WorldWideScience

Sample records for cardiac mri works

  1. Cardiac MRI of the athlete's heart

    NARCIS (Netherlands)

    Prakken, N.H.J.

    2010-01-01

    The increase in pre-participation cardiovascular screening using the Lausanne protocol will ultimately lead to an increased use of cardiac MRI and MDCT in the cardiovascular work-up of athletes. The role of cardiac MRI is well established in the evaluation of cardiomyopathies, myocarditis, aortic

  2. Measuring cardiac efficiency using PET/MRI

    International Nuclear Information System (INIS)

    Gullberg, Grand; Aparici, Carina Mari; Brooks, Gabriel; Liu, Jing; Guccione, Julius; Saloner, David; Seo, Adam Youngho; Ordovas, Karen Gomes

    2015-01-01

    Heart failure (HF) is a complex syndrome that is projected by the American Heart Association to cost $160 billion by 2030. In HF, significant metabolic changes and structural remodeling lead to reduced cardiac efficiency. A normal heart is approximately 20-25% efficient measured by the ratio of work to oxygen utilization (1 ml oxygen = 21 joules). The heart requires rapid production of ATP where there is complete turnover of ATP every 10 seconds with 90% of ATP produced by mitochondrial oxidative metabolism requiring substrates of approximately 30% glucose and 65% fatty acids. In our preclinical PET/MRI studies in normal rats, we showed a negative correlation between work and the influx rate constant for 18FDG, confirming that glucose is not the preferred substrate at rest. However, even though fatty acid provides 9 kcal/gram compared to 4 kcal/gram for glucose, in HF the preferred energy source is glucose. PET/MRI offers the potential to study this maladapted mechanism of metabolism by measuring work in a region of myocardial tissue simultaneously with the measure of oxygen utilization, glucose, and fatty acid metabolism and to study cardiac efficiency in the etiology of and therapies for HF. MRI is used to measure strain and a finite element mechanical model using pressure measurements is used to estimate myofiber stress. The integral of strain times stress provides a measure of work which divided by energy utilization, estimated by the production of 11CO2 from intravenous injection of 11C-acetate, provides a measure of cardiac efficiency. Our project involves translating our preclinical research to the clinical application of measuring cardiac efficiency in patients. Using PET/MRI to develop technologies for studying myocardial efficiency in patients, provides an opportunity to relate cardiac work of specific tissue regions to metabolic substrates, and measure the heterogeneity of LV efficiency.

  3. Measuring cardiac efficiency using PET/MRI

    Energy Technology Data Exchange (ETDEWEB)

    Gullberg, Grand [Lawrence Berkeley National Laboratory (United States); Aparici, Carina Mari; Brooks, Gabriel [University of California San Francisco (United States); Liu, Jing; Guccione, Julius; Saloner, David; Seo, Adam Youngho; Ordovas, Karen Gomes [Lawrence Berkeley National Laboratory (United States)

    2015-05-18

    Heart failure (HF) is a complex syndrome that is projected by the American Heart Association to cost $160 billion by 2030. In HF, significant metabolic changes and structural remodeling lead to reduced cardiac efficiency. A normal heart is approximately 20-25% efficient measured by the ratio of work to oxygen utilization (1 ml oxygen = 21 joules). The heart requires rapid production of ATP where there is complete turnover of ATP every 10 seconds with 90% of ATP produced by mitochondrial oxidative metabolism requiring substrates of approximately 30% glucose and 65% fatty acids. In our preclinical PET/MRI studies in normal rats, we showed a negative correlation between work and the influx rate constant for 18FDG, confirming that glucose is not the preferred substrate at rest. However, even though fatty acid provides 9 kcal/gram compared to 4 kcal/gram for glucose, in HF the preferred energy source is glucose. PET/MRI offers the potential to study this maladapted mechanism of metabolism by measuring work in a region of myocardial tissue simultaneously with the measure of oxygen utilization, glucose, and fatty acid metabolism and to study cardiac efficiency in the etiology of and therapies for HF. MRI is used to measure strain and a finite element mechanical model using pressure measurements is used to estimate myofiber stress. The integral of strain times stress provides a measure of work which divided by energy utilization, estimated by the production of 11CO2 from intravenous injection of 11C-acetate, provides a measure of cardiac efficiency. Our project involves translating our preclinical research to the clinical application of measuring cardiac efficiency in patients. Using PET/MRI to develop technologies for studying myocardial efficiency in patients, provides an opportunity to relate cardiac work of specific tissue regions to metabolic substrates, and measure the heterogeneity of LV efficiency.

  4. Cardiac MRI in ischemic heart disease

    International Nuclear Information System (INIS)

    Ishida, Masaki; Kato, Shingo; Sakuma, Hajime

    2009-01-01

    Considerable progress has been made in cardiac magnetic resonance imaging (MRI). Cine MRI is recognized as the most accurate method for evaluating ventricular function. Late gadolinium-enhanced MRI can clearly delineate subendocardial infarction, and the assessment of transmural extent of infarction on MRI is widely useful for predicting myocardial viability. Stress myocardial perfusion MRI allows for detection of subendocardial myocardial ischemia, and the diagnostic accuracy of stress perfusion MRI is superior to stress perfusion single-photon emission computed tomography in patients with multivessel coronary artery disease (CAD). In recent years, image quality, volume coverage, acquisition speed and arterial contrast of 3-dimensional coronary magnetic resonance angiography (MRA) have been substantially improved with use of steady-state free precession sequences and parallel imaging techniques, permitting the acquisition of high-quality, whole-heart coronary MRA within a reasonably short imaging time. It is now widely recognized that cardiac MRI has tremendous potential for the evaluation of ischemic heart disease. However, cardiac MRI is technically complicated and its use in clinical practice is relatively limited. With further improvements in education and training, as well as standardization of appropriate study protocols, cardiac MRI will play a central role in managing patients with CAD. (author)

  5. Practical textbook of cardiac CT and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Tae-Hwan (ed.) [ASAN Medical Center, Seoul (Korea, Republic of). Dept. of Radiology

    2015-04-01

    Guide to the interpretation of cardiac CT and MRI for the purposes of diagnosis, treatment planning, and follow-up. Emphasis on applications in a wide range of real clinical situations. Numerous informative illustrations. Summarizing sections permitting rapid retrieval of information. QR codes allowing access to references, additional figures, and motion pictures from the internet. This up-to-date textbook comprehensively reviews all aspects of cardiac CT and MRI and demonstrates the value of these techniques in clinical practice. A wide range of applications are considered, including imaging of atherosclerotic and non-atherosclerotic coronary artery disease, coronary revascularization, ischemic heart disease, non-ischemic cardiomyopathy, valvular heart disease, cardiac tumors, and pericardial disease. The numerous high-quality images illustrate how to interpret cardiac CT and MRI correctly for the purposes of diagnosis, treatment planning, and follow-up. Helpful summarizing sections in every chapter will facilitate rapid retrieval of information. This book will be of great value to radiologists and cardiologists seeking a reliable guide to the optimal use of cardiac CT and MRI in real clinical situations.

  6. Practical textbook of cardiac CT and MRI

    International Nuclear Information System (INIS)

    Lim, Tae-Hwan

    2015-01-01

    Guide to the interpretation of cardiac CT and MRI for the purposes of diagnosis, treatment planning, and follow-up. Emphasis on applications in a wide range of real clinical situations. Numerous informative illustrations. Summarizing sections permitting rapid retrieval of information. QR codes allowing access to references, additional figures, and motion pictures from the internet. This up-to-date textbook comprehensively reviews all aspects of cardiac CT and MRI and demonstrates the value of these techniques in clinical practice. A wide range of applications are considered, including imaging of atherosclerotic and non-atherosclerotic coronary artery disease, coronary revascularization, ischemic heart disease, non-ischemic cardiomyopathy, valvular heart disease, cardiac tumors, and pericardial disease. The numerous high-quality images illustrate how to interpret cardiac CT and MRI correctly for the purposes of diagnosis, treatment planning, and follow-up. Helpful summarizing sections in every chapter will facilitate rapid retrieval of information. This book will be of great value to radiologists and cardiologists seeking a reliable guide to the optimal use of cardiac CT and MRI in real clinical situations.

  7. Establishing a clinical cardiac MRI service

    International Nuclear Information System (INIS)

    O'Regan, D.P.; Schmitz, S.A.

    2006-01-01

    After several years of research development cardiovascular MRI has evolved into a widely accepted clinical tool. It offers important diagnostic and prognostic information for a variety of clinical indications, which include ischaemic heart disease, cardiomyopathies, valvular dysfunction and congenital heart disorders. It is a safe non-invasive technique that employs a variety of imaging sequences optimized for temporal or spatial resolution, tissue-specific contrast, flow quantification or angiography. Cardiac MRI offers specific advantages over conventional imaging techniques for a significant number of patients. The demand for cardiac MRI studies from cardiothoracic surgeons, cardiologists and other referrers is likely to continue to rise with pressure for more widespread local service provision. Setting up a cardiac MRI service requires careful consideration regarding funding issues and how it will be integrated with existing service provision. The purchase of cardiac phased array coils, monitoring equipment and software upgrades must also be considered, as well as the training needs of those involved. The choice of appropriate imaging protocols will be guided by operator experience, clinical indication and equipment capability, and is likely to evolve as the service develops. Post-processing and offline analysis form a significant part of the time taken to report studies and an efficient method of providing quantitative reports is an important requirement. Collaboration between radiologists and cardiologists is needed to develop a successful service and multi-disciplinary meetings are key component of this. This review will explore these issues from our perspective of a new clinical cardiac MRI service operating over its first year in a teaching hospital imaging department

  8. Performance evaluation of cardiac MRI image denoising techniques

    NARCIS (Netherlands)

    AlAttar, M.A.; Mohamed, A.G.A.; Osman, N.F.; Fahmy, A.S.

    2008-01-01

    Black-blood cardiac magnetic resonance imaging (MRI) plays an important role in diagnosing a number of heart diseases. The technique suffers inherently from low contrast-to-noise ratio between the myocardium and the blood. In this work, we examined the performance of different classification

  9. Cardiac MRI in patients with complex CHD following primary or secondary implantation of MRI-conditional pacemaker system.

    Science.gov (United States)

    Al-Wakeel, Nadya; O h-Ici, Darach; Schmitt, Katharina R; Messroghli, Daniel R; Riesenkampff, Eugénie; Berger, Felix; Kuehne, Titus; Peters, Bjoern

    2016-02-01

    In patients with CHD, cardiac MRI is often indicated for functional and anatomical assessment. With the recent introduction of MRI-conditional pacemaker systems, cardiac MRI has become accessible for patients with pacemakers. The present clinical study aims to evaluate safety, susceptibility artefacts, and image reading of cardiac MRI in patients with CHD and MRI-conditional pacemaker systems. Material and methods CHD patients with MRI-conditional pacemaker systems and a clinical need for cardiac MRI were examined with a 1.5-T MRI system. Lead function was tested before and after MRI. Artefacts and image readings were evaluated using a four-point grading scale. A total of nine patients with CHD (mean age 34.0 years, range 19.5-53.6 years) received a total of 11 cardiac MRI examinations. Owing to clinical indications, seven patients had previously been converted from conventional to MRI-conditional pacemaker systems. All MRI examinations were completed without adverse effects. Device testing immediately after MRI and at follow-up showed no alteration of pacemaker device and lead function. Clinical questions could be addressed and answered in all patients. Cardiac MRI can be performed safely with high certainty of diagnosis in CHD patients with MRI-conditional pacemaker systems. In case of clinically indicated lead and box changing, CHD patients with non-MRI-conditional pacemaker systems should be considered for complete conversion to MRI-conditional systems.

  10. An MRI-Conditional External Cardiac Defibrillator for Resuscitation Within the MRI Scanner Bore

    Science.gov (United States)

    Schmidt, Ehud J.; Watkins, Ronald D.; Zviman, Menekhem M.; Guttman, Michael A.; Wang, Wei; Halperin, Henry A.

    2016-01-01

    Background Subjects undergoing cardiac arrest within an MRI scanner are currently removed from the bore and then from the MRI suite, prior to delivery of CPR and defibrillation, potentially increasing risk of mortality. This precludes many higher-risk (acute-ischemic, acute-stroke) patients from undergoing MRI imaging and MRI-guided intervention. An MRI-conditional cardiac defibrillator should enable scanning with defibrillation pads attached and the generator ON, enabling application of defibrillation within the MRI seconds after a cardiac event. An MRI-conditional external defibrillator may improve patient acceptance for MRI procedures. Methods and Results A commercial external defibrillator was rendered 1.5 Tesla MRI-conditional by addition of novel Radio-Frequency (RF) filters between the generator and commercial disposable surface-pads. The RF filters reduced emission into the MRI scanner, and prevented cable/surface-pad heating during imaging, while preserving all the defibrillator’s monitoring and delivery functions. Human volunteers were imaged using high Specific-Absorption-Rate sequences to validate MRI image quality (IQ) and lack of heating. Swine were electrically fibrillated (N=4) and thereafter defibrillated both outside and inside the MRI bore. MRI IQ was reduced by 0.8 or 1.6 dB, with the generator in monitoring mode and operating on battery or AC power, respectively. Commercial surface-pads did not create artifacts deeper than 6mm below the skin surface. RF heating was within FDA guidelines. Defibrillation was completely successful inside and outside the MRI bore. Conclusions A prototype MRI-conditional defibrillation system successfully defibrillated in the MRI without degrading image quality, or increasing the time needed for defibrillation. It can increase patient acceptance for MRI procedures. PMID:27729363

  11. Nuclear magnetic resonance in cardiology: cardiac MRI

    International Nuclear Information System (INIS)

    Fernandez, Claudio C.

    2003-01-01

    As a new gold standard for mass, volume and flow, the magnetic resonance imaging (MRI) is probably the most rapidly evolving technique in the cardiovascular diagnosis. An integrated cardiac MRI examination allows the evaluation of morphology, global and regional function, coronary anatomy, perfusion, viability and myocardial metabolism, all of them in only one diagnostic test and in a totally noninvasive manner. The surgeons can obtain relevant information on all aspects of diseases of the heart and great vessels, which include anatomical details and relationships with the greatest field of view, and may help to reduce the number of invasive procedures required in pre and postoperative evaluation. However, despite these excellent advantages the present clinical utilization of MRI is still too often restricted to few pathologies or case studies in which other techniques fail to identify the cardiac or cardiovascular abnormalities. If magnetic resonance is an excellent method for diagnosing so many different cardiac conditions, why is so little it used in routine cardiac practice? Cardiologists are still not very familiar with the huge possibilities or cardiovascular MRI utilities. Our intention is to give a comprehensive survey of many of the clinical applications of this challenger technique in the study of the heart and great vessels. Those who continue to ignore this important and mature imaging technique will rightly fail to benefit. (author) [es

  12. Delayed contrast-enhanced MRI: use in myocardial viability assessment and other cardiac pathology

    International Nuclear Information System (INIS)

    Bogaert, J.; Dymarkowski, S.

    2005-01-01

    As in other organs, tissue characterization is important for many cardiac diseases. For example, in ischemic heart disease, differentiation between reversibly and irreversibly damaged myocardium in patients with a prior myocardial infarction is crucial in determining disease severity, functional recovery and patient outcome. With the recent advent of the single inversion-recovery contrast-enhanced magnetic resonance imaging (MRI) sequence (delayed contrast-enhanced MRI), contrast between normal and abnormal tissues could be significantly enhanced compared with the conventional cardiac MRI sequences, enabling even subtle abnormalities to be visualized. Together with other advances in cardiac MRI (e.g. functional imaging, coronary artery imaging), MRI has become one of the preferred non-invasive modalities to study cardiac diseases. In this paper an overview of the versatility of delayed contrast-enhanced MRI for investigating cardiac diseases is given. (orig.)

  13. MRI and echocardiography in the diagnosis of cardiac amyloidosis

    International Nuclear Information System (INIS)

    Wang Jing; Kong Xiangquan; Zhou Guofeng; Xu Haibo; Chang Dandan; Feng Yiming; Liu Dingxi; Zhang Li; Xie Mingxing

    2010-01-01

    Objective: To assess the values of MRI and echocardiography for the diagnosis of cardiac amyloidosis (CA). Methods: Eleven cases with CA proved pathologically performed MRI and echocardiography, the findings were analyzed retrospectively. Results: The characteristic features of cardiac amyloidosis on MRI and echocardiography were: diffuse slight myocardial thickening of the left ventricular wall and interventricular septum (11 cases), slight myocardial thickening of the interatrial septum (5 cases), increased left ventricular mass (7 cases), enlarged left atrium (7 cases), impaired ventricular systolic and diastolic function (10 cases), pleural and pericardial effusions (11 and 9 cases). Echocardiography showed that myocardium was hyperechoic and presented as ground glass with some spotty hyperechoes in 6 cases. MRI revealed a distinct diffuse delayed enhancement of subendocardial and entire myocardium in 8 cases. Conclusion: Doppler echocardiography is the first-choice imaging technique and cardiac magnetic resonance imaging can provide more information for the diagnosis of CA. (authors)

  14. MRI in cardiac sarcoidosis and amyloidosis; MRT bei kardialer Sarkoidose und Amyloidose

    Energy Technology Data Exchange (ETDEWEB)

    Bauner, K.U. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Wintersperger, B. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); University of Toronto, Department of Medical Imaging, Toronto General Hospital, Toronto, ON (Canada)

    2013-01-15

    Sarcoidosis and amyloidosis are both multisystem disorders, which may involve the heart; however, isolated cardiac disease is rare. Diagnosis of cardiac sarcoidosis and amyloidosis is crucial because the patient prognosis is dependent on cardiac involvement and early treatment. Echocardiography is the first line imaging modality in the diagnostic work-up of both diseases, possibly giving hints towards the correct diagnosis. Besides myocardial biopsy and radionuclide studies cardiac magnetic resonance imaging (MRI) is routinely performed in patients suspect of having infiltrative cardiomyopathy. The T1 mapping procedure is currently being evaluated as a new technique for detection and quantification of global myocardial enhancement, as seen in cardiac amyloidosis. Sensitivities and specificities for detection of cardiac sarcoidosis and amyloidosis can be significantly improved by MRI, especially with late gadolinium enhancement (LGE) imaging. In cardiac sarcoidosis the use of LGE is outcome-related while in amyloidosis analysis of T1-mapping may be of prognostic value. If cardiac involvement in sarcoidosis or amyloidosis is suspected cardiac MRI including LGE should be performed for establishing the diagnosis. (orig.) [German] Die Sarkoidose und Amyloidose sind Multisystemerkrankungen, in deren Verlauf es zu einer kardialen Beteiligung kommen kann. Bildgebend wird als primaeres Verfahren die Echokardiographie eingesetzt. Zur weiteren Diagnostik wird neben der Biopsie und nuklearmedizinischen Verfahren v. a. die MRT herangezogen. Als neuere Technik zur Darstellung globaler diffuser Kontrastmittelanreicherungen, wie sie im Rahmen der Amyloidose vorkommen, wird z. Z. das T1-Mapping evaluiert. Durch den Einsatz der MRT, insbesondere des Late-Gadolinium-Enhancements (LGE), koennen die Sensitivitaet und Spezifitaet in der Diagnostik der kardialen Sarkoidose und Amyloidose entscheidend verbessert werden. Bei der Sarkoidose stellt das Vorhandensein eines LGE einen

  15. Evaluation of highly accelerated real-time cardiac cine MRI in tachycardia.

    Science.gov (United States)

    Bassett, Elwin C; Kholmovski, Eugene G; Wilson, Brent D; DiBella, Edward V R; Dosdall, Derek J; Ranjan, Ravi; McGann, Christopher J; Kim, Daniel

    2014-02-01

    Electrocardiogram (ECG)-gated breath-hold cine MRI is considered to be the gold standard test for the assessment of cardiac function. However, it may fail in patients with arrhythmia, impaired breath-hold capacity and poor ECG gating. Although ungated real-time cine MRI may mitigate these problems, commercially available real-time cine MRI pulse sequences using parallel imaging typically yield relatively poor spatiotemporal resolution because of their low image acquisition efficiency. As an extension of our previous work, the purpose of this study was to evaluate the diagnostic quality and accuracy of eight-fold-accelerated real-time cine MRI with compressed sensing (CS) for the quantification of cardiac function in tachycardia, where it is challenging for real-time cine MRI to provide sufficient spatiotemporal resolution. We evaluated the performances of eight-fold-accelerated cine MRI with CS, three-fold-accelerated real-time cine MRI with temporal generalized autocalibrating partially parallel acquisitions (TGRAPPA) and ECG-gated breath-hold cine MRI in 21 large animals with tachycardia (mean heart rate, 104 beats per minute) at 3T. For each cine MRI method, two expert readers evaluated the diagnostic quality in four categories (image quality, temporal fidelity of wall motion, artifacts and apparent noise) using a Likert scale (1-5, worst to best). One reader evaluated the left ventricular functional parameters. The diagnostic quality scores were significantly different between the three cine pulse sequences, except for the artifact level between CS and TGRAPPA real-time cine MRI. Both ECG-gated breath-hold cine MRI and eight-fold accelerated real-time cine MRI yielded all four scores of ≥ 3.0 (acceptable), whereas three-fold-accelerated real-time cine MRI yielded all scores below 3.0, except for artifact (3.0). The left ventricular ejection fraction (LVEF) measurements agreed better between ECG-gated cine MRI and eight-fold-accelerated real-time cine MRI

  16. Real-time MRI guidance of cardiac interventions.

    Science.gov (United States)

    Campbell-Washburn, Adrienne E; Tavallaei, Mohammad A; Pop, Mihaela; Grant, Elena K; Chubb, Henry; Rhode, Kawal; Wright, Graham A

    2017-10-01

    Cardiac magnetic resonance imaging (MRI) is appealing to guide complex cardiac procedures because it is ionizing radiation-free and offers flexible soft-tissue contrast. Interventional cardiac MR promises to improve existing procedures and enable new ones for complex arrhythmias, as well as congenital and structural heart disease. Guiding invasive procedures demands faster image acquisition, reconstruction and analysis, as well as intuitive intraprocedural display of imaging data. Standard cardiac MR techniques such as 3D anatomical imaging, cardiac function and flow, parameter mapping, and late-gadolinium enhancement can be used to gather valuable clinical data at various procedural stages. Rapid intraprocedural image analysis can extract and highlight critical information about interventional targets and outcomes. In some cases, real-time interactive imaging is used to provide a continuous stream of images displayed to interventionalists for dynamic device navigation. Alternatively, devices are navigated relative to a roadmap of major cardiac structures generated through fast segmentation and registration. Interventional devices can be visualized and tracked throughout a procedure with specialized imaging methods. In a clinical setting, advanced imaging must be integrated with other clinical tools and patient data. In order to perform these complex procedures, interventional cardiac MR relies on customized equipment, such as interactive imaging environments, in-room image display, audio communication, hemodynamic monitoring and recording systems, and electroanatomical mapping and ablation systems. Operating in this sophisticated environment requires coordination and planning. This review provides an overview of the imaging technology used in MRI-guided cardiac interventions. Specifically, this review outlines clinical targets, standard image acquisition and analysis tools, and the integration of these tools into clinical workflow. 1 Technical Efficacy: Stage 5 J

  17. Initial Experience With Simultaneous 18F-FDG PET/MRI in the Evaluation of Cardiac Sarcoidosis and Myocarditis.

    Science.gov (United States)

    Hanneman, Kate; Kadoch, Michael; Guo, Henry H; Jamali, Mehran; Quon, Andrew; Iagaru, Andrei; Herfkens, Robert

    2017-07-01

    The purpose of this study was to compare combined PET/MRI with PET/CT and cardiac MRI in the evaluation of cardiac sarcoidosis and myocarditis. Ten patients (4 men and 6 women; 56.1 ± 9.6 years old) were prospectively enrolled for evaluation of suspected cardiac sarcoidosis or myocarditis. Written informed consent was obtained. Following administration of 9.9 ± 0.9 mCi F-FDG, patients underwent standard cardiac PET/CT followed by combined PET/MRI using a simultaneous 3-T scanner. Cardiac MRI sequences included ECG-triggered cine SSFP, T2-weighted, and late gadolinium-enhanced imaging. Myocardial involvement was assessed with separate analysis of combined PET/MRI, PET/CT, and cardiac MRI data using dedicated postprocessing software. Estimates of radiation dose were derived from the applied doses of F-FDG and CT protocol parameters. Imaging was acquired with a delay from F-FDG injection of 90.2 ± 27.4 minutes for PET/CT and 207.7 ± 40.3 minutes for PET/MRI. Total scan time for PET/MRI was significantly longer than for PET/CT (81.4 ± 14.8 vs 12.0 minutes, P PET/MRI compared with PET/CT (6.9 ± 0.6 vs 8.2 ± 1.1 mSv, P = 0.007). There was no significant difference in the number of positive cases identified between combined PET/MRI (n = 10 [100%]), PET/CT (n = 6 [60%]), and cardiac MRI (n = 8 [80%]), P = 0.091. Simultaneous cardiac PET/MRI is feasible in the evaluation of cardiac sarcoidosis and myocarditis achieving diagnostic image quality.

  18. Intramyocardial strain estimation from cardiac cine MRI.

    Science.gov (United States)

    Elnakib, Ahmed; Beache, Garth M; Gimel'farb, Georgy; El-Baz, Ayman

    2015-08-01

    Functional strain is one of the important clinical indicators for the quantification of heart performance and the early detection of cardiovascular diseases, and functional strain parameters are used to aid therapeutic decisions and follow-up evaluations after cardiac surgery. A comprehensive framework for deriving functional strain parameters at the endocardium, epicardium, and mid-wall of the left ventricle (LV) from conventional cine MRI data was developed and tested. Cine data were collected using short TR-/TE-balanced steady-state free precession acquisitions on a 1.5T Siemens Espree scanner. The LV wall borders are segmented using a level set-based deformable model guided by a stochastic force derived from a second-order Markov-Gibbs random field model that accounts for the object shape and appearance features. Then, the mid-wall of the segmented LV is determined based on estimating the centerline between the endocardium and epicardium of the LV. Finally, a geometrical Laplace-based method is proposed to track corresponding points on successive myocardial contours throughout the cardiac cycle in order to characterize the strain evolutions. The method was tested using simulated phantom images with predefined point locations of the LV wall throughout the cardiac cycle. The method was tested on 30 in vivo datasets to evaluate the feasibility of the proposed framework to index functional strain parameters. The cine MRI-based model agreed with the ground truth for functional metrics to within 0.30 % for indexing the peak systolic strain change and 0.29 % (per unit time) for indexing systolic and diastolic strain rates. The method was feasible for in vivo extraction of functional strain parameters. Strain indexes of the endocardium, mid-wall, and epicardium can be derived from routine cine images using automated techniques, thereby improving the utility of cine MRI data for characterization of myocardial function. Unlike traditional texture-based tracking, the

  19. Real-time QRS detection using integrated variance for ECG gated cardiac MRI

    Directory of Open Access Journals (Sweden)

    Schmidt Marcus

    2016-09-01

    Full Text Available During magnetic resonance imaging (MRI, a patient’s vital signs are required for different purposes. In cardiac MRI (CMR, an electrocardiogram (ECG of the patient is required for triggering the image acquisition process. However, a reliable QRS detection of an ECG signal acquired inside an MRI scanner is a challenging task due to the magnetohydrodynamic (MHD effect which interferes with the ECG. The aim of this work was to develop a reliable QRS detector usable inside the MRI which also fulfills the standards for medical devices (IEC 60601-2-27. Therefore, a novel real-time QRS detector based on integrated variance measurements is presented. The algorithm was trained on ANSI/AAMI EC13 test waveforms and was then applied to two databases with 12-lead ECG signals recorded inside and outside an MRI scanner. Reliable results for both databases were achieved for the ECG signals recorded inside (DBMRI: sensitivity Se = 99.94%, positive predictive value +P = 99.84% and outside (DBInCarT: Se = 99.29%, +P = 99.72% the MRI. Due to the accurate R-peak detection in real-time this can be used for monitoring and triggering in MRI exams.

  20. MRI with cardiac pacing devices – Safety in clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Kaasalainen, Touko, E-mail: touko.kaasalainen@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Department of Physics, University of Helsinki (Finland); Pakarinen, Sami, E-mail: sami.pakarinen@hus.fi [HUS Department of Cardiology, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Kivistö, Sari, E-mail: sari.kivisto@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Holmström, Miia, E-mail: miia.holmstrom@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Hänninen, Helena, E-mail: helena.hanninen@hus.fi [HUS Department of Cardiology, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Peltonen, Juha, E-mail: juha.peltonen@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Department of Biomedical Engineering and Computational Science, School of Science, Aalto University, Helsinki (Finland); Lauerma, Kirsi, E-mail: kirsi.lauerma@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Sipilä, Outi, E-mail: outi.sipila@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland)

    2014-08-15

    Objectives: The aim of this study was to introduce a single centre “real life” experience of performing MRI examinations in clinical practice on patients with cardiac pacemaker systems. Additionally, we aimed to evaluate the safety of using a dedicated safety protocol for these patients. Materials and methods: We used a 1.5 T MRI scanner to conduct 68 MRI scans of different body regions in patients with pacing systems. Of the cardiac devices, 32% were MR-conditional, whereas the remaining 68% were MR-unsafe. We recorded the functional parameters of the devices prior, immediately after, and approximately one month after the MRI scanning, and compared the device parameters to the baseline values. Results: All MRI examinations were completed safely, and each device could be interrogated normally following the MRI. We observed no changes in the programmed parameters of the devices. For most of the participants, the distributions of the immediate and one-month changes in the device parameters were within 20% of the baseline values, although some changes approached clinically important thresholds. Furthermore, we observed no differences in the variable changes between MR-conditional and MR-unsafe pacing systems, or between scans of the thorax area and other scanned areas. Conclusion: MRI in patients with MR-conditional pacing systems and selected MR-unsafe systems could be performed safely under strict conditions in this study.

  1. Radiotherapy beyond cancer: Target localization in real-time MRI and treatment planning for cardiac radiosurgery

    International Nuclear Information System (INIS)

    Ipsen, S.; Blanck, O.; Rades, D.; Oborn, B.; Bode, F.; Liney, G.; Hunold, P.; Schweikard, A.; Keall, P. J.

    2014-01-01

    Purpose: Atrial fibrillation (AFib) is the most common cardiac arrhythmia that affects millions of patients world-wide. AFib is usually treated with minimally invasive, time consuming catheter ablation techniques. While recently noninvasive radiosurgery to the pulmonary vein antrum (PVA) in the left atrium has been proposed for AFib treatment, precise target location during treatment is challenging due to complex respiratory and cardiac motion. A MRI linear accelerator (MRI-Linac) could solve the problems of motion tracking and compensation using real-time image guidance. In this study, the authors quantified target motion ranges on cardiac magnetic resonance imaging (MRI) and analyzed the dosimetric benefits of margin reduction assuming real-time motion compensation was applied. Methods: For the imaging study, six human subjects underwent real-time cardiac MRI under free breathing. The target motion was analyzed retrospectively using a template matching algorithm. The planning study was conducted on a CT of an AFib patient with a centrally located esophagus undergoing catheter ablation, representing an ideal case for cardiac radiosurgery. The target definition was similar to the ablation lesions at the PVA created during catheter treatment. Safety margins of 0 mm (perfect tracking) to 8 mm (untracked respiratory motion) were added to the target, defining the planning target volume (PTV). For each margin, a 30 Gy single fraction IMRT plan was generated. Additionally, the influence of 1 and 3 T magnetic fields on the treatment beam delivery was simulated using Monte Carlo calculations to determine the dosimetric impact of MRI guidance for two different Linac positions. Results: Real-time cardiac MRI showed mean respiratory target motion of 10.2 mm (superior–inferior), 2.4 mm (anterior–posterior), and 2 mm (left–right). The planning study showed that increasing safety margins to encompass untracked respiratory motion leads to overlapping structures even in the

  2. Radiotherapy beyond cancer: Target localization in real-time MRI and treatment planning for cardiac radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Ipsen, S. [Radiation Physics Laboratory, Sydney Medical School, The University of Sydney, Sydney, New South Wales 2006, Australia and Institute for Robotics and Cognitive Systems, University of Luebeck, Luebeck 23562 (Germany); Blanck, O.; Rades, D. [Department of Radiation Oncology, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck, Luebeck 23562 (Germany); Oborn, B. [Illawarra Cancer Care Centre (ICCC), Wollongong, New South Wales 2500, Australia and Centre for Medical Radiation Physics (CMRP), University of Wollongong, Wollongong, New South Wales 2500 (Australia); Bode, F. [Medical Department II, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck, Luebeck 23562 (Germany); Liney, G. [Ingham Institute for Applied Medical Research, Liverpool Hospital, Liverpool, New South Wales 2170 (Australia); Hunold, P. [Department of Radiology and Nuclear Medicine, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck, Luebeck 23562 (Germany); Schweikard, A. [Institute for Robotics and Cognitive Systems, University of Luebeck, Luebeck 23562 (Germany); Keall, P. J., E-mail: paul.keall@sydney.edu.au [Radiation Physics Laboratory, Sydney Medical School, The University of Sydney, Sydney, New South Wales 2006 (Australia)

    2014-12-15

    Purpose: Atrial fibrillation (AFib) is the most common cardiac arrhythmia that affects millions of patients world-wide. AFib is usually treated with minimally invasive, time consuming catheter ablation techniques. While recently noninvasive radiosurgery to the pulmonary vein antrum (PVA) in the left atrium has been proposed for AFib treatment, precise target location during treatment is challenging due to complex respiratory and cardiac motion. A MRI linear accelerator (MRI-Linac) could solve the problems of motion tracking and compensation using real-time image guidance. In this study, the authors quantified target motion ranges on cardiac magnetic resonance imaging (MRI) and analyzed the dosimetric benefits of margin reduction assuming real-time motion compensation was applied. Methods: For the imaging study, six human subjects underwent real-time cardiac MRI under free breathing. The target motion was analyzed retrospectively using a template matching algorithm. The planning study was conducted on a CT of an AFib patient with a centrally located esophagus undergoing catheter ablation, representing an ideal case for cardiac radiosurgery. The target definition was similar to the ablation lesions at the PVA created during catheter treatment. Safety margins of 0 mm (perfect tracking) to 8 mm (untracked respiratory motion) were added to the target, defining the planning target volume (PTV). For each margin, a 30 Gy single fraction IMRT plan was generated. Additionally, the influence of 1 and 3 T magnetic fields on the treatment beam delivery was simulated using Monte Carlo calculations to determine the dosimetric impact of MRI guidance for two different Linac positions. Results: Real-time cardiac MRI showed mean respiratory target motion of 10.2 mm (superior–inferior), 2.4 mm (anterior–posterior), and 2 mm (left–right). The planning study showed that increasing safety margins to encompass untracked respiratory motion leads to overlapping structures even in the

  3. Radiotherapy beyond cancer: target localization in real-time MRI and treatment planning for cardiac radiosurgery.

    Science.gov (United States)

    Ipsen, S; Blanck, O; Oborn, B; Bode, F; Liney, G; Hunold, P; Rades, D; Schweikard, A; Keall, P J

    2014-12-01

    Atrial fibrillation (AFib) is the most common cardiac arrhythmia that affects millions of patients world-wide. AFib is usually treated with minimally invasive, time consuming catheter ablation techniques. While recently noninvasive radiosurgery to the pulmonary vein antrum (PVA) in the left atrium has been proposed for AFib treatment, precise target location during treatment is challenging due to complex respiratory and cardiac motion. A MRI linear accelerator (MRI-Linac) could solve the problems of motion tracking and compensation using real-time image guidance. In this study, the authors quantified target motion ranges on cardiac magnetic resonance imaging (MRI) and analyzed the dosimetric benefits of margin reduction assuming real-time motion compensation was applied. For the imaging study, six human subjects underwent real-time cardiac MRI under free breathing. The target motion was analyzed retrospectively using a template matching algorithm. The planning study was conducted on a CT of an AFib patient with a centrally located esophagus undergoing catheter ablation, representing an ideal case for cardiac radiosurgery. The target definition was similar to the ablation lesions at the PVA created during catheter treatment. Safety margins of 0 mm (perfect tracking) to 8 mm (untracked respiratory motion) were added to the target, defining the planning target volume (PTV). For each margin, a 30 Gy single fraction IMRT plan was generated. Additionally, the influence of 1 and 3 T magnetic fields on the treatment beam delivery was simulated using Monte Carlo calculations to determine the dosimetric impact of MRI guidance for two different Linac positions. Real-time cardiac MRI showed mean respiratory target motion of 10.2 mm (superior-inferior), 2.4 mm (anterior-posterior), and 2 mm (left-right). The planning study showed that increasing safety margins to encompass untracked respiratory motion leads to overlapping structures even in the ideal scenario, compromising

  4. Applications of cardiac MRI in pediatric heart diseases

    International Nuclear Information System (INIS)

    Tao Xiaojuan; Zeng Jinjin; Sun Jihang; Cheng Hua; Yin Guangheng

    2009-01-01

    Objective: To evaluate the value of magnetic resonance imaging in pediatric heart diseases. Methods: Ninety-seven cases received cardiac MR scanning in this present study. The age range was 2 day to 13 years including 62 boys and 35 girls, the median age was 6 years. They were performed on h 5 T scanner with cardiac phased-array coil and VCG. Results: Eighty-five of the 97 cases were positive. Those positive findings included cardiomyopathy in 41 cases, congenital heart disease in 20 cases, constrictive pericarditis in 4 cases, pericardiac effusions with or without other cardiovascular diseases in 17 cases, cardiac tumor in 2 cases,thrombus in 3 cases and in 5 other cases. Conclusion: Cardiac MRI is an excellent imaging modality for the anatomical and functional abnormalities of pediatric heart diseases. (authors)

  5. Highly-accelerated self-gated free-breathing 3D cardiac cine MRI: validation in assessment of left ventricular function.

    Science.gov (United States)

    Liu, Jing; Feng, Li; Shen, Hsin-Wei; Zhu, Chengcheng; Wang, Yan; Mukai, Kanae; Brooks, Gabriel C; Ordovas, Karen; Saloner, David

    2017-08-01

    This work presents a highly-accelerated, self-gated, free-breathing 3D cardiac cine MRI method for cardiac function assessment. A golden-ratio profile based variable-density, pseudo-random, Cartesian undersampling scheme was implemented for continuous 3D data acquisition. Respiratory self-gating was achieved by deriving motion signal from the acquired MRI data. A multi-coil compressed sensing technique was employed to reconstruct 4D images (3D+time). 3D cardiac cine imaging with self-gating was compared to bellows gating and the clinical standard breath-held 2D cine imaging for evaluation of self-gating accuracy, image quality, and cardiac function in eight volunteers. Reproducibility of 3D imaging was assessed. Self-gated 3D imaging provided an image quality score of 3.4 ± 0.7 vs 4.0 ± 0 with the 2D method (p = 0.06). It determined left ventricular end-systolic volume as 42.4 ± 11.5 mL, end-diastolic volume as 111.1 ± 24.7 mL, and ejection fraction as 62.0 ± 3.1%, which were comparable to the 2D method, with bias ± 1.96 × SD of -0.8 ± 7.5 mL (p = 0.90), 2.6 ± 3.3 mL (p = 0.84) and 1.4 ± 6.4% (p = 0.45), respectively. The proposed 3D cardiac cine imaging method enables reliable respiratory self-gating performance with good reproducibility, and provides comparable image quality and functional measurements to 2D imaging, suggesting that self-gated, free-breathing 3D cardiac cine MRI framework is promising for improved patient comfort and cardiac MRI scan efficiency.

  6. Automatic initialization and quality control of large-scale cardiac MRI segmentations.

    Science.gov (United States)

    Albà, Xènia; Lekadir, Karim; Pereañez, Marco; Medrano-Gracia, Pau; Young, Alistair A; Frangi, Alejandro F

    2018-01-01

    Continuous advances in imaging technologies enable ever more comprehensive phenotyping of human anatomy and physiology. Concomitant reduction of imaging costs has resulted in widespread use of imaging in large clinical trials and population imaging studies. Magnetic Resonance Imaging (MRI), in particular, offers one-stop-shop multidimensional biomarkers of cardiovascular physiology and pathology. A wide range of analysis methods offer sophisticated cardiac image assessment and quantification for clinical and research studies. However, most methods have only been evaluated on relatively small databases often not accessible for open and fair benchmarking. Consequently, published performance indices are not directly comparable across studies and their translation and scalability to large clinical trials or population imaging cohorts is uncertain. Most existing techniques still rely on considerable manual intervention for the initialization and quality control of the segmentation process, becoming prohibitive when dealing with thousands of images. The contributions of this paper are three-fold. First, we propose a fully automatic method for initializing cardiac MRI segmentation, by using image features and random forests regression to predict an initial position of the heart and key anatomical landmarks in an MRI volume. In processing a full imaging database, the technique predicts the optimal corrective displacements and positions in relation to the initial rough intersections of the long and short axis images. Second, we introduce for the first time a quality control measure capable of identifying incorrect cardiac segmentations with no visual assessment. The method uses statistical, pattern and fractal descriptors in a random forest classifier to detect failures to be corrected or removed from subsequent statistical analysis. Finally, we validate these new techniques within a full pipeline for cardiac segmentation applicable to large-scale cardiac MRI databases. The

  7. Imaging technique and current status of valvular heart disease using cardiac MRI

    International Nuclear Information System (INIS)

    Lotz, J.; Sohns, J.M.

    2013-01-01

    The main indications for cardiac magnetic resonance imaging (MRI) in the evaluation of valvular heart disease are pathologies of the aortic and pulmonary valve. For mitral and tricuspid valve pathologies MRI is not the first line modality as these are usually well visualized by echocardiography. The advantages of MRI in valvular heart disease are a high reliability in the evaluation of ventricular volumes and function as well as the assessment of the perivalvular arterial or atrial structures. This reliability and the limitless access to any imaging plane partially compensates for the lower temporal and spatial resolution in comparison to echocardiography. In patients with congenital heart disease, cardiac MRI is established as a valuable diagnostic tool in daily clinical management, especially for the evaluation of pulmonary valve defects. Nevertheless, echocardiography remains the first-line diagnostic imaging tool for the foreseeable future. (orig.) [de

  8. Compressed sensing reconstruction of cardiac cine MRI using golden angle spiral trajectories.

    Science.gov (United States)

    Tolouee, Azar; Alirezaie, Javad; Babyn, Paul

    2015-11-01

    In dynamic cardiac cine Magnetic Resonance Imaging (MRI), the spatiotemporal resolution is limited by the low imaging speed. Compressed sensing (CS) theory has been applied to improve the imaging speed and thus the spatiotemporal resolution. The purpose of this paper is to improve CS reconstruction of under sampled data by exploiting spatiotemporal sparsity and efficient spiral trajectories. We extend k-t sparse algorithm to spiral trajectories to achieve high spatio temporal resolutions in cardiac cine imaging. We have exploited spatiotemporal sparsity of cardiac cine MRI by applying a 2D+time wavelet-Fourier transform. For efficient coverage of k-space, we have used a modified version of multi shot (interleaved) spirals trajectories. In order to reduce incoherent aliasing artifact, we use different random undersampling pattern for each temporal frame. Finally, we have used nonuniform fast Fourier transform (NUFFT) algorithm to reconstruct the image from the non-uniformly acquired samples. The proposed approach was tested in simulated and cardiac cine MRI data. Results show that higher acceleration factors with improved image quality can be obtained with the proposed approach in comparison to the existing state-of-the-art method. The flexibility of the introduced method should allow it to be used not only for the challenging case of cardiac imaging, but also for other patient motion where the patient moves or breathes during acquisition. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Highly-Accelerated Real-Time Cardiac Cine MRI Using k-t SPARSE-SENSE

    Science.gov (United States)

    Feng, Li; Srichai, Monvadi B.; Lim, Ruth P.; Harrison, Alexis; King, Wilson; Adluru, Ganesh; Dibella, Edward VR.; Sodickson, Daniel K.; Otazo, Ricardo; Kim, Daniel

    2012-01-01

    For patients with impaired breath-hold capacity and/or arrhythmias, real-time cine MRI may be more clinically useful than breath-hold cine MRI. However, commercially available real-time cine MRI methods using parallel imaging typically yield relatively poor spatio-temporal resolution due to their low image acquisition speed. We sought to achieve relatively high spatial resolution (~2.5mm × 2.5mm) and temporal resolution (~40ms), to produce high-quality real-time cine MR images that could be applied clinically for wall motion assessment and measurement of left ventricular (LV) function. In this work, we present an 8-fold accelerated real-time cardiac cine MRI pulse sequence using a combination of compressed sensing and parallel imaging (k-t SPARSE-SENSE). Compared with reference, breath-hold cine MRI, our 8-fold accelerated real-time cine MRI produced significantly worse qualitative grades (1–5 scale), but its image quality and temporal fidelity scores were above 3.0 (adequate) and artifacts and noise scores were below 3.0 (moderate), suggesting that acceptable diagnostic image quality can be achieved. Additionally, both 8-fold accelerated real-time cine and breath-hold cine MRI yielded comparable LV function measurements, with coefficient of variation cine MRI with k-t SPARSE-SENSE is a promising modality for rapid imaging of myocardial function. PMID:22887290

  10. Highly accelerated real-time cardiac cine MRI using k-t SPARSE-SENSE.

    Science.gov (United States)

    Feng, Li; Srichai, Monvadi B; Lim, Ruth P; Harrison, Alexis; King, Wilson; Adluru, Ganesh; Dibella, Edward V R; Sodickson, Daniel K; Otazo, Ricardo; Kim, Daniel

    2013-07-01

    For patients with impaired breath-hold capacity and/or arrhythmias, real-time cine MRI may be more clinically useful than breath-hold cine MRI. However, commercially available real-time cine MRI methods using parallel imaging typically yield relatively poor spatio-temporal resolution due to their low image acquisition speed. We sought to achieve relatively high spatial resolution (∼2.5 × 2.5 mm(2)) and temporal resolution (∼40 ms), to produce high-quality real-time cine MR images that could be applied clinically for wall motion assessment and measurement of left ventricular function. In this work, we present an eightfold accelerated real-time cardiac cine MRI pulse sequence using a combination of compressed sensing and parallel imaging (k-t SPARSE-SENSE). Compared with reference, breath-hold cine MRI, our eightfold accelerated real-time cine MRI produced significantly worse qualitative grades (1-5 scale), but its image quality and temporal fidelity scores were above 3.0 (adequate) and artifacts and noise scores were below 3.0 (moderate), suggesting that acceptable diagnostic image quality can be achieved. Additionally, both eightfold accelerated real-time cine and breath-hold cine MRI yielded comparable left ventricular function measurements, with coefficient of variation cine MRI with k-t SPARSE-SENSE is a promising modality for rapid imaging of myocardial function. Copyright © 2012 Wiley Periodicals, Inc.

  11. Heart MRI

    Science.gov (United States)

    Magnetic resonance imaging - cardiac; Magnetic resonance imaging - heart; Nuclear magnetic resonance - cardiac; NMR - cardiac; MRI of the heart; Cardiomyopathy - MRI; Heart failure - MRI; Congenital heart disease - MRI

  12. Left atrial dysfunction in type 2 diabetes mellitus: insights from cardiac MRI

    Energy Technology Data Exchange (ETDEWEB)

    Graca, Bruno; Donato, Paulo; Caseiro-Alves, Filipe [University of Coimbra, Faculty of Medicine, Coimbra (Portugal); Coimbra' s Hospital Centre and University, Medical Imaging Department, Coimbra (Portugal); Joao Ferreira, Maria [University of Coimbra, Faculty of Medicine, Coimbra (Portugal); Coimbra' s Hospital Centre and University, Cardiology Department, Coimbra (Portugal); Gomes, Leonor [University of Coimbra, Faculty of Medicine, Coimbra (Portugal); Coimbra' s Hospital Centre and University, Endocrinology Department, Coimbra (Portugal); Castelo-Branco, Miguel [University of Coimbra, Faculty of Medicine, Coimbra (Portugal)

    2014-11-15

    The left atrium (LA) modulates left ventricular filling through reservoir, conduit and booster pump functions. Only limited data exist on LA involvement in type 2 diabetes mellitus (DM2). This study sought to assess LA function in asymptomatic DM2 with cardiac MRI. We hypothesized that cardiac MRI can detect LA dysfunction in asymptomatic DM2. Forty-five patients with asymptomatic DM2 and 24 normoglycaemic controls were studied. MRI cine imaging was performed to measure LA maximal and minimal volumes. A flow-sensitive phase-contrast gradient-echo sequence was used for flow measurements perpendicular to the orifice of the mitral valve, to quantify active LA stroke volume. LA total, passive and active emptying volumes and fractions were calculated. LA reservoir function, namely LA total ejection fraction, was significantly greater in controls compared to patients with DM2 (62.2 ± 5.2 vs 57.0 ± 7.6 %, P = 0.004). LA passive ejection fraction was also greater in the controls (26.2 ± 9.5 vs 16.1 ± 11.0 %, P < 0.001). Regarding parameters of LA booster pump function, LA active ejection fraction was not significantly different between groups. DM2 was demonstrated to be an independent determinant of LA function. Cardiac MRI enables the detection of LA dysfunction in asymptomatic DM2, characterized by a reduction in LA reservoir and conduit functions. (orig.)

  13. Manifold learning based ECG-free free-breathing cardiac CINE MRI.

    Science.gov (United States)

    Usman, Muhammad; Atkinson, David; Kolbitsch, Christoph; Schaeffter, Tobias; Prieto, Claudia

    2015-06-01

    To present and validate a manifold learning (ML)-based method that can estimate both cardiac and respiratory navigator signals from electrocardiogram (ECG)-free free-breathing cardiac magnetic resonance imaging (MRI) data to achieve self-gated retrospective CINE reconstruction. In this work the use of the ML method is demonstrated for 2D cardiac CINE to achieve both cardiac and respiratory self-gating without the need of an external navigator or ECG signal. This is achieved by sequentially applying ML to two sets of retrospectively reconstructed real-time images with differing temporal resolutions. A 1D cardiac signal is estimated by applying ML to high temporal resolution real-time images reconstructed from the acquired data. Using the estimated cardiac signal, a 1D respiratory signal was obtained by applying the ML method to low temporal resolution images reconstructed from the same acquired data for each cardiac cycle. Data were acquired in five volunteers with a 2D golden angle radial trajectory in a balanced steady-state free precession (b-SSFP) acquisition. The accuracy of the estimated cardiac signal was calculated as the standard deviation of the temporal difference between the estimated signal and the recorded ECG. The correlation between the estimated respiratory signal and standard pencil beam navigator signal was evaluated. Gated CINE reconstructions (20 cardiac phases per cycle, temporal resolution ∼30 msec) using the estimated cardiac and respiratory signals were qualitatively compared against conventional ECG-gated breath-hold CINE acquisitions. Accurate cardiac signals were estimated with the proposed method, with an error standard deviation in comparison to ECG lower than 20 msec. Respiratory signals estimated with the proposed method achieved a mean cross-correlation of 94% with respect to standard pencil beam navigator signals. Good quality visual scores of 2.80 ± 0.45 (scores from 0, bad, to 4, excellent quality) were observed for the

  14. An Overview of Techniques for Cardiac Left Ventricle Segmentation on Short-Axis MRI

    Directory of Open Access Journals (Sweden)

    Krasnobaev Arseny

    2016-01-01

    Full Text Available Nowadays, heart diseases are the leading cause of death. Left ventricle segmentation of a human heart in magnetic resonance images (MRI is a crucial step in both cardiac diseases diagnostics and heart internal structure reconstruction. It allows estimating such important parameters as ejection faction, left ventricle myocardium mass, stroke volume, etc. In addition, left ventricle segmentation helps to construct the personalized heart computational models in order to conduct the numerical simulations. At present, the fully automated cardiac segmentation methods still do not meet the accuracy requirements. We present an overview of left ventricle segmentation algorithms on short-axis MRI. A wide variety of completely different approaches are used for cardiac segmentation, including machine learning, graph-based methods, deformable models, and low-level heuristics. The current state-of-the-art technique is a combination of deformable models with advanced machine learning methods, such as deep learning or Markov random fields. We expect that approaches based on deep belief networks are the most promising ones because the main training process of networks with this architecture can be performed on the unlabelled data. In order to improve the quality of left ventricle segmentation algorithms, we need more datasets with labelled cardiac MRI data in open access.

  15. Estimation of cardiac motion in cine-MRI sequences by correlation transform optical flow of monogenic features distance

    Science.gov (United States)

    Gao, Bin; Liu, Wanyu; Wang, Liang; Liu, Zhengjun; Croisille, Pierre; Delachartre, Philippe; Clarysse, Patrick

    2016-12-01

    Cine-MRI is widely used for the analysis of cardiac function in clinical routine, because of its high soft tissue contrast and relatively short acquisition time in comparison with other cardiac MRI techniques. The gray level distribution in cardiac cine-MRI is relatively homogenous within the myocardium, and can therefore make motion quantification difficult. To ensure that the motion estimation problem is well posed, more image features have to be considered. This work is inspired by a method previously developed for color image processing. The monogenic signal provides a framework to estimate the local phase, orientation, and amplitude, of an image, three features which locally characterize the 2D intensity profile. The independent monogenic features are combined into a 3D matrix for motion estimation. To improve motion estimation accuracy, we chose the zero-mean normalized cross-correlation as a matching measure, and implemented a bilateral filter for denoising and edge-preservation. The monogenic features distance is used in lieu of the color space distance in the bilateral filter. Results obtained from four realistic simulated sequences outperformed two other state of the art methods even in the presence of noise. The motion estimation errors (end point error) using our proposed method were reduced by about 20% in comparison with those obtained by the other tested methods. The new methodology was evaluated on four clinical sequences from patients presenting with cardiac motion dysfunctions and one healthy volunteer. The derived strain fields were analyzed favorably in their ability to identify myocardial regions with impaired motion.

  16. An eight-year prospective controlled study about the safety and diagnostic value of cardiac and non-cardiac 1.5-T MRI in patients with a conventional pacemaker or a conventional implantable cardioverter defibrillator.

    Science.gov (United States)

    Lupo, Pierpaolo; Cappato, Riccardo; Di Leo, Giovanni; Secchi, Francesco; Papini, Giacomo D E; Foresti, Sara; Ali, Hussam; De Ambroggi, Guido M G; Sorgente, Antonio; Epicoco, Gianluca; Cannaò, Paola M; Sardanelli, Francesco

    2018-06-01

    To investigate safety and diagnostic value of 1.5-T MRI in carriers of conventional pacemaker (cPM) or conventional implantable defibrillator (cICD). We prospectively compared cPM/cICD-carriers undergoing MRI (study group, SG), excluding those device-dependent or implanted cPM/cICD-carriers undergoing chest x-ray, CT or follow-up (reference group, RG). 142 MRI (55 cardiac) were performed in 120 patients with cPM (n=71) or cICD (n=71). In the RG 98 measurements were performed in 95 patients with cPM (n=40) or cICD (n=58). No adverse events were observed. No MRI prolonged/interrupted. All cPM/cICD were correctly reprogrammed after MRI without malfunctions. One temporary communication failure was observed in one cPM-carrier. Immediately after MRI, 12/14 device interrogation parameters did not change significantly (clinically negligible changes of battery voltage and cICD charging time), without significant variations for SG versus RG. Three-12 months after MRI, 9/11 device interrogation parameters did not change significantly (clinically negligible changes of battery impedance/voltage). Non-significant changes of three markers of myocardial necrosis. Non-cardiac MRI: 82/87 diagnostic without artefacts; 4/87 diagnostic with artefacts; 1/87 partially diagnostic. Cardiac MRI: in cPM-carriers, 14/15 diagnostic with artefacts, 1/15 partially diagnostic; in cICD-carriers, 9/40 diagnostic with artefacts, 22 partially diagnostic, nine non-diagnostic. A favourable risk-benefit ratio of 1.5-T MRI in cPM/cICD carriers was reported. • Cooperation between radiologists and cardiac electrophysiologists allowed safe 1.5-T MRI in cPM/cICD-carriers. • No adverse events for 142 MRI in 71 cPM-carriers and 71 cICD-carriers. • Ninety-nine per cent (86/87) of non-cardiac MRI in cPM/cICD-carriers were diagnostic. • All cPM-carrier cardiac MRIs had artefacts, 14 examinations diagnostic, 1 partially diagnostic. • Twenty-three per cent (9/40) of cardiac MRI in cICD-carriers were non-diagnostic.

  17. Assessment of cardiac morphology and ventricular function in healthy Chinese individuals using MRI

    International Nuclear Information System (INIS)

    Lu Minjie; Zhao Shihua; Jiang Shiliang

    2011-01-01

    Objective: To investigate reproducibility of cardiac MRI for assessment of cardiac morphology and ventricular function in selected normal Chinese Han population. Methods: Two hundred and sixty-nine normal volunteers underwent cardiac MRI using a 1.5 T MR system. HASTE and steady state free precession imaging were performed with long and short axis images and cine mode through the ventricle with wireless vector cardiac gating. The images were reviewed by two independent observers. The dimensions of cardiac chambers and ventricular function including ejection fraction (EF), end diastolic volume (EDV) , end systolic volume (ESV) and myocardial mass were evaluated. The data between male and female were compared by using two-tailed unpaired t test. Results: Total imaging time was (15±3) min. The anteroposterior diameter of the left atrium was (2.87±0.77) cm, the right atrial diameter perpendicular to the atrial septum was (3.61±0.57) cm, the end diastolic diameter of the left ventricle was (4.97± 0.52) cm, the end diastolic diameter of the right ventricle was (2.65±0.48) cm. On the left ventricle, EF was (60.62±7.08)%, EDV was (115.37±26.71) ml, ESV was (46.02±15.72) ml and LV mass was (82.97±24.03) g. On the right ventricle, EF was (47.73±6.50)%, EDV was (128.27±32.16) ml, ESV was (67.7±21.07) ml and RV mass was (48.24±13.42) g. There were no statistically significant differences in LVESV (P=0.144), LVEDV index (P=0.714), LVESV index (P=0.113), LVCI (P=0.199), RVEF (P=0.296) and RV mass (P=0.093), and statistically significant differences in other cardiac parameters between male and female. Conclusion: Cardiac MRI can provide useful information about cardiac function and morphology with a high level of reproducibility in normal Chinese Han population. (authors)

  18. Cardiac re-entry dynamics and self-termination in DT-MRI based model of Human Foetal Heart

    Science.gov (United States)

    Biktasheva, Irina V.; Anderson, Richard A.; Holden, Arun V.; Pervolaraki, Eleftheria; Wen, Fen Cai

    2018-02-01

    The effect of human foetal heart geometry and anisotropy on anatomy induced drift and self-termination of cardiac re-entry is studied here in MRI based 2D slice and 3D whole heart computer simulations. Isotropic and anisotropic models of 20 weeks of gestational age human foetal heart obtained from 100μm voxel diffusion tensor MRI data sets were used in the computer simulations. The fiber orientation angles of the heart were obtained from the orientation of the DT-MRI primary eigenvectors. In a spatially homogeneous electrophysiological monodomain model with the DT-MRI based heart geometries, cardiac re-entry was initiated at a prescribed location in a 2D slice, and in the 3D whole heart anatomy models. Excitation was described by simplified FitzHugh-Nagumo kinetics. In a slice of the heart, with propagation velocity twice as fast along the fibres than across the fibers, DT-MRI based fiber anisotropy changes the re-entry dynamics from pinned to an anatomical re-entry. In the 3D whole heart models, the fiber anisotropy changes cardiac re-entry dynamics from a persistent re-entry to the re-entry self-termination. The self-termination time depends on the re-entry’s initial position. In all the simulations with the DT-MRI based cardiac geometry, the anisotropy of the myocardial tissue shortens the time to re-entry self-termination several folds. The numerical simulations depend on the validity of the DT-MRI data set used. The ventricular wall showed the characteristic transmural rotation of the helix angle of the developed mammalian heart, while the fiber orientation in the atria was irregular.

  19. Modelling cardiac signal as a confound in EEG-fMRI and its application in focal epilepsy studies

    DEFF Research Database (Denmark)

    Liston, A. D.; Ellegaard Lund, Torben; Salek-Haddadi, A

    2006-01-01

    effects to be modelled, as effects of no interest. Our model is based on an over-complete basis set covering a linear relationship between cardiac-related MR signal and the phase of the cardiac cycle or time after pulse (TAP). This method showed that, on average, 24.6 +/- 10.9% of grey matter voxels......Cardiac noise has been shown to reduce the sensitivity of functional Magnetic Resonance Imaging (fMRI) to an experimental effect due to its confounding presence in the blood oxygenation level-dependent (BOLD) signal. Its effect is most severe in particular regions of the brain and a method is yet...... to take it into account in routine fMRI analysis. This paper reports the development of a general and robust technique to improve the reliability of EEG-fMRI studies to BOLD signal correlated with interictal epileptiform discharges (IEDs). In these studies, ECG is routinely recorded, enabling cardiac...

  20. A combined deep-learning and deformable-model approach to fully automatic segmentation of the left ventricle in cardiac MRI.

    Science.gov (United States)

    Avendi, M R; Kheradvar, Arash; Jafarkhani, Hamid

    2016-05-01

    Segmentation of the left ventricle (LV) from cardiac magnetic resonance imaging (MRI) datasets is an essential step for calculation of clinical indices such as ventricular volume and ejection fraction. In this work, we employ deep learning algorithms combined with deformable models to develop and evaluate a fully automatic LV segmentation tool from short-axis cardiac MRI datasets. The method employs deep learning algorithms to learn the segmentation task from the ground true data. Convolutional networks are employed to automatically detect the LV chamber in MRI dataset. Stacked autoencoders are used to infer the LV shape. The inferred shape is incorporated into deformable models to improve the accuracy and robustness of the segmentation. We validated our method using 45 cardiac MR datasets from the MICCAI 2009 LV segmentation challenge and showed that it outperforms the state-of-the art methods. Excellent agreement with the ground truth was achieved. Validation metrics, percentage of good contours, Dice metric, average perpendicular distance and conformity, were computed as 96.69%, 0.94, 1.81 mm and 0.86, versus those of 79.2-95.62%, 0.87-0.9, 1.76-2.97 mm and 0.67-0.78, obtained by other methods, respectively. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. The Adverse Events and Hemodynamic Effects of Adenosine-Based Cardiac MRI

    International Nuclear Information System (INIS)

    Voigtlander, Thomas; Magedanz, Annett; Schmermund, Axel; Bramlage, Peter; Elsaesser, Amelie; Kauczor, Hans-Ulrich; Mohrs, Oliver K.

    2011-01-01

    We wanted to prospectively assess the adverse events and hemodynamic effects associated with an intravenous adenosine infusion in patients with suspected or known coronary artery disease and who were undergoing cardiac MRI. One hundred and sixty-eight patients (64 ± 9 years) received adenosine (140 μg/kg/min) during cardiac MRI. Before and during the administration, the heart rate, systemic blood pressure, and oxygen saturation were monitored using a MRI-compatible system. We documented any signs and symptoms of potential adverse events. In total, 47 out of 168 patients (28%) experienced adverse effects, which were mostly mild or moderate. In 13 patients (8%), the adenosine infusion was discontinued due to intolerable dyspnea or chest pain. No high grade atrioventricular block, bronchospasm or other life-threatening adverse events occurred. The hemodynamic measurements showed a significant increase in the heart rate during adenosine infusion (69.3 ± 11.7 versus 82.4 ± 13.0 beats/min, respectively; p < 0.001). A significant but clinically irrelevant increase in oxygen saturation occurred during adenosine infusion (96 ± 1.9% versus 97 ± 1.3%, respectively; p < 0.001). The blood pressure did not significantly change during adenosine infusion (systolic: 142.8 ± 24.0 versus 140.9 ± 25.7 mmHg; diastolic: 80.2 ± 12.5 mmHg versus 78.9 ± 15.6, respectively). This study confirms the safety of adenosine infusion during cardiac MRI. A considerable proportion of all patients will experience minor adverse effects and some patients will not tolerate adenosine infusion. However, all adverse events can be successfully managed by a radiologist. The increased heart rate during adenosine infusion highlights the need to individually adjust the settings according to the patient, e.g., the number of slices of myocardial perfusion imaging.

  2. Cardiac MRI in mice at 9.4 Tesla with a transmit-receive surface coil and a cardiac-tailored intensity-correction algorithm.

    Science.gov (United States)

    Sosnovik, David E; Dai, Guangping; Nahrendorf, Matthias; Rosen, Bruce R; Seethamraju, Ravi

    2007-08-01

    To evaluate the use of a transmit-receive surface (TRS) coil and a cardiac-tailored intensity-correction algorithm for cardiac MRI in mice at 9.4 Tesla (9.4T). Fast low-angle shot (FLASH) cines, with and without delays alternating with nutations for tailored excitation (DANTE) tagging, were acquired in 13 mice. An intensity-correction algorithm was developed to compensate for the sensitivity profile of the surface coil, and was tailored to account for the unique distribution of noise and flow artifacts in cardiac MR images. Image quality was extremely high and allowed fine structures such as trabeculations, valve cusps, and coronary arteries to be clearly visualized. The tag lines created with the surface coil were also sharp and clearly visible. Application of the intensity-correction algorithm improved signal intensity, tissue contrast, and image quality even further. Importantly, the cardiac-tailored properties of the correction algorithm prevented noise and flow artifacts from being significantly amplified. The feasibility and value of cardiac MRI in mice with a TRS coil has been demonstrated. In addition, a cardiac-tailored intensity-correction algorithm has been developed and shown to improve image quality even further. The use of these techniques could produce significant potential benefits over a broad range of scanners, coil configurations, and field strengths. (c) 2007 Wiley-Liss, Inc.

  3. Self-gated fat-suppressed cardiac cine MRI.

    Science.gov (United States)

    Ingle, R Reeve; Santos, Juan M; Overall, William R; McConnell, Michael V; Hu, Bob S; Nishimura, Dwight G

    2015-05-01

    To develop a self-gated alternating repetition time balanced steady-state free precession (ATR-SSFP) pulse sequence for fat-suppressed cardiac cine imaging. Cardiac gating is computed retrospectively using acquired magnetic resonance self-gating data, enabling cine imaging without the need for electrocardiogram (ECG) gating. Modification of the slice-select rephasing gradients of an ATR-SSFP sequence enables the acquisition of a one-dimensional self-gating readout during the unused short repetition time (TR). Self-gating readouts are acquired during every TR of segmented, breath-held cardiac scans. A template-matching algorithm is designed to compute cardiac trigger points from the self-gating signals, and these trigger points are used for retrospective cine reconstruction. The proposed approach is compared with ECG-gated ATR-SSFP and balanced steady-state free precession in 10 volunteers and five patients. The difference of ECG and self-gating trigger times has a variability of 13 ± 11 ms (mean ± SD). Qualitative reviewer scoring and ranking indicate no statistically significant differences (P > 0.05) between self-gated and ECG-gated ATR-SSFP images. Quantitative blood-myocardial border sharpness is not significantly different among self-gated ATR-SSFP ( 0.61±0.15 mm -1), ECG-gated ATR-SSFP ( 0.61±0.15 mm -1), or conventional ECG-gated balanced steady-state free precession cine MRI ( 0.59±0.15 mm -1). The proposed self-gated ATR-SSFP sequence enables fat-suppressed cardiac cine imaging at 1.5 T without the need for ECG gating and without decreasing the imaging efficiency of ATR-SSFP. © 2014 Wiley Periodicals, Inc.

  4. Cardiac MRI in pulmonary artery hypertension: correlations between morphological and functional parameters and invasive measurements

    Energy Technology Data Exchange (ETDEWEB)

    Alunni, Jean-Philippe; Otal, Philippe; Rousseau, Herve; Chabbert, Valerie [CHU Rangueil, Department of Radiology, Toulouse (France); Degano, Bruno; Tetu, Laurent; Didier, Alain [CHU Larrey, Department of Pneumology, Toulouse (France); Arnaud, Catherine [CHU Rangueil, Department of Methods in Clinical Research, Toulouse (France); Blot-Souletie, Nathalie [CHU Rangueil, Department of Cardiology, Toulouse (France)

    2010-05-15

    To compare cardiac MRI with right heart catheterisation in patients with pulmonary hypertension (PH) and to evaluate its ability to assess PH severity. Forty patients were included. MRI included cine and phase-contrast sequences, study of ventricular function, cardiac cavity areas and ratios, position of the interventricular septum (IVS) in systole and diastole, and flow measurements. We defined four groups according to the severity of PH and three groups according to IVS position: A, normal position; B, abnormal in diastole; C, abnormal in diastole and systole. IVS position was correlated with pulmonary artery pressures and PVR (pulmonary vascular resistance). Median pulmonary artery pressures and resistance were significantly higher in patients with an abnormal septal position compared with those with a normal position. Correlations were good between the right ventricular ejection fraction and PVR, right ventricular end-systolic volume and PAP, percentage of right ventricular area change and PVR, and diastolic and systolic ventricular area ratio and PVR. These parameters were significantly associated with PH severity. Cardiac MRI can help to assess the severity of PH. (orig.)

  5. A comparison of left ventricular mass between two-dimensional echocardiography, using fundamental and tissue harmonic imaging, and cardiac MRI in patients with hypertension

    International Nuclear Information System (INIS)

    Alfakih, Khaled; Bloomer, Tim; Bainbridge, Samantha; Bainbridge, Gavin; Ridgway, John; Williams, Gordon; Sivananthan, Mohan

    2004-01-01

    Purpose: To compare left ventricular mass (LVM) as measured by two-dimensional (2D) echocardiography using two different calculation methods: truncated ellipse (TE) and area length (AL), in both fundamental and tissue harmonic imaging frequencies, to LVM as measured by, the current gold standard, cardiac magnetic resonance imaging (MRI). Turbo gradient echo (TGE) pulse sequence was utilized for MRI. Materials and methods: Thirty-two subjects with history of hypertension were recruited. The images were acquired, contours were traced and the LVM was calculated for all four different echocardiography methods as well as for the cardiac MRI method. The intra-observer variabilities were calculated. The four different echocardiography methods were compared to cardiac MRI using the method described by Bland and Altman. Results: Twenty-five subjects had adequate paired data sets. The mean LVM as measured by cardiac MRI was 162±55 g and for the four different echocardiography methods were: fundamental AL 165±55 g, harmonic AL 168±53 g, fundamental TE 148±50 g, harmonic TE 149±45 g. The intra-observer variability for cardiac MRI method, expressed as bias ± 1 standard deviation of the difference (S.D.D.), was 2.3±9.2 g and for the four different echocardiography methods were: fundamental TE 0.4±26.8 g, fundamental AL 0.6±27.0 g, harmonic TE 6.7±21.8 g, harmonic AL 6.4±22.9 g. The mean LVM for the AL method was closest to the cardiac MRI technique, while TE underestimated LVM. The 95% limits of agreement were consistently wide for all the 2D echocardiography modalities when compared with the cardiac MRI technique. Conclusion: The intra-observer variability in measurements of 2D echocardiographic LVM, together with the wide limits of agreement when compared to the gold standard (cardiac MRI) are sufficiently large to make serial estimates of LVM, of single patients or small groups of subjects, by 2D echocardiography, unreliable

  6. Cardiac tumors: optimal cardiac MR sequences and spectrum of imaging appearances.

    LENUS (Irish Health Repository)

    O'Donnell, David H

    2012-02-01

    OBJECTIVE: This article reviews the optimal cardiac MRI sequences for and the spectrum of imaging appearances of cardiac tumors. CONCLUSION: Recent technologic advances in cardiac MRI have resulted in the rapid acquisition of images of the heart with high spatial and temporal resolution and excellent myocardial tissue characterization. Cardiac MRI provides optimal assessment of the location, functional characteristics, and soft-tissue features of cardiac tumors, allowing accurate differentiation of benign and malignant lesions.

  7. Fetal cardiac cine imaging using highly accelerated dynamic MRI with retrospective motion correction and outlier rejection.

    Science.gov (United States)

    van Amerom, Joshua F P; Lloyd, David F A; Price, Anthony N; Kuklisova Murgasova, Maria; Aljabar, Paul; Malik, Shaihan J; Lohezic, Maelene; Rutherford, Mary A; Pushparajah, Kuberan; Razavi, Reza; Hajnal, Joseph V

    2018-01-01

    Development of a MRI acquisition and reconstruction strategy to depict fetal cardiac anatomy in the presence of maternal and fetal motion. The proposed strategy involves i) acquisition and reconstruction of highly accelerated dynamic MRI, followed by image-based ii) cardiac synchronization, iii) motion correction, iv) outlier rejection, and finally v) cardiac cine reconstruction. Postprocessing entirely was automated, aside from a user-defined region of interest delineating the fetal heart. The method was evaluated in 30 mid- to late gestational age singleton pregnancies scanned without maternal breath-hold. The combination of complementary acquisition/reconstruction and correction/rejection steps in the pipeline served to improve the quality of the reconstructed 2D cine images, resulting in increased visibility of small, dynamic anatomical features. Artifact-free cine images successfully were produced in 36 of 39 acquired data sets; prolonged general fetal movements precluded processing of the remaining three data sets. The proposed method shows promise as a motion-tolerant framework to enable further detail in MRI studies of the fetal heart and great vessels. Processing data in image-space allowed for spatial and temporal operations to be applied to the fetal heart in isolation, separate from extraneous changes elsewhere in the field of view. Magn Reson Med 79:327-338, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

  8. Pattern-based approach to fetal congenital cardiovascular anomalies using the transverse aortic arch view on prenatal cardiac MRI

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Su-Zhen; Zhu, Ming [Shanghai Jiaotong University School of Medicine, Department of Radiology, Shanghai Children' s Medical Center, Shanghai (China)

    2015-05-01

    Fetal echocardiography is the imaging modality of choice for prenatal diagnosis of congenital cardiovascular anomalies. However, echocardiography has limitations. Fetal cardiac magnetic resonance imaging (MRI) has the potential to complement US in detecting congenital cardiovascular anomalies. This article draws on our experience; it describes the transverse aortic arch view on fetal cardiac MRI and important clues on an abnormal transverse view at the level of the aortic arch to the diagnosis of fetal congenital cardiovascular anomalies. (orig.)

  9. Pattern-based approach to fetal congenital cardiovascular anomalies using the transverse aortic arch view on prenatal cardiac MRI

    International Nuclear Information System (INIS)

    Dong, Su-Zhen; Zhu, Ming

    2015-01-01

    Fetal echocardiography is the imaging modality of choice for prenatal diagnosis of congenital cardiovascular anomalies. However, echocardiography has limitations. Fetal cardiac magnetic resonance imaging (MRI) has the potential to complement US in detecting congenital cardiovascular anomalies. This article draws on our experience; it describes the transverse aortic arch view on fetal cardiac MRI and important clues on an abnormal transverse view at the level of the aortic arch to the diagnosis of fetal congenital cardiovascular anomalies. (orig.)

  10. Integrating atlas and graph cut methods for right ventricle blood-pool segmentation from cardiac cine MRI

    Science.gov (United States)

    Dangi, Shusil; Linte, Cristian A.

    2017-03-01

    Segmentation of right ventricle from cardiac MRI images can be used to build pre-operative anatomical heart models to precisely identify regions of interest during minimally invasive therapy. Furthermore, many functional parameters of right heart such as right ventricular volume, ejection fraction, myocardial mass and thickness can also be assessed from the segmented images. To obtain an accurate and computationally efficient segmentation of right ventricle from cardiac cine MRI, we propose a segmentation algorithm formulated as an energy minimization problem in a graph. Shape prior obtained by propagating label from an average atlas using affine registration is incorporated into the graph framework to overcome problems in ill-defined image regions. The optimal segmentation corresponding to the labeling with minimum energy configuration of the graph is obtained via graph-cuts and is iteratively refined to produce the final right ventricle blood pool segmentation. We quantitatively compare the segmentation results obtained from our algorithm to the provided gold-standard expert manual segmentation for 16 cine-MRI datasets available through the MICCAI 2012 Cardiac MR Right Ventricle Segmentation Challenge according to several similarity metrics, including Dice coefficient, Jaccard coefficient, Hausdorff distance, and Mean absolute distance error.

  11. Automated segmentation and reconstruction of patient-specific cardiac anatomy and pathology from in vivo MRI

    International Nuclear Information System (INIS)

    Ringenberg, Jordan; Deo, Makarand; Devabhaktuni, Vijay; Filgueiras-Rama, David; Pizarro, Gonzalo; Ibañez, Borja; Berenfeld, Omer; Boyers, Pamela; Gold, Jeffrey

    2012-01-01

    This paper presents an automated method to segment left ventricle (LV) tissues from functional and delayed-enhancement (DE) cardiac magnetic resonance imaging (MRI) scans using a sequential multi-step approach. First, a region of interest (ROI) is computed to create a subvolume around the LV using morphological operations and image arithmetic. From the subvolume, the myocardial contours are automatically delineated using difference of Gaussians (DoG) filters and GSV snakes. These contours are used as a mask to identify pathological tissues, such as fibrosis or scar, within the DE-MRI. The presented automated technique is able to accurately delineate the myocardium and identify the pathological tissue in patient sets. The results were validated by two expert cardiologists, and in one set the automated results are quantitatively and qualitatively compared with expert manual delineation. Furthermore, the method is patient-specific, performed on an entire patient MRI series. Thus, in addition to providing a quick analysis of individual MRI scans, the fully automated segmentation method is used for effectively tagging regions in order to reconstruct computerized patient-specific 3D cardiac models. These models can then be used in electrophysiological studies and surgical strategy planning. (paper)

  12. Value of cardiac MRI for evaluation of chronic Chagas disease cardiomyopathy

    International Nuclear Information System (INIS)

    Lee-Felker, S.A.; Thomas, M.; Felker, E.R.; Traina, M.; Salih, M.; Hernandez, S.; Bradfield, J.; Lee, M.; Meymandi, S.

    2016-01-01

    Aim: To determine whether cardiac magnetic resonance imaging (cMRI) is more sensitive than electrocardiogram (ECG) and echocardiogram (ECHO) for detecting myocardial involvement in a Latin American migrant population with untreated Chagas disease (CD) in the United States. Materials and methods: All untreated CD patients with ECG and ECHO examinations who underwent cMRI at Olive View-UCLA Medical Center from September 2010 to December 2013 (n=81) were analysed in three groups: Group 1, normal ECG and ECHO examinations (n=50); Group 2, abnormal ECG and normal ECHO examinations (n=10); and Group 3, abnormal ECHO examination (n=21). Frequencies of ECG, ECHO, and cMRI findings were compared across groups. Results: Seventy percent (57/81) of the study population was female, with a mean age of 47 years (range, 17–77 years). Twenty-six percent (21/81) had delayed myocardial enhancement (DME), which was most commonly inferolateral in location (27%, 32/117 segments) and transmural in pattern (56%, 65/117 segments). Eight percent (4/50), 30% (3/10), and 67% (14/21) of Groups 1–3, respectively, had DME. Of these individuals with DME, 50% (2/4), 67% (2/3), and 100% (14/14) of Groups 1–3, respectively, also had wall motion abnormality (WMA) on cMRI. In addition to the highest percentages of DME and WMA, Group 3 also had significantly higher mean myocardial mass (p<0.01), mean left ventricular end-diastolic (p<0.01) and end-systolic volumes (p<0.0005), and significantly lower mean left ventricular ejection fraction (p<0.001). Conclusion: cMRI may detect myocardial involvement in untreated CD that is otherwise unrecognised on ECG and ECHO. - Highlights: • Chagas disease (CD) is becoming more common outside Latin America, especially in the United States. • CD is often asymptomatic, with undetected myocardial involvement. • Cardiac magnetic resonance imaging may identify myocardial involvement prior to electrocardiogram and echocardiogram changes. • Early detection

  13. MO-A-BRD-08: Radiosurgery Beyond Cancer: Real-Time Target Localization and Treatment Planning for Cardiac Radiosurgery Under MRI Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Ipsen, S [University of Luebeck, Luebeck, SH (Germany); University of Sydney, Camperdown (Australia); Blanck, O [CyberKnife Zentrum Norddeutschland, Guestrow, MV (Germany); Oborn, B [Illawarra Cancer Care Centre, Wollongong, NSW (Australia); Bode, F [Medical Clinic II, Section for Electrophysiology, UKSH, Luebeck, SH (Germany); Liney, G [Ingham Institute for Applied Medical Research, Liverpool, NSW (United Kingdom); Keall, P [University of Sydney, Camperdown (Australia)

    2014-06-15

    Purpose: Atrial fibrillation (AF) is the most common cardiac arrhythmia, affecting >2.5M Americans and >4.5M Europeans. AF is usually treated with minimally-invasive, time consuming catheter ablation techniques. Radiosurgery of the pulmonary veins (PV) has been proposed for AF treatment, however is challenging due to the complex respiratory and cardiac motion patterns. We hypothesize that an MRI-linac could solve the difficult real-time targeting and adaptation problem. In this study we quantified target motion ranges on cardiac MRI and analyzed the dosimetric benefits of margin reduction assuming real-time MRI tracking was applied. Methods: For the motion study, four human subjects underwent real-time cardiac MRI under free breathing. The target motion on coronal and axial cine planes was analyzed using a template matching algorithm. For the planning study, an ablation line at each PV antrum was defined as target on an AF patient scheduled for catheter ablation. Various safety margins ranging from 0mm (perfect tracking) to 8mm (untracked motion) were added to the target defining the PTV. 30Gy single fraction IMRT plans were then generated. Finally, the influence of a 1T magnetic field on treatment beam delivery was calculated using the Geant4 Monte Carlo algorithm to simulate the dosimetric impact of MRI guidance. Results: The motion study showed the mean respiratory motion of the target area on MRI was 8.4mm (SI), 1.7mm (AP) and 0.3mm (LR). Cardiac motion was small (<2mm). The planning study showed that with increasing safety margins to encompass untracked motion, dose tolerances for OARs such as the esophagus and airways were exceeded by >100%. The magnetic field had little impact on the dose distribution. Conclusion: Our results indicate that real-time MRI tracking of the PVs seems feasible. Accurate image guidance for high-dose AF radiosurgery is essential since safety margins covering untracked target motion will result in unacceptable treatment plans.

  14. Interpolation of vector fields from human cardiac DT-MRI

    International Nuclear Information System (INIS)

    Yang, F; Zhu, Y M; Rapacchi, S; Robini, M; Croisille, P; Luo, J H

    2011-01-01

    There has recently been increased interest in developing tensor data processing methods for the new medical imaging modality referred to as diffusion tensor magnetic resonance imaging (DT-MRI). This paper proposes a method for interpolating the primary vector fields from human cardiac DT-MRI, with the particularity of achieving interpolation and denoising simultaneously. The method consists of localizing the noise-corrupted vectors using the local statistical properties of vector fields, removing the noise-corrupted vectors and reconstructing them by using the thin plate spline (TPS) model, and finally applying global TPS interpolation to increase the resolution in the spatial domain. Experiments on 17 human hearts show that the proposed method allows us to obtain higher resolution while reducing noise, preserving details and improving direction coherence (DC) of vector fields as well as fiber tracking. Moreover, the proposed method perfectly reconstructs azimuth and elevation angle maps.

  15. In vivo T2* weighted MRI visualizes cardiac lesions in murine models of acute and chronic viral myocarditis.

    Directory of Open Access Journals (Sweden)

    Xavier Helluy

    Full Text Available Acute and chronic forms of myocarditis are mainly induced by virus infections. As a consequence of myocardial damage and inflammation dilated cardiomyopathy and chronic heart failure may develop. The gold standard for the diagnosis of myocarditis is endomyocardial biopsies which are required to determine the etiopathogenesis of cardiac inflammatory processes. However, new non-invasive MRI techniques hold great potential in visualizing cardiac non-ischemic inflammatory lesions at high spatial resolution, which could improve the investigation of the pathophysiology of viral myocarditis.Here we present the discovery of a novel endogenous T2* MRI contrast of myocardial lesions in murine models of acute and chronic CVB3 myocarditis. The evaluation of infected hearts ex vivo and in vivo by 3D T2w and T2*w MRI allowed direct localization of virus-induced myocardial lesions without any MRI tracer or contrast agent. T2*w weighted MRI is able to detect both small cardiac lesions of acute myocarditis and larger necrotic areas at later stages of chronic myocarditis, which was confirmed by spatial correlation of MRI hypointensity in myocardium with myocardial lesions histologically. Additional in vivo and ex vivo MRI analysis proved that the contrast mechanism was due to a strong paramagnetic tissue alteration in the vicinity of myocardial lesions, effectively pointing towards iron deposits as the primary contributor of contrast. The evaluation of the biological origin of the MR contrast by specific histological staining and transmission electron microscopy revealed that impaired iron metabolism primarily in mitochondria caused iron deposits within necrotic myocytes, which induces strong magnetic susceptibility in myocardial lesions and results in strong T2* contrast.This T2*w MRI technique provides a fast and sensitive diagnostic tool to determine the patterns and the severity of acute and chronic enteroviral myocarditis and the precise localization of

  16. Unsupervised motion-compensation of multi-slice cardiac perfusion MRI

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Ólafsdóttir, Hildur; Larsson, Henrik B. W.

