significant difference between directly measured and calculated values for cardiac output. However, some shunting of blood past the respiratory surface of the gills may have been obscured by cutaneous oxygen uptake. In response to hypoxia (PO2 = 8.6 kPa) there is either a decrease in the amount of blood being shunted past the respiratory surface of the gills and/or an increase in cutaneous oxygen uptake such that the Fick calculated value for cardiac output is on average 38% greater than the measured value. It is proposed that the increase in the levels of circulating catecholamines that is reported to occur in response to hypoxia in this species may play an important role in the observed response to hypoxia. The results are discussed in terms of their implications for the calculation of cardiac output by the Fick principle in fish.

  19. Evaluation of a new arterial pressure-based cardiac output device requiring no external calibration

    Directory of Open Access Journals (Sweden)

    Amann Matthias

    2007-11-01

    Full Text Available Abstract Background Several techniques have been discussed as alternatives to the intermittent bolus thermodilution cardiac output (COPAC measurement by the pulmonary artery catheter (PAC. However, these techniques usually require a central venous line, an additional catheter, or a special calibration procedure. A new arterial pressure-based cardiac output (COAP device (FloTrac™, Vigileo™; Edwards Lifesciences, Irvine, CA, USA only requires access to the radial or femoral artery using a standard arterial catheter and does not need an external calibration. We validated this technique in critically ill patients in the intensive care unit (ICU using COPAC as the method of reference. Methods We studied 20 critically ill patients, aged 16 to 74 years (mean, 55.5 ± 18.8 years, who required both arterial and pulmonary artery pressure monitoring. COPAC measurements were performed at least every 4 hours and calculated as the average of 3 measurements, while COAP values were taken immediately at the end of bolus determinations. Accuracy of measurements was assessed by calculating the bias and limits of agreement using the method described by Bland and Altman. Results A total of 164 coupled measurements were obtained. Absolute values of COPAC ranged from 2.80 to 10.80 l/min (mean 5.93 ± 1.55 l/min. The bias and limits of agreement between COPAC and COAP for unequal numbers of replicates was 0.02 ± 2.92 l/min. The percentage error between COPAC and COAP was 49.3%. The bias between percentage changes in COPAC (ΔCOPAC and percentage changes in COAP (ΔCOAP for consecutive measurements was -0.70% ± 32.28%. COPAC and COAP showed a Pearson correlation coefficient of 0.58 (p PAC and ΔCOAP was 0.46 (p Conclusion Although the COAP algorithm shows a minimal bias with COPAC over a wide range of values in an inhomogeneous group of critically ill patients, the scattering of the data remains relative wide. Therefore, the used algorithm (V 1.03 failed to

  20. Left ventricular atrioventricular plane displacement is preserved with lifelong endurance training and is the main determinant of maximal cardiac output

    DEFF Research Database (Denmark)

    Steding-Ehrenborg, Katarina; Boushel, Robert C; Calbet, José A;

    2015-01-01

    BACKGROUND: Age-related decline in cardiac function can be prevented or postponed by lifelong endurance training. However, effects of normal ageing as well as of lifelong endurance exercise on longitudinal and radial contribution to stroke volume are unknown. The aim of this study was to determine...... resting longitudinal and radial pumping in elderly athletes, sedentary elderly and young sedentary subjects. Furthermore, we aimed to investigate determinants of maximal cardiac output in elderly. METHODS: 8 elderly athletes (63 ± 4 years), 7 elderly sedentary (66 ± 4 years) and 10 young sedentary...... subjects (29 ± 4 years) underwent cardiac MR. All subjects underwent maximal exercise testing and for elderly subjects maximal cardiac output during cycling was determined using dye dilution technique. RESULTS: Longitudinal and radial contribution to stroke volume did not differ between groups...

  1. Effect of heat stress on cardiac output and systemic vascular conductance during simulated hemorrhage to presyncope in young men

    DEFF Research Database (Denmark)

    Ganio, Matthew S; Overgaard, Morten; Seifert, Thomas;

    2012-01-01

    During moderate actual or simulated hemorrhage, as cardiac output decreases, reductions in systemic vascular conductance (SVC) maintain mean arterial pressure (MAP). Heat stress, however, compromises the control of MAP during simulated hemorrhage, and it remains unknown whether this response is due...... to a persistently high SVC and/or a low cardiac output. This study tested the hypothesis that an inadequate decrease in SVC is the primary contributing mechanism by which heat stress compromises blood pressure control during simulated hemorrhage. Simulated hemorrhage was imposed via lower body negative pressure...... (LBNP) to presyncope in 11 passively heat-stressed subjects (increase core temperature: 1.2 ± 0.2°C; means ± SD). Cardiac output was measured via thermodilution, and SVC was calculated while subjects were normothermic, heat stressed, and throughout subsequent LBNP. MAP was not changed by heat stress...

  2. Reference values for total blood volume and cardiac output in humans

    Energy Technology Data Exchange (ETDEWEB)

    Williams, L.R. [Indiana Univ., South Bend, IN (United States). Division of Liberal Arts and Sciences

    1994-09-01

    Much research has been devoted to measurement of total blood volume (TBV) and cardiac output (CO) in humans but not enough effort has been devoted to collection and reduction of results for the purpose of deriving typical or {open_quotes}reference{close_quotes} values. Identification of normal values for TBV and CO is needed not only for clinical evaluations but also for the development of biokinetic models for ultra-short-lived radionuclides used in nuclear medicine (Leggett and Williams 1989). The purpose of this report is to offer reference values for TBV and CO, along with estimates of the associated uncertainties that arise from intra- and inter-subject variation, errors in measurement techniques, and other sources. Reference values are derived for basal supine CO and TBV in reference adult humans, and differences associated with age, sex, body size, body position, exercise, and other circumstances are discussed.

  3. Non-invasive measurements of cardiac output in atrial fibrillation: Inert gas rebreathing and impedance cardiography

    DEFF Research Database (Denmark)

    Osbak, Philip S; Henriksen, Jens Henrik Sahl; Kofoed, Klaus F;

    2011-01-01

    Abstract Background. Atrial fibrillation (AF) is associated with significant morbidity and mortality. To test the effect of interventions, knowledge of cardiac output (CO) is important. However, the irregular heart rate might cause some methods for determination of CO to have inherent weaknesses....... Objective. To assess the validity of these methods in AF, a new inert gas rebreathing device and impedance cardiography was tested with echocardiography as reference. Methods. Using a cross-sectional design, 127 patients with AF and 24 in SR were consecutively recruited. Resting CO was measured using inert...... gas rebreathing (n = 62) or impedance measurement of intrathoracic blood flow (n = 89) in separate studies with echocardiographic measurement as reference. Results. CO determined with impedance cardiography was mean 4.77 L/min ± 2.24(SD) compared to 4.93 L/min ± 1.17 by echocardiography (n = 89, n...

  4. Chronic measurement of cardiac output in unanesthetized rats using miniature thermocouples.

    Science.gov (United States)

    Osborn, J W; Barber, B J; Quillen, E W; Abram, R J; Cowley, A W

    1986-12-01

    A thermodilution technique is described for measuring steady-state cardiac output (CO) in conscious rats for periods of 2-3 wk. The method utilizes small implantable aortic thermocouples inserted via the femoral artery at the time of placement of other chronic indwelling catheters. Data are presented to validate the accuracy and reproducibility of the technique by acute in situ comparison with electromagnetic flowmeter measurements. Responses in chronically instrumented rats were tested with hemorrhage and infusions of vasodilator and vasoconstrictor agents administered repeatedly over a period of 9 days. The results show that the system is capable of measuring CO chronically and provides reproducible responses for periods of at least several weeks. We conclude that these methods provide a single, inexpensive, and accurate way to measure steady-state CO in conscious, unrestrained rats.

  5. Low Cardiac Output Secondary to a Malpositioned Umbilical Venous Catheter: Value of Targeted Neonatal Echocardiography

    Directory of Open Access Journals (Sweden)

    Dany E. Weisz

    2014-05-01

    Full Text Available Systemic hypotension is common in very low birthweight preterm infants but the nature of the precipitating cause may be unclear. Targeted neonatal echocardiography (TnEcho is being increasingly used to support hemodynamic decisions in the neonatal intensive care unit (NICU, including identifying impairments in the transitional circulation of preterm infants, providing timely re-evaluation after institution of therapies and evaluating the placement of indwelling catheters. We present a case of a preterm infant with systemic hypotension and low cardiac output secondary to a large transatrial shunt induced by a malpositioned umbilical venous catheter. Repositioning of the line led to resolution of the hemodynamic disturbance and clinical instability, highlighting the utility of TnEcho in the NICU.

  6. Accuracy of Cardiac Output by Nine Different Pulse Contour Algorithms in Cardiac Surgery Patients: A Comparison with Transpulmonary Thermodilution

    Science.gov (United States)

    Bein, Berthold; Gruenewald, Matthias; Masing, Sarah; Huenges, Katharina; Haneya, Assad; Steinfath, Markus; Renner, Jochen

    2016-01-01

    Objective. Today, there exist several different pulse contour algorithms for calculation of cardiac output (CO). The aim of the present study was to compare the accuracy of nine different pulse contour algorithms with transpulmonary thermodilution before and after cardiopulmonary bypass (CPB). Methods. Thirty patients scheduled for elective coronary surgery were studied before and after CPB. A passive leg raising maneuver was also performed. Measurements included CO obtained by transpulmonary thermodilution (COTPTD) and by nine pulse contour algorithms (COX1–9). Calibration of pulse contour algorithms was performed by esophageal Doppler ultrasound after induction of anesthesia and 15 min after CPB. Correlations, Bland-Altman analysis, four-quadrant, and polar analysis were also calculated. Results. There was only a poor correlation between COTPTD and COX1–9 during passive leg raising and in the period before and after CPB. Percentage error exceeded the required 30% limit. Four-quadrant and polar analysis revealed poor trending ability for most algorithms before and after CPB. The Liljestrand-Zander algorithm revealed the best reliability. Conclusions. Estimation of CO by nine different pulse contour algorithms revealed poor accuracy compared with transpulmonary thermodilution. Furthermore, the less-invasive algorithms showed an insufficient capability for trending hemodynamic changes before and after CPB. The Liljestrand-Zander algorithm demonstrated the highest reliability. This trial is registered with NCT02438228 (ClinicalTrials.gov).

  7. Cardiac output in exercise by impedance cardiography during breath holding and normal breathing.

    Science.gov (United States)

    Du Quesnay, M C; Stoute, G J; Hughson, R L

    1987-01-01

    Estimation of cardiac output by impedance cardiography (QZ) in exercise during normal breathing (NB) has been limited by motion artifact. Our objective was to obtain readable impedance cardiograms on five subjects during upright cycle exercise at 0, 50, 100, 150, and 200 W to permit comparisons of QZ during NB, expiratory breath hold (EXP) and inspiratory breath hold (INSP). Q was also determined using an equilibration CO2 rebreathing method [Q(RB)]. QZ during NB exceeded EXP QZ at 100, 150, and 200 W, and exceeded INSP QZ at 100 W (P less than 0.05). The low EXP QZ values were due to a significantly lower stroke volume at 100, 150, and 200 W (P less than 0.05). For the INSP QZ at 100 W, heart rate was lower than during EXP (P less than 0.05). Regression of QZ (NB) against Q(RB) resulted in a linear relationship (r = 0.93) over the range of Q = 7-26 1/min. The slope of the regression differed significantly from 1.0 (P less than 0.05). We conclude that QZ values obtained during EXP or INSP should not be assumed to represent QZ during NB, at least at work rates greater than 50 W. A consequence of the linear relationship between QZ(NB) and Q(RB) over the range of 0-200 W is that estimates of CO2 rebreathing cardiac output can be obtained by impedance cardiography if QZ is adjusted using an appropriate empirical factor.

  8. Rowing increases stroke volume and cardiac output to a greater extent than cycling.

    Science.gov (United States)

    Horn, P; Ostadal, P; Ostadal, B

    2015-01-01

    Exercise stimulates increases in heart rate (HR), stroke volume (SV) and cardiac output (CO). These adaptive mechanisms are strongly dependent on the type of exercise. Both rowing and cycling are widely used for physical training worldwide; however, evidence regarding the differences in major hemodynamic parameters during rowing and cycling remains insufficient. Ten healthy male volunteers were randomly assigned to perform either a rowing or cycling exercise. After 20 min rest, the group who had rowed first performed the cycling exercise and vice versa. Exercise was performed at a power-to-weight ratio of 2 W/kg for 2 min. HR, SV, CO and blood pressure (BP) were measured noninvasively using pulse-wave analysis at baseline and immediately after each exercise. HR, SV and CO were significantly higher after exercise than at rest. Whereas HR was comparable between rowing and cycling, SV and CO were significantly higher after rowing than after cycling. BP was comparable among all three measurements. Rowing increased SV and CO to a greater extent than cycling, whereas HR and BP were not influenced by the type of exercise. Our data suggest that rowing leads to more extensive stimulation of cardiac contractility and/or decreases in peripheral vascular resistance compared with cycling.

  9. In vivo validation of cardiac output assessment in non-standard 3D echocardiographic images

    Science.gov (United States)

    Nillesen, M. M.; Lopata, R. G. P.; de Boode, W. P.; Gerrits, I. H.; Huisman, H. J.; Thijssen, J. M.; Kapusta, L.; de Korte, C. L.

    2009-04-01

    Automatic segmentation of the endocardial surface in three-dimensional (3D) echocardiographic images is an important tool to assess left ventricular (LV) geometry and cardiac output (CO). The presence of speckle noise as well as the nonisotropic characteristics of the myocardium impose strong demands on the segmentation algorithm. In the analysis of normal heart geometries of standardized (apical) views, it is advantageous to incorporate a priori knowledge about the shape and appearance of the heart. In contrast, when analyzing abnormal heart geometries, for example in children with congenital malformations, this a priori knowledge about the shape and anatomy of the LV might induce erroneous segmentation results. This study describes a fully automated segmentation method for the analysis of non-standard echocardiographic images, without making strong assumptions on the shape and appearance of the heart. The method was validated in vivo in a piglet model. Real-time 3D echocardiographic image sequences of five piglets were acquired in radiofrequency (rf) format. These ECG-gated full volume images were acquired intra-operatively in a non-standard view. Cardiac blood flow was measured simultaneously by an ultrasound transit time flow probe positioned around the common pulmonary artery. Three-dimensional adaptive filtering using the characteristics of speckle was performed on the demodulated rf data to reduce the influence of speckle noise and to optimize the distinction between blood and myocardium. A gradient-based 3D deformable simplex mesh was then used to segment the endocardial surface. A gradient and a speed force were included as external forces of the model. To balance data fitting and mesh regularity, one fixed set of weighting parameters of internal, gradient and speed forces was used for all data sets. End-diastolic and end-systolic volumes were computed from the segmented endocardial surface. The cardiac output derived from this automatic segmentation was

  10. In vivo validation of cardiac output assessment in non-standard 3D echocardiographic images

    Energy Technology Data Exchange (ETDEWEB)

    Nillesen, M M; Lopata, R G P; Gerrits, I H; Thijssen, J M; De Korte, C L [Clinical Physics Laboratory-833, Department of Pediatrics, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); De Boode, W P [Neonatology, Department of Pediatrics, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); Huisman, H J [Department of Radiology, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); Kapusta, L [Pediatric Cardiology, Department of Pediatrics, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands)], E-mail: m.m.nillesen@cukz.umcn.nl

    2009-04-07

    Automatic segmentation of the endocardial surface in three-dimensional (3D) echocardiographic images is an important tool to assess left ventricular (LV) geometry and cardiac output (CO). The presence of speckle noise as well as the nonisotropic characteristics of the myocardium impose strong demands on the segmentation algorithm. In the analysis of normal heart geometries of standardized (apical) views, it is advantageous to incorporate a priori knowledge about the shape and appearance of the heart. In contrast, when analyzing abnormal heart geometries, for example in children with congenital malformations, this a priori knowledge about the shape and anatomy of the LV might induce erroneous segmentation results. This study describes a fully automated segmentation method for the analysis of non-standard echocardiographic images, without making strong assumptions on the shape and appearance of the heart. The method was validated in vivo in a piglet model. Real-time 3D echocardiographic image sequences of five piglets were acquired in radiofrequency (rf) format. These ECG-gated full volume images were acquired intra-operatively in a non-standard view. Cardiac blood flow was measured simultaneously by an ultrasound transit time flow probe positioned around the common pulmonary artery. Three-dimensional adaptive filtering using the characteristics of speckle was performed on the demodulated rf data to reduce the influence of speckle noise and to optimize the distinction between blood and myocardium. A gradient-based 3D deformable simplex mesh was then used to segment the endocardial surface. A gradient and a speed force were included as external forces of the model. To balance data fitting and mesh regularity, one fixed set of weighting parameters of internal, gradient and speed forces was used for all data sets. End-diastolic and end-systolic volumes were computed from the segmented endocardial surface. The cardiac output derived from this automatic segmentation was

  11. Impact of pacing modality and biventricular pacing on cardiac output and coronary conduit flow in the post-cardiotomy patient.

    LENUS (Irish Health Repository)

    Healy, David G

    2012-02-03

    We have previously demonstrated the role of univentricular pacing modalities in influencing coronary conduit flow in the immediate post-operative period in the cardiac surgery patient. We wanted to determine the mechanism of this improved coronary conduit and, in addition, to explore the possible benefits with biventricular pacing. Sixteen patients undergoing first time elective coronary artery bypass grafting who required pacing following surgery were recruited. Comparison of cardiac output and coronary conduit flow was performed between VVI and DDD pacing with a single right ventricular lead and biventricular pacing lead placement. Cardiac output was measured using arterial pulse waveform analysis while conduit flow was measured using ultrasonic transit time methodology. Cardiac output was greatest with DDD pacing using right ventricular lead placement only [DDD-univentricular 5.42 l (0.7), DDD-biventricular 5.33 l (0.8), VVI-univentricular 4.71 l (0.8), VVI-biventricular 4.68 l (0.6)]. DDD-univentricular pacing was significantly better than VVI-univentricular (P=0.023) and VVI-biventricular pacing (P=0.001) but there was no significant advantage to DDD-biventricular pacing (P=0.45). In relation to coronary conduit flow, DDD pacing again had the highest flow [DDD-univentricular 55 ml\\/min (24), DDD-biventricular 52 ml\\/min (25), VVI-univentricular 47 ml\\/min (23), VVI-biventricular 50 ml\\/min (26)]. DDD-univentricular pacing was significantly better than VVI-univentricular (P=0.006) pacing but not significantly different to VVI-biventricular pacing (P=0.109) or DDD-biventricular pacing (P=0.171). Pacing with a DDD modality offers the optimal coronary conduit flow by maximising cardiac output. Biventricular lead placement offered no significant benefit to coronary conduit flow or cardiac output.

  12. [Anesthesia management of geriatric patients with arterial pressure-based cardiac output monitoring FloTrac sensor for emergency surgery].

    Science.gov (United States)

    Yamamoto, Shunsuke; Goto, Koji; Yasuda, Norihisa; Kusaka, Junya; Hidaka, Seigo; Miyakawa, Hiroshi; Noguchi, Takayuki

    2009-06-01

    In cases of emergency surgery for geriatric patients, immediate anesthesia induction and careful intraoperative management is necessary without sufficient preoperative information. We report anesthesia management of a 96-year and a 90-year old patients with FloTrac sensor which is an arterial pressure-based cardiac output monitoring device and is able to manage critical patients effectively and safely during anesthesia.

  13. Influence of lung injury on cardiac output measurement using transpulmonary ultrasound dilution: a validation study in neonatal lambs

    NARCIS (Netherlands)

    Vrancken, S.L.A.G.; Boode, W.P. de; Hopman, J.C.W.; Looijen-Salamon, M.G.; Liem, K.D.; Heijst, A.F. van

    2012-01-01

    BACKGROUND: /st> Transpulmonary ultrasound dilution (TPUD) is a promising method for cardiac output (CO) measurement in severely ill neonates. The incidence of lung injury in this population is high, which might influence CO measurement using TPUD because of altered lung perfusion. We evaluated t

  14. Finger arterial versus intrabrachial pressure and continuous cardiac output during head-up tilt testing in healthy subjects

    NARCIS (Netherlands)

    Jellema, W.T.; Imholz, B.P.M.; Goudoever, J. van; Wesseling, K.H.; Lieshout, J.J. van

    1996-01-01

    1. The aims of this study were to determine the clinical feasibility of continuous, non-invasive Finapres recordings as a replacement for intrabrachial pressure during a 30 min head-up tilt, and the reliability of continuous cardiac output computation by pulse contour analysis from the finger arteri

  15. ADRB2 gly16gly Genotype, Cardiac Output, and Cerebral Oxygenation in Patients Undergoing Anesthesia for Abdominal Aortic Aneurysm Surgery

    DEFF Research Database (Denmark)

    Staalso, Jonatan Myrup; Rokamp, Kim Zillo; Olesen, Niels D.

    2016-01-01

    BACKGROUND: Gly16arg polymorphism of the adrenergic [beta]2-receptor is associated with the elevated cardiac output (Q) in healthy gly16-homozygotic subjects. We questioned whether this polymorphism also affects Q and regional cerebral oxygen saturation (SCO2) during anesthesia in vascular surgic...

  16. Acoustic output of multi-line transmit beamforming for fast cardiac imaging: a simulation study.

    Science.gov (United States)

    Santos, Pedro; Tong, Ling; Ortega, Alejandra; Løvstakken, Lasse; Samset, Eigil; D'hooge, Jan

    2015-07-01

    Achieving higher frame rates in cardiac ultrasound could unveil short-lived myocardial events and lead to new insights on cardiac function. Multi-line transmit (MLT) beamforming (i.e., simultaneously transmitting multiple focused beams) is a potential approach to achieve this. However, two challenges come with it: first, it leads to cross-talk between the MLT beams, appearing as imaging artifacts, and second, it presents acoustic summation in the near field, where multiple MLT beams overlap. Although several studies have focused on the former, no studies have looked into the implications of the latter on acoustic safety. In this paper, the acoustic field of 4-MLT was simulated and compared with single-line transmit (SLT). The findings suggest that standard MLT does present potential concerns. Compared with SLT, it shows a 2-fold increase in mechanical index (MI) (from 1.0 to 2.3), a 6-fold increase in spatial-peak pulse-average intensity (I(sppa)) (from 99 to 576 W∙cm(-2)) and a 12-fold increase in spatial-peak temporalaverage intensity (I(spta)) (from 119 to 1407 mW∙cm(-2)). Subsequently, modifications of the transmit pulse and delay line of MLT were studied. These modifications allowed for a change in the spatio-temporal distribution of the acoustic output, thereby significantly decreasing the safety indices (MI = 1.2, I(sppa) = 92 W∙cm(-2) and I(spta) = 366 mW∙cm(-2)). Accordingly, they help mitigate the concerns around MLT, reducing potential tradeoffs between acoustic safety and image quality.

  17. Left ventricular atrioventricular plane displacement is preserved with lifelong endurance training and is the main determinant of maximal cardiac output.

    Science.gov (United States)

    Steding-Ehrenborg, Katarina; Boushel, Robert C; Calbet, José A; Åkeson, Per; Mortensen, Stefan P

    2015-12-01

    Age-related decline in cardiac function can be prevented or postponed by lifelong endurance training. However, effects of normal ageing as well as of lifelong endurance exercise on longitudinal and radial contribution to stroke volume are unknown. The aim of this study was to determine resting longitudinal and radial pumping in elderly athletes, sedentary elderly and young sedentary subjects. Furthermore, we aimed to investigate determinants of maximal cardiac output in elderly. Eight elderly athletes (63 ± 4 years), seven elderly sedentary (66 ± 4 years) and ten young sedentary subjects (29 ± 4 years) underwent cardiac magnetic resonance imaging. All subjects underwent maximal exercise testing and for elderly subjects maximal cardiac output during cycling was determined using a dye dilution technique. Longitudinal and radial contribution to stroke volume did not differ between groups (longitudinal left ventricle (LV) 52-65%, P = 0.12, right ventricle (RV) 77-87%, P = 0.16, radial 7.9-8.6%, P = 1.0). Left ventricular atrioventricular plane displacement (LVAVPD) was higher in elderly athletes and young sedentary compared with elderly sedentary subjects (14 ± 3, 15 ± 2 and 11 ± 1 mm, respectively, P cardiac output (R(2) = 0.61, P Longitudinal and radial contributions to stroke volume did not differ between groups. However, how longitudinal pumping was achieved differed; elderly athletes and young sedentary subjects showed similar AVPD whereas this was significantly lower in elderly sedentary subjects. Elderly sedentary subjects achieved longitudinal pumping through increased short-axis area of the ventricle. Large AVPD was a determinant of maximal cardiac output and exercise capacity.

  18. A computational model-based validation of Guyton's analysis of cardiac output and venous return curves

    Science.gov (United States)

    Mukkamala, R.; Cohen, R. J.; Mark, R. G.

    2002-01-01

    Guyton developed a popular approach for understanding the factors responsible for cardiac output (CO) regulation in which 1) the heart-lung unit and systemic circulation are independently characterized via CO and venous return (VR) curves, and 2) average CO and right atrial pressure (RAP) of the intact circulation are predicted by graphically intersecting the curves. However, this approach is virtually impossible to verify experimentally. We theoretically evaluated the approach with respect to a nonlinear, computational model of the pulsatile heart and circulation. We developed two sets of open circulation models to generate CO and VR curves, differing by the manner in which average RAP was varied. One set applied constant RAPs, while the other set applied pulsatile RAPs. Accurate prediction of intact, average CO and RAP was achieved only by intersecting the CO and VR curves generated with pulsatile RAPs because of the pulsatility and nonlinearity (e.g., systemic venous collapse) of the intact model. The CO and VR curves generated with pulsatile RAPs were also practically independent. This theoretical study therefore supports the validity of Guyton's graphical analysis.

  19. Kinetics of Cardiac Output at the Onset of Exercise in Precapillary Pulmonary Hypertension

    Science.gov (United States)

    Bengueddache, Samir; Ferretti, Guido; Soccal, Paola M.; Noble, Stéphane; Beghetti, Maurice; Chemla, Denis; Hervé, Philippe; Sitbon, Olivier

    2016-01-01

    Purpose. Cardiac output (CO) is a cornerstone parameter in precapillary pulmonary hypertension (PH). The Modelflow (MF) method offers a reliable noninvasive determination of its beat-by-beat changes. So MF allows exploration of CO adjustment with the best temporal resolution. Methods. Fifteen subjects (5 PH patients, 10 healthy controls) performed a submaximal supine exercise on a cycle ergometer after 5 min of rest. CO was continuously determined by MF (COMF). Kinetics of heart rate (HR), stroke volume (SV), and CO were determined with 3 monoexponential models. Results. In PH patients, we observed a sudden and transitory drop of SV upon exercise onset. This implied a transitory drop of CO whose adjustment to a new steady state depended on HR increase. The kinetics of HR and CO for PH patients was slower than that of controls for all models and for SV in model 1. SV kinetics was faster for PH patients in models 2 and 3. Conclusion. This is the first description of beat-by-beat cardiovascular adjustments upon exercise onset in PH. The kinetics of HR and CO appeared slower than those of healthy controls and there was a transitory drop of CO upon exercise onset in PH due to a sudden drop of SV. PMID:27990432

  20. Kinetics of Cardiac Output at the Onset of Exercise in Precapillary Pulmonary Hypertension

    Directory of Open Access Journals (Sweden)

    Frédéric Lador

    2016-01-01

    Full Text Available Purpose. Cardiac output (CO is a cornerstone parameter in precapillary pulmonary hypertension (PH. The Modelflow (MF method offers a reliable noninvasive determination of its beat-by-beat changes. So MF allows exploration of CO adjustment with the best temporal resolution. Methods. Fifteen subjects (5 PH patients, 10 healthy controls performed a submaximal supine exercise on a cycle ergometer after 5 min of rest. CO was continuously determined by MF (COMF. Kinetics of heart rate (HR, stroke volume (SV, and CO were determined with 3 monoexponential models. Results. In PH patients, we observed a sudden and transitory drop of SV upon exercise onset. This implied a transitory drop of CO whose adjustment to a new steady state depended on HR increase. The kinetics of HR and CO for PH patients was slower than that of controls for all models and for SV in model 1. SV kinetics was faster for PH patients in models 2 and 3. Conclusion. This is the first description of beat-by-beat cardiovascular adjustments upon exercise onset in PH. The kinetics of HR and CO appeared slower than those of healthy controls and there was a transitory drop of CO upon exercise onset in PH due to a sudden drop of SV.

  1. Cardiac Output Measurements in Septic Patients: Comparing the Accuracy of USCOM to PiCCO

    Directory of Open Access Journals (Sweden)

    Sophia Horster

    2012-01-01

    Full Text Available USCOM is an ultrasound-based method which has been accepted for noninvasive hemodynamic monitoring in various clinical conditions (USCOM, Ultrasonic cardiac output monitoring. The present study aimed at comparing the accuracy of the USCOM device with that of the thermodilution technique in patients with septicemia. We conducted a prospective observational study in a medical but noncardiological ICU of a university hospital. Septic adult patients (median age 55 years, median SAPS-II-Score 43 points on mechanical ventilation and catecholamine support were monitored with USCOM and PiCCO (=70. Seventy paired left-sided CO measurements (transaortic access = COUS-A were obtained. The mean COUS-A were 6.55 l/min (±2.19 versus COPiCCO 6.5 l/min (±2.18. The correlation coefficient was =0.89. Comparison by Bland-Altman analysis revealed a bias of −0.36 l/min (±0.99 l/min leading to a mean percentage error of 29%. USCOM is a feasible and rapid method to evaluate CO in septic patients. USCOM does reliably represent CO values as compared to the reference technique based on thermodilution (PiCCO. It seems to be appropriate in situations where CO measurements are most pertinent to patient management.

  2. Cardiac output and associated left ventricular hypertrophy in pediatric chronic kidney disease.

    Science.gov (United States)

    Weaver, Donald J; Kimball, Thomas R; Koury, Phillip R; Mitsnefes, Mark M

    2009-03-01

    A significant number of children with chronic kidney disease (CKD) have eccentric left ventricular hypertrophy (LVH), suggesting the role of preload overload. Therefore, we hypothesized that increased cardiac output (CO) might be a contributing factor for increased left ventricular mass index (LVMI) in these children. Patients aged 6-20 years with CKD stages 2-4 were enrolled. Echocardiograms were performed to assess LV function and geometry at rest and during exercise. Heart rate, stroke volume, and CO were also assessed at rest and during exercise. Twenty-four-hour ambulatory blood pressure (AMBP) monitoring was performed. Of the patients enrolled in this study, 17% had LVH. Increased stroke volume and CO were observed in patients with LVH compared to patients without LVH. Univariate analysis revealed significant positive associations between LVMI and CO, stroke volume, body mass index, pulse pressure from mean 24-h AMBP, and mean 24-h systolic BP load. No association with heart rate, age, parathyroid hormone, glomerular filtration rate, or anemia was observed. Only CO (beta = 1.98, p = 0.0005) was independently associated with increased LVMI in multivariate modeling (model R (2) = 0.25). The results of this study suggest that increased CO might predispose to increased LVMI in pediatric patients with CKD. Adaptations may be required to meet increased metabolic demand in these patients.

  3. High Output Cardiac Failure Resolving after Repair of AV Fistula in a Six-Month-Old

    Directory of Open Access Journals (Sweden)

    Uygar Teomete

    2016-01-01

    Full Text Available Background. Acquired AVF in pediatrics are commonly caused by iatrogenic means, including arterial or venous punctures. These fistulae can cause great hemodynamic stress on the heart as soon as they are created. Case. A six-month-old 25-week gestation infant was referred for respiratory distress. Initial exam revealed tachypnea, tachycardia, and hypertension. There was a bruit noted on her left arm. An ultrasound showed an arteriovenous fistula. Its location, however, precluded intervention because of the high risk for limb-loss. An echocardiogram showed evidence of pulmonary hypertension that was treated with sildenafil and furosemide. However, no improvement was seen. On temporary manual occlusion of the fistula, the patient was noted to have increased her blood pressure and decreased her heart rate, suggesting significant hemodynamic effect of the fistula. The fistula was subsequently ligated and the patient clinically and echocardiographically improved. Conclusion. A patient in high output cardiac failure or pulmonary artery hypertension, especially prematüre patients with preexisting lung disease, should be probed for history of multiple punctures, trauma, or surgery and should have prompt evaluation for AVF. If it can be diagnosed and repaired, most of the cases have been shown to decrease the stress on the heart and reverse the pathologic hemodynamics.

  4. High Output Cardiac Failure Resolving after Repair of AV Fistula in a Six-Month-Old

    Science.gov (United States)

    Teomete, Uygar; Gugol, Rubee Anne; Neville, Holly; Dandin, Ozgur; Young, Ming-Lon

    2016-01-01

    Background. Acquired AVF in pediatrics are commonly caused by iatrogenic means, including arterial or venous punctures. These fistulae can cause great hemodynamic stress on the heart as soon as they are created. Case. A six-month-old 25-week gestation infant was referred for respiratory distress. Initial exam revealed tachypnea, tachycardia, and hypertension. There was a bruit noted on her left arm. An ultrasound showed an arteriovenous fistula. Its location, however, precluded intervention because of the high risk for limb-loss. An echocardiogram showed evidence of pulmonary hypertension that was treated with sildenafil and furosemide. However, no improvement was seen. On temporary manual occlusion of the fistula, the patient was noted to have increased her blood pressure and decreased her heart rate, suggesting significant hemodynamic effect of the fistula. The fistula was subsequently ligated and the patient clinically and echocardiographically improved. Conclusion. A patient in high output cardiac failure or pulmonary artery hypertension, especially prematüre patients with preexisting lung disease, should be probed for history of multiple punctures, trauma, or surgery and should have prompt evaluation for AVF. If it can be diagnosed and repaired, most of the cases have been shown to decrease the stress on the heart and reverse the pathologic hemodynamics. PMID:26885434

  5. High Output Cardiac Failure Resolving after Repair of AV Fistula in a Six-Month-Old.

    Science.gov (United States)

    Teomete, Uygar; Gugol, Rubee Anne; Neville, Holly; Dandin, Ozgur; Young, Ming-Lon

    2016-01-01

    Background. Acquired AVF in pediatrics are commonly caused by iatrogenic means, including arterial or venous punctures. These fistulae can cause great hemodynamic stress on the heart as soon as they are created. Case. A six-month-old 25-week gestation infant was referred for respiratory distress. Initial exam revealed tachypnea, tachycardia, and hypertension. There was a bruit noted on her left arm. An ultrasound showed an arteriovenous fistula. Its location, however, precluded intervention because of the high risk for limb-loss. An echocardiogram showed evidence of pulmonary hypertension that was treated with sildenafil and furosemide. However, no improvement was seen. On temporary manual occlusion of the fistula, the patient was noted to have increased her blood pressure and decreased her heart rate, suggesting significant hemodynamic effect of the fistula. The fistula was subsequently ligated and the patient clinically and echocardiographically improved. Conclusion. A patient in high output cardiac failure or pulmonary artery hypertension, especially prematüre patients with preexisting lung disease, should be probed for history of multiple punctures, trauma, or surgery and should have prompt evaluation for AVF. If it can be diagnosed and repaired, most of the cases have been shown to decrease the stress on the heart and reverse the pathologic hemodynamics.

  6. Estimation of cardiac output and peripheral resistance using square-wave-approximated aortic flow signal

    Directory of Open Access Journals (Sweden)

    Nima eFazeli

    2012-07-01

    Full Text Available This paper presents a model-based approach to estimation of cardiac output (CO and total peripheral resistance (TPR. In the proposed approach, the response of cardiovascular system (CVS, described by the windkessel model, is tuned to the measurements of systolic, diastolic and mean arterial blood pressures (BP so as to yield optimal individual- and time-specific system time constant that is used to estimate CO and TPR. Unique aspects of the proposed approach are that it approximates the aortic flow as a train of square waves, and that it also assumes pressure-dependent arterial compliance, as opposed to the traditional windkessel model in which aortic flow is approximated as a train of impulses and constant arterial compliance is assumed. It was shown that the proposed model encompasses the standard windkessel model as a limiting case, and that it also yields more realistic BP waveform response than the standard windkessel model. The proposed approach has potential to outperform its standard counterpart by treating systolic, diastolic and mean BP as independent features in estimating CO and TPR, rather than solely resorting to pulse pressure as in the case of the standard windkessel model. Experimental results from in-vivo data collected from a number of animal subjects supports the viability of the proposed approach in that it could achieve approximately 29% and 24% reduction in CO and TPR errors when compared with its standard counterpart.

  7. Resistance reconstructed estimation of total peripheral resistance from computationally derived cardiac output - biomed 2013.

    Science.gov (United States)

    Hill, Labarron K; Sollers Iii, John J; Thayer, Julian F

    2013-01-01

    Efficient functioning of the peripheral vasculature is an essential component in healthy cardiovascular regulation. Alterations in this functioning have been linked to the etiology and pathophysiological course of cardiovascular disease (CVD), especially hypertension. Given its significant role in the maintenance of both healthy and pathological blood pressure, total peripheral resistance (TPR), an index of the vasoconstrictive and elastic properties of the peripheral vasculature, has received much attention in this regard. However, obtaining a reliable estimate of TPR remains a complex and costly endeavor, primarily due to the necessity for sophisticated instrumentation as well as associated limitations in deriving cardiac output (CO). We have previously described a simple estimation method for CO using only arterial blood pressure and heart rate (Hill et al, 2012). In the present study we extend this technique to the estimation of TPR using beat-to-beat blood pressure data from the same sample of 67 young (mean age = 20.04± 2.8), healthy men (n = 30) and women (n = 37). Estimated TPR (TPRest) was calculated from the computationally-derived estimate of CO and mean arterial pressure (MAP). Correlation between TPR obtained via the validated Model-Flow technique and TPRest was moderate (r =.73, p <. 000) and stronger in men (r =.78, p <. 000) compared to women (r =.66, p <. 001). These data further suggest that reconstructed measures of hemodynamic functioning may be validly and adequately estimated from limited data sources.

  8. Dynamic vs. fixed bag filling: impact on cardiac output rebreathing protocol.

    Science.gov (United States)

    Zavorsky, Gerald S; Beck, Kenneth C; Cass, Lauren M; Artal, Raul; Wagner, Peter D

    2010-04-15

    The purpose of this study was to compare the repeatability (2.77 multiplied by the within-subject SD)between two different rebreathing protocols on cardiac output ( ˙Q ), pulmonary diffusing capacity for carbon monoxide (DLCO) and nitric oxide (DLNO), and pulmonary capillary blood volume (Vc). This study compared two bag volume protocols [Fixed Bag Volume (FBV) = bag volume fixed at 60% of forced vital capacity; Dynamic Bag Volume (DBV) = bag volume matched to tidal volume at each stage of exercise].Ten females (age = 27±8 yrs; ˙VO2, (peak)=2.5±0.6 L/min had measurements at rest (12%), 52%, 88%, and 100% of ˙VO2, (peak) on two study days. Neither the slope nor intercept of ˙Q vs. ˙VO2 were different between either bag volume protocols. The slope of DLCO vs. ˙Q was the same but the intercept was higher for the FBV protocol. The bag volume affected the slope and the intercept between DLNO vs. ˙Q (p DLNO (p ≤ 0.06). Measurement error was lower for Vc when using the FBV protocol (p = 0.02). Also, the pattern of bag volume used during rebreathing maneuvers affected the relation between DLNO vs. ˙Q more than it affected DLCO vs. ˙Q , or Vc vs. ˙Q. Additionally, the FBV protocol provided less measurement error for Vc compared to the DBV protocol [corrected].

  9. Low Cardiac Output Leads Hepatic Fibrosis in Right Heart Failure Model Rats.

    Directory of Open Access Journals (Sweden)

    Yoshitaka Fujimoto

    Full Text Available Hepatic fibrosis progresses with right heart failure, and becomes cardiac cirrhosis in a severe case. Although its causal factor still remains unclear. Here we evaluated the progression of hepatic fibrosis using a pulmonary artery banding (PAB-induced right heart failure model and investigated whether cardiac output (CO is responsible for the progression of hepatic fibrosis.Five-week-old Sprague-Dawley rats divided into the PAB and sham-operated control groups. After 4 weeks from operation, we measured CO by echocardiography, and hepatic fibrosis ratio by pathological examination using a color analyzer. In the PAB group, CO was significantly lower by 48% than that in the control group (78.2±27.6 and 150.1±31.2 ml/min, P<0.01. Hepatic fibrosis ratio and serum hyaluronic acid, an index of hepatic fibrosis, were significantly increased in the PAB group than those in the control group (7.8±1.7 and 1.0±0.2%, P<0.01, 76.2±27.5 and 32.7±7.5 ng/ml, P<0.01. Notably, the degree of hepatic fibrosis significantly correlated a decrease in CO. Immunohistological analysis revealed that hepatic stellate cells were markedly activated in hypoxic areas, and HIF-1α positive hepatic cells were increased in the PAB group. Furthermore, by real-time PCR analyses, transcripts of profibrotic and fibrotic factors (TGF-β1, CTGF, procollargen I, procollargen III, MMP 2, MMP 9, TIMP 1, TIMP 2 were significantly increased in the PAB group. In addition, western blot analyses revealed that the protein level of HIF-1α was significantly increased in the PAB group than that in the control group (2.31±0.84 and 1.0±0.18 arbitrary units, P<0.05.Our study demonstrated that low CO and tissue hypoxia were responsible for hepatic fibrosis in right failure heart model rats.

  10. [Echocardiographic evaluation of cardiac output in patients with acute myocardial infarction (author's transl)].

    Science.gov (United States)

    Nador, F; De Martini, M; Binda, A; Salmaso, G C; Radrizzani, D; Lotto, A

    1980-01-01

    Echocardiography is a non invasive technique particularly useful to assess both hemodynamics and left ventricular performances; different methods have been proposed to evaluate echocardiographically the cardiac output. The aim of this work is to suggest a new method (planimetry of the area enclosed by echoes from the mitral valve) stating its advantages and limits and to test three already known methods (cubes method, method of Lalani and Lee, method of Rasmussen and coll.) comparing them to thermodilution. In 24 patients admitted in our Coronary Care Unit for acute myocardial infarction 30 measurements have been performed simultaneously with echocardiography and thermodilution. Statistical analysis (correlation coefficient with the method of the square minimums and Student's 't') of the results has shown that the cubes method is unprecise (P = NS) and unbiased (d = 0.97 +/- 15.46); Lalani-Lee method is unprecise (P = NS) and biased (d = 9.64 +/- 21.36) by a systematic underestimate error concealed by the poor precision; Rasmussen and coll. method is precise (P < 0.01) but biased (d = --3.03 +/- 5.5), the systematic mistake being entirely due to the group of patients with abnormal hemodynamics. Our method is precise (P < 0.01) and unbiased (d = --0.04 +/- 9.62) in patients both with normal and abnormal hemodynamics. Therefore this method offers the following advantages: 1) it is unbiased, even in the presence of abnormal left ventricular performance; 2) it is sufficiently precise, having a correlation coefficient with thermodilution of r = 0.80; 3) it measures directly the amount of flow due to the atrial systole; 4) the measurement is rapid and hardly biased by the reader.

  11. Comparison of cardiac output determined by different rebreathing methods at rest and at peak exercise.

    Science.gov (United States)

    Jakovljevic, Djordje G; Nunan, David; Donovan, Gay; Hodges, Lynette D; Sandercock, Gavin R H; Brodie, David A

    2008-03-01

    Several rebreathing methods are available for cardiac output (Q (T)) measurement. The aims of this study were threefold: first, to compare values for resting Q (T) produced by the equilibrium-CO(2), exponential-CO(2) and inert gas-N(2)O rebreathing methods and, second, to evaluate the reproducibility of these three methods at rest. The third aim was to assess the agreement between estimates of peak exercise Q (T) derived from the exponential and inert gas rebreathing methods. A total of 18 healthy subjects visited the exercise laboratory on different days. Repeated measures of Q (T), measured in a seated position, were separated by a 5 min rest period. Twelve participants performed an incremental exercise test to determine peak oxygen consumption. Two more exercise tests were used to measure Q (T) at peak exercise using the exponential and inert gas rebreathing methods. The exponential method produced significantly higher estimates at rest (averaging 10.9 l min(-1)) compared with the equilibrium method (averaging 6.6 l min(-1)) and the inert gas rebreathing method (averaging 5.1 l min(-1); P < 0.01). All methods were highly reproducible with the exponential method having the largest coefficient of variation (5.3%). At peak exercise, there were non-significant differences between the exponential and inert gas rebreathing methods (P = 0.14). The limits of agreement were -0.49 to 0.79 l min(-1). Due to the ability to evaluate the degree of gas mixing and to estimate intra-pulmonary shunt, we believe that the inert gas rebreathing method has the potential to measure Q (T) more precisely than either of the CO(2) rebreathing methods used in this study. At peak exercise, the exponential and inert gas rebreathing methods both showed acceptable limits of agreement.

  12. Predictors of Post Pericardiotomy Low Cardiac Output Syndrome in Patients With Pericardial Effusion

    Directory of Open Access Journals (Sweden)

    Sabzi Feridoun

    2015-03-01

    Full Text Available Introduction: Pathological involvement of pericardium by any disease that resulting in effusion may require decompression and pericardiectomy. The current article describes rare patients with effusion who after pericadiectomy and transient hemodynamic improvement rapidly developed progressive heart failure and subsequent multi organ failure.Methods: During periods of five years, 423 patients in our hospital underwent pericardiotomy for decompression of effusion. The clinical characteristics of those patient with postoperative low cardiac output (B group (14 cases recorded and compared with other patients without this postoperative complication (A group by test and X2. Significant variables in invariables (P≤0.1 entered in logistic regression analysis and odd ratio of these significant variables obtained. Results: Idiopathic pericardial effusion, malignancy, renal failure, connective tissue disease, viral pericarditis was found in 125 patients (27%, 105 patients (25.4%, 65 patients (15.6%, 50 (17.1% and 10 (2.4% of patients subsequently. The factors that predict post-operative death in logistic regression analysis were malignancy, radiotherapy, constrictive pericarditis inotropic drug using IABP using, pre-operative EF and pericardial calcification.Conclusion: Certain preoperative variables such as malignancy, radiotherapy, low EF, calcified pericardium and connective tissue disease are associated with POLCOS and post-operative risk of death. This paradoxical response to pericardial decompression may be more frequent than currently appreciated. Its cause may relate to the sudden removal of the chronic external ventricular support from the effusion or thicken pericardium resulting in ventricular dilatation and failure or intra operative myocardial injury due to pericardiectomy of calcified pericardium, radiation and cardiomyopathy.

  13. Low cardiac output predicts development of hepatorenal syndrome and survival in patients with cirrhosis and ascites

    DEFF Research Database (Denmark)

    Krag, A; Bendtsen, F; Henriksen, J H;

    2010-01-01

    OBJECTIVES: Recent studies suggest that cardiac dysfunction precedes development of the hepatorenal syndrome. In this follow-up study, we aimed to investigate the relation between cardiac and renal function in patients with cirrhosis and ascites and the impact of cardiac systolic function...... on survival. Patients and DESIGN: Twenty-four patients with cirrhosis and ascites were included. Cardiac function was investigated by gated myocardial perfusion imaging (MPI) for assessment of cardiac index (CI) and cardiac volumes. The renal function was assessed by determination of glomerular filtration...... (130 (SD 46) vs 78 (SD 29) mumol/l, pdeveloped hepatorenal syndrome type 1 within 3 months was higher in the group with low CI than in the high CI group (43% vs 5%, p = 0.04). Patients with the lowest CI (N = 8) had significantly poorer survival at 3, 9, and 12 months...

  14. Non-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing technique.

    Science.gov (United States)

    Gabrielsen, Anders; Videbaek, Regitze; Schou, Morten; Damgaard, Morten; Kastrup, Jens; Norsk, Peter

    2002-02-01

    Values of effective pulmonary blood flow (Q(EP)) and cardiac output, determined by a non-invasive foreign gas rebreathing method (CO(RB)) using a new infrared photoacoustic gas analysing system, were compared with measurements of cardiac output obtained by the direct Fick (CO(FICK)) and thermodilution (CO(TD)) methods in patients with heart failure or pulmonary hypertension. In 11 patients, of which three had shunt flow through areas without significant gas exchange, the mean difference (bias) and limits of agreement (+/- 2 S.D.) were 0.6 +/- 1.2 litre x min(-1) when comparing CO(FICK) and Q(EP), and -0.8 +/- 1.3 litre x min(-1) when comparing CO(FICK) and CO(TD). When correction for intrapulmonary shunt flow was applied (i.e. calculation of CO(RB)) in all 11 patients, the bias between CO(FICK) and CO(RB) was 0.1 +/- 0.9 litre x min(-1), primarily because agreement improved in the three patients with significant shunt flow. In the eight patients without significant shunt flow, the agreement between Q(EP) and CO(FICK) was 0.3 +/- 0.9 litre x min(-1). In conclusion, a foreign gas rebreathing method with a new infrared photoacoustic gas analyser provided at least as reliable a measure of cardiac output as did thermodilution. In the absence of significant shunt flow, measurement of Q(EP) itself provides a reliable estimate of cardiac output in heart failure patients. The infrared photoacoustic gas analyser markedly facilitates clinical use of the rebreathing method in general, which makes the method available to a larger group of clinicians working with patients with cardiovascular diseases.

  15. Clinical review: Guyton - the role of mean circulatory filling pressure and right atrial pressure in controlling cardiac output

    OpenAIRE

    William R Henderson; Griesdale, Donald EG; Walley, Keith R; Sheel, A. William

    2010-01-01

    Arthur Guyton's concepts of the determinative role of right heart filling in cardiac output continue to be controversial. This paper reviews his seminal experiments in detail and clarifies the often confusing concepts underpinning his model. One primary criticism of Guyton's model is that the parameters describing venous return had not been measured in a functioning cardiovascular system in humans. Thus, concerns have been expressed in regard to the ability of Guyton's simplistic model, with ...

  16. Combined use of phenoxybenzamine and dopamine for low cardiac output syndrome in children at withdrawal from cardiopulmonary bypass.

    OpenAIRE

    Kawamura, M.; Minamikawa, O; Yokochi, H; Maki, S.; Yasuda, T.; Mizukawa, Y

    1980-01-01

    The combined use of phenoxybenzamine and dopamine was applied in infants and children when it was difficult to come off cardiopulmonary bypass for low cardiac output. The rationale of this method is to prevent the alpha-adrenergic action of dopamine by phenoxybenzamine and to encourage the beta-adrenergic and direct specific action of dopamine. Dopamine was used in dosage of 10 to 30 micrograms/kg per min after the additional administration of a half of the initial dosage of phenoxybenzamine;...

  17. Signal processing technique for non-invasive real-time estimation of cardiac output by inductance cardiography (thoracocardiography).

    Science.gov (United States)

    Bucklar, G B; Kaplan, V; Bloch, K E

    2003-05-01

    Inductance cardiography (thoracocardiography) non-invasively monitors changes in stroke volume by recording ventricular volume curves with an inductive plethysmographic transducer encircling the chest at the level of the heart. Clinical application of this method has been hampered, as data analysis has not been feasible in real time. Therefore a novel, real-time signal processing technique for inductance cardiography has been developed. Its essential concept consists in performance of multiple tasks by several, logically linked signal processing modules that have access to common databases. Based on these principles, a software application was designed that performs acquisition, display, filtering and ECG-triggered ensemble averaging of inductance signals and separates cardiogenic waveforms from noise related to respiration and other sources. The resulting ventricular volume curves are automatically analysed. Performance of the technique for monitoring cardiac output in real time was compared with thermodilution in four patients in an intensive care unit. The bias (mean difference) among 76 paired thoracocardiographic and thermodilution derived changes in cardiac output was 0%; limits of agreement (+/- 2 SD of the bias) were +/- 25%. It is concluded that the proposed signal processing technique for inductance cardiography holds promise for non-invasive, real-time estimation of changes in cardiac output.

  18. Effect of hemorrhage on cardiac output, vasopressin, aldosterone, and diuresis during immersion in men

    Science.gov (United States)

    Greenleaf, J. E.; Simanonok, K.; Bernauer, E. M.; Wade, C. E.; Keil, L. C.

    1992-01-01

    The purpose of this research was to test the hypotesis that a reduction in blood volume would attenuate or eliminate immersion-induced increases in cardiac output (Q(sub co)) and urine excretion, and to investigate accompanying vasoactive and fluid-electrolyte hormonal responses. Eight men (19-23 yr) were supine during a 2-hr control period in air, and then sat for 5-hr test periods in air at 20 C (dry control, DC); water at 34.5 C (wet control, WC); and water (34.5 C) after hemorrhage (WH) of 14.8 plus or minus 0.3 percent of their blood volume. Blood volume was -11.6 plus or minus 0.6 percent at immersion (time 0). Mean (bar-X hrs 1-5) Q(sub co) was unchanged in WC (5.3 plus or minus 0.01 l/min) and in WH (4.5 plus or minus 0.1 l/min), but decreased (P less than 0.05) in DC to 3.6 plus or minus 0.1 l/min. Mean urine excretion rates were 1.0 plus or minus 0.2 ml/min for DC and 1.1 plus or minus 0.2 ml/min for WH; both were lower (P less than 0.05) than that for WC of 2.0 plus or minus 0.4 ml/min. Plasma (Na+) and (Osm) were unchanged in all experiments. Mean plasma vasopressin (PVP) (bar-X hrs 1-5) was 1.1 plus or minus 0.1 pg/ml in WC, and higher (P less than 0.05) in DC (2.1 plus or minus 0.2 pg/ml)and WH (2.1 plus or minus 0.1 pg/ml); it was unchanged during air and water test periods. Thus, hemorrhage attenuated the immersion-induced increase in Q(sub co), eliminated the WC diuresis, maintained plasma renin activity and PVP at DC levels and did not change immersion-induced aldosterone suppression; the osmotic diuresis during control immersion is apparently not due to either aldosterone suppression or vasopressin suppression.

  19. Femoral Blood Flow and Cardiac Output During Blood Flow Restricted Leg Press Exercise

    Science.gov (United States)

    Everett, M. E.; Hackney, K.; Ploutz-Snyder, L.

    2011-01-01

    Low load blood flow restricted resistance exercise (LBFR) causes muscle hypertrophy that may be stimulated by the local ischemic environment created by the cuff pressure. However, local blood flow (BF) during such exercise is not well understood. PURPOSE: To characterize femoral artery BF and cardiac output (CO) during leg press exercise (LP) performed at a high load (HL) and low load (LL) with different levels of cuff pressure. METHODS: Eleven subjects (men/women 4/7, age 31.4+/-12.8 y, weight 68.9+/-13.2 kg, mean+/-SD) performed 3 sets of supine left LP to fatigue with 90 s of rest in 4 conditions: HL (%1-RM/cuff pressure: 80%/0); LL (20%/0); LBFR(sub DBP) (20%/1.3 x diastolic blood pressure, BP); LBFR(sub SBP) (20%/1.3 x supine systolic BP). The cuff remained inflated throughout the LBFR exercise sessions. Artery diameter, velocity time integral (VTI), and stroke volume (SV) were measured using Doppler ultrasound at rest and immediately after each set of exercise. Heart rate (HR) was monitored using a 3-lead ECG. BF was calculated as VTI x vessel cross-sectional area. CO was calculated as HR x SV. The data obtained after each set of exercise were averaged and used for analyses. Multi-level modeling was used to determine the effect of exercise condition on dependent variables. Statistical significance was set a priori at p LL (9.92+/-0.82 cm3) > LBFR(sub dBP)(6.47+/-0.79 cm3) > LBFR(sub SBP) (3.51+/-0.59 cm3). Blunted exercise induced increases occurred in HR, SV, and CO after LBFR compared to HL and LL. HR increased 45% after HL and LL and 28% after LBFR (p<0.05), but SV increased (p<0.05) only after HL. Consequently, the increase (p<0.05) in CO was greater in HL and LL (approximately 3 L/min) than in LBFR (approximately 1 L/min). CONCLUSION: BF during LBFR(sub SBP) was 1/3 of that observed in LL, which supports the hypothesis that local ischemia stimulates the LBFR hypertrophic response. As the cuff did not compress the artery, the ischemia may have occurred

  20. Non-Invasive Determination of Cardiac Output in Pre-Capillary Pulmonary Hypertension.

    Directory of Open Access Journals (Sweden)

    Frédéric Lador

    Full Text Available Cardiac output (CO is a major diagnostic and prognostic factor in pre-capillary pulmonary hypertension (PH. Reference methods for CO determination, like thermodilution (TD, require invasive procedures and allow only steady-state measurements. The Modelflow (MF method is an appealing technique for this purpose as it allows non-invasive and beat-by-beat determination of CO.We aimed to compare CO values obtained simultaneously from non-invasive pulse wave analysis by MF (COMF and by TD (COTD to determine its precision and accuracy in pre-capillary PH. The study was performed on 50 patients with pulmonary arterial hypertension (PAH or chronic thrombo-embolic PH (CTEPH. CO was determined at rest in all patients (n = 50 and during nitric oxide vasoreactivity test, fluid challenge or exercise (n = 48.Baseline COMF and COTD were 6.18 ± 1.95 and 5.46 ± 1.95 L·min-1, respectively. Accuracy and precision were 0.72 and 1.04 L·min-1, respectively. Limits of agreement (LoA ranged from -1.32 to 2.76 L·min-1. Percentage error (PE was ±35.7%. Overall sensitivity and specificity of COMF for directional change were 95.2% and 82.4%, (n = 48 and 93.3% and 100% for directional changes during exercise (n = 16, respectively. After application of a correction factor (1.17 ± 0.25, neither proportional nor fixed bias was found for subsequent CO determination (n = 48. Accuracy was -0.03 L·min-1 and precision 0.61 L·min-1. LoA ranged from -1.23 to 1.17 L·min-1 and PE was ±19.8%.After correction against a reference method, MF is precise and accurate enough to determine absolute values and beat-by-beat relative changes of CO in pre-capillary PH.

  1. Scalp congenital hemangioma with associated high-output cardiac failure in a premature infant: Case report and review of literature.

    Science.gov (United States)

    Shah, Sumedh S; Snelling, Brian M; Sur, Samir; Ramnath, Alexandra R; Bandstra, Emmalee S; Yavagal, Dileep R

    2017-02-01

    Introduction Scalp congenital hemangiomas (CHs) are rare vascular malformations among infants; they can be associated with an array of complications, including cardiac and cosmetic issues. Here, we report the endovascular treatment of a premature infant with a suspected large right parietal scalp hemangioma and associated high-output cardiac failure. Case description A two-day-old female premature infant (29 weeks gestational age; 1330 g birth weight) was referred by the neonatologists to our department for consultation and potential treatment of a large right parietal CH causing abrupt hypotension and high-output cardiac failure. Doppler ultrasound imaging at bedside revealed areas of arterial-venous shunting from the scalp and the presence of a superior sagittal sinus waveform, consistent with intracranial venous drainage. To alleviate cardiac dysfunction secondary to this lesion, trans-arterial embolization via n-butyl cyanoacrylate (nBCA) glue and deployment of detachable coils was performed via umbilical artery to occlude the right superficial temporal and occipital artery branches supplying the CH. Following treatment, the infant continued to require ventilator management, vasopressor support, and correction of coagulopathy, but by post-operative day two, her condition improved remarkably and the mass size began decreasing. The patient was discharged after a relatively uncomplicated subsequent 2½-month course in the neonatal intensive care unit. Conclusion Endovascular therapy proved effective and safe in treating cardiac failure associated with scalp CH, despite potential complications associated with neuro-interventional surgery in premature infants. Appropriate consideration in this patient population should be given to factors including blood loss, contrast use, radiation exposure, operative time, and possible intra-/post-operative complications.

