Sample records for cardiac output values

  1. Reference values for total blood volume and cardiac output in humans

    Energy Technology Data Exchange (ETDEWEB)

    Williams, L.R. [Indiana Univ., South Bend, IN (United States). Division of Liberal Arts and Sciences

    1994-09-01

    Much research has been devoted to measurement of total blood volume (TBV) and cardiac output (CO) in humans but not enough effort has been devoted to collection and reduction of results for the purpose of deriving typical or {open_quotes}reference{close_quotes} values. Identification of normal values for TBV and CO is needed not only for clinical evaluations but also for the development of biokinetic models for ultra-short-lived radionuclides used in nuclear medicine (Leggett and Williams 1989). The purpose of this report is to offer reference values for TBV and CO, along with estimates of the associated uncertainties that arise from intra- and inter-subject variation, errors in measurement techniques, and other sources. Reference values are derived for basal supine CO and TBV in reference adult humans, and differences associated with age, sex, body size, body position, exercise, and other circumstances are discussed.

  2. Differences between directly measured and calculated values for cardiac output in the dogfish: a criticism of the Fick method.

    Science.gov (United States)

    Metcalfe, J D; Butler, P J

    1982-08-01

    Cardiac output has been measured directly, and calculated by the Fick method, during normoxia and hypoxia in six artificially perfused dogfish (Scyliorhinus canicula) in an attempt to estimate the accuracy of this method in fish. The construction and operation of a simple extra-corporeal cardiac bypass pump is described. This pump closely mimics the flow pulse profiles of the fish's own heart and allows complete control of both cardiac stroke volume and systolic and diastolic periods. During normoxia (PO2 = 21 kPa) there was no significant difference between directly measured and calculated values for cardiac output. However, some shunting of blood past the respiratory surface of the gills may have been obscured by cutaneous oxygen uptake. In response to hypoxia (PO2 = 8.6 kPa) there is either a decrease in the amount of blood being shunted past the respiratory surface of the gills and/or an increase in cutaneous oxygen uptake such that the Fick calculated value for cardiac output is on average 38% greater than the measured value. It is proposed that the increase in the levels of circulating catecholamines that is reported to occur in response to hypoxia in this species may play an important role in the observed response to hypoxia. The results are discussed in terms of their implications for the calculation of cardiac output by the Fick principle in fish.

  3. Low Cardiac Output Secondary to a Malpositioned Umbilical Venous Catheter: Value of Targeted Neonatal Echocardiography

    Directory of Open Access Journals (Sweden)

    Dany E. Weisz

    2014-05-01

    Full Text Available Systemic hypotension is common in very low birthweight preterm infants but the nature of the precipitating cause may be unclear. Targeted neonatal echocardiography (TnEcho is being increasingly used to support hemodynamic decisions in the neonatal intensive care unit (NICU, including identifying impairments in the transitional circulation of preterm infants, providing timely re-evaluation after institution of therapies and evaluating the placement of indwelling catheters. We present a case of a preterm infant with systemic hypotension and low cardiac output secondary to a large transatrial shunt induced by a malpositioned umbilical venous catheter. Repositioning of the line led to resolution of the hemodynamic disturbance and clinical instability, highlighting the utility of TnEcho in the NICU.

  4. Cardiac output during exercise

    DEFF Research Database (Denmark)

    Siebenmann, C; Rasmussen, P.; Sørensen, H.

    2015-01-01

    Several techniques assessing cardiac output (Q) during exercise are available. The extent to which the measurements obtained from each respective technique compares to one another, however, is unclear. We quantified Q simultaneously using four methods: the Fick method with blood obtained from...... the right atrium (Q(Fick-M)), Innocor (inert gas rebreathing; Q(Inn)), Physioflow (impedance cardiography; Q(Phys)), and Nexfin (pulse contour analysis; Q(Pulse)) in 12 male subjects during incremental cycling exercise to exhaustion in normoxia and hypoxia (FiO2  = 12%). While all four methods reported...... a progressive increase in Q with exercise intensity, the slopes of the Q/oxygen uptake (VO2) relationship differed by up to 50% between methods in both normoxia [4.9 ± 0.3, 3.9 ± 0.2, 6.0 ± 0.4, 4.8 ± 0.2 L/min per L/min (mean ± SE) for Q(Fick-M), Q(Inn), QP hys and Q(Pulse), respectively; P = 0...

  5. Cardiac output monitoring

    Directory of Open Access Journals (Sweden)

    Mathews Lailu

    2008-01-01

    Full Text Available Minimally invasive and non-invasive methods of estimation of cardiac output (CO were developed to overcome the limitations of invasive nature of pulmonary artery catheterization (PAC and direct Fick method used for the measurement of stroke volume (SV. The important minimally invasive techniques available are: oesophageal Doppler monitoring (ODM, the derivative Fick method (using partial carbon dioxide (CO 2 breathing, transpulmonary thermodilution, lithium indicator dilution, pulse contour and pulse power analysis. Impedance cardiography is probably the only non-invasive technique in true sense. It provides information about haemodynamic status without the risk, cost and skill associated with the other invasive or minimally invasive techniques. It is important to understand what is really being measured and what assumptions and calculations have been incorporated with respect to a monitoring device. Understanding the basic principles of the above techniques as well as their advantages and limitations may be useful. In addition, the clinical validation of new techniques is necessary to convince that these new tools provide reliable measurements. In this review the physics behind the working of ODM, partial CO 2 breathing, transpulmonary thermodilution and lithium dilution techniques are dealt with. The physical and the physiological aspects underlying the pulse contour and pulse power analyses, various pulse contour techniques, their development, advantages and limitations are also covered. The principle of thoracic bioimpedance along with computation of CO from changes in thoracic impedance is explained. The purpose of the review is to help us minimize the dogmatic nature of practice favouring one technique or the other.

  6. Methods and apparatus for determining cardiac output

    Science.gov (United States)

    Cohen, Richard J. (Inventor); Mukkamala, Ramakrishna (Inventor); Sherman, Derin A. (Inventor)

    2010-01-01

    The present invention provides methods and apparatus for determining a dynamical property of the systemic or pulmonary arterial tree using long time scale information, i.e., information obtained from measurements over time scales greater than a single cardiac cycle. In one aspect, the invention provides a method and apparatus for monitoring cardiac output (CO) from a single blood pressure signal measurement obtained at any site in the systemic or pulmonary arterial tree or from any related measurement including, for example, fingertip photoplethysmography.According to the method the time constant of the arterial tree, defined to be the product of the total peripheral resistance (TPR) and the nearly constant arterial compliance, is determined by analyzing the long time scale variations (greater than a single cardiac cycle) in any of these blood pressure signals. Then, according to Ohm's law, a value proportional to CO may be determined from the ratio of the blood pressure signal to the estimated time constant. The proportional CO values derived from this method may be calibrated to absolute CO, if desired, with a single, absolute measure of CO (e.g., thermodilution). The present invention may be applied to invasive radial arterial blood pressure or pulmonary arterial blood pressure signals which are routinely measured in intensive care units and surgical suites or to noninvasively measured peripheral arterial blood pressure signals or related noninvasively measured signals in order to facilitate the clinical monitoring of CO as well as TPR.

  7. William Harvey, Peter Lauremberg and cardiac output.

    Science.gov (United States)

    Teichmann, G

    1992-11-01

    In 1636, the Rostock professor of medicine and the art of poetry, Peter Lauremberg (1585-1639), was one of the earliest to mention circulation which had been discovered by William Harvey and documented in his anatomical manual. In 1628 William Harvey proved the existence of the blood circulation by calculating the "cardiac output in a half an hour (semihora)". The answer to the question why Harvey chose half an hour as the time range can be found in the way of measuring time usual at that period. The sandglasses were turned half-hourly in maritime navigation and the wheel-clocks on shore had only the hour-hand. Improved chronometry was one of the prerequisites for measuring cardiac output. The minute-hand became usual after 1700 and the second-hand later on. Taking into consideration the alterations of cardiac output made the latter one of the most important circulation parameters in diagnostics, prognostication and therapeutics.

  8. Comparison of cardiac output measurement techniques

    DEFF Research Database (Denmark)

    Espersen, K; Jensen, E W; Rosenborg, D;

    1995-01-01

    Simultaneously measured cardiac output obtained by thermodilution (TD), transcutaneous suprasternal ultrasonic Doppler (DOP), CO2-rebreathing (CR) and the direct Fick method (FI) were compared in eleven healthy subjects in a supine position (SU), a sitting position (SI), and during sitting exercise...... at a workload of 50 W (EX). The agreements between the techniques, two by two, were expressed as the bias calculated as the averaged differences between the techniques. Precision was expressed as the standard deviation of the bias. The overall agreement (bias +/- precision) between TD, DOP and CR respectively...... and CR, respectively, and TD were 2.5 +/- 2.2 and 2.6 +/- 1.6 l/min. The overall agreement between DOP and CR was 0.1 +/- 1.6 l/min. In conclusion, TD overestimated cardiac output compared to the other techniques and the poor agreement has to be taken into consideration especially in measures of low...

  9. A computerised dichromatic earpiece densitometer for the measurement of cardiac output.

    Science.gov (United States)

    Robinson, P S; Crowther, A; Jenkins, B S; Webb-Peploe, M M; Coltart, D J

    1979-07-01

    This study assesses a precalibrated dichromatic earpiece densitometer and microprocessor for the measurement of cardiac output by indocyanine green dye dilution. The measured cardiac output is compared with values of cardiac output simultaneously determined using a cuvette densitometer. The microprocessor computation of cardiac output agreed very closely with the cardiac output determined by manual calculation from the same dye dilution curves (standard deviation +/- 1.47%). The reproducibility of the earpiece densitometer (standard deviation +/- 5.2%) was virtually identical to that of the cuvette densitometer (+/- 5.3%). In a comparison of earpiece and cuvette densitometers for 60 measurements of cardiac output following pulmonary arterial injection of dye and for 50 measurements following femoral venous injection of dye, correlation coefficients were 0.83 and 0.78 and the standard deviations of the differences of simultaneous measurements were 7.2% and 8.3% respectively. The instrument offers an accurate reproducible and relatively noninvasive technique for measuring cardiac output.

  10. Newer methods of cardiac output monitoring

    Institute of Scientific and Technical Information of China (English)

    Yatin; Mehta; Dheeraj; Arora

    2014-01-01

    Cardiac output(CO) is the volume of blood ejected by each ventricle per minute and is the product of stroke volume and heart rate. CO can thus be manipulated by alteration in heart rate or rhythm, preload, contractility and afterload. Moreover it gives important information about tissue perfusion and oxygen delivery. CO can be measured by various methods and thermodilution method using pulmonary artery catheter(PAC) is till date considered as gold standard method. Complications associated with PAC led to development of newer methods which are minimally or non-invasive. Newer methods fulfil other properties like continuous and reproducible reading, cost effective, reliable during various physiological states and have fast response time. These methods are validated against the gold standard with good level agreement. In this review we have discussed various newer methods of CO monitoring and their effectiveness in clinical use.

  11. Measurement of cardiac output from dynamic pulmonary circulation time CT

    Energy Technology Data Exchange (ETDEWEB)

    Yee, Seonghwan, E-mail: Seonghwan.Yee@Beaumont.edu [Department of Radiation Oncology, Beaumont Health System, Royal Oak, Michigan 48073 (United States); Scalzetti, Ernest M. [Department of Radiology, SUNY Upstate Medical University, Syracuse, New York 13210 (United States)

    2014-06-15

    Purpose: To introduce a method of estimating cardiac output from the dynamic pulmonary circulation time CT that is primarily used to determine the optimal time window of CT pulmonary angiography (CTPA). Methods: Dynamic pulmonary circulation time CT series, acquired for eight patients, were retrospectively analyzed. The dynamic CT series was acquired, prior to the main CTPA, in cine mode (1 frame/s) for a single slice at the level of the main pulmonary artery covering the cross sections of ascending aorta (AA) and descending aorta (DA) during the infusion of iodinated contrast. The time series of contrast changes obtained for DA, which is the downstream of AA, was assumed to be related to the time series for AA by the convolution with a delay function. The delay time constant in the delay function, representing the average time interval between the cross sections of AA and DA, was determined by least square error fitting between the convoluted AA time series and the DA time series. The cardiac output was then calculated by dividing the volume of the aortic arch between the cross sections of AA and DA (estimated from the single slice CT image) by the average time interval, and multiplying the result by a correction factor. Results: The mean cardiac output value for the six patients was 5.11 (l/min) (with a standard deviation of 1.57 l/min), which is in good agreement with the literature value; the data for the other two patients were too noisy for processing. Conclusions: The dynamic single-slice pulmonary circulation time CT series also can be used to estimate cardiac output.

  12. Modelflow underestimates cardiac output in heat-stressed individuals

    DEFF Research Database (Denmark)

    Shibasaki, Manabu; Wilson, Thad E; Bundgaard-Nielsen, Morten

    2011-01-01

    An estimation of cardiac output can be obtained from arterial pressure waveforms using the Modelflow method. However, whether the assumptions associated with Modelflow calculations are accurate during whole body heating is unknown. This project tested the hypothesis that cardiac output obtained v...

  13. Peripheral vasodilatation determines cardiac output in exercising humans

    DEFF Research Database (Denmark)

    Bada, A A; Svendsen, J H; Secher, N H

    2012-01-01

    In dogs, manipulation of heart rate has no effect on the exercise-induced increase in cardiac output. Whether these findings apply to humans remain uncertain, because of the large differences in cardiovascular anatomy and regulation. To investigate the role of heart rate and peripheral...... arterial ATP infusion at rest. Exercise and ATP infusion increased cardiac output, leg blood flow and vascular conductance (P heart rate by up to 54 beats min(−1), cardiac output did not change in any of the three...... demonstrate that the elevated cardiac output during steady-state exercise is regulated by the increase in skeletal muscle blood flow and venous return to the heart, whereas the increase in heart rate appears to be secondary to the regulation of cardiac output....

  14. Validation of Fick cardiac output calculated with assumed oxygen consumption : a study of cardiac output during epoprostenol

    NARCIS (Netherlands)

    Bergstra, A; van den Heuvel, A F M; Zijlstra, F; Berger, R M F; Mook, G A; van Veldhuisen, D J

    2004-01-01

    OBJECTIVE: To test the validity of using assumed oxygen consumption for Fick cardiac output during administration of epoprostenol. METHODS: In 24 consecutive patients Fick cardiac output calculated with assumed oxygen consumption according to LaFarge and Miettinen (COLM) and according to Bergstra et

  15. Mini invasive hemodynamic monitoring: from arterial pressure to cardiac output

    OpenAIRE

    Della Rocca, Giorgio; Cecconi, Maurizio; Costa, Maria Gabriella

    2008-01-01

    To evaluate the Cardiac Output (CO) the standard invasive pulmonary artery catheter (PAC) is considered today the gold standard. The major criticism to the PAC is that its level of invasiveness is not supported by an improvement in patient's outcome. The interest to lesser and lesser invasive techniques is high. Therefore, the alternative techniques have been recently developed.Cardiac Output can be monitored continuously by different devices that analyze the arterial waveform to track change...

  16. Improvements in determination of cardiac output with a Swan-Ganz catheter.

    Science.gov (United States)

    Sakagami, M; Kuwana, K; Nakanishi, H; Sakai, K

    1990-01-01

    The time constant for heat transfer may affect exact determination of cardiac output with Swan-Ganz catheters. Commercially available Swan-Ganz catheters are provided with thermistors with varying time constants. Current monitoring of cardiac output is not corrected for these time constants, so the conventional method of determining cardiac output using the equation of Stewart-Hamilton produces marked errors. The authors propose a new method of determining cardiac output with Swan-Ganz catheters with varying time constants from thermal dilution curve data based on Newton's cooling law. Values for blood flow rate determined by the new method using a completely stirred tank of original design, mimicking the natural heart and using bovine blood, are almost the same as values observed at varying saline infusion volumes, saline temperatures, and saline infusion times.

  17. Reproducibility of cardiac power output and other cardiopulmonary exercise indices in patients with chronic heart failure.

    Science.gov (United States)

    Jakovljevic, Djordje G; Seferovic, Petar M; Nunan, David; Donovan, Gay; Trenell, Michael I; Grocott-Mason, Richard; Brodie, David A

    2012-02-01

    Cardiac power output is a direct measure of overall cardiac function that integrates both flow- and pressure-generating capacities of the heart. The present study assessed the reproducibility of cardiac power output and other more commonly reported cardiopulmonary exercise variables in patients with chronic heart failure. Metabolic, ventilatory and non-invasive (inert gas re-breathing) central haemodynamic measurements were undertaken at rest and near-maximal exercise of the modified Bruce protocol in 19 patients with stable chronic heart failure. The same procedure was repeated 7 days later to assess reproducibility. Cardiac power output was calculated as the product of cardiac output and mean arterial pressure. Resting central haemodynamic variables demonstrate low CV (coefficient of variation) (ranging from 3.4% for cardiac output and 5.6% for heart rate). The CV for resting metabolic and ventilatory measurements ranged from 8.2% for respiratory exchange ratio and 14.2% for absolute values of oxygen consumption. The CV of anaerobic threshold, peak oxygen consumption, carbon dioxide production and respiratory exchange ratio ranged from 3.8% (for anaerobic threshold) to 6.4% (for relative peak oxygen consumption), with minute ventilation having a CV of 11.1%. Near-maximal exercise cardiac power output and cardiac output had CVs of 4.1 and 2.2%, respectively. Cardiac power output demonstrates good reproducibility suggesting that there is no need for performing more than one cardiopulmonary exercise test. As a direct measure of cardiac function (dysfunction) and an excellent prognostic marker, it is strongly advised in the assessment of patients with chronic heart failure undergoing cardiopulmonary exercise testing.

  18. Continuous measurement of cardiac output using stochastic system identification techniques.

    Science.gov (United States)

    Yelderman, Mark

    2004-01-01

    Indicator dilutions techniques offer the most reliable methods of determining clinical cardiac output because of the elastic nature of the cardiac vessels. A catheter-mounted beating filament affords a simple means of supplying "heat" indicator, but is power and temperature limited because of possible patient injury. A stochastic signal processing method using pseudorandom binary infusion of heat offers a process of enhancing the signal to noise sufficiently to facilitate a computation of cardiac output over a reasonable time period (5 min) with a clinically acceptable error.

  19. Predictors of low cardiac output in decompensated severe heart failure

    Directory of Open Access Journals (Sweden)

    Marcelo Eidi Ochiai

    2011-01-01

    Full Text Available OBJECTIVE: To identify predictors of low cardiac output and mortality in decompensated heart failure. INTRODUCTION: Introduction: Patients with decompensated heart failure have a high mortality rate, especially those patients with low cardiac output. However, this clinical presentation is uncommon, and its management is controversial. METHODS: We studied a cohort of 452 patients hospitalized with decompensated heart failure with an ejection fraction of 60 years, and 64.6% were men. Low cardiac output was present in 281 (63% patients on admission. Chagas disease was the cause of heart failure in 92 (20.4% patients who had higher B type natriuretic peptide levels (1,978.38 vs. 1,697.64 pg/mL; P = 0.015. Predictors of low cardiac output were Chagas disease (RR: 3.655, P<0.001, lower ejection fraction (RR: 2.414, P<0.001, hyponatremia (RR: 1.618, P = 0.036, and renal dysfunction (RR: 1.916, P = 0.007. Elderly patients were inversely associated with low cardiac output (RR: 0.436, P = 0.001. Predictors of mortality were Chagas disease (RR: 2.286, P<0.001, ischemic etiology (RR: 1.449, P = 0.035, and low cardiac output (RR: 1.419, P = 0.047. CONCLUSIONS: In severe decompensated heart failure, predictors of low cardiac output are Chagas disease, lower ejection fraction, hyponatremia, and renal dysfunction. Additionally, Chagas disease patients have higher B type natriuretic peptide levels and a worse prognosis independent of lower ejection fraction.

  20. Volume and its relationship to cardiac output and venous return.

    Science.gov (United States)

    Magder, S

    2016-09-10

    Volume infusions are one of the commonest clinical interventions in critically ill patients yet the relationship of volume to cardiac output is not well understood. Blood volume has a stressed and unstressed component but only the stressed component determines flow. It is usually about 30 % of total volume. Stressed volume is relatively constant under steady state conditions. It creates an elastic recoil pressure that is an important factor in the generation of blood flow. The heart creates circulatory flow by lowering the right atrial pressure and allowing the recoil pressure in veins and venules to drain blood back to the heart. The heart then puts the volume back into the systemic circulation so that stroke return equals stroke volume. The heart cannot pump out more volume than comes back. Changes in cardiac output without changes in stressed volume occur because of changes in arterial and venous resistances which redistribute blood volume and change pressure gradients throughout the vasculature. Stressed volume also can be increased by decreasing vascular capacitance, which means recruiting unstressed volume into stressed volume. This is the equivalent of an auto-transfusion. It is worth noting that during exercise in normal young males, cardiac output can increase five-fold with only small changes in stressed blood volume. The mechanical characteristics of the cardiac chambers and the circulation thus ultimately determine the relationship between volume and cardiac output and are the subject of this review.

  1. Cardiac output estimation using pulmonary mechanics in mechanically ventilated patients

    Directory of Open Access Journals (Sweden)

    Hann Christopher E

    2010-11-01

    Full Text Available Abstract The application of positive end expiratory pressure (PEEP in mechanically ventilated (MV patients with acute respiratory distress syndrome (ARDS decreases cardiac output (CO. Accurate measurement of CO is highly invasive and is not ideal for all MV critically ill patients. However, the link between the PEEP used in MV, and CO provides an opportunity to assess CO via MV therapy and other existing measurements, creating a CO measure without further invasiveness. This paper examines combining models of diffusion resistance and lung mechanics, to help predict CO changes due to PEEP. The CO estimator uses an initial measurement of pulmonary shunt, and estimations of shunt changes due to PEEP to predict CO at different levels of PEEP. Inputs to the cardiac model are the PV loops from the ventilator, as well as the oxygen saturation values using known respiratory inspired oxygen content. The outputs are estimates of pulmonary shunt and CO changes due to changes in applied PEEP. Data from two published studies are used to assess and initially validate this model. The model shows the effect on oxygenation due to decreased CO and decreased shunt, resulting from increased PEEP. It concludes that there is a trade off on oxygenation parameters. More clinically importantly, the model also examines how the rate of CO drop with increased PEEP can be used as a method to determine optimal PEEP, which may be used to optimise MV therapy with respect to the gas exchange achieved, as well as accounting for the impact on the cardiovascular system and its management.

  2. Turbo decoding using two soft output values

    Institute of Scientific and Technical Information of China (English)

    李建平; 潘申富; 梁庆林

    2004-01-01

    It is well known that turbo decoding always begins from the first component decoder and supposes that the apriori information is "0" at the first iterative decoding. To alternatively start decoding at two component decoders, we can gain two soft output values for the received observation of an input bit. It is obvious that two soft output values comprise more sufficient extrinsic information than only one output value obtained in the conventional scheme since different start points of decoding result in different combinations of the a priori information and the input codewords with different symbol orders due to the permutation of an interleaver. Summarizing two soft output values for erery bit before making hard decisions, we can correct more errors due to their complement. Consequently, turbo codes can achieve better error correcting performance than before in this way. Simulation results show that the performance of turbo codes using the novel proposed decoding scheme can get a growing improvement with the increment of SNR in general compared to the conventional scheme. When the bit error probability is 10-5, the proposed scheme can achieve 0.5 dB asymptotic coding gain or so under the given simulation conditions.

  3. Pulse contour-derived cardiac output in hemodialysis patients

    DEFF Research Database (Denmark)

    Cordtz, Joakim; Ladefoged, Soeren D

    2010-01-01

    analysis, namely the Finometer monitor (FNM) for further use on patients dialyzing on a central vascular catheter. Fifty simultaneous cardiac output measurements were obtained during hemodialysis sessions in 25 patients. The internal variability of the FNM measurements was assessed by comparing 24 pairs...

  4. Pulse contour-derived cardiac output in hemodialysis patients

    DEFF Research Database (Denmark)

    Cordtz, Joakim; Ladefoged, Soeren D

    2010-01-01

    Reliable methods for cardiac output determination are essential for studying the pathophysiology of intradialytic hypotension. Use of the current gold standard, the Transonic monitor, requires an arteriovenous fistula. We wished to verify the accuracy of a method based on finger pulse contour...

  5. Evaluation of noninvasive cardiac output methods during exercise

    Science.gov (United States)

    Moore, Alan D.; Barrows, Linda H.; Rashid, Michael; Siconolfi, Steven F.

    1992-01-01

    Noninvasive techniques to estimate cardiac output (Qc) will be used during future space flight. This retrospective literature survey compared the Qc techniques of carbon dioxide rebreathing (CO2-R), CO2 single breath (CO2-S), Doppler (DOP), impedance (IM), and inert gas (IG: acetylene or nitrous oxide) to direct (DIR) assessments measured at rest and during exercise.

  6. Evaluation of transpulmonary thermodilution as a method to measure cardiac output in anesthetized cats.

    Science.gov (United States)

    Beaulieu, Kim E; Kerr, Carolyn L; McDonell, Wayne N

    2009-01-01

    The objectives of this study were to evaluate the use of a transpulmonary thermodilution (Trans) technique for the measurement of cardiac output, and to determine the agreement between Trans and conventional thermodilution (TD) in anesthetized cats. Using each technique, cardiac output was measured in 5 mature cats (weights 2.4 to 5.6 kg) anesthetized with isoflurane. To induce different levels of cardiac output in each cat, anesthesia was maintained at > 1.5x end-tidal minimum alveolar concentration (MAC) of isoflurane, and at 1.3x end-tidal isoflurane MAC with and without administration of dobutamine. At least 2 comparisons between TD and Trans values were made at each cardiac output rate. Thirty-two of the 42 recorded comparisons were analyzed. Linear regression analysis (TD vs Trans) yielded an r(2) value of 0.83. The mean bias (TD-Trans) was -3.7 mL/kg/min with limits of agreement of -35.9 to 28.5 mL/kg/min. The concordance coefficient was 0.91. The Trans method showed good relationship and good agreement with TD in anesthetized cats. The Trans method is a relatively noninvasive, practical, and safe method to measure cardiac output in anesthetized cats.

  7. Impedance cardiography for estimating cardiac output during submaximal and maximal work.

    Science.gov (United States)

    Kobayashi, Y; Andoh, Y; Fujinami, T; Nakayama, K; Takada, K; Takeuchi, T; Okamoto, M

    1978-09-01

    Impedance cardiography was used to estimate cardiac output in 10 men during rest and within 5 s after exercise on a bicycle ergometer, including work up to and including maximal aerobic capacity. An indwelling venous catheter permitted simultaneous sampling of venous blood for observing changes in hematocrit associated with each exercise level. Cardiac output, calculated from a standard equation which assumes a constant value of 150 omega.cm for the electrical resistivity of blood, was compared with corresponding calculations in which blood resistivity was individually determined as a function of hematocrit. It is concluded that many of the discrepancies in the literature related to values for cardiac output obtained during exercise by the impedance method may be inherent in calculations that do not consider the changing electrical resistivity of the blood with a changing hematocrit.

  8. Invasive and non-invasive methods for cardiac output measurement

    Directory of Open Access Journals (Sweden)

    Lavdaniti M.

    2008-01-01

    Full Text Available The hemodynamic status monitoring of high-risk surgical patients and critically ill patients inIntensive Care Units is one of the main objectives of their therapeutic management. Cardiac output is one of the mostimportant parameters for cardiac function monitoring, providing an estimate of whole body perfusion oxygen deliveryand allowing for an understanding of the causes of high blood pressure. The purpose of the present review is thedescription of cardiac output measurement methods as presented in the international literature. The articles documentthat there are many methods of monitoring the hemodynamic status of patients, both invasive and non-invasive, themost popular of which is thermodilution. The invasive methods are the Fick method and thermodilution, whereasthe non-invasive methods are oeshophaegeal Doppler, transoesophageal echocardiography, lithium dilution, pulsecontour, partial CO2 rebreathing and thoracic electrical bioimpedance. All of them have their advantages and disadvantages,but thermodilution is the golden standard for critical patients, although it does entail many risks. The idealsystem for cardiac output monitoring would be non-invasive, easy to use, reliable and compatible in patients. A numberof research studies have been carried out in clinical care settings, by nurses as well as other health professionals, for thepurpose of finding a method of measurement that would have the least disadvantages. Nevertheless, the thermodilutiontechnique remains the most common approach in use today.

  9. Validation of transpulmonary thermodilution cardiac output measurement in a pediatric animal model.

    NARCIS (Netherlands)

    Lemson, J.; Boode, W.P. de; Hopman, J.C.W.; Singh, S.K.; Hoeven, J.G. van der

    2008-01-01

    OBJECTIVE: This study was undertaken to validate the transpulmonary thermodilution cardiac output measurement (CO(TPTD)) in a controlled newborn animal model under various hemodynamic conditions with special emphasis on low cardiac output. DESIGN: Prospective, experimental, pediatric animal study. S

  10. Cardiac output and vasodilation in the vasovagal response

    DEFF Research Database (Denmark)

    Wieling, Wouter; Jardine, David L; de Lange, Frederik J

    2016-01-01

    with vagal-induced bradycardia in simple faint. Studies performed by Barcroft and Sharpey-Schafer between 1940 and 1950 used volume-based plethysmography to demonstrate major forearm vasodilation during extreme hypotension and concluded that the main mechanism for hypotension was vasodilation...... of CO using the Fick principle. They demonstrated that CO significantly fell before syncope, and little vasodilation occurred until very late in the vasovagal reaction Thus, since the 1970s, decreasing cardiac output rather than vasodilation has been regarded as the principal mechanism...

  11. Non-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing technique

    DEFF Research Database (Denmark)

    Gabrielsen, Anders; Videbaek, Regitze; Schou, Morten

    2002-01-01

    Values of effective pulmonary blood flow (Q(EP)) and cardiac output, determined by a non-invasive foreign gas rebreathing method (CO(RB)) using a new infrared photoacoustic gas analysing system, were compared with measurements of cardiac output obtained by the direct Fick (CO(FICK)) and thermodil......Values of effective pulmonary blood flow (Q(EP)) and cardiac output, determined by a non-invasive foreign gas rebreathing method (CO(RB)) using a new infrared photoacoustic gas analysing system, were compared with measurements of cardiac output obtained by the direct Fick (CO...... with significant shunt flow. In the eight patients without significant shunt flow, the agreement between Q(EP) and CO(FICK) was 0.3 +/- 0.9 litre x min(-1). In conclusion, a foreign gas rebreathing method with a new infrared photoacoustic gas analyser provided at least as reliable a measure of cardiac output...... as did thermodilution. In the absence of significant shunt flow, measurement of Q(EP) itself provides a reliable estimate of cardiac output in heart failure patients. The infrared photoacoustic gas analyser markedly facilitates clinical use of the rebreathing method in general, which makes the method...

  12. The decrease of cardiac chamber volumes and output during positive-pressure ventilation

    DEFF Research Database (Denmark)

    Kristensen, Kasper Kyhl; Ahtarovski, Kiril Aleksov; Iversen, Kasper

    2013-01-01

    the effect of PPV on the central circulation by studying cardiac chamber volumes with cardiac magnetic resonance imaging (CMR). We hypothesized that PPV lowers cardiac output (CO) mainly via the Frank-Starling relationship. In 18 healthy volunteers, cardiac chamber volumes and flow in aorta and the pulmonary...

  13. Cardiac fusion and complex congenital cardiac defects in thoracopagus twins: diagnostic value of cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of); Park, Jeong-Jun [University of Ulsan College of Medicine, Asan Medical Center, Department of Pediatric Cardiac Surgery, Seoul (Korea, Republic of); Kim, Ellen Ai-Rhan [University of Ulsan College of Medicine, Asan Medical Center, Division of Neonatology, Department of Pediatrics, Seoul (Korea, Republic of); Won, Hye-Sung [University of Ulsan College of Medicine, Asan Medical Center, Department of Obstetrics and Gynecology, Seoul (Korea, Republic of)

    2014-09-15

    Most thoracopagus twins present with cardiac fusion and associated congenital cardiac defects, and assessment of this anatomy is of critical importance in determining patient care and outcome. Cardiac CT with electrocardiographic triggering provides an accurate and quick morphological assessment of both intracardiac and extracardiac structures in newborns, making it the best imaging modality to assess thoracopagus twins during the neonatal period. In this case report, we highlight the diagnostic value of cardiac CT in thoracopagus twins with an interatrial channel and complex congenital cardiac defects. (orig.)

  14. The value of cardiac genetic testing.

    Science.gov (United States)

    Ingles, Jodie; Semsarian, Christopher

    2014-08-01

    Genetic testing is an important and necessary aspect of the management of families with cardiac genetic conditions. Commercial genetic tests are available for most cardiac genetic diseases, and increasing uptake amongst patients has contributed to a vastly improved knowledge of the genetic basis of these diseases. The incredible advances in genetic technologies have translated to faster, more comprehensive, and inexpensive commercial genetic tests and has completely changed the landscape of commercial genetic testing in recent years. While there are enormous challenges, mostly relating to interpretation of variants, the value of a genetic diagnosis should not be underestimated. In almost all cases, the single greatest utility is for the predictive genetic testing of family members. This review will describe the value of cardiac genetic testing in the current climate of rapid genetic advancements.

  15. ASSUMED OXYGEN-CONSUMPTION BASED ON CALCULATION FROM DYE DILUTION CARDIAC-OUTPUT - AN IMPROVED FORMULA

    NARCIS (Netherlands)

    BERGSTRA, A; VANDIJK, RB; HILLEGE, HL; LIE, KI; MOOK, GA

    1995-01-01

    This study was performed because of observed differences between dye dilution cardiac output and the Fick cardiac output, calculated from estimated oxygen consumption according to LaFarge and Miettinen, and to find a better formula for assumed oxygen consumption. In 250 patients who underwent left a

  16. Non-invasive cardiac output monitoring in neonates using bioreactance: a comparison with echocardiography.

    LENUS (Irish Health Repository)

    Weisz, Dany E

    2012-01-01

    Non-invasive cardiac output monitoring is a potentially useful clinical tool in the neonatal setting. Our aim was to evaluate a new method of non-invasive continuous cardiac output (CO) measurement (NICOM™) based on the principle of bioreactance in neonates.

  17. Kredsløbsmonitorering af kritisk syge patienter med "pulse contour cardiac output"-systemet

    DEFF Research Database (Denmark)

    Afshari, Arash; Perner, Anders; Bonde, Jan

    2006-01-01

    The Pulse Contour Cardiac Output (PiCCO) monitoring system measures cardiac output with high precision and accuracy. The system may replace the pulmonary artery catheter in most critically ill patients because the rate of serious complications may be lower. Whether the use of dynamic or static...

  18. Kredsløbsmonitorering med lithium dilution cardiac output-systemet

    DEFF Research Database (Denmark)

    Christiansen, Christian; Hostrup, Anette; Tønnesen, Else

    2008-01-01

    The lithium dilution cardiac output (LiDCO) system measures cardiac output beat-to-beat with high precision. The system is based on an arterial pulse power analysis which is calibrated every eight hours with a small non-pharmacological dose of lithium. The system is minimally invasive; it requires...

  19. Lack of agreement and trending ability of the endotracheal cardiac output monitor compared with thermodilution

    DEFF Research Database (Denmark)

    Møller-Sørensen, H; Hansen, K L; Ostergaard, M

    2012-01-01

    cardiac output (CO) during steady state and with induced haemodynamic changes in patients scheduled for elective cardiac surgery. METHODS: Twenty-five patients were enrolled. After induction of anaesthesia, endotracheal intubation using a dedicated ECOM tube, and insertion of the pulmonary artery catheter......BACKGROUND: Minimally invasive monitoring systems of central haemodynamics are gaining increasing popularity. The present study investigated the precision of the endotracheal cardiac output monitor (ECOM) system and its agreement with pulmonary artery catheter thermodilution (PAC TD) for measuring...

  20. Validation of the use of foreign gas rebreathing method for non-invasive determination of cardiac output in heart disease patients

    Institute of Scientific and Technical Information of China (English)

    DONG Liang; WANG Jian-an; JIANG Chen-yang

    2005-01-01

    Objective: To compare a new device (Innocor) for non-invasive measurement of cardiac output (CO) by foreign gas rebreathing method with conventional techniques used in the measurements of cardiac function. Methods: Cardiac outputs measured by Innocor (CORB) were compared with CO obtained by echocardiography (COEC), Swan-Ganz thermodilution (COTD),and left ventricle radiography (COLVR) in 34 patients subjected to cardiac catheterization. Values obtained from the four methods were analyzed by linear regression and paired values were compared by the method of Bland and Altman in SPSS. Results: There was strong positive correlation (r=0.94) between Innocor cardiac output values and the corresponding values obtained by thermodilution and between COEC and COLVR values. Thermodilution appears to overestimate cardiac output when compared to the values obtained with Innocor by (0.66±0.22) L/min (P<0.0001). There was no correlation between data obtained by Innocor and the corresponding COEC and COLVR values. Conclusion: Innocor CORB is an easy, safe and well established method for non-invasive measurement of cardiac output with good prospects for clinical application in heart disease patients.

  1. Measurement of cardiac output in adult and newborn animals by ascorbic acid dilution.

    Science.gov (United States)

    Smallwood, J K; Haselby, K A; Paradise, R R

    1984-05-01

    We have developed an ascorbic acid-dilution method for measuring cardiac output which requires minimal blood withdrawal. Ascorbate is injected into a central venous catheter. The indicator-dilution curve is obtained by drawing blood from an arterial catheter through an amperometric cell at 0.96 ml/min for 35 s. The current is measured by a picoammeter . A calibration curve is obtained in 15 s prior to each indicator-dilution curve. An on-line digital computer measures the curve areas and calculates the cardiac output. Cardiac outputs of heparinized dogs anesthetized with pentobarbital and halothane measured by this method (AA) compared closely to cardiac outputs measured by the dye-dilution method (CG) (AA = 0.96 CG + 20 ml/min, r = 0.98). Both the cardiac output and the arterial blood pressure remained stable during replicate measurements of the cardiac output of 1-day-old piglets. This system allows cardiac output determinations of neonatal subjects without excessive blood removal and, with further development, should be practical in human neonates.

  2. Cardiac output measurement : evaluation of methods in ICU patients

    NARCIS (Netherlands)

    Wilde, Robert Bernard Pieter de

    2009-01-01

    Accurate clinical assessment of the circulatory status is particular desirable in critically ill patients in the intensive care unit (ICU) and patients undergoing cardiac, thoracic, or vascular interventions. As the patient’s haemodynamic status may change rapidly, continuous monitoring of cardiac o

  3. Against Journal Articles for Measuring Value in University Output

    Science.gov (United States)

    Mbali, C.

    2010-01-01

    The following lines of arguments against the metrics of journal articles is developed: (1) Textual output should no longer be main valued output; (2) Digitalization enables other ways of advancing knowledge; (3) Measures by journal article favours the disciplines of Natural Science and Engineering (NSE) and moulds other disciplines of Social…

  4. Evaluation of cardiac output from a tidally ventilated homogeneous lung model.

    Science.gov (United States)

    Benallal, Habib; Beck, Kenneth C; Johnson, Bruce D; Busso, Thierry

    2005-10-01

    We used the direct Fick measurements to validate a method for estimating cardiac output by iteratively fitting VCO(2) at the mouth to lung model values. This model was run using a series of 50, 30 and 10 breaths to test sensitivity to number of breaths used for fitting. The lung was treated as a catenary two-compartment lung model consisting of a dead space compartment connected with a single alveolar space compartment, perfused with constant pulmonary blood flow. The implemented mathematical modeling described variations in O(2) and CO(2) compartmental fractions and alveolar volume. This model also included pulmonary capillary gas exchange. Experimental data were collected from measurements performed on six healthy subjects at rest and during 20, 40, 60 and 85-90% of peak V(O)(2). The correlation between the two methods was highest and the average agreement between the methods was best using 50 breaths R = 095; P model) = 1.1Q(Fick) - 2.3). The mean difference and lower to upper limits of agreement between measured and estimated data were 0.7 l/min (-2.7 to 4.1 l/min) for cardiac output; -0.9 ml/100 ml (-1.3 to -0.5 ml/100 ml) for arterial O(2) content; -0.8 ml/100 ml (-3.8 to 2.2 ml/100 ml) for mixed venous O(2) content and -0.1 ml/100 ml (-2.9 to 2.7 ml/100 ml) for arteriovenous difference O(2) content. The cardiac output estimated by the lung model was in good agreement with the direct Fick measurements in young healthy subjects.

  5. Comparison of cardiac output determined by bioimpedance and bioreactance methods at rest and during exercise.

    Science.gov (United States)

    Jakovljevic, Djordje G; Moore, Sarah; Hallsworth, Kate; Fattakhova, Gulnar; Thoma, Christian; Trenell, Michael I

    2012-04-01

    Bioreactance is a novel non-invasive method for cardiac output measurement that involves the analysis of blood flow-dependent changes in the phase shifts of electrical currents applied across the chest. The present study (1) compared resting and exercise cardiac outputs determined by bioreactance and bioimpedance methods and those estimated from measured oxygen consumption, (2) determined the relationship between cardiac output and oxygen consumption, and (3) assessed the agreement between the bioreactance and bioimpedance methods. Twelve healthy subjects (aged 30 ± 4 years) performed graded cardiopulmonary exercise test on a recumbent cycle ergometer on two occasions, 1 week apart. Cardiac output was monitored at rest, at 30, 50, 70, 90, 150 W and at peak exercise intensity by bioreactance and bioimpedance and expired gases collected. Resting cardiac output was not significantly different between the bioreactance and bioimpedance methods (6.2 ± 1.4 vs. 6.5 ± 1.4 l min(-1), P = 0.42). During exercise cardiac outputs were correlated with oxygen uptake for both bioreactance (r = 0.84, P bioimpedance techniques (r = 0.82, P bioimpedance estimated significantly lower cardiac outputs than both bioreactance and theoretically calculated cardiac output (14.3 ± 2.6 vs. 17.5 ± 5.2 vs. 16.9 ± 4.9 l min(-1), P bioimpedance method reported ~1.5 l min(-1) lower cardiac output than bioreactance with lower and upper limits of agreement of -2.98 to 5.98 l min(-1). Bioimpedance and bioreactance methods provide different cardiac output estimates, particularly at high exercise intensity, and therefore the two methods cannot be used interchangeably. In contrast with bioimpedance, bioreactance cardiac outputs are similar to those estimated from measured oxygen consumption.

  6. Application of bioreactance for cardiac output assessment during exercise in healthy individuals.

    Science.gov (United States)

    Elliott, Adrian; Hull, James H; Nunan, David; Jakovljevic, Djordje G; Brodie, David; Ansley, Lesley

    2010-07-01

    In patients with cardiac failure, bioreactance-based cardiac output (CO) monitoring provides a valid non-invasive method for assessing cardiac performance during exercise. The purpose of this study was to evaluate the efficacy of this technique during strenuous exercise in healthy, trained individuals. Fourteen recreational cyclists, mean (SD) age of 34 (8) years and relative peak oxygen uptake of (VO(2)) 56 (6) ml kg(-1) min(-1), underwent incremental maximal exercise testing, whilst CO was recorded continuously using a novel bioreactance-based device (CO(bio)). The CO(bio) was evaluated against relationship with VO(2), theoretical calculation of arterial-venous oxygen difference (C(a - v) O(2)) and level of agreement with an inert gas rebreathing method (CO(rb)) using a Bland-Altman plot. Bioreactance-based CO measurement was practical and straightforward in application, although there was intermittent loss of electrocardiograph signal at high-intensity exercise. At rest and during exercise, CO(bio) was strongly correlated with VO(2) (r = 0.84; P < 0.001), however, there was evidence of systematic bias with CO(bio) providing lower values than CO(rb); mean bias (limits of agreement) -19% (14.6 to -53%). Likewise, calculated (C(a - v) O(2)) was greater when determined using CO(bio) than CO(rb) (P < 0.001), although both devices provided values in excess of those reported in invasive studies. Bioreactance-based determination of CO provides a pragmatic approach to the continuous assessment of cardiac performance during strenuous exercise in trained individuals. Our findings, however, suggest that further work is needed to refine the key measurement determinants of CO using this device to improve measurement accuracy in this setting.

  7. Evaluation of a new arterial pressure-based cardiac output device requiring no external calibration

    Directory of Open Access Journals (Sweden)

    Amann Matthias

    2007-11-01

    Full Text Available Abstract Background Several techniques have been discussed as alternatives to the intermittent bolus thermodilution cardiac output (COPAC measurement by the pulmonary artery catheter (PAC. However, these techniques usually require a central venous line, an additional catheter, or a special calibration procedure. A new arterial pressure-based cardiac output (COAP device (FloTrac™, Vigileo™; Edwards Lifesciences, Irvine, CA, USA only requires access to the radial or femoral artery using a standard arterial catheter and does not need an external calibration. We validated this technique in critically ill patients in the intensive care unit (ICU using COPAC as the method of reference. Methods We studied 20 critically ill patients, aged 16 to 74 years (mean, 55.5 ± 18.8 years, who required both arterial and pulmonary artery pressure monitoring. COPAC measurements were performed at least every 4 hours and calculated as the average of 3 measurements, while COAP values were taken immediately at the end of bolus determinations. Accuracy of measurements was assessed by calculating the bias and limits of agreement using the method described by Bland and Altman. Results A total of 164 coupled measurements were obtained. Absolute values of COPAC ranged from 2.80 to 10.80 l/min (mean 5.93 ± 1.55 l/min. The bias and limits of agreement between COPAC and COAP for unequal numbers of replicates was 0.02 ± 2.92 l/min. The percentage error between COPAC and COAP was 49.3%. The bias between percentage changes in COPAC (ΔCOPAC and percentage changes in COAP (ΔCOAP for consecutive measurements was -0.70% ± 32.28%. COPAC and COAP showed a Pearson correlation coefficient of 0.58 (p PAC and ΔCOAP was 0.46 (p Conclusion Although the COAP algorithm shows a minimal bias with COPAC over a wide range of values in an inhomogeneous group of critically ill patients, the scattering of the data remains relative wide. Therefore, the used algorithm (V 1.03 failed to

  8. Value-Chain Networks and Entrepreneurial Output in Multinational Subsidiaries

    DEFF Research Database (Denmark)

    Dimitratos, Pavlos; Andersson, Ulf; Liouka, Ioanna

    2011-01-01

    on their entrepreneurial output. Entrepreneurial output can generate superior performance and positive externalities to the subsidiary. Based on a large-scale study of 268 multinational subsidiaries in the UK, we find that value-chain networks have a higher positive impact than multinational corporation (MNC) networks......Value-chain networks are of major importance to multinational subsidiaries, yet they have failed to receive significant attention in the literature. We extend the knowledge-based view of the firm by exploring whether three different types of multinational subsidiary networks have dissimilar impact...

  9. Cardiac output in exercise by impedance cardiography during breath holding and normal breathing.

    Science.gov (United States)

    Du Quesnay, M C; Stoute, G J; Hughson, R L

    1987-01-01

    Estimation of cardiac output by impedance cardiography (QZ) in exercise during normal breathing (NB) has been limited by motion artifact. Our objective was to obtain readable impedance cardiograms on five subjects during upright cycle exercise at 0, 50, 100, 150, and 200 W to permit comparisons of QZ during NB, expiratory breath hold (EXP) and inspiratory breath hold (INSP). Q was also determined using an equilibration CO2 rebreathing method [Q(RB)]. QZ during NB exceeded EXP QZ at 100, 150, and 200 W, and exceeded INSP QZ at 100 W (P less than 0.05). The low EXP QZ values were due to a significantly lower stroke volume at 100, 150, and 200 W (P less than 0.05). For the INSP QZ at 100 W, heart rate was lower than during EXP (P less than 0.05). Regression of QZ (NB) against Q(RB) resulted in a linear relationship (r = 0.93) over the range of Q = 7-26 1/min. The slope of the regression differed significantly from 1.0 (P less than 0.05). We conclude that QZ values obtained during EXP or INSP should not be assumed to represent QZ during NB, at least at work rates greater than 50 W. A consequence of the linear relationship between QZ(NB) and Q(RB) over the range of 0-200 W is that estimates of CO2 rebreathing cardiac output can be obtained by impedance cardiography if QZ is adjusted using an appropriate empirical factor.

  10. Pacing to treat low cardiac output syndrome following elective aortic valve replacement

    Directory of Open Access Journals (Sweden)

    Muhammad Ishaq

    2012-01-01

    Full Text Available We report a case of low cardiac output syndrome caused by dynamic left ventricular (LV outflow obstruction after aortic valve replacement (AVR. This recognized phenomenon probably occurs more frequently than appreciated, and the author suggests that this should be considered when managing patients with severe hemodynamic instability after AVR. In addition, we also focus on the fact that invasive pacemaker systems have significant effects on cardiac output augmentation postoperatively and in long-term management of patients with LV outflow tract (LVOT obstruction following AVR. The possible mechanisms and subsequent treatments are discussed.

  11. Comparison of an advanced minimally invasive cardiac output monitoring with a continuous invasive cardiac output monitoring during lung transplantation.

    Science.gov (United States)

    Tomasi, Roland; Prueckner, Stephan; Czerner, Stephan; Schramm, Renè; Preissler, Gerhard; Zwißler, Bernhard; von Dossow-Hanfstingl, Vera

    2016-08-01

    The aim of this study was to compare a continuous non-calibrated left heart cardiac index (CI) measurement by arterial waveform analysis (FloTrac(®)/Vigileo(®)) with a continuous calibrated right heart CI measurement by pulmonary artery thermodilution (CCOmbo-PAC(®)/Vigilance II(®)) for hemodynamic monitoring during lung transplantation. CI was measured simultaneously by both techniques in 13 consecutive lung transplants (n = 4 single-lung transplants, n = 9 sequential double-lung transplants) at distinct time points perioperatively. Linear regression analysis and Bland-Altman analysis with percentage error calculation were used for statistical comparison of CI measurements by both techniques. In this study the FloTrac(®) system underestimated the CI in comparison with the continuous pulmonary arterial thermodilution (p waveform and continuous pulmonary artery thermodilution are, therefore, not interchangeable during these complex operations.

  12. In vivo validation of cardiac output assessment in non-standard 3D echocardiographic images

    Science.gov (United States)

    Nillesen, M. M.; Lopata, R. G. P.; de Boode, W. P.; Gerrits, I. H.; Huisman, H. J.; Thijssen, J. M.; Kapusta, L.; de Korte, C. L.

    2009-04-01

    Automatic segmentation of the endocardial surface in three-dimensional (3D) echocardiographic images is an important tool to assess left ventricular (LV) geometry and cardiac output (CO). The presence of speckle noise as well as the nonisotropic characteristics of the myocardium impose strong demands on the segmentation algorithm. In the analysis of normal heart geometries of standardized (apical) views, it is advantageous to incorporate a priori knowledge about the shape and appearance of the heart. In contrast, when analyzing abnormal heart geometries, for example in children with congenital malformations, this a priori knowledge about the shape and anatomy of the LV might induce erroneous segmentation results. This study describes a fully automated segmentation method for the analysis of non-standard echocardiographic images, without making strong assumptions on the shape and appearance of the heart. The method was validated in vivo in a piglet model. Real-time 3D echocardiographic image sequences of five piglets were acquired in radiofrequency (rf) format. These ECG-gated full volume images were acquired intra-operatively in a non-standard view. Cardiac blood flow was measured simultaneously by an ultrasound transit time flow probe positioned around the common pulmonary artery. Three-dimensional adaptive filtering using the characteristics of speckle was performed on the demodulated rf data to reduce the influence of speckle noise and to optimize the distinction between blood and myocardium. A gradient-based 3D deformable simplex mesh was then used to segment the endocardial surface. A gradient and a speed force were included as external forces of the model. To balance data fitting and mesh regularity, one fixed set of weighting parameters of internal, gradient and speed forces was used for all data sets. End-diastolic and end-systolic volumes were computed from the segmented endocardial surface. The cardiac output derived from this automatic segmentation was

  13. In vivo validation of cardiac output assessment in non-standard 3D echocardiographic images

    Energy Technology Data Exchange (ETDEWEB)

    Nillesen, M M; Lopata, R G P; Gerrits, I H; Thijssen, J M; De Korte, C L [Clinical Physics Laboratory-833, Department of Pediatrics, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); De Boode, W P [Neonatology, Department of Pediatrics, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); Huisman, H J [Department of Radiology, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); Kapusta, L [Pediatric Cardiology, Department of Pediatrics, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands)], E-mail: m.m.nillesen@cukz.umcn.nl

    2009-04-07

    Automatic segmentation of the endocardial surface in three-dimensional (3D) echocardiographic images is an important tool to assess left ventricular (LV) geometry and cardiac output (CO). The presence of speckle noise as well as the nonisotropic characteristics of the myocardium impose strong demands on the segmentation algorithm. In the analysis of normal heart geometries of standardized (apical) views, it is advantageous to incorporate a priori knowledge about the shape and appearance of the heart. In contrast, when analyzing abnormal heart geometries, for example in children with congenital malformations, this a priori knowledge about the shape and anatomy of the LV might induce erroneous segmentation results. This study describes a fully automated segmentation method for the analysis of non-standard echocardiographic images, without making strong assumptions on the shape and appearance of the heart. The method was validated in vivo in a piglet model. Real-time 3D echocardiographic image sequences of five piglets were acquired in radiofrequency (rf) format. These ECG-gated full volume images were acquired intra-operatively in a non-standard view. Cardiac blood flow was measured simultaneously by an ultrasound transit time flow probe positioned around the common pulmonary artery. Three-dimensional adaptive filtering using the characteristics of speckle was performed on the demodulated rf data to reduce the influence of speckle noise and to optimize the distinction between blood and myocardium. A gradient-based 3D deformable simplex mesh was then used to segment the endocardial surface. A gradient and a speed force were included as external forces of the model. To balance data fitting and mesh regularity, one fixed set of weighting parameters of internal, gradient and speed forces was used for all data sets. End-diastolic and end-systolic volumes were computed from the segmented endocardial surface. The cardiac output derived from this automatic segmentation was

  14. A model to calculate cardiac output in hemodialysis patients by thermodilution

    Directory of Open Access Journals (Sweden)

    Alayoud Ahmed

    2012-06-01

    Full Text Available Abstract The Blood Temperature Monitor module (BTM is used to measure recirculation by thermodilution in dialysis. Numerous studies have confirmed its interest in the measuring of the vascular access flow. In this letter we describe a model to calculate cardiac output in dialysis by the BTM.

  15. Assessment of cardiac output with transpulmonary thermodilution during exercise in humans

    DEFF Research Database (Denmark)

    Calbet, José A L; Boushel, Robert

    2015-01-01

    The accuracy and reproducibility of transpulmonary thermodilution (TPTd) to assess cardiac output (Q̇) in exercising men was determined using indocyanine green (ICG) dilution as a reference method. TPTd has been utilized for the assessment of Q̇ and preload indexes of global end-diastolic volume...

  16. Effect of Hemorrhage on Cardiac Output, PVP, Alodosterone and Diuresis during Immersion in Men

    Science.gov (United States)

    Simanonok, K.; Greenleaf, John E.; Bernauer, E. M.; Wade, C. E.; Keil, L. C.

    1990-01-01

    The purpose of this study was to test the hypothesis that a reduction in blood volume would attenuate or eliminate immersion-induced increases in cardiac output (Q (sup dot) sub co)) and urine excretion, and to investigate accompanying vasoactive and fluid-electrolyte hormonal responses.

  17. IMPROVING AGREEMENT BETWEEN THORACIC BIOIMPEDANCE AND DYE DILUTION CARDIAC-OUTPUT ESTIMATION IN CHILDREN

    NARCIS (Netherlands)

    OCONNELL, AJ; TIBBALLS, J; COULTHARD, M

    1991-01-01

    The measurement of thoracic electrical bioimpedance (TEB) offers a continuous, non-invasive method for monitoring cardiac output (CO). For clinical use, agreement with a current standard should be demonstrated. We describe a modification to the manufacturer's suggested data entry into the NCCOM3-R6

  18. Phlebotomy eliminates the maximal cardiac output response to six weeks of exercise training

    DEFF Research Database (Denmark)

    Bonne, Thomas Christian; Doucende, Gregory; Flück, Daniela

    2014-01-01

    With this study we tested the hypothesis that six weeks of endurance training increases maximal cardiac output (Qmax) relatively more by elevating blood volume (BV) than by inducing structural and functional changes within the heart. Nine healthy but untrained volunteers (VO2max 47 ± 5 ml.min(-1)...

  19. Non-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing technique.

    Science.gov (United States)

    Gabrielsen, Anders; Videbaek, Regitze; Schou, Morten; Damgaard, Morten; Kastrup, Jens; Norsk, Peter

    2002-02-01

    Values of effective pulmonary blood flow (Q(EP)) and cardiac output, determined by a non-invasive foreign gas rebreathing method (CO(RB)) using a new infrared photoacoustic gas analysing system, were compared with measurements of cardiac output obtained by the direct Fick (CO(FICK)) and thermodilution (CO(TD)) methods in patients with heart failure or pulmonary hypertension. In 11 patients, of which three had shunt flow through areas without significant gas exchange, the mean difference (bias) and limits of agreement (+/- 2 S.D.) were 0.6 +/- 1.2 litre x min(-1) when comparing CO(FICK) and Q(EP), and -0.8 +/- 1.3 litre x min(-1) when comparing CO(FICK) and CO(TD). When correction for intrapulmonary shunt flow was applied (i.e. calculation of CO(RB)) in all 11 patients, the bias between CO(FICK) and CO(RB) was 0.1 +/- 0.9 litre x min(-1), primarily because agreement improved in the three patients with significant shunt flow. In the eight patients without significant shunt flow, the agreement between Q(EP) and CO(FICK) was 0.3 +/- 0.9 litre x min(-1). In conclusion, a foreign gas rebreathing method with a new infrared photoacoustic gas analyser provided at least as reliable a measure of cardiac output as did thermodilution. In the absence of significant shunt flow, measurement of Q(EP) itself provides a reliable estimate of cardiac output in heart failure patients. The infrared photoacoustic gas analyser markedly facilitates clinical use of the rebreathing method in general, which makes the method available to a larger group of clinicians working with patients with cardiovascular diseases.

  20. Application Value of the Ultrasound Cardiac Output Monitor in Hypovolemic Shock After Trauma%超声心输出量监测在创伤后低血容量休克中的应用价值

    Institute of Scientific and Technical Information of China (English)

    穆春凯; 王勇强

    2014-01-01

    目的:研究超声心输出量监测(USCOM)在创伤后低血容量休克患者液体复苏中的应用价值。方法回顾性分析46例创伤后低血容量休克患者的临床资料,根据治疗中是否应用USCOM分为常规组和USCOM组,对两组患者24 h乳酸水平≤2 mmol/L的比例、24小时液体平衡情况、并发症情况及病死率做一分析。结果经过积极的抢救治疗,两组患者24小时血乳酸≤2 mmol/L比例及病死率的差异无统计学意义,而USCOM组24小时复苏的液体量及发生肺水肿、MODS、DIC的比例较常规组明显减少。结论USCOM是一项准确、快速、安全、无创的血流动力学监测技术,能够有效的指导液体复苏,但仍存在一定的局限性。%Objective To research the application value of USCOM for patients with hypovolemic shock after trauma.MethodsThe clinical data of 46 patients with hypovolemic shock after trauma was analysised retrospectively. All patients were divided into USCOM group and routine group according to using USCOM or not. Then we compared the ratio of lactic acid≤2 mmol/L after 24 hours, transfusion quantities within 24 hours, the incidence of complications and mortality between the two groups. ResultsThere was statistically signiifcant difference of transfusion quantities within 24 hours and the incidence of complication (pulmonary edema、MODS、DIC) between the two groups after treatment,but the ratio of lactic acid≤2 mmol/L after 24 hours and the mortality were not signiifcantly different. Conclusions USCOM was accurate, rapid, safe and noninvasive, which can guide lfuid resuscitation effectively, but now there was still a certain degree of limitation.

  1. Cardiac output measurement by bioimpedance and noninvasive pulse contour analysis compared with the continuous pulmonary artery thermodilution technique

    NARCIS (Netherlands)

    Maass, Saskia W. M. C.; Roekaerts, Paul M. H. J.; Lance, Marcus D.

    2014-01-01

    Objective: The aim of the present study was to compare 2 noninvasive cardiac output measurement methods with the continuous cardiac output thermodilution (CCO-TD) method. Design: A single-center prospective design. Setting: A university hospital. Participants: Fifty-three consecutive patients schedu

  2. Peripartum cardiomyopathy: postpartum decompensation and use of non-invasive cardiac output monitoring.

    Science.gov (United States)

    Lorello, G; Cubillos, J; McDonald, M; Balki, M

    2014-02-01

    The utility of a non-invasive cardiac output monitor (NICOM™) in guiding the peripartum management and identification of postpartum complications in a patient with severe peripartum cardiomyopathy is reported. A 31-year-old nulliparous woman at 35 weeks of gestation presented with a three-week history of worsening dyspnea and progressive functional deterioration. A transthoracic echocardiogram showed severe left ventricular systolic dysfunction with an ejection fraction peripartum cardiomyopathy. We suggest that use of NICOM™ be extended into the postpartum period to detect signs of cardiac decompensation in such patients.

  3. Cardiac Output Measurements in Septic Patients: Comparing the Accuracy of USCOM to PiCCO

    Directory of Open Access Journals (Sweden)

    Sophia Horster

    2012-01-01

    Full Text Available USCOM is an ultrasound-based method which has been accepted for noninvasive hemodynamic monitoring in various clinical conditions (USCOM, Ultrasonic cardiac output monitoring. The present study aimed at comparing the accuracy of the USCOM device with that of the thermodilution technique in patients with septicemia. We conducted a prospective observational study in a medical but noncardiological ICU of a university hospital. Septic adult patients (median age 55 years, median SAPS-II-Score 43 points on mechanical ventilation and catecholamine support were monitored with USCOM and PiCCO (=70. Seventy paired left-sided CO measurements (transaortic access = COUS-A were obtained. The mean COUS-A were 6.55 l/min (±2.19 versus COPiCCO 6.5 l/min (±2.18. The correlation coefficient was =0.89. Comparison by Bland-Altman analysis revealed a bias of −0.36 l/min (±0.99 l/min leading to a mean percentage error of 29%. USCOM is a feasible and rapid method to evaluate CO in septic patients. USCOM does reliably represent CO values as compared to the reference technique based on thermodilution (PiCCO. It seems to be appropriate in situations where CO measurements are most pertinent to patient management.

  4. Continuous measurement of cardiac output with the use of stochastic system identification techniques.

    Science.gov (United States)

    Yelderman, M

    1990-10-01

    The limitations of developing a technique to measure cardiac output continuously are given. Logical explanations are provided for the economic, technical, and physiologic benefits of a stochastic system identification technique for measuring cardiac output. Heat is supplied by a catheter-mounted filament driven according to a pseudorandom binary sequence. Volumetric fluid flow is derived by a cross-correlation algorithm written in the C language. In vitro validation is performed with water in a flow bench. The computed flow (y) compared with the in-line-measured flow (x) yields the linear regression y = 1.024x - 0.157 (r = 0.99). The average coefficient of variation is less than 2% over a volumetric fluid flow range of 2 to 10 L/min.

  5. Estimating changes in cardiac output using an implanted hemodynamic monitor in heart failure patients

    DEFF Research Database (Denmark)

    Ståhlberg, Marcus; Damgaard, Morten; Ersgård, David;

    2010-01-01

    OBJECTIVES: The aim of this study was to evaluate an algorithm that estimates changes in cardiac output (CO) from right ventricular (RV) pressure waveforms derived from an implantable hemodynamic monitor (IHM) in heart failure patients. DESIGN: Twelve heart failure patients (NYHA II-III, EF 32......%) with an implantable hemodynamic monitor (Chronicle) were included in this study. Changes in cardiac output were provoked by body position change at rest (left lateral supine, horizontal supine, sitting, and standing) and a steady state bicycle exercise at 20 watts. Estimated CO derived from the IHM (CO...... was -0.39 L/min (11%). Limits of agreement were +/-1.56 L/min and relative error was 21%. CONCLUSIONS: A simple algorithm based on RV pressure wave form characteristics derived from an IHM can be used to estimate changes in CO in heart failure patients. These findings encourage further research aiming...

  6. Levosimendan in a neonate with severe coarctation of aorta and low cardiac output syndrome

    Directory of Open Access Journals (Sweden)

    Yann Olivier Boegli

    2013-01-01

    Full Text Available We report successful use of levosimendan after failed balloon angioplasty in a critically ill neonate with coarctation of aorta (CoA and severe low cardiac output syndrome (LCOS. Treatment with levosimendan improved left heart function, and decreased lactate and brain natriuretic peptide levels. To our knowledge, this is the first report on the safe and successful use of levosimendan in the management of LCOS due to severe CoA in a neonate awaiting surgical repair.

  7. Cardiac disturbances after pneumonectomy--the value of prophylactic digitalization.

    Science.gov (United States)

    Järvinen, A; Mattila, T; Appelqvist, P; Meurala, H; Mattila, S

    1978-01-01

    The incidence of postoperative cardiac disturbances and the value of prophylactic digitalization were studied retrospectively in 143 patients undergoing pneumonectomy for carcinoma of the lung. Cardiac arrhythmias occurred in 29% and tachycardia episodes in 30% of the patients. The incidence of myocardial infarction was 2%. Operative mortality was 4%. The cardiac disturbances developed more often after left than after right pneumonectomy. The age of the patients, a history of angina pectoris or hypertension did not markedly increase the incidence of cardiac disturbances, neither did operative factors, such as pericardiotomy, left atrial resection, major bleeding nor postoperative empyema. Prophylactic digitalization significantly reduced postoperative cardiac disorders, their frequency being 33% in the group of patients who received prophylactic digitalis compared with 65% in the group that did not.

  8. The effects of long-term aerobic exercise on cardiac structure, stroke volume of the left ventricle, and cardiac output.

    Science.gov (United States)

    Lee, Bo-Ae; Oh, Deuk-Ja

    2016-02-01

    The purpose of this study is to investigate the effect of the long-term aerobic exercises on cardiac structure, left ventricular stroke volume, and cardiac output. To achieve the purpose of the study, a total of 22 volunteers-including 10 people who have continued regular exercises and 12 people as the control group-were selected as subjects. With regard to data processing, the IBM SPSS Statistics ver. 21.0 was used to calculate the mean and standard deviation, and the difference of the means between the groups was verified through an independent t-test. As a result, there were significant differences between groups in the left ventricular end-diastolic internal dimension, left ventricular end-systolic internal dimension, left ventricular end-diastolic septum thickness. There were significant differences between groups in left ventricular end-diastolic volume, left ventricular mass, and left ventricular mass index per body surface area. However, in cardiac function, only left ventricular stroke volume showed a significant difference between groups.

  9. Multisite Tissue Oxygenation Monitoring Indicates Organ-Specific Flow Distribution and Oxygen Delivery Related to Low Cardiac Output in Preterm Infants With Clinical Sepsis

    NARCIS (Netherlands)

    van der Laan, Michelle E.; Roofthooft, Marcus T. R.; Fries, Marian W. A.; Schat, Trijntje E.; Bos, Arend F.; Berger, Rolf M. F.; Kooi, Elisabeth M. W.

    2016-01-01

    Objectives: Cardiac output may be compromised in preterm infants with sepsis. Whether low cardiac output is associated with low tissue oxygen supply in these patients is unclear. The aim of the current study was to assess the association between cardiac output, assessed by echocardiography, and tiss

  10. High flow variant postural orthostatic tachycardia syndrome amplifies the cardiac output response to exercise in adolescents.

    Science.gov (United States)

    Pianosi, Paolo T; Goodloe, Adele H; Soma, David; Parker, Ken O; Brands, Chad K; Fischer, Philip R

    2014-08-01

    Postural orthostatic tachycardia syndrome (POTS) is characterized by chronic fatigue and dizziness and affected individuals by definition have orthostatic intolerance and tachycardia. There is considerable overlap of symptoms in patients with POTS and chronic fatigue syndrome (CFS), prompting speculation that POTS is akin to a deconditioned state. We previously showed that adolescents with postural orthostatic tachycardia syndrome (POTS) have excessive heart rate (HR) during, and slower HR recovery after, exercise - hallmarks of deconditioning. We also noted exaggerated cardiac output during exercise which led us to hypothesize that tachycardia could be a manifestation of a high output state rather than a consequence of deconditioning. We audited records of adolescents presenting with long-standing history of any mix of fatigue, dizziness, nausea, who underwent both head-up tilt table test and maximal exercise testing with measurement of cardiac output at rest plus 2-3 levels of exercise, and determined the cardiac output () versus oxygen uptake () relationship. Subjects with chronic fatigue were diagnosed with POTS if their HR rose ≥40 beat·min(-1) with head-up tilt. Among 107 POTS patients the distribution of slopes for the , relationship was skewed toward higher slopes but showed two peaks with a split at ~7.0 L·min(-1) per L·min(-1), designated as normal (5.08 ± 1.17, N = 66) and hyperkinetic (8.99 ± 1.31, N = 41) subgroups. In contrast, cardiac output rose appropriately with in 141 patients with chronic fatigue but without POTS, exhibiting a normal distribution and an average slope of 6.10 ± 2.09 L·min(-1) per L·min(-1). Mean arterial blood pressure and pulse pressure from rest to exercise rose similarly in both groups. We conclude that 40% of POTS adolescents demonstrate a hyperkinetic circulation during exercise. We attribute this to failure of normal regional vasoconstriction during exercise, such that patients must increase flow through an

  11. Comparison of cardiac output determined by different rebreathing methods at rest and at peak exercise.

    Science.gov (United States)

    Jakovljevic, Djordje G; Nunan, David; Donovan, Gay; Hodges, Lynette D; Sandercock, Gavin R H; Brodie, David A

    2008-03-01

    Several rebreathing methods are available for cardiac output (Q (T)) measurement. The aims of this study were threefold: first, to compare values for resting Q (T) produced by the equilibrium-CO(2), exponential-CO(2) and inert gas-N(2)O rebreathing methods and, second, to evaluate the reproducibility of these three methods at rest. The third aim was to assess the agreement between estimates of peak exercise Q (T) derived from the exponential and inert gas rebreathing methods. A total of 18 healthy subjects visited the exercise laboratory on different days. Repeated measures of Q (T), measured in a seated position, were separated by a 5 min rest period. Twelve participants performed an incremental exercise test to determine peak oxygen consumption. Two more exercise tests were used to measure Q (T) at peak exercise using the exponential and inert gas rebreathing methods. The exponential method produced significantly higher estimates at rest (averaging 10.9 l min(-1)) compared with the equilibrium method (averaging 6.6 l min(-1)) and the inert gas rebreathing method (averaging 5.1 l min(-1); P < 0.01). All methods were highly reproducible with the exponential method having the largest coefficient of variation (5.3%). At peak exercise, there were non-significant differences between the exponential and inert gas rebreathing methods (P = 0.14). The limits of agreement were -0.49 to 0.79 l min(-1). Due to the ability to evaluate the degree of gas mixing and to estimate intra-pulmonary shunt, we believe that the inert gas rebreathing method has the potential to measure Q (T) more precisely than either of the CO(2) rebreathing methods used in this study. At peak exercise, the exponential and inert gas rebreathing methods both showed acceptable limits of agreement.

  12. Cardiac output assessment using oxygen consumption estimated from the left ventricular pressure-volume area.

    Science.gov (United States)

    Negroni, Jorge A; Lascano, Elena C; Bertolotti, Alejandro M; Gómez, Carmen B; Rodríguez Correa, Carlos A; Favaloro, Roberto R

    2010-01-01

    Use of a majority of structural variables (age, sex, height) to estimate oxygen consumption in the calculation of cardiac output (CO) by the Fick principle does not account for changes in physiological conditions. To improve this limitation, oxygen consumption was estimated based on the left ventricular pressure-volume area. A pilot study with 10 patients undergoing right cardiac catheterization showed that this approach was successful to estimate CO (r=0,73, vs. thermodilution measured CO). Further essays changing end-diastolic-volume in the pressure-volume area formula by body weight or body surface area showed that this last yielded the best correlation with the thermodilution measured CO (slope=1, ordinate =0.01 and r=0.93). These preliminary results indicate that use of a formula originated from the pressure-volume-area concept is a good alternative to estimate oxygen consumption for CO calculation.

  13. Non-Invasive Determination of Cardiac Output in Pre-Capillary Pulmonary Hypertension.

    Directory of Open Access Journals (Sweden)

    Frédéric Lador

    Full Text Available Cardiac output (CO is a major diagnostic and prognostic factor in pre-capillary pulmonary hypertension (PH. Reference methods for CO determination, like thermodilution (TD, require invasive procedures and allow only steady-state measurements. The Modelflow (MF method is an appealing technique for this purpose as it allows non-invasive and beat-by-beat determination of CO.We aimed to compare CO values obtained simultaneously from non-invasive pulse wave analysis by MF (COMF and by TD (COTD to determine its precision and accuracy in pre-capillary PH. The study was performed on 50 patients with pulmonary arterial hypertension (PAH or chronic thrombo-embolic PH (CTEPH. CO was determined at rest in all patients (n = 50 and during nitric oxide vasoreactivity test, fluid challenge or exercise (n = 48.Baseline COMF and COTD were 6.18 ± 1.95 and 5.46 ± 1.95 L·min-1, respectively. Accuracy and precision were 0.72 and 1.04 L·min-1, respectively. Limits of agreement (LoA ranged from -1.32 to 2.76 L·min-1. Percentage error (PE was ±35.7%. Overall sensitivity and specificity of COMF for directional change were 95.2% and 82.4%, (n = 48 and 93.3% and 100% for directional changes during exercise (n = 16, respectively. After application of a correction factor (1.17 ± 0.25, neither proportional nor fixed bias was found for subsequent CO determination (n = 48. Accuracy was -0.03 L·min-1 and precision 0.61 L·min-1. LoA ranged from -1.23 to 1.17 L·min-1 and PE was ±19.8%.After correction against a reference method, MF is precise and accurate enough to determine absolute values and beat-by-beat relative changes of CO in pre-capillary PH.

  14. Application of intraoperative arterial pressure-based cardiac output monitoring for patients undergoing coronary artery bypass grafting surgery

    Institute of Scientific and Technical Information of China (English)

    LU Jia-kai; ZHU Chen; JING He; WANG Yi-jun; QING En-ming

    2012-01-01

    Background For patients undergoing off-pump coronary artery bypass grafting (OPCABG),it is important to establish a hemodynamic monitoring system to obtain powerful parameters for better intraoperative treatment.This study aimed to observe the clinical feasibility of artedal pressure-based cardiac output (APCO) for cardiac output (CO) monitoring and to evaluate the correlation between APCO and pulmonary artery catheter (PAC) for CO measurement for patients undergoing OPCABG intraoperatively.Methods Fifty patients of Amedcan Society of Anaesthesiologists (ASA) classification Ⅱ-Ⅲ,undergoing elective OPCABG at Beijing Anzhen Hospital were randomly enrolled into this study.All patients were assigned to CO monitoring by PAC and APCO simultaneously.Patients with pacemaker,severe valvular heart disease,left ventdcular ejection fraction (EF) <40%,cardiac arrhythmias,peripheral vascular disease,application of intra-aortic balloon pump (IABP) and emergent diversion to cardiac pulmonary bypass were excluded.The radial artery wavaform was analyzed to estimate the stroke volume (SV) and heart rate (HR) continuously.CO was calculated as SV x HR; other derived parameters were cardiac index (CI),stroke volume index (SVI),systemic vascular resistance (SVR),and systemic vascular resistance index (SVRI).PAC was placed via right internal jugular vein and the correct position was confirmed by PAC waveforms.Continuous cardiac output (CCO),CI and other hemodynamic parameters were monitored at following 5 time points:immediate after anesthesia induction (baseline value),anastomosis of left intemal mammary artery to left anterior descending artery (LAD),anastomosis of left circumflex (LCX),anastomosis of posterior descending artery (PDA) and immediate after sternal closure.Results In the 50 patients,preoperative echocardiography measured left ventricular EF was (52.8±11.5)%,and 35 patients (70%) showed regional wall motion abnormalities.The correlation coefficient of CO

  15. NOTE: Increasing cardiac output and decreasing oxygenation sequence in pump twins of acardiac twin pregnancies

    Science.gov (United States)

    van Gemert, Martin J. C.; Umur, Asli; van den Wijngaard, Jeroen P. H. M.; Van Bavel, Ed; Vandenbussche, Frank P. H. A.; Nikkels, Peter G. J.

