WorldWideScience

Sample records for cardiac output monitoring

  1. Cardiac output monitoring

    Directory of Open Access Journals (Sweden)

    Mathews Lailu

    2008-01-01

    Full Text Available Minimally invasive and non-invasive methods of estimation of cardiac output (CO were developed to overcome the limitations of invasive nature of pulmonary artery catheterization (PAC and direct Fick method used for the measurement of stroke volume (SV. The important minimally invasive techniques available are: oesophageal Doppler monitoring (ODM, the derivative Fick method (using partial carbon dioxide (CO 2 breathing, transpulmonary thermodilution, lithium indicator dilution, pulse contour and pulse power analysis. Impedance cardiography is probably the only non-invasive technique in true sense. It provides information about haemodynamic status without the risk, cost and skill associated with the other invasive or minimally invasive techniques. It is important to understand what is really being measured and what assumptions and calculations have been incorporated with respect to a monitoring device. Understanding the basic principles of the above techniques as well as their advantages and limitations may be useful. In addition, the clinical validation of new techniques is necessary to convince that these new tools provide reliable measurements. In this review the physics behind the working of ODM, partial CO 2 breathing, transpulmonary thermodilution and lithium dilution techniques are dealt with. The physical and the physiological aspects underlying the pulse contour and pulse power analyses, various pulse contour techniques, their development, advantages and limitations are also covered. The principle of thoracic bioimpedance along with computation of CO from changes in thoracic impedance is explained. The purpose of the review is to help us minimize the dogmatic nature of practice favouring one technique or the other.

  2. Continuous cardiac output and mixed venous oxygen saturation monitoring.

    Science.gov (United States)

    Cariou, A; Monchi, M; Dhainaut, J F

    1998-12-01

    Continuous assessment of cardiac output and SVO2 in the critically ill may be helpful in both the monitoring variations in the patient's cardiovascular state and in determining the efficacy of therapy. Commercially available continuous cardiac output (CCO) monitoring systems are based on the pulsed warm thermodilution technique. In vitro validation studies have demonstrated that this method provides higher accuracy and greater resistance to thermal noise than standard bolus thermodilution techniques. Numerous clinical studies comparing bolus with continuous thermodilution techniques have shown this technique similarly accurate to track each other and to have negligible bias between them. The comparison between continuous thermal and other cardiac output methods also demonstrates good precision of the continuous thermal technique. Accuracy of continuous oximetry monitoring using reflectance oximetry via fiberoptics has been assessed both in vitro and in vivo. Most of the studies testing agreement between continuous SVO2 measurements and pulmonary arterial blood samples measured by standard oximetry have shown good correlation. Continuous SVO2 monitoring is often used in the management of critically ill patients. The most recently designed pulmonary artery catheters are now able to simultaneously measure either SVO2 and CCO or SVO2 and right ventricular ejection fraction. This ability to view simultaneous trends of SVO2 and right ventricular performance parameters will probably allow the clinician to graphically see the impact of volume loading or inotropic therapy over time, as well as the influence of multiple factors, including right ventricular dysfunction, on SVO2. However, the cost-effectiveness of new pulmonary artery catheters application remains still questionable because no established utility or therapeutic guidelines are available.

  3. The normal ranges of cardiovascular parameters in children measured using the Ultrasonic Cardiac Output Monitor.

    Science.gov (United States)

    Cattermole, Giles N; Leung, P Y Mia; Mak, Paulina S K; Chan, Stewart S W; Graham, Colin A; Rainer, Timothy H

    2010-09-01

    The Ultrasonic Cardiac Output Monitor is a noninvasive method of hemodynamic assessment and monitoring in critically ill patients. There are no published reference ranges for normal values in children for this device. This study aimed to establish normal ranges for cardiovascular indices measured using Ultrasonic Cardiac Output Monitor in children aged 0-12 yrs old and to assess interobserver reliability. This was a population-based cross-sectional observational study. Schools and kindergartens in Hong Kong. Chinese children aged up to 12 yrs old. Two operators performed Ultrasonic Cardiac Output Monitor scans on each child together with standard oscillometric measurement of blood pressure and heart rate. Software intrinsic to the Ultrasonic Cardiac Output Monitor device produces values for stroke volume, cardiac output, and systemic vascular resistance. For each parameter, normal ranges were defined as lying between the 2.5th and 97.5th percentiles. Interobserver reliability was assessed with Bland-Altman plots, coefficients of variation, and intraclass correlation. A total of 1,197 Chinese children (55% boys) were scanned. Normal ranges of values for cardiac output, stroke volume, and systemic vascular resistance indices are presented. Interobserver reliability for Ultrasonic Cardiac Output Monitor was superior to that for standard blood pressure and heart rate measurement. This large study presents normal values for cardiovascular indices in children using the Ultrasonic Cardiac Output Monitor with good interobserver reliability.

  4. Lack of agreement and trending ability of the endotracheal cardiac output monitor compared with thermodilution

    DEFF Research Database (Denmark)

    Møller-Sørensen, H; Hansen, K L; Ostergaard, M

    2012-01-01

    BACKGROUND: Minimally invasive monitoring systems of central haemodynamics are gaining increasing popularity. The present study investigated the precision of the endotracheal cardiac output monitor (ECOM) system and its agreement with pulmonary artery catheter thermodilution (PAC TD) for measurin...

  5. Non-invasive cardiac output monitoring in neonates using bioreactance: a comparison with echocardiography.

    LENUS (Irish Health Repository)

    Weisz, Dany E

    2012-01-01

    Non-invasive cardiac output monitoring is a potentially useful clinical tool in the neonatal setting. Our aim was to evaluate a new method of non-invasive continuous cardiac output (CO) measurement (NICOM™) based on the principle of bioreactance in neonates.

  6. Haemodynamic changes during craniotomy monitored by a bioimpedance plethysmographic noninvasive cardiac output monitor.

    Science.gov (United States)

    Ali, Zulfiqar; Umamaheswara Rao, G S; Jaganath, A

    2009-06-01

    Profound cardiovascular changes may occur at various stages during a craniotomy. These changes require a detailed haemodynamic analysis including cardiac output. In the present study, we used a monitor based on electrical bioimpedance method for noninvasive cardiac output measurement. In 17 ASA I and II patients undergoing elective craniotomies for supratentorial tumours, the following haemodynamic parameters were measured noninvasively: heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP), stroke volume (SV), cardiac output (CO) and systemic vascular resistance (SVR). Haemodynamic changes in response to the following events were studied: (a) induction of anaesthesia with thiopentone, (b) 15 min of air-O(2)-isoflurane anaesthesia, (c) infiltration of the scalp with lidocaine adrenaline mixture, and (d) change of inspired gas mixture to N(2)O-O(2)-isoflurane. HR increased (P < 0.001) and SV decreased (P < 0.001) while CO remained unchanged, one min after administration of thiopentone. After 15 min of isoflurane anaesthesia, HR increased (P < 0.001) and, SBP (P = 0.02), DBP (P = 0.002) and SV (P = 0.003) decreased significantly without change in CO. Three minutes after infiltration of the scalp with lidocaine-adrenaline mixture, there was an increase in SBP (P = 0.001), DBP (P = 0.007), SV (P = 0.007) and CO (P = 0.001) and a decrease in SVR (P < 0.001). Addition of nitrous oxide (60%) to the inspired gas mixture decreased SBP (P = 0.003) and DBP (P = 0.001) with a trend for decrease in CO (P < 0.1). The changes recorded in the present study conform to those that have been documented earlier by using invasive monitoring. Bioimpedance plethysmography is a useful noninvasive technique for monitoring and detailed analysis of the rapidly changing systemic haemodynamics during a craniotomy. The device could be useful for investigating important haemodynamic changes in specific neurosurgical settings.

  7. Correlation Between the End-Tidal CO2 (EtCO2 and Decreased Cardiac Output Measured by Ultrasonic Cardiac Output Monitor (USCOM for Intubated Patients in ICU

    Directory of Open Access Journals (Sweden)

    Tjokorda Gde Agung Senopathi

    2017-01-01

    Full Text Available Background: assessment of cardiac output is crucial in management of critical ill patients. Various types of tool are available to measure cardiac output. However, most has limitations such as invasive, expensive, and require special skill. Assessment of End-tidal Carbon Dioxide (EtCO2 is expected to be used as an alternative estimation of cardiac output. It is based on the condition that when cardiac output is decreased, it decreased pulmonary blood flow and diffusion of CO2 into the alveolar, thereby increasing alveolar dead space and lowering EtCO2. Objective: to find a correlation between EtCO2 and decreased cardiac output measured by Ultrasonic Cardiac Output Monitor (USCOM for intubated patients in ICU of Sanglah General Hospital, Denpasar, Bali. Methods: This is a cross-sectional study, the correlation test conducted from June to August 2016 in ICU of Sanglah Hospital. The study involved 75 patients who eligible with a total population sampling technique. Intubated patients admitted to the ICU were evaluated for EtCO2 and USCOM in the first 24 hours by the researchers simultaneously. Shapiro-Francia test was used for normality and Pearson’s correlation tests was used to measure the correlations between variables. Results: The EtCO2 value obtained was positively correlated with cardiac output values (r = 0.373; p 0.001. Conclusion: there is a correlation between EtCO2 and decreased cardiac output measured by USCOM for intubated patients in ICU of Sanglah General Hospital, Denpasar

  8. Estimating changes in cardiac output using an implanted hemodynamic monitor in heart failure patients

    DEFF Research Database (Denmark)

    Ståhlberg, Marcus; Damgaard, Morten; Ersgård, David

    2010-01-01

    OBJECTIVES: The aim of this study was to evaluate an algorithm that estimates changes in cardiac output (CO) from right ventricular (RV) pressure waveforms derived from an implantable hemodynamic monitor (IHM) in heart failure patients. DESIGN: Twelve heart failure patients (NYHA II-III, EF 32...... was -0.39 L/min (11%). Limits of agreement were +/-1.56 L/min and relative error was 21%. CONCLUSIONS: A simple algorithm based on RV pressure wave form characteristics derived from an IHM can be used to estimate changes in CO in heart failure patients. These findings encourage further research aiming...

  9. A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis.

    Science.gov (United States)

    Vakily, A; Parsaei, H; Movahhedi, M M; Sahmeddini, M A

    2017-06-01

    Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Several methods have been developed for this purpose, but a majority of them are either invasive, too expensive or need special expertise and experience. Besides, they are not usually risk free and have consequences. Here, a semi-invasive system was designed and developed for continuous CO measurement via analyzing and processing arterial pulse waves. Quantitative evaluation of developed CO estimation system was performed using 7 signals. It showed that it has an acceptable average error of (6.5%) in estimating CO. In addition, this system has the ability to consistently estimate this parameter and to provide a CO versus time curve that assists in tracking changes of CO. Moreover, the system provides such curve for systolic blood pressure, diastolic blood pressure, average blood pressure, heart rate and stroke volume. Evaluation of the results showed that the developed system is capable of accurately estimating CO. The curves which the system provides for important parameters may be valuable in monitoring hemodynamic status of high-risk surgical patients and critically ill patients in Intensive Care Units (ICU). Therefore, it could be a suitable system for monitoring hemodynamic status of critically ill patients.

  10. Cardiac output measurement

    Directory of Open Access Journals (Sweden)

    Andreja Möller Petrun

    2014-02-01

    Full Text Available In recent years, developments in the measuring of cardiac output and other haemodynamic variables are focused on the so-called minimally invasive methods. The aim of these methods is to simplify the management of high-risk and haemodynamically unstable patients. Due to the need of invasive approach and the possibility of serious complications the use of pulmonary artery catheter has decreased. This article describes the methods for measuring cardiac output, which are based on volume measurement (Fick method, indicator dilution method, pulse wave analysis, Doppler effect, and electrical bioimpedance.

  11. Comparison of arterial pressure cardiac output monitoring with transpulmonary thermodilution in septic patients.

    Science.gov (United States)

    Böettger, Simon F; Pavlovic, Dragan; Gründling, Matthias; Wendt, Michael; Hung, Orlando; Henzler, Dietrich; Kern, Hartmut Richard; Lehmann, Christian

    2010-03-01

    The measurement of cardiac output in critically ill patients is complicated by rapid pathophysiological changes. The aim of this study was to compare the recently developed Arterial Pressure Cardiac Output algorithm (APCO) with transpulmonary thermodilution (TDCO). Clinical and hemodynamic parameters were tested for their impact on the measurements. Twenty septic patients were examined. Cardiac output measurements were performed simultaneously on 3 consecutive days. The data were evaluated using regression analysis and the Bland Altman approach. Bland Altman analysis presented a bias of 0.72 L/min and limits of agreement of 2.16 to 3.61 L/min for TDCO vs. APCO. Statistically significant covariables in the regression analysis were systemic vascular resistance (pmeasurements with a minimally invasive approach and simple access to the patient's hemodynamic state. However, an underestimation at high cardiac output and an overestimation at low cardiac output relative to transpulmonary thermodilution were observed in septic patients. Therefore, the APCO algorithm in its current state cannot be substituted for transpulmonary thermodilution.

  12. A-V Delay Versus Cardiac Output Measured with Thorax Bioimpedance Monitor

    Czech Academy of Sciences Publication Activity Database

    Vondra, Vlastimil; Halámek, Josef; Viščor, Ivo; Jurák, Pavel; Novák, M.; Lipoldová, J.

    2008-01-01

    Roč. 6, č. 1 (2008), s. 73 ISSN 1556-7451. [World Congress on Heart Disease /14./. 26.07.2008-29.07.2008, Toronto] Institutional research plan: CEZ:AV0Z20650511 Keywords : atrio -ventricular delay * resynchronization therapy * impedance cardiography * cardiac output Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery

  13. Cardiac output during exercise

    DEFF Research Database (Denmark)

    Siebenmann, C; Rasmussen, P.; Sørensen, H.

    2015-01-01

    Several techniques assessing cardiac output (Q) during exercise are available. The extent to which the measurements obtained from each respective technique compares to one another, however, is unclear. We quantified Q simultaneously using four methods: the Fick method with blood obtained from...... the right atrium (Q(Fick-M)), Innocor (inert gas rebreathing; Q(Inn)), Physioflow (impedance cardiography; Q(Phys)), and Nexfin (pulse contour analysis; Q(Pulse)) in 12 male subjects during incremental cycling exercise to exhaustion in normoxia and hypoxia (FiO2  = 12%). While all four methods reported...... a progressive increase in Q with exercise intensity, the slopes of the Q/oxygen uptake (VO2) relationship differed by up to 50% between methods in both normoxia [4.9 ± 0.3, 3.9 ± 0.2, 6.0 ± 0.4, 4.8 ± 0.2 L/min per L/min (mean ± SE) for Q(Fick-M), Q(Inn), QP hys and Q(Pulse), respectively; P = 0...

  14. Monitoring cardiac output during hyperbaric oxygen treatment of haemodynamically unstable patients

    DEFF Research Database (Denmark)

    Hansen, Marco Bo; Treschow, Frederik; Skielboe, Martin

    2013-01-01

    Patients suffering from necrotizing fasciitis (NF) are often haemodynamically unstable and require extended monitoring of cardiovascular parameters; yet this is limited during hyperbaric oxygen treatment (HBOT). We aimed to evaluate the use and safety of transoesophageal Doppler (TED) monitoring...

  15. Measuring Cardiac Output during Cardiopulmonary Exercise Testing.

    Science.gov (United States)

    Vignati, Carlo; Cattadori, Gaia

    2017-07-01

    Cardiac output is a key parameter in the assessment of cardiac function, and its measurement is fundamental to the diagnosis, treatment, and prognostic evaluation of all heart diseases. Until recently, cardiac output determination during exercise had been only possible through invasive methods, which were not practical in the clinical setting. Because [Formula: see text]o 2 is cardiac output times arteriovenous content difference, evaluation of cardiac output is usually included in its measurement. Because of the difficulty of directly measuring peak exercise cardiac output, indirect surrogate parameters have been proposed, but with only modest clinical usefulness. Direct measurement of cardiac output can now be made by several noninvasive techniques, such as rebreathing inert gases, impedance cardiology, thoracic bioreactance, estimated continuous cardiac output technology, and transthoracic echocardiography coupled to cardiopulmonary exercise testing, which allow more definitive results and better understanding of the underlying physiopathology.

  16. [Effects of application of pulse contour cardiac output monitoring technology in early treatment of patients with large area burns].

    Science.gov (United States)

    Wang, D Y; Xie, W G; Xi, M M; Li, Z; Wang, B

    2018-01-20

    Objective: To analyze the changes and relationship of early hemodynamic indexes of patients with large area burns monitored by pulse contour cardiac output (PiCCO) monitoring technology, so as to assess the guiding value of this technology in the treatment of patients with large area burns during shock period. Methods: Eighteen patients with large area burns, confirming to the study criteria, were admitted to our unit from May 2016 to May 2017. Pulse contour cardiac output index (PCCI), systemic vascular resistance index (SVRI), global end-diastolic volume index (GEDVI), and extravascular lung water index (EVLWI) of patients were monitored by PiCCO instrument from admission to post injury day (PID) 7, and they were calibrated and recorded once every four hours. The fluid infusion coefficients of patients at the first and second 24 hours post injury were calculated. The blood lactic acid values of patients from PID 1 to 7 were also recorded. The correlations among PCCI, SVRI, and GEDVI as well as the correlation between SVRI and blood lactic acid of these 18 patients were analyzed. Prognosis of patients were recorded. Data were processed with one-way analysis of variance, single sample t test and Bonferroni correction, Pearson correlation analysis, and Spearman rank correlation analysis. Results: (1) There was statistically significant difference in PCCI value of patients from post injury hour (PIH) 4 to 168 ( F =7.428, P 0.05). (2) There was statistically significant difference in SVRI value of patients from PIH 4 to 168 ( F =7.863, P 0.05). (3) There was no statistically significant difference in the GEDVI values of patients from PIH 4 to 168 ( F =0.704, P >0.05). The GEDVI values of patients at PIH 8, 12, 16, 20, and 24 were significantly lower than normal value ( t =-3.112, -3.554, -2.969, -2.450, -2.476, P 0.05). (4) There was statistically significant difference in EVLWI value of patients from PIH 4 to 168 ( F =1.859, P 0.05). (5) The fluid infusion

  17. Multisite Tissue Oxygenation Monitoring Indicates Organ-Specific Flow Distribution and Oxygen Delivery Related to Low Cardiac Output in Preterm Infants With Clinical Sepsis

    NARCIS (Netherlands)

    van der Laan, Michelle E.; Roofthooft, Marcus T. R.; Fries, Marian W. A.; Schat, Trijntje E.; Bos, Arend F.; Berger, Rolf M. F.; Kooi, Elisabeth M. W.

    Objectives: Cardiac output may be compromised in preterm infants with sepsis. Whether low cardiac output is associated with low tissue oxygen supply in these patients is unclear. The aim of the current study was to assess the association between cardiac output, assessed by echocardiography, and

  18. A prospective comparison of a noninvasive cardiac output monitor versus esophageal Doppler monitor for goal-directed fluid therapy in colorectal surgery patients.

    Science.gov (United States)

    Waldron, Nathan H; Miller, Timothy E; Thacker, Julie K; Manchester, Amy K; White, William D; Nardiello, John; Elgasim, Magdi A; Moon, Richard E; Gan, Tong J

    2014-05-01

    Goal-directed fluid therapy (GDFT) is associated with improved outcomes after surgery. The esophageal Doppler monitor (EDM) is widely used, but has several limitations. The NICOM, a completely noninvasive cardiac output monitor (Cheetah Medical), may be appropriate for guiding GDFT. No prospective studies have compared the NICOM and the EDM. We hypothesized that the NICOM is not significantly different from the EDM for monitoring during GDFT. One hundred adult patients undergoing elective colorectal surgery participated in this study. Patients in phase I (n = 50) had intraoperative GDFT guided by the EDM while the NICOM was connected, and patients in phase II (n = 50) had intraoperative GDFT guided by the NICOM while the EDM was connected. Each patient's stroke volume was optimized using 250-mL colloid boluses. Agreement between the monitors was assessed, and patient outcomes (postoperative pain, nausea, and return of bowel function), complications (renal, pulmonary, infectious, and wound complications), and length of hospital stay (LOS) were compared. Using a 10% increase in stroke volume after fluid challenge, agreement between monitors was 60% at 5 minutes, 61% at 10 minutes, and 66% at 15 minutes, with no significant systematic disagreement (McNemar P > 0.05) at any time point. The EDM had significantly more missing data than the NICOM. No clinically significant differences were found in total LOS or other outcomes. The mean LOS was 6.56 ± 4.32 days in phase I and 6.07 ± 2.85 days in phase II, and 95% confidence limits for the difference were -0.96 to +1.95 days (P = 0.5016). The NICOM performs similarly to the EDM in guiding GDFT, with no clinically significant differences in outcomes, and offers increased ease of use as well as fewer missing data points. The NICOM may be a viable alternative monitor to guide GDFT.

  19. Methods and apparatus for determining cardiac output

    Science.gov (United States)

    Cohen, Richard J. (Inventor); Mukkamala, Ramakrishna (Inventor); Sherman, Derin A. (Inventor)

    2010-01-01

    The present invention provides methods and apparatus for determining a dynamical property of the systemic or pulmonary arterial tree using long time scale information, i.e., information obtained from measurements over time scales greater than a single cardiac cycle. In one aspect, the invention provides a method and apparatus for monitoring cardiac output (CO) from a single blood pressure signal measurement obtained at any site in the systemic or pulmonary arterial tree or from any related measurement including, for example, fingertip photoplethysmography.According to the method the time constant of the arterial tree, defined to be the product of the total peripheral resistance (TPR) and the nearly constant arterial compliance, is determined by analyzing the long time scale variations (greater than a single cardiac cycle) in any of these blood pressure signals. Then, according to Ohm's law, a value proportional to CO may be determined from the ratio of the blood pressure signal to the estimated time constant. The proportional CO values derived from this method may be calibrated to absolute CO, if desired, with a single, absolute measure of CO (e.g., thermodilution). The present invention may be applied to invasive radial arterial blood pressure or pulmonary arterial blood pressure signals which are routinely measured in intensive care units and surgical suites or to noninvasively measured peripheral arterial blood pressure signals or related noninvasively measured signals in order to facilitate the clinical monitoring of CO as well as TPR.

  20. Cardiac event monitors

    Science.gov (United States)

    ... ECG) - ambulatory; Continuous electrocardiograms (EKGs); Holter monitors; Transtelephonic event monitors ... attached. You can carry or wear a cardiac event monitor up to 30 days. You carry the ...

  1. Noninvasive cardiac output monitoring during exercise testing: Nexfin pulse contour analysis compared to an inert gas rebreathing method and respired gas analysis.

    Science.gov (United States)

    Bartels, Sebastiaan A; Stok, Wim J; Bezemer, Rick; Boksem, Remco J; van Goudoever, Jeroen; Cherpanath, Thomas G V; van Lieshout, Johannes J; Westerhof, Berend E; Karemaker, John M; Ince, Can

    2011-10-01

    Exercise testing is often used to assess cardiac function during physical exertion to obtain diagnostic information. However, this procedure is limited to measuring the electrical activity of the heart using electrocardiography and intermittent blood pressure (BP) measurements and does not involve the continuous assessment of heart functioning. In this study, we compared continuous beat-to-beat pulse contour analysis to monitor noninvasive cardiac output (CO) during exercise with inert gas rebreathing and respired gas analysis. Nineteen healthy male volunteers were subjected to bicycle ergometry testing with increasing workloads. Cardiac output was deter- mined noninvasively by continuous beat-to-beat pulse contour analysis (Nexfin) and by inert gas rebreathing, and estimated using the respired gas analysis method. The effects of the rebreathing maneuver on heart rate (HR), stroke volume (SV), and CO were evaluated. The CO values derived from the Nexfin- and inert gas rebreathing methods were well correlated (r = 0.88, P measurement bias of 0.4 ± 1.8 L/min. Nexfin- and respired gas analysis-derived CO values correlated even better (r = 0.94, P measurement bias of -0.70 ± 1.6 L/min. At rest, the rebreathing maneuver increased HR by 13 beats/min (P parameters during exercise. Nexfin continuous beat-to-beat pulse contour analysis is an appropriate method for noninvasive assessment of CO during exercise.

  2. Comparing Methods for Cardiac Output

    DEFF Research Database (Denmark)

    Graeser, Karin; Zemtsovski, Mikhail; Kofoed, Klaus F

    2018-01-01

    tomography (CT) angiography. Sixty-two patients, scheduled for elective heart surgery, were included; 1 was subsequently excluded for logistic reasons. Inclusion criteria were coronary artery bypass surgery (N = 42) and aortic valve replacement (N = 19). Exclusion criteria were chronic atrial fibrillation...... of the left ventricular outflow tract. METHODS: The primary aim was a systematic comparison of CO with Doppler-derived 3D TEE and CO by thermodilution in a broad population of patients undergoing cardiac surgery. A subanalysis was performed comparing cross-sectional area by TEE with cardiac computed......, left ventricular ejection fraction below 0.40 and intracardiac shunts. Nineteen randomly selected patients had a cardiac CT the day before surgery. All images were stored for blinded post hoc analyses, and Bland-Altman plots were used to assess agreement between measurement methods, defined as the bias...

  3. Monitoring of cardiac output and lung ventilation by Electrical Impedance Tomography in a porcine model of acute lung injury.

    Science.gov (United States)

    Hochhausen, Nadine; Dohmeier, Henriette; Rossaint, Rolf; Czaplik, Michael

    2017-07-01

    Adequate medical treatment of the Acute Respiratory Distress Syndrome is still challenging since patient-individual aspects have to be taken into account. Lung protective ventilation and hemodynamic stability have always been two of the most crucial aims of intensive care therapy. For both aspects, a continuous - preferably non-invasive - monitoring is desirable that is available at the bedside. Unfortunately, there is no technique clinically established yet, that provides both measurement of cardiac stroke volume and ventilation dynamics in real-time. Electrical Impedance Tomography (EIT) is a promising technique to close this gap. The aim of the study was to investigate if stroke volume can be estimated by a self-developed software using EIT-based image analysis. In addition, two EIT-derived parameters, namely Global Inhomogeneity Index (GII) and Impedance Ratio (IR), were calculated to evaluate homogeneity of air distribution. Experimental acute lung injury (ALI) was provoked in seven female pigs (German Landrace) by lipopolysaccharide (LPS). All animals suffered from experimental ALI 3 to 4 hours after LPS infusion. At defined time points, respiratory and hemodynamic parameters, blood gas analyses and EIT-recordings were performed. Eight hours after ALI, animals were euthanized. Stroke volume, derived from pulmonary artery catheter (PAC), decreased continuously up to four hours after ALI. Then, stroke volume increased slightly. Stroke volume, derived from the self-developed tool, showed the same characteristics (p=0.047, r = 0.365). In addition to the GII and IR individually, both classified scores showed a high correlation with the Horowitz Index, defined as p a O 2 /FiO 2 . To conclude, EIT-derived measures enabled a reliable estimation of cardiac stroke volume and regional distribution of ventilation.

  4. Accuracy and precision of the ultrasound cardiac output monitor (USCOM 1A) in pregnancy: comparison with three-dimensional transthoracic echocardiography.

    Science.gov (United States)

    McNamara, H; Barclay, P; Sharma, V

    2014-10-01

    Cardiac output (CO) monitoring is helpful in the assessment of critically ill pregnant women, but invasive monitors are often unsuitable for use. We aimed to measure agreement between the non-invasive ultrasound cardiac output monitor (USCOM) and three-dimensional transthoracic echocardiography (3D-TTE) in pregnant women. Healthy pregnant women from 25 weeks gestation onwards participated. In the left lateral position at rest, CO was measured with the USCOM and 3D-TTE. A single operator performed all USCOM measurements, with a different operator performing all echocardiography. Both were blinded to results from the other device. Each USCOM trace was analysed using two modes: flowtrace (FT) and touchpoint (TP). A second, blinded USCOM reading was taken to assess reproducibility. USCOM readings were obtained in 92, and 3D-TTE images in 85 participants. The mean CO was 5.7, 7.7, and 6.2 litre min(-1) measured by 3D-TTE, USCOM FT, and USCOM TP, respectively. USCOM bias was +2.0 litre min(-1) (FT) and +0.4 litre min(-1) (TP). Limits of agreement were -0.2 to +4.2 litre min(-1) (FT) and -1.4 to +2.3 litre min(-1) (TP). The mean percentage difference was 32.6% (FT) and 31.4% (TP) for CO and 27.0% (FT) and 27.5% (TP) for stroke volume. Intraclass correlation between repeated USCOM readings was 0.9 (FT) and 0.86 (TP). USCOM has acceptable agreement with 3D-TTE for the measurement of CO in pregnancy. The positive bias of the USCOM, particularly in the FT mode, may be due to the hyperdynamic cardiovascular state in pregnancy. We suggest using the TP mode in this patient population. © The Author 2014. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Cardiac output measurement instruments controlled by microprocessors

    International Nuclear Information System (INIS)

    Spector, M.; Barritault, L.; Boeri, C.; Fauchet, M.; Gambini, D.; Vernejoul, P. de

    The nuclear medicine and biophysics laboratory of the Necker-Enfants malades University Hospital Centre has built a microprocessor controlled Cardiac flowmetre. The principle of the cardiac output measurement from a radiocardiogram is well established. After injection of a radioactive indicator upstream from the heart cavities the dilution curve is obtained by the use of a gamma-ray precordial detector. This curve normally displays two peaks due to passage of the indicator into the right and left sides of the heart respectively. The output is then obtained from the stewart Hamilton principle once recirculation is eliminated. The graphic method used for the calculation however is long and tedious. The decreasing fraction of the dilution curve is projected in logarithmic space in order to eliminate recirculation by determining the mean straight line from which the decreasing exponential is obtained. The principle of the use of microprocessors is explained (electronics, logics) [fr

  6. Comparison of cardiac output measurement techniques

    DEFF Research Database (Denmark)

    Espersen, K; Jensen, E W; Rosenborg, D

    1995-01-01

    and CR, respectively, and TD were 2.5 +/- 2.2 and 2.6 +/- 1.6 l/min. The overall agreement between DOP and CR was 0.1 +/- 1.6 l/min. In conclusion, TD overestimated cardiac output compared to the other techniques and the poor agreement has to be taken into consideration especially in measures of low...

  7. Videodensitometric Methods for Cardiac Output Measurements

    Science.gov (United States)

    Mischi, Massimo; Kalker, Ton; Korsten, Erik

    2003-12-01

    Cardiac output is often measured by indicator dilution techniques, usually based on dye or cold saline injections. Developments of more stable ultrasound contrast agents (UCA) are leading to new noninvasive indicator dilution methods. However, several problems concerning the interpretation of dilution curves as detected by ultrasound transducers have arisen. This paper presents a method for blood flow measurements based on UCA dilution. Dilution curves are determined by real-time densitometric analysis of the video output of an ultrasound scanner and are automatically fitted by the Local Density Random Walk model. A new fitting algorithm based on multiple linear regression is developed. Calibration, that is, the relation between videodensity and UCA concentration, is modelled by in vitro experimentation. The flow measurement system is validated by in vitro perfusion of SonoVue contrast agent. The results show an accurate dilution curve fit and flow estimation with determination coefficient larger than 0.95 and 0.99, respectively.

  8. Videodensitometric Methods for Cardiac Output Measurements

    Directory of Open Access Journals (Sweden)

    Massimo Mischi

    2003-04-01

    Full Text Available Cardiac output is often measured by indicator dilution techniques, usually based on dye or cold saline injections. Developments of more stable ultrasound contrast agents (UCA are leading to new noninvasive indicator dilution methods. However, several problems concerning the interpretation of dilution curves as detected by ultrasound transducers have arisen. This paper presents a method for blood flow measurements based on UCA dilution. Dilution curves are determined by real-time densitometric analysis of the video output of an ultrasound scanner and are automatically fitted by the Local Density Random Walk model. A new fitting algorithm based on multiple linear regression is developed. Calibration, that is, the relation between videodensity and UCA concentration, is modelled by in vitro experimentation. The flow measurement system is validated by in vitro perfusion of SonoVue contrast agent. The results show an accurate dilution curve fit and flow estimation with determination coefficient larger than 0.95 and 0.99, respectively.

  9. Comparison of cardiac output measurement techniques

    DEFF Research Database (Denmark)

    Espersen, K; Jensen, E W; Rosenborg, D

    1995-01-01

    at a workload of 50 W (EX). The agreements between the techniques, two by two, were expressed as the bias calculated as the averaged differences between the techniques. Precision was expressed as the standard deviation of the bias. The overall agreement (bias +/- precision) between TD, DOP and CR respectively...... and CR, respectively, and TD were 2.5 +/- 2.2 and 2.6 +/- 1.6 l/min. The overall agreement between DOP and CR was 0.1 +/- 1.6 l/min. In conclusion, TD overestimated cardiac output compared to the other techniques and the poor agreement has to be taken into consideration especially in measures of low...

  10. Use of a Minimally Invasive Cardiac Output Monitor to Optimise Haemodynamics in a Patient with Mitral Valve Disease Undergoing Cerebrovascular Surgery

    Directory of Open Access Journals (Sweden)

    Ali M. Al-Mashani

    2017-08-01

    Full Text Available Patients with mitral valve disease undergoing cerebrovascular surgery face increased inherent risks due to their associated cardiac comorbidities. As such, the anaesthetic management of such patients is distinctly challenging. Simultaneous consideration of both the cerebrovascular and underlying cardiac conditions determines key anaesthetic issues, as fluids and vasopressors or inotropes need to be titrated according to haemodynamic variables in order to optimise cerebral blood flow without compromising cardiac function. We report a 45-yearold female patient with mild mitral stenosis and moderate-to-severe mitral regurgitation who presented to the Khoula Hospital, Muscat, Oman, in 2016 following a ruptured anterior communicating artery aneurysm requiring urgent surgical intervention. As highlighted in this case, the VolumeView EV1000™ (Edwards Lifesciences, Irvine, California, USA system is a minimially invasive haemodynamic monitor that can help immensely in the perioperative management of such patients.

  11. Peripheral vasodilatation determines cardiac output in exercising humans

    DEFF Research Database (Denmark)

    Bada, A A; Svendsen, J H; Secher, N H

    2012-01-01

    In dogs, manipulation of heart rate has no effect on the exercise-induced increase in cardiac output. Whether these findings apply to humans remain uncertain, because of the large differences in cardiovascular anatomy and regulation. To investigate the role of heart rate and peripheral vasodilata...... demonstrate that the elevated cardiac output during steady-state exercise is regulated by the increase in skeletal muscle blood flow and venous return to the heart, whereas the increase in heart rate appears to be secondary to the regulation of cardiac output....... arterial ATP infusion at rest. Exercise and ATP infusion increased cardiac output, leg blood flow and vascular conductance (P ... vasodilatation in the regulation of cardiac output during steady-state exercise, we measured central and peripheral haemodynamics in 10 healthy male subjects, with and without atrial pacing (100–150 beats min(−1)) during: (i) resting conditions, (ii) one-legged knee extensor exercise (24 W) and (iii) femoral...

  12. Cardiac Output Calculation and Three-Dimensional Echocardiography

    NARCIS (Netherlands)

    Montealegre-Gallegos, Mario; Mahmood, Feroze; Owais, Khurram; Hess, Phillip; Jainandunsing, Jayant S.; Matyal, Robina

    Objective: To compare the determination of stroke volume (SV) and cardiac output (CO) using 2-dimensional (2D) versus 3-dimensional (3D) transesophageal echocardiography (TEE). Design: Prospective observational study. Setting: Tertiary care university hospital. Participants: 35 patients without

  13. Predictors of low cardiac output in decompensated severe heart failure

    Directory of Open Access Journals (Sweden)

    Marcelo Eidi Ochiai

    2011-01-01

    Full Text Available OBJECTIVE: To identify predictors of low cardiac output and mortality in decompensated heart failure. INTRODUCTION: Introduction: Patients with decompensated heart failure have a high mortality rate, especially those patients with low cardiac output. However, this clinical presentation is uncommon, and its management is controversial. METHODS: We studied a cohort of 452 patients hospitalized with decompensated heart failure with an ejection fraction of 60 years, and 64.6% were men. Low cardiac output was present in 281 (63% patients on admission. Chagas disease was the cause of heart failure in 92 (20.4% patients who had higher B type natriuretic peptide levels (1,978.38 vs. 1,697.64 pg/mL; P = 0.015. Predictors of low cardiac output were Chagas disease (RR: 3.655, P<0.001, lower ejection fraction (RR: 2.414, P<0.001, hyponatremia (RR: 1.618, P = 0.036, and renal dysfunction (RR: 1.916, P = 0.007. Elderly patients were inversely associated with low cardiac output (RR: 0.436, P = 0.001. Predictors of mortality were Chagas disease (RR: 2.286, P<0.001, ischemic etiology (RR: 1.449, P = 0.035, and low cardiac output (RR: 1.419, P = 0.047. CONCLUSIONS: In severe decompensated heart failure, predictors of low cardiac output are Chagas disease, lower ejection fraction, hyponatremia, and renal dysfunction. Additionally, Chagas disease patients have higher B type natriuretic peptide levels and a worse prognosis independent of lower ejection fraction.

  14. Validation of noninvasive pulse contour cardiac output using finger arterial pressure in cardiac surgery patients requiring fluid therapy

    NARCIS (Netherlands)

    Hofhuizen, Charlotte; Lansdorp, Benno; van der Hoeven, Johannes G.; Scheffer, Gert-Jan; Lemson, Joris

    2014-01-01

    Introduction Nexfin (Edwards Lifesciences, Irvine, CA) allows for noninvasive continuous monitoring of blood pressure (ABPNI) and cardiac output (CONI) by measuring finger arterial pressure (FAP). To evaluate the accuracy of FAP in measuring ABPNI and CONI as well as the adequacy of detecting

  15. Validation of noninvasive pulse contour cardiac output using finger arterial pressure in cardiac surgery patients requiring fluid therapy

    NARCIS (Netherlands)

    Hofhuizen, C.M.; Lansdorp, B.; Hoeven, J.G. van der; Scheffer, G.J.; Lemson, J.

    2014-01-01

    INTRODUCTION: Nexfin (Edwards Lifesciences, Irvine, CA) allows for noninvasive continuous monitoring of blood pressure (ABPNI) and cardiac output (CONI) by measuring finger arterial pressure (FAP). To evaluate the accuracy of FAP in measuring ABPNI and CONI as well as the adequacy of detecting

  16. Cardiac output and blood volume parameters using femoral arterial thermodilution.

    Science.gov (United States)

    López-Herce, Jesús; Bustinza, Amaya; Sancho, Luis; Mencía, Santiago; Carrillo, Angel; Moral, Ramón; Bellón, Jose María

    2009-02-01

    The pulse-induced continuous cardiac output (PiCCO) system is a less invasive method than pulmonary thermodilution for the measurement of cardiac output and estimating blood volume parameters. The normal values in children have not been defined. The purpose of the present paper was therefore to evaluate cardiac output and parameters of blood volume using femoral arterial thermodilution in critically ill children. A prospective study was performed in 17 critically ill children aged between 2 months and 14 years. Two measurements were taken for each determination of cardiac output, global end diastolic volume (GEDVI), intrathoracic blood volume index (ITBI), extravascular lung water index (ELWI), systolic volume index (SVI), stroke volume variation (SVV), cardiac function index (CFI), left ventricular contractility (dp/dt max), and the systemic vascular resistance index (SVRI). One hundred and seventeen measurements were performed. The mean cardiac index (CI) was 3.5 +/- 1.3 L/min per m(2). The GEDVI (399.7 +/- 349.1 mL/m(2)), ITBI (574.5 +/- 212.2 mL/m(2)) and dp/dt max (804.6 +/- 372.1 mmHg/s) were lower than reported in adults, whereas ELWI (18.9 +/- 9.3 mL/m2) and CFI (8 +/- 2.5 L/min) where higher. The GEDVI, SVI, dp/dt max and CI increased with the weight of the patients whereas the ELWI values decreased. Femoral arterial thermodilution is a suitable technique for the measurement of cardiac output in critically ill children. The intrathoracic and intracardiac volumes are lower than in adults, whereas extrapulmonary water is higher; these values are related to the weight of the patient.

  17. Cardiac output and vasodilation in the vasovagal response

    DEFF Research Database (Denmark)

    Wieling, Wouter; Jardine, David L.; de Lange, Frederik J

    2016-01-01

    The simple faint is secondary to hypotension and bradycardia resulting in transient loss of consciousness. According to Ohm's law applied to the circulation, BP = SVR × CO, hypotension can result from a decrease in systemic vascular resistance (SVR), cardiac output (CO), or both. It is important...

  18. Noninvasive cardiac output determination using applanation tonometry-derived radial artery pulse contour analysis in critically ill patients

    DEFF Research Database (Denmark)

    Compton, Friederike; Wittrock, Marc; Schaefer, Juergen-Heiner

    2008-01-01

    Conventional thermodilution cardiac output (CO) monitoring is limited mainly to intensive care units and operating rooms because it requires the use of invasive techniques. To reduce the potential for complications and to broaden the applicability of hemodynamic monitoring, noninvasive methods fo...

  19. Noninvasive cardiac output measurement using bioreactance in postoperative pediatric patients.

    Science.gov (United States)

    Vergnaud, Estelle; Vidal, Charles; Verchere, Juliette Montmayeur; Taright, Hanna; Meyer, Philippe G; Carli, Pierre A; Orliaguet, Gilles A

    2015-02-01

    Thoracic bioreactance is a noninvasive and continuous method of cardiac output (CO) measurement that is being developed in adult patients. Very little information is available on thoracic bioreactance use in children. The aim of the study was to evaluate the ability of a bioreactance device (NICOM(®) ; Cheetah Medical, Tel Aviv, Israel) to estimate CO and to track changes in CO induced by volume expansion (VE) in children. Cardiac output values obtained using the NICOM(®) device (CONICOM ) and measured by trans-thoracic echocardiography (COTTE ) were compared in pediatric neurosurgical patients during the postoperative period. Seventy-three pairs of measurements of CO obtained in 30 children were available for analysis. The bias (lower and upper limits of agreement) between CONICOM and COTTE was -0.11 (-1.4 to 1.2) l·min(-1). The percentage error (PE) was 55%. The precision of the NICOM(®) device was 45%. A significant correlation was observed between the CO values obtained using the two methods (r = 0.89, icom induced by VE was 84% following exclusion of patients with changes in CO <15% (n = 5). The PE observed is too large, and the limits of agreement too wide, to enable us to comment on the equivalence of the two techniques of CO measurements. However, the NICOM(®) device performs well in tracking changes in CO following VE. © 2014 John Wiley & Sons Ltd.

  20. Systematic review of cardiac output measurements by echocardiography vs. thermodilution

    DEFF Research Database (Denmark)

    Wetterslev, Mik; Møller-Sørensen, Hasse; Johansen, Rasmus Rothmann

    2016-01-01

    PURPOSE: Echocardiography is frequently used in the hemodynamic evaluation of critically ill patients, but inaccurate measurements may lead to wrong clinical decisions. The aim of our systematic review was to investigate the interchangeability of echocardiography with thermodilution technique...... of the studies assessed left-sided heart structures and the majority had small bias, wide limits of agreement, and high percentage error between echocardiography and thermodilution. In only two of the 24 studies the precision of each technique (echocardiography and thermodilution) was assessed before comparing...... them. In the single study evaluating trending ability using valid methodology, agreement was observed between echocardiography and thermodilution in detecting the directional changes in cardiac output, but the magnitude of changes varied considerably. CONCLUSIONS: The majority of studies comparing...

  1. Cardiac output estimation using pulmonary mechanics in mechanically ventilated patients.

    Science.gov (United States)

    Sundaresan, Ashwath; Chase, J Geoffrey; Hann, Christopher E; Shaw, Geoffrey M

    2010-11-25

    The application of positive end expiratory pressure (PEEP) in mechanically ventilated (MV) patients with acute respiratory distress syndrome (ARDS) decreases cardiac output (CO). Accurate measurement of CO is highly invasive and is not ideal for all MV critically ill patients. However, the link between the PEEP used in MV, and CO provides an opportunity to assess CO via MV therapy and other existing measurements, creating a CO measure without further invasiveness.This paper examines combining models of diffusion resistance and lung mechanics, to help predict CO changes due to PEEP. The CO estimator uses an initial measurement of pulmonary shunt, and estimations of shunt changes due to PEEP to predict CO at different levels of PEEP. Inputs to the cardiac model are the PV loops from the ventilator, as well as the oxygen saturation values using known respiratory inspired oxygen content. The outputs are estimates of pulmonary shunt and CO changes due to changes in applied PEEP. Data from two published studies are used to assess and initially validate this model.The model shows the effect on oxygenation due to decreased CO and decreased shunt, resulting from increased PEEP. It concludes that there is a trade off on oxygenation parameters. More clinically importantly, the model also examines how the rate of CO drop with increased PEEP can be used as a method to determine optimal PEEP, which may be used to optimise MV therapy with respect to the gas exchange achieved, as well as accounting for the impact on the cardiovascular system and its management.

  2. Cardiac output estimation using pulmonary mechanics in mechanically ventilated patients

    Directory of Open Access Journals (Sweden)

    Hann Christopher E

    2010-11-01

    Full Text Available Abstract The application of positive end expiratory pressure (PEEP in mechanically ventilated (MV patients with acute respiratory distress syndrome (ARDS decreases cardiac output (CO. Accurate measurement of CO is highly invasive and is not ideal for all MV critically ill patients. However, the link between the PEEP used in MV, and CO provides an opportunity to assess CO via MV therapy and other existing measurements, creating a CO measure without further invasiveness. This paper examines combining models of diffusion resistance and lung mechanics, to help predict CO changes due to PEEP. The CO estimator uses an initial measurement of pulmonary shunt, and estimations of shunt changes due to PEEP to predict CO at different levels of PEEP. Inputs to the cardiac model are the PV loops from the ventilator, as well as the oxygen saturation values using known respiratory inspired oxygen content. The outputs are estimates of pulmonary shunt and CO changes due to changes in applied PEEP. Data from two published studies are used to assess and initially validate this model. The model shows the effect on oxygenation due to decreased CO and decreased shunt, resulting from increased PEEP. It concludes that there is a trade off on oxygenation parameters. More clinically importantly, the model also examines how the rate of CO drop with increased PEEP can be used as a method to determine optimal PEEP, which may be used to optimise MV therapy with respect to the gas exchange achieved, as well as accounting for the impact on the cardiovascular system and its management.

  3. Estimated venous return surface and cardiac output curve precisely predicts new hemodynamics after volume change.

    Science.gov (United States)

    Sugimachi, Masaru; Sunagawa, Kenji; Uemura, Kazunori; Kamiya, Atsunori; Shimizu, Shuji; Inagaki, Masashi; Shishido, Toshiaki

    2010-01-01

    In our extended Guyton's model, the ability of heart to pump blood is characterized by a cardiac output curve and the ability of vasculature to pool blood by a venous return surface. These intersect in a three-dimensional coordinate system at the operating right atrial pressure, left atrial pressure, and cardiac output. The baseline cardiac output curve and venous return surface and their changes after volume change would predict new hemodynamics. The invasive methods needed to precisely characterize cardiac output curve and venous return surface led us to aim at estimating cardiac output curve and venous return surface from a single hemodynamic measurement. Using the average values for two logarithmic function parameters, and for two slopes of a surface, we were able to estimate cardiac output curve and venous return surface. The estimated curve and surface predicted new hemodynamics after volume change precisely.

  4. Central venous oxygen saturation for the diagnosis of low cardiac output in septic shock patients

    DEFF Research Database (Denmark)

    Perner, A; Haase, N; Wiis, J

    2010-01-01

    Simple diagnostic tests are needed to screen septic patients for low cardiac output because intervention is recommended in these patients. We assessed the diagnostic value of central venous oxygen saturation in the superior vena cava (ScvO(2)) for detecting low cardiac output in patients with sep...... with septic shock.......Simple diagnostic tests are needed to screen septic patients for low cardiac output because intervention is recommended in these patients. We assessed the diagnostic value of central venous oxygen saturation in the superior vena cava (ScvO(2)) for detecting low cardiac output in patients...

  5. Central venous oxygen saturation for the diagnosis of low cardiac output in septic shock patients

    DEFF Research Database (Denmark)

    Perner, A; Haase, N; Wiis, J

    2010-01-01

    Simple diagnostic tests are needed to screen septic patients for low cardiac output because intervention is recommended in these patients. We assessed the diagnostic value of central venous oxygen saturation in the superior vena cava (ScvO(2)) for detecting low cardiac output in patients with sep......Simple diagnostic tests are needed to screen septic patients for low cardiac output because intervention is recommended in these patients. We assessed the diagnostic value of central venous oxygen saturation in the superior vena cava (ScvO(2)) for detecting low cardiac output in patients...

  6. Multicenter study verifying a method of noninvasive continuous cardiac output measurement using pulse wave transit time: a comparison with intermittent bolus thermodilution cardiac output.

    Science.gov (United States)

    Yamada, Takashige; Tsutsui, Masato; Sugo, Yoshihiro; Sato, Tetsufumi; Akazawa, Toshimasa; Sato, Nobukazu; Yamashita, Koichi; Ishihara, Hironori; Takeda, Junzo

    2012-07-01

    Many technologies have been developed for minimally invasive monitoring of cardiac output. Estimated continuous cardiac output (esCCO) measurement using pulse wave transit time is one noninvasive method. Because it does not require any additional sensors other than those for conducting 3 basic forms of monitoring (electrocardiogram, pulse oximeter wave, and noninvasive (or invasive) arterial blood pressure measurement), esCCO measurement is potentially useful in routine clinical circulatory monitoring for any patient including low-risk patients. We evaluated the efficacy of noninvasive esCCO using pulse wave transit time in this multicenter study. We compared esCCO and intermittent bolus thermodilution cardiac output (TDCO) in 213 patients, 139 intensive care units (ICUs), and 74 operating rooms (ORs), at 7 participating institutions. We performed electrocardiogram, pulse oximetry, TDCO, and arterial blood pressure measurements in patients in ICUs and ORs; a single calibration was performed to measure esCCO continuously. TDCO measurement was performed once daily for ICU patients and every hour for OR patients, and just before the removal of the pulmonary arterial catheter from patients in both the ICU and OR. We evaluated esCCO against TDCO with correlation analysis and Bland and Altman analysis and also assessed the change of bias over time. Furthermore, we inspected the impact of change in systemic vascular resistance (SVR) on change in bias because abnormal SVR was assumed to be a factor contributing to the change of the bias. From among 588 esCCO and TDCO datasets (excluding calibration points), 587 datasets were analyzed for 213 patients. The analysis results show a correlation coefficient of 0.79 (P time intervals over 48 hours after calibration (repeated-measures analysis of variance P = 0.781) in the ICU. The influence of SVR on esCCO analysis showed a correlation coefficient between SVR and an error of 0.37 (P < 0.0001, 95% confidence interval 0

  7. Reference Values for Peak Exercise Cardiac Output in Healthy Individuals.

    Science.gov (United States)

    Agostoni, Piergiuseppe; Vignati, Carlo; Gentile, Piero; Boiti, Costanza; Farina, Stefania; Salvioni, Elisabetta; Mapelli, Massimo; Magrì, Damiano; Paolillo, Stefania; Corrieri, Nicoletta; Sinagra, Gianfranco; Cattadori, Gaia

    2017-06-01

    Cardiac output (Q˙) is a key parameter in the assessment of cardiac function, its measurement being crucial for the diagnosis, treatment, and prognostic evaluation of all heart diseases. Until recently, Q˙ determination at peak exercise has been possible through invasive methods, so that normal values were obtained in studies based on small populations. Nowadays, peak Q˙ can be measured noninvasively by means of the inert gas rebreathing (IGR) technique. The present study was undertaken to provide reference values for peak Q˙ in the normal general population and to obtain a formula able to estimate peak exercise Q˙ from measured peak oxygen uptake (V˙o 2 ). We studied 500 normal subjects (age, 44.9 ± 1.5 years; range, 18-77 years; 260 men, 240 women) who underwent a maximal cardiopulmonary exercise test with peak Q˙ measurement by IGR. In the overall study sample, peak Q˙ was 13.2 ± 3.5 L/min (men, 15.3 ± 3.3 L/min; women, 11.0 ± 2.0 L/min; P exercise was (4.4 × peak V˙o 2 ) + 4.3 in the overall study cohort, (4.3 × peak V˙o 2 ) + 4.5 in men, and (4.9 × peak V˙o 2 ) + 3.6 in women. The simultaneous measurement of Q˙ and V˙o 2 at peak exercise in a large sample of healthy subjects provided an equation to predict peak Q˙ from peak V˙o 2 values. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  8. Cardiac output determined by echocardiography in patients with cirrhosis: comparison with the indicator dilution technique

    DEFF Research Database (Denmark)

    Andersen, Ulrik B; Møller, Søren; Bendtsen, Flemming

    2003-01-01

    BACKGROUND/AIMS: Measurement of cardiac output in hyperkinetic patients with cirrhosis by Doppler echocardiography is increasingly reported, but has not been validated. We have compared simultaneous measurements of cardiac output by Doppler echocardiography (CO(d)) and by the indicator dilution...

  9. RESPIRATION AND MEASUREMENT OF CARDIAC-OUTPUT BY THERMODILUTION AND CENTRAL OR PERIPHERAL DYE DILUTION

    NARCIS (Netherlands)

    DELHAAS, T; MOOK, GA; ZIJLSTRA, WG; BERGSTRA, A; VANDENMOLEN, H; NIJMEIJER, A; Schut, J.K.

    Cardiac output as measured by indicator dilution methods during artificial ventilation shows differences up to +/-35%. We studied the influence of spontaneous breathing on measurement of cardiac output by thermodilution (TD) and central (CDD) and peripheral dye dilution (PDD) in seven anesthetized

  10. An update on insertable cardiac monitors

    DEFF Research Database (Denmark)

    Olsen, Flemming J; Biering-Sørensen, Tor; Krieger, Derk W

    2015-01-01

    Continuous cardiac rhythm monitoring has undergone compelling progress over the past decades. Cardiac monitoring has emerged from 12-lead electrocardiograms being performed at the discretion of the treating physician to in-hospital telemetry, Holter monitoring, prolonged external event monitoring...... turning point in the field of arrhythmia management. However, their role in the detection of paroxysmal atrial fibrillation after cryptogenic strokes has yet to evolve. This will be the main focus of this review. Issues surrounding patient selection, clinical relevance and determination of cost......-effectiveness for prolonged cardiac monitoring require further studies. Furthermore, insertable cardiac monitoring has not only the potential to augment diagnostic capabilities but also to improve the management of paroxysmal atrial fibrillation....

  11. Influence of continuous renal replacement therapy on cardiac output measurement using thermodilution techniques.

    Science.gov (United States)

    Heise, D; Faulstich, M; Mörer, O; Bräuer, A; Quintel, M

    2012-03-01

    Acute renal failure (ARF) ranks among the most frequent complications in critically ill patients and continuous renal replacement therapy (CRRT) is a typical treatment regimen in intensive care patients. Contributing factors to ARF, such as septic shock and hemodynamic instability require extended hemodynamic monitoring, and the simultaneous use of CRRT and cardiac output measurement is common. In view of this, a systematic analysis of the interaction between CRRT and cardiac output measurements by thermodilution is warranted. Cardiac output (CO) is commonly measured with thermodilution-based methods in critically ill patients. The methods are accurate but the measurements are affected by inconstant indicator volumes or changes in blood temperature. Because continuous renal replacement therapy (CRRT) may alter blood volume and temperature, we investigated its effect on thermodilution-based CO measurement. Thirty-two intensive care patients with both CRRT and CO monitoring were studied. Hemodynamic parameters were first measured in quintuple with bolus injections of cold saline during CRRT. Further five measurements were performed after CRRT had been shut off, and a final five measurements were performed after it had been restarted. Fifty measurement series were performed in patients with a pulmonary artery catheter and 25 in patients using a transpulmonary thermodilution method (PiCCO®). The first measurements in each series after switching CRRT off or on deviated most markedly from the average. When these measurements were excluded, the averaged CO values with and without CRRT differed significantly but by measurement error was only observed immediately after CRRT was switched off or on. Subsequent CO measurements did not depend on the CRRT status. Interrupting CRRT before measuring CO is not generally recommended, however, if interrupted, it is crucial to wait for blood temperature to reach a steady state before initiating the first measurements.

  12. A preliminary study evaluating cardiac output measurement using Pressure Recording Analytical Method (PRAM) in anaesthetized dogs.

    Science.gov (United States)

    Briganti, Angela; Evangelista, Flavia; Centonze, Paola; Rizzo, Annaliso; Bentivegna, Francesco; Crovace, Antonio; Staffieri, Francesco

    2018-03-06

    Haemodynamic variations normally occur in anaesthetized animals, in relation to the animal status, administered drugs, sympathetic and parasympathetic tone, fluid therapy and surgical stimulus. The possibility to measure some cardiovascular parameters, such as cardiac output (CO), during anaesthesia would be beneficial for both the anaesthesia management and its outcome. New techniques for the monitoring of CO are aimed at finding methods which are non invasive, accurate and with good trending ability, which can be used in a clinical setting. The aim of this study was to compare the Pressure Recording Analytical Method (PRAM) with the pulmonary artery thermodilution (TD) for the measurement of cardiac output in 6 anaesthetized critically ill dogs. Fifty-four pairs of CO measurements were obtained with a median (range) of 3.33 L/min (0.81-7.21) for PRAM-CO and 3.48 L/min (1.41-6.56) for TD-CO. The Bland-Altman analysis showed a mean bias of 0.17 L/min with limits of agreement (LoA) of - 0.46 to 0.81 L/min. The percentage error resulted 18.2%. The 4-quadrant plot analysis showed an acceptable concordance (93%) between the 2 methods. The polar plot showed a good trending ability with the mean angular bias of 3.9° and radial LoA ± 12.1°. The PRAM resulted in good precision, acceptable concordance and good trending ability for the measure of CO in the anaesthetized dog, representing a promising alternative to thermodilution for the measurement of CO. Among all the pulse contour methods available on the market it is the only one that does not require any calibration or adjustment of the measurement. Further studies are required to verify the ability of this method to accurately measure cardiac output even during unstable hemodynamic conditions.

  13. Cardiac output response to changes of the atrioventricular delay in different body positions and during exercise in patients receiving cardiac resynchronization therapy

    DEFF Research Database (Denmark)

    Ståhlberg, Marcus; Damgaard, Morten; Norsk, Peter

    2009-01-01

    AIMS: The aim of this study was to study the haemodynamic effect of atrioventricular delay (AVD) modifications within a narrow range in different body positions and during exercise in patients receiving cardiac resynchronization therapy (CRT). METHODS: The previously optimized AVD was shortened...... and prolonged by 40 ms in 27 CRT patients and 9 controls without heart failure. Cardiac output (CO) was measured by inert gas rebreathing (Innocor) as the average over different body positions (left-lateral, supine, sitting, standing, and exercise). In eight CRT patients with an implantable haemodynamic monitor.......61, Pnarrow range is larger in CRT patients than in normal...

  14. Kredsløbsmonitorering med lithium dilution cardiac output-systemet

    DEFF Research Database (Denmark)

    Christiansen, Christian; Hostrup, Anette; Tønnesen, Else

    2008-01-01

    The lithium dilution cardiac output (LiDCO) system measures cardiac output beat-to-beat with high precision. The system is based on an arterial pulse power analysis which is calibrated every eight hours with a small non-pharmacological dose of lithium. The system is minimally invasive; it require...... only a peripheral arterial catheter and a venous access. Dynamic parameters for early goal-directed therapy are also provided. Udgivelsesdato: 2008-Feb-11...

  15. [Non-invasive determination of cardiac output by continuous wave Doppler in air rescue service].

    Science.gov (United States)

    Knobloch, K; Hubrich, V; Rohmann, P; Lüpkemann, M; Phillips, R; Gerich, T; Krettek, C

    2005-12-01

    Determination of cardiac output (CO) enables to assess the hemodynamic situation as well as to administer optimal catecholamine therapy especially in critically compromised patients with hemodynamic instability. Invasive determination of CO is possible via a Swan-Ganz-catheter with its associated risk of implantation in the hospital. Using the Doppler technique, we evaluated the feasibility of the USCOM-system for non-invasive CO determination in preclinical emergency medicine in air rescue service. In 32 patients (17 months to 92-years-old) cardiac output was determined non-invasively (USCOM) at the scene and during the helicopter transport at Christoph 4, based at Hannover Medical School. Simultaneously, blood pressure, ECG and oxygen saturation were determined. Non-invasive CO was assessed by a suprasternal access aiming at the aorta ascendens. 19 patients were unconscious due to cardial and non-cardial reasons, and 13 were conscious (sepsis, status epilepticus, anaphylactic reaction). 7 patients were hemodynamically unstable. In three patients the monitor was used during interhospital transfer by helicopter. Non-invasively determined CO via the USCOM system was 4.8 +/- 0.7 l/min with a cardiac index of 2.4 +/- 0.3 l/m (2). Highest CO values were determined in a patient with sepsis and during a grand-mal-status in epilepsy (CO 8.2 l/min). All examinations were done by the same emergency physician of the emergency helicopter Christoph 4 immediately after arrival at the scene. The examination took on average 25 seconds. During the helicopter transport, several consecutive CO measurements were performed to assess volume and catecholamine therapy with increase of stroke volume after volume load with colloidal fluids. Using the USCOM system it is possible to determine the beat-to-beat cardiac output in air rescue service non-invasively. The emergency physician gains additional crucial hemodynamic information to diagnose and treat adequately by administration of

  16. Determination of myocardial energetic output for cardiac rhythm pacing

    Czech Academy of Sciences Publication Activity Database

    Heřman, D.; Převorovská, Světlana; Maršík, František

    2007-01-01

    Roč. 7, č. 4 (2007), s. 156-161 ISSN 1567-8822 R&D Projects: GA ČR GA106/03/1073 Institutional research plan: CEZ:AV0Z20760514 Keywords : heart arrhythmia * cardiac pacing modes * numerical simulation Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery

  17. [Comparison of continuous cardiac output measurement methods: non-invasive estimated CCO using pulse wave transit time and CCO using thermodilution].

    Science.gov (United States)

    Tsutsui, Masato; Yamada, Takashige; Sugo, Yoshihiro; Sato, Tetsufumi; Akazawa, Toshimasa; Sato, Nobukazu; Yamashita, Koichi; Ishihara, Hironori; Kazama, Tomiei; Takeda, Junzo

    2012-09-01

    esCCO (estimated continuous cardiac output, Nihon Kohden, esCCO) is a new cardiac output measurement system which uses pulse wave transit time to calculate cardiac output continuously and non-invasively. One of the most commonly used methods to monitor cardiac output is continuous cardiac output CCO (Edwards Lifesciences) which has an accuracy equivalent to that of thermodilution method. We compared esCCO to CCO in 67 operating room patients and 128 intensive care unit patients. CCO and esCCO were measured simultaneously in patients with a pulmonary artery catheter inserted after admission to the operating room or intensive care unit. CCO and esCCO showed a high correlation with a correlation coefficient of 0.84 in 496 total data points, and 95% limits of agreement between these two methods were -2.49 to 2.35 l x min(-1). This result suggests that esCCO could be used to measure cardiac output accurately and non-invasively in different cases.

  18. Cardiac Output Measurements in Septic Patients: Comparing the Accuracy of USCOM to PiCCO

    Directory of Open Access Journals (Sweden)

    Sophia Horster

    2012-01-01

    Full Text Available USCOM is an ultrasound-based method which has been accepted for noninvasive hemodynamic monitoring in various clinical conditions (USCOM, Ultrasonic cardiac output monitoring. The present study aimed at comparing the accuracy of the USCOM device with that of the thermodilution technique in patients with septicemia. We conducted a prospective observational study in a medical but noncardiological ICU of a university hospital. Septic adult patients (median age 55 years, median SAPS-II-Score 43 points on mechanical ventilation and catecholamine support were monitored with USCOM and PiCCO (=70. Seventy paired left-sided CO measurements (transaortic access = COUS-A were obtained. The mean COUS-A were 6.55 l/min (±2.19 versus COPiCCO 6.5 l/min (±2.18. The correlation coefficient was =0.89. Comparison by Bland-Altman analysis revealed a bias of −0.36 l/min (±0.99 l/min leading to a mean percentage error of 29%. USCOM is a feasible and rapid method to evaluate CO in septic patients. USCOM does reliably represent CO values as compared to the reference technique based on thermodilution (PiCCO. It seems to be appropriate in situations where CO measurements are most pertinent to patient management.

  19. [PULSE WAVE TRANSIT TIME - ONE MORE ATTEMPT OF NON-INVASIVE CARDIAC OUTPUT MEASUREMENT.

    Science.gov (United States)

    Akselrod, B A; Tolstova, L A; Pshenichniy, T A; Fedulova, S V

    2017-09-01

    Estimated continuous cardiac output (esCCOTM) based on pulse wave transit time is one of alternative non-invasive CO measurement techniques. Randomized study included 23 scheduled patients operated upon due to cardiovascular diseases. Cardiac index (CI) was measured Comparative analyses of esCCO and others CO measurement methods used intraoperative was carried out. In the first group (n = 9) esCCO was compared with transpulmonary thermodilution (PiCCO-plus); in the second group (n = 8) - with pulmonary artery thermodilution; in the third group (n = 6) - with transoesophageal echocardiography (velocity-time integral). In the 1st group direct correlation was found (r = 0,773, p measurements were out of reference interval (more than ? 15%). Blend- Altman method showed the dispersion of results in all groups. 1. Estimated continuous cardiac output measurement technique based on PWTT has a direct correla- tion with prepulmonary thermodilution and transoesophageal echocardiography, medium and high power respectively. 2. esCCO has significant differences with the referential techniques during general anesthesia in cardiac surgery pa- tients. 3. Calibration based on invasive blood pressure and outside cardiac output measurement does not increase the accuracy of measurements. 4. esCCO has a negative diagnostic value and cannot be recommendedfor the cardiac out- put evaluation during cardiac surgery. 5. This method can be useful for analyze general effectiveness of perioperative hemodynamics.

  20. Authentication of Radial Versus Femoral Arterial Pressure Waveform-Derived Cardiac Output With Transesophageal Echocardiography-Derived Cardiac Output Measurements in Patients Undergoing On-Pump Coronary Bypass Surgery.

    Science.gov (United States)

    Maddali, Madan Mohan; Waje, Niranjan Dilip; Sathiya, Panchatcharam Murthi

    2017-08-01

    The aim of this study was to ascertain if arterial waveform-derived cardiac output measurements from radial and femoral cannulation sites were reliable as compared with transesophageal echocardiography (TEE)-derived cardiac output (CO) values, and which of the CO measurements derived from radial and the femoral arterial pressure waveforms closely tracked simultaneously measured TEE-derived CO values. This study also aimed to ascertain if cardiopulmonary bypass (CPB) would impact the accuracy of arterial pressure-derived CO values from either of the 2 sites. A prospective observational study. Tertiary care cardiac center. Cardiac surgical patients undergoing on-pump primary coronary artery bypass surgery. Waveform-derived CO monitoring through radial and femoral artery cannulation using a FloTrac/Vigileo system. Twenty-seven consecutive cardiac surgical patients undergoing on-pump primary coronary artery bypass surgery were included in the study. Cardiac output was measured sequentially by the arterial pressure waveform analysis method from radial and femoral arterial sites and compared with simultaneously measured TEE-derived CO. Cardiac output data were obtained in triplicate at 6 predefined time intervals: before and after sternotomy, 5, 15, and 30 minutes after separation from CPB and prior to shifting the patient out of the operating room. The overall bias of the study was 0.11 and 0.27, the percentage error was 19.31 and 18.45, respectively, for radial and femoral arterial waveform-derived CO values as compared with TEE-derived CO measurements. The overall precision as compared with the TEE-derived CO values was 16.94 and 15.95 for the radial and femoral cannulation sites, respectively. The bias calculated by the Bland-Altman method suggested that CO measurements from the radial arterial site were in closer agreement with TEE-derived CO values at all time periods, and the relation was not affected by CPB. However, percentage error and precision calculations

  1. Remote Monitoring of Cardiac Implantable Electronic Devices.

    Science.gov (United States)

    Cheung, Christopher C; Deyell, Marc W

    2018-01-08

    Over the past decade, technological advancements have transformed the delivery of care for arrhythmia patients. From early transtelephonic monitoring to new devices capable of wireless and cellular transmission, remote monitoring has revolutionized device care. In this article, we review the current evolution and evidence for remote monitoring in patients with cardiac implantable electronic devices. From passive transmission of device diagnostics, to active transmission of patient- and device-triggered alerts, remote monitoring can shorten the time to diagnosis and treatment. Studies have shown that remote monitoring can reduce hospitalization and emergency room visits, and improve survival. Remote monitoring can also reduce the health care costs, while providing increased access to patients living in rural or marginalized communities. Unfortunately, as many as two-thirds of patients with remote monitoring-capable devices do not use, or are not offered, this feature. Current guidelines recommend remote monitoring and interrogation, combined with annual in-person evaluation in all cardiac device patients. Remote monitoring should be considered in all eligible device patients and should be considered standard of care. Copyright © 2018 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  2. Constant infusion transpulmonary thermodilution for the assessment of cardiac output in exercising humans

    DEFF Research Database (Denmark)

    Calbet, J A L; Mortensen, Stefan; Munch, G D W

    2016-01-01

    To determine the accuracy and precision of constant infusion transpulmonary thermodilution cardiac output (CITT-Q) assessment during exercise in humans, using indocyanine green (ICG) dilution and bolus transpulmonary thermodilution (BTD) as reference methods, cardiac output (Q) was determined...... at rest and during incremental one- and two-legged pedaling on a cycle ergometer, and combined arm cranking with leg pedaling to exhaustion in 15 healthy men. Continuous infusions of iced saline in the femoral vein (n = 41) or simultaneously in the femoral and axillary (n = 66) veins with determination......: 6.1-11.1%). In conclusion, cardiac output can be precisely and accurately determined with constant infusion transpulmonary thermodilution in exercising humans....

  3. Noninvasive measurement of cardiac output during exercise by inert gas rebreathing technique.

    Science.gov (United States)

    Cattadori, Gaia; Schmid, Jean-Paul; Agostoni, Piergiuseppe

    2009-04-01

    Reduced exercise tolerance and dyspnea during exercise are hallmarks of heart failure syndrome. Exercise capacity and various parameters of cardiopulmonary response to exercise are of important prognostic value. All the available parameters only indirectly reflect left ventricular dysfunction and hemodynamic adaptation to an increased demand. Noninvasive assessment of cardiac output, especially during an incremental exercise stress test, would allow the direct measure of cardiac reserve and may become the gold standard for prognostic evaluation in the future.

  4. Validation of a new spectrometer for noninvasive measurement of cardiac output

    Science.gov (United States)

    Baum, Marc M.; Kumar, Sasi; Moss, John A.; Wagner, Peter D.

    2004-07-01

    Acetylene is a blood-soluble gas and for many years its uptake rate during rebreathing tests has been used to calculate the flow rate of blood through the lungs (normally equal to cardiac output) as well as the volume of lung tissue. A new, portable, noninvasive instrument for cardiac output determination using the acetylene uptake method is described. The analyzer relies on nondispersive IR absorption spectroscopy as its principle of operation and is configured for extractive (side-stream) sampling. The instrument affords exceptionally fast (30 ms, 10%-90%, 90%-10%, at 500 mL min-1 flow rates), interference-free, simultaneous measurement of acetylene, sulfur hexafluoride (an insoluble reference gas used in the cardiac output calculation), and carbon dioxide (to determine alveolar ventilation), with good (typically ±2% full-scale) signal-to-noise ratios. Comparison tests with a mass spectrometer using serially diluted calibration gas samples gave excellent (R2>0.99) correlation for all three gases, validating the IR system's linearity and accuracy. A similar level of agreement between the devices also was observed during human subject C2H2 uptake tests (at rest and under incremental levels of exercise), with the instruments sampling a common extracted gas stream. Cardiac output measurements by both instruments were statistically equivalent from rest to 90% of maximal oxygen consumption; the physiological validity of the measurements was confirmed by the expected linear relationship between cardiac output and oxygen consumption, with both the slope and intercept in the published range. These results indicate that the portable, low-cost, rugged prototype analyzer discussed here is suitable for measuring cardiac output noninvasively in a point-of-care setting.

  5. Biphasic cardiac output changes during onset of spinal anaesthesia in elderly patients

    DEFF Research Database (Denmark)

    Meyhoff, C S; Hesselbjerg, L; Koscielniak-Nielsen, Z

    2007-01-01

    ended when the patients were ready for surgery, or if ephedrine was given to raise the mean arterial pressure. RESULTS: Cardiac output increased initially reaching a maximum after a mean of 7 min. The average increase was 1.1 L min(-1) (P... mmHg on average. At the end of data collection, cardiac output decreased 0.5 L min(-1) from baseline (P=0.02). Mean arterial pressure decreased progressively in all patients, and only minimal changes in heart rate were found. CONCLUSIONS: Using this high time-resolution method, we detected biphasic...

  6. Cardiac output measurement with transpulmonary ultrasound dilution is feasible in the presence of a left-to-right shunt: a validation study in lambs.

    NARCIS (Netherlands)

    Vrancken, S.L.A.G.; Boode, W.P. de; Hopman, J.C.W.; Singh, S.; Liem, K.D.; Heyst, A.F.J. van

    2012-01-01

    BACKGROUND: Cardiac output (CO) monitoring remains complex in newborns as most of the current technologies fail to accurately measure systemic blood flow in the presence of shunts. We validated CO measurements using transpulmonary ultrasound dilution (TPUD) in a neonatal lamb model with a

  7. In vitro, in vivo and numerical assessment of the working principle of the truCCOMS continuous cardiac output catheter system.