    2005-01-01

    This paper presents a novel method for registration of single and multi-slice cardiac perfusion MRI. Utilising computer intensive analyses of variance and clustering in an annotated training set off-line, the presented method is capable of providing registration without any manual interaction...... in less than a second per frame. Changes in image intensity during the bolus passage are modelled by a slice-coupled active appearance model, which is augmented with a cluster analysis of the training set. Landmark correspondences are optimised using the MDL framework due to Davies et al. Image search...

  17. MRI in ischemic heart disease

    International Nuclear Information System (INIS)

    Hazirolan, T.

    2012-01-01

    Full text: The role of magnetic resonance imaging in the evaluation of ischemic heart disease has increased over the last years. Cardiac MRI is the only imaging modality that provides 'one stop shop' assessment. Information about ventricular function, myocardial ischemia and myocardial viability can be obtained in a single cardiac MRI session. Additionally, Cardiac MRI has become a gold standard method in evaluation of myocardial viability and in assessment of ventricular mass and function. As a result, cardiac MRI enable radiologist to comprehensively assess ischemic heart disease. The aim of this presentation is to provide the reader a state-of-the art on how the newest cardiac MRI techniques can be used to study ischemic heart disease patients.

  18. Cardiac Imaging Using Clinical 1.5 T MRI Scanners in a Murine Ischemia/Reperfusion Model

    Directory of Open Access Journals (Sweden)

    Jakob G. J. Voelkl

    2011-01-01

    Full Text Available To perform cardiac imaging in mice without having to invest in expensive dedicated equipment, we adapted a clinical 1.5 Tesla (T magnetic resonance imaging (MRI scanner for use in a murine ischemia/reperfusion model. Phase-sensitive inversion recovery (PSIR sequence facilitated the determination of infarct sizes in vivo by late gadolinium enhancement. Results were compared to histological infarct areas in mice after ischemia/reperfusion procedure with a good correlation (=0.807, <.001. In addition, fractional area change (FAC was assessed with single slice cine MRI and was matched to infarct size (=−0.837 and fractional shortening (FS measured with echocardiography (=0.860; both <.001. Here, we demonstrate the use of clinical 1.5 MRI scanners as a feasible method for basic phenotyping in mice. These widely available scanners are capable of investigating in vivo infarct dimensions as well as assessment of cardiac functional parameters in mice with reasonable throughput.

  19. Self-gated fetal cardiac MRI with tiny golden angle iGRASP: A feasibility study.

    Science.gov (United States)

    Haris, Kostas; Hedström, Erik; Bidhult, Sebastian; Testud, Frederik; Maglaveras, Nicos; Heiberg, Einar; Hansson, Stefan R; Arheden, Håkan; Aletras, Anthony H

    2017-07-01

    To develop and assess a technique for self-gated fetal cardiac cine magnetic resonance imaging (MRI) using tiny golden angle radial sampling combined with iGRASP (iterative Golden-angle RAdial Sparse Parallel) for accelerated acquisition based on parallel imaging and compressed sensing. Fetal cardiac data were acquired from five volunteers in gestational week 29-37 at 1.5T using tiny golden angles for eddy currents reduction. The acquired multicoil radial projections were input to a principal component analysis-based compression stage. The cardiac self-gating (CSG) signal for cardiac gating was extracted from the acquired radial projections and the iGRASP reconstruction procedure was applied. In all acquisitions, a total of 4000 radial spokes were acquired within a breath-hold of less than 15 seconds using a balanced steady-state free precession pulse sequence. The images were qualitatively compared by two independent observers (on a scale of 1-4) to a single midventricular cine image from metric optimized gating (MOG) and real-time acquisitions. For iGRASP and MOG images, good overall image quality (2.8 ± 0.4 and 2.6 ± 1.3, respectively, for observer 1; 3.6 ± 0.5 and 3.4 ± 0.9, respectively, for observer 2) and cardiac diagnostic quality (3.8 ± 0.4 and 3.4 ± 0.9, respectively, for observer 1; 3.6 ± 0.5 and 3.6 ± 0.9, respectively, for observer 2) were obtained, with visualized myocardial thickening over the cardiac cycle and well-defined myocardial borders to ventricular lumen and liver/lung tissue. For iGRASP, MOG, and real time, left ventricular lumen diameter (14.1 ± 2.2 mm, 14.2 ± 1.9 mm, 14.7 ± 1.1 mm, respectively) and wall thickness (2.7 ± 0.3 mm, 2.6 ± 0.3 mm, 3.0 ± 0.4, respectively) showed agreement and no statistically significant difference was found (all P > 0.05). Images with iGRASP tended to have higher overall image quality scores compared with MOG and particularly

  20. Assessment of myocardial infarction with delayed-enhancement MRI in coronary artery disease: a correlative study with cardiac events

    International Nuclear Information System (INIS)

    Zhao Xinxiang; Yang Chao; Yang Dakuan; Yuan Shuguang; Yang Xinhuan; Wang Zhong

    2011-01-01

    Objective: To investigate the correlation between recent cardiac events and the score of myocardial infarction by delayed-enhancement MRI (DE-MRI). Methods: DE-MRI was performed in 40 subjects with coronary artery disease. The score of myocardial infarction by DE-MRI, the ejection fraction (EF) by echocardiography, recent cardiac events (the number of weekly nitroglycerin, the number of weekly angina episodes and the onset number of heart failure in the last year), 6-minute walking distance, as well as the Seattle angina questionnaire (SAQ) score were assessed. The Spearman correlation test and Kruskal-Wallis test, Mann-Whitney test were used for the statistics. Results: There were negative correlation between the myocardial infarction score by DE-MRI (median 12, inter-quartile range: 6.0-19.8) and the 6-minute walking distance (378.93±100.53), SAQ score (74.55±11.40) (r was 0.66 and 0.54, P< 0.05). The myocardial infarction score by DE-MRI was strongly correlated with the number of weekly nitroglycerin (median 1; inter-quartile range: 0-2.8), the number of weekly angina episodes (median 3, inter-quartile range: 1-6.5) and the onset number of heart failure in the last year (median 0, inter-quartile range: 0-2) (r was 0.87, 0.85 and 0.89, P<0.05). EF [(49.2±13.72)%] was negative correlation with the number of weekly nitroglycerin, the number of weekly angina episodes and the onset number of heart failure in the last year (r were 0.67, 0.73 and 0.73, P<0.05). Conclusion: DE-MRI can be used for evaluation and prediction of future cardiac events. (authors)

  1. Hybrid cardiac imaging using PET/MRI: a joint position statement by the European Society of Cardiovascular Radiology (ESCR) and the European Association of Nuclear Medicine (EANM).

    Science.gov (United States)

    Nensa, Felix; Bamberg, Fabian; Rischpler, Christoph; Menezes, Leon; Poeppel, Thorsten D; la Fougère, Christian; Beitzke, Dietrich; Rasul, Sazan; Loewe, Christian; Nikolaou, Konstantin; Bucerius, Jan; Kjaer, Andreas; Gutberlet, Matthias; Prakken, Niek H; Vliegenthart, Rozemarijn; Slart, Riemer H J A; Nekolla, Stephan G; Lassen, Martin L; Pichler, Bernd J; Schlosser, Thomas; Jacquier, Alexis; Quick, Harald H; Schäfers, Michael; Hacker, Marcus

    2018-05-02

    Positron emission tomography (PET) and magnetic resonance imaging (MRI) have both been used for decades in cardiovascular imaging. Since 2010, hybrid PET/MRI using sequential and integrated scanner platforms has been available, with hybrid cardiac PET/MR imaging protocols increasingly incorporated into clinical workflows. Given the range of complementary information provided by each method, the use of hybrid PET/MRI may be justified and beneficial in particular clinical settings for the evaluation of different disease entities. In the present joint position statement, we critically review the role and value of integrated PET/MRI in cardiovascular imaging, provide a technical overview of cardiac PET/MRI and practical advice related to the cardiac PET/MRI workflow, identify cardiovascular applications that can potentially benefit from hybrid PET/MRI, and describe the needs for future development and research. In order to encourage its wide dissemination, this article is freely accessible on the European Radiology and European Journal of Hybrid Imaging web sites. • Studies and case-reports indicate that PET/MRI is a feasible and robust technology. • Promising fields of application include a variety of cardiac conditions. • Larger studies are required to demonstrate its incremental and cost-effective value. • The translation of novel radiopharmaceuticals and MR-sequences will provide exciting new opportunities.

  2. Left ventricle segmentation in cardiac MRI images using fully convolutional neural networks

    Science.gov (United States)

    Vázquez Romaguera, Liset; Costa, Marly Guimarães Fernandes; Romero, Francisco Perdigón; Costa Filho, Cicero Ferreira Fernandes

    2017-03-01

    According to the World Health Organization, cardiovascular diseases are the leading cause of death worldwide, accounting for 17.3 million deaths per year, a number that is expected to grow to more than 23.6 million by 2030. Most cardiac pathologies involve the left ventricle; therefore, estimation of several functional parameters from a previous segmentation of this structure can be helpful in diagnosis. Manual delineation is a time consuming and tedious task that is also prone to high intra and inter-observer variability. Thus, there exists a need for automated cardiac segmentation method to help facilitate the diagnosis of cardiovascular diseases. In this work we propose a deep fully convolutional neural network architecture to address this issue and assess its performance. The model was trained end to end in a supervised learning stage from whole cardiac MRI images input and ground truth to make a per pixel classification. For its design, development and experimentation was used Caffe deep learning framework over an NVidia Quadro K4200 Graphics Processing Unit. The net architecture is: Conv64-ReLU (2x) - MaxPooling - Conv128-ReLU (2x) - MaxPooling - Conv256-ReLU (2x) - MaxPooling - Conv512-ReLu-Dropout (2x) - Conv2-ReLU - Deconv - Crop - Softmax. Training and testing processes were carried out using 5-fold cross validation with short axis cardiac magnetic resonance images from Sunnybrook Database. We obtained a Dice score of 0.92 and 0.90, Hausdorff distance of 4.48 and 5.43, Jaccard index of 0.97 and 0.97, sensitivity of 0.92 and 0.90 and specificity of 0.99 and 0.99, overall mean values with SGD and RMSProp, respectively.

  3. Characterization of respiratory and cardiac motion from electro-anatomical mapping data for improved fusion of MRI to left ventricular electrograms.

    Directory of Open Access Journals (Sweden)

    Sébastien Roujol

    Full Text Available Accurate fusion of late gadolinium enhancement magnetic resonance imaging (MRI and electro-anatomical voltage mapping (EAM is required to evaluate the potential of MRI to identify the substrate of ventricular tachycardia. However, both datasets are not acquired at the same cardiac phase and EAM data is corrupted with respiratory motion limiting the accuracy of current rigid fusion techniques. Knowledge of cardiac and respiratory motion during EAM is thus required to enhance the fusion process. In this study, we propose a novel approach to characterize both cardiac and respiratory motion from EAM data using the temporal evolution of the 3D catheter location recorded from clinical EAM systems. Cardiac and respiratory motion components are extracted from the recorded catheter location using multi-band filters. Filters are calibrated for each EAM point using estimates of heart rate and respiratory rate. The method was first evaluated in numerical simulations using 3D models of cardiac and respiratory motions of the heart generated from real time MRI data acquired in 5 healthy subjects. An accuracy of 0.6-0.7 mm was found for both cardiac and respiratory motion estimates in numerical simulations. Cardiac and respiratory motions were then characterized in 27 patients who underwent LV mapping for treatment of ventricular tachycardia. Mean maximum amplitude of cardiac and respiratory motion was 10.2±2.7 mm (min = 5.5, max = 16.9 and 8.8±2.3 mm (min = 4.3, max = 14.8, respectively. 3D Cardiac and respiratory motions could be estimated from the recorded catheter location and the method does not rely on additional imaging modality such as X-ray fluoroscopy and can be used in conventional electrophysiology laboratory setting.

  4. Churg-Strauss Syndrome with Cardiac Involvement: A Case Report with CT and MRI Findings

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Seong Joo; Cho, Young Jun; Kim, Keum; Hwang, Cheol Mok; Kim, Dae Ho [Dept. of Radiology, Konyang University College of Medicine, Daegu (Korea, Republic of); Choi, Eu Gene [Dept. of Internal Medicine, Konyang University College of Medicine, Daegu (Korea, Republic of)

    2012-02-15

    This is a case report of Churg-Strauss Syndrome (CSS) associated with cardiac involvement which is demonstrated in chest CT and cardiac MRI (CMR) without specific cardiac symptoms. A 32-year-old woman had a 3-year history of bronchial asthma, chronic sinusitis, and otitis media. The patient had various typical findings of CSS. The patient had no specific cardiac symptoms or signs such as chest pain, palpitations, syncope, or murmur, but she had diffuse low attenuation lesions in the inner wall of the left ventricle (LV) in contrast-enhanced CT. This corresponded to the area of subendocardial hyperenhancement in delayed contrast-enhanced CMR images. She was treated with steroids for 2 months. Follow-up delayed contrast-enhanced CMR of the LV showed a decrease in the size of the subendocardial enhancement area, and she had no symptoms. Therefore, the radiologist and clinician both should pay careful attention to observe possible cardiac involvement in case of CSS.

  5. Churg-Strauss Syndrome with Cardiac Involvement: A Case Report with CT and MRI Findings

    International Nuclear Information System (INIS)

    Lim, Seong Joo; Cho, Young Jun; Kim, Keum; Hwang, Cheol Mok; Kim, Dae Ho; Choi, Eu Gene

    2012-01-01

    This is a case report of Churg-Strauss Syndrome (CSS) associated with cardiac involvement which is demonstrated in chest CT and cardiac MRI (CMR) without specific cardiac symptoms. A 32-year-old woman had a 3-year history of bronchial asthma, chronic sinusitis, and otitis media. The patient had various typical findings of CSS. The patient had no specific cardiac symptoms or signs such as chest pain, palpitations, syncope, or murmur, but she had diffuse low attenuation lesions in the inner wall of the left ventricle (LV) in contrast-enhanced CT. This corresponded to the area of subendocardial hyperenhancement in delayed contrast-enhanced CMR images. She was treated with steroids for 2 months. Follow-up delayed contrast-enhanced CMR of the LV showed a decrease in the size of the subendocardial enhancement area, and she had no symptoms. Therefore, the radiologist and clinician both should pay careful attention to observe possible cardiac involvement in case of CSS.

  6. On the Averaging of Cardiac Diffusion Tensor MRI Data: The Effect of Distance Function Selection

    Science.gov (United States)

    Giannakidis, Archontis; Melkus, Gerd; Yang, Guang; Gullberg, Grant T.

    2016-01-01

    Diffusion tensor magnetic resonance imaging (DT-MRI) allows a unique insight into the microstructure of highly-directional tissues. The selection of the most proper distance function for the space of diffusion tensors is crucial in enhancing the clinical application of this imaging modality. Both linear and nonlinear metrics have been proposed in the literature over the years. The debate on the most appropriate DT-MRI distance function is still ongoing. In this paper, we presented a framework to compare the Euclidean, affine-invariant Riemannian and log-Euclidean metrics using actual high-resolution DT-MRI rat heart data. We employed temporal averaging at the diffusion tensor level of three consecutive and identically-acquired DT-MRI datasets from each of five rat hearts as a means to rectify the background noise-induced loss of myocyte directional regularity. This procedure is applied here for the first time in the context of tensor distance function selection. When compared with previous studies that used a different concrete application to juxtapose the various DT-MRI distance functions, this work is unique in that it combined the following: (i) Metrics were judged by quantitative –rather than qualitative– criteria, (ii) the comparison tools were non-biased, (iii) a longitudinal comparison operation was used on a same-voxel basis. The statistical analyses of the comparison showed that the three DT-MRI distance functions tend to provide equivalent results. Hence, we came to the conclusion that the tensor manifold for cardiac DT-MRI studies is a curved space of almost zero curvature. The signal to noise ratio dependence of the operations was investigated through simulations. Finally, the “swelling effect” occurrence following Euclidean averaging was found to be too unimportant to be worth consideration. PMID:27754986

  7. On the averaging of cardiac diffusion tensor MRI data: the effect of distance function selection

    Science.gov (United States)

    Giannakidis, Archontis; Melkus, Gerd; Yang, Guang; Gullberg, Grant T.

    2016-11-01

    Diffusion tensor magnetic resonance imaging (DT-MRI) allows a unique insight into the microstructure of highly-directional tissues. The selection of the most proper distance function for the space of diffusion tensors is crucial in enhancing the clinical application of this imaging modality. Both linear and nonlinear metrics have been proposed in the literature over the years. The debate on the most appropriate DT-MRI distance function is still ongoing. In this paper, we presented a framework to compare the Euclidean, affine-invariant Riemannian and log-Euclidean metrics using actual high-resolution DT-MRI rat heart data. We employed temporal averaging at the diffusion tensor level of three consecutive and identically-acquired DT-MRI datasets from each of five rat hearts as a means to rectify the background noise-induced loss of myocyte directional regularity. This procedure is applied here for the first time in the context of tensor distance function selection. When compared with previous studies that used a different concrete application to juxtapose the various DT-MRI distance functions, this work is unique in that it combined the following: (i) metrics were judged by quantitative—rather than qualitative—criteria, (ii) the comparison tools were non-biased, (iii) a longitudinal comparison operation was used on a same-voxel basis. The statistical analyses of the comparison showed that the three DT-MRI distance functions tend to provide equivalent results. Hence, we came to the conclusion that the tensor manifold for cardiac DT-MRI studies is a curved space of almost zero curvature. The signal to noise ratio dependence of the operations was investigated through simulations. Finally, the ‘swelling effect’ occurrence following Euclidean averaging was found to be too unimportant to be worth consideration.

  8. In vivo T2* weighted MRI visualizes cardiac lesions in murine models of acute and chronic viral myocarditis

    Science.gov (United States)

    Helluy, Xavier; Sauter, Martina; Ye, Yu-Xiang; Lykowsky, Gunthard; Kreutner, Jakob; Yilmaz, Ali; Jahns, Roland; Boivin, Valerie; Kandolf, Reinhard; Jakob, Peter M.; Hiller, Karl-Heinz; Klingel, Karin

    2017-01-01

    Objective Acute and chronic forms of myocarditis are mainly induced by virus infections. As a consequence of myocardial damage and inflammation dilated cardiomyopathy and chronic heart failure may develop. The gold standard for the diagnosis of myocarditis is endomyocardial biopsies which are required to determine the etiopathogenesis of cardiac inflammatory processes. However, new non-invasive MRI techniques hold great potential in visualizing cardiac non-ischemic inflammatory lesions at high spatial resolution, which could improve the investigation of the pathophysiology of viral myocarditis. Results Here we present the discovery of a novel endogenous T2* MRI contrast of myocardial lesions in murine models of acute and chronic CVB3 myocarditis. The evaluation of infected hearts ex vivo and in vivo by 3D T2w and T2*w MRI allowed direct localization of virus-induced myocardial lesions without any MRI tracer or contrast agent. T2*w weighted MRI is able to detect both small cardiac lesions of acute myocarditis and larger necrotic areas at later stages of chronic myocarditis, which was confirmed by spatial correlation of MRI hypointensity in myocardium with myocardial lesions histologically. Additional in vivo and ex vivo MRI analysis proved that the contrast mechanism was due to a strong paramagnetic tissue alteration in the vicinity of myocardial lesions, effectively pointing towards iron deposits as the primary contributor of contrast. The evaluation of the biological origin of the MR contrast by specific histological staining and transmission electron microscopy revealed that impaired iron metabolism primarily in mitochondria caused iron deposits within necrotic myocytes, which induces strong magnetic susceptibility in myocardial lesions and results in strong T2* contrast. Conclusion This T2*w MRI technique provides a fast and sensitive diagnostic tool to determine the patterns and the severity of acute and chronic enteroviral myocarditis and the precise

  9. Cardiac phenotyping in ex vivo murine embryos using microMRI.

    Science.gov (United States)

    Cleary, Jon O; Price, Anthony N; Thomas, David L; Scambler, Peter J; Kyriakopoulou, Vanessa; McCue, Karen; Schneider, Jürgen E; Ordidge, Roger J; Lythgoe, Mark F

    2009-10-01

    Microscopic MRI (microMRI) is an emerging technique for high-throughput phenotyping of transgenic mouse embryos, and is capable of visualising abnormalities in cardiac development. To identify cardiac defects in embryos, we have optimised embryo preparation and MR acquisition parameters to maximise image quality and assess the phenotypic changes in chromodomain helicase DNA-binding protein 7 (Chd7) transgenic mice. microMRI methods rely on tissue penetration with a gadolinium chelate contrast agent to reduce tissue T(1), thus improving signal-to-noise ratio (SNR) in rapid gradient echo sequences. We investigated 15.5 days post coitum (dpc) wild-type CD-1 embryos fixed in gadolinium-diethylene triamine pentaacetic acid (Gd-DTPA) solutions for either 3 days (2 and 4 mM) or 2 weeks (2, 4, 8 and 16 mM). To assess penetration of the contrast agent into heart tissue and enable image contrast simulations, T(1) and T(*) (2) were measured in heart and background agarose. Compared to 3-day, 2-week fixation showed reduced mean T(1) in the heart at both 2 and 4 mM concentrations (p < 0.0001), resulting in calculated signal gains of 23% (2 mM) and 29% (4 mM). Using T(1) and T(*) (2) values from 2-week concentrations, computer simulation of heart and background signal, and ex vivo 3D gradient echo imaging, we demonstrated that 2-week fixed embryos in 8 mM Gd-DTPA in combination with optimised parameters (TE/TR/alpha/number of averages: 9 ms/20 ms/60 degrees /7) produced the largest SNR in the heart (23.2 +/- 1.0) and heart chamber contrast-to-noise ratio (CNR) (27.1 +/- 1.6). These optimised parameters were then applied to an MRI screen of embryos heterozygous for the gene Chd7, implicated in coloboma of the eye, heart defects, atresia of the choanae, retardation of growth, genital/urinary abnormalities, ear abnormalities and deafness (CHARGE) syndrome (a condition partly characterised by cardiovascular birth defects in humans). A ventricular septal defect was readily identified

  10. The Correlation of Cardiac and Hepatic Hemosiderosis as Measured by T2*MRI Technique with Ferritin Levels and Hemochromatosis Gene Mutations in Iranian Patients with Beta Thalassemia Major

    Directory of Open Access Journals (Sweden)

    Mohammad Soleiman Soltanpour

    2018-01-01

    Full Text Available Objectives: Organ-specific hemosiderosis and iron overload complications are more serious and more frequent in some patients with beta thalassemia major (BTM compared with others. We investigated whether coinheritance of HFE H63D or C282Y gene mutations in patients with BTM contributes to the phenotypic variation of iron overload complications and assessed the correlation of cardiac and hepatic hemosiderosis with plasma ferritin levels. Methods: We studied 60 patients with BTM with a mean age of 17.5±9.1 years from the Northwest of Iran. HFE gene mutations were analyzed using the polymerase chain reaction-restriction fragment length polymorphism method. Cardiac and hepatic hemosiderosis was assessed using T2*magnetic resonance imaging (MRI. Ferritin levels were measured using the enzyme immunoassay method. Results: Ferritin levels showed a strong inverse correlation with hepatic T2*MRI values (r = -0.631, p = 0.001 but a poor correlation with cardiac T2*MRI values (r = -0.297, p = 0.044. The correlation between cardiac T2*MRI values and hepatic T2*MRI values was poor and insignificant (r = 0.287, p = 0.058. Genotype and allele distribution of HFE H63D and C282Y mutation did not differ significantly between patients with and without hepatic or cardiac hemosiderosis (p > 0.050. However, carriers of HFE 63D allele had significantly higher ferritin levels compared with non-carriers (1 903±993 vs. 992±683, p < 0.001. Conclusions: Cardiac T2*MRI values showed a poor correlation with hepatic T2*MRI values and ferritin levels. Accurate assessment of cardiac iron overload in patients with BTM can only be done using the T2*MRI technique. Additionally, HFE H63D is a significant determinant factor for elevated ferritin levels in BTM patients.

  11. Accelerated dynamic cardiac MRI exploiting sparse-Kalman-smoother self-calibration and reconstruction (k  −  t SPARKS)

    International Nuclear Information System (INIS)

    Park, Suhyung; Park, Jaeseok

    2015-01-01

    Accelerated dynamic MRI, which exploits spatiotemporal redundancies in k  −  t space and coil dimension, has been widely used to reduce the number of signal encoding and thus increase imaging efficiency with minimal loss of image quality. Nonetheless, particularly in cardiac MRI it still suffers from artifacts and amplified noise in the presence of time-drifting coil sensitivity due to relative motion between coil and subject (e.g. free breathing). Furthermore, a substantial number of additional calibrating signals is to be acquired to warrant accurate calibration of coil sensitivity. In this work, we propose a novel, accelerated dynamic cardiac MRI with sparse-Kalman-smoother self-calibration and reconstruction (k  −  t SPARKS), which is robust to time-varying coil sensitivity even with a small number of calibrating signals. The proposed k  −  t SPARKS incorporates Kalman-smoother self-calibration in k  −  t space and sparse signal recovery in x  −   f space into a single optimization problem, leading to iterative, joint estimation of time-varying convolution kernels and missing signals in k  −  t space. In the Kalman-smoother calibration, motion-induced uncertainties over the entire time frames were included in modeling state transition while a coil-dependent noise statistic in describing measurement process. The sparse signal recovery iteratively alternates with the self-calibration to tackle the ill-conditioning problem potentially resulting from insufficient calibrating signals. Simulations and experiments were performed using both the proposed and conventional methods for comparison, revealing that the proposed k  −  t SPARKS yields higher signal-to-error ratio and superior temporal fidelity in both breath-hold and free-breathing cardiac applications over all reduction factors. (paper)

  12. Cardiac carcinoid: tricuspid delayed hyperenhancement on cardiac 64-slice multidetector CT and magnetic resonance imaging.

    LENUS (Irish Health Repository)

    Martos, R

    2012-02-01

    INTRODUCTION: Carcinoid heart disease is a rare condition in adults. Its diagnosis can be easily missed in a patient presenting to a primary care setting. We revised the advantages of using coronary multidetector computed tomography (MDCT) and cardiac magnetic resonance imaging (MRI) in diagnosing this condition. MATERIALS AND METHODS: We studied a 65-year-old patient with carcinoid heart disease and right heart failure using transthoracic Doppler-echocardiogram, cardiac MDCT and MRI. Cardiac echocardiogram revealed marked thickening and retraction of the tricuspid leaflets with dilated right atrium and ventricle. Cardiac MDCT and MRI demonstrated fixation and retraction of the tricuspid leaflets with delayed contrast hyperenhancement of the tricuspid annulus. CONCLUSION: This case demonstrates fascinating imaging findings of cardiac carcinoid disease and highlights the increasing utility of contrast-enhanced MRI and cardiac MDCT in the diagnosis of this interesting condition.

  13. A case of catastrophic antiphospholipid syndrome: first report with advanced cardiac imaging using MRI.

    Science.gov (United States)

    Rosenbaum, A N; Anavekar, N S; Ernste, F C; Mankad, S V; Le, R J; Manocha, K K; Barsness, G W

    2015-10-01

    This present case pertains to a 48-year-old woman with a history of antiphospholipid syndrome, who presented with progressive fatigue, generalized weakness, and orthopnea acutely. She had a prior diagnosis of antiphospholipid syndrome with recurrent deep vein thromboses (DVTs) and repeated demonstration of lupus anticoagulants. She presented in cardiogenic shock with markedly elevated troponin and global myocardial dysfunction on echocardiography, and cardiac catheterization revealed minimal disease. Cardiac magnetic resonance imaging was performed, which revealed findings of perfusion defects and microvascular obstruction, consistent with the pathophysiology of catastrophic antiphospholipid syndrome (CAPS). Diagnosis was made based on supportive imaging, including head magnetic resonance imaging (MRI) revealing multifocal, acute strokes; microvascular thrombosis in the dermis; and subacute renal infarctions. The patient was anticoagulated with intravenous unfractionated heparin and received high-dose methylprednisolone, plasmapheresis, intravenous immunoglobulin, and one dose each of rituximab and cyclophosphamide. She convalesced with eventual myocardial recovery after a complicated course. The diagnosis of CAPS relies on the presence of (1) antiphospholipid antibodies and (2) involvement of multiple organs in a microangiopathic thrombotic process with a close temporal association. The myocardium is frequently affected, and heart failure, either as the presenting symptom or cause of death, is common. Despite echocardiographic evidence of myocardial dysfunction in such patients, MRIs of CAPS have not previously been reported. This case highlights the utility in assessing the involvement of the myocardium by the microangiopathic process with MRI. Because the diagnosis of CAPS requires involvement in multiple organ systems, cardiac MRI is likely an underused tool that not only reaffirms the pathophysiology of CAPS, but could also clue clinicians in to the

  14. Cardiac function and myocardial perfusion immediately following maximal treadmill exercise inside the MRI room

    Directory of Open Access Journals (Sweden)

    Ballinger Michelle R

    2008-01-01

    Full Text Available Abstract Treadmill exercise stress testing is an essential tool in the prevention, detection, and treatment of a broad spectrum of cardiovascular disease. After maximal exercise, cardiac images at peak stress are typically acquired using nuclear scintigraphy or echocardiography, both of which have inherent limitations. Although CMR offers superior image quality, the lack of MRI-compatible exercise and monitoring equipment has prevented the realization of treadmill exercise CMR. It is critical to commence imaging as quickly as possible after exercise to capture exercise-induced cardiac wall motion abnormalities. We modified a commercial treadmill such that it could be safely positioned inside the MRI room to minimize the distance between the treadmill and the scan table. We optimized the treadmill exercise CMR protocol in 20 healthy volunteers and successfully imaged cardiac function and myocardial perfusion at peak stress, followed by viability imaging at rest. Imaging commenced an average of 30 seconds after maximal exercise. Real-time cine of seven slices with no breath-hold and no ECG-gating was completed within 45 seconds of exercise, immediately followed by stress perfusion imaging of three short-axis slices which showed an average time to peak enhancement within 57 seconds of exercise. We observed a 3.1-fold increase in cardiac output and a myocardial perfusion reserve index of 1.9, which agree with reported values for healthy subjects at peak stress. This study successfully demonstrates in-room treadmill exercise CMR in healthy volunteers, but confirmation of feasibility in patients with heart disease is still needed.

  15. Feasibility of MRI of the fetal heart with balanced steady-state free precession sequence along fetal body and cardiac planes.

    Science.gov (United States)

    Saleem, Sahar N

    2008-10-01

    The purpose of this study was to evaluate the feasibility of imaging the fetal heart with a balanced steady-state free precession MRI sequence along the body and cardiac axes after inadequate echocardiography. After technically inadequate echocardiography, MRI was performed on 20 fetuses (mean gestational age, 24 weeks; range, 18-32 weeks) at risk of congenital heart disease. MRI was attempted along the three fetal body planes (n = 20) and cardiac axes (n = 3) without fetal sedation. The images were analyzed with an anatomic segmental approach. Each feature was classified as well visualized or poorly or not visualized. In each group, the Student's t test was used to assess the relation between visibility of fetal cardiac features and gestational age. Imaging was possible along the fetal body and cardiac axes. In the axial plane, a balanced four-chamber view was obtained in all fetuses, enabling evaluation of heart position, axis, chambers, and interventricular septum. The left and right ventricular outflow tracts were well visualized in 12 (60%) and nine (45%) of the fetuses, respectively; the three-vessel view was obtained in 10 fetuses (50%). With the combination of sagittal and coronal views, both ventricular outflow tracts were assessed in all fetuses. The superior and inferior venae cavae were identified in all fetuses, and at least one pulmonary vein was visualized in 17 fetuses (85%). There were no statistically significant differences between gestational age and lack of visualization of a cardiac feature that was attributed to fetal motion. MRI of the fetal heart with a steady-state free precession sequence in multiple planes and image analysis with an anatomic segmental approach to congenital heart disease are possible in situations that limit echocardiography.

  16. TU-G-BRA-08: BEST IN PHYSICS (JOINT IMAGING-THERAPY): Hybrid PET-MRI Imaging of Acute Radiation Induced Cardiac Toxicity

    International Nuclear Information System (INIS)

    El-Sherif, O; Xhaferllari, I; Gaede, S; Sykes, J; Butler, J; Wisenberg, G; Prato, F

    2015-01-01

    Purpose: To identify the presence of low-dose radiation induced cardiac toxicity in a canine model using hybrid positron emission tomography (PET) and magnetic resonance imaging (MRI). Methods: Research ethics board approval was obtained for a longitudinal imaging study of 5 canines after cardiac irradiation. Animals were imaged at baseline, 1 week post cardiac irradiation, and 1 month post cardiac irradiation using a hybrid PET- MRI system (Biograph mMR, Siemens Healthcare). The imaging protocol was designed to assess acute changes in myocardial perfusion and inflammation. Myocardial perfusion imaging was performed using N13-ammonia tracer followed by a dynamic PET acquisition scan. A compartmental tracer kinetic model was used for absolute perfusion quantification. Myocardial inflammation imaging was performed using F18-fluorodeoxyglucose (FDG) tracer. The standard uptake value (SUV) over a region encompassing the whole heart was used to compare FDG scans. All animals received a simulation CT scan (GE Medical Systems) for radiation treatment planning. Radiation treatment plans were created using the Pinncale3 treatment planning system (Philips Radiation Oncology Systems) and designed to resemble the typical cardiac exposure during left-sided breast cancer radiotherapy. Cardiac irradiations were performed in a single fraction using a TrueBeam linear accelerator (Varian Medical Systems). Results: The delivered dose (mean ± standard deviation) to heart was 1.8±0.2 Gy. Reductions in myocardial stress perfusion relative to baseline were observed in 2 of the 5 animals 1 month post radiation. A global inflammatory response 1 month post radiation was observed in 4 of the 5 animals. The calculated SUV at 1 month post radiation was significantly higher (p=0.05) than the baseline SUV. Conclusion: Low doses of cardiac irradiation (< 2 Gy) may lead to myocardial perfusion defects and a global inflammatory response that can be detectable as early as 1 month post irradiation

  17. TU-G-BRA-08: BEST IN PHYSICS (JOINT IMAGING-THERAPY): Hybrid PET-MRI Imaging of Acute Radiation Induced Cardiac Toxicity

    Energy Technology Data Exchange (ETDEWEB)

    El-Sherif, O; Xhaferllari, I; Gaede, S [Western Univeristy, London, ON (United Kingdom); London Regional Cancer Program, London, ON (United Kingdom); Sykes, J; Butler, J [Lawson Health Research Institute, London, ON (United Kingdom); Wisenberg, G; Prato, F [Western Univeristy, London, ON (United Kingdom); Lawson Health Research Institute, London, ON (United Kingdom)

    2015-06-15

    Purpose: To identify the presence of low-dose radiation induced cardiac toxicity in a canine model using hybrid positron emission tomography (PET) and magnetic resonance imaging (MRI). Methods: Research ethics board approval was obtained for a longitudinal imaging study of 5 canines after cardiac irradiation. Animals were imaged at baseline, 1 week post cardiac irradiation, and 1 month post cardiac irradiation using a hybrid PET- MRI system (Biograph mMR, Siemens Healthcare). The imaging protocol was designed to assess acute changes in myocardial perfusion and inflammation. Myocardial perfusion imaging was performed using N13-ammonia tracer followed by a dynamic PET acquisition scan. A compartmental tracer kinetic model was used for absolute perfusion quantification. Myocardial inflammation imaging was performed using F18-fluorodeoxyglucose (FDG) tracer. The standard uptake value (SUV) over a region encompassing the whole heart was used to compare FDG scans. All animals received a simulation CT scan (GE Medical Systems) for radiation treatment planning. Radiation treatment plans were created using the Pinncale3 treatment planning system (Philips Radiation Oncology Systems) and designed to resemble the typical cardiac exposure during left-sided breast cancer radiotherapy. Cardiac irradiations were performed in a single fraction using a TrueBeam linear accelerator (Varian Medical Systems). Results: The delivered dose (mean ± standard deviation) to heart was 1.8±0.2 Gy. Reductions in myocardial stress perfusion relative to baseline were observed in 2 of the 5 animals 1 month post radiation. A global inflammatory response 1 month post radiation was observed in 4 of the 5 animals. The calculated SUV at 1 month post radiation was significantly higher (p=0.05) than the baseline SUV. Conclusion: Low doses of cardiac irradiation (< 2 Gy) may lead to myocardial perfusion defects and a global inflammatory response that can be detectable as early as 1 month post irradiation

  18. Quantification of left ventricular volumes from cardiac cine MRI using active contour model combined with gradient vector flow

    International Nuclear Information System (INIS)

    Tanki, Nobuyoshi; Murase, Kenya; Kumashiro, Masayuki; Momoi, Risa; Yang, Xiaomei; Tabuchi, Takashi; Nagayama, Masako; Watanabe, Yuji

    2005-01-01

    We investigated the feasibility of combining the active contour model with gradient vector flow (Snakes-GVF) to estimate left ventricular (LV) volumes from cardiac cine magnetic resonance imaging (MRI). MRI data were acquired from 27 patients, including 14 adults (9 men, 5 women, 55.0±23.3 years) and 13 children (10 boys, 3 girls, 2.7±2.1 years) using Gyroscan Intera (1.5 Tesla, Philips Medical Systems). LV volumes were calculated by adding the areas surrounded by the contour extracted by Snakes-GVF and compared with volumes estimated by manual tracing. Those estimated by Snakes-GVF [y (mL)] correlated well with those estimated by manual tracing [x (mL)]. In adult cases, the regression equation and correlation coefficient were y=1.008x-0.517 and 0.996, respectively. In pediatric cases, they were y=1.174x-2.542 and 0.992, respectively. In conclusion, Snakes-GVF is a powerful and useful tool for quantifying LV volumes using cardiac MRI. (author)

  19. Echocardiography and cardiac MRI in mutation-negative hypertrophic cardiomyopathy in an older patient: a case defining the need for ICD.

    Science.gov (United States)

    Rodriguez, Fatima; Degnan, Kathleen O; Seidman, Christine E; Mangion, Judy R

    2014-08-01

    We report the case of a 67-year-old man with hypertrophic cardiomyopathy who presented for a second opinion about implantable cardio-defibrillator (ICD) placement after a witnessed syncopal episode. Despite his older age, being mutation-negative, and having a maximal septal thickness of 2.2 cm on echocardiography, he demonstrated rapid progression of myocardial fibrosis on cardiac MRI, correlating to ventricular tachyarrhythmias and syncope. We review the role of echocardiography and cardiac MRI in optimizing medical care for such patients who may not otherwise meet criteria for an ICD placement or further interventions. © 2014, Wiley Periodicals, Inc.

  20. Normal cardiac diameters in cine-MRI of the heart

    International Nuclear Information System (INIS)

    Hergan, K.; Schuster, A.; Mair, M.; Burger, R.; Toepker, M.

    2004-01-01

    Purpose: To measure the normal diameters of cardiac cavities in standard cardiac views using cine MRI. Materials and Methods: Fifty-six volunteers were examined (27 male, 29 female) on a 1.5 T MR unit with ECG-triggered single shot free precision (SSFP) cine MR sequences and parallel image acquisition. Standardized echocardiographic planes were used to depict the heart of all volunteers (short axis, 4-chamber view, left and right 2-chamber views). The different diameters of the cardiac cavities were measured using a fixed protocol. Results: For the estimation of ventricular dilatation, the important female/male cross diameters of the left ventricle are 45.2±3.4/51.6±4.6 mm diastolic and 30.5±3.5/33.8±3.6 mm systolic, and of the right ventricle 30.7±3.8/37.1±5.9 mm diastolic and 22.3±3.8/28.1±4.4 mm systolic. For the determination of a left ventricular hypertrophy, relevant septal wall thickness measured in the short axis of the left ventricle of female/male volunteers are 8.0±1.0/9.9±1.2 mm diastolic and 10.9±1.4/13.6±1.9 mm systolic. The measured normal values of male volunteers were generally higher than those of female volunteers. The thickness of the ventricular septum correlated well when measured in the short axis and 4-chamber view. When measured in the 4-chamber view, the longitudinal diameter of the ventricles had a higher value in diastole and a lower value in systole, compared to the 2-chamber views of the right and left cardiac cavities. The atrial longitudinal diameters were higher in the 4-chamber view compared to the 2-chamber views, without any difference in systole or diastole. Conclusion: Diameters of cardiac cavities are easily and quickly measured. Using the tables with the normal values published here, it is simple to estimate an abnormal size of the heart. (orig.)

  1. MRI-based volumetric assessment of cardiac anatomy and dose reduction via active breathing control during irradiation for left-sided breast cancer

    International Nuclear Information System (INIS)

    Krauss, Daniel J.; Kestin, Larry L.; Raff, Gilbert; Yan Di; Wong, John; Gentry, Ralph; Letts, Nicola; Vargas, Carlos E.; Martinez, Alvaro A.; Vicini, Frank A.

    2005-01-01

    Purpose: Heart dose-volume analysis using computed tomography (CT) is limited because of motion artifact and poor delineation between myocardium and ventricular space. We used dedicated cardiac magnetic resonance imaging (MRI) to quantify exclusion of left ventricular (LV) myocardium via active breathing control (ABC) during left breast irradiation and to determine the correlation between irradiated whole heart and LV volumes. Methods and materials: Fifteen patients who completed adjuvant irradiation for early-stage left breast cancer participated. Treatment consisted of 45 Gy to the entire breast using ABC followed by a 16-Gy electron boost to the lumpectomy cavity. Patients underwent planning CT scans in free breathing (FB) and moderate deep inspiration breath hold (mDIBH). Electrocardiogram-gated cardiac MRI was performed in the treatment position using α-cradle immobilization. MRI scans were acquired in late diastole (LD), mid-diastole (MD), and systole (S) for both FB and mDIBH. After image fusion with the patients' radiation therapy planning CT scan, MRI LV volumes were defined for the three examined phases of the cardiac cycle, and comparative dose-volume analysis was performed. Results: Cardiac volume definition was found to differ significantly because of combinations of respiratory and intrinsic heart motion. The fraction of LV myocardium receiving 50% (22.5 Gy) of the prescribed whole breast dose (V 22.5 ) was reduced by 85.3%, 91.8%, and 94.6% via ABC for LD, MD, and S, respectively. Linear regression revealed strong correlation between MRI-defined whole heart and LV V 22.5 reduction via ABC, suggesting that LV myocardium accounts for up to approximately 50% of the excluded heart volume through this technique. Significant but weaker correlations were noted between CT-defined whole heart and LV V 22.5 reductions with marked variability in the measurements of patients with larger amounts of heart in the treatment field. Conclusions: Cardiac MRI

  2. Imaging in cardiac mass lesions

    International Nuclear Information System (INIS)

    Mundinger, A.; Gruber, H.P.; Dinkel, E.; Geibel, A.; Beck, A.; Wimmer, B.; Schlosser, V.

    1992-01-01

    In 26 patients with cardiac mass lesions confirmed by surgery, diagnostic imaging was performed preoperatively by means of two-dimensional echocardiography (26 patients), angiography (12 patients), correlative computed tomography (CT, 8 patients), and magnetic resonance imaging (MRI, 3 patients). Two-dimensional echocardiography correctly identified the cardiac masses in all patients. Angiography missed two of 12 cardiac masses; CT missed one of eight. MRI identified three of three cardiac masses. Although the sensitivity of two-dimensional echocardiography was high (100%), all methods lacked specificity. None of the methods allowed differentiation between myxoma (n=13) and thrombus (n=7). Malignancy of the lesions was successfully predicted by noninvasive imaging methods in all six patients. However, CT and MRI provided additional information concerning cardiac mural infiltration, pericardial involvement, and extracardiac tumor extension, and should be integrated within a preoperative imaging strategy. Thus two-dimensional echocardiography is the method of choice for primary assessment of patients with suspected cardiac masses. Further preoperative imaging by CT or MRI can be limited to patients with malignancies suspected on the grounds of pericardial effusion or other clinical results. (author)

  3. Safety work with MRI devices in medicine

    International Nuclear Information System (INIS)

    Zivkovic, D.; Hrnjak, M.

    1999-01-01

    This paper gives the basis of biological effects of physical factors which could affect personnel working on MRI devices and patients, and corresponding protection measures. Medical personnel working with MRI devices and patients could be exposed to static magnetic field, time varying fields and radiofrequency radiation, danger from electric current and chemical matters, and there is a high risk from moving metal objects which could wound the persons near-by. The protection from static magnetic field could be ensured by increasing the distance from the source. If MRI device is put in Faradays cage it could be corresponding protection of radiofrequency radiation. (author)

  4. Comparison between (99m)Tc-diphosphonate imaging and MRI with late gadolinium enhancement in evaluating cardiac involvement in patients with transthyretin familial amyloid polyneuropathy.

    Science.gov (United States)

    Minutoli, Fabio; Di Bella, Gianluca; Mazzeo, Anna; Donato, Rocco; Russo, Massimo; Scribano, Emanuele; Baldari, Sergio

    2013-03-01

    Cardiac involvement is not rare in systemic amyloidosis and is associated with poor prognosis. Both (99m)Tc-diphosphonate imaging and cardiac MRI with late gadolinium enhancement are considered valuable tools in revealing amyloid deposition in the myocardium; however, to our knowledge, no comparative study between the two techniques exists. We compared findings of these two techniques in patients with transthyretin-familial amyloid polyneuropathy (FAP). Eighteen patients with transthyretin-FAP underwent (99m)Tc-diphosphonate imaging and MRI with late gadolinium enhancement. Images were visually evaluated by independent readers to determine the presence of radiotracer accumulation or late gadolinium enhancement-positive areas at the level of cardiac chambers. Interobserver agreement ranged from moderate to very good for (99m)Tc-diphosphonate imaging findings and was very good for findings of MRI with late gadolinium enhancement. Left ventricle (LV) radiotracer uptake was found in 10 of 18 patients, whereas LV late gadolinium enhancement-positive areas were found in eight of 18 patients (χ(2) = 0.9; p = 0.343). One hundred fifty-nine LV segments showed (99m)Tc-diphosphonate accumulation, and 57 LV segments were late gadolinium enhancement positive (p < 0.0001). Radiotracer uptake was found in the right ventricle (RV) in eight patients and in both atria in five patients, whereas MRI showed that RV was involved in three patients and both atria in six patients; the differences were not statistically significant (RV, p = 0.07; atria, p = 1). Intermodality agreement between (99m)Tc-diphosphonate imaging and MRI ranged from fair to good. Our study shows that, although (99m)Tc-diphosphonate imaging and MRI with late gadolinium enhancement have similar capabilities to identify patients with myocardial amyloid deposition, cardiac amyloid infiltration burden can be significantly underestimated by visual analysis of MRI with late gadolinium enhancement compared with (99m

  5. Modelling Cardiac Signal as a Confound in EEG-fMRI and its Application in Focal Epilepsy

    DEFF Research Database (Denmark)

    Liston, Adam David; Salek-Haddadi, Afraim; Hamandi, Khalid

    2005-01-01

    Cardiac noise has been shown to reduce the sensitivity of functional Magnetic Resonance Imaging (fMRI) to an experimental effect due to its confounding presence in the blood oxygenation level-dependent (BOLD) signal. Its effect is most severe in particular regions of the brain and a method is yet...

  6. Motion Correction using Coil Arrays (MOCCA) for Free-Breathing Cardiac Cine MRI

    Science.gov (United States)

    Hu, Peng; Hong, Susie; Moghari, Mehdi H.; Goddu, Beth; Goepfert, Lois; Kissinger, Kraig V.; Hauser, Thomas H.; Manning, Warren J; Nezafat, Reza

    2014-01-01

    In this study, we present a motion compensation technique based on coil arrays (MOCCA) and evaluate its application in free-breathing respiratory self-gated cine MRI. MOCCA takes advantages of the fact that motion-induced changes in k-space signal are modulated by individual coil sensitivity profiles. In the proposed implementation of MOCCA self-gating for free-breathing cine MRI, the k-space center line is acquired at the beginning of each k-space segment for each cardiac cycle with 4 repetitions. For each k-space segment, the k-space center line acquired immediately before was used to select one of the 4 acquired repetitions to be included in the final self-gated cine image by calculating the cross-correlation between the k-space center line with a reference line. The proposed method was tested on a cohort of healthy adult subjects for subjective image quality and objective blood-myocardium border sharpness. The method was also tested on a cohort of patients to compare the left and right ventricular volumes and ejection fraction measurements with that of standard breath-hold cine MRI. Our data indicate that the proposed MOCCA method provides significantly improved image quality and sharpness compared to free-breathing cine without respiratory self-gating, and provides similar volume measurements compared with breath-hold cine MRI. PMID:21773986

  7. WE-FG-202-06: The Use of Hybrid PET MRI for Identifying the Presence of Cardiac Inflammation Following External Beam Irradiation

    International Nuclear Information System (INIS)

    El-Sherif, O; Xhaferllari, I; Battista, J; Sykes, J; Butler, J; Wisenberg, G; Prato, F; Gaede, S

    2016-01-01

    Purpose: To monitor the evolution of radiation-induced cardiac inflammation in a canine model using hybrid positron emission tomography (PET/magnetic resonance imaging (MRI). Methods: Research ethics approval was obtained for a longitudinal imaging study of 5 canines after cardiac irradiation. Animals were imaged at baseline, 3 months, 6 months, and 12 months post cardiac irradiation using a hybrid PET-MRI system (Biograph mMR, Siemens Healthcare). The imaging protocol was designed to assess changes in cardiac inflammation using 18 F-fluorodeoxyglucose ( 18 F-FDG) PET tracer. In order to image cardiac inflammation, the normal myocardial uptake of glucose was suppressed prior to the injection of 18 F-FDG. The suppression of glycolysis was achieved through; fasting (16–21 hours prior to the start of imaging) and an intravenous injection of heparin immediately followed by a 20% lipid infusion 20 min prior to the injection of 18 F-FDG. The standard uptake value (SUV) obtained from 17 myocardial regions were used to compare FDG scans. All animals received a simulation CT scan (GE Medical Systems) for radiation treatment planning. Radiation treatment plans were created using the Pinncale3 treatment planning system (Philips Radiation Oncology Systems) and designed to resemble the typical cardiac exposure during left-sided breast cancer radiotherapy. Cardiac irradiations were performed in a single fraction using a TrueBeam linear accelerator (Varian Medical Systems). Results: The delivered dose (mean ± standard error) to heart, left ventricle, and left anterior descending artery were 1.7±0.1 Gy, 2.7±0.1 Gy, and 5.5±0.3 Gy respectively. At these doses, a significant increase in 18 F-FDG uptake within the entire heart relative to baseline (1.1±0.02 g/ml) uptake was observed. 18 F-FDG uptake at 3 months, 6 months, and 12 months post irradiation were 1.8±0.03 g/ml, 2.4±0.06 g/ml, and 2.6±0.11 g/ml respectively. Conclusion: Low doses of limited cardiac irradiation

  8. WE-FG-202-06: The Use of Hybrid PET MRI for Identifying the Presence of Cardiac Inflammation Following External Beam Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    El-Sherif, O; Xhaferllari, I; Battista, J [Western University, London, ON (United Kingdom); London Regional Cancer Program, London, ON (United Kingdom); Sykes, J; Butler, J [Thames Valley Veterinary Services, London, Ontario (Canada); Lawson Health Research Institute, London, Ontario (Canada); Wisenberg, G; Prato, F [Western University, London, ON (United Kingdom); Lawson Health Research Institute, London, Ontario (Canada); Gaede, S [Western University, London, ON (United Kingdom); London Regional Cancer Program, London, ON (United Kingdom); Lawson Health Research Institute, London, Ontario (Canada)

    2016-06-15

    Purpose: To monitor the evolution of radiation-induced cardiac inflammation in a canine model using hybrid positron emission tomography (PET/magnetic resonance imaging (MRI). Methods: Research ethics approval was obtained for a longitudinal imaging study of 5 canines after cardiac irradiation. Animals were imaged at baseline, 3 months, 6 months, and 12 months post cardiac irradiation using a hybrid PET-MRI system (Biograph mMR, Siemens Healthcare). The imaging protocol was designed to assess changes in cardiac inflammation using {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) PET tracer. In order to image cardiac inflammation, the normal myocardial uptake of glucose was suppressed prior to the injection of {sup 18}F-FDG. The suppression of glycolysis was achieved through; fasting (16–21 hours prior to the start of imaging) and an intravenous injection of heparin immediately followed by a 20% lipid infusion 20 min prior to the injection of {sup 18}F-FDG. The standard uptake value (SUV) obtained from 17 myocardial regions were used to compare FDG scans. All animals received a simulation CT scan (GE Medical Systems) for radiation treatment planning. Radiation treatment plans were created using the Pinncale3 treatment planning system (Philips Radiation Oncology Systems) and designed to resemble the typical cardiac exposure during left-sided breast cancer radiotherapy. Cardiac irradiations were performed in a single fraction using a TrueBeam linear accelerator (Varian Medical Systems). Results: The delivered dose (mean ± standard error) to heart, left ventricle, and left anterior descending artery were 1.7±0.1 Gy, 2.7±0.1 Gy, and 5.5±0.3 Gy respectively. At these doses, a significant increase in {sup 18}F-FDG uptake within the entire heart relative to baseline (1.1±0.02 g/ml) uptake was observed. {sup 18}F-FDG uptake at 3 months, 6 months, and 12 months post irradiation were 1.8±0.03 g/ml, 2.4±0.06 g/ml, and 2.6±0.11 g/ml respectively. Conclusion: Low doses of

  9. Characterization of cardiac flow in heart disease patients by computational fluid dynamics and 4D flow MRI

    Science.gov (United States)

    Lantz, Jonas; Gupta, Vikas; Henriksson, Lilian; Karlsson, Matts; Persson, Ander; Carhall, Carljohan; Ebbers, Tino

    2017-11-01

    In this study, cardiac blood flow was simulated using Computational Fluid Dynamics and compared to in vivo flow measurements by 4D Flow MRI. In total, nine patients with various heart diseases were studied. Geometry and heart wall motion for the simulations were obtained from clinical CT measurements, with 0.3x0.3x0.3 mm spatial resolution and 20 time frames covering one heartbeat. The CFD simulations included pulmonary veins, left atrium and ventricle, mitral and aortic valve, and ascending aorta. Mesh sizes were on the order of 6-16 million cells, depending on the size of the heart, in order to resolve both papillary muscles and trabeculae. The computed flow field agreed visually very well with 4D Flow MRI, with characteristic vortices and flow structures seen in both techniques. Regression analysis showed that peak flow rate as well as stroke volume had an excellent agreement for the two techniques. We demonstrated the feasibility, and more importantly, fidelity of cardiac flow simulations by comparing CFD results to in vivo measurements. Both qualitative and quantitative results agreed well with the 4D Flow MRI measurements. Also, the developed simulation methodology enables ``what if'' scenarios, such as optimization of valve replacement and other surgical procedures. Funded by the Wallenberg Foundation.

  10. Automatic segmentation of the right ventricle from cardiac MRI using a learning-based approach.

    Science.gov (United States)

    Avendi, Michael R; Kheradvar, Arash; Jafarkhani, Hamid

    2017-12-01

    This study aims to accurately segment the right ventricle (RV) from cardiac MRI using a fully automatic learning-based method. The proposed method uses deep learning algorithms, i.e., convolutional neural networks and stacked autoencoders, for automatic detection and initial segmentation of the RV chamber. The initial segmentation is then combined with the deformable models to improve the accuracy and robustness of the process. We trained our algorithm using 16 cardiac MRI datasets of the MICCAI 2012 RV Segmentation Challenge database and validated our technique using the rest of the dataset (32 subjects). An average Dice metric of 82.5% along with an average Hausdorff distance of 7.85 mm were achieved for all the studied subjects. Furthermore, a high correlation and level of agreement with the ground truth contours for end-diastolic volume (0.98), end-systolic volume (0.99), and ejection fraction (0.93) were observed. Our results show that deep learning algorithms can be effectively used for automatic segmentation of the RV. Computed quantitative metrics of our method outperformed that of the existing techniques participated in the MICCAI 2012 challenge, as reported by the challenge organizers. Magn Reson Med 78:2439-2448, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  11. Relationship between heart rate and quiescent interval of the cardiac cycle in children using MRI

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Wei [Texas Children' s Hospital, E. B. Singleton Department of Pediatric Radiology, Houston, TX (United States); Bogale, Saivivek [Baylor University Medical Center, Department of Radiology, Dallas, TX (United States); Golriz, Farahnaz [Baylor College of Medicine, Department of Radiology, Houston, TX (United States); Krishnamurthy, Rajesh [Nationwide Children' s Hospital, Department of Diagnostic Radiology, Columbus, OH (United States)

    2017-11-15

    Imaging the heart in children comes with the challenge of constant cardiac motion. A prospective electrocardiography-triggered CT scan allows for scanning during a predetermined phase of the cardiac cycle with least motion. This technique requires knowing the optimal quiescent intervals of cardiac cycles in a pediatric population. To evaluate high-temporal-resolution cine MRI of the heart in children to determine the relationship of heart rate to the optimal quiescent interval within the cardiac cycle. We included a total of 225 consecutive patients ages 0-18 years who had high-temporal-resolution cine steady-state free-precession sequence performed as part of a magnetic resonance imaging (MRI) or magnetic resonance angiography study of the heart. We determined the location and duration of the quiescent interval in systole and diastole for heart rates ranging 40-178 beats per minute (bpm). We performed the Wilcoxon signed rank test to compare the duration of quiescent interval in systole and diastole for each heart rate group. The duration of the quiescent interval at heart rates <80 bpm and >90 bpm was significantly longer in diastole and systole, respectively (P<.0001 for all ranges, except for 90-99 bpm [P=.02]). For heart rates 80-89 bpm, diastolic interval was longer than systolic interval, but the difference was not statistically significant (P=.06). We created a chart depicting optimal quiescent intervals across a range of heart rates that could be applied for prospective electrocardiography-triggered CT imaging of the heart. The optimal quiescent interval at heart rates <80 bpm is in diastole and at heart rates ≥90 bpm is in systole. The period of quiescence at heart rates 80-89 bpm is uniformly short in systole and diastole. (orig.)

  12. Accelerated cardiac cine MRI using locally low rank and finite difference constraints.

    Science.gov (United States)

    Miao, Xin; Lingala, Sajan Goud; Guo, Yi; Jao, Terrence; Usman, Muhammad; Prieto, Claudia; Nayak, Krishna S

    2016-07-01

    To evaluate the potential value of combining multiple constraints for highly accelerated cardiac cine MRI. A locally low rank (LLR) constraint and a temporal finite difference (FD) constraint were combined to reconstruct cardiac cine data from highly undersampled measurements. Retrospectively undersampled 2D Cartesian reconstructions were quantitatively evaluated against fully-sampled data using normalized root mean square error, structural similarity index (SSIM) and high frequency error norm (HFEN). This method was also applied to 2D golden-angle radial real-time imaging to facilitate single breath-hold whole-heart cine (12 short-axis slices, 9-13s single breath hold). Reconstruction was compared against state-of-the-art constrained reconstruction methods: LLR, FD, and k-t SLR. At 10 to 60 spokes/frame, LLR+FD better preserved fine structures and depicted myocardial motion with reduced spatio-temporal blurring in comparison to existing methods. LLR yielded higher SSIM ranking than FD; FD had higher HFEN ranking than LLR. LLR+FD combined the complimentary advantages of the two, and ranked the highest in all metrics for all retrospective undersampled cases. Single breath-hold multi-slice cardiac cine with prospective undersampling was enabled with in-plane spatio-temporal resolutions of 2×2mm(2) and 40ms. Highly accelerated cardiac cine is enabled by the combination of 2D undersampling and the synergistic use of LLR and FD constraints. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Scoring of late gadolinium enhancement in cardiac magnetic resonance imaging can predict cardiac events in patients with hypertrophic cardiomyopathy

    International Nuclear Information System (INIS)

    Nojiri, Ayumi; Hongo, Kenichi; Kawai, Makoto; Komukai, Kimiaki; Sakuma, Toru; Taniguchi, Ikuo; Yoshimura, Michihiro

    2011-01-01

    Late gadolinium enhancement (LGE) of cardiac magnetic resonance imaging (MRI) represents myocardial fibrosis and may be related to the clinical outcome of various heart diseases. This study evaluated the relationship between LGE and cardiac events in hypertrophic cardiomyopathy (HCM) using a new scoring method. This study retrospectively followed 46 HCM patients without heart failure symptoms for 3.8±1.8 years. Gadolinium-enhanced cardiac MRI was performed in all patients. Cardiac events including newly developed heart failure or ventricular tachyarrhythmia were evaluated during the follow-up period. We evaluated the predictive factors to identify the patients with cardiac events. None of the risk factors reported to be related to poor outcome or the existence of LGE alone could predict cardiac events, which might be due to the small number of subjects investigated in this study. A new scoring method for LGE-positive areas (LGE score) was applied and higher LGE score can predict cardiac events in this study population. The proposed LGE score for cardiac MRI is considered to be a potentially valid method for assessing cardiac events in HCM patients. (author)

  14. Non-cardiac findings on coronary computed tomography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Dewey, Marc; Schnapauff, Dirk; Teige, Florian; Hamm, Bernd

    2007-01-01

    Both multislice computed tomography (CT) and magnetic resonance imaging (MRI) are emerging as methods to detect coronary artery stenoses and assess cardiac function and morphology. Non-cardiac structures are also amenable to assessment by these non-invasive tests. We investigated the rate of significant and insignificant non-cardiac findings using CT and MRI. A total of 108 consecutive patients suspected of having coronary artery disease and without contraindications to CT and MRI were included in this study. Significant non-cardiac findings were defined as findings that required additional clinical or radiological follow-up. CT and MR images were read independently in a blinded fashion. CT yielded five significant non-cardiac findings in five patients (5%). These included a pulmonary embolism, large pleural effusions, sarcoid, a large hiatal hernia, and a pulmonary nodule (>1.0 cm). Two of these significant non-cardiac findings were also seen on MRI (pleural effusions and sarcoid, 2%). Insignificant non-cardiac findings were more frequent than significant findings on both CT (n = 11, 10%) and MRI (n = 7, 6%). Incidental non-cardiac findings on CT and MRI of the coronary arteries are common, which is why images should be analyzed by radiologists to ensure that important findings are not missed and unnecessary follow-up examinations are avoided. (orig.)

  15. Non-cardiac findings on coronary computed tomography and magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc; Schnapauff, Dirk; Teige, Florian; Hamm, Bernd [Charite-Universitaetsmedizin Berlin, Humboldt-Universitaet zu Berlin, Department of Radiology, Chariteplatz 1, P.O. Box 10098, Berlin (Germany)

    2007-08-15

    Both multislice computed tomography (CT) and magnetic resonance imaging (MRI) are emerging as methods to detect coronary artery stenoses and assess cardiac function and morphology. Non-cardiac structures are also amenable to assessment by these non-invasive tests. We investigated the rate of significant and insignificant non-cardiac findings using CT and MRI. A total of 108 consecutive patients suspected of having coronary artery disease and without contraindications to CT and MRI were included in this study. Significant non-cardiac findings were defined as findings that required additional clinical or radiological follow-up. CT and MR images were read independently in a blinded fashion. CT yielded five significant non-cardiac findings in five patients (5%). These included a pulmonary embolism, large pleural effusions, sarcoid, a large hiatal hernia, and a pulmonary nodule (>1.0 cm). Two of these significant non-cardiac findings were also seen on MRI (pleural effusions and sarcoid, 2%). Insignificant non-cardiac findings were more frequent than significant findings on both CT (n = 11, 10%) and MRI (n = 7, 6%). Incidental non-cardiac findings on CT and MRI of the coronary arteries are common, which is why images should be analyzed by radiologists to ensure that important findings are not missed and unnecessary follow-up examinations are avoided. (orig.)

  16. Free breathing whole-heart 3D CINE MRI with self-gated Cartesian trajectory.

    Science.gov (United States)

    Usman, M; Ruijsink, B; Nazir, M S; Cruz, G; Prieto, C

    2017-05-01

    To present a method that uses a novel free-running self-gated acquisition to achieve isotropic resolution in whole heart 3D Cartesian cardiac CINE MRI. 3D cardiac CINE MRI using navigator gating results in long acquisition times. Recently, several frameworks based on self-gated non-Cartesian trajectories have been proposed to accelerate this acquisition. However, non-Cartesian reconstructions are computationally expensive due to gridding, particularly in 3D. In this work, we propose a novel highly efficient self-gated Cartesian approach for 3D cardiac CINE MRI. Acquisition is performed using CArtesian trajectory with Spiral PRofile ordering and Tiny golden angle step for eddy current reduction (so called here CASPR-Tiger). Data is acquired continuously under free breathing (retrospective ECG gating, no preparation pulses interruption) for 4-5min and 4D whole-heart volumes (3D+cardiac phases) with isotropic spatial resolution are reconstructed from all available data using a soft gating technique combined with temporal total variation (TV) constrained iterative SENSE reconstruction. For data acquired on eight healthy subjects and three patients, the reconstructed images using the proposed method had good contrast and spatio-temporal variations, correctly recovering diastolic and systolic cardiac phases. Non-significant differences (P>0.05) were observed in cardiac functional measurements obtained with proposed 3D approach and gold standard 2D multi-slice breath-hold acquisition. The proposed approach enables isotropic 3D whole heart Cartesian cardiac CINE MRI in 4 to 5min free breathing acquisition. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  17. Cardiac MRI in addition to MR angiography: a longitudinal study in vascular risk patients; Kardiale MRT als Ergaenzung zur MR-Angiografie: Eine longitudinale Studie bei vaskulaeren Risikopatienten

    Energy Technology Data Exchange (ETDEWEB)

    Seeger, A.; Grimm, F.; Fenchel, M.; Kramer, U.; Doering, J.S.; Klumpp, B.; Claussen, C.D.; Miller, S. [Abt. fuer Radiologische Diagnostik, Eberhard-Karls-Univ. Tuebingen (Germany); Scheule, A. [Abt. fuer Herz-, Thorax- und Gefaesschirurgie, Eberhard-Karls-Univ. Tuebingen (Germany); May, A.E. [Abt. fuer Kardiologie, Eberhard-Karls-Univ. Tuebingen (Germany)

    2008-05-15

    Purpose: the aim of the study was to assess the feasibility and additional diagnostic information of cardiac MRI as a supplement to state-of-the-art MR angiography (MRA) in the case of vascular risk patients. Therefore, the prevalence of delayed myocardial enhancement (DE) was determined in patients suffering from peripheral artery disease (PAD) and a clinical follow-up was evaluated after 2 years. Materials and method: 87 consecutive patients (ages 66 {+-} 10 years, 67 males) with symptomatic peripheral arterial occlusive disease (n = 68) or abdominal aortic aneurysm (n = 19) were examined using delayed cardiac enhancement (DE) within the clinical indication of MRA at a 1.5T system. A follow-up examination was carried out two years later (24 months {+-} 4 months) with regards to cardiac events (cardiac death, myocardial infarction or acute coronary syndrome, heart insufficiency, coronary revascularization). Results: in total, 40/87 patients had myocardial infarctions shown in MRI (46%). In 25 patients (29%), the myocardial infarction was already known, while in 15 patients (17%) an occult progressing infarction was diagnosed (38% of the myocardial infarcts). Follow-up data was able to be obtained after 2 years for 82 patients. 15 patients had a major cardiac event during the follow-up period, and 10 (67%) of them already showed DE in the MRI. In the group with occult progressing infarctions, cardiac events occurred in 40% (6/15 patients, cardiac death n = 1, ischemia n = 4, heart insufficiency n = 1, bypass n = 1), in patients with known infarction in 17% (4/23 patients, cardiac death n = 1, ischemia n = 3, bypass n = 2) and in 11% of patients without myocardial scars (5/44 patients, cardiac death n = 1, ischemia n = 2, heart insufficiency n = 2). (orig.)

  18. Magnetic resonance imaging for cardiac tumors

    International Nuclear Information System (INIS)

    Niwa, Koichiro; Tashima, Kazuyuki; Okajima, Yoshitomo; Nakajima, Hiromichi; Terai, Masaru; Nakajima, Hironori; Harada, Tsutomu; Ishida, Yoshikazu.

    1988-01-01

    We performed magnetic resonance imaging (MRI) in 4 patients with cardiac tumor (1 with rhabdomyoma, 1 with left atrial myxoma, and 2 with tumor of the left ventricular wall) for morphological evaluation of the tumor. ECG-gated MRI was performed by the spin echo imaging technique using a superconducting MRI system operating at 0.5 tesla. Spatial extension of the tumor was clearly demonstrated in all the patients. Gadolinium-DTPA (Gd-DTPA), was used in the 2 patients with tumor of the left ventricular myocardium to enhance the contrast, and allowed clear visualization of the tumor. These findings show the usefulness of MRI and MRI with Gd-DTPA for morphological evaluation of cardiac tumor. (author)

  19. Direct cerebral and cardiac 17O-MRI at 3 Tesla: initial results at natural abundance.

    Science.gov (United States)

    Borowiak, Robert; Groebner, Jens; Haas, Martin; Hennig, Jürgen; Bock, Michael

    2014-02-01

    To establish direct (17)O-magnetic resonance imaging (MRI) for metabolic imaging at a clinical field strength of 3 T. An experimental setup including a surface coil and transmit/receive switch was constructed. Natural abundance in vivo brain images of a volunteer were acquired with a radial three-dimensional (3D) sequence in the visual cortex and in the heart with electrocardiogram (ECG)-gating. In the brain, a signal-to-noise ratio of 36 was found at a nominal resolution of (5.6 mm)(3), and a transverse relaxation time of T(2)* = (1.9 ± 0.2) ms was obtained. In the heart (17)O images were acquired with a temporal resolution of 200 ms. Cerebral and cardiac (17)O-MRI at natural abundance is feasible at 3 T.

  20. Quantitative Assessment of Left Ventricular Function and Myocardial Mass: A Comparison of Coronary CT Angiography with Cardiac MRI and Echocardiography

    International Nuclear Information System (INIS)

    Kara, Bedia; Nayman, Alaaddin; Guler, Ibrahim; Gul, Enes Elvin; Koplay, Mustafa; Paksoy, Yahya

    2016-01-01

    The purpose of this study was to compare the left ventricular parameters obtained from multi-detector row computed tomography (MDCT) studies with two-dimensional echocardiography (2DE), and magnetic resonance imaging (MRI), which is accepted as the gold standard in the evaluation of left ventricular functions. The study also aimed to evaluate whether or not there is a relationship between the MR-Argus and CMR tools software programs which are used in post-process calculations of data obtained by MRI. Forty patients with an average age of 51.4±14.9 years who had been scanned with cardiac MDCT were evaluated with cardiac MRI and 2DE. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), cardiac output (CO), and myocardial mass values calculated by MDCT, MRI, and 2DE were compared with each other. Two different MR software programs were used to compare left ventricular functions. The CMR tools LV tutorials method is accepted as the gold standard because it can be used in three-dimensional functional evaluation. The Pearson Correlation and Bland-Altman analysis were performed to compare the results from the two MR methods (MR-Argus and CMR tools) and the results from both the MDCT and the 2DE with the CMR tools results. Strong positive correlations for EF values were found between the MDCT and CMR tools (r=0.702 p<0.001), and between the MR-Argus and CMR tools (r=0.746 p<0.001). The correlation between the 2DE and CMR tools (r=0.449 p<0.004), however, was only moderate. Similar results were obtained for the other parameters. The strongest correlation for ESV, EDV, and EF was between the two MR software programs. The correlation coefficient between the MDCT and CMR tools is close to the correlation coefficient between the two software programs. While the correlation between 2DE and CMR tools was satisfactory for ESV, EDV, and CO values, it was at a moderate level for the other parameters. Left ventricular functional analysis

  1. MR-based attenuation correction for cardiac FDG PET on a hybrid PET/MRI scanner: comparison with standard CT attenuation correction

    Energy Technology Data Exchange (ETDEWEB)

    Vontobel, Jan; Liga, Riccardo; Possner, Mathias; Clerc, Olivier F.; Mikulicic, Fran; Veit-Haibach, Patrick; Voert, Edwin E.G.W. ter; Fuchs, Tobias A.; Stehli, Julia; Pazhenkottil, Aju P.; Benz, Dominik C.; Graeni, Christoph; Gaemperli, Oliver; Herzog, Bernhard; Buechel, Ronny R.; Kaufmann, Philipp A. [University Hospital Zurich, Department of Nuclear Medicine, Zurich (Switzerland)

    2015-09-15

    The aim of this study was to evaluate the feasibility of attenuation correction (AC) for cardiac {sup 18}F-labelled fluorodeoxyglucose (FDG) positron emission tomography (PET) using MR-based attenuation maps. We included 23 patients with no known cardiac history undergoing whole-body FDG PET/CT imaging for oncological indications on a PET/CT scanner using time-of-flight (TOF) and subsequent whole-body PET/MR imaging on an investigational hybrid PET/MRI scanner. Data sets from PET/MRI (with and without TOF) were reconstructed using MR AC and semi-quantitative segmental (20-segment model) myocardial tracer uptake (per cent of maximum) and compared to PET/CT which was reconstructed using CT AC and served as standard of reference. Excellent correlations were found for regional uptake values between PET/CT and PET/MRI with TOF (n = 460 segments in 23 patients; r = 0.913; p < 0.0001) with narrow Bland-Altman limits of agreement (-8.5 to +12.6 %). Correlation coefficients were slightly lower between PET/CT and PET/MRI without TOF (n = 460 segments in 23 patients; r = 0.851; p < 0.0001) with broader Bland-Altman limits of agreement (-12.5 to +15.0 %). PET/MRI with and without TOF showed minimal underestimation of tracer uptake (-2.08 and -1.29 %, respectively), compared to PET/CT. Relative myocardial FDG uptake obtained from MR-based attenuation corrected FDG PET is highly comparable to standard CT-based attenuation corrected FDG PET, suggesting interchangeability of both AC techniques. (orig.)

  2. Evaluation of tricuspid annular plane systolic excursion measured with cardiac MRI in children with tetralogy of Fallot.

    Science.gov (United States)

    Soslow, Jonathan H; Usoro, Emem; Wang, Li; Parra, David A

    2016-04-01

    Aneurysmal dilation of the right ventricular outflow tract complicates assessment of right ventricular function in patients with repaired tetralogy of Fallot. Tricuspid annular plane systolic excursion is commonly used to estimate ejection fraction. We hypothesised that tricuspid annular plane systolic excursion measured by cardiac MRI approximates global and segmental right ventricular function, specifically right ventricular sinus ejection fraction, in children with repaired tetralogy of Fallot. Tricuspid annular plane systolic excursion was measured retrospectively on cardiac MRIs in 54 patients with repaired tetralogy of Fallot. Values were compared with right ventricular global, sinus, and infundibular ejection fractions. Tricuspid annular plane systolic excursion was indexed to body surface area, converted into a fractional value, and converted into published paediatric Z-scores. Tricuspid annular plane systolic excursion measurements had good agreement between observers. Right ventricular ejection fraction did not correlate with the absolute or indexed tricuspid annular plane systolic excursion and correlated weakly with fractional tricuspid annular plane systolic excursion (r=0.41 and p=0.002). Segmental right ventricular function did not appreciably improve correlation with any of the tricuspid annular plane systolic excursion measures. Paediatric Z-scores were unable to differentiate patients with normal and abnormal right ventricular function. Tricuspid annular plane systolic excursion measured by cardiac MRI correlates poorly with global and segmental right ventricular ejection fraction in children with repaired tetralogy of Fallot. Tricuspid annular plane systolic excursion is an unreliable approximation of right ventricular function in this patient population.

  3. Development of new anatomy reconstruction software to localize cardiac isochrones to the cardiac surface from the 12 lead ECG.

    Science.gov (United States)

    van Dam, Peter M; Gordon, Jeffrey P; Laks, Michael M; Boyle, Noel G

    2015-01-01

    Non-invasive electrocardiographic imaging (ECGI) of the cardiac muscle can help the pre-procedure planning of the ablation of ventricular arrhythmias by reducing the time to localize the origin. Our non-invasive ECGI system, the cardiac isochrone positioning system (CIPS), requires non-intersecting meshes of the heart, lungs and torso. However, software to reconstruct the meshes of the heart, lungs and torso with the capability to check and prevent these intersections is currently lacking. Consequently the reconstruction of a patient specific model with realistic atrial and ventricular wall thickness and incorporating blood cavities, lungs and torso usually requires additional several days of manual work. Therefore new software was developed that checks and prevents any intersections, and thus enables the use of accurate reconstructed anatomical models within CIPS. In this preliminary study we investigated the accuracy of the created patient specific anatomical models from MRI or CT. During the manual segmentation of the MRI data the boundaries of the relevant tissues are determined. The resulting contour lines are used to automatically morph reference meshes of the heart, lungs or torso to match the boundaries of the morphed tissue. Five patients were included in the study; models of the heart, lungs and torso were reconstructed from standard cardiac MRI images. The accuracy was determined by computing the distance between the segmentation contours and the morphed meshes. The average accuracy of the reconstructed cardiac geometry was within 2mm with respect to the manual segmentation contours on the MRI images. Derived wall volumes and left ventricular wall thickness were within the range reported in literature. For each reconstructed heart model the anatomical heart axis was computed using the automatically determined anatomical landmarks of the left apex and the mitral valve. The accuracy of the reconstructed heart models was well within the accuracy of the used

  4. Respiratory Motion Correction for Compressively Sampled Free Breathing Cardiac MRI Using Smooth l1-Norm Approximation

    Directory of Open Access Journals (Sweden)

    Muhammad Bilal

    2018-01-01

    Full Text Available Transformed domain sparsity of Magnetic Resonance Imaging (MRI has recently been used to reduce the acquisition time in conjunction with compressed sensing (CS theory. Respiratory motion during MR scan results in strong blurring and ghosting artifacts in recovered MR images. To improve the quality of the recovered images, motion needs to be estimated and corrected. In this article, a two-step approach is proposed for the recovery of cardiac MR images in the presence of free breathing motion. In the first step, compressively sampled MR images are recovered by solving an optimization problem using gradient descent algorithm. The L1-norm based regularizer, used in optimization problem, is approximated by a hyperbolic tangent function. In the second step, a block matching algorithm, known as Adaptive Rood Pattern Search (ARPS, is exploited to estimate and correct respiratory motion among the recovered images. The framework is tested for free breathing simulated and in vivo 2D cardiac cine MRI data. Simulation results show improved structural similarity index (SSIM, peak signal-to-noise ratio (PSNR, and mean square error (MSE with different acceleration factors for the proposed method. Experimental results also provide a comparison between k-t FOCUSS with MEMC and the proposed method.

  5. Altered Right Ventricular Kinetic Energy Work Density and Viscous Energy Dissipation in Patients with Pulmonary Arterial Hypertension: A Pilot Study Using 4D Flow MRI.

    Directory of Open Access Journals (Sweden)

    Q Joyce Han

    Full Text Available Right ventricular (RV function has increasingly being recognized as an important predictor for morbidity and mortality in patients with pulmonary arterial hypertension (PAH. The increased RV after-load increase RV work in PAH. We used time-resolved 3D phase contrast MRI (4D flow MRI to derive RV kinetic energy (KE work density and energy loss in the pulmonary artery (PA to better characterize RV work in PAH patients.4D flow and standard cardiac cine images were obtained in ten functional class I/II patients with PAH and nine healthy subjects. For each individual, we calculated the RV KE work density and the amount of viscous dissipation in the PA.PAH patients had alterations in flow patterns in both the RV and the PA compared to healthy subjects. PAH subjects had significantly higher RV KE work density than healthy subjects (94.7±33.7 mJ/mL vs. 61.7±14.8 mJ/mL, p = 0.007 as well as a much greater percent PA energy loss (21.1±6.4% vs. 2.2±1.3%, p = 0.0001 throughout the cardiac cycle. RV KE work density and percent PA energy loss had mild and moderate correlations with RV ejection fraction.This study has quantified two kinetic energy metrics to assess RV function using 4D flow. RV KE work density and PA viscous energy loss not only distinguished healthy subjects from patients, but also provided distinction amongst PAH patients. These metrics hold promise as imaging markers for RV function.

  6. Altered Right Ventricular Kinetic Energy Work Density and Viscous Energy Dissipation in Patients with Pulmonary Arterial Hypertension: A Pilot Study Using 4D Flow MRI.

    Science.gov (United States)

    Han, Q Joyce; Witschey, Walter R T; Fang-Yen, Christopher M; Arkles, Jeffrey S; Barker, Alex J; Forfia, Paul R; Han, Yuchi

    2015-01-01

    Right ventricular (RV) function has increasingly being recognized as an important predictor for morbidity and mortality in patients with pulmonary arterial hypertension (PAH). The increased RV after-load increase RV work in PAH. We used time-resolved 3D phase contrast MRI (4D flow MRI) to derive RV kinetic energy (KE) work density and energy loss in the pulmonary artery (PA) to better characterize RV work in PAH patients. 4D flow and standard cardiac cine images were obtained in ten functional class I/II patients with PAH and nine healthy subjects. For each individual, we calculated the RV KE work density and the amount of viscous dissipation in the PA. PAH patients had alterations in flow patterns in both the RV and the PA compared to healthy subjects. PAH subjects had significantly higher RV KE work density than healthy subjects (94.7±33.7 mJ/mL vs. 61.7±14.8 mJ/mL, p = 0.007) as well as a much greater percent PA energy loss (21.1±6.4% vs. 2.2±1.3%, p = 0.0001) throughout the cardiac cycle. RV KE work density and percent PA energy loss had mild and moderate correlations with RV ejection fraction. This study has quantified two kinetic energy metrics to assess RV function using 4D flow. RV KE work density and PA viscous energy loss not only distinguished healthy subjects from patients, but also provided distinction amongst PAH patients. These metrics hold promise as imaging markers for RV function.

  7. Comparison of diffusion-weighted fMRI and BOLD fMRI responses in a verbal working memory task

    International Nuclear Information System (INIS)

    Aso, Toshihiko; Urayama, Shin-ichi; Fukuyama, Hidenao; Le Bihan, Denis

    2013-01-01

    Diffusion-weighted functional MRI (DfMRI) has been reported to have a different response pattern in the visual cortex than that of BOLD-fMRI. Especially, the DfMRI signal shows a constantly faster response at both onset and offset of the stimulus, suggesting that the DfMRI signal might be more directly linked to neuronal events than the hemodynamic response. However, because the DfMRI response also contains a residual sensitivity to BOLD this hypothesis has been challenged. Using a verbal working memory task we show that the DfMRI time-course features are preserved outside visual cortices, but also less liable to between-subject/between-regional variation than the BOLD response. The overall findings not only support the feasibility of DfMRI as an approach for functional brain imaging, but also strengthen the uniqueness of the DfMRI signal origin. (authors)

  8. Linear Invariant Tensor Interpolation Applied to Cardiac Diffusion Tensor MRI

    Science.gov (United States)

    Gahm, Jin Kyu; Wisniewski, Nicholas; Kindlmann, Gordon; Kung, Geoffrey L.; Klug, William S.; Garfinkel, Alan; Ennis, Daniel B.

    2015-01-01

    Purpose Various methods exist for interpolating diffusion tensor fields, but none of them linearly interpolate tensor shape attributes. Linear interpolation is expected not to introduce spurious changes in tensor shape. Methods Herein we define a new linear invariant (LI) tensor interpolation method that linearly interpolates components of tensor shape (tensor invariants) and recapitulates the interpolated tensor from the linearly interpolated tensor invariants and the eigenvectors of a linearly interpolated tensor. The LI tensor interpolation method is compared to the Euclidean (EU), affine-invariant Riemannian (AI), log-Euclidean (LE) and geodesic-loxodrome (GL) interpolation methods using both a synthetic tensor field and three experimentally measured cardiac DT-MRI datasets. Results EU, AI, and LE introduce significant microstructural bias, which can be avoided through the use of GL or LI. Conclusion GL introduces the least microstructural bias, but LI tensor interpolation performs very similarly and at substantially reduced computational cost. PMID:23286085

  9. Cardiac CT and cardiac MRI - competitive or complementary for nuclear cardiology

    International Nuclear Information System (INIS)

    Moshage, W.