    2005-02-01

    An acardiac twin pregnancy is a rare but serious complication of monochorionic twinning and consists of an acardiac twin and a pump twin. The acardiac twin is a severely malformed fetus that lacks most organs, particularly a heart, but grows during pregnancy because it is perfused by the developmentally normal pump twin via a set of arterioarterial and venovenous placental anastomoses. Pump twins die intrauterine or neonatally in about 50% of the cases. Because the effects of an acardiac mass on the pump twin's development are incompletely known, methods for outcome prognosis are currently not available. We sought to derive simple relations for the pump twin's excess cardiac output and decreased oxygenation and to use available clinical cases for a preliminary test of the model. As a method, we used a theoretical flow model to represent the fetoplacental circulation of an acardiac twin pregnancy and estimated blood deoxygenation and reoxygenation following perfusion of the two bodies and placentas, respectively. The results show the pump twin's excess cardiac output and decrease of venous oxygen saturation to depend on the ratio of pump twin to acardiac twin umbilical blood flow, whose ratio can be measured by ultrasonography. The clinical cases show a decreasing umbilical flow ratio with gestation. In conclusion, prospective serial study is necessary to test whether measurement of umbilical flow ratios allows monitoring the pump twin's pathophysiologic development, possibly resulting in a guideline for prognosis of pump twin survival.

  16. Increasing cardiac output and decreasing oxygenation sequence in pump twins of acardiac twin pregnancies

    Energy Technology Data Exchange (ETDEWEB)

    Gemert, Martin J C van [Laser Center and Department of Obstetrics and Gynecology, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam (Netherlands); Umur, Asli [Laser Center and Department of Obstetrics and Gynecology, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam (Netherlands); Wijngaard, Jeroen P H M van den [Laser Center and Department of Obstetrics and Gynecology, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam (Netherlands); VanBavel, Ed [Department of Medical Physics, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands); Vandenbussche, Frank P H A [Department of Obstetrics, Leiden University Medical Center, Leiden (Netherlands); Nikkels, Peter G J [Department of Pathology, University Medical Center, Utrecht (Netherlands)

    2005-02-07

    An acardiac twin pregnancy is a rare but serious complication of monochorionic twinning and consists of an acardiac twin and a pump twin. The acardiac twin is a severely malformed fetus that lacks most organs, particularly a heart, but grows during pregnancy because it is perfused by the developmentally normal pump twin via a set of arterioarterial and venovenous placental anastomoses. Pump twins die intrauterine or neonatally in about 50% of the cases. Because the effects of an acardiac mass on the pump twin's development are incompletely known, methods for outcome prognosis are currently not available. We sought to derive simple relations for the pump twin's excess cardiac output and decreased oxygenation and to use available clinical cases for a preliminary test of the model. As a method, we used a theoretical flow model to represent the fetoplacental circulation of an acardiac twin pregnancy and estimated blood deoxygenation and reoxygenation following perfusion of the two bodies and placentas, respectively. The results show the pump twin's excess cardiac output and decrease of venous oxygen saturation to depend on the ratio of pump twin to acardiac twin umbilical blood flow, whose ratio can be measured by ultrasonography. The clinical cases show a decreasing umbilical flow ratio with gestation. In conclusion, prospective serial study is necessary to test whether measurement of umbilical flow ratios allows monitoring the pump twin's pathophysiologic development, possibly resulting in a guideline for prognosis of pump twin survival. (note)

  17. Cardiac output and vasodilation in the vasovagal response: An analysis of the classic papers.

    Science.gov (United States)

    Wieling, Wouter; Jardine, David L; de Lange, Frederik J; Brignole, Michele; Nielsen, Henning B; Stewart, Julian; Sutton, Richard

    2016-03-01

    The simple faint is secondary to hypotension and bradycardia resulting in transient loss of consciousness. According to Ohm's law applied to the circulation, BP = SVR × CO, hypotension can result from a decrease in systemic vascular resistance (SVR), cardiac output (CO), or both. It is important to understand that when blood pressure (BP) is falling, SVR and CO do not change reciprocally as they do in the steady state. In 1932, Lewis, assuming that decreased SVR alone accounted for hypotension, defined "the vasovagal response" along pathophysiologic lines to denote the association of vasodilation with vagal-induced bradycardia in simple faint. Studies performed by Barcroft and Sharpey-Schafer between 1940 and 1950 used volume-based plethysmography to demonstrate major forearm vasodilation during extreme hypotension and concluded that the main mechanism for hypotension was vasodilation. Plethysmographic measurements were intermittent and not frequent enough to capture rapid changes in blood flow during progressive hypotension. However, later investigations by Weissler, Murray, and Stevens performed between 1950 and 1970 used invasive beat-to-beat BP measurements and more frequent measurements of CO using the Fick principle. They demonstrated that CO significantly fell before syncope, and little vasodilation occurred until very late in the vasovagal reaction Thus, since the 1970s, decreasing cardiac output rather than vasodilation has been regarded as the principal mechanism for the hypotension of vasovagal syncope.

  18. A relative value method for measuring and evaluating cardiac reserve

    Directory of Open Access Journals (Sweden)

    Sun Xiaobo

    2002-12-01

    Full Text Available Abstract Background Although a very close relationship between the amplitude of the first heart sound (S1 and the cardiac contractility have been proven by previous studies, the absolute value of S1 can not be applied for evaluating cardiac contractility. However, we were able to devise some indicators with relative values for evaluating cardiac function. Methods Tests were carried out on a varied group of volunteers. Four indicators were devised: (1 the increase of the amplitude of the first heart sound after accomplishing different exercise workloads, with respect to the amplitude of the first heart sound (S1recorded at rest was defined as cardiac contractility change trend (CCCT. When the subjects completed the entire designed exercise workload (7000 J, the resulting CCCT was defined as CCCT(1; when only 1/4 of the designed exercise workload was completed, the result was defined as CCCT(1/4. (2 The ratio of S1 amplitude to S2 amplitude (S1/S2. (3 The ratio of S1 amplitude at tricuspid valve auscultation area to that at mitral auscultation area T1/M1 (4 the ratio of diastolic to systolic duration (D/S. Data were expressed as mean ± SD. Results CCCT(1/4 was 6.36 ± 3.01 (n = 67, CCCT(1 was 10.36 ± 4.2 (n = 33, S1/S2 was1.89 ± 0.94 (n = 140, T1/M1 was 1.44 ± 0.99 (n = 144, and D/S was 1.68 ± 0.27 (n = 172. Conclusions Using indicators CCCT(1/4 and CCCT(1 may be beneficial for evaluating cardiac contractility and cardiac reserve mobilization level, S1/S2 for considering the factor for hypotension, T1/M1 for evaluating the right heart load, and D/S for evaluating diastolic cardiac blood perfusion time.

  19. Noninvasive assessment of cardiac output from arterial pressure profiles during exercise.

    Science.gov (United States)

    Antonutto, G; Girardis, M; Tuniz, D; di Prampero, P E

    1995-01-01

    , MAPin, HR, PP, MAP are the above parameters at rest and during exercise, respectively. Also in this case, the coefficients f to 1 were determined by a computerized statistical method using Z* as the experimental reference. The values of Zcor so obtained allowed us to calculate SV from arterial pulse contour analysis as SVF = As.Z-1cor. The mean percentage error between the SVF obtained and the values simultaneously determined by PDE, was 10.0 (SD 8.7)%. It is concluded that the SV of the left ventricle, and hence cardiac output, can be determined during exercise from photoplethysmograph tracings with reasonable accuracy, provided that an initial estimate of SV at rest is made by means an independent high quality reference method.

  20. Left ventricular atrioventricular plane displacement is preserved with lifelong endurance training and is the main determinant of maximal cardiac output

    DEFF Research Database (Denmark)

    Steding-Ehrenborg, Katarina; Boushel, Robert C; Calbet, José A;

    2015-01-01

    BACKGROUND: Age-related decline in cardiac function can be prevented or postponed by lifelong endurance training. However, effects of normal ageing as well as of lifelong endurance exercise on longitudinal and radial contribution to stroke volume are unknown. The aim of this study was to determine...... resting longitudinal and radial pumping in elderly athletes, sedentary elderly and young sedentary subjects. Furthermore, we aimed to investigate determinants of maximal cardiac output in elderly. METHODS: 8 elderly athletes (63 ± 4 years), 7 elderly sedentary (66 ± 4 years) and 10 young sedentary...... subjects (29 ± 4 years) underwent cardiac MR. All subjects underwent maximal exercise testing and for elderly subjects maximal cardiac output during cycling was determined using dye dilution technique. RESULTS: Longitudinal and radial contribution to stroke volume did not differ between groups...

  1. Effect of heat stress on cardiac output and systemic vascular conductance during simulated hemorrhage to presyncope in young men

    DEFF Research Database (Denmark)

    Ganio, Matthew S; Overgaard, Morten; Seifert, Thomas;

    2012-01-01

    During moderate actual or simulated hemorrhage, as cardiac output decreases, reductions in systemic vascular conductance (SVC) maintain mean arterial pressure (MAP). Heat stress, however, compromises the control of MAP during simulated hemorrhage, and it remains unknown whether this response is due...... to a persistently high SVC and/or a low cardiac output. This study tested the hypothesis that an inadequate decrease in SVC is the primary contributing mechanism by which heat stress compromises blood pressure control during simulated hemorrhage. Simulated hemorrhage was imposed via lower body negative pressure...... (LBNP) to presyncope in 11 passively heat-stressed subjects (increase core temperature: 1.2 ± 0.2°C; means ± SD). Cardiac output was measured via thermodilution, and SVC was calculated while subjects were normothermic, heat stressed, and throughout subsequent LBNP. MAP was not changed by heat stress...

  2. Non-invasive measurements of cardiac output in atrial fibrillation: Inert gas rebreathing and impedance cardiography

    DEFF Research Database (Denmark)

    Osbak, Philip S; Henriksen, Jens Henrik Sahl; Kofoed, Klaus F;

    2011-01-01

    Abstract Background. Atrial fibrillation (AF) is associated with significant morbidity and mortality. To test the effect of interventions, knowledge of cardiac output (CO) is important. However, the irregular heart rate might cause some methods for determination of CO to have inherent weaknesses....... Objective. To assess the validity of these methods in AF, a new inert gas rebreathing device and impedance cardiography was tested with echocardiography as reference. Methods. Using a cross-sectional design, 127 patients with AF and 24 in SR were consecutively recruited. Resting CO was measured using inert...... gas rebreathing (n = 62) or impedance measurement of intrathoracic blood flow (n = 89) in separate studies with echocardiographic measurement as reference. Results. CO determined with impedance cardiography was mean 4.77 L/min ± 2.24(SD) compared to 4.93 L/min ± 1.17 by echocardiography (n = 89, n...

  3. Chronic measurement of cardiac output in unanesthetized rats using miniature thermocouples.

    Science.gov (United States)

    Osborn, J W; Barber, B J; Quillen, E W; Abram, R J; Cowley, A W

    1986-12-01

    A thermodilution technique is described for measuring steady-state cardiac output (CO) in conscious rats for periods of 2-3 wk. The method utilizes small implantable aortic thermocouples inserted via the femoral artery at the time of placement of other chronic indwelling catheters. Data are presented to validate the accuracy and reproducibility of the technique by acute in situ comparison with electromagnetic flowmeter measurements. Responses in chronically instrumented rats were tested with hemorrhage and infusions of vasodilator and vasoconstrictor agents administered repeatedly over a period of 9 days. The results show that the system is capable of measuring CO chronically and provides reproducible responses for periods of at least several weeks. We conclude that these methods provide a single, inexpensive, and accurate way to measure steady-state CO in conscious, unrestrained rats.

  4. Accuracy of Cardiac Output by Nine Different Pulse Contour Algorithms in Cardiac Surgery Patients: A Comparison with Transpulmonary Thermodilution

    Science.gov (United States)

    Bein, Berthold; Gruenewald, Matthias; Masing, Sarah; Huenges, Katharina; Haneya, Assad; Steinfath, Markus; Renner, Jochen

    2016-01-01

    Objective. Today, there exist several different pulse contour algorithms for calculation of cardiac output (CO). The aim of the present study was to compare the accuracy of nine different pulse contour algorithms with transpulmonary thermodilution before and after cardiopulmonary bypass (CPB). Methods. Thirty patients scheduled for elective coronary surgery were studied before and after CPB. A passive leg raising maneuver was also performed. Measurements included CO obtained by transpulmonary thermodilution (COTPTD) and by nine pulse contour algorithms (COX1–9). Calibration of pulse contour algorithms was performed by esophageal Doppler ultrasound after induction of anesthesia and 15 min after CPB. Correlations, Bland-Altman analysis, four-quadrant, and polar analysis were also calculated. Results. There was only a poor correlation between COTPTD and COX1–9 during passive leg raising and in the period before and after CPB. Percentage error exceeded the required 30% limit. Four-quadrant and polar analysis revealed poor trending ability for most algorithms before and after CPB. The Liljestrand-Zander algorithm revealed the best reliability. Conclusions. Estimation of CO by nine different pulse contour algorithms revealed poor accuracy compared with transpulmonary thermodilution. Furthermore, the less-invasive algorithms showed an insufficient capability for trending hemodynamic changes before and after CPB. The Liljestrand-Zander algorithm demonstrated the highest reliability. This trial is registered with NCT02438228 (ClinicalTrials.gov).

  5. Reference Values for Cardiac and Aortic Magnetic Resonance Imaging in Healthy, Young Caucasian Adults

    Science.gov (United States)

    Eikendal, Anouk L. M.; Bots, Michiel L.; Haaring, Cees; Saam, Tobias; van der Geest, Rob J.; Westenberg, Jos J. M.; den Ruijter, Hester M.; Hoefer, Imo E.; Leiner, Tim

    2016-01-01

    Background Reference values for morphological and functional parameters of the cardiovascular system in early life are relevant since they may help to identify young adults who fall outside the physiological range of arterial and cardiac ageing. This study provides age and sex specific reference values for aortic wall characteristics, cardiac function parameters and aortic pulse wave velocity (PWV) in a population-based sample of healthy, young adults using magnetic resonance (MR) imaging. Materials and Methods In 131 randomly selected healthy, young adults aged between 25 and 35 years (mean age 31.8 years, 63 men) of the general-population based Atherosclerosis-Monitoring-and-Biomarker-measurements-In-The-YOuNg (AMBITYON) study, descending thoracic aortic dimensions and wall thickness, thoracic aortic PWV and cardiac function parameters were measured using a 3.0T MR-system. Age and sex specific reference values were generated using dedicated software. Differences in reference values between two age groups (25–30 and 30–35 years) and both sexes were tested. Results Aortic diameters and areas were higher in the older age group (all p<0.007). Moreover, aortic dimensions, left ventricular mass, left and right ventricular volumes and cardiac output were lower in women than in men (all p<0.001). For mean and maximum aortic wall thickness, left and right ejection fraction and aortic PWV we did not observe a significant age or sex effect. Conclusion This study provides age and sex specific reference values for cardiovascular MR parameters in healthy, young Caucasian adults. These may aid in MR guided pre-clinical identification of young adults who fall outside the physiological range of arterial and cardiac ageing. PMID:27732640

  6. Rowing increases stroke volume and cardiac output to a greater extent than cycling.

    Science.gov (United States)

    Horn, P; Ostadal, P; Ostadal, B

    2015-01-01

    Exercise stimulates increases in heart rate (HR), stroke volume (SV) and cardiac output (CO). These adaptive mechanisms are strongly dependent on the type of exercise. Both rowing and cycling are widely used for physical training worldwide; however, evidence regarding the differences in major hemodynamic parameters during rowing and cycling remains insufficient. Ten healthy male volunteers were randomly assigned to perform either a rowing or cycling exercise. After 20 min rest, the group who had rowed first performed the cycling exercise and vice versa. Exercise was performed at a power-to-weight ratio of 2 W/kg for 2 min. HR, SV, CO and blood pressure (BP) were measured noninvasively using pulse-wave analysis at baseline and immediately after each exercise. HR, SV and CO were significantly higher after exercise than at rest. Whereas HR was comparable between rowing and cycling, SV and CO were significantly higher after rowing than after cycling. BP was comparable among all three measurements. Rowing increased SV and CO to a greater extent than cycling, whereas HR and BP were not influenced by the type of exercise. Our data suggest that rowing leads to more extensive stimulation of cardiac contractility and/or decreases in peripheral vascular resistance compared with cycling.

  7. Impact of pacing modality and biventricular pacing on cardiac output and coronary conduit flow in the post-cardiotomy patient.

    LENUS (Irish Health Repository)

    Healy, David G

    2012-02-03

    We have previously demonstrated the role of univentricular pacing modalities in influencing coronary conduit flow in the immediate post-operative period in the cardiac surgery patient. We wanted to determine the mechanism of this improved coronary conduit and, in addition, to explore the possible benefits with biventricular pacing. Sixteen patients undergoing first time elective coronary artery bypass grafting who required pacing following surgery were recruited. Comparison of cardiac output and coronary conduit flow was performed between VVI and DDD pacing with a single right ventricular lead and biventricular pacing lead placement. Cardiac output was measured using arterial pulse waveform analysis while conduit flow was measured using ultrasonic transit time methodology. Cardiac output was greatest with DDD pacing using right ventricular lead placement only [DDD-univentricular 5.42 l (0.7), DDD-biventricular 5.33 l (0.8), VVI-univentricular 4.71 l (0.8), VVI-biventricular 4.68 l (0.6)]. DDD-univentricular pacing was significantly better than VVI-univentricular (P=0.023) and VVI-biventricular pacing (P=0.001) but there was no significant advantage to DDD-biventricular pacing (P=0.45). In relation to coronary conduit flow, DDD pacing again had the highest flow [DDD-univentricular 55 ml\\/min (24), DDD-biventricular 52 ml\\/min (25), VVI-univentricular 47 ml\\/min (23), VVI-biventricular 50 ml\\/min (26)]. DDD-univentricular pacing was significantly better than VVI-univentricular (P=0.006) pacing but not significantly different to VVI-biventricular pacing (P=0.109) or DDD-biventricular pacing (P=0.171). Pacing with a DDD modality offers the optimal coronary conduit flow by maximising cardiac output. Biventricular lead placement offered no significant benefit to coronary conduit flow or cardiac output.

  8. Correlation between radius and respiration variation of inferior vena cava and hemodynamicmonitoring values of pulse-indicated continuous cardiac output(PiCCO)in septic shock pigs%脓毒症休克猪下腔静脉管径及呼吸变异指数与血流动力学的关系

    Institute of Scientific and Technical Information of China (English)

    王海峰; 刘笑雷; 陆海涛; 齐志伟; 闫圣涛; 顾承东; 张国强

    2012-01-01

    目的 探讨脓毒症休克时下腔静脉管径及呼吸变异指数与脉搏指示连续心排出量(PiCCO)血流动力学指标的关系.方法 取8只幼年猪,颈内静脉推注大肠杆菌内毒素(LPS,100tμg/kg)制作脓毒症休克模型,出模后予生理盐水进行液体复苏.分别在动物模型制作前、休克时、液体复苏1h及6h时点超声探测下腔静脉最大径(IVCmax)、最小径(IVCmin)并计算呼吸变异指数(IVCrvi),同时记录PiCCO血流动力学指标,包括:胸廓内血容量(ITBV)、全心舒张末容积(GEDV)、每搏输出量变异指数(SVV)和心脏指数(CI).采LSD-t检验比较液体复苏前后IVCmax、IVCmin、IVCrvi及PiCCO血流动力学指标的变化;采用Pearson相关性分析了解IVCmax、IVCmin及IVCrvi与PiCCO血流动力学指标的相关性.结果 液体复苏1 h IVCmax、IVC min、GEDV、ITBV及CI均显著大于休克时(P<0.01),SVV及IVCrvi均显著小于休克时(P<0.01);液体复苏6 h IVCmax、IWCmin、GEDV、ITBV及CI均显著大于休克时(P<0.01)及液体复苏1h(P<0.01),SVV及IVCrvi均显著小于休克时(P<0.01)及液体复苏1 h(P<0.01).IVCmax与SVV有相关性(P =0.024),与GEDV、ITBV及CI无相关性;IVCmin与SVV、GEDV、ITBV及CI均有相关性(分别P=0.009、P=0.003、P=0.001和P=0.015);IVCrvi与SVV、GEDV、ITBV及CI均有相关性(分别P=0.007、P<0.01、P<0.01和P<0.01).结论 下腔静脉管径及呼吸变异指数与PiCC0血流动力学指标具有相关性,可以为临床医师快速评估血容量提供依据.%Objective To explore the correlation between radius and respiratory variation of inferior vena cava(IVC)and hemodynamic monitoring values of pulse-indicated continuous cardiac output(PiCCO)in septic shock pigs.Methods A total of 8 pigs were used to establish animal model of septic shock by intravenous infusing LPS(100 μg/kg),and fluid resuscitation was followed with normal saline.Ultrasound was used to measure the maximum radius

  9. [Anesthesia management of geriatric patients with arterial pressure-based cardiac output monitoring FloTrac sensor for emergency surgery].

    Science.gov (United States)

    Yamamoto, Shunsuke; Goto, Koji; Yasuda, Norihisa; Kusaka, Junya; Hidaka, Seigo; Miyakawa, Hiroshi; Noguchi, Takayuki

    2009-06-01

    In cases of emergency surgery for geriatric patients, immediate anesthesia induction and careful intraoperative management is necessary without sufficient preoperative information. We report anesthesia management of a 96-year and a 90-year old patients with FloTrac sensor which is an arterial pressure-based cardiac output monitoring device and is able to manage critical patients effectively and safely during anesthesia.

  10. Influence of lung injury on cardiac output measurement using transpulmonary ultrasound dilution: a validation study in neonatal lambs

    NARCIS (Netherlands)

    Vrancken, S.L.A.G.; Boode, W.P. de; Hopman, J.C.W.; Looijen-Salamon, M.G.; Liem, K.D.; Heijst, A.F. van

    2012-01-01

    BACKGROUND: /st> Transpulmonary ultrasound dilution (TPUD) is a promising method for cardiac output (CO) measurement in severely ill neonates. The incidence of lung injury in this population is high, which might influence CO measurement using TPUD because of altered lung perfusion. We evaluated t

  11. Finger arterial versus intrabrachial pressure and continuous cardiac output during head-up tilt testing in healthy subjects

    NARCIS (Netherlands)

    Jellema, W.T.; Imholz, B.P.M.; Goudoever, J. van; Wesseling, K.H.; Lieshout, J.J. van

    1996-01-01

    1. The aims of this study were to determine the clinical feasibility of continuous, non-invasive Finapres recordings as a replacement for intrabrachial pressure during a 30 min head-up tilt, and the reliability of continuous cardiac output computation by pulse contour analysis from the finger arteri

  12. ADRB2 gly16gly Genotype, Cardiac Output, and Cerebral Oxygenation in Patients Undergoing Anesthesia for Abdominal Aortic Aneurysm Surgery

    DEFF Research Database (Denmark)

    Staalso, Jonatan Myrup; Rokamp, Kim Zillo; Olesen, Niels D.

    2016-01-01

    BACKGROUND: Gly16arg polymorphism of the adrenergic [beta]2-receptor is associated with the elevated cardiac output (Q) in healthy gly16-homozygotic subjects. We questioned whether this polymorphism also affects Q and regional cerebral oxygen saturation (SCO2) during anesthesia in vascular surgic...

  13. Acoustic output of multi-line transmit beamforming for fast cardiac imaging: a simulation study.

    Science.gov (United States)

    Santos, Pedro; Tong, Ling; Ortega, Alejandra; Løvstakken, Lasse; Samset, Eigil; D'hooge, Jan

    2015-07-01

    Achieving higher frame rates in cardiac ultrasound could unveil short-lived myocardial events and lead to new insights on cardiac function. Multi-line transmit (MLT) beamforming (i.e., simultaneously transmitting multiple focused beams) is a potential approach to achieve this. However, two challenges come with it: first, it leads to cross-talk between the MLT beams, appearing as imaging artifacts, and second, it presents acoustic summation in the near field, where multiple MLT beams overlap. Although several studies have focused on the former, no studies have looked into the implications of the latter on acoustic safety. In this paper, the acoustic field of 4-MLT was simulated and compared with single-line transmit (SLT). The findings suggest that standard MLT does present potential concerns. Compared with SLT, it shows a 2-fold increase in mechanical index (MI) (from 1.0 to 2.3), a 6-fold increase in spatial-peak pulse-average intensity (I(sppa)) (from 99 to 576 W∙cm(-2)) and a 12-fold increase in spatial-peak temporalaverage intensity (I(spta)) (from 119 to 1407 mW∙cm(-2)). Subsequently, modifications of the transmit pulse and delay line of MLT were studied. These modifications allowed for a change in the spatio-temporal distribution of the acoustic output, thereby significantly decreasing the safety indices (MI = 1.2, I(sppa) = 92 W∙cm(-2) and I(spta) = 366 mW∙cm(-2)). Accordingly, they help mitigate the concerns around MLT, reducing potential tradeoffs between acoustic safety and image quality.

  14. Early predictors of acute kidney injury in patients with cirrhosis and bacterial infection: urinary neutrophil gelatinase-associated lipocalin and cardiac output as reliable tools

    Science.gov (United States)

    Ximenes, Rafael O.; Farias, Alberto Q.; Helou, Claudia M.B.

    2015-01-01

    Background Hemodynamic abnormalities and acute kidney injury (AKI) are often present in infected cirrhotic patients. Hence, an early diagnosis of AKI is necessary, which might require the validation of new predictors as the determinations of urinary neutrophil gelatinase-associated lipocalin (uNGAL) and cardiac output. Methods We evaluated 18 infected cirrhotic patients subdivided into two groups at admission (0 hours). In Group I, we collected urine samples at 0 hours, 6 hours, 24 hours, and 48 hours for uNGAL and fractional excretion of sodium determinations. In Group II, we measured cardiac output using echocardiography. Results The age of patients was 55.0±1.9 years, and 11 patients were males. The Model for End-Stage Liver Disease score was 21±1, whereas the Child–Pugh score was C in 11 patients and B in 7 patients. Both patients in Group I and Group II showed similar baseline characteristics. In Group I, we diagnosed AKI in 5 of 9 patients, and the mean time to this diagnosis by measuring serum creatinine was 5.4 days. Patients with AKI showed higher uNGAL levels than those without AKI from 6 hours to 48 hours. The best accuracy using the cutoff values of 68 ng uNGAL/mg creatinine was achieved at 48 hours when we distinguished patients with and without AKI in all cases. In Group II, we diagnosed AKI in 4 of 9 patients, and cardiac output was significantly higher in patients who developed AKI at 0 hours. Conclusion Both uNGAL and cardiac output determinations allow the prediction of AKI in infected cirrhotic patients earlier than increments in serum creatinine. PMID:26484038

  15. Effects of water immersion on cardiac output of lean and fat male subjects at rest and during exercise.

    Science.gov (United States)

    Haffor, A S; Mohler, J G; Harrison, A C

    1991-02-01

    To investigate the combined effect of water immersion (WI) and lean body mass on cardiac output (Q), 12 healthy young men, 6 lean (fat less than 9%) and 6 fat (fat greater than 18%), were studied at rest and during steady state exercise approximating 30-40% Vo2 max under three experimental conditions. There were on land at 24 degrees C (LND), and immersed in water at 33-34 degrees C to hip level (HIP), and to the xiphoid (XIP). Metabolic measures were determined during 30-s periods from the average breath measurements. Mixed venous PCO2 (PVCO2) was estimated using rebreathing equilibration technique. Cardiac output was calculated by the indirect Fick's principle. In the lean individuals the average Q rose from a resting value of 5.43 +/- 0.43 (LND) to an exercise value of 7.25 +/- 0.40 L/min (XIP), and from resting value of 5.62 +/- 0.40 to an exercise 6.47 +/- 0.5 L/min in the fat individuals. During exercise, the associated increase in Q with increasing WI was significantly (p less than 0.05) higher compared with the land experiments. Inspection of the mean profile corresponding to this increase indicated that an increase in the level of immersion results in a significant (p less than 0.05) increase in the average Q for the lean group. For the fat group, the average Q was significantly (p less than 0.05) larger only at XIP level. At rest, heart rate dropped from 67 +/- 3.36 (LND) to 60 +/- 4.13 (XIP), and from 79 +/- 3.73 to 73 +/- 4.10 BPM for the lean and fat group, respectively. MANOVA analysis showed a significant (p less than 0.05) interaction between WI and group membership, indicating that the effect of WI is significantly different between the two groups. These data indicate that the change in central blood volume with WI depends, in part, on the lean mass of the body.

  16. Left ventricular atrioventricular plane displacement is preserved with lifelong endurance training and is the main determinant of maximal cardiac output.

    Science.gov (United States)

    Steding-Ehrenborg, Katarina; Boushel, Robert C; Calbet, José A; Åkeson, Per; Mortensen, Stefan P

    2015-12-01

    Age-related decline in cardiac function can be prevented or postponed by lifelong endurance training. However, effects of normal ageing as well as of lifelong endurance exercise on longitudinal and radial contribution to stroke volume are unknown. The aim of this study was to determine resting longitudinal and radial pumping in elderly athletes, sedentary elderly and young sedentary subjects. Furthermore, we aimed to investigate determinants of maximal cardiac output in elderly. Eight elderly athletes (63 ± 4 years), seven elderly sedentary (66 ± 4 years) and ten young sedentary subjects (29 ± 4 years) underwent cardiac magnetic resonance imaging. All subjects underwent maximal exercise testing and for elderly subjects maximal cardiac output during cycling was determined using a dye dilution technique. Longitudinal and radial contribution to stroke volume did not differ between groups (longitudinal left ventricle (LV) 52-65%, P = 0.12, right ventricle (RV) 77-87%, P = 0.16, radial 7.9-8.6%, P = 1.0). Left ventricular atrioventricular plane displacement (LVAVPD) was higher in elderly athletes and young sedentary compared with elderly sedentary subjects (14 ± 3, 15 ± 2 and 11 ± 1 mm, respectively, P cardiac output (R(2) = 0.61, P Longitudinal and radial contributions to stroke volume did not differ between groups. However, how longitudinal pumping was achieved differed; elderly athletes and young sedentary subjects showed similar AVPD whereas this was significantly lower in elderly sedentary subjects. Elderly sedentary subjects achieved longitudinal pumping through increased short-axis area of the ventricle. Large AVPD was a determinant of maximal cardiac output and exercise capacity.

  17. Cardiac output method comparison studies: the relation of the precision of agreement and the precision of method.

    Science.gov (United States)

    Hapfelmeier, Alexander; Cecconi, Maurizio; Saugel, Bernd

    2016-04-01

    Cardiac output (CO) plays a crucial role in the hemodynamic management of critically ill patients treated in the intensive care unit and in surgical patients undergoing major surgery. In the field of cardiovascular dynamics, innovative techniques for CO determination are increasingly available. Therefore, the number of studies comparing these techniques with a reference, such as pulmonary artery thermodilution, is rapidly growing. There are mainly two outcomes of such method comparison studies: (1) the accuracy of agreement and (2) the precision of agreement. The precision of agreement depends on the precision of each method, i.e., the precision that the studied and the reference technique are able to achieve. We call this "precision of method". A decomposition of variance shows that method agreement does not only depend on the precision of method but also on another important source of variability, i.e., the method's general variability about the true values. Ignorance of that fact leads to falsified conclusions about the precision of method of the studied technique. In CO studies, serial measurements are frequently confused with repeated measurements. But as the actual CO of a subject changes from assessment to assessment, there is no real repetition of a measurement. This situation equals a scenario in which single measurements are given for multiple true values per subject. In such a case it is not possible to assess the precision of method.

  18. A computational model-based validation of Guyton's analysis of cardiac output and venous return curves

    Science.gov (United States)

    Mukkamala, R.; Cohen, R. J.; Mark, R. G.

    2002-01-01

    Guyton developed a popular approach for understanding the factors responsible for cardiac output (CO) regulation in which 1) the heart-lung unit and systemic circulation are independently characterized via CO and venous return (VR) curves, and 2) average CO and right atrial pressure (RAP) of the intact circulation are predicted by graphically intersecting the curves. However, this approach is virtually impossible to verify experimentally. We theoretically evaluated the approach with respect to a nonlinear, computational model of the pulsatile heart and circulation. We developed two sets of open circulation models to generate CO and VR curves, differing by the manner in which average RAP was varied. One set applied constant RAPs, while the other set applied pulsatile RAPs. Accurate prediction of intact, average CO and RAP was achieved only by intersecting the CO and VR curves generated with pulsatile RAPs because of the pulsatility and nonlinearity (e.g., systemic venous collapse) of the intact model. The CO and VR curves generated with pulsatile RAPs were also practically independent. This theoretical study therefore supports the validity of Guyton's graphical analysis.

  19. Kinetics of Cardiac Output at the Onset of Exercise in Precapillary Pulmonary Hypertension

    Science.gov (United States)

    Bengueddache, Samir; Ferretti, Guido; Soccal, Paola M.; Noble, Stéphane; Beghetti, Maurice; Chemla, Denis; Hervé, Philippe; Sitbon, Olivier

    2016-01-01

    Purpose. Cardiac output (CO) is a cornerstone parameter in precapillary pulmonary hypertension (PH). The Modelflow (MF) method offers a reliable noninvasive determination of its beat-by-beat changes. So MF allows exploration of CO adjustment with the best temporal resolution. Methods. Fifteen subjects (5 PH patients, 10 healthy controls) performed a submaximal supine exercise on a cycle ergometer after 5 min of rest. CO was continuously determined by MF (COMF). Kinetics of heart rate (HR), stroke volume (SV), and CO were determined with 3 monoexponential models. Results. In PH patients, we observed a sudden and transitory drop of SV upon exercise onset. This implied a transitory drop of CO whose adjustment to a new steady state depended on HR increase. The kinetics of HR and CO for PH patients was slower than that of controls for all models and for SV in model 1. SV kinetics was faster for PH patients in models 2 and 3. Conclusion. This is the first description of beat-by-beat cardiovascular adjustments upon exercise onset in PH. The kinetics of HR and CO appeared slower than those of healthy controls and there was a transitory drop of CO upon exercise onset in PH due to a sudden drop of SV. PMID:27990432

  20. Kinetics of Cardiac Output at the Onset of Exercise in Precapillary Pulmonary Hypertension

    Directory of Open Access Journals (Sweden)

    Frédéric Lador

    2016-01-01

    Full Text Available Purpose. Cardiac output (CO is a cornerstone parameter in precapillary pulmonary hypertension (PH. The Modelflow (MF method offers a reliable noninvasive determination of its beat-by-beat changes. So MF allows exploration of CO adjustment with the best temporal resolution. Methods. Fifteen subjects (5 PH patients, 10 healthy controls performed a submaximal supine exercise on a cycle ergometer after 5 min of rest. CO was continuously determined by MF (COMF. Kinetics of heart rate (HR, stroke volume (SV, and CO were determined with 3 monoexponential models. Results. In PH patients, we observed a sudden and transitory drop of SV upon exercise onset. This implied a transitory drop of CO whose adjustment to a new steady state depended on HR increase. The kinetics of HR and CO for PH patients was slower than that of controls for all models and for SV in model 1. SV kinetics was faster for PH patients in models 2 and 3. Conclusion. This is the first description of beat-by-beat cardiovascular adjustments upon exercise onset in PH. The kinetics of HR and CO appeared slower than those of healthy controls and there was a transitory drop of CO upon exercise onset in PH due to a sudden drop of SV.

  1. Cardiac output and associated left ventricular hypertrophy in pediatric chronic kidney disease.

    Science.gov (United States)

    Weaver, Donald J; Kimball, Thomas R; Koury, Phillip R; Mitsnefes, Mark M

    2009-03-01

    A significant number of children with chronic kidney disease (CKD) have eccentric left ventricular hypertrophy (LVH), suggesting the role of preload overload. Therefore, we hypothesized that increased cardiac output (CO) might be a contributing factor for increased left ventricular mass index (LVMI) in these children. Patients aged 6-20 years with CKD stages 2-4 were enrolled. Echocardiograms were performed to assess LV function and geometry at rest and during exercise. Heart rate, stroke volume, and CO were also assessed at rest and during exercise. Twenty-four-hour ambulatory blood pressure (AMBP) monitoring was performed. Of the patients enrolled in this study, 17% had LVH. Increased stroke volume and CO were observed in patients with LVH compared to patients without LVH. Univariate analysis revealed significant positive associations between LVMI and CO, stroke volume, body mass index, pulse pressure from mean 24-h AMBP, and mean 24-h systolic BP load. No association with heart rate, age, parathyroid hormone, glomerular filtration rate, or anemia was observed. Only CO (beta = 1.98, p = 0.0005) was independently associated with increased LVMI in multivariate modeling (model R (2) = 0.25). The results of this study suggest that increased CO might predispose to increased LVMI in pediatric patients with CKD. Adaptations may be required to meet increased metabolic demand in these patients.

  2. High Output Cardiac Failure Resolving after Repair of AV Fistula in a Six-Month-Old

    Directory of Open Access Journals (Sweden)

    Uygar Teomete

    2016-01-01

    Full Text Available Background. Acquired AVF in pediatrics are commonly caused by iatrogenic means, including arterial or venous punctures. These fistulae can cause great hemodynamic stress on the heart as soon as they are created. Case. A six-month-old 25-week gestation infant was referred for respiratory distress. Initial exam revealed tachypnea, tachycardia, and hypertension. There was a bruit noted on her left arm. An ultrasound showed an arteriovenous fistula. Its location, however, precluded intervention because of the high risk for limb-loss. An echocardiogram showed evidence of pulmonary hypertension that was treated with sildenafil and furosemide. However, no improvement was seen. On temporary manual occlusion of the fistula, the patient was noted to have increased her blood pressure and decreased her heart rate, suggesting significant hemodynamic effect of the fistula. The fistula was subsequently ligated and the patient clinically and echocardiographically improved. Conclusion. A patient in high output cardiac failure or pulmonary artery hypertension, especially prematüre patients with preexisting lung disease, should be probed for history of multiple punctures, trauma, or surgery and should have prompt evaluation for AVF. If it can be diagnosed and repaired, most of the cases have been shown to decrease the stress on the heart and reverse the pathologic hemodynamics.

  3. High Output Cardiac Failure Resolving after Repair of AV Fistula in a Six-Month-Old

    Science.gov (United States)

    Teomete, Uygar; Gugol, Rubee Anne; Neville, Holly; Dandin, Ozgur; Young, Ming-Lon

    2016-01-01

    Background. Acquired AVF in pediatrics are commonly caused by iatrogenic means, including arterial or venous punctures. These fistulae can cause great hemodynamic stress on the heart as soon as they are created. Case. A six-month-old 25-week gestation infant was referred for respiratory distress. Initial exam revealed tachypnea, tachycardia, and hypertension. There was a bruit noted on her left arm. An ultrasound showed an arteriovenous fistula. Its location, however, precluded intervention because of the high risk for limb-loss. An echocardiogram showed evidence of pulmonary hypertension that was treated with sildenafil and furosemide. However, no improvement was seen. On temporary manual occlusion of the fistula, the patient was noted to have increased her blood pressure and decreased her heart rate, suggesting significant hemodynamic effect of the fistula. The fistula was subsequently ligated and the patient clinically and echocardiographically improved. Conclusion. A patient in high output cardiac failure or pulmonary artery hypertension, especially prematüre patients with preexisting lung disease, should be probed for history of multiple punctures, trauma, or surgery and should have prompt evaluation for AVF. If it can be diagnosed and repaired, most of the cases have been shown to decrease the stress on the heart and reverse the pathologic hemodynamics. PMID:26885434

  4. High Output Cardiac Failure Resolving after Repair of AV Fistula in a Six-Month-Old.

    Science.gov (United States)

    Teomete, Uygar; Gugol, Rubee Anne; Neville, Holly; Dandin, Ozgur; Young, Ming-Lon

    2016-01-01

    Background. Acquired AVF in pediatrics are commonly caused by iatrogenic means, including arterial or venous punctures. These fistulae can cause great hemodynamic stress on the heart as soon as they are created. Case. A six-month-old 25-week gestation infant was referred for respiratory distress. Initial exam revealed tachypnea, tachycardia, and hypertension. There was a bruit noted on her left arm. An ultrasound showed an arteriovenous fistula. Its location, however, precluded intervention because of the high risk for limb-loss. An echocardiogram showed evidence of pulmonary hypertension that was treated with sildenafil and furosemide. However, no improvement was seen. On temporary manual occlusion of the fistula, the patient was noted to have increased her blood pressure and decreased her heart rate, suggesting significant hemodynamic effect of the fistula. The fistula was subsequently ligated and the patient clinically and echocardiographically improved. Conclusion. A patient in high output cardiac failure or pulmonary artery hypertension, especially prematüre patients with preexisting lung disease, should be probed for history of multiple punctures, trauma, or surgery and should have prompt evaluation for AVF. If it can be diagnosed and repaired, most of the cases have been shown to decrease the stress on the heart and reverse the pathologic hemodynamics.

  5. Estimation of cardiac output and peripheral resistance using square-wave-approximated aortic flow signal

    Directory of Open Access Journals (Sweden)

    Nima eFazeli

    2012-07-01

    Full Text Available This paper presents a model-based approach to estimation of cardiac output (CO and total peripheral resistance (TPR. In the proposed approach, the response of cardiovascular system (CVS, described by the windkessel model, is tuned to the measurements of systolic, diastolic and mean arterial blood pressures (BP so as to yield optimal individual- and time-specific system time constant that is used to estimate CO and TPR. Unique aspects of the proposed approach are that it approximates the aortic flow as a train of square waves, and that it also assumes pressure-dependent arterial compliance, as opposed to the traditional windkessel model in which aortic flow is approximated as a train of impulses and constant arterial compliance is assumed. It was shown that the proposed model encompasses the standard windkessel model as a limiting case, and that it also yields more realistic BP waveform response than the standard windkessel model. The proposed approach has potential to outperform its standard counterpart by treating systolic, diastolic and mean BP as independent features in estimating CO and TPR, rather than solely resorting to pulse pressure as in the case of the standard windkessel model. Experimental results from in-vivo data collected from a number of animal subjects supports the viability of the proposed approach in that it could achieve approximately 29% and 24% reduction in CO and TPR errors when compared with its standard counterpart.

  6. Resistance reconstructed estimation of total peripheral resistance from computationally derived cardiac output - biomed 2013.

    Science.gov (United States)

    Hill, Labarron K; Sollers Iii, John J; Thayer, Julian F

    2013-01-01

    Efficient functioning of the peripheral vasculature is an essential component in healthy cardiovascular regulation. Alterations in this functioning have been linked to the etiology and pathophysiological course of cardiovascular disease (CVD), especially hypertension. Given its significant role in the maintenance of both healthy and pathological blood pressure, total peripheral resistance (TPR), an index of the vasoconstrictive and elastic properties of the peripheral vasculature, has received much attention in this regard. However, obtaining a reliable estimate of TPR remains a complex and costly endeavor, primarily due to the necessity for sophisticated instrumentation as well as associated limitations in deriving cardiac output (CO). We have previously described a simple estimation method for CO using only arterial blood pressure and heart rate (Hill et al, 2012). In the present study we extend this technique to the estimation of TPR using beat-to-beat blood pressure data from the same sample of 67 young (mean age = 20.04± 2.8), healthy men (n = 30) and women (n = 37). Estimated TPR (TPRest) was calculated from the computationally-derived estimate of CO and mean arterial pressure (MAP). Correlation between TPR obtained via the validated Model-Flow technique and TPRest was moderate (r =.73, p <. 000) and stronger in men (r =.78, p <. 000) compared to women (r =.66, p <. 001). These data further suggest that reconstructed measures of hemodynamic functioning may be validly and adequately estimated from limited data sources.

  7. Dynamic vs. fixed bag filling: impact on cardiac output rebreathing protocol.

    Science.gov (United States)

    Zavorsky, Gerald S; Beck, Kenneth C; Cass, Lauren M; Artal, Raul; Wagner, Peter D

    2010-04-15

    The purpose of this study was to compare the repeatability (2.77 multiplied by the within-subject SD)between two different rebreathing protocols on cardiac output ( ˙Q ), pulmonary diffusing capacity for carbon monoxide (DLCO) and nitric oxide (DLNO), and pulmonary capillary blood volume (Vc). This study compared two bag volume protocols [Fixed Bag Volume (FBV) = bag volume fixed at 60% of forced vital capacity; Dynamic Bag Volume (DBV) = bag volume matched to tidal volume at each stage of exercise].Ten females (age = 27±8 yrs; ˙VO2, (peak)=2.5±0.6 L/min had measurements at rest (12%), 52%, 88%, and 100% of ˙VO2, (peak) on two study days. Neither the slope nor intercept of ˙Q vs. ˙VO2 were different between either bag volume protocols. The slope of DLCO vs. ˙Q was the same but the intercept was higher for the FBV protocol. The bag volume affected the slope and the intercept between DLNO vs. ˙Q (p DLNO (p ≤ 0.06). Measurement error was lower for Vc when using the FBV protocol (p = 0.02). Also, the pattern of bag volume used during rebreathing maneuvers affected the relation between DLNO vs. ˙Q more than it affected DLCO vs. ˙Q , or Vc vs. ˙Q. Additionally, the FBV protocol provided less measurement error for Vc compared to the DBV protocol [corrected].

  8. Low Cardiac Output Leads Hepatic Fibrosis in Right Heart Failure Model Rats.

    Directory of Open Access Journals (Sweden)

    Yoshitaka Fujimoto

    Full Text Available Hepatic fibrosis progresses with right heart failure, and becomes cardiac cirrhosis in a severe case. Although its causal factor still remains unclear. Here we evaluated the progression of hepatic fibrosis using a pulmonary artery banding (PAB-induced right heart failure model and investigated whether cardiac output (CO is responsible for the progression of hepatic fibrosis.Five-week-old Sprague-Dawley rats divided into the PAB and sham-operated control groups. After 4 weeks from operation, we measured CO by echocardiography, and hepatic fibrosis ratio by pathological examination using a color analyzer. In the PAB group, CO was significantly lower by 48% than that in the control group (78.2±27.6 and 150.1±31.2 ml/min, P<0.01. Hepatic fibrosis ratio and serum hyaluronic acid, an index of hepatic fibrosis, were significantly increased in the PAB group than those in the control group (7.8±1.7 and 1.0±0.2%, P<0.01, 76.2±27.5 and 32.7±7.5 ng/ml, P<0.01. Notably, the degree of hepatic fibrosis significantly correlated a decrease in CO. Immunohistological analysis revealed that hepatic stellate cells were markedly activated in hypoxic areas, and HIF-1α positive hepatic cells were increased in the PAB group. Furthermore, by real-time PCR analyses, transcripts of profibrotic and fibrotic factors (TGF-β1, CTGF, procollargen I, procollargen III, MMP 2, MMP 9, TIMP 1, TIMP 2 were significantly increased in the PAB group. In addition, western blot analyses revealed that the protein level of HIF-1α was significantly increased in the PAB group than that in the control group (2.31±0.84 and 1.0±0.18 arbitrary units, P<0.05.Our study demonstrated that low CO and tissue hypoxia were responsible for hepatic fibrosis in right failure heart model rats.

  9. Analysis of the Dynamic Relationship among Financial Fund for Agriculture, Agricultural Output Value and Farmers’ income

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    By using the methods of co-integration, impulse response function and variance decomposition, I conduct the empirical research on the dynamic relationship among China’s financial fund for agriculture, agricultural output value, and farmers’ income from the year 1978 to the year 2009. The results indicate that the government’s financial fund for agriculture plays the significant role in promoting agricultural output value and farmers’ income in the long run, but this role of promoting is not prominent in the short run; in the mean time, agricultural output value plays insignificant role in promoting farmers’ income and the government’s financial fund for agriculture; farmers’ income plays the significant role in promoting agricultural output value and the government’s financial fund for agriculture.

  10. Prognostic Value of Brain Diffusion Weighted Imaging After Cardiac Arrest

    Science.gov (United States)

    Wijman, Christine A.C.; Mlynash, Michael; Caulfield, Anna Finley; Hsia, Amie W.; Eyngorn, Irina; Bammer, Roland; Fischbein, Nancy; Albers, Gregory W.; Moseley, Michael

    2009-01-01

    Objective Outcome prediction is challenging in comatose post-cardiac arrest survivors. We assessed the feasibility and prognostic utility of brain diffusion-weighted MRI (DWI) during the first week. Methods Consecutive comatose post-cardiac arrest patients were prospectively enrolled. MRI data of patients who met predefined specific prognostic criteria were used to determine distinguishing ADC thresholds. Group 1: death at 6 months and absent motor response or absent pupillary reflexes or bilateral absent cortical responses at 72 hours, or vegetative at 1 month. Group 2A: Glasgow outcome scale (GOS) score of 4 or 5 at 6 months. Group 2B: GOS of 3 at 6 months. The percentage of voxels below different apparent diffusion coefficient (ADC) thresholds was calculated at 50 × 10−6 mm2/sec intervals. Results Overall, 86% of patients underwent MR imaging. Fifty-one patients with 62 brain MRIs were included in the analyses. Forty patients met the specific prognostic criteria. The percentage of brain volume with an ADC value below 650–700 × 10−6 mm2/sec best differentiated between group 1 and groups 2A and 2B combined (p<0.001), while the 400–450 × 10−6 mm2/sec threshold best differentiated between groups 2A and 2B (p=0.003). The ideal time window for prognostication using DWI was between 49 to 108 hours after the arrest. When comparing MRI in this time window with the 72 hour neurological examination MRI improved the sensitivity for predicting poor outcome by 38% while maintaining 100% specificity (p=0.021). Interpretation Quantitative DWI in comatose post-cardiac arrest survivors holds great promise as a prognostic adjunct. PMID:19399889

  11. [Echocardiographic evaluation of cardiac output in patients with acute myocardial infarction (author's transl)].

    Science.gov (United States)

    Nador, F; De Martini, M; Binda, A; Salmaso, G C; Radrizzani, D; Lotto, A

    1980-01-01

    Echocardiography is a non invasive technique particularly useful to assess both hemodynamics and left ventricular performances; different methods have been proposed to evaluate echocardiographically the cardiac output. The aim of this work is to suggest a new method (planimetry of the area enclosed by echoes from the mitral valve) stating its advantages and limits and to test three already known methods (cubes method, method of Lalani and Lee, method of Rasmussen and coll.) comparing them to thermodilution. In 24 patients admitted in our Coronary Care Unit for acute myocardial infarction 30 measurements have been performed simultaneously with echocardiography and thermodilution. Statistical analysis (correlation coefficient with the method of the square minimums and Student's 't') of the results has shown that the cubes method is unprecise (P = NS) and unbiased (d = 0.97 +/- 15.46); Lalani-Lee method is unprecise (P = NS) and biased (d = 9.64 +/- 21.36) by a systematic underestimate error concealed by the poor precision; Rasmussen and coll. method is precise (P < 0.01) but biased (d = --3.03 +/- 5.5), the systematic mistake being entirely due to the group of patients with abnormal hemodynamics. Our method is precise (P < 0.01) and unbiased (d = --0.04 +/- 9.62) in patients both with normal and abnormal hemodynamics. Therefore this method offers the following advantages: 1) it is unbiased, even in the presence of abnormal left ventricular performance; 2) it is sufficiently precise, having a correlation coefficient with thermodilution of r = 0.80; 3) it measures directly the amount of flow due to the atrial systole; 4) the measurement is rapid and hardly biased by the reader.

  12. Predictors of Post Pericardiotomy Low Cardiac Output Syndrome in Patients With Pericardial Effusion

    Directory of Open Access Journals (Sweden)

    Sabzi Feridoun

    2015-03-01

    Full Text Available Introduction: Pathological involvement of pericardium by any disease that resulting in effusion may require decompression and pericardiectomy. The current article describes rare patients with effusion who after pericadiectomy and transient hemodynamic improvement rapidly developed progressive heart failure and subsequent multi organ failure.Methods: During periods of five years, 423 patients in our hospital underwent pericardiotomy for decompression of effusion. The clinical characteristics of those patient with postoperative low cardiac output (B group (14 cases recorded and compared with other patients without this postoperative complication (A group by test and X2. Significant variables in invariables (P≤0.1 entered in logistic regression analysis and odd ratio of these significant variables obtained. Results: Idiopathic pericardial effusion, malignancy, renal failure, connective tissue disease, viral pericarditis was found in 125 patients (27%, 105 patients (25.4%, 65 patients (15.6%, 50 (17.1% and 10 (2.4% of patients subsequently. The factors that predict post-operative death in logistic regression analysis were malignancy, radiotherapy, constrictive pericarditis inotropic drug using IABP using, pre-operative EF and pericardial calcification.Conclusion: Certain preoperative variables such as malignancy, radiotherapy, low EF, calcified pericardium and connective tissue disease are associated with POLCOS and post-operative risk of death. This paradoxical response to pericardial decompression may be more frequent than currently appreciated. Its cause may relate to the sudden removal of the chronic external ventricular support from the effusion or thicken pericardium resulting in ventricular dilatation and failure or intra operative myocardial injury due to pericardiectomy of calcified pericardium, radiation and cardiomyopathy.

  13. Low cardiac output predicts development of hepatorenal syndrome and survival in patients with cirrhosis and ascites

    DEFF Research Database (Denmark)

    Krag, A; Bendtsen, F; Henriksen, J H;

    2010-01-01

    OBJECTIVES: Recent studies suggest that cardiac dysfunction precedes development of the hepatorenal syndrome. In this follow-up study, we aimed to investigate the relation between cardiac and renal function in patients with cirrhosis and ascites and the impact of cardiac systolic function...... on survival. Patients and DESIGN: Twenty-four patients with cirrhosis and ascites were included. Cardiac function was investigated by gated myocardial perfusion imaging (MPI) for assessment of cardiac index (CI) and cardiac volumes. The renal function was assessed by determination of glomerular filtration...... (130 (SD 46) vs 78 (SD 29) mumol/l, pdeveloped hepatorenal syndrome type 1 within 3 months was higher in the group with low CI than in the high CI group (43% vs 5%, p = 0.04). Patients with the lowest CI (N = 8) had significantly poorer survival at 3, 9, and 12 months...

  14. Clinical review: Guyton - the role of mean circulatory filling pressure and right atrial pressure in controlling cardiac output

    OpenAIRE

    William R Henderson; Griesdale, Donald EG; Walley, Keith R; Sheel, A. William

    2010-01-01

    Arthur Guyton's concepts of the determinative role of right heart filling in cardiac output continue to be controversial. This paper reviews his seminal experiments in detail and clarifies the often confusing concepts underpinning his model. One primary criticism of Guyton's model is that the parameters describing venous return had not been measured in a functioning cardiovascular system in humans. Thus, concerns have been expressed in regard to the ability of Guyton's simplistic model, with ...

  15. Combined use of phenoxybenzamine and dopamine for low cardiac output syndrome in children at withdrawal from cardiopulmonary bypass.

    OpenAIRE

    Kawamura, M.; Minamikawa, O; Yokochi, H; Maki, S.; Yasuda, T.; Mizukawa, Y

    1980-01-01

    The combined use of phenoxybenzamine and dopamine was applied in infants and children when it was difficult to come off cardiopulmonary bypass for low cardiac output. The rationale of this method is to prevent the alpha-adrenergic action of dopamine by phenoxybenzamine and to encourage the beta-adrenergic and direct specific action of dopamine. Dopamine was used in dosage of 10 to 30 micrograms/kg per min after the additional administration of a half of the initial dosage of phenoxybenzamine;...

  16. Signal processing technique for non-invasive real-time estimation of cardiac output by inductance cardiography (thoracocardiography).

    Science.gov (United States)

    Bucklar, G B; Kaplan, V; Bloch, K E

    2003-05-01

    Inductance cardiography (thoracocardiography) non-invasively monitors changes in stroke volume by recording ventricular volume curves with an inductive plethysmographic transducer encircling the chest at the level of the heart. Clinical application of this method has been hampered, as data analysis has not been feasible in real time. Therefore a novel, real-time signal processing technique for inductance cardiography has been developed. Its essential concept consists in performance of multiple tasks by several, logically linked signal processing modules that have access to common databases. Based on these principles, a software application was designed that performs acquisition, display, filtering and ECG-triggered ensemble averaging of inductance signals and separates cardiogenic waveforms from noise related to respiration and other sources. The resulting ventricular volume curves are automatically analysed. Performance of the technique for monitoring cardiac output in real time was compared with thermodilution in four patients in an intensive care unit. The bias (mean difference) among 76 paired thoracocardiographic and thermodilution derived changes in cardiac output was 0%; limits of agreement (+/- 2 SD of the bias) were +/- 25%. It is concluded that the proposed signal processing technique for inductance cardiography holds promise for non-invasive, real-time estimation of changes in cardiac output.

  17. Effect of hemorrhage on cardiac output, vasopressin, aldosterone, and diuresis during immersion in men

    Science.gov (United States)

    Greenleaf, J. E.; Simanonok, K.; Bernauer, E. M.; Wade, C. E.; Keil, L. C.

    1992-01-01

    The purpose of this research was to test the hypotesis that a reduction in blood volume would attenuate or eliminate immersion-induced increases in cardiac output (Q(sub co)) and urine excretion, and to investigate accompanying vasoactive and fluid-electrolyte hormonal responses. Eight men (19-23 yr) were supine during a 2-hr control period in air, and then sat for 5-hr test periods in air at 20 C (dry control, DC); water at 34.5 C (wet control, WC); and water (34.5 C) after hemorrhage (WH) of 14.8 plus or minus 0.3 percent of their blood volume. Blood volume was -11.6 plus or minus 0.6 percent at immersion (time 0). Mean (bar-X hrs 1-5) Q(sub co) was unchanged in WC (5.3 plus or minus 0.01 l/min) and in WH (4.5 plus or minus 0.1 l/min), but decreased (P less than 0.05) in DC to 3.6 plus or minus 0.1 l/min. Mean urine excretion rates were 1.0 plus or minus 0.2 ml/min for DC and 1.1 plus or minus 0.2 ml/min for WH; both were lower (P less than 0.05) than that for WC of 2.0 plus or minus 0.4 ml/min. Plasma (Na+) and (Osm) were unchanged in all experiments. Mean plasma vasopressin (PVP) (bar-X hrs 1-5) was 1.1 plus or minus 0.1 pg/ml in WC, and higher (P less than 0.05) in DC (2.1 plus or minus 0.2 pg/ml)and WH (2.1 plus or minus 0.1 pg/ml); it was unchanged during air and water test periods. Thus, hemorrhage attenuated the immersion-induced increase in Q(sub co), eliminated the WC diuresis, maintained plasma renin activity and PVP at DC levels and did not change immersion-induced aldosterone suppression; the osmotic diuresis during control immersion is apparently not due to either aldosterone suppression or vasopressin suppression.

  18. Femoral Blood Flow and Cardiac Output During Blood Flow Restricted Leg Press Exercise

    Science.gov (United States)

    Everett, M. E.; Hackney, K.; Ploutz-Snyder, L.

    2011-01-01

    Low load blood flow restricted resistance exercise (LBFR) causes muscle hypertrophy that may be stimulated by the local ischemic environment created by the cuff pressure. However, local blood flow (BF) during such exercise is not well understood. PURPOSE: To characterize femoral artery BF and cardiac output (CO) during leg press exercise (LP) performed at a high load (HL) and low load (LL) with different levels of cuff pressure. METHODS: Eleven subjects (men/women 4/7, age 31.4+/-12.8 y, weight 68.9+/-13.2 kg, mean+/-SD) performed 3 sets of supine left LP to fatigue with 90 s of rest in 4 conditions: HL (%1-RM/cuff pressure: 80%/0); LL (20%/0); LBFR(sub DBP) (20%/1.3 x diastolic blood pressure, BP); LBFR(sub SBP) (20%/1.3 x supine systolic BP). The cuff remained inflated throughout the LBFR exercise sessions. Artery diameter, velocity time integral (VTI), and stroke volume (SV) were measured using Doppler ultrasound at rest and immediately after each set of exercise. Heart rate (HR) was monitored using a 3-lead ECG. BF was calculated as VTI x vessel cross-sectional area. CO was calculated as HR x SV. The data obtained after each set of exercise were averaged and used for analyses. Multi-level modeling was used to determine the effect of exercise condition on dependent variables. Statistical significance was set a priori at p LL (9.92+/-0.82 cm3) > LBFR(sub dBP)(6.47+/-0.79 cm3) > LBFR(sub SBP) (3.51+/-0.59 cm3). Blunted exercise induced increases occurred in HR, SV, and CO after LBFR compared to HL and LL. HR increased 45% after HL and LL and 28% after LBFR (p<0.05), but SV increased (p<0.05) only after HL. Consequently, the increase (p<0.05) in CO was greater in HL and LL (approximately 3 L/min) than in LBFR (approximately 1 L/min). CONCLUSION: BF during LBFR(sub SBP) was 1/3 of that observed in LL, which supports the hypothesis that local ischemia stimulates the LBFR hypertrophic response. As the cuff did not compress the artery, the ischemia may have occurred

  19. Scalp congenital hemangioma with associated high-output cardiac failure in a premature infant: Case report and review of literature.

    Science.gov (United States)

    Shah, Sumedh S; Snelling, Brian M; Sur, Samir; Ramnath, Alexandra R; Bandstra, Emmalee S; Yavagal, Dileep R

    2017-02-01

    Introduction Scalp congenital hemangiomas (CHs) are rare vascular malformations among infants; they can be associated with an array of complications, including cardiac and cosmetic issues. Here, we report the endovascular treatment of a premature infant with a suspected large right parietal scalp hemangioma and associated high-output cardiac failure. Case description A two-day-old female premature infant (29 weeks gestational age; 1330 g birth weight) was referred by the neonatologists to our department for consultation and potential treatment of a large right parietal CH causing abrupt hypotension and high-output cardiac failure. Doppler ultrasound imaging at bedside revealed areas of arterial-venous shunting from the scalp and the presence of a superior sagittal sinus waveform, consistent with intracranial venous drainage. To alleviate cardiac dysfunction secondary to this lesion, trans-arterial embolization via n-butyl cyanoacrylate (nBCA) glue and deployment of detachable coils was performed via umbilical artery to occlude the right superficial temporal and occipital artery branches supplying the CH. Following treatment, the infant continued to require ventilator management, vasopressor support, and correction of coagulopathy, but by post-operative day two, her condition improved remarkably and the mass size began decreasing. The patient was discharged after a relatively uncomplicated subsequent 2½-month course in the neonatal intensive care unit. Conclusion Endovascular therapy proved effective and safe in treating cardiac failure associated with scalp CH, despite potential complications associated with neuro-interventional surgery in premature infants. Appropriate consideration in this patient population should be given to factors including blood loss, contrast use, radiation exposure, operative time, and possible intra-/post-operative complications.

  20. Comparison of transthoracic electrical bioimpedance cardiac output measurement with thermodilution method in post coronary artery bypass graft patients.

    Science.gov (United States)

    Sharma, Vikas; Singh, Ajmer; Kansara, Bhuvnesh; Karlekar, Anil

    2011-01-01

    Transthoracic electrical bioimpedance (TEB) has been proposed as a non-invasive, continuous, and cost-effective method of cardiac output (CO) measurement. In this prospective, non-randomized, clinical study, we measured CO with NICOMON (Larsen and Toubro Ltd., Mysore, India) and compared it with thermodilution (TD) method in patients after off-pump coronary artery bypass (OPCAB) graft surgery. We also evaluated the effect of ventilation (mechanical and spontaneous) on the measurement of CO by the two methods. Forty-six post-OPCAB patients were studied at five predefined time points during controlled ventilation and at five time points when breathing spontaneously. A total of 230 data pairs of CO were obtained. During controlled ventilation, TD CO values ranged from 2.29 to 6.74 L/min (mean 4.45 ± 0.85 L/min), while TEB CO values ranged from 1.70 to 6.90 L/min (mean 4.43 ± 0.94 L/min). The average correlation (r) was 0.548 (P = 0.0002), accompanied by a bias of 0.015 L/min and precision of 0.859 L/min. In spontaneously breathing patients, TD CO values ranged from 2.66 to 6.92 L/min (mean 4.66 ± 0.76 L/min), while TEB CO values ranged from 3.08 to 6.90 L/min (mean 4.72 ± 0.82 L/min). Their average correlation was relatively poor (r = 0.469, P= 0.002), accompanied by a bias of -0.059 L/min and precision of 0.818 L/min. The overall percent errors between TD CO and TEB CO were 19.3% (during controlled ventilation) and 17.4% (during spontaneous breathing), respectively. To conclude, a fair correlation was found between TD CO and TEB CO measurements among post-OPCAB patients during controlled ventilation. However, the correlation was weak in spontaneously breathing patients.

  1. Comparison of transthoracic electrical bioimpedance cardiac output measurement with thermodilution method in post coronary artery bypass graft patients

    Directory of Open Access Journals (Sweden)

    Sharma Vikas

    2011-01-01

    Full Text Available Transthoracic electrical bioimpedance (TEB has been proposed as a non-invasive, continuous, and cost-effective method of cardiac output (CO measurement. In this prospective, non-randomized, clinical study, we measured CO with NICOMON (Larsen and Toubro Ltd., Mysore, India and compared it with thermodilution (TD method in patients after off-pump coronary artery bypass (OPCAB graft surgery. We also evaluated the effect of ventilation (mechanical and spontaneous on the measurement of CO by the two methods. Forty-six post-OPCAB patients were studied at five predefined time points during controlled ventilation and at five time points when breathing spontaneously. A total of 230 data pairs of CO were obtained. During controlled ventilation, TD CO values ranged from 2.29 to 6.74 L/min (mean 4.45 ± 0.85 L/min, while TEB CO values ranged from 1.70 to 6.90 L/min (mean 4.43 ± 0.94 L/min. The average correlation (r was 0.548 (P = 0.0002, accompanied by a bias of 0.015 L/min and precision of 0.859 L/min. In spontaneously breathing patients, TD CO values ranged from 2.66 to 6.92 L/min (mean 4.66 ± 0.76 L/min, while TEB CO values ranged from 3.08 to 6.90 L/min (mean 4.72 ± 0.82 L/min. Their average correlation was relatively poor (r = 0.469, P= 0.002, accompanied by a bias of −0.059 L/min and precision of 0.818 L/min. The overall percent errors between TD CO and TEB CO were 19.3% (during controlled ventilation and 17.4% (during spontaneous breathing, respectively. To conclude, a fair correlation was found between TD CO and TEB CO measurements among post-OPCAB patients during controlled ventilation. However, the correlation was weak in spontaneously breathing patients.

  2. Improved hepatic arterial fraction estimation using cardiac output correction of arterial input functions for liver DCE MRI

    Science.gov (United States)

    Chouhan, Manil D.; Bainbridge, Alan; Atkinson, David; Punwani, Shonit; Mookerjee, Rajeshwar P.; Lythgoe, Mark F.; Taylor, Stuart A.

    2017-02-01

    Liver dynamic contrast enhanced (DCE) MRI pharmacokinetic modelling could be useful in the assessment of diffuse liver disease and focal liver lesions, but is compromised by errors in arterial input function (AIF) sampling. In this study, we apply cardiac output correction to arterial input functions (AIFs) for liver DCE MRI and investigate the effect on dual-input single compartment hepatic perfusion parameter estimation and reproducibility. Thirteen healthy volunteers (28.7  ±  1.94 years, seven males) underwent liver DCE MRI and cardiac output measurement using aortic root phase contrast MRI (PCMRI), with reproducibility (n  =  9) measured at 7 d. Cardiac output AIF correction was undertaken by constraining the first pass AIF enhancement curve using the indicator-dilution principle. Hepatic perfusion parameters with and without cardiac output AIF correction were compared and 7 d reproducibility assessed. Differences between cardiac output corrected and uncorrected liver DCE MRI portal venous (PV) perfusion (p  =  0.066), total liver blood flow (TLBF) (p  =  0.101), hepatic arterial (HA) fraction (p  =  0.895), mean transit time (MTT) (p  =  0.646), distribution volume (DV) (p  =  0.890) were not significantly different. Seven day corrected HA fraction reproducibility was improved (mean difference 0.3%, Bland–Altman 95% limits-of-agreement (BA95%LoA)  ±27.9%, coefficient of variation (CoV) 61.4% versus 9.3%, ±35.5%, 81.7% respectively without correction). Seven day uncorrected PV perfusion was also improved (mean difference 9.3 ml min‑1/100 g, BA95%LoA  ±506.1 ml min‑1/100 g, CoV 64.1% versus 0.9 ml min‑1/100 g, ±562.8 ml min‑1/100 g, 65.1% respectively with correction) as was uncorrected TLBF (mean difference 43.8 ml min‑1/100 g, BA95%LoA  ±586.7 ml min‑1/ 100 g, CoV 58.3% versus 13.3 ml min‑1/100 g, ±661.5 ml min‑1/100 g, 60

  3. The thick left ventricular wall of the giraffe heart normalises wall tension, but limits stroke volume and cardiac output.

    Science.gov (United States)

    Smerup, Morten; Damkjær, Mads; Brøndum, Emil; Baandrup, Ulrik T; Kristiansen, Steen Buus; Nygaard, Hans; Funder, Jonas; Aalkjær, Christian; Sauer, Cathrine; Buchanan, Rasmus; Bertelsen, Mads Frost; Østergaard, Kristine; Grøndahl, Carsten; Candy, Geoffrey; Hasenkam, J Michael; Secher, Niels H; Bie, Peter; Wang, Tobias

    2016-02-01

    Giraffes--the tallest extant animals on Earth--are renowned for their high central arterial blood pressure, which is necessary to secure brain perfusion. Arterial pressure may exceed 300 mmHg and has historically been attributed to an exceptionally large heart. Recently, this has been refuted by several studies demonstrating that the mass of giraffe heart is similar to that of other mammals when expressed relative to body mass. It thus remains unexplained how the normal-sized giraffe heart generates such massive arterial pressures. We hypothesized that giraffe hearts have a small intraventricular cavity and a relatively thick ventricular wall, allowing for generation of high arterial pressures at normal left ventricular wall tension. In nine anaesthetized giraffes (495±38 kg), we determined in vivo ventricular dimensions using echocardiography along with intraventricular and aortic pressures to calculate left ventricular wall stress. Cardiac output was also determined by inert gas rebreathing to provide an additional and independent estimate of stroke volume. Echocardiography and inert gas-rebreathing yielded similar cardiac outputs of 16.1±2.5 and 16.4±1.4 l min(-1), respectively. End-diastolic and end-systolic volumes were 521±61 ml and 228±42 ml, respectively, yielding an ejection fraction of 56±4% and a stroke volume of 0.59 ml kg(-1). Left ventricular circumferential wall stress was 7.83±1.76 kPa. We conclude that, relative to body mass, a small left ventricular cavity and a low stroke volume characterizes the giraffe heart. The adaptations result in typical mammalian left ventricular wall tensions, but produce a lowered cardiac output.

  4. GASTO CARDÍACO MATERNO COMO PREDICTOR DEL SÍNDROME DE PREECLAMPSIA-ECLAMPSIA / Maternal cardiac output as a predictor of preeclampsia-eclampsia syndrome

    Directory of Open Access Journals (Sweden)

    Luis A. Díaz Moreno

    2012-03-01

    approximately 30% of systolic volume. The research objective was to predict the onset of preeclampsia-eclampsia syndrome by identifying alterations in cardiac output. Methods: An observational, descriptive, longitudinal, analytical study of prospective cohort was performed, in which by echocardiography, the cardiac output in 31 pregnant women between weeks 11 and 13.6 of gestation was determined as the only value, and through prenatal monitoring, the presence or absence of preeclampsia-eclampsia syndrome was observed. Results: The follow-up of 31 pregnant women was achieved, to whom cardiac output was measured, with the following findings: a prevalence of disease of 12.9% with 64.5% of patients correctly diagnosed, with a sensitivity of 75%, positive predictive value of 23%, specificity of 62% and negative predictive value of 94% with a relative risk of 4.1 (95% confidence interval, 0.48 to 35.6. Conclusions: It is possible to establish cardiac output measurement as screening study to predict the onset of preeclampsia syndrome from prenatal care, thus contributing to the decline in maternal death.

  5. Low cardiac output as physiological phenomenon in hibernating, free-ranging Scandinavian brown bears (Ursus arctos) - an observational study

    DEFF Research Database (Denmark)

    Jørgensen, Peter Godsk; Arnemo, Jon; Swenson, Jon E

    2014-01-01

    hibernation in February 2013 and with medetomidine-zolazepam-tiletamine during active state in June 2013. We measured cardiac output noninvasively using estimates of hemodynamics obtained by pulsed wave Doppler echocardiography and 2D imaging. Comparisons were made using paired T-tests. RESULTS: During....... CONCLUSION: Free-ranging brown bears demonstrate hemodynamics comparable to humans during active state, whereas during hibernation, we documented extremely low-flow hemodynamics. Understanding these physiological changes in bears may help to gain insight into the mechanisms of cardiogenic shock and heart...

  6. Clinical review: Guyton--the role of mean circulatory filling pressure and right atrial pressure in controlling cardiac output.

    Science.gov (United States)

    Henderson, William R; Griesdale, Donald E G; Walley, Keith R; Sheel, A William

    2010-01-01

    Arthur Guyton's concepts of the determinative role of right heart filling in cardiac output continue to be controversial. This paper reviews his seminal experiments in detail and clarifies the often confusing concepts underpinning his model. One primary criticism of Guyton's model is that the parameters describing venous return had not been measured in a functioning cardiovascular system in humans. Thus, concerns have been expressed in regard to the ability of Guyton's simplistic model, with few parameters, to model the complex human circulation. Further concerns have been raised in regard to the artificial experimental preparations that Guyton used. Recently reported measurements in humans support Guyton's theoretical and animal work.

  7. Value of Automated ECG Interpretation in Diagnosis of Cardiac Disorders

    Directory of Open Access Journals (Sweden)

    Afsaneh Mohammadi

    2008-07-01

    Full Text Available Background: Electrocardiography (ECG is a valuable device in the assessment of cardiovascular diseases. Recent medical software developments such as the invention of modern automated ECG interpreters have greatly facilitated the work of electrocardiographers and cardiologists. We present our experience in the use of one such device in the routine reporting of 200 successive ECGs recorded in our Cardiac Care Unit and Cardiac Emergency Ward. Methods: The interpretations of 200 ECGs provided by the GE-digital ECG device were chosen and compared with those supplied by four cardiologists in a single blind manner. All statistical analyses were performed by using SPSS version 11.5 for windows. A p value of less than 0.05 was considered statistically significant.Results: There was a diagnostic match between the interpretations by the device and those by the cardiologists in 107 (53.5% cases as opposed to a diagnostic mismatch in 93 cases (46.5%. The matching rate in the interpretations of myocardial ischemic disorders was high, which means practically all the ischemic cases diagnosed by the device were confirmed by the cardiologists. Only in 12 cases myocardial infarction or ischemic changes were reported by the cardiologists, while they were missed by the device. As regards rhythm disorders, the sensitivity and specificity of the device were 67.7% and 75.7%, respectively. With respect to conductive disorders, the respective sensitivity and specificity of the device were 70% and 96.6%, respectively. Finally, in the case of structural disorders, the interpretations of the device were 92.8% sensitive and 83.3% specific.Conclusion: According to the results of our study and similar researches, it seems that the interpretations of an automated ECG device in diagnosing the ischemic and structural disorders of the heart are reliable. The device, however, should not be relied upon when assessing conduction disorders and dysrhythmias. We, therefore, recommend

  8. Combined use of phenoxybenzamine and dopamine for low cardiac output syndrome in children at withdrawal from cardiopulmonary bypass.

