Sample records for cardiac output monitoring

  1. Lack of agreement and trending ability of the endotracheal cardiac output monitor compared with thermodilution

    DEFF Research Database (Denmark)

    Møller-Sørensen, H; Hansen, K L; Ostergaard, M

    2012-01-01

    BACKGROUND: Minimally invasive monitoring systems of central haemodynamics are gaining increasing popularity. The present study investigated the precision of the endotracheal cardiac output monitor (ECOM) system and its agreement with pulmonary artery catheter thermodilution (PAC TD) for measuring...

  2. Non-invasive cardiac output monitoring in neonates using bioreactance: a comparison with echocardiography.

    LENUS (Irish Health Repository)

    Weisz, Dany E

    2012-01-01

    Non-invasive cardiac output monitoring is a potentially useful clinical tool in the neonatal setting. Our aim was to evaluate a new method of non-invasive continuous cardiac output (CO) measurement (NICOM™) based on the principle of bioreactance in neonates.

  3. Clinical Validation of Non-Invasive Cardiac Output Monitoring in Healthy Pregnant Women.

    Science.gov (United States)

    McLaughlin, Kelsey; Wright, Stephen P; Kingdom, John C P; Parker, John D

    2017-11-01

    Non-invasive hemodynamic monitoring has the potential to be a valuable clinical tool for the screening and management of hypertensive disorders of pregnancy. The objective of this study was to validate the clinical utility of the non-invasive cardiac output monitoring (NICOM) system in pregnant women. Twenty healthy pregnant women with a singleton pregnancy at 22 to 26 weeks' gestation were enrolled in this study. Measures of heart rate, stroke volume, and cardiac output were obtained through NICOM and compared with Doppler echocardiography. NICOM significantly overestimated measures of both stroke volume and cardiac output compared with Doppler echocardiography (95 ± 4 vs. 73 ± 4 mL, P gold standard for the measurement of cardiac output in the setting of pregnancy. However, once normal values have been established, NICOM has the potential to be a useful clinical tool for monitoring maternal hemodynamics in pregnant women. Further investigation regarding the validity of NICOM is required in larger populations of healthy and hypertensive pregnant women to determine whether this device is appropriate for maternal hemodynamic assessment during pregnancy. Copyright © 2017 The Society of Obstetricians and Gynaecologists of Canada/La Société des obstétriciens et gynécologues du Canada. Published by Elsevier Inc. All rights reserved.

  4. Estimating changes in cardiac output using an implanted hemodynamic monitor in heart failure patients

    DEFF Research Database (Denmark)

    Ståhlberg, Marcus; Damgaard, Morten; Ersgård, David

    2010-01-01

    OBJECTIVES: The aim of this study was to evaluate an algorithm that estimates changes in cardiac output (CO) from right ventricular (RV) pressure waveforms derived from an implantable hemodynamic monitor (IHM) in heart failure patients. DESIGN: Twelve heart failure patients (NYHA II-III, EF 32......%) with an implantable hemodynamic monitor (Chronicle) were included in this study. Changes in cardiac output were provoked by body position change at rest (left lateral supine, horizontal supine, sitting, and standing) and a steady state bicycle exercise at 20 watts. Estimated CO derived from the IHM (CO...... was -0.39 L/min (11%). Limits of agreement were +/-1.56 L/min and relative error was 21%. CONCLUSIONS: A simple algorithm based on RV pressure wave form characteristics derived from an IHM can be used to estimate changes in CO in heart failure patients. These findings encourage further research aiming...

  5. Cardiac output measurement

    Directory of Open Access Journals (Sweden)

    Andreja Möller Petrun

    2014-02-01

    Full Text Available In recent years, developments in the measuring of cardiac output and other haemodynamic variables are focused on the so-called minimally invasive methods. The aim of these methods is to simplify the management of high-risk and haemodynamically unstable patients. Due to the need of invasive approach and the possibility of serious complications the use of pulmonary artery catheter has decreased. This article describes the methods for measuring cardiac output, which are based on volume measurement (Fick method, indicator dilution method, pulse wave analysis, Doppler effect, and electrical bioimpedance.

  6. A-V Delay Versus Cardiac Output Measured with Thorax Bioimpedance Monitor

    Czech Academy of Sciences Publication Activity Database

    Vondra, Vlastimil; Halámek, Josef; Viščor, Ivo; Jurák, Pavel; Novák, M.; Lipoldová, J.

    2008-01-01

    Roč. 6, č. 1 (2008), s. 73 ISSN 1556-7451. [World Congress on Heart Disease /14./. 26.07.2008-29.07.2008, Toronto] Institutional research plan: CEZ:AV0Z20650511 Keywords : atrio-ventricular delay * resynchronization therapy * impedance cardiography * cardiac output Subject RIV: FA - Cardiovascular Disease s incl. Cardiotharic Surgery

  7. Fluid challenge: tracking changes in cardiac output with blood pressure monitoring (invasive or non-invasive).

    Science.gov (United States)

    Lakhal, Karim; Ehrmann, Stephan; Perrotin, Dominique; Wolff, Michel; Boulain, Thierry

    2013-11-01

    To assess whether invasive and non-invasive blood pressure (BP) monitoring allows the identification of patients who have responded to a fluid challenge, i.e., who have increased their cardiac output (CO). Patients with signs of circulatory failure were prospectively included. Before and after a fluid challenge, CO and the mean of four intra-arterial and oscillometric brachial cuff BP measurements were collected. Fluid responsiveness was defined by an increase in CO ≥10 or ≥15% in case of regular rhythm or arrhythmia, respectively. In 130 patients, the correlation between a fluid-induced increase in pulse pressure (Δ500mlPP) and fluid-induced increase in CO was weak and was similar for invasive and non-invasive measurements of BP: r² = 0.31 and r² = 0.29, respectively (both p area under the receiver-operating curve (AUC) of 0.82 (0.74-0.88), similar (p = 0.80) to that of non-invasive Δ500mlPP [AUC of 0.81 (0.73-0.87)]. Outside large gray zones of inconclusive values (5-23% for invasive Δ500mlPP and 4-35% for non-invasive Δ500mlPP, involving 35 and 48% of patients, respectively), the detection of responsiveness or unresponsiveness to fluid was reliable. Cardiac arrhythmia did not impair the performance of invasive or non-invasive Δ500mlPP. Other BP-derived indices did not outperform Δ500mlPP. As evidenced by large gray zones, BP-derived indices poorly reflected fluid responsiveness. However, in our deeply sedated population, a high increase in invasive pulse pressure (>23%) or even in non-invasive pulse pressure (>35%) reliably detected a response to fluid. In the absence of a marked increase in pulse pressure (<4-5%), a response to fluid was unlikely.

  8. Cardiac output during exercise

    DEFF Research Database (Denmark)

    Siebenmann, C; Rasmussen, P.; Sørensen, H.

    2015-01-01

    Several techniques assessing cardiac output (Q) during exercise are available. The extent to which the measurements obtained from each respective technique compares to one another, however, is unclear. We quantified Q simultaneously using four methods: the Fick method with blood obtained from...... the right atrium (Q(Fick-M)), Innocor (inert gas rebreathing; Q(Inn)), Physioflow (impedance cardiography; Q(Phys)), and Nexfin (pulse contour analysis; Q(Pulse)) in 12 male subjects during incremental cycling exercise to exhaustion in normoxia and hypoxia (FiO2  = 12%). While all four methods reported...... a progressive increase in Q with exercise intensity, the slopes of the Q/oxygen uptake (VO2) relationship differed by up to 50% between methods in both normoxia [4.9 ± 0.3, 3.9 ± 0.2, 6.0 ± 0.4, 4.8 ± 0.2 L/min per L/min (mean ± SE) for Q(Fick-M), Q(Inn), QP hys and Q(Pulse), respectively; P = 0...

  9. The use of cardiac output monitoring to guide the administration of intravenous fluid during hyperthermic intraperitoneal chemotherapy.

    Science.gov (United States)

    Thanigaimani, K; Mohamed, F; Cecil, T; Moran, B J; Bell, J

    2013-12-01

    The optimal strategy for intravenous (IV) fluid management during administration of hyperthermic intraperitoneal chemotherapy (HIPEC) is unclear. In this prospective study we describe the use of a LiDCOrapid™ (LiDCO, Cambridge, UK) cardiac output monitor to guide IV fluid management during cytoreductive surgery (CRS) with HIPEC. The aim of this study was to determine whether cardiac output monitoring will allow close maintenance of physiological parameters during the HIPEC phase. Twenty-five patients who underwent CRS combined with HIPEC were included in the study. Intra-operative IV fluid boluses were titrated using parameters measured by the LiDCOrapid™ monitor. Stroke volume variation was maintained below 10% with fluid boluses and mean arterial pressure was maintained within 20% of the baseline figure with vasopressors. There was no significant change in heart rate and cardiac output. The systemic vascular resistance dropped from an average of 966 dyn.s/cm-5 to 797 dyn s/cm(5) at 60 min during the HIPEC phase (P = 0.62) despite an increase in the dose of phenylepherine. The average total volume of fluid given was 748 ml in the first 30 min and 630 ml in the second 30 min with an average urine output of 307 and 445 ml, respectively. The change in lactate levels was not statistically or clinically significant. LiDCOrapid™ is an effective noninvasive tool for guiding fluid management in this population. It allows the anaesthesiologist to maintain tight control of essential physiological parameters during a phase of the procedure in which there is a risk of renal injury. Colorectal Disease © 2013 The Association of Coloproctology of Great Britain and Ireland.

  10. Monitoring cardiac output during hyperbaric oxygen treatment of haemodynamically unstable patients

    DEFF Research Database (Denmark)

    Hansen, Marco Bo; Treschow, Frederik; Skielboe, Martin

    2013-01-01

    Patients suffering from necrotizing fasciitis (NF) are often haemodynamically unstable and require extended monitoring of cardiovascular parameters; yet this is limited during hyperbaric oxygen treatment (HBOT). We aimed to evaluate the use and safety of transoesophageal Doppler (TED) monitoring ...

  11. [Effects of application of pulse contour cardiac output monitoring technology in early treatment of patients with large area burns].

    Science.gov (United States)

    Wang, D Y; Xie, W G; Xi, M M; Li, Z; Wang, B

    2018-01-20

    Objective: To analyze the changes and relationship of early hemodynamic indexes of patients with large area burns monitored by pulse contour cardiac output (PiCCO) monitoring technology, so as to assess the guiding value of this technology in the treatment of patients with large area burns during shock period. Methods: Eighteen patients with large area burns, confirming to the study criteria, were admitted to our unit from May 2016 to May 2017. Pulse contour cardiac output index (PCCI), systemic vascular resistance index (SVRI), global end-diastolic volume index (GEDVI), and extravascular lung water index (EVLWI) of patients were monitored by PiCCO instrument from admission to post injury day (PID) 7, and they were calibrated and recorded once every four hours. The fluid infusion coefficients of patients at the first and second 24 hours post injury were calculated. The blood lactic acid values of patients from PID 1 to 7 were also recorded. The correlations among PCCI, SVRI, and GEDVI as well as the correlation between SVRI and blood lactic acid of these 18 patients were analyzed. Prognosis of patients were recorded. Data were processed with one-way analysis of variance, single sample t test and Bonferroni correction, Pearson correlation analysis, and Spearman rank correlation analysis. Results: (1) There was statistically significant difference in PCCI value of patients from post injury hour (PIH) 4 to 168 ( F =7.428, P 0.05). (2) There was statistically significant difference in SVRI value of patients from PIH 4 to 168 ( F =7.863, P 0.05). (3) There was no statistically significant difference in the GEDVI values of patients from PIH 4 to 168 ( F =0.704, P >0.05). The GEDVI values of patients at PIH 8, 12, 16, 20, and 24 were significantly lower than normal value ( t =-3.112, -3.554, -2.969, -2.450, -2.476, P 0.05). (4) There was statistically significant difference in EVLWI value of patients from PIH 4 to 168 ( F =1.859, P 0.05). (5) The fluid infusion

  12. Electrical Cardiometry to Monitor Cardiac Output in Preterm Infants with Patent Ductus Arteriosus: A Comparison with Echocardiography.

    Science.gov (United States)

    Hsu, Kai-Hsiang; Wu, Tai-Wei; Wu, I-Hsyuan; Lai, Mei-Yin; Hsu, Shih-Yun; Huang, Hsiao-Wen; Mok, Tze-Yee; Lien, Reyin

    2017-01-01

    Electrical cardiometry (EC) is an impedance-based monitoring that provides noninvasive cardiac output (CO) assessment. Through comparison to transthoracic echocardiography (Echo), the accuracy of EC has been verified. However, left-to-right patent ductus arteriosus (PDA) shunting is a concern because PDA shunts aortic flow to the pulmonary artery and may interfere with EC in measuring CO. To determine the agreement between EC and Echo in preterm infants with a hemodynamically significant PDA (hsPDA). We reviewed our hemodynamic database in which simultaneous CO measurements by Echo and EC (Aesculon®) were recorded. Preterm infants with left-to-right shunting hsPDA were enrolled. A total of 105 paired measurements in 36 preterm infants were compared. Infants' median (range) age and weight at measurement were 27+2 weeks (24+0-33+1) and 1,015 g (518-1,880), with mean (95% CI) ductal diameter 2.11 mm (1.99-2.22) or 2.15 mm/kg (2.00-2.30). Mean COEC and COEcho were 252 ± 32 and 258 ± 45 mL/kg/min, respectively, which demonstrated a moderate correlation and without a significant between-measurement difference. Bland-Altman analysis showed a bias, limits of agreement, and error percentage of -5.3 mL/kg/min, -78.3 to 67.7 mL/kg/min, and 28.6%, respectively. There was a trend of increased bias and error percentage of infants with high CO ≥280 mL/kg/min and supported with high-frequency ventilator. EC and Echo have a wide but clinically acceptable agreement in measuring CO in preterm infants with hsPDA. However, for infants with high CO or ventilated by high-frequency ventilation, interpretation of COEC should be approached with caution. © 2017 S. Karger AG, Basel.

  13. Comparing Methods for Cardiac Output

    DEFF Research Database (Denmark)

    Graeser, Karin; Zemtsovski, Mikhail; Kofoed, Klaus F

    2018-01-01

    of the left ventricular outflow tract. METHODS: The primary aim was a systematic comparison of CO with Doppler-derived 3D TEE and CO by thermodilution in a broad population of patients undergoing cardiac surgery. A subanalysis was performed comparing cross-sectional area by TEE with cardiac computed...... tomography (CT) angiography. Sixty-two patients, scheduled for elective heart surgery, were included; 1 was subsequently excluded for logistic reasons. Inclusion criteria were coronary artery bypass surgery (N = 42) and aortic valve replacement (N = 19). Exclusion criteria were chronic atrial fibrillation......, left ventricular ejection fraction below 0.40 and intracardiac shunts. Nineteen randomly selected patients had a cardiac CT the day before surgery. All images were stored for blinded post hoc analyses, and Bland-Altman plots were used to assess agreement between measurement methods, defined as the bias...

  14. Comparison of cardiac output measurement techniques

    DEFF Research Database (Denmark)

    Espersen, K; Jensen, E W; Rosenborg, D

    1995-01-01

    Simultaneously measured cardiac output obtained by thermodilution (TD), transcutaneous suprasternal ultrasonic Doppler (DOP), CO2-rebreathing (CR) and the direct Fick method (FI) were compared in eleven healthy subjects in a supine position (SU), a sitting position (SI), and during sitting exercise...

  15. Cardiac output measurement instruments controlled by microprocessors

    International Nuclear Information System (INIS)

    Spector, M.; Barritault, L.; Boeri, C.; Fauchet, M.; Gambini, D.; Vernejoul, P. de

    The nuclear medicine and biophysics laboratory of the Necker-Enfants malades University Hospital Centre has built a microprocessor controlled Cardiac flowmetre. The principle of the cardiac output measurement from a radiocardiogram is well established. After injection of a radioactive indicator upstream from the heart cavities the dilution curve is obtained by the use of a gamma-ray precordial detector. This curve normally displays two peaks due to passage of the indicator into the right and left sides of the heart respectively. The output is then obtained from the stewart Hamilton principle once recirculation is eliminated. The graphic method used for the calculation however is long and tedious. The decreasing fraction of the dilution curve is projected in logarithmic space in order to eliminate recirculation by determining the mean straight line from which the decreasing exponential is obtained. The principle of the use of microprocessors is explained (electronics, logics) [fr

  16. Peripheral vasodilatation determines cardiac output in exercising humans

    DEFF Research Database (Denmark)

    Bada, A A; Svendsen, J H; Secher, N H

    2012-01-01

    In dogs, manipulation of heart rate has no effect on the exercise-induced increase in cardiac output. Whether these findings apply to humans remain uncertain, because of the large differences in cardiovascular anatomy and regulation. To investigate the role of heart rate and peripheral...... arterial ATP infusion at rest. Exercise and ATP infusion increased cardiac output, leg blood flow and vascular conductance (P heart rate by up to 54 beats min(−1), cardiac output did not change in any of the three...... demonstrate that the elevated cardiac output during steady-state exercise is regulated by the increase in skeletal muscle blood flow and venous return to the heart, whereas the increase in heart rate appears to be secondary to the regulation of cardiac output....

  17. EVALUATION OF CONTINUOUS THERMODILUTION METHOD FOR CARDIAC OUTPUT MEASUREMENT

    Directory of Open Access Journals (Sweden)

    Roman Parežnik

    2001-12-01

    Full Text Available Background. Continuous monitoring of haemodynamic variables is often necessary for detection of rapid changes in critically ill patients. In our patients recently introduced continuous thermodilution technique (CTD for cardiac output measurement was compared to bolus thermodilution technique (BTD which is a »golden standard« method for cardiac output (CO measurement in intensive care medicine.Methods. Ten critically ill patients were included in a retrospective observational study. Using CTD method cardiac output was measured continuously. BTD measurements using the same equipment were performed intermittently. The data obtained by BTD were compared to those obtained by CTD just before the BTD (CTD-before and 2–3 minutes after the BTD (CTD-after. The CO values were divided into three groups: all CO values, CO > 4.5 L/min, CO < 4.5 L/min. The bias (mean difference between values obtained by two methods, standard deviation, 95% confidence limits and relative error were calculated and the linear regression analysis was performed. t-test for pared data was used to compare the biases for CTD-before and CTD-after for an individual group. The p value of less than 0.05 was considered statistically significant.Results. A total of 60 data triplets were obtained. CTD-before ranged from 1.9 L/min to 12.6 L/min, CTD-after from 2.0 to 13.2 L/min and BTD from 1.9 to 12.0 L/min. For all CO values the bias for CTD-before was 0.13 ± 0.52 L/min (95% confidence limits 1.17–0.91 L/min, relative error was 3.52 ± 15.20%, linear regression equation was CTD-before = 0.96 × BTD + 0.01 and Pearson’s correlation coefficient was 0.95. The values for CTD-after were 0.08 ± 0.46 L/min (1.0–0.84 L/min, 2.22 ± 9.05%, CTD-after = 0.98 × BTD + 0.01 and 0.98 respectively. For all CO values there was no statistically significant difference between biases for CTD-before and CTD-after (p = 0,51. There was no statistically significant difference between biases for CTD

  18. Measurement of cardiac output in man with MR imaging

    International Nuclear Information System (INIS)

    Lipton, M.J.; Weikl, A.; Mueller, E.; Reinhardt, E.R.

    1987-01-01

    Multiecho electrocardiogram-triggered imaging sequences were obtained in 15 patients to measure aortic blood flow velocity in a 6-cm thick section. The aortic area was calculated from MR images; cardiac output was calculated as the product of velocity and area and was expressed in liters per minute. MR imaging results were compared with measurements obtained by cardiac catheterization and thermodilution. A good correlation of 0.9 was found, with a slope approaching unity

  19. Relationship between cardiac output and effective renal plasma flow in patients with cardiac disease

    Energy Technology Data Exchange (ETDEWEB)

    McGriffin, D; Tauxe, W N; Lewis, C; Karp, R; Mantle, J

    1984-12-01

    The relationship between effective renal plasma flow (ERPF) and cardiac output was examined in 46 patients (22 with congestive heart failure and 24 following cardiac surgical procedures) by simultaneously measuring the global ERPF by the single-injection method and cardiac output by the thermodilution method. Of the patients in the heart-failure group, 21 also had pulmonary artery end diastolic pressure (PAEDP) recorded at the same time. ERPF and cardiac output were found to be related by the regression equations: cardiac output = 2.08 + 0.0065 ERPF (r, 080), with a SE of estimate of 0.81 l/min. ERPF and PAEDP were related by the regression equation: PAEDP = 42.02 - 0.0675 ERPF (r, 0.86), with a SE of estimate of 5.5 mm Hg. ERPF may be a useful noninvasive method of estimating cardiac output if it is known that no intrinsic kidney disease is present, and if the error of 0.81 l/min (1 SE of estimate) is within the range of clinical usefulness. The error is principally attributable to the determination of cardiac output by the thermodilution method.

  20. Measurement of Cardiac Output by Constant Injection of Radioactive Xenon

    Energy Technology Data Exchange (ETDEWEB)

    Kishon, Y.; Avasthey, P.; Barnett, A.; Shillingford, J. P. [MRC Cardiovascular Research Unit and Department of Medicine, Royal Postgraduate Medical School, Hammersmith Hospital, London (United Kingdom)

    1971-02-15

    The method of determining cardiac output by the injection of {sup 133}Xe solution has been initially tested in a suitable hydrodynamic model, simulating the cardiovascular system. The indicator was infused in a constant rate into a ''pre-ventricular'' site through a fine polyethylene tubing, and samples were taken from a ''post-ventricular'' site through similar tubing. Specific activity was determined with the use of a universal well-type scintillation counter and output values were derived from the dilutional factor of the specific activity and the rate of the infusion. Good correlation with direct output measurements were demonstrated over a wide range of outputs, stroke volumes and end-diastolic volumes. The method remained valid when either the ''pre-ventricular'' or the ''post-ventricular'' valve was made incompetent. The method was then evaluated in anaesthetized dogs and cardiac output determinations were compared with those obtained by the Fick and dye-dilution techniques. The indicator was injected into the right atrium, and samples were obtained from the pulmonary artery through similar tubings. The method was found to be reliable over a wide range of cardiac outputs (drugs- and bleeding-induced) and in the presence of severe tricuspid incompetence (performed by a valvotome). Finally, the technique was used in six patients, both at rest and after exercise, and the cardiac output values were compared with those obtained by the Fick and the photoelectric-earpiece dye-dilution techniques. It is concluded that, provided the appropriate speed of injection (about 1.5 - 3.5 {mu}Ci/sec) and the time of sampling is carefully observed, good correlation between the method under investigation and other conventional methods could be shown. This method is more convenient for repeated determinations, simpler to perform and final values are obtained almost immediately. (author)

  1. Comparing Methods for Cardiac Output: Intraoperatively Doppler-Derived Cardiac Output Measured With 3-Dimensional Echocardiography Is Not Interchangeable With Cardiac Output by Pulmonary Catheter Thermodilution.

    Science.gov (United States)

    Graeser, Karin; Zemtsovski, Mikhail; Kofoed, Klaus F; Winther-Jensen, Matilde; Nilsson, Jens C; Kjaergaard, Jesper; Møller-Sørensen, Hasse

    2018-01-09

    Estimation of cardiac output (CO) is essential in the treatment of circulatory unstable patients. CO measured by pulmonary artery catheter thermodilution is considered the gold standard but carries a small risk of severe complications. Stroke volume and CO can be measured by transesophageal echocardiography (TEE), which is widely used during cardiac surgery. We hypothesized that Doppler-derived CO by 3-dimensional (3D) TEE would agree well with CO measured with pulmonary artery catheter thermodilution as a reference method based on accurate measurements of the cross-sectional area of the left ventricular outflow tract. The primary aim was a systematic comparison of CO with Doppler-derived 3D TEE and CO by thermodilution in a broad population of patients undergoing cardiac surgery. A subanalysis was performed comparing cross-sectional area by TEE with cardiac computed tomography (CT) angiography. Sixty-two patients, scheduled for elective heart surgery, were included; 1 was subsequently excluded for logistic reasons. Inclusion criteria were coronary artery bypass surgery (N = 42) and aortic valve replacement (N = 19). Exclusion criteria were chronic atrial fibrillation, left ventricular ejection fraction below 0.40 and intracardiac shunts. Nineteen randomly selected patients had a cardiac CT the day before surgery. All images were stored for blinded post hoc analyses, and Bland-Altman plots were used to assess agreement between measurement methods, defined as the bias (mean difference between methods), limits of agreement (equal to bias ± 2 standard deviations of the bias), and percentage error (limits of agreement divided by the mean of the 2 methods). Precision was determined for the individual methods (equal to 2 standard deviations of the bias between replicate measurements) to determine the acceptable limits of agreement. We found a good precision for Doppler-derived CO measured by 3D TEE, but although the bias for Doppler-derived CO by 3D compared to

  2. Constant infusion transpulmonary thermodilution for the assessment of cardiac output in exercising humans

    DEFF Research Database (Denmark)

    Calbet, J A L; Mortensen, Stefan; Munch, G D W

    2016-01-01

    To determine the accuracy and precision of constant infusion transpulmonary thermodilution cardiac output (CITT-Q) assessment during exercise in humans, using indocyanine green (ICG) dilution and bolus transpulmonary thermodilution (BTD) as reference methods, cardiac output (Q) was determined......: 6.1-11.1%). In conclusion, cardiac output can be precisely and accurately determined with constant infusion transpulmonary thermodilution in exercising humans....

  3. Impedance cardiography: a comparison of cardiac output vs waveform analysis for assessing left ventricular systolic dysfunction.

    Science.gov (United States)

    DeMarzo, Arthur P; Kelly, Russell F; Calvin, James E

    2007-01-01

    Early detection of asymptomatic left ventricular systolic dysfunction (LVSD) is beneficial in managing heart failure. Recent studies have cast doubt on the usefulness of cardiac output as an indicator of LVSD. In impedance cardiography (ICG), the dZ/dt waveform has a systolic wave called the E wave. This study looked at measurements of the amplitude and area of the E wave compared with ICG-derived cardiac output, stroke volume, cardiac index, and stroke index as methods of assessing LVSD. ICG data were obtained from patients (n=26) admitted to a coronary care unit. Clinical LVSD severity was stratified into 4 groups (none, mild, moderate, and severe) based on echocardiography data and standard clinical assessment by a cardiologist blinded to ICG data. Statistical analysis showed that the E wave amplitude and area were better indicators of the level of LVSD than cardiac output, stroke volume, cardiac index, or stroke index. ICG waveform analysis has potential as a simple point-of-care test for detecting LVSD in asymptomatic patients at high risk for developing heart failure and for monitoring LVSD in patients being treated for heart failure.

  4. Changes in cardiac output and incidence of volume overload in cirrhotics receiving 20% albumin infusion.

    Science.gov (United States)

    Shasthry, Saggere M; Kumar, Manoj; Khumuckham, Jelen S; Sarin, Shiv Kumar

    2017-08-01

    Patients with cirrhosis are prone to develop volume over load, have increased capillary permeability and latent or overt cardiomyopathy. Whether albumin infusion causes volume overload in cirrhotics has not been adequately studied. Ninety nine consecutive cirrhotic patients receiving 1gm per kg albumin infusion were evaluated for development of volume overload. Clinical, echocardiographic and haemodynamic changes were closely monitored during and after albumin infusion. Thirty (30.30%) patients developed volume overload. Patients with higher BMI (P=.003), lower CTP (P=.01) and MELD (P=.034) were more often associated with the development of volume overload. Though baseline diastolic dysfunction was present in 82.8% of the patients, it did not influence the development of volume overload or changes in the cardiac output. The cardiac output increased significantly after albumin infusion (4.9±1.554 L/min to 5.86±1.85 L/min, Palbumin infusion develop volume overload, specially, those with higher BMI and lower severity of liver disease. Cardiac output increases after albumin infusion, and, baseline diastolic dysfunction has little effect on the development of volume overload or changes in cardiac output. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Systematic review of cardiac output measurements by echocardiography vs. thermodilution

    DEFF Research Database (Denmark)

    Wetterslev, Mik; Møller-Sørensen, Hasse; Johansen, Rasmus Rothmann

    2016-01-01

    PURPOSE: Echocardiography is frequently used in the hemodynamic evaluation of critically ill patients, but inaccurate measurements may lead to wrong clinical decisions. The aim of our systematic review was to investigate the interchangeability of echocardiography with thermodilution technique...... of the studies assessed left-sided heart structures and the majority had small bias, wide limits of agreement, and high percentage error between echocardiography and thermodilution. In only two of the 24 studies the precision of each technique (echocardiography and thermodilution) was assessed before comparing...... them. In the single study evaluating trending ability using valid methodology, agreement was observed between echocardiography and thermodilution in detecting the directional changes in cardiac output, but the magnitude of changes varied considerably. CONCLUSIONS: The majority of studies comparing...

  6. Cardiac output estimation using pulmonary mechanics in mechanically ventilated patients

    Directory of Open Access Journals (Sweden)

    Hann Christopher E

    2010-11-01

    Full Text Available Abstract The application of positive end expiratory pressure (PEEP in mechanically ventilated (MV patients with acute respiratory distress syndrome (ARDS decreases cardiac output (CO. Accurate measurement of CO is highly invasive and is not ideal for all MV critically ill patients. However, the link between the PEEP used in MV, and CO provides an opportunity to assess CO via MV therapy and other existing measurements, creating a CO measure without further invasiveness. This paper examines combining models of diffusion resistance and lung mechanics, to help predict CO changes due to PEEP. The CO estimator uses an initial measurement of pulmonary shunt, and estimations of shunt changes due to PEEP to predict CO at different levels of PEEP. Inputs to the cardiac model are the PV loops from the ventilator, as well as the oxygen saturation values using known respiratory inspired oxygen content. The outputs are estimates of pulmonary shunt and CO changes due to changes in applied PEEP. Data from two published studies are used to assess and initially validate this model. The model shows the effect on oxygenation due to decreased CO and decreased shunt, resulting from increased PEEP. It concludes that there is a trade off on oxygenation parameters. More clinically importantly, the model also examines how the rate of CO drop with increased PEEP can be used as a method to determine optimal PEEP, which may be used to optimise MV therapy with respect to the gas exchange achieved, as well as accounting for the impact on the cardiovascular system and its management.

  7. Consenso brasileiro de monitorização e suporte hemodinâmico - parte III: métodos alternativos de monitorização do débito cardíaco e da volemia Brazilian consensus of monitoring and hemodynamic support - part III: alternative methods for cardiac output monitoring and volemia estimation

    Directory of Open Access Journals (Sweden)

    Guilherme Schettino

    2006-03-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: A interpretação do débito cardíaco e da pré-carga como números absolutos não traz grandes informações sobre a hemodinâmica do paciente crítico. Em contrapartida, a monitorização da resposta do débito cardíaco à expansão volêmica ou suporte inotrópico é uma ferramenta muito útil na unidade de terapia intensiva, quando o paciente apresenta algum sinal de má perfusão tecidual. Apesar do CAP ser considerado como " padrão-ouro" na avaliação destes parâmetros, foram desenvolvidas tecnologias alternativas bastante confiáveis para a sua monitorização. MÉTODO: O processo de desenvolvimento de recomendações utilizou o método Delphi modificado para criar e quantificar o consenso entre os participantes. A AMIB determinou um coordenador para o consenso, o qual escolheu seis especialistas para comporem o comitê consultivo. Outros 18 peritos de diferentes regiões do país foram selecionados para completar o painel de 25 especialistas, médicos e enfermeiros. Um levantamento bibliográfico na MEDLINE de artigos na língua inglesa foi realizado no período de 1966 a 2004. RESULTADOS: Foram apresentadas recomendações referentes à análise da variação da pressão arterial durante ventilação mecânica, débito cardíaco contínuo por contorno de pulso arterial, débito cardíaco por diluição do lítio, Doppler transesofágico, bioimpedância transtorácica, ecocardiografia e reinalação parcial de gás carbônico. CONCLUSÕES: As novas e menos invasivas técnicas para medida do débito cardíaco, pré-carga e fluidoresponsividade apresentam adequada precisão e podem ser uma alternativa ao uso do CAP em pacientes graves.BACKGROUND AND OBJECTIVES: Cardiac output and preload as absolute data do not offer helpful information about the hemodynamic of critically ill patients. However, monitoring the response of these variables to volume challenge or inotropic drugs is a very useful tool in the

  8. Cardiac output and regional blood flow following trauma

    International Nuclear Information System (INIS)

    Malik, A.B.; Loegering, D.J.; Saba, T.M.; Kaplan, J.E.

    1978-01-01

    The changes in cardiac output (2), regional blood blow (2r) and regional vascular resistance, and arterial pressure were studied in rats subjected to moderate (LD0) or severe (LD50) traumatic shock. 2 and 2r were determined using microspheres at 15, 60 and 180 min posttrauma. Arterial pressure decreased in both groups at 15 min and recovered by 3 h after sublethal (LD0) trauma, while arterial pressure did not return to control levels after LD50 trauma. 2 decreased in both groups at 15 min and returned to control only in the LD0 trauma group by 3 h. Cerebral, coronary, and hepatic arterial flows and resistances were maintained in both groups. Renal, intestinal, and splenic flows decreased and resistances were maintained in both groups. Renal, intestinal, and splenic flows decreased and resistances increased in both groups by 15 min and returned to control levels by 3 h only in the LD0 trauma group. Total hepatic and hepatic portal flows decreased at 60 min and returned to control levels at 3 h after LD0 trauma, while there was significant depression in these parameters 3 h after LD50 trauma. Therefore, sublethal and severe trauma resulted in early redistribution of flow favoring the coronary, cerebral, and hepatic arterial beds. However, renal, intestinal, splenic, and portal flows remained depressed only in severely traumatized rats, suggesting that continued hypofusion is a factor in the multiple organ failure and death following severe traumatic injury

  9. Simultaneous cardiac output and regional myocardial perfusion determination with PET and nitrogen 13 ammonia

    DEFF Research Database (Denmark)

    Hove, Jens D; Kofoed, Klaus F; Wu, Hsiao M

    2003-01-01

    The purpose of this study was to evaluate the possibility of measuring cardiac output during positron emission tomography (PET) examination of myocardial perfusion with nitrogen 13 ammonia.......The purpose of this study was to evaluate the possibility of measuring cardiac output during positron emission tomography (PET) examination of myocardial perfusion with nitrogen 13 ammonia....

  10. Kredsløbsmonitorering med lithium dilution cardiac output-systemet

    DEFF Research Database (Denmark)

    Christiansen, Christian; Hostrup, Anette; Tønnesen, Else

    2008-01-01

    The lithium dilution cardiac output (LiDCO) system measures cardiac output beat-to-beat with high precision. The system is based on an arterial pulse power analysis which is calibrated every eight hours with a small non-pharmacological dose of lithium. The system is minimally invasive; it requires...

  11. An update on insertable cardiac monitors

    DEFF Research Database (Denmark)

    Olsen, Flemming J; Biering-Sørensen, Tor; Krieger, Derk W

    2015-01-01

    Continuous cardiac rhythm monitoring has undergone compelling progress over the past decades. Cardiac monitoring has emerged from 12-lead electrocardiograms being performed at the discretion of the treating physician to in-hospital telemetry, Holter monitoring, prolonged external event monitoring...... turning point in the field of arrhythmia management. However, their role in the detection of paroxysmal atrial fibrillation after cryptogenic strokes has yet to evolve. This will be the main focus of this review. Issues surrounding patient selection, clinical relevance and determination of cost......-effectiveness for prolonged cardiac monitoring require further studies. Furthermore, insertable cardiac monitoring has not only the potential to augment diagnostic capabilities but also to improve the management of paroxysmal atrial fibrillation....

  12. Mechanisms Regulating the Cardiac Output Response to Cyanide Infusion, a Model of Hypoxia

    Science.gov (United States)

    Liang, Chang-seng; Huckabee, William E.

    1973-01-01

    When tissue metabolic changes like those of hypoxia were induced by intra-aortic infusion of cyanide in dogs, cardiac output began to increase after 3 to 5 min, reached a peak (220% of the control value) at 15 min, and returned to control in 40 min. This pattern of cardiac output rise was not altered by vagotomy with or without atropine pretreatment. However, this cardiac output response could be differentiated into three phases by pretreating the animals with agents that block specific activities of the sympatho-adrenal system. First, ganglionic blockade produced by mecamylamine or sympathetic nerve blockade by bretylium abolished the middle phase of the cardiac output seen in the untreated animal, but early and late phases still could be discerned. Second, beta-adrenergic receptor blockade produced by propranolol shortened the total duration of the cardiac output rise by abolishing the late phase. Third, when given together, propranolol and mecamylamine (or bretylium) prevented most of the cardiac output rise that follows the early phase. When cyanide was given to splenectomized dogs, the duration of the cardiac output response was not shortened, but the response became biphasic, resembling that seen after chemical sympathectomy. A similar biphasic response of the cardiac output also resulted from splenic denervation; sham operation or nephrectomy had no effect on the monophasic pattern of the normal response. Splenic venous blood obtained from cyanide-treated dogs, when infused intraportally, caused an increase in cardiac output in recipient dogs; similar infusion of arterial blood had no effects. These results suggest that the cardiac output response to cyanide infusion consists of three components: an early phase, related neither to the autonomic nervous system nor to circulating catecholamines; a middle phase, caused by a nonadrenergic humoral substance released from the spleen by sympathetic stimulation; and a late phase, dependent upon adrenergic receptors

  13. [Measurement of cardiac output by thermodilution with a diode as a temperature sensor].

    Science.gov (United States)

    Díaz Fernández, A; Benítez, D; Sánchez Tello, G; Márquez, L A

    1979-01-01

    An area integrator for the thermodilution curve in cardiac output measurement is described. A new temperature sensor is used, a diode with some advantages over the thermistor normally used. The main advantages are: easy calibration and replacement, and broad range of linearity. The cardiac output values obtained in dog with the integrator follow a linear relationship with those of the flowmeter. In simultaneous measurements the correlation is R = 0.96. Using a diode as temperature sensor a modification of the Steward Hamilton equation (used for thermistor) is necessary. With this new equation a monogram is performed to calculate the cardiac output from the area given by the numerical integrator.

  14. Comparison of dye dilution method to radionuclide techniques for cardiac output determination in dogs

    International Nuclear Information System (INIS)

    Eng, S.S.; Robayo, J.R.; Porter, W.; Smith, R.E.

    1980-01-01

    A study was undertaken to identify the most accurate /sup 99m/Tc-labeled radiopharmaceutical and to determine the accuracy of a noninvasive radionuclide technique or cardiac output determinations. Phase I employed sodium pertechnetate, stannous pyrophosphate with sodium pertechnetate, /sup 99m/Tc red blood cells, and /sup 99m/Tc human serum albumin as radionuclide tracers. Cardiac output was determined by the dye dilution method and then by the invasive radionuclide technique. A pairied t test and regression analysis indicated that /sup 99m/Tc human serum albumin was the most accurate radiopharmaceutical for cardiac output determinations, and the results compared favorably to those obtained by the dye dilution method. In Phase II, /sup 99m/Tc human serum albumin was used as the radionuclide tracer for cardiac output determinations with the noninvasive technique. The results compared favorably to those obtained by the dye dilution method

  15. High-output cardiac failure secondary to multiple vascular malformations in the liver: case report

    International Nuclear Information System (INIS)

    Spaner, S.; Demeter, S.; Lien, D.; Shapiro, J.; McCarthy, M.; Raymond, G.

    2001-01-01

    High-output cardiac failure is associated with several systemic illnesses, including hyperthyroidism, thiamine deficiency, severe anemia, multiple myeloma, Paget's disease of bone and Osler-Weber-Rendu syndrome. We present an unusual case of a woman with high-output cardiac failure as a result of multiple arteriovenous fistulas in the liver, most likely representing an unusual variant of Osler-Weber-Rendu syndrome (i.e., no other telangiectasias or a family history of vascular malformations was demonstrated). (author)

  16. Determination of myocardial energetic output for cardiac rhythm pacing

    Czech Academy of Sciences Publication Activity Database

    Heřman, D.; Převorovská, Světlana; Maršík, František

    2007-01-01

    Roč. 7, č. 4 (2007), s. 156-161 ISSN 1567-8822 R&D Projects: GA ČR GA106/03/1073 Institutional research plan: CEZ:AV0Z20760514 Keywords : heart arrhythmia * cardiac pacing modes * numerical simulation Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery

  17. Cerebral oxygen saturation and cardiac output during anaesthesia in sitting position for neurosurgical procedures: a prospective observational study.

    Science.gov (United States)

    Schramm, P; Tzanova, I; Hagen, F; Berres, M; Closhen, D; Pestel, G; Engelhard, K

    2016-10-01

    Neurosurgical operations in the dorsal cranium often require the patient to be positioned in a sitting position. This can be associated with decreased cardiac output and cerebral hypoperfusion, and possibly, inadequate cerebral oxygenation. In the present study, cerebral oxygen saturation was measured during neurosurgery in the sitting position and correlated with cardiac output. Perioperative cerebral oxygen saturation was measured continuously with two different monitors, INVOS ® and FORE-SIGHT ® . Cardiac output was measured at eight predefined time points using transoesophageal echocardiography. Forty patients were enrolled, but only 35 (20 female) were eventually operated on in the sitting position. At the first time point, the regional cerebral oxygen saturation measured with INVOS ® was 70 (sd 9)%; thereafter, it increased by 0.0187% min -1 (P<0.01). The cerebral tissue oxygen saturation measured with FORE-SIGHT ® started at 68 (sd 13)% and increased by 0.0142% min -1 (P<0.01). The mean arterial blood pressure did not change. Cardiac output was between 6.3 (sd 1.3) and 7.2 (1.8) litre min -1 at the predefined time points. Cardiac output, but not mean arterial blood pressure, showed a positive and significant correlation with cerebral oxygen saturation. During neurosurgery in the sitting position, the cerebral oxygen saturation slowly increases and, therefore, this position seems to be safe with regard to cerebral oxygen saturation. Cerebral oxygen saturation is stable because of constant CO and MAP, while the influence of CO on cerebral oxygen saturation seems to be more relevant. NCT01275898. © The Author 2016. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Serum cortisol concentration with exploratory cut-off values do not predict the effects of hydrocortisone administration in children with low cardiac output after cardiac surgery

    NARCIS (Netherlands)

    Verweij, E. J.; Hogenbirk, Karin; Roest, Arno A. W.; van Brempt, Ronald; Hazekamp, Mark G.; de Jonge, Evert

    2012-01-01

    Low cardiac output syndrome is common after paediatric cardiac surgery. Previous studies suggested that hydrocortisone administration may improve haemodynamic stability in case of resistant low cardiac output syndrome in critically ill children. This study was set up to test the hypothesis that the

  19. Evaluation of a new arterial pressure-based cardiac output device requiring no external calibration

    Directory of Open Access Journals (Sweden)

    Amann Matthias

    2007-11-01

    Full Text Available Abstract Background Several techniques have been discussed as alternatives to the intermittent bolus thermodilution cardiac output (COPAC measurement by the pulmonary artery catheter (PAC. However, these techniques usually require a central venous line, an additional catheter, or a special calibration procedure. A new arterial pressure-based cardiac output (COAP device (FloTrac™, Vigileo™; Edwards Lifesciences, Irvine, CA, USA only requires access to the radial or femoral artery using a standard arterial catheter and does not need an external calibration. We validated this technique in critically ill patients in the intensive care unit (ICU using COPAC as the method of reference. Methods We studied 20 critically ill patients, aged 16 to 74 years (mean, 55.5 ± 18.8 years, who required both arterial and pulmonary artery pressure monitoring. COPAC measurements were performed at least every 4 hours and calculated as the average of 3 measurements, while COAP values were taken immediately at the end of bolus determinations. Accuracy of measurements was assessed by calculating the bias and limits of agreement using the method described by Bland and Altman. Results A total of 164 coupled measurements were obtained. Absolute values of COPAC ranged from 2.80 to 10.80 l/min (mean 5.93 ± 1.55 l/min. The bias and limits of agreement between COPAC and COAP for unequal numbers of replicates was 0.02 ± 2.92 l/min. The percentage error between COPAC and COAP was 49.3%. The bias between percentage changes in COPAC (ΔCOPAC and percentage changes in COAP (ΔCOAP for consecutive measurements was -0.70% ± 32.28%. COPAC and COAP showed a Pearson correlation coefficient of 0.58 (p PAC and ΔCOAP was 0.46 (p Conclusion Although the COAP algorithm shows a minimal bias with COPAC over a wide range of values in an inhomogeneous group of critically ill patients, the scattering of the data remains relative wide. Therefore, the used algorithm (V 1.03 failed to

  20. Evaluation of a new arterial pressure-based cardiac output device requiring no external calibration

    Science.gov (United States)

    Prasser, Christopher; Bele, Sylvia; Keyl, Cornelius; Schweiger, Stefan; Trabold, Benedikt; Amann, Matthias; Welnhofer, Julia; Wiesenack, Christoph

    2007-01-01

    Background Several techniques have been discussed as alternatives to the intermittent bolus thermodilution cardiac output (COPAC) measurement by the pulmonary artery catheter (PAC). However, these techniques usually require a central venous line, an additional catheter, or a special calibration procedure. A new arterial pressure-based cardiac output (COAP) device (FloTrac™, Vigileo™; Edwards Lifesciences, Irvine, CA, USA) only requires access to the radial or femoral artery using a standard arterial catheter and does not need an external calibration. We validated this technique in critically ill patients in the intensive care unit (ICU) using COPAC as the method of reference. Methods We studied 20 critically ill patients, aged 16 to 74 years (mean, 55.5 ± 18.8 years), who required both arterial and pulmonary artery pressure monitoring. COPAC measurements were performed at least every 4 hours and calculated as the average of 3 measurements, while COAP values were taken immediately at the end of bolus determinations. Accuracy of measurements was assessed by calculating the bias and limits of agreement using the method described by Bland and Altman. Results A total of 164 coupled measurements were obtained. Absolute values of COPAC ranged from 2.80 to 10.80 l/min (mean 5.93 ± 1.55 l/min). The bias and limits of agreement between COPAC and COAP for unequal numbers of replicates was 0.02 ± 2.92 l/min. The percentage error between COPAC and COAP was 49.3%. The bias between percentage changes in COPAC (ΔCOPAC) and percentage changes in COAP (ΔCOAP) for consecutive measurements was -0.70% ± 32.28%. COPAC and COAP showed a Pearson correlation coefficient of 0.58 (p < 0.01), while the correlation coefficient between ΔCOPAC and ΔCOAP was 0.46 (p < 0.01). Conclusion Although the COAP algorithm shows a minimal bias with COPAC over a wide range of values in an inhomogeneous group of critically ill patients, the scattering of the data remains relative wide. Therefore

  1. Clinical skills: cardiac rhythm recognition and monitoring.

    Science.gov (United States)

    Sharman, Joanna

    With technological advances, changes in provision of healthcare services and increasing pressure on critical care services, ward patients' severity of illness is ever increasing. As such, nurses need to develop their skills and knowledge to care for their client group. Competency in cardiac rhythm monitoring is beneficial to identify changes in cardiac status, assess response to treatment, diagnosis and post-surgical monitoring. This paper describes the basic anatomy and physiology of the heart and its conduction system, and explains a simple and easy to remember process of analysing cardiac rhythms (Resuscitation Council UK, 2000) that can be used in first-line assessment to assist healthcare practitioners in providing care to their patients.

  2. The decrease of cardiac chamber volumes and output during positive-pressure ventilation

    DEFF Research Database (Denmark)

    Kristensen, Kasper Kyhl; Ahtarovski, Kiril Aleksov; Iversen, Kasper

    2013-01-01

    the effect of PPV on the central circulation by studying cardiac chamber volumes with cardiac magnetic resonance imaging (CMR). We hypothesized that PPV lowers cardiac output (CO) mainly via the Frank-Starling relationship. In 18 healthy volunteers, cardiac chamber volumes and flow in aorta and the pulmonary...... artery were measured by CMR during PPV levels of 0, 10, and 20 cmH2O applied via a respirator and a face mask. All cardiac chamber volumes decreased in proportion to the level of PPV. Following 20-cmH2O PPV, the total diastolic and systolic cardiac volumes (±SE) decreased from 605 (±29) ml to 446 (±29......) ml (P volume decreased by 27 (±4) ml/beat; heart rate increased by 7 (±2) beats/min; and CO decreased by 1.0 (±0.4) l/min (P

  3. Noninvasive pulse contour analysis for determination of cardiac output in patients with chronic heart failure.

    Science.gov (United States)

    Roth, Sebastian; Fox, Henrik; Fuchs, Uwe; Schulz, Uwe; Costard-Jäckle, Angelika; Gummert, Jan F; Horstkotte, Dieter; Oldenburg, Olaf; Bitter, Thomas

    2018-05-01

    Determination of cardiac output (CO) is essential in diagnosis and management of heart failure (HF). The gold standard to obtain CO is invasive assessment via thermodilution (TD). Noninvasive pulse contour analysis (NPCA) is supposed as a new method of CO determination. However, a validation of this method in HF is pending and performed in the present study. Patients with chronic-stable HF and reduced left ventricular ejection fraction (LVEF ≤ 45%; HF-REF) underwent right heart catheterization including TD. NPCA using the CNAP Monitor (V5.2.14, CNSystems Medizintechnik AG) was performed simultaneously. Three standardized TD measurements were compared with simultaneous auto-calibrated NPCA CO measurements. In total, 84 consecutive HF-REF patients were enrolled prospectively in this study. In 4 patients (5%), TD was not successful and for 22 patients (26%, 18 with left ventricular assist device), no NPCA signal could be obtained. For the remaining 58 patients, Bland-Altman analysis revealed a mean bias of + 1.92 L/min (limits of agreement ± 2.28 L/min, percentage error 47.4%) for CO. With decreasing cardiac index, as determined by the gold standard of TD, there was an increasing gap between CO values obtained by TD and NPCA (r = - 0.75, p TD-CI classified 52 (90%) patients to have a reduced CI (REF patients, auto-calibrated NPCA systematically overestimates CO with decrease in cardiac function. Therefore, to date, NPCA cannot be recommended in this cohort.

  4. Remote Monitoring of Cardiac Implantable Electronic Devices.

    Science.gov (United States)

    Cheung, Christopher C; Deyell, Marc W

    2018-01-08

    Over the past decade, technological advancements have transformed the delivery of care for arrhythmia patients. From early transtelephonic monitoring to new devices capable of wireless and cellular transmission, remote monitoring has revolutionized device care. In this article, we review the current evolution and evidence for remote monitoring in patients with cardiac implantable electronic devices. From passive transmission of device diagnostics, to active transmission of patient- and device-triggered alerts, remote monitoring can shorten the time to diagnosis and treatment. Studies have shown that remote monitoring can reduce hospitalization and emergency room visits, and improve survival. Remote monitoring can also reduce the health care costs, while providing increased access to patients living in rural or marginalized communities. Unfortunately, as many as two-thirds of patients with remote monitoring-capable devices do not use, or are not offered, this feature. Current guidelines recommend remote monitoring and interrogation, combined with annual in-person evaluation in all cardiac device patients. Remote monitoring should be considered in all eligible device patients and should be considered standard of care. Copyright © 2018 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  5. The relationship between cardiac output and dynamic cerebral autoregulation in humans.

    Science.gov (United States)

    Deegan, B M; Devine, E R; Geraghty, M C; Jones, E; Ólaighin, G; Serrador, J M

    2010-11-01

    Cerebral autoregulation adjusts cerebrovascular resistance in the face of changing perfusion pressures to maintain relatively constant flow. Results from several studies suggest that cardiac output may also play a role. We tested the hypothesis that cerebral blood flow would autoregulate independent of changes in cardiac output. Transient systemic hypotension was induced by thigh-cuff deflation in 19 healthy volunteers (7 women) in both supine and seated positions. Mean arterial pressure (Finapres), cerebral blood flow (transcranial Doppler) in the anterior (ACA) and middle cerebral artery (MCA), beat-by-beat cardiac output (echocardiography), and end-tidal Pco(2) were measured. Autoregulation was assessed using the autoregulatory index (ARI) defined by Tiecks et al. (Tiecks FP, Lam AM, Aaslid R, Newell DW. Stroke 26: 1014-1019, 1995). Cerebral autoregulation was better in the supine position in both the ACA [supine ARI: 5.0 ± 0.21 (mean ± SE), seated ARI: 3.9 ± 0.4, P = 0.01] and MCA (supine ARI: 5.0 ± 0.2, seated ARI: 3.8 ± 0.3, P = 0.004). In contrast, cardiac output responses were not different between positions and did not correlate with cerebral blood flow ARIs. In addition, women had better autoregulation in the ACA (P = 0.046), but not the MCA, despite having the same cardiac output response. These data demonstrate cardiac output does not appear to affect the dynamic cerebral autoregulatory response to sudden hypotension in healthy controls, regardless of posture. These results also highlight the importance of considering sex when studying cerebral autoregulation.

  6. Cardiac Output and Performance during a Marathon Race in Middle-Aged Recreational Runners

    OpenAIRE

    Billat, Véronique L.; Petot, Hélène; Landrain, Morgan; Meilland, Renaud; Koralsztein, Jean Pierre; Mille-Hamard, Laurence

    2012-01-01

    Purpose. Despite the increasing popularity of marathon running, there are no data on the responses of stroke volume (SV) and cardiac output (CO) to exercise in this context. We sought to establish whether marathon performance is associated with the ability to sustain high fractional use of maximal SV and CO (i.e, cardiac endurance) and/or CO, per meter (i.e., cardiac cost). Methods. We measured the SV, heart rate (HR), CO, and running speed of 14 recreational runners in an incremental, maxima...

  7. Rowing increases stroke volume and cardiac output to a greater extent than cycling

    Czech Academy of Sciences Publication Activity Database

    Horn, P.; Ošťádal, P.; Ošťádal, Bohuslav

    2015-01-01

    Roč. 64, č. 2 (2015), s. 203-207 ISSN 0862-8408 Institutional support: RVO:67985823 Keywords : cardiac output * cycling * heart rate * stroke volume Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery Impact factor: 1.643, year: 2015

  8. Relationship between stroke volume, cardiac output and filling of the heart during tilt

    DEFF Research Database (Denmark)

    Bundgaard-Nielsen, M.; Sorensen, H.; Dalsgaard, M.

    2009-01-01

    . With the supine resting position as a reference, we assessed stroke volume (SV), cardiac output (CO) and filling of the heart during graded tilt to evaluate whether SV and CO are maintained during an assumed maximal physiological filling of the heart elicited by 90 degrees HDT in healthy resting humans. METHODS...

  9. Middle cerebral artery blood velocity depends on cardiac output during exercise with a large muscle mass

    NARCIS (Netherlands)

    Ide, K.; Pott, F.; van Lieshout, J. J.; Secher, N. H.

    1998-01-01

    We tested the hypothesis that pharmacological reduction of the increase in cardiac output during dynamic exercise with a large muscle mass would influence the cerebral blood velocity/perfusion. We studied the relationship between changes in cerebral blood velocity (transcranial Doppler), rectus

  10. Non-invasive measurements of cardiac output in atrial fibrillation: Inert gas rebreathing and impedance cardiography

    DEFF Research Database (Denmark)

    Osbak, Philip S; Henriksen, Jens Henrik Sahl; Kofoed, Klaus F

    2011-01-01

    Abstract Background. Atrial fibrillation (AF) is associated with significant morbidity and mortality. To test the effect of interventions, knowledge of cardiac output (CO) is important. However, the irregular heart rate might cause some methods for determination of CO to have inherent weaknesses....

  11. Effect of Hemorrhage on Cardiac Output, PVP, Alodosterone and Diuresis during Immersion in Men

    Science.gov (United States)

    Simanonok, K.; Greenleaf, John E.; Bernauer, E. M.; Wade, C. E.; Keil, L. C.

    1990-01-01

    The purpose of this study was to test the hypothesis that a reduction in blood volume would attenuate or eliminate immersion-induced increases in cardiac output (Q (sup dot) sub co)) and urine excretion, and to investigate accompanying vasoactive and fluid-electrolyte hormonal responses.

  12. Cardiac output response to changes of the atrioventricular delay in different body positions and during exercise in patients receiving cardiac resynchronization therapy

    DEFF Research Database (Denmark)

    Ståhlberg, Marcus; Damgaard, Morten; Norsk, Peter

    2009-01-01

    AIMS: The aim of this study was to study the haemodynamic effect of atrioventricular delay (AVD) modifications within a narrow range in different body positions and during exercise in patients receiving cardiac resynchronization therapy (CRT). METHODS: The previously optimized AVD was shortened...... and prolonged by 40 ms in 27 CRT patients and 9 controls without heart failure. Cardiac output (CO) was measured by inert gas rebreathing (Innocor) as the average over different body positions (left-lateral, supine, sitting, standing, and exercise). In eight CRT patients with an implantable haemodynamic monitor......, the estimated pulmonary artery diastolic pressure (ePAD) was analysed. RESULTS: The magnitude of CO response to AVD changes was greater in CRT patients than in controls (0.25 vs. 0.20 L/min, Psize (r=0...

  13. Monitoring Linear Accelerator Output Constancy Using the PTW Linacheck

    International Nuclear Information System (INIS)

    McDermott, Garry M.; Buckle, Andrew H.

    2011-01-01

    The PTW-Linacheck was assessed for its ability to monitor linear accelerator radiation output constancy. The key issues that were considered were the setup for daily output measurements, e.g., requirements for build-up and backscatter material, and the reproducibility and linearity of the device with linear accelerator output. An appropriate measurement setup includes a 10 x 10 cm field at 100 cm FSD, 5 cm backscatter, and no added build-up for 4 MeV electron beams, 1 cm added build-up for 6-16 MeV electron beams and 5 cm added build-up for 6-15 MV photon beams. Using this measurement setup, the dose linearity and short-term reproducibility were acceptable; however, the Linacheck should be recalibrated on a monthly basis to ensure acceptable long-term reproducibility.

  14. The accuracy of PiCCO® in measuring cardiac output in patients under therapeutic hypothermia: Comparison with transthoracic echocardiography.

    Science.gov (United States)

    Souto Moura, T; Aguiar Rosa, S; Germano, N; Cavaco, R; Sequeira, T; Alves, M; Papoila, A L; Bento, L

    2018-03-01

    Invasive cardiac monitoring using thermodilution methods such as PiCCO® is widely used in critically ill patients and provides a wide range of hemodynamic variables, including cardiac output (CO). However, in post-cardiac arrest patients subjected to therapeutic hypothermia, the low body temperature possibly could interfere with the technique. Transthoracic Doppler echocardiography (ECHO) has long proved its accuracy in estimating CO, and is not influenced by temperature changes. To assess the accuracy of PiCCO® in measuring CO in patients under therapeutic hypothermia, compared with ECHO. Thirty paired COECHO/COPiCCO measurements were analyzed in 15 patients subjected to hypothermia after cardiac arrest. Eighteen paired measurements were obtained at under 36°C and 12 at ≥36°C. A value of 0.5l/min was considered the maximum accepted difference between the COECHO and COPiCCO values. Under conditions of normothermia (≥36°C), the mean difference between COECHO and COPiCCO was 0.030 l/min, with limits of agreement (-0.22, 0.28) - all of the measurements differing by less than 0.5 l/min. In situations of hypothermia (<36°C), the mean difference in CO measurements was -0.426 l/min, with limits of agreement (-1.60, 0.75), and only 44% (8/18) of the paired measurements fell within the interval (-0.5, 0.5). The calculated temperature cut-off point maximizing specificity was 35.95°C: above this temperature, specificity was 100%, with a false-positive rate of 0%. The results clearly show clinically relevant discordance between COECHO and COPiCCO at temperatures of <36°C, demonstrating the inaccuracy of PiCCO® for cardiac output measurements in hypothermic patients. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  15. Non-invasive cardiac output trending during exercise recovery on a bathroom-scale-based ballistocardiograph

    International Nuclear Information System (INIS)

    Inan, O T; Etemadi, M; Giovangrandi, L; Kovacs, G T A; Paloma, A

    2009-01-01

    Cardiac ejection of blood into the aorta generates a reaction force on the body that can be measured externally via the ballistocardiogram (BCG). In this study, a commercial bathroom scale was modified to measure the BCGs of nine healthy subjects recovering from treadmill exercise. During the recovery, Doppler echocardiogram signals were obtained simultaneously from the left ventricular outflow tract of the heart. The percentage changes in root-mean-square (RMS) power of the BCG were strongly correlated with the percentage changes in cardiac output measured by Doppler echocardiography (R 2 = 0.85, n = 275 data points). The correlation coefficients for individually analyzed data ranged from 0.79 to 0.96. Using Bland–Altman methods for assessing agreement, the mean bias was found to be −0.5% (±24%) in estimating the percentage changes in cardiac output. In contrast to other non-invasive methods for trending cardiac output, the unobtrusive procedure presented here uses inexpensive equipment and could be performed without the aid of a medical professional

  16. Non-invasive cardiac output trending during exercise recovery on a bathroom-scale-based ballistocardiograph.

    Science.gov (United States)

    Inan, O T; Etemadi, M; Paloma, A; Giovangrandi, L; Kovacs, G T A

    2009-03-01

    Cardiac ejection of blood into the aorta generates a reaction force on the body that can be measured externally via the ballistocardiogram (BCG). In this study, a commercial bathroom scale was modified to measure the BCGs of nine healthy subjects recovering from treadmill exercise. During the recovery, Doppler echocardiogram signals were obtained simultaneously from the left ventricular outflow tract of the heart. The percentage changes in root-mean-square (RMS) power of the BCG were strongly correlated with the percentage changes in cardiac output measured by Doppler echocardiography (R(2) = 0.85, n = 275 data points). The correlation coefficients for individually analyzed data ranged from 0.79 to 0.96. Using Bland-Altman methods for assessing agreement, the mean bias was found to be -0.5% (+/-24%) in estimating the percentage changes in cardiac output. In contrast to other non-invasive methods for trending cardiac output, the unobtrusive procedure presented here uses inexpensive equipment and could be performed without the aid of a medical professional.

  17. Is pulmonary gas exchange during exercise in hypoxia impaired with the increase of cardiac output?

    DEFF Research Database (Denmark)

    Calbet, J.A.; Robach, P.; Lundby, C.

    2008-01-01

    During exercise in humans, the alveolar-arterial O(2) tension difference ((A-a)DO(2)) increases with exercise intensity and is an important factor determining the absolute level of oxygen binding to hemoglobin and therefore the level of systemic oxygen transport. During exercise in hypoxia, the (A......-a)DO(2) is accentuated. Using the multiple inert gas elimination technique it has been shown that during exercise in acute hypoxia the contribution of ventilation-perfusion inequality to (A-a)DO(2) is rather small and in the absence of pulmonary edema intrapulmonary shunts can be ruled out. This implies...... that the main mechanism limiting pulmonary gas exchange is diffusion limitation. It is presumed that an elevation of cardiac output during exercise in acute hypoxia should increase the (A-a)DO(2). However, no studies have examined how variations in cardiac output independently affect pulmonary diffusion...

  18. Cardiac output and performance during a marathon race in middle-aged recreational runners.

    Science.gov (United States)

    Billat, Véronique L; Petot, Hélène; Landrain, Morgan; Meilland, Renaud; Koralsztein, Jean Pierre; Mille-Hamard, Laurence

    2012-01-01

    Despite the increasing popularity of marathon running, there are no data on the responses of stroke volume (SV) and cardiac output (CO) to exercise in this context. We sought to establish whether marathon performance is associated with the ability to sustain high fractional use of maximal SV and CO (i.e, cardiac endurance) and/or CO, per meter (i.e., cardiac cost). We measured the SV, heart rate (HR), CO, and running speed of 14 recreational runners in an incremental, maximal laboratory test and then during a real marathon race (mean performance: 3 hr 30 min ± 45 min). Our data revealed that HR, SV and CO were all in a high but submaximal steady state during the marathon (87.0 ± 1.6%, 77.2 ± 2.6%, and 68.7 ± 2.8% of maximal values, respectively). Marathon performance was inversely correlated with an upward drift in the CO/speed ratio (mL of CO × m(-1)) (r = -0.65, P marathon performance is inversely correlated with cardiac cost and positively correlated with cardiac endurance. The CO response could be a benchmark for race performance in recreational marathon runners.

  19. Pulmonary Artery Catheter (PAC Accuracy and Efficacy Compared with Flow Probe and Transcutaneous Doppler (USCOM: An Ovine Cardiac Output Validation

    Directory of Open Access Journals (Sweden)

    Robert A. Phillips

    2012-01-01

    Full Text Available Background. The pulmonary artery catheter (PAC is an accepted clinical method of measuring cardiac output (CO despite no prior validation. The ultrasonic cardiac output monitor (USCOM is a noninvasive alternative to PAC using Doppler ultrasound (CW. We compared PAC and USCOM CO measurements against a gold standard, the aortic flow probe (FP, in sheep at varying outputs. Methods. Ten conscious sheep, with implanted FPs, had measurements of CO by FP, USCOM, and PAC, at rest and during intervention with inotropes and vasopressors. Results. CO measurements by FP, PAC, and USCOM were 4.0±1.2 L/min, 4.8±1.5 L/min, and 4.0±1.4 L/min, respectively, (=280, range 1.9 L/min to 11.7 L/min. Percentage bias and precision between FP and PAC, and FP and USCOM was −17 and 47%, and 1 and 36%, respectively. PAC under-measured Dobutamine-induced CO changes by 20% (relative 66% compared with FP, while USCOM measures varied from FP by 3% (relative 10%. PAC reliably detected −30% but not +40% CO changes, as measured by receiver operating characteristic area under the curve (AUC, while USCOM reliably detected ±5% changes in CO (AUC>0.70. Conclusions. PAC demonstrated poor accuracy and sensitivity as a measure of CO. USCOM provided equivalent measurements to FP across a sixfold range of outputs, reliably detecting ±5% changes.

  20. Validation of an ultrasound dilution technology for cardiac output measurement and shunt detection in infants and children.

    Science.gov (United States)

    Lindberg, Lars; Johansson, Sune; Perez-de-Sa, Valeria

    2014-02-01

    To validate cardiac output measurements by ultrasound dilution technology (COstatus monitor) against those obtained by a transit-time ultrasound technology with a perivascular flow probe and to investigate ultrasound dilution ability to estimate pulmonary to systemic blood flow ratio in children. Prospective observational clinical trial. Pediatric cardiac operating theater in a university hospital. In 21 children (6.1 ± 2.6 kg, mean ± SD) undergoing heart surgery, cardiac output was simultaneously recorded by ultrasound dilution (extracorporeal arteriovenous loop connected to existing arterial and central venous catheters) and a transit-time ultrasound probe applied to the ascending aorta, and when possible, the main pulmonary artery. The pulmonary to systemic blood flow ratio estimated from ultrasound dilution curve analysis was compared with that estimated from transit-time ultrasound technology. Bland-Altman analysis of the whole cohort (90 pairs, before and after surgery) showed a bias between transit-time ultrasound (1.01 ± 0.47 L/min) and ultrasound dilution technology (1.03 ± 0.51 L/min) of -0.02 L/min, limits of agreement -0.3 to 0.3 L/min, and percentage error of 31%. In children with no residual shunts, the bias was -0.04 L/min, limits of agreement -0.28 to 0.2 L/min, and percentage error 19%. The pooled co efficient of variation was for the whole cohort 3.5% (transit-time ultrasound) and 6.3% (ultrasound dilution), and in children without shunt, it was 2.9% (transit-time ultrasound) and 4% (ultrasound dilution), respectively. Ultrasound dilution identified the presence of shunts (pulmonary to systemic blood flow ≠ 1) with a sensitivity of 100% and a specificity of 92%. Mean pulmonary to systemic blood flow ratio by transit-time ultrasound was 2.6 ± 1.0 and by ultrasound dilution 2.2 ± 0.7 (not significant). The COstatus monitor is a reliable technique to measure cardiac output in children with high sensitivity and specificity for detecting the

  1. The correlation between the first heart sound and cardiac output as measured by using digital esophageal stethoscope under anaesthesia.

    Science.gov (United States)

    Duck Shin, Young; Hoon Yim, Kyoung; Hi Park, Sang; Wook Jeon, Yong; Ho Bae, Jin; Soo Lee, Tae; Hwan Kim, Myoung; Jin Choi, Young

    2014-03-01

    The use of an esophageal stethoscope is a basic heart sounds monitoring procedure performed in patients under general anesthesia. As the size of the first heart sound can express the left ventricle function, its correlation with cardiac output should be investigated. The aim of this study was to investigate the effects of cardiac output (CO) on the first heart sound (S1) amplitude. Methods : Six male beagles were chosen. The S1 was obtained with the newly developed esophageal stethoscope system. CO was measured using NICOM, a non-invasive CO measuring device. Ephedrine and beta blockers were administered to the subjects to compare changes in figures, and the change from using an inhalation anesthetic was also compared. The S1 amplitude displayed positive correlation with the change rate of CO (r = 0.935, p < 0.001). The heart rate measured using the esophageal stethoscope and ECG showed considerably close figures through the Bland-Altman plot and showed a high positive correlation (r = 0.988, p < 0,001). In beagles, the amplitude of S1 had a significant correlation with changes in CO in a variety of situations.

  2. Monitoring radiation use in cardiac fluoroscopy imaging procedures

    Energy Technology Data Exchange (ETDEWEB)

    Stevens, Nathaniel T.; Steiner, Stefan H.; Smith, Ian R.; MacKay, R. Jock [Department of Statistics and Actuarial Sciences, Business and Industrial Statistics Research Group, University of Waterloo, Waterloo, Ontario N2L 3G1 (Canada); St. Andrew' s Medical Institute, St. Andrew' s War Memorial Hospital, Brisbane, Queensland 4000 (Australia); Department of Statistics and Actuarial Sciences, Business and Industrial Statistics Research Group, University of Waterloo, Waterloo, Ontario N2L 3G1 (Canada)

    2011-01-15

    Purpose: Timely identification of systematic changes in radiation delivery of an imaging system can lead to a reduction in risk for the patients involved. However, existing quality assurance programs involving the routine testing of equipment performance using phantoms are limited in their ability to effectively carry out this task. To address this issue, the authors propose the implementation of an ongoing monitoring process that utilizes procedural data to identify unexpected large or small radiation exposures for individual patients, as well as to detect persistent changes in the radiation output of imaging platforms. Methods: Data used in this study were obtained from records routinely collected during procedures performed in the cardiac catheterization imaging facility at St. Andrew's War Memorial Hospital, Brisbane, Australia, over the period January 2008-March 2010. A two stage monitoring process employing individual and exponentially weighted moving average (EWMA) control charts was developed and used to identify unexpectedly high or low radiation exposure levels for individual patients, as well as detect persistent changes in the radiation output delivered by the imaging systems. To increase sensitivity of the charts, we account for variation in dose area product (DAP) values due to other measured factors (patient weight, fluoroscopy time, and digital acquisition frame count) using multiple linear regression. Control charts are then constructed using the residual values from this linear regression. The proposed monitoring process was evaluated using simulation to model the performance of the process under known conditions. Results: Retrospective application of this technique to actual clinical data identified a number of cases in which the DAP result could be considered unexpected. Most of these, upon review, were attributed to data entry errors. The charts monitoring the overall system radiation output trends demonstrated changes in equipment

  3. Monitoring radiation use in cardiac fluoroscopy imaging procedures

    International Nuclear Information System (INIS)

    Stevens, Nathaniel T.; Steiner, Stefan H.; Smith, Ian R.; MacKay, R. Jock

    2011-01-01

    Purpose: Timely identification of systematic changes in radiation delivery of an imaging system can lead to a reduction in risk for the patients involved. However, existing quality assurance programs involving the routine testing of equipment performance using phantoms are limited in their ability to effectively carry out this task. To address this issue, the authors propose the implementation of an ongoing monitoring process that utilizes procedural data to identify unexpected large or small radiation exposures for individual patients, as well as to detect persistent changes in the radiation output of imaging platforms. Methods: Data used in this study were obtained from records routinely collected during procedures performed in the cardiac catheterization imaging facility at St. Andrew's War Memorial Hospital, Brisbane, Australia, over the period January 2008-March 2010. A two stage monitoring process employing individual and exponentially weighted moving average (EWMA) control charts was developed and used to identify unexpectedly high or low radiation exposure levels for individual patients, as well as detect persistent changes in the radiation output delivered by the imaging systems. To increase sensitivity of the charts, we account for variation in dose area product (DAP) values due to other measured factors (patient weight, fluoroscopy time, and digital acquisition frame count) using multiple linear regression. Control charts are then constructed using the residual values from this linear regression. The proposed monitoring process was evaluated using simulation to model the performance of the process under known conditions. Results: Retrospective application of this technique to actual clinical data identified a number of cases in which the DAP result could be considered unexpected. Most of these, upon review, were attributed to data entry errors. The charts monitoring the overall system radiation output trends demonstrated changes in equipment performance

  4. Serum cortisol concentration with exploratory cut-off values do not predict the effects of hydrocortisone administration in children with low cardiac output after cardiac surgery.