    Science.gov (United States)

    Claessens, T; Verwilst, P; Missant, C; Claus, P; Verdonck, P; Wouters, P; Segers, P

    2009-12-01

    The truCCOMS cardiac output monitor system provides a continuous and instantaneous measurement of cardiac output, derived from the amount of energy required for heating a filament to maintain a fixed 2 degrees C blood temperature difference between two thermistors located distally on a pulmonary artery catheter. Clinical studies, however, reported relatively poor accuracy of the cardiac output estimation, possibly due to linearly assumed power-cardiac output relationship used for calibration of the catheters. We experimentally studied the shape of the truCCOMS calibration relationship (i) in a hydraulic bench model of the right heart and (ii) in vivo intact animal model. The results showed a nonlinear relationship between the power input into the heating element and the cardiac output; which could satisfactorily be described with an exponential relationship. Comparison of the performance of the same catheters in vitro and in vivo showed that the in vitro determined calibration relationship should not be used for in vivo measurements. Finally, we also simulated the working principle of the catheter using a simplified numerical model of the blood flow and heat transfer around the catheter. The computed results also suggested a pronounced nonlinear relationship between power and cardiac output in pulsatile conditions. We conclude that the observed over- and underestimation of high- and low flows, respectively, by the current truCCOMS system is likely to arise from its linear calibration relationship. An appropriate calibration scheme accounting for the intrinsic nonlinear power-cardiac output relationship and the difference between in vitro and in vivo conditions should improve the clinical performance of the system.

  8. Rowing increases stroke volume and cardiac output to a greater extent than cycling

    Czech Academy of Sciences Publication Activity Database

    Horn, P.; Ošťádal, P.; Ošťádal, Bohuslav

    2015-01-01

    Roč. 64, č. 2 (2015), s. 203-207 ISSN 0862-8408 Institutional support: RVO:67985823 Keywords : cardiac output * cycling * heart rate * stroke volume Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery Impact factor: 1.643, year: 2015

  9. Transpulmonary thermodilution cardiac output measurement is not affected by severe pulmonary oedema: a newborn animal study

    NARCIS (Netherlands)

    Nusmeier, A.; Vrancken, S.L.; Boode, W.P. de; Hoeven, J.G. van der; Lemson, J.

    2013-01-01

    BACKGROUND: /st> The transpulmonary thermodilution (TPTD) technique is widely used in clinical practice for measuring cardiac output (CO). This study was designed to investigate the influence of various levels of pulmonary oedema on the reliability of CO measurements by the TPTD method. METHODS:

  10. Middle cerebral artery blood velocity depends on cardiac output during exercise with a large muscle mass

    NARCIS (Netherlands)

    Ide, K.; Pott, F.; van Lieshout, J. J.; Secher, N. H.

    1998-01-01

    We tested the hypothesis that pharmacological reduction of the increase in cardiac output during dynamic exercise with a large muscle mass would influence the cerebral blood velocity/perfusion. We studied the relationship between changes in cerebral blood velocity (transcranial Doppler), rectus

  11. Effect of Hemorrhage on Cardiac Output, PVP, Alodosterone and Diuresis during Immersion in Men

    Science.gov (United States)

    Simanonok, K.; Greenleaf, John E.; Bernauer, E. M.; Wade, C. E.; Keil, L. C.

    1990-01-01

    The purpose of this study was to test the hypothesis that a reduction in blood volume would attenuate or eliminate immersion-induced increases in cardiac output (Q (sup dot) sub co)) and urine excretion, and to investigate accompanying vasoactive and fluid-electrolyte hormonal responses.

  12. Cardiac output and vasodilation in the vasovagal response: An analysis of the classic papers

    NARCIS (Netherlands)

    Wieling, Wouter; Jardine, David L.; de Lange, Frederik J.; Brignole, Michele; Nielsen, Henning B.; Stewart, Julian; Sutton, Richard

    2016-01-01

    The simple faint is secondary to hypotension and bradycardia resulting in transient loss of consciousness. According to Ohm's law applied to the circulation, BP = SVR × CO, hypotension can result from a decrease in systemic vascular resistance (SVR), cardiac output (CO), or both. It is important to

  13. Resistance training improves cardiac output, exercise capacity and tolerance to positive airway pressure in Fontan physiology.

    Science.gov (United States)

    Cordina, Rachael L; O'Meagher, Shamus; Karmali, Alia; Rae, Caroline L; Liess, Carsten; Kemp, Graham J; Puranik, Raj; Singh, Nalin; Celermajer, David S

    2013-09-30

    Subjects with Fontan-type circulation have no sub-pulmonary ventricle and thus depend exquisitely on the respiratory bellows and peripheral muscle pump for cardiac filling. We hypothesised that resistance training to augment the peripheral muscle pump might improve cardiac filling, reduce inspiratory-dependence of IVC return to the heart and thus improve exercise capacity and cardiac output on constant positive airway pressure (CPAP). Eleven Fontan subjects (32+/-2 years, mean+/-SEM) had cardiac magnetic resonance imaging (MRI) and exercise testing (CPET); six underwent 20 weeks of high-intensity resistance training; others were non-exercising controls. After training, CPET was repeated. Four trainers had MRI with real-time flow measurement at rest, exercise and on CPAP in the trained state and following a 12-month detrain. In the trained state, muscle strength increased by 43% (p=0.002), as did total muscle mass (by 1.94 kg, p=0.003) and peak VO2 (by 183 ml/min, p=0.02). After detraining, calf muscle mass and peak workload had fallen significantly (pexercise (by 16 ml, p=0.04); inspiratory-dependent IVC blood return during exercise was 40% higher (p=0.02). On CPAP, cardiac output was lower in the detrained state (101 vs. 77 ml/s, p=0.03). Resistance muscle training improves muscle mass, strength and is associated with improved cardiac filling, stroke volume, exercise capacity and cardiac output on CPAP, in adults with Fontan-type circulation. Crown Copyright © 2012. Published by Elsevier Ireland Ltd. All rights reserved.

  14. The accuracy of PiCCO® in measuring cardiac output in patients under therapeutic hypothermia: Comparison with transthoracic echocardiography.

    Science.gov (United States)

    Souto Moura, T; Aguiar Rosa, S; Germano, N; Cavaco, R; Sequeira, T; Alves, M; Papoila, A L; Bento, L

    2018-03-01

    Invasive cardiac monitoring using thermodilution methods such as PiCCO® is widely used in critically ill patients and provides a wide range of hemodynamic variables, including cardiac output (CO). However, in post-cardiac arrest patients subjected to therapeutic hypothermia, the low body temperature possibly could interfere with the technique. Transthoracic Doppler echocardiography (ECHO) has long proved its accuracy in estimating CO, and is not influenced by temperature changes. To assess the accuracy of PiCCO® in measuring CO in patients under therapeutic hypothermia, compared with ECHO. Thirty paired COECHO/COPiCCO measurements were analyzed in 15 patients subjected to hypothermia after cardiac arrest. Eighteen paired measurements were obtained at under 36°C and 12 at ≥36°C. A value of 0.5l/min was considered the maximum accepted difference between the COECHO and COPiCCO values. Under conditions of normothermia (≥36°C), the mean difference between COECHO and COPiCCO was 0.030 l/min, with limits of agreement (-0.22, 0.28) - all of the measurements differing by less than 0.5 l/min. In situations of hypothermia (<36°C), the mean difference in CO measurements was -0.426 l/min, with limits of agreement (-1.60, 0.75), and only 44% (8/18) of the paired measurements fell within the interval (-0.5, 0.5). The calculated temperature cut-off point maximizing specificity was 35.95°C: above this temperature, specificity was 100%, with a false-positive rate of 0%. The results clearly show clinically relevant discordance between COECHO and COPiCCO at temperatures of <36°C, demonstrating the inaccuracy of PiCCO® for cardiac output measurements in hypothermic patients. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  15. Risk for decreased cardiac output: validation of a proposal for nursing diagnosis.

    Science.gov (United States)

    Pereira de Melo, Renata; Venícios de Oliveira Lopes, Marcos; Leite de Araujo, Thelma; de Fatima da Silva, Lucia; Aline Arrais Sampaio Santos, Francisca; Moorhead, Sue

    2011-01-01

    To verify the content validity of the nursing diagnosis risk for decreased cardiac output (RDCO). DCO is a phenomenon that is not restricted to individuals or environments that specifically focus on cardiovascular care. It is not only prevalent in cardiovascular care units, but also in post-anaesthesia units and non-cardiac care units among individuals with non-cardiogenic disorders. A significant decrease in cardiac output is a life-threatening situation, demonstrating the need for developing a risk nursing diagnosis for early intervention. The development of this diagnosis requires the construction of a diagnosis label, a definition of the diagnostic concept and the risk factors associated with the diagnosis. The research was carried out in two methodological stages based on the Fehring diagnosis content validation model. The quantitative analysis consisted of the calculation of the weighted mean of the values attributed by experts to each risk factor, the level of agreement/disagreement between the experts regarding the operational definitions of risk factors and the index of diagnostic content validity (DCV). The label 'risk for decreased cardiac output' was considered representative of a nursing diagnosis defined as 'at risk of developing a health status characterized by an insufficient quantity of blood pumped by the heart to meet physical metabolic demands'. Critical risk factors (DCV ≥ 0·7) were myocardial dysfunction (0·887), blood loss (0·875), increase in intrapericardial pressure (0·825), condition that leads to changes in cardiac rhythm and/or electrical conduction (0·812), deficient fluid volume (0·725), plasma loss (0·712), ineffective tissue perfusion (0·712) and electrolyte imbalance (0·7). The research identified eight risk factors with valid content for assessment of RDCO. The identification of risk factors for DCO assists nurses to intervene early and minimize the consequences of a deficient cardiac function. © 2011 The Authors

  16. Arterial pressure-based cardiac output in septic patients: different accuracy of pulse contour and uncalibrated pressure waveform devices

    OpenAIRE

    Monnet, Xavier; Anguel, Nadia; Naudin, Brice; Jabot, Julien; Richard, Christian; Teboul, Jean-Louis

    2010-01-01

    Introduction We compared the ability of two devices estimating cardiac output from arterial pressure-curve analysis to track the changes in cardiac output measured with transpulmonary thermodilution induced by volume expansion and norepinephrine in sepsis patients. Methods In 80 patients with septic circulatory failure, we administered volume expansion (40 patients) or introduced/increased norepinephrine (40 patients). We measured the pulse contour-derived cardiac index (CI) provided by the P...

  17. CMR fluoroscopy right heart catheterization for cardiac output and pulmonary vascular resistance: results in 102 patients.

    Science.gov (United States)

    Rogers, Toby; Ratnayaka, Kanishka; Khan, Jaffar M; Stine, Annette; Schenke, William H; Grant, Laurie P; Mazal, Jonathan R; Grant, Elena K; Campbell-Washburn, Adrienne; Hansen, Michael S; Ramasawmy, Rajiv; Herzka, Daniel A; Xue, Hui; Kellman, Peter; Faranesh, Anthony Z; Lederman, Robert J

    2017-07-27

    Quantification of cardiac output and pulmonary vascular resistance (PVR) are critical components of invasive hemodynamic assessment, and can be measured concurrently with pressures using phase contrast CMR flow during real-time CMR guided cardiac catheterization. One hundred two consecutive patients underwent CMR fluoroscopy guided right heart catheterization (RHC) with simultaneous measurement of pressure, cardiac output and pulmonary vascular resistance using CMR flow and the Fick principle for comparison. Procedural success, catheterization time and adverse events were prospectively collected. RHC was successfully completed in 97/102 (95.1%) patients without complication. Catheterization time was 20 ± 11 min. In patients with and without pulmonary hypertension, baseline mean pulmonary artery pressure was 39 ± 12 mmHg vs. 18 ± 4 mmHg (p < 0.001), right ventricular (RV) end diastolic volume was 104 ± 64 vs. 74 ± 24 (p = 0.02), and RV end-systolic volume was 49 ± 30 vs. 31 ± 13 (p = 0.004) respectively. 103 paired cardiac output and 99 paired PVR calculations across multiple conditions were analyzed. At baseline, the bias between cardiac output by CMR and Fick was 5.9% with limits of agreement -38.3% and 50.2% with r = 0.81 (p < 0.001). The bias between PVR by CMR and Fick was -0.02 WU.m 2 with limits of agreement -2.6 and 2.5 WU.m 2 with r = 0.98 (p < 0.001). Correlation coefficients were lower and limits of agreement wider during physiological provocation with inhaled 100% oxygen and 40 ppm nitric oxide. CMR fluoroscopy guided cardiac catheterization is safe, with acceptable procedure times and high procedural success rate. Cardiac output and PVR measurements using CMR flow correlated well with the Fick at baseline and are likely more accurate during physiological provocation with supplemental high-concentration inhaled oxygen. Clinicaltrials.gov NCT01287026 , registered January 25, 2011.

  18. Evaluation of Resting Cardiac Power Output as a Prognostic Factor in Patients with Advanced Heart Failure.

    Science.gov (United States)

    Yildiz, Omer; Aslan, Gamze; Demirozu, Zumrut T; Yenigun, Cemal Deniz; Yazicioglu, Nuran

    2017-09-15

    If the heart is represented by a hydraulic pump, cardiac power represents the hydraulic function of the heart. Cardiac pump function is frequently determined through left ventricular ejection fraction using imaging. This study aims to validate resting cardiac power output (CPO) as a predictive biomarker in patients with advanced heart failure (HF). One hundred and seventy-two patients with HF severe enough to warrant cardiac transplantation were retrospectively reviewed at a single tertiary care institution between September 2010 and July 2013. Patients were initially evaluated with simultaneous right-sided and left-sided cardiac catheter-based hemodynamic measurements, followed by longitudinal follow-up (median of 52 months) for adverse events (cardiac mortality, cardiac transplantation, or ventricular assist device placement). Median resting CPO was 0.54 W (long rank chi-square = 33.6; p < 0.0001). Decreased resting CPO (<0.54 W) predicted increased risk for adverse outcomes. Fifty cardiac deaths, 10 cardiac transplants, and 12 ventricular assist device placements were documented. The prognostic relevance of resting CPO remained significant after adjustment for age, gender, left ventricular ejection fraction, mean arterial pressure, pulmonary vascular resistance, right atrial pressure, and estimated glomerular filtration rate (HR, 3.53; 95% confidence interval, 1.66 to 6.77; p = 0.0007). In conclusion, lower resting CPO supplies independent prediction of adverse outcomes. Thus, it could be effectively used for risk stratification in patients with advanced HF. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Cardiac optogenetics : using light to monitor cardiac physiology

    NARCIS (Netherlands)

    Koopman, Charlotte D.|info:eu-repo/dai/nl/41375491X; Zimmermann, Wolfram-Hubertus; Knöpfel, Thomas; de Boer, Teun P.|info:eu-repo/dai/nl/30481878X

    2017-01-01

    Our current understanding of cardiac excitation and its coupling to contraction is largely based on ex vivo studies utilising fluorescent organic dyes to assess cardiac action potentials and signal transduction. Recent advances in optogenetic sensors open exciting new possibilities for cardiac

  20. Is pulmonary gas exchange during exercise in hypoxia impaired with the increase of cardiac output?

    DEFF Research Database (Denmark)

    Calbet, J.A.; Robach, P.; Lundby, C.

    2008-01-01

    During exercise in humans, the alveolar-arterial O(2) tension difference ((A-a)DO(2)) increases with exercise intensity and is an important factor determining the absolute level of oxygen binding to hemoglobin and therefore the level of systemic oxygen transport. During exercise in hypoxia, the (A......-a)DO(2) is accentuated. Using the multiple inert gas elimination technique it has been shown that during exercise in acute hypoxia the contribution of ventilation-perfusion inequality to (A-a)DO(2) is rather small and in the absence of pulmonary edema intrapulmonary shunts can be ruled out. This implies...... that the main mechanism limiting pulmonary gas exchange is diffusion limitation. It is presumed that an elevation of cardiac output during exercise in acute hypoxia should increase the (A-a)DO(2). However, no studies have examined how variations in cardiac output independently affect pulmonary diffusion...

  1. Levosimendan in a neonate with severe coarctation of aorta and low cardiac output syndrome

    Directory of Open Access Journals (Sweden)

    Yann Olivier Boegli

    2013-01-01

    Full Text Available We report successful use of levosimendan after failed balloon angioplasty in a critically ill neonate with coarctation of aorta (CoA and severe low cardiac output syndrome (LCOS. Treatment with levosimendan improved left heart function, and decreased lactate and brain natriuretic peptide levels. To our knowledge, this is the first report on the safe and successful use of levosimendan in the management of LCOS due to severe CoA in a neonate awaiting surgical repair.

  2. Measurements of cardiac output obtained with transesophageal echocardiography and pulmonary artery thermodilution are not interchangeable

    DEFF Research Database (Denmark)

    Møller-Sørensen, H; Graeser, K; Hansen, K L

    2014-01-01

    BACKGROUND: Echocardiography is increasingly becoming an integrated tool for circulatory evaluation in the intensive care unit and the operating room. Therefore, it is imperative to know the reproducibility of measurements obtained by echocardiography. In this study, a comparison of cardiac output...... (CO) measurements obtained with transesophageal echocardiography (TEE) and pulmonary artery catheter (PAC) thermodilution (TD) was carried out to test the precision, accuracy and trending ability of CO measurements obtained with TEE. METHODS: Twenty-five patients completed the study. Each patient...

  3. Prototype development of an electrical impedance based simultaneous respiratory and cardiac monitoring system for gated radiotherapy.

    Science.gov (United States)

    Kohli, Kirpal; Liu, Jeff; Schellenberg, Devin; Karvat, Anand; Parameswaran, Ash; Grewal, Parvind; Thomas, Steven

    2014-10-14

    In radiotherapy, temporary translocations of the internal organs and tumor induced by respiratory and cardiac activities can undesirably lead to significantly lower radiation dose on the targeted tumor but more harmful radiation on surrounding healthy tissues. Respiratory and cardiac gated radiotherapy offers a potential solution for the treatment of tumors located in the upper thorax. The present study focuses on the design and development of simultaneous acquisition of respiratory and cardiac signal using electrical impedance technology for use in dual gated radiotherapy. An electronic circuitry was developed for monitoring the bio-impedance change due to respiratory and cardiac motions and extracting the cardiogenic ECG signal. The system was analyzed in terms of reliability of signal acquisition, time delay, and functionality in a high energy radiation environment. The resulting signal of the system developed was also compared with the output of the commercially available Real-time Position Management™ (RPM) system in both time and frequency domains. The results demonstrate that the bioimpedance-based method can potentially provide reliable tracking of respiratory and cardiac motion in humans, alternative to currently available methods. When compared with the RPM system, the impedance-based system developed in the present study shows similar output pattern but different sensitivities in monitoring different respiratory rates. The tracking of cardiac motion was more susceptible to interference from other sources than respiratory motion but also provided synchronous output compared with the ECG signal extracted. The proposed hardware-based implementation was observed to have a worst-case time delay of approximately 33 ms for respiratory monitoring and 45 ms for cardiac monitoring. No significant effect on the functionality of the system was observed when it was tested in a radiation environment with the electrode lead wires directly exposed to high-energy X

  4. Uncalibrated continuous cardiac output measurement in liver transplant patients: LiDCOrapid™ system versus pulmonary artery catheter.

    Science.gov (United States)

    Costa, Maria Gabriella; Chiarandini, Paolo; Scudeller, Luigia; Vetrugno, Luigi; Pompei, Livia; Serena, Giovanni; Buttera, Stefania; Della Rocca, Giorgio

    2014-06-01

    The aim of the study was to assess the level of agreement between continuous cardiac output estimated by uncalibrated pulse-power analysis (PulseCOLiR) and intermittent (ICO) and continuous cardiac output (CCO) obtained using a pulmonary artery catheter (PAC). Prospective cohort study. University hospital intensive care unit. Twenty patients after liver transplantation. Pulmonary artery catheters were placed in all patients, and ICO and CCO were determined using thermodilution. PulseCOLiR measurements were made using a LiDCOrapid(TM) (LiDCO Ltd, Cambridge, UK). ICO data were determined after intensive care unit admission and every 8 hours until the 48th postoperative hour. CCO and PulseCOLiR measurements were recorded simultaneously at these same time intervals as well as hourly. For the 8-hour data set (140 data pairs), the mean bias and percentage errors (PE) were, respectively,-0.10 L/min and 39.2% for ICO versus PulseCOLiR and 0.79 L/min and 34.6% for CCO versus PulseCOLiR. For the hourly comparison of CCO versus PulseCOLiR (980 data pairs), the bias was 0.75 L/min and the PE 37%. To assess the ability to measure change, a 4-quadrant plot was produced for each pair of methods. The performance of PulseCOLiR was moderate in detecting changes in ICO. In conclusion, the uncalibrated PulseCOLir method should not be used as a substitute for the thermodilution technique for the monitoring of cardiac output in liver transplant patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Noninvasive cardiac output measurement by transthoracic electrical bioimpedence: influence of age and gender.

    Science.gov (United States)

    Sathyaprabha, Talakad N; Pradhan, Cauchy; Rashmi, G; Thennarasu, Kandavel; Raju, Trichur R

    2008-12-01

    Thoracic electrical bioimpedance (TEB) as a method of measuring cardiac output (CO) is being explored increasingly over the last two decades, as a non-invasive alternative to the pulmonary artery catheter. The objective of this study was to establish normative data for measurement of CO by TEB and define the effect of age and gender on CO. Stroke volume (SV) of 397 normal individuals (203 men, 194 women) in the age range of 10-77 years was determined using Kubisek and Bernstein formulae by TEB method. Derived cardiac parameters including CO, cardiac index (CI), systemic vascular resistance and resistance index were calculated and analyzed. We found significant difference in CO among age groups and between gender. CO between Kubicek formula and Bernstein formula correlated well, but their means differed significantly. Cardiac indices peak in the third and seventh decade and were comparable between genders. A comprehensive data set of normalized values expressed as 95% confidence interval and mean +/- SD in different age groups and different gender was possible for cardiac parameters using TEB.

  6. Pulmonary Artery Catheter (PAC Accuracy and Efficacy Compared with Flow Probe and Transcutaneous Doppler (USCOM: An Ovine Cardiac Output Validation

    Directory of Open Access Journals (Sweden)

    Robert A. Phillips

    2012-01-01

    Full Text Available Background. The pulmonary artery catheter (PAC is an accepted clinical method of measuring cardiac output (CO despite no prior validation. The ultrasonic cardiac output monitor (USCOM is a noninvasive alternative to PAC using Doppler ultrasound (CW. We compared PAC and USCOM CO measurements against a gold standard, the aortic flow probe (FP, in sheep at varying outputs. Methods. Ten conscious sheep, with implanted FPs, had measurements of CO by FP, USCOM, and PAC, at rest and during intervention with inotropes and vasopressors. Results. CO measurements by FP, PAC, and USCOM were 4.0±1.2 L/min, 4.8±1.5 L/min, and 4.0±1.4 L/min, respectively, (=280, range 1.9 L/min to 11.7 L/min. Percentage bias and precision between FP and PAC, and FP and USCOM was −17 and 47%, and 1 and 36%, respectively. PAC under-measured Dobutamine-induced CO changes by 20% (relative 66% compared with FP, while USCOM measures varied from FP by 3% (relative 10%. PAC reliably detected −30% but not +40% CO changes, as measured by receiver operating characteristic area under the curve (AUC, while USCOM reliably detected ±5% changes in CO (AUC>0.70. Conclusions. PAC demonstrated poor accuracy and sensitivity as a measure of CO. USCOM provided equivalent measurements to FP across a sixfold range of outputs, reliably detecting ±5% changes.

  7. Monitoring radiation use in cardiac fluoroscopy imaging procedures

    International Nuclear Information System (INIS)

    Stevens, Nathaniel T.; Steiner, Stefan H.; Smith, Ian R.; MacKay, R. Jock

    2011-01-01

    Purpose: Timely identification of systematic changes in radiation delivery of an imaging system can lead to a reduction in risk for the patients involved. However, existing quality assurance programs involving the routine testing of equipment performance using phantoms are limited in their ability to effectively carry out this task. To address this issue, the authors propose the implementation of an ongoing monitoring process that utilizes procedural data to identify unexpected large or small radiation exposures for individual patients, as well as to detect persistent changes in the radiation output of imaging platforms. Methods: Data used in this study were obtained from records routinely collected during procedures performed in the cardiac catheterization imaging facility at St. Andrew's War Memorial Hospital, Brisbane, Australia, over the period January 2008-March 2010. A two stage monitoring process employing individual and exponentially weighted moving average (EWMA) control charts was developed and used to identify unexpectedly high or low radiation exposure levels for individual patients, as well as detect persistent changes in the radiation output delivered by the imaging systems. To increase sensitivity of the charts, we account for variation in dose area product (DAP) values due to other measured factors (patient weight, fluoroscopy time, and digital acquisition frame count) using multiple linear regression. Control charts are then constructed using the residual values from this linear regression. The proposed monitoring process was evaluated using simulation to model the performance of the process under known conditions. Results: Retrospective application of this technique to actual clinical data identified a number of cases in which the DAP result could be considered unexpected. Most of these, upon review, were attributed to data entry errors. The charts monitoring the overall system radiation output trends demonstrated changes in equipment performance

  8. Monitoring radiation use in cardiac fluoroscopy imaging procedures

    Energy Technology Data Exchange (ETDEWEB)

    Stevens, Nathaniel T.; Steiner, Stefan H.; Smith, Ian R.; MacKay, R. Jock [Department of Statistics and Actuarial Sciences, Business and Industrial Statistics Research Group, University of Waterloo, Waterloo, Ontario N2L 3G1 (Canada); St. Andrew' s Medical Institute, St. Andrew' s War Memorial Hospital, Brisbane, Queensland 4000 (Australia); Department of Statistics and Actuarial Sciences, Business and Industrial Statistics Research Group, University of Waterloo, Waterloo, Ontario N2L 3G1 (Canada)

    2011-01-15

    Purpose: Timely identification of systematic changes in radiation delivery of an imaging system can lead to a reduction in risk for the patients involved. However, existing quality assurance programs involving the routine testing of equipment performance using phantoms are limited in their ability to effectively carry out this task. To address this issue, the authors propose the implementation of an ongoing monitoring process that utilizes procedural data to identify unexpected large or small radiation exposures for individual patients, as well as to detect persistent changes in the radiation output of imaging platforms. Methods: Data used in this study were obtained from records routinely collected during procedures performed in the cardiac catheterization imaging facility at St. Andrew's War Memorial Hospital, Brisbane, Australia, over the period January 2008-March 2010. A two stage monitoring process employing individual and exponentially weighted moving average (EWMA) control charts was developed and used to identify unexpectedly high or low radiation exposure levels for individual patients, as well as detect persistent changes in the radiation output delivered by the imaging systems. To increase sensitivity of the charts, we account for variation in dose area product (DAP) values due to other measured factors (patient weight, fluoroscopy time, and digital acquisition frame count) using multiple linear regression. Control charts are then constructed using the residual values from this linear regression. The proposed monitoring process was evaluated using simulation to model the performance of the process under known conditions. Results: Retrospective application of this technique to actual clinical data identified a number of cases in which the DAP result could be considered unexpected. Most of these, upon review, were attributed to data entry errors. The charts monitoring the overall system radiation output trends demonstrated changes in equipment

  9. Mathematical basis for the measurement of absolute and fractional cardiac output with diffusible tracers by compartmental analysis methods

    International Nuclear Information System (INIS)

    Charkes, N.D.

    1984-01-01

    Using compartmental analysis methods, a mathematical basis is given for the measurement of absolute and fractional cardiac output with diffusible tracers. Cardiac output is shown to be the product of the blood volume and the sum of the rate constants of tracer egress from blood, modified by a factor reflecting transcapillary diffusibility, the transfer fraction. The return of tracer to the blood and distant (intracellular) events are shown to play no role in the solution. Fractional cardiac output is the ratio of the rate constant of tracer egress from blood to an organ, divided by the sum of the egress constants from blood. Predominantly extracellular ions such as sodium or bromide are best suited for this technique, although theoretically any diffusible tracer whose compartmental model can be solved may be used. It is shown that fractional cardiac output is independent of the transfer fraction, and therefore can be measured accurately by tracers which are not freely diffusible

  10. Experience with Mechanical Circulatory Support for Medically Intractable Low Cardiac Output in a Pediatric Intensive Care Unit.

    Science.gov (United States)

    Park, Jung Bin; Kwak, Jae Gun; Lim, Hong-Gook; Kim, Woong-Han; Lee, Jeong Ryul; Kim, Yong Jin

    2017-07-01

    Mechanical circulatory support with extracorporeal membrane oxygenation (ECMO) and ventricular assist device has always been the optimal choice for treating the majority of medically intractable low cardiac output case. We retrospectively investigated our institution's outcomes and variables associated with a high risk of mortality. From 1999 to 2014, 86 patients who were of pediatric age or had grown-up congenital heart disease underwent mechanical circulatory support for medically intractable low cardiac output in our pediatric intensive care unit. Of these, 9 grown-up congenital heart disease patients were over 18 years of age, and the median age of the subject group was 5.82 years (range: 1 day to 41.6 years). A review of all demographic, clinical, and surgical data and survival analysis were performed. A total of 45 (52.3%) patients were successfully weaned from the mechanical assist device, and 25 (29.1%) survivors were able to be discharged. There was no significant difference in results between patients over 18 years and under 18 years of age. Risk factors for mortality were younger age (metabolic acidosis and increased levels of lactate, creatinine, bilirubin, or liver enzyme). The survival rate has improved since 2010 (from 25% before 2010 to 35% after 2010), when we introduced an upgraded oxygenator, activated heart transplantation, and also began to apply ECMO before the end-stage of cardiac dysfunction, even though we could not reveal significant correlations between survival rate and changed strategies associated with ECMO. Mechanical circulatory support has played a critical role and has had a dramatic effect on survival in patients with medically intractable heart failure, particularly in recent years. Meticulous monitoring of acid-base status, laboratory findings, and early and liberal applications are recommended to improve outcomes without critical complication rates, particularly in neonates with single ventricle physiology.

  11. Low Cardiac Output Leads Hepatic Fibrosis in Right Heart Failure Model Rats

    Science.gov (United States)

    Fujimoto, Yoshitaka; Urashima, Takashi; Shimura, Daisuke; Ito, Reiji; Kawachi, Sadataka; Kajimura, Ichige; Akaike, Toru; Kusakari, Yoichiro; Fujiwara, Masako; Ogawa, Kiyoshi; Goda, Nobuhito; Ida, Hiroyuki; Minamisawa, Susumu

    2016-01-01

    Background Hepatic fibrosis progresses with right heart failure, and becomes cardiac cirrhosis in a severe case. Although its causal factor still remains unclear. Here we evaluated the progression of hepatic fibrosis using a pulmonary artery banding (PAB)-induced right heart failure model and investigated whether cardiac output (CO) is responsible for the progression of hepatic fibrosis. Methods and Results Five-week-old Sprague-Dawley rats divided into the PAB and sham-operated control groups. After 4 weeks from operation, we measured CO by echocardiography, and hepatic fibrosis ratio by pathological examination using a color analyzer. In the PAB group, CO was significantly lower by 48% than that in the control group (78.2±27.6 and 150.1±31.2 ml/min, Pright failure heart model rats. PMID:26863419

  12. Non-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing technique

    DEFF Research Database (Denmark)

    Gabrielsen, Anders; Videbaek, Regitze; Schou, Morten

    2002-01-01

    Values of effective pulmonary blood flow (Q(EP)) and cardiac output, determined by a non-invasive foreign gas rebreathing method (CO(RB)) using a new infrared photoacoustic gas analysing system, were compared with measurements of cardiac output obtained by the direct Fick (CO(FICK)) and thermodil......Values of effective pulmonary blood flow (Q(EP)) and cardiac output, determined by a non-invasive foreign gas rebreathing method (CO(RB)) using a new infrared photoacoustic gas analysing system, were compared with measurements of cardiac output obtained by the direct Fick (CO...... with significant shunt flow. In the eight patients without significant shunt flow, the agreement between Q(EP) and CO(FICK) was 0.3 +/- 0.9 litre x min(-1). In conclusion, a foreign gas rebreathing method with a new infrared photoacoustic gas analyser provided at least as reliable a measure of cardiac output...... as did thermodilution. In the absence of significant shunt flow, measurement of Q(EP) itself provides a reliable estimate of cardiac output in heart failure patients. The infrared photoacoustic gas analyser markedly facilitates clinical use of the rebreathing method in general, which makes the method...

  13. Correlation of cardiac output and sevoflurane required to maintain anesthetic depth targeted with entropy index.

    Science.gov (United States)

    Bautin, Andrei E; Siganevich, Ann V; Malaya, Elena Y; Khomenko, Evgenii A; Gordeev, Mikhail L; Solntsev, Vladislav N

    2014-01-01

    We investigated the correlation of reduced cardiac output on required sevoflurane to maintain targeted anesthesia depth. 36 patients undergoing coronary artery bypass grafting with cardiopulmonary bypass were prospectively included in the study. Inspired sevoflurane concentration was adjusted to ensure state entropy index 2.2 l/min/m2 (1.37% ± 0.31%), P = 0.01. Relationship between CI and ETsev required for maintaining target level of anesthesia is non-linear. Patients with CI ≤ 2.2 l/min/m2 need lower levels of the ETsev for maintenance of the target anesthesia at an entropy index < 40.

  14. Hereditary Hemorrhagic Telangiectasia Presenting as High Output Cardiac Failure during Pregnancy

    Directory of Open Access Journals (Sweden)

    Tareq Goussous

    2009-01-01

    Full Text Available High-output cardiac failure secondary to hepatic involvement is a rare complication of hereditary hemorrhagic telangiectasia (HHT. Here we report a 43-year-old woman who presented at 29 weeks gestation of her second pregnancy with complications of right-sided heart failure and preterm labor. After delivery via cesarean section, the patient was found to have intrahepatic arteriovenous malformations through non-invasive imaging. Subsequently, a family history of vascular malformations and epistaxis was elucidated and a diagnosis of HHT was made. This case is presented, along with a review of the literature and discussion of hepatic involvement in HHT with particular focus on the pregnant patient.

  15. Depressed left and right ventricular cardiac output in fetuses of diabetic mothers.

    Science.gov (United States)

    Winter, Jennifer; Kulkarni, Aparna; Craft, Mary; Li, Ling; Hornberger, Lisa; Danford, David A; Kutty, Shelby

    2018-01-15

    We compared right and left ventricular cardiac output (RVCO and LVCO) in fetuses of diabetic mothers (FDM) to a large normal cohort. We prospectively enrolled 264 normal fetuses and 30 FDM. Fetal CO parameters: semilunar valve velocity time integrals (AVVTI, PVVTI), ventricular outflow diameters (LVOTD, RVOTD), stroke volumes (AVSV, PVSV) were measured, and LVCO and RVCO calculated.  These were normalized using nonlinear regression to estimated fetal weight (EFW) to provide means and standard deviations. Among FDMs, mean Z-scores and 95% confidence limits (CL) were calculated, and compared to zero. LVCO, RVCO, and parameters they were calculated from, increased predictably and non-linearly with increasing EFW.  In FDM, LVCO was depressed (mean Z -1.679, 95% CL -2.404, -0.955, pFDM have significantly lower right and left heart stroke volumes and outputs for weight than do normal fetuses. © 2018 The authors.

  16. Femoral Blood Flow and Cardiac Output During Blood Flow Restricted Leg Press Exercise

    Science.gov (United States)

    Everett, M. E.; Hackney, K.; Ploutz-Snyder, L.

    2011-01-01

    Low load blood flow restricted resistance exercise (LBFR) causes muscle hypertrophy that may be stimulated by the local ischemic environment created by the cuff pressure. However, local blood flow (BF) during such exercise is not well understood. PURPOSE: To characterize femoral artery BF and cardiac output (CO) during leg press exercise (LP) performed at a high load (HL) and low load (LL) with different levels of cuff pressure. METHODS: Eleven subjects (men/women 4/7, age 31.4+/-12.8 y, weight 68.9+/-13.2 kg, mean+/-SD) performed 3 sets of supine left LP to fatigue with 90 s of rest in 4 conditions: HL (%1-RM/cuff pressure: 80%/0); LL (20%/0); LBFR(sub DBP) (20%/1.3 x diastolic blood pressure, BP); LBFR(sub SBP) (20%/1.3 x supine systolic BP). The cuff remained inflated throughout the LBFR exercise sessions. Artery diameter, velocity time integral (VTI), and stroke volume (SV) were measured using Doppler ultrasound at rest and immediately after each set of exercise. Heart rate (HR) was monitored using a 3-lead ECG. BF was calculated as VTI x vessel cross-sectional area. CO was calculated as HR x SV. The data obtained after each set of exercise were averaged and used for analyses. Multi-level modeling was used to determine the effect of exercise condition on dependent variables. Statistical significance was set a priori at p LL (9.92+/-0.82 cm3) > LBFR(sub dBP)(6.47+/-0.79 cm3) > LBFR(sub SBP) (3.51+/-0.59 cm3). Blunted exercise induced increases occurred in HR, SV, and CO after LBFR compared to HL and LL. HR increased 45% after HL and LL and 28% after LBFR (p<0.05), but SV increased (p<0.05) only after HL. Consequently, the increase (p<0.05) in CO was greater in HL and LL (approximately 3 L/min) than in LBFR (approximately 1 L/min). CONCLUSION: BF during LBFR(sub SBP) was 1/3 of that observed in LL, which supports the hypothesis that local ischemia stimulates the LBFR hypertrophic response. As the cuff did not compress the artery, the ischemia may have occurred

  17. Comparison of multiple non-invasive methods of measuring cardiac output during pregnancy reveals marked heterogeneity in the magnitude of cardiac output change between women.

    Science.gov (United States)

    Petersen, John W; Liu, Jing; Chi, Yueh-Yun; Lingis, Melissa; Williams, R Stan; Rhoton-Vlasak, Alice; Segal, Mark S; Conrad, Kirk P

    2017-04-01

    Various non-invasive methods are available to measure cardiac output (CO) during pregnancy. We compared serial measures of CO using various methods to determine which provided the least variability. Ten patients with spontaneous pregnancy had estimation of CO at baseline prior to becoming pregnant and at the end of the first and third trimesters. Echocardiographic data were used to estimate CO using the Teichholz method, Simpson's biplane method, and the Doppler determined velocity time integral (VTI) method. In addition, a Bioz Dx device was used to estimate CO by impedance cardiography. CO estimated with the VTI method had the lowest beat-to-beat variability. CO estimated with the VTI method was higher than CO estimated with the 2D-Teichholz method and Simpson's method. The percent change in CO during pregnancy was similar for all echo methods (VTI, Teichholz, and Simpson's biplane). Baseline CO determined with impedance cardiography was higher than CO determined with the VTI method. However, change in CO during pregnancy was significantly lower when measured with impedance cardiography. There was marked heterogeneity in the degree of rise in CO during the first trimester (-3 to 55%). The wide variation in the gestational rise in CO was unexpected, and at least in part secondary to variable increase in heart rate. We recommend the use of the Doppler determined VTI method for the estimation of CO in pregnancy. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  18. The Unpredictable Effect of Changing Cardiac Output on Hypoxemia after Acute Pulmonary Thromboembolism

    Directory of Open Access Journals (Sweden)

    John Y. C. Tsang

    2008-01-01

    Full Text Available Previous studies reported that the degree of hypoxemia following acute pulmonary thromboembolism (APTE was highly variable and that its mechanism was mainly due to the creation of many high and low ventilation/perfusion (V/Q units, as a result of the heterogeneous regional blood flow (Q caused by embolic obstruction. We studied the effect of changing cardiac output (Q t on gas exchange after APTE in 5 embolized piglets (23 ± 3 Kg, using Dobutamine intermittently at approximately 20 μg/kg/min for 120 minutes. The distribution of ventilation (V and perfusion (Q at various times was mapped using fluorescent microspheres in 941 ± 60 lung regions. After APTE, increase in Q t by Dobutamine improved venous oxygen tension (PvO 2 but arterial PaO 2 did not change consistently. On the other hand, cluster analysis showed that the V/Q ratio of most lung regions was lowered due to increases in Q at the same time. We concluded that the effect of changing cardiac output on gas exchange following APTE was affected by the simultaneous and varying balance between the changing V/Q mismatch and the concomitantly changing PvO 2 , which might explain the unpredictability of PaO 2 in the clinical setting.

  19. Cardiac Monitoring in Patients with Syncope: Making that Elusive Diagnosis

    Science.gov (United States)

    Subbiah, Rajesh; Chia, Pow-Li; Gula, Lorne J.; Klein, George J.; Skanes, Allan C.; Yee, Raymond; Krahn, Andrew D.

    2013-01-01

    Elucidating the cause of syncope is often a diagnostic challenge. At present, there is a myriad of ambulatory cardiac monitoring modalities available for recording cardiac rhythm during spontaneous symptoms. We provide a comprehensive review of these devices and discuss strategies on how to reach the elusive diagnosis based on current evidencebased recommendations. PMID:23228074

  20. Pulse dye densitometry using indigo carmine is useful for cardiac output measurement, but not for circulating blood volume measurement.

    Science.gov (United States)

    Fujita, Y; Yamamoto, T; Fuse, M; Kobayashi, N; Takeda, S; Aoyagi, T

    2004-08-01

    We evaluated the validity of a newly developed pulse dye densitometer for indigo carmine for measuring cardiac output and circulating blood volume. Measurements of cardiac output and circulating blood volume were performed with the indigo carmine densitometer during normovolaemia, hypovolaemia and hypervolaemia in nine mongrel dogs under general anaesthesia. The validity was evaluated by comparison of the values of cardiac output and circulating blood volume obtained by the thermodilution technique and the 51Cr-labelled red blood cell method, respectively. We also examined indigo carmine removal by continuous veno-venous haemofiltration after indigo carmine injection. There was good agreement between dye densitometer- and thermodilution-derived cardiac output (r = 0.885, P dye-densitometer-derived circulating blood volume was greater than that of the 51Cr-labelled red blood cell method, and both values showed weak agreement (r = 0.587, P indigo carmine through continuous veno-venous haemofiltration was 0.34+/-0.06. These data indicate that indigo carmine densitometry is a reliable method for cardiac output determination, but it overestimates circulating blood volume, probably due to the transition of indigo carmine into the extravascular space in the systemic circulation.

  1. ECG patch monitors for assessment of cardiac rhythm abnormalities.

    Science.gov (United States)

    Lobodzinski, S Suave

    2013-01-01

    The primary goal of long-term monitoring is the improvement of diagnostic yield. Despite the clear utility of Holter monitoring in clinical cardiology, issues of relatively low diagnostic yield, cost and inconvenience have motivated the development of ultra-portable devices referred to as ECG patch monitors. Although the "gold standard" for assessing cardiac rhythm abnormalities remains a 12-lead Holter, there is an increasing interest in portable monitoring devices that provide the opportunity for evaluating cardiac rhythm in real-world environments such as the workplace or home. To facilitate patient acceptance these monitors underwent a radical miniaturization and redesign to include wireless communication, water proofing and a patch carrier for attaching devices directly to the skin. We review recent developments in the field of "patch" devices primarily designed for very long-term monitoring of cardiac arrhythmic events. As the body of supporting clinical validation data grows, these devices hold promise for a variety of cardiac monitoring applications. From a clinical and research standpoint, the capacity to obtain longitudinal cardiac activity data by patch devices may have significant implications for device selection, monitoring duration, and care pathways for arrhythmia evaluation and atrial fibrillation surveillance. From a research standpoint, the new devices may allow for the development of novel diagnostic algorithms with the goal of finding patterns and correlations with exercise and drug regimens. © 2013.

  2. Correlation of cardiac output and sevoflurane required to maintain anesthetic depth targeted with entropy index

    Directory of Open Access Journals (Sweden)

    Andrei E Bautin

    2014-01-01

    Full Text Available Aims and Objectives: We investigated the correlation of reduced cardiac output on required sevoflurane to maintain targeted anesthesia depth. Materials and Methods: 36 patients undergoing coronary artery bypass grafting with cardiopulmonary bypass were prospectively included in the study. Inspired sevoflurane concentration was adjusted to ensure state entropy index 2.2 l/min/m 2 (1.37% ± 0.31%, P = 0.01. Conclusion: Relationship between CI and ETsev required for maintaining target level of anesthesia is non-linear. Patients with CI ≤ 2.2 l/min/m 2 need lower levels of the ETsev for maintenance of the target anesthesia at an entropy index < 40.

  3. Effects of ventilation on cardiac output determined by inert gas rebreathing

    DEFF Research Database (Denmark)

    Damgaard, Morten; Norsk, Peter

    2005-01-01

    . Therefore, in 10 healthy males we investigated the effects of changes in ventilation pattern on cardiac output (CO) estimated by an N(2)O-rebreathing technique. Reducing the rebreathing volume (V(reb)) from 1.5 to 1.0 l diminished CO by 0.5 +/- 0.2 l min(-1), whereas an increase in V(reb) from 1.5 to 2.5 l...... breaths min(-1) or adding serial dead space by up to 600 ml did not affect the determination of CO. In conclusion, the rebreathing procedure for determination of CO at rest should be performed following a normal tidal expiration with a rebreathing bag volume of between 1.5 and 2.5 l and with manoeuvres...... separated by at least 3-5 min. Variations in RF within the physiological range from 15 to 30 breaths min(-1) do not affect outcome of the measurements....

  4. Non-invasive measurement of cardiac output by Finometer in patients with cirrhosis

    DEFF Research Database (Denmark)

    Kaltoft, N; Hobolth, L; Møller, S

    2010-01-01

    The Finometer measures haemodynamic parameters including cardiac output (CO) using non-invasive volume-clamp techniques. The aim of this study was to determine the accuracy of the Finometer in hyperdynamic cirrhotic patients using an invasive indicator dilution technique as control. CO was measured...... in twenty-three patients referred for invasive measurements of the hepatic venous pressure gradient on suspicion of cirrhosis. Invasive measurements of CO were performed using indicator dilution technique (CO(I)) and simultaneous measurements of CO were recorded with the Finometer (CO(F)). In six patients......, measurements of CO were performed with invasive technique and the Finometer both before and after beta-blockade using 80 mg of propranolol and the changes in CO (DeltaCO(I) and DeltaCO(F) respectively) were calculated to evaluate the Finometers ability to detect relative changes in CO. Mean CO(I) was 6.1 +/- 1...

  5. Phlebotomy eliminates the maximal cardiac output response to six weeks of exercise training

    DEFF Research Database (Denmark)

    Bonne, Thomas Christian; Doucende, Gregory; Flück, Daniela

    2014-01-01

    With this study we tested the hypothesis that six weeks of endurance training increases maximal cardiac output (Qmax) relatively more by elevating blood volume (BV) than by inducing structural and functional changes within the heart. Nine healthy but untrained volunteers (VO2max 47 ± 5 ml.min(-1......).kg(-1)) underwent supervised training (60 min; 4 times weekly at 65% VO2max for six weeks) and Qmax was determined by inert gas re-breathing during cycle ergometer exercise before and after the training period. After the training period, blood volume (determined in duplicates by CO re......-breathing) was re-established to pre-training values by phlebotomy and Qmax was quantified again. Resting echography revealed no structural heart adaptations as a consequence of the training intervention. Following the training period, plasma volume (PV), red blood cell volume (RBCV) and BV increased (p...

  6. Reference values for total blood volume and cardiac output in humans

    Energy Technology Data Exchange (ETDEWEB)

    Williams, L.R. [Indiana Univ., South Bend, IN (United States). Division of Liberal Arts and Sciences

    1994-09-01

    Much research has been devoted to measurement of total blood volume (TBV) and cardiac output (CO) in humans but not enough effort has been devoted to collection and reduction of results for the purpose of deriving typical or {open_quotes}reference{close_quotes} values. Identification of normal values for TBV and CO is needed not only for clinical evaluations but also for the development of biokinetic models for ultra-short-lived radionuclides used in nuclear medicine (Leggett and Williams 1989). The purpose of this report is to offer reference values for TBV and CO, along with estimates of the associated uncertainties that arise from intra- and inter-subject variation, errors in measurement techniques, and other sources. Reference values are derived for basal supine CO and TBV in reference adult humans, and differences associated with age, sex, body size, body position, exercise, and other circumstances are discussed.

  7. Left ventricular atrioventricular plane displacement is preserved with lifelong endurance training and is the main determinant of maximal cardiac output

    DEFF Research Database (Denmark)

    Steding-Ehrenborg, Katarina; Boushel, Robert C; Calbet, José A

    2015-01-01

    subjects (29 ± 4 years) underwent cardiac MR. All subjects underwent maximal exercise testing and for elderly subjects maximal cardiac output during cycling was determined using dye dilution technique. RESULTS: Longitudinal and radial contribution to stroke volume did not differ between groups......BACKGROUND: Age-related decline in cardiac function can be prevented or postponed by lifelong endurance training. However, effects of normal ageing as well as of lifelong endurance exercise on longitudinal and radial contribution to stroke volume are unknown. The aim of this study was to determine...... groups for RVAVPD (P = 0.2). LVAVPD was an independent predictor of maximal cardiac output (R(2 = ) 0.61, P groups. However, how longitudinal pumping...

  8. Effect of heat stress on cardiac output and systemic vascular conductance during simulated hemorrhage to presyncope in young men

    DEFF Research Database (Denmark)

    Ganio, Matthew S; Overgaard, Morten; Seifert, Thomas

    2012-01-01

    During moderate actual or simulated hemorrhage, as cardiac output decreases, reductions in systemic vascular conductance (SVC) maintain mean arterial pressure (MAP). Heat stress, however, compromises the control of MAP during simulated hemorrhage, and it remains unknown whether this response is due...... to a persistently high SVC and/or a low cardiac output. This study tested the hypothesis that an inadequate decrease in SVC is the primary contributing mechanism by which heat stress compromises blood pressure control during simulated hemorrhage. Simulated hemorrhage was imposed via lower body negative pressure...... (LBNP) to presyncope in 11 passively heat-stressed subjects (increase core temperature: 1.2 ± 0.2°C; means ± SD). Cardiac output was measured via thermodilution, and SVC was calculated while subjects were normothermic, heat stressed, and throughout subsequent LBNP. MAP was not changed by heat stress...

  9. Immediate changes in estimated cardiac output and vascular resistance after 60Co exposure in monkeys: implication for performance decrement

    International Nuclear Information System (INIS)

    Bruner, A.

    1977-01-01

    Aortic blood flow velocity, blood pressure, and heart rate were recorded in 12 unanesthetized, nonperforming monkeys during exposure to 1000 rad 60 Co at 129--164 rad/min. The first postradiation changes were seen within 3--4 min of the exposure's start and included tachycardia, a transient hypotension secondary to a loss in peripheral resistance, and a brief increase followed by a decrease to subnormal levels in cardiac output. The lowest cardiac output occurred between 10 and 20 min postexposure while blood pressure and peripheral resistance were recovering. It was proposed that the concurrent combination of low cardiac output, low blood pressure, and supranormal peripheral resistance might sufficiently attenuate cerebral perfusion temporarily to account for the transient behavioral decrements often seen during this time. Histamine release was postulated as responsible for this vascular shock syndrome

  10. Transit time dispersion in pulmonary and systemic circulation: effects of cardiac output and solute diffusivity.

    Science.gov (United States)

    Weiss, Michael; Krejcie, Tom C; Avram, Michael J

    2006-08-01

    We present an in vivo method for analyzing the distribution kinetics of physiological markers into their respective distribution volumes utilizing information provided by the relative dispersion of transit times. Arterial concentration-time curves of markers of the vascular space [indocyanine green (ICG)], extracellular fluid (inulin), and total body water (antipyrine) measured in awake dogs under control conditions and during phenylephrine or isoproterenol infusion were analyzed by a recirculatory model to estimate the relative dispersions of transit times across the systemic and pulmonary circulation. The transit time dispersion in the systemic circulation was used to calculate the whole body distribution clearance, and an interpretation is given in terms of a lumped organ model of blood-tissue exchange. As predicted by theory, this relative dispersion increased linearly with cardiac output, with a slope that was inversely related to solute diffusivity. The relative dispersion of the flow-limited indicator antipyrine exceeded that of ICG (as a measure of intravascular mixing) only slightly and was consistent with a diffusional equilibration time in the extravascular space of approximately 10 min, except during phenylephrine infusion, which led to an anomalously high relative dispersion. A change in cardiac output did not alter the heterogeneity of capillary transit times of ICG. The results support the view that the relative dispersions of transit times in the systemic and pulmonary circulation estimated from solute disposition data in vivo are useful measures of whole body distribution kinetics of indicators and endogenous substances. This is the first model that explains the effect of flow and capillary permeability on whole body distribution of solutes without assuming well-mixed compartments.

  11. Continuous versus bolus thermodilution cardiac output measurements--a comparative study.

    Science.gov (United States)

    Mihaljevic, T; von Segesser, L K; Tönz, M; Leskosek, B; Seifert, B; Jenni, R; Turina, M

    1995-05-01

    To compare the methods for continuous and bolus thermodilution cardiac output measurements. In vivo and in vitro experimental studies. Surgical research division in a university hospital. Eight calves and flow bench model. Data were collected in vivo from eight calves instrumented with pulmonary artery catheters, which allowed both continuous and bolus thermodilution measurements. The pulmonary artery catheter was placed through the external jugular vein. All in vitro measurements were performed using a flow bench model. A total of 232 bolus and continuous thermodilution measurements were analysed in vivo to determine the degree of agreement between the two methods. The absolute measurement bias was 0.14 L/min with 95% confidence limits ranging from -0.83 to 1.15 L/min. In vitro analysis of 576 measurements at six different temperature points (range 31 degrees to 41 degrees C), using clinically relevant flows (2 to 9 L/min), showed overestimation of flow values using continuous and bolus thermodilution methods. However, the continuous method showed better accuracy by a lower degree of overestimation. Systematic error was 9.7 +/- 8.4 (SD) % for continuous and 11.1 +/- 6.3% for the bolus method (p thermal filament of the pulmonary catheter impaired the accuracy of continuous measurement without affecting results from bolus measurements (systematic error -26.8 +/- 8.2% for continuous and -5.2 +/- 4.1% for bolus thermodilution). Continuous thermodilution cardiac output measurement provided higher accuracy and greater resistance to thermal noise than standard bolus measurements. The correct placement of the catheter is essential for precise measurements.

  12. Management of perioperative low cardiac output state without extracorporeal life support: What is feasible?

    Directory of Open Access Journals (Sweden)

    Kumar Girish

    2010-01-01

    Full Text Available A transient and reversible reduction in cardiac output-low cardiac output state (LCOS often occurs following surgery for congenital heart disease. Inappropriately managed LCOS is a risk factor for increased morbidity and death. LCOS may occasionally be progressive and refractory needing a period of "myocardial rest" with extracorporeal life support (ECLS. ECLS is currently considered a routine tool available for rapid deployment in most industrialized countries. Accumulated experience and refinements in technology have led to improving survivals - discharge survivals of 35%−50%, with almost 100% survival in select groups on elective left ventricular assist device. Thus, there is an increasing trend to initiate ECLS "early or electively in the operating room" in high-risk patients. India has a huge potential need for ECLS given the large number of infants presenting late with preexisting ventricular dysfunction or in circulatory collapse. ECLS is an expensive and resource consuming treatment modality and is not a viable therapeutic option in our country. The purpose of this paper is to reiterate an anticipatory, proactive approach to LCOS: (1 methods for early detection of evolving LCOS and (2 timely initiation of individualized therapy. This paper also explores what is feasible with the refinement of "simple, conventional, inexpensive strategies" for the management of LCOS. Therapy for LCOS should be multimodal based on the type of circulation and physiology. Our approach to LCOS includes: (1 intraoperative strategies, (2 aggressive afterload reduction, (3 lusitropy, (4 exclusion of structural defects, (5 harnessing cardiopulmonary interactions, and (6 addressing metabolic and endocrine abnormalities. We have achieved a discharge survival rate of greater than 97% with these simple methods.

  13. Risk factors for low cardiac output syndrome after coronary artery bypass grafting surgery.

    Science.gov (United States)

    Sá, Michel Pompeu Barros de Oliveira; Nogueira, Joana Rosa Costa; Ferraz, Paulo Ernando; Figueiredo, Omar Jacobina; Cavalcante, Wagner Cid Palmeira; Cavalcante, Thiago Cid Palmeira; Silva, Hugo Thiago Torres da; Santos, Cecília Andrade; Lima, Renato Oliveira de Albuquerque; Vasconcelos, Frederico Pires; Lima, Ricardo de Carvalho

    2012-01-01

    Low cardiac output syndrome (LCOS) is a serious complication after cardiac surgery and is associated with significant morbidity and mortality. The aim of this study is to identify risk factors for LCOS in patients undergoing coronary artery bypass grafting (CABG) in the Division of Cardiovascular Surgery of Pronto Socorro Cardiológico de Pernambuco - PROCAPE (Recife, PE, Brazil). A historical prospective study comprising 605 consecutive patients operated between May 2007 and December 2010. We evaluated 12 preoperative and 7 intraoperative variables. We applied univariate and multivariate logistic regression analysis. The incidence of LCOS was 14.7% (n = 89), with a lethality rate of 52.8% (n = 47). In multivariate analysis by logistic regression, four variables remained as independent risk factors: age > 60 years (OR 2.00, 95% CI 1.20 to 6.14, P = 0.009), on-pump CABG (OR 2.16, 95% CI 1.40 to 7.08, P = 0.006), emergency surgery (OR 4.71, 95% CI 1.34 to 26.55, P = 0.028), incomplete revascularization (OR 2.62, 95% CI 1.32 to 5.86, P = 0.003), and ejection fraction 60 years of off-pump CABG, emergency surgery, incomplete CABG and ejection fraction <50%.

  14. Accuracy of Cardiac Output by Nine Different Pulse Contour Algorithms in Cardiac Surgery Patients: A Comparison with Transpulmonary Thermodilution.

    Science.gov (United States)

    Broch, Ole; Bein, Berthold; Gruenewald, Matthias; Masing, Sarah; Huenges, Katharina; Haneya, Assad; Steinfath, Markus; Renner, Jochen

    2016-01-01

    Objective. Today, there exist several different pulse contour algorithms for calculation of cardiac output (CO). The aim of the present study was to compare the accuracy of nine different pulse contour algorithms with transpulmonary thermodilution before and after cardiopulmonary bypass (CPB). Methods. Thirty patients scheduled for elective coronary surgery were studied before and after CPB. A passive leg raising maneuver was also performed. Measurements included CO obtained by transpulmonary thermodilution (CO TPTD ) and by nine pulse contour algorithms (CO X1-9 ). Calibration of pulse contour algorithms was performed by esophageal Doppler ultrasound after induction of anesthesia and 15 min after CPB. Correlations, Bland-Altman analysis, four-quadrant, and polar analysis were also calculated. Results. There was only a poor correlation between CO TPTD and CO X1-9 during passive leg raising and in the period before and after CPB. Percentage error exceeded the required 30% limit. Four-quadrant and polar analysis revealed poor trending ability for most algorithms before and after CPB. The Liljestrand-Zander algorithm revealed the best reliability. Conclusions. Estimation of CO by nine different pulse contour algorithms revealed poor accuracy compared with transpulmonary thermodilution. Furthermore, the less-invasive algorithms showed an insufficient capability for trending hemodynamic changes before and after CPB. The Liljestrand-Zander algorithm demonstrated the highest reliability. This trial is registered with NCT02438228 (ClinicalTrials.gov).

  15. Transthoracic echocardiography: an accurate and precise method for estimating cardiac output in the critically ill patient.

    Science.gov (United States)

    Mercado, Pablo; Maizel, Julien; Beyls, Christophe; Titeca-Beauport, Dimitri; Joris, Magalie; Kontar, Loay; Riviere, Antoine; Bonef, Olivier; Soupison, Thierry; Tribouilloy, Christophe; de Cagny, Bertrand; Slama, Michel

    2017-06-09

    Cardiac output (CO) monitoring is a valuable tool for the diagnosis and management of critically ill patients. In the critical care setting, few studies have evaluated the level of agreement between CO estimated by transthoracic echocardiography (CO-TTE) and that measured by the reference method, pulmonary artery catheter (CO-PAC). The objective of the present study was to evaluate the precision and accuracy of CO-TTE relative to CO-PAC and the ability of transthoracic echocardiography to track variations in CO, in critically ill mechanically ventilated patients. Thirty-eight mechanically ventilated patients fitted with a PAC were included in a prospective observational study performed in a 16-bed university hospital ICU. CO-PAC was measured via intermittent thermodilution. Simultaneously, a second investigator used standard-view TTE to estimate CO-TTE as the product of stroke volume and the heart rate obtained during the measurement of the subaortic velocity time integral. Sixty-four pairs of CO-PAC and CO-TTE measurements were compared. The two measurements were significantly correlated (r = 0.95; p < 0.0001). The median bias was 0.2 L/min, the limits of agreement (LOAs) were -1.3 and 1.8 L/min, and the percentage error was 25%. The precision was 8% for CO-PAC and 9% for CO-TTE. Twenty-six pairs of ΔCO measurements were compared. There was a significant correlation between ΔCO-PAC and ΔCO-TTE (r = 0.92; p < 0.0001). The median bias was -0.1 L/min and the LOAs were -1.3 and +1.2 L/min. With a 15% exclusion zone, the four-quadrant plot had a concordance rate of 94%. With a 0.5 L/min exclusion zone, the polar plot had a mean polar angle of 1.0° and a percentage error LOAs of -26.8 to 28.8°. The concordance rate was 100% between 30 and -30°. When using CO-TTE to detect an increase in ΔCO-PAC of more than 10%, the area under the receiving operating characteristic curve (95% CI) was 0.82 (0.62-0.94) (p < 0.001). A ΔCO-TTE of more than 8

  16. High-Intensity Interval Training Increases Cardiac Output and V˙O2max.

    Science.gov (United States)

    Astorino, Todd A; Edmunds, Ross M; Clark, Amy; King, Leesa; Gallant, Rachael A; Namm, Samantha; Fischer, Anthony; Wood, Kimi M

    2017-02-01

    Increases in maximal oxygen uptake (V˙O2max) frequently occur with high-intensity interval training (HIIT), yet the specific adaptation explaining this result remains elusive. This study examined changes in V˙O2max and cardiac output (CO) in response to periodized HIIT. Thirty-nine active men and women (mean age and V˙O2max = 22.9 ± 5.4 yr and 39.6 ± 5.6 mL·kg·min) performed HIIT and 32 men and women (age and V˙O2max = 25.7 ± 4.5 yr and 40.7 ± 5.2 mL·kg·min) were nonexercising controls (CON). The first 10 sessions of HIIT required eight to ten 60 s bouts of cycling at 90%-110% percent peak power output interspersed with 75 s recovery, followed by randomization to one of three regimes (sprint interval training (SIT), high-volume interval training (HIITHI), or periodized interval training (PER) for the subsequent 10 sessions. Before, midway, and at the end of training, progressive cycling to exhaustion was completed during which V˙O2max and maximal CO were estimated. Compared with CON, significant (P training groups. Increases in V˙O2max exhibited in response to different HIIT regimes are due to improvements in oxygen delivery.

  17. Depressed left and right ventricular cardiac output in fetuses of diabetic mothers

    Directory of Open Access Journals (Sweden)

    Jennifer Winter MD

    2018-01-01

    Full Text Available Introduction: We compared right and left ventricular cardiac output (RVCO and LVCO in fetuses of diabetic mothers (FDM with a large normal cohort. Methods: We prospectively enrolled 264 normal fetuses and 30 FDM. Fetal CO parameters such as semilunar valve velocity time integrals (AVVTI, PVVTI, ventricular outflow diameters (LVOTD, RVOTD and stroke volumes (AVSV, PVSV were measured, and LVCO and RVCO were calculated. These were normalized using non-linear regression to estimated fetal weight (EFW to provide means and standard deviations. Among FDMs, mean Z scores and 95% confidence limits (CL were calculated and compared to zero. Results: LVCO, RVCO and parameters they were calculated from, increased predictably and non-linearly with increasing EFW. In FDM, LVCO was depressed (mean Z −1.679, 95% CL −2.404, −0.955, P < 0.001, and AVVTI, LVOTD and AVSV were significantly lower than normal. Similarly, RVCO (mean Z = −1.119, CL −1.839, −0.400, P = 0.003, RVOTD (mean −2.085, CL −3.077, −1.093, P < 0.001 and PVSV (mean −1.184, CL −1.921, −0.446, P = 0.003 were lower than normal, however, PVVTI was not different (mean Z 0.078, CL −0.552, +0.707, P = 0.803. Conclusion: Normal biventricular stroke volumes and outputs follow a non-linear regression with EFW. FDM have significantly lower right and left heart stroke volumes and outputs for weight than do normal fetuses.

  18. Impact of pacing modality and biventricular pacing on cardiac output and coronary conduit flow in the post-cardiotomy patient.

    LENUS (Irish Health Repository)

    Healy, David G

    2012-02-03

    We have previously demonstrated the role of univentricular pacing modalities in influencing coronary conduit flow in the immediate post-operative period in the cardiac surgery patient. We wanted to determine the mechanism of this improved coronary conduit and, in addition, to explore the possible benefits with biventricular pacing. Sixteen patients undergoing first time elective coronary artery bypass grafting who required pacing following surgery were recruited. Comparison of cardiac output and coronary conduit flow was performed between VVI and DDD pacing with a single right ventricular lead and biventricular pacing lead placement. Cardiac output was measured using arterial pulse waveform analysis while conduit flow was measured using ultrasonic transit time methodology. Cardiac output was greatest with DDD pacing using right ventricular lead placement only [DDD-univentricular 5.42 l (0.7), DDD-biventricular 5.33 l (0.8), VVI-univentricular 4.71 l (0.8), VVI-biventricular 4.68 l (0.6)]. DDD-univentricular pacing was significantly better than VVI-univentricular (P=0.023) and VVI-biventricular pacing (P=0.001) but there was no significant advantage to DDD-biventricular pacing (P=0.45). In relation to coronary conduit flow, DDD pacing again had the highest flow [DDD-univentricular 55 ml\\/min (24), DDD-biventricular 52 ml\\/min (25), VVI-univentricular 47 ml\\/min (23), VVI-biventricular 50 ml\\/min (26)]. DDD-univentricular pacing was significantly better than VVI-univentricular (P=0.006) pacing but not significantly different to VVI-biventricular pacing (P=0.109) or DDD-biventricular pacing (P=0.171). Pacing with a DDD modality offers the optimal coronary conduit flow by maximising cardiac output. Biventricular lead placement offered no significant benefit to coronary conduit flow or cardiac output.

  19. Individual differences in episodic memory abilities predict successful prospective memory output monitoring.

    Science.gov (United States)

    Hunter Ball, B; Pitães, Margarida; Brewer, Gene A

    2018-02-07

    Output monitoring refers to memory for one's previously completed actions. In the context of prospective memory (PM) (e.g., remembering to take medication), failures of output monitoring can result in repetitions and omissions of planned actions (e.g., over- or under-medication). To be successful in output monitoring paradigms, participants must flexibly control attention to detect PM cues as well as engage controlled retrieval of previous actions whenever a particular cue is encountered. The current study examined individual differences in output monitoring abilities in a group of younger adults differing in attention control (AC) and episodic memory (EM) abilities. The results showed that AC ability uniquely predicted successful cue detection on the first presentation, whereas EM ability uniquely predicted successful output monitoring on the second presentation. The current study highlights the importance of examining external correlates of PM abilities and contributes to the growing body of research on individual differences in PM.

  20. Monitoring cardiac stress using features extracted from S₁ heart sounds.

    Science.gov (United States)

    Herzig, Jonathan; Bickel, Amitai; Eitan, Arie; Intrator, Nathan

    2015-04-01

    It is known that acoustic heart sounds carry significant information about the mechanical activity of the heart. In this paper, we present a novel type of cardiac monitoring based on heart sound analysis. Specifically, we study two morphological features and their associations with physiological changes from the baseline state. The framework is demonstrated on recordings during laparoscopic surgeries of 15 patients. Insufflation, which is performed during laparoscopic surgery, provides a controlled, externally induced cardiac stress, enabling an analysis of each patient with respect to their own baseline. We demonstrate that the proposed features change during cardiac stress, and the change is more significant for patients with cardiac problems. Furthermore, we show that other well-known ECG morphology features are less sensitive in this specific cardiac stress experiment.

  1. Learning rules from multisource data for cardiac monitoring

    OpenAIRE

    Cordier, Marie-Odile; Fromont, Elisa; Quiniou, René

    2009-01-01

    http://www.springeronline.com/; This paper aims at formalizing the concept of learning rules from multisource data in a cardiac monitoring context. Our method has been implemented and evaluated on learning from data describing cardiac behaviors from different viewpoints, here electrocardiograms and arterial blood pressure measures. In order to cope with the dimensionality problems of multisource learning, we propose an Inductive Logic Programming method using a two-step strategy. Firstly, rul...

  2. Management of perioperative low cardiac output state without extracorporeal life support: What is feasible?

    International Nuclear Information System (INIS)

    Kumar, Girish; Iyer, Parvathi U

    2010-01-01

    A transient and reversible reduction in cardiac output–low cardiac output state (LCOS) often occurs following surgery for congenital heart disease. Inappropriately managed LCOS is a risk factor for increased morbidity and death. LCOS may occasionally be progressive and refractory needing a period of “myocardial rest” with extracorporeal life support (ECLS). ECLS is currently considered a routine tool available for rapid deployment in most industrialized countries. Accumulated experience and refinements in technology have led to improving survivals – discharge survivals of 35%–50%, with almost 100% survival in select groups on elective left ventricular assist device. Thus, there is an increasing trend to initiate ECLS “early or electively in the operating room” in high-risk patients. India has a huge potential need for ECLS given the large number of infants presenting late with preexisting ventricular dysfunction or in circulatory collapse. ECLS is an expensive and resource consuming treatment modality and is not a viable therapeutic option in our country. The purpose of this paper is to reiterate an anticipatory, proactive approach to LCOS: (1) methods for early detection of evolving LCOS and (2) timely initiation of individualized therapy. This paper also explores what is feasible with the refinement of “simple, conventional, inexpensive strategies” for the management of LCOS. Therapy for LCOS should be multimodal based on the type of circulation and physiology. Our approach to LCOS includes: (1) intraoperative strategies, (2) aggressive afterload reduction, (3) lusitropy, (4) exclusion of structural defects, (5) harnessing cardiopulmonary interactions, and (6) addressing metabolic and endocrine abnormalities. We have achieved a discharge survival rate of greater than 97% with these simple methods

  3. Evaluation of concordance among three cardiac output measurement techniques in adult patients during cardiovascular surgery postoperative care.

    Science.gov (United States)

    Muñoz, L; Velandia, A; Reyes, L E; Arevalo-Rodríguez, I; Mejía, C; Asprilla, D; Uribe, D V; Arevalo, J J

    2017-12-01

    The standard method for cardiac output measuring is thermodilution although it is an invasive technique. Transesophageal Echocardiography (TEE) offers a dynamic and functional alternative to thermodilution. Analyze concordance between two TEE methods and thermodilution for cardiac output assessment. Observational concordance study in cardiovascular surgery patients that required pulmonary artery catheter. TEE cardiac output measurement at both mitral annulus (MA) and left ventricle outflow tract (LVOT) were performed. Results were compared with thermodilution. Correlation was evaluated by Lin's concordance correlation coefficient and Bland-Altman analysis. Statistical analysis was undertaken in STATA 13.0. Twenty-five patients were enrolled. Fifty two percent of patients were male, median age and ejection fraction was 63 years and 35% respectively. Median thermodilution, LVOT and MA -measured cardiac output was 3.25 L/min, 3.46 L/min and 8.4 L/min respectively. Different values between thermodilution and MA measurements were found (Lin concordance=0.071; Confidence Interval 95%=-0.009 to 0.151; Spearman's correlation=0.22) as values between thermodilution and LVOT (Lin concordance=0.232; Confidence Interval 95%=-0.12 a 0.537; Spearman's correlation 0.28). Bland-Altman analysis showed greater difference between MA measurements and thermodilution (DM=-0.408; Bland-Altman Limits=-0.809 to -0.007), than the other echocardiographic findings (DM=0.007; Bland-Altman Limits=-0.441 to 0.428). Results from cardiac output measurement by doppler and 2D-TEE on both MA and LVOT do not correlate with those obtained by thermodilution. Copyright © 2017 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  4. Use of cardiac output to improve measurement of input function in quantitative dynamic contrast-enhanced MRI.

    Science.gov (United States)

    Zhang, Jeff L; Rusinek, Henry; Bokacheva, Louisa; Chen, Qun; Storey, Pippa; Lee, Vivian S

    2009-09-01

    To validate a new method for converting MR arterial signal intensity versus time curves to arterial input functions (AIFs). The method constrains AIF with patient's cardiac output (Q). Monte Carlo simulations of MR renography and tumor perfusion protocols were carried out for comparison with two alternative methods: direct measurement and population-averaged input function. MR renography was performed to assess the method's inter- and intraday reproducibility for renal parameters. In simulations of tumor perfusion, the precision of the parameters (K(trans) and v(e)) computed using the proposed method was improved by at least a factor of three compared to direct measurement. Similar improvements were obtained in simulations of MR renography. Volunteer study for testing interday reproducibility confirmed the improvement of precision in renal parameters when using the proposed method compared to conventional methods. In another patient study (two injections within one session), the proposed method significantly increased the correlation coefficient (R) between GFR of the two exams (0.92 vs. 0.83) compared to direct measurement. A new method significantly improves the precision of dynamic contrast-enhanced (DCE) parameters. The method may be especially useful for analyzing repeated DCE examinations, such as monitoring tumor therapy or angiotensin converting enzyme-inhibitor renography.

  5. [A dye densitometry analysis method for noninvasive measurement of cardiac output based on NIRS].