    Science.gov (United States)

    Kawamura, M; Minamikawa, O; Yokochi, H; Maki, S; Yasuda, T; Mizukawa, Y

    1980-04-01

    The combined use of phenoxybenzamine and dopamine was applied in infants and children when it was difficult to come off cardiopulmonary bypass for low cardiac output. The rationale of this method is to prevent the alpha-adrenergic action of dopamine by phenoxybenzamine and to encourage the beta-adrenergic and direct specific action of dopamine. Dopamine was used in dosage of 10 to 30 micrograms/kg per min after the additional administration of a half of the initial dosage of phenoxybenzamine; this was infused by drip always in a dosage of 0.5 to 1.0 mg/kg during the first half of cardiopulmonary bypass. It was possible to come off cardiopulmonary bypass with a stable haemodynamic state (mean arterial pressure more than 60 mmHg and total peripheral vascular resistance less than 2000 bynes s cm-5) and a good urinary output.

  9. Measurements of cardiac output obtained with transesophageal echocardiography and pulmonary artery thermodilution are not interchangeable

    DEFF Research Database (Denmark)

    Møller-Sørensen, H; Graeser, K; Hansen, K L

    2014-01-01

    BACKGROUND: Echocardiography is increasingly becoming an integrated tool for circulatory evaluation in the intensive care unit and the operating room. Therefore, it is imperative to know the reproducibility of measurements obtained by echocardiography. In this study, a comparison of cardiac outpu...

  10. Pulmonary Artery Catheter (PAC Accuracy and Efficacy Compared with Flow Probe and Transcutaneous Doppler (USCOM: An Ovine Cardiac Output Validation

    Directory of Open Access Journals (Sweden)

    Robert A. Phillips

    2012-01-01

    Full Text Available Background. The pulmonary artery catheter (PAC is an accepted clinical method of measuring cardiac output (CO despite no prior validation. The ultrasonic cardiac output monitor (USCOM is a noninvasive alternative to PAC using Doppler ultrasound (CW. We compared PAC and USCOM CO measurements against a gold standard, the aortic flow probe (FP, in sheep at varying outputs. Methods. Ten conscious sheep, with implanted FPs, had measurements of CO by FP, USCOM, and PAC, at rest and during intervention with inotropes and vasopressors. Results. CO measurements by FP, PAC, and USCOM were 4.0±1.2 L/min, 4.8±1.5 L/min, and 4.0±1.4 L/min, respectively, (=280, range 1.9 L/min to 11.7 L/min. Percentage bias and precision between FP and PAC, and FP and USCOM was −17 and 47%, and 1 and 36%, respectively. PAC under-measured Dobutamine-induced CO changes by 20% (relative 66% compared with FP, while USCOM measures varied from FP by 3% (relative 10%. PAC reliably detected −30% but not +40% CO changes, as measured by receiver operating characteristic area under the curve (AUC, while USCOM reliably detected ±5% changes in CO (AUC>0.70. Conclusions. PAC demonstrated poor accuracy and sensitivity as a measure of CO. USCOM provided equivalent measurements to FP across a sixfold range of outputs, reliably detecting ±5% changes.

  11. Derivation of cardiac output and alveolar ventilation rate based on energy expenditure measurements in healthy males and females.

    Science.gov (United States)

    Brochu, Pierre; Brodeur, Jules; Krishnan, Kannan

    2012-08-01

    Physiologically based pharmacokinetic modeling and occupational exposure assessment studies often use minute ventilation rates (VE), alveolar ventilation rates (VA) and cardiac outputs (Q) that are not reflective of the physiological variations encountered during the aggregate daytime activities of individuals from childhood to adulthood. These variations of VE, VA and Q values were determined for healthy normal-weight individuals aged 5-96 years by using two types of published individual data that were measured in the same subjects (n = 902), namely indirect calorimetry measurements and the disappearance rates of oral doses of deuterium (²H) and heavy-oxygen (¹⁸O) in urine monitored by gas-isotope-ratio mass spectrometry. Arteriovenous oxygen content differences (0.051-0.082 ml of O₂ consumed ml⁻¹ of blood) and ratios of the physiological dead space to the tidal volume (0.232-0.419) were determined for oxygen consumption rates (0.157-0.806 l min⁻¹) required by minute energy expenditures ranging from 0.76 to 3.91 kcal min⁻¹. Generally higher values for the 2.5th up to the 99th percentile for VE (0.132-0.774 l kg⁻¹ min⁻¹, 4.42-21.69 l m⁻² min⁻¹), VA (0.093-0.553 l kg⁻¹ min⁻¹, 3.09-15.53 l m⁻² min⁻¹), Q (0.065-0.330 l kg⁻¹ min⁻¹, 2.17 to 9.46 l m⁻² min⁻¹) and ventilation-perfusion ratios (1.12-2.16) were found in children and teenagers aged 5-<16.5 years compared with older individuals. The distributions of cardiopulmonary parameters developed in this study should be useful in facilitating a scientifically sound characterization of the inter-individual differences in the uptake and health risks of lipophilic air pollutants, particularly as they relate to younger children.

  12. Reduced peripheral arterial blood flow with preserved cardiac output during submaximal bicycle exercise in elderly heart failure

    Directory of Open Access Journals (Sweden)

    Leng Xiaoyan

    2009-11-01

    Full Text Available Abstract Background Older heart failure (HF patients exhibit exercise intolerance during activities of daily living. We hypothesized that reduced lower extremity blood flow (LBF due to reduced forward cardiac output would contribute to submaximal exercise intolerance in older HF patients. Methods and Results Twelve HF patients both with preserved and reduced left ventricular ejection fraction (LVEF (aged 68 ± 10 years without large (aorta or medium sized (iliac or femoral artery vessel atherosclerosis, and 13 age and gender matched healthy volunteers underwent a sophisticated battery of assessments including a peak exercise oxygen consumption (peak VO2, b physical function, c cardiovascular magnetic resonance (CMR submaximal exercise measures of aortic and femoral arterial blood flow, and d determination of thigh muscle area. Peak VO2 was reduced in HF subjects (14 ± 3 ml/kg/min compared to healthy elderly subjects (20 ± 6 ml/kg/min (p = 0.01. Four-meter walk speed was 1.35 ± 0.24 m/sec in healthy elderly verses 0.98 ± 0.15 m/sec in HF subjects (p p ≤ 0.03. Conclusion During CMR submaximal bike exercise in the elderly with heart failure, mechanisms other than low cardiac output are responsible for reduced lower extremity blood flow.

  13. A review of intraoperative goal-directed therapy using arterial waveform analysis for assessment of cardiac output.

    Science.gov (United States)

    Mehta, Neil; Fernandez-Bustamante, Ana; Seres, Tamas

    2014-01-01

    Increasing evidence shows that goal-directed hemodynamic management can improve outcomes in surgical and intensive care settings. Arterial waveform analysis is one of the different techniques used for guiding goal-directed therapy. Multiple proprietary systems have developed algorithms for obtaining cardiac output from an arterial waveform, including the FloTrac, LiDCO, and PiCCO systems. These systems vary in terms of how they analyze the arterial pressure waveform as well as their requirements for invasive line placement and calibration. Although small-scale clinical trials using these monitors show promising data, large-scale multicenter trials are still needed to better determine how intraoperative goal-directed therapy with arterial waveform analysis can improve patient outcomes. This review provides a comparative analysis of the different arterial waveform monitors for intraoperative goal-directed therapy.

  14. A Review of Intraoperative Goal-Directed Therapy Using Arterial Waveform Analysis for Assessment of Cardiac Output

    Directory of Open Access Journals (Sweden)

    Neil Mehta

    2014-01-01

    Full Text Available Increasing evidence shows that goal-directed hemodynamic management can improve outcomes in surgical and intensive care settings. Arterial waveform analysis is one of the different techniques used for guiding goal-directed therapy. Multiple proprietary systems have developed algorithms for obtaining cardiac output from an arterial waveform, including the FloTrac, LiDCO, and PiCCO systems. These systems vary in terms of how they analyze the arterial pressure waveform as well as their requirements for invasive line placement and calibration. Although small-scale clinical trials using these monitors show promising data, large-scale multicenter trials are still needed to better determine how intraoperative goal-directed therapy with arterial waveform analysis can improve patient outcomes. This review provides a comparative analysis of the different arterial waveform monitors for intraoperative goal-directed therapy.

  15. The clinical value of cardiac sympathetic imaging in heart failure

    DEFF Research Database (Denmark)

    Christensen, Thomas Emil; Kjaer, Andreas; Hasbak, Philip

    2014-01-01

    The autonomic nervous system plays an important role in the pathology of heart failure. The single-photon emission computed tomography tracer iodine-123-metaiodobenzylguanidine ((123) I-MIBG) can be used to investigate the activity of the predominant neurotransmitter of the sympathetic nervous...... system, norepinephrine. Also, positron emission tomography tracers are being developed for the same purpose. With (123) I-MIBG as a starting point, this brief review introduces the modalities used for cardiac sympathetic imaging....

  16. Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision.

    Science.gov (United States)

    Peyton, Philip J; Chong, Simon W

    2010-11-01

    When assessing the accuracy and precision of a new technique for cardiac output measurement, the commonly quoted criterion for acceptability of agreement with a reference standard is that the percentage error (95% limits of agreement/mean cardiac output) should be 30% or less. We reviewed published data on four different minimally invasive methods adapted for use during surgery and critical care: pulse contour techniques, esophageal Doppler, partial carbon dioxide rebreathing, and transthoracic bioimpedance, to assess their bias, precision, and percentage error in agreement with thermodilution. An English language literature search identified published papers since 2000 which examined the agreement in adult patients between bolus thermodilution and each method. For each method a meta-analysis was done using studies in which the first measurement point for each patient could be identified, to obtain a pooled mean bias, precision, and percentage error weighted according to the number of measurements in each study. Forty-seven studies were identified as suitable for inclusion: N studies, n measurements: mean weighted bias [precision, percentage error] were: pulse contour N = 24, n = 714: -0.00 l/min [1.22 l/min, 41.3%]; esophageal Doppler N = 2, n = 57: -0.77 l/min [1.07 l/min, 42.1%]; partial carbon dioxide rebreathing N = 8, n = 167: -0.05 l/min [1.12 l/min, 44.5%]; transthoracic bioimpedance N = 13, n = 435: -0.10 l/min [1.14 l/min, 42.9%]. None of the four methods has achieved agreement with bolus thermodilution which meets the expected 30% limits. The relevance in clinical practice of these arbitrary limits should be reassessed.

  17. Cardiac output by Doppler echocardiography in the premature baboon: comparison with radiolabeled microspheres.

    Science.gov (United States)

    Kinsella, J P; Morrow, W R; Gerstmann, D R; Taylor, A F; deLemos, R A

    1991-04-01

    Pulsed-Doppler echocardiography (PDE) is a useful noninvasive method for determining left ventricular output (LVO). However, despite increasingly widespread use in neonatal intensive care units, validation studies in prematures with cardiopulmonary disease are lacking. The purpose of this study was to compare radiolabeled microsphere (RLM) and PDE measurements of LVO, using the critically ill premature baboon as a model of the human neonate. Twenty-two paired RLM and PDE measurements of LVO were obtained in 14 animals between 3 and 24 h of age. Average PDE LVO was 152 ml/min/kg (range, 40-258 ml/min/kg) compared to 158 ml/min/kg (range, 67-278 ml/min/kg) measured by RLM. Linear regression analysis of the paired measurements showed good correlation with a slope near unity (gamma = 0.94x + 4.20, r = 0.91, SEE = 25.7 ml). We conclude that PDE determinations of LVO compare well with those measured by RLM in the premature baboon. PDE appears to provide a valid estimate of LVO and should be useful in human prematures with cardiopulmonary distress.

  18. Calibrated versus uncalibrated arterial pressure waveform analysis in monitoring cardiac output with transpulmonary thermodilution in patients with severe sepsis and septic shock: an observational study

    NARCIS (Netherlands)

    Slagt, C.; Helmi, M.; Malagon, I.; Groeneveld, A.B.

    2015-01-01

    BACKGROUND: Cardiac output (CO) measurement is often required in critically ill patients. The performances of newer, less invasive techniques require evaluation in patients with severe sepsis and septic shock. OBJECTIVES: To compare calibrated arterial pressure waveform analysis-derived CO (COap, Vo

  19. Assessing the treatment costs and the fertilizing value of the output products in digestate treatment systems.

    Science.gov (United States)

    Golkowska, K; Vázquez-Rowe, I; Lebuf, V; Accoe, F; Koster, D

    2014-01-01

    The objective of this paper was to advance towards finding sustainable solutions to deal with biogas digestate and contribute to faster development of the market for digestate treatment products. The study compares digestate treatment costs through four different treatment plants, estimates the potential fertilizing and humus value (PFHV) of the derived products and allocates the cash flows to show the possible regional benefits. The treatment costs for the pre-dried solid fraction of digestate ranged from €19 to €23/tonne output. These costs may be covered by vending treatment products at a price reaching at least 34-41% of their PFHV (ca €55/tonne). Treatment of raw digestate generates high operating costs (€216-247/tonne output), much higher than the PFHV of the products (ca €35-51/tonne). For such systems either the treatment has to be financially subsidized by the authorities or €13-32/tonne input should be covered by the substrate deliverers as a disposal fee. Nevertheless, a well-prepared investment concept in this field may allow the local binding of up to 80% of total cash flows. Finally, the current difficult market situation of the treatment products can be primarily improved by clearing their legal status at European level.

  20. Fetal cardiac ventricular volume, cardiac output, and ejection fraction determined with four-dimensional ultrasound using Spatio-Temporal Image Correlation (STIC) and Virtual Organ Computed-aided AnaLysis (VOCAL™)

    Science.gov (United States)

    Hamill, Neil; Yeo, Lami; Romero, Roberto; Hassan, Sonia S.; Myers, Stephen A.; Mittal, Pooja; Kusanovic, Juan Pedro; Balasubramaniam, Mamtha; Chaiworapongsa, Tinnakorn; Vaisbuch, Edi; Espinoza, Jimmy; Gotsch, Francesca; Goncalves, Luis F.; Lee, Wesley

    2011-01-01

    Objective To quantify fetal cardiovascular parameters with Spatio-Temporal Image Correlation (STIC) and Virtual Organ Computed-aided AnaLysis (VOCAL™) utilizing the sub-feature: “Contour Finder: Trace”. Study Design A cross-sectional study was designed consisting of patients with normal pregnancies between 19 and 40 weeks of gestation. After STIC datasets were acquired, analysis was performed offline (4DView) and the following cardiovascular parameters were evaluated: ventricular volume in end systole and end diastole, stroke volume, cardiac output, and ejection fraction. To account for fetal size, cardiac output was also expressed as a function of head circumference, abdominal circumference, or femoral diaphysis length. Regression models were fitted for each cardiovascular parameter to assess the effect of gestational age and paired comparisons were made between the left and right ventricles. Results 1) Two hundred and seventeen patients were retrospectively identified, of whom 184 had adequate STIC datasets (85% acceptance); 2) ventricular volume, stroke volume, cardiac output, and adjusted cardiac output increased with gestational age; whereas, the ejection fraction decreased as gestation advanced; 3) the right ventricle was larger than the left in both systole (Right: 0.50 ml, IQR: 0.2 – 0.9; vs. Left: 0.27 ml, IQR: 0.1 – 0.5; p<0.001) and diastole (Right: 1.20 ml, IQR: 0.7 – 2.2; vs. Left: 1.03 ml, IQR: 0.5 – 1.7; p<0.001); 4) there were no differences between the left and right ventricle with respect to stroke volume, cardiac output, or adjusted cardiac output; and 5) the left ventricular ejection fraction was greater than the right (Left: 72.2%, IQR: 64 – 78; vs. Right: 62.4%, IQR: 56 – 69; p<0.001). Conclusion Fetal echocardiography, utilizing STIC and VOCAL™ with the sub-feature: “Contour Finder: Trace”, allows assessment of fetal cardiovascular parameters. Normal fetal cardiovascular physiology is characterized by ventricular

  1. Plasma volume expansion does not increase maximal cardiac output or VO2 max in lowlanders acclimatized to altitude.

    Science.gov (United States)

    Calbet, José A L; Rådegran, Göran; Boushel, Robert; Søndergaard, Hans; Saltin, Bengt; Wagner, Peter D

    2004-09-01

    With altitude acclimatization, blood hemoglobin concentration increases while plasma volume (PV) and maximal cardiac output (Qmax) decrease. This investigation aimed to determine whether reduction of Qmax at altitude is due to low circulating blood volume (BV). Eight Danish lowlanders (3 females, 5 males: age 24.0 +/- 0.6 yr; mean +/- SE) performed submaximal and maximal exercise on a cycle ergometer after 9 wk at 5,260 m altitude (Mt. Chacaltaya, Bolivia). This was done first with BV resulting from acclimatization (BV = 5.40 +/- 0.39 liters) and again 2-4 days later, 1 h after PV expansion with 1 liter of 6% dextran 70 (BV = 6.32 +/- 0.34 liters). PV expansion had no effect on Qmax, maximal O2 consumption (VO2), and exercise capacity. Despite maximal systemic O2 transport being reduced 19% due to hemodilution after PV expansion, whole body VO2 was maintained by greater systemic O2 extraction (P VO2 during exercise regardless of PV. Pulmonary ventilation, gas exchange, and acid-base balance were essentially unaffected by PV expansion. Sea level Qmax and exercise capacity were restored with hyperoxia at altitude independently of BV. Low BV is not a primary cause for reduction of Qmax at altitude when acclimatized. Furthermore, hemodilution caused by PV expansion at altitude is compensated for by increased systemic O2 extraction with similar peak muscular O2 delivery, such that maximal exercise capacity is unaffected.

  2. Diesel Exhaust Inhalation Increases Cardiac Output, Bradyarrhythmias, and Parasympathetic Tone in Aged Heart Failure-Prone Rats

    Science.gov (United States)

    Acute air pollutant inhalation is linked to adverse cardiac events and death, and hospitalizations for heart failure. Diesel exhaust (DE) is a major air pollutant suspected to exacerbate preexisting cardiac conditions, in part, through autonomic and electrophysiologic disturbance...

  3. Cardiac output monitoring

    NARCIS (Netherlands)

    de Waal, Eric. E. C.; Wappler, Frank; Buhre, Wolfgang F.

    2009-01-01

    Purpose of review The primary goal of hemodynamic therapy is the prevention of inadequate tissue perfusion and inadequate oxygenation. Advanced cardiovascular monitoring is a prerequisite to optimize hemodynamic treatment in critically ill patients prone to cardiocirculatory failure. The most ideal

  4. Prognostic value of sympathetic innervation and cardiac asynchrony in dilated cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Manrique, Alain; Hitzel, Anne; Vera, Pierre [Rouen University Hospital - Henri Becquerel Center, Nuclear Medicine, Rouen (France); Bernard, Mathieu; Bauer, Fabrice [Rouen University Hospital, Cardiology, Rouen (France); Menard, Jean-Francois [Rouen University Hospital, Biostatistics, Rouen (France); Sabatier, Remi [Caen University Hospital, Cardiology, Caen (France); Jacobson, Arnold [GE Healthcare, Princeton, NJ (United States); Agostini, Denis [Caen University Hospital, Nuclear Medicine, Caen (France)

    2008-11-15

    The purpose of the study is to examine prognostic values of cardiac I-123 metaiodobenzylguanidine (MIBG) uptake and cardiac dyssynchrony in patients with dilated cardiomyopathy (DCM). Ninety-four patients with non-ischemic DCM underwent I-123 MIBG imaging for assessing cardiac sympathetic innervation and equilibrium radionuclide angiography. Mean phase angles and SD of the phase histogram were computed for both right ventricular (RV) and left ventricular (LV). Phase measures of interventricular (RV-LV) and intraventricular (SD-RV and SD-LV) asynchrony were computed. Most patients were receiving beta-blockers (89%) and angiotensin-converting enzyme inhibitors (88%). One patient (1%) was lost to follow-up, six had cardiac death (6.4%), eight had heart transplantation (8.6%), and seven had unplanned hospitalization for heart failure (7.5%; mean follow-up: 37 {+-} 16 months). Patients with poor clinical outcome were older, had higher The New York Heart Association functional class, impaired right ventricular ejection fraction and left ventricular ejection fraction, and impaired cardiac I-123 MIBG uptake. On multivariate analysis, I-123 MIBG heart-to-mediastinum (H/M) uptake ratio <1.6 was the only predictor of both primary (cardiac death or heart transplantation, RR = 7.02, p < 0.01) and secondary (cardiac death, heart transplantation, or recurrent heart failure, RR = 8.10, p = 0.0008) end points. In patients receiving modern medical therapy involving beta-blockers, I-123 MIBG uptake, but not intra-LV asynchrony, was predictive of clinical outcome. The impact of beta-blockers on the prognostic value of ventricular asynchrony remains to be clarified. (orig.)

  5. Accuracy and precision of minimally-invasive cardiac output monitoring in children: a systematic review and meta-analysis.

    Science.gov (United States)

    Suehiro, Koichi; Joosten, Alexandre; Murphy, Linda Suk-Ling; Desebbe, Olivier; Alexander, Brenton; Kim, Sang-Hyun; Cannesson, Maxime

    2016-10-01

    Several minimally-invasive technologies are available for cardiac output (CO) measurement in children, but the accuracy and precision of these devices have not yet been evaluated in a systematic review and meta-analysis. We conducted a comprehensive search of the medical literature in PubMed, Cochrane Library of Clinical Trials, Scopus, and Web of Science from its inception to June 2014 assessing the accuracy and precision of all minimally-invasive CO monitoring systems used in children when compared with CO monitoring reference methods. Pooled mean bias, standard deviation, and mean percentage error of included studies were calculated using a random-effects model. The inter-study heterogeneity was also assessed using an I(2) statistic. A total of 20 studies (624 patients) were included. The overall random-effects pooled bias, and mean percentage error were 0.13 ± 0.44 l min(-1) and 29.1 %, respectively. Significant inter-study heterogeneity was detected (P error (23.6 %). Significant residual heterogeneity remained after conducting sensitivity and subgroup analyses based on the various study characteristics. By meta-regression analysis, we found no independent effects of study characteristics on weighted mean difference between reference and tested methods. Although the pooled bias was small, the mean pooled percentage error was in the gray zone of clinical applicability. In the sub-group analysis, electrical cardiometry was the device that provided the most accurate measurement. However, a high heterogeneity between studies was found, likely due to a wide range of study characteristics.

  6. Value of plasma ADMA in predicting cardiac structure and function of patients with chronic kidney diseases

    Institute of Scientific and Technical Information of China (English)

    叶建华

    2012-01-01

    Objective To explore the predicting value of plasma asymmetric dimethylarginine (ADMA) in cardiac structure and function of patients with chronic kidney diseases(CKD). Methods A total of 100 CKD patients were enrolled in this cross-sectional study. According to staging of the

  7. Importance of re-calibration time on pulse contour analysis agreement with thermodilution measurements of cardiac output: a retrospective analysis of intensive care unit patients.

    Science.gov (United States)

    Scully, Christopher G; Gomatam, Shanti; Forrest, Shawn; Strauss, David G

    2016-10-01

    We assessed the effect of re-calibration time on cardiac output estimation and trending performance in a retrospective analysis of an intensive care unit patient population using error grid analyses. Paired thermodilution and arterial blood pressure waveform measurements (N = 2141) from 222 patient records were extracted from the Multiparameter Intelligent Monitoring in Intensive Care II database. Pulse contour analysis was performed by implementing a previously reported algorithm at calibration times of 1, 2, 8 and 24 h. Cardiac output estimation agreement was assessed using Bland-Altman and error grid analyses. Trending was assessed by concordance and a 4-Quadrant error grid analysis. Error between pulse contour and thermodilution increased with longer calibration times. Limits of agreement were -1.85 to 1.66 L/min for 1 h maximum calibration time compared to -2.70 to 2.41 L/min for 24 h. Error grid analysis resulted in 74.2 % of points bounded by 20 % error limits of thermodilution measurements for 1 h calibration time compared to 65 % for 24 h. 4-Quadrant error grid analysis showed analysis method and thermodilution showed poor agreement to monitor changes in cardiac output.

  8. Differences of cardiac output measurements by open-circuit acetylene uptake in pulmonary arterial hypertension and chronic thromboembolic pulmonary hypertension: a cohort study

    Directory of Open Access Journals (Sweden)

    Schwaiblmair Martin

    2012-03-01

    Full Text Available Abstract Background As differences in gas exchange between pulmonary arterial hypertension (PAH and chronic thromboembolic pulmonary hypertension (CTEPH have been demonstrated, we asked if cardiac output measurements determined by acetylene (C2H2 uptake significantly differed in these diseases when compared to the thermodilution technique. Method Single-breath open-circuit C2H2 uptake, thermodilution, and cardiopulmonary exercise testing were performed in 72 PAH and 32 CTEPH patients. Results In PAH patients the results for cardiac output obtained by the two methods showed an acceptable agreement with a mean difference of -0.16 L/min (95% CI -2.64 to 2.32 L/min. In contrast, the agreement was poorer in the CTEPH group with the difference being -0.56 L/min (95% CI -4.96 to 3.84 L/min. Functional dead space ventilation (44.5 ± 1.6 vs. 32.2 ± 1.4%, p 2 gradient (9.9 ± 0.8 vs. 4.1 ± 0.5 mmHg, p Conclusion Cardiac output evaluation by the C2H2 technique should be interpreted with caution in CTEPH, as ventilation to perfusion mismatching might be more relevant than in PAH.

  9. Statistical testing procedure for the interaction effects of several controllable factors in two-valued input-output systems

    OpenAIRE

    Aoki, Satoshi; Miyakawa, Masami

    2007-01-01

    Suppose several two-valued input-output systems are designed by setting the levels of several controllable factors. For this situation, Taguchi method has proposed to assign the controllable factors to the orthogonal array and use ANOVA model for the standardized SN ratio, which is a natural measure for evaluating the performance of each input-output system. Though this procedure is simple and useful in application indeed, the result can be unreliable when the estimated standard errors of the...

  10. Cardiac output measured by electrical velocimetry in the CT suite correlates with coronary artery enhancement: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Flinck, Marianne; Graden, Aasa; Milde, Helen; Flinck, Agneta; Hellstroem, Mikael (Dept. of Radiology, Sahlgrenska Univ. Hospital and Sahlgrenska Academy at Goetenborg Univ., Goeteborg (Sweden)); Bjoerk, Jonas (Competence Centre for Clinical Research, Lund Univ. Hospital, Lund (Sweden)); Nyman, Ulf (Dept. of Radiology, Lasarettet Trelleborg, Univ. of Lund, Trelleborg (Sweden)), e-mail: ulf.nyman@skane.se

    2010-10-15

    Background: Cardiac output (CO) is inversely related to vascular contrast medium (CM) enhancement during computed tomography (CT). Impedance cardiography with a new technique, electrical velocimetry (EV), may create opportunities to measure CO pre-examination for adaptation of CM injection parameters. Purpose: To relate COEV measured by radiology staff to aortic attenuation as a measure of coronary artery attenuation during CT coronary angiography (CTCA), and to formulate a tentative statistical model to adapt CM injection parameters to CO. Material and Methods: COEV was measured immediately before 100 kVp CTCA (64-multirow detector) in 27 patients with presumed coronary artery disease. For CTCA, 260 mg I/kg (maximum dosage weight: 80/90 kg for women/men) was injected intravenously during 12 s. Simple linear regression analysis was performed to explore the correlation between aortic attenuation (Hounsfield units, HU) and body weight, the influence of COEV on aortic attenuation adjusted to injected CM dose rate (HU per mg I/kg/s), and to establish a tentative formula on how to adapt CM injection parameters to COEV and desired aortic attenuation. Results: The correlation between aortic attenuation and body weight was weak and non-significant (r=-0.14 after outlier exclusion). A significant negative correlation (r=-0.63) was found between aortic attenuation adjusted to injected CM dose rate (HU per mg I/kg/s) and COEV. The resulting formula, CM dose rate=COEVx(aortic attenuation-240)/55, made it possible to calculate CM volumes and injection rates at various COs and, for example, the present mean aortic attenuation (438 HU), injection time (12 s), CM concentration (320 mg I/ml), and a certain body weight. Conclusion: EV makes it possible to measure CO in the CT suite before vascular examinations. Hence, CM doses may be decreased in low CO states to reduce the risk of CM-induced nephropathy without jeopardizing diagnostic quality and may be increased in high CO states

  11. Impact of changes in systemic vascular resistance on a novel non-invasive continuous cardiac output measurement system based on pulse wave transit time: a report of two cases.

    Science.gov (United States)

    Ishihara, Hironori; Tsutsui, Masato

    2014-08-01

    The inaccuracy of arterial waveform analysis for measuring continuos cardiac output (CCO) associated with changes in systemic vascular resistance (SVR) has been well documented. A new non-invasive continuous cardiac output monitoring system (esCCO) mainly utilizing pulse wave transit time (PWTT) in place of arterial waveform analysis has been developed. However, the trending ability of esCCO to measure cardiac output during changes in SVR remains unclear. After a previous multicenter study on esCCO measurement, we retrospectively identified two cases in which apparent changes in SVR developed in a short period during data collection. In each case, the trending ability of esCCO to measure cardiac output and time component of PWTT were analyzed. Recorded data suggest that the time component of PWTT may have a significant impact on the accuracy of estimating stroke volume during changes in SVR. However, further prospective clinical studies are required to test this hypothesis.

  12. The Value of Picture-Book Reading-Based Collaborative Output Activities for Vocabulary Retention

    Science.gov (United States)

    Sun, Chia-Ho

    2017-01-01

    This study investigated the effects of three instructional modes: picture-book reading-only (PRO), picture-book reading plus vocabulary instruction (PRVI), and picture-book reading plus reading-based collaborative output activity (PRCOA) on young adult EFL (English as a foreign language) learners' vocabulary acquisition and retention. Eighty…

  13. Substrate stiffness-regulated matrix metalloproteinase output in myocardial cells and cardiac fibroblasts: implications for myocardial fibrosis.

    Science.gov (United States)

    Xie, Jing; Zhang, Quanyou; Zhu, Ting; Zhang, Yanyan; Liu, Bailin; Xu, Jianwen; Zhao, Hucheng

    2014-06-01

    Cardiac fibrosis, an important pathological feature of structural remodeling, contributes to ventricular stiffness, diastolic dysfunction, arrhythmia and may even lead to sudden death. Matrix stiffness, one of the many mechanical factors acting on cells, is increasingly appreciated as an important mediator of myocardial cell behavior. Polydimethylsiloxane (PDMS) substrates were fabricated with different stiffnesses to mimic physiological and pathological heart tissues, and the way in which the elastic modulus of the substrate regulated matrix-degrading gelatinases in myocardial cells and cardiac fibroblasts was explored. Initially, an increase in cell spreading area was observed, concomitant with the increase in PDMS stiffness in both cells. Later, it was demonstrated that the MMP-2 gene expression and protein activity in myocardial cells and cardiac fibroblasts can be enhanced with an increase in PDMS substrate stiffness and, moreover, such gene- and protein-related increases had a significant linear correlation with the elastic modulus. In comparison, the MMP-9 gene and protein expressions were up-regulated in cardiac fibroblasts only, not in myocardial cells. These results implied that myocardial cells and cardiac fibroblasts in the myocardium could sense the stiffness in pathological fibrosis and showed a differential but positive response in the expression of matrix-degrading gelatinases when exposed to an increased stiffening of the matrix in the microenvironment. The phenomenon of cells sensing pathological matrix stiffness can help to increase understanding of the mechanism underlying myocardial fibrosis and may ultimately lead to planning cure strategies.

  14. Comparing the accuracy of ES-BC, EIS-GS, and ES Oxi on body composition, autonomic nervous system activity, and cardiac output to standardized assessments

    Directory of Open Access Journals (Sweden)

    Lewis JE

    2011-09-01

    Full Text Available John E Lewis1, Stacey L Tannenbaum1, Jinrun Gao3, Angelica B Melillo1, Evan G Long1, Yaima Alonso2, Janet Konefal1, Judi M Woolger2, Susanna Leonard1, Prabjot K Singh1, Lawrence Chen1, Eduard Tiozzo1 1Department of Psychiatry and Behavioral Sciences, 2Department of Medicine, University of Miami Miller School of Medicine, Miami, FL, 3State Farm Insurance, Bloomington, IL, USA Background and purpose: The Electro Sensor Complex (ESC is software that combines three devices using bioelectrical impedance, galvanic skin response, and spectrophotometry: (1 ES-BC (Electro Sensor-Body Composition; LD Technology, Miami, FL to assess body composition, (2 EIS-GS (Electro Interstitial Scan-Galvanic Skin; LD Technology to predict autonomic nervous system activity, and (3 ES Oxi (Electro Sensor Oxi; LD Technology to assess cardiac output. The objective of this study was to compare each to a standardized assessment: ES-BC to dual-energy X-ray absorptiometry (DXA, EIS-GS to heart rate variability, and ES Oxi to BioZ Dx Diagnostic System (BioZ Dx; SonoSite Inc, Bothell, WA. Patients and methods: The study was conducted in two waves. Fifty subjects were assessed for body composition and autonomic nervous system activity. Fifty-one subjects were assessed for cardiac output. Results: We found adequate relative and absolute agreement between ES-BC and DXA for fat mass (r = 0.97, P < 0.001 with ES-BC overestimating fat mass by 0.1 kg and for body fat percentage (r = 0.92, P < 0.001 with overestimation of fat percentage by 0.4%. For autonomic nervous system activity, we found marginal relative agreement between EIS-GS and heart rate variability by using EIS-GS as the predictor in a linear regression equation (adjusted R2 = 0.56, P = 0.03. For cardiac output, adequate relative and absolute agreement was found between ES Oxi and BioZ Dx at baseline (r = 0.60, P < 0.001, after the first exercise stage (r = 0.79, P < 0.001, and after the second exercise stage (r = 0.86, P

  15. Glucagon-like peptide-1 (7-36) but not (9-36) augments cardiac output during myocardial ischemia via a Frank-Starling mechanism.

    Science.gov (United States)

    Goodwill, Adam G; Tune, Johnathan D; Noblet, Jillian N; Conteh, Abass M; Sassoon, Daniel; Casalini, Eli D; Mather, Kieren J

    2014-01-01

    This study examined the cardiovascular effects of GLP-1 (7-36) or (9-36) on myocardial oxygen consumption, function and systemic hemodynamics in vivo during normal perfusion and during acute, regional myocardial ischemia. Lean Ossabaw swine received systemic infusions of saline vehicle or GLP-1 (7-36 or 9-36) at 1.5, 3.0, and 10.0 pmol/kg/min in sequence for 30 min at each dose, followed by ligation of the left circumflex artery during continued infusion at 10.0 pmol/kg/min. Systemic GLP-1 (9-36) had no effect on coronary flow, blood pressure, heart rate or indices of cardiac function before or during regional myocardial ischemia. Systemic GLP-1 (7-36) exerted no cardiometabolic or hemodynamic effects prior to ischemia. During ischemia, GLP-1 (7-36) increased cardiac output by approximately 2 L/min relative to vehicle-controls (p = 0.003). This response was not diminished by treatment with the non-depolarizing ganglionic blocker hexamethonium. Left ventricular pressure-volume loops measured during steady-state conditions with graded occlusion of the inferior vena cava to assess load-independent contractility revealed that GLP-1 (7-36) produced marked increases in end-diastolic volume (74 ± 1 to 92 ± 5 ml; p = 0.03) and volume axis intercept (8 ± 2 to 26 ± 8; p = 0.05), without any change in the slope of the end-systolic pressure-volume relationship vs. vehicle during regional ischemia. GLP-1 (9-36) produced no changes in any of these parameters compared to vehicle. These findings indicate that short-term systemic treatment with GLP-1 (7-36) but not GLP-1 (9-36) significantly augments cardiac output during regional myocardial ischemia, via increases in ventricular preload without changes in cardiac inotropy.

  16. Clinical value of high-sensitivity cardiac troponin assays after acute ischemic stroke

    Directory of Open Access Journals (Sweden)

    Yi-rui CAO

    2016-11-01

    Full Text Available In view of a variety of cardiovascular events complicated by acute ischemic stroke, the importance of monitoring myocardial ischemic symptoms and signs, electrocardiogram, echocardiogram and myocardial injury markers has been gradually recognized by clinicians. Cardiac troponin (cTn by conventional assay has been a unique marker of myocardial injury for its extremely high specificity. However, with the utilization of high-sensitivity cardiac troponin (hs-cTn, cTn is no longer exclusive of a disease, but was given more significance in the diagnosis and application value. Therefore, we described the clinical significance of alterations of serum hs-cTn concentration after ischemic stroke. DOI: 10.3969/j.issn.1672-6731.2016.11.015

  17. Prognostic value of high-sensitivity cardiac troponin T in patients with en-domyocardial-biopsy proven cardiac amyloidosis

    Institute of Scientific and Technical Information of China (English)

    Geng QIAN; Chen WU; Yang ZHANG; Yun-Dai CHEN; Wei DONG; Yi-Hong REN

    2014-01-01

    Objective To investigate prognostic predictors of long-term survival of patients with cardiac amyloidosis (CA), and to determine predictive value of high-sensitivity cardiac troponin T (hs-cTnT) in CA patients. Methods We recruited 102 consecutive CA cases and followed these patients for 5 years. We described their clinical characteristics at presentation and used a new, high-sensitivity assay to determine the concentration of cTnT in plasma samples from these patients. Results The patients with poor prognosis showed older age (56 ±12 years vs. 50 ±15 years, P=0.022), higher incidences of heart failure (36.92%vs. 16.22%, P=0.041), pericardial effusion (60.00%vs. 35.14%, P=0.023), greater thickness of interventricular septum (IVS) (15 ±4 mm vs. 13 ±4 mm, P=0.034), higher level of hs-cTnT (0.186 ±0.249 ng/mL vs. 0.044 ±0.055 ng/mL, P=0.001) and higher NT-proBNP (N-terminal pro-B-type natriuretic pep-tide) levels (11,742 ± 10,464 pg/mL vs. 6,031 ± 7,458 pg/mL, P=0.006). At multivariate Cox regression analysis, heart failure (HR:1.78, 95%CI:1.09-2.92, P=0.021), greater wall thickness of IVS (HR:1.44, 95%CI:1.04-3.01, P=0.0375) and higher hs-cTnT level (HR:6.16, 95%CI:2.20-17.24, P=0.001) at enrollment emerged as independent predictors of all-cause mortality. Conclusions We showed that hs-cTnT is associated with a very ominous prognosis, and it is also the strongest predictor of all-cause mortality in multivariate analysis. Examination of hs-cTnT concentrations provides valuable prognostic information concerning long-term outcomes.

  18. Prognostic value of cardiac biomarkers in the risk stratification of syncope: a systematic review.

    Science.gov (United States)

    Thiruganasambandamoorthy, Venkatesh; Ramaekers, Rosa; Rahman, Mohammed Omair; Stiell, Ian Gilmour; Sikora, Lindsey; Kelly, Sarah-Louise; Christ, Michael; Claret, Pierre-Geraud; Reed, Matthew James

    2015-12-01

    The role of cardiac biomarkers in risk stratification of syncope is unclear. We undertook a systematic review to assess their predictive value for short-term major adverse cardiovascular events (MACE). We conducted a systematic review using MEDLINE, EMBASE, DARE and Cochrane databases from inception to July 2014. We included studies involving adult syncope patients that evaluated cardiac biomarker levels for risk stratification during acute management and excluded case reports, reviews and studies involving children. Primary outcome (MACE) included death, cardiopulmonary resuscitation, myocardial infarction (MI), structural heart disease, pulmonary embolism, significant hemorrhage or cardiac procedural interventions. Secondary outcome analysis assessed for prediction of MI, cardiac syncope and death. Two reviewers extracted patient-level data based on the cut-off reported. Pooled sensitivities and specificities were calculated using patient-level data. A total of 1862 articles were identified, and 11 studies with 4246 patients were included. Studies evaluated 3 biomarkers: contemporary troponin (2693 patients), natriuretic peptides (1353 patients) and high-sensitive troponin (819 patients). The pooled sensitivities and specificities for MACE were: contemporary troponin 0.29 (95 % CI 0.24, 0.34) and 0.88 (95 % CI 0.86, 0.89); natriuretic peptides 0.77 (95 % CI 0.69, 0.85) and 0.73 (95 % CI 0.70, 0.76); high-sensitive troponin 0.74 (95 % CI 0.65, 0.83) and 0.65 (95 % CI 0.62, 0.69), respectively. Natriuretic peptides and high-sensitive troponin showed good diagnostic characteristics for both primary and secondary outcomes. Natriuretic peptides and high-sensitive troponin might be useful in risk stratification.

  19. 连续多普勒无创血液动力学监测仪(USCOM)在危重患者中的运用%The Application of Ultrasonic Cardiac Output Monitor In the Critically Ill Patients

    Institute of Scientific and Technical Information of China (English)

    杨勤; 向明芳

    2012-01-01

    Objective: To compare the cardiac output detected by ultrasonic cardiac output monitor(USCOM) and Thoracic Electrical Bioimpedance(TEB). Methods: The cardiac outputs of 40 critically ill patients were detected by USCOM and TEB simultaneously. Results: There was no significant difference of the cardiac output detected by USCOM and TEB(P>0.10), the correlation analysis showed a positive correlation between cardiac output measured with USCOM and TEB(correlation coefficient of CO: r=0.8427, correlation coefficient of SV: r=0.8392, P0.10);且两种监测方法测得的结果具有正相关性(CO相关系数 r=0.8427,SV相关系数 r=0.8392,P均<0.01).结论采用USCOM技术监测危重患者的心输出量具有无创、连续、简便、准确的特点.

  20. Comparison of cardiac power output and exercise performance in patients with left ventricular assist devices, explanted (recovered) patients, and those with moderate to severe heart failure.

    Science.gov (United States)

    Jakovljevic, Djordje G; George, Robert S; Donovan, Gay; Nunan, David; Henderson, Keiran; Bougard, Robert S; Yacoub, Magdi H; Birks, Emma J; Brodie, David A

    2010-06-15

    Peak cardiac power output (CPO), as a direct measurement of overall cardiac function, has been shown to be a most powerful predictor of prognosis for patients with chronic heart failure. The present study assessed CPO and exercise performance in patients implanted with a left ventricular assist device (LVAD), those explanted due to myocardial recovery, and those with moderate to severe heart failure. Hemodynamic and respiratory gas exchange measurements were undertaken at rest and at peak graded exercise. These were performed in 54 patients-20 with moderate to severe heart failure, 18 with implanted LVADs, and 16 with explanted LVADs. At rest there was a nonsignificant difference in CPO among groups (p >0.05). Peak CPO was significantly higher in the explanted LVAD than in the heart failure and implanted LVAD groups (heart failure 1.90 +/- 0.45 W, implanted LVAD 2.37 +/- 0.55 W, explanted LVAD 3.39 +/- 0.61 W, p <0.01) as was peak cardiac output (heart failure 9.1 +/- 2.1 L/min, implanted LVAD 12.4 +/- 2.2 L/min, explanted LVD 14.6 +/- 2.9 L/min, p <0.01). Peak oxygen consumption was higher in the explanted LVAD than in the heart failure and implanted LVAD groups (heart failure 15.8 +/- 4.1 ml/kg/min, implanted LVAD 19.8 +/- 5.8 ml/kg/min, explanted LVAD 28.2 +/- 5.0 ml/kg/min, p <0.05) as was anaerobic threshold (heart failure 11.2 +/- 1.9 ml/kg/min, implanted LVAD 14.7 +/- 4.9 ml/kg/min, explanted LVAD 21.4 +/- 5.0 ml/kg/min, p <0.05). In conclusion, peak CPO differentiates well during cardiac restoration using LVADs and emphasizes the benefits of this therapy. CPO has the potential to be a key physiologic marker of heart failure severity and can guide management of patients with LVAD.

  1. [Effects of planting system on soil and water conservation and crop output value in a sloping land of Southwest China].

    Science.gov (United States)

    Xiang, Da-Bing; Yong, Tai-Wen; Yang, Wen-Yu; Yu, Xiao-Bo; Guo, Kai

    2010-06-01

    A three-year experiment was conducted to study the effects of wheat/maize/soybean with total no-tillage and mulching (NTM), wheat/maize/soybean with part no-tillage and part mulching (PTM), wheat/maize/soybean with total tillage without mulching (TWM), and wheat/maize/ sweet potato with total tillage without mulching (TWMS) on the soil and water conservation, soil fertility, and crop output value in a sloping land of Southwest China. The average soil erosion amount and surface runoff of NTM were significantly lower than those of the other three planting systems, being 1189 kg x hm(-2) and 215 m3 x hm(-2), and 10.6% and 84.7% lower than those of TWMS, respectively. The soil organic matter, total N, available K and available N contents of NTM were increased by 15.7%, 18.2%, 55.2%, and 25.9%, respectively, being the highest among the test planting systems. PTM and TWM took the second place, and TWMS pattern had the least. NTM had the highest annual crop output value (18809 yuan x hm(-2)) and net income (12619 yuan x hm(-2)) in three years, being 2.2% -20.6% and 3.8% -32.9% higher than other three planting systems, respectively. In a word, the planting system wheat/maize/soybean was more beneficial to the water and soil conservation and the improvement of soil fertility and crop output value, compared with the traditional planting system wheat/maize/sweet potato.

  2. G16R single nucleotide polymorphism but not haplotypes of the ß2-adrenergic receptor gene alters cardiac output in humans

    DEFF Research Database (Denmark)

    Rokamp, Kim Z; Staalsø, Jonatan M; Gartmann, Martin

    2013-01-01

    Variation in genes encoding the ß2-adrenergic receptor (ADRB2) and angiotensin-converting enzyme (ACE) may influence Q¿ (cardiac output). The 46G>A (G16R) SNP (single nucleotide polymorphism) has been associated with ß2-mediated vasodilation, but the effect of ADRB2 haplotypes on Q¿ has not been...... studied. Five SNPs within ADRB2 (46G>A, 79C>G, 491C>T, 523C>A and 1053G>C by a pairwise tagging principle) and the I/D (insertion/deletion) polymorphism in ACE were genotyped in 143 subjects. Cardiovascular variables were evaluated by the Model flow method at rest and during incremental cycling exercise...

  3. Use of transesophageal Doppler as a sole cardiac output monitor for reperfusion hemodynamic changes during living donor liver transplantation: An observational study

    Directory of Open Access Journals (Sweden)

    M Hussien

    2011-01-01

    Full Text Available Aims: To report the use of transesophageal Doppler (TED, a minimally invasive cardiac output (COP monitor, before, during and after reperfusion and study its effect on anesthetic management during living donor liver transplantation (LDLT. Setting and Design: A prospective observational study. Methods: A total of 25 consecutive recipients with a MELD score between 15 and 20 were enrolled. Data were recorded at baseline (TB; anhepatic phase (TA; and post-reperfusion - 1, 5, 10 and 30 minutes. Fluid therapy was guided by corrected flow time (FTc of the TED. Packed red blood cells (RBCs were only given when hematocrit was less than 25%. Rotational thromboelastometry (ROTEM and standard laboratory tests were used to guide component blood products requirements. Results: Post-reperfusion, the COP, Cardiac Index (CI and stroke volume (SV increased significantly at all points of measurements; this was associated with a significant decrease in systemic vascular resistance (SVR ( P <.05. Immediately post-reperfusion, for 5 minutes, mean arterial blood pressure (ABP dropped significantly (P<.05, and 14 out of the 25 patients required boluses of epinephrine (10 μg to restore the mean ABP; 3 of the 14 patients required norepinephrine infusion till the end of surgery. Central venous pressure (CVP and urine output (UOP at all measures were maintained adequately with FTc-guided fluid replacement. Eight out of the 25 patients required no blood transfusion, and 4 of the 8 patients required no catecholamine support. Conclusion: TED as a sole monitor for COP was able to present significant and reliable changes in the cardiovascular status of the recipients during reperfusion, which could help to guide fluid- and drug-supportive therapy in this population of patients. This preliminary study needs to be applied on a larger scale.

  4. Relationship between myocardial T2* values and cardiac volumetric and functional parameters in β-thalassemia patients evaluated by cardiac magnetic resonance in association with serum ferritin levels

    Energy Technology Data Exchange (ETDEWEB)

    Liguori, Carlo, E-mail: c.liguori@unicampus.it [Department of Diagnostic Imaging, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy); Pitocco, Francesca, E-mail: f.pitocco@unicampus.it [Department of Diagnostic Imaging, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy); Di Giampietro, Ilenia, E-mail: i.digiampietro@unicampus.it [Department of Diagnostic Imaging, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy); Vivo, Aldo Eros de, E-mail: devivoeros@gmail.com [Department of Diagnostic Imaging, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy); Schena, Emiliano, E-mail: e.schena@unicampus.it [Unit of Measurements and Biomedical Instrumentation, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy); Cianciulli, Paolo, E-mail: CIANCIULLI.PAOLO@aslrmc.it [Thalassemia Unit, Ospedale Sant Eugenio, Piazzale dell’Umanesimo 10, 00143 Rome (Italy); Zobel, Bruno Beomonte, E-mail: b.zobel@unicampus.it [Department of Diagnostic Imaging, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy)

    2013-09-15

    Purpose: Myocardial T2* cardiovascular magnetic resonance provides a rapid and reproducible assessment of cardiac iron load in thalassemia patients. Although cardiac involvement is mainly characterized by left ventricular dysfunction caused by iron overload, little is known about right ventricular function. The aim of this study was to assess the relationship between T2* value in myocardium and left–right ventricular volumetric and functional parameters and to evaluate the existing associations between left–right ventricles volumetric and functional parameter, myocardial T2* values and blood ferritin levels. Materials and methods: A retrospective analysis of 208 patients with β-thalassemia major and thalassemia intermedia was performed (109 males and 99 females; mean age 37.7 ± 13 years; 143 thalassemia major, 65 thalassemia intermedia). Myocardial iron load was assessed by T2* measurements, and volumetric functions were analyzed using the steady state free precession sequence. Results: A significant correlation was observed between EFLV and T2* (p = 0.0001), EFRV and T2* (p = 0.0279). An inverse correlation was present between DVLV and T2* (p = 0.0468), SVLV and T2* (p = 0.0003), SVRV and T2* (p = 0.0001). There was no significant correlation between cardiac T2* and LV–RV mass indices. A significant correlation was observed between T2* and serum ferritin levels (p < 0.001) and between EFLV and serum ferritin (p < 0.05). Conclusion: Myocardial iron load assessed by T2* cardiac magnetic resonance is associated with deterioration in left–right ventricular function; this is more evident when T2* values fall below 14 ms. CMR appears to be a promising approach for cardiac risk evaluation in TM patients.

  5. Using a sensitivity study to facilitate the design of a multi-electrode array to measure six cardiac conductivity values.

    Science.gov (United States)

    Johnston, Barbara M

    2013-07-01

    When using the bidomain model to model the electrical activity of the heart, there are potentially six cardiac conductivity values involved: conductivity values in directions along and normal to the cardiac fibres with a sheet, as well as a conductivity value in the normal direction between the sheets, and these occur for both the extracellular and intracellular domains in the model. To date it has been common to assume that the two normal direction conductivity values are the same. However, recent work has demonstrated that six cardiac conductivity values, rather than four, are necessary for accurate modelling, which can then facilitate understanding of cardiovascular disease. To design a method to determine these conductivities, it is also necessary to design a suitable multi-electrode array, which can be used, in conjunction with an inversion technique, to retrieve conductivity values from measurements of potential made on the array. This work uses the results of a study, into the sensitivity of the measuring potentials to variability in the input conductivities, to facilitate the design of an array that could be used to retrieve six cardiac conductivity values, as well as fibre rotation angle. It is found that if an electrode in the array has a much lower value of potential than the other electrodes, then it tends to be much more sensitive to the input conductivities than the other electrodes. It also appears that inclusion of this type of electrode in the set of measuring electrodes is essential for accurately retrieving conductivity values. This technique is used to identify electrodes to be included in the array and using the final design it is demonstrated, using synthetic values of potential, that the six cardiac conductivity values, and the fibre rotation angle, can be retrieved very accurately.

  6. A Probe into the Mortgage Rates of Land Contract Management Rights Based on Unified Annual Output Value

    Institute of Scientific and Technical Information of China (English)

    Zhongjun; YI

    2013-01-01

    The mortgage of land contract management rights has launched a pilot project in Ningxia,Hubei,Henan,Guizhou,Chongqing and other provinces,municipalities and autonomous regions,which provides a good solution to the problem of funds for rural development and plays a huge role in promoting local rural economic development.In the mortgage financing of land contract management rights implemented in various regions,how to determine a scientific,accurate and reasonable mortgage rate of land contract management rights becomes a difficulty troubling the mortgage financing of land.On the basis of unified annual output value of land,this article uses survey method,income capitalization method,and comparison method to analyze the value of land contract management rights,and finally determine the mortgage rates of land contract management rights.

  7. Perspectives on the value of biomarkers in acute cardiac care and implications for strategic management.

    Science.gov (United States)

    Kossaify, Antoine; Garcia, Annie; Succar, Sami; Ibrahim, Antoine; Moussallem, Nicolas; Kossaify, Mikhael; Grollier, Gilles

    2013-01-01

    Biomarkers in acute cardiac care are gaining increasing interest given their clinical benefits. This study is a review of the major conditions in acute cardiac care, with a focus on biomarkers for diagnostic and prognostic assessment. Through a PubMed search, 110 relevant articles were selected. The most commonly used cardiac biomarkers (cardiac troponin, natriuretic peptides, and C-reactive protein) are presented first, followed by a description of variable acute cardiac conditions with their relevant biomarkers. In addition to the conventional use of natriuretic peptides, cardiac troponin, and C-reactive protein, other biomarkers are outlined in variable critical conditions that may be related to acute cardiac illness. These include ST2 and chromogranin A in acute dyspnea and acute heart failure, matrix metalloproteinase in acute chest pain, heart-type fatty acid binding protein in acute coronary syndrome, CD40 ligand and interleukin-6 in acute myocardial infarction, blood ammonia and lactate in cardiac arrest, as well as tumor necrosis factor-alpha in atrial fibrillation. Endothelial dysfunction, oxidative stress and inflammation are involved in the physiopathology of most cardiac diseases, whether acute or chronic. In summary, natriuretic peptides, cardiac troponin, C-reactive protein are currently the most relevant biomarkers in acute cardiac care. Point-of-care testing and multi-markers use are essential for prompt diagnostic approach and tailored strategic management.

  8. Glory & Dream of International Necktie Metropolis With Output Value of RMB M-Billion Yuan——On the Development of Shengzhou Necktie Industry

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    @@ Status of necktie industry: industrial cluster with output of RMB 10 billion Over 1,100 necktie enterprises, more than 50,000 employees and about 100,000 people living on the necktie industry; annual production of neckties over 300 million with output value of RMB 10 billion; taking up about 90% of national gross and 40% of global gross.

  9. Prevalence of nursing diagnosis of decreased cardiac output and the predictive value of defining characteristics in patients under evaluation for heart transplant Prevalencia del diagnóstico de enfermería de disminución del gasto cardíaco y valor predictivo de las características definidoras en pacientes en fase de evaluación para trasplante cardíaco Prevalência do diagnóstico de enfermagem de débito cardíaco diminuído e valor preditivo das características definidoras em pacientes em avaliação para transplante cardíaco

    Directory of Open Access Journals (Sweden)

    Lígia Neres Matos

    2012-04-01

    Full Text Available The purposes of the study were to identify the prevalence of defining characteristics (DC of decreased cardiac output (DCO in patients with cardiac insufficiency under evaluation for heart transplantation, and to ascertain the likelihood of defining characteristics being predictive factors for the existence of reduction in cardiac output. Data was obtained by retrospective documental analysis of the clinical records of right-sided heart catheterizations in 38 patients between 2004 and 2009. The results showed that 71.1% of the patients had decreased cardiac output (measured by cardiac index. The majority of the NANDA-International defining characteristics for DCO were more frequent in individuals with reduced cardiac index levels. The study emphasizes the odds ratio (OR for increased Systemic Vascular Resistance of OR=4.533, of the third heart sound with OR=3.429 and the reduced ejection fraction with OR=2.850. By obtaining the predictive values for the defining characteristics the study identifies them as diagnostic indicators of decreased cardiac output.El estudio tiene como objetivos identificar la prevalencia de las características definitorias de la disminución del gasto cardíaco (DGC en pacientes con insuficiencia cardíaca (IC en evaluación para el trasplante de corazón y ver la probabilidad de las características definitorias sean factores predictivos de la existencia de una disminución del gasto cardíaco. Los datos se obtuvieron mediante el análisis documental retrospectivo de historias clínicas de cateterismo cordiaco derecho en 38 pacientes con insuficiencia cardíaca en la evaluación para el trasplante de corazón entre 2004 y 2009. Los resultados mostraron que el 71% de los pacientes habían reducido el gasto cardíaco (medido por el índice cardíaco. La mayoría de las características definitorias de la NANDA-International para el DGC fueron más frecuentes en individuos con índice cardíaco reducido. Los aspectos m

  10. Prognostic value of coronary anatomy and myocardial innervation imaging in cardiac disease

    NARCIS (Netherlands)

    Veltman, Caroline Emma

    2016-01-01

    Over the last decade, there has been an exponential development in cardiac imaging technology. Currently, cardiac imaging plays a central role in clinical management and decision making in the diverse and growing population of patients encountered in daily cardiology practice. Important outcome-rela

  11. Singular value decomposition of optically-mapped cardiac rotors and fibrillatory activity

    Science.gov (United States)

    Rabinovitch, A.; Biton, Y.; Braunstein, D.; Friedman, M.; Aviram, I.; Yandrapalli, S.; Pandit, S. V.; Berenfeld, O.

    2015-03-01

    Our progress of understanding how cellular and structural factors contribute to arrhythmia is hampered in part because of controversies as to whether a fibrillating heart is driven by a single, several, or multiple number of sources, whether they are focal or reentrant and how to localize them. Here we demonstrate how a novel usage of the neutral singular value decomposition (SVD) method enables the extraction of the governing spatial and temporal modes of excitation from a rotor and fibrillatory waves. Those modes highlight patterns and regions of organization in the midst of the otherwise seemingly random propagating excitation waves. We apply the method to experimental models of cardiac fibrillation in rabbit hearts. We show that SVD analysis is able to enhance the classification of the heart electrical patterns into regions harboring drivers in the form of fast reentrant activity and other regions of by-standing activity. This enhancement is accomplished without any prior assumptions regarding the spatial, temporal or spectral properties of those drivers. The analysis corroborates that the dominant mode has the highest activation rate and further reveals a new feature: a transfer of modes from the driving to passive regions resulting in a partial reaction of the passive region to the driving region.

  12. Direct recording of cardiac output- and venous return-curves in the dog heart-lung preparation for a graphical analysis of the effects of cardioactive drugs.

    Science.gov (United States)

    Ishikawa, N; Taki, K; Hojo, Y; Hagino, Y; Shigei, T

    1978-09-01

    The dog heart-lung preparations were prepared. The "equilibrium point", which could be defined as the point at which the cardiac output (CO)-curve and the venous return (VR)-curve crossed, when the CO and VR were plotted against the right atrial pressure, was recorded directly by utilizing an X-Y recorder. The CO-curve was obtained, as a locus of the equilibrium point, by raising and lowering the level of blood in the venous reservoir (competence test). The meaning of the procedure was shown to increase or decrease the mean systemic pressure, and to cause the corresponding parallel shift in the VR-curve. The VR-curve was obtained by changing myocardial contractility. When heart failure was induced by pentobarbital or by chloroform, the equilibrium point shifted downwards to the right, depicting the VR-curve. During development of the failure, the slopes of CO-curves decreased gradually. Effects of cinobufagin and norepinephrine were also analyzed. Utilization of the X-Y recorder enabled us to settle the uniform experimental conditions more easily, and to follow the effects of drugs continuously on a diagram equating the CO- and VR-curves (Gyton's scheme).

  13. Reference values for the incremental shuttle walk test in patients with cardiovascular disease entering exercise-based cardiac rehabilitation.

    Science.gov (United States)

    Cardoso, Fernando M F; Almodhy, Meshal; Pepera, Garyfalia; Stasinopoulos, Dimitrios M; Sandercock, Gavin R H

    2017-01-01

    The incremental shuttle walk test (ISWT) is used to assess functional capacity of patients entering cardiac rehabilitation. Factors such as age and sex account for a proportion of the variance in test performance in healthy individuals but there are no reference values for patients with cardiovascular disease. The aim of this study was to produce reference values for the ISWT. Participants were n = 548 patients referred to outpatient cardiac rehabilitation who underwent a clinical examination and performed the ISWT. We used regression to identify predictors of performance and produced centile values using the generalised additive model for location, scale and shape model. Men walked significantly further than women (395 ± 165 vs. 269 ± 118 m; t = 9.5, P sex. Age (years) was the strongest predictor of performance in men (β = -5.9; 95% CI: -7.1 to -4.6 m) and women (β = -4.8; 95% CI: -6.3 to 3.3). Centile curves demonstrated a broadly linear decrease in expected ISWT values in males (25-85 years) and a more curvilinear trend in females. Patients entering cardiac rehabilitation present with highly heterogeneous ISWT values. Much of the variance in performance can be explained by patients' age and sex. Comparing absolute values with age-and sex-specific reference values may aid interpretation of ISWT performance during initial patient assessment at entry to cardiac rehabilitation.

  14. Echocardiographic Evaluation of Cardiac Function in Ischemic Rats: Value of M-Mode Echocardiography

    OpenAIRE

    Darbandi Azar, Amir; Tavakoli, Fatemeh; Moladoust, Hassan; Zare, Asghar; Sadeghpour, Anita

    2014-01-01

    Background: Echocardiography is a well-established diagnostic tool for a safe, reproducible and accurate evaluation of cardiac anatomy, hemodynamics and function in clinical practice. Objectives: We sought to demonstrate the efficacy and feasibility of M-mode echocardiography to evaluate cardiac structure and function in normal and MI-induced adult rats. Materials and Methods: All animal procedures were approved by the ethics committee of Tehran University of Medical Sciences and the investig...

  15. [Effects of temporary dual-chamber cardiac pacing in refractory cardiac failure].

    Science.gov (United States)

    Scanu, P; Lecluse, E; Michel, L; Bureau, G; Saloux, E; Cleron, S; Valette, B; Grollier, G; Potier, J C; Foucault, J P

    1996-12-01

    The authors studied 18 patients (15 men, 3 women) with an average age of 67 +/- 8 years with refractory cardiac failure. In order to determine the potential of pacing to raise cardiac output in severe cardiac failure. The average ejection fraction was 26 +/- 6.5%. All patients were in sinus rhythm:resting cardiac output was 3.35 l/min. Two temporary pacing catheters were positioned in the right atrium and at the apex of the right ventricle for dual-chamber mode pacing triggered by the spontaneous P waves. Changes in cardiac output were measured by Doppler echocardiography at different values of atrioventricular delay. Patients were considered to be responders if their cardiac outputs rose by 15%. In 7 patients meeting this criterion, the average increase in cardiac output was 27% (2.99 +/- 0.7 to 3.81 +/- 0.86 l/mn; p < 0.01); all had dilated cardiomyopathies with left bundle branch block and the optimal AV delay was 103 +/- 21 ms (80-140 ms); the duration of diastolic filling increased from 212 +/- 98 to 292 +/- 116 ms (p = 0.02). In the non-responding group (11 patients with an increase of cardiac output of only 3.6 +/- 0.09 to 3.9 +/- 0.92 l/mn; p < 0.01), the underlying disease process was mainly ischaemic. Two predictive factors of efficacy of dual-chamber pacing were identified: a short ventricular filling period (29 +/- 8% of the RR interval in the responders vs 44 +/- 9% in the non-responders; p < 0.01) and the presence of 1st degree atrioventricular block. Dual-chamber pacing could be a valuable method of increasing resting cardiac outputs in a selected group of patients with severe, refractory, cardiac failure.

  16. Single session of sprint interval training elicits similar cardiac output but lower oxygen uptake versus ramp exercise to exhaustion in men and women

    Science.gov (United States)

    Horn, Trevor; Roverud, Garret; Sutzko, Kandice; Browne, Melissa; Parra, Cristina; Astorino, Todd A

    2016-01-01

    Sprint interval training (SIT) elicits comparable long-term adaptations versus continuous exercise training (CEX) including increased maximal oxygen uptake (VO2max) and fat utilization. However, there is limited research examining acute hemodynamic responses to SIT. The aim of this study was to examine hemodynamic responses to low-volume SIT. Active men (n=6, VO2max = 39.8 ± 1.7 mL/kg/min) and women (n=7, VO2max = 37.3 ± 5.7 mL/kg/min) performed a ramp-based VO2max test (RAMP) to determine workload for the SIT session. Subjects returned within 1 wk and completed a session of SIT consisting of six 30-s bouts of “all-out” cycling at 130% maximal workload (Wmax) interspersed with 120 s of active recovery. Continuously during RAMP and exercise and recovery in SIT, VO2 was obtained and thoracic impedance was used to estimate heart rate (HR), stroke volume (SV), and cardiac output (CO). Results revealed no significant differences in COmax (p = 0.12, 19.7 ± 2.4 L/min vs. 20.3 ± 1.8 L/min) but lower SVmax (p = 0.004, 110.4 ± 15.7 mL vs. 119.4 ± 15.5 mL) in RAMP versus SIT. HRmax from SIT (179.0 ± 11.8 b/min) was lower (p = 0.008) versus RAMP (184.4 ± 7.9 b/min). Peak VO2 (L/min) was lower (p Sprint interval training consisting of 3 min of supramaximal exercise elicits similar CO yet lower VO2 compared to RAMP.

  17. Groundwater and stream threshold values for targeted and differentiated output based regulation of nutrient loadings to ecosystems

    Science.gov (United States)

    Hinsby, Klaus; Refsgaard, Jens Christian

    2015-04-01

    even field scale based on estimated acceptable nutrient loadings to transitional and coastal waters (or any other protected aquatic ecosystem in the river basin) according to the requirements of the EU Water Framework and Groundwater directives, and use these to monitor and plan sustainable water and land use management, e.g. by differentiated practices in farming and land use within sub-catchments. Specifically, we suggest that monitoring of the nitrogen outputs from catchments, sub-catchment and even delineated specific fields with new cost-effective monitoring systems in combination with coupled soil-groundwater-surface water models has a large potential for the development of efficient differentiated measures controlling nutrient loadings to aquatic ecosystems. Here we present initial considerations and suggestions for the development of new governance concepts targeted at differentiated output based regulations using threshold values for N in groundwater and streams derived from acceptable loadings to a small Danish estuary.

  18. Relationship between cardiac function and resting cerebral blood flow

    DEFF Research Database (Denmark)

    Henriksen, Otto M; Jensen, Lars T; Krabbe, Katja;

    2014-01-01

    Although both impaired cardiac function and reduced cerebral blood flow are associated with ageing, current knowledge of the influence of cardiac function on resting cerebral blood flow (CBF) is limited. The aim of this study was to investigate the potential effects of cardiac function on CBF. CBF...... and cardiac output were measured in 31 healthy subjects 50-75 years old using magnetic resonance imaging techniques. Mean values of CBF, cardiac output and cardiac index were 43.6 ml per 100 g min(-1), 5.5 l min(-1) and 2.7 l min(-1) m(-2), respectively, in males, and 53.4 ml per 100 g min(-1), 4.3 l min(-1......) and 2.4 l min(-1) m(-2), respectively, in females. No effects of cardiac output or cardiac index on CBF or structural signs of brain ageing were observed. However, fractional brain flow defined as the ratio of total brain flow to cardiac output was inversely correlated with cardiac index (r(2) = 0.22, P...

  19. 静脉输注氨茶碱治疗严重脓毒症的可行性%Effects of aminophylline on cardiac index,oxygenation index, urine output and APACHEⅡ in patients with sepsis

    Institute of Scientific and Technical Information of China (English)

    代冬梅; 王飞; 许汪斌; 杨磊; 谢翠英

    2013-01-01

    Objective To investigate the effects of aminophylline on cardiac index, oxygenation index and urine output in patients with sepsis. Methods Sixty APACHE Ⅱ score > 16 points patients with spesis of both sexes, aged 22 -76yr, were randomly divided into 2 groups( n = 30 each ) : aminophylline group ( group A ) and control group( group C ). Mechanical ventilation, antibiotics according to susceptibility or the sites of infection, early goal - directed therapy and low - dose steroids were administered for septic shock in both groups. Aminophylline 3mg/kg was infused iv over 30 min and followed by an infusion at 0. 4 mg/( kg·h ) for 4 days. Cardiac index, stroke volume variation and invasive arterial blood pressure were continuously monitored. Blood samples were drawn for blood gas analysis calculating oxygenation index and for determination of aminophylline serum concentration before aminophylline infusion( T0) and at 24h( T1), 48h( T2 ) and 72 h( T3 ) following aminophylline infusion. Urine output and total daily infusion were recorded at T0- T3. Results There were no significant differences in age, gender ratios, height, weight, APACHE Ⅱ scores, and total daily infusion between two groups ( P>0. 05 ). Compared with group C, there were no significant differences in the total daily infusion, cardiac index, oxygenation index and urine output before intravenous infusion of aminophylline ( P >0. 05 ). Compared with the values before intravenous infusion of aminophylline ( T0), oxygenation index and urine output increased in two groups ( P 0. 05 ), but it increased at T1 and T3( P 0. 05 ). Conclusion Intravenous infusion of aminophylline can increase urine output, oxygenation index and cardiac index in patients with sepsis.%目的 观察静脉输注氨茶碱对严重脓毒症患者氧合指数、尿量、心脏指数和APACHEII评分的影响,探讨静脉输注氨茶碱治疗脓毒症的可行性.方法 将60例APACHE 评分>16分的脓毒症患者随机分为氨茶

  20. Cardiac output in idiopathic normal pressure hydrocephalus: association with arterial blood pressure and intracranial pressure wave amplitudes and outcome of shunt surgery

    Directory of Open Access Journals (Sweden)

    Eide Per K

    2011-02-01

    Full Text Available Abstract Background In patients with idiopathic normal pressure hydrocephalus (iNPH responding to shunt surgery, we have consistently found elevated intracranial pressure (ICP wave amplitudes during diagnostic ICP monitoring prior to surgery. It remains unknown why ICP wave amplitudes are increased in these patients. Since iNPH is accompanied by a high incidence of vascular co-morbidity, a possible explanation is that there is reduced vascular compliance accompanied by elevated arterial blood pressure (ABP wave amplitudes and even altered cardiac output (CO. To investigate this possibility, the present study was undertaken to continuously monitor CO to determine if it is correlated to ABP and ICP wave amplitudes and the outcome of shunting in iNPH patients. It was specifically addressed whether the increased ICP wave amplitudes seen in iNPH shunt responders were accompanied by elevated CO and/or ABP wave amplitude levels. Methods Prospective iNPH patients (29 were clinically graded using an NPH grading scale. Continuous overnight minimally-invasive monitoring of CO and ABP was done simultaneously with ICP monitoring; the CO, ABP, and ICP parameters were parsed into 6-second time windows. Patients were assessed for shunt surgery on clinical grade, Evan's index, and ICP wave amplitude. Follow-up clinical grading was performed 12 months after surgery. Results ICP wave amplitudes but not CO or ABP wave amplitude, showed good correlation with the response to shunt treatment. The patients with high ICP wave amplitude did not have accompanying high levels of CO or ABP wave amplitude. Correlation analysis between CO and ICP wave amplitudes in individual patients showed different profiles [significantly positive in 10 (35% and significantly negative in 16 (55% of 29 recordings]. This depended on whether there was also a correlation between ABP and ICP wave amplitudes and on the average level of ICP wave amplitude. Conclusions These results gave no

  1. REGULATION OF INSTANTANEOUS POWER OUTPUT VALUE IN MAGNETRON WITH CONTINUOUS GENERATION MODE (M-105-, M-112-TYPES BEING PART OF PLASMA TECHNOLOGICAL UNIT

    Directory of Open Access Journals (Sweden)

    S. V. Bordusov

    2010-01-01

    Full Text Available The paper presents results of investigations pertaining to the possibility of regulating instantaneous power output  in a magnetron of M-105 (M-112-type by changing the capacity value of a capacitor in structure diagram for doubling voltage of high-voltage power supply on the basis of a step-up transformer operating in the saturation regime.

  2. Unusual presentation of listerial myocarditis and the diagnostic value of cardiac magnetic resonance.

    Science.gov (United States)

    Ladani, Amit P; Biswas, Abhishek; Vaghasia, Nishit; Generalovich, Thomas

    2015-06-01

    Listeria monocytogenes is an infrequent cause of bacterial myocarditis. Myocarditis without evidence of endocarditis is even rarer. Management in such cases involves early diagnosis, antibiotic therapy, and emergency treatment of arrhythmias. We report the case of a 47-year-old man who presented with features of acute ST-segment-elevation myocardial infarction complicated by ventricular tachycardia that necessitated urgent electrical cardioversion. Contrast-enhanced cardiac magnetic resonance images revealed hypertrophy, necrosis, and a mass that was determined to be an abscess caused by L. monocytogenes. Antibiotic treatment led to resolution of the listerial myocarditis. In addition to reporting our patient's case, we discuss the comparative advantages of cardiac magnetic resonance versus transthoracic echocardiography in characterizing myocarditis, upon presentation and in follow-up evaluation.

  3. Positive predictive value and impact of misdiagnosis of a heart failure diagnosis in administrative registers among patients admitted to a University Hospital cardiac care unit

    DEFF Research Database (Denmark)

    Mard, Shan; Nielsen, Finn Erland

    2010-01-01

    To evaluate the positive predictive value (PPV) of a diagnosis of heart failure (HF) in the Danish National Registry of Patients (NRP) among patients admitted to a University Hospital cardiac care unit, and to evaluate the impact of misdiagnosing HF.......To evaluate the positive predictive value (PPV) of a diagnosis of heart failure (HF) in the Danish National Registry of Patients (NRP) among patients admitted to a University Hospital cardiac care unit, and to evaluate the impact of misdiagnosing HF....

  4. Neurohormonal activation and diagnostic value of cardiac peptides in patients with suspected mild heart failure

    DEFF Research Database (Denmark)

    Mikkelsen, Kirsten V.; Bie, Peter; Møller, Jacob E.;

    2006-01-01

    BACKGROUND: Data describing activation of brain natriuretic peptide (BNP) system relative to the renin-angiotensin-aldosterone system (RAAS) are sparse in the early phase of heart failure (HF). AIMS: To compare activation of BNP system relative to RAAS hyperactivity and to assess diagnostic...... accuracy of cardiac peptides to detect any left ventricular dysfunction (LVD) in patients referred from primary care with suspected HF before institution of medical therapy. METHODS: Of 166 referred patients 150 were consecutively included (14 were excluded and two refused consent). Echocardiography...

  5. The Application of LM-BP Neural Network in the Prediction of Total Output Value of Agriculture

    Institute of Scientific and Technical Information of China (English)

    Zimin; ZHANG; Yanying; FAN; Guanping; CHEN

    2015-01-01

    Gross agricultural product is an important indication to measure the agricultural development level of a region. It would be affected by many factors,having the characteristics of non- linearity. For this reason,LM- BP neural network was put forward as the model and method for predicting gross agricultural product. Taking the indications of the sown area of crop,the output of grain,sugarcane,cassava,tea,meat,aquatic products,turpentine and camellia seed,etc. as inputs,during 2000 to 2012 in Guangxi,the gross agricultural product data from the analysis of simulation experiment show that the prediction of LM- BP neural network fits well with actual results.