    Science.gov (United States)

    Verweij, E J; Hogenbirk, Karin; Roest, Arno A W; van Brempt, Ronald; Hazekamp, Mark G; de Jonge, Evert

    2012-10-01

    Low cardiac output syndrome is common after paediatric cardiac surgery. Previous studies suggested that hydrocortisone administration may improve haemodynamic stability in case of resistant low cardiac output syndrome in critically ill children. This study was set up to test the hypothesis that the effects of hydrocortisone on haemodynamics in children with low cardiac output syndrome depend on the presence of (relative) adrenal insufficiency. A retrospective study was done on paediatric patients who received hydrocortisone when diagnosed with resistant low cardiac output syndrome after paediatric cardiac surgery in the period from 1 November 2005 to 31 December 2008. We studied the difference in effects of treatment with hydrocortisone administration between patients with adrenal insufficiency defined as an exploratory cut-off value of total cortisol of cortisol of ≥ 100 nmol/l. A total of 62 of patients were enrolled, meeting the inclusion criteria for low cardiac output syndrome. Thirty-two patients were assigned to Group 1 (cortisol concentration and those with normal baseline cortisol levels. A cortisol value using an exploratory cut-off value of 100 nmol/l for adrenal insufficiency should not be used as a criterion to treat these patients with hydrocortisone.

  5. Mathematical basis for the measurement of absolute and fractional cardiac output with diffusible tracers by compartmental analysis methods

    International Nuclear Information System (INIS)

    Charkes, N.D.

    1984-01-01

    Using compartmental analysis methods, a mathematical basis is given for the measurement of absolute and fractional cardiac output with diffusible tracers. Cardiac output is shown to be the product of the blood volume and the sum of the rate constants of tracer egress from blood, modified by a factor reflecting transcapillary diffusibility, the transfer fraction. The return of tracer to the blood and distant (intracellular) events are shown to play no role in the solution. Fractional cardiac output is the ratio of the rate constant of tracer egress from blood to an organ, divided by the sum of the egress constants from blood. Predominantly extracellular ions such as sodium or bromide are best suited for this technique, although theoretically any diffusible tracer whose compartmental model can be solved may be used. It is shown that fractional cardiac output is independent of the transfer fraction, and therefore can be measured accurately by tracers which are not freely diffusible

  6. Optimizing Cardiac Out-Put to Increase Cerebral Penumbral Perfusion in Large Middle Cerebral Artery Ischemic Lesion—OPTIMAL Study

    Directory of Open Access Journals (Sweden)

    Hannah Fuhrer

    2017-08-01

    Full Text Available IntroductionIn unsuccessful vessel recanalization, clinical outcome of acute stroke patients depends on early improvement of penumbral perfusion. So far, mean arterial blood pressure (MAP is the target hemodynamic parameter. However, the correlations of MAP to cardiac output (CO and cerebral perfusion are volume state dependent. In severe subarachnoid hemorrhage, optimizing CO leads to a reduction of delayed ischemic neurological deficits and improvement of clinical outcome. This study aims to investigate the effect of standard versus advanced cardiac monitoring with optimization of CO on the clinical outcome in patients with large ischemic stroke.Methods and analysisThe OPTIMAL study is a prospective, multicenter, open, into two arms (1:1 randomized, controlled trial. Sample size estimate: sample sizes of 150 for each treatment group (300 in total ensure an 80% power to detect a difference of 16% of a dichotomized level of functional clinical outcome at 3 months at a significance level of 0.05. Study outcomes: the primary endpoint is the functional outcome at 3 months. The secondary endpoints include functional outcome at 6 months follow-up, and complications related to hemodynamic monitoring and therapies.DiscussionThe results of this trial will provide data on the safety and efficacy of advanced hemodynamic monitoring on clinical outcome.Ethics and disseminationThe trial was approved by the leading ethics committee of Freiburg University, Germany (438/14, 2015 and the local ethics committees of the participating centers. The study is performed in accordance with the Declaration of Helsinki and the guidelines of Good Clinical Practice. It is registered in the German Clinical Trial register (DRKS; DRKS00007805. Dissemination will include submission to peer-reviewed professional journals and presentation at congresses. Hemodynamic monitoring may be altered in a specific stroke patient cohort if the study shows that advanced monitoring is

  7. Chronic resuscitation after trauma-hemorrhage and acute fluid replacement improves hepatocellular function and cardiac output.

    Science.gov (United States)

    Remmers, D E; Wang, P; Cioffi, W G; Bland, K I; Chaudry, I H

    1998-01-01

    To determine whether prolonged (chronic) resuscitation has any beneficial effects on cardiac output and hepatocellular function after trauma-hemorrhage and acute fluid replacement. Acute fluid resuscitation after trauma-hemorrhage restores but does not maintain the depressed hepatocellular function and cardiac output. Male Sprague-Dawley rats underwent a 5-cm laparotomy (i.e., trauma was induced) and were bled to and maintained at a mean arterial pressure of 40 mmHg until 40% of maximal bleed-out volume was returned in the form of Ringer's lactate (RL). The animals were acutely resuscitated with RL using 4 times the volume of maximum bleed-out over 60 minutes, followed by chronic resuscitation of 0, 5, or 10 mL/kg/hr RL for 20 hours. Hepatocellular function was determined by an in vivo indocyanine green clearance technique. Hepatic microvascular blood flow was assessed by laser Doppler flowmetry. Plasma levels of interleukin-6 (IL-6) were determined by bioassay. Chronic resuscitation with 5 mL/kg/hr RL, but not with 0 or 10 mL/kg/hr RL, restored cardiac output, hepatocellular function, and hepatic microvascular blood flow at 20 hours after hemorrhage. The regimen above also reduced plasma IL-6 levels. Because chronic resuscitation with 5 mL/kg/hr RL after trauma-hemorrhage and acute fluid replacement restored hepatocellular function and hepatic microvascular blood flow and decreased plasma levels of IL-6, we propose that chronic fluid resuscitation in addition to acute fluid replacement should be routinely used in experimental studies of trauma-hemorrhage.

  8. Hereditary Hemorrhagic Telangiectasia Presenting as High Output Cardiac Failure during Pregnancy

    Directory of Open Access Journals (Sweden)

    Tareq Goussous

    2009-01-01

    Full Text Available High-output cardiac failure secondary to hepatic involvement is a rare complication of hereditary hemorrhagic telangiectasia (HHT. Here we report a 43-year-old woman who presented at 29 weeks gestation of her second pregnancy with complications of right-sided heart failure and preterm labor. After delivery via cesarean section, the patient was found to have intrahepatic arteriovenous malformations through non-invasive imaging. Subsequently, a family history of vascular malformations and epistaxis was elucidated and a diagnosis of HHT was made. This case is presented, along with a review of the literature and discussion of hepatic involvement in HHT with particular focus on the pregnant patient.

  9. Effects of levosimendan for low cardiac output syndrome in critically ill patients

    DEFF Research Database (Denmark)

    Koster, Geert; Wetterslev, Jørn; Gluud, Christian

    2015-01-01

    PURPOSE: To assess the benefits and harms of levosimendan for low cardiac output syndrome in critically ill patients. METHODS: We conducted a systematic review with meta-analyses and trial sequential analyses (TSA) of randomised clinical trials comparing levosimendan with any type of control. Two...... in the systematic review and 49 trials (6,688 patients) in the meta-analysis. One trial had low risk of bias and nine trials (2,490 patients) were considered lower risk of bias. Trials compared levosimendan with placebo, control interventions, and other inotropes. Pooling all trials including heterogenous...

  10. Cardiac output by pulse contour analysis does not match the increase measured by rebreathing during human spaceflight.

    Science.gov (United States)

    Hughson, Richard L; Peterson, Sean D; Yee, Nicholas J; Greaves, Danielle K

    2017-11-01

    Pulse contour analysis of the noninvasive finger arterial pressure waveform provides a convenient means to estimate cardiac output (Q̇). The method has been compared with standard methods under a range of conditions but never before during spaceflight. We compared pulse contour analysis with the Modelflow algorithm to estimates of Q̇ obtained by rebreathing during preflight baseline testing and during the final month of long-duration spaceflight in nine healthy male astronauts. By Modelflow analysis, stroke volume was greater in supine baseline than seated baseline or inflight. Heart rate was reduced in supine baseline so that there were no differences in Q̇ by Modelflow estimate between the supine (7.02 ± 1.31 l/min, means ± SD), seated (6.60 ± 1.95 l/min), or inflight (5.91 ± 1.15 l/min) conditions. In contrast, rebreathing estimates of Q̇ increased from seated baseline (4.76 ± 0.67 l/min) to inflight (7.00 ± 1.39 l/min, significant interaction effect of method and spaceflight, P < 0.001). Pulse contour analysis utilizes a three-element Windkessel model that incorporates parameters dependent on aortic pressure-area relationships that are assumed to represent the entire circulation. We propose that a large increase in vascular compliance in the splanchnic circulation invalidates the model under conditions of spaceflight. Future spaceflight research measuring cardiac function needs to consider this important limitation for assessing absolute values of Q̇ and stroke volume. NEW & NOTEWORTHY Noninvasive assessment of cardiac function during human spaceflight is an important tool to monitor astronaut health. This study demonstrated that pulse contour analysis of finger arterial blood pressure to estimate cardiac output failed to track the 46% increase measured by a rebreathing method. These results strongly suggest that alternative methods not dependent on pulse contour analysis are required to track cardiac function in spaceflight

  11. Cardiac Output and Performance during a Marathon Race in Middle-Aged Recreational Runners

    Directory of Open Access Journals (Sweden)

    Véronique L. Billat

    2012-01-01

    Full Text Available Purpose. Despite the increasing popularity of marathon running, there are no data on the responses of stroke volume (SV and cardiac output (CO to exercise in this context. We sought to establish whether marathon performance is associated with the ability to sustain high fractional use of maximal SV and CO (i.e, cardiac endurance and/or CO, per meter (i.e., cardiac cost. Methods. We measured the SV, heart rate (HR, CO, and running speed of 14 recreational runners in an incremental, maximal laboratory test and then during a real marathon race (mean performance: 3 hr 30 min ± 45 min. Results. Our data revealed that HR, SV and CO were all in a high but submaximal steady state during the marathon (87.0 ± 1.6%, 77.2 ± 2.6%, and 68.7 ± 2.8% of maximal values, respectively. Marathon performance was inversely correlated with an upward drift in the CO/speed ratio (mL of CO×m−1 (r=−0.65, P<0.01 and positively correlated with the runner’s ability to complete the race at a high percentage of the speed at maximal SV (r=0.83, P<0.0002. Conclusion. Our results showed that marathon performance is inversely correlated with cardiac cost and positively correlated with cardiac endurance. The CO response could be a benchmark for race performance in recreational marathon runners.

  12. The Unpredictable Effect of Changing Cardiac Output on Hypoxemia after Acute Pulmonary Thromboembolism

    Directory of Open Access Journals (Sweden)

    John Y. C. Tsang

    2008-01-01

    Full Text Available Previous studies reported that the degree of hypoxemia following acute pulmonary thromboembolism (APTE was highly variable and that its mechanism was mainly due to the creation of many high and low ventilation/perfusion (V/Q units, as a result of the heterogeneous regional blood flow (Q caused by embolic obstruction. We studied the effect of changing cardiac output (Q t on gas exchange after APTE in 5 embolized piglets (23 ± 3 Kg, using Dobutamine intermittently at approximately 20 μg/kg/min for 120 minutes. The distribution of ventilation (V and perfusion (Q at various times was mapped using fluorescent microspheres in 941 ± 60 lung regions. After APTE, increase in Q t by Dobutamine improved venous oxygen tension (PvO 2 but arterial PaO 2 did not change consistently. On the other hand, cluster analysis showed that the V/Q ratio of most lung regions was lowered due to increases in Q at the same time. We concluded that the effect of changing cardiac output on gas exchange following APTE was affected by the simultaneous and varying balance between the changing V/Q mismatch and the concomitantly changing PvO 2 , which might explain the unpredictability of PaO 2 in the clinical setting.

  13. The non-invasive and continuous estimation of cardiac output using a photoplethysmogram and electrocardiogram during incremental exercise

    International Nuclear Information System (INIS)

    Wang, L; Poon, C C Y; Zhang, Y T

    2010-01-01

    Cardiac output (CO) monitoring is not only essential for critically ill patients in the hospital, but also for patients at home and those undergoing cardiopulmonary exercise testing. However, CO is difficult to monitor during daily activities and exercise. In this paper, we aim at developing a novel CO estimation method that can be used under these challenging conditions. The tube model was utilized to derive a CO index, namely the pulse time reflection ratio (PTRR) from an electrocardiogram and photoplethysmogram. After calibration, the PTRR can be used to estimate beat-to-beat CO. The proposed method was verified against CO measured by impedance cardiography on 19 healthy subjects in an incremental intensity exercise test. Results showed that there were strong correlations (r) between the PTRR and reference CO in 18 subjects (mean r: 0.88, n = 245 trials). Two calibration approaches reported in the literature were applied to the proposed method and the corresponding bias ± precisions of estimation errors were 0 ± 1.89 L min −1 and −0.22 ± 2.12 L min −1 , respectively. The percent errors were 21.94% and 24.90%, smaller than the clinical acceptance limit (30%). To conclude, after calibration, this method can be used to monitor CO on healthy subjects during incremental intensity exercise

  14. Phlebotomy eliminates the maximal cardiac output response to six weeks of exercise training

    DEFF Research Database (Denmark)

    Bonne, Thomas Christian; Doucende, Gregory; Flück, Daniela

    2014-01-01

    With this study we tested the hypothesis that six weeks of endurance training increases maximal cardiac output (Qmax) relatively more by elevating blood volume (BV) than by inducing structural and functional changes within the heart. Nine healthy but untrained volunteers (VO2max 47 ± 5 ml.min(-1......).kg(-1)) underwent supervised training (60 min; 4 times weekly at 65% VO2max for six weeks) and Qmax was determined by inert gas re-breathing during cycle ergometer exercise before and after the training period. After the training period, blood volume (determined in duplicates by CO re......-breathing) was re-established to pre-training values by phlebotomy and Qmax was quantified again. Resting echography revealed no structural heart adaptations as a consequence of the training intervention. Following the training period, plasma volume (PV), red blood cell volume (RBCV) and BV increased (p...

  15. Reference values for total blood volume and cardiac output in humans

    Energy Technology Data Exchange (ETDEWEB)

    Williams, L.R. [Indiana Univ., South Bend, IN (United States). Division of Liberal Arts and Sciences

    1994-09-01

    Much research has been devoted to measurement of total blood volume (TBV) and cardiac output (CO) in humans but not enough effort has been devoted to collection and reduction of results for the purpose of deriving typical or {open_quotes}reference{close_quotes} values. Identification of normal values for TBV and CO is needed not only for clinical evaluations but also for the development of biokinetic models for ultra-short-lived radionuclides used in nuclear medicine (Leggett and Williams 1989). The purpose of this report is to offer reference values for TBV and CO, along with estimates of the associated uncertainties that arise from intra- and inter-subject variation, errors in measurement techniques, and other sources. Reference values are derived for basal supine CO and TBV in reference adult humans, and differences associated with age, sex, body size, body position, exercise, and other circumstances are discussed.

  16. Left ventricular atrioventricular plane displacement is preserved with lifelong endurance training and is the main determinant of maximal cardiac output

    DEFF Research Database (Denmark)

    Steding-Ehrenborg, Katarina; Boushel, Robert C; Calbet, José A

    2015-01-01

    subjects (29 ± 4 years) underwent cardiac MR. All subjects underwent maximal exercise testing and for elderly subjects maximal cardiac output during cycling was determined using dye dilution technique. RESULTS: Longitudinal and radial contribution to stroke volume did not differ between groups......BACKGROUND: Age-related decline in cardiac function can be prevented or postponed by lifelong endurance training. However, effects of normal ageing as well as of lifelong endurance exercise on longitudinal and radial contribution to stroke volume are unknown. The aim of this study was to determine...... groups for RVAVPD (P = 0.2). LVAVPD was an independent predictor of maximal cardiac output (R(2 = ) 0.61, P groups. However, how longitudinal pumping...

  17. Immediate changes in estimated cardiac output and vascular resistance after 60Co exposure in monkeys: implication for performance decrement

    International Nuclear Information System (INIS)

    Bruner, A.

    1977-01-01

    Aortic blood flow velocity, blood pressure, and heart rate were recorded in 12 unanesthetized, nonperforming monkeys during exposure to 1000 rad 60 Co at 129--164 rad/min. The first postradiation changes were seen within 3--4 min of the exposure's start and included tachycardia, a transient hypotension secondary to a loss in peripheral resistance, and a brief increase followed by a decrease to subnormal levels in cardiac output. The lowest cardiac output occurred between 10 and 20 min postexposure while blood pressure and peripheral resistance were recovering. It was proposed that the concurrent combination of low cardiac output, low blood pressure, and supranormal peripheral resistance might sufficiently attenuate cerebral perfusion temporarily to account for the transient behavioral decrements often seen during this time. Histamine release was postulated as responsible for this vascular shock syndrome

  18. Non-invasive measurement of cardiac output during anaesthesia. An evaluation of the soluble gas uptake method

    Energy Technology Data Exchange (ETDEWEB)

    Heneghan, C.P.; Branthwaite, M.A.

    1981-04-01

    A technique for measuring cardiac output which depends on the uptake of an inert soluble gas from the lungs has been evaluated during anesthesia. A respiratory mass spectrometer has been used to follow the concentrations of argon and freon-22 during passive rebreathing in anaesthetized patients before cardiopulmonary bypass. Values for cardiac output obtained with this technique are reproducible, but lower than those recorded using the direct Fick technique before and after the rebreathing manoeuvre. A reduction in cardiac output caused by vigorous rebreathing is the most likely explanation for the discrepancy and, although serial measurements of oxygen consumption may permit application of a correction factor, a method of measurement which causes significant haemodynamic disturbance cannot be recommended for widespread use.

  19. Transit time dispersion in pulmonary and systemic circulation: effects of cardiac output and solute diffusivity.

    Science.gov (United States)

    Weiss, Michael; Krejcie, Tom C; Avram, Michael J

    2006-08-01

    We present an in vivo method for analyzing the distribution kinetics of physiological markers into their respective distribution volumes utilizing information provided by the relative dispersion of transit times. Arterial concentration-time curves of markers of the vascular space [indocyanine green (ICG)], extracellular fluid (inulin), and total body water (antipyrine) measured in awake dogs under control conditions and during phenylephrine or isoproterenol infusion were analyzed by a recirculatory model to estimate the relative dispersions of transit times across the systemic and pulmonary circulation. The transit time dispersion in the systemic circulation was used to calculate the whole body distribution clearance, and an interpretation is given in terms of a lumped organ model of blood-tissue exchange. As predicted by theory, this relative dispersion increased linearly with cardiac output, with a slope that was inversely related to solute diffusivity. The relative dispersion of the flow-limited indicator antipyrine exceeded that of ICG (as a measure of intravascular mixing) only slightly and was consistent with a diffusional equilibration time in the extravascular space of approximately 10 min, except during phenylephrine infusion, which led to an anomalously high relative dispersion. A change in cardiac output did not alter the heterogeneity of capillary transit times of ICG. The results support the view that the relative dispersions of transit times in the systemic and pulmonary circulation estimated from solute disposition data in vivo are useful measures of whole body distribution kinetics of indicators and endogenous substances. This is the first model that explains the effect of flow and capillary permeability on whole body distribution of solutes without assuming well-mixed compartments.

  20. Nasal continuous positive airway pressure (n-CPAP) does not change cardiac output in preterm infants.

    Science.gov (United States)

    Moritz, Barbara; Fritz, Michael; Mann, Christian; Simma, Burkhard

    2008-02-01

    Our objective was to study how invasive mechanical ventilation impairs cardiac output (CO) in children and adults. Although the application of continuous positive airway pressure (CPAP) is widely practiced in neonatal intensive care, its hemodynamic consequences have not yet been investigated. A prospective study to assess the hemodynamic effects was conducted in 21 preterm infants CPAP (n-CPAP). Gestational age was 28.0 +/- 1.9 weeks (mean +/- standard deviation); birthweight, 1000 +/- 238 g; age at study entry, 200 +/- 155 hours; total maintenance fluid, 154 +/- 42 mL/kg/day; and n-CPAP level, 4.4 +/- 0.9 cm H(2)O. None of the infants received inotropic support, and n-CPAP did not cause any significant difference in the parameters measured: stroke volume, 3.1 +/- 1.0 mL (with n-CPAP) versus 3.1 +/- 1.0 mL (without n-CPAP); cardiac output, 487 +/- 156 mL/minute versus 500 +/- 176 mL/minute; left ventricular diastolic diameter, 1.22 +/- 0.15 cm versus 1.24 +/- 0.14 cm; fractional shortening, 0.30 +/- 0.05% versus 0.29 +/- 0.04%; and aortic velocity-time integral, 8.64 +/- 1.80 cm versus 8.70 +/- 1.65 cm. The n-CPAP level did not influence CO; n-CPAP (up to 7 cm H (2)O) has no echocardiographically detectable hemodynamic effect in preterm infants. Our data imply there is no need to withhold n-CPAP support to prevent circulatory compromise in these infants.

  1. Accuracy of Cardiac Output by Nine Different Pulse Contour Algorithms in Cardiac Surgery Patients: A Comparison with Transpulmonary Thermodilution

    Directory of Open Access Journals (Sweden)

    Ole Broch

    2016-01-01

    Full Text Available Objective. Today, there exist several different pulse contour algorithms for calculation of cardiac output (CO. The aim of the present study was to compare the accuracy of nine different pulse contour algorithms with transpulmonary thermodilution before and after cardiopulmonary bypass (CPB. Methods. Thirty patients scheduled for elective coronary surgery were studied before and after CPB. A passive leg raising maneuver was also performed. Measurements included CO obtained by transpulmonary thermodilution (COTPTD and by nine pulse contour algorithms (COX1–9. Calibration of pulse contour algorithms was performed by esophageal Doppler ultrasound after induction of anesthesia and 15 min after CPB. Correlations, Bland-Altman analysis, four-quadrant, and polar analysis were also calculated. Results. There was only a poor correlation between COTPTD and COX1–9 during passive leg raising and in the period before and after CPB. Percentage error exceeded the required 30% limit. Four-quadrant and polar analysis revealed poor trending ability for most algorithms before and after CPB. The Liljestrand-Zander algorithm revealed the best reliability. Conclusions. Estimation of CO by nine different pulse contour algorithms revealed poor accuracy compared with transpulmonary thermodilution. Furthermore, the less-invasive algorithms showed an insufficient capability for trending hemodynamic changes before and after CPB. The Liljestrand-Zander algorithm demonstrated the highest reliability. This trial is registered with NCT02438228 (ClinicalTrials.gov.

  2. In vivo validation of cardiac output assessment in non-standard 3D echocardiographic images

    Energy Technology Data Exchange (ETDEWEB)

    Nillesen, M M; Lopata, R G P; Gerrits, I H; Thijssen, J M; De Korte, C L [Clinical Physics Laboratory-833, Department of Pediatrics, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); De Boode, W P [Neonatology, Department of Pediatrics, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); Huisman, H J [Department of Radiology, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); Kapusta, L [Pediatric Cardiology, Department of Pediatrics, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands)], E-mail: m.m.nillesen@cukz.umcn.nl

    2009-04-07

    Automatic segmentation of the endocardial surface in three-dimensional (3D) echocardiographic images is an important tool to assess left ventricular (LV) geometry and cardiac output (CO). The presence of speckle noise as well as the nonisotropic characteristics of the myocardium impose strong demands on the segmentation algorithm. In the analysis of normal heart geometries of standardized (apical) views, it is advantageous to incorporate a priori knowledge about the shape and appearance of the heart. In contrast, when analyzing abnormal heart geometries, for example in children with congenital malformations, this a priori knowledge about the shape and anatomy of the LV might induce erroneous segmentation results. This study describes a fully automated segmentation method for the analysis of non-standard echocardiographic images, without making strong assumptions on the shape and appearance of the heart. The method was validated in vivo in a piglet model. Real-time 3D echocardiographic image sequences of five piglets were acquired in radiofrequency (rf) format. These ECG-gated full volume images were acquired intra-operatively in a non-standard view. Cardiac blood flow was measured simultaneously by an ultrasound transit time flow probe positioned around the common pulmonary artery. Three-dimensional adaptive filtering using the characteristics of speckle was performed on the demodulated rf data to reduce the influence of speckle noise and to optimize the distinction between blood and myocardium. A gradient-based 3D deformable simplex mesh was then used to segment the endocardial surface. A gradient and a speed force were included as external forces of the model. To balance data fitting and mesh regularity, one fixed set of weighting parameters of internal, gradient and speed forces was used for all data sets. End-diastolic and end-systolic volumes were computed from the segmented endocardial surface. The cardiac output derived from this automatic segmentation was

  3. In vivo validation of cardiac output assessment in non-standard 3D echocardiographic images

    International Nuclear Information System (INIS)

    Nillesen, M M; Lopata, R G P; Gerrits, I H; Thijssen, J M; De Korte, C L; De Boode, W P; Huisman, H J; Kapusta, L

    2009-01-01

    Automatic segmentation of the endocardial surface in three-dimensional (3D) echocardiographic images is an important tool to assess left ventricular (LV) geometry and cardiac output (CO). The presence of speckle noise as well as the nonisotropic characteristics of the myocardium impose strong demands on the segmentation algorithm. In the analysis of normal heart geometries of standardized (apical) views, it is advantageous to incorporate a priori knowledge about the shape and appearance of the heart. In contrast, when analyzing abnormal heart geometries, for example in children with congenital malformations, this a priori knowledge about the shape and anatomy of the LV might induce erroneous segmentation results. This study describes a fully automated segmentation method for the analysis of non-standard echocardiographic images, without making strong assumptions on the shape and appearance of the heart. The method was validated in vivo in a piglet model. Real-time 3D echocardiographic image sequences of five piglets were acquired in radiofrequency (rf) format. These ECG-gated full volume images were acquired intra-operatively in a non-standard view. Cardiac blood flow was measured simultaneously by an ultrasound transit time flow probe positioned around the common pulmonary artery. Three-dimensional adaptive filtering using the characteristics of speckle was performed on the demodulated rf data to reduce the influence of speckle noise and to optimize the distinction between blood and myocardium. A gradient-based 3D deformable simplex mesh was then used to segment the endocardial surface. A gradient and a speed force were included as external forces of the model. To balance data fitting and mesh regularity, one fixed set of weighting parameters of internal, gradient and speed forces was used for all data sets. End-diastolic and end-systolic volumes were computed from the segmented endocardial surface. The cardiac output derived from this automatic segmentation was

  4. In vivo validation of cardiac output assessment in non-standard 3D echocardiographic images

    Science.gov (United States)

    Nillesen, M. M.; Lopata, R. G. P.; de Boode, W. P.; Gerrits, I. H.; Huisman, H. J.; Thijssen, J. M.; Kapusta, L.; de Korte, C. L.

    2009-04-01

    Automatic segmentation of the endocardial surface in three-dimensional (3D) echocardiographic images is an important tool to assess left ventricular (LV) geometry and cardiac output (CO). The presence of speckle noise as well as the nonisotropic characteristics of the myocardium impose strong demands on the segmentation algorithm. In the analysis of normal heart geometries of standardized (apical) views, it is advantageous to incorporate a priori knowledge about the shape and appearance of the heart. In contrast, when analyzing abnormal heart geometries, for example in children with congenital malformations, this a priori knowledge about the shape and anatomy of the LV might induce erroneous segmentation results. This study describes a fully automated segmentation method for the analysis of non-standard echocardiographic images, without making strong assumptions on the shape and appearance of the heart. The method was validated in vivo in a piglet model. Real-time 3D echocardiographic image sequences of five piglets were acquired in radiofrequency (rf) format. These ECG-gated full volume images were acquired intra-operatively in a non-standard view. Cardiac blood flow was measured simultaneously by an ultrasound transit time flow probe positioned around the common pulmonary artery. Three-dimensional adaptive filtering using the characteristics of speckle was performed on the demodulated rf data to reduce the influence of speckle noise and to optimize the distinction between blood and myocardium. A gradient-based 3D deformable simplex mesh was then used to segment the endocardial surface. A gradient and a speed force were included as external forces of the model. To balance data fitting and mesh regularity, one fixed set of weighting parameters of internal, gradient and speed forces was used for all data sets. End-diastolic and end-systolic volumes were computed from the segmented endocardial surface. The cardiac output derived from this automatic segmentation was

  5. Depressed left and right ventricular cardiac output in fetuses of diabetic mothers

    Directory of Open Access Journals (Sweden)

    Jennifer Winter MD

    2018-01-01

    Full Text Available Introduction: We compared right and left ventricular cardiac output (RVCO and LVCO in fetuses of diabetic mothers (FDM with a large normal cohort. Methods: We prospectively enrolled 264 normal fetuses and 30 FDM. Fetal CO parameters such as semilunar valve velocity time integrals (AVVTI, PVVTI, ventricular outflow diameters (LVOTD, RVOTD and stroke volumes (AVSV, PVSV were measured, and LVCO and RVCO were calculated. These were normalized using non-linear regression to estimated fetal weight (EFW to provide means and standard deviations. Among FDMs, mean Z scores and 95% confidence limits (CL were calculated and compared to zero. Results: LVCO, RVCO and parameters they were calculated from, increased predictably and non-linearly with increasing EFW. In FDM, LVCO was depressed (mean Z −1.679, 95% CL −2.404, −0.955, P < 0.001, and AVVTI, LVOTD and AVSV were significantly lower than normal. Similarly, RVCO (mean Z = −1.119, CL −1.839, −0.400, P = 0.003, RVOTD (mean −2.085, CL −3.077, −1.093, P < 0.001 and PVSV (mean −1.184, CL −1.921, −0.446, P = 0.003 were lower than normal, however, PVVTI was not different (mean Z 0.078, CL −0.552, +0.707, P = 0.803. Conclusion: Normal biventricular stroke volumes and outputs follow a non-linear regression with EFW. FDM have significantly lower right and left heart stroke volumes and outputs for weight than do normal fetuses.

  6. In Vivo Self-Powered Wireless Cardiac Monitoring via Implantable Triboelectric Nanogenerator.

    Science.gov (United States)

    Zheng, Qiang; Zhang, Hao; Shi, Bojing; Xue, Xiang; Liu, Zhuo; Jin, Yiming; Ma, Ye; Zou, Yang; Wang, Xinxin; An, Zhao; Tang, Wei; Zhang, Wei; Yang, Fan; Liu, Yang; Lang, Xilong; Xu, Zhiyun; Li, Zhou; Wang, Zhong Lin

    2016-07-26

    Harvesting biomechanical energy in vivo is an important route in obtaining sustainable electric energy for powering implantable medical devices. Here, we demonstrate an innovative implantable triboelectric nanogenerator (iTENG) for in vivo biomechanical energy harvesting. Driven by the heartbeat of adult swine, the output voltage and the corresponding current were improved by factors of 3.5 and 25, respectively, compared with the reported in vivo output performance of biomechanical energy conversion devices. In addition, the in vivo evaluation of the iTENG was demonstrated for over 72 h of implantation, during which the iTENG generated electricity continuously in the active animal. Due to its excellent in vivo performance, a self-powered wireless transmission system was fabricated for real-time wireless cardiac monitoring. Given its outstanding in vivo output and stability, iTENG can be applied not only to power implantable medical devices but also possibly to fabricate a self-powered, wireless healthcare monitoring system.

  7. Electro-resistive bands for non-invasive cardiac and respiration monitoring, a feasibility study

    International Nuclear Information System (INIS)

    Gargiulo, Gaetano D; Breen, Paul P; O’Loughlin, Aiden

    2015-01-01

    Continuous unobtrusive monitoring of tidal volume, particularly for critical care patients (i.e. neonates and patients in intensive care) during sleep studies and during daily activities, is still an unresolved monitoring need. Also a successful monitoring solution is yet to be proposed for continuous non-invasive cardiac stroke volume monitoring that is a novel clinical need. In this paper we present the feasibility study for a wearable, non-invasive, non-contact and unobtrusive sensor (embedded in a standard T-shirt) based on four electro-resistive bands that simultaneously monitors tidal volume and cardiac stroke volume changes. This low power sensor system (requires only 100 mW and accepts a wide power supply range up to ±18 V); thus the sensor can be easily embedded in existing wearable solutions (i.e. Holter monitors). Moreover, being contactless, it can be worn over bandages or electrodes, and as it does not rely over the integrity of the garment to work, it allows practitioners to perform procedures during monitoring. For this preliminary evaluation, one subject has worn the sensor over the period of 24 h (removing it only to shower); the accuracy of the tidal volume tested against a portable spirometer reported a precision of ±10% also during physical activity; accuracy tests for cardiac output (as it may require invasive procedure) have not been carried out in this preliminary trial. (note)

  8. Impact of pacing modality and biventricular pacing on cardiac output and coronary conduit flow in the post-cardiotomy patient.

    LENUS (Irish Health Repository)

    Healy, David G

    2012-02-03

    We have previously demonstrated the role of univentricular pacing modalities in influencing coronary conduit flow in the immediate post-operative period in the cardiac surgery patient. We wanted to determine the mechanism of this improved coronary conduit and, in addition, to explore the possible benefits with biventricular pacing. Sixteen patients undergoing first time elective coronary artery bypass grafting who required pacing following surgery were recruited. Comparison of cardiac output and coronary conduit flow was performed between VVI and DDD pacing with a single right ventricular lead and biventricular pacing lead placement. Cardiac output was measured using arterial pulse waveform analysis while conduit flow was measured using ultrasonic transit time methodology. Cardiac output was greatest with DDD pacing using right ventricular lead placement only [DDD-univentricular 5.42 l (0.7), DDD-biventricular 5.33 l (0.8), VVI-univentricular 4.71 l (0.8), VVI-biventricular 4.68 l (0.6)]. DDD-univentricular pacing was significantly better than VVI-univentricular (P=0.023) and VVI-biventricular pacing (P=0.001) but there was no significant advantage to DDD-biventricular pacing (P=0.45). In relation to coronary conduit flow, DDD pacing again had the highest flow [DDD-univentricular 55 ml\\/min (24), DDD-biventricular 52 ml\\/min (25), VVI-univentricular 47 ml\\/min (23), VVI-biventricular 50 ml\\/min (26)]. DDD-univentricular pacing was significantly better than VVI-univentricular (P=0.006) pacing but not significantly different to VVI-biventricular pacing (P=0.109) or DDD-biventricular pacing (P=0.171). Pacing with a DDD modality offers the optimal coronary conduit flow by maximising cardiac output. Biventricular lead placement offered no significant benefit to coronary conduit flow or cardiac output.

  9. Pulmonary diffusing capacity, capillary blood volume, and cardiac output during sustained microgravity

    Science.gov (United States)

    Prisk, G. K.; Guy, Harold J. B.; Elliott, Ann R.; Deutschman, Robert A., III; West, John B.

    1993-01-01

    We measured pulmonary diffusing capacity (DL), diffusing capacity per unit lung volume, pulmonary capillary blood volume (Vc), membrane diffusing capacity (Dm), pulmonary capillary blood flow or cardiac output (Qc), and cardiac stroke volume (SV) in four subjects exposed to nine days of microgravity. DL in microgravity was elevated compared with preflight standing values and was higher than preflight supine because of the elevation of both Vc and Dm. The elevation in Vc was comparable to that measured supine in 1 G, but the increase in Dm was in sharp contrast to the supine value. We postulate that, in 0 G, pulmonary capillary blood is evenly distributed throughout the lung, providing for uniform capillary filling, leading to an increase in the surface area available for diffusion. By contrast, in the supine 1-G state, the capillaries are less evenly filled, and although a similar increase in blood volume is observed, the corresponding increase in surface area does not occur. DL and its subdivisions showed no adaptive changes from the first measurement 24 h after the start of 0 G to eight days later. Similarly, there were no trends in the postflight data, suggesting that the principal mechanism of these changes was gravitational. The increase in Dm suggests that subclinical pulmonary edema did not result from exposure to 0 G. Qc was modestly increased inflight and decreased postflight compared with preflight standing. Compared with preflight standing, SV was increased 46 percent inflight and decreased 14 percent in the 1st week postflight. There were temporal changes in Qc and SV during 0 G, with the highest values recorded at the first measurement, 24 h into the flight. The lowest values of Qc and SV occurred on the day of return.

  10. Pilot Study: Estimation of Stroke Volume and Cardiac Output from Pulse Wave Velocity.

    Directory of Open Access Journals (Sweden)

    Yurie Obata

    Full Text Available Transesophageal echocardiography (TEE is increasingly replacing thermodilution pulmonary artery catheters to assess hemodynamics in patients at high risk for cardiovascular morbidity. However, one of the drawbacks of TEE compared to pulmonary artery catheters is the inability to measure real time stroke volume (SV and cardiac output (CO continuously. The aim of the present proof of concept study was to validate a novel method of SV estimation, based on pulse wave velocity (PWV in patients undergoing cardiac surgery.This is a retrospective observational study. We measured pulse transit time by superimposing the radial arterial waveform onto the continuous wave Doppler waveform of the left ventricular outflow tract, and calculated SV (SVPWV using the transformed Bramwell-Hill equation. The SV measured by TEE (SVTEE was used as a reference.A total of 190 paired SV were measured from 28 patients. A strong correlation was observed between SVPWV and SVTEE with the coefficient of determination (R2 of 0.71. A mean difference between the two (bias was 3.70 ml with the limits of agreement ranging from -20.33 to 27.73 ml and a percentage error of 27.4% based on a Bland-Altman analysis. The concordance rate of two methods was 85.0% based on a four-quadrant plot. The angular concordance rate was 85.9% with radial limits of agreement (the radial sector that contained 95% of the data points of ± 41.5 degrees based on a polar plot.PWV based SV estimation yields reasonable agreement with SV measured by TEE. Further studies are required to assess its utility in different clinical situations.

  11. Management of perioperative low cardiac output state without extracorporeal life support: What is feasible?

    International Nuclear Information System (INIS)

    Kumar, Girish; Iyer, Parvathi U

    2010-01-01

    A transient and reversible reduction in cardiac output–low cardiac output state (LCOS) often occurs following surgery for congenital heart disease. Inappropriately managed LCOS is a risk factor for increased morbidity and death. LCOS may occasionally be progressive and refractory needing a period of “myocardial rest” with extracorporeal life support (ECLS). ECLS is currently considered a routine tool available for rapid deployment in most industrialized countries. Accumulated experience and refinements in technology have led to improving survivals – discharge survivals of 35%–50%, with almost 100% survival in select groups on elective left ventricular assist device. Thus, there is an increasing trend to initiate ECLS “early or electively in the operating room” in high-risk patients. India has a huge potential need for ECLS given the large number of infants presenting late with preexisting ventricular dysfunction or in circulatory collapse. ECLS is an expensive and resource consuming treatment modality and is not a viable therapeutic option in our country. The purpose of this paper is to reiterate an anticipatory, proactive approach to LCOS: (1) methods for early detection of evolving LCOS and (2) timely initiation of individualized therapy. This paper also explores what is feasible with the refinement of “simple, conventional, inexpensive strategies” for the management of LCOS. Therapy for LCOS should be multimodal based on the type of circulation and physiology. Our approach to LCOS includes: (1) intraoperative strategies, (2) aggressive afterload reduction, (3) lusitropy, (4) exclusion of structural defects, (5) harnessing cardiopulmonary interactions, and (6) addressing metabolic and endocrine abnormalities. We have achieved a discharge survival rate of greater than 97% with these simple methods

  12. Individual differences in episodic memory abilities predict successful prospective memory output monitoring.

    Science.gov (United States)

    Hunter Ball, B; Pitães, Margarida; Brewer, Gene A

    2018-02-07

    Output monitoring refers to memory for one's previously completed actions. In the context of prospective memory (PM) (e.g., remembering to take medication), failures of output monitoring can result in repetitions and omissions of planned actions (e.g., over- or under-medication). To be successful in output monitoring paradigms, participants must flexibly control attention to detect PM cues as well as engage controlled retrieval of previous actions whenever a particular cue is encountered. The current study examined individual differences in output monitoring abilities in a group of younger adults differing in attention control (AC) and episodic memory (EM) abilities. The results showed that AC ability uniquely predicted successful cue detection on the first presentation, whereas EM ability uniquely predicted successful output monitoring on the second presentation. The current study highlights the importance of examining external correlates of PM abilities and contributes to the growing body of research on individual differences in PM.

  13. Evaluation of concordance among three cardiac output measurement techniques in adult patients during cardiovascular surgery postoperative care.

    Science.gov (United States)

    Muñoz, L; Velandia, A; Reyes, L E; Arevalo-Rodríguez, I; Mejía, C; Asprilla, D; Uribe, D V; Arevalo, J J

    2017-12-01

    The standard method for cardiac output measuring is thermodilution although it is an invasive technique. Transesophageal Echocardiography (TEE) offers a dynamic and functional alternative to thermodilution. Analyze concordance between two TEE methods and thermodilution for cardiac output assessment. Observational concordance study in cardiovascular surgery patients that required pulmonary artery catheter. TEE cardiac output measurement at both mitral annulus (MA) and left ventricle outflow tract (LVOT) were performed. Results were compared with thermodilution. Correlation was evaluated by Lin's concordance correlation coefficient and Bland-Altman analysis. Statistical analysis was undertaken in STATA 13.0. Twenty-five patients were enrolled. Fifty two percent of patients were male, median age and ejection fraction was 63 years and 35% respectively. Median thermodilution, LVOT and MA -measured cardiac output was 3.25 L/min, 3.46 L/min and 8.4 L/min respectively. Different values between thermodilution and MA measurements were found (Lin concordance=0.071; Confidence Interval 95%=-0.009 to 0.151; Spearman's correlation=0.22) as values between thermodilution and LVOT (Lin concordance=0.232; Confidence Interval 95%=-0.12 a 0.537; Spearman's correlation 0.28). Bland-Altman analysis showed greater difference between MA measurements and thermodilution (DM=-0.408; Bland-Altman Limits=-0.809 to -0.007), than the other echocardiographic findings (DM=0.007; Bland-Altman Limits=-0.441 to 0.428). Results from cardiac output measurement by doppler and 2D-TEE on both MA and LVOT do not correlate with those obtained by thermodilution. Copyright © 2017 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  14. A comparison of dobutamine and levosimendan on hepatic blood flow in patients with a low cardiac output state after cardiac surgery: a randomised controlled study.

    Science.gov (United States)

    Alvarez, J; Baluja, A; Selas, S; Otero, P; Rial, M; Veiras, S; Caruezo, V; Taboada, M; Rodriguez, I; Castroagudin, J; Tome, S; Rodriguez, A; Rodriguez, J

    2013-11-01

    Liver dysfunction due to a low cardiac output state after cardiac surgery is associated with a poor prognosis, but whether one inotrope is superior to another in improving hepatic perfusion remains uncertain. This study compared the systemic and hepatic haemodynamic effects of levosimendan to dobutamine in patients with a low cardiac output state (cardiac index flow (ml/min): 614.0±124.7, 585.9±144.8; pulsatility index: 2.02±0,28, 2.98±0.27 versus the levosimendan group: cardiac index: 3.02± 0.27, 2.98± 0.30; portal vein flow: 723.0± 143.5, 702.9±117.8; pulsatility index: 1.71±0.26, 1.73±0.27). The improvement in portal vein blood flow at 48 hours was significantly better after levosimendan than dobutamine (41% vs. 11% increment from baseline, Pflow through both the hepatic artery and portal venous system, whereas dobutamine can only improve the portal venous blood flow without vasodilating the hepatic artery.

  15. Effects of cardiac output on the onset of rocuronium-induced neuromuscular block in elderly patients.

    Science.gov (United States)

    Shiraishi, Naoki; Aono, Mayu; Kameyama, Yasuhito; Yamamoto, Mai; Kitajima, Osamu; Suzuki, Takahiro

    2018-05-21

    The aim of this study was to elucidate the relationship between the onset of rocuronium-induced neuromuscular block and arterial pressure-based cardiac output (CO) in elderly patients. Forty elderly patients aged 65-83 years were enrolled in this study. After induction of anesthesia, contractions of the adductor pollicis muscle to ulnar nerve train-of-four stimulation were acceleromyographically evaluated and 1 mg/kg rocuronium was administered following CO measurement. The correlation between onset of rocuronium action and CO was analyzed. The mean [SD] CO reduced after induction of anesthesia from 5.1 [1.8] L/min to 3.8 [1.1] L/min. The onset time of rocuronium-induced neuromuscular block was 110.3 [23.9] s (range 60-165). There was a statistically significant inverse correlation between the onset time of rocuronium and CO [onset time (s) = - 13.2·CO + 159.7, R 2  = 0.376]. In the elderly, CO influences the onset of action of rocuronium.

  16. Association of HeartMate II left ventricular assist device flow estimate with thermodilution cardiac output.

    Science.gov (United States)

    Hasin, Tal; Huebner, Marianne; Li, Zhuo; Brown, Daniel; Stulak, John M; Boilson, Barry A; Joyce, Lyle; Pereira, Naveen L; Kushwaha, Sudhir S; Park, Soon J

    2014-01-01

    Cardiac output (CO) assessment is important in treating patients with heart failure. Durable left ventricular assist devices (LVADs) provide essentially all CO. In currently used LVADs, estimated device flow is generated by a computerized algorithm. However, LVAD flow estimate may be inaccurate in tracking true CO. We correlated LVAD (HeartMate II) flow with thermodilution CO during postoperative care (day 2-10 after implant) in 81 patients (5,616 paired measurements). Left ventricular assist device flow and CO correlated with a low correlation coefficient (r = 0.42). Left ventricular assist device readings were lower than CO measurements by approximately 0.36 L/min, trending for larger difference with higher values. Left ventricular assist device flow measurements showed less temporal variability compared with CO. Grouping for simultaneous measured blood pressure (BP device flow generally trends with measured CO, but large variability exists, hence flow measures should not be assumed to equal with CO. Clinicians should take into account variables such as high CO, BP, and opening of the aortic valve when interpreting LVAD flow readout. Direct flow sensors incorporated in the LVAD system may allow for better estimation.

  17. Prevalence of nursing diagnosis of decreased cardiac output and the predictive value of defining characteristics in patients under evaluation for heart transplant

    OpenAIRE

    Matos, Lígia Neres; Guimarães, Tereza Cristina Felippe; Brandão, Marcos Antônio Gomes; Santoro, Deyse Conceição

    2012-01-01

    The purposes of the study were to identify the prevalence of defining characteristics (DC) of decreased cardiac output (DCO) in patients with cardiac insufficiency under evaluation for heart transplantation, and to ascertain the likelihood of defining characteristics being predictive factors for the existence of reduction in cardiac output. Data was obtained by retrospective documental analysis of the clinical records of right-sided heart catheterizations in 38 patients between 2004 and 2009....

  18. Children with Burn Injury Have Impaired Cardiac Output during Submaximal Exercise.

    Science.gov (United States)

    Rivas, Eric; Herndon, David N; Beck, Kenneth C; Suman, Oscar E

    2017-10-01

    Burn trauma damages resting cardiac function; however, it is currently unknown if the cardiovascular response to exercise is likewise impaired. We tested the hypothesis that, in children, burn injury lowers cardiac output (Q˙) and stroke volume (SV) during submaximal exercise. Five children with 49% ± 4% total body surface area (BSA) burned (two female, 11.7 ± 1 yr, 40.4 ± 18 kg, 141.1 ± 9 cm) and eight similar nonburned controls (five female, 12.5 ± 2 yr, 58.0 ± 17 kg, 147.3 ± 12 cm) with comparable exercise capacity (peak oxygen consumption [peak V˙O2]: 31.9 ± 11 vs 36.8 ± 8 mL O2·kg·min, P = 0.39) participated. The exercise protocol entailed a preexercise (pre-EX) rest period followed by 3-min exercise stages at 20 W and 50 W. V˙O2, HR, Q˙ (via nonrebreathing), SV (Q˙/HR), and arteriovenous O2 difference ([a-v]O2diff, Q˙/ V˙O2) were the primary outcome variables. Using a 2-way factorial ANOVA (group [G] × exercise [EX]), we found that Q˙ was approximately 27% lower in the burned than the nonburned group at 20 W of exercise (burned 5.7 ± 1.0 vs nonburned: 7.9 ± 1.8 L·min) and 50 W of exercise (burned 6.9 ± 1.6 vs nonburned 9.2 ± 3.2 L·min) (G-EX interaction, P = 0.012). SV did not change from rest to exercise in burned children but increased by approximately 24% in the nonburned group (main effect for EX, P = 0.046). Neither [a-v] O2diff nor V˙O2 differed between groups at rest or exercise, but HR response to exercise was reduced in the burn group (G-EX interaction, P = 0.004). When normalized to BSA, SV (index) was similar between groups; however, Q˙ (index) remained attenuated in the burned group (G-EX interaction, P exercise. Further investigation of hemodynamic function during exercise will provide insights important for cardiovascular rehabilitation in burned children.

  19. Assessment of interchangeability rate between 2 methods of measurements: An example with a cardiac output comparison study.

    Science.gov (United States)

    Lorne, Emmanuel; Diouf, Momar; de Wilde, Robert B P; Fischer, Marc-Olivier

    2018-02-01

    The Bland-Altman (BA) and percentage error (PE) methods have been previously described to assess the agreement between 2 methods of medical or laboratory measurements. This type of approach raises several problems: the BA methodology constitutes a subjective approach to interchangeability, whereas the PE approach does not take into account the distribution of values over a range. We describe a new methodology that defines an interchangeability rate between 2 methods of measurement and cutoff values that determine the range of interchangeable values. We used a simulated data and a previously published data set to demonstrate the concept of the method. The interchangeability rate of 5 different cardiac output (CO) pulse contour techniques (Wesseling method, LiDCO, PiCCO, Hemac method, and Modelflow) was calculated, in comparison with the reference pulmonary artery thermodilution CO using our new method. In our example, Modelflow with a good interchangeability rate of 93% and a cutoff value of 4.8 L min, was found to be interchangeable with the thermodilution method for >95% of measurements. Modelflow had a higher interchangeability rate compared to Hemac (93% vs 86%; P = .022) or other monitors (Wesseling cZ = 76%, LiDCO = 73%, and PiCCO = 62%; P < .0001). Simulated data and reanalysis of a data set comparing 5 CO monitors against thermodilution CO showed that, depending on the repeatability of the reference method, the interchangeability rate combined with a cutoff value could be used to define the range of values over which interchangeability remains acceptable.

  20. High-Intensity Interval Training Increases Cardiac Output and V˙O2max.

    Science.gov (United States)

    Astorino, Todd A; Edmunds, Ross M; Clark, Amy; King, Leesa; Gallant, Rachael A; Namm, Samantha; Fischer, Anthony; Wood, Kimi M

    2017-02-01

    Increases in maximal oxygen uptake (V˙O2max) frequently occur with high-intensity interval training (HIIT), yet the specific adaptation explaining this result remains elusive. This study examined changes in V˙O2max and cardiac output (CO) in response to periodized HIIT. Thirty-nine active men and women (mean age and V˙O2max = 22.9 ± 5.4 yr and 39.6 ± 5.6 mL·kg·min) performed HIIT and 32 men and women (age and V˙O2max = 25.7 ± 4.5 yr and 40.7 ± 5.2 mL·kg·min) were nonexercising controls (CON). The first 10 sessions of HIIT required eight to ten 60 s bouts of cycling at 90%-110% percent peak power output interspersed with 75 s recovery, followed by randomization to one of three regimes (sprint interval training (SIT), high-volume interval training (HIITHI), or periodized interval training (PER) for the subsequent 10 sessions. Before, midway, and at the end of training, progressive cycling to exhaustion was completed during which V˙O2max and maximal CO were estimated. Compared with CON, significant (P HIIT + SIT (39.8 ± 7.3 mL·kg·min to 43.6 ± 6.1 mL·kg·min), HIIT + HIITHI (41.1 ± 4.9 mL·kg·min to 44.6 ± 7.0 mL·kg·min), and HIIT + PER (39.5 ± 5.6 mL·kg·min to 44.1 ± 5.4 mL·kg·min) occurred which were mediated by significant increases in maximal CO (20.0 ± 3.1 L·min to 21.7 ± 3.2 L·min, P = 0.04). Maximal stroke volume was increased with HIIT (P = 0.04), although there was no change in maximal HR (P = 0.88) or arteriovenous O2 difference (P = 0.36). These CO data are accurate and represent the mean changes from pre- to post-HIIT across all three training groups. Increases in V˙O2max exhibited in response to different HIIT regimes are due to improvements in oxygen delivery.

  1. Invasive hemodynamic monitoring in the postoperative period of cardiac surgery

    Directory of Open Access Journals (Sweden)

    Desanka Dragosavac

    1999-08-01

    Full Text Available OBJETIVE: To assess the hemodynamic profile of cardiac surgery patients with circulatory instability in the early postoperative period (POP. METHODS: Over a two-year period, 306 patients underwent cardiac surgery. Thirty had hemodynamic instability in the early POP and were monitored with the Swan-Ganz catheter. The following parameters were evaluated: cardiac index (CI, systemic and pulmonary vascular resistance, pulmonary shunt, central venous pressure (CVP, pulmonary capillary wedge pressure (PCWP, oxygen delivery and consumption, use of vasoactive drugs and of circulatory support. RESULTS: Twenty patients had low cardiac index (CI, and 10 had normal or high CI. Systemic vascular resistance was decreased in 11 patients. There was no correlation between oxygen delivery (DO2 and consumption (VO2, p=0.42, and no correlation between CVP and PCWP, p=0.065. Pulmonary vascular resistance was decreased in 15 patients and the pulmonary shunt was increased in 19. Two patients with CI < 2L/min/m² received circulatory support. CONCLUSION: Patients in the POP of cardiac surgery frequently have a mixed shock due to the systemic inflammatory response syndrome (SIRS. Therefore, invasive hemodynamic monitoring is useful in handling blood volume, choice of vasoactive drugs, and indication for circulatory support.

  2. Predictors of Post Pericardiotomy Low Cardiac Output Syndrome in Patients With Pericardial Effusion

    Directory of Open Access Journals (Sweden)

    Sabzi Feridoun

    2015-03-01

    Full Text Available Introduction: Pathological involvement of pericardium by any disease that resulting in effusion may require decompression and pericardiectomy. The current article describes rare patients with effusion who after pericadiectomy and transient hemodynamic improvement rapidly developed progressive heart failure and subsequent multi organ failure.Methods: During periods of five years, 423 patients in our hospital underwent pericardiotomy for decompression of effusion. The clinical characteristics of those patient with postoperative low cardiac output (B group (14 cases recorded and compared with other patients without this postoperative complication (A group by test and X2. Significant variables in invariables (P≤0.1 entered in logistic regression analysis and odd ratio of these significant variables obtained. Results: Idiopathic pericardial effusion, malignancy, renal failure, connective tissue disease, viral pericarditis was found in 125 patients (27%, 105 patients (25.4%, 65 patients (15.6%, 50 (17.1% and 10 (2.4% of patients subsequently. The factors that predict post-operative death in logistic regression analysis were malignancy, radiotherapy, constrictive pericarditis inotropic drug using IABP using, pre-operative EF and pericardial calcification.Conclusion: Certain preoperative variables such as malignancy, radiotherapy, low EF, calcified pericardium and connective tissue disease are associated with POLCOS and post-operative risk of death. This paradoxical response to pericardial decompression may be more frequent than currently appreciated. Its cause may relate to the sudden removal of the chronic external ventricular support from the effusion or thicken pericardium resulting in ventricular dilatation and failure or intra operative myocardial injury due to pericardiectomy of calcified pericardium, radiation and cardiomyopathy.

  3. Omega-3 fatty acid supplementation enhances stroke volume and cardiac output during dynamic exercise.

    Science.gov (United States)

    Walser, Buddy; Stebbins, Charles L

    2008-10-01

    Docosahexaenoic acid (DHA) and eicosapentaenoic acid (EPA) have beneficial effects on cardiovascular function. We tested the hypotheses that dietary supplementation with DHA (2 g/day) + EPA (3 g/day) enhances increases in stroke volume (SV) and cardiac output (CO) and decreases in systemic vascular resistance (SVR) during dynamic exercise. Healthy subjects received DHA + EPA (eight men, four women) or safflower oil (six men, three women) for 6 weeks. Both groups performed 20 min of bicycle exercise (10 min each at a low and moderate work intensity) before and after DHA + EPA or safflower oil treatment. Mean arterial pressure (MAP), heart rate (HR), SV, CO, and SVR were assessed before exercise and during both workloads. HR was unaffected by DHA + EPA and MAP was reduced, but only at rest (88 +/- 5 vs. 83 +/- 4 mm Hg). DHA + EPA augmented increases in SV (14.1 +/- 6.3 vs. 32.3 +/- 8.7 ml) and CO (8.5 +/- 1.0 vs. 10.3 +/- 1.2 L/min) and tended to attenuate decreases in SVR (-7.0 +/- 0.6 vs. -10.1 +/- 1.6 mm Hg L(-1) min(-1)) during the moderate workload. Safflower oil treatment had no effects on MAP, HR, SV, CO or SVR at rest or during exercise. DHA + EPA-induced increases in SV and CO imply that dietary supplementation with these fatty acids can increase oxygen delivery during exercise, which may have beneficial clinical implications for individuals with cardiovascular disease and reduced exercise tolerance.

  4. The effect of halothane on the distribution of cardiac output and organ blood flows in the hemorrhagic, hypotensive dog

    International Nuclear Information System (INIS)

    Ahlgren, I.; Aronsen, K.F.; Bjoerkman, I.

    1978-01-01

    Halothane was given to dogs which had been bled to an arterial mean blood pressure of 60 mmHg, and the circulatory effects were studied with the aid of the radioactive microsphere technique. The cardiac output and coronary blood flow were well maintained, whereas the arterial mean blood pressure was slightly, and the stroke volume markedly increased, indicating an improved heart function. The blood flows to the brain, lungs, liver and kidneys were well preserved throughout the anesthesia. The effect of retransfusing the withdrawn blood was also studied, and it resulted in an increased cardiac output, arterial mean blood pressure and increased blood flows to the heart, lungs, spleen, bowel and liver. (author)

  5. Effect of heat stress on cardiac output and systemic vascular conductance during simulated hemorrhage to presyncope in young men

    DEFF Research Database (Denmark)

    Ganio, Matthew S; Overgaard, Morten; Seifert, Thomas

    2012-01-01

    During moderate actual or simulated hemorrhage, as cardiac output decreases, reductions in systemic vascular conductance (SVC) maintain mean arterial pressure (MAP). Heat stress, however, compromises the control of MAP during simulated hemorrhage, and it remains unknown whether this response is due...... to a persistently high SVC and/or a low cardiac output. This study tested the hypothesis that an inadequate decrease in SVC is the primary contributing mechanism by which heat stress compromises blood pressure control during simulated hemorrhage. Simulated hemorrhage was imposed via lower body negative pressure...... normothermic is no longer adequate during a heat-stressed-simulated hemorrhage. The absence of a decrease in SVC at a time of profound reductions in MAP suggests that inadequate control of vascular conductance is a primary mechanism compromising blood pressure control during these conditions....

  6. Study on cardiac output in children with orthostatic disturbances measured by the external dilution method with a radioisotope

    Energy Technology Data Exchange (ETDEWEB)

    Hattori, K [Nippon Medical School, Tokyo

    1975-04-01

    As one of the studies on circulation dynamics which possibly contributed to orthostatic disturbance, application to children of the external measurement of cardiac output with /sup 131/I labeled human serum albumin was examined. The effect of orthostatic load was then studied by this method on the children with orthostatic disturbances and the patients improving from other diseases, and the following results were obtained: (1) As in the external method with radioisotope, the head of the scintillation detector was easily oriented, and the diversion of orientation was examined by circulation dilution curve, and the cardiac output was easily and safely measured without causing severe pain to the subjects. This method was performed on 40 children in the recumbent position and 27 in orthostatic load, and it was confirmed that the method was fully applicable to the pediatric field. (2) In half of the 20 patients with orthostatic disturbances and 20 control subjects, the cardiac index in the recumbent position was between 3 l/min/m/sup 2/ and 5 l/min/m/sup 2/. Mean cardiac index was 4.45 l/min/m/sup 2/ in male children, while 4.72 l/min/m/sup 2/ in female children. This mean value was the same or a little higher than the reported adult value.

  7. Ubiquitous computing for remote cardiac patient monitoring: a survey.

    Science.gov (United States)

    Kumar, Sunil; Kambhatla, Kashyap; Hu, Fei; Lifson, Mark; Xiao, Yang

    2008-01-01

    New wireless technologies, such as wireless LAN and sensor networks, for telecardiology purposes give new possibilities for monitoring vital parameters with wearable biomedical sensors, and give patients the freedom to be mobile and still be under continuous monitoring and thereby better quality of patient care. This paper will detail the architecture and quality-of-service (QoS) characteristics in integrated wireless telecardiology platforms. It will also discuss the current promising hardware/software platforms for wireless cardiac monitoring. The design methodology and challenges are provided for realistic implementation.

  8. Monitor of cardiac events implemented in PDA platform

    International Nuclear Information System (INIS)

    Bustamante, John; Saenz, Jose F; Amaya, Adrian

    2007-01-01

    Ambulatory monitoring of electrocardiac events constitutes a valuable tool in the diagnosis of cardiac arrhythmias involved in pathologic processes such as myocardiopathies, post-infarction stages, autonomous cardiac system injuries, etc.; unfortunately, its extensive use is not possible yet, due to the high costs that imply the acquisition of these equipment. For this purpose, through the utilization of personal digital assistants, a monitor of cardiac events with pre and post-symptomatic recording capacity, electrocardiographic signal visualization in real time, automatic recording of bradycardias and tachycardias and the possibility of annotation of symptoms by the patient, is designed and developed. It consists of a hardware component for the acquisition and treatment of the signals, software for the monitoring in Palm OSO platform and an appliance for the discharge and analysis of the stored data. Prototype validations were realized through an electrocardiographic simulator, an arrhythmia simulator Based on arrhythmia data base registers of the Massachusetts Institute of Technology and 8eth Israel Hospital and on pilot tests of healthy people and of patients with arrhythmias. In this preliminary report, we show the way in which the developed prototype constitutes a viable alternative for ambulatory monitoring of arrhythmia, taking advantages of the storage capacity, processing and visualization that have the actual digital assistances with the additional advantages that its use is not restricted to only one utility and its economic accessibility is facilitated due to its wide commercial availability

  9. Does obesity affect the non-invasive measurement of cardiac output performed by electrical cardiometry in children and adolescents?

    Science.gov (United States)

    Altamirano-Diaz, Luis; Welisch, Eva; Rauch, Ralf; Miller, Michael; Park, Teresa Sohee; Norozi, Kambiz

    2018-02-01

    Electrical cardiometry (EC) is a non-invasive and inexpensive method for hemodynamic assessment and monitoring. However, its feasibility for widespread clinical use, especially for the obese population, has yet to be determined. In this study, we evaluated the agreement and reliability of EC compared to transthoracic Doppler echocardiography (TTE) in normal, overweight, and obese children and adolescents. We measured stroke volume (SV) and cardiac output (CO) of 131 participants using EC and TTE simultaneously. We further divided these participants according to BMI percentiles for subanalyses: 95% obese (n = 83). Due to small sample size of the overweight group, we combined overweight and obese groups (OW+OB) with no significant change in results (SV and CO) before and after combining groups. There were strong correlations between EC and TTE measurements of SV (r = 0.869 and r = 0.846; p < 0.0001) and CO (r = 0.831 and r = 0.815; p < 0.0001) in normal and OW+OB groups, respectively. Bias and percentage error for CO measurements were 0.240 and 29.7%, and 0.042 and 29.5% in the normal and OW+OB groups, respectively. Indexed values for SV were lower in the OW+OB group than in the normal weight group when measured by EC (p < 0.0001) but no differences were seen when measured by TTE (p = 0.096). In all weight groups, there were strong correlations and good agreement between EC and TTE. However, EC may underestimate hemodynamic measurements in obese participants due to fat tissue.

  10. Use of transesophageal Doppler ultrasonography in ventilated pediatric patients: derivation of cardiac output.

    Science.gov (United States)

    Tibby, S M; Hatherill, M; Murdoch, I A

    2000-06-01

    To ascertain if cardiac output (CO) could be derived from blood flow velocity measured in the descending aorta of ventilated children by transesophageal Doppler ultrasonography (TED) without the need for direct aortic cross sectional area measurement, and to evaluate the ability of TED to follow changes in CO when compared with femoral artery thermodilution. Prospective, comparison study. A 16-bed pediatric intensive care unit of a university hospital. A total of 100 ventilated infants and children aged 4 days to 18 yrs (median age, 27 months). Diagnoses included postcardiac surgery (n = 58), sepsis/multiple organ failure (n = 32), respiratory disease (n = 5), and other (n = 5). A total of 55 patients were receiving inotropes or vasodilators. When patients were hemodynamically stable, a TED probe was placed into the distal esophagus to obtain optimal signal, and minute distance (MD) was recorded. Five consecutive MD measurements were made concurrently with five femoral artery thermodilution measurements, and the concurrent measurements were averaged. CO was then manipulated by fluid administration or inotrope adjustment, and the readings were repeated. Femoral artery thermodilution CO ranged from 0.32 to 9.19 L/min, (median, 2.46 L/min), and encompassed a wide range of high and low flow states. Theoretical consideration revealed the optimal TED estimate for CO to be (MD x patient height2 x 10(-7)). Linear regression analysis yielded a power function model such that: estimated CO = 1.158 x (MD x height2 x 10(-7))(0.785), r2 = 0.879, standard error of the estimate = 0.266. Inclusion of a correction factor for potential changes in aortic cross-sectional area with hypo- and hypertension did not appreciably improve the predictive value of the model. MD was able to follow percentage changes in CO, giving a mean bias of 0.87% (95% confidence interval -0.85% to 2.59%), and limits of agreement of +/- 16.82%. The median coefficient of variation for MD was 3.3%. TED provides

  11. Effect of hemorrhage on cardiac output, vasopressin, aldosterone, and diuresis during immersion in men

    Science.gov (United States)

    Greenleaf, J. E.; Simanonok, K.; Bernauer, E. M.; Wade, C. E.; Keil, L. C.

    1992-01-01

    The purpose of this research was to test the hypotesis that a reduction in blood volume would attenuate or eliminate immersion-induced increases in cardiac output (Q(sub co)) and urine excretion, and to investigate accompanying vasoactive and fluid-electrolyte hormonal responses. Eight men (19-23 yr) were supine during a 2-hr control period in air, and then sat for 5-hr test periods in air at 20 C (dry control, DC); water at 34.5 C (wet control, WC); and water (34.5 C) after hemorrhage (WH) of 14.8 plus or minus 0.3 percent of their blood volume. Blood volume was -11.6 plus or minus 0.6 percent at immersion (time 0). Mean (bar-X hrs 1-5) Q(sub co) was unchanged in WC (5.3 plus or minus 0.01 l/min) and in WH (4.5 plus or minus 0.1 l/min), but decreased (P less than 0.05) in DC to 3.6 plus or minus 0.1 l/min. Mean urine excretion rates were 1.0 plus or minus 0.2 ml/min for DC and 1.1 plus or minus 0.2 ml/min for WH; both were lower (P less than 0.05) than that for WC of 2.0 plus or minus 0.4 ml/min. Plasma (Na+) and (Osm) were unchanged in all experiments. Mean plasma vasopressin (PVP) (bar-X hrs 1-5) was 1.1 plus or minus 0.1 pg/ml in WC, and higher (P less than 0.05) in DC (2.1 plus or minus 0.2 pg/ml)and WH (2.1 plus or minus 0.1 pg/ml); it was unchanged during air and water test periods. Thus, hemorrhage attenuated the immersion-induced increase in Q(sub co), eliminated the WC diuresis, maintained plasma renin activity and PVP at DC levels and did not change immersion-induced aldosterone suppression; the osmotic diuresis during control immersion is apparently not due to either aldosterone suppression or vasopressin suppression.

  12. Design of a continuous digital-output environmental radon monitor

    International Nuclear Information System (INIS)

    Wrenn, M.E.; Spitz, H.; Cohen, N.

    1975-01-01

    A new field instrument for the continuous measurement of radon concentrations has been developed to investigate the magnitude and variability of environmental levels of 222 Rn. Passive diffusion of radon, but not its daughters, occurs through an open pore polyurethane foam into a sensitive volume where a static electric field directs the positively ionized radon daughter products to a central collecting electrode. Pulses in a ZnS(Ag) scintillator, resulting from the alpha emission of 218 Po and 214 Po, are observed with a photomultiplier tube and counted using standard NIM electronics. The detector unit has been fabricated into a small, convenient package for indoor air sampling without the use of air movers or pumps. The unit is unobtrusive and acceptable into a daily routine without disrupting normal family or business activities. The monitor can detect as little as 0.5 pCi/l for a 40-min. count (α = .05). The equilibrium detection efficiency of the instrument is 0.7 cpm/pCi/l. (U.S.)

  13. Low cardiac output predicts development of hepatorenal syndrome and survival in patients with cirrhosis and ascites

    DEFF Research Database (Denmark)

    Krag, A; Bendtsen, F; Møller, S

    2010-01-01

    (130 (SD 46) vs 78 (SD 29) mumol/l, psyndrome type 1 within 3 months was higher in the group with low CI than in the high CI group (43% vs 5%, p = 0.04). Patients with the lowest CI (N = 8) had significantly poorer survival at 3, 9, and 12 months......OBJECTIVES: Recent studies suggest that cardiac dysfunction precedes development of the hepatorenal syndrome. In this follow-up study, we aimed to investigate the relation between cardiac and renal function in patients with cirrhosis and ascites and the impact of cardiac systolic function...

  14. Electrocardiographic Patch Devices and Contemporary Wireless Cardiac Monitoring

    Directory of Open Access Journals (Sweden)

    Erik eFung

    2015-05-01

    Full Text Available Cardiac electrophysiologic derangements often coexist with disorders of the circulatory system. Capturing and diagnosing arrhythmias and conduction system disease may lead to a change in diagnosis, clinical management and patient outcomes. Standard 12-lead electrocardiogram (ECG, Holter monitors and event recorders have served as useful diagnostic tools over the last few decades. However, their shortcomings are only recently being addressed by emerging technologies. With advances in device miniaturization and wireless technologies, and changing consumer expectations, wearable ‘on-body’ ECG patch devices have evolved to meet contemporary needs. These devices are unobtrusive and easy to use, leading to increased device wear time and diagnostic yield. While becoming the standard for detecting arrhythmias and conduction system disorders in the outpatient setting where continuous ECG monitoring in the short to medium term (days to weeks is indicated, these cardiac devices and related digital mobile health technologies are reshaping the clinician-patient interface with important implications for future healthcare delivery.

  15. Low cardiac output as physiological phenomenon in hibernating, free-ranging Scandinavian brown bears (Ursus arctos) - an observational study.