    Science.gov (United States)

    Lu, Meng-Meng; Wang, Hong-Xuan; Liu, Guang-Da; Xin, Gui-Jie; Yu, Yong; Zha, Yu-Tong

    2013-12-01

    Currently, there exist technology problems in cardiac output (CO) parameter detection clinically, such as invasive and complex operation, as well as possibility of infection and death for patients. In order to solve these problems, a noninvasive and continuous method based on NIRS for CO detection was presented. In this way, the concentration changing of indocyanine green (ICG) dye in the patient's arterial blood was dynamically measured and analyzed, so that the CO could be noninvasively and continuously measured according to the characteristic parameters of dye densitometry curve. While the ICG dye was injected into the patient's body by the median cubital vein, block of photoelectric pulse dye densitometry measurement system as the lower machine acquired pulse wave data and uploaded the data to upper computer. In the scheme, two specialized light sources of LED at 940 and 805 nm were used to capture the signals of sufferer's fingertip pulse wave synchronously and successively. The CO value could then be successfully calculated through drawing complete ICG concentration variation of dye dilution and excretion process and computing mean transmission time (MTT) by upper computer. Compared with the "gold standard" method of thermodilution, the maximum relative error of this method was below 9. 76%, and the mean relative error was below 4. 39%. The result indicates that the method can be used as a kind of convenient operation, noninvasive and continuous solution for clinical CO measurement.

  6. Distribution of cardiac output in dogs during intravenous infusion of betahistine.

    Science.gov (United States)

    Smith, K A; Meyer, M W

    1976-01-01

    Cardiac output (CO), arterial blood pressure (ABP), heart rate (HR), blood gases and blood flow (BF) to the brain, heart, kidney and skeletal muscles and other cephalic tissues in five dogs were studied before and at 30 minutes of betahistine infusion (0.12 to 0.2 mg per minute per kilogram). The particle distribution method using radioactive labeled 141Ce (15 mu) and 85Sr (15 mu) microspheres was utilized to quantitate and assess BF and CO. In the five dogs, the increase in CO averaged 20.8%, ABP remained constant, and HR increased in all but one exception where it decreased slightly concomitant with a decrease in Paco2. Brain BF increased (+ 29.6%) in the dogs whose Paco2 reamined constant. The BF increased to the heart (25.4%) and skeletal muslce (80%), while BF to the kidney and other tissues did not change. The change in HR appears to account for the change in CO. The dilating effect of betahistine on blood vessels, in the skeletal muscle, brain and heart could reduce peripheral resistance and decreace ABP. Thus, the increase in HR may be mediated through baroreceptor mechanisms rather than by a direct effect of betahistine. In addition, a decrease in Paco2, is more effective for decreasing cerebral BF than betahistine is for increasing blood flow.

  7. High Output Cardiac Failure Resolving after Repair of AV Fistula in a Six-Month-Old

    Directory of Open Access Journals (Sweden)

    Uygar Teomete

    2016-01-01

    Full Text Available Background. Acquired AVF in pediatrics are commonly caused by iatrogenic means, including arterial or venous punctures. These fistulae can cause great hemodynamic stress on the heart as soon as they are created. Case. A six-month-old 25-week gestation infant was referred for respiratory distress. Initial exam revealed tachypnea, tachycardia, and hypertension. There was a bruit noted on her left arm. An ultrasound showed an arteriovenous fistula. Its location, however, precluded intervention because of the high risk for limb-loss. An echocardiogram showed evidence of pulmonary hypertension that was treated with sildenafil and furosemide. However, no improvement was seen. On temporary manual occlusion of the fistula, the patient was noted to have increased her blood pressure and decreased her heart rate, suggesting significant hemodynamic effect of the fistula. The fistula was subsequently ligated and the patient clinically and echocardiographically improved. Conclusion. A patient in high output cardiac failure or pulmonary artery hypertension, especially prematüre patients with preexisting lung disease, should be probed for history of multiple punctures, trauma, or surgery and should have prompt evaluation for AVF. If it can be diagnosed and repaired, most of the cases have been shown to decrease the stress on the heart and reverse the pathologic hemodynamics.

  8. A computational model-based validation of Guyton's analysis of cardiac output and venous return curves

    Science.gov (United States)

    Mukkamala, R.; Cohen, R. J.; Mark, R. G.

    2002-01-01

    Guyton developed a popular approach for understanding the factors responsible for cardiac output (CO) regulation in which 1) the heart-lung unit and systemic circulation are independently characterized via CO and venous return (VR) curves, and 2) average CO and right atrial pressure (RAP) of the intact circulation are predicted by graphically intersecting the curves. However, this approach is virtually impossible to verify experimentally. We theoretically evaluated the approach with respect to a nonlinear, computational model of the pulsatile heart and circulation. We developed two sets of open circulation models to generate CO and VR curves, differing by the manner in which average RAP was varied. One set applied constant RAPs, while the other set applied pulsatile RAPs. Accurate prediction of intact, average CO and RAP was achieved only by intersecting the CO and VR curves generated with pulsatile RAPs because of the pulsatility and nonlinearity (e.g., systemic venous collapse) of the intact model. The CO and VR curves generated with pulsatile RAPs were also practically independent. This theoretical study therefore supports the validity of Guyton's graphical analysis.

  9. Cardiac output is not a significant source of low frequency mean arterial pressure variability

    International Nuclear Information System (INIS)

    Aletti, F; Baselli, G; Hammond, R L; Sala-Mercado, J A; O'Leary, D S; Chen, X; Mukkamala, R

    2013-01-01

    Spontaneous mean arterial pressure (MAP) variability may be mainly due to fluctuations in cardiac output (CO) and total peripheral resistance (TPR). While high frequency (HF ∼ 0.25 Hz) oscillations in MAP are ultimately driven by respiration, the source of low frequency (LF ∼ 0.1 Hz) fluctuations has not been fully elucidated. It is known that CO buffers these oscillations, but there is no evidence on its potential role in also generating them. The main goal was to determine whether CO is a source of LF variability in MAP. Six dogs were chronically instrumented to obtain beat-to-beat measurements of CO and MAP while the dogs were fully awake and at rest. A causal dynamic model was identified to relate the fluctuations in CO to MAP. The model was then used to predict the MAP fluctuations from the CO fluctuations. The CO fluctuations were able to predict about 70% of the MAP oscillations in the HF band but showed no predictive value in the LF band. Hence, respiration induces CO fluctuations in the HF band that, in turn, cause MAP oscillations, while TPR fluctuations appear to be the dominant mediator of LF fluctuations of MAP. CO is not a significant source of these oscillations, and it may only be responsible for dampening them, likely through the baroreflex. (paper)

  10. Agreement between ccNexfin CO-trek cardiac output and intermittent cold-bolus pulmonary thermodilution in a prospective multi-centre study

    NARCIS (Netherlands)

    Sperna Weiland, Nicolaas H.; de Wever, Jim W.; van Duivenvoorde, Yoni; Boer, Christa; Mitrev, Ludmil; Muntazar, Muhammad; Patel, Kinjal; Hollmann, Markus W.; Preckel, Benedikt

    2017-01-01

    The ccNexfin system uses the CO-trek algorithm to analyse a non-invasively obtained arterial pressure waveform and calculate cardiac output (NEXCO). It remains matter of debate whether NEXCO can replace invasive, pulmonary artery catheter derived, cold-bolus pulmonary thermodilution cardiac output

  11. Prevalence of nursing diagnosis of decreased cardiac output and the predictive value of defining characteristics in patients under evaluation for heart transplant

    OpenAIRE

    Matos, Lígia Neres; Guimarães, Tereza Cristina Felippe; Brandão, Marcos Antônio Gomes; Santoro, Deyse Conceição

    2012-01-01

    The purposes of the study were to identify the prevalence of defining characteristics (DC) of decreased cardiac output (DCO) in patients with cardiac insufficiency under evaluation for heart transplantation, and to ascertain the likelihood of defining characteristics being predictive factors for the existence of reduction in cardiac output. Data was obtained by retrospective documental analysis of the clinical records of right-sided heart catheterizations in 38 patients between 2004 and 2009....

  12. Assessment of interchangeability rate between 2 methods of measurements: An example with a cardiac output comparison study.

    Science.gov (United States)

    Lorne, Emmanuel; Diouf, Momar; de Wilde, Robert B P; Fischer, Marc-Olivier

    2018-02-01

    The Bland-Altman (BA) and percentage error (PE) methods have been previously described to assess the agreement between 2 methods of medical or laboratory measurements. This type of approach raises several problems: the BA methodology constitutes a subjective approach to interchangeability, whereas the PE approach does not take into account the distribution of values over a range. We describe a new methodology that defines an interchangeability rate between 2 methods of measurement and cutoff values that determine the range of interchangeable values. We used a simulated data and a previously published data set to demonstrate the concept of the method. The interchangeability rate of 5 different cardiac output (CO) pulse contour techniques (Wesseling method, LiDCO, PiCCO, Hemac method, and Modelflow) was calculated, in comparison with the reference pulmonary artery thermodilution CO using our new method. In our example, Modelflow with a good interchangeability rate of 93% and a cutoff value of 4.8 L min, was found to be interchangeable with the thermodilution method for >95% of measurements. Modelflow had a higher interchangeability rate compared to Hemac (93% vs 86%; P = .022) or other monitors (Wesseling cZ = 76%, LiDCO = 73%, and PiCCO = 62%; P < .0001). Simulated data and reanalysis of a data set comparing 5 CO monitors against thermodilution CO showed that, depending on the repeatability of the reference method, the interchangeability rate combined with a cutoff value could be used to define the range of values over which interchangeability remains acceptable.

  13. Children with Burn Injury Have Impaired Cardiac Output during Submaximal Exercise.

    Science.gov (United States)

    Rivas, Eric; Herndon, David N; Beck, Kenneth C; Suman, Oscar E

    2017-10-01

    Burn trauma damages resting cardiac function; however, it is currently unknown if the cardiovascular response to exercise is likewise impaired. We tested the hypothesis that, in children, burn injury lowers cardiac output (Q˙) and stroke volume (SV) during submaximal exercise. Five children with 49% ± 4% total body surface area (BSA) burned (two female, 11.7 ± 1 yr, 40.4 ± 18 kg, 141.1 ± 9 cm) and eight similar nonburned controls (five female, 12.5 ± 2 yr, 58.0 ± 17 kg, 147.3 ± 12 cm) with comparable exercise capacity (peak oxygen consumption [peak V˙O2]: 31.9 ± 11 vs 36.8 ± 8 mL O2·kg·min, P = 0.39) participated. The exercise protocol entailed a preexercise (pre-EX) rest period followed by 3-min exercise stages at 20 W and 50 W. V˙O2, HR, Q˙ (via nonrebreathing), SV (Q˙/HR), and arteriovenous O2 difference ([a-v]O2diff, Q˙/ V˙O2) were the primary outcome variables. Using a 2-way factorial ANOVA (group [G] × exercise [EX]), we found that Q˙ was approximately 27% lower in the burned than the nonburned group at 20 W of exercise (burned 5.7 ± 1.0 vs nonburned: 7.9 ± 1.8 L·min) and 50 W of exercise (burned 6.9 ± 1.6 vs nonburned 9.2 ± 3.2 L·min) (G-EX interaction, P = 0.012). SV did not change from rest to exercise in burned children but increased by approximately 24% in the nonburned group (main effect for EX, P = 0.046). Neither [a-v] O2diff nor V˙O2 differed between groups at rest or exercise, but HR response to exercise was reduced in the burn group (G-EX interaction, P = 0.004). When normalized to BSA, SV (index) was similar between groups; however, Q˙ (index) remained attenuated in the burned group (G-EX interaction, P exercise. Further investigation of hemodynamic function during exercise will provide insights important for cardiovascular rehabilitation in burned children.

  14. Validation of Peripherally Inserted Central Catheter-Derived Fick Cardiac Outputs in Patients with Heart Failure.

    Science.gov (United States)

    Tecson, Kristen M; Vasudevan, Anupama; Bindra, Amarinder; Joseph, Susan M; Felius, Joost; Hall, Shelley A; Kale, Parag

    2018-01-01

    The pulmonary artery catheter (PAC) remains the gold standard to calculate Fick cardiac outputs (FCOs) in patients with heart failure admitted to the intensive care unit (ICU). The peripherally inserted central catheter (PICC) provides long-term intravenous access and is used outside the ICU; however, there is scant literature validating venous oxygen saturations (VOSs) from PICC lines. Heart failure patients in the ICU with an existing PAC requiring a PICC line to transition were enrolled. Three blood samples were taken per person (1 at PICC, 1 at central venous pressure [CVP], and 1 at distal PAC). We performed repeated measures analysis of variance, as well as reliability analysis on 31 subjects (77% male, 71% Caucasian, mean ± standard deviation age 60 ± 8 years, 80% on inotropes). The average VOSs were 62 ± 11%, 62 ± 12%, and 61 ± 9% for the PICC line, CVP, and distal port, respectively (p = 0.66); there was excellent reliability (0.79). The median FCOs were 5 [4, 6], 5 [4, 6], and 5 [4, 6] L/min at the PICC, CVP, and distal port, respectively (p = 0.91); there was fair-to-good reliability (0.67). In conclusion, VOS and FCO did not differ by location, on average. Reliable data may be obtained through the PICC line, after evaluation from the PAC. The PICC may provide longer-term hemodynamic assessment while improving patient comfort. Copyright © 2017. Published by Elsevier Inc.

  15. Prevalence of lactic acidaemia in patients with advanced heart failure and depressed cardiac output.

    Science.gov (United States)

    Adamo, Luigi; Nassif, Michael E; Novak, Erik; LaRue, Shane J; Mann, Douglas L

    2017-08-01

    Heart failure (HF) has been defined classically as a condition in which the heart is unable to deliver sufficient oxygen to match the needs of the metabolizing tissues. Surprisingly, this definition has never been validated. The goal of this study was to determine the prevalence of elevated lactate levels in a cohort of patients with advanced heart failure. We retrospectively analysed the arterio-venous oxygen difference (A-V O 2 ), haemodynamics, and plasma lactate levels in stage D heart failure patients who were being evaluated for a left ventricular assist device (LVAD). We identified 359 patients with a right heart catheterization (RHC) performed prior to LVAD implantation. Plasma lactate was available for 96 patients. RHC showed that 93% of the patients had an A-V O 2 above the upper limit of normal (>5 mL/100 mL). Among patients with measured lactate levels, the prevalence of elevated lactate (>2.1 mmol/L) was 25% (95% confidence interval 16.7-34.9). The A-V O 2 was widened in all patients with elevated lactate, but plasma lactate did not correlate with A-V O 2 (r = 0.02) and only 27% of patients with increased A-V O 2 had elevated plasma lactate. Lactate levels were normal in ∼75% of the patients with advanced heart failure and a widened A-V O 2 , suggesting that the cardiac output was sufficient to meet the metabolic needs of the peripheral metabolizing tissues. Given that ∼4% of heart failure patients are in NYHA class IV, these findings suggest that the classic definition of heart failure pertains to ∼1% of patients with HF. © 2016 The Authors. European Journal of Heart Failure © 2016 European Society of Cardiology.

  16. Predictors of Post Pericardiotomy Low Cardiac Output Syndrome in Patients With Pericardial Effusion

    Directory of Open Access Journals (Sweden)

    Sabzi Feridoun

    2015-03-01

    Full Text Available Introduction: Pathological involvement of pericardium by any disease that resulting in effusion may require decompression and pericardiectomy. The current article describes rare patients with effusion who after pericadiectomy and transient hemodynamic improvement rapidly developed progressive heart failure and subsequent multi organ failure.Methods: During periods of five years, 423 patients in our hospital underwent pericardiotomy for decompression of effusion. The clinical characteristics of those patient with postoperative low cardiac output (B group (14 cases recorded and compared with other patients without this postoperative complication (A group by test and X2. Significant variables in invariables (P≤0.1 entered in logistic regression analysis and odd ratio of these significant variables obtained. Results: Idiopathic pericardial effusion, malignancy, renal failure, connective tissue disease, viral pericarditis was found in 125 patients (27%, 105 patients (25.4%, 65 patients (15.6%, 50 (17.1% and 10 (2.4% of patients subsequently. The factors that predict post-operative death in logistic regression analysis were malignancy, radiotherapy, constrictive pericarditis inotropic drug using IABP using, pre-operative EF and pericardial calcification.Conclusion: Certain preoperative variables such as malignancy, radiotherapy, low EF, calcified pericardium and connective tissue disease are associated with POLCOS and post-operative risk of death. This paradoxical response to pericardial decompression may be more frequent than currently appreciated. Its cause may relate to the sudden removal of the chronic external ventricular support from the effusion or thicken pericardium resulting in ventricular dilatation and failure or intra operative myocardial injury due to pericardiectomy of calcified pericardium, radiation and cardiomyopathy.

  17. Invasive hemodynamic monitoring in the postoperative period of cardiac surgery

    Directory of Open Access Journals (Sweden)

    Desanka Dragosavac

    1999-08-01

    Full Text Available OBJETIVE: To assess the hemodynamic profile of cardiac surgery patients with circulatory instability in the early postoperative period (POP. METHODS: Over a two-year period, 306 patients underwent cardiac surgery. Thirty had hemodynamic instability in the early POP and were monitored with the Swan-Ganz catheter. The following parameters were evaluated: cardiac index (CI, systemic and pulmonary vascular resistance, pulmonary shunt, central venous pressure (CVP, pulmonary capillary wedge pressure (PCWP, oxygen delivery and consumption, use of vasoactive drugs and of circulatory support. RESULTS: Twenty patients had low cardiac index (CI, and 10 had normal or high CI. Systemic vascular resistance was decreased in 11 patients. There was no correlation between oxygen delivery (DO2 and consumption (VO2, p=0.42, and no correlation between CVP and PCWP, p=0.065. Pulmonary vascular resistance was decreased in 15 patients and the pulmonary shunt was increased in 19. Two patients with CI < 2L/min/m² received circulatory support. CONCLUSION: Patients in the POP of cardiac surgery frequently have a mixed shock due to the systemic inflammatory response syndrome (SIRS. Therefore, invasive hemodynamic monitoring is useful in handling blood volume, choice of vasoactive drugs, and indication for circulatory support.

  18. Clinical review: Guyton - the role of mean circulatory filling pressure and right atrial pressure in controlling cardiac output

    OpenAIRE

    Henderson, William R; Griesdale, Donald EG; Walley, Keith R; Sheel, A William

    2010-01-01

    Arthur Guyton's concepts of the determinative role of right heart filling in cardiac output continue to be controversial. This paper reviews his seminal experiments in detail and clarifies the often confusing concepts underpinning his model. One primary criticism of Guyton's model is that the parameters describing venous return had not been measured in a functioning cardiovascular system in humans. Thus, concerns have been expressed in regard to the ability of Guyton's simplistic model, with ...

  19. Ambulatory Cardiac Monitoring for Discharged Emergency Department Patients with Possible Cardiac Arrhythmias

    Directory of Open Access Journals (Sweden)

    Donald Scheiber

    2014-03-01

    Full Text Available Introduction: Many emergency department (ED patients have symptoms that may be attributed to arrhythmias, necessitating outpatient ambulatory cardiac monitoring. Consensus is lacking on the optimal duration of monitoring. We describe the use of a novel device applied at ED discharge that provides continuous prolonged cardiac monitoring. Methods: We enrolled discharged adult ED patients with symptoms of possible cardiac arrhythmia. A novel, single use continuous recording patch (Zio®Patch was applied at ED discharge. Patients wore the device for up to 14 days or until they had symptoms to trigger an event. They then returned the device by mail for interpretation. Significant arrhythmias are defined as: ventricular tachycardia (VT ≥4 beats, supraventricular tachycardia (SVT ≥4 beats, atrial fibrillation, ≥3 second pause, 2nd degree Mobitz II, 3rd degree AV Block, or symptomatic bradycardia. Results: There were 174 patients were enrolled and all mailed back their devices. The average age was 52.2 (± 21.0 years, and 55% were female. The most common indications for device placement were palpitations 44.8%, syncope 24.1% and dizziness 6.3%. Eighty-three patients (47.7% had ≥1 arrhythmias and 17 (9.8% were symptomatic at the time of their arrhythmia. Median time to first arrhythmia was 1.0 days (IQR 0.2-2.8 and median time to first symptomatic arrhythmia was 1.5 days (IQR 0.4-6.7. 93 (53.4% of symptomatic patients did not have any arrhythmia during their triggered events. The overall diagnostic yield was 63.2% Conclusion: The Zio®Patch cardiac monitoring device can efficiently characterize symptomatic patients without significant arrhythmia and has a higher diagnostic yield for arrhythmias than traditional 24-48 hour Holter monitoring. It allows for longer term monitoring up to 14 days. [West J Emerg Med. 2014;15(2:194–198.

  20. Does obesity affect the non-invasive measurement of cardiac output performed by electrical cardiometry in children and adolescents?

    Science.gov (United States)

    Altamirano-Diaz, Luis; Welisch, Eva; Rauch, Ralf; Miller, Michael; Park, Teresa Sohee; Norozi, Kambiz

    2018-02-01

    Electrical cardiometry (EC) is a non-invasive and inexpensive method for hemodynamic assessment and monitoring. However, its feasibility for widespread clinical use, especially for the obese population, has yet to be determined. In this study, we evaluated the agreement and reliability of EC compared to transthoracic Doppler echocardiography (TTE) in normal, overweight, and obese children and adolescents. We measured stroke volume (SV) and cardiac output (CO) of 131 participants using EC and TTE simultaneously. We further divided these participants according to BMI percentiles for subanalyses: 95% obese (n = 83). Due to small sample size of the overweight group, we combined overweight and obese groups (OW+OB) with no significant change in results (SV and CO) before and after combining groups. There were strong correlations between EC and TTE measurements of SV (r = 0.869 and r = 0.846; p < 0.0001) and CO (r = 0.831 and r = 0.815; p < 0.0001) in normal and OW+OB groups, respectively. Bias and percentage error for CO measurements were 0.240 and 29.7%, and 0.042 and 29.5% in the normal and OW+OB groups, respectively. Indexed values for SV were lower in the OW+OB group than in the normal weight group when measured by EC (p < 0.0001) but no differences were seen when measured by TTE (p = 0.096). In all weight groups, there were strong correlations and good agreement between EC and TTE. However, EC may underestimate hemodynamic measurements in obese participants due to fat tissue.

  1. Endurance Training and V˙O2max: Role of Maximal Cardiac Output and Oxygen Extraction.

    Science.gov (United States)

    Montero, David; Diaz-Cañestro, Candela; Lundby, Carsten

    2015-10-01

    Although endurance training (ET) commonly augments maximal oxygen consumption (V˙O2max), it remains unclear whether such increase is associated with that of maximal cardiac output (Qmax) alone or along with arteriovenous oxygen difference (a-V˙O2diff). Herein, we sought to systematically review and determine the effects of ET on V˙O2max, Qmax, and a-V˙O2diff at maximal exercise, and on their associations, in healthy young subjects. We conducted a systematic search of MEDLINE, Scopus, and Web of Science (from their inception until September 2014) for articles assessing the effects of ET lasting ≥3 wk on V˙O2max and Qmax and/or a-V˙O2diff at maximal exercise in healthy young adults (mean age V˙O2max, Qmax, and a-V˙O2diff at maximal exercise between posttraining and pretraining measurements. Subgroup and meta-regression analyses were used to evaluate associations among SMD and potential moderating factors. Thirteen studies were included after systematic review, comprising a total of 130 untrained or moderately trained healthy young subjects (mean age, 22-28 yr). Duration of ET programs ranged from 5 to 12.9 wk. After data pooling, V˙O2max (SMD = 0.75, P P V˙O2diff at maximal exercise (SMD = 0.21, P = 0.23), were increased after ET. No significant heterogeneity was detected. With meta-regression, the SMD in Qmax was positively associated with the SMD in V˙O2max (B = 0.91, P = 0.007). The SMD in a-V˙O2diff at maximal exercise was not associated with the SMD in V˙O2max (B = 0.20, P = 0.40). Based on a relatively small number of studies, improvement in V˙O2max following 5-13 wk of ET is associated with increase in Qmax, but not in a-V˙O2diff, in previously untrained to moderately trained healthy young individuals.

  2. Usefulness of the Diagnosis "Decreased Cardiac Output (00029)" in Patients With Chronic Heart Failure.

    Science.gov (United States)

    Rojas Sánchez, Lyda Zoraya; Hernández Vargas, Juliana Alexandra; Trujillo Cáceres, Silvia Juliana; Roa Díaz, Zayne Milena; Jurado Arenales, Adriana Milena; Toloza Pérez, Yesith Guillermo

    2017-10-01

    To determine the clinical and construct validity of the nursing diagnosis "decreased cardiac output" (DCO) in patients with chronic heart failure. Cross-sectional study. A total of 200 people were studied. The defining characteristics with the highest prevalence were as follows: arrhythmia (62.5%) and fatigue (61.5%). Adjustment measures such as infit and outfit were maintained between 0.50 and 1.56 and the total variance explained by the measures was 29.3%. This study determined the clinical validity of the nursing diagnosis DCO. Regarding construct validity, adjustment of the defining characteristics to the Rasch model was observed. This study improves the evidence-based practice of nursing and strengthened the role of the nurse who leads care to this population. Determinar la validez clínica y de constructo del diagnóstico de enfermería "Disminución del Gasto Cardíaco" en pacientes con falla cardíaca crónica. MÉTODOS: Estudio de corte transversal. Un total de 200 pacientes fueron estudiados. Las características definitorias con las mayores prevalencias fueron: arritmia (62.5%) y fatiga (61.5%). Medidas de ajuste como el infit y outfit se mantuvieron entre 0.50 y 1.56. El total de la varianza explicada por las medidas fue de 29.3%. Este estudio determinó la validez clínica del diagnóstico de enfermería "Disminución del Gasto Cardíaco". En cuanto a la validez de constructo, se observó que 19 de las 21 características definitorias se ajustaron al modelo Rasch. IMPLICACIONES PARA LA PRÁCTICA DE ENFERMERÍA: Este estudio mejora la práctica basada en la evidencia de enfermería y fortalece el rol de las enfermeras que lideran el cuidado en esta población. © 2016 NANDA International, Inc.

  3. Effect of hemorrhage on cardiac output, vasopressin, aldosterone, and diuresis during immersion in men

    Science.gov (United States)

    Greenleaf, J. E.; Simanonok, K.; Bernauer, E. M.; Wade, C. E.; Keil, L. C.

    1992-01-01

    The purpose of this research was to test the hypotesis that a reduction in blood volume would attenuate or eliminate immersion-induced increases in cardiac output (Q(sub co)) and urine excretion, and to investigate accompanying vasoactive and fluid-electrolyte hormonal responses. Eight men (19-23 yr) were supine during a 2-hr control period in air, and then sat for 5-hr test periods in air at 20 C (dry control, DC); water at 34.5 C (wet control, WC); and water (34.5 C) after hemorrhage (WH) of 14.8 plus or minus 0.3 percent of their blood volume. Blood volume was -11.6 plus or minus 0.6 percent at immersion (time 0). Mean (bar-X hrs 1-5) Q(sub co) was unchanged in WC (5.3 plus or minus 0.01 l/min) and in WH (4.5 plus or minus 0.1 l/min), but decreased (P less than 0.05) in DC to 3.6 plus or minus 0.1 l/min. Mean urine excretion rates were 1.0 plus or minus 0.2 ml/min for DC and 1.1 plus or minus 0.2 ml/min for WH; both were lower (P less than 0.05) than that for WC of 2.0 plus or minus 0.4 ml/min. Plasma (Na+) and (Osm) were unchanged in all experiments. Mean plasma vasopressin (PVP) (bar-X hrs 1-5) was 1.1 plus or minus 0.1 pg/ml in WC, and higher (P less than 0.05) in DC (2.1 plus or minus 0.2 pg/ml)and WH (2.1 plus or minus 0.1 pg/ml); it was unchanged during air and water test periods. Thus, hemorrhage attenuated the immersion-induced increase in Q(sub co), eliminated the WC diuresis, maintained plasma renin activity and PVP at DC levels and did not change immersion-induced aldosterone suppression; the osmotic diuresis during control immersion is apparently not due to either aldosterone suppression or vasopressin suppression.

  4. Low cardiac output predicts development of hepatorenal syndrome and survival in patients with cirrhosis and ascites

    DEFF Research Database (Denmark)

    Krag, A; Bendtsen, F; Møller, S

    2010-01-01

    OBJECTIVES: Recent studies suggest that cardiac dysfunction precedes development of the hepatorenal syndrome. In this follow-up study, we aimed to investigate the relation between cardiac and renal function in patients with cirrhosis and ascites and the impact of cardiac systolic function...... (130 (SD 46) vs 78 (SD 29) mumol/l, phepatorenal syndrome type 1 within 3 months was higher in the group with low CI than in the high CI group (43% vs 5%, p = 0.04). Patients with the lowest CI (N = 8) had significantly poorer survival at 3, 9, and 12 months...

  5. Low cardiac output as physiological phenomenon in hibernating, free-ranging Scandinavian brown bears (Ursus arctos) - an observational study.

    Science.gov (United States)

    Jørgensen, Peter Godsk; Arnemo, Jon; Swenson, Jon E; Jensen, Jan S; Galatius, Søren; Frøbert, Ole

    2014-09-16

    Despite 5-7 months of physical inactivity during hibernation, brown bears (Ursus arctos) are able to cope with physiological conditions that would be detrimental to humans. During hibernation, the tissue metabolic demands fall to 25% of the active state. Our objective was to assess cardiac function associated with metabolic depression in the hibernating vs. active states in free-ranging Scandinavian brown bears. We performed echocardiography on seven free-ranging brown bears in Dalarna, Sweden, anesthetized with medetomidine-zolazepam-tiletamine-ketamine during winter hibernation in February 2013 and with medetomidine-zolazepam-tiletamine during active state in June 2013. We measured cardiac output noninvasively using estimates of hemodynamics obtained by pulsed wave Doppler echocardiography and 2D imaging. Comparisons were made using paired T-tests. During hibernation, all hemodynamic indices were significantly decreased (hibernating vs. active state): mean heart rate was 26.0 (standard deviation (SD): 5.6) beats per min vs. 75.0 (SD: 17.1) per min (P=0.002), mean stroke volume 32.3 (SD: 5.2) ml vs. 47.1 (SD: 7.9) ml (P=0.008), mean cardiac output 0.86 (SD: 0.31) l/min vs. 3.54 (SD: 1.04) l/min (P=0.003), and mean cardiac index 0.63 (SD: 0.21) l/min/kg vs. 2.45 (SD: 0.52) l/min/ m2 (Pbears during hibernation, despite the absence of atrial arrhythmias and valvular disease. Free-ranging brown bears demonstrate hemodynamics comparable to humans during active state, whereas during hibernation, we documented extremely low-flow hemodynamics. Understanding these physiological changes in bears may help to gain insight into the mechanisms of cardiogenic shock and heart failure in humans.

  6. The thick left ventricular wall of the giraffe heart normalises wall tension, but limits stroke volume and cardiac output.

    Science.gov (United States)

    Smerup, Morten; Damkjær, Mads; Brøndum, Emil; Baandrup, Ulrik T; Kristiansen, Steen Buus; Nygaard, Hans; Funder, Jonas; Aalkjær, Christian; Sauer, Cathrine; Buchanan, Rasmus; Bertelsen, Mads Frost; Østergaard, Kristine; Grøndahl, Carsten; Candy, Geoffrey; Hasenkam, J Michael; Secher, Niels H; Bie, Peter; Wang, Tobias

    2016-02-01

    Giraffes--the tallest extant animals on Earth--are renowned for their high central arterial blood pressure, which is necessary to secure brain perfusion. Arterial pressure may exceed 300 mmHg and has historically been attributed to an exceptionally large heart. Recently, this has been refuted by several studies demonstrating that the mass of giraffe heart is similar to that of other mammals when expressed relative to body mass. It thus remains unexplained how the normal-sized giraffe heart generates such massive arterial pressures. We hypothesized that giraffe hearts have a small intraventricular cavity and a relatively thick ventricular wall, allowing for generation of high arterial pressures at normal left ventricular wall tension. In nine anaesthetized giraffes (495±38 kg), we determined in vivo ventricular dimensions using echocardiography along with intraventricular and aortic pressures to calculate left ventricular wall stress. Cardiac output was also determined by inert gas rebreathing to provide an additional and independent estimate of stroke volume. Echocardiography and inert gas-rebreathing yielded similar cardiac outputs of 16.1±2.5 and 16.4±1.4 l min(-1), respectively. End-diastolic and end-systolic volumes were 521±61 ml and 228±42 ml, respectively, yielding an ejection fraction of 56±4% and a stroke volume of 0.59 ml kg(-1). Left ventricular circumferential wall stress was 7.83±1.76 kPa. We conclude that, relative to body mass, a small left ventricular cavity and a low stroke volume characterizes the giraffe heart. The adaptations result in typical mammalian left ventricular wall tensions, but produce a lowered cardiac output. © 2016. Published by The Company of Biologists Ltd.

  7. Significant correlation of comprehensive Aristotle score with total cardiac output during the early postoperative period after the Norwood procedure.

    Science.gov (United States)

    Li, Jia; Zhang, Gencheng; Holtby, Helen; Cai, Sally; Walsh, Mark; Caldarone, Christopher A; Van Arsdell, Glen S

    2008-07-01

    The comprehensive Aristotle score has been proposed as an individualized measure of the complexity of a given surgical procedure and has been reported to significantly correlate with postoperative morbidity and mortality after the Norwood procedure. An important factor leading to postoperative morbidity and mortality is low cardiac output. We studied the correlation between the comprehensive Aristotle score and cardiac output (CO) in infants after the Norwood procedure. Respiratory mass spectrometry was used to continuously measure systemic oxygen consumption (VO(2)) in 22 infants for 72 hours postoperatively. Arterial, superior vena caval and pulmonary venous blood gases were measured at 2 to 4 hour intervals to calculate CO. The comprehensive Aristotle score was collected. Hospital mortality was 4.5%. The comprehensive Aristotle score ranged from 14.5 to 23.5 and negatively correlated with CO (P = 0.027). Among the patient-adjusted factors, myocardial dysfunction (n = 10), mechanical ventilation to treat cardiorespiratory failure (n = 9) and atrioventricular valve regurgitation (n = 4) (P = 0.01) negatively correlated with CO (P = 0.06 to 0.07). Aortic atresia (n = 9) was associated with a lower CO (P = 0.01) for the first 24 hours which linearly increased overtime (P = 0.0001). No correlation was found between CO and other factors (P > 0.3 for all). Comprehensive Aristotle score significantly negatively correlates with CO after the Norwood procedure. A preoperative estimation of the comprehensive Aristotle score, particularly in association with myocardial dysfunction, mechanical ventilation to treat cardiorespiratory failure, atrioventricular valve regurgitation and aortic atresia may help to anticipate a high postoperative morbidity with low cardiac output syndrome.

  8. Clinical review: Guyton--the role of mean circulatory filling pressure and right atrial pressure in controlling cardiac output.

    Science.gov (United States)

    Henderson, William R; Griesdale, Donald E G; Walley, Keith R; Sheel, A William

    2010-01-01

    Arthur Guyton's concepts of the determinative role of right heart filling in cardiac output continue to be controversial. This paper reviews his seminal experiments in detail and clarifies the often confusing concepts underpinning his model. One primary criticism of Guyton's model is that the parameters describing venous return had not been measured in a functioning cardiovascular system in humans. Thus, concerns have been expressed in regard to the ability of Guyton's simplistic model, with few parameters, to model the complex human circulation. Further concerns have been raised in regard to the artificial experimental preparations that Guyton used. Recently reported measurements in humans support Guyton's theoretical and animal work.

  9. Correction of time resolution of an ambulatory cardiac monitor (VEST)

    International Nuclear Information System (INIS)

    Kumita, Shin-ichiro; Nishimura, Tsunehiko; Hayashida, Kohei; Uehara, Toshiisa

    1990-01-01

    Using ambulatory cardiac monitor (VEST) at exercise study, its time resolution is very important factor. We evaluated the time resolution of VEST using pulsate cardiac baloon phantom. Four analysis were carried out; no smoothing (NS) method, 3 points smoothing (3S) method, short sampling interval (SS) method, and digital filter (DF) method. By comparison of |ΔEF| (|EF:HR120-EF: HR60|) among 4 analysis methods, |ΔEF| by DF method was significant small (NS:3.58±3.01, 3S: 4.46±0.95, SS: 3.35±3.26, DF: 1.11±1.28%). We conclude that correction of time resolution by digital filter is necessary when we use VEST during exercise. (author)

  10. Accurate monitoring of blood loss: thoracic electrical impedance during hemorrhage in the pig

    DEFF Research Database (Denmark)

    Krantz, T.; Cai, Yan; Lauritzen, T.

    2000-01-01

    atrial natriuretic peptide, blood pressure, cardiac output, heart rate, hypovolemia, non-invasive monitoring, near infrared spectroscopy......atrial natriuretic peptide, blood pressure, cardiac output, heart rate, hypovolemia, non-invasive monitoring, near infrared spectroscopy...

  11. GASTO CARDÍACO MATERNO COMO PREDICTOR DEL SÍNDROME DE PREECLAMPSIA-ECLAMPSIA / Maternal cardiac output as a predictor of preeclampsia-eclampsia syndrome

    Directory of Open Access Journals (Sweden)

    Luis A. Díaz Moreno

    2012-03-01

    approximately 30% of systolic volume. The research objective was to predict the onset of preeclampsia-eclampsia syndrome by identifying alterations in cardiac output. Methods: An observational, descriptive, longitudinal, analytical study of prospective cohort was performed, in which by echocardiography, the cardiac output in 31 pregnant women between weeks 11 and 13.6 of gestation was determined as the only value, and through prenatal monitoring, the presence or absence of preeclampsia-eclampsia syndrome was observed. Results: The follow-up of 31 pregnant women was achieved, to whom cardiac output was measured, with the following findings: a prevalence of disease of 12.9% with 64.5% of patients correctly diagnosed, with a sensitivity of 75%, positive predictive value of 23%, specificity of 62% and negative predictive value of 94% with a relative risk of 4.1 (95% confidence interval, 0.48 to 35.6. Conclusions: It is possible to establish cardiac output measurement as screening study to predict the onset of preeclampsia syndrome from prenatal care, thus contributing to the decline in maternal death.

  12. Prevalence of nursing diagnosis of decreased cardiac output and the predictive value of defining characteristics in patients under evaluation for heart transplant.

    Science.gov (United States)

    Matos, Lígia Neres; Guimarães, Tereza Cristina Felippe; Brandão, Marcos Antônio Gomes; Santoro, Deyse Conceição

    2012-01-01

    The purposes of the study were to identify the prevalence of defining characteristics (DC) of decreased cardiac output (DCO) in patients with cardiac insufficiency under evaluation for heart transplantation, and to ascertain the likelihood of defining characteristics being predictive factors for the existence of reduction in cardiac output. Data was obtained by retrospective documental analysis of the clinical records of right-sided heart catheterizations in 38 patients between 2004 and 2009. The results showed that 71.1% of the patients had decreased cardiac output (measured by cardiac index). The majority of the NANDA-International defining characteristics for DCO were more frequent in individuals with reduced cardiac index levels. The study emphasizes the odds ratio (OR) for increased Systemic Vascular Resistance of OR=4.533, of the third heart sound with OR=3.429 and the reduced ejection fraction with OR=2.850. By obtaining the predictive values for the defining characteristics the study identifies them as diagnostic indicators of decreased cardiac output.

  13. Reduced peripheral arterial blood flow with preserved cardiac output during submaximal bicycle exercise in elderly heart failure

    Directory of Open Access Journals (Sweden)

    Leng Xiaoyan

    2009-11-01

    Full Text Available Abstract Background Older heart failure (HF patients exhibit exercise intolerance during activities of daily living. We hypothesized that reduced lower extremity blood flow (LBF due to reduced forward cardiac output would contribute to submaximal exercise intolerance in older HF patients. Methods and Results Twelve HF patients both with preserved and reduced left ventricular ejection fraction (LVEF (aged 68 ± 10 years without large (aorta or medium sized (iliac or femoral artery vessel atherosclerosis, and 13 age and gender matched healthy volunteers underwent a sophisticated battery of assessments including a peak exercise oxygen consumption (peak VO2, b physical function, c cardiovascular magnetic resonance (CMR submaximal exercise measures of aortic and femoral arterial blood flow, and d determination of thigh muscle area. Peak VO2 was reduced in HF subjects (14 ± 3 ml/kg/min compared to healthy elderly subjects (20 ± 6 ml/kg/min (p = 0.01. Four-meter walk speed was 1.35 ± 0.24 m/sec in healthy elderly verses 0.98 ± 0.15 m/sec in HF subjects (p p ≤ 0.03. Conclusion During CMR submaximal bike exercise in the elderly with heart failure, mechanisms other than low cardiac output are responsible for reduced lower extremity blood flow.

  14. The decrease of cardiac chamber volumes and output during positive-pressure ventilation

    DEFF Research Database (Denmark)

    Kristensen, Kasper Kyhl; Ahtarovski, Kiril Aleksov; Iversen, Kasper

    2013-01-01

    ) ml (P heart rate increased by 7 (±2) beats/min; and CO decreased by 1.0 (±0.4) l/min (P right and left ventricular peak filling rates decreased......Positive-pressure ventilation (PPV) is widely used for treatment of acute cardiorespiratory failure, occasionally at the expense of compromised cardiac function and arterial blood pressure. The explanation why has largely rested on interpretation of intracardiac pressure changes. We evaluated...

  15. Clinical usefulness of the definitions for defining characteristics of activity intolerance, excess fluid volume and decreased cardiac output in decompensated heart failure: a descriptive exploratory study.

    Science.gov (United States)

    de Souza, Vanessa; Zeitoun, Sandra Salloum; Lopes, Camila Takao; de Oliveira, Ana Paula Dias; Lopes, Juliana de Lima; de Barros, Alba Lucia Bottura Leite

    2015-09-01

    To assess the clinical usefulness of the operational definitions for the defining characteristics of the NANDA International nursing diagnoses, activity intolerance, decreased cardiac output and excess fluid volume, and the concomitant presence of those diagnoses in patients with decompensated heart failure. Content validity of the operational definitions for the defining characteristics of activity intolerance, excess fluid volume and decreased cardiac output have been previously validated by experts. Their clinical usefulness requires clinical validation. This was a descriptive exploratory study. Two expert nurses independently assessed 25 patients with decompensated heart failure for the presence or absence of 29 defining characteristics. Interrater reliability was analysed using the Kappa coefficient as a measure of clinical usefulness. The Fisher's exact test was used to test the association of the defining characteristics of activity intolerance and excess fluid volume in the presence of decreased cardiac output, and the correlation between the three diagnoses. Assessments regarding the presence of all defining characteristics reached 100% agreement, except with anxiety. Five defining characteristics of excess fluid volume were significantly associated with the presence of decreased cardiac output. Concomitant presence of the three diagnoses occurred in 80% of the patients. However, there was no significant correlation between the three diagnoses. The operational definitions for the diagnoses had strong interrater reliability, therefore they were considered clinically useful. Only five defining characteristics were representative of the association between excess fluid volume and decreased cardiac output. Therefore, excess fluid volume is related to decreased cardiac output, although these diagnoses are not necessarily associated with activity intolerance. The operational definitions may favour early recognition of the sequence of responses to decompensation

  16. Arterial pressure-based cardiac output in septic patients: different accuracy of pulse contour and uncalibrated pressure waveform devices.

    Science.gov (United States)

    Monnet, Xavier; Anguel, Nadia; Naudin, Brice; Jabot, Julien; Richard, Christian; Teboul, Jean-Louis

    2010-01-01

    We compared the ability of two devices estimating cardiac output from arterial pressure-curve analysis to track the changes in cardiac output measured with transpulmonary thermodilution induced by volume expansion and norepinephrine in sepsis patients. In 80 patients with septic circulatory failure, we administered volume expansion (40 patients) or introduced/increased norepinephrine (40 patients). We measured the pulse contour-derived cardiac index (CI) provided by the PiCCO device (CIpc), the arterial pressure waveform-derived CI provided by the Vigileo device (CIpw), and the transpulmonary thermodilution CI (CItd) before and after therapeutic interventions. The changes in CIpc accurately tracked the changes in CItd induced by volume expansion (bias, -0.20 +/- 0.63 L/min/m2) as well as by norepinephrine (bias, -0.05 +/- 0.74 L/min/m2). The changes in CIpc accurately detected an increase in CItd >or= 15% induced by volume expansion and norepinephrine introduction/increase (area under ROC curves, 0.878 (0.736 to 0.960) and 0.924 (0.795 to 0.983), respectively; P or= 15% induced by volume expansion and norepinephrine introduction/increase (area under ROC curves, 0.564 (0.398 to 0.720) and 0.541 (0.377 to 0.700, respectively, both not significantly different from versus 0.500). The CIpc was reliable and accurate for assessing the CI changes induced by volume expansion and norepinephrine. By contrast, the CIpw poorly tracked the trends in CI induced by those therapeutic interventions.

  17. STEM promotion through museum exhibits on cardiac monitoring & cardiac rhythm management.

    Science.gov (United States)

    Countryman, Jordan D; Dow, Douglas E

    2014-01-01

    Formal education in science, technology, engineering and math (STEM) does not successfully engage all of the students who have potential to become skilled in STEM activities and careers. Museum exhibits may be able to reach and engage a broader range of the public. STEM Exhibits that are both understandable and capture the imagination of viewers may contribute toward increased interest in STEM activities. One such topic for such an exhibit could be cardiac pacemakers and cardioverter defibrillators that sustain life. Although museums have existed for centuries, the available types of exhibit designs has dramatically increased in recent decades due to innovations in technology. Science and technology museums have especially taken advantage of the progression of exhibit design to developed new ways to communicate to their viewers. These novel presentation tools allow museums to more effectively convey to and engage viewers. This paper examines the techniques employed by museums in exhibits and considers the practices of several museums with exhibits related to cardiac monitoring (CM) and cardiac rhythm management (CRM).

  18. Non-invasive in vivo measurement of cardiac output in C57BL/6 mice using high frequency transthoracic ultrasound: evaluation of gender and body weight effects.

    Science.gov (United States)

    Domínguez, Elisabet; Ruberte, Jesús; Ríos, José; Novellas, Rosa; Del Alamo, Maria Montserrat Rivera; Navarro, Marc; Espada, Yvonne

    2014-10-01

    Even though mice are being increasingly used as models for human cardiovascular diseases, non-invasive monitoring of cardiovascular parameters such as cardiac output (CO) in this species is challenging. In most cases, the effects of gender and body weight (BW) on these parameters have not been studied. The objective of this study was to provide normal reference values for CO in C57BL/6 mice, and to describe possible gender and/or BW associated differences between them. We used 30-MHz transthoracic Doppler ultrasound to measure hemodynamic parameters in the ascending aorta [heart rate (HR), stroke volume (SV), stroke index (SI), CO, and cardiac index (CI)] in ten anesthetized mice of either sex. No differences were found for HR, SV, and CO. Both SI and CI were statistically lower in males. However, after normalization for BW, these differences disappeared. These results suggest that if comparisons of cardiovascular parameters are to be made between male and female mice, values should be standardized for BW.

  19. An Interoperable System toward Cardiac Risk Stratification from ECG Monitoring

    Science.gov (United States)

    Mora-Jiménez, Inmaculada; Ramos-López, Javier; Quintanilla Fernández, Teresa; García-García, Antonio; Díez-Mazuela, Daniel; García-Alberola, Arcadi

    2018-01-01

    Many indices have been proposed for cardiovascular risk stratification from electrocardiogram signal processing, still with limited use in clinical practice. We created a system integrating the clinical definition of cardiac risk subdomains from ECGs and the use of diverse signal processing techniques. Three subdomains were defined from the joint analysis of the technical and clinical viewpoints. One subdomain was devoted to demographic and clinical data. The other two subdomains were intended to obtain widely defined risk indices from ECG monitoring: a simple-domain (heart rate turbulence (HRT)), and a complex-domain (heart rate variability (HRV)). Data provided by the three subdomains allowed for the generation of alerts with different intensity and nature, as well as for the grouping and scrutinization of patients according to the established processing and risk-thresholding criteria. The implemented system was tested by connecting data from real-world in-hospital electronic health records and ECG monitoring by considering standards for syntactic (HL7 messages) and semantic interoperability (archetypes based on CEN/ISO EN13606 and SNOMED-CT). The system was able to provide risk indices and to generate alerts in the health records to support decision-making. Overall, the system allows for the agile interaction of research and clinical practice in the Holter-ECG-based cardiac risk domain. PMID:29494497

  20. An Interoperable System toward Cardiac Risk Stratification from ECG Monitoring

    Directory of Open Access Journals (Sweden)

    Cristina Soguero-Ruiz

    2018-03-01

    Full Text Available Many indices have been proposed for cardiovascular risk stratification from electrocardiogram signal processing, still with limited use in clinical practice. We created a system integrating the clinical definition of cardiac risk subdomains from ECGs and the use of diverse signal processing techniques. Three subdomains were defined from the joint analysis of the technical and clinical viewpoints. One subdomain was devoted to demographic and clinical data. The other two subdomains were intended to obtain widely defined risk indices from ECG monitoring: a simple-domain (heart rate turbulence (HRT, and a complex-domain (heart rate variability (HRV. Data provided by the three subdomains allowed for the generation of alerts with different intensity and nature, as well as for the grouping and scrutinization of patients according to the established processing and risk-thresholding criteria. The implemented system was tested by connecting data from real-world in-hospital electronic health records and ECG monitoring by considering standards for syntactic (HL7 messages and semantic interoperability (archetypes based on CEN/ISO EN13606 and SNOMED-CT. The system was able to provide risk indices and to generate alerts in the health records to support decision-making. Overall, the system allows for the agile interaction of research and clinical practice in the Holter-ECG-based cardiac risk domain.

  1. Effects of levosimendan for low cardiac output syndrome in critically ill patients

    DEFF Research Database (Denmark)

    Koster, Geert; Wetterslev, Jørn; Gluud, Christian

    2015-01-01

    in the systematic review and 49 trials (6,688 patients) in the meta-analysis. One trial had low risk of bias and nine trials (2,490 patients) were considered lower risk of bias. Trials compared levosimendan with placebo, control interventions, and other inotropes. Pooling all trials including heterogenous...... populations was considered inappropriate. Pooled analysis of 30 trials including critically ill patients not having cardiac surgery showed an association between levosimendan and mortality (RR 0.83, TSA-adjusted 95 % CI 0.59-0.97), while trials with lower risk of bias showed no significant difference (RR 0...

  2. [Advances in the research of application of urine output monitoring in prevention and treatment of burn shock].

    Science.gov (United States)

    Zeng, Q L; Wang, Q M; Li, N; Luo, Q Z

    2018-01-20

    Fluid therapy is a crucial treatment for patients with extensive burn, which affects patients'prognosis directly. Accurate urine output measurement plays an irreplaceable role in guiding fluid resuscitation in clinic. As one of the best indexes in traditional burn resuscitation, urine output comprehensively reflects systemic circulation. However, it doesn't fully reflect all the specific chapters of microcirculation and systemic circulation and deficient cellular oxygen metabolism exactly. We need to use urine output combined with other shock parameters to ensure adequate fluid replacement. Currently, the most common way of urine output monitoring is manual measurement. The article reviews the application of urine output monitoring in guiding fluid resuscitation of burn shock.

  3. Monitoring the consistency of the dynalyser output via digital display unit and calculated practical peak voltage

    International Nuclear Information System (INIS)

    Wan Hazlinda Ismail; Muhammad Jamal Mohd Isa; Abdul Aziz Mohd Ramli; Shahrul Azlan Azizan

    2010-01-01

    This study was carried out to ensure the adequacy and accuracy of the Dynalyser Digital Display unit for measuring the true kVp from the invasive kVp meter unit during calibration of non-invasive kVp meters. An invasive high voltage divider (dynalyser) coupled to the x-ray system measures the true kilo voltage supplied to the x-ray tube. The kVp output measured was displayed via its digital display unit while its waveform was acquired using a calibrated oscilloscope. The waveform was used to calculate the Practical Peak Voltage (PPV) using the International Standard method adapted from IEC 61676 and treated as the true kVp value. The kVp output was measured at 9 points ranging between 40 kV-120 kV with interval steps of 10 kV and monitored every day. The test result was evaluated for variation of output, intrinsic error and limit of variation in compliance with the IEC standard. Results showed that kVp output measured by the display unit everyday is consistent with variations of not more than ±0.45 kV, intrinsic error of not more than ±0.009 kV and limits of variation of less than 1% which comply with the IEC standard requirement. The kVp output via digital display unit has a total uncertainty of not more than 2.8 kV (k=2) while the PPV output via oscilloscope has total uncertainty of not more than 0.75 kV (k=2). As a conclusion, the dynalyser digital display unit complies with standard requirement and can be used to measure the true kVp output during the calibration of non-invasive kVp meters. (author)

  4. Plasma volume expansion does not increase maximal cardiac output or VO2 max in lowlanders acclimatized to altitude

    DEFF Research Database (Denmark)

    Calbet, José A L; Rådegran, Göran; Boushel, Robert Christopher

    2004-01-01

    liter of 6% dextran 70 (BV = 6.32 +/- 0.34 liters). PV expansion had no effect on Qmax, maximal O2 consumption (VO2), and exercise capacity. Despite maximal systemic O2 transport being reduced 19% due to hemodilution after PV expansion, whole body VO2 was maintained by greater systemic O2 extraction (P...... VO2 during exercise regardless of PV. Pulmonary ventilation, gas exchange, and acid-base balance were essentially unaffected by PV expansion. Sea......With altitude acclimatization, blood hemoglobin concentration increases while plasma volume (PV) and maximal cardiac output (Qmax) decrease. This investigation aimed to determine whether reduction of Qmax at altitude is due to low circulating blood volume (BV). Eight Danish lowlanders (3 females, 5...

  5. Measurement of cardiac output during exercise in healthy, trained humans using lithium dilution and pulse contour analysis

    International Nuclear Information System (INIS)

    Elliott, Adrian D; Skowno, Justin; Prabhu, Mahesh; Ansley, Les

    2012-01-01

    The aim of this study was to evaluate the use of pulse contour analysis calibrated with lithium dilution in a single device (LiDCO™) for measurement of cardiac output (.Q) during exercise in healthy volunteers. We sought to; (a) compare pulse contour analysis (PulseCO) and lithium indicator dilution (LiDCO) for the measurement of .Q during exercise, and (b) assess the requirement for recalibration of PulseCO with LiDCO during exercise. Ten trained males performed multi-stage cycling exercise at intensities below and above ventilatory threshold before constant load maximal exercise to exhaustion. Uncalibrated PulseCO .Q (.Q raw ) was compared to that calibrated with lithium dilution at baseline (.Q baseline ), during submaximal exercise below (.Q low ) and above (.Q high ) ventilatory threshold, and at each exercise stage individually (.Q exercise ). There was a significant difference between .Q baseline and all other calibration methods during exercise, but not at rest. No significant differences were observed between other methods. Closest agreement with .Q exercise was observed for .Q high (bias ± limits of agreement: 4.8 ± 30.0%). The difference between .Q exercise and both .Q low and .Q raw was characterized by low bias (4–7%) and wide limits of agreement (>±40%). Calibration of pulse contour analysis with lithium dilution prior to exercise leads to a systematic overestimation of exercising cardiac output. A single calibration performed during exercise above the ventilatory threshold provided acceptable limits of agreement with an approach incorporating multiple calibrations throughout exercise. Pulse contour analysis may be used for .Q measurement during exercise providing the system is calibrated during exercise. (paper)

  6. [Pulse indicator continuous cardiac output measurement-guided treatment aids two pediatric patients with severe acute pancreatitis complicated with acute respiratory distress syndrome].

    Science.gov (United States)

    Yan, Weiyuan; Wang, Lijie

    2014-09-01

    To evaluate the clinical value of the pulse indicator continuous cardiac output (PiCCO) system in patients with severe acute pancreatitis (SAP) complicated with acute respiratory distress syndrome (ARDS). Two cases of SAP with ARDS were monitored using PiCCO during comprehensive management in the Pediatric Intensive Care Unit (PICU) of Shengjing Hospital, China Medical University. To guide fluid management, the cardiac index (CI) was measured to assess cardiac function, the global end-diastolic volume index (GEDVI) was used to evaluate cardiac preload, and the extravascular lung water index (EVLWI) was used to evaluate the pulmonary edema. Case 1 was diagnosed with type L2 acute lymphoblastic leukemia (intermediate risk) and received the sixth maintenance phases of chemotherapy this time. After a 1-week dosage of chemotherapeutic drugs (pegaspargase and mitoxantrone), he suffered SAP combined with ARDS. Except comprehensive treatment (life supporting, antibiotic, etc.) and applying continuous veno-venous hemodiafiltration (CVVHDF) to remove inflammatory mediators. PiCCO monitor was utilized to guide fluid management. During the early stage of PiCCO monitoring, the patient showed no significant manifestations of pulmonary edema in the bedside chest X-ray (bedside ultrasound showed left pleural effusion), and had an oxygenation index 223 mmHg (1 mmHg = 0.133 kPa), GEDVI 450 ml/m², and ELVWI 7 ml/kg. We increased cardiac output to increase tissue perfusion and dehydration speed of CVVHDF was set at 70 ml/h. Two hours later, GEDVI significantly increased to 600 ml/m² and ELVWI significantly increased to 10 ml/kg, the oxygenation index declined to 155 mmHg, the bedside chest X-ray showed a significant decrease of permeability (right lung) and PEEP was adjusted to 5 cmH₂O (1 cmH₂O = 0.098 kPa), indicating circulating overload. ARDS subsequently occurred, upon which the fluid infusion was halted, the dehydration rate of CVVHDF raised (adjusted to 100-200 ml/h). On

  7. Evaluation of noninvasive exercise cardiac output determination in chronic heart failure patients: a proposal of a new diagnostic and prognostic method.

    Science.gov (United States)

    Cattadori, Gaia; Salvioni, Elisabetta; Gondoni, Erica; Agostoni, Piergiuseppe

    2011-01-01

    Peak oxygen consumption (VO2) and various parameters of cardiopulmonary response to exercise are of important prognostic value in chronic heart failure patients. However, all the available parameters only indirectly reflect left-ventricular dysfunction and hemodynamic adaptation to an increased demand. Noninvasive assessment of cardiac output, especially during an incremental exercise test, would allow the direct measurement of cardiac reserve and may become the gold standard for prognostic evaluation of chronic heart failure patients.

  8. Engineered hybrid cardiac patches with multifunctional electronics for online monitoring and regulation of tissue function

    Science.gov (United States)

    Feiner, Ron; Engel, Leeya; Fleischer, Sharon; Malki, Maayan; Gal, Idan; Shapira, Assaf; Shacham-Diamand, Yosi; Dvir, Tal

    2016-01-01

    In cardiac tissue engineering approaches to treat myocardial infarction, cardiac cells are seeded within three-dimensional porous scaffolds to create functional cardiac patches. However, current cardiac patches do not allow for online monitoring and reporting of engineered-tissue performance, and do not interfere to deliver signals for patch activation or to enable its integration with the host. Here, we report an engineered cardiac patch that integrates cardiac cells with flexible, free-standing electronics and a 3D nanocomposite scaffold. The patch exhibited robust electronic properties, enabling the recording of cellular electrical activities and the on-demand provision of electrical stimulation for synchronizing cell contraction. We also show that electroactive polymers containing biological factors can be deposited on designated electrodes to release drugs in the patch microenvironment on-demand. We expect that the integration of complex electronics within cardiac patches will eventually provide therapeutic control and regulation of cardiac function. PMID:26974408

  9. Engineered hybrid cardiac patches with multifunctional electronics for online monitoring and regulation of tissue function

    Science.gov (United States)

    Feiner, Ron; Engel, Leeya; Fleischer, Sharon; Malki, Maayan; Gal, Idan; Shapira, Assaf; Shacham-Diamand, Yosi; Dvir, Tal

    2016-06-01

    In cardiac tissue engineering approaches to treat myocardial infarction, cardiac cells are seeded within three-dimensional porous scaffolds to create functional cardiac patches. However, current cardiac patches do not allow for online monitoring and reporting of engineered-tissue performance, and do not interfere to deliver signals for patch activation or to enable its integration with the host. Here, we report an engineered cardiac patch that integrates cardiac cells with flexible, freestanding electronics and a 3D nanocomposite scaffold. The patch exhibited robust electronic properties, enabling the recording of cellular electrical activities and the on-demand provision of electrical stimulation for synchronizing cell contraction. We also show that electroactive polymers containing biological factors can be deposited on designated electrodes to release drugs in the patch microenvironment on demand. We expect that the integration of complex electronics within cardiac patches will eventually provide therapeutic control and regulation of cardiac function.

  10. Noninvasive monitoring of cardiac allograft rejection by intramyocardial electrogram recordings.

    Science.gov (United States)

    Warnecke, H; Schüler, S; Goetze, H J; Matheis, G; Süthoff, U; Müller, J; Tietze, U; Hetzer, R

    1986-11-01

    Rejection after cardiac transplantation was monitored in nine patients by control of intramyocardial electrogram (IMEG) recordings transmitted by an implanted telemetric pacemaker. Under immunosuppression with cyclosporin A and prednisolone, 33 out of a total of 119 endomyocardial biopsy specimens showed moderate rejection (infiltrate with myocytolysis). Twenty-nine of these rejection episodes could be correctly predicted from IMEG recordings with a voltage drop above 15% used as a criterion (sensitivity 87.9%). Eighty-three of 86 negative biopsy results corresponded to negative IMEG results (specificity 96.5%). In this group of patients, amplitude of body surface electrocardiograms was not useful for the diagnosis of rejection because of the broad range of spontaneous variation. Control of IMEG voltage amplitude appears to be more accurate than body surface electrocardiogram amplitude in the detection of rejection episodes. Thus the onset of rejection during biopsy intervals is more readily detected and treatment is instituted earlier. The method is suitable for ambulatory patient monitoring by the patient's local physician.

  11. The Higher the Insulin Resistance the Lower the Cardiac Output in Men with Type 1 Diabetes During the Maximal Exercise Test.

    Science.gov (United States)

    Niedzwiecki, Pawel; Naskret, Dariusz; Pilacinski, Stanislaw; Pempera, Maciej; Uruska, Aleksandra; Adamska, Anna; Zozulinska-Ziolkiewicz, Dorota

    2017-06-01

    The aim of this study was to assess the hemodynamic parameters analyzed in bioimpedance cardiography during maximal exercise in patients with type 1 diabetes differing in insulin resistance. The study group consisted of 40 men with type 1 diabetes. Tissue sensitivity to insulin was assessed on the basis of the glucose disposal rate (GDR) analyzed during hyperinsulinemic-euglycemic clamp. Patients were divided into groups with GDR insulin sensitivity) and GDR ≥4.5 mg/kg/min (G2 group-higher insulin sensitivity). During the exercise test, the heart rate, systolic volume, cardiac output, cardiac index were measured by the impedance meter (PhysioFlow). Compared with the G2 group, the G1 group had a lower cardiac output (CO): during exercise 8.6 (IQR 7.7-10.0) versus 12.8 (IQR 10.8-13.7) L/min; P insulin resistance is associated with cardiac hemodynamic parameters assessed during and after exercise. The higher the insulin resistance the lower the cardiac output during maximal exercise in men with type 1 diabetes.

  12. Cardiac output measurement in ventilated lambs with a significant left-to-right shunt using the modified carbon dioxide fick method.

    NARCIS (Netherlands)

    Boode, W.P. de; Hopman, J.C.W.; Wijnen, M.H.W.A.; Tanke, R.B.; Hoeven, J.G. van der; Liem, K.D.

    2010-01-01

    BACKGROUND: It remains a great challenge to measure systemic blood flow in critically ill newborns. In a former study we validated the modified carbon dioxide Fick (mCO(2)F) method for measurement of cardiac output in a newborn lamb model. In this new study we studied the influence of a

  13. Continuous Glucose Monitoring in the Cardiac ICU: Current Use and Future Directions.

    Science.gov (United States)

    Scrimgeour, Laura A; Potz, Brittany A; Sellke, Frank W; Abid, M Ruhul

    2017-11-01

    Perioperative glucose control is highly important, particularly for patients undergoing cardiac surgery. Variable glucose levels before, during and after cardiac surgery lead to increased post-operative complications and patient mortality. [1] Current methods for intensive monitoring and treating hyperglycemia in the Intensive Care Unit (ICU) usually involve hourly glucose monitoring and continuous intravenous insulin infusions. With the advent of more accurate subcutaneous glucose monitoring systems, the role of improved glucose control with newer systems deserves consideration for widespread adoption.

  14. Cardiac output-based fluid optimization for kidney transplant recipients: a proof-of-concept trial.

    Science.gov (United States)

    Corbella, Davide; Toppin, Patrick Jason; Ghanekar, Anand; Ayach, Nour; Schiff, Jeffery; Van Rensburg, Adrian; McCluskey, Stuart A

    2018-04-10

    Intravenous fluid management for deceased donor kidney transplantation is an important, modifiable risk factor for delayed graft function (DGF). The primary objective of this study was to determine if goal-directed fluid therapy using esophageal Doppler monitoring (EDM) to optimize stroke volume (SV) would alter the amount of fluid given. This randomized, proof-of-concept trial enrolled 50 deceased donor renal transplant recipients. Data collected included patient characteristics, fluid administration, hemodynamics, and complications. The EDM was used to optimize SV in the EDM group. In the control group, fluid management followed the current standard of practice. The groups were compared for the primary outcome of total intraoperative fluid administered. There was no difference in the mean (standard deviation) volume of intraoperative fluid administered to the 24 control and 26 EDM patients [2,307 (750) mL vs 2,675 (842) mL, respectively; mean difference, 368 mL; 95% confidence interval (CI), - 87 to + 823; P = 0.11]. The incidence of complications in the control and EDM groups was similar (15/24 vs 17/26, respectively; P = 0.99), as was the incidence of delayed graft failure (8/24 vs 11/26, respectively; P = 0.36). Goal-directed fluid therapy did not alter the volume of fluid administered or the incidence of complications. This proof-of-concept trial provides needed data for conducting a larger trial to determine the influence of fluid therapy on the incidence in DGF in deceased donor kidney transplantation. www.clinicaltrials.gov (NCT02512731). Registered 31 July 2015.

  15. Test and Evaluation of the Zoll Medical Inc., PD2OOO Cardiac Monitor/Pacemaker/Defibrillator System

    National Research Council Canada - National Science Library

    Hade, Edward

    1997-01-01

    The Zoll PD2000 is a portable cardiac monitor, defibrillator and pacemaker that offers synchronized defibrillation, electrocardiogram monitoring, noninvasive temporary pacing and advisory capability...

  16. Changes in Total Cardiac Output and Oxygen Extraction During Exercise in Patients Supported With an HVAD Left Ventricular Assist Device.

    Science.gov (United States)

    Schmidt, Thomas; Bjarnason-Wehrens, Birna; Mommertz, Stephanie; Hannig, Meike; Schulte-Eistrup, Sebastian; Willemsen, Detlev; Reiss, Nils

    2018-02-12

    Following implantation of a left ventricular assist device (LVAD), acceptable functional performance is now being achieved; however, peak VO 2 and peak work load (watts) remain considerably limited. Maximum physical capacity is essentially dependent on generated cardiac output (CO) and arteriovenous oxygen difference (avDO 2 ). We investigated the changes in CO and avDO 2 during exercise in LVAD patients with an HVAD pump (HeartWare Inc., Framingham, MA, USA). Approximately 6 weeks after implantation, 20 patients (100% male, 60.8 ± 7.3 years old, BMI 25.7 ± 3.3) underwent a six-minute walk test (6MWT), a cardiopulmonary exercise test (CPET), and noninvasive hemodynamic measurement. The mean six-minute walking distance (6MWD) was 403 m (68% of predicted), and mean peak VO 2 was 10.9 mL/kg/min (39% of predicted). Mean total CO improved from 3.8 L at rest to 7.0 L at maximum exercise. The mean avDO 2 increased from 7.4 mL/dL (44% of oxygen content) at rest to 13.2 mL/dL (75% of oxygen content) at maximum exercise. There was a significant increase in both total CO (P parameters. © 2018 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  17. Corrective effect of diaphragm pacing on the decrease in cardiac output induced by positive pressure mechanical ventilation in anesthetized sheep.

    Science.gov (United States)

    Masmoudi, Hicham; Persichini, Romain; Cecchini, Jérôme; Delemazure, Julie; Dres, Martin; Mayaux, Julien; Demoule, Alexandre; Assouad, Jalal; Similowski, Thomas

    2017-02-01

    Positive pressure ventilation (PPV) is a fundamental life support measure, but it decreases cardiac output (CO). Diaphragmatic contractions produce negative intrathoracic and positive abdominal pressures, promoting splanchnic venous return. We hypothesized that: 1) diaphragm pacing alone could produce adequate ventilation without decreasing CO; 2) diaphragm pacing on top of PPV could improve CO. Of 11 anesthetized and mechanically ventilated ewes (39.6±5.9kg), 3 were discarded from analysis because of hemodynamic instability during the experiment, and 8 retained for analysis. Phrenic stimulation electrodes were inserted in the diaphragm (implanted phrenic nerve stimulation, iPS). CO was measured by the thermodilution technique (pulmonary artery catheter). CO during end-expiratory apnea served as reference. Median CO was 9.77 [6.25-11.25] lmin -1 during end-expiratory apnea, 8.25 [5.06-9.25] lmin -1 during "PPV" (-15%) (pventilation was comparable to its PPV counterpart (median 92% [74-97], NS). Diaphragm pacing alone can produce adequate ventilation without reducing CO. Superimposed onto PPV, diaphragm pacing can reduce the PPV-induced decrease in CO. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Diesel Exhaust Inhalation Increases Cardiac Output, Bradyarrhythmias, and Parasympathetic Tone in Aged Heart Failure-Prone Rats

    Science.gov (United States)

    Acute air pollutant inhalation is linked to adverse cardiac events and death, and hospitalizations for heart failure. Diesel exhaust (DE) is a major air pollutant suspected to exacerbate preexisting cardiac conditions, in part, through autonomic and electrophysiologic disturbance...

  19. Clinical validation of a real-time data processing system for cardiac output and arterial pressure measurement during intraoperative biventricular pacing optimization.

    Science.gov (United States)

    Johnson, Christopher K; Cabreriza, Santos E; Sahar, Rana L; Rusanov, Alexander; Wang, Daniel Y; Cheng, Bin; Gendy, Mira S; Quinn, T Alexander; Spotnitz, Henry Michael

    2012-01-01

    Biventricular pacing (BiVP) improves cardiac output (CO) and mean arterial pressure (MAP) after cardiopulmonary bypass (CPB) in selected patients at risk for acute left heart failure after cardiac surgery. Optimization of atrioventricular delay (AVD) and interventricular delay (VVD) to maximize the hemodynamic effect of pacing requires rapid and accurate data processing. Conventional post hoc data processing (PP) is accurate but time-consuming, and infeasible in the intraoperative setting. We created a customized, real-time data processing (RTP) system to improve data processing efficiency, while maintaining accuracy. Biventricular pacing optimization was performed within 1 hour of the conclusion of CPB in 10 patients enrolled in the Biventricular Pacing After Cardiac Surgery trial. Cardiac output, measured by an electromagnetic flow meter, and arterial pressure were recorded as AVD was randomly varied across seven settings and VVD across nine settings. Post hoc data processing values calculated by two observers were compared to RTP-generated outputs for CO and MAP. Interexaminer reliability coefficients were generated to access the dependability of RTP. Interexaminer reliability coefficient values ranged from 0.997 to 0.999, indicating RTP is as reliable as PP for optimization. Real-time data processing is instantaneous and therefore is more practical in a clinical setting than the PP method. Real-time data processing is useful for guiding intraoperative BiVP optimization and merits further development.

  20. Current and Emerging Uses of Insertable Cardiac Monitors: Evaluation of Syncope and Monitoring for Atrial Fibrillation.

    Science.gov (United States)

    Tomson, Todd T; Passman, Rod

    Insertable cardiac monitors (ICMs) have provided clinicians with a superb tool for assessing infrequent or potentially asymptomatic arrhythmias. ICMs have shown their usefulness in the evaluation of unexplained syncope, providing high diagnostic yields in a cost-effective manner. While unexplained syncope continues to be the most common reason for their use, ICMs are increasingly being used for the monitoring of atrial fibrillation (AF). Recent trials have demonstrated that a substantial proportion of patients with cryptogenic stroke have AF detected only by the prolonged monitoring provided by ICMs. A particularly promising and emerging use for ICMs is in the management of anticoagulation in patients with known paroxysmal AF. The introduction in recent years of ICMs with automatic AF detection algorithms and continuous remote monitoring in combination with novel oral anticoagulants have opened the door for targeted anticoagulation guided by remote monitoring, a strategy that has recently shown promise in pilot studies of this technique. While further research is needed before official recommendations can be given, this use of ICMs opens exciting new possibilities for personalized medicine that could potentially reduce bleeding risk and improve quality of life in patients with atrial fibrillation.

  1. Non-Contact Cardiac Activity Monitoring using Pulsed Laser Vibrometer

    Directory of Open Access Journals (Sweden)

    Chen Chia WANG

    2014-01-01

    Full Text Available We demonstrate experimentally the detection of detailed human cardiac mechanical activity in a remote, non-contacting, and non-ionizing manner using a pulsed laser vibrometer. The highly sensitive pulsed laser vibrometer allows the detection of the temporally-phased mechanical events occurring in individual cardiac cycles even from the surface of clothing-covered extremities of the subjects. Fine structures of the detected cardiac traces are identified with their meanings assigned and corroborated using accelerometer and electrocardiogram measurements obtained concurrently with the pulsed laser vibrometer studies.

  2. Inspiratory Muscle Training Is Associated With Improved Inspiratory Muscle Strength, Resting Cardiac Output, and the Ventilatory Efficiency of Exercise in Patients With a Fontan Circulation.