  6. Infliximab reduces cardiac output in rheumatoid arthritis patients without heart failure Infliximabe reduz débito cardíaco em pacientes com artrite reumatoide sem insuficiência cardíaca

    Directory of Open Access Journals (Sweden)

    Rodrigo Cardoso Santos

    2012-12-01

    Full Text Available OBJECTIVE: Human anti-tumor necrosis factor (TNF-α monoclonal antibody (infliximab is used to treat autoimmune diseases such as rheumatoid arthritis (RA. Although the risk of worsening heart failure has been described in patients under chronic treatment, the acute cardiovascular effects of this drug are unknown in RA patients without heart failure. METHODS: 14 RA patients with normal echocardiography and no history of heart failure were evaluated during the 2-hour infliximab (3-5 mg/kg infusion period, using a noninvasive hemodynamic beat-to-beat system (Portapres. Stroke volume (SV; systolic, diastolic and mean blood pressures (SBP, DBP and MBP, respectively; cardiac output (CO; heart rate (HR; and total peripheral vascular resistance (PVR were recorded. All patients also received saline infusion instead of infliximab as a control. Significant differences in hemodynamic parameters were determined using Tuckey's test. All values were expressed as mean ± standard deviation (SD. RESULTS: Fourteen RA patients (6M/8F with mean age of 47.2 ± 8.8 years were evaluated. A significant decrease was found in cardiac output and stroke volume (7.04 ± 2.3 to 6.12 ± 2.1 l/min and 91 ± 29.0 to 83 ± 28.8 mL/beat, respectively after infliximab infusion. Although not statistically significant, a progressive increase was detected in SBP, DBP and total PVR during infusion. Saline infusion did not cause significant hemodynamic changes in the same group of RA patients. No adverse effects were observed during the infusion period. CONCLUSION: Acute infliximab administration decreased cardiac output due to low stroke volume in RA patients without heart disease. The results also demonstrated that, in spite of its negative inotropic effect, infliximab enhanced BP, probably by increasing PVR.OBJETIVO: O inibidor de fator de necrose tumoral (TNF-α infliximabe é usado no tratamento de doenças autoimunes como a artrite reumatoide (AR. Embora o risco de piora de

  7. Value of blood-pool subtraction in cardiac indium-111-labeled platelet imaging

    Energy Technology Data Exchange (ETDEWEB)

    Machac, J.; Vallabhajosula, S.; Goldman, M.E.; Goldsmith, S.J.; Palestro, C.; Strashun, A.; Vaquer, R.; Phillips, R.A.; Fuster, V. (Mt. Sinai Medical Center, New York, NY (USA))

    1989-09-01

    Blood-pool subtraction has been proposed to enhance {sup 111}In-labeled platelet imaging of intracardiac thrombi. We tested the accuracy of labeled platelet imaging, with and without blood-pool subtraction, in ten subjects with cardiac thrombi of varying age, eight with endocarditis being treated with antimicrobial therapy and ten normal controls. Imaging was performed early after labeled platelet injection (24 hr or less) and late (48 hr or more). Blood-pool subtraction was carried out. All images were graded subjectively by four experienced, blinded readers. Detection accuracy was measured by the sensitivity at three fixed levels of specificity estimated from receiver operator characteristic curve analysis and tested by three-way analysis of variance. Detection accuracy was generally improved on delayed images. Blood-pool subtraction did not improve accuracy. Although blood-pool subtraction increased detection sensitivity, this was offset by decreased specificity. For this population studied, blood-pool subtraction did not improve subjective detection of abnormal platelet deposition by 111In platelet imaging.

  8. The Value of Conventional Echocardiographic and Tissue Doppler Imaging in the Diagnosis of Cardiac Amyloidosis

    Institute of Scientific and Technical Information of China (English)

    Li ZHANG; Mingxing XIE; Xinfang WANG; Yali YANG; Junhong HUANG; Ming CHENG; Feixiang XIANG; Qing LU

    2008-01-01

    Transthoracic echocardiographic characteristics of 17 cases of cardiac amyloidosis (CA),a rare disease in China, were analyzed in order to improve the understanding of the disease. Seventeen cases of biopsy-proven CA, admitted to Wuhan Union Hospital from June 1994 to September 2008 were retrospectively reviewed. Twenty normal volunteers served as control group. Left atrial and ventricular functions and mitral inflow velocity were measured by two-dimensional, and Doppler echocardiography, and tissue Doppler imaging (TDI)-derived peak systolic wall motion velocities (Sv), peak early diastolic wall motion velocities (Ev), and peak late diastolic wall motion (Av) were measured at the septunm. Lateral, inferior and anterior comers of mitral annulus from the apical 4- and 2 chamber views. Compared with the control group, the interventricular septal thickness (IVSd), the left ventricular posterior wall (LVPWd), right ventricular transverse diameter (RVTDd) near the end of diastole and the interauricular septum thickness (IASs), left atrial anteroposterior diameter (LAADs), right atrial transverse diameter (RATDs) near the end of systole were increased significantly (all P<0.05) and left ventricular ejection fraction (LVEF) decreased (P<0.05) in the CA group.Compared with the control group, Sv, Ev at each wall and Av at almost all walls were significantly decreased in the CA group. In the CA group, Myocardial echoes of interventricular septum and free wall of left ventricle were enhanced evidently and distributed unevenly. The echoes presented as ground glass-like images, with some spotty hyper echoes. Both atria were enlarged, and LVEF decreased, with diastolic function impaired, and mild-moderate hydropericardium found in the CA group. It was concluded that echocardiography was a relatively sensitive and highly specific non-invasive method for the diagnosis of CA.

  9. 金融业总产出与不变价增加值核算探析%Accounting Gross Output and Value Added in Constant Prices of Financial Industry

    Institute of Scientific and Technical Information of China (English)

    陈维义; 李凯; 张东光

    2005-01-01

    This paper discusses the problem of the financial total output and real value added accounting method in theory, and connect it with the current accounting system. Then provide some views on improving the financial total output accounting method, especially provide concrete train of thought about improving the real total output and real value added accounting method in finance through comprehensive deposit rate index and loan rate index.

  10. The Economic Value of Korean Nuclear Power Industry in the National Economy: An Input-Output Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, M. K.; Kim, S. S.; Lee, J. H.; Kim, S. H. [Nuclear Policy Research Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    In 1978, Korea introduced the first nuclear power plant, Kori-1 unit, in parallel with the nation's industrialization policy. Thereafter, Korea has carried out a very ambitious nuclear power program and sustained a strong commitment to nuclear power development. Thus, nuclear is a prime energy source which presently meets about 30 percent of Korea's power demands. Also, Korea won a contract for APR-1400 NPPs to the UAE in 2009 which led to Korea as a significant exporter in the world nuclear market. Recently, the new government of Korea has been launching 'Creative Economy', from this perspective, the quantitative contributions of nuclear sector to the national economic growth are required to be estimated. This paper is to estimate quantitatively the economic values created by nuclear power industry in the framework of national economy. The total economic values created by nuclear power industry are estimated to be 63.6 trillion won for the study period.

  11. Sensory redundancy management: The development of a design methodology for determining threshold values through a statistical analysis of sensor output data

    Science.gov (United States)

    Scalzo, F.

    1983-01-01

    Sensor redundancy management (SRM) requires a system which will detect failures and reconstruct avionics accordingly. A probability density function to determine false alarm rates, using an algorithmic approach was generated. Microcomputer software was developed which will print out tables of values for the cummulative probability of being in the domain of failure; system reliability; and false alarm probability, given a signal is in the domain of failure. The microcomputer software was applied to the sensor output data for various AFT1 F-16 flights and sensor parameters. Practical recommendations for further research were made.

  12. Children diagnosed with congenital cardiac malformations at the national university departments of pediatric cardiology: positive predictive values of data in the Danish National Patient Registry

    Directory of Open Access Journals (Sweden)

    Peter Agergaard

    2011-02-01

    Full Text Available Peter Agergaard1, Anders Hebert2, Jesper Bjerre3, Karina Meden Sørensen4, Charlotte Olesen3, John Rosendal Østergaard31Department of Pediatrics, Viborg Hospital, Viborg, Denmark; 2Department of Pediatrics, Copenhagen University Hospital, Rigshospitalet, Denmark; 3Department of Pediatrics, Aarhus University Hospital, Skejby, Denmark; 4Department of Clinical Biochemistry and Immunology, Statens Serum Institut, Copenhagen, DenmarkIntroduction: The present study was conducted to establish the positive predictive value of congenital cardiac malformation diagnoses registered in the Danish National Patient Registry (NPR, thereby exploring whether the NPR can serve as a valid tool for epidemiologic studies of congenital cardiac malformations.Materials and methods: The study population comprised every individual born from 2000 to 2008 who was registered in the NPR with a congenital cardiac malformation diagnosis and treated at one of the two national departments of pediatric cardiology. Positive predictive values were established comparing NPR information with the clinical record of each individual.Results: A total of 2952 patients with a total of 3536 diagnoses were eligible for validation. Review of their clinical records unveiled no patient without cardiac malformation. In 98% (98%–99% of the cases, the NPR diagnosis could be found as the discharge diagnosis in the patient's clinical record, and in 90% (89%–91% of the cases the NPR diagnosis was considered a true reflection of the patient's actual malformation.Conclusions: Our study verifies that the present study population retrieved from the NPR is a valid tool for epidemiological research within the topic of congenital cardiac malformations, given that the research question is not dependent on a fully established sensitivity of the NPR. Precautions should be made regarding cardiac malformations characterized by low prevalence or poor predictive values, and the reported validity should not be

  13. Predictive value of assessing diastolic strain rate on survival in cardiac amyloidosis patients with preserved ejection fraction.

    Directory of Open Access Journals (Sweden)

    Dan Liu

    Full Text Available Since diastolic abnormalities are typical findings of cardiac amyloidosis (CA, we hypothesized that speckle-tracking-imaging (STI derived longitudinal early diastolic strain rate (LSRdias could predict outcome in CA patients with preserved left ventricular ejection fraction (LVEF >50%.Diastolic abnormalities including altered early filling are typical findings and are related to outcome in CA patients. Reduced longitudinal systolic strain (LSsys assessed by STI predicts increased mortality in CA patients. It remains unknown if LSRdias also related to outcome in these patients.Conventional echocardiography and STI were performed in 41 CA patients with preserved LVEF (25 male; mean age 65±9 years. Global and segmental LSsys and LSRdias were obtained in six LV segments from apical 4-chamber views.Nineteen (46% out of 41 CA patients died during a median of 16 months (quartiles 5-35 months follow-up. Baseline mitral annular plane systolic excursion (MAPSE, 6 ± 2 vs. 8 ± 3 mm, global LSRdias and basal-septal LSRdias were significantly lower in non-survivors than in survivors (all p < 0.05. NYHA class, number of non-cardiac organs involved, MAPSE, mid-septal LSsys, global LSRdias, basal-septal LSRdias and E/LSRdias were the univariable predictors of all-cause death. Multivariable analysis showed that number of non-cardiac organs involved (hazard ratio [HR] = 1.96, 95% confidence interval [CI] 1.17-3.26, P = 0.010, global LSRdias (HR = 7.30, 95% CI 2.08-25.65, P = 0.002, and E/LSRdias (HR = 2.98, 95% CI 1.54-5.79, P = 0.001 remained independently predictive of increased mortality risk. The prognostic performance of global LSRdias was optimal at a cutoff value of 0.85 S-1 (sensitivity 68%, specificity 67%. Global LSRdias < 0.85 S-1 predicted a 4-fold increased mortality in CA patients with preserved LVEF.STI-derived early diastolic strain rate is a powerful independent predictor of survival in CA patients with preserved LVEF.

  14. Changes in heart rate, arrhythmia frequency, and cardiac biomarker values in horses during recovery after a long-distance endurance ride.

    Science.gov (United States)

    Flethøj, Mette; Kanters, Jørgen K; Haugaard, Maria M; Pedersen, Philip J; Carstensen, Helena; Balling, Johanne D; Olsen, Lisbeth H; Buhl, Rikke

    2016-05-01

    OBJECTIVE To evaluate heart rate, heart rate variability, and arrhythmia frequency as well as changes in cardiac biomarker values and their association with heart rate in horses before and after an endurance ride. DESIGN Cross-sectional study. ANIMALS 28 Arabian horses competing in a 120- or 160-km endurance ride. PROCEDURES ECG recordings were obtained from each horse before (preride) and after (recovery) an endurance ride to evaluate changes in heart rate and the SD of normal R-R intervals (SDNN) during the initial 12 hours of recovery. Frequencies of supraventricular and ventricular premature complexes before and after the ride were evaluated. Blood samples were obtained before the ride and twice during recovery. Hematologic analyses included measurement of serum cardiac troponin I concentration and creatine kinase isoenzyme MB activity. RESULTS Heart rate was significantly increased and SDNN was decreased during the recovery versus preride period. Frequency of ventricular premature complexes increased during recovery, albeit not significantly, whereas frequency of supraventricular premature complexes was not significantly different between preride and recovery periods. Serum cardiac troponin I concentration and creatine kinase isoenzyme MB activity were significantly increased in the recovery versus preride period. No associations were identified between cardiac biomarkers and velocity, distance, or mean heart rate. CONCLUSIONS AND CLINICAL RELEVANCE Heart rate increased and SDNN decreased in horses after completion of an endurance ride. These and other cardiac changes suggested that prolonged exercise such as endurance riding might have cardiac effects in horses. Additional studies are needed to clarify the clinical relevance of the findings.

  15. Troponin not just a simple cardiac marker: prognostic significance of cardiac troponin

    Institute of Scientific and Technical Information of China (English)

    Benny Mulyanto Setiadi; LEI Han; CHANG Jing

    2009-01-01

    Objective The object of this study was to review the role of cardiac troponin as a prognostic factor in acute coronary syndrome patients of varying circumstances.Data sources The data used in this review were obtained mainly from the studies of cardiac troponin reported in pubmed from 1981 to 2006.Study selection Relevant articles on studies of cardiac troponin were selected.Results Elevated cardiac troponin in patients with ST elevation and non ST elevation myocardial infarction was associated with adverse outcomes, including a higher incidence of congestive heart failure, shock, and death. Patients with elevated cardiac troponin value seemed to benefit more from invasive strategies including a percutaneous coronary intervention and bypass surgery, but elevated cardiac troponin was also correlated with adverse outcomes, including a higher degree of failure, shock, and mortality in patients undergoing percutaneous coronary intervention; a higher degree of perioperative myocardial infarction, low cardiac output syndrome, cardiopulmonary resuscitation, and new-onset ventricular arrhythmia in patients undergoing bypass surgery were also observed. Elevated troponin after a percutaneous coronary intervention seemed to be associated with short-term adverse outcomes rather than long-term adverse outcomes, unless the elevation of the troponin post percutaneous coronary intervention was quite high (about 5 times above normal). On the contrary, elevated cardiac troponin after bypass surgery was more confusing to analyze since it happened in almost all patients. Furthermore, differences in cutoff values and time measurements in some studies add more confusion; thus, further research is warranted.Conclusions The prognostic value of cardiac troponin is demonstrated in almost all acute coronary syndrome patients. In addition to its high sensitivity and specificity, the prognostic value of cardiac troponin is another reason to make it the "golden cardiac marker' of this time.

  16. The additional value of first pass myocardial perfusion imaging during peak dose of dobutamine stress cardiac MRI for the detection of myocardial ischemia

    NARCIS (Netherlands)

    Lubbers, Daniel D.; Janssen, Caroline H. C.; Kuijpers, Dirkjan; Van Dijkman, Paul R. M.; Overbosch, Jelle; Willems, Tineke P.; Oudkerk, Matthijs

    2008-01-01

    Purpose of this study was to assess the additional value of first pass myocardial perfusion imaging during peak dose of dobutamine stress Cardiac-MR (CMR). Dobutamine Stress CMR was performed in 115 patients with an inconclusive diagnosis of myocardial ischemia on a 1.5 T system (Magnetom Avanto, Si

  17. Contrary microRNA Expression Pattern Between Fetal and Adult Cardiac Remodeling: Therapeutic Value for Heart Failure.

    Science.gov (United States)

    Yan, Hualin; Li, Yifei; Wang, Chuan; Zhang, Yi; Liu, Cong; Zhou, Kaiyu; Hua, Yimin

    2016-08-10

    microRNAs (miRNAs) belong to a class of non-coding RNAs that regulate post-transcriptional gene expression during development and disease. Growing evidence indicates abundant miRNA expression changes and their important role in cardiac hypertrophy and failure. However, the role of miRNAs in fetal cardiac remodeling is little known. Here, we investigated the altered expression of fifteen miRNAs in rat fetal cardiac remodeling compared with adult cardiac remodeling. Among fifteen tested miRNAs, eleven and five miRNAs (miR-199a-5p, miR-214-3p, miR-155-3p, miR-155-5p and miR-499-5p) are significantly differentially expressed in fetal and adult cardiac remodeling, respectively. After comparison of miRNA expression in fetal and adult cardiac remodeling, we find that miRNA expression returns to the fetal level in adult cardiac failure and is activated in advance of the adult level in fetal failure. The current study highlights the contrary expression pattern between fetal and adult cardiac remodeling and that supports a novel potential therapeutic approach to treating heart failure.

  18. Predictive Value of Brain Arrest Neurological Outcome Scale (BrANOS) on Mortality and Morbidity After Cardiac Arrest

    Science.gov (United States)

    Şahutoğlu, Cengiz; Uyar, Mehmet; Demirağ, Kubilay; İsayev, Hasan; Moral, Ali Reşat

    2016-01-01

    Objective There are several prediction scales and parameters for prognosis after a cardiac arrest. One of these scales is the brain arrest neurological outcome scale (BrANOS), which consists of duration of cardiac arrest, Glasgow Coma Scale score and Hounsfield unit measured on cranial computed tomography (CT) scan. The objective of this study is to investigate the effectiveness of BrANOS on predicting the mortality and disability after a cardiac arrest. Methods We retrospectively investigated cardiac arrest patients who were hospitalized in our intensive care unit (ICU) within a 3-year period. Inclusion criteria were age over 18 years old, survival of more than 24 hours after cardiac arrest and availability of cranial CT. We recorded the age, sex, diagnosis, duration of cardiac arrest and hospital stay, mortality, Glasgow Outcome Score (GOS) and BrANOS score. The primary endpoint of the study was to establish the relationship between mortality and BrANOS score in patients who survived for more than 24 hours after a cardiac arrest. The secondary endpoint of the study was to determine the 2-year life expectancy and GOS after cardiac arrest. Results The mean age of the patients was 57±17 years (33 females, 67 males). ICU mortality rate was 57%. The BrANOS mean score was 10.3±3.2. There was a significant difference between survivors and non-survivors in terms of the BrANOS score (8.8±3.2 vs. 11.6±2.7; p14 predicted death with 100% accuracy. All the patients without disability had a BrANOS score of <10. The BrANOS score also correlated well with GOS (p<0.001). The 2-year life expectancy rate was 31% in patients who survived more than 24 hours after a cardiac arrest. Conclusion In this study, we demonstrated that BrANOS provided reliable data for prognostic evaluation after a cardiac arrest. PMID:28058140

  19. 超声心动图对中晚孕正常胎儿心排血量及主动脉峡部血流量的研究%Research on cardiac output and blood flow of aortic isthmus of normal fetus in middle and late pregnancy by echocardiography

    Institute of Scientific and Technical Information of China (English)

    陈桂红; 张燕宏; 米杰; 张晓云; 李伟娟; 孙聪欣; 梁丽华; 刘涛; 王玮婧

    2014-01-01

    Objective To explore the changes of cardiac output and distribution with the increasing of pregnancy week in normal fetuses of middle and late pregnancy and establish the normal reference range.Methods Three hundred and thirteen normal fetuses in 20-40 pregnancy weeks underwent fetal echocardiography.The largest diameters of aortic valve,pulmonary valve,ductus arteriosus,aortic isthmus were measured respectively in the left ventricular outflow view,right ventricular outflow view,three vessels view and aortic arch longitudinal view.The blood flow spectrums of these parts were acquired and its velocity time integral (VTI) and heart rate (HR) were got by automatic envelope model.According to the formula of Q =(diameter/2)2 × 3.14 × VTI × HR,the cardiac output of left and right ventricle,the blood flow of aortic isthmus and ductus arteriosus were calculated.Results The cardiac outputs of left and right ventricle,combined cardiac output and the blood flow of aortic isthmus and ductus arteriosus of normal fetuses in middle and late pregnancy gradually increased with the increasing of gestational age and there were linear positive correlation between them.The blood flow of aortic isthmus increased with fetal weight,and there was significant correlation between them.The ratio of blood flow of aortic isthmus and ductus arteriosus decreased gradually with the increasing pregnancy week,and there was linear negative relationship between them.The ratio of blood flow of aortic isthmus and output of left ventricle and the ratio of blood flow of aortic isthmus and cardiac output were relatively constant,and there was poor correlation with gestational age.Conclusions Quantification of cardiac output and blood flow of AI can improve understanding about fetal circulation system physiology and help to identify abnormal pathological conditions,especially prompt the late morphological changes because of early abnormal flow of aortic isthmus.There was high clinical value for

  20. FloTrac/Vigileo系统在单肺通气心输出量监测中应用的探讨%Investigation of FloTrac/Vigileo in monitoring cardiac output during one lung ventilation

    Institute of Scientific and Technical Information of China (English)

    王宏宇; 苏中宏; 史宏伟; 鲍红光

    2011-01-01

    观察FloTrac/Vigileo系统在单肺通气心输出量(CO)监测中的应用效果.方法择期单肺通气手术患者17例,ASAⅡ或Ⅲ级,使用FloTrac/Vigileo系统观察CO变化,记录诱导后(T0)、单肺通气5 min(T1)、10 min(T2)、30min(T3)以及双腔管双肺通气时(T4)、关胸时(T5)的HR、MAP、心脏指数(CI)、每搏量变异度(SVV)和气道峰压(Pmax).结果 与T0时比较,T1、T5时CI明显增加(P<0.05);T1~T5时SVV均明显下降(P<0.05);T1~T3时Pmax显著增加(P<0.05).结论 FloTrac/Vigileo系统能快速、持续地监测单肺通气时CO的变化.%Objective To investigate the efficacy of FloTrac/Vigileo in monitoring cardiac output during one lung ventilatioa Methods Seventeen ASA Ⅱ or Ⅲ patients requiring one lung ventilation (OLV) were enrolled in the study. Cardiac index (CD and stroke volume variation (SVV) were recorded using FloTrac/Vigileo after anesthesia induction (T0), 5 min after (T1), 10 min after (T2), 30 min after (T3) OLV, during double-lumen-endobronchial-tube ventilation (T4) and at closing thorax (T5). HR, MAP and airway pressure were also recorded at these time points. Results Compared with T0, CI increased significantly at T1 and T5 (P<0. 05); SW decreased significantly from T1 to T5 (P<0. 05); and Pmax increased significantly from T1 to T3 (P<0. 05). Conclusion FloTrac/Vigileo can be used to rapidly and continuously monitor cardiac output during one lung ventilation continuously.

  1. Early assessment of post-operative cardiac output and causes of death in the neonates with congenital heart diseases%新生儿先天性心脏病术后早期心排血量评估及死亡原因分析

    Institute of Scientific and Technical Information of China (English)

    仇黎生; 刘锦纷; 徐志伟; 朱丽敏; 徐卓明

    2010-01-01

    analysis and calculated with the PiCCO plus system. Meanwhile, serum cardiac troponin I ( cTnl), mixed venous oxygen saturation ( SvO_2 ) and cardiopulmonary bypass (CPB) time were measured. Finally, the risk factors for surgical treatment in survivors and that associated with an increased mortality were analyzed. The association between post-operative cardiac output and the death after surgery was examined. Results Four neonates died after surgery, with a surgical mortality of 8.5%. CIvalue in the neonates [ (2.0±0.3 ) liters per minute per square meter of body surface was less than normal 2.5±0. 3. CI was associated inversely with CPB time but had a positive correlation with SvO_2. No significant difference association between CI and cTnI was observed. The value of cTnl was associated with the type of surgical procedures. Cases for which DHCA and low flow cerebral pefusion technique were used were free from neurological complications, ischemia in the lower extremities and oli-guria. The duration of cardiopulmonary bypass, urgent state of the operation and the abnormal coronary artery were associated with high mortality in the neonates after cardiac surgery. Conclusion The cardiac output of the neonates in whom cardiac pro-cedures were performed is adequate for the the oxygen supply required by the whole body though it is slightly lower than nomad after cardiac surgery. Higher mortality in the neonates during early postoperative period may be due to the complexity of the primary diseases, prolonged cardiopulmonary bypass time, residual abnormalities and severe acidosis before operation. Various techniques for CPB and that for the myocardial protection are safe and can provide an appropriate operative field.

  2. Prognostic value of cardiac time intervals measured by tissue Doppler imaging M-mode in the general population

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Mogelvang, Rasmus; Jensen, Jan Skov

    2015-01-01

    OBJECTIVE: Tissue Doppler imaging (TDI) M-mode through the mitral leaflet is an easy and precise method to estimate the cardiac time intervals. The aim was to evaluate the usability of the cardiac time intervals in predicting major cardiovascular events (MACE) in the general population. METHODS......: In a large prospective community-based study, cardiac function was evaluated in 1915 participants by both conventional echocardiography and TDI. The cardiac time intervals, including the isovolumic relaxation time (IVRT), isovolumic contraction time (IVCT) and ejection time (ET), were obtained by TDI M...... echocardiographic parameters resulted in a significant increase in the c-statistics (0.76 vs 0.75 ptime intervals that include...

  3. Predictive Value of Beat-to-Beat QT Variability Index across the Continuum of Left Ventricular Dysfunction: Competing Risks of Non-cardiac or Cardiovascular Death, and Sudden or Non-Sudden Cardiac Death

    Science.gov (United States)

    Tereshchenko, Larisa G.; Cygankiewicz, Iwona; McNitt, Scott; Vazquez, Rafael; Bayes-Genis, Antoni; Han, Lichy; Sur, Sanjoli; Couderc, Jean-Philippe; Berger, Ronald D.; de Luna, Antoni Bayes; Zareba, Wojciech

    2012-01-01

    Background The goal of this study was to determine the predictive value of beat-to-beat QT variability in heart failure (HF) patients across the continuum of left ventricular dysfunction. Methods and Results Beat-to-beat QT variability index (QTVI), heart rate variance (LogHRV), normalized QT variance (QTVN), and coherence between heart rate variability and QT variability have been measured at rest during sinus rhythm in 533 participants of the Muerte Subita en Insuficiencia Cardiaca (MUSIC) HF study (mean age 63.1±11.7; males 70.6%; LVEF >35% in 254 [48%]) and in 181 healthy participants from the Intercity Digital Electrocardiogram Alliance (IDEAL) database. During a median of 3.7 years of follow-up, 116 patients died, 52 from sudden cardiac death (SCD). In multivariate competing risk analyses, the highest QTVI quartile was associated with cardiovascular death [hazard ratio (HR) 1.67(95%CI 1.14-2.47), P=0.009] and in particular with non-sudden cardiac death [HR 2.91(1.69-5.01), P<0.001]. Elevated QTVI separated 97.5% of healthy individuals from subjects at risk for cardiovascular [HR 1.57(1.04-2.35), P=0.031], and non-sudden cardiac death in multivariate competing risk model [HR 2.58(1.13-3.78), P=0.001]. No interaction between QTVI and LVEF was found. QTVI predicted neither non-cardiac death (P=0.546) nor SCD (P=0.945). Decreased heart rate variability (HRV) rather than increased QT variability was the reason for increased QTVI in this study. Conclusions Increased QTVI due to depressed HRV predicts cardiovascular mortality and non-sudden cardiac death, but neither SCD nor excracardiac mortality in HF across the continuum of left ventricular dysfunction. Abnormally augmented QTVI separates 97.5% of healthy individuals from HF patients at risk. PMID:22730411

  4. Lactate Elevation During and After Major Cardiac Surgery in Adults: A Review of Etiology, Prognostic Value, and Management.

    Science.gov (United States)

    Andersen, Lars W

    2017-03-08

    Elevated lactate is a common occurrence after cardiac surgery. This review summarizes the literature on the complex etiology of lactate elevation during and after cardiac surgery, including considerations of oxygen delivery, oxygen utilization, increased metabolism, lactate clearance, medications and fluids, and postoperative complications. Second, the association between lactate and a variety of outcomes are described, and the prognostic role of lactate is critically assessed. Despite the fact that elevated lactate is strongly associated with many important outcomes, including postoperative complications, length of stay, and mortality, little is known about the optimal management of postoperative patients with lactate elevations. This review ends with an assessment of the limited literature on this subject.

  5. Color Tissue Doppler to Analyze Fetal Cardiac Time Intervals: Normal Values and Influence of Sample Gate Size.

    Science.gov (United States)

    Willruth, A M; Steinhard, J; Enzensberger, C; Axt-Fliedner, R; Gembruch, U; Doelle, A; Dimitriou, I; Fimmers, R; Bahlmann, F

    2016-02-04

    Purpose: To assess the time intervals of the cardiac cycle in healthy fetuses in the second and third trimester using color tissue Doppler imaging (cTDI) and to evaluate the influence of different sizes of sample gates on time interval values. Materials and Methods: Time intervals were measured from the cTDI-derived Doppler waveform using a small and large region of interest (ROI) in healthy fetuses. Results: 40 fetuses were included. The median gestational age at examination was 26 + 1 (range: 20 + 5 - 34 + 5) weeks. The median frame rate was 116/s (100 - 161/s) and the median heart rate 143 (range: 125 - 158) beats per minute (bpm). Using small and large ROIs, the second trimester right ventricular (RV) mean isovolumetric contraction times (ICTs) were 39.8 and 41.4 ms (p = 0.17), the mean ejection times (ETs) were 170.2 and 164.6 ms (p < 0.001), the mean isovolumetric relaxation times (IRTs) were 52.8 and 55.3 ms (p = 0.08), respectively. The left ventricular (LV) mean ICTs were 36.2 and 39.4 ms (p = 0.05), the mean ETs were 167.4 and 164.5 ms (p = 0.013), the mean IRTs were 53.9 and 57.1 ms (p = 0.05), respectively. The third trimester RV mean ICTs were 50.7 and 50.4 ms (p = 0.75), the mean ETs were 172.3 and 181.4 ms (p = 0.49), the mean IRTs were 50.2 and 54.6 ms (p = 0.03); the LV mean ICTs were 45.1 and 46.2 ms (p = 0.35), the mean ETs were 175.2 vs. 172.9 ms (p = 0.29), the mean IRTs were 47.1 and 50.0 ms (p = 0.01), respectively. Conclusion: Isovolumetric time intervals can be analyzed precisely and relatively independent of ROI size. In the near future, automatic time interval measurement using ultrasound systems will be feasible and the analysis of fetal myocardial function can become part of the clinical routine.

  6. Acute and Chronic Changes and Predictive Value of Tpeak-Tend for Ventricular Arrhythmia Risk in Cardiac Resynchronization Therapy Patients

    Institute of Scientific and Technical Information of China (English)

    Cong Xue; Wei Hua; Chi Cai; Li-Gang Ding; Zhi-Min Liu; Xiao-Han Fan; Yun-Zi Zhao

    2016-01-01

    Background:Prolongation of the Tpeak-Tend (TpTe) interval as a measurement of transmural dispersion of repolarization (TDR) is an independent risk factor for chronic heart failure mortality.However,the cardiac resynchronization therapy's (CRT) effect on TDR is controversial.Therefore,this study aimed to evaluate CRTs acute and chronic effects on repolarization dispersion.Furthermore,we aimed to investigate the relationship between TpTe changes and ventricular arrhythmia.Methods:The study group consisted of 101 patients treated with CRT-defibrillator (CRT-D).According to whether TpTe was shortened,patients were grouped at immediate and 1-year follow-up after CRT,respectively.The echocardiogram index and ventricular arrhythmia were observed and compared in these subgroups.Results:For all patients,TpTe slightly increased immediately after CRT-D implantation,and then decreased at the l-year follow-up (from 107 ± 23 to 110 ± 21 ms within 24 h,to 94 ± 24 ms at 1-year follow-up,F=19.366,P < 0.001).No significant difference in the left ventricular reverse remodeling and ventricular tachycardia/ventricular fibrillation (VT/VF) episodes between the TpTe immediately shortened and TpTe immediately nonshortened groups.However,patients in the TpTe at 1-year shorten had a higher rate of the left ventricular (LV) reverse remodeling (65% vs.44%,x2 =4.495,P =0.038) and less VT/VF episodes (log-rank test,x2 =10.207,P =0.001) compared with TpTe 1-year nonshortened group.TpTe immediately after CRT-D independently predicted VT/VF episodes at l-year follow-up (hazard ratio [HR],1.030;P =0.001).Conclusions:Patients with TpTe shortened at l-year after CRT had a higher rate of LV reverse remodeling and less VT/VF episodes.The acute changes of TpTe after CRT have minimal value on mechanical reverse remodeling and ventricular arrhythmia.

  7. Predictive factors related to low cardiac output syndrome following aortic valve replacement%主动脉瓣置换术后发生低心排出量综合征的预测因素探讨

    Institute of Scientific and Technical Information of China (English)

    马红; 张其霞; 李晓静; 郑晓燕

    2014-01-01

    Objective To investigate the predictive factors related to postoperative low cardiac output syndrome in pa-tients after aortic valve replacement due to aortic stenosis or regurgitation. Methods Three hundred patients with aortic valve defect due to aortic stenosis (AS, n=150) or aortic incompetence (AI, n=150), who underwent isolated aortic valve replacement were included in the study. Low cardiac output syndrome(LOS) was defined as the need for high dosages of inotropic medication, and/or intra- aortic bal oon pumping to sustain adequate hemodynamic status. Results Postoperative low cardiac output syn-drome developed in 86 patients (28.6%), including 39 patients with AS (26.0%) and 47 patients with AI (31.3%). The development of postoperative LOS were associated with the fol owing factors (odds ratio in parentheses): for AS group: advanced age (OR=4.7), obesity (OR=1.8), history of heart failure (OR=1.7), end- systolic (OR=5.5) and end- diastolic intraventricular septum thickness (OR=4.2), left atrial diameter (OR=1.6), mitral and tricuspid regurgitation (OR=1.9, 1.5) before surgery, LVEF≤50.0%(OR=5.4), left ventricular end systolic diameter (OR=1.7), left ventricular end diastolic diameter (OR=1.9) and mitral regurgitation (OR=4.1) in early postoperative period; for AI group:advanced age (OR=1.9), obesity (OR=4.8), history of heart failure (OR=1.7), LVEF≤50.0%(OR=1.8), left ventricular end- systolic (OR=4.5), end- diastolic diameters (OR=6.4), left ventricular end systolic di-ameter (OR=1.5), left ventricular end diastolic diameter(OR=1.6), and tricuspid regurgitation (OR=1.5) in preoperative period and left ventricular end- systolic (OR=4.7) and end- diastolic diameters (OR=6.1), and LVEF≤50.0% (OR=7.2) in early postoperative period. Conclusion The patients at high risk for the development of low cardiac output syndrome should be the focus of trials of new techniques of myocardial protection to effectively resuscitate the ischemic myocardium and

  8. Predictive value of interleukin-6 in post-cardiac arrest patients treated with targeted temperature management at 33 °C or 36 °C

    DEFF Research Database (Denmark)

    Bro-Jeppesen, John; Kjaergaard, Jesper; Stammet, Pascal;

    2016-01-01

    AIM: Post-cardiac arrest syndrome (PCAS) is characterized by systemic inflammation, however data on the prognostic value of inflammatory markers is sparse. We sought to investigate the importance of systemic inflammation, assessed by interleukin-6 (IL-6) in comatose survivors of out-of-hospital c......AIM: Post-cardiac arrest syndrome (PCAS) is characterized by systemic inflammation, however data on the prognostic value of inflammatory markers is sparse. We sought to investigate the importance of systemic inflammation, assessed by interleukin-6 (IL-6) in comatose survivors of out......-of-hospital cardiac arrest. METHODS: A total of 682 patients enrolled in the Target Temperature Management (TTM) trial, surviving >24h with available IL-6 data were included. IL-6 was measured on days 1, 2 and 3 after return of spontaneous circulation. Severity of PCAS was assessed daily by the Sequential Organ...... Failure Assessment score. Survival status was recorded at 30 days. RESULTS: High levels of IL-6 at day 1-3 (all p

  9. Changes in heart rate, arrhythmia frequency, and cardiac biomarker values in horses during recovery after a long-distance endurance ride

    DEFF Research Database (Denmark)

    Madsen, Mette Flethøj; Kanters, Jørgen K.; Haugaard, Maria Mathilde;

    2016-01-01

    OBJECTIVE: To evaluate heart rate, heart rate variability, and arrhythmia frequency as well as changes in cardiac biomarker values and their association with heart rate in horses before and after an endurance ride. DESIGN: Cross-sectional study. ANIMALS: 28 Arabian horses competing in a 120- or 160......-km endurance ride. PROCEDURES: ECG recordings were obtained from each horse before (preride) and after (recovery) an endurance ride to evaluate changes in heart rate and the SD of normal R-R intervals (SDNN) during the initial 12 hours of recovery. Frequencies of supraventricular and ventricular...... premature complexes before and after the ride were evaluated. Blood samples were obtained before the ride and twice during recovery. Hematologic analyses included measurement of serum cardiac troponin I concentration and creatine kinase isoenzyme MB activity. RESULTS: Heart rate was significantly increased...

  10. Cardiac Time Intervals by Tissue Doppler Imaging M-Mode: Normal Values and Association with Established Echocardiographic and Invasive Measures of Systolic and Diastolic Function.

    Directory of Open Access Journals (Sweden)

    Tor Biering-Sørensen

    Full Text Available To define normal values of the cardiac time intervals obtained by tissue Doppler imaging (TDI M-mode through the mitral valve (MV. Furthermore, to evaluate the association of the myocardial performance index (MPI obtained by TDI M-mode (MPITDI and the conventional method of obtaining MPI (MPIConv, with established echocardiographic and invasive measures of systolic and diastolic function.In a large community based population study (n = 974, where all are free of any cardiovascular disease and cardiovascular risk factors, cardiac time intervals, including isovolumic relaxation time (IVRT, isovolumic contraction time (IVCT, and ejection time (ET were obtained by TDI M-mode through the MV. IVCT/ET, IVRT/ET and the MPI ((IVRT+IVCT/ET were calculated. We also included a validation population (n = 44 of patients who underwent left heart catheterization and had the MPITDI and MPIConv measured.IVRT, IVRT/ET and MPI all increased significantly with increasing age in both genders (p<0.001 for all. IVCT, ET, IVRT/ET, and MPI differed significantly between males and females, displaying that women, in general exhibit better cardiac function. MPITDI was significantly associated with invasive (dP/dt max and echocardiographic measures of systolic (LVEF, global longitudinal strain and global strainrate s and diastolic function (e', global strainrate e(p<0.05 for all, whereas MPIConv was significantly associated with LVEF, e' and global strainrate e (p<0.05 for all.Normal values of cardiac time intervals differed between genders and deteriorated with increasing age. The MPITDI (but not MPIConv is associated with most invasive and established echocardiographic measures of systolic and diastolic function.

  11. Value of Kidney Disease Improving Global Outcomes Urine Output Criteria in Critically Ⅲ Patients: A Secondary Analysis of a Multicenter Prospective Cohort Study

    Institute of Scientific and Technical Information of China (English)

    Jun-Ping Qin; Xiang-You Yu; Chuan-Yun Qian; Shu-Sheng Li; Tie-He Qin; Er-Zhen Chen; Jian-Dong Lin

    2016-01-01

    Background:Urine output (UO) is an essential criterion of the Kidney Disease Improving Global Outcomes (KDIGO) definition and classification system for acute kidney injury (AKI),of which the diagnostic value has not been extensively studied.We aimed to determine whether AKI based on KDIGO UO criteria (KDIGOUO) could improve the diagnostic and prognostic accuracy,compared with KDIGO serum creatinine criteria (KDIGOSCr).Methods:We conducted a secondary analysis of the database of a previous study conducted by China Critical Care Clinical Trial Group (CCCCTG),which was a 2-month prospective cohort study (July 1,2009 to August 31,2009) involving 3063 patients in 22 tertiary Intensive Care Units in Mainland of China.AKI was diagnosed and classified separately based on KDIGOUO and KDIGOSCr.Hospital mortality of patients with more severe AKI classification based on KDIGOUO was compared with other patients by univariate and multivariate regression analyses.Results:The prevalence of AKI increased from 52.4% based on KDIGOSCr to 55.4% based on KDIGOSCr combined with KDIGOUO.KDIGOUO also resulted in an upgrade of AKI classification in 7.3% of patients,representing those with more severe AKI classification based on KDIGOUO.Compared with non-AKI patients or those with maximum AKI classification by KDIGOSCr,those with maximum AKI classification by KDIGOUO had a significantly higher hospital mortality of 58.4% (odds ratio [OR]:7.580,95% confidence interval [C I]:4.141-13.873,P < 0.001).In a multivariate logistic regression analysis,AKI based on KDIGOUO (OR:2.891,95% CI:1.964-4.254,P< 0.001),but not based on KDIGOSCr (OR:1.322,95% CI:0.902-1.939,P =0.152),was an independent risk factor for hospital mortality.Conclusion:UO was a criterion with additional value beyond creatinine criterion for AKI diagnosis and classification,which can help identify a group of patients with high risk of death.

  12. EVALUACIÓN ECOCARDIOGRÁFICA DEL GASTO CARDÍACO SISTÉMICO EN LA ATRESIA PULMONAR CON SEPTO INTERVENTRICULAR INTACTO / Echocardiographic evaluation of cardiac output in pulmonary atresia with intact ventricular septum

    Directory of Open Access Journals (Sweden)

    Giselle Serrano Ricardo

    2013-07-01

    hemodynamic performance, influencing cardiac output and generating potential conditions for short-term prognosis. Method: A descriptive, prospective and applied study was conducted. It included 43 patients who were referred to the William Soler Pediatric Cardiology Hospital from January 1992 to November 2011 with a diagnosis of the disease. In each subject, the profiles of eight echocardiographic variables were assessed, as well as the heart rate profile. Their level of association and mutual dependence were statistically assessed by simple regression models. Results: There are considerable variations in heart rate, in the volume index and in the ejection fraction of the patients´ left ventricle compared with those in the reference control group. Conclusions: The increased size of the atrial septal defect and the prolongation of transmitral diastasis favor left ventricular volume increment. Heart rate, the restrictive nature of the left ventricular myocardium and its ejection fraction are regulatory factors of cardiac output in this disease.

  13. The prognostic value of the QT interval and QT interval dispersion in all-cause and cardiac mortality and morbidity in a population of Danish citizens

    DEFF Research Database (Denmark)

    Elming, H; Holm, E; Jun, L;

    1998-01-01

    , adjusted for age, gender, myocardial infarct, angina pectoris, diabetes mellitus, arterial hypertension, smoking habits, serum cholesterol level, and heart rate were 2.9 for the QT interval (95% confidence interval 1.1-7.8) and 4.4 for QT interval dispersion (95% confidence interval 1.0-19-1). Fatal......AIMS: To evaluate the prognostic value of the QT interval and QT interval dispersion in total and in cardiovascular mortality, as well as in cardiac morbidity, in a general population. METHODS AND RESULTS: The QT interval was measured in all leads from a standard 12-lead ECG in a random sample...

  14. Application of peritoneal dialysis in the treatment of children with low cardiac output after cardiosurgery%腹膜透析在小儿先天性心脏病术后低心排的应用

    Institute of Scientific and Technical Information of China (English)

    王风

    2014-01-01

    Objective To investigate the effect of peritoneal dialysis in the treatment of children with low cardiac output after cardiosurgery .Methods A retrospective analysis was performed on the therapeutic effect of 12 children with low cardiac output after surgery of congenital heart disease by the early peritoneal dialysis in our hospital , 2.5%low calcium peritoneal dialysis solution was selected .The single amount of peritoneal dialysis was 15~20 ml/kg, and dialysis fluid retention time was 20~30 min.After 30 min reservation, dialysis fluid was drained for about 20 min according to the blood pressure .Peritoneal dialysis interval time was extended gradually after the urine occurred .Re-tention time of peritoneal dialysis was extended if patients were suffered from hyperlactacidemia .The frequency of di-alysis was adjusted according to the the level of serum creatinine and lactate .The blood glucose , electrolytes as well as arterial and venous blood gas was monitored , and the colloid was supplied when necessary .The peritoneal dialysis start, duration and the urine recovery time was recorded .Results The urine recovery time was 5~22 h.The appli-cation time of ventilator was 70~128 h, and the time in ICU was 5~18 d.The complications of peritoneal dialysis included catheter blockage (3 cases), hypoglycemia(3 cases), hyperglycemia(1 case) and hypokalemia (2 cases). No patients suffered from peritonitis and intestinal perforation .Two cases of tetralogy of fallot were died of severe low cardiac output and multiple organ dysfunction .Conclusion Early application of peritoneal dialysis can reduce the burden of heart , lung and kidney , maintain the stability of internal environment , and reduce mortality .%目的观察腹膜透析对小儿先天性心脏病术后的低心排治疗效果。方法回顾性分析该院12例先天性心脏病术后低心排早期治疗使用腹膜透析效果。腹透液选择百特公司2.5%低钙腹膜透析液。单次腹膜透析量15

  15. [Changes in the morphology of the normal left ventricle during the phases of isovolumic contraction and relaxation. Consequences on the calculation of the volume and cardiac output by cineangiocardiographic methods].

    Science.gov (United States)

    Nitenberg, A; Geschwind, H; Herreman, F

    1976-04-01

    It is well known that the left ventricular volume, as measured by the cineangiographic method, decreases during the phase of isometric contraction. What is more, the cardiac index and the ejection fraction measured by this method are definitely larger than those derived from dilution methods. These discrepancies can be explained by movements of the mitral valve during the phases of isometric contraction and relaxation. The systolic ejection volume (SEV) was measured by three different methods: 1. End-diastolic volume (EDV) -end-systolic volume (ESV) ; 2. EDV - pre-filling volume (PFV) ; 3. Pre-ejection volume (PEV) - ESV. It has emerged that the results given by the methods (2) and (3) correspond closely, and differ significantly from those given by method (1); they are also close to those obtained by the dilution method. This difference seems to arise from the fact that the movements of the mitral valve during the phase of isometric relaxation are diametrically opposite to those which occur during isometric contraction; thus, when the values EDV-ESV are used in the calculation of SEV, an overestimate is made because the mitral valve is not to be found in the same position within the ventricular cavity for both values.

  16. Value-Addes Tax and Shadow Economy : the Role of Input-Output Linkages (revision of CentER Discussion Paper 2013-036)

    NARCIS (Netherlands)

    Hoseini, Mohammad

    2015-01-01

    Under the VAT, formal traders report their purchases to the administration for a deduction in their VAT bill. This paper models this third-party reporting feature of the VAT in an input-output economy and quantifies it among different activities using a forward linkages index. The administration can

  17. The application of pulse indication contour cardiac output to early fluid resuscitation in patients with septic shock%脉搏轮廓法在感染性休克早期液体复苏中的运用

    Institute of Scientific and Technical Information of China (English)

    李家琼; 李茂琴; 许继元; 史载祥; 张舟; 李琳; 卢飞; 莫逊; 许艳军

    2011-01-01

    液体复苏及血管活性药应用,能更精确进行液体管理,减少盲目补液,减少机械通气时间,缩短住ICU时间.%Objective To explore the use of pulse indication contour cardiac output (PiCCO) as a guidance for fluid resuscitation and vasopressors employment in patients with septic shock in order to find out the efficacy of this resuscitation strategy in the respect of outcome of patients. Mtthod A total of 30 patients with septic shock were treated with the EDGT fluid treatment protocol as the conventional treatment group from December 2006 to June 2008; and another 26 patients were given fluid treatment under the guidance of PiCCO as PiCCO group from July 2008 to October 2009. Exclusion criteria included patients with history of heart and lung diseases, and liver and kidney dysfunction. The mean arterial blood pressure was maintained above or equal to 65mmHg in PiCCO group,and fluid resuscitation was concluded when global end-diastolic volume index reached 600~750 mL·-2 with the stroke volume variation in < 10% and without auricular fibrillation. Nor-epinephrine was administrated to adiust the systemic peripheral vascular resistance index during 1300~1500 d·s·cm-5·m-2.Dobutamine was empoyed when global ejection fraction was compromised. The options of liquid and diuretics depend upon the presence d extra-vascular lung water. Central venous oxygen saturation and the level of lactate were observed 6hours after resuscitation. The liquid equilibrium for 3 days and the dosage of vasopressors were also recorded. The rate of survival, the time taken for weaning from mechanical ventilation, the days of ICU stay and rate of intact organ function within 28 days were compared between two groups. Results The demphics of patients of two goups were similar. There were no significant difference between PiCCO and the conventional group in values of central venous oxygen saturation and lactate 6 hours after admission to ICU (P > 0.05). And 6 h and 1d

  18. THE METHOD OF DETERMINATION OF ERROR IN THE REFERENCE VALUE OF THE DOSE DURING THE LINEAR ACCELERATOR RADIATION OUTPUT CALIBRATION PROCEDURE. Part 3. The dependence of the radiation beam characteristics

    Directory of Open Access Journals (Sweden)

    E. V. Titovich

    2016-01-01

    Full Text Available To ensure the radiation protection of oncology patients is needed to provide the constancy of functional characteristics of the medical linear accelerators, which affect the accuracy of dose delivery. For this purpose, their quality control procedures are realized including calibration of radiation output of the linac, so the error in determining the dose reference value during this procedure must not exceed 2 %. The aim is to develop a methodology for determining the error in determining this value, depending on the characteristics of the radiation beam. Dosimetric measurements of Trilogy S/N 3567 linac dose distributions have been carried out for achievement of the objectives, on the basis of which dose errors depending on the dose rate value, the accuracy of the beam quality and output factors determination, the symmetry and uniformity of the radiation field, the angular dependence of the linac radiation output were obtained. It was found that the greatest impact on the value of the error has the error in the output factors determination (up to 5.26 % for both photon energy. Dose errors caused by changing dose rate during treatment were different for two photon energies, and reached 1.6 % for 6 MeV and 1.4 % for 18 MeV. Dose errors caused by inaccuracies of the beam quality determination were different for two photon energies, and reached 1.1 % for 18 MeV and –0.3 % for 6 MeV. Errors caused by the remaining of the characteristic do not exceed 1 %. Thus, there is a possibility to express the results of periodic quality control of the linear accelerator in terms of dose and use them to conduct a comprehensive assessment of the possibility of clinical use of a linear accelerator for oncology patients irradiation on the basis of the calibration of radiation output.

  19. 应用Swan-Ganz导管测定肺动脉高压犬模型肺循环阻力及心输出量的实验研究%Application of Swan-Ganz catheter to measure pulmonary vascular resistance and cardiac output of canine model with pulmonary arterial hypertension

    Institute of Scientific and Technical Information of China (English)

    林约瑟; 李淑娟; 李轩狄; 李运泉; 王慧深

    2015-01-01

    ObjectiveTo explore the value of Swan-Ganz catheter to measure pulmonary vascular resistance (PVR) and cardiac output (CO) of canine model with pulmonary arterial hypertension (PAH).MethodsSixteen Beagle dogs were randomly divided into two groups, the control group(n=8) and the pulmonary arterial hypertension group (n=8). Arterial blood was obtained to test arterial oxygen saturation. A Swan-Ganz catheter was advanced through the the right jugular vein way to the pulmonary artery and the pulmonary arterial pressure (PAP) were measured. Blood was obtained to test the pulmonary arterial oxygen saturation and plasma concentration of brain natriuretic peptide (BNP). Cardiac output and pulmonary vascular resistance were then calculated according to formula. The pulmonary arterial hypertension group were injected dehydromonocrataline 2.5 mg/kgto set up pulmonary arterial hypertension model. Hemodynamic measure was repeated after eight weeks.ResultsEight weeks after injection of dehydromonocrotaline, the pulmonary arterial systolic pressure, mean pulmonary arterial pressure of the pulmonary arterial hypertension group were significantly increased from (20.33±1.86) mmHg to (50.10±3.72) mmHg, (10.42±1.48) mmHg to (34.30±2.35) mmHg, the pulmonary arterial resistance, pulmonary vascular resistance were significantly increased from (1.10±0.24) Wood to (12.60±0.29) Wood, (2.34±0.33) Wood to (15.68±0.68) Wood, respectively, cardiac output was significantly decreased from (4.60±0.64) L/min to (2.30±0.35) L/min (P<0.05).ConclusionIt is an accurate, stable and repeatable method to apply Swan-Ganz catheter for measuring pulmonary vascular resistance and cardiac output in Beagle models with pulmonary arterial hypertension.%目的:探讨Swan-Ganz导管在肺动脉高压犬模型肺循环阻力及心输出量测定中的应用价值。方法16只比格犬随机分为2组,正常对照组(n=8)、肺动脉高压组(n=8)。穿刺动脉取血检测血氧饱和度。

  20. Value of carnitine therapy in kidney dialysis patients and effects on cardiac function from human and animal studies.

    Science.gov (United States)

    Molyneux, Rebekah; Seymour, A-M; Bhandari, Sunil

    2012-02-01

    Cardiovascular complications are the leading cause of mortality, accounting for 50% of all deaths among patients with end-stage renal disease (ESRD). The majority of these deaths are from cardiac causes. The mechanisms underlying the enhanced susceptibility to myocardial ischaemia and subsequent morbidity in ESRD remain ill-defined. Numerous metabolic derangements accompany myocardial ischaemia and reperfusion and play a pivotal role in the development of concurrent myocardial dysfunction. Carnitine plays a critical role in myocardial energy metabolism, as the transporter of long chain fatty acyl intermediates across the inner mitochondrial membrane for β oxidation and as a central regulator of carbohydrate metabolism. Myocardial carnitine is significantly depleted during ischaemia and more particularly in uraemic patients and those on dialysis therapy. Carnitine treatment has cardiovascular benefits including modulation of myocardial metabolism, reduction in necrotic cell death and infarct size, decrease in the incidence of arrhythmias and preservation of mechanical function. This review details the profile of substrate metabolism in the uraemic heart and the impact of carnitine supplementation on metabolism and function of the reperfused heart and finally the experimental and clinical evidence for carnitine replacement therapy, in particular its impact on the uraemic heart via modulation of function and energetics.

  1. Regulation of Cardiac Hypertrophy: the nuclear option

    NARCIS (Netherlands)

    D.W.D. Kuster (Diederik)

    2011-01-01

    textabstractCardiac hypertrophy is the response of the heart to an increased workload. After myocardial infarction (MI) the surviving muscle tissue has to work harder to maintain cardiac output. This sustained increase in workload leads to cardiac hypertrophy. Despite its apparent appropriateness, c

  2. 固定资产投资对畜牧业产值影响的评价研究%The Evaluation Study of Animal Husbandry Output Value Influenced by Fixed Assets Investment

    Institute of Scientific and Technical Information of China (English)

    李战江; 杨苹; 苏金梅; 孙鹏哲

    2012-01-01

    The effect model of animal husbandry output value influenced by investment in fixed assets is established based on error correction model and state-space model,and an empirical analysis for Inner Mongolia is made.The result shows that there exist both short-term and long-term balance relations between the investment in fixed assets and animal husbandry output value.%基于误差修正模型和状态空间模型,建立了固定资产投资对内蒙古畜牧业产值的影响模型,实证表明固定资产投资对内蒙古畜牧业产值分别存在长期和短期的影响.

  3. Low radiation dose non-contrast cardiac CT: is it of value in the evaluation of mechanical aortic valve

    Energy Technology Data Exchange (ETDEWEB)

    Bazeed, Mohamed Fayez (Dept. of Diagnostic Radiology, Faculty of Medicine, Mansoura Univ. (Egypt)), email: m_bazeed@yahoo.com; Moselhy, Mohamed Saleh (Cardiology Dept. Faculty of Medicine, Suez Canal Univ. (Egypt)); Rezk, Ahmad Ibrahim (Dept. of Cardiac Surgery, Faculty of Medicine, Aim Shams Univ. (Egypt)); Al-Murayeh, Mushabab Ayedh (Dept. of Cardiac Services, Armed Forces Hospitals Southern Region (Saudi Arabia))

    2012-05-15

    Background: Prosthetic bileaflet mechanical valve function has been traditionally evaluated using echocardiography and fluoroscopy. Multidetector computed tomography (MDCT) is a novel technique for cardiac evaluation. Purpose: To evaluate bileaflet mechanical aortic valves using a low-milliampere (mA), non-contrast MDCT protocol with a limited scan range. Material and Methods: Forty patients with a bileaflet mechanical aortic valve were evaluated using a non-contrast, low-mA, ECG-gated 64 MDCT protocol with a limited scan range. MDCT findings of opening and closing valve angles were correlated to fluoroscopy and echocardiography. Also, the valve visibility was evaluated on MDCT and fluoroscopy according to a 3-point grading scale. Results: The visualization score with the MDCT was significantly superior to the fluoroscopy (3 vs. 2.7). A strong correlation was noted between the opening (r = 0.82) and closing (r = 0.96) valve angles with MDCT and fluoroscopy without a statistically significant difference (P = 0.31 and 0.16, respectively). The mean effective radiation dose of the suggested protocol was 4 +- 0.5 mSv. Five valves were evaluated using transesophageal echocardiography because the valves were difficult to evaluate with transthoracic echocardiography, and all of these valves were evaluated optimally with MDCT. A high-pressure gradient was noted in nine valves, and the MDCT showed that seven of these valves inadequately opened, and two valves opened well, which resulted in patient valve mismatch. Incomplete valve closure was noted in five valves, and the echocardiography showed significant transvalvular regurgitation in all five valves. Conclusion: MDCT can provide a precise measurement of valve function and can potentially evaluate high-pressure gradients and transvalvular regurgitation

  4. Positive predictive value and impact of misdiagnosis of a heart failure diagnosis in administrative registers among patients admitted to a University Hospital cardiac care unit

    DEFF Research Database (Denmark)

    Mard, Shan; Nielsen, Finn Erland

    2010-01-01

    patients with heart failure from July 1, 2005 to June 30, 2007. Heart failure was defined in accordance with European Society of Cardiology (ESC) guidelines. The recorded diagnoses from the NRP were compared with clinical data from the medical records. RESULTS: We identified 758 patients with a diagnosis......OBJECTIVE: To evaluate the positive predictive value (PPV) of a diagnosis of heart failure (HF) in the Danish National Registry of Patients (NRP) among patients admitted to a University Hospital cardiac care unit, and to evaluate the impact of misdiagnosing HF. DESIGN: The NRP was used to identify...... of heart failure in the NRP. The PPV of a heart failure discharge diagnosis was 84.0% (95% confidence interval: 81.2-86.6). Patients with a discharge diagnosis of HF in the NRP without fulfilling the ESC criteria for HF had a better survival rate, a lower rate of rehospitalization, none were followed...

  5. Collector-Output Analysis Program

    Science.gov (United States)

    Glandorf, D. R.; Phillips, Robert F., II

    1986-01-01

    Collector-Output Analysis Program (COAP) programmer's aid for analyzing output produced by UNIVAC collector (MAP processor). COAP developed to aid in design of segmentation structures for programs with large memory requirements and numerous elements but of value in understanding relationships among components of any program. Crossreference indexes and supplemental information produced. COAP written in FORTRAN 77.

  6. Evidence towards Improved Estimation of Respiratory Muscle Effort from Diaphragm Mechanomyographic Signals with Cardiac Vibration Interference Using Sample Entropy with Fixed Tolerance Values

    Science.gov (United States)

    Sarlabous, Leonardo; Torres, Abel; Fiz, José A.; Jané, Raimon

    2014-01-01

    The analysis of amplitude parameters of the diaphragm mechanomyographic (MMGdi) signal is a non-invasive technique to assess respiratory muscle effort and to detect and quantify the severity of respiratory muscle weakness. The amplitude of the MMGdi signal is usually evaluated using the average rectified value or the root mean square of the signal. However, these estimations are greatly affected by the presence of cardiac vibration or mechanocardiographic (MCG) noise. In this study, we present a method for improving the estimation of the respiratory muscle effort from MMGdi signals that is robust to the presence of MCG. This method is based on the calculation of the sample entropy using fixed tolerance values (fSampEn), that is, with tolerance values that are not normalized by the local standard deviation of the window analyzed. The behavior of the fSampEn parameter was tested in synthesized mechanomyographic signals, with different ratios between the amplitude of the MCG and clean mechanomyographic components. As an example of application of this technique, the use of fSampEn was explored also in recorded MMGdi signals, with different inspiratory loads. The results with both synthetic and recorded signals indicate that the entropy parameter is less affected by the MCG noise, especially at low signal-to-noise ratios. Therefore, we believe that the proposed fSampEn parameter could improve estimates of respiratory muscle effort from MMGdi signals with the presence of MCG interference. PMID:24586436

  7. Application of pulse index continuous cardiac output monitoring to improve efficiency of acute heart failure care%应用脉搏指数连续心输出量监测提升急性心力衰竭护理效果

    Institute of Scientific and Technical Information of China (English)

    孙秀月; 张领; 赵书琴

    2015-01-01

    Objective To ihvestigate the effect of pulse index continuous cardiac output (PiCCO) monitoring to nursing care of acute heart failure care.Methods The clinical data of 43 acute heart failure patients were retrospectively analyzed,patients were given pulse index continuous cardiac output monitoring and care,the patient' s nursing outcomes were observed,and the intrathoracic blood volume,cardiac output and oxygen consumption before and after the intervention were compared.Results After the implementation of PiCCO and nursing intervention,43 patients had no serious complications,improved 42 cases discharged,the other 1 patient in critical condition due to old age and heart function improvement sustained no automatic discharge.Oxygen consumption,cardiac output and intrathoracic blood volume were improved after the intervention,there was a significant difference (P < 0.05) compared to the previous indicators and intervention after intervention.Conclusions Application of pulse index continuous cardiac output can effectively improve patient's clinical parameters such as cardiac output,through the implementation of appropriate care can improve symptoms and reduce complications.%目的 探讨急性心力衰竭患者护理中应用脉搏指数连续心输出量监测(PiCCO)的效果.方法 选取平顶山市第二人民医院收治的43例急性心力衰竭患者作为研究对象,收集患者的临床资料并对其做回顾性分析,对患者实施脉搏指数连续心输出量监测和护理,对患者的护理效果进行观察,并对其干预前后的胸腔内血容量、心排血量与氧耗量进行对比观察.结果 实施PiCCO和护理干预,本研究43例患者均无严重并发症产生,42例好转出院,1例由于病情危重、高龄及心功能持续无改善自动出院.患者干预后的氧耗量、心排血量与胸腔内血容量均有所改善,干预后各项指标与干预前比较差异有统计学意义(P<0.05).结论 应用脉搏指数连续心

  8. Bioimpedância transtorácica comparada à ressonância magnética na avaliação do débito cardíaco Transthoracic impedance compared to magnetic resonance imaging in the assessment of cardiac output

    Directory of Open Access Journals (Sweden)

    Humberto Villacorta Junior

    2012-12-01

    Full Text Available FUNDAMENTO: A ressonância magnética cardíaca é considerada o método padrão-ouro para o cálculo de volumes cardíacos. A bioimpedância transtorácica cardíaca avalia o débito cardíaco. Não há trabalhos que validem essa medida comparada à ressonância. OBJETIVO: Avaliar o desempenho da bioimpedância transtorácica cardíaca no cálculo do débito cardíaco, índice cardíaco e volume sistólico, utilizando a ressonância como padrão-ouro. MÉTODOS: Avaliados 31 pacientes, com média de idade de 56,7 ± 18 anos, sendo 18 (58% do sexo masculino. Foram excluídos os pacientes cuja indicação para a ressonância magnética cardíaca incluía avaliação sob estresse farmacológico. A correlação entre os métodos foi avaliada pelo coeficiente de Pearson, e a dispersão das diferenças absolutas em relação à média foi demonstrada pelo método de Bland-Altman. A concordância entre os métodos foi realizada pelo coeficiente de correlação intraclasses. RESULTADOS: A média do débito cardíaco pela bioimpedância transtorácica cardíaca e pela ressonância foi, respectivamente, 5,16 ± 0,9 e 5,13 ± 0,9 L/min. Observou-se boa correlação entre os métodos para o débito cardíaco (r = 0,79; p = 0,0001, índice cardíaco (r = 0,74; p = 0,0001 e volume sistólico (r = 0,88; p = 0,0001. A avaliação pelo gráfico de Bland-Altman mostrou pequena dispersão das diferenças em relação à média, com baixa amplitude dos intervalos de concordância. Houve boa concordância entre os dois métodos quando avaliados pelo coeficiente de correlação intraclasses, com coeficientes para débito cardíaco, índice cardíaco e volume sistólico de 0,78, 0,73 e 0,88, respectivamente (p BACKGROUND: Cardiac magnetic resonance imaging is considered the gold-standard method for the calculation of cardiac volumes. Transthoracic impedance cardiography assesses the cardiac output. No studies validating this measurement, in comparison to that obtained

  9. Bioimpedância transtorácica comparada à ressonância magnética na avaliação do débito cardíaco Transthoracic impedance compared to magnetic resonance imaging in the assessment of cardiac output

    Directory of Open Access Journals (Sweden)

    Humberto Villacorta Junior

    2012-01-01

    Full Text Available FUNDAMENTO: A ressonância magnética cardíaca é considerada o método padrão-ouro para o cálculo de volumes cardíacos. A bioimpedância transtorácica cardíaca avalia o débito cardíaco. Não há trabalhos que validem essa medida comparada à ressonância. OBJETIVO: Avaliar o desempenho da bioimpedância transtorácica cardíaca no cálculo do débito cardíaco, índice cardíaco e volume sistólico, utilizando a ressonância como padrão-ouro. MÉTODOS: Avaliados 31 pacientes, com média de idade de 56,7 ± 18 anos, sendo 18 (58% do sexo masculino. Foram excluídos os pacientes cuja indicação para a ressonância magnética cardíaca incluía avaliação sob estresse farmacológico. A correlação entre os métodos foi avaliada pelo coeficiente de Pearson, e a dispersão das diferenças absolutas em relação à média foi demonstrada pelo método de Bland-Altman. A concordância entre os métodos foi realizada pelo coeficiente de correlação intraclasses. RESULTADOS: A média do débito cardíaco pela bioimpedância transtorácica cardíaca e pela ressonância foi, respectivamente, 5,16 ± 0,9 e 5,13 ± 0,9 L/min. Observou-se boa correlação entre os métodos para o débito cardíaco (r = 0,79; p = 0,0001, índice cardíaco (r = 0,74; p = 0,0001 e volume sistólico (r = 0,88; p = 0,0001. A avaliação pelo gráfico de Bland-Altman mostrou pequena dispersão das diferenças em relação à média, com baixa amplitude dos intervalos de concordância. Houve boa concordância entre os dois métodos quando avaliados pelo coeficiente de correlação intraclasses, com coeficientes para débito cardíaco, índice cardíaco e volume sistólico de 0,78, 0,73 e 0,88, respectivamente (p BACKGROUND: Cardiac magnetic resonance imaging is considered the gold-standard method for the calculation of cardiac volumes. Transthoracic impedance cardiography assesses the cardiac output. No studies validating this measurement, in comparison to that obtained

  10. Application of pulse contour cardiac output monitoring technique in hemodynamic monitoring in critical patients%脉搏轮廓心排血量监测技术在危重病患者血流动力学监测中的应用

    Institute of Scientific and Technical Information of China (English)

    房贺; 郑兴锋; 夏照帆

    2014-01-01

    Pulse contour cardiac output (PiCCO) monitoring is a new type of invasive hemodynamic monitoring technology,which is more and more often applied in perioperative period and the patients suffering from multiple injuries,septic shock,and extensive burn.With PiCCO one is able to monitor patients' hemodynamic indexes safely,timely,accurately,and continuously to provide reference for judgment of patients' condition and proper quality and quantity of fluid administration.This technique has a good prospect in clinical application.

  11. Economic values of growth and feed efficiency for fish farming in recirculating aquaculture system with density and nitrogen output limitations: a case study with African catfish (Clarias gariepinus)

    NARCIS (Netherlands)

    Besson, M.; Komen, H.; Aubin, J.; Boer, de I.J.M.; Poelman, M.; Quillet, E.; Vancoillie, C.; Vandeputte, M.; Arendonk, van J.A.M.

    2014-01-01

    In fish farming, economic values (EV) of breeding goal traits are lacking, even though they are key parameters when defining selection objectives. The aim of this study was to develop a bioeconomic model to estimate EV of 2 traits representing production performances in fish farming: the thermal gro

  12. Prediction Model and Algorithm of Industrial Gross Output Value Based on Electric Power Consumption%基于电力消耗的行业总产值预测模型及算法研究

    Institute of Scientific and Technical Information of China (English)

    陈晔; 王国瑞; 方彦军

    2014-01-01

    在“大数据”技术背景下,获取广东省规模以上工业企业电力消耗及总产值月度数据,基于人工神经网络结构建立行业总产值预测模型,并提出一种新的带抱团行为的粒子群优化算法完成对神经网络预测模型的参数优化,进而实现各行业基于电力消耗的总产值有效预测。仿真分析表明,新的改进型带抱团行为的粒子群优化算法具有更快的收敛速度和更高的寻优精度,能够有效地优化神经网络模型参数,实现基于电力消耗的行业总产值的有效、可靠预测。%In the context of big data technology,a prediction model for industrial gross output value based on artificial neural network was built by achieving monthly data of electric power consumption and output value of industrial enterprises above Guangdong provincial designated size. Meanwhile,a kind of new particle swarm optimization with gathering behavior was proposed to finish optimization on parameters of ANN prediction model and realize effective prediction on gross value based on electric consumption of all industries. Simulation analysis indicated that the new improved PSO was provided with faster convergence speed and higher optimizing precision which was able effectively optimize parameters of ANN model and realize effective and reliable prediction on gross output value of industries based on electric power consumption.

  13. Pulse Indicator Continuous Cardiac Output for Hemodynamics Monitoring in Patients with Septic Shock%脉搏指示连续心排血量监测(PiCCO)在脓毒症休克患者血流动力学监测中的临床价值

    Institute of Scientific and Technical Information of China (English)

    伊敏; 么改琦; 朱曦; 郭向阳

    2013-01-01

    目的 探讨脉搏指示连续心排血量监测技术(pulse indicator continuous cardiac output,PiCCO)在脓毒症休克患者血流动力学监测中的临床价值. 方法 2012年1~8月,前瞻性队列研究比较常规监测(n=12)与PiCCO监测(n=19)脓毒症休克患者的血流动力学,应用PiCCO监测指导脓毒症休克患者的液体复苏、血管收缩药和正性肌力药物的使用. 结果 2组脓毒症休克患者性别、年龄、原发病、既往病史、多器官功能不全综合征(MODS)的发生和发生MODS器官数、急性生理学及慢性健康状况评分系统(APACHE)Ⅱ、脓毒症相关器官衰竭评分(SOFA)、应用去甲肾上腺素剂量和入ICU后7天总的输液量差异均无显著性,PiCCO组初始平均动脉压(MAP)明显低于常规组[(52.00±5.00)mm Hg vs.(59.58±3.42)mm Hg,t=4.603,P=0.000],而对于PiCCO组存在心功能损害的患者应用正性肌力药治疗后达到与常规组相同的MAP达标值[(68.00±2.43)mm Hg vs.(68.58±2.88)mm Hg,t=0.607,P=0.549],2组MAP达标值差异无显著性. 结论 在PiCCO监测指导下,可以对于存在心功能损害的患者应用正性肌力药物,而不是仅应用血管收缩药升高血压.%Objective To investigate the clinical value of pulse indicator continuous cardiac output ( PiCCO) in hemodynamics monitoring for patients with septic shock. Methods A prospective cohort study comparing routine hemodynamics monitoring (n = 12) and PiCCO (n = 19) for patients with septic shock were carried out from January to August 2012. The PiCCO monitor provided a continuous assessment of fluid resuscitation, vasopressors and inotropes infusion in septic shock patients. Results There were no significant difference between the two groups in sex, age, etiology of critical illness, medical history, incidence of MODS, number of MODS involved organ, APACHE Ⅱ and SOFA scores, usage of noradrenaline, and total volume of fluid infusion in a week. In the PiCCO group, the original MAP

  14. Predictive Values of N-Terminal Pro-B-Type Natriuretic Peptide and Cardiac Troponin I for Myocardial Fibrosis in Hypertrophic Obstructive Cardiomyopathy.

    Directory of Open Access Journals (Sweden)

    Changlin Zhang

    Full Text Available Both high-sensitivity cardiac troponin T and B-type natriuretic peptide are useful in detecting myocardial fibrosis, as determined by late gadolinium enhancement (LGE cardiovascular magnetic resonance (CMR, in patients with non-obstructive hypertrophic cardiomyopathy. However, their values to predict myocardial fibrosis in hypertrophic obstructive cardiomyopathy (HOCM remain unclear. We investigated the role of N-Terminal Pro-B-Type Natriuretic Peptide (NT-proBNP and cardiac troponin I (cTnI to identify LGE-CMR in patients with HOCM.Peripheral concentrations of NT-proBNP and cTnI were determined in patients with HOCM (n = 163; age = 47.2 ± 10.8 years; 38.7% females. Contrast-enhanced CMR was performed to identify and quantify myocardial fibrosis.LGE was detected in 120 of 163 patients (73.6%. Patients with LGE had significantly higher levels of NT-proBNP and cTnI than those without LGE (1386.2 [904.6-2340.8] vs. 866.6 [707.2-1875.2] pmol/L, P = 0.003; 0.024 [0.010-0.049] vs. 0.010 [0.005-0.021] ng/ml, P <0.001, respectively. The extent of LGE was positively correlated with log cTnI (r = 0.371, P <0.001 and log NT-proBNP (r = 0.211, P = 0.007. On multivariable analysis, both log cTnI and maximum wall thickness (MWT were independent predictors of the presence of LGE (OR = 3.193, P = 0.033; OR = 1.410, P < 0.001, respectively, whereas log NT-proBNP was not. According to the ROC curve analysis, combined measurements of MWT ≥21 mm and/or cTnI ≥0.025 ng/ml indicated good diagnostic performance for the presence of LGE, with specificity of 95% or sensitivity of 88%.Serum cTnI is an independent predictor useful for identifying myocardial fibrosis, while plasma NT-proBNP is only associated with myocardial fibrosis on univariate analysis. Combined measurements of serum cTnI with MWT further improve its value in detecting myocardial fibrosis in patients with HOCM.

  15. Pulse Indicator Continuous Cardiac Output for Hemodynamics Monitoring in Patients with Septic Shock%脉搏指示连续心排血量监测(PiCCO)在脓毒症休克患者血流动力学监测中的临床价值

    Institute of Scientific and Technical Information of China (English)

    陈涛

    2015-01-01

    Objective To observe and analyze patients with septic shock pulse wave indicates continuous cardiac output monitoring (Picco) clinical value, to provide a reference for future clinical use. Methods January 2013—2014 in March during outpatient sep-sis patients admitted to 40 cases for the study, depending on the admission of hemodynamic monitoring methods divided into two groups, the study group and the control group 20 cases. Two were used for routine monitoring (control group), Picco monitoring (study group) to guide clinical treatment (fluid resuscitation, inotropic drugs, vasoconstrictor drugs, etc.). Results The mean arterial pressure in the two groups of patients after treatment of the initial value and compare, P 0.05). Conclusion Picco be monitored in patients with septic shock hemodynamic parameters with good results, it is worth further study in late.%目的:观察脓毒症休克患者采用脉波指示连续心排血量监测(PiCCO)的效果,并分析其临床应用价值。方法将医院2012年1月—2014年3月期间门诊收入的脓毒症50例患者选为研究对象,按照患者就诊时血动力指标的监测方式不同分成两组:研究组25例,对照组25例。两组分别采用常规监测(对照组)、PiCCO监测(研究组)指导临床治疗(液体复苏、正性肌力药物、血管收缩药物等)。结果两组患者的平均动脉压在初始值比较(P<0.01);研究组患者入院3 d内不同时点GEDI、PPV、SVV检测值比较,组间差异有统计学意义(P<0.05)。组间在去甲肾上腺素和就诊1周输液量比较,差异无统计学意义(P>0.05)。结论脓毒症休克患者予以PiCCO监测血流动力学指标具有良好效果,值得在后期进一步研究。

  16. Adaptive Output Tracking of Driven Oscillators

    Directory of Open Access Journals (Sweden)

    Lili Diao

    2008-01-01

    of the output tracking error to an adjustable neighborhood of the origin. In addition, good approximation of the unknown nonlinearities is also achieved by incorporating a persistent exciting signal in the parameter update law. The effectiveness of the proposed method is demonstrated by an application to a cardiac conduction system modelled by two coupled driven oscillators.