    Science.gov (United States)

    Jørgensen, Peter Godsk; Arnemo, Jon; Swenson, Jon E; Jensen, Jan S; Galatius, Søren; Frøbert, Ole

    2014-09-16

    Despite 5-7 months of physical inactivity during hibernation, brown bears (Ursus arctos) are able to cope with physiological conditions that would be detrimental to humans. During hibernation, the tissue metabolic demands fall to 25% of the active state. Our objective was to assess cardiac function associated with metabolic depression in the hibernating vs. active states in free-ranging Scandinavian brown bears. We performed echocardiography on seven free-ranging brown bears in Dalarna, Sweden, anesthetized with medetomidine-zolazepam-tiletamine-ketamine during winter hibernation in February 2013 and with medetomidine-zolazepam-tiletamine during active state in June 2013. We measured cardiac output noninvasively using estimates of hemodynamics obtained by pulsed wave Doppler echocardiography and 2D imaging. Comparisons were made using paired T-tests. During hibernation, all hemodynamic indices were significantly decreased (hibernating vs. active state): mean heart rate was 26.0 (standard deviation (SD): 5.6) beats per min vs. 75.0 (SD: 17.1) per min (P=0.002), mean stroke volume 32.3 (SD: 5.2) ml vs. 47.1 (SD: 7.9) ml (P=0.008), mean cardiac output 0.86 (SD: 0.31) l/min vs. 3.54 (SD: 1.04) l/min (P=0.003), and mean cardiac index 0.63 (SD: 0.21) l/min/kg vs. 2.45 (SD: 0.52) l/min/ m2 (Pbears during hibernation, despite the absence of atrial arrhythmias and valvular disease. Free-ranging brown bears demonstrate hemodynamics comparable to humans during active state, whereas during hibernation, we documented extremely low-flow hemodynamics. Understanding these physiological changes in bears may help to gain insight into the mechanisms of cardiogenic shock and heart failure in humans.

  16. Correction of time resolution of an ambulatory cardiac monitor (VEST)

    International Nuclear Information System (INIS)

    Kumita, Shin-ichiro; Nishimura, Tsunehiko; Hayashida, Kohei; Uehara, Toshiisa

    1990-01-01

    Using ambulatory cardiac monitor (VEST) at exercise study, its time resolution is very important factor. We evaluated the time resolution of VEST using pulsate cardiac baloon phantom. Four analysis were carried out; no smoothing (NS) method, 3 points smoothing (3S) method, short sampling interval (SS) method, and digital filter (DF) method. By comparison of |ΔEF| (|EF:HR120-EF: HR60|) among 4 analysis methods, |ΔEF| by DF method was significant small (NS:3.58±3.01, 3S: 4.46±0.95, SS: 3.35±3.26, DF: 1.11±1.28%). We conclude that correction of time resolution by digital filter is necessary when we use VEST during exercise. (author)

  17. Reduced peripheral arterial blood flow with preserved cardiac output during submaximal bicycle exercise in elderly heart failure

    Directory of Open Access Journals (Sweden)

    Leng Xiaoyan

    2009-11-01

    Full Text Available Abstract Background Older heart failure (HF patients exhibit exercise intolerance during activities of daily living. We hypothesized that reduced lower extremity blood flow (LBF due to reduced forward cardiac output would contribute to submaximal exercise intolerance in older HF patients. Methods and Results Twelve HF patients both with preserved and reduced left ventricular ejection fraction (LVEF (aged 68 ± 10 years without large (aorta or medium sized (iliac or femoral artery vessel atherosclerosis, and 13 age and gender matched healthy volunteers underwent a sophisticated battery of assessments including a peak exercise oxygen consumption (peak VO2, b physical function, c cardiovascular magnetic resonance (CMR submaximal exercise measures of aortic and femoral arterial blood flow, and d determination of thigh muscle area. Peak VO2 was reduced in HF subjects (14 ± 3 ml/kg/min compared to healthy elderly subjects (20 ± 6 ml/kg/min (p = 0.01. Four-meter walk speed was 1.35 ± 0.24 m/sec in healthy elderly verses 0.98 ± 0.15 m/sec in HF subjects (p p ≤ 0.03. Conclusion During CMR submaximal bike exercise in the elderly with heart failure, mechanisms other than low cardiac output are responsible for reduced lower extremity blood flow.

  18. Influence of water immersion, water gymnastics and swimming on cardiac output in patients with heart failure.

    Science.gov (United States)

    Schmid, Jean-Paul; Noveanu, Markus; Morger, Cyrill; Gaillet, Raymond; Capoferri, Mauro; Anderegg, Matthias; Saner, Hugo

    2007-06-01

    Whole-body water immersion leads to a significant shift of blood from the periphery to the intrathoracic circulation, followed by an increase in central venous pressure and heart volume. In patients with severely reduced left ventricular function, this hydrostatically induced volume shift might overstrain the cardiovascular adaptive mechanisms and lead to cardiac decompensation. To assess the haemodynamic response to water immersion, gymnastics and swimming in patients with chronic heart failure (CHF). 10 patients with compensated CHF (62.9 (6.3) years, ejection fraction 31.5% (4.1%), peak oxygen consumption (Vo(2)) 19.4 (2.8) ml/kg/min), 10 patients with coronary artery disease (CAD) but preserved left ventricular function (57.2 (5.6) years, ejection fraction 63.9% (5.5%), peak Vo(2) 28 (6.3) ml/kg/min), and 10 healthy controls (32.8 (7.2) years, peak Vo(2) 45.6 (6) ml/kg/min) were examined. Haemodynamic response to thermoneutral (32 degrees C) water immersion and exercise was measured using a non-invasive foreign gas rebreathing method during stepwise water immersion, water gymnastics and swimming. Water immersion up to the chest increased cardiac index by 19% in controls, by 21% in patients with CAD and by 16% in patients with CHF. Although some patients with CHF showed a decrease of stroke volume during immersion, all subjects were able to increase cardiac index (by 87% in healthy subjects, by 77% in patients with CAD and by 53% in patients with CHF). Vo(2) during swimming was 9.7 (3.3) ml/kg/min in patients with CHF, 12.4 (3.5) ml/kg/min in patients with CAD and 13.9 (4) ml/kg/min in controls. Patients with severely reduced left ventricular function but stable clinical conditions and a minimal peak Vo(2) of at least 15 ml/kg/min during a symptom-limited exercise stress test tolerate water immersion and swimming in thermoneutral water well. Although cardiac index and Vo(2) are lower than in patients with CAD with preserved left ventricular function and controls

  19. STEM promotion through museum exhibits on cardiac monitoring & cardiac rhythm management.

    Science.gov (United States)

    Countryman, Jordan D; Dow, Douglas E

    2014-01-01

    Formal education in science, technology, engineering and math (STEM) does not successfully engage all of the students who have potential to become skilled in STEM activities and careers. Museum exhibits may be able to reach and engage a broader range of the public. STEM Exhibits that are both understandable and capture the imagination of viewers may contribute toward increased interest in STEM activities. One such topic for such an exhibit could be cardiac pacemakers and cardioverter defibrillators that sustain life. Although museums have existed for centuries, the available types of exhibit designs has dramatically increased in recent decades due to innovations in technology. Science and technology museums have especially taken advantage of the progression of exhibit design to developed new ways to communicate to their viewers. These novel presentation tools allow museums to more effectively convey to and engage viewers. This paper examines the techniques employed by museums in exhibits and considers the practices of several museums with exhibits related to cardiac monitoring (CM) and cardiac rhythm management (CRM).

  20. An Interoperable System toward Cardiac Risk Stratification from ECG Monitoring

    Directory of Open Access Journals (Sweden)

    Cristina Soguero-Ruiz

    2018-03-01

    Full Text Available Many indices have been proposed for cardiovascular risk stratification from electrocardiogram signal processing, still with limited use in clinical practice. We created a system integrating the clinical definition of cardiac risk subdomains from ECGs and the use of diverse signal processing techniques. Three subdomains were defined from the joint analysis of the technical and clinical viewpoints. One subdomain was devoted to demographic and clinical data. The other two subdomains were intended to obtain widely defined risk indices from ECG monitoring: a simple-domain (heart rate turbulence (HRT, and a complex-domain (heart rate variability (HRV. Data provided by the three subdomains allowed for the generation of alerts with different intensity and nature, as well as for the grouping and scrutinization of patients according to the established processing and risk-thresholding criteria. The implemented system was tested by connecting data from real-world in-hospital electronic health records and ECG monitoring by considering standards for syntactic (HL7 messages and semantic interoperability (archetypes based on CEN/ISO EN13606 and SNOMED-CT. The system was able to provide risk indices and to generate alerts in the health records to support decision-making. Overall, the system allows for the agile interaction of research and clinical practice in the Holter-ECG-based cardiac risk domain.

  1. An Interoperable System toward Cardiac Risk Stratification from ECG Monitoring

    Science.gov (United States)

    Mora-Jiménez, Inmaculada; Ramos-López, Javier; Quintanilla Fernández, Teresa; García-García, Antonio; Díez-Mazuela, Daniel; García-Alberola, Arcadi

    2018-01-01

    Many indices have been proposed for cardiovascular risk stratification from electrocardiogram signal processing, still with limited use in clinical practice. We created a system integrating the clinical definition of cardiac risk subdomains from ECGs and the use of diverse signal processing techniques. Three subdomains were defined from the joint analysis of the technical and clinical viewpoints. One subdomain was devoted to demographic and clinical data. The other two subdomains were intended to obtain widely defined risk indices from ECG monitoring: a simple-domain (heart rate turbulence (HRT)), and a complex-domain (heart rate variability (HRV)). Data provided by the three subdomains allowed for the generation of alerts with different intensity and nature, as well as for the grouping and scrutinization of patients according to the established processing and risk-thresholding criteria. The implemented system was tested by connecting data from real-world in-hospital electronic health records and ECG monitoring by considering standards for syntactic (HL7 messages) and semantic interoperability (archetypes based on CEN/ISO EN13606 and SNOMED-CT). The system was able to provide risk indices and to generate alerts in the health records to support decision-making. Overall, the system allows for the agile interaction of research and clinical practice in the Holter-ECG-based cardiac risk domain. PMID:29494497

  2. Plasma volume expansion does not increase maximal cardiac output or VO2 max in lowlanders acclimatized to altitude

    DEFF Research Database (Denmark)

    Calbet, José A L; Rådegran, Göran; Boushel, Robert Christopher

    2004-01-01

    liter of 6% dextran 70 (BV = 6.32 +/- 0.34 liters). PV expansion had no effect on Qmax, maximal O2 consumption (VO2), and exercise capacity. Despite maximal systemic O2 transport being reduced 19% due to hemodilution after PV expansion, whole body VO2 was maintained by greater systemic O2 extraction (P...... VO2 during exercise regardless of PV. Pulmonary ventilation, gas exchange, and acid-base balance were essentially unaffected by PV expansion. Sea......With altitude acclimatization, blood hemoglobin concentration increases while plasma volume (PV) and maximal cardiac output (Qmax) decrease. This investigation aimed to determine whether reduction of Qmax at altitude is due to low circulating blood volume (BV). Eight Danish lowlanders (3 females, 5...

  3. Do interindividual differences in cardiac output during submaximal exercise explain differences in exercising muscle oxygenation and ratings of perceived exertion?

    Science.gov (United States)

    Bentley, Robert F; Jones, Joshua H; Hirai, Daniel M; Zelt, Joel T; Giles, Matthew D; Raleigh, James P; Quadrilatero, Joe; Gurd, Brendon J; Neder, J Alberto; Tschakovsky, Michael E

    2018-01-01

    Considerable interindividual differences in the Q˙-V˙O2 relationship during exercise have been documented but implications for submaximal exercise tolerance have not been considered. We tested the hypothesis that these interindividual differences were associated with differences in exercising muscle deoxygenation and ratings of perceived exertion (RPE) across a range of submaximal exercise intensities. A total of 31 (21 ± 3 years) healthy recreationally active males performed an incremental exercise test to exhaustion 24 h following a resting muscle biopsy. Cardiac output (Q˙ L/min; inert gas rebreathe), oxygen uptake (V˙O2 L/min; breath-by-breath pulmonary gas exchange), quadriceps saturation (near infrared spectroscopy) and exercise tolerance (6-20; Borg Scale RPE) were measured. The Q˙-V˙O2 relationship from 40 to 160 W was used to partition individuals post hoc into higher (n = 10; 6.3 ± 0.4) versus lower (n = 10; 3.7 ± 0.4, P exercise (all P > 0.4). Lower cardiac responders had greater leg (P = 0.027) and whole body (P = 0.03) RPE only at 185 W, but this represented a higher %peak V˙O2 in lower cardiac responders (87 ± 15% vs. 66 ± 12%, P = 0.005). Substantially lower Q˙-V˙O2 in the lower responder group did not result in altered RPE or exercising muscle deoxygenation. This suggests substantial recruitment of blood flow redistribution in the lower responder group as part of protecting matching of exercising muscle oxygen delivery to demand. © 2018 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  4. Preferential cephalic redistribution of left ventricular cardiac output during therapeutic hypothermia for perinatal hypoxic-ischemic encephalopathy.

    Science.gov (United States)

    Hochwald, Ori; Jabr, Mohammad; Osiovich, Horacio; Miller, Steven P; McNamara, Patrick J; Lavoie, Pascal M

    2014-05-01

    To determine the relationship between left ventricular cardiac output (LVCO), superior vena cava (SVC) flow, and brain injury during whole-body therapeutic hypothermia. Sixteen newborns with moderate or severe hypoxic-ischemic encephalopathy were studied using echocardiography during and immediately after therapeutic hypothermia. Measures were also compared with 12 healthy newborns of similar postnatal age. Newborns undergoing therapeutic hypothermia also had cerebral magnetic resonance imaging as part of routine clinical care on postnatal day 3-4. LVCO was markedly reduced (mean ± SD 126 ± 38 mL/kg/min) during therapeutic hypothermia, whereas SVC flow was maintained within expected normal values (88 ± 27 mL/kg/min) such that SVC flow represented 70% of the LVCO. The reduction in LVCO during therapeutic hypothermia was mainly accounted by a reduction in heart rate (99 ± 13 vs 123 ± 17 beats/min; P newborns without brain injury (P = .013). Newborns with perinatal hypoxic-ischemic encephalopathy showed a preferential systemic-to-cerebral redistribution of cardiac blood flow during whole-body therapeutic hypothermia, which may reflect a lack of cerebral vascular adaptation in newborns with more severe brain injury. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Influence of heart motion on cardiac output estimation by means of electrical impedance tomography: a case study

    International Nuclear Information System (INIS)

    Proença, Martin; Braun, Fabian; Rapin, Michael; Solà, Josep; Lemay, Mathieu; Adler, Andy; Grychtol, Bartłomiej; Bohm, Stephan H; Thiran, Jean-Philippe

    2015-01-01

    Electrical impedance tomography (EIT) is a non-invasive imaging technique that can measure cardiac-related intra-thoracic impedance changes. EIT-based cardiac output estimation relies on the assumption that the amplitude of the impedance change in the ventricular region is representative of stroke volume (SV). However, other factors such as heart motion can significantly affect this ventricular impedance change. In the present case study, a magnetic resonance imaging-based dynamic bio-impedance model fitting the morphology of a single male subject was built. Simulations were performed to evaluate the contribution of heart motion and its influence on EIT-based SV estimation. Myocardial deformation was found to be the main contributor to the ventricular impedance change (56%). However, motion-induced impedance changes showed a strong correlation (r = 0.978) with left ventricular volume. We explained this by the quasi-incompressibility of blood and myocardium. As a result, EIT achieved excellent accuracy in estimating a wide range of simulated SV values (error distribution of 0.57 ± 2.19 ml (1.02 ± 2.62%) and correlation of r = 0.996 after a two-point calibration was applied to convert impedance values to millilitres). As the model was based on one single subject, the strong correlation found between motion-induced changes and ventricular volume remains to be verified in larger datasets. (paper)

  6. The novel application of Benford's second order analysis for monitoring radiation output in interventional radiology.

    Science.gov (United States)

    Cournane, S; Sheehy, N; Cooke, J

    2014-06-01

    Benford's law is an empirical observation which predicts the expected frequency of digits in naturally occurring datasets spanning multiple orders of magnitude, with the law having been most successfully applied as an audit tool in accountancy. This study investigated the sensitivity of the technique in identifying system output changes using simulated changes in interventional radiology Dose-Area-Product (DAP) data, with any deviations from Benford's distribution identified using z-statistics. The radiation output for interventional radiology X-ray equipment is monitored annually during quality control testing; however, for a considerable portion of the year an increased output of the system, potentially caused by engineering adjustments or spontaneous system faults may go unnoticed, leading to a potential increase in the radiation dose to patients. In normal operation recorded examination radiation outputs vary over multiple orders of magnitude rendering the application of normal statistics ineffective for detecting systematic changes in the output. In this work, the annual DAP datasets complied with Benford's first order law for first, second and combinations of the first and second digits. Further, a continuous 'rolling' second order technique was devised for trending simulated changes over shorter timescales. This distribution analysis, the first employment of the method for radiation output trending, detected significant changes simulated on the original data, proving the technique useful in this case. The potential is demonstrated for implementation of this novel analysis for monitoring and identifying change in suitable datasets for the purpose of system process control. Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  7. Measurement of cardiac output in children by pressure-recording analytical method.

    Science.gov (United States)

    Urbano, Javier; López, Jorge; González, Rafael; Solana, María José; Fernández, Sarah N; Bellón, José M; López-Herce, Jesús

    2015-02-01

    We evaluated two pressure-recording analytical method (PRAM) software versions (v.1 and v.2) to measure cardiac index (CI) in hemodynamically stable critically ill children and investigate factors that influence PRAM values. The working hypothesis was that PRAM CI measurements would stay within normal limits in hemodynamically stable patients. Ninety-five CI PRAM measurements were analyzed in 47 patients aged 1-168 months. Mean CI was 4.1 ± 1.4 L/min/m(2) (range 2.0-7.0). CI was outside limits defined as normal (3-5 L/min/m(2)) in 53.7% of measurements (47.8% with software v.1 and 69.2% with software v.2, p = 0.062). Moreover, 14.7% of measurements were below 2.5 L/min/m(2), and 13.6% were above 6 L/min/m(2). CI was significantly lower in patients with a clearly visible dicrotic notch than in those without (3.7 vs. 4.6 L/min/m(2), p = 0.004) and in children with a radial arterial catheter (3.5 L/min/m(2)) than in those with a brachial (4.4 L/min/m(2), p = 0.021) or femoral catheter (4.7 L/min/m(2), p = 0.005). By contrast, CI was significantly higher in children under 12 months (4.2 vs. 3.6 L/min/m(2), p = 0.034) and weighing under 10 kg (4.2 vs. 3.6 L/min/m(2), p = 0.026). No significant differences were observed between cardiac surgery patients and the rest of children. A high percentage of CI measurements registered by PRAM were outside normal limits in hemodynamically stable, critically ill children. CI measured by PRAM may be influenced by the age, weight, location of catheter, and presence of a dicrotic notch.

  8. [Design and application of user managing system of cardiac remote monitoring network].

    Science.gov (United States)

    Chen, Shouqiang; Zhang, Jianmin; Yuan, Feng; Gao, Haiqing

    2007-12-01

    According to inpatient records, data managing demand of cardiac remote monitoring network and computer, this software was designed with relative database ACCESS. Its interface, operational button and menu were designed in VBA language assistantly. Its design included collective design, amity, practicability and compatibility. Its function consisted of registering, inquiring, statisticing and printing, et al. It could be used to manage users effectively and could be helpful to exerting important action of cardiac remote monitoring network in preventing cardiac-vascular emergency ulteriorly.

  9. Monitoring the consistency of the dynalyser output via digital display unit and calculated practical peak voltage

    International Nuclear Information System (INIS)

    Wan Hazlinda Ismail; Muhammad Jamal Mohd Isa; Abdul Aziz Mohd Ramli; Shahrul Azlan Azizan

    2010-01-01

    This study was carried out to ensure the adequacy and accuracy of the Dynalyser Digital Display unit for measuring the true kVp from the invasive kVp meter unit during calibration of non-invasive kVp meters. An invasive high voltage divider (dynalyser) coupled to the x-ray system measures the true kilo voltage supplied to the x-ray tube. The kVp output measured was displayed via its digital display unit while its waveform was acquired using a calibrated oscilloscope. The waveform was used to calculate the Practical Peak Voltage (PPV) using the International Standard method adapted from IEC 61676 and treated as the true kVp value. The kVp output was measured at 9 points ranging between 40 kV-120 kV with interval steps of 10 kV and monitored every day. The test result was evaluated for variation of output, intrinsic error and limit of variation in compliance with the IEC standard. Results showed that kVp output measured by the display unit everyday is consistent with variations of not more than ±0.45 kV, intrinsic error of not more than ±0.009 kV and limits of variation of less than 1% which comply with the IEC standard requirement. The kVp output via digital display unit has a total uncertainty of not more than 2.8 kV (k=2) while the PPV output via oscilloscope has total uncertainty of not more than 0.75 kV (k=2). As a conclusion, the dynalyser digital display unit complies with standard requirement and can be used to measure the true kVp output during the calibration of non-invasive kVp meters. (author)

  10. Oral Consumption of Vitamin K2 for 8 Weeks Associated With Increased Maximal Cardiac Output During Exercise.

    Science.gov (United States)

    McFarlin, Brian K; Henning, Andrea L; Venable, Adam S

    2017-07-01

    Background • Vitamin K1 and K2 are not typically common in a Western diet because they are found in a variety of fermented foods. Vitamin K2 in particular has been demonstrated to restore mitochondrial function and has a key role in production of mitochondrial adenosine triphosphate. Thus, it is reasonable to speculate that dietary supplementation with vitamin K2 could increase the function of muscle with high mitochondrial content (ie, skeletal and cardiac muscle). Objective • The purpose of this study was to determine if 8 wk of dietary supplementation with Vitamin K2 could alter cardiovascular responses to a graded cycle ergometer test. Design • The study was a randomized controlled trial. Setting • The study took place in the Applied Physiology Laboratory of the Department of Biological Sciences at the University of North Texas (Denton, TX, USA). Participants • Participants were aerobically trained males and female athletes (N = 26). Intervention • Participants were randomly assigned either to a control group that received a rice flour placebo or to an intervention group that received vitamin K2. For weeks 1 to 4, participants received 300 mg/d; for weeks 5 to 8, they received 150 mg/d. Subjects assigned to the control group received similar doses to mirror the intervention group. Subjects consumed the supplements during an 8-wk period while they maintained their typical exercise habits. Outcome Measures • At baseline and postintervention, participants completed a standard, graded exercise test on an electronically braked cycle ergometer. Before the test, participants were fitted with a mouth piece, and their oxygen consumption, carbon dioxide production, respiratory rate, and respiratory exchange ratio were measured. In addition, participants were fitted with skin-mounted electrodes that measured noninvasive cardiac output, stroke volume, and heart rate. To assess the cumulative exercise change, an area-under-the-curve (AUC) value was calculated

  11. Increased cardiac output and maximal oxygen uptake in response to ten sessions of high intensity interval training.

    Science.gov (United States)

    Astorino, Todd A; Edmunds, Ross M; Clark, Amy; King, Leesa; Gallant, Rachael M; Namm, Samantha; Fischer, Anthony; Wood, Kimi A

    2018-01-01

    Increases in maximal oxygen uptake (VO2max) are widely reported in response to completion of high intensity interval training (HIIT), yet the mechanism explaining this result is poorly understood. This study examined changes in VO2max and cardiac output (CO) in response to 10 sessions of low-volume HIIT. Participants included 30 active men and women (mean age and VO2max=22.9±5.4 years and 39.6±5.6 mL/kg/min) who performed HIIT and 30 men and women (age and VO2max=25.7±4.5 years and 40.7±5.2 mL/kg/min) who served as non-exercising controls (CON). High intensity interval training consisted of 6-10 s bouts of cycling per session at 90-110 percent peak power output (PPO) interspersed with 75 s recovery. Before and after training, progressive cycling to exhaustion was completed during which CO, stroke volume (SV), and heart rate (HR) were estimated using thoracic impedance. To confirm VO2max attainment, a verification test was completed after progressive cycling at a work rate equal to 110%PPO. Data demonstrated significant improvements in VO2max (2.71±0.63 L/min to 2.86±0.63 L/min, Psessions of HIIT is due to improvements in oxygen delivery.

  12. Ubiquitous health monitoring and real-time cardiac arrhythmias detection: a case study.

    Science.gov (United States)

    Li, Jian; Zhou, Haiying; Zuo, Decheng; Hou, Kun-Mean; De Vaulx, Christophe

    2014-01-01

    As the symptoms and signs of heart diseases that cause sudden cardiac death, cardiac arrhythmia has attracted great attention. Due to limitations in time and space, traditional approaches to cardiac arrhythmias detection fail to provide a real-time continuous monitoring and testing service applicable in different environmental conditions. Integrated with the latest technologies in ECG (electrocardiograph) analysis and medical care, the pervasive computing technology makes possible the ubiquitous cardiac care services, and thus brings about new technical challenges, especially in the formation of cardiac care architecture and realization of the real-time automatic ECG detection algorithm dedicated to care devices. In this paper, a ubiquitous cardiac care prototype system is presented with its architecture framework well elaborated. This prototype system has been tested and evaluated in all the clinical-/home-/outdoor-care modes with a satisfactory performance in providing real-time continuous cardiac arrhythmias monitoring service unlimitedly adaptable in time and space.

  13. Engineered hybrid cardiac patches with multifunctional electronics for online monitoring and regulation of tissue function

    Science.gov (United States)

    Feiner, Ron; Engel, Leeya; Fleischer, Sharon; Malki, Maayan; Gal, Idan; Shapira, Assaf; Shacham-Diamand, Yosi; Dvir, Tal

    2016-06-01

    In cardiac tissue engineering approaches to treat myocardial infarction, cardiac cells are seeded within three-dimensional porous scaffolds to create functional cardiac patches. However, current cardiac patches do not allow for online monitoring and reporting of engineered-tissue performance, and do not interfere to deliver signals for patch activation or to enable its integration with the host. Here, we report an engineered cardiac patch that integrates cardiac cells with flexible, freestanding electronics and a 3D nanocomposite scaffold. The patch exhibited robust electronic properties, enabling the recording of cellular electrical activities and the on-demand provision of electrical stimulation for synchronizing cell contraction. We also show that electroactive polymers containing biological factors can be deposited on designated electrodes to release drugs in the patch microenvironment on demand. We expect that the integration of complex electronics within cardiac patches will eventually provide therapeutic control and regulation of cardiac function.

  14. Engineered hybrid cardiac patches with multifunctional electronics for online monitoring and regulation of tissue function

    Science.gov (United States)

    Feiner, Ron; Engel, Leeya; Fleischer, Sharon; Malki, Maayan; Gal, Idan; Shapira, Assaf; Shacham-Diamand, Yosi; Dvir, Tal

    2016-01-01

    In cardiac tissue engineering approaches to treat myocardial infarction, cardiac cells are seeded within three-dimensional porous scaffolds to create functional cardiac patches. However, current cardiac patches do not allow for online monitoring and reporting of engineered-tissue performance, and do not interfere to deliver signals for patch activation or to enable its integration with the host. Here, we report an engineered cardiac patch that integrates cardiac cells with flexible, free-standing electronics and a 3D nanocomposite scaffold. The patch exhibited robust electronic properties, enabling the recording of cellular electrical activities and the on-demand provision of electrical stimulation for synchronizing cell contraction. We also show that electroactive polymers containing biological factors can be deposited on designated electrodes to release drugs in the patch microenvironment on-demand. We expect that the integration of complex electronics within cardiac patches will eventually provide therapeutic control and regulation of cardiac function. PMID:26974408

  15. Cardiac output by Doppler echocardiography in the premature baboon: Comparison with radiolabeled microspheres

    International Nuclear Information System (INIS)

    Kinsella, J.P.; Morrow, W.R.; Gerstmann, D.R.; Taylor, A.F.; deLemos, R.A.

    1991-01-01

    Pulsed-Doppler echocardiography (PDE) is a useful noninvasive method for determining left ventricular output (LVO). However, despite increasingly widespread use in neonatal intensive care units, validation studies in prematures with cardiopulmonary disease are lacking. The purpose of this study was to compare radiolabeled microsphere (RLM) and PDE measurements of LVO, using the critically ill premature baboon as a model of the human neonate. Twenty-two paired RLM and PDE measurements of LVO were obtained in 14 animals between 3 and 24 h of age. Average PDE LVO was 152 ml/min/kg (range, 40-258 ml/min/kg) compared to 158 ml/min/kg (range, 67-278 ml/min/kg) measured by RLM. Linear regression analysis of the paired measurements showed good correlation with a slope near unity (gamma = 0.94x + 4.20, r = 0.91, SEE = 25.7 ml). The authors conclude that PDE determinations of LVO compare well with those measured by RLM in the premature baboon. PDE appears to provide a valid estimate of LVO and should be useful in human prematures with cardiopulmonary distress

  16. The Higher the Insulin Resistance the Lower the Cardiac Output in Men with Type 1 Diabetes During the Maximal Exercise Test.

    Science.gov (United States)

    Niedzwiecki, Pawel; Naskret, Dariusz; Pilacinski, Stanislaw; Pempera, Maciej; Uruska, Aleksandra; Adamska, Anna; Zozulinska-Ziolkiewicz, Dorota

    2017-06-01

    The aim of this study was to assess the hemodynamic parameters analyzed in bioimpedance cardiography during maximal exercise in patients with type 1 diabetes differing in insulin resistance. The study group consisted of 40 men with type 1 diabetes. Tissue sensitivity to insulin was assessed on the basis of the glucose disposal rate (GDR) analyzed during hyperinsulinemic-euglycemic clamp. Patients were divided into groups with GDR insulin sensitivity) and GDR ≥4.5 mg/kg/min (G2 group-higher insulin sensitivity). During the exercise test, the heart rate, systolic volume, cardiac output, cardiac index were measured by the impedance meter (PhysioFlow). Compared with the G2 group, the G1 group had a lower cardiac output (CO): during exercise 8.6 (IQR 7.7-10.0) versus 12.8 (IQR 10.8-13.7) L/min; P insulin resistance is associated with cardiac hemodynamic parameters assessed during and after exercise. The higher the insulin resistance the lower the cardiac output during maximal exercise in men with type 1 diabetes.

  17. Beat-by-beat analysis of cardiac output and blood pressure responses to short-term barostimulation in different body positions

    Science.gov (United States)

    Hildebrandt, Wulf; Schütze, Harald; Stegemann, J.

    Rapid quantification of the human baro-reflex control of heart rate has been achieved on a beat-by-beat basis using a neck-chamber with quick ECG-triggered pressure changes. Referring to recent findings on heart rate and stroke volume, the present study uses this technique to compare cardiac output as well as blood pressure changes in supine and upright position to investigate feedback effects and to confirm postural reflex modifications not revealed by RR-interval changes. A suction profile starting at +40 mmHg and running 7 steps of pressure decrease down to -65 mmHg was examined in 0° and 90° tilting position while beat-by-beat recordings were done of heart rate, stroke volume (impedance-cardiography) and blood pressure (Finapres tm) (n=16). The percentual heart rate decrease failed to be significantly different between positions. A suction-induced stroke volume increase led to a cardiac output almost maintained when supine and significantly increased when upright. A decrease in all blood pressure values was found during suction, except for systolic values in upright position which increased. Conclusively, (a) it is confirmed that different inotropy accounts for the seen gravitational effect on the cardiac output not represented by heart rate; (b) identical suction levels in different positions lead to different stimuli at the carotid receptor. This interference has to be considered in microgravity studies by beat-by-beat measurement of cardiac output and blood pressure.

  18. Continuous Glucose Monitoring in the Cardiac ICU: Current Use and Future Directions.

    Science.gov (United States)

    Scrimgeour, Laura A; Potz, Brittany A; Sellke, Frank W; Abid, M Ruhul

    2017-11-01

    Perioperative glucose control is highly important, particularly for patients undergoing cardiac surgery. Variable glucose levels before, during and after cardiac surgery lead to increased post-operative complications and patient mortality. [1] Current methods for intensive monitoring and treating hyperglycemia in the Intensive Care Unit (ICU) usually involve hourly glucose monitoring and continuous intravenous insulin infusions. With the advent of more accurate subcutaneous glucose monitoring systems, the role of improved glucose control with newer systems deserves consideration for widespread adoption.

  19. Benefit of neurophysiologic monitoring for pediatric cardiac surgery.

    Science.gov (United States)

    Austin, E H; Edmonds, H L; Auden, S M; Seremet, V; Niznik, G; Sehic, A; Sowell, M K; Cheppo, C D; Corlett, K M

    1997-11-01

    Pediatric patients undergoing repair of congenital cardiac abnormalities have a significant risk of an adverse neurologic event. Therefore this retrospective cohort study examined the potential benefit of interventions based on intraoperative neurophysiologic monitoring in decreasing both postoperative neurologic sequelae and length of hospital stay as a cost proxy. With informed parental consent approved by the institutional review board, electroencephalography, transcranial Doppler ultrasonic measurement of middle cerebral artery blood flow velocity, and transcranial near-infrared cerebral oximetry were monitored in 250 patients. An interventional algorithm was used to detect and correct specific deficiencies in cerebral perfusion or oxygenation or to increase cerebral tolerance to ischemia or hypoxia. Noteworthy changes in brain perfusion or metabolism were observed in 176 of 250 (70%) patients. Intervention that altered patient management was initially deemed appropriate in 130 of 176 (74%) patients with neurophysiologic changes. Obvious neurologic sequelae (i.e., seizure, movement, vision or speech disorder) occurred in five of 74 (7%) patients without noteworthy change, seven of 130 (6%) patients with intervention, and 12 of 46 (26%) patients without intervention (p = 0.001). Survivors' median length of stay was 6 days in the no-change and intervention groups but 9 days in the no-intervention group. In addition, the percentage of patients in the no-intervention group discharged from the hospital within 1 week (32%) was significantly less than that in either the intervention (51%, p = 0.05) or no-change (58%, p = 0.01) groups. On the basis of an estimated hospital neurologic complication cost of $1500 per day, break-even analysis justified a hospital expenditure for neurophysiologic monitoring of $2142 per case. Interventions based on neurophysiologic monitoring appear to decrease the incidence of postoperative neurologic sequelae and reduce the length of stay

  20. Cardiac output-based fluid optimization for kidney transplant recipients: a proof-of-concept trial.

    Science.gov (United States)

    Corbella, Davide; Toppin, Patrick Jason; Ghanekar, Anand; Ayach, Nour; Schiff, Jeffery; Van Rensburg, Adrian; McCluskey, Stuart A

    2018-04-10

    Intravenous fluid management for deceased donor kidney transplantation is an important, modifiable risk factor for delayed graft function (DGF). The primary objective of this study was to determine if goal-directed fluid therapy using esophageal Doppler monitoring (EDM) to optimize stroke volume (SV) would alter the amount of fluid given. This randomized, proof-of-concept trial enrolled 50 deceased donor renal transplant recipients. Data collected included patient characteristics, fluid administration, hemodynamics, and complications. The EDM was used to optimize SV in the EDM group. In the control group, fluid management followed the current standard of practice. The groups were compared for the primary outcome of total intraoperative fluid administered. There was no difference in the mean (standard deviation) volume of intraoperative fluid administered to the 24 control and 26 EDM patients [2,307 (750) mL vs 2,675 (842) mL, respectively; mean difference, 368 mL; 95% confidence interval (CI), - 87 to + 823; P = 0.11]. The incidence of complications in the control and EDM groups was similar (15/24 vs 17/26, respectively; P = 0.99), as was the incidence of delayed graft failure (8/24 vs 11/26, respectively; P = 0.36). Goal-directed fluid therapy did not alter the volume of fluid administered or the incidence of complications. This proof-of-concept trial provides needed data for conducting a larger trial to determine the influence of fluid therapy on the incidence in DGF in deceased donor kidney transplantation. www.clinicaltrials.gov (NCT02512731). Registered 31 July 2015.

  1. Prophylactic milrinone for the prevention of low cardiac output syndrome and mortality in children undergoing surgery for congenital heart disease.

    Science.gov (United States)

    Burkhardt, Barbara E U; Rücker, Gerta; Stiller, Brigitte

    2015-03-25

    Children with congenital heart disease often undergo heart surgery at a young age. They are at risk for postoperative low cardiac output syndrome (LCOS) or death. Milrinone may be used to provide inotropic and vasodilatory support during the immediate postoperative period. This review examines the effectiveness of prophylactic postoperative use of milrinone to prevent LCOS or death in children having undergone surgery for congenital heart disease. Electronic and manual literature searches were performed to identify randomised controlled trials. We searched CENTRAL, MEDLINE, EMBASE and Web of Science in February 2014 and conducted a top-up search in September 2014 as well as clinical trial registries and reference lists of published studies. We did not apply any language restrictions. Only randomised controlled trials were selected for analysis. We considered studies with newborn infants, infants, toddlers, and children up to 12 years of age. Two review authors independently extracted data according to a pre-defined protocol. We obtained additional information from all study authors. Three of the five included studies compared milrinone versus levosimendan, one study compared milrinone with placebo, and one compared milrinone verus dobutamine, with 101, 242, and 50 participants, respectively. Three trials were at low risk of bias while two were at higher risk of bias. The number and definitions of outcomes were non-uniform as well. In one study comparing two doses of milrinone and placebo, there was some evidence in an overall comparison of milrinone versus placebo that milrinone lowered risk for LCOS (risk ratio (RR) 0.52, 95% confidence interval (CI) 0.28 to 0.96; 227 participants). The results from two small studies do not provide enough information to determine whether milrinone increases the risk of LCOS when compared to levosimendan (RR 1.22, 95% CI 0.32 to 4.65; 59 participants). Mortality rates in the studies were low, and there was insufficient evidence to

  2. Diesel Exhaust Inhalation Increases Cardiac Output, Bradyarrhythmias, and Parasympathetic Tone in Aged Heart Failure-Prone Rats

    Science.gov (United States)

    Acute air pollutant inhalation is linked to adverse cardiac events and death, and hospitalizations for heart failure. Diesel exhaust (DE) is a major air pollutant suspected to exacerbate preexisting cardiac conditions, in part, through autonomic and electrophysiologic disturbance...

  3. A New Device to Automate the Monitoring of Critical Patients’ Urine Output

    Directory of Open Access Journals (Sweden)

    Abraham Otero

    2014-01-01

    Full Text Available Urine output (UO is usually measured manually each hour in acutely ill patients. This task consumes a substantial amount of time. Furthermore, in the literature there is evidence that more frequent (minute-by-minute UO measurement could impact clinical decision making and improve patient outcomes. However, it is not feasible to manually take minute-by-minute UO measurements. A device capable of automatically monitoring UO could save precious time of the healthcare staff and improve patient outcomes through a more precise and continuous monitoring of this parameter. This paper presents a device capable of automatically monitoring UO. It provides minute by minute measures and it can generate alarms that warn of deviations from therapeutic goals. It uses a capacitive sensor for the measurement of the UO collected within a rigid container. When the container is full, it automatically empties without requiring any internal or external power supply or any intervention by the nursing staff. In vitro tests have been conducted to verify the proper operation and accuracy in the measures of the device. These tests confirm the viability of the device to automate the monitoring of UO.

  4. Current and Emerging Uses of Insertable Cardiac Monitors: Evaluation of Syncope and Monitoring for Atrial Fibrillation.

    Science.gov (United States)

    Tomson, Todd T; Passman, Rod

    Insertable cardiac monitors (ICMs) have provided clinicians with a superb tool for assessing infrequent or potentially asymptomatic arrhythmias. ICMs have shown their usefulness in the evaluation of unexplained syncope, providing high diagnostic yields in a cost-effective manner. While unexplained syncope continues to be the most common reason for their use, ICMs are increasingly being used for the monitoring of atrial fibrillation (AF). Recent trials have demonstrated that a substantial proportion of patients with cryptogenic stroke have AF detected only by the prolonged monitoring provided by ICMs. A particularly promising and emerging use for ICMs is in the management of anticoagulation in patients with known paroxysmal AF. The introduction in recent years of ICMs with automatic AF detection algorithms and continuous remote monitoring in combination with novel oral anticoagulants have opened the door for targeted anticoagulation guided by remote monitoring, a strategy that has recently shown promise in pilot studies of this technique. While further research is needed before official recommendations can be given, this use of ICMs opens exciting new possibilities for personalized medicine that could potentially reduce bleeding risk and improve quality of life in patients with atrial fibrillation.

  5. Implanted near-infrared spectroscopy for cardiac monitoring

    Science.gov (United States)

    Bhunia, Sourav K.; Cinbis, Can

    2011-02-01

    Implanted Cardioverter Defibrillator (ICD) provides one of the most effective therapies for the prevention of sudden cardiac death, but also delivers some high voltage shocks inappropriately, causing morbidity and mortality. Implanted near-infrared spectroscopy (NIRS) may augment ICD arrhythmia detection by monitoring skeletal muscle perfusion. A two-wavelength, single-distance, continuous-wave implanted NIRS has been evaluated in-vivo. A weighted difference of the changes in attenuation at two wavelengths, across the isobestic point of the hemoglobin spectra, was taken to be the microvascular oxygenation trend indicator (O2 Index). Although the exact weight depends on the local vascular distribution and their oxygen levels, the hypothesis that a constant weight may be adequate for hemodynamic trending during short arrhythmic episodes, was tested. The sensor was implanted subcutaneously both on fresh tissue and inside scar tissue that formed around a pre-existing implant, in 3 animals each. Attenuations were recorded at 660 and 890 nm during normal sinus rhythm (NSR) and induced ventricular fibrillation (VF). The slope of the O2 Index over 10 seconds was computed for 7 NSR and 8 VF episodes in fresh and 13 NSR and 15 VF episodes in scar tissue pockets. The mean O2 Index slope was significantly different (p<0.0001) between NSR and VF rhythms for both the fresh and scar tissue pockets. Therefore implanted NIRS may be useful for preventing inappropriate detection of VF during electromagnetic interference, double counting of ECG T-wave as an R-wave, ICD lead failure, electrocardiographic aberrancy etc.

  6. Monitor de eventos electrocardiacos implementado en plataforma PDA Monitor of cardiac events implemented in PDA platform

    Directory of Open Access Journals (Sweden)

    John Bustamante

    Full Text Available El monitoreo ambulatorio de eventos electrocardiacos es una herramienta valiosa en el diagnóstico de arritmias cardiacas, involucradas en procesos patológicos como miocardiopatías, estadios post-infarto, lesiones del sistema autónomo cardiaco, etc.; infortunadamente aún no es posible su uso extensivo debido a los altos costos que implica la adquisición de estos equipos. Con este propósito, se diseña y desarrolla mediante el uso de asistentes digitales personales, un monitor de eventos cardiacos con capacidad de grabación pre-sintomática y post-sintomática, visualización de señal electrocardiográfica en tiempo real, grabación automática de bradicardias y taquicardias, y posibilidad de anotación de síntomas por parte del paciente. Para ello se desarrolló un componente de hardware para la adquisición y tratamiento de las señales, un software para el monitoreo en plataforma Palm OS® y una aplicación para la descarga y análisis de los datos almacenados. Las validaciones del prototipo se realizaron mediante un simulador electrocardiográfico, un simulador de arritmias basado en registros de la base de datos de arritmias del Massachusetts Institute of Technology y Beth Israel Hospital, y pruebas piloto con personas sanas y pacientes con arritmias. En este reporte preliminar se enseña cómo el prototipo desarrollado, constituye una alternativa viable para el monitoreo ambulatorio de arritmias aprovechando las capacidades de almacenamiento, procesamiento y visualización con que cuentan los asistentes digitales actuales, con la ventaja adicional de que su uso no está restringido a una sola utilidad y su accesibilidad económica se facilita debido a su amplia disponibilidad comercial.Ambulatory monitoring of electro-cardiac events constitutes a valuable tool in the diagnosis of cardiac arrhythmias involved in pathologic processes such as myocardiopathies, post-infarction stages, autonomous cardiac system injuries, etc

  7. Decreased 2,3-diphosphoglycerate concentration in low cardiac output patients and its influence on the determination of in vivo p50.

    Science.gov (United States)

    Piccioni, Marilde A; Cestari, Idágene A; Strunz, Célia M C; Auler, José O

    2003-08-01

    We investigated whether 2,3-diphosphoglycerate (2,3-DPG) is altered in patients with low cardiac output and the influence of its concentration on the calculation of in vivo P(50). Biochemical and blood gas analysis were performed along with the measurement of cardiac output and body temperature in 13 patients submitted to cardiopulmonary bypass surgeries without the use of donor blood. In vivo P(50) was calculated using the measured (P(50m)) and the estimated 2,3-DPG (P(50e)). 2,3-DPG concentration was lower in these patients when compared to the values obtained in normal volunteers (6.9 +/- 2.2 vs. 11.9 +/- 2.4 microm/gHb). P(50m) was lower than P(50e) (21.6 +/- 1.1 vs. 30.1 +/- 1.2 mm Hg) at all time points. Our data show that in patients with low cardiac output, 2,3-DPG concentration is reduced. Therefore, in these patients, the use of standard values for this variable may introduce an error in the calculation of in vivo P(50).

  8. Change in end-tidal carbon dioxide outperforms other surrogates for change in cardiac output during fluid challenge.

    Science.gov (United States)

    Lakhal, K; Nay, M A; Kamel, T; Lortat-Jacob, B; Ehrmann, S; Rozec, B; Boulain, T

    2017-03-01

    During fluid challenge, volume expansion (VE)-induced increase in cardiac output (Δ VE CO) is seldom measured. In patients with shock undergoing strictly controlled mechanical ventilation and receiving VE, we assessed minimally invasive surrogates for Δ VE CO (by transthoracic echocardiography): fluid-induced increases in end-tidal carbon dioxide (Δ VE E'CO2 ); pulse (Δ VE PP), systolic (Δ VE SBP), and mean systemic blood pressure (Δ VE MBP); and femoral artery Doppler flow (Δ VE FemFlow). In the absence of arrhythmia, fluid-induced decrease in heart rate (Δ VE HR) and in pulse pressure respiratory variation (Δ VE PPV) were also evaluated. Areas under the receiver operating characteristic curves (AUC ROC s) reflect the ability to identify a response to VE (Δ VE CO ≥15%). In 86 patients, Δ VE E'CO2 had an AUC ROC =0.82 [interquartile range 0.73-0.90], significantly higher than the AUC ROC for Δ VE PP, Δ VE SBP, Δ VE MBP, and Δ VE FemFlow (AUC ROC =0.61-0.65, all P  1 mm Hg (>0.13 kPa) had good positive (5.0 [2.6-9.8]) and fair negative (0.29 [0.2-0.5]) likelihood ratios. The 16 patients with arrhythmia had similar relationships between Δ VE E'CO2 and Δ VE CO to patients with regular rhythm ( r 2 =0.23 in both subgroups). In 60 patients with no arrhythmia, Δ VE E'CO2 (AUC ROC =0.84 [0.72-0.92]) outperformed Δ VE HR (AUC ROC =0.52 [0.39-0.66], P AUC ROC =0.73 [0.60-0.84], P =0.21). In the 45 patients with no arrhythmia and receiving ventilation with tidal volume AUC ROC =0.86 [0.72-0.95] vs 0.66 [0.49-0.80], P =0.02. Δ VE E'CO2 outperformed Δ VE PP, Δ VE SBP, Δ VE MBP, Δ VE FemFlow, and Δ VE HR and, during protective ventilation, arrhythmia, or both, it also outperformed Δ VE PPV. A value of Δ VE E'CO2 >1 mm Hg (>0.13 kPa) indicated a likely response to VE. © The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  9. Complications after implantation of a new-generation insertable cardiac monitor

    DEFF Research Database (Denmark)

    Diederichsen, Søren Zöga; Haugan, Ketil Jørgen; Højberg, Søren

    2017-01-01

    BACKGROUND: Insertable cardiac monitors (ICM) are leadless devices utilized in long-term monitoring of the heart rhythm. The implantation procedure of the new-generation ICMs is minimally invasive, but little experience exists regarding complications. We thus aimed to investigate adverse events (AE...

  10. A portable cadmium telluride multidetector probe for cardiac function monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Arntz, Y.; Chambron, J.; Dumitresco, B.; Eclancher, B. E-mail: eclan@alsace.u-strasbg.fr; Prat, V

    1999-06-01

    A new nuclear stethoscope based on a matrix of small CdTe semiconductor detectors has been developed for studying the cardiac performance by gamma ventriculography at the equilibrium, in rest and stress conditions, in the early and recovery phases of the coronary disease and to follow the long-term therapy. The light-weight probe consists of an array of 64 detectors 5x5x2 mm grouped in 16 independent units in a lead shielded aluminum box including 16 preamplifiers. The probe is connected to an electronic box containing DC power supply, 16 channel amplifiers, discriminators and counters, two analog-triggering ECG channels, and interface to a PC. The left ventricle activity is, preferentially, detected by using a low-resolution matching convergent collimator. A physical evaluation of the probe has been performed, both with static tests and dynamically with a hydraulic home-built model of beating heart ventricle paced by a rhythm simulator. The sum of the 16 detectors activity provided a radiocardiogram (RCG) which well depicted the filling and ejection of the cardiac beats, allowing to compare the clinically relevant parameters of the cardiac performance, proportional variables of the stroke volume (SV), ejection fraction (EF) and ventricular flow-rate with the known absolute values programmed on the model. The portable system is now in operation for clinical assessment of cardiac patients.

  11. A portable cadmium telluride multidetector probe for cardiac function monitoring

    International Nuclear Information System (INIS)

    Arntz, Y.; Chambron, J.; Dumitresco, B.; Eclancher, B.; Prat, V.

    1999-01-01

    A new nuclear stethoscope based on a matrix of small CdTe semiconductor detectors has been developed for studying the cardiac performance by gamma ventriculography at the equilibrium, in rest and stress conditions, in the early and recovery phases of the coronary disease and to follow the long-term therapy. The light-weight probe consists of an array of 64 detectors 5x5x2 mm grouped in 16 independent units in a lead shielded aluminum box including 16 preamplifiers. The probe is connected to an electronic box containing DC power supply, 16 channel amplifiers, discriminators and counters, two analog-triggering ECG channels, and interface to a PC. The left ventricle activity is, preferentially, detected by using a low-resolution matching convergent collimator. A physical evaluation of the probe has been performed, both with static tests and dynamically with a hydraulic home-built model of beating heart ventricle paced by a rhythm simulator. The sum of the 16 detectors activity provided a radiocardiogram (RCG) which well depicted the filling and ejection of the cardiac beats, allowing to compare the clinically relevant parameters of the cardiac performance, proportional variables of the stroke volume (SV), ejection fraction (EF) and ventricular flow-rate with the known absolute values programmed on the model. The portable system is now in operation for clinical assessment of cardiac patients

  12. Comparison of an Endotracheal Cardiac Output Monitor to a Pulmonary Artery Catheter

    Science.gov (United States)

    2017-12-04

    8217-’ ’ ,, Background In combat, initial resuscitation and life saving measures are in itiated by securing a patent airway and administering fluid therapy. Wh...ile methods of fluid resuscitation remain controversial , maintenance of a patent airway and hemodynamic stabi lity as indicated by invasive...monito ri ng can influence the overall outcome of an injured individual. A patent airway may be maintained via an endotracheal tube . The use of

  13. Indexation of cardiac output to biometric parameters in critically ill patients: A systematic analysis of a transpulmonary thermodilution-derived database.

    Science.gov (United States)

    Saugel, Bernd; Mair, Sebastian; Götz, Simon Q; Tschirdewahn, Julia; Frank, Johanna; Höllthaler, Josef; Schmid, Roland M; Huber, Wolfgang

    2015-10-01

    Cardiac output (CO) (liters per minute) is usually normalized (ie, indexed) to the patient's body surface area (BSA) resulting in the hemodynamic variable cardiac index (CI) (liters per minute per square meter). We aimed (1) to evaluate the impact of different body weight-based CO indexations on the resulting CI values and (2) to identify biometric parameters independently associated with CO in critically ill patients. The study is an analysis of a database containing transpulmonary thermodilution-derived hemodynamic variables of 234 medical intensive care unit patients. Cardiac index indexed to actual BSA was statistically significantly lower compared with CI indexed to predicted BSA in the totality of patients and in the subgroups of patients with body mass index greater than or equal to 25 kg/m(2) but less than 30 kg/m(2) and body mass index greater than or equal to 30 kg/m(2) (with a statistically significant difference in the proportion of low and high CI measurements). Multivariate analysis of the first CO measurement of each patient demonstrated that CO was independently associated with age (P biometric factors independently associated with CO. Age was identified as the most important factor with each year of age decreasing CO by 66 mL/min (95% confidence interval, 47-86 mL/min). The indexation of CO to BSA is highly dependent on the body weight estimation formula used to calculate BSA. Cardiac output is independently associated with the biometric factors age, height, and BWact. These factors might be considered for indexation of CO. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Low cardiac output as physiological phenomenon in hibernating, free-ranging Scandinavian brown bears (Ursus arctos) - an observational study

    DEFF Research Database (Denmark)

    Jørgensen, Peter Godsk; Arnemo, Jon; Swenson, Jon E

    2014-01-01

    cardiac function associated with metabolic depression in the hibernating vs. active states in free-ranging Scandinavian brown bears. METHODS: We performed echocardiography on seven free-ranging brown bears in Dalarna, Sweden, anesthetized with medetomidine-zolazepam-tiletamine-ketamine during winter.......31) l/min vs. 3.54 (SD: 1.04) l/min (P=0.003), and mean cardiac index 0.63 (SD: 0.21) l/min/kg vs. 2.45 (SD: 0.52) l/min/ m2 (Pdisease...

  15. Effect of Levosimendan on Low Cardiac Output Syndrome in Patients With Low Ejection Fraction Undergoing Coronary Artery Bypass Grafting With Cardiopulmonary Bypass

    Science.gov (United States)

    Caruba, Thibaut; Grosjean, Sandrine; Amour, Julien; Ouattara, Alexandre; Villacorta, Judith; Miguet, Bertrand; Guinet, Patrick; Lévy, François; Squara, Pierre; Aït Hamou, Nora; Carillon, Aude; Boyer, Julie; Boughenou, Marie-Fazia; Rosier, Sebastien; Robin, Emmanuel; Radutoiu, Mihail; Durand, Michel; Guidon, Catherine; Desebbe, Olivier; Charles-Nelson, Anaïs; Menasché, Philippe; Rozec, Bertrand; Girard, Claude; Fellahi, Jean-Luc; Pirracchio, Romain; Chatellier, Gilles

    2017-01-01

    Importance Low cardiac output syndrome after cardiac surgery is associated with high morbidity and mortality in patients with impaired left ventricular function. Objective To assess the ability of preoperative levosimendan to prevent postoperative low cardiac output syndrome. Design, Setting, and Participants Randomized, double-blind, placebo-controlled trial conducted in 13 French cardiac surgical centers. Patients with a left ventricular ejection fraction less than or equal to 40% and scheduled for isolated or combined coronary artery bypass grafting with cardiopulmonary bypass were enrolled from June 2013 until May 2015 and followed during 6 months (last follow-up, November 30, 2015). Interventions Patients were assigned to a 24-hour infusion of levosimendan 0.1 µg/kg/min (n = 167) or placebo (n = 168) initiated after anesthetic induction. Main Outcomes and Measures Composite end point reflecting low cardiac output syndrome with need for a catecholamine infusion 48 hours after study drug initiation, need for a left ventricular mechanical assist device or failure to wean from it at 96 hours after study drug initiation when the device was inserted preoperatively, or need for renal replacement therapy at any time postoperatively. It was hypothesized that levosimendan would reduce the incidence of this composite end point by 15% in comparison with placebo. Results Among 336 randomized patients (mean age, 68 years; 16% women), 333 completed the trial. The primary end point occurred in 87 patients (52%) in the levosimendan group and 101 patients (61%) in the placebo group (absolute risk difference taking into account center effect, −7% [95% CI, −17% to 3%]; P = .15). Predefined subgroup analyses found no interaction with ejection fraction less than 30%, type of surgery, and preoperative use of β-blockers, intra-aortic balloon pump, or catecholamines. The prevalence of hypotension (57% vs 48%), atrial fibrillation (50% vs 40%), and other adverse

  16. Effect of Levosimendan on Low Cardiac Output Syndrome in Patients With Low Ejection Fraction Undergoing Coronary Artery Bypass Grafting With Cardiopulmonary Bypass: The LICORN Randomized Clinical Trial.

    Science.gov (United States)

    Cholley, Bernard; Caruba, Thibaut; Grosjean, Sandrine; Amour, Julien; Ouattara, Alexandre; Villacorta, Judith; Miguet, Bertrand; Guinet, Patrick; Lévy, François; Squara, Pierre; Aït Hamou, Nora; Carillion, Aude; Boyer, Julie; Boughenou, Marie-Fazia; Rosier, Sebastien; Robin, Emmanuel; Radutoiu, Mihail; Durand, Michel; Guidon, Catherine; Desebbe, Olivier; Charles-Nelson, Anaïs; Menasché, Philippe; Rozec, Bertrand; Girard, Claude; Fellahi, Jean-Luc; Pirracchio, Romain; Chatellier, Gilles

    2017-08-08

    Low cardiac output syndrome after cardiac surgery is associated with high morbidity and mortality in patients with impaired left ventricular function. To assess the ability of preoperative levosimendan to prevent postoperative low cardiac output syndrome. Randomized, double-blind, placebo-controlled trial conducted in 13 French cardiac surgical centers. Patients with a left ventricular ejection fraction less than or equal to 40% and scheduled for isolated or combined coronary artery bypass grafting with cardiopulmonary bypass were enrolled from June 2013 until May 2015 and followed during 6 months (last follow-up, November 30, 2015). Patients were assigned to a 24-hour infusion of levosimendan 0.1 µg/kg/min (n = 167) or placebo (n = 168) initiated after anesthetic induction. Composite end point reflecting low cardiac output syndrome with need for a catecholamine infusion 48 hours after study drug initiation, need for a left ventricular mechanical assist device or failure to wean from it at 96 hours after study drug initiation when the device was inserted preoperatively, or need for renal replacement therapy at any time postoperatively. It was hypothesized that levosimendan would reduce the incidence of this composite end point by 15% in comparison with placebo. Among 336 randomized patients (mean age, 68 years; 16% women), 333 completed the trial. The primary end point occurred in 87 patients (52%) in the levosimendan group and 101 patients (61%) in the placebo group (absolute risk difference taking into account center effect, -7% [95% CI, -17% to 3%]; P = .15). Predefined subgroup analyses found no interaction with ejection fraction less than 30%, type of surgery, and preoperative use of β-blockers, intra-aortic balloon pump, or catecholamines. The prevalence of hypotension (57% vs 48%), atrial fibrillation (50% vs 40%), and other adverse events did not significantly differ between levosimendan and placebo. Among patients with low ejection fraction

  17. Electrophysiological Monitoring of Brain Injury and Recovery after Cardiac Arrest

    Directory of Open Access Journals (Sweden)

    Ruoxian Deng

    2015-10-01

    Full Text Available Reliable prognostic methods for cerebral functional outcome of post cardiac-arrest (CA patients are necessary, especially since therapeutic hypothermia (TH as a standard treatment. Traditional neurophysiological prognostic indicators, such as clinical examination and chemical biomarkers, may result in indecisive outcome predictions and do not directly reflect neuronal activity, though they have remained the mainstay of clinical prognosis. The most recent advances in electrophysiological methods—electroencephalography (EEG pattern, evoked potential (EP and cellular electrophysiological measurement—were developed to complement these deficiencies, and will be examined in this review article. EEG pattern (reactivity and continuity provides real-time and accurate information for early-stage (particularly in the first 24 h hypoxic-ischemic (HI brain injury patients with high sensitivity. However, the signal is easily affected by external stimuli, thus the measurements of EP should be combined with EEG background to validate the predicted neurologic functional result. Cellular electrophysiology, such as multi-unit activity (MUA and local field potentials (LFP, has strong potential for improving prognostication and therapy by offering additional neurophysiologic information to understand the underlying mechanisms of therapeutic methods. Electrophysiology provides reliable and precise prognostication on both global and cellular levels secondary to cerebral injury in cardiac arrest patients treated with TH.

  18. False alarm reduction in BSN-based cardiac monitoring using signal quality and activity type information.

    Science.gov (United States)

    Tanantong, Tanatorn; Nantajeewarawat, Ekawit; Thiemjarus, Surapa

    2015-02-09

    False alarms in cardiac monitoring affect the quality of medical care, impacting on both patients and healthcare providers. In continuous cardiac monitoring using wireless Body Sensor Networks (BSNs), the quality of ECG signals can be deteriorated owing to several factors, e.g., noises, low battery power, and network transmission problems, often resulting in high false alarm rates. In addition, body movements occurring from activities of daily living (ADLs) can also create false alarms. This paper presents a two-phase framework for false arrhythmia alarm reduction in continuous cardiac monitoring, using signals from an ECG sensor and a 3D accelerometer. In the first phase, classification models constructed using machine learning algorithms are used for labeling input signals. ECG signals are labeled with heartbeat types and signal quality levels, while 3D acceleration signals are labeled with ADL types. In the second phase, a rule-based expert system is used for combining classification results in order to determine whether arrhythmia alarms should be accepted or suppressed. The proposed framework was validated on datasets acquired using BSNs and the MIT-BIH arrhythmia database. For the BSN dataset, acceleration and ECG signals were collected from 10 young and 10 elderly subjects while they were performing ADLs. The framework reduced the false alarm rate from 9.58% to 1.43% in our experimental study, showing that it can potentially assist physicians in diagnosing a vast amount of data acquired from wireless sensors and enhance the performance of continuous cardiac monitoring.

  19. False Alarm Reduction in BSN-Based Cardiac Monitoring Using Signal Quality and Activity Type Information

    Directory of Open Access Journals (Sweden)

    Tanatorn Tanantong

    2015-02-01

    Full Text Available False alarms in cardiac monitoring affect the quality of medical care, impacting on both patients and healthcare providers. In continuous cardiac monitoring using wireless Body Sensor Networks (BSNs, the quality of ECG signals can be deteriorated owing to several factors, e.g., noises, low battery power, and network transmission problems, often resulting in high false alarm rates. In addition, body movements occurring from activities of daily living (ADLs can also create false alarms. This paper presents a two-phase framework for false arrhythmia alarm reduction in continuous cardiac monitoring, using signals from an ECG sensor and a 3D accelerometer. In the first phase, classification models constructed using machine learning algorithms are used for labeling input signals. ECG signals are labeled with heartbeat types and signal quality levels, while 3D acceleration signals are labeled with ADL types. In the second phase, a rule-based expert system is used for combining classification results in order to determine whether arrhythmia alarms should be accepted or suppressed. The proposed framework was validated on datasets acquired using BSNs and the MIT-BIH arrhythmia database. For the BSN dataset, acceleration and ECG signals were collected from 10 young and 10 elderly subjects while they were performing ADLs. The framework reduced the false alarm rate from 9.58% to 1.43% in our experimental study, showing that it can potentially assist physicians in diagnosing a vast amount of data acquired from wireless sensors and enhance the performance of continuous cardiac monitoring.

  20. The Evolution and Application of Cardiac Monitoring for Occult Atrial Fibrillation in Cryptogenic Stroke and TIA.

    Science.gov (United States)

    Miller, Daniel J; Shah, Kavit; Modi, Sumul; Mahajan, Abhimanyu; Zahoor, Salman; Affan, Muhammad

    2016-04-01

    The evaluation of the stroke and transient ischemic attack (TIA) patient has been historically predominated by the initial evaluation in the hospital setting. As the etiology of stroke has eluded us in approximately one third of all acute events, the medical community has been eager to seek the answer to this mystery. In recent years, we have seen an explosion of innovations and trends allowing for a more detailed post stroke assessment strategy aimed at the identification of occult atrial fibrillation as the etiologic cause for the cryptogenic event. This has been achieved through the evolution and aggressive application and study of prolonged and advanced cardiac monitoring. This review is aimed to clarify and elucidate the standard and novel cardiac monitoring methods that have become available for use by the medical community and expected in the higher level care of cryptogenic stroke and TIA patients. These cardiac monitoring methods and devices are as heterogeneous as our patient population and have their own advantages and disadvantages. Many factors may be taken into consideration in choosing the appropriate cardiac monitoring method and are highlighted for consideration in this review. With a judicious approach to investigating the cryptogenic stroke population, and applying a wealth of novel treatment options, we may move forward into a new era of stroke prevention.

  1. Engineered hybrid cardiac patches with multifunctional electronics for online monitoring and regulation of tissue function.

    Science.gov (United States)

    Feiner, Ron; Engel, Leeya; Fleischer, Sharon; Malki, Maayan; Gal, Idan; Shapira, Assaf; Shacham-Diamand, Yosi; Dvir, Tal

    2016-06-01

    In cardiac tissue engineering approaches to treat myocardial infarction, cardiac cells are seeded within three-dimensional porous scaffolds to create functional cardiac patches. However, current cardiac patches do not allow for online monitoring and reporting of engineered-tissue performance, and do not interfere to deliver signals for patch activation or to enable its integration with the host. Here, we report an engineered cardiac patch that integrates cardiac cells with flexible, freestanding electronics and a 3D nanocomposite scaffold. The patch exhibited robust electronic properties, enabling the recording of cellular electrical activities and the on-demand provision of electrical stimulation for synchronizing cell contraction. We also show that electroactive polymers containing biological factors can be deposited on designated electrodes to release drugs in the patch microenvironment on demand. We expect that the integration of complex electronics within cardiac patches will eventually provide therapeutic control and regulation of cardiac function.

  2. Validation of maternal cardiac output assessed by transthoracic echocardiography against pulmonary artery catheterization in severely ill pregnant women: prospective comparative study and systematic review.

    Science.gov (United States)

    Cornette, J; Laker, S; Jeffery, B; Lombaard, H; Alberts, A; Rizopoulos, D; Roos-Hesselink, J W; Pattinson, R C

    2017-01-01

    Most severe pregnancy complications are characterized by profound hemodynamic disturbances, thus there is a need for validated hemodynamic monitoring systems for pregnant women. Pulmonary artery catheterization (PAC) using thermodilution is the clinical gold standard for the measurement of cardiac output (CO), however this reference method is rarely performed owing to its invasive nature. Transthoracic echocardiography (TTE) allows non-invasive determination of CO. We aimed to validate TTE against PAC for the determination of CO in severely ill pregnant women. This study consisted of a meta-analysis combining data from a prospective study and a systematic review. The prospective arm was conducted in Pretoria, South Africa, in 2003. Women with severe pregnancy complications requiring invasive monitoring with PAC according to contemporary guidelines were included. TTE was performed within 15 min of PAC and the investigator was blinded to the PAC measurements. Comparative measurements were extracted from similar studies retrieved from a systematic review of the literature and added to a database. Simultaneous CO measurements by TTE and PAC were compared. Agreement between methods was assessed using Bland-Altman statistics and intraclass correlation coefficients (ICC). Thirty-four comparative measurements were included in the meta-analysis. Mean CO values obtained by PAC and TTE were 7.39 L/min and 7.18 L/min, respectively. The bias was 0.21 L/min with lower and upper limits of agreement of -1.18 L/min and 1.60 L/min, percentage error was 19.1%, and ICC between the two methods was 0.94. CO measurements by TTE show excellent agreement with those obtained by PAC in pregnant women. Given its non-invasive nature and availability, TTE could be considered as a reference for the validation of other CO techniques in pregnant women. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Las complicaciones del embarazo más graves se caracterizan por trastornos hemodin

  3. A portable cadmium telluride multidetector probe for cardiac function monitoring

    CERN Document Server

    Arntz, Y; Dumitresco, B; Eclancher, B; Prat, V

    1999-01-01

    A new nuclear stethoscope based on a matrix of small CdTe semiconductor detectors has been developed for studying the cardiac performance by gamma ventriculography at the equilibrium, in rest and stress conditions, in the early and recovery phases of the coronary disease and to follow the long-term therapy. The light-weight probe consists of an array of 64 detectors 5x5x2 mm grouped in 16 independent units in a lead shielded aluminum box including 16 preamplifiers. The probe is connected to an electronic box containing DC power supply, 16 channel amplifiers, discriminators and counters, two analog-triggering ECG channels, and interface to a PC. The left ventricle activity is, preferentially, detected by using a low-resolution matching convergent collimator. A physical evaluation of the probe has been performed, both with static tests and dynamically with a hydraulic home-built model of beating heart ventricle paced by a rhythm simulator. The sum of the 16 detectors activity provided a radiocardiogram (RCG) wh...

  4. Monitoring of cardiac antirejection therapy with 111In lymphocytes

    International Nuclear Information System (INIS)

    Lerch, R.A.; Bergmann, S.R.; Carlson, E.M.; Saffitz, J.E.; Sobel, B.E.

    1982-01-01

    To determine whether lymphocytes labeled with 111 In permit noninvasive assessment of antirejection therapy, we performed 40 allogeneic heterotopic cardiac transplants in rats. Antirejection therapy with azathioprine (30 mg/kg) and sodium salicylate (200 mg/kg) prolonged contractile function of the graft from 7.5 +/- 1.5 (s.d.) days in controls to 19.4 +/- 3.7 days in treated animals. Six to seven days after transplantation, autologous lymphocytes labeled with 111 In were injected intravenously in seven untreated and eight treated rats. Scintigraphy and organ counting were performed 24 hr after administration of labeled cells. At sacrifice all grafts in untreated rats exhibited contractile failure, whereas grafts in all treated rats were beating well. Transplants in untreated recipients exhibited marked accumulation of 111 In lymphocytes detectable scintigraphically, with ratios of 7.7 +/- 1.9 for the activity in the transplant over that in the native heart (HT/HO), as obtained by well counting. In contrast, accumulation was not scintigraphically detectable in transplants of treated rats, with HT/HO ratios of 2.6 +/- 1.8 (p less than 0.005). The results suggested that imaging with 111 In-labeled lymphocytes will permit noninvasive assessment of antirejection therapy

  5. Remote monitoring of implantable cardiac devices: current state and future directions.

    Science.gov (United States)

    Ganeshan, Raj; Enriquez, Alan D; Freeman, James V

    2018-01-01

    Recent evidence has demonstrated substantial benefits associated with remote monitoring of cardiac implantable electronic devices (CIEDs), and treatment guidelines have endorsed the use of remote monitoring. Familiarity with the features of remote monitoring systems and the data supporting its use are vital for physicians' care for patients with CEIDs. Remote monitoring remains underutilized, but its use is expanding including in new practice settings including emergency departments. Patient experience and outcomes are positive, with earlier detection of clinical events such as atrial fibrillation, reductions in inappropriate implantable cardioverter-defibrillator (ICD) shocks and potentially a decrease in mortality with frequent remote monitoring utilizaiton. Rates of hospitalization are reduced among remote monitoring users, and the replacement of outpatient follow-up visits with remote monitoring transmissions has been shown to be well tolerated. In addition, health resource utilization is lower and remote monitoring has been associated with considerable cost savings. A dose relationship exists between use of remote monitoring and patient outcomes, and those with early and high transmission rates have superior outcomes. Remote monitoring provides clinicians with the ability to provide comprehensive follow-up care for patients with CIEDs. Patient outcomes are improved, and resource utilization is decreased with appropriate use of remote monitoring. Future efforts must focus on improving the utilization and efficiency of remote monitoring.

  6. Prophylactic levosimendan for the prevention of low cardiac output syndrome and mortality in paediatric patients undergoing surgery for congenital heart disease.

    Science.gov (United States)

    Hummel, Johanna; Rücker, Gerta; Stiller, Brigitte

    2017-08-02

    Low cardiac output syndrome remains a serious complication, and accounts for substantial morbidity and mortality in the postoperative course of paediatric patients undergoing surgery for congenital heart disease. Standard prophylactic and therapeutic strategies for low cardiac output syndrome are based mainly on catecholamines, which are effective drugs, but have considerable side effects. Levosimendan, a calcium sensitiser, enhances the myocardial function by generating more energy-efficient myocardial contractility than achieved via adrenergic stimulation with catecholamines. Thus potentially, levosimendan is a beneficial alternative to standard medication for the prevention of low cardiac output syndrome in paediatric patients after open heart surgery. To review the efficacy and safety of the postoperative prophylactic use of levosimendan for the prevention of low cardiac output syndrome and mortality in paediatric patients undergoing surgery for congenital heart disease. We identified trials via systematic searches of CENTRAL, MEDLINE, Embase, and Web of Science, as well as clinical trial registries, in June 2016. Reference lists from primary studies and review articles were checked for additional references. We only included randomised controlled trials (RCT) in our analysis that compared prophylactic levosimendan with standard medication or placebo, in infants and children up to 18 years of age, who were undergoing surgery for congenital heart disease. Two review authors independently extracted data and assessed risk of bias according to a pre-defined protocol. We obtained additional information from all but one of the study authors of the included studies. We used the five GRADE considerations (study limitations, consistency of effect, imprecision, indirectness, and publication bias) to assess the quality of evidence from the studies that contributed data to the meta-analyses for the prespecified outcomes. We created a 'Summary of findings' table to

  7. System for the diagnosis and monitoring of coronary artery disease, acute coronary syndromes, cardiomyopathy and other cardiac conditions

    Science.gov (United States)

    Schlegel, Todd T. (Inventor); Arenare, Brian (Inventor)

    2008-01-01

    Cardiac electrical data are received from a patient, manipulated to determine various useful aspects of the ECG signal, and displayed and stored in a useful form using a computer. The computer monitor displays various useful information, and in particular graphically displays various permutations of reduced amplitude zones and kurtosis that increase the rapidity and accuracy of cardiac diagnoses. New criteria for reduced amplitude zones are defined that enhance the sensitivity and specificity for detecting cardiac abnormalities.