    2004-01-01

    In summary, cardiac computed tomography (CT) and cardiac magnetic resonance (MR) are two different technologies with distinct imaging properties that gain increasing importance in clinical cardiology. Even though images may look similar, the areas of application of CT and MR are quite different. Clinical applications of cardiac CT focus on on-invasive imaging of the coronary arteries. In this respect, the higher spatial resolution of cardiac CT constitutes a significant advantage as compared to MR and clinical results are superior. Clinical applications of cardiac MR, next to morphologic imaging of the heart, are most frequently found in the context of intra-and pericardial masses, complex congenital anomalies, and the assessment of left ventricular function (dobutamine) and perfusion (adenosine) under stress. The evaluation of the size and localization of myocardial necrosis, scars, and fibrosis gains increasing importance, for example in the workup of myocardial infarction, but also myocarditis and cardiomyopathies. In this respect, magnetic resonance imaging partly constitutes an alternative to nuclear medicine methods. Due to the lack of ionizing radiation and a relatively high spatial resolution, an increase of MR diagnostic procedures at the expense of nuclear medicine can be expected. (orig.)

  10. Return to Work in Out-of-Hospital Cardiac Arrest Survivors

    DEFF Research Database (Denmark)

    Kragholm, Kristian; Wissenberg, Mads; Mortensen, Rikke Normark

    2015-01-01

    BACKGROUND: Data on long-term function of out-of-hospital cardiac arrest survivors are sparse. We examined return to work as a proxy of preserved function without major neurologic deficits in survivors. METHODS AND RESULTS: In Denmark, out-of-hospital cardiac arrests have been systematically repo...

  11. Cardiac MRI in restrictive cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, A. [Department of Cardiovascular Radiology, All India Institute of Medical Sciences, Ansari Nagar, Delhi (India); Singh Gulati, G., E-mail: gulatigurpreet@rediffmail.com [Department of Cardiovascular Radiology, All India Institute of Medical Sciences, Ansari Nagar, Delhi (India); Seth, S. [Department of Cardiology, All India Institute of Medical Sciences, Ansari Nagar, Delhi (India); Sharma, S. [Department of Cardiovascular Radiology, All India Institute of Medical Sciences, Ansari Nagar, Delhi (India)

    2012-02-15

    Restrictive cardiomyopathy (RCM) is a specific group of heart muscle disorders characterized by inadequate ventricular relaxation during diastole. This leads to diastolic dysfunction with relative preservation of systolic function. Although short axis systolic function is usually preserved in RCM, the long axis systolic function may be severely impaired. Confirmation of diagnosis and information regarding aetiology, extent of myocardial damage, and response to treatment requires imaging. Importantly, differentiation from constrictive pericarditis (CCP) is needed, as only the latter is managed surgically. Echocardiography is the initial cardiac imaging technique but cannot reliably suggest a tissue diagnosis; although recent advances, especially tissue Doppler imaging and spectral tracking, have improved its ability to differentiate RCM from CCP. Cardiac catheterization is the reference standard, but is invasive, two-dimensional, and does not aid myocardial characterization. Cardiac magnetic resonance (CMR) is a versatile technique providing anatomical, morphological and functional information. In recent years, it has been shown to provide important information regarding disease mechanisms, and also been found useful to guide treatment, assess its outcome and predict patient prognosis. This review describes the CMR features of RCM, appearances in various diseases, its overall role in patient management, and how it compares with other imaging techniques.

  12. Wavelet-space correlation imaging for high-speed MRI without motion monitoring or data segmentation.

    Science.gov (United States)

    Li, Yu; Wang, Hui; Tkach, Jean; Roach, David; Woods, Jason; Dumoulin, Charles

    2015-12-01

    This study aims to (i) develop a new high-speed MRI approach by implementing correlation imaging in wavelet-space, and (ii) demonstrate the ability of wavelet-space correlation imaging to image human anatomy with involuntary or physiological motion. Correlation imaging is a high-speed MRI framework in which image reconstruction relies on quantification of data correlation. The presented work integrates correlation imaging with a wavelet transform technique developed originally in the field of signal and image processing. This provides a new high-speed MRI approach to motion-free data collection without motion monitoring or data segmentation. The new approach, called "wavelet-space correlation imaging", is investigated in brain imaging with involuntary motion and chest imaging with free-breathing. Wavelet-space correlation imaging can exceed the speed limit of conventional parallel imaging methods. Using this approach with high acceleration factors (6 for brain MRI, 16 for cardiac MRI, and 8 for lung MRI), motion-free images can be generated in static brain MRI with involuntary motion and nonsegmented dynamic cardiac/lung MRI with free-breathing. Wavelet-space correlation imaging enables high-speed MRI in the presence of involuntary motion or physiological dynamics without motion monitoring or data segmentation. © 2014 Wiley Periodicals, Inc.

  13. A Combined Random Forests and Active Contour Model Approach for Fully Automatic Segmentation of the Left Atrium in Volumetric MRI

    Directory of Open Access Journals (Sweden)

    Chao Ma

    2017-01-01

    Full Text Available Segmentation of the left atrium (LA from cardiac magnetic resonance imaging (MRI datasets is of great importance for image guided atrial fibrillation ablation, LA fibrosis quantification, and cardiac biophysical modelling. However, automated LA segmentation from cardiac MRI is challenging due to limited image resolution, considerable variability in anatomical structures across subjects, and dynamic motion of the heart. In this work, we propose a combined random forests (RFs and active contour model (ACM approach for fully automatic segmentation of the LA from cardiac volumetric MRI. Specifically, we employ the RFs within an autocontext scheme to effectively integrate contextual and appearance information from multisource images together for LA shape inferring. The inferred shape is then incorporated into a volume-scalable ACM for further improving the segmentation accuracy. We validated the proposed method on the cardiac volumetric MRI datasets from the STACOM 2013 and HVSMR 2016 databases and showed that it outperforms other latest automated LA segmentation methods. Validation metrics, average Dice coefficient (DC and average surface-to-surface distance (S2S, were computed as 0.9227±0.0598 and 1.14±1.205 mm, versus those of 0.6222–0.878 and 1.34–8.72 mm, obtained by other methods, respectively.

  14. Differences in myocardial strain between pectus excavatum patients and healthy subjects assessed by cardiac MRI. A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Lollert, Andre; Staatz, Gundula [Medical Center of the Johannes Gutenberg University Mainz, Department of Diagnostic and Interventional Radiology, Section of Paediatric Radiology, Mainz (Germany); Emrich, Tilman; Eichstaedt, Jakob; Dueber, Christoph; Kreitner, Karl-Friedrich [Medical Center of the Johannes Gutenberg University Mainz, Department of Diagnostic and Interventional Radiology, Mainz (Germany); Kampmann, Christoph; Abu-Tair, Tariq [Medical Center of the Johannes Gutenberg University Mainz, Center for Diseases in Childhood and Adolescence, Division of Paediatric Cardiology and Congenital Heart Diseases, Mainz (Germany); Turial, Salmai [HELIOS Dr. Horst Schmidt Kliniken, Department of Paediatric Surgery and Congenital Malformations, Wiesbaden (Germany)

    2018-03-15

    To evaluate differences in myocardial strain between pectus excavatum (PE) patients and healthy subjects (HS) assessed by cardiac MRI using the feature-tracking algorithm. Cardiac MRI was performed in 14 PE patients and 14 HS (9:5 male to female in each group; age 11-30 years) using a 3T scanner. Post-examination analysis included manual biventricular contouring with volumetry and ejection fraction measurement by two independent radiologists. Dedicated software was used for automated strain assessment. In five of the PE patients, the right ventricular ejection fraction was slightly impaired (40-44 %). PE patients had a significantly higher left ventricular longitudinal strain (P=0.004), mid (P=0.035) and apical (P=0.001) circumferential strain as well as apical circumferential strain rate (P=0.001), mid right ventricular circumferential strain (P=0.008) and strain rate (P=0.035), and apical right ventricular circumferential strain (P=0.012) and strain rate (P=0.044) than HS. The right ventricular longitudinal strain and strain rate did not differ significantly between PE patients and HS. Myocardial strain differs significantly between PE patients and HS. Higher myocardial strain in the mid and apical ventricles of PE patients indicates a compensation mechanism to enhance ventricular output against basal sternal compression. (orig.)

  15. Health complaints among nurses working near MRI scanners-A descriptive pilot study

    International Nuclear Information System (INIS)

    Wilen, Jonna; Vocht, Frank de

    2011-01-01

    A questionnaire-based descriptive pilot study was conducted among all nurses routinely working with MRI in the Northern part of Sweden to provide an indication of the self-reported prevalence of health complaints related to working with MRI systems. Fifty-nine nurses (88% response rate), with on average 8 (±6) years experience with MRI scanning procedures, returned the questionnaire. In total, 9 nurses (15%) reported regularly experiencing at least one of the health complaints (1-5% for specific health complaints) attributed to arise or be aggravated by their presence in the MRI scanning room. Stratification of the results indicated that reporting of adverse symptoms was not related to the level of occupational workload/stress. However, reporting of health complaints was related to the strength of the magnet(s) the nurses worked with, with 57% of symptoms reported by those nurses working with the strongest systems (both 1.5 and 3 T scanners in this population). Although this descriptive study did not include a control population and was based on self-reporting of health complaints, these data indicate that the prevalence of reported health complaints is not related to perceived work load or occupational stress, but does confirm data from other occupational sectors and indicates that the prevalence of adverse health complaints increases with the strength of the MRI system for nurses as well.

  16. Spinal cord motion. Influence of respiration and cardiac cycle

    Energy Technology Data Exchange (ETDEWEB)

    Winklhofer, S. [RWTH Aachen University Hospital (Germany). Dept. of Neuroradiology; University Hospital Zurich (Switzerland). Inst. of Diagnostic and Interventional Radiology; Schoth, F. [RWTH Aachen University Hospital (Germany). Dept. of Diagnostic Radiology; Stolzmann, P. [University Hospital Zurich (Switzerland). Inst. of Diagnostic and Interventional Radiology; Krings, T. [Toronto Western Hospital, ON (Canada). Div. of Neuroradiology; Mull, M.; Wiesmann, M. [RWTH Aachen University Hospital (Germany). Dept. of Neuroradiology; Stracke, C.P. [RWTH Aachen University Hospital (Germany). Dept. of Neuroradiology; Alfried-Krupp-Hospital, Essen (Germany). Dept. of Neuroradiology

    2014-11-15

    To assess physiological spinal cord motion during the cardiac cycle compared with the influence of respiration based on magnetic resonance imaging (MRI) measurements. Anterior-posterior spinal cord motion within the spinal canal was assessed in 16 healthy volunteers (median age, 25 years) by cardiac-triggered and cardiac-gated gradient echo pulse sequence MRI. Image acquisition was performed during breath-holding, normal breathing, and forced breathing. Normal spinal cord motion values were computed using descriptive statistics. Breathing-dependent differences were assessed using the Wilcoxon signed-rank test and compared with the cardiac-based cord motion. A normal value table was set up for the spinal cord motion of each vertebral cervico-thoracic-lumbar segment. Significant differences in cord motion were found between cardiac-based motion while breath-holding and the two breathing modalities (P < 0.01 each). Spinal cord motion was found to be highest during forced breathing, with a maximum in the lower cervical spinal segments (C5; mean, 2.1 mm ± 1.17). Image acquisition during breath-holding revealed the lowest motion. MRI permits the demonstration and evaluation of cardiac and respiration-dependent spinal cord motion within the spinal canal from the cervical to lumbar segments. Breathing conditions have a considerably greater impact than cardiac activity on spinal cord motion.

  17. Spinal cord motion. Influence of respiration and cardiac cycle

    International Nuclear Information System (INIS)

    Winklhofer, S.; University Hospital Zurich; Schoth, F.; Stolzmann, P.; Krings, T.; Mull, M.; Wiesmann, M.; Stracke, C.P.; Alfried-Krupp-Hospital, Essen

    2014-01-01

    To assess physiological spinal cord motion during the cardiac cycle compared with the influence of respiration based on magnetic resonance imaging (MRI) measurements. Anterior-posterior spinal cord motion within the spinal canal was assessed in 16 healthy volunteers (median age, 25 years) by cardiac-triggered and cardiac-gated gradient echo pulse sequence MRI. Image acquisition was performed during breath-holding, normal breathing, and forced breathing. Normal spinal cord motion values were computed using descriptive statistics. Breathing-dependent differences were assessed using the Wilcoxon signed-rank test and compared with the cardiac-based cord motion. A normal value table was set up for the spinal cord motion of each vertebral cervico-thoracic-lumbar segment. Significant differences in cord motion were found between cardiac-based motion while breath-holding and the two breathing modalities (P < 0.01 each). Spinal cord motion was found to be highest during forced breathing, with a maximum in the lower cervical spinal segments (C5; mean, 2.1 mm ± 1.17). Image acquisition during breath-holding revealed the lowest motion. MRI permits the demonstration and evaluation of cardiac and respiration-dependent spinal cord motion within the spinal canal from the cervical to lumbar segments. Breathing conditions have a considerably greater impact than cardiac activity on spinal cord motion.

  18. Cardiac Intensive Care Unit Management of Patients After Cardiac Arrest: Now the Real Work Begins.

    Science.gov (United States)

    Randhawa, Varinder K; Grunau, Brian E; Debicki, Derek B; Zhou, Jian; Hegazy, Ahmed F; McPherson, Terry; Nagpal, A Dave

    2018-02-01

    Survival with a good quality of life after cardiac arrest continues to be abysmal. Coordinated resuscitative care does not end with the effective return of spontaneous circulation (ROSC)-in fact, quite the contrary is true. Along with identifying and appropriately treating the precipitating cause, various components of the post-cardiac arrest syndrome also require diligent observation and management, including post-cardiac arrest neurologic injury and myocardial dysfunction, systemic ischemia-reperfusion phenomenon with potential consequent multiorgan failure, and the various sequelae of critical illness. There is growing evidence that an early invasive approach to coronary reperfusion with percutaneous coronary intervention, together with active targeted temperature management and optimization of hemodynamic, ventilator, and metabolic parameters, may improve survival and neurologic outcomes in cardiac arrest survivors. Neuroprognostication is complex, as are survivorship issues and long-term rehabilitation. Our paramedics, emergency physicians, and resuscitation specialists are all to be congratulated for ever-increasing success with ROSC… but now the real work begins. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  19. Can cardiovascular MRI be used to more definitively characterize cardiac masses initially identified using echocardiography?

    Science.gov (United States)

    Rathi, Vikas K; Czajka, Anna T; Thompson, Diane V; Doyle, Mark; Tewatia, Tarun; Yamrozik, June; Williams, Ronald B; Biederman, Robert W W

    2018-05-01

    In diagnosing cardiac and paracardiac masses, cardiac MRI (CMR) has gained acceptance as the gold standard. CMR has been observed to be superior to echocardiography in characterizing soft-tissue structures and, specifically, in classifying cardiac masses. The aim of our study was to evaluate the association between mortality and cardiac or paracardiac masses initially identified by echocardiography (ECHO) and confirmed by CMR. Between January 2002 and August 2007, a total of 158 patients underwent both ECHO and CMR for the evaluation of cardiac masses that were equivocal or undefined by ECHO. The primary study endpoints were 5-year all-cause mortality and 5-year cardiac mortality. Causes of death as of April 1, 2015 were obtained from medical records or the National Death Index. Patients were analyzed according to mass type determined by CMR using the Kruskal-Wallis test, Kaplan-Meier curves, and the log-rank test. Over a mean duration of follow-up of 10.4 ± 2.9 years (range: 0.01-12 years) post-CMR, the overall all-cause mortality rate was 25.9% (41/158). Median age at death was 76 years and there were 21 females (51.2%). Mortality rates in the different classifications of cardiac masses by CMR were as follows: 20% (1/5) in patients with a Nondiagnostic CMR; 20% (1/5) in Other Diagnoses; 17.9% (7/39) in No Masses (includes Normal Anatomical Variants); 16.7% (3/18) in Benign Masses; 23.8% (15/63) in Fat; 50% (5/10) in Thrombus; and 61.5% (8/13) in Malignant Mass. The mean survival time in patients with No Mass (n = 39) was not significantly longer than patients with any type of cardiac mass (n = 114) (P = .16). No significant difference was found in age at death between patients when grouped by CMR classification (P = .40). However, among CMR-confirmed masses, there were some significant differences by mass classification type (P = .006). During the follow-up period, 26% (41/158) of patients died and 22% (9/41) of the deaths were cardiovascular

  20. Defining active sacroiliitis on MRI for classification of axial spondyloarthritis: update by the ASAS MRI working group

    DEFF Research Database (Denmark)

    Lambert, Robert G W; Bakker, Pauline A C; van der Heijde, Désirée

    2016-01-01

    OBJECTIVES: To review and update the existing definition of a positive MRI for classification of axial spondyloarthritis (SpA). METHODS: The Assessment in SpondyloArthritis International Society (ASAS) MRI working group conducted a consensus exercise to review the definition of a positive MRI...... for inclusion in the ASAS classification criteria of axial SpA. Existing definitions and new data relevant to the MRI diagnosis and classification of sacroiliitis and spondylitis in axial SpA, published since the ASAS definition first appeared in print in 2009, were reviewed and discussed. The precise wording...... of the existing definition was examined in detail and the data and a draft proposal were presented to and voted on by the ASAS membership. RESULTS: The clear presence of bone marrow oedema on MRI in subchondral bone is still considered to be the defining observation that determines the presence of active...

  1. Physical inactivity at leisure and work: a 12-month study of cardiac patients.

    Science.gov (United States)

    Rogerson, Michelle C; Murphy, Barbara M; Le Grande, Michael R; Worcester, Marian U C

    2013-01-01

    Physical inactivity has been identified as a distinct health risk. However, little is known about how this can vary at leisure and work in cardiac patients. The aim of this study was to examine the prevalence and predictors of inactivity during leisure and work in the 12 months following a cardiac event in Australian cardiac patients. A total of 346 patients consecutively admitted to hospital with acute coronary syndrome or to undergo coronary artery bypass graft surgery were interviewed in hospital, and 4 and 12 months later. Leisure and occupational physical activity was measured using the Stanford Brief Activity Survey. Sociodemographic, psychosocial, and clinical data were also collected. The prevalence of leisure-time physical inactivity declined over time, with 52% inactive preevent and 29% inactive at 12 months. Approximately 50% of participants were physically inactive in their work, regardless of whether this was measured before or after the cardiac event. Logistic regression revealed that the significant predictors of leisure-time physical inactivity at 12 months were non-home ownership (OR = 2.19; P = .007) and physical inactivity in leisure-time prior to the event (OR = 2.44; P = .001). The significant predictors of occupational physical inactivity at 12 months were white-collar occupation (OR = 3.10; P physical inactivity at work prior to the event (OR = 12.99; P physical inactivity, socioeconomic, and clinical factors predicted both leisure and work inactivity after an acute cardiac event. Effective interventions could be designed and implemented to target those most at risk of being physically inactive at work or leisure.

  2. Comprehensive 4-stage categorization of bicuspid aortic valve leaflet morphology by cardiac MRI in 386 patients.

    Science.gov (United States)

    Murphy, I G; Collins, J; Powell, A; Markl, M; McCarthy, P; Malaisrie, S C; Carr, J C; Barker, A J

    2017-08-01

    Bicuspid aortic valve (BAV) disease is heterogeneous and related to valve dysfunction and aortopathy. Appropriate follow up and surveillance of patients with BAV may depend on correct phenotypic categorization. There are multiple classification schemes, however a need exists to comprehensively capture commissure fusion, leaflet asymmetry, and valve orifice orientation. Our aim was to develop a BAV classification scheme for use at MRI to ascertain the frequency of different phenotypes and the consistency of BAV classification. The BAV classification scheme builds on the Sievers surgical BAV classification, adding valve orifice orientation, partial leaflet fusion and leaflet asymmetry. A single observer successfully applied this classification to 386 of 398 Cardiac MRI studies. Repeatability of categorization was ascertained with intraobserver and interobserver kappa scores. Sensitivity and specificity of MRI findings was determined from operative reports, where available. Fusion of the right and left leaflets accounted for over half of all cases. Partial leaflet fusion was seen in 46% of patients. Good interobserver agreement was seen for orientation of the valve opening (κ = 0.90), type (κ = 0.72) and presence of partial fusion (κ = 0.83, p < 0.0001). Retrospective review of operative notes showed sensitivity and specificity for orientation (90, 93%) and for Sievers type (73, 87%). The proposed BAV classification schema was assessed by MRI for its reliability to classify valve morphology in addition to illustrating the wide heterogeneity of leaflet size, orifice orientation, and commissural fusion. The classification may be helpful in further understanding the relationship between valve morphology, flow derangement and aortopathy.

  3. Imaging technique and current status of valvular heart disease using cardiac MRI; Untersuchungstechniken und Stellenwert der MRT bei der Diagnostik von Herzklappenerkrankungen

    Energy Technology Data Exchange (ETDEWEB)

    Lotz, J.; Sohns, J.M. [Universitaetsmedizin Goettingen, Georg-August-Universitaet, Institut fuer Diagnostische und Interventionelle Radiologie, Goettingen (Germany)

    2013-10-15

    The main indications for cardiac magnetic resonance imaging (MRI) in the evaluation of valvular heart disease are pathologies of the aortic and pulmonary valve. For mitral and tricuspid valve pathologies MRI is not the first line modality as these are usually well visualized by echocardiography. The advantages of MRI in valvular heart disease are a high reliability in the evaluation of ventricular volumes and function as well as the assessment of the perivalvular arterial or atrial structures. This reliability and the limitless access to any imaging plane partially compensates for the lower temporal and spatial resolution in comparison to echocardiography. In patients with congenital heart disease, cardiac MRI is established as a valuable diagnostic tool in daily clinical management, especially for the evaluation of pulmonary valve defects. Nevertheless, echocardiography remains the first-line diagnostic imaging tool for the foreseeable future. (orig.) [German] Die Untersuchung der Herzklappen in der MRT umfasst derzeit v. a. die Aorten- und Pulmonalisklappe. Pathologien der atrioventrikulaeren Klappen bilden demgegenueber nur selten die zentrale Fragestellung einer kardialen MRT-Untersuchung, da diese normalerweise einer echokardiographischen Untersuchung gut zugaenglich sind. Die Staerke der MRT ist die hohe Zuverlaessigkeit, mit der neben der Klappenmorphologie und -funktion die Funktionsparameter des jeweiligen Ventrikels und die Morphologie der nachgeschalteten Arterien bestimmt werden koennen. Dadurch kann die MRT die prinzipielle Schwaeche in der Orts- und Zeitaufloesung gegenueber der Echokardiographie teilweise kompensieren. Bei Patienten mit kongenitalen Herzvitien ist die MRT-basierte Klappendiagnostik fester Bestandteil des klinischen Managements. Das gilt besonders fuer die Evaluation der Pulmonalisklappe. Die Echokardiographie bleibt absehbar die Modalitaet der ersten Wahl fuer die Klappendiagnostik am Herzen. (orig.)

  4. Transient health symptoms of MRI staff working with 1.5 and 3.0 Tesla scanners in the UK

    Energy Technology Data Exchange (ETDEWEB)

    De Vocht, Frank [University of Bristol, School of Social and Community Medicine, Bristol (United Kingdom); Batistatou, Evridiki [University of Manchester, Centre for Occupational and Environmental Health, Manchester (United Kingdom); Moelter, Anna [Colorado State University, Department of Environmental and Radiological Health Sciences, Fort Collins, CO (United States); Kromhout, Hans; Schaap, Kristel [Utrecht University, Institute for Risk Assessment Sciences (IRAS), Utrecht (Netherlands); Van Tongeren, Martie [Institute of Occupational Medicine, Centre for Human Exposure Science, Edinburgh (United Kingdom); Crozier, Stuart [University of Queensland, School of Information Technology and Electrical Engineering, Brisbane (Australia); Gowland, Penny [University of Nottingham, Sir Peter Mansfield Magnetic Resonance Centre, Nottingham (United Kingdom); Keevil, Stephen [Guy' s and St Thomas' NHS Foundation Trust, Department of Medical Physics, London (United Kingdom); King' s College London, Department of Biomedical Engineering, London (United Kingdom)

    2015-09-15

    Recent studies have consistently shown that amongst staff working with MRI, transient symptoms directly attributable to the MRI system including dizziness, nausea, tinnitus, and concentration problems are reported. This study assessed symptom prevalence and incidence in radiographers and other staff working with MRI in healthcare in the UK. One hundred and four volunteer staff from eight sites completed a questionnaire and kept a diary to obtain information on subjective symptoms and work practices, and wore a magnetic field dosimeter during one to three randomly selected working days. Incidence of MRI-related symptoms was obtained for all shifts and prevalence of MRI-related and reference symptoms was associated to explanatory factors using ordinal regression. Incident symptoms related to working with MRI were reported in 4 % of shifts. Prevalence of MRI-related, but not reference symptoms were associated with number of hours per week working with MRI, shift length, and stress, but not with magnetic field strength (1.5 and 3 T) or measured magnetic field exposure. Reporting of prevalent symptoms was associated with longer duration of working in MRI departments, but not with measured field strength of exposure. Other factors related to organisation and stress seem to contribute to increased reporting of MRI-related symptoms. (orig.)

  5. Transient health symptoms of MRI staff working with 1.5 and 3.0 Tesla scanners in the UK

    International Nuclear Information System (INIS)

    De Vocht, Frank; Batistatou, Evridiki; Moelter, Anna; Kromhout, Hans; Schaap, Kristel; Van Tongeren, Martie; Crozier, Stuart; Gowland, Penny; Keevil, Stephen

    2015-01-01

    Recent studies have consistently shown that amongst staff working with MRI, transient symptoms directly attributable to the MRI system including dizziness, nausea, tinnitus, and concentration problems are reported. This study assessed symptom prevalence and incidence in radiographers and other staff working with MRI in healthcare in the UK. One hundred and four volunteer staff from eight sites completed a questionnaire and kept a diary to obtain information on subjective symptoms and work practices, and wore a magnetic field dosimeter during one to three randomly selected working days. Incidence of MRI-related symptoms was obtained for all shifts and prevalence of MRI-related and reference symptoms was associated to explanatory factors using ordinal regression. Incident symptoms related to working with MRI were reported in 4 % of shifts. Prevalence of MRI-related, but not reference symptoms were associated with number of hours per week working with MRI, shift length, and stress, but not with magnetic field strength (1.5 and 3 T) or measured magnetic field exposure. Reporting of prevalent symptoms was associated with longer duration of working in MRI departments, but not with measured field strength of exposure. Other factors related to organisation and stress seem to contribute to increased reporting of MRI-related symptoms. (orig.)

  6. Increased working memory related fMRI signal in children following Tick Borne Encephalitis.

    Science.gov (United States)

    Henrik, Ullman; Åsa, Fowler; Ronny, Wickström

    2016-01-01

    Tick Borne Encephalitis (TBE) is a viral infection in the central nervous system endemic in Europe and Asia. While pediatric infection may carry a lower risk for serious neurological sequelae compared to adults, a large proportion of children experience long term cognitive problems, most markedly decreased working memory capacity. We explored whether task related functional magnetic resonance imaging (MRI) and diffusion tensor imaging (DTI) could reveal a biological correlate of status-post TBE in children. We examined 11 serologically verified pediatric TBE patients with central nervous system involvement with 55 healthy controls with working memory tests and MRI. The TBE patients showed a prominent deficit in working memory capacity and an increased task related functional MRI signal in working memory related cortical areas during a spatial working memory task performed without sedation. No diffusion differences could be found with DTI, in line with the reported paucity of anatomical abnormalities. This study is the first to demonstrate functional MRI abnormalities in TBE patients that bears similarity to other patient groups with diffuse neuronal damage. Copyright © 2015 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.

  7. Clinical impact of left ventricular eccentricity index using cardiac MRI in assessment of right ventricular hemodynamics and myocardial fibrosis in congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Yamasaki, Yuzo; Kamitani, Takeshi; Yamanouchi, Torahiko; Honda, Hiroshi [Kyushu University, Departments of Clinical Radiology, Graduate School of Medical Sciences, Fukuoka (Japan); Nagao, Michinobu; Kawanami, Satoshi [Kyushu University, Molecular Imaging and Diagnosis, Graduate School of Medical Sciences, Fukuoka (Japan); Yamamura, Kenichiro [Kyushu University, Pediatrics, Graduate School of Medical Sciences, Fukuoka (Japan); Sakamoto, Ichiro [Kyushu University, Cardiovascular Medicine, Graduate School of Medical Sciences, Fukuoka (Japan); Yabuuchi, Hidetake [Kyushu University, Health SciencesGraduate School of Medical Sciences, Fukuoka (Japan)

    2016-10-15

    To investigate the utility of eccentricity index (EI) using cardiac cine MRI for the assessment of right ventricular (RV) hemodynamics in congenital heart disease (CHD). Fifty-five patients with CHD (32 women; mean age, 40.7 ± 20.9 years) underwent both cardiac MRI and right heart catheterization. EI was defined as the ratio of the distance between the anterior-posterior wall and the septal-lateral wall measured in the short-axis of mid-ventricular cine MRI. Correlations between EIs and RV hemodynamic parameters were analyzed. EIs were compared between patients with and without late gadolinium enhancement (LGE). A strong correlation between mean pulmonary artery pressure (PAP) and systolic EI (r = 0.81, p < 0.0001) and a moderate negative correlation between diastolic EI and RV ejection fraction (EF) (r = -0.62, p < 0.0001) were observed. Receiver operating characteristic analysis revealed optimal EI thresholds for detecting patients with mean PAP ≥40 mmHg with C-statistics of 0.90 and patients with RVEF <40 % with C-statistics of 0.78. Systolic EIs were significantly greater for patients with LGE (1.45 ± 0.05) than for those without LGE (1.15 ± 0.07; p < 0.001). EI offers a simple, comprehensive index that can predict pulmonary hypertension and RV dysfunction in CHD. (orig.)

  8. Cardiac magnetic resonance imaging in evaluation of anatomical structure and function of the ventricles

    International Nuclear Information System (INIS)

    Suzuki, Jun-ichi; Usui, Masahiro; Takenaka, Katsu

    1990-01-01

    Cardiac magnetic resonance imaging (MRI) is being widely employed for evaluation of cardiovascular anatomies and functions. However, the indications for cardiac MRI to obtain information which cannot be obtained using other conventional methods have not yet been determined. To demonstrate the usefulness of MRI in delineating the apex of the left ventricle and free wall of the right ventricle, end-diastolic short axis MRI images were obtained in 20 patients with apical hypertrophy and in 9 normal volunteers. To compare the accuracy of estimations of left ventricular volumes obtained using the modified Simpson's method of MRI with that using the MRI area length method, 19 patients, in whom left ventriculography had been performed, were studied. The apex of the left ventricle was evaluated circumferentially and distribution of hypertrophied muscles was defined. Sixty-five percent of the length of the right ventricular free wall was clearly delineated. Correlation coefficients of the ejection fraction between MRI and angiography were 0.85 with the modified Simpson's method of MRI, and 0.62 with the area length method of MRI. Three themes were chosen to demonstrate good clinical indications for cardiac MRI. (author)

  9. Multidetector CT and MRI of ostial atresia of the coronary sinus, associated collateral venous pathways and cardiac anomalies

    International Nuclear Information System (INIS)

    Shum, J.S.F.; Kim, S.M.; Choe, Y.H.

    2012-01-01

    Aim: To analyse the multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) findings in patients with atresia of the coronary sinus orifice (CSA). Materials and methods: MDCT findings of 15 consecutive adult patients with CSAs were retrospectively analysed. The patients underwent contrast-enhanced electrocardiography-gated MDCT (n = 13) or both CT and MRI (n = 2). Results: The mean size of the coronary sinus (CS) was 14.2 mm (range 5.5–24 mm) and 11 patients (73.3%) showed CS dilatation (diameter ≥12 mm). The mean length of the atretic CS segment was 2.9 mm (range 0–8 mm). Different forms of venous collateral pathways were observed in the CSA patients. Nine (60%) of the 15 CSA patients had communication between the right atrium (RA; n = 6) or LA (n = 5) and CS via intraseptal veins; six patients (40%) had persistent left superior caval veins; communications were also observed between the CS and RA (n = 4) or LA (n = 4); two patients had collateral venous pathways between dilated cardiac veins with RA; two patients had unroofing of the CS as outlet channels. Nine patients (60%) had cardiac anomalies: coronary artery fistula to the pulmonary artery (n = 6) or left ventricular base and CS (n = 1), atrial septal defects (n = 2), and a ventricular septal defect (n = 1). Conclusion: CSA patients have venous collateral pathways and a high incidence of associated cardiovascular anomalies such as coronary artery fistulae and atrial septal defects.

  10. Simultaneous detection of landmarks and key-frame in cardiac perfusion MRI using a joint spatial-temporal context model

    Science.gov (United States)

    Lu, Xiaoguang; Xue, Hui; Jolly, Marie-Pierre; Guetter, Christoph; Kellman, Peter; Hsu, Li-Yueh; Arai, Andrew; Zuehlsdorff, Sven; Littmann, Arne; Georgescu, Bogdan; Guehring, Jens

    2011-03-01

    Cardiac perfusion magnetic resonance imaging (MRI) has proven clinical significance in diagnosis of heart diseases. However, analysis of perfusion data is time-consuming, where automatic detection of anatomic landmarks and key-frames from perfusion MR sequences is helpful for anchoring structures and functional analysis of the heart, leading toward fully automated perfusion analysis. Learning-based object detection methods have demonstrated their capabilities to handle large variations of the object by exploring a local region, i.e., context. Conventional 2D approaches take into account spatial context only. Temporal signals in perfusion data present a strong cue for anchoring. We propose a joint context model to encode both spatial and temporal evidence. In addition, our spatial context is constructed not only based on the landmark of interest, but also the landmarks that are correlated in the neighboring anatomies. A discriminative model is learned through a probabilistic boosting tree. A marginal space learning strategy is applied to efficiently learn and search in a high dimensional parameter space. A fully automatic system is developed to simultaneously detect anatomic landmarks and key frames in both RV and LV from perfusion sequences. The proposed approach was evaluated on a database of 373 cardiac perfusion MRI sequences from 77 patients. Experimental results of a 4-fold cross validation show superior landmark detection accuracies of the proposed joint spatial-temporal approach to the 2D approach that is based on spatial context only. The key-frame identification results are promising.

  11. Left ventricular diastolic function in type 2 diabetes mellitus and the association with coronary artery calcium score: a cardiac MRI study.

    Science.gov (United States)

    Graça, Bruno; Donato, Paulo; Ferreira, Maria João; Castelo-Branco, Miguel; Caseiro-Alves, Filipe

    2014-06-01

    The purpose of this study was to compare cardiac MRI-derived parameters of left ventricular (LV) diastolic function between uncomplicated type 2 diabetes mellitus (DM2) and normoglycemic control subjects and to evaluate whether these parameters of LV diastolic function are related to coronary atherosclerosis. We prospectively studied 41 subjects with DM2 and 21 normoglycemic control subjects (30 women and 32 men; mean age, 57.2 ± 7.1 [SD] years) with no evidence of overt cardiovascular disease. We used cardiac MRI to measure LV volumes, LV peak filling rate (PFR), and transmitral flow and CT to determine coronary artery calcium scores. Absolute values of the peak filling rate (PFR) were significantly lower in DM2 patients than in control subjects (mean ± SD, 293.2 ± 51.7 vs 375.7 ± 102.8 mL/s, respectively; p DM2 patients compared with control subjects. DM2 patients with coronary artery calcification showed a lower PFR normalized to stroke volume (SV) (mean ± SD, 4.4 ± 1.0 vs 5.3 ± 1.4, respectively; p = 0.038) and lower mitral peak E velocities (40.1 ± 11.3 vs 48.0 ± 7.3 cm/s; p = 0.024) than DM2 patients without coronary calcification. PFR normalized to SV was independently associated with the presence of coronary artery calcification (β = -1.5, p = 0.005). DM2 decreases cardiovascular MRI-derived parameters of LV diastolic function. Patients with DM2 and coronary atherosclerosis show a more impaired LV diastolic function than patients without coronary atherosclerosis.

  12. 1998 survey of cardiac pacing in South Africa report of the working ...

    African Journals Online (AJOL)

    1998 survey of cardiac pacing in South Africa report of the working group on registries of the Cardiac Arrhythmia Society of South Africa (CASSA). RN Scott Millar. Abstract. No Abstract. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · AJOL African Journals ...

  13. Cardiac Catheterization (For Parents)

    Science.gov (United States)

    ... cases, the doctor might call for a cardiac magnetic resonance imaging (MRI) scan or a CAT scan . ... first couple of days. This means no heavy lifting (more than 10 pounds) and no sports. After ...

  14. Cardiac Catheterization (For Teens)

    Science.gov (United States)

    ... doctor may also call for a cardiac MRI (magnetic resonance imaging) scan or a CT (computerized tomography) ... first couple of days. This means no heavy lifting (nothing over 10 pounds) and no sports. After ...

  15. Automated Segmentation of Cardiac Magnetic Resonance Images

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Nilsson, Jens Chr.; Grønning, Bjørn A.

    2001-01-01

    Magnetic resonance imaging (MRI) has been shown to be an accurate and precise technique to assess cardiac volumes and function in a non-invasive manner and is generally considered to be the current gold-standard for cardiac imaging [1]. Measurement of ventricular volumes, muscle mass and function...

  16. Calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated 15O-water PET/CT: 5D-PET.

    Science.gov (United States)

    Nordström, Jonny; Kero, Tanja; Harms, Hendrik Johannes; Widström, Charles; Flachskampf, Frank A; Sörensen, Jens; Lubberink, Mark

    2017-11-14

    Quantitative measurement of myocardial blood flow (MBF) is of increasing interest in the clinical assessment of patients with suspected coronary artery disease (CAD). 15 O-water positron emission tomography (PET) is considered the gold standard for non-invasive MBF measurements. However, calculation of left ventricular (LV) volumes and ejection fraction (EF) is not possible from standard 15 O-water uptake images. The purpose of the present work was to investigate the possibility of calculating LV volumes and LVEF from cardiac-gated parametric blood volume (V B ) 15 O-water images and from first pass (FP) images. Sixteen patients with mitral or aortic regurgitation underwent an eight-gate dynamic cardiac-gated 15 O-water PET/CT scan and cardiac MRI. V B and FP images were generated for each gate. Calculations of end-systolic volume (ESV), end-diastolic volume (EDV), stroke volume (SV) and LVEF were performed with automatic segmentation of V B and FP images, using commercially available software. LV volumes and LVEF were calculated with surface-, count-, and volume-based methods, and the results were compared with gold standard MRI. Using V B images, high correlations between PET and MRI ESV (r = 0.89, p  0.86, p dynamic 15 O-water PET is feasible and shows good correlation with MRI. However, the analysis method is laborious, and future work is needed for more automation to make the method more easily applicable in a clinical setting.

  17. Improved Imaging in Cardiac Patients: echocardiography and CT-coronary angiography

    NARCIS (Netherlands)

    T.W. Galema (Tjebbe)

    2010-01-01

    textabstractDiff erent non-invasive imaging modalities are used for to assess cardiac anatomy and function. Echocardiography and MRI allow assessment of cardiac structures and function of the cardiac chambers and valves as well as perfusion of the left ventricular wall while CT-angiography in

  18. Myocardial delayed contrast enhancement in patients with arterial hypertension: Initial results of cardiac MRI

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, Kjel [Institute of Diagnostic Radiology, University Hospital Duesseldorf, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: kjel_andersen@web.de; Hennersdorf, Marcus [Department of Cardiology, University Hospital Duesseldorf, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: hennersdorf@med.uni-duesseldorf.de; Cohnen, Mathias [Institute of Diagnostic Radiology, University Hospital Duesseldorf, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: cohnen@med.uni-duesseldorf.de; Blondin, Dirk [Institute of Diagnostic Radiology, University Hospital Duesseldorf, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: blondin@med.uni-duesseldorf.de; Moedder, Ulrich [Institute of Diagnostic Radiology, University Hospital Duesseldorf, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: moedder@uni-duesseldorf.de; Poll, Ludger W. [Institute of Diagnostic Radiology, University Hospital Duesseldorf, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: poll@gmx.de

    2009-07-15

    Purpose: In arterial hypertension left ventricular hypertrophy comprises myocyte hypertrophy, interstitial fibrosis and structural alterations of the coronary microcirculation. MRI enables the detection of myocardial fibrosis, infarction and scar tissue by delayed enhancement (DE) after contrast media application. Aim of this study was to investigate patients with arterial hypertension but without known coronary disease or previous myocardial infarction to detect areas of DE. Methods and material: Twenty patients with arterial hypertension with clinical symptoms of myocardial ischemia, but without history of myocardial infarction and normal coronary arteries during coronary angiography were investigated on a 1.0 T superconducting magnet (Gyroscan T10-NT, Intera Release 8.0, Philips). Fast gradient-echo cine sequences and T2-weighted STIR-sequences were acquired. Fifteen minutes after injection of Gadobenate dimeglumine inversion recovery gradient-echo sequences were performed for detection of myocardial DE. Presence or absence of DE on MRI was correlated with clinical data and the results of echocardiography and electrocardiography, respectively. Results: Nine of 20 patients showed DE in the interventricular septum and the anteroseptal left ventricular wall. In 6 patients, DE was localized intramurally and in 3 patients subendocardially. There was a significant correlation between myocardial DE and ST-segment depressions during exercise and between DE and left-ventricular enddiastolic pressure. Patients with intermittent atrial fibrillation showed a myocardial DE more often than patients without atrial fibrillation. Conclusion: In our series, 45% of patients with arterial hypertension showed DE on cardiac MRI. In this clinical setting, delayed enhancement may be due to coronary microangiopathy. The more intramurally localization of DE, however, rather indicates myocardial interstitial fibrosis.

  19. Myocardial delayed contrast enhancement in patients with arterial hypertension: Initial results of cardiac MRI

    International Nuclear Information System (INIS)

    Andersen, Kjel; Hennersdorf, Marcus; Cohnen, Mathias; Blondin, Dirk; Moedder, Ulrich; Poll, Ludger W.

    2009-01-01

    Purpose: In arterial hypertension left ventricular hypertrophy comprises myocyte hypertrophy, interstitial fibrosis and structural alterations of the coronary microcirculation. MRI enables the detection of myocardial fibrosis, infarction and scar tissue by delayed enhancement (DE) after contrast media application. Aim of this study was to investigate patients with arterial hypertension but without known coronary disease or previous myocardial infarction to detect areas of DE. Methods and material: Twenty patients with arterial hypertension with clinical symptoms of myocardial ischemia, but without history of myocardial infarction and normal coronary arteries during coronary angiography were investigated on a 1.0 T superconducting magnet (Gyroscan T10-NT, Intera Release 8.0, Philips). Fast gradient-echo cine sequences and T2-weighted STIR-sequences were acquired. Fifteen minutes after injection of Gadobenate dimeglumine inversion recovery gradient-echo sequences were performed for detection of myocardial DE. Presence or absence of DE on MRI was correlated with clinical data and the results of echocardiography and electrocardiography, respectively. Results: Nine of 20 patients showed DE in the interventricular septum and the anteroseptal left ventricular wall. In 6 patients, DE was localized intramurally and in 3 patients subendocardially. There was a significant correlation between myocardial DE and ST-segment depressions during exercise and between DE and left-ventricular enddiastolic pressure. Patients with intermittent atrial fibrillation showed a myocardial DE more often than patients without atrial fibrillation. Conclusion: In our series, 45% of patients with arterial hypertension showed DE on cardiac MRI. In this clinical setting, delayed enhancement may be due to coronary microangiopathy. The more intramurally localization of DE, however, rather indicates myocardial interstitial fibrosis.

  20. Cardiac imaging in adults

    International Nuclear Information System (INIS)

    Jaffe, C.C.

    1987-01-01

    This book approaches adult cardiac disease from the correlative imaging perspective. It includes chest X-rays and angiographs, 2-dimensional echocardiograms with explanatory diagrams for clarity, plus details on digital radiology, nuclear medicine techniques, CT and MRI. It also covers the normal heart, valvular heart disease, myocardial disease, pericardial disease, bacterial endocarditis, aortic aneurysm, cardiac tumors, and congenital heart disease of the adult. It points out those aspects where one imaging technique has significant superiority

  1. Cardiac imaging in adults

    Energy Technology Data Exchange (ETDEWEB)

    Jaffe, C.C.

    1987-01-01

    This book approaches adult cardiac disease from the correlative imaging perspective. It includes chest X-rays and angiographs, 2-dimensional echocardiograms with explanatory diagrams for clarity, plus details on digital radiology, nuclear medicine techniques, CT and MRI. It also covers the normal heart, valvular heart disease, myocardial disease, pericardial disease, bacterial endocarditis, aortic aneurysm, cardiac tumors, and congenital heart disease of the adult. It points out those aspects where one imaging technique has significant superiority.

  2. Efficient preloading of the ventricles by a properly timed atrial contraction underlies stroke work improvement in the acute response to cardiac resynchronization therapy

    Science.gov (United States)

    Hu, Yuxuan; Gurev, Viatcheslav; Constantino, Jason; Trayanova, Natalia

    2013-01-01

    Background The acute response to cardiac resynchronization therapy (CRT) has been shown to be due to three mechanisms: resynchronization of ventricular contraction, efficient preloading of the ventricles by a properly timed atrial contraction, and mitral regurgitation reduction. However, the contribution of each of the three mechanisms to the acute response of CRT, specifically stroke work improvement, has not been quantified. Objective The goal of this study was to use an MRI-based anatomically accurate 3D model of failing canine ventricular electromechanics to quantify the contribution of each of the three mechanisms to stroke work improvement and identify the predominant mechanisms. Methods An MRI-based electromechanical model of the failing canine ventricles assembled previously by our group was further developed and modified. Three different protocols were used to dissect the contribution of each of the three mechanisms to stroke work improvement. Results Resynchronization of ventricular contraction did not lead to significant stroke work improvement. Efficient preloading of the ventricles by a properly timed atrial contraction was the predominant mechanism underlying stroke work improvement. Stroke work improvement peaked at an intermediate AV delay, as it allowed ventricular filling by atrial contraction to occur at a low diastolic LV pressure but also provided adequate time for ventricular filling before ventricular contraction. Diminution of mitral regurgitation by CRT led to stroke work worsening instead of improvement. Conclusion Efficient preloading of the ventricles by a properly timed atrial contraction is responsible for significant stroke work improvement in the acute CRT response. PMID:23928177

  3. Assessment of the right ventricular function in patients with chronic obstructive pulmonary disease and cor pulmonale using cardiac 64-slice spiral CT comparing with 1.7 T MRI

    International Nuclear Information System (INIS)

    Gao Yan; Li Kuncheng; Du Xiangying; Liang Lei; Cao Lizhen; Li Yan; Zhao Shen; Guo Ying

    2009-01-01

    Objective: To assess the right ventricular function in patients with moderate to severe chronic obstructive pulmonary disease (COPD) and eor pulmonale using cardiac 64 MSCT comparing with MRI. Methods: Forty-six patients with COPD determined by pulmonary function test (PFT) were prospectively studied. According to the Global Initiative for COPD classification, the COPD patients were divided into three groups depending on the severity of the disease: mild COPD (16 cases), moderate COPD (16 cases) and severe COPD (14 cases). Twenty age-matched subjects were included as the controls. The RV function was assessed by 64-MSCT and 1.5 T cardiac MRI in all four groups. Pearson correlation analysis was used to evaluate the relationship between the right ventricular ejection fraction (RVEF), myocardial mass (MM) and the PFT results in COPD patients. AP value of less than 0.05 was considered statistically significant. End-diastolic volume (EDV), end-systolic volume (ESV), RVEF and MM on MSCT were compared with that on MRI using Pearson correlation analysis. Bland-Airman plot was used to evaluate the correlation between MSCT and MRI. Results: The RVEF was (51.6 ± 5.6)% in mild COPD, (49.8 ± 6.0)% in moderate COPD, (39.4 ± 7.2)% in severe COPD, and (53 ± 5.9)% in controls, respectively. The MM was (44.5 ± 5.4) g in mild COPD, (49.6 ± 5.0) g in moderate COPD, (57.1 ± 3.4) g in severe COPD, and (40.8 ± 3.9) g in controls, respectively. The EDV was (139.9 ± 25.0), (130.2 ± 21.2), (107.6 ± 18.4) and (149.2 ± 27.9) ml, the SV was (72.1 ± 16.1), (64.3 ± 11.0), (42.5 ± 16.5) and (77.0 ± 11.7) ml in four groups, respectively. The values of RVEF and RVEDV were significantly lower in severe COPD than that in mild COPD, moderate COPD and controls (F RVEF =143, F RVEDV =38.07, P RVEF = 1.03, F EDV =3.22, F EFV =0.44, F SV =2.77, P>0.05). The MM of the RV was significantly different between controls and the other three groups (F=66.34, P<0.01). All parameters of the RV

  4. Diagnostic value of Doppler echocardiography for identifying hemodynamic significant pulmonary valve regurgitation in tetralogy of Fallot: comparison with cardiac MRI.

    Science.gov (United States)

    Beurskens, Niek E G; Gorter, Thomas M; Pieper, Petronella G; Hoendermis, Elke S; Bartelds, Beatrijs; Ebels, Tjark; Berger, Rolf M F; Willems, Tineke P; van Melle, Joost P

    2017-11-01

    Quantification of pulmonary regurgitation (PR) is essential in the management of patients with repaired tetralogy of Fallot (TOF). We sought to evaluate the accuracy of first-line Doppler echocardiography in comparison with cardiac magnetic resonance imaging (MRI) to identify hemodynamic significant PR. Paired cardiac MRI and echocardiographic studies (n = 97) in patients with repaired TOF were retrospectively analyzed. Pressure half time (PHT) and pulmonary regurgitation index (PRi) were measured using continuous wave Doppler. The ratio of the color flow Doppler regurgitation jet width to pulmonary valve (PV) annulus (jet/annulus ratio) and diastolic to systolic time velocity integral (DSTVI; pulsed wave Doppler) were assessed. Accuracy of echocardiographic measurements was tested to identify significant PR as determined by phase-contrast MRI (PR fraction [PRF] ≥ 20%). Mean PRF was 29.4 ± 15.7%. PHT < 100 ms had a sensitivity of 93%, specificity 75%, positive predictive value (PPV) 92% and negative predictive value (NPV) 78% for identifying significant PR (C-statistic 0.82). PRi < 0.77 had sensitivity and specificity of 66% and 54%, respectively (C-statistic 0.63). Jet/annulus ratio ≥1/3 had sensitivity 96%, specificity 75%, PPV 92% and NPV 82% (C-statistic 0.87). DSTVI had sensitivity 84%, specificity 33%, PPV 84% and NPV 40%, (C-statistic 0.56). Combined jet/annulus ratio ≥1/3 and PHT < 100 ms was highly accurate in identifying PRF ≥ 20%, with sensitivity 97% and specificity 100%. PHT and jet/annulus ratio on Doppler echocardiography, especially when combined, are highly accurate in identifying significant PR and therefore seem useful in the follow-up of patients with repaired TOF.

  5. Cardiac and pericardial tumors: A potential application of positron emission tomography-magnetic resonance imaging.

    Science.gov (United States)

    Fathala, Ahmed; Abouzied, Mohei; AlSugair, Abdul-Aziz

    2017-07-26

    Cardiac and pericardial masses may be neoplastic, benign and malignant, non-neoplastic such as thrombus or simple pericardial cysts, or normal variants cardiac structure can also be a diagnostic challenge. Currently, there are several imaging modalities for diagnosis of cardiac masses; each technique has its inherent advantages and disadvantages. Echocardiography, is typically the initial test utilizes in such cases, Echocardiography is considered the test of choice for evaluation and detection of cardiac mass, it is widely available, portable, with no ionizing radiation and provides comprehensive evaluation of cardiac function and valves, however, echocardiography is not very helpful in many cases such as evaluation of extracardiac extension of mass, poor tissue characterization, and it is non diagnostic in some cases. Cross sectional imaging with cardiac computed tomography provides a three dimensional data set with excellent spatial resolution but utilizes ionizing radiation, intravenous iodinated contrast and relatively limited functional evaluation of the heart. Cardiac magnetic resonance imaging (CMR) has excellent contrast resolution that allows superior soft tissue characterization. CMR offers comprehensive evaluation of morphology, function, tissue characterization. The great benefits of CMR make CMR a highly useful tool in the assessment of cardiac masses. (Fluorine 18) fluorodeoxygluocse (FDG) positron emission tomography (PET) has become a corner stone in several oncological application such as tumor staging, restaging, treatment efficiency, FDG is a very useful imaging modality in evaluation of cardiac masses. A recent advance in the imaging technology has been the development of integrated PET-MRI system that utilizes the advantages of PET and MRI in a single examination. FDG PET-MRI provides complementary information on evaluation of cardiac masses. The purpose of this review is to provide several clinical scenarios on the incremental value of PET

  6. Clinical study on the adriamycin induced cardiomyopathy using the cardiac magnetic resonance imaging. Total dose and cardiac dysfunction

    International Nuclear Information System (INIS)

    Yamaguchi, Kyoko; Teraoka, Kunihiko; Hirano, Masaharu

    2001-01-01

    We studied cardiac functional disorders caused by Adoriamycin using gadolinium (Gd) contrast cine MRI. Forty-eight patients were given ACT (31 men and 17 women; mean age, 52±15 years). First, the relationship between dose and the left ventricular volume, cardiac function, left ventricular cardiac mass and localized wall motion were examined in all patients. Patients given a total dose of 300 mg/m 2 or higher were assigned to the high dose group and those given doses under 300 mg/m 2 to the low dose group. The same parameters were studied in both groups and compared. A 1.5-Tesla superconductive MRI was used for all studies. Cine images of the long and short axes at the papillary muscle level were obtained by ECG R-wave synchronized Gd contrast cine MRI. Left ventricular volume and cardiac function were analyzed using the long-axis cine images and the wall thickness in diastole and systole was measured at each site using the short-axis cine images. The percentage of wall thickness was calculated at each site. The mean ACT dose was 273.3±218.2 mg/m 2 . In all patients the total dose directly correlated with ESVI and inversely correlated with the ejection fraction (EF). In the high dose group, the total dose and EF were inversely correlated, but no significant differences were observed in the low dose group. In the high dose group, the ESVI was significantly greater and the SVI and EF were more significantly reduced than in the low dose group. In the high dose group, the thickness of the anterior, lateral and posterior walls, excluding the septum, was significantly lower than in the low dose group. However, changes in wall thickness were not significantly different between the groups. Gd contrast cine MRI was useful in examining cardiac functional disorders caused by anthracyclines. The total dose of anthracycline correlated directly with the ESVI, and inversely with the EF. A total dose of 300 mg/m 2 appeared to be the borderline dose beyond which there were

  7. Clinical study on the adriamycin induced cardiomyopathy using the cardiac magnetic resonance imaging. Total dose and cardiac dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Kyoko; Teraoka, Kunihiko; Hirano, Masaharu [Tokyo Medical Coll. (Japan)

    2001-05-01

    We studied cardiac functional disorders caused by Adoriamycin using gadolinium (Gd) contrast cine MRI. Forty-eight patients were given ACT (31 men and 17 women; mean age, 52{+-}15 years). First, the relationship between dose and the left ventricular volume, cardiac function, left ventricular cardiac mass and localized wall motion were examined in all patients. Patients given a total dose of 300 mg/m{sup 2} or higher were assigned to the high dose group and those given doses under 300 mg/m{sup 2} to the low dose group. The same parameters were studied in both groups and compared. A 1.5-Tesla superconductive MRI was used for all studies. Cine images of the long and short axes at the papillary muscle level were obtained by ECG R-wave synchronized Gd contrast cine MRI. Left ventricular volume and cardiac function were analyzed using the long-axis cine images and the wall thickness in diastole and systole was measured at each site using the short-axis cine images. The percentage of wall thickness was calculated at each site. The mean ACT dose was 273.3{+-}218.2 mg/m{sup 2}. In all patients the total dose directly correlated with ESVI and inversely correlated with the ejection fraction (EF). In the high dose group, the total dose and EF were inversely correlated, but no significant differences were observed in the low dose group. In the high dose group, the ESVI was significantly greater and the SVI and EF were more significantly reduced than in the low dose group. In the high dose group, the thickness of the anterior, lateral and posterior walls, excluding the septum, was significantly lower than in the low dose group. However, changes in wall thickness were not significantly different between the groups. Gd contrast cine MRI was useful in examining cardiac functional disorders caused by anthracyclines. The total dose of anthracycline correlated directly with the ESVI, and inversely with the EF. A total dose of 300 mg/m{sup 2} appeared to be the borderline dose beyond

  8. MRI of cardiovascular malformations

    Energy Technology Data Exchange (ETDEWEB)

    Kastler, Bruno [Centre Hospitalier Univ. Jean Minjoz, Besancon (France); Universite de Franche-Comte, Besancon (FR). Lab. I4S (Health, Innovation, Intervention, Imaging, Engineering); Centre Hospitalier Sherbrooke Univ., PQ (Canada). Dept. of Radiology

    2011-07-01

    MRI is a non-invasive and non-ionizing imaging modality that is perfectly suited for the diagnosis and follow-up of both pediatric and adult congenital heart disease. It provides a large field of view and has the unique ability to depict complex cardiac and vascular anatomy and to measure cardiac function and flow within one examination. MRI is the ideal complement to echocardiography whenever the information provided by the latter is limited. This book has been conceived as a self-teaching manual that will assist qualified radiologists, cardiologists, and pediatricians, as well as those in training. It is richly illustrated with numerous images and drawings that cover all usual and most unusual anomalies. The principal author, Professor Bruno Kastler, is head of radiology at Besancon University Hospital, France and is board certified in both radiology and cardiology. (orig.)

  9. MRI of cardiovascular malformations

    International Nuclear Information System (INIS)

    Kastler, Bruno; Universite de Franche-Comte, Besancon; Centre Hospitalier Sherbrooke Univ., PQ

    2011-01-01

    MRI is a non-invasive and non-ionizing imaging modality that is perfectly suited for the diagnosis and follow-up of both pediatric and adult congenital heart disease. It provides a large field of view and has the unique ability to depict complex cardiac and vascular anatomy and to measure cardiac function and flow within one examination. MRI is the ideal complement to echocardiography whenever the information provided by the latter is limited. This book has been conceived as a self-teaching manual that will assist qualified radiologists, cardiologists, and pediatricians, as well as those in training. It is richly illustrated with numerous images and drawings that cover all usual and most unusual anomalies. The principal author, Professor Bruno Kastler, is head of radiology at Besancon University Hospital, France and is board certified in both radiology and cardiology. (orig.)

  10. Left Ventricular Diastolic Function in Type 2 Diabetes Mellitus and the Association With Coronary Artery Calcium Score: A Cardiac MRI Study

    OpenAIRE

    Graça, B; Donato, P; Ferreira, MJ; Castelo-Branco, M; Caseiro-Alves, F

    2014-01-01

    OBJECTIVE: The purpose of this study was to compare cardiac MRI-derived parameters of left ventricular (LV) diastolic function between uncomplicated type 2 diabetes mellitus (DM2) and normoglycemic control subjects and to evaluate whether these parameters of LV diastolic function are related to coronary atherosclerosis. SUBJECTS AND METHODS: We prospectively studied 41 subjects with DM2 and 21 normoglycemic control subjects (30 women and 32 men; mean age, 57.2 ± 7.1 [SD] years) with ...

  11. Valvular heart disease: what does cardiovascular MRI add?

    International Nuclear Information System (INIS)

    Masci, Pier G.; Dymarkowski, Steven; Bogaert, Jan

    2008-01-01

    Although ischemic heart disease remains the leading cause of cardiac-related morbidity and mortality in the industrialized countries, a growing number of mainly elderly patients will experience a problem of valvular heart disease (VHD), often requiring surgical intervention at some stage. Doppler-echocardiography is the most popular imaging modality used in the evaluation of this disease entity. It encompasses, however, some non-negligible constraints which may hamper the quality and thus the interpretation of the exam. Cardiac catheterization has been considered for a long time the reference technique in this field, however, this technique is invasive and considered far from optimal. Cardiovascular magnetic resonance imaging (MRI) is already considered an established diagnostic method for studying ventricular dimensions, function and mass. With improvement of MRI soft- and hardware, the assessment of cardiac valve function has also turned out to be fast, accurate and reproducible. This review focuses on the usefulness of MRI in the diagnosis and management of VHD, pointing out its added value in comparison with more conventional diagnostic means. (orig.)

  12. Valvular heart disease: what does cardiovascular MRI add?

    Energy Technology Data Exchange (ETDEWEB)

    Masci, Pier G.; Dymarkowski, Steven; Bogaert, Jan [Gasthuisberg University Hospital, Department of Radiology, Leuven (Belgium)

    2008-02-15

    Although ischemic heart disease remains the leading cause of cardiac-related morbidity and mortality in the industrialized countries, a growing number of mainly elderly patients will experience a problem of valvular heart disease (VHD), often requiring surgical intervention at some stage. Doppler-echocardiography is the most popular imaging modality used in the evaluation of this disease entity. It encompasses, however, some non-negligible constraints which may hamper the quality and thus the interpretation of the exam. Cardiac catheterization has been considered for a long time the reference technique in this field, however, this technique is invasive and considered far from optimal. Cardiovascular magnetic resonance imaging (MRI) is already considered an established diagnostic method for studying ventricular dimensions, function and mass. With improvement of MRI soft- and hardware, the assessment of cardiac valve function has also turned out to be fast, accurate and reproducible. This review focuses on the usefulness of MRI in the diagnosis and management of VHD, pointing out its added value in comparison with more conventional diagnostic means. (orig.)

  13. Calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated 15O-water PET/CT: 5D-PET

    Directory of Open Access Journals (Sweden)

    Jonny Nordström

    2017-11-01

    Full Text Available Abstract Background Quantitative measurement of myocardial blood flow (MBF is of increasing interest in the clinical assessment of patients with suspected coronary artery disease (CAD. 15O-water positron emission tomography (PET is considered the gold standard for non-invasive MBF measurements. However, calculation of left ventricular (LV volumes and ejection fraction (EF is not possible from standard 15O-water uptake images. The purpose of the present work was to investigate the possibility of calculating LV volumes and LVEF from cardiac-gated parametric blood volume (V B 15O-water images and from first pass (FP images. Sixteen patients with mitral or aortic regurgitation underwent an eight-gate dynamic cardiac-gated 15O-water PET/CT scan and cardiac MRI. V B and FP images were generated for each gate. Calculations of end-systolic volume (ESV, end-diastolic volume (EDV, stroke volume (SV and LVEF were performed with automatic segmentation of V B and FP images, using commercially available software. LV volumes and LVEF were calculated with surface-, count-, and volume-based methods, and the results were compared with gold standard MRI. Results Using V B images, high correlations between PET and MRI ESV (r = 0.89, p  0.86, p < 0.001. Conclusion Calculation of LV volumes and LVEF from dynamic 15O-water PET is feasible and shows good correlation with MRI. However, the analysis method is laborious, and future work is needed for more automation to make the method more easily applicable in a clinical setting.

  14. Incremental value of PET and MRI in the evaluation of cardiovascular abnormalities.

    Science.gov (United States)

    Chalian, Hamid; O'Donnell, James K; Bolen, Michael; Rajiah, Prabhakar

    2016-08-01

    The cardiovascular system is affected by a wide range of pathological processes, including neoplastic, inflammatory, ischemic, and congenital aetiology. Magnetic resonance imaging (MRI) and positron emission tomography (PET) are state-of-the-art imaging modalities used in the evaluation of these cardiovascular disorders. MRI has good spatial and temporal resolutions, tissue characterization and multi-planar imaging/reconstruction capabilities, which makes it useful in the evaluation of cardiac morphology, ventricular and valvar function, disease characterization, and evaluation of myocardial viability. FDG-PET provides valuable information on the metabolic activity of the cardiovascular diseases, including ischemia, inflammation, and neoplasm. MRI and FDG-PET can provide complementary information on the evaluation of several cardiovascular disorders. For example, in cardiac masses, FDG-PET provides the metabolic information for indeterminate cardiac masses. MRI can be used for localizing and characterizing abnormal hypermetabolic foci identified incidentally on PET scan and also for local staging. A recent advance in imaging technology has been the development of integrated PET/MRI systems that utilize the advantages of PET and MRI in a single examination. The goal of this manuscript is to provide a comprehensive review on the incremental value of PET and MRI in the evaluation of cardiovascular diseases. • MRI has good spatial and temporal resolutions, tissue characterization, and multi-planar reconstruction • FDG-PET provides valuable information on the metabolic activity of cardiovascular disorders • PET and MRI provide complementary information on the evaluation of cardiovascular disorders.

  15. Gadolinium-DTPA enhanced MRI in myocardial infarction

    International Nuclear Information System (INIS)

    Dijkman, P.R.M. van.

    1991-01-01

    This thesis focuses on one aspect of cardiac magnetic resonance imaging (MRI) for noninvasive screening of ischemic heart disease: the identification and quantification of acutely infarcted myocardium using gadolineum-diethylene triamine pentaacetic acid (Gd-DTPA) enhanced T1-weighted MRI in a clinical and experimental setting. (author). 296 refs.; 34 figs.; 4 tabs

  16. Automatic assessment of cardiac perfusion MRI

    DEFF Research Database (Denmark)

    Ólafsdóttir, Hildur; Stegmann, Mikkel Bille; Larsson, Henrik B.W.

    2004-01-01

    In this paper, a method based on Active Appearance Models (AAM) is applied for automatic registration of myocardial perfusion MRI. A semi-quantitative perfusion assessment of the registered image sequences is presented. This includes the formation of perfusion maps for three parameters; maximum up...

  17. ASCI 2010 contrast media guideline for cardiac imaging: a report of the Asian Society of Cardiovascular Imaging cardiac computed tomography and cardiac magnetic resonance imaging guideline working group

    Science.gov (United States)

    Kitagawa, Kakuya; Tsai, I-Chen; Chan, Carmen; Yu, Wei; Yong, Hwan Seok; Choi, Byoung Wook

    2010-01-01

    The use of contrast media for cardiac imaging becomes increasing as the widespread of cardiac CT and cardiac MR. A radiologist needs to carefully consider the indication and the injection protocol of contrast media to be used as well as the possibility of adverse effect. There are several guidelines for contrast media in western countries. However, these are focusing the adverse effect of contrast media. The Asian Society of Cardiovascular Imaging, the only society dedicated to cardiovascular imaging in Asia, formed a Working Group and created a guideline, which summarizes the integrated knowledge of contrast media for cardiac imaging. In cardiac imaging, coronary artery evaluation is feasible by non-contrast MR angiography, which can be an alternative examination in high risk patients for the use of iodine contrast media. Furthermore, the body habitus of Asian patients is usually smaller than that of their western counterparts. This necessitates modifications in the injection protocol and in the formula for calculation of estimated glomerular filtration rate. This guideline provided fundamental information for the use of contrast media for Asian patients in cardiac imaging. PMID:20931289

  18. Diagnosis of Acute Global Myocarditis Using Cardiac MRI with Quantitative T1 and T2 Mapping: Case Report and Literature Review

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chul Hwan [Department of Radiology and Research Institute of Radiological Science, Yonsei University Health System, Seoul 135-720 (Korea, Republic of); Choi, Eui-Young [Division of Cardiology, Department of Internal Medicine, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul 135-720 (Korea, Republic of); Greiser, Andreas [Healthcare Sector, Siemens AG, Erlangen D-91052 (Germany); Paek, Mun Young [Siemens Ltd., Seoul 120-837 (Korea, Republic of); Hwang, Sung Ho; Kim, Tae Hoon [Department of Radiology and Research Institute of Radiological Science, Yonsei University Health System, Seoul 135-720 (Korea, Republic of)

    2013-07-01

    The diagnosis of myocarditis can be challenging given that symptoms, clinical exam findings, electrocardiogram results, biomarkers, and echocardiogram results are often non-specific. Endocardial biopsy is an established method for diagnosing myocarditis, but carries the risk of complications and false negative results. Cardiac magnetic resonance imaging (MRI) has become the primary non-invasive imaging tool in patients with suspected myocarditis. Myocarditis can be diagnosed by using three tissue markers including edema, hyperemia/capillary leak, and necrosis/fibrosis. The interpretation of cardiac MR findings can be confusing, especially when the myocardium is diffusely involved. Using T1 and T2 maps, the diagnosis of myocarditis can be made even in cases of global myocarditis with the help of quantitative analysis. We herein describe a case of acute global myocarditis which was diagnosed by using quantitative T1 and T2 mapping.

  19. Tuple image multi-scale optical flow for detailed cardiac motion extraction: Application to left ventricle rotation analysis

    NARCIS (Netherlands)

    Assen, van H.C.; Florack, L.M.J.; Westenberg, J.J.M.; Haar Romenij, ter B.M.; Hamarneh, G.; Abugharbieh, R.

    2008-01-01

    We present a new method for detailed tracking of cardiac motion based on MR-tagging imaging, multi-scale optical flow, and HARP-like image filtering.In earlier work, we showed that the results obtained with our method correlate very well with Phase Contrast MRI. In this paper we combine the

  20. Minimally Invasive Cardiac Surgery: Transapical Aortic Valve Replacement

    Directory of Open Access Journals (Sweden)

    Ming Li

    2012-01-01

    Full Text Available Minimally invasive cardiac surgery is less traumatic and therefore leads to quicker recovery. With the assistance of engineering technologies on devices, imaging, and robotics, in conjunction with surgical technique, minimally invasive cardiac surgery will improve clinical outcomes and expand the cohort of patients that can be treated. We used transapical aortic valve implantation as an example to demonstrate that minimally invasive cardiac surgery can be implemented with the integration of surgical techniques and engineering technologies. Feasibility studies and long-term evaluation results prove that transapical aortic valve implantation under MRI guidance is feasible and practical. We are investigating an MRI compatible robotic surgical system to further assist the surgeon to precisely deliver aortic valve prostheses via a transapical approach. Ex vivo experimentation results indicate that a robotic system can also be employed in in vivo models.

  1. Rationale and design of the Multidisciplinary Approach to Novel Therapies in Cardiology Oncology Research Trial (MANTICORE 101 - Breast): a randomized, placebo-controlled trial to determine if conventional heart failure pharmacotherapy can prevent trastuzumab-mediated left ventricular remodeling among patients with HER2+ early breast cancer using cardiac MRI

    International Nuclear Information System (INIS)

    Pituskin, Edith; Paterson, Ian; Haykowsky, Mark; Mackey, John R; Thompson, Richard B; Ezekowitz, Justin; Koshman, Sheri; Oudit, Gavin; Chow, Kelvin; Pagano, Joseph J

    2011-01-01

    MANTICORE 101 - Breast (Multidisciplinary Approach to Novel Therapies in Cardiology Oncology Research) is a randomized trial to determine if conventional heart failure pharmacotherapy (angiotensin converting enzyme inhibitor or beta-blocker) can prevent trastuzumab-mediated left ventricular remodeling, measured with cardiac MRI, among patients with HER2+ early breast cancer. One hundred and fifty-nine patients with histologically confirmed HER2+ breast cancer will be enrolled in a parallel 3-arm, randomized, placebo controlled, double-blind design. After baseline assessments, participants will be randomized in a 1:1:1 ratio to an angiotensin-converting enzyme inhibitor (perindopril), beta-blocker (bisoprolol), or placebo. Participants will receive drug or placebo for 1 year beginning 7 days before trastuzumab therapy. Dosages for all groups will be systematically up-titrated, as tolerated, at 1 week intervals for a total of 3 weeks. The primary objective of this randomized clinical trial is to determine if conventional heart failure pharmacotherapy can prevent trastuzumab-mediated left ventricular remodeling among patients with HER2+ early breast cancer, as measured by 12 month change in left ventricular end-diastolic volume using cardiac MRI. Secondary objectives include 1) determine the evolution of left ventricular remodeling on cardiac MRI in patients with HER2+ early breast cancer, 2) understand the mechanism of trastuzumab mediated cardiac toxicity by assessing for the presence of myocardial injury and apoptosis on serum biomarkers and cardiac MRI, and 3) correlate cardiac biomarkers of myocyte injury and extra-cellular matrix remodeling with left ventricular remodeling on cardiac MRI in patients with HER2+ early breast cancer. Cardiac toxicity as a result of cancer therapies is now recognized as a significant health problem of increasing prevalence. To our knowledge, MANTICORE will be the first randomized trial testing proven heart failure pharmacotherapy in

  2. MRI in patients with pacemakers? First global consensus recommendations from radiologists and cardiologists

    International Nuclear Information System (INIS)

    Heindel, Walter; Kugel, Harald

    2017-01-01

    Under the title ''MR Imaging in Patients with Cardiac Pacemakers and Implantable Cardioverter Defibrillators'', this issue of Roefo - simultaneously with the journal of the German Cardiac Society ''Der Kardiologe'' - presents a consensus paper of the German Roentgen Society and the German Cardiac Society [1] [2] that was jointly written by the authors in radiology and cardiology but does not exclusively address cardiac MRI. This publication relates to MR imaging of all regions of the body. In Germany and internationally the number of MRI examinations is increasing: 1,008,944 examinations were performed on patients receiving inpatient treatment in 2005 while 1,767,005 examinations were performed in 2013 (DRG hospitals). This development can be attributed to our aging population as well as to new indications for MRI including: Analyses of tissue composition and function, for example in the liver [3] [4] and the heart [5] [6]; multiparametric analyses of MR perfusion, e.g. in treated brain tumors [7]; new organs such as the lung [8]; dedicated examinations for intervention planning and operation monitoring [9] [10] [11]; as well as MRI-guided interventions [12] [13] [14] [15] [16]. Implants must always be considered in all of these MRI examinations even if the reason for the examination request is not related to an implant. The involvement of cardiology in this case is not based on the medical issue but rather on the type of implant. Expertise in cardiology is required when dealing with cardiac pacemakers (PM) and implantable cardioverter defibrillators (ICD).

  3. From the Weinberg Angle to Cardiac MRI a career change

    CERN Document Server

    ten Have, I.

    1997-01-01

    In summer 1994 I left particle physics to pursue a career in industry. Now three years later I am working for Philips Medical Systems in the Netherlands. I am responsible, both technically and commercially, for adapting the exist-ingMagnetic Resonance Imaging (MRI) technique for cardiology applications. In this seminar I will talk about the interesting challenges my current position holds for me. I will present the substantial added value of my working experience at CERN: the physics research, working at technological frontiers, the international collaboration, expatriate life. Finally I will also describe what I have done to actively support this career change. Speaker: 1985-1989 Ð University of Nijmegen and CERN - Ph.D. on B0-B0bar mixing, Eurojet, top quark cross-sections, test of the O(as3) QCD matrix element, calculations for future hadron colliders, UA1. 1989-1994 Ð University of Glasgow and CERN - ALEPH - Jet charge studies, measurement of the Weinberg Angle. 1994-1996 Ð Master of Business Administr...

  4. Subjective perception of safety in healthy individuals working with 7 T MRI scanners: a retrospective multicenter survey.

    Science.gov (United States)

    Fatahi, Mahsa; Demenescu, Liliana Ramona; Speck, Oliver

    2016-06-01

    To retrospectively assess perception of safety of healthy individuals working with human 7 Tesla (T) magnetic resonance imaging (MRI) scanners. A total of 66 healthy individuals with a mean age of 31 ± 7 years participated in this retrospective multicentre survey study. Nonparametric correlation analysis was conducted to evaluate the relation between self-reported perception of safety and prevalence of sensory effects while working with 7 T MRI scanners for an average 47 months. The results indicated that 98.5 % of the study participants had a neutral or positive feeling about safety aspects at 7 T MRI scanners. 45.5 % reported that they feel very safe and none of the participants stated that they feel moderately or very unsafe while working with 7 T MRI scanners. Perception of safety was not affected by the number of hours per week spent in the vicinity of the 7 T MRI scanner or the duration of experience with 7 T MRI. More than 50 % of individuals experienced vertigo and metallic taste while working with 7 T MRI scanners. However, participants' perceptions of safety were not affected by the prevalence of MR-related symptoms. The overall data indicated an average perception of a moderately safe work environment. To our knowledge, this study delineates the first attempt to assess the subjective safety perception among 7 T MRI workers and suggests further investigations are indicated.

  5. Understanding the physiology of complex congenital heart disease using cardiac magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kappanayil, Mahesh; Kannan, Rajesh; Kumar, Raman Krishna

    2011-01-01

    Complex congenital heart diseases are often associated with complex alterations in hemodynamics. Understanding these key hemodynamic changes is critical to making management decisions including surgery and postoperative management. Existing tools for imaging and hemodynamic assessment like echocardiography, computed tomography and cardiac catheterization have inherent limitations. Cardiac magnetic resonance imaging (MRI) is emerging as a powerful bouquet of tools that allow not only excellent imaging, but also a unique insight into hemodynamics. This article introduces the reader to cardiac MRI and its utility through the clinical example of a child with a complex congenital cyanotic heart disease

  6. In vitro assessment of cardiac performance after irradiation using an isolated working rat heart preparation

    International Nuclear Information System (INIS)

    Wondergem, J.; Laarse, A. van der; Ravels, F.J.M. van; Wermeskerken, A.-M. van; Verhoeve, H.R.; Graaf, B.W. de; Leer, J.W.H.

    1991-01-01

    The effect of irradiation on cardiac function was assessed using an isolated working rat heart preparation. The animals were given single doses of X-rays in the range 15-30 Gy to their hearts. Cardiac output (CO = aortic flow + coronary flow), heart weight and body weight were followed for a period of 10 months after treatment. Irradiation led to a decrease in cardiac function. This reduction was dose-dependent and progressive with time after treatment. The shape of the Frank-Starling curves constructed for irradiated hearts suggests a loss of contractile function of the myocardium. Coronary flow rates measured in 'working' hearts and in 'Langendorff' hearts were not significantly changed by the irradiation treatment. The isolated working rat heart preparation proved to be a simple and suitable animal model for the investigation of irradiation-induced cardiotoxicity. (author)

  7. A Two-dimensional Sixteen Channel Transmit/Receive Coil Array for Cardiac MRI at 7.0 Tesla: Design, Evaluation and Application

    Science.gov (United States)

    Thalhammer, Christof; Renz, Wolfgang; Winter, Lukas; Hezel, Fabian; Rieger, Jan; Pfeiffer, Harald; Graessl, Andreas; Seifert, Frank; Hoffmann, Werner; von Knobelsdorff-Brenkenhoff, Florian; Tkachenko, Valeriy; Schulz-Menger, Jeanette; Kellman, Peter; Niendorf, Thoralf

    2012-01-01

    Purpose To design, evaluate and apply a two-dimensional 16 channel transmit/receive coil array tailored for cardiac MRI at 7.0 Tesla. Material and Methods The cardiac coil array consists of 2 sections each using 8 elements arranged in a 2 × 4 array. RF safety was validated by SAR simulations. Cardiac imaging was performed using 2D CINE FLASH imaging, T2* mapping and fat-water separation imaging. The characteristics of the coil array were analyzed including parallel imaging performance, left ventricular chamber quantification and overall image quality. Results RF characteristics were found to be appropriate for all subjects included in the study. The SAR values derived from the simulations fall well in the limits of legal guidelines. The baseline SNR advantage at 7.0 T was put to use to acquire 2D CINE images of the heart with a very high spatial resolution of (1 × 1 × 4) mm3. The proposed coil array supports 1D acceleration factors of up to R=4 without impairing image quality significantly. Conclusions The 16 channel TX/RX coil has the capability to acquire high contrast and high spatial resolution images of the heart at 7.0 Tesla. PMID:22706727

  8. Does caffeine modulate verbal working memory processes? An fMRI study.

    Science.gov (United States)

    Koppelstaetter, F; Poeppel, T D; Siedentopf, C M; Ischebeck, A; Verius, M; Haala, I; Mottaghy, F M; Rhomberg, P; Golaszewski, S; Gotwald, T; Lorenz, I H; Kolbitsch, C; Felber, S; Krause, B J

    2008-01-01

    To assess the effect of caffeine on the functional MRI signal during a 2-back verbal working memory task, we examined blood oxygenation level-dependent regional brain activity in 15 healthy right-handed males. The subjects, all moderate caffeine consumers, underwent two scanning sessions on a 1.5-T MR-Scanner separated by a 24- to 48-h interval. Each participant received either placebo or 100 mg caffeine 20 min prior to the performance of the working memory task in blinded crossover fashion. The study was implemented as a blocked-design. Analysis was performed using SPM2. In both conditions, the characteristic working memory network of frontoparietal cortical activation including the precuneus and the anterior cingulate could be shown. In comparison to placebo, caffeine caused an increased response in the bilateral medial frontopolar cortex (BA 10), extending to the right anterior cingulate cortex (BA 32). These results suggest that caffeine modulates neuronal activity as evidenced by fMRI signal changes in a network of brain areas associated with executive and attentional functions during working memory processes.

  9. Implementing a working together model for Aboriginal patients with acute coronary syndrome: an Aboriginal Hospital Liaison Officer and a specialist cardiac nurse working together to improve hospital care.

    Science.gov (United States)

    Daws, Karen; Punch, Amanda; Winters, Michelle; Posenelli, Sonia; Willis, John; MacIsaac, Andrew; Rahman, Muhammad Aziz; Worrall-Carter, Linda

    2014-11-01

    Acute coronary syndrome (ACS) contributes to the disparity in life expectancy between Aboriginal and non-Aboriginal Australians. Improving hospital care for Aboriginal patients has been identified as a means of addressing this disparity. This project developed and implemented a working together model of care, comprising an Aboriginal Hospital Liaison Officer and a specialist cardiac nurse, providing care coordination specifically directed at improving attendance at cardiac rehabilitation services for Aboriginal Australians in a large metropolitan hospital in Melbourne. A quality improvement framework using a retrospective case notes audit evaluated Aboriginal patients' admissions to hospital and identified low attendance rates at cardiac rehabilitation services. A working together model of care coordination by an Aboriginal Hospital Liaison Officer and a specialist cardiac nurse was implemented to improve cardiac rehabilitation attendance in Aboriginal patients admitted with ACS to the cardiac wards of the hospital. A retrospective medical records audit showed that there were 68 Aboriginal patients admitted to the cardiac wards with ACS from 1 July 2008 to 30 June 2011. A referral to cardiac rehabilitation was recorded for 42% of these. During the implementation of the model of care, 13 of 15 patients (86%) received a referral to cardiac rehabilitation and eight of the 13 (62%) attended. Implementation of the working together model demonstrated improved referral to and attendance at cardiac rehabilitation services, thereby, has potential to prevent complications and mortality. WHAT IS KNOWN ABOUT THE TOPIC?: Aboriginal Australians experience disparities in access to recommended care for acute coronary syndrome. This may contribute to the life expectancy gap between Aboriginal and non-Aboriginal Australians. WHAT DOES THIS PAPER ADD?: This paper describes a model of care involving an Aboriginal Hospital Liaisons Officer and a specialist cardiac nurse working

  10. Simultaneous pressure-volume measurements using optical sensors and MRI for left ventricle function assessment during animal experiment.

    Science.gov (United States)

    Abi-Abdallah Rodriguez, Dima; Durand, Emmanuel; de Rochefort, Ludovic; Boudjemline, Younes; Mousseaux, Elie

    2015-01-01

    Simultaneous pressure and volume measurements enable the extraction of valuable parameters for left ventricle function assessment. Cardiac MR has proven to be the most accurate method for volume estimation. Nonetheless, measuring pressure simultaneously during MRI acquisitions remains a challenge given the magnetic nature of the widely used pressure transducers. In this study we show the feasibility of simultaneous in vivo pressure-volume acquisitions with MRI using optical pressure sensors. Pressure-volume loops were calculated while inducing three inotropic states in a sheep and functional indices were extracted, using single beat loops, to characterize systolic and diastolic performance. Functional indices evolved as expected in response to positive inotropic stimuli. The end-systolic elastance, representing the contractility index, the diastolic myocardium compliance, and the cardiac work efficiency all increased when inducing inotropic state enhancement. The association of MRI and optical pressure sensors within the left ventricle successfully enabled pressure-volume loop analysis after having respective data simultaneously recorded during the experimentation without the need to move the animal between each inotropic state. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  11. Diffusion-weighted MRI in acute posterior ischemic optic neuropathy

    International Nuclear Information System (INIS)

    Srinivasan, Sivasubramanian; Moorthy, Srikant; Sreekumar, KP; Kulkarni, Chinmay

    2012-01-01

    Blindness following surgery, especially cardiac surgery, has been reported sporadically, the most common cause being ischemic optic neuropathy. The role of MRI in the diagnosis of this condition is not well established. We present a case of postoperative posterior ischemic optic neuropathy that was diagnosed on diffusion-weighted MRI

  12. Denoising human cardiac diffusion tensor magnetic resonance images using sparse representation combined with segmentation

    International Nuclear Information System (INIS)

    Bao, L J; Zhu, Y M; Liu, W Y; Pu, Z B; Magnin, I E; Croisille, P; Robini, M

    2009-01-01

    Cardiac diffusion tensor magnetic resonance imaging (DT-MRI) is noise sensitive, and the noise can induce numerous systematic errors in subsequent parameter calculations. This paper proposes a sparse representation-based method for denoising cardiac DT-MRI images. The method first generates a dictionary of multiple bases according to the features of the observed image. A segmentation algorithm based on nonstationary degree detector is then introduced to make the selection of atoms in the dictionary adapted to the image's features. The denoising is achieved by gradually approximating the underlying image using the atoms selected from the generated dictionary. The results on both simulated image and real cardiac DT-MRI images from ex vivo human hearts show that the proposed denoising method performs better than conventional denoising techniques by preserving image contrast and fine structures.