  2. Validation of the use of foreign gas rebreathing method for non-invasive determination of cardiac output in heart disease patients

    Institute of Scientific and Technical Information of China (English)

    DONG Liang; WANG Jian-an; JIANG Chen-yang

    2005-01-01

    Objective: To compare a new device (Innocor) for non-invasive measurement of cardiac output (CO) by foreign gas rebreathing method with conventional techniques used in the measurements of cardiac function. Methods: Cardiac outputs measured by Innocor (CORB) were compared with CO obtained by echocardiography (COEC), Swan-Ganz thermodilution (COTD),and left ventricle radiography (COLVR) in 34 patients subjected to cardiac catheterization. Values obtained from the four methods were analyzed by linear regression and paired values were compared by the method of Bland and Altman in SPSS. Results: There was strong positive correlation (r=0.94) between Innocor cardiac output values and the corresponding values obtained by thermodilution and between COEC and COLVR values. Thermodilution appears to overestimate cardiac output when compared to the values obtained with Innocor by (0.66±0.22) L/min (P<0.0001). There was no correlation between data obtained by Innocor and the corresponding COEC and COLVR values. Conclusion: Innocor CORB is an easy, safe and well established method for non-invasive measurement of cardiac output with good prospects for clinical application in heart disease patients.

  3. Improved hepatic arterial fraction estimation using cardiac output correction of arterial input functions for liver DCE MRI

    Science.gov (United States)

    Chouhan, Manil D.; Bainbridge, Alan; Atkinson, David; Punwani, Shonit; Mookerjee, Rajeshwar P.; Lythgoe, Mark F.; Taylor, Stuart A.

    2017-02-01

    Liver dynamic contrast enhanced (DCE) MRI pharmacokinetic modelling could be useful in the assessment of diffuse liver disease and focal liver lesions, but is compromised by errors in arterial input function (AIF) sampling. In this study, we apply cardiac output correction to arterial input functions (AIFs) for liver DCE MRI and investigate the effect on dual-input single compartment hepatic perfusion parameter estimation and reproducibility. Thirteen healthy volunteers (28.7  ±  1.94 years, seven males) underwent liver DCE MRI and cardiac output measurement using aortic root phase contrast MRI (PCMRI), with reproducibility (n  =  9) measured at 7 d. Cardiac output AIF correction was undertaken by constraining the first pass AIF enhancement curve using the indicator-dilution principle. Hepatic perfusion parameters with and without cardiac output AIF correction were compared and 7 d reproducibility assessed. Differences between cardiac output corrected and uncorrected liver DCE MRI portal venous (PV) perfusion (p  =  0.066), total liver blood flow (TLBF) (p  =  0.101), hepatic arterial (HA) fraction (p  =  0.895), mean transit time (MTT) (p  =  0.646), distribution volume (DV) (p  =  0.890) were not significantly different. Seven day corrected HA fraction reproducibility was improved (mean difference 0.3%, Bland–Altman 95% limits-of-agreement (BA95%LoA)  ±27.9%, coefficient of variation (CoV) 61.4% versus 9.3%, ±35.5%, 81.7% respectively without correction). Seven day uncorrected PV perfusion was also improved (mean difference 9.3 ml min‑1/100 g, BA95%LoA  ±506.1 ml min‑1/100 g, CoV 64.1% versus 0.9 ml min‑1/100 g, ±562.8 ml min‑1/100 g, 65.1% respectively with correction) as was uncorrected TLBF (mean difference 43.8 ml min‑1/100 g, BA95%LoA  ±586.7 ml min‑1/ 100 g, CoV 58.3% versus 13.3 ml min‑1/100 g, ±661.5 ml min‑1/100 g, 60

  4. Noninvasive assessment of cardiac output from arterial pressure profiles during exercise.

    Science.gov (United States)

    Antonutto, G; Girardis, M; Tuniz, D; di Prampero, P E

    1995-01-01

    , MAPin, HR, PP, MAP are the above parameters at rest and during exercise, respectively. Also in this case, the coefficients f to 1 were determined by a computerized statistical method using Z* as the experimental reference. The values of Zcor so obtained allowed us to calculate SV from arterial pulse contour analysis as SVF = As.Z-1cor. The mean percentage error between the SVF obtained and the values simultaneously determined by PDE, was 10.0 (SD 8.7)%. It is concluded that the SV of the left ventricle, and hence cardiac output, can be determined during exercise from photoplethysmograph tracings with reasonable accuracy, provided that an initial estimate of SV at rest is made by means an independent high quality reference method.

  5. The thick left ventricular wall of the giraffe heart normalises wall tension, but limits stroke volume and cardiac output.

    Science.gov (United States)

    Smerup, Morten; Damkjær, Mads; Brøndum, Emil; Baandrup, Ulrik T; Kristiansen, Steen Buus; Nygaard, Hans; Funder, Jonas; Aalkjær, Christian; Sauer, Cathrine; Buchanan, Rasmus; Bertelsen, Mads Frost; Østergaard, Kristine; Grøndahl, Carsten; Candy, Geoffrey; Hasenkam, J Michael; Secher, Niels H; Bie, Peter; Wang, Tobias

    2016-02-01

    Giraffes--the tallest extant animals on Earth--are renowned for their high central arterial blood pressure, which is necessary to secure brain perfusion. Arterial pressure may exceed 300 mmHg and has historically been attributed to an exceptionally large heart. Recently, this has been refuted by several studies demonstrating that the mass of giraffe heart is similar to that of other mammals when expressed relative to body mass. It thus remains unexplained how the normal-sized giraffe heart generates such massive arterial pressures. We hypothesized that giraffe hearts have a small intraventricular cavity and a relatively thick ventricular wall, allowing for generation of high arterial pressures at normal left ventricular wall tension. In nine anaesthetized giraffes (495±38 kg), we determined in vivo ventricular dimensions using echocardiography along with intraventricular and aortic pressures to calculate left ventricular wall stress. Cardiac output was also determined by inert gas rebreathing to provide an additional and independent estimate of stroke volume. Echocardiography and inert gas-rebreathing yielded similar cardiac outputs of 16.1±2.5 and 16.4±1.4 l min(-1), respectively. End-diastolic and end-systolic volumes were 521±61 ml and 228±42 ml, respectively, yielding an ejection fraction of 56±4% and a stroke volume of 0.59 ml kg(-1). Left ventricular circumferential wall stress was 7.83±1.76 kPa. We conclude that, relative to body mass, a small left ventricular cavity and a low stroke volume characterizes the giraffe heart. The adaptations result in typical mammalian left ventricular wall tensions, but produce a lowered cardiac output.

  6. Low cardiac output as physiological phenomenon in hibernating, free-ranging Scandinavian brown bears (Ursus arctos) - an observational study

    DEFF Research Database (Denmark)

    Jørgensen, Peter Godsk; Arnemo, Jon; Swenson, Jon E

    2014-01-01

    hibernation in February 2013 and with medetomidine-zolazepam-tiletamine during active state in June 2013. We measured cardiac output noninvasively using estimates of hemodynamics obtained by pulsed wave Doppler echocardiography and 2D imaging. Comparisons were made using paired T-tests. RESULTS: During....... CONCLUSION: Free-ranging brown bears demonstrate hemodynamics comparable to humans during active state, whereas during hibernation, we documented extremely low-flow hemodynamics. Understanding these physiological changes in bears may help to gain insight into the mechanisms of cardiogenic shock and heart...

  7. Clinical review: Guyton--the role of mean circulatory filling pressure and right atrial pressure in controlling cardiac output.

    Science.gov (United States)

    Henderson, William R; Griesdale, Donald E G; Walley, Keith R; Sheel, A William

    2010-01-01

    Arthur Guyton's concepts of the determinative role of right heart filling in cardiac output continue to be controversial. This paper reviews his seminal experiments in detail and clarifies the often confusing concepts underpinning his model. One primary criticism of Guyton's model is that the parameters describing venous return had not been measured in a functioning cardiovascular system in humans. Thus, concerns have been expressed in regard to the ability of Guyton's simplistic model, with few parameters, to model the complex human circulation. Further concerns have been raised in regard to the artificial experimental preparations that Guyton used. Recently reported measurements in humans support Guyton's theoretical and animal work.

  8. Combined use of phenoxybenzamine and dopamine for low cardiac output syndrome in children at withdrawal from cardiopulmonary bypass.

    Science.gov (United States)

    Kawamura, M; Minamikawa, O; Yokochi, H; Maki, S; Yasuda, T; Mizukawa, Y

    1980-04-01

    The combined use of phenoxybenzamine and dopamine was applied in infants and children when it was difficult to come off cardiopulmonary bypass for low cardiac output. The rationale of this method is to prevent the alpha-adrenergic action of dopamine by phenoxybenzamine and to encourage the beta-adrenergic and direct specific action of dopamine. Dopamine was used in dosage of 10 to 30 micrograms/kg per min after the additional administration of a half of the initial dosage of phenoxybenzamine; this was infused by drip always in a dosage of 0.5 to 1.0 mg/kg during the first half of cardiopulmonary bypass. It was possible to come off cardiopulmonary bypass with a stable haemodynamic state (mean arterial pressure more than 60 mmHg and total peripheral vascular resistance less than 2000 bynes s cm-5) and a good urinary output.

  9. Measurements of cardiac output obtained with transesophageal echocardiography and pulmonary artery thermodilution are not interchangeable

    DEFF Research Database (Denmark)

    Møller-Sørensen, H; Graeser, K; Hansen, K L

    2014-01-01

    BACKGROUND: Echocardiography is increasingly becoming an integrated tool for circulatory evaluation in the intensive care unit and the operating room. Therefore, it is imperative to know the reproducibility of measurements obtained by echocardiography. In this study, a comparison of cardiac outpu...

  10. Pulmonary Artery Catheter (PAC Accuracy and Efficacy Compared with Flow Probe and Transcutaneous Doppler (USCOM: An Ovine Cardiac Output Validation

    Directory of Open Access Journals (Sweden)

    Robert A. Phillips

    2012-01-01

    Full Text Available Background. The pulmonary artery catheter (PAC is an accepted clinical method of measuring cardiac output (CO despite no prior validation. The ultrasonic cardiac output monitor (USCOM is a noninvasive alternative to PAC using Doppler ultrasound (CW. We compared PAC and USCOM CO measurements against a gold standard, the aortic flow probe (FP, in sheep at varying outputs. Methods. Ten conscious sheep, with implanted FPs, had measurements of CO by FP, USCOM, and PAC, at rest and during intervention with inotropes and vasopressors. Results. CO measurements by FP, PAC, and USCOM were 4.0±1.2 L/min, 4.8±1.5 L/min, and 4.0±1.4 L/min, respectively, (=280, range 1.9 L/min to 11.7 L/min. Percentage bias and precision between FP and PAC, and FP and USCOM was −17 and 47%, and 1 and 36%, respectively. PAC under-measured Dobutamine-induced CO changes by 20% (relative 66% compared with FP, while USCOM measures varied from FP by 3% (relative 10%. PAC reliably detected −30% but not +40% CO changes, as measured by receiver operating characteristic area under the curve (AUC, while USCOM reliably detected ±5% changes in CO (AUC>0.70. Conclusions. PAC demonstrated poor accuracy and sensitivity as a measure of CO. USCOM provided equivalent measurements to FP across a sixfold range of outputs, reliably detecting ±5% changes.

  11. Reduced peripheral arterial blood flow with preserved cardiac output during submaximal bicycle exercise in elderly heart failure

    Directory of Open Access Journals (Sweden)

    Leng Xiaoyan

    2009-11-01

    Full Text Available Abstract Background Older heart failure (HF patients exhibit exercise intolerance during activities of daily living. We hypothesized that reduced lower extremity blood flow (LBF due to reduced forward cardiac output would contribute to submaximal exercise intolerance in older HF patients. Methods and Results Twelve HF patients both with preserved and reduced left ventricular ejection fraction (LVEF (aged 68 ± 10 years without large (aorta or medium sized (iliac or femoral artery vessel atherosclerosis, and 13 age and gender matched healthy volunteers underwent a sophisticated battery of assessments including a peak exercise oxygen consumption (peak VO2, b physical function, c cardiovascular magnetic resonance (CMR submaximal exercise measures of aortic and femoral arterial blood flow, and d determination of thigh muscle area. Peak VO2 was reduced in HF subjects (14 ± 3 ml/kg/min compared to healthy elderly subjects (20 ± 6 ml/kg/min (p = 0.01. Four-meter walk speed was 1.35 ± 0.24 m/sec in healthy elderly verses 0.98 ± 0.15 m/sec in HF subjects (p p ≤ 0.03. Conclusion During CMR submaximal bike exercise in the elderly with heart failure, mechanisms other than low cardiac output are responsible for reduced lower extremity blood flow.

  12. Application of intraoperative arterial pressure-based cardiac output monitoring for patients undergoing coronary artery bypass grafting surgery

    Institute of Scientific and Technical Information of China (English)

    LU Jia-kai; ZHU Chen; JING He; WANG Yi-jun; QING En-ming

    2012-01-01

    Background For patients undergoing off-pump coronary artery bypass grafting (OPCABG),it is important to establish a hemodynamic monitoring system to obtain powerful parameters for better intraoperative treatment.This study aimed to observe the clinical feasibility of artedal pressure-based cardiac output (APCO) for cardiac output (CO) monitoring and to evaluate the correlation between APCO and pulmonary artery catheter (PAC) for CO measurement for patients undergoing OPCABG intraoperatively.Methods Fifty patients of Amedcan Society of Anaesthesiologists (ASA) classification Ⅱ-Ⅲ,undergoing elective OPCABG at Beijing Anzhen Hospital were randomly enrolled into this study.All patients were assigned to CO monitoring by PAC and APCO simultaneously.Patients with pacemaker,severe valvular heart disease,left ventdcular ejection fraction (EF) <40%,cardiac arrhythmias,peripheral vascular disease,application of intra-aortic balloon pump (IABP) and emergent diversion to cardiac pulmonary bypass were excluded.The radial artery wavaform was analyzed to estimate the stroke volume (SV) and heart rate (HR) continuously.CO was calculated as SV x HR; other derived parameters were cardiac index (CI),stroke volume index (SVI),systemic vascular resistance (SVR),and systemic vascular resistance index (SVRI).PAC was placed via right internal jugular vein and the correct position was confirmed by PAC waveforms.Continuous cardiac output (CCO),CI and other hemodynamic parameters were monitored at following 5 time points:immediate after anesthesia induction (baseline value),anastomosis of left intemal mammary artery to left anterior descending artery (LAD),anastomosis of left circumflex (LCX),anastomosis of posterior descending artery (PDA) and immediate after sternal closure.Results In the 50 patients,preoperative echocardiography measured left ventricular EF was (52.8±11.5)%,and 35 patients (70%) showed regional wall motion abnormalities.The correlation coefficient of CO

  13. A review of intraoperative goal-directed therapy using arterial waveform analysis for assessment of cardiac output.

    Science.gov (United States)

    Mehta, Neil; Fernandez-Bustamante, Ana; Seres, Tamas

    2014-01-01

    Increasing evidence shows that goal-directed hemodynamic management can improve outcomes in surgical and intensive care settings. Arterial waveform analysis is one of the different techniques used for guiding goal-directed therapy. Multiple proprietary systems have developed algorithms for obtaining cardiac output from an arterial waveform, including the FloTrac, LiDCO, and PiCCO systems. These systems vary in terms of how they analyze the arterial pressure waveform as well as their requirements for invasive line placement and calibration. Although small-scale clinical trials using these monitors show promising data, large-scale multicenter trials are still needed to better determine how intraoperative goal-directed therapy with arterial waveform analysis can improve patient outcomes. This review provides a comparative analysis of the different arterial waveform monitors for intraoperative goal-directed therapy.

  14. A Review of Intraoperative Goal-Directed Therapy Using Arterial Waveform Analysis for Assessment of Cardiac Output

    Directory of Open Access Journals (Sweden)

    Neil Mehta

    2014-01-01

    Full Text Available Increasing evidence shows that goal-directed hemodynamic management can improve outcomes in surgical and intensive care settings. Arterial waveform analysis is one of the different techniques used for guiding goal-directed therapy. Multiple proprietary systems have developed algorithms for obtaining cardiac output from an arterial waveform, including the FloTrac, LiDCO, and PiCCO systems. These systems vary in terms of how they analyze the arterial pressure waveform as well as their requirements for invasive line placement and calibration. Although small-scale clinical trials using these monitors show promising data, large-scale multicenter trials are still needed to better determine how intraoperative goal-directed therapy with arterial waveform analysis can improve patient outcomes. This review provides a comparative analysis of the different arterial waveform monitors for intraoperative goal-directed therapy.

  15. Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision.

    Science.gov (United States)

    Peyton, Philip J; Chong, Simon W

    2010-11-01

    When assessing the accuracy and precision of a new technique for cardiac output measurement, the commonly quoted criterion for acceptability of agreement with a reference standard is that the percentage error (95% limits of agreement/mean cardiac output) should be 30% or less. We reviewed published data on four different minimally invasive methods adapted for use during surgery and critical care: pulse contour techniques, esophageal Doppler, partial carbon dioxide rebreathing, and transthoracic bioimpedance, to assess their bias, precision, and percentage error in agreement with thermodilution. An English language literature search identified published papers since 2000 which examined the agreement in adult patients between bolus thermodilution and each method. For each method a meta-analysis was done using studies in which the first measurement point for each patient could be identified, to obtain a pooled mean bias, precision, and percentage error weighted according to the number of measurements in each study. Forty-seven studies were identified as suitable for inclusion: N studies, n measurements: mean weighted bias [precision, percentage error] were: pulse contour N = 24, n = 714: -0.00 l/min [1.22 l/min, 41.3%]; esophageal Doppler N = 2, n = 57: -0.77 l/min [1.07 l/min, 42.1%]; partial carbon dioxide rebreathing N = 8, n = 167: -0.05 l/min [1.12 l/min, 44.5%]; transthoracic bioimpedance N = 13, n = 435: -0.10 l/min [1.14 l/min, 42.9%]. None of the four methods has achieved agreement with bolus thermodilution which meets the expected 30% limits. The relevance in clinical practice of these arbitrary limits should be reassessed.

  16. Cardiac output by Doppler echocardiography in the premature baboon: comparison with radiolabeled microspheres.

    Science.gov (United States)

    Kinsella, J P; Morrow, W R; Gerstmann, D R; Taylor, A F; deLemos, R A

    1991-04-01

    Pulsed-Doppler echocardiography (PDE) is a useful noninvasive method for determining left ventricular output (LVO). However, despite increasingly widespread use in neonatal intensive care units, validation studies in prematures with cardiopulmonary disease are lacking. The purpose of this study was to compare radiolabeled microsphere (RLM) and PDE measurements of LVO, using the critically ill premature baboon as a model of the human neonate. Twenty-two paired RLM and PDE measurements of LVO were obtained in 14 animals between 3 and 24 h of age. Average PDE LVO was 152 ml/min/kg (range, 40-258 ml/min/kg) compared to 158 ml/min/kg (range, 67-278 ml/min/kg) measured by RLM. Linear regression analysis of the paired measurements showed good correlation with a slope near unity (gamma = 0.94x + 4.20, r = 0.91, SEE = 25.7 ml). We conclude that PDE determinations of LVO compare well with those measured by RLM in the premature baboon. PDE appears to provide a valid estimate of LVO and should be useful in human prematures with cardiopulmonary distress.

  17. Calibrated versus uncalibrated arterial pressure waveform analysis in monitoring cardiac output with transpulmonary thermodilution in patients with severe sepsis and septic shock: an observational study

    NARCIS (Netherlands)

    Slagt, C.; Helmi, M.; Malagon, I.; Groeneveld, A.B.

    2015-01-01

    BACKGROUND: Cardiac output (CO) measurement is often required in critically ill patients. The performances of newer, less invasive techniques require evaluation in patients with severe sepsis and septic shock. OBJECTIVES: To compare calibrated arterial pressure waveform analysis-derived CO (COap, Vo

  18. Effects of water immersion on cardiac output of lean and fat male subjects at rest and during exercise.

    Science.gov (United States)

    Haffor, A S; Mohler, J G; Harrison, A C

    1991-02-01

    To investigate the combined effect of water immersion (WI) and lean body mass on cardiac output (Q), 12 healthy young men, 6 lean (fat less than 9%) and 6 fat (fat greater than 18%), were studied at rest and during steady state exercise approximating 30-40% Vo2 max under three experimental conditions. There were on land at 24 degrees C (LND), and immersed in water at 33-34 degrees C to hip level (HIP), and to the xiphoid (XIP). Metabolic measures were determined during 30-s periods from the average breath measurements. Mixed venous PCO2 (PVCO2) was estimated using rebreathing equilibration technique. Cardiac output was calculated by the indirect Fick's principle. In the lean individuals the average Q rose from a resting value of 5.43 +/- 0.43 (LND) to an exercise value of 7.25 +/- 0.40 L/min (XIP), and from resting value of 5.62 +/- 0.40 to an exercise 6.47 +/- 0.5 L/min in the fat individuals. During exercise, the associated increase in Q with increasing WI was significantly (p less than 0.05) higher compared with the land experiments. Inspection of the mean profile corresponding to this increase indicated that an increase in the level of immersion results in a significant (p less than 0.05) increase in the average Q for the lean group. For the fat group, the average Q was significantly (p less than 0.05) larger only at XIP level. At rest, heart rate dropped from 67 +/- 3.36 (LND) to 60 +/- 4.13 (XIP), and from 79 +/- 3.73 to 73 +/- 4.10 BPM for the lean and fat group, respectively. MANOVA analysis showed a significant (p less than 0.05) interaction between WI and group membership, indicating that the effect of WI is significantly different between the two groups. These data indicate that the change in central blood volume with WI depends, in part, on the lean mass of the body.

  19. Fetal cardiac ventricular volume, cardiac output, and ejection fraction determined with four-dimensional ultrasound using Spatio-Temporal Image Correlation (STIC) and Virtual Organ Computed-aided AnaLysis (VOCAL™)

    Science.gov (United States)

    Hamill, Neil; Yeo, Lami; Romero, Roberto; Hassan, Sonia S.; Myers, Stephen A.; Mittal, Pooja; Kusanovic, Juan Pedro; Balasubramaniam, Mamtha; Chaiworapongsa, Tinnakorn; Vaisbuch, Edi; Espinoza, Jimmy; Gotsch, Francesca; Goncalves, Luis F.; Lee, Wesley

    2011-01-01

    Objective To quantify fetal cardiovascular parameters with Spatio-Temporal Image Correlation (STIC) and Virtual Organ Computed-aided AnaLysis (VOCAL™) utilizing the sub-feature: “Contour Finder: Trace”. Study Design A cross-sectional study was designed consisting of patients with normal pregnancies between 19 and 40 weeks of gestation. After STIC datasets were acquired, analysis was performed offline (4DView) and the following cardiovascular parameters were evaluated: ventricular volume in end systole and end diastole, stroke volume, cardiac output, and ejection fraction. To account for fetal size, cardiac output was also expressed as a function of head circumference, abdominal circumference, or femoral diaphysis length. Regression models were fitted for each cardiovascular parameter to assess the effect of gestational age and paired comparisons were made between the left and right ventricles. Results 1) Two hundred and seventeen patients were retrospectively identified, of whom 184 had adequate STIC datasets (85% acceptance); 2) ventricular volume, stroke volume, cardiac output, and adjusted cardiac output increased with gestational age; whereas, the ejection fraction decreased as gestation advanced; 3) the right ventricle was larger than the left in both systole (Right: 0.50 ml, IQR: 0.2 – 0.9; vs. Left: 0.27 ml, IQR: 0.1 – 0.5; p<0.001) and diastole (Right: 1.20 ml, IQR: 0.7 – 2.2; vs. Left: 1.03 ml, IQR: 0.5 – 1.7; p<0.001); 4) there were no differences between the left and right ventricle with respect to stroke volume, cardiac output, or adjusted cardiac output; and 5) the left ventricular ejection fraction was greater than the right (Left: 72.2%, IQR: 64 – 78; vs. Right: 62.4%, IQR: 56 – 69; p<0.001). Conclusion Fetal echocardiography, utilizing STIC and VOCAL™ with the sub-feature: “Contour Finder: Trace”, allows assessment of fetal cardiovascular parameters. Normal fetal cardiovascular physiology is characterized by ventricular

  20. Plasma volume expansion does not increase maximal cardiac output or VO2 max in lowlanders acclimatized to altitude.

    Science.gov (United States)

    Calbet, José A L; Rådegran, Göran; Boushel, Robert; Søndergaard, Hans; Saltin, Bengt; Wagner, Peter D

    2004-09-01

    With altitude acclimatization, blood hemoglobin concentration increases while plasma volume (PV) and maximal cardiac output (Qmax) decrease. This investigation aimed to determine whether reduction of Qmax at altitude is due to low circulating blood volume (BV). Eight Danish lowlanders (3 females, 5 males: age 24.0 +/- 0.6 yr; mean +/- SE) performed submaximal and maximal exercise on a cycle ergometer after 9 wk at 5,260 m altitude (Mt. Chacaltaya, Bolivia). This was done first with BV resulting from acclimatization (BV = 5.40 +/- 0.39 liters) and again 2-4 days later, 1 h after PV expansion with 1 liter of 6% dextran 70 (BV = 6.32 +/- 0.34 liters). PV expansion had no effect on Qmax, maximal O2 consumption (VO2), and exercise capacity. Despite maximal systemic O2 transport being reduced 19% due to hemodilution after PV expansion, whole body VO2 was maintained by greater systemic O2 extraction (P VO2 during exercise regardless of PV. Pulmonary ventilation, gas exchange, and acid-base balance were essentially unaffected by PV expansion. Sea level Qmax and exercise capacity were restored with hyperoxia at altitude independently of BV. Low BV is not a primary cause for reduction of Qmax at altitude when acclimatized. Furthermore, hemodilution caused by PV expansion at altitude is compensated for by increased systemic O2 extraction with similar peak muscular O2 delivery, such that maximal exercise capacity is unaffected.

  1. Cardiac output method comparison studies: the relation of the precision of agreement and the precision of method.

    Science.gov (United States)

    Hapfelmeier, Alexander; Cecconi, Maurizio; Saugel, Bernd

    2016-04-01

    Cardiac output (CO) plays a crucial role in the hemodynamic management of critically ill patients treated in the intensive care unit and in surgical patients undergoing major surgery. In the field of cardiovascular dynamics, innovative techniques for CO determination are increasingly available. Therefore, the number of studies comparing these techniques with a reference, such as pulmonary artery thermodilution, is rapidly growing. There are mainly two outcomes of such method comparison studies: (1) the accuracy of agreement and (2) the precision of agreement. The precision of agreement depends on the precision of each method, i.e., the precision that the studied and the reference technique are able to achieve. We call this "precision of method". A decomposition of variance shows that method agreement does not only depend on the precision of method but also on another important source of variability, i.e., the method's general variability about the true values. Ignorance of that fact leads to falsified conclusions about the precision of method of the studied technique. In CO studies, serial measurements are frequently confused with repeated measurements. But as the actual CO of a subject changes from assessment to assessment, there is no real repetition of a measurement. This situation equals a scenario in which single measurements are given for multiple true values per subject. In such a case it is not possible to assess the precision of method.

  2. Diesel Exhaust Inhalation Increases Cardiac Output, Bradyarrhythmias, and Parasympathetic Tone in Aged Heart Failure-Prone Rats

    Science.gov (United States)

    Acute air pollutant inhalation is linked to adverse cardiac events and death, and hospitalizations for heart failure. Diesel exhaust (DE) is a major air pollutant suspected to exacerbate preexisting cardiac conditions, in part, through autonomic and electrophysiologic disturbance...

  3. Cardiac output monitoring

    NARCIS (Netherlands)

    de Waal, Eric. E. C.; Wappler, Frank; Buhre, Wolfgang F.

    2009-01-01

    Purpose of review The primary goal of hemodynamic therapy is the prevention of inadequate tissue perfusion and inadequate oxygenation. Advanced cardiovascular monitoring is a prerequisite to optimize hemodynamic treatment in critically ill patients prone to cardiocirculatory failure. The most ideal

  4. Accuracy and precision of minimally-invasive cardiac output monitoring in children: a systematic review and meta-analysis.

    Science.gov (United States)

    Suehiro, Koichi; Joosten, Alexandre; Murphy, Linda Suk-Ling; Desebbe, Olivier; Alexander, Brenton; Kim, Sang-Hyun; Cannesson, Maxime

    2016-10-01

    Several minimally-invasive technologies are available for cardiac output (CO) measurement in children, but the accuracy and precision of these devices have not yet been evaluated in a systematic review and meta-analysis. We conducted a comprehensive search of the medical literature in PubMed, Cochrane Library of Clinical Trials, Scopus, and Web of Science from its inception to June 2014 assessing the accuracy and precision of all minimally-invasive CO monitoring systems used in children when compared with CO monitoring reference methods. Pooled mean bias, standard deviation, and mean percentage error of included studies were calculated using a random-effects model. The inter-study heterogeneity was also assessed using an I(2) statistic. A total of 20 studies (624 patients) were included. The overall random-effects pooled bias, and mean percentage error were 0.13 ± 0.44 l min(-1) and 29.1 %, respectively. Significant inter-study heterogeneity was detected (P error (23.6 %). Significant residual heterogeneity remained after conducting sensitivity and subgroup analyses based on the various study characteristics. By meta-regression analysis, we found no independent effects of study characteristics on weighted mean difference between reference and tested methods. Although the pooled bias was small, the mean pooled percentage error was in the gray zone of clinical applicability. In the sub-group analysis, electrical cardiometry was the device that provided the most accurate measurement. However, a high heterogeneity between studies was found, likely due to a wide range of study characteristics.

  5. Early predictors of acute kidney injury in patients with cirrhosis and bacterial infection: urinary neutrophil gelatinase-associated lipocalin and cardiac output as reliable tools

    Science.gov (United States)

    Ximenes, Rafael O.; Farias, Alberto Q.; Helou, Claudia M.B.

    2015-01-01

    Background Hemodynamic abnormalities and acute kidney injury (AKI) are often present in infected cirrhotic patients. Hence, an early diagnosis of AKI is necessary, which might require the validation of new predictors as the determinations of urinary neutrophil gelatinase-associated lipocalin (uNGAL) and cardiac output. Methods We evaluated 18 infected cirrhotic patients subdivided into two groups at admission (0 hours). In Group I, we collected urine samples at 0 hours, 6 hours, 24 hours, and 48 hours for uNGAL and fractional excretion of sodium determinations. In Group II, we measured cardiac output using echocardiography. Results The age of patients was 55.0±1.9 years, and 11 patients were males. The Model for End-Stage Liver Disease score was 21±1, whereas the Child–Pugh score was C in 11 patients and B in 7 patients. Both patients in Group I and Group II showed similar baseline characteristics. In Group I, we diagnosed AKI in 5 of 9 patients, and the mean time to this diagnosis by measuring serum creatinine was 5.4 days. Patients with AKI showed higher uNGAL levels than those without AKI from 6 hours to 48 hours. The best accuracy using the cutoff values of 68 ng uNGAL/mg creatinine was achieved at 48 hours when we distinguished patients with and without AKI in all cases. In Group II, we diagnosed AKI in 4 of 9 patients, and cardiac output was significantly higher in patients who developed AKI at 0 hours. Conclusion Both uNGAL and cardiac output determinations allow the prediction of AKI in infected cirrhotic patients earlier than increments in serum creatinine. PMID:26484038

  6. Importance of re-calibration time on pulse contour analysis agreement with thermodilution measurements of cardiac output: a retrospective analysis of intensive care unit patients.

    Science.gov (United States)

    Scully, Christopher G; Gomatam, Shanti; Forrest, Shawn; Strauss, David G

    2016-10-01

    We assessed the effect of re-calibration time on cardiac output estimation and trending performance in a retrospective analysis of an intensive care unit patient population using error grid analyses. Paired thermodilution and arterial blood pressure waveform measurements (N = 2141) from 222 patient records were extracted from the Multiparameter Intelligent Monitoring in Intensive Care II database. Pulse contour analysis was performed by implementing a previously reported algorithm at calibration times of 1, 2, 8 and 24 h. Cardiac output estimation agreement was assessed using Bland-Altman and error grid analyses. Trending was assessed by concordance and a 4-Quadrant error grid analysis. Error between pulse contour and thermodilution increased with longer calibration times. Limits of agreement were -1.85 to 1.66 L/min for 1 h maximum calibration time compared to -2.70 to 2.41 L/min for 24 h. Error grid analysis resulted in 74.2 % of points bounded by 20 % error limits of thermodilution measurements for 1 h calibration time compared to 65 % for 24 h. 4-Quadrant error grid analysis showed analysis method and thermodilution showed poor agreement to monitor changes in cardiac output.

  7. Differences of cardiac output measurements by open-circuit acetylene uptake in pulmonary arterial hypertension and chronic thromboembolic pulmonary hypertension: a cohort study

    Directory of Open Access Journals (Sweden)

    Schwaiblmair Martin

    2012-03-01

    Full Text Available Abstract Background As differences in gas exchange between pulmonary arterial hypertension (PAH and chronic thromboembolic pulmonary hypertension (CTEPH have been demonstrated, we asked if cardiac output measurements determined by acetylene (C2H2 uptake significantly differed in these diseases when compared to the thermodilution technique. Method Single-breath open-circuit C2H2 uptake, thermodilution, and cardiopulmonary exercise testing were performed in 72 PAH and 32 CTEPH patients. Results In PAH patients the results for cardiac output obtained by the two methods showed an acceptable agreement with a mean difference of -0.16 L/min (95% CI -2.64 to 2.32 L/min. In contrast, the agreement was poorer in the CTEPH group with the difference being -0.56 L/min (95% CI -4.96 to 3.84 L/min. Functional dead space ventilation (44.5 ± 1.6 vs. 32.2 ± 1.4%, p 2 gradient (9.9 ± 0.8 vs. 4.1 ± 0.5 mmHg, p Conclusion Cardiac output evaluation by the C2H2 technique should be interpreted with caution in CTEPH, as ventilation to perfusion mismatching might be more relevant than in PAH.

  8. Comparison of transthoracic electrical bioimpedance cardiac output measurement with thermodilution method in post coronary artery bypass graft patients.

    Science.gov (United States)

    Sharma, Vikas; Singh, Ajmer; Kansara, Bhuvnesh; Karlekar, Anil

    2011-01-01

    Transthoracic electrical bioimpedance (TEB) has been proposed as a non-invasive, continuous, and cost-effective method of cardiac output (CO) measurement. In this prospective, non-randomized, clinical study, we measured CO with NICOMON (Larsen and Toubro Ltd., Mysore, India) and compared it with thermodilution (TD) method in patients after off-pump coronary artery bypass (OPCAB) graft surgery. We also evaluated the effect of ventilation (mechanical and spontaneous) on the measurement of CO by the two methods. Forty-six post-OPCAB patients were studied at five predefined time points during controlled ventilation and at five time points when breathing spontaneously. A total of 230 data pairs of CO were obtained. During controlled ventilation, TD CO values ranged from 2.29 to 6.74 L/min (mean 4.45 ± 0.85 L/min), while TEB CO values ranged from 1.70 to 6.90 L/min (mean 4.43 ± 0.94 L/min). The average correlation (r) was 0.548 (P = 0.0002), accompanied by a bias of 0.015 L/min and precision of 0.859 L/min. In spontaneously breathing patients, TD CO values ranged from 2.66 to 6.92 L/min (mean 4.66 ± 0.76 L/min), while TEB CO values ranged from 3.08 to 6.90 L/min (mean 4.72 ± 0.82 L/min). Their average correlation was relatively poor (r = 0.469, P= 0.002), accompanied by a bias of -0.059 L/min and precision of 0.818 L/min. The overall percent errors between TD CO and TEB CO were 19.3% (during controlled ventilation) and 17.4% (during spontaneous breathing), respectively. To conclude, a fair correlation was found between TD CO and TEB CO measurements among post-OPCAB patients during controlled ventilation. However, the correlation was weak in spontaneously breathing patients.

  9. Comparison of transthoracic electrical bioimpedance cardiac output measurement with thermodilution method in post coronary artery bypass graft patients

    Directory of Open Access Journals (Sweden)

    Sharma Vikas

    2011-01-01

    Full Text Available Transthoracic electrical bioimpedance (TEB has been proposed as a non-invasive, continuous, and cost-effective method of cardiac output (CO measurement. In this prospective, non-randomized, clinical study, we measured CO with NICOMON (Larsen and Toubro Ltd., Mysore, India and compared it with thermodilution (TD method in patients after off-pump coronary artery bypass (OPCAB graft surgery. We also evaluated the effect of ventilation (mechanical and spontaneous on the measurement of CO by the two methods. Forty-six post-OPCAB patients were studied at five predefined time points during controlled ventilation and at five time points when breathing spontaneously. A total of 230 data pairs of CO were obtained. During controlled ventilation, TD CO values ranged from 2.29 to 6.74 L/min (mean 4.45 ± 0.85 L/min, while TEB CO values ranged from 1.70 to 6.90 L/min (mean 4.43 ± 0.94 L/min. The average correlation (r was 0.548 (P = 0.0002, accompanied by a bias of 0.015 L/min and precision of 0.859 L/min. In spontaneously breathing patients, TD CO values ranged from 2.66 to 6.92 L/min (mean 4.66 ± 0.76 L/min, while TEB CO values ranged from 3.08 to 6.90 L/min (mean 4.72 ± 0.82 L/min. Their average correlation was relatively poor (r = 0.469, P= 0.002, accompanied by a bias of −0.059 L/min and precision of 0.818 L/min. The overall percent errors between TD CO and TEB CO were 19.3% (during controlled ventilation and 17.4% (during spontaneous breathing, respectively. To conclude, a fair correlation was found between TD CO and TEB CO measurements among post-OPCAB patients during controlled ventilation. However, the correlation was weak in spontaneously breathing patients.

  10. Cardiac output measured by electrical velocimetry in the CT suite correlates with coronary artery enhancement: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Flinck, Marianne; Graden, Aasa; Milde, Helen; Flinck, Agneta; Hellstroem, Mikael (Dept. of Radiology, Sahlgrenska Univ. Hospital and Sahlgrenska Academy at Goetenborg Univ., Goeteborg (Sweden)); Bjoerk, Jonas (Competence Centre for Clinical Research, Lund Univ. Hospital, Lund (Sweden)); Nyman, Ulf (Dept. of Radiology, Lasarettet Trelleborg, Univ. of Lund, Trelleborg (Sweden)), e-mail: ulf.nyman@skane.se

    2010-10-15

    Background: Cardiac output (CO) is inversely related to vascular contrast medium (CM) enhancement during computed tomography (CT). Impedance cardiography with a new technique, electrical velocimetry (EV), may create opportunities to measure CO pre-examination for adaptation of CM injection parameters. Purpose: To relate COEV measured by radiology staff to aortic attenuation as a measure of coronary artery attenuation during CT coronary angiography (CTCA), and to formulate a tentative statistical model to adapt CM injection parameters to CO. Material and Methods: COEV was measured immediately before 100 kVp CTCA (64-multirow detector) in 27 patients with presumed coronary artery disease. For CTCA, 260 mg I/kg (maximum dosage weight: 80/90 kg for women/men) was injected intravenously during 12 s. Simple linear regression analysis was performed to explore the correlation between aortic attenuation (Hounsfield units, HU) and body weight, the influence of COEV on aortic attenuation adjusted to injected CM dose rate (HU per mg I/kg/s), and to establish a tentative formula on how to adapt CM injection parameters to COEV and desired aortic attenuation. Results: The correlation between aortic attenuation and body weight was weak and non-significant (r=-0.14 after outlier exclusion). A significant negative correlation (r=-0.63) was found between aortic attenuation adjusted to injected CM dose rate (HU per mg I/kg/s) and COEV. The resulting formula, CM dose rate=COEVx(aortic attenuation-240)/55, made it possible to calculate CM volumes and injection rates at various COs and, for example, the present mean aortic attenuation (438 HU), injection time (12 s), CM concentration (320 mg I/ml), and a certain body weight. Conclusion: EV makes it possible to measure CO in the CT suite before vascular examinations. Hence, CM doses may be decreased in low CO states to reduce the risk of CM-induced nephropathy without jeopardizing diagnostic quality and may be increased in high CO states

  11. Derivation of cardiac output and alveolar ventilation rate based on energy expenditure measurements in healthy males and females.

    Science.gov (United States)

    Brochu, Pierre; Brodeur, Jules; Krishnan, Kannan

    2012-08-01

    Physiologically based pharmacokinetic modeling and occupational exposure assessment studies often use minute ventilation rates (VE), alveolar ventilation rates (VA) and cardiac outputs (Q) that are not reflective of the physiological variations encountered during the aggregate daytime activities of individuals from childhood to adulthood. These variations of VE, VA and Q values were determined for healthy normal-weight individuals aged 5-96 years by using two types of published individual data that were measured in the same subjects (n = 902), namely indirect calorimetry measurements and the disappearance rates of oral doses of deuterium (²H) and heavy-oxygen (¹⁸O) in urine monitored by gas-isotope-ratio mass spectrometry. Arteriovenous oxygen content differences (0.051-0.082 ml of O₂ consumed ml⁻¹ of blood) and ratios of the physiological dead space to the tidal volume (0.232-0.419) were determined for oxygen consumption rates (0.157-0.806 l min⁻¹) required by minute energy expenditures ranging from 0.76 to 3.91 kcal min⁻¹. Generally higher values for the 2.5th up to the 99th percentile for VE (0.132-0.774 l kg⁻¹ min⁻¹, 4.42-21.69 l m⁻² min⁻¹), VA (0.093-0.553 l kg⁻¹ min⁻¹, 3.09-15.53 l m⁻² min⁻¹), Q (0.065-0.330 l kg⁻¹ min⁻¹, 2.17 to 9.46 l m⁻² min⁻¹) and ventilation-perfusion ratios (1.12-2.16) were found in children and teenagers aged 5-<16.5 years compared with older individuals. The distributions of cardiopulmonary parameters developed in this study should be useful in facilitating a scientifically sound characterization of the inter-individual differences in the uptake and health risks of lipophilic air pollutants, particularly as they relate to younger children.

  12. Impact of changes in systemic vascular resistance on a novel non-invasive continuous cardiac output measurement system based on pulse wave transit time: a report of two cases.

    Science.gov (United States)

    Ishihara, Hironori; Tsutsui, Masato

    2014-08-01

    The inaccuracy of arterial waveform analysis for measuring continuos cardiac output (CCO) associated with changes in systemic vascular resistance (SVR) has been well documented. A new non-invasive continuous cardiac output monitoring system (esCCO) mainly utilizing pulse wave transit time (PWTT) in place of arterial waveform analysis has been developed. However, the trending ability of esCCO to measure cardiac output during changes in SVR remains unclear. After a previous multicenter study on esCCO measurement, we retrospectively identified two cases in which apparent changes in SVR developed in a short period during data collection. In each case, the trending ability of esCCO to measure cardiac output and time component of PWTT were analyzed. Recorded data suggest that the time component of PWTT may have a significant impact on the accuracy of estimating stroke volume during changes in SVR. However, further prospective clinical studies are required to test this hypothesis.

  13. Substrate stiffness-regulated matrix metalloproteinase output in myocardial cells and cardiac fibroblasts: implications for myocardial fibrosis.

    Science.gov (United States)

    Xie, Jing; Zhang, Quanyou; Zhu, Ting; Zhang, Yanyan; Liu, Bailin; Xu, Jianwen; Zhao, Hucheng

    2014-06-01

    Cardiac fibrosis, an important pathological feature of structural remodeling, contributes to ventricular stiffness, diastolic dysfunction, arrhythmia and may even lead to sudden death. Matrix stiffness, one of the many mechanical factors acting on cells, is increasingly appreciated as an important mediator of myocardial cell behavior. Polydimethylsiloxane (PDMS) substrates were fabricated with different stiffnesses to mimic physiological and pathological heart tissues, and the way in which the elastic modulus of the substrate regulated matrix-degrading gelatinases in myocardial cells and cardiac fibroblasts was explored. Initially, an increase in cell spreading area was observed, concomitant with the increase in PDMS stiffness in both cells. Later, it was demonstrated that the MMP-2 gene expression and protein activity in myocardial cells and cardiac fibroblasts can be enhanced with an increase in PDMS substrate stiffness and, moreover, such gene- and protein-related increases had a significant linear correlation with the elastic modulus. In comparison, the MMP-9 gene and protein expressions were up-regulated in cardiac fibroblasts only, not in myocardial cells. These results implied that myocardial cells and cardiac fibroblasts in the myocardium could sense the stiffness in pathological fibrosis and showed a differential but positive response in the expression of matrix-degrading gelatinases when exposed to an increased stiffening of the matrix in the microenvironment. The phenomenon of cells sensing pathological matrix stiffness can help to increase understanding of the mechanism underlying myocardial fibrosis and may ultimately lead to planning cure strategies.

  14. Comparing the accuracy of ES-BC, EIS-GS, and ES Oxi on body composition, autonomic nervous system activity, and cardiac output to standardized assessments

    Directory of Open Access Journals (Sweden)

    Lewis JE

    2011-09-01

    Full Text Available John E Lewis1, Stacey L Tannenbaum1, Jinrun Gao3, Angelica B Melillo1, Evan G Long1, Yaima Alonso2, Janet Konefal1, Judi M Woolger2, Susanna Leonard1, Prabjot K Singh1, Lawrence Chen1, Eduard Tiozzo1 1Department of Psychiatry and Behavioral Sciences, 2Department of Medicine, University of Miami Miller School of Medicine, Miami, FL, 3State Farm Insurance, Bloomington, IL, USA Background and purpose: The Electro Sensor Complex (ESC is software that combines three devices using bioelectrical impedance, galvanic skin response, and spectrophotometry: (1 ES-BC (Electro Sensor-Body Composition; LD Technology, Miami, FL to assess body composition, (2 EIS-GS (Electro Interstitial Scan-Galvanic Skin; LD Technology to predict autonomic nervous system activity, and (3 ES Oxi (Electro Sensor Oxi; LD Technology to assess cardiac output. The objective of this study was to compare each to a standardized assessment: ES-BC to dual-energy X-ray absorptiometry (DXA, EIS-GS to heart rate variability, and ES Oxi to BioZ Dx Diagnostic System (BioZ Dx; SonoSite Inc, Bothell, WA. Patients and methods: The study was conducted in two waves. Fifty subjects were assessed for body composition and autonomic nervous system activity. Fifty-one subjects were assessed for cardiac output. Results: We found adequate relative and absolute agreement between ES-BC and DXA for fat mass (r = 0.97, P < 0.001 with ES-BC overestimating fat mass by 0.1 kg and for body fat percentage (r = 0.92, P < 0.001 with overestimation of fat percentage by 0.4%. For autonomic nervous system activity, we found marginal relative agreement between EIS-GS and heart rate variability by using EIS-GS as the predictor in a linear regression equation (adjusted R2 = 0.56, P = 0.03. For cardiac output, adequate relative and absolute agreement was found between ES Oxi and BioZ Dx at baseline (r = 0.60, P < 0.001, after the first exercise stage (r = 0.79, P < 0.001, and after the second exercise stage (r = 0.86, P

  15. Glucagon-like peptide-1 (7-36) but not (9-36) augments cardiac output during myocardial ischemia via a Frank-Starling mechanism.

    Science.gov (United States)

    Goodwill, Adam G; Tune, Johnathan D; Noblet, Jillian N; Conteh, Abass M; Sassoon, Daniel; Casalini, Eli D; Mather, Kieren J

    2014-01-01

    This study examined the cardiovascular effects of GLP-1 (7-36) or (9-36) on myocardial oxygen consumption, function and systemic hemodynamics in vivo during normal perfusion and during acute, regional myocardial ischemia. Lean Ossabaw swine received systemic infusions of saline vehicle or GLP-1 (7-36 or 9-36) at 1.5, 3.0, and 10.0 pmol/kg/min in sequence for 30 min at each dose, followed by ligation of the left circumflex artery during continued infusion at 10.0 pmol/kg/min. Systemic GLP-1 (9-36) had no effect on coronary flow, blood pressure, heart rate or indices of cardiac function before or during regional myocardial ischemia. Systemic GLP-1 (7-36) exerted no cardiometabolic or hemodynamic effects prior to ischemia. During ischemia, GLP-1 (7-36) increased cardiac output by approximately 2 L/min relative to vehicle-controls (p = 0.003). This response was not diminished by treatment with the non-depolarizing ganglionic blocker hexamethonium. Left ventricular pressure-volume loops measured during steady-state conditions with graded occlusion of the inferior vena cava to assess load-independent contractility revealed that GLP-1 (7-36) produced marked increases in end-diastolic volume (74 ± 1 to 92 ± 5 ml; p = 0.03) and volume axis intercept (8 ± 2 to 26 ± 8; p = 0.05), without any change in the slope of the end-systolic pressure-volume relationship vs. vehicle during regional ischemia. GLP-1 (9-36) produced no changes in any of these parameters compared to vehicle. These findings indicate that short-term systemic treatment with GLP-1 (7-36) but not GLP-1 (9-36) significantly augments cardiac output during regional myocardial ischemia, via increases in ventricular preload without changes in cardiac inotropy.

  16. GASTO CARDÍACO MATERNO COMO PREDICTOR DEL SÍNDROME DE PREECLAMPSIA-ECLAMPSIA / Maternal cardiac output as a predictor of preeclampsia-eclampsia syndrome

    Directory of Open Access Journals (Sweden)

    Luis A. Díaz Moreno

    2012-03-01

    Full Text Available Resumen Introducción y objetivos: La hipertensión es la complicación médica más común del embarazo, y puede dejar secuelas permanentes como: alteraciones neurológicas, hepáticas, hematológicas o renales. Cada tres minutos muere una mujer debido a la preeclampsia. Durante el embarazo el gasto cardíaco sufre un incremento de hasta 40 %. Este incremento es secundario al aumento de aproximadamente 30 % del volumen sistólico. El objetivo de la investigación fue predecir la aparición del síndrome de preeclampsia-eclampsia mediante la identificación de alteraciones del gasto cardíaco. Método: Se realizó un estudio observacional, descriptivo, longitudinal y analítico, de cohorte prospectiva, donde se determinó, por ecocardiografía, el gasto cardíaco en 31 embarazadas, entre las semanas 11 y 13,6 de gestación como único valor; y mediante seguimiento prenatal, se observó la aparición o no del síndrome de Preeclampsia-Eclampsia. Resultados: Se logró el seguimiento de 31 embarazadas a las que se le midió el gasto cardíaco, y se encontró una prevalecía de la enfermedad de 12,9 % con un 64,5 % de pacientes correctamente diagnosticados, con una sensibilidad de 75 %, con valor predictivo positivo de 23 %, especificidad de 62 % y valor predictivo negativo de 94%, con un riesgo relativo de 4,1 (intervalo de confianza 95 %, 0,48-35,6. Conclusiones: Es posible establecer la medición de gasto cardíaco como estudio de escrutinio para predecir la aparición del síndrome de Preeclampsia desde el control prenatal, y contribuir así a la disminución de la muerte materna. / Abstract Introduction and Objectives: Hypertension is the most common medical complication of pregnancy, and it can leave permanent sequelae such as neurological, hepatic, hematological or renal disorders. Every three minutes a woman dies due to preeclampsia. During pregnancy, cardiac output suffers an increase of 40%. This increase is secondary to an increase of

  17. 连续多普勒无创血液动力学监测仪(USCOM)在危重患者中的运用%The Application of Ultrasonic Cardiac Output Monitor In the Critically Ill Patients

    Institute of Scientific and Technical Information of China (English)

    杨勤; 向明芳

    2012-01-01

    Objective: To compare the cardiac output detected by ultrasonic cardiac output monitor(USCOM) and Thoracic Electrical Bioimpedance(TEB). Methods: The cardiac outputs of 40 critically ill patients were detected by USCOM and TEB simultaneously. Results: There was no significant difference of the cardiac output detected by USCOM and TEB(P>0.10), the correlation analysis showed a positive correlation between cardiac output measured with USCOM and TEB(correlation coefficient of CO: r=0.8427, correlation coefficient of SV: r=0.8392, P0.10);且两种监测方法测得的结果具有正相关性(CO相关系数 r=0.8427,SV相关系数 r=0.8392,P均<0.01).结论采用USCOM技术监测危重患者的心输出量具有无创、连续、简便、准确的特点.

  18. Comparison of cardiac power output and exercise performance in patients with left ventricular assist devices, explanted (recovered) patients, and those with moderate to severe heart failure.

    Science.gov (United States)

    Jakovljevic, Djordje G; George, Robert S; Donovan, Gay; Nunan, David; Henderson, Keiran; Bougard, Robert S; Yacoub, Magdi H; Birks, Emma J; Brodie, David A

    2010-06-15

    Peak cardiac power output (CPO), as a direct measurement of overall cardiac function, has been shown to be a most powerful predictor of prognosis for patients with chronic heart failure. The present study assessed CPO and exercise performance in patients implanted with a left ventricular assist device (LVAD), those explanted due to myocardial recovery, and those with moderate to severe heart failure. Hemodynamic and respiratory gas exchange measurements were undertaken at rest and at peak graded exercise. These were performed in 54 patients-20 with moderate to severe heart failure, 18 with implanted LVADs, and 16 with explanted LVADs. At rest there was a nonsignificant difference in CPO among groups (p >0.05). Peak CPO was significantly higher in the explanted LVAD than in the heart failure and implanted LVAD groups (heart failure 1.90 +/- 0.45 W, implanted LVAD 2.37 +/- 0.55 W, explanted LVAD 3.39 +/- 0.61 W, p <0.01) as was peak cardiac output (heart failure 9.1 +/- 2.1 L/min, implanted LVAD 12.4 +/- 2.2 L/min, explanted LVD 14.6 +/- 2.9 L/min, p <0.01). Peak oxygen consumption was higher in the explanted LVAD than in the heart failure and implanted LVAD groups (heart failure 15.8 +/- 4.1 ml/kg/min, implanted LVAD 19.8 +/- 5.8 ml/kg/min, explanted LVAD 28.2 +/- 5.0 ml/kg/min, p <0.05) as was anaerobic threshold (heart failure 11.2 +/- 1.9 ml/kg/min, implanted LVAD 14.7 +/- 4.9 ml/kg/min, explanted LVAD 21.4 +/- 5.0 ml/kg/min, p <0.05). In conclusion, peak CPO differentiates well during cardiac restoration using LVADs and emphasizes the benefits of this therapy. CPO has the potential to be a key physiologic marker of heart failure severity and can guide management of patients with LVAD.

  19. G16R single nucleotide polymorphism but not haplotypes of the ß2-adrenergic receptor gene alters cardiac output in humans

    DEFF Research Database (Denmark)

    Rokamp, Kim Z; Staalsø, Jonatan M; Gartmann, Martin

    2013-01-01

    Variation in genes encoding the ß2-adrenergic receptor (ADRB2) and angiotensin-converting enzyme (ACE) may influence Q¿ (cardiac output). The 46G>A (G16R) SNP (single nucleotide polymorphism) has been associated with ß2-mediated vasodilation, but the effect of ADRB2 haplotypes on Q¿ has not been...... studied. Five SNPs within ADRB2 (46G>A, 79C>G, 491C>T, 523C>A and 1053G>C by a pairwise tagging principle) and the I/D (insertion/deletion) polymorphism in ACE were genotyped in 143 subjects. Cardiovascular variables were evaluated by the Model flow method at rest and during incremental cycling exercise...

  20. Use of transesophageal Doppler as a sole cardiac output monitor for reperfusion hemodynamic changes during living donor liver transplantation: An observational study

    Directory of Open Access Journals (Sweden)

    M Hussien

    2011-01-01

    Full Text Available Aims: To report the use of transesophageal Doppler (TED, a minimally invasive cardiac output (COP monitor, before, during and after reperfusion and study its effect on anesthetic management during living donor liver transplantation (LDLT. Setting and Design: A prospective observational study. Methods: A total of 25 consecutive recipients with a MELD score between 15 and 20 were enrolled. Data were recorded at baseline (TB; anhepatic phase (TA; and post-reperfusion - 1, 5, 10 and 30 minutes. Fluid therapy was guided by corrected flow time (FTc of the TED. Packed red blood cells (RBCs were only given when hematocrit was less than 25%. Rotational thromboelastometry (ROTEM and standard laboratory tests were used to guide component blood products requirements. Results: Post-reperfusion, the COP, Cardiac Index (CI and stroke volume (SV increased significantly at all points of measurements; this was associated with a significant decrease in systemic vascular resistance (SVR ( P <.05. Immediately post-reperfusion, for 5 minutes, mean arterial blood pressure (ABP dropped significantly (P<.05, and 14 out of the 25 patients required boluses of epinephrine (10 μg to restore the mean ABP; 3 of the 14 patients required norepinephrine infusion till the end of surgery. Central venous pressure (CVP and urine output (UOP at all measures were maintained adequately with FTc-guided fluid replacement. Eight out of the 25 patients required no blood transfusion, and 4 of the 8 patients required no catecholamine support. Conclusion: TED as a sole monitor for COP was able to present significant and reliable changes in the cardiovascular status of the recipients during reperfusion, which could help to guide fluid- and drug-supportive therapy in this population of patients. This preliminary study needs to be applied on a larger scale.

  1. Direct recording of cardiac output- and venous return-curves in the dog heart-lung preparation for a graphical analysis of the effects of cardioactive drugs.

    Science.gov (United States)

    Ishikawa, N; Taki, K; Hojo, Y; Hagino, Y; Shigei, T

    1978-09-01

    The dog heart-lung preparations were prepared. The "equilibrium point", which could be defined as the point at which the cardiac output (CO)-curve and the venous return (VR)-curve crossed, when the CO and VR were plotted against the right atrial pressure, was recorded directly by utilizing an X-Y recorder. The CO-curve was obtained, as a locus of the equilibrium point, by raising and lowering the level of blood in the venous reservoir (competence test). The meaning of the procedure was shown to increase or decrease the mean systemic pressure, and to cause the corresponding parallel shift in the VR-curve. The VR-curve was obtained by changing myocardial contractility. When heart failure was induced by pentobarbital or by chloroform, the equilibrium point shifted downwards to the right, depicting the VR-curve. During development of the failure, the slopes of CO-curves decreased gradually. Effects of cinobufagin and norepinephrine were also analyzed. Utilization of the X-Y recorder enabled us to settle the uniform experimental conditions more easily, and to follow the effects of drugs continuously on a diagram equating the CO- and VR-curves (Gyton's scheme).

  2. Single session of sprint interval training elicits similar cardiac output but lower oxygen uptake versus ramp exercise to exhaustion in men and women

    Science.gov (United States)

    Horn, Trevor; Roverud, Garret; Sutzko, Kandice; Browne, Melissa; Parra, Cristina; Astorino, Todd A

    2016-01-01

    Sprint interval training (SIT) elicits comparable long-term adaptations versus continuous exercise training (CEX) including increased maximal oxygen uptake (VO2max) and fat utilization. However, there is limited research examining acute hemodynamic responses to SIT. The aim of this study was to examine hemodynamic responses to low-volume SIT. Active men (n=6, VO2max = 39.8 ± 1.7 mL/kg/min) and women (n=7, VO2max = 37.3 ± 5.7 mL/kg/min) performed a ramp-based VO2max test (RAMP) to determine workload for the SIT session. Subjects returned within 1 wk and completed a session of SIT consisting of six 30-s bouts of “all-out” cycling at 130% maximal workload (Wmax) interspersed with 120 s of active recovery. Continuously during RAMP and exercise and recovery in SIT, VO2 was obtained and thoracic impedance was used to estimate heart rate (HR), stroke volume (SV), and cardiac output (CO). Results revealed no significant differences in COmax (p = 0.12, 19.7 ± 2.4 L/min vs. 20.3 ± 1.8 L/min) but lower SVmax (p = 0.004, 110.4 ± 15.7 mL vs. 119.4 ± 15.5 mL) in RAMP versus SIT. HRmax from SIT (179.0 ± 11.8 b/min) was lower (p = 0.008) versus RAMP (184.4 ± 7.9 b/min). Peak VO2 (L/min) was lower (p Sprint interval training consisting of 3 min of supramaximal exercise elicits similar CO yet lower VO2 compared to RAMP.