    Science.gov (United States)

    Laohachai, Karina; Winlaw, David; Selvadurai, Hiran; Gnanappa, Ganesh Kumar; d'Udekem, Yves; Celermajer, David; Ayer, Julian

    2017-08-21

    Patients with a Fontan circulation have reduced exercise capacity and respiratory muscle strength. Inspiratory muscle training (IMT) improves exercise capacity and quality of life in adults with heart failure. We assessed whether 6 weeks of a home-based program of IMT improves inspiratory muscle strength and the ventilatory efficiency of exercise in adolescent patients with a Fontan circulation. Twenty-three adolescent participants (aged 16±2 years) with a Fontan circulation underwent 6 weeks of IMT for 30 minutes daily. Respiratory muscle strength (maximal inspiratory pressure and expiratory pressure), lung function, and exercise capacity (cardiopulmonary exercise testing) were assessed. Fourteen of 23 participants also underwent exercise cardiac magnetic resonance imaging to examine the effects of IMT on cardiac output and systemic and pulmonary blood flow. Six weeks of IMT improved maximal inspiratory pressure by 36±24 cm H 2 O (61±46%) with no change in maximal expiratory pressure. Ventilatory efficiency of exercise improved after 6 weeks of IMT (from 34.2±7.8 to 32.2±5.6, P =0.04). In those who underwent exercise cardiac magnetic resonance imaging, IMT increased resting cardiac output (from 4.2±1.2 to 4.5±1.0 L/min, P =0.03) and ejection fraction (from 50.1±4.3 to 52.8±6.1%, P =0.03). Six weeks of IMT is associated with improved inspiratory muscle strength, ventilatory efficiency of exercise, and resting cardiac output in young Fontan patients. IMT may be a simple beneficial addition to the current management of Fontan patients, potentially reducing exercise intolerance and long-term morbidity and mortality. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  3. Monitor de eventos electrocardiacos implementado en plataforma PDA Monitor of cardiac events implemented in PDA platform

    Directory of Open Access Journals (Sweden)

    John Bustamante

    Full Text Available El monitoreo ambulatorio de eventos electrocardiacos es una herramienta valiosa en el diagnóstico de arritmias cardiacas, involucradas en procesos patológicos como miocardiopatías, estadios post-infarto, lesiones del sistema autónomo cardiaco, etc.; infortunadamente aún no es posible su uso extensivo debido a los altos costos que implica la adquisición de estos equipos. Con este propósito, se diseña y desarrolla mediante el uso de asistentes digitales personales, un monitor de eventos cardiacos con capacidad de grabación pre-sintomática y post-sintomática, visualización de señal electrocardiográfica en tiempo real, grabación automática de bradicardias y taquicardias, y posibilidad de anotación de síntomas por parte del paciente. Para ello se desarrolló un componente de hardware para la adquisición y tratamiento de las señales, un software para el monitoreo en plataforma Palm OS® y una aplicación para la descarga y análisis de los datos almacenados. Las validaciones del prototipo se realizaron mediante un simulador electrocardiográfico, un simulador de arritmias basado en registros de la base de datos de arritmias del Massachusetts Institute of Technology y Beth Israel Hospital, y pruebas piloto con personas sanas y pacientes con arritmias. En este reporte preliminar se enseña cómo el prototipo desarrollado, constituye una alternativa viable para el monitoreo ambulatorio de arritmias aprovechando las capacidades de almacenamiento, procesamiento y visualización con que cuentan los asistentes digitales actuales, con la ventaja adicional de que su uso no está restringido a una sola utilidad y su accesibilidad económica se facilita debido a su amplia disponibilidad comercial.Ambulatory monitoring of electro-cardiac events constitutes a valuable tool in the diagnosis of cardiac arrhythmias involved in pathologic processes such as myocardiopathies, post-infarction stages, autonomous cardiac system injuries, etc

  4. Long-Term Continuous Ambulatory ECG Monitors and External Cardiac Loop Recorders for Cardiac Arrhythmia: A Health Technology Assessment

    Science.gov (United States)

    Kabali, Conrad; Xie, Xuanqian; Higgins, Caroline

    2017-01-01

    Background Ambulatory electrocardiography (ECG) monitors are often used to detect cardiac arrhythmia. For patients with symptoms, an external cardiac loop recorder will often be recommended. The improved recording capacity of newer Holter monitors and similar devices, collectively known as longterm continuous ambulatory ECG monitors, suggests that they will perform just as well as, or better than, external loop recorders. This health technology assessment aimed to evaluate the effectiveness, cost-effectiveness, and budget impact of longterm continuous ECG monitors compared with external loop recorders in detecting symptoms of cardiac arrhythmia. Methods Based on our systematic search for studies published up to January 15, 2016, we did not identify any studies directly comparing the clinical effectiveness of longterm continuous ECG monitors and external loop recorders. Therefore, we conducted an indirect comparison, using a 24-hour Holter monitor as a common comparator. We used a meta-regression model to control for bias due to variation in device-wearing time and baseline syncope rate across studies. We conducted a similar systematic search for cost-utility and cost-effectiveness studies comparing the two types of devices; none were found. Finally, we used historical claims data (2006–2014) to estimate the future 5-year budget impact in Ontario, Canada, of continued public funding for both types of longterm ambulatory ECG monitors. Results Our clinical literature search yielded 7,815 non-duplicate citations, of which 12 cohort studies were eligible for indirect comparison. Seven studies assessed the effectiveness of longterm continuous monitors and five assessed external loop recorders. Both types of devices were more effective than a 24-hour Holter monitor, and we found no substantial difference between them in their ability to detect symptoms (risk difference 0.01; 95% confidence interval −0.18, 0.20). Using GRADE for network meta-analysis, we evaluated the

  5. Single-lead portable ECG devices: Perceptions and clinical accuracy compared to conventional cardiac monitoring.

    Science.gov (United States)

    Mehta, Devin D; Nazir, Noreen T; Trohman, Richard G; Volgman, Annabelle S

    2015-01-01

    Portable ECG devices are widely available yet there are limited data on their accuracy, physician and patient perceptions, and ease of use. The purpose of this study was to evaluate the accuracy of 4 single-lead portable ECG devices compared to a conventional 3-lead hospital cardiac monitor and to assess physician and patient perceptions of portable ECG devices. Twenty consecutive hospitalized patients were provided 4 portable ECG devices for 30 second cardiac rhythm recording. ECG rhythm strips from the portable ECG devices were interpreted by a group of 5 physician reviewers. The reviewers then compared the portable ECG device rhythm strips to simultaneously recorded hospital cardiac monitor rhythm strips to determine physician preference. A cardiac electrophysiologist interpreted ECG rhythm strips from the hospital cardiac monitor as the "gold standard." Rhythm interpretations of the portable ECG devices and the hospital cardiac monitor were analyzed to evaluate clinical accuracy. Patient perceptions were evaluated by a 20-item questionnaire. There was less than 50% concordance of portable ECG device rhythm strips with the hospital cardiac monitor (when uninterpretable rhythm strips were included). Physicians usually preferred interpreting ECGs from hospital cardiac monitors compared to portable ECG devices. Manufacturer instructions were insufficient to allow patients to operate portable ECG devices in a limited time. Most patients felt comfortable using a portable ECG device if prescribed by a physician. Portable ECG devices may be a reasonable option for long-term rhythm surveillance in select patients. Widespread use of these devices cannot be endorsed unless improvements in their accuracy are properly addressed. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Change in end-tidal carbon dioxide outperforms other surrogates for change in cardiac output during fluid challenge.

    Science.gov (United States)

    Lakhal, K; Nay, M A; Kamel, T; Lortat-Jacob, B; Ehrmann, S; Rozec, B; Boulain, T

    2017-03-01

    During fluid challenge, volume expansion (VE)-induced increase in cardiac output (Δ VE CO) is seldom measured. In patients with shock undergoing strictly controlled mechanical ventilation and receiving VE, we assessed minimally invasive surrogates for Δ VE CO (by transthoracic echocardiography): fluid-induced increases in end-tidal carbon dioxide (Δ VE E'CO2 ); pulse (Δ VE PP), systolic (Δ VE SBP), and mean systemic blood pressure (Δ VE MBP); and femoral artery Doppler flow (Δ VE FemFlow). In the absence of arrhythmia, fluid-induced decrease in heart rate (Δ VE HR) and in pulse pressure respiratory variation (Δ VE PPV) were also evaluated. Areas under the receiver operating characteristic curves (AUC ROC s) reflect the ability to identify a response to VE (Δ VE CO ≥15%). In 86 patients, Δ VE E'CO2 had an AUC ROC =0.82 [interquartile range 0.73-0.90], significantly higher than the AUC ROC for Δ VE PP, Δ VE SBP, Δ VE MBP, and Δ VE FemFlow (AUC ROC =0.61-0.65, all P  value of Δ VE E'CO2  >1 mm Hg (>0.13 kPa) had good positive (5.0 [2.6-9.8]) and fair negative (0.29 [0.2-0.5]) likelihood ratios. The 16 patients with arrhythmia had similar relationships between Δ VE E'CO2 and Δ VE CO to patients with regular rhythm ( r 2 =0.23 in both subgroups). In 60 patients with no arrhythmia, Δ VE E'CO2 (AUC ROC =0.84 [0.72-0.92]) outperformed Δ VE HR (AUC ROC =0.52 [0.39-0.66], P value of Δ VE E'CO2 >1 mm Hg (>0.13 kPa) indicated a likely response to VE. © The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  7. Reduced heart rate and cardiac output differentially affect angiogenesis, growth, and development in early chicken embryos (Gallus domesticus).

    Science.gov (United States)

    Branum, Sylvia R; Yamada-Fisher, Miho; Burggren, Warren

    2013-01-01

    An increase in both vascular circumferential tension and shear stress in the developing vasculature of the chicken embryo has been hypothesized to stimulate angiogenesis in the developing peripheral circulation chorioallantoic membrane (CAM). To test this hypothesis, angiogenesis in the CAM, development, and growth were measured in the early chicken embryo, following acute and chronic topical application of the purely bradycardic drug ZD7288. At hour 56, ZD7288 reduced heart rate (f(H)) by ~30% but had no significant effect on stroke volume (~0.19 ± 0.2 μL), collectively resulting in a significant fall in cardiac output (CO) from ~27 ± 3 to 18 ± 2 μL min(-1). Mean f(H) at 72 h of development was similarly significantly lowered by acute ZD7288 treatment (250 μM) to 128 ± 0.3 beats min(-1), compared with 174.5 ± 0.3 and 174.7 ± 0.8 beats min(-1) in control and Pannett-Compton (P-C) saline-treated embryos, respectively. Chronic dosing with ZD7288-and the attendant decreases in f(H) and CO-did not change eye diameter or cervical flexion (key indicators of development rate) at 120 h but significantly reduced overall growth (wet and dry body mass decreased by 20%). CAM vessel density index (reflecting angiogenesis) measured 200-400 μm from the umbilical stalk was not altered, but ZD7288 reduced vessel numbers-and therefore vessel density-by 13%-16% more distally (500-600 μm from umbilical stalk) in the CAM. In the ZD7288-treated embryos, a decrease in vessel length was found within the second branch order (~300-400 μm from the umbilical stock), while a decrease in vessel diameter was found closer to the umbilical stock, beginning in the first branch order (~200-300 μm). Paradoxically, chronic application of P-C saline also reduced peripheral CAM vessel density index at 500 and 600 μm by 13% and 7%, respectively, likely from washout of local angiogenic factors. In summary, decreased f(H) with reduced CO did not slow development rate but reduced embryonic

  8. Arrhythmias and Cardiac Bedside Monitoring in the Neonatal Intensive Care Unit.

    Science.gov (United States)

    McMullen, Sherri L

    2016-09-01

    Cardiac physiology is unique in neonates and infants; there are several physiologic changes that occur in the first weeks of life. Important changes can be captured on the bedside monitor and provide vital data in a noninvasive way to providers. The importance of diligent observation cannot be overstated. Bedside monitoring has improved in the last decade, which has enhanced the ability to detect changes in heart rates and rhythms. The purpose here is to review cardiac physiology, describe those arrhythmias able to be observed on bedside monitors, and highlight heart rate changes that can be early signs of sepsis. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Efficacy of medication directed by home-monitoring cardiac resynchronization therapy in chronic heart failure patients.

    Science.gov (United States)

    Yang, Hao; Zhang, Fei-fei; Peng, Xin-hui; Zhao, Dong-hua; Peng, Jian

    2014-03-01

    PATIENTS with chronic heart failure (CHF) have a high incidence of atrial/ventricular arrhythmias which seriously affect life span and quality of life. Cardiac re-synchronization therapy (CRT) can improve cardiac function and reverse myocardial remodeling, therefore improving the quality of life and reducing mortality. CRT with Home-Monitoring (HM) can be used to monitor cardiac arrhythmias and other heart physiological indexes such as intrathoracic impedance and hemodynamics. Through wireless satellites, the data from the patients are sent to a monitor center for analysis. Doctors can identify emergent information and make a rapid diagnosis based on the information stored in the monitor center. CRT with HM has been verified as a valid method to optimize drug treatment according to individual parameters.

  10. Treating cardiac arrhythmias detected with an implantable cardiac monitor in patients after an acute myocardial infarction

    DEFF Research Database (Denmark)

    Jøns, Christian; Thomsen, Poul Erik Bloch

    2012-01-01

    was the first to use the ICM in post-MI patients with moderate to severe left ventricular systolic dysfunction. Atrial fibrillation (AF) events lasting longer than 30 s were associated with an almost threefold increase in the risk of major cardiac events. This confirms the current definition of clinically......, and in the case of left ventricular dysfunction (LVEF ≤ 35%), an implantable cardioverter defibrillator/cardiac resynchronization therapy defibrillator (ICD/CRT-D) may be indicated. Nonsustained ventricular tachycardia (VT) is very frequent in post-MI patients, and in the CARISMA study, high-risk patients...... with nonsustained VT were implanted with an ICD. Furthermore, in 10% of the patients, the ICM recorded nonsustained VT episodes of ≥ 16 beats per minute, resulting in a twofold increase in the risk for cardiac death. Thus, patients with nonsustained VT should undergo careful investigation, and we recommend a repeat...

  11. Comparison of an Endotracheal Cardiac Output Monitor to a Pulmonary Artery Catheter

    Science.gov (United States)

    2017-12-04

    ile methods of fluid resuscitation remain controversial , maintenance of a patent airway and hemodynamic stabi lity as indicated by invasive...Edwards LifeSciences, Irvine, CA) pulmonary artery catheter (PAC) under hypothermic and hemorrhagic conditions. Methods Power analysis (G*Power...3.1) suggested 8 an imals would be sufficient for comparisons. After induction of anesthesia, instrumentation , and stabilization in experiment 1

  12. Prophylactic levosimendan for the prevention of low cardiac output syndrome and mortality in paediatric patients undergoing surgery for congenital heart disease.

    Science.gov (United States)

    Hummel, Johanna; Rücker, Gerta; Stiller, Brigitte

    2017-08-02

    Low cardiac output syndrome remains a serious complication, and accounts for substantial morbidity and mortality in the postoperative course of paediatric patients undergoing surgery for congenital heart disease. Standard prophylactic and therapeutic strategies for low cardiac output syndrome are based mainly on catecholamines, which are effective drugs, but have considerable side effects. Levosimendan, a calcium sensitiser, enhances the myocardial function by generating more energy-efficient myocardial contractility than achieved via adrenergic stimulation with catecholamines. Thus potentially, levosimendan is a beneficial alternative to standard medication for the prevention of low cardiac output syndrome in paediatric patients after open heart surgery. To review the efficacy and safety of the postoperative prophylactic use of levosimendan for the prevention of low cardiac output syndrome and mortality in paediatric patients undergoing surgery for congenital heart disease. We identified trials via systematic searches of CENTRAL, MEDLINE, Embase, and Web of Science, as well as clinical trial registries, in June 2016. Reference lists from primary studies and review articles were checked for additional references. We only included randomised controlled trials (RCT) in our analysis that compared prophylactic levosimendan with standard medication or placebo, in infants and children up to 18 years of age, who were undergoing surgery for congenital heart disease. Two review authors independently extracted data and assessed risk of bias according to a pre-defined protocol. We obtained additional information from all but one of the study authors of the included studies. We used the five GRADE considerations (study limitations, consistency of effect, imprecision, indirectness, and publication bias) to assess the quality of evidence from the studies that contributed data to the meta-analyses for the prespecified outcomes. We created a 'Summary of findings' table to

  13. A Cardiac Early Warning System with Multi Channel SCG and ECG Monitoring for Mobile Health

    Science.gov (United States)

    Sahoo, Prasan Kumar; Thakkar, Hiren Kumar; Lee, Ming-Yih

    2017-01-01

    Use of information and communication technology such as smart phone, smart watch, smart glass and portable health monitoring devices for healthcare services has made Mobile Health (mHealth) an emerging research area. Coronary Heart Disease (CHD) is considered as a leading cause of death world wide and an increasing number of people die prematurely due to CHD. Under such circumstances, there is a growing demand for a reliable cardiac monitoring system to catch the intermittent abnormalities and detect critical cardiac behaviors which lead to sudden death. Use of mobile devices to collect Electrocardiography (ECG), Seismocardiography (SCG) data and efficient analysis of those data can monitor a patient’s cardiac activities for early warning. This paper presents a novel cardiac data acquisition method and combined analysis of Electrocardiography (ECG) and multi channel Seismocardiography (SCG) data. An early warning system is implemented to monitor the cardiac activities of a person and accuracy assessment of the early warning system is conducted for the ECG data only. The assessment shows 88% accuracy and effectiveness of our proposed analysis, which implies the viability and applicability of the proposed early warning system. PMID:28353681

  14. Effects of reduced rebreathing time, in spontaneously breathing patients, on respiratory effort and accuracy in cardiac output measurement when using a partial carbon dioxide rebreathing technique: a prospective observational study

    OpenAIRE

    Tachibana, Kazuya; Imanaka, Hideaki; Takeuchi, Muneyuki; Nishida, Tomoyo; Takauchi, Yuji; Nishimura, Masaji

    2005-01-01

    Introduction New technology using partial carbon dioxide rebreathing has been developed to measure cardiac output. Because rebreathing increases respiratory effort, we investigated whether a newly developed system with 35 s rebreathing causes a lesser increase in respiratory effort under partial ventilatory support than does the conventional system with 50 s rebreathing. We also investigated whether the shorter rebreathing period affects the accuracy of cardiac output measurement. Method Once...

  15. Comparing the accuracy of ES-BC, EIS-GS, and ES Oxi on body composition, autonomic nervous system activity, and cardiac output to standardized assessments

    Directory of Open Access Journals (Sweden)

    Lewis JE

    2011-09-01

    Full Text Available John E Lewis1, Stacey L Tannenbaum1, Jinrun Gao3, Angelica B Melillo1, Evan G Long1, Yaima Alonso2, Janet Konefal1, Judi M Woolger2, Susanna Leonard1, Prabjot K Singh1, Lawrence Chen1, Eduard Tiozzo1 1Department of Psychiatry and Behavioral Sciences, 2Department of Medicine, University of Miami Miller School of Medicine, Miami, FL, 3State Farm Insurance, Bloomington, IL, USA Background and purpose: The Electro Sensor Complex (ESC is software that combines three devices using bioelectrical impedance, galvanic skin response, and spectrophotometry: (1 ES-BC (Electro Sensor-Body Composition; LD Technology, Miami, FL to assess body composition, (2 EIS-GS (Electro Interstitial Scan-Galvanic Skin; LD Technology to predict autonomic nervous system activity, and (3 ES Oxi (Electro Sensor Oxi; LD Technology to assess cardiac output. The objective of this study was to compare each to a standardized assessment: ES-BC to dual-energy X-ray absorptiometry (DXA, EIS-GS to heart rate variability, and ES Oxi to BioZ Dx Diagnostic System (BioZ Dx; SonoSite Inc, Bothell, WA. Patients and methods: The study was conducted in two waves. Fifty subjects were assessed for body composition and autonomic nervous system activity. Fifty-one subjects were assessed for cardiac output. Results: We found adequate relative and absolute agreement between ES-BC and DXA for fat mass (r = 0.97, P < 0.001 with ES-BC overestimating fat mass by 0.1 kg and for body fat percentage (r = 0.92, P < 0.001 with overestimation of fat percentage by 0.4%. For autonomic nervous system activity, we found marginal relative agreement between EIS-GS and heart rate variability by using EIS-GS as the predictor in a linear regression equation (adjusted R2 = 0.56, P = 0.03. For cardiac output, adequate relative and absolute agreement was found between ES Oxi and BioZ Dx at baseline (r = 0.60, P < 0.001, after the first exercise stage (r = 0.79, P < 0.001, and after the second exercise stage (r = 0.86, P

  16. Effect of Levosimendan on Low Cardiac Output Syndrome in Patients With Low Ejection Fraction Undergoing Coronary Artery Bypass Grafting With Cardiopulmonary Bypass: The LICORN Randomized Clinical Trial.

    Science.gov (United States)

    Cholley, Bernard; Caruba, Thibaut; Grosjean, Sandrine; Amour, Julien; Ouattara, Alexandre; Villacorta, Judith; Miguet, Bertrand; Guinet, Patrick; Lévy, François; Squara, Pierre; Aït Hamou, Nora; Carillion, Aude; Boyer, Julie; Boughenou, Marie-Fazia; Rosier, Sebastien; Robin, Emmanuel; Radutoiu, Mihail; Durand, Michel; Guidon, Catherine; Desebbe, Olivier; Charles-Nelson, Anaïs; Menasché, Philippe; Rozec, Bertrand; Girard, Claude; Fellahi, Jean-Luc; Pirracchio, Romain; Chatellier, Gilles

    2017-08-08

    Low cardiac output syndrome after cardiac surgery is associated with high morbidity and mortality in patients with impaired left ventricular function. To assess the ability of preoperative levosimendan to prevent postoperative low cardiac output syndrome. Randomized, double-blind, placebo-controlled trial conducted in 13 French cardiac surgical centers. Patients with a left ventricular ejection fraction less than or equal to 40% and scheduled for isolated or combined coronary artery bypass grafting with cardiopulmonary bypass were enrolled from June 2013 until May 2015 and followed during 6 months (last follow-up, November 30, 2015). Patients were assigned to a 24-hour infusion of levosimendan 0.1 µg/kg/min (n = 167) or placebo (n = 168) initiated after anesthetic induction. Composite end point reflecting low cardiac output syndrome with need for a catecholamine infusion 48 hours after study drug initiation, need for a left ventricular mechanical assist device or failure to wean from it at 96 hours after study drug initiation when the device was inserted preoperatively, or need for renal replacement therapy at any time postoperatively. It was hypothesized that levosimendan would reduce the incidence of this composite end point by 15% in comparison with placebo. Among 336 randomized patients (mean age, 68 years; 16% women), 333 completed the trial. The primary end point occurred in 87 patients (52%) in the levosimendan group and 101 patients (61%) in the placebo group (absolute risk difference taking into account center effect, -7% [95% CI, -17% to 3%]; P = .15). Predefined subgroup analyses found no interaction with ejection fraction less than 30%, type of surgery, and preoperative use of β-blockers, intra-aortic balloon pump, or catecholamines. The prevalence of hypotension (57% vs 48%), atrial fibrillation (50% vs 40%), and other adverse events did not significantly differ between levosimendan and placebo. Among patients with low ejection fraction

  17. Effect of Levosimendan on Low Cardiac Output Syndrome in Patients With Low Ejection Fraction Undergoing Coronary Artery Bypass Grafting With Cardiopulmonary Bypass

    Science.gov (United States)

    Caruba, Thibaut; Grosjean, Sandrine; Amour, Julien; Ouattara, Alexandre; Villacorta, Judith; Miguet, Bertrand; Guinet, Patrick; Lévy, François; Squara, Pierre; Aït Hamou, Nora; Carillon, Aude; Boyer, Julie; Boughenou, Marie-Fazia; Rosier, Sebastien; Robin, Emmanuel; Radutoiu, Mihail; Durand, Michel; Guidon, Catherine; Desebbe, Olivier; Charles-Nelson, Anaïs; Menasché, Philippe; Rozec, Bertrand; Girard, Claude; Fellahi, Jean-Luc; Pirracchio, Romain; Chatellier, Gilles

    2017-01-01

    Importance Low cardiac output syndrome after cardiac surgery is associated with high morbidity and mortality in patients with impaired left ventricular function. Objective To assess the ability of preoperative levosimendan to prevent postoperative low cardiac output syndrome. Design, Setting, and Participants Randomized, double-blind, placebo-controlled trial conducted in 13 French cardiac surgical centers. Patients with a left ventricular ejection fraction less than or equal to 40% and scheduled for isolated or combined coronary artery bypass grafting with cardiopulmonary bypass were enrolled from June 2013 until May 2015 and followed during 6 months (last follow-up, November 30, 2015). Interventions Patients were assigned to a 24-hour infusion of levosimendan 0.1 µg/kg/min (n = 167) or placebo (n = 168) initiated after anesthetic induction. Main Outcomes and Measures Composite end point reflecting low cardiac output syndrome with need for a catecholamine infusion 48 hours after study drug initiation, need for a left ventricular mechanical assist device or failure to wean from it at 96 hours after study drug initiation when the device was inserted preoperatively, or need for renal replacement therapy at any time postoperatively. It was hypothesized that levosimendan would reduce the incidence of this composite end point by 15% in comparison with placebo. Results Among 336 randomized patients (mean age, 68 years; 16% women), 333 completed the trial. The primary end point occurred in 87 patients (52%) in the levosimendan group and 101 patients (61%) in the placebo group (absolute risk difference taking into account center effect, −7% [95% CI, −17% to 3%]; P = .15). Predefined subgroup analyses found no interaction with ejection fraction less than 30%, type of surgery, and preoperative use of β-blockers, intra-aortic balloon pump, or catecholamines. The prevalence of hypotension (57% vs 48%), atrial fibrillation (50% vs 40%), and other adverse

  18. Accuracy of Intensity and Inclinometer Output of Three Activity Monitors for Identification of Sedentary Behavior and Light-Intensity Activity

    Directory of Open Access Journals (Sweden)

    Lucas J. Carr

    2012-01-01

    Full Text Available Purpose. To examine the accuracy of intensity and inclinometer output of three physical activity monitors during various sedentary and light-intensity activities. Methods. Thirty-six participants wore three physical activity monitors (ActiGraph GT1M, ActiGraph GT3X+, and StepWatch while completing sedentary (lying, sitting watching television, sitting using computer, and standing still light (walking 1.0 mph, pedaling 7.0 mph, pedaling 15.0 mph intensity activities under controlled settings. Accuracy for correctly categorizing intensity was assessed for each monitor and threshold. Accuracy of the GT3X+ inclinometer function (GT3X+Incl for correctly identifying anatomical position was also assessed. Percentage agreement between direct observation and the monitor recorded time spent in sedentary behavior and light intensity was examined. Results. All monitors using all thresholds accurately identified over 80% of sedentary behaviors and 60% of light-intensity walking time based on intensity output. The StepWatch was the most accurate in detecting pedaling time but unable to detect pedal workload. The GT3X+Incl accurately identified anatomical position during 70% of all activities but demonstrated limitations in discriminating between activities of differing intensity. Conclusions. Our findings suggest that all three monitors accurately measure most sedentary and light-intensity activities although choice of monitors should be based on study-specific needs.

  19. Test and Evaluation of the Hewlett-Packard CodeMaster 100 Cardiac Monitor/Pacemaker/Defibrillator System

    National Research Council Canada - National Science Library

    Hade, Edward

    1997-01-01

    The CodeMaster 100 is a portable cardiac monitor, defibrillator and pacemaker that offers synchronized defibrillation, electrocardiogram monitoring, noninvasive temporary pacing and pulse oximetery (SpO2) capabilities...

  20. Electrophysiological Monitoring of Brain Injury and Recovery after Cardiac Arrest

    Directory of Open Access Journals (Sweden)

    Ruoxian Deng

    2015-10-01

    Full Text Available Reliable prognostic methods for cerebral functional outcome of post cardiac-arrest (CA patients are necessary, especially since therapeutic hypothermia (TH as a standard treatment. Traditional neurophysiological prognostic indicators, such as clinical examination and chemical biomarkers, may result in indecisive outcome predictions and do not directly reflect neuronal activity, though they have remained the mainstay of clinical prognosis. The most recent advances in electrophysiological methods—electroencephalography (EEG pattern, evoked potential (EP and cellular electrophysiological measurement—were developed to complement these deficiencies, and will be examined in this review article. EEG pattern (reactivity and continuity provides real-time and accurate information for early-stage (particularly in the first 24 h hypoxic-ischemic (HI brain injury patients with high sensitivity. However, the signal is easily affected by external stimuli, thus the measurements of EP should be combined with EEG background to validate the predicted neurologic functional result. Cellular electrophysiology, such as multi-unit activity (MUA and local field potentials (LFP, has strong potential for improving prognostication and therapy by offering additional neurophysiologic information to understand the underlying mechanisms of therapeutic methods. Electrophysiology provides reliable and precise prognostication on both global and cellular levels secondary to cerebral injury in cardiac arrest patients treated with TH.

  1. A wearable healthcare system for cardiac signal monitoring using conductive textile electrodes.

    Science.gov (United States)

    Lim, Chae Young; Jang, Kuk Jin; Kim, Hyun-Woo; Kim, Young Hwan

    2013-01-01

    Accurate cardiac signal monitoring feasible for long-term monitoring is important for a practical, cost-effective health monitoring system. In this study, we propose a wearable healthcare system based on conductive fabric-based electrodes allowing monitoring of electrocardiogram (ECG) waveforms and demonstrated the potential for arrhythmia detection using the system. The measurement system uses conductive fabric-based electrodes arranged in a modified bipolar electrode configuration on the chest area of the patient. An adaptive impulse correlation filter (AICF) algorithm and a band pass filter to enable accurate R-peak detection in noisy environments.

  2. Effects of reduced rebreathing time, in spontaneously breathing patients, on respiratory effort and accuracy in cardiac output measurement when using a partial carbon dioxide rebreathing technique: a prospective observational study.

    Science.gov (United States)

    Tachibana, Kazuya; Imanaka, Hideaki; Takeuchi, Muneyuki; Nishida, Tomoyo; Takauchi, Yuji; Nishimura, Masaji

    2005-10-05

    New technology using partial carbon dioxide rebreathing has been developed to measure cardiac output. Because rebreathing increases respiratory effort, we investigated whether a newly developed system with 35 s rebreathing causes a lesser increase in respiratory effort under partial ventilatory support than does the conventional system with 50 s rebreathing. We also investigated whether the shorter rebreathing period affects the accuracy of cardiac output measurement. Once a total of 13 consecutive post-cardiac-surgery patients had recovered spontaneous breathing under pressure support ventilation, we applied a partial carbon dioxide rebreathing technique with rebreathing of 35 s and 50 s in a random order. We measured minute ventilation, and arterial and mixed venous carbon dioxide tension at the end of the normal breathing period and at the end of the rebreathing periods. We then measured cardiac output using the partial carbon dioxide rebreathing technique with the two rebreathing periods and using thermodilution. With both rebreathing systems, minute ventilation increased during rebreathing, as did arterial and mixed venous carbon dioxide tensions. The increases in minute ventilation and arterial carbon dioxide tension were less with 35 s rebreathing than with 50 s rebreathing. The cardiac output measures with both systems correlated acceptably with values obtained with thermodilution. When patients breathe spontaneously the partial carbon dioxide rebreathing technique increases minute ventilation and arterial carbon dioxide tension, but the effect is less with a shorter rebreathing period. The 35 s rebreathing period yielded cardiac output measurements similar in accuracy to those with 50 s rebreathing.

  3. A useful method to monitor outputs from a pulsed light source and its application to rate effect studies in a photomultiplier tube

    CERN Document Server

    Takeuchi, Y; Kurashige, H; Matono, Y; Murakami, K; Nomura, T; Sakamoto, H; Sasao, N; Suehiro, M; Fukushima, Y; Ikegami, Y; Nakamura, T T; Taniguchi, T; Asai, M

    1999-01-01

    In order to study short-term gain stability in a photomultiplier tube at high counting rate, we constructed an LED pulsed light source and its output monitoring system. For the monitoring system, we employed a photon counting method using a photomultiplier as a monitor photon detector. It is found that the method offers a simple way to monitor outputs from a pulsed light source and that, together with an LED light source, it provides a useful method to investigate photomultiplier's rate effects.

  4. Cerebral tissue oxygenation index, cardiac output and superior vena cava flow in infants with birth weight less than 1250 grams in the first 48 hours of life.

    Science.gov (United States)

    Sirc, J; Dempsey, E M; Miletin, J

    2013-07-01

    Near-infrared spectroscopy is a non-invasive method of assessing cerebral oxygenation. Functional echocardiography is increasingly used by neonatologists in the assessment of cardiovascular function. To correlate cerebral tissue oxygenation index (cTOI) and cardiac output in infants less than 1250 g at 6, 12, 24 and 48 hours of age. A prospective observational study. Newborns with birth weightoutputs, ductus arteriosus and cTOI were performed at 6, 12, 24 and 48 hours of age. Clinical parameters, including mean blood pressure, mean airway pressure, blood gas parameters and oxygen saturations were recorded. 22 neonates were enrolled following parental consent. The mean birth weight was 851 g (SD±201), mean gestational age was 25.9 weeks (SD±1.7). Mean SVC flow at 6 hours of age was 56.8 ml/kg/min and increased to 68.6 ml/kg/min at 48 hours of age. 9 infants (41%) had at least one measurement of low SVC flow (output increased during first 48 hours of life. cTOI decreased at 12 hours of age with a concomitant increase in fractionated oxygen extraction. These changes reflect transitional changes in both cardiac and cerebral hemodynamics in extremely low gestational age newborns during the first 48 hours. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Total bile acid levels are associated with left atrial volume and cardiac output in patients with cirrhosis

    DEFF Research Database (Denmark)

    Voiosu, Andrei M; Wiese, Signe; Voiosu, Theodor A

    2018-01-01

    , echocardiographic, and biochemical means. Associations between total serum BA concentrations and markers of systolic or diastolic dysfunction and the presence of cirrhotic cardiomyopathy were tested through univariate and multivariate analyses. RESULTS: Fifty-eight patients with cirrhosis were assessed...... and diastolic dysfunction were rare in the cohort. Total BA levels associated with several echocardiographic parameters of the hyperdynamic syndrome in univariate analysis but only with left atrial volume in multivariate analysis (P=0.007). BA concentrations did not differ according to the presence...... to investigate the association between total BA levels and echocardiographic and biochemical markers of cardiac dysfunction in cirrhotic patients. METHODS: Cirrhotic patients were enrolled prospectively in this hypothesis-generating study and evaluated for cardiac and hemodynamic dysfunction through clinical...

  6. Low cardiac output as physiological phenomenon in hibernating, free-ranging Scandinavian brown bears (Ursus arctos) - an observational study

    DEFF Research Database (Denmark)

    Jørgensen, Peter Godsk; Arnemo, Jon; Swenson, Jon E

    2014-01-01

    BACKGROUND: Despite 5-7 months of physical inactivity during hibernation, brown bears (Ursus arctos) are able to cope with physiological conditions that would be detrimental to humans. During hibernation, the tissue metabolic demands fall to 25% of the active state. Our objective was to assess...... cardiac function associated with metabolic depression in the hibernating vs. active states in free-ranging Scandinavian brown bears. METHODS: We performed echocardiography on seven free-ranging brown bears in Dalarna, Sweden, anesthetized with medetomidine-zolazepam-tiletamine-ketamine during winter.......31) l/min vs. 3.54 (SD: 1.04) l/min (P=0.003), and mean cardiac index 0.63 (SD: 0.21) l/min/kg vs. 2.45 (SD: 0.52) l/min/ m2 (Pbears during hibernation, despite the absence of atrial arrhythmias and valvular disease...

  7. Engineered hybrid cardiac patches with multifunctional electronics for online monitoring and regulation of tissue function.

    Science.gov (United States)

    Feiner, Ron; Engel, Leeya; Fleischer, Sharon; Malki, Maayan; Gal, Idan; Shapira, Assaf; Shacham-Diamand, Yosi; Dvir, Tal

    2016-06-01

    In cardiac tissue engineering approaches to treat myocardial infarction, cardiac cells are seeded within three-dimensional porous scaffolds to create functional cardiac patches. However, current cardiac patches do not allow for online monitoring and reporting of engineered-tissue performance, and do not interfere to deliver signals for patch activation or to enable its integration with the host. Here, we report an engineered cardiac patch that integrates cardiac cells with flexible, freestanding electronics and a 3D nanocomposite scaffold. The patch exhibited robust electronic properties, enabling the recording of cellular electrical activities and the on-demand provision of electrical stimulation for synchronizing cell contraction. We also show that electroactive polymers containing biological factors can be deposited on designated electrodes to release drugs in the patch microenvironment on demand. We expect that the integration of complex electronics within cardiac patches will eventually provide therapeutic control and regulation of cardiac function.

  8. Validation of maternal cardiac output assessed by transthoracic echocardiography against pulmonary artery catheterization in severely ill pregnant women: prospective comparative study and systematic review.

    Science.gov (United States)

    Cornette, J; Laker, S; Jeffery, B; Lombaard, H; Alberts, A; Rizopoulos, D; Roos-Hesselink, J W; Pattinson, R C

    2017-01-01

    Most severe pregnancy complications are characterized by profound hemodynamic disturbances, thus there is a need for validated hemodynamic monitoring systems for pregnant women. Pulmonary artery catheterization (PAC) using thermodilution is the clinical gold standard for the measurement of cardiac output (CO), however this reference method is rarely performed owing to its invasive nature. Transthoracic echocardiography (TTE) allows non-invasive determination of CO. We aimed to validate TTE against PAC for the determination of CO in severely ill pregnant women. This study consisted of a meta-analysis combining data from a prospective study and a systematic review. The prospective arm was conducted in Pretoria, South Africa, in 2003. Women with severe pregnancy complications requiring invasive monitoring with PAC according to contemporary guidelines were included. TTE was performed within 15 min of PAC and the investigator was blinded to the PAC measurements. Comparative measurements were extracted from similar studies retrieved from a systematic review of the literature and added to a database. Simultaneous CO measurements by TTE and PAC were compared. Agreement between methods was assessed using Bland-Altman statistics and intraclass correlation coefficients (ICC). Thirty-four comparative measurements were included in the meta-analysis. Mean CO values obtained by PAC and TTE were 7.39 L/min and 7.18 L/min, respectively. The bias was 0.21 L/min with lower and upper limits of agreement of -1.18 L/min and 1.60 L/min, percentage error was 19.1%, and ICC between the two methods was 0.94. CO measurements by TTE show excellent agreement with those obtained by PAC in pregnant women. Given its non-invasive nature and availability, TTE could be considered as a reference for the validation of other CO techniques in pregnant women. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Las complicaciones del embarazo más graves se caracterizan por trastornos hemodin

  9. Long-term recording of cardiac arrhythmias with an implantable cardiac monitor in patients with reduced ejection fraction after acute myocardial infarction: the Cardiac Arrhythmias and Risk Stratification After Acute Myocardial Infarction (CARISMA) study

    DEFF Research Database (Denmark)

    Bloch Thomsen, Poul Erik; Jons, Christian; Raatikainen, M J Pekka

    2010-01-01

    Knowledge about the incidence of cardiac arrhythmias after acute myocardial infarction has been limited by the lack of traditional ECG recording systems to document and confirm asymptomatic and symptomatic arrhythmias. The Cardiac Arrhythmias and Risk Stratification After Myocardial Infarction...... (CARISMA) trial was designed to study the incidence and prognostic significance of arrhythmias documented by an implantable cardiac monitor among patients with acute myocardial infarction and reduced left ventricular ejection fraction....

  10. A portable cadmium telluride multidetector probe for cardiac function monitoring

    CERN Document Server

    Arntz, Y; Dumitresco, B; Eclancher, B; Prat, V

    1999-01-01

    A new nuclear stethoscope based on a matrix of small CdTe semiconductor detectors has been developed for studying the cardiac performance by gamma ventriculography at the equilibrium, in rest and stress conditions, in the early and recovery phases of the coronary disease and to follow the long-term therapy. The light-weight probe consists of an array of 64 detectors 5x5x2 mm grouped in 16 independent units in a lead shielded aluminum box including 16 preamplifiers. The probe is connected to an electronic box containing DC power supply, 16 channel amplifiers, discriminators and counters, two analog-triggering ECG channels, and interface to a PC. The left ventricle activity is, preferentially, detected by using a low-resolution matching convergent collimator. A physical evaluation of the probe has been performed, both with static tests and dynamically with a hydraulic home-built model of beating heart ventricle paced by a rhythm simulator. The sum of the 16 detectors activity provided a radiocardiogram (RCG) wh...

  11. Noninvasive cardiac event monitoring to detect atrial fibrillation after ischemic stroke: a randomized, controlled trial.

    Science.gov (United States)

    Higgins, Peter; MacFarlane, Peter W; Dawson, Jesse; McInnes, Gordon T; Langhorne, Peter; Lees, Kennedy R

    2013-09-01

    Atrial fibrillation (AF) elevates risk of recurrent stroke but is incompletely identified by standard investigation after stroke, though detection rates correlate with monitoring duration. We hypothesized that 7 days of noninvasive cardiac-event monitoring early after stroke would accelerate detection of AF and thus uptake of effective therapy. We performed a pragmatic randomized trial with objective outcome assessment among patients presenting in sinus rhythm with no AF history, within 7 days of ischemic stroke symptom onset. Patients were randomized to standard practice investigations (SP) to detect AF, or SP plus additional monitoring (SP-AM). AM comprised 7 days of noninvasive cardiac-event monitoring reported by an accredited cardiac electrocardiology laboratory. Primary outcome was detection of AF at 14 days. One-hundred patients were enrolled from 2 centers. Within 14 days of stroke, sustained paroxysms of AF were detected in 18% of patients undergoing SP-AM versus 2% undergoing SP (Pstroke enhances detection of paroxysmal AF and early anticoagulation. Extended monitoring should be offered to all eligible patients soon after acute stroke. Guidelines on investigation for AF in stroke patients could be strengthened. http://www.controlled-trials.com/isrctn/. Unique identifier: ISRCTN97412358.

  12. The Utilization of an Insertable Cardiac Monitor in a Child With Pallid Breath-Holding Spells.

    Science.gov (United States)

    Tejman-Yarden, Shai; Ben-Zeev, Bruria; Goldshmit, Yuval; Sarquella-Brugada, Georgia; Cicurel, Assi; Katz, Uriel; Mishali, David; Glikson, Michael

    2016-11-01

    Pacing can be a successful treatment for pallid breath-holding spells, primarily in individuals with severe bradycardia. We describe an 18-month-old girl experiencing severe pallid breath-holding spells in whom repeated electrocardiographic, Holter, and electroencephalographic monitoring tests were all normal. Using a subcutaneous insertable cardiac monitor, severe bradycardia was detected during one of this girl's episodes. This finding led to a pacemaker implantation. Subsequently, her breath-holding spells completely resolved. This child illustrates the ability of the insertable cardiac monitor to help and diagnose arrhythmias in children with unresolved clinical findings. The ability to implant it with a minimal scar makes it ideal for uncooperative individuals with relative few and unexpected episodes that are hard to diagnose. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Effect of aging on cardiac function plus monitoring and support.

    Science.gov (United States)

    Martin, R Shayn; Farrah, Jason P; Chang, Michael C

    2015-02-01

    Cardiovascular disease is the most prevalent and influential comorbidity affecting outcomes in geriatric surgical patients. The unique physiology of the aging cardiovascular system and the impact of these changes during the stress of surgery is presented in this article. The necessary response to these changes is discussed with attention to methods of monitoring and recommendations for providing supportive care. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Remote monitoring of implantable cardiac devices: current state and future directions.

    Science.gov (United States)

    Ganeshan, Raj; Enriquez, Alan D; Freeman, James V

    2018-01-01

    Recent evidence has demonstrated substantial benefits associated with remote monitoring of cardiac implantable electronic devices (CIEDs), and treatment guidelines have endorsed the use of remote monitoring. Familiarity with the features of remote monitoring systems and the data supporting its use are vital for physicians' care for patients with CEIDs. Remote monitoring remains underutilized, but its use is expanding including in new practice settings including emergency departments. Patient experience and outcomes are positive, with earlier detection of clinical events such as atrial fibrillation, reductions in inappropriate implantable cardioverter-defibrillator (ICD) shocks and potentially a decrease in mortality with frequent remote monitoring utilizaiton. Rates of hospitalization are reduced among remote monitoring users, and the replacement of outpatient follow-up visits with remote monitoring transmissions has been shown to be well tolerated. In addition, health resource utilization is lower and remote monitoring has been associated with considerable cost savings. A dose relationship exists between use of remote monitoring and patient outcomes, and those with early and high transmission rates have superior outcomes. Remote monitoring provides clinicians with the ability to provide comprehensive follow-up care for patients with CIEDs. Patient outcomes are improved, and resource utilization is decreased with appropriate use of remote monitoring. Future efforts must focus on improving the utilization and efficiency of remote monitoring.

  15. Automated external cardioversion defibrillation monitoring in cardiac arrest: a randomized trial.

    Science.gov (United States)

    Ali, Bakhtiar; Bloom, Heather; Veledar, Emir; House, Dorothy; Norvel, Robert; Dudley, Samuel C; Zafari, A Maziar

    2008-06-11

    In-hospital cardiac arrest has a poor prognosis despite active electrocardiography monitoring. The initial rhythm of approximately 25% of in-hospital cardiopulmonary resuscitation (CPR) events is pulseless ventricular tachycardia/ventricular fibrillation (VT/VF). Early defibrillation is an independent predictor of survival in CPR events caused by VT/VF. The automated external cardioverter defibrillator (AECD) is a device attached by pads to the chest wall that monitors, detects, and within seconds, automatically delivers electric countershock to an appropriate tachyarrhythmia. To evaluate safety of AECD monitoring in hospitalized patients. To evaluate whether AECDs provide earlier defibrillation than hospital code teams. The study is a prospective trial randomizing patients admitted to the telemetry ward to standard CPR (code team) or standard CPR plus AECD monitoring (PowerHeart CRM). The AECD is programmed to deliver one 150 J biphasic shock to patients in sustained VT/VF. Data is collected using the Utstein criteria for cardiac arrest. The primary endpoint is time-to-defibrillation; secondary outcomes include neurological status and survival to discharge, with 3-year follow-up. To date, 192 patients have been recruited in the time period between 10/10/2006 to 7/20/2007. A total of 3,655 hours of telemetry data have been analyzed in the AECD arm. The AECD has monitored ambulatory telemetry patients in sinus rhythm, sinus tachycardia, supraventricular tachycardia, atrial flutter or fibrillation, with premature ventricular complexes and non-sustained VT without delivery of inappropriate shocks. One patient experienced sustained VT during AECD monitoring, who was successfully defibrillated (17 seconds after meeting programmed criteria). There are no events to report in the control arm. The patient survived the event without neurological complications. During the same time period, mean time to shock for VT/VF cardiac arrest occurring outside the telemetry ward was

  16. Fluid Balance, Change in Serum Creatinine and Urine Output as Markers of Acute Kidney Injury Post Cardiac Surgery: An Observational Study

    Directory of Open Access Journals (Sweden)

    Katrina Chau

    2014-08-01

    Full Text Available Background: Acute kidney injury (AKI is defined as oliguria or rise in serum creatinine but oliguria alone as a diagnostic criterion may over-diagnose AKI. Objectives: Given the association between fluid overload and AKI, we aimed to determine if positive fluid balance can complement the known parameters in assessing outcomes of AKI. Design: Prospective observational study. Setting: Teaching hospital in Vancouver, Canada. Patients: 111 consecutive patients undergoing elective cardiac surgery from January to April 2012. Measurements: Outcomes of cardiac surgery intensive care unit (CSICU and hospital length of stay (LOS in relation to fluid balance, urine output and serum creatinine. Methods: All fluid input and output was recorded for 72 hours post-operatively. Positive fluid balance was defined as >6.5 cc/kg. Daily serum creatinine and hourly urine output were recorded and patients were defined as having AKI according to the AKIN criteria. Results: Of the patients who were oliguric, those with fluid overload trended towards longer LOS than those without fluid overload [CSICU LOS: 62 and 39 hours (unadjusted p-value 0.02, adjusted p-value 0.58; hospital LOS: 13 and 9 days (unadjusted p-value: 0.05, adjusted p-value: 0.16]. Patients with oliguria who were fluid overloaded had similar LOS to patients with overt AKI (change in serum creatinine ≥ 26.5 μmol/L, [CSICU LOS: 62 and 69 hours (adjusted p value: 0.32 and hospital LOS: 13 and 14 days (adjusted p value: 0.19]. Patients with oliguria regardless of fluid balance had longer CSICU LOS (adjusted p value: 0.001 and patients who were fluid overloaded in the absence of AKI had longer hospital LOS (adjusted p value: 0.02. Limitations: Single centre, small sample, LOS as outcome. Conclusions: Oliguria and positive fluid balance is associated with a trend towards longer LOS as compared to oliguria alone. Fluid balance may therefore be a useful marker of AKI, in addition to urine output and serum

  17. The remote exercise monitoring trial for exercise-based cardiac rehabilitation (REMOTE-CR): a randomised controlled trial protocol

    OpenAIRE

    Maddison, Ralph; Rawstorn, Jonathan C; Rolleston, Anna; Whittaker, Robyn; Stewart, Ralph; Benatar, Jocelyne; Warren, Ian; Jiang, Yannan; Gant, Nicholas

    2014-01-01

    Background Exercise is an essential component of contemporary cardiac rehabilitation programs for the secondary prevention of coronary heart disease. Despite the benefits associated with regular exercise, adherence with supervised exercise-based cardiac rehabilitation remains low. Increasingly powerful mobile technologies, such as smartphones and wireless physiological sensors, may extend the capability of exercise-based cardiac rehabilitation by enabling real-time exercise monitoring for tho...

  18. System for the diagnosis and monitoring of coronary artery disease, acute coronary syndromes, cardiomyopathy and other cardiac conditions

    Science.gov (United States)

    Schlegel, Todd T. (Inventor); Arenare, Brian (Inventor)

    2008-01-01

    Cardiac electrical data are received from a patient, manipulated to determine various useful aspects of the ECG signal, and displayed and stored in a useful form using a computer. The computer monitor displays various useful information, and in particular graphically displays various permutations of reduced amplitude zones and kurtosis that increase the rapidity and accuracy of cardiac diagnoses. New criteria for reduced amplitude zones are defined that enhance the sensitivity and specificity for detecting cardiac abnormalities.

  19. Content validation of the operational definitions of the nursing diagnoses of activity intolerance, excess fluid volume, and decreased cardiac output in patients with heart failure.

    Science.gov (United States)

    de Souza, Vanessa; Zeitoun, Sandra Salloum; Lopes, Camila Takao; de Oliveira, Ana Paula Dias; Lopes, Juliana de Lima; de Barros, Alba Lucia Botura Leite

    2014-06-01

    To consensually validate the operational definitions of the nursing diagnoses activity intolerance, excessive fluid volume, and decreased cardiac output in patients with decompensated heart failure. Consensual validation was performed in two stages: analogy by similarity of defining characteristics, and development of operational definitions and validation with experts. A total of 38 defining characteristics were found. Operational definitions were developed and content-validated. One hundred percent of agreement was achieved among the seven experts after five rounds. "Ascites" was added in the nursing diagnosis excessive fluid volume. The consensual validation improves interpretation of human response, grounding the selection of nursing interventions and contributing to improved nursing outcomes. Support the assessment of patients with decompensated heart failure. © 2013 NANDA International.

  20. Feasibility of Stereo-Infrared Tracking to Monitor Patient Motion During Cardiac SPECT Imaging

    OpenAIRE

    Beach, Richard D.; Pretorius, P. Hendrik; Boening, Guido; Bruyant, Philippe P.; Feng, Bing; Fulton, Roger R.; Gennert, Michael A.; Nadella, Suman; King, Michael A.

    2004-01-01

    Patient motion during cardiac SPECT imaging can cause diagnostic imaging artifacts. We investigated the feasibility of monitoring patient motion using the Polaris motion-tracking system. This system uses passive infrared reflection from small spheres to provide real-time position data with vendor stated 0.35 mm accuracy and 0.2 mm repeatability. In our configuration, the Polaris system views through the SPECT gantry toward the patient's head. List-mode event data was temporally synchronized w...

  1. Oxygen saturation and heart rate monitoring during a single session of early rehabilitation after cardiac surgery.

    Science.gov (United States)

    Sala, Vittorio; Petrucci, Lucia; Monteleone, Serena; Dall'Angelo, Anna; Miracca, Stefania; Conte, Teresa; Carlisi, Ettore; Ricotti, Susanna; D'Armini, Andrea M; Dalla Toffola, Elena

    2016-02-01

    Early rehabilitation after cardiac surgery aims to prevent immobilization, to reduce the effects of surgery on the respiratory function and to facilitate the recovery of autonomy in the activities of daily living (ADL), after discharge. Nevertheless the optimal perioperative physical therapy care for patients undergoing cardiac surgery is not well established. Moreover, most of the studies monitored peripheral oxygen saturation (SpO2) and heart rate (HR) during surgery or focused only on their recovery after rehabilitation and not on their pathways during a session of exercises. To monitor peripheral oxygen saturation and HR before, during and at the end of a single session of early rehabilitation after cardiac surgery, so testing our protocol's safety. A case series. Department of Cardiothoracic Surgery, inpatients. Forty-eight consecutive inpatients (35 M), mean age 61 years, with cardiovascular disease (CVD), who underwent cardiac surgery. We monitored SpO2%, HR, systemic blood pressure (BP), pain in the thoracic wound (VAS) and rate of perceived exertion (RPE) during the rehabilitation session after weaning from oxygen therapy. During all phases mean SpO2 was 94% (±1.8) and mean HR was 85 bpm (±13.3). Number of desaturation events were 14 in total and mean of % of time with SpO2<90% was 3 (±6.5) during all the rehabilitative session. Moreover, mean BP after reaching the sitting position was 124.7 (±11.9)/78.6 (±8.4) and after ambulation was 131.5 (±11.5)/82.9 (±7.3). The monitoring peripheral oxygen saturation and HR during and not only before and at the end of a standardized early rehabilitation session helped us to ensure the safety of our protocol. Because of its feasibility, safety and reproducibility our rehabilitation treatment has been applied to different types of surgical inpatients in order to limit the negative consequences of immobilization.

  2. Uncomplicated human type 2 diabetes is associated with meal-induced blood pressure lowering and cardiac output increase.

    Science.gov (United States)

    Smits, Mark M; Muskiet, Marcel H A; Tushuizen, Maarten E; Kwa, Kelly A A; Karemaker, John M; van Raalte, Daniël H; Diamant, Michaela

    2014-12-01

    Since many type 2 diabetes patients experience postprandial hypotension, the aim of this study was to unravel meal-related changes in systemic hemodynamics and autonomic nervous system (ANS)-balance. Forty-two age-matched males (15 type 2 diabetes; 12 metabolic syndrome; 15 controls) without overt autonomic neuropathy received a standardized high-fat mixed meal after an overnight fast. Hemodynamic variables were measured by finger plethysmography. Fourier analysis was used to calculate the low-/high-frequency (LF/HF)-ratio, a marker of autonomic nervous system-balance, and baroreceptor reflex sensitivity (BRS). Following the meal, diastolic blood pressure (DBP) decreased in type 2 diabetes patients only, paralleled by a significant decrement in systemic vascular resistance (SVR) and an increase in cardiac index. All groups showed an increase in postprandial heart rate. Controls, but not metabolic syndrome or type 2 diabetes patients, showed a meal-related increase in LF/HF-ratio. When combining all study subjects, homeostatic model assessment-insulin resistance (HOMA-IR) was inversely correlated with changes in DBP, SVR, LF/HF-ratio and BRS. Based on these data, we hypothesize that in patients with uncomplicated type 2 diabetes, insulin resistance hampers adequate meal-induced sympathetic activation, leading to a decrease in SVR and resulting in a postprandial drop in DBP. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  3. Diagnostic Yield of Extended Cardiac Patch Monitoring in Patients with Stroke or TIA

    Directory of Open Access Journals (Sweden)

    Christie E Tung

    2015-01-01

    Full Text Available Background: It is important to evaluate patients with TIA or stroke for atrial fibrillation (AF because the detection of AF changes the recommended anti-thrombotic regimen from treatment with an antiplatelet agent to oral anticoagulation. This study describes the diagnostic yield of a patch-based, single-use, and water-resistant 14-day continuous cardiac rhythm monitor (ZIO Patch in patients with stroke or TIA.Methods: We obtained data from the manufacturer and servicer of the ZIO Patch (iRhythm Technologies. Patients who were monitored between January 2012 and June 2013 and whose indication for monitoring was TIA or stroke were included. The duration of monitoring, the number and type of arrhythmias, and the time to first arrhythmia were documented. Results: 1,171 monitoring reports were analyzed. The mean monitor wear time was 10.9 days and the median wear time was 13.0 days (interquartile range 7.2-14.0. The median analyzable time relative to the total wear time was 98.7% (IQR 96.0-99.5%. AF was present in 5.0% of all reports. The mean duration before the first episode of paroxysmal AF (PAF was 1.5 days and the median duration was 0.4 days. 14.3% of first PAF episodes occurred after 48 hours. The mean PAF burden was 12.7% of the total monitoring duration. Conclusion: Excellent quality of the recordings and very good patient compliance coupled with a substantial proportion of AF detection beyond the first 48 hours of monitoring suggest that the cardiac patch is superior to conventional 48-hour Holter monitors for AF detection in patients with stroke or TIA.

  4. Limited Evidence for Risk Factors for Proarrhythmia and Sudden Cardiac Death in Patients Using Antidepressants: Dutch Consensus on ECG Monitoring

    NARCIS (Netherlands)

    Simoons, M. (Mirjam); K.A. Seldenrijk (Kees); H. Mulder (Hans); T.K. Birkenhäger (Tom); Groothedde-Kuyvenhoven, M. (Mascha); Kok, R. (Rob); C. Kramers; W. Verbeeck (Wim); Westra, M. (Mirjam); E.N. van Roon (Eric); Bakker, R. (Roberto); H.G. Ruhé (Henricus G.Eric)

    2018-01-01

    textabstractCurrently, there is a lack of international and national guidelines or consensus documents with specific recommendations for electrocardiogram (ECG) screening and monitoring during antidepressant treatment. To make a proper estimation of the risk of cardiac arrhythmias and sudden

  5. Evaluation of an empirical monitor output estimation in carbon ion radiotherapy.

    Science.gov (United States)

    Matsumura, Akihiko; Yusa, Ken; Kanai, Tatsuaki; Mizota, Manabu; Ohno, Tatsuya; Nakano, Takashi

    2015-09-01

    A conventional broad beam method is applied to carbon ion radiotherapy at Gunma University Heavy Ion Medical Center. According to this method, accelerated carbon ions are scattered by various beam line devices to form 3D dose distribution. The physical dose per monitor unit (d/MU) at the isocenter, therefore, depends on beam line parameters and should be calibrated by a measurement in clinical practice. This study aims to develop a calculation algorithm for d/MU using beam line parameters. Two major factors, the range shifter dependence and the field aperture effect, are measured via PinPoint chamber in a water phantom, which is an identical setup as that used for monitor calibration in clinical practice. An empirical monitor calibration method based on measurement results is developed using a simple algorithm utilizing a linear function and a double Gaussian pencil beam distribution to express the range shifter dependence and the field aperture effect. The range shifter dependence and the field aperture effect are evaluated to have errors of 0.2% and 0.5%, respectively. The proposed method has successfully estimated d/MU with a difference of less than 1% with respect to the measurement results. Taking the measurement deviation of about 0.3% into account, this result is sufficiently accurate for clinical applications. An empirical procedure to estimate d/MU with a simple algorithm is established in this research. This procedure allows them to use the beam time for more treatments, quality assurances, and other research endeavors.

  6. On the Design of an Efficient Cardiac Health Monitoring System Through Combined Analysis of ECG and SCG Signals.

    Science.gov (United States)

    Sahoo, Prasan Kumar; Thakkar, Hiren Kumar; Lin, Wen-Yen; Chang, Po-Cheng; Lee, Ming-Yih

    2018-01-28

    Cardiovascular disease (CVD) is a major public concern and socioeconomic problem across the globe. The popular high-end cardiac health monitoring systems such as magnetic resonance imaging (MRI), computerized tomography scan (CT scan), and echocardiography (Echo) are highly expensive and do not support long-term continuous monitoring of patients without disrupting their activities of daily living (ADL). In this paper, the continuous and non-invasive cardiac health monitoring using unobtrusive sensors is explored aiming to provide a feasible and low-cost alternative to foresee possible cardiac anomalies in an early stage. It is learned that cardiac health monitoring based on sole usage of electrocardiogram (ECG) signals may not provide powerful insights as ECG provides shallow information on various cardiac activities in the form of electrical impulses only. Hence, a novel low-cost, non-invasive seismocardiogram (SCG) signal along with ECG signals are jointly investigated for the robust cardiac health monitoring. For this purpose, the in-laboratory data collection model is designed for simultaneous acquisition of ECG and SCG signals followed by mechanisms for the automatic delineation of relevant feature points in acquired ECG and SCG signals. In addition, separate feature points based novel approach is adopted to distinguish between normal and abnormal morphology in each ECG and SCG cardiac cycle. Finally, a combined analysis of ECG and SCG is carried out by designing a Naïve Bayes conditional probability model. Experiments on Institutional Review Board (IRB) approved licensed ECG/SCG signals acquired from real subjects containing 12,000 cardiac cycles show that the proposed feature point delineation mechanisms and abnormal morphology detection methods consistently perform well and give promising results. In addition, experimental results show that the combined analysis of ECG and SCG signals provide more reliable cardiac health monitoring compared to the

  7. Nursing-Based Dysrhythmia Detection on a Dedicated Stroke Unit Using a Unit-Based Cardiac Telemetry Monitoring System.

    Science.gov (United States)

    Jastrzebski, Cheryl; Hernandez, Erika; Nadis, Susan; Lichtenberg, Robert

    Acute stroke care includes cardiac rhythm monitoring in the first 24 hours. The method of monitoring varies, as do the reported findings. The nurses' role in this process can be intensive, including primary response and review of all data. Competency is critical as the acute stroke setting can be associated with life-threatening dysrhythmias as well as the detection of atrial fibrillation that affects therapy. Limited studies exist to evaluate the effectiveness of a unit-based cardiac monitoring system for which the bedside nurse has primary responsibility. The goal was to determine if a unit-based cardiac monitoring system for which the bedside nurse was responsible detected clinically significant dysrhythmias. Stroke unit nurses completed a mandatory education program on identifying common dysrhythmias and using the monitoring equipment along with a structured algorithm for cardiac dysrhythmia detection. The nurse was responsible for all alarms as well as review of their patients' data. Their findings were recorded and reviewed by a cardiology team after the 24-hour monitoring was completed. A total of 300 consecutive stokes, transient ischemic attack, and possible stroke patients were enrolled. Nurses identified 96% of all significant dysrhythmias. Twenty-eight percent of the stroke patients had a dysrhythmia, of which 79% were atrial fibrillation/atrial flutter. The bedside nurses did identify all 8 new atrial fibrillation cases. Stroke unit nurses who complete an educational program can identify dysrhythmias on their patients' unit-based cardiac monitoring systems and can improve patient outcomes.

  8. Automated external cardioversion defibrillation monitoring in cardiac arrest: a randomized trial

    Directory of Open Access Journals (Sweden)

    Norvel Robert

    2008-06-01

    Full Text Available Abstract Background In-hospital cardiac arrest has a poor prognosis despite active electrocardiography monitoring. The initial rhythm of approximately 25% of in-hospital cardiopulmonary resuscitation (CPR events is pulseless ventricular tachycardia/ventricular fibrillation (VT/VF. Early defibrillation is an independent predictor of survival in CPR events caused by VT/VF. The automated external cardioverter defibrillator (AECD is a device attached by pads to the chest wall that monitors, detects, and within seconds, automatically delivers electric countershock to an appropriate tachyarrhythmia. Study Objectives • To evaluate safety of AECD monitoring in hospitalized patients. • To evaluate whether AECDs provide earlier defibrillation than hospital code teams. Methods The study is a prospective trial randomizing patients admitted to the telemetry ward to standard CPR (code team or standard CPR plus AECD monitoring (PowerHeart CRM. The AECD is programmed to deliver one 150 J biphasic shock to patients in sustained VT/VF. Data is collected using the Utstein criteria for cardiac arrest. The primary endpoint is time-to-defibrillation; secondary outcomes include neurological status and survival to discharge, with 3-year follow-up. Results To date, 192 patients have been recruited in the time period between 10/10/2006 to 7/20/2007. A total of 3,655 hours of telemetry data have been analyzed in the AECD arm. The AECD has monitored ambulatory telemetry patients in sinus rhythm, sinus tachycardia, supraventricular tachycardia, atrial flutter or fibrillation, with premature ventricular complexes and non-sustained VT without delivery of inappropriate shocks. One patient experienced sustained VT during AECD monitoring, who was successfully defibrillated (17 seconds after meeting programmed criteria. There are no events to report in the control arm. The patient survived the event without neurological complications. During the same time period, mean time to

  9. Improving risk assessment for post-surgical low cardiac output syndrome in patients without severely reduced ejection fraction undergoing open aortic valve replacement. The role of global longitudinal strain and right ventricular free wall strain

    NARCIS (Netherlands)

    Balderas-Munoz, K.; Rodriguez-Zanella, H.; Fritche-Salazar, J. F.; Avila-Vanzzini, N.; Juarez Orozco, L. E.; Arias-Godinez, J. A.; Calvillo-Arguelles, O.; Rivera-Peralta, S.; Sauza-Sosa, J. C.; Ruiz-Esparza, M. E.; Bucio-Reta, E.; Rmero, A.; Espinola-Zavaleta, N.; Dominguez-Mendez, B.; Gaxiola-Macias, M.; Martinez-Rios, M. A.

    2017-01-01

    Low cardiac output syndrome (LCOS) after surgical aortic valve replacement (SAVR) is related to increased mortality and treatment related costs. We aimed to evaluate whether echocardiography-derived left ventricular global longitudinal strain (LV-GLS) relates to the occurrence of postoperative LCOS

  10. Comparison of stroke volume and cardiac output as measured by a single observer using four different ultrasound techniques in six clinically healthy cats.

    Science.gov (United States)

    Biermann, K; Hungerbühler, S; Kästner, S B R

    2012-12-01

    The aim of this study was to assess agreement and repeatability of four ultrasound methods for measuring stroke volume (SV) and cardiac output (CO) in cats. Measurement of SV and CO was performed by the Teichholz method, the Simpson's method (SM), the area length method (ALM) and a volumetric flow method across the aorta (Trace method). For each method, the coefficient of variation (CV) was calculated and agreement was determined by Bland-Altman analysis. The CV was acceptable (parameters, except for SV and CO obtained by SM (28.8% and 22.4%, respectively) and ALM (21.6% and 22.6%, respectively). Narrow limits of agreement were observed between both planimetric methods (SM and ALM). The Trace method was the most repeatable, followed by the Teichholz method. Despite excellent inter-method agreement, neither of the planimetric methods produced results with adequate repeatability. As the Teichholz and Trace methods were acceptably repeatable, and probably gave the most representative values, they appear to be the most useful methods for the measurement of SV and CO in cats. Further investigations are needed to compare the echocardiographic methods described here with a standard technique such as thermodilution. Copyright © 2012. Published by Elsevier Ltd.

  11. Phosphodiesterase inhibitor KMUP-3 displays cardioprotection via protein kinase G and increases cardiac output via G-protein-coupled receptor agonist activity and Ca2+ sensitization

    Directory of Open Access Journals (Sweden)

    Chung-Pin Liu

    2016-02-01

    Full Text Available KMUP-3 (7-{2-[4-(4-nitrobenzene piperazinyl]ethyl}-1, 3-dimethylxanthine displays cardioprotection and increases cardiac output, and is suggested to increase cardiac performance and improve myocardial infarction. To determine whether KMUP-3 improves outcomes in hypoperfused myocardium by inducing Ca2+ sensitization to oppose protein kinase (PKG-mediated Ca2+ blockade, we measured left ventricular systolic blood pressure, maximal rates of pressure development, mean arterial pressure and heart rate in rats, and measured contractility and expression of PKs/RhoA/Rho kinase (ROCKII in beating guinea pig left atria. Hemodynamic changes induced by KMUP-3 (0.5–3.0 mg/kg, intravenously were inhibited by Y27632 [(R-(+-trans-4-1-aminoethyl-N-(4-Pyridyl cyclohexane carboxamide] and ketanserin (1 mg/kg, intravenously. In electrically stimulated left guinea pig atria, positive inotropy induced by KMUP-3 (0.1–100μM was inhibited by the endothelial NO synthase (eNOS inhibitors N-nitro-l-arginine methyl ester (L-NAME and 7-nitroindazole, cyclic AMP antagonist SQ22536 [9-(terahydro-2-furanyl-9H-purin-6-amine], soluble guanylyl cyclase (sGC antagonist ODQ (1H-[1,2,4] oxadiazolo[4,3-a] quinoxalin-1-one, RhoA inhibitor C3 exoenzyme, β-blocker propranolol, 5-hydroxytryptamine 2A antagonist ketanserin, ROCK inhibitor Y27632 and KMUP-1 (7-{2-[4-(2-chlorobenzene piperazinyl]ethyl}-1, 3-dimethylxanthine at 10μM. Western blotting assays indicated that KMUP-3 (0.1–10μM increased PKA, RhoA/ROCKII, and PKC translocation and CIP-17 (an endogenous 17-kDa inhibitory protein activation. In spontaneous right atria, KMUP-3 induced negative chronotropy that was blunted by 7-nitroindazole and atropine. In neonatal myocytes, L-NAME inhibited KMUP-3-induced eNOS phosphorylation and RhoA/ROCK activation. In H9c2 cells, Y-27632 (50μM and PKG antagonist KT5823 [2,3,9,10,11,12-hexahydro-10R- methoxy-2,9-dimethyl-1-oxo-9S,12R-epoxy-1H-diindolo(1,2,3-fg:3′,2′,1

  12. A comparison of volume clamp method-based continuous noninvasive cardiac output (CNCO) measurement versus intermittent pulmonary artery thermodilution in postoperative cardiothoracic surgery patients.

    Science.gov (United States)

    Wagner, Julia Y; Körner, Annmarie; Schulte-Uentrop, Leonie; Kubik, Mathias; Reichenspurner, Hermann; Kluge, Stefan; Reuter, Daniel A; Saugel, Bernd

    2018-04-01

    The CNAP technology (CNSystems Medizintechnik AG, Graz, Austria) allows continuous noninvasive arterial pressure waveform recording based on the volume clamp method and estimation of cardiac output (CO) by pulse contour analysis. We compared CNAP-derived CO measurements (CNCO) with intermittent invasive CO measurements (pulmonary artery catheter; PAC-CO) in postoperative cardiothoracic surgery patients. In 51 intensive care unit patients after cardiothoracic surgery, we measured PAC-CO (criterion standard) and CNCO at three different time points. We conducted two separate comparative analyses: (1) CNCO auto-calibrated to biometric patient data (CNCO bio ) versus PAC-CO and (2) CNCO calibrated to the first simultaneously measured PAC-CO value (CNCO cal ) versus PAC-CO. The agreement between the two methods was statistically assessed by Bland-Altman analysis and the percentage error. In a subgroup of patients, a passive leg raising maneuver was performed for clinical indications and we present the changes in PAC-CO and CNCO in four-quadrant plots (exclusion zone 0.5 L/min) in order to evaluate the trending ability of CNCO. The mean difference between CNCO bio and PAC-CO was +0.5 L/min (standard deviation ± 1.3 L/min; 95% limits of agreement -1.9 to +3.0 L/min). The percentage error was 49%. The concordance rate was 100%. For CNCOcal, the mean difference was -0.3 L/min (±0.5 L/min; -1.2 to +0.7 L/min) with a percentage error of 19%. In this clinical study in cardiothoracic surgery patients, CNCO cal showed good agreement when compared with PAC-CO. For CNCO bio , we observed a higher percentage error and good trending ability (concordance rate 100%).

  13. Cardiac monitoring for detection of atrial fibrillation after TIA: A systematic review and meta-analysis.

    Science.gov (United States)

    Korompoki, Eleni; Del Giudice, Angela; Hillmann, Steffi; Malzahn, Uwe; Gladstone, David J; Heuschmann, Peter; Veltkamp, Roland

    2017-01-01

    Background and purpose The detection rate of atrial fibrillation has not been studied specifically in transient ischemic attack (TIA) patients although extrapolation from ischemic stroke may be inadequate. We conducted a systematic review and meta-analysis to determine the rate of newly diagnosed atrial fibrillation using different methods of ECG monitoring in TIA. Methods A comprehensive literature search was performed following a pre-specified protocol the PRISMA statement. Prospective observational studies and randomized controlled trials were considered that included TIA patients who underwent cardiac monitoring for >12 h. Primary outcome was frequency of detection of atrial fibrillation ≥30 s. Analyses of subgroups and of duration and type of monitoring were performed. Results Seventeen studies enrolling 1163 patients were included. The pooled atrial fibrillation detection rate for all methods was 4% (95% CI: 2-7%). Yield of monitoring was higher in selected (higher age, more extensive testing for arrhythmias before enrolment, or presumed cardioembolic/cryptogenic cause) than in unselected cohorts (7% vs 3%). Pooled mean atrial fibrillation detection rates rose with duration of monitoring: 4% (24 h), 5% (24 h to 7 days) and 6% (>7 days), respectively. Yield of non-invasive was significantly lower than that of invasive monitoring (4% vs. 11%). Significant heterogeneity was observed among studies (I 2 =60.61%). Conclusion This first meta-analysis of atrial fibrillation detection in TIA patients finds a lower atrial fibrillation detection rate in TIA than reported for IS and TIA cohorts in previous meta-analyses. Prospective studies are needed to determine actual prevalence of atrial fibrillation and optimal diagnostic procedure for atrial fibrillation detection in TIA.

  14. Cardiotoxicity and Cardiac Monitoring During Adjuvant Trastuzumab in Daily Dutch Practice: A Study of the Southeast Netherlands Breast Cancer Consortium

    NARCIS (Netherlands)

    Seferina, S.C.; Boer, M. de; Derksen, M.W.J.; Berkmortel, F. van den; Kampen, R.J. van; Wouw, A.J. van de; Joore, M.; Peer, P.G.M.; Voogd, A.C.; Tjan-Heijnen, V.C.