  8. Cardiodynamicsgram: a novel tool for monitoring cardiac function in exercise training.

    Science.gov (United States)

    Wen, Xu; Guo, Bokai; Gong, Yinglan; Xia, Ling; Yu, Jie

    2018-04-27

    This study evaluated the feasibility of cardiodynamicsgram (CDG) for monitoring the cardiac functions of athletes and exercisers. CDG could provide an effective, simple, and economical tool for exercise training. Seventeen middle-distance race athletes aged 14-28 years old were recruited. CDG tests and blood test including creatine kinase (CK), CK-MB isoenzyme, and high-sensitivity troponin I (hsTnI) were performed before a high-intensity prolonged training, as well as 2 and 14 h after training, respectively. The CDG test result was unsatisfactory when the CK test result was used as standard. However, the accuracy of CDG test was about 80% when CK-MB and hsTnI were used as standards. Thus, CDG offers a noninvasive, simple, and economical approach for monitoring the cardiac function of athletes and exercisers during exercise training. Nonetheless, the applicability of CDG needs further investigation.

  9. A NOVEL BCG SENSOR-ARRAY FOR UNOBTRUSIVE CARDIAC MONITORING

    Directory of Open Access Journals (Sweden)

    Anna Böhm

    2013-12-01

    Full Text Available Unobtrusive heart rate monitoring is a popular research topic in biomedical engineering. The reason is that convential methods, e.g. the clinical gold standard electrocardiography, require conductive contact to the human body. Other methods such as ballistocardiography try to record these vital signs without electrodes that are attached to the body. So far, these systems cannot replace routine procedures. Most systems have some drawbacks that cannot be compensated, such as aging of the sensor materials or movement artifacts. In addition, the signal form differs greatly from an ECG, which is an electrical signal. The ballistocardiogram has a mechanical source, which makes it harder to evaluate. We have developed a new sensor array made of near-IR-LEDs to record BCGs. IR-sensors do not age in relevant time scales. Analog filtering was neccesary, because the signal amplitude was very small. The digitized data was then processed by various algorithms to extract beat-to-beat or breath-to-breath intervals. The redundancy of multiple BCG channels was used to provide a robust estimation of beat-to-beat intervals and heart rate. We installed the system beneath a mattress topper of a hospital bed, but any other bed would have been sufficient. The validation of this measurement system shows that it is well suited for BCG recordings. The use of multiple channels has proven to be superior to relying on a single BCG channel.

  10. Feasibility of Stereo-Infrared Tracking to Monitor Patient Motion During Cardiac SPECT Imaging

    OpenAIRE

    Beach, Richard D.; Pretorius, P. Hendrik; Boening, Guido; Bruyant, Philippe P.; Feng, Bing; Fulton, Roger R.; Gennert, Michael A.; Nadella, Suman; King, Michael A.

    2004-01-01

    Patient motion during cardiac SPECT imaging can cause diagnostic imaging artifacts. We investigated the feasibility of monitoring patient motion using the Polaris motion-tracking system. This system uses passive infrared reflection from small spheres to provide real-time position data with vendor stated 0.35 mm accuracy and 0.2 mm repeatability. In our configuration, the Polaris system views through the SPECT gantry toward the patient's head. List-mode event data was temporally synchronized w...

  11. Uncomplicated human type 2 diabetes is associated with meal-induced blood pressure lowering and cardiac output increase.

    Science.gov (United States)

    Smits, Mark M; Muskiet, Marcel H A; Tushuizen, Maarten E; Kwa, Kelly A A; Karemaker, John M; van Raalte, Daniël H; Diamant, Michaela

    2014-12-01

    Since many type 2 diabetes patients experience postprandial hypotension, the aim of this study was to unravel meal-related changes in systemic hemodynamics and autonomic nervous system (ANS)-balance. Forty-two age-matched males (15 type 2 diabetes; 12 metabolic syndrome; 15 controls) without overt autonomic neuropathy received a standardized high-fat mixed meal after an overnight fast. Hemodynamic variables were measured by finger plethysmography. Fourier analysis was used to calculate the low-/high-frequency (LF/HF)-ratio, a marker of autonomic nervous system-balance, and baroreceptor reflex sensitivity (BRS). Following the meal, diastolic blood pressure (DBP) decreased in type 2 diabetes patients only, paralleled by a significant decrement in systemic vascular resistance (SVR) and an increase in cardiac index. All groups showed an increase in postprandial heart rate. Controls, but not metabolic syndrome or type 2 diabetes patients, showed a meal-related increase in LF/HF-ratio. When combining all study subjects, homeostatic model assessment-insulin resistance (HOMA-IR) was inversely correlated with changes in DBP, SVR, LF/HF-ratio and BRS. Based on these data, we hypothesize that in patients with uncomplicated type 2 diabetes, insulin resistance hampers adequate meal-induced sympathetic activation, leading to a decrease in SVR and resulting in a postprandial drop in DBP. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  12. Diagnostic Yield of Extended Cardiac Patch Monitoring in Patients with Stroke or TIA

    Directory of Open Access Journals (Sweden)

    Christie E Tung

    2015-01-01

    Full Text Available Background: It is important to evaluate patients with TIA or stroke for atrial fibrillation (AF because the detection of AF changes the recommended anti-thrombotic regimen from treatment with an antiplatelet agent to oral anticoagulation. This study describes the diagnostic yield of a patch-based, single-use, and water-resistant 14-day continuous cardiac rhythm monitor (ZIO Patch in patients with stroke or TIA.Methods: We obtained data from the manufacturer and servicer of the ZIO Patch (iRhythm Technologies. Patients who were monitored between January 2012 and June 2013 and whose indication for monitoring was TIA or stroke were included. The duration of monitoring, the number and type of arrhythmias, and the time to first arrhythmia were documented. Results: 1,171 monitoring reports were analyzed. The mean monitor wear time was 10.9 days and the median wear time was 13.0 days (interquartile range 7.2-14.0. The median analyzable time relative to the total wear time was 98.7% (IQR 96.0-99.5%. AF was present in 5.0% of all reports. The mean duration before the first episode of paroxysmal AF (PAF was 1.5 days and the median duration was 0.4 days. 14.3% of first PAF episodes occurred after 48 hours. The mean PAF burden was 12.7% of the total monitoring duration. Conclusion: Excellent quality of the recordings and very good patient compliance coupled with a substantial proportion of AF detection beyond the first 48 hours of monitoring suggest that the cardiac patch is superior to conventional 48-hour Holter monitors for AF detection in patients with stroke or TIA.

  13. Diagnostic Yield of Extended Cardiac Patch Monitoring in Patients with Stroke or TIA.

    Science.gov (United States)

    Tung, Christie E; Su, Derek; Turakhia, Mintu P; Lansberg, Maarten G

    2014-01-01

    It is important to evaluate patients with transient ischemic attack (TIA) or stroke for atrial fibrillation (AF) because the detection of AF changes the recommended anti-thrombotic regimen from treatment with an antiplatelet agent to oral anticoagulation. This study describes the diagnostic yield of a patch-based, single-use, and water-resistant 14-day continuous cardiac rhythm monitor (ZIO Patch) in patients with stroke or TIA. We obtained data from the manufacturer and servicer of the ZIO Patch (iRhythm Technologies). Patients who were monitored between January 2012 and June 2013 and whose indication for monitoring was TIA or stroke were included. The duration of monitoring, the number and type of arrhythmias, and the time to first arrhythmia were documented. One thousand one hundred seventy-one monitoring reports were analyzed. The mean monitor wear time was 10.9 days and the median wear time was 13.0 days (interquartile range 7.2-14.0). The median analyzable time relative to the total wear time was 98.7% (IQR 96.0-99.5%). AF was present in 5.0% of all reports. The mean duration before the first episode of paroxysmal AF (PAF) was 1.5 days and the median duration was 0.4 days. 14.3% of first PAF episodes occurred after 48 h. The mean PAF burden was 12.7% of the total monitoring duration. Excellent quality of the recordings and very good patient compliance coupled with a substantial proportion of AF detection beyond the first 48 h of monitoring suggest that the cardiac patch is superior to conventional 48-h Holter monitors for AF detection in patients with stroke or TIA.

  14. On the Design of an Efficient Cardiac Health Monitoring System Through Combined Analysis of ECG and SCG Signals.

    Science.gov (United States)

    Sahoo, Prasan Kumar; Thakkar, Hiren Kumar; Lin, Wen-Yen; Chang, Po-Cheng; Lee, Ming-Yih

    2018-01-28

    Cardiovascular disease (CVD) is a major public concern and socioeconomic problem across the globe. The popular high-end cardiac health monitoring systems such as magnetic resonance imaging (MRI), computerized tomography scan (CT scan), and echocardiography (Echo) are highly expensive and do not support long-term continuous monitoring of patients without disrupting their activities of daily living (ADL). In this paper, the continuous and non-invasive cardiac health monitoring using unobtrusive sensors is explored aiming to provide a feasible and low-cost alternative to foresee possible cardiac anomalies in an early stage. It is learned that cardiac health monitoring based on sole usage of electrocardiogram (ECG) signals may not provide powerful insights as ECG provides shallow information on various cardiac activities in the form of electrical impulses only. Hence, a novel low-cost, non-invasive seismocardiogram (SCG) signal along with ECG signals are jointly investigated for the robust cardiac health monitoring. For this purpose, the in-laboratory data collection model is designed for simultaneous acquisition of ECG and SCG signals followed by mechanisms for the automatic delineation of relevant feature points in acquired ECG and SCG signals. In addition, separate feature points based novel approach is adopted to distinguish between normal and abnormal morphology in each ECG and SCG cardiac cycle. Finally, a combined analysis of ECG and SCG is carried out by designing a Naïve Bayes conditional probability model. Experiments on Institutional Review Board (IRB) approved licensed ECG/SCG signals acquired from real subjects containing 12,000 cardiac cycles show that the proposed feature point delineation mechanisms and abnormal morphology detection methods consistently perform well and give promising results. In addition, experimental results show that the combined analysis of ECG and SCG signals provide more reliable cardiac health monitoring compared to the

  15. On the Design of an Efficient Cardiac Health Monitoring System Through Combined Analysis of ECG and SCG Signals

    Directory of Open Access Journals (Sweden)

    Prasan Kumar Sahoo

    2018-01-01

    Full Text Available Cardiovascular disease (CVD is a major public concern and socioeconomic problem across the globe. The popular high-end cardiac health monitoring systems such as magnetic resonance imaging (MRI, computerized tomography scan (CT scan, and echocardiography (Echo are highly expensive and do not support long-term continuous monitoring of patients without disrupting their activities of daily living (ADL. In this paper, the continuous and non-invasive cardiac health monitoring using unobtrusive sensors is explored aiming to provide a feasible and low-cost alternative to foresee possible cardiac anomalies in an early stage. It is learned that cardiac health monitoring based on sole usage of electrocardiogram (ECG signals may not provide powerful insights as ECG provides shallow information on various cardiac activities in the form of electrical impulses only. Hence, a novel low-cost, non-invasive seismocardiogram (SCG signal along with ECG signals are jointly investigated for the robust cardiac health monitoring. For this purpose, the in-laboratory data collection model is designed for simultaneous acquisition of ECG and SCG signals followed by mechanisms for the automatic delineation of relevant feature points in acquired ECG and SCG signals. In addition, separate feature points based novel approach is adopted to distinguish between normal and abnormal morphology in each ECG and SCG cardiac cycle. Finally, a combined analysis of ECG and SCG is carried out by designing a Naïve Bayes conditional probability model. Experiments on Institutional Review Board (IRB approved licensed ECG/SCG signals acquired from real subjects containing 12,000 cardiac cycles show that the proposed feature point delineation mechanisms and abnormal morphology detection methods consistently perform well and give promising results. In addition, experimental results show that the combined analysis of ECG and SCG signals provide more reliable cardiac health monitoring compared to

  16. Urine Biochemistry in the Early Postoperative Period after Cardiac Surgery: Role in Acute Kidney Injury Monitoring

    Directory of Open Access Journals (Sweden)

    Alexandre Toledo Maciel

    2013-01-01

    Full Text Available We have recently suggested that sequential urine electrolyte measurement in critically ill patients may be useful in monitoring kidney function. Cardiac surgery is one of the leading causes of acute kidney injury (AKI in the intensive care unit (ICU. In this paper, we describe the sequential behavior of urine electrolytes in three patients in the early (first 60 hours postoperative period after cardiac surgery according to AKI status: no AKI, transient AKI, and persistent AKI. We have found that the patient with no AKI had stable and high concentrations of sodium (NaU and chloride (ClU in sequential spot samples of urine. AKI development was characterized in the other two patients by decreases in NaU and ClU, which have started early after ICU admission. Transient AKI was marked by also transient and less severe decreases in NaU and ClU. Persistent AKI was marked by the less favorable clinical course with abrupt and prolonged declines in NaU and ClU values. These electrolytes in urine had a behavior like a “mirror image” in comparison with that of serum creatinine. We suggest that sequential urine electrolytes are useful in monitoring acute kidney injury development in the early postoperative period after cardiac surgery.

  17. Therapeutic drug monitoring of digoxin in cardiac heart failure outpatients: comparisons of two analytical methods

    Directory of Open Access Journals (Sweden)

    Isabel Cristina Medeiros Barros

    2014-01-01

    Full Text Available Objective: To compare two analytical techniques used in the determination of plasma digoxin (LC-MS/MS and immunoassay and to verify which one better answer the need of the clinical monitoring routine of patients with cardiac heart failure. Method: The clinical findings in 15 cardiac heart failure (CHF outpatients of the Cardiac Heart Service of the Goias Federal University Clinical Hospital were investigated. Blood samples of the patients were collected and analysed by Immunoassay and by Liquid Chromatography coupled to Mass Spectrometry (LC-MS/MS. Results: The results of the statistic test (Student p = 0,05 showed a significant difference between the analytical methods: immunoassay concentrations were higher than the concentrations determined by LCMS/ MS. The explanation may be because immunoassay method measures digoxin plus other metabolites and endogenous substances, while the LC-MS/MS method measures only the digoxin molecule. None of the patients, showed relevant clinical data suggestive of digitalis intoxication, even several drugs with potential interaction were associated with treatment. Conclusion: It was concluded, therefore, that LC-MS/MS me thod is safer, more selective and specific than immunoassay, being an option for therapeutic drug monitoring of digoxin, since the reference values would be obtain for digoxinemia by LC-MS/MS.

  18. Cerebral oxygenation monitoring in patients with bilateral carotid stenosis undergoing urgent cardiac surgery: Observational case series

    Directory of Open Access Journals (Sweden)

    Dincer Aktuerk

    2016-01-01

    Full Text Available Background: Patients with significant bilateral carotid artery stenosis requiring urgent cardiac surgery have an increased risk of stroke and death. The optimal management strategy remains inconclusive, and the available evidence does not support the superiority of one strategy over another. Materials and Methods: A number of noninvasive strategies have been developed for minimizing perioperative stroke including continuous real-time monitoring of cerebral oxygenation with near-infrared spectroscopy (NIRS. The number of patients presenting with this combination (bilateral significant carotid stenosis requiring urgent cardiac surgery in any single institution will be small and hence there is a lack of large randomized studies. Results: This case series describes our early experience with NIRS in a select group of patients with significant bilateral carotid stenosis undergoing urgent cardiac surgery (n = 8. In contrast to other studies, this series is a single surgeon, single center study, where the entire surgery (both distal ends and proximal ends was performed during single aortic clamp technique, which effectively removes several confounding variables. NIRS monitoring led to the early recognition of decreased cerebral oxygenation, and corrective steps (increased cardiopulmonary bypass flow, increased pCO 2 , etc., were taken. Conclusion: The study shows good clinical outcome with the use of NIRS. This is our "work in progress," and we aim to conduct a larger study.

  19. Design of a cardiac monitor in terms of parameters of QRS complex.

    Science.gov (United States)

    Chen, Zhen-cheng; Ni, Li-li; Su, Ke-ping; Wang, Hong-yan; Jiang, Da-zong

    2002-08-01

    Objective. To design a portable cardiac monitor system based on the available ordinary ECG machine and works on the basis of QRS parameters. Method. The 80196 single chip microcomputer was used as the central microprocessor and real time electrocardiac signal was collected and analyzed [correction of analysized] in the system. Result. Apart from the performance of an ordinary monitor, this machine possesses also the following functions: arrhythmia analysis, HRV analysis, alarm, freeze, and record of automatic papering. Convenient in carrying, the system is powered by AC or DC sources. Stability, low power and low cost are emphasized in the hardware design; and modularization method is applied in software design. Conclusion. Popular in usage and low cost made the portable monitor system suitable for use under simple conditions.

  20. Comparison of cardiac output optimization with an automated closed-loop goal-directed fluid therapy versus non standardized manual fluid administration during elective abdominal surgery: first prospective randomized controlled trial.

    Science.gov (United States)

    Lilot, Marc; Bellon, Amandine; Gueugnon, Marine; Laplace, Marie-Christine; Baffeleuf, Bruno; Hacquard, Pauline; Barthomeuf, Felicie; Parent, Camille; Tran, Thomas; Soubirou, Jean-Luc; Robinson, Philip; Bouvet, Lionel; Vassal, Olivia; Lehot, Jean-Jacques; Piriou, Vincent

    2018-01-27

    An intraoperative automated closed-loop system for goal-directed fluid therapy has been successfully tested in silico, in vivo and in a clinical case-control matching. This trial compared intraoperative cardiac output (CO) in patients managed with this closed-loop system versus usual practice in an academic medical center. The closed-loop system was connected to a CO monitoring system and delivered automated colloid fluid boluses. Moderate to high-risk abdominal surgical patients were randomized either to the closed-loop or the manual group. Intraoperative final CO was the primary endpoint. Secondary endpoints were intraoperative overall mean cardiac index (CI), increase from initial to final CI, intraoperative fluid volume and postoperative outcomes. From January 2014 to November 2015, 46 patients were randomized. There was a lower initial CI (2.06 vs. 2.51 l min -1 m -2 , p = 0.042) in the closed-loop compared to the control group. No difference in final CO and in overall mean intraoperative CI was observed between groups. A significant relative increase from initial to final CI values was observed in the closed-loop but not the control group (+ 28.6%, p = 0.006 vs. + 1.2%, p = 0.843). No difference was found for intraoperative fluid management and postoperative outcomes between groups. There was no significant impact on the primary study endpoint, but this was found in a context of unexpected lower initial CI in the closed-loop group.Trial registry number ID-RCB/EudraCT: 2013-A00770-45. ClinicalTrials.gov Identifier NCT01950845, date of registration: 17 September 2013.

  1. Direct recording of cardiac output- and venous return-curves in the dog heart-lung preparation for a graphical analysis of the effects of cardioactive drugs.

    Science.gov (United States)

    Ishikawa, N; Taki, K; Hojo, Y; Hagino, Y; Shigei, T

    1978-09-01

    The dog heart-lung preparations were prepared. The "equilibrium point", which could be defined as the point at which the cardiac output (CO)-curve and the venous return (VR)-curve crossed, when the CO and VR were plotted against the right atrial pressure, was recorded directly by utilizing an X-Y recorder. The CO-curve was obtained, as a locus of the equilibrium point, by raising and lowering the level of blood in the venous reservoir (competence test). The meaning of the procedure was shown to increase or decrease the mean systemic pressure, and to cause the corresponding parallel shift in the VR-curve. The VR-curve was obtained by changing myocardial contractility. When heart failure was induced by pentobarbital or by chloroform, the equilibrium point shifted downwards to the right, depicting the VR-curve. During development of the failure, the slopes of CO-curves decreased gradually. Effects of cinobufagin and norepinephrine were also analyzed. Utilization of the X-Y recorder enabled us to settle the uniform experimental conditions more easily, and to follow the effects of drugs continuously on a diagram equating the CO- and VR-curves (Gyton's scheme).

  2. G16R single nucleotide polymorphism but not haplotypes of the ß2-adrenergic receptor gene alters cardiac output in humans

    DEFF Research Database (Denmark)

    Rokamp, Kim Z; Staalsø, Jonatan M; Gartmann, Martin

    2013-01-01

    Variation in genes encoding the ß2-adrenergic receptor (ADRB2) and angiotensin-converting enzyme (ACE) may influence Q¿ (cardiac output). The 46G>A (G16R) SNP (single nucleotide polymorphism) has been associated with ß2-mediated vasodilation, but the effect of ADRB2 haplotypes on Q¿ has not been...... studied. Five SNPs within ADRB2 (46G>A, 79C>G, 491C>T, 523C>A and 1053G>C by a pairwise tagging principle) and the I/D (insertion/deletion) polymorphism in ACE were genotyped in 143 subjects. Cardiovascular variables were evaluated by the Model flow method at rest and during incremental cycling exercise...... V¿O2 (oxygen uptake) in G16G subjects, but the increase was 0.5 (0.0-0.9) l/min lower in Arg16 carriers (P=0.035). A similar effect size was observed for the Arg16 haplotypes ACCCG and ACCCC. No interaction was found between ADRB2 and ACE polymorphisms. During exercise, the increase in Q¿ was 0...

  3. Incidence of major vascular events after cardiac surgery: impact of preoperative monitoring with troponin and electrocardiogram

    International Nuclear Information System (INIS)

    Sandra M Quiroga; Juan C Villar; Luz X, Martinez

    2009-01-01

    Recent demographic changes have led to an increased risk of major vascular events among patients undergoing non-cardiac surgery. Troponin and electrocardiogram monitoring would further identify these major vascular events. Methods: we prospectively collected data on eligible patients (non-selected individuals aged 45 or older undergoing non-cardiac surgery under general or regional anesthesia in two hospitals in Bucaramanga, with expected length of stay longer than 24 hours) during a time-interrupted series,before and after postoperative diagnostic monitoring (blinded assessment of troponin T and electrocardiograms ignoring clinical data). For the period before the intervention (usual clinical care),two independent reviewers extracted clinical information from clinical histories (of all eligible patients from 3 randomly-selected months of 2005). For the period after diagnostic monitoring, we followed 100 consecutive eligible patients. Primary outcome was a composite of major vascular events within hospital, including myocardial infarction (defined as any troponin elevation associated with electrocardiographic changes suggesting ischemia, regardless of symptoms). Results: we included 534 clinical charts and 100 prospective surgical patients (mean age 62.2, SD 12.9 years; 56% women). The more frequent surgical procedures were orthopedics (26.8%) followed by abdominal (20.2%).The incidence of major vascular events recorded in clinical charts was 2.8%, compared with 7% among monitored patients (p=0,071). All four myocardial infarctions identified among the later group were silent. Conclusion: postoperative monitoring with troponin and electrocardiography identified a higher proportion of major vascular events, mainly silent myocardial infarctions.

  4. Phosphodiesterase inhibitor KMUP-3 displays cardioprotection via protein kinase G and increases cardiac output via G-protein-coupled receptor agonist activity and Ca2+ sensitization

    Directory of Open Access Journals (Sweden)

    Chung-Pin Liu

    2016-02-01

    Full Text Available KMUP-3 (7-{2-[4-(4-nitrobenzene piperazinyl]ethyl}-1, 3-dimethylxanthine displays cardioprotection and increases cardiac output, and is suggested to increase cardiac performance and improve myocardial infarction. To determine whether KMUP-3 improves outcomes in hypoperfused myocardium by inducing Ca2+ sensitization to oppose protein kinase (PKG-mediated Ca2+ blockade, we measured left ventricular systolic blood pressure, maximal rates of pressure development, mean arterial pressure and heart rate in rats, and measured contractility and expression of PKs/RhoA/Rho kinase (ROCKII in beating guinea pig left atria. Hemodynamic changes induced by KMUP-3 (0.5–3.0 mg/kg, intravenously were inhibited by Y27632 [(R-(+-trans-4-1-aminoethyl-N-(4-Pyridyl cyclohexane carboxamide] and ketanserin (1 mg/kg, intravenously. In electrically stimulated left guinea pig atria, positive inotropy induced by KMUP-3 (0.1–100μM was inhibited by the endothelial NO synthase (eNOS inhibitors N-nitro-l-arginine methyl ester (L-NAME and 7-nitroindazole, cyclic AMP antagonist SQ22536 [9-(terahydro-2-furanyl-9H-purin-6-amine], soluble guanylyl cyclase (sGC antagonist ODQ (1H-[1,2,4] oxadiazolo[4,3-a] quinoxalin-1-one, RhoA inhibitor C3 exoenzyme, β-blocker propranolol, 5-hydroxytryptamine 2A antagonist ketanserin, ROCK inhibitor Y27632 and KMUP-1 (7-{2-[4-(2-chlorobenzene piperazinyl]ethyl}-1, 3-dimethylxanthine at 10μM. Western blotting assays indicated that KMUP-3 (0.1–10μM increased PKA, RhoA/ROCKII, and PKC translocation and CIP-17 (an endogenous 17-kDa inhibitory protein activation. In spontaneous right atria, KMUP-3 induced negative chronotropy that was blunted by 7-nitroindazole and atropine. In neonatal myocytes, L-NAME inhibited KMUP-3-induced eNOS phosphorylation and RhoA/ROCK activation. In H9c2 cells, Y-27632 (50μM and PKG antagonist KT5823 [2,3,9,10,11,12-hexahydro-10R- methoxy-2,9-dimethyl-1-oxo-9S,12R-epoxy-1H-diindolo(1,2,3-fg:3′,2′,1

  5. Clinical experience in extended cardiac monitoring with the SEEQ™ satellite wireless system

    Directory of Open Access Journals (Sweden)

    Diego Vanegas-Cadavid

    2018-05-01

    Full Text Available Objectives: To present the clinical experience with a new extended (for 15 days, wireless, and satellite cardiac monitoring system in a group of patients with suspicion of cardiac arrhythmia. Method: The study included a cohort of 100 patients seen in the Cardiovascular Electrophysiology Unit of a reference hospital. They were suspected of having a cardiac arrhythmia, with no electrocardiographic diagnosis of the cause, despite previous examinations. They were subjected to SEEQ-type (Medtronic external cardiac monitoring for 15 days, with the outcomes recorded. Results: Of the total of 100 subjects studied, 51% were male, and the median age was 60 years (range: 5 - 91 years. The main symptoms were palpitation, and the most prevalent comorbidity was arterial hypertension (47%. Almost all (98% of them had a previous Holter study, and 46% had two studies, which were inconclusive in explaining the symptoms. The SEEQ monitoring recorded a significant electrocardiographic abnormality in 22% of the patients. A pacemaker implant was the treatment most applied and atrial fibrillation was the most frequent arrhythmia in 50% of the positive findings. There was a higher and significant percentage of positive diagnoses in males. Conclusions: External, satellite, wireless cardiac monitoring extended for 15 days, is a novel tool that can increase the probability of documenting a clinically significant electrocardiographic abnormality in those patients who suffer recurrent cardiovascular symptoms. Resumen: Objetivos: Dar a conocer la experiencia clínica con un nuevo sistema de monitorización cardiaca extendida (por 15 días, inalámbrica y satelital en un grupo de pacientes con sospecha de arritmias cardíacas. Metodología: Cohorte de 100 pacientes atendidos en la unidad de Electrofisiología cardiovascular de un centro de referencia, con sospecha de arritmia cardíaca, sin diagnóstico electrocardiográfico causal, a pesar de exámenes previos. Se les aplic

  6. The effect of endogenously released glucose, insulin, glucagon-like peptide 1, ghrelin on cardiac output, heart rate, stroke volume, and blood pressure.

    Science.gov (United States)

    Hlebowicz, Joanna; Lindstedt, Sandra; Björgell, Ola; Dencker, Magnus

    2011-12-29

    Ingestion of a meal increases the blood flow to the gastrointestinal organs and affects the heart rate (HR), blood pressure and cardiac output (CO), although the mechanisms are not known. The aim of this study was to evaluate the effect of endogenously released glucose, insulin, glucagon-like peptide 1 (GLP-1), ghrelin on CO, HR, stroke volume (SV), and blood pressure. Eleven healthy men and twelve healthy women ((mean ± SEM) aged: 26 ± 0.2 y; body mass index: 21.8 ± 0.1 kg/m(2))) were included in this study. The CO, HR, SV, systolic and diastolic blood pressure, antral area, gastric emptying rate, and glucose, insulin, GLP-1 and ghrelin levels were measured. The CO and SV at 30 min were significantly higher, and the diastolic blood pressure was significantly lower, than the fasting in both men and women (P blood pressure (P = 0.021, r = -0.681), and the change in SV (P = 0.008, r = -0.748) relative to the fasting in men. The insulin 0-30 min AUC was significantly correlated to the CO 0-30 min AUC (P = 0.002, r = 0.814) in men. Significant correlations were also found between the 0-120 min ghrelin and HR AUCs (P = 0.007, r = 0.966) in men. No statistically significant correlations were seen in women. Physiological changes in the levels of glucose, insulin, GLP-1 and ghrelin may influence the activity of the heart and the blood pressure. There may also be gender-related differences in the haemodynamic responses to postprandial changes in hormone levels. The results of this study show that subjects should not eat immediately prior to, or during, the evaluation of cardiovascular interventions as postprandial affects may affect the results, leading to erroneous interpretation of the cardiovascular effects of the primary intervention. NCT01027507.

  7. A comparison of volume clamp method-based continuous noninvasive cardiac output (CNCO) measurement versus intermittent pulmonary artery thermodilution in postoperative cardiothoracic surgery patients.

    Science.gov (United States)

    Wagner, Julia Y; Körner, Annmarie; Schulte-Uentrop, Leonie; Kubik, Mathias; Reichenspurner, Hermann; Kluge, Stefan; Reuter, Daniel A; Saugel, Bernd

    2018-04-01

    The CNAP technology (CNSystems Medizintechnik AG, Graz, Austria) allows continuous noninvasive arterial pressure waveform recording based on the volume clamp method and estimation of cardiac output (CO) by pulse contour analysis. We compared CNAP-derived CO measurements (CNCO) with intermittent invasive CO measurements (pulmonary artery catheter; PAC-CO) in postoperative cardiothoracic surgery patients. In 51 intensive care unit patients after cardiothoracic surgery, we measured PAC-CO (criterion standard) and CNCO at three different time points. We conducted two separate comparative analyses: (1) CNCO auto-calibrated to biometric patient data (CNCO bio ) versus PAC-CO and (2) CNCO calibrated to the first simultaneously measured PAC-CO value (CNCO cal ) versus PAC-CO. The agreement between the two methods was statistically assessed by Bland-Altman analysis and the percentage error. In a subgroup of patients, a passive leg raising maneuver was performed for clinical indications and we present the changes in PAC-CO and CNCO in four-quadrant plots (exclusion zone 0.5 L/min) in order to evaluate the trending ability of CNCO. The mean difference between CNCO bio and PAC-CO was +0.5 L/min (standard deviation ± 1.3 L/min; 95% limits of agreement -1.9 to +3.0 L/min). The percentage error was 49%. The concordance rate was 100%. For CNCOcal, the mean difference was -0.3 L/min (±0.5 L/min; -1.2 to +0.7 L/min) with a percentage error of 19%. In this clinical study in cardiothoracic surgery patients, CNCO cal showed good agreement when compared with PAC-CO. For CNCO bio , we observed a higher percentage error and good trending ability (concordance rate 100%).

  8. Cardiac monitoring for detection of atrial fibrillation after TIA: A systematic review and meta-analysis.

    Science.gov (United States)

    Korompoki, Eleni; Del Giudice, Angela; Hillmann, Steffi; Malzahn, Uwe; Gladstone, David J; Heuschmann, Peter; Veltkamp, Roland

    2017-01-01

    Background and purpose The detection rate of atrial fibrillation has not been studied specifically in transient ischemic attack (TIA) patients although extrapolation from ischemic stroke may be inadequate. We conducted a systematic review and meta-analysis to determine the rate of newly diagnosed atrial fibrillation using different methods of ECG monitoring in TIA. Methods A comprehensive literature search was performed following a pre-specified protocol the PRISMA statement. Prospective observational studies and randomized controlled trials were considered that included TIA patients who underwent cardiac monitoring for >12 h. Primary outcome was frequency of detection of atrial fibrillation ≥30 s. Analyses of subgroups and of duration and type of monitoring were performed. Results Seventeen studies enrolling 1163 patients were included. The pooled atrial fibrillation detection rate for all methods was 4% (95% CI: 2-7%). Yield of monitoring was higher in selected (higher age, more extensive testing for arrhythmias before enrolment, or presumed cardioembolic/cryptogenic cause) than in unselected cohorts (7% vs 3%). Pooled mean atrial fibrillation detection rates rose with duration of monitoring: 4% (24 h), 5% (24 h to 7 days) and 6% (>7 days), respectively. Yield of non-invasive was significantly lower than that of invasive monitoring (4% vs. 11%). Significant heterogeneity was observed among studies (I 2 =60.61%). Conclusion This first meta-analysis of atrial fibrillation detection in TIA patients finds a lower atrial fibrillation detection rate in TIA than reported for IS and TIA cohorts in previous meta-analyses. Prospective studies are needed to determine actual prevalence of atrial fibrillation and optimal diagnostic procedure for atrial fibrillation detection in TIA.

  9. A remote monitor of bed patient cardiac vibration, respiration and movement.

    Science.gov (United States)

    Mukai, Koji; Yonezawa, Yoshiharu; Ogawa, Hidekuni; Maki, Hiromichi; Caldwell, W Morton

    2009-01-01

    We have developed a remote system for monitoring heart rate, respiration rate and movement behavior of at-home elderly people who are living alone. The system consists of a 40 kHz ultrasonic transmitter and receiver, linear integrated circuits, a low-power 8-bit single chip microcomputer and an Internet server computer. The 40 kHz ultrasonic transmitter and receiver are installed into a bed mattress. The transmitted signal diffuses into the bed mattress, and the amplitude of the received ultrasonic wave is modulated by the shape of the mattress and parameters such as respiration, cardiac vibration and movement. The modulated ultrasonic signal is received and demodulated by an envelope detection circuit. Low, high and band pass filters separate the respiration, cardiac vibration and movement signals, which are fed into the microcontroller and digitized at a sampling rate of 50 Hz by 8-bit A/D converters. The digitized data are sent to the server computer as a serial signal. This computer stores the data and also creates a graphic chart of the latest hour. The person's family or caregiver can download this chart via the Internet at any time.

  10. A Real-Time Health Monitoring System for Remote Cardiac Patients Using Smartphone and Wearable Sensors

    Directory of Open Access Journals (Sweden)

    Priyanka Kakria

    2015-01-01

    Full Text Available Online telemedicine systems are useful due to the possibility of timely and efficient healthcare services. These systems are based on advanced wireless and wearable sensor technologies. The rapid growth in technology has remarkably enhanced the scope of remote health monitoring systems. In this paper, a real-time heart monitoring system is developed considering the cost, ease of application, accuracy, and data security. The system is conceptualized to provide an interface between the doctor and the patients for two-way communication. The main purpose of this study is to facilitate the remote cardiac patients in getting latest healthcare services which might not be possible otherwise due to low doctor-to-patient ratio. The developed monitoring system is then evaluated for 40 individuals (aged between 18 and 66 years using wearable sensors while holding an Android device (i.e., smartphone under supervision of the experts. The performance analysis shows that the proposed system is reliable and helpful due to high speed. The analyses showed that the proposed system is convenient and reliable and ensures data security at low cost. In addition, the developed system is equipped to generate warning messages to the doctor and patient under critical circumstances.

  11. A Real-Time Health Monitoring System for Remote Cardiac Patients Using Smartphone and Wearable Sensors.

    Science.gov (United States)

    Kakria, Priyanka; Tripathi, N K; Kitipawang, Peerapong

    2015-01-01

    Online telemedicine systems are useful due to the possibility of timely and efficient healthcare services. These systems are based on advanced wireless and wearable sensor technologies. The rapid growth in technology has remarkably enhanced the scope of remote health monitoring systems. In this paper, a real-time heart monitoring system is developed considering the cost, ease of application, accuracy, and data security. The system is conceptualized to provide an interface between the doctor and the patients for two-way communication. The main purpose of this study is to facilitate the remote cardiac patients in getting latest healthcare services which might not be possible otherwise due to low doctor-to-patient ratio. The developed monitoring system is then evaluated for 40 individuals (aged between 18 and 66 years) using wearable sensors while holding an Android device (i.e., smartphone under supervision of the experts). The performance analysis shows that the proposed system is reliable and helpful due to high speed. The analyses showed that the proposed system is convenient and reliable and ensures data security at low cost. In addition, the developed system is equipped to generate warning messages to the doctor and patient under critical circumstances.

  12. Enabling social listening for cardiac safety monitoring: Proceedings from a drug information association-cardiac safety research consortium cosponsored think tank.

    Science.gov (United States)

    Seifert, Harry A; Malik, Raleigh E; Bhattacharya, Mondira; Campbell, Kevin R; Okun, Sally; Pierce, Carrie; Terkowitz, Jeffrey; Turner, J Rick; Krucoff, Mitchell W; Powell, Gregory E

    2017-12-01

    This white paper provides a summary of the presentations and discussions from a think tank on "Enabling Social Listening for Cardiac Safety Monitoring" trials that was cosponsored by the Drug Information Association and the Cardiac Safety Research Consortium, and held at the White Oak headquarters of the US Food and Drug Administration on June 3, 2016. The meeting's goals were to explore current methods of collecting and evaluating social listening data and to consider their applicability to cardiac safety surveillance. Social listening is defined as the act of monitoring public postings on the Internet. It has several theoretical advantages for drug and device safety. First, these include the ability to detect adverse events that are "missed" by traditional sources and the ability to detect adverse events sooner than would be allowed by traditional sources, both by affording near-real-time access to data from culturally and geographically diverse sources. Social listening can also potentially introduce a novel patient voice into the conversation about drug safety, which could uniquely augment understanding of real-world medication use obtained from more traditional methodologies. Finally, it can allow for access to information about drug misuse and diversion. To date, the latter 2 of these have been realized. Although regulators from the Food and Drug Administration and the United Kingdom's Medicines and Healthcare Products Regulatory Agency participated in the think tank along with representatives from industry, academia, and patient groups, this article should not be construed to constitute regulatory guidance. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Cardiac Acceleration at the Onset of Exercise : A Potential Parameter for Monitoring Progress During Physical Training in Sports and Rehabilitation

    NARCIS (Netherlands)

    Hettinga, Florentina J.; Monden, Paul G.; van Meeteren, Nico L. U.; Daanen, Hein A. M.

    There is a need for easy-to-use methods to assess training progress in sports and rehabilitation research. The present review investigated whether cardiac acceleration at the onset of physical exercise (HRonset) can be used as a monitoring variable. The digital databases of Scopus and PubMed were

  14. Cardiotoxicity and Cardiac Monitoring During Adjuvant Trastuzumab in Daily Dutch Practice: A Study of the Southeast Netherlands Breast Cancer Consortium

    NARCIS (Netherlands)

    Seferina, S.C.; Boer, M. de; Derksen, M.W.J.; Berkmortel, F. van den; Kampen, R.J. van; Wouw, A.J. van de; Joore, M.; Peer, P.G.M.; Voogd, A.C.; Tjan-Heijnen, V.C.

    2016-01-01

    INTRODUCTION: We assessed the incidence and timing of first cardiac events, impact on trastuzumab prescription, and role of left ventricular ejection fraction (LVEF) monitoring in daily practice of trastuzumab-treated patients with human epidermal growth receptor 2 (HER2)-positive early breast

  15. Cardiac acceleration at the onset of exercise: A potential parameter for monitoring progress during physical training in sports and rehabilitation

    NARCIS (Netherlands)

    Hettinga, F.J.; Monden, P.G.; Meeteren, N.L.U. van; Daanen, H.A.M.

    2014-01-01

    There is a need for easy-to-use methods to assess training progress in sports and rehabilitation research. The present review investigated whether cardiac acceleration at the onset of physical exercise (HRonset) can be used as a monitoring variable. The digital databases of Scopus and PubMed were

  16. The effect of endogenously released glucose, insulin, glucagon-like peptide 1, ghrelin on cardiac output, heart rate, stroke volume, and blood pressure

    Directory of Open Access Journals (Sweden)

    Hlebowicz Joanna

    2011-12-01

    Full Text Available Abstract Background Ingestion of a meal increases the blood flow to the gastrointestinal organs and affects the heart rate (HR, blood pressure and cardiac output (CO, although the mechanisms are not known. The aim of this study was to evaluate the effect of endogenously released glucose, insulin, glucagon-like peptide 1 (GLP-1, ghrelin on CO, HR, stroke volume (SV, and blood pressure. Methods Eleven healthy men and twelve healthy women ((mean ± SEM aged: 26 ± 0.2 y; body mass index: 21.8 ± 0.1 kg/m2 were included in this study. The CO, HR, SV, systolic and diastolic blood pressure, antral area, gastric emptying rate, and glucose, insulin, GLP-1 and ghrelin levels were measured. Results The CO and SV at 30 min were significantly higher, and the diastolic blood pressure was significantly lower, than the fasting in both men and women (P P = 0.015, r = 0.946, and between ghrelin levels and HR (P = 0.013, r = 0.951 at 110 min. Significant correlations were also found between the change in glucose level at 30 min and the change in systolic blood pressure (P = 0.021, r = -0.681, and the change in SV (P = 0.008, r = -0.748 relative to the fasting in men. The insulin 0-30 min AUC was significantly correlated to the CO 0-30 min AUC (P = 0.002, r = 0.814 in men. Significant correlations were also found between the 0-120 min ghrelin and HR AUCs (P = 0.007, r = 0.966 in men. No statistically significant correlations were seen in women. Conclusions Physiological changes in the levels of glucose, insulin, GLP-1 and ghrelin may influence the activity of the heart and the blood pressure. There may also be gender-related differences in the haemodynamic responses to postprandial changes in hormone levels. The results of this study show that subjects should not eat immediately prior to, or during, the evaluation of cardiovascular interventions as postprandial affects may affect the results, leading to erroneous interpretation of the cardiovascular effects of the

  17. Clip-on wireless wearable microwave sensor for ambulatory cardiac monitoring.

    Science.gov (United States)

    Fletcher, Richard R; Kulkarni, Sarang

    2010-01-01

    We present a new type of non-contact sensor for use in ambulatory cardiac monitoring. The sensor operation is based on a microwave Doppler technique; however, instead of detecting the heart activity from a distance, the sensor is placed on the patient's chest over the clothing. The microwave sensor directly measures heart movement rather than electrical activity, and is thus complementary to ECG. The primary advantages of the microwave sensor includes small size, light weight, low power, low-cost, and the ability to operate through clothing. We present a sample sensor design that incorporates a 2.4 GHz Doppler circuit, integrated microstrip patch antenna, and microntroller with 12-bit ADC data sampling. The prototype sensor also includes a wireless data link for sending data to a remote PC or mobile phone. Sample data is shown for several subjects and compared to data from a commercial portable ECG device. Data collected from the microwave sensor exhibits a significant amount of features, indicating possible use as a tool for monitoring heart mechanics and detection of abnormalities such as fibrillation and akinesia.

  18. Cardiovascular Ultrasound of Neonatal Long Evans Rats Exposed Prenatally to Trichloroacetic Acid: Effects on Heart Rate, Ejection Fraction, and Cardiac Output

    Science.gov (United States)

    This abstract describes the use of a relatively new technology, cardiovascular ultrasound (echocardiography) for evaluating developmental toxicity affecting heart development. The abstract describes the effects of two known cardiac teratogens, trichloroacetic acid and dimethadio...

  19. Results of remote follow-up and monitoring in young patients with cardiac implantable electronic devices.

    Science.gov (United States)

    Silvetti, Massimo S; Saputo, Fabio A; Palmieri, Rosalinda; Placidi, Silvia; Santucci, Lorenzo; Di Mambro, Corrado; Righi, Daniela; Drago, Fabrizio

    2016-01-01

    Remote monitoring is increasingly used in the follow-up of patients with cardiac implantable electronic devices. Data on paediatric populations are still lacking. The aim of our study was to follow-up young patients both in-hospital and remotely to enhance device surveillance. This is an observational registry collecting data on consecutive patients followed-up with the CareLink system. Inclusion criteria were a Medtronic device implanted and patient's willingness to receive CareLink. Patients were stratified according to age and presence of congenital/structural heart defects (CHD). A total of 221 patients with a device - 200 pacemakers, 19 implantable cardioverter defibrillators, and two loop recorders--were enrolled (median age of 17 years, range 1-40); 58% of patients were younger than 18 years of age and 73% had CHD. During a follow-up of 12 months (range 4-18), 1361 transmissions (8.9% unscheduled) were reviewed by technicians. Time for review was 6 ± 2 minutes (mean ± standard deviation). Missed transmissions were 10.1%. Events were documented in 45% of transmissions, with 2.7% yellow alerts and 0.6% red alerts sent by wireless devices. No significant differences were found in transmission results according to age or presence of CHD. Physicians reviewed 6.3% of transmissions, 29 patients were contacted by phone, and 12 patients underwent unscheduled in-hospital visits. The event recognition with remote monitoring occurred 76 days (range 16-150) earlier than the next scheduled in-office follow-up. Remote follow-up/monitoring with the CareLink system is useful to enhance device surveillance in young patients. The majority of events were not clinically relevant, and the remaining led to timely management of problems.

  20. Different Modes of Monitoring and Correction of Cardiac Function During Operations Under Extracorporeal Circulation

    Directory of Open Access Journals (Sweden)

    L. A. Krichevsky

    2007-01-01

    Full Text Available Objective: to comparatively evaluate the efficiency of intensive care measures chosen on the basis of traditional monitoring of central hemodynamics (CH or on that of the data of transesophageal echocardiography (TE echoCG.Materials and methods: 50 patients were examined at coronary bypass surgery under extracorporeal circulation. Under a prospective comparative analysis were two algorithms of treatment policy: maintenance of cardiac index, by using the maximum volemic load, or that of left ventricular systolic function under guidance of transesophageal echocardiography.Results: Significantly (p<0.05 larger doses of dopamine and/or dobutamine were required to maintain adequate left ventricular systolic function. However, this treatment policy showed much better (p<0.05 circulatory parameters in the postperfusion period. At the same time the duration of postoperative inotropic therapy in these patients proved to be significantly (p<0.05 less.Conclusion. The treatment policy based on the maintenance of left ventricular systolic function under guidance of TE echoCG leads to the shortest circulatory stabilization during myocardial revascularization. The application of a volemic load and the expectant use of inotropic drugs result in a longer restoration of operated heart function. 

  1. Cardiac autonomic modulation by estrogen in female mice undergoing ambulatory monitoring and in vivo electrophysiologic testing.

    Science.gov (United States)

    Saba, Samir; Shusterman, Vladimir; Usiene, Irmute; London, Barry

    2004-04-01

    Estrogen is an important modulator of cardiovascular risk, but its mechanism of action is not fully understood. We investigated the effect of ovariectomy and its timing on the cardiac electrophysiology in mice. Thirty female mice (age 18.8 +/- 3.1 weeks) underwent in vivo electrophysiologic testing before and after autonomic blockade. Fifteen mice were ovariectomized prepuberty (PRE) and ten postpuberty (POST), 2 weeks prior to electrophysiologic testing. Five age-matched sham-operated female mice (Control) served as controls. A subset of 13 mice (5 PRE, 3 POST, and 5 Controls) underwent 24-hour ambulatory monitoring. With ambulatory monitoring, the average (668 +/- 28 vs 769 +/- 52 b/min, P = 0.008) and minimum (485 +/- 47 vs 587 +/- 53 b/min, P = 0.02) heart rates were significantly slower in the ovariectomized mice (PRE and POST groups) compared to the Control group. At baseline electrophysiologic testing, there were no significant differences among the ovariectomized and intact mice in any of the measured parameters. With autonomic blockade, the Control group had a significantly larger change (delta) in the atrioventricular (AV) nodal Wenckebach (AVW) periodicity (deltaAVW = 11.3 +/- 2.9 vs 2.1 +/- 7.3 ms, P = 0.05) and functional refractory period (deltaFRP = 11.3 +/- 2.1 vs 1.25 +/- 6.8 ms, P = 0.02) compared to the ovariectomized mice. These results were not altered by the time of ovariectomy (PRE vs POST groups). Our results suggest that estrogen modulates the autonomic inputs into the murine sinus and AV nodes. These findings, if replicated in humans, might underlie the observed clustering of certain arrhythmias around menstruation and explain the higher incidence of arrhythmias in men and postmenopausal women.

  2. Mobile Cardiac Health-care Monitoring and Notification with Real Time Tachycardia and Bradycardia Arrhythmia Detection.

    Science.gov (United States)

    Golzar, Mina; Fotouhi-Ghazvini, Faranak; Rabbani, Hossein; Zakeri, Fahimeh Sadat

    2017-01-01

    The increasing trend of heart disease has turned the attention of researchers toward the use of portable connected technologies. The necessity of continuous special care for cardiovascular patients is an inevitable fact. In this research, a new wireless electrocardiographic (ECG) signal-monitoring system based on smartphone is presented. This system has two main sections. The first section consists of a sensor which receives ECG signals via an amplifier, then filters and digitizes the signal, and prepares it to be transmitted. The signals are stored, processed, and then displayed in a mobile application. The application alarms in dangerous situations and sends the location of the cardiac patient to family or health-care staff. The results obtained from the analysis of the electrocardiogram signals on 20 different people have been compared with the traditional ECG in hospital by a cardiologist. The signal is instantly transmitted by 200 sample per second to mobile phone. The raw data are processed, the anomaly is detected, and the signal is drawn on the interface in about 70 s. Therefore, the delay is not noticeable by the patient. With respect to rate of data transmission to hospital, different internet connections such as 2G, 3G, 4G, WiFi, WiMax, or Long-Term Evolution (LTE) could be used. Data transmission ranges from 9.6 kbps to 20 Mbps. Therefore, the physician could receive data with no delay. A performance accuracy of 91.62% is obtained from the wireless ECG system. It conforms to the hospital's diagnostic standard system while providing a portable monitoring anywhere at anytime.

  3. Differential-output B-dot and D-dot monitors for current and voltage measurements on a 20-MA, 3-MV pulsed-power accelerator

    Directory of Open Access Journals (Sweden)

    T. C. Wagoner

    2008-10-01

    Full Text Available We have developed a system of differential-output monitors that diagnose current and voltage in the vacuum section of a 20-MA 3-MV pulsed-power accelerator. The system includes 62 gauges: 3 current and 6 voltage monitors that are fielded on each of the accelerator’s 4 vacuum-insulator stacks, 6 current monitors on each of the accelerator’s 4 outer magnetically insulated transmission lines (MITLs, and 2 current monitors on the accelerator’s inner MITL. The inner-MITL monitors are located 6 cm from the axis of the load. Each of the stack and outer-MITL current monitors comprises two separate B-dot sensors, each of which consists of four 3-mm-diameter wire loops wound in series. The two sensors are separately located within adjacent cavities machined out of a single piece of copper. The high electrical conductivity of copper minimizes penetration of magnetic flux into the cavity walls, which minimizes changes in the sensitivity of the sensors on the 100-ns time scale of the accelerator’s power pulse. A model of flux penetration has been developed and is used to correct (to first order the B-dot signals for the penetration that does occur. The two sensors are designed to produce signals with opposite polarities; hence, each current monitor may be regarded as a single detector with differential outputs. Common-mode-noise rejection is achieved by combining these signals in a 50-Ω balun. The signal cables that connect the B-dot monitors to the balun are chosen to provide reasonable bandwidth and acceptable levels of Compton drive in the bremsstrahlung field of the accelerator. A single 50-Ω cable transmits the output signal of each balun to a double-wall screen room, where the signals are attenuated, digitized (0.5-ns/sample, numerically compensated for cable losses, and numerically integrated. By contrast, each inner-MITL current monitor contains only a single B-dot sensor. These monitors are fielded in opposite-polarity pairs. The two

  4. Input-output supervisor

    International Nuclear Information System (INIS)

    Dupuy, R.

    1970-01-01

    The input-output supervisor is the program which monitors the flow of informations between core storage and peripheral equipments of a computer. This work is composed of three parts: 1 - Study of a generalized input-output supervisor. With sample modifications it looks like most of input-output supervisors which are running now on computers. 2 - Application of this theory on a magnetic drum. 3 - Hardware requirement for time-sharing. (author) [fr

  5. Burnout versus work engagement in their effects on 24-hour ambulatory monitored cardiac autonomic function

    NARCIS (Netherlands)

    L.J.P. van Doornen (Lorenz); J.H. Houtveen (Jan); S. Langelaan (Saar); A.B. Bakker (Arnold); W. van Rhenen (Willem); W.B. Schaufeli (Wilmar)

    2009-01-01

    textabstractBurnout has been associated with increased risk of cardiovascular disease. This relationship may be mediated by a stress-related disruption in cardiac autonomic activity. The aim of the present study was to assess cardiac autonomic activity (sympathetic and parasympathetic) during a

  6. Aortic and Hepatic Contrast Enhancement During Hepatic-Arterial and Portal Venous Phase Computed Tomography Scanning: Multivariate Linear Regression Analysis Using Age, Sex, Total Body Weight, Height, and Cardiac Output.

    Science.gov (United States)

    Masuda, Takanori; Nakaura, Takeshi; Funama, Yoshinori; Higaki, Toru; Kiguchi, Masao; Imada, Naoyuki; Sato, Tomoyasu; Awai, Kazuo

    We evaluated the effect of the age, sex, total body weight (TBW), height (HT) and cardiac output (CO) of patients on aortic and hepatic contrast enhancement during hepatic-arterial phase (HAP) and portal venous phase (PVP) computed tomography (CT) scanning. This prospective study received institutional review board approval; prior informed consent to participate was obtained from all 168 patients. All were examined using our routine protocol; the contrast material was 600 mg/kg iodine. Cardiac output was measured with a portable electrical velocimeter within 5 minutes of starting the CT scan. We calculated contrast enhancement (per gram of iodine: [INCREMENT]HU/gI) of the abdominal aorta during the HAP and of the liver parenchyma during the PVP. We performed univariate and multivariate linear regression analysis between all patient characteristics and the [INCREMENT]HU/gI of aortic- and liver parenchymal enhancement. Univariate linear regression analysis demonstrated statistically significant correlations between the [INCREMENT]HU/gI and the age, sex, TBW, HT, and CO (all P linear regression analysis showed that only the TBW and CO were of independent predictive value (P linear regression analysis only the TBW and CO were significantly correlated with aortic and liver parenchymal enhancement; the age, sex, and HT were not. The CO was the only independent factor affecting aortic and liver parenchymal enhancement at hepatic CT when the protocol was adjusted for the TBW.

  7. The use of an improved technique to reduce the variability of output voltage in real-time Fibre Bragg Grating based monitoring system

    Science.gov (United States)

    Vorathin, E.; Hafizi, Z. M.; Che Ghani, S. A.; Lim, K. S.; Aizzuddin, A. M.

    2017-10-01

    Fibre Bragg Grating (FBG) sensors have been widely utilized in the structural health monitoring (SHM) of structures. However, one of the main challenges of FBGs is the existence of inconsistency in output voltage during wavelength intensity demodulation utilizing photodetector (PD) to convert the light signal into digital voltage readings. Thus, the designation of this experimental work is to develop a robust FBG real-time monitoring system with the benefit of MATLAB graphical user interface (GUI) and voltage normalization algorithm to scale down the voltage inconsistency. Low-cost edge filter interrogation system has been practiced in the experimentation and splitter optical component is make use to reduce the intensity of the high power light source that leads to the formation of noise due to unwanted reflected wavelengths. The results revealed that with the advancement of the proposed monitoring system, the sensitivity of the FBG has been increased from 2.4 mV/N to 3.8 mV/N across the range of 50 N. The redundancy in output voltage variation data points has been reduced from 26 data/minute to 17 data/minute. The accuracy of the FBG in detecting the load induced falls in the acceptable range of total average error which is 1.38 %.

  8. Implementing an institution-wide quality improvement policy to ensure appropriate use of continuous cardiac monitoring: a mixed-methods retrospective data analysis and direct observation study.

    Science.gov (United States)

    Rayo, Michael F; Mansfield, Jerry; Eiferman, Daniel; Mignery, Traci; White, Susan; Moffatt-Bruce, Susan D

    2016-10-01

    Hospitals have been slow to adopt guidelines from the American Heart Association (AHA) limiting the use of continuous cardiac monitoring for fear of missing important patient cardiac events. A new continuous cardiac monitoring policy was implemented at a tertiary-care hospital seeking to monitor only those patients who were clinically indicated and decrease the number of false alarms in order to improve overall alarm response. Leadership support was secured, a cross-functional alarm management task force was created, and a system-wide policy was developed based on current AHA guidelines. Process measures, including cardiac monitoring rate, monitored transport rate, emergency department (ED) boarding rate and the percentage of false, unnecessary and true alarms, were measured to determine the policy's impact on patient care. Outcome measures, including length of stay and mortality rate, were measured to determine the impact on patient outcomes. Cardiac monitoring rate decreased 53.2% (0.535 to 0.251 per patient day, pimprovements in process measures coupled with no adverse effects to patient outcomes suggest that the overall system became more resilient to current and emerging demands. This study indicates that when collaboration across a diverse team is coupled with strong leadership support, policies and procedures such as this one can improve clinical practice and patient care. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  9. Prolonged Cardiac Monitoring to Detect Atrial Fibrillation after Cryptogenic Stroke or Transient Ischemic Attack: A Meta-Analysis of Randomized Controlled Trials.

    Science.gov (United States)

    Dahal, Khagendra; Chapagain, Bikas; Maharjan, Raju; Farah, Hussam W; Nazeer, Ayesha; Lootens, Robert J; Rosenfeld, Alan

    2016-07-01

    The cause of ischemic stroke or transient ischemic attack (TIA) remains unclear after initial cardiac monitoring in approximately one-third of patients. Randomized controlled trials (RCTs) showed that the prolonged cardiac monitoring of patients with cryptogenic stroke or TIA increased detection of atrial fibrillation (AF). We aimed to perform a meta-analysis of all RCTs that evaluated the prolonged monitoring ≥7 days in patients with cryptogenic stroke or TIA. We searched PubMed, EMBASE, Cochrane CENTRAL, and relevant references for RCTs without language restriction (inception through December 2014) and performed meta-analysis using random effects model. Detection of AF, use of anticoagulation at follow-up, recurrent stroke or TIA, and mortality were major outcomes. Four RCTs with 1149 total patients were included in the meta-analysis. Prolonged cardiac monitoring ≥7 days compared to shorter cardiac monitoring of ≤48 hours duration increased the detection of AF (≥30 seconds duration) in patients after cryptogenic stroke or TIA (13.8% vs. 2.5%; odds ratio [OR], 6.4; 95% confidence interval [CI], 3.50-11.73; P vs. 5.2%; 5.68[3.3-9.77]; P stroke or TIA (0.78[0.40-1.55]; P = 0.48; I(2) , 0%) and mortality (1.33[0.29-6.00]; P = 0.71; I(2) , 0%] were observed between two strategies. Prolonged cardiac monitoring improves detection of atrial fibrillation and anti-coagulation use after cryptogenic stroke or TIA and therefore should be considered instead of shorter duration of cardiac monitoring. © 2015 Wiley Periodicals, Inc.

  10. Microfluidic system for monitoring of cardiac (H9C2) cell proliferation

    Science.gov (United States)

    Kobuszewska, A.; Cwik, P.; Jastrzebska, E.; Brzozka, Z.; Chudy, M.; Renaud, P.; Dybko, A.

    2017-05-01

    The paper presents the application of electrical impedance spectroscopy (EIS) analysis for investigation of cardiac cell (H9C2 - rat cardiomyoblast) proliferation after verapamil hydrochloride exposure. For this purpose, two different PDMS/glass microsystems with circular microchamber and longitudinal microchannel integrated with Pt/Al electrodes were used. The microchambers were fabricated in PDMS using photolithography and replica moulding techniques. Pt/Al electrodes were fabricated on a 4-inch glass substrate using Physical Vapor Deposition (PVD). Solution of verapamil hydrochloride was continuously introduced into the microsystems with H9C2 cell culture (a flow rate of 1 μl/min) for 72 h. The impedance spectra were recorded from 100 Hz to 1 MHz. We confirmed that impedance spectroscopy can be used for non-invasive, label-free and real-time analysis of cardiac cells proliferation based on cells dielectric properties and biological structure.

  11. Cardiac gated ventilation

    International Nuclear Information System (INIS)

    Hanson, C.W. III; Hoffman, E.A.

    1995-01-01

    There are several theoretic advantages to synchronizing positive pressure breaths with the cardiac cycle, including the potential for improving distribution of pulmonary and myocardial blood flow and enhancing cardiac output. The authors evaluated the effects of synchronizing respiration to the cardiac cycle using a programmable ventilator and electron beam CT (EBCT) scanning. The hearts of anesthetized dogs were imaged during cardiac gated respiration with a 50 msec scan aperture. Multi slice, short axis, dynamic image data sets spanning the apex to base of the left ventricle were evaluated to determine the volume of the left ventricular chamber at end-diastole and end-systole during apnea, systolic and diastolic cardiac gating. The authors observed an increase in cardiac output of up to 30% with inspiration gated to the systolic phase of the cardiac cycle in a non-failing model of the heart

  12. Yonjung High-Speed Railway Bridge Assessment Using Output-Only Structural Health Monitoring Measurements under Train Speed Changing

    Directory of Open Access Journals (Sweden)

    Mosbeh R. Kaloop

    2016-01-01

    Full Text Available Yonjung Bridge is a hybrid multispan bridge that is designed to transport high-speed trains (HEMU-430X with maximum operating speed of 430 km/h. The bridge consists of simply supported prestressed concrete (PSC and composite steel girders to carry double railway tracks. The structural health monitoring system (SHM is designed and installed to investigate and assess the performance of the bridge in terms of acceleration and deformation measurements under different speeds of the passing train. The SHM measurements are investigated in both time and frequency domains; in addition, several identification models are examined to assess the performance of the bridge. The drawn conclusions show that the maximum deflection and acceleration of the bridge are within the design limits that are specified by the Korean and European codes. The parameters evaluation of the model identification depicts the quasistatic and dynamic deformations of PSC and steel girders to be different and less correlated when higher speeds of the passing trains are considered. Finally, the variation of the frequency content of the dynamic deformations of the girders is negligible when high speeds are considered.

  13. Infant Motor Skills After a Cardiac Operation: The Need for Developmental Monitoring and Care.

    Science.gov (United States)

    Uzark, Karen; Smith, Cynthia; Donohue, Janet; Yu, Sunkyung; Romano, Jennifer C

    2017-08-01

    Neurodevelopmental dysfunction is increasingly recognized as a common outcome of congenital heart defects and their treatment in infancy. The effects of the intensive care unit (ICU) experience and environment on these infants are unknown and potentially modifiable, but no validated metric is available for objective evaluation of early motor impairments in the ICU/hospital setting. The purpose of this study was to characterize the motor status of hospitalized infants after cardiac operations, including the development and field-testing of the Congenital Heart Assessment of Sensory and Motor Status (CHASMS) metric. CHASMS item generation was based on review of the literature, focused interviews with parents, and expert consensus. A nurse administered CHASMS to 100 infants aged younger than 10 months old undergoing cardiac operations. Preoperative and postoperative CHASMS scores were compared, and associations between CHASMS scores and patient characteristics were examined. Physical therapists assessed neuromotor skills by using the Test of Infant Motor Performance or the Alberta Infant Motor Scales for correlation with CHASMS scores. CHASMS gross motor scores declined postoperatively in 64% (25 of 39). Lower CHASMS scores, after adjusting for age, were associated with longer duration of mechanical ventilation (p motor CHASMS scores were significantly correlated with Test of Infant Motor Performance (r = 0.70, p Motor Scales scores (r = 0.88, p Motor impairments in infants after cardiac operations are common and may be exacerbated by longer intubation and prolonged exposure to the ICU environment. The feasibility, reliability, and validity of CHASMS were supported for the evaluation of motor skills in this at-risk population. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Cardiac monitoring during adjuvant trastuzumab therapy: Guideline adherence in clinical practice

    NARCIS (Netherlands)

    Visser, Annemiek; van de Ven, Eline M. W.; Ruczynski, Larissa I. A.; Blaisse, Reinoud J. B.; van Halteren, Henk K.; Aben, Katja; van Laarhoven, Hanneke W. M.

    2016-01-01

    Cardiotoxicity is an important adverse effect of adjuvant breast cancer treatment with trastuzumab and three monthly left ventricular ejection fraction (LVEF) monitoring is considered mandatory. The purpose of this study was to gain insight into LVEF monitoring during adjuvant trastuzumab treatment

  15. Emerging role of digital technology and remote monitoring in the care of cardiac patients.

    Science.gov (United States)

    Banchs, Javier E; Scher, David Lee

    2015-07-01

    Current available mobile health technologies make possible earlier diagnosis and long-term monitoring of patients with cardiovascular diseases. Remote monitoring of patients with implantable devices and chronic diseases has resulted in better outcomes reducing health care costs and hospital admissions. New care models, which shift point of care to the outpatient setting and the patient's home, necessitate innovations in technology. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. The effect of siesta in parameters of cardiac structure and in interpretation of ambulatory arterial blood pressure monitoring

    Directory of Open Access Journals (Sweden)

    Marco A.M. Gomes

    2000-04-01

    Full Text Available OBJECTIVE: To evaluate the influence of the siesta in ambulatory blood pressure (BP monitoring and in cardiac structure parameters. METHODS: 1940 ambulatory arterial blood pressure monitoring tests were analyzed (Spacelabs 90207, 15/15 minutes from 7:00 to 22:00 hours and 20/20 minutes from 22:01 to 6.59hours and 21% of the records indicated that the person had taken a siesta (263 woman, 52±14 years. The average duration of the siesta was 118±58 minutes. RESULTS: (average ± standard deviation The average of systolic/diastolic pressures during wakefulness, including the napping period, was less than the average for the period not including the siesta (138±16/85±11 vs 139±16/86±11 mmHg, p5%. CONCLUSION: The siesta influenced the heart structure parameters and from a statistical point of view the average of systolic and diastolic pressures and the respective pressure loads of the wakeful period.

  17. [Extension of cardiac monitoring function by used of ordinary ECG machine].

    Science.gov (United States)

    Chen, Zhencheng; Jiang, Yong; Ni, Lili; Wang, Hongyan

    2002-06-01

    This paper deals with a portable monitor system on liquid crystal display (LCD) based on this available ordinary ECG machine, which is low power and suitable for China's specific condition. Apart from developing the overall scheme of the system, this paper also has completed the design of the hardware and the software. The 80c196 single chip microcomputer is taken as the central microprocessor and real time electrocardiac single is data treated and analyzed in the system. With the performance of ordinary monitor, this machine also possesses the following functions: five types of arrhythmia analysis, alarm, freeze, and record of automatic pappering, convenient in carrying, with alternate-current (AC) or direct-current (DC) powered. The hardware circuit is simplified and the software structure is optimized in this paper. Multiple low power designs and LCD unit design are adopted and completed in it. Popular in usage, low in cost price, the portable monitor system will have a valuable influence on China's monitor system field.

  18. Boron-doped nanocrystalline diamond microelectrode arrays monitor cardiac action potentials.

    Science.gov (United States)

    Maybeck, Vanessa; Edgington, Robert; Bongrain, Alexandre; Welch, Joseph O; Scorsone, Emanuel; Bergonzo, Philippe; Jackman, Richard B; Offenhäusser, Andreas

    2014-02-01

    The expansion of diamond-based electronics in the area of biological interfacing has not been as thoroughly explored as applications in electrochemical sensing. However, the biocompatibility of diamond, large safe electrochemical window, stability, and tunable electronic properties provide opportunities to develop new devices for interfacing with electrogenic cells. Here, the fabrication of microelectrode arrays (MEAs) with boron-doped nanocrystalline diamond (BNCD) electrodes and their interfacing with cardiomyocyte-like HL-1 cells to detect cardiac action potentials are presented. A nonreductive means of structuring doped and undoped diamond on the same substrate is shown. The resulting BNCD electrodes show high stability under mechanical stress generated by the cells. It is shown that by fabricating the entire surface of the MEA with NCD, in patterns of conductive doped, and isolating undoped regions, signal detection may be improved up to four-fold over BNCD electrodes passivated with traditional isolators. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. A sneak peek into digital innovations and wearable sensors for cardiac monitoring.

    Science.gov (United States)

    Michard, Frederic

    2017-04-01

    Many mobile phone or tablet applications have been designed to control cardiovascular risk factors (obesity, smoking, sedentary lifestyle, diabetes and hypertension) or to optimize treatment adherence. Some have been shown to be useful but the long-term benefits remain to be demonstrated. Digital stethoscopes make easier the interpretation of abnormal heart sounds, and the development of pocket-sized echo machines may quickly and significantly expand the use of ultrasounds. Daily home monitoring of pulmonary artery pressures with wireless implantable sensors has been shown to be associated with a significant decrease in hospital readmissions for heart failure. There are more and more non-invasive, wireless, and wearable sensors designed to monitor heart rate, heart rate variability, respiratory rate, arterial oxygen saturation, and thoracic fluid content. They have the potential to change the way we monitor and treat patients with cardiovascular diseases in the hospital and beyond. Some may have the ability to improve quality of care, decrease the number of medical visits and hospitalization, and ultimately health care costs. Validation and outcome studies are needed to clarify, among the growing number of digital innovations and wearable sensors, which tools have real clinical value.

  20. Miniaturized Human Insertable Cardiac Monitoring System with Wireless Power Transmission Technique

    Directory of Open Access Journals (Sweden)

    Jong-Ha Lee

    2016-01-01

    Full Text Available Prolonged monitoring is more likely to diagnose atrial fibrillation accurately than intermittent or short-term monitoring. In this study, an implantable electrocardiograph (ECG sensor to monitor atrial fibrillation patients in real time was developed. The implantable sensor is composed of a micro controller unit, an analog-to-digital converter, a signal transmitter, an antenna, and two electrodes. The sensor detects ECG signals from the two electrodes and transmits these to an external receiver carried by the patient. Because the sensor continuously transmits signals, its battery consumption rate is extremely high; therefore, the sensor includes a wireless power transmission module that allows it to charge wirelessly from an external power source. The integrated sensor has the approximate dimensions 3 mm × 4 mm × 14 mm, which is small enough to be inserted into a patient without the need for major surgery. The signal and power transmission data sampling rate and frequency of the unit are 300 samples/s and 430 Hz, respectively. To validate the developed sensor, experiments were conducted on small animals.

  1. S3 guidelines for intensive care in cardiac surgery patients: hemodynamic monitoring and cardiocirculary system

    Directory of Open Access Journals (Sweden)

    Schmitt, D. V.

    2010-01-01

    Full Text Available Hemodynamic monitoring and adequate volume-therapy, as well as the treatment with positive inotropic drugs and vasopressors are the basic principles of the postoperative intensive care treatment of patient after cardiothoracic surgery. The goal of these S3 guidelines is to evaluate the recommendations in regard to evidence based medicine and to define therapy goals for monitoring and therapy. In context with the clinical situation the evaluation of the different hemodynamic parameters allows the development of a therapeutic concept and the definition of goal criteria to evaluate the effect of treatment. Up to now there are only guidelines for subareas of postoperative treatment of cardiothoracic surgical patients, like the use of a pulmonary artery catheter or the transesophageal echocardiography. The German Society for Thoracic and Cardiovascular Surgery (Deutsche Gesellschaft für Thorax-, Herz- und Gefäßchirurgie, DGTHG and the German Society for Anaesthesiology and Intensive Care Medicine (Deutsche Gesellschaft für Anästhesiologie und lntensivmedizin, DGAI made an approach to ensure and improve the quality of the postoperative intensive care medicine after cardiothoracic surgery by the development of S3 consensus-based treatment guidelines. Goal of this guideline is to assess the available monitoring methods with regard to indication, procedures, predication, limits, contraindications and risks for use. The differentiated therapy of volume-replacement, positive inotropic support and vasoactive drugs, the therapy with vasodilatators, inodilatators and calcium sensitizers and the use of intra-aortic balloon pumps will also be addressed. The guideline has been developed following the recommendations for the development of guidelines by the Association of the Scientific Medical Societies in Germany (AWMF. The presented key messages of the guidelines were approved after two consensus meetings under the moderation of the Association of the

  2. [The design of a cardiac monitoring and analysing system with low power consumption].