  3. Cardiac output in idiopathic normal pressure hydrocephalus: association with arterial blood pressure and intracranial pressure wave amplitudes and outcome of shunt surgery

    Directory of Open Access Journals (Sweden)

    Eide Per K

    2011-02-01

    Full Text Available Abstract Background In patients with idiopathic normal pressure hydrocephalus (iNPH responding to shunt surgery, we have consistently found elevated intracranial pressure (ICP wave amplitudes during diagnostic ICP monitoring prior to surgery. It remains unknown why ICP wave amplitudes are increased in these patients. Since iNPH is accompanied by a high incidence of vascular co-morbidity, a possible explanation is that there is reduced vascular compliance accompanied by elevated arterial blood pressure (ABP wave amplitudes and even altered cardiac output (CO. To investigate this possibility, the present study was undertaken to continuously monitor CO to determine if it is correlated to ABP and ICP wave amplitudes and the outcome of shunting in iNPH patients. It was specifically addressed whether the increased ICP wave amplitudes seen in iNPH shunt responders were accompanied by elevated CO and/or ABP wave amplitude levels. Methods Prospective iNPH patients (29 were clinically graded using an NPH grading scale. Continuous overnight minimally-invasive monitoring of CO and ABP was done simultaneously with ICP monitoring; the CO, ABP, and ICP parameters were parsed into 6-second time windows. Patients were assessed for shunt surgery on clinical grade, Evan's index, and ICP wave amplitude. Follow-up clinical grading was performed 12 months after surgery. Results ICP wave amplitudes but not CO or ABP wave amplitude, showed good correlation with the response to shunt treatment. The patients with high ICP wave amplitude did not have accompanying high levels of CO or ABP wave amplitude. Correlation analysis between CO and ICP wave amplitudes in individual patients showed different profiles [significantly positive in 10 (35% and significantly negative in 16 (55% of 29 recordings]. This depended on whether there was also a correlation between ABP and ICP wave amplitudes and on the average level of ICP wave amplitude. Conclusions These results gave no

  4. FloTrac/Vigileo系统在单肺通气心输出量监测中应用的探讨%Investigation of FloTrac/Vigileo in monitoring cardiac output during one lung ventilation

    Institute of Scientific and Technical Information of China (English)

    王宏宇; 苏中宏; 史宏伟; 鲍红光

    2011-01-01

    观察FloTrac/Vigileo系统在单肺通气心输出量(CO)监测中的应用效果.方法择期单肺通气手术患者17例,ASAⅡ或Ⅲ级,使用FloTrac/Vigileo系统观察CO变化,记录诱导后(T0)、单肺通气5 min(T1)、10 min(T2)、30min(T3)以及双腔管双肺通气时(T4)、关胸时(T5)的HR、MAP、心脏指数(CI)、每搏量变异度(SVV)和气道峰压(Pmax).结果 与T0时比较,T1、T5时CI明显增加(P<0.05);T1~T5时SVV均明显下降(P<0.05);T1~T3时Pmax显著增加(P<0.05).结论 FloTrac/Vigileo系统能快速、持续地监测单肺通气时CO的变化.%Objective To investigate the efficacy of FloTrac/Vigileo in monitoring cardiac output during one lung ventilatioa Methods Seventeen ASA Ⅱ or Ⅲ patients requiring one lung ventilation (OLV) were enrolled in the study. Cardiac index (CD and stroke volume variation (SVV) were recorded using FloTrac/Vigileo after anesthesia induction (T0), 5 min after (T1), 10 min after (T2), 30 min after (T3) OLV, during double-lumen-endobronchial-tube ventilation (T4) and at closing thorax (T5). HR, MAP and airway pressure were also recorded at these time points. Results Compared with T0, CI increased significantly at T1 and T5 (P<0. 05); SW decreased significantly from T1 to T5 (P<0. 05); and Pmax increased significantly from T1 to T3 (P<0. 05). Conclusion FloTrac/Vigileo can be used to rapidly and continuously monitor cardiac output during one lung ventilation continuously.

  5. 静脉输注氨茶碱治疗严重脓毒症的可行性%Effects of aminophylline on cardiac index,oxygenation index, urine output and APACHEⅡ in patients with sepsis

    Institute of Scientific and Technical Information of China (English)

    代冬梅; 王飞; 许汪斌; 杨磊; 谢翠英

    2013-01-01

    Objective To investigate the effects of aminophylline on cardiac index, oxygenation index and urine output in patients with sepsis. Methods Sixty APACHE Ⅱ score > 16 points patients with spesis of both sexes, aged 22 -76yr, were randomly divided into 2 groups( n = 30 each ) : aminophylline group ( group A ) and control group( group C ). Mechanical ventilation, antibiotics according to susceptibility or the sites of infection, early goal - directed therapy and low - dose steroids were administered for septic shock in both groups. Aminophylline 3mg/kg was infused iv over 30 min and followed by an infusion at 0. 4 mg/( kg·h ) for 4 days. Cardiac index, stroke volume variation and invasive arterial blood pressure were continuously monitored. Blood samples were drawn for blood gas analysis calculating oxygenation index and for determination of aminophylline serum concentration before aminophylline infusion( T0) and at 24h( T1), 48h( T2 ) and 72 h( T3 ) following aminophylline infusion. Urine output and total daily infusion were recorded at T0- T3. Results There were no significant differences in age, gender ratios, height, weight, APACHE Ⅱ scores, and total daily infusion between two groups ( P>0. 05 ). Compared with group C, there were no significant differences in the total daily infusion, cardiac index, oxygenation index and urine output before intravenous infusion of aminophylline ( P >0. 05 ). Compared with the values before intravenous infusion of aminophylline ( T0), oxygenation index and urine output increased in two groups ( P 0. 05 ), but it increased at T1 and T3( P 0. 05 ). Conclusion Intravenous infusion of aminophylline can increase urine output, oxygenation index and cardiac index in patients with sepsis.%目的 观察静脉输注氨茶碱对严重脓毒症患者氧合指数、尿量、心脏指数和APACHEII评分的影响,探讨静脉输注氨茶碱治疗脓毒症的可行性.方法 将60例APACHE 评分>16分的脓毒症患者随机分为氨茶

  6. Predictive factors related to low cardiac output syndrome following aortic valve replacement%主动脉瓣置换术后发生低心排出量综合征的预测因素探讨

    Institute of Scientific and Technical Information of China (English)

    马红; 张其霞; 李晓静; 郑晓燕

    2014-01-01

    Objective To investigate the predictive factors related to postoperative low cardiac output syndrome in pa-tients after aortic valve replacement due to aortic stenosis or regurgitation. Methods Three hundred patients with aortic valve defect due to aortic stenosis (AS, n=150) or aortic incompetence (AI, n=150), who underwent isolated aortic valve replacement were included in the study. Low cardiac output syndrome(LOS) was defined as the need for high dosages of inotropic medication, and/or intra- aortic bal oon pumping to sustain adequate hemodynamic status. Results Postoperative low cardiac output syn-drome developed in 86 patients (28.6%), including 39 patients with AS (26.0%) and 47 patients with AI (31.3%). The development of postoperative LOS were associated with the fol owing factors (odds ratio in parentheses): for AS group: advanced age (OR=4.7), obesity (OR=1.8), history of heart failure (OR=1.7), end- systolic (OR=5.5) and end- diastolic intraventricular septum thickness (OR=4.2), left atrial diameter (OR=1.6), mitral and tricuspid regurgitation (OR=1.9, 1.5) before surgery, LVEF≤50.0%(OR=5.4), left ventricular end systolic diameter (OR=1.7), left ventricular end diastolic diameter (OR=1.9) and mitral regurgitation (OR=4.1) in early postoperative period; for AI group:advanced age (OR=1.9), obesity (OR=4.8), history of heart failure (OR=1.7), LVEF≤50.0%(OR=1.8), left ventricular end- systolic (OR=4.5), end- diastolic diameters (OR=6.4), left ventricular end systolic di-ameter (OR=1.5), left ventricular end diastolic diameter(OR=1.6), and tricuspid regurgitation (OR=1.5) in preoperative period and left ventricular end- systolic (OR=4.7) and end- diastolic diameters (OR=6.1), and LVEF≤50.0% (OR=7.2) in early postoperative period. Conclusion The patients at high risk for the development of low cardiac output syndrome should be the focus of trials of new techniques of myocardial protection to effectively resuscitate the ischemic myocardium and

  7. EVALUACIÓN ECOCARDIOGRÁFICA DEL GASTO CARDÍACO SISTÉMICO EN LA ATRESIA PULMONAR CON SEPTO INTERVENTRICULAR INTACTO / Echocardiographic evaluation of cardiac output in pulmonary atresia with intact ventricular septum

    Directory of Open Access Journals (Sweden)

    Giselle Serrano Ricardo

    2013-07-01

    hemodynamic performance, influencing cardiac output and generating potential conditions for short-term prognosis. Method: A descriptive, prospective and applied study was conducted. It included 43 patients who were referred to the William Soler Pediatric Cardiology Hospital from January 1992 to November 2011 with a diagnosis of the disease. In each subject, the profiles of eight echocardiographic variables were assessed, as well as the heart rate profile. Their level of association and mutual dependence were statistically assessed by simple regression models. Results: There are considerable variations in heart rate, in the volume index and in the ejection fraction of the patients´ left ventricle compared with those in the reference control group. Conclusions: The increased size of the atrial septal defect and the prolongation of transmitral diastasis favor left ventricular volume increment. Heart rate, the restrictive nature of the left ventricular myocardium and its ejection fraction are regulatory factors of cardiac output in this disease.

  8. Infliximab reduces cardiac output in rheumatoid arthritis patients without heart failure Infliximabe reduz débito cardíaco em pacientes com artrite reumatoide sem insuficiência cardíaca

    Directory of Open Access Journals (Sweden)

    Rodrigo Cardoso Santos

    2012-12-01

    Full Text Available OBJECTIVE: Human anti-tumor necrosis factor (TNF-α monoclonal antibody (infliximab is used to treat autoimmune diseases such as rheumatoid arthritis (RA. Although the risk of worsening heart failure has been described in patients under chronic treatment, the acute cardiovascular effects of this drug are unknown in RA patients without heart failure. METHODS: 14 RA patients with normal echocardiography and no history of heart failure were evaluated during the 2-hour infliximab (3-5 mg/kg infusion period, using a noninvasive hemodynamic beat-to-beat system (Portapres. Stroke volume (SV; systolic, diastolic and mean blood pressures (SBP, DBP and MBP, respectively; cardiac output (CO; heart rate (HR; and total peripheral vascular resistance (PVR were recorded. All patients also received saline infusion instead of infliximab as a control. Significant differences in hemodynamic parameters were determined using Tuckey's test. All values were expressed as mean ± standard deviation (SD. RESULTS: Fourteen RA patients (6M/8F with mean age of 47.2 ± 8.8 years were evaluated. A significant decrease was found in cardiac output and stroke volume (7.04 ± 2.3 to 6.12 ± 2.1 l/min and 91 ± 29.0 to 83 ± 28.8 mL/beat, respectively after infliximab infusion. Although not statistically significant, a progressive increase was detected in SBP, DBP and total PVR during infusion. Saline infusion did not cause significant hemodynamic changes in the same group of RA patients. No adverse effects were observed during the infusion period. CONCLUSION: Acute infliximab administration decreased cardiac output due to low stroke volume in RA patients without heart disease. The results also demonstrated that, in spite of its negative inotropic effect, infliximab enhanced BP, probably by increasing PVR.OBJETIVO: O inibidor de fator de necrose tumoral (TNF-α infliximabe é usado no tratamento de doenças autoimunes como a artrite reumatoide (AR. Embora o risco de piora de

  9. Application of peritoneal dialysis in the treatment of children with low cardiac output after cardiosurgery%腹膜透析在小儿先天性心脏病术后低心排的应用

    Institute of Scientific and Technical Information of China (English)

    王风

    2014-01-01

    Objective To investigate the effect of peritoneal dialysis in the treatment of children with low cardiac output after cardiosurgery .Methods A retrospective analysis was performed on the therapeutic effect of 12 children with low cardiac output after surgery of congenital heart disease by the early peritoneal dialysis in our hospital , 2.5%low calcium peritoneal dialysis solution was selected .The single amount of peritoneal dialysis was 15~20 ml/kg, and dialysis fluid retention time was 20~30 min.After 30 min reservation, dialysis fluid was drained for about 20 min according to the blood pressure .Peritoneal dialysis interval time was extended gradually after the urine occurred .Re-tention time of peritoneal dialysis was extended if patients were suffered from hyperlactacidemia .The frequency of di-alysis was adjusted according to the the level of serum creatinine and lactate .The blood glucose , electrolytes as well as arterial and venous blood gas was monitored , and the colloid was supplied when necessary .The peritoneal dialysis start, duration and the urine recovery time was recorded .Results The urine recovery time was 5~22 h.The appli-cation time of ventilator was 70~128 h, and the time in ICU was 5~18 d.The complications of peritoneal dialysis included catheter blockage (3 cases), hypoglycemia(3 cases), hyperglycemia(1 case) and hypokalemia (2 cases). No patients suffered from peritonitis and intestinal perforation .Two cases of tetralogy of fallot were died of severe low cardiac output and multiple organ dysfunction .Conclusion Early application of peritoneal dialysis can reduce the burden of heart , lung and kidney , maintain the stability of internal environment , and reduce mortality .%目的观察腹膜透析对小儿先天性心脏病术后的低心排治疗效果。方法回顾性分析该院12例先天性心脏病术后低心排早期治疗使用腹膜透析效果。腹透液选择百特公司2.5%低钙腹膜透析液。单次腹膜透析量15

  10. Regulation of Cardiac Hypertrophy: the nuclear option

    NARCIS (Netherlands)

    D.W.D. Kuster (Diederik)

    2011-01-01

    textabstractCardiac hypertrophy is the response of the heart to an increased workload. After myocardial infarction (MI) the surviving muscle tissue has to work harder to maintain cardiac output. This sustained increase in workload leads to cardiac hypertrophy. Despite its apparent appropriateness, c

  11. Application of pulse index continuous cardiac output monitoring to improve efficiency of acute heart failure care%应用脉搏指数连续心输出量监测提升急性心力衰竭护理效果

    Institute of Scientific and Technical Information of China (English)

    孙秀月; 张领; 赵书琴

    2015-01-01

    Objective To ihvestigate the effect of pulse index continuous cardiac output (PiCCO) monitoring to nursing care of acute heart failure care.Methods The clinical data of 43 acute heart failure patients were retrospectively analyzed,patients were given pulse index continuous cardiac output monitoring and care,the patient' s nursing outcomes were observed,and the intrathoracic blood volume,cardiac output and oxygen consumption before and after the intervention were compared.Results After the implementation of PiCCO and nursing intervention,43 patients had no serious complications,improved 42 cases discharged,the other 1 patient in critical condition due to old age and heart function improvement sustained no automatic discharge.Oxygen consumption,cardiac output and intrathoracic blood volume were improved after the intervention,there was a significant difference (P < 0.05) compared to the previous indicators and intervention after intervention.Conclusions Application of pulse index continuous cardiac output can effectively improve patient's clinical parameters such as cardiac output,through the implementation of appropriate care can improve symptoms and reduce complications.%目的 探讨急性心力衰竭患者护理中应用脉搏指数连续心输出量监测(PiCCO)的效果.方法 选取平顶山市第二人民医院收治的43例急性心力衰竭患者作为研究对象,收集患者的临床资料并对其做回顾性分析,对患者实施脉搏指数连续心输出量监测和护理,对患者的护理效果进行观察,并对其干预前后的胸腔内血容量、心排血量与氧耗量进行对比观察.结果 实施PiCCO和护理干预,本研究43例患者均无严重并发症产生,42例好转出院,1例由于病情危重、高龄及心功能持续无改善自动出院.患者干预后的氧耗量、心排血量与胸腔内血容量均有所改善,干预后各项指标与干预前比较差异有统计学意义(P<0.05).结论 应用脉搏指数连续心

  12. Bioimpedância transtorácica comparada à ressonância magnética na avaliação do débito cardíaco Transthoracic impedance compared to magnetic resonance imaging in the assessment of cardiac output

    Directory of Open Access Journals (Sweden)

    Humberto Villacorta Junior

    2012-12-01

    Full Text Available FUNDAMENTO: A ressonância magnética cardíaca é considerada o método padrão-ouro para o cálculo de volumes cardíacos. A bioimpedância transtorácica cardíaca avalia o débito cardíaco. Não há trabalhos que validem essa medida comparada à ressonância. OBJETIVO: Avaliar o desempenho da bioimpedância transtorácica cardíaca no cálculo do débito cardíaco, índice cardíaco e volume sistólico, utilizando a ressonância como padrão-ouro. MÉTODOS: Avaliados 31 pacientes, com média de idade de 56,7 ± 18 anos, sendo 18 (58% do sexo masculino. Foram excluídos os pacientes cuja indicação para a ressonância magnética cardíaca incluía avaliação sob estresse farmacológico. A correlação entre os métodos foi avaliada pelo coeficiente de Pearson, e a dispersão das diferenças absolutas em relação à média foi demonstrada pelo método de Bland-Altman. A concordância entre os métodos foi realizada pelo coeficiente de correlação intraclasses. RESULTADOS: A média do débito cardíaco pela bioimpedância transtorácica cardíaca e pela ressonância foi, respectivamente, 5,16 ± 0,9 e 5,13 ± 0,9 L/min. Observou-se boa correlação entre os métodos para o débito cardíaco (r = 0,79; p = 0,0001, índice cardíaco (r = 0,74; p = 0,0001 e volume sistólico (r = 0,88; p = 0,0001. A avaliação pelo gráfico de Bland-Altman mostrou pequena dispersão das diferenças em relação à média, com baixa amplitude dos intervalos de concordância. Houve boa concordância entre os dois métodos quando avaliados pelo coeficiente de correlação intraclasses, com coeficientes para débito cardíaco, índice cardíaco e volume sistólico de 0,78, 0,73 e 0,88, respectivamente (p BACKGROUND: Cardiac magnetic resonance imaging is considered the gold-standard method for the calculation of cardiac volumes. Transthoracic impedance cardiography assesses the cardiac output. No studies validating this measurement, in comparison to that obtained

  13. Bioimpedância transtorácica comparada à ressonância magnética na avaliação do débito cardíaco Transthoracic impedance compared to magnetic resonance imaging in the assessment of cardiac output

    Directory of Open Access Journals (Sweden)

    Humberto Villacorta Junior

    2012-01-01

    Full Text Available FUNDAMENTO: A ressonância magnética cardíaca é considerada o método padrão-ouro para o cálculo de volumes cardíacos. A bioimpedância transtorácica cardíaca avalia o débito cardíaco. Não há trabalhos que validem essa medida comparada à ressonância. OBJETIVO: Avaliar o desempenho da bioimpedância transtorácica cardíaca no cálculo do débito cardíaco, índice cardíaco e volume sistólico, utilizando a ressonância como padrão-ouro. MÉTODOS: Avaliados 31 pacientes, com média de idade de 56,7 ± 18 anos, sendo 18 (58% do sexo masculino. Foram excluídos os pacientes cuja indicação para a ressonância magnética cardíaca incluía avaliação sob estresse farmacológico. A correlação entre os métodos foi avaliada pelo coeficiente de Pearson, e a dispersão das diferenças absolutas em relação à média foi demonstrada pelo método de Bland-Altman. A concordância entre os métodos foi realizada pelo coeficiente de correlação intraclasses. RESULTADOS: A média do débito cardíaco pela bioimpedância transtorácica cardíaca e pela ressonância foi, respectivamente, 5,16 ± 0,9 e 5,13 ± 0,9 L/min. Observou-se boa correlação entre os métodos para o débito cardíaco (r = 0,79; p = 0,0001, índice cardíaco (r = 0,74; p = 0,0001 e volume sistólico (r = 0,88; p = 0,0001. A avaliação pelo gráfico de Bland-Altman mostrou pequena dispersão das diferenças em relação à média, com baixa amplitude dos intervalos de concordância. Houve boa concordância entre os dois métodos quando avaliados pelo coeficiente de correlação intraclasses, com coeficientes para débito cardíaco, índice cardíaco e volume sistólico de 0,78, 0,73 e 0,88, respectivamente (p BACKGROUND: Cardiac magnetic resonance imaging is considered the gold-standard method for the calculation of cardiac volumes. Transthoracic impedance cardiography assesses the cardiac output. No studies validating this measurement, in comparison to that obtained

  14. Application of pulse contour cardiac output monitoring technique in hemodynamic monitoring in critical patients%脉搏轮廓心排血量监测技术在危重病患者血流动力学监测中的应用

    Institute of Scientific and Technical Information of China (English)

    房贺; 郑兴锋; 夏照帆

    2014-01-01

    Pulse contour cardiac output (PiCCO) monitoring is a new type of invasive hemodynamic monitoring technology,which is more and more often applied in perioperative period and the patients suffering from multiple injuries,septic shock,and extensive burn.With PiCCO one is able to monitor patients' hemodynamic indexes safely,timely,accurately,and continuously to provide reference for judgment of patients' condition and proper quality and quantity of fluid administration.This technique has a good prospect in clinical application.

  15. Adaptive Output Tracking of Driven Oscillators

    Directory of Open Access Journals (Sweden)

    Lili Diao

    2008-01-01

    of the output tracking error to an adjustable neighborhood of the origin. In addition, good approximation of the unknown nonlinearities is also achieved by incorporating a persistent exciting signal in the parameter update law. The effectiveness of the proposed method is demonstrated by an application to a cardiac conduction system modelled by two coupled driven oscillators.

  16. External cardiac compression may be harmful in some scenarios of pulseless electrical activity.

    LENUS (Irish Health Repository)

    Hogan, T S

    2012-10-01

    Pulseless electrical activity occurs when organised or semi-organised electrical activity of the heart persists but the product of systemic vascular resistance and the increase in systemic arterial flow generated by the ejection of the left venticular stroke volume is not sufficient to produce a clinically detectable pulse. Pulseless electrical activity encompasses a very heterogeneous variety of severe circulatory shock states ranging in severity from pseudo-cardiac arrest to effective cardiac arrest. Outcomes of cardiopulmonary resuscitation for pulseless electrical activity are generally poor. Impairment of cardiac filling is the limiting factor to cardiac output in many scenarios of pulseless electrical activity, including extreme vasodilatory shock states. There is no evidence that external cardiac compression can increase cardiac output when impaired cardiac filling is the limiting factor to cardiac output. If impaired cardiac filling is the limiting factor to cardiac output and the heart is effectively ejecting all the blood returning to it, then external cardiac compression can only increase cardiac output if it increases venous return and cardiac filling. Repeated cardiac compression asynchronous with the patient\\'s cardiac cycle and raised mean intrathoracic pressure due to chest compression can be expected to reduce rather than to increase cardiac filling and therefore to reduce rather than to increase cardiac output in such circumstances. The hypothesis is proposed that the performance of external cardiac compression will have zero or negative effect on cardiac output in pulseless electrical activity when impaired cardiac filling is the limiting factor to cardiac output. External cardiac compression may be both directly and indirectly harmful to significant sub-groups of patients with pulseless electrical activity. We have neither evidence nor theory to provide comfort that external cardiac compression is not harmful in many scenarios of pulseless

  17. External cardiac compression may be harmful in some scenarios of pulseless electrical activity.

    Science.gov (United States)

    Hogan, T S

    2012-10-01

    Pulseless electrical activity occurs when organised or semi-organised electrical activity of the heart persists but the product of systemic vascular resistance and the increase in systemic arterial flow generated by the ejection of the left venticular stroke volume is not sufficient to produce a clinically detectable pulse. Pulseless electrical activity encompasses a very heterogeneous variety of severe circulatory shock states ranging in severity from pseudo-cardiac arrest to effective cardiac arrest. Outcomes of cardiopulmonary resuscitation for pulseless electrical activity are generally poor. Impairment of cardiac filling is the limiting factor to cardiac output in many scenarios of pulseless electrical activity, including extreme vasodilatory shock states. There is no evidence that external cardiac compression can increase cardiac output when impaired cardiac filling is the limiting factor to cardiac output. If impaired cardiac filling is the limiting factor to cardiac output and the heart is effectively ejecting all the blood returning to it, then external cardiac compression can only increase cardiac output if it increases venous return and cardiac filling. Repeated cardiac compression asynchronous with the patient's cardiac cycle and raised mean intrathoracic pressure due to chest compression can be expected to reduce rather than to increase cardiac filling and therefore to reduce rather than to increase cardiac output in such circumstances. The hypothesis is proposed that the performance of external cardiac compression will have zero or negative effect on cardiac output in pulseless electrical activity when impaired cardiac filling is the limiting factor to cardiac output. External cardiac compression may be both directly and indirectly harmful to significant sub-groups of patients with pulseless electrical activity. We have neither evidence nor theory to provide comfort that external cardiac compression is not harmful in many scenarios of pulseless

  18. Consenso brasileiro de monitorização e suporte hemodinâmico - parte III: métodos alternativos de monitorização do débito cardíaco e da volemia Brazilian consensus of monitoring and hemodynamic support - part III: alternative methods for cardiac output monitoring and volemia estimation

    Directory of Open Access Journals (Sweden)

    Guilherme Schettino

    2006-03-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: A interpretação do débito cardíaco e da pré-carga como números absolutos não traz grandes informações sobre a hemodinâmica do paciente crítico. Em contrapartida, a monitorização da resposta do débito cardíaco à expansão volêmica ou suporte inotrópico é uma ferramenta muito útil na unidade de terapia intensiva, quando o paciente apresenta algum sinal de má perfusão tecidual. Apesar do CAP ser considerado como " padrão-ouro" na avaliação destes parâmetros, foram desenvolvidas tecnologias alternativas bastante confiáveis para a sua monitorização. MÉTODO: O processo de desenvolvimento de recomendações utilizou o método Delphi modificado para criar e quantificar o consenso entre os participantes. A AMIB determinou um coordenador para o consenso, o qual escolheu seis especialistas para comporem o comitê consultivo. Outros 18 peritos de diferentes regiões do país foram selecionados para completar o painel de 25 especialistas, médicos e enfermeiros. Um levantamento bibliográfico na MEDLINE de artigos na língua inglesa foi realizado no período de 1966 a 2004. RESULTADOS: Foram apresentadas recomendações referentes à análise da variação da pressão arterial durante ventilação mecânica, débito cardíaco contínuo por contorno de pulso arterial, débito cardíaco por diluição do lítio, Doppler transesofágico, bioimpedância transtorácica, ecocardiografia e reinalação parcial de gás carbônico. CONCLUSÕES: As novas e menos invasivas técnicas para medida do débito cardíaco, pré-carga e fluidoresponsividade apresentam adequada precisão e podem ser uma alternativa ao uso do CAP em pacientes graves.BACKGROUND AND OBJECTIVES: Cardiac output and preload as absolute data do not offer helpful information about the hemodynamic of critically ill patients. However, monitoring the response of these variables to volume challenge or inotropic drugs is a very useful tool in the

  19. Cardiac arrest

    Science.gov (United States)

    ... Article.jsp. Accessed June 16, 2014. Myerburg RJ, Castellanos A. Approach to cardiac arrest and life-threatening ... PA: Elsevier Saunders; 2011:chap 63. Myerburg RJ, Castellanos A. Cardiac arrest and audden aardiac death. In: ...

  20. The application of pulse indication contour cardiac output to early fluid resuscitation in patients with septic shock%脉搏轮廓法在感染性休克早期液体复苏中的运用

    Institute of Scientific and Technical Information of China (English)

    李家琼; 李茂琴; 许继元; 史载祥; 张舟; 李琳; 卢飞; 莫逊; 许艳军

    2011-01-01

    液体复苏及血管活性药应用,能更精确进行液体管理,减少盲目补液,减少机械通气时间,缩短住ICU时间.%Objective To explore the use of pulse indication contour cardiac output (PiCCO) as a guidance for fluid resuscitation and vasopressors employment in patients with septic shock in order to find out the efficacy of this resuscitation strategy in the respect of outcome of patients. Mtthod A total of 30 patients with septic shock were treated with the EDGT fluid treatment protocol as the conventional treatment group from December 2006 to June 2008; and another 26 patients were given fluid treatment under the guidance of PiCCO as PiCCO group from July 2008 to October 2009. Exclusion criteria included patients with history of heart and lung diseases, and liver and kidney dysfunction. The mean arterial blood pressure was maintained above or equal to 65mmHg in PiCCO group,and fluid resuscitation was concluded when global end-diastolic volume index reached 600~750 mL·-2 with the stroke volume variation in < 10% and without auricular fibrillation. Nor-epinephrine was administrated to adiust the systemic peripheral vascular resistance index during 1300~1500 d·s·cm-5·m-2.Dobutamine was empoyed when global ejection fraction was compromised. The options of liquid and diuretics depend upon the presence d extra-vascular lung water. Central venous oxygen saturation and the level of lactate were observed 6hours after resuscitation. The liquid equilibrium for 3 days and the dosage of vasopressors were also recorded. The rate of survival, the time taken for weaning from mechanical ventilation, the days of ICU stay and rate of intact organ function within 28 days were compared between two groups. Results The demphics of patients of two goups were similar. There were no significant difference between PiCCO and the conventional group in values of central venous oxygen saturation and lactate 6 hours after admission to ICU (P > 0.05). And 6 h and 1d

  1. Clinical evaluation of the accuracy of the USCOM ultrasonic cardiac output monitor in the septic shock patients%无创超声心输出量测定对急诊感染性休克患者血流动力学状态评价的临床研究

    Institute of Scientific and Technical Information of China (English)

    刘继海; 于学忠; 王仲; 朱华栋; 徐胜勇

    2011-01-01

    目的 对急诊感染性休克患者同时进行脉搏波形指示的连续心输出量(pulse indicated continuous cardiac output, PiCCO)监测技术和无创超声心输出量测定,以有创血流动力学监测的数值作为标准,对无创超声心输出量测定方法的可靠性进行评价.方法 本试验为前瞻性研究,2008-06~2009-06北京协和医院急诊科抢救室和EICU收治32例明确诊断为感染性休克的患者,对这些患者同时进行无创超声心输出量测定和PiCCO监测,对比两者在心脏指数(cardiac index, CI)这一血流动力学核心指标上的差异,以评价无创超声心输出量测定在急诊应用中的可靠性.结果 共有30例患者同时获得了满意的血流超声多普勒影像,其中男性20例,女性10例,最小年龄26岁,最大年龄89岁,另2例患者因无法获得满意的超声结果而放弃.对比结果显示,在获得满意超声多普勒影像的前提下,无创超声心输出量和PiCCO测定的CI分别为(3.89±1.61)L/(min·m2)和(4.35±1.72)L/(min·m2)(Pearson相关系数=0.97165,P<0.0001).结论 无创超声心输出量测定是一项准确、快速、安全、无创的血流动力学监测技术,比较适合急诊患者的应用.%Objective The USCOM ultrasonic cardiac output monitor ( USCOM Pty Ltd, Coffs Harbour, NSW, Australia) is a non - invasive device that determines cardiac output by continuouswave Doppler ultrasound. The aim of this study was to evaluate the accuracy of the USCOM device compared with the PiCCO ( pulse indicated continuous cardiac output) technique on the septic shock patients in Emergency Room and Emergency Intensive Care Unit in Peking Union Medical College Hospital. Methods We conducted a prospective study in Emergency Room and Emergency Intensive Care Unit in Peking Union Medical College Hospital from June lst, 2008 to May 3lst, 2009. Thirty -two patients who were diagnosed as septic shock were recruited in this study. We evaluated the USCOM monitor by

  2. Pediatric cardiac postoperative care

    Directory of Open Access Journals (Sweden)

    Auler Jr. José Otávio Costa

    2002-01-01

    Full Text Available The Heart Institute of the University of São Paulo, Medical School is a referral center for the treatment of congenital heart diseases of neonates and infants. In the recent years, the excellent surgical results obtained in our institution may be in part due to modern anesthetic care and to postoperative care based on well-structured protocols. The purpose of this article is to review unique aspects of neonate cardiovascular physiology, the impact of extracorporeal circulation on postoperative evolution, and the prescription for pharmacological support of acute cardiac dysfunction based on our cardiac unit protocols. The main causes of low cardiac output after surgical correction of heart congenital disease are reviewed, and methods of treatment and support are proposed as derived from the relevant literature and our protocols.

  3. Early assessment of post-operative cardiac output and causes of death in the neonates with congenital heart diseases%新生儿先天性心脏病术后早期心排血量评估及死亡原因分析

    Institute of Scientific and Technical Information of China (English)

    仇黎生; 刘锦纷; 徐志伟; 朱丽敏; 徐卓明

    2010-01-01

    目的 通过对先天性心脏病术后心排血量的评估,分析新生儿心脏术后早期较高病死率的原因,并探讨早期干预降低病死率的方法.方法 2007年1~11月,体外循环复杂先心病手术后新生儿47例,平均年龄(21.98±8.15)天.死亡4例.分析心排血量的心指数(CI)与心肌肌钙蛋白I(cTnI)、体外循环时间、混合静脉血氧饱和度(SvO_2)的相关性,总结影响新生儿心脏术后心功能的高危因素,提出围术期治疗的优化方案.结果 新生儿心脏术后早期cI值平均(2.0±0.3)L~(-1)·min~(-1)·m~(-2),小于正常值(2.5±0.3)L~(-1)·min~(-1)·m~(-2);CI值和体外循环时间负相关、与SvO_2值正相关、与cTnI值相关性无统计学意义.cTnI值改变与手术操作有关.结论 新生儿心脏术后心排血量稍低于正常值,但能满足全身脏器的氧需.新生儿心脏术后早期的较高病死率与术前存在严重酸中毒、本身疾病的复杂性、过长的体外循环时间及残留的解剖畸形有关.提高手术技术,消除残留的解剖畸形,减少体外循环时间,对危重病例尽早干预可降低病死率.%Objective To evaluate accurately the cardiac output, an early post-operative indicator for the cardiac function, after cardiac surgery in the neonates with congenital heart diseases and assess the risk factors for surgery, with an aim at exploring the early strategy for decressing the mortality. Methods From January 2007 to November 2007, forty-seven consec-utive neonates with complex congenital heart diseases underwent surgical correction at Shanghai Children's medical center.There were 38 boys and 9 girls with age from 3 days to 29 days [mean age (21.98 +8.15) days] and weight from 2.6 kg to 4.2 kg [ mean (3.49±0.51 ) kg]. 15 patients had delayed sternal clousure. The operations were performed with hypothermia, deep hypothermia low flow, or deep hypothermia circulatory arrest techniques. Cardiac index (CI) was derived from pulse contour

  4. 超声心动图对中晚孕正常胎儿心排血量及主动脉峡部血流量的研究%Research on cardiac output and blood flow of aortic isthmus of normal fetus in middle and late pregnancy by echocardiography

    Institute of Scientific and Technical Information of China (English)

    陈桂红; 张燕宏; 米杰; 张晓云; 李伟娟; 孙聪欣; 梁丽华; 刘涛; 王玮婧

    2014-01-01

    Objective To explore the changes of cardiac output and distribution with the increasing of pregnancy week in normal fetuses of middle and late pregnancy and establish the normal reference range.Methods Three hundred and thirteen normal fetuses in 20-40 pregnancy weeks underwent fetal echocardiography.The largest diameters of aortic valve,pulmonary valve,ductus arteriosus,aortic isthmus were measured respectively in the left ventricular outflow view,right ventricular outflow view,three vessels view and aortic arch longitudinal view.The blood flow spectrums of these parts were acquired and its velocity time integral (VTI) and heart rate (HR) were got by automatic envelope model.According to the formula of Q =(diameter/2)2 × 3.14 × VTI × HR,the cardiac output of left and right ventricle,the blood flow of aortic isthmus and ductus arteriosus were calculated.Results The cardiac outputs of left and right ventricle,combined cardiac output and the blood flow of aortic isthmus and ductus arteriosus of normal fetuses in middle and late pregnancy gradually increased with the increasing of gestational age and there were linear positive correlation between them.The blood flow of aortic isthmus increased with fetal weight,and there was significant correlation between them.The ratio of blood flow of aortic isthmus and ductus arteriosus decreased gradually with the increasing pregnancy week,and there was linear negative relationship between them.The ratio of blood flow of aortic isthmus and output of left ventricle and the ratio of blood flow of aortic isthmus and cardiac output were relatively constant,and there was poor correlation with gestational age.Conclusions Quantification of cardiac output and blood flow of AI can improve understanding about fetal circulation system physiology and help to identify abnormal pathological conditions,especially prompt the late morphological changes because of early abnormal flow of aortic isthmus.There was high clinical value for

  5. Cardiac Sarcoidosis.

    Science.gov (United States)

    Birnie, David; Ha, Andrew C T; Gula, Lorne J; Chakrabarti, Santabhanu; Beanlands, Rob S B; Nery, Pablo

    2015-12-01

    Studies suggest clinically manifest cardiac involvement occurs in 5% of patients with pulmonary/systemic sarcoidosis. The principal manifestations of cardiac sarcoidosis (CS) are conduction abnormalities, ventricular arrhythmias, and heart failure. Data indicate that an 20% to 25% of patients with pulmonary/systemic sarcoidosis have asymptomatic (clinically silent) cardiac involvement. An international guideline for the diagnosis and management of CS recommends that patients be screened for cardiac involvement. Most studies suggest a benign prognosis for patients with clinically silent CS. Immunosuppression therapy is advocated for clinically manifest CS. Device therapy, with implantable cardioverter defibrillators, is recommended for some patients.

  6. [Effects of temporary dual-chamber cardiac pacing in refractory cardiac failure].

    Science.gov (United States)

    Scanu, P; Lecluse, E; Michel, L; Bureau, G; Saloux, E; Cleron, S; Valette, B; Grollier, G; Potier, J C; Foucault, J P

    1996-12-01

    The authors studied 18 patients (15 men, 3 women) with an average age of 67 +/- 8 years with refractory cardiac failure. In order to determine the potential of pacing to raise cardiac output in severe cardiac failure. The average ejection fraction was 26 +/- 6.5%. All patients were in sinus rhythm:resting cardiac output was 3.35 l/min. Two temporary pacing catheters were positioned in the right atrium and at the apex of the right ventricle for dual-chamber mode pacing triggered by the spontaneous P waves. Changes in cardiac output were measured by Doppler echocardiography at different values of atrioventricular delay. Patients were considered to be responders if their cardiac outputs rose by 15%. In 7 patients meeting this criterion, the average increase in cardiac output was 27% (2.99 +/- 0.7 to 3.81 +/- 0.86 l/mn; p < 0.01); all had dilated cardiomyopathies with left bundle branch block and the optimal AV delay was 103 +/- 21 ms (80-140 ms); the duration of diastolic filling increased from 212 +/- 98 to 292 +/- 116 ms (p = 0.02). In the non-responding group (11 patients with an increase of cardiac output of only 3.6 +/- 0.09 to 3.9 +/- 0.92 l/mn; p < 0.01), the underlying disease process was mainly ischaemic. Two predictive factors of efficacy of dual-chamber pacing were identified: a short ventricular filling period (29 +/- 8% of the RR interval in the responders vs 44 +/- 9% in the non-responders; p < 0.01) and the presence of 1st degree atrioventricular block. Dual-chamber pacing could be a valuable method of increasing resting cardiac outputs in a selected group of patients with severe, refractory, cardiac failure.

  7. [Changes in the morphology of the normal left ventricle during the phases of isovolumic contraction and relaxation. Consequences on the calculation of the volume and cardiac output by cineangiocardiographic methods].

    Science.gov (United States)

    Nitenberg, A; Geschwind, H; Herreman, F

    1976-04-01

    It is well known that the left ventricular volume, as measured by the cineangiographic method, decreases during the phase of isometric contraction. What is more, the cardiac index and the ejection fraction measured by this method are definitely larger than those derived from dilution methods. These discrepancies can be explained by movements of the mitral valve during the phases of isometric contraction and relaxation. The systolic ejection volume (SEV) was measured by three different methods: 1. End-diastolic volume (EDV) -end-systolic volume (ESV) ; 2. EDV - pre-filling volume (PFV) ; 3. Pre-ejection volume (PEV) - ESV. It has emerged that the results given by the methods (2) and (3) correspond closely, and differ significantly from those given by method (1); they are also close to those obtained by the dilution method. This difference seems to arise from the fact that the movements of the mitral valve during the phase of isometric relaxation are diametrically opposite to those which occur during isometric contraction; thus, when the values EDV-ESV are used in the calculation of SEV, an overestimate is made because the mitral valve is not to be found in the same position within the ventricular cavity for both values.

  8. Cardiac Malpositions

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Shi Joon; Im, Chung Gie; Yeon, Kyung Mo; Hasn, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1979-06-15

    Cardiac Malposition refers to any position of the heart other than a left-sided heart in a situs solitus individual. Associated cardiac malformations are so complex that even angiocardiographic and autopsy studies may not afford an accurate information. Although the terms and classifications used to describe the internal cardiac anatomy and their arterial connections in cardiac malpositions differ and tend to be confusing, common agreement exists on the need for a segmental approach to diagnosis. Authors present 18 cases of cardiac malpositions in which cardiac catheterization and angiocardiography were done at the Department of Radiology, Seoul National University Hospital between 1971 and 1979. Authors analyzed the clinical, radiographic, operative and autopsy findings with the emphasis on the angiocardiographic findings. The results are as follows: 1. Among 18 cases with cardiac malpositions, 6 cases had dextrocardia with situs inversus, 9 cases had dextrocardia with situs solitus and 3 cases had levocardia with situs inversus. 2. There was no genuine exception to visceroatrial concordance rule. 3. Associated cardiac malpositions were variable and complex with a tendency of high association of transposition and double outlet varieties with dextrocardia in situs solitus and levocardia in situs inversus. Only one in 6 cases of dextrocardia with situs inversus had pure transposition. 4. In two cases associated pulmonary atresia was found at surgery which was not predicted by angiocardiography. 5. Because many of the associated complex lesions can be corrected surgically provided the diagnosis is accurate, the selective biplane angiocardiography with or without cineradiography is essential.

  9. Cardiac cameras.

    Science.gov (United States)

    Travin, Mark I

    2011-05-01

    Cardiac imaging with radiotracers plays an important role in patient evaluation, and the development of suitable imaging instruments has been crucial. While initially performed with the rectilinear scanner that slowly transmitted, in a row-by-row fashion, cardiac count distributions onto various printing media, the Anger scintillation camera allowed electronic determination of tracer energies and of the distribution of radioactive counts in 2D space. Increased sophistication of cardiac cameras and development of powerful computers to analyze, display, and quantify data has been essential to making radionuclide cardiac imaging a key component of the cardiac work-up. Newer processing algorithms and solid state cameras, fundamentally different from the Anger camera, show promise to provide higher counting efficiency and resolution, leading to better image quality, more patient comfort and potentially lower radiation exposure. While the focus has been on myocardial perfusion imaging with single-photon emission computed tomography, increased use of positron emission tomography is broadening the field to include molecular imaging of the myocardium and of the coronary vasculature. Further advances may require integrating cardiac nuclear cameras with other imaging devices, ie, hybrid imaging cameras. The goal is to image the heart and its physiological processes as accurately as possible, to prevent and cure disease processes.

  10. High-output heart failure in a newborn.

    Science.gov (United States)

    Mascarenhas, Maria Inês; Moniz, Marta; Ferreira, Sofia; Goulão, Augusto; Barroso, Rosalina

    2012-07-10

    High-output cardiac failure is rare in newborns. Emergent diagnosis and management of this pathology is crucial. We report the case of a child, currently 12-months old; obstetric background is non-contributory. Clinic observation on D1 was normal except for the presence of a systolic cardiac murmur; cardiological evaluation revealed mild ventricular dysfunction of the right ventricle. On the third day of life, she developed cardiac failure with gallop rhythm, hepatomegaly and a murmur in the anterior fontanel; an echocardiogram confirmed clinic aggravation with biventricular dysfunction and right cavities and superior vena cava dilatation. The cranial MRI confirmed the presence of a pial arteriovenous malformation (AVM) involving the anterior and middle cerebral arteries with an associated fronto-parietal ischaemic lesion. The infant underwent embolisations of AVM with successful flow reduction and cardiac failure improvement. The multidisciplinary follow-up showed no cardiac dysfunction or permanent lesions but confirmed a severe psycho-motor delay and left hemiparesia.

  11. Relationship between cardiac function and resting cerebral blood flow

    DEFF Research Database (Denmark)

    Henriksen, Otto M; Jensen, Lars T; Krabbe, Katja;

    2014-01-01

    Although both impaired cardiac function and reduced cerebral blood flow are associated with ageing, current knowledge of the influence of cardiac function on resting cerebral blood flow (CBF) is limited. The aim of this study was to investigate the potential effects of cardiac function on CBF. CBF...... and cardiac output were measured in 31 healthy subjects 50-75 years old using magnetic resonance imaging techniques. Mean values of CBF, cardiac output and cardiac index were 43.6 ml per 100 g min(-1), 5.5 l min(-1) and 2.7 l min(-1) m(-2), respectively, in males, and 53.4 ml per 100 g min(-1), 4.3 l min(-1......) and 2.4 l min(-1) m(-2), respectively, in females. No effects of cardiac output or cardiac index on CBF or structural signs of brain ageing were observed. However, fractional brain flow defined as the ratio of total brain flow to cardiac output was inversely correlated with cardiac index (r(2) = 0.22, P...

  12. Output hardcopy devices

    CERN Document Server

    Durbeck, Robert

    1988-01-01

    Output Hardcopy Devices provides a technical summary of computer output hardcopy devices such as plotters, computer output printers, and CRT generated hardcopy. Important related technical areas such as papers, ribbons and inks, color techniques, controllers, and character fonts are also covered. Emphasis is on techniques primarily associated with printing, as well as the plotting capabilities of printing devices that can be effectively used for computer graphics in addition to their various printing functions. Comprised of 19 chapters, this volume begins with an introduction to vector and ras

  13. 应用Swan-Ganz导管测定肺动脉高压犬模型肺循环阻力及心输出量的实验研究%Application of Swan-Ganz catheter to measure pulmonary vascular resistance and cardiac output of canine model with pulmonary arterial hypertension

    Institute of Scientific and Technical Information of China (English)

    林约瑟; 李淑娟; 李轩狄; 李运泉; 王慧深

    2015-01-01

    ObjectiveTo explore the value of Swan-Ganz catheter to measure pulmonary vascular resistance (PVR) and cardiac output (CO) of canine model with pulmonary arterial hypertension (PAH).MethodsSixteen Beagle dogs were randomly divided into two groups, the control group(n=8) and the pulmonary arterial hypertension group (n=8). Arterial blood was obtained to test arterial oxygen saturation. A Swan-Ganz catheter was advanced through the the right jugular vein way to the pulmonary artery and the pulmonary arterial pressure (PAP) were measured. Blood was obtained to test the pulmonary arterial oxygen saturation and plasma concentration of brain natriuretic peptide (BNP). Cardiac output and pulmonary vascular resistance were then calculated according to formula. The pulmonary arterial hypertension group were injected dehydromonocrataline 2.5 mg/kgto set up pulmonary arterial hypertension model. Hemodynamic measure was repeated after eight weeks.ResultsEight weeks after injection of dehydromonocrotaline, the pulmonary arterial systolic pressure, mean pulmonary arterial pressure of the pulmonary arterial hypertension group were significantly increased from (20.33±1.86) mmHg to (50.10±3.72) mmHg, (10.42±1.48) mmHg to (34.30±2.35) mmHg, the pulmonary arterial resistance, pulmonary vascular resistance were significantly increased from (1.10±0.24) Wood to (12.60±0.29) Wood, (2.34±0.33) Wood to (15.68±0.68) Wood, respectively, cardiac output was significantly decreased from (4.60±0.64) L/min to (2.30±0.35) L/min (P<0.05).ConclusionIt is an accurate, stable and repeatable method to apply Swan-Ganz catheter for measuring pulmonary vascular resistance and cardiac output in Beagle models with pulmonary arterial hypertension.%目的:探讨Swan-Ganz导管在肺动脉高压犬模型肺循环阻力及心输出量测定中的应用价值。方法16只比格犬随机分为2组,正常对照组(n=8)、肺动脉高压组(n=8)。穿刺动脉取血检测血氧饱和度。

  14. VMS forms Output Tables

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These output tables contain parsed and format validated data from the various VMS forms that are sent from any given vessel, while at sea, from the VMS devices on...

  15. Governmentally amplified output volatility

    Science.gov (United States)

    Funashima, Yoshito

    2016-11-01

    Predominant government behavior is decomposed by frequency into several periodic components: updating cycles of infrastructure, Kuznets cycles, fiscal policy over business cycles, and election cycles. Little is known, however, about the theoretical impact of such cyclical behavior in public finance on output fluctuations. Based on a standard neoclassical growth model, this study intends to examine the frequency at which public investment cycles are relevant to output fluctuations. We find an inverted U-shaped relationship between output volatility and length of cycle in public investment. This implies that periodic behavior in public investment at a certain frequency range can cause aggravated output resonance. Moreover, we present an empirical analysis to test the theoretical implication, using the U.S. data in the period from 1968 to 2015. The empirical results suggest that such resonance phenomena change from low to high frequency.

  16. Cardiac echinococcosis

    Directory of Open Access Journals (Sweden)

    Ivanović-Krstić Branislava A.

    2002-01-01

    Full Text Available Cardiac hydatid disease is rare. We report on an uncommon hydatid cyst localized in the right ventricular wall, right atrial wall tricuspid valve left atrium and pericard. A 33-year-old woman was treated for cough, fever and chest pain. Cardiac echocardiograpic examination revealed a round tumor (5.8 x 4 cm in the right ventricular free wall and two smaller cysts behind that tumor. There were cysts in right atrial wall and tricuspidal valve as well. Serologic tests for hydatidosis were positive. Computed tomography finding was consistent with diagnosis of hydatid cyst in lungs and right hylar part. Surgical treatment was rejected due to great risk of cardiac perforation. Medical treatment with albendazole was unsuccessful and the patient died due to systemic hydatid involvement of the lungs, liver and central nervous system.

  17. Cardiac Rehabilitation

    Science.gov (United States)

    ... your risk of future heart problems, and to improve your health and quality of life. Cardiac rehabilitation programs increase ... exercise routine at home or at a local gym. You may also continue to ... health concerns. Education about nutrition, lifestyle and weight loss ...

  18. Effects of Exercise Training on Haematology and Maximal Cardiac Output

    DEFF Research Database (Denmark)

    Bonne, Thomas Christian

    they can be a challenge in an anti-doping context. In study I nine individuals performed six weeks of endurance exercise. Intravascular volumes, Qmax and VO2max were measured before and after the training intervention. Any increases in BV were then restored by phlebotomy. After the training period, PV, RCV...... = 0.051) and time to complete 3000 m tended (P = 0.09) to increase in LHTH but not after sea level training. In study III haematological parameters were determined weekly three times before and four times after classical altitude and sea level training and ABP thresholds for [Hb], %ret, OFF...

  19. Phenylephrine Administration Increases Cardiac Output in Parasympathically Blocked Patients

    NARCIS (Netherlands)

    Kalmar, A.F.; Poterman, Marieke; Scheeren, Thomas

    2013-01-01

    Introduction:  Phenylephrine (PHE), a pure α1-agonist, is widely used to treat hypotension in anesthetized patients although controversy on its beneficial versus deleterious effects on blood flow and tissue perfusion is still vivid. Conventionally, PHE is considered to increase the arterial blood pr

  20. 脉搏指示连续心排血量监测技术在骨盆骨折合并失血性休克患者中的应用及护理%Nursing of pulse-indicated continuous cardiac output technique in pelvic fracture patients with hemorrhagic shock

    Institute of Scientific and Technical Information of China (English)

    赵文静; 程人佳; 张庆红; 赵文州

    2015-01-01

    Objective To investigate the clinical nursing methods of pulse-indicated con-tinuous cardiac output(PICCO)system in pelvic fracture patients with hemorrhagic shock.Methods The clinical data of 82 pelvic fracture patients with hemorrhagic shock treated in emergency inten-sive care unit (EICU)were retrospectively analyzed.Results In 82 patients,74 improved patients transferred to other departments or discharged and 8 patients died including 6 patients with acute re-nal failure.Conclusion Pelvic fracture patients with hemorrhagic shock using PICCO technology can accurately reflect the volume state.The PICCO management and PICCO safety is the key to en-sure successful treatment.%目的:探讨脉搏指示连续心排血量监测技术(PICCO)在骨盆骨折合并失血性休克患者中的应用及护理方法。方法对急诊重症监护室(EICU)收治的82例骨盆骨折合并失血性休克患者的临床及护理资料进行回顾性分析。结果82例患者中,病情好转转科或出院74例,死亡8例,其中并发急性肾衰竭6例。结论骨盆骨折合并失血性休克患者采用 PICCO技术能精准反映患者的容量状态,在 PICCO 的管理和观察中保证 PICCO 监测安全有效是救治成功的关键。

  1. Pulse Indicator Continuous Cardiac Output for Hemodynamics Monitoring in Patients with Septic Shock%脉搏指示连续心排血量监测(PiCCO)在脓毒症休克患者血流动力学监测中的临床价值

    Institute of Scientific and Technical Information of China (English)

    伊敏; 么改琦; 朱曦; 郭向阳

    2013-01-01

    目的 探讨脉搏指示连续心排血量监测技术(pulse indicator continuous cardiac output,PiCCO)在脓毒症休克患者血流动力学监测中的临床价值. 方法 2012年1~8月,前瞻性队列研究比较常规监测(n=12)与PiCCO监测(n=19)脓毒症休克患者的血流动力学,应用PiCCO监测指导脓毒症休克患者的液体复苏、血管收缩药和正性肌力药物的使用. 结果 2组脓毒症休克患者性别、年龄、原发病、既往病史、多器官功能不全综合征(MODS)的发生和发生MODS器官数、急性生理学及慢性健康状况评分系统(APACHE)Ⅱ、脓毒症相关器官衰竭评分(SOFA)、应用去甲肾上腺素剂量和入ICU后7天总的输液量差异均无显著性,PiCCO组初始平均动脉压(MAP)明显低于常规组[(52.00±5.00)mm Hg vs.(59.58±3.42)mm Hg,t=4.603,P=0.000],而对于PiCCO组存在心功能损害的患者应用正性肌力药治疗后达到与常规组相同的MAP达标值[(68.00±2.43)mm Hg vs.(68.58±2.88)mm Hg,t=0.607,P=0.549],2组MAP达标值差异无显著性. 结论 在PiCCO监测指导下,可以对于存在心功能损害的患者应用正性肌力药物,而不是仅应用血管收缩药升高血压.%Objective To investigate the clinical value of pulse indicator continuous cardiac output ( PiCCO) in hemodynamics monitoring for patients with septic shock. Methods A prospective cohort study comparing routine hemodynamics monitoring (n = 12) and PiCCO (n = 19) for patients with septic shock were carried out from January to August 2012. The PiCCO monitor provided a continuous assessment of fluid resuscitation, vasopressors and inotropes infusion in septic shock patients. Results There were no significant difference between the two groups in sex, age, etiology of critical illness, medical history, incidence of MODS, number of MODS involved organ, APACHE Ⅱ and SOFA scores, usage of noradrenaline, and total volume of fluid infusion in a week. In the PiCCO group, the original MAP

  2. Cardiac Calcification

    Directory of Open Access Journals (Sweden)

    Morteza Joorabian

    2011-05-01

    Full Text Available There is a spectrum of different types of cardiac"ncalcifications with the importance and significance"nof each type of cardiac calcification, especially"ncoronary artery calcification. Radiologic detection of"ncalcifications within the heart is quite common. The"namount of coronary artery calcification correlates"nwith the severity of coronary artery disease (CAD."nCalcification of the aortic or mitral valve may indicate"nhemodynamically significant valvular stenosis."nMyocardial calcification is a sign of prior infarction,"nwhile pericardial calcification is strongly associated"nwith constrictive pericarditis. A spectrum of different"ntypes of cardiac calcifications (linear, annular,"ncurvilinear,... could be seen in chest radiography and"nother imaging modalities. So a carful inspection for"ndetection and reorganization of these calcifications"nshould be necessary. Numerous modalities exist for"nidentifying coronary calcification, including plain"nradiography, fluoroscopy, intravascular ultrasound,"nMRI, echocardiography, and conventional, helical and"nelectron-beam CT (EBCT. Coronary calcifications"ndetected on EBCT or helical CT can be quantifie,"nand a total calcification score (Cardiac Calcification"nScoring may be calculated. In an asymptomatic"npopulation and/or patients with concomitant risk"nfactors like diabetes mellitus, determination of the"npresence of coronary calcifications identifies the"npatients at risk for future myocardial infarction and"ncoronary artery disease. In patients without coronary"ncalcifications, future cardiovascular events could"nbe excluded. Therefore, detecting and recognizing"ncalcification related to the heart on chest radiography"nand other imaging modalities such as fluoroscopy, CT"nand echocardiography may have important clinical"nimplications.

  3. INFLUENCE OF MIMIC CARDIAC RATE ON HYDRODYNAMICS OF DIFFERENT MECHANICAL PROSTHETIC CARDIAC VALVES IN VITRO

    Institute of Scientific and Technical Information of China (English)

    Yin-ping Chu; Jin-lian Cheng; Ru-kun Chen; Yu-bo Fan; Fang Pu

    2005-01-01

    Objective To assess the influence of mimic cardiac rate on hydrodynamics of different mechanical prosthetic cardiac valves.Methods US-made CarboMedics bileaflet valve, China-made Jiuling bileaflet valve and C-L tilting disc valve were tested via a pulsatile flow simulator in the aortic position. Testing conditions were set at mimic cardiac rates of 55 bpm, 75 bpm, 100bpm with a constant mimic cardiac output of 4 L/min. The mean pressure differences (△P), leakage volumes (LEV) and closing volumes (CLV) across each valve, and effective orifice areas (EOA) were analyzed.Results Within physiological range, △p, LEV, and CLV decreased as mimic cardiac rate increased, with a large extent of variance. EOA increased along with an increase in mimic cardiac rate. It was a different response in terms of cardiac rate alteration for different types of mechanical prosthetic cardiac valves.Conclusion Mimic cardiac rate change affects hydrodynamics of mechanical prosthetic cardiac valves. Within physiological range, the hydrodynamic of prosthetic bileaflet valve is better than that of tilting disc valve.