  13. Detection of pericardial inflammation with late-enhancement cardiac magnetic resonance imaging: initial results

    International Nuclear Information System (INIS)

    Taylor, Andrew M.; Dymarkowski, Steven; Bogaert, Jan; Verbeken, Eric K.

    2006-01-01

    To examine the value of late-enhancement cardiac magnetic resonance imaging (MRI) for detection of pericardial inflammation. Late-enhancement cardiac MRI was performed in 16 patients with clinical suspicion of pericardial disease. Pericardial effusion, pericardial thickening and pericardial enhancement were assessed. MRI findings were compared with those of definitive pericardial histology (n=14) or microbiology (n=2). A control group of 12 patients with no clinical evidence of pericardial disease were also imaged with the same MRI protocol. Sensitivity and specificity for late-enhancement MRI detection of pericardial inflammation was of 100%. There was MRI late enhancement of the pericardial layers in all five patients with histological/microbiological evidence of inflammatory pericarditis. MRI demonstrated no pericardial thickening and no MRI late enhancement with or without a pericardial effusion in any of the five patients with histological evidence of a normal pericardium. MRI detected pericardial thickening in the absence of both pericardial effusion and late enhancement in all six patients with histological evidence of chronic fibrosing pericarditis. The 12 control subjects showed no evidence of pericardial MRI late enhancement. These findings demonstrate that MRI late enhancement can be used to visualize pericardial inflammation in patients with clinical suspicion of pericardial disease. (orig.)

  14. Evaluation of cardiac and hepatic iron overload in thalassemia major patients with T2* magnetic resonance imaging.

    Science.gov (United States)

    Wahidiyat, Pustika Amalia; Liauw, Felix; Sekarsari, Damayanti; Putriasih, Siti Ayu; Berdoukas, Vasili; Pennell, Dudley J

    2017-09-01

    Recent advancements have promoted the use of T2* magnetic resonance imaging (MRI) in the non-invasive detection of iron overload in various organs for thalassemia major patients. This study aims to determine the iron load in the heart and liver of patients with thalassemia major using T2* MRI and to evaluate its correlation with serum ferritin level and iron chelation therapy. This cross-sectional study included 162 subjects diagnosed with thalassemia major, who were classified into acceptable, mild, moderate, or severe cardiac and hepatic iron overload following their T2* MRI results, respectively, and these were correlated to their serum ferritin levels and iron chelation therapy. The study found that 85.2% of the subjects had normal cardiac iron stores. In contrast, 70.4% of the subjects had severe liver iron overload. A significant but weak correlation (r = -0.28) was found between cardiac T2* MRI and serum ferritin, and a slightly more significant correlation (r = 0.37) was found between liver iron concentration (LIC) and serum ferritin. The findings of this study are consistent with several other studies, which show that patients generally manifest with liver iron overload prior to cardiac iron overload. Moreover, iron accumulation demonstrated by T2* MRI results also show a significant correlation to serum ferritin levels. This is the first study of its kind conducted in Indonesia, which supports the fact that T2* MRI is undoubtedly valuable in the early detection of cardiac and hepatic iron overload in thalassemia major patients.

  15. MRI of the Chest

    Medline Plus

    Full Text Available ... types of clips used for brain aneurysms some types of metal coils placed within blood vessels nearly all cardiac defibrillators and pacemakers You ... a preferred imaging test. MR imaging can assess blood flow without ... the opening of certain types of MRI machines. The presence of an implant ...

  16. Delayed Recall and Working Memory MMSE Domains Predict Delirium following Cardiac Surgery.

    Science.gov (United States)

    Price, Catherine C; Garvan, Cynthia; Hizel, Loren P; Lopez, Marcos G; Billings, Frederic T

    2017-01-01

    Reduced preoperative cognition is a risk factor for postoperative delirium. The significance for type of preoperative cognitive deficit, however, has yet to be explored and could provide important insights into mechanisms and prediction of delirium. Our goal was to determine if certain cognitive domains from the general cognitive screener, the Mini-Mental State Exam (MMSE), predict delirium after cardiac surgery. Patients completed a preoperative MMSE prior to undergoing elective cardiac surgery. Following surgery, delirium was assessed throughout ICU stay using the Confusion Assessment Method for ICU delirium and the Richmond Agitation and Sedation Scale. Cardiac surgery patients who developed delirium (n = 137) had lower total MMSE scores than patients who did not develop delirium (n = 457). In particular, orientation to place, working memory, delayed recall, and language domain scores were lower. Of these, only the working memory and delayed recall domains predicted delirium in a regression model adjusting for history of chronic obstructive pulmonary disease, age, sex, and duration of cardiopulmonary bypass. For each word not recalled on the three-word delayed recall assessment, the odds of delirium increased by 50%. For each item missed on the working memory index, the odds of delirium increased by 36%. Of the patients who developed delirium, 47% had a primary impairment in memory, 21% in working memory, and 33% in both domains. The area under the receiver operating characteristics curve using only the working memory and delayed recall domains was 0.75, compared to 0.76 for total MMSE score. Delirium risk is greater for individuals with reduced MMSE scores on the delayed recall and working memory domains. Research should address why patients with memory and executive vulnerabilities are more prone to postoperative delirium than those with other cognitive limitations.

  17. Simultaneous determination of dynamic cardiac metabolism and function using PET/MRI.

    Science.gov (United States)

    Barton, Gregory P; Vildberg, Lauren; Goss, Kara; Aggarwal, Niti; Eldridge, Marlowe; McMillan, Alan B

    2018-05-01

    Cardiac metabolic changes in heart disease precede overt contractile dysfunction. However, metabolism and function are not typically assessed together in clinical practice. The purpose of this study was to develop a cardiac positron emission tomography/magnetic resonance (PET/MR) stress test to assess the dynamic relationship between contractile function and metabolism in a preclinical model. Following an overnight fast, healthy pigs (45-50 kg) were anesthetized and mechanically ventilated. 18 F-fluorodeoxyglucose ( 18 F-FDG) solution was administered intravenously at a constant rate of 0.01 mL/s for 60 minutes. A cardiac PET/MR stress test was performed using normoxic gas (F I O 2  = .209) and hypoxic gas (F I O 2  = .12). Simultaneous cardiac imaging was performed on an integrated 3T PET/MR scanner. Hypoxic stress induced a significant increase in heart rate, cardiac output, left ventricular (LV) ejection fraction (EF), and peak torsion. There was a significant decline in arterial SpO 2 , LV end-diastolic and end-systolic volumes in hypoxia. Increased LV systolic function was coupled with an increase in myocardial FDG uptake (Ki) during hypoxic stress. PET/MR with continuous FDG infusion captures dynamic changes in both cardiac metabolism and contractile function. This technique warrants evaluation in human cardiac disease for assessment of subtle functional and metabolic abnormalities.

  18. Primary cardiac and pericardial tumors, imaging approach

    Energy Technology Data Exchange (ETDEWEB)

    Yu-Qing Liu, M D [Chinese Academy of Medical Sciences, Beijing, BJ (China). Dept. of Radiology, Fu Wai Hospital and Cardiovascular Inst.

    1996-12-31

    The incidence of cardiac tumor and its classification was discussed. Imaging study i.e. conventional radiology, echocardiagoaphy (echo), magnetic resonance imaging (MRI), angiography and computed tomography (CT) used also discussed briefly. (8 refs.).

  19. Primary cardiac and pericardial tumors, imaging approach

    International Nuclear Information System (INIS)

    Yu-Qing Liu, M.D.

    1995-01-01

    The incidence of cardiac tumor and its classification was discussed. Imaging study i.e. conventional radiology, echocardiagoaphy (echo), magnetic resonance imaging (MRI), angiography and computed tomography (CT) used also discussed briefly. (8 refs.)

  20. Coronary endothelial function assessment using self-gated cardiac cine MRI and k-t sparse SENSE.

    Science.gov (United States)

    Yerly, Jérôme; Ginami, Giulia; Nordio, Giovanna; Coristine, Andrew J; Coppo, Simone; Monney, Pierre; Stuber, Matthias

    2016-11-01

    Electrocardiogram (ECG)-gated cine MRI, paired with isometric handgrip exercise, can be used to accurately, reproducibly, and noninvasively measure coronary endothelial function (CEF). Obtaining a reliable ECG signal at higher field strengths, however, can be challenging due to rapid gradient switching and an increased heart rate under stress. To address these limitations, we present a self-gated cardiac cine MRI framework for CEF measurements that operates without ECG signal. Cross-sectional slices of the right coronary artery (RCA) were acquired using a two-dimensional golden angle radial trajectory. This sampling approach, combined with the k-t sparse SENSE algorithm, allows for the reconstruction of both real-time images for self-gating signal calculations and retrospectively reordered self-gated cine images. CEF measurements were quantitatively compared using both the self-gated and the standard ECG-gated approach. Self-gated cine images with high-quality, temporal, and spatial resolution were reconstructed for 18 healthy volunteers. CEF as measured in self-gated images was in good agreement (R 2  = 0.60) with that measured by its standard ECG-gated counterpart. High spatial and temporal resolution cross-sectional cine images of the RCA can be obtained without ECG signal. The coronary vasomotor response to handgrip exercise compares favorably with that obtained with the standard ECG-gated method. Magn Reson Med 76:1443-1454, 2015. © 2015 International Society for Magnetic Resonance in Medicine. © 2015 International Society for Magnetic Resonance in Medicine.

  1. High frame rate retrospectively triggered Cine MRI for assessment of murine diastolic function.

    Science.gov (United States)

    Coolen, Bram F; Abdurrachim, Desiree; Motaal, Abdallah G; Nicolay, Klaas; Prompers, Jeanine J; Strijkers, Gustav J

    2013-03-01

    To assess left ventricular (LV) diastolic function in mice with Cine MRI, a high frame rate (>60 frames per cardiac cycle) is required. For conventional electrocardiography-triggered Cine MRI, the frame rate is inversely proportional to the pulse repetition time (TR). However, TR cannot be lowered at will to increase the frame rate because of gradient hardware, spatial resolution, and signal-to-noise limitations. To overcome these limitations associated with electrocardiography-triggered Cine MRI, in this paper, we introduce a retrospectively triggered Cine MRI protocol capable of producing high-resolution high frame rate Cine MRI of the mouse heart for addressing left ventricular diastolic function. Simulations were performed to investigate the influence of MRI sequence parameters and the k-space filling trajectory in relation to the desired number of frames per cardiac cycle. An optimized protocol was applied in vivo and compared with electrocardiography-triggered Cine for which a high-frame rate could only be achieved by several interleaved acquisitions. Retrospective high frame rate Cine MRI proved superior to the interleaved electrocardiography-triggered protocols. High spatial-resolution Cine movies with frames rates up to 80 frames per cardiac cycle were obtained in 25 min. Analysis of left ventricular filling rate curves allowed accurate determination of early and late filling rates and revealed subtle impairments in left ventricular diastolic function of diabetic mice in comparison with nondiabetic mice. Copyright © 2012 Wiley Periodicals, Inc.

  2. 2D XD-GRASP provides better image quality than conventional 2D cardiac cine MRI for patients who cannot suspend respiration

    Science.gov (United States)

    Piekarski, Eve; Chitiboi, Teodora; Ramb, Rebecca; Latson, Larry A; Bhatla, Puneet; Feng, Li; Axel, Leon

    2017-01-01

    Object Residual respiratory motion degrades image quality in conventional cardiac cine MRI (CCMR). We evaluated whether a free-breathing (FB) radial imaging CCMR sequence with compressed sensing reconstruction (eXtra-Dimension (e.g. cardiac and respiratory phases) Golden-angle RAdial Sparse Parallel, or XD-GRASP) could provide better image quality than a conventional Cartesian breath-held (BH) sequence, in an unselected population of patients undergoing clinical CCMR. Material and Methods 101 patients who underwent BH and FB imaging in a mid-ventricular short-axis plane at a matching location were included. Visual and quantitative image analysis was performed by two blinded experienced readers, using a 5-point qualitative scale to score overall image quality and visual signal-to-noise ratio (SNR) grade, with measures of noise and sharpness. End-diastole (ED) and end-systole (ES) left-ventricular areas were also measured and compared for both BH and FB images. Results Image quality was generally better with the BH cines (overall quality grade BH vs FB: 4 vs 2.9, pXD-GRASP CCMR was visually inferior to conventional BH cardiac cine in general, it provided improved image quality in the subgroup of patients presenting respiratory motion-induced artifacts on breath-held images. PMID:29067539

  3. A Magnetic Resonance Imaging-Conditional External Cardiac Defibrillator for Resuscitation Within the Magnetic Resonance Imaging Scanner Bore.

    Science.gov (United States)

    Schmidt, Ehud J; Watkins, Ronald D; Zviman, Menekhem M; Guttman, Michael A; Wang, Wei; Halperin, Henry A

    2016-10-01

    Subjects undergoing cardiac arrest within a magnetic resonance imaging (MRI) scanner are currently removed from the bore and then from the MRI suite, before the delivery of cardiopulmonary resuscitation and defibrillation, potentially increasing the risk of mortality. This precludes many higher-risk (acute ischemic and acute stroke) patients from undergoing MRI and MRI-guided intervention. An MRI-conditional cardiac defibrillator should enable scanning with defibrillation pads attached and the generator ON, enabling application of defibrillation within the seconds of MRI after a cardiac event. An MRI-conditional external defibrillator may improve patient acceptance for MRI procedures. A commercial external defibrillator was rendered 1.5 Tesla MRI-conditional by the addition of novel radiofrequency filters between the generator and commercial disposable surface pads. The radiofrequency filters reduced emission into the MRI scanner and prevented cable/surface pad heating during imaging, while preserving all the defibrillator monitoring and delivery functions. Human volunteers were imaged using high specific absorption rate sequences to validate MRI image quality and lack of heating. Swine were electrically fibrillated (n=4) and thereafter defibrillated both outside and inside the MRI bore. MRI image quality was reduced by 0.8 or 1.6 dB, with the generator in monitoring mode and operating on battery or AC power, respectively. Commercial surface pads did not create artifacts deeper than 6 mm below the skin surface. Radiofrequency heating was within US Food and Drug Administration guidelines. Defibrillation was completely successful inside and outside the MRI bore. A prototype MRI-conditional defibrillation system successfully defibrillated in the MRI without degrading the image quality or increasing the time needed for defibrillation. It can increase patient acceptance for MRI procedures. © 2016 American Heart Association, Inc.

  4. Short repetition time multiband echo-planar imaging with simultaneous pulse recording allows dynamic imaging of the cardiac pulsation signal.

    Science.gov (United States)

    Tong, Yunjie; Hocke, Lia M; Frederick, Blaise deB

    2014-11-01

    Recently developed simultaneous multislice echo-planar imaging (EPI) sequences permit imaging of the whole brain at short repetition time (TR), allowing the cardiac fluctuations to be fully sampled in blood-oxygen-level dependent functional MRI (BOLD fMRI). A novel low computational analytical method was developed to dynamically map the passage of the pulsation signal through the brain and visualize the whole cerebral vasculature affected by the pulse signal. This algorithm is based on a simple combination of fast BOLD fMRI and the scanner's own built-in pulse oximeter. Multiple, temporally shifted copies of the pulse oximeter data (with 0.08 s shifting step and coverage of a 1-s span) were downsampled and used as cardiac pulsation regressors in a general linear model based analyses (FSL) of the fMRI data. The resulting concatenated z-statistics maps show the voxels that are affected as the cardiac signal travels through the brain. Many voxels were highly correlated with the pulsation regressor or its temporally shifted version. The dynamic and static cardiac pulsation maps obtained from both the task and resting state scans, resembled cerebral vasculature. The results demonstrated: (i) cardiac pulsation significantly affects most voxels in the brain; (ii) combining fast fMRI and this analytical method can reveal additional clinical information to functional studies. Copyright © 2013 Wiley Periodicals, Inc.

  5. Use of Cardiac Computed Tomography for Ventricular Volumetry in Late Postoperative Patients with Tetralogy of Fallot.

    Science.gov (United States)

    Kim, Ho Jin; Mun, Da Na; Goo, Hyun Woo; Yun, Tae-Jin

    2017-04-01

    Cardiac computed tomography (CT) has emerged as an alternative to magnetic resonance imaging (MRI) for ventricular volumetry. However, the clinical use of cardiac CT requires external validation. Both cardiac CT and MRI were performed prior to pulmonary valve implantation (PVI) in 11 patients (median age, 19 years) who had undergone total correction of tetralogy of Fallot during infancy. The simplified contouring method (MRI) and semiautomatic 3-dimensional region-growing method (CT) were used to measure ventricular volumes. All volumetric indices measured by CT and MRI generally correlated well with each other, except for the left ventricular end-systolic volume index (LV-ESVI), which showed the following correlations with the other indices: the right ventricular end-diastolic volume index (RV-EDVI) (r=0.88, p<0.001), the right ventricular end-systolic volume index (RV-ESVI) (r=0.84, p=0.001), the left ventricular end-diastolic volume index (LV-EDVI) (r=0.90, p=0.001), and the LV-ESVI (r=0.55, p=0.079). While the EDVIs measured by CT were significantly larger than those measured by MRI (median RV-EDVI: 197 mL/m 2 vs. 175 mL/m 2 , p=0.008; median LV-EDVI: 94 mL/m 2 vs. 92 mL/m 2 , p=0.026), no significant differences were found for the RV-ESVI or LV-ESVI. The EDVIs measured by cardiac CT were greater than those measured by MRI, whereas the ESVIs measured by CT and MRI were comparable. The volumetric characteristics of these 2 diagnostic modalities should be taken into account when indications for late PVI after tetralogy of Fallot repair are assessed.

  6. Cardiac MRI and Transthoracic Echocardiography of Left Ventricular Myocardial Noncompaction in A Patient with Congestive Heart Failure: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Eui Min; Byun, Joo Nam [Chosun University Hospital College of Medicine, Gwangju (Korea, Republic of); Kim, Dong Hun [Soonchunhyang University Hospital Bucheon College of Medicine, Bucheon (Korea, Republic of)

    2010-11-15

    We report a case of a 38-year-old male presenting with new-onset dyspnea, that was diagnosed as left ventricular noncompaction by transthoracic echocardiographic and cardiac MR. The tests revealed left ventricular systolic dysfunction with prominent trabeculations associated with deep intertrabecular recesses and an enddiastolic noncompacted to compacted ratio of 2.5 in the whole apical wall and mid-ventricular anterolateral and inferolateral walls. Delayed gadolinium contrast-enhanced MRI revealed subepicardial mid-wall hyperenhancement of the midventricular anteroseptal and inferoseptal walls, which suggested myocardial fibrosis. We review the pathophysiology, clinical characteristics, and diagnostic approach of the left ventricular noncompaction associated with congestive heart failure

  7. The diagnosis of anthracycline-induced cardiac damage and heart failure

    Directory of Open Access Journals (Sweden)

    Jarosław Dudka

    2009-05-01

    Full Text Available Routine examinations during chemotherapy containing anthracyclines evaluate heart function before treatment and monitor cardiotoxic effects during and after therapy. A number of methods are useful in cardiac assessment, including electrocardiography, radiology techniques (RTG, CT, MRI, PET-CT, PET-MRI, echocardiography, radioisotope imaging techniques (scyntygraphy, MUGA, PET, and ultra-structure evaluation in biopsy samples. Nevertheless, there is a continuous need for new methods to predict future damage at the initial stages of cardiac changes. In recent years the therapeutic usefulness of biochemical blood parameters in anthracycline-treated patients has been assessed. The levels of cardiac troponines (cTnI, cTnT, natriuretic peptides (ANP, BNP, and endothelin 1 have been included in the studies. Heart-type fatty acid binding protein (H-FABP is another promising factor showing cardiomyocytic impairment. However, the clinical use of biochemical parameters in diagnosing anthracycline-related cardiotoxicity is still a controversial issue.

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... types of clips used for brain aneurysms some types of metal coils placed within blood vessels nearly all cardiac defibrillators and pacemakers You ... called MR angiography (MRA) provides detailed images of blood vessels in the ... the opening of certain types of MRI machines. The presence of an implant ...

  9. N-back Working Memory Task: Meta-analysis of Normative fMRI Studies With Children.

    Science.gov (United States)

    Yaple, Zachary; Arsalidou, Marie

    2018-05-07

    The n-back task is likely the most popular measure of working memory for functional magnetic resonance imaging (fMRI) studies. Despite accumulating neuroimaging studies with the n-back task and children, its neural representation is still unclear. fMRI studies that used the n-back were compiled, and data from children up to 15 years (n = 260) were analyzed using activation likelihood estimation. Results show concordance in frontoparietal regions recognized for their role in working memory as well as regions not typically highlighted as part of the working memory network, such as the insula. Findings are discussed in terms of developmental methodology and potential contribution to developmental theories of cognition. © 2018 Society for Research in Child Development.

  10. Working memory in volunteers and schizophrenics using BOLD fMRI

    International Nuclear Information System (INIS)

    Giesel, F.L.; Hohmann, N.; Seidl, U.; Kress, K.R.; Schoenknecht, P.; Schroeder, J.; Kauczor, H.-U.; Essig, M.

    2005-01-01

    Functional magnetic resonance imaging uses the blood oxygen level-dependent effect (BOLD MRI) for noninvasive display of cerebral correlatives of cognitive function. The importance for the understanding of physiological and pathological processes is demonstrated by investigations of working memory in schizophrenics and healthy controls. Working memory is involved in processing rather than storage of information and therefore is linked to complex processes such as learning and problem solving. In schizophrenic psychosis, these functions are clearly restricted. Training effects in the working memory task follow an inverse U-shape function, suggesting that cerebral activation reaches a peak before economics of the brain find a more efficient method and activation decreases. (orig.) [de

  11. Isotropic 3D cardiac cine MRI allows efficient sparse segmentation strategies based on 3D surface reconstruction.

    Science.gov (United States)

    Odille, Freddy; Bustin, Aurélien; Liu, Shufang; Chen, Bailiang; Vuissoz, Pierre-André; Felblinger, Jacques; Bonnemains, Laurent

    2018-05-01

    Segmentation of cardiac cine MRI data is routinely used for the volumetric analysis of cardiac function. Conventionally, 2D contours are drawn on short-axis (SAX) image stacks with relatively thick slices (typically 8 mm). Here, an acquisition/reconstruction strategy is used for obtaining isotropic 3D cine datasets; reformatted slices are then used to optimize the manual segmentation workflow. Isotropic 3D cine datasets were obtained from multiple 2D cine stacks (acquired during free-breathing in SAX and long-axis (LAX) orientations) using nonrigid motion correction (cine-GRICS method) and super-resolution. Several manual segmentation strategies were then compared, including conventional SAX segmentation, LAX segmentation in three views only, and combinations of SAX and LAX slices. An implicit B-spline surface reconstruction algorithm is proposed to reconstruct the left ventricular cavity surface from the sparse set of 2D contours. All tested sparse segmentation strategies were in good agreement, with Dice scores above 0.9 despite using fewer slices (3-6 sparse slices instead of 8-10 contiguous SAX slices). When compared to independent phase-contrast flow measurements, stroke volumes computed from four or six sparse slices had slightly higher precision than conventional SAX segmentation (error standard deviation of 5.4 mL against 6.1 mL) at the cost of slightly lower accuracy (bias of -1.2 mL against 0.2 mL). Functional parameters also showed a trend to improved precision, including end-diastolic volumes, end-systolic volumes, and ejection fractions). The postprocessing workflow of 3D isotropic cardiac imaging strategies can be optimized using sparse segmentation and 3D surface reconstruction. Magn Reson Med 79:2665-2675, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  12. Dose-Escalation Study for Cardiac Radiosurgery in a Porcine Model

    Energy Technology Data Exchange (ETDEWEB)

    Blanck, Oliver, E-mail: oliver.blanck@uksh.de [Department of Radiation Oncology, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); CyberKnife Center Northern Germany, Guestrow (Germany); Bode, Frank [Medical Department II, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); Gebhard, Maximilian [Institute of Pathology, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); Hunold, Peter [Department of Radiology and Nuclear Medicine, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); Brandt, Sebastian [Department of Anaesthesiology and Intensive Care Medicine, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); Bruder, Ralf [Institute for Robotics and Cognitive Systems, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); Grossherr, Martin [Department of Anaesthesiology and Intensive Care Medicine, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); Vonthein, Reinhard [Institute of Medical Biometry and Statistics, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); Rades, Dirk [Department of Radiation Oncology, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); Dunst, Juergen [Department of Radiation Oncology, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); University Copenhagen (Denmark)

    2014-07-01

    Purpose: To perform a proof-of-principle dose-escalation study to radiosurgically induce scarring in cardiac muscle tissue to block veno-atrial electrical connections at the pulmonary vein antrum, similar to catheter ablation. Methods and Materials: Nine mini-pigs underwent pretreatment magnetic resonance imaging (MRI) evaluation of heart function and electrophysiology assessment by catheter measurements in the right superior pulmonary vein (RSPV). Immediately after examination, radiosurgery with randomized single-fraction doses of 0 and 17.5-35 Gy in 2.5-Gy steps were delivered to the RSPV antrum (target volume 5-8 cm{sup 3}). MRI and electrophysiology were repeated 6 months after therapy, followed by histopathologic examination. Results: Transmural scarring of cardiac muscle tissue was noted with doses ≥32.5 Gy. However, complete circumferential scarring of the RSPV was not achieved. Logistic regressions showed that extent and intensity of fibrosis significantly increased with dose. The 50% effective dose for intense fibrosis was 31.3 Gy (odds ratio 2.47/Gy, P<.01). Heart function was not affected, as verified by MRI and electrocardiogram evaluation. Adjacent critical structures were not damaged, as verified by pathology, demonstrating the short-term safety of small-volume cardiac radiosurgery with doses up to 35 Gy. Conclusions: Radiosurgery with doses >32.5 Gy in the healthy pig heart can induce circumscribed scars at the RSPV antrum noninvasively, mimicking the effect of catheter ablation. In our study we established a significant dose-response relationship for cardiac radiosurgery. The long-term effects and toxicity of such high radiation doses need further investigation in the pursuit of cardiac radiosurgery for noninvasive treatment of atrial fibrillation.

  13. Use of Cardiac Computed Tomography for Ventricular Volumetry in Late Postoperative Patients with Tetralogy of Fallot

    Directory of Open Access Journals (Sweden)

    Ho Jin Kim

    2017-04-01

    Full Text Available Background: Cardiac computed tomography (CT has emerged as an alternative to magnetic resonance imaging (MRI for ventricular volumetry. However, the clinical use of cardiac CT requires external validation. Methods: Both cardiac CT and MRI were performed prior to pulmonary valve implantation (PVI in 11 patients (median age, 19 years who had undergone total correction of tetralogy of Fallot during infancy. The simplified contouring method (MRI and semiautomatic 3-dimensional region-growing method (CT were used to measure ventricular volumes. Results: All volumetric indices measured by CT and MRI generally correlated well with each other, except for the left ventricular end-systolic volume index (LV-ESVI, which showed the following correlations with the other indices: the right ventricular end-diastolic volume index (RV-EDVI (r=0.88, p<0.001, the right ventricular end-systolic volume index (RV-ESVI (r=0.84, p=0.001, the left ventricular end-diastolic volume index (LV-EDVI (r=0.90, p=0.001, and the LV-ESVI (r=0.55, p=0.079. While the EDVIs measured by CT were significantly larger than those measured by MRI (median RV-EDVI: 197 mL/m 2 vs. 175 mL/m 2 , p=0.008; median LV-EDVI: 94 mL/m 2 vs. 92 mL/m 2 , p=0.026, no significant differences were found for the RV-ESVI or LV-ESVI. Conclusion: The EDVIs measured by cardiac CT were greater than those measured by MRI, whereas the ESVIs measured by CT and MRI were comparable. The volumetric characteristics of these 2 diagnostic modalities should be taken into account when indications for late PVI after tetralogy of Fallot repair are assessed.

  14. The OMERACT MRI in Arthritis Working Group - Update on Status and Future Research Priorities.

    Science.gov (United States)

    Østergaard, Mikkel; Bird, Paul; Gandjbakhch, Frédérique; Eshed, Iris; Haugen, Ida K; Haavardsholm, Espen A; Lillegraven, Siri; Foltz, Violaine; Glinatsi, Daniel; Peterfy, Charles; Ejbjerg, Bo; Bøyesen, Pernille; Mease, Philip J; Hermann, Kay-Geert; Emery, Paul; Genant, Harry K; Conaghan, Philip G

    2015-12-01

    To provide an update on the status and future research priorities of the Outcome Measures in Rheumatology (OMERACT) magnetic resonance imaging (MRI) in arthritis working group. A summary is provided of the activities of the group within rheumatoid arthritis (RA), psoriatic arthritis (PsA), and osteoarthritis (OA), and its research priorities. The OMERACT RA MRI score (RAMRIS) evaluating bone erosion, bone edema (osteitis), and synovitis is now the standard method of quantifying articular pathology in RA trials. Cartilage loss is another important part of joint damage, and at the OMERACT 12 conference, we provided longitudinal data demonstrating reliability and sensitivity to change of the RAMRIS JSN component score, supporting its use in future clinical trials. The MRI group has previously developed a PsA MRI score (PsAMRIS). At OMERACT 12, PsAMRIS was evaluated in a randomized placebo-controlled trial of patients with PsA, demonstrating the responsiveness and discriminatory ability of applying the PsAMRIS to hands and feet. A hand OA MRI score (HOAMRIS) was introduced at OMERACT 11, and has subsequently been further validated. At OMERACT 12, good cross-sectional interreader reliability, but variable reliability of change scores, were reported. Potential future research areas were identified at the MRI session at OMERACT 12 including assessment of tenosynovitis in RA and enthesitis in PsA and focusing on alternative MRI techniques. MRI has been further developed and validated as an outcome measure in RA, PsA, and OA. The group will continue its efforts to optimize the value of MRI as a robust biomarker in rheumatology clinical trials.

  15. Usefulness of cardiac resonance imaging in Churg-Strauss syndrome.

    Science.gov (United States)

    Nadeau, Pierre L; Kumar, Andreas; O'Connor, Kim; Couture, Christian Y; Bourgault, Christine; Dubois, Michelle; Sénéchal, Mario

    2016-12-01

    : Churg-Strauss syndrome (CSS) is a rare entity that is characterized by widespread vasculitis, which affects both small and medium-sized blood vessels of nearly all organs. More than 50% of these cases have cardiac involvement, which is the major cause of morbidity and mortality. We describe a case of a patient with cardiac biopsy proven CSS, and we discuss the usefulness of cardiovascular MRI for its diagnosis.

  16. Cardiovascular whole-body MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kramer, Harald [Department of Clinical Radiology, University Hospitals Munich - Grosshadern Campus, Ludwig Maxmilians University Munich, Marchioninistr. 15, 81377 Munich (Germany)], E-mail: harald.kramer@med.uni-muenchen.de; Nikolaou, Konstantin; Reiser, Maximilian F. [Department of Clinical Radiology, University Hospitals Munich - Grosshadern Campus, Ludwig Maxmilians University Munich, Marchioninistr. 15, 81377 Munich (Germany)

    2009-06-15

    Cardiovascular diseases still rank number one in mortality statistics in the industrialized world. In these countries the five most common causes of death are associated to atherosclerotic changes of the arterial vasculature. Due to its often long lasting treatment and the possible loss of ability to work atherosclerotic disease constitutes an economic factor which should not be disregarded. Thus screening for atherosclerotic disease seems to be reasonable because as known the potential to influence atherosclerotic changes is higher in an early stage of the disease. Not in every case it is possible to cure the disease but sometimes progression can be controlled and decelerated. Imaging of the arterial vasculature was limited to invasive procedures associated with ionizing radiation for a long time. Non-invasive exams like the 'ankle-brachial-index' (ABI) can indicate the presence of PAOD, an exact localization of the pathologic changes is only possible with imaging methods. For cardiac imaging likewise the only non-invasive exams have been ECG and auscultation. Certainly echocardiography is an excellent technique to access cardiac function but it depends very much on both, the examining physician and the patient. MRI constitutes a non-invasive imaging modality without ionizing radiation offering excellent reproducible image quality.

  17. Cardiovascular whole-body MRI

    International Nuclear Information System (INIS)

    Kramer, Harald; Nikolaou, Konstantin; Reiser, Maximilian F.

    2009-01-01

    Cardiovascular diseases still rank number one in mortality statistics in the industrialized world. In these countries the five most common causes of death are associated to atherosclerotic changes of the arterial vasculature. Due to its often long lasting treatment and the possible loss of ability to work atherosclerotic disease constitutes an economic factor which should not be disregarded. Thus screening for atherosclerotic disease seems to be reasonable because as known the potential to influence atherosclerotic changes is higher in an early stage of the disease. Not in every case it is possible to cure the disease but sometimes progression can be controlled and decelerated. Imaging of the arterial vasculature was limited to invasive procedures associated with ionizing radiation for a long time. Non-invasive exams like the 'ankle-brachial-index' (ABI) can indicate the presence of PAOD, an exact localization of the pathologic changes is only possible with imaging methods. For cardiac imaging likewise the only non-invasive exams have been ECG and auscultation. Certainly echocardiography is an excellent technique to access cardiac function but it depends very much on both, the examining physician and the patient. MRI constitutes a non-invasive imaging modality without ionizing radiation offering excellent reproducible image quality.

  18. [Cardiac sarcoidosis: Diagnosis and therapeutic challenges].

    Science.gov (United States)

    Cohen Aubart, F; Nunes, H; Mathian, A; Haroche, J; Hié, M; Le-Thi Huong Boutin, D; Cluzel, P; Soussan, M; Waintraub, X; Fouret, P; Valeyre, D; Amoura, Z

    2017-01-01

    Sarcoidosis is a granulomatous disorder of unknown cause characterized by non-caseating granuloma in young adults. Cardiac involvement is rare and range from 2 to 75% depending on diagnostic criteria. Cardiac involvement in sarcoidosis may be asymptomatic or may manifest as rhythm/conduction troubles or congestive heart failure. The diagnosis and treatment of cardiac sarcoidosis may be challenging. However, advances have come in recent years from the use of cardiac MRI and 18 FDG-TEP scanner, as well as from the stratification of the risk of ventricular tachycardia/fibrillation. Due to the rarity of the disease, there is no reliable prospective large study to guide therapeutic strategy for cardiac sarcoidosis. Corticosteroids are probably efficacious, in particular in case of atrio-ventricular block or moderate heart failure. Immunosuppressive drugs have not been largely studied but methotrexate could be helpful. In refractory forms, TNF-α antagonists have been used with success. Copyright © 2016 Société Nationale Française de Médecine Interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  19. Clinical implications of increased use of MRI in TIA.

    Science.gov (United States)

    Kvistad, C E; Thomassen, L; Waje-Andreassen, U; Moen, G; Logallo, N; Naess, H

    2013-07-01

    Transient ischemic attack has been redefined as a tissue-based diagnosis and MRI recommended as the preferred imaging modality. We aimed to investigate whether an increased use of MRI leads to a decrease in the proportion of TIA as compared to cerebral infarction. We also sought to see whether DWI-positive patients with transient ischemic symptoms TIA patients in terms of performed diagnostic investigations and clinical characteristics. Patients admitted with cerebral infarction or TIA in the period 2006-2011 were prospectively registered. The use of MRI in patients with transient ischemic symptoms TIA were annually recorded. DWI-positive and DWI-negative patients with transient ischemic symptoms TIA as compared to cerebral infarction decreased from 12.2% in 2006-2008 to 8.3% in 2009-2011 (P = 0.002). DWI-positive patients were more often examined with 24-h Holter monitoring (P TIA definition resulted in a decrease in the proportion of TIA at discharge as compared to cerebral infarction. DWI-positive patients had a more extensive cardiac work-up and were associated with lower age and prior myocardial infarction. © 2012 John Wiley & Sons A/S.

  20. Respiratory and cardiac motion correction in dual gated PET/MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fayad, Hadi; Monnier, Florian [LaTIM, INSERM, UMR 1101, Brest (France); Odille, Freedy; Felblinger, Jacques [INSERM U947, University of Nancy, Nancy (France); Lamare, Frederic [INCIA, UMR5287, CNRS, CHU Bordeaux, Bordeaux (France); Visvikis, Dimitris [LaTIM, INSERM, UMR 1101, Brest (France)

    2015-05-18

    Respiratory and cardiac motion in PET/MR imaging leads to reduced quantitative and qualitative image accuracy. Correction methodologies involve the use of double gated acquisitions which lead to low signal-to-noise ratio (SNR) and to issues concerning the combination of cardiac and respiratory frames. The objective of this work is to use a generalized reconstruction by inversion of coupled systems (GRICS) approach, previously used for PET/MR respiratory motion correction, combined with a cardiac phase signal and a reconstruction incorporated PET motion correction approach in order to reconstruct motion free images from dual gated PET acquisitions. The GRICS method consists of formulating parallel MRI in the presence of patient motion as a coupled inverse problem. Its resolution, using a fixed-point method, allows the reconstructed image to be improved using a motion model constructed from the raw MR data and two respiratory belts. GRICS obtained respiratory displacements are interpolated using the cardiac phase derived from an ECG to model simultaneous cardiac and respiratory motion. Three different volunteer datasets (4DMR acquisitions) were used for evaluation. GATE was used to simulate 4DPET datasets corresponding to the acquired 4DMR images. Simulated data were subsequently binned using 16 cardiac phases (M1) vs diastole only (M2), in combination with 8 respiratory amplitude gates. Respiratory and cardiac motion corrected PET images using either M1 or M2 were compared to respiratory only corrected images and evaluated in terms of SNR and contrast improvement. Significant visual improvements were obtained when correcting simultaneously for respiratory and cardiac motion (using 16 cardiac phase or diastole only) compared to respiratory motion only compensation. Results were confirmed by an associated increased SNR and contrast. Results indicate that using GRICS is an efficient tool for respiratory and cardiac motion correction in dual gated PET/MR imaging.

  1. High frame rate retrospectively triggered Cine MRI for assessment of murine diastolic function

    NARCIS (Netherlands)

    Coolen, Bram F.; Abdurrachim, Desiree; Motaal, Abdallah G.; Nicolay, Klaas; Prompers, Jeanine J.; Strijkers, Gustav J.

    2013-01-01

    To assess left ventricular (LV) diastolic function in mice with Cine MRI, a high frame rate (>60 frames per cardiac cycle) is required. For conventional electrocardiography-triggered Cine MRI, the frame rate is inversely proportional to the pulse repetition time (TR). However, TR cannot be lowered

  2. Acute myocardial infarction: susceptibility-weighted cardiac MRI for the detection of reperfusion haemorrhage at 1.5 T

    International Nuclear Information System (INIS)

    Durighel, G.; Tokarczuk, P.F.; Karsa, A.; Gordon, F.; Cook, S.A.; O'Regan, D.P.

    2016-01-01

    Aim: To assess whether susceptibility-weighted imaging (SWI) provides better image contrast for the detection of haemorrhagic ischaemia–reperfusion injury in the heart. Materials and methods: Thirty patients (all men; mean age 53 years) underwent cardiac magnetic resonance imaging (MRI) within 7 days of primary percutaneous intervention for acute ST elevation myocardial infarction (STEMI). Multiple gradient-echo T2* sequences with magnitude and phase reconstructions were acquired. A high-pass filtered phase map was used to create a mask for the SWI reconstructions. The difference in image contrast was assessed in those patients with microvascular obstruction. A mixed effects regression model was used to test the effect of echo time and reconstruction method on phase and contrast-to-noise ratio (CNR). Medians and interquartile ranges (IQR) are reported. Results: T2* in haemorrhagic infarcts was shorter than in non-haemorrhagic infarcts (33.5 ms [24.9–43] versus 49.9 ms [44.6–67.6]; p=0.0007). The effect of echo time on phase was significant (p<0.0001), as was the effect of haemorrhage on phase (p=0.0016). SWI reconstruction had a significant effect on the CNR at all echo times (echoes 1–5, p<0.0001; echo 6, p=0.01; echo 7, p=0.02). The median echo number at which haemorrhage was first visible was less for SWI compared to source images (echo 2 versus echo 5, p=0.0002). Conclusion: Cardiac SWI improves the contrast between myocardial haemorrhage and the surrounding tissue following STEMI and has potential as a new tool for identifying patients with ischaemia–reperfusion injury. - Highlights: • Cardiac susceptibility-weighted imaging (SWI) is feasible at 1.5T. • Combining phase and modulus data allows blood products to be seen at shorter echo times. • This sequence improves visualisation of reperfusion myocardial haemorrhage.

  3. Gadolinium-DTPA enhanced MRI in myocardial infarction. An experimental and clinical study

    Energy Technology Data Exchange (ETDEWEB)

    Dijkman, P.R.M. van

    1991-10-30

    This thesis focuses on one aspect of cardiac magnetic resonance imaging (MRI) for noninvasive screening of ischemic heart disease: the identification and quantification of acutely infarcted myocardium using gadolineum-diethylene triamine pentaacetic acid (Gd-DTPA) enhanced T1-weighted MRI in a clinical and experimental setting. (author). 296 refs.; 34 figs.; 4 tabs.

  4. Cardiac drugs used in cross-sectional cardiac imaging: what the radiologist needs to know

    International Nuclear Information System (INIS)

    McParland, P.; Nicol, E.D.; Harden, S.P.

    2010-01-01

    The demand for cross-sectional imaging of the heart is increasing dramatically and in many centres these imaging techniques are being performed by radiologists. Although radiologists are familiar with the computed tomography (CT) and magnetic resonance imaging (MRI) techniques to generate high-quality images and with using contrast agents, many are less familiar with administering the drugs necessary to perform CT coronary angiography and cardiac MR reliably. The aim of this article is to give an overview of the indications for and the contraindications to administering cardiac drugs in cross-sectional imaging departments. We also outline the complications that may be encountered and provide advice on how to treat these complications when they occur.

  5. Cine magnetic resonance imaging for evaluation of cardiac structure and flow dynamics in congenital heart disease

    International Nuclear Information System (INIS)

    Akagi, Teiji; Kiyomatsu, Yumi; Ohara, Nobutoshi; Takagi, Junichi; Sato, Noboru; Kato, Hirohisa; Eto, Takaharu.

    1989-01-01

    Cine magnetic resonance imaging (Cine MRI) was performed in 20 patients aged 19 days to 13 years (mean 4.0 years), who had congenital heart disease confirmed at echocardiography or angiography. Prior to cine MRI, gated MRI was performed to evaluate for cardiac structure. Cine MRI was demonstrated by fast low fip angle shot imaging technique with a 30deg flip angle, 15 msec echo time, 30-40 msec pulse repetition time, and 128 x 128 acquisition matrix. Abnormalities of cardiac structure were extremely well defined in all patients by gated MRI. Intracardiac or intravascular blood flow were visualized in 17 (85%) of 20 patients by cine MRI. Left to right shunt flow through ventricular septal defect, atrial septal defect, and endocardial cushion defect were visualized with low signal intensity area. Low intensity jets flow through the site of re-coarctation of the aorta were also visualized. However, the good recording of cine MRI was not obtained because of artifacts in 3 of 20 patients (15%) who had severe congestive heart failure or respiratory arrhythmia. Gated MRI provides excellent visualization of fine structure, and cine MRI can provide high spatial resolution imaging of flow dynamic in a variety of congenital heart disease, noninvasively. (author)

  6. Improving left ventricular segmentation in four-dimensional flow MRI using intramodality image registration for cardiac blood flow analysis.

    Science.gov (United States)

    Gupta, Vikas; Bustamante, Mariana; Fredriksson, Alexandru; Carlhäll, Carl-Johan; Ebbers, Tino

    2018-01-01

    Assessment of blood flow in the left ventricle using four-dimensional flow MRI requires accurate left ventricle segmentation that is often hampered by the low contrast between blood and the myocardium. The purpose of this work is to improve left-ventricular segmentation in four-dimensional flow MRI for reliable blood flow analysis. The left ventricle segmentations are first obtained using morphological cine-MRI with better in-plane resolution and contrast, and then aligned to four-dimensional flow MRI data. This alignment is, however, not trivial due to inter-slice misalignment errors caused by patient motion and respiratory drift during breath-hold based cine-MRI acquisition. A robust image registration based framework is proposed to mitigate such errors automatically. Data from 20 subjects, including healthy volunteers and patients, was used to evaluate its geometric accuracy and impact on blood flow analysis. High spatial correspondence was observed between manually and automatically aligned segmentations, and the improvements in alignment compared to uncorrected segmentations were significant (P  0.05). Our results demonstrate the efficacy of the proposed approach in improving left-ventricular segmentation in four-dimensional flow MRI, and its potential for reliable blood flow analysis. Magn Reson Med 79:554-560, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  7. An interesting case of cryptogenic stroke in a young man due to left ventricular non-compaction: role of cardiac MRI in the accurate diagnosis.

    Science.gov (United States)

    Kannan, Arun; Das, Anindita; Janardhanan, Rajesh

    2014-06-24

    A 28-year-old man arrived for an outpatient cardiac MRI (CMR) study to evaluate cardiac structure. At the age of 24 the patient presented with acute onset expressive aphasia and was diagnosed with ischaemic stroke. Echocardiography at that time was reported as 'apical wall thickening consistent with apical hypertrophic cardiomyopathy'. CMR revealed a moderately dilated left ventricle with abnormal appearance of the left ventricular (LV) apical segments. Further evaluation was consistent with a diagnosis of LV non-compaction (LVNC) cardiomyopathy with a ratio of non-compacted to compacted myocardium measuring 3. There was extensive delayed hyperenhancement signal involving multiple segments representing a significant myocardial scar which is shown to have a prognostic role. Our patient, with no significant cerebrovascular risk factors, would likely have had an embolic stroke. This case demonstrates the role of CMR in accurately diagnosing LVNC in a patient with young stroke where prior echocardiography was non-diagnostic. 2014 BMJ Publishing Group Ltd.

  8. Evaluation of cardiac motion and function by cine magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kondo, Takeshi; Kurokawa, Hiroshi; Anno, Hirofumi

    1992-01-01

    Cardiac cine magnetic resonance imaging (MRI) was studied to evaluate the cardiac motion and function, and a water-stream phantom study was performed to clarify whether it was possible to quantitatively assess the valvular regurgitation flow by the size of the flow void. In normal subjects, the left ventricular (LV) epicardial apex swung up to the base only a few millimeters, and the mitral annulus ring moved about 14 mm as mean value toward the apex during systole. Those motions of mitral annulus ring may contribute to the left atrial filling. The LV longitudinal shortening and torsions were shown by the tagging method. This tagging method was the best method for estimating cardiac motions. Cardiac cine MRI using software including a modified Simpson's method program and a wall motion analysis program was useful for routine LV volumetry and wall motion analysis because it was a simple and reliable method. Our water-stream phantom studies demonstrated that it might be difficult to perform quantitative evaluation of valvular regurgitation flow by using only the size of the flow void without acquiring information relating to the orifice area. (author)

  9. Two-dimensional XD-GRASP provides better image quality than conventional 2D cardiac cine MRI for patients who cannot suspend respiration.

    Science.gov (United States)

    Piekarski, Eve; Chitiboi, Teodora; Ramb, Rebecca; Latson, Larry A; Bhatla, Puneet; Feng, Li; Axel, Leon

    2018-02-01

    Residual respiratory motion degrades image quality in conventional cardiac cine MRI (CCMRI). We evaluated whether a free-breathing (FB) radial imaging CCMRI sequence with compressed sensing reconstruction [extradimensional (e.g. cardiac and respiratory phases) golden-angle radial sparse parallel, or XD-GRASP] could provide better image quality than a conventional Cartesian breath-held (BH) sequence in an unselected population of patients undergoing clinical CCMRI. One hundred one patients who underwent BH and FB imaging in a midventricular short-axis plane at a matching location were included. Visual and quantitative image analysis was performed by two blinded experienced readers, using a five-point qualitative scale to score overall image quality and visual signal-to-noise ratio (SNR) grade, with measures of noise and sharpness. End-diastolic and end-systolic left ventricular areas were also measured and compared for both BH and FB images. Image quality was generally better with the BH cines (overall quality grade for BH vs FB images 4 vs 2.9, p XD-GRASP CCMRI was visually inferior to conventional BH CCMRI in general, it provided improved image quality in the subgroup of patients with respiratory-motion-induced artifacts on BH images.

  10. Job satisfaction and work related variables in Chinese cardiac critical care nurses.

    Science.gov (United States)

    Liu, Yun-E; While, Alison; Li, Shu-Jun; Ye, Wen-Qin

    2015-05-01

    To explore critical care nurses' views of their job satisfaction and the relationship with job burnout, practice environment, coping style, social support, intention to stay in current employment and other work-related variables. Nurse shortage is a global issue, especially in critical care. Job satisfaction is the most frequently cited factor linked to nurses' turnover. A convenience sample of cardiac critical care nurses (n = 215; 97.7% response rate) from 12 large general hospitals in Shanghai was surveyed from December 2010 to March 2011. Over half of the sample reported satisfaction with their jobs. Nurses with 10-20 years of professional experience and those who had taken all their holiday entitlement reported higher levels of job satisfaction. The independent variables of practice environment, intention to stay, emotional exhaustion, personal accomplishment and positive coping style explained about 55% of the variance in job satisfaction. Chinese cardiac critical care nurses' job satisfaction was related to work related variables, which are amenable to managerial action. Our findings highlight the imperative of improving intrinsic and extrinsic rewards, together with the flexibility of work schedules to promote job satisfaction and staff retention. A clinical ladder system is needed to provide promotion opportunities for Chinese nurses. © 2013 John Wiley & Sons Ltd.

  11. Advanced flow MRI: emerging techniques and applications

    International Nuclear Information System (INIS)

    Markl, M.; Schnell, S.; Wu, C.; Bollache, E.; Jarvis, K.; Barker, A.J.; Robinson, J.D.; Rigsby, C.K.

    2016-01-01

    Magnetic resonance imaging (MRI) techniques provide non-invasive and non-ionising methods for the highly accurate anatomical depiction of the heart and vessels throughout the cardiac cycle. In addition, the intrinsic sensitivity of MRI to motion offers the unique ability to acquire spatially registered blood flow simultaneously with the morphological data, within a single measurement. In clinical routine, flow MRI is typically accomplished using methods that resolve two spatial dimensions in individual planes and encode the time-resolved velocity in one principal direction, typically oriented perpendicular to the two-dimensional (2D) section. This review describes recently developed advanced MRI flow techniques, which allow for more comprehensive evaluation of blood flow characteristics, such as real-time flow imaging, 2D multiple-venc phase contrast MRI, four-dimensional (4D) flow MRI, quantification of complex haemodynamic properties, and highly accelerated flow imaging. Emerging techniques and novel applications are explored. In addition, applications of these new techniques for the improved evaluation of cardiovascular (aorta, pulmonary arteries, congenital heart disease, atrial fibrillation, coronary arteries) as well as cerebrovascular disease (intra-cranial arteries and veins) are presented.

  12. MRI of the scrotum. Recommendations of the ESUR Scrotal and Penile Imaging Working Group

    International Nuclear Information System (INIS)

    Tsili, Athina C.; Ntorkou, Alexandra; Bertolotto, Michele; Turgut, Ahmet Tuncay; Dogra, Vikram; Freeman, Simon; Rocher, Laurence; Belfield, Jane; Studniarek, Michal; Derchi, Lorenzo E.; Oyen, Raymond; Ramchandani, Parvati; Secil, Mustafa; Richenberg, Jonathan

    2018-01-01

    The Scrotal and Penile Imaging Working Group (SPI-WG) appointed by the board of the European Society of Urogenital Radiology (ESUR) has produced recommendations for magnetic resonance imaging (MRI) of the scrotum. The SPI-WG searched for original and review articles published before September 2016 using the Pubmed and Medline databases. Keywords used were 'magnetic resonance imaging', 'testis or testicle or testicular', 'scrotum', 'intratesticular', 'paratesticular', 'extratesticular' 'diffusion-weighted', 'dynamic MRI'. Consensus was obtained among the members of the subcommittee. The expert panel proposed recommendations using Oxford Centre for Evidence-Based Medicine 2011 Levels of Evidence. The recommended MRI protocol should include T1-, T2-weighted imaging, diffusion-weighted imaging and dynamic contrast-enhanced MRI. Scrotal MRI can be clinically applied for lesion characterisation (primary), including both intratesticular and paratesticular masses, differentiation between germ-cell and non-germ-cell neoplasms (evolving), characterisation of the histological type of testicular germ cell neoplasms (TGCNs, in selected cases), local staging of TGCNs (primary), acute scrotum (in selected cases), trauma (in selected cases) and undescended testes (primary). The ESUR SPI-WG produced this consensus paper in which the existing literature on MRI of the scrotum is reviewed. The recommendations for the optimal imaging technique and clinical indications are presented. (orig.)

  13. MRI of the scrotum. Recommendations of the ESUR Scrotal and Penile Imaging Working Group

    Energy Technology Data Exchange (ETDEWEB)

    Tsili, Athina C.; Ntorkou, Alexandra [University of Ioannina, Department of Clinical Radiology, Medical School, Ioannina (Greece); Bertolotto, Michele [Uco di Radiologia, Trieste Univ. (Italy); Turgut, Ahmet Tuncay [Ankara Training and Research Hospital, Department of Radiology, Ankara (Turkey); Dogra, Vikram [University of Rochester School of Medicine and Dentistry, Department of Imaging Sciences, Rochester, NY (United States); Freeman, Simon [Plymouth Hospitals NHS Trust, Plymouth (United Kingdom); Rocher, Laurence [Hopitaux Universitaires Paris Sud, APHP, Ecole Doctorale Biosigne, Le Kremlin Bicetre (France); Belfield, Jane [Royal Liverpool University Hospital, Liverpool (United Kingdom); Studniarek, Michal [Medical University of Gdansk, Gdansk (Poland); Derchi, Lorenzo E. [Universita di Genova, Genova (Italy); Oyen, Raymond [KU Leuven, Radiology, Leuven (Belgium); Ramchandani, Parvati [Perelman School of Medicine of the University of Pennsylvania, Philadelphia, PA (United States); Secil, Mustafa [Dokuz Eylul University Faculty of Medicine, Department of Radiology, Izmir (Turkey); Richenberg, Jonathan [Royal Sussex County Hospital Brighton and Brighton and Sussex Medical School, Brighton, Sussex (United Kingdom)

    2018-01-15

    The Scrotal and Penile Imaging Working Group (SPI-WG) appointed by the board of the European Society of Urogenital Radiology (ESUR) has produced recommendations for magnetic resonance imaging (MRI) of the scrotum. The SPI-WG searched for original and review articles published before September 2016 using the Pubmed and Medline databases. Keywords used were 'magnetic resonance imaging', 'testis or testicle or testicular', 'scrotum', 'intratesticular', 'paratesticular', 'extratesticular' 'diffusion-weighted', 'dynamic MRI'. Consensus was obtained among the members of the subcommittee. The expert panel proposed recommendations using Oxford Centre for Evidence-Based Medicine 2011 Levels of Evidence. The recommended MRI protocol should include T1-, T2-weighted imaging, diffusion-weighted imaging and dynamic contrast-enhanced MRI. Scrotal MRI can be clinically applied for lesion characterisation (primary), including both intratesticular and paratesticular masses, differentiation between germ-cell and non-germ-cell neoplasms (evolving), characterisation of the histological type of testicular germ cell neoplasms (TGCNs, in selected cases), local staging of TGCNs (primary), acute scrotum (in selected cases), trauma (in selected cases) and undescended testes (primary). The ESUR SPI-WG produced this consensus paper in which the existing literature on MRI of the scrotum is reviewed. The recommendations for the optimal imaging technique and clinical indications are presented. (orig.)

  14. Extended RF shimming: Sequence-level parallel transmission optimization applied to steady-state free precession MRI of the heart.

    Science.gov (United States)

    Beqiri, Arian; Price, Anthony N; Padormo, Francesco; Hajnal, Joseph V; Malik, Shaihan J

    2017-06-01

    Cardiac magnetic resonance imaging (MRI) at high field presents challenges because of the high specific absorption rate and significant transmit field (B 1 + ) inhomogeneities. Parallel transmission MRI offers the ability to correct for both issues at the level of individual radiofrequency (RF) pulses, but must operate within strict hardware and safety constraints. The constraints are themselves affected by sequence parameters, such as the RF pulse duration and TR, meaning that an overall optimal operating point exists for a given sequence. This work seeks to obtain optimal performance by performing a 'sequence-level' optimization in which pulse sequence parameters are included as part of an RF shimming calculation. The method is applied to balanced steady-state free precession cardiac MRI with the objective of minimizing TR, hence reducing the imaging duration. Results are demonstrated using an eight-channel parallel transmit system operating at 3 T, with an in vivo study carried out on seven male subjects of varying body mass index (BMI). Compared with single-channel operation, a mean-squared-error shimming approach leads to reduced imaging durations of 32 ± 3% with simultaneous improvement in flip angle homogeneity of 32 ± 8% within the myocardium. © 2017 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.

  15. Assessment of congenital heart disease (CHD): Is there a role for fetal magnetic resonance imaging (MRI)?

    Energy Technology Data Exchange (ETDEWEB)

    Manganaro, L. [Department of Radiological Sciences, UMBERTO I Hospital, SAPIENZA University of Rome, Viale del Policlinico 155, 00161 Rome (Italy); Savelli, S. [Department of Radiological Sciences, UMBERTO I Hospital, SAPIENZA University of Rome, Viale del Policlinico 155, 00161 Rome (Italy)], E-mail: sarasavelli@hotmail.it; Di Maurizio, M.; Perrone, A.; Francioso, A.; La Barbera, L.; Totaro, P.; Fierro, F.; Tomei, A.; Coratella, F. [Department of Radiological Sciences, UMBERTO I Hospital, SAPIENZA University of Rome, Viale del Policlinico 155, 00161 Rome (Italy); Giancotti, A. [Department of Gynaecological Sciences, UMBERTO I Hospital, SAPIENZA University of Rome, Viale del Policlinico 155, 00161 Rome (Italy); Ballesio, L. [Department of Radiological Sciences, UMBERTO I Hospital, SAPIENZA University of Rome, Viale del Policlinico 155, 00161 Rome (Italy); Ventriglia, F. [Department of Pediatric Cardiology, UMBERTO I Hospital, SAPIENZA University of Rome, Viale del Policlinico 155, 00161 Rome (Italy)

    2009-10-15

    Purpose: To review our experience with fetal magnetic resonance imaging (MRI) to evaluate congenital heart disease (CHD). Methods: We performed fetal MRI in 32 fetuses with an echocardiographically assessed CHD. Both direct and indirect signs of CHD were investigated. Direct signs considered were: morpho-volumetric abnormalities of the heart; malrotations; ventricular and atrial septal defects; anomalies of the origin, size and course of the great arteries. Indirect signs considered were: difficulty to recognize a 'normal' anatomical structures in the reference projections; increase of the vascular size before a stenosis; hypertrophy of the papillary muscles; cardiomegaly and pericardial effusion. All MRI findings were compared with postnatal or autoptic findings. Results: MRI allowed the CHD to be visualised by direct signs in 17 fetuses, indirect signs in 5 and both direct and indirect signs in 9 fetuses, excluding the prenatal echocardiographic suspect of hypoplastic left heart syndrome in 1 fetus. Postnatal echocardiograms or autoptic findings confirmed a normal heart in 1 fetus and CHD in 31 fetuses including a single cardiac anomaly or syndrome in 19 fetuses, 2 associated cardiac abnormalities in 11 and 3 cardiac anomalies in 1 fetus. However, in 2 fetuses MRI detected a ventricular septal defect successively disclosed by gold standard. Conclusions: MRI is a promising method for further assessment of the cardiovascular pathologies diagnosed by echocardiography, and may be a valuable tool in assessing associated extracardiac anomalies.

  16. Magnetic resonance imaging of implantable cardiac rhythm devices at 3.0 tesla.

    Science.gov (United States)

    Gimbel, J Rod

    2008-07-01

    A relaxation of the prohibition of scanning cardiac rhythm device patients is underway, largely because of the growing experience of safe scanning events at 1.5T. Magnetic resonance imaging (MRI) at 3T is becoming more common and may pose a different risk profile and outcome of MRI of cardiac device patients. No restrictions were placed on pacemaker dependency, region scanned, device type, or manufacturer. Sixteen scans at 3T were performed with an electrophysiologist present on 14 patients with a variety of devices from various manufacturers. An "MRI-S" strategy was used. Multimodal monitoring was required. Device interrogation was performed prior to, immediately after, and 1-3 months after the MRI. For nonpacemaker-dependent device patients, attempts were made to turn all device features off (with OOO programming the goal) conceptually rendering the device "invisible." In pacemaker-dependent patients, the device was programmed to asynchronous mode at highest output for the duration of the scan with the goal of rendering the device conceptually "invulnerable" to MRI effects. The specific absorption rate (SAR) was limited to 2W/kg. All patients were successfully scanned. No arrhythmias were noted. No significant change in the programmed parameters, pacing thresholds, sensing, impedance, or battery parameters was noted. The insertable loop recorder (ILR) recorded prolonged artifactual asystole during MRI. One patient noted chest burning during the scan. Device patients may undergo carefully tailored 3T MRI scans when pre-MRI reprogramming of the device occurs in conjunction with extensive monitoring, supervision, and follow-up.

  17. Comparison of volumetric and functional parameters in simultaneous cardiac PET/MR: feasibility of volumetric assessment with residual activity from prior PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Luecke, C.; Brenneis, B.; Grothoff, M.; Gutberlet, M. [University Leipzig - Heart Center, Department of Diagnostic and Interventional Radiology, Leipzig (Germany); Oppolzer, B.; Werner, P.; Jochimsen, T.; Sattler, B.; Barthel, H.; Sabri, O. [University Hospital Leipzig, Department of Nuclear Medicine, Leipzig (Germany); Foldyna, B. [University Leipzig - Heart Center, Department of Diagnostic and Interventional Radiology, Leipzig (Germany); Massachusetts General Hospital - Harvard Medical School, Cardiac MR PET CT Program, Boston, MA (United States); Lurz, P. [University Leipzig - Heart Center, Clinic for Internal Medicine/Cardiology, Leipzig (Germany); Lehmkuhl, L. [Herz- und Gefaess-Klinik GmbH, Radiologische Klinik, Bad Neustadt (Germany)

    2017-12-15

    To compare cardiac left ventricular (LV) parameters in simultaneously acquired hybrid fluorine-18-fluorodeoxyglucose ([18F] FDG) positron emission tomography/magnetic resonance imaging (PET/MRI) in patients with residual tracer activity of upstream PET/CT. Twenty-nine patients (23 men, age 58±17 years) underwent cardiac PET/MRI either directly after a non-cardiac PET/CT with homogenous cardiac [18F] FDG uptake (n=20) or for viability assessment (n=9). Gated cardiac [18F] FDG PET and cine MR sequences were acquired simultaneously and evaluated blinded to the cross-imaging results. Image quality (IQ), end-diastolic (LVEDV), end-systolic volume (LVESV), ejection fraction (LVEF) and myocardial mass (LVMM) were measured. Pearson correlation and intraclass correlation coefficient (ICC), regression and a Bland-Altman analysis were assessed. Except LVMM, volumetric and functional LV parameters demonstrated high correlations (LVESV: r=0.97, LVEDV: r=0.95, LVEF: r=0.91, LVMM: r=0.87, each p<0.05), but wide limits of agreement (LOA) for LVEDV (-25.3-82.5ml); LVESV (-33.1-72.7ml); LVEF (-18.9-14.8%) and LVMM (-78.2-43.2g). Intra- and interobserver reliability were very high (ICC≥0.95) for all parameters, except for MR-LVEF (ICC=0.87). PET-IQ (0-3) was high (mean: 2.2±0.9) with significant influence on LVMM calculations only. In simultaneously acquired cardiac PET/MRI data, LVEDV, LVESV and LVEF show good agreement. However, the agreement seems to be limited if cardiac PET/MRI follows PET/CT and only the residual activity is used. (orig.)

  18. Value of MRI in diagnostics and evaluation of myositis.

    Science.gov (United States)

    Pipitone, Nicolò

    2016-11-01

    This review aims at covering the role of muscle MRI in supporting the diagnosis of myositis, in aiding to differentiate it from other muscle disorders, and in monitoring myositis patients over time by assessing response to treatment and by discriminating between muscle inflammation and chronic damage. MRI can assist in 'pattern recognition' of muscle involvement across numerous myopathies, including myositis. Novel applications of magnetic resonance such as cardiac MRI, MR elastography and blood oxigenation level-dependent magnetic resonance can shed light on different aspects of myositis and usefully complement conventional MRI in assessing patients with myositis. MRI can guide therapy by determining whether muscle weakness is related to edema (active inflammation) or muscle atrophy/fat replacement (chronic damage). There is a need to better standardize the assessment of MRI findings in myositis to provide defined outcome measures for use in clinical trials. VIDEO ABSTRACT.

  19. Cine dyscontractility index: A novel marker of mechanical dyssynchrony that predicts response to cardiac resynchronization therapy.

    Science.gov (United States)

    Werys, Konrad; Petryka-Mazurkiewicz, Joanna; Błaszczyk, Łukasz; Miśko, Jolanta; Śpiewak, Mateusz; Małek, Łukasz A; Mazurkiewicz, Łukasz; Miłosz-Wieczorek, Barbara; Marczak, Magdalena; Kubik, Agata; Dąbrowska, Agnieszka; Piątkowska-Janko, Ewa; Sawionek, Błażej; Wijesurendra, Rohan; Piechnik, Stefan K; Bogorodzki, Piotr

    2016-12-01

    To investigate whether magnetic resonance imaging (MRI) cine-derived dyssynchrony indices provide additional information compared to conventional tagged MRI (tMRI) acquisitions in heart failure patients undergoing cardiac resynchronization therapy (CRT). Patients scheduled for CRT (n = 52) underwent preprocedure MRI including cine and tMRI acquisitions. Segmental strain curves were calculated for both cine and tMRI to produce a range of standard indices for direct comparison between modalities. We also proposed and evaluated a novel index of "dyscontractility," which detects the presence of focal areas with paradoxically positive circumferential strain. Across conventional strain indices, there was only moderate-to-poor (R = 0.3-0.6) correlation between modalities; eight cine-derived indices showed statistically significant (P cine images (cine dyscontractility index, "CDI") was the single best predictor of clinical response to CRT (area under the curve AUC = 0.81, P Cine-derived strain indices offer potentially new information compared to tMRI. Specifically, the novel CDI is most strongly linked to response to cardiac resynchronization therapy in a contemporary patient cohort. It utilizes readily available MRI data, is relatively straightforward to process, and compares favorably with any conventional tagging index. J. Magn. Reson. Imaging 2016;44:1483-1492. © 2016 International Society for Magnetic Resonance in Medicine.

  20. A 128-channel receive-only cardiac coil for highly accelerated cardiac MRI at 3 Tesla.

    Science.gov (United States)

    Schmitt, Melanie; Potthast, Andreas; Sosnovik, David E; Polimeni, Jonathan R; Wiggins, Graham C; Triantafyllou, Christina; Wald, Lawrence L

    2008-06-01

    A 128-channel receive-only array coil is described and tested for cardiac imaging at 3T. The coil is closely contoured to the body with a "clam-shell" geometry with 68 posterior and 60 anterior elements, each 75 mm in diameter, and arranged in a continuous overlapped array of hexagonal symmetry to minimize nearest neighbor coupling. Signal-to-noise ratio (SNR) and noise amplification for parallel imaging (G-factor) were evaluated in phantom and volunteer experiments. These results were compared to those of commercially available 24-channel and 32-channel coils in routine use for cardiac imaging. The in vivo measurements with the 128-channel coil resulted in SNR gains compared to the 24-channel coil (up to 2.2-fold in the apex). The 128- and 32-channel coils showed similar SNR in the heart, likely dominated by the similar element diameters of these coils. The maximum G-factor values were up to seven times better for a seven-fold acceleration factor (R=7) compared to the 24-channel coil and up to two-fold improved compared to the 32-channel coil. The ability of the 128-channel coil to facilitate highly accelerated cardiac imaging was demonstrated in four volunteers using acceleration factors up to seven-fold (R=7) in a single spatial dimension. Copyright (c) 2008 Wiley-Liss, Inc.

  1. Continuous cardiac troponin I release in Fabry disease.

    Directory of Open Access Journals (Sweden)

    Andreas Feustel

    Full Text Available Fabry disease (FD is a rare lysosomal storage disorder also affecting the heart. The aims of this study were to determine the frequency of cardiac troponin I (cTNI elevation, a sensitive parameter reflecting myocardial damage, in a smaller cohort of FD-patients, and to analyze whether persistent cTNI can be a suitable biomarker to assess cardiac dysfunction in FD.cTNI values were determined at least twice per year in 14 FD-patients (6 males and 8 females regularly followed-up in our centre. The data were related to other parameters of heart function including cardiac magnetic resonance imaging (cMRI.Three patients (21% without specific vascular risk factors other than FD had persistent cTNI-elevations (range 0.05-0.71 ng/ml, normal: <0.01. cMRI disclosed late gadolinium enhancement (LGE in all three individuals with cTNI values ≥0.01, while none of the 11 patients with cTNI <0.01 showed a pathological enhancement (p<0.01. Two subjects with increased cTNI-values underwent coronary angiography, excluding relevant stenoses. A myocardial biopsy performed in one during this procedure demonstrated substantial accumulation of globotriaosylceramide (Gb3 in cardiomyocytes.Continuous cTNI elevation seems to occur in a substantial proportion of patients with FD. The high accordance with LGE, reflecting cardiac dysfunction, suggests that cTNI-elevation can be a useful laboratory parameter for assessing myocardial damage in FD.

  2. Cardiac MRI for myocardial ischemia.

    LENUS (Irish Health Repository)

    Daly, Caroline

    2013-01-01

    Proper assessment of the physiologic impact of coronary artery stenosis on the LV myocardium can affect patient prognosis and treatment decisions. Cardiac magnetic resonance imaging (CMR) assesses myocardial perfusion by imaging the myocardium during a first-pass transit of an intravenous gadolinium bolus, with spatial and temporal resolution substantially higher than nuclear myocardial perfusion imaging. Coupled with late gadolinium enhancement (LGE) imaging for infarction during the same imaging session, CMR with vasodilating stress perfusion imaging can qualitatively and quantitatively assess the myocardial extent of hypoperfusion from coronary stenosis independent of infarcted myocardium. This approach has been validated experimentally, and multiple clinical trials have established its diagnostic robustness when compared to stress single-photon emission computed tomography. In specialized centers, dobutamine stress CMR has been shown to have incremental diagnostic value above stress echocardiography due to its high imaging quality and ability to image the heart with no restriction of imaging window. This paper reviews the technical aspects, diagnostic utility, prognostic values, challenges to clinical adaptation, and future developments of stress CMR imaging.

  3. Visualization of a Small Ventricular Septal Defect at First-pass Contrast-enhanced Cardiac Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Francesco Secchi

    2013-01-01

    Full Text Available Ventricular septal defect (VSD is a congenital heart disease that accounts for up to 40% of all congenital cardiac malformations. VSD is a connection between right and left ventricle, through the ventricular septum. Echocardiography and magnetic resonance imaging (MRI help identify this entity. This case presents a 12-year-old male diagnosed with a small muscular apical VSD of 3 mm in diameter, at echocardiography. Cardiac MRI using first-pass perfusion sequence, combining the right plane of acquisition with a short bolus of contrast material, clearly confirmed the presence of VSD.

  4. MRI of 'brain death'

    International Nuclear Information System (INIS)

    Nishino, Shigeki; Itoh, Takahiko; Tuchida, Shohei; Kinugasa, Kazushi; Asari, Shoji; Nishimoto, Akira; Sanou, Kazuo.

    1990-01-01

    Magnetic resonance imaging (MRI) was undertaken for two patients who suffered from severe cerebrovascular diseases and were clinically brain dead. The MRI system we used was Resona (Yokogawa Medical Systems, superconductive system 0.5 T) and the CT apparatus was Toshiba TCT-300. Initial CT and MRI were undertaken as soon as possible after admission, and repeated sequentially. After diagnosis of brain death, we performed angiography to determine cerebral circulatory arrest, and MRI obtained at the same time was compared with the angiogram and CT. Case 1 was a 77-year-old man who was admitted in an unconscious state. CT and MRI on the second day after hospitalization revealed cerebellar infarction. He was diagnosed as brain dead on day 4. Case 2 was a 35-year-old man. When he was transferred to our hospital, he was in cardiorespiratory arrested. Cardiac resuscitation was successful but no spontaneous respiration appeared. CT and MRI on admission revealed right intracerebral hemorrhage. Angiography revealed cessation of contrast medium in intracranial vessels in both of the patients. We found no 'flow signal void sign' in the bilateral internal carotid and basilar arteries on MRI images in both cases after brain death. MRI, showing us the anatomical changes of the brain, clearly revealed brain herniations, even though only nuclear findings of 'brain tamponade' were seen on CT. But in Case 1, we could not see the infarct lesions in the cerebellum on MR images obtained after brain death. This phenomenon was caused by the whole brain ischemia masking the initial ischemic lesions. We concluded that MRI was useful not only the anatomical display of lesions and brain herniation with high contrast resolution but for obtaining information on cerebral circulation of brain death. (author)

  5. Imaging in blunt cardiac injury: Computed tomographic findings in cardiac contusion and associated injuries.

    Science.gov (United States)

    Hammer, Mark M; Raptis, Demetrios A; Cummings, Kristopher W; Mellnick, Vincent M; Bhalla, Sanjeev; Schuerer, Douglas J; Raptis, Constantine A

    2016-05-01

    Blunt cardiac injury (BCI) may manifest as cardiac contusion or, more rarely, as pericardial or myocardial rupture. Computed tomography (CT) is performed in the vast majority of blunt trauma patients, but the imaging features of cardiac contusion are not well described. To evaluate CT findings and associated injuries in patients with clinically diagnosed BCI. We identified 42 patients with blunt cardiac injury from our institution's electronic medical record. Clinical parameters, echocardiography results, and laboratory tests were recorded. Two blinded reviewers analyzed chest CTs performed in these patients for myocardial hypoenhancement and associated injuries. CT findings of severe thoracic trauma are commonly present in patients with severe BCI; 82% of patients with ECG, cardiac enzyme, and echocardiographic evidence of BCI had abnormalities of the heart or pericardium on CT; 73% had anterior rib fractures, and 64% had pulmonary contusions. Sternal fractures were only seen in 36% of such patients. However, myocardial hypoenhancement on CT is poorly sensitive for those patients with cardiac contusion: 0% of right ventricular contusions and 22% of left ventricular contusions seen on echocardiography were identified on CT. CT signs of severe thoracic trauma are frequently present in patients with severe BCI and should be regarded as indirect evidence of potential BCI. Direct CT findings of myocardial contusion, i.e. myocardial hypoenhancement, are poorly sensitive and should not be used as a screening tool. However, some left ventricular contusions can be seen on CT, and these patients could undergo echocardiography or cardiac MRI to evaluate for wall motion abnormalities. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. ASCI 2010 appropriateness criteria for cardiac computed tomography: a report of the Asian Society of Cardiovascular Imaging Cardiac Computed Tomography and Cardiac Magnetic Resonance Imaging Guideline Working Group.

    Science.gov (United States)

    Tsai, I-Chen; Choi, Byoung Wook; Chan, Carmen; Jinzaki, Masahiro; Kitagawa, Kakuya; Yong, Hwan Seok; Yu, Wei

    2010-02-01

    In Asia, the healthcare system, populations and patterns of disease differ from Western countries. The current reports on the criteria for cardiac CT scans, provided by Western professional societies, are not appropriate for Asian cultures. The Asian Society of Cardiovascular Imaging, the only society dedicated to cardiovascular imaging in Asia, formed a Working Group and invited 23 Technical Panel members representing a variety of Asian countries to rate the 51 indications for cardiac CT in clinical practice in Asia. The indications were rated as 'appropriate' (7-9), 'uncertain' (4-6), or 'inappropriate' (1-3) on a scale of 1-9. The median score was used for the final result if there was no disagreement. The final ratings for indications were 33 appropriate, 14 uncertain and 4 inappropriate. And 20 of them are highly agreed (19 appropriate and 1 inappropriate). Specifically, the Asian representatives considered cardiac CT as an appropriate modality for Kawasaki disease and congenital heart diseases in follow up and in symptomatic patients. In addition, except for some specified conditions, cardiac CT was considered to be an appropriate modality for one-stop shop ischemic heart disease evaluation due to its general appropriateness in coronary, structure and function evaluation. This report is expected to have a significant impact on the clinical practice, research and reimbursement policy in Asia.

  7. The benefits of the Atlas of Human Cardiac Anatomy website for the design of cardiac devices.

    Science.gov (United States)

    Spencer, Julianne H; Quill, Jason L; Bateman, Michael G; Eggen, Michael D; Howard, Stephen A; Goff, Ryan P; Howard, Brian T; Quallich, Stephen G; Iaizzo, Paul A

    2013-11-01

    This paper describes how the Atlas of Human Cardiac Anatomy website can be used to improve cardiac device design throughout the process of development. The Atlas is a free-access website featuring novel images of both functional and fixed human cardiac anatomy from over 250 human heart specimens. This website provides numerous educational tutorials on anatomy, physiology and various imaging modalities. For instance, the 'device tutorial' provides examples of devices that were either present at the time of in vitro reanimation or were subsequently delivered, including leads, catheters, valves, annuloplasty rings and stents. Another section of the website displays 3D models of the vasculature, blood volumes and/or tissue volumes reconstructed from computed tomography and magnetic resonance images of various heart specimens. The website shares library images, video clips and computed tomography and MRI DICOM files in honor of the generous gifts received from donors and their families.

  8. MRI-based morphological modeling, synthesis and characterization of cardiac tissue-mimicking materials.

    Science.gov (United States)

    Kossivas, Fotis; Angeli, S; Kafouris, D; Patrickios, C S; Tzagarakis, V; Constantinides, C

    2012-06-01

    three-dimensional tissue-mimicking models of cardiac anatomy from 2D MR images using rapid prototyping manufacturing processes was developed. For synthesized elastomers, doping strategies with two different concentrations of the MRI contrast agent Dotarem allowed independent and concurrent control of the imaging characteristics (contrast and relaxivity) during the synthetic process for increased contrast agent absorption, with tremendous potential for non-destructive in vivo use and applications to cardiovascular and cerebrovascular diseases.

  9. MRI-based morphological modeling, synthesis and characterization of cardiac tissue-mimicking materials

    International Nuclear Information System (INIS)

    Kossivas, Fotis; Angeli, S; Constantinides, C; Kafouris, D; Patrickios, C S; Tzagarakis, V

    2012-01-01

    three-dimensional tissue-mimicking models of cardiac anatomy from 2D MR images using rapid prototyping manufacturing processes was developed. For synthesized elastomers, doping strategies with two different concentrations of the MRI contrast agent Dotarem allowed independent and concurrent control of the imaging characteristics (contrast and relaxivity) during the synthetic process for increased contrast agent absorption, with tremendous potential for non-destructive in vivo use and applications to cardiovascular and cerebrovascular diseases. (paper)

  10. Novel fMRI working memory paradigm accurately detects cognitive impairment in Multiple Sclerosis

    Science.gov (United States)

    Nelson, Flavia; Akhtar, Mohammad A.; Zúñiga, Edward; Perez, Carlos A.; Hasan, Khader M.; Wilken, Jeffrey; Wolinsky, Jerry S.; Narayana, Ponnada A.; Steinberg, Joel L.

    2016-01-01

    Background Cognitive impairment (CI) cannot be diagnosed by MRI. Functional MRI (fMRI) paradigms such as the immediate/delayed memory task (I/DMT), detect varying degrees of working memory. Preliminary findings using I/DMT, showed differences in Blood Oxygenation Level Dependent (BOLD) activation between impaired (MSCI, n=12) and non-impaired (MSNI, n=9) MS patients. Objectives To confirm CI detection based on I/DMT’ BOLD activation in a larger cohort of MS patients. The role of T2 lesion volume (LV) and EDSS in magnitude of BOLD signal were also sought. Methods Fifty patients [EDSS mean (m) = 3.2, DD m =12 yr., age m =40yr.] underwent the Minimal Assessment of Cognitive Function in MS (MACFIMS) and the I/DMT. Working-memory activation (WMa) represents BOLD signal during DMT minus signal during IMT. CI was based on MACFIMS. Results 10 MSNI, 30 MSCI and 4 borderline patients were included in analyses. ANOVA showed MSNI had significantly greater WMa than MSCI, in the left (L) prefrontal cortex and L supplementary motor area (p = 0.032). Regression analysis showed significant inverse correlations between WMa and T2 LV/EDSS in similar areas (p = 0.005, 0.004 respectively). Conclusion I/DMT-based BOLD activation detects CI in MS, larger studies are needed to confirm these findings. PMID:27613119

  11. Utility of fetal cardiac magnetic resonance imaging to assess fetuses with right aortic arch and right ductus arteriosus.

    Science.gov (United States)

    Dong, Su-Zhen; Zhu, Ming

    2018-06-01

    To evaluate the utility of fetal cardiac magnetic resonance imaging (MRI) to diagnose right aortic arch (RAA) with right ductus arteriosus. This retrospective study included six fetuses with right aortic arch and right ductus arteriosus. The six fetal cases were examined using a 1.5-T magnetic resonance unit. The steady-state free precession (SSFP) and single-shot turbo spin echo (SSTSE) sequences were used to evaluate the fetal heart and airway. The gestational age of the six fetuses ranged from 22 to 35 weeks (mean, 26.5 weeks). The age of the pregnant women ranged from 23 to 40 years (mean 31 years). Fetal cardiac MRI diagnosed the six fetal cases with RAA with right ductus arteriosus correctly. Among the six fetuses, four were associated with other congenital heart defects. In three of six cases, the diagnoses established using prenatal echocardiography (echo) was correct when compared with postnatal diagnosis. Fetal cardiac MRI is a useful complementary tool to assess fetuses with RAA and right ductus arteriosus.

  12. Utility of late gadolinium enhancement in pediatric cardiac MRI

    International Nuclear Information System (INIS)

    Etesami, Maryam; Gilkeson, Robert C.; Rajiah, Prabhakar

    2016-01-01

    Late gadolinium enhancement (LGE) cardiac magnetic resonance (MR) imaging sequence is increasingly used in the evaluation of pediatric cardiovascular disorders, and although LGE might be a normal feature at the sites of previous surgeries, it is pathologically seen as a result of extracellular space expansion, either from acute cell damage or chronic scarring or fibrosis. LGE is broadly divided into ischemic and non-ischemic patterns. LGE caused by myocardial infarction occurs in a vascular distribution and always involves the subendocardial portion, progressively involving the outer regions in a waveform pattern. Non-ischemic cardiomyopathies can have a mid-myocardial (either linear or patchy), subepicardial or diffuse subendocardial distribution. Idiopathic dilated cardiomyopathy can have a linear mid-myocardial pattern, while hypertrophic cardiomyopathy can have fine, patchy enhancement in hypertrophied and non-hypertrophied segments as well as right ventricular insertion points. Myocarditis and sarcoidosis have a mid-myocardial or subepicardial pattern of LGE. Fabry disease typically affects the basal inferolateral segment while Danon disease typically spares the septum. Pericarditis is characterized by diffuse or focal pericardial thickening and enhancement. Thrombus, the most common non-neoplastic cardiac mass, is characterized by absence of enhancement in all sequences, while neoplastic masses show at least some contrast enhancement, depending on the pathology. Regardless of the etiology, presence of LGE is associated with a poor prognosis. In this review, we describe the technical modifications required for performing LGE cardiac MR sequence in children, review and illustrate the patterns of LGE in children, and discuss their clinical significance. (orig.)

  13. Utility of late gadolinium enhancement in pediatric cardiac MRI.

    Science.gov (United States)

    Etesami, Maryam; Gilkeson, Robert C; Rajiah, Prabhakar

    2016-07-01

    Late gadolinium enhancement (LGE) cardiac magnetic resonance (MR) imaging sequence is increasingly used in the evaluation of pediatric cardiovascular disorders, and although LGE might be a normal feature at the sites of previous surgeries, it is pathologically seen as a result of extracellular space expansion, either from acute cell damage or chronic scarring or fibrosis. LGE is broadly divided into ischemic and non-ischemic patterns. LGE caused by myocardial infarction occurs in a vascular distribution and always involves the subendocardial portion, progressively involving the outer regions in a waveform pattern. Non-ischemic cardiomyopathies can have a mid-myocardial (either linear or patchy), subepicardial or diffuse subendocardial distribution. Idiopathic dilated cardiomyopathy can have a linear mid-myocardial pattern, while hypertrophic cardiomyopathy can have fine, patchy enhancement in hypertrophied and non-hypertrophied segments as well as right ventricular insertion points. Myocarditis and sarcoidosis have a mid-myocardial or subepicardial pattern of LGE. Fabry disease typically affects the basal inferolateral segment while Danon disease typically spares the septum. Pericarditis is characterized by diffuse or focal pericardial thickening and enhancement. Thrombus, the most common non-neoplastic cardiac mass, is characterized by absence of enhancement in all sequences, while neoplastic masses show at least some contrast enhancement, depending on the pathology. Regardless of the etiology, presence of LGE is associated with a poor prognosis. In this review, we describe the technical modifications required for performing LGE cardiac MR sequence in children, review and illustrate the patterns of LGE in children, and discuss their clinical significance.