    2016-01-01

    INTRODUCTION: We assessed the incidence and timing of first cardiac events, impact on trastuzumab prescription, and role of left ventricular ejection fraction (LVEF) monitoring in daily practice of trastuzumab-treated patients with human epidermal growth receptor 2 (HER2)-positive early breast

  15. Cardiac Acceleration at the Onset of Exercise : A Potential Parameter for Monitoring Progress During Physical Training in Sports and Rehabilitation

    NARCIS (Netherlands)

    Hettinga, Florentina J.; Monden, Paul G.; van Meeteren, Nico L. U.; Daanen, Hein A. M.

    There is a need for easy-to-use methods to assess training progress in sports and rehabilitation research. The present review investigated whether cardiac acceleration at the onset of physical exercise (HRonset) can be used as a monitoring variable. The digital databases of Scopus and PubMed were

  16. Cardiac acceleration at the onset of exercise: A potential parameter for monitoring progress during physical training in sports and rehabilitation

    NARCIS (Netherlands)

    Hettinga, F.J.; Monden, P.G.; Meeteren, N.L.U. van; Daanen, H.A.M.

    2014-01-01

    There is a need for easy-to-use methods to assess training progress in sports and rehabilitation research. The present review investigated whether cardiac acceleration at the onset of physical exercise (HRonset) can be used as a monitoring variable. The digital databases of Scopus and PubMed were

  17. A Submaximal Running Test With Postexercise Cardiac Autonomic and Neuromuscular Function in Monitoring Endurance Training Adaptation.

    Science.gov (United States)

    Vesterinen, Ville; Nummela, Ari; Laine, Tanja; Hynynen, Esa; Mikkola, Jussi; Häkkinen, Keijo

    2017-01-01

    Vesterinen, V, Nummela, A, Laine, T, Hynynen, E, Mikkola, J, and Häkkinen, K. A submaximal running test with postexercise cardiac autonomic and neuromuscular function in monitoring endurance training adaptation. J Strength Cond Res 31(1): 233-243, 2017-The aim of this study was to investigate whether a submaximal running test (SRT) with postexercise heart rate recovery (HRR), heart rate variability (HRV), and countermovement jump (CMJ) measurements could be used to monitor endurance training adaptation. Thirty-five endurance-trained men and women completed an 18-week endurance training. Maximal endurance performance and maximal oxygen uptake were measured every 8 weeks. In addition, SRTs with postexercise HRR, HRV, and CMJ measurements were carried out every 4 weeks. Submaximal running test consisted of two 6-minute stages at 70 and 80% of maximum heart rate (HRmax) and a 3-minute stage at 90% HRmax, followed by a 2-minute recovery stage for measuring postexercise HRR, HRV, and CMJ test. The highest responders according to the change of maximal endurance performance showed a significant improvement in running speeds during stages 2 and 3 in SRT, whereas no changes were observed in the lowest responders. The strongest correlation was found between the change of maximal endurance performance and running speed during stage 3, whereas no significant relationships were found between the change of maximal endurance performance and the changes of postexercise HRR, HRV, and CMJ. Running speed at 90% HRmax intensity was the most sensitive variable to monitor adaptation to endurance training. The present submaximal test showed potential to monitor endurance training adaptation. Furthermore, it may serve as a practical tool for athletes and coaches to evaluate weekly the effectiveness of training program without interfering in the normal training habits.

  18. Intramyocardial electrogram recordings for diagnosis and therapy monitoring of cardiac allograft rejection.

    Science.gov (United States)

    Grauhan, O; Warnecke, H; Müller, J; Knosalla, C; Cohnert, T; Voss, A; Hetzer, R

    1993-01-01

    The registration of intramyocardial ECG amplitudes (IMEG) is a non-invasive diagnostic method of monitoring cardiac allograft rejection. In order to detect possible sources of error IMEG signals were recorded in heterotopic neck hearts in ten beagle dogs. Immunosuppression was based on cyclosporin A. The rejection process was followed by IMEG registrations as well as by serial myocardial biopsies. Intramyocardial electrogram recordings were made via three unipolar and three bipolar leads obtained from screw-in electrodes in both ventricles and the apex of the allograft. A 10% voltage drop was used as an indicator of rejection. In four dogs, the first rejection episode was treated with methyl-prednisolone and the therapy's success was monitored by IMEG and repeat biopsy. At autopsy the histology of each electrode circumference was correlated with the corresponding IMEG. The average sensitivity of a single lead was not acceptable (unipolar: 28%, bipolar: 47%). When the voltages of different leads were summed up the sensitivity rose to 43% (3 x unipolar), 85% (3 x bipolar) and 100% (all leads). During rejection therapy the IMEG recovered within 24-48 h. We conclude that in moderate allograft rejection (grade 2/3a ISHT classification), the rejection-related changes of intramyocardial ECG voltage amplitude (IMEG) seem to follow a "focal pattern" similar to the histology. Therefore the recording of several, preferably bipolar, electrode configurations appears to enhance adequate diagnostic reliability.

  19. The remote exercise monitoring trial for exercise-based cardiac rehabilitation (REMOTE-CR): a randomised controlled trial protocol.

    Science.gov (United States)

    Maddison, Ralph; Rawstorn, Jonathan C; Rolleston, Anna; Whittaker, Robyn; Stewart, Ralph; Benatar, Jocelyne; Warren, Ian; Jiang, Yannan; Gant, Nicholas

    2014-11-28

    Exercise is an essential component of contemporary cardiac rehabilitation programs for the secondary prevention of coronary heart disease. Despite the benefits associated with regular exercise, adherence with supervised exercise-based cardiac rehabilitation remains low. Increasingly powerful mobile technologies, such as smartphones and wireless physiological sensors, may extend the capability of exercise-based cardiac rehabilitation by enabling real-time exercise monitoring for those with coronary heart disease. This study compares the effectiveness of technology-assisted, home-based, remote monitored exercise-based cardiac rehabilitation (REMOTE) to standard supervised exercise-based cardiac rehabilitation in New Zealand adults with a diagnosis of coronary heart disease. A two-arm, parallel, non-inferiority, randomised controlled trial will be conducted at two sites in New Zealand. One hundred and sixty two participants will be randomised at a 1:1 ratio to receive a 12-week program of technology-assisted, home-based, remote monitored exercise-based cardiac rehabilitation (intervention), or an 8-12 program of standard supervised exercise-based cardiac rehabilitation (control).The primary outcome is post-treatment maximal oxygen uptake (V̇O2max). Secondary outcomes include cardiovascular risk factors (blood lipid and glucose concentrations, blood pressure, anthropometry), self-efficacy, intentions and motivation to be active, objectively measured physical activity, self-reported leisure time exercise and health-related quality of life. Cost information will also be collected to compare the two modes of delivery. All outcomes are assessed at baseline, post-treatment, and 6 months, except for V̇O2max, blood lipid and glucose concentrations, which are assessed at baseline and post-treatment only. This novel study will compare the effectiveness of technology-supported exercise-based cardiac rehabilitation to a traditional supervised approach. If the REMOTE program

  20. Bortezomib-Induced Complete Heart Block and Myocardial Scar: The Potential Role of Cardiac Biomarkers in Monitoring Cardiotoxicity

    Directory of Open Access Journals (Sweden)

    Sachin Diwadkar

    2016-01-01

    Full Text Available Bortezomib is a proteasome inhibitor used to treat multiple myeloma and mantle cell lymphoma. Traditionally, bortezomib was thought to have little cardiovascular toxicity; however, there is increasing evidence that bortezomib can lead to cardiac complications including left ventricular dysfunction and atrioventricular block. We present the case of a 66-year-old man with multiple myeloma and persistent asymptomatic elevations of cardiac biomarkers who developed complete heart block and evidence of myocardial scar after his eighth cycle of bortezomib, requiring permanent pacemaker placement. In addition to discussing the cardiovascular complications of bortezomib therapy, we propose a potential role for biomarkers in the prediction and monitoring of bortezomib cardiotoxicity.

  1. Cardiovascular Ultrasound of Neonatal Long Evans Rats Exposed Prenatally to Trichloroacetic Acid: Effects on Heart Rate, Ejection Fraction, and Cardiac Output

    Science.gov (United States)

    This abstract describes the use of a relatively new technology, cardiovascular ultrasound (echocardiography) for evaluating developmental toxicity affecting heart development. The abstract describes the effects of two known cardiac teratogens, trichloroacetic acid and dimethadio...

  2. Results of remote follow-up and monitoring in young patients with cardiac implantable electronic devices.

    Science.gov (United States)

    Silvetti, Massimo S; Saputo, Fabio A; Palmieri, Rosalinda; Placidi, Silvia; Santucci, Lorenzo; Di Mambro, Corrado; Righi, Daniela; Drago, Fabrizio

    2016-01-01

    Remote monitoring is increasingly used in the follow-up of patients with cardiac implantable electronic devices. Data on paediatric populations are still lacking. The aim of our study was to follow-up young patients both in-hospital and remotely to enhance device surveillance. This is an observational registry collecting data on consecutive patients followed-up with the CareLink system. Inclusion criteria were a Medtronic device implanted and patient's willingness to receive CareLink. Patients were stratified according to age and presence of congenital/structural heart defects (CHD). A total of 221 patients with a device - 200 pacemakers, 19 implantable cardioverter defibrillators, and two loop recorders--were enrolled (median age of 17 years, range 1-40); 58% of patients were younger than 18 years of age and 73% had CHD. During a follow-up of 12 months (range 4-18), 1361 transmissions (8.9% unscheduled) were reviewed by technicians. Time for review was 6 ± 2 minutes (mean ± standard deviation). Missed transmissions were 10.1%. Events were documented in 45% of transmissions, with 2.7% yellow alerts and 0.6% red alerts sent by wireless devices. No significant differences were found in transmission results according to age or presence of CHD. Physicians reviewed 6.3% of transmissions, 29 patients were contacted by phone, and 12 patients underwent unscheduled in-hospital visits. The event recognition with remote monitoring occurred 76 days (range 16-150) earlier than the next scheduled in-office follow-up. Remote follow-up/monitoring with the CareLink system is useful to enhance device surveillance in young patients. The majority of events were not clinically relevant, and the remaining led to timely management of problems.

  3. Real-Time Monitoring in Home-Based Cardiac Rehabilitation Using Wrist-Worn Heart Rate Devices

    Directory of Open Access Journals (Sweden)

    Javier Medina Quero

    2017-12-01

    Full Text Available Cardiac rehabilitation is a key program which significantly reduces the mortality in at-risk patients with ischemic heart disease; however, there is a lack of accessibility to these programs in health centers. To resolve this issue, home-based programs for cardiac rehabilitation have arisen as a potential solution. In this work, we present an approach based on a new generation of wrist-worn devices which have improved the quality of heart rate sensors and applications. Real-time monitoring of rehabilitation sessions based on high-quality clinical guidelines is embedded in a wearable application. For this, a fuzzy temporal linguistic approach models the clinical protocol. An evaluation based on cases is developed by a cardiac rehabilitation team.

  4. The role of cardiac disease parameters in predicting the results of Holter monitoring in patients with acute ischaemic stroke.

    Science.gov (United States)

    Atmuri, Kiran; Hughes, Andrew; Coles, David; Ahmad, Omar; Neeman, Teresa; Lueck, Christian

    2012-07-01

    There is limited evidence supporting the routine use of Holter monitoring (HM) in patients with acute ischaemic stroke. This study aimed to assess the diagnostic yield of HM and determine whether any cardiac disease parameter(s) would permit more focused targeting of HM. We performed a retrospective evaluation of HM in patients with acute ischaemic stroke admitted to our hospital over a one-year period to assess diagnostic yield and whether certain cardiac disease parameters were correlated with HM results. The diagnostic yield was 9%, the number needed to screen was 11, and the cost to detect one clinically significant case was AUS$1,300. Apart from age, stratifying patients by cardiac disease parameters did not predict HM result. This strengthens the use of HM in all patients presenting with acute ischaemic stroke of unknown aetiology. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Input-output supervisor

    International Nuclear Information System (INIS)

    Dupuy, R.

    1970-01-01

    The input-output supervisor is the program which monitors the flow of informations between core storage and peripheral equipments of a computer. This work is composed of three parts: 1 - Study of a generalized input-output supervisor. With sample modifications it looks like most of input-output supervisors which are running now on computers. 2 - Application of this theory on a magnetic drum. 3 - Hardware requirement for time-sharing. (author) [fr

  6. Monitoring of immune activation using biochemical changes in a porcine model of cardiac arrest

    Directory of Open Access Journals (Sweden)

    Anton Amann

    2001-01-01

    Full Text Available In animal models, immune activation is often difficult to assess because of the limited availability of specific assays to detect cytokine activities. In human monocytes/macrophages, interferon-γ induces increased production of neopterin and an enhanced activity of indoleamine 2,3-dioxygenase, which degrades tryptophan via the kynurenine pathway. Therefore, monitoring of neopterin concentrations and of tryptophan degradation can serve to detect the extent of T helper cell 1-type immune activation during cellular immune response in humans. In a porcine model of cardiac arrest, we examined the potential use of neopterin measurements and determination of the tryptophan degradation rate as a means of estimating the extent of immune activation. Urinary neopterin concentrations were measured with high-performance liquid chromatography (HPLC and radioimmunoassay (RIA (BRAHMS Diagnostica, Berlin, Germany. Serum and plasma tryptophan and kynurenine concentrations were also determined using HPLC. Serum and urine neopterin concentrations were not detectable with HPLC in these specimens, whereas RIA gave weakly (presumably false positive results. The mean serum tryptophan concentration was 39.0 Ī 6.2 μmol/l, and the mean kynurenine concentration was 0.85 Ī 0.33 μmol/l. The average kynurenine-per-tryptophan quotient in serum was 21.7Ī 8.4 nmol/μmol, and that in plasma was 20.7Ī 9.5 nmol/μmol (n = 7, which corresponds well to normal values in humans. This study provides preliminary data to support the monitoring of tryptophan degradation but not neopterin concentrations as a potential means of detecting immune activation in a porcine model. The kynurenine-per-tryptophan quotient may serve as a short-term measurement of immune activation and hence permit an estimate of the extent of immune activation.

  7. Development and feasibility of a smartphone, ECG and GPS based system for remotely monitoring exercise in cardiac rehabilitation.

    Directory of Open Access Journals (Sweden)

    Charles Worringham

    Full Text Available BACKGROUND: Despite its efficacy and cost-effectiveness, exercise-based cardiac rehabilitation is undertaken by less than one-third of clinically eligible cardiac patients in every country for which data is available. Reasons for non-participation include the unavailability of hospital-based rehabilitation programs, or excessive travel time and distance. For this reason, there have been calls for the development of more flexible alternatives. METHODOLOGY AND PRINCIPAL FINDINGS: We developed a system to enable walking-based cardiac rehabilitation in which the patient's single-lead ECG, heart rate, GPS-based speed and location are transmitted by a programmed smartphone to a secure server for real-time monitoring by a qualified exercise scientist. The feasibility of this approach was evaluated in 134 remotely-monitored exercise assessment and exercise sessions in cardiac patients unable to undertake hospital-based rehabilitation. Completion rates, rates of technical problems, detection of ECG changes, pre- and post-intervention six minute walk test (6 MWT, cardiac depression and Quality of Life (QOL were key measures. The system was rated as easy and quick to use. It allowed participants to complete six weeks of exercise-based rehabilitation near their homes, worksites, or when travelling. The majority of sessions were completed without any technical problems, although periodic signal loss in areas of poor coverage was an occasional limitation. Several exercise and post-exercise ECG changes were detected. Participants showed improvements comparable to those reported for hospital-based programs, walking significantly further on the post-intervention 6 MWT, 637 m (95% CI: 565-726, than on the pre-test, 524 m (95% CI: 420-655, and reporting significantly reduced levels of cardiac depression and significantly improved physical health-related QOL. CONCLUSIONS AND SIGNIFICANCE: The system provided a feasible and very flexible alternative form of

  8. Burnout versus work engagement in their effects on 24-hour ambulatory monitored cardiac autonomic function

    NARCIS (Netherlands)

    L.J.P. van Doornen (Lorenz); J.H. Houtveen (Jan); S. Langelaan (Saar); A.B. Bakker (Arnold); W. van Rhenen (Willem); W.B. Schaufeli (Wilmar)

    2009-01-01

    textabstractBurnout has been associated with increased risk of cardiovascular disease. This relationship may be mediated by a stress-related disruption in cardiac autonomic activity. The aim of the present study was to assess cardiac autonomic activity (sympathetic and parasympathetic) during a

  9. Aortic and Hepatic Contrast Enhancement During Hepatic-Arterial and Portal Venous Phase Computed Tomography Scanning: Multivariate Linear Regression Analysis Using Age, Sex, Total Body Weight, Height, and Cardiac Output.

    Science.gov (United States)

    Masuda, Takanori; Nakaura, Takeshi; Funama, Yoshinori; Higaki, Toru; Kiguchi, Masao; Imada, Naoyuki; Sato, Tomoyasu; Awai, Kazuo

    We evaluated the effect of the age, sex, total body weight (TBW), height (HT) and cardiac output (CO) of patients on aortic and hepatic contrast enhancement during hepatic-arterial phase (HAP) and portal venous phase (PVP) computed tomography (CT) scanning. This prospective study received institutional review board approval; prior informed consent to participate was obtained from all 168 patients. All were examined using our routine protocol; the contrast material was 600 mg/kg iodine. Cardiac output was measured with a portable electrical velocimeter within 5 minutes of starting the CT scan. We calculated contrast enhancement (per gram of iodine: [INCREMENT]HU/gI) of the abdominal aorta during the HAP and of the liver parenchyma during the PVP. We performed univariate and multivariate linear regression analysis between all patient characteristics and the [INCREMENT]HU/gI of aortic- and liver parenchymal enhancement. Univariate linear regression analysis demonstrated statistically significant correlations between the [INCREMENT]HU/gI and the age, sex, TBW, HT, and CO (all P linear regression analysis showed that only the TBW and CO were of independent predictive value (P linear regression analysis only the TBW and CO were significantly correlated with aortic and liver parenchymal enhancement; the age, sex, and HT were not. The CO was the only independent factor affecting aortic and liver parenchymal enhancement at hepatic CT when the protocol was adjusted for the TBW.

  10. Use of [18F]FDG PET to Monitor The Development of Cardiac Allograft Rejection

    Science.gov (United States)

    Daly, Kevin P.; Dearling, Jason L. J.; Seto, Tatsuichiro; Dunning, Patricia; Fahey, Frederic; Packard, Alan B.; Briscoe, David M.

    2014-01-01

    Background Positron Emission Tomography (PET) has the potential to be a specific, sensitive and quantitative diagnostic test for transplant rejection. To test this hypothesis, we evaluated 18F-labeled fluorodeoxyglucose ([18F]FDG) and 13N-labeled ammonia ([13N]NH3) small animal PET imaging in a well-established murine cardiac rejection model. Methods Heterotopic transplants were performed using minor MHC mismatched B6.C-H2bm12 donor hearts in C57BL/6(H-2b) recipients. C57BL/6 donor hearts into C57BL/6 recipients served as isograft controls. [18F]FDG PET imaging was performed weekly between post-transplant days 7 and 42 and the percent injected dose was computed for each graft. [13N]NH3 imaging was performed to evaluate myocardial perfusion. Results There was a significant increase in [18F]FDG uptake in allografts from day 14 to day 21 (1.6% to 5.2%; Ptransplant days 21 (5.2% vs. 0.9%; P=0.005) and 28 (4.8% vs. 0.9%; P=0.006) compared to isograft controls. Furthermore, [18F]FDG uptake correlated with an increase in rejection within allografts between days 14 and 28 post-transplant. Finally, the uptake of [13N]NH3 was significantly lower relative to the native heart in allografts with chronic vasculopathy compared to isograft controls on day 28 (P=0.01). Conclusions PET imaging with [18F]FDG can be used following transplantation to monitor the evolution of rejection. In addition, decreased uptake of [13N]NH3 in rejecting allografts may be reflective of decreased myocardial blood flow. These data suggest that combined [18F]FDG and [13N]NH3 PET imaging could be used as a non-invasive, quantitative technique for serial monitoring of allograft rejection and has potential application in human transplant recipients. PMID:25675207

  11. Phase II intensive monitored cardiac rehabilitation for coronary artery disease and coronary risk factors--a six-session protocol.

    Science.gov (United States)

    Fletcher, B J; Thiel, J; Fletcher, G F

    1986-04-01

    To evaluate phase II intensive monitored cardiac rehabilitation using a 6-level, 6-session protocol, 31 patients were placed in a progressive 6-level exercise protocol with careful supervision and assessment of heart rate, rhythm, blood pressure and perceived exertion. Duration after the cardiac event ranged from 12 days to 8 years (median 10 months). Each exercise prescription was based on exercise testing with oxygen consumption determinations. Exercise activities were individually prescribed according to percentages of maximal MET level achieved on the exercise test. Each exercise session incorporated calisthenics, treadmill exercise, and bicycle and arm ergometry with progressively greater workloads on the various stations. All patients completed the 6 levels within 6 sessions of approximately 1 hour each, and achieved their designated 50 to 75% target heart rate with perceived exertion level 13 or less. There were no critical cardiac events, i.e., high-grade ventricular arrhythmias or myocardial infarction. All completed the 6-level protocol and progressed to a nonmonitored exercise program with no difficulty. The results of this short-term method of telemetry-monitored rehabilitation suggest benefits of proper exercise instruction, successful achievement of the 50 to 75% exercise target heart rate, detection of minor new arrhythmias and alterations of blood pressure response, adequate use of the perceived exertion scale, and a safe and effective transition to subsequent exercise programs.

  12. Characterization of radiation exposure and effect of a radiation monitoring policy in a large volume pediatric cardiac catheterization lab.

    Science.gov (United States)

    Verghese, George R; McElhinney, Doff B; Strauss, Keith J; Bergersen, Lisa

    2012-02-01

    This study aimed to characterize radiation dose during cardiac catheterization in congenital heart disease and to assess changes in dose after the introduction of a radiation monitoring policy. Minimizing radiation exposure is an important patient safety initiative and relatively few data are available characterizing radiation dose for the broad spectrum of congenital cardiac catheter-based interventions. Radiation dose data were reviewed on all cases since 7/1/05 at a single large center. Procedures were classified according to 20 common case types then subdivided into five age categories. Groups with product, μGym(2)) which were reported as median and interquartile range (IQR). We also examined differences in radiation dose before and after the implementation of a radiation policy. Between 7/1/05 and 12/10/08, 3,365 cases were identified for inclusion. Radiation dose increased with age and procedural complexity. Patients were characterized into low, medium, and high dose categories relative to each other. "Low" dose cases included isolated pulmonary or aortic valvotomy, pre-Fontan assessment, and ASD closure. "High" dose cases involved multiple procedures in pulmonary arteries or veins. After introduction of a radiation policy, there was a significant decrease in radiation dose across a variety of case types, particularly among infants and young children. Radiation dose in congenital cardiac catheterization varies by age and procedure type. A radiation monitoring and notification policy may have contributed to reduced radiation dose. Copyright © 2011 Wiley Periodicals, Inc.

  13. The use of an improved technique to reduce the variability of output voltage in real-time Fibre Bragg Grating based monitoring system

    Science.gov (United States)

    Vorathin, E.; Hafizi, Z. M.; Che Ghani, S. A.; Lim, K. S.; Aizzuddin, A. M.

    2017-10-01

    Fibre Bragg Grating (FBG) sensors have been widely utilized in the structural health monitoring (SHM) of structures. However, one of the main challenges of FBGs is the existence of inconsistency in output voltage during wavelength intensity demodulation utilizing photodetector (PD) to convert the light signal into digital voltage readings. Thus, the designation of this experimental work is to develop a robust FBG real-time monitoring system with the benefit of MATLAB graphical user interface (GUI) and voltage normalization algorithm to scale down the voltage inconsistency. Low-cost edge filter interrogation system has been practiced in the experimentation and splitter optical component is make use to reduce the intensity of the high power light source that leads to the formation of noise due to unwanted reflected wavelengths. The results revealed that with the advancement of the proposed monitoring system, the sensitivity of the FBG has been increased from 2.4 mV/N to 3.8 mV/N across the range of 50 N. The redundancy in output voltage variation data points has been reduced from 26 data/minute to 17 data/minute. The accuracy of the FBG in detecting the load induced falls in the acceptable range of total average error which is 1.38 %.

  14. External drift kriging of NOx concentrations with dispersion model output in a reduced air quality monitoring network

    NARCIS (Netherlands)

    Kassteele, van de J.; Stein, A.; Dekkers, A.L.M.; Velders, G.J.M.

    2009-01-01

    In the mid nineteen eighties the Dutch NOx air quality monitoring network was reduced from 73 to 32 rural and city background stations, leading to higher spatial uncertainties. In this study, several other sources of information are being used to help reduce uncertainties in parameter estimation and

  15. Implementing an institution-wide quality improvement policy to ensure appropriate use of continuous cardiac monitoring: a mixed-methods retrospective data analysis and direct observation study.

    Science.gov (United States)

    Rayo, Michael F; Mansfield, Jerry; Eiferman, Daniel; Mignery, Traci; White, Susan; Moffatt-Bruce, Susan D

    2016-10-01

    Hospitals have been slow to adopt guidelines from the American Heart Association (AHA) limiting the use of continuous cardiac monitoring for fear of missing important patient cardiac events. A new continuous cardiac monitoring policy was implemented at a tertiary-care hospital seeking to monitor only those patients who were clinically indicated and decrease the number of false alarms in order to improve overall alarm response. Leadership support was secured, a cross-functional alarm management task force was created, and a system-wide policy was developed based on current AHA guidelines. Process measures, including cardiac monitoring rate, monitored transport rate, emergency department (ED) boarding rate and the percentage of false, unnecessary and true alarms, were measured to determine the policy's impact on patient care. Outcome measures, including length of stay and mortality rate, were measured to determine the impact on patient outcomes. Cardiac monitoring rate decreased 53.2% (0.535 to 0.251 per patient day, pimprovements in process measures coupled with no adverse effects to patient outcomes suggest that the overall system became more resilient to current and emerging demands. This study indicates that when collaboration across a diverse team is coupled with strong leadership support, policies and procedures such as this one can improve clinical practice and patient care. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  16. Bench-to-bedside review: An approach to hemodynamic monitoring--Guyton at the bedside.

    Science.gov (United States)

    Magder, Sheldon

    2012-10-29

    Hemodynamic monitoring is used to identify deviations from hemodynamic goals and to assess responses to therapy. To accomplish these goals one must understand how the circulation is regulated. In this review I begin with an historical review of the work of Arthur Guyton and his conceptual understanding of the circulation and then present an approach by which Guyton's concepts can be applied at the bedside. Guyton argued that cardiac output and central venous pressure are determined by the interaction of two functions: cardiac function, which is determined by cardiac performance; and a return function, which is determined by the return of blood to the heart. This means that changes in cardiac output are dependent upon changes of one of these two functions or of both. I start with an approach based on the approximation that blood pressure is determined by the product of cardiac output and systemic vascular resistance and that cardiac output is determined by cardiac function and venous return. A fall in blood pressure with no change in or a rise in cardiac output indicates that a decrease in vascular resistance is the dominant factor. If the fall in blood pressure is due to a fall in cardiac output then the role of a change in the return function and cardiac function can be separated by the patterns of changes in central venous pressure and cardiac output. Measurement of cardiac output is a central component to this approach but until recently it was not easy to obtain and was estimated from surrogates. However, there are now a number of non-invasive devices that can give measures of cardiac output and permit the use of physiological principles to more rapidly appreciate the primary pathophysiology behind hemodynamic abnormalities and to provide directed therapy.

  17. Prolonged Cardiac Monitoring to Detect Atrial Fibrillation after Cryptogenic Stroke or Transient Ischemic Attack: A Meta-Analysis of Randomized Controlled Trials.

    Science.gov (United States)

    Dahal, Khagendra; Chapagain, Bikas; Maharjan, Raju; Farah, Hussam W; Nazeer, Ayesha; Lootens, Robert J; Rosenfeld, Alan

    2016-07-01

    The cause of ischemic stroke or transient ischemic attack (TIA) remains unclear after initial cardiac monitoring in approximately one-third of patients. Randomized controlled trials (RCTs) showed that the prolonged cardiac monitoring of patients with cryptogenic stroke or TIA increased detection of atrial fibrillation (AF). We aimed to perform a meta-analysis of all RCTs that evaluated the prolonged monitoring ≥7 days in patients with cryptogenic stroke or TIA. We searched PubMed, EMBASE, Cochrane CENTRAL, and relevant references for RCTs without language restriction (inception through December 2014) and performed meta-analysis using random effects model. Detection of AF, use of anticoagulation at follow-up, recurrent stroke or TIA, and mortality were major outcomes. Four RCTs with 1149 total patients were included in the meta-analysis. Prolonged cardiac monitoring ≥7 days compared to shorter cardiac monitoring of ≤48 hours duration increased the detection of AF (≥30 seconds duration) in patients after cryptogenic stroke or TIA (13.8% vs. 2.5%; odds ratio [OR], 6.4; 95% confidence interval [CI], 3.50-11.73; P vs. 5.2%; 5.68[3.3-9.77]; P stroke or TIA (0.78[0.40-1.55]; P = 0.48; I(2) , 0%) and mortality (1.33[0.29-6.00]; P = 0.71; I(2) , 0%] were observed between two strategies. Prolonged cardiac monitoring improves detection of atrial fibrillation and anti-coagulation use after cryptogenic stroke or TIA and therefore should be considered instead of shorter duration of cardiac monitoring. © 2015 Wiley Periodicals, Inc.

  18. Microfluidic system for monitoring of cardiac (H9C2) cell proliferation

    Science.gov (United States)

    Kobuszewska, A.; Cwik, P.; Jastrzebska, E.; Brzozka, Z.; Chudy, M.; Renaud, P.; Dybko, A.

    2017-05-01

    The paper presents the application of electrical impedance spectroscopy (EIS) analysis for investigation of cardiac cell (H9C2 - rat cardiomyoblast) proliferation after verapamil hydrochloride exposure. For this purpose, two different PDMS/glass microsystems with circular microchamber and longitudinal microchannel integrated with Pt/Al electrodes were used. The microchambers were fabricated in PDMS using photolithography and replica moulding techniques. Pt/Al electrodes were fabricated on a 4-inch glass substrate using Physical Vapor Deposition (PVD). Solution of verapamil hydrochloride was continuously introduced into the microsystems with H9C2 cell culture (a flow rate of 1 μl/min) for 72 h. The impedance spectra were recorded from 100 Hz to 1 MHz. We confirmed that impedance spectroscopy can be used for non-invasive, label-free and real-time analysis of cardiac cells proliferation based on cells dielectric properties and biological structure.

  19. Yonjung High-Speed Railway Bridge Assessment Using Output-Only Structural Health Monitoring Measurements under Train Speed Changing

    Directory of Open Access Journals (Sweden)

    Mosbeh R. Kaloop

    2016-01-01

    Full Text Available Yonjung Bridge is a hybrid multispan bridge that is designed to transport high-speed trains (HEMU-430X with maximum operating speed of 430 km/h. The bridge consists of simply supported prestressed concrete (PSC and composite steel girders to carry double railway tracks. The structural health monitoring system (SHM is designed and installed to investigate and assess the performance of the bridge in terms of acceleration and deformation measurements under different speeds of the passing train. The SHM measurements are investigated in both time and frequency domains; in addition, several identification models are examined to assess the performance of the bridge. The drawn conclusions show that the maximum deflection and acceleration of the bridge are within the design limits that are specified by the Korean and European codes. The parameters evaluation of the model identification depicts the quasistatic and dynamic deformations of PSC and steel girders to be different and less correlated when higher speeds of the passing trains are considered. Finally, the variation of the frequency content of the dynamic deformations of the girders is negligible when high speeds are considered.

  20. Evaluation of bluetooth low power for physiological monitoring in a home based cardiac rehabilitation program.

    Science.gov (United States)

    Martin, Timothy; Ding, Hang; D'Souza, Matthew; Karunanithi, Mohan

    2012-01-01

    Cardiovascular disease (CVD) is the leading cause of mortality in Australia, and places large burdens on the healthcare system. To assist patients with CVDs in recovering from cardiac events and mediating cardiac risk factors, a home based cardiac rehabilitation program, known as the Care Assessment Platform (CAP), was developed. In the CAP program, patients are required to manually enter health information into their mobile phones on a daily basis. The manual operation is often subject to human errors and is inconvenient for some elderly patients. To improve this, an automated wireless solution has been desired. The objectives of this paper are to investigate the feasibility of implementing the newly released Bluetooth 4.0 (BT4.0) for the CAP program, and practically evaluate BT4.0 communications between a developed mobile application and some emulated healthcare devices. The study demonstrated that BT4.0 addresses usability, interoperability and security for healthcare applications, reduces the power consumption in wireless communication, and improves the flexibility of interface for software development. This evaluation study provides an essential mobile BT4.0 framework to incorporate a large range of healthcare devices for clinical assessment and intervention in the CAP program, and hence it is useful for similar development and research work of other mobile healthcare solutions.

  1. A wearable cardiac monitor for long-term data acquisition and analysis.

    Science.gov (United States)

    Winokur, Eric S; Delano, Maggie K; Sodini, Charles G

    2013-01-01

    A low-power wearable ECG monitoring system has been developed entirely from discrete electronic components and a custom PCB. This device removes all loose wires from the system and minimizes the footprint on the user. The monitor consists of five electrodes, which allow a cardiologist to choose from a variety of possible projections. Clinical tests to compare our wearable monitor with a commercial clinical ECG recorder are conducted on ten healthy adults under different ambulatory conditions, with nine of the datasets used for analysis. Data from both monitors were synchronized and annotated with PhysioNet's waveform viewer WAVE (physionet.org) [1]. All gold standard annotations are compared to the results of the WQRS detection algorithm [2] provided by PhysioNet. QRS sensitivity and QRS positive predictability are extracted from both monitors to validate the wearable monitor.

  2. Cardiac gated ventilation

    Science.gov (United States)

    Hanson, C. William, III; Hoffman, Eric A.

    1995-05-01

    There are several theoretic advantages to synchronizing positive pressure breaths with the cardiac cycle, including the potential for improving distribution of pulmonary and myocardial blood flow and enhancing cardiac output. We evaluated the effects of synchronizing respiration to the cardiac cycle using a programmable ventilator and electron beam CT (EBCT) scanning. The hearts of anesthetized dogs were imaged during cardiac gated respiration with a 50msec scan aperture. Multislice, short axis, dynamic image data sets spanning the apex to base of the left ventricle were evaluated to determine the volume of the left ventricular chamber at end-diastole and end-systole during apnea, systolic and diastolic cardiac gating. We observed an increase in cardiac output of up to 30% with inspiration gated to the systolic phase of the cardiac cycle in a nonfailing model of the heart.

  3. Assessment of cardiac function and circulatory status in critically ill patients

    Directory of Open Access Journals (Sweden)

    Gorazd Voga

    2007-12-01

    Full Text Available Background: Assessment of cardiac function and circulation is mandatory in almost all critically ill patients. In many patients morphological diagnosis of actual or pre-existing cardiac diseases and their functional consequences should be obtained.Methods: Cardiac function can be assessed by various non-invasive and invasive methods. The value of every method should be assessed according to its ability and reliability to assess preload, cardiac output and the adequacy of flow. In hemodinamically unstable patients frequent reassessment must be performed, because of rapid changes of patients’ conditions. Therefore, all methods for hemodynamic assessment in the ICU must be available on the 24 hours basis. Combined non-invasive and invasive approach to the assessment of cardiac function and circulation is preferred. After initial assessment of cardiac function according to clinical examination, electrocardiogram, chest X-ray and blood gas analysis, echocardiography is routinely used. When continuous monitoring of cardiac function is mandatory, complete invasive monitoring with pulmonary artery catheter and arterial line is employed. Monitoring of pulmonary pressures, continuous cardiac output, mixed venous blood oxygen saturation, and parameters of right ventricular function is the best choice to obtain complete information of hemodynamic situation. In patients with increased pulmonary vascular permeability the monitoring of cardiac output by pulse contour method together with measurement of intrathoracic blood volume and extravascular lung water could be even better choice.Conclusions: Assessment of cardiac function and circulatory status by rational use of various non-invasive and invasive methods is one of the essential components of critical care management.

  4. Radial artery applanation tonometry for continuous noninvasive arterial blood pressure monitoring in the cardiac intensive care unit.

    Science.gov (United States)

    Langwieser, Nicolas; Prechtl, Luisa; Meidert, Agnes S; Hapfelmeier, Alexander; Bradaric, Christian; Ibrahim, Tareq; Laugwitz, Karl-Ludwig; Schmid, Roland M; Wagner, Julia Y; Saugel, Bernd

    2015-06-01

    Hemodynamic monitoring plays a pivotal role in the treatment of patients in the cardiac intensive care unit (CICU). The innovative radial artery applanation tonometry technology allows for continuous noninvasive arterial blood pressure (AP) measurement. By closing the gap between continuous invasive AP monitoring (arterial catheter) and intermittent noninvasive AP monitoring (oscillometry) this technology might improve CICU patient monitoring. We therefore aimed to evaluate the measurement performance of radial artery applanation tonometry in comparison with a radial arterial catheter in CICU patients. In this prospective method comparison study, we simultaneously recorded AP noninvasively with radial artery applanation tonometry (T-line 200 pro device; Tensys Medical Inc., San Diego, CA, USA) and invasively with an arterial catheter (criterion standard) in 30 patients treated in the CICU of a German university hospital. We statistically analyzed 7,304 averaged 10-beat epochs of measurements of mean AP, systolic AP, and diastolic AP by using Bland-Altman analysis for repeated measurements. Our study revealed a mean difference ± standard deviation (95% limits of agreement; percentage error) between radial artery applanation tonometry and the criterion standard method (radial arterial catheter) of +2 ± 6 mmHg (-10 to +14 mmHg; 17%) for mean AP, -6 ± 11 mmHg (-28 to +15 mmHg; 20%) for systolic AP, and +4 ± 7 mmHg (-9 to +17 mmHg; 23%) for diastolic AP. In CICU patients, continuous noninvasive measurement of AP using radial artery applanation tonometry is feasible. The technology showed reasonable accuracy and precision in comparison with radial arterial catheter-derived AP values.

  5. First measurements of gas output from bubbling pools in a mud volcano at the periphery of Mt Etna (Italy): methodologies and implications for monitoring purposes

    Science.gov (United States)

    Federico, Cinzia; Giudice, Gaetano; Liuzzo, Marco; Pedone, Maria; Cosenza, Paolo; Riccobono, Giuseppe

    2014-05-01

    angles. The positions of both laser source and retro-reflectors were chosen so to have the target CO2 plume in between retro-reflectors and the GasFinder, and to realize the complete coverage of the degassing area. We therefore explored the possibility to combine the available path-integrated CO2 concentration data to derive a two-dimensional mapping of CO2 over the mud volcano. The periodic survey of total CO2 output in a subset of vigorously degassing pools, paralleled to the chemical and isotopic measurements routinely performed in selected pools, would offer a robust monitoring tool in a peripheral sector of the volcano. Chiodini G., D'Alessandro W. and Parello F. (1996) Geochemistry of gases and water discharged by the mud volcanoes at Paternò, Mt. Etna (Italy). Bull. Volcanol. 58, 51-58. Paonita A., Caracausi A., Iacono-Marziano G., Martelli M., Rizzo A. (2012) Geochemical evidence for mixing between fluids exsolved at different depths in the magmatic system of Mt Etna (Italy). Geochim. Cosmochim. Acta 84 (2012) 380-394.

  6. Acebutolol in Cardiac Arrhythmias

    African Journals Online (AJOL)

    1974-04-20

    Apr 20, 1974 ... the cardiac output at rest and on exercise is not altered by the administration of acebutolol, and in patients with coronary artery disease, intravenous acebutolol produces a small fall in cardiac index, stroke index and in the parameters which are used to measure left ventricular. contractilityYo. We have used ...

  7. Boron-doped nanocrystalline diamond microelectrode arrays monitor cardiac action potentials.

    Science.gov (United States)

    Maybeck, Vanessa; Edgington, Robert; Bongrain, Alexandre; Welch, Joseph O; Scorsone, Emanuel; Bergonzo, Philippe; Jackman, Richard B; Offenhäusser, Andreas

    2014-02-01

    The expansion of diamond-based electronics in the area of biological interfacing has not been as thoroughly explored as applications in electrochemical sensing. However, the biocompatibility of diamond, large safe electrochemical window, stability, and tunable electronic properties provide opportunities to develop new devices for interfacing with electrogenic cells. Here, the fabrication of microelectrode arrays (MEAs) with boron-doped nanocrystalline diamond (BNCD) electrodes and their interfacing with cardiomyocyte-like HL-1 cells to detect cardiac action potentials are presented. A nonreductive means of structuring doped and undoped diamond on the same substrate is shown. The resulting BNCD electrodes show high stability under mechanical stress generated by the cells. It is shown that by fabricating the entire surface of the MEA with NCD, in patterns of conductive doped, and isolating undoped regions, signal detection may be improved up to four-fold over BNCD electrodes passivated with traditional isolators. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Telecommunication monitoring is a method for studies of the effect of heliomagnetic fluctuations on cardiac function.

    Science.gov (United States)

    Chibisov, S M; Vishnevsky, V V; Ragulskaya, M V

    2008-06-01

    This paper presents the results of 9-year biogeophysical monitoring (1998-2007) of spatial and time effects of space weather and atmospheric and climatic factors on the status of normal subjects, which was carried out simultaneously in geographical areas situated at different latitudes. Requirements to conditions of long-term telecommunication biogeophysical monitoring studies are formulated, providing the reliability and reproducibility of the experiment results. The results indicate that the role of atmospheric and climatic factors in modification of dynamic regimens of human body functioning is significantly higher in subjects living at lower latitudes. The spatial and time regularities of the effects of space and physical factors on human body were detected (the latitude, time, trigger, amplitude, synergetic, and cumulative effects of the population averaging of the reaction). These effects indicate that human body belongs to a class of open nonlinear dynamic systems with all characteristics intrinsic of it.

  9. Miniaturized Human Insertable Cardiac Monitoring System with Wireless Power Transmission Technique

    Directory of Open Access Journals (Sweden)

    Jong-Ha Lee

    2016-01-01

    Full Text Available Prolonged monitoring is more likely to diagnose atrial fibrillation accurately than intermittent or short-term monitoring. In this study, an implantable electrocardiograph (ECG sensor to monitor atrial fibrillation patients in real time was developed. The implantable sensor is composed of a micro controller unit, an analog-to-digital converter, a signal transmitter, an antenna, and two electrodes. The sensor detects ECG signals from the two electrodes and transmits these to an external receiver carried by the patient. Because the sensor continuously transmits signals, its battery consumption rate is extremely high; therefore, the sensor includes a wireless power transmission module that allows it to charge wirelessly from an external power source. The integrated sensor has the approximate dimensions 3 mm × 4 mm × 14 mm, which is small enough to be inserted into a patient without the need for major surgery. The signal and power transmission data sampling rate and frequency of the unit are 300 samples/s and 430 Hz, respectively. To validate the developed sensor, experiments were conducted on small animals.

  10. Blood pressure and heart rate from the arterial blood pressure waveform can reliably estimate cardiac output in a conscious sheep model of multiple hemorrhages and resuscitation using computer machine learning approaches.

    Science.gov (United States)

    Liu, Nehemiah T; Kramer, George C; Khan, Muzna N; Kinsky, Michael P; Salinas, José

    2015-10-01

    This study was a first step to facilitate the development of automated decision support systems using cardiac output (CO) for combat casualty care. Such systems remain a practical challenge in battlefield and prehospital settings. In these environments, reliable CO estimation using blood pressure (BP) and heart rate (HR) may provide additional capabilities for diagnosis and treatment of trauma patients. The aim of this study was to demonstrate that continuous BP and HR from the arterial BP waveform coupled with machine learning (ML) can reliably estimate CO in a conscious sheep model of multiple hemorrhages and resuscitation. Hemodynamic parameters (BPs, HR) were derived from 100-Hz arterial BP waveforms of 10 sheep records, 3 hours to 4 hours long. Two models (mean arterial pressure, Windkessel) were then applied and merged to estimate COVS. ML was used to develop a rule for identifying when models required calibration. All records contained 100-Hz recording of pulmonary arterial blood flow using Doppler transit time (COFP). COFP and COVS were analyzed using equivalence tests and Bland-Altman analysis, as well as waveform and concordance plots. Baseline COFP varied from 3.0 L/min to 5.4 L/min, while posthemorrhage COFP varied from 1.0 L/min to 1.8 L/min. A total of 315,196 pairs of data were obtained. Equivalence tests for individual records showed that COVS was statistically equivalent to COFP (p < 0.05). Smaller equivalence thresholds (<0.3 L/min) indicated an overall high COFP accuracy. The agreement between COFP and COVS was -0.13 (0.69) L/min (Bland-Altman). In an exclusion zone of 12%, trending analysis found a 92% concordance between 5-minute changes in COFP and COVS. This study showed that CO can be reliably estimated using BPs and HR from the arterial BP waveform in combination with ML. A next step will be to test this approach using noninvasive BPs and HR.

  11. Protocol-driven remote monitoring of cardiac resynchronization therapy as part of a heart failure disease management strategy.

    Science.gov (United States)

    Smeets, Christophe J P; Verbrugge, Frederik H; Vranken, Julie; Van der Auwera, Jo; Mullens, Wilfried; Dupont, Matthias; Grieten, Lars; De Cannière, Hélène; Lanssens, Dorien; Vandenberk, Thijs; Storms, Valerie; Thijs, Inge M; Vandervoort, Pieter

    2017-08-14

    Cardiac resynchronisation therapy (CRT) is an established treatment for heart failure (HF) with reduced ejection fraction. CRT devices are equipped with remote monitoring functions, which are pivotal in the detection of device problems, but may also facilitate disease management. The aim of this study was to provide a comprehensive overview of the clinical interventions taken based on remote monitoring. This is a single centre observational study of consecutive CRT patients (n = 192) participating in protocol-driven remote follow-up. Incoming technical- and disease-related alerts were analysed together with subsequently triggered interventions. During 34 ± 13 months of follow-up, 1372 alert-containing notifications were received (2.53 per patient-year of follow-up), comprising 1696 unique alerts (3.12 per patient-year of follow-up). In 60%, notifications resulted in a phone contact. Technical alerts constituted 8% of incoming alerts (0.23 per patient-year of follow-up). Rhythm (1.43 per patient-year of follow-up) and bioimpedance alerts (0.98 per patient-year of follow-up) were the most frequent disease-related alerts. Notifications included a rhythm alert in 39%, which triggered referral to the emergency room (4%), outpatient cardiology clinic (36%) or general practitioner (7%), or resulted in medication changes (13%). Sole bioimpedance notifications resulted in a telephone contact in 91%, which triggered outpatient evaluation in 8% versus medication changes in 10%. Clinical outcome was excellent with 97% 1-year survival. Remote CRT follow-up resulted in 0.23 technical- versus 2.64 disease-related alerts annually. Rhythm and bioimpedance notifications constituted the majority of incoming notifications which triggered an actual intervention in 22% and 15% of cases, respectively.

  12. Remote Monitoring of the Heart Condition of Athletes by Measuring the Cardiac Action Potential Propagation Time Using a Wireless Sensor Network

    Directory of Open Access Journals (Sweden)

    Amang Sudarsono

    2016-04-01

    Full Text Available Highly performing athletes are susceptible to cardiac damage of several kinds which may be irreversible. The monitoring of heart rate and ECG waveforms from such subjects by wireless sensor networks has been reported in health and sports care documents. However, a more decisive parameter for instant to instant changes would be the time of Cardiac Action Potential Propagation. This time, which can be between 15-20 ms would shoot suddenly in acute stress in highly performing athletes for short durations. Repeated incidents of such rising values will tend to cause irreversible damage to the heart. We developed the technique of measuring this time and reporting it through a wireless sensor network to monitoring station.

  13. Monitoring cognitive and emotional processes through pupil and cardiac response during dynamic versus logical task.

    Science.gov (United States)

    Causse, Mickaël; Sénard, Jean-Michel; Démonet, Jean François; Pastor, Josette

    2010-06-01

    The paper deals with the links between physiological measurements and cognitive and emotional functioning. As long as the operator is a key agent in charge of complex systems, the definition of metrics able to predict his performance is a great challenge. The measurement of the physiological state is a very promising way but a very acute comprehension is required; in particular few studies compare autonomous nervous system reactivity according to specific cognitive processes during task performance and task related psychological stress is often ignored. We compared physiological parameters recorded on 24 healthy subjects facing two neuropsychological tasks: a dynamic task that require problem solving in a world that continually evolves over time and a logical task representative of cognitive processes performed by operators facing everyday problem solving. Results showed that the mean pupil diameter change was higher during the dynamic task; conversely, the heart rate was more elevated during the logical task. Finally, the systolic blood pressure seemed to be strongly sensitive to psychological stress. A better taking into account of the precise influence of a given cognitive activity and both workload and related task-induced psychological stress during task performance is a promising way to better monitor operators in complex working situations to detect mental overload or pejorative stress factor of error.

  14. Cardiac acceleration at the onset of exercise: a potential parameter for monitoring progress during physical training in sports and rehabilitation.

    Science.gov (United States)

    Hettinga, Florentina J; Monden, Paul G; van Meeteren, Nico L U; Daanen, Hein A M

    2014-05-01

    There is a need for easy-to-use methods to assess training progress in sports and rehabilitation research. The present review investigated whether cardiac acceleration at the onset of physical exercise (HRonset) can be used as a monitoring variable. The digital databases of Scopus and PubMed were searched to retrieve studies investigating HRonset. In total 652 studies were retrieved. These articles were then classified as having emphasis on HRonset in a sports or rehabilitation setting, which resulted in 8 of 112 studies with a sports application and 6 of 68 studies with a rehabilitation application that met inclusion criteria. Two co-existing mechanisms underlie HRonset: feedforward (central command) and feedback (mechanoreflex, metaboreflex, baroreflex) control. A number of studies investigated HRonset during the first few seconds of exercise (HRonsetshort), in which central command and the mechanoreflex determine vagal withdrawal, the major mechanism by which heart rate (HR) increases. In subsequent sports and rehabilitation studies, interest focused on HRonset during dynamic exercise over a longer period of time (HRonsetlong). Central command, mechanoreflexes, baroreflexes, and possibly metaboreflexes contribute to HRonset during the first seconds and minutes of exercise, which in turn leads to further vagal withdrawal and an increase in sympathetic activity. HRonset has been described as the increase in HR compared with resting state (delta HR) or by exponential modeling, with measurement intervals ranging from 0-4 s up to 2 min. Delta HR was used to evaluate HRonsetshort over the first 4 s of exercise, as well as for analyzing HRonsetlong. In exponential modeling, the HR response to dynamic exercise is biphasic, consisting of fast (parasympathetic, 0-10 s) and slow (sympathetic, 1-4 min) components. Although available studies differed largely in measurement protocols, cross-sectional and longitudinal training studies showed that studies analyzing HRonset

  15. Development of a Wearable Cardiac Monitoring System for Behavioral Neurocardiac Training: A Usability Study.

    Science.gov (United States)

    Uddin, Akib A; Morita, Plinio P; Tallevi, Kevin; Armour, Kevin; Li, John; Nolan, Robert P; Cafazzo, Joseph A

    2016-04-22

    Elevated blood pressure is one of the main risk factors for death globally. Behavioral neurocardiac training (BNT) is a complementary approach to blood pressure and stress management that is intended to exercise the autonomic reflexes, improve stress recovery, and lower blood pressure. BNT involves cognitive-behavioral therapy with a paced breathing technique and heart rate variability biofeedback. BNT is limited to in-clinic delivery and faces an accessibility barrier because of the need for clinical oversight and the use of complex monitoring tools. The objective of this project was to design, develop, and evaluate a wearable electrocardiographic (ECG) sensor system for the delivery of BNT in a home setting. The wearable sensor system, Beat, consists of an ECG sensor and a mobile app. It was developed iteratively using the principles of test-driven Agile development and user-centered design. A usability study was conducted at Toronto General Hospital to evaluate feasibility and user experience and identify areas of improvement. The Beat sensor was designed as a modular patch to be worn on the user's chest and uses standard ECG electrodes. It streams a single-lead ECG wirelessly to a mobile phone using Bluetooth Low Energy. The use of small, low-power electronics, a low device profile, and a tapered enclosure allowed for a device that can be unobtrusively worn under clothing. The sensor was designed to operate with a mobile app that guides users through the BNT exercises to train them to a slow-paced breathing technique for stress recovery. The BNT app uses the ECG captured by the sensor to provide heart rate variability biofeedback in the form of a real-time heart rate waveform to complement and reinforce the impact of the training. Usability testing (n=6) indicated that the overall response to the design and user experience of the system was perceived positively. All participants indicated that the system had a positive effect on stress management and that they

  16. Development of a Wearable Cardiac Monitoring System for Behavioral Neurocardiac Training: A Usability Study

    Science.gov (United States)

    Morita, Plinio P; Tallevi, Kevin; Armour, Kevin; Li, John; Nolan, Robert P; Cafazzo, Joseph A

    2016-01-01

    Background Elevated blood pressure is one of the main risk factors for death globally. Behavioral neurocardiac training (BNT) is a complementary approach to blood pressure and stress management that is intended to exercise the autonomic reflexes, improve stress recovery, and lower blood pressure. BNT involves cognitive-behavioral therapy with a paced breathing technique and heart rate variability biofeedback. BNT is limited to in-clinic delivery and faces an accessibility barrier because of the need for clinical oversight and the use of complex monitoring tools. Objective The objective of this project was to design, develop, and evaluate a wearable electrocardiographic (ECG) sensor system for the delivery of BNT in a home setting. Methods The wearable sensor system, Beat, consists of an ECG sensor and a mobile app. It was developed iteratively using the principles of test-driven Agile development and user-centered design. A usability study was conducted at Toronto General Hospital to evaluate feasibility and user experience and identify areas of improvement. Results The Beatsensor was designed as a modular patch to be worn on the user’s chest and uses standard ECG electrodes. It streams a single-lead ECG wirelessly to a mobile phone using Bluetooth Low Energy. The use of small, low-power electronics, a low device profile, and a tapered enclosure allowed for a device that can be unobtrusively worn under clothing. The sensor was designed to operate with a mobile app that guides users through the BNT exercises to train them to a slow-paced breathing technique for stress recovery. The BNT app uses the ECG captured by the sensor to provide heart rate variability biofeedback in the form of a real-time heart rate waveform to complement and reinforce the impact of the training. Usability testing (n=6) indicated that the overall response to the design and user experience of the system was perceived positively. All participants indicated that the system had a positive

  17. The optimal hemodynamics management of post-cardiac arrest shock.

    Science.gov (United States)

    Pellis, Tommaso; Sanfilippo, Filippo; Ristagno, Giuseppe

    2015-12-01

    Patients resuscitated from cardiac arrest develop a pathophysiological state named "post-cardiac arrest syndrome." Post-resuscitation myocardial dysfunction is a common feature of this syndrome, and many patients eventually die from cardiovascular failure. Cardiogenic shock accounts for most deaths in the first 3 days, when post-resuscitation myocardial dysfunction peaks. Thus, identification and treatment of cardiovascular failure is one of the key therapeutic goals during hospitalization of post-cardiac arrest patients. Patients with hemodynamic instability may require advanced cardiac output monitoring. Inotropes and vasopressors should be considered if hemodynamic goals are not achieved despite optimized preload. If these measures fail to restore adequate organ perfusion, a mechanical circulatory assistance device may be considered. Adequate organ perfusion should be ensured in the absence of definitive data on the optimal target pressure goals. Hemodynamic goals should also take into account targeted temperature management and its effect on the cardiovascular function. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Intraoperative TTE inferior vena cava monitoring in elderly orthopaedic patients with cardiac disease and spinal-induced hypotension.

    Science.gov (United States)

    Saranteas, Theodosios; Manikis, Dimitrios; Papadimos, Thomas; Mavrogenis, Andreas F; Kostopanagiotou, Georgia; Panou, Fotios

    2017-10-01

    Objective To address the role of transthoracic echocardiography in inferior vena cava (IVC) monitoring in the management of haemodynamically unstable elderly patients subjected to lower limb orthopaedic surgery under spinal anesthesia. Possible implications in the postoperative care unit (PACU) length of stay (LOS) are investigated. Methods 41 elderly patients with cardiac diseases were recruited. Patients experiencing intraoperative haemodynamic instability (diastolic blood pressure ≤ 60 mmHg) were divided into two groups according to right atrial pressure (RAP), (RAP < 5 mmHg and RAP between 5 and 10 mmHg) as measured by inferior vena cava collapsibility index (IVCCI). Haemodynamic instability was treated with normal saline infused at a constant rate supplemented by phenylephrine (PHE) infusions titrated to normal blood pressure values. Intraoperatively comparisons of peak PHE infusion rates and all episodes of hypotension, including in the PACU, were recorded among groups. The patients' PACU LOS and associated factors were assessed. Results The intraoperative peak PHE infusion rate and the incidence of haemodynamic instability in the postoperative period were significantly higher in patients with RAP < 5 mmHg. The total PHE consumption was also higher in patients with RAP < 5 mmHg postoperatively. The primary risk factor for a prolonged stay in PACU, as determined by multiple regression analysis was RAP. Conclusions Patients with high dynamic collapsibility of the IVC may require aggressive treatment to restore their haemodynamic status. Additionally, intraoperative levels of RAP, as measured by IVCCI, can act as a predictor for increased LOS in the PACU.

  19. Self-monitoring for atrial fibrillation recurrence in the discharge period post-cardiac surgery using an iPhone electrocardiogram.

    Science.gov (United States)

    Lowres, Nicole; Mulcahy, Georgina; Gallagher, Robyn; Ben Freedman, Saul; Marshman, David; Kirkness, Ann; Orchard, Jessica; Neubeck, Lis

    2016-07-01

    Postoperative atrial fibrillation (POAF) occurs in 25-40% of patients following cardiac surgery, and is associated with a significant increased risk of stroke and mortality. Routine surveillance is not performed post-discharge; however, recurrence of POAF can occur in up to 30% of patients discharged in sinus rhythm. This study aimed to determine the feasibility of patients self-monitoring with an iPhone handheld electrocardiogram (iECG) to identify recurrence of POAF in the post-discharge period following cardiac surgery. Patients with POAF following cardiac surgery were eligible for participation if they had no prior history of atrial fibrillation (AF) and were discharged home in stable sinus rhythm. Participants were provided with an iECG and asked to record a 30-s iECG, four times per day for 4 weeks post-discharge. iECGs were automatically transmitted to a secure server, and reviewed for the presence of AF by the research team and a validated algorithm. All participants also received brief education on AF. Forty-two participants completed the intervention (mean age 69 ± 9 years, 80% male). Self-monitoring for POAF recurrence using an iECG was feasible and acceptable, and participants felt empowered. Self-monitoring identified 24% (95% confidence interval, 12-39%) with an AF recurrence within 17 days of hospital discharge. These participants were significantly younger than those without AF recurrence (64 ± 7 vs 70 ± 10 years; P = 0.025), and had a significantly lower CHA2DS2-VASc score (2.3 ± 1.2 vs 3.7 ± 2.3; P = 0.007). However, 80% were at high enough stroke risk to warrant consideration of anticoagulation, i.e. CHA2DS2-VASc score ≥2. Only 30% of recurrences were associated with palpitations. Participation also improved AF knowledge from 6.4 ± 1.8 to 7.3 ± 1.8 (P = 0.02), of a total score of 10. Providing patients with an iECG is a non-invasive, inexpensive, convenient and feasible way to monitor for AF recurrence in post-cardiac surgery patients

  20. Implementation and reimbursement of remote monitoring for cardiac implantable electronic devices in Europe: a survey from the health economics committee of the European Heart Rhythm Association.

    Science.gov (United States)

    Mairesse, Georges H; Braunschweig, Frieder; Klersy, Katherine; Cowie, Martin R; Leyva, Francisco

    2015-05-01

    Remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) permits early detection of arrhythmias, device, and lead failure and may also be useful in risk-predicting patient-related outcomes. Financial benefits for patients and healthcare organizations have also been shown. We sought to assess the implementation and funding of RM of CIEDs, including conventional pacemakers (PMs), implantable cardioverter defibrillators (ICDs), and cardiac resynchronization therapy (CRT) devices in Europe. Electronic survey from 43 centres in 15 European countries. In the study sample, RM was available in 22% of PM patients, 74% of ICD patients, and 69% of CRT patients. The most significant perceived benefits were the early detection of atrial arrhythmias in pacemaker patients, lead failure in ICD patients, and worsening heart failure in CRT patients. Remote monitoring was reported to lead a reduction of in-office follow-ups for all devices. The most important reported barrier to the implementation of RM for all CIEDs was lack of reimbursement (80% of centres). Physicians regard RM of CIEDs as a clinically useful technology that affords significant benefits for patients and healthcare organizations. Remote monitoring, however, is perceived as increasing workload. Reimbursement for RM is generally perceived as a major barrier to implementation. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  1. Safety in cardiac surgery

    NARCIS (Netherlands)

    Siregar, S.

    2013-01-01

    The monitoring of safety in cardiac surgery is a complex process, which involves many clinical, practical, methodological and statistical issues. The objective of this thesis was to measure and to compare safety in cardiac surgery in The Netherlands using the Netherlands Association for

  2. [Advances in cardiac pacing].

    Science.gov (United States)

    de Carranza, María-José Sancho-Tello; Fidalgo-Andrés, María Luisa; Ferrer, José Martínez; Mateas, Francisco Ruiz

    2012-01-01

    This article contains a review of the current status of remote monitoring and follow-up involving cardiac pacing devices and of the latest developments in cardiac resynchronization therapy. In addition, the most important articles published in the last year are discussed. Copyright © 2012 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  3. Cardiopulmonary stress testing using ambulatory radionuclide monitoring system: The relationship between vascular endothelial function and cardiac response in patients with ischemic heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Akima, Takashi; Tabata, Hirotsugu [Self-Defense Forces Central Hospital, Tokyo (Japan); Takase, Bonpei [National Defense Medical Coll., Tokorozawa, Saitama (Japan)] [and others

    2002-02-01

    The relationship in the title was studied with a new type ambulatory radionuclide monitoring system. Subjects were 12 male patients with ischemic heart diseases. After cardiac scintigraphy at rest of {sup 99m}Tc-human serum albumin (740 MBq) with GE Mirenium, patients wore the C-VEST jacket (Capintec medset cardiolight), which consisted from 2 radioactivity detectors and Holter ECG recorder, and underwent the cardiopulmonary stress testing with Treadmill Ramp exercise to evaluate the anaerobic threshold (AT), VO{sub 2}, left ventricular ejection flow (EF) and stroke volume (SV). Vascular endothelial function was recorded by ultrasonography of brachial artery by monitoring the flow-mediated dilation (FD). Mean EF at rest was 56% and there was no relationship between VO{sub 2} at rest or exercise and FD. However, the relationship between FD and change of SV or EF from rest to AT was recognized and thus FD was suggested to participate in cardiac function change at exercise of those patients. (K.H.)

  4. Aminoterminal Pro B-Type Natriuretic Peptide (NT-proBNP Levels for Monitoring Interventions in Paediatric Cardiac Patients with Stenotic Lesions

    Directory of Open Access Journals (Sweden)

    Eva Welisch

    2009-01-01

    Full Text Available Background. Serum concentration of NT-proBNP correlates well with the severity of cardiac disease in adults. Few studies have been performed on the applicability of NT-proBNP for monitoring children with congenital heart disease. Objective. To assess the potential of NT-proBNP for monitoring the success of interventions in children with stenotic cardiac lesions. Methods. NT-proBNP was measured in 42 children aged 1 day to 17 years (y before and 6 to 12 weeks after surgical or interventional correction of obstructive lesions of the heart. Comparison is made with the clinical status and echocardiographic data of the child. Results. NT-proBNP levels (median 280, range 10–263,000 pg/mL were above the reference value in all but 6 patients (pts prior to the intervention. Higher levels were found in more compromised patients. The 35 children with clinical improvement after the procedure showed a decline of their NT-proBNP level in all but 4 patients, whose levels remained unchanged. Five patients with unchanged gradients despite a therapeutic intervention also demonstrated unchanged NT-proBNP levels after the intervention. Thus, the success rate of the procedure correlated well to clinical and echocardiographic findings. Conclusion. NT-proBNP can be used to assess the efficiency of an intervention.

  5. Implantable cardiac monitors in high-risk post-infarction patients with cardiac autonomic dysfunction and moderately reduced left ventricular ejection fraction: Design and rationale of the SMART-MI trial.

    Science.gov (United States)

    Hamm, Wolfgang; Rizas, Konstantinos D; Stülpnagel, Lukas von; Vdovin, Nikolay; Massberg, Steffen; Kääb, Stefan; Bauer, Axel

    2017-08-01

    Most deaths after myocardial infarction (MI) occur in patients with left ventricular ejection fraction (LVEF) >35%, for whom no specific prophylactic strategies exist. Deceleration capacity (DC) of heart rate and periodic repolarization dynamics (PRD) are noninvasive electrophysiological markers depending on the vagal and sympathetic tone. The combination of abnormal DC and/or PRD identifies a new high-risk group among postinfarction patients with LVEF 36%-50%. This new high-risk group has similar characteristics with respect to prognosis and patient numbers to those of the established high-risk group identified by LVEF ≤ 35%. The SMART-MI trial is an investigator-initiated randomized prospective multicenter trial that tests the efficacy of implantable cardiac monitors (ICM) in this new high-risk group. The study will enroll approximately 1,600 survivors of acute MI with sinus rhythm and an LVEF of 35%-50% in 17 centers in Germany who will be tested for presence of cardiac autonomic dysfunction. Four hundred patients with either abnormal DC (≤2.5 ms) and/or PRD (≥5.75deg 2 ) will be randomized in a 1:1 fashion to intensive follow-up via telemonitoring using an ICM device (experimental arm) or conventional follow-up (control arm). For the ICM arm, specific treatment paths have been developed according to current guidelines. The primary end point is time to detection of predefined serious arrhythmic events during follow-up, including atrial fibrillation ≥6minutes, nonsustained ventricular tachycardia (cycle length≤320 ms; ≥40 beats), atrioventricular block ≥IIb, and sustained ventricular tachycardia/ventricular fibrillation. The median follow-up period is 18months with a minimum follow-up of 6months. The effect of remote monitoring on clinical outcomes will be tested as secondary outcome measure (ClinicalTrials.gov NCT02594488). Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Testing and Evaluation of the Medical Research Laboratories, Inc., 360SLX Cardiac Monitor/Pacemaker/Defibrillator System

    National Research Council Canada - National Science Library

    Hade, Edward

    1998-01-01

    The Medical Research Laboratories (MRL), Inc., model 360 SLx is a portable cardica monitor, defibrillator, and pacemaker that offers synchronized defibrillator, electrocardiogram monitoring, and non-invasive temporary pacing...

  7. Regulation of Cardiac Hypertrophy: the nuclear option

    NARCIS (Netherlands)

    D.W.D. Kuster (Diederik)

    2011-01-01

    textabstractCardiac hypertrophy is the response of the heart to an increased workload. After myocardial infarction (MI) the surviving muscle tissue has to work harder to maintain cardiac output. This sustained increase in workload leads to cardiac hypertrophy. Despite its apparent appropriateness,

  8. Diabetes Mellitus, Microalbuminuria, and Subclinical Cardiac Disease: Identification and Monitoring of Individuals at Risk of Heart Failure.

    Science.gov (United States)

    Swoboda, Peter P; McDiarmid, Adam K; Erhayiem, Bara; Ripley, David P; Dobson, Laura E; Garg, Pankaj; Musa, Tarique A; Witte, Klaus K; Kearney, Mark T; Barth, Julian H; Ajjan, Ramzi; Greenwood, John P; Plein, Sven

    2017-07-17

    Patients with type 2 diabetes mellitus and elevated urinary albumin:creatinine ratio (ACR) have increased risk of heart failure. We hypothesized this was because of cardiac tissue changes rather than silent coronary artery disease. In a case-controlled observational study 130 subjects including 50 ACR+ve diabetes mellitus patients with persistent microalbuminuria (ACR >2.5 mg/mol in males and >3.5 mg/mol in females, ≥2 measurements, no previous renin-angiotensin-aldosterone therapy, 50 ACR-ve diabetes mellitus patients and 30 controls underwent cardiovascular magnetic resonance for investigation of myocardial fibrosis, ischemia and infarction, and echocardiography. Thirty ACR+ve patients underwent further testing after 1-year treatment with renin-angiotensin-aldosterone blockade. Cardiac extracellular volume fraction, a measure of diffuse fibrosis, was higher in diabetes mellitus patients than controls (26.1±3.4% and 23.3±3.0% P =0.0002) and in ACR+ve than ACR-ve diabetes mellitus patients (27.2±4.1% versus 25.1±2.9%, P =0.004). ACR+ve patients also had lower E' measured by echocardiography (8.2±1.9 cm/s versus 8.9±1.9 cm/s, P =0.04) and elevated high-sensitivity cardiac troponin T 18% versus 4% ≥14 ng/L ( P =0.05). Rate of silent myocardial ischemia or infarction were not influenced by ACR status. Renin-angiotensin-aldosterone blockade was associated with increased left ventricular ejection fraction (59.3±7.8 to 61.5±8.7%, P =0.03) and decreased extracellular volume fraction (26.5±3.6 to 25.2±3.1, P =0.01) but no changes in diastolic function or high-sensitivity cardiac troponin T levels. Asymptomatic diabetes mellitus patients with persistent microalbuminuria have markers of diffuse cardiac fibrosis including elevated extracellular volume fraction, high-sensitivity cardiac troponin T, and diastolic dysfunction, which may in part be reversible by renin-angiotensin-aldosterone blockade. Increased risk in these patients may be mediated by

  9. Echocardiographic guidance and monitoring of left atrial appendage closure with AtriClip during open-chest cardiac surgery.

    Science.gov (United States)

    Contri, Rachele; Clivio, Sara; Torre, Tiziano; Cassina, Tiziano

    2017-10-01

    Left atrial appendage (LAA) closure prevents thromboembolic risk and avoids lifelong anticoagulation due to atrial fibrillation (AF). Nowadays, AtriClip, a modern epicardial device approved in June 2010, allows external and safe closure of LAA in patients undergoing cardiac surgery during other open-chest cardiac surgical procedures. Such a surgical approach and its epicardial deployment differentiates LAA closure with AtriClip from percutaneous closure techniques such as Watchman (Boston Scientific, Marlborough, MA, USA), Lariat (SentreHEART Inc., Redwood City, CA, USA), and Amplatzer Amulet (St. Jude Medical, St. Paul, MN, USA) device procedures. AtriClip positioning must consider perioperative transesophageal echocardiography (TEE) to confirm LAA anatomical features, to explore the links with neighboring structures, and finally to assess its successful closure. We report a sequence of images to document the role of intraoperative TEE during an elective aortic valve replacement and LAA external closure with AtriClip. © 2017, Wiley Periodicals, Inc.

  10. Prevalence of nursing diagnosis of decreased cardiac output and the predictive value of defining characteristics in patients under evaluation for heart transplant Prevalencia del diagnóstico de enfermería de disminución del gasto cardíaco y valor predictivo de las características definidoras en pacientes en fase de evaluación para trasplante cardíaco Prevalência do diagnóstico de enfermagem de débito cardíaco diminuído e valor preditivo das características definidoras em pacientes em avaliação para transplante cardíaco

    OpenAIRE

    Lígia Neres Matos; Tereza Cristina Felippe Guimarães; Marcos Antônio Gomes Brandão; Deyse Conceição Santoro

    2012-01-01

    The purposes of the study were to identify the prevalence of defining characteristics (DC) of decreased cardiac output (DCO) in patients with cardiac insufficiency under evaluation for heart transplantation, and to ascertain the likelihood of defining characteristics being predictive factors for the existence of reduction in cardiac output. Data was obtained by retrospective documental analysis of the clinical records of right-sided heart catheterizations in 38 patients between 2004 and 2009....

  11. Unit 16 - Output

    OpenAIRE

    Unit 16, CC in GIS; Star, Jeffrey L.

    1990-01-01

    This unit discusses issues related to GIS output, including the different types of output possible and the hardware for producing each. It describes text, graphic and digital data that can be generated by a GIS as well as line printers, dot matrix printers/plotters, pen plotters, optical scanners and cathode ray tubes (CRTs) as technologies for generating the output.

  12. Cerebral monitoring during neonatal surgery for non-cardiac congenital anomalies: a first step to improve outcome?

    NARCIS (Netherlands)

    Stolwijk, L.J.

    2017-01-01

    Monitoring the newborn brain during surgery Cerebral monitoring in newborns, who require surgery in the first month of life, is important to protect the brain. The newborn brain is vulnerable during neonatal surgery. Newborn babies with a congenital anomaly requiring surgery in the first month of

  13. Responders and nonresponders after catheter ablation procedure and antiarrhythmic drug therapy in patients with paroxysmal AF: data from implantable cardiac monitors

    Directory of Open Access Journals (Sweden)

    А. А. Симонян

    2016-11-01

    Full Text Available Aim. The aim of this study was to assess the number of responders and nonresponders after catheter ablation procedure and antiarrhythmic drug therapy (AAD in patients with paroxysmal AF through implantable cardiac monitors (ICM. Methods. 92 patients with paroxysmal AF were randomized into two groups: 1 AAD + ICM implantation (group I; n=46, and 2 AF catheter ablation (CA + ICM implantation (group II; n=46, and 2. Patients with an AF% < 0.5% were considered AF-free (responders. Patients with AF% > 0.5% were classified as nonresponders. The follow up of this study was 24 months.Results. At the end of the follow-up period 13 (28.3% patients in AAD group and 29 (63 % patients in CA group were responders (log-rank test; р=0.0009; HR 2,6; 95% CI [1.44-4.69], р=0.001, Cox regression. According to multivariate logistic regression analysis data, AF burden>4.5% during the first two months after treatment (odds ratio [OR]=38,9; 95% confidence interval [CI], 6.2–245; P<0.001, arterial hypertension (OR=12.7; 95% CI, 1.9–85.3; P=0.009 and AF duration more than 5 years (OR=8.5; 95% CI, 1.04–69.6; P=0.044 were independent predictors of AF burden progression Conclusion. According to implantable cardiac monitors data, in patients with paroxysmal AF radiofrequency catheter ablation as compared to antiarrhythmic drug therapy results in higher percentage of responders.Received 10 July 2016. Accepted 22 August 2016.Funding: The study had no sponsorship. Conflict of interest: The authors declare no conflict of interest.