  4. 脉搏指示连续心排血量监测技术救治重症胰腺炎并发急性呼吸窘迫综合征患儿二例%Pulse indicator continuous cardiac output measurement-guided treatment aids two pediatric patients with severe acute pancreatitis complicated with acute respiratory distress syndrome

    Institute of Scientific and Technical Information of China (English)

    颜卫源; 王丽杰

    2014-01-01

    Objective To evaluate the clinical value of the pulse indicator continuous cardiac output (PiCCO) system in patients with severe acute pancreatitis (SAP) complicated with acute respiratory distress syndrome (ARDS).Method Two cases of SAP with ARDS were monitored using PiCCO during comprehensive management in the Pediatric Intensive Care Unit (PICU) of Shengjing Hospital,China Medical University.To guide fluid management,the cardiac index (CI) was measured to assess cardiac function,the global end-diastolic volume index (GEDVI) was used to evaluate cardiac preload,and the extravascular lung water index (EVLWI) was used to evaluate the pulmonary edema.Result Case 1 was diagnosed with type L2 acute lymphoblastic leukemia (intermediate risk) and received the sixth maintenance phases of chemotherapy this time.After a 1-week dosage of chemotherapeutic drugs (pegaspargase and mitoxantrone),he suffered SAP combined with ARDS.Except comprehensive treatment (life supporting,antibiotic,etc.) and applying continuous veno-venous hemodiafiltration (CVVHDF) to remove inflammatory mediators.PiCCO monitor was utilized to guide fluid management.During the early stage of PiCCO monitoring,the patient showed no significant manifestations of pulmonary edema in the bedside chest X-ray (bedside ultrasound showed left pleural effusion),and had an oxygenation index 223 mmHg (1 mmHg =0.133 kPa),GEDVI 450 ml/m2,and ELVWI 7 ml/kg.We increased cardiac output to increase tissue perfusion and dehydration speed of CVVHDF was set at 70 ml/h.Two hours later,GEDVI significantly increased to 600 ml/m2 and ELVWI significantly increased to 10 ml/kg,the oxygenation index declined to 155 mmHg,the bedside chest X-ray showed a significant decrease of permeability (right lung) and PEEP was adjusted to 5 cmH2O (1 cmH2O =0.098 kPa),indicating circulating overload.ARDS subsequently occurred,upon which the fluid infusion was halted,the dehydration rate of CVVHDF raised (adjusted to 100-200 ml/h).On day 3 in the

  5. 脓毒性休克患者血浆脑钠肽与 PiCCO 相关指标的关系%The correlation between plasma brain natriuretic peptide (BNP)levels and parameters of pulse -indicated continuous cardiac output(PiCCO)in patients with septic shock

    Institute of Scientific and Technical Information of China (English)

    吴翔; 陶飞; 胡桂芳; 邓烈华; 姚华国

    2016-01-01

    Objective To investigate the relationship between plasma brain natriuretic peptide (BNP)levels and the monito-ring indicators of pulse -indicated continuous cardiac output (PiCCO)in patients with sepstic shock.Methods 48 patients with septic shock according to the criteria of sepsis set by SC-CN /ESICM/ACCP /ATS /SIS were selected.Clinical and laboratory data including BNP were collected on the 1 d,3rd and 5 th day after admittion.The hemodynamics of the patients was monitored using PiCCO technology,and the heart function indexs were recorded,incluing CI,CFI,GEF and dP /dPmax.Acute Physiology and Chronic Health Evaluation (APACHEⅡ)and Sepsis -related Organ Failure Assessment (SOFA)score were determined.The correlation between BNP levels and the above indexs was analyzed.Results The levels of plasma BNP had negative correlation with CI,CFI,GEF (r =-0.339, -0.250, -0.241 ,P 0.05 ).The levels of plasma BNP had significant positive correlation with APACHEII scores and SOFA scores (r =0.509,0.565 ,P <0.05 ). Conclusion The cardiac function could not be reflected by BNP levels in septic shock patients.Plasma BNP levels can re-flect the severity of septic shock in certain degree,and might be considered as a valuable prognostic factor for patients with septic shock.%目的:通过监测脓毒性休克患者血浆脑钠肽(BNP)水平以及脉搏指示连续心排血量(PiCCO)相关指标的变化,探讨脓毒性休克患者脑钠肽水平与心功能的关系。方法选取48例脓毒性休克患者为研究对象,检测患者入 ICU第1、3、5天血浆 BNP 水平,通过 PiCCO 技术对患者进行血流动力学监测,记录反应心功能指标的 CI、CFI、GEF 和 dP/dP-max,并进行 APACHEⅡ、SOFA 评分,分析 BNP 与上述指标的相关性。结果脓毒性休克患者血浆 BNP 水平与 CI 、CFI、GE 呈负相关(r =-0.339、-0.25、-0.241,P <0.05),与 dP/dPmax 无显著相关性(P >0.05

  6. 体外膜氧合成功救治新生儿心脏术后严重低心排综合征一例%Extracorporeal membrane oxygenation treatment of a neonate with severe low cardiac output syndrome following open heart surgery

    Institute of Scientific and Technical Information of China (English)

    林茹; 谈林华; 张泽伟; 孙眉月; 杜立中

    2008-01-01

    目的 总结ECMO救治新生儿心脏术后严重低心排的成功经验.方法 2007年7月18日我们对一例患先天性大动脉转位(TGA)合并房间隔缺损(ASD)、动脉导管未闭(PDA)2.8 kg出生6 d的新生儿,进行了大动脉调转术(arteries switch)、ASD修补、PDA结扎术,畸形矫正后出现严重低心排综合征,低血压[<39/30 mm Hg(1 mm Hg=0.133 kPa)]、高乳酸血症(Lac 8.8 mmol/L)、高左房压(LAP>20 mm Hg)、血性痰、少尿[<1 ml/(kg·h)],由于转流时间较长(263 min)且难以脱离体外循环,常规治疗无效后接V-A ECMO进行心肺辅助.结果 经87h ECMO辅助后,左心功能明显恢复,患儿顺利脱离ECMO,ECMO第1天LVEF 20%,第2天34%,第3天43%;ECMO第1天CKMB 41 μ/L,第2天恢复正常.脱离ECMO后,在较高浓度血管活性药支持下[肾上腺素0.2 μg/(kg·min),多巴胺/多巴酚丁胺8 μg/(kg·min),米力农0.56 μg/(kg·min)],循环基本稳定.ECMO撤离后第4天,关闭胸部切口.ECMO撤离后第22天,撤离呼吸机,术后30 d撤离血管活性药.术后58 d康复出院.出院时心肺、肝肾功能正常,神志清醒,四肢肌张力和运动正常.整个病程中多次头颅超声检查均未发现脑出血、梗死等病灶.ECMO并发症:(1)肺出血;(2)伤口出血和心包填塞;(3)溶血;(4)高胆红素血症.结论 ECMO对抢救新生儿心脏术后严重心功能不全有良好的疗效.%Objective To summarize the experience of extracorporeal membrane oxygenation (ECMO)to rescue a neonate with severe low cardiac output syndrome following open heart surgery.Methods The patient was a male,2 d,2.8 kg,G3P2 full-term neonate with gestational age 40 weeks,born by Cesarean-section with Apgar score of 10 at 1 min.He was admitted due to severe dyspnea with oxygen desaturation and heart murmur on the second day after birth.Physical examination showed clear consciousness,cyanosis,dyspnea,RR 70 bpm and a grade Ⅱ/6 heart murmur.Bp was 56/45 mm Hg (1 mm Hg=0.133 kPa)and SpO2 around 65

  7. Pulse Indicator Continuous Cardiac Output for Hemodynamics Monitoring in Patients with Septic Shock%脉搏指示连续心排血量监测(PiCCO)在脓毒症休克患者血流动力学监测中的临床价值

    Institute of Scientific and Technical Information of China (English)

    陈涛

    2015-01-01

    Objective To observe and analyze patients with septic shock pulse wave indicates continuous cardiac output monitoring (Picco) clinical value, to provide a reference for future clinical use. Methods January 2013—2014 in March during outpatient sep-sis patients admitted to 40 cases for the study, depending on the admission of hemodynamic monitoring methods divided into two groups, the study group and the control group 20 cases. Two were used for routine monitoring (control group), Picco monitoring (study group) to guide clinical treatment (fluid resuscitation, inotropic drugs, vasoconstrictor drugs, etc.). Results The mean arterial pressure in the two groups of patients after treatment of the initial value and compare, P 0.05). Conclusion Picco be monitored in patients with septic shock hemodynamic parameters with good results, it is worth further study in late.%目的:观察脓毒症休克患者采用脉波指示连续心排血量监测(PiCCO)的效果,并分析其临床应用价值。方法将医院2012年1月—2014年3月期间门诊收入的脓毒症50例患者选为研究对象,按照患者就诊时血动力指标的监测方式不同分成两组:研究组25例,对照组25例。两组分别采用常规监测(对照组)、PiCCO监测(研究组)指导临床治疗(液体复苏、正性肌力药物、血管收缩药物等)。结果两组患者的平均动脉压在初始值比较(P<0.01);研究组患者入院3 d内不同时点GEDI、PPV、SVV检测值比较,组间差异有统计学意义(P<0.05)。组间在去甲肾上腺素和就诊1周输液量比较,差异无统计学意义(P>0.05)。结论脓毒症休克患者予以PiCCO监测血流动力学指标具有良好效果,值得在后期进一步研究。

  8. Improvement of cardiac function after kidney transplantation with dilated cardiomyopathy and long dialysis vintage.

    Science.gov (United States)

    Mimura, Imari; Kawarazaki, Hiroo; Momose, Toshimitsu; Shibagaki, Yugo; Fujita, Toshiro

    2009-12-01

    Patients with long dialysis vintage have low cardiac output for various reasons. Although kidney transplantation is known to improve cardiac mortality, patients are sometimes evaluated as contraindicated for transplantation because of cardiac risk. We successfully performed kidney transplantation for a patient with a long dialysis vintage and dilated cardiomyopathy. Sequential (123)I-metaiodobenzylguanidine ((123)I-MIBG) scintigraphy suggested that amelioration of uraemia improved cardiac function. Kidney transplantation for patients with severely impaired cardiac function is safe and effective under careful perioperative monitoring irrespective of dialysis vintage. Sequential (123)I-MIBG scintigraphy can be used as an evaluation tool for the improvement in cardiac function.

  9. A new nonlinear output tracking controller via output-feedback

    Institute of Scientific and Technical Information of China (English)

    Yun ZHANG; Yungang LIU; Yuqin DING

    2006-01-01

    In this paper, the output tracking control is investigated for a class of nonlinear systems when only output is available for feedback. Based on the multivariable analog of circle criterion, an observer is first introduced. Then, the observer-based output tracking controller is constructively designed by using the integral backstepping approach together with completing square. It is shown that, under relatively mild conditions, all the closed-loop signals are uniformly bounded.Meanwhile the system output asymptotically tracks the desired output. A simulation example is given to illustrate the effectiveness of the theoretical results.

  10. Cardiac MRI in Athletes

    NARCIS (Netherlands)

    Luijkx, T.

    2012-01-01

    Cardiac magnetic resonance imaging (CMR) is often used in athletes to image cardiac anatomy and function and is increasingly requested in the context of screening for pathology that can cause sudden cardiac death (SCD). In this thesis, patterns of cardiac adaptation to sports are investigated with C

  11. Troponin not just a simple cardiac marker: prognostic significance of cardiac troponin

    Institute of Scientific and Technical Information of China (English)

    Benny Mulyanto Setiadi; LEI Han; CHANG Jing

    2009-01-01

    Objective The object of this study was to review the role of cardiac troponin as a prognostic factor in acute coronary syndrome patients of varying circumstances.Data sources The data used in this review were obtained mainly from the studies of cardiac troponin reported in pubmed from 1981 to 2006.Study selection Relevant articles on studies of cardiac troponin were selected.Results Elevated cardiac troponin in patients with ST elevation and non ST elevation myocardial infarction was associated with adverse outcomes, including a higher incidence of congestive heart failure, shock, and death. Patients with elevated cardiac troponin value seemed to benefit more from invasive strategies including a percutaneous coronary intervention and bypass surgery, but elevated cardiac troponin was also correlated with adverse outcomes, including a higher degree of failure, shock, and mortality in patients undergoing percutaneous coronary intervention; a higher degree of perioperative myocardial infarction, low cardiac output syndrome, cardiopulmonary resuscitation, and new-onset ventricular arrhythmia in patients undergoing bypass surgery were also observed. Elevated troponin after a percutaneous coronary intervention seemed to be associated with short-term adverse outcomes rather than long-term adverse outcomes, unless the elevation of the troponin post percutaneous coronary intervention was quite high (about 5 times above normal). On the contrary, elevated cardiac troponin after bypass surgery was more confusing to analyze since it happened in almost all patients. Furthermore, differences in cutoff values and time measurements in some studies add more confusion; thus, further research is warranted.Conclusions The prognostic value of cardiac troponin is demonstrated in almost all acute coronary syndrome patients. In addition to its high sensitivity and specificity, the prognostic value of cardiac troponin is another reason to make it the "golden cardiac marker' of this time.

  12. Débito cardíaco e fração de ejeção fetal por meio do spatio-temporal image correlation (STIC: comparação entre fetos masculinos e femininos Fetal cardiac output and ejection fraction by spatio-temporal image correlation (STIC: comparison between male and female fetuses

    Directory of Open Access Journals (Sweden)

    Christiane Simioni

    2012-06-01

    Full Text Available OBJETIVO: Comparar do débito cardíaco (DC e a fração de ejeção (FE do coração de fetos masculinos e femininos obtidos por meio da ultrassonografia tridimensional, utilizando o spatio-temporal image correlation (STIC. MÉTODOS: Realizou-se um estudo de corte transversal com 216 fetos normais, entre 20 a 34 semanas de gestação, sendo 108 masculinos e 108 femininos. Os volumes ventriculares no final da sístole e diástole foram obtidos por meio do STIC, sendo as avaliações volumétricas realizadas pelo virtual organ computer-aided analysis (VOCAL com rotação de 30º. Para o cálculo do DC utilizou-se a fórmula: DC= volume sistólico/frequência cardíaca fetal, enquanto que para a FE utilizou-se a fórmula: FE= volume sistólico/volume diastólico final. O DC (combinado, feminino e masculino e a FE (masculina e feminina foram comparadas utilizando-se o teste t não pareado e ANCOVA. Foram criados gráficos de dispersão com os percentis 5, 50 e 95. RESULTADOS: A média do DC combinado, DC direito, DC esquerdo, FE direita e FE esquerda, para feminino e masculino, foram 240,07 mL/min; 122,67 mL/min; 123,40 mL/min; 72,84%; 67,22%; 270,56 mL/min; 139,22 mL/min; 131,34 mL/min; 70,73% e 64,76%, respectivamente; sem diferença estatística (P> 0,05. CONCLUSÕES: O DC e a FE fetal obtidos por meio da ultrassonografia tridimensional (STIC não apresentaram diferença significativa em relação ao gênero.OBJECTIVE: To compare the cardiac output (CO and ejection fraction (EF of the heart of male and female fetuses obtained by 3D-ultrasonography using spatio-temporal image correlation (STIC. METHODS: We conducted a cross-sectional study with 216 normal fetuses, between 20 and 34 weeks of gestation, 108 male and 108 female. Ventricular volumes at the end of systole and diastole were obtained by STIC, and the volumetric assessments performed by the virtual organ computer-aided analysis (VOCAL rotated 30º. To calculate the DC used the formula

  13. Application of pulse indicator continuous cardiac output monitor in the fluid resuscitation therapy in elderly patients with septic shock%脉搏指示连续心排血量监护仪在老年感染性休克液体复苏治疗中的应用

    Institute of Scientific and Technical Information of China (English)

    林华; 郑瑞强; 吴晓燕; 於江泉; 卢年芳; 邵俊; 王海霞

    2012-01-01

    Objective To investigate the guiding significance of pulse indicator continuous cardiac output(PICCO) for the fluid resuscitation in elderly patients with septic shock. Methods Twenty-four elderly patients with septic shock were divided into observation group and control group,twelve cases in each group. The patients in observation group were treated with fluid resuscitation under the guidance of PICCO monitor, while the patients in control group were treated with fluid resuscitation under the guidance of monitoring central venous pressure, then the curative effect was compared between the two groups. Results On the first day of treatment, there was no statistical difference in the blood cell and neutrophil counts, mixed venous oxygen saturation ( SvO2) ,the levels of procalcitonin ( PCT) and lactic acid (LA) between the two groups (P >0. 05). On the second and third days of treatment, the white blood cell, neutrophil counts and the levels of LA and PCT in observation group were significantly lower than those in control group(P <0. 05) ,but SvO2 was significantly higher( P < 0. 05). Compared with control group,the mechanical ventilation time was significantly shorter(P <0. 05) , and the case fatality within 28 days was lower in observation group( P < 0.05 ). Conclusion PICCO monitor has important guiding significance in the treatment of fluid resuscitation in elderly patients with septic shock,which can significantly improve blood gas analysis index,shorten the mechanical ventilation time and reduce mortality.%目的 探讨脉搏指示连续心排血量(PICCO)监测技术对老年感染性休克液体复苏治疗的指导意义.方法 24例老年感染性休克患者分为观察组和对照组,每组12例.观察组患者在PICCO监护仪监测指导下补液治疗,对照组患者在监测中心静脉压指导下补液治疗;观察比较2组治疗效果.结果 治疗第1天,2组患者白细胞、中性粒细胞计数、混合静脉血氧饱和度(SvO2)、血降

  14. Dynamic NMR cardiac imaging in a piglet

    Energy Technology Data Exchange (ETDEWEB)

    Doyle, M.; Rzedzian, R.; Mansfield, P. (Nottingham Univ. (UK). Dept. of Physics); Coupland, R.E. (Nottingham Univ. (UK). Queen' s Medical Centre)

    1983-12-01

    NMR echo-planar imaging (EPI) has been used in a real-time mode to visualise the thorax of a live piglet. Moving pictures are available on an immediate image display system which demonstrates dynamic cardiac function. Frame rates vary from one per cardiac cycle in a prospective stroboscopic mode with immediate visual output to a maximum of 10 frames per second yielding up to six looks in one piglet heart cycle, but using a visual playback mode. A completely new system has been used to obtain these images, features of which include a probe assembly with 22 cm access and an AP400 array processor for real-time data processing.

  15. Serial Input Output

    Energy Technology Data Exchange (ETDEWEB)

    Waite, Anthony; /SLAC

    2011-09-07

    Serial Input/Output (SIO) is designed to be a long term storage format of a sophistication somewhere between simple ASCII files and the techniques provided by inter alia Objectivity and Root. The former tend to be low density, information lossy (floating point numbers lose precision) and inflexible. The latter require abstract descriptions of the data with all that that implies in terms of extra complexity. The basic building blocks of SIO are streams, records and blocks. Streams provide the connections between the program and files. The user can define an arbitrary list of streams as required. A given stream must be opened for either reading or writing. SIO does not support read/write streams. If a stream is closed during the execution of a program, it can be reopened in either read or write mode to the same or a different file. Records represent a coherent grouping of data. Records consist of a collection of blocks (see next paragraph). The user can define a variety of records (headers, events, error logs, etc.) and request that any of them be written to any stream. When SIO reads a file, it first decodes the record name and if that record has been defined and unpacking has been requested for it, SIO proceeds to unpack the blocks. Blocks are user provided objects which do the real work of reading/writing the data. The user is responsible for writing the code for these blocks and for identifying these blocks to SIO at run time. To write a collection of blocks, the user must first connect them to a record. The record can then be written to a stream as described above. Note that the same block can be connected to many different records. When SIO reads a record, it scans through the blocks written and calls the corresponding block object (if it has been defined) to decode it. Undefined blocks are skipped. Each of these categories (streams, records and blocks) have some characteristics in common. Every stream, record and block has a name with the condition that each

  16. Inverter communications using output signal

    Energy Technology Data Exchange (ETDEWEB)

    Chapman, Patrick L.

    2017-02-07

    Technologies for communicating information from an inverter configured for the conversion of direct current (DC) power generated from an alternative source to alternating current (AC) power are disclosed. The technologies include determining information to be transmitted from the inverter over a power line cable connected to the inverter and controlling the operation of an output converter of the inverter as a function of the information to be transmitted to cause the output converter to generate an output waveform having the information modulated thereon.

  17. Nonlinear input-output systems

    Science.gov (United States)

    Hunt, L. R.; Luksic, Mladen; Su, Renjeng

    1987-01-01

    Necessary and sufficient conditions that the nonlinear system dot-x = f(x) + ug(x) and y = h(x) be locally feedback equivalent to the controllable linear system dot-xi = A xi + bv and y = C xi having linear output are found. Only the single input and single output case is considered, however, the results generalize to multi-input and multi-output systems.

  18. Output Model of Steel Plant

    Institute of Scientific and Technical Information of China (English)

    ZHANG Long-qiang; TIAN Nai-yuan; ZHANG Jin; XU An-jun

    2008-01-01

    Based on the requirement of compactivity, continuity, and high efficiency, and taking full advantage of cushion capability of flexible parts such as external refining in new generation steel plant, an output model of steel plant was established in terms of matching between BOF and caster. Using this model, the BOF nominal capacity is selected, the caster output and equipment amount are computed, and then the steel plant output is computed.

  19. 脉搏指示连续心排血量技术对压力与容量控制模式机械通气容量参数的影响%Influence of pulse indicator continuous cardiac output in monitoring on the volume parameters of different tidal volume under pressure control ventilation mode and volume-controlled ventilation mode in sheep

    Institute of Scientific and Technical Information of China (English)

    李军; 高心晶; 高艳颖; 卫俊涛; 秦英智

    2010-01-01

    Objective To compare the influence of pulse indicator continuous cardiac output(PiCCO)in monitoring tidal volume(V_T)under pressure control ventilation mode and volume-controlled ventilation mode in sheep.Methods After anesthesia and tracheotomy,5 sheep,which were apneic and receiving mechanical ventilation.Twenty minutes later,central venous pressure(CVP)and cardiac function were monitored with different selected V_T levels of 6,10,15,20 ml/kg under bi-level positive airway pressure (BiPAP)mode by changing the pressure of inspiration,or under the synchronized intermittent mandatory ventilation(SIMV)mode with the same ventilation conditions.Results In both modes,the increase in V_T led to an decrease of cardiac index(CI)and intrathoracic blood volume index(ITBVI),reaching a statistically significant difference at 15 ml/kg[SIMV mode:CI(3.94±1.03)L·min~(-1)·m~(-2),ITBVI (707±105)ml/m2;BiPAP mode:CI(4.11±1.11)L·min-1±m-2,ITBVI(715±122)ml/m2]and 20 ml/kg[SIMV mode:CI(3.87±1.04)L·min~(-1)·m~(-2),ITBVI(705±116)ml/m2;BiPAP mode:CI (3.64±0.96)L·min~(-1)·m~(-2),ITBVI(694±114)ml/m2]compared with 6 ml/kg[SIMV mode:CI (4.96±1.58)L·min~(-1)·m~(-2),ITBVI(811±169)ml/m2;BiPAP mode:CI(5.67±1.96)L·min~(-1)·m~(-2),ITBVI(8234-182)ml/m~2,all P<0.05];an increase in systemic vascular resistance index(SVRI)and mean airway pressure(Pmean)at 15 ml/kg[SIMV mode:SVRI(237.64±6.2)kPa·s~(-1)·L~(-1),Pmean(14.0±3.2)cm H2O(1 cm H2O=0.098 kPa);BiPAP mode:SVRI(230.8±32.9)kPa·s~(-1)·L~(-1),Pmean(13.0±2.2)cm H_2O]and 20 ml/kg[SIMV mode:SVRI(253.1±76.7)kPa·s~(-1)·L~(-1),Pmean(18.2±4.8)cm H_2O;BiPAP mode:SVRI(246.7±48.8)kPa·s~(-1)·L~(-1),Pmean(16.8±3.3)cm H_2O]compared with 6 ml/kg[SIMV mode:SVRI(184.8±47.5)kPa·s~(-1)·L~(-1);Pmean(8.8±1.6)cm H_2O;BiPAP mode:SVRI(184.5±51.5)kPa·s~(-1)·L~(-1),Pmean(8.6±0.5)cm H_2O,all P<0.05];but there was no significant effects on CVP,heart rate(HR),mean blood pressure(MBP).There was no significant difference of CI

  20. In Vitro Study of Influence of Mimic Cardiac Rate on Hydrodynamics of the Different Mechanical Cardiac Valve Prostheses

    Institute of Scientific and Technical Information of China (English)

    CHU Yin-ping; CHENG Jin-lian; CHEN Ru-kun; FAN Yu-bo; PU Fang

    2005-01-01

    Objective:To assess the influence of mimic cardiac rate on hydrodynamics of the different mechanical prosthetic cardiac valves. Methods: US-made CarboMedics bileaflet valve and China-made Jiuling bileaflet valve and C-L tilting disc valve have been tested in a pulsatile flow simulator in the aortic position. The testing condition was set at the mimic cardiac rate of 55 beats/min,75 beats/min,100beats/min and a constant mimic cardiac output of 4L/min. The mean pressure differences (△P) ,leakage volumes (LEV) and closing volumes (CLV) across each valve,and the effective orifice areas(EOA) have been analyzed. Results:Within the range of physiology,the △P,LEV and CLV were falling as the increasing of mimic cardiac rate,and the extent of variance was larger. The EOA was increasing with the increase of the mimic cardiac rate. It is a different response as the altering of the cardiac rate for the different type of the mechanical prosthetic cardiac valves.Conclusions:The change of the mimic cardiac rate can affect the hydrodynamics of the mechanical prosthetic cardiac valves. The hydrodynamics of the bileaflet valve prosthesis is better than the tilting disc valve.

  1. Cardiac tamponade (image)

    Science.gov (United States)

    Cardiac tamponade is a condition involving compression of the heart caused by blood or fluid accumulation in the space ... they cannot adequately fill or pump blood. Cardiac tamponade is an emergency condition that requires hospitalization.

  2. What Is Cardiac Rehabilitation?

    Science.gov (United States)

    ANSWERS by heart Treatments + Tests What Is Cardiac Rehabilitation? A cardiac rehabilitation (rehab) program takes place in a hospital or ... special help in making lifestyle changes. During your rehabilitation program you’ll… • Have a medical evaluation to ...

  3. Neurons within the same network independently achieve conserved output by differentially balancing variable conductance magnitudes.

    Science.gov (United States)

    Ransdell, Joseph L; Nair, Satish S; Schulz, David J

    2013-06-12

    Biological and theoretical evidence suggest that individual neurons may achieve similar outputs by differentially balancing variable underlying ionic conductances. Despite the substantial amount of data consistent with this idea, a direct biological demonstration that cells with conserved output, particularly within the same network, achieve these outputs via different solutions has been difficult to achieve. Here we demonstrate definitively that neurons from native neural networks with highly similar output achieve this conserved output by differentially tuning underlying conductance magnitudes. Multiple motor neurons of the crab (Cancer borealis) cardiac ganglion have highly conserved output within a preparation, despite showing a 2-4-fold range of conductance magnitudes. By blocking subsets of these currents, we demonstrate that the remaining conductances become unbalanced, causing disparate output as a result. Therefore, as strategies to understand neuronal excitability become increasingly sophisticated, it is important that such variability in excitability of neurons, even among those within the same individual, is taken into account.

  4. Collector-Output Analysis Program

    Science.gov (United States)

    Glandorf, D. R.; Phillips, Robert F., II

    1986-01-01

    Collector-Output Analysis Program (COAP) programmer's aid for analyzing output produced by UNIVAC collector (MAP processor). COAP developed to aid in design of segmentation structures for programs with large memory requirements and numerous elements but of value in understanding relationships among components of any program. Crossreference indexes and supplemental information produced. COAP written in FORTRAN 77.

  5. Cardiac sodium channelopathies

    NARCIS (Netherlands)

    Amin, A.S.; Asghari-Roodsari, A.; Tan, H.L.

    2010-01-01

    Cardiac sodium channel are protein complexes that are expressed in the sarcolemma of cardiomyocytes to carry a large inward depolarizing current (I-Na) during phase 0 of the cardiac action potential. The importance of I-Na for normal cardiac electrical activity is reflected by the high incidence of

  6. Multi-output differential technologies

    Science.gov (United States)

    Bidare, Srinivas R.

    1997-01-01

    A differential is a very old and proven mechanical device that allows a single input to be split into two outputs having equal torque irrespective of the output speeds. A standard differential is capable of providing only two outputs from a single input. A recently patented multi-output differential technology known as `Plural-Output Differential' allows a single input to be split into many outputs. This new technology is the outcome of a systematic study of complex gear trains (Bidare 1992). The unique feature of a differential (equal torque at different speeds) can be applied to simplify the construction and operation of many complex mechanical devices that require equal torque's or forces at multiple outputs. It is now possible to design a mechanical hand with three or more fingers with equal torque. Since these finger are powered via a differential they are `mechanically intelligent'. A prototype device is operational and has been used to demonstrate the utility and flexibility of the design. In this paper we shall review two devices that utilize the new technology resulting in increased performance, robustness with reduced complexity and cost.

  7. Correlation between radius and respiration variation of inferior vena cava and hemodynamicmonitoring values of pulse-indicated continuous cardiac output(PiCCO)in septic shock pigs%脓毒症休克猪下腔静脉管径及呼吸变异指数与血流动力学的关系

    Institute of Scientific and Technical Information of China (English)

    王海峰; 刘笑雷; 陆海涛; 齐志伟; 闫圣涛; 顾承东; 张国强

    2012-01-01

    目的 探讨脓毒症休克时下腔静脉管径及呼吸变异指数与脉搏指示连续心排出量(PiCCO)血流动力学指标的关系.方法 取8只幼年猪,颈内静脉推注大肠杆菌内毒素(LPS,100tμg/kg)制作脓毒症休克模型,出模后予生理盐水进行液体复苏.分别在动物模型制作前、休克时、液体复苏1h及6h时点超声探测下腔静脉最大径(IVCmax)、最小径(IVCmin)并计算呼吸变异指数(IVCrvi),同时记录PiCCO血流动力学指标,包括:胸廓内血容量(ITBV)、全心舒张末容积(GEDV)、每搏输出量变异指数(SVV)和心脏指数(CI).采LSD-t检验比较液体复苏前后IVCmax、IVCmin、IVCrvi及PiCCO血流动力学指标的变化;采用Pearson相关性分析了解IVCmax、IVCmin及IVCrvi与PiCCO血流动力学指标的相关性.结果 液体复苏1 h IVCmax、IVC min、GEDV、ITBV及CI均显著大于休克时(P<0.01),SVV及IVCrvi均显著小于休克时(P<0.01);液体复苏6 h IVCmax、IWCmin、GEDV、ITBV及CI均显著大于休克时(P<0.01)及液体复苏1h(P<0.01),SVV及IVCrvi均显著小于休克时(P<0.01)及液体复苏1 h(P<0.01).IVCmax与SVV有相关性(P =0.024),与GEDV、ITBV及CI无相关性;IVCmin与SVV、GEDV、ITBV及CI均有相关性(分别P=0.009、P=0.003、P=0.001和P=0.015);IVCrvi与SVV、GEDV、ITBV及CI均有相关性(分别P=0.007、P<0.01、P<0.01和P<0.01).结论 下腔静脉管径及呼吸变异指数与PiCC0血流动力学指标具有相关性,可以为临床医师快速评估血容量提供依据.%Objective To explore the correlation between radius and respiratory variation of inferior vena cava(IVC)and hemodynamic monitoring values of pulse-indicated continuous cardiac output(PiCCO)in septic shock pigs.Methods A total of 8 pigs were used to establish animal model of septic shock by intravenous infusing LPS(100 μg/kg),and fluid resuscitation was followed with normal saline.Ultrasound was used to measure the maximum radius

  8. Débito cardíaco diminuído: revisão sistemática das características definidoras Débito cardíaco disminuído: revisión sistemática de las características definidoras Decreased cardiac output: a systematic review of the defining characteristics

    Directory of Open Access Journals (Sweden)

    Vanessa de Souza

    2011-01-01

    explorada. Se constató la importancia del examen físico, la utilización de técnicas menos invasivas y la necesidad de revisar las características definidoras propuestas a fin de proporcionar claridad y objetividad en la identificación de ese diagnóstico de enfermeríaOBJECTIVES: To characterize the scientific articles related to the NANDA-I nursing diagnosis, decreased cardiac output. Verify those articles that describe the behavior of the defining characteristics of this diagnosis, identifying those that occur with the highest frequency. METHODS: A systematic review of literature published between the years 1985 - 2008 was conducted, using the following databases: Lilacs, SciELO, EMBASE, Medline, Pubmed and Cochrane. RESULTS: The sample included 13 articles which identified 50 defining characteristics. Ten characteristics were noted to occur with high frequency: altered heart rate/rhythm, dyspnea, labile blood pressure, rales, oliguria / anuria, edema, cold skin, fatigue / weakness, decreased peripheral pulses and decreased peripheral perfusion. CONCLUSION: This subject has not been explored in depth in the literature. The importance of physical examination, the use of less invasive techniques, and the need to review the proposed defining characteristics to provide clarity and objectivity in the identification of this nursing diagnosis was identified

  9. 脉波指示剂连续心排血量监测技术在早期目标导向治疗中的临床作用分析%Pulse Indicator Continuous Cardiac Output for Hemodynamics Monitoring in Patients with Septic Shock

    Institute of Scientific and Technical Information of China (English)

    陈刚; 王标; 郭小芙

    2014-01-01

    Objective To investigate the application of pulse index continuous cardiac output (PiCCO) in patients with septic shock.MethodsSixty patients with septic shock were randomly divided into two groups: routine monitoring group and PiCCO monitoring group, with 30 patients in each group. The rate of reaching standard of early goal directed therapy (EGDT) was observed after treatment for 6, 24 and 48 hours. In addition, blood lactic acid, central venous oxygen saturation (ScvO2), central venous pressure (CVP), mean arterial pressure (MAP) and urine volume were determined after treatment for 6, 24 and 48 hours, and positive fluid balance amount and dosages of dopamine and dobutamine were measured after treatment for 6, 24 and 48 hours. Mortality was observed in the patients of both groups.Results After treatment for 6, 24 and 48 hours, in PiCCO monitoring group, ScvO2 signifi cantly increased, blood lactic acid level, positivefl uid balance amount, dosages of dopamine and dobutamine signifi cantly decreased compared with routine monitoring group (P<0.05). The rate of reaching standard of EGDT in PiCCO monitoring group was signifi cantly higher than that in routine monitoring group after treatment for 6, 24 hours. There also was difference in mortality between the two groups (P<0.05).Conclusion PiCCO monitor has an important clinical guide signifi cance for the resuscitation of septic shock, which can help to reach the fast and effective treatment target, improve septic shock, avoid the damage of blindfl uid infusion, provide fast and right treatment evidence. So it is worth being spread in clinic treatment.%目的:探讨脉波指示剂连续心排血量监测(PiCCO)技术在脓毒性休克患者早期目标导向治疗(EGDT)中的临床指导价值。方法将60例脓毒性休克患者按随机数字表法分为常规监测组和PiCCO监测组各30例,PiCCO监测组在PiCCO技术指导下行EGDT,常规监测组患者放置中心静脉导管和桡动脉导

  10. Mechanisms of cardiac pain.

    Science.gov (United States)

    Foreman, Robert D; Garrett, Kennon M; Blair, Robert W

    2015-04-01

    Angina pectoris is cardiac pain that typically is manifested as referred pain to the chest and upper left arm. Atypical pain to describe localization of the perception, generally experienced more by women, is referred to the back, neck, and/or jaw. This article summarizes the neurophysiological and pharmacological mechanisms for referred cardiac pain. Spinal cardiac afferent fibers mediate typical anginal pain via pathways from the spinal cord to the thalamus and ultimately cerebral cortex. Spinal neurotransmission involves substance P, glutamate, and transient receptor potential vanilloid-1 (TRPV1) receptors; release of neurokinins such as nuclear factor kappa b (NF-kb) in the spinal cord can modulate neurotransmission. Vagal cardiac afferent fibers likely mediate atypical anginal pain and contribute to cardiac ischemia without accompanying pain via relays through the nucleus of the solitary tract and the C1-C2 spinal segments. The psychological state of an individual can modulate cardiac nociception via pathways involving the amygdala. Descending pathways originating from nucleus raphe magnus and the pons also can modulate cardiac nociception. Sensory input from other visceral organs can mimic cardiac pain due to convergence of this input with cardiac input onto spinothalamic tract neurons. Reduction of converging nociceptive input from the gallbladder and gastrointestinal tract can diminish cardiac pain. Much work remains to be performed to discern the interactions among complex neural pathways that ultimately produce or do not produce the sensations associated with cardiac pain.

  11. Full Static Output Feedback Equivalence

    Directory of Open Access Journals (Sweden)

    Aristotle G. Yannakoudakis

    2013-01-01

    Full Text Available We present a constructive solution to the problem of full output feedback equivalence, of linear, minimal, time-invariant systems. The equivalence relation on the set of systems is transformed to another on the set of invertible block Bezout/Hankel matrices using the isotropy subgroups of the full state feedback group and the full output injection group. The transformation achieving equivalence is calculated solving linear systems of equations. We give a polynomial version of the results proving that two systems are full output feedback equivalent, if and only if they have the same family of generalized Bezoutians. We present a new set of output feedback invariant polynomials that generalize the breakaway polynomial of scalar systems.

  12. Stimulating endogenous cardiac regeneration

    Directory of Open Access Journals (Sweden)

    Amanda eFinan

    2015-09-01

    Full Text Available The healthy adult heart has a low turnover of cardiac myocytes. The renewal capacity, however, is augmented after cardiac injury. Participants in cardiac regeneration include cardiac myocytes themselves, cardiac progenitor cells, and peripheral stem cells, particularly from the bone marrow compartment. Cardiac progenitor cells and bone marrow stem cells are augmented after cardiac injury, migrate to the myocardium, and support regeneration. Depletion studies of these populations have demonstrated their necessary role in cardiac repair. However, the potential of these cells to completely regenerate the heart is limited. Efforts are now being focused on ways to augment these natural pathways to improve cardiac healing, primarily after ischemic injury but in other cardiac pathologies as well. Cell and gene therapy or pharmacological interventions are proposed mechanisms. Cell therapy has demonstrated modest results and has passed into clinical trials. However, the beneficial effects of cell therapy have primarily been their ability to produce paracrine effects on the cardiac tissue and recruit endogenous stem cell populations as opposed to direct cardiac regeneration. Gene therapy efforts have focused on prolonging or reactivating natural signaling pathways. Positive results have been demonstrated to activate the endogenous stem cell populations and are currently being tested in clinical trials. A potential new avenue may be to refine pharmacological treatments that are currently in place in the clinic. Evidence is mounting that drugs such as statins or beta blockers may alter endogenous stem cell activity. Understanding the effects of these drugs on stem cell repair while keeping in mind their primary function may strike a balance in myocardial healing. To maximize endogenous cardiac regeneration,a combination of these approaches couldameliorate the overall repair process to incorporate the participation ofmultiple cell players.

  13. Functional and Hemodynamic Cardiac Determinants of Exercise Capacity in Patients With Systolic Heart Failure

    NARCIS (Netherlands)

    Hummel, Yoran M.; Bugatti, Silvia; Damman, Kevin; Willemsen, Suzan; Hartog, Jasper W. L.; Metra, Marco; Sipkens, Johannes S.; van Veldhuisen, Dirk J.; Voors, Adriaan A.

    2012-01-01

    Decreased exercise capacity is the main symptom in patients with heart failure (HF). We assessed the association among noninvasively determined maximal cardiac output at exercise, systolic and diastolic cardiac functions at rest, and peak oxygen uptake (pVO(2)) exercise capacity in patients with con

  14. Marketing cardiac CT programs.

    Science.gov (United States)

    Scott, Jason

    2010-01-01

    There are two components of cardiac CT discussed in this article: coronary artery calcium scoring (CACS) and coronary computed tomography angiography (CCTA).The distinctive advantages of each CT examination are outlined. In order to ensure a successful cardiac CT program, it is imperative that imaging facilities market their cardiac CT practices effectively in order to gain a competitive advantage in this valuable market share. If patients receive quality care by competent individuals, they are more likely to recommend the facility's cardiac CT program. Satisfied patients will also be more willing to come back for any further testing.

  15. Comparação dos efeitos da dobutamina e da milrinona sobre a hemodinâmica e o transporte de oxigênio em pacientes submetidos à cirurgia cardíaca com baixo débito cardíaco após indução anestésica Comparación de los efectos de la dobutamina y de la milrinona sobre la hemodinámica y el transporte de oxígeno en pacientes sometidos a cirugía cardiaca con bajo débito cardiaco después de inducción anestésica Comparison of the effects of dobutamine and milrinone on hemodynamic parameters and oxygen supply in patients undergoing cardiac surgery with low cardiac output after anesthetic induction

    Directory of Open Access Journals (Sweden)

    Maria José Carvalho Carmona

    2010-06-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: Diversas classes de fármacos inotrópicos, com efeitos hemodinâmicos diferentes, são utilizadas no tratamento do baixo débito cardíaco em pacientes com disfunção sistólica submetidos a procedimento cirúrgico cardíaco. O objetivo deste estudo foi comparar o efeito da dobutamina e da milrinona sobre a hemodinâmica e o transporte de oxigênio nessa população de pacientes. MÉTODO: Após aprovação do Comitê de Ética institucional e obtenção do consentimento escrito pós-informado, 20 pacientes submetidos à cirurgia cardíaca e com índice cardíaco JUSTIFICATIVA Y OBJETIVOS: Diversas clases de fármacos inotrópicos con efectos hemodinámicos diferentes, se usan en el tratamiento del bajo débito cardíaco en pacientes con disfunción sistólica sometidos al procedimiento quirúrgico cardíaco. El objetivo de este estudio, fue comparar el efecto de la dobutamina y de la milrinona sobre la hemodinámica y el transporte de oxígeno en esa población de pacientes. MÉTODO: Después de la aprobación del Comité de Ética institucional y de la obtención del consentimiento informado, 20 pacientes sometidos a la cirugía cardíaca y con índice cardíaco BACKGROUND AND OBJECTIVES: Several classes of inotropic drugs with different hemodynamic effects are used in the treatment of low cardiac output in patients with diastolic dysfunction undergoing cardiac surgery. The objective of the present study was to compare the effects of dobutamine and milrinone on hemodynamic parameters and oxygen supply in this population of patients. METHODS: After approval by the Ethics Committee of the institution and signing of the informed consent, 20 patients undergoing cardiac surgery with cardiac index < 2 L.min-1.m2 after anesthetic induction and place ment of a pulmonary artery catheter were randomly divided to receive dobutamine 5 µg.kg-1. min-1 (n = 10, or milrinone 0.5 µg.kg-1.min-1 (n = 10. Hemodynamic parameters were

  16. Remote input/output station

    CERN Multimedia

    1972-01-01

    A general view of the remote input/output station installed in building 112 (ISR) and used for submitting jobs to the CDC 6500 and 6600. The card reader on the left and the line printer on the right are operated by programmers on a self-service basis.

  17. World Input-Output Network.

    Science.gov (United States)

    Cerina, Federica; Zhu, Zhen; Chessa, Alessandro; Riccaboni, Massimo

    2015-01-01

    Production systems, traditionally analyzed as almost independent national systems, are increasingly connected on a global scale. Only recently becoming available, the World Input-Output Database (WIOD) is one of the first efforts to construct the global multi-regional input-output (GMRIO) tables. By viewing the world input-output system as an interdependent network where the nodes are the individual industries in different economies and the edges are the monetary goods flows between industries, we analyze respectively the global, regional, and local network properties of the so-called world input-output network (WION) and document its evolution over time. At global level, we find that the industries are highly but asymmetrically connected, which implies that micro shocks can lead to macro fluctuations. At regional level, we find that the world production is still operated nationally or at most regionally as the communities detected are either individual economies or geographically well defined regions. Finally, at local level, for each industry we compare the network-based measures with the traditional methods of backward linkages. We find that the network-based measures such as PageRank centrality and community coreness measure can give valuable insights into identifying the key industries.

  18. Input/output interface module

    Science.gov (United States)

    Ozyazici, E. M.

    1980-01-01

    Module detects level changes in any of its 16 inputs, transfers changes to its outputs, and generates interrupts when changes are detected. Up to four changes-in-state per line are stored for later retrieval by controlling computer. Using standard TTL logic, module fits 19-inch rack-mounted console.

  19. World Input-Output Network.

    Directory of Open Access Journals (Sweden)

    Federica Cerina

    Full Text Available Production systems, traditionally analyzed as almost independent national systems, are increasingly connected on a global scale. Only recently becoming available, the World Input-Output Database (WIOD is one of the first efforts to construct the global multi-regional input-output (GMRIO tables. By viewing the world input-output system as an interdependent network where the nodes are the individual industries in different economies and the edges are the monetary goods flows between industries, we analyze respectively the global, regional, and local network properties of the so-called world input-output network (WION and document its evolution over time. At global level, we find that the industries are highly but asymmetrically connected, which implies that micro shocks can lead to macro fluctuations. At regional level, we find that the world production is still operated nationally or at most regionally as the communities detected are either individual economies or geographically well defined regions. Finally, at local level, for each industry we compare the network-based measures with the traditional methods of backward linkages. We find that the network-based measures such as PageRank centrality and community coreness measure can give valuable insights into identifying the key industries.

  20. Cardiac Procedures and Surgeries

    Science.gov (United States)

    ... Peripheral Artery Disease Venous Thromboembolism Aortic Aneurysm More Cardiac Procedures and Surgeries Updated:Sep 16,2016 If you've had ... degree of coronary artery disease (CAD) you have. Cardiac Procedures and Surgeries Angioplasty Also known as Percutaneous Coronary Interventions [PCI], ...

  1. [Advances in cardiac pacing].

    Science.gov (United States)

    de Carranza, María-José Sancho-Tello; Fidalgo-Andrés, María Luisa; Ferrer, José Martínez; Mateas, Francisco Ruiz

    2012-01-01

    This article contains a review of the current status of remote monitoring and follow-up involving cardiac pacing devices and of the latest developments in cardiac resynchronization therapy. In addition, the most important articles published in the last year are discussed.

  2. Biomaterials for cardiac regeneration

    CERN Document Server

    Ruel, Marc

    2015-01-01

    This book offers readers a comprehensive biomaterials-based approach to achieving clinically successful, functionally integrated vasculogenesis and myogenesis in the heart. Coverage is multidisciplinary, including the role of extracellular matrices in cardiac development, whole-heart tissue engineering, imaging the mechanisms and effects of biomaterial-based cardiac regeneration, and autologous bioengineered heart valves. Bringing current knowledge together into a single volume, this book provides a compendium to students and new researchers in the field and constitutes a platform to allow for future developments and collaborative approaches in biomaterials-based regenerative medicine, even beyond cardiac applications. This book also: Provides a valuable overview of the engineering of biomaterials for cardiac regeneration, including coverage of combined biomaterials and stem cells, as well as extracellular matrices Presents readers with multidisciplinary coverage of biomaterials for cardiac repair, including ...

  3. Mathematical cardiac electrophysiology

    CERN Document Server

    Colli Franzone, Piero; Scacchi, Simone

    2014-01-01

    This book covers the main mathematical and numerical models in computational electrocardiology, ranging from microscopic membrane models of cardiac ionic channels to macroscopic bidomain, monodomain, eikonal models and cardiac source representations. These advanced multiscale and nonlinear models describe the cardiac bioelectrical activity from the cell level to the body surface and are employed in both the direct and inverse problems of electrocardiology. The book also covers advanced numerical techniques needed to efficiently carry out large-scale cardiac simulations, including time and space discretizations, decoupling and operator splitting techniques, parallel finite element solvers. These techniques are employed in 3D cardiac simulations illustrating the excitation mechanisms, the anisotropic effects on excitation and repolarization wavefronts, the morphology of electrograms in normal and pathological tissue and some reentry phenomena. The overall aim of the book is to present rigorously the mathematica...

  4. State-shared model for multiple-input multiple-output systems

    Institute of Scientific and Technical Information of China (English)

    Zhenhua TIAN; Karlene A. HOO

    2005-01-01

    This work proposes a method to construct a state-shared model for multiple-input multiple-output (MIMO)systems. A state-shared model is defined as a linear time invariant state-space structure that is driven by measurement signals-the plant outputs and the manipulated variables, but shared by different multiple input/output models. The genesis of the state-shared model is based on a particular reduced non-minimal realization. Any such realization necessarily fulfills the requirement that the output of the state-shared model is an asymptotically correct estimate of the output of the plant, if the process model is selected appropriately. The approach is demonstrated on a nonlinear MIMO system- a physiological model of calcium fluxes that controls muscle contraction and relaxation in human cardiac myocytes.

  5. UFO - The Universal FEYNRULES Output

    Science.gov (United States)

    Degrande, Céline; Duhr, Claude; Fuks, Benjamin; Grellscheid, David; Mattelaer, Olivier; Reiter, Thomas

    2012-06-01

    We present a new model format for automatized matrix-element generators, the so-called Universal FEYNRULES Output (UFO). The format is universal in the sense that it features compatibility with more than one single generator and is designed to be flexible, modular and agnostic of any assumption such as the number of particles or the color and Lorentz structures appearing in the interaction vertices. Unlike other model formats where text files need to be parsed, the information on the model is encoded into a PYTHON module that can easily be linked to other computer codes. We then describe an interface for the MATHEMATICA package FEYNRULES that allows for an automatic output of models in the UFO format.

  6. Cardiac tumors: echo assessment.

    Science.gov (United States)

    Mankad, Rekha; Herrmann, Joerg

    2016-12-01

    Cardiac tumors are exceedingly rare (0.001-0.03% in most autopsy series). They can be present anywhere within the heart and can be attached to any surface or be embedded in the myocardium or pericardial space. Signs and symptoms are nonspecific and highly variable related to the localization, size and composition of the cardiac mass. Echocardiography, typically performed for another indication, may be the first imaging modality alerting the clinician to the presence of a cardiac mass. Although echocardiography cannot give the histopathology, certain imaging features and adjunctive tools such as contrast imaging may aid in the differential diagnosis as do the adjunctive clinical data and the following principles: (1) thrombus or vegetations are the most likely etiology, (2) cardiac tumors are mostly secondary and (3) primary cardiac tumors are mostly benign. Although the finding of a cardiac mass on echocardiography may generate confusion, a stepwise approach may serve well practically. Herein, we will review such an approach and the role of echocardiography in the assessment of cardiac masses.

  7. Airway Management of the Cardiac Surgical Patients: Current Perspective

    Science.gov (United States)

    Choudhury, Arindam; Gupta, Nishkarsh; Magoon, Rohan; Kapoor, Poonam Malhotra

    2017-01-01

    The difficult airway (DA) is a common problem encountered in patients undergoing cardiac surgery. However, the challenge is not only just establishment of airway but also maintaining a definitive airway for the safe conduct of cardiopulmonary bypass from initiation to weaning after surgical correction or palliation, de-airing of cardiac chambers. This review describes the management of the DA in a cardiac theater environment. The primary aims are recognition of DA both anatomical and physiological, necessary preparations for (and management of) difficult intubation and extubation. All patients undergoing cardiac surgery should initially be considered as having potentially DA as many of them have poor physiologic reserve. Making the cardiac surgical theater environment conducive to DA management is as essential as it is to deal with low cardiac output syndrome or acute heart failure. Tube obstruction and/or displacement should be suspected in case of a new onset ventilation problem, especially in the recovery unit. Cardiac anesthesiologists are often challenged with DA while inducing general endotracheal anesthesia. They ought to be familiar with the DA algorithms and possess skill for using the latest airway adjuncts. PMID:28074820

  8. Molecular Basis of Cardiac Myxomas

    Directory of Open Access Journals (Sweden)

    Pooja Singhal

    2014-01-01

    Full Text Available Cardiac tumors are rare, and of these, primary cardiac tumors are even rarer. Metastatic cardiac tumors are about 100 times more common than the primary tumors. About 90% of primary cardiac tumors are benign, and of these the most common are cardiac myxomas. Approximately 12% of primary cardiac tumors are completely asymptomatic while others present with one or more signs and symptoms of the classical triad of hemodynamic changes due to intracardiac obstruction, embolism and nonspecific constitutional symptoms. Echocardiography is highly sensitive and specific in detecting cardiac tumors. Other helpful investigations are chest X-rays, magnetic resonance imaging and computerized tomography scan. Surgical excision is the treatment of choice for primary cardiac tumors and is usually associated with a good prognosis. This review article will focus on the general features of benign cardiac tumors with an emphasis on cardiac myxomas and their molecular basis.

  9. Successful use of levosimendan as a primary inotrope in pediatric cardiac surgery: An observational study in 110 patients

    Directory of Open Access Journals (Sweden)

    Reena Khantwal Joshi

    2016-01-01

    Conclusions: Levosimendan-based inotropic regime offers optimized cardiac output with a well-controlled heart rate and a low incidence of arrhythmias in patients undergoing all categories of congenital heart surgeries.

  10. Cardiac Tumors; Tumeurs cardiaques

    Energy Technology Data Exchange (ETDEWEB)

    Laissy, J.P.; Fernandez, P. [Centre Hospitalier Universitaire Bichat Claude Bernard, Service d' Imagerie, 76 - Rouen (France); Mousseaux, E. [Hopital Europeen Georges Pompidou (HEGP), Service de Radiologie Cardio Vasculaire et Interventionnelle, 75 - Paris (France); Dacher, J.N. [Centre Hospitalier Universitaire Charles Nicolle, 75 - Rouen (France); Crochet, D. [Centre Hospitalier Universitaire, Hopital Laennec, Centre Hemodynamique, Radiologie Thoracique et Vasculaire, 44 - Nantes (France)

    2004-04-01

    Metastases are the most frequent tumors of the heart even though they seldom are recognized. Most primary cardiac tumors are benign. The main role of imaging is to differentiate a cardiac tumor from thrombus and rare pseudo-tumors: tuberculoma, hydatid cyst. Echocardiography is the fist line imaging technique to detect cardiac tumors, but CT and MRl arc useful for further characterization and differential diagnosis. Myxoma of the left atrium is the most frequent benign cardiac tumor. It usually is pedunculated and sometimes calcified. Sarcoma is the most frequent primary malignant tumor and usually presents as a sessile infiltrative tumor. Lymphoma and metastases are usually recognized by the presence of known tumor elsewhere of by characteristic direct contiguous involvement. Diagnosing primary and secondary pericardial tumors often is difficult. Imaging is valuable for diagnosis, characterization, pre-surgical evaluation and follow-up. (author)

  11. Socially differentiated cardiac rehabilitation

    DEFF Research Database (Denmark)

    Meillier, Lucette Kirsten; Nielsen, Kirsten Melgaard; Larsen, Finn Breinholt;

    2012-01-01

    to a standard rehabilitation programme (SRP). If patients were identified as socially vulnerable, they were offered an extended version of the rehabilitation programme (ERP). Excluded patients were offered home visits by a cardiac nurse. Concordance principles were used in the individualised programme elements......%. Patients were equally distributed to the SRP and the ERP. No inequality was found in attendance and adherence among referred patients. Conclusions: It seems possible to overcome unequal referral, attendance, and adherence in cardiac rehabilitation by organisation of systematic screening and social......Aim: The comprehensive cardiac rehabilitation (CR) programme after myocardial infarction (MI) improves quality of life and results in reduced cardiac mortality and recurrence of MI. Hospitals worldwide face problems with low participation rates in rehabilitation programmes. Inequality...

  12. Cardiac arrest - cardiopulmonary resuscitation

    Institute of Scientific and Technical Information of China (English)

    Basri Lenjani; Besnik Elshani; Nehat Baftiu; Kelmend Pallaska; Kadir Hyseni; Njazi Gashi; Nexhbedin Karemani; Ilaz Bunjaku; Taxhidin Zaimi; Arianit Jakupi

    2014-01-01

    Objective:To investigate application of cardiopulmonary resuscitation(CPR) measures within the golden minutes inEurope.Methods:The material was taken from theUniversityClinical Center ofKosovo -EmergencyCentre inPristina, during the two(2) year period(2010-2011).The collected date belong to the patients with cardiac arrest have been recorded in the patients' log book protocol at the emergency clinic.Results:During the2010 to2011 in the emergency center of theCUCK inPristina have been treated a total of269 patients with cardiac arrest, of whom159 or59.1% have been treated in2010, and110 patients or40.9% in2011.Of the269 patients treated in the emergency centre,93 or34.6% have exited lethally in the emergency centre, and176 or 65.4% have been transferred to other clinics.In the total number of patients with cardiac arrest, males have dominated with186 cases, or69.1%.The average age of patients included in the survey was56.7 year oldSD±16.0 years.Of the269 patients with cardiac arrest, defibrillation has been applied for93 or34.6% of patients.In the outpatient settings defibrillation has been applied for3 or3.2% of patients.Patients were defibrillated with application of one to four shocks. Of27 cases with who have survived cardiac arrest, none of them have suffered cardiac arrest at home,3 or11.1% of them have suffered cardiac arrest on the street, and24 or88.9% of them have suffered cardiac arrest in the hospital.5 out of27 patients survived have ended with neurological impairment.Cardiac arrest cases were present during all days of the week, but frequently most reported cases have been onMonday with32.0% of cases, and onFriday with24.5% of cases. Conclusions:All survivors from cardiac arrest have received appropriate medical assistance within10 min from attack, which implies that if cardiac arrest occurs near an institution health care(with an opportunity to provide the emergent health care) the rate of survival is higher.

  13. Cardiac imaging in adults

    Energy Technology Data Exchange (ETDEWEB)

    Jaffe, C.C.

    1987-01-01

    This book approaches adult cardiac disease from the correlative imaging perspective. It includes chest X-rays and angiographs, 2-dimensional echocardiograms with explanatory diagrams for clarity, plus details on digital radiology, nuclear medicine techniques, CT and MRI. It also covers the normal heart, valvular heart disease, myocardial disease, pericardial disease, bacterial endocarditis, aortic aneurysm, cardiac tumors, and congenital heart disease of the adult. It points out those aspects where one imaging technique has significant superiority.

  14. Port Access Cardiac Surgery.

    Science.gov (United States)

    Viganó, Mario; Minzioni, Gaetano; Spreafico, Patrizio; Rinaldi, Mauro; Pasquino, Stefano; Ceriana, Piero; Locatelli, Alessandro

    2000-10-01

    The port-access technique for cardiac surgery was recently developed at Stanford University in California as a less invasive method to perform some cardiac operations. The port-access system has been described in detail elsewhere. It is based on femoral arterial and venous access for cardiopulmonary bypass (CPB) and on the adoption of a specially designed triple-lumen catheter described originally by Peters, and subsequently modified and developed in the definitive configuration called the endoaortic clamp.

  15. Awareness in cardiac anesthesia.

    LENUS (Irish Health Repository)

    Serfontein, Leon

    2010-02-01

    Cardiac surgery represents a sub-group of patients at significantly increased risk of intraoperative awareness. Relatively few recent publications have targeted the topic of awareness in this group. The aim of this review is to identify areas of awareness research that may equally be extrapolated to cardiac anesthesia in the attempt to increase understanding of the nature and significance of this scenario and how to reduce it.

  16. Post cardiac injury syndrome

    DEFF Research Database (Denmark)

    Nielsen, S L; Nielsen, F E

    1991-01-01

    The post-pericardiotomy syndrome is a symptom complex which is similar in many respects to the post-myocardial infarction syndrome and these are summarized under the diagnosis of the Post Cardiac Injury Syndrome (PCIS). This condition, which is observed most frequently after open heart surgery, i...... on the coronary vessels, with cardiac tamponade and chronic pericardial exudate. In the lighter cases, PCIS may be treated with NSAID and, in the more severe cases, with systemic glucocorticoid which has a prompt effect....

  17. Autonomic cardiac innervation

    OpenAIRE

    Hasan, Wohaib

    2013-01-01

    Autonomic cardiac neurons have a common origin in the neural crest but undergo distinct developmental differentiation as they mature toward their adult phenotype. Progenitor cells respond to repulsive cues during migration, followed by differentiation cues from paracrine sources that promote neurochemistry and differentiation. When autonomic axons start to innervate cardiac tissue, neurotrophic factors from vascular tissue are essential for maintenance of neurons before they reach their targe...

  18. Infected cardiac hydatid cyst

    OpenAIRE

    Ceviz, M; Becit, N; Kocak, H.