    Science.gov (United States)

    Chen, Zhen-cheng; Ni, Li-li; Zhu, Yan-gao; Wang, Hong-yan; Ma, Yan

    2002-07-01

    The paper deals with a portable analyzing monitor system with liquid crystal display (LCD), which is low in power consumption and suitable for China's specific conditions. Apart from the development of the overall scheme of the system, the paper introduces the design of the hardware and the software. The 80196 single chip microcomputer is used as the central microprocessor to process and real-time electrocardiac signal data. The system have the following functions: five types of arrhythmia analysis, alarm, freeze, and record of automatic paperfeeding. The portable system can be operated by alternate-current (AC) or direct-current (DC). Its hardware circuit is simplified and its software structure is optimized. Multiple low power consumption and LCD unit are adopted in its modular designs.

  3. Adapting detection sensitivity based on evidence of irregular sinus arrhythmia to improve atrial fibrillation detection in insertable cardiac monitors.

    Science.gov (United States)

    Pürerfellner, Helmut; Sanders, Prashanthan; Sarkar, Shantanu; Reisfeld, Erin; Reiland, Jerry; Koehler, Jodi; Pokushalov, Evgeny; Urban, Luboš; Dekker, Lukas R C

    2017-10-03

    Intermittent change in p-wave discernibility during periods of ectopy and sinus arrhythmia is a cause of inappropriate atrial fibrillation (AF) detection in insertable cardiac monitors (ICM). To address this, we developed and validated an enhanced AF detection algorithm. Atrial fibrillation detection in Reveal LINQ ICM uses patterns of incoherence in RR intervals and absence of P-wave evidence over a 2-min period. The enhanced algorithm includes P-wave evidence during RR irregularity as evidence of sinus arrhythmia or ectopy to adaptively optimize sensitivity for AF detection. The algorithm was developed and validated using Holter data from the XPECT and LINQ Usability studies which collected surface electrocardiogram (ECG) and continuous ICM ECG over a 24-48 h period. The algorithm detections were compared with Holter annotations, performed by multiple reviewers, to compute episode and duration detection performance. The validation dataset comprised of 3187 h of valid Holter and LINQ recordings from 138 patients, with true AF in 37 patients yielding 108 true AF episodes ≥2-min and 449 h of AF. The enhanced algorithm reduced inappropriately detected episodes by 49% and duration by 66% with adapts sensitivity for AF detection reduced inappropriately detected episodes and duration with minimal reduction in sensitivity. © The Author 2017. Published by Oxford University Press on behalf of the European Society of Cardiology

  4. Protocol-driven remote monitoring of cardiac resynchronization therapy as part of a heart failure disease management strategy.

    Science.gov (United States)

    Smeets, Christophe J P; Verbrugge, Frederik H; Vranken, Julie; Van der Auwera, Jo; Mullens, Wilfried; Dupont, Matthias; Grieten, Lars; De Cannière, Hélène; Lanssens, Dorien; Vandenberk, Thijs; Storms, Valerie; Thijs, Inge M; Vandervoort, Pieter

    2017-08-14

    Cardiac resynchronisation therapy (CRT) is an established treatment for heart failure (HF) with reduced ejection fraction. CRT devices are equipped with remote monitoring functions, which are pivotal in the detection of device problems, but may also facilitate disease management. The aim of this study was to provide a comprehensive overview of the clinical interventions taken based on remote monitoring. This is a single centre observational study of consecutive CRT patients (n = 192) participating in protocol-driven remote follow-up. Incoming technical- and disease-related alerts were analysed together with subsequently triggered interventions. During 34 ± 13 months of follow-up, 1372 alert-containing notifications were received (2.53 per patient-year of follow-up), comprising 1696 unique alerts (3.12 per patient-year of follow-up). In 60%, notifications resulted in a phone contact. Technical alerts constituted 8% of incoming alerts (0.23 per patient-year of follow-up). Rhythm (1.43 per patient-year of follow-up) and bioimpedance alerts (0.98 per patient-year of follow-up) were the most frequent disease-related alerts. Notifications included a rhythm alert in 39%, which triggered referral to the emergency room (4%), outpatient cardiology clinic (36%) or general practitioner (7%), or resulted in medication changes (13%). Sole bioimpedance notifications resulted in a telephone contact in 91%, which triggered outpatient evaluation in 8% versus medication changes in 10%. Clinical outcome was excellent with 97% 1-year survival. Remote CRT follow-up resulted in 0.23 technical- versus 2.64 disease-related alerts annually. Rhythm and bioimpedance notifications constituted the majority of incoming notifications which triggered an actual intervention in 22% and 15% of cases, respectively.

  5. Validation, optimisation, and application data in support of the development of a targeted selected ion monitoring assay for degraded cardiac troponin T

    Directory of Open Access Journals (Sweden)

    Alexander S. Streng

    2016-06-01

    Full Text Available Cardiac troponin T (cTnT fragmentation in human serum was investigated using a newly developed targeted selected ion monitoring assay, as described in the accompanying article: “Development of a targeted selected ion monitoring assay for the elucidation of protease induced structural changes in cardiac troponin T” [1]. This article presents data describing aspects of the validation and optimisation of this assay. The data consists of several figures, an excel file containing the results of a sequence identity search, and a description of the raw mass spectrometry (MS data files, deposited in the ProteomeXchange repository with id PRIDE: http://www.ebi.ac.uk/pride/archive/projects/PXD003187.

  6. Remote Monitoring of the Heart Condition of Athletes by Measuring the Cardiac Action Potential Propagation Time Using a Wireless Sensor Network

    Directory of Open Access Journals (Sweden)

    Amang Sudarsono

    2016-04-01

    Full Text Available Highly performing athletes are susceptible to cardiac damage of several kinds which may be irreversible. The monitoring of heart rate and ECG waveforms from such subjects by wireless sensor networks has been reported in health and sports care documents. However, a more decisive parameter for instant to instant changes would be the time of Cardiac Action Potential Propagation. This time, which can be between 15-20 ms would shoot suddenly in acute stress in highly performing athletes for short durations. Repeated incidents of such rising values will tend to cause irreversible damage to the heart. We developed the technique of measuring this time and reporting it through a wireless sensor network to monitoring station.

  7. Monitoring cognitive and emotional processes through pupil and cardiac response during dynamic versus logical task.

    Science.gov (United States)

    Causse, Mickaël; Sénard, Jean-Michel; Démonet, Jean François; Pastor, Josette

    2010-06-01

    The paper deals with the links between physiological measurements and cognitive and emotional functioning. As long as the operator is a key agent in charge of complex systems, the definition of metrics able to predict his performance is a great challenge. The measurement of the physiological state is a very promising way but a very acute comprehension is required; in particular few studies compare autonomous nervous system reactivity according to specific cognitive processes during task performance and task related psychological stress is often ignored. We compared physiological parameters recorded on 24 healthy subjects facing two neuropsychological tasks: a dynamic task that require problem solving in a world that continually evolves over time and a logical task representative of cognitive processes performed by operators facing everyday problem solving. Results showed that the mean pupil diameter change was higher during the dynamic task; conversely, the heart rate was more elevated during the logical task. Finally, the systolic blood pressure seemed to be strongly sensitive to psychological stress. A better taking into account of the precise influence of a given cognitive activity and both workload and related task-induced psychological stress during task performance is a promising way to better monitor operators in complex working situations to detect mental overload or pejorative stress factor of error.

  8. Real-time optical monitoring of permanent lesion progression in radiofrequency ablated cardiac tissue (Conference Presentation)

    Science.gov (United States)

    Singh-Moon, Rajinder P.; Hendon, Christine P.

    2016-02-01

    Despite considerable advances in guidance of radiofrequency ablation (RFA) therapies for atrial fibrillation, success rates have been hampered by an inability to intraoperatively characterize the extent of permanent injury. Insufficient lesions can elusively create transient conduction blockages that eventually reconduct. Prior studies suggest significantly greater met-myoglobin (Mmb) concentrations in the lesion core than those in the healthy myocardium and may serve as a marker for irreversible tissue damage. In this work, we present real-time monitoring of permanent injury through spectroscopic assessment of Mmb concentrations at the catheter tip. Atrial wedges (n=6) were excised from four fresh swine hearts and submerged under pulsatile flow of warm (37oC) phosphate buffered saline. A commercial RFA catheter inserted into a fiber optic sheath allowed for simultaneous measurement of tissue diffuse reflectance (DR) spectra (500-650nm) during application of RF energy. Optical measurements were continuously acquired before, during, and post-ablation, in addition to healthy neighboring tissue. Met-myoglobin, oxy-myoglobin, and deoxy-myoglobin concentrations were extracted from each spectrum using an inverse Monte Carlo method. Tissue injury was validated with Masson's trichrome and hematoxylin and eosin staining. Time courses revealed a rapid increase in tissue Mmb concentrations at the onset of RFA treatment and a gradual plateauing thereafter. Extracted Mmb concentrations were significantly greater post-ablation (p<0.0001) as compared to healthy tissue and correlated well with histological assessment of severe thermal tissue destruction. On going studies are aimed at integrating these findings with prior work on near infrared spectroscopic lesion depth assessment. These results support the use of spectroscopy-facilitated guidance of RFA therapies for real-time permanent injury estimation.

  9. Bedside Monitoring of Cerebral Energy State During Cardiac Surgery-A Novel Approach Utilizing Intravenous Microdialysis.

    Science.gov (United States)

    Mölström, Simon; Nielsen, Troels H; Andersen, Claus; Nordström, Carl H; Toft, Palle

    2017-08-01

    This study investigated whether the lactate-to-pyruvate (LP) ratio obtained by microdialysis (MD) of the cerebral venous outflow reflected a derangement of global cerebral energy state during cardiopulmonary bypass (CPB). Interventional, prospective, randomized study. Single-center, university teaching hospital. The study included 10 patients undergoing primary, elective coronary artery bypass grafting. Patients were randomized blindly to low mean arterial pressure (MAP) (40-60 mmHg; n = 5) or high MAP (60-80 mmHg; n = 5) during CPB. The MD catheters were positioned in a retrograde direction into the jugular bulb, and a reference catheter was inserted into the brachial artery. The correlations among LP ratio, MAP, data obtained from bifrontal near-infrared spectroscopy (NIRS), and postoperative neurologic outcome measures were assessed. The correlated difference between pooled LP ratio (low and high MAP) of the jugular venous and the arterial blood was significant (LP arterial 17 [15-20] v LP venous 26 [23-27]; p = 0.0001). No cerebral desaturations (decrease in rSO 2 >20% from baseline) were observed in either group during CPB. In each group, 50% of the patients showed significant cognitive decline (mini-mental state examination, 3 points) 2 days after surgery. The LP ratio of cerebral venous blood increased significantly during CPB, indicating compromised cerebral oxidative metabolism. Conventional monitoring of rSO 2 by NIRS did not show a corresponding decrease in cerebral oxygenation. As the patients exhibited decreased cognitive functions after CPB, increases in jugular venous LP ratio may be a sensitive indicator of impending cerebral damage. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Cardiac acceleration at the onset of exercise: a potential parameter for monitoring progress during physical training in sports and rehabilitation.

    Science.gov (United States)

    Hettinga, Florentina J; Monden, Paul G; van Meeteren, Nico L U; Daanen, Hein A M

    2014-05-01

    There is a need for easy-to-use methods to assess training progress in sports and rehabilitation research. The present review investigated whether cardiac acceleration at the onset of physical exercise (HRonset) can be used as a monitoring variable. The digital databases of Scopus and PubMed were searched to retrieve studies investigating HRonset. In total 652 studies were retrieved. These articles were then classified as having emphasis on HRonset in a sports or rehabilitation setting, which resulted in 8 of 112 studies with a sports application and 6 of 68 studies with a rehabilitation application that met inclusion criteria. Two co-existing mechanisms underlie HRonset: feedforward (central command) and feedback (mechanoreflex, metaboreflex, baroreflex) control. A number of studies investigated HRonset during the first few seconds of exercise (HRonsetshort), in which central command and the mechanoreflex determine vagal withdrawal, the major mechanism by which heart rate (HR) increases. In subsequent sports and rehabilitation studies, interest focused on HRonset during dynamic exercise over a longer period of time (HRonsetlong). Central command, mechanoreflexes, baroreflexes, and possibly metaboreflexes contribute to HRonset during the first seconds and minutes of exercise, which in turn leads to further vagal withdrawal and an increase in sympathetic activity. HRonset has been described as the increase in HR compared with resting state (delta HR) or by exponential modeling, with measurement intervals ranging from 0-4 s up to 2 min. Delta HR was used to evaluate HRonsetshort over the first 4 s of exercise, as well as for analyzing HRonsetlong. In exponential modeling, the HR response to dynamic exercise is biphasic, consisting of fast (parasympathetic, 0-10 s) and slow (sympathetic, 1-4 min) components. Although available studies differed largely in measurement protocols, cross-sectional and longitudinal training studies showed that studies analyzing HRonset

  11. Results of plasma N-terminal pro B-type natriuretic peptide and cardiac troponin monitoring in GIST patients do not support the existence of imatinib-induced cardiotoxicity

    NARCIS (Netherlands)

    Perik, P. J.; Rikhof, B.; de Jong, F. A.; Verweij, J.; Gietema, J. A.; van der Graaf, W. T. A.

    Background: Recently, case reports of patients treated with imatinib (imatinib mesylate; Gleevec (R); Glvec (R)) indicated that this tyrosine kinase inhibitor may induce cardiomyopathy. Consequently, careful cardiac monitoring was advocated for clinical studies. The purpose of this study was to

  12. Development of a Wearable Cardiac Monitoring System for Behavioral Neurocardiac Training: A Usability Study.

    Science.gov (United States)

    Uddin, Akib A; Morita, Plinio P; Tallevi, Kevin; Armour, Kevin; Li, John; Nolan, Robert P; Cafazzo, Joseph A

    2016-04-22

    Elevated blood pressure is one of the main risk factors for death globally. Behavioral neurocardiac training (BNT) is a complementary approach to blood pressure and stress management that is intended to exercise the autonomic reflexes, improve stress recovery, and lower blood pressure. BNT involves cognitive-behavioral therapy with a paced breathing technique and heart rate variability biofeedback. BNT is limited to in-clinic delivery and faces an accessibility barrier because of the need for clinical oversight and the use of complex monitoring tools. The objective of this project was to design, develop, and evaluate a wearable electrocardiographic (ECG) sensor system for the delivery of BNT in a home setting. The wearable sensor system, Beat, consists of an ECG sensor and a mobile app. It was developed iteratively using the principles of test-driven Agile development and user-centered design. A usability study was conducted at Toronto General Hospital to evaluate feasibility and user experience and identify areas of improvement. The Beat sensor was designed as a modular patch to be worn on the user's chest and uses standard ECG electrodes. It streams a single-lead ECG wirelessly to a mobile phone using Bluetooth Low Energy. The use of small, low-power electronics, a low device profile, and a tapered enclosure allowed for a device that can be unobtrusively worn under clothing. The sensor was designed to operate with a mobile app that guides users through the BNT exercises to train them to a slow-paced breathing technique for stress recovery. The BNT app uses the ECG captured by the sensor to provide heart rate variability biofeedback in the form of a real-time heart rate waveform to complement and reinforce the impact of the training. Usability testing (n=6) indicated that the overall response to the design and user experience of the system was perceived positively. All participants indicated that the system had a positive effect on stress management and that they

  13. Cardiac event monitors

    Science.gov (United States)

    ... From Cell to Bedside . 6th ed. Philadelphia, PA: Elsevier Saunders; 2014:chap 64. Maron BJ. Ventricular arrhythmias ... From Cell to Bedside . 6th ed. Philadelphia, PA: Elsevier Saunders; 2014:chap 86. Mathur N, Seutter R, ...

  14. Safety in cardiac surgery

    NARCIS (Netherlands)

    Siregar, S.

    2013-01-01

    The monitoring of safety in cardiac surgery is a complex process, which involves many clinical, practical, methodological and statistical issues. The objective of this thesis was to measure and to compare safety in cardiac surgery in The Netherlands using the Netherlands Association for

  15. Ventilation and gas exchange management after cardiac arrest.

    Science.gov (United States)

    Sutherasan, Yuda; Raimondo, Pasquale; Pelosi, Paolo

    2015-12-01

    For several decades, physicians had integrated several interventions aiming to improve the outcomes in post-cardiac arrest patients. However, the mortality rate after cardiac arrest is still as high as 50%. Post-cardiac arrest syndrome is associated with high morbidity and mortality due to not only poor neurological outcome and cardiovascular failure but also respiratory dysfunction. To minimize ventilator-associated lung injury, protective mechanical ventilation by using low tidal volume ventilation and driving pressure may decrease pulmonary complications and improve survival. Low level of positive end-expiratory pressure (PEEP) can be initiated and titrated with careful cardiac output and respiratory mechanics monitoring. Furthermore, optimizing gas exchange by avoiding hypoxia and hyperoxia as well as maintaining normocarbia may improve neurological and survival outcome. Early multidisciplinary cardiac rehabilitation intervention is recommended. Minimally invasive monitoring techniques, that is, echocardiography, transpulmonary thermodilution method measuring extravascular lung water, as well as transcranial Doppler ultrasound, might be useful to improve appropriate management of post-cardiac arrest patients. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. [Computer cardiokymography. On its way to long-term noninvasive monitoring of cardiac performance in daly life].

    Science.gov (United States)

    Khaiutin, V M; Lukoshkova, E V; Sheroziia, G G

    2004-05-01

    stop veloergometry at lower loads, thus increasing the safety of the test. Since for large medical insurance companies very simple and inexpensive cardiokymograph are quite unprofitable, their commercially production in USA and in Germany has been stopped. However, the goal of cardiokymography: a real-time, beat-to-beat, long-term monitoring of cardiac function in daily life, remains the major factor determining the future of the method.

  17. Implementation and reimbursement of remote monitoring for cardiac implantable electronic devices in Europe: a survey from the health economics committee of the European Heart Rhythm Association.

    Science.gov (United States)

    Mairesse, Georges H; Braunschweig, Frieder; Klersy, Katherine; Cowie, Martin R; Leyva, Francisco

    2015-05-01

    Remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) permits early detection of arrhythmias, device, and lead failure and may also be useful in risk-predicting patient-related outcomes. Financial benefits for patients and healthcare organizations have also been shown. We sought to assess the implementation and funding of RM of CIEDs, including conventional pacemakers (PMs), implantable cardioverter defibrillators (ICDs), and cardiac resynchronization therapy (CRT) devices in Europe. Electronic survey from 43 centres in 15 European countries. In the study sample, RM was available in 22% of PM patients, 74% of ICD patients, and 69% of CRT patients. The most significant perceived benefits were the early detection of atrial arrhythmias in pacemaker patients, lead failure in ICD patients, and worsening heart failure in CRT patients. Remote monitoring was reported to lead a reduction of in-office follow-ups for all devices. The most important reported barrier to the implementation of RM for all CIEDs was lack of reimbursement (80% of centres). Physicians regard RM of CIEDs as a clinically useful technology that affords significant benefits for patients and healthcare organizations. Remote monitoring, however, is perceived as increasing workload. Reimbursement for RM is generally perceived as a major barrier to implementation. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  18. Evaluation and optimisation of current milrinone prescribing for the treatment and prevention of low cardiac output syndrome in paediatric patients after open heart surgery using a physiology-based pharmacokinetic drug-disease model.

    Science.gov (United States)

    Vogt, Winnie

    2014-01-01

    Milrinone is the drug of choice for the treatment and prevention of low cardiac output syndrome (LCOS) in paediatric patients after open heart surgery across Europe. Discrepancies, however, among prescribing guidance, clinical studies and practice pattern require clarification to ensure safe and effective prescribing. However, the clearance prediction equations derived from classical pharmacokinetic modelling provide limited support as they have recently failed a clinical practice evaluation. Therefore, the objective of this study was to evaluate current milrinone dosing using physiology-based pharmacokinetic (PBPK) modelling and simulation to complement the existing pharmacokinetic knowledge and propose optimised dosing regimens as a basis for improving the standard of care for paediatric patients. A PBPK drug-disease model using a population approach was developed in three steps from healthy young adults to adult patients and paediatric patients with and without LCOS after open heart surgery. Pre- and postoperative organ function values from adult and paediatric patients were collected from literature and integrated into a disease model as factorial changes from the reference values in healthy adults aged 20-40 years. The disease model was combined with the PBPK drug model and evaluated against existing pharmacokinetic data. Model robustness was assessed by parametric sensitivity analysis. In the next step, virtual patient populations were created, each with 1,000 subjects reflecting the average adult and paediatric patient characteristics with regard to age, sex, bodyweight and height. They were integrated into the PBPK drug-disease model to evaluate the effectiveness of current milrinone dosing in achieving the therapeutic target range of 100-300 ng/mL milrinone in plasma. Optimised dosing regimens were subsequently developed. The pharmacokinetics of milrinone in healthy young adults as well as adult and paediatric patients were accurately described with an

  19. Applicability of a bioelectronic cardiac monitoring system for the detection of biological effects of pollution in bioindicator species in the Gulf of Finland

    Science.gov (United States)

    Kholodkevich, Sergey V.; Kuznetsova, Tatiana V.; Sharov, Andrey N.; Kurakin, Anton S.; Lips, Urmas; Kolesova, Natalia; Lehtonen, Kari K.

    2017-07-01

    Field testing of an innovative technology based on a bioelectronic cardiac monitoring system was carried out in the Gulf of Finland (Baltic Sea). The study shows that the bioelectronic system is suitable for the selected bivalve mollusks Mytilus trossulus, Macoma balthica and Anodonta anatina. Specimens taken from reference sites demonstrated a heart rate recovery time of freshwater and brackish water areas. Development of methodological basis for the testing of adaptive capacities (health) of key aquatic organisms provides new knowledge of biological effects of anthropogenic chemical stress in aquatic organisms.

  20. Clinical review: Update on hemodynamic monitoring - a consensus of 16.

    NARCIS (Netherlands)

    Vincent, J.L.; Rhodes, A.; Perel, A.; Martin, G.S.; Rocca, G.D.; Vallet, B.; Pinsky, M.R.; Hofer, C.K.; Teboul, J.L.; Boode, W.P. de; Scolletta, S.; Viellard-Baron, A.; Backer, D. de; Walley, K.R.; Maggiorini, M.; Singer, M.

    2011-01-01

    Hemodynamic monitoring plays a fundamental role in the management of acutely ill patients. With increased concerns about the use of invasive techniques, notably the pulmonary artery catheter, to measure cardiac output, recent years have seen an influx of new, less-invasive means of measuring

  1. Diabetes Mellitus, Microalbuminuria, and Subclinical Cardiac Disease: Identification and Monitoring of Individuals at Risk of Heart Failure.

    Science.gov (United States)

    Swoboda, Peter P; McDiarmid, Adam K; Erhayiem, Bara; Ripley, David P; Dobson, Laura E; Garg, Pankaj; Musa, Tarique A; Witte, Klaus K; Kearney, Mark T; Barth, Julian H; Ajjan, Ramzi; Greenwood, John P; Plein, Sven

    2017-07-17

    Patients with type 2 diabetes mellitus and elevated urinary albumin:creatinine ratio (ACR) have increased risk of heart failure. We hypothesized this was because of cardiac tissue changes rather than silent coronary artery disease. In a case-controlled observational study 130 subjects including 50 ACR+ve diabetes mellitus patients with persistent microalbuminuria (ACR >2.5 mg/mol in males and >3.5 mg/mol in females, ≥2 measurements, no previous renin-angiotensin-aldosterone therapy, 50 ACR-ve diabetes mellitus patients and 30 controls underwent cardiovascular magnetic resonance for investigation of myocardial fibrosis, ischemia and infarction, and echocardiography. Thirty ACR+ve patients underwent further testing after 1-year treatment with renin-angiotensin-aldosterone blockade. Cardiac extracellular volume fraction, a measure of diffuse fibrosis, was higher in diabetes mellitus patients than controls (26.1±3.4% and 23.3±3.0% P =0.0002) and in ACR+ve than ACR-ve diabetes mellitus patients (27.2±4.1% versus 25.1±2.9%, P =0.004). ACR+ve patients also had lower E' measured by echocardiography (8.2±1.9 cm/s versus 8.9±1.9 cm/s, P =0.04) and elevated high-sensitivity cardiac troponin T 18% versus 4% ≥14 ng/L ( P =0.05). Rate of silent myocardial ischemia or infarction were not influenced by ACR status. Renin-angiotensin-aldosterone blockade was associated with increased left ventricular ejection fraction (59.3±7.8 to 61.5±8.7%, P =0.03) and decreased extracellular volume fraction (26.5±3.6 to 25.2±3.1, P =0.01) but no changes in diastolic function or high-sensitivity cardiac troponin T levels. Asymptomatic diabetes mellitus patients with persistent microalbuminuria have markers of diffuse cardiac fibrosis including elevated extracellular volume fraction, high-sensitivity cardiac troponin T, and diastolic dysfunction, which may in part be reversible by renin-angiotensin-aldosterone blockade. Increased risk in these patients may be mediated by

  2. Prevalence of nursing diagnosis of decreased cardiac output and the predictive value of defining characteristics in patients under evaluation for heart transplant Prevalencia del diagnóstico de enfermería de disminución del gasto cardíaco y valor predictivo de las características definidoras en pacientes en fase de evaluación para trasplante cardíaco Prevalência do diagnóstico de enfermagem de débito cardíaco diminuído e valor preditivo das características definidoras em pacientes em avaliação para transplante cardíaco

    OpenAIRE

    Lígia Neres Matos; Tereza Cristina Felippe Guimarães; Marcos Antônio Gomes Brandão; Deyse Conceição Santoro

    2012-01-01

    The purposes of the study were to identify the prevalence of defining characteristics (DC) of decreased cardiac output (DCO) in patients with cardiac insufficiency under evaluation for heart transplantation, and to ascertain the likelihood of defining characteristics being predictive factors for the existence of reduction in cardiac output. Data was obtained by retrospective documental analysis of the clinical records of right-sided heart catheterizations in 38 patients between 2004 and 2009....

  3. Digitally enhanced recovery: Investigating the use of digital self-tracking for monitoring leisure time physical activity of cardiovascular disease (CVD patients undergoing cardiac rehabilitation.

    Directory of Open Access Journals (Sweden)

    Jürgen Vogel

    Full Text Available Research has shown that physical activity is essential in the prevention and treatment of chronic diseases like cardiovascular disease (CVD. Smart wearables (e.g., smartwatches are increasingly used to foster and monitor human behaviour, including physical activity. However, despite this increased usage, little evidence is available on the effects of smart wearables in behaviour change. The little research which is available typically focuses on the behaviour of healthy individuals rather than patients. In this study, we investigate the effects of using smart wearables by patients undergoing cardiac rehabilitation. A field experiment involving 29 patients was designed and participants were either assigned to the study group (N = 13 patients who finished the study and used a self-tracking device or the control group (N = 16 patients who finished the study and did not use a device. For both groups data about physiological performance during cardiac stress test was collected at the beginning (baseline, in the middle (in week 6, at the end of the rehabilitation in the organized rehabilitation setting, and at the end of the study (after 12 weeks, at the end of the rehabilitation, including the organized rehabilitation plus another 6 weeks of self-organized rehabilitation. Comparing the physiological performance of both groups, the data showed significant differences. The participants in the study group not only maintained the same performance level as during the midterm examination in week 6, they improved performance even further during the six weeks that followed. The results presented in this paper provide evidence for positive effects of digital self-tracking by patients undergoing cardiac rehabilitation on performance of the cardiovascular system. In this way, our study provides novel insight about the effects of the use of smart wearables by CVD patients. Our findings have implications for the design of self-management approaches in a patient

  4. Cerebral monitoring during neonatal surgery for non-cardiac congenital anomalies: a first step to improve outcome?

    NARCIS (Netherlands)

    Stolwijk, L.J.

    2017-01-01

    Monitoring the newborn brain during surgery Cerebral monitoring in newborns, who require surgery in the first month of life, is important to protect the brain. The newborn brain is vulnerable during neonatal surgery. Newborn babies with a congenital anomaly requiring surgery in the first month of

  5. Unit 16 - Output

    OpenAIRE

    Unit 16, CC in GIS; Star, Jeffrey L.

    1990-01-01

    This unit discusses issues related to GIS output, including the different types of output possible and the hardware for producing each. It describes text, graphic and digital data that can be generated by a GIS as well as line printers, dot matrix printers/plotters, pen plotters, optical scanners and cathode ray tubes (CRTs) as technologies for generating the output.

  6. External cardiac compression may be harmful in some scenarios of pulseless electrical activity.

    Science.gov (United States)

    Hogan, T S

    2012-10-01

    Pulseless electrical activity occurs when organised or semi-organised electrical activity of the heart persists but the product of systemic vascular resistance and the increase in systemic arterial flow generated by the ejection of the left venticular stroke volume is not sufficient to produce a clinically detectable pulse. Pulseless electrical activity encompasses a very heterogeneous variety of severe circulatory shock states ranging in severity from pseudo-cardiac arrest to effective cardiac arrest. Outcomes of cardiopulmonary resuscitation for pulseless electrical activity are generally poor. Impairment of cardiac filling is the limiting factor to cardiac output in many scenarios of pulseless electrical activity, including extreme vasodilatory shock states. There is no evidence that external cardiac compression can increase cardiac output when impaired cardiac filling is the limiting factor to cardiac output. If impaired cardiac filling is the limiting factor to cardiac output and the heart is effectively ejecting all the blood returning to it, then external cardiac compression can only increase cardiac output if it increases venous return and cardiac filling. Repeated cardiac compression asynchronous with the patient's cardiac cycle and raised mean intrathoracic pressure due to chest compression can be expected to reduce rather than to increase cardiac filling and therefore to reduce rather than to increase cardiac output in such circumstances. The hypothesis is proposed that the performance of external cardiac compression will have zero or negative effect on cardiac output in pulseless electrical activity when impaired cardiac filling is the limiting factor to cardiac output. External cardiac compression may be both directly and indirectly harmful to significant sub-groups of patients with pulseless electrical activity. We have neither evidence nor theory to provide comfort that external cardiac compression is not harmful in many scenarios of pulseless

  7. External cardiac compression may be harmful in some scenarios of pulseless electrical activity.

    LENUS (Irish Health Repository)

    Hogan, T S

    2012-10-01

    Pulseless electrical activity occurs when organised or semi-organised electrical activity of the heart persists but the product of systemic vascular resistance and the increase in systemic arterial flow generated by the ejection of the left venticular stroke volume is not sufficient to produce a clinically detectable pulse. Pulseless electrical activity encompasses a very heterogeneous variety of severe circulatory shock states ranging in severity from pseudo-cardiac arrest to effective cardiac arrest. Outcomes of cardiopulmonary resuscitation for pulseless electrical activity are generally poor. Impairment of cardiac filling is the limiting factor to cardiac output in many scenarios of pulseless electrical activity, including extreme vasodilatory shock states. There is no evidence that external cardiac compression can increase cardiac output when impaired cardiac filling is the limiting factor to cardiac output. If impaired cardiac filling is the limiting factor to cardiac output and the heart is effectively ejecting all the blood returning to it, then external cardiac compression can only increase cardiac output if it increases venous return and cardiac filling. Repeated cardiac compression asynchronous with the patient\\'s cardiac cycle and raised mean intrathoracic pressure due to chest compression can be expected to reduce rather than to increase cardiac filling and therefore to reduce rather than to increase cardiac output in such circumstances. The hypothesis is proposed that the performance of external cardiac compression will have zero or negative effect on cardiac output in pulseless electrical activity when impaired cardiac filling is the limiting factor to cardiac output. External cardiac compression may be both directly and indirectly harmful to significant sub-groups of patients with pulseless electrical activity. We have neither evidence nor theory to provide comfort that external cardiac compression is not harmful in many scenarios of pulseless

  8. Feasibility and Acceptability of Utilizing a Smartphone Based Application to Monitor Outpatient Discharge Instruction Compliance in Cardiac Disease Patients around Discharge from Hospitalization

    Directory of Open Access Journals (Sweden)

    Aimee M. Layton

    2014-01-01

    Full Text Available The purpose of this study was to determine the feasibility and acceptability of utilizing a smartphone based application to monitor compliance in patients with cardiac disease around discharge. For 60 days after discharge, patients’ medication compliance, physical activity, follow-up care, symptoms, and reading of education material were monitored daily with the application. 16 patients were enrolled in the study (12 males, 4 females, age 55 ± 18 years during their hospital stay. Five participants were rehospitalized during the study and did not use the application once discharged. Seven participants completed 1–30 days and four patients completed >31 days. For those 11 patients, medication reminders were utilized 37% (1–30-day group and 53% (>31-day group of the time, education material was read 44% (1–30 and 53% (>31 of the time, and physical activity was reported 25% (1–30 and 42% (>31 of the time. Findings demonstrated that patients with stable health utilized the application, even if only minimally. Patients with decreased breath sounds by physical exam and who reported their health as fair to poor on the day of discharge were less likely to utilize the application. Acceptability of the application to report health status varied among the stable patients.

  9. Validation of the concept Risk for Decreased Cardiac Output Validación del concepto riesgo de débito cardiaco disminuido Validação do conceito risco de débito cardíaco diminuído

    Directory of Open Access Journals (Sweden)

    Eduarda Ribeiro dos Santos

    2013-02-01

    Full Text Available OBJECTIVES: to validate the concept "risk for decreased cardiac output". METHOD: Six of the eight steps suggested in the technique developed by Walker & Avant were adopted to analyze the concept of the phenomenon under study and the proposal made by Hoskins was used for content validation, taking into account agreement achieved among five experts. RESULTS: the concept "decreased cardiac output" was found in the nursing and medical fields and refers to the heart's pumping capacity while the concept "risk" is found in a large number of disciplines. In regard to the defining attributes, "impaired pumping capacity" was the main attribute of decreased cardiac output and "probability" was the main attribute of risk. The uses and defining attributes of the concepts "decreased cardiac output" and "risk" were analyzed as well as their antecedent and consequent events in order to establish the definition of "risk for decreased cardiac output", which was validated by 100% of the experts. CONCLUSION: The obtained data indicate that the risk for decreased cardiac output phenomenon can be a nursing diagnosis and refining it can contribute to the advancement of nursing classifications in this context.OBJETIVO: Validar el concepto riesgo del débito cardíaco disminuido. MÉTODO: Fue adoptada la técnica de Walker & Avant para analizar la definición del fenómeno enfocado, utilizando seis de las ocho etapas sugeridas y la propuesta de Hoskins para validar el contenido, considerándose la conformidad entre cinco expertos. RESULTADOS: el concepto de debito cardíaco disminuido se encuentra en las áreas enfermería y médica y su atención se centra en la capacidad de bombeo del corazón. Sin embargo, el concepto de riesgo es presente en un gran número de áreas. Las características definitorias de la disminución del gasto cardíaco mostraron como principal atributo deficiencia de la bomba cardiaca y, para el riesgo, el atributo de probabilidad. Analizados

  10. Cardiac rehabilitation

    Science.gov (United States)

    ... rehab; Heart failure - cardiac rehab References Anderson L, Taylor RS. Cardiac rehabilitation for people with heart disease: ... of Medicine, Division of Cardiology, Harborview Medical Center, University of Washington Medical School, Seattle, WA. Also reviewed ...

  11. Sokolow-Lyon voltage is suitable for monitoring improvement in cardiac function and prognosis of patients with idiopathic dilated cardiomyopathy.

    Science.gov (United States)

    Fukaya, Kenji; Takeshita, Kyosuke; Okumura, Takahiro; Hiraiwa, Hiroaki; Aoki, Soichiro; Ichii, Takeo; Sugiura, Yuki; Kitagawa, Katsuhide; Kondo, Toru; Watanabe, Naoki; Kano, Naoaki; Furusawa, Kenji; Sawamura, Akinori; Morimoto, Ryota; Bando, Yasuko; Murohara, Toyoaki

    2017-09-01

    The clinical significance of electrocardiogram in the assessment of patients with idiopathic dilated cardiomyopathy (IDCM) is currently unknown. The aim of this study was to determine the feasibility of recording serial changes in Sokolow-Lyon voltage (∆%QRS-voltage) in one year to estimate left ventricular reverse remodeling (LVRR) and predict a prognosis of IDCM patients under tailored medical therapy. Sixty-eight consecutive patients with mild symptoms (52.1 ± 13 years old; 69% men; NYHA I/II/III/IV; 33/29/6/0) underwent electrocardiography and echocardiography at baseline and 12 month follow-up (follow-up period: 3.9 years). LVRR was observed in 30 patients (44.1%). The ∆%QRS-voltage was significantly lower in the LVRR group (LVRR; -26.9%, non-LVRR: -9.2%, p voltage correlated with ∆%LV end-diastolic diameter (r = .634, p voltage group (voltage is associated with improvement in cardiac function and favorable prognosis in IDCM patients on medical therapy, suggesting that this index is a feasible marker for response to treatment of IDCM. © 2017 Wiley Periodicals, Inc.

  12. Pediatric cardiac postoperative care

    Directory of Open Access Journals (Sweden)

    Auler Jr. José Otávio Costa

    2002-01-01

    Full Text Available The Heart Institute of the University of São Paulo, Medical School is a referral center for the treatment of congenital heart diseases of neonates and infants. In the recent years, the excellent surgical results obtained in our institution may be in part due to modern anesthetic care and to postoperative care based on well-structured protocols. The purpose of this article is to review unique aspects of neonate cardiovascular physiology, the impact of extracorporeal circulation on postoperative evolution, and the prescription for pharmacological support of acute cardiac dysfunction based on our cardiac unit protocols. The main causes of low cardiac output after surgical correction of heart congenital disease are reviewed, and methods of treatment and support are proposed as derived from the relevant literature and our protocols.

  13. A low-power and miniaturized electrocardiograph data collection system with smart textile electrodes for monitoring of cardiac function.

    Science.gov (United States)

    Dai, Ming; Xiao, Xueliang; Chen, Xin; Lin, Haoming; Wu, Wanqing; Chen, Siping

    2016-12-01

    With the increasing aging population as well as health concerns, chronic heart disease has become the focus of public attention. A comfortable, low-powered, and wearable electrocardiogram (ECG) system for continuously monitoring the elderly's ECG signals over several hours is important for preventing cardiovascular diseases. Traditional ECG monitoring apparatus is often inconvenient to carry, has many electrodes to attach to the chest, and has a high-power consumption. There is also a challenge to design an electrocardiograph that satisfies requirements such as comfort, confinement, and compactness. Based on these considerations, this study presents a biosensor acquisition system for wearable, ubiquitous healthcare applications using three textile electrodes and a recording circuit specialized for ECG monitoring. In addition, several methods were adopted to reduce the power consumption of the device. The proposed system is composed of three parts: (1) an ECG analog front end (AFE), (2) digital signal processing and micro-control circuits, and (3) system software. Digital filter methods were used to eliminate the baseline wander, skin contact noise, and other interfering signals. A comparative study was conducted using this system to observe its performance with two commercial Holter monitors. The experimental results demonstrated that the total power consumption of this proposed system in a full round of ECG acquisition was only 29.74 mW. In addition, this low-power system performed well and stably measured the heart rate with an accuracy of 98.55 %. It can also contain a real-time dynamic display with organic light-emitting diodes (OLED) and wirelessly transmit information via a Bluetooth 4.0 module.

  14. The effects of malnutrition on cardiac function in African children.

    Science.gov (United States)

    Silverman, Jonathan A; Chimalizeni, Yamikani; Hawes, Stephen E; Wolf, Elizabeth R; Batra, Maneesh; Khofi, Harriet; Molyneux, Elizabeth M

    2016-02-01

    Cardiac dysfunction may contribute to high mortality in severely malnourished children. Our objective was to assess the effect of malnutrition on cardiac function in hospitalised African children. Prospective cross-sectional study. Public referral hospital in Blantyre, Malawi. We enrolled 272 stable, hospitalised children ages 6-59 months, with and without WHO-defined severe acute malnutrition. Cardiac index, heart rate, mean arterial pressure, stroke volume index and systemic vascular resistance index were measured by the ultrasound cardiac output monitor (USCOM, New South Wales, Australia). We used linear regression with generalised estimating equations controlling for age, sex and anaemia. Our primary outcome, cardiac index, was similar between those with and without severe malnutrition: difference=0.22 L/min/m(2) (95% CI -0.08 to 0.51). No difference was found in heart rate or stroke volume index. However, mean arterial pressure and systemic vascular resistance index were lower in children with severe malnutrition: difference=-8.6 mm Hg (95% CI -12.7 to -4.6) and difference=-200 dyne s/cm(5)/m(2) (95% CI -320 to -80), respectively. In this largest study to date, we found no significant difference in cardiac function between hospitalised children with and without severe acute malnutrition. Further study is needed to determine if cardiac function is diminished in unstable malnourished children. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  15. Output hardcopy devices

    CERN Document Server

    Durbeck, Robert

    1988-01-01

    Output Hardcopy Devices provides a technical summary of computer output hardcopy devices such as plotters, computer output printers, and CRT generated hardcopy. Important related technical areas such as papers, ribbons and inks, color techniques, controllers, and character fonts are also covered. Emphasis is on techniques primarily associated with printing, as well as the plotting capabilities of printing devices that can be effectively used for computer graphics in addition to their various printing functions. Comprised of 19 chapters, this volume begins with an introduction to vector and ras

  16. ?Healthcare IoT m-GreenCARDIO Remote Cardiac Monitoring System - Concept, Theory of Operation and Implementation

    Directory of Open Access Journals (Sweden)

    ZAGAN, I.

    2017-05-01

    Full Text Available Present day Internet of Things (IoT developers are inspired by the spectacular evolution in the field, and, at the same time, determined to connect an increasingly wider range of 'things', with the lowest power consumption, the wider range of action and interoperability guaranteed with excessive quality. Based on current challenges in the medical and electronic field, the present paper seeks the practical implementation of an efficient, low cost, low-power IoT medical system, yet with a greater memory autonomy. In this context, our main contribution is the implementation of a solution for ECG monitoring based on IoT techniques. This paper presents a qualitative research in the field of healthcare IoT and embedded applications meant to provide an innovative and flexible system meeting the stringent requirements of this area. Without compromising the performance intake and the low power consumption, the designers offer flexible options for connectivity and response time.

  17. A bioelectronic system for the monitoring of cardiac activity in mussels and crabs and its application in environmental assessments

    DEFF Research Database (Denmark)

    Kholodkevich, Sergey V.; Kuznetsova, Tatiana; Lehtonen, Kari

    , SRCES RAS has carried out studies contributing to ecosystem health assessment basing on evaluation of the physiological state of organisms by the means of noninvasive fiber-optic monitoring of heartbeat of selected invertebrate species (Mytilus edulis, Macoma balthica, Carcinus maenas). During the 2...... years of the project the SRCES activities were focused to test organisms in the field in different sub-regions of the Baltic Sea, including measurements on board of research vessels and in the laboratory. The data obtained have led to the improved characterization of cardio-vascular system responses...... in mollusks and crabs under standard test stimuli and the development of new biomarkers based on heart rate of aquatic invertebrates. Responses to treatments with standard test stimuli provide integral information of the adaptive capacities of organisms. The results of these studies demonstratedsignificant...

  18. Cost Effectiveness of Implantable Cardiac Monitor-Guided Intermittent Anticoagulation for Atrial Fibrillation: An Analysis of the REACT.COM Pilot Study.

    Science.gov (United States)

    Steinhaus, Daniel A; Zimetbaum, Peter J; Passman, Rod S; Leong-Sit, Peter; Reynolds, Matthew R

    2016-08-30

    Anticoagulation guidelines for patients with atrial fibrillation (AF) disregard AF burden. A strategy of targeted anticoagulation with novel oral anticoagulants (NOACs) based on continuous rhythm assessment with an implantable cardiac monitor (ICM) has recently been explored. We evaluated the potential cost-effectiveness of this strategy versus projected outcomes with continuous anticoagulation. We developed a Markov model using data from the Rhythm Evaluation for AntiCoagulaTion With COntinuous Monitoring (REACT.COM) pilot study (N = 59) and prior NOAC trials to calculate the costs and quality-adjusted life years (QALYs) associated with ICM-guided intermittent anticoagulation for AF versus standard care during a 3-year time horizon. Health state utilities were estimated from the pilot study population using the SF-12. Costs were based on current Medicare reimbursement. Over 14 ± 4 months of follow-up, 18 of 59 patients had 35 AF episodes. The ICM-guided strategy resulted in a 94% reduction in anticoagulant use relative to continuous treatment. There were no strokes, 3 (5.1%) TIAs, 2 major bleeding events (on aspirin) and 3 minor bleeding events with the ICM-guided strategy. The projected total 3-year costs were $12,535 for the ICM-guided strategy versus $13,340 for continuous anticoagulation. Projected QALYs were 2.45 for both groups. Based on a pilot study, a strategy of ICM-guided anticoagulation with NOACs may be cost-saving relative to expected outcomes with continuous anticoagulation, with similar quality-adjusted survival. This strategy could be attractive from a health economic perspective if shown to be safe and effective in a rigorous clinical trial. © 2016 Wiley Periodicals, Inc.

  19. WRF Model Output

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset contains WRF model output. There are three months of data: July 2012, July 2013, and January 2013. For each month, several simulations were made: A...

  20. VMS forms Output Tables

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These output tables contain parsed and format validated data from the various VMS forms that are sent from any given vessel, while at sea, from the VMS devices on...

  1. Governmentally amplified output volatility

    Science.gov (United States)

    Funashima, Yoshito

    2016-11-01

    Predominant government behavior is decomposed by frequency into several periodic components: updating cycles of infrastructure, Kuznets cycles, fiscal policy over business cycles, and election cycles. Little is known, however, about the theoretical impact of such cyclical behavior in public finance on output fluctuations. Based on a standard neoclassical growth model, this study intends to examine the frequency at which public investment cycles are relevant to output fluctuations. We find an inverted U-shaped relationship between output volatility and length of cycle in public investment. This implies that periodic behavior in public investment at a certain frequency range can cause aggravated output resonance. Moreover, we present an empirical analysis to test the theoretical implication, using the U.S. data in the period from 1968 to 2015. The empirical results suggest that such resonance phenomena change from low to high frequency.

  2. CMAQ Model Output

    Data.gov (United States)

    U.S. Environmental Protection Agency — CMAQ and CMAQ-VBS model output. This dataset is not publicly accessible because: Files too large. It can be accessed through the following means: via EPA's NCC tape...

  3. Technology-Enabled Remote Monitoring and Self-Management - Vision for Patient Empowerment Following Cardiac and Vascular Surgery: User Testing and Randomized Controlled Trial Protocol.

    Science.gov (United States)

    McGillion, Michael; Yost, Jennifer; Turner, Andrew; Bender, Duane; Scott, Ted; Carroll, Sandra; Ritvo, Paul; Peter, Elizabeth; Lamy, Andre; Furze, Gill; Krull, Kirsten; Dunlop, Valerie; Good, Amber; Dvirnik, Nazari; Bedini, Debbie; Naus, Frank; Pettit, Shirley; Henry, Shaunattonie; Probst, Christine; Mills, Joseph; Gossage, Elaine; Travale, Irene; Duquette, Janine; Taberner, Christy; Bhavnani, Sanjeev; Khan, James S; Cowan, David; Romeril, Eric; Lee, John; Colella, Tracey; Choinière, Manon; Busse, Jason; Katz, Joel; Victor, J Charles; Hoch, Jeffrey; Isaranuwatchai, Wanrudee; Kaasalainen, Sharon; Ladak, Salima; O'Keefe-McCarthy, Sheila; Parry, Monica; Sessler, Daniel I; Stacey, Michael; Stevens, Bonnie; Stremler, Robyn; Thabane, Lehana; Watt-Watson, Judy; Whitlock, Richard; MacDermid, Joy C; Leegaard, Marit; McKelvie, Robert; Hillmer, Michael; Cooper, Lynn; Arthur, Gavin; Sider, Krista; Oliver, Susan; Boyajian, Karen; Farrow, Mark; Lawton, Chris; Gamble, Darryl; Walsh, Jake; Field, Mark; LeFort, Sandra; Clyne, Wendy; Ricupero, Maria; Poole, Laurie; Russell-Wood, Karsten; Weber, Michael; McNeil, Jolene; Alpert, Robyn; Sharpe, Sarah; Bhella, Sue; Mohajer, David; Ponnambalam, Sem; Lakhani, Naeem; Khan, Rabia; Liu, Peter; Devereaux, P J

    2016-08-01

    Tens of thousands of cardiac and vascular surgeries (CaVS) are performed on seniors in Canada and the United Kingdom each year to improve survival, relieve disease symptoms, and improve health-related quality of life (HRQL). However, chronic postsurgical pain (CPSP), undetected or delayed detection of hemodynamic compromise, complications, and related poor functional status are major problems for substantial numbers of patients during the recovery process. To tackle this problem, we aim to refine and test the effectiveness of an eHealth-enabled service delivery intervention, TecHnology-Enabled remote monitoring and Self-MAnagemenT-VIsion for patient EmpoWerment following Cardiac and VasculaR surgery (THE SMArTVIEW, CoVeRed), which combines remote monitoring, education, and self-management training to optimize recovery outcomes and experience of seniors undergoing CaVS in Canada and the United Kingdom. Our objectives are to (1) refine SMArTVIEW via high-fidelity user testing and (2) examine the effectiveness of SMArTVIEW via a randomized controlled trial (RCT). CaVS patients and clinicians will engage in two cycles of focus groups and usability testing at each site; feedback will be elicited about expectations and experience of SMArTVIEW, in context. The data will be used to refine the SMArTVIEW eHealth delivery program. Upon transfer to the surgical ward (ie, post-intensive care unit [ICU]), 256 CaVS patients will be reassessed postoperatively and randomly allocated via an interactive Web randomization system to the intervention group or usual care. The SMArTVIEW intervention will run from surgical ward day 2 until 8 weeks following surgery. Outcome assessments will occur on postoperative day 30; at week 8; and at 3, 6, 9, and 12 months. The primary outcome is worst postop pain intensity upon movement in the previous 24 hours (Brief Pain Inventory-Short Form), averaged across the previous 14 days. Secondary outcomes include a composite of postoperative

  4. Oil output's changing fortunes

    International Nuclear Information System (INIS)

    Eldridge, D.

    1994-01-01

    The Petroleum Economist, previously the Petroleum Press Service, has been making annual surveys of output levels of petroleum in all the oil-producing countries since its founding in 1934. This article documents trends and changes in the major oil-producing countries output from 1934 until the present. This analysis is linked with the political and historical events accompanying these changes, notably the growth of Middle Eastern oil production, the North Sea finds and most recently, Iraq's invasion of Kuwait in 1990. (UK)

  5. Toll-Like Receptor 9 Promotes Cardiac Inflammation and Heart Failure during Polymicrobial Sepsis

    Directory of Open Access Journals (Sweden)

    Ralph Lohner

    2013-01-01

    Full Text Available Background. Aim was to elucidate the role of toll-like receptor 9 (TLR9 in cardiac inflammation and septic heart failure in a murine model of polymicrobial sepsis. Methods. Sepsis was induced via colon ascendens stent peritonitis (CASP in C57BL/6 wild-type (WT and TLR9-deficient (TLR9-D mice. Bacterial load in the peritoneal cavity and cardiac expression of inflammatory mediators were determined at 6, 12, 18, 24, and 36 h. Eighteen hours after CASP cardiac function was monitored in vivo. Sarcomere length of isolated cardiomyocytes was measured at 0.5 to 10 Hz after incubation with heat-inactivated bacteria. Results. CASP led to continuous release of bacteria into the peritoneal cavity, an increase of cytokines, and differential regulation of receptors of innate immunity in the heart. Eighteen hours after CASP WT mice developed septic heart failure characterised by reduction of end-systolic pressure, stroke volume, cardiac output, and parameters of contractility. This coincided with reduced cardiomyocyte sarcomere shortening. TLR9 deficiency resulted in significant reduction of cardiac inflammation and a sustained heart function. This was consistent with reduced mortality in TLR9-D compared to WT mice. Conclusions. In polymicrobial sepsis TLR9 signalling is pivotal to cardiac inflammation and septic heart failure.

  6. Cardiac function studies

    International Nuclear Information System (INIS)

    Horn, H.J.

    1986-01-01

    A total of 27 patients were subjected tointramyocardial sequential scintiscanning (first pass) using 99m-Tc human serum albumin. A refined method is described that is suitable to analyse clinically relevant parameters like blood volume, cardiac output, ejection fraction, stroke volume, enddiastolic and endsystolic volumes as well as pulmonal transition time and uses a complete camaracomputer system adapted to the requirements of a routine procedure. Unless there is special hardware available, the method does not yet appear mature enough to be put into general practice. Its importance recently appeared in a new light due to the advent of particularly shortlived isotopes. For the time being, however, ECG-triggered equilibrium studies are to be preferred for cardiac function tests. (TRV) [de

  7. The Association Between Urine Output, Creatinine Elevation, and Death.

    Science.gov (United States)

    Engoren, Milo; Maile, Michael D; Heung, Michael; Jewell, Elizabeth S; Vahabzadeh, Christie; Haft, Jonathan W; Kheterpal, Sachin

    2017-04-01

    Acute kidney injury can be defined by a fall in urine output, and urine output criteria may be more sensitive in identifying acute kidney injury than traditional serum creatinine criteria. However, as pointed out in the Kidney Disease Improving Global Outcome guidelines, the association of urine output with subsequent creatinine elevations and death is poorly characterized. The purpose of this study was to determine what degrees of reduced urine output are associated with subsequent creatinine elevation and death. This was a retrospective cohort study of adult patients (age ≥18 years) cared for in a cardiovascular intensive care unit after undergoing cardiac operations in a tertiary care university medical center. All adult patients who underwent cardiac operations and were not receiving dialysis preoperatively were studied. The development of acute kidney injury was defined as an increase in creatinine of more than 0.3 mg/dL or by more than 50% above baseline by postoperative day 3. Acute kidney injury developed in 1,061 of 4,195 patients (25%). Urine output had moderate discrimination in predicting subsequent acute kidney injury (C statistic = .637 ± .054). Lower urine output and longer duration of low urine output were associated with greater odds of developing acute kidney injury and death. We found that there is similar accuracy in using urine output corrected for actual, ideal, or adjusted weight to discriminate future acute kidney injury by creatinine elevation and recommend using actual weight for its simplicity. We also found that low urine output is associated with subsequent acute kidney injury and that the association is greater for lower urine output and for low urine output of longer durations. Low urine output (creatinine elevation, is independently associated with mortality. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Cardiac arrest

    Science.gov (United States)

    ... magnesium. These minerals help your heart's electrical system work. Abnormally high or low levels can cause cardiac arrest. Severe physical stress. Anything that causes a severe stress on your ...

  9. Cardiac Ochronosis

    Science.gov (United States)

    Erek, Ersin; Casselman, Filip P.A.; Vanermen, Hugo

    2004-01-01

    We report the case of 67-year-old woman who underwent aortic valve replacement and mitral valve repair due to ochronotic valvular disease (alkaptonuria), which was diagnosed incidentally during cardiac surgery. PMID:15745303

  10. Cardiac catheterization

    Science.gov (United States)

    ... tests. However, it is very safe when done by an experienced team. The risks include: Cardiac tamponade Heart attack Injury to a coronary artery Irregular heartbeat Low blood pressure Reaction to the contrast dye Stroke Possible complications ...

  11. Nuclear cardiac

    International Nuclear Information System (INIS)

    Slutsky, R.; Ashburn, W.L.

    1982-01-01

    The relationship between nuclear medicine and cardiology has continued to produce a surfeit of interesting, illuminating, and important reports involving the analysis of cardiac function, perfusion, and metabolism. To simplify the presentation, this review is broken down into three major subheadings: analysis of myocardial perfusion; imaging of the recent myocardial infarction; and the evaluation of myocardial function. There appears to be an increasingly important relationship between cardiology, particularly cardiac physiology, and nuclear imaging techniques

  12. Cardiac output and vasodilation in the vasovagal response

    DEFF Research Database (Denmark)

    Wieling, Wouter; Jardine, David L.; de Lange, Frederik J

    2016-01-01

    . Plethysmographic measurements were intermittent and not frequent enough to capture rapid changes in blood flow during progressive hypotension. However, later investigations by Weissler, Murray, and Stevens performed between 1950 and 1970 used invasive beat-to-beat BP measurements and more frequent measurements...

  13. Effects of Exercise Training on Haematology and Maximal Cardiac Output

    DEFF Research Database (Denmark)

    Bonne, Thomas Christian

    = 0.051) and time to complete 3000 m tended (P = 0.09) to increase in LHTH but not after sea level training. In study III haematological parameters were determined weekly three times before and four times after classical altitude and sea level training and ABP thresholds for [Hb], %ret, OFF......-score and the abnormal blood profile score (ABPS) were generated using the official ABP software. After altitude training, six swimmers exceeded the 99% ABP thresholds: Two swimmers exceeded the OFF-score thresholds at day 7; One swimmer exceeded the OFF-score threshold at day 28; One swimmer exceeded the threshold...... for %ret at day 14; One swimmer surpassed the ABPS threshold at day 7 and one swimmer exceeded the ABPS threshold 28 days after altitude training. No values exceeded the individual thresholds in the control group. In conclusion, this thesis demonstrated that BV is a main determinant of the exercise induced...

  14. Relationship between cardiac function and resting cerebral blood flow

    DEFF Research Database (Denmark)

    Henriksen, Otto M; Jensen, Lars T; Krabbe, Katja

    2014-01-01

    ) and 2.4 l min(-1) m(-2), respectively, in females. No effects of cardiac output or cardiac index on CBF or structural signs of brain ageing were observed. However, fractional brain flow defined as the ratio of total brain flow to cardiac output was inversely correlated with cardiac index (r(2) = 0.22, P...... = 0.008) and furthermore lower in males than in females (8.6% versus 12.5%, P = 0.003). Fractional brain flow was also inversely correlated with cerebral white matter lesion grade, although this effect was not significant when adjusted for age. Frequency analysis of heart rate variability showed...

  15. Metoclopramide-induced cardiac arrest

    Directory of Open Access Journals (Sweden)

    Martha M. Rumore

    2011-11-01

    Full Text Available The authors report a case of cardiac arrest in a patient receiving intravenous (IV metoclopramide and review the pertinent literature. A 62-year-old morbidly obese female admitted for a gastric sleeve procedure, developed cardiac arrest within one minute of receiving metoclopramide 10 mg via slow intravenous (IV injection. Bradycardia at 4 beats/min immediately appeared, progressing rapidly to asystole. Chest compressions restored vital function. Electrocardiogram (ECG revealed ST depression indicative of myocardial injury. Following intubation, the patient was transferred to the intensive care unit. Various cardiac dysrrhythmias including supraventricular tachycardia (SVT associated with hypertension and atrial fibrillation occurred. Following IV esmolol and metoprolol, the patient reverted to normal sinus rhythm. Repeat ECGs revealed ST depression resolution without pre-admission changes. Metoclopramide is a non-specific dopamine receptor antagonist. Seven cases of cardiac arrest and one of sinus arrest with metoclopramide were found in the literature. The metoclopramide prescribing information does not list precautions or adverse drug reactions (ADRs related to cardiac arrest. The reaction is not dose related but may relate to the IV administration route. Coronary artery disease was the sole risk factor identified. According to Naranjo, the association was possible. Other reports of cardiac arrest, severe bradycardia, and SVT were reviewed. In one case, five separate IV doses of 10 mg metoclopramide were immediately followed by asystole repeatedly. The mechanism(s underlying metoclopramide’s cardiac arrest-inducing effects is unknown. Structural similarities to procainamide may play a role. In view of eight previous cases of cardiac arrest from metoclopramide having been reported, further elucidation of this ADR and patient monitoring is needed. Our report should alert clinicians to monitor patients and remain diligent in surveillance and

  16. Endothelial Function as a Possible Significant Determinant of Cardiac Function during Exercise in Patients with Structural Heart Disease

    Directory of Open Access Journals (Sweden)

    Bonpei Takase

    2009-01-01

    Full Text Available This study was investigated the role that endothelial function and systemic vascular resistance (SVR play in determining cardiac function reserve during exercise by a new ambulatory radionuclide monitoring system (VEST in patients with heart disease. The study population consisted of 32 patients. The patients had cardiopulmonary stress testing using the treadmill Ramp protocol and the VEST. The anaerobic threshold (AT was autodetermined using the V-slope method. The SVR was calculated by determining the mean blood pressure/cardiac output. Flow-mediated vasodilation (FMD was measured in the brachial artery to evaluate endotheilial function. FMD and the percent change f'rom rest to AT in SVR correlated with those from rest to AT in ejection fraction and peak ejection ratio by VEST, respectively. Our findings suggest that FMD in the brachial artery and the SVR determined by VEST in patients with heart disease can possibly reflect cardiac function reserve during aerobic exercise.

  17. Cardiac CT

    International Nuclear Information System (INIS)

    Dewey, Marc

    2011-01-01

    Computed tomography of the heart has become a highly accurate diagnostic modality that is attracting increasing attention. This extensively illustrated book aims to assist the reader in integrating cardiac CT into daily clinical practice, while also reviewing its current technical status and applications. Clear guidance is provided on the performance and interpretation of imaging using the latest technology, which offers greater coverage, better spatial resolution, and faster imaging. The specific features of scanners from all four main vendors, including those that have only recently become available, are presented. Among the wide range of applications and issues to be discussed are coronary artery bypass grafts, stents, plaques, and anomalies, cardiac valves, congenital and acquired heart disease, and radiation exposure. Upcoming clinical uses of cardiac CT, such as plaque imaging and functional assessment, are also explored. (orig.)

  18. Cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc [Charite - Universitaetsmedizin Berlin (Germany). Inst. fuer Radiologie

    2011-07-01

    Computed tomography of the heart has become a highly accurate diagnostic modality that is attracting increasing attention. This extensively illustrated book aims to assist the reader in integrating cardiac CT into daily clinical practice, while also reviewing its current technical status and applications. Clear guidance is provided on the performance and interpretation of imaging using the latest technology, which offers greater coverage, better spatial resolution, and faster imaging. The specific features of scanners from all four main vendors, including those that have only recently become available, are presented. Among the wide range of applications and issues to be discussed are coronary artery bypass grafts, stents, plaques, and anomalies, cardiac valves, congenital and acquired heart disease, and radiation exposure. Upcoming clinical uses of cardiac CT, such as plaque imaging and functional assessment, are also explored. (orig.)

  19. Cardiac echinococcosis

    Directory of Open Access Journals (Sweden)

    Ivanović-Krstić Branislava A.

    2002-01-01

    Full Text Available Cardiac hydatid disease is rare. We report on an uncommon hydatid cyst localized in the right ventricular wall, right atrial wall tricuspid valve left atrium and pericard. A 33-year-old woman was treated for cough, fever and chest pain. Cardiac echocardiograpic examination revealed a round tumor (5.8 x 4 cm in the right ventricular free wall and two smaller cysts behind that tumor. There were cysts in right atrial wall and tricuspidal valve as well. Serologic tests for hydatidosis were positive. Computed tomography finding was consistent with diagnosis of hydatid cyst in lungs and right hylar part. Surgical treatment was rejected due to great risk of cardiac perforation. Medical treatment with albendazole was unsuccessful and the patient died due to systemic hydatid involvement of the lungs, liver and central nervous system.

  20. Milrinone ameliorates cardiac mechanical dysfunction after hypothermia in an intact rat model.

    Science.gov (United States)

    Dietrichs, Erik Sveberg; Kondratiev, Timofei; Tveita, Torkjel

    2014-12-01

    Rewarming from hypothermia is often complicated by cardiac dysfunction, characterized by substantial reduction in stroke volume. Previously we have reported that inotropic agents, working via cardiac β-receptor agonism may exert serious side effects when applied to treat cardiac contractile dysfunction during rewarming. In this study we tested whether Milrinone, a phosphodiesterase III inhibitor, is able to ameliorate such dysfunction when given during rewarming. A rat model designed for circulatory studies during experimental hypothermia with cooling to a core temperature of 15°C, stable hypothermia at this temperature for 3h and subsequent rewarming was used, with a total of 3 groups: (1) a normothermic group receiving Milrinone, (2) a hypothermic group receiving Milrinone the last hour of hypothermia and during rewarming, and (3) a hypothermic saline control group. Hemodynamic function was monitored using a conductance catheter introduced to the left ventricle. After rewarming from 15°C, stroke volume and cardiac output returned to within baseline values in Milrinone treated animals, while these variables were significantly reduced in saline controls. Milrinone ameliorated cardiac dysfunction during rewarming from 15°C. The present results suggest that at low core temperatures and during rewarming from such temperatures, pharmacologic efforts to support cardiovascular function is better achieved by substances preventing cyclic AMP breakdown rather than increasing its formation via β-receptor stimulation. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Intraoperative hemodynamic monitoring during liver transplantation: goals and devices

    DEFF Research Database (Denmark)

    Nissen, Peter; Frederiksen, H J; Secher, N H

    2010-01-01

    With the introduction of orthotopic liver transplantation (OLT) almost 40 years ago, changes in the cardiovascular system that manifest during the different phases of the operation combined, sometimes with massive hemorrhage in likely critically ill patients have been a challenge. Here hemodynamic...... monitoring of the patients during OLT is addressed with focus on maintaining the patients' central blood volume (CBV) and methods and devices that can serve that purpose are listed. It is considered that a stable CBV maintains cerebral blood flow and oxygenation and thereby the well-being of the patient......, while even a small reduction in blood pressure affects cerebral blood flow and oxygenation if it reflects a reduced CBV and thereby cardiac output. In that regard it is accepted that for the patient going through OLT cardiac output (~8 L/min-1) and also venous oxygen saturation (~85%) are larger than...

  2. Advanced hemodynamic monitoring in intensive care medicine : A German web-based survey study.

    Science.gov (United States)

    Saugel, B; Reese, P C; Wagner, J Y; Buerke, M; Huber, W; Kluge, S; Prondzinsky, R

    2018-04-01

    Advanced hemodynamic monitoring is recommended in patients with complex circulatory shock. To evaluate the current attitudes and beliefs among German intensivists, regarding advanced hemodynamic monitoring, the actual hemodynamic management in clinical practice, and the barriers to using it. Web-based survey among members of the German Society of Medical Intensive Care and Emergency Medicine. Of 284 respondents, 249 (87%) agreed that further hemodynamic assessment is needed to determine the type of circulatory shock if no clear clinical diagnosis can be made. In all, 281 (99%) agreed that echocardiography is helpful for this purpose (transpulmonary thermodilution: 225 [79%]; pulmonary artery catheterization: 126 [45%]). More than 70% of respondents agreed that blood flow variables (cardiac output, stroke volume) should be measured in patients with hemodynamic instability. The parameters most respondents agreed should be assessed in a patient with hemodynamic instability were mean arterial pressure, cardiac output, and serum lactate. Echocardiography is available in 99% of ICUs (transpulmonary thermodilution: 91%; pulmonary artery catheter: 63%). The respondents stated that, in clinical practice, invasive arterial pressure measurements and serum lactate measurements are performed in more than 90% of patients with hemodynamic instability (cardiac output monitoring in about 50%; transpulmonary thermodilution in about 40%). The respondents did not feel strong barriers to the use of advanced hemodynamic monitoring in clinical practice. This survey study shows that German intensivists deem advanced hemodynamic assessment necessary for the differential diagnosis of circulatory shock and to guide therapy with fluids, vasopressors, and inotropes in ICU patients.

  3. Trends in Cardiac Pacemaker Batteries

    Directory of Open Access Journals (Sweden)

    Venkateswara Sarma Mallela

    2004-10-01

    Full Text Available Batteries used in Implantable cardiac pacemakers-present unique challenges to their developers and manufacturers in terms of high levels of safety and reliability. In addition, the batteries must have longevity to avoid frequent replacements. Technological advances in leads/electrodes have reduced energy requirements by two orders of magnitude. Micro-electronics advances sharply reduce internal current drain concurrently decreasing size and increasing functionality, reliability, and longevity. It is reported that about 600,000 pacemakers are implanted each year worldwide and the total number of people with various types of implanted pacemaker has already crossed 3 million. A cardiac pacemaker uses half of its battery power for cardiac stimulation and the other half for housekeeping tasks such as monitoring and data logging. The first implanted cardiac pacemaker used nickel-cadmium rechargeable battery, later on zinc-mercury battery was developed and used which lasted for over 2 years. Lithium iodine battery invented and used by Wilson Greatbatch and his team in 1972 made the real impact to implantable cardiac pacemakers. This battery lasts for about 10 years and even today is the power source for many manufacturers of cardiac pacemakers. This paper briefly reviews various developments of battery technologies since the inception of cardiac pacemaker and presents the alternative to lithium iodine battery for the near future.

  4. [Cardiac cachexia].

    Science.gov (United States)

    Miján, Alberto; Martín, Elvira; de Mateo, Beatriz

    2006-05-01

    Chronic heart failure (CHF), especially affecting the right heart, frequently leads to malnutrition. If the latter is severe and is combined to other factors, it may lead to cardiac cachexia. This one is associated to increased mortality and lower survival of patients suffering from it. The causes of cardiac cachexia are diverse, generally associated to maintenance of a negative energy balance, with increasing evidence of its multifactorial origin. Neurohumoral, inflammatory, immunological, and metabolic factors, among others, are superimposed in the patient with CHF, leading to involvement and deterioration of several organs and systems, since this condition affects both lean (or active cellular) mass and adipose and bone tissue osteoporosis. Among all, the most pronounced deterioration may be seen at skeletal muscle tissue, at both structural and functional levels, the heart not being spared. As for treatment, it should be based on available scientific evidence. Assessment of nutritional status of any patient with CHF is a must, with the requirement of nutritional intervention in case of malnutrition. In this situation, especially if accompanied by cardiac cachexia, it is required to modify energy intake and oral diet quality, and to consider the indication of specific complementary or alternative artificial nutrition. Besides, the causal relationship of the beneficial role of moderate physical exertion is increasing, as well as modulation of metabolic and inflammatory impairments observed in cardiac cachexia with several drugs, leading to a favorable functional and structural response in CHF patients.

  5. Cardiac Pacemakers

    International Nuclear Information System (INIS)

    Fiandra, O.; Espasandin, W.; Fiandra, H.

    1984-01-01

    A complete survey of physiological biophysical,clinical and engineering aspects of cardiac facing,including the history and an assessment of possible future developments.Among the topics studied are: pacemakers, energy search, heart stimulating with pacemakers ,mathematical aspects of the electric cardio stimulation chronic, pacemaker implants,proceeding,treatment and control

  6. Cardiac nuclear medicine

    Energy Technology Data Exchange (ETDEWEB)

    Gerson, M.C.

    1987-01-01

    The book begins with a review of the radionuclide methods available for evaluating cardiac perfusion and function. The authors discuss planar and tomographic thallium myocardial imaging, first-pass and equilibrium radionuclide angiography, and imaging with infarct-avid tracers. Several common but more specialized procedures are then reviewed: nonogemetric measurement of left ventricular volume, phase (Fourier) analysis, stroke volume ratio, right ventricular function, and diastolic function. A separate chapter is devoted to drug interventions and in particular the use of radionuclide ventriculography to monitor doxorubicin toxicity and therapy of congestive heart failure. The subsequent chapters provide a comprehensive guide to test selection, accuracy, and results in acute myocardial infarction, in postmyocardial infarction, in chronic coronary artery disease, before and after medical or surgical revascularization, in valvular heart disease, in cardiomyopathies, and in cardiac trauma.

  7. Cardiac nuclear medicine

    International Nuclear Information System (INIS)

    Gerson, M.C.