  14. Segmentation of left ventricle myocardium in porcine cardiac cine MR images using a hybrid of fully convolutional neural networks and convolutional LSTM

    Science.gov (United States)

    Zhang, Dongqing; Icke, Ilknur; Dogdas, Belma; Parimal, Sarayu; Sampath, Smita; Forbes, Joseph; Bagchi, Ansuman; Chin, Chih-Liang; Chen, Antong

    2018-03-01

    In the development of treatments for cardiovascular diseases, short axis cardiac cine MRI is important for the assessment of various structural and functional properties of the heart. In short axis cardiac cine MRI, Cardiac properties including the ventricle dimensions, stroke volume, and ejection fraction can be extracted based on accurate segmentation of the left ventricle (LV) myocardium. One of the most advanced segmentation methods is based on fully convolutional neural networks (FCN) and can be successfully used to do segmentation in cardiac cine MRI slices. However, the temporal dependency between slices acquired at neighboring time points is not used. Here, based on our previously proposed FCN structure, we proposed a new algorithm to segment LV myocardium in porcine short axis cardiac cine MRI by incorporating convolutional long short-term memory (Conv-LSTM) to leverage the temporal dependency. In this approach, instead of processing each slice independently in a conventional CNN-based approach, the Conv-LSTM architecture captures the dynamics of cardiac motion over time. In a leave-one-out experiment on 8 porcine specimens (3,600 slices), the proposed approach was shown to be promising by achieving average mean Dice similarity coefficient (DSC) of 0.84, Hausdorff distance (HD) of 6.35 mm, and average perpendicular distance (APD) of 1.09 mm when compared with manual segmentations, which improved the performance of our previous FCN-based approach (average mean DSC=0.84, HD=6.78 mm, and APD=1.11 mm). Qualitatively, our model showed robustness against low image quality and complications in the surrounding anatomy due to its ability to capture the dynamics of cardiac motion.

  15. Updating working memory in aircraft noise and speech causes different fMRI activations

    OpenAIRE

    Sætrevik, Bjørn; Sörqvist, Patrik

    2014-01-01

    The present study used fMRI/BOLD neuroimaging to investigate how visual-verbal working memory is updated when exposed to three different background-noise conditions: speech noise, aircraft noise and silence. The number-updating task that was used can distinguish between ?substitution processes,? which involve adding new items to the working memory representation and suppressing old items, and ?exclusion processes,? which involve rejecting new items and maintaining an intact memory set. The cu...

  16. Comparison of left ventricular function assessment between echocardiography and MRI in Duchenne muscular dystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Buddhe, Sujatha; Lewin, Mark; Olson, Aaron; Soriano, Brian D. [University of Washington School of Medicine and Seattle Children' s Hospital, Division of Cardiology, Department of Pediatrics, Seattle, WA (United States); Ferguson, Mark [University of Washington School of Medicine and Seattle Children' s Hospital, Department of Radiology, Seattle, WA (United States)

    2016-09-15

    Cardiomyopathy in Duchenne muscular dystrophy (DMD) is associated with death in approximately 40% of patients. Echocardiography is routinely used to assess left ventricular (LV) function; however, it has limitations in these patients. We compared echocardiographic measures of cardiac function assessment to cardiac MRI. We included children and young adults with DMD who had MRI performed between January 2010 and July 2015. We measured echocardiographic and MRI parameters of function assessment, including strain. Presence of late gadolinium enhancement (LGE) was assessed by MRI. Subjects were divided into two groups based on MRI left ventricular ejection fraction (LVEF): group I, LVEF ≥55% and group II, LVEF <55%. We included 41 studies in 33 subjects, with 25 in group I and 16 in group II. Mean age of subjects was 13.6 ± 2.8 years and mean duration between echocardiogram and MRI was 7.6 ± 4.1 months. Only 8 of 16 (50%) patients in group II had diminished function on echocardiogram. Echocardiographic images were suboptimal in 16 subjects (39%). Overall, echocardiographic parameters had weak correlation with MRI-derived ejection fraction percentage. MRI-derived myocardial strain assessment has better correlation with MRI ejection fraction as compared to echocardiography-derived strain parameters. Echocardiography-based ventricular functional assessment has weak correlation with MRI parameters in children and young adults with Duchenne muscular dystrophy. While this correlation improves in the subset of subjects with adequate echocardiographic image quality, it remains modest and potentially suboptimal for clinical management. Accordingly, we conclude that MRI should be performed routinely and early in children with DMD, not only for LGE imaging but also for functional assessment. (orig.)

  17. Comparison of left ventricular function assessment between echocardiography and MRI in Duchenne muscular dystrophy

    International Nuclear Information System (INIS)

    Buddhe, Sujatha; Lewin, Mark; Olson, Aaron; Soriano, Brian D.; Ferguson, Mark

    2016-01-01

    Cardiomyopathy in Duchenne muscular dystrophy (DMD) is associated with death in approximately 40% of patients. Echocardiography is routinely used to assess left ventricular (LV) function; however, it has limitations in these patients. We compared echocardiographic measures of cardiac function assessment to cardiac MRI. We included children and young adults with DMD who had MRI performed between January 2010 and July 2015. We measured echocardiographic and MRI parameters of function assessment, including strain. Presence of late gadolinium enhancement (LGE) was assessed by MRI. Subjects were divided into two groups based on MRI left ventricular ejection fraction (LVEF): group I, LVEF ≥55% and group II, LVEF <55%. We included 41 studies in 33 subjects, with 25 in group I and 16 in group II. Mean age of subjects was 13.6 ± 2.8 years and mean duration between echocardiogram and MRI was 7.6 ± 4.1 months. Only 8 of 16 (50%) patients in group II had diminished function on echocardiogram. Echocardiographic images were suboptimal in 16 subjects (39%). Overall, echocardiographic parameters had weak correlation with MRI-derived ejection fraction percentage. MRI-derived myocardial strain assessment has better correlation with MRI ejection fraction as compared to echocardiography-derived strain parameters. Echocardiography-based ventricular functional assessment has weak correlation with MRI parameters in children and young adults with Duchenne muscular dystrophy. While this correlation improves in the subset of subjects with adequate echocardiographic image quality, it remains modest and potentially suboptimal for clinical management. Accordingly, we conclude that MRI should be performed routinely and early in children with DMD, not only for LGE imaging but also for functional assessment. (orig.)

  18. Relationship between cardiac function and resting cerebral blood flow: MRI measurements in healthy elderly subjects.

    Science.gov (United States)

    Henriksen, Otto M; Jensen, Lars T; Krabbe, Katja; Larsson, Henrik B W; Rostrup, Egill

    2014-11-01

    Although both impaired cardiac function and reduced cerebral blood flow are associated with ageing, current knowledge of the influence of cardiac function on resting cerebral blood flow (CBF) is limited. The aim of this study was to investigate the potential effects of cardiac function on CBF. CBF and cardiac output were measured in 31 healthy subjects 50-75 years old using magnetic resonance imaging techniques. Mean values of CBF, cardiac output and cardiac index were 43.6 ml per 100 g min(-1), 5.5 l min(-1) and 2.7 l min(-1) m(-2), respectively, in males, and 53.4 ml per 100 g min(-1), 4.3 l min(-1) and 2.4 l min(-1) m(-2), respectively, in females. No effects of cardiac output or cardiac index on CBF or structural signs of brain ageing were observed. However, fractional brain flow defined as the ratio of total brain flow to cardiac output was inversely correlated with cardiac index (r(2) = 0.22, P = 0.008) and furthermore lower in males than in females (8.6% versus 12.5%, P = 0.003). Fractional brain flow was also inversely correlated with cerebral white matter lesion grade, although this effect was not significant when adjusted for age. Frequency analysis of heart rate variability showed a gender-related inverse association of increased low-to-high-frequency power ratio with CBF and fractional brain flow. The findings do not support a direct effect of cardiac function on CBF, but demonstrates gender-related differences in cardiac output distribution. We propose fractional brain flow as a novel index that may be a useful marker of adequate brain perfusion in the context of ageing as well as cardiovascular disease. © 2013 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  19. Cardiac imaging. A multimodality approach

    International Nuclear Information System (INIS)

    Thelen, Manfred; Erbel, Raimund; Kreitner, Karl-Friedrich; Barkhausen, Joerg

    2009-01-01

    An excellent atlas on modern diagnostic imaging of the heart Written by an interdisciplinary team of experts, Cardiac Imaging: A Multimodality Approach features an in-depth introduction to all current imaging modalities for the diagnostic assessment of the heart as well as a clinical overview of cardiac diseases and main indications for cardiac imaging. With a particular emphasis on CT and MRI, the first part of the atlas also covers conventional radiography, echocardiography, angiography and nuclear medicine imaging. Leading specialists demonstrate the latest advances in the field, and compare the strengths and weaknesses of each modality. The book's second part features clinical chapters on heart defects, endocarditis, coronary heart disease, cardiomyopathies, myocarditis, cardiac tumors, pericardial diseases, pulmonary vascular diseases, and diseases of the thoracic aorta. The authors address anatomy, pathophysiology, and clinical features, and evaluate the various diagnostic options. Key features: - Highly regarded experts in cardiology and radiology off er image-based teaching of the latest techniques - Readers learn how to decide which modality to use for which indication - Visually highlighted tables and essential points allow for easy navigation through the text - More than 600 outstanding images show up-to-date technology and current imaging protocols Cardiac Imaging: A Multimodality Approach is a must-have desk reference for cardiologists and radiologists in practice, as well as a study guide for residents in both fields. It will also appeal to cardiac surgeons, general practitioners, and medical physicists with a special interest in imaging of the heart. (orig.)

  20. MRI assessment of thoracic stent grafts after emergency implantation in multi trauma patients: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Rasche, Volker [University Hospital Ulm, Department of Internal Medicine II, Ulm (Germany); University Hospital Ulm, University of Ulm, Department of Internal Medicine II, Ulm (Germany); Oberhuber, Alexander; Orend, Karl-Heinz [University Hospital Ulm, Department of Vascular and Thoracic Surgery, Ulm (Germany); Trumpp, Stephan [University Hospital Ulm, Department of Internal Medicine II, Ulm (Germany); University Hospital Ulm, Department of Vascular and Thoracic Surgery, Ulm (Germany); Bornstedt, Axel; Merkle, Nico; Rottbauer, Wolfgang [University Hospital Ulm, Department of Internal Medicine II, Ulm (Germany); Hoffmann, Martin [University Hospital Ulm, Department of Diagnostic and Interventional Radiology, Ulm (Germany)

    2011-07-15

    To evaluate the feasibility of MRI for static and dynamic assessment of the deployment of thoracic aortic stent grafts after emergency implantation in trauma patients. Twenty patients initially presenting with a rupture of the thoracic aorta were enrolled in this study. All patients underwent thoracic endovascular aortic repair (TEVAR). The deployment of the implanted stent graft was assessed by CTA and MRI, comprising the assessment of the aortic arch with and without contrast agent, and the assessment of the motion of the stent graft over the cardiac cycle. The stent graft geometry and motion over the cardiac cycle were assessable by MRI in all patients. Flow-mediated signal variations in areas of flow acceleration could be well visualised. No statistically significant differences in stent-graft diameters were observed between CT and MRI measurements. MRI appears to be a valuable tool for the assessment of thoracic stent grafts. It shows similar performance in the accurate assessment of stent-graft dimensions to the current gold standard CTA. Its capability of providing additional functional information and the lack of ionising radiation and nephrotoxic contrast agents may make MRI a valuable tool for monitoring patients after TEVAR. (orig.)

  1. Task-related changes in degree centrality and local coherence of the posterior cingulate cortex after major cardiac surgery in older adults.

    Science.gov (United States)

    Browndyke, Jeffrey N; Berger, Miles; Smith, Patrick J; Harshbarger, Todd B; Monge, Zachary A; Panchal, Viral; Bisanar, Tiffany L; Glower, Donald D; Alexander, John H; Cabeza, Roberto; Welsh-Bohmer, Kathleen; Newman, Mark F; Mathew, Joseph P

    2018-02-01

    Older adults often display postoperative cognitive decline (POCD) after surgery, yet it is unclear to what extent functional connectivity (FC) alterations may underlie these deficits. We examined for postoperative voxel-wise FC changes in response to increased working memory load demands in cardiac surgery patients and nonsurgical controls. Older cardiac surgery patients (n = 25) completed a verbal N-back working memory task during MRI scanning and cognitive testing before and 6 weeks after surgery; nonsurgical controls with cardiac disease (n = 26) underwent these assessments at identical time intervals. We measured postoperative changes in degree centrality, the number of edges attached to a brain node, and local coherence, the temporal homogeneity of regional functional correlations, using voxel-wise graph theory-based FC metrics. Group × time differences were evaluated in these FC metrics associated with increased N-back working memory load (2-back > 1-back), using a two-stage partitioned variance, mixed ANCOVA. Cardiac surgery patients demonstrated postoperative working memory load-related degree centrality increases in the left dorsal posterior cingulate cortex (dPCC; p < .001, cluster p-FWE < .05). The dPCC also showed a postoperative increase in working memory load-associated local coherence (p < .001, cluster p-FWE < .05). dPCC degree centrality and local coherence increases were inversely associated with global cognitive change in surgery patients (p < .01), but not in controls. Cardiac surgery patients showed postoperative increases in working memory load-associated degree centrality and local coherence of the dPCC that were inversely associated with postoperative global cognitive outcomes and independent of perioperative cerebrovascular damage. © 2017 Wiley Periodicals, Inc.

  2. Large-Animal Biventricular Working Heart Perfusion System with Low Priming Volume-Comparison between in vivo and ex vivo Cardiac Function.

    Science.gov (United States)

    Abicht, Jan-Michael; Mayr, Tanja Axinja Jelena; Jauch, Judith; Guethoff, Sonja; Buchholz, Stefan; Reichart, Bruno; Bauer, Andreas

    2018-01-01

    Existing large-animal, ex vivo, cardiac perfusion models are restricted in their ability to establish an ischemia/reperfusion condition as seen in cardiac surgery or transplantation. Other working heart systems only challenge one ventricle or require a substantially larger priming volume. We describe a novel biventricular cardiac perfusion system with reduced priming volume. Juvenile pig hearts were cardiopleged, explanted, and reperfused ex vivo after 150 minutes of cold ischemia. Autologous whole blood was used as perfusate (minimal priming volume 350 mL). After 15 minutes of Langendorff perfusion (LM), the system was switched into a biventricular working mode (WM) and studied for 3 hours. During reperfusion, complete unloading of both ventricles and constant-pressure coronary perfusion was achieved. During working mode perfusion, the preload and afterload pressure of both ventricles was controlled within the targeted physiologic range. Functional parameters such as left ventricular work index were reduced in ex vivo working mode (in vivo: 787 ± 186 vs. 1 h WM 498 ± 66 mm Hg·mL/g·min; p  hours while functional and blood parameters are easily accessible. Moreover, because of the minimal priming volume, the novel ex vivo cardiac perfusion circuit allows for autologous perfusion, using the limited amount of blood available from the organ donating animal. Georg Thieme Verlag KG Stuttgart · New York.

  3. Imaging of the myocardium using {sup 18}F-FDG-PET/MRI

    Energy Technology Data Exchange (ETDEWEB)

    Ferda, Jiří, E-mail: ferda@fnplzen.cz [Clinic of the Imaging Methods, University Hospital Plzen, Alej Svobody 80, 304 60 Plzeň (Czech Republic); Hromádka, Milan, E-mail: hromadkam@fnplzen.cz [Department of Cardiology, University Hospital Plzen, Alej Svobody 80, 304 60 Plzeň (Czech Republic); Baxa, Jan, E-mail: baxaj@fnplzen.cz [Clinic of the Imaging Methods, University Hospital Plzen, Alej Svobody 80, 304 60 Plzeň (Czech Republic)

    2016-10-15

    Highlights: • The natural combination of the metabolic and structural information is the most important strenghtof myocardial PET/MRI. • Metabolic conversion to glycolysis is needed in the assesment ov the viable myocardium. • Metabolic conversion to the fatty acid metabolism is the crucial in the assesment of the ischemic memory and myocardial inflammation. - Abstract: The introduction of the integrated hybrid PET/MRI equipment creates the possibility to perform PET and MRI simultaneously. Depending on the clinical question, the metabolic conversion to glycolytic activity or beta-oxidation is performed before the application of FDG. Since FDG aids to evaluate the energetic metabolism of the myocytes and myocardial MRI reaches the imaging capabilities of perfusion and tissue characterization in the daily routine, FDG-PET/MRI looks to be a promising method of PET/MRI exploitation in cardiac imaging. When myocardial FDG uptake should be evaluated in association with the perfusion distribution, the cross-evaluation of FDG accumulation distribution and perfusion distribution pattern is necessary. The different scenarios may be used in the assessment of myocardium, the conversion to glycolytic activity is used in the imaging of the viable myocardium, but the glycolytic activity suppression might be used in the indications of the identification of injured myocardium by ischemia or inflammation. FDG-PET/MRI might aid to answer the clinical tasks according to the structure, current function and possibilities to improve the function in ischemic heart disease or to display the extent or activity of myocardial inflammation in sarcoidosis. The tight coupling between metabolism, perfusion and contractile function offers an opportunity for the simultaneous assessment of cardiac performance using one imaging modality.

  4. Police work stressors and cardiac vagal control.

    Science.gov (United States)

    Andrew, Michael E; Violanti, John M; Gu, Ja K; Fekedulegn, Desta; Li, Shengqiao; Hartley, Tara A; Charles, Luenda E; Mnatsakanova, Anna; Miller, Diane B; Burchfiel, Cecil M

    2017-09-10

    This study examines relationships between the frequency and intensity of police work stressors and cardiac vagal control, estimated using the high frequency component of heart rate variability (HRV). This is a cross-sectional study of 360 officers from the Buffalo New York Police Department. Police stress was measured using the Spielberger police stress survey, which includes exposure indices created as the product of the self-evaluation of how stressful certain events were and the self-reported frequency with which they occurred. Vagal control was estimated using the high frequency component of resting HRV calculated in units of milliseconds squared and reported in natural log scale. Associations between police work stressors and vagal control were examined using linear regression for significance testing and analysis of covariance for descriptive purposes, stratified by gender, and adjusted for age and race/ethnicity. There were no significant associations between police work stressor exposure indices and vagal control among men. Among women, the inverse associations between the lack of support stressor exposure and vagal control were statistically significant in adjusted models for indices of exposure over the past year (lowest stressor quartile: M = 5.57, 95% CI 5.07 to 6.08, and highest stressor quartile: M = 5.02, 95% CI 4.54 to 5.51, test of association from continuous linear regression of vagal control on lack of support stressor β = -0.273, P = .04). This study supports an inverse association between lack of organizational support and vagal control among female but not male police officers. © 2017 Wiley Periodicals, Inc.

  5. Postmortem cardiac imaging in fetuses and children

    International Nuclear Information System (INIS)

    Taylor, Andrew M.; Arthurs, Owen J.; Sebire, Neil J.

    2015-01-01

    Fetal and pediatric cardiac autopsies have a crucial role in the counseling of parents with regard to both the cause of death of their child and the implications of such findings for future pregnancies, as well as for quality assurance of antenatal screening programs and antemortem diagnostic procedures. Postmortem imaging allows an opportunity to investigate the heart in situ prior to dissection, and both postmortem CT and postmortem MRI have shown excellent accuracy in detecting the majority of clinically significant cardiac lesions in the perinatal and pediatric population. As less-invasive autopsy becomes increasingly popular, clinical guidelines for maximal diagnostic yield in specific circumstances can be developed. (orig.)

  6. Postmortem cardiac imaging in fetuses and children

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Andrew M. [Great Ormond Street Hospital for Children NHS Foundation Trust, Cardiorespiratory Division, Level 7, Old Nurses Home, London (United Kingdom); UCL Institute of Cardiovascular Science, London (United Kingdom); Arthurs, Owen J. [Great Ormond Street Hospital for Children NHS Foundation Trust, Department of Radiology, London (United Kingdom); UCL Institute of Cardiovascular Science, London (United Kingdom); Sebire, Neil J. [UCL Institute of Cardiovascular Science, London (United Kingdom); Great Ormond Street Hospital for Children NHS Foundation Trust, Department of Histopathology, London (United Kingdom)

    2015-04-01

    Fetal and pediatric cardiac autopsies have a crucial role in the counseling of parents with regard to both the cause of death of their child and the implications of such findings for future pregnancies, as well as for quality assurance of antenatal screening programs and antemortem diagnostic procedures. Postmortem imaging allows an opportunity to investigate the heart in situ prior to dissection, and both postmortem CT and postmortem MRI have shown excellent accuracy in detecting the majority of clinically significant cardiac lesions in the perinatal and pediatric population. As less-invasive autopsy becomes increasingly popular, clinical guidelines for maximal diagnostic yield in specific circumstances can be developed. (orig.)

  7. The OMERACT MRI in Arthritis Working Group - Update on Status and Future Research Priorities

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Bird, Paul; Gandjbakhch, Frédérique

    2015-01-01

    OBJECTIVE: To provide an update on the status and future research priorities of the Outcome Measures in Rheumatology (OMERACT) magnetic resonance imaging (MRI) in arthritis working group. METHODS: A summary is provided of the activities of the group within rheumatoid arthritis (RA), psoriatic...

  8. Diagnostic value of electron-beam computed tomography (EBT). I. cardiac applications

    International Nuclear Information System (INIS)

    Enzweiler, C.N.H.; Lembcke, A.; Rogalla, P.; Taupitz, M.; Wiese, T.H.; Hammm, B.; Becker, C.R.; Reiser, M.F.; Felix, R.; Knollmann, F.D.; Georgi, M.; Weisser, G.; Lehmann, K.J.

    2004-01-01

    Electron beam tomography (EBT) directly competes with other non-invasive imaging modalities, such as multislice computed tomography, magnetic resonance imaging, and echocardiography, in the diagnostic assessment of cardiac diseases. EBT is the gold standard for the detection and quantification of coronary calcium as a preclinical sign of coronary artery disease (CAD). Its standardized examination protocols and the broad experience with this method favor EBT. First results with multislice CT indicate that this new technology may be equivalent to EBT for coronary calcium studies. The principal value of CT-based coronary calcium measurements continues to be an issue of controversy amongst radiologists and cardiologists due to lack of prospective randomized trials. Coronary angiography with EBT is characterized by a high negative predictive value and, in addition, may be indicated in some patients with manifest CAD. It remains to be shown whether coronary angiography with multislice CT is reliable and accurate enough to be introduced into the routine work-up, to replace some of the many strictly diagnostic coronary catheterizations in Germany and elsewhere. Assessment of coronary stent patency with EBT is associated with several problems and in our opinion cannot be advocated as a routine procedure. EBT may be recommended for the evaluation of coronary bypasses to look for bypass occlusions and significant stenoses, which, however, can be equally well achieved with multislice CT. Quantification of myocardial perfusion with EBT could not replace MRI or other modalities in this field. EBT has proven to be accurate, reliable and in some instances equivalent to MRI, which is the gold standard for the quantitative and qualitative evaluation of cardiac function. Some disadvantages not the least of which is the limited distribution of electron beam scanners, favor MRI for functional assessment of the heart. (orig.) [de

  9. Analysis of chronic aortic regurgitation by 2D and 3D echocardiography and cardiac MRI

    DEFF Research Database (Denmark)

    Stoebe, Stephan; Metze, Michael; Jurisch, Daniel

    2018-01-01

    ) were assessed retrospectively by 2D, 3D echocardiography and cMRI in 55 chronic AR patients. Semi-quantitative parameters were assessed by 2D echocardiography. RESULTS: 22 (40%) patients had mild, 25 (46%) moderate and 8 (14%) severe AR. The quantitative volumetric approach was feasible using 2D, 3D...... echocardiography and cMRI, whereas the feasibility of semi-quantitative parameters varied considerably. LV volume (LVEDV, LVESV, SVtot) analyses showed good correlations between the different imaging modalities, although significantly increased LV volumes were assessed by cMRI. RVol was significantly different...... between 2D/3D echocardiography and 2D echocardiography/cMRI but was not significantly different between 3D echocardiography/cMRI. RF was not statistically different between 2D echocardiography/cMRI and 3D echocardiography/cMRI showing poor correlations (r

  10. Early postoperative remodelling following repair of tetralogy of Fallot utilising unsedated cardiac magnetic resonance: a pilot study.

    Science.gov (United States)

    DiLorenzo, Michael P; Goldmuntz, Elizabeth; Nicolson, Susan C; Fogel, Mark A; Mercer-Rosa, Laura

    2018-05-01

    IntroductionThe right ventricular adaptations early after surgery in infants with tetralogy of Fallot are important to understand the changes that occur later on in life; this physiology has not been fully delineated. We sought to assess early postoperative right ventricular remodelling in patients with tetralogy of Fallot by cardiac MRI.Materials and methodSubjects with tetralogy of Fallot under 1 year of age were recruited following complete surgical repair for tetralogy of Fallot. Protocol-based cardiac MRI to assess anatomy, function, and flows was performed before hospital discharge using the feed and sleep technique, an unsedated imaging technique. MRI was completed in 16 subjects at a median age of 77 days (interquartile range 114). There was normal ventricular ejection fraction and indexed right ventricular end-diastolic volume (48±13 cc/m2), but elevated right ventricular mass (z score 6.2±2.4). Subjects requiring a transannular patch or right ventricle to pulmonary artery conduit had moderate pulmonary insufficiency (regurgitant fraction 27±16%).DiscussionEarly right ventricular remodelling after surgical repair for tetralogy of Fallot is characterised by significant pulmonary regurgitation, right ventricular hypertrophy, and lack of dilation. Performing cardiac MRI using the feed and sleep technique is feasible in infants younger than 5 months. These results might open new avenues to study longitudinal right ventricular changes in tetralogy of Fallot and to further explore the utility of unsedated MRI in patients with other types of CHDs.

  11. [Role of cardiac magnetic resonance in cardiac involvement of Fabry disease].

    Science.gov (United States)

    Serra, Viviana M; Barba, Miguel Angel; Torrá, Roser; Pérez De Isla, Leopoldo; López, Mónica; Calli, Andrea; Feltes, Gisela; Torras, Joan; Valverde, Victor; Zamorano, José L

    2010-09-04

    Fabry disease is a hereditary disorder. Clinical manifestations are multisystemic. The majority of the patients remain undiagnosed until late in life, when alterations could be irreversible. Early detection of cardiac symptoms is of major interest in Fabry's disease (FD) in order to gain access to enzyme replacement therapy. Echo-Doppler tissular imaging (TDI) has been used as a cardiologic early marker in FD. This study is intended to determine whether the cardiac magnetic resonance is as useful tool as TDI for the early detection of cardiac affectation in FD. Echocardiography, tissue Doppler and Cardio magnetic resonance was performed in 20 patients with confirmed Fabry Disease. Left ventricular hypertrophy was defined as septum and left ventricular posterior wall thickness ≥12 mm. An abnormal TDI velocity was defined as (Sa), (Ea) and/or (Aa) velocities gadolinium-enhanced images sequences were obtained using magnetic resonance. Twenty patients included in the study were divided into three groups: 1. Those without left ventricular hypertrophy nor tissue Doppler impairment 2. Those without left ventricular hypertrophy and tissue Doppler impairment 3. Those with left ventricular hypertrophy and Tissue Doppler impairment. Late gadolinium enhancement was found in only one patient, who has already altered DTI and LVH. Tissue Doppler imaging (TDI) is the only diagnostic tool able to provide early detection of cardiac affectation in patients with FD. Magnetic resonance provides information of the disease severity in patients with LVH, but can not be used as an early marker of cardiac disease in patients with FD. However MRI could be of great value for diagnostic stratification. Copyright © 2009 Elsevier España, S.L. All rights reserved.

  12. The OMERACT Rheumatoid Arthritis Magnetic Resonance Imaging (MRI) Scoring System: Updated Recommendations by the OMERACT MRI in Arthritis Working Group.

    Science.gov (United States)

    Østergaard, Mikkel; Peterfy, Charles G; Bird, Paul; Gandjbakhch, Frédérique; Glinatsi, Daniel; Eshed, Iris; Haavardsholm, Espen A; Lillegraven, Siri; Bøyesen, Pernille; Ejbjerg, Bo; Foltz, Violaine; Emery, Paul; Genant, Harry K; Conaghan, Philip G

    2017-11-01

    The Outcome Measures in Rheumatology (OMERACT) Rheumatoid Arthritis (RA) Magnetic Resonance Imaging (MRI) scoring system (RAMRIS), evaluating bone erosion, bone marrow edema/osteitis, and synovitis, was introduced in 2002, and is now the standard method of objectively quantifying inflammation and damage by MRI in RA trials. The objective of this paper was to identify subsequent advances and based on them, to provide updated recommendations for the RAMRIS. MRI studies relevant for RAMRIS and technical and scientific advances were analyzed by the OMERACT MRI in Arthritis Working Group, which used these data to provide updated considerations on image acquisition, RAMRIS definitions, and scoring systems for the original and new RA pathologies. Further, a research agenda was outlined. Since 2002, longitudinal studies and clinical trials have documented RAMRIS variables to have face, construct, and criterion validity; high reliability and sensitivity to change; and the ability to discriminate between therapies. This has enabled RAMRIS to demonstrate inhibition of structural damage progression with fewer patients and shorter followup times than has been possible with conventional radiography. Technical improvements, including higher field strengths and improved pulse sequences, allow higher image resolution and contrast-to-noise ratio. These have facilitated development and validation of scoring methods of new pathologies: joint space narrowing and tenosynovitis. These have high reproducibility and moderate sensitivity to change, and can be added to RAMRIS. Combined scores of inflammation or joint damage may increase sensitivity to change and discriminative power. However, this requires further research. Updated 2016 RAMRIS recommendations and a research agenda were developed.

  13. 3-D cardiac MRI in free-breathing newborns and infants: when is respiratory gating necessary?

    Energy Technology Data Exchange (ETDEWEB)

    Seeger, Achim [University Hospital of Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); University Hospital of Tuebingen, Department of Diagnostic and Interventional Neuroradiology, Tuebingen (Germany); Krumm, Patrick; Schaefer, Juergen F.; Kramer, Ulrich [University Hospital of Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Hornung, Andreas; Sieverding, Ludger [University Hospital of Tuebingen, Department of Pediatric Cardiology, Tuebingen (Germany)

    2015-09-15

    Newborns and small infants have shallow breathing. To suggest criteria for when respiratory gating is necessary during cardiac MRI in newborns and infants. One-hundred ten data sets of newborns and infants with (n = 92, mean age: 1.9 ± 1.7 [SD] years) and without (n = 18, mean age: 1.6 ± 1.8 [SD] years) navigator gating were analysed retrospectively. The respiratory motion of the right hemidiaphragm was recorded and correlated to age, weight, body surface area and qualitative image quality on a 4-point score. Quantitative image quality assessment was performed (sharpness of the delineation of the ventricular septal wall) as well as a matched-pair comparison between navigator-gated and non-gated data sets. No significant differences were found in overall image quality or in the sharpness of the ventricular septal wall between gated and non-gated scans. A navigator acceptance of >80% was frequently found in patients ages <12 months, body surface area <0.40 m{sup 2}, body weight <10 kg and a size of <80 cm. Sequences without respiratory gating may be used in newborns and small infants, in particular if age <12 months, body surface area <0.40 m{sup 2}, body weight <10 kg and height <80 cm. (orig.)

  14. MRI-Based Nonrigid Motion Correction in Simultaneous PET/MRI

    Science.gov (United States)

    Chun, Se Young; Reese, Timothy G.; Ouyang, Jinsong; Guerin, Bastien; Catana, Ciprian; Zhu, Xuping; Alpert, Nathaniel M.; El Fakhri, Georges

    2014-01-01

    Respiratory and cardiac motion is the most serious limitation to whole-body PET, resulting in spatial resolution close to 1 cm. Furthermore, motion-induced inconsistencies in the attenuation measurements often lead to significant artifacts in the reconstructed images. Gating can remove motion artifacts at the cost of increased noise. This paper presents an approach to respiratory motion correction using simultaneous PET/MRI to demonstrate initial results in phantoms, rabbits, and nonhuman primates and discusses the prospects for clinical application. Methods Studies with a deformable phantom, a free-breathing primate, and rabbits implanted with radioactive beads were performed with simultaneous PET/MRI. Motion fields were estimated from concurrently acquired tagged MR images using 2 B-spline nonrigid image registration methods and incorporated into a PET list-mode ordered-subsets expectation maximization algorithm. Using the measured motion fields to transform both the emission data and the attenuation data, we could use all the coincidence data to reconstruct any phase of the respiratory cycle. We compared the resulting SNR and the channelized Hotelling observer (CHO) detection signal-to-noise ratio (SNR) in the motion-corrected reconstruction with the results obtained from standard gating and uncorrected studies. Results Motion correction virtually eliminated motion blur without reducing SNR, yielding images with SNR comparable to those obtained by gating with 5–8 times longer acquisitions in all studies. The CHO study in dynamic phantoms demonstrated a significant improvement (166%–276%) in lesion detection SNR with MRI-based motion correction as compared with gating (P < 0.001). This improvement was 43%–92% for large motion compared with lesion detection without motion correction (P < 0.001). CHO SNR in the rabbit studies confirmed these results. Conclusion Tagged MRI motion correction in simultaneous PET/MRI significantly improves lesion detection

  15. Magnetic Resonance Imaging (MRI) Safety

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) Safety What is MRI and how ... What is MRI and how does it work? Magnetic resonance imaging, or MRI, is a way of obtaining ...

  16. Semi-automated scar detection in delayed enhanced cardiac magnetic resonance images

    Science.gov (United States)

    Morisi, Rita; Donini, Bruno; Lanconelli, Nico; Rosengarden, James; Morgan, John; Harden, Stephen; Curzen, Nick

    2015-06-01

    Late enhancement cardiac magnetic resonance images (MRI) has the ability to precisely delineate myocardial scars. We present a semi-automated method for detecting scars in cardiac MRI. This model has the potential to improve routine clinical practice since quantification is not currently offered due to time constraints. A first segmentation step was developed for extracting the target regions for potential scar and determining pre-candidate objects. Pattern recognition methods are then applied to the segmented images in order to detect the position of the myocardial scar. The database of late gadolinium enhancement (LE) cardiac MR images consists of 111 blocks of images acquired from 63 patients at the University Hospital Southampton NHS Foundation Trust (UK). At least one scar was present for each patient, and all the scars were manually annotated by an expert. A group of images (around one third of the entire set) was used for training the system which was subsequently tested on all the remaining images. Four different classifiers were trained (Support Vector Machine (SVM), k-nearest neighbor (KNN), Bayesian and feed-forward neural network) and their performance was evaluated by using Free response Receiver Operating Characteristic (FROC) analysis. Feature selection was implemented for analyzing the importance of the various features. The segmentation method proposed allowed the region affected by the scar to be extracted correctly in 96% of the blocks of images. The SVM was shown to be the best classifier for our task, and our system reached an overall sensitivity of 80% with less than 7 false positives per patient. The method we present provides an effective tool for detection of scars on cardiac MRI. This may be of value in clinical practice by permitting routine reporting of scar quantification.

  17. Cardiac imaging. A multimodality approach

    Energy Technology Data Exchange (ETDEWEB)

    Thelen, Manfred [Johannes Gutenberg University Hospital, Mainz (Germany); Erbel, Raimund [University Hospital Essen (Germany). Dept. of Cardiology; Kreitner, Karl-Friedrich [Johannes Gutenberg University Hospital, Mainz (Germany). Clinic and Polyclinic for Diagnostic and Interventional Radiology; Barkhausen, Joerg (eds.) [University Hospital Schleswig-Holstein, Luebeck (Germany). Dept. of Radiology and Nuclear Medicine

    2009-07-01

    An excellent atlas on modern diagnostic imaging of the heart Written by an interdisciplinary team of experts, Cardiac Imaging: A Multimodality Approach features an in-depth introduction to all current imaging modalities for the diagnostic assessment of the heart as well as a clinical overview of cardiac diseases and main indications for cardiac imaging. With a particular emphasis on CT and MRI, the first part of the atlas also covers conventional radiography, echocardiography, angiography and nuclear medicine imaging. Leading specialists demonstrate the latest advances in the field, and compare the strengths and weaknesses of each modality. The book's second part features clinical chapters on heart defects, endocarditis, coronary heart disease, cardiomyopathies, myocarditis, cardiac tumors, pericardial diseases, pulmonary vascular diseases, and diseases of the thoracic aorta. The authors address anatomy, pathophysiology, and clinical features, and evaluate the various diagnostic options. Key features: - Highly regarded experts in cardiology and radiology off er image-based teaching of the latest techniques - Readers learn how to decide which modality to use for which indication - Visually highlighted tables and essential points allow for easy navigation through the text - More than 600 outstanding images show up-to-date technology and current imaging protocols Cardiac Imaging: A Multimodality Approach is a must-have desk reference for cardiologists and radiologists in practice, as well as a study guide for residents in both fields. It will also appeal to cardiac surgeons, general practitioners, and medical physicists with a special interest in imaging of the heart. (orig.)

  18. XD-GRASP: Golden-angle radial MRI with reconstruction of extra motion-state dimensions using compressed sensing.

    Science.gov (United States)

    Feng, Li; Axel, Leon; Chandarana, Hersh; Block, Kai Tobias; Sodickson, Daniel K; Otazo, Ricardo

    2016-02-01

    To develop a novel framework for free-breathing MRI called XD-GRASP, which sorts dynamic data into extra motion-state dimensions using the self-navigation properties of radial imaging and reconstructs the multidimensional dataset using compressed sensing. Radial k-space data are continuously acquired using the golden-angle sampling scheme and sorted into multiple motion-states based on respiratory and/or cardiac motion signals derived directly from the data. The resulting undersampled multidimensional dataset is reconstructed using a compressed sensing approach that exploits sparsity along the new dynamic dimensions. The performance of XD-GRASP is demonstrated for free-breathing three-dimensional (3D) abdominal imaging, two-dimensional (2D) cardiac cine imaging and 3D dynamic contrast-enhanced (DCE) MRI of the liver, comparing against reconstructions without motion sorting in both healthy volunteers and patients. XD-GRASP separates respiratory motion from cardiac motion in cardiac imaging, and respiratory motion from contrast enhancement in liver DCE-MRI, which improves image quality and reduces motion-blurring artifacts. XD-GRASP represents a new use of sparsity for motion compensation and a novel way to handle motions in the context of a continuous acquisition paradigm. Instead of removing or correcting motion, extra motion-state dimensions are reconstructed, which improves image quality and also offers new physiological information of potential clinical value. © 2015 Wiley Periodicals, Inc.

  19. Cell therapy in myocardial infarction: emphasis on the role of MRI

    International Nuclear Information System (INIS)

    Ye, Yuxiang; Bogaert, Jan

    2008-01-01

    Despite tremendous progress in myocardial infarct (MI) treatment, mortality rates remain substantial. Permanent loss of cardiomyocytes after ischemic injury, results in irreversible loss of myocardial contractility, reduction in ventricular performance, and may initiate the development of dilated heart failure. The discovery that pluripotent progenitor cells bear the capacity to differentiate to mature cardiac cells raised the hope of cell-based regenerative medicine. Engraftment of stem cells in the damaged myocardium, repair and functional improvement appeared suddenly a nearby reality. Promising results in animal models, and preliminary studies reporting the feasibility and safety of adult stem cell therapy in MI patients led to the first double-blinded randomized, placebo-controlled trials. The initial great enthusiasm for this paradigm shift in MI treatment has been tempered by the mainly negative or modestly positive study findings. Before new, larger clinical trials can be initiated, a number of critical questions and issues need to be considered starting with a scrutinized analysis of currently available data to extending our knowledge of the mechanism of scarless myocardial regeneration. Cardiac cell therapy necessitates a multidisciplinary approach, whereby imaging, in particular MRI, and the input of the imaging specialist is crucial to the success of cardiac cell regenerative medicine. MRI is an appealing technique for cell trafficking depicting engraftment, differentiation and survival. Endomyocardial cell administration can be achieved safely with MR fluoroscopy and MRI is without any doubt the most accurate and reproducible technique to measure study end-points. (orig.)

  20. An update on technical and methodological aspects for cardiac PET applications

    International Nuclear Information System (INIS)

    PRESOTTO, Luca; BUSNARDO, Elena; GIANOLLI, Luigi; BETTINARDI, Valentino

    2016-01-01

    Positron emission tomography (PET) is indicated for a large number of cardiac diseases: perfusion and viability studies are commonly used to evaluate coronary artery disease; PET can also be used to assess sarcoidosis and endocarditis, as well as to investigate amyloidosis. Furthermore, a hot topic for research is plaque characterization. Most of these studies are technically very challenging. High count rates and short acquisition times characterize perfusion scans while very small targets have to be imaged in inflammation/infection and plaques examinations. Furthermore, cardiac PET suffers from respiratory and cardiac motion blur. Each type of studies has specific requirements from the technical and methodological point of view, thus PET systems with overall high performances are required. Furthermore, in the era of hybrid PET/computed tomography (CT) and PET/Magnetic Resonance Imaging (MRI) systems, the combination of complementary functional and anatomical information can be used to improve diagnosis and prognosis. Moreover, PET images can be qualitatively and quantitatively improved exploiting information from the other modality, using advanced algorithms. In this review we will report the latest technological and methodological innovations for PET cardiac applications, with particular reference to the state of the art of the hybrid PET/CT and PET/MRI. We will also report the most recent advancements in software, from reconstruction algorithms to image processing and analysis programs.

  1. Work factors associated with return to work in out-of-hospital cardiac arrest survivors.

    Science.gov (United States)

    Descatha, Alexis; Dumas, Florence; Bougouin, Wulfran; Cariou, Alain; Geri, Guillaume

    2018-07-01

    Although the survival rate after out-of-hospital cardiac arrest (OHCA) has increased over time, little is known about the return to work of OHCA survivors. We aim to evaluate prevalence and factors associated with return to work (RTW) in OHCA survivors. All consecutive OHCA survivors aged 18-65 years and discharged alive from a Paris tertiary intensive care unit between 2000 and 2013 were included. Pre-hospital care, in-hospital care, and after-hospital discharge data, such as work description (work location, job classification, nature of the job) were compared relative to work status and RTW. Factors associated with RTW were evaluated using multivariable logistic regression. 153 OHCA survivors were included in the analysis. Among them, 96 (62.8%) returned to work an average of 714 days after OHCA (SD 1031); mostly to the same job (n = 72, 75%). Six patients changed jobs (4%) and 12 reduced their activity (10.6%). Factors associated with RTW were younger age (adjusted odds ratio (aOR) 3.64 [1.10; 12.02]), being managers and professionals, and service and sales workers (compared to technicians and associate professionals, clerical support workers, respectively aOR 3.43 [1.05; 11.22] and 4.69 [1.14; 19.37]), and workplace occurrence (aOR 11.72 [1.37; 99.93]). Two thirds of OHCA survivors, in the present study, returned to work. Patients with a higher-level job, and with the arrest occurring in the workplace, were more likely to return to work. Further research should include more details of job contents, evolution, financial consequences, as well as prevention practices related to work location. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Working in the magnetic field of ultrahigh field MRI

    International Nuclear Information System (INIS)

    Leitgeb, N.; Gombotz, H.

    2013-01-01

    Development of magnetic resonance imaging (MRI) device technology continues to increase the static magnetic flux densities applied and consequently leads to considerably increased occupational exposure. This has already made it necessary to review limits of occupational exposure and to postpone European legal regulations for occupational exposure to electromagnetic fields. This raises the question whether and if so which adverse health effects and health risks might be associated with occupational exposure to MRI ultra-high static magnetic fields. Based on a survey on interaction mechanisms recommendations and safety rules are presented to help minimize adverse health effects of emerging ultra-high field MRI. (orig.) [de

  3. SU-E-J-192: Verification of 4D-MRI Internal Target Volume Using Cine MRI

    Energy Technology Data Exchange (ETDEWEB)

    Lafata, K; Czito, B; Palta, M; Bashir, M; Yin, F; Cai, J [Duke University Medical Center, Durham, NC (United States)

    2014-06-01

    Purpose: To investigate the accuracy of 4D-MRI in determining the Internal Target Volume (ITV) used in radiation oncology treatment planning of liver cancers. Cine MRI is used as the standard baseline in establishing the feasibility and accuracy of 4D-MRI tumor motion within the liver. Methods: IRB approval was obtained for this retrospective study. Analysis was performed on MR images from four patients receiving external beam radiation therapy for liver cancer at our institution. Eligible patients received both Cine and 4D-MRI scans before treatment. Cine images were acquired sagittally in real time at a slice bisecting the tumor, while 4D images were acquired volumetrically. Cine MR DICOM headers were manipulated such that each respiratory frame was assigned a unique slice location. This approach permitted the treatment planning system (Eclipse, Varian Medical Systems) to recognize a complete respiratory cycle as a “volume”, where the gross tumor was contoured temporally. Software was developed to calculate the union of all frame contours in the structure set, resulting in the corresponding plane of the ITV projecting through the middle of the tumor, defined as the Internal Target Area (ITA). This was repeated for 4D-MRI, at the corresponding slice location, allowing a direct comparison of ITAs obtained from each modality. Results: Four patients have been analyzed. ITAs contoured from 4D-MRI correlate with contours from Cine MRI. The mean error of 4D values relative to Cine values is 7.67 +/− 2.55 %. No single ITA contoured from 4D-MRI demonstrated more than 10.5 % error compared to its Cine MRI counterpart. Conclusion: Motion management is a significant aspect of treatment planning within dynamic environments such as the liver, where diaphragmatic and cardiac activity influence plan accuracy. This small pilot study suggests that 4D-MRI based ITA measurements agree with Cine MRI based measurements, an important step towards clinical implementation. NIH 1R21

  4. SU-E-J-192: Verification of 4D-MRI Internal Target Volume Using Cine MRI

    International Nuclear Information System (INIS)

    Lafata, K; Czito, B; Palta, M; Bashir, M; Yin, F; Cai, J

    2014-01-01

    Purpose: To investigate the accuracy of 4D-MRI in determining the Internal Target Volume (ITV) used in radiation oncology treatment planning of liver cancers. Cine MRI is used as the standard baseline in establishing the feasibility and accuracy of 4D-MRI tumor motion within the liver. Methods: IRB approval was obtained for this retrospective study. Analysis was performed on MR images from four patients receiving external beam radiation therapy for liver cancer at our institution. Eligible patients received both Cine and 4D-MRI scans before treatment. Cine images were acquired sagittally in real time at a slice bisecting the tumor, while 4D images were acquired volumetrically. Cine MR DICOM headers were manipulated such that each respiratory frame was assigned a unique slice location. This approach permitted the treatment planning system (Eclipse, Varian Medical Systems) to recognize a complete respiratory cycle as a “volume”, where the gross tumor was contoured temporally. Software was developed to calculate the union of all frame contours in the structure set, resulting in the corresponding plane of the ITV projecting through the middle of the tumor, defined as the Internal Target Area (ITA). This was repeated for 4D-MRI, at the corresponding slice location, allowing a direct comparison of ITAs obtained from each modality. Results: Four patients have been analyzed. ITAs contoured from 4D-MRI correlate with contours from Cine MRI. The mean error of 4D values relative to Cine values is 7.67 +/− 2.55 %. No single ITA contoured from 4D-MRI demonstrated more than 10.5 % error compared to its Cine MRI counterpart. Conclusion: Motion management is a significant aspect of treatment planning within dynamic environments such as the liver, where diaphragmatic and cardiac activity influence plan accuracy. This small pilot study suggests that 4D-MRI based ITA measurements agree with Cine MRI based measurements, an important step towards clinical implementation. NIH 1R21

  5. MRI in patients with pacemakers? First global consensus recommendations from radiologists and cardiologists; Mit Schrittmacher ins MRT? Weltweit erste konsentierte Handlungsempfehlung von Radiologen und Kardiologen

    Energy Technology Data Exchange (ETDEWEB)

    Heindel, Walter; Kugel, Harald [University Hospital Muenster (Germany). Dept. of Clinical Radiology

    2017-03-15

    Under the title ''MR Imaging in Patients with Cardiac Pacemakers and Implantable Cardioverter Defibrillators'', this issue of Roefo - simultaneously with the journal of the German Cardiac Society ''Der Kardiologe'' - presents a consensus paper of the German Roentgen Society and the German Cardiac Society [1] [2] that was jointly written by the authors in radiology and cardiology but does not exclusively address cardiac MRI. This publication relates to MR imaging of all regions of the body. In Germany and internationally the number of MRI examinations is increasing: 1,008,944 examinations were performed on patients receiving inpatient treatment in 2005 while 1,767,005 examinations were performed in 2013 (DRG hospitals). This development can be attributed to our aging population as well as to new indications for MRI including: Analyses of tissue composition and function, for example in the liver [3] [4] and the heart [5] [6]; multiparametric analyses of MR perfusion, e.g. in treated brain tumors [7]; new organs such as the lung [8]; dedicated examinations for intervention planning and operation monitoring [9] [10] [11]; as well as MRI-guided interventions [12] [13] [14] [15] [16]. Implants must always be considered in all of these MRI examinations even if the reason for the examination request is not related to an implant. The involvement of cardiology in this case is not based on the medical issue but rather on the type of implant. Expertise in cardiology is required when dealing with cardiac pacemakers (PM) and implantable cardioverter defibrillators (ICD).

  6. Methods of estimation of mitral valve regurgitation for the cardiac surgeon

    Directory of Open Access Journals (Sweden)

    Baikoussis Nikolaos G

    2009-07-01

    Full Text Available Abstract Mitral valve regurgitation is a relatively common and important heart valve lesion in clinical practice and adequate assessment is fundamental to decision on management, repair or replacement. Disease localised to the posterior mitral valve leaflet or focal involvement of the anterior mitral valve leaflet is most amenable to mitral valve repair, whereas patients with extensive involvement of the anterior leaflet or incomplete closure of the valve are more suitable for valve replacement. Echocardiography is the recognized investigation of choice for heart valve disease evaluation and assessment. However, the technique is depended on operator experience and on patient's hemodynamic profile, and may not always give optimal diagnostic views of mitral valve dysfunction. Cardiac catheterization is related to common complications of an interventional procedure and needs a hemodynamic laboratory. Cardiac magnetic resonance (MRI seems to be a useful tool which gives details about mitral valve anatomy, precise point of valve damage, as well as the quantity of regurgitation. Finally, despite of its higher cost, cardiac MRI using cine images with optimized spatial and temporal resolution can also resolve mitral valve leaflet structural motion, and can reliably estimate the grade of regurgitation.

  7. MRI

    Science.gov (United States)

    ... the room. Pins, hairpins, metal zippers, and similar metallic items can distort the images. Removable dental work ... an MRI can cause heart pacemakers and other implants not to work as well. The magnets can ...

  8. Analysis of chronic aortic regurgitation by 2D and 3D echocardiography and cardiac MRI

    Science.gov (United States)

    Stoebe, Stephan; Metze, Michael; Jurisch, Daniel; Tayal, Bhupendar; Solty, Kilian; Laufs, Ulrich; Pfeiffer, Dietrich; Hagendorff, Andreas

    2018-01-01

    Purpose The study compares the feasibility of the quantitative volumetric and semi-quantitative approach for quantification of chronic aortic regurgitation (AR) using different imaging modalities. Methods Left ventricular (LV) volumes, regurgitant volumes (RVol) and regurgitant fractions (RF) were assessed retrospectively by 2D, 3D echocardiography and cMRI in 55 chronic AR patients. Semi-quantitative parameters were assessed by 2D echocardiography. Results 22 (40%) patients had mild, 25 (46%) moderate and 8 (14%) severe AR. The quantitative volumetric approach was feasible using 2D, 3D echocardiography and cMRI, whereas the feasibility of semi-quantitative parameters varied considerably. LV volume (LVEDV, LVESV, SVtot) analyses showed good correlations between the different imaging modalities, although significantly increased LV volumes were assessed by cMRI. RVol was significantly different between 2D/3D echocardiography and 2D echocardiography/cMRI but was not significantly different between 3D echocardiography/cMRI. RF was not statistically different between 2D echocardiography/cMRI and 3D echocardiography/cMRI showing poor correlations (r echocardiography and 2D echocardiography/cMRI and good agreement was observed between 3D echocardiography/cMRI. Conclusion Semi-quantitative parameters are difficult to determine by 2D echocardiography in clinical routine. The quantitative volumetric RF assessment seems to be feasible and can be discussed as an alternative approach in chronic AR. However, RVol and RF did not correlate well between the different imaging modalities. The best agreement for grading of AR severity by RF was observed between 3D echocardiography and cMRI. LV volumes can be verified by different approaches and different imaging modalities. PMID:29519957

  9. 2017 multimodality appropriate use criteria for noninvasive cardiac imaging: Export consensus of the Asian society of cardiovascular imaging

    Energy Technology Data Exchange (ETDEWEB)

    Beck, Kyong Min Sarah [Dept. of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Kim, Jeong A [Dept. of Radiology, Ilsan Paik Hospital, Inje University College of Medicine, Goyang (Korea, Republic of); Choe, Yeon Hyeon [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); and others

    2017-11-15

    In 2010, the Asian Society of Cardiovascular Imaging (ASCI) provided recommendations for cardiac CT and MRI, and this document reflects an update of the 2010 ASCI appropriate use criteria (AUC). In 2016, the ASCI formed a new working group for revision of AUC for noninvasive cardiac imaging. A major change that we made in this document is the rating of various noninvasive tests (exercise electrocardiogram, echocardiography, positron emission tomography, single-photon emission computed tomography, radionuclide imaging, cardiac magnetic resonance, and cardiac computed tomography/angiography), compared side by side for their applications in various clinical scenarios. Ninety-five clinical scenarios were developed from eight selected pre-existing guidelines and classified into four sections as follows: 1) detection of coronary artery disease, symptomatic or asymptomatic; 2) cardiac evaluation in various clinical scenarios; 3) use of imaging modality according to prior testing; and 4) evaluation of cardiac structure and function. The clinical scenarios were scored by a separate rating committee on a scale of 1–9 to designate appropriate use, uncertain use, or inappropriate use according to a modified Delphi method. Overall, the AUC ratings for CT were higher than those of previous guidelines. These new AUC provide guidance for clinicians choosing among available testing modalities for various cardiac diseases and are also unique, given that most previous AUC for noninvasive imaging include only one imaging technique. As cardiac imaging is multimodal in nature, we believe that these AUC will be more useful for clinical decision making.

  10. Cardiac function of the naked mole-rat: ecophysiological responses to working underground.

    Science.gov (United States)

    Grimes, Kelly M; Voorhees, Andrew; Chiao, Ying Ann; Han, Hai-Chao; Lindsey, Merry L; Buffenstein, Rochelle

    2014-03-01

    The naked mole-rat (NMR) is a strictly subterranean rodent with a low resting metabolic rate. Nevertheless, it can greatly increase its metabolic activity to meet the high energetic demands associated with digging through compacted soils in its xeric natural habitat where food is patchily distributed. We hypothesized that the NMR heart would naturally have low basal function and exhibit a large cardiac reserve, thereby mirroring the species' low basal metabolism and large metabolic scope. Echocardiography showed that young (2-4 yr old) healthy NMRs have low fractional shortening (28 ± 2%), ejection fraction (43 ± 2%), and cardiac output (6.5 ± 0.4 ml/min), indicating low basal cardiac function. Histology revealed large NMR cardiomyocyte cross-sectional area (216 ± 10 μm(2)) and cardiac collagen deposition of 2.2 ± 0.4%. Neither of these histomorphometric traits was considered pathological, since biaxial tensile testing showed no increase in passive ventricular stiffness. NMR cardiomyocyte fibers showed a low degree of rotation, contributing to the observed low NMR cardiac contractility. Interestingly, when the exercise mimetic dobutamine (3 μg/g ip) was administered, NMRs showed pronounced increases in fractional shortening, ejection fraction, cardiac output, and stroke volume, indicating an increased cardiac reserve. The relatively low basal cardiac function and enhanced cardiac reserve of NMRs are likely to be ecophysiological adaptations to life in an energetically taxing environment.

  11. Depiction of lower limb venous anatomy in patients undergoing interventional deep venous reconstruction-the role of balanced steady state free precession MRI.

    Science.gov (United States)

    Helyar, Vincent G; Gupta, Yuri; Blakeway, Lyndall; Charles-Edwards, Geoff; Katsanos, Konstantinos; Karunanithy, Narayan

    2018-02-01

    This study evaluates the use of balanced steady-state free precession MRI (bSSFP-MRI) in the diagnostic work-up of patients undergoing interventional deep venous reconstruction (I-DVR). Intravenous digital subtraction angiography (IVDSA) was used as the gold-standard for comparison to assess disease extent and severity. A retrospective comparison of bSSFP-MRI to IVDSA was performed in all patients undergoing both examinations for treatment planning prior to I-DVR. The severity of disease in each venous segment was graded by two board-certified radiologists working independently, according to a predetermined classification system. In total, 44 patients (225 venous segments) fulfilled the inclusion criteria. A total of 156 abnormal venous segments were diagnosed using bSSFP-MRI compared with 151 using IVDSA. The prevalence of disease was higher in the iliac and femoral segments (range, 79.6-88.6%). Overall sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and the diagnostic ratio for bSSFP-MRI were 99.3%, 91.9%, 12.3, 0.007 and 1700, respectively. This study supports the use of non-contrast balanced SSFP-MRI in the assessment of the deep veins of the lower limb prior to I-DVR. The technique offers an accurate, fast and non-invasive alternative to IVDSA. Advances in Knowledge: Although balanced SSFP-MRI is commonly used in cardiac imaging, its use elsewhere is limited and its use in evaluating the deep veins prior to interventional reconstruction is not described. Our study demonstrates the usefulness of this technique in the work-up of patients awaiting interventional venous reconstruction compared with the current gold standard.

  12. Role of cardiac MRI in nonischemic cardiomyopathies.

    Science.gov (United States)

    Anand, Senthil; Janardhanan, Rajesh

    2016-01-01

    Cardiac magnetic resonance (CMR) with its higher spatial resolution is considered the gold standard for evaluating ventricular mass, volumes, and ejection fraction. CMR can be used for accurate diagnosis of several conditions, especially cardiomyopathies. The purpose of this article is to review the utility of CMR in the diagnosis and management of nonischemic cardiomyopathies. We have reviewed both common and rare types of nonischemic cardiomyopathies in detail and elaborated on the specific CMR findings in each. We believe that CMR is an invaluable tool, not only in differentiating nonischemic from ischemic cardiomyopathy, but also in aiding the accurate diagnosis and management of the subtype of nonischemic cardiomyopathy. CMR should routinely be integrated in the diagnostic workup of various cardiomyopathies. Published by Elsevier B.V.

  13. Role of cardiac MRI in nonischemic cardiomyopathies

    Directory of Open Access Journals (Sweden)

    Senthil Anand

    2016-05-01

    Full Text Available Cardiac magnetic resonance (CMR with its higher spatial resolution is considered the gold standard for evaluating ventricular mass, volumes, and ejection fraction. CMR can be used for accurate diagnosis of several conditions, especially cardiomyopathies. The purpose of this article is to review the utility of CMR in the diagnosis and management of nonischemic cardiomyopathies. We have reviewed both common and rare types of nonischemic cardiomyopathies in detail and elaborated on the specific CMR findings in each. We believe that CMR is an invaluable tool, not only in differentiating nonischemic from ischemic cardiomyopathy, but also in aiding the accurate diagnosis and management of the subtype of nonischemic cardiomyopathy. CMR should routinely be integrated in the diagnostic workup of various cardiomyopathies.

  14. fMRI characterization of visual working memory recognition.

    Science.gov (United States)

    Rahm, Benjamin; Kaiser, Jochen; Unterrainer, Josef M; Simon, Juliane; Bledowski, Christoph

    2014-04-15

    Encoding and maintenance of information in visual working memory have been extensively studied, highlighting the crucial and capacity-limiting role of fronto-parietal regions. In contrast, the neural basis of recognition in visual working memory has remained largely unspecified. Cognitive models suggest that recognition relies on a matching process that compares sensory information with the mental representations held in memory. To characterize the neural basis of recognition we varied both the need for recognition and the degree of similarity between the probe item and the memory contents, while independently manipulating memory load to produce load-related fronto-parietal activations. fMRI revealed a fractionation of working memory functions across four distributed networks. First, fronto-parietal regions were activated independent of the need for recognition. Second, anterior parts of load-related parietal regions contributed to recognition but their activations were independent of the difficulty of matching in terms of sample-probe similarity. These results argue against a key role of the fronto-parietal attention network in recognition. Rather the third group of regions including bilateral temporo-parietal junction, posterior cingulate cortex and superior frontal sulcus reflected demands on matching both in terms of sample-probe-similarity and the number of items to be compared. Also, fourth, bilateral motor regions and right superior parietal cortex showed higher activation when matching provided clear evidence for a decision. Together, the segregation between the well-known fronto-parietal activations attributed to attentional operations in working memory from those regions involved in matching supports the theoretical view of separable attentional and mnemonic contributions to working memory. Yet, the close theoretical and empirical correspondence to perceptual decision making may call for an explicit consideration of decision making mechanisms in

  15. Clinical impact of 18F-FDG-PET/CT in the extra cardiac work-up of patients with infective endocarditis

    DEFF Research Database (Denmark)

    Asmar, Ali; Ozcan, Cengiz; Diederichsen, Axel C P

    2014-01-01

    OBJECTIVE: The purpose of this study was to assess the clinical importance of (18)F-FDG-PET/CT used in the extra cardiac work-up of patients with infective endocarditis (IE). BACKGROUND: IE is a serious condition with a significant mortality. Besides the degree of valvular involvement, the progno......OBJECTIVE: The purpose of this study was to assess the clinical importance of (18)F-FDG-PET/CT used in the extra cardiac work-up of patients with infective endocarditis (IE). BACKGROUND: IE is a serious condition with a significant mortality. Besides the degree of valvular involvement...

  16. Multimodal Registration of gated cardiac PET, CT and MR sequences

    International Nuclear Information System (INIS)

    Baty, X.

    2007-07-01

    The research described in this manuscript deals with the multimodal registration of cardiac images from Magnetic Resonance Imaging (MRI), Position Emission Tomography (PET) and Computerized Tomography (CT). All these modalities are gated to the Electrocardiogram (ECG) and provide information to evaluate cardiac function, and to diagnose and to follow-up cardiovascular pathologies. PET imaging allows the evaluation of ventricular function and MRI is a gold standard for the study of the left ventricular function. The goal of our registration process is to merge functional (from PET) and anatomical images (from CT and MRI). Our process is adapted to the modalities used and is divided in two steps: (i) a global rigid 3-dimensional model-based ICP (Iterative Closest Point) registration between CT and MR data and (ii) an iconic 2-dimensional registration based on Free Form Deformations and Mutual Information. This last step presents an original contribution by using a composite image of CT (which presents epicardic contours) and PET (where endocardic contours are partially visible) data to make mutual information more accurate in representing the similarity with the MR data. To speed up the whole process, we also present a transformation initialization scheme using displacement field obtained form MR data only. The obtained results have been evaluated by experts. (author)

  17. Self-gating MR imaging of the fetal heart: comparison with real cardiac triggering

    International Nuclear Information System (INIS)

    Yamamura, Jin; Frisch, Michael; Ecker, Hannes; Adam, Gerhard; Wedegaertner, Ulrike; Graessner, Joachim; Hecher, Kurt

    2011-01-01

    To investigate the self-gating technique for MR imaging of the fetal heart in a sheep model. MR images of 6 fetal sheep heart were obtained at 1.5T. For self-gating MRI of the fetal heart a cine SSFP in short axis, two and four chamber view was used. Self-gated images were compared with real cardiac triggered MR images (pulse-wave triggering). MRI of the fetal heart was performed using both techniques simultaneously. Image quality was assessed and the left ventricular volume and function were measured and compared. Compared with pulse-wave triggering, the self-gating technique produced slightly inferior images with artifacts. Especially the atrial septum could not be so clearly depicted. The contraction of the fetal heart was shown in cine sequences in both techniques. The average blood volumes could be measured with both techniques with no significant difference: at end-systole 3.1 ml (SD± 0.2), at end-diastole 4.9 ml (±0.2), with ejection fractions at 38.6%, respectively 39%. Both self-gating and pulse-wave triggered cardiac MRI of the fetal heart allowed the evaluation of anatomical structures and functional information. Images obtained by self-gating technique were slightly inferior than the pulse-wave triggered MRI. (orig.)

  18. Small animal simultaneous PET/MRI: initial experiences in a 9.4 T microMRI

    Energy Technology Data Exchange (ETDEWEB)

    Maramraju, Sri Harsha; Ravindranath, Bosky; Vaska, Paul; Schlyer, David J [Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY (United States); Smith, S David; Schulz, Daniela [Medical Department, Brookhaven National Laboratory, Upton, NY (United States); Junnarkar, Sachin S; Rescia, Sergio [Instrumentation Division, Brookhaven National Laboratory, Upton, NY (United States); Stoll, Sean; Purschke, Martin L; Woody, Craig L [Physics Department, Brookhaven National Laboratory, Upton, NY (United States); Southekal, Sudeepti [Brigham and Women' s Hospital, Boston, MA (United States); Pratte, Jean-Francois, E-mail: schlyer@bnl.gov [Universite de Sherbrooke, Sherbrooke, Quebec (Canada)

    2011-04-21

    We developed a non-magnetic positron-emission tomography (PET) device based on the rat conscious animal PET that operates in a small-animal magnetic resonance imaging (MRI) scanner, thereby enabling us to carry out simultaneous PET/MRI studies. The PET detector comprises 12 detector blocks, each being a 4 x 8 array of lutetium oxyorthosilicate crystals (2.22 x 2.22 x 5 mm{sup 3}) coupled to a matching non-magnetic avalanche photodiode array. The detector blocks, housed in a plastic case, form a 38 mm inner diameter ring with an 18 mm axial extent. Custom-built MRI coils fit inside the positron-emission tomography (PET) device, operating in transceiver mode. The PET insert is integrated with a Bruker 9.4 T 210 mm clear-bore diameter MRI scanner. We acquired simultaneous PET/MR images of phantoms, of in vivo rat brain, and of cardiac-gated mouse heart using [{sup 11}C]raclopride and 2-deoxy-2-[{sup 18}F]fluoro-d-glucose PET radiotracers. There was minor interference between the PET electronics and the MRI during simultaneous operation, and small effects on the signal-to-noise ratio in the MR images in the presence of the PET, but no noticeable visual artifacts. Gradient echo and high-duty-cycle spin echo radio frequency (RF) pulses resulted in a 7% and a 28% loss in PET counts, respectively, due to high PET counts during the RF pulses that had to be gated out. The calibration of the activity concentration of PET data during MR pulsing is reproducible within less than 6%. Our initial results demonstrate the feasibility of performing simultaneous PET and MRI studies in adult rats and mice using the same PET insert in a small-bore 9.4 T MRI.

  19. Cardiac atrophy after bed rest and spaceflight

    Science.gov (United States)

    Perhonen, M. A.; Franco, F.; Lane, L. D.; Buckey, J. C.; Blomqvist, C. G.; Zerwekh, J. E.; Peshock, R. M.; Weatherall, P. T.; Levine, B. D.

    2001-01-01

    Cardiac muscle adapts well to changes in loading conditions. For example, left ventricular (LV) hypertrophy may be induced physiologically (via exercise training) or pathologically (via hypertension or valvular heart disease). If hypertension is treated, LV hypertrophy regresses, suggesting a sensitivity to LV work. However, whether physical inactivity in nonathletic populations causes adaptive changes in LV mass or even frank atrophy is not clear. We exposed previously sedentary men to 6 (n = 5) and 12 (n = 3) wk of horizontal bed rest. LV and right ventricular (RV) mass and end-diastolic volume were measured using cine magnetic resonance imaging (MRI) at 2, 6, and 12 wk of bed rest; five healthy men were also studied before and after at least 6 wk of routine daily activities as controls. In addition, four astronauts were exposed to the complete elimination of hydrostatic gradients during a spaceflight of 10 days. During bed rest, LV mass decreased by 8.0 +/- 2.2% (P = 0.005) after 6 wk with an additional atrophy of 7.6 +/- 2.3% in the subjects who remained in bed for 12 wk; there was no change in LV mass for the control subjects (153.0 +/- 12.2 vs. 153.4 +/- 12.1 g, P = 0.81). Mean wall thickness decreased (4 +/- 2.5%, P = 0.01) after 6 wk of bed rest associated with the decrease in LV mass, suggesting a physiological remodeling with respect to altered load. LV end-diastolic volume decreased by 14 +/- 1.7% (P = 0.002) after 2 wk of bed rest and changed minimally thereafter. After 6 wk of bed rest, RV free wall mass decreased by 10 +/- 2.7% (P = 0.06) and RV end-diastolic volume by 16 +/- 7.9% (P = 0.06). After spaceflight, LV mass decreased by 12 +/- 6.9% (P = 0.07). In conclusion, cardiac atrophy occurs during prolonged (6 wk) horizontal bed rest and may also occur after short-term spaceflight. We suggest that cardiac atrophy is due to a physiological adaptation to reduced myocardial load and work in real or simulated microgravity and demonstrates the plasticity

  20. MRI of 'brain death'

    Energy Technology Data Exchange (ETDEWEB)

    Nishino, Shigeki; Itoh, Takahiko; Tuchida, Shohei; Kinugasa, Kazushi; Asari, Shoji; Nishimoto, Akira (Okayama Univ. (Japan). School of Medicine); Sanou, Kazuo

    1990-12-01

    Magnetic resonance imaging (MRI) was undertaken for two patients who suffered from severe cerebrovascular diseases and were clinically brain dead. The MRI system we used was Resona (Yokogawa Medical Systems, superconductive system 0.5 T) and the CT apparatus was Toshiba TCT-300. Initial CT and MRI were undertaken as soon as possible after admission, and repeated sequentially. After diagnosis of brain death, we performed angiography to determine cerebral circulatory arrest, and MRI obtained at the same time was compared with the angiogram and CT. Case 1 was a 77-year-old man who was admitted in an unconscious state. CT and MRI on the second day after hospitalization revealed cerebellar infarction. He was diagnosed as brain dead on day 4. Case 2 was a 35-year-old man. When he was transferred to our hospital, he was in cardiorespiratory arrested. Cardiac resuscitation was successful but no spontaneous respiration appeared. CT and MRI on admission revealed right intracerebral hemorrhage. Angiography revealed cessation of contrast medium in intracranial vessels in both of the patients. We found no 'flow signal void sign' in the bilateral internal carotid and basilar arteries on MRI images in both cases after brain death. MRI, showing us the anatomical changes of the brain, clearly revealed brain herniations, even though only nuclear findings of 'brain tamponade' were seen on CT. But in Case 1, we could not see the infarct lesions in the cerebellum on MR images obtained after brain death. This phenomenon was caused by the whole brain ischemia masking the initial ischemic lesions. We concluded that MRI was useful not only the anatomical display of lesions and brain herniation with high contrast resolution but for obtaining information on cerebral circulation of brain death. (author).

  1. Synthetic generation of myocardial blood-oxygen-level-dependent MRI time series via structural sparse decomposition modeling.

    Science.gov (United States)

    Rusu, Cristian; Morisi, Rita; Boschetto, Davide; Dharmakumar, Rohan; Tsaftaris, Sotirios A

    2014-07-01

    This paper aims to identify approaches that generate appropriate synthetic data (computer generated) for cardiac phase-resolved blood-oxygen-level-dependent (CP-BOLD) MRI. CP-BOLD MRI is a new contrast agent- and stress-free approach for examining changes in myocardial oxygenation in response to coronary artery disease. However, since signal intensity changes are subtle, rapid visualization is not possible with the naked eye. Quantifying and visualizing the extent of disease relies on myocardial segmentation and registration to isolate the myocardium and establish temporal correspondences and ischemia detection algorithms to identify temporal differences in BOLD signal intensity patterns. If transmurality of the defect is of interest pixel-level analysis is necessary and thus a higher precision in registration is required. Such precision is currently not available affecting the design and performance of the ischemia detection algorithms. In this work, to enable algorithmic developments of ischemia detection irrespective to registration accuracy, we propose an approach that generates synthetic pixel-level myocardial time series. We do this by 1) modeling the temporal changes in BOLD signal intensity based on sparse multi-component dictionary learning, whereby segmentally derived myocardial time series are extracted from canine experimental data to learn the model; and 2) demonstrating the resemblance between real and synthetic time series for validation purposes. We envision that the proposed approach has the capacity to accelerate development of tools for ischemia detection while markedly reducing experimental costs so that cardiac BOLD MRI can be rapidly translated into the clinical arena for the noninvasive assessment of ischemic heart disease.

  2. [Sense of Coherence Scale according to Antonovsky as a possible predictor for return to work for cardiac surgery intensive care patients].

    Science.gov (United States)

    Benstoem, C; Wübker, R; Lüngen, M; Breuer, T; Marx, G; Autschbach, R; Goetzenich, A; Schnoering, H

    2018-05-14

    For cardiac surgery patients who were employed prior to surgery, the return to their professional life is of special importance. In addition to medical reasons, such as pre-existing conditions, the success of the operation or postoperative course and patient-intrinsic reasons, which can be assessed with the Sense of Coherence (SOC) scale by Antonovsky, may also play a role in the question of a possible return into working life. In this study 278 patients (invasive coronary artery bypass graft surgery and/or surgery on heart valves, age work. The cohort was stratified according to the time of return to work. Subsequently, the point of maximum sensitivity and specificity was determined for the total SOC score and the prediction power was considered. Of the 278 patients, 61 questionnaires (22%) were considered as eligible and included in the analysis. Of these, 47 participants had returned to work after undergoing cardiac surgery and 14 participants had not. We observed significant differences in SOC values between both groups (146.07 ± 29.76 versus 124.29 ± 28.8, p = 0.020). Patients that returned to work within the first 6 months after surgery showed even higher SOC scores (148.56 ± 28.98, p = 0.034). Patients with an SOC score life after cardiac surgery. The SOC is an easily obtainable score that reliably predicts the probability of return to work after cardiac surgery.

  3. Analysis of long- and short-range contribution to adhesion work in cardiac fibroblasts: An atomic force microscopy study

    Energy Technology Data Exchange (ETDEWEB)

    Sbaizero, O., E-mail: sbaizero@units.it [Department of Engineering and Architecture, University of Trieste (Italy); University of Colorado Cardiovascular Institute, University of Colorado Denver, Aurora (United States); DelFavero, G. [Department of Engineering and Architecture, University of Trieste (Italy); Martinelli, V. [International Center for Genetic Engineering and Biotechnology, Trieste (Italy); Long, C.S.; Mestroni, L. [University of Colorado Cardiovascular Institute, University of Colorado Denver, Aurora (United States)

    2015-04-01

    Atomic force microscopy (AFM) for single-cell force spectroscopy (SCFS) and Poisson statistic were used to analyze the detachment work recorded during the removal of gold-covered microspheres from cardiac fibroblasts. The effect of Cytochalasin D, a disruptor of the actin cytoskeleton, on cell adhesion was also tested. The adhesion work was assessed using a Poisson analysis also derived from single-cell force spectroscopy retracting curves. The use of Poisson analysis to get adhesion work from AFM curves is quite a novel method, and in this case, proved to be effective to study the short-range and long-range contributions to the adhesion work. This method avoids the difficult identification of minor peaks in the AFM retracting curves by creating what can be considered an average adhesion work. Even though the effect of actin depolymerisation is well documented, its use revealed that control cardiac fibroblasts (CT) exhibit a work of adhesion at least 5 times higher than that of the Cytochalasin treated cells. However, our results indicate that in both cells short-range and long-range contributions to the adhesion work are nearly equal and the same heterogeneity index describes both cells. Therefore, we infer that the different adhesion behaviors might be explained by the presence of fewer membrane adhesion molecules available at the AFM tip–cell interface under circumstances where the actin cytoskeleton has been disrupted. - Highlights: • AFM force–deformation curve was used to characterize the cardiac fibroblast adhesion behavior. • The amount and nature of adhesion were assessed using a Poisson analysis applied to the AFM curve. • The work of adhesion for control cells was about four times higher than that of the Cyt-D treated cells. • Short- and long-range contributions to adhesion are nearly equal for both control and treated cells.

  4. High resolution MR imaging of the fetal heart with cardiac triggering: a feasibility study in the sheep fetus

    Energy Technology Data Exchange (ETDEWEB)

    Yamamura, Jin; Frisch, Michael; Adam, Gerhard; Wedegaertner, Ulrike [University Hospital Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Schnackenburg, Bernhard; Kooijmann, Hendrik [Philips Medical Systems, Hamburg (Germany); Hecher, Kurt [University Hospital Hamburg-Eppendorf, Department of Obstetrics and Fetal Medicine, Hamburg (Germany)

    2009-10-15

    The aim of this study was to perform fetal cardiac magnetic resonance imaging (MRI) with triggering of the fetal heart beat in utero in a sheep model. All experimental protocols were reviewed and the usage of ewes and fetuses was approved by the local animal protection authorities. Images of the hearts of six pregnant ewes were obtained by using a 1.5-T MR system (Philips Medical Systems, Best, Netherlands). The fetuses were chronically instrumented with a carotid catheter to measure the fetal heart frequency for the cardiac triggering. Pulse wave triggered, breath-hold cine-MRI with steady-state free precession (SSFP) was achieved in short axis, two-, four- and three-chamber views. The left ventricular volume and thus the function were measured from the short axis. The fetal heart frequencies ranged between 130 and 160 bpm. The mitral, tricuspid, aortic, and pulmonary valves could be clearly observed. The foramen ovale could be visualized. Myocardial contraction was shown in cine sequences. The average blood volume at the end systole was 3.4{+-}0.2 ml ({+-} SD). The average volume at end diastole was 5.2{+-}0.2 ml; thus the stroke volumes of the left ventricle in the systole were between 1.7 and 1.9 ml with ejection fractions of 38.6% and 39%, respectively. The pulse wave triggered cardiac MRI of the fetal heart allowed evaluation of anatomical structures and functional information. This feasibility study demonstrates the applicability of MRI for future evaluation of fetuses with complex congenital heart defects, once a noninvasive method has been developed to perform fetal cardiac triggering. (orig.)

  5. Myocardial perfusion MRI with sliding-window conjugate-gradient HYPR.

    Science.gov (United States)

    Ge, Lan; Kino, Aya; Griswold, Mark; Mistretta, Charles; Carr, James C; Li, Debiao

    2009-10-01

    First-pass perfusion MRI is a promising technique for detecting ischemic heart disease. However, the diagnostic value of the method is limited by the low spatial coverage, resolution, signal-to-noise ratio (SNR), and cardiac motion-related image artifacts. In this study we investigated the feasibility of using a method that combines sliding window and CG-HYPR methods (SW-CG-HYPR) to reduce the acquisition window for each slice while maintaining the temporal resolution of one frame per heartbeat in myocardial perfusion MRI. This method allows an increased number of slices, reduced motion artifacts, and preserves the relatively high SNR and spatial resolution of the "composite images." Results from eight volunteers demonstrate the feasibility of SW-CG-HYPR for accelerated myocardial perfusion imaging with accurate signal intensity changes of left ventricle blood pool and myocardium. Using this method the acquisition time per cardiac cycle was reduced by a factor of 4 and the number of slices was increased from 3 to 8 as compared to the conventional technique. The SNR of the myocardium at peak enhancement with SW-CG-HYPR (13.83 +/- 2.60) was significantly higher (P < 0.05) than the conventional turbo-FLASH protocol (8.40 +/- 1.62). Also, the spatial resolution of the myocardial perfection images was significantly improved. SW-CG-HYPR is a promising technique for myocardial perfusion MRI. (c) 2009 Wiley-Liss, Inc.

  6. Novel Mutation in the TSC2 Gene Associated with Prenatally Diagnosed Cardiac Rhabdomyomas and Cerebral Tuberous Sclerosis

    Directory of Open Access Journals (Sweden)

    Chih-Ping Chen

    2006-01-01

    Full Text Available Cardiac rhabdomyomas are prenatal echocardiographic markers for tuberous sclerosis complex (TSC. TSC is caused by mutations in the genes TSC1 and TSC2. We report a 28-year-old, gravida 5, para 2, woman with an uncomplicated pregnancy until prenatal ultrasound at 34 weeks' gestation revealed fetal cardiac tumors. Ultrafast magnetic resonance imaging (MRI at 36 weeks' gestation showed cardiac rhab-domyomas and small subependymal tubers. At 39 weeks' gestation, a 2262 g female infant was delivered uneventfully. Postnatal echocardiography confirmed cardiac rhabdomyomas and MRI verified small cerebral subependymal tubers. Mutational analysis of TSC1 and TSC2 genes using denaturing high-performance liquid chromatography and direct sequencing of the genes was performed and revealed that the parents had wildtype DNA, while the proband was heterozygous for a novel de novo nonsense mutation, c.4830 G > A, in exon 36 of the TSC2 gene, resulting in a change of codon 1610 TGG (tryptophan to TGA (stop codon. The mutation predicted a W1610X premature termination of the tuberin protein. These findings support an association between a TSC2 de novo nonsense mutation and prenatally detected cardiac rhabdomyomas and cerebral tuberous sclerosis. Familial molecular analysis of TSC1 and TSC2 in cases with prenatally diagnosed cardiac rhabdomyomas and cerebral tuberous sclerosis lesions is helpful in prenatal diagnosis and genetic counseling.

  7. A protocol for patients with cardiovascular implantable devices undergoing magnetic resonance imaging (MRI): should defibrillation threshold testing be performed post-(MRI).

    Science.gov (United States)

    Burke, Peter Thomas; Ghanbari, Hamid; Alexander, Patrick B; Shaw, Michael K; Daccarett, Marcos; Machado, Christian

    2010-06-01

    Magnetic resonance imaging (MRI) in patients with Cardiovascular Implantable Electronic Devices (CIED) has not been approved by the Food and Drug Administration. Recent data suggests MRI as a relative rather than absolute contraindication in CIED patients. Recently, the American Heart Association has recommended defibrillation threshold testing (DFTT) in implantable cardioverter defibrillator (ICD) patients undergoing MRI. We evaluated the feasibility and safety of a protocol for MRI in CIED patients, incorporating the new recommendations on DFTT. Consecutive patients with CIED undergoing MRI were included. The protocol consisted of continuous monitoring during imaging, device interrogation pre- and post-MRI, reprogramming of the pacemaker to an asynchronous mode in pacemaker-dependent (PMD) patients and a non-tracking/sensing mode for non-PMD patients. All tachyarrhythmia therapies were disabled. Devices were interrogated for lead impedance, battery life, pacing, and sensing thresholds. All patients with ICD underwent DFTT/defibrillator safety margin testing (DSMT) post-MRI. A total of 92 MRI's at 1.5 Tesla were performed in 38 patients. A total of 13 PMD patients, ten ICD patients, four cardiac resynchronization therapy with defibrillator (CRT-D) patients, and 11 non-PMD patients were scanned from four major manufacturers. No device circuitry damage, programming alterations, inappropriate shocks, failure to pace, or changes in sensing, pacing, or defibrillator thresholds were found on single or multiple MRI sessions. Our protocol for MRI in CIED patients appears safe, feasible, and reproducible. This is irrespective of the type of CIED, pacemaker dependancy or multiple 24-h scanning sessions. Our protocol addresses early detection of potential complications and establishes a response system for potential device-related complications. Our observation suggests that routine DFTT/DSMT post-MRI may not be necessary.

  8. Adaptation of the modified Bouc–Wen model to compensate for hysteresis in respiratory motion for the list-mode binning of cardiac SPECT and PET acquisitions: Testing using MRI

    International Nuclear Information System (INIS)

    Dasari, Paul K. R.; Shazeeb, Mohammed Salman; Könik, Arda; Lindsay, Clifford; Mukherjee, Joyeeta M.; Johnson, Karen L.; King, Michael A.