    2001-01-01

    A 24 year old woman presented with chest pain and palpitation. The presence of a semisolid mass—an echinococcal cyst or tumour—in the left ventricular apex was diagnosed by echocardiography, computed tomography, and magnetic resonance imaging. The infected cyst was seen at surgery. The cyst was removed successfully by using cardiopulmonary bypass with cross clamp.


Keywords: cardiac hydatid cyst; infected cardiac hydatid cyst

  19. Judicial Influence on Policy Outputs?

    DEFF Research Database (Denmark)

    Martinsen, Dorte Sindbjerg

    2015-01-01

    to override unwanted jurisprudence. In this debate, the Court of Justice of the European Union (CJEU) has become famous for its central and occasionally controversial role in European integration. This article examines to what extent and under which conditions judicial decisions influence European Union (EU......) social policy outputs. A taxonomy of judicial influence is constructed, and expectations of institutional and political conditions on judicial influence are presented. The analysis draws on an extensive novel data set and examines judicial influence on EU social policies over time, that is, between 1958...

  20. Cardiac applications of optogenetics.

    Science.gov (United States)

    Ambrosi, Christina M; Klimas, Aleksandra; Yu, Jinzhu; Entcheva, Emilia

    2014-08-01

    In complex multicellular systems, such as the brain or the heart, the ability to selectively perturb and observe the response of individual components at the cellular level and with millisecond resolution in time, is essential for mechanistic understanding of function. Optogenetics uses genetic encoding of light sensitivity (by the expression of microbial opsins) to provide such capabilities for manipulation, recording, and control by light with cell specificity and high spatiotemporal resolution. As an optical approach, it is inherently scalable for remote and parallel interrogation of biological function at the tissue level; with implantable miniaturized devices, the technique is uniquely suitable for in vivo tracking of function, as illustrated by numerous applications in the brain. Its expansion into the cardiac area has been slow. Here, using examples from published research and original data, we focus on optogenetics applications to cardiac electrophysiology, specifically dealing with the ability to manipulate membrane voltage by light with implications for cardiac pacing, cardioversion, cell communication, and arrhythmia research, in general. We discuss gene and cell delivery methods of inscribing light sensitivity in cardiac tissue, functionality of the light-sensitive ion channels within different types of cardiac cells, utility in probing electrical coupling between different cell types, approaches and design solutions to all-optical electrophysiology by the combination of optogenetic sensors and actuators, and specific challenges in moving towards in vivo cardiac optogenetics.

  1. Integration of TMVA Output into Jupyter notebooks

    CERN Document Server

    Saliji, Albulena

    2016-01-01

    The purpose of this report is to describe the work that I have been doing during these past eight weeks as a Summer Student at CERN. The task which was assigned to me had to do with the integration of TMVA Output into Jupyter notebooks. In order to integrate the TMVA Output into the Jupyter notebook, first, improvement of the TMVA Output in the terminal was required. Once the output was improved, it needed to be transformed into HTML output and at the end it would be possible to integrate that output into the Jupyter notebook.

  2. Relationship between peak cardiac pumping capability and indices of cardio-respiratory fitness in healthy individuals.

    Science.gov (United States)

    Jakovljevic, Djordje G; Popadic-Gacesa, Jelena Z; Barak, Otto F; Nunan, David; Donovan, Gay; Trenell, Michael I; Grujic, Nikola G; Brodie, David A

    2012-09-01

    Cardiac power output (CPO) is a unique and direct measure of overall cardiac function (i.e. cardiac pumping capability) that integrates both flow- and pressure-generating capacities of the heart. The present study assessed the relationship between peak exercise CPO and selected indices of cardio-respiratory fitness. Thirty-seven healthy adults (23 men and 14 women) performed an incremental exercise test to volitional fatigue using the Bruce protocol with gas exchange and ventilatory measurements. Following a 40-min recovery, the subjects performed a constant maximum workload exercise test at or above 95% of maximal oxygen consumption. Cardiac output was measured using the exponential CO(2) rebreathing method. The CPO, expressed in W, was calculated as the product of the mean arterial blood pressure and cardiac output. At peak exercise, CPO was well correlated with cardiac output (r = 0·92, P<0·01), stroke volume (r = 0·90, P<0·01) and peak oxygen consumption (r = 0·77, P<0·01). The coefficient of correlation was moderate between CPO and anaerobic threshold (r = 0·47, P<0·01), oxygen pulse (r = 0·57, P<0·01), minute ventilation (r = 0·53, P<0·01) and carbon dioxide production (r = 0·56, P<0·01). Small but significant relationship was found between peak CPO and peak heart rate (r = 0·23, P<0·05). These findings suggest that only peak cardiac output and stroke volume truly reflect CPO. Other indices of cardio-respiratory fitness such as oxygen consumption, anaerobic threshold, oxygen pulse, minute ventilation, carbon dioxide production and heart rate should not be used as surrogates for overall cardiac function and pumping capability of the heart.

  3. [Psychosomatic aspects of cardiac arrhythmias].

    Science.gov (United States)

    Siepmann, Martin; Kirch, Wilhelm

    2010-07-01

    Emotional stress facilitates the occurrence of cardiac arrhythmias including sudden cardiac death. The prevalence of anxiety and depression is increased in cardiac patients as compared to the normal population. The risk of cardiovascular mortality is enhanced in patients suffering from depression. Comorbid anxiety disorders worsen the course of cardiac arrhythmias. Disturbance of neurocardiac regulation with predominance of the sympathetic tone is hypothesized to be causative for this. The emotional reaction to cardiac arrhythmias is differing to a large extent between individuals. Emotional stress may result from coping with treatment of cardiac arrhythmias. Emotional stress and cardiac arrhythmias may influence each other in the sense of a vicious circle. Somatoform cardiac arrhythmias are predominantly of psychogenic origin. Instrumental measures and frequent contacts between physicians and patients may facilitate disease chronification. The present review is dealing with the multifaceted relationships between cardiac arrhythmias and emotional stress. The underlying mechanisms and corresponding treatment modalities are discussed.

  4. Intensive insulin therapy in the intensive cardiac care unit.

    Science.gov (United States)

    Hasin, Tal; Eldor, Roy; Hammerman, Haim

    2006-01-01

    Treatment in the intensive cardiac care unit (ICCU) enables rigorous control of vital parameters such as heart rate, blood pressure, body temperature, oxygen saturation, serum electrolyte levels, urine output and many others. The importance of controlling the metabolic status of the acute cardiac patient and specifically the level of serum glucose was recently put in focus but is still underscored. This review aims to explain the rationale for providing intensive control of serum glucose levels in the ICCU, especially using intensive insulin therapy and summarizes the available clinical evidence suggesting its effectiveness.

  5. Judicial Influence on Policy Outputs?

    DEFF Research Database (Denmark)

    Martinsen, Dorte Sindbjerg

    2015-01-01

    The ability of courts to generate political change has long been debated in national, comparative, and international politics. In the examination of the interaction between judicial and legislative politics, scholars have disagreed on the degree of judicial power and the ability of politics...... to override unwanted jurisprudence. In this debate, the Court of Justice of the European Union (CJEU) has become famous for its central and occasionally controversial role in European integration. This article examines to what extent and under which conditions judicial decisions influence European Union (EU......) social policy outputs. A taxonomy of judicial influence is constructed, and expectations of institutional and political conditions on judicial influence are presented. The analysis draws on an extensive novel data set and examines judicial influence on EU social policies over time, that is, between 1958...

  6. Output regulation problem for discrete-time linear time-delay systems by output feedback control

    Institute of Scientific and Technical Information of China (English)

    Yamin YAN; Jie HUANG

    2016-01-01

    In this paper, we study the output regulation problem of discrete linear time-delay systems by output feedback control. We have established some results parallel to those for the output regulation problem of continuous linear time-delay systems.

  7. Cardiac radiology: centenary review.

    Science.gov (United States)

    de Roos, Albert; Higgins, Charles B

    2014-11-01

    During the past century, cardiac imaging technologies have revolutionized the diagnosis and treatment of acquired and congenital heart disease. Many important contributions to the field of cardiac imaging were initially reported in Radiology. The field developed from the early stages of cardiac imaging, including the use of coronary x-ray angiography and roentgen kymography, to nowadays the widely used echocardiographic, nuclear medicine, cardiac computed tomographic (CT), and magnetic resonance (MR) applications. It is surprising how many of these techniques were not recognized for their potential during their early inception. Some techniques were described in the literature but required many years to enter the clinical arena and presently continue to expand in terms of clinical application. The application of various CT and MR contrast agents for the diagnosis of myocardial ischemia is a case in point, as the utility of contrast agents continues to expand the noninvasive characterization of myocardium. The history of cardiac imaging has included a continuous process of advances in our understanding of the anatomy and physiology of the cardiovascular system, along with advances in imaging technology that continue to the present day.

  8. Cardiac abnormalities in children with hyperthyroidism.

    Science.gov (United States)

    Lester, L A; Sodt, P C; Rich, B H; Lucky, A W; Hutcheon, N; Arcilla, R A

    1982-01-01

    The cardiac status of 18 hyperthyroid (HT) children (9 black and 9 white) was evaluated by echocardiography. Mitral regurgitation (MR) was diagnosed clinically in 33% (6 of the 9 blacks). None of the 9 white children had MR. Left ventricular end-diastolic diameter (LVEDD) and volume (LVEDV) did not differ from the predicted normal (PN) based on body surface area and heart rate, except in those with MR where increased LVEDD and LVEDV were noted (p less than 0.02). LV mass was +1.75 standard deviations (sigma) of the PN (p less than 0.01), due to increased wall thickness of LVEDV. Left ventricular output (LVO) was +0.35 sigma PN (p = ns); however, when compared to that of normal children, LVO of HT was higher (p less than 0.001) due to the increased heart rate. Enhanced left ventricular contractility was suggested by increased rate of dimensional change during ejection (peak dD/dt-syst), with a mean value of -11.39 cm/sec as compared to the normal of -9.54 cm/sec (p less than 0.01). A linear multivariate regression equation differentiated the cardiac status of HT from that of normal children. Following treatment to euthyroid state, MR disappeared in 2 and became less in 4 patients. LVO, LV mass, and peak dD/dt-syst also became less. Significant cardiac changes occur in children with hyperthyroidism, which may be reversible in part after euthyroidism is restored.

  9. Comprehensive cardiac rehabilitation

    DEFF Research Database (Denmark)

    Kruse, Marie; Hochstrasser, Stefan; Zwisler, Ann-Dorthe O;

    2006-01-01

    OBJECTIVES: The costs of comprehensive cardiac rehabilitation are established and compared to the corresponding costs of usual care. The effect on health-related quality of life is analyzed. METHODS: An unprecedented and very detailed cost assessment was carried out, as no guidelines existed...... for the situation at hand. Due to challenging circumstances, the cost assessment turned out to be ex-post and top-down. RESULTS: Cost per treatment sequence is estimated to be approximately euro 976, whereas the incremental cost (compared with usual care) is approximately euro 682. The cost estimate is uncertain...... and may be as high as euro 1.877. CONCLUSIONS: Comprehensive cardiac rehabilitation is more costly than usual care, and the higher costs are not outweighed by a quality of life gain. Comprehensive cardiac rehabilitation is, therefore, not cost-effective....

  10. Toothache of cardiac origin.

    Science.gov (United States)

    Kreiner, M; Okeson, J P

    1999-01-01

    Pain referred to the orofacial structures can sometimes be a diagnostic challenge for the clinician. In some instances, a patient may complain of tooth pain that is completely unrelated to any dental source. This poses a diagnostic and therapeutic problem for the dentist. Cardiac pain most commonly radiates to the left arm, shoulder, neck, and face. In rare instances, angina pectoris may present as dental pain. When this occurs, an improper diagnosis frequently leads to unnecessary dental treatment or, more significantly, a delay of proper treatment. This delay may result in the patient experiencing an acute myocardial infarction. It is the dentist's responsibility to establish a proper diagnosis so that the treatment will be directed toward the source of pain and not to the site of pain. This article reviews the literature concerning referred pain of cardiac origin and presents a case report of toothache of cardiac origin.

  11. The cardiac anxiety questionnaire: cross-validation among cardiac inpatients

    NARCIS (Netherlands)

    Beek, M.H. van; Oude Voshaar, R.C.; Deelen, F.M. van; Balkom, A.J. van; Pop, G.A.; Speckens, A.E.

    2012-01-01

    OBJECTIVE: General anxiety symptoms are common in patients with cardiac disease and considered to have an adverse effect on cardiac prognosis. The role of specific cardiac anxiety, however, is still unknown. The aim of this study is to examine the factor structure, reliability, and validity of the D

  12. THE CARDIAC ANXIETY QUESTIONNAIRE : CROSS-VALIDATION AMONG CARDIAC INPATIENTS

    NARCIS (Netherlands)

    van Beek, M. H. C. T.; Voshaar, R. C. Oude; van Deelen, F. M.; van Balkom, A. J. L. M.; Pop, G.; Speckens, A. E. M.

    2012-01-01

    Objective: General anxiety symptoms are common in patients with cardiac disease and considered to have an adverse effect on cardiac prognosis. The role of specific cardiac anxiety, however, is still unknown. The aim of this study is to examine the factor structure, reliability, and validity of the D

  13. Perioperative management of cardiac disease.

    Science.gov (United States)

    Aresti, N A; Malik, A A; Ihsan, K M; Aftab, S M E; Khan, W S

    2014-01-01

    Pre-existing cardiac disease contributes significantly to morbidity and mortality amongst patients undergoing non cardiac surgery. Patients with pre-existing cardiac disease or with risk factors for it, have as much as a 3.9% risk of suffering a major perioperative cardiac event (Lee et al 1999, Devereaux 2005). Furthermore, the incidence of perioperative myocardial infarction (MI) is increased 10 to 50 fold in patients with previous coronary events (Jassal 2008).

  14. Reduced pallidal output causes dystonia

    Directory of Open Access Journals (Sweden)

    Atsushi eNambu

    2011-11-01

    Full Text Available Dystonia is a neurological disorder characterized by sustained or repetitive involuntary muscle contractions and abnormal postures. In the present article, we will introduce our recent electrophysiological studies in hyperkinetic transgenic mice generated as a model of DYT1 dystonia and in a human cervical dystonia patient, and discuss the pathophysiology of dystonia on the basis of these electrophysiological findings. Recording of neuronal activity in the awake state of DYT1 dystonia model mice revealed reduced spontaneous activity with bursts and pauses in both internal (GPi and external (GPe segments of the globus pallidus. Electrical stimulation of the primary motor cortex evoked responses composed of excitation and subsequent long-lasting inhibition, the latter of which was never observed in normal mice. In addition, somatotopic arrangements were disorganized in the GPi and GPe of dystonia model mice. In a human cervical dystonia patient, electrical stimulation of the primary motor cortex evoked similar long-lasting inhibition in the GPi and GPe. Thus, reduced GPi output may cause increased thalamic and cortical activity, resulting in the involuntary movements observed in dystonia.

  15. Model output: fact or artefact?

    Science.gov (United States)

    Melsen, Lieke

    2015-04-01

    As a third-year PhD-student, I relatively recently entered the wonderful world of scientific Hydrology. A science that has many pillars that directly impact society, for example with the prediction of hydrological extremes (both floods and drought), climate change, applications in agriculture, nature conservation, drinking water supply, etcetera. Despite its demonstrable societal relevance, hydrology is often seen as a science between two stools. Like Klemeš (1986) stated: "By their academic background, hydrologists are foresters, geographers, electrical engineers, geologists, system analysts, physicists, mathematicians, botanists, and most often civil engineers." Sometimes it seems that the engineering genes are still present in current hydrological sciences, and this results in pragmatic rather than scientific approaches for some of the current problems and challenges we have in hydrology. Here, I refer to the uncertainty in hydrological modelling that is often neglected. For over thirty years, uncertainty in hydrological models has been extensively discussed and studied. But it is not difficult to find peer-reviewed articles in which it is implicitly assumed that model simulations represent the truth rather than a conceptualization of reality. For instance in trend studies, where data is extrapolated 100 years ahead. Of course one can use different forcing datasets to estimate the uncertainty of the input data, but how to prevent that the output is not a model artefact, caused by the model structure? Or how about impact studies, e.g. of a dam impacting river flow. Measurements are often available for the period after dam construction, so models are used to simulate river flow before dam construction. Both are compared in order to qualify the effect of the dam. But on what basis can we tell that the model tells us the truth? Model validation is common nowadays, but validation only (comparing observations with model output) is not sufficient to assume that a

  16. Data analysis in cardiac arrhythmias.

    Science.gov (United States)

    Rodrigo, Miguel; Pedrón-Torecilla, Jorge; Hernández, Ismael; Liberos, Alejandro; Climent, Andreu M; Guillem, María S

    2015-01-01

    Cardiac arrhythmias are an increasingly present in developed countries and represent a major health and economic burden. The occurrence of cardiac arrhythmias is closely linked to the electrical function of the heart. Consequently, the analysis of the electrical signal generated by the heart tissue, either recorded invasively or noninvasively, provides valuable information for the study of cardiac arrhythmias. In this chapter, novel cardiac signal analysis techniques that allow the study and diagnosis of cardiac arrhythmias are described, with emphasis on cardiac mapping which allows for spatiotemporal analysis of cardiac signals.Cardiac mapping can serve as a diagnostic tool by recording cardiac signals either in close contact to the heart tissue or noninvasively from the body surface, and allows the identification of cardiac sites responsible of the development or maintenance of arrhythmias. Cardiac mapping can also be used for research in cardiac arrhythmias in order to understand their mechanisms. For this purpose, both synthetic signals generated by computer simulations and animal experimental models allow for more controlled physiological conditions and complete access to the organ.

  17. Biosynthesis of cardiac natriuretic peptides

    DEFF Research Database (Denmark)

    Goetze, Jens Peter

    2010-01-01

    Cardiac-derived peptide hormones were identified more than 25 years ago. An astonishing amount of clinical studies have established cardiac natriuretic peptides and their molecular precursors as useful markers of heart disease. In contrast to the clinical applications, the biogenesis of cardiac...

  18. Cardiac and vascular changes in cirrhosis: Pathogenic mechanisms

    Institute of Scientific and Technical Information of China (English)

    HongQun Liu; Seyed Ali Gaskari; Samuel S Lee

    2006-01-01

    Cardiovascular abnormalities accompany both portal hypertension and cirrhosis. These consist of hyperdynamic circulation, defined as reduced mean arterial pressure and systemic vascular resistance, and increased cardiac output. Despite the baseline increased cardiac output,ventricular inotropic and chronotropic responses to stimuli are blunted, a condition known as cirrhotic cardiomyopathy. Both conditions may play an initiating or aggravating pathogenic role in many of the complications of liver failure or portal hypertension including ascites,variceal bleeding, hepatorenal syndrome and increased postoperative mortality after major surgery or liver transplantation. This review briefly examines the major mechanisms that may underlie these cardiovascular abnormalities, concentrating on nitric oxide, endogenous cannabinoids, central neural activation and adrenergic receptor changes. Future work should address the complex interrelationships between these systems.

  19. Cardiac safety in vascular access surgery and maintenance.

    Science.gov (United States)

    Malik, Jan; Kudlicka, Jaroslav; Tesar, Vladimir; Linhart, Ales

    2015-01-01

    More than 50% of all end-stage renal disease (ESRD) patients die from cardiovascular complications. Among them, heart failure and pulmonary hypertension play a major role, and published studies document significantly higher mortality rates in patients with these two states. Arteriovenous fistulas (AVF) and arteriovenous grafts (AVG) are the preferred types of vascular access (VA). However, both AVF and AVG increase cardiac output and in turn could contribute to (the decompensation of) heart failure or pulmonary hypertension. No really safe access flow volume exists, and the ESRD patients' reactions to it vary considerably. We review the mechanisms involved in the cardiovascular consequences of increased cardiac output and available literary data. The link between access flow volume and increased mortality due to pulmonary hypertension or heart failure probably exists, but still has not been directly evidenced. Regular echocardiography is advisable especially in patients with symptoms or with high VA flow (>1,500 ml/min).

  20. Cardiac troponins and high-sensitivity cardiac troponin assays.

    Science.gov (United States)

    Conrad, Michael J; Jarolim, Petr

    2014-03-01

    Measurement of circulating cardiac troponins I and T has become integral to the diagnosis of myocardial infarction. This article discusses the structure and function of the troponin complex and the release of cardiac troponin molecules from the injured cardiomyocyte into the circulation. An overview of current cardiac troponin assays and their classification according to sensitivity is presented. The diagnostic criteria, role, and usefulness of cardiac troponin for myocardial infarction are discussed. In addition, several examples are given of the usefulness of high-sensitivity cardiac troponin assays for short-term and long-term prediction of adverse events.

  1. Cardiac potassium channel subtypes

    DEFF Research Database (Denmark)

    Schmitt, Nicole; Grunnet, Morten; Olesen, Søren-Peter

    2014-01-01

    About 10 distinct potassium channels in the heart are involved in shaping the action potential. Some of the K(+) channels are primarily responsible for early repolarization, whereas others drive late repolarization and still others are open throughout the cardiac cycle. Three main K(+) channels...

  2. Cardiac Risk Assessment

    Science.gov (United States)

    ... Risk Assessment Related tests: Lipid Profile , VLDL Cholesterol , hs-CRP , Lp(a) Overview | Common Questions | Related Pages What ... cardiac risk include: High-sensitivity C-reactive protein (hs-CRP) : Studies have shown that measuring CRP with a ...

  3. The cardiac malpositions.

    Science.gov (United States)

    Perloff, Joseph K

    2011-11-01

    Dextrocardia was known in the 17th century and was 1 of the first congenital malformations of the heart to be recognized. Fifty years elapsed before Matthew Baillie published his account of complete transposition in a human of the thoracic and abdominal viscera to the opposite side from what is natural. In 1858, Thomas Peacock stated that "the heart may be congenitally misplaced in various ways, occupying either an unusual position within the thorax, or being situated external to that cavity." In 1915, Maude Abbott described ectopia cordis, and Richard Paltauf's remarkable illustrations distinguished the various types of dextrocardia. In 1928, the first useful classification of the cardiac malpositions was proposed, and in 1966, Elliott et al's radiologic classification set the stage for clinical recognition. The first section of this review deals with the 3 basic cardiac malpositions in the presence of bilateral asymmetry. The second section deals with cardiac malpositions in the presence of bilateral left-sidedness or right-sidedness. Previous publications on cardiac malpositions are replete with an arcane vocabulary that confounds rather than clarifies. Even if the terms themselves are understood, inherent complexity weighs against clarity. This review was designed as a guided tour of an unfamiliar subject.

  4. Hepato-cardiac disorders

    Institute of Scientific and Technical Information of China (English)

    Yasser; Mahrous; Fouad; Reem; Yehia

    2014-01-01

    Understanding the mutual relationship between the liver and the heart is important for both hepatologists and cardiologists. Hepato-cardiac diseases can be classified into heart diseases affecting the liver, liver diseases affecting the heart, and conditions affecting the heart and the liver at the same time. Differential diagnoses of liver injury are extremely important in a cardiologist’s clinical practice calling for collaboration between cardiologists and hepatologists due to the many other diseases that can affect the liver and mimic haemodynamic injury. Acute and chronic heart failure may lead to acute ischemic hepatitis or chronic congestive hepatopathy. Treatment in these cases should be directed to the primary heart disease. In patients with advanced liver disease, cirrhotic cardiomyopathy may develop including hemodynamic changes, diastolic and systolic dysfunctions, reduced cardiac performance and electrophysiological abnormalities. Cardiac evaluation is important for patients with liver diseases especially before and after liver transplantation. Liver transplantation may lead to the improvement of all cardiac changes and the reversal of cirrhotic cardiomyopathy. There are systemic diseases that may affect both the liver and the heart concomitantly including congenital, metabolic and inflammatory diseases as well as alcoholism. This review highlights these hepatocardiac diseases

  5. Transesophageal Doppler reliably tracks changes in cardiac output in comparison with intermittent pulmonary artery thermodilution in cardiac surgery patients

    DEFF Research Database (Denmark)

    Møller-Sørensen, Hasse; Cordtz, Johan Joakim; Østergaard, Morten;

    2016-01-01

    completed the study. Each patient were placed in the following successive positions: (1) supine, (2) head-down tilt, (3) head-up tilt, (4) supine, (5) supine with phenylephrine administration, (6) pace heart rate 80 beats per minute (bpm), (7) pace heart rate 110 bpm. The agreement of compared data...

  6. Relationship between Multi-Output Partially Bent Functions and Multi-Output Bent Functions

    Institute of Scientific and Technical Information of China (English)

    ZHAO Yaqun; JU Guizhi; WANG Jue

    2006-01-01

    In this paper, the definition of multi-output partially Bent functions is presented and some properties are discussed. Then the relationship between multi-output partially Bent functions and multi-output Bent functions is given in Theorem 4, which includes Walsh spectrum expression and function expression. This shows that multi-output partially Bent functions and multi-output Bent functions can define each other in principle. So we obtain the general method to construct multi-output partially Bent functions from multi-output Bent functions.

  7. The left ventricle as a mechanical engine: from Leonardo da Vinci to the echocardiographic assessment of peak power output-to-left ventricular mass.

    Science.gov (United States)

    Dini, Frank L; Guarini, Giacinta; Ballo, Piercarlo; Carluccio, Erberto; Maiello, Maria; Capozza, Paola; Innelli, Pasquale; Rosa, Gian M; Palmiero, Pasquale; Galderisi, Maurizio; Razzolini, Renato; Nodari, Savina

    2013-03-01

    The interpretation of the heart as a mechanical engine dates back to the teachings of Leonardo da Vinci, who was the first to apply the laws of mechanics to the function of the heart. Similar to any mechanical engine, whose performance is proportional to the power generated with respect to weight, the left ventricle can be viewed as a power generator whose performance can be related to left ventricular mass. Stress echocardiography may provide valuable information on the relationship between cardiac performance and recruited left ventricular mass that may be used in distinguishing between adaptive and maladaptive left ventricular remodeling. Peak power output-to-mass, obtained during exercise or pharmacological stress echocardiography, is a measure that reflects the number of watts that are developed by 100 g of left ventricular mass under maximal stimulation. Power output-to-mass may be calculated as left ventricular power output per 100 g of left ventricular mass: 100× left ventricular power output divided by left ventricular mass (W/100 g). A simplified formula to calculate power output-to-mass is as follows: 0.222 × cardiac output (l/min) × mean blood pressure (mmHg)/left ventricular mass (g). When the integrity of myocardial structure is compromised, a mismatch becomes apparent between maximal cardiac power output and left ventricular mass; when this occurs, a reduction of the peak power output-to-mass index is observed.

  8. Impact of intra-aortic balloon counterpulsation with different balloon volumes on cardiac performance in humans.

    Science.gov (United States)

    Cohen, Marc; Fasseas, Panayotis; Singh, Varinder P; McBride, Ruth; Orford, James L; Kussmaul, William G

    2002-10-01

    Intra-aortic balloon (IAB) counterpulsation can augment the cardiac output. However, the effect of different IAB volumes on cardiac performance has not been adequately evaluated in humans. Eighty-two patients (52 males [63%]; mean age, 65 +/- 12 years; mean body surface area [BSA], 1.8 +/- 0.2 m(2)) had IAB counterpulsation for cardiogenic shock, refractory angina, and preoperatively for high-risk cardiac surgery. Cardiac hemodynamics were prospectively studied during IAB with inflation volumes of 32 vs. 40 cc. Hemodynamic data collected included aortic pressure, pulmonary artery pressure, systemic and mixed venous oxygen saturations, and cardiac output (by Fick). Transthoracic echocardiography (TTE) was used to obtain both velocity time integrals (VTIs) and the area of the left ventricular outflow tract (LVOT). Left ventricular stroke volume was then calculated as LVOT area x VTI. Cardiac output (CO) determined by the Fick method and VTI did not differ significantly (P = NS) between the two inflation volumes (y = 0.002 + 0.97x). In a subgroup of 33 patients with BSA

  9. Effects of dopamine infusion on cardiac and renal blood flows in dogs.

    Science.gov (United States)

    Furukawa, Shuji; Nagashima, Yukiko; Hoshi, Katsuichiro; Hirao, Hidehiro; Tanaka, Ryou; Maruo, Kohji; Yamane, Yoshihisa

    2002-01-01

    In veterinary medicine, dopamine is currently being administered clinically by infusion for treatment of kidney disorders at low doses (high doses (> or = 5 microg/kg/min). However, since high doses of dopamine cause peripheral vasoconstriction due to its effect on alpha adrenoceptors, high doses have no longer been recommended. The present study was conducted to explore possible regimens for the use of dopamine infusion in dogs. The regional (renal and cardiac) blood flow for 60 min was measured by using colored microspheres at three doses (3, 10 and 20 microg/kg/min) of dopamine infusion in healthy anesthetized mongrel dogs. The effects on kidney and peripheral hemodynamics at each dose and the resultant cardiac output, mean arterial blood pressure and total peripheral resistance were determined. Renal blood flow increased markedly at 3 microg/kg/min dopamine. Improvement in hemodynamics indicated by marked increase in cardiac blood flow, cardiac output and mean arterial blood pressure and decreased total peripheral resistance was observed at higher doses (10 and 20 microg/kg/min). At 10 microg/kg/min, in addition to the satisfactory increase in cardiac blood flow, there was also a stable satisfactory increase in renal blood flow. However, at 20 microg/kg/min, increased myocardial oxygen consumption (manifested by marked increased in cardiac output), arrythmia and irregular increase in renal blood flow were detected. This study suggests that the clinical use of dopamine infusion in dogs could be safely expanded to moderately higher doses.

  10. Exceptional cardiac anoxia tolerance in tilapia (Oreochromis hybrid).

    Science.gov (United States)

    Lague, Sabine L; Speers-Roesch, Ben; Richards, Jeffrey G; Farrell, Anthony P

    2012-04-15

    Anoxic survival requires the matching of cardiac ATP supply (i.e. maximum glycolytic potential, MGP) and demand (i.e. cardiac power output, PO). We examined the idea that the previously observed in vivo downregulation of cardiac function during exposure to severe hypoxia in tilapia (Oreochromis hybrid) represents a physiological strategy to reduce routine PO to within the heart's MGP. The MGP of the ectothermic vertebrate heart has previously been suggested to be ∼70 nmol ATP s(-1) g(-1), sustaining a PO of ∼0.7 mW g(-1) at 15°C. We developed an in situ perfused heart preparation for tilapia (Oreochromis hybrid) and characterized the routine and maximum cardiac performance under both normoxic (>20 kPa O(2)) and severely hypoxic perfusion conditions (tilapia heart maintained a routine normoxic cardiac output (Q) and PO under all hypoxic conditions, a result that contrasts with the hypoxic cardiac downregulation previously observed in vivo under less severe conditions. Thus, we conclude that the in vivo downregulation of routine cardiac performance in hypoxia is not needed in tilapia to balance cardiac energy supply and demand. Indeed, the MGP of the tilapia heart proved to be quite exceptional. Measurements of myocardial lactate efflux during severe hypoxia were used to calculate the MGP of the tilapia heart. The MGP was estimated to be 172 nmol ATP s(-1) g(-1) at 22°C, and allowed the heart to generate a PO(max) of at least ∼3.1 mW g(-1), which is only 30% lower than the PO(max) observed with normoxia. Even with this MGP, the additional challenge of acidosis during severe hypoxia decreased maximum ATP turnover rate and PO(max) by 30% compared with severe hypoxia alone, suggesting that there are probably direct effects of acidosis on cardiac contractility. We conclude that the high maximum glycolytic ATP turnover rate and levels of PO, which exceed those measured in other ectothermic vertebrate hearts, probably convey a previously unreported anoxia tolerance

  11. Effects of Obesity on Cardiovascular Hemodynamics, Cardiac Morphology, and Ventricular Function.

    Science.gov (United States)

    Alpert, Martin A; Omran, Jad; Bostick, Brian P

    2016-12-01

    Obesity produces a variety of hemodynamic alterations that may cause changes in cardiac morphology which predispose to left and right ventricular dysfunction. Various neurohormonal and metabolic alterations commonly associated with obesity may contribute to these abnormalities of cardiac structure and function. These changes in cardiovascular hemodynamics, cardiac morphology, and ventricular function may, in severely obese patients, predispose to heart failure, even in the absence of other forms of heart disease (obesity cardiomyopathy). In normotensive obese patients, cardiac involvement is commonly characterized by elevated cardiac output, low peripheral vascular resistance, and increased left ventricular (LV) end-diastolic pressure. Sleep-disordered breathing may lead to pulmonary arterial hypertension and, in association with left heart failure, may contribute to elevation of right heart pressures. These alterations, in association with various neurohormonal and metabolic abnormalities, may produce LV hypertrophy; impaired LV diastolic function; and less commonly, LV systolic dysfunction. Many of these alterations are reversible with substantial voluntary weight loss.

  12. Therapeutic application of inhaled nitric oxide in adult cardiac surgical patients.

    Science.gov (United States)

    Makker, Robina; Mehta, Yatin; Trehan, Naresh; Bapna, Rk

    2006-01-01

    Increased pulmonary vascular resistance can be detrimental to the cardiac output in post-operative cardiac surgical patients. Pulmonary vasodilator therapy by systemic pharmacologic agents is non-selective. Inhaled nitric oxide is a selective pulmonary vasodilator and does not cause systemic hypotension. In this prospective study, 14 adult post-operative cardiac surgical patients with pulmonary hypertension underwent inhaled nitric oxide therapy and their hemodynamic changes were evaluated. Inhaled nitric oxide was administered in doses of 5 ppm-25 ppm. The result was a decrease in pulmonary vascular resistance from 456.57 +/- 137.13 to 357.64 +/- 119.80 dynes-sec- Continued. - See Free Full Text.

  13. Probabilistic Output Analysis by Program Manipulation

    OpenAIRE

    Rosendahl, Mads; Kirkeby, Maja H.

    2015-01-01

    The aim of a probabilistic output analysis is to derive a probability distribution of possible output values for a program from a probability distribution of its input. We present a method for performing static output analysis, based on program transformation techniques. It generates a probability function as a possibly uncomputable expression in an intermediate language. This program is then analyzed, transformed, and approximated. The result is a closed form expression that computes an over...

  14. Sinopec H1 Oil Output Climbs Slightly

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    Sinopec Corp., China's largest oil refiner, announced in late-July that its crude oil output rose 4.33 percent to 163 million barrels year-on-year in the first half. Domestic crude oil output was up 1. 16 percent to 152 million barrels during the period, while overseas output jtmlped 82.46 percent to 11,13 million barrels, according to an unaudited repo,t released by tile company.

  15. The Global NR Output Kept Rising

    Institute of Scientific and Technical Information of China (English)

    Bo Wen

    2011-01-01

    In early November, Association of Natural Rubber Producing Countries in- dicated that from 2005 to 2011, the pro- ducing area and output of the global NR both kept rising. As predicted, the pro- ducing area will be 72 million hectares, the output will be 10.02 million tons and the average output will be 1,392 kg/hectare by the end of2011.

  16. Cardiac fusion and complex congenital cardiac defects in thoracopagus twins: diagnostic value of cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of); Park, Jeong-Jun [University of Ulsan College of Medicine, Asan Medical Center, Department of Pediatric Cardiac Surgery, Seoul (Korea, Republic of); Kim, Ellen Ai-Rhan [University of Ulsan College of Medicine, Asan Medical Center, Division of Neonatology, Department of Pediatrics, Seoul (Korea, Republic of); Won, Hye-Sung [University of Ulsan College of Medicine, Asan Medical Center, Department of Obstetrics and Gynecology, Seoul (Korea, Republic of)

    2014-09-15

    Most thoracopagus twins present with cardiac fusion and associated congenital cardiac defects, and assessment of this anatomy is of critical importance in determining patient care and outcome. Cardiac CT with electrocardiographic triggering provides an accurate and quick morphological assessment of both intracardiac and extracardiac structures in newborns, making it the best imaging modality to assess thoracopagus twins during the neonatal period. In this case report, we highlight the diagnostic value of cardiac CT in thoracopagus twins with an interatrial channel and complex congenital cardiac defects. (orig.)

  17. Exercise efficiency of low power output cycling.

    Science.gov (United States)

    Reger, M; Peterman, J E; Kram, R; Byrnes, W C

    2013-12-01

    Exercise efficiency at low power outputs, energetically comparable to daily living activities, can be influenced by homeostatic perturbations (e.g., weight gain/loss). However, an appropriate efficiency calculation for low power outputs used in these studies has not been determined. Fifteen active subjects (seven females, eight males) performed 14, 5-min cycling trials: two types of seated rest (cranks vertical and horizontal), passive (motor-driven) cycling, no-chain cycling, no-load cycling, cycling at low (10, 20, 30, 40 W), and moderate (50, 60, 80, 100, 120 W) power outputs. Mean delta efficiency was 57% for low power outputs compared to 41.3% for moderate power outputs. Means for gross (3.6%) and net (5.7%) efficiencies were low at the lowest power output. At low power outputs, delta and work efficiency values exceeded theoretical values. In conclusion, at low power outputs, none of the common exercise efficiency calculations gave values comparable to theoretical muscle efficiency. However, gross efficiency and the slope and intercept of the metabolic power vs mechanical power output regression provide insights that are still valuable when studying homeostatic perturbations.

  18. Cardiac nuclear medicine

    Energy Technology Data Exchange (ETDEWEB)

    Gerson, M.C.

    1987-01-01

    The book begins with a review of the radionuclide methods available for evaluating cardiac perfusion and function. The authors discuss planar and tomographic thallium myocardial imaging, first-pass and equilibrium radionuclide angiography, and imaging with infarct-avid tracers. Several common but more specialized procedures are then reviewed: nonogemetric measurement of left ventricular volume, phase (Fourier) analysis, stroke volume ratio, right ventricular function, and diastolic function. A separate chapter is devoted to drug interventions and in particular the use of radionuclide ventriculography to monitor doxorubicin toxicity and therapy of congestive heart failure. The subsequent chapters provide a comprehensive guide to test selection, accuracy, and results in acute myocardial infarction, in postmyocardial infarction, in chronic coronary artery disease, before and after medical or surgical revascularization, in valvular heart disease, in cardiomyopathies, and in cardiac trauma.

  19. Sudden Cardiac Death

    Directory of Open Access Journals (Sweden)

    Yipsy María Gutiérrez Báez

    2015-09-01

    Full Text Available Since the second half of the twentieth century, dying suddenly due to heart-related problems has become the main health issue in all countries where infectious diseases are not prevalent. Sudden death from cardiac causes is an important global health problem. Major databases were searched for the leading causes of sudden cardiac death. It has been demonstrated that there is a group of hereditary diseases with structural alterations or without apparent organic cause that explains many cases of sudden death in young people, whether related or not to physical exertion. Certain population groups are at higher risk for this disease. They are relatively easy to identify and can be the target of primary prevention measures.

  20. Cardiac arrhythmias in pregnancy.

    Science.gov (United States)

    Knotts, Robert J; Garan, Hasan

    2014-08-01

    As more women with repaired congenital heart disease survive to their reproductive years and many other women are delaying pregnancy until later in life, a rising concern is the risk of cardiac arrhythmias during pregnancy. Naturally occurring cardiovascular changes during pregnancy increase the likelihood that a recurrence of a previously experienced cardiac arrhythmia or a de novo arrhythmia will occur. Arrhythmias should be thoroughly investigated to determine if there is a reversible etiology, and risks/benefits of treatment options should be fully explored. We discuss the approach to working up and treating various arrhythmias during pregnancy with attention to fetal and maternal risks as well as treatment of fetal arrhythmias. Acute management in stable patients includes close monitoring and intravenous pharmacologic therapy, while DC cardioversion should be used to terminate arrhythmias in hemodynamically unstable patients. Long-term management may require continued oral antiarrhythmic therapy, with particular attention to fetal safety, to prevent complications associated with arrhythmias.

  1. Cardiac surgery 2015 reviewed.

    Science.gov (United States)

    Doenst, Torsten; Strüning, Constanze; Moschovas, Alexandros; Gonzalez-Lopez, David; Essa, Yasin; Kirov, Hristo; Diab, Mahmoud; Faerber, Gloria

    2016-10-01

    For the year 2015, almost 19,000 published references can be found in PubMed when entering the search term "cardiac surgery". The last year has been again characterized by lively discussions in the fields where classic cardiac surgery and modern interventional techniques overlap. Lacking evidence in the field of coronary revascularization with either percutaneous coronary intervention or bypass surgery has been added. As in the years before, CABG remains the gold standard for the revascularization of complex stable triple-vessel disease. Plenty of new information has been presented comparing the conventional to transcatheter aortic valve implantation (TAVI) demonstrating similar short- and mid-term outcomes at high and low risk, but even a survival advantage with transfemoral TAVI at intermediate risk. In addition, there were many relevant and interesting other contributions from the purely operative arena. This review article will summarize the most pertinent publications in the fields of coronary revascularization, surgical treatment of valve disease, heart failure (i.e., transplantation and ventricular assist devices), and aortic surgery. While the article does not have the expectation of being complete and cannot be free of individual interpretation, it provides a condensed summary that is intended to give the reader "solid ground" for up-to-date decision-making in cardiac surgery.

  2. Cardiac hybrid imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gaemperli, Oliver [University Hospital Zurich, Cardiac Imaging, Zurich (Switzerland); University Hospital Zurich, Nuclear Cardiology, Cardiovascular Center, Zurich (Switzerland); Kaufmann, Philipp A. [University Hospital Zurich, Cardiac Imaging, Zurich (Switzerland); Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland)

    2014-05-15

    Hybrid cardiac single photon emission computed tomography (SPECT)/CT imaging allows combined assessment of anatomical and functional aspects of cardiac disease. In coronary artery disease (CAD), hybrid SPECT/CT imaging allows detection of coronary artery stenosis and myocardial perfusion abnormalities. The clinical value of hybrid imaging has been documented in several subsets of patients. In selected groups of patients, hybrid imaging improves the diagnostic accuracy to detect CAD compared to the single imaging techniques. Additionally, this approach facilitates functional interrogation of coronary stenoses and guidance with regard to revascularization procedures. Moreover, the anatomical information obtained from CT coronary angiography or coronary artery calcium scores (CACS) adds prognostic information over perfusion data from SPECT. The use of cardiac hybrid imaging has been favoured by the dissemination of dedicated hybrid systems and the release of dedicated image fusion software, which allow simple patient throughput for hybrid SPECT/CT studies. Further technological improvements such as more efficient detector technology to allow for low-radiation protocols, ultra-fast image acquisition and improved low-noise image reconstruction algorithms will be instrumental to further promote hybrid SPECT/CT in research and clinical practice. (orig.)

  3. Cardiac tissue engineering

    Directory of Open Access Journals (Sweden)

    MILICA RADISIC

    2005-03-01

    Full Text Available We hypothesized that clinically sized (1-5 mm thick,compact cardiac constructs containing physiologically high density of viable cells (~108 cells/cm3 can be engineered in vitro by using biomimetic culture systems capable of providing oxygen transport and electrical stimulation, designed to mimic those in native heart. This hypothesis was tested by culturing rat heart cells on polymer scaffolds, either with perfusion of culture medium (physiologic interstitial velocity, supplementation of perfluorocarbons, or with electrical stimulation (continuous application of biphasic pulses, 2 ms, 5 V, 1 Hz. Tissue constructs cultured without perfusion or electrical stimulation served as controls. Medium perfusion and addition of perfluorocarbons resulted in compact, thick constructs containing physiologic density of viable, electromechanically coupled cells, in contrast to control constructs which had only a ~100 mm thick peripheral region with functionally connected cells. Electrical stimulation of cultured constructs resulted in markedly improved contractile properties, increased amounts of cardiac proteins, and remarkably well developed ultrastructure (similar to that of native heart as compared to non-stimulated controls. We discuss here the state of the art of cardiac tissue engineering, in light of the biomimetic approach that reproduces in vitro some of the conditions present during normal tissue development.

  4. Activation of mitochondrial STAT-3 and reduced mitochondria damage during hypothermia treatment for post-cardiac arrest myocardial dysfunction.

    Science.gov (United States)

    Huang, Chien-Hua; Tsai, Min-Shan; Chiang, Chih-Yen; Su, Yu-Jen; Wang, Tzung-Dau; Chang, Wei-Tien; Chen, Huei-Wen; Chen, Wen-Jone

    2015-11-01

    While therapeutic hypothermia improves the outcomes of individuals in cardiac arrest, the hemodynamic responses and mechanisms which underlie hypothermia-induced cardioprotection are not fully understood. Therefore, we investigated the mechanism by which induced hypothermia preserves cardiac function and protects against mitochondrial damage following cardiac arrest. Cardiac arrest was induced in adult male Wistar rats by asphyxiation for 8.5 min. Following resuscitation, the animals were randomly assigned to a hypothermia (32 °C) or normothermia (37 °C) group. Monitoring results showed that cardiac output at the fourth hour after resuscitation was significantly better in rats treated with hypothermia when compared to rats treated with normothermia (P mitochondrial permeability transition pores occurred less frequently in the hypothermic group. While complex I/III activity in the electron transport reaction was damaged after cardiac arrest and resuscitation, the degree of injury was ameliorated by hypothermia treatment (P mitochondrial integrity and electron transport activity.

  5. THE NONSTATIONARITY OF GERMAN AGGREGATE OUTPUT

    NARCIS (Netherlands)

    ZELHORST, D; DEHAAN, J

    1993-01-01

    In this paper the stationarity of German per capita output for the period 1870-1989 is examined, using both a parametric and a non-parametric approach. The standard unit root tests and the scaled variogram suggest that German output is not stationary. Following the approach suggested by Perron (1989

  6. Practice Output in College Language Classroom

    Institute of Scientific and Technical Information of China (English)

    张岩

    2010-01-01

    <正>Practice output constitutes an indispensable part in second language learning.Relevant theories like"Interface Position"and"Comprehensible Output"are discussed in order to analyze in detail how this practice can actually facilitate acquisition and finally pave the way for communicative output—a goal all language learners are striving for.

  7. The Role of Output in Grammar Learning

    Institute of Scientific and Technical Information of China (English)

    尹莉; 段薇; 谢璐

    2014-01-01

    In China, English teachers tend to emphasize a lot on the importance of grammar learning because knowledge of gram⁃mar is the base of the competence of communication. This thesis just focuses on how output affects students ’grammar learning by analyzing the role of output in learning of English and the strategies of English learning.

  8. Multi-output programmable quantum processor

    OpenAIRE

    Yu, Yafei; Feng, Jian; Zhan, Mingsheng

    2002-01-01

    By combining telecloning and programmable quantum gate array presented by Nielsen and Chuang [Phys.Rev.Lett. 79 :321(1997)], we propose a programmable quantum processor which can be programmed to implement restricted set of operations with several identical data outputs. The outputs are approximately-transformed versions of input data. The processor successes with certain probability.

  9. DIST/AVC Out-Put Definition.

    Science.gov (United States)

    Wilkinson, Gene L.

    The first stage of development of a management information system for DIST/AVC (Division of Instructional Technology/Audio-Visual Center) is the definition of out-put units. Some constraints on the definition of output units are: 1) they should reflect goals of the organization, 2) they should reflect organizational structure and procedures, and…

  10. Output beam analysis of high power COIL

    Institute of Scientific and Technical Information of China (English)

    Deli Yu(于德利); Fengting Sang(桑凤亭); Yuqi Jin(金玉奇); Yizhu Sun(孙以珠)

    2003-01-01

    As the output power of a chemical oxygen iodine laser (COIL) increases, the output laser beam instabilityappears as the far-field beam spot drift and deformation for the large Fresnel number unstable resonator.In order to interpret this phenomenon, an output beam mode simulation code was developed with the fastFourier transform method. The calculation results show that the presence of the nonuniform gain in COILproduces a skewed output intensity distribution, which causes the mirror tilt and bulge due to the thermalexpansion. With the output power of COIL increases, the mirror surfaces, especially the back surface ofthe scraper mirror, absorb more and more heat, which causes the drift and deformation of far field beamspot seriously. The initial misalignment direction is an important factor for the far field beam spot driftingand deformation.

  11. Crop Insurance, Premium Subsidy and Agricultural Output

    Institute of Scientific and Technical Information of China (English)

    XU Jing-feng; LIAO Pu

    2014-01-01

    This paper studied the effects of crop insurance on agricultural output with an economic growth model. Based on Ramsey-Cass-Koopmans (RCK) model, a basic model of agriculture economic growth was developed. Extending the basic model to incorporate uncertainty and insurance mechanism, a risk model and a risk-insurance model were built to study the inlfuences of risk and crop insurance on agricultural output. Compared with the steady states of the three models, the following results are achieved:(i) agricultural output decreases if we introduce uncertainty into the risk-free model;(ii) crop insurance promotes agriculture economic growth if insurance mechanism is introduced into the risk model;(iii) premium subsidy constantly improves agricultural output. Our contribution is that we studied the effects of crop insurance and premium subsidy from the perspective of economic growth in a dynamic framework, and proved the output promotion of crop insurance theoretically.

  12. Indeterminacy of Spatiotemporal Cardiac Alternans

    CERN Document Server

    Zhao, Xiaopeng

    2007-01-01

    Cardiac alternans, a beat-to-beat alternation in action potential duration (at the cellular level) or in ECG morphology (at the whole heart level), is a marker of ventricular fibrillation, a fatal heart rhythm that kills hundreds of thousands of people in the US each year. Investigating cardiac alternans may lead to a better understanding of the mechanisms of cardiac arrhythmias and eventually better algorithms for the prediction and prevention of such dreadful diseases. In paced cardiac tissue, alternans develops under increasingly shorter pacing period. Existing experimental and theoretical studies adopt the assumption that alternans in homogeneous cardiac tissue is exclusively determined by the pacing period. In contrast, we find that, when calcium-driven alternans develops in cardiac fibers, it may take different spatiotemporal patterns depending on the pacing history. Because there coexist multiple alternans solutions for a given pacing period, the alternans pattern on a fiber becomes unpredictable. Usin...

  13. Case Report: Penetrating Cardiac Injury

    Directory of Open Access Journals (Sweden)

    Adem Grbolar

    2013-10-01

    Full Text Available Summary: Penetrating cardiac injurys caused by gunshots and penetrating tools have high mortality rates. The way of injury, how the cardiac area is effected and the presence of cardiac tamponadecauses mortality in different rates. However the better treatment quality of hospitals, increasingoperative techniques, and internel care unit quality has not been change during the years. Searching the literature, we want to present a 42 years old male patient whowas injured by knife and had a 1 cm skin wound on chest with cardiac tamponade. After sternotomy a 7 cm laseration was observed in heart. Cardioraphy was performed.

  14. Cardiac surgery for Kartagener syndrome.

    Science.gov (United States)

    Tkebuchava, T; von Segesser, L K; Niederhäuser, U; Bauersfeld, U; Turina, M

    1997-01-01

    Two patients (one girl, one boy) with Kartagener syndrome (situs inversus, bronchiectasis, sinusitis), despite pulmonary problems and associated congenital cardiac anomalies, were operated on at the ages of 4 years and 7 years, respectively. They had had previous palliative treatment at the age of 3 months and 1.3 years, respectively. Both postoperative periods after total correction were without significant complications. Long-term follow-up was available for 9 and 19 years, respectively, with no manifestations of heart insufficiency. Both patients are physically active, and neither requires cardiac medication. Patients with Kartagener syndrome and associated congenital cardiac anomalies can successfully undergo multiple cardiac operations with good long-term outcome.

  15. High output piezo/triboelectric hybrid generator.

    Science.gov (United States)

    Jung, Woo-Suk; Kang, Min-Gyu; Moon, Hi Gyu; Baek, Seung-Hyub; Yoon, Seok-Jin; Wang, Zhong-Lin; Kim, Sang-Woo; Kang, Chong-Yun

    2015-01-01

    Recently, piezoelectric and triboelectric energy harvesting devices have been developed to convert mechanical energy into electrical energy. Especially, it is well known that triboelectric nanogenerators have a simple structure and a high output voltage. However, whereas nanostructures improve the output of triboelectric generators, its fabrication process is still complicated and unfavorable in term of the large scale and long-time durability of the device. Here, we demonstrate a hybrid generator which does not use nanostructure but generates much higher output power by a small mechanical force and integrates piezoelectric generator into triboelectric generator, derived from the simultaneous use of piezoelectric and triboelectric mechanisms in one press-and-release cycle. This hybrid generator combines high piezoelectric output current and triboelectric output voltage, which produces peak output voltage of ~370 V, current density of ~12 μA · cm(-2), and average power density of ~4.44 mW · cm(-2). The output power successfully lit up 600 LED bulbs by the application of a 0.2 N mechanical force and it charged a 10 μF capacitor to 10 V in 25 s. Beyond energy harvesting, this work will provide new opportunities for developing a small, built-in power source in self-powered electronics such as mobile electronics.

  16. Relationship between stroke volume, cardiac output and filling of the heart during tilt

    DEFF Research Database (Denmark)

    Bundgaard-Nielsen, M.; Sorensen, H.; Dalsgaard, M.;

    2009-01-01

    %) in LVEDV because HR increased 3 bpm and CO decreased 0.5 l/min (ns). CONCLUSION: This study confirmed that SV and CO are maximal in resting, supine, healthy humans and decrease during HUT. However, 90 degrees HDT was associated with increased LVEDV and induced a reduction in SV Udgivelsesdato: 2009/11...

  17. Allometric scaling of decompression sickness risk in terrestrial mammals; cardiac output explains risk of decompression sickness

    Science.gov (United States)

    Fahlman, Andreas

    2017-02-01

    A probabilistic model was used to predict decompression sickness (DCS) outcome in pig (70 and 20 kg), hamster (100 g), rat (220 g) and mouse (20 g) following air saturation dives. The data set included 179 pig, 200 hamster, 360 rat, and 224 mouse exposures to saturation pressures ranging from 1.9–15.2 ATA and with varying decompression rates (0.9–156 ATA • min‑1). Single exponential kinetics described the tissue partial pressures (Ptiss) of N2: Ptiss =  ∫(Pamb – Ptiss) • τ‑1 dt, where Pamb is ambient N2 pressure and τ is a time constant. The probability of DCS [P(DCS)] was predicted from the risk function: P(DCS) = 1‑e‑r, where r = ∫(PtissN2 ‑ Thr ‑ Pamb) • Pamb–1 dt, and Thr is a threshold parameter. An equation that scaled τ with body mass included a constant (c) and an allometric scaling parameter (n), and the best model included n, Thr, and two c. The final model provided accurate predictions for 58 out of 61 dive profiles for pig, hamster, rat, and mouse. Thus, body mass helped improve the prediction of DCS risk in four mammalian species over a body mass range covering 3 orders of magnitude.

  18. Is pulmonary gas exchange during exercise in hypoxia impaired with the increase of cardiac output?

    DEFF Research Database (Denmark)

    Calbet, J.A.; Robach, P.; Lundby, C.

    2008-01-01

    -a)DO(2) is accentuated. Using the multiple inert gas elimination technique it has been shown that during exercise in acute hypoxia the contribution of ventilation-perfusion inequality to (A-a)DO(2) is rather small and in the absence of pulmonary edema intrapulmonary shunts can be ruled out. This implies...

  19. Evaluation of cerebral electrical activity and cardiac output after patent ductus arteriosus ligation in preterm infants.

    LENUS (Irish Health Repository)

    Leslie, A T F S

    2013-11-01

    To characterize and investigate the relationship between systemic blood flow and pre- and postoperative cerebral electrical activity in preterm neonates undergoing patent ductus arteriosus (PDA) ligation.

  20. Impact of extracorporeal blood flow rate on blood pressure, pulse rate and cardiac output during haemodialysis

    DEFF Research Database (Denmark)

    Schytz, Philip Andreas; Mace, Maria Lerche; Soja, Anne Merete Boas

    2015-01-01

    BACKGROUND: If blood pressure (BP) falls during haemodialysis (HD) [intradialytic hypotension (IDH)] a common clinical practice is to reduce the extracorporeal blood flow rate (EBFR). Consequently the efficacy of the HD (Kt/V) is reduced. However, only very limited knowledge on the effect of redu...

  1. Monitoring cardiac output during hyperbaric oxygen treatment of haemodynamically unstable patients

    DEFF Research Database (Denmark)

    Hansen, Marco Bo; Treschow, Frederik; Skielboe, Martin

    2013-01-01

    Patients suffering from necrotizing fasciitis (NF) are often haemodynamically unstable and require extended monitoring of cardiovascular parameters; yet this is limited during hyperbaric oxygen treatment (HBOT). We aimed to evaluate the use and safety of transoesophageal Doppler (TED) monitoring...

  2. Mechanisms of increase in cardiac output during acute weightlessness in humans

    DEFF Research Database (Denmark)

    Petersen, Lonnie G; Damgaard, Morten; Petersen, Johan Casper Grove;

    2011-01-01

    by parabolic flight increased CO by 1.7 ± 0.4 l/min (P ... in CO during acute 0 G in seated humans. A Bainbridge-like reflex could be the mechanism for the HR-induced increase in CO during 0 G in particular in supine subjects....

  3. High Output Cardiac Failure Resolving after Repair of AV Fistula in a Six-Month-Old

    OpenAIRE

    Uygar Teomete; Rubee Anne Gugol; Holly Neville; Ozgur Dandin; Ming-Lon Young

    2016-01-01

    Background. Acquired AVF in pediatrics are commonly caused by iatrogenic means, including arterial or venous punctures. These fistulae can cause great hemodynamic stress on the heart as soon as they are created. Case. A six-month-old 25-week gestation infant was referred for respiratory distress. Initial exam revealed tachypnea, tachycardia, and hypertension. There was a bruit noted on her left arm. An ultrasound showed an arteriovenous fistula. Its location, however, precluded intervention b...

  4. Sublingual nitroglycerin used in routine tilt testing provokes a cardiac output-mediated vasovagal response

    NARCIS (Netherlands)

    Gisolf, J.; Westerhof, B.E.; Dijk, N. van; Wesseling, K.H.; Wieling, W.; Karemaker, J.M.

    2004-01-01

    Objectives We set out to determine the effect of sublingual nitroglycerin (NTG), as used during routine tilt testing in patients with unexplained syncope, on hemodynamic characteristics and baroreflex control of heart rate (HR) and systemic vascular resistance (SVR). Background Nitroglycerin is used

  5. Estimation of cardiac output and total peripheral resistance in preterm infants by arterial waveform analysis.

    Science.gov (United States)

    Zhang, Ying; Chan, Gregory S H; Tracy, Mark B; Hinder, Murray; Redmond, Stephen J; Savkin, Andrey V; Lovell, Nigel H

    2013-01-01

    This study investigated whether arterial blood pressure waveform analysis could be useful for estimating left ventricular outflow (LVO) and total peripheral resistance (TPR) in preterm infants. A cohort of 27 infants were studied, with 89 measurements of left ventricular outflow (LVO) using Doppler echocardiography and arterial pressure using catheters, performed in 0, 12, 24 and 36 hours after birth. TPR was computed as mean arterial pressure divided by LVO. The diastolic decay rate (1/τ) was obtained via fitting an exponential function to the last one third of each arterial pulse, with the mean rate computed from 50 pulses selected from each infant. This decay rate was considered to be inversely related to TPR while positively related to LVO. The results of regression analysis have confirmed that the diastolic decay rate had significant positive and negative relationships with LVO and TPR respectively(r = 0.383, P = 0.0002 and r = -0.379, P = 0.0002 respectively). These preliminary results demonstrated the potential utility of arterial pressure waveform analysis for estimating LVO and TPR in preterm infants, but more advanced multi-parameter models may be needed to improve accuracy of the estimation.