    1987-01-01

    The book begins with a review of the radionuclide methods available for evaluating cardiac perfusion and function. The authors discuss planar and tomographic thallium myocardial imaging, first-pass and equilibrium radionuclide angiography, and imaging with infarct-avid tracers. Several common but more specialized procedures are then reviewed: nonogemetric measurement of left ventricular volume, phase (Fourier) analysis, stroke volume ratio, right ventricular function, and diastolic function. A separate chapter is devoted to drug interventions and in particular the use of radionuclide ventriculography to monitor doxorubicin toxicity and therapy of congestive heart failure. The subsequent chapters provide a comprehensive guide to test selection, accuracy, and results in acute myocardial infarction, in postmyocardial infarction, in chronic coronary artery disease, before and after medical or surgical revascularization, in valvular heart disease, in cardiomyopathies, and in cardiac trauma

  8. The effect of garden designs on mood and heart output in older adults residing in an assisted living facility.

    Science.gov (United States)

    Goto, Seiko; Park, Bum-Jin; Tsunetsugu, Yuko; Herrup, Karl; Miyazaki, Yoshifumi

    2013-01-01

    The objective of this study is to trace short-term changes in mood and heart function in elderly individuals in response to exposure to different landscaped spaces. Nineteen elderly but cognitively intact residents of an assisted living facility participated in the study. They were exposed to three landscaped spaces: a Japanese style garden, an herb garden, and a simple landscaped area planted with a single tree. To assess the effect of different landscaped spaces on older adults, individuals were monitored for mood and cardiac function in response to short exposures to spaces. Mood state was assessed using Profile of Mood States (POMS) before and after viewing the spaces. Cardiac output was assessed using a portable electrocardiograph monitor before and during the viewing. We found that the structured gardens evoked greater responses in all outcome measures. Scores on the POMS improved after observation of the two organized gardens compared to responses to the simple landscaped space with a single tree. During the observation period, heart rate was significantly lower in the Japanese garden than in the other environments, and sympathetic function was significantly lower as well. We conclude that exposure to organized gardens can affect both the mood and cardiac physiology of elderly individuals. Our data further suggest that these effects can differ depending on the types of landscape to which an individual is exposed. Elderly, Japanese garden, herb garden, heart rate, mood, healing environmentPreferred Citation: Goto, S., Park, B-J., Tsunetsugu, Y., Herrup, K., & Miyazaki, Y. (2013). The effect of garden designs on mood and heart output in older adults residing in an assisted living facility. Health Environments Research & Design Journal 6(2), pp 27-42.

  9. National Cardiac Device Surveillance Program Database

    Data.gov (United States)

    Department of Veterans Affairs — The National Cardiac Device Surveillance Program Database supports the Eastern Pacemaker Surveillance Center (EPSC) staff in its function of monitoring some 11,000...

  10. Cardiac ablation

    Directory of Open Access Journals (Sweden)

    Kelly Ratheal

    2016-01-01

    Full Text Available Cardiac ablation is a procedure that uses either radiofrequency or cryothermal energy to destroy cells in the heart to terminate and/or prevent arrhythmias. The indications for cardiac catheter ablation include refractory, symptomatic arrhythmias, with more specific guidelines for atrial fibrillation in particular. The ablation procedure itself involves mapping the arrhythmia and destruction of the aberrant pathway in an effort to permanently prevent the arrhythmia. There are many types of arrhythmias, and they require individualized approaches to ablation based on their innately different electrical pathways. Ablation of arrhythmias, such as Wolff-Parkinson-White syndrome, AV nodal reentrant tachycardia, and atrial-fibrillation, is discussed in this review. Ablation has a high success rate overall and minimal complication rates, leading to improved quality of life in many patients.

  11. Evaluation of the cardiac efficiency by means of functional radiocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Scheibe, J; Stoll, W [Friedrich-Schiller-Universitaet, Jena (German Democratic Republic). Bereich Medizin

    1982-01-01

    A new method of evaluating the cardiac efficiency by means of radiocardiography performed on exertion with /sup 113m/InCl is reported. Analysis of stroke volume, end diastolic volume and of the quotient of cardiac output to end diastolic volume on exertion enables an adequate evaluation of the actual myocardial efficiency.

  12. Commissioning of output factors for uniform scanning proton beams

    International Nuclear Information System (INIS)

    Zheng Yuanshui; Ramirez, Eric; Mascia, Anthony; Ding Xiaoning; Okoth, Benny; Zeidan, Omar; Hsi Wen; Harris, Ben; Schreuder, Andries N.; Keole, Sameer

    2011-01-01

    Purpose: Current commercial treatment planning systems are not able to accurately predict output factors and calculate monitor units for proton fields. Patient-specific field output factors are thus determined by either measurements or empirical modeling based on commissioning data. The objective of this study is to commission output factors for uniform scanning beams utilized at the ProCure proton therapy centers. Methods: Using water phantoms and a plane parallel ionization chamber, the authors first measured output factors with a fixed 10 cm diameter aperture as a function of proton range and modulation width for clinically available proton beams with ranges between 4 and 31.5 cm and modulation widths between 2 and 15 cm. The authors then measured the output factor as a function of collimated field size at various calibration depths for proton beams of various ranges and modulation widths. The authors further examined the dependence of the output factor on the scanning area (i.e., uncollimated proton field), snout position, and phantom material. An empirical model was developed to calculate the output factor for patient-specific fields and the model-predicted output factors were compared to measurements. Results: The output factor increased with proton range and field size, and decreased with modulation width. The scanning area and snout position have a small but non-negligible effect on the output factors. The predicted output factors based on the empirical modeling agreed within 2% of measurements for all prostate treatment fields and within 3% for 98.5% of all treatment fields. Conclusions: Comprehensive measurements at a large subset of available beam conditions are needed to commission output factors for proton therapy beams. The empirical modeling agrees well with the measured output factor data. This investigation indicates that it is possible to accurately predict output factors and thus eliminate or reduce time-consuming patient-specific output

  13. Inverter communications using output signal

    Science.gov (United States)

    Chapman, Patrick L.

    2017-02-07

    Technologies for communicating information from an inverter configured for the conversion of direct current (DC) power generated from an alternative source to alternating current (AC) power are disclosed. The technologies include determining information to be transmitted from the inverter over a power line cable connected to the inverter and controlling the operation of an output converter of the inverter as a function of the information to be transmitted to cause the output converter to generate an output waveform having the information modulated thereon.

  14. Effects of exercise rehabilitation on cardiac electrical instability assessed by T-wave alternans during ambulatory electrocardiogram monitoring in coronary artery disease patients without and with diabetes mellitus.

    Science.gov (United States)

    Kenttä, Tuomas; Tulppo, Mikko P; Nearing, Bruce D; Karjalainen, Jaana J; Hautala, Arto J; Kiviniemi, Antti M; Huikuri, Heikki V; Verrier, Richard L

    2014-09-15

    Effects of exercise rehabilitation on electrocardiographic markers of risk for sudden cardiac death have not been adequately studied. We examined effects of controlled exercise training on T-wave alternans (TWA) in 24-hour ambulatory electrocardiogram recordings in patients with stable coronary artery disease (CAD) without and with type 2 diabetes mellitus (DM). Consecutive patients with angiographically confirmed CAD were recruited to join the ARTEMIS (Innovation to Reduce Cardiovascular Complications of Diabetes at the Intersection) study. Exercise (n = 65) and control groups (n = 65) were matched on age, sex, DM, and previous myocardial infarction. Ambulatory electrocardiograms were recorded before and after a 2-year training period. TWA was assessed using time domain-modified moving average method by an investigator blinded to patients' clinical status. Average TWA values decreased in the rehabilitation group but not in control patients (rehabilitation [mean ± SEM]: 52.8 ± 1.7 μV vs 48.7 ± 1.5 μV, p exercise versus 10% (n = 2 of 20) of controls (p = 0.020). In CAD patients, 30% (n = 8 of 27) of positive TWA cases were converted with exercise versus 4% (n = 1 of 28) of controls (p = 0.012). In conclusion, this is the first report of the effectiveness of exercise rehabilitation to reduce TWA, a marker of sudden cardiac death risk, in patients with stable CAD. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Effect of alectinib on cardiac electrophysiology: results from intensive electrocardiogram monitoring from the pivotal phase II NP28761 and NP28673 studies.

    Science.gov (United States)

    Morcos, Peter N; Bogman, Katrijn; Hubeaux, Stanislas; Sturm-Pellanda, Carolina; Ruf, Thorsten; Bordogna, Walter; Golding, Sophie; Zeaiter, Ali; Abt, Markus; Balas, Bogdana

    2017-03-01

    Alectinib, a central nervous system (CNS)-active ALK inhibitor, has demonstrated efficacy and safety in ALK+ non-small-cell lung cancer that has progressed following crizotinib treatment. Other ALK inhibitors have shown concentration-dependent QTc prolongation and treatment-related bradycardia. Therefore, this analysis evaluated alectinib safety in terms of electrophysiologic parameters. Intensive triplicate centrally read electrocardiogram (ECG) and matched pharmacokinetic data were collected across two alectinib single-arm trials. Analysis of QTcF included central tendency analysis [mean changes from baseline with one-sided upper 95% confidence intervals (CIs)], categorical analyses, and relationship between change in QTcF and alectinib plasma concentrations. Alectinib effects on other ECG parameters (heart rate, PR interval and QRS duration) were also evaluated. Alectinib did not cause a clinically relevant change in QTcF. The maximum mean QTcF change from baseline was 5.3 ms observed pre-dose at week 2. The upper one-sided 95% CI was exposure-dependent decrease in mean heart rate of ~11 to 13 beats per minute at week 2. No clinically relevant effects were seen on other ECG parameters. Approximately 5% of patients reported cardiac adverse events of bradycardia or sinus bradycardia; however, these were all grade 1-2. Alectinib does not prolong the QTc interval or cause changes in cardiac function to a clinically relevant extent, with the exception of a decrease in heart rate which was generally asymptomatic.

  16. [Prediction of cardiac function deviations (ECG data) in the course of permanent cosmonaut's monitoring starting from selection till return to earth after short-duration space flight].

    Science.gov (United States)

    Kotovskaia, A R; Koloteva, M I; Luk'ianiuk, V Iu; Stepanova, G P; Filatova, L M; Buĭlov, S P; Zhernavkov, A F; Kondratiuk, L L

    2007-01-01

    Analyzed were deviations in cardiac function in 29 cosmonauts with previous aviation and other occupations ranging of 29 to 61 y.o. who made 8- to 30-day space flights (totai number of flights = 34) between 1982 and 2006. The deviations were identified in ECG records collected during clinical selection, clinical physiological examination (CPE) before flight, insertion and deorbit in transport vehicles, and post-flight CPE. Based on the analysis, the cosmonauts were distributed into three groups. The first group (55.2% of the cosmonauts) did not exhibit noticeable shifts and unfavorable trends in ECG at any time of the period of observation. The second group (34.5%) showed some deviations during selection and pre-flight CPE that became more apparent in the period of deorbit and were still present in post-flight ECG records. The third group (10.3%) displayed health-threatening deviations in cardiac function during deorbit. These findings give start to important investigations with the purpose to define permissible medical risks and ensuing establishment and perfection of medical criteria for candidates to cosmonauts with certain health problems.

  17. Human technology after cardiac epigenesis. Artificial heart versus cardiac transplantation.

    Science.gov (United States)

    Losman, J G

    1977-09-24

    Cardiovascular disease is the chief cause of death in technologically advanced countries and accounts for more than 50% of all deaths in the USA. For a patient with end-stage cardiac failure the only treatment presently available is organ replacement, either by transplantation or by the use of a mechanical heart. Transplantation has demonstrated its value: survival of more than 8 years and restoration of a normal quality of life to patients who were in end-stage cardiac decompensation. However, the prospect of routine clinical application of an artificial heart remains distant. The development of a totally implantable artificial heart still presents a series of challenging engineering problems with regard to strict constraints of size, weight, blood-material compatibility, adaptability of output to demand, efficiency and reliability of the power supply, and safety if nuclear fuel is used. The totally artificial heart is presently not an alternative to the cardiac allograft, but could provide short-term support for patients awaiting cardiac transplantation.

  18. Enhanced performance CCD output amplifier

    Science.gov (United States)

    Dunham, Mark E.; Morley, David W.

    1996-01-01

    A low-noise FET amplifier is connected to amplify output charge from a che coupled device (CCD). The FET has its gate connected to the CCD in common source configuration for receiving the output charge signal from the CCD and output an intermediate signal at a drain of the FET. An intermediate amplifier is connected to the drain of the FET for receiving the intermediate signal and outputting a low-noise signal functionally related to the output charge signal from the CCD. The amplifier is preferably connected as a virtual ground to the FET drain. The inherent shunt capacitance of the FET is selected to be at least equal to the sum of the remaining capacitances.

  19. Comparative cardiac toxicity of anthracyclines in vitro and in vivo in the mouse.

    Directory of Open Access Journals (Sweden)

    Stefano Toldo

    Full Text Available PURPOSE: The antineoplastic efficacy of anthracyclines is limited by their cardiac toxicity. In this study, we evaluated the toxicity of doxorubicin, non-pegylated liposomal-delivered doxorubicin, and epirubicin in HL-1 adult cardiomyocytes in culture as well as in the mouse in vivo. METHODS: The cardiomyocytes were incubated with the three anthracyclines (1 µM to assess reactive oxygen generation, DNA damage and apoptotic cell death. CF-1 mice (10/group received doxorubicin, epirubicin or non-pegylated liposomal-doxorubicin (10 mg/kg and cardiac function was monitored by Doppler echocardiography to measure left ventricular ejection fraction (LVEF, heart rate (HR and cardiac output (CO both prior to and 10 days after drug treatment. RESULTS: In HL-1 cells, non-pegylated liposomal-doxorubicin generated significantly less reactive oxygen species (ROS, as well as less DNA damage and apoptosis activation when compared with doxorubicin and epirubicin. Cultured breast tumor cells showed similar sensitivity to the three anthracyclines. In the healthy mouse, non-pegylated liposomal doxorubicin showed a minimal and non-significant decrease in LVEF with no change in HR or CO, compared to doxorubicin and epirubicin. CONCLUSION: This study provides evidence for reduced cardiac toxicity of non-pegylated-liposomal doxorubicin characterized by attenuation of ROS generation, DNA damage and apoptosis in comparison to epirubicin and doxorubicin.

  20. Use of Human Induced Pluripotent Stem Cell-Derived Cardiomyocytes (hiPSC-CMs) to Monitor Compound Effects on Cardiac Myocyte Signaling Pathways.

    Science.gov (United States)

    Guo, Liang; Eldridge, Sandy; Furniss, Mike; Mussio, Jodie; Davis, Myrtle

    2015-09-01

    There is a need to develop mechanism-based assays to better inform risk of cardiotoxicity. Human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) are rapidly gaining acceptance as a biologically relevant in vitro model for use in drug discovery and cardiotoxicity screens. Utilization of hiPSC-CMs for mechanistic investigations would benefit from confirmation of the expression and activity of cellular pathways that are known to regulate cardiac myocyte viability and function. This unit describes an approach to demonstrate the presence and function of signaling pathways in hiPSC-CMs and the effects of treatments on these pathways. We present a workflow that employs protocols to demonstrate protein expression and functional integrity of signaling pathway(s) of interest and to characterize biological consequences of signaling modulation. These protocols utilize a unique combination of structural, functional, and biochemical endpoints to interrogate compound effects on cardiomyocytes. Copyright © 2015 John Wiley & Sons, Inc.

  1. Three-dimensional display and measurement of cardiac dynamic indexes from MR images

    International Nuclear Information System (INIS)

    Kono, M.; Matsuo, M.; Yamasaki, K.; Banno, T.; Toriwaki, J.; Yokoi, S.; Oshita, H.

    1986-01-01

    The cardiac dynamic index, to which such variables as cardiac output, ejection fraction, and wall motion contribute, is routinely determined using various modalities such as angiography, radionuclide imaging, US, and x-ray CT. Each of these modalities, however, has some disadvantages in regard to evaluating the cardiac dynamic index. The authors have obtained precise multidirectional projection images of the heart by means of computer graphics and reformatted data of cardiac MR images obtained with cardiac gating. The contiguous coronal MR images of the heart are made at an interimage distance of 5 mm. In each section, five or six cardiac images can be obtained, depending on the systolic or diastolic phase. These images are stored in a computer, and a three-dimensional display of the heart with biocular observation and with multiplex holograms is made possible with computer graphics. Three-dimensional measurement of the cardiac index is now being attempted, including cardiac output, ejection fraction, and wall motion

  2. Débito cardíaco e fração de ejeção fetal por meio do spatio-temporal image correlation (STIC: comparação entre fetos masculinos e femininos Fetal cardiac output and ejection fraction by spatio-temporal image correlation (STIC: comparison between male and female fetuses

    Directory of Open Access Journals (Sweden)

    Christiane Simioni

    2012-06-01

    Full Text Available OBJETIVO: Comparar do débito cardíaco (DC e a fração de ejeção (FE do coração de fetos masculinos e femininos obtidos por meio da ultrassonografia tridimensional, utilizando o spatio-temporal image correlation (STIC. MÉTODOS: Realizou-se um estudo de corte transversal com 216 fetos normais, entre 20 a 34 semanas de gestação, sendo 108 masculinos e 108 femininos. Os volumes ventriculares no final da sístole e diástole foram obtidos por meio do STIC, sendo as avaliações volumétricas realizadas pelo virtual organ computer-aided analysis (VOCAL com rotação de 30º. Para o cálculo do DC utilizou-se a fórmula: DC= volume sistólico/frequência cardíaca fetal, enquanto que para a FE utilizou-se a fórmula: FE= volume sistólico/volume diastólico final. O DC (combinado, feminino e masculino e a FE (masculina e feminina foram comparadas utilizando-se o teste t não pareado e ANCOVA. Foram criados gráficos de dispersão com os percentis 5, 50 e 95. RESULTADOS: A média do DC combinado, DC direito, DC esquerdo, FE direita e FE esquerda, para feminino e masculino, foram 240,07 mL/min; 122,67 mL/min; 123,40 mL/min; 72,84%; 67,22%; 270,56 mL/min; 139,22 mL/min; 131,34 mL/min; 70,73% e 64,76%, respectivamente; sem diferença estatística (P> 0,05. CONCLUSÕES: O DC e a FE fetal obtidos por meio da ultrassonografia tridimensional (STIC não apresentaram diferença significativa em relação ao gênero.OBJECTIVE: To compare the cardiac output (CO and ejection fraction (EF of the heart of male and female fetuses obtained by 3D-ultrasonography using spatio-temporal image correlation (STIC. METHODS: We conducted a cross-sectional study with 216 normal fetuses, between 20 and 34 weeks of gestation, 108 male and 108 female. Ventricular volumes at the end of systole and diastole were obtained by STIC, and the volumetric assessments performed by the virtual organ computer-aided analysis (VOCAL rotated 30º. To calculate the DC used the formula

  3. Perioperative Rosuvastatin in Cardiac Surgery.

    Science.gov (United States)

    Zheng, Zhe; Jayaram, Raja; Jiang, Lixin; Emberson, Jonathan; Zhao, Yan; Li, Qi; Du, Juan; Guarguagli, Silvia; Hill, Michael; Chen, Zhengming; Collins, Rory; Casadei, Barbara

    2016-05-05

    Complications after cardiac surgery are common and lead to substantial increases in morbidity and mortality. Meta-analyses of small randomized trials have suggested that perioperative statin therapy can prevent some of these complications. We randomly assigned 1922 patients in sinus rhythm who were scheduled for elective cardiac surgery to receive perioperative rosuvastatin (at a dose of 20 mg daily) or placebo. The primary outcomes were postoperative atrial fibrillation within 5 days after surgery, as assessed by Holter electrocardiographic monitoring, and myocardial injury within 120 hours after surgery, as assessed by serial measurements of the cardiac troponin I concentration. Secondary outcomes included major in-hospital adverse events, duration of stay in the hospital and intensive care unit, left ventricular and renal function, and blood biomarkers. The concentrations of low-density lipoprotein cholesterol and C-reactive protein after surgery were lower in patients assigned to rosuvastatin than in those assigned to placebo (PSTICS ClinicalTrials.gov number, NCT01573143.).

  4. Cerebral Oximetry in Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    A. N. Shepelyuk

    2012-01-01

    Full Text Available Based on the data of numerous current references, the review describes different neuromonitoring methods during cardiac surgery under extracorporeal circulation. It shows that it is important and necessary to make neuromonitoring for the early diagnosis and prevention of neurological complications after cardiac surgery. Particular attention is given to cerebral oximetry; the possibilities and advantages of this technique are described. Correction of cerebral oximetric values is shown to improve survival rates and to reduce the incidence of postoperative complications. Lack of cerebral oximetry monitoring denudes a clinician of important information and possibilities to optimize patient status and to prevent potentially menacing complications, which allows one to conclude that it is necessary to use cerebral oximetry procedures within neu-romonitoring in cardiac surgery. Key words: extracorporeal circulation, cerebral oximetry, neurological dysfunction, cerebral oxygenation.

  5. GDP Growth, Potential Output, and Output Gaps in Mexico

    OpenAIRE

    Ebrima A Faal

    2005-01-01

    This paper analyzes the sources of Mexico's economic growth since the 1960s and compares various decompositions of historical growth into its trend and cyclical components. The role of the implied output gaps in the inflationary process is then assessed. Looking ahead, the paper presents medium-term paths for GDP based on alternative assumptions for productivity growth rates. The results indicate that the most important factor underlying the slowdown in output growth was a decline in trend to...

  6. Cardiac pacemaker

    International Nuclear Information System (INIS)

    Kolenik, S.A.

    1976-01-01

    The construction of a cardiac pacemaker is described which is characterized by particularly small dimensions, small weight and long life duration. The weight is under 100g, the specific weight under 1.7. Mass inertia forces which occur through acceleration and retardation processes, thus remain below the threshold values, above which one would have to reckon with considerable damaging of the surrounding body tissue. The maintaining of small size and slight weight is achieved by using an oscillator on COSMOS basis, where by considerably lower energy consumption, amongst others the lifetimes of the batteries used - a lithium anode with thionyl chloride electrolyte - is extended to over 5 years. The reliability can be increased by the use of 2 or more batteries. The designed dimension are 20x60x60 mm 3 . (ORU/LH) [de

  7. Cardiac ventriculography

    International Nuclear Information System (INIS)

    Hillis, L.D.; Grossman, W.

    1986-01-01

    Cardiac ventriculography has been used extensively to define the anatomy of the ventricles and related structures in patients with congenital, valvular, coronary, and cardiomyopathic heart disease. Specifically, left ventriculography may provide valuable information about global and segmental left ventricular function, mitral valvular incompetence, and the presence, location, and severity of a number of other abnormalities, including ventricular septal defect and hypertrophic cardiomyopathy. As a result, it should be a routine part of catheterization in patients being evaluated for coronary artery disease, aortic or mitral valvular disease, unexplained left ventricular failure, or congenital heart disease. Similarly, right ventriculography may provide information about global and segmental right ventricular function and can be especially helpful in patients with congenital heart disease

  8. Limited proteolysis combined with isotope labeling and quantitative LC-MALDI MS for monitoring protein conformational changes: a study on calcium-binding sites of cardiac Troponin C

    International Nuclear Information System (INIS)

    McDonald, Chris; Li Liang

    2005-01-01

    Studies of protein-protein and protein-ligand interactions are important for understanding biological functions of proteins. A new technique based on the partial proteolysis of proteins combined with quantitative mass spectrometry is developed as a means of tracking structural changes after the formation of a protein-ligand complex. In this technique, a protein of interest with and without the binding of a ligand is digested with an enzyme to generate a set of peptides, followed by separation of the peptides by liquid chromatography. Matrix-assisted laser desorption ionization (MALDI) mass spectrometry (MS) is used to identify chromatographically separated peptides, and locate their sequence alignments in the parent protein. Using an isotopically labeled protein as a sample against an unlabeled protein standard, quantitative information can be gathered. This overcomes the inherent lack of quantitative capability of MALDI MS. The utility of the technique to investigate protein-ligand interactions is demonstrated in a model system involving calcium binding to cardiac Troponin C (cTnC). Using this technique, the general location of the three calcium-binding sites of cTnC can be determined by using several different enzymes to generate overlapping peptide maps of cTnC

  9. Output

    DEFF Research Database (Denmark)

    Mehlsen, Camilla

    2010-01-01

    Hvad får vi egentlig ud af internationale komparative undersøgelser som PISA, PIRLS og TIMSS? Hvordan påvirker de dansk uddannelsespolitik? Asterisk har talt med tre forskere med ekspertise på området.......Hvad får vi egentlig ud af internationale komparative undersøgelser som PISA, PIRLS og TIMSS? Hvordan påvirker de dansk uddannelsespolitik? Asterisk har talt med tre forskere med ekspertise på området....

  10. Avaliação da correlação entre o dióxido de carbono expirado e o débito cardíaco em pacientes submetidos à cirurgia cardíaca com circulação extracorpórea Evaluación de la correlación entre el dióxido de carbono expirado y el débito cardíaco en pacientes sometidos a la cirugía cardíaca con circulación extracorpórea Correlation between end-tidal carbon dioxide levels and cardiac output during cardiac surgery with cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Karina Takesaki Miyaji

    2004-10-01

    reflects pulmonary blood perfusion, thus cardiac output (CO. This study aimed at evaluating the correlation between P ET CO2 levels and CO during cardiac surgery with cardiopulmonary bypass (CPB. METHODS: Participated in this study 25 patients submitted to coronary artery bypass grafting (CABG with CPB. End-tidal CO2 monitoring started after tracheal intubation. Cardiac output was determined by thermodilution with pulmonary artery catheter (Swan-Ganz. Carbon dioxide partial blood pressure (PaCO2 was obtained with arterial blood gases analysis. Studied parameters were evaluated in the following moments: immediately after general anesthesia induction, before cardiopulmonary bypass, at cardiopulmonary bypass completion and at surgery completion. RESULTS: Statistical analysis has not shown correlation between P ET CO2 and CO2, or between P ET CO2-PaCO2 gradient (Ga-eCO2 and CO. There has been correlation between P ET CO2, Ga-eCO2 and CO values variation as compared to baseline values before CPB, with loss of correlation after CPB until surgery completion. CONCLUSIONS: In this study, where patients submitted to cardiac surgery with CPB were evaluated, ventilation/perfusion changes throughout the procedure might have been the factors determining decreased correlation between cardiac output and end tidal CO2.

  11. [Meta-analyses on measurement precision of non-invasive hemodynamic monitoring technologies in adults].

    Science.gov (United States)

    Pestel, G; Fukui, K; Higashi, M; Schmidtmann, I; Werner, C

    2018-06-01

    An ideal non-invasive monitoring system should provide accurate and reproducible measurements of clinically relevant variables that enables clinicians to guide therapy accordingly. The monitor should be rapid, easy to use, readily available at the bedside, operator-independent, cost-effective and should have a minimal risk and side effect profile for patients. An example is the introduction of pulse oximetry, which has become established for non-invasive monitoring of oxygenation worldwide. A corresponding non-invasive monitoring of hemodynamics and perfusion could optimize the anesthesiological treatment to the needs in individual cases. In recent years several non-invasive technologies to monitor hemodynamics in the perioperative setting have been introduced: suprasternal Doppler ultrasound, modified windkessel function, pulse wave transit time, radial artery tonometry, thoracic bioimpedance, endotracheal bioimpedance, bioreactance, and partial CO 2 rebreathing have been tested for monitoring cardiac output or stroke volume. The photoelectric finger blood volume clamp technique and respiratory variation of the plethysmography curve have been assessed for monitoring fluid responsiveness. In this manuscript meta-analyses of non-invasive monitoring technologies were performed when non-invasive monitoring technology and reference technology were comparable. The primary evaluation criterion for all studies screened was a Bland-Altman analysis. Experimental and pediatric studies were excluded, as were all studies without a non-invasive monitoring technique or studies without evaluation of cardiac output/stroke volume or fluid responsiveness. Most studies found an acceptable bias with wide limits of agreement. Thus, most non-invasive hemodynamic monitoring technologies cannot be considered to be equivalent to the respective reference method. Studies testing the impact of non-invasive hemodynamic monitoring technologies as a trend evaluation on outcome, as well as

  12. Cardiac regeneration therapy: connections to cardiac physiology.

    Science.gov (United States)

    Takehara, Naofumi; Matsubara, Hiroaki

    2011-12-01

    Without heart transplantation, a large number of patients with failing hearts worldwide face poor outcomes. By means of cardiomyocyte regeneration, cardiac regeneration therapy is emerging with great promise as a means for restoring loss of cardiac function. However, the limited success of clinical trials using bone marrow-derived cells and myoblasts with heterogeneous constituents, transplanted at a wide range of cell doses, has led to disagreement on the efficacy of cell therapy. It is therefore essential to reevaluate the evidence for the efficacy of cell-based cardiac regeneration therapy, focusing on targets, materials, and methodologies. Meanwhile, the revolutionary innovation of cardiac regeneration therapy is sorely needed to help the millions of people who suffer heart failure from acquired loss of cardiomyocytes. Cardiac regeneration has been used only in limited species or as a developing process in the rodent heart; now, the possibility of cardiomyocyte turnover in the human heart is being revisited. In the pursuit of this concept, the use of cardiac stem/progenitor stem cells in the cardiac niche must be focused to usher in a second era of cardiac regeneration therapy for the severely injured heart. In addition, tissue engineering and cellular reprogramming will advance the next era of treatment that will enable current cell-based therapy to progress to "real" cardiac regeneration therapy. Although many barriers remain, the prevention of refractory heart failure through cardiac regeneration is now becoming a realistic possibility.

  13. Conventional hemofiltration during cardiopulmonary bypass increases the serum lactate level in adult cardiac surgery

    Directory of Open Access Journals (Sweden)

    Rabie Soliman

    2016-01-01

    Full Text Available Objective: To evaluate the effect of hemofiltration during cardiopulmonary bypass on lactate level in adult patients who underwent cardiac surgery. Design: An observational study. Setting: Prince Sultan cardiac center, Riyadh, Saudi Arabia. Participants: The study included 283 patients classified into two groups: Hemofiltration group (n=138, hemofiltration was done during CPB. Control group (n = 145, patients without hemofiltration. Interventions: Hemofiltration during cardiopulmonary bypass. Measurements and Main Results: Monitors included hematocrit, lactate levels, mixed venous oxygen saturation, amount of fluid removal during hemofiltration and urine output. The lactate elevated in group H than group C (P < 0.05, and the PH showed metabolic acidosis in group H (P < 0.05. The mixed venous oxygen saturation decreased in group H than group C (P < 0.05. The number of transfused packed red blood cells was lower in group H than group C (P < 0.05. The hematocrit was higher in group H than group C (P < 0.05. The urine output was lower in group H than group C (P < 0.05. Conclusions: Hemofiltration during cardiopulmonary bypass leads to hemoconcentration, elevated lactate level and increased inotropic support. There are some recommendations for hemofiltration: First; Hemofiltration should be limited for patients with impaired renal function, positive fluid balance, reduced response to diuretics or prolonged bypass time more than 2 hours. Second; Minimal amount of fluids should be administered to maintain adequate cardiac output and reduction of priming volumes is preferable to maintain controlled hemodilution. Third; it should be done before weaning of or after cardiopulmonary bypass and not during the whole time of cardiopulmonary bypass.

  14. Fiberoptic monitoring of central venous oxygen saturation (PediaSat in small children undergoing cardiac surgery: continuous is not continuous [v3; ref status: indexed, http://f1000r.es/3qt

    Directory of Open Access Journals (Sweden)

    Francesca G. Iodice

    2014-06-01

    Full Text Available Background: Monitoring of superior vena cava saturation (ScvO2 has become routine in the management of pediatric patients undergoing cardiac surgery. The objective of our study was to evaluate the correlation between continuous ScvO2 by the application of a fiber-optic oximetry catheter (PediaSat and intermittent ScvO2 by using standard blood gas measurements. These results were compared to those obtained by cerebral near infrared spectroscopy (cNIRS. Setting: Tertiary pediatric cardiac intensive care unit (PCICU. Methods and main results: A retrospective study was conducted in consecutive patients who were monitored with a 4.5 or 5.5 F PediaSat catheter into the right internal jugular vein. An in vivo calibration was performed once the patient was transferred to the PCICU and re-calibration took place every 24 hours thereafter. Each patient had a NIRS placed on the forehead. Saturations were collected every 4 hours until extubation. Ten patients with a median age of 2.2 (0.13-8.5 years and a weight of 12.4 (3.9-24 kg were enrolled. Median sampling time was 32 (19-44 hours: 64 pairs of PediaSat and ScVO2 saturations showed a poor correlation (r=0.62, 95% CI 44-75; p<0.0001 and Bland Altman analysis for repeated measures showed an average difference of 0.34 with a standard deviation of 7,9 and 95% limits of agreement from -15 to 16. Thirty-six pairs of cNIRS and ScVO2 saturations showed a fair correlation (r=0.79, 95% CI 0.60-0.89; p<0.0001 an average difference of -1.4 with a standard deviation of 6 and 95% limits of agreement from -13 to 10. Analysis of median percentage differences between PediaSat and ScvO2 saturation over time revealed that, although not statistically significant, the change in percentage saturation differences was clinically relevant after the 8th hour from calibration (from -100 to +100%. Conclusion: PediaSat catheters showed unreliable performance in our cohort. It should be further investigated whether repeating

  15. Incidencia de eventos vasculares mayores después de cirugía no cardiaca: impacto del monitoreo perioperatorio con troponina y electrocardiograma Incidence of major vascular events after cardiac surgery: impact of preoperative monitoring with troponin and electrocardiogram

    Directory of Open Access Journals (Sweden)

    Sandra M Quiroga

    2009-06-01

    led to an increased risk of major vascular events among patients undergoing non-cardiac surgery. Troponin and electrocardiogram monitoring would further identify these major vascular events. Methods: we prospectively collected data on elegible patients (non-selected individuals aged 45 or older undergoing non-cardiac surgery under general or regional anesthesia in two hospitals in Bucaramanga, with expected length of stay longer than 24 hours during a time-interrupted series, before and after postoperative diagnostic monitoring (blinded assessment of troponin T and electrocardiograms ignoring clinical data. For the period before the intervention (usual clinical care, two independent reviewers extracted clinical information from clinical histories (of all eligible patients from 3 randomly-selected months of 2005. For the period after diagnostic monitoring, we followed 100 consecutive eligible patients. Primary outcome was a composite of major vascular events within hospital, including myocardial infarction (defined as any troponin elevation associated with electrocardiographic changes suggesting ischemia, regardless of symptoms. Results: we included 534 clinical charts and 100 prospective surgical patients (mean age 62.2, SD 12.9 years; 56% women. The more frequent surgical procedures were orthopedics (26.8% followed by abdominal (20.2%. The incidence of major vascular events recorded in clinical charts was 2.8%, compared with 7% among monitored patients (p=0,071. All four myocardial infarctions identified among the later group were silent. Conclusion: postoperative monitoring with troponin and electrocardiography identified a higher proportion of major vascular events, mainly silent myocardial infarctions.

  16. Débito cardíaco diminuído: revisão sistemática das características definidoras Débito cardíaco disminuído: revisión sistemática de las características definidoras Decreased cardiac output: a systematic review of the defining characteristics

    Directory of Open Access Journals (Sweden)

    Vanessa de Souza

    2011-01-01

    explorada. Se constató la importancia del examen físico, la utilización de técnicas menos invasivas y la necesidad de revisar las características definidoras propuestas a fin de proporcionar claridad y objetividad en la identificación de ese diagnóstico de enfermeríaOBJECTIVES: To characterize the scientific articles related to the NANDA-I nursing diagnosis, decreased cardiac output. Verify those articles that describe the behavior of the defining characteristics of this diagnosis, identifying those that occur with the highest frequency. METHODS: A systematic review of literature published between the years 1985 - 2008 was conducted, using the following databases: Lilacs, SciELO, EMBASE, Medline, Pubmed and Cochrane. RESULTS: The sample included 13 articles which identified 50 defining characteristics. Ten characteristics were noted to occur with high frequency: altered heart rate/rhythm, dyspnea, labile blood pressure, rales, oliguria / anuria, edema, cold skin, fatigue / weakness, decreased peripheral pulses and decreased peripheral perfusion. CONCLUSION: This subject has not been explored in depth in the literature. The importance of physical examination, the use of less invasive techniques, and the need to review the proposed defining characteristics to provide clarity and objectivity in the identification of this nursing diagnosis was identified

  17. Redesign lifts prep output 288%

    Energy Technology Data Exchange (ETDEWEB)

    Hamric, J

    1987-02-01

    This paper outlines the application of engineering creativity and how it brought output at an Ohio coal preparation plant up from 12,500 tpd to nearly four times that figure, 48,610 tpd. By streamlining the conveyor systems, removing surplus belt length and repositioning subplants the whole operation was able to run far more efficiently with a greater output. Various other alterations including the raw material supply and management and operating practices were also undertaken to provide a test for the achievements possible with such reorganization. The new developments have been in the following fields: fine coal cleaning, heavy media cyclones, feeders, bins, filter presses, dewatering equipment and settling tanks. Output is now limited only by the reduced demand by the Gavin power station nearby.

  18. Output factors and scatter ratios

    Energy Technology Data Exchange (ETDEWEB)

    Shrivastava, P N; Summers, R E; Samulski, T V; Baird, L C [Allegheny General Hospital, Pittsburgh, PA (USA); Ahuja, A S; Dubuque, G L; Hendee, W R; Chhabra, A S

    1979-07-01

    Reference is made to a previous publication on output factors and scatter ratios for radiotherapy units in which it was suggested that the output factor should be included in the definitions of scatter-air ratio and tissue-maximum ratio. In the present correspondence from other authors and from the authors of the previous publication, the original definitions and the proposed changes are discussed. Radiation scatter from source and collimator degradation of beam energy and calculation of dose in tissue are considered in relation to the objective of accurate dosimetry.

  19. Long-Term Monitoring of Physical Behavior Reveals Different Cardiac Responses to Physical Activity among Subjects with and without Chronic Neck Pain

    Directory of Open Access Journals (Sweden)

    David M. Hallman

    2015-01-01

    Full Text Available Background. We determined the extent to which heart rate variability (HRV responses to daily physical activity differ between subjects with and without chronic neck pain. Method. Twenty-nine subjects (13 women with chronic neck pain and 27 age- and gender-matched healthy controls participated. Physical activity (accelerometry, HRV (heart rate monitor, and spatial location (Global Positioning System (GPS were recorded for 74 hours. GPS data were combined with a diary to identify periods of work and of leisure at home and elsewhere. Time- and frequency-domain HRV indices were calculated and stratified by period and activity type (lying/sitting, standing, or walking. ANCOVAs with multiple adjustments were used to disclose possible group differences in HRV. Results. The pain group showed a reduced HRV response to physical activity compared with controls (p=.001, according to the sympathetic-baroreceptor HRV index (LF/HF, ratio between low- and high-frequency power, even after adjustment for leisure time physical activity, work stress, sleep quality, mental health, and aerobic capacity (p=.02. The parasympathetic response to physical activity did not differ between groups. Conclusions. Relying on long-term monitoring of physical behavior and heart rate variability, we found an aberrant sympathetic-baroreceptor response to daily physical activity among subjects with chronic neck pain.

  20. Long-Term Monitoring of Physical Behavior Reveals Different Cardiac Responses to Physical Activity among Subjects with and without Chronic Neck Pain

    Science.gov (United States)

    Hallman, David M.; Mathiassen, Svend Erik; Lyskov, Eugene

    2015-01-01

    Background. We determined the extent to which heart rate variability (HRV) responses to daily physical activity differ between subjects with and without chronic neck pain. Method. Twenty-nine subjects (13 women) with chronic neck pain and 27 age- and gender-matched healthy controls participated. Physical activity (accelerometry), HRV (heart rate monitor), and spatial location (Global Positioning System (GPS)) were recorded for 74 hours. GPS data were combined with a diary to identify periods of work and of leisure at home and elsewhere. Time- and frequency-domain HRV indices were calculated and stratified by period and activity type (lying/sitting, standing, or walking). ANCOVAs with multiple adjustments were used to disclose possible group differences in HRV. Results. The pain group showed a reduced HRV response to physical activity compared with controls (p = .001), according to the sympathetic-baroreceptor HRV index (LF/HF, ratio between low- and high-frequency power), even after adjustment for leisure time physical activity, work stress, sleep quality, mental health, and aerobic capacity (p = .02). The parasympathetic response to physical activity did not differ between groups. Conclusions. Relying on long-term monitoring of physical behavior and heart rate variability, we found an aberrant sympathetic-baroreceptor response to daily physical activity among subjects with chronic neck pain. PMID:26557711

  1. Application of transpulmonary thermodilution monitoring (PiCCO) in patient with neurogenic pulmonary edema and acute obstructive hydrocephalus due to a central neurocytoma: A case report

    OpenAIRE

    Ryoichi Iwata; Kunikazu Yoshimura; Yoko Fujita; Tatsuo Uesaka; Hideyuki Oshige; Akio Asai

    2017-01-01

    Neurogenic pulmonary edema (NPE) is an acute life-threatening complication associated with many forms of central nervous system injury. Its pathophysiology is still debated. We report a patient with acute obstructive hydrocephalus due to a central neurocytoma who also had NPE, for which serial transpulmonary thermodilution monitoring (PiCCO) was performed. Insertion of the PiCCO, which provides information about the patient's cardiac output, preload status and amount of lung water, revealed a...

  2. Physiologic stress interventions in cardiac imaging

    International Nuclear Information System (INIS)

    Buda, A.J.

    1985-01-01

    Physiologic stress interventions are designed to assess the reserve capability of coronary flow and myocardial function. In the normal individual, a sufficiently intense physiologic stress may increase coronary flow and cardiac output by 500% to 600%. However, in patients with cardiac disease, these reserve responses may be absent, or considerably blunted. Thus, physiologic stress testing has proved extremely helpful in detecting cardiac abnormalities when resting cardiac function appears normal. Although dynamic exercise remains the standard approach to physiologic stress testing, a number of other interventions have been used, including: (1) isometric exercise, (2) atrial pacing, (3) cold pressor testing, (4) postextrasystolic potentiation, (5) volume loading, and (6) negative intrathoracic pressure. Each of these may be considered an alternative physiologic intervention whenever dynamic exercise is not feasible. These alternative approaches are important since, in our experience, 20% to 30% of subjects are unable to perform dynamic exercise, or exercise inadequately to produce a sufficiently intense cardiac stress. This chapter reviews physiologic considerations, indications, contraindications, protocols, and results of these physiologic stress interventions when used in combination with cardiac radionuclide procedures

  3. World Input-Output Network.

    Directory of Open Access Journals (Sweden)

    Federica Cerina

    Full Text Available Production systems, traditionally analyzed as almost independent national systems, are increasingly connected on a global scale. Only recently becoming available, the World Input-Output Database (WIOD is one of the first efforts to construct the global multi-regional input-output (GMRIO tables. By viewing the world input-output system as an interdependent network where the nodes are the individual industries in different economies and the edges are the monetary goods flows between industries, we analyze respectively the global, regional, and local network properties of the so-called world input-output network (WION and document its evolution over time. At global level, we find that the industries are highly but asymmetrically connected, which implies that micro shocks can lead to macro fluctuations. At regional level, we find that the world production is still operated nationally or at most regionally as the communities detected are either individual economies or geographically well defined regions. Finally, at local level, for each industry we compare the network-based measures with the traditional methods of backward linkages. We find that the network-based measures such as PageRank centrality and community coreness measure can give valuable insights into identifying the key industries.

  4. Remote input/output station

    CERN Multimedia

    1972-01-01

    A general view of the remote input/output station installed in building 112 (ISR) and used for submitting jobs to the CDC 6500 and 6600. The card reader on the left and the line printer on the right are operated by programmers on a self-service basis.

  5. Compact Circuit Preprocesses Accelerometer Output

    Science.gov (United States)

    Bozeman, Richard J., Jr.

    1993-01-01

    Compact electronic circuit transfers dc power to, and preprocesses ac output of, accelerometer and associated preamplifier. Incorporated into accelerometer case during initial fabrication or retrofit onto commercial accelerometer. Made of commercial integrated circuits and other conventional components; made smaller by use of micrologic and surface-mount technology.

  6. CARDIAC FUNCTION AND IRON CHELATION IN THALASSEMIA MAJOR AND INTERMEDIA: A REVIEW OF THE UNDERLYING PATHOPHYSIOLOGY AND APPROACH TO CHELATION MANAGEMENT

    Directory of Open Access Journals (Sweden)

    Athanasios Aessopos

    2009-07-01

    Full Text Available Heart disease is the leading cause of mortality and one of the main causes of morbidity in beta-thalassemia. Patients with homozygous thalassemia may have either a severe phenotype which is usually transfusion dependent or a milder form that is thalassemia intermedia.  The two main factors that determine cardiac disease in homozygous β thalassemia are the high output state that results from chronic tissue hypoxia, hypoxia-induced compensatory reactions and iron overload.  The high output state playing a major role in thalassaemia intermedia and the iron load being more significant in the major form. Arrhythmias, vascular involvement that leads to an increased pulmonary vascular resistance and an increased systemic vascular stiffness and valvular abnormalities also contribute to the cardiac dysfunction in varying degrees according to the severity of the phenotype.  Endocrine abnormalities, infections, renal function and medications can also play a role in the overall cardiac function.  For thalassaemia major, regular and adequate blood transfusions and iron chelation therapy are the mainstays of management. The approach to thalassaemia intermedia, today, is aimed at monitoring for complications and initiating, timely, regular transfusions and/or iron chelation therapy.  Once the patients are on transfusions, then they should be managed in the same way as the thalassaemia major patients.  If cardiac manifestations of dysfunction are present in either form of thalassaemia, high pre transfusion Hb levels need to be maintained in order to reduce cardiac output and appropriate intensive chelation therapy needs to be instituted.  In general recommendations on chelation, today, are usually made according to the Cardiac Magnetic Resonance findings, if available.  With the advances in the latter technology and the ability to tailor chelation therapy according to the MRI findings as well as the availability of three iron chelators, together with

  7. Cardiac contractility, central haemodynamics and blood pressure regulation during semistarvation

    DEFF Research Database (Denmark)

    Stokholm, K H; Breum, L; Astrup, A

    1991-01-01

    pressure (BP) declined. The fall in BP was caused by the reduction in cardiac output as the total peripheral resistance was unchanged. Finally, the decline in total blood volume was not significant. These findings together with a reduction in heart rate indicated that a reduced sympathetic tone via......Eight obese patients were studied before and after 2 weeks of treatment by a very-low-calorie diet (VLCD). Cardiac output and central blood volume (pulmonary blood volume and left atrial volume) were determined by indicator dilution (125I-albumin) and radionuclide angiocardiography (first pass...... and equilibrium technique by [99Tcm]red blood cells). Cardiac output decreased concomitantly with the reduction in oxygen uptake as the calculated systemic arteriovenous difference of oxygen was unaltered. There were no significant decreases in left ventricular contractility indices, i.e. the ejection fraction...

  8. Relationship between cardiac function and resting cerebral blood flow: MRI measurements in healthy elderly subjects.

    Science.gov (United States)

    Henriksen, Otto M; Jensen, Lars T; Krabbe, Katja; Larsson, Henrik B W; Rostrup, Egill

    2014-11-01

    Although both impaired cardiac function and reduced cerebral blood flow are associated with ageing, current knowledge of the influence of cardiac function on resting cerebral blood flow (CBF) is limited. The aim of this study was to investigate the potential effects of cardiac function on CBF. CBF and cardiac output were measured in 31 healthy subjects 50-75 years old using magnetic resonance imaging techniques. Mean values of CBF, cardiac output and cardiac index were 43.6 ml per 100 g min(-1), 5.5 l min(-1) and 2.7 l min(-1) m(-2), respectively, in males, and 53.4 ml per 100 g min(-1), 4.3 l min(-1) and 2.4 l min(-1) m(-2), respectively, in females. No effects of cardiac output or cardiac index on CBF or structural signs of brain ageing were observed. However, fractional brain flow defined as the ratio of total brain flow to cardiac output was inversely correlated with cardiac index (r(2) = 0.22, P = 0.008) and furthermore lower in males than in females (8.6% versus 12.5%, P = 0.003). Fractional brain flow was also inversely correlated with cerebral white matter lesion grade, although this effect was not significant when adjusted for age. Frequency analysis of heart rate variability showed a gender-related inverse association of increased low-to-high-frequency power ratio with CBF and fractional brain flow. The findings do not support a direct effect of cardiac function on CBF, but demonstrates gender-related differences in cardiac output distribution. We propose fractional brain flow as a novel index that may be a useful marker of adequate brain perfusion in the context of ageing as well as cardiovascular disease. © 2013 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  9. Diffuse infiltrative cardiac tuberculosis

    International Nuclear Information System (INIS)

    Gulati, Gurpreet S; Kothari, Shyam S

    2011-01-01

    We present the cardiac magnetic resonance images of an unusual form of cardiac tuberculosis. Nodular masses in a sheet-like distribution were seen to infiltrate the outer myocardium and pericardium along most of the cardiac chambers. The lesions showed significant resolution on antitubercular therapy

  10. UFO - The Universal FEYNRULES Output

    Science.gov (United States)

    Degrande, Céline; Duhr, Claude; Fuks, Benjamin; Grellscheid, David; Mattelaer, Olivier; Reiter, Thomas

    2012-06-01

    We present a new model format for automatized matrix-element generators, the so-called Universal FEYNRULES Output (UFO). The format is universal in the sense that it features compatibility with more than one single generator and is designed to be flexible, modular and agnostic of any assumption such as the number of particles or the color and Lorentz structures appearing in the interaction vertices. Unlike other model formats where text files need to be parsed, the information on the model is encoded into a PYTHON module that can easily be linked to other computer codes. We then describe an interface for the MATHEMATICA package FEYNRULES that allows for an automatic output of models in the UFO format.

  11. Aggregate Supply and Potential Output

    OpenAIRE

    Razin, Assaf

    2004-01-01

    The New-Keynesian aggregate supply derives from micro-foundations an inflation-dynamics model very much like the tradition in the monetary literature. Inflation is primarily affected by: (i) economic slack; (ii) expectations; (iii) supply shocks; and (iv) inflation persistence. This paper extends the New Keynesian aggregate supply relationship to include also fluctuations in potential output, as an additional determinant of the relationship. Implications for monetary rules and to the estimati...

  12. Monitoring the quality of cardiac surgery based on three or more surgical outcomes using a new variable life-adjusted display.

    Science.gov (United States)

    Gan, Fah Fatt; Tang, Xu; Zhu, Yexin; Lim, Puay Weng

    2017-06-01

    The traditional variable life-adjusted display (VLAD) is a graphical display of the difference between expected and actual cumulative deaths. The VLAD assumes binary outcomes: death within 30 days of an operation or survival beyond 30 days. Full recovery and bedridden for life, for example, are considered the same outcome. This binary classification results in a great loss of information. Although there are many grades of survival, the binary outcomes are commonly used to classify surgical outcomes. Consequently, quality monitoring procedures are developed based on binary outcomes. With a more refined set of outcomes, the sensitivities of these procedures can be expected to improve. A likelihood ratio method is used to define a penalty-reward scoring system based on three or more surgical outcomes for the new VLAD. The likelihood ratio statistic W is based on testing the odds ratio of cumulative probabilities of recovery R. Two methods of implementing the new VLAD are proposed. We accumulate the statistic W-W¯R to estimate the performance of a surgeon where W¯R is the average of the W's of a historical data set. The accumulated sum will be zero based on the historical data set. This ensures that if a new VLAD is plotted for a future surgeon of performance similar to this average performance, the plot will exhibit a horizontal trend. For illustration of the new VLAD, we consider 3-outcome surgical results: death within 30 days, partial and full recoveries. In our first illustration, we show the effect of partial recoveries on surgical results of a surgeon. In our second and third illustrations, the surgical results of two surgeons are compared using both the traditional VLAD based on binary-outcome data and the new VLAD based on 3-outcome data. A reversal in relative performance of surgeons is observed when the new VLAD is used. In our final illustration, we display the surgical results of four surgeons using the new VLAD based completely on 3-outcome data. Full

  13. Crisis management during anaesthesia: cardiac arrest.

    Science.gov (United States)

    Runciman, W B; Morris, R W; Watterson, L M; Williamson, J A; Paix, A D

    2005-06-01

    Cardiac arrest attributable to anaesthesia occurs at the rate of between 0.5 and 1 case per 10 000 cases, tends to have a different profile to that of cardiac arrest occurring elsewhere, and has an in-hospital mortality of 20%. However, as individual practitioners encounter cardiac arrest rarely, the rapidity with which the diagnosis is made and the consistency of appropriate management varies considerably. To examine the role of a previously described core algorithm "COVER ABCD-A SWIFT CHECK", supplemented by a sub-algorithm for cardiac arrest, in the management of cardiac arrest occurring in association with anaesthesia. The potential performance of this structured approach for each the relevant incidents among the first 4000 reported to the Australian Incident Monitoring Study (AIMS) was compared with the actual management as reported by the anaesthetists involved. There were 129 reports of cardiac arrest associated with anaesthesia among the first 4000 AIMS incident reports. Identified aetiological factors were grouped into five categories: (1) anaesthetic technique (11 cases with this category alone; 32 with this and one or more of the other categories, representing 25% of all 129 cardiac arrests); (2) drug related (16; 32, 25%); (3) associated with surgical procedure (9; 29, 22%); (4) associated with pre-existing medical or surgical disease (30; 82, 64%); (5) unknown (8; 14, 11%). The "real life" presentation and management of cardiac arrest in association with anaesthesia differs substantially from that detailed in general published guidelines. Cardiac rhythms at the time were sinus bradycardia (23%); asystole (22%); tachycardia/ventricular tachycardia/ventricular fibrillation (14%); and normal (7%), with a further third unknown. Details of treatment were recorded in 110 reports; modalities employed included cardiac compression (72%); adrenaline (61%); 100% oxygen (58%); atropine (38%); intravenous fluids (25%), and electrical defibrillation (17%). There

  14. Roles of PDE1 in Pathological Cardiac Remodeling and Dysfunction.

    Science.gov (United States)

    Chen, Si; Knight, Walter E; Yan, Chen

    2018-04-23

    Pathological cardiac hypertrophy and dysfunction is a response to various stress stimuli and can result in reduced cardiac output and heart failure. Cyclic nucleotide signaling regulates several cardiac functions including contractility, remodeling, and fibrosis. Cyclic nucleotide phosphodiesterases (PDEs), by catalyzing the hydrolysis of cyclic nucleotides, are critical in the homeostasis of intracellular cyclic nucleotide signaling and hold great therapeutic potential as drug targets. Recent studies have revealed that the inhibition of the PDE family member PDE1 plays a protective role in pathological cardiac remodeling and dysfunction by the modulation of distinct cyclic nucleotide signaling pathways. This review summarizes recent key findings regarding the roles of PDE1 in the cardiac system that can lead to a better understanding of its therapeutic potential.

  15. The outcome of anaesthesia related cardiac arrest in a

    Directory of Open Access Journals (Sweden)

    O.O. Adekola

    2016-07-01

    Conclusion: Anaesthesia related cardiac arrest and mortality were linked to cardiovascular depression from halothane overdose in our institution. The burden can be reduced by improving on establishing standard monitoring in the perioperative period, and a team approach to patients care.

  16. Robotic cardiac surgery: an anaesthetic challenge.

    Science.gov (United States)

    Wang, Gang; Gao, Changqing

    2014-08-01

    Robotic cardiac surgery with the da Vinci robotic surgical system offers the benefits of a minimally invasive procedure, including a smaller incision and scar, reduced risk of infection, less pain and trauma, less bleeding and blood transfusion requirements, shorter hospital stay and decreased recovery time. Robotic cardiac surgery includes extracardiac and intracardiac procedures. Extracardiac procedures are often performed on a beating heart. Intracardiac procedures require the aid of peripheral cardiopulmonary bypass via a minithoracotomy. Robotic cardiac surgery, however, poses challenges to the anaesthetist, as the obligatory one-lung ventilation (OLV) and CO2 insufflation may reduce cardiac output and increase pulmonary vascular resistance, potentially resulting in hypoxaemia and haemodynamic compromise. In addition, surgery requires appropriate positioning of specialised cannulae such as an endopulmonary vent, endocoronary sinus catheter, and endoaortic clamp catheter under the guidance of transoesophageal echocardiography. Therefore, cardiac anaesthetists should have a working knowledge of these systems, OLV and haemodynamic support. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  17. Judicial Influence on Policy Outputs?

    DEFF Research Database (Denmark)

    Martinsen, Dorte Sindbjerg

    2015-01-01

    to override unwanted jurisprudence. In this debate, the Court of Justice of the European Union (CJEU) has become famous for its central and occasionally controversial role in European integration. This article examines to what extent and under which conditions judicial decisions influence European Union (EU......) social policy outputs. A taxonomy of judicial influence is constructed, and expectations of institutional and political conditions on judicial influence are presented. The analysis draws on an extensive novel data set and examines judicial influence on EU social policies over time, that is, between 1958...

  18. [Pressure sensors to prevent cardiac decompensation].

    Science.gov (United States)

    Klug, Didier

    2017-11-01

    Most cases of hospitalisation for heart failure are preceded by episodes of cardiac decompensation. Preventing these episodes would improve quality of life and reduce mortality and treatment costs. The monitoring of intracardiac pressures, using innovative sensors, coupled with telemedicine, offers interesting perspectives. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  19. An integrated bioimpedance—ECG gating technique for respiratory and cardiac motion compensation in cardiac PET

    International Nuclear Information System (INIS)

    Koivumäki, Tuomas; Nekolla, Stephan G; Fürst, Sebastian; Loher, Simone; Schwaiger, Markus; Vauhkonen, Marko; Hakulinen, Mikko A

    2014-01-01

    Respiratory motion may degrade image quality in cardiac PET imaging. Since cardiac PET studies often involve cardiac gating by ECG, a separate respiratory monitoring system is required increasing the logistic complexity of the examination, in case respiratory gating is also needed. Thus, we investigated the simultaneous acquisition of both respiratory and cardiac gating signals using II limb lead mimicking electrode configuration during cardiac PET scans of 11 patients. In addition to conventional static and ECG-gated images, bioimpedance technique was utilized to generate respiratory- and dual-gated images. The ability of the bioimpedance technique to monitor intrathoracic respiratory motion was assessed estimating cardiac displacement between end-inspiration and -expiration. The relevance of dual gating was evaluated in left ventricular volume and myocardial wall thickness measurements. An average 7.6  ±  3.3 mm respiratory motion was observed in the study population. Dual gating showed a small but significant increase (4 ml, p = 0.042) in left ventricular myocardial volume compared to plain cardiac gating. In addition, a thinner myocardial wall was observed in dual-gated images (9.3  ±  1.3 mm) compared to cardiac-gated images (11.3  ±  1.3 mm, p = 0.003). This study shows the feasibility of bioimpedance measurements for dual gating in a clinical setting. The method enables simultaneous acquisition of respiratory and cardiac gating signals using a single device with standard ECG electrodes. (paper)

  20. Bigger is not better: cortisol-induced cardiac growth and dysfunction in salmonids

    DEFF Research Database (Denmark)

    Johansen, Ida B.; Sandblom, Erik; Skov, Peter Vilhelm

    2017-01-01

    show that rainbow trout (Oncorhynchus mykiss) treated with cortisol in the diet for 45 days have enlarged hearts with lower maximum stroke volume and cardiac output. In accordance with impaired cardiac performance, overall circulatory oxygen-transporting capacity was diminished as indicated by reduced...

  1. Comparação dos efeitos da dobutamina e da milrinona sobre a hemodinâmica e o transporte de oxigênio em pacientes submetidos à cirurgia cardíaca com baixo débito cardíaco após indução anestésica Comparación de los efectos de la dobutamina y de la milrinona sobre la hemodinámica y el transporte de oxígeno en pacientes sometidos a cirugía cardiaca con bajo débito cardiaco después de inducción anestésica Comparison of the effects of dobutamine and milrinone on hemodynamic parameters and oxygen supply in patients undergoing cardiac surgery with low cardiac output after anesthetic induction

    Directory of Open Access Journals (Sweden)

    Maria José Carvalho Carmona

    2010-06-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: Diversas classes de fármacos inotrópicos, com efeitos hemodinâmicos diferentes, são utilizadas no tratamento do baixo débito cardíaco em pacientes com disfunção sistólica submetidos a procedimento cirúrgico cardíaco. O objetivo deste estudo foi comparar o efeito da dobutamina e da milrinona sobre a hemodinâmica e o transporte de oxigênio nessa população de pacientes. MÉTODO: Após aprovação do Comitê de Ética institucional e obtenção do consentimento escrito pós-informado, 20 pacientes submetidos à cirurgia cardíaca e com índice cardíaco JUSTIFICATIVA Y OBJETIVOS: Diversas clases de fármacos inotrópicos con efectos hemodinámicos diferentes, se usan en el tratamiento del bajo débito cardíaco en pacientes con disfunción sistólica sometidos al procedimiento quirúrgico cardíaco. El objetivo de este estudio, fue comparar el efecto de la dobutamina y de la milrinona sobre la hemodinámica y el transporte de oxígeno en esa población de pacientes. MÉTODO: Después de la aprobación del Comité de Ética institucional y de la obtención del consentimiento informado, 20 pacientes sometidos a la cirugía cardíaca y con índice cardíaco BACKGROUND AND OBJECTIVES: Several classes of inotropic drugs with different hemodynamic effects are used in the treatment of low cardiac output in patients with diastolic dysfunction undergoing cardiac surgery. The objective of the present study was to compare the effects of dobutamine and milrinone on hemodynamic parameters and oxygen supply in this population of patients. METHODS: After approval by the Ethics Committee of the institution and signing of the informed consent, 20 patients undergoing cardiac surgery with cardiac index < 2 L.min-1.m2 after anesthetic induction and place ment of a pulmonary artery catheter were randomly divided to receive dobutamine 5 µg.kg-1. min-1 (n = 10, or milrinone 0.5 µg.kg-1.min-1 (n = 10. Hemodynamic parameters were

  2. Stimulating endogenous cardiac regeneration

    Directory of Open Access Journals (Sweden)

    Amanda eFinan

    2015-09-01

    Full Text Available The healthy adult heart has a low turnover of cardiac myocytes. The renewal capacity, however, is augmented after cardiac injury. Participants in cardiac regeneration include cardiac myocytes themselves, cardiac progenitor cells, and peripheral stem cells, particularly from the bone marrow compartment. Cardiac progenitor cells and bone marrow stem cells are augmented after cardiac injury, migrate to the myocardium, and support regeneration. Depletion studies of these populations have demonstrated their necessary role in cardiac repair. However, the potential of these cells to completely regenerate the heart is limited. Efforts are now being focused on ways to augment these natural pathways to improve cardiac healing, primarily after ischemic injury but in other cardiac pathologies as well. Cell and gene therapy or pharmacological interventions are proposed mechanisms. Cell therapy has demonstrated modest results and has passed into clinical trials. However, the beneficial effects of cell therapy have primarily been their ability to produce paracrine effects on the cardiac tissue and recruit endogenous stem cell populations as opposed to direct cardiac regeneration. Gene therapy efforts have focused on prolonging or reactivating natural signaling pathways. Positive results have been demonstrated to activate the endogenous stem cell populations and are currently being tested in clinical trials. A potential new avenue may be to refine pharmacological treatments that are currently in place in the clinic. Evidence is mounting that drugs such as statins or beta blockers may alter endogenous stem cell activity. Understanding the effects of these drugs on stem cell repair while keeping in mind their primary function may strike a balance in myocardial healing. To maximize endogenous cardiac regeneration,a combination of these approaches couldameliorate the overall repair process to incorporate the participation ofmultiple cell players.

  3. Characterization of Glutamatergic Neurons in the Rat Atrial Intrinsic Cardiac Ganglia that Project to the Cardiac Ventricular Wall

    Science.gov (United States)

    Wang, Ting; Miller, Kenneth E.

    2016-01-01

    The intrinsic cardiac nervous system modulates cardiac function by acting as an integration site for regulating autonomic efferent cardiac output. This intrinsic system is proposed to be composed of a short cardio-cardiac feedback control loop within the cardiac innervation hierarchy. For example, electrophysiological studies have postulated the presence of sensory neurons in intrinsic cardiac ganglia for regional cardiac control. There is still a knowledge gap, however, about the anatomical location and neurochemical phenotype of sensory neurons inside intrinsic cardiac ganglia. In the present study, rat intrinsic cardiac ganglia neurons were characterized neurochemically with immunohistochemistry using glutamatergic markers: vesicular glutamate transporters 1 and 2 (VGLUT1; VGLUT2), and glutaminase (GLS), the enzyme essential for glutamate production. Glutamatergic neurons (VGLUT1/VGLUT2/GLS) in the ICG that have axons to the ventricles were identified by retrograde tracing of wheat germ agglutinin-horseradish peroxidase (WGA-HRP) injected in the ventricular wall. Co-labeling of VGLUT1, VGLUT2, and GLS with the vesicular acetylcholine transporter (VAChT) was used to evaluate the relationship between post-ganglionic autonomic neurons and glutamatergic neurons. Sequential labeling of VGLUT1 and VGLUT2 in adjacent tissue sections was used to evaluate the co-localization of VGLUT1 and VGLUT2 in ICG neurons. Our studies yielded the following results: (1) intrinsic cardiac ganglia contain glutamatergic neurons with GLS for glutamate production and VGLUT1 and 2 for transport of glutamate into synaptic vesicles; (2) atrial intrinsic cardiac ganglia contain neurons that project to ventricle walls and these neurons are glutamatergic; (3) many glutamatergic ICG neurons also were cholinergic, expressing VAChT. (4) VGLUT1 and VGLUT2 co-localization occurred in ICG neurons with variation of their protein expression level. Investigation of both glutamatergic and cholinergic ICG

  4. Integration of TMVA Output into Jupyter notebooks

    CERN Document Server

    Saliji, Albulena

    2016-01-01

    The purpose of this report is to describe the work that I have been doing during these past eight weeks as a Summer Student at CERN. The task which was assigned to me had to do with the integration of TMVA Output into Jupyter notebooks. In order to integrate the TMVA Output into the Jupyter notebook, first, improvement of the TMVA Output in the terminal was required. Once the output was improved, it needed to be transformed into HTML output and at the end it would be possible to integrate that output into the Jupyter notebook.

  5. Cardiac function and myocardial perfusion immediately following maximal treadmill exercise inside the MRI room

    Directory of Open Access Journals (Sweden)

    Ballinger Michelle R

    2008-01-01

    Full Text Available Abstract Treadmill exercise stress testing is an essential tool in the prevention, detection, and treatment of a broad spectrum of cardiovascular disease. After maximal exercise, cardiac images at peak stress are typically acquired using nuclear scintigraphy or echocardiography, both of which have inherent limitations. Although CMR offers superior image quality, the lack of MRI-compatible exercise and monitoring equipment has prevented the realization of treadmill exercise CMR. It is critical to commence imaging as quickly as possible after exercise to capture exercise-induced cardiac wall motion abnormalities. We modified a commercial treadmill such that it could be safely positioned inside the MRI room to minimize the distance between the treadmill and the scan table. We optimized the treadmill exercise CMR protocol in 20 healthy volunteers and successfully imaged cardiac function and myocardial perfusion at peak stress, followed by viability imaging at rest. Imaging commenced an average of 30 seconds after maximal exercise. Real-time cine of seven slices with no breath-hold and no ECG-gating was completed within 45 seconds of exercise, immediately followed by stress perfusion imaging of three short-axis slices which showed an average time to peak enhancement within 57 seconds of exercise. We observed a 3.1-fold increase in cardiac output and a myocardial perfusion reserve index of 1.9, which agree with reported values for healthy subjects at peak stress. This study successfully demonstrates in-room treadmill exercise CMR in healthy volunteers, but confirmation of feasibility in patients with heart disease is still needed.

  6. Marketing cardiac CT programs.

    Science.gov (United States)

    Scott, Jason

    2010-01-01

    There are two components of cardiac CT discussed in this article: coronary artery calcium scoring (CACS) and coronary computed tomography angiography (CCTA).The distinctive advantages of each CT examination are outlined. In order to ensure a successful cardiac CT program, it is imperative that imaging facilities market their cardiac CT practices effectively in order to gain a competitive advantage in this valuable market share. If patients receive quality care by competent individuals, they are more likely to recommend the facility's cardiac CT program. Satisfied patients will also be more willing to come back for any further testing.

  7. Cardiac surgery in the parturient.

    Science.gov (United States)

    Chandrasekhar, Shobana; Cook, Christopher R; Collard, Charles D

    2009-03-01

    Heart disease is the primary cause of nonobstetric mortality in pregnancy, occurring in 1%-3% of pregnancies and accounting for 10%-15% of maternal deaths. Congenital heart disease has become more prevalent in women of childbearing age, representing an increasing percentage (up to 75%) of heart disease in pregnancy. Untreated maternal heart disease also places the fetus at risk. Independent predictors of neonatal complications include a maternal New York Heart Association heart failure classification >2, anticoagulation use during pregnancy, smoking, multiple gestation, and left heart obstruction. Because cardiac surgical morbidity and mortality in the parturient is higher than nonpregnant patients, most parturients with cardiac disease are first managed medically, with cardiac surgery being reserved when medical management fails. Risk factors for maternal mortality during cardiac surgery include the use of vasoactive drugs, age, type of surgery, reoperation, and maternal functional class. Risk factors for fetal mortality include maternal age >35 yr, functional class, reoperation, emergency surgery, type of myocardial protection, and anoxic time. Nonetheless, acceptable maternal and fetal perioperative mortality rates may be achieved through such measures as early preoperative detection of maternal cardiovascular decompensation, use of fetal monitoring, delivery of a viable fetus before the operation and scheduling surgery on an elective basis during the second trimester. Additionally, fetal morbidity may be reduced during cardiopulmonary bypass by optimizing maternal oxygen-carrying capacity and uterine blood flow. Current maternal bypass recommendations include: 1) maintaining the pump flow rate >2.5 L x min(-1) x m(-2) and perfusion pressure >70 mm Hg; 2) maintaining the hematocrit > 28%; 3) using normothermic perfusion when feasible; 4) using pulsatile flow; and 5) using alpha-stat pH management.

  8. Consumer sleep monitors: is there a baby in the bathwater?

    Science.gov (United States)

    Russo, Kathryn; Goparaju, Balaji; Bianchi, Matt T

    2015-01-01

    The rapid expansion of consumer sleep devices is outpacing the validation data necessary to assess the potential use of these devices in clinical and research settings. Common sleep monitoring devices utilize a variety of sensors to track movement as well as cardiac and respiratory physiology. The variety of sensors and user-specific factors offer the potential, at least theoretically, for clinically relevant information. We describe the current challenges for interpretation of consumer sleep monitoring data, since the devices are mainly used in non-medical contexts (consumer use) although medically-definable sleep disorders may commonly occur in this setting. A framework for addressing questions of how certain devices might be useful is offered. We suggest that multistage validation efforts are crucially needed, from the level of sensor data and algorithm output, to extrapolations beyond healthy adults and into other populations and real-world environments.

  9. Observability of linear systems with saturated outputs

    NARCIS (Netherlands)

    Koplon, R.; Sontag, E.D.; Hautus, M.L.J.

    1994-01-01

    We present necessary and sufficient conditions for observability of the class of output-saturated systems. These are linear systems whose output passes through a saturation function before it can be measured.

  10. Intrinsic cardiac nervous system in tachycardia induced heart failure.

    Science.gov (United States)

    Arora, Rakesh C; Cardinal, Rene; Smith, Frank M; Ardell, Jeffrey L; Dell'Italia, Louis J; Armour, J Andrew

    2003-11-01

    The purpose of this study was to test the hypothesis that early-stage heart failure differentially affects the intrinsic cardiac nervous system's capacity to regulate cardiac function. After 2 wk of rapid ventricular pacing in nine anesthetized canines, cardiac and right atrial neuronal function were evaluated in situ in response to enhanced cardiac sensory inputs, stimulation of extracardiac autonomic efferent neuronal inputs, and close coronary arterial administration of neurochemicals that included nicotine. Right atrial neuronal intracellular electrophysiological properties were then evaluated in vitro in response to synaptic activation and nicotine. Intrinsic cardiac nicotine-sensitive, neuronally induced cardiac responses were also evaluated in eight sham-operated, unpaced animals. Two weeks of rapid ventricular pacing reduced the cardiac index by 54%. Intrinsic cardiac neurons of paced hearts maintained their cardiac mechano- and chemosensory transduction properties in vivo. They also responded normally to sympathetic and parasympathetic preganglionic efferent neuronal inputs, as well as to locally administered alpha-or beta-adrenergic agonists or angiotensin II. The dose of nicotine needed to modify intrinsic cardiac neurons was 50 times greater in failure compared with normal preparations. That dose failed to alter monitored cardiovascular indexes in failing preparations. Phasic and accommodating neurons identified in vitro displayed altered intracellular membrane properties compared with control, including decreased membrane resistance, indicative of reduced excitability. Early-stage heart failure differentially affects the intrinsic cardiac nervous system's capacity to regulate cardiodynamics. While maintaining its capacity to transduce cardiac mechano- and chemosensory inputs, as well as inputs from extracardiac autonomic efferent neurons, intrinsic cardiac nicotine-sensitive, local-circuit neurons differentially remodel such that their capacity to

  11. The Western Denmark Cardiac Computed Tomography Registry

    DEFF Research Database (Denmark)

    Nielsen, Lene Hüche; Nørgaard, Bjarne Linde; Tilsted, Hans-Henrik

    2014-01-01

    BACKGROUND: As a subregistry to the Western Denmark Heart Registry (WDHR), the Western Denmark Cardiac Computed Tomography Registry (WDHR-CCTR) is a clinical database established in 2008 to monitor and improve the quality of cardiac computed tomography (CT) in Western Denmark. OBJECTIVE: We...... examined the content, data quality, and research potential of the WDHR-CCTR. METHODS: We retrieved 2008-2012 data to examine the 1) content; 2) completeness of procedure registration using the Danish National Patient Registry as reference; 3) completeness of variable registration comparing observed vs...