    2014-01-01

    Purpose: Binning list-mode acquisitions as a function of a surrogate signal related to respiration has been employed to reduce the impact of respiratory motion on image quality in cardiac emission tomography (SPECT and PET). Inherent in amplitude binning is the assumption that there is a monotonic relationship between the amplitude of the surrogate signal and respiratory motion of the heart. This assumption is not valid in the presence of hysteresis when heart motion exhibits a different relationship with the surrogate during inspiration and expiration. The purpose of this study was to investigate the novel approach of using the Bouc–Wen (BW) model to provide a signal accounting for hysteresis when binning list-mode data with the goal of thereby improving motion correction. The study is based on the authors’ previous observations that hysteresis between chest and abdomen markers was indicative of hysteresis between abdomen markers and the internal motion of the heart. Methods: In 19 healthy volunteers, they determined the internal motion of the heart and diaphragm in the superior–inferior direction during free breathing using MRI navigators. A visual tracking system (VTS) synchronized with MRI acquisition tracked the anterior–posterior motions of external markers placed on the chest and abdomen. These data were employed to develop and test the Bouc–Wen model by inputting the VTS derived chest and abdomen motions into it and using the resulting output signals as surrogates for cardiac motion. The data of the volunteers were divided into training and testing sets. The training set was used to obtain initial values for the model parameters for all of the volunteers in the set, and for set members based on whether they were or were not classified as exhibiting hysteresis using a metric derived from the markers. These initial parameters were then employed with the testing set to estimate output signals. Pearson’s linear correlation coefficient between the

  9. Dictionary-driven Ischemia Detection from Cardiac Phase-Resolved Myocardial BOLD MRI at Rest

    Science.gov (United States)

    Bevilacqua, Marco; Dharmakumar, Rohan; Tsaftaris, Sotirios A.

    2016-01-01

    Cardiac Phase-resolved Blood-Oxygen-Level Dependent (CP–BOLD) MRI provides a unique opportunity to image an ongoing ischemia at rest. However, it requires post-processing to evaluate the extent of ischemia. To address this, here we propose an unsupervised ischemia detection (UID) method which relies on the inherent spatio-temporal correlation between oxygenation and wall motion to formalize a joint learning and detection problem based on dictionary decomposition. Considering input data of a single subject, it treats ischemia as an anomaly and iteratively learns dictionaries to represent only normal observations (corresponding to myocardial territories remote to ischemia). Anomaly detection is based on a modified version of One-class Support Vector Machines (OCSVM) to regulate directly the margins by incorporating the dictionary-based representation errors. A measure of ischemic extent (IE) is estimated, reflecting the relative portion of the myocardium affected by ischemia. For visualization purposes an ischemia likelihood map is created by estimating posterior probabilities from the OCSVM outputs, thus obtaining how likely the classification is correct. UID is evaluated on synthetic data and in a 2D CP–BOLD data set from a canine experimental model emulating acute coronary syndromes. Comparing early ischemic territories identified with UID against infarct territories (after several hours of ischemia), we find that IE, as measured by UID, is highly correlated (Pearson’s r = 0.84) w.r.t. infarct size. When advances in automated registration and segmentation of CP–BOLD images and full coverage 3D acquisitions become available, we hope that this method can enable pixel-level assessment of ischemia with this truly non-invasive imaging technique. PMID:26292338

  10. Cost-effectiveness of functional cardiac imaging in the diagnostic work-up of coronary heart disease.

    Science.gov (United States)

    Pletscher, Mark; Walker, Simon; Moschetti, Karine; Pinget, Christophe; Wasserfallen, Jean-Blaise; Greenwood, John P; Schwitter, Juerg; Girardin, François R

    2016-07-01

    The aim of this study was to assess the cost-effectiveness of eight common diagnostic work-up strategies for coronary heart disease (CHD) in patients with stable angina symptoms in Switzerland. A decision analytical model was used to perform a cost-effectiveness comparison of eight common multitest strategies to diagnose CHD using combinations of four diagnostic techniques: exercise treadmill test (ETT), single-photon emission computed tomography (SPECT), cardiac magnetic resonance imaging (CMR), and coronary angiography (CA). We used a Markov state transition model to extrapolate the results over a life-time horizon, from a third-party payer perspective. We used a CHD prevalence rate of 39% in patients and a base-case scenario with 60-year-old male patients with intermediate symptom severity Canadian Cardiovascular Society grading of angina pectoris 2 and at least one cardiovascular (CV) risk factor but without a history of myocardial infarction and without need for revascularization. Among the eight work-up strategies, one strategy was dominant, i.e. least costly and most effective: ETT followed by CMR if the ETT result was inconclusive and then CA if the CMR result was positive or inconclusive. The CMR features a favourable balance between false-negative diagnoses, associated with an elevated risk of CV events, and false-positive diagnoses, leading to unnecessary CA and related mortality. Key parameters guiding the diagnostic strategy are the prevalence of CHD in patients with angina symptoms and the diagnostic costs of CA and CMR. Cardiac magnetic resonance imaging appears to be a cost-effective work-up strategy compared with other regimens using SPECT or direct CA. Cardiac magnetic resonance imaging should be more widely recommended as a diagnostic procedure for patients with suspected angina symptoms.

  11. Detection of an occult transclival cerebrospinal fluid fistula by CT and MRI

    International Nuclear Information System (INIS)

    Schick, B.; Brors, D.; Draf, W.; Goedecke, A.; Prescher, A.

    1998-01-01

    We describe an unusual occult transclival cerebrospinal fluid (CSF) fistula to the sphenoid sinus demonstrated by MRI. CT was performed because of a posterior cerebral infarct caused by cardiac arrhythmia. Axial sections showed fluid in the sphenoid sinus. High-resolution scans revealed a bony defect 3 mm in diameter of the posterior wall of the sphenoid sinus, and MRI showed a transclival CSF fistula. This occult lesion was confirmed by surgery and duraplasty was successfully performed via an endonasal approach. (orig.)

  12. R Wave in aVL Lead is a Robust Index of Left Ventricular Hypertrophy: A Cardiac MRI Study.

    Science.gov (United States)

    Courand, Pierre-Yves; Grandjean, Adrien; Charles, Paul; Paget, Vinciane; Khettab, Fouad; Bricca, Giampiero; Boussel, Loïc; Lantelme, Pierre; Harbaoui, Brahim

    2015-08-01

    In patients free from overt cardiac disease, R wave in aVL lead (RaVL) is strongly correlated with left ventricular mass index (LVMI) assessed by transthoracic echocardiography. The aim of the present study was to extend this finding to other settings (cardiomyopathy or conduction disorders), by comparing ECG criteria of left ventricular hypertrophy (LVH) to cardiac MRI (CMR). In 501 patients, CMR and ECG were performed within a median-period of 5 days. CMR LVH cut-offs used were 83 g/m2 in men and 67 g/m2 in women. RaVL was independently correlated with LVMI in patients with or without myocardial infarction (MI) (N = 300 and N = 201, respectively). SV3 was independently correlated with LVMI and LV enlargement only in patients without MI. In the whole cohort, RaVL had area under receiver-operating characteristic curve of 0.729 (specificity 98.3%, sensitivity 19.6%, optimal cut-off 1.1 mV). The performance of RaVL was remarkable in women, in Caucasians, and in the presence of right bundle branch block. It decreased in case of MI. Overall, it is proposed that below 0.5 mV and above 1.0 mV, RaVL is sufficient to exclude or establish LVH. Between 0.5 and 1 mV, composite indices (Cornell voltage or product) should be used. Using this algorithm allowed classifying appropriately 85% of the patients. Our results showed that RaVL is a good index of LVH with a univocal threshold of 1.0 mV in various clinical conditions. SV3 may be combined to RaVL in some conditions, namely LV enlargement to increase its performance. © American Journal of Hypertension, Ltd 2015. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Cardiac Catheterization (For Kids)

    Science.gov (United States)

    ... First Aid & Safety Doctors & Hospitals Videos Recipes for Kids Kids site Sitio para niños How the Body Works ... Educators Search English Español Cardiac Catheterization KidsHealth / For Kids / Cardiac Catheterization What's in this article? What Is ...

  14. Holding Biological Motion in Working Memory: An fMRI Study

    Directory of Open Access Journals (Sweden)

    Xiqian eLu

    2016-06-01

    Full Text Available Holding biological motion (BM, the movements of animate entities, in working memory (WM is important to our daily life activities. However, the neural substrates underlying the WM processing of BM remain largely unknown. Employing the functional magnetic resonance imaging (fMRI technique, the current study directly investigated this issue. We used point-light BM animations as the tested stimuli, and explored the neural substrates involved in encoding and retaining BM information in WM. Participants were required to remember two or four BM stimuli in a change-detection task. We first defined a set of potential brain regions devoted to the BM processing in WM in one experiment. We then conducted the second fMRI experiment, and performed time-course analysis over the pre-defined regions, which allowed us to differentiate the encoding and maintenance phases of WM. The results showed that a set of brain regions were involved in encoding BM into WM, including the middle frontal gyrus, inferior frontal gyrus, superior parietal lobule, inferior parietal lobule, superior temporal sulcus, fusiform gyrus, and middle occipital gyrus. However, only the middle frontal gyrus, inferior frontal gyrus, superior parietal lobule, and inferior parietal lobule were involved in retaining BM into WM. These results suggest that an overlapped network exists between the WM encoding and maintenance for BM; however, retaining BM in WM predominately relies on the mirror neuron system.

  15. Non-white noise in fMRI: Does modelling have an impact?

    DEFF Research Database (Denmark)

    Lund, Torben Ellegaard; Madsen, Kristoffer Hougaard; Sidaros, Karam

    2006-01-01

    are typically modelled as an autoregressive (AR) process. In this paper, we propose an alternative approach: Nuisance Variable Regression (NVR). By inclusion of confounding effects in a general linear model (GLM), we first confirm that the spatial distribution of the various fMRI noise sources is similar......The sources of non-white noise in Blood Oxygenation Level Dependent (BOLD) functional magnetic resonance imaging (fMRI) are many. Familiar sources include low-frequency drift due to hardware imperfections, oscillatory noise due to respiration and cardiac pulsation and residual movement artefacts...

  16. The best of nuclear cardiology and MRI in 2003

    International Nuclear Information System (INIS)

    Daou, D.

    2005-01-01

    As in previous years, the year 2003 was notable for clinical studies confirming the position occupied by Nuclear Cardiology and MRI in patient management. This was confirmed in the different areas tackled this year. In myocardial ischaemia, 2 points attracted our attention. Firstly, there is the good prognostic value of a normal myocardial perfusion (stress) CT with tetrofosmin (Myoview), which makes the good prognostic value of a normal SPECT independent of the type of tracer used ( 201 Tl, 99m Tc - MIBI, 99m Tc - Tetrofosmine). Secondly, an elegant study performed in 10627 patients, once more confirming the significance of using stress SPECT in the therapeutic strategy (medical treatment versus revascularization). Furthermore, in the area of myocardial infarction (MI), 3 points attracted our attention : the use of Annexin A5 - 99m Tc was advantageous for visualizing apoptosis in the territory at risk, the limits of studying regional myocardial function versus contrast MRI in the diagnosis of MI, and the good sensitivity of contrast MRI in the detection of sub-endocardial MI. In the diagnosis of acute coronary syndrome, one study reported the sensitivity and specificity of emergency MRI (84 versus 85%). In the area of myocardial viability, one study reported the inferiority of electromechanical mapping compared to SPECT and positron emission tomography. In the area of post-infarct cardiac failure, studies have confirmed the place of LVEF in the evaluation of prognosis, and combining this with BNP and possibly the study of the angiotensin converting enzyme gene. Similarly another study reported the superiority of MIBG-1231 compared to cardiac frequency variability in the evaluation of prognosis. (author)

  17. Multi-slice CT (MSCT) in cardiac function imaging: threshold-value-supported 3D volume reconstructions to determine the left ventricular ejection fraction in comparison to MRI

    International Nuclear Information System (INIS)

    Ehrhard, K.; Oberholzer, K.; Gast, K.; Mildenberger, P.; Kreitner, K.F.; Thelen, M.

    2002-01-01

    Purpose: To assess MSCT of the heart to determining left ventricular ejection fraction (EF) based on threshold-value-supported 3D volume reconstructions compared to MRI. Methods: Cardiac MSCT was performed in 7 patients. Images were reconstructed during end-systolic and end-diastolic phases of the cardiac cycle and transformed to 3D volumes to determine end-systolic (ESV) and end-diastolic volume (EDV) by using different lower threshold values: besides fixed lower threshold values, identical for each image sequence, individual lower threshold values dependent on contrast enhancement of the left ventricle were applied. The latter represent the mean value calculated by combining the average CT-density of the myocardium and the contrast-enhanced blood in the left ventricle. The EF derived from ESV and EDV. Results: The best correlation with MR imaging was obtained for ESV and EDV by using the individual lower threshold values for the respective sequence. The correlation coefficient for ESV was 0.95 and for EDV it was 0.93. On average, the ESV was overestimated by 3.72 ml, while the ESD was underestimated by 2.85 ml. The respective standard deviation for the ESV was 14,87 ml, for the EDV it was 26.83 ml. On average, the EF was underestimated by 3.57% with a standard deviation of 9.43% and a correlation coefficient of 0.83 in comparison to MRI. Conclusion: The threshold-value-supported 3D volume reconstruction of the left ventricle represents a good method to determine the left ventricular function parameters. Due to the differences in the contrast enhancement, the use of an individual lower threshold value for every image sequence is of particular importance. (orig.) [de

  18. Restoration of fMRI Decodability Does Not Imply Latent Working Memory States

    Science.gov (United States)

    Schneegans, Sebastian; Bays, Paul M.

    2018-01-01

    Recent imaging studies have challenged the prevailing view that working memory is mediated by sustained neural activity. Using machine learning methods to reconstruct memory content, these studies found that previously diminished representations can be restored by retrospective cueing or other forms of stimulation. These findings have been interpreted as evidence for an activity-silent working memory state that can be reactivated dependent on task demands. Here, we test the validity of this conclusion by formulating a neural process model of working memory based on sustained activity and using this model to emulate a spatial recall task with retrocueing. The simulation reproduces both behavioral and fMRI results previously taken as evidence for latent states, in particular the restoration of spatial reconstruction quality following an informative cue. Our results demonstrate that recovery of the decodability of an imaging signal does not provide compelling evidence for an activity-silent working memory state. PMID:28820674

  19. Determination of left ventricular function parameters and myocardial mass: comparison of MRI and EBT

    International Nuclear Information System (INIS)

    Kivelitz, D.E.; Enzweiler, C.N.H.; Wiese, T.H.; Lembcke, A.; Taupitz, M.; Hamm, B.; Borges, A.; Zytowski, M.

    2000-01-01

    Purpose: Comparative volumetric assessment of the left ventricle by magnetic resonance imaging (MRI) and electron beam tomography (EBT) in patients with ischemic and dilated cardiac disease. Methods: Thirty-two patients underwent cine MRI and EBT in the multislice mode. All studies were triggered to the ECG. Left ventricular ejection fraction (EF), enddiastolic (EDV) and endsystolic volume (ESV), and myocardial mass (MM) were determined by 3D-volumetry by MRI and EBT and results were compared. Results: The correlation between MRI and EBT for EF, EDV, ESV, and MM were r=0.86, r=0.95, r=0.95, and r=0.93, respectively. Conclusions: There is an excellent correlation between MRI and EBT in determining left-ventricular parameters. Both methods are suitable for volumetric assessment of the left ventricie. (orig.) [de

  20. Extended Remediation of Sleep Deprived-Induced Working Memory Deficits Using fMRI-guided Transcranial Magnetic Stimulation

    Science.gov (United States)

    Luber, Bruce; Steffener, Jason; Tucker, Adrienne; Habeck, Christian; Peterchev, Angel V.; Deng, Zhi-De; Basner, Robert C.; Stern, Yaakov; Lisanby, Sarah H.

    2013-01-01

    Study Objectives: We attempted to prevent the development of working memory (WM) impairments caused by sleep deprivation using fMRI-guided repetitive transcranial magnetic stimulation (rTMS). Novel aspects of our fMRI-guided rTMS paradigm included the use of sophisticated covariance methods to identify functional networks in imaging data, and the use of fMRI-targeted rTMS concurrent with task performance to modulate plasticity effects over a longer term. Design: Between-groups mixed model. Setting: TMS, MRI, and sleep laboratory study. Participants: 27 subjects (13 receiving Active rTMS, and 14 Sham) completed the sleep deprivation protocol, with another 21 (10 Active, 11 Sham) non-sleep deprived subjects run in a second experiment. Interventions: Our previous covariance analysis had identified a network, including occipital cortex, which demonstrated individual differences in resilience to the deleterious effects of sleep deprivation on WM performance. Five Hz rTMS was applied to left lateral occipital cortex while subjects performed a WM task during 4 sessions over the course of 2 days of total sleep deprivation. Measurements and Results: At the end of the sleep deprivation period, Sham sleep deprived subjects exhibited degraded performance in the WM task. In contrast, those receiving Active rTMS did not show the slowing and lapsing typical in sleep deprivation, and instead performed similarly to non- sleep deprived subjects. Importantly, the Active sleep deprivation group showed rTMS-induced facilitation of WM performance a full 18 hours after the last rTMS session. Conclusions: Over the course of sleep deprivation, these results indicate that rTMS applied concurrently with WM task performance affected neural circuitry involved in WM to prevent its full impact. Citation: Luber B; Steffener J; Tucker A; Habeck C; Peterchev AV; Deng ZD; Basner RC; Stern Y; Lisanby SH. Extended remediation of sleep deprived-induced working memory deficits using fMRI

  1. Head MRI

    Science.gov (United States)

    ... hearing aids Pins, hairpins, metal zippers, and similar metallic items Removable dental work How the Test will ... an MRI can make heart pacemakers and other implants not work as well. It can also cause ...

  2. Effect of fMRI acoustic noise on non-auditory working memory task: comparison between continuous and pulsed sound emitting EPI.

    Science.gov (United States)

    Haller, Sven; Bartsch, Andreas J; Radue, Ernst W; Klarhöfer, Markus; Seifritz, Erich; Scheffler, Klaus

    2005-11-01

    Conventional blood oxygenation level-dependent (BOLD) based functional magnetic resonance imaging (fMRI) is accompanied by substantial acoustic gradient noise. This noise can influence the performance as well as neuronal activations. Conventional fMRI typically has a pulsed noise component, which is a particularly efficient auditory stimulus. We investigated whether the elimination of this pulsed noise component in a recent modification of continuous-sound fMRI modifies neuronal activations in a cognitively demanding non-auditory working memory task. Sixteen normal subjects performed a letter variant n-back task. Brain activity and psychomotor performance was examined during fMRI with continuous-sound fMRI and conventional fMRI. We found greater BOLD responses in bilateral medial frontal gyrus, left middle frontal gyrus, left middle temporal gyrus, left hippocampus, right superior frontal gyrus, right precuneus and right cingulate gyrus with continuous-sound compared to conventional fMRI. Conversely, BOLD responses were greater in bilateral cingulate gyrus, left middle and superior frontal gyrus and right lingual gyrus with conventional compared to continuous-sound fMRI. There were no differences in psychomotor performance between both scanning protocols. Although behavioral performance was not affected, acoustic gradient noise interferes with neuronal activations in non-auditory cognitive tasks and represents a putative systematic confound.

  3. MRI Visualization of Staphyloccocus aureus-Induced Infective Endocarditis in Mice

    Science.gov (United States)

    Ring, Janine; Hoerr, Verena; Tuchscherr, Lorena; Kuhlmann, Michael T.; Löffler, Bettina; Faber, Cornelius

    2014-01-01

    Infective endocarditis (IE) is a severe and often fatal disease, lacking a fast and reliable diagnostic procedure. The purpose of this study was to establish a mouse model of Staphylococcus aureus-induced IE and to develop a MRI technology to characterize and diagnose IE. To establish the mouse model of hematogenous IE, aortic valve damage was induced by placing a permanent catheter into right carotid artery. 24 h after surgery, mice were injected intravenously with either iron particle-labeled or unlabeled S. aureus (strain 6850). To distinguish the effect of IE from mere tissue injury or recruited macrophages, subgroups of mice received sham surgery prior to infection (n = 17), received surgery without infection (n = 8), or obtained additionally injection of free iron particles to label macrophages (n = 17). Cardiac MRI was performed 48 h after surgery using a self-gated ultra-short echo time (UTE) sequence (TR/TE, 5/0.31 ms; in-plane/slice, 0.125/1 mm; duration, 12∶08 min) to obtain high-resolution, artifact-free cinematographic images of the valves. After MRI, valves were either homogenized and plated on blood agar plates for determination of bacterial titers, or sectioned and stained for histology. In the animal model, both severity of the disease and mortality increased with bacterial numbers. Infection with 105 S. aureus bacteria reliably caused endocarditis with vegetations on the valves. Cinematographic UTE MRI visualised the aortic valve over the cardiac cycle and allowed for detection of bacterial vegetations, while mere tissue trauma or labeled macrophages were not detected. Iron labeling of S. aureus was not required for detection. MRI results were consistent with histology and microbial assessment. These data showed that S. aureus-induced IE in mice can be detected by MRI. The established mouse model allows for investigation of the pathophysiology of IE, testing of novel drugs and may serve for the development of a clinical diagnostic

  4. Detection of an occult transclival cerebrospinal fluid fistula by CT and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Schick, B.; Brors, D.; Draf, W. [Department of Ear, Nose and Throat Diseases, Head, Neck and Facial Plastic Surgery, Marburg Univ. (Germany); Goedecke, A. [Department of Radiology, Academic Teaching Hospital, Fulda (Germany); Prescher, A. [Department of Anatomy and Embryology, University Medical School, RWTH, Aachen (Germany)

    1998-12-01

    We describe an unusual occult transclival cerebrospinal fluid (CSF) fistula to the sphenoid sinus demonstrated by MRI. CT was performed because of a posterior cerebral infarct caused by cardiac arrhythmia. Axial sections showed fluid in the sphenoid sinus. High-resolution scans revealed a bony defect 3 mm in diameter of the posterior wall of the sphenoid sinus, and MRI showed a transclival CSF fistula. This occult lesion was confirmed by surgery and duraplasty was successfully performed via an endonasal approach. (orig.) With 3 figs., 19 refs.

  5. MRI of the Chest

    Medline Plus

    Full Text Available ... items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a ...

  6. Enhanced control of dorsolateral prefrontal cortex neurophysiology with real-time functional magnetic resonance imaging (rt-fMRI) neurofeedback training and working memory practice.

    Science.gov (United States)

    Sherwood, Matthew S; Kane, Jessica H; Weisend, Michael P; Parker, Jason G

    2016-01-01

    Real-time functional magnetic resonance imaging (rt-fMRI) neurofeedback can be used to train localized, conscious regulation of blood oxygen level-dependent (BOLD) signals. As a therapeutic technique, rt-fMRI neurofeedback reduces the symptoms of a variety of neurologic disorders. To date, few studies have investigated the use of self-regulation training using rt-fMRI neurofeedback to enhance cognitive performance. This work investigates the utility of rt-fMRI neurofeedback as a tool to enhance human cognition by training healthy individuals to consciously control activity in the left dorsolateral prefrontal cortex (DLPFC). A cohort of 18 healthy participants in the experimental group underwent rt-fMRI neurofeedback from the left DLPFC in five training sessions across two weeks while 7 participants in the control group underwent similar training outside the MRI and without rt-fMRI neurofeedback. Working memory (WM) performance was evaluated on two testing days separated by the five rt-fMRI neurofeedback sessions using two computerized tests. We investigated the ability to control the BOLD signal across training sessions and WM performance across the two testing days. The group with rt-fMRI neurofeedback demonstrated a significant increase in the ability to self-regulate the BOLD signal in the left DLPFC across sessions. WM performance showed differential improvement between testing days one and two across the groups with the highest increases observed in the rt-fMRI neurofeedback group. These results provide evidence that individuals can quickly gain the ability to consciously control the left DLPFC, and this training results in improvements of WM performance beyond that of training alone. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  7. FDG PET-CT findings of extra-thoracic sarcoid are associated with cardiac sarcoid: A rationale for using FGD PET-CT for cardiac sarcoid evaluation.

    Science.gov (United States)

    Patel, Darshan C; Gunasekaran, Senthil S; Goettl, Christopher; Sweiss, Nadera J; Lu, Yang

    2017-07-05

    This retrospective study investigates the relationship between cardiac and extra-thoracic sarcoid findings on FDG PET-CT using a 72-hour pretest high-fat, high-protein, and very low-carbohydrate (HFHPVLC) diet. A total of 196 consecutive FDG PET-CT scans with 72-hour HFHPVLC diet preparation were performed between December 2014 and December 2015 in known sarcoid patients. Of these scans, 5 were excluded for non-adherence to diet preparation or underlying cancer. Cardiac and extra-thoracic sarcoid lesions were categorized and measured for radiotracer uptake. A total of 188 patients had 191 eligible FDG PET/CT scans (3 follow-up scans), of which there were 20 (10%) positive, 6 indeterminate (3%), and 165 (86%) negative for CS. Among the 20 scans positive for CS, 8 (40%) had findings of both cardiac and extra-thoracic sarcoid. Our study shows that 40% of CS patients also have FDG PET-CT findings of extra-thoracic sarcoid. This makes an intriguing case for FDG PET-CT use with pretest diet prep over cardiac MRI (CMR) for cardiac sarcoid evaluation, given that CMR is likely to overlook these extra-thoracic sites of disease.

  8. MRI evaluation of maternal cardiac displacement in pregnancy: implications for cardiopulmonary resuscitation.

    Science.gov (United States)

    Holmes, Signy; Kirkpatrick, Iain D C; Zelop, Carolyn M; Jassal, Davinder S

    2015-09-01

    The purpose of this study was to determine, with the use of cardiac magnetic resonance imaging, whether there is vertical displacement of the heart during pregnancy. Cardiopulmonary resuscitation guidelines during pregnancy recommend placing the hands 2-3 cm higher on the sternum than in nonpregnant individuals. This recommendation is based on the presumption that the heart is displaced superiorly by the diaphragm during the third trimester. Whether there is true cardiac displacement because of the expanding uterus in pregnancy remains unknown. A total of 34 healthy female volunteers 18-35 years old were enrolled prospectively from 2010-2012 at 2 tertiary care centers. The conditions of all participants were evaluated with cardiac magnetic resonance imaging in the one-half left lateral decubitus position during the third trimester of pregnancy and again at a minimum of 3 months after delivery (surrogate for the nonpregnant state). Superior displacement of the heart was determined by measurement of the distance between the inferior aspect of the clavicular heads and the coronary sinus at both time points. The study population included 34 women (mean age, 29 ± 3 years; body mass index, 24 ± 4 kg/m(2)). The mean gestational age at third-trimester imaging was 237 ± 16 days (34 weeks ± 16 days); the mean number of days for postpartum imaging (baseline) was 107 ± 25 days (16 weeks ± 25 days). There was no statistical difference between the cardiac position at baseline (10.1 ± 1.2 cm) and during the third trimester (10.3 ± 1.1 cm; P = .22). Contrary to popular assumption, there is no significant vertical displacement of the heart in the third trimester of pregnancy relative to the nonpregnant state. Accordingly, there is no need to alter hand placement for chest compressions during cardiopulmonary resuscitation in pregnancy. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Design, operation, and safety of single-room interventional MRI suites: practical experience from two centers.

    Science.gov (United States)

    White, Mark J; Thornton, John S; Hawkes, David J; Hill, Derek L G; Kitchen, Neil; Mancini, Laura; McEvoy, Andrew W; Razavi, Reza; Wilson, Sally; Yousry, Tarek; Keevil, Stephen F

    2015-01-01

    The design and operation of a facility in which a magnetic resonance imaging (MRI) scanner is incorporated into a room used for surgical or endovascular cardiac interventions presents several challenges. MR safety must be maintained in the presence of a much wider variety of equipment than is found in a diagnostic unit, and of staff unfamiliar with the MRI environment, without compromising the safety and practicality of the interventional procedure. Both the MR-guided cardiac interventional unit at Kings College London and the intraoperative imaging suite at the National Hospital for Neurology and Neurosurgery are single-room interventional facilities incorporating 1.5 T cylindrical-bore MRI scanners. The two units employ similar strategies to maintain MR safety, both in original design and day-to-day operational workflows, and between them over a decade of incident-free practice has been accumulated. This article outlines these strategies, highlighting both similarities and differences between the units, as well as some lessons learned and resulting procedural changes made in both units since installation. © 2014 Wiley Periodicals, Inc.

  10. Subclinical Disease Burden as Assessed by Whole-Body MRI in Subjects With Prediabetes, Subjects With Diabetes, and Normal Control Subjects From the General Population: The KORA-MRI Study.

    Science.gov (United States)

    Bamberg, Fabian; Hetterich, Holger; Rospleszcz, Susanne; Lorbeer, Roberto; Auweter, Sigrid D; Schlett, Christopher L; Schafnitzel, Anina; Bayerl, Christian; Schindler, Andreas; Saam, Tobias; Müller-Peltzer, Katharina; Sommer, Wieland; Zitzelsberger, Tanja; Machann, Jürgen; Ingrisch, Michael; Selder, Sonja; Rathmann, Wolfgang; Heier, Margit; Linkohr, Birgit; Meisinger, Christa; Weber, Christian; Ertl-Wagner, Birgit; Massberg, Steffen; Reiser, Maximilian F; Peters, Annette

    2017-01-01

    Detailed pathophysiological manifestations of early disease in the context of prediabetes are poorly understood. This study aimed to evaluate the extent of early signs of metabolic and cardio-cerebrovascular complications affecting multiple organs in individuals with prediabetes. Subjects without a history of stroke, coronary artery disease, or peripheral artery disease were enrolled in a case-control study nested within the Cooperative Health Research in the Region of Augsburg (KORA) FF4 cohort and underwent comprehensive MRI assessment to characterize cerebral parameters (white matter lesions, microbleeds), cardiovascular parameters (carotid plaque, left ventricular function, and myocardial late gadolinium enhancement [LGE]), and metabolic parameters (hepatic proton-density fat fraction [PDFF] and subcutaneous and visceral abdominal fat). Among 400 subjects who underwent MRI, 103 subjects had prediabetes and 54 had established diabetes. Subjects with prediabetes had an increased risk for carotid plaque and adverse functional cardiac parameters, including reduced early diastolic filling rates as well as a higher prevalence of LGE compared with healthy control subjects. In addition, people with prediabetes had significantly elevated levels of PDFF and total and visceral fat. Thus, subjects with prediabetes show early signs of subclinical disease that include vascular, cardiac, and metabolic changes, as measured by whole-body MRI after adjusting for cardiometabolic risk factors. © 2017 by the American Diabetes Association.

  11. MRI of the Chest

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings ... tomography (CT) scans, MRI does not utilize ionizing radiation. Instead, radiofrequency pulses re-align hydrogen atoms that ...

  12. Dynamic change in size of the lateral ventricle evaluated by cine MRI

    International Nuclear Information System (INIS)

    Abe, Toshi

    1990-01-01

    CSF pulsation suggests variation in the size of the cerebral ventricle during the cardiac cycle. CINE MRI, which is a useful technique for observation of the pulsatile CSF flow, demonstrates a dynamic change in size of the lateral ventricle. CINE MRI was performed on a 0.5 tesla MR imaging system (SMT-50, SHIMADZU). Sixteen different phased images during cardiac cycle were made by a gradient acho technique (STAGE: Short Tip Angle Gradient Echo, TE=14 msec, Flip Angle=30deg). From the measurement of the lateral ventricular areas of two different phases of CINE MRI during cadiac cycle, variation rate of cerebral ventricular area (VRCVA) was calculated. Twenty-five normal volunteers (14 younger adults aged 27-44 years, 11 older adults aged 56-73 years) and six cases of marked diffuse cerebral atrophy were studied. The results included: The mean VRCVA of younger adults was 14.4% (at right body of lateral ventricle) ∼ 30.0% (at left anterior horn of lateral ventricle). The mean VRCVA of younger adults is higher than the mean VRCVA of older adults. In the cases of marked diffuse cerebral atrophy, the mean VRCVA was very lower than the mean VRCVA of older adults. VRCVA of lateral ventricle calculated from CINE MRI seemed to have a good relationship to the brain elasticity. This noninvasive method would be used as an indication of the elastic response of the ventricles and the surrounding brain. (J.P.N.)

  13. Clinical evaluation of cardiovascular disease by gated-MRI (magnetic resonance imaging) in the operating field of 0.35 and 1.5 Tesla

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Naito, Hiroaki; Yamada, Yukinori; Kozuka, Takahiro

    1985-01-01

    To evaluate the clinical usefulness of magnetic resonance imaging (MRI) in the cardiovascular disease, 21 patients were examined using 0.35 and 1.5 Tesla superconductive type (Magnetom, Siemens). In our study, all patients were performed using ECG-gated MRI. Therefore, the cardiac chambers were discriminated clearly from the myocardial wall compared to non-gated MRI. Gated-MRI was performed in 6 normal persons in the operating field at 0.35 and 1.5 Tesla. The image of the latter showed superior than that of the former because of high S/N ratio. In myocardial infarction, infarct area was demonstrated as the wall thinning in 4 of 5 patients. Hypertrophic cardiomyopathy showed thickened left ventricle associated with its narrowed cavity in 7 patients. In the remaining such as congenital and valvular heart disease, global and regional cardiac morphology were assessed noninvasively by gated MRI. In addition, gated MRI was also applied to the diagnosis of peripheral vascular diseases. In dissecting aneurysm, double channels with an intimal flap in the aorta were clearly visualized. And in the aortitis syndrome, aortic dilatation and stenosis were also assessed noninvasively. In conclusion, gated MRI in diagnosing various abnormalities of cardiovascular disease was confirmed. (author)

  14. Susac’s Syndrome: A Case with Unusual Cardiac Vestibular and Imaging Manifestations

    Directory of Open Access Journals (Sweden)

    Yaron River

    2015-01-01

    Full Text Available Susac’s syndrome (SS is a disease of the microvasculature of the retina, brain, and inner ear. We describe a patient with unusual manifestations of SS with possible involvement of the brainstem, cardiac arrhythmia, and MRI findings lacking the characteristic lesions found in Susac’s syndrome.

  15. Verbal to visual code switching improves working memory in older adults: An fMRI study

    Directory of Open Access Journals (Sweden)

    Mariko eOsaka

    2012-02-01

    Full Text Available The effects of verbal to visual code switching training on working memory performance were investigated in the elderly. Twenty-five elderly people were introduced to a verbal to visual code switching strategy (training group while the other 25 were not (control group. During this strategy training period, participants in the training group practiced focusing their attention on a target word both by drawing the target’s figure and by forming mental images of the target. To explore the neural substrates underlying strategy effects, fMRI was used to measure brain activity of the elderly in both groups while they performed a working memory task (reading span test, RST, before and after the attention training period. RST recognition accuracy was enhanced only in the training group. fMRI data for this group showed increased activation in the anterior cingulate cortex (ACC, a region that typically shows activation in young adults performing the RST. Furthermore, activation was found both in the left and right inferior parietal lobule (IPL and right superior parietal lobule (SPL, while there was no activation in these areas for the control group. These findings suggest that using a strategy of verbal to visual code switching helped the elderly participants to maintain the words in working memory.

  16. MRI of the Chest

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a few types. ...

  17. Self-gated golden-angle spiral 4D flow MRI.

    Science.gov (United States)

    Bastkowski, Rene; Weiss, Kilian; Maintz, David; Giese, Daniel

    2018-01-17

    The acquisition of 4D flow magnetic resonance imaging (MRI) in cardiovascular applications has recently made large progress toward clinical feasibility. The need for simultaneous compensation of cardiac and breathing motion still poses a challenge for widespread clinical use. Especially, breathing motion, addressed by gating approaches, can lead to unpredictable and long scan times. The current work proposes a time-efficient self-gated 4D flow sequence that exploits up to 100% of the acquired data and operates at a predictable scan time. A self-gated golden-angle spiral 4D flow sequence was implemented and tested in 10 volunteers. Data were retrospectively binned into respiratory and cardiac states and reconstructed using a conjugate-gradient sensitivity encoding reconstruction. Net flow curves, stroke volumes, and peak flow in the aorta were evaluated and compared to a conventional Cartesian 4D flow sequence. Additionally, flow quantities reconstructed from 50% to 100% of the self-gated 4D flow data were compared. Self-gating signals for respiratory and cardiac motion were extracted for all volunteers. Flow quantities were in agreement with the standard Cartesian scan. Mean differences in stroke volumes and peak flow of 7.6 ± 11.5 and 4.0 ± 79.9 mL/s were obtained, respectively. By retrospectively increasing breathing navigator efficiency while decreasing acquisition times (15:06-07:33 minutes), 50% of the acquired data were sufficient to measure stroke volumes with errors under 9.6 mL. The feasibility to acquire respiratory and cardiac self-gated 4D flow data at a predictable scan time was demonstrated. Magn Reson Med, 2018. © 2018 International Society for Magnetic Resonance in Medicine. © 2018 International Society for Magnetic Resonance in Medicine.

  18. Measurement of functional capacity requirements to aid in development of an occupation-specific rehabilitation training program to help firefighters with cardiac disease safely return to work.

    Science.gov (United States)

    Adams, Jenny; Roberts, Joanne; Simms, Kay; Cheng, Dunlei; Hartman, Julie; Bartlett, Charles

    2009-03-15

    We designed a study to measure the functional capacity requirements of firefighters to aid in the development of an occupation-specific training program in cardiac rehabilitation; 23 healthy male firefighters with no history of heart disease completed a fire and rescue obstacle course that simulated 7 common firefighting tasks. They wore complete personal protective equipment and portable metabolic instruments that included a data collection mask. We monitored each subject's oxygen consumption (VO(2)) and working heart rate, then calculated age-predicted maximum heart rates (220 - age) and training target heart rates (85% of age-predicted maximum heart rate). During performance of the obstacle course, the subjects' mean working heart rates and peak heart rates were higher than the calculated training target heart rates (t(22) = 5.69 [working vs target, p functional capacity greatly exceeded that typically attained by patients in traditional cardiac rehabilitation programs (5 to 8 METs). In conclusion, our results indicate the need for intense, occupation-specific cardiac rehabilitation training that will help firefighters safely return to work after a cardiac event.

  19. Working memory capacity and the functional connectome - insights from resting-state fMRI and voxelwise centrality mapping.

    Science.gov (United States)

    Markett, Sebastian; Reuter, Martin; Heeren, Behrend; Lachmann, Bernd; Weber, Bernd; Montag, Christian

    2018-02-01

    The functional connectome represents a comprehensive network map of functional connectivity throughout the human brain. To date, the relationship between the organization of functional connectivity and cognitive performance measures is still poorly understood. In the present study we use resting-state functional magnetic resonance imaging (fMRI) data to explore the link between the functional connectome and working memory capacity in an individual differences design. Working memory capacity, which refers to the maximum amount of context information that an individual can retain in the absence of external stimulation, was assessed outside the MRI scanner and estimated based on behavioral data from a change detection task. Resting-state time series were analyzed by means of voxelwise degree and eigenvector centrality mapping, which are data-driven network analytic approaches for the characterization of functional connectivity. We found working memory capacity to be inversely correlated with both centrality in the right intraparietal sulcus. Exploratory analyses revealed that this relationship was putatively driven by an increase in negative connectivity strength of the structure. This resting-state connectivity finding fits previous task based activation studies that have shown that this area responds to manipulations of working memory load.

  20. Statistical feature extraction for artifact removal from concurrent fMRI-EEG recordings.

    Science.gov (United States)

    Liu, Zhongming; de Zwart, Jacco A; van Gelderen, Peter; Kuo, Li-Wei; Duyn, Jeff H

    2012-02-01

    We propose a set of algorithms for sequentially removing artifacts related to MRI gradient switching and cardiac pulsations from electroencephalography (EEG) data recorded during functional magnetic resonance imaging (fMRI). Special emphasis is directed upon the use of statistical metrics and methods for the extraction and selection of features that characterize gradient and pulse artifacts. To remove gradient artifacts, we use channel-wise filtering based on singular value decomposition (SVD). To remove pulse artifacts, we first decompose data into temporally independent components and then select a compact cluster of components that possess sustained high mutual information with the electrocardiogram (ECG). After the removal of these components, the time courses of remaining components are filtered by SVD to remove the temporal patterns phase-locked to the cardiac timing markers derived from the ECG. The filtered component time courses are then inversely transformed into multi-channel EEG time series free of pulse artifacts. Evaluation based on a large set of simultaneous EEG-fMRI data obtained during a variety of behavioral tasks, sensory stimulations and resting conditions showed excellent data quality and robust performance attainable with the proposed methods. These algorithms have been implemented as a Matlab-based toolbox made freely available for public access and research use. Published by Elsevier Inc.

  1. Multimodality assessment of cardiac involvement in Churg-Strauss syndrome patients in clinical remission

    International Nuclear Information System (INIS)

    Szczeklik, W.; Miszalski-Jamka, T.; Mastalerz, L.; Sokolowska, B.; Dropinski, J.; Musial, J.; Banys, R.; Hor, K.N.; Mazur, W.

    2011-01-01

    Cardiac involvement in Churg-Strauss syndrome (CSS) is not uncommon, but its frequency varies widely and may depend on the activity of the disease. Therefore, the cardiac involvement in CSS patients in clinical remission was assessed in the present study. In 20 CSS patients in remission and 20 sex- and age-matched healthy controls, an electrocardiogram (ECG) stress test, echocardiography, and 24-h ECG Holter monitoring were performed, together with cardiac magnetic resonance imaging (cMRI). Cardiac involvement was present in 90% (18/20) of CSS patients. Left ventricular ejection fraction (LVEF) was on average lower in the CSS group than in controls (P<0.05), with 7 patients showing systolic heart failure (LVEF <50%). cMRI changes included late gadolinium enhancement lesions in the LV in 89% of patients (17/19), present in all layers of the myocardium. Signs of ongoing inflammation (early gadolinium enhancement) and edema (T2-weighted imaging) were present in 6/19 patients. Holter monitoring revealed both supraventricular and ventricular arrhythmias more frequently in CSS patients when compared with controls (P<0.05). Absolute eosinophil count before the initiation of treatment was higher in rhythm disturbances (P<0.05), and inversely correlated with LV systolic function (rho -0.65). Heart involvement in CSS patients who are in clinical remission is very common. It is characterized not only by fibrosis, but also by an active inflammatory process. The latter finding might influence therapeutic decisions in CSS patients in full clinical remission. (author)

  2. Multimodality assessment of cardiac involvement in Churg-Strauss syndrome patients in clinical remission

    Energy Technology Data Exchange (ETDEWEB)

    Szczeklik, W; Miszalski-Jamka, T; Mastalerz, L; Sokolowska, B; Dropinski, J; Musial, J [Medical Coll., Jagiellonian Univ., Krakow (Poland); Banys, R [John Paul II Hospital, Krakow (Poland); Hor, K N [Cincinnati Children' s Medical Center, OH (United States); Mazur, W [Heart and Vascular Center at The Christ Hospitals, OH (United States)

    2011-02-15

    Cardiac involvement in Churg-Strauss syndrome (CSS) is not uncommon, but its frequency varies widely and may depend on the activity of the disease. Therefore, the cardiac involvement in CSS patients in clinical remission was assessed in the present study. In 20 CSS patients in remission and 20 sex- and age-matched healthy controls, an electrocardiogram (ECG) stress test, echocardiography, and 24-h ECG Holter monitoring were performed, together with cardiac magnetic resonance imaging (cMRI). Cardiac involvement was present in 90% (18/20) of CSS patients. Left ventricular ejection fraction (LVEF) was on average lower in the CSS group than in controls (P<0.05), with 7 patients showing systolic heart failure (LVEF <50%). cMRI changes included late gadolinium enhancement lesions in the LV in 89% of patients (17/19), present in all layers of the myocardium. Signs of ongoing inflammation (early gadolinium enhancement) and edema (T2-weighted imaging) were present in 6/19 patients. Holter monitoring revealed both supraventricular and ventricular arrhythmias more frequently in CSS patients when compared with controls (P<0.05). Absolute eosinophil count before the initiation of treatment was higher in rhythm disturbances (P<0.05), and inversely correlated with LV systolic function (rho -0.65). Heart involvement in CSS patients who are in clinical remission is very common. It is characterized not only by fibrosis, but also by an active inflammatory process. The latter finding might influence therapeutic decisions in CSS patients in full clinical remission. (author)

  3. MRI of the Chest

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a few types. People with the ...

  4. Evaluation of valvular regurgitation by cine magnetic resonance imaging in patients with various cardiac diseases

    International Nuclear Information System (INIS)

    Kubota, Shuuhei; Nishimura, Tsunehiko

    1990-01-01

    In order to evaluate the clinical value and limitation of magnetic resonance imaging (MRI) for detection and quantification of valvular regurgitation, 98 patients with various cardiac diseases were studied by cine MRI and the results were compared with contrast angiography and doppler color-flow imaging. Cine MRI was carried out using FLASH (fast low angle shot) which employs TE of 10∼20 msec and TR of 30∼40 msec. 22 transverse tomograms per cardiac cycle with a slice thickness of 10 mm were obtained at the level of atrium and ventricle. The jet of valvular regurgitation was easily seen as a discrete are of low signal with cine MRI. Identification of the regurgitation and its severity were visually evaluated based on the relative size of the regurgitant jet from the incompetent valve orifice. Using contrast angiography as a gold standard, the sensitivity of cine MRI for detecting mitral regurgitation was 83% and was 94% for aortic regurgitation, with the specificity of 82% and 100%, respectively. For mitral requrgitation and aortic regurgitation, evaluation by cine MRI and severity agreed well with contrast angiography. By the comparative study with doppler color-flow imaging, relatively good agreement was found between the two methods in detection and quantitative evaluation of valvular regurgitation in any of four valves. Cine MRI was suggested to be useful for both the detection and semiquantification of valvular regurgitation in generally, but its clinical limitation at this point was also found because, 1)its images are not acquired in real times, as in contrast angiography or doppler color-flow imaging, but are compiled from the cumulative information from 128 heart beats, 2)the evaluation of regurgitation is made from only two-dimensional transverse tomograms. (author)

  5. Non-gated fetal MRI of umbilical blood flow in an acardiac twin

    Energy Technology Data Exchange (ETDEWEB)

    Hata, Nobuhiko [University of Tokyo, Graduate School of Information Science and Technology, Tokyo (Japan); Brigham and Women' s Hospital, Department of Radiology, Boston, MA (United States); Wada, Toru [University of Tokyo, Graduate School of Information Science and Technology, Tokyo (Japan); Kashima, Kyoko; Okada, Yoshiyuki [National Center for Child Health and Development, Department of Radiology, Tokyo (Japan); Unno, Nobuya [Nagano Children' s Hospital, Center for Perinatal Medicine, Nagano (Japan); Kitagawa, Michihiro [National Center for Child Health and Development, Department of Prenatal Medicine and Maternal Care, Tokyo (Japan); Chiba, Toshio [National Center for Child Health and Development, Department of Strategic Medicine, Tokyo (Japan)

    2005-08-01

    Currently, the standard method of diagnosis of twin reversed arterial perfusion (TRAP) sequence is ultrasound imaging. The use of MRI for flow visualization may be a useful adjunct to US imaging for assessing the presence of retrograde blood flow in the acardiac fetus and/or umbilical artery. The technical challenge in fetal MRI flow imaging, however, is that fetal electrocardiogram (ECG) monitoring required for flow imaging is currently unavailable in the MRI scanner. A non-gated MRI flow imaging technique that requires no ECG monitoring was developed using the t-test to detect blood flow in 20 slices of phase-contrast MRI images randomly scanned at the same location over multiple cardiac cycles. A feasibility study was performed in a 24-week acardiac twin that showed no umbilical flow sonographically. Non-gated MRI flow images clearly indicated the presence of blood flow in the umbilical artery to the acardiac twin; however, there was no blood flow beyond the abdomen. This study leads us to conjecture that non-gated MRI flow imaging is sensitive in detecting low-range blood flow velocity and can be an adjunct to Doppler US imaging. (orig.)

  6. Non-gated fetal MRI of umbilical blood flow in an acardiac twin

    International Nuclear Information System (INIS)

    Hata, Nobuhiko; Wada, Toru; Kashima, Kyoko; Okada, Yoshiyuki; Unno, Nobuya; Kitagawa, Michihiro; Chiba, Toshio

    2005-01-01

    Currently, the standard method of diagnosis of twin reversed arterial perfusion (TRAP) sequence is ultrasound imaging. The use of MRI for flow visualization may be a useful adjunct to US imaging for assessing the presence of retrograde blood flow in the acardiac fetus and/or umbilical artery. The technical challenge in fetal MRI flow imaging, however, is that fetal electrocardiogram (ECG) monitoring required for flow imaging is currently unavailable in the MRI scanner. A non-gated MRI flow imaging technique that requires no ECG monitoring was developed using the t-test to detect blood flow in 20 slices of phase-contrast MRI images randomly scanned at the same location over multiple cardiac cycles. A feasibility study was performed in a 24-week acardiac twin that showed no umbilical flow sonographically. Non-gated MRI flow images clearly indicated the presence of blood flow in the umbilical artery to the acardiac twin; however, there was no blood flow beyond the abdomen. This study leads us to conjecture that non-gated MRI flow imaging is sensitive in detecting low-range blood flow velocity and can be an adjunct to Doppler US imaging. (orig.)

  7. Tumor disease and associated congenital abnormalities on prenatal MRI.

    Science.gov (United States)

    Nemec, Stefan F; Horcher, Ernst; Kasprian, Gregor; Brugger, Peter C; Bettelheim, Dieter; Amann, Gabriele; Nemec, Ursula; Rotmensch, Siegfried; Rimoin, David L; Graham, John M; Prayer, Daniela

    2012-02-01

    Fetal tumors can have a devastating effect on the fetus, and may occur in association with congenital malformations. In view of the increasing role of fetal magnetic resonance imaging (MRI) as an adjunct to prenatal ultrasonography (US), we sought to demonstrate the visualization of fetal tumors, with regard to congenital abnormalities, on MRI. This retrospective study included 18 fetuses with tumors depicted on fetal MRI after suspicious US findings. An MRI standard protocol was used to diagnose tumors judged as benign or malignant. All organ systems were assessed for tumor-related complications and other congenital malformations. Available US results and histopathology were compared with MRI. There were 13/18 (72.2%) benign and 5/18 (27.8%) malignant tumors diagnosed: a cerebral primitive neuroectodermal tumor in 1/18, head-neck teratomas in 4/18; ventricular rhabdomyomas in 4/18; a cardiac teratoma in 1/18; a hepatoblastoma in 1/18; neuroblastomas in 2/18; a cystic hemorrhagic adrenal hyperplasia in 1/18; a pelvic leiomyoma in 1/18; sacrococcygeal teratomas in 3/18. Tumor-related complications were present in 13/18 (72.2%) cases; other congenital abnormalities in 3/18 (16.7%). MRI diagnosis and histology were concordant in 8/11 (72.7%) cases. In 6/12 (50%) cases, US and MRI diagnoses were concordant, and, in 6/12 (50%) cases, additional MRI findings changed the US diagnosis. Our MRI results demonstrate the visualization of fetal tumors, with frequently encountered tumor-related complications, and other exceptional congenital abnormalities, which may provide important information for perinatal management. Compared to prenatal US, MRI may add important findings in certain cases. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  8. Tumor disease and associated congenital abnormalities on prenatal MRI

    International Nuclear Information System (INIS)

    Nemec, Stefan F.; Horcher, Ernst; Kasprian, Gregor; Brugger, Peter C.; Bettelheim, Dieter; Amann, Gabriele; Nemec, Ursula; Rotmensch, Siegfried; Rimoin, David L.; Graham, John M. Jr.; Prayer, Daniela

    2012-01-01

    Objective: Fetal tumors can have a devastating effect on the fetus, and may occur in association with congenital malformations. In view of the increasing role of fetal magnetic resonance imaging (MRI) as an adjunct to prenatal ultrasonography (US), we sought to demonstrate the visualization of fetal tumors, with regard to congenital abnormalities, on MRI. Materials and methods: This retrospective study included 18 fetuses with tumors depicted on fetal MRI after suspicious US findings. An MRI standard protocol was used to diagnose tumors judged as benign or malignant. All organ systems were assessed for tumor-related complications and other congenital malformations. Available US results and histopathology were compared with MRI. Results: There were 13/18 (72.2%) benign and 5/18 (27.8%) malignant tumors diagnosed: a cerebral primitive neuroectodermal tumor in 1/18, head–neck teratomas in 4/18; ventricular rhabdomyomas in 4/18; a cardiac teratoma in 1/18; a hepatoblastoma in 1/18; neuroblastomas in 2/18; a cystic hemorrhagic adrenal hyperplasia in 1/18; a pelvic leiomyoma in 1/18; sacrococcygeal teratomas in 3/18. Tumor-related complications were present in 13/18 (72.2%) cases; other congenital abnormalities in 3/18 (16.7%). MRI diagnosis and histology were concordant in 8/11 (72.7%) cases. In 6/12 (50%) cases, US and MRI diagnoses were concordant, and, in 6/12 (50%) cases, additional MRI findings changed the US diagnosis. Conclusion: Our MRI results demonstrate the visualization of fetal tumors, with frequently encountered tumor-related complications, and other exceptional congenital abnormalities, which may provide important information for perinatal management. Compared to prenatal US, MRI may add important findings in certain cases.

  9. MRI in psychiatry

    International Nuclear Information System (INIS)

    Mulert, Christoph; Shenton, Martha E.

    2014-01-01

    This is the first comprehensive textbook on the use of MRI in psychiatry covering imaging techniques, brain systems and a review of findings in different psychiatric disorders. The book is divided into three sections, the first of which covers in detail all the major MRI-based methodological approaches available today, including fMRI, EEG-fMRI, DTI, and MR spectroscopy. In addition, the role of MRI in imaging genetics and combined brain stimulation and imaging is carefully explained. The second section provides an overview of the different brain systems that are relevant for psychiatric disorders, including the systems for perception, emotion, cognition, and reward. The final part of the book presents the MRI findings that are obtained in all the major psychiatric disorders using the previously discussed techniques. Numerous carefully chosen images support the informative text, making this an ideal reference work for all practitioners and trainees with an interest in this flourishing field.

  10. MRI in psychiatry

    Energy Technology Data Exchange (ETDEWEB)

    Mulert, Christoph [UKE, Hamburg (Germany). Psychiatry Neuroimaging Branch; Shenton, Martha E. (ed.) [Harvard Medical School, Boston, MA (United States). Dept. of Psychiatry and Radiology

    2014-07-01

    This is the first comprehensive textbook on the use of MRI in psychiatry covering imaging techniques, brain systems and a review of findings in different psychiatric disorders. The book is divided into three sections, the first of which covers in detail all the major MRI-based methodological approaches available today, including fMRI, EEG-fMRI, DTI, and MR spectroscopy. In addition, the role of MRI in imaging genetics and combined brain stimulation and imaging is carefully explained. The second section provides an overview of the different brain systems that are relevant for psychiatric disorders, including the systems for perception, emotion, cognition, and reward. The final part of the book presents the MRI findings that are obtained in all the major psychiatric disorders using the previously discussed techniques. Numerous carefully chosen images support the informative text, making this an ideal reference work for all practitioners and trainees with an interest in this flourishing field.

  11. Cardiac arrest

    Science.gov (United States)

    ... magnesium. These minerals help your heart's electrical system work. Abnormally high or low levels can cause cardiac arrest. Severe physical stress. Anything that causes a severe stress on your ...

  12. Automatic segmentation of left ventricle in cardiac cine MRI images based on deep learning

    Science.gov (United States)

    Zhou, Tian; Icke, Ilknur; Dogdas, Belma; Parimal, Sarayu; Sampath, Smita; Forbes, Joseph; Bagchi, Ansuman; Chin, Chih-Liang; Chen, Antong

    2017-02-01

    In developing treatment of cardiovascular diseases, short axis cine MRI has been used as a standard technique for understanding the global structural and functional characteristics of the heart, e.g. ventricle dimensions, stroke volume and ejection fraction. To conduct an accurate assessment, heart structures need to be segmented from the cine MRI images with high precision, which could be a laborious task when performed manually. Herein a fully automatic framework is proposed for the segmentation of the left ventricle from the slices of short axis cine MRI scans of porcine subjects using a deep learning approach. For training the deep learning models, which generally requires a large set of data, a public database of human cine MRI scans is used. Experiments on the 3150 cine slices of 7 porcine subjects have shown that when comparing the automatic and manual segmentations the mean slice-wise Dice coefficient is about 0.930, the point-to-curve error is 1.07 mm, and the mean slice-wise Hausdorff distance is around 3.70 mm, which demonstrates the accuracy and robustness of the proposed inter-species translational approach.

  13. Exposure to MRI-related magnetic fields and vertigo in MRI workers.

    Science.gov (United States)

    Schaap, Kristel; Portengen, Lützen; Kromhout, Hans

    2016-03-01

    Vertigo has been reported by people working around magnetic resonance imaging (MRI) scanners and was found to increase with increasing strength of scanner magnets. This suggests an association with exposure to static magnetic fields (SMF) and/or motion-induced time-varying magnetic fields (TVMF). This study assessed the association between various metrics of shift-long exposure to SMF and TVMF and self-reported vertigo among MRI workers. We analysed 358 shifts from 234 employees at 14 MRI facilities in the Netherlands. Participants used logbooks to report vertigo experienced during the work day at the MRI facility. In addition, personal exposure to SMF and TVMF was measured during the same shifts, using portable magnetic field dosimeters. Vertigo was reported during 22 shifts by 20 participants and was significantly associated with peak and time-weighted average (TWA) metrics of SMF as well as TVMF exposure. Associations were most evident with full-shift TWA TVMF exposure. The probability of vertigo occurrence during a work shift exceeded 5% at peak exposure levels of 409 mT and 477 mT/s and at full-shift TWA levels of 3 mT and 0.6 mT/s. These results confirm the hypothesis that vertigo is associated with exposure to MRI-related SMF and TVMF. Strong correlations between various metrics of shift-long exposure make it difficult to disentangle the effects of SMF and TVMF exposure, or identify the most relevant exposure metric. On the other hand, this also implies that several metrics of shift-long exposure to SMF and TVMF should perform similarly in epidemiological studies on MRI-related vertigo. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  14. The Visible Heart® project and free-access website 'Atlas of Human Cardiac Anatomy'.

    Science.gov (United States)

    Iaizzo, Paul A

    2016-12-01

    Pre- and post-evaluations of implantable cardiac devices require innovative and critical testing in all phases of the design process. The Visible Heart ® Project was successfully launched in 1997 and 3 years later the Atlas of Human Cardiac Anatomy website was online. The Visible Heart ® methodologies and Atlas website can be used to better understand human cardiac anatomy, disease states and/or to improve cardiac device design throughout the development process. To date, Visible ® Heart methodologies have been used to reanimate 75 human hearts, all considered non-viable for transplantation. The Atlas is a unique free-access website featuring novel images of functional and fixed human cardiac anatomies from >400 human heart specimens. Furthermore, this website includes education tutorials on anatomy, physiology, congenital heart disease and various imaging modalities. For instance, the Device Tutorial provides examples of commonly deployed devices that were present at the time of in vitro reanimation or were subsequently delivered, including: leads, catheters, valves, annuloplasty rings, leadless pacemakers and stents. Another section of the website displays 3D models of vasculature, blood volumes, and/or tissue volumes reconstructed from computed tomography (CT) and magnetic resonance images (MRI) of various heart specimens. A new section allows the user to interact with various heart models. Visible Heart ® methodologies have enabled our laboratory to reanimate 75 human hearts and visualize functional cardiac anatomies and device/tissue interfaces. The website freely shares all images, video clips and CT/MRI DICOM files in honour of the generous gifts received from donors and their families. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For Permissions, please email: journals.permissions@oup.com.

  15. Superconductive MRI system, FLEXARTTM

    International Nuclear Information System (INIS)

    Suzuki, Hirokazu; Nishikawa, Mineki; Goro, Takehiko

    1994-01-01

    Since the establishment of TAMI (Toshiba America MRI Inc.) in 1989, it has been jointly working with Toshiba on developing a new infrastructure for computer and software technologies to be applied to new MRI (magnetic resonance imaging) systems. As a result of these efforts, the first product of a new series of MRI systems has been introduced on the market. Known as FLEXART TM (a newly created word combining FLEXible and ART), this MRI system incorporates a new 32-bit RISC computer and a new controller for pulse sequences and data acquisition. The product concepts of FLEXART TM are high image quality, high patient throughput, and ease of use, all of which are necessary features for an MRI system in the premium mid-field MRI market segment. (author)

  16. Assessment of the coronary venous system in heart failure patients by blood pool agent enhanced whole-heart MRI

    Energy Technology Data Exchange (ETDEWEB)

    Manzke, Robert [University Hospital of Ulm, Department of Internal Medicine II, Ulm (Germany); Philips Research Europe, Clinical Sites Research, Hamburg (Germany); Binner, Ludwig; Bornstedt, Axel; Merkle, Nico; Lutz, Anja; Gradinger, Robert [University Hospital of Ulm, Department of Internal Medicine II, Ulm (Germany); Rasche, Volker [University Hospital of Ulm, Department of Internal Medicine II, Ulm (Germany); Experimental Cardiovascular Imaging, Internal Medicine II, Ulm (Germany)

    2011-04-15

    To investigate the feasibility of MRI for non-invasive assessment of the coronary sinus (CS) and the number and course of its major tributaries in heart failure patients. Fourteen non-ischaemic heart failure patients scheduled for cardiac resynchronisation therapy (CRT) underwent additional whole-heart coronary venography. MRI was performed 1 day before device implantation. The visibility, location and dimensions of the CS and its major tributaries were assessed and the number of potential implantation sites identified. The MRI results were validated by X-ray venography conventionally acquired during the device implantation procedure. The right atrium (RA), CS and mid-cardiac vein (MCV) could be visualised in all patients. 36% of the identified candidate branches were located posterolaterally, 48% laterally and 16% anterolaterally. The average diameter of the CS was quantified as 9.8 mm, the posterior interventricular vein (PIV) 4.6 mm, posterolateral segments 3.3 mm, lateral 2.9 mm and anterolateral 2.9 mm. Concordance with X-ray in terms of number and location of candidate branches was given in most cases. Contrast-enhanced MRI venography appears feasible for non-invasive pre-interventional assessment of the course of the CS and its major tributaries. (orig.)

  17. Assessment of the coronary venous system in heart failure patients by blood pool agent enhanced whole-heart MRI

    International Nuclear Information System (INIS)

    Manzke, Robert; Binner, Ludwig; Bornstedt, Axel; Merkle, Nico; Lutz, Anja; Gradinger, Robert; Rasche, Volker

    2011-01-01

    To investigate the feasibility of MRI for non-invasive assessment of the coronary sinus (CS) and the number and course of its major tributaries in heart failure patients. Fourteen non-ischaemic heart failure patients scheduled for cardiac resynchronisation therapy (CRT) underwent additional whole-heart coronary venography. MRI was performed 1 day before device implantation. The visibility, location and dimensions of the CS and its major tributaries were assessed and the number of potential implantation sites identified. The MRI results were validated by X-ray venography conventionally acquired during the device implantation procedure. The right atrium (RA), CS and mid-cardiac vein (MCV) could be visualised in all patients. 36% of the identified candidate branches were located posterolaterally, 48% laterally and 16% anterolaterally. The average diameter of the CS was quantified as 9.8 mm, the posterior interventricular vein (PIV) 4.6 mm, posterolateral segments 3.3 mm, lateral 2.9 mm and anterolateral 2.9 mm. Concordance with X-ray in terms of number and location of candidate branches was given in most cases. Contrast-enhanced MRI venography appears feasible for non-invasive pre-interventional assessment of the course of the CS and its major tributaries. (orig.)

  18. Does Late Gadolinium Enhancement still have Value? Right Ventricular Internal Mechanical Work, Ea/Emax and Late Gadolinium Enhancement as Prognostic Markers in Patients with Advanced Pulmonary Hypertension via Cardiac MRI.

    Science.gov (United States)

    Abouelnour, Amr Ei; Doyle, Mark; Thompson, Diane V; Yamrozik, June; Williams, Ronald B; Shah, Moneal B; Soma, Siva Kr; Murali, Srinivas; Benza, Raymond L; Biederman, Robert Ww

    2017-01-01

    Investigate the impact of Right Ventricular (RV) Internal Work (IW), ratio of arterial to ventricular end-systolic elastance (E a /E max ), and RV Insertion Point (IP) Late Gadolinium Enhancement (LGE) on outcome in Pulmonary Hypertension (PH) patients. LGE is well known to be present within the RVIPs and Inter Ventricular Septum (IVS) in PH patients, but its prognostic role remains complex and potentially overestimated via 2D qualitative relative to the 3D quantitative measures now available. However, E a /E max , a measure of ventricular-arterial coupling and IW, when added to external cardiac work i.e. the P-V loop area as correlates to the heart's energy demands, might fundamentally improve measures of prognosis as they interrogate physiology beyond just the RV. Cardiac Magnetic Resonance Imaging (CMR) of 124 PH patients (age = 60±13, 85F) referred to a large tertiary PH center, was retrospectively examined for RV volumetric and functional indices and RVIP LGE%. Right Heart Catheterizations (RHC) performed within 1±2 months of the CMR were reviewed. E a /E max was derived as RV End-Systolic Volume (ESV/RVSV). IW was estimated as RVESV ×(RV end-systolic pressure-RV diastolic pressure). Patients were followed from date of CMR for up to 5 years for MACE (death, hospitalized RV failure, initiation of parenteral prostacyclin, sustained ventricular arrhythmia or referral for lung transplantation). MACE was high; 48/124 (39%) patients had MACE by 1.6±1.3 years. Neither RVIP nor IVS LGE using visual assessment or even 3D quantization predicted MACE. The strongest predictor of MACE was RVIW (OR=1.00013, pright-sided human myocardial pathologies.

  19. Study of Nicorandil stress perfusion MRI in diagnosing ischemic heart disease

    International Nuclear Information System (INIS)

    Tateishi, Toshiki; Iwai, Mitsuhiro; Takeda, Soji; Hayashi, Ryuji

    2006-01-01

    The excellent spatial resolution of myocardial stress perfusion magnetic resonance imaging is effective for the diagnosis of ischemic heart disease. When dipyridamole or adenosine triphosphate is used as a pharmacological stress in cardiac MRI, non-magnetic instruments are required for infusion of these drugs in a MRI room. We attempted to use nicorandil as a pharmacological stressor. Nicorandil exhibited KATP channel opening and nitrate effects, and could be infused without any special instruments. Based on the coronary artery stenosis assessed by coronary angiography, according to the criteria of the American Heart Association (AHA), the sensitivity, specificity and diagnostic accuracy of nicorandil perfusion MRI for the detection of coronary artery stenosis was 85%, 57% and 74.3%, respectively. No major side effects were observed, except for mild hypotension (mean 10 mmHg) after infusion of the drug. It was concluded that myocardial perfusion MRI examination using nicorandil could be performed non-invasively and safely for the evaluation of coronary vessel disease in patients. (author)

  20. MRI of the Chest

    Medline Plus

    Full Text Available ... structure of an organ and how it is working. MRI enables the discovery of abnormalities that might be obscured by bone with other imaging methods. The contrast material used in MRI exams is less likely to produce an allergic reaction than the ...

  1. SU-E-P-10: Imaging in the Cardiac Catheterization Lab - Technologies and Clinical Applications

    International Nuclear Information System (INIS)

    Fetterly, K

    2014-01-01

    Purpose: Diagnosis and treatment of cardiovascular disease in the cardiac catheterization laboratory is often aided by a multitude of imaging technologies. The purpose of this work is to highlight the contributions to patient care offered by the various imaging systems used during cardiovascular interventional procedures. Methods: Imaging technologies used in the cardiac catheterization lab were characterized by their fundamental technology and by the clinical applications for which they are used. Whether the modality is external to the patient, intravascular, or intracavity was specified. Specific clinical procedures for which multiple modalities are routinely used will be highlighted. Results: X-ray imaging modalities include fluoroscopy/angiography and angiography CT. Ultrasound imaging is performed with external, trans-esophageal echocardiography (TEE), and intravascular (IVUS) transducers. Intravascular infrared optical coherence tomography (IVOCT) is used to assess vessel endothelium. Relatively large (>0.5 mm) anatomical structures are imaged with x-ray and ultrasound. IVUS and IVOCT provide high resolution images of vessel walls. Cardiac CT and MRI images are used to plan complex cardiovascular interventions. Advanced applications are used to spatially and temporally merge images from different technologies. Diagnosis and treatment of coronary artery disease frequently utilizes angiography and intra-vascular imaging, and treatment of complex structural heart conditions routinely includes use of multiple imaging modalities. Conclusion: There are several imaging modalities which are routinely used in the cardiac catheterization laboratory to diagnose and treat both coronary artery and structural heart disease. Multiple modalities are frequently used to enhance the quality and safety of procedures. The cardiac catheterization laboratory includes many opportunities for medical physicists to contribute substantially toward advancing patient care

  2. Effect of the full implementation of the European Working Time Directive on operative training in adult cardiac surgery.

    Science.gov (United States)

    Mahesh, Balakrishnan; Sharples, Linda; Codispoti, Massimiliano

    2014-01-01

    Surgical specialties rely on practice and apprenticeship to acquire technical skills. In 2009, the final reduction in working hours to 48 per week, in accordance with the European Working Time Directive (EWTD), has also led to an expansion in the number of trainees. We examined the effect of these changes on operative training in a single high-volume [>1500 procedures/year] adult cardiac surgical center. Setting: A single high-volume [>1500 procedures/year] adult cardiac surgical center. Design: Consecutive data were prospectively collected into a database and retrospectively analyzed. Procedures and Main Outcome Measures: Between January 2006 and August 2010, 6688 consecutive adult cardiac surgical procedures were analyzed. The proportion of cases offered for surgical training were compared for 2 non-overlapping consecutive time periods: 4504 procedures were performed before the final implementation of the EWTD (Phase 1: January 2006-December 2008) and 2184 procedures after the final implementation of the EWTD (Phase 2: January 2009-August 2010). Other predictors of training considered in the analysis were grade of trainee, logistic European system for cardiac operative risk evaluation (EuroSCORE), type of surgical procedure, weekend or late procedure, and consultant. Logistic regression analysis was used to determine the predictors of training cases (procedure performed by trainee) and to evaluate the effect of the EWTD on operative surgical training after correcting for confounding factors. Proportion of training cases rose from 34.6% (1558/4504) during Phase 1 to 43.6% (953/2184) in Phase 2 (p hours [153 (3.4) during Phase 1 vs 116 (5.3) during Phase 2, p hours' procedures, and surgery other than coronary artery bypass grafts. Implementation of the final phase of EWTD has not decreased training in a high-volume center. The positive adjustment of trainers' attitudes and efforts to match trainees' needs allow maintenance of adequate training, despite reduction in

  3. Small animal MRI: clinical MRI as an interface to basic biomedical research

    International Nuclear Information System (INIS)

    Pinkernelle, J.G.; Stelter, L.; Hamm, B.; Teichgraeber, U.

    2008-01-01

    The demand for highly resolved small animal MRI for the purpose of biomedical research has increased constantly. Dedicated small animal MRI scanners working at ultra high field strengths from 4.7 to 7.0 T and even above are MRI at its best. However, using high resolution RF coils in clinical scanners up to 3.0 T, small animal MRI can achieve highly resolved images showing excellent tissue contrast. In fact, in abundant experimental studies, clinical MRI is used for small animal imaging. Mostly clinical RF coils in the single-loop design are applied. In addition, custom-built RF coils and even gradient inserts are used in a clinical scanner. For the reduction of moving artifacts, special MRI-compatible animal ECG und respiration devices are available. In conclusion, clinical devices offer broad availability, are less expense in combination with good imaging performance and provide a translational nature of imaging results. (orig.)

  4. Designing a compact MRI motion phantom

    Directory of Open Access Journals (Sweden)

    Schmiedel Max

    2016-09-01

    Full Text Available Even today, dealing with motion artifacts in magnetic resonance imaging (MRI is a challenging task. Image corruption due to spontaneous body motion complicates diagnosis. In this work, an MRI phantom for rigid motion is presented. It is used to generate motion-corrupted data, which can serve for evaluation of blind motion compensation algorithms. In contrast to commercially available MRI motion phantoms, the presented setup works on small animal MRI systems. Furthermore, retrospective gating is performed on the data, which can be used as a reference for novel motion compensation approaches. The motion of the signal source can be reconstructed using motor trigger signals and be utilized as the ground truth for motion estimation. The proposed setup results in motion corrected images. Moreover, the importance of preprocessing the MRI raw data, e.g. phase-drift correction, is demonstrated. The gained knowledge can be used to design an MRI phantom for elastic motion.

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a ...

  6. Infarct-like acute myocarditis: relation between electrocardiographic findings and myocardial damage as assessed by cardiac magnetic resonance imaging.

    Science.gov (United States)

    Nucifora, Gaetano; Miani, Daniela; Di Chiara, Antonio; Piccoli, Gianluca; Artico, Jessica; Puppato, Michela; Slavich, Gianaugusto; De Biasio, Marzia; Gasparini, Daniele; Proclemer, Alessandro

    2013-03-01

    Acute myocarditis (AM) may occasionally have an infarct-like presentation. The aim of the present study was to investigate the relation between electrocardiographic (ECG) findings in this group of patients and myocardial damage assessed by cardiac magnetic resonance imaging (MRI) with the late gadolinium enhancement (LGE) technique. Myocardial damage may be associated with ECG changes in infarct-like AM. Forty-one consecutive patients (36 males; mean age, 36 ± 12 years) with diagnosis of AM according to cardiac MRI Lake Louise criteria and infarct-like presentation were included. The relation between site of ST-segment elevation (STE), sum of STE (sumSTE), time to normalization of STE, and development of negative T wave with the extent of LGE (expressed as % of left ventricular mass [%LV LGE]), was evaluated. Most (80%) patients presented with inferolateral STE; mean sumSTE was 5 ± 3 mm. Normalization of STE occurred within 24 hours in 20 (49%) patients. Development of negative T wave occurred in 28 (68%) patients. Cardiac MRI showed LGE in all patients; mean %LV LGE was 9.6 ± 7.2%. Topographic agreement between site of STE and LGE was 68%. At multivariate analysis, sumSTE (β = 0.42, P 24 hours (β = 0.39, P 24 hours, and development of negative T wave) may help to identify patients with larger areas of myocardial damage. © 2012 Wiley Periodicals, Inc.

  7. TH-B-207B-02: Optimizing Pediatic Cardiovascular MRI

    International Nuclear Information System (INIS)

    Deng, J.

    2016-01-01

    This imaging educational program will focus on solutions to common pediatric image quality optimization challenges. The speakers will present collective knowledge on best practices in pediatric imaging from their experience at dedicated children’s hospitals. One of the most commonly encountered pediatric imaging requirements for the non-specialist hospital is pediatric CT in the emergency room setting. Thus, this educational program will begin with optimization of pediatric CT in the emergency department. Though pediatric cardiovascular MRI may be less common in the non-specialist hospitals, low pediatric volumes and unique cardiovascular anatomy make optimization of these techniques difficult. Therefore, our second speaker will review best practices in pediatric cardiovascular MRI based on experiences from a children’s hospital with a large volume of cardiac patients. Learning Objectives: To learn techniques for optimizing radiation dose and image quality for CT of children in the emergency room setting. To learn solutions for consistently high quality cardiovascular MRI of children

  8. TH-B-207B-02: Optimizing Pediatic Cardiovascular MRI

    Energy Technology Data Exchange (ETDEWEB)

    Deng, J. [Ann & Robert H. Lurie Childrens Hospital, Chicago, IL (United States)

    2016-06-15

    This imaging educational program will focus on solutions to common pediatric image quality optimization challenges. The speakers will present collective knowledge on best practices in pediatric imaging from their experience at dedicated children’s hospitals. One of the most commonly encountered pediatric imaging requirements for the non-specialist hospital is pediatric CT in the emergency room setting. Thus, this educational program will begin with optimization of pediatric CT in the emergency department. Though pediatric cardiovascular MRI may be less common in the non-specialist hospitals, low pediatric volumes and unique cardiovascular anatomy make optimization of these techniques difficult. Therefore, our second speaker will review best practices in pediatric cardiovascular MRI based on experiences from a children’s hospital with a large volume of cardiac patients. Learning Objectives: To learn techniques for optimizing radiation dose and image quality for CT of children in the emergency room setting. To learn solutions for consistently high quality cardiovascular MRI of children.

  9. [Fusion of MRI, fMRI and intraoperative MRI data. Methods and clinical significance exemplified by neurosurgical interventions].

    Science.gov (United States)

    Moche, M; Busse, H; Dannenberg, C; Schulz, T; Schmitgen, A; Trantakis, C; Winkler, D; Schmidt, F; Kahn, T

    2001-11-01

    The aim of this work was to realize and clinically evaluate an image fusion platform for the integration of preoperative MRI and fMRI data into the intraoperative images of an interventional MRI system with a focus on neurosurgical procedures. A vertically open 0.5 T MRI scanner was equipped with a dedicated navigation system enabling the registration of additional imaging modalities (MRI, fMRI, CT) with the intraoperatively acquired data sets. These merged image data served as the basis for interventional planning and multimodal navigation. So far, the system has been used in 70 neurosurgical interventions (13 of which involved image data fusion--requiring 15 minutes extra time). The augmented navigation system is characterized by a higher frame rate and a higher image quality as compared to the system-integrated navigation based on continuously acquired (near) real time images. Patient movement and tissue shifts can be immediately detected by monitoring the morphological differences between both navigation scenes. The multimodal image fusion allowed a refined navigation planning especially for the resection of deeply seated brain lesions or pathologies close to eloquent areas. Augmented intraoperative orientation and instrument guidance improve the safety and accuracy of neurosurgical interventions.

  10. Neural Substrates for Verbal Working Memory in Deaf Signers: fMRI Study and Lesion Case Report

    Science.gov (United States)

    Buchsbaum, Bradley; Pickell, Bert; Love, Tracy; Hatrak, Marla; Bellugi, Ursula; Hickok, Gregory

    2005-01-01

    The nature of the representations maintained in verbal working memory is a topic of debate. Some authors argue for a modality-dependent code, tied to particular sensory or motor systems. Others argue for a modality-neutral code. Sign language affords a unique perspective because it factors out the effects of modality. In an fMRI experiment, deaf…

  11. 3D cardiac wall thickening assessment for acute myocardial infarction

    Science.gov (United States)

    Khalid, A.; Chan, B. T.; Lim, E.; Liew, Y. M.

    2017-06-01

    Acute myocardial infarction (AMI) is the most severe form of coronary artery disease leading to localized myocardial injury and therefore irregularities in the cardiac wall contractility. Studies have found very limited differences in global indices (such as ejection fraction, myocardial mass and volume) between healthy subjects and AMI patients, and therefore suggested regional assessment. Regional index, specifically cardiac wall thickness (WT) and thickening is closely related to cardiac function and could reveal regional abnormality due to AMI. In this study, we developed a 3D wall thickening assessment method to identify regional wall contractility dysfunction due to localized myocardial injury from infarction. Wall thickness and thickening were assessed from 3D personalized cardiac models reconstructed from cine MRI images by fitting inscribed sphere between endocardial and epicardial wall. The thickening analysis was performed in 5 patients and 3 healthy subjects and the results were compared against the gold standard 2D late-gadolinium-enhanced (LGE) images for infarct localization. The notable finding of this study is the highly accurate estimation and visual representation of the infarct size and location in 3D. This study provides clinicians with an intuitive way to visually and qualitatively assess regional cardiac wall dysfunction due to infarction in AMI patients.

  12. Truncus arteriosus communis in a midtrimester fetus: Comparison of prenatal ultrasound and MRI with postmortem MRI and autopsy

    International Nuclear Information System (INIS)

    Muehler, Matthias R.; Lembcke, Alexander; Fischer, Thomas; Kivelitz, Dietmar; Rake, Anett; Chaoui, Rabih; Heling, Kay-Sven; Schwabe, Michael; Planke, Christiane

    2004-01-01

    Different techniques are used in fetal cardiology, and their accuracy has been demonstrated on several occasions. Color Doppler US has proved to be a reliable and valuable tool in the diagnosis of fetal cardiac abnormalities. Magnetic resonance imaging (MRI) of the fetal heart has, so far, played no role in prenatal diagnostics. We report on a truncus arteriosus communis diagnosed prenatally during a screening ultrasound at 22 weeks of gestation. In addition to real-time ultrasound and color Doppler echocardiography, fetal MRI was performed. Fetal echocardiography arose suspicion of a type I common trunk. Fetal MR showed solely a widened vessel coursing retrocardially and additionally an inhomogeneous fluid distribution of the lung not shown on prenatal US. After termination of pregnancy at 23 weeks of gestation, MR fetography and autopsy were performed, and both found a type II common trunk. MR autopsy of the heart was very reliable in this case and could be an alternative when fetal pathology is not available for different reasons. Postmortem MRI was also able to demonstrate the inhomogeneous fluid distribution in the lung, which was confirmed by autopsy. Fetal and postmortem MR was reliable in the detection of an inhomogeneous fluid distribution in the lung not shown on prenatal US, providing a relevant additional finding to US. Therefore, MRI should be used more often in fetal cardiology, although it still must be further developed. (orig.)

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings ... tomography (CT) scans, MRI does not utilize ionizing radiation. Instead, radiofrequency pulses re-align hydrogen atoms that ...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a few types. ...

  15. Role of imaging in evaluation of sudden cardiac death risk in hypertrophic cardiomyopathy.

    Science.gov (United States)

    Geske, Jeffrey B; Ommen, Steve R

    2015-09-01

    Hypertrophic cardiomyopathy (HCM) is the most common heritable cardiomyopathy and is associated with sudden cardiac death (SCD) - an uncommon but devastating clinical outcome. This review is designed to assess the role of imaging in established risk factor assessment and its role in emerging SCD risk stratification. Recent publications have highlighted the crucial role of imaging in HCM SCD risk stratification. Left ventricular hypertrophy assessment remains the key imaging determinant of risk. Data continue to emerge on the role of systolic dysfunction, apical aneurysms, left atrial enlargement and left ventricular outflow tract obstruction as markers of risk. Quantitative assessment of delayed myocardial enhancement and T1 mapping on cardiac MRI continue to evolve. Recent multicenter trials have allowed multivariate SCD risk assessment in large HCM cohorts. Given aggregate risk with presence of multiple risk factors, a single parameter should not be used in isolation to determine implantable cardiac defibrillator candidacy. Use of all available imaging data, including cardiac magnetic resonance tissue characterization, allows a comprehensive approach to SCD stratification and implantable cardiac defibrillator decision-making.

  16. PET/MRI assessment of the infarcted mouse heart

    Energy Technology Data Exchange (ETDEWEB)

    Buonincontri, Guido, E-mail: gb396@cam.ac.uk [Wolfson Brain Imaging Centre, Department of Clinical Neurosciences, University of Cambridge, Cambridge (United Kingdom); Methner, Carmen; Krieg, Thomas [Department of Medicine, University of Cambridge, Cambridge (United Kingdom); Hawkes, Robert C.; Adrian Carpenter, T. [Wolfson Brain Imaging Centre, Department of Clinical Neurosciences, University of Cambridge, Cambridge (United Kingdom); Sawiak, Stephen J., E-mail: sjs80@cam.ac.uk [Wolfson Brain Imaging Centre, Department of Clinical Neurosciences, University of Cambridge, Cambridge (United Kingdom); Behavioural and Clinical Neuroscience Institute, University of Cambridge, Cambridge (United Kingdom)

    2014-01-11

    Heart failure originating from myocardial infarction (MI) is a leading cause of death worldwide. Mouse models of ischaemia and reperfusion injury (I/R) are used to study the effects of novel treatment strategies targeting MI, however staging disease and treatment efficacy is a challenge. Damage and recovery can be assessed on the cellular, tissue or whole-organ scale but these are rarely measured in concert. Here, for the first time, we present data showing measures of injury in infarcted mice using complementary techniques for multi-modal characterisation of the heart. We use in vivo magnetic resonance imaging (MRI) to assess heart function with cine-MRI, hindered perfusion with late gadolinium enhancement imaging and muscular function with displacement encoded with stimulated echoes (DENSE) MRI. These measures are followed by positron emission tomography (PET) with 18-F-fluorodeoxyglucose to assess cellular metabolism. We demonstrate a protocol combining each of these measures for the same animal in the same imaging session and compare how the different markers can be used to quantify cardiac recovery on different scales following injury.

  17. PET/MRI assessment of the infarcted mouse heart

    International Nuclear Information System (INIS)

    Buonincontri, Guido; Methner, Carmen; Krieg, Thomas; Hawkes, Robert C.; Adrian Carpenter, T.; Sawiak, Stephen J.