  6. Effects of ventilation on cardiac output determined by inert gas rebreathing

    DEFF Research Database (Denmark)

    Damgaard, Morten; Norsk, Peter

    2005-01-01

    had no effects. CO was 1.0 +/- 0.2 l min(-1) higher when, rebreathing was performed after a forced expiration than following a normal tidal expiration. Serial determinations of CO required a 3-min interval between the measurements to avoid effects of recirculation of N(2)O. Changing RF from 15 to 30...... breaths min(-1) or adding serial dead space by up to 600 ml did not affect the determination of CO. In conclusion, the rebreathing procedure for determination of CO at rest should be performed following a normal tidal expiration with a rebreathing bag volume of between 1.5 and 2.5 l and with manoeuvres...

  7. Output Regulation of the Arneodo Chaotic System

    Directory of Open Access Journals (Sweden)

    Sundarapandian Vaidyanathan

    2010-08-01

    Full Text Available This paper solves the problem of regulating the output of the Arneodo chaotic system (1981, which is one of the paradigms of chaotic dynamical systems. Explicitly, using the state feedback control laws, the output of the Arneodo chaotic system is regulated so as to track constant reference signals as well as to track periodic reference signals. The control laws are derived using the regulator equations of Byrnes and Isidori (1990, which provide the solution of the output regulation problem for nonlinear control systems involving neutrally stable exosystem dynamics. Numerical results are shown to verify the results.

  8. Histamine induces postprandian tachycardia through a direct effect on cardiac H2-receptors in pythons

    DEFF Research Database (Denmark)

    Jensen, Nini Skovgaard; Møller, Kate; Gesser, Hans

    2009-01-01

    snakes histamine caused a systemic vasodilatation and a marked increase in heart rate and cardiac output mediated through a direct effect on H2-receptors. Our study strongly indicates that histamine regulates heart rate during the initial phase of digestion in pythons. This study describes a novel...

  9. Output Measures and Library Space Planning.

    Science.gov (United States)

    Lushington, Nolan

    1987-01-01

    Draws some initial connections between library performance measures and library space planning and collection management. Output measure surveys are suggested for establishing hierarchies of use and appropriate design of environments for housing the collection. Four references are listed. (MES)

  10. Scaling of global input-output networks

    Science.gov (United States)

    Liang, Sai; Qi, Zhengling; Qu, Shen; Zhu, Ji; Chiu, Anthony S. F.; Jia, Xiaoping; Xu, Ming

    2016-06-01

    Examining scaling patterns of networks can help understand how structural features relate to the behavior of the networks. Input-output networks consist of industries as nodes and inter-industrial exchanges of products as links. Previous studies consider limited measures for node strengths and link weights, and also ignore the impact of dataset choice. We consider a comprehensive set of indicators in this study that are important in economic analysis, and also examine the impact of dataset choice, by studying input-output networks in individual countries and the entire world. Results show that Burr, Log-Logistic, Log-normal, and Weibull distributions can better describe scaling patterns of global input-output networks. We also find that dataset choice has limited impacts on the observed scaling patterns. Our findings can help examine the quality of economic statistics, estimate missing data in economic statistics, and identify key nodes and links in input-output networks to support economic policymaking.

  11. Oil Refining Giants to Cut Output

    Institute of Scientific and Technical Information of China (English)

    Zhang Dingmin

    2002-01-01

    @@ China's refined oil product output rose slightly in the first five months of this year on strong demand,but the two biggest domestic producers plan to cut production rates in an attempt to bolster the sluggish price.

  12. OFFSHORE OIL OUTPUT MORE THAN SCHEDULED

    Institute of Scientific and Technical Information of China (English)

    1997-01-01

    @@ China Offshore Oil Nan Hai East Corp (CONHE) is one of four subsidiaries of the China National Offshore Oil Corp.The first-quarter output was an encouraging 220 000 tons more than the planned goal for that period.

  13. Memory-based parallel data output controller

    Science.gov (United States)

    Stattel, R. J.; Niswander, J. K. (Inventor)

    1984-01-01

    A memory-based parallel data output controller employs associative memories and memory mapping to decommutate multiple channels of telemetry data. The output controller contains a random access memory (RAM) which has at least as many address locations as there are channels. A word counter addresses the RAM which provides as it outputs an encoded peripheral device number and a MSB/LSB-first flag. The encoded device number and a bit counter address a second RAM which contains START and STOP flags to pick out the required bits from the specified word number. The LSB/MSB, START and STOP flags, along with the serial input digital data go to a control block which selectively fills a shift register used to drive the parallel data output bus.

  14. Coupling output of multichannel high power microwaves

    Science.gov (United States)

    Li, Guolin; Shu, Ting; Yuan, Chengwei; Zhang, Jun; Yang, Jianhua; Jin, Zhenxing; Yin, Yi; Wu, Dapeng; Zhu, Jun; Ren, Heming; Yang, Jie

    2010-12-01

    The coupling output of multichannel high power microwaves is a promising technique for the development of high power microwave technologies, as it can enhance the output capacities of presently studied devices. According to the investigations on the spatial filtering method and waveguide filtering method, the hybrid filtering method is proposed for the coupling output of multichannel high power microwaves. As an example, a specific structure is designed for the coupling output of S/X/X band three-channel high power microwaves and investigated with the hybrid filtering method. In the experiments, a pulse of 4 GW X band beat waves and a pulse of 1.8 GW S band microwave are obtained.

  15. Hypokalemia and sudden cardiac death

    DEFF Research Database (Denmark)

    Kjeldsen, Keld

    2010-01-01

    Worldwide, approximately three million people suffer sudden cardiac death annually. These deaths often emerge from a complex interplay of substrates and triggers. Disturbed potassium homeostasis among heart cells is an example of such a trigger. Thus, hypokalemia and, also, more transient...... of fatal arrhythmia and sudden cardiac death a patient is, the more attention should be given to the potassium homeostasis....

  16. The Danish Cardiac Rehabilitation Database

    DEFF Research Database (Denmark)

    Zwisler, Ann-Dorthe; Rossau, Henriette Knold; Nakano, Anne

    2016-01-01

    AIM OF DATABASE: The Danish Cardiac Rehabilitation Database (DHRD) aims to improve the quality of cardiac rehabilitation (CR) to the benefit of patients with coronary heart disease (CHD). STUDY POPULATION: Hospitalized patients with CHD with stenosis on coronary angiography treated with percutane...

  17. Biosynthesis of cardiac natriuretic peptides

    DEFF Research Database (Denmark)

    Goetze, Jens Peter

    2010-01-01

    . An inefficient post-translational prohormone maturation will also affect the biology of the cardiac natriuretic peptide system. This review aims at summarizing the myocardial synthesis of natriuretic peptides focusing on B-type natriuretic peptide, where new data has disclosed cardiac myocytes as highly...

  18. [Cardiac myxoma with cerebral metastases].

    Science.gov (United States)

    Bazin, A; Peruzzi, P; Baudrillard, J C; Pluot, M; Rousseaux, P

    1987-01-01

    A 56 year old woman developed multiple metastases in the cerebrum and cerebellum, four years after cardiac intervention on a left atrial myxoma. The absence of stroke is noteworthy. Multiple high density lesions with contrast enhancement were seen by CT scan, suggesting metastatic neoplasms. Histological examination confirmed the diagnosis of metastases of cardiac myxoma. Only four cases were recorded in the literature.

  19. Health Instruction Packages: Cardiac Anatomy.

    Science.gov (United States)

    Phillips, Gwen; And Others

    Text, illustrations, and exercises are utilized in these five learning modules to instruct nurses, students, and other health care professionals in cardiac anatomy and functions and in fundamental electrocardiographic techniques. The first module, "Cardiac Anatomy and Physiology: A Review" by Gwen Phillips, teaches the learner to draw…

  20. APPROXIMATE OUTPUT REGULATION FOR AFFINE NONLINEAR SYSTEMS

    Institute of Scientific and Technical Information of China (English)

    Yali DONG; Daizhan CHENG; Huashu QIN

    2003-01-01

    Output regulation for affine nonlinear systems driven by an exogenous signal is investigated in this paper. In the absence of the standard exosystem hypothesis, we assume availability of the instantaneous values of the exogenous signal and its first time-derivative for use in the control law.For affine nonlinear systems, the necessary and sufficient conditions of the solvability of approximate output regulation problem are obtained. The precise form of the control law is presented under some suitable assumptions.

  1. Pneumothorax in cardiac pacing

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard;

    2012-01-01

    AIM: To identify risk factors for pneumothorax treated with a chest tube after cardiac pacing device implantation in a population-based cohort.METHODS AND RESULTS: A nationwide cohort study was performed based on data on 28 860 patients from the Danish Pacemaker Register, which included all Danish...... patients who received their first pacemaker (PM) or cardiac resynchronization device from 1997 to 2008. Multiple logistic regression was used to estimate adjusted odds ratios (aOR) with 95% confidence intervals for the association between risk factors and pneumothorax treated with a chest tube. The median...... age was 77 years (25th and 75th percentile: 69-84) and 55% were male (n = 15 785). A total of 190 patients (0.66%) were treated for pneumothorax, which was more often in women [aOR 1.9 (1.4-2.6)], and in patients with age >80 years [aOR 1.4 (1.0-1.9)], a prior history of chronic obstructive pulmonary...

  2. Leadership in cardiac surgery.

    Science.gov (United States)

    Rao, Christopher; Patel, Vanash; Ibrahim, Michael; Ahmed, Kamran; Wong, Kathie A; Darzi, Ara; von Segesser, Ludwig K; Athanasiou, Thanos

    2011-06-01

    Despite the efficacy of cardiac surgery, less invasive interventions with more uncertain long-term outcomes are increasingly challenging surgery as first-line treatment for several congenital, degenerative and ischemic cardiac diseases. The specialty must evolve if it is to ensure its future relevance. More importantly, it must evolve to ensure that future patients have access to treatments with proven long-term effectiveness. This cannot be achieved without dynamic leadership; however, our contention is that this is not enough. The demands of a modern surgical career and the importance of the task at hand are such that the serendipitous emergence of traditional charismatic leadership cannot be relied upon to deliver necessary change. We advocate systematic analysis and strategic leadership at a local, national and international level in four key areas: Clinical Care, Research, Education and Training, and Stakeholder Engagement. While we anticipate that exceptional individuals will continue to shape the future of our specialty, the creation of robust structures to deliver collective leadership in these key areas is of paramount importance.

  3. Avaliação da correlação entre o dióxido de carbono expirado e o débito cardíaco em pacientes submetidos à cirurgia cardíaca com circulação extracorpórea Evaluación de la correlación entre el dióxido de carbono expirado y el débito cardíaco en pacientes sometidos a la cirugía cardíaca con circulación extracorpórea Correlation between end-tidal carbon dioxide levels and cardiac output during cardiac surgery with cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Karina Takesaki Miyaji

    2004-10-01

    reflects pulmonary blood perfusion, thus cardiac output (CO. This study aimed at evaluating the correlation between P ET CO2 levels and CO during cardiac surgery with cardiopulmonary bypass (CPB. METHODS: Participated in this study 25 patients submitted to coronary artery bypass grafting (CABG with CPB. End-tidal CO2 monitoring started after tracheal intubation. Cardiac output was determined by thermodilution with pulmonary artery catheter (Swan-Ganz. Carbon dioxide partial blood pressure (PaCO2 was obtained with arterial blood gases analysis. Studied parameters were evaluated in the following moments: immediately after general anesthesia induction, before cardiopulmonary bypass, at cardiopulmonary bypass completion and at surgery completion. RESULTS: Statistical analysis has not shown correlation between P ET CO2 and CO2, or between P ET CO2-PaCO2 gradient (Ga-eCO2 and CO. There has been correlation between P ET CO2, Ga-eCO2 and CO values variation as compared to baseline values before CPB, with loss of correlation after CPB until surgery completion. CONCLUSIONS: In this study, where patients submitted to cardiac surgery with CPB were evaluated, ventilation/perfusion changes throughout the procedure might have been the factors determining decreased correlation between cardiac output and end tidal CO2.

  4. Epo deficiency alters cardiac adaptation to chronic hypoxia.

    Science.gov (United States)

    El Hasnaoui-Saadani, Raja; Marchant, Dominique; Pichon, Aurélien; Escoubet, Brigitte; Pezet, Mylène; Hilfiker-Kleiner, Denise; Hoch, Melanie; Pham, Isabelle; Quidu, Patricia; Voituron, Nicolas; Journé, Clément; Richalet, Jean-Paul; Favret, Fabrice

    2013-04-01

    The involvement of erythropoietin in cardiac adaptation to acute and chronic (CHx) hypoxia was investigated in erythropoietin deficient transgenic (Epo-TAg(h)) and wild-type (WT) mice. Left (LV) and right ventricular functions were assessed by echocardiography and hemodynamics. HIF-1α, VEGF and Epo pathways were explored through RT-PCR, ELISA, Western blot and immunocytochemistry. Epo gene and protein were expressed in cardiomyocytes of WT mice in normoxia and hypoxia. Increase in blood hemoglobin, angiogenesis and functional cardiac adaptation occurred in CHx in WT mice, allowing a normal oxygen delivery (O2T). Epo deficiency induced LV hypertrophy, increased cardiac output (CO) and angiogenesis, but O2T remained lower than in WT mice. In CHx Epo-TAg(h) mice, LV hypertrophy, CO and O2T decreased. HIF-1α and Epo receptor pathways were depressed, suggesting that Epo-TAg(h) mice could not adapt to CHx despite activation of cardioprotective pathways (increased P-STAT-5/STAT-5). HIF/Epo pathway is activated in the heart of WT mice in hypoxia. Chronic hypoxia induced cardiac adaptive responses that were altered with Epo deficiency, failing to maintain oxygen delivery to tissues.

  5. Modelling of an oesophageal electrode for cardiac function tomography.

    Science.gov (United States)

    Tehrani, J Nasehi; Jin, C; McEwan, A L

    2012-01-01

    There is a need in critical care units for continuous cardiopulmonary monitoring techniques. ECG gated electrical impedance tomography is able to localize the impedance variations occurring during the cardiac cycle. This method is a safe, inexpensive and potentially fast technique for cardiac output imaging but the spatial resolution is presently low, particularly for central locations such as the heart. Many parameters including noise deteriorate the reconstruction result. One of the main obstacles in cardiac imaging at the heart location is the high impedance of lungs and muscles on the dorsal and posterior side of body. In this study we are investigating improvements of the measurement and initial conductivity estimation of the internal electrode by modelling an internal electrode inside the esophagus. We consider 16 electrodes connected around a cylindrical mesh. With the random noise level set near 0.05% of the signal we evaluated the Graz consensus reconstruction algorithm for electrical impedance tomography. The modelling and simulation results showed that the quality of the target in reconstructed images was improved by up to 5 times for amplitude response, position error, resolution, shape deformation and ringing effects with perturbations located in cardiac related positions when using an internal electrode.

  6. Modelling of an Oesophageal Electrode for Cardiac Function Tomography

    Directory of Open Access Journals (Sweden)

    J. Nasehi Tehrani

    2012-01-01

    Full Text Available There is a need in critical care units for continuous cardiopulmonary monitoring techniques. ECG gated electrical impedance tomography is able to localize the impedance variations occurring during the cardiac cycle. This method is a safe, inexpensive and potentially fast technique for cardiac output imaging but the spatial resolution is presently low, particularly for central locations such as the heart. Many parameters including noise deteriorate the reconstruction result. One of the main obstacles in cardiac imaging at the heart location is the high impedance of lungs and muscles on the dorsal and posterior side of body. In this study we are investigating improvements of the measurement and initial conductivity estimation of the internal electrode by modelling an internal electrode inside the esophagus. We consider 16 electrodes connected around a cylindrical mesh. With the random noise level set near 0.05% of the signal we evaluated the Graz consensus reconstruction algorithm for electrical impedance tomography. The modelling and simulation results showed that the quality of the target in reconstructed images was improved by up to 5 times for amplitude response, position error, resolution, shape deformation and ringing effects with perturbations located in cardiac related positions when using an internal electrode.

  7. Imaging findings of multiple infantile hepatic hemangioma associated with cardiac insufficiency

    Institute of Scientific and Technical Information of China (English)

    Jing-Jing Ye; Yin-Can Shao; Qiang Shu

    2014-01-01

    Background: Infantile hepatic hemangioma (IHH) as a benign liver tumor in infancy and childhood is commonly associated with high output cardiac failure. The present study aims to describe the imaging findings in a patient who was diagnosed as having multiple IHH with congestive cardiac insuffi ciency. Methods: The imaging findings and clinical manifestations of the patient with multiple IHH associated with cardiac insuffi ciency were retrospectively reviewed. Results: Ultrasonography showed multiple intrahepatic lesions with mixed echoes and markedly expanded hepatic veins and the inferior vena cava of the patient. Echocardiography revealed right heart insufficiency and pulmonary hypertension. Contrast-enhanced MRI showed early mild enhancement of lesions and more obvious delayed enhancement. The patient died after combined therapy of surgery and hormone. Conclusions: The imaging findings of multiple IHH associated with cardiac insufficiency are typical and diagnostic. Early imaging assessment may facilitate the diagnosis and treatment of the disease.

  8. Right atrial tamponade complicating cardiac operation: clinical, hemodynamic, and scintigraphic correlates

    Energy Technology Data Exchange (ETDEWEB)

    Bateman, T.; Gray, R.; Chaux, A.; Lee, M.; De Robertis, M.; Berman, D.; Matloff, J.

    1982-09-01

    Persistent bleeding into the pericardial space in the early hours after cardiac operation not uncommonly results in cardiac tamponade. Single chamber tamponade also might be expected, since in this setting the pericardium frequently contains firm blood clots localized to the area of active bleeding. However, this complication has received very little attention in the surgical literature. We are therefore providing documentation that isolated right atrial tamponade can occur as a complication of cardiac operation and that there exists a potential for misdiagnosis and hence incorrect treatment of this condition. Right atrial tamponade may be recognized by a combination of low cardiac output, low blood pressure, prominent neck veins, right atrial pressure in excess of pulmonary capillary wedge pressure and right ventricular end-diastolic pressure, and a poor response to plasma volume expansion. Findings on chest roentgenogram and gated wall motion scintigraphy may be highly suggestive. This review should serve to increase awareness of this complication and to provide some helpful diagnostic clues.

  9. Malignant hepatic epithelioid hemangioendothelioma with high-output heart failure: successful management of heart failure with transcatheter arterial chemoembolization.

    Science.gov (United States)

    Hsu, Chien-Yi; Liu, Yao-Chung; Li, Chung-Pin; Huang, Po-Hsun; Lin, Chin-Hsuan; Chao, Yee

    2014-06-01

    A 73-year-old woman was admitted to hospital because of progressive dyspnea on exertion. Computed tomography revealed a large hepatic tumor, which was proved to be a hepatic epithelioid hemangioendothelioma (EHE). Echocardiography demonstrated high cardiac output, for which the tumor was considered to be the leading cause. A transcatheter arterial chemoembolization (TACE) was performed sequentially at 1-month intervals to reduce the size of the hepatic tumor, and this temporarily improved the patient's cardiac condition and quality of life. In this case, we successfully used TACE in the treatment of hepatic EHE with high-output heart failure. TACE is a reasonable choice of treatment both for managing malignant hepatic tumors and resolving low systemic vascular resistance by embolization of the abnormal neoangiogenic vessels. Nevertheless, clinicians should be aware of the potential adverse effect of hepatic decompensation induced by TACE, especially when the tumor involvement is widespread and poorly preserved hepatic function is encountered.

  10. Physics of Cardiac Arrhythmogenesis

    Science.gov (United States)

    Karma, Alain

    2013-04-01

    A normal heartbeat is orchestrated by the stable propagation of an excitation wave that produces an orderly contraction. In contrast, wave turbulence in the ventricles, clinically known as ventricular fibrillation (VF), stops the heart from pumping and is lethal without prompt defibrillation. I review experimental, computational, and theoretical studies that have shed light on complex dynamical phenomena linked to the initiation, maintenance, and control of wave turbulence. I first discuss advances made to understand the precursor state to a reentrant arrhythmia where the refractory period of cardiac tissue becomes spatiotemporally disordered; this is known as an arrhythmogenic tissue substrate. I describe observed patterns of transmembrane voltage and intracellular calcium signaling that can contribute to this substrate, and symmetry breaking instabilities to explain their formation. I then survey mechanisms of wave turbulence and discuss novel methods that exploit electrical pacing stimuli to control precursor patterns and low-energy pulsed electric fields to control turbulence.

  11. Platelets and cardiac arrhythmia

    Directory of Open Access Journals (Sweden)

    Jonas S De Jong

    2010-12-01

    Full Text Available Sudden cardiac death remains one of the most prevalent modes of death in industrialized countries, and myocardial ischemia due to thrombotic coronary occlusion is its primary cause. The role of platelets in the occurrence of SCD extends beyond coronary flow impairment by clot formation. Here we review the substances released by platelets during clot formation and their arrhythmic properties. Platelet products are released from three types of platelet granules: dense core granules, alpha-granules, and platelet lysosomes. The physiologic properties of dense granule products are of special interest as a potential source of arrhythmic substances. They are released readily upon activation and contain high concentrations of serotonin, histamine, purines, pyrimidines, and ions such as calcium and magnesium. Potential arrhythmic mechanisms of these substances, e.g. serotonin and high energy phosphates, include induction of coronary constriction, calcium overloading, and induction of delayed after-depolarizations. Alpha-granules produce thromboxanes and other arachidonic acid products with many potential arrhythmic effects mediated by interference with cardiac sodium, calcium and potassium channels. Alpha-granules also contain hundreds of proteins that could potentially serve as ligands to receptors on cardiomyocytes. Lysosomal products probably do not have an important arrhythmic effect. Platelet products and ischemia can induce coronary permeability, thereby enhancing interaction with surrounding cardiomyocytes. Antiplatelet therapy is known to improve survival after myocardial infarction. Although an important part of this effect results from prevention of coronary clot formation, there is evidence to suggest that antiplatelet therapy also induces anti-arrhythmic effects during ischemia by preventing the release of platelet activation products.

  12. Mediastinitis after cardiac transplantation

    Directory of Open Access Journals (Sweden)

    Noedir A. G. Stolf

    2000-05-01

    Full Text Available OBJECTIVE: Assessment of incidence and behavior of mediastinitis after cardiac transplantation. METHODS: From 1985 to 1999, 214 cardiac transplantations were performed, 12 (5.6% of the transplanted patients developed confirmed mediastinitis. Patient's ages ranged from 42 to 66 years (mean of 52.3±10.0 years and 10 (83.3% patients were males. Seven (58.3% patients showed sternal stability on palpation, 4 (33.3% patients had pleural empyema, and 2 (16.7% patients did not show purulent secretion draining through the wound. RESULTS: Staphylococcus aureus was the infectious agent identified in the wound secretion or in the mediastinum, or both, in 8 (66.7% patients. Staphylococcus epidermidis was identified in 2 (16.7% patients, Enterococcus faecalis in 1 (8.3% patient, and the cause of mediastinitis could not be determined in 1 (8.3% patient. Surgical treatment was performed on an emergency basis, and the extension of the débridement varied with local conditions. In 2 (16.7% patients, we chose to leave the surgical wound open and performed daily dressings with granulated sugar. Total sternal resection was performed in only 1 (8.3% patient. Out of this series, 5 (41.7% patients died, and the causes of death were related to the infection. Autopsy revealed persistence of mediastinitis in 1 (8.3% patient. CONCLUSION: Promptness in diagnosing mediastinitis and precocious surgical drainage have changed the natural evolution of this disease. Nevertheless, observance of the basic precepts of prophylaxis of infection is still the best way to treat mediastinitis.

  13. Cardiac performance correlates of relative heart ventricle mass in amphibians.

    Science.gov (United States)

    Kluthe, Gregory J; Hillman, Stanley S

    2013-08-01

    This study used an in situ heart preparation to analyze the power output and stroke work of spontaneously beating hearts of four anurans (Rhinella marina, Lithobates catesbeianus, Xenopus laevis, Pyxicephalus edulis) and three urodeles (Necturus maculosus, Ambystoma tigrinum, Amphiuma tridactylum) that span a representative range of relative ventricle mass (RVM) found in amphibians. Previous research has documented that RVM correlates with dehydration tolerance and maximal aerobic capacity in amphibians. The power output (mW g(-1) ventricle mass) and stroke work (mJ g(-1) ventricle muscle mass) were independent of RVM and were indistinguishable from previously published results for fish and reptiles. RVM was significantly correlated with maximum power output (P max, mW kg(-1) body mass), stroke volume, cardiac output, afterload pressure (P O) at P max, and preload pressure (P I) at P max. P I at P max and P O at P max also correlated very closely with each other. The increases in both P I and P O at maximal power outputs in large hearts suggest that concomitant increases in blood volume and/or increased modulation of vascular compliance either anatomically or via sympathetic tone on the venous vasculature would be necessary to achieve P max in vivo. Hypotheses for variation in RVM and its concomitant increased P max in amphibians are developed.

  14. Response requirements as constraints on output.

    Science.gov (United States)

    Zeiler, M D; Buchman, I B

    1979-07-01

    Two experiments studied how added response requirements affected fixed-interval schedule performance. Experiment 1 involved tandem fixed-interval fixed-ratio schedules, and Experiment 2 studied conjunctive fixed-interval fixed-ratio schedules. In both, pigeons' output, defined as overall response rate or as responses during the interval, first increased and then decreased as the ratio was raised. With small ratio requirements, the frequency of reinforcement in time either did not change or decreased slightly. With progressively larger ratios, reinforcement frequency decreased consistently. Alternative explanations were discussed. The first, a reinforcement theory account, was that response strength is an increasing monotonic function of both the response requirement and reinforcement frequency, and the bitonic output function represents interacting effects. Increases in the response requirement accompanied by small changes in reinforcement frequency enhance output, but further increases result in large enough decrements in reinforcement frequency so that output is lowered. The second explanation does not view reinforcement as a basic process but, instead, derives from concepts of economics and conservation. Organisms allocate their behavior among alternatives so as to maximize value, where value is a function of the responses that can occur in a given situation under the set of restrictions imposed by particular schedules. One form of this theory explicitly predicts that output is a bitonic function of ratio requirements in simple ratio schedules. However, it was not clear that this model could explain the present effects involving joint ratio and interval schedule restrictions.

  15. Residual gravimetric method to measure nebulizer output.

    Science.gov (United States)

    Vecellio None, Laurent; Grimbert, Daniel; Bordenave, Joelle; Benoit, Guy; Furet, Yves; Fauroux, Brigitte; Boissinot, Eric; De Monte, Michele; Lemarié, Etienne; Diot, Patrice

    2004-01-01

    The aim of this study was to assess a residual gravimetric method based on weighing dry filters to measure the aerosol output of nebulizers. This residual gravimetric method was compared to assay methods based on spectrophotometric measurement of terbutaline (Bricanyl, Astra Zeneca, France), high-performance liquid chromatography (HPLC) measurement of tobramycin (Tobi, Chiron, U.S.A.), and electrochemical measurements of NaF (as defined by the European standard). Two breath-enhanced jet nebulizers, one standard jet nebulizer, and one ultrasonic nebulizer were tested. Output produced by the residual gravimetric method was calculated by weighing the filters both before and after aerosol collection and by filter drying corrected by the proportion of drug contained in total solute mass. Output produced by the electrochemical, spectrophotometric, and HPLC methods was determined after assaying the drug extraction filter. The results demonstrated a strong correlation between the residual gravimetric method (x axis) and assay methods (y axis) in terms of drug mass output (y = 1.00 x -0.02, r(2) = 0.99, n = 27). We conclude that a residual gravimetric method based on dry filters, when validated for a particular agent, is an accurate way of measuring aerosol output.

  16. Metoclopramide-induced cardiac arrest

    Directory of Open Access Journals (Sweden)

    Martha M. Rumore

    2011-11-01

    Full Text Available The authors report a case of cardiac arrest in a patient receiving intravenous (IV metoclopramide and review the pertinent literature. A 62-year-old morbidly obese female admitted for a gastric sleeve procedure, developed cardiac arrest within one minute of receiving metoclopramide 10 mg via slow intravenous (IV injection. Bradycardia at 4 beats/min immediately appeared, progressing rapidly to asystole. Chest compressions restored vital function. Electrocardiogram (ECG revealed ST depression indicative of myocardial injury. Following intubation, the patient was transferred to the intensive care unit. Various cardiac dysrrhythmias including supraventricular tachycardia (SVT associated with hypertension and atrial fibrillation occurred. Following IV esmolol and metoprolol, the patient reverted to normal sinus rhythm. Repeat ECGs revealed ST depression resolution without pre-admission changes. Metoclopramide is a non-specific dopamine receptor antagonist. Seven cases of cardiac arrest and one of sinus arrest with metoclopramide were found in the literature. The metoclopramide prescribing information does not list precautions or adverse drug reactions (ADRs related to cardiac arrest. The reaction is not dose related but may relate to the IV administration route. Coronary artery disease was the sole risk factor identified. According to Naranjo, the association was possible. Other reports of cardiac arrest, severe bradycardia, and SVT were reviewed. In one case, five separate IV doses of 10 mg metoclopramide were immediately followed by asystole repeatedly. The mechanism(s underlying metoclopramide’s cardiac arrest-inducing effects is unknown. Structural similarities to procainamide may play a role. In view of eight previous cases of cardiac arrest from metoclopramide having been reported, further elucidation of this ADR and patient monitoring is needed. Our report should alert clinicians to monitor patients and remain diligent in surveillance and

  17. Fetal cardiac rhabdomyoma: case report

    Directory of Open Access Journals (Sweden)

    Seyed Mostafa Ghavami

    2016-07-01

    Full Text Available Background: The primary manifestation of cardiac tumors in embryonic period is a very rare condition. Cardiac rhabdomyomas most frequently arise in the ventricular myocardium, they may also occur in the atria and the epicardial surface. In spite of its benign nature, the critical location of the tumor inside the heart can lead to lethal arrhythmias and chamber obstruction. Multiple rhabdomyomas are strongly associated with tuberous sclerosis which is associated with mental retardation and epilepsy of variable severity. Ultrasonography as a part of routine prenatal screening, is the best method for the diagnosis of cardiac rhabdomyomas. In the review of articles published in Iran, fetal cardiac rhabdomyoma was not reported. Case presentation: We report a case of cardiac rhabdomyoma on a 24-year-old gravid 1, referred to Day Medical Imaging Center for routine evaluation of fetal abnormalities at 31 weeks of her gestational age. Ultrasonographic examination displayed a homogenous echogenic mass (13×9mm, originating from the left ventricle of the fetal heart. It was a normal pregnancy without any specific complications. Other organs of the fetus were found normal and no cardiac abnormalities were appeared. No Pericardial fluid effusion was found. The parents did not have consanguineous marriage. They did not also have any specific disease such as tuberous sclerosis. Conclusion: The clinical features of cardiac rhabdomyomas vary widely, depending on the location, size, and number of tumors in the heart. Although cardiac rhabdomyoma is a benign tumor in many affected fetuses, an early prenatal diagnosis of the tumor is of great significance in making efficient planning and providing adequate follow up visits of the patients and the complications such as, heart failure and outlet obstruction of cardiac chambers.

  18. Epigenetic regulation in cardiac fibrosis

    Institute of Scientific and Technical Information of China (English)

    Li-Ming; Yu; Yong; Xu

    2015-01-01

    Cardiac fibrosis represents an adoptive response in the heart exposed to various stress cues. While resolution of the fibrogenic response heralds normalization of heart function, persistent fibrogenesis is usually associated with progressive loss of heart function and eventually heart failure. Cardiac fibrosis is regulated by a myriad of factors that converge on the transcription of genes encoding extracellular matrix proteins, a process the epigenetic machinery plays a pivotal role. In this minireview, we summarize recent advances regarding the epigenetic regulation of cardiac fibrosis focusing on the role of histone and DNA modifications and non-coding RNAs.

  19. Cardiac Involvement in Ankylosing Spondylitis

    Science.gov (United States)

    Ozkan, Yasemin

    2016-01-01

    Ankylosing spondylitis is one of the subgroup of diseases called “seronegative spondyloarthropathy”. Frequently, it affects the vertebral colon and sacroiliac joint primarily and affects the peripheral joints less often. This chronic, inflammatory and rheumatic disease can also affect the extraarticular regions of the body. The extraarticular affections can be ophthalmologic, cardiac, pulmonary or neurologic. The cardiac affection can be 2-10% in all patients. Cardiac complications such as left ventricular dysfunction, aortitis, aortic regurgitation, pericarditis and cardiomegaly are reviewed. PMID:27222669

  20. Acupuncture therapy related cardiac injury.

    Science.gov (United States)

    Li, Xue-feng; Wang, Xian

    2013-12-01

    Cardiac injury is the most serious adverse event in acupuncture therapy. The causes include needling chest points near the heart, the cardiac enlargement and pericardial effusion that will enlarge the projected area on the body surface and make the proper depth of needling shorter, and the incorrect needling method of the points. Therefore, acupuncture practitioners must be familiar with the points of the heart projected area on the chest and the correct needling methods in order to reduce the risk of acupuncture therapy related cardiac injury.

  1. Problems in Modelling Charge Output Accelerometers

    Directory of Open Access Journals (Sweden)

    Tomczyk Krzysztof

    2016-12-01

    Full Text Available The paper presents major issues associated with the problem of modelling change output accelerometers. The presented solutions are based on the weighted least squares (WLS method using transformation of the complex frequency response of the sensors. The main assumptions of the WLS method and a mathematical model of charge output accelerometers are presented in first two sections of this paper. In the next sections applying the WLS method to estimation of the accelerometer model parameters is discussed and the associated uncertainties are determined. Finally, the results of modelling a PCB357B73 charge output accelerometer are analysed in the last section of this paper. All calculations were executed using the MathCad software program. The main stages of these calculations are presented in Appendices A−E.

  2. Effect of water intake on sweat output

    Directory of Open Access Journals (Sweden)

    K. V. Mani

    1961-07-01

    Full Text Available The effect of drinking volumes of water in excess of normal requirement at a given time on sweat output was studied under two conditions of body activity namely marching and standing, and two conditions of exposure namely sun and shade. It was found that (1drinking large volumes of water causes a significant and appreciable increase in sweat output, of the order of 0.8 gm/kg/hr; and (2 this increase is very nearly the same under all the conditions studied. It is suggested that changes in tonicity of the plasma may be the main cause for this phenomenon. It is also pointed out that this increased sweat output is not a loss to the body.

  3. PV output smoothing with energy storage.

    Energy Technology Data Exchange (ETDEWEB)

    Ellis, Abraham; Schoenwald, David Alan

    2012-03-01

    This report describes an algorithm, implemented in Matlab/Simulink, designed to reduce the variability of photovoltaic (PV) power output by using a battery. The purpose of the battery is to add power to the PV output (or subtract) to smooth out the high frequency components of the PV power that that occur during periods with transient cloud shadows on the PV array. The control system is challenged with the task of reducing short-term PV output variability while avoiding overworking the battery both in terms of capacity and ramp capability. The algorithm proposed by Sandia is purposely very simple to facilitate implementation in a real-time controller. The control structure has two additional inputs to which the battery can respond. For example, the battery could respond to PV variability, load variability or area control error (ACE) or a combination of the three.

  4. Pole placement with constant gain output feedback

    Science.gov (United States)

    Sridhar, B.; Lindorff, D. P.

    1972-01-01

    Given a linear time invariant multivariable system with m inputs and p outputs, it was shown that p closed loop poles of the system can be preassigned arbitrarily using constant gain output feedback provided (A circumflex, B circumflex) is controllable. These data show that if (A circumflex, B circumflex, C circumflex) is controllable and observable, and Rank B circumflex = m, Rank C circumflex = p, then max (m,p) poles of the system can be assigned arbitarily using constant gain output feedback. Further, it is shown that in some cases more than max (m,p) poles can be arbitrarily assigned. A least square design technique is outlined to approximate the desired pole locations when it is not possible to place all the poles.

  5. An Analysis of Output on English Vocabulary Acquisition

    Institute of Scientific and Technical Information of China (English)

    曾娅妮

    2014-01-01

    Output Hypothesis was proposed by Swain in 1985, her Output Hypothesis is regarded as the most important and in-fluential one. However, few studies research and analyze the effect of output on vocabulary acquisition. The findings of this study suggest the importance of output in vocabulary acquisition. Furthermore, in the interactive mode output can help learners acquire vocabulary.

  6. Normal cardiac function in mice with supraphysiological cardiac creatine levels.

    Science.gov (United States)

    Santacruz, Lucia; Hernandez, Alejandro; Nienaber, Jeffrey; Mishra, Rajashree; Pinilla, Miguel; Burchette, James; Mao, Lan; Rockman, Howard A; Jacobs, Danny O

    2014-02-01

    Creatine and phosphocreatine levels are decreased in heart failure, and reductions in myocellular phosphocreatine levels predict the severity of the disease and portend adverse outcomes. Previous studies of transgenic mouse models with increased creatine content higher than two times baseline showed the development of heart failure and shortened lifespan. Given phosphocreatine's role in buffering ATP content, we tested the hypothesis whether elevated cardiac creatine content would alter cardiac function under normal physiological conditions. Here, we report the creation of transgenic mice that overexpress the human creatine transporter (CrT) in cardiac muscle under the control of the α-myosin heavy chain promoter. Cardiac transgene expression was quantified by qRT-PCR, and human CrT protein expression was documented on Western blots and immunohistochemistry using a specific anti-CrT antibody. High-energy phosphate metabolites and cardiac function were measured in transgenic animals and compared with age-matched, wild-type controls. Adult transgenic animals showed increases of 5.7- and 4.7-fold in the content of creatine and free ADP, respectively. Phosphocreatine and ATP levels were two times as high in young transgenic animals but declined to control levels by the time the animals reached 8 wk of age. Transgenic mice appeared to be healthy and had normal life spans. Cardiac morphometry, conscious echocardiography, and pressure-volume loop studies demonstrated mild hypertrophy but normal function. Based on our characterization of the human CrT protein expression, creatine and phosphocreatine content, and cardiac morphometry and function, these transgenic mice provide an in vivo model for examining the therapeutic value of elevated creatine content for cardiac pathologies.

  7. Multiple myeloma presenting with high-output heart failure and improving with anti-angiogenesis therapy: two case reports and a review of the literature

    Directory of Open Access Journals (Sweden)

    Robin Jason

    2008-07-01

    Full Text Available Abstract Introduction Common manifestations of multiple myeloma include osteolytic lesions, cytopenias, hypercalcemia, and renal insufficiency. Patients may also exhibit heart failure which is often associated with either past therapy or cardiac amyloidosis. A less recognized mechanism is high-output heart failure. Diuretic therapy in this setting has little efficacy in treating the congested state. Furthermore, effective pharmacotherapy has not been established. We report two patients with multiple myeloma and high-output heart failure who failed diuretic therapy. The patients were given dexamethasone in conjunction with lenalidomide and thalidomide, respectively. Shortly thereafter, each patient demonstrated a significant improvement in symptoms. This is the first report of successful treatment of multiple myeloma-induced high-output failure via the utilization of these agents. Case presentation Two patients with multiple myeloma were evaluated for volume overload. The first was a 50-year-old man with refractory disease. Magnetic resonance imaging demonstrated diffuse marrow replacement throughout the pelvis. Cardiac catheterization conveyed elevated filling pressures and a cardiac output of 15 liters/minute. He quickly decompensated and required mechanical ventilation. The second patient was a 61-year-old man recently diagnosed with multiple myeloma and volume overload. Skeletal survey demonstrated numerous lytic lesions throughout the pelvis. His cardiac catheterization also conveyed elevated filling pressures and a cardiac output of 10 liters/minute. Neither patient responded to diuretic therapy and they were subsequently started on dexamethasone plus lenalidomide and thalidomide, respectively. The first patient's brisk diuresis allowed for extubation within 48 hours after the first dose. He had a net negative fluid balance of 15 liters over 10 days. The second patient also quickly diuresed and on repeat cardiac catheterization, his cardiac

  8. Reliability and Energy Output of Bifacial Modules

    Energy Technology Data Exchange (ETDEWEB)

    Van Aken, B.B.; Jansen, M.J.; Dekker, N.J.J. [ECN Solar Energy, Petten (Netherlands)

    2013-06-15

    Although flash tests under standard test conditions yields lower power due to transmittance of the back sheet, bifacial modules are expected to outperform their monofacial equivalents in terms of yearly energy output in the field. We compare flash tests for bifacial modules with and without a light scattering panel directly behind the modules: 3% more power output is obtained. We also report on the damp-heat reliability of modules with transparent back sheet. Finally we will present the results of an outdoor study comparing modules with transparent back sheet and modules with state-of-the-art AR coating on the front glass.

  9. Input/Output Subroutine Library Program

    Science.gov (United States)

    Collier, James B.

    1988-01-01

    Efficient, easy-to-use program moved easily to different computers. Purpose of NAVIO, Input/Output Subroutine Library, provides input/output package of software for FORTRAN programs that is portable, efficient, and easy to use. Implemented as hierarchy of libraries. At bottom is very small library containing only non-portable routines called "I/O Kernel." Design makes NAVIO easy to move from one computer to another, by simply changing kernel. NAVIO appropriate for software system of almost any size wherein different programs communicate through files.

  10. Output filters for AC adjustable speed drives

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Hanigovszki, Norbert; Landkildehus, Jorn, Jorn

    2007-01-01

    -phase applications the occurrence of common-mode (CM) voltage is inherent due to asymmetrical output pulses [1]. Consequently, several secondary effects arise at the inverter's output: high-frequency conducted and radiated emissions, leakage current, motor insulation stress due to wave reflection [2], bearing stress......The standard industrial solution for adjustable speed drives (ASD) is the use of induction motors (IM) fed by voltage-source inverters (VSI). The inverter generates a pulsewidth modulated (PWM) voltage, with dv/dt values of about 6 kV/¿s or even more. In three-leg inverters for three...

  11. Use of cardiac biomarkers in neonatology.

    Science.gov (United States)

    Vijlbrief, Daniel C; Benders, Manon J N L; Kemperman, Hans; van Bel, Frank; de Vries, Willem B

    2012-10-01

    Cardiac biomarkers are used to identify cardiac disease in term and preterm infants. This review discusses the roles of natriuretic peptides and cardiac troponins. Natriuretic peptide levels are elevated during atrial strain (atrial natriuretic peptide (ANP)) or ventricular strain (B-type natriuretic peptide (BNP)). These markers correspond well with cardiac function and can be used to identify cardiac disease. Cardiac troponins are used to assess cardiomyocyte compromise. Affected cardiomyocytes release troponin into the bloodstream, resulting in elevated levels of cardiac troponin. Cardiac biomarkers are being increasingly incorporated into clinical trials as indicators of myocardial strain. Furthermore, cardiac biomarkers can possibly be used to guide therapy and improve outcome. Natriuretic peptides and cardiac troponins are potential tools in the diagnosis and treatment of neonatal disease that is complicated by circulatory compromise. However, clear reference ranges need to be set and validation needs to be carried out in a population of interest.

  12. Recent developments in cardiac pacing.

    Science.gov (United States)

    Rodak, D J

    1995-10-01

    Indications for cardiac pacing continue to expand. Pacing to improve functional capacity, which is now common, relies on careful patient selection and technical improvements, such as complex software algorithms and diagnostic capabilities.

  13. Robotic Applications in Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    Alan P. Kypson

    2008-11-01

    Full Text Available Traditionally, cardiac surgery has been performed through a median sternotomy, which allows the surgeon generous access to the heart and surrounding great vessels. As a paradigm shift in the size and location of incisions occurs in cardiac surgery, new methods have been developed to allow the surgeon the same amount of dexterity and accessibility to the heart in confined spaces and in a less invasive manner. Initially, long instruments without pivot points were used, however, more recent robotic telemanipulation systems have been applied that allow for improved dexterity, enabling the surgeon to perform cardiac surgery from a distance not previously possible. In this rapidly evolving field, we review the recent history and clinical results of using robotics in cardiac surgery.

  14. Cardiac effects of 3-iodothyronamine: a new aminergic system modulating cardiac function.

    Science.gov (United States)

    Chiellini, Grazia; Frascarelli, Sabina; Ghelardoni, Sandra; Carnicelli, Vittoria; Tobias, Sandra C; DeBarber, Andrea; Brogioni, Simona; Ronca-Testoni, Simonetta; Cerbai, Elisabetta; Grandy, David K; Scanlan, Thomas S; Zucchi, Riccardo

    2007-05-01

    3-Iodothyronamine T1AM is a novel endogenous thyroid hormone derivative that activates the G protein-coupled receptor known as trace anime-associated receptor 1 (TAAR1). In the isolated working rat heart and in rat cardiomyocytes, T1AM produced a reversible, dose-dependent negative inotropic effect (e.g., 27+/-5, 51+/-3, and 65+/-2% decrease in cardiac output at 19, 25, and 38 microM concentration, respectively). An independent negative chronotropic effect was also observed. The hemodynamic effects of T1AM were remarkably increased in the presence of the tyrosine kinase inhibitor genistein, whereas they were attenuated in the presence of the tyrosine phosphatase inhibitor vanadate. No effect was produced by inhibitors of protein kinase A, protein kinase C, calcium-calmodulin kinase II, phosphatidylinositol-3-kinase, or MAP kinases. Tissue cAMP levels were unchanged. In rat ventricular tissue, Western blot experiments with antiphosphotyrosine antibodies showed reduced phosphorylation of microsomal and cytosolic proteins after perfusion with synthetic T1AM; reverse transcriptase-polymerase chain reaction experiments revealed the presence of transcripts for at least 5 TAAR subtypes; specific and saturable binding of [125I]T1AM was observed, with a dissociation constant in the low micromolar range (5 microM); and endogenous T1AM was detectable by tandem mass spectrometry. In conclusion, our findings provide evidence for the existence of a novel aminergic system modulating cardiac function.

  15. Cardiac manifestations in systemic sclerosis

    Institute of Scientific and Technical Information of China (English)

    Sevdalina; Lambova

    2014-01-01

    Primary cardiac involvement, which develops as a direct consequence of systemic sclerosis(SSc), may manifest as myocardial damage, fibrosis of the conduction system, pericardial and, less frequently, as valvular disease. In addition, cardiac complications in SSc may develop as a secondary phenomenon due to pulmonary arterial hypertension and kidney pathology. The prevalence of primary cardiac involvement in SSc is variable and difficult to determine because of the diversity of cardiac manifestations, the presence of subclinical periods, the type of diagnostic tools applied, and the diversity of patient populations. When clinically manifested, cardiac involvement is thought to be an important prognostic factor. Profound microvascular disease is a pathognomonic feature of SSc, as both vasospasm and structural alterations are present. Such alterations are thought to predict macrovascular atherosclerosis over time. There are contradictory reports regarding the prevalence of atherosclerosis in SSc. According to some authors, the prevalence of atherosclerosis of the large epicardial coronary arteries is similar to that of the general population, in contrast with other rheumatic diseases such as rheumatoid arthritis and systemic lupus erythematosus. However, the level of inflammation in SSc is inferior. Thus, the atherosclerotic process may not be as aggressive and not easily detectable in smaller studies. Echocardiography(especially tissue Doppler imaging), single-photon emission computed tomography, magnetic resonance imaging and cardiac computed tomography are sensitive techniques for earlier detection of both structural and functional scleroderma-related cardiac pathologies. Screening for subclinical cardiac involvement via modern, sensitive tools provides an opportunity for early diagnosis and treatment, which is of crucial importance for a positive outcome.

  16. Cardiac transplantation in Friedreich ataxia.

    Science.gov (United States)

    Yoon, Grace; Soman, Teesta; Wilson, Judith; George, Kristen; Mital, Seema; Dipchand, Anne I; McCabe, Jane; Logan, William; Kantor, Paul

    2012-09-01

    In this article, we describe a 14-year-old boy with a confirmed diagnosis of Friedreich ataxia who underwent cardiac transplantation for left ventricular failure secondary to dilated cardiomyopathy with restrictive physiology. His neurological status prior to transplantation reflected early signs of neurological disease, with evidence of dysarthria, weakness, mild gait impairment, and limb ataxia. We review the ethical issues considered during the process leading to the decision to offer cardiac transplantation.

  17. Cardiac Transplantation in Friedreich Ataxia

    OpenAIRE

    Yoon, Grace; Soman, Teesta; Wilson, Judith; George, Kristen; Mital, Seema; Dipchand, Anne I; McCabe, Jane; Logan, William; Kantor, Paul

    2012-01-01

    In this paper, we describe a 14-year-old boy with a confirmed diagnosis of Friedreich ataxia who underwent cardiac transplantation for left ventricular failure secondary to dilated cardiomyopathy with restrictive physiology. His neurological status prior to transplantation reflected early signs of neurologic disease, with evidence of dysarthria, weakness, mild gait impairment, and limb ataxia. We review the ethical issues considered during the process leading to the decision to offer cardiac ...

  18. Research Output, Socialization, and the Biglan Model.

    Science.gov (United States)

    Creswell, John W.; Bean, John P.

    1981-01-01

    A test of the Biglan model of faculty subcultures using measures of research output and tests of the model controlling for the effects of faculty socialization are described. The Biglan model is found to be valid, and the distinctiveness of the Biglan groups appears to increase with the socialization of faculty into subject areas. (Author/MLW)

  19. Predicting Color Output of Additive Manufactured Parts

    DEFF Research Database (Denmark)

    Eiríksson, Eyþór Rúnar; Pedersen, David Bue; Aanæs, Henrik

    2015-01-01

    In this paper we address the colorimetric performance of a multicolor additive manufacturing process. A method on how to measure and characterize color performance of said process is presented. Furthermore, a method on predicting the color output is demonstrated, allowing for previsualization...

  20. Explaining output volatility: The case of taxation

    DEFF Research Database (Denmark)

    Posch, Olaf

    the second moment of output growth rates without (long-run) effects on the first moment. Taking the model to the data, we exploit observed heterogeneity patterns to estimate effects of tax rates on macro volatility using panel estimation, explicitly modeling the unobserved variance process. We find a strong...

  1. Analysis of variance for model output

    NARCIS (Netherlands)

    Jansen, M.J.W.

    1999-01-01

    A scalar model output Y is assumed to depend deterministically on a set of stochastically independent input vectors of different dimensions. The composition of the variance of Y is considered; variance components of particular relevance for uncertainty analysis are identified. Several analysis of va

  2. Smoothing the output from a DAC

    Science.gov (United States)

    Wagner, C.

    1980-01-01

    Circuit smooths stepped waveform from analog-to-digital converter without appreciable phase shift between stepped input signal and smoothed output signal and without any effect from stepping rate. Waveform produced is suitable for driving controls used in manufacturing processes, aerospace systems, and automobiles.

  3. Turbo decoding using two soft output values

    Institute of Scientific and Technical Information of China (English)

    李建平; 潘申富; 梁庆林

    2004-01-01

    It is well known that turbo decoding always begins from the first component decoder and supposes that the apriori information is "0" at the first iterative decoding. To alternatively start decoding at two component decoders, we can gain two soft output values for the received observation of an input bit. It is obvious that two soft output values comprise more sufficient extrinsic information than only one output value obtained in the conventional scheme since different start points of decoding result in different combinations of the a priori information and the input codewords with different symbol orders due to the permutation of an interleaver. Summarizing two soft output values for erery bit before making hard decisions, we can correct more errors due to their complement. Consequently, turbo codes can achieve better error correcting performance than before in this way. Simulation results show that the performance of turbo codes using the novel proposed decoding scheme can get a growing improvement with the increment of SNR in general compared to the conventional scheme. When the bit error probability is 10-5, the proposed scheme can achieve 0.5 dB asymptotic coding gain or so under the given simulation conditions.

  4. What shapes output of policy reform?

    DEFF Research Database (Denmark)

    Carlsen, Kirsten

    This thesis deals with the factors shaping forest policy output during the stages implementation and bases its main message on empirical findings from the forestry sector in Ghana. Policy and institutional factors are important underlying causes for deforestation, especially in the tropics. Forest...

  5. Fast output-sensitive matrix multiplication

    DEFF Research Database (Denmark)

    Jacob, Riko; Stöckel, Morten

    2015-01-01

    We consider the problem of multiplying two $U \\times U$ matrices $A$ and $C$ of elements from a field $\\F$. We present a new randomized algorithm that can use the known fast square matrix multiplication algorithms to perform fewer arithmetic operations than the current state of the art for output...

  6. Fast Output-sensitive Matrix Multiplication

    DEFF Research Database (Denmark)

    Jacob, Riko; Stöckel, Morten

    2015-01-01

    We consider the problem of multiplying two $U \\times U$ matrices $A$ and $C$ of elements from a field $\\F$. We present a new randomized algorithm that can use the known fast square matrix multiplication algorithms to perform fewer arithmetic operations than the current state of the art for output...

  7. Input-output, expandable-parity network

    Science.gov (United States)

    Mckevitt, J. F., III

    1974-01-01

    Large-scale integrated circuit generates and checks parity of four eight-bit registers. In addition, circuit will indicate by output signal whether parity error exists. Circuit can also generate or check parity of words up to 32 bits. This is done by making appropriate internal wiring connections on the large-scale integrated chip.

  8. Capital Power:From Input to Output

    Institute of Scientific and Technical Information of China (English)

    You Wanlong; Alice

    2009-01-01

    @@ After thirty yeas "going out" of China overseas investment,we learn from our failed lessons and also successful experience.Chinese enterprises are now standing at a new starting point of "going out".China is transforming from "capital input power" to "capital output power".

  9. On optimal output regulation for linear systems

    NARCIS (Netherlands)

    Saberi, Ali; Stoorvogel, Anton A.; Sannuti, Peddapullaiah; Shi, Guoyong

    2003-01-01

    The classical output regulation problem formulation for linear systems has a number of shortcomings; among them a primary one is that it does not take into account the transient response. Although this problem has been studied since the 1970s, a complete picture has not emerged yet. We formulate and

  10. On output regulation for linear systems

    NARCIS (Netherlands)

    Saberi, Ali; Stoorvogel, Anton A.; Sannuti, Peddapullaiah

    2001-01-01

    For both continuous- and discrete-time systems, we revisit the output regulation problem for linear systems. We generalize the problem formulation in order � to expand the class of reference or disturbance signals, � to utilize the derivative or feedforward information of reference signals wheneve

  11. Monetary policy and regional output in Brazil

    Directory of Open Access Journals (Sweden)

    Rafael Rockenbach da Silva Guimarães

    2014-03-01

    Full Text Available This work presents an analysis of whether the effects of the Brazilian monetary policy on regional outputs are symmetric. The strategy developed combines the techniques of principal component analysis (PCA to decompose the variables that measure regional economic activity into common and region-specific components and vector autoregressions (VAR to observe the behavior of these variables in response to monetary policy shocks. The common component responds to monetary policy as expected. Additionally, the idiosyncratic components of the regions showed no impact of monetary policy. The main finding of this paper is that the monetary policy responses on regional output are symmetrical when the regional output decomposition is performed, and the responses are asymmetrical when this decomposition is not performed. Therefore, performing the regional output decomposition corroborates the economic intuition that monetary policy has no impact on region-specific issues. Once monetary policy affects the common component of the regional economic activity and does not impact its idiosyncratic components, it can be considered symmetrical.

  12. Output Dynamics, Technology, and Public Investment

    NARCIS (Netherlands)

    Duarte Bom, P.R.; Heijdra, B.J.; Ligthart, J.E.

    2010-01-01

    The paper studies the dynamic output effects of public infrastructure investment in a small open economy. We develop an overlapping generations model that includes a production externality of public capital and a wealth effect on labor supply. Public capital enters the firm's production function und

  13. Minimum output entropy of Gaussian channels

    CERN Document Server

    Lloyd, S; Maccone, L; Pirandola, S; Garcia-Patron, R

    2009-01-01

    We show that the minimum output entropy for all single-mode Gaussian channels is additive and is attained for Gaussian inputs. This allows the derivation of the channel capacity for a number of Gaussian channels, including that of the channel with linear loss, thermal noise, and linear amplification.

  14. [Stem cells and cardiac regeneration].

    Science.gov (United States)

    Perez Millan, Maria Ines; Lorenti, Alicia

    2006-01-01

    Stem cells are defined by virtue of their functional attributes: absence of tissue specific differentitated markers, capable of proliferation, able to self-maintain the population, able to produce a large number of differentiated, functional progeny, able to regenerate the tissue after injury. Cell therapy is an alternative for the treatment of several diseases, like cardiac diseases (cell cardiomyoplasty). A variety of stem cells could be used for cardiac repair: from cardiac and extracardiac sources. Each cell type has its own profile of advantages, limitations, and practicability issues in specific clinical settings. Differentiation of bone marrow stem cells to cardiomyocyte-like cells have been observed under different culture conditions. The presence of resident cardiac stem cell population capable of differentiation into cardiomyocyte or vascular lineage suggests that these cells could be used for cardiac tissue repair, and represent a great promise for clinical application. Stem cells mobilization by cytokines may also offer a strategy for cardiac regeneration. The use of stem cells (embryonic and adult) may hold the key to replacing cells lost in many devastating diseases. This potential benefit is a major focus for stem cell research.

  15. Cardiac Regeneration and Stem Cells.

    Science.gov (United States)

    Zhang, Yiqiang; Mignone, John; MacLellan, W Robb

    2015-10-01

    After decades of believing the heart loses the ability to regenerate soon after birth, numerous studies are now reporting that the adult heart may indeed be capable of regeneration, although the magnitude of new cardiac myocyte formation varies greatly. While this debate has energized the field of cardiac regeneration and led to a dramatic increase in our understanding of cardiac growth and repair, it has left much confusion in the field as to the prospects of regenerating the heart. Studies applying modern techniques of genetic lineage tracing and carbon-14 dating have begun to establish limits on the amount of endogenous regeneration after cardiac injury, but the underlying cellular mechanisms of this regeneration remained unclear. These same studies have also revealed an astonishing capacity for cardiac repair early in life that is largely lost with adult differentiation and maturation. Regardless, this renewed focus on cardiac regeneration as a therapeutic goal holds great promise as a novel strategy to address the leading cause of death in the developed world.

  16. Cardiac imaging. A multimodality approach

    Energy Technology Data Exchange (ETDEWEB)

    Thelen, Manfred [Johannes Gutenberg University Hospital, Mainz (Germany); Erbel, Raimund [University Hospital Essen (Germany). Dept. of Cardiology; Kreitner, Karl-Friedrich [Johannes Gutenberg University Hospital, Mainz (Germany). Clinic and Polyclinic for Diagnostic and Interventional Radiology; Barkhausen, Joerg (eds.) [University Hospital Schleswig-Holstein, Luebeck (Germany). Dept. of Radiology and Nuclear Medicine

    2009-07-01

    An excellent atlas on modern diagnostic imaging of the heart Written by an interdisciplinary team of experts, Cardiac Imaging: A Multimodality Approach features an in-depth introduction to all current imaging modalities for the diagnostic assessment of the heart as well as a clinical overview of cardiac diseases and main indications for cardiac imaging. With a particular emphasis on CT and MRI, the first part of the atlas also covers conventional radiography, echocardiography, angiography and nuclear medicine imaging. Leading specialists demonstrate the latest advances in the field, and compare the strengths and weaknesses of each modality. The book's second part features clinical chapters on heart defects, endocarditis, coronary heart disease, cardiomyopathies, myocarditis, cardiac tumors, pericardial diseases, pulmonary vascular diseases, and diseases of the thoracic aorta. The authors address anatomy, pathophysiology, and clinical features, and evaluate the various diagnostic options. Key features: - Highly regarded experts in cardiology and radiology off er image-based teaching of the latest techniques - Readers learn how to decide which modality to use for which indication - Visually highlighted tables and essential points allow for easy navigation through the text - More than 600 outstanding images show up-to-date technology and current imaging protocols Cardiac Imaging: A Multimodality Approach is a must-have desk reference for cardiologists and radiologists in practice, as well as a study guide for residents in both fields. It will also appeal to cardiac surgeons, general practitioners, and medical physicists with a special interest in imaging of the heart. (orig.)