  14. External cardiac compression may be harmful in some scenarios of pulseless electrical activity.

    LENUS (Irish Health Repository)

    Hogan, T S

    2012-10-01

    Pulseless electrical activity occurs when organised or semi-organised electrical activity of the heart persists but the product of systemic vascular resistance and the increase in systemic arterial flow generated by the ejection of the left venticular stroke volume is not sufficient to produce a clinically detectable pulse. Pulseless electrical activity encompasses a very heterogeneous variety of severe circulatory shock states ranging in severity from pseudo-cardiac arrest to effective cardiac arrest. Outcomes of cardiopulmonary resuscitation for pulseless electrical activity are generally poor. Impairment of cardiac filling is the limiting factor to cardiac output in many scenarios of pulseless electrical activity, including extreme vasodilatory shock states. There is no evidence that external cardiac compression can increase cardiac output when impaired cardiac filling is the limiting factor to cardiac output. If impaired cardiac filling is the limiting factor to cardiac output and the heart is effectively ejecting all the blood returning to it, then external cardiac compression can only increase cardiac output if it increases venous return and cardiac filling. Repeated cardiac compression asynchronous with the patient\\'s cardiac cycle and raised mean intrathoracic pressure due to chest compression can be expected to reduce rather than to increase cardiac filling and therefore to reduce rather than to increase cardiac output in such circumstances. The hypothesis is proposed that the performance of external cardiac compression will have zero or negative effect on cardiac output in pulseless electrical activity when impaired cardiac filling is the limiting factor to cardiac output. External cardiac compression may be both directly and indirectly harmful to significant sub-groups of patients with pulseless electrical activity. We have neither evidence nor theory to provide comfort that external cardiac compression is not harmful in many scenarios of pulseless

  15. External cardiac compression may be harmful in some scenarios of pulseless electrical activity.

    Science.gov (United States)

    Hogan, T S

    2012-10-01

    Pulseless electrical activity occurs when organised or semi-organised electrical activity of the heart persists but the product of systemic vascular resistance and the increase in systemic arterial flow generated by the ejection of the left venticular stroke volume is not sufficient to produce a clinically detectable pulse. Pulseless electrical activity encompasses a very heterogeneous variety of severe circulatory shock states ranging in severity from pseudo-cardiac arrest to effective cardiac arrest. Outcomes of cardiopulmonary resuscitation for pulseless electrical activity are generally poor. Impairment of cardiac filling is the limiting factor to cardiac output in many scenarios of pulseless electrical activity, including extreme vasodilatory shock states. There is no evidence that external cardiac compression can increase cardiac output when impaired cardiac filling is the limiting factor to cardiac output. If impaired cardiac filling is the limiting factor to cardiac output and the heart is effectively ejecting all the blood returning to it, then external cardiac compression can only increase cardiac output if it increases venous return and cardiac filling. Repeated cardiac compression asynchronous with the patient's cardiac cycle and raised mean intrathoracic pressure due to chest compression can be expected to reduce rather than to increase cardiac filling and therefore to reduce rather than to increase cardiac output in such circumstances. The hypothesis is proposed that the performance of external cardiac compression will have zero or negative effect on cardiac output in pulseless electrical activity when impaired cardiac filling is the limiting factor to cardiac output. External cardiac compression may be both directly and indirectly harmful to significant sub-groups of patients with pulseless electrical activity. We have neither evidence nor theory to provide comfort that external cardiac compression is not harmful in many scenarios of pulseless

  16. Effects of Reservoir Filling on Sediment and Nutrient Removal in the Lower Susquehanna River Reservoir: An Input-Output Analysis Based on Long-Term Monitoring

    Science.gov (United States)

    Ball, W. P.; Zhang, Q.; Hirsch, R. M.

    2015-12-01

    Reduction of suspended sediment (SS), total phosphorus (TP), and total nitrogen is an important focus for Chesapeake Bay watershed management. Susquehanna River, the bay's largest tributary, has drawn attention because SS load from behind Conowingo Dam (near the river fall-line) has risen dramatically recently. To better understand these changes, we evaluated decadal-scale (1986-2013) history of concentrations and fluxes using data from sites above and below the reservoir. First, observed concentration-discharge relationships show declined SS and TP concentrations at the reservoir inlet under most discharges in recent years, but such changes have not been propagated to emerge at the outlet, implying recently diminished reservoir trapping. Second, best estimates of loadings show declined net depositions of SS and TP in recent decades, which occurred under a range of discharges, with the 75th~99.5th percentile of Conowingo discharge dominating such changes and carrying most sediment/nutrient loadings. Finally, stationary models that better accommodate effects of riverflow variability also show diminished reservoir trapping of SS and TP, which occurred under a range of flows including those well below the literature-documented scour threshold. These findings have significant implications in regard to our understanding and management of this major reservoir and illustrate the value of long-term monitoring programs.

  17. Pre-hospital portable monitoring of cerebral regional oxygen saturation (rSO2) in seven patients with out-of-hospital cardiac arrest.

    Science.gov (United States)

    Hirose, Tomoya; Shiozaki, Tadahiko; Nomura, Junji; Hamada, Yasuto; Sato, Keiichi; Katsura, Kazuya; Ehara, Naoki; Wakai, Akinori; Shimizu, Kentaro; Ohnishi, Mitsuo; Hayashida, Sumito; Sadamitsu, Daikai; Shimazu, Takeshi

    2016-08-31

    In recent years, measurement of cerebral regional oxygen saturation (rSO2) has attracted attention during resuscitation. However, serial changes of cerebral rSO2 in pre-hospital settings are unclear. The objective of this study was to clarify serial changes in cerebral rSO2 of patients with out-of-hospital cardiac arrest (OHCA) in the pre-hospital setting. We recently developed a portable rSO2 monitor that is small (170 × 100 × 50 mm in size and 600 g in weight) enough to carry in pre-hospital settings. The sensor is attached to the patient's forehead by the ELT (Emergency Life-saving Technician), and it monitors rSO2 continuously. From June 2013 through August 2014, serial changes in cerebral rSO2 in seven patients were evaluated. According to the results of the serial changes in rSO2, four patterns of rSO2 change were found, as follows. Type 1: High rSO2 (around about 60 %) type (n = 1). Initial electrocardiogram was ventricular fibrillation and ROSC (return of spontaneous circulation) could be diagnosed in pre-hospital setting. Her outcome at discharge was Good Recovery (GR). Type 2: Low rSO2 (around about 45-50 %) type (n = 3). They did not get ROSC even once. Type 3: Gradually decreasing rSO2 type (n = 2): ROSC could be diagnosed in hospital, but not in pre-hospital setting. Their outcomes at discharge were not GR. Type 4: other type (n = 1). In this patient with ROSC when ELT started cerebral rSO2 measurement, cerebral rSO2 was 67.3 % at measurement start, it dropped gradually to 54.5 %, and then rose to 74.3 %. The cerebral oxygenation was impaired due to possible cardiac arrest again, and after that, ROSC led to the recovery of cerebral blood flow. We could measure serial changes in cerebral rSO2 in seven patients with OHCA in the pre-hospital setting. Our data suggest that pre-hospital monitoring of cerebral rSO2 might lead to a new resuscitation strategy.

  18. Feasibility and Acceptability of Utilizing a Smartphone Based Application to Monitor Outpatient Discharge Instruction Compliance in Cardiac Disease Patients around Discharge from Hospitalization

    Directory of Open Access Journals (Sweden)

    Aimee M. Layton

    2014-01-01

    Full Text Available The purpose of this study was to determine the feasibility and acceptability of utilizing a smartphone based application to monitor compliance in patients with cardiac disease around discharge. For 60 days after discharge, patients’ medication compliance, physical activity, follow-up care, symptoms, and reading of education material were monitored daily with the application. 16 patients were enrolled in the study (12 males, 4 females, age 55 ± 18 years during their hospital stay. Five participants were rehospitalized during the study and did not use the application once discharged. Seven participants completed 1–30 days and four patients completed >31 days. For those 11 patients, medication reminders were utilized 37% (1–30-day group and 53% (>31-day group of the time, education material was read 44% (1–30 and 53% (>31 of the time, and physical activity was reported 25% (1–30 and 42% (>31 of the time. Findings demonstrated that patients with stable health utilized the application, even if only minimally. Patients with decreased breath sounds by physical exam and who reported their health as fair to poor on the day of discharge were less likely to utilize the application. Acceptability of the application to report health status varied among the stable patients.

  19. Validation of the concept Risk for Decreased Cardiac Output Validación del concepto riesgo de débito cardiaco disminuido Validação do conceito risco de débito cardíaco diminuído

    Directory of Open Access Journals (Sweden)

    Eduarda Ribeiro dos Santos

    2013-02-01

    Full Text Available OBJECTIVES: to validate the concept "risk for decreased cardiac output". METHOD: Six of the eight steps suggested in the technique developed by Walker & Avant were adopted to analyze the concept of the phenomenon under study and the proposal made by Hoskins was used for content validation, taking into account agreement achieved among five experts. RESULTS: the concept "decreased cardiac output" was found in the nursing and medical fields and refers to the heart's pumping capacity while the concept "risk" is found in a large number of disciplines. In regard to the defining attributes, "impaired pumping capacity" was the main attribute of decreased cardiac output and "probability" was the main attribute of risk. The uses and defining attributes of the concepts "decreased cardiac output" and "risk" were analyzed as well as their antecedent and consequent events in order to establish the definition of "risk for decreased cardiac output", which was validated by 100% of the experts. CONCLUSION: The obtained data indicate that the risk for decreased cardiac output phenomenon can be a nursing diagnosis and refining it can contribute to the advancement of nursing classifications in this context.OBJETIVO: Validar el concepto riesgo del débito cardíaco disminuido. MÉTODO: Fue adoptada la técnica de Walker & Avant para analizar la definición del fenómeno enfocado, utilizando seis de las ocho etapas sugeridas y la propuesta de Hoskins para validar el contenido, considerándose la conformidad entre cinco expertos. RESULTADOS: el concepto de debito cardíaco disminuido se encuentra en las áreas enfermería y médica y su atención se centra en la capacidad de bombeo del corazón. Sin embargo, el concepto de riesgo es presente en un gran número de áreas. Las características definitorias de la disminución del gasto cardíaco mostraron como principal atributo deficiencia de la bomba cardiaca y, para el riesgo, el atributo de probabilidad. Analizados

  20. A Submaximal Running Test With Post-Exercise Cardiac Autonomic And Neuromuscular Function In Monitoring Endurance Training Adaptation

    OpenAIRE

    Vesterinen, Ville; Nummela, Ari; Laine, Tanja; Hynynen, Esa; Mikkola, Jussi; Häkkinen, Keijo

    2016-01-01

    The aim of this study was to investigate whether a submaximal running test (SRT) with postexercise heart rate recovery (HRR), heart rate variability (HRV), and countermovement jump (CMJ) measurements could be used to monitor endurance training adaptation. Thirty-five endurance-trained men and women completed an 18-week endurance training. Maximal endurance performance and maximal oxygen uptake were measured every 8 weeks. In addition, SRTs with postexercise HRR, HRV, and CMJ measurements were...

  1. A low-power and miniaturized electrocardiograph data collection system with smart textile electrodes for monitoring of cardiac function.

    Science.gov (United States)

    Dai, Ming; Xiao, Xueliang; Chen, Xin; Lin, Haoming; Wu, Wanqing; Chen, Siping

    2016-12-01

    With the increasing aging population as well as health concerns, chronic heart disease has become the focus of public attention. A comfortable, low-powered, and wearable electrocardiogram (ECG) system for continuously monitoring the elderly's ECG signals over several hours is important for preventing cardiovascular diseases. Traditional ECG monitoring apparatus is often inconvenient to carry, has many electrodes to attach to the chest, and has a high-power consumption. There is also a challenge to design an electrocardiograph that satisfies requirements such as comfort, confinement, and compactness. Based on these considerations, this study presents a biosensor acquisition system for wearable, ubiquitous healthcare applications using three textile electrodes and a recording circuit specialized for ECG monitoring. In addition, several methods were adopted to reduce the power consumption of the device. The proposed system is composed of three parts: (1) an ECG analog front end (AFE), (2) digital signal processing and micro-control circuits, and (3) system software. Digital filter methods were used to eliminate the baseline wander, skin contact noise, and other interfering signals. A comparative study was conducted using this system to observe its performance with two commercial Holter monitors. The experimental results demonstrated that the total power consumption of this proposed system in a full round of ECG acquisition was only 29.74 mW. In addition, this low-power system performed well and stably measured the heart rate with an accuracy of 98.55 %. It can also contain a real-time dynamic display with organic light-emitting diodes (OLED) and wirelessly transmit information via a Bluetooth 4.0 module.

  2. Pediatric cardiac postoperative care

    Directory of Open Access Journals (Sweden)

    Auler Jr. José Otávio Costa

    2002-01-01

    Full Text Available The Heart Institute of the University of São Paulo, Medical School is a referral center for the treatment of congenital heart diseases of neonates and infants. In the recent years, the excellent surgical results obtained in our institution may be in part due to modern anesthetic care and to postoperative care based on well-structured protocols. The purpose of this article is to review unique aspects of neonate cardiovascular physiology, the impact of extracorporeal circulation on postoperative evolution, and the prescription for pharmacological support of acute cardiac dysfunction based on our cardiac unit protocols. The main causes of low cardiac output after surgical correction of heart congenital disease are reviewed, and methods of treatment and support are proposed as derived from the relevant literature and our protocols.

  3. Cardiac rehabilitation

    Science.gov (United States)

    ... rehab; Heart failure - cardiac rehab References Anderson L, Taylor RS. Cardiac rehabilitation for people with heart disease: ... of Medicine, Division of Cardiology, Harborview Medical Center, University of Washington Medical School, Seattle, WA. Also reviewed ...

  4. Sensing Cardiac Electrical Activity With a Cardiac Myocyte--Targeted Optogenetic Voltage Indicator

    NARCIS (Netherlands)

    Chang Liao, Mei-Ling; de Boer, Teun P|info:eu-repo/dai/nl/30481878X; Mutoh, Hiroki; Raad, Nour; Richter, Claudia; Wagner, Eva; Downie, Bryan R; Unsöld, Bernhard; Arooj, Iqra; Streckfuss-Bömeke, Katrin; Döker, Stephan; Luther, Stefan; Guan, Kaomei; Wagner, Stefan; Lehnart, Stephan E; Maier, Lars S; Stühmer, Walter; Wettwer, Erich; van Veen, Toon|info:eu-repo/dai/nl/229701310; Morlock, Michael M; Knöpfel, Thomas; Zimmermann, Wolfram-Hubertus

    2015-01-01

    RATIONALE: Monitoring and controlling cardiac myocyte activity with optogenetic tools offer exciting possibilities for fundamental and translational cardiovascular research. Genetically encoded voltage indicators may be particularly attractive for minimal invasive and repeated assessments of cardiac

  5. Output hardcopy devices

    CERN Document Server

    Durbeck, Robert

    1988-01-01

    Output Hardcopy Devices provides a technical summary of computer output hardcopy devices such as plotters, computer output printers, and CRT generated hardcopy. Important related technical areas such as papers, ribbons and inks, color techniques, controllers, and character fonts are also covered. Emphasis is on techniques primarily associated with printing, as well as the plotting capabilities of printing devices that can be effectively used for computer graphics in addition to their various printing functions. Comprised of 19 chapters, this volume begins with an introduction to vector and ras

  6. CMAQ Model Output

    Data.gov (United States)

    U.S. Environmental Protection Agency — CMAQ and CMAQ-VBS model output. This dataset is not publicly accessible because: Files too large. It can be accessed through the following means: via EPA's NCC tape...

  7. WRF Model Output

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset contains WRF model output. There are three months of data: July 2012, July 2013, and January 2013. For each month, several simulations were made: A...

  8. VMS forms Output Tables

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These output tables contain parsed and format validated data from the various VMS forms that are sent from any given vessel, while at sea, from the VMS devices on...

  9. ?Healthcare IoT m-GreenCARDIO Remote Cardiac Monitoring System - Concept, Theory of Operation and Implementation

    Directory of Open Access Journals (Sweden)

    ZAGAN, I.

    2017-05-01

    Full Text Available Present day Internet of Things (IoT developers are inspired by the spectacular evolution in the field, and, at the same time, determined to connect an increasingly wider range of 'things', with the lowest power consumption, the wider range of action and interoperability guaranteed with excessive quality. Based on current challenges in the medical and electronic field, the present paper seeks the practical implementation of an efficient, low cost, low-power IoT medical system, yet with a greater memory autonomy. In this context, our main contribution is the implementation of a solution for ECG monitoring based on IoT techniques. This paper presents a qualitative research in the field of healthcare IoT and embedded applications meant to provide an innovative and flexible system meeting the stringent requirements of this area. Without compromising the performance intake and the low power consumption, the designers offer flexible options for connectivity and response time.

  10. Applicability of a bioelectronic cardiac monitoring system for the detection of biological effects of pollution in bioindicator species in the Gulf of Finland

    Science.gov (United States)

    Kholodkevich, Sergey V.; Kuznetsova, Tatiana V.; Sharov, Andrey N.; Kurakin, Anton S.; Lips, Urmas; Kolesova, Natalia; Lehtonen, Kari K.

    2017-07-01

    Field testing of an innovative technology based on a bioelectronic cardiac monitoring system was carried out in the Gulf of Finland (Baltic Sea). The study shows that the bioelectronic system is suitable for the selected bivalve mollusks Mytilus trossulus, Macoma balthica and Anodonta anatina. Specimens taken from reference sites demonstrated a heart rate recovery time of < 60 min after testing with changed salinity load, while those collected from sites characterized by high anthropogenic pressure demonstrated a prolonged recovery time of up to 110-360 min. These results make possible a discrimination of the study sites based on the assessment of physiological adaptive capacities of inhabiting species. In addition, the approach of measuring heart rate characteristics in M. balthica transplanted in cages to specific target areas was successfully used to evaluate the decline in the adaptive potential of mollusks exposed at polluted sites. Application of the novel system is a useful tool for the biomonitoring of freshwater and brackish water areas. Development of methodological basis for the testing of adaptive capacities (health) of key aquatic organisms provides new knowledge of biological effects of anthropogenic chemical stress in aquatic organisms.

  11. Economic analysis of remote monitoring of cardiac implantable electronic devices: Results of the Health Economics Evaluation Registry for Remote Follow-up (TARIFF) study.

    Science.gov (United States)

    Ricci, Renato Pietro; Vicentini, Alfredo; D'Onofrio, Antonio; Sagone, Antonio; Rovaris, Giovanni; Padeletti, Luigi; Morichelli, Loredana; Fusco, Antonio; De Vivo, Stefano; Lombardi, Leonida; Denaro, Alessandra; Pollastrelli, Annalisa; Colangelo, Irene; Santini, Massimo

    2017-01-01

    Remote monitoring (RM) of cardiac implantable electronic devices has been demonstrated to improve outpatient clinic workflow and patient management. However, few data are available on the socioeconomic impact of RM. The aim of this study was to assess the costs and benefits of RM compared with standard care (SC). We used 12-month patient data from the Health Economics Evaluation Registry for Remote Follow-up (TARIFF) study (N = 209; RM: n = 102 (48.81%); SC: n = 107 (51.19%)). Cost comparison was made from 2 perspectives: the health care system (HCS) and patients. The use of health care resources was defined on the basis of hospital clinical folders. Out-of-pocket expenses were reported directly by patients. HCS perspective: The overall mean annual cost per patient in the SC group (€1044.89 ± €1990.47) was significantly higher than in the RM group (€482.87 ± €2488.10) (P < .0001), with a reduction of 53.87% being achieved in the RM group. The primary driver of cost reduction was the cost of cardiovascular hospitalizations (SC: €`886.67 ± €1979.13 vs RM: €432.34 ± €2488.10; P = .0030). Patient and caregiver perspective: The annual cost incurred by patients was significantly higher in the SC group than in the RM group (SC: €169.49 ± €189.50 vs RM: €56.87 ± €80.22; P < .0001). Patients' quality-adjusted life-years were not significantly different between the groups. Provider perspective: The total number of inhospital device follow-up visits was reduced by 58.78% in the RM group. RM of patients with cardiac implantable electronic devices (CIEDs) is cost saving from the perspectives of the HCS, patients, and caregivers. Introducing appropriate reimbursements will make RM sustainable even for the provider, i.e. the hospitals which provide the service and encourage widespread adoption of RM. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  12. Oil output's changing fortunes

    International Nuclear Information System (INIS)

    Eldridge, D.

    1994-01-01

    The Petroleum Economist, previously the Petroleum Press Service, has been making annual surveys of output levels of petroleum in all the oil-producing countries since its founding in 1934. This article documents trends and changes in the major oil-producing countries output from 1934 until the present. This analysis is linked with the political and historical events accompanying these changes, notably the growth of Middle Eastern oil production, the North Sea finds and most recently, Iraq's invasion of Kuwait in 1990. (UK)

  13. Technology-Enabled Remote Monitoring and Self-Management - Vision for Patient Empowerment Following Cardiac and Vascular Surgery: User Testing and Randomized Controlled Trial Protocol.

    Science.gov (United States)

    McGillion, Michael; Yost, Jennifer; Turner, Andrew; Bender, Duane; Scott, Ted; Carroll, Sandra; Ritvo, Paul; Peter, Elizabeth; Lamy, Andre; Furze, Gill; Krull, Kirsten; Dunlop, Valerie; Good, Amber; Dvirnik, Nazari; Bedini, Debbie; Naus, Frank; Pettit, Shirley; Henry, Shaunattonie; Probst, Christine; Mills, Joseph; Gossage, Elaine; Travale, Irene; Duquette, Janine; Taberner, Christy; Bhavnani, Sanjeev; Khan, James S; Cowan, David; Romeril, Eric; Lee, John; Colella, Tracey; Choinière, Manon; Busse, Jason; Katz, Joel; Victor, J Charles; Hoch, Jeffrey; Isaranuwatchai, Wanrudee; Kaasalainen, Sharon; Ladak, Salima; O'Keefe-McCarthy, Sheila; Parry, Monica; Sessler, Daniel I; Stacey, Michael; Stevens, Bonnie; Stremler, Robyn; Thabane, Lehana; Watt-Watson, Judy; Whitlock, Richard; MacDermid, Joy C; Leegaard, Marit; McKelvie, Robert; Hillmer, Michael; Cooper, Lynn; Arthur, Gavin; Sider, Krista; Oliver, Susan; Boyajian, Karen; Farrow, Mark; Lawton, Chris; Gamble, Darryl; Walsh, Jake; Field, Mark; LeFort, Sandra; Clyne, Wendy; Ricupero, Maria; Poole, Laurie; Russell-Wood, Karsten; Weber, Michael; McNeil, Jolene; Alpert, Robyn; Sharpe, Sarah; Bhella, Sue; Mohajer, David; Ponnambalam, Sem; Lakhani, Naeem; Khan, Rabia; Liu, Peter; Devereaux, P J

    2016-08-01

    Tens of thousands of cardiac and vascular surgeries (CaVS) are performed on seniors in Canada and the United Kingdom each year to improve survival, relieve disease symptoms, and improve health-related quality of life (HRQL). However, chronic postsurgical pain (CPSP), undetected or delayed detection of hemodynamic compromise, complications, and related poor functional status are major problems for substantial numbers of patients during the recovery process. To tackle this problem, we aim to refine and test the effectiveness of an eHealth-enabled service delivery intervention, TecHnology-Enabled remote monitoring and Self-MAnagemenT-VIsion for patient EmpoWerment following Cardiac and VasculaR surgery (THE SMArTVIEW, CoVeRed), which combines remote monitoring, education, and self-management training to optimize recovery outcomes and experience of seniors undergoing CaVS in Canada and the United Kingdom. Our objectives are to (1) refine SMArTVIEW via high-fidelity user testing and (2) examine the effectiveness of SMArTVIEW via a randomized controlled trial (RCT). CaVS patients and clinicians will engage in two cycles of focus groups and usability testing at each site; feedback will be elicited about expectations and experience of SMArTVIEW, in context. The data will be used to refine the SMArTVIEW eHealth delivery program. Upon transfer to the surgical ward (ie, post-intensive care unit [ICU]), 256 CaVS patients will be reassessed postoperatively and randomly allocated via an interactive Web randomization system to the intervention group or usual care. The SMArTVIEW intervention will run from surgical ward day 2 until 8 weeks following surgery. Outcome assessments will occur on postoperative day 30; at week 8; and at 3, 6, 9, and 12 months. The primary outcome is worst postop pain intensity upon movement in the previous 24 hours (Brief Pain Inventory-Short Form), averaged across the previous 14 days. Secondary outcomes include a composite of postoperative

  14. Complexity analysis of experimental cardiac arrhythmia

    OpenAIRE

    Xu, Binbin; Binczak, Stéphane; Jacquir, Sabir; Pont, Oriol; Yahia, Hussein

    2014-01-01

    International audience; To study the cardiac arrhythmia, an in vitro experimental model and Multielectrodes Array (MEA) are used. This platform serves as an intermediary of the electrical activities of cardiac cells and the signal processing / dynamics analysis. Through it the extracellular potential of cardiac cells is acquired, allowing a real-time monitoring / analyzing. Since MEA has 60 electrodes / channels dispatched in a rectangular region, it allows real-time monitoring and signal acq...

  15. [Diagnosing silent cardiac dysautonomia via ambulatory blood pressure monitoring: early diagnosis shown by the lack of heart rate circadian rhythm in type 1 diabetes mellitus].

    Science.gov (United States)

    Cugini, P; Amato, S; Tarquini, G; Mercuri, S; Turinese, I; Tego, A; Rossetti, M; Panetti, D; Filardi, T; Curione, M; Morano, S

    2010-01-01

    Diabetes mellitus (DM) can be complicated by an involvement of Neurovegetative System (NVS), conventionally and non-invasively diagnosed by the means of Ewing's test and Heart Rate Variability (HRV) analysis. It is well known that the NVS is physiologically responsible, via biological clocks, for the regulation of Circadian Rhythms (CR) characterizing the majority of biological functions. Therefore, this study is aimed at investigating the CR of Heart Rate (HR) and Blood Pressure (BP) in DM, postulating that the diagnosis of Silent Cardiac Dysautonomia (SCD) could be facilitated by detecting anomalous rhythmometric changes, including the worse one, i.e., the lose of a CR. The study has been performed on 30 clinically healthy subjects (CHS), 10 patients with DM1 and 30 patients with DM2, who underwent an ambulatory BP monitoring (ABPM) collecting data equidistantly every 30 minutes, under standardized conditions of lifestyle. The group specific monitored values of systolic (S), diastolic (D) BP, as well as HR have been analyzed via: 1. a conventional analysis of their intradiem variability; 2. a chronobiometric analysis (Cosinor method) of their CR. The conventional analysis disclosed that in CHS, DM1 and DM2, both the HR and BP show an intradiem variability that is significant (p less than 0.001). The chronobiological analysis showed that in CHS and DM2, both the HR and BP show a significant CR (p less than 0.001), viceversa in DM1 HR is characterized by a non significant CR (p=0.124), notwithstanding that the SBP and DBP maintain a significant CR (p less than 0.001). The disappearance of HR CR in DM1 reveals the involvement of neurovegetative biological clock that selectively controls the HR CR, as it is demonstrated by the pathophysiological finding of an internal desynchronization between the HR and BP CR. The selective lose of HR CR in DM1 leads to conclude that the ABPM, along with its Cosinor analysis, might be a practical, repeatable, low cost, low risk

  16. Toll-Like Receptor 9 Promotes Cardiac Inflammation and Heart Failure during Polymicrobial Sepsis

    Directory of Open Access Journals (Sweden)

    Ralph Lohner

    2013-01-01

    Full Text Available Background. Aim was to elucidate the role of toll-like receptor 9 (TLR9 in cardiac inflammation and septic heart failure in a murine model of polymicrobial sepsis. Methods. Sepsis was induced via colon ascendens stent peritonitis (CASP in C57BL/6 wild-type (WT and TLR9-deficient (TLR9-D mice. Bacterial load in the peritoneal cavity and cardiac expression of inflammatory mediators were determined at 6, 12, 18, 24, and 36 h. Eighteen hours after CASP cardiac function was monitored in vivo. Sarcomere length of isolated cardiomyocytes was measured at 0.5 to 10 Hz after incubation with heat-inactivated bacteria. Results. CASP led to continuous release of bacteria into the peritoneal cavity, an increase of cytokines, and differential regulation of receptors of innate immunity in the heart. Eighteen hours after CASP WT mice developed septic heart failure characterised by reduction of end-systolic pressure, stroke volume, cardiac output, and parameters of contractility. This coincided with reduced cardiomyocyte sarcomere shortening. TLR9 deficiency resulted in significant reduction of cardiac inflammation and a sustained heart function. This was consistent with reduced mortality in TLR9-D compared to WT mice. Conclusions. In polymicrobial sepsis TLR9 signalling is pivotal to cardiac inflammation and septic heart failure.

  17. Cardiac acceleration at the onset of exercise: a potential parameter for monitoring progress during physical exercise training in sports and rehabilitation

    NARCIS (Netherlands)

    Hettinga, F.J.; Monden, P.G.; Van Meeteren, N.L.U.; Daanen, H.A.M.

    2014-01-01

    There is a need for easy-to-use methods to assess training progress in sports and rehabilitation research. The present review investigated whether cardiac acceleration at the onset of physical exercise (HR

  18. Criticality alarm output device

    International Nuclear Information System (INIS)

    Sasaki, Takashi.

    1994-01-01

    The present invention concerns a device used for detection of a critical accident in facilities which handle nuclear fuels, which especially removes the influences of external noises. Namely, a radiation detector outputs logic signals based on trip signals generated by the change of the radiation dose due to occurrence of a critical accident. The logic signal is sent to a logic judging circuit by way of a transmission path present individually in each of radiation detectors. The radiation detector comprises a first inverting means which sends a signal having a level inverted to a logic signal level to the logic judging circuit passing through a transmission path. The logic judging circuit comprises a second reversing means for inverting the level of the signal from the first inverting means and a signal judging means which outputs a conditional signal when the output sent from the second inverting means and the logic signal sent from the radiation detector arrive simultaneously. With such a constitution, influences of external noises intruded to the transmission path can be removed. (I.S.)

  19. The use of pneumoperitoneum during laparoscopic surgery as a model to study pathophysiologic phenomena: the correlation of cardiac functionality with computerized acoustic indices--preliminary data.

    Science.gov (United States)

    Bickel, Amitai; Eitan, Arieh; Melnik, Dimitry; Weiss, Atalia; Gavrieli, Noam; Kniaz, David; Intrator, Nathan

    2012-05-01

    Induction of pneumoperitoneum during laparoscopic surgery leads to diverse cardiovascular changes that can be used as a model to study pathophysiologic phenomena. Application of novel signal processing and figure extraction enabled searching for correlation between various signals and pathophysiologic setting. Our aim was to quantitatively correlate cardiac functionality (as expressed by cardiac output) with the spectral energy of the first heart sound (S1) obtained from the phonocardiogram, during laparoscopic surgery. Patients who were scheduled for elective laparoscopic operations were enrolled in the study. Cardiac output was maximally changed during anesthesia and abdominal insufflation and was obtained from the arterial pressure wave (FloTrac™ sensor and Vigileo™ monitor [Edwards Lifesciences Ltd.]). Heart signals were recorded during surgery from each subject by a computerized digital data acquisition system. The automatic analysis of the heart sounds included segmentation that was based on the energy envelope of the heart sounds together with analysis of the electrocardiogram signal. We analyzed the morphology of the sounds using hierarchial cluster analysis to remove those sounds that were not reliably recorded. The magnitude of the amplitude of heart sounds was obtained by using the Hilbert transform for each heartbeat. Statistical analysis was based on linear regression. Following exclusion of 3 patients (mainly because of technical reasons), we were left with 7 patients who demonstrated statistically significant positive correlation between cardiac index and the amplitude of S1 (regression coefficient between 0.4 and 0.9, Pfunctionality, through sophisticated computerized analysis, using the pneumoperitoneum model for changing the cardiac output.

  20. Cardiac asystole in partial seizures.

    Science.gov (United States)

    Scott, C A; Fish, D R

    2000-06-01

    Literature review shows many anecdotal case reports of cardiac asystole in ictal recordings of partial seizures. We have reviewed our data from the last five years, of patients who are being assessed for epilepsy surgery and found 2 out of more than 1,500 complex partial seizures, recorded in 589 consecutive patients, showing a significant period of asystole (13 and 15 seconds). Our previous studies of cardiac and respiratory parameters during partial seizures showed that a central apnoea occurred in 39%. It is probable that sudden death during seizures is due to the interaction of both cardiac and respiratory irregularities. Although rare (occurrence cardiac asystole occurring in an epilepsy monitoring unit highlights the need for resuscitation equipment to be readily available and for trained nursing staff. Furthermore, it is important to recognize that the semiology of seizures may be affected by the consequences of secondary cardiac asystole.

  1. Effects of Exercise Training on Haematology and Maximal Cardiac Output

    DEFF Research Database (Denmark)

    Bonne, Thomas Christian

    -score and the abnormal blood profile score (ABPS) were generated using the official ABP software. After altitude training, six swimmers exceeded the 99% ABP thresholds: Two swimmers exceeded the OFF-score thresholds at day 7; One swimmer exceeded the OFF-score threshold at day 28; One swimmer exceeded the threshold...... = 0.051) and time to complete 3000 m tended (P = 0.09) to increase in LHTH but not after sea level training. In study III haematological parameters were determined weekly three times before and four times after classical altitude and sea level training and ABP thresholds for [Hb], %ret, OFF...... for %ret at day 14; One swimmer surpassed the ABPS threshold at day 7 and one swimmer exceeded the ABPS threshold 28 days after altitude training. No values exceeded the individual thresholds in the control group. In conclusion, this thesis demonstrated that BV is a main determinant of the exercise induced...

  2. Does bronchial thermodilution allow estimation of cardiac output?

    NARCIS (Netherlands)

    Loer, SA; Wietasch, JKG; Scheeren, TWL

    Objective: Transcapillary heat transfer after injections of cold saline into the right atrium generates bronchial thermodilution curves resembling those observed in the aorta. Under the assumption that no indicator is lost or gained within the pulmonary capillary bed and changes in blood temperature

  3. Effects of Exercise Training on Haematology and Maximal Cardiac Output

    DEFF Research Database (Denmark)

    Bonne, Thomas Christian

    to the heart ultra structure possibly also play a role for improving Qmax. Other mechanisms that can improve exercise capacity include hypoxia. It is universally accepted that hypoxia is a main stimulant of erythropoiesis and altitude training is considered a possibility to increase red blood cell volume...... and hence exercise performance in elite athletes. However, the efficacy of altitude training for sea level performance is still debated and the literature is divergent on this matter. Even if the haematological changes following altitude training may be inadequate to substantially improve performance...... altitude training camp on Hbmass and VO2max were studied in 10 Olympic swimmers. Ten swimmers of comparable characteristics were chosen for a sea level control group. Both the altitude and sea level group completed a similar training intervention at either altitude or sea level. Hbmass significantly...

  4. Body monitoring and imaging apparatus and method

    Science.gov (United States)

    McEwan, T.E.

    1998-06-16

    A non-acoustic pulse-echo radar monitor is employed in the repetitive mode, whereby a large number of reflected pulses are averaged to produce a voltage that modulates an audio oscillator to produce a tone that corresponds to the heart motion. The antenna used in this monitor generally comprises two flat copper foils, thus permitting the antenna to be housed in a substantially flat housing. The monitor converts the detected voltage to an audible signal with both amplitude modulation and Doppler effect. It further uses a dual time constant to reduce the effect of gross sensor-to-surface movement. The monitor detects the movement of one or more internal body parts, such as the heart, lungs, arteries, and vocal chords, and includes a pulse generator for simultaneously inputting a sequence of pulses to a transmit path and a grating path. The pulses transmitted along the transmit path drive Oh impulse, generator and provide corresponding transmit pulses that are applied to a transmit antenna. The gating path includes a range delay generator which generates timed gating pulses. The timed gating pulses cause the receive path to selectively conduct pulses reflected from the body parts and received by a receive antenna. The monitor output potential can be separated into a cardiac output indicative of the physical movement of the heart, and a pulmonary output indicative of the physical movement of the lung. The impulse generator in the transmit path can be replaced with a pulsed RF generator. 13 figs.

  5. A study of potential output and output gap in the Czech Republic

    Directory of Open Access Journals (Sweden)

    Václav Adamec

    2012-01-01

    Full Text Available Analysis of economic cycle is of enormous importance for monitoring economic output and explaining price and wage inflation. It provides essential information for shaping economic and monetary policy of central authorities. Several methods are currently available to estimate potential output and output gap. In the current study, methods of Hodrick-Prescott filter and Cobb-Douglas production function were implemented to estimate potential output, which cannot be empirically observed. For the purpose of comparing the above methods, quarterly and annual time series of real GDP, labour and gross fixed capital starting in 1996 were used for estimation of the output gap. Relative contributions of labour, fixed capital formation and technology improvement factor towards growth of potential output were quantified for the studied series. The Cobb-Douglas production function appears to be superior to Hodrick-Prescott filter in providing quality estimates of potential output. Hodrick-Prescott filter allows estimation of potential output; nevertheless, it fails to identify components of cyclic behaviour of economic activity. Cobb-Douglas production function describes level of potential product assuming average utilization of production factors. A detailed analysis of components of economic growth in the observed period is provided.

  6. Cardiac Rehabilitation

    Science.gov (United States)

    ... may also do muscle-strengthening exercises, such as lifting weights or other resistance training exercises, two or three ... health concerns. Education about nutrition, lifestyle and healthy weight ... the most benefits from cardiac rehabilitation, make sure your exercise and ...

  7. Cardiac MRI

    Science.gov (United States)

    ... such as coronary heart disease, heart valve problems, pericarditis, cardiac tumors, or damage from a heart attack. ... Palpitations Heart Valve Disease Implantable Cardioverter Defibrillators Pacemakers Pericarditis Stress Testing RELATED NEWS April 26, 2013 | News ...

  8. Cardiac Angiosarcoma

    Directory of Open Access Journals (Sweden)

    Monique Esteves Cardoso

    2011-01-01

    Full Text Available Despite cardiac metastases are found in about 20% of cancer deaths, the presence of primary cardiac tumors is rare. Most primary tumors are benign, and malignant tumors comprise about 15%. We report a 21-year-old man with fever, dyspnea, and hemoptysis that was diagnosed with angiosarcoma of the right atrium and pulmonary metastasis. Patient was submitted to surgical tumor resection without adjuvant therapy and died four months after diagnosis.

  9. Cardiac Angiosarcoma

    OpenAIRE

    Cardoso, Monique Esteves; Canale, Leonardo Secchin; Ramos, Rosana Grandelle; Salvador Junior, Edson da Silva; Lachtermacher, Stephan

    2011-01-01

    Despite cardiac metastases are found in about 20% of cancer deaths, the presence of primary cardiac tumors is rare. Most primary tumors are benign, and malignant tumors comprise about 15%. We report a 21-year-old man with fever, dyspnea, and hemoptysis that was diagnosed with angiosarcoma of the right atrium and pulmonary metastasis. Patient was submitted to surgical tumor resection without adjuvant therapy and died four months after diagnosis.

  10. Cardiac Angiosarcoma

    Science.gov (United States)

    Cardoso, Monique Esteves; Canale, Leonardo Secchin; Ramos, Rosana Grandelle; Salvador Junior, Edson da Silva; Lachtermacher, Stephan

    2011-01-01

    Despite cardiac metastases are found in about 20% of cancer deaths, the presence of primary cardiac tumors is rare. Most primary tumors are benign, and malignant tumors comprise about 15%. We report a 21-year-old man with fever, dyspnea, and hemoptysis that was diagnosed with angiosarcoma of the right atrium and pulmonary metastasis. Patient was submitted to surgical tumor resection without adjuvant therapy and died four months after diagnosis. PMID:24826214

  11. Relationship between cardiac function and resting cerebral blood flow

    DEFF Research Database (Denmark)

    Henriksen, Otto M; Jensen, Lars T; Krabbe, Katja

    2014-01-01

    Although both impaired cardiac function and reduced cerebral blood flow are associated with ageing, current knowledge of the influence of cardiac function on resting cerebral blood flow (CBF) is limited. The aim of this study was to investigate the potential effects of cardiac function on CBF. CBF......) and 2.4 l min(-1) m(-2), respectively, in females. No effects of cardiac output or cardiac index on CBF or structural signs of brain ageing were observed. However, fractional brain flow defined as the ratio of total brain flow to cardiac output was inversely correlated with cardiac index (r(2) = 0.22, P...... = 0.008) and furthermore lower in males than in females (8.6% versus 12.5%, P = 0.003). Fractional brain flow was also inversely correlated with cerebral white matter lesion grade, although this effect was not significant when adjusted for age. Frequency analysis of heart rate variability showed...

  12. Hemodynamic monitoring during CPR.

    Science.gov (United States)

    Ornato, J P

    1993-02-01

    Real-time hemodynamic monitoring provides useful information that can be used to assess and optimize mechanical and pharmacological interventions during CPR. The standard algorithms should always be the initial approach to resuscitation, because they offer a rapid, logical, coordinated series of treatments with proven success. Pressure and flow measurements during conventional, closed-chest CPR in humans indicate that the technique typically produces a hemodynamic state resembling profound cardiogenic shock, with a low systemic arterial pressure, markedly reduced cardiac output, and high intravascular filling pressures. End-tidal carbon dioxide monitoring provides useful, noninvasive information during clinical resuscitation. A low end-tidal carbon dioxide value during resuscitation should alert the rescuers that something is wrong with ventilation, perfusion, and/or carbon dioxide production and should prompt a search for correctable causes. If one or more hemodynamic parameters are being monitored at the time the patient develops cardiac arrest (eg, an intensive care unit patient who has an arterial line and a pulmonary artery catheter in place), it is appropriate for the resuscitation team to pay attention to the data that are generated during the resuscitation, particularly if the initial algorithm approach is not successful. For patients who are not being monitored at the time of their arrest, end-tidal carbon dioxide measurements provide noninvasive, semiquantitative information that can help the team detect and troubleshoot problems during resuscitation. Further research and better, more affordable technologies are needed to provide in- and out-of-hospital resuscitation teams feedback on the hemodynamic effectiveness of their resuscitative efforts.

  13. Site compare scripts and output

    Data.gov (United States)

    U.S. Environmental Protection Agency — Monthly site compare scripts and output used to generate the model/ob plots and statistics in the manuscript. The AQS hourly site compare output files are not...

  14. Endothelial Function as a Possible Significant Determinant of Cardiac Function during Exercise in Patients with Structural Heart Disease

    Directory of Open Access Journals (Sweden)

    Bonpei Takase

    2009-01-01

    Full Text Available This study was investigated the role that endothelial function and systemic vascular resistance (SVR play in determining cardiac function reserve during exercise by a new ambulatory radionuclide monitoring system (VEST in patients with heart disease. The study population consisted of 32 patients. The patients had cardiopulmonary stress testing using the treadmill Ramp protocol and the VEST. The anaerobic threshold (AT was autodetermined using the V-slope method. The SVR was calculated by determining the mean blood pressure/cardiac output. Flow-mediated vasodilation (FMD was measured in the brachial artery to evaluate endotheilial function. FMD and the percent change f'rom rest to AT in SVR correlated with those from rest to AT in ejection fraction and peak ejection ratio by VEST, respectively. Our findings suggest that FMD in the brachial artery and the SVR determined by VEST in patients with heart disease can possibly reflect cardiac function reserve during aerobic exercise.

  15. Metoclopramide-induced cardiac arrest

    Directory of Open Access Journals (Sweden)

    Martha M. Rumore

    2011-11-01

    Full Text Available The authors report a case of cardiac arrest in a patient receiving intravenous (IV metoclopramide and review the pertinent literature. A 62-year-old morbidly obese female admitted for a gastric sleeve procedure, developed cardiac arrest within one minute of receiving metoclopramide 10 mg via slow intravenous (IV injection. Bradycardia at 4 beats/min immediately appeared, progressing rapidly to asystole. Chest compressions restored vital function. Electrocardiogram (ECG revealed ST depression indicative of myocardial injury. Following intubation, the patient was transferred to the intensive care unit. Various cardiac dysrrhythmias including supraventricular tachycardia (SVT associated with hypertension and atrial fibrillation occurred. Following IV esmolol and metoprolol, the patient reverted to normal sinus rhythm. Repeat ECGs revealed ST depression resolution without pre-admission changes. Metoclopramide is a non-specific dopamine receptor antagonist. Seven cases of cardiac arrest and one of sinus arrest with metoclopramide were found in the literature. The metoclopramide prescribing information does not list precautions or adverse drug reactions (ADRs related to cardiac arrest. The reaction is not dose related but may relate to the IV administration route. Coronary artery disease was the sole risk factor identified. According to Naranjo, the association was possible. Other reports of cardiac arrest, severe bradycardia, and SVT were reviewed. In one case, five separate IV doses of 10 mg metoclopramide were immediately followed by asystole repeatedly. The mechanism(s underlying metoclopramide’s cardiac arrest-inducing effects is unknown. Structural similarities to procainamide may play a role. In view of eight previous cases of cardiac arrest from metoclopramide having been reported, further elucidation of this ADR and patient monitoring is needed. Our report should alert clinicians to monitor patients and remain diligent in surveillance and

  16. Teacher Talk and Language Output

    OpenAIRE

    Haiyan Wang

    2014-01-01

    As an important input and teaching media in foreign language teaching classes, teacher talk (TT) has a great effect on language output. This paper explores the problems related to teacher talk (TT) and language output in practical ELT (English Language Teaching) classroom and presents some suggestions for solving the problems which affect learner' effective language output.

  17. Milrinone ameliorates cardiac mechanical dysfunction after hypothermia in an intact rat model.

    Science.gov (United States)

    Dietrichs, Erik Sveberg; Kondratiev, Timofei; Tveita, Torkjel

    2014-12-01

    Rewarming from hypothermia is often complicated by cardiac dysfunction, characterized by substantial reduction in stroke volume. Previously we have reported that inotropic agents, working via cardiac β-receptor agonism may exert serious side effects when applied to treat cardiac contractile dysfunction during rewarming. In this study we tested whether Milrinone, a phosphodiesterase III inhibitor, is able to ameliorate such dysfunction when given during rewarming. A rat model designed for circulatory studies during experimental hypothermia with cooling to a core temperature of 15°C, stable hypothermia at this temperature for 3h and subsequent rewarming was used, with a total of 3 groups: (1) a normothermic group receiving Milrinone, (2) a hypothermic group receiving Milrinone the last hour of hypothermia and during rewarming, and (3) a hypothermic saline control group. Hemodynamic function was monitored using a conductance catheter introduced to the left ventricle. After rewarming from 15°C, stroke volume and cardiac output returned to within baseline values in Milrinone treated animals, while these variables were significantly reduced in saline controls. Milrinone ameliorated cardiac dysfunction during rewarming from 15°C. The present results suggest that at low core temperatures and during rewarming from such temperatures, pharmacologic efforts to support cardiovascular function is better achieved by substances preventing cyclic AMP breakdown rather than increasing its formation via β-receptor stimulation. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Systemic Amyloidosis and Cardiac Autonomic Neuropathy Associated with Waldenstrom’s Macroglobulinemia

    Directory of Open Access Journals (Sweden)

    Aasems Jacob

    2017-01-01

    Full Text Available A 73-year-old male with long-standing Waldenstrom’s macroglobulinemia complicated with systemic amyloidosis presented with a witnessed syncopal episode. He had complaints of orthostatic dizziness and palpitations for few months. Orthostatic hypotension and peripheral neuropathy were demonstrated on physical examination. EKG, 24-hour Holter monitoring, and 2D echocardiogram were unremarkable. MRI of the brain ruled out stroke. Patients with amyloidosis can develop cardiovascular disease through amyloid cardiomyopathy, small vessel disease, conduction defects, pericardial effusion, or autonomic denervation. After ruling out other life-threatening causes, Ewing’s battery of tests was done to rule out cardiac autonomic neuropathy. Two heart rate tests and one blood pressure test were abnormal which indicated severe cardiac autonomic neuropathy. Cardiac autonomic neuropathy can mask symptoms of acute coronary syndrome and hence early diagnosis using the simple bedside maneuver is beneficial. The test is also important for prognostication. Absence of augmentation of cardiac output from inadequate autonomic stimulation will lead to postural hypotension, exercise intolerance, and tachycardia. There may be no change in heart rate with Valsalva or deep breathing both of which increase parasympathetic tone. As the condition progresses, it may result in cardiac denervation which can result in silent myocardial infarction, syncope, and sudden death.

  19. Cardiac echinococcosis

    Directory of Open Access Journals (Sweden)

    Ivanović-Krstić Branislava A.

    2002-01-01

    Full Text Available Cardiac hydatid disease is rare. We report on an uncommon hydatid cyst localized in the right ventricular wall, right atrial wall tricuspid valve left atrium and pericard. A 33-year-old woman was treated for cough, fever and chest pain. Cardiac echocardiograpic examination revealed a round tumor (5.8 x 4 cm in the right ventricular free wall and two smaller cysts behind that tumor. There were cysts in right atrial wall and tricuspidal valve as well. Serologic tests for hydatidosis were positive. Computed tomography finding was consistent with diagnosis of hydatid cyst in lungs and right hylar part. Surgical treatment was rejected due to great risk of cardiac perforation. Medical treatment with albendazole was unsuccessful and the patient died due to systemic hydatid involvement of the lungs, liver and central nervous system.

  20. [Cardiac amyloidosis].

    Science.gov (United States)

    Boussabah, Elhem; Zakhama, Lilia; Ksontini, Iméne; Ibn Elhadj, Zied; Boukhris, Besma; Naffeti, Sana; Thameur, Moez; Ben Youssef, Soraya

    2008-09-01

    PREREQUIS: Amyloidosis is a rare infiltrative disease characterized by multiple clinical features. Various organs are involved and the cardiovascular system is a common target of amyloidosis. Cardiac involvement may occur with or without clinical manifestations and is considered as a major prognostic factor. To analyze the clinical features of cardiac involvement, to review actual knowledgement concerning echocardiographic diagnostic and to evaluate recent advances in treatment of the disease. An electronic search of the relevant literature was carried out using Medline and Pubmed. Keys words used for the final search were amyloidosis, cardiopathy and echocardiography. We considered for analysis reviews, studies and articles between 1990 and 2007. Amyloidosis represents 5 to 10% of non ischemic cardiomyoparhies. Cardiac involvement is the first cause of restrictive cardiomyopathy witch must be evoked in front of every inexplained cardiopathy after the age of forty. The amyloid nature of cardiopathy is suggered if some manifestations were associated as a peripheric neuropathy, a carpal tunnel sydrome and proteinuria > 3g/day. Echocardiography shows dilated atria, a granular sparkling appearance of myocardium, diastolic dysfunction and thickened left ventricle contrasting with a low electric voltage. The proof of amyloidosis is brought by an extra-cardiac biopsy, the indications of endomyocardial biopsy are very limited. The identification of the amyloid nature of cardiopathy has an direct therapeutic implication: it indicates the use of digitalis, calcium channel blockers and beta-blockers. Today the treatment of amyloidosis remains very unsatisfactory especially in the cardiac involvement. An early diagnosis before the cardiac damage may facilitate therapy and improve prognosis.

  1. Risk factors for low cardiac output syndrome after coronary artery bypass grafting surgery Fatores de risco para síndrome de baixo débito cardíaco após cirurgia de revascularização miocárdica

    Directory of Open Access Journals (Sweden)

    Michel Pompeu Barros de Oliveira Sá

    2012-06-01

    Full Text Available OBJECTIVES: Low cardiac output syndrome (LCOS is a serious complication after cardiac surgery and is associated with significant morbidity and mortality. The aim of this study is to identify risk factors for LCOS in patients undergoing coronary artery bypass grafting (CABG in the Division of Cardiovascular Surgery of Pronto Socorro Cardiológico de Pernambuco - PROCAPE (Recife, PE, Brazil. METHODS: A historical prospective study comprising 605 consecutive patients operated between May 2007 and December 2010. We evaluated 12 preoperative and 7 intraoperative variables. We applied univariate and multivariate logistic regression analysis. RESULTS: The incidence of LCOS was 14.7% (n = 89, with a lethality rate of 52.8% (n = 47. In multivariate analysis by logistic regression, four variables remained as independent risk factors: age > 60 years (OR 2.00, 95% CI 1.20 to 6.14, P = 0.009, on-pump CABG (OR 2.16, 95% CI 1.40 to 7.08, P = 0.006, emergency surgery (OR 4.71, 95% CI 1.34 to 26.55, P = 0.028, incomplete revascularization (OR 2.62, 95% CI 1.32 to 5.86, P = 0.003, and ejection fraction 60 years of off-pump CABG, emergency surgery, incomplete CABG and ejection fraction OBJETIVOS: A síndrome de baixo débito cardíaco (SBDC é uma complicação grave após cirurgias cardíacas, estando associada à significativa morbidade e mortalidade. O objetivo deste estudo é identificar fatores de risco para SBDC em pacientes submetidos à cirurgia de revascularização miocárdica (CRM, na Divisão de Cirurgia Cardiovascular do Pronto Socorro Cardiológico de Pernambuco - PROCAPE (Recife, PE, Brasil. MÉTODOS: Estudo prospectivo histórico compreendendo 605 pacientes consecutivos operados entre maio de 2007 e dezembro de 2010. Avaliaram-se 12 variáveis pré-operatórias e sete variáveis intraoperatórias. Aplicaram-se análises univariada e multivariada por regressão logística. RESULTADOS: A incidência de SBDC foi de 14,7% (n = 89, com taxa de

  2. Nursing care to patients with PiCCO monitoring

    Directory of Open Access Journals (Sweden)

    Ramona Rodríguez Flores

    2009-03-01

    Full Text Available The monitoring of physiological parameters turns out to be indispensable to obtain a treatment directed therapeutic in critical patients.In the Units of Intensive care it is in the habit of being frequent to meet complex systems of monitoring homodynamic, since they are the Catheter of Pulmonary Artery (CAP or of Swan-Ganz and the system of monitoring PiCCO (In English, Pulse-Induced Contour Cardiac Output, to measure the Cardiac Output for analysis of the curve of the arterial pulse.These systems are of necessary in patients with great instability homodynamic, septic shock, injury or pulmonary hurt and organic hurt.The lens of this work, it is to announce the system of monitoring PiCCO since it is a relatively new system and allows measuring parameters that do not decide with the catheter Swan-Ganz, besides other advantages. Also we have elaborated a plan of taken care of standard Nursing to patients with monitoring PiCCO.For his production we have based on a wide bibliographical review and expert consults professionals, as well as a deep navigation for Internet.

  3. Safety of intravenous insulin aspart compared to regular human insulin in patients undergoing ICU monitoring post cardiac surgery: an Indian experience.

    Science.gov (United States)

    Chawla, Manoj; Malve, Harshad; Shah, Harshvi; Shinde, Shwetal; Bhoraskar, Anil

    2015-01-01

    Poor perioperative glycemic control increases risk of infection, cardiovascular accidents and mortality in patients undergoing surgery. Tight glycemic control by insulin therapy is known to yield better outcomes in such patients. Intravenous (IV) insulin therapy with or without adjunctive subcutaneous insulin therapy is the mainstay of managing hyperglycemia in perioperative period. This observational study assessed the safety of IV Insulin Aspart (IAsp) as compared to Regular Human Insulin (RHI) in patients undergone cardiac surgery at a tertiary care hospital. 203 patients received IV IAsp (n = 103) and RHI (n = 100) respectively. Safety was assessed by frequency and severity of adverse events (AEs) & serious adverse events (SAEs) during hospitalization. IAsp effectively controlled mean blood glucose levels to 159.87 ± 41.41 mg/dl similar to RHI (160.77 ± 44.39 mg/dl). No serious adverse event was reported. The incidence of hypoglycemia was similar in both the groups. The insulin infusion rate, time for which insulin infusion was withheld and mean blood glucose during hypoglycemia was significantly high in RHI group. This study has shown similar safety of IV IAsp as compared to IV RHI in the post cardiac surgery patients. However physicians preferred IAsp as it offers advantage during transition. IV IAsp offers an effective and safe option for managing hyperglycemia in patients in ICU post cardiac procedures.

  4. Cardiac Pacemakers

    International Nuclear Information System (INIS)

    Fiandra, O.; Espasandin, W.; Fiandra, H.

    1984-01-01

    A complete survey of physiological biophysical,clinical and engineering aspects of cardiac facing,including the history and an assessment of possible future developments.Among the topics studied are: pacemakers, energy search, heart stimulating with pacemakers ,mathematical aspects of the electric cardio stimulation chronic, pacemaker implants,proceeding,treatment and control

  5. Cardiac nuclear medicine

    Energy Technology Data Exchange (ETDEWEB)

    Gerson, M.C.

    1987-01-01

    The book begins with a review of the radionuclide methods available for evaluating cardiac perfusion and function. The authors discuss planar and tomographic thallium myocardial imaging, first-pass and equilibrium radionuclide angiography, and imaging with infarct-avid tracers. Several common but more specialized procedures are then reviewed: nonogemetric measurement of left ventricular volume, phase (Fourier) analysis, stroke volume ratio, right ventricular function, and diastolic function. A separate chapter is devoted to drug interventions and in particular the use of radionuclide ventriculography to monitor doxorubicin toxicity and therapy of congestive heart failure. The subsequent chapters provide a comprehensive guide to test selection, accuracy, and results in acute myocardial infarction, in postmyocardial infarction, in chronic coronary artery disease, before and after medical or surgical revascularization, in valvular heart disease, in cardiomyopathies, and in cardiac trauma.

  6. Serial Input Output

    Energy Technology Data Exchange (ETDEWEB)

    Waite, Anthony; /SLAC

    2011-09-07

    Serial Input/Output (SIO) is designed to be a long term storage format of a sophistication somewhere between simple ASCII files and the techniques provided by inter alia Objectivity and Root. The former tend to be low density, information lossy (floating point numbers lose precision) and inflexible. The latter require abstract descriptions of the data with all that that implies in terms of extra complexity. The basic building blocks of SIO are streams, records and blocks. Streams provide the connections between the program and files. The user can define an arbitrary list of streams as required. A given stream must be opened for either reading or writing. SIO does not support read/write streams. If a stream is closed during the execution of a program, it can be reopened in either read or write mode to the same or a different file. Records represent a coherent grouping of data. Records consist of a collection of blocks (see next paragraph). The user can define a variety of records (headers, events, error logs, etc.) and request that any of them be written to any stream. When SIO reads a file, it first decodes the record name and if that record has been defined and unpacking has been requested for it, SIO proceeds to unpack the blocks. Blocks are user provided objects which do the real work of reading/writing the data. The user is responsible for writing the code for these blocks and for identifying these blocks to SIO at run time. To write a collection of blocks, the user must first connect them to a record. The record can then be written to a stream as described above. Note that the same block can be connected to many different records. When SIO reads a record, it scans through the blocks written and calls the corresponding block object (if it has been defined) to decode it. Undefined blocks are skipped. Each of these categories (streams, records and blocks) have some characteristics in common. Every stream, record and block has a name with the condition that each

  7. National Cardiac Device Surveillance Program Database

    Data.gov (United States)

    Department of Veterans Affairs — The National Cardiac Device Surveillance Program Database supports the Eastern Pacemaker Surveillance Center (EPSC) staff in its function of monitoring some 11,000...

  8. Inverter communications using output signal

    Science.gov (United States)

    Chapman, Patrick L.

    2017-02-07

    Technologies for communicating information from an inverter configured for the conversion of direct current (DC) power generated from an alternative source to alternating current (AC) power are disclosed. The technologies include determining information to be transmitted from the inverter over a power line cable connected to the inverter and controlling the operation of an output converter of the inverter as a function of the information to be transmitted to cause the output converter to generate an output waveform having the information modulated thereon.

  9. Unstable resonator with multiple outputs

    Science.gov (United States)

    Konopnicki, M. J.; Smithers, M. E.

    1983-03-01

    Two or more unstable optical resonators can be coupled together by sharing optical elements. The result is then a single compound resonator with multiple outputs. For identical coupled cavities, the transverse structure of the outputs would be identical. In general, there will be misalignments and other aberrations that will vary from cavity to cavity. The cumulative effects of such aberrations are treated using both analytical and numerical approaches. It is shown that the average output of a multioutput resonator is the same as the output of a single uncoupled resonator with aberrations equal to the average of those contained in the multioutput resonator.

  10. Effect of alectinib on cardiac electrophysiology: results from intensive electrocardiogram monitoring from the pivotal phase II NP28761 and NP28673 studies.

    Science.gov (United States)

    Morcos, Peter N; Bogman, Katrijn; Hubeaux, Stanislas; Sturm-Pellanda, Carolina; Ruf, Thorsten; Bordogna, Walter; Golding, Sophie; Zeaiter, Ali; Abt, Markus; Balas, Bogdana

    2017-03-01

    Alectinib, a central nervous system (CNS)-active ALK inhibitor, has demonstrated efficacy and safety in ALK+ non-small-cell lung cancer that has progressed following crizotinib treatment. Other ALK inhibitors have shown concentration-dependent QTc prolongation and treatment-related bradycardia. Therefore, this analysis evaluated alectinib safety in terms of electrophysiologic parameters. Intensive triplicate centrally read electrocardiogram (ECG) and matched pharmacokinetic data were collected across two alectinib single-arm trials. Analysis of QTcF included central tendency analysis [mean changes from baseline with one-sided upper 95% confidence intervals (CIs)], categorical analyses, and relationship between change in QTcF and alectinib plasma concentrations. Alectinib effects on other ECG parameters (heart rate, PR interval and QRS duration) were also evaluated. Alectinib did not cause a clinically relevant change in QTcF. The maximum mean QTcF change from baseline was 5.3 ms observed pre-dose at week 2. The upper one-sided 95% CI was exposure-dependent decrease in mean heart rate of ~11 to 13 beats per minute at week 2. No clinically relevant effects were seen on other ECG parameters. Approximately 5% of patients reported cardiac adverse events of bradycardia or sinus bradycardia; however, these were all grade 1-2. Alectinib does not prolong the QTc interval or cause changes in cardiac function to a clinically relevant extent, with the exception of a decrease in heart rate which was generally asymptomatic.

  11. Effects of exercise rehabilitation on cardiac electrical instability assessed by T-wave alternans during ambulatory electrocardiogram monitoring in coronary artery disease patients without and with diabetes mellitus.

    Science.gov (United States)

    Kenttä, Tuomas; Tulppo, Mikko P; Nearing, Bruce D; Karjalainen, Jaana J; Hautala, Arto J; Kiviniemi, Antti M; Huikuri, Heikki V; Verrier, Richard L

    2014-09-15

    Effects of exercise rehabilitation on electrocardiographic markers of risk for sudden cardiac death have not been adequately studied. We examined effects of controlled exercise training on T-wave alternans (TWA) in 24-hour ambulatory electrocardiogram recordings in patients with stable coronary artery disease (CAD) without and with type 2 diabetes mellitus (DM). Consecutive patients with angiographically confirmed CAD were recruited to join the ARTEMIS (Innovation to Reduce Cardiovascular Complications of Diabetes at the Intersection) study. Exercise (n = 65) and control groups (n = 65) were matched on age, sex, DM, and previous myocardial infarction. Ambulatory electrocardiograms were recorded before and after a 2-year training period. TWA was assessed using time domain-modified moving average method by an investigator blinded to patients' clinical status. Average TWA values decreased in the rehabilitation group but not in control patients (rehabilitation [mean ± SEM]: 52.8 ± 1.7 μV vs 48.7 ± 1.5 μV, p exercise versus 10% (n = 2 of 20) of controls (p = 0.020). In CAD patients, 30% (n = 8 of 27) of positive TWA cases were converted with exercise versus 4% (n = 1 of 28) of controls (p = 0.012). In conclusion, this is the first report of the effectiveness of exercise rehabilitation to reduce TWA, a marker of sudden cardiac death risk, in patients with stable CAD. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Input-output maps are strongly biased towards simple outputs.

    Science.gov (United States)

    Dingle, Kamaludin; Camargo, Chico Q; Louis, Ard A

    2018-02-22

    Many systems in nature can be described using discrete input-output maps. Without knowing details about a map, there may seem to be no a priori reason to expect that a randomly chosen input would be more likely to generate one output over another. Here, by extending fundamental results from algorithmic information theory, we show instead that for many real-world maps, the a priori probability P(x) that randomly sampled inputs generate a particular output x decays exponentially with the approximate Kolmogorov complexity [Formula: see text] of that output. These input-output maps are biased towards simplicity. We derive an upper bound P(x) ≲ [Formula: see text], which is tight for most inputs. The constants a and b, as well as many properties of  P(x), can be predicted with minimal knowledge of the map. We explore this strong bias towards simple outputs in systems ranging from the folding of RNA secondary structures to systems of coupled ordinary differential equations to a stochastic financial trading model.

  13. Débito cardíaco e fração de ejeção fetal por meio do spatio-temporal image correlation (STIC: comparação entre fetos masculinos e femininos Fetal cardiac output and ejection fraction by spatio-temporal image correlation (STIC: comparison between male and female fetuses

    Directory of Open Access Journals (Sweden)

    Christiane Simioni

    2012-06-01

    Full Text Available OBJETIVO: Comparar do débito cardíaco (DC e a fração de ejeção (FE do coração de fetos masculinos e femininos obtidos por meio da ultrassonografia tridimensional, utilizando o spatio-temporal image correlation (STIC. MÉTODOS: Realizou-se um estudo de corte transversal com 216 fetos normais, entre 20 a 34 semanas de gestação, sendo 108 masculinos e 108 femininos. Os volumes ventriculares no final da sístole e diástole foram obtidos por meio do STIC, sendo as avaliações volumétricas realizadas pelo virtual organ computer-aided analysis (VOCAL com rotação de 30º. Para o cálculo do DC utilizou-se a fórmula: DC= volume sistólico/frequência cardíaca fetal, enquanto que para a FE utilizou-se a fórmula: FE= volume sistólico/volume diastólico final. O DC (combinado, feminino e masculino e a FE (masculina e feminina foram comparadas utilizando-se o teste t não pareado e ANCOVA. Foram criados gráficos de dispersão com os percentis 5, 50 e 95. RESULTADOS: A média do DC combinado, DC direito, DC esquerdo, FE direita e FE esquerda, para feminino e masculino, foram 240,07 mL/min; 122,67 mL/min; 123,40 mL/min; 72,84%; 67,22%; 270,56 mL/min; 139,22 mL/min; 131,34 mL/min; 70,73% e 64,76%, respectivamente; sem diferença estatística (P> 0,05. CONCLUSÕES: O DC e a FE fetal obtidos por meio da ultrassonografia tridimensional (STIC não apresentaram diferença significativa em relação ao gênero.OBJECTIVE: To compare the cardiac output (CO and ejection fraction (EF of the heart of male and female fetuses obtained by 3D-ultrasonography using spatio-temporal image correlation (STIC. METHODS: We conducted a cross-sectional study with 216 normal fetuses, between 20 and 34 weeks of gestation, 108 male and 108 female. Ventricular volumes at the end of systole and diastole were obtained by STIC, and the volumetric assessments performed by the virtual organ computer-aided analysis (VOCAL rotated 30º. To calculate the DC used the formula

  14. Estimativa não-invasiva do débito cardíaco durante o exercício a partir de impedância cardiográfica e consumo de oxigênio em idosos Non-invasive estimate of cardiac output during exercise based on impedance cardiography and oxygen uptake in the elderly

    Directory of Open Access Journals (Sweden)

    Maurício Nunes Rodrigues

    2007-01-01

    Full Text Available OBJETIVO: O presente estudo analisou a concordância entre as estimativas do débito cardíaco (Q geradas por dois métodos indiretos e sua aplicabilidade em 54 homens e 77 mulheres (60-90 anos. MÉTODOS: Os indivíduos realizaram um teste cardiopulmonar de exercício progressivo máximo em ciclo-ergômetro. O Q foi estimado a partir do consumo de oxigênio e da impedância cardiográfica a 50% e 100% da carga máxima alcançada no teste (Wmáx. Os limites de concordância e as diferenças médias (vieses foram avaliados segundo a metodologia proposta por Bland e Altman, enquanto a relação entre os métodos foi analisada por regressão linear e correlação intraclasse (ICC. RESULTADOS: Na carga equivalente a 50% Wmáx, a diferença entre as médias dos métodos foi de -0,58 L•min-1 (6,3% menor para a medida da impedância, e o limite de concordância de ± 2,54 L•min-1 (24,7%. Em 100% Wmáx, a diferença foi de 1,03 L•min-1 (8,5% maior para a medida da impedância, com um limite de concordância de ± 3,35 L•min-1 (27,6%. Os valores de ICC e as curvas de regressão obtidas entre os métodos foram: Qimp=1,82+0,75Q VO2 (r²=0,765, pOBJECTIVE: This study assessed the agreement between cardiac output (Q measurements generated by two indirect methods and their applicability in 54 men e 77 women (aged 60-90. METHODS: The subjects performed a cardiopulmonary test with incremental to maximal exercise on a cycle-ergometer. "Q" was estimated based on oxygen uptake and on impedance cardiography at 50% and 100% of the maximal workload (Wmax reached during the test. The limits of agreement and mean differences (biases were estimated using the methodology proposed by Bland-Altman, whereas the relationship between the methods was analyzed by linear regression and intra-class correlation (ICC. RESULTS: For the load equivalent do 50% of Wmax, the bias between the means of the two methods was -0.58 L•min-1 (6.3% smaller for the impedance measurement

  15. Comparative cardiac toxicity of anthracyclines in vitro and in vivo in the mouse.

    Directory of Open Access Journals (Sweden)

    Stefano Toldo

    Full Text Available PURPOSE: The antineoplastic efficacy of anthracyclines is limited by their cardiac toxicity. In this study, we evaluated the toxicity of doxorubicin, non-pegylated liposomal-delivered doxorubicin, and epirubicin in HL-1 adult cardiomyocytes in culture as well as in the mouse in vivo. METHODS: The cardiomyocytes were incubated with the three anthracyclines (1 µM to assess reactive oxygen generation, DNA damage and apoptotic cell death. CF-1 mice (10/group received doxorubicin, epirubicin or non-pegylated liposomal-doxorubicin (10 mg/kg and cardiac function was monitored by Doppler echocardiography to measure left ventricular ejection fraction (LVEF, heart rate (HR and cardiac output (CO both prior to and 10 days after drug treatment. RESULTS: In HL-1 cells, non-pegylated liposomal-doxorubicin generated significantly less reactive oxygen species (ROS, as well as less DNA damage and apoptosis activation when compared with doxorubicin and epirubicin. Cultured breast tumor cells showed similar sensitivity to the three anthracyclines. In the healthy mouse, non-pegylated liposomal doxorubicin showed a minimal and non-significant decrease in LVEF with no change in HR or CO, compared to doxorubicin and epirubicin. CONCLUSION: This study provides evidence for reduced cardiac toxicity of non-pegylated-liposomal doxorubicin characterized by attenuation of ROS generation, DNA damage and apoptosis in comparison to epirubicin and doxorubicin.

  16. HAEMODYNAMIC RESPONSE DURING EXERCISE TESTING IN PATIENTS WITH CORONARY ARTERY DISEASE UNDERGOING A CARDIAC REHABILITATION PROGRAMME

    Directory of Open Access Journals (Sweden)

    J. Siebert

    2011-09-01

    Full Text Available Haemodynamic monitoring during exercise testing is seldom used during cardiac rehabilitation. The aim was to evaluate haemodynamic changes using the cardiac impedance method during exercise testing in patients after percutaneous coronary interventions and coronary artery bypass grafting during cardiac rehabilitation. Thirty (25 M; 5 F patients were included in the programme. The group was divided according to ejection fraction (EF: low – below 50% normal – equal to or above 50%. The exercise test was performed simultaneously with a four-electrode impedance cardiogram before and after rehabilitation. ECG, blood pressure, thoracic impedance, first derivative dz/dt, stroke volume (SV and cardiac output were recorded. Contractility index (Heather index – HI and vascular peripheral resistance were calculated. The pattern of haemodynamic changes was normal in 24 patients. The deflection points for HI and SV trend patterns were observed among patients with low EF. The contractility index decreased 90 s before maximal exercise and after the next 30-60 s a deflection point was observed in SV curve trends. In 24 patients with normal EF the contractility index trends did not decrease and SV trends increased until the end of exercise or a deflection point was not noted. The deflection points of the contractility index and SV curves were observed before the clinical indications for exercise test termination appeared in patients with a low ejection fraction. Impedance cardiography may indicate the threshold of the workload during real-time exercise testing.

  17. Cardiac conduction system

    Science.gov (United States)

    The cardiac conduction system is a group of specialized cardiac muscle cells in the walls of the heart that send signals to the ... contract. The main components of the cardiac conduction system are the SA node, AV node, bundle of ...

  18. Three-dimensional display and measurement of cardiac dynamic indexes from MR images

    International Nuclear Information System (INIS)

    Kono, M.; Matsuo, M.; Yamasaki, K.; Banno, T.; Toriwaki, J.; Yokoi, S.; Oshita, H.