    2014-01-01

    Heart failure originating from myocardial infarction (MI) is a leading cause of death worldwide. Mouse models of ischaemia and reperfusion injury (I/R) are used to study the effects of novel treatment strategies targeting MI, however staging disease and treatment efficacy is a challenge. Damage and recovery can be assessed on the cellular, tissue or whole-organ scale but these are rarely measured in concert. Here, for the first time, we present data showing measures of injury in infarcted mice using complementary techniques for multi-modal characterisation of the heart. We use in vivo magnetic resonance imaging (MRI) to assess heart function with cine-MRI, hindered perfusion with late gadolinium enhancement imaging and muscular function with displacement encoded with stimulated echoes (DENSE) MRI. These measures are followed by positron emission tomography (PET) with 18-F-fluorodeoxyglucose to assess cellular metabolism. We demonstrate a protocol combining each of these measures for the same animal in the same imaging session and compare how the different markers can be used to quantify cardiac recovery on different scales following injury

  18. A new methodological approach to assess cardiac work by pressure-volume and stress-length relations in patients with aortic valve stenosis and dilated cardiomyopathy.

    Science.gov (United States)

    Alter, P; Rupp, H; Rominger, M B; Klose, K J; Maisch, B

    2008-01-01

    In experimental animals, cardiac work is derived from pressure-volume area and analyzed further using stress-length relations. Lack of methods for determining accurately myocardial mass has until now prevented the use of stress-length relations in patients. We hypothesized, therefore, that not only pressure-volume loops but also stress-length diagrams can be derived from cardiac volume and cardiac mass as assessed by cardiac magnetic resonance imaging (CMR) and invasively measured pressure. Left ventricular (LV) volume and myocardial mass were assessed in seven patients with aortic valve stenosis (AS), eight with dilated cardiomyopathy (DCM), and eight controls using electrocardiogram (ECG)-gated CMR. LV pressure was measured invasively. Pressure-volume curves were calculated based on ECG triggering. Stroke work was assessed as area within the pressure-volume loop. LV wall stress was calculated using a thick-wall sphere model. Similarly, stress-length loops were calculated to quantify stress-length-based work. Taking the LV geometry into account, the normalization with regard to ventricular circumference resulted in "myocardial work." Patients with AS (valve area 0.73+/-0.18 cm(2)) exhibited an increased LV myocardial mass when compared with controls (Pwork of AS was unchanged when compared with controls (0.539+/-0.272 vs 0.621+/-0.138 Nm, not significant), whereas DCM exhibited a significant depression (0.367+/-0.157 Nm, Pwork was significantly reduced in both AS and DCM when compared with controls (129.8+/-69.6, 200.6+/-80.1, 332.2+/-89.6 Nm/m(2), Pmethodological approach of using CMR and invasive pressure measurement. Myocardial work was reduced in patients with DCM and noteworthy also in AS, while stroke work was reduced in DCM only. Most likely, deterioration of myocardial work is crucial for the prognosis. It is suggested to include these basic physiological procedures in the clinical assessment of the pump function of the heart.

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings In most cases, an MRI exam is safe for patients with metal implants, except for a few types. People with the ...

  20. Differentiation between acute and chronic myocardial infarction by means of texture analysis of late gadolinium enhancement and cine cardiac magnetic resonance imaging.

    Science.gov (United States)

    Larroza, Andrés; Materka, Andrzej; López-Lereu, María P; Monmeneu, José V; Bodí, Vicente; Moratal, David

    2017-07-01

    The purpose of this study was to differentiate acute from chronic myocardial infarction using machine learning techniques and texture features extracted from cardiac magnetic resonance imaging (MRI). The study group comprised 22 cases with acute myocardial infarction (AMI) and 22 cases with chronic myocardial infarction (CMI). Cine and late gadolinium enhancement (LGE) MRI were analyzed independently to differentiate AMI from CMI. A total of 279 texture features were extracted from predefined regions of interest (ROIs): the infarcted area on LGE MRI, and the entire myocardium on cine MRI. Classification performance was evaluated by a nested cross-validation approach combining a feature selection technique with three predictive models: random forest, support vector machine (SVM) with Gaussian Kernel, and SVM with polynomial kernel. The polynomial SVM yielded the best classification performance. Receiver operating characteristic curves provided area-under-the-curve (AUC) (mean±standard deviation) of 0.86±0.06 on LGE MRI using 72 features; AMI sensitivity=0.81±0.08 and specificity=0.84±0.09. On cine MRI, AUC=0.82±0.06 using 75 features; AMI sensitivity=0.79±0.10 and specificity=0.80±0.10. We concluded that texture analysis can be used for differentiation of AMI from CMI on cardiac LGE MRI, and also on standard cine sequences in which the infarction is visually imperceptible in most cases. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: Phantom and patient studies

    International Nuclear Information System (INIS)

    Huang, Chuan; Petibon, Yoann; Ouyang, Jinsong; El Fakhri, Georges; Reese, Timothy G.; Ahlman, Mark A.; Bluemke, David A.

    2015-01-01

    Purpose: Degradation of image quality caused by cardiac and respiratory motions hampers the diagnostic quality of cardiac PET. It has been shown that improved diagnostic accuracy of myocardial defect can be achieved by tagged MR (tMR) based PET motion correction using simultaneous PET-MR. However, one major hurdle for the adoption of tMR-based PET motion correction in the PET-MR routine is the long acquisition time needed for the collection of fully sampled tMR data. In this work, the authors propose an accelerated tMR acquisition strategy using parallel imaging and/or compressed sensing and assess the impact on the tMR-based motion corrected PET using phantom and patient data. Methods: Fully sampled tMR data were acquired simultaneously with PET list-mode data on two simultaneous PET-MR scanners for a cardiac phantom and a patient. Parallel imaging and compressed sensing were retrospectively performed by GRAPPA and kt-FOCUSS algorithms with various acceleration factors. Motion fields were estimated using nonrigid B-spline image registration from both the accelerated and fully sampled tMR images. The motion fields were incorporated into a motion corrected ordered subset expectation maximization reconstruction algorithm with motion-dependent attenuation correction. Results: Although tMR acceleration introduced image artifacts into the tMR images for both phantom and patient data, motion corrected PET images yielded similar image quality as those obtained using the fully sampled tMR images for low to moderate acceleration factors (<4). Quantitative analysis of myocardial defect contrast over ten independent noise realizations showed similar results. It was further observed that although the image quality of the motion corrected PET images deteriorates for high acceleration factors, the images were still superior to the images reconstructed without motion correction. Conclusions: Accelerated tMR images obtained with more than 4 times acceleration can still provide

  2. Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: Phantom and patient studies

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Chuan, E-mail: chuan.huang@stonybrookmedicine.edu [Center for Advanced Medical Imaging Sciences, Division of Nuclear Medicine and Molecular Imaging, Department of Imaging, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States); Department of Radiology, Harvard Medical School, Boston, Massachusetts 02115 (United States); Departments of Radiology, Psychiatry, Stony Brook Medicine, Stony Brook, New York 11794 (United States); Petibon, Yoann [Center for Advanced Medical Imaging Sciences, Division of Nuclear Medicine and Molecular Imaging, Department of Imaging, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States); Ouyang, Jinsong; El Fakhri, Georges [Center for Advanced Medical Imaging Sciences, Division of Nuclear Medicine and Molecular Imaging, Department of Imaging, Massachusetts General Hospital, Boston, Massachusetts 02114 and Department of Radiology, Harvard Medical School, Boston, Massachusetts 02115 (United States); Reese, Timothy G. [Department of Radiology, Harvard Medical School, Boston, Massachusetts 02115 and Martinos Center for Biomedical Imaging, Charlestown, Massachusetts 02129 (United States); Ahlman, Mark A.; Bluemke, David A. [Radiology and Imaging Sciences, National Institutes of Health Clinical Center, Bethesda, Maryland 20892 (United States)

    2015-02-15

    Purpose: Degradation of image quality caused by cardiac and respiratory motions hampers the diagnostic quality of cardiac PET. It has been shown that improved diagnostic accuracy of myocardial defect can be achieved by tagged MR (tMR) based PET motion correction using simultaneous PET-MR. However, one major hurdle for the adoption of tMR-based PET motion correction in the PET-MR routine is the long acquisition time needed for the collection of fully sampled tMR data. In this work, the authors propose an accelerated tMR acquisition strategy using parallel imaging and/or compressed sensing and assess the impact on the tMR-based motion corrected PET using phantom and patient data. Methods: Fully sampled tMR data were acquired simultaneously with PET list-mode data on two simultaneous PET-MR scanners for a cardiac phantom and a patient. Parallel imaging and compressed sensing were retrospectively performed by GRAPPA and kt-FOCUSS algorithms with various acceleration factors. Motion fields were estimated using nonrigid B-spline image registration from both the accelerated and fully sampled tMR images. The motion fields were incorporated into a motion corrected ordered subset expectation maximization reconstruction algorithm with motion-dependent attenuation correction. Results: Although tMR acceleration introduced image artifacts into the tMR images for both phantom and patient data, motion corrected PET images yielded similar image quality as those obtained using the fully sampled tMR images for low to moderate acceleration factors (<4). Quantitative analysis of myocardial defect contrast over ten independent noise realizations showed similar results. It was further observed that although the image quality of the motion corrected PET images deteriorates for high acceleration factors, the images were still superior to the images reconstructed without motion correction. Conclusions: Accelerated tMR images obtained with more than 4 times acceleration can still provide

  3. A deadly combination of AIDS, TB and cardiac tumour.

    Science.gov (United States)

    Sahasrabudhe, Tushar Ramesh

    2013-05-22

    Immunocompromised status in AIDS makes differential diagnosis of any symptom very difficult for a clinician. Sharp clinical judgement and plenty of investigations may be needed to reach the diagnosis, as in this case. We hereby present a case of AIDS and active tuberculosis (TB) under treatment. The patient developed acute onset multifocal neurological symptoms following an episode of fever and diarrhoea. The MRI scan revealed numerous large cerebral infarcts. On investigations to evaluate brain infarcts, we made a diagnosis of left atrial cardiac tumour. Association of cardiac tumours with AIDS has only been rarely reported. It is uncertain if these can be opportunistic tumours in AIDS. The patient successfully came out of this deadly combination of diseases, viz AIDS, TB and large brain infarcts due to atrial tumour; with almost complete recovery.

  4. The Cardiac MR Images and Causes of Paradoxical Septal Motion

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Hun [Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of); Choi, Sang Il; Chun, Eun Ju [Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Choi, Sung Hun [Ulsan University Hospital, Ulsan (Korea, Republic of); Park, Jae Hyung [Seoul National University Hospital, Seoul (Korea, Republic of)

    2010-10-15

    Real-time cine MRI studies using the steady-state free precession (SSFP) technique are very useful for evaluating cardiac and septal motion. During diastole, the septum acts as a compliant membrane between the two ventricles, and its position and geometry respond to even small alterations in the trans-septal pressure gradients. Abnormal septal motion can be caused by an overload of the right ventricle, delayed ventricular filling and abnormal conduction. In this study, we illustrate, based on our experiences, the causes of abnormal septal motion such as corrective surgery for tetralogy of Fallot, an atrial septal defect, pulmonary thromboembolism, mitral stenosis, constrictive pericarditis and left bundle branch block. In addition, we discuss the significance of paradoxical septal motion in the context of cardiac MR imaging.

  5. The Cardiac MR Images and Causes of Paradoxical Septal Motion

    International Nuclear Information System (INIS)

    Kim, Dong Hun; Choi, Sang Il; Chun, Eun Ju; Choi, Sung Hun; Park, Jae Hyung

    2010-01-01

    Real-time cine MRI studies using the steady-state free precession (SSFP) technique are very useful for evaluating cardiac and septal motion. During diastole, the septum acts as a compliant membrane between the two ventricles, and its position and geometry respond to even small alterations in the trans-septal pressure gradients. Abnormal septal motion can be caused by an overload of the right ventricle, delayed ventricular filling and abnormal conduction. In this study, we illustrate, based on our experiences, the causes of abnormal septal motion such as corrective surgery for tetralogy of Fallot, an atrial septal defect, pulmonary thromboembolism, mitral stenosis, constrictive pericarditis and left bundle branch block. In addition, we discuss the significance of paradoxical septal motion in the context of cardiac MR imaging

  6. Novel fMRI working memory paradigm accurately detects cognitive impairment in multiple sclerosis.

    Science.gov (United States)

    Nelson, Flavia; Akhtar, Mohammad A; Zúñiga, Edward; Perez, Carlos A; Hasan, Khader M; Wilken, Jeffrey; Wolinsky, Jerry S; Narayana, Ponnada A; Steinberg, Joel L

    2017-05-01

    Cognitive impairment (CI) cannot be diagnosed by magnetic resonance imaging (MRI). Functional magnetic resonance imaging (fMRI) paradigms, such as the immediate/delayed memory task (I/DMT), detect varying degrees of working memory (WM). Preliminary findings using I/DMT showed differences in blood oxygenation level dependent (BOLD) activation between impaired (MSCI, n = 12) and non-impaired (MSNI, n = 9) multiple sclerosis (MS) patients. The aim of the study was to confirm CI detection based on I/DMT BOLD activation in a larger cohort of MS patients. The role of T2 lesion volume (LV) and Expanded Disability Status Scale (EDSS) in magnitude of BOLD signal was also sought. A total of 50 patients (EDSS mean ( m) = 3.2, disease duration (DD) m = 12 years, and age m = 40 years) underwent the Minimal Assessment of Cognitive Function in Multiple Sclerosis (MACFIMS) and I/DMT. Working memory activation (WMa) represents BOLD signal during DMT minus signal during IMT. CI was based on MACFIMS. A total of 10 MSNI, 30 MSCI, and 4 borderline patients were included in the analyses. Analysis of variance (ANOVA) showed MSNI had significantly greater WMa than MSCI, in the left prefrontal cortex and left supplementary motor area ( p = 0.032). Regression analysis showed significant inverse correlations between WMa and T2 LV/EDSS in similar areas ( p = 0.005, 0.004, respectively). I/DMT-based BOLD activation detects CI in MS. Larger studies are needed to confirm these findings.

  7. 4D ultrasound and 3D MRI registration of beating heart

    International Nuclear Information System (INIS)

    Herlambang, N.; Matsumiya, K.; Masamune, K.; Dohi, T.; Liao, H.; Tsukihara, H.; Takamoto, S.

    2007-01-01

    To realize intra-cardiac surgery without cardio-pulmonary bypass, a medical imaging technique with both high image quality and data acquisition rate that is fast enough to follow heart beat movements is required. In this research, we proposed a method that utilized the image quality of MRI and the speed of ultrasound. We developed a 4D image reconstruction method using image registration of 3D MRI and 4D ultrasound images. The registration method consists of rigid registration between 3D MRI and 3D ultrasound with the same heart beat phase, and non-rigid registration between 3D ultrasound images from different heart beat phases. Non-rigid registration was performed with B-spline based registration using variable spring model. In phantom experiment using balloon phantom, registration accuracy was less than 2 mm for total heart volume variation range of 10%. We applied our registration method on 3D MRI and 4D ultrasound images of a volunteer's beating heart data and confirmed through visual observation that heart beat pattern was well reproduced. (orig.)

  8. Pancreatic iron stores assessed by magnetic resonance imaging (MRI) in beta thalassemic patients

    International Nuclear Information System (INIS)

    Feitosa de Assis, Reijâne Alves; Ribeiro, Andreza Alice; Kay, Fernando Uliana; Rosemberg, Laércio Alberto; Nomura, Cesar Higa; Loggetto, Sandra Regina; Araujo, Aderson S.; Fabron Junior, Antonio; Pinheiro de Almeida Veríssimo, Mônica; Baldanzi, Giorgio Roberto; Espósito, Breno Pannia; Baroni, Ronaldo Hueb; Wood, John C.; Hamerschlak, Nelson

    2012-01-01

    Purpose: To assess the correlation between MRI findings of the pancreas with those of the heart and liver in patients with beta thalassemia; to compare the pancreas T2* MRI results with glucose and ferritin levels and labile plasma iron (LPI). Materials and methods: We retrospectively evaluated chronically transfused patients, testing glucose with enzymatic tests, serum ferritin with chemiluminescence, LPI with cellular fluorescence, and T2* MRI to assess iron content in the heart, liver, and pancreas. MRI results were compared with one another and with serum glucose, ferritin, and LPI. Liver iron concentration (LIC) was determined in 11 patients’ liver biopsies by atomic absorption spectrometry. Results: 289 MRI studies were available from 115 patients during the period studied. 9.4% of patients had overt diabetes and an additional 16% of patients had impaired fasting glucose. Both pancreatic and cardiac R2* had predictive power (p 2 = 0.20, p 2 = 0.09, p 2 = 0.14, p 2 = 0.03, p 2 of 0.91. Conclusions: Pancreatic iron overload can be assessed by MRI, but siderosis in other organs did not correlate significantly with pancreatic hemosiderosis.

  9. Impact of thoracic surgery on cardiac morphology and function in small animal models of heart disease: a cardiac MRI study in rats.

    Directory of Open Access Journals (Sweden)

    Peter Nordbeck

    Full Text Available BACKGROUND: Surgical procedures in small animal models of heart disease might evoke alterations in cardiac morphology and function. The aim of this study was to reveal and quantify such potential artificial early or long term effects in vivo, which might account for a significant bias in basic cardiovascular research, and, therefore, could potentially question the meaning of respective studies. METHODS: Female Wistar rats (n = 6 per group were matched for weight and assorted for sham left coronary artery ligation or control. Cardiac morphology and function was then investigated in vivo by cine magnetic resonance imaging at 7 Tesla 1 and 8 weeks after the surgical procedure. The time course of metabolic and inflammatory blood parameters was determined in addition. RESULTS: Compared to healthy controls, rats after sham surgery showed a lower body weight both 1 week (267.5±10.6 vs. 317.0±11.3 g, n<0.05 and 8 weeks (317.0±21.1 vs. 358.7±22.4 g, n<0.05 after the intervention. Left and right ventricular morphology and function were not different in absolute measures in both groups 1 week after surgery. However, there was a confined difference in several cardiac parameters normalized to the body weight (bw, such as myocardial mass (2.19±0.30/0.83±0.13 vs. 1.85±0.22/0.70±0.07 mg left/right per g bw, p<0.05, or enddiastolic ventricular volume (1.31±0.36/1.21±0.31 vs. 1.14±0.20/1.07±0.17 µl left/right per g bw, p<0.05. Vice versa, after 8 weeks, cardiac masses, volumes, and output showed a trend for lower values in sham operated rats compared to controls in absolute measures (782.2±57.2/260.2±33.2 vs. 805.9±84.8/310.4±48.5 mg, p<0.05 for left/right ventricular mass, but not normalized to body weight. Matching these findings, blood testing revealed only minor inflammatory but prolonged metabolic changes after surgery not related to cardiac disease. CONCLUSION: Cardio-thoracic surgical procedures in experimental myocardial infarction

  10. Cholinergic blockade under working memory demands encountered by increased rehearsal strategies: evidence from fMRI in healthy subjects.

    Science.gov (United States)

    Voss, Bianca; Thienel, Renate; Reske, Martina; Kellermann, Thilo; Sheldrick, Abigail J; Halfter, Sarah; Radenbach, Katrin; Shah, Nadim J; Habel, Ute; Kircher, Tilo T J

    2012-06-01

    The connection between cholinergic transmission and cognitive performance has been established in behavioural studies. The specific contribution of the muscarinic receptor system on cognitive performance and brain activation, however, has not been evaluated satisfyingly. To investigate the specific contribution of the muscarinic transmission on neural correlates of working memory, we examined the effects of scopolamine, an antagonist of the muscarinic receptors, using functional magnetic resonance imaging (fMRI). Fifteen healthy male, non-smoking subjects performed a fMRI scanning session following the application of scopolamine (0.4 mg, i.v.) or saline in a placebo-controlled, repeated measure, pseudo-randomized, single-blind design. Working memory was probed using an n-back task. Compared to placebo, challenging the cholinergic transmission with scopolamine resulted in hypoactivations in parietal, occipital and cerebellar areas and hyperactivations in frontal and prefrontal areas. These alterations are interpreted as compensatory strategies used to account for downregulation due to muscarinic acetylcholine blockade in parietal and cerebral storage systems by increased activation in frontal and prefrontal areas related to working memory rehearsal. Our results further underline the importance of cholinergic transmission to working memory performance and determine the specific contribution of muscarinic transmission on cerebral activation associated with executive functioning.

  11. Continuous cardiac troponin I release in Fabry disease.

    Science.gov (United States)

    Feustel, Andreas; Hahn, Andreas; Schneider, Christian; Sieweke, Nicole; Franzen, Wolfgang; Gündüz, Dursun; Rolfs, Arndt; Tanislav, Christian

    2014-01-01

    Fabry disease (FD) is a rare lysosomal storage disorder also affecting the heart. The aims of this study were to determine the frequency of cardiac troponin I (cTNI) elevation, a sensitive parameter reflecting myocardial damage, in a smaller cohort of FD-patients, and to analyze whether persistent cTNI can be a suitable biomarker to assess cardiac dysfunction in FD. cTNI values were determined at least twice per year in 14 FD-patients (6 males and 8 females) regularly followed-up in our centre. The data were related to other parameters of heart function including cardiac magnetic resonance imaging (cMRI). Three patients (21%) without specific vascular risk factors other than FD had persistent cTNI-elevations (range 0.05-0.71 ng/ml, normal: gadolinium enhancement (LGE) in all three individuals with cTNI values ≥0.01, while none of the 11 patients with cTNI <0.01 showed a pathological enhancement (p<0.01). Two subjects with increased cTNI-values underwent coronary angiography, excluding relevant stenoses. A myocardial biopsy performed in one during this procedure demonstrated substantial accumulation of globotriaosylceramide (Gb3) in cardiomyocytes. Continuous cTNI elevation seems to occur in a substantial proportion of patients with FD. The high accordance with LGE, reflecting cardiac dysfunction, suggests that cTNI-elevation can be a useful laboratory parameter for assessing myocardial damage in FD.

  12. PET and MRI: The Odd Couple or a Match Made in Heaven?

    Science.gov (United States)

    Catana, Ciprian; Guimaraes, Alexander R.; Rosen, Bruce R.

    2013-01-01

    Positron emission tomography (PET) and magnetic resonance imaging (MRI) are imaging modalities routinely used for clinical and research applications. Integrated scanners capable of acquiring PET and MRI data in the same imaging session, sequentially or simultaneously, have recently become available for human use. In this manuscript, we describe some of the technical advances that allowed the development of human PET/MR scanners, briefly discuss methodological challenges and opportunities provided by this novel technology and present potential oncologic, cardiac, and neuro-psychiatric applications. These examples range from studies that might immediately benefit from PET/MR to more advanced applications where future development might have an even broader impact. PMID:23492887

  13. MRI assessment of bronchial compression in absent pulmonary valve syndrome and review of the syndrome

    International Nuclear Information System (INIS)

    Taragin, Benjamin H.; Berdon, Walter E.; Prinz, B.

    2006-01-01

    Absent pulmonary valve syndrome (APVS) is a rare cardiac malformation with massive pulmonary insufficiency that presents with short-term and long-term respiratory problems secondary to severe bronchial compression from enlarged central and hilar pulmonary arteries. Association with chromosome 22.Q11 deletions and DiGeorge syndrome is common. This historical review illustrates the airway disease with emphasis on assessment of the bronchial compression in patients with persistent respiratory difficulties post-valvular repair. Cases that had MRI for cardiac assessment are used to illustrate the pattern of airway disease. (orig.)

  14. Delayed-enhancement MRI of apical hypertrophic cardiomyopathy: assessment of the intramural distribution and comparison with clinical symptoms, ventricular arrhythmias, and cine MRI

    International Nuclear Information System (INIS)

    Amano, Yasuo; Fukushima, Yoshimitsu; Kumita, Shinichiro; Takayama, Morimasa; Kitamura, Mitsunobu

    2011-01-01

    Background: Hypertrophic cardiomyopathy (HCM) is reported to show patchy midwall myocardial hyper enhancement on delayed-enhancement magnetic resonance imaging (DE-MRI). The intramural distribution of myocardial hyper enhancement and its correlation with clinical symptoms, ventricular arrhythmias, and cardiac function have not been described for symptomatic apical HCM. Purpose: To evaluate the features and significance of myocardial hyper enhancement on DE-MRI in symptomatic apical HCM. Material and Methods: Thirteen patients with symptomatic apical HCM and their 65 apical segments were investigated. Myocardial hyper enhancement and regional and global functional parameters were determined with MRI. We investigated the intramural distribution and frequencies of this myocardial hyper enhancement and compared them with the patients' clinical symptoms, the presence of ventricular arrhythmias, and cine MRI. Results: Eight (61.5%) patients with symptomatic apical HCM displayed apical myocardial hyper enhancement, and 22 (33.8%) of the 65 apical segments examined showed myocardial hyper enhancement. Of the myocardial hyper enhancement observed, 81.8% showed a subendocardial pattern.The Hyperenhanced apical myocardium had a lower percentage of systolic myocardial thickening, and was associated with serious symptoms (e.g. syncope) and ventricular arrhythmias. Conclusion: Patients with symptomatic apical HCM showed myocardial hyper enhancement involving the subendocardial layer, which might be related to regional systolic dysfunction, serious clinical symptoms, and ventricular arrhythmias

  15. Perception of health risks of electromagnetic fields by MRI radiographers and airport security officers compared to the general Dutch working population: a cross sectional analysis

    Directory of Open Access Journals (Sweden)

    van Dongen Diana

    2011-11-01

    Full Text Available Abstract Background The amount of exposure to electromagnetic fields (EMF at work is mainly determined by an individual's occupation and may differ from exposure at home. It is, however, unknown how different occupational groups perceive possible adverse health effects of EMF. Methods Three occupational groups, the general Dutch working population (n = 567, airport security officers who work with metal detectors (n = 106, and MRI radiographers who work with MRI (n = 193, were compared on perceived risk of and positive and negative feelings towards EMF in general and of different EMF sources, and health concerns by using analyses of variances. Data were collected via an internet survey. Results Overall, MRI radiographers had a lower perceived risk, felt less negative, and more positive towards EMF and different sources of EMF than the general working population and the security officers. For security officers, feeling more positive about EMF was not significantly related to perceived risk of EMF in general or EMF of domestic sources. Feeling positive about a source did not generalize to a lower perceived risk, while negative feelings were stronger related to perceived risk. MRI radiographers had fewer health concerns regarding EMF than the other two groups, although they considered it more likely that EMF could cause physical complaints. Conclusions These data show that although differences in occupation appear to be reflected in different perceptions of EMF, the level of occupational exposure to EMF as such does not predict the perceived health risk of EMF.

  16. Getting an MRI (For Kids)

    Medline Plus

    Full Text Available ... First Aid & Safety Doctors & Hospitals Videos Recipes for Kids Kids site Sitio para niños How the Body Works ... English Español Getting an MRI (Video) KidsHealth / For Kids / Getting an MRI (Video) Print en español Obtención ...

  17. GPU accelerated iterative SENSE reconstruction of radial phase encoded whole-heart MRI

    DEFF Research Database (Denmark)

    Sørensen, Thomas Sangild; Prieto, Claudia; Atkinson, David

    2010-01-01

    Isotropic whole-heart imaging has become an important protocol in simplifying cardiac MRI. The acquisition time can however be a prohibiting factor. To reduce acquisition times a 3D scheme combining Cartesian sampling in the readout direction with radial sampling in the phase encoding plane was r...... time can be brought to a clinically acceptable level using commodity graphics hardware (GPUs)....

  18. Clinical feasibility and validation of 3D principal strain analysis from cine MRI: comparison to 2D strain by MRI and 3D speckle tracking echocardiography.

    Science.gov (United States)

    Satriano, Alessandro; Heydari, Bobak; Narous, Mariam; Exner, Derek V; Mikami, Yoko; Attwood, Monica M; Tyberg, John V; Lydell, Carmen P; Howarth, Andrew G; Fine, Nowell M; White, James A

    2017-12-01

    Two-dimensional (2D) strain analysis is constrained by geometry-dependent reference directions of deformation (i.e. radial, circumferential, and longitudinal) following the assumption of cylindrical chamber architecture. Three-dimensional (3D) principal strain analysis may overcome such limitations by referencing intrinsic (i.e. principal) directions of deformation. This study aimed to demonstrate clinical feasibility of 3D principal strain analysis from routine 2D cine MRI with validation to strain from 2D tagged cine analysis and 3D speckle tracking echocardiography. Thirty-one patients undergoing cardiac MRI were studied. 3D strain was measured from routine, multi-planar 2D cine SSFP images using custom software designed to apply 4D deformation fields to 3D cardiac models to derive principal strain. Comparisons of strain estimates versus those by 2D tagged cine, 2D non-tagged cine (feature tracking), and 3D speckle tracking echocardiography (STE) were performed. Mean age was 51 ± 14 (36% female). Mean LV ejection fraction was 66 ± 10% (range 37-80%). 3D principal strain analysis was feasible in all subjects and showed high inter- and intra-observer reproducibility (ICC range 0.83-0.97 and 0.83-0.98, respectively-p analysis is feasible using routine, multi-planar 2D cine MRI and shows high reproducibility with strong correlations to 2D conventional strain analysis and 3D STE-based analysis. Given its independence from geometry-related directions of deformation this technique may offer unique benefit for the detection and prognostication of myocardial disease, and warrants expanded investigation.

  19. Early myocardial dysfunction in streptozotocin-induced diabetic mice: a study using in vivo magnetic resonance imaging (MRI

    Directory of Open Access Journals (Sweden)

    Chandrasekaran Suresh

    2007-02-01

    Full Text Available Abstract Background Diabetes is associated with a cardiomyopathy that is independent of coronary artery disease or hypertension. In the present study we used in vivo magnetic resonance imaging (MRI and echocardiographic techniques to examine and characterize early changes in myocardial function in a mouse model of type 1 diabetes. Methods Diabetes was induced in 8-week old C57BL/6 mice with two intraperitoneal injections of streptozotocin. The blood glucose levels were maintained at 19–25 mmol/l using intermittent low dosages of long acting insulin glargine. MRI and echocardiography were performed at 4 weeks of diabetes (age of 12 weeks in diabetic mice and age-matched controls. Results After 4 weeks of hyperglycemia one marker of mitochondrial function, NADH oxidase activity, was decreased to 50% of control animals. MRI studies of diabetic mice at 4 weeks demonstrated significant deficits in myocardial morphology and functionality including: a decreased left ventricular (LV wall thickness, an increased LV end-systolic diameter and volume, a diminished LV ejection fraction and cardiac output, a decreased LV circumferential shortening, and decreased LV peak ejection and filling rates. M-mode echocardiographic and Doppler flow studies of diabetic mice at 4 weeks showed a decreased wall thickening and increased E/A ratio, supporting both systolic and diastolic dysfunction. Conclusion Our study demonstrates that MRI interrogation can identify the onset of diabetic cardiomyopathy in mice with its impaired functional capacity and altered morphology. The MRI technique will lend itself to repetitive study of early changes in cardiac function in small animal models of diabetic cardiomyopathy.

  20. Early myocardial dysfunction in streptozotocin-induced diabetic mice: a study using in vivo magnetic resonance imaging (MRI)

    Science.gov (United States)

    Yu, Xichun; Tesiram, Yasvir A; Towner, Rheal A; Abbott, Andrew; Patterson, Eugene; Huang, Shijun; Garrett, Marion W; Chandrasekaran, Suresh; Matsuzaki, Satoshi; Szweda, Luke I; Gordon, Brian E; Kem, David C

    2007-01-01

    Background Diabetes is associated with a cardiomyopathy that is independent of coronary artery disease or hypertension. In the present study we used in vivo magnetic resonance imaging (MRI) and echocardiographic techniques to examine and characterize early changes in myocardial function in a mouse model of type 1 diabetes. Methods Diabetes was induced in 8-week old C57BL/6 mice with two intraperitoneal injections of streptozotocin. The blood glucose levels were maintained at 19–25 mmol/l using intermittent low dosages of long acting insulin glargine. MRI and echocardiography were performed at 4 weeks of diabetes (age of 12 weeks) in diabetic mice and age-matched controls. Results After 4 weeks of hyperglycemia one marker of mitochondrial function, NADH oxidase activity, was decreased to 50% of control animals. MRI studies of diabetic mice at 4 weeks demonstrated significant deficits in myocardial morphology and functionality including: a decreased left ventricular (LV) wall thickness, an increased LV end-systolic diameter and volume, a diminished LV ejection fraction and cardiac output, a decreased LV circumferential shortening, and decreased LV peak ejection and filling rates. M-mode echocardiographic and Doppler flow studies of diabetic mice at 4 weeks showed a decreased wall thickening and increased E/A ratio, supporting both systolic and diastolic dysfunction. Conclusion Our study demonstrates that MRI interrogation can identify the onset of diabetic cardiomyopathy in mice with its impaired functional capacity and altered morphology. The MRI technique will lend itself to repetitive study of early changes in cardiac function in small animal models of diabetic cardiomyopathy. PMID:17309798

  1. Medical Image of the Week: Cardiac Magnetic Resonance Imaging Findings of Severe RV Failure

    Directory of Open Access Journals (Sweden)

    Wickstrom K

    2018-05-01

    Full Text Available No abstract available. Article truncated at 150 words. A 56-year-old man with history a of alcohol abuse presents with progressive shortness of breath on exertion, bilateral lower extremity swelling and 12-pound weight gain over two weeks. His transthoracic echocardiography (Figure 1 demonstrated severely increased global right ventricle (RV size, severely dilated right atrium (RA, severe pulmonary artery (PA dilation, moderate tricuspid regurgitation (TR and right ventricular systolic pressure (RVSP estimated at 85 + central venous pressure (CVP in the context of severely reduced RV systolic function. Right heart catheterization (RHC showed PA pressure (systolic/diastolic, mean of 94/28, 51 mmHg with a PA occlusion pressure of 12 mmHg. After extensive evaluation, our patient’s presentation of right heart failure seemed to be a manifestation of idiopathic pulmonary arterial hypertension. Our patient subsequently had cardiac MRI (cMRI with findings shown above (Figure 2. CMRI is a valuable, three-dimensional imaging modality that provides detailed morphology of the cardiac chambers along with accurate …

  2. Three-dimensional MRI-linac intra-fraction guidance using multiple orthogonal cine-MRI planes

    DEFF Research Database (Denmark)

    Bjerre, Troels; Crijns, Sjoerd; Rosenschöld, Per Munck af

    2013-01-01

    The introduction of integrated MRI-radiation therapy systems will offer live intra-fraction imaging. We propose a feasible low-latency multi-plane MRI-linac guidance strategy. In this work we demonstrate how interleaved acquired, orthogonal cine-MRI planes can be used for low-latency tracking...... of the 3D trajectory of a soft-tissue target structure. The proposed strategy relies on acquiring a pre-treatment 3D breath-hold scan, extracting a 3D target template and performing template matching between this 3D template and pairs of orthogonal 2D cine-MRI planes intersecting the target motion path....... For a 60 s free-breathing series of orthogonal cine-MRI planes, we demonstrate that the method was capable of accurately tracking the respiration related 3D motion of the left kidney. Quantitative evaluation of the method using a dataset designed for this purpose revealed a translational error of 1.15 mm...

  3. Circulating Tumor Cells and Cardiac Metastasis from Esophageal Cancer: A Case Report

    Directory of Open Access Journals (Sweden)

    Francesca Consoli

    2011-05-01

    Full Text Available We report the case of a 67-year-old man affected by metastatic esophageal cancer. The patient developed a symptomatic heart metastasis presenting as mimicking ST-segment elevation myocardial infarction. Cardiac magnetic resonance imaging (MRI documented the presence of a mass in the apex and septum of the left ventriculum. The dissemination of cancer was confirmed by the detection of circulating tumor cells (CTCs in the peripheral blood, measured by the CellSearch System (Veridex, LLC, Raritan, N.J., USA. The blood sample drawn at cardiac disease progression revealed the presence of 2 CTCs per 7.5 ml of blood. This report highlights the potential role of CTCs as markers of metastatic spread.

  4. Superconducting MRI system, MRT-50A

    International Nuclear Information System (INIS)

    Sugimoto, Hiroshi; Asahina, Kiyotaka

    1987-01-01

    The writers' developmental work on MRI (magnetic resonance imaging) was started in 1983. The model used first was MRT-15A (0.15 T). The next model was MRT-22A (0.22 T) which had a magnetic self-shield. As for the development of superconducting MRI system, they started clinical evaluation at Toshiba Central Hospital MRI Center in 1984 and got the official approval in 1985. For the model, use was made of MRT-50A (0.5 T) employing a superconducting magnet made by Toshiba. Herein represented are the basis of the images obtained through MRT-50 and the fact that the application fields of MRI are going on increasing (not only to brain and spine areas but also to the areas of the chest, abdomen and joints), and also the results of the work-in-progress of application software. (author)

  5. Magnetic resonance imaging (MRI) of the cardiovascular system

    International Nuclear Information System (INIS)

    Yoshida, Shigeru

    1991-01-01

    Qualitative assessments of the hypertrophied myocardium were performed using spin-lattice relaxation time (T1) and spin-spin relaxation time (T2) obtained by magnetic resonance imaging (MRI) in 15 normotensive patients with asymmetric septal hypertrophy (ASH), 10 hypertensive patients with concentric hypertrophy (CH) and 5 normal subjects (N). The changes of these values were evaluated related to cardiac cycle, and their usefulness in differentiating diseases. The wall thickness and internal dimension of the left ventricle (LV) in 10 cases were obtained using echocardiography and MRI, and there was a good correlation coefficient in wall thickness (r=0.987) and in internal dimension (r=0.991). Left ventricular short-axis images were obtained using ECG-gated spin-echo sequence (Te=30, 80 msec) and using inversion recovery sequence. T1 and T2 images were calculated at endsystolic and diastolic cardiac phases. The regional wall thickness (WT) and T1 and T2 values were measured in the anterior septum, anterior wall, lateral wall, posterior wall and posterior septum. Myocardial T1 and T2 values were significantly decreased in systole (T1: 185.6±37.9 msec, T2: 24.4±6.3 msec) compared to those in diastole (T1: 249.2±56.7 msec, T2: 31.7±9.4 msec). In both ASH and CH groups, significant correlations were observed between diastolic T1 values and WT (ASH: r=0.80, CH: r=0.45), and between diastolic T2 values and WT (ASH: r=0.58, CH: r=0.60). In the regions where diastolic WT were more than 17 mm, T1 values in the ASH group (343.4±40.5 msec) were significantly higher than those of the CH group (247.3±21.4 msec), although the mean wall thickness values were similar in both groups. These results indicate that myocardial relaxation times are related to cardiac cycle, wall thickness and types of hypertrophy. The T1 and T2 values at diastolic cardiac phase might be useful for distinguishing hypertrophic cardiomyopathy from hypertrophy due to hypertension. (author)

  6. Prognostic value of cardiovascular MRI in diabetics; Prognostischer Wert der kardiovaskulaeren MRT bei Diabetikern

    Energy Technology Data Exchange (ETDEWEB)

    Schlett, C.L.; Bertheau, R.C.; Kauczor, H.U.; Weckbach, S. [Universitaetsklinikum Heidelberg, Klinik fuer Diagnostische und Interventionelle Radiologie, Heidelberg (Germany)

    2015-04-01

    Despite an increased cardiovascular risk in patients with diabetes mellitus they are a heterogeneous population with very different individual manifestation of diseases; therefore, a profound stratification is recommended. Clinical examinations and blood biomarkers are typically used in diabetic patients to determine the risk for developing cardio-cerebrovascular events. Cardiac as well as whole-body magnetic resonance imaging (MRI) including cardiovascular sequences are established methods for clinical diagnostics. Their significance in predicting the outcome and the corresponding risk stratification for patients with diabetes is becoming increasingly more important based on recent study results. Late gadolinium enhancement (LGE) in cardiac MRI detects silent myocardial ischemia in up to 30 % of diabetic patients, which is associated with a hazard ratio of 3-6 for cardiovascular events. Regional left ventricular wall motion abnormalities and decreased ejection fraction also have a prognostic value in diabetics. Based on whole-body MRI, the vessel score as well as carotid artery stenosis have been evaluated as additional predictors for cardio-cerebrovascular events. The MRI-based predictors have independent and incremental prognostic value beyond traditional risk stratification for cardio-cerebrovascular events; however, only the comprehensive assessment of whole-body MRI including angiography allows the identification of patients who remain free of cardio-cerebrovascular events over a period of 6 years. Cardiac MRI, particularly the detection of LGE, can be recommended for risk stratification of patients with diabetes mellitus. The clinical relevance of the added prognostic value of whole-body MRI needs to be clarified in further studies. (orig.) [German] Trotz eines im Durchschnitt erhoehten kardiovaskulaeren Risikos sind Diabetiker eine heterogene Population mit hoechst unterschiedlichen individuellen Krankheitsverlaeufen, sodass eine fundierte

  7. Quantitative assessment of left ventricular function with dual-source CT in comparison to cardiac magnetic resonance imaging: initial findings

    Energy Technology Data Exchange (ETDEWEB)

    Busch, S.; Johnson, T.R.C.; Wintersperger, B.J.; Minaifar, N.; Bhargava, A.; Rist, C.; Reiser, M.F.; Becker, C.; Nikolaou, K. [University of Munich, Department of Clinical Radiology, Munich (Germany)

    2008-03-15

    Cardiac magnetic resonance imaging and echocardiography are currently regarded as standard modalities for the quantification of left ventricular volumes and ejection fraction. With the recent introduction of dual-source computedtomography (DSCT), the increased temporal resolution of 83 ms should also improve the assessment of cardiac function in CT. The aim of this study was to evaluate the accuracy of DSCT in the assessment of left ventricular functional parameters with cardiac magnetic resonance imaging (MRI) as standard of reference. Fifteen patients (two female, 13 male; mean age 50.8 {+-} 19.2 years) underwent CT and MRI examinations on a DSCT (Somatom Definition; Siemens Medical Solutions, Forchheim, Germany) and a 3.0-Tesla MR scanner (Magnetom Trio; Siemens Medical Solutions), respectively. Multiphase axial CT images were analysed with a semiautomatic region growing algorithms (Syngo Circulation; Siemens Medical Solutions) by two independent blinded observers. In MRI, dynamic cine loops of short axis slices were evaluated with semiautomatic contour detection software (ARGUS; Siemens Medical Solutions) independently by two readers. End-systolic volume (ESV), end-diastolic volume (EDV), ejection fraction (EF) and stroke volume (SV) were determined for both modalities, and correlation coefficient, systematic error, limits of agreement and inter-observer variability were assessed. In DSCT, EDV and ESV were 135.8 {+-} 41.9 ml and 54.9 {+-} 29.6 ml, respectively, compared with 132.1 {+-} 40.8 ml EDV and 57.6 {+-} 27.3 ml ESV in MRI. Thus, EDV was overestimated by 3.7 ml (limits of agreement -46.1/+53.6), while ESV was underestimated by 2.6 ml (-36.6/+31.4). Mean EF was 61.6 {+-} 12.4% in DSCT and 57.9 {+-} 9.0% in MRI, resulting in an overestimation of EF by 3.8% with limits of agreement at -14.7 and +22.2%. Rank correlation rho values were 0.81 for EDV (P = 0.0024), 0.79 for ESV (P = 0.0031) and 0.64 for EF (P = 0.0168). The kappa value of inter

  8. Quantitative assessment of left ventricular function with dual-source CT in comparison to cardiac magnetic resonance imaging: initial findings

    International Nuclear Information System (INIS)

    Busch, S.; Johnson, T.R.C.; Wintersperger, B.J.; Minaifar, N.; Bhargava, A.; Rist, C.; Reiser, M.F.; Becker, C.; Nikolaou, K.

    2008-01-01

    Cardiac magnetic resonance imaging and echocardiography are currently regarded as standard modalities for the quantification of left ventricular volumes and ejection fraction. With the recent introduction of dual-source computedtomography (DSCT), the increased temporal resolution of 83 ms should also improve the assessment of cardiac function in CT. The aim of this study was to evaluate the accuracy of DSCT in the assessment of left ventricular functional parameters with cardiac magnetic resonance imaging (MRI) as standard of reference. Fifteen patients (two female, 13 male; mean age 50.8 ± 19.2 years) underwent CT and MRI examinations on a DSCT (Somatom Definition; Siemens Medical Solutions, Forchheim, Germany) and a 3.0-Tesla MR scanner (Magnetom Trio; Siemens Medical Solutions), respectively. Multiphase axial CT images were analysed with a semiautomatic region growing algorithms (Syngo Circulation; Siemens Medical Solutions) by two independent blinded observers. In MRI, dynamic cine loops of short axis slices were evaluated with semiautomatic contour detection software (ARGUS; Siemens Medical Solutions) independently by two readers. End-systolic volume (ESV), end-diastolic volume (EDV), ejection fraction (EF) and stroke volume (SV) were determined for both modalities, and correlation coefficient, systematic error, limits of agreement and inter-observer variability were assessed. In DSCT, EDV and ESV were 135.8 ± 41.9 ml and 54.9 ± 29.6 ml, respectively, compared with 132.1 ± 40.8 ml EDV and 57.6 ± 27.3 ml ESV in MRI. Thus, EDV was overestimated by 3.7 ml (limits of agreement -46.1/+53.6), while ESV was underestimated by 2.6 ml (-36.6/+31.4). Mean EF was 61.6 ± 12.4% in DSCT and 57.9 ± 9.0% in MRI, resulting in an overestimation of EF by 3.8% with limits of agreement at -14.7 and +22.2%. Rank correlation rho values were 0.81 for EDV (P = 0.0024), 0.79 for ESV (P 0.0031) and 0.64 for EF (P = 0.0168). The kappa value of inter-observer variability were

  9. Modality Specific Cerebro-Cerebellar Activations in Verbal Working Memory: An fMRI Study

    Directory of Open Access Journals (Sweden)

    Matthew P. Kirschen

    2010-01-01

    Full Text Available Verbal working memory (VWM engages frontal and temporal/parietal circuits subserving the phonological loop, as well as, superior and inferior cerebellar regions which have projections from these neocortical areas. Different cerebro-cerebellar circuits may be engaged for integrating aurally- and visually-presented information for VWM. The present fMRI study investigated load (2, 4, or 6 letters and modality (auditory and visual dependent cerebro-cerebellar VWM activation using a Sternberg task. FMRI revealed modality-independent activations in left frontal (BA 6/9/44, insular, cingulate (BA 32, and bilateral inferior parietal/supramarginal (BA 40 regions, as well as in bilateral superior (HVI and right inferior (HVIII cerebellar regions. Visual presentation evoked prominent activations in right superior (HVI/CrusI cerebellum, bilateral occipital (BA19 and left parietal (BA7/40 cortex while auditory presentation showed robust activations predominately in bilateral temporal regions (BA21/22. In the cerebellum, we noted a visual to auditory emphasis of function progressing from superior to inferior and from lateral to medial regions. These results extend our previous findings of fMRI activation in cerebro-cerebellar networks during VWM, and demonstrate both modality dependent commonalities and differences in activations with increasing memory load.

  10. Modality Specific Cerebro-Cerebellar Activations in Verbal Working Memory: An fMRI Study

    Science.gov (United States)

    Kirschen, Matthew P.; Chen, S. H. Annabel; Desmond, John E.

    2010-01-01

    Verbal working memory (VWM) engages frontal and temporal/parietal circuits subserving the phonological loop, as well as, superior and inferior cerebellar regions which have projections from these neocortical areas. Different cerebro-cerebellar circuits may be engaged for integrating aurally- and visually-presented information for VWM. The present fMRI study investigated load (2, 4, or 6 letters) and modality (auditory and visual) dependent cerebro-cerebellar VWM activation using a Sternberg task. FMRI revealed modality-independent activations in left frontal (BA 6/9/44), insular, cingulate (BA 32), and bilateral inferior parietal/supramarginal (BA 40) regions, as well as in bilateral superior (HVI) and right inferior (HVIII) cerebellar regions. Visual presentation evoked prominent activations in right superior (HVI/CrusI) cerebellum, bilateral occipital (BA19) and left parietal (BA7/40) cortex while auditory presentation showed robust activations predominately in bilateral temporal regions (BA21/22). In the cerebellum, we noted a visual to auditory emphasis of function progressing from superior to inferior and from lateral to medial regions. These results extend our previous findings of fMRI activation in cerebro-cerebellar networks during VWM, and demonstrate both modality dependent commonalities and differences in activations with increasing memory load. PMID:20714061

  11. Three-dimensional MRI-linac intra-fraction guidance using multiple orthogonal cine-MRI planes.

    Science.gov (United States)

    Bjerre, Troels; Crijns, Sjoerd; af Rosenschöld, Per Munck; Aznar, Marianne; Specht, Lena; Larsen, Rasmus; Keall, Paul

    2013-07-21

    The introduction of integrated MRI-radiation therapy systems will offer live intra-fraction imaging. We propose a feasible low-latency multi-plane MRI-linac guidance strategy. In this work we demonstrate how interleaved acquired, orthogonal cine-MRI planes can be used for low-latency tracking of the 3D trajectory of a soft-tissue target structure. The proposed strategy relies on acquiring a pre-treatment 3D breath-hold scan, extracting a 3D target template and performing template matching between this 3D template and pairs of orthogonal 2D cine-MRI planes intersecting the target motion path. For a 60 s free-breathing series of orthogonal cine-MRI planes, we demonstrate that the method was capable of accurately tracking the respiration related 3D motion of the left kidney. Quantitative evaluation of the method using a dataset designed for this purpose revealed a translational error of 1.15 mm for a translation of 39.9 mm. We have demonstrated how interleaved acquired, orthogonal cine-MRI planes can be used for online tracking of soft-tissue target volumes.

  12. Study of cysticercosis in the fourth ventricle by CSF cinema MRI

    International Nuclear Information System (INIS)

    Wang Lianqing; Liu Lianxiang; Wu Jie; Wu Jing; Zhang Renshu; Wu Yujin

    1997-01-01

    Purpose: To evaluate the diagnostic value of cysticercosis in the fourth ventricle by CSF cinema MRI. Materials and methods: Nine patients with intraventricular cysticercosis in the fourth ventricle were studied. The diagnosis was confirmed by surgery in all cases. All of these patients were examined systematically before the operation and studied with CSF cinema MRI in mid sagittal section and finger-gated scan technique. Results: (1) The path of CSF flow was directly displayed. All cysticercosis presented as a filling defect, and a cyst with a smooth wall. (2) The ventricular compliance was normal in cysticercosis. (3) The cysticercosis in active stage was free in the fourth ventricle and could be rolled over, its shape might change slightly within a cardiac cycle. In the degenerative stage, its wall could adhere to the ependyma and obstruct the CSF flow. Conclusion: CSF cinema MRI can demonstrate the degree of obstruction and pattern of CSF flow in cysticercosis of the fourth ventricle, thereby providing useful information for proper management

  13. Cerebral blood flow and intracranial pulsatility studied with MRI: measurement, physiological and pathophysiological aspects

    International Nuclear Information System (INIS)

    Waahlin, Anders

    2012-01-01

    During each cardiac cycle pulsatile arterial blood inflates the vascular bed of the brain, forcing cerebrospinal fluid (CSF) and venous blood out of the cranium. Excessive arterial pulsatility may be part of a harmful mechanism causing cognitive decline among elderly. Additionally, restricted venous flow from the brain is suggested as the cause of multiple sclerosis. Addressing hypotheses derived from these observations requires accurate and reliable investigational methods. This work focused on assessing the pulsatile waveform of cerebral arterial, venous and CSF flows. The overall aim of this dissertation was to explore cerebral blood flow and intracranial pulsatility using MRI, with respect to measurement, physiological and pathophysiological aspects.Two-dimensional phase contrast magnetic resonance imaging (2D PCMRI) was used to assess the pulsatile waveforms of cerebral arterial, venous and CSF flow. The repeatability was assessed in healthy young subjects. The 2D PCMRI measurements of cerebral arterial, venous and CSF pulsatility were generally repeatable but the pulsatility decreased systematically during the investigation. A method combining 2D PCMRI measurements with invasive CSF infusion tests to determine the magnitude and distribution of compliance within the craniospinal system was developed and applied in a group of healthy elderly. The intracranial space contained approximately two thirds of the total craniospinal compliance. The magnitude of craniospinal compliance was less than suggested in previous studies. The vascular hypothesis for multiple sclerosis was tested. Venous drainage in the internal jugular veins was compared between healthy controls and multiple sclerosis patients using 2D PCMRI. For both groups, a great variability in the internal jugular flow was observed but no pattern specific to multiple sclerosis could be found. Relationships between regional brain volumes and potential biomarkers of intracranial cardiac-related pulsatile

  14. Cerebral blood flow and intracranial pulsatility studied with MRI: measurement, physiological and pathophysiological aspects

    Energy Technology Data Exchange (ETDEWEB)

    Waahlin, Anders

    2012-07-01

    During each cardiac cycle pulsatile arterial blood inflates the vascular bed of the brain, forcing cerebrospinal fluid (CSF) and venous blood out of the cranium. Excessive arterial pulsatility may be part of a harmful mechanism causing cognitive decline among elderly. Additionally, restricted venous flow from the brain is suggested as the cause of multiple sclerosis. Addressing hypotheses derived from these observations requires accurate and reliable investigational methods. This work focused on assessing the pulsatile waveform of cerebral arterial, venous and CSF flows. The overall aim of this dissertation was to explore cerebral blood flow and intracranial pulsatility using MRI, with respect to measurement, physiological and pathophysiological aspects.Two-dimensional phase contrast magnetic resonance imaging (2D PCMRI) was used to assess the pulsatile waveforms of cerebral arterial, venous and CSF flow. The repeatability was assessed in healthy young subjects. The 2D PCMRI measurements of cerebral arterial, venous and CSF pulsatility were generally repeatable but the pulsatility decreased systematically during the investigation. A method combining 2D PCMRI measurements with invasive CSF infusion tests to determine the magnitude and distribution of compliance within the craniospinal system was developed and applied in a group of healthy elderly. The intracranial space contained approximately two thirds of the total craniospinal compliance. The magnitude of craniospinal compliance was less than suggested in previous studies. The vascular hypothesis for multiple sclerosis was tested. Venous drainage in the internal jugular veins was compared between healthy controls and multiple sclerosis patients using 2D PCMRI. For both groups, a great variability in the internal jugular flow was observed but no pattern specific to multiple sclerosis could be found. Relationships between regional brain volumes and potential biomarkers of intracranial cardiac-related pulsatile

  15. Comparative study between MRI and echocardiography in noncompaction of ventricular myocardium

    International Nuclear Information System (INIS)

    Sun Ziyan; Xia Liming; Wang Chengyuan; Rao Jingjing; Shenyu Weihui

    2007-01-01

    Objective: To investigate the MRI and echocardiography manifestations of noncompaction of ventricular myocardium(NVM) and assess the role of MR1 in the diagnosis of NVM by comparing it with echocardiography. Methods: Fourteen cases of NVM diagnosed by echocardiography were examined with MRI, including scanning of black-blood sequences, double inversion recovery fast spin echo (DIBFSE) and triple inversion recovery fast spin echo (TIRFSE), and white blood sequence: fast imaging employ steady state acquisition (FIESTA). Scanning plane includes short axis view, four-chamber view and long axis view. Results: Both MRI and echocardiography displayed involvement of left ventricles in thirteen cases and involvement of double ventricles in one case. Apexes of heart and the intermedius are commonly affected. MRI showed 54 segments and echocardiography showed 53 segments affected, and there is no significant difference between the capability of MRI and echocardiography (P=1,000). The affected myocardium consisted of two layers: subendocardial noncompacted myocardium and epicardial compacted myocardium, and the ratio measurement of N/C by MRI was 3.37±0.89 and it was 3.19±0.82 by echocardiography. Noncompacted myocardium was characterized by prominent and excessive myocardial trabeculations and deep intratrabecular recesses, in which the blood flow was communicated with the ventricle. One case was complicated with ventricular aneurysm, and coronary arteriography was performed with unremarkable findings. One case underwent heart transplantation because of progressive heart failure, Gross findings demonstrated prominent muscular' trabeculations with deep intratrabecular recesses, which coincided well with MRI findings. Conclusion: The MRI manifestation of NVM is characteristic, and MRI with multiple series and planes is helpful in the diagnose of NVM. Compared with echocardiography, MRI could display the pathological cardiac muscle more clearly, because of its high soft

  16. Perception of health risks of electromagnetic fields by MRI radiographers and airport security officers compared to the general Dutch working population: a cross sectional analysis.

    Science.gov (United States)

    van Dongen, Diana; Smid, Tjabe; Timmermans, Daniëlle R M

    2011-11-09

    The amount of exposure to electromagnetic fields (EMF) at work is mainly determined by an individual's occupation and may differ from exposure at home. It is, however, unknown how different occupational groups perceive possible adverse health effects of EMF. Three occupational groups, the general Dutch working population (n = 567), airport security officers who work with metal detectors (n = 106), and MRI radiographers who work with MRI (n = 193), were compared on perceived risk of and positive and negative feelings towards EMF in general and of different EMF sources, and health concerns by using analyses of variances. Data were collected via an internet survey. Overall, MRI radiographers had a lower perceived risk, felt less negative, and more positive towards EMF and different sources of EMF than the general working population and the security officers. For security officers, feeling more positive about EMF was not significantly related to perceived risk of EMF in general or EMF of domestic sources. Feeling positive about a source did not generalize to a lower perceived risk, while negative feelings were stronger related to perceived risk. MRI radiographers had fewer health concerns regarding EMF than the other two groups, although they considered it more likely that EMF could cause physical complaints. These data show that although differences in occupation appear to be reflected in different perceptions of EMF, the level of occupational exposure to EMF as such does not predict the perceived health risk of EMF. © 2011 van Dongen et al; licensee BioMed Central Ltd.

  17. Functional MRI of the patellofemoral joint: comparison of ultrafast MRI, motion-triggered cine MRI and static MRI

    Energy Technology Data Exchange (ETDEWEB)

    Muhle, C. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany); Brossmann, J. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany); Melchert, U.H. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany); Schroeder, C. [Radiologische Abt., Universitaets-Kinderklinik, Christian-Albrechts-Universitaet, Kiel (Germany); Boer, R. de [Philips Medical Systems, Best (Netherlands); Spielmann, R.P. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany); Heller, M. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany)

    1995-12-31

    To evaluate the feasibility and usefulness of ultrafast MRI (u), patellar tracking from 30 of flexion to knee extension (0 ) was analysed and compared with motion-triggered cine MRI (m) and a static MRI technique (s). The different imaging methods were compared in respect of the patellofemoral relationship, the examination time and image quality. Eight healthy subjects and four patients (in total 18 joints) with patellar subluxation or luxation were examined. Significant differences between the static MRI series without quadriceps contraction and the functional MRI studies (motion-triggered cine MRI and ultrafast MRI) were found for the patellar tilt angle. In the dynamic joint studies there was no statistical difference of the regression coefficients between the motion-triggered cine MRI studies and the ultrafast MRI studies. The findings of the functional MRI studies compared with the static MRI images were significantly different for the lateralisation of the patella, expressed by the lateral patellar displacement and bisect offset. No significant differences in patellar lateralisation were found between motion-triggered cine MRI and ultrafast MRI. Ultrafast MRI was superior to motion-triggered cine MRI in terms of the reduction in imaging time and improvement of the image quality. (orig.)

  18. Functional MRI of the patellofemoral joint: comparison of ultrafast MRI, motion-triggered cine MRI and static MRI

    International Nuclear Information System (INIS)

    Muhle, C.; Brossmann, J.; Melchert, U.H.; Schroeder, C.; Boer, R. de; Spielmann, R.P.; Heller, M.

    1995-01-01

    To evaluate the feasibility and usefulness of ultrafast MRI (u), patellar tracking from 30 of flexion to knee extension (0 ) was analysed and compared with motion-triggered cine MRI (m) and a static MRI technique (s). The different imaging methods were compared in respect of the patellofemoral relationship, the examination time and image quality. Eight healthy subjects and four patients (in total 18 joints) with patellar subluxation or luxation were examined. Significant differences between the static MRI series without quadriceps contraction and the functional MRI studies (motion-triggered cine MRI and ultrafast MRI) were found for the patellar tilt angle. In the dynamic joint studies there was no statistical difference of the regression coefficients between the motion-triggered cine MRI studies and the ultrafast MRI studies. The findings of the functional MRI studies compared with the static MRI images were significantly different for the lateralisation of the patella, expressed by the lateral patellar displacement and bisect offset. No significant differences in patellar lateralisation were found between motion-triggered cine MRI and ultrafast MRI. Ultrafast MRI was superior to motion-triggered cine MRI in terms of the reduction in imaging time and improvement of the image quality. (orig.)

  19. Cardiac cone-beam CT

    International Nuclear Information System (INIS)

    Manzke, Robert

    2005-01-01

    This doctoral thesis addresses imaging of the heart with retrospectively gated helical cone-beam computed tomography (CT). A thorough review of the CT reconstruction literature is presented in combination with a historic overview of cardiac CT imaging and a brief introduction to other cardiac imaging modalities. The thesis includes a comprehensive chapter about the theory of CT reconstruction, familiarizing the reader with the problem of cone-beam reconstruction. The anatomic and dynamic properties of the heart are outlined and techniques to derive the gating information are reviewed. With the extended cardiac reconstruction (ECR) framework, a new approach is presented for the heart-rate-adaptive gated helical cardiac cone-beam CT reconstruction. Reconstruction assessment criteria such as the temporal resolution, the homogeneity in terms of the cardiac phase, and the smoothness at cycle-to-cycle transitions are developed. Several reconstruction optimization approaches are described: An approach for the heart-rate-adaptive optimization of the temporal resolution is presented. Streak artifacts at cycle-to-cycle transitions can be minimized by using an improved cardiac weighting scheme. The optimal quiescent cardiac phase for the reconstruction can be determined automatically with the motion map technique. Results for all optimization procedures applied to ECR are presented and discussed based on patient and phantom data. The ECR algorithm is analyzed for larger detector arrays of future cone-beam systems throughout an extensive simulation study based on a four-dimensional cardiac CT phantom. The results of the scientific work are summarized and an outlook proposing future directions is given. The presented thesis is available for public download at www.cardiac-ct.net

  20. Feasibility of free-breathing, GRAPPA-based, real-time cardiac cine assessment of left-ventricular function in cardiovascular patients at 3 T

    International Nuclear Information System (INIS)

    Zhu, Xiaomei; Schwab, Felix; Marcus, Roy; Hetterich, Holger; Theisen, Daniel; Kramer, Harald; Notohamiprodjo, Mike; Schlett, Christopher L.; Nikolaou, Konstantin; Reiser, Maximilian F.

    2015-01-01

    Highlights: • Grappa-based real time cine cardiac MRI is feasible for assessment of left ventricular function. • Significant underestimation of systolic function, peak ejection and filling rates needs to be considered. • Heart rate is the only positive predictor of the deviation of obtained parameters. - Abstract: Objectives: To determine the feasibility of free-breathing, GRAPPA-based, real-time (RT) cine 3 T cardiac magnetic resonance imaging (MRI) with high acceleration factors for the assessment of left-ventricular function in a cohort of patients as compared to conventional segmented cine imaging. Materials and methods: In this prospective cohort study, subjects with various cardiac conditions underwent MRI involving two RT cine sequences (high resolution and low resolution) and standard segmented cine imaging. Standard qualitative and quantitative parameters of left-ventricular function were quantified. Results: Among 25 subjects, 24 were included in the analysis (mean age: 50.5 ± 21 years, 67% male, 25% with cardiomyopathy). RT cine derived quantitative parameters of volumes and left ventricular mass were strongly correlated with segmented cine imaging (intraclass correlation coefficient [ICC]: >0.72 for both RT cines) but correlation for peak ejection and filling rates were moderate to poor for both RT cines (ICC < 0.40). Similarly, RT cines significantly underestimated peak ejection and filling rates (>103.2 ± 178 ml/s). Among patient-related factors, heart rate was strongly predictive for deviation of measurements (p < 0.05). Conclusions: RT cine MRI at 3 T is feasible for qualitative and quantitative assessment of left ventricular function for low and high-resolution sequences but results in significant underestimation of systolic function, peak ejection and filling rates

  1. Inventory of MRI applications and workers exposed to MRI-related electromagnetic fields in the Netherlands.

    Science.gov (United States)

    Schaap, Kristel; Christopher-De Vries, Yvette; Slottje, Pauline; Kromhout, Hans

    2013-12-01

    This study aims to characterise and quantify the population that is occupationally exposed to electromagnetic fields (EMF) from magnetic resonance imaging (MRI) devices and to identify factors that determine the probability and type of exposure. A questionnaire survey was used to collect information about scanners, procedures, historical developments and employees working with or near MRI scanners in clinical and research MRI departments in the Netherlands. Data were obtained from 145 MRI departments. A rapid increase in the use of MRI and field strength of the scanners was observed and quantified. The strongest magnets were employed by academic hospitals and research departments. Approximately 7000 individuals were reported to be working inside an MRI scanner room and were thus considered to have high probability of occupational exposure to static magnetic fields (SMF). Fifty-four per cent was exposed to SMF at least one day per month. The largest occupationally exposed group were radiographers (n ~ 1700). Nine per cent of the 7000 involved workers were regularly present inside a scanner room during image acquisition, when exposure to additional types of EMF is considered a possibility. This practice was most prevalent among workers involved in scanning animals. The data illustrate recent trends and historical developments in magnetic resonance imaging and provide an extensive characterisation of the occupationally exposed population. A considerable number of workers are potentially exposed to MRI-related EMF. Type and frequency of potential exposure depend on the job performed, as well as the type of workplace. Copyright © 2013 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  2. Inventory of MRI applications and workers exposed to MRI-related electromagnetic fields in the Netherlands

    Energy Technology Data Exchange (ETDEWEB)

    Schaap, Kristel; Christopher-De Vries, Yvette; Slottje, Pauline; Kromhout, Hans, E-mail: h.kromhout@uu.nl

    2013-12-01

    Objective: This study aims to characterise and quantify the population that is occupationally exposed to electromagnetic fields (EMF) from magnetic resonance imaging (MRI) devices and to identify factors that determine the probability and type of exposure. Materials and methods: A questionnaire survey was used to collect information about scanners, procedures, historical developments and employees working with or near MRI scanners in clinical and research MRI departments in the Netherlands. Results: Data were obtained from 145 MRI departments. A rapid increase in the use of MRI and field strength of the scanners was observed and quantified. The strongest magnets were employed by academic hospitals and research departments. Approximately 7000 individuals were reported to be working inside an MRI scanner room and were thus considered to have high probability of occupational exposure to static magnetic fields (SMF). Fifty-four per cent was exposed to SMF at least one day per month. The largest occupationally exposed group were radiographers (n ∼ 1700). Nine per cent of the 7000 involved workers were regularly present inside a scanner room during image acquisition, when exposure to additional types of EMF is considered a possibility. This practice was most prevalent among workers involved in scanning animals. Conclusion: The data illustrate recent trends and historical developments in magnetic resonance imaging and provide an extensive characterisation of the occupationally exposed population. A considerable number of workers are potentially exposed to MRI-related EMF. Type and frequency of potential exposure depend on the job performed, as well as the type of workplace.

  3. Coronary artery stent mimicking intracardiac thrombus on cardiac magnetic resonance imaging due to signal loss

    DEFF Research Database (Denmark)

    Qayyum, Abbas Ali; Vejlstrup, Niels Grove; Ahtarovski, Kiril Aleksov

    2012-01-01

    Since the introduction of percutaneous coronary intervention for coronary artery disease, thousands of patients have been treated with the implantation of coronary stents. Moreover, several of the patients with coronary stent undergo cardiac magnetic resonance (CMR) imaging every year. This case...... report is of a 77-year-old man who was previously treated with the implantation of a coronary stent in the left circumflex artery. He underwent CMR imaging, which revealed a process 14×21 mm in the left atrium. Cardiac contrast computed tomography did not demonstrate any cardiac pathology. While...... the signal loss on MRI associated with implanted metallic devices is known, we report a case where an implanted coronary stent in the left circumflex artery led to an intracardiac signal loss mimicking intracardiac thrombus/tumor....

  4. Functional MRI Study of Working Memory Impairment in Patients with Symptomatic Carotid Artery Disease

    Directory of Open Access Journals (Sweden)

    Shasha Zheng

    2014-01-01

    Full Text Available The neuropsychological tests in patients with internal carotid artery (ICA demonstrated cognitive deficits associated with frontal lobe dysfunction, but the pathophysiological mechanism of memory impairment is not fully understood. This study evaluated relationship between degree of ICA stenosis and frontal activations induced by working memory (WM task using fMRI. The fMRI data of 21 patients with unilateral ICA stenosis (left/right, 11/10 and 21 controls were analyzed. In comparison with controls, ICA patients demonstrated significant activations in middle frontal gyrus (MFG bilaterally, particularly in left MFG. In right ICA stenosis, there was slightly less MFG activation than that of controls. Importantly, lower MFG activity was associated with higher stenosis of ipsilateral ICA. For left ICA stenosis, weaker activation in left MFG was negatively correlated with degree of stenosis. Similarly, for right ICA stenosis, there was a significant negative correlation between right ICA stenosis and weaker activation of right MFG. Cognitive impairments in ICA stenosis were associated with frontal lobe dysfunctions. Left ICA stenosis had worse WM impairments than right ICA stenosis, which was affected by the degree of stenosis.

  5. Exploring Possible Neural Mechanisms of Intelligence Differences Using Processing Speed and Working Memory Tasks: An fMRI Study

    Science.gov (United States)

    Waiter, Gordon D.; Deary, Ian J.; Staff, Roger T.; Murray, Alison D.; Fox, Helen C.; Starr, John M.; Whalley, Lawrence J.

    2009-01-01

    To explore the possible neural foundations of individual differences in intelligence test scores, we examined the associations between Raven's Matrices scores and two tasks that were administered in a functional magnetic resonance imaging (fMRI) setting. The two tasks were an n-back working memory (N = 37) task and inspection time (N = 47). The…

  6. The long-term effects of prenatal nicotine exposure on verbal working memory: an fMRI study of young adults.

    Science.gov (United States)

    A Longo, Carmelinda; A Fried, Peter; Cameron, Ian; M Smith, Andra

    2014-11-01

    Using functional magnetic resonance imaging (fMRI), the long-term effects of prenatal nicotine exposure on verbal working memory were investigated in young adults. Participants were members of the Ottawa Prenatal Prospective Study, a longitudinal study that collected a unique body of information on participants from infancy to young adulthood. This allowed for the measurement of an unprecedented number of potentially confounding drug exposure variables including: prenatal marijuana and alcohol exposure and current marijuana, nicotine and alcohol use. Twelve young adults with prenatal nicotine exposure and 13 non-exposed controls performed a 2-Back working memory task while fMRI blood oxygen level-dependent responses were examined. Despite similar task performance, participants with more prenatal nicotine exposure demonstrated significantly greater activity in several regions of the brain that typically subserve verbal working memory including the middle frontal gyrus, precentral gyrus, the inferior parietal lobe and the cingulate gyrus. These results suggest that prenatal nicotine exposure contributes to altered neural functioning during verbal working memory that continues into adulthood. Working memory is critical for a wide range of cognitive skills such as language comprehension, learning and reasoning. Thus, these findings highlight the need for continued educational programs and public awareness campaigns to reduce tobacco use among pregnant women. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  7. Measurement of left atrial volume by 2D and 3D non-contrast computed tomography compared with cardiac magnetic resonance imaging

    DEFF Research Database (Denmark)

    Fredgart, Maise Høigaard; Carter-Storch, Rasmus; Møller, Jacob Eifer

    2018-01-01

    Background: Cardiac magnetic resonance imaging (MRI) is considered the gold standard for assessment of left atrial (LA) volume. We assessed the feasibility of evaluating LA volume using 3D non-contrast computed tomography (NCCT). Furthermore, since manual tracing of LA volume is time consuming, we...... evaluated the accuracy of the LA area using 2D NCCT imaging for LA volume assessment. Methods: MRI and NCCT imaging were performed in 69 patients before and one year after aortic valve replacement. In 3D MRI and 3D NCCT, each slice was manually traced, excluding the pulmonary veins and atrial appendage...

  8. Localized Fluctuant Oscillatory Activity by Working Memory Load: A Simultaneous EEG-fMRI Study

    Directory of Open Access Journals (Sweden)

    Xiaojie Zhao

    2017-10-01

    Full Text Available Working memory (WM is a resource-limited memory system for temporary storage and processing of brain information during the execution of cognitive tasks. Increased WM load will increase the amount and difficulty of memory information. Several studies have used electroencephalography (EEG or functional magnetic resonance imaging (fMRI to explore load-dependent cognition processing according to the time courses of electrophysiological activity or the spatial pattern of blood oxygen metabolic activity. However, the relationships between these two activities and the underlying neural mechanism are still unclear. In this study, using simultaneously collected EEG and fMRI data under an n-back verbal WM task, we modeled the spectral perturbation of EEG oscillation and fMRI activation through joint independent component analysis (JICA. Multi-channel oscillation features were also introduced into the JICA model for further analysis. The results showed that time-locked activity of theta and beta were modulated by memory load in the early stimuli evaluation stage, corresponding to the enhanced activation in the frontal and parietal lobe, which were involved in stimulus discrimination, information encoding and delay-period activity. In the late response selection stage, alpha and gamma activity changes dependent on the load correspond to enhanced activation in the areas of frontal, temporal and parietal lobes, which played important roles in attention, information extraction and memory retention. These findings suggest that the increases in memory load not only affect the intensity and time course of the EEG activities, but also lead to the enhanced activation of brain regions which plays different roles during different time periods of cognitive process of WM.

  9. Localized Fluctuant Oscillatory Activity by Working Memory Load: A Simultaneous EEG-fMRI Study.

    Science.gov (United States)

    Zhao, Xiaojie; Li, Xiaoyun; Yao, Li

    2017-01-01

    Working memory (WM) is a resource-limited memory system for temporary storage and processing of brain information during the execution of cognitive tasks. Increased WM load will increase the amount and difficulty of memory information. Several studies have used electroencephalography (EEG) or functional magnetic resonance imaging (fMRI) to explore load-dependent cognition processing according to the time courses of electrophysiological activity or the spatial pattern of blood oxygen metabolic activity. However, the relationships between these two activities and the underlying neural mechanism are still unclear. In this study, using simultaneously collected EEG and fMRI data under an n-back verbal WM task, we modeled the spectral perturbation of EEG oscillation and fMRI activation through joint independent component analysis (JICA). Multi-channel oscillation features were also introduced into the JICA model for further analysis. The results showed that time-locked activity of theta and beta were modulated by memory load in the early stimuli evaluation stage, corresponding to the enhanced activation in the frontal and parietal lobe, which were involved in stimulus discrimination, information encoding and delay-period activity. In the late response selection stage, alpha and gamma activity changes dependent on the load correspond to enhanced activation in the areas of frontal, temporal and parietal lobes, which played important roles in attention, information extraction and memory retention. These findings suggest that the increases in memory load not only affect the intensity and time course of the EEG activities, but also lead to the enhanced activation of brain regions which plays different roles during different time periods of cognitive process of WM.

  10. [Safety of cardiac pacemakers and implantable cardioverter-defibrillators in magnetic resonance imaging. Assessment of the aggregate function at 1.5 tesla].

    Science.gov (United States)

    Nordbeck, P; Bauer, W R

    2008-03-01

    Magnetic resonance imaging (MRI) is increasingly used in patients, but it is contraindicated in those with cardiac pacemakers (CP) or implantable cardioverter defibrillators (ICD). This study examined circumstances in which potentially life-threatening arrhythmias may be triggered in patients with CP undergoing MRI and whether these problems can be avoided by reprogramming of these devices. Eight CP and seven ICDs were investigated in a phantom at 1.5 tesla (experimental and imaging sequences). A decrease in battery voltage was found in four CP after MRI (indication for elective replacement). Additionally, three showed changes in programming (resets). Analogous changes did not appear in the tested ICDs, but periods of tachycardia were recorded in all types of devices during MRI depending on the pulse sequence employed. MRI-related electromagnetic fields as used in routine MRI can induce severe pacemaker device malfunctions. Device programming approaches are unreliable for prevention of patient hazards, as programming changes or resets are one of the primary malfunctions during MRI.

  11. Low pre-existing gray matter volume in the medial temporal lobe and white matter lesions are associated with postoperative cognitive dysfunction after cardiac surgery.

    Directory of Open Access Journals (Sweden)

    Kengo Maekawa

    Full Text Available OBJECTIVES: Postoperative cognitive dysfunction (POCD is recognized as a complication in the elderly after cardiac surgery. Imaging of the brain provides evidence of neurodegeneration in elderly patients; however, abnormalities in brain structure and their relation to POCD are uncertain. This pilot study investigated whether loss of gray matter in the bilateral medial temporal lobe (MTL, seen in preoperative MRI, was associated with POCD. METHODS: Data were collected prospectively on 28 elderly patients scheduled for elective cardiac surgery. MRI of the brains of all patients were assessed for prior cerebral infarctions, and carotid and intracranial arterial stenosis. Patients also completed six neuropsychological tests of memory, attention and executive function before and after surgery. POCD was defined as an individual decrease in more than two tests of at least 1 standard deviation from the group baseline mean for that test. The degree of gray matter loss in the MTL of each patient was calculated using voxel-based morphometry with three-dimensional, T1-weighted MRI. This represented the degree of gray matter change as a Z score. RESULTS: Postoperative cognitive dysfunction was identified in 8 of the 28 patients (29%. Patients with POCD had significantly more white matter lesions on MRI, and greater loss of gray matter in the bilateral MTL (average Z score 2.0±0.9 than patients without POCD. An analysis by stepwise logistic regression identified gray matter loss in the MTL and cerebral infarctions on MRI as independent predictors of POCD. CONCLUSIONS: These preliminary findings suggested that reduced gray matter in the bilateral MTL and white matter lesions existed in brains of elderly cardiac surgery patients who experienced POCD. Additional studies with larger sample sizes are needed to confirm these findings.

  12. Imaging features of cardiac myxoma

    International Nuclear Information System (INIS)

    Yang Youyou; Zheng Lili; Li Xiangmin; Zhou Xuhui; Kuang Jianyi; Zhang Wenzhao

    2007-01-01

    Objective: To study the imaging features of cardiac myxoma and their diagnostic values. Methods: Twenty-two patrents with cardiac myxoma were reviewed retrospectively for the clinical, pathologic, and radiologic findings. Posteroanterior and lateral chest radiographs, American Imatron C-150 XP Electron Beam CT examination, and Germany Siemens 1.5T Magnetom Vision MR scan were performed on every patient. Results: (1) Radiographs of 17 patients with left atrial myxoma showed evidence of mitral valve obstruction in 14(82.3%), radiographs of 5 patients with right atrial myxoma demonstrated right atrium enlargement in 3(60%) respectively. (2) CT scans of 22 myxomas demonstrated 18 (81.8%) lesions were hypoattenuated and 4 (19.1%) were isoattenuated relative to the myocardium. Calcification or ossification was seen in 3 patients. All myxomas apart from massive one were found attaching to the atrial septum. Movie mode could dis- play the movement of myxoma across the atrioventicular valves. (3) MRI studies of 22 myxomas showed 19 (86.3%) heterogeneous signal intensity and 3 (13.7%) homogeneous. They exhibited slight high or homogeneous signal intensity with both T 1 - and T 2 -weighted sequences, and low signal intensity with cine gradient recalled echo sequences. Point of attachment was visible in 21 (95.4%) cases. Conclusion: The typical radiograph sign of cardiac myxomas is mitral valve obstruction, CT and MR can demonstrate intracavitary lobular masses attacthing to artrial spetum. The latter two kinds of examinations not only provide accurate assessment of the size, location, and attachment point of these lesions, but also have important qualitative diagnostic advantage. (authors)

  13. Work-related outcome after acute coronary syndrome: Implications of complex cardiac rehabilitation in occupational medicine.

    Science.gov (United States)

    Lamberti, Monica; Ratti, Gennaro; Gerardi, Donato; Capogrosso, Cristina; Ricciardi, Gianfranco; Fulgione, Cosimo; Latte, Salvatore; Tammaro, Paolo; Covino, Gregorio; Nienhaus, Albert; Grazillo, Elpidio Maria; Mallardo, Mario; Capogrosso, Paolo

    2016-01-01

    Coronary heart disease is frequent in the working-age population. Traditional outcomes, such as mortality and hospital readmission, are useful for evaluating prognosis. Fit-for-work is an emerging outcome with clinical as well as socioeconomic significance. We describe the possible benefit of a cardiac rehabilitation (CR) program for return to work (RTW) after acute coronary syndrome (ACS). We evaluated 204 patients with recent ACS. They were divided into 4 groups on the basis of their occupational work load: very light (VL), light (L), moderate (M), and heavy (H). Work-related outcomes were assessed with the Work Performance Scale (WPS) of the Functional Status Questionnaire and as "days missed from work" (DMW) in the previous 4 weeks. The variables considered for outcomes were percent ejection fraction, functional capacity expressed in metabolic equivalents (METs), and participation or non-participation in the CR program (CR+ and CR-). One hundred thirty (66%) patients took part in the CR program. Total WPS scores for CR+ and CR- subgroups were VL group: 18±4 vs. 14±4 (p workplace, in particular among clerical workers. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  14. Studying neuroanatomy using MRI.

    Science.gov (United States)

    Lerch, Jason P; van der Kouwe, André J W; Raznahan, Armin; Paus, Tomáš; Johansen-Berg, Heidi; Miller, Karla L; Smith, Stephen M; Fischl, Bruce; Sotiropoulos, Stamatios N

    2017-02-23

    The study of neuroanatomy using imaging enables key insights into how our brains function, are shaped by genes and environment, and change with development, aging and disease. Developments in MRI acquisition, image processing and data modeling have been key to these advances. However, MRI provides an indirect measurement of the biological signals we aim to investigate. Thus, artifacts and key questions of correct interpretation can confound the readouts provided by anatomical MRI. In this review we provide an overview of the methods for measuring macro- and mesoscopic structure and for inferring microstructural properties; we also describe key artifacts and confounds that can lead to incorrect conclusions. Ultimately, we believe that, although methods need to improve and caution is required in interpretation, structural MRI continues to have great promise in furthering our understanding of how the brain works.

  15. An event-related functional MRI study on working memory impairment in children with primary nocturnal enuresis

    International Nuclear Information System (INIS)

    Yu Bing; Guo Qiyong; Fan Guoguang; Ma Hongwei; Wang Lu; Liu Na

    2010-01-01

    Objective: To assess the working memory and explore the activation of bra/n areas for children with primary nocturnal enuresis (PNE) with fMRI scan. Methods: Twenty three right-handed children with PNE and 20 age-matched right-handed healthy children as the controls were recruited. Intelligence tests were performed by means of Wechsler Young Children Scales of Intelligence (C-WISC) in children with PNE and normal controls. The full intelligence quotient (FIQ), verbal IQ (VIQ), performances IQ (PIQ) and the memory/caution (M/C) factor of PNE children and the controls were measured. After Intelligence tests, an event-related fMRI scan was performed using the categorical N-Back working memory task. Percent of correct responses (PCR) and mean reaction time to correct response (mRT) were recorded and analyzed by the student t test. The fMRI data were analyzed using Statistical Parametric Mapping 2 (SPM2), the differences in activation were compared between two groups. Results: The data of 15 PNE children and 15 healthy children were evaluated. The FIQ, VIQ and PIQ in PNE group were m a normal range and no statistical significance with the control group (P>0.05). M/C factor in the PNE group(90.4±10.2) was significantly lower than that in the control group (99.6±11.9) (t=2.260, P<0.05). In the N-Back test, PNE children had significantly less PCR [(72.7±6.3)% vs. (86.3± 6.7)%, t=5.727, P<0.01] and longer mRT [(625.8±72.5) ms vs. (534.8±63.3) ms, t=3.684, P<0.01] than the healthy controls. The activation regions of PNE patients and healthy children were mainly in the dorsal right frontal lobe, right parietal lobe, left temporal lobe gyrus fusiformis and bilateral cerebellum posterior lobe. The activation level in left posterior cerebellar lobe in PNE children was significant lower than that in healthy controls (P<0.01). Conclusion: The children with PNE have deficits in working memory which might be associated with the dysfunction of the left cerebellum. (authors)

  16. Cardiac diastolic dysfunction is associated with cerebral white matter lesions in elderly patients with risk factors for atherosclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Masugata, Hisashi; Senda, Shoichi; Goda, Fuminori [Kagawa Univ., Faculty of Medicine, Miki, Kagawa (Japan)

    2008-10-15

    Cerebral white matter lesions on magnetic resonance imaging (MRI) are considered to be the result of brain ischemic injury and a risk factor for clinical stroke. The purpose of this study was to elucidate the relationship between the cardiac diastolic function and cerebral white matter lesions in elderly patients with risk factors for atherosclerosis. The study subjects were 55 patients (75{+-}7 years) with risk factors for atherosclerosis including hypertension, diabetes mellitus, and dyslipidemia. Patients with symptomatic cerebrovascular events were excluded from the study. Cerebral white matter lesions, which were defined as exhibiting high intensity regions on brain MRI, were evaluated with the degrees of periventricular hyperintensity (PVH) according to the Japanese Brain Dock Guidelines of 2003. Peak early diastolic mitral annular velocity (E' velocity) was measured by tissue Doppler echocardiography, and was used as a parameter of cardiac diastolic function. The mean value of E' velocity was decreased due to the cardiac diastolic dysfunction (5.2{+-}1.4 cm/s). In addition, the E' velocity was inversely correlated with the degree of PVH ({rho}=-0.701, p<0.001). Stepwise regression analysis showed that the decrease in the E' velocity ({beta} coefficient=-0.42, p<0.001) and the presence of hypertension ({beta} coefficient=0.31, p=0.001) were independent determinants of the degree of PVH. Thus, cardiac diastolic dysfunction is correlated to the severity of cerebral white matter lesions, suggesting the cardio-cerebral connection in elderly patients with risk factors for atherosclerosis. (author)

  17. Ventricular Fibrillation-Induced Cardiac Arrest Results in Regional Cardiac Injury Preferentially in Left Anterior Descending Coronary Artery Territory in Piglet Model

    Directory of Open Access Journals (Sweden)

    Giridhar Kaliki Venkata

    2016-01-01

    Full Text Available Objective. Decreased cardiac function after resuscitation from cardiac arrest (CA results from global ischemia of the myocardium. In the evolution of postarrest myocardial dysfunction, preferential involvement of any coronary arterial territory is not known. We hypothesized that there is no preferential involvement of any coronary artery during electrical induced ventricular fibrillation (VF in piglet model. Design. Prospective, randomized controlled study. Methods. 12 piglets were randomized to baseline and electrical induced VF. After 5 min, the animals were resuscitated according to AHA PALS guidelines. After return of spontaneous circulation (ROSC, animals were observed for an additional 4 hours prior to cardiac MRI. Data (mean ± SD was analyzed using unpaired t-test; p value ≤ 0.05 was considered statistically significant. Results. Segmental wall motion (mm; baseline versus postarrest group in segment 7 (left anterior descending (LAD was 4.68±0.54 versus 3.31±0.64, p=0.0026. In segment 13, it was 3.82±0.96 versus 2.58±0.82, p=0.02. In segment 14, it was 2.42±0.44 versus 1.29±0.99, p=0.028. Conclusion. Postarrest myocardial dysfunction resulted in segmental wall motion defects in the LAD territory. There were no perfusion defects in the involved segments.