  17. Recurrent late cardiac tamponade following cardiac surgery : a deceiving and potentially lethal complication

    NARCIS (Netherlands)

    Harskamp, Ralf E.; Meuzelaar, Jacobus J.

    2010-01-01

    Background - Cardiac tamponade, characterized by inflow obstruction of the heart chambers by extracardiac compression, is a potentially lethal complication following cardiac surgery. Case report - We present a case of recurrent cardiac tamponade following valve surgery. At first presentation, diagno

  18. Attenuated muscle metaboreflex-induced increases in cardiac function in hypertension.

    Science.gov (United States)

    Sala-Mercado, Javier A; Spranger, Marty D; Abu-Hamdah, Rania; Kaur, Jasdeep; Coutsos, Matthew; Stayer, Douglas; Augustyniak, Robert A; O'Leary, Donal S

    2013-11-15

    Sympathoactivation may be excessive during exercise in subjects with hypertension, leading to increased susceptibility to adverse cardiovascular events, including arrhythmias, infarction, stroke, and sudden cardiac death. The muscle metaboreflex is a powerful cardiovascular reflex capable of eliciting marked increases in sympathetic activity during exercise. We used conscious, chronically instrumented dogs trained to run on a motor-driven treadmill to investigate the effects of hypertension on the mechanisms of the muscle metaboreflex. Experiments were performed before and 30.9 ± 4.2 days after induction of hypertension, which was induced via partial, unilateral renal artery occlusion. After induction of hypertension, resting mean arterial pressure was significantly elevated from 98.2 ± 2.6 to 141.9 ± 7.4 mmHg. The hypertension was caused by elevated total peripheral resistance. Although cardiac output was not significantly different at rest or during exercise after induction of hypertension, the rise in cardiac output with muscle metaboreflex activation was significantly reduced in hypertension. Metaboreflex-induced increases in left ventricular function were also depressed. These attenuated cardiac responses caused a smaller metaboreflex-induced rise in mean arterial pressure. We conclude that the ability of the muscle metaboreflex to elicit increases in cardiac function is impaired in hypertension, which may contribute to exercise intolerance.

  19. Risk factors and the effect of cardiac resynchronization therapy on cardiac and non-cardiac mortality in MADIT-CRT

    DEFF Research Database (Denmark)

    Perkiomaki, Juha S; Ruwald, Anne-Christine; Kutyifa, Valentina;

    2015-01-01

    causes, 108 (63.9%) deemed cardiac, and 61 (36.1%) non-cardiac. In multivariate analysis, increased baseline creatinine was significantly associated with both cardiac and non-cardiac deaths [hazard ratio (HR) 2.97, P ...AIMS: To understand modes of death and factors associated with the risk for cardiac and non-cardiac deaths in patients with cardiac resynchronization therapy with implantable cardioverter-defibrillator (CRT-D) vs. implantable cardioverter-defibrillator (ICD) therapy, which may help clarify...... the action and limitations of cardiac resynchronization therapy (CRT) in relieving myocardial dysfunction. METHODS AND RESULTS: In Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT), during 4 years of follow-up, 169 (9.3%) of 1820 patients died of known...

  20. [Calpains and cardiac diseases].

    Science.gov (United States)

    Perrin, C; Vergely, C; Rochette, L

    2004-09-01

    Calpains are a large family of cytosolic cysteine proteases composed of at least fourteen distinct isoforms. The family can be divided into two groups on the basis of distribution: ubiquitous and tissue-specific. Our current knowledge about calpains properties apply mainly to the ubiquitous isozymes, micro- and milli-calpain (classic calpains). These forms are activated after autolysis. Translocation and subsequent interactions with phospholipids of these enzymes increase their activity. Calpains are able to cleave a subset of substrates, as enzymes, structural and signalling proteins. Cardiac pathologies, such as heart failure, atrial fibrillation or clinical states particularly ischemia reperfusion, are associated with an increase of cytosolic calcium and in this regards, calpain activation has been evoked as one of the mediators leading to myocardial damage. Calpain activities have been shown to be increased in hearts experimentally subjected to ischemia reperfusion or during hypertrophy, but also in atrial tissue harvested from patients suffering from atrial fibrillations. These activities have been related to an increase of the proteolysis of different myocardial components, particularly, troponins, which are major regulators of the contraction of cardiomyocytes. Moreover, recent works have demonstrated that calpains are involved in the development of myocardial cell death by necrosis or apoptosis.

  1. Cardiac Imaging System

    Science.gov (United States)

    1990-01-01

    Although not available to all patients with narrowed arteries, balloon angioplasty has expanded dramatically since its introduction with an estimated further growth to 562,000 procedures in the U.S. alone by 1992. Growth has fueled demand for higher quality imaging systems that allow the cardiologist to be more accurate and increase the chances of a successful procedure. A major advance is the Digital Cardiac Imaging (DCI) System designed by Philips Medical Systems International, Best, The Netherlands and marketed in the U.S. by Philips Medical Systems North America Company. The key benefit is significantly improved real-time imaging and the ability to employ image enhancement techniques to bring out added details. Using a cordless control unit, the cardiologist can manipulate images to make immediate assessment, compare live x-ray and roadmap images by placing them side-by-side on monitor screens, or compare pre-procedure and post procedure conditions. The Philips DCI improves the cardiologist's precision by expanding the information available to him.

  2. Chronic fatigue syndrome: illness severity, sedentary lifestyle, blood volume and evidence of diminished cardiac function.

    Science.gov (United States)

    Hurwitz, Barry E; Coryell, Virginia T; Parker, Meela; Martin, Pedro; Laperriere, Arthur; Klimas, Nancy G; Sfakianakis, George N; Bilsker, Martin S

    2009-10-19

    The study examined whether deficits in cardiac output and blood volume in a CFS (chronic fatigue syndrome) cohort were present and linked to illness severity and sedentary lifestyle. Follow-up analyses assessed whether differences in cardiac output levels between CFS and control groups were corrected by controlling for cardiac contractility and TBV (total blood volume). The 146 participants were subdivided into two CFS groups based on symptom severity data, severe (n=30) and non-severe (n=26), and two healthy non-CFS control groups based on physical activity, sedentary (n=58) and non-sedentary (n=32). Controls were matched to CFS participants using age, gender, ethnicity and body mass. Echocardiographic measures indicated that the severe CFS participants had 10.2% lower cardiac volume (i.e. stroke index and end-diastolic volume) and 25.1% lower contractility (velocity of circumferential shortening corrected by heart rate) than the control groups. Dual tag blood volume assessments indicated that the CFS groups had lower TBV, PV (plasma volume) and RBCV (red blood cell volume) than control groups. Of the CFS subjects with a TBV deficit (i.e. > or = 8% below ideal levels), the mean+/-S.D. percentage deficit in TBV, PV and RBCV were -15.4+/-4.0, -13.2+/-5.0 and -19.1+/-6.3% respectively. Lower cardiac volume levels in CFS were substantially corrected by controlling for prevailing TBV deficits, but were not affected by controlling for cardiac contractility levels. Analyses indicated that the TBV deficit explained 91-94% of the group differences in cardiac volume indices. Group differences in cardiac structure were offsetting and, hence, no differences emerged for left ventricular mass index. Therefore the findings indicate that lower cardiac volume levels, displayed primarily by subjects with severe CFS, were not linked to diminished cardiac contractility levels, but were probably a consequence of a co-morbid hypovolaemic condition. Further study is needed to address

  3. Prevalence of nursing diagnosis of decreased cardiac output and the predictive value of defining characteristics in patients under evaluation for heart transplant Prevalencia del diagnóstico de enfermería de disminución del gasto cardíaco y valor predictivo de las características definidoras en pacientes en fase de evaluación para trasplante cardíaco Prevalência do diagnóstico de enfermagem de débito cardíaco diminuído e valor preditivo das características definidoras em pacientes em avaliação para transplante cardíaco

    Directory of Open Access Journals (Sweden)

    Lígia Neres Matos

    2012-04-01

    Full Text Available The purposes of the study were to identify the prevalence of defining characteristics (DC of decreased cardiac output (DCO in patients with cardiac insufficiency under evaluation for heart transplantation, and to ascertain the likelihood of defining characteristics being predictive factors for the existence of reduction in cardiac output. Data was obtained by retrospective documental analysis of the clinical records of right-sided heart catheterizations in 38 patients between 2004 and 2009. The results showed that 71.1% of the patients had decreased cardiac output (measured by cardiac index. The majority of the NANDA-International defining characteristics for DCO were more frequent in individuals with reduced cardiac index levels. The study emphasizes the odds ratio (OR for increased Systemic Vascular Resistance of OR=4.533, of the third heart sound with OR=3.429 and the reduced ejection fraction with OR=2.850. By obtaining the predictive values for the defining characteristics the study identifies them as diagnostic indicators of decreased cardiac output.El estudio tiene como objetivos identificar la prevalencia de las características definitorias de la disminución del gasto cardíaco (DGC en pacientes con insuficiencia cardíaca (IC en evaluación para el trasplante de corazón y ver la probabilidad de las características definitorias sean factores predictivos de la existencia de una disminución del gasto cardíaco. Los datos se obtuvieron mediante el análisis documental retrospectivo de historias clínicas de cateterismo cordiaco derecho en 38 pacientes con insuficiencia cardíaca en la evaluación para el trasplante de corazón entre 2004 y 2009. Los resultados mostraron que el 71% de los pacientes habían reducido el gasto cardíaco (medido por el índice cardíaco. La mayoría de las características definitorias de la NANDA-International para el DGC fueron más frecuentes en individuos con índice cardíaco reducido. Los aspectos m

  4. Use of nitric oxide in thoracic surgery for a high risk cardiac patient

    Directory of Open Access Journals (Sweden)

    Vishal Garg

    2014-01-01

    Full Text Available Nitric oxide (NO is a selective pulmonary vasodilator especially in the presence of pulmonary artery hypertension. With right ventricle (RV dysfunction, inhaled NO may increase RV ejection fraction and cardiac output. The main advantage of NO over intravenous therapy is its inability to decrease systemic pressure thereby maintaining the coronary perfusion pressure and the myocardial perfusion. In this case report, we discuss the use of NO in a routine thoracic surgery patient suffering with severe left ventricular dysfunction and a potential candidate for a very high cardiac risk.

  5. Nitroglycerin reduces augmentation index and central blood pressure independent of effects on cardiac preload

    Institute of Scientific and Technical Information of China (English)

    Mike; Saddon; Karen; McNeil; Philip; Chowienczyk

    2009-01-01

    Objective To determine whether reduction in central pressure augmentation and central systolic blood pressure by nitroglycerine (NTG) results from effects on pre-load or is due to arterial dilation. Methods We compared effects of NTG with those of lower body negative pressure (LBNP). Hemodynamic measurements were made at rest,during LBNP (10,20 and 30 mmHg,each for 15 min) and after NTG (10,30 and 100 μg/min,each dose for 15 min) in ten healthy volunteers. Cardiac pre-load,stroke volume and cardiac output w...

  6. Catecholamine and volume therapy for cardiac surgery in Germany--results from a postal survey.

    Directory of Open Access Journals (Sweden)

    Christoph Sponholz

    Full Text Available Management of cardiac surgery patients is a very standardized procedure in respective local institutions. Yet only very limited evidence exists concerning optimal indication, safety and efficacy of hemodynamic monitoring catecholamine and fluid therapy.Between April and May 2013, all 81 German anaesthesia departments involved in cardiac surgery care were asked to participate in a questionnaire addressing the institutional specific current practice in hemodynamic monitoring, catecholamine and volume therapy.51 (63% questionnaires were completed and returned. All participating centers used basic hemodynamic monitoring (i.e. invasive arterial blood pressure and central venous pressure, supplemented by transesophageal echocardiography. Pulmonary arterial catheter and calibrated trend monitoring devices were also routinely available. In contrast, non-calibrated trend monitoring and esophageal doppler ultrasound devices were not commonly in use. Cerebral oximetry is increasingly emerging, but lacks clear indications. The majority of patients undergoing cardiac surgery, especially in university hospitals, required catecholamines during perioperative care, In case of low cardiac output syndrome, dobutamine (32%, epinephrine (30% or phosphodiesterase inhibitors (8% were first choice. In case of hypotension following vasoplegia, norepinephrine (96% represented the most common catecholamine. 88% of the participating centers reported regular use of colloid fluids, with hydroxyethyl starches (HES being first choice (64%.Choice of hemodynamic monitoring is homogenous throughout German centers treating cardiac surgery patients. Norepinephrine is the first line catecholamine in cases of decrease in peripheral vascular resistance. However, catecholamine choice for low cardiac output syndrome varies considerably. HES was the primary colloid used for fluid resuscitation. After conduct of this survey, HES use was restricted by European regulatory authorities in

  7. Cooperative linear output regulation for networked systems by dynamic measurement output feedback

    Science.gov (United States)

    Li, Shaobao; Feng, Gang; Wang, Juan; Luo, Xiaoyuan; Guan, Xinping

    2016-04-01

    This paper investigates the cooperative linear output regulation problem of a class of heterogeneous networked systems with a common reference input but with different disturbances for individual nodes. A novel distributed control law is presented based on dynamic measurement output feedback. It is shown that the overall networked closed-loop control system is asymptotically stable and the output regulation errors asymptotically approach zero as time goes to infinity under a sufficient and necessary condition. Finally, a numerical example is provided to demonstrate the effectiveness of the proposed control law.

  8. Dying from cardiac tamponade

    Directory of Open Access Journals (Sweden)

    Powari Manish

    2007-09-01

    Full Text Available Abstract Background To determine the causes of cardiac tamponade (CT, focussing especially on haemopericardium (HP, as a terminal mode of death, within a 430,000 rural English population. Methods Our hospital mortuary register and, all postmortem reports between 1995 and 2004 inclusive, were interrogated for patients dying of CT or HP. The causes of CT/HP and selected morphological characteristics were then determined. Results 14,368 postmortems were performed in this period: of these, 461 patients died of CT. Three cases were due to non-haemorrhagic pericardial effusion. HP accounted for the remaining 458 cases of which, five were post-traumatic, 311 followed rupture of an acute myocardial infarction (RAMI, 138 after intra-pericardial rupture of dissecting ascending aortic aneurysms (RD3A and four were due to miscellaneous causes. HP was more commonly due to RAMI. Men tended to die from RAMI or RD3A earlier than women. RAMI or RD3A were commoner in men Two thirds of RAMI were associated with coronary artery thrombosis. Anterior free wall rupture was commonest overall, and in women, but posterior free wall rupture was commoner in men. The volume of intrapericardial blood in RAMI (mean = 440 ml and RD3A (mean = 498 ml varied between 150 and 1000 ml: intrapericardial blood volume was greater in men than in women dying from either RAMI or RD3A. Conclusion At postmortem, CT is most often related to HP, attributable to either RAMI or intrapericardial RD3A. Post-traumatic and other causes of CT are infrequent.

  9. Patch in Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    Alireza Alizadeh Ghavidel

    2014-06-01

    Full Text Available Introduction: Excessive bleeding presents a risk for the patient in cardiovascular surgery. Local haemostatic agents are of great value to reduce bleeding and related complications. TachoSil (Nycomed, Linz, Austria is a sterile, haemostatic agent that consists of an equine collagen patchcoated with human fibrinogen and thrombin. This study evaluated the safety and efficacy of TachoSil compared to conventional technique.Methods: Forty-two patients scheduled for open heart surgeries, were entered to this study from August 2010 to May 2011. After primary haemostatic measures, patients divided in two groups based on surgeon’s judgment. Group A: 20 patients for whom TachoSil was applied and group B: 22 patients that conventional method using Surgicel (13 patients or wait and see method (9 cases, were performed in order to control the bleeding. In group A, 10 patients were male with mean age of 56.95±15.67 years and in group B, 9 cases were male with mean age of 49.95±14.41 years. In case group 70% (14/20 of the surgeries were redo surgeries versus 100% (22/22 in control group.Results: Baseline characteristics were similar in both groups. In TachoSil group 75% of patients required transfusion versus 90.90% in group B (P=0.03.Most transfusions consisted of packed red blood cell; 2±1.13 units in group A versus 3.11±1.44 in group B (P=0.01, however there were no significant differences between two groups regarding the mean total volume of intra and post-operative bleeding. Re-exploration was required in 10% in group A versus 13.63% in group B (P=0.67.Conclusion: TachoSil may act as a superior alternative in different types of cardiac surgery in order to control the bleeding and therefore reducing transfusion requirement.

  10. RMB Appreciation, Output Growth, and Inflation

    Institute of Scientific and Technical Information of China (English)

    YONGWEI; CHEN; DONG; LI

    2013-01-01

    Following Dibooglu and Kutan(2005),we construct a structural VAR model to investigate the impact of RMB(the Chinese currency)appreciation on growth and inflation in China.The empirical results show that RMB appreciation has negative effects on output growth and inflation while neither effect is statistically significant.However,exchange rate shocks are important in the fluctuations of output growth and inflation.We also simulate the scenario of a sharp currency appreciation compared to the gradual approach adopted by the Chinese government.In the counterfactual analysis we find that a sharp appreciation would lead to more violent shocks in economic growth and inflation compared to the gradual approach.

  11. UFO - The Universal FeynRules Output

    CERN Document Server

    Degrande, Céline; Fuks, Benjamin; Grellscheid, David; Mattelaer, Olivier; Reiter, Thomas

    2011-01-01

    We present a new model format for automatized matrix-element generators, the so- called Universal FeynRules Output (UFO). The format is universal in the sense that it features compatibility with more than one single generator and is designed to be flexible, modular and agnostic of any assumption such as the number of particles or the color and Lorentz structures appearing in the interaction vertices. Unlike other model formats where text files need to be parsed, the information on the model is encoded into a Python module that can easily be linked to other computer codes. We then describe an interface for the Mathematica package FeynRules that allows for an automatic output of models in the UFO format.

  12. Solar Power Station Output Inverter Control Design

    OpenAIRE

    Bauer, J.; Lettl, J.

    2011-01-01

    The photovoltaic applications spreads in these days fast, therefore they also undergo great development. Because the amount of the energy obtained from the panel depends on the surrounding conditions, as intensity of the sun exposure or the temperature of the solar array, the converter must be connected to the panel output. The Solar system equipped with inverter can supply small loads like notebooks, mobile chargers etc. in the places where the supplying network is not present. Or the system...

  13. Probabilistic Output Analysis by Program Manipulation

    DEFF Research Database (Denmark)

    Rosendahl, Mads; Kirkeby, Maja Hanne

    2015-01-01

    function as a possibly uncomputable expression in an intermediate language. This program is then analyzed, transformed, and approximated. The result is a closed form expression that computes an over approximation of the output probability distribution for the program. We focus on programs where...... the possible input follows a known probability distribution. Tests in programs are not assumed to satisfy the Markov property of having fixed branching probabilities independently of previous history....

  14. Rapid Output Growth of Special Acrylic Esters

    Institute of Scientific and Technical Information of China (English)

    Wang Lianzhi

    2007-01-01

    @@ Acrylic esters are usually classified into general-purpose varieties and special varieties. The production and application of general-purpose varieties is already quite matured in the world and their output growth tends to be flat. Owing to the development of coatings, electronics, automobiles,textiles, printing and construction sectors, especially the application of radiation curing technology in various sectors, special acrylic esters have developed rapidly.

  15. Validação de conteúdo das atuais e de novas características definidoras do diagnóstico de enfermagem débito cardíaco diminuído Validación de contenido de las actuales y nuevas características que definen el diagnostico de enfermería: disminución del gasto cardíaco Content validation of current and new defining characteristics of the nursing diagnosis: decreased cardiac output

    Directory of Open Access Journals (Sweden)

    Juliana de Lima Lopes

    2010-01-01

    encuentran presentes en la NANDA-I y, 41 (51,9% fueron consideradas como irrelevantes para este diagnóstico, siendo que ocho están listadas en la NANDA-I. CONCLUSIÓN: Las características definidoras listadas actualmente en la clasificación de la Taxonomía de la NANDA-I no abarcan completamente el diagnóstico de enfermería: disminución del gasto cardíaco.OBJECTIVE: To validate the content defining characteristics of the currently approved and of those identified through reviewing the literature, for the nursing diagnosis: decreased cardiac output. METHODS: Is a content validation study using the model proposed by Fehring. The defining characteristics were validated by 18 experts (eight doctors and ten nurses, using the five points Likert scale and according to the following classification: scores higher than 0.80 were considered as the main features; those with weight between 0, 50 and 0.79 as secondary; and, those with average less than or equal to 0.50 as irrelevant. RESULTS: Of 79 defining characteristics investigated, 38 (48.1% were validated, among which 17 were present in NANDA-I, and 41 (51.9% were considered as irrelevant to this diagnosis, of these, eight are listed in NANDA-I. CONCLUSION: The defining characteristics currently listed in the NANDA-I classification taxonomy do not completely cover the nursing diagnosis: decreased cardiac output.

  16. Solar Power Station Output Inverter Control Design

    Directory of Open Access Journals (Sweden)

    J. Bauer

    2011-04-01

    Full Text Available The photovoltaic applications spreads in these days fast, therefore they also undergo great development. Because the amount of the energy obtained from the panel depends on the surrounding conditions, as intensity of the sun exposure or the temperature of the solar array, the converter must be connected to the panel output. The Solar system equipped with inverter can supply small loads like notebooks, mobile chargers etc. in the places where the supplying network is not present. Or the system can be used as a generator and it shall deliver energy to the supply network. Each type of the application has different requirements on the converter and its control algorithm. But for all of them the one thing is common – the maximal efficiency. The paper focuses on design and simulation of the low power inverter that acts as output part of the whole converter. In the paper the design of the control algorithm of the inverter for both types of inverter application – for islanding mode and for operation on the supply grid – is discussed. Attention is also paid to the design of the output filter that should reduce negative side effects of the converter on the supply network.

  17. Structured output tracking guided by keypoint matching

    Science.gov (United States)

    Fang, Zhiwen; Cao, Zhiguo; Xiao, Yang

    2016-10-01

    Current keypoint-based trackers are widely used in object tracking system because of their robust capability against scale, rotation and so on. However, when these methods are applied in tracking 3D target in a forward-looking image sequences, the tracked point usually shifts away from the correct position as time increases. In this paper, to overcome the tracked point drifting, structured output tracking is used to track the target point with its surrounding information based on Haar-like features. First, around the tracked point in the last frame, a local patch is cropped to extract Haar-like features. Second, using a structured output SVM framework, a prediction function is learned in a larger radius to directly estimate the patch transformation between frames. Finally, during tracking the prediction function is applied to search the best location in a new frame. In order to achieve the robust tracking in real time, keypoint matching is adopted to coarsely locate the searched field in the whole image before using the structured output tracking. Experimentally, we show that our algorithm is able to outperform state-of-the-art keypoint-based trackers.

  18. How Basal Ganglia Outputs Generate Behavior

    Directory of Open Access Journals (Sweden)

    Henry H. Yin

    2014-01-01

    Full Text Available The basal ganglia (BG are a collection of subcortical nuclei critical for voluntary behavior. According to the standard model, the output projections from the BG tonically inhibit downstream motor centers and prevent behavior. A pause in the BG output opens the gate for behavior, allowing the initiation of actions. Hypokinetic neurological symptoms, such as inability to initiate actions in Parkinson’s disease, are explained by excessively high firing rates of the BG output neurons. This model, widely taught in textbooks, is contradicted by recent electrophysiological results, which are reviewed here. In addition, I also introduce a new model, based on the insight that behavior is a product of closed loop negative feedback control using internal reference signals rather than sensorimotor transformations. The nervous system is shown to be a functional hierarchy comprising independent controllers occupying different levels, each level controlling specific variables derived from its perceptual inputs. The BG represent the level of transition control in this hierarchy, sending reference signals specifying the succession of body orientations and configurations. This new model not only explains the major symptoms in movement disorders but also generates a number of testable predictions.

  19. Nuclear imaging in cardiac amyloidosis

    Energy Technology Data Exchange (ETDEWEB)

    Glaudemans, A.W.J.M.; Slart, R.H.J.A.; Veltman, N.C.; Dierckx, R.A.J.O. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Hanzeplein 1, P.O. Box 30001, Groningen (Netherlands); Zeebregts, C.J. [University Medical Center Groningen, Department of Surgery (Division of Vascular Surgery), Groningen (Netherlands); Tio, R.A. [University Medical Center Groningen, Department of Cardiology, Groningen (Netherlands); Hazenberg, B.P.C. [University Medical Center Groningen, Department of Rheumatology and Clinical Immunology, Groningen (Netherlands)

    2009-04-15

    Amyloidosis is a disease characterized by depositions of amyloid in organs and tissues. It can be localized (in just one organ) or systemic. Cardiac amyloidosis is a debilitating disease and can lead to arrhythmias, deterioration of heart function and even sudden death. We reviewed PubMed/Medline, without time constraints, on the different nuclear imaging modalities that are used to visualize myocardial amyloid involvement. Several SPECT tracers have been used for this purpose. The results with these tracers in the evaluation of myocardial amyloidosis and their mechanisms of action are described. Most clinical evidence was found for the use of {sup 123}I-MIBG. Myocardial defects in MIBG activity seem to correlate well with impaired cardiac sympathetic nerve endings due to amyloid deposits. {sup 123}I-MIBG is an attractive option for objective evaluation of cardiac sympathetic level and may play an important role in the indirect measurement of the effect of amyloid myocardial infiltration. Other, less sensitive, options are {sup 99m}Tc-aprotinin for imaging amyloid deposits and perhaps {sup 99m}Tc-labelled phosphate derivatives, especially in the differential diagnosis of the aetiology of cardiac amyloidosis. PET tracers, despite the advantage of absolute quantification and higher resolution, are not yet well evaluated for the study of cardiac amyloidosis. Because of these advantages, there is still the need for further research in this field. (orig.)

  20. Cardiac Penetrating Injuries and Pseudoaneurysm

    Institute of Scientific and Technical Information of China (English)

    CHEN Shifeng

    2002-01-01

    Objective To discuss the early diagnosis and treatment of cardiac penetrating injuries and pseudoaneurysm. Methods 18 cases of cardiac penetrating injuries, in which 2 cases were complicated with pseudoaneurysm, were diagnosed by emergency operation and color Doppler echocardiography between May 1973 and Dec. 2001 in our hospital. The basis for emergency operation is the injured path locating in cardiac dangerous zone, severe shock or pericardial tamponade. ResultsAmong 18 cases of this study, 17 cases underwent emergency operation. During the operation, 11 cases were found injured in right ventricle, 2 cases were found injured in right atrium, 1 case was found injured in pulmonary artery,4 cases were found injured in left ventricle, 2 cases were found complicated with pseudoaneurysm. 17cases underwent cardiac repair including 1 case of rupture of aneurysm. 1 case underwent elective aneurysm resection. In whole group, 15 cases survived(83.33% ), 3 cases died( 16.67%). The cause of death is mainly hemorrhagic shock. Conclusion Highly suspicious cardiac penetrating injuries or hemopericaridium should undergo direct operative exploration. Pseudoaneurysm should be resected early,which can prevent severe complications.

  1. Peri-operative Levosimendan in Patients Undergoing Cardiac Surgery: An Overview of the Evidence.

    Science.gov (United States)

    Shi, William Y; Li, Sheila; Collins, Nicholas; Cottee, David B; Bastian, Bruce C; James, Allen N; Mejia, Ross

    2015-07-01

    Levosimendan, a calcium sensitiser, has recently emerged as a valuable agent in the peri-operative management of cardiac surgery patients. Levosimendan is a calcium-sensitising ionodilator. By binding to cardiac troponin C and reducing its calcium-binding co-efficient, it enhances myofilament responsiveness to calcium and thus enhances myocardial contractility without increasing oxygen demand. Current evidence suggests that levosimendan enhances cardiac function after cardiopulmonary bypass in patients with both normal and reduced left ventricular function. In addition to being used as post-operative rescue therapy for low cardiac output syndrome, a pre-operative levosimendan infusion in high risk patients with poor cardiac function may reduce inotropic requirements, the need for mechanical support, the duration of intensive care admissions as well as post-operative mortality. Indeed, it is these higher-risk patients who may experience a greater degree of benefit. Larger, multicentre randomised trials in cardiac surgery will help to elucidate the full potential of this agent.

  2. Toll-Like Receptor 9 Promotes Cardiac Inflammation and Heart Failure during Polymicrobial Sepsis

    Directory of Open Access Journals (Sweden)

    Ralph Lohner

    2013-01-01

    Full Text Available Background. Aim was to elucidate the role of toll-like receptor 9 (TLR9 in cardiac inflammation and septic heart failure in a murine model of polymicrobial sepsis. Methods. Sepsis was induced via colon ascendens stent peritonitis (CASP in C57BL/6 wild-type (WT and TLR9-deficient (TLR9-D mice. Bacterial load in the peritoneal cavity and cardiac expression of inflammatory mediators were determined at 6, 12, 18, 24, and 36 h. Eighteen hours after CASP cardiac function was monitored in vivo. Sarcomere length of isolated cardiomyocytes was measured at 0.5 to 10 Hz after incubation with heat-inactivated bacteria. Results. CASP led to continuous release of bacteria into the peritoneal cavity, an increase of cytokines, and differential regulation of receptors of innate immunity in the heart. Eighteen hours after CASP WT mice developed septic heart failure characterised by reduction of end-systolic pressure, stroke volume, cardiac output, and parameters of contractility. This coincided with reduced cardiomyocyte sarcomere shortening. TLR9 deficiency resulted in significant reduction of cardiac inflammation and a sustained heart function. This was consistent with reduced mortality in TLR9-D compared to WT mice. Conclusions. In polymicrobial sepsis TLR9 signalling is pivotal to cardiac inflammation and septic heart failure.

  3. Diabetes and cardiac autonomic neuropathy: Clinicalmanifestations, cardiovascular consequences, diagnosisand treatment

    Institute of Scientific and Technical Information of China (English)

    Akif Serhat Balcloglu; Haldun Müderrisoglu

    2015-01-01

    Cardiac autonomic neuropathy (CAN) is a frequentchronic complication of diabetes mellitus with potentiallylife-threatening outcomes. CAN is caused by theimpairment of the autonomic nerve fibers regulatingheart rate, cardiac output, myocardial contractility, cardiacelectrophysiology and blood vessel constriction anddilatation. It causes a wide range of cardiac disorders,including resting tachycardia, arrhythmias, intraoperativecardiovascular instability, asymptomatic myocardialischemia and infarction and increased rate of mortalityafter myocardial infarction. Etiological factors associatedwith autonomic neuropathy include insufficient glycemiccontrol, a longer period since the onset of diabetes,increased age, female sex and greater body mass index.The most commonly used methods for the diagnosisof CAN are based upon the assessment of heart ratevariability (the physiological variation in the time intervalbetween heartbeats), as it is one of the first findings inboth clinically asymptomatic and symptomatic patients.Clinical symptoms associated with CAN generally occurlate in the disease process and include early fatigue andexhaustion during exercise, orthostatic hypotension,dizziness, presyncope and syncope. Treatment is basedon early diagnosis, life style changes, optimization ofglycemic control and management of cardiovascular riskfactors. Medical therapies, including aldose reductaseinhibitors, angiotensin-converting enzyme inhibitors,prostoglandin analogs and alpha-lipoic acid, have beenfound to be effective in randomized controlled trials.The following article includes the epidemiology, clinicalfindings and cardiovascular consequences, diagnosis,and approaches to prevention and treatment of CAN.

  4. [Metabolic support of the ischemic heart during cardiac surgery].

    Science.gov (United States)

    Luna Ortiz, Pastor; Serrano Valdés, Xenia; Rojas Pérez, Eduardo; de Micheli, Alfredo

    2006-01-01

    We examine [IBM1] the basic principles and clinical results of the metabolic intervention with glucose-insulin-potassium (GIK) solutions in the field of cardiovascular surgery. On the basis of many international publications concerning this subject, and the experience obtained in the operating room of the Instituto Nacional de Cardiologia "Ignacio Chávez", we conclude that the metabolic support wit GIK is a powerful system that provides very useful energy to protect the myocardium during cardiac and non-cardiac surgery. The most recent publications indicate their effects in reducing low output syndromes, due to interventions on the coronary arteries, as well as producing a significant reduction of circulating fatty acids. These effects are produced also in the field of interventional cardiology, where GIK solutions protect the myocardium against damage due to impaired microcirculation. It is evident that these solutions must be utilized in higher concentrations that the initial ones, equal to those employed in laboratory animals. On the other side, it is worthy to remember that it has been always underlined that this treatment represents only a protection for the myocardium. Therefore, its association with other drugs or treatments favoring a good myocardial performance is not contraindicated--on the contrary, it yields better results. The present review presents pharmacological approaches, such as the use of glutamato, aspartate, piruvato, trimetazidina ranolazine and taurine to optimize cardiac energy metabolism, for the management of ischemic heart disease.

  5. Simulation evaluation of quantitative myocardial perfusion assessment from cardiac CT

    Science.gov (United States)

    Bindschadler, Michael; Modgil, Dimple; Branch, Kelley R.; La Riviere, Patrick J.; Alessio, Adam M.

    2014-03-01

    Contrast enhancement on cardiac CT provides valuable information about myocardial perfusion and methods have been proposed to assess perfusion with static and dynamic acquisitions. There is a lack of knowledge and consensus on the appropriate approach to ensure 1) sufficient diagnostic accuracy for clinical decisions and 2) low radiation doses for patient safety. This work developed a thorough dynamic CT simulation and several accepted blood flow estimation techniques to evaluate the performance of perfusion assessment across a range of acquisition and estimation scenarios. Cardiac CT acquisitions were simulated for a range of flow states (Flow = 0.5, 1, 2, 3 ml/g/min, cardiac output = 3,5,8 L/min). CT acquisitions were simulated with a validated CT simulator incorporating polyenergetic data acquisition and realistic x-ray flux levels for dynamic acquisitions with a range of scenarios including 1, 2, 3 sec sampling for 30 sec with 25, 70, 140 mAs. Images were generated using conventional image reconstruction with additional image-based beam hardening correction to account for iodine content. Time attenuation curves were extracted for multiple regions around the myocardium and used to estimate flow. In total, 2,700 independent realizations of dynamic sequences were generated and multiple MBF estimation methods were applied to each of these. Evaluation of quantitative kinetic modeling yielded blood flow estimates with an root mean square error (RMSE) of ~0.6 ml/g/min averaged across multiple scenarios. Semi-quantitative modeling and qualitative static imaging resulted in significantly more error (RMSE = ~1.2 and ~1.2 ml/min/g respectively). For quantitative methods, dose reduction through reduced temporal sampling or reduced tube current had comparable impact on the MBF estimate fidelity. On average, half dose acquisitions increased the RMSE of estimates by only 18% suggesting that substantial dose reductions can be employed in the context of quantitative myocardial

  6. Exercise-induced cardiac remodeling.

    Science.gov (United States)

    Weiner, Rory B; Baggish, Aaron L

    2012-01-01

    Early investigations in the late 1890s and early 1900s documented cardiac enlargement in athletes with above-normal exercise capacity and no evidence of cardiovascular disease. Such findings have been reported for more than a century and continue to intrigue scientists and clinicians. It is well recognized that repetitive participation in vigorous physical exercise results in significant changes in myocardial structure and function. This process, termed exercise-induced cardiac remodeling (EICR), is characterized by structural cardiac changes including left ventricular hypertrophy with sport-specific geometry (eccentric vs concentric). Associated alterations in both systolic and diastolic functions are emerging as recognized components of EICR. The increasing popularity of recreational exercise and competitive athletics has led to a growing number of individuals exhibiting these findings in routine clinical practice. This review will provide an overview of EICR in athletes.

  7. [Ectopia cordis and cardiac anomalies].

    Science.gov (United States)

    Cabrera, Alberto; Rodrigo, David; Luis, María Teresa; Pastor, Esteban; Galdeano, José Miguel; Esteban, Susana

    2002-11-01

    Ectopia cordis is a rare disease that occurs in 5.5 to 7.9 per million live births. Only 267 cases had been reported as of 2001, most (95%) associated with other cardiac anomalies. We studied the cardiac malformations associated in 6 patients with ectopia cordis. Depending on where the defect was located, the cases of ectopia were classified into four groups: cervical, thoracic, thoraco-abdominal, and abdominal. All 6 patients died before the third day of life, 4 during delivery. Three of the patients were included in the thoracic group, whereas the other 3 belonged to the thoraco-abdominal group. All the patients had associated ventricular septal defects, 3 double-outlet right ventricle (50%) and the rest (50%) tetralogy of Fallot-pulmonary atresia. Two patients with double-outlet right ventricle presented mitral-valve pathology, a parachute valve and an atresic mitral valve. None of these cardiac anomalies have been reported to date.

  8. Electrophysiological Cardiac Modeling: A Review.

    Science.gov (United States)

    Beheshti, Mohammadali; Umapathy, Karthikeyan; Krishnan, Sridhar

    2016-01-01

    Cardiac electrophysiological modeling in conjunction with experimental and clinical findings has contributed to better understanding of electrophysiological phenomena in various species. As our knowledge on underlying electrical, mechanical, and chemical processes has improved over time, mathematical models of the cardiac electrophysiology have become more realistic and detailed. These models have provided a testbed for various hypotheses and conditions that may not be easy to implement experimentally. In addition to the limitations in experimentally validating various scenarios implemented by the models, one of the major obstacles for these models is computational complexity. However, the ever-increasing computational power of supercomputers facilitates the clinical application of cardiac electrophysiological models. The potential clinical applications include testing and predicting effects of pharmaceutical agents and performing patient-specific ablation and defibrillation. A review of studies involving these models and their major findings are provided.

  9. 81. Upper body arterio-central venous PCO2 gap (UBCO2G in monitoring sick children with cardiac disease

    Directory of Open Access Journals (Sweden)

    Omar Mohammad Hijazi

    2015-10-01

    Conclusion: Upper is higher than lower body PCO2gap. UBPCO2G ⩾9.65 was associated with higher LA, BUN, creatinine, serum glucose and PRISM and lower urine output. Patients with UBPCO2G ⩾9.65 were sicker. UBPCO2G can be used as a biomarker in monitoring children with cardiac disease.

  10. Exceptional CO₂ tolerance in white sturgeon (Acipenser transmontanus) is associated with protection of maximum cardiac performance during hypercapnia in situ.

    Science.gov (United States)

    Baker, Daniel W; Hanson, Linda M; Farrell, Anthony P; Brauner, Colin J

    2011-01-01

    White sturgeon rank among the most CO₂-tolerant fish species examined to date. We investigated whether this exceptional CO₂ tolerance extended to the heart, an organ generally viewed as acidosis intolerant. Maximum cardiac output (Q(max)) and maximum cardiac power output (PO(max)) were assessed using a working, perfused, in situ heart preparation. Exposure to a Pco₂ of 3 kPa for 20 min had no significant effect on maximum cardiac performance, while exposure to 6-kPa Pco₂ reduced heart rate, Q(max), PO(max), and rate of ventricular force generation (F(O)) by 23%, 28%, 26%, and 18%, respectively; however, full recovery was observed in all these parameters upon return to control conditions. These modest impairments during exposure to 6-kPa Pco₂ were associated with partially compensated intracellular ventricular acidosis. Maximum adrenergic stimulation (500 nmol L⁻¹ adrenaline) during 6-kPa Pco₂ protected maximum cardiac performance via increased inotropy (force of contraction) without affecting heart rate. Exposure to higher CO₂ levels associated with morbidity in vivo (i.e., 8-kPa Pco₂) induced arrhythmia and a reduction in stroke volume during power assessment. Clearly, white sturgeon hearts are able to increase cardiac performance during severe hypercapnia that is lethal to other fishes. Future work focusing on atypical aspects of sturgeon cardiac function, including the lack of chronotropic response to adrenergic stimulation during hypercapnia, is warranted.

  11. The Importance of Output in SLA and Its Pedagogical Implications

    Institute of Scientific and Technical Information of China (English)

    何婧媛

    2014-01-01

    Input and output in second language acquisition are closely related. Input is the essential preparation for output, while output is the purpose of input, and in turn promotes input. They complement each other and help to improve students ’linguis⁃tic competence. Comprehensible input and output are equally important in language learning. Therefore, it is unwise to ignore the roles of output in pedagogical situation.

  12. An update on insertable cardiac monitors

    DEFF Research Database (Denmark)

    Olsen, Flemming J; Biering-Sørensen, Tor; Krieger, Derk W

    2015-01-01

    Continuous cardiac rhythm monitoring has undergone compelling progress over the past decades. Cardiac monitoring has emerged from 12-lead electrocardiograms being performed at the discretion of the treating physician to in-hospital telemetry, Holter monitoring, prolonged external event monitoring...

  13. Complications after cardiac implantable electronic device implantations

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard;

    2014-01-01

    Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient...

  14. Clinical advances on Cardiac Insuffiency

    Directory of Open Access Journals (Sweden)

    Angel Julio Romero Cabrera

    2007-06-01

    Full Text Available Cardiac insuffiency is a complex clinical syndrome which constitutes a common final path to get in by the majority of the cardiac diseases. Studies based on the communitarian surveys shows that from 30 to 40 % of the patients decease within the first year of the diagnosis. The rest of the patients (from 60 to 70 % die within the 5 years after being diagnosed. For this reason it has been called as the ¨cancer of cardiology¨. The objective of this article is to update the advances reached in the clinical and therapeutic aspects of this important syndrome.

  15. Elevated sensitivity to cardiac ischemia in proteinuric rats is independent of adverse cardiac remodeling

    NARCIS (Netherlands)

    Szymanski, Mariusz K.; Hillege, Hans L.; Danser, A. H. Jan; Garrelds, Ingrid M.; Schoemaker, Regien G.

    2013-01-01

    Objectives: Chronic renal dysfunction severely increases cardiovascular risk. Adverse cardiac remodeling is suggested to play a major role as predisposition for increased cardiac ischemic vulnerability. The aim of the present study was to examine the role of adverse cardiac remodeling in cardiac sen

  16. Pregnancy as a cardiac stress model

    OpenAIRE

    2014-01-01

    Cardiac hypertrophy occurs during pregnancy as a consequence of both volume overload and hormonal changes. Both pregnancy- and exercise-induced cardiac hypertrophy are generally thought to be similar and physiological. Despite the fact that there are shared transcriptional responses in both forms of cardiac adaptation, pregnancy results in a distinct signature of gene expression in the heart. In some cases, however, pregnancy can induce adverse cardiac events in previously healthy women witho...

  17. Bifid cardiac apex in a 25-year-old male with sudden cardiac death.

    Science.gov (United States)

    Wu, Annie; Kay, Deborah; Fishbein, Michael C

    2014-01-01

    Although a bifid cardiac apex is common in certain marine animals, it is an uncommon finding in humans. When present, bifid cardiac apex is usually associated with other congenital heart anomalies. We present a case of bifid cardiac apex that was an incidental finding in a 25-year-old male with sudden cardiac death from combined drug toxicity. On gross examination, there was a bifid cardiac apex with a 2-cm long cleft. There were no other significant gross or microscopic abnormalities. This case represents the very rare occurrence of a bifid cardiac apex as an isolated cardiac anomaly.

  18. Uncertainties in predicting solar panel power output

    Science.gov (United States)

    Anspaugh, B.

    1974-01-01

    The problem of calculating solar panel power output at launch and during a space mission is considered. The major sources of uncertainty and error in predicting the post launch electrical performance of the panel are considered. A general discussion of error analysis is given. Examples of uncertainty calculations are included. A general method of calculating the effect on the panel of various degrading environments is presented, with references supplied for specific methods. A technique for sizing a solar panel for a required mission power profile is developed.

  19. Inductive Output Tubes -- Status and Future Direction

    Science.gov (United States)

    Bohlen, Heinz

    2002-08-01

    Invented in 1938, at the same time as the klystron, it took the Inductive Output Tube (IOT) more than 40 years to surface as a useful device. Its progress after that event was rapid. Though plagued by teething problems in the beginning, it has since replaced the klystron as a TV amplifier in UHF, and it holds its own against the solid-state competition in that application. The IOT also shows much promise as a high-power amplifier, but early developments in this direction have remained solitary events so far. The paper discusses the causes and the potential of the device for future high-power applications.

  20. REGULARIZATION OF SINGULAR SYSTEMS BY OUTPUT FEEDBACK

    Institute of Scientific and Technical Information of China (English)

    De-lin Chu; Da-yong Cai

    2000-01-01

    Problem of regularization of a singular system by derivative and proportional output feedback is studied. Necessary and sufficient conditions are obtained under which a singular system can be regularized into a closed-loop system that is regular and of index at most one. The reduced form is given that can easily explore the system properties as well as the feedback to be determined. The main results of the present paper are based on orthogonal transformations. Therefore, they can be implemented by numerically stable ways.

  1. Input-output-controlled nonlinear equation solvers

    Science.gov (United States)

    Padovan, Joseph

    1988-01-01

    To upgrade the efficiency and stability of the successive substitution (SS) and Newton-Raphson (NR) schemes, the concept of input-output-controlled solvers (IOCS) is introduced. By employing the formal properties of the constrained version of the SS and NR schemes, the IOCS algorithm can handle indefiniteness of the system Jacobian, can maintain iterate monotonicity, and provide for separate control of load incrementation and iterate excursions, as well as having other features. To illustrate the algorithmic properties, the results for several benchmark examples are presented. These define the associated numerical efficiency and stability of the IOCS.

  2. Example of input-output analysis

    Science.gov (United States)

    1975-01-01

    The thirty sectors included in the ECASTAR energy input-output model were listed. Five of these belong to energy producing sectors, fifteen to manufacturing industries, two to residential and commercial sectors, and eight to service industries. The model is capable of tracing impacts of an action in three dimensions: dollars, BTU's of energy, and labor. Four conservation actions considered were listed and then discussed separately, dealing with the following areas: increase in fuel efficiency, reduction in fuel used by the transportation and warehousing group, manufacturing of smaller automobiles, and a communications/transportation trade-off.

  3. Thymic Output: Influence Factors and Molecular Mechanism

    Institute of Scientific and Technical Information of China (English)

    Rong Jin; Jun Zhang; Weifeng Chen

    2006-01-01

    Thymus is a primary lymphoid organ, able to generate mature T cells that eventually colonize secondary lymphoid organs, and is therefore essential for peripheral T cell renewal. Recent data showed that normal thymocyte export can be altered by several influence factors including several chemokines,sphingosinel-phosphate (S1P),transcription factors such as Foxjl, Kruppel-like transcription factor 2 (KLF2) and antigen stimulation, etc. In this review, we summarized the recent reports about study strategies, influence factors and possible molecular mechanisms in thymic output.

  4. Modelling Waste Output from Trout Farms

    DEFF Research Database (Denmark)

    Frier, J. O.; From, J.; Larsen, Torben

    1995-01-01

    to calculate waste discharge from existing and planned aquaculture activities. A special purpose is simulating outcome of waste water treatment and altered feeding programmes. Different submodels must be applied for P, N, and organics, as well as for the different phases of food and waste treatment. Altogether......The aim of waste modelling in aquaculture is to provide tools for simulating input, transformation, output and subsidiary degradation in recipients of organic compounds, nitrogen, and phosphorus. The direct purpose of this modelling is to make it possible for caretakers and water authorities...

  5. Discovery and progress of direct cardiac reprogramming.

    Science.gov (United States)

    Kojima, Hidenori; Ieda, Masaki

    2017-02-14

    Cardiac disease remains a major cause of death worldwide. Direct cardiac reprogramming has emerged as a promising approach for cardiac regenerative therapy. After the discovery of MyoD, a master regulator for skeletal muscle, other single cardiac reprogramming factors (master regulators) have been sought. Discovery of cardiac reprogramming factors was inspired by the finding that multiple, but not single, transcription factors were needed to generate induced pluripotent stem cells (iPSCs) from fibroblasts. We first reported a combination of cardiac-specific transcription factors, Gata4, Mef2c, and Tbx5 (GMT), that could convert mouse fibroblasts into cardiomyocyte-like cells, which were designated as induced cardiomyocyte-like cells (iCMs). Following our first report of cardiac reprogramming, many researchers, including ourselves, demonstrated an improvement in cardiac reprogramming efficiency, in vivo direct cardiac reprogramming for heart regeneration, and cardiac reprogramming in human cells. However, cardiac reprogramming in human cells and adult fibroblasts remains inefficient, and further efforts are needed. We believe that future research elucidating epigenetic barriers and molecular mechanisms of direct cardiac reprogramming will improve the reprogramming efficiency, and that this new technology has great potential for clinical applications.

  6. Multimodality imaging to guide cardiac interventional procedures

    NARCIS (Netherlands)

    Tops, Laurens Franciscus

    2010-01-01

    In recent years, a number of new cardiac interventional procedures have been introduced. Catheter ablation procedures for atrial fibrillation (AF) have been refined and are now considered a good treatment option in patients with drug-refractory AF. In cardiac pacing, cardiac resynchronization therap

  7. Cardiac manifestations of myotonic dystrophy type 1

    DEFF Research Database (Denmark)

    Petri, Helle; Vissing, John; Witting, Nanna;

    2012-01-01

    To estimate the degree of cardiac involvement regarding left ventricular ejection fraction, conduction abnormalities, arrhythmia, risk of sudden cardiac death (SCD) and the associations between cardiac involvement and cytosine-thymine-guanine (CTG)-repeat, neuromuscular involvement, age and gende...... in patients with myotonic dystrophy type 1 (MD1)....

  8. Cardiac anatomy and physiology: a review.

    Science.gov (United States)

    Gavaghan, M

    1998-04-01

    This article reviews the normal anatomy and physiology of the heart. Understanding the normal anatomic and physiologic relationships described in this article will help perioperative nurses care for patients who are undergoing cardiac procedures. Such knowledge also assists nurses in educating patients about cardiac procedures and about activities that can prevent, reverse, or improve cardiac illness.

  9. Bifurcations in a nonlinear model of the baroreceptor-cardiac reflex

    Science.gov (United States)

    Seidel, H.; Herzel, H.

    1998-04-01

    We investigate the dynamic properties of a nonlinear model of the human cardio-baroreceptor control loop. As a new feature we use a phase effectiveness curve to describe the experimentally well-known phase dependency of the cardiac pacemaker's sensitivity to neural activity. We show that an increase of sympathetic time delays leads via a Hopf bifurcation to sustained heart rate oscillations. For increasing baroreflex sensitivity or for repetitive vagal stimulation we observe period-doubling, toroidal oscillations, chaos, and entrainment between the rhythms of the heart and the control loop. The bifurcations depend crucially on the involvement of the cardiac pacemaker's phase dependency. We compare the model output with experimental data from electrically stimulated anesthetized dogs and discuss possible implications for cardiac arrhythmias.

  10. Moore′s law, Dabbawalas, and pediatric cardiac care in Sri Lanka

    Directory of Open Access Journals (Sweden)

    Duminda Samarasinghe

    2015-01-01

    Full Text Available Sri Lanka is an island nation in Indian Ocean that provides free healthcare to all citizens through government healthcare system. It has commendable health indices in the region. Pediatric cardiac services have rapidly progressed over past few years helping to further bring down infant and under-five mortality rates. Lady Ridgeway Hospital for Children (LRH is the only tertiary care referral center for children with heart disease in the country. Currently it performs approximately 1,000 cardiac catheterizations and 1,000 cardiac surgeries every year. Target is to double the surgical output to treat all children with heart diseases in a timely and appropriate manner. Being a middle-income country, this is not an easy task. Technology used in diagnosis and treatment of congenital heart diseases is rapidly advancing with its price tag. In such a setting, it is challenging to proceed to achieve this target in a resource-limited environment.

  11. Cardiac abnormalities in acromegaly. Pathophysiology and implications for management.

    Science.gov (United States)

    Vitale, Giovanni; Pivonello, Rosario; Lombardi, Gaetano; Colao, Annamaria

    2004-01-01

    Cardiovascular disease is claimed to be one of the most severe complications of acromegaly, contributing significantly to mortality in this disease. In fact, an excess of growth hormone (GH) and insulin-like growth factor 1 (IGF-I) causes a specific derangement of cardiomyocytes, leading to abnormalities in cardiac muscle structure and function, inducing a specific cardiomyopathy. In the early phase of acromegaly the excess of GH and IGF-I induces a hyperkinetic syndrome, characterized by increased heart rate and increased systolic output. Concentric hypertrophy is the most common feature of cardiac involvement in acromegaly, found in more than two thirds of patients at diagnosis. This abnormality is commonly associated with diastolic dysfunction and eventually with impaired systolic function ending in heart failure, if the GH/IGF-I excess is left untreated. In addition, abnormalities of cardiac rhythm and of heart valves have also been described in acromegaly. The coexistence of other complications, such as arterial hypertension and diabetes mellitus, aggravates acromegalic cardiomyopathy. Successful control of acromegaly induces a decrease in left ventricular mass and an improvement in diastolic function, while the effects of GH/IGF-I suppression on systolic function are more variable. However, since cardiovascular alterations in young patients with short disease duration are milder than in those with longer disease duration, it is likely to be easier to reverse and/or arrest acromegalic cardiomyopathy in young patients with early-onset disease. In conclusion, careful assessments of cardiac function, morphology, and activity are required in patients with acromegaly. An early diagnosis and prompt effective treatment are important in order to reverse acromegalic cardiomyopathy.

  12. Cardiac tumors: optimal cardiac MR sequences and spectrum of imaging appearances.

    LENUS (Irish Health Repository)

    O'Donnell, David H

    2012-02-01

    OBJECTIVE: This article reviews the optimal cardiac MRI sequences for and the spectrum of imaging appearances of cardiac tumors. CONCLUSION: Recent technologic advances in cardiac MRI have resulted in the rapid acquisition of images of the heart with high spatial and temporal resolution and excellent myocardial tissue characterization. Cardiac MRI provides optimal assessment of the location, functional characteristics, and soft-tissue features of cardiac tumors, allowing accurate differentiation of benign and malignant lesions.

  13. Molecular therapies for cardiac arrhythmias

    NARCIS (Netherlands)

    Boink, G.J.J.

    2013-01-01

    Despite the ongoing advances in pharmacology, devices and surgical approaches to treat heart rhythm disturbances, arrhythmias are still a significant cause of death and morbidity. With the introduction of gene and cell therapy, new avenues have arrived for the local modulation of cardiac disease. Th

  14. The cardiac patient in Ramadan.

    Science.gov (United States)

    Chamsi-Pasha, Majed; Chamsi-Pasha, Hassan

    2016-01-01

    Ramadan is one of the five fundamental pillars of Islam. During this month, the majority of the 1.6 billion Muslims worldwide observe an absolute fast from dawn to sunset without any drink or food. Our review shows that the impact of fasting during Ramadan on patients with stable cardiac disease is minimal and does not lead to any increase in acute events. Most patients with the stable cardiac disease can fast safely. Most of the drug doses and their regimen are easily manageable during this month and may need not to be changed. Ramadan fasting is a healthy nonpharmacological means for improving cardiovascular risk factors. Most of the Muslims, who suffer from chronic diseases, insist on fasting Ramadan despite being exempted by religion. The Holy Quran specifically exempts the sick from fasting. This is particularly relevant if fasting worsens one's illness or delays recovery. Patients with unstable angina, recent myocardial infarction, uncontrolled hypertension, decompensated heart failure, recent cardiac intervention or cardiac surgery or any debilitating diseases should avoid fasting.

  15. Pseudothrombocytopenia in cardiac surgical practice.

    Science.gov (United States)

    Nair, Sukumaran K; Shah, Roma; Petko, Matus; Keogh, Bruce E

    2007-08-01

    Pseudothrombocytopenia is observed occasionally in post-cardiac surgical patients. It is commonly due to EDTA-mediated immunological mechanisms, which lead to agglutination of functionally intact platelets. This condition is harmless and does not warrant platelet transfusion. We describe an instance of pseudothrombocytopenia in our practice and discuss its clinical relevance.

  16. Thoracocentesis in cardiac surgery patients.

    Science.gov (United States)

    Wickbom, Anders; Cha, Soon Ok; Ahlsson, Anders

    2015-01-01

    Pleural effusion following cardiac surgery is a common complication that sometimes requires invasive treatment. Conventional methods for evacuation include needle aspiration and chest tube insertion. We present an effective, easy and potentially time-saving method of thoracocentesis, using a single-lumen central venous catheter.

  17. Reninoma presenting as cardiac syncope

    Directory of Open Access Journals (Sweden)

    Tak Shahid

    2011-01-01

    Full Text Available Reninoma, a renin-secreting tumor of the juxta-glomerular cells of the kidney, is a rare but surgically treatable cause of secondary hypertension in children. We report a case of reninoma presenting as cardiac syncope with long QTc on electrocardiogram due to hypokalemia.

  18. Cardiac leiomyosarcoma, a case report

    DEFF Research Database (Denmark)

    Andersen, Rikke; Kristensen, Bjarne W; Gill, Sabine

    2013-01-01

    In this case report we present the history of a patient admitted with recurrent pulmonary edema. Transesophageal chocardiography showed a tumour in the left atrium, occluding the ostium of the mitral valve and mimicking intermittent mitral stenosis. Cardiac surgery followed by pathological...

  19. Cardiac connexins and impulse propagation

    NARCIS (Netherlands)

    J.A. Jansen; T.A.B. van Veen; J.M.T. de Bakker; H.V.M. van Rijen

    2010-01-01

    Gap junctions form the intercellular pathway for cell-to-cell transmission of the cardiac impulse from its site of origin, the sinoatrial node, along the atria, the atrioventricular conduction system to the ventricular myocardium. The component parts of gap junctions are proteins called connexins (C

  20. [Acute cardiac failure in pheochromocytoma.

    DEFF Research Database (Denmark)

    Jønler, Morten; Munk, Kim

    2008-01-01

    Pheochromocytoma (P) is an endocrine catecholamine-secreting tumor. Classical symptoms like hypertension, attacks of sweating, palpitations, headache and palor are related to catecholamine discharge. We provide a case of P in a 71 year-old man presenting with acute cardiac failure, severe reduction...

  1. Cardiac resynchronization therapy in China

    Institute of Scientific and Technical Information of China (English)

    Wei HUA

    2006-01-01

    @@ Congestive heart failure (HF) is a major and growing public health problem. The therapeutic approach includes non-pharmacological measures, pharmacological therapy,mechanical devices, and surgery. Despite the benefits of optimal pharmacologic therapy, the prognosis is still not ideal. At this time, cardiac resynchronization therapy (CRT)has gained wide acceptance as an alternative treatment for HF patients with conduction delay.1

  2. Cardiac abnormalities after subarachnoid hemorrhage

    NARCIS (Netherlands)

    Bilt, I.A.C. van der

    2016-01-01

    Aneurysmal subarachnoid hemorrhage(aSAH) is a devastating neurological disease. During the course of the aSAH several neurological and medical complications may occur. Cardiac abnormalities after aSAH are observed often and resemble stress cardiomyopathy or Tako-tsubo cardiomyopathy(Broken Heart Syn

  3. Response to cardiac resynchronization therapy

    DEFF Research Database (Denmark)

    Versteeg, Henneke; Schiffer, Angélique A; Widdershoven, Jos W

    2009-01-01

    Cardiac resynchronization therapy (CRT) is a promising treatment for a subgroup of patients with advanced congestive heart failure and a prolonged QRS interval. Despite the majority of patients benefiting from CRT, 10-40% of patients do not respond to this treatment and are labeled as nonresponders...