    1986-01-01

    The cardiac dynamic index, to which such variables as cardiac output, ejection fraction, and wall motion contribute, is routinely determined using various modalities such as angiography, radionuclide imaging, US, and x-ray CT. Each of these modalities, however, has some disadvantages in regard to evaluating the cardiac dynamic index. The authors have obtained precise multidirectional projection images of the heart by means of computer graphics and reformatted data of cardiac MR images obtained with cardiac gating. The contiguous coronal MR images of the heart are made at an interimage distance of 5 mm. In each section, five or six cardiac images can be obtained, depending on the systolic or diastolic phase. These images are stored in a computer, and a three-dimensional display of the heart with biocular observation and with multiplex holograms is made possible with computer graphics. Three-dimensional measurement of the cardiac index is now being attempted, including cardiac output, ejection fraction, and wall motion

  19. A Statistical Representation of Pyrotechnic Igniter Output

    Science.gov (United States)

    Guo, Shuyue; Cooper, Marcia

    2017-06-01

    The output of simplified pyrotechnic igniters for research investigations is statistically characterized by monitoring the post-ignition external flow field with Schlieren imaging. Unique to this work is a detailed quantification of all measurable manufacturing parameters (e.g., bridgewire length, charge cavity dimensions, powder bed density) and associated shock-motion variability in the tested igniters. To demonstrate experimental precision of the recorded Schlieren images and developed image processing methodologies, commercial exploding bridgewires using wires of different parameters were tested. Finally, a statistically-significant population of manufactured igniters were tested within the Schlieren arrangement resulting in a characterization of the nominal output. Comparisons between the variances measured throughout the manufacturing processes and the calculated output variance provide insight into the critical device phenomena that dominate performance. Sandia National Laboratories is a multi-mission laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's NNSA under contract DE-AC04-94AL85000.

  20. Perioperative Rosuvastatin in Cardiac Surgery.

    Science.gov (United States)

    Zheng, Zhe; Jayaram, Raja; Jiang, Lixin; Emberson, Jonathan; Zhao, Yan; Li, Qi; Du, Juan; Guarguagli, Silvia; Hill, Michael; Chen, Zhengming; Collins, Rory; Casadei, Barbara

    2016-05-05

    Complications after cardiac surgery are common and lead to substantial increases in morbidity and mortality. Meta-analyses of small randomized trials have suggested that perioperative statin therapy can prevent some of these complications. We randomly assigned 1922 patients in sinus rhythm who were scheduled for elective cardiac surgery to receive perioperative rosuvastatin (at a dose of 20 mg daily) or placebo. The primary outcomes were postoperative atrial fibrillation within 5 days after surgery, as assessed by Holter electrocardiographic monitoring, and myocardial injury within 120 hours after surgery, as assessed by serial measurements of the cardiac troponin I concentration. Secondary outcomes included major in-hospital adverse events, duration of stay in the hospital and intensive care unit, left ventricular and renal function, and blood biomarkers. The concentrations of low-density lipoprotein cholesterol and C-reactive protein after surgery were lower in patients assigned to rosuvastatin than in those assigned to placebo (PSTICS ClinicalTrials.gov number, NCT01573143.).

  1. Detection of inadvertent catheter movement into the coronary sinus ostium or middle cardiac vein by real-time impedance monitoring prior to radiofrequency ablation in the right atrial posteroseptal region.

    Science.gov (United States)

    Pollak, Scott J; Seckel, Heather; Monir, Joseph; Ebra, George; Monir, George

    2012-09-01

    The objective of this study was to evaluate the use of continuous catheter impedance monitoring prior to ablation to facilitate differentiation of the coronary sinus ostium (CSO) and the middle cardiac vein (MCV) from the right atrial posteroseptal region (RPS). Empiric observations have suggested that continuous catheter impedance monitoring could differentiate the CSO and MCV from the RPS region. Radiofrequency ablation in the MCV or coronary sinus has been associated with coronary artery injury. Differentiation of these areas may be difficult with either fluoroscopy or electrogram characteristics. Continuous impedance measurements using a 4-mm Navistar (Biosense Webster) ablation catheter were conducted in 17 consecutive patients undergoing ablation for supraventricular tachycardia. The average impedance value was recorded at the right atrial septum (RS) posterior to the bundle of His, the RPS region, within 1 cm inside the CSO and in the MCV. These areas were confirmed and demarcated with 3-D mapping and biplane fluoroscopy. A significant increase in impedance was observed between the CSO (X = 146.6 ± 24.8) and RPS [Formula: see text] regions (p regions. Continuous impedance measurements during mapping can facilitate differentiation of catheter locations inside the CSO and MCV from extracoronary sinus regions. This may reduce the risk of inadvertent coronary artery damage during the ablation procedure.

  2. Output

    DEFF Research Database (Denmark)

    Mehlsen, Camilla

    2010-01-01

    Hvad får vi egentlig ud af internationale komparative undersøgelser som PISA, PIRLS og TIMSS? Hvordan påvirker de dansk uddannelsespolitik? Asterisk har talt med tre forskere med ekspertise på området.......Hvad får vi egentlig ud af internationale komparative undersøgelser som PISA, PIRLS og TIMSS? Hvordan påvirker de dansk uddannelsespolitik? Asterisk har talt med tre forskere med ekspertise på området....

  3. Pre- and Postoperative Accuracy and Safety of a Real-Time Continuous Glucose Monitoring System in Cardiac Surgical Patients : A Randomized Pilot Study

    NARCIS (Netherlands)

    Logtenberg, Susan J.; Kleefstra, Nanne; Snellen, Ferdinand T.; Groenier, Klaas H.; Slingerland, Robbert J.; Nierich, Arno P.; Bilo, Henk J.

    Background: Our objective was to evaluate the accuracy and safety of a real-time (RT) continuous glucose monitoring system (CGMS) in patients before and after cardiothoracic surgery and to investigate whether activation of the alarm function of the RT-CGMS had an effect on glucose control. Methods:

  4. An airline cardiac arrest program.

    Science.gov (United States)

    O'Rourke, M F; Donaldson, E; Geddes, J S

    1997-11-04

    As many as 1000 lives are lost annually from cardiac arrest in commercial aircraft. Ventricular fibrillation (VF), the most common mechanism, can be treated effectively only with prompt defibrillation, whereas the current policy of most airlines is to continue cardiopulmonary resuscitation pending aircraft diversion. The objective of this study was to assess the impact of making semiautomatic external defibrillators (AEDs) available for use on airline passengers with cardiac arrest. AEDs were installed on international Qantas aircraft and at major terminals, selected crew were trained in their use, and all crew members were trained in cardiopulmonary resuscitation. Supervision was provided by medical volunteers or (remotely) by airline physicians. During a 64-month period, AEDs were used on 109 occasions: 63 times for monitoring an acutely ill passenger and 46 times for cardiac arrest. Twenty-seven episodes of cardiac arrest occurred in aircraft, often (11 of 27 [41%]) unwitnessed, and they were usually (21 of 27 [78%]) associated with asystole or pulseless idioventricular rhythm. All 19 arrests in terminals were witnessed; VF was present in 17 (89%). Overall, defibrillation was initially successful in 21 of 23 cases (91%). Long-term survival from VF was achieved in 26% (2 of 6 in aircraft and 4 of 17 in terminals). The ability to monitor cardiac rhythm aided decisions on diversion, which was avoided in most passengers with asystole or idioventricular rhythm. AEDs in aircraft and terminals, with appropriate crew training, are helpful in the management of cardiac emergencies. Survival from VF is practicable and is comparable with the most effective prehospital ambulance emergency services. Costly aircraft diversions can be avoided in clearly futile situations, enhancing the cost-effectiveness of the program.

  5. Cardiac pacemaker

    International Nuclear Information System (INIS)

    Kolenik, S.A.

    1976-01-01

    The construction of a cardiac pacemaker is described which is characterized by particularly small dimensions, small weight and long life duration. The weight is under 100g, the specific weight under 1.7. Mass inertia forces which occur through acceleration and retardation processes, thus remain below the threshold values, above which one would have to reckon with considerable damaging of the surrounding body tissue. The maintaining of small size and slight weight is achieved by using an oscillator on COSMOS basis, where by considerably lower energy consumption, amongst others the lifetimes of the batteries used - a lithium anode with thionyl chloride electrolyte - is extended to over 5 years. The reliability can be increased by the use of 2 or more batteries. The designed dimension are 20x60x60 mm 3 . (ORU/LH) [de

  6. Avaliação da correlação entre o dióxido de carbono expirado e o débito cardíaco em pacientes submetidos à cirurgia cardíaca com circulação extracorpórea Evaluación de la correlación entre el dióxido de carbono expirado y el débito cardíaco en pacientes sometidos a la cirugía cardíaca con circulación extracorpórea Correlation between end-tidal carbon dioxide levels and cardiac output during cardiac surgery with cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Karina Takesaki Miyaji

    2004-10-01

    reflects pulmonary blood perfusion, thus cardiac output (CO. This study aimed at evaluating the correlation between P ET CO2 levels and CO during cardiac surgery with cardiopulmonary bypass (CPB. METHODS: Participated in this study 25 patients submitted to coronary artery bypass grafting (CABG with CPB. End-tidal CO2 monitoring started after tracheal intubation. Cardiac output was determined by thermodilution with pulmonary artery catheter (Swan-Ganz. Carbon dioxide partial blood pressure (PaCO2 was obtained with arterial blood gases analysis. Studied parameters were evaluated in the following moments: immediately after general anesthesia induction, before cardiopulmonary bypass, at cardiopulmonary bypass completion and at surgery completion. RESULTS: Statistical analysis has not shown correlation between P ET CO2 and CO2, or between P ET CO2-PaCO2 gradient (Ga-eCO2 and CO. There has been correlation between P ET CO2, Ga-eCO2 and CO values variation as compared to baseline values before CPB, with loss of correlation after CPB until surgery completion. CONCLUSIONS: In this study, where patients submitted to cardiac surgery with CPB were evaluated, ventilation/perfusion changes throughout the procedure might have been the factors determining decreased correlation between cardiac output and end tidal CO2.

  7. Selective arterialization of a cardiac vein in a model of cardiac microangiopathy and macroangiopathy in sheep.

    Science.gov (United States)

    Resetar, Michaela Elisabeth; Ullmann, Cris; Broeske, Petra; Ludwig-Schindler, Kristin; Doll, Nicolas K; Salameh, Aida; Dhein, Stefan; Mohr, Friedrich W

    2007-05-01

    Some patients with significant arteriosclerosis of the heart are not amenable to revascularization of a coronary artery because they have a combination of microangiopathy and significant macroangiopathy. We investigated the benefit of arterialization of a cardiac vein under these circumstances in an acute animal model. In the hearts of 8 sheep, microspheres were injected into the left coronary artery; 60 minutes later, a stenosis of the left anterior descending artery was performed. After 45 minutes, retrograde venous revascularization was performed by sewing the left internal thoracic artery to the concomitant vein of the left anterior descending artery in a beating-heart technique. For flow reversal, the vein was ligated proximally to the anastomosis. The efficiency of the bypass graft was evaluated by coronary angiography and flow measurement. Cardiac output, electrocardiography, and mean arterial blood pressure were assessed in each phase of the experiment. The ischemic state of the myocardium was confirmed by a significant decrease of cardiac output, stroke volume, and mean arterial blood pressure, and a significant elevation of the ST segment in the electrocardiography. After retrograde venous revascularization was established, cardiac output and stroke volume increased and ST elevations decreased. The grafts showed adequate flow (26.15 +/- 2.08 mL/min), and reversed blood flow in the grafted vein was proved by coronary angiography. Retrograde venous revascularization is possible and improves cardiac function in a state of acute ischemia caused by a combination of microangiopathy and macroangiopathy.

  8. Conventional hemofiltration during cardiopulmonary bypass increases the serum lactate level in adult cardiac surgery

    Directory of Open Access Journals (Sweden)

    Rabie Soliman

    2016-01-01

    Full Text Available Objective: To evaluate the effect of hemofiltration during cardiopulmonary bypass on lactate level in adult patients who underwent cardiac surgery. Design: An observational study. Setting: Prince Sultan cardiac center, Riyadh, Saudi Arabia. Participants: The study included 283 patients classified into two groups: Hemofiltration group (n=138, hemofiltration was done during CPB. Control group (n = 145, patients without hemofiltration. Interventions: Hemofiltration during cardiopulmonary bypass. Measurements and Main Results: Monitors included hematocrit, lactate levels, mixed venous oxygen saturation, amount of fluid removal during hemofiltration and urine output. The lactate elevated in group H than group C (P < 0.05, and the PH showed metabolic acidosis in group H (P < 0.05. The mixed venous oxygen saturation decreased in group H than group C (P < 0.05. The number of transfused packed red blood cells was lower in group H than group C (P < 0.05. The hematocrit was higher in group H than group C (P < 0.05. The urine output was lower in group H than group C (P < 0.05. Conclusions: Hemofiltration during cardiopulmonary bypass leads to hemoconcentration, elevated lactate level and increased inotropic support. There are some recommendations for hemofiltration: First; Hemofiltration should be limited for patients with impaired renal function, positive fluid balance, reduced response to diuretics or prolonged bypass time more than 2 hours. Second; Minimal amount of fluids should be administered to maintain adequate cardiac output and reduction of priming volumes is preferable to maintain controlled hemodilution. Third; it should be done before weaning of or after cardiopulmonary bypass and not during the whole time of cardiopulmonary bypass.

  9. Research management and research output

    Directory of Open Access Journals (Sweden)

    Anita Bosch

    2011-12-01

    Full Text Available Purpose: A study was conducted at two merged South African higher education institutions to determine which management factors, as identified in a literature study as well as through a factor analysis of survey data, were predictive of the dependent variable 'research output'. Problem investigated: Research output contributes to creating sustainability of knowledge of management sciences and therefore the active management of research is in the interest of progressive universities. Research management related activities are usually associated with measurable targets, detailed plans, rigorous evaluation and decisive action - all of which are observable (perhaps programmable behaviour also referred to as tangible factors. Authors argue that the tangible factors of any successful institution can be copied, technology can be bought, and in theory you should have an instantly thriving research institution. It is, however, clear that although many institutions have exactly the same technology and structure as their successful competitors, they still fail to succeed in increasing research output. Design and Research methodology or approach: A survey was distributed to n=411 and yielded a 49.6% response rate. A confirmatory reliability analysis as well as a factor analysis was conducted. Findings/implications: The empirical model that was derived through a factor analysis strengthens the argument that both tangible and intangible factors exist in a research environment. Tangible and intangible factors play a different role in predicting research output. The tangible factors are predictors of research output for non-research-active academics. The theoretical research output prediction model highlights predictors such as 'professional activities' and 'individual skills and competence' for specific groupings. The theoretical model indicates that the factors that predict research output are largely intrinsic to a researcher but could also be supported by

  10. Anesthesia-Associated Relative Hypovolemia: Mechanisms, Monitoring, and Treatment Considerations

    Directory of Open Access Journals (Sweden)

    Jessica Noel-Morgan

    2018-03-01

    Full Text Available Although the utility and benefits of anesthesia and analgesia are irrefutable, their practice is not void of risks. Almost all drugs that produce anesthesia endanger cardiovascular stability by producing dose-dependent impairment of cardiac function, vascular reactivity, and compensatory autoregulatory responses. Whereas anesthesia-related depression of cardiac performance and arterial vasodilation are well recognized adverse effects contributing to anesthetic risk, far less emphasis has been placed on effects impacting venous physiology and venous return. The venous circulation, containing about 65–70% of the total blood volume, is a pivotal contributor to stroke volume and cardiac output. Vasodilation, particularly venodilation, is the primary cause of relative hypovolemia produced by anesthetic drugs and is often associated with increased venous compliance, decreased venous return, and reduced response to vasoactive substances. Depending on factors such as patient status and monitoring, a state of relative hypovolemia may remain clinically undetected, with impending consequences owing to impaired oxygen delivery and tissue perfusion. Concurrent processes related to comorbidities, hypothermia, inflammation, trauma, sepsis, or other causes of hemodynamic or metabolic compromise, may further exacerbate the condition. Despite scientific and technological advances, clinical monitoring and treatment of relative hypovolemia still pose relevant challenges to the anesthesiologist. This short perspective seeks to define relative hypovolemia, describe the venous system’s role in supporting normal cardiovascular function, characterize effects of anesthetic drugs on venous physiology, and address current considerations and challenges for monitoring and treatment of relative hypovolemia, with focus on insights for future therapies.

  11. Simulation data mapping in virtual cardiac model.

    Science.gov (United States)

    Jiquan, Liu; Jingyi, Feng; Duan, Huilong; Siping, Chen

    2004-01-01

    Although 3D heart and torso model with realistic geometry are basis of simulation computation in LFX virtual cardiac model, the simulation results are mostly output in 2D format. To solve such a problem and enhance the virtual reality of LFX virtual cardiac model, the methods of voxel mapping and vertex project mapping were presented. With these methods, excitation isochrone map (EIM) was mapped from heart model with realistic geometry to real visible man heart model, and body surface potential map (BSPM) was mapped from torso model with realistic geometry to real visible man body surface. By visualizing in the 4Dview, which is a real-time 3D medical image visualization platform, the visualization results of EIM and BSPM simulation data before and after mapping were also provided. According to the visualization results, the output format of EIM and BSPM simulation data of LFX virtual cardiac model were extended from 2D to 4D (spatio-temporal) and from cardiac model with realistic geometry to real cardiac model, and more realistic and effective simulation was achieved.

  12. Application of transpulmonary thermodilution monitoring (PiCCO) in patient with neurogenic pulmonary edema and acute obstructive hydrocephalus due to a central neurocytoma: A case report

    OpenAIRE

    Ryoichi Iwata; Kunikazu Yoshimura; Yoko Fujita; Tatsuo Uesaka; Hideyuki Oshige; Akio Asai

    2017-01-01

    Neurogenic pulmonary edema (NPE) is an acute life-threatening complication associated with many forms of central nervous system injury. Its pathophysiology is still debated. We report a patient with acute obstructive hydrocephalus due to a central neurocytoma who also had NPE, for which serial transpulmonary thermodilution monitoring (PiCCO) was performed. Insertion of the PiCCO, which provides information about the patient's cardiac output, preload status and amount of lung water, revealed a...

  13. Incidencia de eventos vasculares mayores después de cirugía no cardiaca: impacto del monitoreo perioperatorio con troponina y electrocardiograma Incidence of major vascular events after cardiac surgery: impact of preoperative monitoring with troponin and electrocardiogram

    Directory of Open Access Journals (Sweden)

    Sandra M Quiroga

    2009-06-01

    led to an increased risk of major vascular events among patients undergoing non-cardiac surgery. Troponin and electrocardiogram monitoring would further identify these major vascular events. Methods: we prospectively collected data on elegible patients (non-selected individuals aged 45 or older undergoing non-cardiac surgery under general or regional anesthesia in two hospitals in Bucaramanga, with expected length of stay longer than 24 hours during a time-interrupted series, before and after postoperative diagnostic monitoring (blinded assessment of troponin T and electrocardiograms ignoring clinical data. For the period before the intervention (usual clinical care, two independent reviewers extracted clinical information from clinical histories (of all eligible patients from 3 randomly-selected months of 2005. For the period after diagnostic monitoring, we followed 100 consecutive eligible patients. Primary outcome was a composite of major vascular events within hospital, including myocardial infarction (defined as any troponin elevation associated with electrocardiographic changes suggesting ischemia, regardless of symptoms. Results: we included 534 clinical charts and 100 prospective surgical patients (mean age 62.2, SD 12.9 years; 56% women. The more frequent surgical procedures were orthopedics (26.8% followed by abdominal (20.2%. The incidence of major vascular events recorded in clinical charts was 2.8%, compared with 7% among monitored patients (p=0,071. All four myocardial infarctions identified among the later group were silent. Conclusion: postoperative monitoring with troponin and electrocardiography identified a higher proportion of major vascular events, mainly silent myocardial infarctions.

  14. Fiberoptic monitoring of central venous oxygen saturation (PediaSat in small children undergoing cardiac surgery: continuous is not continuous [v3; ref status: indexed, http://f1000r.es/3qt

    Directory of Open Access Journals (Sweden)

    Francesca G. Iodice

    2014-06-01

    Full Text Available Background: Monitoring of superior vena cava saturation (ScvO2 has become routine in the management of pediatric patients undergoing cardiac surgery. The objective of our study was to evaluate the correlation between continuous ScvO2 by the application of a fiber-optic oximetry catheter (PediaSat and intermittent ScvO2 by using standard blood gas measurements. These results were compared to those obtained by cerebral near infrared spectroscopy (cNIRS. Setting: Tertiary pediatric cardiac intensive care unit (PCICU. Methods and main results: A retrospective study was conducted in consecutive patients who were monitored with a 4.5 or 5.5 F PediaSat catheter into the right internal jugular vein. An in vivo calibration was performed once the patient was transferred to the PCICU and re-calibration took place every 24 hours thereafter. Each patient had a NIRS placed on the forehead. Saturations were collected every 4 hours until extubation. Ten patients with a median age of 2.2 (0.13-8.5 years and a weight of 12.4 (3.9-24 kg were enrolled. Median sampling time was 32 (19-44 hours: 64 pairs of PediaSat and ScVO2 saturations showed a poor correlation (r=0.62, 95% CI 44-75; p<0.0001 and Bland Altman analysis for repeated measures showed an average difference of 0.34 with a standard deviation of 7,9 and 95% limits of agreement from -15 to 16. Thirty-six pairs of cNIRS and ScVO2 saturations showed a fair correlation (r=0.79, 95% CI 0.60-0.89; p<0.0001 an average difference of -1.4 with a standard deviation of 6 and 95% limits of agreement from -13 to 10. Analysis of median percentage differences between PediaSat and ScvO2 saturation over time revealed that, although not statistically significant, the change in percentage saturation differences was clinically relevant after the 8th hour from calibration (from -100 to +100%. Conclusion: PediaSat catheters showed unreliable performance in our cohort. It should be further investigated whether repeating

  15. Débito cardíaco diminuído: revisão sistemática das características definidoras Débito cardíaco disminuído: revisión sistemática de las características definidoras Decreased cardiac output: a systematic review of the defining characteristics

    Directory of Open Access Journals (Sweden)

    Vanessa de Souza

    2011-01-01

    explorada. Se constató la importancia del examen físico, la utilización de técnicas menos invasivas y la necesidad de revisar las características definidoras propuestas a fin de proporcionar claridad y objetividad en la identificación de ese diagnóstico de enfermeríaOBJECTIVES: To characterize the scientific articles related to the NANDA-I nursing diagnosis, decreased cardiac output. Verify those articles that describe the behavior of the defining characteristics of this diagnosis, identifying those that occur with the highest frequency. METHODS: A systematic review of literature published between the years 1985 - 2008 was conducted, using the following databases: Lilacs, SciELO, EMBASE, Medline, Pubmed and Cochrane. RESULTS: The sample included 13 articles which identified 50 defining characteristics. Ten characteristics were noted to occur with high frequency: altered heart rate/rhythm, dyspnea, labile blood pressure, rales, oliguria / anuria, edema, cold skin, fatigue / weakness, decreased peripheral pulses and decreased peripheral perfusion. CONCLUSION: This subject has not been explored in depth in the literature. The importance of physical examination, the use of less invasive techniques, and the need to review the proposed defining characteristics to provide clarity and objectivity in the identification of this nursing diagnosis was identified

  16. The Western Denmark Cardiac Computed Tomography Registry

    DEFF Research Database (Denmark)

    Nielsen, Lene Hüche; Nørgaard, Bjarne Linde; Tilsted, Hans-Henrik

    2015-01-01

    BACKGROUND: As a subregistry to the Western Denmark Heart Registry (WDHR), the Western Denmark Cardiac Computed Tomography Registry (WDHR-CCTR) is a clinical database established in 2008 to monitor and improve the quality of cardiac computed tomography (CT) in Western Denmark. OBJECTIVE: We...... positive and negative predictive values for both university (96%/99%) and nonuniversity centers (97%/99%). CONCLUSION: WDHR-CCTR provides ongoing prospective registration of all cardiac CTs performed in Western Denmark since 2008. Overall, the registry data have a high degree of completeness and validity...

  17. Temperate climate - Innovative outputs nexus

    NARCIS (Netherlands)

    Coccia, M.

    2014-01-01

    Technological change is a vital human activity that interacts with geographic factors and environment. The purpose of the study here is to analyse the relationship between geo-climate zones of the globe and technological outputs in order to detect favourable areas that spur higher technological

  18. Remote input/output station

    CERN Multimedia

    1972-01-01

    A general view of the remote input/output station installed in building 112 (ISR) and used for submitting jobs to the CDC 6500 and 6600. The card reader on the left and the line printer on the right are operated by programmers on a self-service basis.

  19. Kilder til output-legitimitet

    DEFF Research Database (Denmark)

    Pedersen, Morten Jarlbæk

    2016-01-01

    Diskussioner om legitimitet i den Europæiske Union bygger ofte på det teoretiske skel mellem output-legitimitet og andre former for legitimitet. Dette skyldes ikke mindst, at netop Unionens evne til at levere reale løsninger på reale problemer er en væsentlig – hvis ikke den væsentligste – kilde ...

  20. World Input-Output Network.

    Directory of Open Access Journals (Sweden)

    Federica Cerina

    Full Text Available Production systems, traditionally analyzed as almost independent national systems, are increasingly connected on a global scale. Only recently becoming available, the World Input-Output Database (WIOD is one of the first efforts to construct the global multi-regional input-output (GMRIO tables. By viewing the world input-output system as an interdependent network where the nodes are the individual industries in different economies and the edges are the monetary goods flows between industries, we analyze respectively the global, regional, and local network properties of the so-called world input-output network (WION and document its evolution over time. At global level, we find that the industries are highly but asymmetrically connected, which implies that micro shocks can lead to macro fluctuations. At regional level, we find that the world production is still operated nationally or at most regionally as the communities detected are either individual economies or geographically well defined regions. Finally, at local level, for each industry we compare the network-based measures with the traditional methods of backward linkages. We find that the network-based measures such as PageRank centrality and community coreness measure can give valuable insights into identifying the key industries.

  1. Advanced Cardiovascular Monitoring

    NARCIS (Netherlands)

    de Waal, E.E.C.

    2009-01-01

    The Frank-Starling curve (the curvilinear relation between cardiac output (CO) and preload) can be used for optimalization of the blood circulation and tissue oxygenation, in order to decrease morbidity and mortality in high risk surgery and critically ill patients. Measurement of CO and preload

  2. Dynamic NMR cardiac imaging in a piglet

    Energy Technology Data Exchange (ETDEWEB)

    Doyle, M.; Rzedzian, R.; Mansfield, P. (Nottingham Univ. (UK). Dept. of Physics); Coupland, R.E. (Nottingham Univ. (UK). Queen' s Medical Centre)

    1983-12-01

    NMR echo-planar imaging (EPI) has been used in a real-time mode to visualise the thorax of a live piglet. Moving pictures are available on an immediate image display system which demonstrates dynamic cardiac function. Frame rates vary from one per cardiac cycle in a prospective stroboscopic mode with immediate visual output to a maximum of 10 frames per second yielding up to six looks in one piglet heart cycle, but using a visual playback mode. A completely new system has been used to obtain these images, features of which include a probe assembly with 22 cm access and an AP400 array processor for real-time data processing.

  3. Quantification of a Low-Cost Stretchable Conductive Sensor Using an Expansion/Contraction Simulator Machine: A Step towards Validation of a Noninvasive Cardiac and Respiration Monitoring Prototype

    Directory of Open Access Journals (Sweden)

    Elham Shabani Varaki

    2017-10-01

    Full Text Available The use of wearable sensors in health monitoring is increasing dramatically, largely due to their convenience and low-cost. Understanding the accuracy of any given sensor is paramount to avoid potential misdiagnosis. Commercially available electro-resistive band (ERB sensors have been integrated into several newly developed wearable devices with a view to using these sensors to monitor a range of respiratory and cardiovascular metrics. Quantification of the ERBs is a necessary to step towards validation of these prototypes, as it provides valuable information, which could be exploited for compensation and ultimately, for improvement of their performance. Here, we present an analysis of the ERB sensors using an expansion/contraction simulator machine. Using the developed rig, the characteristics of four ERBs were compared with a linear displacement sensor (string potentiometer during continuous use over the course of four-and-a-half days to investigate the error and nonlinearity of the ERBs. The analysis of the recorded data includes calculation and comparison of the total harmonic distortions of the two sensors to quantify ERB nonlinearity. Moreover, comparisons between the peak-to-peak voltages and signal-to-noise ratios of the ERB and string potentiometer demonstrate the effect nonlinearity on these factors. This paper demonstrates the nonlinearity of ERBs and highlights the implications for their use in practice.

  4. Long-Term Monitoring of Physical Behavior Reveals Different Cardiac Responses to Physical Activity among Subjects with and without Chronic Neck Pain

    Directory of Open Access Journals (Sweden)

    David M. Hallman

    2015-01-01

    Full Text Available Background. We determined the extent to which heart rate variability (HRV responses to daily physical activity differ between subjects with and without chronic neck pain. Method. Twenty-nine subjects (13 women with chronic neck pain and 27 age- and gender-matched healthy controls participated. Physical activity (accelerometry, HRV (heart rate monitor, and spatial location (Global Positioning System (GPS were recorded for 74 hours. GPS data were combined with a diary to identify periods of work and of leisure at home and elsewhere. Time- and frequency-domain HRV indices were calculated and stratified by period and activity type (lying/sitting, standing, or walking. ANCOVAs with multiple adjustments were used to disclose possible group differences in HRV. Results. The pain group showed a reduced HRV response to physical activity compared with controls (p=.001, according to the sympathetic-baroreceptor HRV index (LF/HF, ratio between low- and high-frequency power, even after adjustment for leisure time physical activity, work stress, sleep quality, mental health, and aerobic capacity (p=.02. The parasympathetic response to physical activity did not differ between groups. Conclusions. Relying on long-term monitoring of physical behavior and heart rate variability, we found an aberrant sympathetic-baroreceptor response to daily physical activity among subjects with chronic neck pain.

  5. Are echocardiography, telemetry, ambulatory electrocardiography monitoring, and cardiac enzymes in emergency department patients presenting with syncope useful tests? A preliminary investigation.

    Science.gov (United States)

    Chiu, David T; Shapiro, Nathan I; Sun, Benjamin C; Mottley, J Lawrence; Grossman, Shamai A

    2014-07-01

    Prior studies of admitted geriatric syncope patients suggest that diagnostic tests affect management telemetry, ambulatory electrocardiography monitoring, and troponin) were studied. Interobserver agreement as to whether test results determined the etiology of the syncope was measured using kappa (κ) values. Of 570 patients with syncope, 73 patients (8%; 95% confidence interval 7-10%) had studies that were diagnostic. One hundred fifty (26%) had echocardiography, with 33 (22%) demonstrating a likely etiology of the syncopal event, such as critical valvular disease or significantly depressed left ventricular function (κ = 0.75). On hospitalization, 330 (58%) patients were placed on telemetry, and 19 (3%) had worrisome dysrhythmias (κ = 0.66). There were 317 (55%) patients who had troponin levels drawn, of whom 19 (3%) had positive results (κ = 1); 56 (10%) patients were discharged with monitoring, with significant findings in only 2 (0.4%) patients (κ = 0.65). Although routine testing is prevalent in ED patients with syncope, the diagnostic yield is relatively low. Nevertheless, some testing, particularly echocardiography, may yield critical findings. Current efforts to reduce the cost of medical care by eliminating nondiagnostic medical testing and increasing emphasis on practicing evidence-based medicine argue for more discriminate testing when evaluating syncope. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Long-Term Monitoring of Physical Behavior Reveals Different Cardiac Responses to Physical Activity among Subjects with and without Chronic Neck Pain

    Science.gov (United States)

    Hallman, David M.; Mathiassen, Svend Erik; Lyskov, Eugene

    2015-01-01

    Background. We determined the extent to which heart rate variability (HRV) responses to daily physical activity differ between subjects with and without chronic neck pain. Method. Twenty-nine subjects (13 women) with chronic neck pain and 27 age- and gender-matched healthy controls participated. Physical activity (accelerometry), HRV (heart rate monitor), and spatial location (Global Positioning System (GPS)) were recorded for 74 hours. GPS data were combined with a diary to identify periods of work and of leisure at home and elsewhere. Time- and frequency-domain HRV indices were calculated and stratified by period and activity type (lying/sitting, standing, or walking). ANCOVAs with multiple adjustments were used to disclose possible group differences in HRV. Results. The pain group showed a reduced HRV response to physical activity compared with controls (p = .001), according to the sympathetic-baroreceptor HRV index (LF/HF, ratio between low- and high-frequency power), even after adjustment for leisure time physical activity, work stress, sleep quality, mental health, and aerobic capacity (p = .02). The parasympathetic response to physical activity did not differ between groups. Conclusions. Relying on long-term monitoring of physical behavior and heart rate variability, we found an aberrant sympathetic-baroreceptor response to daily physical activity among subjects with chronic neck pain. PMID:26557711

  7. Cardiac regeneration therapy: connections to cardiac physiology.

    Science.gov (United States)

    Takehara, Naofumi; Matsubara, Hiroaki

    2011-12-01

    Without heart transplantation, a large number of patients with failing hearts worldwide face poor outcomes. By means of cardiomyocyte regeneration, cardiac regeneration therapy is emerging with great promise as a means for restoring loss of cardiac function. However, the limited success of clinical trials using bone marrow-derived cells and myoblasts with heterogeneous constituents, transplanted at a wide range of cell doses, has led to disagreement on the efficacy of cell therapy. It is therefore essential to reevaluate the evidence for the efficacy of cell-based cardiac regeneration therapy, focusing on targets, materials, and methodologies. Meanwhile, the revolutionary innovation of cardiac regeneration therapy is sorely needed to help the millions of people who suffer heart failure from acquired loss of cardiomyocytes. Cardiac regeneration has been used only in limited species or as a developing process in the rodent heart; now, the possibility of cardiomyocyte turnover in the human heart is being revisited. In the pursuit of this concept, the use of cardiac stem/progenitor stem cells in the cardiac niche must be focused to usher in a second era of cardiac regeneration therapy for the severely injured heart. In addition, tissue engineering and cellular reprogramming will advance the next era of treatment that will enable current cell-based therapy to progress to "real" cardiac regeneration therapy. Although many barriers remain, the prevention of refractory heart failure through cardiac regeneration is now becoming a realistic possibility.

  8. Molecular In Vivo Imaging Using a Noninvasive Cardiac-Specific MLC-2v Promoter Driven Dual-Gene Recombinant Lentivirus Monitoring System.

    Directory of Open Access Journals (Sweden)

    Miao Zhang

    Full Text Available Our study aimed to demonstrate the feasibility of using the sodium/iodide symporter (NIS to monitor vascular endothelial growth factor (VEGF165 expression in vivo.We constructed a recombinant lentivirus plasmid with the MLC-2v promoter driving the sodium/iodide symporter (NIS reporter gene linked to the VEGF165 gene. Expression of NIS and VEGF gene were identified by Western blot. On days 2 and 54, 99mTc-MIBI imaging was used to evaluate changes in myocardial ischemia. Noninvasive 125I micro-SPECT/CT imaging was used to assess the expression of NIS reporter gene dynamically over the next 2 months.Western blot analysis showed that both NIS and VEGF165 were highly expressed in rat cardiomyoblast H9C2 cells transduced with Lenti-MLC-2v-NIS--VEGF165. 125I micro-SPECT/CT reporter imaging showed higher uptake in mouse myocardium transduced with Lenti-MLC-2v-VEGF165-IRES-NIS. NIS expression peaked on day 1 after transduction followed by a progressive decline to negligible levels by day 21. On day 1, mean 125I activity value in group 1 was higher than that in group 2 (P 0.05. In group 1 (test group, 99mTc-MIBI SPECT/CT revealed improvements in perfusion and wall thickening in the apical anterior wall. Mean IOD values of NIS and CD34 were significantly higher in group 1 than group 3 (P<0.05. Our study proved mean I-125 uptake was significantly correlated with mean IOD value of NIS and CD34 (P<0.05.This study demonstrates the feasibility of using the NIS gene to monitor VEGF165 expression in a mouse myocardial ischemia model.

  9. Determination of radiation-induced DNA double-strand breaks for the biological dose monitoring in cardiac computerized tomography; Bestimmung von strahleninduzierten DNA-Doppelstrangbruechen zum Monitoring der biologischen Dosis in der Herz-Computertomographie

    Energy Technology Data Exchange (ETDEWEB)

    Wegener, Jasmin

    2013-11-12

    Background and aims: X-rays cause relevant DNA damage to cells. DNA double-strand breaks (DSBs) are considered to be the most biologically significant radiation induced DNA-lesions. Recently a sensitive immunofluorescence microscopic method was developed to quantify x-ray induced DSBs as nuclear foci, even after doses as used in computed tomography. The method is based on the phosphorylation of the histone variant H2AX after formation of DSBs and distinct foci representing DSBs can be visualised. The number of foci correlates well with the delivered radiation dose. The importance of cardiac CT has increased during the last years. The radiation exposure of cardiac CT is rather high compared to other radiologic diagnostic procedures and techniques for dose-reduction receive increasing attention. In this context the purpose of this study was to determine to what extent the γ-H2AX-based method is able to measure x-ray induced DSBs in patients undergoing cardiac CT. Furthermore the objective was to evaluate whether CT-induced DSBs correlate with exposure parameters (dose length product, DLP) and to assess the influence of the scan protocols on the biological radiation damage. Materials and methods: 32 patients undergoing coronary CT angiography either using a 64-slice (n = 5: SOMATOM Sensation 64 {sup registered}) or a dual-source CT scanner (n = 27: SOMATOM Definition {sup registered}) were included in the study. Venous blood samples were taken before and 0.5 h, 2.5 h, and 24 h after the CT scan. Additional venous blood samples obtained before CT were irradiated in-vitro at various radiation doses (10 mGy, 50 mGy, 100 mGy) to obtain reference values of foci. Lymphocytes were separated and incubated with a specific γ-H2AX primary and a fluorescent secondary antibody. The number of γ-H2AX-foci was quantified using a fluorescence microscope. Every distinct focus represents one DNA-DSB. The number of radiation-induced DSBs was calculated by subtracting the foci number

  10. Dynamic Measurement of Hemodynamic Parameters and Cardiac Preload in Adults with Dengue: A Prospective Observational Study.

    Directory of Open Access Journals (Sweden)

    Vipa Thanachartwet

    Full Text Available Few previous studies have monitored hemodynamic parameters to determine the physiological process of dengue or examined inferior vena cava (IVC parameters to assess cardiac preload during the clinical phase of dengue. From January 2013 to July 2015, we prospectively studied 162 hospitalized adults with confirmed dengue viral infection using non-invasive cardiac output monitoring and bedside ultrasonography to determine changes in hemodynamic and IVC parameters and identify the types of circulatory shock that occur in patients with dengue. Of 162 patients with dengue, 17 (10.5% experienced dengue shock and 145 (89.5% did not. In patients with shock, the mean arterial pressure was significantly lower on day 6 after fever onset (P = 0.045 and the pulse pressure was significantly lower between days 4 and 7 (P50% between days 4 and 5 (P<0.05. Hypovolemic shock was observed in 9 (52.9% patients and cardiogenic shock in 8 (47.1%, with a median (interquartile range time to shock onset of 6.0 (5.0-6.5 days after fever onset, which was the median day of defervescence. Intravascular hypovolemia occurred before defervescence, whereas myocardial dysfunction occurred on the day of defervescence until 2 weeks after fever onset. Hypovolemic shock and cardiogenic shock each occurred in approximately half of the patients with dengue shock. Therefore, dynamic measures to estimate changes in hemodynamic parameters and preload should be monitored to ensure adequate fluid therapy among patients with dengue, particularly patients with dengue shock.

  11. Monitoring during Mechnical Ventilation

    Directory of Open Access Journals (Sweden)

    Dean Hess

    1996-01-01

    Full Text Available Monitoring is a continuous, or nearly continuous, evaluation of the physiological function of a patient in real time to guide management decisions, including when to make therapeutic interventions and assessment of those interventions. Pulse oximeters pass two wavelengths of light through a pulsating vascular bed and determine oxygen saturation. The accuracy of pulse oximetry is about ±4%. Capnography measures carbon dioxide at the airway and displays a waveform called the capnogram. End-tidal PCO2 represents alveolar PCO2 and is determined by the ventilation-perfusion quotient. Use of end-tidal PCO2 as an indication of arterial PCO2 is often deceiving and incorrect in critically ill patients. Because there is normally very little carbon dioxide in the stomach, a useful application of capnography is the detection of esophageal intubation. Intra-arterial blood gas systems are available, but the clinical impact and cost effectiveness of these is unclear. Mixed venous oxygenation (PvO2 or SvO2 is a global indicator of tissue oxygenation and is affected by arterial oxygen content, oxygen consumption and cardiac output. Indirect calorimetry is the calculation of energy expenditure and respiratory quotient by the measurement of oxygen consumption and carbon dioxide production. A variety of mechanics can be determined in mechanically ventilated patients including resistance, compliance, auto-peak end-expiratory pressure (PEEP and work of breathing. The static pressure-volume curve can be used to identify lower and upper infection points, which can be used to determine the appropriate PEEP setting and to avoid alveolar overdistension. Although some forms of monitoring have become a standard of care during mechanical ventilation (eg, pulse oximetry, there is little evidence that use of any monitor affects patient outcome.

  12. Potential role of telemedical service centers in managing remote monitoring data transmitted daily by cardiac implantable electronic devices: results of the early detection of cardiovascular events in device patients with heart failure (detecT-Pilot) study.

    Science.gov (United States)

    Müller, Axel; Goette, Andreas; Perings, Christian; Nägele, Herbert; Konorza, Thomas; Spitzer, Wilhelm; Schulz, Sabine-Susan; von Bary, Christian; Hoffmann, Matthias; Albani, Marco; Sack, Stefan; Niederlöhner, Annegret; Lewalter, Thorsten

    2013-06-01

    Implantable cardioverter-defibrillators (ICDs) alone or combined with cardiac resynchronization therapy (CRT-Ds) featuring automatic home monitoring (HM) function can be monitored remotely on a daily basis. Different ways of implementing HM into clinical routines are possible, with efficient patient management being the main objective. In this study, a concept using a telemedical service center (TmSC) to manage HM data was developed and investigated regarding patients' satisfaction, physicians' satisfaction, and alert filtering. Fifty-five ICD or CRT-D patients with symptomatic heart failure were enrolled. The TmSC received HM data, identified "actionable parameters" (APs) by following protocol-defined procedures, conducted structured patient interviews, and forwarded selected APs to the respective follow-up clinic. Satisfaction of patients and physicians with the TmSC was evaluated at the end of the study by purpose-designed questionnaires. During a mean follow-up of 402±200 days, 3,831 APs were identified and analyzed at the TmSC (5.28 per patient-month). Most APs were triggered by a pilot detection algorithm for worsening heart failure (2.80 per patient-month), followed by atrial tachyarrhythmia episodes (1.10 per patient-month) and ventricular pacing issues (0.87 per patient-month). The TmSC forwarded 682 APs (18% of all APs) to 10 study sites. Approximately 65% of physicians and patients deemed the TmSC improved patient care. The TmSC-based management concept was well accepted and appreciated by the majority of physicians and patients. It may be helpful in gaining symptomatic information on top of automatic HM data and in supporting smaller clinics in the follow-up of their device patients.

  13. CARDIAC FUNCTION AND IRON CHELATION IN THALASSEMIA MAJOR AND INTERMEDIA: A REVIEW OF THE UNDERLYING PATHOPHYSIOLOGY AND APPROACH TO CHELATION MANAGEMENT

    Directory of Open Access Journals (Sweden)

    Athanasios Aessopos

    2009-07-01

    Full Text Available Heart disease is the leading cause of mortality and one of the main causes of morbidity in beta-thalassemia. Patients with homozygous thalassemia may have either a severe phenotype which is usually transfusion dependent or a milder form that is thalassemia intermedia.  The two main factors that determine cardiac disease in homozygous β thalassemia are the high output state that results from chronic tissue hypoxia, hypoxia-induced compensatory reactions and iron overload.  The high output state playing a major role in thalassaemia intermedia and the iron load being more significant in the major form. Arrhythmias, vascular involvement that leads to an increased pulmonary vascular resistance and an increased systemic vascular stiffness and valvular abnormalities also contribute to the cardiac dysfunction in varying degrees according to the severity of the phenotype.  Endocrine abnormalities, infections, renal function and medications can also play a role in the overall cardiac function.  For thalassaemia major, regular and adequate blood transfusions and iron chelation therapy are the mainstays of management. The approach to thalassaemia intermedia, today, is aimed at monitoring for complications and initiating, timely, regular transfusions and/or iron chelation therapy.  Once the patients are on transfusions, then they should be managed in the same way as the thalassaemia major patients.  If cardiac manifestations of dysfunction are present in either form of thalassaemia, high pre transfusion Hb levels need to be maintained in order to reduce cardiac output and appropriate intensive chelation therapy needs to be instituted.  In general recommendations on chelation, today, are usually made according to the Cardiac Magnetic Resonance findings, if available.  With the advances in the latter technology and the ability to tailor chelation therapy according to the MRI findings as well as the availability of three iron chelators, together with

  14. Physiologic stress interventions in cardiac imaging

    International Nuclear Information System (INIS)

    Buda, A.J.

    1985-01-01

    Physiologic stress interventions are designed to assess the reserve capability of coronary flow and myocardial function. In the normal individual, a sufficiently intense physiologic stress may increase coronary flow and cardiac output by 500% to 600%. However, in patients with cardiac disease, these reserve responses may be absent, or considerably blunted. Thus, physiologic stress testing has proved extremely helpful in detecting cardiac abnormalities when resting cardiac function appears normal. Although dynamic exercise remains the standard approach to physiologic stress testing, a number of other interventions have been used, including: (1) isometric exercise, (2) atrial pacing, (3) cold pressor testing, (4) postextrasystolic potentiation, (5) volume loading, and (6) negative intrathoracic pressure. Each of these may be considered an alternative physiologic intervention whenever dynamic exercise is not feasible. These alternative approaches are important since, in our experience, 20% to 30% of subjects are unable to perform dynamic exercise, or exercise inadequately to produce a sufficiently intense cardiac stress. This chapter reviews physiologic considerations, indications, contraindications, protocols, and results of these physiologic stress interventions when used in combination with cardiac radionuclide procedures

  15. Changes in cardiac physiology after severe burn injury.

    Science.gov (United States)

    Williams, Felicia N; Herndon, David N; Suman, Oscar E; Lee, Jong O; Norbury, William B; Branski, Ludwik K; Mlcak, Ronald P; Jeschke, Marc G

    2011-01-01

    Cardiac stress, mediated by increased catecholamines, is the hallmark of severe burn injury typified by marked tachycardia, increased myocardial oxygen consumption, and increased cardiac output (CO). It remains one of the main determinants of survival in large burns. Currently, it is unknown for how long cardiac stress persists after a severe injury. Therefore, the aim of this study was to determine the extent and duration of cardiac stress after a severe burn. To determine persistence of cardiac alteration, the authors determined cardiac parameters of all surviving patients with burns ≥ 40% TBSA from 1998 to 2008. One hundred ninety-four patients were included in this study. Heart rate, mean arterial pressure, CO, stroke volume, cardiac index, and ejection fractions were measured at regular intervals from admission up to 2 years after injury. Rate pressure product was calculated as a correlate of myocardial oxygen consumption. All values were compared with normal nonburned children to validate the findings. Statistical analysis was performed using log transformed analysis of variance with Bonferroni correction and Student's t-test, where applicable. Heart rate, CO, cardiac index, and rate pressure product remained significantly increased in burned children for up to 2 years when compared with normal ranges (P < .05), indicating vastly increased cardiac stress. Ejection fraction was within normal limits for 2 years. Cardiac stress persists for at least 2 years postburn, and the authors suggest that attenuation of these detrimental responses may improve long-term morbidity.

  16. UFO - The Universal FEYNRULES Output

    Science.gov (United States)

    Degrande, Céline; Duhr, Claude; Fuks, Benjamin; Grellscheid, David; Mattelaer, Olivier; Reiter, Thomas

    2012-06-01

    We present a new model format for automatized matrix-element generators, the so-called Universal FEYNRULES Output (UFO). The format is universal in the sense that it features compatibility with more than one single generator and is designed to be flexible, modular and agnostic of any assumption such as the number of particles or the color and Lorentz structures appearing in the interaction vertices. Unlike other model formats where text files need to be parsed, the information on the model is encoded into a PYTHON module that can easily be linked to other computer codes. We then describe an interface for the MATHEMATICA package FEYNRULES that allows for an automatic output of models in the UFO format.

  17. Correction method for in-air output ratio for output variations occurring with changes in backscattered radiation

    Energy Technology Data Exchange (ETDEWEB)

    Tajiri, Minoru; Tokiya, Yuji; Watanabe, Kazuhiro [Research Center Hospital for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1, Anagawa, Inage-ku, Chiba 263-8555 (Japan); International University of Health and Welfare, 1-4-3, Mita, Minato-ku, Tokyo 108-8329 (Japan); Research Center Hospital for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1, Anagawa, Inage-ku, Chiba 263-8555 (Japan)

    2012-02-15

    Purpose: The in-air output ratio (S{sub c}) for a rectangular field is usually obtained using an equivalent square field formula. However, it is well-known that S{sub c} obtained using an equivalent square field formula differs slightly from the measured S{sub c}. Though several correction methods have been suggested for the monitor-backscatter effect, the authors propose a more simple correction method for a rectangular field. Methods: For rectangular fields and equivalent square fields, the authors assumed that the output variation was the product of six output variations for each backscattering area at the top of the collimator jaws, and the correction factor was the ratio of the output variation for a rectangular field to the output variation for an equivalent square field. The output variation was measured by using a telescope measurement. Results: The differences between the measured and corrected S{sub c} ranged from -0.20% to 0.28% for symmetric rectangular fields by applying the correction factor to S{sub c} obtained using an equivalent square field formula. This correction method is also available for asymmetric rectangular fields. Conclusions: The authors propose a method to correct S{sub c} obtained using an equivalent square field formula, and a method to obtain the output variation for a field defined by collimator jaws.

  18. Minimal output sets for identifiability.

    Science.gov (United States)

    Anguelova, Milena; Karlsson, Johan; Jirstrand, Mats

    2012-09-01

    Ordinary differential equation models in biology often contain a large number of parameters that must be determined from measurements by parameter estimation. For a parameter estimation procedure to be successful, there must be a unique set of parameters that can have produced the measured data. This is not the case if a model is not uniquely structurally identifiable with the given set of outputs selected as measurements. In designing an experiment for the purpose of parameter estimation, given a set of feasible but resource-consuming measurements, it is useful to know which ones must be included in order to obtain an identifiable system, or whether the system is unidentifiable from the feasible measurement set. We have developed an algorithm that, from a user-provided set of variables and parameters or functions of them assumed to be measurable or known, determines all subsets that when used as outputs give a locally structurally identifiable system and are such that any output set for which the system is structurally identifiable must contain at least one of the calculated subsets. The algorithm has been implemented in Mathematica and shown to be feasible and efficient. We have successfully applied it in the analysis of large signalling pathway models from the literature. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Cardiac Hemosiderosis in Transfusion DependentThalassemia: A Mini-Review

    Directory of Open Access Journals (Sweden)

    Ali Bazi

    2017-03-01

    Full Text Available Iron toxicity within cardiomyocytes is considered as the main pathogenesis of cardiac dysfunction in transfusion dependent thalassemia (TDT. Various methods such as measuring serum ferritin, evaluating cardiac functional and structural parameters by either cardiac magnetic resonance imaging (CMRI or echocardiography, and monitoring the heart rate variability (HRV have been proposed to monitor cardiac iron content in patients. High inconsistency is present regarding predictability of various parameters derived by each of these methods in order to predict the cardiac iron overload. The aim of present review was to grasp the most appropriate parameters predicting cardiac hemosiderosis in TDT. Predicating values for cardiac iron deposition of the most in-use indicators such as ferritin, cardiac T2* relaxation time, left ventricular ejection fraction (LVEF, and HRV were discussed. In addition, a description on the most effective preventive measures for cardiac hemosiderosis was provided.

  20. Comparative Cardiac Effects of Chlorproguanil/Dapsone and ...

    African Journals Online (AJOL)

    Cardiac toxicity has been reported with a number of antimalarial drugs. In this study we compared the cardiac effects of chlorproguanil/dapsone (CD) a new antimalarial drug, with that of chloroquine (CQ) during treatment of acute uncomplicated malaria in Nigeria. We monitored 62children with symptomatic malaria over 14 ...

  1. Pattern of Perioperative Cardiac Arrests at University of Maiduguri ...

    African Journals Online (AJOL)

    only 4 out of the 14 cardiac arrests. Only 2(14%) out of 14 cardiac arrests recovered to home discharge, one of them with significant neurological deficit. Majority of arrests were due to hypoxia from airway problems that were not detected early. There is need to improve on patient monitoring, knowledge of CPR and intensive ...

  2. Cardiac sodium channelopathies

    NARCIS (Netherlands)

    Amin, A.S.; Asghari-Roodsari, A.; Tan, H.L.

    2010-01-01

    Cardiac sodium channel are protein complexes that are expressed in the sarcolemma of cardiomyocytes to carry a large inward depolarizing current (I-Na) during phase 0 of the cardiac action potential. The importance of I-Na for normal cardiac electrical activity is reflected by the high incidence of

  3. Comparação dos efeitos da dobutamina e da milrinona sobre a hemodinâmica e o transporte de oxigênio em pacientes submetidos à cirurgia cardíaca com baixo débito cardíaco após indução anestésica Comparación de los efectos de la dobutamina y de la milrinona sobre la hemodinámica y el transporte de oxígeno en pacientes sometidos a cirugía cardiaca con bajo débito cardiaco después de inducción anestésica Comparison of the effects of dobutamine and milrinone on hemodynamic parameters and oxygen supply in patients undergoing cardiac surgery with low cardiac output after anesthetic induction

    Directory of Open Access Journals (Sweden)

    Maria José Carvalho Carmona

    2010-06-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: Diversas classes de fármacos inotrópicos, com efeitos hemodinâmicos diferentes, são utilizadas no tratamento do baixo débito cardíaco em pacientes com disfunção sistólica submetidos a procedimento cirúrgico cardíaco. O objetivo deste estudo foi comparar o efeito da dobutamina e da milrinona sobre a hemodinâmica e o transporte de oxigênio nessa população de pacientes. MÉTODO: Após aprovação do Comitê de Ética institucional e obtenção do consentimento escrito pós-informado, 20 pacientes submetidos à cirurgia cardíaca e com índice cardíaco JUSTIFICATIVA Y OBJETIVOS: Diversas clases de fármacos inotrópicos con efectos hemodinámicos diferentes, se usan en el tratamiento del bajo débito cardíaco en pacientes con disfunción sistólica sometidos al procedimiento quirúrgico cardíaco. El objetivo de este estudio, fue comparar el efecto de la dobutamina y de la milrinona sobre la hemodinámica y el transporte de oxígeno en esa población de pacientes. MÉTODO: Después de la aprobación del Comité de Ética institucional y de la obtención del consentimiento informado, 20 pacientes sometidos a la cirugía cardíaca y con índice cardíaco BACKGROUND AND OBJECTIVES: Several classes of inotropic drugs with different hemodynamic effects are used in the treatment of low cardiac output in patients with diastolic dysfunction undergoing cardiac surgery. The objective of the present study was to compare the effects of dobutamine and milrinone on hemodynamic parameters and oxygen supply in this population of patients. METHODS: After approval by the Ethics Committee of the institution and signing of the informed consent, 20 patients undergoing cardiac surgery with cardiac index < 2 L.min-1.m2 after anesthetic induction and place ment of a pulmonary artery catheter were randomly divided to receive dobutamine 5 µg.kg-1. min-1 (n = 10, or milrinone 0.5 µg.kg-1.min-1 (n = 10. Hemodynamic parameters were

  4. DOOp: DAOSPEC Output Optimizer pipeline

    Science.gov (United States)

    Cantat-Gaudin, Tristan; Donati, Paolo; Pancino, Elena; Bragaglia, Angela; Vallenari, Antonella; Friel, Eileen D.; Sordo, Rosanna; Jacobson, Heather R.; Magrini, Laura

    2017-09-01

    The DAOSPEC Output Optimizer pipeline (DOOp) runs efficient and convenient equivalent widths measurements in batches of hundreds of spectra. It uses a series of BASH scripts to work as a wrapper for the FORTRAN code DAOSPEC (ascl:1011.002) and uses IRAF (ascl:9911.002) to automatically fix some of the parameters that are usually set by hand when using DAOSPEC. This allows batch-processing of quantities of spectra that would be impossible to deal with by hand. DOOp was originally built for the large quantity of UVES and GIRAFFE spectra produced by the Gaia-ESO Survey, but just like DAOSPEC, it can be used on any high resolution and high signal-to-noise ratio spectrum binned on a linear wavelength scale.

  5. The 2008 Financial Crisis and Potential Output in Asia : Impact and Policy Implications

    OpenAIRE

    Cyn-Young Park; Ruperto P. Majuca; Josef T. Yap

    2010-01-01

    Monitoring the behavior of potential output helps policymakers implement appropriate policies in response to an economic crisis. In the short-run, estimates of the output gap can guide the timing of the implementation and withdrawal of stimulus measures. In the medium- to long-term, these estimates can also provide the basis for gauging productive potential and, hence, guide policies to support sustainable, non-inflationary output growth. In this paper, we investigate the post-crisis behavior...

  6. Legal Aspects of Cardiac Rehabilitation Exercise Programs.

    Science.gov (United States)

    Herbert, William; Herbert, David L.

    1988-01-01

    A medical model is used to examine liability issues related to cardiac rehabilitation programs. Obtaining effective informed consent from patients, standardizing policies and procedures, and exercise prescription and monitoring are among the proposed elements of a risk management model for developing safe and legally defensible programs. (IAH)

  7. Probabilistic Output Analysis by Program Manipulation

    DEFF Research Database (Denmark)

    Rosendahl, Mads; Kirkeby, Maja Hanne

    2015-01-01

    The aim of a probabilistic output analysis is to derive a probability distribution of possible output values for a program from a probability distribution of its input. We present a method for performing static output analysis, based on program transformation techniques. It generates a probabilit...

  8. Takotsubo cardiomyopathy in myasthaenia gravis crisis confirmed by cardiac MRI.

    Science.gov (United States)

    Harries, I B; Levoir, H; Bucciarelli-Ducci, C; Ramcharitar, S

    2015-09-28

    Myasthaenia gravis crisis and Takotsubo cardiomyopathy are rare conditions that can be precipitated by emotional or physical stress. Myasthaenia gravis has a variety of cardiac manifestations but Takotsubo cardiomyopathy, particularly in male patients, has rarely been reported. We describe a unique case of a 70-year-old man who developed Takotsubo cardiomyopathy during his first presentation with a myasthaenia gravis crisis. He had not received plasmapharesis or immunoglobulin therapy. Striking ECG traces and cardiac MRI helped to confirm the diagnosis. Cardiac manifestations of myasthaenia gravis and myasthaenia gravis itself have overlapping symptoms; the importance of cardiac monitoring and clinical vigilance in such cases is discussed. The utility of cardiac MRI in assessing cardiac manifestations of myasthaenia gravis is also highlighted. 2015 BMJ Publishing Group Ltd.

  9. Stimulating endogenous cardiac regeneration

    Directory of Open Access Journals (Sweden)

    Amanda eFinan

    2015-09-01

    Full Text Available The healthy adult heart has a low turnover of cardiac myocytes. The renewal capacity, however, is augmented after cardiac injury. Participants in cardiac regeneration include cardiac myocytes themselves, cardiac progenitor cells, and peripheral stem cells, particularly from the bone marrow compartment. Cardiac progenitor cells and bone marrow stem cells are augmented after cardiac injury, migrate to the myocardium, and support regeneration. Depletion studies of these populations have demonstrated their necessary role in cardiac repair. However, the potential of these cells to completely regenerate the heart is limited. Efforts are now being focused on ways to augment these natural pathways to improve cardiac healing, primarily after ischemic injury but in other cardiac pathologies as well. Cell and gene therapy or pharmacological interventions are proposed mechanisms. Cell therapy has demonstrated modest results and has passed into clinical trials. However, the beneficial effects of cell therapy have primarily been their ability to produce paracrine effects on the cardiac tissue and recruit endogenous stem cell populations as opposed to direct cardiac regeneration. Gene therapy efforts have focused on prolonging or reactivating natural signaling pathways. Positive results have been demonstrated to activate the endogenous stem cell populations and are currently being tested in clinical trials. A potential new avenue may be to refine pharmacological treatments that are currently in place in the clinic. Evidence is mounting that drugs such as statins or beta blockers may alter endogenous stem cell activity. Understanding the effects of these drugs on stem cell repair while keeping in mind their primary function may strike a balance in myocardial healing. To maximize endogenous cardiac regeneration,a combination of these approaches couldameliorate the overall repair process to incorporate the participation ofmultiple cell players.

  10. Optical transducers with frequency output

    Science.gov (United States)

    Osadchuk, Oleksandr V.; Osadchuk, Volodymyr S.; Osadchuk, Iaroslav O.; Kolimoldayev, Maksat; Komada, Paweł; Mussabekov, Kanat

    2017-08-01

    In this work the characteristics research of microelectronic transducers of optical radiation with a frequency output signal on the basis of a hybrid integrated circuit consisting of a bipolar and a field-effect transistor with a Schottky barrier is presented. The connection of an external inductance to electrodes a collector - drain allows to implement the auto generating device. The frequency of the device generation depends on power of optical radiation falling on photosensing elements as a photoresistor, photodiode and photosensing transistors switched on in a circuit of the self-excited oscillator. The impedance on electrodes the collector - drain of bipolar and field transistors has capacitive reactive part and negative active resistance, which compensates power losses in a tuning circuit of the device. On the base of a nonlinear equivalent circuit of the transducer on an alternating current the analytical expressions of function of transformation and equation of sensitivity are obtained. The sensitivity of optical transducers lays in a range from 25 kHz/μWt/cm2 up to 150 kHz/μWt/cm2.

  11. Model output: fact or artefact?

    Science.gov (United States)

    Melsen, Lieke

    2015-04-01

    As a third-year PhD-student, I relatively recently entered the wonderful world of scientific Hydrology. A science that has many pillars that directly impact society, for example with the prediction of hydrological extremes (both floods and drought), climate change, applications in agriculture, nature conservation, drinking water supply, etcetera. Despite its demonstrable societal relevance, hydrology is often seen as a science between two stools. Like Klemeš (1986) stated: "By their academic background, hydrologists are foresters, geographers, electrical engineers, geologists, system analysts, physicists, mathematicians, botanists, and most often civil engineers." Sometimes it seems that the engineering genes are still present in current hydrological sciences, and this results in pragmatic rather than scientific approaches for some of the current problems and challenges we have in hydrology. Here, I refer to the uncertainty in hydrological modelling that is often neglected. For over thirty years, uncertainty in hydrological models has been extensively discussed and studied. But it is not difficult to find peer-reviewed articles in which it is implicitly assumed that model simulations represent the truth rather than a conceptualization of reality. For instance in trend studies, where data is extrapolated 100 years ahead. Of course one can use different forcing datasets to estimate the uncertainty of the input data, but how to prevent that the output is not a model artefact, caused by the model structure? Or how about impact studies, e.g. of a dam impacting river flow. Measurements are often available for the period after dam construction, so models are used to simulate river flow before dam construction. Both are compared in order to qualify the effect of the dam. But on what basis can we tell that the model tells us the truth? Model validation is common nowadays, but validation only (comparing observations with model output) is not sufficient to assume that a

  12. Anaesthetic management of a rare variety of cardiac myxoma for ...

    African Journals Online (AJOL)

    Primary cardiac tumours are rare. Right ventricular myxomas and a combination of right atrial and ventricular myxomas are very rare. A patient with myxoma has several problems, including haemodynamic compromise in a particular position, embolisation and hypoxaemia because of low output and possible shunts.

  13. Consumer sleep monitors: is there a baby in the bathwater?

    Directory of Open Access Journals (Sweden)

    Russo K

    2015-11-01

    Full Text Available Kathryn Russo,1 Balaji Goparaju,1 Matt T Bianchi1,2 1Department of Neurology, Massachusetts General Hospital, 2Division of Sleep Medicine, Harvard Medical School, Boston, MA, USA Abstract: The rapid expansion of consumer sleep devices is outpacing the validation data necessary to assess the potential use of these devices in clinical and research settings. Common sleep monitoring devices utilize a variety of sensors to track movement as well as cardiac and respiratory physiology. The variety of sensors and user-specific factors offer the potential, at least theoretically, for clinically relevant information. We describe the current challenges for interpretation of consumer sleep monitoring data, since the devices are mainly used in nonmedical contexts (consumer use although medically-definable sleep disorders may commonly occur in this setting. A framework for addressing questions of how certain devices might be useful is offered. We suggest that multistage validation efforts are crucially needed, from the level of sensor data and algorithm output, to extrapolations beyond healthy adults and into other populations and real-world environments. Keywords: movement, cardiac and respiratory physiology, sensor, consumer sleep monitoring data

  14. Interferometric output coupling of ring optical oscillators.

    Science.gov (United States)

    Chaitanya Kumar, S; Esteban-Martin, A; Ebrahim-Zadeh, M

    2011-04-01

    We demonstrate the successful deployment of an antiresonant ring (ARR) interferometer within a ring optical resonator and its use for absolute optimization of output power. The integration of the ARR interferometer in a folded arm of the ring oscillator provides continuously variable output coupling over broad spectral range and under any operating conditions. We demonstrate the technique using a picosecond optical parametric oscillator (OPO), where we show continuously adjustable output coupling and optimization of the output power for different pump power conditions, from 3.5 W to 13.5 W. By operating the OPO under an optimized output coupling at 14 W of pump power, we obtain >5 W of extracted signal power, more than 2.6 times that with a ~5% conventional output coupler. We also show that the inclusion of the ARR interferometer has no detrimental effect on the spatial, temporal, and spectral characteristics of OPO output.

  15. Cardiac sodium channelopathies.

    Science.gov (United States)

    Amin, Ahmad S; Asghari-Roodsari, Alaleh; Tan, Hanno L

    2010-07-01

    Cardiac sodium channel are protein complexes that are expressed in the sarcolemma of cardiomyocytes to carry a large inward depolarizing current (INa) during phase 0 of the cardiac action potential. The importance of INa for normal cardiac electrical activity is reflected by the high incidence of arrhythmias in cardiac sodium channelopathies, i.e., arrhythmogenic diseases in patients with mutations in SCN5A, the gene responsible for the pore-forming ion-conducting alpha-subunit, or in genes that encode the ancillary beta-subunits or regulatory proteins of the cardiac sodium channel. While clinical and genetic studies have laid the foundation for our understanding of cardiac sodium channelopathies by establishing links between arrhythmogenic diseases and mutations in genes that encode various subunits of the cardiac sodium channel, biophysical studies (particularly in heterologous expression systems and transgenic mouse models) have provided insights into the mechanisms by which INa dysfunction causes disease in such channelopathies. It is now recognized that mutations that increase INa delay cardiac repolarization, prolong action potential duration, and cause long QT syndrome, while mutations that reduce INa decrease cardiac excitability, reduce electrical conduction velocity, and induce Brugada syndrome, progressive cardiac conduction disease, sick sinus syndrome, or combinations thereof. Recently, mutation-induced INa dysfunction was also linked to dilated cardiomyopathy, atrial fibrillation, and sudden infant death syndrome. This review describes the structure and function of the cardiac sodium channel and its various subunits, summarizes major cardiac sodium channelopathies and the current knowledge concerning their genetic background and underlying molecular mechanisms, and discusses recent advances in the discovery of mutation-specific therapies in the management of these channelopathies.

  16. Hyperplastic Cardiac Sarcoma Recurrence

    Directory of Open Access Journals (Sweden)

    Masood A. Shariff

    2015-01-01

    Full Text Available Primary cardiac sarcomas are rare tumors with a median survival of 6–12 months. Data suggest that an aggressive multidisciplinary approach may improve patient outcome. We present the case of a male who underwent resection of cardiac sarcoma three times from the age of 32 to 34. This report discusses the malignant nature of cardiac sarcoma and the importance of postoperative multidisciplinary care.

  17. Improving health professionals' self-efficacy to support cardiac patients' emotional recovery: the 'Cardiac Blues Project'.

    Science.gov (United States)

    Murphy, Barbara M; Higgins, Rosemary O; Shand, Lyndel; Page, Karen; Holloway, Elizabeth; Le Grande, Michael R; Jackson, Alun C

    2017-02-01

    Many patients experience the 'cardiac blues' at the time of an acute cardiac event, and one in five go on to develop severe depression. These emotional responses often go undetected and unacknowledged. We initiated the 'Cardiac Blues Project' in order to help support patients' emotional recovery. As part of the project, we developed online training in order to support health professionals in the identification and management of the cardiac blues and depression. The aim of this study was to assess the acceptability of the training and its impacts on health professionals' self-efficacy. In July 2014, a 'cardiac blues' pack of patient resources, including access to health professional online training, was mailed to 606 centres across Australia. In the first 3 months after distribution, 140 health professionals registered to undertake the online training and participated in the present study. Participants provided information via a six-item pre- and post-training self-efficacy scale and on 10 post-training acceptability items. Health professionals' self-efficacy improved significantly after undertaking the online training across the six domains assessed and for the total score. Acceptability of the training was high across all 10 items assessed. Ratings of usefulness of the training in clinical practice were particularly favourable amongst those who worked directly with cardiac patients. The health professional training significantly improves health professionals' confidence in identifying and managing the 'cardiac blues' and depression. Monitoring of uptake is ongoing and future studies will investigate patient outcomes.

  18. Reactor power distribution monitor

    International Nuclear Information System (INIS)

    Hoizumi, Atsushi.

    1986-01-01

    Purpose: To grasp the margin for the limit value of the power distribution peaking factor inside the reactor under operation by using the reactor power distribution monitor. Constitution: The monitor is composed of the 'constant' file, (to store in-reactor power distributions obtained from analysis), TIP and thermocouple, lateral output distribution calibrating apparatus, axial output distribution synthesizer and peaking factor synthesizer. The lateral output distribution calibrating apparatus is used to make calibration by comparing the power distribution obtained from the thermocouples to the power distribution obtained from the TIP, and then to provide the power distribution lateral peaking factors. The axial output distribution synthesizer provides the power distribution axial peaking factors in accordance with the signals from the out-pile neutron flux detector. These axial and lateral power peaking factors are synthesized with high precision in the three-dimensional format and can be monitored at any time. (Kamimura, M.)

  19. Giant cardiac myxoma.

    Science.gov (United States)

    Barlis, Peter; Lim, Eu Jin; Gow, Paul J; Seevanayagam, Siven; Calafiore, Paul; Chan, Robert K

    2007-10-01

    Although cardiac myxomas remain an uncommon group of malignancies, they are the most common form of primary cardiac tumour. Clinical presentations can be varied with local cardiac haemodynamic consequences, valvular insufficiency or even embolic phenomena. We present a case of a 46-year-old man with chronic abdominal pain and discuss a number of diagnostic challenges that were confronted up until a definitive diagnosis of cardiac myxoma was made. The resultant outcome was excellent with the patient achieving complete recovery from long term disabling symptoms.

  20. Cardiac surgery in the parturient.

    Science.gov (United States)

    Chandrasekhar, Shobana; Cook, Christopher R; Collard, Charles D

    2009-03-01

    Heart disease is the primary cause of nonobstetric mortality in pregnancy, occurring in 1%-3% of pregnancies and accounting for 10%-15% of maternal deaths. Congenital heart disease has become more prevalent in women of childbearing age, representing an increasing percentage (up to 75%) of heart disease in pregnancy. Untreated maternal heart disease also places the fetus at risk. Independent predictors of neonatal complications include a maternal New York Heart Association heart failure classification >2, anticoagulation use during pregnancy, smoking, multiple gestation, and left heart obstruction. Because cardiac surgical morbidity and mortality in the parturient is higher than nonpregnant patients, most parturients with cardiac disease are first managed medically, with cardiac surgery being reserved when medical management fails. Risk factors for maternal mortality during cardiac surgery include the use of vasoactive drugs, age, type of surgery, reoperation, and maternal functional class. Risk factors for fetal mortality include maternal age >35 yr, functional class, reoperation, emergency surgery, type of myocardial protection, and anoxic time. Nonetheless, acceptable maternal and fetal perioperative mortality rates may be achieved through such measures as early preoperative detection of maternal cardiovascular decompensation, use of fetal monitoring, delivery of a viable fetus before the operation and scheduling surgery on an elective basis during the second trimester. Additionally, fetal morbidity may be reduced during cardiopulmonary bypass by optimizing maternal oxygen-carrying capacity and uterine blood flow. Current maternal bypass recommendations include: 1) maintaining the pump flow rate >2.5 L x min(-1) x m(-2) and perfusion pressure >70 mm Hg; 2) maintaining the hematocrit > 28%; 3) using normothermic perfusion when feasible; 4) using pulsatile flow; and 5) using alpha-stat pH management.