  17. External cardiac compression may be harmful in some scenarios of pulseless electrical activity.

    LENUS (Irish Health Repository)

    Hogan, T S

    2012-10-01

    Pulseless electrical activity occurs when organised or semi-organised electrical activity of the heart persists but the product of systemic vascular resistance and the increase in systemic arterial flow generated by the ejection of the left venticular stroke volume is not sufficient to produce a clinically detectable pulse. Pulseless electrical activity encompasses a very heterogeneous variety of severe circulatory shock states ranging in severity from pseudo-cardiac arrest to effective cardiac arrest. Outcomes of cardiopulmonary resuscitation for pulseless electrical activity are generally poor. Impairment of cardiac filling is the limiting factor to cardiac output in many scenarios of pulseless electrical activity, including extreme vasodilatory shock states. There is no evidence that external cardiac compression can increase cardiac output when impaired cardiac filling is the limiting factor to cardiac output. If impaired cardiac filling is the limiting factor to cardiac output and the heart is effectively ejecting all the blood returning to it, then external cardiac compression can only increase cardiac output if it increases venous return and cardiac filling. Repeated cardiac compression asynchronous with the patient\\'s cardiac cycle and raised mean intrathoracic pressure due to chest compression can be expected to reduce rather than to increase cardiac filling and therefore to reduce rather than to increase cardiac output in such circumstances. The hypothesis is proposed that the performance of external cardiac compression will have zero or negative effect on cardiac output in pulseless electrical activity when impaired cardiac filling is the limiting factor to cardiac output. External cardiac compression may be both directly and indirectly harmful to significant sub-groups of patients with pulseless electrical activity. We have neither evidence nor theory to provide comfort that external cardiac compression is not harmful in many scenarios of pulseless

  18. External cardiac compression may be harmful in some scenarios of pulseless electrical activity.

    Science.gov (United States)

    Hogan, T S

    2012-10-01

    Pulseless electrical activity occurs when organised or semi-organised electrical activity of the heart persists but the product of systemic vascular resistance and the increase in systemic arterial flow generated by the ejection of the left venticular stroke volume is not sufficient to produce a clinically detectable pulse. Pulseless electrical activity encompasses a very heterogeneous variety of severe circulatory shock states ranging in severity from pseudo-cardiac arrest to effective cardiac arrest. Outcomes of cardiopulmonary resuscitation for pulseless electrical activity are generally poor. Impairment of cardiac filling is the limiting factor to cardiac output in many scenarios of pulseless electrical activity, including extreme vasodilatory shock states. There is no evidence that external cardiac compression can increase cardiac output when impaired cardiac filling is the limiting factor to cardiac output. If impaired cardiac filling is the limiting factor to cardiac output and the heart is effectively ejecting all the blood returning to it, then external cardiac compression can only increase cardiac output if it increases venous return and cardiac filling. Repeated cardiac compression asynchronous with the patient's cardiac cycle and raised mean intrathoracic pressure due to chest compression can be expected to reduce rather than to increase cardiac filling and therefore to reduce rather than to increase cardiac output in such circumstances. The hypothesis is proposed that the performance of external cardiac compression will have zero or negative effect on cardiac output in pulseless electrical activity when impaired cardiac filling is the limiting factor to cardiac output. External cardiac compression may be both directly and indirectly harmful to significant sub-groups of patients with pulseless electrical activity. We have neither evidence nor theory to provide comfort that external cardiac compression is not harmful in many scenarios of pulseless

  19. A new era for the music industry: How new technologies and the internet affect the way music is valued and have an impact on output quality

    Directory of Open Access Journals (Sweden)

    Patokos Tassos

    2008-01-01

    Full Text Available Since its early days, the Internet has been used by the music industry as a powerful marketing tool to promote artists and their products. Nevertheless, technology developments of the past ten years, and especially the ever-growing phenomenon of file sharing, have created the general impression that the Internet is responsible for a crisis within the industry, on the grounds that music piracy has become more serious than it has ever been. The purpose of this paper is to present the impact of new technologies and the Internet on the three main actors of the music industry: consumers, artists and record companies. It is claimed that the Internet has changed the way music is valued, and also, that it may have a direct effect on the quality of the music produced, as perceived by both artists and consumers alike.

  20. Consenso brasileiro de monitorização e suporte hemodinâmico - parte III: métodos alternativos de monitorização do débito cardíaco e da volemia Brazilian consensus of monitoring and hemodynamic support - part III: alternative methods for cardiac output monitoring and volemia estimation

    Directory of Open Access Journals (Sweden)

    Guilherme Schettino

    2006-03-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: A interpretação do débito cardíaco e da pré-carga como números absolutos não traz grandes informações sobre a hemodinâmica do paciente crítico. Em contrapartida, a monitorização da resposta do débito cardíaco à expansão volêmica ou suporte inotrópico é uma ferramenta muito útil na unidade de terapia intensiva, quando o paciente apresenta algum sinal de má perfusão tecidual. Apesar do CAP ser considerado como " padrão-ouro" na avaliação destes parâmetros, foram desenvolvidas tecnologias alternativas bastante confiáveis para a sua monitorização. MÉTODO: O processo de desenvolvimento de recomendações utilizou o método Delphi modificado para criar e quantificar o consenso entre os participantes. A AMIB determinou um coordenador para o consenso, o qual escolheu seis especialistas para comporem o comitê consultivo. Outros 18 peritos de diferentes regiões do país foram selecionados para completar o painel de 25 especialistas, médicos e enfermeiros. Um levantamento bibliográfico na MEDLINE de artigos na língua inglesa foi realizado no período de 1966 a 2004. RESULTADOS: Foram apresentadas recomendações referentes à análise da variação da pressão arterial durante ventilação mecânica, débito cardíaco contínuo por contorno de pulso arterial, débito cardíaco por diluição do lítio, Doppler transesofágico, bioimpedância transtorácica, ecocardiografia e reinalação parcial de gás carbônico. CONCLUSÕES: As novas e menos invasivas técnicas para medida do débito cardíaco, pré-carga e fluidoresponsividade apresentam adequada precisão e podem ser uma alternativa ao uso do CAP em pacientes graves.BACKGROUND AND OBJECTIVES: Cardiac output and preload as absolute data do not offer helpful information about the hemodynamic of critically ill patients. However, monitoring the response of these variables to volume challenge or inotropic drugs is a very useful tool in the

  1. Diagnostic value of ECG-gated multidetector computed tomography in the early phase of suspected acute myocarditis. A preliminary comparative study with cardiac MRI

    Energy Technology Data Exchange (ETDEWEB)

    Dambrin, Gregoire; Caussin, Christophe; Lancelin, Bernard; Paul, Jean F. [Centre Chirurgical Marie Lannelongue, Departments of Cardiology and Radiology, Le Plessis Robinson (France); Laissy, Jean P.; Serfaty, Jean M. [AP-HP, Hospital Bichat, Department of Radiology, Paris (France)

    2007-02-15

    The aim of the study was to determine the potential diagnostic value of contrast-enhanced echocardiogram (ECG)-gated multidetector computed tomography (MDCT) in the setting of suspected acute myocarditis compared with contrast-enhanced magnetic resonance imaging (MRI). The study group consisted of 12 consecutive patients admitted for suspected acute myocarditis less than 10 days after onset of symptoms. All patients had clinical, electrocardiographic signs, and laboratory findings consistent with the diagnosis. All patients but one (severe claustrophobia) underwent cardiac MRI using T1-weighted delayed-enhancement images after injection of gadolinium. ECG-gated MDCT was performed in all patients and included a first-pass contrast-enhanced acquisition and a delayed acquisition. MRI revealed abnormal focal or multifocal myocardial enhancement and confirmed the diagnosis in 11 patients. The first-pass MDCT acquisition showed homogenous left-ventricle contrast enhancement and absence of coronary stenosis in all patients. Delayed MDCT acquisition, performed 5 min later without reinjection of contrast medium revealed multiple areas of myocardial hyperenhancement in a focal or a multifocal pattern (six and six patients, respectively). Extent and location of hyperenhancement at MDCT correlated well with that observed at MR examination for all 11 patients evaluated by both techniques (r=0.9167, p=0.0004). These preliminary results show that ECG-gated MDCT could be a useful alternative noninvasive diagnostic test in the early phase of acute myocarditis. (orig.)

  2. Economic values of growth and feed efficiency for fish farming in recirculating aquaculture system with density and nitrogen output limitations: a case study with African catfish (Clarias gariepinus).

    Science.gov (United States)

    Besson, M; Komen, H; Aubin, J; de Boer, I J M; Poelman, M; Quillet, E; Vancoillie, C; Vandeputte, M; van Arendonk, J A M

    2014-12-01

    In fish farming, economic values (EV) of breeding goal traits are lacking, even though they are key parameters when defining selection objectives. The aim of this study was to develop a bioeconomic model to estimate EV of 2 traits representing production performances in fish farming: the thermal growth coefficient (TGC) and the feed conversion ratio (FCR). This approach was applied to a farm producing African catfish (Clarias gariepinus) in a recirculating aquaculture system (RAS). In the RAS, 2 factors could limit production level: the nitrogen treatment capacity of the biofilter or the fish density in rearing tanks at harvest. Profit calculation includes revenue from fish sales, cost of juveniles, cost of feed, cost of waste water treatment, and fixed costs. In the reference scenario, profit was modeled to zero. EV were calculated as the difference in profit per kilogram of fish between the current population mean for both traits (µt) and the next generation of selective breeding (µt+Δt) for either TGC or FCR. EV of TGC and FCR were calculated for three generations of hypothetical selection on either TGC or FCR (respectively 6.8% and 7.6% improvement per generation). The results show that changes in TGC and FCR can affect both the number of fish that can be stocked (number of batches per year and number of fish per batch) and the factor limiting production. The EV of TGC and FCR vary and depend on the limiting factors. When dissolved NH3-N is the limiting factor for both µt and µt+Δt, increasing TGC decreases the number of fish that can be stocked but increases the number of batches that can be grown. As a result, profit remains constant and EVTGC is zero. Increasing FCR, however, increases the number of fish stocked and the ratio of fish produced per kilogram of feed consumed ("economic efficiency"). The EVFCR is 0.14 €/kg of fish, and profit per kilogram of fish increases by about 10%. When density is the limiting factor for both µt and µt+Δt, the

  3. Prognostic Value of Cardiac Time Intervals by Tissue Doppler Imaging M-Mode in Patients With Acute ST-Segment-Elevation Myocardial Infarction Treated With Primary Percutaneous Coronary Intervention

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Mogelvang, Rasmus; Søgaard, Peter;

    2013-01-01

    Background- Color tissue Doppler imaging M-mode through the mitral leaflet is an easy and precise method to estimate all cardiac time intervals from 1 cardiac cycle and thereby obtain the myocardial performance index (MPI). However, the prognostic value of the cardiac time intervals and the MPI...... assessed by color tissue Doppler imaging M-mode through the mitral leaflet in patients with ST-segment-elevation myocardial infarction (MI) is unknown. Methods and Results- In total, 391 patients were admitted with an ST-segment-elevation MI, treated with primary percutaneous coronary intervention......, and examined by echocardiography a median of 2 days after the ST-segment-elevation MI. Outcome was assessed according to death (n=33), hospitalization with heart failure (n=53), or new MI (n=25). Follow-up time was a median of 25 months. The population was stratified according to tertiles of the MPI. The risk...

  4. 脉搏指示连续心排血量监测技术救治重症胰腺炎并发急性呼吸窘迫综合征患儿二例%Pulse indicator continuous cardiac output measurement-guided treatment aids two pediatric patients with severe acute pancreatitis complicated with acute respiratory distress syndrome

    Institute of Scientific and Technical Information of China (English)

    颜卫源; 王丽杰

    2014-01-01

    Objective To evaluate the clinical value of the pulse indicator continuous cardiac output (PiCCO) system in patients with severe acute pancreatitis (SAP) complicated with acute respiratory distress syndrome (ARDS).Method Two cases of SAP with ARDS were monitored using PiCCO during comprehensive management in the Pediatric Intensive Care Unit (PICU) of Shengjing Hospital,China Medical University.To guide fluid management,the cardiac index (CI) was measured to assess cardiac function,the global end-diastolic volume index (GEDVI) was used to evaluate cardiac preload,and the extravascular lung water index (EVLWI) was used to evaluate the pulmonary edema.Result Case 1 was diagnosed with type L2 acute lymphoblastic leukemia (intermediate risk) and received the sixth maintenance phases of chemotherapy this time.After a 1-week dosage of chemotherapeutic drugs (pegaspargase and mitoxantrone),he suffered SAP combined with ARDS.Except comprehensive treatment (life supporting,antibiotic,etc.) and applying continuous veno-venous hemodiafiltration (CVVHDF) to remove inflammatory mediators.PiCCO monitor was utilized to guide fluid management.During the early stage of PiCCO monitoring,the patient showed no significant manifestations of pulmonary edema in the bedside chest X-ray (bedside ultrasound showed left pleural effusion),and had an oxygenation index 223 mmHg (1 mmHg =0.133 kPa),GEDVI 450 ml/m2,and ELVWI 7 ml/kg.We increased cardiac output to increase tissue perfusion and dehydration speed of CVVHDF was set at 70 ml/h.Two hours later,GEDVI significantly increased to 600 ml/m2 and ELVWI significantly increased to 10 ml/kg,the oxygenation index declined to 155 mmHg,the bedside chest X-ray showed a significant decrease of permeability (right lung) and PEEP was adjusted to 5 cmH2O (1 cmH2O =0.098 kPa),indicating circulating overload.ARDS subsequently occurred,upon which the fluid infusion was halted,the dehydration rate of CVVHDF raised (adjusted to 100-200 ml/h).On day 3 in the

  5. Evaluation of peak voltage, irradiation time, output and half value layer in computed tomography equipment;Avaliacao da tensao de pico, tempo de irradiacao, rendimento e camada semi-redutora em equipamentos de tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Nersissian, Denise Y.; Santos, Lucas R. dos; Saito, Ricardo H. [Universidade de Sao Paulo (IEE/USP), SP (Brazil). Inst. de Eletrotecnica e Energia; Silva, Marcia C. [Hospital Albert Einstein (HAE), Sao Paulo, SP (Brazil)

    2009-07-01

    In this work, the voltage peak, the irradiation time, output and half value layer were evaluated in two multislice computed tomography equipment. These evaluations are commonly done in conventional, fluoroscopic and mammographic equipment, but not in computed tomography. The results have depicted that accuracy and reproducibility meet the 10% limit established by Portaria SVS MS 453/1998 and by Guia de Radiodiagnostico - RE 1016/2005. The half value layer is between (6.55 +- 0.31) mmAl and (7.70 +- 0.39) mmAl for 120 kVp on three bow tie filter positions. The output obtained for the isocenter position was 0.097, 0.158, 0.227 and 0.286 mGy/mAs for 80, 100, 120 e 135 kVp, respectively; being similar between two tomography equipment. Such evaluations have only been possible due to the intervention on the CT equipment, stopping the rotation of the X-ray tube inside the gantry. (author)

  6. Cardiac arrest

    Science.gov (United States)

    ... Article.jsp. Accessed June 16, 2014. Myerburg RJ, Castellanos A. Approach to cardiac arrest and life-threatening ... PA: Elsevier Saunders; 2011:chap 63. Myerburg RJ, Castellanos A. Cardiac arrest and audden aardiac death. In: ...

  7. Short-term prognostic value of perioperative coronary sinus-derived-serum cardiac troponin-I, creatine kinase-MB, lactate, pyruvate, and lactate-pyruvate ratio in adult patients undergoing open heart surgery

    Directory of Open Access Journals (Sweden)

    Ujjwal Kumar Chowdhury

    2016-01-01

    Full Text Available Objectives: To investigate the release pattern of different cardiac metabolites and biomarkers directly from the coronary sinus (CS and to establish the diagnostic discrimination limits of each marker protein and metabolites to evaluate perioperative myocardial injury in patients undergoing cardiac surgery under cardiopulmonary bypass (CPB. Patients and Methods: Sixty-eight patients undergoing first mitral and/or aortic valve replacements with/without coronary artery bypass grafting and Bentall procedure under CPB and blood cardioplegic arrest were studied. All cardiac metabolites and biomarkers were measured in serial CS-derived blood samples at pre-CPB, immediate post aortic declamping, 10 minutes post-CPB and 12 hrs post-CPB. Results: Receiver operating characteristic curve analysis of cardiac biomarkers indicated lactate-pyruvate ratio as the superior diagnostic discriminator of myocardial injury with an optimal "cut-off" value >10.8 immediately after aortic declamping (AUC, 0.92; 95% CI: 0.85-0.98. Lactate was the second best diagnostic discriminator of myocardial injury with an optimal "cut-off" value >2mmol/l at immediately after aortic declamping (AUC, 0.89; 95% CI: 0.80-0.96. Cardiac troponin-I was the third best diagnostic discriminator of myocardial injury with an optimal "cut-off" value >2.1ng/ml at immediately after aortic declamping (AUC, 0.88; 95% CI: 0.80-0.95. Creatine kinase-MB was the fourth best diagnostic discriminator of myocardial injury with an optimal "cut-off" value >58 log units/ml prior to decanulation (AUC, 0.85; 95% CI: 0.78-0.94. Conclusions: Measurable cardiac damage exists in all patients undergoing cardiac surgery under cardioplegic arrest. The degree of myocardial injury is more in patients with poor ventricular function and those requiring longer aortic clamp time. CS-derived lactate-pyruvate ratio, lactate, cTn-I served as superior diagnostic discriminators of peri-operative myocardial damage.

  8. Clinical evaluation of the accuracy of the USCOM ultrasonic cardiac output monitor in the septic shock patients%无创超声心输出量测定对急诊感染性休克患者血流动力学状态评价的临床研究

    Institute of Scientific and Technical Information of China (English)

    刘继海; 于学忠; 王仲; 朱华栋; 徐胜勇

    2011-01-01

    目的 对急诊感染性休克患者同时进行脉搏波形指示的连续心输出量(pulse indicated continuous cardiac output, PiCCO)监测技术和无创超声心输出量测定,以有创血流动力学监测的数值作为标准,对无创超声心输出量测定方法的可靠性进行评价.方法 本试验为前瞻性研究,2008-06~2009-06北京协和医院急诊科抢救室和EICU收治32例明确诊断为感染性休克的患者,对这些患者同时进行无创超声心输出量测定和PiCCO监测,对比两者在心脏指数(cardiac index, CI)这一血流动力学核心指标上的差异,以评价无创超声心输出量测定在急诊应用中的可靠性.结果 共有30例患者同时获得了满意的血流超声多普勒影像,其中男性20例,女性10例,最小年龄26岁,最大年龄89岁,另2例患者因无法获得满意的超声结果而放弃.对比结果显示,在获得满意超声多普勒影像的前提下,无创超声心输出量和PiCCO测定的CI分别为(3.89±1.61)L/(min·m2)和(4.35±1.72)L/(min·m2)(Pearson相关系数=0.97165,P<0.0001).结论 无创超声心输出量测定是一项准确、快速、安全、无创的血流动力学监测技术,比较适合急诊患者的应用.%Objective The USCOM ultrasonic cardiac output monitor ( USCOM Pty Ltd, Coffs Harbour, NSW, Australia) is a non - invasive device that determines cardiac output by continuouswave Doppler ultrasound. The aim of this study was to evaluate the accuracy of the USCOM device compared with the PiCCO ( pulse indicated continuous cardiac output) technique on the septic shock patients in Emergency Room and Emergency Intensive Care Unit in Peking Union Medical College Hospital. Methods We conducted a prospective study in Emergency Room and Emergency Intensive Care Unit in Peking Union Medical College Hospital from June lst, 2008 to May 3lst, 2009. Thirty -two patients who were diagnosed as septic shock were recruited in this study. We evaluated the USCOM monitor by

  9. Pediatric cardiac postoperative care

    Directory of Open Access Journals (Sweden)

    Auler Jr. José Otávio Costa

    2002-01-01

    Full Text Available The Heart Institute of the University of São Paulo, Medical School is a referral center for the treatment of congenital heart diseases of neonates and infants. In the recent years, the excellent surgical results obtained in our institution may be in part due to modern anesthetic care and to postoperative care based on well-structured protocols. The purpose of this article is to review unique aspects of neonate cardiovascular physiology, the impact of extracorporeal circulation on postoperative evolution, and the prescription for pharmacological support of acute cardiac dysfunction based on our cardiac unit protocols. The main causes of low cardiac output after surgical correction of heart congenital disease are reviewed, and methods of treatment and support are proposed as derived from the relevant literature and our protocols.

  10. Valuing the DoD Process Output

    Science.gov (United States)

    2005-12-01

    for companies competing in the evolving knowledge-intensive global business environment.17 KVA, as the fourth methodology for the valuation of...make all global business activities recreate how they do business. Many companies worldwide have now realized that the human asset is the most

  11. Value of the first post-transplant biopsy for predicting long-term cardiac allograft vasculopathy (CAV and graft failure in heart transplant patients.

    Directory of Open Access Journals (Sweden)

    Carlos A Labarrere

    Full Text Available BACKGROUND: Cardiac allograft vasculopathy (CAV is the principal cause of long-term graft failure following heart transplantation. Early identification of patients at risk of CAV is essential to target invasive follow-up procedures more effectively and to establish appropriate therapies. We evaluated the prognostic value of the first heart biopsy (median: 9 days post-transplant versus all biopsies obtained within the first three months for the prediction of CAV and graft failure due to CAV. METHODS AND FINDINGS: In a prospective cohort study, we developed multivariate regression models evaluating markers of atherothrombosis (fibrin, antithrombin and tissue plasminogen activator [tPA] and endothelial activation (intercellular adhesion molecule-1 in serial biopsies obtained during the first three months post-transplantation from 172 patients (median follow-up = 6.3 years; min = 0.37 years, max = 16.3 years. Presence of fibrin was the dominant predictor in first-biopsy models (Odds Ratio [OR] for one- and 10-year graft failure due to CAV = 38.70, p = 0.002, 95% CI = 4.00-374.77; and 3.99, p = 0.005, 95% CI = 1.53-10.40 and loss of tPA was predominant in three-month models (OR for one- and 10-year graft failure due to CAV = 1.81, p = 0.025, 95% CI = 1.08-3.03; and 1.31, p = 0.001, 95% CI = 1.12-1.55. First-biopsy and three-month models had similar predictive and discriminative accuracy and were comparable in their capacities to correctly classify patient outcomes, with the exception of 10-year graft failure due to CAV in which the three-month model was more predictive. Both models had particularly high negative predictive values (e.g., First-biopsy vs. three-month models: 99% vs. 100% at 1-year and 96% vs. 95% at 10-years. CONCLUSIONS: Patients with absence of fibrin in the first biopsy and persistence of normal tPA in subsequent biopsies rarely develop CAV or graft failure during the next 10 years and potentially could be monitored less invasively

  12. TECHNIQUE OF ESTIMATION OF ERROR IN THE REFERENCE VALUE OF THE DOSE DURING THE LINEAR ACCELERATOR RADIATION OUTPUT CALIBRATION PROCEDURE. Part 2. Dependence on the characteristics of collimator, optical sourse-distance indicator, treatment field, lasers and treatment couch

    Directory of Open Access Journals (Sweden)

    Y. V. Tsitovich

    2016-01-01

    Full Text Available To ensure the safety of radiation oncology patients needed to provide consistent functional characteristics of the medical linear accelerators, which affect the accuracy of dose delivery. To this end, their quality control procedures, which include the calibration of radiation output of the linac, the error in determining the dose reference value during which must not exceed 2 %, is provided. The aim is to develop a methodology for determining the error (difference between a measured value of quantity and its true value in determining this value, depending on the characteristics of the collimator, the source to surface distance pointer, lasers, radiation field and treatment table. To achieve the objectives have been carried out dosimetric measurements of Trilogy S/N 3567 linac dose distributions, on the basis of which dose errors depending on the accuracy setting the zero position of the collimator, the deviation of the collimator rotation isocenter, the sourcesurface distance pointer accuracy, field size accuracy, the accuracy of lasers and treatment table positioning were obtained. It was found that the greatest impact on the value of the error has the error in the optical SSD indication and the error in the lasers position in the plane perpendicular to the plane of incidence of the radiation beam (up to 3.64 % for the energy of 6 MV. Dose errors caused by error in the field size were different for two photon energies, and reached 2.54 % for 6 MeV and 1.33% for 18 MeV. Errors caused by the rest of the characteristic do not exceed 1 %. Thus, it is possible to express the results of periodic quality control of these devices integrated in linac in terms of dose and use them to conduct a comprehensive assessment of the possibility of clinical use of a linear accelerator for oncology patients irradiation on the basis of the calibration of radiation output in case of development of techniques that allow to analyze the influence dosimetric

  13. Effects of Different Organic Fertilizers on Growing, Yield and Output Value of‘Honghuadajinyuan’%不同有机肥对‘红花大金元’生长及产量产值的影响

    Institute of Scientific and Technical Information of China (English)

    张杨; 宗浩; 赵峰; 李义强; 肖志新; 林跃平; 张本强

    2013-01-01

    This test was carried out in Baoshan in order to provide theoretical references for the organic fertilizer applying properly. The effect of three kinds of organic fertilizers (oil cake, farm manure and straw stalk) and the different amount of application on growing, yield and output value of‘Honghuadajinyuan’was researched. The results showed that: the growth vigor was weakened with the amount of farm manure increased. Using straw stalk was not good in the prior period, but with the amount increasing, the growth vigor was enhanced after budding stage. Meanwhile the differences in growing vigor of different amount of oil cake were not significant. Compared in economical character, there were significant differences of yield between different treatments, but opposite to output value, average price and rate of first class of flue-cured tobacco. Yield and output value showed a trend of reducing with the amount of farm manure increasing, but average price and rate of first class of flue-cured tobacco increased. However as the increasing of amount of oil cake the economical characters increased at the beginning but reduced after. The effect of different amounts of straw stalk showed low yield and high average price. Compared to compound fertilizer output value of straw stalk was lower obviously. In a word, the economical characters were batter with using oil cake 150-300 kg/hm2 and using farm manure 7500- 15000 kg/hm2.%  为给保山‘红花大金元’合理施用有机肥提供理论依据,研究了菜籽饼、农家肥、秸秆3种有机肥不同施用量对‘红花大金元’生长发育和产质量的影响。结果表明:从烟株长势上看,农家肥处理随着用量的增加长势减弱;秸秆处理在前期生长长势较差,但随着生育期推进,现蕾期以后随着秸秆施用量的增加,烟株长势增强;菜籽饼处理不同用量之间烟株长势在各生育期差别不明显。从经济性状比较,处理间产量差

  14. 心率对左心功能指数、主动脉强化 CT 值及延迟时间的影响%The effect of heart rate on left cardiac function index,enhanced CT value of aorta and delay time

    Institute of Scientific and Technical Information of China (English)

    李剑; 印弘; 石明国; 张劲松; 赵宏亮; 郑敏文

    2015-01-01

    目的:探讨心率对左心功能指数、主动脉强化 CT 值和延迟时间的影响。方法:连续选择进行冠状动脉 CTA的患者74例,在对比剂注射参数相同的情况下,按照心率分为低心率组(≤75次/分)和高心率组(>75次/分)。所得数据在0%~90% R-R 间期以10%为间隔进行重组,分析心输出量、每搏输出量和射血分数,测量两组主动脉强化 CT 值和延迟时间。并对两组间的差异进行统计学分析。结果:在对比剂注射参数相同的情况下,高心率组心输出量高于低心率组(t=3.908,P <0.05),但高心率组主动脉强化 CT 值和延迟时间均低于低心率组(t =2.536,3.454,P 均<0.05)。结论:掌握不同心率下心功能指数、主动脉强化 CT 值及延迟时间的变化有助于冠状动脉 CTA 扫描中对比剂注射参数的设定,获得优良的图像质量。%Objective:The purpose of this study was to evaluate the effect of heart rate (HR)on left cardiac function index,enhanced CT value of aorta and delay time.Methods:Seventy-four consecutive patients underwent dual-source CT an-giography using the same parameters for contrast administration.Patients were divided into slow HR groups (≤75bpm) and fast HR groups (>75bpm).All of the original data were reconstructed at 0%~90% R-R interval with 10% interval and the cardiac output,stroke volume and ejection fraction were analyzed.The enhanced CT value of aorta and delay time were measured.Statistical analyses were performed between the two groups.Results:Using the same parameters for contrast administration,the cardiac output of the fast HR group was higher than that of slow HR group,with significant difference (t=3.908,P <0.05).Yet the enhanced CT value of aorta and delay time were lower in fast HR group compared with that of slow HR group (t=2.536,3.454;P <0.05).Conclusion:Well knowledge about the variation of cardiac function index

  15. Cardiac Sarcoidosis.

    Science.gov (United States)

    Birnie, David; Ha, Andrew C T; Gula, Lorne J; Chakrabarti, Santabhanu; Beanlands, Rob S B; Nery, Pablo

    2015-12-01

    Studies suggest clinically manifest cardiac involvement occurs in 5% of patients with pulmonary/systemic sarcoidosis. The principal manifestations of cardiac sarcoidosis (CS) are conduction abnormalities, ventricular arrhythmias, and heart failure. Data indicate that an 20% to 25% of patients with pulmonary/systemic sarcoidosis have asymptomatic (clinically silent) cardiac involvement. An international guideline for the diagnosis and management of CS recommends that patients be screened for cardiac involvement. Most studies suggest a benign prognosis for patients with clinically silent CS. Immunosuppression therapy is advocated for clinically manifest CS. Device therapy, with implantable cardioverter defibrillators, is recommended for some patients.

  16. The predictive value of CHADS₂ risk score in post myocardial infarction arrhythmias - a Cardiac Arrhythmias and RIsk Stratification after Myocardial infArction (CARISMA) substudy

    DEFF Research Database (Denmark)

    Ruwald, Anne-Christine Huth; Gang, Uffe; Thomsen, Poul Erik Bloch;

    2014-01-01

    of this study was to investigate if CHADS₂ score (congestive heart failure, hypertension, age ≥75 years, diabetes and previous stroke/TCI [doubled]) can be used as a risk tool for predicting cardiac arrhythmias after MI. METHODS: The study included 297 post-MI patients from the CARISMA study with left...

  17. Suggested cut-off values for vitamin D as a risk marker for total and cardiac death in patients with suspected acute coronary syndrome

    Directory of Open Access Journals (Sweden)

    Patrycja Anna Naesgaard

    2016-02-01

    Full Text Available Background: Several studies have demonstrated an association between low vitamin D levels and cardiovascular risk. Vitamin D cut off levels are still under debate. Objectives: To assess two cut-off levels, 40 nmol/L and 70 nmol/L, respectively, for vitamin D measured as 25-hydroxyvitamin D [25(OHD] in chest pain patients with suspected acute coronary syndrome.Methods: We investigated 1853 patients from coastal-Norway and inland Northern-Argentina. A similar database was used for pooling of data. 2-year follow-up data including all-cause mortality, cardiac death and sudden cardiac death in the total patient population were analyzed, applying univariate and multivariable analysis. Results: 255 patients with known vitamin D concentrations died. In the multivariable analysis, there was a decrease in total mortality above a cut-off level of 40 nmol/L and a decrease in cardiac death above a cut-off level of 70 nmol/L, [HRs of 0.66 (95% CI, 0.50 – 0.88, p = 0.004 and 0.46 (95% CI, 0.22 – 0.94, p = 0.034, respectively].Conclusion: Vitamin D cut-off levels of 40 nmol/L and 70 nmol/L, were related to total mortality and cardiac death, respectively.

  18. Predictive value of local and core laboratory echocardiographic assessment of cardiac function in patients with chronic stable angina: The ACTION study

    NARCIS (Netherlands)

    A.M. Dart (Anthony); J.E. Otterstad (Jan Erik); B.A. Kirwan (Bridget Anne); J.D. Parker (John); S. de Brouwer (Sophie); P. Poole-Wilson (Philip); J. Lubsen (Jacobus)

    2007-01-01

    textabstractAims: To evaluate the relationship between echocardiographic cardiac function and outcome in patients with stable symptomatic angina. Methods: Baseline echo left ventricular ejection fraction and volume data measured in a central laboratory was available for 7016 patients (92% of the tot

  19. Cardiac abnormalities in children with hyperthyroidism.

    Science.gov (United States)

    Lester, L A; Sodt, P C; Rich, B H; Lucky, A W; Hutcheon, N; Arcilla, R A

    1982-01-01

    The cardiac status of 18 hyperthyroid (HT) children (9 black and 9 white) was evaluated by echocardiography. Mitral regurgitation (MR) was diagnosed clinically in 33% (6 of the 9 blacks). None of the 9 white children had MR. Left ventricular end-diastolic diameter (LVEDD) and volume (LVEDV) did not differ from the predicted normal (PN) based on body surface area and heart rate, except in those with MR where increased LVEDD and LVEDV were noted (p less than 0.02). LV mass was +1.75 standard deviations (sigma) of the PN (p less than 0.01), due to increased wall thickness of LVEDV. Left ventricular output (LVO) was +0.35 sigma PN (p = ns); however, when compared to that of normal children, LVO of HT was higher (p less than 0.001) due to the increased heart rate. Enhanced left ventricular contractility was suggested by increased rate of dimensional change during ejection (peak dD/dt-syst), with a mean value of -11.39 cm/sec as compared to the normal of -9.54 cm/sec (p less than 0.01). A linear multivariate regression equation differentiated the cardiac status of HT from that of normal children. Following treatment to euthyroid state, MR disappeared in 2 and became less in 4 patients. LVO, LV mass, and peak dD/dt-syst also became less. Significant cardiac changes occur in children with hyperthyroidism, which may be reversible in part after euthyroidism is restored.

  20. Cardiac Malpositions

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Shi Joon; Im, Chung Gie; Yeon, Kyung Mo; Hasn, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1979-06-15

    Cardiac Malposition refers to any position of the heart other than a left-sided heart in a situs solitus individual. Associated cardiac malformations are so complex that even angiocardiographic and autopsy studies may not afford an accurate information. Although the terms and classifications used to describe the internal cardiac anatomy and their arterial connections in cardiac malpositions differ and tend to be confusing, common agreement exists on the need for a segmental approach to diagnosis. Authors present 18 cases of cardiac malpositions in which cardiac catheterization and angiocardiography were done at the Department of Radiology, Seoul National University Hospital between 1971 and 1979. Authors analyzed the clinical, radiographic, operative and autopsy findings with the emphasis on the angiocardiographic findings. The results are as follows: 1. Among 18 cases with cardiac malpositions, 6 cases had dextrocardia with situs inversus, 9 cases had dextrocardia with situs solitus and 3 cases had levocardia with situs inversus. 2. There was no genuine exception to visceroatrial concordance rule. 3. Associated cardiac malpositions were variable and complex with a tendency of high association of transposition and double outlet varieties with dextrocardia in situs solitus and levocardia in situs inversus. Only one in 6 cases of dextrocardia with situs inversus had pure transposition. 4. In two cases associated pulmonary atresia was found at surgery which was not predicted by angiocardiography. 5. Because many of the associated complex lesions can be corrected surgically provided the diagnosis is accurate, the selective biplane angiocardiography with or without cineradiography is essential.

  1. The predictive value of plasma B-type natriuretic peptide levels on outcome in children with pulmonary hypertension undergoing congenital heart surgery

    Directory of Open Access Journals (Sweden)

    Ayse Baysal

    2014-09-01

    Full Text Available Background and objectives: In children undergoing congenital heart surgery, plasma brain natriuretic peptide levels may have a role in development of low cardiac output syndrome that is defined as a combination of clinical findings and interventions to augment cardiac output in children with pulmonary hypertension. Methods: In a prospective observational study, fifty-one children undergoing congenital heart surgery with preoperative echocardiographic study showing pulmonary hypertension were enrolled. The plasma brain natriuretic peptide levels were collected before operation, 12, 24 and 48 h after operation. The patients enrolled into the study were divided into two groups depending on: (1 Development of LCOS which is defined as a combination of clinical findings or interventions to augment cardiac output postoperatively; (2 Determination of preoperative brain natriuretic peptide cut-off value by receiver operating curve analysis for low cardiac output syndrome. The secondary end points were: (1 duration of mechanical ventilation ≥72 h, (2 intensive care unit stay >7days, and (3 mortality. Results: The differences in preoperative and postoperative brain natriuretic peptide levels of patients with or without low cardiac output syndrome (n = 35, n = 16, respectively showed significant differences in repeated measurement time points (p = 0.0001. The preoperative brain natriuretic peptide cut-off value of 125.5 pg mL−1 was found to have the highest sensitivity of 88.9% and specificity of 96.9% in predicting low cardiac output syndrome in patients with pulmonary hypertension. A good correlation was found between preoperative plasma brain natriuretic peptide level and duration of mechanical ventilation (r = 0.67, p = 0.0001. Conclusions: In patients with pulmonary hypertension undergoing congenital heart surgery, 91% of patients with preoperative plasma brain natriuretic peptide levels above 125.5 pg mL−1 are at risk of developing low cardiac

  2. TECHNIQUE OF ESTIMATION OF ERROR IN THE REFERENCE VALUE OF THE DOSE DURING THE LINEAR ACCELERATOR RADIATION OUTPUT CALIBRATION PROCEDURE. PART 1. DEPENDANCE OF THE MECHANICAL PARAMETERS OF LINAC’S GANTRY

    Directory of Open Access Journals (Sweden)

    Y. V. Tsitovich

    2015-01-01

    Full Text Available To ensure the safety of radiation oncology patients needed to provide a consistent functional characteristics of the medical linear electron accelerators, which affect the accuracy of dose delivery. To this end, their quality control procedures, which include the calibration of radiation output of the linear accelerator, the error in determining the dose reference value during which must not exceed 2 %, is provided. The aim is to develop a methodology for determining the error in determining this value, depending on the mechanical charachteristics of the linac’s gantry. To achieve the objectives have been carried out dosimetric measurements of Trilogy S/N 3567 linac dose distributions, on the basis of which dose errors depending on the accuracy setting the zero position of the gantry and the deviation of the gantry rotation isocenter were obtained. It was found that the greatest impact on the value of the error has gantry rotation isocenter deviation in a plane perpendicular to the plane of incidence of the radiation beam (up to 3,64% for the energy of 6 MeV. Dose errors caused by tilting the gantry and its isocenter deviation in the plane of incidence of the beam were highest for 18 MeV energy and reached –0,7 % and –0,9 % respectively. Thus, it is possible to express the results of periodic quality control of the linear accelerator ganty in terms of dose and use them to conduct a comprehensive assessment of the possibility of clinical use of a linear accelerator for oncology patients irradiation in case of development of techniques that allow to analyze the influence of the rest of its technical and dosimetric parameters for error in dose.

  3. Probabilistic Output Analysis by Program Manipulation

    OpenAIRE

    Rosendahl, Mads; Kirkeby, Maja H.

    2015-01-01

    The aim of a probabilistic output analysis is to derive a probability distribution of possible output values for a program from a probability distribution of its input. We present a method for performing static output analysis, based on program transformation techniques. It generates a probability function as a possibly uncomputable expression in an intermediate language. This program is then analyzed, transformed, and approximated. The result is a closed form expression that computes an over...

  4. Value of multislice computed tomography angiography of the thorax in preparation for catheter ablation for the treatment of atrial fibrillation: The impact of unexpected cardiac and extracardiac findings on patient care

    Energy Technology Data Exchange (ETDEWEB)

    Wissner, Erik; Wellnitz, Clinton V.; Srivathsan, Komandoor; Scott, Luis R. [Mayo Clinic Arizona - Mayo Clinic Hospital, Cardiovascular Diseases, 5777 East Mayo Boulevard, Phoenix, AZ 85054 (United States); Altemose, Gregory T. [Mayo Clinic Arizona - Mayo Clinic Hospital, Cardiovascular Diseases, 5777 East Mayo Boulevard, Phoenix, AZ 85054 (United States)], E-mail: altemose.gregory@mayo.edu

    2009-11-15

    Objective: In patients referred for catheter ablation for the treatment of atrial fibrillation, multislice computed tomography angiography of the thorax is routinely performed to assess pulmonary vein anatomy. We sought to investigate the incidence of unexpected cardiac and extracardiac findings in this select patient population and to establish how these findings influence subsequent patient care. Methods: Ninety-five patients (mean age 62 {+-} 10 years, 35% female) referred to our institution for ablation therapy for atrial fibrillation between July 2003 and October 2007 underwent multislice computed tomography angiography of the thorax. Radiologists interpreted all images. Need for additional testing, consultation and eventual diagnosis were assessed by electronic record review. Results: A total of 83 (5 cardiac, 78 extracardiac) unexpected findings were observed in 50/95 (53%) of patients. The findings prompted 23 additional tests (5 cardiac, 18 noncardiac) in 15/95 (16%) of patients and 8 subsequent referrals in 7/95 (7%) patients. In 6 patients the findings significantly altered future patient care and resulted in postponement of ablation therapy in 4 patients. In 2 patients, extracardiac findings (pulmonary emboli and adenocarcinoma of the lung) were of potentially life-saving consequence. Conclusions: In patients undergoing multislice computed tomography angiography of the thorax in anticipation of planned catheter ablation therapy for the treatment of atrial fibrillation, unexpected findings are common and of potentially significant value. In comparison, there is a higher prevalence of unexpected extracardiac, rather than cardiac findings. Further investigation of these findings may lead to postponement of ablation therapy, but may also be of potentially lifesaving consequence.

  5. Exercise efficiency of low power output cycling.

    Science.gov (United States)

    Reger, M; Peterman, J E; Kram, R; Byrnes, W C

    2013-12-01

    Exercise efficiency at low power outputs, energetically comparable to daily living activities, can be influenced by homeostatic perturbations (e.g., weight gain/loss). However, an appropriate efficiency calculation for low power outputs used in these studies has not been determined. Fifteen active subjects (seven females, eight males) performed 14, 5-min cycling trials: two types of seated rest (cranks vertical and horizontal), passive (motor-driven) cycling, no-chain cycling, no-load cycling, cycling at low (10, 20, 30, 40 W), and moderate (50, 60, 80, 100, 120 W) power outputs. Mean delta efficiency was 57% for low power outputs compared to 41.3% for moderate power outputs. Means for gross (3.6%) and net (5.7%) efficiencies were low at the lowest power output. At low power outputs, delta and work efficiency values exceeded theoretical values. In conclusion, at low power outputs, none of the common exercise efficiency calculations gave values comparable to theoretical muscle efficiency. However, gross efficiency and the slope and intercept of the metabolic power vs mechanical power output regression provide insights that are still valuable when studying homeostatic perturbations.

  6. Cardiac cameras.

    Science.gov (United States)

    Travin, Mark I

    2011-05-01

    Cardiac imaging with radiotracers plays an important role in patient evaluation, and the development of suitable imaging instruments has been crucial. While initially performed with the rectilinear scanner that slowly transmitted, in a row-by-row fashion, cardiac count distributions onto various printing media, the Anger scintillation camera allowed electronic determination of tracer energies and of the distribution of radioactive counts in 2D space. Increased sophistication of cardiac cameras and development of powerful computers to analyze, display, and quantify data has been essential to making radionuclide cardiac imaging a key component of the cardiac work-up. Newer processing algorithms and solid state cameras, fundamentally different from the Anger camera, show promise to provide higher counting efficiency and resolution, leading to better image quality, more patient comfort and potentially lower radiation exposure. While the focus has been on myocardial perfusion imaging with single-photon emission computed tomography, increased use of positron emission tomography is broadening the field to include molecular imaging of the myocardium and of the coronary vasculature. Further advances may require integrating cardiac nuclear cameras with other imaging devices, ie, hybrid imaging cameras. The goal is to image the heart and its physiological processes as accurately as possible, to prevent and cure disease processes.

  7. High-output heart failure in a newborn.

    Science.gov (United States)

    Mascarenhas, Maria Inês; Moniz, Marta; Ferreira, Sofia; Goulão, Augusto; Barroso, Rosalina

    2012-07-10

    High-output cardiac failure is rare in newborns. Emergent diagnosis and management of this pathology is crucial. We report the case of a child, currently 12-months old; obstetric background is non-contributory. Clinic observation on D1 was normal except for the presence of a systolic cardiac murmur; cardiological evaluation revealed mild ventricular dysfunction of the right ventricle. On the third day of life, she developed cardiac failure with gallop rhythm, hepatomegaly and a murmur in the anterior fontanel; an echocardiogram confirmed clinic aggravation with biventricular dysfunction and right cavities and superior vena cava dilatation. The cranial MRI confirmed the presence of a pial arteriovenous malformation (AVM) involving the anterior and middle cerebral arteries with an associated fronto-parietal ischaemic lesion. The infant underwent embolisations of AVM with successful flow reduction and cardiac failure improvement. The multidisciplinary follow-up showed no cardiac dysfunction or permanent lesions but confirmed a severe psycho-motor delay and left hemiparesia.

  8. Diagnosis and predictive value of NT-proBNP in cardiac insufficiency after acute myocardial infarction%NT-proBNP对急性心肌梗死后心功能不全的诊断及预测价值

    Institute of Scientific and Technical Information of China (English)

    胡光振

    2014-01-01

    Objective to study the diagnosis and predictive value of nt- proBnP in cardiac insufficiency after acute myocardial infarction.Methods 96 cases of incipient acute myocardial infarction patients selected were analyzed and the patients' Killip classification of heart function within 24 h were recorded. and plasma nt - proBnP concentration were measured.Results NT-proBNP concentration increased with the rising grade according to the Killip classiifcation for cardiac function, and the level of nt- proBnP and lnnt- proBnP increased with heart function declining, the difference was statistically signiifcant (P<0.01).Conclusion The concentration of plasma NT-proBNP increased signiifcantly in high risk patients after acute myocardial infarction with cardiac insufifciency, and it has a signiifcant association with acute cardiac Killip classiifcation. Therefore, NT-proBNP can be used in diagnosis and prediction in patients with cardiac insufifciency after acute myocardial infarction.%目的:研究aMi后nt-proBnP水平的变化对心功能不全的诊断及预测价值。方法选取96例初发aMi患者进行分析,记录24h内患者的心功能Killip分级等项目,并测定血浆nt-proBnP浓度。结果根据心功能Killip分级的各组的nt-proBnP浓度均随着级别的升高而增加,nt-proBnP和lnnt-proBnP随着心功能的减退而显著升高,差别有统计学意义(P<0.01)。结论血浆中nt-proBnP在aMi后心功能不全的高危患者中显著升高,与急性期心功能Killip分级有明显联系,可以用于aMi后心功能不全的早期诊断及预测。

  9. Output hardcopy devices

    CERN Document Server

    Durbeck, Robert

    1988-01-01

    Output Hardcopy Devices provides a technical summary of computer output hardcopy devices such as plotters, computer output printers, and CRT generated hardcopy. Important related technical areas such as papers, ribbons and inks, color techniques, controllers, and character fonts are also covered. Emphasis is on techniques primarily associated with printing, as well as the plotting capabilities of printing devices that can be effectively used for computer graphics in addition to their various printing functions. Comprised of 19 chapters, this volume begins with an introduction to vector and ras

  10. Left-sided cardiac chamber evaluation using single-phase mid-diastolic coronary computed tomography angiography: derivation of normal values and comparison with conventional end-diastolic and end-systolic phases

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Jonathan R. [Technion-Israel Institute of Technology, Haifa (Israel); Abadi, Sobhi [Rambam Health Care Campus, Medical Imaging Department, Haifa (Israel); Solomonica, Amir [Rambam Health Care Campus, Cardiology Department, Haifa (Israel); Mutlak, Diab; Aronson, Doron; Agmon, Yoram; Lessick, Jonathan [Rambam Health Care Campus, Cardiology Department, Haifa (Israel); Technion-Israel Institute of Technology, Haifa (Israel)

    2016-10-15

    With increasing use of prospective scanning techniques for cardiac computed tomography (CT), meaningful evaluation of chamber volumes is no longer possible due to lack of normal values. We aimed to define normal values for mid-diastolic (MD) chamber volumes and to determine their significance in comparison to maximum volumes. Normal ranges at MD for left ventricular (LV) volume and mass and left atrial (LA) volume were determined from 101 normal controls. Thereafter, 109 consecutive CT scans, as well as 21 post-myocardial infarction patients, were analysed to determine the relationship between MD and maximum volumes. MD volumes correlated closely with maximal volumes (r = 0.99) for both LV and LA, and could estimate maximum volumes accurately. LV mass, measured at ED or MD, were very similar (r = 0.99). Abnormal MD volumes had excellent sensitivity and specificity to detect chamber enlargement based on maximal volumes (LV 86 %, 100 %, respectively; LA 100 %, 92 %, respectively). A single MD phase can identify patients with cardiomegaly or LV hypertrophy with a high degree of accuracy and MD volumes can give an accurate estimate of maximum LV and LA volumes. circle Traditionally, helical cardiac CT provided clinically important information from chamber volume analysis. (orig.)

  11. VMS forms Output Tables

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These output tables contain parsed and format validated data from the various VMS forms that are sent from any given vessel, while at sea, from the VMS devices on...

  12. Governmentally amplified output volatility

    Science.gov (United States)

    Funashima, Yoshito

    2016-11-01

    Predominant government behavior is decomposed by frequency into several periodic components: updating cycles of infrastructure, Kuznets cycles, fiscal policy over business cycles, and election cycles. Little is known, however, about the theoretical impact of such cyclical behavior in public finance on output fluctuations. Based on a standard neoclassical growth model, this study intends to examine the frequency at which public investment cycles are relevant to output fluctuations. We find an inverted U-shaped relationship between output volatility and length of cycle in public investment. This implies that periodic behavior in public investment at a certain frequency range can cause aggravated output resonance. Moreover, we present an empirical analysis to test the theoretical implication, using the U.S. data in the period from 1968 to 2015. The empirical results suggest that such resonance phenomena change from low to high frequency.

  13. Cardiac echinococcosis

    Directory of Open Access Journals (Sweden)

    Ivanović-Krstić Branislava A.

    2002-01-01

    Full Text Available Cardiac hydatid disease is rare. We report on an uncommon hydatid cyst localized in the right ventricular wall, right atrial wall tricuspid valve left atrium and pericard. A 33-year-old woman was treated for cough, fever and chest pain. Cardiac echocardiograpic examination revealed a round tumor (5.8 x 4 cm in the right ventricular free wall and two smaller cysts behind that tumor. There were cysts in right atrial wall and tricuspidal valve as well. Serologic tests for hydatidosis were positive. Computed tomography finding was consistent with diagnosis of hydatid cyst in lungs and right hylar part. Surgical treatment was rejected due to great risk of cardiac perforation. Medical treatment with albendazole was unsuccessful and the patient died due to systemic hydatid involvement of the lungs, liver and central nervous system.

  14. Cardiac Rehabilitation

    Science.gov (United States)

    ... your risk of future heart problems, and to improve your health and quality of life. Cardiac rehabilitation programs increase ... exercise routine at home or at a local gym. You may also continue to ... health concerns. Education about nutrition, lifestyle and weight loss ...

  15. The role of adrenergic stimulation in maintaining maximum cardiac performance in rainbow trout (Oncorhynchus mykiss) during hypoxia, hyperkalemia and acidosis at 10 degrees C.

    Science.gov (United States)

    Hanson, Linda M; Obradovich, Shannon; Mouniargi, Janet; Farrell, Anthony P

    2006-07-01

    As rainbow trout approach exhaustion during prolonged exercise, they maintain maximum cardiac output despite the fact their venous blood, which bathes the heart, becomes hypoxic, acidotic and hyperkalemic. Because these factors are individually recognized to have detrimental inotropic and chronotropic effects on cardiac performance, we hypothesized that adrenergic stimulation is critical in maintaining maximum cardiac performance under these collectively adverse conditions in vivo. To test this hypothesis, maximum cardiac performance in the presence and absence of maximal adrenergic stimulation was assessed with in situ rainbow trout hearts using relevant hyperkalemic (5.0 mmol l(-1) K+), acidotic (pH 7.5) and hypoxic challenges. With tonic adrenergic stimulation (5.0 nmol l(-1) adrenaline), hearts produced only 44.8+/-14.6% of their normal maximum cardiac output when exposed under normoxic conditions (20 kPa) to the hyperkalemic, acidotic perfusate, indicating that in vivo there was no refuge from cardiac impairment even if venous blood was fully oxygenated. By contrast, maximum adrenergic stimulation (500 nmol l(-1) adrenaline), fully protected maximum cardiac performance under hyperkalemic and acidotic conditions over a wide range of oxygen availability, from normoxia to 2.0 kPa, a venous oxygen tension close to routine values in vivo. Extending the level of hypoxia to 1.3 kPa resulted in a 43.6+/-2.8% decrease in maximum cardiac output, with hearts failing when tested at 1.0 kPa. Our results suggest that adrenergic stimulation of the trout heart is critical in maintaining maximum performance during prolonged swimming tests, and probably during all forms of exhaustive activity and recovery, when venous blood is hyperkalemic, acidotic and hypoxic.

  16. Analysis of the Indicating Value of Cardiac Troponin I, Tumor Necrosis Factor-α, Interleukin-18, Mir-1 and Mir-146b for Viral Myocarditis among Children

    Directory of Open Access Journals (Sweden)

    Dahui Wang

    2016-12-01

    Full Text Available Background/Aims: The primary objective of this study is to evaluate the diagnosis effect of serum protein factors and microRNAs for children suffering from viral myocarditis (VMC. Methods: The expression levels of serum cardiac troponin I (cTnI, interleukin-18 (IL-18 and tumor necrosis factor-α (TNF-α in both VMC and control groups were examined by using the Elisa Kit. The expression levels of miR-1 and miR-146b were measured through RT-PCR. Subsequently, the Receiver Operating Characteristic (ROC curves were drawn based on the diagnostic results of VMC. Moreover, the Spearman correlation analysis was carried out to unveil the association between the indicator expression levels and the ultrasonic cardiogram results, including the left ventricular fractional shortening (FS and left ventricular ejection fraction (EF. Results: It is found that the expression levels between the VMC and control group portrait significant differences with respect to cTnI, IL-18, TNF-α, miR-1 and mIR-146b (P Conclusions: The expression levels of the TNF-α, IL-18 and cTnI and the expression levels of the miR-1 and miR-146b could be used to predict VMC among children and this approach may reinforce the diagnosis of VMC in clinical practices.

  17. 高敏心肌肌钙蛋白Ⅰ与心肌肌钙蛋白T预测心血管事件的对比研究%Compare the values of high-sensitivity cardiac troponin I versus cardiac troponin T for prediction of cardiovascular events in acute coronary syndrome

    Institute of Scientific and Technical Information of China (English)

    曹志林

    2012-01-01

    目的 比较高敏心肌肌钙蛋白(high-sensitivity cardiac troponin Ⅰ,hs-cTnI)与心肌肌钙蛋白(cardiac troponin T,cTnT)对非ST段抬高型急性冠状动脉综合征(急性冠脉综合征)患者心血管事件的预测价值.方法 采集103例连续的不稳定型心绞痛和非ST段抬高型急性心肌梗死患者的血浆样品,分别采用电化学发光免疫法和VITROS化学发光免疫分析法检测cTnT和hs-cTnI.采用工作者特征曲线评估心血管事件的发生率,确定hs-cTnI与cTnT的最佳预测值.结果 hs-cTnI与cTnT均能显著预测心血管事件,两者差异无统计学意义(P=0.75).两种心脏标志物的最佳预测值分别为hs-cTnI>0.055μg/L和cTnT>0.010μg/L,敏感度均为90%,特异度均为52%;hs-cTnI阳性患者的心血管事件发生率为17%,而hs-cTnI阴性患者的心血管事件发生率为2%,两者差异有统计学意义(P=0.02).结论 hs-cTnI与cTnT对非ST段抬高型急性冠脉综合征患者心血管事件有相似的预测诊断价值.%Objective To compare the value of high-sensitivity cardiac troponin I(hs-cTnI)versus cardiac troponin T(cTnT) for prediction of cardiovascular evenls in acute coronary syndromes. Methods The plasma samples were collected from 103 patients with unstable angina or non-ST elevation acute myocardial infarction, cTnT and hs-cTnI levels were detected by electrochemilumines-cence immunoassay and VITROS chemiluminescence immunoassay respectively. The prognostic value was compared to the occurrence of cardiovascular events during hospitalization. Results Both hs-cTnI and cTnT could significantly predict cardiovascular events and existed no significant difference(P = 0. 75). The best predictive value of the two cardiac markers were hs-cTnI> 0. 055 μg/L and cTnT> 0. 010 μg/L,the sensitivity and specificity of these two markers were 90% and 52% respectively. The incidence of cardiovascular e-vents was 17% for hs-cTnI-positive patients and 2% for hs-cTnI-negative patients( P

  18. Effects of Exercise Training on Haematology and Maximal Cardiac Output

    DEFF Research Database (Denmark)

    Bonne, Thomas Christian

    they can be a challenge in an anti-doping context. In study I nine individuals performed six weeks of endurance exercise. Intravascular volumes, Qmax and VO2max were measured before and after the training intervention. Any increases in BV were then restored by phlebotomy. After the training period, PV, RCV...... = 0.051) and time to complete 3000 m tended (P = 0.09) to increase in LHTH but not after sea level training. In study III haematological parameters were determined weekly three times before and four times after classical altitude and sea level training and ABP thresholds for [Hb], %ret, OFF...

  19. Phenylephrine Administration Increases Cardiac Output in Parasympathically Blocked Patients

    NARCIS (Netherlands)

    Kalmar, A.F.; Poterman, Marieke; Scheeren, Thomas

    2013-01-01

    Introduction:  Phenylephrine (PHE), a pure α1-agonist, is widely used to treat hypotension in anesthetized patients although controversy on its beneficial versus deleterious effects on blood flow and tissue perfusion is still vivid. Conventionally, PHE is considered to increase the arterial blood pr

  20. 动态血压负荷值对心功能影响的临床观察%Clinical research on ambulatory blood pressure loading value effect on cardiac function

    Institute of Scientific and Technical Information of China (English)

    崔永生; 何玉娟

    2001-01-01

    目的: 探讨24小时动态血压负荷值对原发性高血压患者心脏收缩及舒张功能有何影响。方法: 选择原发性高血压患者80例,应用24小时动态血压监测及超声心动图监测心功能的动力学指标:左室射血分数(LVEF),左室高峰充盈率(PFR),左室高峰射血率(PER)及二尖瓣血流舒张早期流速(EV)与左心房收缩期流速(AV)的比值(EV/AV)。根据血压负荷值<30%和>30%,将病人分为A、B、C、D四组,比较各组间心功能有无差异。结果: A组与B组比较,PFR有显著性差异,A组与C组、D组比较,LVEF和EV/AV有显著性差异性(P<0.05),PFR有非常显著性差异(P<0.01),C组与D组比较LVEF、PER、PFR、EV/AV均无显著性差异。结论: 收缩压或舒张压负荷值的升高均可显著影响高血压病患者的心室舒张功能,而后者为著。同时舒张压负荷值与心室收缩功能明显相关,可作为预测这类患者心功能改变敏感指标。%Objective: To investigate the effect of 24-hour ambulatory blood pressure loading value on cardiac contraction and relaxation function of essential hypertensive patient.Methods: Select 80 essential hypertensive patients. Use 24-hour ambulatory blood pressure monitoring and echocardiogram monitor cardiac function, and the dynamics index:left ventricular ejection fraction(LVEF), left ventricular peak filling rate(PFR), left ventricular peak ejection rate (PER), and the ratios (EV/AV) of mitral blood flow relaxation early velocity (EV) to left atrium contraction flow velocity (AV). According to the blood pressure loading value <30% and >30%,the patients are divided into 4 teams:A,B,C, and D, compare their cardiac function's deference.Results: To compare A with B,PFR is obviously different; To compare A with C,D separately, LVEF and EV/AV are greatly different(P<0.05);and PFR differ sharply (P<0.01);To compare C with D, LVEF, PER, PFR, and EV/AV has no

  1. 脉搏指示连续心排血量监测技术在骨盆骨折合并失血性休克患者中的应用及护理%Nursing of pulse-indicated continuous cardiac output technique in pelvic fracture patients with hemorrhagic shock

    Institute of Scientific and Technical Information of China (English)

    赵文静; 程人佳; 张庆红; 赵文州

    2015-01-01

    Objective To investigate the clinical nursing methods of pulse-indicated con-tinuous cardiac output(PICCO)system in pelvic fracture patients with hemorrhagic shock.Methods The clinical data of 82 pelvic fracture patients with hemorrhagic shock treated in emergency inten-sive care unit (EICU)were retrospectively analyzed.Results In 82 patients,74 improved patients transferred to other departments or discharged and 8 patients died including 6 patients with acute re-nal failure.Conclusion Pelvic fracture patients with hemorrhagic shock using PICCO technology can accurately reflect the volume state.The PICCO management and PICCO safety is the key to en-sure successful treatment.%目的:探讨脉搏指示连续心排血量监测技术(PICCO)在骨盆骨折合并失血性休克患者中的应用及护理方法。方法对急诊重症监护室(EICU)收治的82例骨盆骨折合并失血性休克患者的临床及护理资料进行回顾性分析。结果82例患者中,病情好转转科或出院74例,死亡8例,其中并发急性肾衰竭6例。结论骨盆骨折合并失血性休克患者采用 PICCO技术能精准反映患者的容量状态,在 PICCO 的管理和观察中保证 PICCO 监测安全有效是救治成功的关键。

  2. Cardiac Calcification

    Directory of Open Access Journals (Sweden)

    Morteza Joorabian

    2011-05-01

    Full Text Available There is a spectrum of different types of cardiac"ncalcifications with the importance and significance"nof each type of cardiac calcification, especially"ncoronary artery calcification. Radiologic detection of"ncalcifications within the heart is quite common. The"namount of coronary artery calcification correlates"nwith the severity of coronary artery disease (CAD."nCalcification of the aortic or mitral valve may indicate"nhemodynamically significant valvular stenosis."nMyocardial calcification is a sign of prior infarction,"nwhile pericardial calcification is strongly associated"nwith constrictive pericarditis. A spectrum of different"ntypes of cardiac calcifications (linear, annular,"ncurvilinear,... could be seen in chest radiography and"nother imaging modalities. So a carful inspection for"ndetection and reorganization of these calcifications"nshould be necessary. Numerous modalities exist for"nidentifying coronary calcification, including plain"nradiography, fluoroscopy, intravascular ultrasound,"nMRI, echocardiography, and conventional, helical and"nelectron-beam CT (EBCT. Coronary calcifications"ndetected on EBCT or helical CT can be quantifie,"nand a total calcification score (Cardiac Calcification"nScoring may be calculated. In an asymptomatic"npopulation and/or patients with concomitant risk"nfactors like diabetes mellitus, determination of the"npresence of coronary calcifications identifies the"npatients at risk for future myocardial infarction and"ncoronary artery disease. In patients without coronary"ncalcifications, future cardiovascular events could"nbe excluded. Therefore, detecting and recognizing"ncalcification related to the heart on chest radiography"nand other imaging modalities such as fluoroscopy, CT"nand echocardiography may have important clinical"nimplications.

  3. INFLUENCE OF MIMIC CARDIAC RATE ON HYDRODYNAMICS OF DIFFERENT MECHANICAL PROSTHETIC CARDIAC VALVES IN VITRO

    Institute of Scientific and Technical Information of China (English)

    Yin-ping Chu; Jin-lian Cheng; Ru-kun Chen; Yu-bo Fan; Fang Pu

    2005-01-01

    Objective To assess the influence of mimic cardiac rate on hydrodynamics of different mechanical prosthetic cardiac valves.Methods US-made CarboMedics bileaflet valve, China-made Jiuling bileaflet valve and C-L tilting disc valve were tested via a pulsatile flow simulator in the aortic position. Testing conditions were set at mimic cardiac rates of 55 bpm, 75 bpm, 100bpm with a constant mimic cardiac output of 4 L/min. The mean pressure differences (△P), leakage volumes (LEV) and closing volumes (CLV) across each valve, and effective orifice areas (EOA) were analyzed.Results Within physiological range, △p, LEV, and CLV decreased as mimic cardiac rate increased, with a large extent of variance. EOA increased along with an increase in mimic cardiac rate. It was a different response in terms of cardiac rate alteration for different types of mechanical prosthetic cardiac valves.Conclusion Mimic cardiac rate change affects hydrodynamics of mechanical prosthetic cardiac valves. Within physiological range, the hydrodynamic of prosthetic bileaflet valve is better than that of tilting disc valve.

  4. APPROXIMATE OUTPUT REGULATION FOR AFFINE NONLINEAR SYSTEMS

    Institute of Scientific and Technical Information of China (English)

    Yali DONG; Daizhan CHENG; Huashu QIN

    2003-01-01

    Output regulation for affine nonlinear systems driven by an exogenous signal is investigated in this paper. In the absence of the standard exosystem hypothesis, we assume availability of the instantaneous values of the exogenous signal and its first time-derivative for use in the control law.For affine nonlinear systems, the necessary and sufficient conditions of the solvability of approximate output regulation problem are obtained. The precise form of the control law is presented under some suitable assumptions.

  5. 肌钙蛋白对心脏外科手术后急性心肌梗死的诊断价值%Discussing the diagnostic value of troponin in the acute myocardial infarction after cardiac surgery

    Institute of Scientific and Technical Information of China (English)

    梁林宝; 程国栋; 朱春磊; 陈国锋; 陈乃颖; 黄伟

    2014-01-01

    Objective To research the diagnostic value of troponin in the acute myocardial infarction after cardiac surgery.Methods The prospective study method was used.One hundred and thirtyfour patients of cardiac surgery were selected as observation group,36 patients of thoracic surgery were selected as control group.All the patients were given continuous electrocardiogram monitoring and measured troponin I,and the results were compared between the 2 groups.Results There was no statistical difference in the troponin I before anesthesia between the 2 groups (P > 0.05).The troponin I 4 h after surgery was (13.010 ± 14.829) μg/L in observation group,(0.019 ± 0.007) μg/L in control group,there was statistical difference (P < 0.05).One case of observation group happened the acute myocardial infarction after cardiac surgery,the troponin I was > 40.000 μ g/L.Conclusions The troponin is obviously increased in the early stage in most patients of cardiac surgery,the false positive rate in diagnostic acute myocardial infarction is higher according to the troponin.For troponin,it will need the more evidence of evidence-based medicine to establish the diagnosis of acute myocardial infarction after cardiac surgery.%目的 探讨肌钙蛋白对心脏外科手术后急性心肌梗死的诊断价值.方法 采用前瞻性研究方法,选择134例心脏手术患者作为观察组,同期36例胸科手术患者作为对照组,两组患者术后持续心电监护,检测肌钙蛋白I,并对结果进行比较.结果 两组麻醉前肌钙蛋白I比较差异无统计学意义(P>0.05).观察组术后4h肌钙蛋白I为(13.010±14.829) μg,/L,与对照组的(0.019±0.007) μg/L比较差异有统计学意义(P<0.05).观察组发生急性心肌梗死1例,其肌钙蛋白Ⅰ>40.000 μg/L.结论 心脏外科手术后早期绝大部分患者的肌钙蛋白明显增高,根据肌钙蛋白诊断术后急性心肌梗死的假阳性率较高,有待更多循证医学证据制定肌钙蛋白对

  6. A Monte Carlo Study on Multiple Output Stochastic Frontiers

    DEFF Research Database (Denmark)

    Henningsen, Géraldine; Henningsen, Arne; Jensen, Uwe

    In the estimation of multiple output technologies in a primal approach, the main question is how to handle the multiple outputs. Often an output distance function is used, where the classical approach is to exploit its homogeneity property by selecting one output quantity as the dependent variable...... of both specifications for the case of a Translog output distance function with respect to different common statistical problems as well as problems arising as a consequence of zero values in the output quantities. Although, our results partly show clear reactions to statistical misspecifications...

  7. Cardiac autonomic nervous test value to the diagnosis of plant diabetic neuropathy%心脏自主神经试验对糖尿病合并植物神经病变的诊断价值

    Institute of Scientific and Technical Information of China (English)

    何煜暐

    2015-01-01

    目的:对46例糖尿病患者心脏自主神经试验进行分析,探讨心脏自主神经试验对糖尿病合并植物神经病变的诊断价值。方法:根据临床表现把糖尿病患者分为糖尿病合并植物神经病变组和糖尿病不合并植物神经病变组。行心脏自主神经试验,并对两组数据进行比较。结果:糖尿病合并植物神经病变组呼吸差,乏氏指数、30/15比值均低于不合并植物神经病变组。结论:心脏自主神经试验方法简单方便,容易掌握,重复性好,可作为评估糖尿病合并植物神经病变的敏感指标。%Objective46 cases of diabetic cardiac autonomic nervous test were analyzed, and discuss the heart autonomic nervous test value to the diagnosis of plant diabetic neuropathy.MethodsThe diabetes patients according to clinical manifestations of divided into diabetic neuropathy group and diabetes do not merge plants group of neuropathy. Heart the heart nerve test, and carries on the comparison to 2 sets of data.ResultsPlant diabetic neuropathy group of poor breathing, lack of index, the ratio of 30/15 were less merger plant neuropathy group.Conclusions Cardiac autonomic nervous test method is simple and convenient, easy to learn, good repeatability, can be used as evaluation of sensitive indicator of plant diabetic neuropathy.

  8. 心血管整体评分评估胎儿心功能不全的价值%The Value of Cardiovascular Profile Score to Assess Fetal Cardiac Insufficiency

    Institute of Scientific and Technical Information of China (English)

    武超; 王玲红; 刘丽萍

    2016-01-01

    Jan. 2016. Fetal cardiac insufficiency (enlarged heart and myocardial contraction fatigue) were found out. CVPS were recorded. Meanwhile fetal cadiography were performed to define if congenital heart disease were accompanied. All cases divided in two groups based on the follow up results:live birth group and adverse pregnancy outcome group. Results:38 cases of fetal cardiac insufficiency were found out. 35 cases were singleton pregnancy. 3 cases were twins pregnancy. 12 cases were in live birth group (all of them were singleton pregnancy), 10 cases were healthy children, 2 cases were accompanied by congenital heart disease: 1 case was mild pulmonicstenosis, 1 case was tetralogy of Fallot. 21 cases were in adverse pregnancy outcome group. 18 cases were singleton pregnancies: 9 cases were intrauterine fetal demise, 2 cases were stillbirth, 7 cases were induced labour: 5 cases progressed to heart failure because of CVPS declined continuously and fetal cadiac insufficiency worsen, 2 cases were accompanied by fatal congenital heart disease. 2 cases of twins pregnancy were intrauterine fetal demise because of twin to twin transfusion syndrome (TTTS). 1 case of twins pregnancy was induced labour because of hydrocephaly and intracranial hemorrhage. 5 cases were loss to follow up. CVPS of live birth was 7.62 (7.00) and CVPS of adverse pregnancy outcomes was 5.67 (3.50). Statistics analysis:ROC curve analysis, area under ROC:0.823, cut off value was 6.5, P=0.002, difference was statistically significant. The score of umbilical artery doppler spectrum, vein doppler spectrum and cardiac valve function in two groups were significant difference (P<0.05). Conclusions:CVPS declined when fetal cardiac insufficiency worse, dangerous cut off value of CVPS was 6.5, CVPS is an effective index for continuous dynamic assessment of fetal cardiac insufficiency. The score of umbilical artery doppler spectrum, vein doppler spectrum and cardiac valve function were valuable to predict adverse

  9. 脓毒性休克患者血浆脑钠肽与 PiCCO 相关指标的关系%The correlation between plasma brain natriuretic peptide (BNP)levels and parameters of pulse -indicated continuous cardiac output(PiCCO)in patients with septic shock

    Institute of Scientific and Technical Information of China (English)

    吴翔; 陶飞; 胡桂芳; 邓烈华; 姚华国

    2016-01-01

    Objective To investigate the relationship between plasma brain natriuretic peptide (BNP)levels and the monito-ring indicators of pulse -indicated continuous cardiac output (PiCCO)in patients with sepstic shock.Methods 48 patients with septic shock according to the criteria of sepsis set by SC-CN /ESICM/ACCP /ATS /SIS were selected.Clinical and laboratory data including BNP were collected on the 1 d,3rd and 5 th day after admittion.The hemodynamics of the patients was monitored using PiCCO technology,and the heart function indexs were recorded,incluing CI,CFI,GEF and dP /dPmax.Acute Physiology and Chronic Health Evaluation (APACHEⅡ)and Sepsis -related Organ Failure Assessment (SOFA)score were determined.The correlation between BNP levels and the above indexs was analyzed.Results The levels of plasma BNP had negative correlation with CI,CFI,GEF (r =-0.339, -0.250, -0.241 ,P 0.05 ).The levels of plasma BNP had significant positive correlation with APACHEII scores and SOFA scores (r =0.509,0.565 ,P <0.05 ). Conclusion The cardiac function could not be reflected by BNP levels in septic shock patients.Plasma BNP levels can re-flect the severity of septic shock in certain degree,and might be considered as a valuable prognostic factor for patients with septic shock.%目的:通过监测脓毒性休克患者血浆脑钠肽(BNP)水平以及脉搏指示连续心排血量(PiCCO)相关指标的变化,探讨脓毒性休克患者脑钠肽水平与心功能的关系。方法选取48例脓毒性休克患者为研究对象,检测患者入 ICU第1、3、5天血浆 BNP 水平,通过 PiCCO 技术对患者进行血流动力学监测,记录反应心功能指标的 CI、CFI、GEF 和 dP/dP-max,并进行 APACHEⅡ、SOFA 评分,分析 BNP 与上述指标的相关性。结果脓毒性休克患者血浆 BNP 水平与 CI 、CFI、GE 呈负相关(r =-0.339、-0.25、-0.241,P <0.05),与 dP/dPmax 无显著相关性(P >0.05

  10. Normal cardiac function in mice with supraphysiological cardiac creatine levels.

    Science.gov (United States)

    Santacruz, Lucia; Hernandez, Alejandro; Nienaber, Jeffrey; Mishra, Rajashree; Pinilla, Miguel; Burchette, James; Mao, Lan; Rockman, Howard A; Jacobs, Danny O

    2014-02-01

    Creatine and phosphocreatine levels are decreased in heart failure, and reductions in myocellular phosphocreatine levels predict the severity of the disease and portend adverse outcomes. Previous studies of transgenic mouse models with increased creatine content higher than two times baseline showed the development of heart failure and shortened lifespan. Given phosphocreatine's role in buffering ATP content, we tested the hypothesis whether elevated cardiac creatine content would alter cardiac function under normal physiological conditions. Here, we report the creation of transgenic mice that overexpress the human creatine transporter (CrT) in cardiac muscle under the control of the α-myosin heavy chain promoter. Cardiac transgene expression was quantified by qRT-PCR, and human CrT protein expression was documented on Western blots and immunohistochemistry using a specific anti-CrT antibody. High-energy phosphate metabolites and cardiac function were measured in transgenic animals and compared with age-matched, wild-type controls. Adult transgenic animals showed increases of 5.7- and 4.7-fold in the content of creatine and free ADP, respectively. Phosphocreatine and ATP levels were two times as high in young transgenic animals but declined to control levels by the time the animals reached 8 wk of age. Transgenic mice appeared to be healthy and had normal life spans. Cardiac morphometry, conscious echocardiography, and pressure-volume loop studies demonstrated mild hypertrophy but normal function. Based on our characterization of the human CrT protein expression, creatine and phosphocreatine content, and cardiac morphometry and function, these transgenic mice provide an in vivo model for examining the therapeutic value of elevated creatine content for cardiac pathologies.