  12. Diagnosis of traumatic cardiac contusion

    International Nuclear Information System (INIS)

    Waxman, K.; Soliman, M.H.; Braunstein, P.; Formosa, P.; Cohen, A.J.; Matsuura, P.; Mason, G.R.

    1986-01-01

    Cardiac contusion following blunt chest trauma remains a diagnostic problem because of a lack of sensitive diagnostic tests. This study evaluated thallous chloride Tl 201 single-photon-emission computed tomography in a series of 48 patients following blunt chest trauma. Of the 48 patients, 23 had normal scans. None of these patients proved to have serious arrhythmias during three days of continuous monitoring. Of 25 patients with abnormal or ambiguous studies, five (20%) developed serious arrhythmias requiring therapy. Single-photon-emission computed tomography scanning thus was sensitive in indicating that group of patients at risk of serious arrhythmias, and may therefore prove to be a useful screening test to determine the need for hospitalization and arrhythmia monitoring following blunt chest trauma

  13. Traction force microscopy of engineered cardiac tissues.

    Science.gov (United States)

    Pasqualini, Francesco Silvio; Agarwal, Ashutosh; O'Connor, Blakely Bussie; Liu, Qihan; Sheehy, Sean P; Parker, Kevin Kit

    2018-01-01

    Cardiac tissue development and pathology have been shown to depend sensitively on microenvironmental mechanical factors, such as extracellular matrix stiffness, in both in vivo and in vitro systems. We present a novel quantitative approach to assess cardiac structure and function by extending the classical traction force microscopy technique to tissue-level preparations. Using this system, we investigated the relationship between contractile proficiency and metabolism in neonate rat ventricular myocytes (NRVM) cultured on gels with stiffness mimicking soft immature (1 kPa), normal healthy (13 kPa), and stiff diseased (90 kPa) cardiac microenvironments. We found that tissues engineered on the softest gels generated the least amount of stress and had the smallest work output. Conversely, cardiomyocytes in tissues engineered on healthy- and disease-mimicking gels generated significantly higher stresses, with the maximal contractile work measured in NRVM engineered on gels of normal stiffness. Interestingly, although tissues on soft gels exhibited poor stress generation and work production, their basal metabolic respiration rate was significantly more elevated than in other groups, suggesting a highly ineffective coupling between energy production and contractile work output. Our novel platform can thus be utilized to quantitatively assess the mechanotransduction pathways that initiate tissue-level structural and functional remodeling in response to substrate stiffness.

  14. Probabilistic Output Analysis by Program Manipulation

    DEFF Research Database (Denmark)

    Rosendahl, Mads; Kirkeby, Maja Hanne

    2015-01-01

    The aim of a probabilistic output analysis is to derive a probability distribution of possible output values for a program from a probability distribution of its input. We present a method for performing static output analysis, based on program transformation techniques. It generates a probability...

  15. Cardiac Catheterization (For Kids)

    Science.gov (United States)

    ... First Aid & Safety Doctors & Hospitals Videos Recipes for Kids Kids site Sitio para niños How the Body Works ... Educators Search English Español Cardiac Catheterization KidsHealth / For Kids / Cardiac Catheterization What's in this article? What Is ...

  16. Frequency of Cardiac Arrhythmias in Patients with Aluminum Phosphide Poisoning

    Directory of Open Access Journals (Sweden)

    Umair Aziz

    2015-12-01

    Full Text Available Background: Cardiac failure is the major lethal consequence of aluminum phosphide (AlP poisoning. This study was designed to determine the frequency of cardiac arrhythmias in patients with AlP poisoning. Methods: In this prospective cross-sectional study, patients with definitive history of AlP poisoning treated at emergency department of Allied Hospital Faisalabad, Faisalabad, Pakistan, from July 2013 to November 2014 were included. On admission, twelve-lead electrocardiogram (ECG was performed for all patients. During admission, all patients underwent continuous cardiac monitoring using a cardiac monitor. If an arrhythmia was suspected on the cardiac monitor, another ECG was obtained immediately.  Results: During the study period, 100 patients with AlP poisoning (63% men were treated at Allied Hospital Faisalabad. Mean age of the patients was 26.7 ± 7.9 years ranging from 16 to 54 years. Tachycardia was detected in 68 patients and bradycardia in 12 patients. Hypotension was observed in 75 patients. Eighty patients developed cardiac arrhythmia. The most frequent arrhythmia was atrial fibrillation (31% of patients followed by ventricular fibrillation (20%, ventricular tachycardia (17%, 3rd degree AV block (7% and 2nd degree AV block (5%. In total, 78 patients died, depicting a 78% mortality rate following wheat pill poisoning. Among those who died, seventy-one patients had cardiac arrhythmia. Comparison of death rate between patients with and without cardiac arrhythmia showed a significant difference (71/80 (88.8% vs. 7/20 (35%; P < 0.001.  Conclusion: Wheat pill poisoning causes a very high mortality, and circulatory collapse is the major cause of death among these patients. Most of the patients with AlP poisoning develop cardiac arrhythmias which are invariably life threatening. Early detection of cardiac disorders and proper management of arrhythmias may reduce mortalities.

  17. Model output: fact or artefact?

    Science.gov (United States)

    Melsen, Lieke

    2015-04-01

    As a third-year PhD-student, I relatively recently entered the wonderful world of scientific Hydrology. A science that has many pillars that directly impact society, for example with the prediction of hydrological extremes (both floods and drought), climate change, applications in agriculture, nature conservation, drinking water supply, etcetera. Despite its demonstrable societal relevance, hydrology is often seen as a science between two stools. Like Klemeš (1986) stated: "By their academic background, hydrologists are foresters, geographers, electrical engineers, geologists, system analysts, physicists, mathematicians, botanists, and most often civil engineers." Sometimes it seems that the engineering genes are still present in current hydrological sciences, and this results in pragmatic rather than scientific approaches for some of the current problems and challenges we have in hydrology. Here, I refer to the uncertainty in hydrological modelling that is often neglected. For over thirty years, uncertainty in hydrological models has been extensively discussed and studied. But it is not difficult to find peer-reviewed articles in which it is implicitly assumed that model simulations represent the truth rather than a conceptualization of reality. For instance in trend studies, where data is extrapolated 100 years ahead. Of course one can use different forcing datasets to estimate the uncertainty of the input data, but how to prevent that the output is not a model artefact, caused by the model structure? Or how about impact studies, e.g. of a dam impacting river flow. Measurements are often available for the period after dam construction, so models are used to simulate river flow before dam construction. Both are compared in order to qualify the effect of the dam. But on what basis can we tell that the model tells us the truth? Model validation is common nowadays, but validation only (comparing observations with model output) is not sufficient to assume that a

  18. Canada's helium output rising fast

    Energy Technology Data Exchange (ETDEWEB)

    1966-12-01

    About 12 months from now, International Helium Limited will be almost ready to start up Canada's second helium extraction plant at Mankota, in Saskatchewan's Wood Mountain area about 100 miles southwest of Moose Jaw. Another 80 miles north is Saskatchewan's (and Canada's) first helium plant, operated by Canadian Helium and sitting on a gas deposit at Wilhelm, 9 miles north of Swift Current. It contains almost 2% helium, some COD2U, and the rest nitrogen. One year in production was apparently enough to convince Canadian Helium that the export market (it sells most of its helium in W. Europe) can take a lot more than it's getting. Construction began this summer on an addition to the Swift Current plant that will raise its capacity from 12 to 36MMcf per yr when it goes on stream next spring. Six months later, International Helium's 40 MMcf per yr plant to be located about 4 miles from its 2 Wood Mountain wells will double Canada's helium output again.

  19. Sudden cardiac death

    Directory of Open Access Journals (Sweden)

    Neeraj Parakh

    2015-01-01

    Full Text Available Sudden cardiac death is one of the most common cause of mortality worldwide. Despite significant advances in the medical science, there is little improvement in the sudden cardiac death related mortality. Coronary artery disease is the most common etiology behind sudden cardiac death, in the above 40 years population. Even in the apparently healthy population, there is a small percentage of patients dying from sudden cardiac death. Given the large denominator, this small percentage contributes to the largest burden of sudden cardiac death. Identification of this at risk group among the apparently healthy individual is a great challenge for the medical fraternity. This article looks into the causes and methods of preventing SCD and at some of the Indian data. Details of Brugada syndrome, Long QT syndrome, Genetics of SCD are discussed. Recent guidelines on many of these causes are summarised.

  20. CARDIAC LYMPHOMA IN DOG

    Directory of Open Access Journals (Sweden)

    G. D. Cruz

    2016-11-01

    Full Text Available Lymphoma is a lymphoid tumor that originates in hematopoietic organs such as lymph node, spleen or liver. In dogs, the overall prevalence of cardiac tumors was estimated to be only 0.19% based on the results of the survey of a large database, and lymphomas accounts for approximately 2% of all cardiac tumors. In general, the involvement of the myocardium is rarely described in canine lymphoma. Currently, there is no evidence of a viral association with primary cardiac lymphoma in dogs, but other types of immunosuppression may contribute to abnormal events, such as involvement primary cardiac. The aim of this study was to analyze a case of sudden death of a bitch, SRD, aged 10, who had the final diagnosis of cardiac lymphoma.

  1. Mathematical cardiac electrophysiology

    CERN Document Server

    Colli Franzone, Piero; Scacchi, Simone

    2014-01-01

    This book covers the main mathematical and numerical models in computational electrocardiology, ranging from microscopic membrane models of cardiac ionic channels to macroscopic bidomain, monodomain, eikonal models and cardiac source representations. These advanced multiscale and nonlinear models describe the cardiac bioelectrical activity from the cell level to the body surface and are employed in both the direct and inverse problems of electrocardiology. The book also covers advanced numerical techniques needed to efficiently carry out large-scale cardiac simulations, including time and space discretizations, decoupling and operator splitting techniques, parallel finite element solvers. These techniques are employed in 3D cardiac simulations illustrating the excitation mechanisms, the anisotropic effects on excitation and repolarization wavefronts, the morphology of electrograms in normal and pathological tissue and some reentry phenomena. The overall aim of the book is to present rigorously the mathematica...

  2. Biomaterials for cardiac regeneration

    CERN Document Server

    Ruel, Marc

    2015-01-01

    This book offers readers a comprehensive biomaterials-based approach to achieving clinically successful, functionally integrated vasculogenesis and myogenesis in the heart. Coverage is multidisciplinary, including the role of extracellular matrices in cardiac development, whole-heart tissue engineering, imaging the mechanisms and effects of biomaterial-based cardiac regeneration, and autologous bioengineered heart valves. Bringing current knowledge together into a single volume, this book provides a compendium to students and new researchers in the field and constitutes a platform to allow for future developments and collaborative approaches in biomaterials-based regenerative medicine, even beyond cardiac applications. This book also: Provides a valuable overview of the engineering of biomaterials for cardiac regeneration, including coverage of combined biomaterials and stem cells, as well as extracellular matrices Presents readers with multidisciplinary coverage of biomaterials for cardiac repair, including ...

  3. TrustGuard: A Containment Architecture with Verified Output

    Science.gov (United States)

    2017-01-01

    that the TrustGuard system has minimal performance decline, despite restrictions such as high communication latency and limited available bandwidth...design are the availability of high bandwidth and low delays between the host and the monitoring chip. 3-D integration provides an alternate way of...TRUSTGUARD: A CONTAINMENT ARCHITECTURE WITH VERIFIED OUTPUT SOUMYADEEP GHOSH A DISSERTATION PRESENTED TO THE FACULTY OF PRINCETON UNIVERSITY IN

  4. Consumer sleep monitors: is there a baby in the bathwater?

    Directory of Open Access Journals (Sweden)

    Russo K

    2015-11-01

    Full Text Available Kathryn Russo,1 Balaji Goparaju,1 Matt T Bianchi1,2 1Department of Neurology, Massachusetts General Hospital, 2Division of Sleep Medicine, Harvard Medical School, Boston, MA, USA Abstract: The rapid expansion of consumer sleep devices is outpacing the validation data necessary to assess the potential use of these devices in clinical and research settings. Common sleep monitoring devices utilize a variety of sensors to track movement as well as cardiac and respiratory physiology. The variety of sensors and user-specific factors offer the potential, at least theoretically, for clinically relevant information. We describe the current challenges for interpretation of consumer sleep monitoring data, since the devices are mainly used in nonmedical contexts (consumer use although medically-definable sleep disorders may commonly occur in this setting. A framework for addressing questions of how certain devices might be useful is offered. We suggest that multistage validation efforts are crucially needed, from the level of sensor data and algorithm output, to extrapolations beyond healthy adults and into other populations and real-world environments. Keywords: movement, cardiac and respiratory physiology, sensor, consumer sleep monitoring data

  5. PREVIMER : Meteorological inputs and outputs

    Science.gov (United States)

    Ravenel, H.; Lecornu, F.; Kerléguer, L.

    2009-09-01

    PREVIMER is a pre-operational system aiming to provide a wide range of users, from private individuals to professionals, with short-term forecasts about the coastal environment along the French coastlines bordering the English Channel, the Atlantic Ocean, and the Mediterranean Sea. Observation data and digital modelling tools first provide 48-hour (probably 96-hour by summer 2009) forecasts of sea states, currents, sea water levels and temperatures. The follow-up of an increasing number of biological parameters will, in time, complete this overview of coastal environment. Working in partnership with the French Naval Hydrographic and Oceanographic Service (Service Hydrographique et Océanographique de la Marine, SHOM), the French National Weather Service (Météo-France), the French public science and technology research institute (Institut de Recherche pour le Développement, IRD), the European Institute of Marine Studies (Institut Universitaire Européen de la Mer, IUEM) and many others, IFREMER (the French public institute fo marine research) is supplying the technologies needed to ensure this pertinent information, available daily on Internet at http://www.previmer.org, and stored at the Operational Coastal Oceanographic Data Centre. Since 2006, PREVIMER publishes the results of demonstrators assigned to limited geographic areas and to specific applications. This system remains experimental. The following topics are covered : Hydrodynamic circulation, sea states, follow-up of passive tracers, conservative or non-conservative (specifically of microbiological origin), biogeochemical state, primary production. Lastly, PREVIMER provides researchers and R&D departments with modelling tools and access to the database, in which the observation data and the modelling results are stored, to undertake environmental studies on new sites. The communication will focus on meteorological inputs to and outputs from PREVIMER. It will draw the lessons from almost 3 years during

  6. The 'icon' of output efficiency

    International Nuclear Information System (INIS)

    Bligh, L.N.; Evans, S.G.; Larcos, G.; Gruenewald, S.M.

    1999-01-01

    Full text: Output efficiency (OE) is a well-validated parameter used in the assessment of hydronephrosis. Current analysis on Microdelta appears to produce few low OE values and occasional inability to produce a result. We sought an OE program which gave a reliable response over the full range of values. The aims of this study were to determine: (1) whether OE results are comparable between two computer systems; (2) a normal range for OE on an ICON; (3) inter-observer reproducibility; and (4) the correlation between the two programs and the residual cortical activity ratio (RCA), an index which assesses tracer washout from the 20 min cortical activity/peak cortical activity. Accordingly, two blinded medical radiation scientists reviewed 41 kidneys (26 native, 15 transplant) and calculated OE for each kidney on the ICON and Microdelta computers The OE on the Microdelta and the ICON had good correspondence (r = 0.6%, SEE = 6.2). The extrapolated normal range for ICON OE was 69-92% (mean 80.9%). The inter-observer reproducibility on the ICON was excellent with a CV of 8.7%. ICON OE and RCA had a strong correlation (r = - 0.77, SEE = 0.09), compared with a weaker correlation for the Microdelta (r = 0.47, SEE = 0.13). Processing on the ICON was almost half that of the Microdelta at 4 min compared with 7 min. We conclude that OE generated by these computer programs has good correlation, an established normal range, excellent interobserver reproducibility, but differing correlation with RCA. The response of the ICON program to low ranges of OE is being investigated further

  7. Endogenous Natural Complement Inhibitor Regulates Cardiac Development

    DEFF Research Database (Denmark)

    Mortensen, Simon A; Skov, Louise L; Kjaer-Sorensen, Kasper

    2017-01-01

    mechanisms during fetal development and adult homeostasis. In this article, we describe the function of an endogenous complement inhibitor, mannan-binding lectin (MBL)-associated protein (MAp)44, in regulating the composition of a serine protease-pattern recognition receptor complex, MBL-associated serine...... of MAp44 caused impaired cardiogenesis, lowered heart rate, and decreased cardiac output. These defects were associated with aberrant neural crest cell behavior. We found that MAp44 competed with MASP-3 for pattern recognition molecule interaction, and knockdown of endogenous MAp44 expression could...... be rescued by overexpression of wild-type MAp44. Our observations provide evidence that immune molecules are centrally involved in the orchestration of cardiac tissue development....

  8. Cardiac involvement in canine babesiosis : review article

    Directory of Open Access Journals (Sweden)

    R.G. Lobetti

    2005-06-01

    Full Text Available Cardiac dysfunction in canine babesiosis has traditionally been regarded as a rare complication, with the majority of lesions reported as incidental findings at post-mortem examination. Recent studies have, however, demonstrated cardiac lesions in canine babesiosis. Cardiac troponins, especially troponin I, are sensitive markers of myocardial injury in canine babesiosis, and the magnitude of elevation of plasma troponin I concentrations appears to be proportional to the severity of the disease. ECG changes in babesiosis are similar to the pattern described for myocarditis and myocardial ischaemia and together with histopathological findings indicate that the heart suffers from the same pathological processes described in other organs in canine babesiosis, namely inflammation and hypoxia. The clinical application of the ECG appears to be limited and thus cardiovascular assessment should be based on functional monitoring rather than an ECG tracing. On cardiac histopathology from dogs that succumbed to babesiosis, haemorrhage, necrosis, inflammation and fibrin microthrombi in the myocardium were documented, all of which would have resulted in ECG changes and elevations in cardiac troponin. Myocardial damage causes left ventricular failure, which will result in hypotension and an expansion of the plasma volume due to homeostatic mechanisms.

  9. Reactor power distribution monitor

    International Nuclear Information System (INIS)

    Hoizumi, Atsushi.

    1986-01-01

    Purpose: To grasp the margin for the limit value of the power distribution peaking factor inside the reactor under operation by using the reactor power distribution monitor. Constitution: The monitor is composed of the 'constant' file, (to store in-reactor power distributions obtained from analysis), TIP and thermocouple, lateral output distribution calibrating apparatus, axial output distribution synthesizer and peaking factor synthesizer. The lateral output distribution calibrating apparatus is used to make calibration by comparing the power distribution obtained from the thermocouples to the power distribution obtained from the TIP, and then to provide the power distribution lateral peaking factors. The axial output distribution synthesizer provides the power distribution axial peaking factors in accordance with the signals from the out-pile neutron flux detector. These axial and lateral power peaking factors are synthesized with high precision in the three-dimensional format and can be monitored at any time. (Kamimura, M.)

  10. Assessing quality in cardiac surgery

    Directory of Open Access Journals (Sweden)

    Samer A.M. Nashef

    2005-07-01

    Full Text Available There is a the strong temporal, if not causal, link between the intervention and the outcome in cardiac surgery and therefore a link becomes established between operative mortality and the measurement of surgical performance. In Britain the law stipulates that data collected by any public body or using public funds must be made freely available. Tools and mechanisms we devise and develop are likely to form the models on which the quality of care is assessed in other surgical and perhaps medical specialties. Measuring professional performance should be done by the profession. To measure risk there are a number of scores as crude mortality is not enough. A very important benefit of assessing the risk of death is to use this knowledge in the determination of the indication to operate. The second benefit is in the assessment of the quality of care as risk prediction gives a standard against performance of hospitals and surgeons. Peer review and “naming and shaming” are two mechanisms to monitor quality. There are two potentially damaging outcomes from the publication of results in a league-table form: the first is the damage to the hospital; the second is to refuse to operate on high-risk patients. There is a real need for quality monitoring in medicine in general and in cardiac surgery in particular. Good quality surgical work requires robust knowledge of three crucial variables: activity, risk prediction and performance. In Europe, the three major specialist societies have agreed to establish the European Cardiovascular and Thoracic Surgery Institute of Accreditation (ECTSIA. Performance monitoring is soon to become imperative. If we surgeons are not on board, we shall have no control on its final destination, and the consequences may be equally damaging to us and to our patients.

  11. Role of Nuclear Medicine in the cardiac resinchronization therapy

    Energy Technology Data Exchange (ETDEWEB)

    Brandao, Simone Cristina Soares, E-mail: simonecordis@yahoo.com.br [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil); Giorgi, Maria Clementina Pinto; D' Orio, Silvana Angelina; Meneghetti, Jose Claudio [Instituto do Coracao (InCor/FM/USP), Sao Paulo, SP (Brazil)

    2011-10-15

    Cardiac resynchronization therapy (CRT) emerged as one of the most promising approaches in the treatment of cardiac dyssynchrony in heart failure patients' refractory to medical treatment. However, despite very promising clinical and functional results, individual response analyses show that a significant number of patients do not respond to treatment. The role of nuclear medicine and molecular imaging in the selection of CRT candidates by the assessment of cardiac dyssynchrony, myocardial viability, myocardial perfusion and blood flow and sympathetic cardiac activity has been discussed in this review. The potential utilization of this tool to improve the comprehension of detrimental effects of dyssynchrony on cardiac function and the evaluation and monitoring of the response to CRT were also considered. Other molecular targets that characterize glucose and fatty acid metabolism, apoptosis, angiotensin converting enzyme activity and angiogenesis that can be evaluated with this technique were described. (author)

  12. Role of Nuclear Medicine in the cardiac resinchronization therapy

    Energy Technology Data Exchange (ETDEWEB)

    Brandao, Simone Cristina Soares, E-mail: simonecordis@yahoo.com.br [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil); Giorgi, Maria Clementina Pinto; D' Orio, Silvana Angelina; Meneghetti, Jose Claudio [Instituto do Coracao (InCor/FM/USP), Sao Paulo, SP (Brazil)

    2011-10-15

    Cardiac resynchronization therapy (CRT) emerged as one of the most promising approaches in the treatment of cardiac dyssynchrony in heart failure patients' refractory to medical treatment. However, despite very promising clinical and functional results, individual response analyses show that a significant number of patients do not respond to treatment. The role of nuclear medicine and molecular imaging in the selection of CRT candidates by the assessment of cardiac dyssynchrony, myocardial viability, myocardial perfusion and blood flow and sympathetic cardiac activity has been discussed in this review. The potential utilization of this tool to improve the comprehension of detrimental effects of dyssynchrony on cardiac function and the evaluation and monitoring of the response to CRT were also considered. Other molecular targets that characterize glucose and fatty acid metabolism, apoptosis, angiotensin converting enzyme activity and angiogenesis that can be evaluated with this technique were described. (author)

  13. LOAD THAT MAXIMIZES POWER OUTPUT IN COUNTERMOVEMENT JUMP

    Directory of Open Access Journals (Sweden)

    Pedro Jimenez-Reyes

    2016-02-01

    Full Text Available ABSTRACT Introduction: One of the main problems faced by strength and conditioning coaches is the issue of how to objectively quantify and monitor the actual training load undertaken by athletes in order to maximize performance. It is well known that performance of explosive sports activities is largely determined by mechanical power. Objective: This study analysed the height at which maximal power output is generated and the corresponding load with which is achieved in a group of male-trained track and field athletes in the test of countermovement jump (CMJ with extra loads (CMJEL. Methods: Fifty national level male athletes in sprinting and jumping performed a CMJ test with increasing loads up to a height of 16 cm. The relative load that maximized the mechanical power output (Pmax was determined using a force platform and lineal encoder synchronization and estimating the power by peak power, average power and flight time in CMJ. Results: The load at which the power output no longer existed was at a height of 19.9 ± 2.35, referring to a 99.1 ± 1% of the maximum power output. The load that maximizes power output in all cases has been the load with which an athlete jump a height of approximately 20 cm. Conclusion: These results highlight the importance of considering the height achieved in CMJ with extra load instead of power because maximum power is always attained with the same height. We advise for the preferential use of the height achieved in CMJEL test, since it seems to be a valid indicative of an individual's actual neuromuscular potential providing a valid information for coaches and trainers when assessing the performance status of our athletes and to quantify and monitor training loads, measuring only the height of the jump in the exercise of CMJEL.

  14. Comprehensive cardiac rehabilitation

    DEFF Research Database (Denmark)

    Kruse, Marie; Hochstrasser, Stefan; Zwisler, Ann-Dorthe O

    2006-01-01

    OBJECTIVES: The costs of comprehensive cardiac rehabilitation are established and compared to the corresponding costs of usual care. The effect on health-related quality of life is analyzed. METHODS: An unprecedented and very detailed cost assessment was carried out, as no guidelines existed...... and may be as high as euro 1.877. CONCLUSIONS: Comprehensive cardiac rehabilitation is more costly than usual care, and the higher costs are not outweighed by a quality of life gain. Comprehensive cardiac rehabilitation is, therefore, not cost-effective....

  15. Dual energy cardiac CT.

    Science.gov (United States)

    Carrascosa, Patricia; Deviggiano, Alejandro; Rodriguez-Granillo, Gastón

    2017-06-01

    Conventional single energy CT suffers from technical limitations related to the polychromatic nature of X-rays. Dual energy cardiac CT (DECT) shows promise to attenuate and even overcome some of these limitations, and might broaden the scope of patients eligible for cardiac CT towards the inclusion of higher risk patients. This might be achieved as a result of both safety (contrast reduction) and physiopathological (myocardial perfusion and characterization) issues. In this article, we will review the main clinical cardiac applications of DECT, that can be summarized in two core aspects: coronary artery evaluation, and myocardial evaluation.

  16. Cardiac function of the naked mole-rat: ecophysiological responses to working underground.

    Science.gov (United States)

    Grimes, Kelly M; Voorhees, Andrew; Chiao, Ying Ann; Han, Hai-Chao; Lindsey, Merry L; Buffenstein, Rochelle

    2014-03-01

    The naked mole-rat (NMR) is a strictly subterranean rodent with a low resting metabolic rate. Nevertheless, it can greatly increase its metabolic activity to meet the high energetic demands associated with digging through compacted soils in its xeric natural habitat where food is patchily distributed. We hypothesized that the NMR heart would naturally have low basal function and exhibit a large cardiac reserve, thereby mirroring the species' low basal metabolism and large metabolic scope. Echocardiography showed that young (2-4 yr old) healthy NMRs have low fractional shortening (28 ± 2%), ejection fraction (43 ± 2%), and cardiac output (6.5 ± 0.4 ml/min), indicating low basal cardiac function. Histology revealed large NMR cardiomyocyte cross-sectional area (216 ± 10 μm(2)) and cardiac collagen deposition of 2.2 ± 0.4%. Neither of these histomorphometric traits was considered pathological, since biaxial tensile testing showed no increase in passive ventricular stiffness. NMR cardiomyocyte fibers showed a low degree of rotation, contributing to the observed low NMR cardiac contractility. Interestingly, when the exercise mimetic dobutamine (3 μg/g ip) was administered, NMRs showed pronounced increases in fractional shortening, ejection fraction, cardiac output, and stroke volume, indicating an increased cardiac reserve. The relatively low basal cardiac function and enhanced cardiac reserve of NMRs are likely to be ecophysiological adaptations to life in an energetically taxing environment.

  17. Movement monitoring device

    International Nuclear Information System (INIS)

    Ichikawa, Takashi; Yoneda, Yasuaki; Hanatsumi, Masaharu.

    1997-01-01

    The present invention provides a device suitable to accurate recognition for the moving state of reactor core fuels as an object to be monitored in a nuclear power plant. Namely, the device of the present invention prepares each of scheduled paths for the movement of the object to be monitored and executed moving paths along with the movement based on the information of the movement obtained from scheduled information for the movement of the reactor core fuels as a object to be monitored and the actual movement of the object to be monitored. The results of the preparation are outputted. As an output mode, (1) the results of preparation for each of the paths for movement and the results of the monitoring obtained by monitoring the state of the object to be monitored are jointed and outputted, (2) images showing each of the paths for the movement are formed, and the formed images are displayed on a screen, and (3) each of the moving paths is prepared as an image, and the image is displayed together with the image of the regions before and after the movement of the object to be monitored. In addition, obtained images of each of the paths for the movement and the monitored images obtained by monitoring the state of the object to be monitored are joined and displayed. (I.S.)

  18. Energy and output dynamics in Bangladesh

    International Nuclear Information System (INIS)

    Paul, Biru Paksha; Uddin, Gazi Salah

    2011-01-01

    The relationship between energy consumption and output is still ambiguous in the existing literature. The economy of Bangladesh, having spectacular output growth and rising energy demand as well as energy efficiency in recent decades, can be an ideal case for examining energy-output dynamics. We find that while fluctuations in energy consumption do not affect output fluctuations, movements in output inversely affect movements in energy use. The results of Granger causality tests in this respect are consistent with those of innovative accounting that includes variance decompositions and impulse responses. Autoregressive distributed lag models also suggest a role of output in Bangladesh's energy use. Hence, the findings of this study have policy implications for other developing nations where measures for energy conservation and efficiency can be relevant in policymaking.

  19. Theoretical analysis of magnetic sensor output voltage

    International Nuclear Information System (INIS)

    Liu Haishun; Dun Chaochao; Dou Linming; Yang Weiming

    2011-01-01

    The output voltage is an important parameter to determine the stress state in magnetic stress measurement, the relationship between the output voltage and the difference in the principal stresses was investigated by a comprehensive application of magnetic circuit theory, magnetization theory, stress analysis as well as the law of electromagnetic induction, and a corresponding quantitative equation was derived. It is drawn that the output voltage is proportional to the difference in the principal stresses, and related to the angle between the principal stress and the direction of the sensor. This investigation provides a theoretical basis for the principle stresses measurement by output voltage. - Research highlights: → A comprehensive investigation of magnetic stress signal. → Derived a quantitative equation about output voltage and the principal stresses. → The output voltage is proportional to the difference of the principal stresses. → Provide a theoretical basis for the principle stresses measurement.

  20. Output Control Using Feedforward And Cascade Controllers

    Science.gov (United States)

    Seraji, Homayoun

    1990-01-01

    Report presents theoretical study of open-loop control elements in single-input, single-output linear system. Focus on output-control (servomechanism) problem, in which objective is to find control scheme that causes output to track certain command inputs and to reject certain disturbance inputs in steady state. Report closes with brief discussion of characteristics and relative merits of feedforward, cascade, and feedback controllers and combinations thereof.

  1. Cardiac Catheterization (For Parents)

    Science.gov (United States)

    ... cases, the doctor might call for a cardiac magnetic resonance imaging (MRI) scan or a CAT scan . ... first couple of days. This means no heavy lifting (more than 10 pounds) and no sports. After ...

  2. Cardiac Catheterization (For Teens)

    Science.gov (United States)

    ... doctor may also call for a cardiac MRI (magnetic resonance imaging) scan or a CT (computerized tomography) ... first couple of days. This means no heavy lifting (nothing over 10 pounds) and no sports. After ...

  3. Buerger's Disease and Anaesthesia: The Neglected Cardiac Angle

    Directory of Open Access Journals (Sweden)

    Shagun Bhatia Shah

    2015-08-01

    Full Text Available Distal limb amputations and respiratory complications are common in patients with Buerger’s disease. Nicotine in cigarette is arrhythmogenic as it blocks cardiac potassium channels. Preoperative Holter ECG monitoring may be useful if preoperative electrocardiogram is normal. If the patient is undergoing major surgery, preservative free lignocaine & amiodarone infusions and a cardioverter defibrillator should be available for the intraoperative cardiac rhythm disturbances.

  4. Autonomic cardiac innervation

    Science.gov (United States)

    Hasan, Wohaib

    2013-01-01

    Autonomic cardiac neurons have a common origin in the neural crest but undergo distinct developmental differentiation as they mature toward their adult phenotype. Progenitor cells respond to repulsive cues during migration, followed by differentiation cues from paracrine sources that promote neurochemistry and differentiation. When autonomic axons start to innervate cardiac tissue, neurotrophic factors from vascular tissue are essential for maintenance of neurons before they reach their targets, upon which target-derived trophic factors take over final maturation, synaptic strength and postnatal survival. Although target-derived neurotrophins have a central role to play in development, alternative sources of neurotrophins may also modulate innervation. Both developing and adult sympathetic neurons express proNGF, and adult parasympathetic cardiac ganglion neurons also synthesize and release NGF. The physiological function of these “non-classical” cardiac sources of neurotrophins remains to be determined, especially in relation to autocrine/paracrine sustenance during development.   Cardiac autonomic nerves are closely spatially associated in cardiac plexuses, ganglia and pacemaker regions and so are sensitive to release of neurotransmitter, neuropeptides and trophic factors from adjacent nerves. As such, in many cardiac pathologies, it is an imbalance within the two arms of the autonomic system that is critical for disease progression. Although this crosstalk between sympathetic and parasympathetic nerves has been well established for adult nerves, it is unclear whether a degree of paracrine regulation occurs across the autonomic limbs during development. Aberrant nerve remodeling is a common occurrence in many adult cardiovascular pathologies, and the mechanisms regulating outgrowth or denervation are disparate. However, autonomic neurons display considerable plasticity in this regard with neurotrophins and inflammatory cytokines having a central regulatory

  5. Cardiac imaging in adults

    International Nuclear Information System (INIS)

    Jaffe, C.C.

    1987-01-01

    This book approaches adult cardiac disease from the correlative imaging perspective. It includes chest X-rays and angiographs, 2-dimensional echocardiograms with explanatory diagrams for clarity, plus details on digital radiology, nuclear medicine techniques, CT and MRI. It also covers the normal heart, valvular heart disease, myocardial disease, pericardial disease, bacterial endocarditis, aortic aneurysm, cardiac tumors, and congenital heart disease of the adult. It points out those aspects where one imaging technique has significant superiority

  6. Cardiac imaging in adults

    Energy Technology Data Exchange (ETDEWEB)

    Jaffe, C.C.

    1987-01-01

    This book approaches adult cardiac disease from the correlative imaging perspective. It includes chest X-rays and angiographs, 2-dimensional echocardiograms with explanatory diagrams for clarity, plus details on digital radiology, nuclear medicine techniques, CT and MRI. It also covers the normal heart, valvular heart disease, myocardial disease, pericardial disease, bacterial endocarditis, aortic aneurysm, cardiac tumors, and congenital heart disease of the adult. It points out those aspects where one imaging technique has significant superiority.

  7. Cardiac biomarkers in Neonatology

    OpenAIRE

    Vijlbrief, D.C.

    2015-01-01

    In this thesis, the role for cardiac biomarkers in neonatology was investigated. Several clinically relevant results were reported. In term and preterm infants, hypoxia and subsequent adaptation play an important role in cardiac biomarker elevation. The elevated natriuretic peptides are indicative of abnormal function; elevated troponins are suggestive for cardiomyocyte damage. This methodology makes these biomarkers of additional value in the treatment of newborn infants, separate or as a co...

  8. Post cardiac injury syndrome

    DEFF Research Database (Denmark)

    Nielsen, S L; Nielsen, F E

    1991-01-01

    The post-pericardiotomy syndrome is a symptom complex which is similar in many respects to the post-myocardial infarction syndrome and these are summarized under the diagnosis of the Post Cardiac Injury Syndrome (PCIS). This condition, which is observed most frequently after open heart surgery, i...... on the coronary vessels, with cardiac tamponade and chronic pericardial exudate. In the lighter cases, PCIS may be treated with NSAID and, in the more severe cases, with systemic glucocorticoid which has a prompt effect....

  9. Awareness in cardiac anesthesia.

    LENUS (Irish Health Repository)

    Serfontein, Leon

    2010-02-01

    Cardiac surgery represents a sub-group of patients at significantly increased risk of intraoperative awareness. Relatively few recent publications have targeted the topic of awareness in this group. The aim of this review is to identify areas of awareness research that may equally be extrapolated to cardiac anesthesia in the attempt to increase understanding of the nature and significance of this scenario and how to reduce it.

  10. Acute cardiac support with intravenous milrinone promotes recovery from early brain injury in a murine model of severe subarachnoid haemorrhage.

    Science.gov (United States)

    Mutoh, Tomoko; Mutoh, Tatsushi; Nakamura, Kazuhiro; Yamamoto, Yukiko; Tsuru, Yoshiharu; Tsubone, Hirokazu; Ishikawa, Tatsuya; Taki, Yasuyuki

    2017-04-01

    Early brain injury/ischaemia (EBI) is a serious complication early after subarachnoid haemorrhage (SAH) that contributes to development of delayed cerebral ischaemia (DCI). This study aimed to determine the role of inotropic cardiac support using milrinone (MIL) on restoring acute cerebral hypoperfusion attributable to EBI and improving outcomes after experimental SAH. Forty-three male C57BL/6 mice were assigned to either sham surgery (SAH-sham), SAH induced by endovascular perforation plus postconditioning with 2% isoflurane (Control), or SAH plus isoflurane combined with MIL with and without hypoxia-inducible factor inhibitor (HIF-I) pretreatment. Cardiac output (CO) during intravenous MIL infusion (0.25-0.75 μg/kg/min) between 1.5 and 2.5 hours after SAH induction was monitored with Doppler echocardiography. Magnetic resonance imaging (MRI)-continuous arterial spin labelling was used for quantitative cerebral blood flow (CBF) measurements. Neurobehavioral function was assessed daily by neurological score and open field test. DCI was analyzed 3 days later by determining infarction on MRI. Mild reduction of cardiac output (CO) and global cerebral blood flow (CBF) depression were notable early after SAH. MIL increased CO in a dose-dependent manner (P<.001), which was accompanied by improved hypoperfusion, incidence of DCI and functional recovery than Control (P<.05). The neuroprotective effects afforded by MIL or Control were attenuated by hypoxia-inducible factor (HIF) inhibition (P<.05). These results suggest that MIL improves acute hypoperfusion by its inotropic effect, leading to neurobehavioral improvement in mice after severe SAH, in which HIF may be acting as a critical mediator. © 2017 John Wiley & Sons Australia, Ltd.

  11. Analysis of output trends from Varian 2100C/D and 600C/D accelerators

    International Nuclear Information System (INIS)

    Grattan, M W D; Hounsell, A R

    2011-01-01

    Analysis of Varian linear accelerator output trends is reported. Two groups, consisting of four matched Varian 2100C/D and four matched Varian 600C/D accelerators, with different designs of monitor chamber, have been investigated and the data acquired from regular calibrated ion chamber/electrometer measurements of the output performance of the eight accelerators analysed. The trend of machine output with time, having removed the effect of adjusting the monitor chamber response, was compared on a monthly and annual basis for monitor chambers with ages ranging between 1 year and 7 years. The results indicate that the response is generally consistent within each set of accelerators with different monitor chamber designs. Those used in a Varian 600C/D machine result in a reduction in measured output over time, with an average monthly reduction of 0.35 ± 0.09% over the course of the first 4 years of use. The chambers used in a 2100C/D accelerator result in an increase in measured output over time, with an average monthly increase of 0.26 ± 0.09% over the course of the first 4 years of use. The output increase then reduces towards the end of this period of time, with the average monthly change falling to -0.03 ± 0.02% for the following 3 years. The output response trend was similar for all clinical energies used on the 2100C/D accelerators--6, 15 MV x-ray beams, and 4, 6, 9, 12, 16 and 20 MeV electron beams. By tracking these changes it has been possible to predict the response over time to allow appropriate adjustments in monitor chamber response to maintain a measured accelerator output within tolerance and give confidence in performance. It has also provided data to indicate the need for planned preventative intervention and indicate if the monitor chamber response is behaving as expected. (note)

  12. Donor age is a predictor of early low output after heart transplantation.

    Science.gov (United States)

    Fujino, Takeo; Kinugawa, Koichiro; Nitta, Daisuke; Imamura, Teruhiko; Maki, Hisataka; Amiya, Eisuke; Hatano, Masaru; Kimura, Mitsutoshi; Kinoshita, Osamu; Nawata, Kan; Komuro, Issei; Ono, Minoru

    2016-05-01

    Using hearts from marginal donors could be related to increased risk of primary graft dysfunction and poor long-term survival. However, factors associated with delayed myocardial recovery after heart transplantation (HTx) remain unknown. We sought to clarify risk factors that predict early low output after HTx, and investigated whether early low output affects mid-term graft dysfunction. We retrospectively analyzed patients who had undergone HTx at The University of Tokyo Hospital. We defined early low output patients as those whose cardiac index (CI) was early low output group, and the others into early preserved output group. We performed univariable logistic analysis and found that donor age was the only significant factor that predicted early low output (odds ratio 1.107, 95% confidence interval 1.034-1.210, p=0.002). CI of early low output patients gradually increased and it caught up with that of early preserved output patients at 2 weeks after HTx (2.4±0.6 L/min/m(2) in early low output group vs 2.5±0.5 L/min/m(2) in early preserved output group, p=0.684). Plasma B-type natriuretic peptide concentration of early low output patients was higher (1118.5±1250.2 pg/ml vs 526.4±399.5 pg/ml; p=0.033) at 1 week, 703.6±518.4 pg/ml vs 464.6±509.0 pg/ml (p=0.033) at 2 weeks, and 387.7±231.9 pg/ml vs 249.4±209.5 pg/ml (p=0.010) at 4 weeks after HTx, and it came down to that of early preserved output patients at 12 weeks after HTx. Donor age was a predictor of early low output after HTx. We should be careful after HTx from old donors. However, hemodynamic parameters of early low output patients gradually caught up with those of early preserved output patients. Copyright © 2015 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  13. Basal Ganglia Outputs Map Instantaneous Position Coordinates during Behavior

    Science.gov (United States)

    Barter, Joseph W.; Li, Suellen; Sukharnikova, Tatyana; Rossi, Mark A.; Bartholomew, Ryan A.

    2015-01-01

    The basal ganglia (BG) are implicated in many movement disorders, yet how they contribute to movement remains unclear. Using wireless in vivo recording, we measured BG output from the substantia nigra pars reticulata (SNr) in mice while monitoring their movements with video tracking. The firing rate of most nigral neurons reflected Cartesian coordinates (either x- or y-coordinates) of the animal's head position during movement. The firing rates of SNr neurons are either positively or negatively correlated with the coordinates. Using an egocentric reference frame, four types of neurons can be classified: each type increases firing during movement in a particular direction (left, right, up, down), and decreases firing during movement in the opposite direction. Given the high correlation between the firing rate and the x and y components of the position vector, the movement trajectory can be reconstructed from neural activity. Our results therefore demonstrate a quantitative and continuous relationship between BG output and behavior. Thus, a steady BG output signal from the SNr (i.e., constant firing rate) is associated with the lack of overt movement, when a stable posture is maintained by structures downstream of the BG. Any change in SNr firing rate is associated with a change in position (i.e., movement). We hypothesize that the SNr output quantitatively determines the direction, velocity, and amplitude of voluntary movements. By changing the reference signals to downstream position control systems, the BG can produce transitions in body configurations and initiate actions. PMID:25673860

  14. [Cardiac involvement in Churg-Strauss syndrome].

    Science.gov (United States)

    Brucato, Antonio; Maestroni, Silvia; Masciocco, Gabriella; Ammirati, Enrico; Bonacina, Edgardo; Pedrotti, Patrizia

    2015-09-01

    agents, particularly cyclophosphamide in case of myocardial inflammation. Thus, early diagnosis of cardiac involvement and subsequent therapy may prevent progression of cardiac disease. At present, the role of troponin and brain natriuretic peptide in monitoring and therapy remains unclear. Orthotopic heart transplantation is feasible in case of severe disease, even if the experience is limited in -EGPA, and optimal post-transplantation immunosuppressive strategy has yet to be defined.

  15. Direct Cardiac Reprogramming: Advances in Cardiac Regeneration

    Directory of Open Access Journals (Sweden)

    Olivia Chen

    2015-01-01

    Full Text Available Heart disease is one of the lead causes of death worldwide. Many forms of heart disease, including myocardial infarction and pressure-loading cardiomyopathies, result in irreversible cardiomyocyte death. Activated fibroblasts respond to cardiac injury by forming scar tissue, but ultimately this response fails to restore cardiac function. Unfortunately, the human heart has little regenerative ability and long-term outcomes following acute coronary events often include chronic and end-stage heart failure. Building upon years of research aimed at restoring functional cardiomyocytes, recent advances have been made in the direct reprogramming of fibroblasts toward a cardiomyocyte cell fate both in vitro and in vivo. Several experiments show functional improvements in mouse models of myocardial infarction following in situ generation of cardiomyocyte-like cells from endogenous fibroblasts. Though many of these studies are in an early stage, this nascent technology holds promise for future applications in regenerative medicine. In this review, we discuss the history, progress, methods, challenges, and future directions of direct cardiac reprogramming.

  16. Neuromuscular blockade in cardiac surgery: An update for clinicians

    Directory of Open Access Journals (Sweden)

    Hemmerling Thomas

    2008-01-01

    Full Text Available There have been great advancements in cardiac surgery over the last two decades; the widespread use of off-pump aortocoronary bypass surgery, minimally invasive cardiac surgery, and robotic surgery have also changed the face of cardiac anaesthesia. The concept of "Fast-track anaesthesia" demands the use of nondepolarising neuromuscular blocking drugs with short duration of action, combining the ability to provide (if necessary sufficiently profound neuromuscular blockade during surgery and immediate re-establishment of normal neuromuscular transmission at the end of surgery. Postoperative residual muscle paralysis is one of the major hurdles for immediate or early extubation after cardiac surgery. Nondepolarising neuromuscular blocking drugs for cardiac surgery should therefore be easy to titrate, of rapid onset and short duration of action with a pathway of elimination independent from hepatic or renal dysfunction, and should equally not affect haemodynamic stability. The difference between repetitive bolus application and continuous infusion is outlined in this review, with the pharmacodynamic and pharmacokinetic characteristics of vecuronium, pancuronium, rocuronium, and cisatracurium. Kinemyography and acceleromyography are the most important currently used neuromuscular monitoring methods. Whereas monitoring at the adductor pollicis muscle is appropriate at the end of surgery, monitoring of the corrugator supercilii muscle better reflects neuromuscular blockade at more central, profound muscles, such as the diaphragm, larynx, or thoraco-abdominal muscles. In conclusion, cisatracurium or rocuronium is recommended for neuromuscular blockade in modern cardiac surgery.

  17. Pattern of perioperative cardiac arrests at University of Maiduguri Teaching Hospital.

    Science.gov (United States)

    Kwari, Y D; Bello, M R; Eni, U E

    2010-01-01

    Perioperative cardiac arrests and death on the table represent the most serious complications of surgery and anaesthesia. This paper was designed to study their pattern, causes and outcomes following cardiopulmonary resuscitation (CPR) and intensive care unit (ICU) management in our institution. Three year retrospective review of perioperative cardiac arrests and death on operating table following surgical procedure under anaesthesia. For each cardiac arrest or death on the table the sequence of events leading to the arrest was evaluated using case notes, anaesthetic chart and ICU records. Study variables which include demographic data, ASA score, anaesthetic technique, causes and outcome were analysed and discussed. Fourteen perioperative cardiac arrests were encountered following 4051 anaesthetics administered over the three year study period. Twelve out of the fourteen cardiac arrests occurred following general anaesthesia, while the remaining two occurred following spinal anaesthesia. There was no cardiac arrest following local anaesthesia. Children suffered more cardiac arrest than adults. ASA class III and IV risk status suffered more arrests than ASA I and II. Hypoxia from airway problems was the commonest cause of cardiac arrest followed by septic shock. Monitoring with pulse oximeter was done in only 4 out of the 14 cardiac arrests. Only 2 (14%) out of 14 cardiac arrests recovered to home discharge, one of them with significant neurological deficit. Majority of arrests were due to hypoxia from airway problems that were not detected early There is need to improve on patient monitoring, knowledge of CPR and intensive care so as to improve the outcome of perioperative cardiac arrest.

  18. DIST/AVC Out-Put Definition.

    Science.gov (United States)

    Wilkinson, Gene L.

    The first stage of development of a management information system for DIST/AVC (Division of Instructional Technology/Audio-Visual Center) is the definition of out-put units. Some constraints on the definition of output units are: 1) they should reflect goals of the organization, 2) they should reflect organizational structure and procedures, and…

  19. Fast multi-output relevance vector regression

    OpenAIRE

    Ha, Youngmin

    2017-01-01

    This paper aims to decrease the time complexity of multi-output relevance vector regression from O(VM^3) to O(V^3+M^3), where V is the number of output dimensions, M is the number of basis functions, and V

  20. Early-Transition Output Decline Revisited

    Directory of Open Access Journals (Sweden)

    Crt Kostevc

    2016-05-01

    Full Text Available In this paper we revisit the issue of aggregate output decline that took place in the early transition period. We propose an alternative explanation of output decline that is applicable to Central- and Eastern-European countries. In the first part of the paper we develop a simple dynamic general equilibrium model that builds on work by Gomulka and Lane (2001. In particular, we consider price liberalization, interpreted as elimination of distortionary taxation, as a trigger of the output decline. We show that price liberalization in interaction with heterogeneous adjustment costs and non-employment benefits lead to aggregate output decline and surge in wage inequality. While these patterns are consistent with actual dynamics in CEE countries, this model cannot generate output decline in all sectors. Instead sectors that were initially taxed even exhibit output growth. Thus, in the second part we consider an alternative general equilibrium model with only one production sector and two types of labor and distortion in a form of wage compression during the socialist era. The trigger for labor mobility and consequently output decline is wage liberalization. Assuming heterogeneity of workers in terms of adjustment costs and non-employment benefits can explain output decline in all industries.

  1. Assessing the psychological factors predicting workers' output ...

    African Journals Online (AJOL)

    The study investigated job security, communication skills, interpersonal relationship and emotional intelligence as correlates of workers' output among local government employees in Oyo State. The research adopted descriptive design of an expose facto type. The research instruments used includes Workers' output scale, ...

  2. The left ventricle as a mechanical engine: from Leonardo da Vinci to the echocardiographic assessment of peak power output-to-left ventricular mass.

    Science.gov (United States)

    Dini, Frank L; Guarini, Giacinta; Ballo, Piercarlo; Carluccio, Erberto; Maiello, Maria; Capozza, Paola; Innelli, Pasquale; Rosa, Gian M; Palmiero, Pasquale; Galderisi, Maurizio; Razzolini, Renato; Nodari, Savina

    2013-03-01

    The interpretation of the heart as a mechanical engine dates back to the teachings of Leonardo da Vinci, who was the first to apply the laws of mechanics to the function of the heart. Similar to any mechanical engine, whose performance is proportional to the power generated with respect to weight, the left ventricle can be viewed as a power generator whose performance can be related to left ventricular mass. Stress echocardiography may provide valuable information on the relationship between cardiac performance and recruited left ventricular mass that may be used in distinguishing between adaptive and maladaptive left ventricular remodeling. Peak power output-to-mass, obtained during exercise or pharmacological stress echocardiography, is a measure that reflects the number of watts that are developed by 100 g of left ventricular mass under maximal stimulation. Power output-to-mass may be calculated as left ventricular power output per 100 g of left ventricular mass: 100× left ventricular power output divided by left ventricular mass (W/100 g). A simplified formula to calculate power output-to-mass is as follows: 0.222 × cardiac output (l/min) × mean blood pressure (mmHg)/left ventricular mass (g). When the integrity of myocardial structure is compromised, a mismatch becomes apparent between maximal cardiac power output and left ventricular mass; when this occurs, a reduction of the peak power output-to-mass index is observed.

  3. Transesophageal Doppler reliably tracks changes in cardiac output in comparison with intermittent pulmonary artery thermodilution in cardiac surgery patients

    DEFF Research Database (Denmark)

    Møller-Sørensen, Hasse; Cordtz, Joakim; Østergaard, Morten

    2017-01-01

    completed the study. Each patient were placed in the following successive positions: (1) supine, (2) head-down tilt, (3) head-up tilt, (4) supine, (5) supine with phenylephrine administration, (6) pace heart rate 80 beats per minute (bpm), (7) pace heart rate 110 bpm. The agreement of compared data...

  4. Peri-operative troponin monitoring using a prototype high-sensitivity cardiac troponin I (hs-cTnI) assay: comparisons with hs-cTnT and contemporary cTnI assays.

    LENUS (Irish Health Repository)

    Lee, Graham R

    2013-09-18

    Non-cardiac surgery is associated with major vascular complications and higher incidences of elevated plasma troponin (cTn) concentration. Goal-directed therapy (GDT) is a stroke volume (SV)-guided approach to intravenous (IV) fluid therapy that improves tissue perfusion, oxygenation and reduces post-operative complications. In patients undergoing major gastro-intestinal surgery, we compared high sensitive and contemporary troponin assays and correlated results with patient outcome.

  5. Electrical velocimetry for non-invasive monitoring of the closure of the ductus arteriosus in preterm infants.

    Science.gov (United States)

    Rodríguez Sánchez de la Blanca, Ana; Sánchez Luna, M; González Pacheco, N; Arriaga Redondo, M; Navarro Patiño, N

    2018-02-01

    Closure of a patent ductus arteriosus (PDA) in preterm infants modifies cardiac output and induces adaptive changes in the hemodynamic situation. The present study aims to analyze those changes, through a non-invasive cardiac output monitor based on blood electrical velocimetry, in preterm babies. A prospective observational study of preterm infants with a gestational age of less than 28 weeks, and a hemodynamic significant PDA, requires intravenous ibuprofen or surgical closure. All patients were monitored with electrical velocimetry before treatment and through the following 72 h. Two groups were defined, ibuprofen and surgical closure. Variations of cardiac output were analyzed from the basal situation and at 1, 8, 24, 48, and 72 h on each group. During a 12-month period, 18 patients were studied. The median gestational age in the ibuprofen group (12/18) was 26 +5  weeks (25 +5 -27 +3 ) with a median birth weight of 875 (670-1010) g. The cardiac output index (CI) value was 0.29 l/kg/min (0.24-0.34). Among the patients with confirmed ductus closure (50%), a significant CI decrease was shown (0.24 vs 0.29 l/kg/min; P 0.03) after 72 h (three ibuprofen doses). A statistically significant decrease in systolic volume (SVI) was found: 1.62 vs 1.88 ml/kg, P 0.03 with a decrease in contractility (ICON), 85 vs 140, P 0.02. The gestational age in the surgical group (6/18) was 25 +2  weeks (24-26 +3 ) with a median weight of 745 (660-820) g. All patients in this group showed a decrease in the immediate postoperative CI (1 h after surgery) 0.24 vs 0.30 l/kg/min, P 0.05, and a significant decrease in contractility (ICON 77 vs 147, P 0.03). In addition, a no statistically significant decrease in SVI (1.54 vs 1.83 ml/kg, P 0.06), as well as an increase in systemic vascular resistance (10,615 vs 8797 dyn/cm 2 , P 0.08), were detected. This deterioration was transient without significant differences in the remaining periods of time evaluated. The surgical closure

  6. Perceiving imitatible stimuli: consequences of isomorphism between input and output.

    Science.gov (United States)

    Wilson, M

    2001-07-01

    For more than a century, psychologists have been intrigued by the idea that mental representations of perceived human actions are closely connected with mental representations of performing those same actions. In this article, connections between input and output representations are considered in terms of the potential for imitation. A broad range of evidence suggests that, for imitatible stimuli, input and output representations are isomorphic to one another, allowing mutual influence between perception and motoric planning that is rapid, effortless, and possibly obligatory. Thus, the cognitive consequences of imitatibility may underlie such diverse phenomena as phoneme perception; imitation in neonates; echoic memory; stimulus-response compatibility; conduction aphasia; maintenance rehearsal; and a variety of developmental and social activities such as language acquisition, social learning, empathy, and monitoring one's own behavior.

  7. [Factors involved in the development of vasoplegia after cardiac surgery with extracorporeal circulation. A prospective observational study].

    Science.gov (United States)

    Durán Bruce, M; Gomar Sancho, C; Holguera, J C; Muliterno Español, E

    2014-05-01

    The incidence and risk factors for vasoplegia in the early postoperative period and at 24h are investigated in patients subjected to cardiopulmonary bypass surgery. Vasoplegia following cardiac surgery with cardiopulmonary bypass is associated with a high morbimortality. The risk factors described emerged from retrospective, non-controlled studies. Observational prospective study of 188 consecutive patients subjected to cardiac surgery with cardiopulmonary bypass in a single hospital between November 2011 and May 2012. Emergency surgery or complex procedures were excluded. Vasoplegia was assessed during the immediate postoperative period, and at 24h after surgery, and was defined as a mean arterial pressure below 50mmHg, and the need for a noradrenaline perfusion of more than 0.08μg/kg/min, monitored by cardiac output and systemic vascular resistances. The anaesthetic and cardiopulmonary bypass protocols, as well as haemodynamic management, were the same in all patients. Almost half (48%) of patients had vasoplegia in the immediate postoperative period, and 34% at 24h. Risk factors for immediate vasoplegia development were preoperative use of angiotensin converting enzyme inhibitor drugs, a mean arterial pressure<50mmHg immediately after beginning cardiopulmonary bypass, duration of aortic clamping as well as the cardiopulmonary bypass, and minimum temperature in cardiopulmonary bypass. Vasoplegia at 24h after surgery was correlated to preoperative angiotensin converting enzyme inhibitor drug treatment and cardiopulmonary bypass duration. The incidence of vasoplegia after cardiac surgery with cardiopulmonary bypass is high during the first 24 postoperative hours. Preoperative treatment with angiotensin converting enzyme inhibitor and the mean arterial pressure at the beginning of cardiopulmonary bypass are the more easily controllable risk factors. In patients arriving to surgery with those drugs, treatment or prevention of vasoplejia should be planned. Copyright

  8. Cardiac radiology: centenary review.

    Science.gov (United States)

    de Roos, Albert; Higgins, Charles B

    2014-11-01

    During the past century, cardiac imaging technologies have revolutionized the diagnosis and treatment of acquired and congenital heart disease. Many important contributions to the field of cardiac imaging were initially reported in Radiology. The field developed from the early stages of cardiac imaging, including the use of coronary x-ray angiography and roentgen kymography, to nowadays the widely used echocardiographic, nuclear medicine, cardiac computed tomographic (CT), and magnetic resonance (MR) applications. It is surprising how many of these techniques were not recognized for their potential during their early inception. Some techniques were described in the literature but required many years to enter the clinical arena and presently continue to expand in terms of clinical application. The application of various CT and MR contrast agents for the diagnosis of myocardial ischemia is a case in point, as the utility of contrast agents continues to expand the noninvasive characterization of myocardium. The history of cardiac imaging has included a continuous process of advances in our understanding of the anatomy and physiology of the cardiovascular system, along with advances in imaging technology that continue to the present day.

  9. High Output Piezo/Triboelectric Hybrid Generator

    Science.gov (United States)

    Jung, Woo-Suk; Kang, Min-Gyu; Moon, Hi Gyu; Baek, Seung-Hyub; Yoon, Seok-Jin; Wang, Zhong-Lin; Kim, Sang-Woo; Kang, Chong-Yun

    2015-03-01

    Recently, piezoelectric and triboelectric energy harvesting devices have been developed to convert mechanical energy into electrical energy. Especially, it is well known that triboelectric nanogenerators have a simple structure and a high output voltage. However, whereas nanostructures improve the output of triboelectric generators, its fabrication process is still complicated and unfavorable in term of the large scale and long-time durability of the device. Here, we demonstrate a hybrid generator which does not use nanostructure but generates much higher output power by a small mechanical force and integrates piezoelectric generator into triboelectric generator, derived from the simultaneous use of piezoelectric and triboelectric mechanisms in one press-and-release cycle. This hybrid generator combines high piezoelectric output current and triboelectric output voltage, which produces peak output voltage of ~370 V, current density of ~12 μA.cm-2, and average power density of ~4.44 mW.cm-2. The output power successfully lit up 600 LED bulbs by the application of a 0.2 N mechanical force and it charged a 10 μF capacitor to 10 V in 25 s. Beyond energy harvesting, this work will provide new opportunities for developing a small, built-in power source in self-powered electronics such as mobile electronics.

  10. High Output Piezo/Triboelectric Hybrid Generator

    Science.gov (United States)

    Jung, Woo-Suk; Kang, Min-Gyu; Moon, Hi Gyu; Baek, Seung-Hyub; Yoon, Seok-Jin; Wang, Zhong-Lin; Kim, Sang-Woo; Kang, Chong-Yun

    2015-01-01

    Recently, piezoelectric and triboelectric energy harvesting devices have been developed to convert mechanical energy into electrical energy. Especially, it is well known that triboelectric nanogenerators have a simple structure and a high output voltage. However, whereas nanostructures improve the output of triboelectric generators, its fabrication process is still complicated and unfavorable in term of the large scale and long-time durability of the device. Here, we demonstrate a hybrid generator which does not use nanostructure but generates much higher output power by a small mechanical force and integrates piezoelectric generator into triboelectric generator, derived from the simultaneous use of piezoelectric and triboelectric mechanisms in one press-and-release cycle. This hybrid generator combines high piezoelectric output current and triboelectric output voltage, which produces peak output voltage of ~370 V, current density of ~12 μA·cm−2, and average power density of ~4.44 mW·cm−2. The output power successfully lit up 600 LED bulbs by the application of a 0.2 N mechanical force and it charged a 10 μF capacitor to 10 V in 25 s. Beyond energy harvesting, this work will provide new opportunities for developing a small, built-in power source in self-powered electronics such as mobile electronics. PMID:25791299

  11. Factors influencing the development of low output state in patients with right ventricular infarction

    Energy Technology Data Exchange (ETDEWEB)

    Goto, Yoichi; Kanno, Kazuji; Saito, Muneyasu; Haze, Kazuo; Sumiyoshi, Tetsuya; Fukami, Kenichi; Fujiwara, Yasushi; Hiramori, Katsuhiko; Ikeda, Masao [National Cardiovascular Center, Suita, Osaka (Japan)

    1984-06-01

    Right ventricular infarction is frequently accompanied by a low output state, but the factors influencing the development of this state remain unknown. To elucidate these factors, clinical findings, hemodynamic findings and left ventricular infarct size (Tl-score) calculated from thallium-201 myocardial scintigrams by a circumferential profile method were evaluated in 147 consecutive patients with acute transmural inferior myocardial infarction. They were divided into two groups: 44 patients with right ventricular involvement (RVI group) and 103 patients without right ventricular involvement (IMI group). A low cardiac output state was defined when the cardiac index was less than 2.2 L/min/M/sup 2/. There was a good correlation between Tl-score and any of peak value of serum creatine phosphokinase (CPKmax), total released CPK (CPKr) and left ventricular ejection fraction (LVEF) (r=o.66, 0.74 and -0.54, respectively), indicating the usefulness of Tl-score as an index of left ventricular damage. Compared to the IMI group, the RVI group showed a higher average of age (p < 0.01), lower systemic blood pressure (p < 0.01), higher right atrial pressure (p < 0.001) and lower cardiac index (p < 0.01). Furthermore, the incidence of a low output state (RVI group:47.7% vs IMI group:14.6%, p < 0.001) and mortality (25.0% vs 7.8%, p < 0.01) were higher in the RVI group. However, CPKmax, CPKr, LVEF and Tl-score, which were considered to reflect the severity of left ventricular damage, were not different between the two groups. Tl-score was inversely correlated with cardiac index in the RVI group (r=-0.49, p < 0.05), and with left ventricular stroke work index in the both groups (RVI group; r=-0.46, p < 0.01, IMI group; r=-0.64, p < 0.01).

  12. Primary haemochromatosis. Early detection of commitment myocardium through cardiac magnetic resonance

    International Nuclear Information System (INIS)

    Corbella, F.; Rivas, Carlos; Dragonetti, Laura; Eyheremendy, Eduardo; Calo, Claudia

    2009-01-01

    Primary haemochromatosis is the most common genetic disease of the West (1 in 300 to 400 people). Cardiac involvement during its early stages is not detected by imaging techniques.During this period potentially lethal arrhythmias can occur. Using cardiac magnetic resonance (CMR) with T2 star sequence it is possible an early detection of cardiac involvement as well as a risk stratification and a monitoring the progress of the therapy. [es

  13. Isolated Cardiac Hydatid Cyst

    International Nuclear Information System (INIS)

    Shakil, U.; Rehman, A. U.; Shahid, R.

    2015-01-01

    Hydatid cyst disease is common in our part of the world. Cardiac hydatid cyst is its rare manifestation. We report this case of 48-year male having isolated cardiac hydatid cyst, incidentally found on computed tomography. This patient presented in medical OPD of Combined Military Hospital, Lahore with one month history of mild retrosternal discomfort. His general physical and systemic examinations as well as ECG were unremarkable. Chest X-ray showed an enlarged cardiac shadow with mildly irregular left heart border. Contrast enhanced CT scan of the chest showed a large well defined multiloculated non-enhancing cystic lesion with multiple daughter cysts involving wall of left ventricle and overlying pericardium. Serology for echinococcus confirmed the diagnosis of hydatid cyst. Patient was offered the surgical treatment but he opted for medical treatment only. Albendezol was prescribed. His follow-up echocardiography after one month showed no significant decrease in size of the cyst. (author)

  14. Dependency of blood pressure upon cardiac filling in patients with severe postural hypotension

    DEFF Research Database (Denmark)

    Mehlsen, J; Haedersdal, C; Stokholm, K H

    1994-01-01

    by vasoconstriction. The reduction in cardiac output resulted from reductions in left ventricular end-diastolic volumes with unchanged left ventricular ejection fractions and only moderate increments in heart rate. The study was demonstrated that blood pressure is strongly dependent upon cardiac filling in severe......Autonomic denervation of the vascular bed results theoretically in a stronger dependency of blood pressure upon intravascular volume, and the study described aimed at an investigation of the relation between cardiac filling and arterial blood pressure in patients with severe postural hypotension....... Seven patients were studied during head-up tilt at three different tilt angles using intra-arterial blood pressure recordings and estimates of left ventricular volumes by radioisotope ventriculography. Blood pressure fell dramatically during head-up tilt due to reductions in cardiac output unopposed...

  15. Dependency of blood pressure upon cardiac filling in patients with severe postural hypotension

    DEFF Research Database (Denmark)

    Mehlsen, J; Haedersdal, C; Stokholm, K H

    1994-01-01

    Autonomic denervation of the vascular bed results theoretically in a stronger dependency of blood pressure upon intravascular volume, and the study described aimed at an investigation of the relation between cardiac filling and arterial blood pressure in patients with severe postural hypotension....... Seven patients were studied during head-up tilt at three different tilt angles using intra-arterial blood pressure recordings and estimates of left ventricular volumes by radioisotope ventriculography. Blood pressure fell dramatically during head-up tilt due to reductions in cardiac output unopposed...... by vasoconstriction. The reduction in cardiac output resulted from reductions in left ventricular end-diastolic volumes with unchanged left ventricular ejection fractions and only moderate increments in heart rate. The study was demonstrated that blood pressure is strongly dependent upon cardiac filling in severe...

  16. Quantitative cardiac computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Thelen, M.; Dueber, C.; Wolff, P.; Erbel, R.; Hoffmann, T.

    1985-06-01

    The scope and limitations of quantitative cardiac CT have been evaluated in a series of experimental and clinical studies. The left ventricular muscle mass was estimated by computed tomography in 19 dogs (using volumetric methods, measurements in two axes and planes and reference volume). There was good correlation with anatomical findings. The enddiastolic volume of the left ventricle was estimated in 22 patients with cardiomyopathies; using angiography as a reference, CT led to systematic under-estimation. It is also shown that ECG-triggered magnetic resonance tomography results in improved visualisation and may be expected to improve measurements of cardiac morphology.

  17. Systemic arteriovenous malformations as a cause of cardiac failure: Treatment with embolization

    International Nuclear Information System (INIS)

    Smith, E.J.; Hemingway, A.P.; Allison, D.J.

    1987-01-01

    Massive cogenital systemic arteriovenous malformations (AVMs) present considerable management problems for clinicians. Their size, position, and vascularity make successful surgical reaction impossible. Attempts at resection produce only temporary relief of symptoms and cause further disfigurement. Large AVMs give rise to pain, swelling, and distal ischaemia, can erode bone, and give rise to life-threatening hemorrhage, and a massive left or right shunt causes high-output cardiac failure and death. Ten patients (age range, 5-50 years; mean 26 years) have massive AVMs giving rise to high-output cardiac failure (26-28 liters). These patients (seven male, three female), have undergone a total of 43 embolization procedures. The advent of nonionic contrast media, digital subtraction angiography, steel coils, and balloons allows us to successfully treat these patients who until recently were condemned to die in high-output cardiac failure

  18. Farm-Level Determinants of output Commercialization:

    African Journals Online (AJOL)

    MARC-AB

    Ethiopian Institute of Agricultural Research. አኀፅሮተ- ... haricot bean output commercialization among smallholder farmers in moisture-stress areas of ..... the American Agricultural Economics Association Annual Meeting, Orlando, Florida, July.

  19. Endogenous Money, Output and Prices in India

    OpenAIRE

    Das, Rituparna

    2009-01-01

    This paper proposes to quantify the macroeconometric relationships among the variables broad money, lending by banks, price, and output in India using simultaneous equations system keeping in view the issue of endogeneity.

  20. Scintillation camera with improved output means

    International Nuclear Information System (INIS)

    Lange, K.; Wiesen, E.J.; Woronowicz, E.M.

    1978-01-01

    In a scintillation camera system, the output pulse signals from an array of photomultiplier tubes are coupled to the inputs of individual preamplifiers. The preamplifier output signals are coupled to circuitry for computing the x and y coordinates of the scintillations. A cathode ray oscilloscope is used to form an image corresponding with the pattern in which radiation is emitted by a body. Means for improving the uniformity and resolution of the scintillations are provided. The means comprise biasing means coupled to the outputs of selected preamplifiers so that output signals below a predetermined amplitude are not suppressed and signals falling within increasing ranges of amplitudes are increasingly suppressed. In effect, the biasing means make the preamplifiers non-linear for selected signal levels

  1. Input-output rearrangement of isolated converters

    DEFF Research Database (Denmark)

    Madsen, Mickey Pierre; Kovacevic, Milovan; Mønster, Jakob Døllner

    2015-01-01

    This paper presents a new way of rearranging the input and output of isolated converters. The new arrangement posses several advantages, as increased voltage range, higher power handling capabilities, reduced voltage stress and improved efficiency, for applications where galvanic isolation...

  2. Multiple Input - Multiple Output (MIMO) SAR

    Data.gov (United States)

    National Aeronautics and Space Administration — This effort will research and implement advanced Multiple-Input Multiple-Output (MIMO) Synthetic Aperture Radar (SAR) techniques which have the potential to improve...