  1. Early goal-directed therapy in moderate to high-risk cardiac surgery patients

    Directory of Open Access Journals (Sweden)

    Kapoor Poonam

    2008-01-01

    Full Text Available Early goal-directed therapy is a term used to describe the guidance of intravenous fluid and vasopressor/inotropic therapy by using cardiac output or similar parameters in the immediate post-cardiopulmonary bypass in cardiac surgery patients. Early recognition and therapy during this period may result in better outcome. In keeping with this aim in the cardiac surgery patients, we conducted the present study. The study included 30 patients of both sexes, with EuroSCORE ≥3 undergoing coronary artery bypass surgery under cardiopulmonary bypass. The patients were randomly divided into two groups, namely, control and early goal-directed therapy (EGDT groups. All the subjects received standardized care; arterial pressure was monitored through radial artery, central venous pressure through a triple lumen in the right internal jugular vein, electrocardiogram, oxygen saturation, temperature, urine output per hour and frequent arterial blood gas analysis. In addition, cardiac index monitoring using FloTrac™ and continuous central venous oxygen saturation using PreSep™ was used in patients in the EGTD group. Our aim was to maintain the cardiac index at 2.5-4.2 l/min/m 2 , stroke volume index 30-65 ml/beat/m 2 , systemic vascular resistance index 1500-2500 dynes/s/cm 5 /m 2 , oxygen delivery index 450-600 ml/min/m 2 , continuous central venous oximetry more than 70%, stroke volume variation less than 10%; in addition to the control group parameters such as central venous pressure 6-8 mmHg, mean arterial pressure 90-105 mmHg, normal arterial blood gas analysis values, pulse oximetry, hematocrit value above 30% and urine output more than 1 ml/kg/h. The aims were achieved by altering the administration of intravenous fluids and doses of inotropic or vasodilator agents. Three patients were excluded from the study and the data of 27 patients analyzed. The extra volume used (330 ± 160 v/s 80 ± 80 ml, P = 0.043 number of adjustments of inotropic agents (3

  2. Update on arrhythmias and cardiac pacing 2013.

    Science.gov (United States)

    Almendral, Jesús; Pombo, Marta; Martínez-Alday, Jesús; González-Rebollo, José M; Rodríguez-Font, Enrique; Martínez-Ferrer, José; Castellanos, Eduardo; García-Fernández, F Javier; Ruiz-Mateas, Francisco

    2014-04-01

    This report discusses a selection of the most relevant articles on cardiac arrhythmias and pacing published in 2013. The first section discusses arrhythmias, classified as regular paroxysmal supraventricular tachyarrhythmias, atrial fibrillation, and ventricular arrhythmias, together with their treatment by means of an implantable cardioverter defibrillator. The next section reviews cardiac pacing, subdivided into resynchronization therapy, remote monitoring of implantable devices, and pacemakers. The final section discusses syncope. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  3. The 'icon' of output efficiency

    International Nuclear Information System (INIS)

    Bligh, L.N.; Evans, S.G.; Larcos, G.; Gruenewald, S.M.

    1999-01-01

    Full text: Output efficiency (OE) is a well-validated parameter used in the assessment of hydronephrosis. Current analysis on Microdelta appears to produce few low OE values and occasional inability to produce a result. We sought an OE program which gave a reliable response over the full range of values. The aims of this study were to determine: (1) whether OE results are comparable between two computer systems; (2) a normal range for OE on an ICON; (3) inter-observer reproducibility; and (4) the correlation between the two programs and the residual cortical activity ratio (RCA), an index which assesses tracer washout from the 20 min cortical activity/peak cortical activity. Accordingly, two blinded medical radiation scientists reviewed 41 kidneys (26 native, 15 transplant) and calculated OE for each kidney on the ICON and Microdelta computers The OE on the Microdelta and the ICON had good correspondence (r = 0.6%, SEE = 6.2). The extrapolated normal range for ICON OE was 69-92% (mean 80.9%). The inter-observer reproducibility on the ICON was excellent with a CV of 8.7%. ICON OE and RCA had a strong correlation (r = - 0.77, SEE = 0.09), compared with a weaker correlation for the Microdelta (r = 0.47, SEE = 0.13). Processing on the ICON was almost half that of the Microdelta at 4 min compared with 7 min. We conclude that OE generated by these computer programs has good correlation, an established normal range, excellent interobserver reproducibility, but differing correlation with RCA. The response of the ICON program to low ranges of OE is being investigated further

  4. Relationship between peak cardiac pumping capability and indices of cardio-respiratory fitness in healthy individuals.

    Science.gov (United States)

    Jakovljevic, Djordje G; Popadic-Gacesa, Jelena Z; Barak, Otto F; Nunan, David; Donovan, Gay; Trenell, Michael I; Grujic, Nikola G; Brodie, David A

    2012-09-01

    Cardiac power output (CPO) is a unique and direct measure of overall cardiac function (i.e. cardiac pumping capability) that integrates both flow- and pressure-generating capacities of the heart. The present study assessed the relationship between peak exercise CPO and selected indices of cardio-respiratory fitness. Thirty-seven healthy adults (23 men and 14 women) performed an incremental exercise test to volitional fatigue using the Bruce protocol with gas exchange and ventilatory measurements. Following a 40-min recovery, the subjects performed a constant maximum workload exercise test at or above 95% of maximal oxygen consumption. Cardiac output was measured using the exponential CO(2) rebreathing method. The CPO, expressed in W, was calculated as the product of the mean arterial blood pressure and cardiac output. At peak exercise, CPO was well correlated with cardiac output (r = 0·92, Pcardio-respiratory fitness such as oxygen consumption, anaerobic threshold, oxygen pulse, minute ventilation, carbon dioxide production and heart rate should not be used as surrogates for overall cardiac function and pumping capability of the heart. © 2012 The Authors Clinical Physiology and Functional Imaging © 2012 Scandinavian Society of Clinical Physiology and Nuclear Medicine.

  5. LOAD THAT MAXIMIZES POWER OUTPUT IN COUNTERMOVEMENT JUMP

    Directory of Open Access Journals (Sweden)

    Pedro Jimenez-Reyes

    2016-02-01

    Full Text Available ABSTRACT Introduction: One of the main problems faced by strength and conditioning coaches is the issue of how to objectively quantify and monitor the actual training load undertaken by athletes in order to maximize performance. It is well known that performance of explosive sports activities is largely determined by mechanical power. Objective: This study analysed the height at which maximal power output is generated and the corresponding load with which is achieved in a group of male-trained track and field athletes in the test of countermovement jump (CMJ with extra loads (CMJEL. Methods: Fifty national level male athletes in sprinting and jumping performed a CMJ test with increasing loads up to a height of 16 cm. The relative load that maximized the mechanical power output (Pmax was determined using a force platform and lineal encoder synchronization and estimating the power by peak power, average power and flight time in CMJ. Results: The load at which the power output no longer existed was at a height of 19.9 ± 2.35, referring to a 99.1 ± 1% of the maximum power output. The load that maximizes power output in all cases has been the load with which an athlete jump a height of approximately 20 cm. Conclusion: These results highlight the importance of considering the height achieved in CMJ with extra load instead of power because maximum power is always attained with the same height. We advise for the preferential use of the height achieved in CMJEL test, since it seems to be a valid indicative of an individual's actual neuromuscular potential providing a valid information for coaches and trainers when assessing the performance status of our athletes and to quantify and monitor training loads, measuring only the height of the jump in the exercise of CMJEL.

  6. Frequency of Cardiac Arrhythmias in Patients with Aluminum Phosphide Poisoning

    Directory of Open Access Journals (Sweden)

    Umair Aziz

    2015-12-01

    Full Text Available Background: Cardiac failure is the major lethal consequence of aluminum phosphide (AlP poisoning. This study was designed to determine the frequency of cardiac arrhythmias in patients with AlP poisoning. Methods: In this prospective cross-sectional study, patients with definitive history of AlP poisoning treated at emergency department of Allied Hospital Faisalabad, Faisalabad, Pakistan, from July 2013 to November 2014 were included. On admission, twelve-lead electrocardiogram (ECG was performed for all patients. During admission, all patients underwent continuous cardiac monitoring using a cardiac monitor. If an arrhythmia was suspected on the cardiac monitor, another ECG was obtained immediately.  Results: During the study period, 100 patients with AlP poisoning (63% men were treated at Allied Hospital Faisalabad. Mean age of the patients was 26.7 ± 7.9 years ranging from 16 to 54 years. Tachycardia was detected in 68 patients and bradycardia in 12 patients. Hypotension was observed in 75 patients. Eighty patients developed cardiac arrhythmia. The most frequent arrhythmia was atrial fibrillation (31% of patients followed by ventricular fibrillation (20%, ventricular tachycardia (17%, 3rd degree AV block (7% and 2nd degree AV block (5%. In total, 78 patients died, depicting a 78% mortality rate following wheat pill poisoning. Among those who died, seventy-one patients had cardiac arrhythmia. Comparison of death rate between patients with and without cardiac arrhythmia showed a significant difference (71/80 (88.8% vs. 7/20 (35%; P < 0.001.  Conclusion: Wheat pill poisoning causes a very high mortality, and circulatory collapse is the major cause of death among these patients. Most of the patients with AlP poisoning develop cardiac arrhythmias which are invariably life threatening. Early detection of cardiac disorders and proper management of arrhythmias may reduce mortalities.

  7. Theoretical analysis of magnetic sensor output voltage

    International Nuclear Information System (INIS)

    Liu Haishun; Dun Chaochao; Dou Linming; Yang Weiming

    2011-01-01

    The output voltage is an important parameter to determine the stress state in magnetic stress measurement, the relationship between the output voltage and the difference in the principal stresses was investigated by a comprehensive application of magnetic circuit theory, magnetization theory, stress analysis as well as the law of electromagnetic induction, and a corresponding quantitative equation was derived. It is drawn that the output voltage is proportional to the difference in the principal stresses, and related to the angle between the principal stress and the direction of the sensor. This investigation provides a theoretical basis for the principle stresses measurement by output voltage. - Research highlights: → A comprehensive investigation of magnetic stress signal. → Derived a quantitative equation about output voltage and the principal stresses. → The output voltage is proportional to the difference of the principal stresses. → Provide a theoretical basis for the principle stresses measurement.

  8. Output order in immediate serial recall.

    Science.gov (United States)

    Tan, Lydia; Ward, Geoff

    2007-07-01

    In two experiments, we examined the effect of output order in immediate serial recall (ISR). In Experiment 1, three groups of participants saw lists of eight words and wrote down the words in the rows corresponding to their serial positions in an eight-row response grid. One group was precued to respond in forward order, a second group was precued to respond in any order, and a third group was postcued for response order. There were significant effects of output order, but not of cue type. Relative to the forward output order, the free output order led to enhanced recency and diminished primacy, with superior performance for words output early in recall. These results were replicated in Experiment 2 using six-item lists, which further suggests that output order plays an important role in the primacy effect in ISR and that the recency items are most highly accessible at recall.

  9. Cardiac Catheterization (For Kids)

    Science.gov (United States)

    ... First Aid & Safety Doctors & Hospitals Videos Recipes for Kids Kids site Sitio para niños How the Body Works ... Educators Search English Español Cardiac Catheterization KidsHealth / For Kids / Cardiac Catheterization What's in this article? What Is ...

  10. Cardiac image segmentation for contrast agent videodensitometry.

    Science.gov (United States)

    Mischi, Massimo; Kalker, Antonius A C M; Korsten, Hendrikus H M

    2005-02-01

    Indicator dilution techniques are widely used in the intensive care unit and operating room for cardiac parameter measurements. However, the invasiveness of current techniques represents a limitation for their clinical use. The development of stable ultrasound contrast agents allows new applications of the indicator dilution method. Ultrasound contrast agent dilutions permit an echographic noninvasive measurement of cardiac output, ejection fraction, and blood volumes. The indicator dilution curves are measured by videodensitometry of specific regions of interest and processed for the cardiac parameter assessment. Therefore, the major indicator dilution imaging issue is the detection of proper contrast videodensitometry regions that maximize the signal-to-noise ratio of the measured indicator dilution curves. This paper presents an automatic contour detection algorithm for indicator dilution videodensitometry. The algorithm consists of a radial filter combined with an outlier correction. It maximizes the region of interest by excluding cardiac structures that act as interference to the videodensitometric analysis. It is fast, projection independent, and allows the simultaneous detection of multiple contours in real time. The system is compared to manual contour definition on both echographic and magnetic resonance images.

  11. Does trade drive global output growth?

    OpenAIRE

    Leon Podkaminer

    2014-01-01

    Conventional econometric analysis suggests that there has been a longer-term relationship between nominal world output and nominal world exports. The analysis says something about the rules governing adjustments in world output and exports. It appears that GDP plays the first fiddle. Rising world output seems to have pushed up world exports. But rising world exports do not seem to have resulted in positive changes in global GDP. The global growth slowdown, observed since the early 1970s, may ...

  12. Mathematical cardiac electrophysiology

    CERN Document Server

    Colli Franzone, Piero; Scacchi, Simone

    2014-01-01

    This book covers the main mathematical and numerical models in computational electrocardiology, ranging from microscopic membrane models of cardiac ionic channels to macroscopic bidomain, monodomain, eikonal models and cardiac source representations. These advanced multiscale and nonlinear models describe the cardiac bioelectrical activity from the cell level to the body surface and are employed in both the direct and inverse problems of electrocardiology. The book also covers advanced numerical techniques needed to efficiently carry out large-scale cardiac simulations, including time and space discretizations, decoupling and operator splitting techniques, parallel finite element solvers. These techniques are employed in 3D cardiac simulations illustrating the excitation mechanisms, the anisotropic effects on excitation and repolarization wavefronts, the morphology of electrograms in normal and pathological tissue and some reentry phenomena. The overall aim of the book is to present rigorously the mathematica...

  13. Biomaterials for cardiac regeneration

    CERN Document Server

    Ruel, Marc

    2015-01-01

    This book offers readers a comprehensive biomaterials-based approach to achieving clinically successful, functionally integrated vasculogenesis and myogenesis in the heart. Coverage is multidisciplinary, including the role of extracellular matrices in cardiac development, whole-heart tissue engineering, imaging the mechanisms and effects of biomaterial-based cardiac regeneration, and autologous bioengineered heart valves. Bringing current knowledge together into a single volume, this book provides a compendium to students and new researchers in the field and constitutes a platform to allow for future developments and collaborative approaches in biomaterials-based regenerative medicine, even beyond cardiac applications. This book also: Provides a valuable overview of the engineering of biomaterials for cardiac regeneration, including coverage of combined biomaterials and stem cells, as well as extracellular matrices Presents readers with multidisciplinary coverage of biomaterials for cardiac repair, including ...

  14. Sudden cardiac death

    Directory of Open Access Journals (Sweden)

    Neeraj Parakh

    2015-01-01

    Full Text Available Sudden cardiac death is one of the most common cause of mortality worldwide. Despite significant advances in the medical science, there is little improvement in the sudden cardiac death related mortality. Coronary artery disease is the most common etiology behind sudden cardiac death, in the above 40 years population. Even in the apparently healthy population, there is a small percentage of patients dying from sudden cardiac death. Given the large denominator, this small percentage contributes to the largest burden of sudden cardiac death. Identification of this at risk group among the apparently healthy individual is a great challenge for the medical fraternity. This article looks into the causes and methods of preventing SCD and at some of the Indian data. Details of Brugada syndrome, Long QT syndrome, Genetics of SCD are discussed. Recent guidelines on many of these causes are summarised.

  15. Nursing Considerations in Pediatric Cardiac Critical Care.

    Science.gov (United States)

    Jones, Melissa B; Tucker, Dawn

    2016-08-01

    The objectives of this review are to describe the education and critical thinking skills that characterize pediatric critical care nursing and how these skills impact patient care and outcomes in pediatric cardiac critical care. MEDLINE and PubMed. Pediatric cardiac critical care nurses manage complex and vulnerable patients requiring various levels of support. Effective care of these patients requires knowledge about the complex anatomy and physiology associated with congenital and acquired heart disease, as well as the effects of mechanical ventilation, mechanical circulatory support, and vasoactive medications. Strong physical examination skills, accurate interpretation of hemodynamic and laboratory data, active participation in bedside rounds, excellent communication skills, meticulous care of invasive monitoring catheters and tubes, and compassionate support of families are among the skills that distinguish a cardiac critical care nurse.

  16. Exercise efficiency of low power output cycling.

    Science.gov (United States)

    Reger, M; Peterman, J E; Kram, R; Byrnes, W C

    2013-12-01

    Exercise efficiency at low power outputs, energetically comparable to daily living activities, can be influenced by homeostatic perturbations (e.g., weight gain/loss). However, an appropriate efficiency calculation for low power outputs used in these studies has not been determined. Fifteen active subjects (seven females, eight males) performed 14, 5-min cycling trials: two types of seated rest (cranks vertical and horizontal), passive (motor-driven) cycling, no-chain cycling, no-load cycling, cycling at low (10, 20, 30, 40 W), and moderate (50, 60, 80, 100, 120 W) power outputs. Mean delta efficiency was 57% for low power outputs compared to 41.3% for moderate power outputs. Means for gross (3.6%) and net (5.7%) efficiencies were low at the lowest power output. At low power outputs, delta and work efficiency values exceeded theoretical values. In conclusion, at low power outputs, none of the common exercise efficiency calculations gave values comparable to theoretical muscle efficiency. However, gross efficiency and the slope and intercept of the metabolic power vs mechanical power output regression provide insights that are still valuable when studying homeostatic perturbations. © 2012 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Output filters for AC adjustable speed drives

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Hanigovszki, Norbert; Landkildehus, Jorn, Jorn

    2007-01-01

    -phase applications the occurrence of common-mode (CM) voltage is inherent due to asymmetrical output pulses [1]. Consequently, several secondary effects arise at the inverter's output: high-frequency conducted and radiated emissions, leakage current, motor insulation stress due to wave reflection [2], bearing stress...... due to bearing currents, acoustic switching noise. Depending on the specific application, the mitigation of some of these effects (or all) might be necessary. The common solution for mitigating the secondary effects at the output of PWM-VSI is the use of output filters [3],[5],[6]. Several types...

  18. Dynamic NMR cardiac imaging in a piglet

    International Nuclear Information System (INIS)

    Doyle, M.; Rzedzian, R.; Mansfield, P.; Coupland, R.E.

    1983-01-01

    NMR echo-planar imaging (EPI) has been used in a real-time mode to visualise the thorax of a live piglet. Moving pictures are available on an immediate image display system which demonstrates dynamic cardiac function. Frame rates vary from one per cardiac cycle in a prospective stroboscopic mode with immediate visual output to a maximum of 10 frames per second yielding up to six looks in one piglet heart cycle, but using a visual playback mode. A completely new system has been used to obtain these images, features of which include a probe assembly with 22 cm access and an AP400 array processor for real-time data processing. (author)

  19. Analysis of output trends from Varian 2100C/D and 600C/D accelerators

    International Nuclear Information System (INIS)

    Grattan, M W D; Hounsell, A R

    2011-01-01

    Analysis of Varian linear accelerator output trends is reported. Two groups, consisting of four matched Varian 2100C/D and four matched Varian 600C/D accelerators, with different designs of monitor chamber, have been investigated and the data acquired from regular calibrated ion chamber/electrometer measurements of the output performance of the eight accelerators analysed. The trend of machine output with time, having removed the effect of adjusting the monitor chamber response, was compared on a monthly and annual basis for monitor chambers with ages ranging between 1 year and 7 years. The results indicate that the response is generally consistent within each set of accelerators with different monitor chamber designs. Those used in a Varian 600C/D machine result in a reduction in measured output over time, with an average monthly reduction of 0.35 ± 0.09% over the course of the first 4 years of use. The chambers used in a 2100C/D accelerator result in an increase in measured output over time, with an average monthly increase of 0.26 ± 0.09% over the course of the first 4 years of use. The output increase then reduces towards the end of this period of time, with the average monthly change falling to -0.03 ± 0.02% for the following 3 years. The output response trend was similar for all clinical energies used on the 2100C/D accelerators--6, 15 MV x-ray beams, and 4, 6, 9, 12, 16 and 20 MeV electron beams. By tracking these changes it has been possible to predict the response over time to allow appropriate adjustments in monitor chamber response to maintain a measured accelerator output within tolerance and give confidence in performance. It has also provided data to indicate the need for planned preventative intervention and indicate if the monitor chamber response is behaving as expected. (note)

  20. Successful use of levosimendan as a primary inotrope in pediatric cardiac surgery: An observational study in 110 patients

    Directory of Open Access Journals (Sweden)

    Reena Khantwal Joshi

    2016-01-01

    Conclusions: Levosimendan-based inotropic regime offers optimized cardiac output with a well-controlled heart rate and a low incidence of arrhythmias in patients undergoing all categories of congenital heart surgeries.

  1. Effect of cardiac function on aortic peak time and peak enhancement during coronary CT angiography

    International Nuclear Information System (INIS)

    Sakai, Shuji; Yabuuchi, Hidetake; Chishaki, Akiko; Okafuji, Takashi; Matsuo, Yoshio; Kamitani, Takeshi; Setoguchi, Taro; Honda, Hiroshi

    2010-01-01

    Purpose: To examine the manner in which cardiac function affects the magnitude and timing of aortic contrast enhancement during coronary CT angiography (CTA). Materials and methods: Twenty-nine patients (21 men, 8 women; mean age, 64.4 ± 13.4 years; mean weight, 59.4 ± 10.3 kg) underwent measurement of cardiac output within 2 weeks of coronary CTA. The cardiac output of each patient was measured by the thermodilution technique and the cardiac index was calculated from the body surface area. During coronary CTA, attenuation of the descending aorta was measured at the workstation every 3 s. The aortic peak time (APT) and aortic peak enhancement (APE) of each patient were calculated. Pearson's correlation coefficient analysis was used to investigate the relationships between the cardiac output or cardiac index and APT or APE. Furthermore, the relationship between patient factors or parameters on test bolus injection and APT or APE was also evaluated. Results: The range of cardiac output, cardiac index, APT, and APE was 1.55-10.46 L/min (mean: 4.77 ± 2.13), 1.11-5.30 L/(min-m 2 ) (mean: 3.28 ± 1.08), 25-51 s (mean: 38.3 ± 7.5), and 273.1-598.1 HU (mean: 390.4 ± 72.1), respectively. With an increase in the cardiac index, both APT (r = -0.698, p < 0.0001) and APE (r = -0.573, p = 0.0009) decreased. There were significant correlations between the patient body weight and APT and APE with the test bolus injection, and with APT and APE during coronary CTA. Conclusion: The APT and APE during coronary CTA are closely related to cardiac function.

  2. Cardiac involvement in canine babesiosis : review article

    Directory of Open Access Journals (Sweden)

    R.G. Lobetti

    2005-06-01

    Full Text Available Cardiac dysfunction in canine babesiosis has traditionally been regarded as a rare complication, with the majority of lesions reported as incidental findings at post-mortem examination. Recent studies have, however, demonstrated cardiac lesions in canine babesiosis. Cardiac troponins, especially troponin I, are sensitive markers of myocardial injury in canine babesiosis, and the magnitude of elevation of plasma troponin I concentrations appears to be proportional to the severity of the disease. ECG changes in babesiosis are similar to the pattern described for myocarditis and myocardial ischaemia and together with histopathological findings indicate that the heart suffers from the same pathological processes described in other organs in canine babesiosis, namely inflammation and hypoxia. The clinical application of the ECG appears to be limited and thus cardiovascular assessment should be based on functional monitoring rather than an ECG tracing. On cardiac histopathology from dogs that succumbed to babesiosis, haemorrhage, necrosis, inflammation and fibrin microthrombi in the myocardium were documented, all of which would have resulted in ECG changes and elevations in cardiac troponin. Myocardial damage causes left ventricular failure, which will result in hypotension and an expansion of the plasma volume due to homeostatic mechanisms.

  3. Cardiac function of the naked mole-rat: ecophysiological responses to working underground.

    Science.gov (United States)

    Grimes, Kelly M; Voorhees, Andrew; Chiao, Ying Ann; Han, Hai-Chao; Lindsey, Merry L; Buffenstein, Rochelle

    2014-03-01

    The naked mole-rat (NMR) is a strictly subterranean rodent with a low resting metabolic rate. Nevertheless, it can greatly increase its metabolic activity to meet the high energetic demands associated with digging through compacted soils in its xeric natural habitat where food is patchily distributed. We hypothesized that the NMR heart would naturally have low basal function and exhibit a large cardiac reserve, thereby mirroring the species' low basal metabolism and large metabolic scope. Echocardiography showed that young (2-4 yr old) healthy NMRs have low fractional shortening (28 ± 2%), ejection fraction (43 ± 2%), and cardiac output (6.5 ± 0.4 ml/min), indicating low basal cardiac function. Histology revealed large NMR cardiomyocyte cross-sectional area (216 ± 10 μm(2)) and cardiac collagen deposition of 2.2 ± 0.4%. Neither of these histomorphometric traits was considered pathological, since biaxial tensile testing showed no increase in passive ventricular stiffness. NMR cardiomyocyte fibers showed a low degree of rotation, contributing to the observed low NMR cardiac contractility. Interestingly, when the exercise mimetic dobutamine (3 μg/g ip) was administered, NMRs showed pronounced increases in fractional shortening, ejection fraction, cardiac output, and stroke volume, indicating an increased cardiac reserve. The relatively low basal cardiac function and enhanced cardiac reserve of NMRs are likely to be ecophysiological adaptations to life in an energetically taxing environment.

  4. Imaging for cardiac electrophysiology

    Directory of Open Access Journals (Sweden)

    Benoit Desjardins

    2016-11-01

    Full Text Available Clinical cardiac electrophysiology is the study of the origin and treatment of arrhythmia. There has been considerable recent development in this field, where imaging has had a transformational impact. In this invited review, we offer a global overview of the most important developments in the use of imaging in cardiac electrophysiology. We first describe the radiological imaging modalities involved in cardiac electrophysiology, to assess cardiac anatomy, function and scar. We then introduce an imaging modality with which readers are probably unfamiliar (electroanatomical mapping [EAM], but which is routinely used by electrophysiologists to plan and guide cardiac mapping and cardiac ablation therapy by catheter, a therapy which can reduce or even cure arrhythmia. We identify the limitations of EAM and describe how radiological imaging modalities can complement this technique. We then describe and illustrate how imaging has helped the diagnosis of arrhythmogenic conditions, and how imaging is used to plan and guide clinical cardiac electrophysiologic procedures and assess their results and complications. We focus on the two most common arrhythmias for which imaging has the greatest impact: atrial fibrillation and ventricular tachycardia.

  5. Cardiac tumors: echo assessment

    Directory of Open Access Journals (Sweden)

    Rekha Mankad MD

    2016-12-01

    Full Text Available Cardiac tumors are exceedingly rare (0.001–0.03% in most autopsy series. They can be present anywhere within the heart and can be attached to any surface or be embedded in the myocardium or pericardial space. Signs and symptoms are nonspecific and highly variable related to the localization, size and composition of the cardiac mass. Echocardiography, typically performed for another indication, may be the first imaging modality alerting the clinician to the presence of a cardiac mass. Although echocardiography cannot give the histopathology, certain imaging features and adjunctive tools such as contrast imaging may aid in the differential diagnosis as do the adjunctive clinical data and the following principles: (1 thrombus or vegetations are the most likely etiology, (2 cardiac tumors are mostly secondary and (3 primary cardiac tumors are mostly benign. Although the finding of a cardiac mass on echocardiography may generate confusion, a stepwise approach may serve well practically. Herein, we will review such an approach and the role of echocardiography in the assessment of cardiac masses.

  6. Endogenous Natural Complement Inhibitor Regulates Cardiac Development

    DEFF Research Database (Denmark)

    Mortensen, Simon A; Skov, Louise L; Kjaer-Sorensen, Kasper

    2017-01-01

    mechanisms during fetal development and adult homeostasis. In this article, we describe the function of an endogenous complement inhibitor, mannan-binding lectin (MBL)-associated protein (MAp)44, in regulating the composition of a serine protease-pattern recognition receptor complex, MBL-associated serine...... of MAp44 caused impaired cardiogenesis, lowered heart rate, and decreased cardiac output. These defects were associated with aberrant neural crest cell behavior. We found that MAp44 competed with MASP-3 for pattern recognition molecule interaction, and knockdown of endogenous MAp44 expression could...

  7. Assessing quality in cardiac surgery

    Directory of Open Access Journals (Sweden)

    Samer A.M. Nashef

    2005-07-01

    Full Text Available There is a the strong temporal, if not causal, link between the intervention and the outcome in cardiac surgery and therefore a link becomes established between operative mortality and the measurement of surgical performance. In Britain the law stipulates that data collected by any public body or using public funds must be made freely available. Tools and mechanisms we devise and develop are likely to form the models on which the quality of care is assessed in other surgical and perhaps medical specialties. Measuring professional performance should be done by the profession. To measure risk there are a number of scores as crude mortality is not enough. A very important benefit of assessing the risk of death is to use this knowledge in the determination of the indication to operate. The second benefit is in the assessment of the quality of care as risk prediction gives a standard against performance of hospitals and surgeons. Peer review and “naming and shaming” are two mechanisms to monitor quality. There are two potentially damaging outcomes from the publication of results in a league-table form: the first is the damage to the hospital; the second is to refuse to operate on high-risk patients. There is a real need for quality monitoring in medicine in general and in cardiac surgery in particular. Good quality surgical work requires robust knowledge of three crucial variables: activity, risk prediction and performance. In Europe, the three major specialist societies have agreed to establish the European Cardiovascular and Thoracic Surgery Institute of Accreditation (ECTSIA. Performance monitoring is soon to become imperative. If we surgeons are not on board, we shall have no control on its final destination, and the consequences may be equally damaging to us and to our patients.

  8. Early-Transition Output Decline Revisited

    Directory of Open Access Journals (Sweden)

    Crt Kostevc

    2016-05-01

    Full Text Available In this paper we revisit the issue of aggregate output decline that took place in the early transition period. We propose an alternative explanation of output decline that is applicable to Central- and Eastern-European countries. In the first part of the paper we develop a simple dynamic general equilibrium model that builds on work by Gomulka and Lane (2001. In particular, we consider price liberalization, interpreted as elimination of distortionary taxation, as a trigger of the output decline. We show that price liberalization in interaction with heterogeneous adjustment costs and non-employment benefits lead to aggregate output decline and surge in wage inequality. While these patterns are consistent with actual dynamics in CEE countries, this model cannot generate output decline in all sectors. Instead sectors that were initially taxed even exhibit output growth. Thus, in the second part we consider an alternative general equilibrium model with only one production sector and two types of labor and distortion in a form of wage compression during the socialist era. The trigger for labor mobility and consequently output decline is wage liberalization. Assuming heterogeneity of workers in terms of adjustment costs and non-employment benefits can explain output decline in all industries.

  9. Assessing the psychological factors predicting workers' output ...

    African Journals Online (AJOL)

    The study investigated job security, communication skills, interpersonal relationship and emotional intelligence as correlates of workers' output among local government employees in Oyo State. The research adopted descriptive design of an expose facto type. The research instruments used includes Workers' output scale, ...

  10. Exact nonradial input, output, and productivity measurement

    OpenAIRE

    Robert G. Chambers

    2002-01-01

    The use of measures originally suggested by Bennet, Bowley, and Hicks in the context of cost of living, welfare, and consumer surplus measurement to measure inputs, outputs, and productivity is examined. Suitably normalized versions of the Bennet-Bowley measures are shown to be exact and superlative measures of input, output, and productivity indicators.

  11. DIST/AVC Out-Put Definition.

    Science.gov (United States)

    Wilkinson, Gene L.

    The first stage of development of a management information system for DIST/AVC (Division of Instructional Technology/Audio-Visual Center) is the definition of out-put units. Some constraints on the definition of output units are: 1) they should reflect goals of the organization, 2) they should reflect organizational structure and procedures, and…

  12. Role of Nuclear Medicine in the cardiac resinchronization therapy

    Energy Technology Data Exchange (ETDEWEB)

    Brandao, Simone Cristina Soares, E-mail: simonecordis@yahoo.com.br [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil); Giorgi, Maria Clementina Pinto; D' Orio, Silvana Angelina; Meneghetti, Jose Claudio [Instituto do Coracao (InCor/FM/USP), Sao Paulo, SP (Brazil)

    2011-10-15

    Cardiac resynchronization therapy (CRT) emerged as one of the most promising approaches in the treatment of cardiac dyssynchrony in heart failure patients' refractory to medical treatment. However, despite very promising clinical and functional results, individual response analyses show that a significant number of patients do not respond to treatment. The role of nuclear medicine and molecular imaging in the selection of CRT candidates by the assessment of cardiac dyssynchrony, myocardial viability, myocardial perfusion and blood flow and sympathetic cardiac activity has been discussed in this review. The potential utilization of this tool to improve the comprehension of detrimental effects of dyssynchrony on cardiac function and the evaluation and monitoring of the response to CRT were also considered. Other molecular targets that characterize glucose and fatty acid metabolism, apoptosis, angiotensin converting enzyme activity and angiogenesis that can be evaluated with this technique were described. (author)

  13. The left ventricle as a mechanical engine: from Leonardo da Vinci to the echocardiographic assessment of peak power output-to-left ventricular mass.

    Science.gov (United States)

    Dini, Frank L; Guarini, Giacinta; Ballo, Piercarlo; Carluccio, Erberto; Maiello, Maria; Capozza, Paola; Innelli, Pasquale; Rosa, Gian M; Palmiero, Pasquale; Galderisi, Maurizio; Razzolini, Renato; Nodari, Savina

    2013-03-01

    The interpretation of the heart as a mechanical engine dates back to the teachings of Leonardo da Vinci, who was the first to apply the laws of mechanics to the function of the heart. Similar to any mechanical engine, whose performance is proportional to the power generated with respect to weight, the left ventricle can be viewed as a power generator whose performance can be related to left ventricular mass. Stress echocardiography may provide valuable information on the relationship between cardiac performance and recruited left ventricular mass that may be used in distinguishing between adaptive and maladaptive left ventricular remodeling. Peak power output-to-mass, obtained during exercise or pharmacological stress echocardiography, is a measure that reflects the number of watts that are developed by 100 g of left ventricular mass under maximal stimulation. Power output-to-mass may be calculated as left ventricular power output per 100 g of left ventricular mass: 100× left ventricular power output divided by left ventricular mass (W/100 g). A simplified formula to calculate power output-to-mass is as follows: 0.222 × cardiac output (l/min) × mean blood pressure (mmHg)/left ventricular mass (g). When the integrity of myocardial structure is compromised, a mismatch becomes apparent between maximal cardiac power output and left ventricular mass; when this occurs, a reduction of the peak power output-to-mass index is observed.

  14. Perceiving imitatible stimuli: consequences of isomorphism between input and output.

    Science.gov (United States)

    Wilson, M

    2001-07-01

    For more than a century, psychologists have been intrigued by the idea that mental representations of perceived human actions are closely connected with mental representations of performing those same actions. In this article, connections between input and output representations are considered in terms of the potential for imitation. A broad range of evidence suggests that, for imitatible stimuli, input and output representations are isomorphic to one another, allowing mutual influence between perception and motoric planning that is rapid, effortless, and possibly obligatory. Thus, the cognitive consequences of imitatibility may underlie such diverse phenomena as phoneme perception; imitation in neonates; echoic memory; stimulus-response compatibility; conduction aphasia; maintenance rehearsal; and a variety of developmental and social activities such as language acquisition, social learning, empathy, and monitoring one's own behavior.

  15. Outcomes after in-hospital cardiac arrest in children with cardiac disease: a report from Get With the Guidelines--Resuscitation.

    Science.gov (United States)

    Ortmann, Laura; Prodhan, Parthak; Gossett, Jeffrey; Schexnayder, Stephen; Berg, Robert; Nadkarni, Vinay; Bhutta, Adnan

    2011-11-22

    Small studies suggest that children experiencing a cardiac arrest after undergoing cardiac surgery have better outcomes than other groups of patients, but the survival outcomes and periarrest variables of cardiac and noncardiac pediatric patients have not been compared. All cardiac arrests in patients <18 years of age were identified from Get With the Guidelines-Resuscitation from 2000 to 2008. Cardiac arrests occurring in the neonatal intensive care unit were excluded. Of 3323 index cardiac arrests, 19% occurred in surgical-cardiac, 17% in medical-cardiac, and 64% in noncardiac (trauma, surgical-noncardiac, and medical-noncardiac) patients. Survival to hospital discharge was significantly higher in the surgical-cardiac group (37%) compared with the medical-cardiac group (28%; adjusted odds ratio, 1.8; 95% confidence interval, 1.3-2.5) and the noncardiac group (23%; adjusted odds ratio, 1.8; 95% confidence interval, 1.4-2.4). Those in the cardiac groups were younger and less likely to have preexisting noncardiac organ dysfunction, but were more likely to have ventricular arrhythmias as their first pulseless rhythm, to be monitored and hospitalized in the intensive care unit at the time of cardiac arrest, and to have extracorporeal cardiopulmonary resuscitation compared with those in the noncardiac group. There was no survival advantage for patients in the medical-cardiac group compared with those in the noncardiac group when adjusted for periarrest variables. Children with surgical-cardiac disease have significantly better survival to hospital discharge after an in-hospital cardiac arrest compared with children with medical-cardiac disease and noncardiac disease.

  16. Disentangling input and output-related components of spatial neglect

    Science.gov (United States)

    Loetscher, Tobias; Nicholls, Michael E. R.; Brodtmann, Amy; Thomas, Nicole A.; Brugger, Peter

    2012-01-01

    Spatial neglect is a heterogeneous disorder with a multitude of manifestations and subtypes. Common clinical paper and pencil neglect tests fail to differentiate between these subtypes. For example, neglect patients typically bisect lines to the right. This bias can be caused by an underestimation of the left half of the line (input-related deficit), by the failure to direct actions toward the left side of space (output-related deficit), or by a mixture of these impairments. To disentangle these impairments, we used a test consisting of a line bisection task on a touch screen monitor (manual motor task) and the subsequent judgment of one's own bisection performance (visual perceptual task). It was hypothesized that patients with mainly output-related neglect should be better able to recognize their misbisected lines than patients with purely input-related neglect. In a group of 16 patients suffering from spatial neglect after right brain damage, we found that patients were three times more likely to suffer from a predominantly input-related than from an output-related subtype. The results thus suggest that neglect is typically an input-related impairment. Additional analysis of the line bisection task revealed that temporal (slowness in initiation and execution of contralateral movements) and spatial (insufficient movement amplitude toward the contralesional side) aspects of output-related neglect were mutually unrelated. This independence raises the possibility that a fine-grained differentiation of output-related neglect is required. That is, impairments in lateralized temporal and spatial aspects of movements may underlie different neglect subtypes. PMID:22707937

  17. Buerger's Disease and Anaesthesia: The Neglected Cardiac Angle

    Directory of Open Access Journals (Sweden)

    Shagun Bhatia Shah

    2015-08-01

    Full Text Available Distal limb amputations and respiratory complications are common in patients with Buerger’s disease. Nicotine in cigarette is arrhythmogenic as it blocks cardiac potassium channels. Preoperative Holter ECG monitoring may be useful if preoperative electrocardiogram is normal. If the patient is undergoing major surgery, preservative free lignocaine & amiodarone infusions and a cardioverter defibrillator should be available for the intraoperative cardiac rhythm disturbances.

  18. Socially differentiated cardiac rehabilitation

    DEFF Research Database (Denmark)

    Meillier, Lucette Kirsten; Nielsen, Kirsten Melgaard; Larsen, Finn Breinholt

    2012-01-01

    cardiac rehabilitation programme. Methods: From 1 September 2002 to 31 December 2005, 388 first-incidence MI patients ≤75 years were hospitalised. Register check for newly hospitalised MI patients, screening interview, and systematic referral were conducted by a project nurse. Patients were referred...... to a standard rehabilitation programme (SRP). If patients were identified as socially vulnerable, they were offered an extended version of the rehabilitation programme (ERP). Excluded patients were offered home visits by a cardiac nurse. Concordance principles were used in the individualised programme elements......Aim: The comprehensive cardiac rehabilitation (CR) programme after myocardial infarction (MI) improves quality of life and results in reduced cardiac mortality and recurrence of MI. Hospitals worldwide face problems with low participation rates in rehabilitation programmes. Inequality...

  19. Cardiac Procedures and Surgeries

    Science.gov (United States)

    ... the Procedure Does A stent is a wire mesh tube used to prop open an artery during ... a Heart Attack • Heart Attack Tools & Resources • Support Network Heart Attack Tools & Resources My Cardiac Coach What ...

  20. Defining the Cardiac Fibroblast

    Science.gov (United States)

    Ivey, Malina J.; Tallquist, Michelle D.

    2017-01-01

    Cardiac fibrosis remains an important health concern, but the study of fibroblast biology has been hindered by a lack of effective means for identifying and tracking fibroblasts. Recent advances in fibroblast-specific lineage tags and reporters have permitted a better understanding of these cells. After injury multiple cell types have been implicated as the source for extracellular matrix producing cells, but emerging studies suggest that resident cardiac fibroblasts contribute substantially to the remodeling process. In this review, we discuss recent findings regarding cardiac fibroblast origin and identity. Our understanding of cardiac fibroblast biology and fibrosis is still developing and will expand profoundly in the next few years, with many of the recent findings regarding fibroblast gene expression and behavior laying down the groundwork for interpreting the purpose and utility of these cells before and after injury. PMID:27746422

  1. Cardiac Catheterization (For Parents)

    Science.gov (United States)

    ... cases, the doctor might call for a cardiac magnetic resonance imaging (MRI) scan or a CAT scan . ... first couple of days. This means no heavy lifting (more than 10 pounds) and no sports. After ...

  2. Cardiac Catheterization (For Teens)

    Science.gov (United States)

    ... doctor may also call for a cardiac MRI (magnetic resonance imaging) scan or a CT (computerized tomography) ... first couple of days. This means no heavy lifting (nothing over 10 pounds) and no sports. After ...

  3. Anxiety in Patients with Cardiac Disease

    Science.gov (United States)

    2005-01-01

    the patients were divided into high and low anxiety subgroups . As shown in Table 4.3, mean systolic blood pressure, diastolic blood pressure, and heart...rate were not statistically different for patients in the high and low anxiety subgroups , regardless of the presence or absence of cardiac disease...monitoring sleep and activity levels in patients with fibromyalgia and depression. JPsychosom Res. 2002;52:439-443. 19. Mason DJ, Redeker N. Measurement of

  4. High Output Piezo/Triboelectric Hybrid Generator

    Science.gov (United States)

    Jung, Woo-Suk; Kang, Min-Gyu; Moon, Hi Gyu; Baek, Seung-Hyub; Yoon, Seok-Jin; Wang, Zhong-Lin; Kim, Sang-Woo; Kang, Chong-Yun

    2015-03-01

    Recently, piezoelectric and triboelectric energy harvesting devices have been developed to convert mechanical energy into electrical energy. Especially, it is well known that triboelectric nanogenerators have a simple structure and a high output voltage. However, whereas nanostructures improve the output of triboelectric generators, its fabrication process is still complicated and unfavorable in term of the large scale and long-time durability of the device. Here, we demonstrate a hybrid generator which does not use nanostructure but generates much higher output power by a small mechanical force and integrates piezoelectric generator into triboelectric generator, derived from the simultaneous use of piezoelectric and triboelectric mechanisms in one press-and-release cycle. This hybrid generator combines high piezoelectric output current and triboelectric output voltage, which produces peak output voltage of ~370 V, current density of ~12 μA.cm-2, and average power density of ~4.44 mW.cm-2. The output power successfully lit up 600 LED bulbs by the application of a 0.2 N mechanical force and it charged a 10 μF capacitor to 10 V in 25 s. Beyond energy harvesting, this work will provide new opportunities for developing a small, built-in power source in self-powered electronics such as mobile electronics.

  5. High Output Piezo/Triboelectric Hybrid Generator

    Science.gov (United States)

    Jung, Woo-Suk; Kang, Min-Gyu; Moon, Hi Gyu; Baek, Seung-Hyub; Yoon, Seok-Jin; Wang, Zhong-Lin; Kim, Sang-Woo; Kang, Chong-Yun

    2015-01-01

    Recently, piezoelectric and triboelectric energy harvesting devices have been developed to convert mechanical energy into electrical energy. Especially, it is well known that triboelectric nanogenerators have a simple structure and a high output voltage. However, whereas nanostructures improve the output of triboelectric generators, its fabrication process is still complicated and unfavorable in term of the large scale and long-time durability of the device. Here, we demonstrate a hybrid generator which does not use nanostructure but generates much higher output power by a small mechanical force and integrates piezoelectric generator into triboelectric generator, derived from the simultaneous use of piezoelectric and triboelectric mechanisms in one press-and-release cycle. This hybrid generator combines high piezoelectric output current and triboelectric output voltage, which produces peak output voltage of ~370 V, current density of ~12 μA·cm−2, and average power density of ~4.44 mW·cm−2. The output power successfully lit up 600 LED bulbs by the application of a 0.2 N mechanical force and it charged a 10 μF capacitor to 10 V in 25 s. Beyond energy harvesting, this work will provide new opportunities for developing a small, built-in power source in self-powered electronics such as mobile electronics. PMID:25791299

  6. Cardiac biomarkers in Neonatology

    OpenAIRE

    Vijlbrief, D.C.

    2015-01-01

    In this thesis, the role for cardiac biomarkers in neonatology was investigated. Several clinically relevant results were reported. In term and preterm infants, hypoxia and subsequent adaptation play an important role in cardiac biomarker elevation. The elevated natriuretic peptides are indicative of abnormal function; elevated troponins are suggestive for cardiomyocyte damage. This methodology makes these biomarkers of additional value in the treatment of newborn infants, separate or as a co...

  7. Cardiac imaging in adults

    International Nuclear Information System (INIS)

    Jaffe, C.C.

    1987-01-01

    This book approaches adult cardiac disease from the correlative imaging perspective. It includes chest X-rays and angiographs, 2-dimensional echocardiograms with explanatory diagrams for clarity, plus details on digital radiology, nuclear medicine techniques, CT and MRI. It also covers the normal heart, valvular heart disease, myocardial disease, pericardial disease, bacterial endocarditis, aortic aneurysm, cardiac tumors, and congenital heart disease of the adult. It points out those aspects where one imaging technique has significant superiority

  8. Cardiac imaging in adults

    Energy Technology Data Exchange (ETDEWEB)

    Jaffe, C.C.

    1987-01-01

    This book approaches adult cardiac disease from the correlative imaging perspective. It includes chest X-rays and angiographs, 2-dimensional echocardiograms with explanatory diagrams for clarity, plus details on digital radiology, nuclear medicine techniques, CT and MRI. It also covers the normal heart, valvular heart disease, myocardial disease, pericardial disease, bacterial endocarditis, aortic aneurysm, cardiac tumors, and congenital heart disease of the adult. It points out those aspects where one imaging technique has significant superiority.

  9. Awareness in cardiac anesthesia.

    LENUS (Irish Health Repository)

    Serfontein, Leon

    2010-02-01

    Cardiac surgery represents a sub-group of patients at significantly increased risk of intraoperative awareness. Relatively few recent publications have targeted the topic of awareness in this group. The aim of this review is to identify areas of awareness research that may equally be extrapolated to cardiac anesthesia in the attempt to increase understanding of the nature and significance of this scenario and how to reduce it.

  10. Peri-operative troponin monitoring using a prototype high-sensitivity cardiac troponin I (hs-cTnI) assay: comparisons with hs-cTnT and contemporary cTnI assays.

    LENUS (Irish Health Repository)

    Lee, Graham R

    2013-09-18

    Non-cardiac surgery is associated with major vascular complications and higher incidences of elevated plasma troponin (cTn) concentration. Goal-directed therapy (GDT) is a stroke volume (SV)-guided approach to intravenous (IV) fluid therapy that improves tissue perfusion, oxygenation and reduces post-operative complications. In patients undergoing major gastro-intestinal surgery, we compared high sensitive and contemporary troponin assays and correlated results with patient outcome.

  11. Cardiac arrhythmia detection using photoplethysmography.

    Science.gov (United States)

    Paradkar, Neeraj; Chowdhury, Shubhajit Roy

    2017-07-01

    Cardiovascular Diseases (CVDs) cause a very large number of casualties around the world every year and cardiac arrhythmias contribute to significant proportion of CVD related deaths. Bedside cardiac activity monitors in hospitals are based on electrocardiogram (ECG) processing and are known to produce too many false alarms. Moving beyond bedside care, ECG is not very suitable for use in wearable devices. Photoplethysmography (PPG) on the other hand provides an inexpensive and more wearable device-friendly alternative. This work presents a technique to detect life threatening arrhythmias using only PPG waveforms. PhysioNet Challenge 2015 data is used to detect five types of arrhythmias namely, tachycardia, bradycardia, asystole, ventricular tachycardia and ventricular fibrillation. A novel technique is employed to assign pulse quality index to every PPG pulse and highest quality portion of the signal is used for detection. Results indicate that PPG provides a viable alternative for conventional ECG based detection. An overall true positive rate (TPR) of 93% was achieved with true negative rate (TNR) of 53.78% suggesting that PPG is a viable option for arrhythmia detection.

  12. Design of hydraulic output Stirling engine

    Science.gov (United States)

    Toscano, W. M.; Harvey, A. C.; Lee, K.

    1983-01-01

    A hydraulic output system for the RE-1000 free piston stirling engine (FPSE) was designed. The hydraulic output system can be readily integrated with the existing hot section of RE-1000 FPSE. The system has two simply supported diaphragms which separate the engine gas from the hydraulic fluid, a dynamic balance mechanism, and a novel, null center band hydraulic pump. The diaphragms are designed to endure more than 10 billion cycles, and to withstand the differential pressure load as high as 14 MPa. The projected thermodynamic performance of the hydraulic output version of RE-1000 FPSE is 1.87 kW at 29/7 percent brake efficiency.

  13. Magnetic resonance imaging in patients with cardiac pacemakers: era of "MR Conditional" designs

    Directory of Open Access Journals (Sweden)

    Shellock Frank G

    2011-10-01

    Full Text Available Abstract Advances in cardiac device technology have led to the first generation of magnetic resonance imaging (MRI conditional devices, providing more diagnostic imaging options for patients with these devices, but also new controversies. Prior studies of pacemakers in patients undergoing MRI procedures have provided groundwork for design improvements. Factors related to magnetic field interactions and transfer of electromagnetic energy led to specific design changes. Ferromagnetic content was minimized. Reed switches were modified. Leads were redesigned to reduce induced currents/heating. Circuitry filters and shielding were implemented to impede or limit the transfer of certain unwanted electromagnetic effects. Prospective multicenter clinical trials to assess the safety and efficacy of the first generation of MR conditional cardiac pacemakers demonstrated no significant alterations in pacing parameters compared to controls. There were no reported complications through the one month visit including no arrhythmias, electrical reset, inhibition of generator output, or adverse sensations. The safe implementation of these new technologies requires an understanding of the well-defined patient and MR system conditions. Although scanning a patient with an MR conditional device following the strictly defined patient and MR system conditions appears straightforward, issues related to patients with pre-existing devices remain complex. Until MR conditional devices are the routine platform for all of these devices, there will still be challenging decisions regarding imaging patients with pre-existing devices where MRI is required to diagnose and manage a potentially life threatening or serious scenario. A range of other devices including ICDs, biventricular devices, and implantable physiologic monitors as well as guidance of medical procedures using MRI technology will require further biomedical device design changes and testing. The development and

  14. [Factors involved in the development of vasoplegia after cardiac surgery with extracorporeal circulation. A prospective observational study].

    Science.gov (United States)

    Durán Bruce, M; Gomar Sancho, C; Holguera, J C; Muliterno Español, E

    2014-05-01

    The incidence and risk factors for vasoplegia in the early postoperative period and at 24h are investigated in patients subjected to cardiopulmonary bypass surgery. Vasoplegia following cardiac surgery with cardiopulmonary bypass is associated with a high morbimortality. The risk factors described emerged from retrospective, non-controlled studies. Observational prospective study of 188 consecutive patients subjected to cardiac surgery with cardiopulmonary bypass in a single hospital between November 2011 and May 2012. Emergency surgery or complex procedures were excluded. Vasoplegia was assessed during the immediate postoperative period, and at 24h after surgery, and was defined as a mean arterial pressure below 50mmHg, and the need for a noradrenaline perfusion of more than 0.08μg/kg/min, monitored by cardiac output and systemic vascular resistances. The anaesthetic and cardiopulmonary bypass protocols, as well as haemodynamic management, were the same in all patients. Almost half (48%) of patients had vasoplegia in the immediate postoperative period, and 34% at 24h. Risk factors for immediate vasoplegia development were preoperative use of angiotensin converting enzyme inhibitor drugs, a mean arterial pressure<50mmHg immediately after beginning cardiopulmonary bypass, duration of aortic clamping as well as the cardiopulmonary bypass, and minimum temperature in cardiopulmonary bypass. Vasoplegia at 24h after surgery was correlated to preoperative angiotensin converting enzyme inhibitor drug treatment and cardiopulmonary bypass duration. The incidence of vasoplegia after cardiac surgery with cardiopulmonary bypass is high during the first 24 postoperative hours. Preoperative treatment with angiotensin converting enzyme inhibitor and the mean arterial pressure at the beginning of cardiopulmonary bypass are the more easily controllable risk factors. In patients arriving to surgery with those drugs, treatment or prevention of vasoplejia should be planned. Copyright

  15. Fractals analysis of cardiac arrhythmias.

    Science.gov (United States)

    Saeed, Mohammed

    2005-09-06

    Heart rhythms are generated by complex self-regulating systems governed by the laws of chaos. Consequently, heart rhythms have fractal organization, characterized by self-similar dynamics with long-range order operating over multiple time scales. This allows for the self-organization and adaptability of heart rhythms under stress. Breakdown of this fractal organization into excessive order or uncorrelated randomness leads to a less-adaptable system, characteristic of aging and disease. With the tools of nonlinear dynamics, this fractal breakdown can be quantified with potential applications to diagnostic and prognostic clinical assessment. In this paper, I review the methodologies for fractal analysis of cardiac rhythms and the current literature on their applications in the clinical context. A brief overview of the basic mathematics of fractals is also included. Furthermore, I illustrate the usefulness of these powerful tools to clinical medicine by describing a novel noninvasive technique to monitor drug therapy in atrial fibrillation.

  16. Endogenous Money, Output and Prices in India

    OpenAIRE

    Das, Rituparna

    2009-01-01

    This paper proposes to quantify the macroeconometric relationships among the variables broad money, lending by banks, price, and output in India using simultaneous equations system keeping in view the issue of endogeneity.

  17. Multiple Input - Multiple Output (MIMO) SAR

    Data.gov (United States)

    National Aeronautics and Space Administration — This effort will research and implement advanced Multiple-Input Multiple-Output (MIMO) Synthetic Aperture Radar (SAR) techniques which have the potential to improve...

  18. Neonatal Hemodynamics: From Developmental Physiology to Comprehensive Monitoring

    Directory of Open Access Journals (Sweden)

    Sabine L. Vrancken

    2018-04-01

    Full Text Available Maintenance of neonatal circulatory homeostasis is a real challenge, due to the complex physiology during postnatal transition and the inherent immaturity of the cardiovascular system and other relevant organs. It is known that abnormal cardiovascular function during the neonatal period is associated with increased risk of severe morbidity and mortality. Understanding the functional and structural characteristics of the neonatal circulation is, therefore, essential, as therapeutic hemodynamic interventions should be based on the assumed underlying (pathophysiology. The clinical assessment of systemic blood flow (SBF by indirect parameters, such as blood pressure, capillary refill time, heart rate, urine output, and central-peripheral temperature difference is inaccurate. As blood pressure is no surrogate for SBF, information on cardiac output and systemic vascular resistance should be obtained in combination with an evaluation of end organ perfusion. Accurate and reliable hemodynamic monitoring systems are required to detect inadequate tissue perfusion and oxygenation at an early stage before this result in irreversible damage. Also, the hemodynamic response to the initiated treatment should be re-evaluated regularly as changes in cardiovascular function can occur quickly. New insights in the understanding of neonatal cardiovascular physiology are reviewed and several methods for current and future neonatal hemodynamic monitoring are discussed.

  19. Biomedical Monitoring by a Novel Noncontact Radio Frequency Technology Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This technology will be a quantum advance in cardiac monitoring and will be applicable in numerous situations such as for immediate assessment and monitoring of...

  20. [Preoperative cardiac-risk assessment for non-cardiac surgery: The French RICARDO survey].

    Science.gov (United States)

    Sens, N; Payan, A; Sztark, F; Piriou, V; Bouaziz, H; Bruder, N; Jaber, S; Jouffroy, L; Lebuffe, G; Mantz, J; Piriou, V; Roche, S; Sztark, F; Tauzin-Fin, F

    2013-10-01

    Professional practice evaluation of anaesthesiologist for high cardiac-risk patient cares in non-cardiac surgery, and assess disparities between results and recommendations. Since June to September 2011, a self-questionnaire was sent to 5000 anesthesiologist. They were considered to be representative of national anesthesiology practitioner. Different items investigated concerned: demography, preoperative cardiac-risk assessment, modalities of specialized cardiologic advice, per- and postoperative care, and finally knowledge of current recommendations. We collected 1255 questionnaire, that is to say 25% of answers. Men were 73%, 38% were employed by public hospital; 70% worked in a shared operating theatre with a general activity. With regards to preoperative assessment, 85% of anaesthetists referred high cardiac-risk patient to a cardiologist. In only 16% of answer, Lee's score appeared in anaesthesia file to assess perioperative cardiac-risk. Only 61% considered the six necessary items to optimal estimate of cardiac-risk. On the other hand, 91% measured routinely the exercise capacities by interrogation. The most frequently doing exam (49% of anaesthetist) was an electrocardiogram in elderly patient. In 96% of case, beta-blockers were given in premedication if they were usually thought. Clopidogrel was stopped by 62% of anesthetist before surgery. In this case, 38% used another medication to take over from this one. Only 7% considered revascularization in coronary patient who were effectively treated. POISE study was know by 40% of practitioner, and 18% estimated that they have changed their practice. Preoperatively, 21% organized multidisciplinary approach for high-risk patient. During surgery, 63% monitored the ST-segment. In postoperative period for cardiac-risk patient, only 11% prescribed systematically an ECG, a troponin dosage, a postoperative monitoring of ST-segment, a cardiologic advice. In case of moderate troponin elevation, they were 70% to realize at

  1. Predicting Output Power for Nearshore Wave Energy Harvesting

    Directory of Open Access Journals (Sweden)

    Henock Mamo Deberneh

    2018-04-01

    Full Text Available Energy harvested from a Wave Energy Converter (WEC varies greatly with the location of its installation. Determining an optimal location that can result in maximum output power is therefore critical. In this paper, we present a novel approach to predicting the output power of a nearshore WEC by characterizing ocean waves using floating buoys. We monitored the movement of the buoys using an Arduino-based data collection module, including a gyro-accelerometer sensor and a wireless transceiver. The collected data were utilized to train and test prediction models. The models were developed using machine learning algorithms: SVM, RF and ANN. The results of the experiments showed that measurements from the data collection module can yield a reliable predictor of output power. Furthermore, we found that the predictors work better when the regressors are combined with a classifier. The accuracy of the proposed prediction model suggests that it could be extremely useful in both locating optimal placement for wave energy harvesting plants and designing the shape of the buoys used by them.

  2. Dependency of blood pressure upon cardiac filling in patients with severe postural hypotension

    DEFF Research Database (Denmark)

    Mehlsen, J; Haedersdal, C; Stokholm, K H

    1994-01-01

    by vasoconstriction. The reduction in cardiac output resulted from reductions in left ventricular end-diastolic volumes with unchanged left ventricular ejection fractions and only moderate increments in heart rate. The study was demonstrated that blood pressure is strongly dependent upon cardiac filling in severe......Autonomic denervation of the vascular bed results theoretically in a stronger dependency of blood pressure upon intravascular volume, and the study described aimed at an investigation of the relation between cardiac filling and arterial blood pressure in patients with severe postural hypotension....... Seven patients were studied during head-up tilt at three different tilt angles using intra-arterial blood pressure recordings and estimates of left ventricular volumes by radioisotope ventriculography. Blood pressure fell dramatically during head-up tilt due to reductions in cardiac output unopposed...

  3. Cardiac radiology: centenary review.

    Science.gov (United States)

    de Roos, Albert; Higgins, Charles B

    2014-11-01

    During the past century, cardiac imaging technologies have revolutionized the diagnosis and treatment of acquired and congenital heart disease. Many important contributions to the field of cardiac imaging were initially reported in Radiology. The field developed from the early stages of cardiac imaging, including the use of coronary x-ray angiography and roentgen kymography, to nowadays the widely used echocardiographic, nuclear medicine, cardiac computed tomographic (CT), and magnetic resonance (MR) applications. It is surprising how many of these techniques were not recognized for their potential during their early inception. Some techniques were described in the literature but required many years to enter the clinical arena and presently continue to expand in terms of clinical application. The application of various CT and MR contrast agents for the diagnosis of myocardial ischemia is a case in point, as the utility of contrast agents continues to expand the noninvasive characterization of myocardium. The history of cardiac imaging has included a continuous process of advances in our understanding of the anatomy and physiology of the cardiovascular system, along with advances in imaging technology that continue to the present day.

  4. Central venous oxygen saturation and thoracic admittance during dialysis: new approaches to hemodynamic monitoring

    DEFF Research Database (Denmark)

    Cordtz, J.; Olde, B.; Solem, K.

    2008-01-01

    events are reflected in the central venous oxygen saturation (ScO(2)) and thoracic admittance (TA) during dialysis. Twenty ambulatory HD patients, 11 hypotension prone (HP) and 9 hypotension resistant, with central vascular access, were monitored during 3 HD sessions each. ScO(2), TA, finger blood...... in ScO(2) and TA correlated much closer than did changes in ScO(2) and DeltaBV (r=0.43 and 0.18, respectively). Our results suggest that an intradialytic decrease in cardiac output, as reflected by a fall in ScO(2), is a common feature to HD patients prone to IDH. In patients using a central vascular...... access, ScO(2) and TA measurements may be more specific to the pathophysiologic events preceding IDH than DeltaBV-the current standard monitoring method Udgivelsesdato: 2008/7...

  5. Cardiac contractility, central haemodynamics and blood pressure regulation during semistarvation

    DEFF Research Database (Denmark)

    Stokholm, K H; Breum, L; Astrup, A

    1991-01-01

    and equilibrium technique by [99Tcm]red blood cells). Cardiac output decreased concomitantly with the reduction in oxygen uptake as the calculated systemic arteriovenous difference of oxygen was unaltered. There were no significant decreases in left ventricular contractility indices, i.e. the ejection fraction......Eight obese patients were studied before and after 2 weeks of treatment by a very-low-calorie diet (VLCD). Cardiac output and central blood volume (pulmonary blood volume and left atrial volume) were determined by indicator dilution (125I-albumin) and radionuclide angiocardiography (first pass......, the peak ejection rate and changes in end-systolic volume. Also the diastolic function evaluated by the peak filling rate remained normal. Furthermore, no sign of backward failure could be demonstrated since the central blood volume was not significantly increased. Both systolic and diastolic blood...

  6. Cardiac safety in vascular access surgery and maintenance.

    Science.gov (United States)

    Malik, Jan; Kudlicka, Jaroslav; Tesar, Vladimir; Linhart, Ales

    2015-01-01

    More than 50% of all end-stage renal disease (ESRD) patients die from cardiovascular complications. Among them, heart failure and pulmonary hypertension play a major role, and published studies document significantly higher mortality rates in patients with these two states. Arteriovenous fistulas (AVF) and arteriovenous grafts (AVG) are the preferred types of vascular access (VA). However, both AVF and AVG increase cardiac output and in turn could contribute to (the decompensation of) heart failure or pulmonary hypertension. No really safe access flow volume exists, and the ESRD patients' reactions to it vary considerably. We review the mechanisms involved in the cardiovascular consequences of increased cardiac output and available literary data. The link between access flow volume and increased mortality due to pulmonary hypertension or heart failure probably exists, but still has not been directly evidenced. Regular echocardiography is advisable especially in patients with symptoms or with high VA flow (>1,500 ml/min). © 2015 S. Karger AG, Basel.

  7. Primary haemochromatosis. Early detection of commitment myocardium through cardiac magnetic resonance

    International Nuclear Information System (INIS)

    Corbella, F.; Rivas, Carlos; Dragonetti, Laura; Eyheremendy, Eduardo; Calo, Claudia

    2009-01-01

    Primary haemochromatosis is the most common genetic disease of the West (1 in 300 to 400 people). Cardiac involvement during its early stages is not detected by imaging techniques.During this period potentially lethal arrhythmias can occur. Using cardiac magnetic resonance (CMR) with T2 star sequence it is possible an early detection of cardiac involvement as well as a risk stratification and a monitoring the progress of the therapy. [es

  8. Initial Efficacy of a Cardiac Rehabilitation Transition Program: Cardiac TRUST

    OpenAIRE

    Dolansky, Mary A.; Zullo, Melissa; Boxer, Rebecca; Moore, Shirley M.

    2011-01-01

    Patients recovering from cardiac events are increasingly using postacute care, such as home health care and skilled nursing facility services. The purpose of this pilot study was to test the initial efficacy, feasibility, and safety of a specially designed postacute care transitional rehabilitation intervention for cardiac patients. Cardiac Transitional Rehabilitation Using Self- Management Techniques (Cardiac TRUST) is a family-focused intervention that includes progressive low-intensity wal...

  9. Comprehensive cardiac rehabilitation

    DEFF Research Database (Denmark)

    Kruse, Marie; Hochstrasser, Stefan; Zwisler, Ann-Dorthe O

    2006-01-01

    OBJECTIVES: The costs of comprehensive cardiac rehabilitation are established and compared to the corresponding costs of usual care. The effect on health-related quality of life is analyzed. METHODS: An unprecedented and very detailed cost assessment was carried out, as no guidelines existed...... for the situation at hand. Due to challenging circumstances, the cost assessment turned out to be ex-post and top-down. RESULTS: Cost per treatment sequence is estimated to be approximately euro 976, whereas the incremental cost (compared with usual care) is approximately euro 682. The cost estimate is uncertain...... and may be as high as euro 1.877. CONCLUSIONS: Comprehensive cardiac rehabilitation is more costly than usual care, and the higher costs are not outweighed by a quality of life gain. Comprehensive cardiac rehabilitation is, therefore, not cost-effective....

  10. Magnetic resonance imaging of implantable cardiac rhythm devices at 3.0 tesla.

    Science.gov (United States)

    Gimbel, J Rod

    2008-07-01

    A relaxation of the prohibition of scanning cardiac rhythm device patients is underway, largely because of the growing experience of safe scanning events at 1.5T. Magnetic resonance imaging (MRI) at 3T is becoming more common and may pose a different risk profile and outcome of MRI of cardiac device patients. No restrictions were placed on pacemaker dependency, region scanned, device type, or manufacturer. Sixteen scans at 3T were performed with an electrophysiologist present on 14 patients with a variety of devices from various manufacturers. An "MRI-S" strategy was used. Multimodal monitoring was required. Device interrogation was performed prior to, immediately after, and 1-3 months after the MRI. For nonpacemaker-dependent device patients, attempts were made to turn all device features off (with OOO programming the goal) conceptually rendering the device "invisible." In pacemaker-dependent patients, the device was programmed to asynchronous mode at highest output for the duration of the scan with the goal of rendering the device conceptually "invulnerable" to MRI effects. The specific absorption rate (SAR) was limited to 2W/kg. All patients were successfully scanned. No arrhythmias were noted. No significant change in the programmed parameters, pacing thresholds, sensing, impedance, or battery parameters was noted. The insertable loop recorder (ILR) recorded prolonged artifactual asystole during MRI. One patient noted chest burning during the scan. Device patients may undergo carefully tailored 3T MRI scans when pre-MRI reprogramming of the device occurs in conjunction with extensive monitoring, supervision, and follow-up.

  11. A Hierarchical Multi-Output Nearest Neighbor Model for Multi-Output Dependence Learning

    OpenAIRE

    Morris, Richard G.; Martinez, Tony; Smith, Michael R.

    2014-01-01

    Multi-Output Dependence (MOD) learning is a generalization of standard classification problems that allows for multiple outputs that are dependent on each other. A primary issue that arises in the context of MOD learning is that for any given input pattern there can be multiple correct output patterns. This changes the learning task from function approximation to relation approximation. Previous algorithms do not consider this problem, and thus cannot be readily applied to MOD problems. To pe...

  12. Quantitative cardiac computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Thelen, M.; Dueber, C.; Wolff, P.; Erbel, R.; Hoffmann, T.

    1985-06-01

    The scope and limitations of quantitative cardiac CT have been evaluated in a series of experimental and clinical studies. The left ventricular muscle mass was estimated by computed tomography in 19 dogs (using volumetric methods, measurements in two axes and planes and reference volume). There was good correlation with anatomical findings. The enddiastolic volume of the left ventricle was estimated in 22 patients with cardiomyopathies; using angiography as a reference, CT led to systematic under-estimation. It is also shown that ECG-triggered magnetic resonance tomography results in improved visualisation and may be expected to improve measurements of cardiac morphology.

  13. Mechanisms of Cardiac Regeneration

    Science.gov (United States)

    Uygur, Aysu; Lee, Richard T.

    2016-01-01

    Adult humans fail to regenerate their hearts following injury, and this failure to regenerate myocardium is a leading cause of heart failure and death worldwide. Although all adult mammals appear to lack significant cardiac regeneration potential, some vertebrates can regenerate myocardium throughout life. In addition, new studies indicate that mammals have cardiac regeneration potential during development and very soon after birth. The mechanisms of heart regeneration among model organisms, including neonatal mice, appear remarkably similar. Orchestrated waves of inflammation, matrix deposition and remodeling, and cardiomyocyte proliferation are commonly seen in heart regeneration models. Understanding why adult mammals develop extensive scarring instead of regeneration is a crucial goal for regenerative biology. PMID:26906733

  14. Impact of extracorporeal blood flow rate on blood pressure, pulse rate and cardiac output during haemodialysis

    DEFF Research Database (Denmark)

    Schytz, Philip Andreas; Mace, Maria Lerche; Soja, Anne Merete Boas

    2015-01-01

    BACKGROUND: If blood pressure (BP) falls during haemodialysis (HD) [intradialytic hypotension (IDH)] a common clinical practice is to reduce the extracorporeal blood flow rate (EBFR). Consequently the efficacy of the HD (Kt/V) is reduced. However, only very limited knowledge on the effect......, respectively. RESULTS: Mean (SD) age was 71 (11) years. Systolic BP was significantly higher at an EBFR of 200 mL/min as compared with 300 mL/min [133 (23) versus 128 (24) mmHg; P ...L/min diastolic BP, mean arterial pressure, PR and CO remained unchanged. CONCLUSION: Our study does not show any consistent trend in BP changes by a reduction in EBFR. Reduction in EBFR if BP falls during IDH is thus not supported. However, none of the patients experienced IDH. Further studies are required...

  15. Mechanisms of increase in cardiac output during acute weightlessness in humans

    DEFF Research Database (Denmark)

    Petersen, Lonnie G; Damgaard, Morten; Petersen, Johan Casper Grove

    2011-01-01

    by parabolic flight increased CO by 1.7 ± 0.4 l/min (P ... in CO during acute 0 G in seated humans. A Bainbridge-like reflex could be the mechanism for the HR-induced increase in CO during 0 G in particular in supine subjects....

  16. Evaluation of cerebral electrical activity and cardiac output after patent ductus arteriosus ligation in preterm infants.

    LENUS (Irish Health Repository)

    Leslie, A T F S

    2013-11-01

    To characterize and investigate the relationship between systemic blood flow and pre- and postoperative cerebral electrical activity in preterm neonates undergoing patent ductus arteriosus (PDA) ligation.

  17. Assessment of cardiac output with transpulmonary thermodilution during exercise in humans

    DEFF Research Database (Denmark)

    Calbet, José A L; Boushel, Robert

    2015-01-01

    and intrathoracic blood volume, as well as extravascular lung water (EVLW) in resting humans. It remains unknown if this technique is also accurate and reproducible during exercise. Sixteen healthy men underwent catheterization of the right femoral vein (for iced saline injection), an antecubital vein (ICG...

  18. Problems in Modelling Charge Output Accelerometers

    Directory of Open Access Journals (Sweden)

    Tomczyk Krzysztof

    2016-12-01

    Full Text Available The paper presents major issues associated with the problem of modelling change output accelerometers. The presented solutions are based on the weighted least squares (WLS method using transformation of the complex frequency response of the sensors. The main assumptions of the WLS method and a mathematical model of charge output accelerometers are presented in first two sections of this paper. In the next sections applying the WLS method to estimation of the accelerometer model parameters is discussed and the associated uncertainties are determined. Finally, the results of modelling a PCB357B73 charge output accelerometer are analysed in the last section of this paper. All calculations were executed using the MathCad software program. The main stages of these calculations are presented in Appendices A−E.

  19. Evidence for increased cardiac compliance during exposure to simulated microgravity.

    Science.gov (United States)

    Koenig, S C; Convertino, V A; Fanton, J W; Reister, C A; Gaffney, F A; Ludwig, D A; Krotov, V P; Trambovetsky, E V; Latham, R D

    1998-10-01

    We measured hemodynamic responses during 4 days of head-down tilt (HDT) and during graded lower body negative pressure (LBNP) in invasively instrumented rhesus monkeys to test the hypotheses that exposure to simulated microgravity increases cardiac compliance and that decreased stroke volume, cardiac output, and orthostatic tolerance are associated with reduced left ventricular peak dP/dt. Six monkeys underwent two 4-day (96 h) experimental conditions separated by 9 days of ambulatory activities in a crossover counterbalance design: 1) continuous exposure to 10 degrees HDT and 2) approximately 12-14 h per day of 80 degrees head-up tilt and 10-12 h supine (control condition). Each animal underwent measurements of central venous pressure (CVP), left ventricular and aortic pressures, stroke volume, esophageal pressure (EsP), plasma volume, alpha1- and beta1-adrenergic responsiveness, and tolerance to LBNP. HDT induced a hypovolemic and hypoadrenergic state with reduced LBNP tolerance compared with the control condition. Decreased LBNP tolerance with HDT was associated with reduced stroke volume, cardiac output, and peak dP/dt. Compared with the control condition, a 34% reduction in CVP (P = 0.010) and no change in left ventricular end-diastolic area during HDT was associated with increased ventricular compliance (P = 0.0053). Increased cardiac compliance could not be explained by reduced intrathoracic pressure since EsP was unaltered by HDT. Our data provide the first direct evidence that increased cardiac compliance was associated with headward fluid shifts similar to those induced by exposure to spaceflight and that reduced orthostatic tolerance was associated with lower cardiac contractility.

  20. The light output of BGO crystals

    International Nuclear Information System (INIS)

    Gong Zhufang; Ma Wengan; Lin Zhirong; Wang Zhaomin; Xu Zhizong; Fan Yangmei

    1987-01-01

    The dependence of light output on the surface treatment of BGO crystals has been tested. The results of experiments and Monte Carlo calculation indicate that for a tapered BGO crystal the best way to improve the uniformity and the energy resolution and to obtain higher light output is roughing the surface coupled to photomultiplier tube. The authors also observed that different wrapping method can effect its uniformity and resolutoin. Monte Carlo calculation indicates that the higher one of the 'double peaks' is the photoelectron peak of γ rays