  11. 体外膜氧合成功救治新生儿心脏术后严重低心排综合征一例%Extracorporeal membrane oxygenation treatment of a neonate with severe low cardiac output syndrome following open heart surgery

    Institute of Scientific and Technical Information of China (English)

    林茹; 谈林华; 张泽伟; 孙眉月; 杜立中

    2008-01-01

    目的 总结ECMO救治新生儿心脏术后严重低心排的成功经验.方法 2007年7月18日我们对一例患先天性大动脉转位(TGA)合并房间隔缺损(ASD)、动脉导管未闭(PDA)2.8 kg出生6 d的新生儿,进行了大动脉调转术(arteries switch)、ASD修补、PDA结扎术,畸形矫正后出现严重低心排综合征,低血压[<39/30 mm Hg(1 mm Hg=0.133 kPa)]、高乳酸血症(Lac 8.8 mmol/L)、高左房压(LAP>20 mm Hg)、血性痰、少尿[<1 ml/(kg·h)],由于转流时间较长(263 min)且难以脱离体外循环,常规治疗无效后接V-A ECMO进行心肺辅助.结果 经87h ECMO辅助后,左心功能明显恢复,患儿顺利脱离ECMO,ECMO第1天LVEF 20%,第2天34%,第3天43%;ECMO第1天CKMB 41 μ/L,第2天恢复正常.脱离ECMO后,在较高浓度血管活性药支持下[肾上腺素0.2 μg/(kg·min),多巴胺/多巴酚丁胺8 μg/(kg·min),米力农0.56 μg/(kg·min)],循环基本稳定.ECMO撤离后第4天,关闭胸部切口.ECMO撤离后第22天,撤离呼吸机,术后30 d撤离血管活性药.术后58 d康复出院.出院时心肺、肝肾功能正常,神志清醒,四肢肌张力和运动正常.整个病程中多次头颅超声检查均未发现脑出血、梗死等病灶.ECMO并发症:(1)肺出血;(2)伤口出血和心包填塞;(3)溶血;(4)高胆红素血症.结论 ECMO对抢救新生儿心脏术后严重心功能不全有良好的疗效.%Objective To summarize the experience of extracorporeal membrane oxygenation (ECMO)to rescue a neonate with severe low cardiac output syndrome following open heart surgery.Methods The patient was a male,2 d,2.8 kg,G3P2 full-term neonate with gestational age 40 weeks,born by Cesarean-section with Apgar score of 10 at 1 min.He was admitted due to severe dyspnea with oxygen desaturation and heart murmur on the second day after birth.Physical examination showed clear consciousness,cyanosis,dyspnea,RR 70 bpm and a grade Ⅱ/6 heart murmur.Bp was 56/45 mm Hg (1 mm Hg=0.133 kPa)and SpO2 around 65

  12. The value of FDG-PET/CT in the diagnostic work-up of extra cardiac infectious manifestations in infectious endocarditis

    DEFF Research Database (Denmark)

    Ozcan, C; Asmar, A; Gill, S;

    2013-01-01

    Infectious endocarditis (IE) is a serious condition with a high morbidity and mortality. The optimal management of IE depends not only on correct antibiotic therapy and surgery when needed, but involves identification of the portal of entry and detection of extracardiac infectious manifestations....... To discover the latter an (18)F-fluorodeoxyglucose positron emission tomography ((18)F-FDG-PET)/CT examination has been proposed. However, the diagnostic value of a PET/CT in this setting remains unresolved. Thus, we wished to assess the usefulness of a PET/CT study in patients with IE as a supplemental...... method to standard work-up in evaluating primary and distant infective foci. A retrospective cohort study of 72 IE patients admitted from 2008 to 2010, which had an (18)F-FDG-PET/CT performed. Findings were assessed in relation to the routine work-up, which served as the "gold standard". One hundred...

  13. New drugs targeting the cardiac ultra-rapid delayed-rectifier current (I Kur): rationale, pharmacology and evidence for potential therapeutic value.

    Science.gov (United States)

    Ford, John W; Milnes, James T

    2008-08-01

    There is a clear unmet medical need for new pharmacologic therapies for the treatment of atrial fibrillation (AF) with improved efficacy and safety. This article reviews the development of new and novel Kv1.5/ultra-rapid delayed-rectifier current (I Kur) inhibitors and presents evidence that Kv1.5 modulation provides an atrial-selective mechanism for treating AF. Academia and industry have invested heavily in Kv1.5 (>500 scientific publications and >50 patents published since 1993); however, to realize the full value of this therapeutic drug target, clinical efficacy and safety data are required for a selective Kv1.5 modulator. The reward for demonstrating clinical efficacy and safety in a pivotal Phase 3 trial, on regulatory approval, is "first in class" status.

  14. Multimodality imaging for resuscitated sudden cardiac death.

    Science.gov (United States)

    Chen, Yingming Amy; Deva, Djeven; Kirpalani, Anish; Prabhudesai, Vikram; Marcuzzi, Danny W; Graham, John J; Verma, Subodh; Jimenez-Juan, Laura; Yan, Andrew T

    2015-01-01

    We present a case that elegantly illustrates the utility of two novel noninvasive imaging techniques, computed tomography (CT) coronary angiography and cardiac MRI, in the diagnosis and management of a 27-year-old man with exertion-induced cardiac arrest caused by an anomalous right coronary artery. CT coronary angiography with 3D reformatting delineated the interarterial course of an anomalous right coronary artery compressed between the aorta and pulmonary artery, whereas cardiac MRI showed a small myocardial infarction in the right coronary artery territory not detected on echocardiography. This case highlights the value of novel multimodality imaging techniques in the risk stratification and management of patients with resuscitated cardiac arrest.

  15. Cardiac hybrid imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gaemperli, Oliver [University Hospital Zurich, Cardiac Imaging, Zurich (Switzerland); University Hospital Zurich, Nuclear Cardiology, Cardiovascular Center, Zurich (Switzerland); Kaufmann, Philipp A. [University Hospital Zurich, Cardiac Imaging, Zurich (Switzerland); Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland)

    2014-05-15

    Hybrid cardiac single photon emission computed tomography (SPECT)/CT imaging allows combined assessment of anatomical and functional aspects of cardiac disease. In coronary artery disease (CAD), hybrid SPECT/CT imaging allows detection of coronary artery stenosis and myocardial perfusion abnormalities. The clinical value of hybrid imaging has been documented in several subsets of patients. In selected groups of patients, hybrid imaging improves the diagnostic accuracy to detect CAD compared to the single imaging techniques. Additionally, this approach facilitates functional interrogation of coronary stenoses and guidance with regard to revascularization procedures. Moreover, the anatomical information obtained from CT coronary angiography or coronary artery calcium scores (CACS) adds prognostic information over perfusion data from SPECT. The use of cardiac hybrid imaging has been favoured by the dissemination of dedicated hybrid systems and the release of dedicated image fusion software, which allow simple patient throughput for hybrid SPECT/CT studies. Further technological improvements such as more efficient detector technology to allow for low-radiation protocols, ultra-fast image acquisition and improved low-noise image reconstruction algorithms will be instrumental to further promote hybrid SPECT/CT in research and clinical practice. (orig.)

  16. SODIUM BICARBONATE INFUSION: TO PREVENT CARDIAC SURGERY - ASSOCIATED ACUTE KIDNEY INJURY

    Directory of Open Access Journals (Sweden)

    Ramesh

    2015-02-01

    Full Text Available OBJECTIVES: The incidence of cardiac surgery – associated acute kidney injury is 50% of patients and is associated with increased mortality and morbidity. This study aimed to determine if perioperative urinary and plasma alkalization with sodium bicarbonate infusion re duces the incidence of cardiac surgery – associated acute kidney injury. SETTING AND DESIGN: This study is double blind randomized control trial conducted at U N Mehta Institute of Cardiology and Research Center , India. METHOD S AND RESULT: A total of 140 pat ients scheduled to undergo elective cardiac surgery , who were at increased risk of development of cardiac surgery – associated acute kidney injury using recognized risk factors. Patients were randomly allocated to receive either sodium bicarbonate (n = 70 o r sodium chloride (n = 70 infusion , commencing at the start of anesthesia , in a dose of 4 mmol/kg over 24 hour. The primary outcome measure was the number of patients with development of CSA - AKI , defined as an increase in creatinine greater than 25% from baseline to peak value within the first three postoperative days. Significant differences among the groups in both plasma and urinary pH were achieved 6 hours after commencement of the infusion , and these changes persisted for more than 24 hours. A total o f 7 out of 70(10% patients in the sodium bicarbonate group and 16 out of 70(22.85% patients in the sodium chloride group developed acute kidney injury within the first three postoperative days with p value of 0.06 which is statistically not significant . There were also no significant differences in ventilation hours , ICU or hospital length of stay , or mortality. CONCLUSIONS: Perioperative alkalization of blood and urine using an infusion of sodium bicarbonate did not result in a decrease in the incidence of acute kidney injury in patients undergoing cardiac surgery. KEYWORDS: Acute kidney injury; Cardiac surgery; Cardiopulmonary bypass; Creatinine

  17. Improvement of cardiac function after kidney transplantation with dilated cardiomyopathy and long dialysis vintage.

    Science.gov (United States)

    Mimura, Imari; Kawarazaki, Hiroo; Momose, Toshimitsu; Shibagaki, Yugo; Fujita, Toshiro

    2009-12-01

    Patients with long dialysis vintage have low cardiac output for various reasons. Although kidney transplantation is known to improve cardiac mortality, patients are sometimes evaluated as contraindicated for transplantation because of cardiac risk. We successfully performed kidney transplantation for a patient with a long dialysis vintage and dilated cardiomyopathy. Sequential (123)I-metaiodobenzylguanidine ((123)I-MIBG) scintigraphy suggested that amelioration of uraemia improved cardiac function. Kidney transplantation for patients with severely impaired cardiac function is safe and effective under careful perioperative monitoring irrespective of dialysis vintage. Sequential (123)I-MIBG scintigraphy can be used as an evaluation tool for the improvement in cardiac function.

  18. A new nonlinear output tracking controller via output-feedback

    Institute of Scientific and Technical Information of China (English)

    Yun ZHANG; Yungang LIU; Yuqin DING

    2006-01-01

    In this paper, the output tracking control is investigated for a class of nonlinear systems when only output is available for feedback. Based on the multivariable analog of circle criterion, an observer is first introduced. Then, the observer-based output tracking controller is constructively designed by using the integral backstepping approach together with completing square. It is shown that, under relatively mild conditions, all the closed-loop signals are uniformly bounded.Meanwhile the system output asymptotically tracks the desired output. A simulation example is given to illustrate the effectiveness of the theoretical results.

  19. Cardiac MRI in Athletes

    NARCIS (Netherlands)

    Luijkx, T.

    2012-01-01

    Cardiac magnetic resonance imaging (CMR) is often used in athletes to image cardiac anatomy and function and is increasingly requested in the context of screening for pathology that can cause sudden cardiac death (SCD). In this thesis, patterns of cardiac adaptation to sports are investigated with C

  20. Contribution of tourism to tertiary industry’s output value--taking Hubei Province as an example%旅游产业对第三产业产值的贡献度分析--以湖北省为例

    Institute of Scientific and Technical Information of China (English)

    周薇薇; 胡晓峰; 曹俊华

    2013-01-01

    In view of the contribution of tourism industry to the tertiary industry , analyses were made of the relationship between total tourism income, the output value of tertiary in-dustry and foreign exchange earnings from tourism based on VAR Model and the data of total tourism income, total foreign exchange earnings from tourism and output value of ter-tiary industry of Hubei Province from 1986 to 2011 . The results show that 1 percent in-crease in the provincial tourism output will lead to 0.18 percent increase in the average output value of tertiary industry. With 1 percentage increase in the total foreign exchange earnings from tourism, the average output value of tertiary industry will increase by 0.25 percent. The study shows that domestic tourism market plays greater effect on the tertiary industry than the international one.%  针对旅游产业的贡献问题,利用湖北省1986—2010年湖北省旅游总收入、第三产业产值以及旅游外汇收入相关数据建立VAR模型分析了湖北省旅游总收入、旅游外汇收入以及第三产业产值的互动关系.研究结果表明:湖北省省内旅游产值每增长1个百分点,则第三产业产值平均会增加0.18个百分点.湖北省国际旅游外汇收入每增加1个百分点,第三产业产值平均将会增加0.25个百分点.国内旅游市场对第三产业产值的影响要比国际旅游市场对第三产业的影响要大.

  1. Response requirements as constraints on output.

    Science.gov (United States)

    Zeiler, M D; Buchman, I B

    1979-07-01

    Two experiments studied how added response requirements affected fixed-interval schedule performance. Experiment 1 involved tandem fixed-interval fixed-ratio schedules, and Experiment 2 studied conjunctive fixed-interval fixed-ratio schedules. In both, pigeons' output, defined as overall response rate or as responses during the interval, first increased and then decreased as the ratio was raised. With small ratio requirements, the frequency of reinforcement in time either did not change or decreased slightly. With progressively larger ratios, reinforcement frequency decreased consistently. Alternative explanations were discussed. The first, a reinforcement theory account, was that response strength is an increasing monotonic function of both the response requirement and reinforcement frequency, and the bitonic output function represents interacting effects. Increases in the response requirement accompanied by small changes in reinforcement frequency enhance output, but further increases result in large enough decrements in reinforcement frequency so that output is lowered. The second explanation does not view reinforcement as a basic process but, instead, derives from concepts of economics and conservation. Organisms allocate their behavior among alternatives so as to maximize value, where value is a function of the responses that can occur in a given situation under the set of restrictions imposed by particular schedules. One form of this theory explicitly predicts that output is a bitonic function of ratio requirements in simple ratio schedules. However, it was not clear that this model could explain the present effects involving joint ratio and interval schedule restrictions.

  2. 产前应用彩色多普勒超声诊断胎儿心脏畸形的临床价值%Clinical value of color Doppler ultrasound in diagnosis of fetal cardiac malformations

    Institute of Scientific and Technical Information of China (English)

    丁宏军

    2015-01-01

    Objective To study the clinical value of color Doppler ultrasound in the diagnosis of fetal cardiac malformations. Methods From our hospital 176 cases (69 cases of maternal heart disease) in pregnant women as the research object, the fetuses of color doppler ultrasound,Analysis of ultrasound images and compare postnatal pathological results.Results Two checking methods of coincidence rate was 84.62%, the difference was not statistically significance (P > 0.05). And the mother has a history of heart disease, fetal heart disease 13.04%; The mother has no history of heart disease, fetal heart disease 1.87%.Conclusion Pregnant women have a history of heart disease especially pay attention to the growth of fetus during pregnancy, and color doppler ultrasonography can diagnose cardiac malformation fetus,and the diagnosis rate is high, no obvious adverse reactions, so the method is worthy of clinical application and promotion.%目的::研究产前应用彩色多普勒超声诊断胎儿心脏畸形的临床价值。方法:选取我院176例(其中69例母体有心脏病史)中孕期的妇女作为研究对象,对腹中的胎儿进行彩色多普勒超声检查,检查胎儿心脏情况,分析超声图像并对比产后胎儿的病理检查结果。结果:两种检查方法的符合率为84.62%,差异没有统计学意义(P>0.05)。且母体有心脏病史,胎儿有心脏病的比例为13.04%;母体没有心脏病史,胎儿有心脏病的比例为1.87%。结论:孕妇有心脏病史时在怀孕期间尤其注意胎儿的发育情况,另外彩色多普勒超声可以诊断胎儿心脏畸形,且诊断率高,无明显不良反应,因此该方法是值得临床上应用以及推广的。

  3. Output filters for AC adjustable speed drives

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Hanigovszki, Norbert; Landkildehus, Jorn, Jorn

    2007-01-01

    -phase applications the occurrence of common-mode (CM) voltage is inherent due to asymmetrical output pulses [1]. Consequently, several secondary effects arise at the inverter's output: high-frequency conducted and radiated emissions, leakage current, motor insulation stress due to wave reflection [2], bearing stress......The standard industrial solution for adjustable speed drives (ASD) is the use of induction motors (IM) fed by voltage-source inverters (VSI). The inverter generates a pulsewidth modulated (PWM) voltage, with dv/dt values of about 6 kV/¿s or even more. In three-leg inverters for three...

  4. Avaliação dos valores séricos de troponina I cardíaca em crianças menores de 1 ano de idade Evaluation of serum cardiac troponin I values in children less than 1 year of age

    Directory of Open Access Journals (Sweden)

    Antonio Carlos Arruda Souto

    2008-09-01

    Full Text Available OBJETIVO: Verificar os valores séricos para troponina I cardíaca em crianças abaixo de um ano de idade, sem disfunção cardíaca clínica. MÉTODOS: Os níveis séricos de troponina I cardíaca foram determinados em 99 crianças com idade abaixo de um ano, incluindo-se recém-nascidos a termo, sem doenças relacionadas a comprometimento da função cardíaca identificável clinicamente, por meio do kit específico Opus T Troponin I (cTn (Dade Behring Inc. - Newalk, DE 19714, USA. RESULTADOS: A dosagem sérica de troponina I cardíaca apresentou, em todos os pacientes, valor menor que 0,1 ng/ml. CONCLUSÃO: Verificamos que o valor da dosagem sérica de troponina I cardíaca é menor do que 0,1 ng/ml para pacientes pediátricos, sem disfunção cardíaca, desde recém-nascidos a termo até um ano de idade, quando realizada por meio do kit Opus T Troponin I (cTn test modules.OBJECTIVE: The objective is to verify the cardiac troponin I values in children less than 1 year of age without clinical cardiac dysfunction. METHODS: The cardiac troponin I values were determined in 99 children less than 1 year of age, including term infants without diseases related to cardiac dysfunction using the specific kit Opus T Troponin I (cTn (Dade Behring Inc. -Newalk, DE 19714, USA. RESULTS: All children have values of cardiac troponin I less than 0.1 ng/ml. CONCLUSION: We verified that the cardiac troponin I value is less than 0.1 ng/ml in children less than 1 year, including term infants without cardiac dysfunction, when analized by the kit Opus T Troponin I (cTn test modules.

  5. Débito cardíaco e fração de ejeção fetal por meio do spatio-temporal image correlation (STIC: comparação entre fetos masculinos e femininos Fetal cardiac output and ejection fraction by spatio-temporal image correlation (STIC: comparison between male and female fetuses

    Directory of Open Access Journals (Sweden)

    Christiane Simioni

    2012-06-01

    Full Text Available OBJETIVO: Comparar do débito cardíaco (DC e a fração de ejeção (FE do coração de fetos masculinos e femininos obtidos por meio da ultrassonografia tridimensional, utilizando o spatio-temporal image correlation (STIC. MÉTODOS: Realizou-se um estudo de corte transversal com 216 fetos normais, entre 20 a 34 semanas de gestação, sendo 108 masculinos e 108 femininos. Os volumes ventriculares no final da sístole e diástole foram obtidos por meio do STIC, sendo as avaliações volumétricas realizadas pelo virtual organ computer-aided analysis (VOCAL com rotação de 30º. Para o cálculo do DC utilizou-se a fórmula: DC= volume sistólico/frequência cardíaca fetal, enquanto que para a FE utilizou-se a fórmula: FE= volume sistólico/volume diastólico final. O DC (combinado, feminino e masculino e a FE (masculina e feminina foram comparadas utilizando-se o teste t não pareado e ANCOVA. Foram criados gráficos de dispersão com os percentis 5, 50 e 95. RESULTADOS: A média do DC combinado, DC direito, DC esquerdo, FE direita e FE esquerda, para feminino e masculino, foram 240,07 mL/min; 122,67 mL/min; 123,40 mL/min; 72,84%; 67,22%; 270,56 mL/min; 139,22 mL/min; 131,34 mL/min; 70,73% e 64,76%, respectivamente; sem diferença estatística (P> 0,05. CONCLUSÕES: O DC e a FE fetal obtidos por meio da ultrassonografia tridimensional (STIC não apresentaram diferença significativa em relação ao gênero.OBJECTIVE: To compare the cardiac output (CO and ejection fraction (EF of the heart of male and female fetuses obtained by 3D-ultrasonography using spatio-temporal image correlation (STIC. METHODS: We conducted a cross-sectional study with 216 normal fetuses, between 20 and 34 weeks of gestation, 108 male and 108 female. Ventricular volumes at the end of systole and diastole were obtained by STIC, and the volumetric assessments performed by the virtual organ computer-aided analysis (VOCAL rotated 30º. To calculate the DC used the formula

  6. Application of pulse indicator continuous cardiac output monitor in the fluid resuscitation therapy in elderly patients with septic shock%脉搏指示连续心排血量监护仪在老年感染性休克液体复苏治疗中的应用

    Institute of Scientific and Technical Information of China (English)

    林华; 郑瑞强; 吴晓燕; 於江泉; 卢年芳; 邵俊; 王海霞

    2012-01-01

    Objective To investigate the guiding significance of pulse indicator continuous cardiac output(PICCO) for the fluid resuscitation in elderly patients with septic shock. Methods Twenty-four elderly patients with septic shock were divided into observation group and control group,twelve cases in each group. The patients in observation group were treated with fluid resuscitation under the guidance of PICCO monitor, while the patients in control group were treated with fluid resuscitation under the guidance of monitoring central venous pressure, then the curative effect was compared between the two groups. Results On the first day of treatment, there was no statistical difference in the blood cell and neutrophil counts, mixed venous oxygen saturation ( SvO2) ,the levels of procalcitonin ( PCT) and lactic acid (LA) between the two groups (P >0. 05). On the second and third days of treatment, the white blood cell, neutrophil counts and the levels of LA and PCT in observation group were significantly lower than those in control group(P <0. 05) ,but SvO2 was significantly higher( P < 0. 05). Compared with control group,the mechanical ventilation time was significantly shorter(P <0. 05) , and the case fatality within 28 days was lower in observation group( P < 0.05 ). Conclusion PICCO monitor has important guiding significance in the treatment of fluid resuscitation in elderly patients with septic shock,which can significantly improve blood gas analysis index,shorten the mechanical ventilation time and reduce mortality.%目的 探讨脉搏指示连续心排血量(PICCO)监测技术对老年感染性休克液体复苏治疗的指导意义.方法 24例老年感染性休克患者分为观察组和对照组,每组12例.观察组患者在PICCO监护仪监测指导下补液治疗,对照组患者在监测中心静脉压指导下补液治疗;观察比较2组治疗效果.结果 治疗第1天,2组患者白细胞、中性粒细胞计数、混合静脉血氧饱和度(SvO2)、血降

  7. Dynamic NMR cardiac imaging in a piglet

    Energy Technology Data Exchange (ETDEWEB)

    Doyle, M.; Rzedzian, R.; Mansfield, P. (Nottingham Univ. (UK). Dept. of Physics); Coupland, R.E. (Nottingham Univ. (UK). Queen' s Medical Centre)

    1983-12-01

    NMR echo-planar imaging (EPI) has been used in a real-time mode to visualise the thorax of a live piglet. Moving pictures are available on an immediate image display system which demonstrates dynamic cardiac function. Frame rates vary from one per cardiac cycle in a prospective stroboscopic mode with immediate visual output to a maximum of 10 frames per second yielding up to six looks in one piglet heart cycle, but using a visual playback mode. A completely new system has been used to obtain these images, features of which include a probe assembly with 22 cm access and an AP400 array processor for real-time data processing.

  8. Serial Input Output

    Energy Technology Data Exchange (ETDEWEB)

    Waite, Anthony; /SLAC

    2011-09-07

    Serial Input/Output (SIO) is designed to be a long term storage format of a sophistication somewhere between simple ASCII files and the techniques provided by inter alia Objectivity and Root. The former tend to be low density, information lossy (floating point numbers lose precision) and inflexible. The latter require abstract descriptions of the data with all that that implies in terms of extra complexity. The basic building blocks of SIO are streams, records and blocks. Streams provide the connections between the program and files. The user can define an arbitrary list of streams as required. A given stream must be opened for either reading or writing. SIO does not support read/write streams. If a stream is closed during the execution of a program, it can be reopened in either read or write mode to the same or a different file. Records represent a coherent grouping of data. Records consist of a collection of blocks (see next paragraph). The user can define a variety of records (headers, events, error logs, etc.) and request that any of them be written to any stream. When SIO reads a file, it first decodes the record name and if that record has been defined and unpacking has been requested for it, SIO proceeds to unpack the blocks. Blocks are user provided objects which do the real work of reading/writing the data. The user is responsible for writing the code for these blocks and for identifying these blocks to SIO at run time. To write a collection of blocks, the user must first connect them to a record. The record can then be written to a stream as described above. Note that the same block can be connected to many different records. When SIO reads a record, it scans through the blocks written and calls the corresponding block object (if it has been defined) to decode it. Undefined blocks are skipped. Each of these categories (streams, records and blocks) have some characteristics in common. Every stream, record and block has a name with the condition that each

  9. Inverter communications using output signal

    Energy Technology Data Exchange (ETDEWEB)

    Chapman, Patrick L.

    2017-02-07

    Technologies for communicating information from an inverter configured for the conversion of direct current (DC) power generated from an alternative source to alternating current (AC) power are disclosed. The technologies include determining information to be transmitted from the inverter over a power line cable connected to the inverter and controlling the operation of an output converter of the inverter as a function of the information to be transmitted to cause the output converter to generate an output waveform having the information modulated thereon.

  10. Nonlinear input-output systems

    Science.gov (United States)

    Hunt, L. R.; Luksic, Mladen; Su, Renjeng

    1987-01-01

    Necessary and sufficient conditions that the nonlinear system dot-x = f(x) + ug(x) and y = h(x) be locally feedback equivalent to the controllable linear system dot-xi = A xi + bv and y = C xi having linear output are found. Only the single input and single output case is considered, however, the results generalize to multi-input and multi-output systems.

  11. Output Model of Steel Plant

    Institute of Scientific and Technical Information of China (English)

    ZHANG Long-qiang; TIAN Nai-yuan; ZHANG Jin; XU An-jun

    2008-01-01

    Based on the requirement of compactivity, continuity, and high efficiency, and taking full advantage of cushion capability of flexible parts such as external refining in new generation steel plant, an output model of steel plant was established in terms of matching between BOF and caster. Using this model, the BOF nominal capacity is selected, the caster output and equipment amount are computed, and then the steel plant output is computed.

  12. Determination of the value of glycated hemoglobin HbA1c and fructosamine in assessing the risk of perioperative complications after cardiac surgery in patients with type 2 diabetes

    Science.gov (United States)

    Wróbel, Marta; Rokicka, Dominika; Szymborska-Kajanek, Aleksandra; Foremny, Jerzy; Nadziakiewicz, Paweł; Zembala, Marian; Strojek, Krzysztof

    2016-01-01

    Introduction Patients with diabetes have a worse postoperative course and longer length of hospital stay after surgery. A good indicator of proper long-term (3 months) glycemic control is glycated hemoglobin (HbA1c), and fructosamine in the short term (2–3 weeks). Aim To determine the degree of glycemic control evaluated preoperatively by HbA1c and/or fructosamine influence on the postoperative course of patients with diabetes undergoing coronary artery bypass grafting (CABG) in 2014–2015. Material and methods Before the operation HbA1c (N < 7.0) and fructosamine (N < 280 µmol/l) were measured and depending on the results the respondents were divided into 4 groups: group I (n = 46) – normal both parameters; group II (n = 22) – high both values; group III (n = 4) – normal fructosamine/HbA1c high; group IV (n = 33) – high HbA1c/fructosamine normal. Statistical analysis was performed using the t-test assuming p < 0.05 to be statistically significant. Results One hundred and five patients were treated by CABG/OPCAB (39 female, 66 males). The mean age was 65.7 ±7.3, HbA1c: 7.23 ±1.2%, fructosamine: 261.8 ±43.8. There was no difference in the incidence of other postoperative complications between the two groups. Conclusions Glycated hemoglobin and fructosamine levels to a similar extent define the risk of perioperative complications in patients undergoing cardiac surgery. In patients in whom there is a need to quickly compensate for elevated blood glucose consider enabling determination of fructosamine. PMID:28096825

  13. 脉搏指示连续心排血量技术对压力与容量控制模式机械通气容量参数的影响%Influence of pulse indicator continuous cardiac output in monitoring on the volume parameters of different tidal volume under pressure control ventilation mode and volume-controlled ventilation mode in sheep

    Institute of Scientific and Technical Information of China (English)

    李军; 高心晶; 高艳颖; 卫俊涛; 秦英智

    2010-01-01

    Objective To compare the influence of pulse indicator continuous cardiac output(PiCCO)in monitoring tidal volume(V_T)under pressure control ventilation mode and volume-controlled ventilation mode in sheep.Methods After anesthesia and tracheotomy,5 sheep,which were apneic and receiving mechanical ventilation.Twenty minutes later,central venous pressure(CVP)and cardiac function were monitored with different selected V_T levels of 6,10,15,20 ml/kg under bi-level positive airway pressure (BiPAP)mode by changing the pressure of inspiration,or under the synchronized intermittent mandatory ventilation(SIMV)mode with the same ventilation conditions.Results In both modes,the increase in V_T led to an decrease of cardiac index(CI)and intrathoracic blood volume index(ITBVI),reaching a statistically significant difference at 15 ml/kg[SIMV mode:CI(3.94±1.03)L·min~(-1)·m~(-2),ITBVI (707±105)ml/m2;BiPAP mode:CI(4.11±1.11)L·min-1±m-2,ITBVI(715±122)ml/m2]and 20 ml/kg[SIMV mode:CI(3.87±1.04)L·min~(-1)·m~(-2),ITBVI(705±116)ml/m2;BiPAP mode:CI (3.64±0.96)L·min~(-1)·m~(-2),ITBVI(694±114)ml/m2]compared with 6 ml/kg[SIMV mode:CI (4.96±1.58)L·min~(-1)·m~(-2),ITBVI(811±169)ml/m2;BiPAP mode:CI(5.67±1.96)L·min~(-1)·m~(-2),ITBVI(8234-182)ml/m~2,all P<0.05];an increase in systemic vascular resistance index(SVRI)and mean airway pressure(Pmean)at 15 ml/kg[SIMV mode:SVRI(237.64±6.2)kPa·s~(-1)·L~(-1),Pmean(14.0±3.2)cm H2O(1 cm H2O=0.098 kPa);BiPAP mode:SVRI(230.8±32.9)kPa·s~(-1)·L~(-1),Pmean(13.0±2.2)cm H_2O]and 20 ml/kg[SIMV mode:SVRI(253.1±76.7)kPa·s~(-1)·L~(-1),Pmean(18.2±4.8)cm H_2O;BiPAP mode:SVRI(246.7±48.8)kPa·s~(-1)·L~(-1),Pmean(16.8±3.3)cm H_2O]compared with 6 ml/kg[SIMV mode:SVRI(184.8±47.5)kPa·s~(-1)·L~(-1);Pmean(8.8±1.6)cm H_2O;BiPAP mode:SVRI(184.5±51.5)kPa·s~(-1)·L~(-1),Pmean(8.6±0.5)cm H_2O,all P<0.05];but there was no significant effects on CVP,heart rate(HR),mean blood pressure(MBP).There was no significant difference of CI

  14. Application Value of Milrinone in the Treatment of Rheumatic Valvular Heart Disease With Cardiac Insufifciency%探讨米力农治疗风湿性心脏瓣膜病心功能不全中的应用价值

    Institute of Scientific and Technical Information of China (English)

    张磊

    2015-01-01

    目的 探讨米力农治疗风湿性心脏瓣膜病心功能不全的应用价值.方法 将120例风湿性心脏瓣膜病患者随机分为对照组和治疗组,每组60例,其中对照组实施常规治疗,治疗组在对照组基础上加用米力农,评估两组患者的心功能,测定心脏指数.结果 治疗组总有效率明显高于对照组,差异具有统计学意义(P<0.05);心排量、射血分数、心脏指数均优于对照组,各指标差异具有统计学意义(P<0.05).结论米力农治疗风湿性心脏瓣膜病心功能不全效果显著,不良反应少.%Objective To explore the therapeutic effect of milrinone for rheumatic valvular heart disease with cardiac insufficiency. Methods 120 cases were divided randomly into two groups of 60 cases each, the therapeutic group were given add-on milrinone by intravenous drip based on conventional therapy while control group were only given conventional therapy. Results The total effective rate of the therapeutic group was higher than control group (P < 0.05) . The cardiac output, cardiac index and ejection fraction in the therapeutic group had obviously increased, there was a significant difference compared with control group (P < 0.05). Conclusion Milrinone are effective and safe drugs for rheumatic valvular heart disease with cardiac insufifciency.

  15. In Vitro Study of Influence of Mimic Cardiac Rate on Hydrodynamics of the Different Mechanical Cardiac Valve Prostheses

    Institute of Scientific and Technical Information of China (English)

    CHU Yin-ping; CHENG Jin-lian; CHEN Ru-kun; FAN Yu-bo; PU Fang

    2005-01-01

    Objective:To assess the influence of mimic cardiac rate on hydrodynamics of the different mechanical prosthetic cardiac valves. Methods: US-made CarboMedics bileaflet valve and China-made Jiuling bileaflet valve and C-L tilting disc valve have been tested in a pulsatile flow simulator in the aortic position. The testing condition was set at the mimic cardiac rate of 55 beats/min,75 beats/min,100beats/min and a constant mimic cardiac output of 4L/min. The mean pressure differences (△P) ,leakage volumes (LEV) and closing volumes (CLV) across each valve,and the effective orifice areas(EOA) have been analyzed. Results:Within the range of physiology,the △P,LEV and CLV were falling as the increasing of mimic cardiac rate,and the extent of variance was larger. The EOA was increasing with the increase of the mimic cardiac rate. It is a different response as the altering of the cardiac rate for the different type of the mechanical prosthetic cardiac valves.Conclusions:The change of the mimic cardiac rate can affect the hydrodynamics of the mechanical prosthetic cardiac valves. The hydrodynamics of the bileaflet valve prosthesis is better than the tilting disc valve.

  16. Avaliação da correlação entre o dióxido de carbono expirado e o débito cardíaco em pacientes submetidos à cirurgia cardíaca com circulação extracorpórea Evaluación de la correlación entre el dióxido de carbono expirado y el débito cardíaco en pacientes sometidos a la cirugía cardíaca con circulación extracorpórea Correlation between end-tidal carbon dioxide levels and cardiac output during cardiac surgery with cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Karina Takesaki Miyaji

    2004-10-01

    reflects pulmonary blood perfusion, thus cardiac output (CO. This study aimed at evaluating the correlation between P ET CO2 levels and CO during cardiac surgery with cardiopulmonary bypass (CPB. METHODS: Participated in this study 25 patients submitted to coronary artery bypass grafting (CABG with CPB. End-tidal CO2 monitoring started after tracheal intubation. Cardiac output was determined by thermodilution with pulmonary artery catheter (Swan-Ganz. Carbon dioxide partial blood pressure (PaCO2 was obtained with arterial blood gases analysis. Studied parameters were evaluated in the following moments: immediately after general anesthesia induction, before cardiopulmonary bypass, at cardiopulmonary bypass completion and at surgery completion. RESULTS: Statistical analysis has not shown correlation between P ET CO2 and CO2, or between P ET CO2-PaCO2 gradient (Ga-eCO2 and CO. There has been correlation between P ET CO2, Ga-eCO2 and CO values variation as compared to baseline values before CPB, with loss of correlation after CPB until surgery completion. CONCLUSIONS: In this study, where patients submitted to cardiac surgery with CPB were evaluated, ventilation/perfusion changes throughout the procedure might have been the factors determining decreased correlation between cardiac output and end tidal CO2.

  17. Cardiac tamponade (image)

    Science.gov (United States)

    Cardiac tamponade is a condition involving compression of the heart caused by blood or fluid accumulation in the space ... they cannot adequately fill or pump blood. Cardiac tamponade is an emergency condition that requires hospitalization.

  18. What Is Cardiac Rehabilitation?

    Science.gov (United States)

    ANSWERS by heart Treatments + Tests What Is Cardiac Rehabilitation? A cardiac rehabilitation (rehab) program takes place in a hospital or ... special help in making lifestyle changes. During your rehabilitation program you’ll… • Have a medical evaluation to ...

  19. Neurons within the same network independently achieve conserved output by differentially balancing variable conductance magnitudes.

    Science.gov (United States)

    Ransdell, Joseph L; Nair, Satish S; Schulz, David J

    2013-06-12

    Biological and theoretical evidence suggest that individual neurons may achieve similar outputs by differentially balancing variable underlying ionic conductances. Despite the substantial amount of data consistent with this idea, a direct biological demonstration that cells with conserved output, particularly within the same network, achieve these outputs via different solutions has been difficult to achieve. Here we demonstrate definitively that neurons from native neural networks with highly similar output achieve this conserved output by differentially tuning underlying conductance magnitudes. Multiple motor neurons of the crab (Cancer borealis) cardiac ganglion have highly conserved output within a preparation, despite showing a 2-4-fold range of conductance magnitudes. By blocking subsets of these currents, we demonstrate that the remaining conductances become unbalanced, causing disparate output as a result. Therefore, as strategies to understand neuronal excitability become increasingly sophisticated, it is important that such variability in excitability of neurons, even among those within the same individual, is taken into account.

  20. Ischemic Colitis after Cardiac Surgery: Can We Foresee the Threat?

    Science.gov (United States)

    Arif, Rawa; Farag, Mina; Zaradzki, Marcin; Reissfelder, Christoph; Pianka, Frank; Bruckner, Thomas; Kremer, Jamila; Franz, Maximilian; Ruhparwar, Arjang; Szabo, Gabor; Beller, Carsten J.; Karck, Matthias; Kallenbach, Klaus; Weymann, Alexander

    2016-01-01

    Introduction Ischemic colitis (IC) remains a great threat after cardiac surgery with use of extracorporeal circulation. We aimed to identify predictive risk factors and influence of early catecholamine therapy for this disease. Methods We prospectively collected and analyzed data of 224 patients, who underwent laparotomy due to IC after initial cardiac surgery with use of extracorporeal circulation during 2002 and 2014. For further comparability 58 patients were identified, who underwent bypass surgery, aortic valve replacement or combination of both. Age ±5 years, sex, BMI ± 5, left ventricular function, peripheral arterial disease, diabetes and urgency status were used for match-pair analysis (1:1) to compare outcome and detect predictive risk factors. Highest catecholamine doses during 1 POD were compared for possible predictive potential. Results Patients’ baseline characteristics showed no significant differences. In-hospital mortality of the IC group with a mean age of 71 years (14% female) was significantly higher than the control group with a mean age of 70 (14% female) (67% vs. 16%, p<0.001). Despite significantly longer bypass time in the IC group (133 ± 68 vs. 101 ± 42, p = 0.003), cross-clamp time remained comparable (64 ± 33 vs. 56 ± 25 p = 0.150). The majority of the IC group suffered low-output syndrome (71% vs. 14%, p<0.001) leading to significant higher lactate values within first 24h after operation (55 ± 46 mg/dl vs. 31 ± 30 mg/dl, p = 0.002). Logistic regression revealed elevated lactate values to be significant predictor for colectomy during the postoperative course (HR 1.008, CI 95% 1.003–1.014, p = 0.003). However, Receiver Operating Characteristic Curve calculates a cut-off value for lactate of 22.5 mg/dl (sensitivity 73% and specificity 57%). Furthermore, multivariate analysis showed low-output syndrome (HR 4.301, CI 95% 2.108–8.776, p<0.001) and vasopressin therapy (HR 1.108, CI 95% 1.012–1.213, p = 0.027) significantly

  1. Cardiac sodium channelopathies

    NARCIS (Netherlands)

    Amin, A.S.; Asghari-Roodsari, A.; Tan, H.L.

    2010-01-01

    Cardiac sodium channel are protein complexes that are expressed in the sarcolemma of cardiomyocytes to carry a large inward depolarizing current (I-Na) during phase 0 of the cardiac action potential. The importance of I-Na for normal cardiac electrical activity is reflected by the high incidence of

  2. The Western Denmark Cardiac Computed Tomography Registry

    DEFF Research Database (Denmark)

    Nielsen, Lene Hüche; Nørgaard, Bjarne Linde; Tilsted, Hans Henrik;

    2015-01-01

    -CCTR, showed that coronary CT angiographies accounted for only 23% of all nonregistered cardiac CTs, indicating >90% completeness of coronary CT angiographies in the WDHR-CCTR. The completeness of individual variables varied substantially (range: 0%-100%), but was >85% for more than 70% of all variables. Using......BACKGROUND: As a subregistry to the Western Denmark Heart Registry (WDHR), the Western Denmark Cardiac Computed Tomography Registry (WDHR-CCTR) is a clinical database established in 2008 to monitor and improve the quality of cardiac computed tomography (CT) in Western Denmark. OBJECTIVE: We...... expected numbers; and 4) positive predictive values as well as negative predictive values of 19 main patient and procedure variables. RESULTS: By December 31, 2012, almost 22,000 cardiac CTs with up to 40 variables for each procedure have been registered. Of these, 87% were coronary CT angiography...

  3. Correlation Degree and Correlation Coefficient of Multi- Output Functions

    Institute of Scientific and Technical Information of China (English)

    JU Gui-zhi; ZHAO Ya-qun

    2005-01-01

    We present definitions of the correlation degree and correlation coefficient of multi-output functions. Two relationships about the correlation degree of multi-output functions are proved. One is between the correlation degree and independency,the other is between the correlation degree and balance. Especially the paper discusses the correlation degree of affine multioutput functions. We demonstrate properties of the correlation coefficient of multi-output functions. One is the value range of the correlation coefficient, one is the relationship between the correlation coefficient and independency, and another is the sufficient and necessary condition that two multi-output functions are equivalent to each other.

  4. Resolution of abnormal cardiac MRI T2 signal following immune suppression for cardiac sarcoidosis.

    Science.gov (United States)

    Crouser, Elliott D; Ruden, Emily; Julian, Mark W; Raman, Subha V

    2016-08-01

    Cardiac MR (CMR) with late gadolinium enhancement is commonly used to detect cardiac damage in the setting of cardiac sarcoidosis. The addition of T2 mapping to CMR was recently shown to enhance cardiac sarcoidosis detection and correlates with increased cardiac arrhythmia risk. This study was conducted to determine if CMR T2 abnormalities and related arrhythmias are reversible following immune suppression therapy. A retrospective study of subjects with cardiac sarcoidosis with abnormal T2 signal on baseline CMR and a follow-up CMR study at least 4 months later was conducted at The Ohio State University from 2011 to 2015. Immune suppression treated participants had a significant reduction in peak myocardial T2 value (70.0±5.5 vs 59.2±6.1 ms, pretreatment vs post-treatment; p=0.017), and 83% of immune suppression treated subjects had objective improvement in cardiac arrhythmias. Two subjects who had received inadequate immune suppression treatment experienced progression of cardiac sarcoidosis. This report indicates that abnormal CMR T2 signal represents an acute inflammatory manifestation of cardiac sarcoidosis that is potentially reversible with adequate immune suppression therapy.

  5. Atrophic cardiac remodeling induced by taurine deficiency in Wistar rats.

    Directory of Open Access Journals (Sweden)

    Mariele Castilho Pansani

    Full Text Available INTRODUCTION: Micronutrient deficiency is observed in heart failure patients. Taurine, for example, represents 50% of total free amino acids in the heart, and in vivo studies have linked taurine deficiency with cardiomyopathy. METHODS: Thirty-four male Wistar rats (body weight = 100 g were weighed and randomly assigned to one of two groups: Control (C or taurine-deficient (T (-. Beta-alanine at a concentration of 3% was added to the animals' water to induce taurine deficiency in the T (- group. On day 30, the rats were individually submitted to echocardiography; morphometrical and histopathological evaluation and metalloproteinase activity, oxidative stress and inflammation evaluation were performed. Tissue samples were collected to determine the taurine concentration in the heart. RESULTS: Taurine deficiency led to decreases in: ventricular wall thickness, left ventricle dry weight, myocyte sectional area, left ventricle posterior wall thickness and ventricular geometry. With regard to heart function, the velocity of the A wave, the ratio between the E and A wave, the ejection fraction, fractional shortening and cardiac output values were decreased in T (- rats, suggesting abnormal diastolic and systolic function. Increased fibrosis, inflammation and increased activation of metalloproteinases were not observed. Oxidative stress was increased in deficient animals. CONCLUSIONS: These data suggest that taurine deficiency promotes structural and functional cardiac alterations with unique characteristics.

  6. Evaluation of a novel integrated sensor system for synchronous measurement of cardiac vibrations and cardiac potentials.

    Science.gov (United States)

    Chuo, Yindar; Tavakolian, Kouhyar; Kaminska, Bozena

    2011-08-01

    The measurement of human body vibrations as a result of heart beating, simultaneously with cardiac potentials have been demonstrated in past studies to bring additional value to diagnostic cardiology through the detection of irregularities in the mechanical movement of the heart. The equipment currently available to the medical community is either large and bulky or difficult to synchronize. To address this problem, a novel integrated sensor system has been developed to record cardiac vibration and cardiac potential simultaneously and synchronously from a single compact site on the chest. The developed sensor system is lightweight, small in size, and suitable for mounting on active moving patients. The sensor is evaluated for its adequacy in measuring cardiac vibrations and potentials. In this evaluation, 45 independent signal recording are studied from 15 volunteers, and the morphology of the recorded signals are analyzed qualitatively (by visual inspection) and quantitatively (by computational methods) against larger devices used in established cardiac vibration studies (reference devices). It is found that the cardiac vibration signals acquired by the integrated sensor has 92.37% and 81.76% identically identifiable systolic and diastolic cardiac complexes, respectively, when compared to the cardiac vibration signals recorded simultaneously from the reference device. Further, the cardiac potential signals acquired by the integrated sensor show a high correlation coefficient of 0.8912 and a high estimated signal-to-noise-ratio of 22.00 dB when compared to the reference electrocardiograph (non-standard leads) acquired through a common clinical machine. The results suggest that the tiny, wearable, integrated sensor system that synchronously measures cardiac vibrations and cardiac potentials may be practical for use as an alternative or assistive cardiac diagnostic tool.

  7. Multi-output differential technologies

    Science.gov (United States)

    Bidare, Srinivas R.

    1997-01-01

    A differential is a very old and proven mechanical device that allows a single input to be split into two outputs having equal torque irrespective of the output speeds. A standard differential is capable of providing only two outputs from a single input. A recently patented multi-output differential technology known as `Plural-Output Differential' allows a single input to be split into many outputs. This new technology is the outcome of a systematic study of complex gear trains (Bidare 1992). The unique feature of a differential (equal torque at different speeds) can be applied to simplify the construction and operation of many complex mechanical devices that require equal torque's or forces at multiple outputs. It is now possible to design a mechanical hand with three or more fingers with equal torque. Since these finger are powered via a differential they are `mechanically intelligent'. A prototype device is operational and has been used to demonstrate the utility and flexibility of the design. In this paper we shall review two devices that utilize the new technology resulting in increased performance, robustness with reduced complexity and cost.

  8. Débito cardíaco diminuído: revisão sistemática das características definidoras Débito cardíaco disminuído: revisión sistemática de las características definidoras Decreased cardiac output: a systematic review of the defining characteristics

    Directory of Open Access Journals (Sweden)

    Vanessa de Souza

    2011-01-01

    explorada. Se constató la importancia del examen físico, la utilización de técnicas menos invasivas y la necesidad de revisar las características definidoras propuestas a fin de proporcionar claridad y objetividad en la identificación de ese diagnóstico de enfermeríaOBJECTIVES: To characterize the scientific articles related to the NANDA-I nursing diagnosis, decreased cardiac output. Verify those articles that describe the behavior of the defining characteristics of this diagnosis, identifying those that occur with the highest frequency. METHODS: A systematic review of literature published between the years 1985 - 2008 was conducted, using the following databases: Lilacs, SciELO, EMBASE, Medline, Pubmed and Cochrane. RESULTS: The sample included 13 articles which identified 50 defining characteristics. Ten characteristics were noted to occur with high frequency: altered heart rate/rhythm, dyspnea, labile blood pressure, rales, oliguria / anuria, edema, cold skin, fatigue / weakness, decreased peripheral pulses and decreased peripheral perfusion. CONCLUSION: This subject has not been explored in depth in the literature. The importance of physical examination, the use of less invasive techniques, and the need to review the proposed defining characteristics to provide clarity and objectivity in the identification of this nursing diagnosis was identified

  9. 脉波指示剂连续心排血量监测技术在早期目标导向治疗中的临床作用分析%Pulse Indicator Continuous Cardiac Output for Hemodynamics Monitoring in Patients with Septic Shock

    Institute of Scientific and Technical Information of China (English)

    陈刚; 王标; 郭小芙

    2014-01-01

    Objective To investigate the application of pulse index continuous cardiac output (PiCCO) in patients with septic shock.MethodsSixty patients with septic shock were randomly divided into two groups: routine monitoring group and PiCCO monitoring group, with 30 patients in each group. The rate of reaching standard of early goal directed therapy (EGDT) was observed after treatment for 6, 24 and 48 hours. In addition, blood lactic acid, central venous oxygen saturation (ScvO2), central venous pressure (CVP), mean arterial pressure (MAP) and urine volume were determined after treatment for 6, 24 and 48 hours, and positive fluid balance amount and dosages of dopamine and dobutamine were measured after treatment for 6, 24 and 48 hours. Mortality was observed in the patients of both groups.Results After treatment for 6, 24 and 48 hours, in PiCCO monitoring group, ScvO2 signifi cantly increased, blood lactic acid level, positivefl uid balance amount, dosages of dopamine and dobutamine signifi cantly decreased compared with routine monitoring group (P<0.05). The rate of reaching standard of EGDT in PiCCO monitoring group was signifi cantly higher than that in routine monitoring group after treatment for 6, 24 hours. There also was difference in mortality between the two groups (P<0.05).Conclusion PiCCO monitor has an important clinical guide signifi cance for the resuscitation of septic shock, which can help to reach the fast and effective treatment target, improve septic shock, avoid the damage of blindfl uid infusion, provide fast and right treatment evidence. So it is worth being spread in clinic treatment.%目的:探讨脉波指示剂连续心排血量监测(PiCCO)技术在脓毒性休克患者早期目标导向治疗(EGDT)中的临床指导价值。方法将60例脓毒性休克患者按随机数字表法分为常规监测组和PiCCO监测组各30例,PiCCO监测组在PiCCO技术指导下行EGDT,常规监测组患者放置中心静脉导管和桡动脉导

  10. Mechanisms of cardiac pain.

    Science.gov (United States)

    Foreman, Robert D; Garrett, Kennon M; Blair, Robert W

    2015-04-01

    Angina pectoris is cardiac pain that typically is manifested as referred pain to the chest and upper left arm. Atypical pain to describe localization of the perception, generally experienced more by women, is referred to the back, neck, and/or jaw. This article summarizes the neurophysiological and pharmacological mechanisms for referred cardiac pain. Spinal cardiac afferent fibers mediate typical anginal pain via pathways from the spinal cord to the thalamus and ultimately cerebral cortex. Spinal neurotransmission involves substance P, glutamate, and transient receptor potential vanilloid-1 (TRPV1) receptors; release of neurokinins such as nuclear factor kappa b (NF-kb) in the spinal cord can modulate neurotransmission. Vagal cardiac afferent fibers likely mediate atypical anginal pain and contribute to cardiac ischemia without accompanying pain via relays through the nucleus of the solitary tract and the C1-C2 spinal segments. The psychological state of an individual can modulate cardiac nociception via pathways involving the amygdala. Descending pathways originating from nucleus raphe magnus and the pons also can modulate cardiac nociception. Sensory input from other visceral organs can mimic cardiac pain due to convergence of this input with cardiac input onto spinothalamic tract neurons. Reduction of converging nociceptive input from the gallbladder and gastrointestinal tract can diminish cardiac pain. Much work remains to be performed to discern the interactions among complex neural pathways that ultimately produce or do not produce the sensations associated with cardiac pain.

  11. The Z scores value of cardiac structure by preoperative echocardiography in children with tetralogy of Fallot%法洛四联症患儿手术前超声心动图Z值研究

    Institute of Scientific and Technical Information of China (English)

    陈伟玲; 夏焙; 于红奎; 许娜

    2015-01-01

    Objective To evaluate the value and clinical application of cardiac structure Z scores in children with preoperative tetralogy of Fallot (TOF) by echocardiography. Methods Considering the result of 31 patients who underwent echocardiography in Shenzhen Children’s Hospital before TOF repair from January 2011 to September 2013, the median age was 10 months (range:3 days to 14 years). Other 31 normal children were selected as normal control group with age-and sex-matched, the median age was 10 months (range: 6 days to 13 years). Echocardiographic measurements included the diameter of right ventricular outflow tract (RVOT), pulmonary valve diameter (PVD), left pulmonary artery diameter (LPAD), right pulmonary artery diameter (RPAD), pulmonary valve peak velocity (PV-Vmax), tricuspid annulus diameter (TVD), mitral annulus diameter (MAD), left ventricular end-diastolic volume (LVEDV) and left ventricular mass (LVmass). Shenzhen Children’s Hospital pediatric echocardiography normal reference values and the regression equation are applied to obtain the forecast average, and using the Z-score formula into the standard value (Z=[M-y]/ MSE ). Results There was no significant difference in body surface area between the TOF group and control group (P>0.05). Compared with control group, the true value of RVOT reduced significantly in TOF group, its Z-score showed negative values increase (-4.87±1.86 vs 0.33±0.93, t=-13.90, P0.05), but the Z scores of TOF were significantly reduced than the control group (0.25±0.78 vs 0.76±0.65, t=-2.75;-0.92±1.94 vs 0.03±1.01, t=-2.41;-0.83±1.59 vs 0.67±0.69, t=-4.71; all P0.05). For the Z scores of PV-Vmax, there were no significant difference between transannular patch surgery and pulmonary valve-sparing repair (8.58±1.20 vs 8.12±1.16, t=1.07, P>0.05). Conclusions The Z scores value of cardiac structure can be used in quantitative analysis of RVOT obstruction and development of left ventricular backward of TOF. The Z score of

  12. Verification of hourly forecasts of wind turbine power output

    Energy Technology Data Exchange (ETDEWEB)

    Wegley, H.L.

    1984-08-01

    A verification of hourly average wind speed forecasts in terms of hourly average power output of a MOD-2 was performed for four sites. Site-specific probabilistic transformation models were developed to transform the forecast and observed hourly average speeds to the percent probability of exceedance of an hourly average power output. (This transformation model also appears to have value in predicting annual energy production for use in wind energy feasibility studies.) The transformed forecasts were verified in a deterministic sense (i.e., as continuous values) and in a probabilistic sense (based upon the probability of power output falling in a specified category). Since the smoothing effects of time averaging are very pronounced, the 90% probability of exceedance was built into the transformation models. Semiobjective and objective (model output statistics) forecasts were made compared for the four sites. The verification results indicate that the correct category can be forecast an average of 75% of the time over a 24-hour period. Accuracy generally decreases with projection time out to approx. 18 hours and then may increase due to the fairly regular diurnal wind patterns that occur at many sites. The ability to forecast the correct power output category increases with increasing power output because occurrences of high hourly average power output (near rated) are relatively rare and are generally not forecast. The semiobjective forecasts proved superior to model output statistics in forecasting high values of power output and in the shorter time frames (1 to 6 hours). However, model output statistics were slightly more accurate at other power output levels and times. Noticeable differences were observed between deterministic and probabilistic (categorical) forecast verification results.

  13. Full Static Output Feedback Equivalence

    Directory of Open Access Journals (Sweden)

    Aristotle G. Yannakoudakis

    2013-01-01

    Full Text Available We present a constructive solution to the problem of full output feedback equivalence, of linear, minimal, time-invariant systems. The equivalence relation on the set of systems is transformed to another on the set of invertible block Bezout/Hankel matrices using the isotropy subgroups of the full state feedback group and the full output injection group. The transformation achieving equivalence is calculated solving linear systems of equations. We give a polynomial version of the results proving that two systems are full output feedback equivalent, if and only if they have the same family of generalized Bezoutians. We present a new set of output feedback invariant polynomials that generalize the breakaway polynomial of scalar systems.

  14. Stimulating endogenous cardiac regeneration

    Directory of Open Access Journals (Sweden)

    Amanda eFinan

    2015-09-01

    Full Text Available The healthy adult heart has a low turnover of cardiac myocytes. The renewal capacity, however, is augmented after cardiac injury. Participants in cardiac regeneration include cardiac myocytes themselves, cardiac progenitor cells, and peripheral stem cells, particularly from the bone marrow compartment. Cardiac progenitor cells and bone marrow stem cells are augmented after cardiac injury, migrate to the myocardium, and support regeneration. Depletion studies of these populations have demonstrated their necessary role in cardiac repair. However, the potential of these cells to completely regenerate the heart is limited. Efforts are now being focused on ways to augment these natural pathways to improve cardiac healing, primarily after ischemic injury but in other cardiac pathologies as well. Cell and gene therapy or pharmacological interventions are proposed mechanisms. Cell therapy has demonstrated modest results and has passed into clinical trials. However, the beneficial effects of cell therapy have primarily been their ability to produce paracrine effects on the cardiac tissue and recruit endogenous stem cell populations as opposed to direct cardiac regeneration. Gene therapy efforts have focused on prolonging or reactivating natural signaling pathways. Positive results have been demonstrated to activate the endogenous stem cell populations and are currently being tested in clinical trials. A potential new avenue may be to refine pharmacological treatments that are currently in place in the clinic. Evidence is mounting that drugs such as statins or beta blockers may alter endogenous stem cell activity. Understanding the effects of these drugs on stem cell repair while keeping in mind their primary function may strike a balance in myocardial healing. To maximize endogenous cardiac regeneration,a combination of these approaches couldameliorate the overall repair process to incorporate the participation ofmultiple cell players.

  15. Functional and Hemodynamic Cardiac Determinants of Exercise Capacity in Patients With Systolic Heart Failure

    NARCIS (Netherlands)

    Hummel, Yoran M.; Bugatti, Silvia; Damman, Kevin; Willemsen, Suzan; Hartog, Jasper W. L.; Metra, Marco; Sipkens, Johannes S.; van Veldhuisen, Dirk J.; Voors, Adriaan A.

    2012-01-01

    Decreased exercise capacity is the main symptom in patients with heart failure (HF). We assessed the association among noninvasively determined maximal cardiac output at exercise, systolic and diastolic cardiac functions at rest, and peak oxygen uptake (pVO(2)) exercise capacity in patients with con

  16. Cardiac tissue engineering: state of the art.

    Science.gov (United States)

    Hirt, Marc N; Hansen, Arne; Eschenhagen, Thomas

    2014-01-17

    The engineering of 3-dimensional (3D) heart muscles has undergone exciting progress for the past decade. Profound advances in human stem cell biology and technology, tissue engineering and material sciences, as well as prevascularization and in vitro assay technologies make the first clinical application of engineered cardiac tissues a realistic option and predict that cardiac tissue engineering techniques will find widespread use in the preclinical research and drug development in the near future. Tasks that need to be solved for this purpose include standardization of human myocyte production protocols, establishment of simple methods for the in vitro vascularization of 3D constructs and better maturation of myocytes, and, finally, thorough definition of the predictive value of these methods for preclinical safety pharmacology. The present article gives an overview of the present state of the art, bottlenecks, and perspectives of cardiac tissue engineering for cardiac repair and in vitro testing.

  17. Measuring temporal resolution of cardiac CT reconstructions

    Science.gov (United States)

    Matthews, David; Heuscher, Dominic

    2005-04-01

    Multi-slice CT today is capable of imaging the heart with excellent temporal resolution. Algorithms have been developed to perform reconstructions combining data from multiple cardiac cycles. This paper presents a simulation phantom that enables a direct measurement of the actual temporal resolution achieved by these algorithms. This is not only useful for assessing the temporal resolution but also for validating the algorithms themselves. A simulation phantom was developed that consists of a 20 cm. diameter water phantom containing an array of cylinders whose intensities are pulsed for various durations ranging from 10 msec. to 250 msec. The intensity varied between the background value of water (0 HU) and 800 HU. By measuring the nominal attenuation value at the center of each cylinder, a curve can be derived representing the response over the given temporal range. A temporal resolution representing the FWHM value is determined based on the half-max value of this curve. Reconstructions were performed using a multi-cycle cardiac algorithm described previously in the literature. The measured FWHM values agree quite well to the temporal resolution predicted by the cardiac algorithm itself. Even the variation along the longitudinal axis can be accounted for by the predicted values. A simulated phantom can be used to accurately assess the temporal resolution of cardiac reconstruction algorithms. Excellent agreement was achieved between the predicted and measured temporal resolution values for the multi-cycle algorithm used in this study.

  18. Marketing cardiac CT programs.

    Science.gov (United States)

    Scott, Jason

    2010-01-01

    There are two components of cardiac CT discussed in this article: coronary artery calcium scoring (CACS) and coronary computed tomography angiography (CCTA).The distinctive advantages of each CT examination are outlined. In order to ensure a successful cardiac CT program, it is imperative that imaging facilities market their cardiac CT practices effectively in order to gain a competitive advantage in this valuable market share. If patients receive quality care by competent individuals, they are more likely to recommend the facility's cardiac CT program. Satisfied patients will also be more willing to come back for any further testing.

  19. Comparação dos efeitos da dobutamina e da milrinona sobre a hemodinâmica e o transporte de oxigênio em pacientes submetidos à cirurgia cardíaca com baixo débito cardíaco após indução anestésica Comparación de los efectos de la dobutamina y de la milrinona sobre la hemodinámica y el transporte de oxígeno en pacientes sometidos a cirugía cardiaca con bajo débito cardiaco después de inducción anestésica Comparison of the effects of dobutamine and milrinone on hemodynamic parameters and oxygen supply in patients undergoing cardiac surgery with low cardiac output after anesthetic induction

    Directory of Open Access Journals (Sweden)

    Maria José Carvalho Carmona

    2010-06-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: Diversas classes de fármacos inotrópicos, com efeitos hemodinâmicos diferentes, são utilizadas no tratamento do baixo débito cardíaco em pacientes com disfunção sistólica submetidos a procedimento cirúrgico cardíaco. O objetivo deste estudo foi comparar o efeito da dobutamina e da milrinona sobre a hemodinâmica e o transporte de oxigênio nessa população de pacientes. MÉTODO: Após aprovação do Comitê de Ética institucional e obtenção do consentimento escrito pós-informado, 20 pacientes submetidos à cirurgia cardíaca e com índice cardíaco JUSTIFICATIVA Y OBJETIVOS: Diversas clases de fármacos inotrópicos con efectos hemodinámicos diferentes, se usan en el tratamiento del bajo débito cardíaco en pacientes con disfunción sistólica sometidos al procedimiento quirúrgico cardíaco. El objetivo de este estudio, fue comparar el efecto de la dobutamina y de la milrinona sobre la hemodinámica y el transporte de oxígeno en esa población de pacientes. MÉTODO: Después de la aprobación del Comité de Ética institucional y de la obtención del consentimiento informado, 20 pacientes sometidos a la cirugía cardíaca y con índice cardíaco BACKGROUND AND OBJECTIVES: Several classes of inotropic drugs with different hemodynamic effects are used in the treatment of low cardiac output in patients with diastolic dysfunction undergoing cardiac surgery. The objective of the present study was to compare the effects of dobutamine and milrinone on hemodynamic parameters and oxygen supply in this population of patients. METHODS: After approval by the Ethics Committee of the institution and signing of the informed consent, 20 patients undergoing cardiac surgery with cardiac index < 2 L.min-1.m2 after anesthetic induction and place ment of a pulmonary artery catheter were randomly divided to receive dobutamine 5 µg.kg-1. min-1 (n = 10, or milrinone 0.5 µg.kg-1.min-1 (n = 10. Hemodynamic parameters were

  20. A Fixed-point Technique of Wavelet Transform Base on Bounded Input Bounded Output (BIBO) Plus Value in JPEG2000 Algorithm%JPEG2000算法中基于有界输入有界输出(BIBO)增益控制的小波变换定点实现技术

    Institute of Scientific and Technical Information of China (English)

    张静; 李云松; 郭杰; 王柯俨; 吴成柯

    2012-01-01

    A new efficient technique using the compatible hardware framework to realize the integer 5/3 wavelet transform and 9/7 wavelet transform is proposed. The bit depth of the temp coefficients in the wavelet transform is based on the Bounded Input Bounded Output (BIBO) plus value of 9/7 wavelet transform, at the same time, the quantization value of 9/7 wavelet transform and how to do quantization is decided by BIBO puls value of 5/3 wavelet transform. Finally, both the coefficients of 5/3 wavelet transform and 9/7 wavelet transform are saved in the same memories. The proposed technique not only saves the hardware memory resource and computational complexity of the wavelet transform module, but also saves the hardware memory resource and computational complexity of the bitplane arithmetric coding based on the context module and post-compression rate-distortion optimization module.%该文提出一种在JPEG2000算法中兼容5/3小波变换和9/7小波变换高效硬件定点实现技术.所提出的技术使用9/7提升小波变换的有界输入有界输出(Bounded Input Bounded Output,BIBO)增益来确定小波变换中间值的存储位深,使用5/3提升小波变换的BIBO增益来确定9/7提升小波变换中量化参数的选择方式和量化的实现方式,最终使用同一存储空间来存放定点5/3提升小波变换和定点9/7提升小波变换系数.该文提出的技术不仅大大节省了JPEG2000算法中小波实现模块中的硬件存储资源和算法计算量,而且也节省了后续基于上下文的位平面算术编码模块和率失真优化截取模块的存储资源和算法计算量.

  1. Remote input/output station

    CERN Multimedia

    1972-01-01

    A general view of the remote input/output station installed in building 112 (ISR) and used for submitting jobs to the CDC 6500 and 6600. The card reader on the left and the line printer on the right are operated by programmers on a self-service basis.

  2. World Input-Output Network.

    Science.gov (United States)

    Cerina, Federica; Zhu, Zhen; Chessa, Alessandro; Riccaboni, Massimo

    2015-01-01

    Production systems, traditionally analyzed as almost independent national systems, are increasingly connected on a global scale. Only recently becoming available, the World Input-Output Database (WIOD) is one of the first efforts to construct the global multi-regional input-output (GMRIO) tables. By viewing the world input-output system as an interdependent network where the nodes are the individual industries in different economies and the edges are the monetary goods flows between industries, we analyze respectively the global, regional, and local network properties of the so-called world input-output network (WION) and document its evolution over time. At global level, we find that the industries are highly but asymmetrically connected, which implies that micro shocks can lead to macro fluctuations. At regional level, we find that the world production is still operated nationally or at most regionally as the communities detected are either individual economies or geographically well defined regions. Finally, at local level, for each industry we compare the network-based measures with the traditional methods of backward linkages. We find that the network-based measures such as PageRank centrality and community coreness measure can give valuable insights into identifying the key industries.

  3. Input/output interface module

    Science.gov (United States)

    Ozyazici, E. M.

    1980-01-01

    Module detects level changes in any of its 16 inputs, transfers changes to its outputs, and generates interrupts when changes are detected. Up to four changes-in-state per line are stored for later retrieval by controlling computer. Using standard TTL logic, module fits 19-inch rack-mounted console.

  4. World Input-Output Network.

    Directory of Open Access Journals (Sweden)

    Federica Cerina

    Full Text Available Production systems, traditionally analyzed as almost independent national systems, are increasingly connected on a global scale. Only recently becoming available, the World Input-Output Database (WIOD is one of the first efforts to construct the global multi-regional input-output (GMRIO tables. By viewing the world input-output system as an interdependent network where the nodes are the individual industries in different economies and the edges are the monetary goods flows between industries, we analyze respectively the global, regional, and local network properties of the so-called world input-output network (WION and document its evolution over time. At global level, we find that the industries are highly but asymmetrically connected, which implies that micro shocks can lead to macro fluctuations. At regional level, we find that the world production is still operated nationally or at most regionally as the communities detected are either individual economies or geographically well defined regions. Finally, at local level, for each industry we compare the network-based measures with the traditional methods of backward linkages. We find that the network-based measures such as PageRank centrality and community coreness measure can give valuable insights into identifying the key industries.

  5. Cardiac Procedures and Surgeries

    Science.gov (United States)

    ... Peripheral Artery Disease Venous Thromboembolism Aortic Aneurysm More Cardiac Procedures and Surgeries Updated:Sep 16,2016 If you've had ... degree of coronary artery disease (CAD) you have. Cardiac Procedures and Surgeries Angioplasty Also known as Percutaneous Coronary Interventions [PCI], ...

  6. [Advances in cardiac pacing].

    Science.gov (United States)

    de Carranza, María-José Sancho-Tello; Fidalgo-Andrés, María Luisa; Ferrer, José Martínez; Mateas, Francisco Ruiz

    2012-01-01

    This article contains a review of the current status of remote monitoring and follow-up involving cardiac pacing devices and of the latest developments in cardiac resynchronization therapy. In addition, the most important articles published in the last year are discussed.

  7. Biomaterials for cardiac regeneration

    CERN Document Server

    Ruel, Marc

    2015-01-01

    This book offers readers a comprehensive biomaterials-based approach to achieving clinically successful, functionally integrated vasculogenesis and myogenesis in the heart. Coverage is multidisciplinary, including the role of extracellular matrices in cardiac development, whole-heart tissue engineering, imaging the mechanisms and effects of biomaterial-based cardiac regeneration, and autologous bioengineered heart valves. Bringing current knowledge together into a single volume, this book provides a compendium to students and new researchers in the field and constitutes a platform to allow for future developments and collaborative approaches in biomaterials-based regenerative medicine, even beyond cardiac applications. This book also: Provides a valuable overview of the engineering of biomaterials for cardiac regeneration, including coverage of combined biomaterials and stem cells, as well as extracellular matrices Presents readers with multidisciplinary coverage of biomaterials for cardiac repair, including ...

  8. Mathematical cardiac electrophysiology

    CERN Document Server

    Colli Franzone, Piero; Scacchi, Simone

    2014-01-01

    This book covers the main mathematical and numerical models in computational electrocardiology, ranging from microscopic membrane models of cardiac ionic channels to macroscopic bidomain, monodomain, eikonal models and cardiac source representations. These advanced multiscale and nonlinear models describe the cardiac bioelectrical activity from the cell level to the body surface and are employed in both the direct and inverse problems of electrocardiology. The book also covers advanced numerical techniques needed to efficiently carry out large-scale cardiac simulations, including time and space discretizations, decoupling and operator splitting techniques, parallel finite element solvers. These techniques are employed in 3D cardiac simulations illustrating the excitation mechanisms, the anisotropic effects on excitation and repolarization wavefronts, the morphology of electrograms in normal and pathological tissue and some reentry phenomena. The overall aim of the book is to present rigorously the mathematica...

  9. Predictors for severe cardiac complications after hematopoietic stem cell transplantation.

    Science.gov (United States)

    Sakata-Yanagimoto, M; Kanda, Y; Nakagawa, M; Asano-Mori, Y; Kandabashi, K; Izutsu, K; Imai, Y; Hangaishi, A; Kurokawa, M; Tsujino, S; Ogawa, S; Chiba, S; Motokura, T; Hirai, H

    2004-05-01

    The value of pre-transplant factors for predicting the development of cardiac complications after transplantation has been inconsistent among studies. We analyzed the impact of pre-transplant factors on the incidence of severe cardiac complications in 164 hematopoietic stem cell transplant recipients. We identified eight patients (4.8%) who experienced grade III or IV cardiac complications according to the Bearman criteria. Seven died of cardiac causes a median of 3 days after the onset of cardiac complications. On univariate analysis, both the cumulative dose of anthracyclines and the use of anthracyclines within 60 days before transplantation affected the incidence of severe cardiac complications (P=0.0091 and 0.011). The dissociation of heart rate and body temperature, which reflects "relative tachycardia", was also associated with a higher incidence of cardiac complications (P=0.024). None of the variables obtained by electrocardiography or echocardiography were useful for predicting cardiac complications after transplantation, although the statistical power might not be sufficient to detect the usefulness of ejection fraction. On a multivariate analysis, the cumulative dose of anthracyclines was the only independent significant risk factor for severe cardiac complications. We conclude that the cumulative dose of anthracyclines is the most potent predictor of cardiac complications and the administration of anthracyclines should be avoided within two months before transplantation.

  10. Input-output interactions and optimal monetary policy

    DEFF Research Database (Denmark)

    Petrella, Ivan; Santoro, Emiliano

    2011-01-01

    This paper deals with the implications of factor demand linkages for monetary policy design in a two-sector dynamic general equilibrium model. Part of the output of each sector serves as a production input in both sectors, in accordance with a realistic input–output structure. Strategic...... complementarities induced by factor demand linkages significantly alter the transmission of shocks and amplify the loss of social welfare under optimal monetary policy, compared to what is observed in standard two-sector models. The distinction between value added and gross output that naturally arises...

  11. Analysis of Input and Output Ripples of PWM AC Choppers

    Directory of Open Access Journals (Sweden)

    Pekik Argo Dahono

    2008-11-01

    Full Text Available This paper presents an analysis of input and output ripples of PWM AC choppers. Expressions of input and output current and voltage ripples of single-phase PWM AC choppers are first derived. The derived expressions are then extended to three-phase PWM AC choppers. As input current and output voltage ripples specification alone cannot be used to determine the unique values of inductance and capacitance of the LC filters, an additional criterion based on the minimum reactive power is proposed. Experimental results are included in this paper to show the validity of the proposed analysis method.

  12. Identification of Regional Value-Chain Cluster Based on Input-Output Table: A Case Study of Shanghai%基于投入产出表的区域价值链集群识别研究——以上海为例

    Institute of Scientific and Technical Information of China (English)

    卢戎; 于丽英

    2011-01-01

    区域价值链集群分析是集群分析作为区域经济创新性和竞争优势分析工具的重要表现形式.而区域价值链集群识别是进行区域价值链集群分析的第一步.为了实现区域价值链集群依据经济系统各部门间网络互动联系来确定其核心主导产业及其前后向密切关联产业的识别目标,本文选取了以最大值法和投入产出分析法相结合的区域价值链识别方法.由此进行的识别研究表明,上海共有通信、化工、通专、金属、石油核燃料五类价值链集群,它们通过内部和彼此间的互动交织构成了密切关联的网络,并在很大程度上反映了上海经济系统的核心组成.而相应的经济技术分析表明,通专价值链集群将很有可能在上海大力发展先进制造业的产业结构升级大背景下赶超通信价值链集群而成为新一轮发展的亮点.%Analysis of regional value-chain cluster is one of the important analysis tools of regional economic innovation and competitive advantages. And the identification of regional value-chain cluster is the first step of it. To fulfill the goal of identifying core sector and its closely related ones which compose a regional value-chain cluster based on input-output network, a different identification method has been chosen in this paper with the combination of method of maxima and input-output analysis. According to the results of the case study, there are five regional value-chain clusters in Shanghai, whose core sectors are Manufacture of Communication Equipment, Computers and Other Electronic Equipment(A) , Chemical Industries( B) , Manufacture of General and Special Purpose Machinery(C) , Smelting and Pressing of Metals(D)and Oil Processing, Coking and Nuclear Fuel Processing( E) respectively. The network created by inside and outside interaction among these five value-chain clusters largely covers the core composition of economic system in Shanghai. And the following

  13. Distinct properties and metabolic mechanisms of postresuscitation myocardial injuries in ventricular fibrillation cardiac arrest versus asphyxiation cardiac arrest in a porcine model

    Institute of Scientific and Technical Information of China (English)

    Wu Caijun; Li Chunsheng; Zhang Yi; Yang Jun

    2014-01-01

    Background The two most prevalent causes of sudden cardiac death are ventricular fibrillation cardiac arrest (VFCA) and asphyxiation cardiac arrest (ACA).Profound postresuscitation myocardial dysfunction has been demonstrated in both VFCA and ACA animal models.Our study aimed to characterize the two porcine models of cardiac arrest and postresuscitation myocardial metabolism dysfunction.Methods Thirty-two pigs were randomized into two groups.The VFCA group (n=16) were subject to programmed electrical stimulation and the ACA group (n=16) underwent endotracheal tube clamping to induce cardiac arrest (CA).Once induced,CA remained untreated for a period of 8 minutes.Two minutes following initiation of cardiopulmonary resuscitation (CPR),defibrillation was attempted until return of spontaneous circulation (ROSC) was achieved or animals died.To assess myocardial metabolism,18F-FluoroDeoxyGlucose Positron Emission Tomography was performed at baseline and 4 hours after ROSC.Results ROSC was 100% successful in VFCA and 50% successful in ACA.VFCA had better mean arterial pressure and cardiac output after ROSC than ACA.Arterial blood gas analysis indicated more detrimental metabolic disturbances in ACA compared with VFCA after ROSC (ROSC 0.5 hours,pH:7.01±0.06 vs.7.21±0.03,P<0.01; HCO3-:(15.83±2.31 vs.20.11±1.83) mmol/L,P<0.01; lactate:(16.22±1.76 vs.5.84±1.44) mmol/L,P<0.01).Myocardial metabolism imaging using Positron Emission Tomography demonstrated that myocardial injuries after ACA were more severe and widespread than after VFCA at 4 hours after ROSC (the maximum standardized uptake value of the whole left ventricular:1.00±0.17 vs.1.93±0.27,P<0.01).Lower contents of myocardial energy metabolism enzymes (Na+-K+-ATPase enzyme activity,Ca2+-ATPase enzyme activity,superoxide dismutase and phosphodiesterase) were found in ACA relative to VFCA.Conclusions Compared with VFCA,ACA causes more severe myocardium injury and metabolism hindrance,therefore they

  14. Impact of thoracic surgery on cardiac morphology and function in small animal models of heart disease: a cardiac MRI study in rats.