  4. Energy Harvesting by Subcutaneous Solar Cells: A Long-Term Study on Achievable Energy Output.

    Science.gov (United States)

    Bereuter, L; Williner, S; Pianezzi, F; Bissig, B; Buecheler, S; Burger, J; Vogel, R; Zurbuchen, A; Haeberlin, A

    2017-01-03

    Active electronic implants are powered by primary batteries, which induces the necessity of implant replacement after battery depletion. This causes repeated interventions in a patients' life, which bears the risk of complications and is costly. By using energy harvesting devices to power the implant, device replacements may be avoided and the device size may be reduced dramatically. Recently, several groups presented prototypes of implants powered by subcutaneous solar cells. However, data about the expected real-life power output of subcutaneously implanted solar cells was lacking so far. In this study, we report the first real-life validation data of energy harvesting by subcutaneous solar cells. Portable light measurement devices that feature solar cells (cell area = 3.6 cm(2)) and continuously measure a subcutaneous solar cell's output power were built. The measurement devices were worn by volunteers in their daily routine in summer, autumn and winter. In addition to the measured output power, influences such as season, weather and human activity were analyzed. The obtained mean power over the whole study period was 67 µW (=19 µW cm(-2)), which is sufficient to power e.g. a cardiac pacemaker.

  5. Molecular Modeling of Cardiac Troponin

    Science.gov (United States)

    Manning, Edward P.

    The cardiac thin filament regulates interactions of actin and myosin, the force-generating elements of muscular contraction. Over the past several decades many details have been discovered regarding the structure and function of the cardiac thin filament and its components, including cardiac troponin (cTn). My hypothesis is that signal propagation occurs between distant ends of the cardiac troponin complex through calcium-dependent alterations in the dynamics of cTn and tropomyosin (Tm). I propose a model of the thin filament that encompasses known structures of cTn, Tm and actin to gain insight into cardiac troponin's allosteric regulation of thin filament dynamics. By performing molecular dynamics simulations of cTn in conjunction with overlapping Tm in two conditions, with and without calcium bound to site II of cardiac troponin C (cTnC), I found a combination of calcium-dependent changes in secondary structure and dynamics throughout the cTn-Tm complex. I then applied this model to investigate familial hypertrophic cardiomyopathy (FHC), a disease of the sarcomere that is one of the most commonly occurring genetic causes of heart disease. Approximately 15% of known FHC-related mutations are found in cardiac troponin T (cTnT), most of which are in or flank the alpha-helical N-tail domain TNT1. TNT1 directly interacts with overlapping Tm coiled coils. Using this model I identified effects of TNT1 mutations that propagate to the cTn core where site II of cTnC, the regulatory site of calcium binding in the thin filament, is located. Specifically, I found that mutations in TNT1 alter the flexibility of TNT1 and that the flexibility of TNT1 is inversely proportional to the cooperativity of calcium activation of the thin filament. Further, I identified a pathway of propagation of structural and dynamic changes linking TNT1 to site II of cTnC. Mutation-induced changes at site II cTnC alter calcium coordination which corresponds to biophysical measurements of calcium

  6. [Interferences and cardiac pacemakers--defibrillators. Results of in vivo experiments and radio frequencies].

    Science.gov (United States)

    Trigano, J A

    2003-04-01

    Interference with cardiac pacemakers and defibrillators by cellular phone and electronic article surveillance systems is shown in experimental studies with disparate findings. Interaction occurrence in real life is a convincing but rare experience. Device model, distance, power output and technology of the source are different and sometimes uncontrollable factors. As a result it remains difficult to quantify the true incidence of interaction and associated health risk. Nevertheless, simple recommendations commonly help the patients to prevent the interference.

  7. A Monte Carlo Study on Multiple Output Stochastic Frontiers

    DEFF Research Database (Denmark)

    Henningsen, Géraldine; Henningsen, Arne; Jensen, Uwe

    In the estimation of multiple output technologies in a primal approach, the main question is how to handle the multiple outputs. Often an output distance function is used, where the classical approach is to exploit its homogeneity property by selecting one output quantity as the dependent variable...... of both specifications for the case of a Translog output distance function with respect to different common statistical problems as well as problems arising as a consequence of zero values in the output quantities. Although, our results partly show clear reactions to statistical misspecifications...

  8. Dense Output for Strong Stability Preserving Runge–Kutta Methods

    KAUST Repository

    Ketcheson, David I.

    2016-12-10

    We investigate dense output formulae (also known as continuous extensions) for strong stability preserving (SSP) Runge–Kutta methods. We require that the dense output formula also possess the SSP property, ideally under the same step-size restriction as the method itself. A general recipe for first-order SSP dense output formulae for SSP methods is given, and second-order dense output formulae for several optimal SSP methods are developed. It is shown that SSP dense output formulae of order three and higher do not exist, and that in any method possessing a second-order SSP dense output, the coefficient matrix A has a zero row.

  9. Can cardiac surgery cause hypopituitarism?

    Science.gov (United States)

    Francis, Flverly; Burger, Ines; Poll, Eva Maria; Reineke, Andrea; Strasburger, Christian J; Dohmen, Guido; Gilsbach, Joachim M; Kreitschmann-Andermahr, Ilonka

    2012-03-01

    Apoplexy of pituitary adenomas with subsequent hypopituitarism is a rare but well recognized complication following cardiac surgery. The nature of cardiac on-pump surgery provides a risk of damage to the pituitary because the vascular supply of the pituitary is not included in the cerebral autoregulation. Thus, pituitary tissue may exhibit an increased susceptibility to hypoperfusion, ischemia or intraoperative embolism. After on-pump procedures, patients often present with physical and psychosocial impairments which resemble symptoms of hypopituitarism. Therefore, we analyzed whether on-pump cardiac surgery may cause pituitary dysfunction also in the absence of pre-existing pituitary disease. Twenty-five patients were examined 3-12 months after on-pump cardiac surgery. Basal hormone levels for all four anterior pituitary hormone axes were measured and a short synacthen test and a growth hormone releasing hormone plus arginine (GHRH-ARG)-test were performed. Quality of life (QoL), depression, subjective distress for a specific life event, sleep quality and fatigue were assessed by means of self-rating questionnaires. Hormonal alterations were only slight and no signs of anterior hypopituitarism were found except for an insufficient growth hormone rise in two overweight patients in the GHRH-ARG-test. Psychosocial impairment was pronounced, including symptoms of moderate to severe depression in 9, reduced mental QoL in 8, dysfunctional coping in 6 and pronounced sleep disturbances in 16 patients. Hormone levels did not correlate with psychosocial impairment. On-pump cardiac surgery did not cause relevant hypopituitarism in our sample of patients and does not serve to explain the psychosocial symptoms of these patients.

  10. Cardiac energetics: sense and nonsense.

    Science.gov (United States)

    Gibbs, Colin L

    2003-08-01

    1. The background to current ideas in cardiac energetics is outlined and, in the genomic era, the need is stressed for detailed knowledge of mouse heart mechanics and energetics. 2. The mouse heart is clearly different to the rat in terms of its excitation-contraction (EC) coupling and the common assumption that heart rate difference between mice and humans will account for the eightfold difference in myocardial oxygen consumption is wrong, because the energy per beat of the mouse heart is approximately one-third that of the human heart. 3. In vivo evidence suggests that there may well be an eightfold species difference in the non-beating metabolism of mice and human hearts. It is speculated that the magnitude of basal metabolism in the heart is regulatable and that, in the absence of perfusion, it falls to approximately one-quarter of its in vivo rate and that in clinical conditions, such as hibernation, it probably decreases; its magnitude may be controlled by the endothelium. 4. The active energy balance sheet is briefly discussed and it is suggested that the activation heat accounts for 20-25% of the active energy per beat and cross-bridge turnover accounts for the balance. It is argued that force, not shortening, is the major determinant of cardiac energy usage. 5. The outcome of recent cardiac modelling with variants of the Huxley and Hill/Eisenberg models is described. It has been necessary to invoke 'loose coupling' to replicate the low cardiac energy flux measured at low afterloads (medium to high velocities of shortening). 6. Lastly, some of the unexplained or 'nonsense' energetic data are outlined and eight unsolved problems in cardiac energetics are discussed.

  11. Comparison of CAISO-run Plexos output with LLNL-run Plexos output

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, A; Meyers, C; Smith, S

    2011-12-20

    In this report we compare the output of the California Independent System Operator (CAISO) 33% RPS Plexos model when run on various computing systems. Specifically, we compare the output resulting from running the model on CAISO's computers (Windows) and LLNL's computers (both Windows and Linux). We conclude that the differences between the three results are negligible in the context of the entire system and likely attributed to minor differences in Plexos version numbers as well as the MIP solver used in each case.

  12. AN ALTERNATIVE APPROACH TO GLOBAL ROBUST OUTPUT REGULATION OF OUTPUT FEEDBACK SYSTEMS

    Institute of Scientific and Technical Information of China (English)

    Jie HUANG

    2007-01-01

    The global robust output regulation problem of the output feedback systems has been extensively studied under various assumptions of the complexity and uncertainty. All these approaches boil down to a stabilization problem of a so-called augmented extended system. This paper will describe an alternative approach which converts the original problem into a stabilization problem of a so-called extended augmented system. As the extended augmented system is somewhat simpler than the augmented extended system, this alternative approach is also simpler than the first approach.

  13. Interventional guidance for cardiac resynchronization therapies: merging anatomic X-ray imaging with functional ultrasound imaging based on mutually-shared landmarks

    Energy Technology Data Exchange (ETDEWEB)

    Manzke, R.; Shechter, G.; Gutierrez, L.; Chan, R.C. [Philips Research North America, Briarcliff Manor, NY (United States); Tournoux, F.; Singh, J.; Picard, M. [Dept. of Cardiology, Massachusetts General Hospital, Harvard Medical School (United States); Brink, B. v.d.; Boomen, R. v.d. [Philips Medical System, Best (Netherlands); Gerard, O. [Philips Medical Systems, Paris (France)

    2007-06-15

    Detailed knowledge of cardiac anatomy and function is required for complex cardiac electrophysiology interventions. Cardiac resynchronization therapies (CRT), for example, requires information about coronary venous anatomy for left ventricular lead placement. In CRT, heart failure patients are equipped with dual-chamber pacemakers in order to improve cardiac output and heart failure symptoms. Cardiac function is mainly assessed with Ultrasound imaging. Fusion of complementary information from X-ray and ultrasound is an essential step towards fully utilizing all available information for CRT guidance. We present an approach for fusion of anatomical information (coronary vein structure) from X-ray with functional information (left ventricular deformation and dynamics) from ultrasound. We propose an image-based fusion approach based on mutually-shared landmarks which enable registration of both imaging spaces without the need for external tracking. (orig.)

  14. Computer Diagnosis of Output Light Signals

    Directory of Open Access Journals (Sweden)

    Elisabeta Spunei

    2015-09-01

    Full Text Available Modern applications for PCs, mobile phones or tablets are increasingly stirring the interest of users and contribute to the labour productiveness in diverse fields. The paper presents the method of computer diagnostic of output signals in railway stations, based on the diagrams and diagnosis software, elaborated by the authors. The diagnostic diagrams were drawn up by using the diagrams from the stations with electrodynamics centralisation (CED of the CR4 type. The software may run on diverse modern devices and can be also adapted for other types of CED installations. Grace to the answers to different questions asked by the application, the possible causes of the failure or fault may be displayed fast and accurately. The purpose of the computer diagnostic is to reduce the normal diagnosis time.

  15. Linear quadratic output tracking and disturbance rejection

    Science.gov (United States)

    Karimi-Ghartemani, Masoud; Khajehoddin, S. Ali; Jain, Praveen; Bakhshai, Alireza

    2011-08-01

    This article introduces the problem of linear quadratic tracking (LQT) where the objective is to design a closed-loop control scheme such that the output signal of the system optimally tracks a given reference signal and rejects a given disturbance. Different performance indices that have been used to address the tracking problem are discussed and an appropriate new form is introduced. It is shown that a solution to the proposed optimality index exists under very mild conditions of stabilisability and detectability of the plant state-space equations. The solution is formulated based on converting the LQT problem to a standard linear quadratic regulation problem. The method is applied to two examples, a first-order plant and a third-order plant, and their simulation results are presented and discussed.

  16. Output-Sensitive Pattern Extraction in Sequences

    DEFF Research Database (Denmark)

    Grossi, Roberto; Menconi, Giulia; Pisanti, Nadia

    2014-01-01

    Genomic Analysis, Plagiarism Detection, Data Mining, Intrusion Detection, Spam Fighting and Time Series Analysis are just some examples of applications where extraction of recurring patterns in sequences of objects is one of the main computational challenges. Several notions of patterns exist...... n. We address the problem of extracting maximal patterns with at most k don’t care symbols and at least q occurrences. Our contribution is to give the first algorithm that attains a stronger notion of output-sensitivity, borrowed from the analysis of data structures: the cost is proportional...... to the actual number of occurrences of each pattern, which is at most n and practically much smaller than n in real applications, thus avoiding the aforementioned cost of O(nc) per pattern....

  17. Visualizing output for a data learning algorithm

    Science.gov (United States)

    Carson, Daniel; Graham, James; Ternovskiy, Igor

    2016-05-01

    This paper details the process we went through to visualize the output for our data learning algorithm. We have been developing a hierarchical self-structuring learning algorithm based around the general principles of the LaRue model. One example of a proposed application of this algorithm would be traffic analysis, chosen because it is conceptually easy to follow and there is a significant amount of already existing data and related research material with which to work with. While we choose the tracking of vehicles for our initial approach, it is by no means the only target of our algorithm. Flexibility is the end goal, however, we still need somewhere to start. To that end, this paper details our creation of the visualization GUI for our algorithm, the features we included and the initial results we obtained from our algorithm running a few of the traffic based scenarios we designed.

  18. Cardiac lipid content is unresponsive to a physical activity training intervention in type 2 diabetic patients, despite improved ejection fraction

    Directory of Open Access Journals (Sweden)

    Leiner Tim

    2011-05-01

    Full Text Available Abstract Background Increased cardiac lipid content has been associated with diabetic cardiomyopathy. We recently showed that cardiac lipid content is reduced after 12 weeks of physical activity training in healthy overweight subjects. The beneficial effect of exercise training on cardiovascular risk is well established and the decrease in cardiac lipid content with exercise training in healthy overweight subjects was accompanied by improved ejection fraction. It is yet unclear whether diabetic patients respond similarly to physical activity training and whether a lowered lipid content in the heart is necessary for improvements in cardiac function. Here, we investigated whether exercise training is able to lower cardiac lipid content and improve cardiac function in type 2 diabetic patients. Methods Eleven overweight-to-obese male patients with type 2 diabetes mellitus (age: 58.4 ± 0.9 years, BMI: 29.9 ± 0.01 kg/m2 followed a 12-week training program (combination endurance/strength training, three sessions/week. Before and after training, maximal whole body oxygen uptake (VO2max and insulin sensitivity (by hyperinsulinemic, euglycemic clamp was determined. Systolic function was determined under resting conditions by CINE-MRI and cardiac lipid content in the septum of the heart by Proton Magnetic Resonance Spectroscopy. Results VO2max increased (from 27.1 ± 1.5 to 30.1 ± 1.6 ml/min/kg, p = 0.001 and insulin sensitivity improved upon training (insulin stimulated glucose disposal (delta Rd of glucose improved from 5.8 ± 1.9 to 10.3 ± 2.0 μmol/kg/min, p = 0.02. Left-ventricular ejection fraction improved after training (from 50.5 ± 2.0 to 55.6 ± 1.5%, p = 0.01 as well as cardiac index and cardiac output. Unexpectedly, cardiac lipid content in the septum remained unchanged (from 0.80 ± 0.22% to 0.95 ± 0.21%, p = 0.15. Conclusions Twelve weeks of progressive endurance/strength training was effective in improving VO2max, insulin sensitivity

  19. Cardiac troponin: an emerging cardiac biomarker in animal health

    Directory of Open Access Journals (Sweden)

    Vishal V. Undhad

    Full Text Available Analysis of cardiac troponin I (cTn I and T (cTnT are considered the “gold standard” for the non-invasive diagnosis of myocardial injury in human and animals. It has replaced traditionally used cardiac biomarkers such as myoglobin, lactate dehydrogenase (LDH, creatine kinase (CK and CK-MB due to its high sensitivity and specificity for the detection of myocardial injury. Cardiac troponins are proteins that control the calcium-mediated interaction between actin and myosin, allowing contraction at the sarcomere level. Concentration of the cTn can be correlated microscopic lesion and loss of immunolabeling in myocardium damage. Troponin concentration remains elevated in blood for 1-2wks so that wide window is available for diagnosis of myocardial damage. The cTn test has >95% specificity and sensitivity and test is less time consuming (10 to 15 minutes and less costly (INR 200 to INR 500. [Vet. World 2012; 5(8.000: 508-511

  20. A Distance Function Model with Good and Bad Outputs

    OpenAIRE

    2014-01-01

    We present an approach that pursues an adequate representation of product transformation possibilities for a technology generating, in addition to marketed (good) products, some environmentally detrimental non-marketed byproducts (bad outputs). As the shadow price of a non-marketed output depends on its marginal transformation rates with marketed outputs, representation of technological relationships between different groups of outputs deserves a particular attention. We model the technology ...

  1. Equivalence of Nonlinear Systems to Input-Output Prime Forms

    OpenAIRE

    Marino, R.; Respondek, W.; van der Schaft, A. J.

    1994-01-01

    The problem of transforming nonlinear control systems into input-output prime forms is dealt with, using state space, static state feedback, and also output space transformations. Necessary and sufficient geometric conditions for the solvability of this problem are obtained. The results obtained generalize well-known results both on feedback linearization as well as input-output decoupling of nonlinear systems. It turns out that, from a computational point of view, the output space transforma...

  2. Regional Input Output Table for the State of Punjab

    OpenAIRE

    Singh, Inderjeet; Singh, Lakhwinder

    2011-01-01

    Because of policy relevance of regional input-output analysis, a vast literature on the construction of regional input-output tables has emerged in the recent past, especially on the non-survey and hybrid methods. Although, construction of regional input-output tables is not new in India, but generation of input-output table using non-survey methods is relatively a rare phenomenon. This work validates alternative non-survey, location quotient methodologies and finally uses comparatively bette...

  3. STABILITY ANALYSIS OF THE DYNAMIC INPUT-OUTPUT SYSTEM

    Institute of Scientific and Technical Information of China (English)

    GuoChonghui; TangHuanwen

    2002-01-01

    The dynamic input-output model is well known in economic theory and practice. In this paper, the asymptotic stability and balanced growth solutions of the dynamic input-output system are considered. Under some natural assumptions which do not require the technical coefficient matrix to be indecomposable,it has been proved that the dynamic input-output system is not asymptotically stable and the closed dynamic input-output model has a balanced growth solution.

  4. Waste treatment in physical input-output analysis

    NARCIS (Netherlands)

    Dietzenbacher, E

    2005-01-01

    When compared to monetary input-output tables (MIOTs), a distinctive feature of physical input-output tables (PIOTs) is that they include the generation of waste as part of a consistent accounting framework. As a consequence, however, physical input-output analysis thus requires that the treatment o

  5. REFLECTIONS ON THE INOPERABILITY INPUT-OUTPUT MODEL

    NARCIS (Netherlands)

    Dietzenbacher, Erik; Miller, Ronald E.

    2015-01-01

    We argue that the inoperability input-output model is a straightforward - albeit potentially very relevant - application of the standard input-output model. In addition, we propose two less standard input-output approaches as alternatives to take into consideration when analyzing the effects of disa

  6. TEE-guided left ventricular epicardial pacing lead placement for cardiac resynchronization therapy

    Directory of Open Access Journals (Sweden)

    Rajesh Chand Arya

    2012-01-01

    Full Text Available Biventricular pacing has demonstrated improvement in cardiac functions in treating congestive cardiac failure patients. Recent trials have proven the clinical and functional benefits of cardiac resynchronization therapy in severe heart failure and intraventricular cardiac delays, mainly left bundle branch block. Biventricular pacing improves the exercise tolerance, quality of life, systolic heart function, reduces hospitalization and slows progression of the disease. A 54-year-old lady, a known case of dilated cardiomyopathy, was on biventricular pacing since 2 years. She presented in emergency with sudden deterioration of dyspnea to NYHA class III/IV. When investigated, the coronary sinus lead was found displaced; thus, left ventricle (LV was not getting paced. After multiple failures to reposition the coronary sinus lead, it was decided to surgically place the epicardial lead for LV pacing under general anesthesia. Lateral thoracotomy was done and LV pacing lead was placed at different sites with simultaneous monitoring of cardiac output (CO and stroke volume (SV by transesophageal echocardiography (TEE. Baseline CO and SV were 1.9 l/min and 19.48 ml respectively and increased at different sites of pacing at LV, the best CO and SV were 4.2 l/min and 42.39 ml respectively on lateral surface. Intraoperative TEE can calculate beat to beat stroke volume and thus CO and helps to choose optimal site for placement of epicardial pacing lead.

  7. Renal and cardiac neuropeptide Y and NPY receptors in a rat model of congestive heart failure.

    Science.gov (United States)

    Callanan, Ean Y; Lee, Edward W; Tilan, Jason U; Winaver, Joseph; Haramati, Aviad; Mulroney, Susan E; Zukowska, Zofia

    2007-12-01

    Neuropeptide Y (NPY) is coreleased with norepinephrine and stimulates vasoconstriction, vascular and cardiomyocyte hypertrophy via Y1 receptors (R) and angiogenesis via Y2R. Although circulating NPY is elevated in heart failure, NPY's role remains unclear. Activation of the NPY system was determined in Wistar rats with the aortocaval (A-V) fistula model of high-output heart failure. Plasma NPY levels were elevated in A-V fistula animals (115.7 +/- 15.3 vs. 63.1 +/- 17.4 pM in sham, P renal failure (urinary Na(+) excretion renal blood flow (RBF), and death within 5-7 days (DECOMP). Cardiac and renal tissue NPY decreased with heart failure, proportionate to the severity of renal complications. Cardiac and renal Y1R mRNA expression also decreased (1.5-fold, P failure. In contrast, Y2R expression increased up to 72-fold in the heart and 5.7-fold in the kidney (P failure and cardiac hypertrophy. Changes in receptor expression were confirmed since the Y1R agonist, [Leu31, Pro34]-NPY, had no effect on RBF, whereas the Y2R agonist (13-36)-NPY increased RBF to compensate for disease. Thus, in this model of heart failure, cardiac and renal NPY Y1 receptors decrease and Y2 receptors increase, suggesting an increased effect of NPY on the receptors involved in cardiac remodeling and angiogenesis, and highlighting an important regulatory role of NPY in congestive heart failure.

  8. [Cardiac cephalgia: an underdiagnosed condition? ].

    Science.gov (United States)

    Gutiérrez Morlote, Jesús; Fernández García, José M; Timiraos Fernández, Juan J; Llano Cardenal, Miguel; Llano Catedral, Miguel; Rodríguez Rodríguez, Eloy; Pascual Gómez, Julio

    2005-12-01

    Cardiac cephalgia, or headache occurring as manifestation of myocardial ischemia, has only recently been recognized as a distinct entity. In patients with known ischemic cardiopathy, its diagnosis depends on the presence of severe headache that is accompanied by nausea, worsened by physical exercise, and only ceases with nitrate administration. We report on two patients who met diagnostic criteria for this entity. In both, headache was the only symptom of coronary ischemia, and delayed its diagnosis. Headache occurred both at rest and during exertion, and resolved only after the administration of nitrates. Cardiac cephalgia should be suspected in patients with a history of ischemic cardiopathy who present with de novo headache, even when thoracic pain is absent, especially if the headache improves with nitrates. Differential diagnosis with migraine is crucial to avoid the administration of vasoconstrictors.

  9. [Cardiac toxicity of 5-fluorouracil].

    Science.gov (United States)

    Fournier, C; Benahmed, M; Blondeau, M

    1989-02-01

    A 67 year-old patient receives 5-fluorouracil for vocal chord cancer. During the perfusion, atypical angina pain occurs, accompanied with offset of ST above the baseline in standard leads and in V4 through V6. The pain subsides spontaneously in 45 minutes. These ECG alterations are followed 48 hours later by diffuse inverted T waves with lengthened QT. Cardiac ultrasonography and isotopic angiography do not show any abnormality of the left ventricular function, but myocardial tomoscintigraphy with labelled thallium show a lower hypofixation on exertion. The cardiac toxicity of 5-fluorouracil is in frequent. It is usually believed that it involves a coronary spasm, as suggested by the ECG tracing in the reported cases. The incident, which may be painful or painless, may result in a myocardial infarction or even sudden death during the perfusion. Therefore, it is advisable to discontinue the treatment as soon as an angina-type pain occurs.

  10. Progeria syndrome with cardiac complications.

    Science.gov (United States)

    Ilyas, Saadia; Ilyas, Hajira; Hameed, Abdul; Ilyas, Muhammad

    2013-09-01

    A case report of 6-year-old boy with progeria syndrome, with marked cardiac complications is presented. The boy had cardiorespiratory failure. Discoloured purpuric skin patches, alopecia, prominent forehead, protuberant eyes, flattened nasal cartilage, malformed mandible, hypodentition, and deformed rigid fingers and toes were observed on examination. The boy was unable to speak. A sclerotic systolic murmur was audible over the mitral and aortic areas. Chest x-rays showed cardiac enlargement and the electrocardiogram (ECG) showed giant peaked P waves (right atrial hypertrophy) and right ventricular hypertrophy. Atherosclerotic dilated ascending aorta, thickened sclerotic aortic, mitral, and tricuspid valves with increased echo texture, left and right atrial and right ventricular dilatation, reduced left ventricular cavity, and thickened speckled atrial and ventricular septa were observed on echocardiography.

  11. Sudden cardiac death in athletes

    Directory of Open Access Journals (Sweden)

    Fábio Camilo Pellegrino dos Santos

    2012-11-01

    Full Text Available ABSTRACT The most accepted definition of sudden cardiac death nowadays is an unexplained death occurred suddenly within one hour of symptom onset. If it was not witnessed, individuals need to had been observed for at least 24 hours before the event and should be discarded the possibility of non cardiac causes of sudden death, pulmonary embolism or extensive malignancy. The term athlete refers to individuals of any age who participate in collective or individual regular physical activity, as well as physical training program for regular competitions. The sudden death of a young athlete, whether amateur or professional, especially during competitions, is always dramatic, with strong negative social impact and in the media. The fact that sports are recommended as a formula for longevity and quality of life makes these events a cause for concern in sports and society in general.

  12. Heart fields and cardiac morphogenesis.

    Science.gov (United States)

    Kelly, Robert G; Buckingham, Margaret E; Moorman, Antoon F

    2014-10-01

    In this review, we focus on two important steps in the formation of the embryonic heart: (i) the progressive addition of late differentiating progenitor cells from the second heart field that drives heart tube extension during looping morphogenesis, and (ii) the emergence of patterned proliferation within the embryonic myocardium that generates distinct cardiac chambers. During the transition between these steps, the major site of proliferation switches from progenitor cells outside the early heart to proliferation within the embryonic myocardium. The second heart field and ballooning morphogenesis concepts have major repercussions on our understanding of human heart development and disease. In particular, they provide a framework to dissect the origin of congenital heart defects and the regulation of myocardial proliferation and differentiation of relevance for cardiac repair.

  13. Respiratory gating in cardiac PET

    DEFF Research Database (Denmark)

    Lassen, Martin Lyngby; Rasmussen, Thomas; Christensen, Thomas E

    2016-01-01

    of our study was to compare the resulting imaging quality by the use of a time-based respiratory gating system in two groups administered either adenosine or dipyridamole as the pharmacological stress agent. METHODS AND RESULTS: Forty-eight patients were randomized to adenosine or dipyridamole cardiac...... stress (82)RB-PET. Respiratory rates and depths were measured by a respiratory gating system in addition to registering actual respiratory rates. Patients undergoing adenosine stress showed a decrease in measured respiratory rate from initial to later scan phase measurements [12.4 (±5.7) vs 5.6 (±4......BACKGROUND: Respiratory motion due to breathing during cardiac positron emission tomography (PET) results in spatial blurring and erroneous tracer quantification. Respiratory gating might represent a solution by dividing the PET coincidence dataset into smaller respiratory phase subsets. The aim...

  14. Systems biology and cardiac arrhythmias.

    Science.gov (United States)

    Grace, Andrew A; Roden, Dan M

    2012-10-27

    During the past few years, the development of effective, empirical technologies for treatment of cardiac arrhythmias has exceeded the pace at which detailed knowledge of the underlying biology has accumulated. As a result, although some clinical arrhythmias can be cured with techniques such as catheter ablation, drug treatment and prediction of the risk of sudden death remain fairly primitive. The identification of key candidate genes for monogenic arrhythmia syndromes shows that to bring basic biology to the clinic is a powerful approach. Increasingly sophisticated experimental models and methods of measurement, including stem cell-based models of human cardiac arrhythmias, are being deployed to study how perturbations in several biologic pathways can result in an arrhythmia-prone heart. The biology of arrhythmia is largely quantifiable, which allows for systematic analysis that could transform treatment strategies that are often still empirical into management based on molecular evidence.

  15. Nutritional Status and Cardiac Autophagy

    Directory of Open Access Journals (Sweden)

    Jihyun Ahn

    2013-02-01

    Full Text Available Autophagy is necessary for the degradation of long-lasting proteins and nonfunctional organelles, and is activated to promote cellular survival. However, overactivation of autophagy may deplete essential molecules and organelles responsible for cellular survival. Lifelong calorie restriction by 40% has been shown to increase the cardiac expression of autophagic markers, which suggests that it may have a cardioprotective effect by decreasing oxidative damage brought on by aging and cardiovascular diseases. Although cardiac autophagy is critical to regulating protein quality and maintaining cellular function and survival, increased or excessive autophagy may have deleterious effects on the heart under some circumstances, including pressure overload-induced heart failure. The importance of autophagy has been shown in nutrient supply and preservation of energy in times of limitation, such as ischemia. Some studies have suggested that a transition from obesity to metabolic syndrome may involve progressive changes in myocardial inflammation, mitochondrial dysfunction, fibrosis, apoptosis, and myocardial autophagy.

  16. Pregnancy as a cardiac stress model.

    Science.gov (United States)

    Chung, Eunhee; Leinwand, Leslie A

    2014-03-15

    Cardiac hypertrophy occurs during pregnancy as a consequence of both volume overload and hormonal changes. Both pregnancy- and exercise-induced cardiac hypertrophy are generally thought to be similar and physiological. Despite the fact that there are shared transcriptional responses in both forms of cardiac adaptation, pregnancy results in a distinct signature of gene expression in the heart. In some cases, however, pregnancy can induce adverse cardiac events in previously healthy women without any known cardiovascular disease. Peripartum cardiomyopathy is the leading cause of non-obstetric mortality during pregnancy. To understand how pregnancy can cause heart disease, it is first important to understand cardiac adaptation during normal pregnancy. This review provides an overview of the cardiac consequences of pregnancy, including haemodynamic, functional, structural, and morphological adaptations, as well as molecular phenotypes. In addition, this review describes the signalling pathways responsible for pregnancy-induced cardiac hypertrophy and angiogenesis. We also compare and contrast cardiac adaptation in response to disease, exercise, and pregnancy. The comparisons of these settings of cardiac hypertrophy provide insight into pregnancy-associated cardiac adaptation.

  17. CARDIAC TRANSPLANTATION: AN ANESTHETIC CHALLENGE

    Directory of Open Access Journals (Sweden)

    Premalatha

    2014-05-01

    Full Text Available : Heart transplantation has emerged as the definitive therapy for patients with end-stage cardiomyopathy. The two most common forms of cardiac disease that lead to transplantation are ischemic cardiomyopathy and dilated cardiomyopathy, which together comprise approximately 90% of cases. The other less common forms of heart disease include viral cardiomyopathy, infiltrative cardiomyopathy, postpartum cardiomyopathy, valvular heart disease and congenital heart disease

  18. Chaos control of cardiac arrhythmias.

    Science.gov (United States)

    Garfinkel, A; Weiss, J N; Ditto, W L; Spano, M L

    1995-01-01

    Chaos theory has shown that many disordered and erratic phenomena are in fact deterministic, and can be understood causally and controlled. The prospect that cardiac arrhythmias might be instances of deterministic chaos is therefore intriguing. We used a recently developed method of chaos control to stabilize a ouabain-induced arrhythmia in rabbit ventricular tissue in vitro. Extension of these results to clinically significant arrhythmias such as fibrillation will require overcoming the additional obstacles of spatiotemporal complexity.

  19. Cardiac autonomic nerve distribution and arrhythmia

    Institute of Scientific and Technical Information of China (English)

    Quan Liu; Dongmei Chen; Yonggang Wang; Xin Zhao; Yang Zheng

    2012-01-01

    OBJECTIVE: To analyze the distribution characteristics of cardiac autonomic nerves and to explore the correlation between cardiac autonomic nerve distribution and arrhythmia.DATA RETRIEVAL: A computer-based retrieval was performed for papers examining the distribution of cardiac autonomic nerves, using "heart, autonomic nerve, sympathetic nerve, vagus nerve, nerve distribution, rhythm and atrial fibrillation" as the key words.SELECTION CRITERIA: A total of 165 studies examining the distribution of cardiac autonomic nerve were screened, and 46 of them were eventually included.MAIN OUTCOME MEASURES: The distribution and characteristics of cardiac autonomic nerves were observed, and immunohistochemical staining was applied to determine the levels of tyrosine hydroxylase and acetylcholine transferase (main markers of cardiac autonomic nerve distribution). In addition, the correlation between cardiac autonomic nerve distribution and cardiac arrhythmia was investigated.RESULTS: Cardiac autonomic nerves were reported to exhibit a disordered distribution in different sites, mainly at the surface of the cardiac atrium and pulmonary vein, forming a ganglia plexus. The distribution of the pulmonary vein autonomic nerve was prominent at the proximal end rather than the distal end, at the upper left rather than the lower right, at the epicardial membrane rather than the endocardial membrane, at the left atrium rather than the right atrium, and at the posterior wall rather than the anterior wall. The main markers used for cardiac autonomic nerves were tyrosine hydroxylase and acetylcholine transferase. Protein gene product 9.5 was used to label the immunoreactive nerve distribution, and the distribution density of autonomic nerves was determined using a computer-aided morphometric analysis system.CONCLUSION: The uneven distribution of the cardiac autonomic nerves is the leading cause of the occurrence of arrhythmia, and the cardiac autonomic nerves play an important role in the

  20. Mechanical modulation of cardiac microtubules.

    Science.gov (United States)

    White, Ed

    2011-07-01

    Microtubules are a major component of the cardiac myocyte cytoskeleton. Interventions that alter it may influence cardiac mechanical and electrical activity by disrupting the trafficking of proteins to and from the surface membrane by molecular motors such as dynein, which use microtubules as tracks to step along. Free tubulin dimers may transfer GTP to the α-subunits of G-proteins, thus an increase in free tubulin could increase the activity of G-proteins; evidence for and against such a role exists. There is more general agreement that microtubules act as compression-resisting structures within myocytes, influencing visco-elasticity of myocytes and increasing resistance to shortening when proliferated and resisting deformation from longitudinal shear stress. In response to pressure overload, there can be post-translational modifications resulting in more stable microtubules and an increase in microtubule density. This is accompanied by contractile dysfunction of myocytes which can be reversed by microtubule disruption. There are reports of mechanically induced changes in electrical activity that are dependent upon microtubules, but at present, a consensus is lacking on whether disruption or proliferation would be beneficial in the prevention of arrhythmias. Microtubules certainly play a role in the response of cardiac myocytes to mechanical stimulation, the exact nature and significance of this role is still to be fully determined.

  1. Review Article of Cardiac Amyloidosis

    Directory of Open Access Journals (Sweden)

    Jittiporn PURATTANAMAL

    2010-06-01

    Full Text Available Cardiac amyloidosis is a term that means the deposit of abnormal proteins in the myocardium leading to global thickening of the heart walls. The clinical character is that of infiltrative cardiomyopathy. AL amyloidosis is the most common type that involves cardiac failure. Cardiac amyloid precedes clinical congestive heart failure, especially right-sided heart failure. Laboratory investigations have identified the amyloid fibril proteins deposited in the organ tissues. Immunofixation tests are the most sensitive that recognize the paraprotein mean light chain protein or immunoglobulin subtype deposit. Prognosis is poor if AL amyloidosis is untreated. Treatment of systemic involvement in AL amyloidosis is via chemotherapy such as melphalan and prednisolone. UK experts have reported the results of treatment in AL amyloidosis. Regardless of the use of adjunctive chemotherapy, the five-year survival after heart transplantation was generally poorer for AL (20 % at five years, but similar for non-AL amyloidosis (64 % at five years, than heart transplants in other cases. Progression of the systemic disease contributed to increased mortality. A specific treatment that increases the chances of survival is unknown.

  2. Sudden cardiac death risk stratification.

    Science.gov (United States)

    Deyell, Marc W; Krahn, Andrew D; Goldberger, Jeffrey J

    2015-06-01

    Arrhythmic sudden cardiac death (SCD) may be caused by ventricular tachycardia/fibrillation or pulseless electric activity/asystole. Effective risk stratification to identify patients at risk of arrhythmic SCD is essential for targeting our healthcare and research resources to tackle this important public health issue. Although our understanding of SCD because of pulseless electric activity/asystole is growing, the overwhelming majority of research in risk stratification has focused on SCD-ventricular tachycardia/ventricular fibrillation. This review focuses on existing and novel risk stratification tools for SCD-ventricular tachycardia/ventricular fibrillation. For patients with left ventricular dysfunction or myocardial infarction, advances in imaging, measures of cardiac autonomic function, and measures of repolarization have shown considerable promise in refining risk. Yet the majority of SCD-ventricular tachycardia/ventricular fibrillation occurs in patients without known cardiac disease. Biomarkers and novel imaging techniques may provide further risk stratification in the general population beyond traditional risk stratification for coronary artery disease alone. Despite these advances, significant challenges in risk stratification remain that must be overcome before a meaningful impact on SCD can be realized.

  3. Neurologic management following cardiac arrest.

    Science.gov (United States)

    Bircher, N G

    1989-10-01

    Optimal neurologic outcome after cardiac arrest requires careful attention to the details of both intracranial and extracranial homeostasis. A high index of suspicion regarding the potential causes and complications of cardiac arrest facilitates discovery and treatment of problems before they adversely affect neurologic outcome. The future is bright for resuscitation research: Our fundamental understanding of cerebral ischemia and its consequences has dramatically improved, and this knowledge can hopefully be transferred to clinical useful modes of therapy. However, the transition from a promising, therapeutically effective intervention in animals to the demonstration that treatment is effective following cardiac arrest in humans is an important and difficult step. The patient population is heterogeneous before the insult, the duration and severity of the insult are variable, and the effectiveness of cardiopulmonary resuscitation varies among institutions. Therefore, the only means of demonstrating clinical efficacy is the performance of a large clinical trial. The Resuscitation Research Center at the University of Pittsburgh has developed and coordinated a multicenter, multinational team of investigators who have completed one definitive trial of postarrest barbiturate therapy and are currently completing a similar trial using a calcium entry blocker. Despite the formidable obstacles posed by such comprehensive efforts, they provide the mechanism for determining whether the cost of a new treatment modality is justified by the likelihood of improved mortality or morbidity.

  4. Inherited arrhythmias: The cardiac channelopathies

    Directory of Open Access Journals (Sweden)

    Shashank P Behere

    2015-01-01

    Full Text Available Ion channels in the myocardial cellular membrane are responsible for allowing the cardiac action potential. Genetic abnormalities in these channels can predispose to life-threatening arrhythmias. We discuss the basic science of the cardiac action potential; outline the different clinical entities, including information regarding overlapping diagnoses, touching upon relevant genetics, new innovations in screening, diagnosis, risk stratification, and management. The special considerations of sudden unexplained death and sudden infant death syndrome are discussed. Scientists and clinicians continue to reconcile the rapidly growing body of knowledge regarding the molecular mechanisms and genetics while continuing to improve our understanding of the various clinical entities and their diagnosis and management in clinical setting. Two separate searches were run on the National Center for Biotechnology Information′s website. The first using the term cardiac channelopathies was run on the PubMed database using filters for time (published in past 5 years and age (birth-18 years, yielding 47 results. The second search using the medical subject headings (MeSH database with the search terms "Long QT Syndrome" (MeSH and "Short QT Syndrome" (MeSH and "Brugada Syndrome" (MeSH and "Catecholaminergic Polymorphic Ventricular Tachycardia" (MeSH, applying the same filters yielded 467 results. The abstracts of these articles were studied, and the articles were categorized and organized. Articles of relevance were read in full. As and where applicable, relevant references and citations from the primary articles where further explored and read in full.

  5. Hybrid optoelectronic device with multiple bistable outputs

    Science.gov (United States)

    Costazo-Caso, Pablo A.; Jin, Yiye; Gelh, Michael; Granieri, Sergio; Siahmakoun, Azad

    2011-01-01

    Optoelectronic circuits which exhibit optical and electrical bistability with hysteresis behavior are proposed and experimentally demonstrated. The systems are based on semiconductor optical amplifiers (SOA), bipolar junction transistors (BJT), PIN photodiodes (PD) and laser diodes externally modulated with integrated electro-absorption modulators (LD-EAM). The device operates based on two independent phenomena leading to both electrical bistability and optical bistability. The electrical bistability is due to the series connection of two p-i-n structures (SOA, BJT, PD or LD) in reverse bias. The optical bistability is consequence of the quantum confined Stark effect (QCSE) in the multi-quantum well (MQW) structure in the intrinsic region of the device. This effect produces the optical modulation of the transmitted light through the SOA (or reflected from the PD). Finally, because the optical transmission of the SOA (in reverse bias) and the reflected light from the PD are so small, a LD-EAM modulated by the voltage across these devices are employed to obtain a higher output optical power. Experiments show that the maximum switching frequency is in MHz range and the rise/fall times lower than 1 us. The temporal response is mainly limited by the electrical capacitance of the devices and the parasitic inductances of the connecting wires. The effects of these components can be reduced in current integration technologies.

  6. Experimental Investigation on Power Output in Aged Wind Turbines

    Directory of Open Access Journals (Sweden)

    N. Murugan

    2012-01-01

    Full Text Available An investigation on the power output on effect of tower height with same diameter of rotor was conducted in a wind turbine site. As the wind acceleration is varying with height, 3 levels were selected according to the availability of tower. The responses of power output with respect to variation of wind speed are changing for the tower heights of 30, 40, and 50 m. The study showed that the actual ideal power output and measured real power output follow the same trend within range of operating wind speed. The empirical model used for calculation of actual ideal power output was compared with real power output and the overall concepts in power output also had been analysed.

  7. Cardiac molecular-acclimation mechanisms in response to swimming-induced exercise in Atlantic salmon.

    Directory of Open Access Journals (Sweden)

    Vicente Castro

    Full Text Available Cardiac muscle is a principal target organ for exercise-induced acclimation mechanisms in fish and mammals, given that sustained aerobic exercise training improves cardiac output. Yet, the molecular mechanisms underlying such cardiac acclimation have been scarcely investigated in teleosts. Consequently, we studied mechanisms related to cardiac growth, contractility, vascularization, energy metabolism and myokine production in Atlantic salmon pre-smolts resulting from 10 weeks exercise-training at three different swimming intensities: 0.32 (control, 0.65 (medium intensity and 1.31 (high intensity body lengths s(-1. Cardiac responses were characterized using growth, immunofluorescence and qPCR analysis of a large number of target genes encoding proteins with significant and well-characterized function. The overall stimulatory effect of exercise on cardiac muscle was dependent on training intensity, with changes elicited by high intensity training being of greater magnitude than either medium intensity or control. Higher protein levels of PCNA were indicative of cardiac growth being driven by cardiomyocyte hyperplasia, while elevated cardiac mRNA levels of MEF2C, GATA4 and ACTA1 suggested cardiomyocyte hypertrophy. In addition, up-regulation of EC coupling-related genes suggested that exercised hearts may have improved contractile function, while higher mRNA levels of EPO and VEGF were suggestive of a more efficient oxygen supply network. Furthermore, higher mRNA levels of PPARα, PGC1α and CPT1 all suggested a higher capacity for lipid oxidation, which along with a significant enlargement of mitochondrial size in cardiac myocytes of the compact layer of fish exercised at high intensity, suggested an enhanced energetic support system. Training also elevated transcription of a set of myokines and other gene products related to the inflammatory process, such as TNFα, NFκB, COX2, IL1RA and TNF decoy receptor. This study provides the first

  8. The role of adrenergic stimulation in maintaining maximum cardiac performance in rainbow trout (Oncorhynchus mykiss) during hypoxia, hyperkalemia and acidosis at 10 degrees C.

    Science.gov (United States)

    Hanson, Linda M; Obradovich, Shannon; Mouniargi, Janet; Farrell, Anthony P

    2006-07-01

    As rainbow trout approach exhaustion during prolonged exercise, they maintain maximum cardiac output despite the fact their venous blood, which bathes the heart, becomes hypoxic, acidotic and hyperkalemic. Because these factors are individually recognized to have detrimental inotropic and chronotropic effects on cardiac performance, we hypothesized that adrenergic stimulation is critical in maintaining maximum cardiac performance under these collectively adverse conditions in vivo. To test this hypothesis, maximum cardiac performance in the presence and absence of maximal adrenergic stimulation was assessed with in situ rainbow trout hearts using relevant hyperkalemic (5.0 mmol l(-1) K+), acidotic (pH 7.5) and hypoxic challenges. With tonic adrenergic stimulation (5.0 nmol l(-1) adrenaline), hearts produced only 44.8+/-14.6% of their normal maximum cardiac output when exposed under normoxic conditions (20 kPa) to the hyperkalemic, acidotic perfusate, indicating that in vivo there was no refuge from cardiac impairment even if venous blood was fully oxygenated. By contrast, maximum adrenergic stimulation (500 nmol l(-1) adrenaline), fully protected maximum cardiac performance under hyperkalemic and acidotic conditions over a wide range of oxygen availability, from normoxia to 2.0 kPa, a venous oxygen tension close to routine values in vivo. Extending the level of hypoxia to 1.3 kPa resulted in a 43.6+/-2.8% decrease in maximum cardiac output, with hearts failing when tested at 1.0 kPa. Our results suggest that adrenergic stimulation of the trout heart is critical in maintaining maximum performance during prolonged swimming tests, and probably during all forms of exhaustive activity and recovery, when venous blood is hyperkalemic, acidotic and hypoxic.

  9. Cardiac tamponade: contrast reflux as an indicator of cardiac chamber equalization

    Directory of Open Access Journals (Sweden)

    Nauta Foeke Jacob

    2012-05-01

    Full Text Available Abstract Background Traumatic hemopericardium remains a rare entity; it does however commonly cause cardiac tamponade which remains a major cause of death in traumatic blunt cardiac injury. Objectives We present a case of blunt chest trauma complicated by cardiac tamponade causing cardiac chamber equalization revealed by reflux of contrast. Case report A 29-year-old unidentified male suffered blunt chest trauma in a motor vehicle collision. Computed tomography (CT demonstrated a periaortic hematoma and hemopericardium. Significant contrast reflux was seen in the inferior vena cava and hepatic veins suggesting a change in cardiac chamber pressures. After intensive treatment including cardiac massage this patient expired of cardiac arrest. Conclusion Reflux of contrast on CT imaging can be an indicator of traumatic cardiac tamponade.

  10. Sensing Cardiac Electrical Activity With a Cardiac Myocyte--Targeted Optogenetic Voltage Indicator

    NARCIS (Netherlands)

    Chang Liao, Mei-Ling; de Boer, Teun P; Mutoh, Hiroki; Raad, Nour; Richter, Claudia; Wagner, Eva; Downie, Bryan R; Unsöld, Bernhard; Arooj, Iqra; Streckfuss-Bömeke, Katrin; Döker, Stephan; Luther, Stefan; Guan, Kaomei; Wagner, Stefan; Lehnart, Stephan E; Maier, Lars S; Stühmer, Walter; Wettwer, Erich; van Veen, Toon; Morlock, Michael M; Knöpfel, Thomas; Zimmermann, Wolfram-Hubertus

    2015-01-01

    RATIONALE: Monitoring and controlling cardiac myocyte activity with optogenetic tools offer exciting possibilities for fundamental and translational cardiovascular research. Genetically encoded voltage indicators may be particularly attractive for minimal invasive and repeated assessments of cardiac

  11. Cognitive impairment after sudden cardiac arrest

    OpenAIRE

    Jaszke-Psonka, Magdalena; Piegza, Magdalena; Ścisło, Piotr; Pudlo, Robert; Piegza, Jacek; Badura-Brzoza, Karina; Leksowska, Aleksandra; Hese, Robert T.; Gorczyca, Piotr W.

    2016-01-01

    Aim To evaluate the incidence and severity of the impairment of selected cognitive functions in patients after sudden cardiac arrest (SCA) in comparison to patients after myocardial infarction without SCA and healthy subjects and to analyze the influence of sociodemographic and clinical parameters and the duration of cardiac arrest on the presence and severity of the described disorders. Material and methods The study group comprised 30 cardiac arrest survivors, the reference group comprised ...

  12. Surgical resection of a giant cardiac fibroma.

    Science.gov (United States)

    Stamp, Nikki L; Larbalestier, Robert I

    2016-05-01

    A 42-year-old woman presented to a regional hospital emergency room with palpitations and was found to be in ventricular tachycardia. Chest radiography demonstrated a massively enlarged cardiac silhouette. Echocardiography and cardiac magnetic resonance imaging demonstrated a mass within the left ventricular free wall, consistent with a cardiac fibroma. The patient proceeded to have surgical resection of the mass. Left ventricular function was preserved postoperatively.

  13. Activation of cardiac ryanodine receptors by cardiac glycosides.

    Science.gov (United States)

    Sagawa, Toshio; Sagawa, Kazuko; Kelly, James E; Tsushima, Robert G; Wasserstrom, J Andrew

    2002-03-01

    This study investigated the effects of cardiac glycosides on single-channel activity of the cardiac sarcoplasmic reticulum (SR) Ca2+ release channels or ryanodine receptor (RyR2) channels and how this action might contribute to their inotropic and/or toxic actions. Heavy SR vesicles isolated from canine left ventricle were fused with artificial planar lipid bilayers to measure single RyR2 channel activity. Digoxin and actodigin increased single-channel activity at low concentrations normally associated with therapeutic plasma levels, yielding a 50% of maximal effect of approximately 0.2 nM for each agent. Channel activation by glycosides did not require MgATP and occurred only when digoxin was applied to the cytoplasmic side of the channel. Similar results were obtained in human RyR2 channels; however, neither the crude skeletal nor the purified cardiac channel was activated by glycosides. Channel activation was dependent on [Ca2+] on the luminal side of the bilayer with maximal stimulation occurring between 0.3 and 10 mM. Rat RyR2 channels were activated by digoxin only at 1 microM, consistent with the lower sensitivity to glycosides in rat heart. These results suggest a model in which RyR2 channel activation by digoxin occurs only when luminal [Ca2+] was increased above 300 microM (in the physiological range). Consequently, increasing SR load (by Na+ pump inhibition) serves to amplify SR release by promoting direct RyR2 channel activation via a luminal Ca2+-sensitive mechanism. This high-affinity effect of glycosides could contribute to increased SR Ca2+ release and might play a role in the inotropic and/or toxic actions of glycosides in vivo.

  14. Cardiac Arrhythmias: Diagnosis, Symptoms, and Treatments.

    Science.gov (United States)

    Fu, Du-Guan

    2015-11-01

    The cardiac arrhythmia is characterized by irregular rhythm of heartbeat which could be either too slow (100 beats/min) and can happen at any age. The use of pacemaker and defibrillators devices has been suggested for heart arrhythmias patients. The antiarrhythmic medications have been reported for the treatment of cardiac arrhythmias or irregular heartbeats. The diagnosis, symptoms, and treatments of cardiac arrhythmias as well as the radiofrequency ablation, tachycardia, Brugada syndrome, arterial fibrillation, and recent research on the genetics of cardiac arrhythmias have been described here.

  15. Multimodality imaging for resuscitated sudden cardiac death.

    Science.gov (United States)

    Chen, Yingming Amy; Deva, Djeven; Kirpalani, Anish; Prabhudesai, Vikram; Marcuzzi, Danny W; Graham, John J; Verma, Subodh; Jimenez-Juan, Laura; Yan, Andrew T

    2015-01-01

    We present a case that elegantly illustrates the utility of two novel noninvasive imaging techniques, computed tomography (CT) coronary angiography and cardiac MRI, in the diagnosis and management of a 27-year-old man with exertion-induced cardiac arrest caused by an anomalous right coronary artery. CT coronary angiography with 3D reformatting delineated the interarterial course of an anomalous right coronary artery compressed between the aorta and pulmonary artery, whereas cardiac MRI showed a small myocardial infarction in the right coronary artery territory not detected on echocardiography. This case highlights the value of novel multimodality imaging techniques in the risk stratification and management of patients with resuscitated cardiac arrest.

  16. Input/output plugin architecture for MDSplus

    Energy Technology Data Exchange (ETDEWEB)

    Stillerman, Joshua, E-mail: jas@psfc.mit.edu [Massachusetts Institute of Technology, 175 Albany Street, Cambridge, MA 02139 (United States); Fredian, Thomas, E-mail: twf@psfc.mit.edu [Massachusetts Institute of Technology, 175 Albany Street, Cambridge, MA 02139 (United States); Manduchi, Gabriele, E-mail: gabriele.manduchi@igi.cnr.it [Consorzio RFX, Euratom-ENEA Association, Corso Stati Uniti 4, Padova 35127 (Italy)

    2014-05-15

    The first version of MDSplus was released in 1991 for VAX/VMS. Since that time the underlying file formats have remained constant. The software however has evolved, it was ported to unix, linux, Windows, and Macintosh. In 1997 a TCP based protocol, mdsip, was added to provide network access to MDSplus data. In 2011 a mechanism was added to allow protocol plugins to permit the use of other transport mechanisms such as ssh to access data users. This paper describes a similar design which permits the insertion of plugins to handle the reading and writing of MDSplus data at the data storage level. Tree paths become URIs which specify the protocol, host, and protocol specific information. The protocol is provided by a dynamically activated shared library that can provide any consistent subset of the data store access API, treeshr. The existing low level network protocol called mdsip, is activated by defining tree paths like “host::/directory”. Using the new plugin mechanism this is re-implemented as an instance of the general plugin that replaces the low level treeshr input/output routines. It is specified by using a path like “mdsip://host/directory”. This architecture will make it possible to adapt the MDSplus data organization and analysis tools to other underlying data storage. The first new application of this, after the existing network protocol is implemented, will be a plugin based on a key value store. Key value stores, can provide inexpensive scalable, redundant data storage. An example of this might be an Amazon G3 plugin which would let you specify a tree path such as “AG3://container” to access MDSplus data stored in the cloud.

  17. Assessment of paediatric hydronephrosis using output efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Saundres, C.A.B.; Choong, K.K.L.; Gruenewald, S.M. [Westmead Hospital, Westmead, NSW (Australia). Dept of Nuclear Medicine

    1998-03-01

    Full text: Diuretic renography is an important tool in the evaluation of paediatric hydronephrosis. Recently a newly developed parameter, output efficiency (OE) has allowed normalisation of washout according to renal function. We retrospectively reviewed the diagnostic accuracy of OE in 56 children (70 hydronephrotic kidneys). There were 16 females and 41 males (mean age 1.4 years, range 3 weeks-12 years). Diuretic renography ({sup 99m}Tc-MAG3) was performed using i.v. volume expansion (15 mL/kg), frusemide diuresis (1mg/kg) and urethral catheterisation if VUR was present. Final diagnosis was made using surgery (n = 15) or clinical outcome (n = 42). Clinical follow up exceeded one year and included repeat MAG3 scan (n = 20), resolving hydronephrosis on ultrasound (n = 15) or percutaneous antegrade pyelogram (n = 1). Initial scans were classified as obstructed (n 13), indeterminate (n = 13) or non obstructed (n = 30) based on standard qualitative and quantitative criteria. Using a normal range of >84%, OE correctly predicted 12/13 (92%) obstructed kidneys and 44/44 non-obstructed kidneys (100%). In the indeterminate group, three kidneys developed obstruction at follow -up and 10 became non obstructed. Initial OE predicted outcome in two and four kidneys respectively. Overall, OE sensitivity and specificity were 88% and 89%. In the subgroup of patients (n = 19) with reduced differential function (<40%) the sensitivity of OE was 100% and specificity was 75%. This compares to 83% and 66% for Tl/2 in this subgroup. Therefore OE is a useful marker of renal outflow tract obstruction and maybe superior to other parameters such as Tl/2 particularly when renal function is reduced. 1 tab.

  18. Tumors of the cardiac conduction system: are they an explanation for otherwise unexplained sudden cardiac death?

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    @@ Cardiac tumors are well described in the literature. The first reports of cardiac tumors date back hundreds of years.The prevalence of primary cardiac tumors at autopsy ranges from 0.001% to 0.3% with secondary tumors more common than in primary tumors.

  19. Cardiac Origins of the Postural Orthostatic Tachycardia Syndrome

    Science.gov (United States)

    Fu, Qi; VanGundy, Tiffany B.; Galbreath, M. Melyn; Shibata, Shigeki; Jain, Manish; Hastings, Jeffrey L.; Bhella, Paul S.; Levine, Benjamin D.

    2010-01-01

    Objectives To test the hypothesis that a small heart coupled with reduced blood volume contributes to the Postural Tachycardia Syndrome (POTS), while exercise training improves this syndrome. Background Patients with POTS have marked increases in heart rate during orthostasis. However, the underlying mechanisms are unknown and the effective therapy is uncertain. Methods Twenty-seven POTS patients underwent autonomic function tests, cardiac MRI, and blood volume measurements. Twenty-five of them participated in a 3-mo specially designed exercise training program with 19 completing the program; these patients were reevaluated after training. Results were compared with those of 16 healthy controls. Results Upright heart rate and total peripheral resistance were greater, while stroke volume and cardiac output were smaller in patients than controls. Baroreflex function was similar between groups. Left ventricular mass (median [25%, 75%], 1.26 [1.12, 1.37] vs 1.45 [1.34, 1.57] g/kg; PSeuss, the main character had a heart that was “two sizes too small.” PMID:20579544

  20. Atrophic cardiac remodeling induced by taurine deficiency in Wistar rats.

    Directory of Open Access Journals (Sweden)

    Mariele Castilho Pansani

    Full Text Available INTRODUCTION: Micronutrient deficiency is observed in heart failure patients. Taurine, for example, represents 50% of total free amino acids in the heart, and in vivo studies have linked taurine deficiency with cardiomyopathy. METHODS: Thirty-four male Wistar rats (body weight = 100 g were weighed and randomly assigned to one of two groups: Control (C or taurine-deficient (T (-. Beta-alanine at a concentration of 3% was added to the animals' water to induce taurine deficiency in the T (- group. On day 30, the rats were individually submitted to echocardiography; morphometrical and histopathological evaluation and metalloproteinase activity, oxidative stress and inflammation evaluation were performed. Tissue samples were collected to determine the taurine concentration in the heart. RESULTS: Taurine deficiency led to decreases in: ventricular wall thickness, left ventricle dry weight, myocyte sectional area, left ventricle posterior wall thickness and ventricular geometry. With regard to heart function, the velocity of the A wave, the ratio between the E and A wave, the ejection fraction, fractional shortening and cardiac output values were decreased in T (- rats, suggesting abnormal diastolic and systolic function. Increased fibrosis, inflammation and increased activation of metalloproteinases were not observed. Oxidative stress was increased in deficient animals. CONCLUSIONS: These data suggest that taurine deficiency promotes structural and functional cardiac alterations with unique characteristics.