  3. Neonatal Hemodynamics: From Developmental Physiology to Comprehensive Monitoring

    Directory of Open Access Journals (Sweden)

    Sabine L. Vrancken

    2018-04-01

    Full Text Available Maintenance of neonatal circulatory homeostasis is a real challenge, due to the complex physiology during postnatal transition and the inherent immaturity of the cardiovascular system and other relevant organs. It is known that abnormal cardiovascular function during the neonatal period is associated with increased risk of severe morbidity and mortality. Understanding the functional and structural characteristics of the neonatal circulation is, therefore, essential, as therapeutic hemodynamic interventions should be based on the assumed underlying (pathophysiology. The clinical assessment of systemic blood flow (SBF by indirect parameters, such as blood pressure, capillary refill time, heart rate, urine output, and central-peripheral temperature difference is inaccurate. As blood pressure is no surrogate for SBF, information on cardiac output and systemic vascular resistance should be obtained in combination with an evaluation of end organ perfusion. Accurate and reliable hemodynamic monitoring systems are required to detect inadequate tissue perfusion and oxygenation at an early stage before this result in irreversible damage. Also, the hemodynamic response to the initiated treatment should be re-evaluated regularly as changes in cardiovascular function can occur quickly. New insights in the understanding of neonatal cardiovascular physiology are reviewed and several methods for current and future neonatal hemodynamic monitoring are discussed.

  4. Recommended methods for evaluating the benefits of ECUT Program outputs. [Energy Conversion and Utilization

    Energy Technology Data Exchange (ETDEWEB)

    Levine, L.O.; Winter, C.

    1986-03-01

    This study was conducted to define and develop techniques that could be used to assess the complete spectrum of positive effects resulting from the Energy Conversion and Utilization Technologies (ECUT) Program activities. These techniques could then be applied to measure the benefits from past ECUT outputs. In addition, the impact of future ECUT outputs could be assessed as part of an ongoing monitoring process, after sufficient time has elapsed to allow their impacts to develop.

  5. A randomized controlled trial of levosimendan to reduce mortality in high-risk cardiac surgery patients (CHEETAH): Rationale and design.

    Science.gov (United States)

    Zangrillo, Alberto; Alvaro, Gabriele; Pisano, Antonio; Guarracino, Fabio; Lobreglio, Rosetta; Bradic, Nikola; Lembo, Rosalba; Gianni, Stefano; Calabrò, Maria Grazia; Likhvantsev, Valery; Grigoryev, Evgeny; Buscaglia, Giuseppe; Pala, Giovanni; Auci, Elisabetta; Amantea, Bruno; Monaco, Fabrizio; De Vuono, Giovanni; Corcione, Antonio; Galdieri, Nicola; Cariello, Claudia; Bove, Tiziana; Fominskiy, Evgeny; Auriemma, Stefano; Baiocchi, Massimo; Bianchi, Alessandro; Frontini, Mario; Paternoster, Gianluca; Sangalli, Fabio; Wang, Chew-Yin; Zucchetti, Maria Chiara; Biondi-Zoccai, Giuseppe; Gemma, Marco; Lipinski, Michael J; Lomivorotov, Vladimir V; Landoni, Giovanni

    2016-07-01

    Patients undergoing cardiac surgery are at risk of perioperative low cardiac output syndrome due to postoperative myocardial dysfunction. Myocardial dysfunction in patients undergoing cardiac surgery is a potential indication for the use of levosimendan, a calcium sensitizer with 3 beneficial cardiovascular effects (inotropic, vasodilatory, and anti-inflammatory), which appears effective in improving clinically relevant outcomes. Double-blind, placebo-controlled, multicenter randomized trial. Tertiary care hospitals. Cardiac surgery patients (n = 1,000) with postoperative myocardial dysfunction (defined as patients with intraaortic balloon pump and/or high-dose standard inotropic support) will be randomized to receive a continuous infusion of either levosimendan (0.05-0.2 μg/[kg min]) or placebo for 24-48 hours. The primary end point will be 30-day mortality. Secondary end points will be mortality at 1 year, time on mechanical ventilation, acute kidney injury, decision to stop the study drug due to adverse events or to start open-label levosimendan, and length of intensive care unit and hospital stay. We will test the hypothesis that levosimendan reduces 30-day mortality in cardiac surgery patients with postoperative myocardial dysfunction. This trial is planned to determine whether levosimendan could improve survival in patients with postoperative low cardiac output syndrome. The results of this double-blind, placebo-controlled randomized trial may provide important insights into the management of low cardiac output in cardiac surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Magnetic resonance imaging of implantable cardiac rhythm devices at 3.0 tesla.

    Science.gov (United States)

    Gimbel, J Rod

    2008-07-01

    A relaxation of the prohibition of scanning cardiac rhythm device patients is underway, largely because of the growing experience of safe scanning events at 1.5T. Magnetic resonance imaging (MRI) at 3T is becoming more common and may pose a different risk profile and outcome of MRI of cardiac device patients. No restrictions were placed on pacemaker dependency, region scanned, device type, or manufacturer. Sixteen scans at 3T were performed with an electrophysiologist present on 14 patients with a variety of devices from various manufacturers. An "MRI-S" strategy was used. Multimodal monitoring was required. Device interrogation was performed prior to, immediately after, and 1-3 months after the MRI. For nonpacemaker-dependent device patients, attempts were made to turn all device features off (with OOO programming the goal) conceptually rendering the device "invisible." In pacemaker-dependent patients, the device was programmed to asynchronous mode at highest output for the duration of the scan with the goal of rendering the device conceptually "invulnerable" to MRI effects. The specific absorption rate (SAR) was limited to 2W/kg. All patients were successfully scanned. No arrhythmias were noted. No significant change in the programmed parameters, pacing thresholds, sensing, impedance, or battery parameters was noted. The insertable loop recorder (ILR) recorded prolonged artifactual asystole during MRI. One patient noted chest burning during the scan. Device patients may undergo carefully tailored 3T MRI scans when pre-MRI reprogramming of the device occurs in conjunction with extensive monitoring, supervision, and follow-up.

  7. Neonatal cardiac emergencies

    African Journals Online (AJOL)

    flow) or require intervention (surgical or catheter) within the first ... Cardiac. History. Risk factors, e.g. meconium-stained liquor, prematurity, ... 'snowman' sign for supracardiac total anomalous pulmonary venous drainage (TAPVD), cardiomegaly with plethora for ... central cyanosis and on auscultation you hear no murmurs.

  8. Comparative cardiac imaging

    International Nuclear Information System (INIS)

    Brundage, B.H.

    1990-01-01

    This book is designed to compare all major cardiac imaging techniques. All major imaging techniques - including conventional angiography, digital angiography, echocardiography and Doppler imaging, conventional radioisotope techniques, computed tomography, and magnetic resonance imaging - are covered in this text as they apply to the major cardiovascular disorders. There is brief coverage of positron emission tomography and an extensive presentation of ultrafast computed tomography

  9. Advanced Cardiac Life Support.

    Science.gov (United States)

    Kirkwood Community Coll., Cedar Rapids, IA.

    This document contains materials for an advanced college course in cardiac life support developed for the State of Iowa. The course syllabus lists the course title, hours, number, description, prerequisites, learning activities, instructional units, required text, six references, evaluation criteria, course objectives by units, course…

  10. Cardiac Pacemakers; Marcapasos Cardiacos

    Energy Technology Data Exchange (ETDEWEB)

    Fiandra, O [Universidad de la Republica, Facultad de Maedicina, Departamento de Cardiologia, Montevideo(Uruguay); Espasandin, W [Universidad de la Republica, Facultad de Medicina, Departamento de Cirugia Cardiaca, Montevideo (Uruguay); Fiandra, H [Instituto Nacional de Cirugia Cardiaca, Departamento de Hemodinamia y Marcapasos, Montevideo (Uruguay); and others

    1984-07-01

    A complete survey of physiological biophysical,clinical and engineering aspects of cardiac facing,including the history and an assessment of possible future developments.Among the topics studied are: pacemakers, energy search, heart stimulating with pacemakers ,mathematical aspects of the electric cardio stimulation chronic, pacemaker implants,proceeding,treatment and control.

  11. Nonexercise cardiac stress testing

    International Nuclear Information System (INIS)

    Vacek, J.L.; Baldwin, T.

    1989-01-01

    Many patients who require evaluation for coronary artery disease are unable to undergo exercise stress testing because of physiologic or psychological limitations. Drs Vacek and Baldwin describe three alternative methods for assessment of cardiac function in these patients, all of which have high levels of diagnostic sensitivity and specificity. 23 references

  12. Cardiac magnetic resonance imaging

    African Journals Online (AJOL)

    2011-03-06

    Mar 6, 2011 ... Cardiac magnetic resonance imaging. Cardiovascular magnetic resonance imaging is becoming a routine diagnostic technique. BRUCE s sPOTTiswOOdE, PhD. MRC/UCT Medical Imaging Research Unit, University of Cape Town, and Division of Radiology, Stellenbosch University. Bruce Spottiswoode ...

  13. Predicting Output Power for Nearshore Wave Energy Harvesting

    Directory of Open Access Journals (Sweden)

    Henock Mamo Deberneh

    2018-04-01

    Full Text Available Energy harvested from a Wave Energy Converter (WEC varies greatly with the location of its installation. Determining an optimal location that can result in maximum output power is therefore critical. In this paper, we present a novel approach to predicting the output power of a nearshore WEC by characterizing ocean waves using floating buoys. We monitored the movement of the buoys using an Arduino-based data collection module, including a gyro-accelerometer sensor and a wireless transceiver. The collected data were utilized to train and test prediction models. The models were developed using machine learning algorithms: SVM, RF and ANN. The results of the experiments showed that measurements from the data collection module can yield a reliable predictor of output power. Furthermore, we found that the predictors work better when the regressors are combined with a classifier. The accuracy of the proposed prediction model suggests that it could be extremely useful in both locating optimal placement for wave energy harvesting plants and designing the shape of the buoys used by them.

  14. Capabilities of infrared weld monitor

    Energy Technology Data Exchange (ETDEWEB)

    Sanders, P.G.; Keske, J.S.; Leong, K.H.; Kornecki, G.

    1997-11-01

    A non-obtrusive pre-aligned, solid-state device has been developed to monitor the primary infrared emissions during laser welding. The weld monitor output is a 100-1000 mV signal that depends on the beam power and weld characteristics. The DC level of this signal is related to weld penetration, while AC portions of the output can be correlated with surface irregularities and part misalignment or contamination. Changes in DC behavior are also noted for both full and deep penetration welds. Full penetration welds are signified by an abrupt reduction in the weld monitor output. Bead on plate welds were made on steel, aluminum, and magnesium with both a CW CO{sub 2} laser and a pulsed Nd:YAG laser to explore the relationships between the weld characteristics and the weld monitor output.

  15. Establishing a clinical cardiac MRI service

    International Nuclear Information System (INIS)

    O'Regan, D.P.; Schmitz, S.A.

    2006-01-01

    After several years of research development cardiovascular MRI has evolved into a widely accepted clinical tool. It offers important diagnostic and prognostic information for a variety of clinical indications, which include ischaemic heart disease, cardiomyopathies, valvular dysfunction and congenital heart disorders. It is a safe non-invasive technique that employs a variety of imaging sequences optimized for temporal or spatial resolution, tissue-specific contrast, flow quantification or angiography. Cardiac MRI offers specific advantages over conventional imaging techniques for a significant number of patients. The demand for cardiac MRI studies from cardiothoracic surgeons, cardiologists and other referrers is likely to continue to rise with pressure for more widespread local service provision. Setting up a cardiac MRI service requires careful consideration regarding funding issues and how it will be integrated with existing service provision. The purchase of cardiac phased array coils, monitoring equipment and software upgrades must also be considered, as well as the training needs of those involved. The choice of appropriate imaging protocols will be guided by operator experience, clinical indication and equipment capability, and is likely to evolve as the service develops. Post-processing and offline analysis form a significant part of the time taken to report studies and an efficient method of providing quantitative reports is an important requirement. Collaboration between radiologists and cardiologists is needed to develop a successful service and multi-disciplinary meetings are key component of this. This review will explore these issues from our perspective of a new clinical cardiac MRI service operating over its first year in a teaching hospital imaging department

  16. Impact of extracorporeal blood flow rate on blood pressure, pulse rate and cardiac output during haemodialysis

    DEFF Research Database (Denmark)

    Schytz, Philip Andreas; Mace, Maria Lerche; Soja, Anne Merete Boas

    2015-01-01

    BACKGROUND: If blood pressure (BP) falls during haemodialysis (HD) [intradialytic hypotension (IDH)] a common clinical practice is to reduce the extracorporeal blood flow rate (EBFR). Consequently the efficacy of the HD (Kt/V) is reduced. However, only very limited knowledge on the effect...

  17. Pulmonary tissue volume, cardiac output, and diffusing capacity in sustained microgravity

    Science.gov (United States)

    Verbanck, S.; Larsson, H.; Linnarsson, D.; Prisk, G. K.; West, J. B.; Paiva, M.

    1997-01-01

    In microgravity (microG) humans have marked changes in body fluids, with a combination of an overall fluid loss and a redistribution of fluids in the cranial direction. We investigated whether interstitial pulmonary edema develops as a result of a headward fluid shift or whether pulmonary tissue fluid volume is reduced as a result of the overall loss of body fluid. We measured pulmonary tissue volume (Vti), capillary blood flow, and diffusing capacity in four subjects before, during, and after 10 days of exposure to microG during spaceflight. Measurements were made by rebreathing a gas mixture containing small amounts of acetylene, carbon monoxide, and argon. Measurements made early in flight in two subjects showed no change in Vti despite large increases in stroke volume (40%) and diffusing capacity (13%) consistent with increased pulmonary capillary blood volume. Late in-flight measurements in four subjects showed a 25% reduction in Vti compared with preflight controls (P volume, to the extent that it was no longer significantly different from preflight control. Diffusing capacity remained elevated (11%; P pulmonary perfusion and pulmonary capillary blood volume, interstitial pulmonary edema does not result from exposure to microG.

  18. Effect of atropine, norepinephrine and phenylephrine on cerebral oxygenation and cardiac output during anesthesia.

    NARCIS (Netherlands)

    Kalmar, A.F.; Poterman, Marieke; Mooyaart, E.A.; Struys, Michel; Scheeren, Thomas

    2012-01-01

    Background:  Induction of general anesthesia often induces unwanted hypotension which is commonly treated with vasoactive medication to restore an appropriate blood pressure. Phenylephrine, norepinephrine and atropine are commonly used agents for this purpose with different physiological effects.

  19. Evaluation of cerebral electrical activity and cardiac output after patent ductus arteriosus ligation in preterm infants.

    LENUS (Irish Health Repository)

    Leslie, A T F S

    2013-11-01

    To characterize and investigate the relationship between systemic blood flow and pre- and postoperative cerebral electrical activity in preterm neonates undergoing patent ductus arteriosus (PDA) ligation.

  20. Cardiac output determined by echocardiography in patients with cirrhosis: comparison with the indicator dilution technique

    DEFF Research Database (Denmark)

    Andersen, Ulrik B; Møller, Søren; Bendtsen, Flemming

    2003-01-01

    technique (CO(I)). METHODS: Twelve patients with cirrhosis were studied. CO(d) was measured as the spatial mean velocity of the left ventricular outflow tract, multiplied by the cross-sectional area and the heart rate. CO(I) was determined by the standard indicator dilution technique after injection of 125I...... albumin and 99mTc albumin into the right atrium and subsequent sampling from the femoral artery. RESULTS: The mean CO(d) and CO(I) were similar (7.20 vs 7.15 l/min, NS). A highly significant correlation was present between CO(d) and CO(I) (r = 0.86, P

  1. Measurements of cardiac output obtained with transesophageal echocardiography and pulmonary artery thermodilution are not interchangeable

    DEFF Research Database (Denmark)

    Møller-Sørensen, H; Graeser, K; Hansen, K L

    2014-01-01

    was placed in the following successive positions: supine, head-down tilt, head-up tilt, supine, supine with phenylephrine administration, pace heart rate 80 beats per minute (bpm), pace heart rate 110 bpm. TEE CO and PAC CO were measured simultaneously. The agreement was analysed by Bland-Altman plots...

  2. Non-invasive measurement of cardiac output by Finometer in patients with cirrhosis

    DEFF Research Database (Denmark)

    Kaltoft, N; Hobolth, L; Møller, S

    2010-01-01

    .6 [3.9;9.7] l min(-1) (mean +/- SD [range]) compared to mean CO(F) of 7.2 +/- 2.3 [3.1;11.9] l min(-1). There was a mean difference between CO(F) and CO(I) of 1.0 +/- 1.8 [-2.1;4.0] l min(-1) and 95% confidence interval of [0.2;1.8], P...-blockade, mean DeltaCO(I) was 1.6 +/- 1.4 [-0.1;3.3] l min(-1) compared to mean DeltaCO(F) of 1.9 +/- 1.3 [0.4;3.8] l min(-1). Mean difference between DeltaCO(F) and DeltaCO(I) was 0.3 +/- 0.3 [-0.2;0.7] l min(-1) with a 95% confidence interval of [-0.1;0.6], P = 0.11. Compared with invasive measurements...

  3. Techniques of cardiac output measurement during liver transplantation: arterial pulse wave versus thermodilution

    DEFF Research Database (Denmark)

    Nissen, P.; Lieshout, J.J. van; Novovic, S.

    2009-01-01

    reperfusion)-without the detection of any significant difference between the 2 estimates of CO. TDCO ranged from 2.3 to 17.2 L/minute, and the bias (the mean difference between MCO and TDCO) prior to calibration was -0.4 +/- 1.6 L/minute (mean +/- standard deviation; 1309 paired measurements; 95% limits...... of agreement: -3.4 to 2.6 L/minute). After calibration of the first determined MCO by the simultaneously determined TDCO, the bias was 0.1 +/- 1.5 L/minute, with 57% (n = 744) of the comparisons being less than 1 L/minute and 35% (n = 453) being less than 0.5 L/minute; this was independent of the level of CO...

  4. System theory in industrial patient monitoring: an overview.

    Science.gov (United States)

    Baura, G D

    2004-01-01

    Patient monitoring refers to the continuous observation of repeating events of physiologic function to guide therapy or to monitor the effectiveness of interventions, and is used primarily in the intensive care unit and operating room. Commonly processed signals are the electrocardiogram, intraarterial blood pressure, arterial saturation of oxygen, and cardiac output. To this day, the majority of physiologic waveform processing in patient monitors is conducted using heuristic curve fitting. However in the early 1990s, a few enterprising engineers and physicians began using system theory to improve their core processing. Applications included improvement of signal-to-noise ratio, either due to low signal levels or motion artifact, and improvement in feature detection. The goal of this mini-symposium is to review the early work in this emerging field, which has led to technologic breakthroughs. In this overview talk, the process of system theory algorithm research and development is discussed. Research for industrial monitors involves substantial data collection, with some data used for algorithm training and the remainder used for validation. Once the algorithms are validated, they are translated into detailed specifications. Development then translates these specifications into DSP code. The DSP code is verified and validated per the Good Manufacturing Practices mandated by FDA.

  5. The Danish Cardiac Rehabilitation Database.

    Science.gov (United States)

    Zwisler, Ann-Dorthe; Rossau, Henriette Knold; Nakano, Anne; Foghmar, Sussie; Eichhorst, Regina; Prescott, Eva; Cerqueira, Charlotte; Soja, Anne Merete Boas; Gislason, Gunnar H; Larsen, Mogens Lytken; Andersen, Ulla Overgaard; Gustafsson, Ida; Thomsen, Kristian K; Boye Hansen, Lene; Hammer, Signe; Viggers, Lone; Christensen, Bo; Kvist, Birgitte; Lindström Egholm, Cecilie; May, Ole

    2016-01-01

    The Danish Cardiac Rehabilitation Database (DHRD) aims to improve the quality of cardiac rehabilitation (CR) to the benefit of patients with coronary heart disease (CHD). Hospitalized patients with CHD with stenosis on coronary angiography treated with percutaneous coronary intervention, coronary artery bypass grafting, or medication alone. Reporting is mandatory for all hospitals in Denmark delivering CR. The database was initially implemented in 2013 and was fully running from August 14, 2015, thus comprising data at a patient level from the latter date onward. Patient-level data are registered by clinicians at the time of entry to CR directly into an online system with simultaneous linkage to other central patient registers. Follow-up data are entered after 6 months. The main variables collected are related to key outcome and performance indicators of CR: referral and adherence, lifestyle, patient-related outcome measures, risk factor control, and medication. Program-level online data are collected every third year. Based on administrative data, approximately 14,000 patients with CHD are hospitalized at 35 hospitals annually, with 75% receiving one or more outpatient rehabilitation services by 2015. The database has not yet been running for a full year, which explains the use of approximations. The DHRD is an online, national quality improvement database on CR, aimed at patients with CHD. Mandatory registration of data at both patient level as well as program level is done on the database. DHRD aims to systematically monitor the quality of CR over time, in order to improve the quality of CR throughout Denmark to benefit patients.

  6. Maternal cardiac metabolism in pregnancy

    Science.gov (United States)

    Liu, Laura X.; Arany, Zolt

    2014-01-01

    Pregnancy causes dramatic physiological changes in the expectant mother. The placenta, mostly foetal in origin, invades maternal uterine tissue early in pregnancy and unleashes a barrage of hormones and other factors. This foetal ‘invasion’ profoundly reprogrammes maternal physiology, affecting nearly every organ, including the heart and its metabolism. We briefly review here maternal systemic metabolic changes during pregnancy and cardiac metabolism in general. We then discuss changes in cardiac haemodynamic during pregnancy and review what is known about maternal cardiac metabolism during pregnancy. Lastly, we discuss cardiac diseases during pregnancy, including peripartum cardiomyopathy, and the potential contribution of aberrant cardiac metabolism to disease aetiology. PMID:24448314

  7. Sudden cardiac arrest as a rare presentation of myxedema coma: case report.

    Science.gov (United States)

    Salhan, Divya; Sapkota, Deepak; Verma, Prakash; Kandel, Saroj; Abdulfattah, Omar; Lixon, Antony; Zwenge, Deribe; Schmidt, Frances

    2017-01-01

    Myxedema coma is a decompensated hypothyroidism which occurs due to long-standing, undiagnosed, or untreated hypothyroidism. Untreated hypothyroidism is known to affect almost all organs including the heart. It is associated with a decrease in cardiac output, stroke volume due to decreased myocardial contractility, and an increase in systemic vascular resistance. It can cause cardiac arrhythmias and the most commonly seen conduction abnormalities are sinus bradycardia, heart block, ventricular tachycardia, and torsade de pointes. The authors report a case of an elderly man who presented with sudden cardiac arrest and myxedema coma and who was successfully revived.

  8. Coi-wiz: An interactive computer wizard for analyzing cardiac optical signals.

    Science.gov (United States)

    Yuan, Xiaojing; Uyanik, Ilyas; Situ, Ning; Xi, Yutao; Cheng, Jie

    2009-01-01

    A number of revolutionary techniques have been developed for cardiac electrophysiology research to better study the various arrhythmia mechanisms that can enhance ablating strategies for cardiac arrhythmias. Once the three-dimensional high resolution cardiac optical imaging data is acquired, it is time consuming to manually go through them and try to identify the patterns associated with various arrhythmia symptoms. In this paper, we present an interactive computer wizard that helps cardiac electrophysiology researchers to visualize and analyze the high resolution cardiac optical imaging data. The wizard provides a file interface that accommodates different file formats. A series of analysis algorithms output waveforms, activation and action potential maps after spatial and temporal filtering, velocity field and heterogeneity measure. The interactive GUI allows the researcher to identify the region of interest in both the spatial and temporal domain, thus enabling them to study different heart chamber at their choice.

  9. Residual gravimetric method to measure nebulizer output.

    Science.gov (United States)

    Vecellio None, Laurent; Grimbert, Daniel; Bordenave, Joelle; Benoit, Guy; Furet, Yves; Fauroux, Brigitte; Boissinot, Eric; De Monte, Michele; Lemarié, Etienne; Diot, Patrice

    2004-01-01

    The aim of this study was to assess a residual gravimetric method based on weighing dry filters to measure the aerosol output of nebulizers. This residual gravimetric method was compared to assay methods based on spectrophotometric measurement of terbutaline (Bricanyl, Astra Zeneca, France), high-performance liquid chromatography (HPLC) measurement of tobramycin (Tobi, Chiron, U.S.A.), and electrochemical measurements of NaF (as defined by the European standard). Two breath-enhanced jet nebulizers, one standard jet nebulizer, and one ultrasonic nebulizer were tested. Output produced by the residual gravimetric method was calculated by weighing the filters both before and after aerosol collection and by filter drying corrected by the proportion of drug contained in total solute mass. Output produced by the electrochemical, spectrophotometric, and HPLC methods was determined after assaying the drug extraction filter. The results demonstrated a strong correlation between the residual gravimetric method (x axis) and assay methods (y axis) in terms of drug mass output (y = 1.00 x -0.02, r(2) = 0.99, n = 27). We conclude that a residual gravimetric method based on dry filters, when validated for a particular agent, is an accurate way of measuring aerosol output.

  10. Output characteristics of Stirling thermoacoustic engine

    International Nuclear Information System (INIS)

    Sun Daming; Qiu Limin; Wang Bo; Xiao Yong; Zhao Liang

    2008-01-01

    A thermoacoustic engine (TE), which converts thermal energy into acoustic power by the thermoacoustic effect, shows several advantages due to the absence of moving parts, such as high reliability and long lifetime associated with reduced manufacturing costs. Power output and efficiency are important criteria of the performance of a TE. In order to increase the acoustic power output and thermal efficiency of a Stirling TE, the acoustic power distribution in the engine is studied with the variable load method. It is found that the thermal efficiency is independent of the output locations along the engine under the same acoustic power output. Furthermore, when the pressure ratio is kept constant at one location along the TE, it is beneficial to increasing the thermal efficiency by exporting more acoustic power. With nitrogen of 2.5 MPa as working gas and the pressure ratio at the compliance of 1.20 in the experiments, the acoustic power is measured at the compliance and the resonator simultaneously. The maximum power output, thermal efficiency and exergy efficiency reach 390.0 W, 11.2% and 16.0%, which are increased by 51.4%, 24.4% and 19.4%, respectively, compared to those with a single R-C load with 750 ml reservoir at the compliance. This research will be instructive for increasing the efficiency and making full use of the acoustic energy of a TE

  11. Estimation of international output-energy relation. Effects of alternative output measures

    International Nuclear Information System (INIS)

    Shrestha, R.M.

    2000-01-01

    This paper analyzes the output-energy relationship with alternative measures of output and energy. Our analysis rejects the hypothesis of non-diminishing returns to energy consumption when GDP at purchasing power parities is used as the output measure unlike the case with GNP at market exchange rates. This finding also holds when energy input includes the usage of both commercial and traditional fuels. 13 refs

  12. From Static Output Feedback to Structured Robust Static Output Feedback: A Survey

    OpenAIRE

    Sadabadi , Mahdieh ,; Peaucelle , Dimitri

    2016-01-01

    This paper reviews the vast literature on static output feedback design for linear time-invariant systems including classical results and recent developments. In particular, we focus on static output feedback synthesis with performance specifications, structured static output feedback, and robustness. The paper provides a comprehensive review on existing design approaches including iterative linear matrix inequalities heuristics, linear matrix inequalities with rank constraints, methods with ...

  13. Wireless cardiac action potential transmission with ultrasonically inserted silicon microprobes

    International Nuclear Information System (INIS)

    Shen, C J; Ramkumar, A; Lal, A; Gilmour, R F Jr

    2011-01-01

    This paper reports on the integration of ultrasonically inserted horn-shaped cardiac probes with wireless transmission of 3D cardiac action potential measurement for applications in ex vivo preparations such as monitoring the onset of ventricular fibrillation. Ultrasonically inserted silicon horn probes permit reduced penetration force during insertion, allowing silicon, a brittle material, to penetrate cardiac tissue. The probes also allow recording from multiple sites that are lithographically defined. An application-specific integrated circuit has been designed with a 40 dB amplifying stage and a frequency modulating oscillator at 95 MHz to wirelessly transmit the recorded action potentials. This ultrasonically inserted microprobe wireless system demonstrates the initial results in wireless monitoring of 3D action potential propagation, and the extraction of parameters of interest including the action potential duration and diastolic interval

  14. 47. A cardiac center experience with Brugada syndrome who survived sudden cardiac death

    Directory of Open Access Journals (Sweden)

    I. Suliman

    2016-07-01

    Full Text Available Brugada syndrome is a heritable arrhythmia syndrome that is characterized by an electrocardiographic pattern consisting of coved-type ST-segment elevation (2 mm followed by a negative T wave in the right precordial leads, V1 through V3 (often referred to as type 1 Brugada electrocardiographic pattern, here we describe 3 cases of Brugada who survived sudden cardiac death (SCD cardiac center experience with survived Brugada syndrome patients – case series. First Case: The Father 45 years old male, presented in 2005 after involvement in unprovoked motor vehicle accident, the patient was the driver who lost consciousness and rushed to the hospital. On arrival to our ER and putting the patient on the bed, the ER doctor observed a brief episode of VF on the monitor. The patient was taken to the catheterization Lab , his coronaries were normal. The diagnosis of Brugada was established and the patient received a defibrillator. At That Time all family members were screened and were negative. Second Case: The Son of the first patient 5 years later his 23 years old male rushed to our ER after he lost consciousness, he was passenger in the car of his friend. Third Case: The pilot A military pilot aged a male 35 years old was in very good health when he lost consciousness and brought to the hospital after resuscitation in 2005. He had full invasive cardiac evaluation, subsequently he received a defibrillator in the same admission period, till 2015 he is doing fine. Brugada syndrome is associated with high tendency for sudden cardiac death. In our three cases the first clinical presentation was survived sudden cardiac death (SCD and all three male patients survived. We did not encounter a female patient who survived sudden cardiac death.

  15. Problems in Modelling Charge Output Accelerometers

    Directory of Open Access Journals (Sweden)

    Tomczyk Krzysztof

    2016-12-01

    Full Text Available The paper presents major issues associated with the problem of modelling change output accelerometers. The presented solutions are based on the weighted least squares (WLS method using transformation of the complex frequency response of the sensors. The main assumptions of the WLS method and a mathematical model of charge output accelerometers are presented in first two sections of this paper. In the next sections applying the WLS method to estimation of the accelerometer model parameters is discussed and the associated uncertainties are determined. Finally, the results of modelling a PCB357B73 charge output accelerometer are analysed in the last section of this paper. All calculations were executed using the MathCad software program. The main stages of these calculations are presented in Appendices A−E.

  16. Cardiac fusion and complex congenital cardiac defects in thoracopagus twins: diagnostic value of cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of); Park, Jeong-Jun [University of Ulsan College of Medicine, Asan Medical Center, Department of Pediatric Cardiac Surgery, Seoul (Korea, Republic of); Kim, Ellen Ai-Rhan [University of Ulsan College of Medicine, Asan Medical Center, Division of Neonatology, Department of Pediatrics, Seoul (Korea, Republic of); Won, Hye-Sung [University of Ulsan College of Medicine, Asan Medical Center, Department of Obstetrics and Gynecology, Seoul (Korea, Republic of)

    2014-09-15

    Most thoracopagus twins present with cardiac fusion and associated congenital cardiac defects, and assessment of this anatomy is of critical importance in determining patient care and outcome. Cardiac CT with electrocardiographic triggering provides an accurate and quick morphological assessment of both intracardiac and extracardiac structures in newborns, making it the best imaging modality to assess thoracopagus twins during the neonatal period. In this case report, we highlight the diagnostic value of cardiac CT in thoracopagus twins with an interatrial channel and complex congenital cardiac defects. (orig.)

  17. Reliability and Energy Output of Bifacial Modules

    Energy Technology Data Exchange (ETDEWEB)

    Van Aken, B.B.; Jansen, M.J.; Dekker, N.J.J. [ECN Solar Energy, Petten (Netherlands)

    2013-06-15

    Although flash tests under standard test conditions yields lower power due to transmittance of the back sheet, bifacial modules are expected to outperform their monofacial equivalents in terms of yearly energy output in the field. We compare flash tests for bifacial modules with and without a light scattering panel directly behind the modules: 3% more power output is obtained. We also report on the damp-heat reliability of modules with transparent back sheet. Finally we will present the results of an outdoor study comparing modules with transparent back sheet and modules with state-of-the-art AR coating on the front glass.

  18. Explaining output volatility: The case of taxation

    DEFF Research Database (Denmark)

    Posch, Olaf

    the second moment of output growth rates without (long-run) effects on the first moment. Taking the model to the data, we exploit observed heterogeneity patterns to estimate effects of tax rates on macro volatility using panel estimation, explicitly modeling the unobserved variance process. We find a strong......This paper studies the effects of taxation on output volatility in OECD countries to shed light on the sources of observed heterogeneity over time and across countries. To this end, we derive tax effects on macro aggregates in a stochastic neoclassical model. As a result, taxes are shown to affect...... positive effects....

  19. The light output of BGO crystals

    International Nuclear Information System (INIS)

    Gong Zhufang; Ma Wengan; Lin Zhirong; Wang Zhaomin; Xu Zhizong; Fan Yangmei

    1987-01-01

    The dependence of light output on the surface treatment of BGO crystals has been tested. The results of experiments and Monte Carlo calculation indicate that for a tapered BGO crystal the best way to improve the uniformity and the energy resolution and to obtain higher light output is roughing the surface coupled to photomultiplier tube. The authors also observed that different wrapping method can effect its uniformity and resolutoin. Monte Carlo calculation indicates that the higher one of the 'double peaks' is the photoelectron peak of γ rays

  20. e-Coaching for Intensive Cardiac Rehabilitation : a Requirement Analysis

    NARCIS (Netherlands)

    Nooitgedagt, A.; Beun, R.J.; Dignum, F.P.M.

    2017-01-01

    In this paper, the rationale and requirements are presented for an e-coaching system in the domain of intensive cardiac rehabilitation. It is argued that there is a need for a personalized program with close monitoring of the patient based on medical needs and needed lifestyle changes in a setting

  1. A patient self-assessment tool for cardiac rehabilitation.

    Science.gov (United States)

    Phelan, C; Finnell, M D; Mottla, K A

    1989-01-01

    A patient self-assessment tool was designed, tested, and implemented to promote cardiac-specific data collection, based on Gordon's Functional Health Patterns, to maximize patient/family involvement in determining a plan of care, and to streamline primary nurses' documentation requirements. Retrospective and concurrent chart reviews provided data for quality assurance monitoring. The results of the monitoring demonstrated that the self-assessment tool markedly improved the patient-specific data base.

  2. Socially differentiated cardiac rehabilitation

    DEFF Research Database (Denmark)

    Meillier, Lucette Kirsten; Nielsen, Kirsten Melgaard; Larsen, Finn Breinholt

    2012-01-01

    in recruitment and participation among low educated and socially vulnerable patients must be addressed to lower inequality in post-MI health. Our aim was to improve referral, attendance, and adherence rates among socially vulnerable patients by systematic screening and by offering a socially differentiated...... to a standard rehabilitation programme (SRP). If patients were identified as socially vulnerable, they were offered an extended version of the rehabilitation programme (ERP). Excluded patients were offered home visits by a cardiac nurse. Concordance principles were used in the individualised programme elements......%. Patients were equally distributed to the SRP and the ERP. No inequality was found in attendance and adherence among referred patients. Conclusions: It seems possible to overcome unequal referral, attendance, and adherence in cardiac rehabilitation by organisation of systematic screening and social...

  3. Ictal Cardiac Ryhthym Abnormalities.

    Science.gov (United States)

    Ali, Rushna

    2016-01-01

    Cardiac rhythm abnormalities in the context of epilepsy are a well-known phenomenon. However, they are under-recognized and often missed. The pathophysiology of these events is unclear. Bradycardia and asystole are preceded by seizure onset suggesting ictal propagation into the cortex impacting cardiac autonomic function, and the insula and amygdala being possible culprits. Sudden unexpected death in epilepsy (SUDEP) refers to the unanticipated death of a patient with epilepsy not related to status epilepticus, trauma, drowning, or suicide. Frequent refractory generalized tonic-clonic seizures, anti-epileptic polytherapy, and prolonged duration of epilepsy are some of the commonly identified risk factors for SUDEP. However, the most consistent risk factor out of these is an increased frequency of generalized tonic-clonic seizures (GTC). Prevention of SUDEP is extremely important in patients with chronic, generalized epilepsy. Since increased frequency of GTCS is the most consistently reported risk factor for SUDEP, effective seizure control is the most important preventive strategy.

  4. Fetal cardiac assessment

    International Nuclear Information System (INIS)

    Greene, K.R.

    1983-01-01

    The better understanding of fetal cardiovascular physiology coupled with improved technology for non-invasive study of the fetus now enable much more detailed assessment of fetal cardiac status than by heart rate alone. Even the latter, relatively simple, measurement contains much more information than was previously realized. It is also increasingly clear that no single measurement will provide the answer to all clinical dilemmas either on cardiac function or the welfare of the fetus as a whole. There are obvious clinical advantages in measuring several variables from one signal and the measurement of heart rate, heart rate variation and waveform from the ECG in labour is a potentially useful combination. Systolic time intervals or flow measurements could easily be added or used separately by combining real-time and Doppler ultrasound probes

  5. CSI cardiac prevent 2015

    OpenAIRE

    S Ramakrishnan; Manisha Kaushik

    2015-01-01

    The CSI Cardiac Prevent 2015 was held at Hotel Taj Palace, New Delhi, on September 25-27, 2015. The major challenge was to create interest among cardiologists and physicians on preventive cardiology, a neglected area. The theme of the conference was "Innovations in Heart Disease Prevention.′′ This conference included "CSI at WHF Roadmap Workshop, Inauguration Ceremony, scientific program, plenary sessions, Nursing/Dietician track, Industry Exhibition, Social Events," Great India blood pressur...

  6. Multifractality in Cardiac Dynamics

    Science.gov (United States)

    Ivanov, Plamen Ch.; Rosenblum, Misha; Stanley, H. Eugene; Havlin, Shlomo; Goldberger, Ary

    1997-03-01

    Wavelet decomposition is used to analyze the fractal scaling properties of heart beat time series. The singularity spectrum D(h) of the variations in the beat-to-beat intervals is obtained from the wavelet transform modulus maxima which contain information on the hierarchical distribution of the singularities in the signal. Multifractal behavior is observed for healthy cardiac dynamics while pathologies are associated with loss of support in the singularity spectrum.

  7. Integrative Cardiac Health Project

    Science.gov (United States)

    2014-10-01

    primary cardiac arrest. Circulation. 1998;97(2):155Y160. 8. Sesso HD, Lee IM, Gaziano JM, Rexrode KM, Glynn RJ, Buring JE. Maternal and paternal ...to signal transduction, inflammation, and host–pathogen interactions .27 Whole blood RNA isolation systems such as PAXgene accurately capture in vivo...the effect of healthy behaviors on leukocyte function and leukocyte–endothelium interactions that are important for cardiovascular health

  8. Neutron monitoring system

    International Nuclear Information System (INIS)

    Okido, Fumiyasu; Arita, Setsuo.

    1994-01-01

    The present invention concerns neutron monitoring for monitoring reactor power, and presents a generation state of abnormal signals by monitoring output signals from neutron sensors, judges abnormal signals at an excessively high level outputted from the sensors to a measuring operator or a reactor operator. That is, a threshold value judging means judges whether a sensor signal exceeds a predetermined threshold value or not. When it exceeds the value, recognition signals are outputted to a memory means. The memory means memorizes the times of input of the recognition signals on every period of interval signals outputted from a reference signal generation means. The memory content of the memory means and the previously inputted hysteresis of the sensor are compared and judged, to determine the extent of the degradation of the sensors and output the result of the judgement and hysteresis information to the display means. The input means accesses to the judging means and the memory means to retrieve and correct the content of the memory means and the hysteresis information inputted to the judging means. (I.S.)

  9. Molecular nuclear cardiac imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Soo; Paeng, Jin Chul [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    2004-04-01

    Molecular nuclear cardiac imaging has included Tc-99m Annexin imaging to visualize myocardial apoptosis, but is now usually associated with gene therapy and cell-based therapy. Cardiac gene therapy was not successful so far but cardiac reporter gene imaging was made possible using HSV-TK (herpes simplex virus thymidine kinase) and F-18 FHBG (fluoro-hydroxymethylbutyl guanine) or I-124 FIAU (fluoro-deoxyiodo-arabino-furanosyluracil). Gene delivery was performed by needle injection with or without catheter guidance. TK expression did not last longer than 2 weeks in myocardium. Cell-based therapy of ischemic heart or failing heart looks promising, but biodistribution and differentiation of transplanted cells are not known. Reporter genes can be transfected to the stem/progenitor cells and cells containing these genes can be transplanted to the recipients using catheter-based purging or injection. Repeated imaging should be available and if promoter are varied to let express reporter transgenes, cellular (trans)differentiation can be studied. NIS (sodium iodide symporter) or D2R receptor genes are promising in this aspect.

  10. Cardiac hybrid imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gaemperli, Oliver [University Hospital Zurich, Cardiac Imaging, Zurich (Switzerland); University Hospital Zurich, Nuclear Cardiology, Cardiovascular Center, Zurich (Switzerland); Kaufmann, Philipp A. [University Hospital Zurich, Cardiac Imaging, Zurich (Switzerland); Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland)

    2014-05-15

    Hybrid cardiac single photon emission computed tomography (SPECT)/CT imaging allows combined assessment of anatomical and functional aspects of cardiac disease. In coronary artery disease (CAD), hybrid SPECT/CT imaging allows detection of coronary artery stenosis and myocardial perfusion abnormalities. The clinical value of hybrid imaging has been documented in several subsets of patients. In selected groups of patients, hybrid imaging improves the diagnostic accuracy to detect CAD compared to the single imaging techniques. Additionally, this approach facilitates functional interrogation of coronary stenoses and guidance with regard to revascularization procedures. Moreover, the anatomical information obtained from CT coronary angiography or coronary artery calcium scores (CACS) adds prognostic information over perfusion data from SPECT. The use of cardiac hybrid imaging has been favoured by the dissemination of dedicated hybrid systems and the release of dedicated image fusion software, which allow simple patient throughput for hybrid SPECT/CT studies. Further technological improvements such as more efficient detector technology to allow for low-radiation protocols, ultra-fast image acquisition and improved low-noise image reconstruction algorithms will be instrumental to further promote hybrid SPECT/CT in research and clinical practice. (orig.)

  11. Cardiac Cachexia Syndrome

    Directory of Open Access Journals (Sweden)

    Teresa Raposo André

    2017-10-01

    Full Text Available Heart failure is a chronic, progressive, and incurable disease. Cardiac cachexia is a strong predictor of poor prognosis, regardless of other important variables. This review intends to gather evidence to enable recognition of cardiac cachexia, identification of early stages of muscle waste and sarcopenia, and improve identification of patients with terminal heart failure in need of palliative care, whose symptoms are no longer controlled by usual medical measures. The pathophysiology is complex and multifactorial. There are many treatment options to prevent or revert muscle waste and sarcopenia; although, these strategies are less effective in advanced stages of cardiac cachexia. In these final stages, symptomatic palliation plays an important role, focussing on the patient’s comfort and avoiding the ‘acute model’ treatment of aggressive, disproportionate, and inefficient care. In order to provide adequate care and attempt to prevent this syndrome, thus reducing its impact on healthcare, there should be improved communication between general practitioners, internal medicine physicians, cardiologists, and palliative care specialists since heart failure has an unforeseeable course and is associated with an increasing number of deaths and different levels of suffering.

  12. Cardiac tissue engineering

    Directory of Open Access Journals (Sweden)

    MILICA RADISIC

    2005-03-01

    Full Text Available We hypothesized that clinically sized (1-5 mm thick,compact cardiac constructs containing physiologically high density of viable cells (~108 cells/cm3 can be engineered in vitro by using biomimetic culture systems capable of providing oxygen transport and electrical stimulation, designed to mimic those in native heart. This hypothesis was tested by culturing rat heart cells on polymer scaffolds, either with perfusion of culture medium (physiologic interstitial velocity, supplementation of perfluorocarbons, or with electrical stimulation (continuous application of biphasic pulses, 2 ms, 5 V, 1 Hz. Tissue constructs cultured without perfusion or electrical stimulation served as controls. Medium perfusion and addition of perfluorocarbons resulted in compact, thick constructs containing physiologic density of viable, electromechanically coupled cells, in contrast to control constructs which had only a ~100 mm thick peripheral region with functionally connected cells. Electrical stimulation of cultured constructs resulted in markedly improved contractile properties, increased amounts of cardiac proteins, and remarkably well developed ultrastructure (similar to that of native heart as compared to non-stimulated controls. We discuss here the state of the art of cardiac tissue engineering, in light of the biomimetic approach that reproduces in vitro some of the conditions present during normal tissue development.

  13. Molecular nuclear cardiac imaging

    International Nuclear Information System (INIS)

    Lee, Dong Soo; Paeng, Jin Chul

    2004-01-01

    Molecular nuclear cardiac imaging has included Tc-99m Annexin imaging to visualize myocardial apoptosis, but is now usually associated with gene therapy and cell-based therapy. Cardiac gene therapy was not successful so far but cardiac reporter gene imaging was made possible using HSV-TK (herpes simplex virus thymidine kinase) and F-18 FHBG (fluoro-hydroxymethylbutyl guanine) or I-124 FIAU (fluoro-deoxyiodo-arabino-furanosyluracil). Gene delivery was performed by needle injection with or without catheter guidance. TK expression did not last longer than 2 weeks in myocardium. Cell-based therapy of ischemic heart or failing heart looks promising, but biodistribution and differentiation of transplanted cells are not known. Reporter genes can be transfected to the stem/progenitor cells and cells containing these genes can be transplanted to the recipients using catheter-based purging or injection. Repeated imaging should be available and if promoter are varied to let express reporter transgenes, cellular (trans)differentiation can be studied. NIS (sodium iodide symporter) or D2R receptor genes are promising in this aspect

  14. Evaluation of Patient Radiation Dose during Cardiac Interventional Procedures: What Is the Most Effective Method?

    International Nuclear Information System (INIS)

    Chida, K.; Saito, H.; Ishibashi, T.; Zuguchi, M.; Kagaya, Y.; Takahashi, S.

    2009-01-01

    Cardiac interventional radiology has lower risks than surgical procedures. This is despite the fact that radiation doses from cardiac intervention procedures are the highest of any commonly performed general X-ray examination. Maximum radiation skin doses (MSDs) should be determined to avoid radiation-associated skin injuries in patients undergoing cardiac intervention procedures. However, real-time evaluation of MSD is unavailable for many cardiac intervention procedures. This review describes methods of determining MSD during cardiac intervention procedures. Currently, in most cardiac intervention procedures, real-time measuring of MSD is not feasible. Thus, we recommend that physicians record the patient's total entrance skin dose, such as the dose at the interventional reference point when it can be monitored, in order to estimate MSD in intervention procedures

  15. Initial Efficacy of a Cardiac Rehabilitation Transition Program: Cardiac TRUST

    Science.gov (United States)

    Zullo, Melissa; Boxer, Rebecca; Moore, Shirley M.

    2012-01-01

    Patients recovering from cardiac events are increasingly using postacute care, such as home health care and skilled nursing facility services. The purpose of this pilot study was to test the initial efficacy, feasibility, and safety of a specially designed postacute care transitional rehabilitation intervention for cardiac patients. Cardiac Transitional Rehabilitation Using Self- Management Techniques (Cardiac TRUST) is a family-focused intervention that includes progressive low-intensity walking and education in self-management skills to facilitate recovery following a cardiac event. Using a randomized two-group design, exercise self-efficacy, steps walked, and participation in an outpatient cardiac rehabilitation program were compared in a sample of 38 older adults; 17 who received the Cardiac TRUST program and 21 who received usual care only. At discharge from postacute care, the intervention group had a trend for higher levels of self-efficacy for exercise outcomes (X=39.1, SD=7.4) than the usual care group (X=34.5; SD=7.0) (t-test 1.9, p=.06). During the 6 weeks following discharge, compared with the usual care group, the intervention group had more attendance in out-patient cardiac rehabilitation (33% compared to 11.8%, F=7.1, p=.03) and a trend toward more steps walked during the first week (X=1,307, SD=652 compared to X=782, SD=544, t-test 1.8, p=.07). The feasibility of the intervention was better for the home health participants than for those in the skilled nursing facility and there were no safety concerns. The provision of cardiac-focused rehabilitation during postacute care has the potential to bridge the gap in transitional services from hospitalization to outpatient cardiac rehabilitation for these patients at high risk for future cardiac events. Further evidence of the efficacy of Cardiac TRUST is warranted. PMID:22084960

  16. Output formatting in Apple-Soft Basic

    International Nuclear Information System (INIS)

    Navale, A.S.

    1987-01-01

    Personal computers are being used extensively in various fields. BASIC is a very popular and widely used language in personal computers. Apple computer is one of the popular machines used for scientific and engineering applications. Presenting output from computers in a neat and easy to read form is very important. Languages like FORTRAN have utility command 'FORMAT' which takes care of the formatting of the output in user-defined form. In some versions of BASIC a PRINT USING facility is available but it is not as powerful as the FORTRAN statement 'FORMAT'. Applesoft basic does not have even this PRINT USING command. Programmers have to write their own program segments to handle output formatting in Applesoft BASIC. Generally, such user written programs are of limited use as they cannot be used easily with other programs. A general purpose and easily transportable subroutine in Applesoft BASIC is presented here for handling output formatting in user-defined structure. The subroutine is nearly as powerful as the FORMAT statement in FORTRAN. It can also be used in other versions of BASIC with very little modifications. 3 tables, 4 refs. (author)

  17. On output regulation for linear systems

    NARCIS (Netherlands)

    Saberi, Ali; Stoorvogel, Antonie Arij; Sannuti, Peddapullaiah

    For both continuous- and discrete-time systems, we revisit the output regulation problem for linear systems. We generalize the problem formulation in order • to expand the class of reference or disturbance signals, • to utilize the derivative or feedforward information of reference signals whenever

  18. Fast Output-sensitive Matrix Multiplication

    DEFF Research Database (Denmark)

    Jacob, Riko; Stöckel, Morten

    2015-01-01

    We consider the problem of multiplying two $U \\times U$ matrices $A$ and $C$ of elements from a field $\\F$. We present a new randomized algorithm that can use the known fast square matrix multiplication algorithms to perform fewer arithmetic operations than the current state of the art for output...

  19. Predicting Color Output of Additive Manufactured Parts

    DEFF Research Database (Denmark)

    Eiríksson, Eyþór Rúnar; Pedersen, David Bue; Aanæs, Henrik

    2015-01-01

    In this paper we address the colorimetric performance of a multicolor additive manufacturing process. A method on how to measure and characterize color performance of said process is presented. Furthermore, a method on predicting the color output is demonstrated, allowing for previsualization...

  20. Multiple output timing and trigger generator

    Energy Technology Data Exchange (ETDEWEB)

    Wheat, Robert M. [Los Alamos National Laboratory; Dale, Gregory E [Los Alamos National Laboratory

    2009-01-01

    In support of the development of a multiple stage pulse modulator at the Los Alamos National Laboratory, we have developed a first generation, multiple output timing and trigger generator. Exploiting Commercial Off The Shelf (COTS) Micro Controller Units (MCU's), the timing and trigger generator provides 32 independent outputs with a timing resolution of about 500 ns. The timing and trigger generator system is comprised of two MCU boards and a single PC. One of the MCU boards performs the functions of the timing and signal generation (the timing controller) while the second MCU board accepts commands from the PC and provides the timing instructions to the timing controller. The PC provides the user interface for adjusting the on and off timing for each of the output signals. This system provides 32 output or timing signals which can be pre-programmed to be in an on or off state for each of 64 time steps. The width or duration of each of the 64 time steps is programmable from 2 {micro}s to 2.5 ms with a minimum time resolution of 500 ns. The repetition rate of the programmed pulse train is only limited by the time duration of the programmed event. This paper describes the design and function of the timing and trigger generator system and software including test results and measurements.

  1. What shapes output of policy reform?

    DEFF Research Database (Denmark)

    Carlsen, Kirsten

    This thesis deals with the factors shaping forest policy output during the stages implementation and bases its main message on empirical findings from the forestry sector in Ghana. Policy and institutional factors are important underlying causes for deforestation, especially in the tropics. Fores...

  2. Monetary policy and regional output in Brazil

    Directory of Open Access Journals (Sweden)

    Rafael Rockenbach da Silva Guimarães

    2014-03-01

    Full Text Available This work presents an analysis of whether the effects of the Brazilian monetary policy on regional outputs are symmetric. The strategy developed combines the techniques of principal component analysis (PCA to decompose the variables that measure regional economic activity into common and region-specific components and vector autoregressions (VAR to observe the behavior of these variables in response to monetary policy shocks. The common component responds to monetary policy as expected. Additionally, the idiosyncratic components of the regions showed no impact of monetary policy. The main finding of this paper is that the monetary policy responses on regional output are symmetrical when the regional output decomposition is performed, and the responses are asymmetrical when this decomposition is not performed. Therefore, performing the regional output decomposition corroborates the economic intuition that monetary policy has no impact on region-specific issues. Once monetary policy affects the common component of the regional economic activity and does not impact its idiosyncratic components, it can be considered symmetrical.

  3. Association of morning blood pressure surge with carotid intima-media thickness and cardiac dysfunction in patients with cardiac syndrome-X.

    Science.gov (United States)

    Mahfouz, Ragab A; Goda, Mohammad; Galal, Islam; Ghareb, Mohamed S

    2018-05-23

    Background & hypothesis: We hypothesized that exaggerated morning blood pressure surge, may contribute in cardiac dysfunction and arterial stiffness in patients with cardiac syndrome X. Thus we investigated the impact of morning blood pressure surge on cardiac function and carotid intima-media thickness in subjects with cardiac syndrome X. We studied patients with cardiac syndrome X using ambulatory blood pressure monitoring and investigated the association of morning blood pressure surge with carotid intima thickness, left atrial volume index and left ventricular filling (E/e'). Seventy patients with cardiac syndrome X were enrolled for the study and compared with 70 age and sex matched controls. Patients with cardiac syndrome X were stratified based on the systolic morning blood pressure surge value of control subjects to patients with exaggerated blood pressure surge (n = 42) and those with normal morning blood pressure surge (n = 28). Basal heart rate (p blood pressure surge group than those with morning blood pressure surge group. Morning blood pressure surge was significantly correlated with carotid intima-media thickness, high sensitive C-reactive protein, left atrial volume index and E/e' ratio in patients with cardiac syndrome X. In multivariate analysis, exaggerated morning blood pressure surge was the only independent predictor of increased carotid intima-media thickness (OR = 2.379; p blood pressure surge is an independent predictor for arterial stiffness and diastolic dysfunction in patients with cardiac syndrome X.

  4. Topical minoxidil: cardiac effects in bald man.

    Science.gov (United States)

    Leenen, F H; Smith, D L; Unger, W P

    1988-01-01

    Systemic cardiovascular effects during chronic treatment with topical minoxidil vs placebo were evaluated using a double-blind, randomized design for two parallel groups (n = 20 for minoxidil, n = 15 for placebo). During 6 months of follow-up, blood pressure did not change, whereas minoxidil increased heart rate by 3-5 beats min-1. Compared with placebo, topical minoxidil caused significant increases in LV end-diastolic volume, in cardiac output (by 0.751 min-1) and in LV mass (by 5 g m-2). We conclude that in healthy subjects short-term use of topical minoxidil is likely not to be detrimental. However, safety needs to be established regarding ischaemic symptoms in patients with coronary artery disease as well as for the possible development of LV hypertrophy in healthy subjects during years of therapy. PMID:3191000

  5. Artificial Neural Networks to Predict the Power Output of a PV Panel

    Directory of Open Access Journals (Sweden)

    Valerio Lo Brano

    2014-01-01

    Full Text Available The paper illustrates an adaptive approach based on different topologies of artificial neural networks (ANNs for the power energy output forecasting of photovoltaic (PV modules. The analysis of the PV module’s power output needed detailed local climate data, which was collected by a dedicated weather monitoring system. The Department of Energy, Information Engineering, and Mathematical Models of the University of Palermo (Italy has built up a weather monitoring system that worked together with a data acquisition system. The power output forecast is obtained using three different types of ANNs: a one hidden layer Multilayer perceptron (MLP, a recursive neural network (RNN, and a gamma memory (GM trained with the back propagation. In order to investigate the influence of climate variability on the electricity production, the ANNs were trained using weather data (air temperature, solar irradiance, and wind speed along with historical power output data available for the two test modules. The model validation was performed by comparing model predictions with power output data that were not used for the network's training. The results obtained bear out the suitability of the adopted methodology for the short-term power output forecasting problem and identified the best topology.

  6. Sacral Neuromodulation in Patients With a Cardiac Pacemaker

    Directory of Open Access Journals (Sweden)

    Abdullah A. Gahzi

    2016-09-01

    Full Text Available The objective of this study was to describe our experience using sacral neuromodulation to treat urinary urgency, frequency, urge incontinence, and chronic urinary retention in patients with cardiac pacemakers. With the increasingly widespread use of InterStim for bladder function restoration, we are seeing more complex patients with multiple comorbidities, including cardiac conditions. Herein, we report 3 cases of individuals with cardiac pacemakers who underwent InterStim implantation to treat urinary conditions. This study is a case series of 3 patients with cardiac pacemakers who underwent sacral neuromodulation to treat refractory voiding dysfunction. The initial patient screening for InterStim therapy involved percutaneous nerve evaluation (PNE, in which a temporary untined lead wire was placed through the S3 foramen. Patients who did not respond to PNE proceeded to a staged implant. All patients in this study had a greater than 50% improvement of their urinary symptoms during the initial trial and underwent placement of the InterStim implantable pulse generator (IPG. Postoperative programming was done under electrocardiogram monitoring by a cardiologist. No interference was observed between the Inter-Stim IPG and the cardiac pacemaker. In this group of patients, sacral neuromodulation in the presence of a cardiac pacemaker appears to have been safe.

  7. Cardiac arrest due to lymphocytic colitis: a case report

    Directory of Open Access Journals (Sweden)

    Groth Kristian A

    2012-03-01

    Full Text Available Abstract Introduction We present a case of cardiac arrest due to hypokalemia caused by lymphocytic colitis. Case presentation A 69-year-old Caucasian man presented four months prior to a cardiac arrest with watery diarrhea and was diagnosed with lymphocytic colitis. Our patient experienced a witnessed cardiac arrest at his general practitioner's surgery. Two physicians and the emergency medical services resuscitated our patient for one hour and four minutes before arriving at our university hospital. Our patient was defibrillated 16 times due to the recurrence of ventricular tachyarrhythmias. An arterial blood sample revealed a potassium level of 2.0 mmol/L (reference range: 3.5 to 4.6 mmol/L and pH 6.86 (reference range: pH 7.37 to 7.45. As the potassium level was corrected, the propensity for ventricular tachyarrhythmias ceased. Our patient recovered from his cardiac arrest without any neurological deficit. Further tests and examinations revealed no other reason for the cardiac arrest. Conclusion Diarrhea can cause life-threatening situations due to the excretion of potassium, ultimately causing cardiac arrest due to hypokalemia. Physicians treating patients with severe diarrhea should consider monitoring their electrolyte levels.

  8. Is it time for cardiac innervation imaging?

    Energy Technology Data Exchange (ETDEWEB)

    Knuuti, J. [Turku Univ., Turku (Finland) Turku PET Center; Sipola, P. [Kuopio Univ., Kuopio (Finland)

    2005-03-01

    The autonomic nervous system plays an important role in the regulation of cardiac function and the regional distribution of cardiac nerve terminals can be visualized using scintigraphic techniques. The most commonly used tracer is iodine-123-metaiodobenzylguanidine (MIBG) but C-11-hydroxyephedrine has also been used with PET. When imaging with MIBG, the ratio of heart-to-mediastinal counts is used as an index of tracer uptake, and regional distribution is also assessed from tomographic images. The rate of clearance of the tracer can also be measured and indicates the function of the adrenergic system. Innervation imaging has been applied in patients with susceptibility to arrythmias, coronary artery disease, hypertrophic and dilated cardiomyopathy and anthracycline induced cardiotoxicity. Abnormal adrenergic innervation or function appear to exist in many pathophysiological conditions indicating that sympathetic neurons are very susceptible to damage. Abnormal findings in innervation imaging also appear to have significant prognostic value especially in patients with cardiomyopathy. Recently, it has also been shown that innervation imaging can monitor drug-induced changes in cardiac adrenergic activity. Although innervation imaging holds great promise for clinical use, the method has not received wider clinical acceptance. Larger randomized studies are required to confirm the value of innervation imaging in various specific indications.

  9. Cardiac risk assessment before carotid endarterectomy

    International Nuclear Information System (INIS)

    Rabee, Hussein M.M.

    2000-01-01

    Preoperative cardiac assessment is an essential step to identify the patients at risk, optimize any dysfunction, anticipate perioperative and postoperative problems and plan special management. Carotid endarterectomy (CEA) has become one of the most commonly performed vascular procedures in Western countries. The awareness of the potential beneficial role and hazards of CEA is not proportionate to the magnitude of this problem in our countries, not only among patients, but also among the medical disciplines. This report is a retrospective analysis of the prevalence of coronary artery diseases among 442 patients who were referred to the Division of Vascular Surgery at the King Khalid University Hospital in Riyadh, Saudi Arabia with suspicion of carotid artery disease. Eighty-two patients proved to have significant carotid artery stenosis and had thorough preoperative cardiac assessment by senior cardiologist. All cases had clinical assessment and ECG, 66 cases had echocardiogram examination, 44 had Dipyridamole Thallium-scan and 12 had coronary angiogram. Sixty-eight patients underwent 76 carotid endarterectomy. Four of them had MI and only one case died during preoperative period. This study shows that cardiac screening studies have a potential role in the candidates for carotid surgery in influencing the decision to operate and intensify of perioperative monitoring and care. We believe that the teamwork should involve vascular surgeons, cardiologist and anesthetist to manage such critical patients properly. (author)

  10. Beam profile monitor

    International Nuclear Information System (INIS)

    Krausse, G.J.; Gram, P.A.M.

    1978-05-01

    A system used to monitor secondary beam profiles at the LAMPF Linac for channel tune-up and diagnostics is described. The multiwire proportional chamber design is discussed, and descriptions and drawings of the gate card, the amplifier/multiplexer card, the output amplifier card, and the overall system are given

  11. Real-time MRI guidance of cardiac interventions.

    Science.gov (United States)

    Campbell-Washburn, Adrienne E; Tavallaei, Mohammad A; Pop, Mihaela; Grant, Elena K; Chubb, Henry; Rhode, Kawal; Wright, Graham A

    2017-10-01

    Cardiac magnetic resonance imaging (MRI) is appealing to guide complex cardiac procedures because it is ionizing radiation-free and offers flexible soft-tissue contrast. Interventional cardiac MR promises to improve existing procedures and enable new ones for complex arrhythmias, as well as congenital and structural heart disease. Guiding invasive procedures demands faster image acquisition, reconstruction and analysis, as well as intuitive intraprocedural display of imaging data. Standard cardiac MR techniques such as 3D anatomical imaging, cardiac function and flow, parameter mapping, and late-gadolinium enhancement can be used to gather valuable clinical data at various procedural stages. Rapid intraprocedural image analysis can extract and highlight critical information about interventional targets and outcomes. In some cases, real-time interactive imaging is used to provide a continuous stream of images displayed to interventionalists for dynamic device navigation. Alternatively, devices are navigated relative to a roadmap of major cardiac structures generated through fast segmentation and registration. Interventional devices can be visualized and tracked throughout a procedure with specialized imaging methods. In a clinical setting, advanced imaging must be integrated with other clinical tools and patient data. In order to perform these complex procedures, interventional cardiac MR relies on customized equipment, such as interactive imaging environments, in-room image display, audio communication, hemodynamic monitoring and recording systems, and electroanatomical mapping and ablation systems. Operating in this sophisticated environment requires coordination and planning. This review provides an overview of the imaging technology used in MRI-guided cardiac interventions. Specifically, this review outlines clinical targets, standard image acquisition and analysis tools, and the integration of these tools into clinical workflow. 1 Technical Efficacy: Stage 5 J

  12. Use of the cardiopulmonary flow index to evaluate cardiac function in thoroughbred horses

    International Nuclear Information System (INIS)

    Guthrie, A.J.; Killeen, V.M.; Grosskopf, J.F.W.

    1991-01-01

    The ratio of the cardiopulmonary blood volume to stroke volume is called the cardiopulmonary flow index (CPFI). The CPFI can be determined indirectly from the simultaneous recording of a radiocardiogram and an electrocardiogram. The CPFI and cardiac output were measured simultaneously in horses that were diagnosed as having cardiac disease. The results obtained from these subjects were compared with those from control animals and significant differences were found between the mean CPFI of the control horses and those with macroscopically visible myocardial fibrosis on post mortem examination. No significant differences were found between the means of the cardiac output measured in either of the groups of horses. The effect of pharmacological acceleration of the heart rate on the CPFI was also studied. Significant differences were found between the mean CPFI and the slopes of the regression lines of CPFI on heart rate of the control and principal groups of horses. These differences were greatest at heart rates near to the resting heart rates of the individuals. The CPFI was found to be a more sensitive measure of cardiac function than cardiac output, in the horses. 16 refs., 2 figs., 2 tabs

  13. Spatiotemporal representation of cardiac vectorcardiogram (VCG signals

    Directory of Open Access Journals (Sweden)

    Yang Hui

    2012-03-01

    Full Text Available Abstract Background Vectorcardiogram (VCG signals monitor both spatial and temporal cardiac electrical activities along three orthogonal planes of the body. However, the absence of spatiotemporal resolution in conventional VCG representations is a major impediment for medical interpretation and clinical usage of VCG. This is especially so because time-domain features of 12-lead ECG, instead of both spatial and temporal characteristics of VCG, are widely used for the automatic assessment of cardiac pathological patterns. Materials and methods We present a novel representation approach that captures critical spatiotemporal heart dynamics by displaying the real time motion of VCG cardiac vectors in a 3D space. Such a dynamic display can also be realized with only one lead ECG signal (e.g., ambulatory ECG through an alternative lag-reconstructed ECG representation from nonlinear dynamics principles. Furthermore, the trajectories are color coded with additional dynamical properties of space-time VCG signals, e.g., the curvature, speed, octant and phase angles to enhance the information visibility. Results In this investigation, spatiotemporal VCG signal representation is used to characterize various spatiotemporal pathological patterns for healthy control (HC, myocardial infarction (MI, atrial fibrillation (AF and bundle branch block (BBB. The proposed color coding scheme revealed that the spatial locations of the peak of T waves are in the Octant 6 for the majority (i.e., 74 out of 80 of healthy recordings in the PhysioNet PTB database. In contrast, the peak of T waves from 31.79% (117/368 of MI subjects are found to remain in Octant 6 and the rest (68.21% spread over all other octants. The spatiotemporal VCG signal representation is shown to capture the same important heart characteristics as the 12-lead ECG plots and more. Conclusions Spatiotemporal VCG signal representation is shown to facilitate the characterization of space-time cardiac

  14. From sensor output to improved product quality

    NARCIS (Netherlands)

    Hertog, M.L.A.T.M.; Vollebregt, Martijntje; Unzueta, I.; Hoofman, R.J.O.M.; Lammertyn, J.

    2015-01-01

    The research conducted in the European PASTEUR project focussed on perishables monitoring through smart tracking of lifetime and quality. The aim was to develop a wireless sensor platform to monitor the environmental conditions of perishable goods in the supply chain between producer and

  15. Regimes of data output from an automated scanning system into a computer

    International Nuclear Information System (INIS)

    Ovsov, Yu.V.; Shaislamov, P.T.

    1984-01-01

    A method is described for accomplishment of rather a complex algorithm of various coordinate and service data transmission from different automated scanning system devices into a monitoring computer in the automated system for processing images from bubble chambers. The accepted data output algorithm and the developed appropriate equipment enable data transmission both in separate words and word arrays

  16. Monitor inspection device

    International Nuclear Information System (INIS)

    Ueshima, Yoshinobu.

    1995-01-01

    The device of the present invention reliably conducts monitoring by radiation monitors in a nuclear power plant thereby contributing to save the number of radiation operators and reduction of radiation exposure. Namely, radiation monitors continuously measure a plurality of γ-ray levels. A branched simultaneously counting circuit receives these signals. The output of the branched simultaneously counting circuit is inputted to a differentiation means. The differentiation means calculates a variation coefficient for each of the radiation monitoring values, namely, equivalent dose rates, and records and monitors change with time of the equivalent dose rates. With such procedures, the results of the monitoring of γ-ray levels can be judged objectively corresponding to the increase of the equivalent dose rates. As a result, the number of radiation operators can be saves and radiation exposure of the radiation operators can be reduced. (I.S.)

  17. Antifibrinolytics in cardiac surgery

    Directory of Open Access Journals (Sweden)

    Achal Dhir

    2013-01-01

    Full Text Available Cardiac surgery exerts a significant strain on the blood bank services and is a model example in which a multi-modal blood-conservation strategy is recommended. Significant bleeding during cardiac surgery, enough to cause re-exploration and/or blood transfusion, increases morbidity and mortality. Hyper-fibrinolysis is one of the important contributors to increased bleeding. This knowledge has led to the use of anti-fibrinolytic agents especially in procedures performed under cardiopulmonary bypass. Nothing has been more controversial in recent times than the aprotinin controversy. Since the withdrawal of aprotinin from the world market, the choice of antifibrinolytic agents has been limited to lysine analogues either tranexamic acid (TA or epsilon amino caproic acid (EACA. While proponents of aprotinin still argue against its non-availability. Health Canada has approved its use, albeit under very strict regulations. Antifibrinolytic agents are not without side effects and act like double-edged swords, the stronger the anti-fibrinolytic activity, the more serious the side effects. Aprotinin is the strongest in reducing blood loss, blood transfusion, and possibly, return to the operating room after cardiac surgery. EACA is the least effective, while TA is somewhere in between. Additionally, aprotinin has been implicated in increased mortality and maximum side effects. TA has been shown to increase seizure activity, whereas, EACA seems to have the least side effects. Apparently, these agents do not differentiate between pathological and physiological fibrinolysis and prevent all forms of fibrinolysis leading to possible thrombotic side effects. It would seem prudent to select the right agent knowing its risk-benefit profile for a given patient, under the given circumstances.

  18. [Structure and functional organization of integrated cardiac intensive care].

    Science.gov (United States)

    Scherillo, Marino; Miceli, Domenico; Tubaro, Marco; Guiducci, Umberto

    2007-05-01

    The early invasive strategy for the treatment of acute coronary syndromes and the increasing number of older and sicker patients requiring prolonged and more complex intensive care have induced many changes in the function of the intensive care units. These changes include the statement that specially trained cardiologists and cardiac nurses who can manage patients with acute cardiac conditions should staff the intensive care units. This document indicates the structure of the units and specific recommendations for the number of beds, monitoring system, respirators, pacemaker/defibrillators and additional equipment.

  19. Usefulness of emergency ultrasound in nontraumatic cardiac arrest.

    Science.gov (United States)

    Volpicelli, Giovanni

    2011-02-01

    Treatment of nontraumatic cardiac arrest in the hospital setting depends on the recognition of heart rhythm and differential diagnosis of the underlying condition while maintaining a constant oxygenated blood flow by ventilation and chest compression. Diagnostic process relies only on patient's history, physical findings, and active electrocardiography. Ultrasound is not currently scheduled in the resuscitation guidelines. Nevertheless, the use of real-time ultrasonography during resuscitation has the potential to improve diagnostic accuracy and allows the physician a greater confidence in deciding aggressive life-saving therapeutic procedures. This article reviews the current opinions and literature about the use of emergency ultrasound during resuscitation of nontraumatic cardiac arrest. Cardiac and lung ultrasound have a great potential in identifying the reversible mechanical causes of pulseless electrical activity or asystole. Brief examination of the heart can even detect a real cardiac standstill regardless of electrical activity displayed on the monitor, which is a crucial prognostic indicator. Moreover, ultrasound can be useful to verify and monitor the tracheal tube placement. Limitation to the use of ultrasound is the need to minimize the no-flow intervals during mechanical cardiopulmonary resuscitation. However, real-time ultrasound can be successfully applied during brief pausing of chest compression and first pulse-check. Finally, lung sonographic examination targeted to the detection of signs of pulmonary congestion has the potential to allow hemodynamic noninvasive monitoring before and after mechanical cardiopulmonary maneuvers. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. Exercise-related cardiac arrest in cardiac rehabilitation - The ...

    African Journals Online (AJOL)

    Prescribed physical activity plays a major role in the rehabilitation of patients with coronary artery disease, and as with any other form of treatment its benefits must be weighed against its possible risks. This study attempted to establish the safety of cardiac rehabilitation as a medical intervention at the Johannesburg Cardiac ...