    Directory of Open Access Journals (Sweden)

    Peter Nordbeck

    Full Text Available BACKGROUND: Surgical procedures in small animal models of heart disease might evoke alterations in cardiac morphology and function. The aim of this study was to reveal and quantify such potential artificial early or long term effects in vivo, which might account for a significant bias in basic cardiovascular research, and, therefore, could potentially question the meaning of respective studies. METHODS: Female Wistar rats (n = 6 per group were matched for weight and assorted for sham left coronary artery ligation or control. Cardiac morphology and function was then investigated in vivo by cine magnetic resonance imaging at 7 Tesla 1 and 8 weeks after the surgical procedure. The time course of metabolic and inflammatory blood parameters was determined in addition. RESULTS: Compared to healthy controls, rats after sham surgery showed a lower body weight both 1 week (267.5±10.6 vs. 317.0±11.3 g, n<0.05 and 8 weeks (317.0±21.1 vs. 358.7±22.4 g, n<0.05 after the intervention. Left and right ventricular morphology and function were not different in absolute measures in both groups 1 week after surgery. However, there was a confined difference in several cardiac parameters normalized to the body weight (bw, such as myocardial mass (2.19±0.30/0.83±0.13 vs. 1.85±0.22/0.70±0.07 mg left/right per g bw, p<0.05, or enddiastolic ventricular volume (1.31±0.36/1.21±0.31 vs. 1.14±0.20/1.07±0.17 µl left/right per g bw, p<0.05. Vice versa, after 8 weeks, cardiac masses, volumes, and output showed a trend for lower values in sham operated rats compared to controls in absolute measures (782.2±57.2/260.2±33.2 vs. 805.9±84.8/310.4±48.5 mg, p<0.05 for left/right ventricular mass, but not normalized to body weight. Matching these findings, blood testing revealed only minor inflammatory but prolonged metabolic changes after surgery not related to cardiac disease. CONCLUSION: Cardio-thoracic surgical procedures in experimental myocardial infarction

  15. State-shared model for multiple-input multiple-output systems

    Institute of Scientific and Technical Information of China (English)

    Zhenhua TIAN; Karlene A. HOO

    2005-01-01

    This work proposes a method to construct a state-shared model for multiple-input multiple-output (MIMO)systems. A state-shared model is defined as a linear time invariant state-space structure that is driven by measurement signals-the plant outputs and the manipulated variables, but shared by different multiple input/output models. The genesis of the state-shared model is based on a particular reduced non-minimal realization. Any such realization necessarily fulfills the requirement that the output of the state-shared model is an asymptotically correct estimate of the output of the plant, if the process model is selected appropriately. The approach is demonstrated on a nonlinear MIMO system- a physiological model of calcium fluxes that controls muscle contraction and relaxation in human cardiac myocytes.

  16. 基于无偏灰色模糊马尔可夫链法的建筑业产值预测--以重庆为例%Output Value of Construction Industry Forecasting Based on Unbiased Grey-Fuzzy-Markov Chain Method by Taking ChongQing as an Example

    Institute of Scientific and Technical Information of China (English)

    刘贵文; 易志勇

    2014-01-01

    建筑业作为支柱产业,科学预测对其发展具有重要意义。单一评价模型因其各自局限性无法提高预测精确度,多种模型相结合评价较有优势,将无偏理论与模糊集合引入传统灰色马尔可夫预测模型,从拟合度和状态模糊集分类方面改进无偏灰色模糊马尔可夫模型。基于重庆1991~2011年建筑业产值,对其市场趋势进行预测分析,详细阐述该方法在建筑业产值预测中运用,定性分析预测结果,对建筑业发展历史及近期趋势进行检验和预判。%Construction industry is a pillar industry in China. Scientific prediction is of great significance to its development. Single evaluation model cannot improve the prediction accuracy because of its respective limitations. The evaluation through a variety of models combined together has an advantage,thus,the unbiased grey theory and fuzzy classification have been introduced into the traditional grey-Markov models. Unbiased grey-fuzzy Markov model is improved through the aspects of fitting degree and state classification of fuzzy set. Based on construction industry output value from 1991 to 2011 in Chongqing,this paper forecasts the market trend analysis,and elaborates the method used in the construction industry output value forecast. Through qualitative analysis of prediction results of the method,this paper gives a inspection and an anticipation about history and recent development of construction.

  17. UFO - The Universal FEYNRULES Output

    Science.gov (United States)

    Degrande, Céline; Duhr, Claude; Fuks, Benjamin; Grellscheid, David; Mattelaer, Olivier; Reiter, Thomas

    2012-06-01

    We present a new model format for automatized matrix-element generators, the so-called Universal FEYNRULES Output (UFO). The format is universal in the sense that it features compatibility with more than one single generator and is designed to be flexible, modular and agnostic of any assumption such as the number of particles or the color and Lorentz structures appearing in the interaction vertices. Unlike other model formats where text files need to be parsed, the information on the model is encoded into a PYTHON module that can easily be linked to other computer codes. We then describe an interface for the MATHEMATICA package FEYNRULES that allows for an automatic output of models in the UFO format.

  18. Cardiac tumors: echo assessment.

    Science.gov (United States)

    Mankad, Rekha; Herrmann, Joerg

    2016-12-01

    Cardiac tumors are exceedingly rare (0.001-0.03% in most autopsy series). They can be present anywhere within the heart and can be attached to any surface or be embedded in the myocardium or pericardial space. Signs and symptoms are nonspecific and highly variable related to the localization, size and composition of the cardiac mass. Echocardiography, typically performed for another indication, may be the first imaging modality alerting the clinician to the presence of a cardiac mass. Although echocardiography cannot give the histopathology, certain imaging features and adjunctive tools such as contrast imaging may aid in the differential diagnosis as do the adjunctive clinical data and the following principles: (1) thrombus or vegetations are the most likely etiology, (2) cardiac tumors are mostly secondary and (3) primary cardiac tumors are mostly benign. Although the finding of a cardiac mass on echocardiography may generate confusion, a stepwise approach may serve well practically. Herein, we will review such an approach and the role of echocardiography in the assessment of cardiac masses.

  19. Practical textbook of cardiac CT and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Tae-Hwan (ed.) [ASAN Medical Center, Seoul (Korea, Republic of). Dept. of Radiology

    2015-04-01

    Guide to the interpretation of cardiac CT and MRI for the purposes of diagnosis, treatment planning, and follow-up. Emphasis on applications in a wide range of real clinical situations. Numerous informative illustrations. Summarizing sections permitting rapid retrieval of information. QR codes allowing access to references, additional figures, and motion pictures from the internet. This up-to-date textbook comprehensively reviews all aspects of cardiac CT and MRI and demonstrates the value of these techniques in clinical practice. A wide range of applications are considered, including imaging of atherosclerotic and non-atherosclerotic coronary artery disease, coronary revascularization, ischemic heart disease, non-ischemic cardiomyopathy, valvular heart disease, cardiac tumors, and pericardial disease. The numerous high-quality images illustrate how to interpret cardiac CT and MRI correctly for the purposes of diagnosis, treatment planning, and follow-up. Helpful summarizing sections in every chapter will facilitate rapid retrieval of information. This book will be of great value to radiologists and cardiologists seeking a reliable guide to the optimal use of cardiac CT and MRI in real clinical situations.

  20. Airway Management of the Cardiac Surgical Patients: Current Perspective

    Science.gov (United States)

    Choudhury, Arindam; Gupta, Nishkarsh; Magoon, Rohan; Kapoor, Poonam Malhotra

    2017-01-01

    The difficult airway (DA) is a common problem encountered in patients undergoing cardiac surgery. However, the challenge is not only just establishment of airway but also maintaining a definitive airway for the safe conduct of cardiopulmonary bypass from initiation to weaning after surgical correction or palliation, de-airing of cardiac chambers. This review describes the management of the DA in a cardiac theater environment. The primary aims are recognition of DA both anatomical and physiological, necessary preparations for (and management of) difficult intubation and extubation. All patients undergoing cardiac surgery should initially be considered as having potentially DA as many of them have poor physiologic reserve. Making the cardiac surgical theater environment conducive to DA management is as essential as it is to deal with low cardiac output syndrome or acute heart failure. Tube obstruction and/or displacement should be suspected in case of a new onset ventilation problem, especially in the recovery unit. Cardiac anesthesiologists are often challenged with DA while inducing general endotracheal anesthesia. They ought to be familiar with the DA algorithms and possess skill for using the latest airway adjuncts. PMID:28074820

  1. Contribution of Agricultural Input to Output in Hohhot City

    Institute of Scientific and Technical Information of China (English)

    Tinghe; DENG; Jie; TIAN

    2013-01-01

    Based on the research data from the economics and management platform of Inner Mongolia Agricultural University,we analyze the changes in the input of agricultural production factors,such as farmland,labor and capital in Hohhot City. Based on the principle of econometrics,we select the agricultural production input-output data in Hohhot City during the period 1992-2010,and establish the econometric model using Cobb-Douglas production factor,to estimate the rate of contribution of agricultural input to the growth of agricultural output value,and study the quantitative relations between agricultural input and agricultural output value. The results show that in Hohhot City,the contribution of chemical fertilizer input to the growth of agricultural output value is the greatest; the contribution of mechanical power to agricultural output value is still not brought into full play; the contribution of remaining production inputs ( including technical progress) accounts for 35. 69% . In the future,Hohhot City should pay more attention to the technical input to develop agriculture.

  2. Cardiac function and myocardial perfusion immediately following maximal treadmill exercise inside the MRI room

    Directory of Open Access Journals (Sweden)

    Ballinger Michelle R

    2008-01-01

    Full Text Available Abstract Treadmill exercise stress testing is an essential tool in the prevention, detection, and treatment of a broad spectrum of cardiovascular disease. After maximal exercise, cardiac images at peak stress are typically acquired using nuclear scintigraphy or echocardiography, both of which have inherent limitations. Although CMR offers superior image quality, the lack of MRI-compatible exercise and monitoring equipment has prevented the realization of treadmill exercise CMR. It is critical to commence imaging as quickly as possible after exercise to capture exercise-induced cardiac wall motion abnormalities. We modified a commercial treadmill such that it could be safely positioned inside the MRI room to minimize the distance between the treadmill and the scan table. We optimized the treadmill exercise CMR protocol in 20 healthy volunteers and successfully imaged cardiac function and myocardial perfusion at peak stress, followed by viability imaging at rest. Imaging commenced an average of 30 seconds after maximal exercise. Real-time cine of seven slices with no breath-hold and no ECG-gating was completed within 45 seconds of exercise, immediately followed by stress perfusion imaging of three short-axis slices which showed an average time to peak enhancement within 57 seconds of exercise. We observed a 3.1-fold increase in cardiac output and a myocardial perfusion reserve index of 1.9, which agree with reported values for healthy subjects at peak stress. This study successfully demonstrates in-room treadmill exercise CMR in healthy volunteers, but confirmation of feasibility in patients with heart disease is still needed.

  3. Molecular Basis of Cardiac Myxomas

    Directory of Open Access Journals (Sweden)

    Pooja Singhal

    2014-01-01

    Full Text Available Cardiac tumors are rare, and of these, primary cardiac tumors are even rarer. Metastatic cardiac tumors are about 100 times more common than the primary tumors. About 90% of primary cardiac tumors are benign, and of these the most common are cardiac myxomas. Approximately 12% of primary cardiac tumors are completely asymptomatic while others present with one or more signs and symptoms of the classical triad of hemodynamic changes due to intracardiac obstruction, embolism and nonspecific constitutional symptoms. Echocardiography is highly sensitive and specific in detecting cardiac tumors. Other helpful investigations are chest X-rays, magnetic resonance imaging and computerized tomography scan. Surgical excision is the treatment of choice for primary cardiac tumors and is usually associated with a good prognosis. This review article will focus on the general features of benign cardiac tumors with an emphasis on cardiac myxomas and their molecular basis.

  4. Incremental value of a combination of cardiac troponin T, N-terminal pro-brain natriuretic peptide and C-reactive protein for prediction of mortality in end-stage renal disease

    DEFF Research Database (Denmark)

    Hallén, Jonas; Madsen, Lene Helleskov; Ladefoged, Søren

    2011-01-01

    Abstract Objective. To determine the relative prognostic merits of C-reactive protein (CRP), cardiac troponin T (cTnT) and N-terminal pro-brain natriuretic peptide (NT-pro-BNP) for prediction of all-cause death in patients with end-stage renal disease (ESRD) receiving haemodialysis. Material...... were predictive of death in univariate analysis. In multivariable analysis, elevated cTnT (> 0.01 µg/l) and CRP (> 1.0 mg/dl) remained significantly associated with mortality [hazard ratio (95% confidence interval), 3.2 (1.2-8.5), p = 0.017 for cTnT; 2.0 (1.0-3.8), p = 0.032 for CRP], while NT...

  5. Successful use of levosimendan as a primary inotrope in pediatric cardiac surgery: An observational study in 110 patients

    Directory of Open Access Journals (Sweden)

    Reena Khantwal Joshi

    2016-01-01

    Conclusions: Levosimendan-based inotropic regime offers optimized cardiac output with a well-controlled heart rate and a low incidence of arrhythmias in patients undergoing all categories of congenital heart surgeries.

  6. Prolonged hypoxia increases survival even in Zebrafish (Danio rerio showing cardiac arrhythmia.

    Directory of Open Access Journals (Sweden)

    Renate Kopp

    Full Text Available Tolerance towards hypoxia is highly pronounced in zebrafish. In this study even beneficial effects of hypoxia, specifically enhanced survival of zebrafish larvae, could be demonstrated. This effect was actually more pronounced in breakdance mutants, which phenotypically show cardiac arrhythmia. Breakdance mutants (bre are characterized by chronically reduced cardiac output. Despite an about 50% heart rate reduction, they become adults, but survival rate significantly drops to 40%. Normoxic bre animals demonstrate increased hypoxia inducible factor 1 a (Hif-1α expression, which indicates an activated hypoxic signaling pathway. Consequently, cardiovascular acclimation, like cardiac hypertrophy and increased erythrocyte concentration, occurs. Thus, it was hypothesized, that under hypoxic conditions survival might be even more reduced. When bre mutants were exposed to hypoxic conditions, they surprisingly showed higher survival rates than under normoxic conditions and even reached wildtype values. In hypoxic wildtype zebrafish, survival yet exceeded normoxic control values. To specify physiological acclimation, cardiovascular and metabolic parameters were measured before hypoxia started (3 dpf, when the first differences in survival rate occurred (7 dpf and when survival rate plateaued (15 dpf. Hypoxic animals expectedly demonstrated Hif-1α accumulation and consequently enhanced convective oxygen carrying capacity. Moreover, bre animals showed a significantly enhanced heart rate under hypoxic conditions, which reached normoxic wildtype values. This improvement in convective oxygen transport ensured a sufficient oxygen and nutrient supply and was also reflected in the significantly higher mitochondrial activity. The highly optimized energy metabolism observed in hypoxic zebrafish larvae might be decisive for periods of higher energy demand due to organ development, growth and increased activity. However, hypoxia increased survival only during a

  7. Prognostic value of myocardial perfusion single photon emission computed tomography for major adverse cardiac cerebrovascular and renal events in patients with chronic kidney disease: results from first year of follow-up of the Gunma-CKD SPECT multicenter study

    Energy Technology Data Exchange (ETDEWEB)

    Kasama, Shu [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Cardiovascular Hospital of Central Japan (Kitakanto Cardiovascular Hospital), Department of Cardiovascular Medicine, Gunma (Japan); Toyama, Takuji [Department of Cardiovascular Medicine, Gunma Prefectural Cardiovascular Center, Maebashi (Japan); Sato, Makito [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Tatebayashi Kosei Hospital, Department of Internal Medicine, Gunma (Japan); Sano, Hirokazu [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Isesaki Municipal Hospital, Department of Cardiovascular Medicine, Isesaki (Japan); Ueda, Tetsuya [Fujioka General Hospital, Division of Cardiology, Fujioka (Japan); Sasaki, Toyoshi [Takasaki General Medical Center, Division of Cardiology, Takasaki (Japan); Nakahara, Takehiro; Kurabayashi, Masahiko [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Higuchi, Tetsuya; Tsushima, Yoshito [Gunma University Graduate School of Medicine, Department of Diagnostic Radiology and Nuclear Medicine, Maebashi (Japan)

    2016-02-15

    Patients with chronic kidney disease (CKD) have an increased risk of adverse cardio-cerebrovascular events. We examined whether stress myocardial perfusion single photon emission computed tomography (SPECT) provides reliable prognostic markers for these patients. In this multicenter, prospective cohort trial from the Gunma-CKD SPECT study protocol, patients with CKD [estimated glomerular filtration rate (eGFR) < 60 min/ml per 1.73 m{sup 2}] undergoing stress {sup 99m}Tc-tetrofosmin SPECT for suspected or possible ischemic heart disease were initially followed for 1 year, with the following study endpoints: primary, the occurrence of cardiac deaths (CDs), and secondary, major adverse cardiac, cerebrovascular, and renal events (MACCREs). The summed stress score (SSS), summed rest score, and summed difference score (SDS) were estimated with the standard 17-segment, 5-point scoring model. Left ventricular end-diastolic volume, end-systolic volume (ESV), and ejection fraction were measured using electrocardiogram-gated SPECT. During the first year of follow-up, 69 of 299 patients experienced MACCREs (CD, n = 7; non-fatal myocardial infarction, n = 3; hospitalization for heart failure, n = 13; cerebrovascular accident, n = 1; need for revascularization, n = 38; and renal failure, i.e., hemodialysis initiation, n = 7). ESV and SSS were associated with CDs (p < 0.05), and eGFR and SDS were associated with MACCREs (p < 0.05), in multivariate logistic analysis. Patients with high ESV and high SSS had a significantly higher CD rate during the first year than the other CKD patient subgroups (p < 0.05). Patients with low eGFR and high SDS had a significantly higher MACCRE rate than the other subgroups (p < 0.05). Myocardial perfusion SPECT can provide reliable prognostic markers for patients with CKD. (orig.)

  8. Spike output jitter, mean firing time and coefficient of variation

    Science.gov (United States)

    Feng, Jianfeng; Brown, David

    1998-01-01

    To understand how a single neurone processes information, it is critical to examine the relationship between input and output. Marsalek, Koch and Maunsell's study focused on output jitter (standard deviation of output interpike interval) found that for the integrate-and-fire (I&F) model this response measure converges towards zero as the number of inputs increases indefinitely when interarrival times of excitatory inputs (EPSPs) are normally or uniformly distributed. In this work we present a complete, theoretical investigation, corroborated by numerical simulation, of output jitter in the I&F model with a variety of input distributions and a range of values of number of inputs, N. Our main results are: the exponential distribution input is a critical case and its output jitter is independent of N. For input distributions with tails which decrease faster than the exponential distribution, output jitter converges to zero as discovered by Marsalek, Koch and Maunsell; whereas an input distribution with a more slowly decreasing tail induces divergence of output jitter. Exact formulae for mean firing time are also obtained which enable us to estimate the coefficient of variation. The I&F model with leakage is also briefly considered.

  9. Cardiac Tumors; Tumeurs cardiaques

    Energy Technology Data Exchange (ETDEWEB)

    Laissy, J.P.; Fernandez, P. [Centre Hospitalier Universitaire Bichat Claude Bernard, Service d' Imagerie, 76 - Rouen (France); Mousseaux, E. [Hopital Europeen Georges Pompidou (HEGP), Service de Radiologie Cardio Vasculaire et Interventionnelle, 75 - Paris (France); Dacher, J.N. [Centre Hospitalier Universitaire Charles Nicolle, 75 - Rouen (France); Crochet, D. [Centre Hospitalier Universitaire, Hopital Laennec, Centre Hemodynamique, Radiologie Thoracique et Vasculaire, 44 - Nantes (France)

    2004-04-01

    Metastases are the most frequent tumors of the heart even though they seldom are recognized. Most primary cardiac tumors are benign. The main role of imaging is to differentiate a cardiac tumor from thrombus and rare pseudo-tumors: tuberculoma, hydatid cyst. Echocardiography is the fist line imaging technique to detect cardiac tumors, but CT and MRl arc useful for further characterization and differential diagnosis. Myxoma of the left atrium is the most frequent benign cardiac tumor. It usually is pedunculated and sometimes calcified. Sarcoma is the most frequent primary malignant tumor and usually presents as a sessile infiltrative tumor. Lymphoma and metastases are usually recognized by the presence of known tumor elsewhere of by characteristic direct contiguous involvement. Diagnosing primary and secondary pericardial tumors often is difficult. Imaging is valuable for diagnosis, characterization, pre-surgical evaluation and follow-up. (author)

  10. Socially differentiated cardiac rehabilitation

    DEFF Research Database (Denmark)

    Meillier, Lucette Kirsten; Nielsen, Kirsten Melgaard; Larsen, Finn Breinholt;

    2012-01-01

    to a standard rehabilitation programme (SRP). If patients were identified as socially vulnerable, they were offered an extended version of the rehabilitation programme (ERP). Excluded patients were offered home visits by a cardiac nurse. Concordance principles were used in the individualised programme elements......%. Patients were equally distributed to the SRP and the ERP. No inequality was found in attendance and adherence among referred patients. Conclusions: It seems possible to overcome unequal referral, attendance, and adherence in cardiac rehabilitation by organisation of systematic screening and social......Aim: The comprehensive cardiac rehabilitation (CR) programme after myocardial infarction (MI) improves quality of life and results in reduced cardiac mortality and recurrence of MI. Hospitals worldwide face problems with low participation rates in rehabilitation programmes. Inequality...

  11. Cardiac arrest - cardiopulmonary resuscitation

    Institute of Scientific and Technical Information of China (English)

    Basri Lenjani; Besnik Elshani; Nehat Baftiu; Kelmend Pallaska; Kadir Hyseni; Njazi Gashi; Nexhbedin Karemani; Ilaz Bunjaku; Taxhidin Zaimi; Arianit Jakupi

    2014-01-01

    Objective:To investigate application of cardiopulmonary resuscitation(CPR) measures within the golden minutes inEurope.Methods:The material was taken from theUniversityClinical Center ofKosovo -EmergencyCentre inPristina, during the two(2) year period(2010-2011).The collected date belong to the patients with cardiac arrest have been recorded in the patients' log book protocol at the emergency clinic.Results:During the2010 to2011 in the emergency center of theCUCK inPristina have been treated a total of269 patients with cardiac arrest, of whom159 or59.1% have been treated in2010, and110 patients or40.9% in2011.Of the269 patients treated in the emergency centre,93 or34.6% have exited lethally in the emergency centre, and176 or 65.4% have been transferred to other clinics.In the total number of patients with cardiac arrest, males have dominated with186 cases, or69.1%.The average age of patients included in the survey was56.7 year oldSD±16.0 years.Of the269 patients with cardiac arrest, defibrillation has been applied for93 or34.6% of patients.In the outpatient settings defibrillation has been applied for3 or3.2% of patients.Patients were defibrillated with application of one to four shocks. Of27 cases with who have survived cardiac arrest, none of them have suffered cardiac arrest at home,3 or11.1% of them have suffered cardiac arrest on the street, and24 or88.9% of them have suffered cardiac arrest in the hospital.5 out of27 patients survived have ended with neurological impairment.Cardiac arrest cases were present during all days of the week, but frequently most reported cases have been onMonday with32.0% of cases, and onFriday with24.5% of cases. Conclusions:All survivors from cardiac arrest have received appropriate medical assistance within10 min from attack, which implies that if cardiac arrest occurs near an institution health care(with an opportunity to provide the emergent health care) the rate of survival is higher.

  12. Cardiac imaging in adults

    Energy Technology Data Exchange (ETDEWEB)

    Jaffe, C.C.

    1987-01-01

    This book approaches adult cardiac disease from the correlative imaging perspective. It includes chest X-rays and angiographs, 2-dimensional echocardiograms with explanatory diagrams for clarity, plus details on digital radiology, nuclear medicine techniques, CT and MRI. It also covers the normal heart, valvular heart disease, myocardial disease, pericardial disease, bacterial endocarditis, aortic aneurysm, cardiac tumors, and congenital heart disease of the adult. It points out those aspects where one imaging technique has significant superiority.

  13. Port Access Cardiac Surgery.

    Science.gov (United States)

    Viganó, Mario; Minzioni, Gaetano; Spreafico, Patrizio; Rinaldi, Mauro; Pasquino, Stefano; Ceriana, Piero; Locatelli, Alessandro

    2000-10-01

    The port-access technique for cardiac surgery was recently developed at Stanford University in California as a less invasive method to perform some cardiac operations. The port-access system has been described in detail elsewhere. It is based on femoral arterial and venous access for cardiopulmonary bypass (CPB) and on the adoption of a specially designed triple-lumen catheter described originally by Peters, and subsequently modified and developed in the definitive configuration called the endoaortic clamp.

  14. Awareness in cardiac anesthesia.

    LENUS (Irish Health Repository)

    Serfontein, Leon

    2010-02-01

    Cardiac surgery represents a sub-group of patients at significantly increased risk of intraoperative awareness. Relatively few recent publications have targeted the topic of awareness in this group. The aim of this review is to identify areas of awareness research that may equally be extrapolated to cardiac anesthesia in the attempt to increase understanding of the nature and significance of this scenario and how to reduce it.

  15. Post cardiac injury syndrome

    DEFF Research Database (Denmark)

    Nielsen, S L; Nielsen, F E

    1991-01-01

    The post-pericardiotomy syndrome is a symptom complex which is similar in many respects to the post-myocardial infarction syndrome and these are summarized under the diagnosis of the Post Cardiac Injury Syndrome (PCIS). This condition, which is observed most frequently after open heart surgery, i...... on the coronary vessels, with cardiac tamponade and chronic pericardial exudate. In the lighter cases, PCIS may be treated with NSAID and, in the more severe cases, with systemic glucocorticoid which has a prompt effect....

  16. Autonomic cardiac innervation

    OpenAIRE

    Hasan, Wohaib

    2013-01-01

    Autonomic cardiac neurons have a common origin in the neural crest but undergo distinct developmental differentiation as they mature toward their adult phenotype. Progenitor cells respond to repulsive cues during migration, followed by differentiation cues from paracrine sources that promote neurochemistry and differentiation. When autonomic axons start to innervate cardiac tissue, neurotrophic factors from vascular tissue are essential for maintenance of neurons before they reach their targe...

  17. Infected cardiac hydatid cyst

    OpenAIRE

    Ceviz, M; Becit, N; Kocak, H.

    2001-01-01

    A 24 year old woman presented with chest pain and palpitation. The presence of a semisolid mass—an echinococcal cyst or tumour—in the left ventricular apex was diagnosed by echocardiography, computed tomography, and magnetic resonance imaging. The infected cyst was seen at surgery. The cyst was removed successfully by using cardiopulmonary bypass with cross clamp.


Keywords: cardiac hydatid cyst; infected cardiac hydatid cyst

  18. Judicial Influence on Policy Outputs?

    DEFF Research Database (Denmark)

    Martinsen, Dorte Sindbjerg

    2015-01-01

    to override unwanted jurisprudence. In this debate, the Court of Justice of the European Union (CJEU) has become famous for its central and occasionally controversial role in European integration. This article examines to what extent and under which conditions judicial decisions influence European Union (EU......) social policy outputs. A taxonomy of judicial influence is constructed, and expectations of institutional and political conditions on judicial influence are presented. The analysis draws on an extensive novel data set and examines judicial influence on EU social policies over time, that is, between 1958...

  19. Cardiac applications of optogenetics.

    Science.gov (United States)

    Ambrosi, Christina M; Klimas, Aleksandra; Yu, Jinzhu; Entcheva, Emilia

    2014-08-01

    In complex multicellular systems, such as the brain or the heart, the ability to selectively perturb and observe the response of individual components at the cellular level and with millisecond resolution in time, is essential for mechanistic understanding of function. Optogenetics uses genetic encoding of light sensitivity (by the expression of microbial opsins) to provide such capabilities for manipulation, recording, and control by light with cell specificity and high spatiotemporal resolution. As an optical approach, it is inherently scalable for remote and parallel interrogation of biological function at the tissue level; with implantable miniaturized devices, the technique is uniquely suitable for in vivo tracking of function, as illustrated by numerous applications in the brain. Its expansion into the cardiac area has been slow. Here, using examples from published research and original data, we focus on optogenetics applications to cardiac electrophysiology, specifically dealing with the ability to manipulate membrane voltage by light with implications for cardiac pacing, cardioversion, cell communication, and arrhythmia research, in general. We discuss gene and cell delivery methods of inscribing light sensitivity in cardiac tissue, functionality of the light-sensitive ion channels within different types of cardiac cells, utility in probing electrical coupling between different cell types, approaches and design solutions to all-optical electrophysiology by the combination of optogenetic sensors and actuators, and specific challenges in moving towards in vivo cardiac optogenetics.

  20. Fractal fluctuations in cardiac time series

    Science.gov (United States)

    West, B. J.; Zhang, R.; Sanders, A. W.; Miniyar, S.; Zuckerman, J. H.; Levine, B. D.; Blomqvist, C. G. (Principal Investigator)

    1999-01-01

    Human heart rate, controlled by complex feedback mechanisms, is a vital index of systematic circulation. However, it has been shown that beat-to-beat values of heart rate fluctuate continually over a wide range of time scales. Herein we use the relative dispersion, the ratio of the standard deviation to the mean, to show, by systematically aggregating the data, that the correlation in the beat-to-beat cardiac time series is a modulated inverse power law. This scaling property indicates the existence of long-time memory in the underlying cardiac control process and supports the conclusion that heart rate variability is a temporal fractal. We argue that the cardiac control system has allometric properties that enable it to respond to a dynamical environment through scaling.

  1. Patch in Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    Alireza Alizadeh Ghavidel

    2014-06-01

    Full Text Available Introduction: Excessive bleeding presents a risk for the patient in cardiovascular surgery. Local haemostatic agents are of great value to reduce bleeding and related complications. TachoSil (Nycomed, Linz, Austria is a sterile, haemostatic agent that consists of an equine collagen patchcoated with human fibrinogen and thrombin. This study evaluated the safety and efficacy of TachoSil compared to conventional technique.Methods: Forty-two patients scheduled for open heart surgeries, were entered to this study from August 2010 to May 2011. After primary haemostatic measures, patients divided in two groups based on surgeon’s judgment. Group A: 20 patients for whom TachoSil was applied and group B: 22 patients that conventional method using Surgicel (13 patients or wait and see method (9 cases, were performed in order to control the bleeding. In group A, 10 patients were male with mean age of 56.95±15.67 years and in group B, 9 cases were male with mean age of 49.95±14.41 years. In case group 70% (14/20 of the surgeries were redo surgeries versus 100% (22/22 in control group.Results: Baseline characteristics were similar in both groups. In TachoSil group 75% of patients required transfusion versus 90.90% in group B (P=0.03.Most transfusions consisted of packed red blood cell; 2±1.13 units in group A versus 3.11±1.44 in group B (P=0.01, however there were no significant differences between two groups regarding the mean total volume of intra and post-operative bleeding. Re-exploration was required in 10% in group A versus 13.63% in group B (P=0.67.Conclusion: TachoSil may act as a superior alternative in different types of cardiac surgery in order to control the bleeding and therefore reducing transfusion requirement.

  2. Integration of TMVA Output into Jupyter notebooks

    CERN Document Server

    Saliji, Albulena

    2016-01-01

    The purpose of this report is to describe the work that I have been doing during these past eight weeks as a Summer Student at CERN. The task which was assigned to me had to do with the integration of TMVA Output into Jupyter notebooks. In order to integrate the TMVA Output into the Jupyter notebook, first, improvement of the TMVA Output in the terminal was required. Once the output was improved, it needed to be transformed into HTML output and at the end it would be possible to integrate that output into the Jupyter notebook.

  3. Relationship between peak cardiac pumping capability and indices of cardio-respiratory fitness in healthy individuals.

    Science.gov (United States)

    Jakovljevic, Djordje G; Popadic-Gacesa, Jelena Z; Barak, Otto F; Nunan, David; Donovan, Gay; Trenell, Michael I; Grujic, Nikola G; Brodie, David A

    2012-09-01

    Cardiac power output (CPO) is a unique and direct measure of overall cardiac function (i.e. cardiac pumping capability) that integrates both flow- and pressure-generating capacities of the heart. The present study assessed the relationship between peak exercise CPO and selected indices of cardio-respiratory fitness. Thirty-seven healthy adults (23 men and 14 women) performed an incremental exercise test to volitional fatigue using the Bruce protocol with gas exchange and ventilatory measurements. Following a 40-min recovery, the subjects performed a constant maximum workload exercise test at or above 95% of maximal oxygen consumption. Cardiac output was measured using the exponential CO(2) rebreathing method. The CPO, expressed in W, was calculated as the product of the mean arterial blood pressure and cardiac output. At peak exercise, CPO was well correlated with cardiac output (r = 0·92, P<0·01), stroke volume (r = 0·90, P<0·01) and peak oxygen consumption (r = 0·77, P<0·01). The coefficient of correlation was moderate between CPO and anaerobic threshold (r = 0·47, P<0·01), oxygen pulse (r = 0·57, P<0·01), minute ventilation (r = 0·53, P<0·01) and carbon dioxide production (r = 0·56, P<0·01). Small but significant relationship was found between peak CPO and peak heart rate (r = 0·23, P<0·05). These findings suggest that only peak cardiac output and stroke volume truly reflect CPO. Other indices of cardio-respiratory fitness such as oxygen consumption, anaerobic threshold, oxygen pulse, minute ventilation, carbon dioxide production and heart rate should not be used as surrogates for overall cardiac function and pumping capability of the heart.

  4. [Psychosomatic aspects of cardiac arrhythmias].

    Science.gov (United States)

    Siepmann, Martin; Kirch, Wilhelm

    2010-07-01

    Emotional stress facilitates the occurrence of cardiac arrhythmias including sudden cardiac death. The prevalence of anxiety and depression is increased in cardiac patients as compared to the normal population. The risk of cardiovascular mortality is enhanced in patients suffering from depression. Comorbid anxiety disorders worsen the course of cardiac arrhythmias. Disturbance of neurocardiac regulation with predominance of the sympathetic tone is hypothesized to be causative for this. The emotional reaction to cardiac arrhythmias is differing to a large extent between individuals. Emotional stress may result from coping with treatment of cardiac arrhythmias. Emotional stress and cardiac arrhythmias may influence each other in the sense of a vicious circle. Somatoform cardiac arrhythmias are predominantly of psychogenic origin. Instrumental measures and frequent contacts between physicians and patients may facilitate disease chronification. The present review is dealing with the multifaceted relationships between cardiac arrhythmias and emotional stress. The underlying mechanisms and corresponding treatment modalities are discussed.

  5. Intensive insulin therapy in the intensive cardiac care unit.

    Science.gov (United States)

    Hasin, Tal; Eldor, Roy; Hammerman, Haim

    2006-01-01

    Treatment in the intensive cardiac care unit (ICCU) enables rigorous control of vital parameters such as heart rate, blood pressure, body temperature, oxygen saturation, serum electrolyte levels, urine output and many others. The importance of controlling the metabolic status of the acute cardiac patient and specifically the level of serum glucose was recently put in focus but is still underscored. This review aims to explain the rationale for providing intensive control of serum glucose levels in the ICCU, especially using intensive insulin therapy and summarizes the available clinical evidence suggesting its effectiveness.

  6. 经食管超声心动图用于累及右心的下腔静脉瘤栓切除术的临床价值%Clinical value of transesophageal echocardiography for surgical resection of inferior vena caval tumor thrombus with cardiac extension

    Institute of Scientific and Technical Information of China (English)

    陈唯韫; 朱斌; 刘兴荣; 张超纪; 马国涛; 苗齐; 黄宇光

    2014-01-01

    本院2010年3月至2013年12月在经食管超声心动图(TEE)术中监测下完成了6例累及右心的下腔静脉瘤栓切除术.6例患者术前检查均显示下腔静脉瘤栓延伸至右心.麻醉诱导后TEE发现,其中3例与术前检查结果有差别,故调整外科决策,决定不使用体外循环,在TEE密切监测下切开下腔静脉完整取出瘤栓.另3例患者TEE结果与术前类似,在体外循环下行瘤栓切除术.根据TEE结果,调整麻醉管理,特别是血流动力学管理方案,调整容量以及血管活性药的使用.手术切除后TEE检查均未见残余瘤栓,但是在3例右心严重受累患者均观察到重度三尖瓣返流.术后随访未见TEE使用相关并发症.本文总结报道了TEE在累及右心的下腔静脉瘤栓切除术中的应用,TEE提供的信息可纠正、优化外科决策和麻醉管理,评估手术效果,具有重要的临床应用价值.%Inferior vena caval (IVC) tumor thrombus with cardiac extension is a very rare phenomenon,which proliferates fast and could be very challenging to the surgery.This paper was designed to investigate the clinical value of transesophageal echocardiography (TEE) for the surgical resection of IVC tumor thrombus extending into right cardiac cavities.Six cases from our medical institute,preoperatively diagnosed as IVC tumor thrombus with cardiac extension and scheduled for the surgical resection,were retrospectively analyzed.In addition to real-time and dynamic monitoring,comprehensive TEE exams were performed for all the patients respectively after anesthesia induction,namely before tumor resection and after tumor resection.Cardiac extension was defined by the preoperative finding of cardiac mass originated from IVC tumor thrombus by transthoracic echocardiography,computerized tomography or CT angiography.In all the cases,intraoperative TEE provided an accurate and excellent view of the IVC tumor thrombus.For case three,the IVC tumor thrombus was found at the IVC

  7. The application value of spatiotemporal image correlation combined with tomographic ultrasound imaging in prenatal screening of common cardiac malposition%时间空间相关成像技术联合断层超声显像技术在产前筛查常见心脏位置异常中的应用价值

    Institute of Scientific and Technical Information of China (English)

    吴娟; 栗河舟; 丛娟; 刘云

    2012-01-01

    目的:探讨时间空间相关成像技术联合断层超声显像技术(TUI-STIC技术)在产前筛查常见心脏位置异常中的临床应用价值.方法:应用时间空间相关成像技术采集胎儿心脏的容积图像,再应用断层超声显像技术进行分析,要求清晰显示上腹部横切面及四腔心切面并标明左右方位.结果:199例心脏位置异常胎儿心脏容积数据经断层超声显像技术处理均获得满意的上腹部横切面及四腔心切面.其中右位心67例;左旋心5例;中位心7例;异位心2例;心脏移位107例;心脏异构11例.结论:判断胎儿心脏位置的主要切面是上腹部横切面和四腔心切面.时间空间相关成像技术联合断层超声显像技术简易、准确,可作为产前筛查胎儿心脏位置异常的有效方法.%Objective; To explore the clinical application value of spatiotemporal image correlation combined with tomographic ultrasound imaging (STIC -TUI technique) in prenatal screening of common cardiac malposition. Methods; STIC technique was used to collect fetal cardiac volume images, then TUI technique was used for analysis, the transverse section through the upper abdominal portion and four - chamber view were displayed clearly, and the positions were indicated. Results; Satisfactory transverse section through the upper abdominal portion and four - chamber view were obtained after analyzing the data of fetal cardiac volume of 199 cases with fetal cardiac malposition by TUI technique. Sixty -seven cases with dextrocardia, five cases with levoverted heart, seven cases with mesocardia, two cases with exocardia, one hundred and seven cases with displacement of heart, and eleven cases with heterogeneous heart were found. Conclusion; The main views to judge fetal cardiac position include transverse section through the upper abdominal portion and four - chamber view, STIC - TUI technique is simple and accurate, which can be used as an effective method for

  8. Judicial Influence on Policy Outputs?

    DEFF Research Database (Denmark)

    Martinsen, Dorte Sindbjerg

    2015-01-01

    The ability of courts to generate political change has long been debated in national, comparative, and international politics. In the examination of the interaction between judicial and legislative politics, scholars have disagreed on the degree of judicial power and the ability of politics...... to override unwanted jurisprudence. In this debate, the Court of Justice of the European Union (CJEU) has become famous for its central and occasionally controversial role in European integration. This article examines to what extent and under which conditions judicial decisions influence European Union (EU......) social policy outputs. A taxonomy of judicial influence is constructed, and expectations of institutional and political conditions on judicial influence are presented. The analysis draws on an extensive novel data set and examines judicial influence on EU social policies over time, that is, between 1958...

  9. Output regulation problem for discrete-time linear time-delay systems by output feedback control

    Institute of Scientific and Technical Information of China (English)

    Yamin YAN; Jie HUANG

    2016-01-01

    In this paper, we study the output regulation problem of discrete linear time-delay systems by output feedback control. We have established some results parallel to those for the output regulation problem of continuous linear time-delay systems.

  10. Cardiac radiology: centenary review.

    Science.gov (United States)

    de Roos, Albert; Higgins, Charles B

    2014-11-01

    During the past century, cardiac imaging technologies have revolutionized the diagnosis and treatment of acquired and congenital heart disease. Many important contributions to the field of cardiac imaging were initially reported in Radiology. The field developed from the early stages of cardiac imaging, including the use of coronary x-ray angiography and roentgen kymography, to nowadays the widely used echocardiographic, nuclear medicine, cardiac computed tomographic (CT), and magnetic resonance (MR) applications. It is surprising how many of these techniques were not recognized for their potential during their early inception. Some techniques were described in the literature but required many years to enter the clinical arena and presently continue to expand in terms of clinical application. The application of various CT and MR contrast agents for the diagnosis of myocardial ischemia is a case in point, as the utility of contrast agents continues to expand the noninvasive characterization of myocardium. The history of cardiac imaging has included a continuous process of advances in our understanding of the anatomy and physiology of the cardiovascular system, along with advances in imaging technology that continue to the present day.

  11. Discuss the Reasonableness of the Single Rate of Value Added Tax (VAT)--Based on the Analysis of the Input-Output Table%刍议增值税单一税率的可行性--基于投入产出表的分析

    Institute of Scientific and Technical Information of China (English)

    方轶旻; 陈锦; 林清清

    2014-01-01

    增值税是我国第一税种,其税率档次的合理性设置关乎国家财政及经济运行稳定。目前我国增值税税率档次设置过多,不利于税收征管以及税收公平。有部分学者提出实行增值税单一税率。本文应用投入产出法,在保持一定税负的条件下对各行业税负适用的税率进行测算,发现中间投入比率对于企业实际税负起到相当大的影响,各行业难以在单一税率的条件下,实现税负公平。为了优化整体税收环境,应当设置2至3档差别化税率,能够有效兼顾税收公平及效率。%Value added tax (VAT) is the ifrst tax in China;the set of its tax bracket decides the stability of national ifscal and economic running. Recently, the VAT tax bracket sets too much, which is not conducive to tax collection and tax justice. Some scholars have proposed to adopt the single rate of value added tax (VAT). In this article, we apply the Input-Output method. Under the condition of keeping taxes, we measure the Reasonable tax rate in various industries. To some extent, intermediate input ratio has a sizeable impact on the actual tax burden for enterprises. However, under the condition of single rate, industry cannot make fair tax burden. In order to optimize the overall tax environment, we shall set up 2 to 3 gear differential tax rate, which can effectively balance the tax fairness and efifciency.

  12. 彩超测定心脏瓣膜置换术前后左室壁应力的临床价值%Clinical value of color doppler ultrasound in detecting left ventricular wall stress pre-cardiac and post-cardiac valve replacement

    Institute of Scientific and Technical Information of China (English)

    雷文营; 孙秀英

    2001-01-01

    目的:探讨风湿性心脏瓣膜病换瓣术前后室壁应力的变化及其与左心室功能的关系。方法:应用Grossman左室壁应力公式计算收缩期最大径线左室壁应力(EdσM)、收缩末期径线左室壁应力(EsσM);应用M型图像测量和Teichholz方法计算左室收缩功能:左室短轴缩短率(FS)和左室射血分数(EF)。结果:置换术前后对照EdσM、EsσM、左室舒张末期容积(EDV)有不同程度减少和缩小;心功能不全时,EdσM、EsσM显著增加。结论:EdσM、EsσM指标可为临床术前适应证选择和术后恢复状况评价提供一定的参考价值。%Objective: To investigate the change of left ventricular wall stress and the relationship with left ventricular function pre- and post-cardiac valve replacement in patients with rheumatic valve heart disease.Methods:Left ventricular wall stress of systole maximam dimension (EdσM) and end-systole dimension (EsσM) was calculate by Grossman's formula of left ventricular stress and left ventricular systolic function (left ventricle minor axis shorten fraction and ejection fraction) was evaluated by M mode image measurement and Teichholz's method.Results: EdσM , EsσM and left ventricle end-diastolic volume (EDV) reduced in different degree pre-and post-replacement. EdσM, and EsσM increased distinctly when cardiac function was insufficient.Conclusion: The quota of EdσM and EsσM can offer reference for the choice of operation indications and evaluation of recovery effect after operation.

  13. Comprehensive cardiac rehabilitation

    DEFF Research Database (Denmark)

    Kruse, Marie; Hochstrasser, Stefan; Zwisler, Ann-Dorthe O;

    2006-01-01

    OBJECTIVES: The costs of comprehensive cardiac rehabilitation are established and compared to the corresponding costs of usual care. The effect on health-related quality of life is analyzed. METHODS: An unprecedented and very detailed cost assessment was carried out, as no guidelines existed...... for the situation at hand. Due to challenging circumstances, the cost assessment turned out to be ex-post and top-down. RESULTS: Cost per treatment sequence is estimated to be approximately euro 976, whereas the incremental cost (compared with usual care) is approximately euro 682. The cost estimate is uncertain...... and may be as high as euro 1.877. CONCLUSIONS: Comprehensive cardiac rehabilitation is more costly than usual care, and the higher costs are not outweighed by a quality of life gain. Comprehensive cardiac rehabilitation is, therefore, not cost-effective....

  14. Toothache of cardiac origin.

    Science.gov (United States)

    Kreiner, M; Okeson, J P

    1999-01-01

    Pain referred to the orofacial structures can sometimes be a diagnostic challenge for the clinician. In some instances, a patient may complain of tooth pain that is completely unrelated to any dental source. This poses a diagnostic and therapeutic problem for the dentist. Cardiac pain most commonly radiates to the left arm, shoulder, neck, and face. In rare instances, angina pectoris may present as dental pain. When this occurs, an improper diagnosis frequently leads to unnecessary dental treatment or, more significantly, a delay of proper treatment. This delay may result in the patient experiencing an acute myocardial infarction. It is the dentist's responsibility to establish a proper diagnosis so that the treatment will be directed toward the source of pain and not to the site of pain. This article reviews the literature concerning referred pain of cardiac origin and presents a case report of toothache of cardiac origin.

  15. Adding value(s)

    DEFF Research Database (Denmark)

    Carré, David

    2015-01-01

    , 1992). In response, behavioral economics (Camerer, 1999) has shown that agents have values other than optimization underpinning their decisions. Therefore, concerns arose regarding which values are guiding the agent but not about how such values became relevant for the agent. In this presentation, I......Most economic inquires revolve around agents making decisions. Getting the ‘best value’, it is assumed, drives such decisions: gaining most while risking least. This assumption has been debunked by showing that people does not always choose neither maximum benefit nor less risk (Kahneman & Tversky...... will explore the consequences of shifting to the latter perspective, i.e. looking for the generative framework of values. Here I argue that economic behavior should also be seen as a sense-making process, guided by values that are chosen/rejected along with fellow human beings, in specific socio...

  16. QT interval variability in body surface ECG : measurement, physiological basis, and clinical value: position statement and consensus guidance endorsed by the European Heart Rhythm Association jointly with the ESC Working Group on Cardiac Cellular Electrophysiology

    NARCIS (Netherlands)

    Baumert, Mathias; Porta, Alberto; Vos, Marc A; Malik, Marek; Couderc, Jean-Philippe; Laguna, Pablo; Piccirillo, Gianfranco; Smith, Godfrey L; Tereshchenko, Larisa G; Volders, Paul G A

    2016-01-01

    This consensus guideline discusses the electrocardiographic phenomenon of beat-to-beat QT interval variability (QTV) on surface electrocardiograms. The text covers measurement principles, physiological basis, and clinical value of QTV. Technical considerations include QT interval measurement and the

  17. The cardiac anxiety questionnaire: cross-validation among cardiac inpatients

    NARCIS (Netherlands)

    Beek, M.H. van; Oude Voshaar, R.C.; Deelen, F.M. van; Balkom, A.J. van; Pop, G.A.; Speckens, A.E.

    2012-01-01

    OBJECTIVE: General anxiety symptoms are common in patients with cardiac disease and considered to have an adverse effect on cardiac prognosis. The role of specific cardiac anxiety, however, is still unknown. The aim of this study is to examine the factor structure, reliability, and validity of the D

  18. THE CARDIAC ANXIETY QUESTIONNAIRE : CROSS-VALIDATION AMONG CARDIAC INPATIENTS

    NARCIS (Netherlands)

    van Beek, M. H. C. T.; Voshaar, R. C. Oude; van Deelen, F. M.; van Balkom, A. J. L. M.; Pop, G.; Speckens, A. E. M.

    2012-01-01

    Objective: General anxiety symptoms are common in patients with cardiac disease and considered to have an adverse effect on cardiac prognosis. The role of specific cardiac anxiety, however, is still unknown. The aim of this study is to examine the factor structure, reliability, and validity of the D

  19. Preventing Inductive Output Impedance of High-Frequency Emitter Follower Stages

    Directory of Open Access Journals (Sweden)

    R. C. Tozer

    1997-04-01

    Full Text Available Large output inductance is one of major issues of high-frequency emitter follower design. The most often suggested technique to reduce its value is the decreasing of AC transconductance which offers small output inductance at the expense of loosing low output resistance. The paper presents a different approach; it is shown that output inductance can be completely cancelled while keeping very low output resistance by introducing a pole at the input node which may be more suitable in many types of design. Complete analytical evaluation based on the full hybrid-n model of the bipolar transistor device is given.

  20. Perioperative management of cardiac disease.

    Science.gov (United States)

    Aresti, N A; Malik, A A; Ihsan, K M; Aftab, S M E; Khan, W S

    2014-01-01

    Pre-existing cardiac disease contributes significantly to morbidity and mortality amongst patients undergoing non cardiac surgery. Patients with pre-existing cardiac disease or with risk factors for it, have as much as a 3.9% risk of suffering a major perioperative cardiac event (Lee et al 1999, Devereaux 2005). Furthermore, the incidence of perioperative myocardial infarction (MI) is increased 10 to 50 fold in patients with previous coronary events (Jassal 2008).

  1. Reduced pallidal output causes dystonia

    Directory of Open Access Journals (Sweden)

    Atsushi eNambu

    2011-11-01

    Full Text Available Dystonia is a neurological disorder characterized by sustained or repetitive involuntary muscle contractions and abnormal postures. In the present article, we will introduce our recent electrophysiological studies in hyperkinetic transgenic mice generated as a model of DYT1 dystonia and in a human cervical dystonia patient, and discuss the pathophysiology of dystonia on the basis of these electrophysiological findings. Recording of neuronal activity in the awake state of DYT1 dystonia model mice revealed reduced spontaneous activity with bursts and pauses in both internal (GPi and external (GPe segments of the globus pallidus. Electrical stimulation of the primary motor cortex evoked responses composed of excitation and subsequent long-lasting inhibition, the latter of which was never observed in normal mice. In addition, somatotopic arrangements were disorganized in the GPi and GPe of dystonia model mice. In a human cervical dystonia patient, electrical stimulation of the primary motor cortex evoked similar long-lasting inhibition in the GPi and GPe. Thus, reduced GPi output may cause increased thalamic and cortical activity, resulting in the involuntary movements observed in dystonia.

  2. Model output: fact or artefact?

    Science.gov (United States)

    Melsen, Lieke

    2015-04-01

    As a third-year PhD-student, I relatively recently entered the wonderful world of scientific Hydrology. A science that has many pillars that directly impact society, for example with the prediction of hydrological extremes (both floods and drought), climate change, applications in agriculture, nature conservation, drinking water supply, etcetera. Despite its demonstrable societal relevance, hydrology is often seen as a science between two stools. Like Klemeš (1986) stated: "By their academic background, hydrologists are foresters, geographers, electrical engineers, geologists, system analysts, physicists, mathematicians, botanists, and most often civil engineers." Sometimes it seems that the engineering genes are still present in current hydrological sciences, and this results in pragmatic rather than scientific approaches for some of the current problems and challenges we have in hydrology. Here, I refer to the uncertainty in hydrological modelling that is often neglected. For over thirty years, uncertainty in hydrological models has been extensively discussed and studied. But it is not difficult to find peer-reviewed articles in which it is implicitly assumed that model simulations represent the truth rather than a conceptualization of reality. For instance in trend studies, where data is extrapolated 100 years ahead. Of course one can use different forcing datasets to estimate the uncertainty of the input data, but how to prevent that the output is not a model artefact, caused by the model structure? Or how about impact studies, e.g. of a dam impacting river flow. Measurements are often available for the period after dam construction, so models are used to simulate river flow before dam construction. Both are compared in order to qualify the effect of the dam. But on what basis can we tell that the model tells us the truth? Model validation is common nowadays, but validation only (comparing observations with model output) is not sufficient to assume that a

  3. The Value of Value

    DEFF Research Database (Denmark)

    Sørensen, Asger

    and the regularity of such a phenomenon is both hard to verify and, if true, difficult to explain, it seems fair to say that since the Enlightenment, an approaching fin-de-siecle has brought an increased interest in matters concerning morality and ethics.1 The present peak has in public-political discourse and some...... parts of business ethics given prominence to especially one term, namely `value'. The question that interests me is the following: What does the articulation of ethics and morality in terms of values mean for ethics and morality as such. Or, to put the question in a more fashionably way: What...... is the value of value for morality and ethics?To make things a bit more precise, we can make use of the common distinction between ethics and morality, i.e. that morality is the immediate, collective and unconscious employment of morals, whereas ethics is the systematic, individual and conscious reflections...

  4. Data analysis in cardiac arrhythmias.

    Science.gov (United States)

    Rodrigo, Miguel; Pedrón-Torecilla, Jorge; Hernández, Ismael; Liberos, Alejandro; Climent, Andreu M; Guillem, María S

    2015-01-01

    Cardiac arrhythmias are an increasingly present in developed countries and represent a major health and economic burden. The occurrence of cardiac arrhythmias is closely linked to the electrical function of the heart. Consequently, the analysis of the electrical signal generated by the heart tissue, either recorded invasively or noninvasively, provides valuable information for the study of cardiac arrhythmias. In this chapter, novel cardiac signal analysis techniques that allow the study and diagnosis of cardiac arrhythmias are described, with emphasis on cardiac mapping which allows for spatiotemporal analysis of cardiac signals.Cardiac mapping can serve as a diagnostic tool by recording cardiac signals either in close contact to the heart tissue or noninvasively from the body surface, and allows the identification of cardiac sites responsible of the development or maintenance of arrhythmias. Cardiac mapping can also be used for research in cardiac arrhythmias in order to understand their mechanisms. For this purpose, both synthetic signals generated by computer simulations and animal experimental models allow for more controlled physiological conditions and complete access to the organ.

  5. Biosynthesis of cardiac natriuretic peptides

    DEFF Research Database (Denmark)

    Goetze, Jens Peter

    2010-01-01

    Cardiac-derived peptide hormones were identified more than 25 years ago. An astonishing amount of clinical studies have established cardiac natriuretic peptides and their molecular precursors as useful markers of heart disease. In contrast to the clinical applications, the biogenesis of cardiac...

  6. Cardiac and vascular changes in cirrhosis: Pathogenic mechanisms

    Institute of Scientific and Technical Information of China (English)

    HongQun Liu; Seyed Ali Gaskari; Samuel S Lee

    2006-01-01

    Cardiovascular abnormalities accompany both portal hypertension and cirrhosis. These consist of hyperdynamic circulation, defined as reduced mean arterial pressure and systemic vascular resistance, and increased cardiac output. Despite the baseline increased cardiac output,ventricular inotropic and chronotropic responses to stimuli are blunted, a condition known as cirrhotic cardiomyopathy. Both conditions may play an initiating or aggravating pathogenic role in many of the complications of liver failure or portal hypertension including ascites,variceal bleeding, hepatorenal syndrome and increased postoperative mortality after major surgery or liver transplantation. This review briefly examines the major mechanisms that may underlie these cardiovascular abnormalities, concentrating on nitric oxide, endogenous cannabinoids, central neural activation and adrenergic receptor changes. Future work should address the complex interrelationships between these systems.

  7. Cardiac safety in vascular access surgery and maintenance.

    Science.gov (United States)

    Malik, Jan; Kudlicka, Jaroslav; Tesar, Vladimir; Linhart, Ales

    2015-01-01

    More than 50% of all end-stage renal disease (ESRD) patients die from cardiovascular complications. Among them, heart failure and pulmonary hypertension play a major role, and published studies document significantly higher mortality rates in patients with these two states. Arteriovenous fistulas (AVF) and arteriovenous grafts (AVG) are the preferred types of vascular access (VA). However, both AVF and AVG increase cardiac output and in turn could contribute to (the decompensation of) heart failure or pulmonary hypertension. No really safe access flow volume exists, and the ESRD patients' reactions to it vary considerably. We review the mechanisms involved in the cardiovascular consequences of increased cardiac output and available literary data. The link between access flow volume and increased mortality due to pulmonary hypertension or heart failure probably exists, but still has not been directly evidenced. Regular echocardiography is advisable especially in patients with symptoms or with high VA flow (>1,500 ml/min).

  8. Cardiac troponins and high-sensitivity cardiac troponin assays.

    Science.gov (United States)

    Conrad, Michael J; Jarolim, Petr

    2014-03-01

    Measurement of circulating cardiac troponins I and T has become integral to the diagnosis of myocardial infarction. This article discusses the structure and function of the troponin complex and the release of cardiac troponin molecules from the injured cardiomyocyte into the circulation. An overview of current cardiac troponin assays and their classification according to sensitivity is presented. The diagnostic criteria, role, and usefulness of cardiac troponin for myocardial infarction are discussed. In addition, several examples are given of the usefulness of high-sensitivity cardiac troponin assays for short-term and long-term prediction of adverse events.

  9. THE PARTICIPATION MODE AND POSITION IN GLOBAL VALUE CHAINS OF CHINA AND JAPAN S MANUFACTURING INDUSTRY---Based on World Input-output Tables%中日制造业参与全球价值链分工模式及地位分析*--基于世界投入产出表

    Institute of Scientific and Technical Information of China (English)

    尹伟华

    2016-01-01

    本文基于世界投入产出表数据,通过构建后向和前向垂直专业化率及全球价值链地位指数,较全面地分析了中日两国制造业参与全球价值链的程度、模式和地位变化情况。结果表明:(1)中国制造业出口中国内增加值占比低于同期日本,其获益能力相对较低。(2)中日两国制造业后向和前向垂直专业化率均呈上升趋势,其参与全球价值链程度不断加深。(3)中国制造业参与全球价值链主要是以后向模式,而日本制造业主要是以前向模式。(4)中国制造业中国外增加值以最终产品为主,主要从事加工组装生产环节,而日本制造业中国外增加值以中间产品为主,专业化于关键零部件生产环节。(5)中日两国制造业主要是通过间接增加值出口实现全球价值链前向参与,且其国内的生产分工程度均在不断加深。(6)中国制造业位于全球价值链下游位置,且有一定的攀升趋势,而日本制造业位于全球价值链上游位置,但有一定的下滑趋势。%According to the ratios of vertical specialization including backward-linkage (VS)and for-ward-linkage (VS1)and global value chains (GVC)index,this paper analyzes the participation mode and position in GVC of China and Japan�s manufacturing industry using 1995—2011 world input-output tables (WIOTs)Our studies indicate the following:(1)Domestic value-added (DVA)share in China�s exports is lower than Japan�s It means that China�s profit ability is relatively low (2)VS and VS1 present an upward trend from 1995—2011 It means that the participation levels in GVC are rising for China and Japan�s man-ufacturing industry (3 )The participation modes of China�s manufacturing industry in GVC are mainly backward,while the participation modes of Japan�s manufacturing industry in GVC are mainly forward (4) China�s manufacturing industry which is dominated by foreign value-added (FVA

  10. Design of output voltage waveform on magnetic encoder

    Energy Technology Data Exchange (ETDEWEB)

    Shi Yu E-mail: shiyu_aaa@163.com; Zhang Huaiwu; Jiang Xiangdong; Wen Qiye; Han Baoshan

    2004-11-01

    A novel design model based on slant multi-phase filter (SMPF) theory is presented. By the theory nth harmonic voltage (n=2nd, 3rd and 4th...(V)) can be reduced easily. Magnetic encoder with sinusoidal output voltage waveform has been developed and sinusoidal output waveform can be easily improved. The minimum of distortion factor was observed when the difference of slant phase is 2{pi}3. This result agrees with SMPF theory value {phi}=4.904 deg. (p=0.8 mm, l=3 mm, {delta}{theta}=2{pi}3]. This result can be widely used in magnetoresistive sensor fields.

  11. Spatial repolarization heterogeneity detected by magnetocardiography correlates with cardiac iron overload and adverse cardiac events in beta-thalassemia major.

    Directory of Open Access Journals (Sweden)

    Chun-An Chen

    Full Text Available BACKGROUND: Patients with transfusion-dependent beta-thalassemia major (TM are at risk for myocardial iron overload and cardiac complications. Spatial repolarization heterogeneity is known to be elevated in patients with certain cardiac diseases, but little is known in TM patients. The purpose of this study was to evaluate spatial repolarization heterogeneity in patients with TM, and to investigate the relationships between spatial repolarization heterogeneity, cardiac iron load, and adverse cardiac events. METHODS AND RESULTS: Fifty patients with TM and 55 control subjects received 64-channel magnetocardiography (MCG to determine spatial repolarization heterogeneity, which was evaluated by a smoothness index of QTc (SI-QTc, a standard deviation of QTc (SD-QTc, and a QTc dispersion. Left ventricular function and myocardial T2* values were assessed by cardiac magnetic resonance. Patients with TM had significantly greater SI-QTc, SD-QTc, and QTc dispersion compared to the control subjects (all p values<0.001. Spatial repolarization heterogeneity was even more pronounced in patients with significant iron overload (T2*<20 ms, n = 20 compared to those with normal T2* (all p values<0.001. Loge cardiac T2* correlated with SI-QTc (r = -0.609, p<0.001, SD-QTc (r = -0.572, p<0.001, and QTc dispersion (r = -0.622, p<0.001, while all these indices had no relationship with measurements of the left ventricular geometry or function. At the time of study, 10 patients had either heart failure or arrhythmia. All 3 indices of repolarization heterogeneity were related to the presence of adverse cardiac events, with areas under the receiver operating characteristic curves (ranged between 0.79 and 0.86, similar to that of cardiac T2*. CONCLUSIONS: Multichannel MCG demonstrated that patients with TM had increased spatial repolarization heterogeneity, which is related to myocardial iron load and adverse cardiac events.

  12. Cardiac potassium channel subtypes

    DEFF Research Database (Denmark)

    Schmitt, Nicole; Grunnet, Morten; Olesen, Søren-Peter

    2014-01-01

    About 10 distinct potassium channels in the heart are involved in shaping the action potential. Some of the K(+) channels are primarily responsible for early repolarization, whereas others drive late repolarization and still others are open throughout the cardiac cycle. Three main K(+) channels...

  13. Cardiac Risk Assessment

    Science.gov (United States)

    ... Risk Assessment Related tests: Lipid Profile , VLDL Cholesterol , hs-CRP , Lp(a) Overview | Common Questions | Related Pages What ... cardiac risk include: High-sensitivity C-reactive protein (hs-CRP) : Studies have shown that measuring CRP with a ...

  14. The cardiac malpositions.

    Science.gov (United States)

    Perloff, Joseph K

    2011-11-01

    Dextrocardia was known in the 17th century and was 1 of the first congenital malformations of the heart to be recognized. Fifty years elapsed before Matthew Baillie published his account of complete transposition in a human of the thoracic and abdominal viscera to the opposite side from what is natural. In 1858, Thomas Peacock stated that "the heart may be congenitally misplaced in various ways, occupying either an unusual position within the thorax, or being situated external to that cavity." In 1915, Maude Abbott described ectopia cordis, and Richard Paltauf's remarkable illustrations distinguished the various types of dextrocardia. In 1928, the first useful classification of the cardiac malpositions was proposed, and in 1966, Elliott et al's radiologic classification set the stage for clinical recognition. The first section of this review deals with the 3 basic cardiac malpositions in the presence of bilateral asymmetry. The second section deals with cardiac malpositions in the presence of bilateral left-sidedness or right-sidedness. Previous publications on cardiac malpositions are replete with an arcane vocabulary that confounds rather than clarifies. Even if the terms themselves are understood, inherent complexity weighs against clarity. This review was designed as a guided tour of an unfamiliar subject.

  15. Hepato-cardiac disorders

    Institute of Scientific and Technical Information of China (English)

    Yasser; Mahrous; Fouad; Reem; Yehia

    2014-01-01

    Understanding the mutual relationship between the liver and the heart is important for both hepatologists and cardiologists. Hepato-cardiac diseases can be classified into heart diseases affecting the liver, liver diseases affecting the heart, and conditions affecting the heart and the liver at the same time. Differential diagnoses of liver injury are extremely important in a cardiologist’s clinical practice calling for collaboration between cardiologists and hepatologists due to the many other diseases that can affect the liver and mimic haemodynamic injury. Acute and chronic heart failure may lead to acute ischemic hepatitis or chronic congestive hepatopathy. Treatment in these cases should be directed to the primary heart disease. In patients with advanced liver disease, cirrhotic cardiomyopathy may develop including hemodynamic changes, diastolic and systolic dysfunctions, reduced cardiac performance and electrophysiological abnormalities. Cardiac evaluation is important for patients with liver diseases especially before and after liver transplantation. Liver transplantation may lead to the improvement of all cardiac changes and the reversal of cirrhotic cardiomyopathy. There are systemic diseases that may affect both the liver and the heart concomitantly including congenital, metabolic and inflammatory diseases as well as alcoholism. This review highlights these hepatocardiac diseases

  16. Transesophageal Doppler reliably tracks changes in cardiac output in comparison with intermittent pulmonary artery thermodilution in cardiac surgery patients

    DEFF Research Database (Denmark)

    Møller-Sørensen, Hasse; Cordtz, Johan Joakim; Østergaard, Morten;

    2016-01-01

    completed the study. Each patient were placed in the following successive positions: (1) supine, (2) head-down tilt, (3) head-up tilt, (4) supine, (5) supine with phenylephrine administration, (6) pace heart rate 80 beats per minute (bpm), (7) pace heart rate 110 bpm. The agreement of compared data...

  17. Relationship between Multi-Output Partially Bent Functions and Multi-Output Bent Functions

    Institute of Scientific and Technical Information of China (English)

    ZHAO Yaqun; JU Guizhi; WANG Jue

    2006-01-01

    In this paper, the definition of multi-output partially Bent functions is presented and some properties are discussed. Then the relationship between multi-output partially Bent functions and multi-output Bent functions is given in Theorem 4, which includes Walsh spectrum expression and function expression. This shows that multi-output partially Bent functions and multi-output Bent functions can define each other in principle. So we obtain the general method to construct multi-output partially Bent functions from multi-output Bent functions.

  18. The left ventricle as a mechanical engine: from Leonardo da Vinci to the echocardiographic assessment of peak power output-to-left ventricular mass.

    Science.gov (United States)

    Dini, Frank L; Guarini, Giacinta; Ballo, Piercarlo; Carluccio, Erberto; Maiello, Maria; Capozza, Paola; Innelli, Pasquale; Rosa, Gian M; Palmiero, Pasquale; Galderisi, Maurizio; Razzolini, Renato; Nodari, Savina

    2013-03-01

    The interpretation of the heart as a mechanical engine dates back to the teachings of Leonardo da Vinci, who was the first to apply the laws of mechanics to the function of the heart. Similar to any mechanical engine, whose performance is proportional to the power generated with respect to weight, the left ventricle can be viewed as a power generator whose performance can be related to left ventricular mass. Stress echocardiography may provide valuable information on the relationship between cardiac performance and recruited left ventricular mass that may be used in distinguishing between adaptive and maladaptive left ventricular remodeling. Peak power output-to-mass, obtained during exercise or pharmacological stress echocardiography, is a measure that reflects the number of watts that are developed by 100 g of left ventricular mass under maximal stimulation. Power output-to-mass may be calculated as left ventricular power output per 100 g of left ventricular mass: 100× left ventricular power output divided by left ventricular mass (W/100 g). A simplified formula to calculate power output-to-mass is as follows: 0.222 × cardiac output (l/min) × mean blood pressure (mmHg)/left ventricular mass (g). When the integrity of myocardial structure is compromised, a mismatch becomes apparent between maximal cardiac power output and left ventricular mass; when this occurs, a reduction of the peak power output-to-mass index is observed.

  19. Impact of intra-aortic balloon counterpulsation with different balloon volumes on cardiac performance in humans.

    Science.gov (United States)

    Cohen, Marc; Fasseas, Panayotis; Singh, Varinder P; McBride, Ruth; Orford, James L; Kussmaul, William G

    2002-10-01

    Intra-aortic balloon (IAB) counterpulsation can augment the cardiac output. However, the effect of different IAB volumes on cardiac performance has not been adequately evaluated in humans. Eighty-two patients (52 males [63%]; mean age, 65 +/- 12 years; mean body surface area [BSA], 1.8 +/- 0.2 m(2)) had IAB counterpulsation for cardiogenic shock, refractory angina, and preoperatively for high-risk cardiac surgery. Cardiac hemodynamics were prospectively studied during IAB with inflation volumes of 32 vs. 40 cc. Hemodynamic data collected included aortic pressure, pulmonary artery pressure, systemic and mixed venous oxygen saturations, and cardiac output (by Fick). Transthoracic echocardiography (TTE) was used to obtain both velocity time integrals (VTIs) and the area of the left ventricular outflow tract (LVOT). Left ventricular stroke volume was then calculated as LVOT area x VTI. Cardiac output (CO) determined by the Fick method and VTI did not differ significantly (P = NS) between the two inflation volumes (y = 0.002 + 0.97x). In a subgroup of 33 patients with BSA

  20. Effects of dopamine infusion on cardiac and renal blood flows in dogs.

    Science.gov (United States)

    Furukawa, Shuji; Nagashima, Yukiko; Hoshi, Katsuichiro; Hirao, Hidehiro; Tanaka, Ryou; Maruo, Kohji; Yamane, Yoshihisa

    2002-01-01

    In veterinary medicine, dopamine is currently being administered clinically by infusion for treatment of kidney disorders at low doses (high doses (> or = 5 microg/kg/min). However, since high doses of dopamine cause peripheral vasoconstriction due to its effect on alpha adrenoceptors, high doses have no longer been recommended. The present study was conducted to explore possible regimens for the use of dopamine infusion in dogs. The regional (renal and cardiac) blood flow for 60 min was measured by using colored microspheres at three doses (3, 10 and 20 microg/kg/min) of dopamine infusion in healthy anesthetized mongrel dogs. The effects on kidney and peripheral hemodynamics at each dose and the resultant cardiac output, mean arterial blood pressure and total peripheral resistance were determined. Renal blood flow increased markedly at 3 microg/kg/min dopamine. Improvement in hemodynamics indicated by marked increase in cardiac blood flow, cardiac output and mean arterial blood pressure and decreased total peripheral resistance was observed at higher doses (10 and 20 microg/kg/min). At 10 microg/kg/min, in addition to the satisfactory increase in cardiac blood flow, there was also a stable satisfactory increase in renal blood flow. However, at 20 microg/kg/min, increased myocardial oxygen consumption (manifested by marked increased in cardiac output), arrythmia and irregular increase in renal blood flow were detected. This study suggests that the clinical use of dopamine infusion in dogs could be safely expanded to moderately higher doses.

  1. Determination of output factors for stereotactic radiosurgery beams

    Energy Technology Data Exchange (ETDEWEB)

    Fan, J.; Paskalev, K.; Wang, L.; Jin, L.; Li, J.; Eldeeb, A.; Ma, C. [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111 (United States)

    2009-11-15

    Accurate dosimetry of the narrow beam tends to be difficult to perform due to the absence of lateral electronic equilibrium and the steep dose gradient, as well as the finite size of detectors. Thus, although the high dose rate 6 MV beam on the VARIAN Trilogy accelerator is increasingly utilized for stereotactic radiosurgery (SRS) treatment, there is no general agreement in the SRS beam output factor values among the Trilogy user community. Trilogy SRS beams are confined by cone collimators and the available collimator sizes range from 5 and 10 to 30 mm, in every 2 mm increment. A range of the relative output factors are in clinic use. This variation may impair observations of dose response and optimizations of the prescribed dose. It is necessary to investigate an accurate, easily performable, and detector independent method for the narrow beam output factor measurement. In this study, a scanning beam/scanning chamber method was proposed to overcome the limitation/difficulty of using a relatively large detector in narrow beam output factor measurement. Specifically, for the scanning beam method, multiple narrow beams are used for the dose measurement using a finite size chamber. These multiple scanning beams form an equivalent large uniform field which provides lateral electron equilibrium condition. After the measurement, the contributions from neighboring beams are deconvolved and the value is used for output factor determinations. For a Linac that cannot move a beam laterally, the scanning chamber method can be used to achieve the same result. The output factors determined in such a method were compared to chambers (a 0.015 cc PTW PinPoint ion chamber and a 0.125 cc PTW ion chamber) and film measurement, as well as with Monte Carlo simulation. Film and Monte Carlo results are found to be in excellent agreement with the measurement using the scan beam method. However, the VARIAN recommended output factors measured directly by Wellhoefer CC01 chamber and

  2. Exceptional cardiac anoxia tolerance in tilapia (Oreochromis hybrid).

    Science.gov (United States)

    Lague, Sabine L; Speers-Roesch, Ben; Richards, Jeffrey G; Farrell, Anthony P

    2012-04-15

    Anoxic survival requires the matching of cardiac ATP supply (i.e. maximum glycolytic potential, MGP) and demand (i.e. cardiac power output, PO). We examined the idea that the previously observed in vivo downregulation of cardiac function during exposure to severe hypoxia in tilapia (Oreochromis hybrid) represents a physiological strategy to reduce routine PO to within the heart's MGP. The MGP of the ectothermic vertebrate heart has previously been suggested to be ∼70 nmol ATP s(-1) g(-1), sustaining a PO of ∼0.7 mW g(-1) at 15°C. We developed an in situ perfused heart preparation for tilapia (Oreochromis hybrid) and characterized the routine and maximum cardiac performance under both normoxic (>20 kPa O(2)) and severely hypoxic perfusion conditions (tilapia heart maintained a routine normoxic cardiac output (Q) and PO under all hypoxic conditions, a result that contrasts with the hypoxic cardiac downregulation previously observed in vivo under less severe conditions. Thus, we conclude that the in vivo downregulation of routine cardiac performance in hypoxia is not needed in tilapia to balance cardiac energy supply and demand. Indeed, the MGP of the tilapia heart proved to be quite exceptional. Measurements of myocardial lactate efflux during severe hypoxia were used to calculate the MGP of the tilapia heart. The MGP was estimated to be 172 nmol ATP s(-1) g(-1) at 22°C, and allowed the heart to generate a PO(max) of at least ∼3.1 mW g(-1), which is only 30% lower than the PO(max) observed with normoxia. Even with this MGP, the additional challenge of acidosis during severe hypoxia decreased maximum ATP turnover rate and PO(max) by 30% compared with severe hypoxia alone, suggesting that there are probably direct effects of acidosis on cardiac contractility. We conclude that the high maximum glycolytic ATP turnover rate and levels of PO, which exceed those measured in other ectothermic vertebrate hearts, probably convey a previously unreported anoxia tolerance

  3. Effects of Obesity on Cardiovascular Hemodynamics, Cardiac Morphology, and Ventricular Function.

    Science.gov (United States)

    Alpert, Martin A; Omran, Jad; Bostick, Brian P

    2016-12-01

    Obesity produces a variety of hemodynamic alterations that may cause changes in cardiac morphology which predispose to left and right ventricular dysfunction. Various neurohormonal and metabolic alterations commonly associated with obesity may contribute to these abnormalities of cardiac structure and function. These changes in cardiovascular hemodynamics, cardiac morphology, and ventricular function may, in severely obese patients, predispose to heart failure, even in the absence of other forms of heart disease (obesity cardiomyopathy). In normotensive obese patients, cardiac involvement is commonly characterized by elevated cardiac output, low peripheral vascular resistance, and increased left ventricular (LV) end-diastolic pressure. Sleep-disordered breathing may lead to pulmonary arterial hypertension and, in association with left heart failure, may contribute to elevation of right heart pressures. These alterations, in association with various neurohormonal and metabolic abnormalities, may produce LV hypertrophy; impaired LV diastolic function; and less commonly, LV systolic dysfunction. Many of these alterations are reversible with substantial voluntary weight loss.

  4. Therapeutic application of inhaled nitric oxide in adult cardiac surgical patients.

    Science.gov (United States)

    Makker, Robina; Mehta, Yatin; Trehan, Naresh; Bapna, Rk

    2006-01-01

    Increased pulmonary vascular resistance can be detrimental to the cardiac output in post-operative cardiac surgical patients. Pulmonary vasodilator therapy by systemic pharmacologic agents is non-selective. Inhaled nitric oxide is a selective pulmonary vasodilator and does not cause systemic hypotension. In this prospective study, 14 adult post-operative cardiac surgical patients with pulmonary hypertension underwent inhaled nitric oxide therapy and their hemodynamic changes were evaluated. Inhaled nitric oxide was administered in doses of 5 ppm-25 ppm. The result was a decrease in pulmonary vascular resistance from 456.57 +/- 137.13 to 357.64 +/- 119.80 dynes-sec- Continued. - See Free Full Text.

  5. Value of Cardiac Structural and Functional Changes in Evaluation of Growth and Development of Children with Congenital Heart Disease%先天性心脏病患儿心脏结构和功能改变对生长发育评估价值的研究进展

    Institute of Scientific and Technical Information of China (English)

    郎圆圆(综述); 李沿江(审校)

    2014-01-01

    The factors for assessing the growth and development of children include height, weight,bone age,endocrine hormones,etc.Growth hormone (GH)is closely related to child growth and development.GH deficiency can damage cardiac structure and function.The growth and development of children with congenital heart disease(CHD)obviously lag behind normal children.Pulmonary hypertension and GH/IGF axis dysfunction have been confirmed as the risk factors.In this review,we summarize the mechanisms of growth retardation caused by CHD and the value of cardiac structural and functional changes in the evaluation of the growth and develop-ment of children.%评估儿童生长发育的因素有身高、体质量、骨龄、内分泌激素等,生长激素(growth hormone,GH)不仅与儿童生长发育关系密切,当其缺乏时亦会对心脏结构和功能造成损害。先天性心脏病(congenital heart disease, CHD)患儿生长发育明显落后于正常儿童,肺动脉高压、GH-IGF 轴功能紊乱是目前已得到证实的危险因素。本综述从 CHD 的发生、发展阐述其引起生长发育落后的相关机制及心脏结构和功能改变对儿童生长发育的评估意义。

  6. Sinopec H1 Oil Output Climbs Slightly

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    Sinopec Corp., China's largest oil refiner, announced in late-July that its crude oil output rose 4.33 percent to 163 million barrels year-on-year in the first half. Domestic crude oil output was up 1. 16 percent to 152 million barrels during the period, while overseas output jtmlped 82.46 percent to 11,13 million barrels, according to an unaudited repo,t released by tile company.

  7. The Global NR Output Kept Rising

    Institute of Scientific and Technical Information of China (English)

    Bo Wen

    2011-01-01

    In early November, Association of Natural Rubber Producing Countries in- dicated that from 2005 to 2011, the pro- ducing area and output of the global NR both kept rising. As predicted, the pro- ducing area will be 72 million hectares, the output will be 10.02 million tons and the average output will be 1,392 kg/hectare by the end of2011.

  8. 血浆大内皮素1对心脏再同步治疗反应性的预测价值%Predictive value of big endothelin-1 to responsiveness to cardiac resynchronization therapy

    Institute of Scientific and Technical Information of China (English)

    杨新玮; 华伟; 王靖; 丁立刚; 刘志敏; 李崇强; 陈柯萍; 张澍

    2013-01-01

    Objective To assess the predictive potency of big endothelin-1 (big ET-1) to response to cardiac resynchronization therapy (CRT).Methods We retrospectively analyzed the data of patients who underwent CRT-P/D implantation from Jan 2009 to Dec 2011.Big ET-1 and NT-proBNP were tested by ELISA kit at baseline.NYHA functional class,echocardiography were evaluated both at baseline and follow-up.Simpson method was applied to measure left ventricular ejection fraction (LVEF).Improvement of LVEF by 0.05 and reduction in NYHA class ≥ 1 grade was defined as responder.Improvement of LVEF by twice or the absolute level ≥ 0.50 with NYHA class Ⅰ or Ⅱ grade was defined as super-responder.Results Overall 93 patients aged (60.8 ± 11.0) years old included in this observational study.During 12 ~ 50 (27 ± 11.0) months follow-up,there were 34 non-responders,24 responders and 35 super-responders.Level of plasma big ET-1 in three groups were (1.2±0.9) pmol/L、(0.8±0.4) pmol/L and (0.8±0.6) pmol/L(P =0.003),respectively.Correlation between big ET-1 and NT-proBNP and between big ET-1 and response to CRT was r =0.469 (P =0.001) and r =-0.237(P=0.022),respectively.Conclusion Plasma big ET-1 correlated with the severity of heart failure.It could serve as a response predictor to CRT.High level of big ET-1 indicated non-responder.%目的 评价血浆大内皮素l(big ET-1)预测心脏再同步治疗(CRT)反应性的临床价值.方法 本研究回顾性分析了2009年1月至2011年12月间在阜外心血管病医院植入心脏再同步治疗起搏器和/或心脏再同步治疗除颤器(CRT-P/D)的患者.酶联免疫吸附试验(ELISA)测定基线big ET-1及氨基末端B型脑钠肽前体(NT-proBNP)水平,采集基线及随访期心功能(NYHA分级)和超声心动图指标,用Simpson法测定左心室射血分数(LVEF).心功能降低Ⅰ级同时LVEF提高≥0.05定义为有反应;LVEF提高2倍或绝对值≥0.50同时心功能改善至Ⅰ或

  9. Clinical significance of lactate in acute cardiac patients

    Institute of Scientific and Technical Information of China (English)

    Chiara; Lazzeri; Serafina; Valente; Marco; Chiostri; Gian; Franco; Gensini

    2015-01-01

    Lactate, as a metabolite of easy and quick assessment, has been studied over time in critically ill patients in order to evaluate its prognostic ability. The present review is focused on the prognostic role of lactate levels in acute cardiac patients(that is with acute coronary syndrome, cardiogenic shock, cardiac arrest, non including post cardiac surgery patients). In patients with STelevation myocardial infarction treated with mechanical revascularization, hyperlactatemia identified a subset of patients at higher risk for early death and in-hospital complications, being strictly related mainly to hemodynamic derangement. The prognostic impact of hyperlactatemia on mortality has been documented in patients with cardiogenic shock and in those with cardiac arrest even if there is no cut-off value of lactate to be associated with worse outcome or to guide resuscitation or hemodynamic management. Therapeutic hypothermia seems to affect per se lactate values which have been shown to progressively decrease during hypothermia. The mechanism(s) accounting for lactate levels during hypothemia seem to be multiple ranging from the metabolic effects of reduced temperatures to the hemodynamic effects of hypothermia(i.e., reduced need of vasopressor agents). Serial lactate measurements over time, or lactate clearance, have been reported to be clinically more reliable than lactate absolute value also in acute cardiac patients. Despite differences in study design, timing of lactate measurements and type of acute cardiac conditions(i.e., cardiogenic shock, cardiac arrest, refractory cardiac arrest), available evidence strongly suggests that higher lactate levels can be observed on admission in non-survivors and that higher lactate clearance is associated with better outcome.

  10. Clinical prognostic value of cardiac biochemical markers combined determination in mortality of patients with AECOPD%心脏生化标志物测定对AECOPD死亡率的预测价值

    Institute of Scientific and Technical Information of China (English)

    刘威威; 胡波; 殷青; 陈晓香

    2014-01-01

    Objective To evaluate the prognostic value of Troponin I and NT-proBNP for the recent prog-nosis in patients with AECOPD. Methods 210 patients with AECOPD were given arterial blood gas analysis, CURB65 scores, detection of C-reaction protein, body mass index, NT-proBNP and Troponin I. All patients were fol-lowed-up to compare the differences of each value between groups and evaluate the relationship between each value and prognosis in patients with AECOPD. Results The levels of PaCO2 , CURB65, Troponin I and NT-proBNP were obviously correlated with the death of AECOPD patient (all P<0. 05), which was reflected by Logistic multivariate analysis. NT-proBNP and troponin I levels appeared to have additive associations with mortality. Mortality among pa-tients with abnormalities of both NT-proBNP and troponin I was obviously higher than among patients with normal val-ues (P<0. 001). NT-proBNP and troponin I levels were positively correlated (P<0. 01). Conclusion NT-proB-NP and troponin I are strong predictors of early mortality among patients with AECOPD independent to other prognos-tic indicators. The joint detection has a better predictive value.%目的:研究升高的肌钙蛋白I和N-末端脑钠肽前体( NT-proBNP)水平对慢性阻塞性肺疾病急性加重期( AECOPD)患者近期预后的预测价值。方法210名AECOPD患者入院时进行动脉血气、社区获得性肺炎评分( CURB65评分)、C反应蛋白、体重指数、NT-proBNP及肌钙蛋白I测定,所有患者随访临床结局(存活和死亡),比较不同预后患者之间各指标的差异,评价这些指标与AECOPD预后的关系。结果 Logistic多因素分析显示,CURB65评分、血二氧化碳分压( PaCO2)、NT-proBNP和肌钙蛋白I水平与死亡率明显相关( P<0.05)。 NT-proBNP和肌钙蛋白I与死亡率有叠加关系:两者均升高组较正常组死亡率明显升高( P<0.001),NT-proBNP与肌钙蛋白I呈正相关( P<0.01)。结论肌钙蛋白I和NT-proBNP可作为

  11. Cardiac nuclear medicine

    Energy Technology Data Exchange (ETDEWEB)

    Gerson, M.C.

    1987-01-01

    The book begins with a review of the radionuclide methods available for evaluating cardiac perfusion and function. The authors discuss planar and tomographic thallium myocardial imaging, first-pass and equilibrium radionuclide angiography, and imaging with infarct-avid tracers. Several common but more specialized procedures are then reviewed: nonogemetric measurement of left ventricular volume, phase (Fourier) analysis, stroke volume ratio, right ventricular function, and diastolic function. A separate chapter is devoted to drug interventions and in particular the use of radionuclide ventriculography to monitor doxorubicin toxicity and therapy of congestive heart failure. The subsequent chapters provide a comprehensive guide to test selection, accuracy, and results in acute myocardial infarction, in postmyocardial infarction, in chronic coronary artery disease, before and after medical or surgical revascularization, in valvular heart disease, in cardiomyopathies, and in cardiac trauma.

  12. Sudden Cardiac Death

    Directory of Open Access Journals (Sweden)

    Yipsy María Gutiérrez Báez

    2015-09-01

    Full Text Available Since the second half of the twentieth century, dying suddenly due to heart-related problems has become the main health issue in all countries where infectious diseases are not prevalent. Sudden death from cardiac causes is an important global health problem. Major databases were searched for the leading causes of sudden cardiac death. It has been demonstrated that there is a group of hereditary diseases with structural alterations or without apparent organic cause that explains many cases of sudden death in young people, whether related or not to physical exertion. Certain population groups are at higher risk for this disease. They are relatively easy to identify and can be the target of primary prevention measures.

  13. Cardiac arrhythmias in pregnancy.

    Science.gov (United States)

    Knotts, Robert J; Garan, Hasan

    2014-08-01

    As more women with repaired congenital heart disease survive to their reproductive years and many other women are delaying pregnancy until later in life, a rising concern is the risk of cardiac arrhythmias during pregnancy. Naturally occurring cardiovascular changes during pregnancy increase the likelihood that a recurrence of a previously experienced cardiac arrhythmia or a de novo arrhythmia will occur. Arrhythmias should be thoroughly investigated to determine if there is a reversible etiology, and risks/benefits of treatment options should be fully explored. We discuss the approach to working up and treating various arrhythmias during pregnancy with attention to fetal and maternal risks as well as treatment of fetal arrhythmias. Acute management in stable patients includes close monitoring and intravenous pharmacologic therapy, while DC cardioversion should be used to terminate arrhythmias in hemodynamically unstable patients. Long-term management may require continued oral antiarrhythmic therapy, with particular attention to fetal safety, to prevent complications associated with arrhythmias.

  14. Cardiac muscarinic receptor overexpression in sudden infant death syndrome.

    Directory of Open Access Journals (Sweden)

    Angelo Livolsi

    Full Text Available BACKGROUND: Sudden infant death syndrome (SIDS remains the leading cause of death among infants less than 1 year of age. Disturbed expression of some neurotransmitters and their receptors has been shown in the central nervous system of SIDS victims but no biological abnormality of the peripheral vago-cardiac system has been demonstrated to date. The present study aimed to seek vago-cardiac abnormalities in SIDS victims. The cardiac level of expression of muscarinic receptors, as well as acetylcholinesterase enzyme activity were investigated. METHODOLOGY/PRINCIPAL FINDINGS: Left ventricular samples and blood samples were obtained from autopsies of SIDS and children deceased from non cardiac causes. Binding experiments performed with [(3H]NMS, a selective muscarinic ligand, in cardiac membrane preparations showed that the density of cardiac muscarinic receptors was increased as shown by a more than doubled B(max value in SIDS (n = 9 SIDS versus 8 controls. On average, the erythrocyte acetylcholinesterase enzyme activity was also significantly increased (n = 9 SIDS versus 11 controls. CONCLUSIONS: In the present study, it has been shown for the first time that cardiac muscarinic receptor overexpression is associated with SIDS. The increase of acetylcholinesterase enzyme activity appears as a possible regulatory mechanism.

  15. Hyperglycemia at admission and during hospital stay are independent risk factors for mortality in high risk cardiac patients admitted to an intensive cardiac care unit

    NARCIS (Netherlands)

    J.A. Lipton (Jonathan); R. Barendse (Rj); R.T. van Domburg (Ron); A.F.L. Schinkel (Arend); H. Boersma (Eric); M.L. Simoons (Maarten); K.M. Akkerhuis (Martijn)

    2013-01-01

    textabstractAims: Hyperglycemia is associated with increased mortality in cardiac patients. However, the predictive value of admission- and average glucose levels in patients admitted to an intensive cardiac care unit (ICCU) has not been described. Methods: Observational study of patients admitted t

  16. Cardiac surgery 2015 reviewed.

    Science.gov (United States)

    Doenst, Torsten; Strüning, Constanze; Moschovas, Alexandros; Gonzalez-Lopez, David; Essa, Yasin; Kirov, Hristo; Diab, Mahmoud; Faerber, Gloria

    2016-10-01

    For the year 2015, almost 19,000 published references can be found in PubMed when entering the search term "cardiac surgery". The last year has been again characterized by lively discussions in the fields where classic cardiac surgery and modern interventional techniques overlap. Lacking evidence in the field of coronary revascularization with either percutaneous coronary intervention or bypass surgery has been added. As in the years before, CABG remains the gold standard for the revascularization of complex stable triple-vessel disease. Plenty of new information has been presented comparing the conventional to transcatheter aortic valve implantation (TAVI) demonstrating similar short- and mid-term outcomes at high and low risk, but even a survival advantage with transfemoral TAVI at intermediate risk. In addition, there were many relevant and interesting other contributions from the purely operative arena. This review article will summarize the most pertinent publications in the fields of coronary revascularization, surgical treatment of valve disease, heart failure (i.e., transplantation and ventricular assist devices), and aortic surgery. While the article does not have the expectation of being complete and cannot be free of individual interpretation, it provides a condensed summary that is intended to give the reader "solid ground" for up-to-date decision-making in cardiac surgery.

  17. Cardiac tissue engineering

    Directory of Open Access Journals (Sweden)

    MILICA RADISIC

    2005-03-01

    Full Text Available We hypothesized that clinically sized (1-5 mm thick,compact cardiac constructs containing physiologically high density of viable cells (~108 cells/cm3 can be engineered in vitro by using biomimetic culture systems capable of providing oxygen transport and electrical stimulation, designed to mimic those in native heart. This hypothesis was tested by culturing rat heart cells on polymer scaffolds, either with perfusion of culture medium (physiologic interstitial velocity, supplementation of perfluorocarbons, or with electrical stimulation (continuous application of biphasic pulses, 2 ms, 5 V, 1 Hz. Tissue constructs cultured without perfusion or electrical stimulation served as controls. Medium perfusion and addition of perfluorocarbons resulted in compact, thick constructs containing physiologic density of viable, electromechanically coupled cells, in contrast to control constructs which had only a ~100 mm thick peripheral region with functionally connected cells. Electrical stimulation of cultured constructs resulted in markedly improved contractile properties, increased amounts of cardiac proteins, and remarkably well developed ultrastructure (similar to that of native heart as compared to non-stimulated controls. We discuss here the state of the art of cardiac tissue engineering, in light of the biomimetic approach that reproduces in vitro some of the conditions present during normal tissue development.

  18. Changes in absolute and relative importance in the prognostic value of left ventricular systolic function and congestive heart failure after acute myocardial infarction. TRACE Study Group. Trandolapril Cardiac Evaluation

    DEFF Research Database (Denmark)

    Køber, L; Torp-Pedersen, C; Jørgensen, S;

    1998-01-01

    ) by echocardiography, was assessed in 6,676 consecutive patients with an enzyme-confirmed AMI. So that changes in the prognostic value of WMI or CHF could be studied, separate analyses were performed at selected time periods. Average monthly mortality (deaths per 100 patients per month) was determined from life......Changes in the importance of left ventricular (LV) systolic dysfunction and congestive heart failure (CHF) with time after an acute myocardial infarction (AMI) after the introduction of thrombolytic therapy have not been studied. LV systolic function, measured as wall motion index (WMI...... dysfunction or CHF, monthly mortality was high during the first month (18.3 +/- 1.6% and 20.2 +/- 1.6%, respectively), decreased during the first year, and was stable thereafter (0.8 +/- 0.1% and 1.0 +/- 0.1%, respectively, average monthly mortality after year 3). The relative risk of LV dysfunction decreased...

  19. Input/output plugin architecture for MDSplus

    Energy Technology Data Exchange (ETDEWEB)

    Stillerman, Joshua, E-mail: jas@psfc.mit.edu [Massachusetts Institute of Technology, 175 Albany Street, Cambridge, MA 02139 (United States); Fredian, Thomas, E-mail: twf@psfc.mit.edu [Massachusetts Institute of Technology, 175 Albany Street, Cambridge, MA 02139 (United States); Manduchi, Gabriele, E-mail: gabriele.manduchi@igi.cnr.it [Consorzio RFX, Euratom-ENEA Association, Corso Stati Uniti 4, Padova 35127 (Italy)

    2014-05-15

    The first version of MDSplus was released in 1991 for VAX/VMS. Since that time the underlying file formats have remained constant. The software however has evolved, it was ported to unix, linux, Windows, and Macintosh. In 1997 a TCP based protocol, mdsip, was added to provide network access to MDSplus data. In 2011 a mechanism was added to allow protocol plugins to permit the use of other transport mechanisms such as ssh to access data users. This paper describes a similar design which permits the insertion of plugins to handle the reading and writing of MDSplus data at the data storage level. Tree paths become URIs which specify the protocol, host, and protocol specific information. The protocol is provided by a dynamically activated shared library that can provide any consistent subset of the data store access API, treeshr. The existing low level network protocol called mdsip, is activated by defining tree paths like “host::/directory”. Using the new plugin mechanism this is re-implemented as an instance of the general plugin that replaces the low level treeshr input/output routines. It is specified by using a path like “mdsip://host/directory”. This architecture will make it possible to adapt the MDSplus data organization and analysis tools to other underlying data storage. The first new application of this, after the existing network protocol is implemented, will be a plugin based on a key value store. Key value stores, can provide inexpensive scalable, redundant data storage. An example of this might be an Amazon G3 plugin which would let you specify a tree path such as “AG3://container” to access MDSplus data stored in the cloud.

  20. Activation of mitochondrial STAT-3 and reduced mitochondria damage during hypothermia treatment for post-cardiac arrest myocardial dysfunction.

    Science.gov (United States)

    Huang, Chien-Hua; Tsai, Min-Shan; Chiang, Chih-Yen; Su, Yu-Jen; Wang, Tzung-Dau; Chang, Wei-Tien; Chen, Huei-Wen; Chen, Wen-Jone

    2015-11-01

    While therapeutic hypothermia improves the outcomes of individuals in cardiac arrest, the hemodynamic responses and mechanisms which underlie hypothermia-induced cardioprotection are not fully understood. Therefore, we investigated the mechanism by which induced hypothermia preserves cardiac function and protects against mitochondrial damage following cardiac arrest. Cardiac arrest was induced in adult male Wistar rats by asphyxiation for 8.5 min. Following resuscitation, the animals were randomly assigned to a hypothermia (32 °C) or normothermia (37 °C) group. Monitoring results showed that cardiac output at the fourth hour after resuscitation was significantly better in rats treated with hypothermia when compared to rats treated with normothermia (P mitochondrial permeability transition pores occurred less frequently in the hypothermic group. While complex I/III activity in the electron transport reaction was damaged after cardiac arrest and resuscitation, the degree of injury was ameliorated by hypothermia treatment (P mitochondrial integrity and electron transport activity.

  1. [Berberine inhibits cardiac fibrosis of diabetic rats].

    Science.gov (United States)

    Lu, Kun; Shen, Yongjie; He, Jinfeng; Liu, Guoling; Song, Wei

    2016-10-01

    Objective To explore the effect of berberine on cardiac fibrosis of diabetic rats by observing the expressions of serum transforming growth factor-β1 (TGF-β1), connective tissue growth factor (CTGF) , collagen type 1 (Col1) and collagen type 3 (Col3) in myocardial tissues of diabetic rats after berberine treatment. Methods The diabetic model was induced by intraperitoneal injection of streptococci (STZ). Forty-three diabetic rats were randomly divided into diabetic model group (n=9), berberine treated groups of different doses [50, 100, 150 mg/(kg.d), gavage administration for 12 weeks; n=9, 9, 8 respectively], and metformin group as positive control (n=8); other 8 normal rats served as a negative control group. After the last administration, fasting blood glucose, left ventricular systolic pressure (LVSP) and left ventricular end diastolic pressure (LVEDP) were measured; rats' heart were taken to calculate the heart mass index (HMI); ELISA was used to detect the serum levels of TGF-β1 and CTGF; collagenous fibers in cardiac tissues were tested by Masson staining; collagen volume fraction (CVF) was measured by image analysis; Col1 and Col3 in cardiac tissues were determined by Western blotting. Results Compared with the normal control group, the fasting blood glucose, LVSP, LVEDP absolute value, HMI, the degree of cardiac fibrosis, the expressions of TGF-β1, CTGF, Col1 and Col3 significantly increased in the model group. All indexes mentioned above were reduced obviously in berberine treated groups of 100 and 150 mg/(kg.d). Conclusion Berberine improves cardiac fibrosis in diabetic rats through down-regulating the expressions of TGF-β1 and CTGF and reducing the synthesis and deposition of Col1 and Col3.

  2. Cardiac arrhythmias induced by chloral hydrate in rhesus monkeys.

    Science.gov (United States)

    Han, Pengfei; Song, Haibo; Yang, Pingliang; Xie, Huiqi; Kang, Y James

    2011-06-01

    Chloral hydrate has been long used as a safe sedative and hypnotic drug in humans. However, reports on its cardiovascular adverse effects have been published from time to time. The present study was undertaken to use Rhesus monkeys as a model to define the dose regiment of chloral hydrate at which cardiac arrhythmias can be induced and the consequences of the cardiac events. Male Rhesus monkeys of 2-3 years old were intravenously infused with chloral hydrate starting at 50 mg/kg with an increasing increment of 25 mg/kg until the occurrence of cardiac arrhythmias. In addition, a traditional up-and-down dosing procedure was applied to define a single dose level at which cardiac arrhythmias can be induced. The data obtained showed that when the sequentially escaladed dose reached 125 mg/kg, cardiac arrhythmias occurred in all monkeys tested. The single effective dose to cause cardiac arrhythmias calculated from the crossover analysis was 143 ± 4 mg/kg. This value would be equivalent to 68.6 ± 1.9 mg/kg for children and 46.4 ± 1.3 mg/kg for adults in humans. Under either multiple or single dose condition, cardiac arrhythmias did not occur before 40 min after the onset of anesthesia induced by chloral hydrate. Cardiac arrhythmias were recovered without help at the end of the anesthesia in most cases, but also continued after the regain of consciousness in some cases. The cardiac arrhythmias were accompanied with compromised cardiac function including suppressed fractional shortening and ejection fraction. This study thus suggests that cautions need to be taken when chloral hydrate is used above certain levels and beyond a certain period of anesthesia, and cardiac arrhythmias induced by chloral hydrate need to be closely monitored because compromised cardiac function may occur simultaneously. In addition, patients with cardiac arrhythmias induced by chloral hydrate should be monitored even after they are recovered from the anesthesia.

  3. THE NONSTATIONARITY OF GERMAN AGGREGATE OUTPUT

    NARCIS (Netherlands)

    ZELHORST, D; DEHAAN, J

    1993-01-01

    In this paper the stationarity of German per capita output for the period 1870-1989 is examined, using both a parametric and a non-parametric approach. The standard unit root tests and the scaled variogram suggest that German output is not stationary. Following the approach suggested by Perron (1989

  4. Practice Output in College Language Classroom

    Institute of Scientific and Technical Information of China (English)

    张岩

    2010-01-01

    <正>Practice output constitutes an indispensable part in second language learning.Relevant theories like"Interface Position"and"Comprehensible Output"are discussed in order to analyze in detail how this practice can actually facilitate acquisition and finally pave the way for communicative output—a goal all language learners are striving for.

  5. The Role of Output in Grammar Learning

    Institute of Scientific and Technical Information of China (English)

    尹莉; 段薇; 谢璐

    2014-01-01

    In China, English teachers tend to emphasize a lot on the importance of grammar learning because knowledge of gram⁃mar is the base of the competence of communication. This thesis just focuses on how output affects students ’grammar learning by analyzing the role of output in learning of English and the strategies of English learning.

  6. Multi-output programmable quantum processor

    OpenAIRE

    Yu, Yafei; Feng, Jian; Zhan, Mingsheng

    2002-01-01

    By combining telecloning and programmable quantum gate array presented by Nielsen and Chuang [Phys.Rev.Lett. 79 :321(1997)], we propose a programmable quantum processor which can be programmed to implement restricted set of operations with several identical data outputs. The outputs are approximately-transformed versions of input data. The processor successes with certain probability.

  7. DIST/AVC Out-Put Definition.

    Science.gov (United States)

    Wilkinson, Gene L.

    The first stage of development of a management information system for DIST/AVC (Division of Instructional Technology/Audio-Visual Center) is the definition of out-put units. Some constraints on the definition of output units are: 1) they should reflect goals of the organization, 2) they should reflect organizational structure and procedures, and…

  8. Output beam analysis of high power COIL

    Institute of Scientific and Technical Information of China (English)

    Deli Yu(于德利); Fengting Sang(桑凤亭); Yuqi Jin(金玉奇); Yizhu Sun(孙以珠)

    2003-01-01

    As the output power of a chemical oxygen iodine laser (COIL) increases, the output laser beam instabilityappears as the far-field beam spot drift and deformation for the large Fresnel number unstable resonator.In order to interpret this phenomenon, an output beam mode simulation code was developed with the fastFourier transform method. The calculation results show that the presence of the nonuniform gain in COILproduces a skewed output intensity distribution, which causes the mirror tilt and bulge due to the thermalexpansion. With the output power of COIL increases, the mirror surfaces, especially the back surface ofthe scraper mirror, absorb more and more heat, which causes the drift and deformation of far field beamspot seriously. The initial misalignment direction is an important factor for the far field beam spot driftingand deformation.

  9. Crop Insurance, Premium Subsidy and Agricultural Output

    Institute of Scientific and Technical Information of China (English)

    XU Jing-feng; LIAO Pu

    2014-01-01

    This paper studied the effects of crop insurance on agricultural output with an economic growth model. Based on Ramsey-Cass-Koopmans (RCK) model, a basic model of agriculture economic growth was developed. Extending the basic model to incorporate uncertainty and insurance mechanism, a risk model and a risk-insurance model were built to study the inlfuences of risk and crop insurance on agricultural output. Compared with the steady states of the three models, the following results are achieved:(i) agricultural output decreases if we introduce uncertainty into the risk-free model;(ii) crop insurance promotes agriculture economic growth if insurance mechanism is introduced into the risk model;(iii) premium subsidy constantly improves agricultural output. Our contribution is that we studied the effects of crop insurance and premium subsidy from the perspective of economic growth in a dynamic framework, and proved the output promotion of crop insurance theoretically.

  10. Indeterminacy of Spatiotemporal Cardiac Alternans

    CERN Document Server

    Zhao, Xiaopeng

    2007-01-01

    Cardiac alternans, a beat-to-beat alternation in action potential duration (at the cellular level) or in ECG morphology (at the whole heart level), is a marker of ventricular fibrillation, a fatal heart rhythm that kills hundreds of thousands of people in the US each year. Investigating cardiac alternans may lead to a better understanding of the mechanisms of cardiac arrhythmias and eventually better algorithms for the prediction and prevention of such dreadful diseases. In paced cardiac tissue, alternans develops under increasingly shorter pacing period. Existing experimental and theoretical studies adopt the assumption that alternans in homogeneous cardiac tissue is exclusively determined by the pacing period. In contrast, we find that, when calcium-driven alternans develops in cardiac fibers, it may take different spatiotemporal patterns depending on the pacing history. Because there coexist multiple alternans solutions for a given pacing period, the alternans pattern on a fiber becomes unpredictable. Usin...

  11. Is it time for cardiac innervation imaging?

    Energy Technology Data Exchange (ETDEWEB)

    Knuuti, J. [Turku Univ., Turku (Finland) Turku PET Center; Sipola, P. [Kuopio Univ., Kuopio (Finland)

    2005-03-01

    The autonomic nervous system plays an important role in the regulation of cardiac function and the regional distribution of cardiac nerve terminals can be visualized using scintigraphic techniques. The most commonly used tracer is iodine-123-metaiodobenzylguanidine (MIBG) but C-11-hydroxyephedrine has also been used with PET. When imaging with MIBG, the ratio of heart-to-mediastinal counts is used as an index of tracer uptake, and regional distribution is also assessed from tomographic images. The rate of clearance of the tracer can also be measured and indicates the function of the adrenergic system. Innervation imaging has been applied in patients with susceptibility to arrythmias, coronary artery disease, hypertrophic and dilated cardiomyopathy and anthracycline induced cardiotoxicity. Abnormal adrenergic innervation or function appear to exist in many pathophysiological conditions indicating that sympathetic neurons are very susceptible to damage. Abnormal findings in innervation imaging also appear to have significant prognostic value especially in patients with cardiomyopathy. Recently, it has also been shown that innervation imaging can monitor drug-induced changes in cardiac adrenergic activity. Although innervation imaging holds great promise for clinical use, the method has not received wider clinical acceptance. Larger randomized studies are required to confirm the value of innervation imaging in various specific indications.

  12. Development of output user interface software to support analysis

    Science.gov (United States)

    Wahanani, Nursinta Adi; Natsir, Khairina; Hartini, Entin

    2014-09-01

    Data processing software packages such as VSOP and MCNPX are softwares that has been scientifically proven and complete. The result of VSOP and MCNPX are huge and complex text files. In the analyze process, user need additional processing like Microsoft Excel to show informative result. This research develop an user interface software for output of VSOP and MCNPX. VSOP program output is used to support neutronic analysis and MCNPX program output is used to support burn-up analysis. Software development using iterative development methods which allow for revision and addition of features according to user needs. Processing time with this software 500 times faster than with conventional methods using Microsoft Excel. PYTHON is used as a programming language, because Python is available for all major operating systems: Windows, Linux/Unix, OS/2, Mac, Amiga, among others. Values that support neutronic analysis are k-eff, burn-up and mass Pu239 and Pu241. Burn-up analysis used the mass inventory values of actinide (Thorium, Plutonium, Neptunium and Uranium). Values are visualized in graphical shape to support analysis.

  13. Development of output user interface software to support analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wahanani, Nursinta Adi, E-mail: sintaadi@batan.go.id; Natsir, Khairina, E-mail: sintaadi@batan.go.id; Hartini, Entin, E-mail: sintaadi@batan.go.id [Center for Development of Nuclear Informatics - National Nuclear Energy Agency, PUSPIPTEK, Serpong, Tangerang, Banten (Indonesia)

    2014-09-30

    Data processing software packages such as VSOP and MCNPX are softwares that has been scientifically proven and complete. The result of VSOP and MCNPX are huge and complex text files. In the analyze process, user need additional processing like Microsoft Excel to show informative result. This research develop an user interface software for output of VSOP and MCNPX. VSOP program output is used to support neutronic analysis and MCNPX program output is used to support burn-up analysis. Software development using iterative development methods which allow for revision and addition of features according to user needs. Processing time with this software 500 times faster than with conventional methods using Microsoft Excel. PYTHON is used as a programming language, because Python is available for all major operating systems: Windows, Linux/Unix, OS/2, Mac, Amiga, among others. Values that support neutronic analysis are k-eff, burn-up and mass Pu{sup 239} and Pu{sup 241}. Burn-up analysis used the mass inventory values of actinide (Thorium, Plutonium, Neptunium and Uranium). Values are visualized in graphical shape to support analysis.

  14. Application value or high sensitive cardiac troponJn T in acute myocardial infarction.%高敏肌钙蛋白T在急性心肌梗死中的应用价值

    Institute of Scientific and Technical Information of China (English)

    陈志; 盛尚春; 康怡; 逯心敏

    2011-01-01

    Objective The hs-cTnT. Ck-MB. myoglobin (Myo) and troponin T (CTnT) were detected in blood samples in order to discuss the diagnostic value of hs-CTnT in patients with acute myocadial infarcfion, stable angina pain, unstable angina or heart failure Methods Blood samples were collected from patients with acute chest pain within 2 hours after admitted from January 2010 to July 2010. The electrochemical luminescence instrument was used for speeimen testing, the fifth generation of AMl markers hs-CTnT reagent was used to test hs-cTnT. Results hs-CTnT in patients with early AMI was significantly higher than that in other diseases and normal subjects Compared with CTnT, hs-CTnT has statistically significance in acute myocardial infarction and unstable angina,Conclusion The hs-CTnT has more sensitivity than CTnT in the early diagnosis of AMI, and has the same specificity with CTnT. It has a better role in acute myocardial infarction compared with CTnT, while it has the same identifying diagnostic value in unstable angina.%目的 通过对高敏肌钙蛋白T(hs-CTnT)、肌酸激酶同工酶(CK-MB)、肌红蛋白(MYO)、肌钙蛋白T(CTnT)的检测,探讨hs-CTnT在急性心肌梗死、稳定型心绞痛、不稳定型心绞痛及心衰中的诊断应用价值.方法 急性胸痛入院患者103例胸痛发生2 h内采集血样,在罗氏E411型全自动化学发光仪上进行样本检测,hs-CTnT试剂为罗氏公司第五代肌钙蛋白试剂(批号05092728190).结果 (1)hs-CTnT在急性心肌梗死发病早期即明显高于其他疾病和正常人群;(2)hs-CTnT在急性心肌梗死和不稳定型心绞痛中与CTnT相比较,差异有统计学意义.结论 在急性心肌梗死中hs-CTnT较CTnT更敏感,且具有与CTnT相同的特异性,在急性心肌梗死中具有更好的鉴别诊断作用,在不稳定型心绞痛中也同样具有鉴别诊断应用价值.

  15. Case Report: Penetrating Cardiac Injury

    Directory of Open Access Journals (Sweden)

    Adem Grbolar

    2013-10-01

    Full Text Available Summary: Penetrating cardiac injurys caused by gunshots and penetrating tools have high mortality rates. The way of injury, how the cardiac area is effected and the presence of cardiac tamponadecauses mortality in different rates. However the better treatment quality of hospitals, increasingoperative techniques, and internel care unit quality has not been change during the years. Searching the literature, we want to present a 42 years old male patient whowas injured by knife and had a 1 cm skin wound on chest with cardiac tamponade. After sternotomy a 7 cm laseration was observed in heart. Cardioraphy was performed.

  16. Cardiac surgery for Kartagener syndrome.

    Science.gov (United States)

    Tkebuchava, T; von Segesser, L K; Niederhäuser, U; Bauersfeld, U; Turina, M

    1997-01-01

    Two patients (one girl, one boy) with Kartagener syndrome (situs inversus, bronchiectasis, sinusitis), despite pulmonary problems and associated congenital cardiac anomalies, were operated on at the ages of 4 years and 7 years, respectively. They had had previous palliative treatment at the age of 3 months and 1.3 years, respectively. Both postoperative periods after total correction were without significant complications. Long-term follow-up was available for 9 and 19 years, respectively, with no manifestations of heart insufficiency. Both patients are physically active, and neither requires cardiac medication. Patients with Kartagener syndrome and associated congenital cardiac anomalies can successfully undergo multiple cardiac operations with good long-term outcome.

  17. Cardiac MRI for myocardial ischemia.

    LENUS (Irish Health Repository)

    Daly, Caroline

    2013-01-01

    Proper assessment of the physiologic impact of coronary artery stenosis on the LV myocardium can affect patient prognosis and treatment decisions. Cardiac magnetic resonance imaging (CMR) assesses myocardial perfusion by imaging the myocardium during a first-pass transit of an intravenous gadolinium bolus, with spatial and temporal resolution substantially higher than nuclear myocardial perfusion imaging. Coupled with late gadolinium enhancement (LGE) imaging for infarction during the same imaging session, CMR with vasodilating stress perfusion imaging can qualitatively and quantitatively assess the myocardial extent of hypoperfusion from coronary stenosis independent of infarcted myocardium. This approach has been validated experimentally, and multiple clinical trials have established its diagnostic robustness when compared to stress single-photon emission computed tomography. In specialized centers, dobutamine stress CMR has been shown to have incremental diagnostic value above stress echocardiography due to its high imaging quality and ability to image the heart with no restriction of imaging window. This paper reviews the technical aspects, diagnostic utility, prognostic values, challenges to clinical adaptation, and future developments of stress CMR imaging.

  18. 彩色多普勒超声在非高危胎儿产前心脏筛查中的临床价值%Clinical value of color Doppler ultrasound in prenatal cardiac screening of non-high risk fetus

    Institute of Scientific and Technical Information of China (English)

    彭雪芳; 余卫国; 杨淑君

    2013-01-01

    Objective To investigate the clinical diagnostic value of color Doppler ultrasound in prenatal cardiac screening of non-high risk fetus, so as to reduce the birth rate of neonate with congenital heart disease and peri-neonate mortality as much as possible.Methods The clinical materials of 3780 non-high risk fetus in gestational period of 18-24 weeks monitored in the 421st Hospital of PLA from July 2009 to December 2011 were retrospectively analyzed.These fetuses were screened by combination of left and right ventricular outflow tract section, and four-chamber heart section methods.Results Confirmed by induced labor fetus autopsy and post-natal follow-up, 26 fetus with congenital heart disease were founded (including 12 cases of severe congenital heart disease), the overall incidence of cardiac malformations was 6.9‰; twenty-four cases were confirmed by prenatal Doppler ultrasound screening, two cases (1 case of tetralogy of Fallot, 1 case of ventricular septal defect) were missed, prenatal ultrasound detection rate of 92.3%.Conclusion Color Doppler ultrasound can obtain satisfactory fetal heart sonographic image with clear fetal heart structure, can detect most fetal cardiac malformations, is the preferred method of prenatal screening for fetal congenital heart disease, and has important clinical value in non-high-risk prenatal fetal heart screening.%目的 探讨彩色多普勒超声在非高危胎儿产前心脏筛查中的临床诊断价值,以便尽可能地降低先天性心脏病患儿的出生率及围生儿死亡率.方法 回顾性分析2009年6月~2011年12月解放军第四二一医院联合应用左、右室流出道切面和四腔心切面法对孕18~24周的非高危胎儿进行心脏筛查的3780例临床资料.结果 经引产尸解及产后随访证实,本组共检出先天性心脏病胎儿26例(其中严重先天性脏病12例),心脏畸形的总发生率为6.9‰.24例经产前多普勒超声筛查检出,漏诊2例(法洛四联症1

  19. High output piezo/triboelectric hybrid generator.

    Science.gov (United States)

    Jung, Woo-Suk; Kang, Min-Gyu; Moon, Hi Gyu; Baek, Seung-Hyub; Yoon, Seok-Jin; Wang, Zhong-Lin; Kim, Sang-Woo; Kang, Chong-Yun

    2015-01-01

    Recently, piezoelectric and triboelectric energy harvesting devices have been developed to convert mechanical energy into electrical energy. Especially, it is well known that triboelectric nanogenerators have a simple structure and a high output voltage. However, whereas nanostructures improve the output of triboelectric generators, its fabrication process is still complicated and unfavorable in term of the large scale and long-time durability of the device. Here, we demonstrate a hybrid generator which does not use nanostructure but generates much higher output power by a small mechanical force and integrates piezoelectric generator into triboelectric generator, derived from the simultaneous use of piezoelectric and triboelectric mechanisms in one press-and-release cycle. This hybrid generator combines high piezoelectric output current and triboelectric output voltage, which produces peak output voltage of ~370 V, current density of ~12 μA · cm(-2), and average power density of ~4.44 mW · cm(-2). The output power successfully lit up 600 LED bulbs by the application of a 0.2 N mechanical force and it charged a 10 μF capacitor to 10 V in 25 s. Beyond energy harvesting, this work will provide new opportunities for developing a small, built-in power source in self-powered electronics such as mobile electronics.

  20. Relationship between stroke volume, cardiac output and filling of the heart during tilt

    DEFF Research Database (Denmark)

    Bundgaard-Nielsen, M.; Sorensen, H.; Dalsgaard, M.;

    2009-01-01

    %) in LVEDV because HR increased 3 bpm and CO decreased 0.5 l/min (ns). CONCLUSION: This study confirmed that SV and CO are maximal in resting, supine, healthy humans and decrease during HUT. However, 90 degrees HDT was associated with increased LVEDV and induced a reduction in SV Udgivelsesdato: 2009/11...

  1. Allometric scaling of decompression sickness risk in terrestrial mammals; cardiac output explains risk of decompression sickness

    Science.gov (United States)

    Fahlman, Andreas

    2017-02-01

    A probabilistic model was used to predict decompression sickness (DCS) outcome in pig (70 and 20 kg), hamster (100 g), rat (220 g) and mouse (20 g) following air saturation dives. The data set included 179 pig, 200 hamster, 360 rat, and 224 mouse exposures to saturation pressures ranging from 1.9–15.2 ATA and with varying decompression rates (0.9–156 ATA • min‑1). Single exponential kinetics described the tissue partial pressures (Ptiss) of N2: Ptiss =  ∫(Pamb – Ptiss) • τ‑1 dt, where Pamb is ambient N2 pressure and τ is a time constant. The probability of DCS [P(DCS)] was predicted from the risk function: P(DCS) = 1‑e‑r, where r = ∫(PtissN2 ‑ Thr ‑ Pamb) • Pamb–1 dt, and Thr is a threshold parameter. An equation that scaled τ with body mass included a constant (c) and an allometric scaling parameter (n), and the best model included n, Thr, and two c. The final model provided accurate predictions for 58 out of 61 dive profiles for pig, hamster, rat, and mouse. Thus, body mass helped improve the prediction of DCS risk in four mammalian species over a body mass range covering 3 orders of magnitude.

  2. Is pulmonary gas exchange during exercise in hypoxia impaired with the increase of cardiac output?

    DEFF Research Database (Denmark)

    Calbet, J.A.; Robach, P.; Lundby, C.

    2008-01-01

    -a)DO(2) is accentuated. Using the multiple inert gas elimination technique it has been shown that during exercise in acute hypoxia the contribution of ventilation-perfusion inequality to (A-a)DO(2) is rather small and in the absence of pulmonary edema intrapulmonary shunts can be ruled out. This implies...

  3. Evaluation of cerebral electrical activity and cardiac output after patent ductus arteriosus ligation in preterm infants.

    LENUS (Irish Health Repository)

    Leslie, A T F S

    2013-11-01

    To characterize and investigate the relationship between systemic blood flow and pre- and postoperative cerebral electrical activity in preterm neonates undergoing patent ductus arteriosus (PDA) ligation.

  4. Impact of extracorporeal blood flow rate on blood pressure, pulse rate and cardiac output during haemodialysis

    DEFF Research Database (Denmark)

    Schytz, Philip Andreas; Mace, Maria Lerche; Soja, Anne Merete Boas

    2015-01-01

    BACKGROUND: If blood pressure (BP) falls during haemodialysis (HD) [intradialytic hypotension (IDH)] a common clinical practice is to reduce the extracorporeal blood flow rate (EBFR). Consequently the efficacy of the HD (Kt/V) is reduced. However, only very limited knowledge on the effect of redu...

  5. Monitoring cardiac output during hyperbaric oxygen treatment of haemodynamically unstable patients

    DEFF Research Database (Denmark)

    Hansen, Marco Bo; Treschow, Frederik; Skielboe, Martin

    2013-01-01

    Patients suffering from necrotizing fasciitis (NF) are often haemodynamically unstable and require extended monitoring of cardiovascular parameters; yet this is limited during hyperbaric oxygen treatment (HBOT). We aimed to evaluate the use and safety of transoesophageal Doppler (TED) monitoring...

  6. Mechanisms of increase in cardiac output during acute weightlessness in humans

    DEFF Research Database (Denmark)

    Petersen, Lonnie G; Damgaard, Morten; Petersen, Johan Casper Grove;

    2011-01-01

    by parabolic flight increased CO by 1.7 ± 0.4 l/min (P ... in CO during acute 0 G in seated humans. A Bainbridge-like reflex could be the mechanism for the HR-induced increase in CO during 0 G in particular in supine subjects....

  7. High Output Cardiac Failure Resolving after Repair of AV Fistula in a Six-Month-Old

    OpenAIRE

    Uygar Teomete; Rubee Anne Gugol; Holly Neville; Ozgur Dandin; Ming-Lon Young

    2016-01-01

    Background. Acquired AVF in pediatrics are commonly caused by iatrogenic means, including arterial or venous punctures. These fistulae can cause great hemodynamic stress on the heart as soon as they are created. Case. A six-month-old 25-week gestation infant was referred for respiratory distress. Initial exam revealed tachypnea, tachycardia, and hypertension. There was a bruit noted on her left arm. An ultrasound showed an arteriovenous fistula. Its location, however, precluded intervention b...

  8. Sublingual nitroglycerin used in routine tilt testing provokes a cardiac output-mediated vasovagal response

    NARCIS (Netherlands)

    Gisolf, J.; Westerhof, B.E.; Dijk, N. van; Wesseling, K.H.; Wieling, W.; Karemaker, J.M.

    2004-01-01

    Objectives We set out to determine the effect of sublingual nitroglycerin (NTG), as used during routine tilt testing in patients with unexplained syncope, on hemodynamic characteristics and baroreflex control of heart rate (HR) and systemic vascular resistance (SVR). Background Nitroglycerin is used

  9. Estimation of cardiac output and total peripheral resistance in preterm infants by arterial waveform analysis.

    Science.gov (United States)

    Zhang, Ying; Chan, Gregory S H; Tracy, Mark B; Hinder, Murray; Redmond, Stephen J; Savkin, Andrey V; Lovell, Nigel H

    2013-01-01

    This study investigated whether arterial blood pressure waveform analysis could be useful for estimating left ventricular outflow (LVO) and total peripheral resistance (TPR) in preterm infants. A cohort of 27 infants were studied, with 89 measurements of left ventricular outflow (LVO) using Doppler echocardiography and arterial pressure using catheters, performed in 0, 12, 24 and 36 hours after birth. TPR was computed as mean arterial pressure divided by LVO. The diastolic decay rate (1/τ) was obtained via fitting an exponential function to the last one third of each arterial pulse, with the mean rate computed from 50 pulses selected from each infant. This decay rate was considered to be inversely related to TPR while positively related to LVO. The results of regression analysis have confirmed that the diastolic decay rate had significant positive and negative relationships with LVO and TPR respectively(r = 0.383, P = 0.0002 and r = -0.379, P = 0.0002 respectively). These preliminary results demonstrated the potential utility of arterial pressure waveform analysis for estimating LVO and TPR in preterm infants, but more advanced multi-parameter models may be needed to improve accuracy of the estimation.

  10. Effects of ventilation on cardiac output determined by inert gas rebreathing

    DEFF Research Database (Denmark)

    Damgaard, Morten; Norsk, Peter

    2005-01-01

    had no effects. CO was 1.0 +/- 0.2 l min(-1) higher when, rebreathing was performed after a forced expiration than following a normal tidal expiration. Serial determinations of CO required a 3-min interval between the measurements to avoid effects of recirculation of N(2)O. Changing RF from 15 to 30...... breaths min(-1) or adding serial dead space by up to 600 ml did not affect the determination of CO. In conclusion, the rebreathing procedure for determination of CO at rest should be performed following a normal tidal expiration with a rebreathing bag volume of between 1.5 and 2.5 l and with manoeuvres...

  11. Output Regulation of the Arneodo Chaotic System

    Directory of Open Access Journals (Sweden)

    Sundarapandian Vaidyanathan

    2010-08-01

    Full Text Available This paper solves the problem of regulating the output of the Arneodo chaotic system (1981, which is one of the paradigms of chaotic dynamical systems. Explicitly, using the state feedback control laws, the output of the Arneodo chaotic system is regulated so as to track constant reference signals as well as to track periodic reference signals. The control laws are derived using the regulator equations of Byrnes and Isidori (1990, which provide the solution of the output regulation problem for nonlinear control systems involving neutrally stable exosystem dynamics. Numerical results are shown to verify the results.

  12. 心脏超声筛查在胎儿先天性心脏病诊断中的应用价值%Value evaluation of fetal cardiac ultrasound in the detection of congenital heart disease

    Institute of Scientific and Technical Information of China (English)

    黄聚财; 蔡媛媛; 赖江琼

    2016-01-01

    Objective To compare the value of conventional ultrasound and conventional ultrasound in the diagnosis of fetal congenital heart disease, and to analyze the risk factors of fetal congenital heart disease, and to reduce the incidence of neonatal con⁃genital heart disease. Methods A total of 4000 pregnant women April 2013 to August 2014 in our hospital were randomly divided into the observation group and the control group according to the digital table method. The observation group gave conventional ultrasound and fetal heart examination. Patients in control group were treated with routine ultrasound examination. To compare the test results with the actual situation;and to screen out risk factors of pregnant women with fetal congenital heart disease. Results 9 cases of congenital heart disease were detected by conventional ultrasound and fetal heart examination, of 8 cases were diagnosed with congenital heart dis⁃ease, and the diagnostic accuracy rate was 90%;3 cases were diagnosed with congenital heart disease by conventional ultrasound ex⁃amination, and the diagnostic accuracy rate was 40%. The difference was statistically significant ( P<0.05) . Conclusion The accu⁃racy of routine ultrasound examination and fetal heart examination in screening of congenital heart disease is higher than that of the con⁃trol group, which is worthy of clinical application.%目的:比较常规超声检查与常规超声检查加胎心检查在胎儿先天性心脏病诊断中的应用价值,并分析胎儿先天性心脏病的危险因素。方法以2013年4月-2014年8月在我院健康检查的4000名孕妇为研究对象,按照数字数表法随机分为观察组和对照组。观察组采用常规超声检查+胎心检查,对照组采用常规超声检查,比较两组的检查结果,对筛查出怀有先天性心脏病胎儿的孕妇进行危险因素调查。结果常规超声检查加胎心产前检查发现9例先天性心脏病胎儿,漏检1

  13. Detonation Output Properties of D-shape Structure

    Directory of Open Access Journals (Sweden)

    Ji-feng WEI

    2014-09-01

    Full Text Available The detonation wave propagation and output properties have been analyzed for D-shape structure. Four initiation modes were designed to compare wavefront profiles and output pressure distribution. Simulation results show that three-array-nine-point initiation mode (Mode-III brings about the most match-up wave front for D-shape structure. Detonation output properties have great influence on fragment ejection velocity and distribution density. The statistical results reveal that fragment parameters of Mode-III are the largest. Compared with Mode-III, the kinetic energies of other three modes decrease by 31.6 per cent, 19.6 per cent, 4.5 per cent, respectively. The computational values and normal curve of fragments distribution are obtained. From these analyses, it can be concluded that initiation mode has great influence on output parameters of fragments. With the optimal initiation Mode-III, ideal hitting angle should be within the range of -10° to 10°, the probability of distribution density would be close to 70 per cent.Defence Science Journal, Vol. 64, No. 5, September 2014, pp.484-489, DOI:http://dx.doi.org/10.14429/dsj.64.4746

  14. Use of Follicular Output Rate to Predict Intracytoplasmic Sperm Injection Outcome

    Science.gov (United States)

    Rehman, Rehana; Mustafa, Rozina; Baig, Mukhtiar; Arif, Sara; Hashmi, Muhammad Faisal

    2016-01-01

    Background The measurement of follicular output rate (FORT) has been proposed as a good indicator for evaluating follicular response to the exogenous recombinant folliclestimulating hormone (rFSH). This places FORT as a promising qualitative marker for ovarian function. The objective of the study was to determine FORT as a predictor of oocyte competence, embryo quality and clinical pregnancy after intracytoplasmic sperm injection (ICSI). Materials and Methods This prospective study was carried out on a group of infer- tile females (n=282) at Islamabad Clinic Serving Infertile Couples, Islamabad, Pakistan, from June 2010 till August 2013. Downregulated females were stimulated in injection gonadotropins and on ovulation induction day, pre-ovulatory follicle count (PFC) was determined using transvaginal ultrasound scan (TVUS), and FORT was determined as a ratio of PFC to antral follicle count (AFC)×100. Group I consisted of females with a negative pregnancy test, while group II had a positive pregnancy test that was confirmed with the appearance of fetal cardiac activity. Linear regression analyses of categorical variables of clinical pregnancy along with other independent variables, including FORT, were performed using SPSS version 15.0. Results Pregnancy occurred in 101/282 women who were tested, recording a clinical pregnancy rate of about 35.8%. FORT values were higher in group II as compared to group I females (P=0.0001). In multiple regression analysis, 97.7, 87.1, 78.2, and 83.4% variations were explained based on the number of retrieved oocytes per patients, number of metaphase II oocytes retrieved, number of fertilized oocytes, and number of cleaved embryos, respectively, indicating FORT as an independent predictor. Conclusion FORT is a predictor of oocyte competence in terms of a number of retrieved, mature and fertilized oocytes. It also gives information about the number of cleaved embryos and clinical pregnancy rate. PMID:27441049

  15. 肌钙蛋白Ⅰ对老年不稳定型心绞痛患者危险分层的判断价值%The value of cardiac troponin Ⅰ in risk stratification of elderly patients with unstable angina pectoris

    Institute of Scientific and Technical Information of China (English)

    党彦平; 耿秀双

    2009-01-01

    Objective To study the value of serum troponin I(cTnI)in risk stratification of elderly patients with unstable angina pectoris(UAP).Methods Serum cTnI levels were measured in 22 healthy subjects(control group),27 stable angina peetoris(SAP)and 72 UAP elderly patients,respectively.Cardiac events(non fatal myocardial infarction,cardiac sudden death)were observed within 1 month of hospitalization.Serum cTnI≥1.5 μg/L was considered as the cutoff level for myocardial damage.Results Serum cTnI levels in the UAP group were higher than those in the SAP and control group [(1.96±0.61)μg/L,(0.68±0.19)μg/L and(0.46±0.10)μg/L,respectively](P<0.01).In the UAP group,serum cTnI levels increased with increase of Braunwald classification class[(1.25±0.38)μg/L,(2.12±0.34)μg/L and(3.06±0.72)μg/L,respectively](P<0.05).In Braunwald class Ⅲ patients,the rate of cardiac events in patients with serum cTnI≥1.5 μg/L was much higher than that in those with cTnI<1.5μg/L(16.7%vs 6.3%,P<0.05),risk ratio 2.05(95%confidence limit 1.02-9.78).The positive predictive value of serum cTnI≥1.5μg/L for cardiac events was 44.3%and the negative predictive value was 84.8%.Conclusions Detection of serum cTnI has clinical value in risk stratification of elderly atients with UAP.%目的 探讨心脏肌钙蛋白Ⅰ(cTnI)对老年不稳定型心绞痛(UAP)患者危险分层的价值.方法 对72例老年UAP患者、27例稳定型心绞痛(SAP)患者及22例健康对照者分别进行血清cTnI测定,并观察住院1个月内心脏事件发生情况.结果 UAP组血清cTnI值为(1.96±0.61)μg/L,明显高于SAP组的(0.68±0.19)μg/L及对照组的(0.46±0.10)μg/L(P均<0.01).UAP组内,随着Braunwald临床分级增高,Ⅰ~Ⅲ级血清cTnI值相应增高[分别为(1.25±0.38)μg/L、(2.12±0.34)μg/L及(3.06±0.72)μg/L](P<0.05).对照组、SAP组及Braunwald Ⅰ级UAP患者无一例发生心脏事件;18例Ⅱ级患者中,1例(其血清cTnI≥1.5μg/L)发

  16. Histamine induces postprandian tachycardia through a direct effect on cardiac H2-receptors in pythons

    DEFF Research Database (Denmark)

    Jensen, Nini Skovgaard; Møller, Kate; Gesser, Hans

    2009-01-01

    snakes histamine caused a systemic vasodilatation and a marked increase in heart rate and cardiac output mediated through a direct effect on H2-receptors. Our study strongly indicates that histamine regulates heart rate during the initial phase of digestion in pythons. This study describes a novel...

  17. Correlação entre gasometria atrial direita e índice cardíaco no pós-operatório de cirurgia cardíaca Correlation between right atrial venous blood gasometry and cardiac index in cardiac surgery postoperative period

    Directory of Open Access Journals (Sweden)

    João Jackson Duarte

    2010-06-01

    ( a-v O2. Afterwards, these parameters were compared with the cardiac index determined by thermodilution. RESULTS: There was good correlation between SvO2, C(avO2 of the venous right atrial blood and cardiac index meansured by termodiluition method, with sensibility and especificity good and high positive predict value and negative predict value. The PvO2 demonstrated poor sensibility in the estimative of low output. CONCLUSION: In cardiac surgery postoperative, the SvO2and the C(a-vO2 were safe parameters correlated with low cardiac output. The PvO2 demonstrated poor sensibility in the estimative of low output in postoperative cardiac surgery.

  18. Output Measures and Library Space Planning.

    Science.gov (United States)

    Lushington, Nolan

    1987-01-01

    Draws some initial connections between library performance measures and library space planning and collection management. Output measure surveys are suggested for establishing hierarchies of use and appropriate design of environments for housing the collection. Four references are listed. (MES)

  19. Scaling of global input-output networks

    Science.gov (United States)

    Liang, Sai; Qi, Zhengling; Qu, Shen; Zhu, Ji; Chiu, Anthony S. F.; Jia, Xiaoping; Xu, Ming

    2016-06-01

    Examining scaling patterns of networks can help understand how structural features relate to the behavior of the networks. Input-output networks consist of industries as nodes and inter-industrial exchanges of products as links. Previous studies consider limited measures for node strengths and link weights, and also ignore the impact of dataset choice. We consider a comprehensive set of indicators in this study that are important in economic analysis, and also examine the impact of dataset choice, by studying input-output networks in individual countries and the entire world. Results show that Burr, Log-Logistic, Log-normal, and Weibull distributions can better describe scaling patterns of global input-output networks. We also find that dataset choice has limited impacts on the observed scaling patterns. Our findings can help examine the quality of economic statistics, estimate missing data in economic statistics, and identify key nodes and links in input-output networks to support economic policymaking.

  20. Oil Refining Giants to Cut Output

    Institute of Scientific and Technical Information of China (English)

    Zhang Dingmin

    2002-01-01

    @@ China's refined oil product output rose slightly in the first five months of this year on strong demand,but the two biggest domestic producers plan to cut production rates in an attempt to bolster the sluggish price.

  1. OFFSHORE OIL OUTPUT MORE THAN SCHEDULED

    Institute of Scientific and Technical Information of China (English)

    1997-01-01

    @@ China Offshore Oil Nan Hai East Corp (CONHE) is one of four subsidiaries of the China National Offshore Oil Corp.The first-quarter output was an encouraging 220 000 tons more than the planned goal for that period.

  2. Memory-based parallel data output controller

    Science.gov (United States)

    Stattel, R. J.; Niswander, J. K. (Inventor)

    1984-01-01

    A memory-based parallel data output controller employs associative memories and memory mapping to decommutate multiple channels of telemetry data. The output controller contains a random access memory (RAM) which has at least as many address locations as there are channels. A word counter addresses the RAM which provides as it outputs an encoded peripheral device number and a MSB/LSB-first flag. The encoded device number and a bit counter address a second RAM which contains START and STOP flags to pick out the required bits from the specified word number. The LSB/MSB, START and STOP flags, along with the serial input digital data go to a control block which selectively fills a shift register used to drive the parallel data output bus.

  3. Coupling output of multichannel high power microwaves

    Science.gov (United States)

    Li, Guolin; Shu, Ting; Yuan, Chengwei; Zhang, Jun; Yang, Jianhua; Jin, Zhenxing; Yin, Yi; Wu, Dapeng; Zhu, Jun; Ren, Heming; Yang, Jie

    2010-12-01

    The coupling output of multichannel high power microwaves is a promising technique for the development of high power microwave technologies, as it can enhance the output capacities of presently studied devices. According to the investigations on the spatial filtering method and waveguide filtering method, the hybrid filtering method is proposed for the coupling output of multichannel high power microwaves. As an example, a specific structure is designed for the coupling output of S/X/X band three-channel high power microwaves and investigated with the hybrid filtering method. In the experiments, a pulse of 4 GW X band beat waves and a pulse of 1.8 GW S band microwave are obtained.

  4. Hypokalemia and sudden cardiac death

    DEFF Research Database (Denmark)

    Kjeldsen, Keld

    2010-01-01

    Worldwide, approximately three million people suffer sudden cardiac death annually. These deaths often emerge from a complex interplay of substrates and triggers. Disturbed potassium homeostasis among heart cells is an example of such a trigger. Thus, hypokalemia and, also, more transient...... of fatal arrhythmia and sudden cardiac death a patient is, the more attention should be given to the potassium homeostasis....

  5. The Danish Cardiac Rehabilitation Database

    DEFF Research Database (Denmark)

    Zwisler, Ann-Dorthe; Rossau, Henriette Knold; Nakano, Anne

    2016-01-01

    AIM OF DATABASE: The Danish Cardiac Rehabilitation Database (DHRD) aims to improve the quality of cardiac rehabilitation (CR) to the benefit of patients with coronary heart disease (CHD). STUDY POPULATION: Hospitalized patients with CHD with stenosis on coronary angiography treated with percutane...

  6. Biosynthesis of cardiac natriuretic peptides

    DEFF Research Database (Denmark)

    Goetze, Jens Peter

    2010-01-01

    . An inefficient post-translational prohormone maturation will also affect the biology of the cardiac natriuretic peptide system. This review aims at summarizing the myocardial synthesis of natriuretic peptides focusing on B-type natriuretic peptide, where new data has disclosed cardiac myocytes as highly...

  7. [Cardiac myxoma with cerebral metastases].

    Science.gov (United States)

    Bazin, A; Peruzzi, P; Baudrillard, J C; Pluot, M; Rousseaux, P

    1987-01-01

    A 56 year old woman developed multiple metastases in the cerebrum and cerebellum, four years after cardiac intervention on a left atrial myxoma. The absence of stroke is noteworthy. Multiple high density lesions with contrast enhancement were seen by CT scan, suggesting metastatic neoplasms. Histological examination confirmed the diagnosis of metastases of cardiac myxoma. Only four cases were recorded in the literature.

  8. Health Instruction Packages: Cardiac Anatomy.

    Science.gov (United States)

    Phillips, Gwen; And Others

    Text, illustrations, and exercises are utilized in these five learning modules to instruct nurses, students, and other health care professionals in cardiac anatomy and functions and in fundamental electrocardiographic techniques. The first module, "Cardiac Anatomy and Physiology: A Review" by Gwen Phillips, teaches the learner to draw…

  9. Pneumothorax in cardiac pacing

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard;

    2012-01-01

    AIM: To identify risk factors for pneumothorax treated with a chest tube after cardiac pacing device implantation in a population-based cohort.METHODS AND RESULTS: A nationwide cohort study was performed based on data on 28 860 patients from the Danish Pacemaker Register, which included all Danish...... patients who received their first pacemaker (PM) or cardiac resynchronization device from 1997 to 2008. Multiple logistic regression was used to estimate adjusted odds ratios (aOR) with 95% confidence intervals for the association between risk factors and pneumothorax treated with a chest tube. The median...... age was 77 years (25th and 75th percentile: 69-84) and 55% were male (n = 15 785). A total of 190 patients (0.66%) were treated for pneumothorax, which was more often in women [aOR 1.9 (1.4-2.6)], and in patients with age >80 years [aOR 1.4 (1.0-1.9)], a prior history of chronic obstructive pulmonary...

  10. Leadership in cardiac surgery.

    Science.gov (United States)

    Rao, Christopher; Patel, Vanash; Ibrahim, Michael; Ahmed, Kamran; Wong, Kathie A; Darzi, Ara; von Segesser, Ludwig K; Athanasiou, Thanos

    2011-06-01

    Despite the efficacy of cardiac surgery, less invasive interventions with more uncertain long-term outcomes are increasingly challenging surgery as first-line treatment for several congenital, degenerative and ischemic cardiac diseases. The specialty must evolve if it is to ensure its future relevance. More importantly, it must evolve to ensure that future patients have access to treatments with proven long-term effectiveness. This cannot be achieved without dynamic leadership; however, our contention is that this is not enough. The demands of a modern surgical career and the importance of the task at hand are such that the serendipitous emergence of traditional charismatic leadership cannot be relied upon to deliver necessary change. We advocate systematic analysis and strategic leadership at a local, national and international level in four key areas: Clinical Care, Research, Education and Training, and Stakeholder Engagement. While we anticipate that exceptional individuals will continue to shape the future of our specialty, the creation of robust structures to deliver collective leadership in these key areas is of paramount importance.

  11. Analysis on Value of X-Ray in the Diagnosis of Early Left Cardiac Insufficiency in Patients with Hypertensive Heart Disease%高血压性心脏病早期左心功能不全的X线诊断价值分析

    Institute of Scientific and Technical Information of China (English)

    翟锦添; 张训平

    2016-01-01

    目的 观察高血压性心脏病早期左心功能不全的X线诊断情况, 分析X线的临床诊断价值. 方法 选取2010年12月到2014年12月期间在我院检查确诊的高血压性心脏病早期左心功能不全患者300例作为研究对象. 300例患者根据有无临床症状分为有症状组和无症状组, 有症状组208例患者, 无症状组92例患者, 所有患者分别进行X线检查和超声检查, 对比两组患者的诊断情况. 结果 有症状组X线检查出202例患者, 无症状组检查出72例患者; 有症状组超声检查出206例患者, 无症状组检查出78例患者; X线检查与超声检查的结果基本一致, 差异无统计学意义 (P>0.05); 有症状组的检出率明显高于无症状组的检出率, 差异具有统计学意义 (P0.05). The detection rate of symptomatic group was significantly higher than that of asymptomatic group (P<0.05). Clinical representation of X-ray for 300 cases showed that 260 cases of superior vein dilatation, 70 cases of pulmonary blood flow redistribution, 195 cases of the lung fuzzy, 115 cases of the subpleural edema, 60 cases of rib phrenic angle drainage, 45 cases of Kerley's B line, 235 cases of cardiac enlargement. Conclusions X-ray has high detection rate for early left cardiac insufficiency in patients with hypertensive heart disease, especially for patients with clinical symptoms, which has a certain clinical application value.

  12. Chronic changes of hematocrit value alter blood pressure and glomerular filtration in spontaneously hypertensive rats

    Directory of Open Access Journals (Sweden)

    Milanović S.

    2012-01-01

    Full Text Available Many studies in hypertensive humans and animals have shown that increased blood viscosity is in direct relation with essential hypertension. The aim of our studies was to investigate the effects of chronic hematocrit value changes on arterial blood pressure and kidney function in genetically induced hypertension. To this end, we studied the effects of several interventions, designed to increase/decrease hematocrit, on hemodynamic parameters, vascular reactivity, glomerular filtration and renal function curve in spontaneously hypertensive rats (SHR. Results of our study show that chronic hematocrit value elevation increases blood pressure and peripheral vascular resistance in SHR. On the other hand, chronic hematocrit lowering elucidates blood pressure and peripheral vascular resistance decrease followed by cardiac output rising. Both hematocrit value changes significantly reduce vasodilatory vascular response. Hematocrit lowering induces acute renal failure. Sodium excretion is shifted to higher blood pressure values in high hematocrit value animals and opposite - lower blood pressure values in low hematocrit value animals. Repeated transfusions develop salt sensitive malignant hypertension in SHR. Further studies are necessary to evaluate the degree of kidney damage after chronic hematocrit value changes in SHR.

  13. Cardiac resynchronization therapy for chronic heart failure in China: guideline and practice

    Institute of Scientific and Technical Information of China (English)

    HUA Wei

    2010-01-01

    @@ The value of cardiac resynchronization therapy (CRT)in chronic heart failure has been well recognized around the world. Multi-center clinical trials have confirmed that CRT not only can improve cardiac function and quality of life, but also reduce mortality and improve the prognosis in patients with advanced heart failure and ventricular dyssynchrony.

  14. Preoperative cardiac computed tomography for demonstration of congenital cardiac septal defect in adults

    Energy Technology Data Exchange (ETDEWEB)

    Eom, Hye-Joung; Yang, Dong Hyun; Kang, Joon-Won; Lim, Tae-Hwan [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Cardiac Imaging Center, Asan Medical Center, Seoul (Korea, Republic of); Kim, Dae-Hee; Song, Jong-Min; Kang, Duk-Hyun; Song, Jae-Kwan [University of Ulsan College of Medicine, Department of Cardiology and Heart Institute, Cardiac Imaging Center, Asan Medical Center, Seoul (Korea, Republic of); Kim, Joon Bum; Jung, Sung-Ho; Choo, Suk Jung; Chung, Cheol Hyun; Lee, Jae Won [University of Ulsan College of Medicine, Department of Cardiothoracic surgery, Cardiac Imaging Center, Asan Medical Center, Seoul (Korea, Republic of)

    2015-06-01

    We aimed to evaluate the role of preoperative cardiac computed tomography (CT) for adults with congenital cardiac septal defect (CSD). Sixty-five consecutive patients who underwent preoperative CT and surgery for CSD were included. The diagnostic accuracy of CT and the concordance rate of the subtype classification of CSD were evaluated using surgical findings as the reference standard. Sixty-five patients without CSD who underwent cardiac valve surgery were used as a control group. An incremental value of CT over echocardiography was described retrospectively. Sensitivity and specificity of CT for diagnosis of CSD were 95 % and 100 %, respectively. The concordance rate of subtype classification was 91 % in CT and 92 % in echocardiography. The maximum size of the defect measured by CT correlated well with surgical measurement (r = 0.82), and the limit of agreement was -0.9 ± 7.42 mm. In comparison with echocardiography, CT was able to detect combined abnormalities in three cases, and exclusively provided correct subtype classification or clarified suspected abnormal findings found on echocardiography in seven cases. Cardiac CT can accurately demonstrates CSD in preoperative adult patients. CT may have an incremental role in preoperative planning, particularly in those with more complex anatomy. (orig.)

  15. Congestive kidney failure in cardiac surgery: the relationship between central venous pressure and acute kidney injury.

    Science.gov (United States)

    Gambardella, Ivancarmine; Gaudino, Mario; Ronco, Claudio; Lau, Christopher; Ivascu, Natalia; Girardi, Leonard N

    2016-11-01

    Acute kidney injury (AKI) in cardiac surgery has traditionally been linked to reduced arterial perfusion. There is ongoing evidence that central venous pressure (CVP) has a pivotal role in precipitating acute renal dysfunction in cardiac medical and surgical settings. We can regard this AKI driven by systemic venous hypertension as 'kidney congestive failure'. In the cardiac surgery population as a whole, when the CVP value reaches the threshold of 14 mmHg in postoperative period, the risk of AKI increases 2-fold with an odds ratio (OR) of 1.99, 95% confidence interval (95% CI) of 1.16-3.40. In cardiac surgery subsets where venous hypertension is a hallmark feature, the incidence of AKI is higher (tricuspid disease 30%, carcinoid valve disease 22%). Even in the non-chronically congested coronary artery bypass population, CVP measured 6 h postoperatively showed significant association to renal failure: risk-adjusted OR for AKI was 5.5 (95% CI 1.93-15.5; P = 0.001) with every 5 mmHg rise in CVP for patients with CVP <9 mmHg; for CVP increments of 5 mmHg above the threshold of 9 mmHg, the risk-adjusted OR for AKI was 1.3 (95% CI 1.01-1.65; P = 0.045). This and other clinical evidence are discussed along with the underlying pathophysiological mechanisms, involving the supremacy of volume receptors in regulating the autonomic output in hypervolaemia, and the regional effect of venous congestion on the nephron. The effect of CVP on renal function was found to be modulated by ventricular function class, aetiology and acuity of venous congestion. Evidence suggests that acute increases of CVP should be actively treated to avoid a deterioration of the renal function, particularly in patients with poor ventricular fraction. Besides, the practice of treating right heart failure with fluid loading should be avoided in favour of other ways to optimize haemodynamics in this setting, because of the detrimental effects on the kidney function.

  16. Correlation of mixed venous and central venous oxygen saturation and its relation to cardiac index

    Directory of Open Access Journals (Sweden)

    Ramakrishna M

    2006-01-01

    Full Text Available Background and Aim: The clinical applicability of substitution of central venous oxygen saturation for mixed venous oxygen saturations in monitoring global tissue hypoxia is still a matter of controversy. Hence aim of the study is comparison of paired samples of mixed venous and central venous oxygen saturation and comparison in relation to cardiac index in varying hemodynamic conditions. Materials and Methods: Prospective clinical observation: Postoperative cardiac surgical ITU: 60 adult p