  18. Correction of MRI-induced geometric distortions in whole-body small animal PET-MRI

    International Nuclear Information System (INIS)

    Frohwein, Lynn J.; Schäfers, Klaus P.; Hoerr, Verena; Faber, Cornelius

    2015-01-01

    Purpose: The fusion of positron emission tomography (PET) and magnetic resonance imaging (MRI) data can be a challenging task in whole-body PET-MRI. The quality of the registration between these two modalities in large field-of-views (FOV) is often degraded by geometric distortions of the MRI data. The distortions at the edges of large FOVs mainly originate from MRI gradient nonlinearities. This work describes a method to measure and correct for these kind of geometric distortions in small animal MRI scanners to improve the registration accuracy of PET and MRI data. Methods: The authors have developed a geometric phantom which allows the measurement of geometric distortions in all spatial axes via control points. These control points are detected semiautomatically in both PET and MRI data with a subpixel accuracy. The spatial transformation between PET and MRI data is determined with these control points via 3D thin-plate splines (3D TPS). The transformation derived from the 3D TPS is finally applied to real MRI mouse data, which were acquired with the same scan parameters used in the phantom data acquisitions. Additionally, the influence of the phantom material on the homogeneity of the magnetic field is determined via field mapping. Results: The spatial shift according to the magnetic field homogeneity caused by the phantom material was determined to a mean of 0.1 mm. The results of the correction show that distortion with a maximum error of 4 mm could be reduced to less than 1 mm with the proposed correction method. Furthermore, the control point-based registration of PET and MRI data showed improved congruence after correction. Conclusions: The developed phantom has been shown to have no considerable negative effect on the homogeneity of the magnetic field. The proposed method yields an appropriate correction of the measured MRI distortion and is able to improve the PET and MRI registration. Furthermore, the method is applicable to whole-body small animal

  19. Correction of MRI-induced geometric distortions in whole-body small animal PET-MRI

    Energy Technology Data Exchange (ETDEWEB)

    Frohwein, Lynn J., E-mail: frohwein@uni-muenster.de; Schäfers, Klaus P. [European Institute for Molecular Imaging, University of Münster, Münster 48149 (Germany); Hoerr, Verena; Faber, Cornelius [Department of Clinical Radiology, University Hospital of Münster, Münster 48149 (Germany)

    2015-07-15

    Purpose: The fusion of positron emission tomography (PET) and magnetic resonance imaging (MRI) data can be a challenging task in whole-body PET-MRI. The quality of the registration between these two modalities in large field-of-views (FOV) is often degraded by geometric distortions of the MRI data. The distortions at the edges of large FOVs mainly originate from MRI gradient nonlinearities. This work describes a method to measure and correct for these kind of geometric distortions in small animal MRI scanners to improve the registration accuracy of PET and MRI data. Methods: The authors have developed a geometric phantom which allows the measurement of geometric distortions in all spatial axes via control points. These control points are detected semiautomatically in both PET and MRI data with a subpixel accuracy. The spatial transformation between PET and MRI data is determined with these control points via 3D thin-plate splines (3D TPS). The transformation derived from the 3D TPS is finally applied to real MRI mouse data, which were acquired with the same scan parameters used in the phantom data acquisitions. Additionally, the influence of the phantom material on the homogeneity of the magnetic field is determined via field mapping. Results: The spatial shift according to the magnetic field homogeneity caused by the phantom material was determined to a mean of 0.1 mm. The results of the correction show that distortion with a maximum error of 4 mm could be reduced to less than 1 mm with the proposed correction method. Furthermore, the control point-based registration of PET and MRI data showed improved congruence after correction. Conclusions: The developed phantom has been shown to have no considerable negative effect on the homogeneity of the magnetic field. The proposed method yields an appropriate correction of the measured MRI distortion and is able to improve the PET and MRI registration. Furthermore, the method is applicable to whole-body small animal

  20. A low-cost MRI compatible keyboard

    DEFF Research Database (Denmark)

    Jensen, Martin Snejbjerg; Heggli, Ole Adrian; Alves da Mota, Patricia

    2017-01-01

    , presenting a challenging environment for playing an instrument. Here, we present an MRI-compatible polyphonic keyboard with a materials cost of 850 $, designed and tested for safe use in 3T (three Tesla) MRI-scanners. We describe design considerations, and prior work in the field. In addition, we provide...

  1. Different brain activation under left and right ventricular stimulation: an fMRI study in anesthetized rats.

    Science.gov (United States)

    Suzuki, Hideaki; Sumiyoshi, Akira; Kawashima, Ryuta; Shimokawa, Hiroaki

    2013-01-01

    Myocardial ischemia in the anterior wall of the left ventricule (LV) and in the inferior wall and/or right ventricle (RV) shows different manifestations that can be explained by the different innervations of cardiac afferent nerves. However, it remains unclear whether information from different areas of the heart, such as the LV and RV, are differently processed in the brain. In this study, we investigated the brain regions that process information from the LV or RV using cardiac electrical stimulation and functional magnetic resonance imaging (fMRI) in anesthetized rats because the combination of these two approaches cannot be used in humans. An electrical stimulation catheter was inserted into the LV or RV (n = 12 each). Brain fMRI scans were recorded during LV or RV stimulation (9 Hz and 0.3 ms width) over 10 blocks consisting of alternating periods of 2 mA for 30 sec followed by 0.2 mA for 60 sec. The validity of fMRI signals was confirmed by first and second-level analyses and temporal profiles. Increases in fMRI signals were observed in the anterior cingulate cortex and the right somatosensory cortex under LV stimulation. In contrast, RV stimulation activated the right somatosensory cortex, which was identified more anteriorly compared with LV stimulation but did not activate the anterior cingulate cortex. This study provides the first evidence for differences in brain activation under LV and RV stimulation. These different brain processes may be associated with different clinical manifestations between anterior wall and inferoposterior wall and/or RV myocardial ischemia.

  2. Test-retest reliability of fMRI-based graph theoretical properties during working memory, emotion processing, and resting state.

    Science.gov (United States)

    Cao, Hengyi; Plichta, Michael M; Schäfer, Axel; Haddad, Leila; Grimm, Oliver; Schneider, Michael; Esslinger, Christine; Kirsch, Peter; Meyer-Lindenberg, Andreas; Tost, Heike

    2014-01-01

    The investigation of the brain connectome with functional magnetic resonance imaging (fMRI) and graph theory analyses has recently gained much popularity, but little is known about the robustness of these properties, in particular those derived from active fMRI tasks. Here, we studied the test-retest reliability of brain graphs calculated from 26 healthy participants with three established fMRI experiments (n-back working memory, emotional face-matching, resting state) and two parcellation schemes for node definition (AAL atlas, functional atlas proposed by Power et al.). We compared the intra-class correlation coefficients (ICCs) of five different data processing strategies and demonstrated a superior reliability of task-regression methods with condition-specific regressors. The between-task comparison revealed significantly higher ICCs for resting state relative to the active tasks, and a superiority of the n-back task relative to the face-matching task for global and local network properties. While the mean ICCs were typically lower for the active tasks, overall fair to good reliabilities were detected for global and local connectivity properties, and for the n-back task with both atlases, smallworldness. For all three tasks and atlases, low mean ICCs were seen for the local network properties. However, node-specific good reliabilities were detected for node degree in regions known to be critical for the challenged functions (resting-state: default-mode network nodes, n-back: fronto-parietal nodes, face-matching: limbic nodes). Between-atlas comparison demonstrated significantly higher reliabilities for the functional parcellations for global and local network properties. Our findings can inform the choice of processing strategies, brain atlases and outcome properties for fMRI studies using active tasks, graph theory methods, and within-subject designs, in particular future pharmaco-fMRI studies. © 2013 Elsevier Inc. All rights reserved.

  3. Diagnostic Value of MRI in Patients With Implanted Pacemakers and Implantable Cardioverter-Defibrillators Across a Cross Population: Does the Benefit Justify the Risk? A Proof of Concept Study.

    Science.gov (United States)

    Samar, Huma; Yamrozik, June A; Williams, Ronald B; Doyle, Mark; Shah, Moneal; Bonnet, Christopher A; Biederman, Robert W W

    2017-09-01

    The objective of this study was to assess the diagnostic usefulness of thoracic and nonthoracic magnetic resonance imaging (MRI) imaging in patients with implantable cardiac devices (permanent pacemaker or implantable cardioverter-defibrillators [ICDs]) to determine if there was a substantial benefit to patients with regard to diagnosis and/or management. MRI is infrequently performed on patients with conventional pacemakers or ICDs. Multiple studies have documented the safety of MRI scans in patients with implanted devices, yet the diagnostic value of this approach has not been established. Evaluation data were acquired in 136 patients with implanted cardiac devices who underwent MRIs during a 10-year period at a single institution. Specific criteria were followed for all patients to objectively define if the diagnosis by MRI enhanced patient care; 4 questions were answered after scan interpretation by both MRI technologists and MRI physicians who performed the scan. 1) Did the primary diagnosis change? 2) Did the MRI provide additional information to the existing diagnosis? 3) Was the pre-MRI (tentative) diagnosis confirmed? 4) Did patient management change? If "Yes" was answered to any of the preceding questions, the MRI scan was considered to be of value to patient diagnosis and/or therapy. In 97% (n = 132) of patients, MR added value to patient diagnosis and management. In 49% (n = 67) of patients, MRI added additional valuable information to the primary diagnosis, and in 30% (n = 41) of patients, MRI changed the principle diagnosis and subsequent management of the patient. No safety issues were encountered, and no adverse effects of undergoing the MRI scan were noted in any patient. MRI in patients with implanted pacemakers and defibrillators added value to patient diagnosis and management, which justified the risk of the procedure. Published by Elsevier Inc.

  4. Interference with cardiac pacemakers by magnetic resonance imaging: are there irreversible changes at 0.5 Tesla?

    Science.gov (United States)

    Vahlhaus, C; Sommer, T; Lewalter, T; Schimpf, R; Schumacher, B; Jung, W; Lüderitz, B

    2001-04-01

    The safety and feasibility of magnetic resonance imaging (MRI) in patients with cardiac pacemakers is an issue of gaining significance. The effect of MRI on patients' pacemaker systems has only been analyzed retrospectively in some case reports. Therefore, this study prospectively investigated if MRI causes irreversible changes in patients' pacemaker systems. The effect of MRI at 0.5 Tesla on sensing and stimulation thresholds, lead impedance and battery voltage, current, and impedance was estimated during 34 MRI examinations in 32 patients with implanted pacemakers. After measurements at baseline and with documentation of intrinsic rhythm and modification of the pacing mode, patients underwent MRI. The rest of the function time of the pacemaker was calculated. Measurements were again performed after 99.5 +/- 29.6 minutes (mean +/- SD), immediately after MRI examination, and 3 months later. Lead impedance and sensing and stimulation thresholds did not change after MRI. Battery voltage decreased immediately after MRI and recovered 3 months later. Battery current and impedance tended to increase. The calculated rest of function time did not change immediately after MRI. MRI affected neither pacemaker programmed data, nor the ability to interrogate, program, or use telemetry. Surprisingly, in the gantry of the scanner, temporary deactivation of the reed switch occurred in 12 of 32 patients when positioned in the center of the magnetic field. Missing activation of the reed switch through the static magnetic field at 0.5 Tesla is not unusual. MRI at 0.5 Tesla does not cause irreversible changes in patients' pacemaker systems.

  5. The effect of motivation on working memory: an fMRI and SEM study.

    Science.gov (United States)

    Szatkowska, Iwona; Bogorodzki, Piotr; Wolak, Tomasz; Marchewka, Artur; Szeszkowski, Wojciech

    2008-09-01

    This study investigated the effective connectivity between prefrontal regions of human brain supporting motivational influence on working memory. Functional magnetic resonance imaging (fMRI) and structural equation modeling (SEM) were used to examine the interaction between the lateral orbitofrontal (OFC), medial OFC, and dorsolateral prefrontal (DLPFC) regions in the left and right hemisphere during performance of the verbal 2-back working memory task under two reinforcement conditions. The "low-motivation" condition was not associated with monetary reinforcement, while the "high-motivation" condition involved the probability of winning a certain amount of money. In the "low-motivation" condition, the OFC regions in both hemispheres positively influenced the left DLPFC activity. In the "high-motivation" condition, the connectivity in the network including the right OFC regions and left DLPFC changed from positive to negative, whereas the positive connectivity in the network composed of the left OFC and left DLPFC became slightly enhanced compared with the "low-motivation" condition. However, only the connection between the right lateral OFC and left DLPFC showed a significant condition-dependent change in the strength of influence conveyed through the pathway. This change appears to be the functional correlate of motivational influence on verbal working memory.

  6. WE-G-BRD-09: Novel MRI Compatible Electron Accelerator for MRI-Linac Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Whelan, B; Keall, P [University of Sydney, Sydney (Australia); Gierman, S; Schmerge, J [SLAC National Accelerator Laboratory, Palo Alto, CA (United States); Holloway, L [Ingham Institute, Sydney, NSW (Australia); Fahrig, R [Stanford University, Stanford, CA (United States)

    2015-06-15

    Purpose: MRI guided radiotherapy is a rapidly growing field; however current linacs are not designed to operate in MRI fringe fields. As such, current MRI- Linac systems require magnetic shielding, impairing MR image quality and system flexibility. Here, we present a bespoke electron accelerator concept with robust operation in in-line magnetic fields. Methods: For in-line MRI-Linac systems, electron gun performance is the major constraint on accelerator performance. To overcome this, we propose placing a cathode directly within the first accelerating cavity. Such a configuration is used extensively in high energy particle physics, but not previously for radiotherapy. Benchmarked computational modelling (CST, Darmstadt, Germany) was employed to design and assess a 5.5 cell side coupled accelerator with a temperature limited thermionic cathode in the first accelerating cell. This simulation was coupled to magnetic fields from a 1T MRI model to assess robustness in magnetic fields for Source to Isocenter Distance between 1 and 2 meters. Performance was compared to a conventional electron gun based system in the same magnetic field. Results: A temperature limited cathode (work function 1.8eV, temperature 1245K, emission constant 60A/K/cm{sup 2}) will emit a mean current density of 24mA/mm{sup 2} (Richardson’s Law). We modeled a circular cathode with radius 2mm and mean current 300mA. Capture efficiency of the device was 43%, resulting in target current of 130 mA. The electron beam had a FWHM of 0.2mm, and mean energy of 5.9MeV (interquartile spread of 0.1MeV). Such an electron beam is suitable for radiotherapy, comparing favourably to conventional systems. This model was robust to operation the MRI fringe field, with a maximum current loss of 6% compared to 85% for the conventional system. Conclusion: The bespoke electron accelerator is robust to operation in in-line magnetic fields. This will enable MRI-Linacs with no accelerator magnetic shielding, and minimise

  7. High resolution MRI for preoperative work-up of neonates with an anorectal malformation: a direct comparison with distal pressure colostography/fistulography

    Energy Technology Data Exchange (ETDEWEB)

    Thomeer, Maarten G. [Erasmus MC, Department of Radiology, Rotterdam (Netherlands); Devos, Annick; Lequin, Maarten; Graaf, Nanko de; Meradji, Morteza [Erasmus MC, Department of Pediatric Radiology, Rotterdam (Netherlands); Meeussen, Conny J.H.M.; Blaauw, Ivo de; Sloots, Cornelius E.J. [Erasmus MC, Department of Pediatric Surgery, Rotterdam (Netherlands)

    2015-12-15

    To compare MRI and colostography/fistulography in neonates with anorectal malformations (ARM), using surgery as reference standard. Thirty-three neonates (22 boys) with ARM were included. All patients underwent both preoperative high-resolution MRI (without sedation or contrast instillation) and colostography/fistulography. The Krickenbeck classification was used to classify anorectal malformations, and the level of the rectal ending in relation to the levator muscle was evaluated. Subjects included nine patients with a bulbar recto-urethral fistula, six with a prostatic recto-urethral fistula, five with a vestibular fistula, five with a cloacal malformation, four without fistula, one with a H-type fistula, one with anal stenosis, one with a rectoperineal fistula and one with a bladderneck fistula. MRI and colostography/fistulography predicted anatomy in 88 % (29/33) and 61 % (20/33) of cases, respectively (p = 0.012). The distal end of the rectal pouch was correctly predicted in 88 % (29/33) and 67 % (22/33) of cases, respectively (p = 0.065). The length of the common channel in cloacal malformation was predicted with MRI in all (100 %, 5/5) and in 80 % of cases (4/5) with colostography/fistulography. Two bowel perforations occurred during colostography/fistulography. MRI provides the most accurate evaluation of ARM and should be considered a serious alternative to colostography/fistulography during preoperative work-up. (orig.)

  8. Motion correction options in PET/MRI.

    Science.gov (United States)

    Catana, Ciprian

    2015-05-01

    Subject motion is unavoidable in clinical and research imaging studies. Breathing is the most important source of motion in whole-body PET and MRI studies, affecting not only thoracic organs but also those in the upper and even lower abdomen. The motion related to the pumping action of the heart is obviously relevant in high-resolution cardiac studies. These two sources of motion are periodic and predictable, at least to a first approximation, which means certain techniques can be used to control the motion (eg, by acquiring the data when the organ of interest is relatively at rest). Additionally, nonperiodic and unpredictable motion can also occur during the scan. One obvious limitation of methods relying on external devices (eg, respiratory bellows or the electrocardiogram signal to monitor the respiratory or cardiac cycle, respectively) to trigger or gate the data acquisition is that the complex motion of internal organs cannot be fully characterized. However, detailed information can be obtained using either the PET or MRI data (or both) allowing the more complete characterization of the motion field so that a motion model can be built. Such a model and the information derived from simple external devices can be used to minimize the effects of motion on the collected data. In the ideal case, all the events recorded during the PET scan would be used to generate a motion-free or corrected PET image. The detailed motion field can be used for this purpose by applying it to the PET data before, during, or after the image reconstruction. Integrating all these methods for motion control, characterization, and correction into a workflow that can be used for routine clinical studies is challenging but could potentially be extremely valuable given the improvement in image quality and reduction of motion-related image artifacts. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Magnetic resonance imaging in familial hypertrophic cardiomyopathy associated with abnormal thallium perfusion and cardiac enzymes

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Tsunehiko; Nagata, Seiki; Sakakibara, Hiroshi

    1988-05-01

    Gated magnetic resonance imaging (MRI) was performed in 6 patients with familial hypertrophic cardiomyopathy associated with abnormal thallium perfusion, and 12 patients with ordinary hypertrophic cardiomyopathy. The patients with ordinary hypertrophic cardiomyopathy and abnormal thickening of the septal wall and normal left ventricular dimensions, while the patients with familial hypertrophic cardiomyopathy had focal wall thinning (usually involving the apical-septal wall) and dilated left ventricle in addition to hypertrophied heart. The quantitative measurement for cardiac dimensions using MRI was similar to that found on echocardiography in all cases. In addition, inhomogeneous signal intensities at left ventricular wall were observed in 3 cases of familial hypertrophic cardiomyopathy, which may suggest the existence of myocardial fibrosis. Gated MRI should be performed for early detection and follow-up of hypertrophic cardiomyopathy, since some patients will progress from hypertrophic cardiomyopathy to dilated cardiomyopathy.

  10. Cardiac and vascular malformations

    International Nuclear Information System (INIS)

    Ley, S.; Ley-Zaporozhan, J.

    2015-01-01

    Malformations of the heart and great vessels show a high degree of variation. There are numerous variants and defects with only few clinical manifestations and are only detected by chance, such as a persistent left superior vena cava or a partial anomalous pulmonary venous connection. Other cardiovascular malformations are manifested directly after birth and need prompt mostly surgical interventions. At this point in time echocardiography is the diagnostic modality of choice for morphological and functional characterization of malformations. Additional imaging using computed tomography (CT) or magnetic resonance imaging (MRI) is only required in a minority of cases. If so, the small anatomical structures, the physiological tachycardia and tachypnea are a challenge for imaging modalities and strategies. This review article presents the most frequent vascular, cardiac and complex cardiovascular malformations independent of the first line diagnostic imaging modality. (orig.) [de

  11. Direct comparison of high‐temporal‐resolution CINE MRI with Doppler ultrasound for assessment of diastolic dysfunction in mice

    Science.gov (United States)

    Price, Anthony N.; Jackson, Laurence H.; Taylor, Valerie; David, Anna L.; Lythgoe, Mark F.; Stuckey, Daniel J.

    2017-01-01

    Diastolic dysfunction is a sensitive early indicator of heart failure and can provide additional data to conventional measures of systolic function. Transmitral Doppler ultrasound, which measures the one‐dimensional flow of blood through the mitral valve, is currently the preferred method for the measurement of diastolic function, but the measurement of the left ventricular volume changes using high‐temporal‐resolution cinematic magnetic resonance imaging (CINE MRI) is an alternative approach which is emerging as a potentially more robust and user‐independent technique. Here, we investigated the performance of high‐temporal‐resolution CINE MRI and compared it with ultrasound for the detection of diastolic dysfunction in a mouse model of myocardial infarction. An in‐house, high‐temporal‐resolution, retrospectively gated CINE sequence was developed with a temporal resolution of 1 ms. Diastolic function in mice was assessed using a custom‐made, open‐source reconstruction package. Early (E) and late (A) left ventricular filling phases were easily identifiable, and these measurements were compared directly with high‐frequency, pulsed‐wave, Doppler ultrasound measurements of mitral valve inflow. A repeatability study established that high‐temporal‐resolution CINE MRI and Doppler ultrasound showed comparable accuracy when measuring E/A in normal control mice. However, when applied in a mouse model of myocardial infarction, high‐temporal‐resolution CINE MRI indicated diastolic heart failure (E/A = 0.94 ± 0.11), whereas ultrasound falsely detected normal cardiac function (E/A = 1.21 ± 0.11). The addition of high‐temporal‐resolution CINE MRI to preclinical imaging studies enhances the library of sequences available to cardiac researchers and potentially identifies diastolic heart failure early in disease progression. PMID:28643891

  12. Medulla oblongata damage and cardiac autonomic dysfunction in Parkinson disease.

    Science.gov (United States)

    Pyatigorskaya, Nadya; Mongin, Marie; Valabregue, Romain; Yahia-Cherif, Lydia; Ewenczyk, Claire; Poupon, Cyril; Debellemaniere, Eden; Vidailhet, Marie; Arnulf, Isabelle; Lehéricy, Stephane

    2016-12-13

    To characterize medulla oblongata damage using diffusion tensor imaging (DTI) in Parkinson disease (PD) and correlate it with dysfunction of the cardiac sympathetic/vagal balance. Fifty-two patients with PD and 24 healthy controls were included in the study. All participants underwent clinical examination and 3T MRI using 3D T1-weighted imaging and DTI. DTI metrics were calculated within manually drawn regions of interest. Heart rate variability was evaluated using spectral analysis of the R-R cardiac interval during REM and slow-wave sleep based on continuous overnight electrocardiographic monitoring. Respiratory frequency was measured in 30-second contiguous epochs of REM and slow-wave sleep. The relationships between imaging and cardiac variables were calculated using partial correlations followed by the multiple comparisons permutation approach. The changes in heart rate and respiratory frequency variability from slow-wave sleep to REM sleep in healthy controls were no longer detectable in patients with PD. There were significant increases in the mean (p = 0.006), axial (p = 0.006), and radial diffusivities (p = 0.005) in the medulla oblongata of patients with PD. In PD, diffusion changes were specifically correlated with a lower heart rate and respiratory frequency variability during REM sleep. This study provides evidence that medulla oblongata damage underlies cardiac sympathetic/vagal balance and respiratory dysfunction in patients with PD. © 2016 American Academy of Neurology.

  13. Contrast agents and cardiac MR imaging of myocardial ischemia: from bench to bedside

    International Nuclear Information System (INIS)

    Croisille, Pierre; Revel, Didier; Saeed, Maythem

    2006-01-01

    This review paper presents, in the first part, the different classes of contrast media that are already used or are in development for cardiac magnetic resonance imaging. A classification of the different types of contrast media is proposed based on the distribution of the compounds in the body, their type of relaxivity and their potential affinity to particular molecules. In the second part, the different uses of the extracellular type of T1-enhancing contrast agent for myocardial imaging is covered from the detection of stable coronary artery disease to the detection and characterization of chronic infarction. A particular emphasis is placed on the clinical use of gadolinium-chelates, which are the universally used type of MRI contrast agent in the clinical routine. Both approaches, first-pass magnetic resonance imaging (FP-MRI) as well as delayed-enhanced magnetic resonance imaging (DE-MRI), are covered in the different situations of acute and chronic myocardial infarction. (orig.)

  14. Whole-body MRI, dynamic contrast-enhanced MRI, and diffusion-weighted imaging for the staging of multiple myeloma

    Energy Technology Data Exchange (ETDEWEB)

    Dutoit, Julie C.; Verstraete, Koenraad L. [Ghent University Hospital, Department of Radiology, Ghent (Belgium)

    2017-06-15

    Magnetic resonance imaging (MRI) is the most sensitive imaging technique for the detection of bone marrow infiltration, and has therefore recently been included in the new diagnostic myeloma criteria, as proposed by the International Myeloma Working Group. Nevertheless, conventional MRI only provides anatomical information and is therefore only of limited use in the response assessment of patients with multiple myeloma. The additional information from functional MRI techniques, such as diffusion-weighted imaging and dynamic contrast-enhanced MRI, can improve the detection rate of bone marrow infiltration and the assessment of response. This can further enhance the sensitivity and specificity of MRI in the staging of multiple myeloma patients. This article provides an overview of the technical aspects of conventional and functional MRI techniques with practical recommendations. It reviews the diagnostic performance, prognostic value, and role in therapy assessment in multiple myeloma and its precursor stages. (orig.)

  15. Multimodality cardiac imaging of a ventricular septal rupture post myocardial infarction: a case report

    Directory of Open Access Journals (Sweden)

    Dhaliwal Surinder

    2012-10-01

    Full Text Available Abstract Background Ventricular septal rupture (VSR, a mechanical complication following an acute myocardial infarction (MI, is thought to result from coagulation necrosis due to lack of collateral reperfusion. Although the gold standard test to confirm left-to-right shunting between ventricular cavities remains invasive ventriculography, two-dimensional transthoracic echocardiography (TTE with color flow Doppler and cardiac MRI (CMR are reliable tests for the non-invasive diagnosis of VSR. Case presentation A 62-year-old Caucasian female presented with a late case of a VSR post inferior MI diagnosed by multimodality cardiac imaging including TTE, CMR and ventriculography. Conclusion We review the presentation, diagnosis and management of VSR post MI.

  16. Functional MRI study of verbal working memory in children with attention deficit hyperactivity disorder

    International Nuclear Information System (INIS)

    Lu Youran; Geng Daoying; Feng Xiaoyuan; Du Yasong; Zhao Zhimin

    2006-01-01

    Objective: To study the verbal working memory of children with attention deficit hyperactivity disorder (ADHD) as well as to explore the characteristics of functional areas of verbal working memory with blood oxygenation level dependent functional magnetic resonance imaging (fMRI). Method: Eighteen children were selected in the study. There were 9 ADHD children with inattention subtype and 9 healthy subjects. All patients and healthy subjects completed the cognitive examination and the block- designed N-block verbal working memory task using a GE 3.0 T MR. Data were analyzed by AFNI software. Result: The neural activations of ADHD's children are lower than that of control under verbal working memory. Especially in the areas of bilateral middle frontal gyri and inferior frontal gyri, bilateral superior parietal lobules and inferior parietal lobules, right basal ganglia in the 1-BACK task. And bilateral middle frontal gyri and inferior frontal gyri, bilateral superior parietal lobules, left cortex inferior parietallobule, right basal ganglia, anterior cingulatecortex in the 2-BACK task. Conclusion: The hypofunctional areas of verbal working memory (including bilateral dorsolateral prefrontal cortex and parietal cortex) can be seen in the ADHD children especially who also has lower activation of anterior cingulate cortex under 2-BACK task. (authors)

  17. fMRI response during spatial working memory in adolescent marijuana users : what is the relationship to recency of marijuana use?

    OpenAIRE

    Schweinsburg, Alecia Denise

    2006-01-01

    Marijuana is commonly used in adolescence, yet the impact on the developing brain is unclear. Working memory impairments have been observed in adult marijuana users after recent use, but may remit after a month of abstinence. The differential effects related to recent use and abstinence have not been delineated in adolescents. To address this question, three studies examined functional magnetic resonance imaging (fMRI) brain response during spatial working memory (SWM) among adolescents. Adol...

  18. Multiple skeletal muscle metastases revealing a cardiac intimal sarcoma

    Energy Technology Data Exchange (ETDEWEB)

    Crombe, Amandine [Institut Bergonie, Department of Radiology, Bordeaux (France); Lintingre, Pierre-Francois; Dallaudiere, Benjamin [Clinique du Sport de Bordeaux-Merignac, Department of Musculoskeletal Radiology, Merignac (France); Le Loarer, Francois [Institut Bergonie, Department of Pathology, Bordeaux (France); Lachatre, Denis [Dupuytren University Hospital, Department of Radiology, Limoges (France)

    2018-01-15

    We report the case of a 59-year-old female with progressive bilateral painful swelling of the thighs. MRI revealed multiple intramuscular necrotic masses with similar morphologic patterns. Whole-body CT and 18-FDG PET-CT scans demonstrated additional hypermetabolic muscular masses and a lobulated lesion within the left atrial cavity. As biopsy of a muscular mass was compatible with a poorly differentiated sarcoma with MDM2 oncogene amplification, two diagnoses were discussed: a dedifferentiated liposarcoma with muscle and heart metastases or a primary cardiac sarcoma, mainly a cardiac intimal sarcoma, with muscular metastases, which was finally confirmed by array-comparative genomic hybridization (aCGH) in a sarcoma reference center. This case emphasizes the potential for intimal sarcoma to disseminate in skeletal muscle prior to any other organ and the need for a genomic approach in addition to classical radiopathologic analyses to distinguish primary from secondary locations facing simultaneous tumors of the heart and skeletal muscles with MDM2 amplification. (orig.)

  19. MRI of the Chest

    Medline Plus

    Full Text Available ... or anesthesia. Alternatively, certain pediatric facilities have child life personnel who can work with younger children to help avoid the need ... MRI units may not provide this same image quality. Certain types of exams cannot be ... work? Unlike conventional x-ray examinations and computed tomography ( ...

  20. Impact of real-time fMRI working memory feedback training on the interactions between three core brain networks.

    Science.gov (United States)

    Zhang, Qiushi; Zhang, Gaoyan; Yao, Li; Zhao, Xiaojie

    2015-01-01

    Working memory (WM) refers to the temporary holding and manipulation of information during the performance of a range of cognitive tasks, and WM training is a promising method for improving an individual's cognitive functions. Our previous work demonstrated that WM performance can be improved through self-regulation of dorsal lateral prefrontal cortex (PFC) activation using real-time functional magnetic resonance imaging (rtfMRI), which enables individuals to control local brain activities volitionally according to the neurofeedback. Furthermore, research concerning large-scale brain networks has demonstrated that WM training requires the engagement of several networks, including the central executive network (CEN), the default mode network (DMN) and the salience network (SN), and functional connectivity within the CEN and DMN can be changed by WM training. Although a switching role of the SN between the CEN and DMN has been demonstrated, it remains unclear whether WM training can affect the interactions between the three networks and whether a similar mechanism also exists during the training process. In this study, we investigated the dynamic functional connectivity between the three networks during the rtfMRI feedback training using independent component analysis (ICA) and correlation analysis. The results indicated that functional connectivity within and between the three networks were significantly enhanced by feedback training, and most of the changes were associated with the insula and correlated with behavioral improvements. These findings suggest that the insula plays a critical role in the reorganization of functional connectivity among the three networks induced by rtfMRI training and in WM performance, thus providing new insights into the mechanisms of high-level functions and the clinical treatment of related functional impairments.

  1. Churg-Strauss syndrome cardiac involvement evaluated by cardiac magnetic resonance imaging and positron-emission tomography: a prospective study on 20 patients

    International Nuclear Information System (INIS)

    Marmursztejn, Julien; Guillevin, Loic; Cohen, Pascal; Guilpain, Philippe; Pagnoux, Christian; Mouthon, Luc; Trebossen, Regine; Legmann, Paul; Vignaux, Olivier; Duboc, Denis

    2013-01-01

    Churg-Strauss syndrome (CSS) cardiac involvement is associated with a poor prognosis. Recently cardiac MRI (CMRI) has emerged as a promising technique to detect early CSS cardiac involvement. However, CMRI-detected myocardial delayed enhancement (MDE) could correspond to fibrosis or inflammation. Fluoro-2-deoxyglucose PET (FDG-PET) was previously used in other systemic diseases to distinguish between them. To determine whether the CMRI-MDE detected in CSS patients reflected fibrosis or myocardial inflammation, patients in CSS remission underwent FDG-PET. Twenty consecutive CSS patients in remission (BVAS = 0) were recruited. Fourteen patients [eight men, six women; mean (S.D.) age 49 (9) years; mean disease duration 3.5 (2.9) years] with CMRI-detected MDE, and six patients [four men, two women; mean (S.D.) age 44 (15) years; mean disease duration 3.5 (5.3) years] with normal CMRI underwent FDG-PET. Segments with MDE on CMRI were analysed on FDG-PET images, with myocardial FDG hypo-fixation defining fibrosis and hyper-fixation corresponding inflammation. Among the 14 patients with MDE on CMRI, FDG-PET showed 10 had hypo-fixation, 2 had hyper-fixation and 2 had normal scans. CSS duration at the time of CMRI was shorter for patients with myocardial inflammation than in those with fibrosis. The six patients with normal CMRI had normal FDG-PET images. For CSS patients in remission, CMRI detected subclinical active myocardial lesions and could be recommended to assess cardiac involvement. However, because CMRI-detected MDE can reflect fibrosis or inflammation, FDG-PET might help to distinguish between the two. (authors)

  2. Churg-Strauss syndrome cardiac involvement evaluated by cardiac magnetic resonance imaging and positron-emission tomography: a prospective study on 20 patients

    Energy Technology Data Exchange (ETDEWEB)

    Marmursztejn, Julien [Department of Cardiology, Service Frederic Joliot CEA Orsay, Hopital Cochin, AP-HP, Universite Paris Descartes, Sorbonne Paris Cite, Paris, (France); Department of Radiology, Service Frederic Joliot CEA Orsay, Hopital Cochin, AP-HP, Universite Paris Descartes, Sorbonne Paris Cite, Paris, (France); Guillevin, Loic; Cohen, Pascal; Guilpain, Philippe; Pagnoux, Christian; Mouthon, Luc [Department of Internal Medicine, Service Frederic Joliot CEA Orsay, Hopital Cochin, AP-HP, Universite Paris Descartes, Sorbonne Paris Cite, Paris, (France); Trebossen, Regine [Department of Nuclear Medicine, Service Frederic Joliot CEA Orsay, Hopital Cochin, AP-HP, Universite Paris Descartes, Sorbonne Paris Cite, Paris, (France); Legmann, Paul; Vignaux, Olivier [Department of Radiology, Service Frederic Joliot CEA Orsay, Hopital Cochin, AP-HP, Universite Paris Descartes, Sorbonne Paris Cite, Paris, (France); Duboc, Denis [Department of Cardiology, Service Frederic Joliot CEA Orsay, Hopital Cochin, AP-HP, Universite Paris Descartes, Sorbonne Paris Cite, Paris, (France)

    2013-07-01

    Churg-Strauss syndrome (CSS) cardiac involvement is associated with a poor prognosis. Recently cardiac MRI (CMRI) has emerged as a promising technique to detect early CSS cardiac involvement. However, CMRI-detected myocardial delayed enhancement (MDE) could correspond to fibrosis or inflammation. Fluoro-2-deoxyglucose PET (FDG-PET) was previously used in other systemic diseases to distinguish between them. To determine whether the CMRI-MDE detected in CSS patients reflected fibrosis or myocardial inflammation, patients in CSS remission underwent FDG-PET. Twenty consecutive CSS patients in remission (BVAS = 0) were recruited. Fourteen patients [eight men, six women; mean (S.D.) age 49 (9) years; mean disease duration 3.5 (2.9) years] with CMRI-detected MDE, and six patients [four men, two women; mean (S.D.) age 44 (15) years; mean disease duration 3.5 (5.3) years] with normal CMRI underwent FDG-PET. Segments with MDE on CMRI were analysed on FDG-PET images, with myocardial FDG hypo-fixation defining fibrosis and hyper-fixation corresponding inflammation. Among the 14 patients with MDE on CMRI, FDG-PET showed 10 had hypo-fixation, 2 had hyper-fixation and 2 had normal scans. CSS duration at the time of CMRI was shorter for patients with myocardial inflammation than in those with fibrosis. The six patients with normal CMRI had normal FDG-PET images. For CSS patients in remission, CMRI detected subclinical active myocardial lesions and could be recommended to assess cardiac involvement. However, because CMRI-detected MDE can reflect fibrosis or inflammation, FDG-PET might help to distinguish between the two. (authors)

  3. Virtual cardiotomy based on 3-D MRI for preoperative planning in congenital heart disease

    International Nuclear Information System (INIS)

    Soerensen, Thomas Sangild; Beerbaum, Philipp; Razavi, Reza; Greil, Gerald Franz; Mosegaard, Jesper; Rasmusson, Allan; Schaeffter, Tobias; Austin, Conal

    2008-01-01

    Patient-specific preoperative planning in complex congenital heart disease may be greatly facilitated by virtual cardiotomy. Surgeons can perform an unlimited number of surgical incisions on a virtual 3-D reconstruction to evaluate the feasibility of different surgical strategies. To quantitatively evaluate the quality of the underlying imaging data and the accuracy of the corresponding segmentation, and to qualitatively evaluate the feasibility of virtual cardiotomy. A whole-heart MRI sequence was applied in 42 children with congenital heart disease (age 3±3 years, weight 13±9 kg, heart rate 96± 21 bpm). Image quality was graded 1-4 (diagnostic image quality ≥2) by two independent blinded observers. In patients with diagnostic image quality the segmentation quality was also graded 1-4 (4 no discrepancies, 1 misleading error). The average image quality score was 2.7 - sufficient for virtual reconstruction in 35 of 38 patients (92%) older than 1 month. Segmentation time was 59±10 min (average quality score 3.5). Virtual cardiotomy was performed in 19 patients. Accurate virtual reconstructions of patient-specific cardiac anatomy can be produced in less than 1 h from 3-D MRI. The presented work thus introduces a new, clinically feasible noninvasive technique for improved preoperative planning in complex cases of congenital heart disease. (orig.)

  4. Decrease in fMRI brain activation during working memory performed after sleeping under 10 lux light.

    Science.gov (United States)

    Kang, Seung-Gul; Yoon, Ho-Kyoung; Cho, Chul-Hyun; Kwon, Soonwook; Kang, June; Park, Young-Min; Lee, Eunil; Kim, Leen; Lee, Heon-Jeong

    2016-11-09

    The aim of this study was to investigate the effect of exposure to dim light at night (dLAN) when sleeping on functional brain activation during a working-memory tasks. We conducted the brain functional magnetic resonance imaging (fMRI) analysis on 20 healthy male subjects. All participants slept in a polysomnography laboratory without light exposure on the first and second nights and under a dim-light condition of either 5 or 10 lux on the third night. The fMRI scanning was conducted during n-back tasks after second and third nights. Statistical parametric maps revealed less activation in the right inferior frontal gyrus (IFG) after exposure to 10-lux light. The brain activity in the right and left IFG areas decreased more during the 2-back task than during the 1- or 0-back task in the 10-lux group. The exposure to 5-lux light had no significant effect on brain activities. The exposure to dLAN might influence the brain function which is related to the cognition.

  5. Cardiac diastolic dysfunction is associated with cerebral white matter lesions in elderly patients with risk factors for atherosclerosis

    International Nuclear Information System (INIS)

    Masugata, Hisashi; Senda, Shoichi; Goda, Fuminori

    2008-01-01

    Cerebral white matter lesions on magnetic resonance imaging (MRI) are considered to be the result of brain ischemic injury and a risk factor for clinical stroke. The purpose of this study was to elucidate the relationship between the cardiac diastolic function and cerebral white matter lesions in elderly patients with risk factors for atherosclerosis. The study subjects were 55 patients (75±7 years) with risk factors for atherosclerosis including hypertension, diabetes mellitus, and dyslipidemia. Patients with symptomatic cerebrovascular events were excluded from the study. Cerebral white matter lesions, which were defined as exhibiting high intensity regions on brain MRI, were evaluated with the degrees of periventricular hyperintensity (PVH) according to the Japanese Brain Dock Guidelines of 2003. Peak early diastolic mitral annular velocity (E' velocity) was measured by tissue Doppler echocardiography, and was used as a parameter of cardiac diastolic function. The mean value of E' velocity was decreased due to the cardiac diastolic dysfunction (5.2±1.4 cm/s). In addition, the E' velocity was inversely correlated with the degree of PVH (ρ=-0.701, p<0.001). Stepwise regression analysis showed that the decrease in the E' velocity (β coefficient=-0.42, p<0.001) and the presence of hypertension (β coefficient=0.31, p=0.001) were independent determinants of the degree of PVH. Thus, cardiac diastolic dysfunction is correlated to the severity of cerebral white matter lesions, suggesting the cardio-cerebral connection in elderly patients with risk factors for atherosclerosis. (author)

  6. Quantitative Myocardial Perfusion with Dynamic Contrast-Enhanced Imaging in MRI and CT: Theoretical Models and Current Implementation

    Directory of Open Access Journals (Sweden)

    G. J. Pelgrim

    2016-01-01

    Full Text Available Technological advances in magnetic resonance imaging (MRI and computed tomography (CT, including higher spatial and temporal resolution, have made the prospect of performing absolute myocardial perfusion quantification possible, previously only achievable with positron emission tomography (PET. This could facilitate integration of myocardial perfusion biomarkers into the current workup for coronary artery disease (CAD, as MRI and CT systems are more widely available than PET scanners. Cardiac PET scanning remains expensive and is restricted by the requirement of a nearby cyclotron. Clinical evidence is needed to demonstrate that MRI and CT have similar accuracy for myocardial perfusion quantification as PET. However, lack of standardization of acquisition protocols and tracer kinetic model selection complicates comparison between different studies and modalities. The aim of this overview is to provide insight into the different tracer kinetic models for quantitative myocardial perfusion analysis and to address typical implementation issues in MRI and CT. We compare different models based on their theoretical derivations and present the respective consequences for MRI and CT acquisition parameters, highlighting the interplay between tracer kinetic modeling and acquisition settings.

  7. Mathematical Models of Cardiac Pacemaking Function

    Science.gov (United States)

    Li, Pan; Lines, Glenn T.; Maleckar, Mary M.; Tveito, Aslak

    2013-10-01

    Over the past half century, there has been intense and fruitful interaction between experimental and computational investigations of cardiac function. This interaction has, for example, led to deep understanding of cardiac excitation-contraction coupling; how it works, as well as how it fails. However, many lines of inquiry remain unresolved, among them the initiation of each heartbeat. The sinoatrial node, a cluster of specialized pacemaking cells in the right atrium of the heart, spontaneously generates an electro-chemical wave that spreads through the atria and through the cardiac conduction system to the ventricles, initiating the contraction of cardiac muscle essential for pumping blood to the body. Despite the fundamental importance of this primary pacemaker, this process is still not fully understood, and ionic mechanisms underlying cardiac pacemaking function are currently under heated debate. Several mathematical models of sinoatrial node cell membrane electrophysiology have been constructed as based on different experimental data sets and hypotheses. As could be expected, these differing models offer diverse predictions about cardiac pacemaking activities. This paper aims to present the current state of debate over the origins of the pacemaking function of the sinoatrial node. Here, we will specifically review the state-of-the-art of cardiac pacemaker modeling, with a special emphasis on current discrepancies, limitations, and future challenges.

  8. A computationally efficient OMP-based compressed sensing reconstruction for dynamic MRI

    International Nuclear Information System (INIS)

    Usman, M; Prieto, C; Schaeffter, T; Batchelor, P G; Odille, F; Atkinson, D

    2011-01-01

    Compressed sensing (CS) methods in MRI are computationally intensive. Thus, designing novel CS algorithms that can perform faster reconstructions is crucial for everyday applications. We propose a computationally efficient orthogonal matching pursuit (OMP)-based reconstruction, specifically suited to cardiac MR data. According to the energy distribution of a y-f space obtained from a sliding window reconstruction, we label the y-f space as static or dynamic. For static y-f space images, a computationally efficient masked OMP reconstruction is performed, whereas for dynamic y-f space images, standard OMP reconstruction is used. The proposed method was tested on a dynamic numerical phantom and two cardiac MR datasets. Depending on the field of view composition of the imaging data, compared to the standard OMP method, reconstruction speedup factors ranging from 1.5 to 2.5 are achieved. (note)

  9. Strain-encoded cardiac MRI as an adjunct for dobutamine stress testing: incremental value to conventional wall motion analysis.

    Science.gov (United States)

    Korosoglou, Grigorios; Lossnitzer, Dirk; Schellberg, Dieter; Lewien, Antje; Wochele, Angela; Schaeufele, Tim; Neizel, Mirja; Steen, Henning; Giannitsis, Evangelos; Katus, Hugo A; Osman, Nael F

    2009-03-01

    High-dose dobutamine stress MRI is safe and feasible for the diagnosis of coronary artery disease (CAD) in humans. However, the assessment of cine scans relies on the visual interpretation of regional wall motion, which is subjective. Recently, strain-encoded MRI (SENC) has been proposed for the direct color-coded visualization of myocardial strain. The purpose of our study was to compare the diagnostic value of SENC with that provided by conventional wall motion analysis for the detection of inducible ischemia during dobutamine stress MRI. Stress-induced ischemia was assessed by wall motion analysis and by SENC in 101 patients with suspected or known CAD and in 17 healthy volunteers who underwent dobutamine stress MRI in a clinical 1.5-T scanner. Quantitative coronary angiography deemed as the standard reference for the presence or absence of significant CAD (> or =50% diameter stenosis). On a coronary vessel level, SENC detected inducible ischemia in 86 of 101 versus 71 of 101 diseased coronary vessels (P or =50% stenosis (area under the curve, 0.96; SE, 0.01; 95% CI, 0.94 to 0.98; P<0.001). The direct color-coded visualization of strain on MR images is a useful adjunct for dobutamine stress MRI, which provides incremental value for the detection of CAD compared with conventional wall motion readings on cine images.

  10. First experience of simultaneous PET/MRI for the early detection of cardiac involvement in patients with Anderson-Fabry disease

    Energy Technology Data Exchange (ETDEWEB)

    Nappi, Carmela; Altiero, Michele; Imbriaco, Massimo; Giudice, Caterina Anna; Spinelli, Letizia; Cuocolo, Alberto [University Federico II, Department of Advanced Biomedical Sciences, Naples (Italy); Nicolai, Emanuele; Aiello, Marco; Diomiaiuti, Claudio Tommaso [IRCCS SDN, Naples (Italy); Pisani, Antonio [University Federico II, Department of Public Health, Naples (Italy)

    2015-03-26

    Anderson-Fabry disease (AFD) is an X-linked lysosomal storage disorder associated with severe multiorgan dysfunction and premature death. Early diagnosis and treatment strategies play a key role in patient outcome. We investigated the potential role of hybrid PET/MR imaging in the assessment of early cardiac involvement in AFD patients. Thirteen AFD patients without cardiac symptoms and with normal left ventricular function underwent simultaneous cardiac PET/MR imaging after administration of {sup 18}F-FDG. Cardiac FDG uptake was quantified by measuring the standardized uptake value in 17 myocardial segments in each subject. The coefficient of variation (COV, i.e. the standard deviation divided by the average) of the uptake of the 17 segments was calculated as an index of heterogeneity in the heart. Six patients exhibited focal late gadolinium enhancement (LGE) indicating intramyocardial fibrosis, and four of these also had positive short inversion time inversion recovery (STIR) sequences. All patients with LGE and positive STIR MR images showed focal FDG uptake in the corresponding myocardial segments indicating inflammation. Of the seven patients with negative LGE and STIR images, five showed homogeneous FDG cardiac uptake and two showed heterogeneous FDG uptake. The COV was significantly greater in patients with focal FDG uptake (0.25 ± 0.02) than in those without (0.14 ± 0.07, p < 0.01). PET/MR imaging is clinically feasible for the early detection of cardiac involvement in patients with AFD. Further studies evaluating the role of hybrid PET/MR imaging in management of the disease in larger patient populations are warranted. (orig.)

  11. First experience of simultaneous PET/MRI for the early detection of cardiac involvement in patients with Anderson-Fabry disease

    International Nuclear Information System (INIS)

    Nappi, Carmela; Altiero, Michele; Imbriaco, Massimo; Giudice, Caterina Anna; Spinelli, Letizia; Cuocolo, Alberto; Nicolai, Emanuele; Aiello, Marco; Diomiaiuti, Claudio Tommaso; Pisani, Antonio

    2015-01-01

    Anderson-Fabry disease (AFD) is an X-linked lysosomal storage disorder associated with severe multiorgan dysfunction and premature death. Early diagnosis and treatment strategies play a key role in patient outcome. We investigated the potential role of hybrid PET/MR imaging in the assessment of early cardiac involvement in AFD patients. Thirteen AFD patients without cardiac symptoms and with normal left ventricular function underwent simultaneous cardiac PET/MR imaging after administration of 18 F-FDG. Cardiac FDG uptake was quantified by measuring the standardized uptake value in 17 myocardial segments in each subject. The coefficient of variation (COV, i.e. the standard deviation divided by the average) of the uptake of the 17 segments was calculated as an index of heterogeneity in the heart. Six patients exhibited focal late gadolinium enhancement (LGE) indicating intramyocardial fibrosis, and four of these also had positive short inversion time inversion recovery (STIR) sequences. All patients with LGE and positive STIR MR images showed focal FDG uptake in the corresponding myocardial segments indicating inflammation. Of the seven patients with negative LGE and STIR images, five showed homogeneous FDG cardiac uptake and two showed heterogeneous FDG uptake. The COV was significantly greater in patients with focal FDG uptake (0.25 ± 0.02) than in those without (0.14 ± 0.07, p < 0.01). PET/MR imaging is clinically feasible for the early detection of cardiac involvement in patients with AFD. Further studies evaluating the role of hybrid PET/MR imaging in management of the disease in larger patient populations are warranted. (orig.)

  12. Burnout versus work engagement in their effects on 24-hour ambulatory monitored cardiac autonomic function

    NARCIS (Netherlands)

    L.J.P. van Doornen (Lorenz); J.H. Houtveen (Jan); S. Langelaan (Saar); A.B. Bakker (Arnold); W. van Rhenen (Willem); W.B. Schaufeli (Wilmar)

    2009-01-01

    textabstractBurnout has been associated with increased risk of cardiovascular disease. This relationship may be mediated by a stress-related disruption in cardiac autonomic activity. The aim of the present study was to assess cardiac autonomic activity (sympathetic and parasympathetic) during a

  13. Cardiac regeneration therapy: connections to cardiac physiology.

    Science.gov (United States)

    Takehara, Naofumi; Matsubara, Hiroaki

    2011-12-01

    Without heart transplantation, a large number of patients with failing hearts worldwide face poor outcomes. By means of cardiomyocyte regeneration, cardiac regeneration therapy is emerging with great promise as a means for restoring loss of cardiac function. However, the limited success of clinical trials using bone marrow-derived cells and myoblasts with heterogeneous constituents, transplanted at a wide range of cell doses, has led to disagreement on the efficacy of cell therapy. It is therefore essential to reevaluate the evidence for the efficacy of cell-based cardiac regeneration therapy, focusing on targets, materials, and methodologies. Meanwhile, the revolutionary innovation of cardiac regeneration therapy is sorely needed to help the millions of people who suffer heart failure from acquired loss of cardiomyocytes. Cardiac regeneration has been used only in limited species or as a developing process in the rodent heart; now, the possibility of cardiomyocyte turnover in the human heart is being revisited. In the pursuit of this concept, the use of cardiac stem/progenitor stem cells in the cardiac niche must be focused to usher in a second era of cardiac regeneration therapy for the severely injured heart. In addition, tissue engineering and cellular reprogramming will advance the next era of treatment that will enable current cell-based therapy to progress to "real" cardiac regeneration therapy. Although many barriers remain, the prevention of refractory heart failure through cardiac regeneration is now becoming a realistic possibility.

  14. Direct comparison of high-temporal-resolution CINE MRI with Doppler ultrasound for assessment of diastolic dysfunction in mice.

    Science.gov (United States)

    Roberts, Thomas A; Price, Anthony N; Jackson, Laurence H; Taylor, Valerie; David, Anna L; Lythgoe, Mark F; Stuckey, Daniel J

    2017-10-01

    Diastolic dysfunction is a sensitive early indicator of heart failure and can provide additional data to conventional measures of systolic function. Transmitral Doppler ultrasound, which measures the one-dimensional flow of blood through the mitral valve, is currently the preferred method for the measurement of diastolic function, but the measurement of the left ventricular volume changes using high-temporal-resolution cinematic magnetic resonance imaging (CINE MRI) is an alternative approach which is emerging as a potentially more robust and user-independent technique. Here, we investigated the performance of high-temporal-resolution CINE MRI and compared it with ultrasound for the detection of diastolic dysfunction in a mouse model of myocardial infarction. An in-house, high-temporal-resolution, retrospectively gated CINE sequence was developed with a temporal resolution of 1 ms. Diastolic function in mice was assessed using a custom-made, open-source reconstruction package. Early (E) and late (A) left ventricular filling phases were easily identifiable, and these measurements were compared directly with high-frequency, pulsed-wave, Doppler ultrasound measurements of mitral valve inflow. A repeatability study established that high-temporal-resolution CINE MRI and Doppler ultrasound showed comparable accuracy when measuring E/A in normal control mice. However, when applied in a mouse model of myocardial infarction, high-temporal-resolution CINE MRI indicated diastolic heart failure (E/A = 0.94 ± 0.11), whereas ultrasound falsely detected normal cardiac function (E/A = 1.21 ± 0.11). The addition of high-temporal-resolution CINE MRI to preclinical imaging studies enhances the library of sequences available to cardiac researchers and potentially identifies diastolic heart failure early in disease progression. © 2017 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.

  15. Exposure to MRI-related magnetic fields and vertigo in MRI workers

    NARCIS (Netherlands)

    Schaap, Kristel; Portengen, Lutzen; Kromhout, Hans

    OBJECTIVES: Vertigo has been reported by people working around magnetic resonance imaging (MRI) scanners and was found to increase with increasing strength of scanner magnets. This suggests an association with exposure to static magnetic fields (SMF) and/or motion-induced time-varying magnetic

  16. Role of cardiac magnetic resonance imaging focusing on QOL and preventive medicine

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Ito, Hirotoshi; Kubota, Takao

    2003-01-01

    Cardiac magnetic resonance imaging (MRI) using fast imaging techniques has been developing quickly recently. Left ventricular function with pharmacological intervention can be evaluated using True fast imaging with steady-state precession (FISP) method. In addition, left ventricular diastolic function can be evaluated by retrospective gating with a high frame rate. Myocardial perfusion and viability can also be evaluated by first-pass imaging and delayed enhancement with Gd-DTPA. Data concerning myocardial ischemia, viability, and left ventricular function is now almost equivalent to that of myocardial SPECT and contrast echo. Additionally, coronary arterial narrowing and coronary vessel wall can be visualized with both the bright-blood and black-blood method. These methods are still currently in the research stage. The prognostic value of myocardial perfusion and ventricular function in ischemic heart disease should be established using large numbers of patients. Multi-center trials using cardiac MRI should be recommended for this purpose. Furthermore, detecting acute coronary syndrome in the emergency department can be performed with safety and accuracy. MR coronary angiography should be used not only for flow-limiting coronary stenosis but also the atherosclerotic wall region. This provides information that may predict cardiovascular risk, and facilitate further study of artherothrombosis, progression and response to therapy. It may also provide for the assessment of subclinical disease. (author)

  17. Automatic cardiac cycle determination directly from EEG-fMRI data by multi-scale peak detection method.

    Science.gov (United States)

    Wong, Chung-Ki; Luo, Qingfei; Zotev, Vadim; Phillips, Raquel; Chan, Kam Wai Clifford; Bodurka, Jerzy

    2018-03-31

    In simultaneous EEG-fMRI, identification of the period of cardioballistic artifact (BCG) in EEG is required for the artifact removal. Recording the electrocardiogram (ECG) waveform during fMRI is difficult, often causing inaccurate period detection. Since the waveform of the BCG extracted by independent component analysis (ICA) is relatively invariable compared to the ECG waveform, we propose a multiple-scale peak-detection algorithm to determine the BCG cycle directly from the EEG data. The algorithm first extracts the high contrast BCG component from the EEG data by ICA. The BCG cycle is then estimated by band-pass filtering the component around the fundamental frequency identified from its energy spectral density, and the peak of BCG artifact occurrence is selected from each of the estimated cycle. The algorithm is shown to achieve a high accuracy on a large EEG-fMRI dataset. It is also adaptive to various heart rates without the needs of adjusting the threshold parameters. The cycle detection remains accurate with the scan duration reduced to half a minute. Additionally, the algorithm gives a figure of merit to evaluate the reliability of the detection accuracy. The algorithm is shown to give a higher detection accuracy than the commonly used cycle detection algorithm fmrib_qrsdetect implemented in EEGLAB. The achieved high cycle detection accuracy of our algorithm without using the ECG waveforms makes possible to create and automate pipelines for processing large EEG-fMRI datasets, and virtually eliminates the need for ECG recordings for BCG artifact removal. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  18. Rate of cardiac arrhythmias and silent brain lesions in experienced marathon runners: rationale, design and baseline data of the Berlin Beat of Running study

    Directory of Open Access Journals (Sweden)

    Haeusler Karl

    2012-08-01

    Full Text Available Abstract Background Regular exercise is beneficial for cardiovascular health but a recent meta-analysis indicated a relationship between extensive endurance sport and a higher risk of atrial fibrillation, an independent risk factor for stroke. However, data on the frequency of cardiac arrhythmias or (clinically silent brain lesions during and after marathon running are missing. Methods/ Design In the prospective observational “Berlin Beat of Running” study experienced endurance athletes underwent clinical examination (CE, 3 Tesla brain magnetic resonance imaging (MRI, carotid ultrasound imaging (CUI and serial blood sampling (BS within 2-3 days prior (CE, MRI, CUI, BS, directly after (CE, BS and within 2 days after (CE, MRI, BS the 38th BMW BERLIN-MARATHON 2011. All participants wore a portable electrocardiogram (ECG-recorder throughout the 4 to 5 days baseline study period. Participants with pathological MRI findings after the marathon, troponin elevations or detected cardiac arrhythmias will be asked to undergo cardiac MRI to rule out structural abnormalities. A follow-up is scheduled after one year. Results Here we report the baseline data of the enrolled 110 athletes aged 36-61 years. Their mean age was 48.8 ± 6.0 years, 24.5% were female, 8.2% had hypertension and 2.7% had hyperlipidaemia. Participants have attended a mean of 7.5 ± 6.6 marathon races within the last 5 years and a mean of 16 ± 36 marathon races in total. Their weekly running distance prior to the 38th BMW BERLIN-MARATHON was 65 ± 17 km. Finally, 108 (98.2% Berlin Beat-Study participants successfully completed the 38th BMW BERLIN-MARATHON 2011. Discussion Findings from the “Berlin Beats of Running” study will help to balance the benefits and risks of extensive endurance sport. ECG-recording during the marathon might contribute to identify athletes at risk for cardiovascular events. MRI results will give new insights into the link

  19. Updating working memory in aircraft noise and speech noise causes different fMRI activations.

    Science.gov (United States)

    Saetrevik, Bjørn; Sörqvist, Patrik

    2015-02-01

    The present study used fMRI/BOLD neuroimaging to investigate how visual-verbal working memory is updated when exposed to three different background-noise conditions: speech noise, aircraft noise and silence. The number-updating task that was used can distinguish between "substitution processes," which involve adding new items to the working memory representation and suppressing old items, and "exclusion processes," which involve rejecting new items and maintaining an intact memory set. The current findings supported the findings of a previous study by showing that substitution activated the dorsolateral prefrontal cortex, the posterior medial frontal cortex and the parietal lobes, whereas exclusion activated the anterior medial frontal cortex. Moreover, the prefrontal cortex was activated more by substitution processes when exposed to background speech than when exposed to aircraft noise. These results indicate that (a) the prefrontal cortex plays a special role when task-irrelevant materials should be denied access to working memory and (b) that, when compensating for different types of noise, either different cognitive mechanisms are involved or those cognitive mechanisms that are involved are involved to different degrees. © 2014 The Authors. Scandinavian Journal of Psychology published by Scandinavian Psychological Associations and John Wiley & Sons Ltd.

  20. Inefficient preparatory fMRI-BOLD network activations predict working memory dysfunctions in patients with schizophrenia

    Directory of Open Access Journals (Sweden)

    Anja eBaenninger

    2016-03-01

    Full Text Available Patients with schizophrenia show abnormal dynamics and structure of temporally coherent networks (TCNs assessed using fMRI, which undergo adaptive shifts in preparation for a cognitively demanding task. During working memory (WM tasks, patients with schizophrenia show persistent deficits in TCNs as well as EEG indices of WM. Studying their temporal relationship during WM tasks might provide novel insights into WM performance deficits seen in schizophrenia.Simultaneous EEG-fMRI data were acquired during the performance of a verbal Sternberg WM task with two load levels (load 2 & load 5 in 17 patients with schizophrenia and 17 matched healthy controls. Using covariance mapping, we investigated the relationship of the activity in the TCNs before the memoranda were encoded and EEG spectral power during the retention interval. We assessed four TCNs – default mode network (DMN, dorsal attention network (dAN, left and right working memory networks (WMNs – and three EEG bands – theta, alpha, and beta.In healthy controls, there was a load dependent inverse relation between DMN and frontal-midline theta power and an anti-correlation between DMN and dAN. Both effects were not significantly detectable in patients. In addition, healthy controls showed a left-lateralized load-dependent recruitment of the WMNs. Activation of the WMNs was bilateral in patients, suggesting more resources were recruited for successful performance on the WM task.Our findings support the notion of schizophrenia patients showing deviations in their neurophysiological responses before the retention of relevant information in a verbal WM task. Thus, treatment strategies as neurofeedback targeting pre-states could be beneficial as task performance relies on the preparatory state of the brain.

  1. The cardiac sonography workforce in New Zealand

    Science.gov (United States)

    White, Steve; Poppe, Katrina; Whalley, Gillian

    2015-01-01

    Abstract Introduction: The aim of this paper is to investigate the cardiac sonography workforce characteristics and registration requirements in New Zealand (NZ), with a comparison to similar workforces internationally. Methods: The Survey of Clinical Echocardiography in New Zealand 2 (SCANZ2) audit was performed in December 2010. All of NZ's public‐funded District Health Board (DHB) centers providing echocardiography services responded to questions relating to staff, equipment, procedure types and patient statistics. The Medical Radiation Technologists Board (MRTB), Clinical Physiologists Registration Board (CPRB) and Australian Sonographers Association Registry (ASAR) websites were reviewed in March 2012 for registered sonographers with a cardiac scope of practice. The cardiac sonography workforces in Australia, the UK, the USA and Canada were investigated for comparison. Results: There are 84 cardiac sonographers (60.3 full‐time equivalent) working in DHBs: 71% from a cardiac technical background; 40% have post‐graduate qualifications; a further 17% are undertaking post‐graduate qualifications; and 59 cardiac sonographers have registration with professional bodies in NZ and/or Australia. Cardiac sonographers in NZ do not undergo compulsory registration, but other sonographers in NZ have compulsory registration with the MRTB. Sonographers are predominantly not licensed internationally. Discussion: Disparity exists between registration of cardiac and non‐cardiac sonographers in NZ. Many cardiac sonographers have voluntary registration but few are registered with the MRTB. Reasons for this include professional alignment, educational qualifications and representation. International trends show increased pressure from governments and professional bodies to regulate sonographers. Conclusion: This study provides a snapshot of the cardiac sonography workforce in NZ for the first time. PMID:28191178

  2. Initial experience with lung-MRI at 3.0 T: Comparison with CT and clinical data in the evaluation of interstitial lung disease activity

    International Nuclear Information System (INIS)

    Lutterbey, G.; Grohe, C.; Gieseke, J.; Falkenhausen, M. von; Morakkabati, N.; Wattjes, M.P.; Manka, R.; Trog, D.; Schild, H.H.

    2007-01-01

    Objectives: We evaluated the feasibility of highfield lung-MRI at 3.0 T. A comparison with Computed Tomography (CT) and clinical data regarding the assessment of inflammatory activity in patients with diffuse lung disease was performed. Material and methods: Prospective evaluation of 21 patients (15 males, 6 females, 43-80 y) with diffuse lung diseases who underwent clinical work-up inclusive laboratory tests, lung-function tests and transbronchial biopsy. After routine helical CT (additional 12 HRCT) a lung-MRI (3.0 Intera, Philips Medical Systems, Best, The Netherlands) using a T2-weighted, cardiac and respiratory triggered Fast-Spinecho-Sequence (TE/TR = 80/1500-2500 ms, 22 transverse slices, 7/2 mm slice-thickness/-gap) was performed. A pneumologist classified the cases into two groups: A = temporary acute interstitial disease or chronic interstitial lung disease with acute episode or superimposed infection/B = burned out interstitial lung disease without activity. Two blinded CT-radiologists graded the cases in active/inactive disease on the basis of nine morphological criteria each. A third radiologist rated the MRI-cases as active/inactive, depending on the signal-intensities of lung tissues. Results: The pneumologist classified 14 patients into group A and 7 patients into group B. Using CT, 6 cases were classified as active, 15 cases as inactive disease. With MRI 12 cases were classified as active and 9 cases as inactive. In the complete group of 21 patients MRI decisions and CT decisions respectively were false positive/false negative/correct in 2/4/15 respectively 0/8/13 cases. Correct diagnoses were obtained in 72% (MRI) respectively 62% (CT). In the subgroup of 12 cases including HRCT, MRI respectively CT were false positive/false negative/correct in 2/1/9 respectively 0/5/7 cases. Correct diagnoses were obtained in 75% (MRI) respectively 58% (CT). Conclusion: Highfield MRI of the lung is feasible and performed slightly better compared to CT in the

  3. Initial experience with lung-MRI at 3.0 T: Comparison with CT and clinical data in the evaluation of interstitial lung disease activity

    Energy Technology Data Exchange (ETDEWEB)

    Lutterbey, G. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany)]. E-mail: goetz.lutterbey@ukb.uni-bonn.de; Grohe, C. [Department of Internal Medicine, University of Bonn (Germany); Gieseke, J. [PHILIPS Medical Systems, Best (Netherlands); Falkenhausen, M. von [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany); Morakkabati, N. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany); Wattjes, M.P. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany); Manka, R. [Department of Internal Medicine, University of Bonn (Germany); Trog, D. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany); Schild, H.H. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany)

    2007-02-15

    Objectives: We evaluated the feasibility of highfield lung-MRI at 3.0 T. A comparison with Computed Tomography (CT) and clinical data regarding the assessment of inflammatory activity in patients with diffuse lung disease was performed. Material and methods: Prospective evaluation of 21 patients (15 males, 6 females, 43-80 y) with diffuse lung diseases who underwent clinical work-up inclusive laboratory tests, lung-function tests and transbronchial biopsy. After routine helical CT (additional 12 HRCT) a lung-MRI (3.0 Intera, Philips Medical Systems, Best, The Netherlands) using a T2-weighted, cardiac and respiratory triggered Fast-Spinecho-Sequence (TE/TR = 80/1500-2500 ms, 22 transverse slices, 7/2 mm slice-thickness/-gap) was performed. A pneumologist classified the cases into two groups: A = temporary acute interstitial disease or chronic interstitial lung disease with acute episode or superimposed infection/B = burned out interstitial lung disease without activity. Two blinded CT-radiologists graded the cases in active/inactive disease on the basis of nine morphological criteria each. A third radiologist rated the MRI-cases as active/inactive, depending on the signal-intensities of lung tissues. Results: The pneumologist classified 14 patients into group A and 7 patients into group B. Using CT, 6 cases were classified as active, 15 cases as inactive disease. With MRI 12 cases were classified as active and 9 cases as inactive. In the complete group of 21 patients MRI decisions and CT decisions respectively were false positive/false negative/correct in 2/4/15 respectively 0/8/13 cases. Correct diagnoses were obtained in 72% (MRI) respectively 62% (CT). In the subgroup of 12 cases including HRCT, MRI respectively CT were false positive/false negative/correct in 2/1/9 respectively 0/5/7 cases. Correct diagnoses were obtained in 75% (MRI) respectively 58% (CT). Conclusion: Highfield MRI of the lung is feasible and performed slightly better compared to CT in the

  4. Noninvasive in vivo tracking of mesenchymal stem cells and evaluation of cell therapeutic effects in a murine model using a clinical 3.0 T MRI.

    Science.gov (United States)

    Drey, Florian; Choi, Yeong-Hoon; Neef, Klaus; Ewert, Birgit; Tenbrock, Arne; Treskes, Philipp; Bovenschulte, Henning; Liakopoulos, Oliver J; Brenkmann, Meike; Stamm, Christof; Wittwer, Thorsten; Wahlers, Thorsten

    2013-01-01

    Cardiac cell therapy with mesenchymal stem cells (MSCs) represents a promising treatment approach for end-stage heart failure. However, little is known about the underlying mechanisms and the fate of the transplanted cells. The objective of the presented work is to determine the feasibility of magnetic resonance imaging (MRI) and in vivo monitoring after transplantation into infarcted mouse hearts using a clinical 3.0 T MRI device. The labeling procedure of bone marrow-derived MSCs with micron-sized paramagnetic iron oxide particles (MPIOs) did not affect the viability of the cells and their cell type-defining properties when compared to unlabeled cells. Using a clinical 3.0 T MRI scanner equipped with a dedicated small animal solenoid coil, 10(5) labeled MSCs could be detected and localized in the mouse hearts for up to 4 weeks after intramyocardial transplantation. Weekly ECG-gated scans using T1-weighted sequences were performed, and left ventricular function was assessed. Histological analysis of hearts confirmed the survival of labeled MSCs in the target area up to 4 weeks after transplantation. In conclusion, in vivo tracking of labeled MSCs using a clinical 3.0 T MRI scanner is feasible. In combination with assessment of heart function, this technology allows the monitoring of the therapeutic efficacy of regenerative therapies in a small animal model.

  5. Barriers to participation in a phase II cardiac rehabilitation programme.

    Science.gov (United States)

    Mak, Y M W; Chan, W K; Yue, C S S

    2005-12-01

    To identify barriers to participation in a phase II cardiac rehabilitation programme and measures that may enhance participation. Prospective study. Regional hospital, Hong Kong. Cardiac patients recruited for a phase I cardiac rehabilitation programme from July 2002 to January 2003. Reasons for not participating in a phase II cardiac rehabilitation programme. Of the 193 patients recruited for a phase I cardiac rehabilitation programme, 152 (79%) patients, with a mean age of 70.3 years (standard deviation, 11.9 years), did not proceed to phase II programme. Eleven (7%) deaths occurred before commencement of phase II and 74 (49%) patients were considered physically unfit. Reasons for the latter included fractures, pain, or degenerative changes in the lower limbs (24%), and co-morbidities such as cerebrovascular accident (19%), chronic renal failure (11%), congestive heart failure (9%), and unstable angina (8%). Phase II rehabilitation was postponed until after completion of scheduled cardiac interventions in 13% of patients. Failure of physicians to arrange the pre-phase II exercise stress test as per protocol was reported in 7% of patients. Other reasons were reported: work or time conflicts (16%), non-compliance with cardiac treatment (5%), financial constraints (4%), self-exercise (3%), fear after exercise stress testing (3%), and patients returning to their original cardiologists for treatment (3%). A significant (79%) proportion of patients did not proceed to a phase II cardiac rehabilitation programme for a variety of reasons. These included physical unfitness, work or time conflicts, and need to attend scheduled cardiac interventions. Further studies are required to determine how to overcome obstacles to cardiac rehabilitation.

  6. Coronary microembolization with normal epicardial coronary arteries and no visible infarcts on nitrobluetetrazolium chloride-stained specimens: Evaluation with cardiac magnetic resonance imaging in a swine model

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Hang; Yun, Hong; Zeng, Meng Su [Dept. of Radiology, Zhongshan Hospital, Fudan University and Shanghai Institute of Medical Imaging, Shanghai (China); Ma, Jian Ying; Chen, Zhang Wei; Chang, Shu Fu [Dept. of Cardiology, Zhongshan Hospital, Fudan University and Shanghai Institute of Cardiovascular Diseases, Shanghai (China)

    2016-02-15

    To assess magnetic resonance imaging (MRI) features of coronary microembolization in a swine model induced by small-sized microemboli, which may cause microinfarcts invisible to the naked eye. Eleven pigs underwent intracoronary injection of small-sized microspheres (42 µm) and catheter coronary angiography was obtained before and after microembolization. Cardiac MRI and measurement of cardiac troponin T (cTnT) were performed at baseline, 6 hours, and 1 week after microembolization. Postmortem evaluation was performed after completion of the imaging studies. Coronary angiography pre- and post-microembolization revealed normal epicardial coronary arteries. Systolic wall thickening of the microembolized regions decreased significantly from 42.6 ± 2.0% at baseline to 20.3 ± 2.3% at 6 hours and 31.5 ± 2.1% at 1 week after coronary microembolization (p < 0.001 for both). First-pass perfusion defect was visualized at 6 hours but the extent was largely decreased at 1 week. Delayed contrast enhancement MRI (DE-MRI) demonstrated hyperenhancement within the target area at 6 hours but not at 1 week. The microinfarcts on gross specimen stained with nitrobluetetrazolium chloride were invisible to the naked eye and only detectable microscopically. Increased cTnT was observed at 6 hours and 1 week after microembolization. Coronary microembolization induced by a certain load of small-sized microemboli may result in microinfarcts invisible to the naked eye with normal epicardial coronary arteries. MRI features of myocardial impairment secondary to such microembolization include the decline in left ventricular function and myocardial perfusion at cine and first-pass perfusion imaging, and transient hyperenhancement at DE-MRI.

  7. Cardiac imaging: working towards fully-automated machine analysis & interpretation.

    Science.gov (United States)

    Slomka, Piotr J; Dey, Damini; Sitek, Arkadiusz; Motwani, Manish; Berman, Daniel S; Germano, Guido

    2017-03-01

    Non-invasive imaging plays a critical role in managing patients with cardiovascular disease. Although subjective visual interpretation remains the clinical mainstay, quantitative analysis facilitates objective, evidence-based management, and advances in clinical research. This has driven developments in computing and software tools aimed at achieving fully automated image processing and quantitative analysis. In parallel, machine learning techniques have been used to rapidly integrate large amounts of clinical and quantitative imaging data to provide highly personalized individual patient-based conclusions. Areas covered: This review summarizes recent advances in automated quantitative imaging in cardiology and describes the latest techniques which incorporate machine learning principles. The review focuses on the cardiac imaging techniques which are in wide clinical use. It also discusses key issues and obstacles for these tools to become utilized in mainstream clinical practice. Expert commentary: Fully-automated processing and high-level computer interpretation of cardiac imaging are becoming a reality. Application of machine learning to the vast amounts of quantitative data generated per scan and integration with clinical data also facilitates a move to more patient-specific interpretation. These developments are unlikely to replace interpreting physicians but will provide them with highly accurate tools to detect disease, risk-stratify, and optimize patient-specific treatment. However, with each technological advance, we move further from human dependence and closer to fully-automated machine interpretation.

  8. Robotic cardiac surgery: an anaesthetic challenge.

    Science.gov (United States)

    Wang, Gang; Gao, Changqing

    2014-08-01

    Robotic cardiac surgery with the da Vinci robotic surgical system offers the benefits of a minimally invasive procedure, including a smaller incision and scar, reduced risk of infection, less pain and trauma, less bleeding and blood transfusion requirements, shorter hospital stay and decreased recovery time. Robotic cardiac surgery includes extracardiac and intracardiac procedures. Extracardiac procedures are often performed on a beating heart. Intracardiac procedures require the aid of peripheral cardiopulmonary bypass via a minithoracotomy. Robotic cardiac surgery, however, poses challenges to the anaesthetist, as the obligatory one-lung ventilation (OLV) and CO2 insufflation may reduce cardiac output and increase pulmonary vascular resistance, potentially resulting in hypoxaemia and haemodynamic compromise. In addition, surgery requires appropriate positioning of specialised cannulae such as an endopulmonary vent, endocoronary sinus catheter, and endoaortic clamp catheter under the guidance of transoesophageal echocardiography. Therefore, cardiac anaesthetists should have a working knowledge of these systems, OLV and haemodynamic support. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  9. Mathematical Models of Cardiac Pacemaking Function

    Directory of Open Access Journals (Sweden)

    Pan eLi

    2013-10-01

    Full Text Available Over the past half century, there has been intense and fruitful interaction between experimental and computational investigations of cardiac function. This interaction has, for example, led to deep understanding of cardiac excitation-contraction coupling; how it works, as well as how it fails. However, many lines of inquiry remain unresolved, among them the initiation of each heartbeat. The sinoatrial node, a cluster of specialized pacemaking cells in the right atrium of the heart, spontaneously generates an electro-chemical wave that spreads through the atria and through the cardiac conduction system to the ventricles, initiating the contraction of cardiac muscle essential for pumping blood to the body. Despite the fundamental importance of this primary pacemaker, this process is still not fully understood, and ionic mechanisms underlying cardiac pacemaking function are currently under heated debate. Several mathematical models of sinoatrial node cell membrane electrophysiology have been constructed as based on different experimental data sets and hypotheses. As could be expected, these differing models offer diverse predictions about cardiac pacemaking activities. This paper aims to present the current state of debate over the origins of the pacemaking function of the sinoatrial node. Here, we will specifically review the state-of-the-art of cardiac pacemaker modeling, with a special emphasis on current discrepancies, limitations, and future challenges.

  10. Stanford type A aortic dissection with closed false lumen: Analysis of prognostic factors at initial CT or MRI

    Energy Technology Data Exchange (ETDEWEB)

    Matsuoka, Yohjiro; Sakamoto, Ichiro; Ogawa, Yohji; Sueyoshi, Eijun; Hayashi, Kuniaki; Takagi, Masatake [Nagasaki Univ. (Japan). School of Medicine; Narimatsu, Motoharu

    1997-08-01

    Nineteen patients with Stanford type A acute aortic dissection with closed false lumen were reviewed. In the follow-up examinations, ulcerlike projection (ULP) in the ascending aorta (AA) or aortic arch (AR) was identified in 8 of 19 patients. In 5 of these 8 patients, acute cardiac tamponade occurred and 3 of them died. In the other 11 patients, there was no mortality, and only one patient underwent elective surgery. The appearance of ULP in the AA/AR is considered an indication for urgent surgery because it is regarded as a precursor of lethal complications such as cardiac tamponade. The purpose of this study was to investigate predictors of the appearance of ULP in the AA/AR with early imagings (CT or MRI) before the appearance of ULP. The patients were divided into two groups: patients with ULP in the AA/AR (8 patients) and others (11 patients). Initial CT or MRI findings of the thoracic aorta were retrospectively statistically analyzed in each group. Three predictive factors were statistically significant for the appearance of ULP in the AA/AR (diameter of the AA{>=}5 cm, thickness of the false lumen of the AA{>=}1 cm, thickness of the false lumen of the AA{>=} that of the descending aorta). Close attention should be paid, if any of these 3 factors is observed at initial CT or MRI. (author)

  11. Stanford type A aortic dissection with closed false lumen: Analysis of prognostic factors at initial CT or MRI

    International Nuclear Information System (INIS)

    Matsuoka, Yohjiro; Sakamoto, Ichiro; Ogawa, Yohji; Sueyoshi, Eijun; Hayashi, Kuniaki; Takagi, Masatake; Narimatsu, Motoharu.

    1997-01-01

    Nineteen patients with Stanford type A acute aortic dissection with closed false lumen were reviewed. In the follow-up examinations, ulcerlike projection (ULP) in the ascending aorta (AA) or aortic arch (AR) was identified in 8 of 19 patients. In 5 of these 8 patients, acute cardiac tamponade occurred and 3 of them died. In the other 11 patients, there was no mortality, and only one patient underwent elective surgery. The appearance of ULP in the AA/AR is considered an indication for urgent surgery because it is regarded as a precursor of lethal complications such as cardiac tamponade. The purpose of this study was to investigate predictors of the appearance of ULP in the AA/AR with early imagings (CT or MRI) before the appearance of ULP. The patients were divided into two groups: patients with ULP in the AA/AR (8 patients) and others (11 patients). Initial CT or MRI findings of the thoracic aorta were retrospectively statistically analyzed in each group. Three predictive factors were statistically significant for the appearance of ULP in the AA/AR (diameter of the AA≥5 cm, thickness of the false lumen of the AA≥1 cm, thickness of the false lumen of the AA≥ that of the descending aorta). Close attention should be paid, if any of these 3 factors is observed at initial CT or MRI. (author)

  12. Adaptive reconstructions for magnetic resonance imaging of moving organs

    International Nuclear Information System (INIS)

    Lohezic, Maelene

    2011-01-01

    Magnetic resonance imaging (MRI) is a valuable tool for the clinical diagnosis for brain imaging as well as cardiac and abdominal imaging. For instance, MRI is the only modality that enables the visualization and characterization myocardial edema. However, motion remains a challenging problem for cardiac MRI. Breathing as well as cardiac beating have to be carefully handled during patient examination. Moreover they limit the achievable temporal and spatial resolution of the images. In this work an approach that takes these physiological motions into account during image reconstruction process has been proposed. It allows performing cardiac examination while breathing freely. First, an iterative reconstruction algorithm, that compensates motion estimated from a motion model constrained by physiological signals, is applied to morphological cardiac imaging. A semi-automatic method for edema detection has been tested on reconstructed images. It has also been associated with an adaptive acquisition strategy which enables free-breathing end-systolic imaging. This reconstruction has then been extended to the assessment of transverse relaxation times T2, which is used for myocardial edema characterization. The proposed method, ARTEMIS, enables free-breathing T2 mapping without additional acquisition time. The proposed free breathing approaches take advantage of physiological signals to estimate the motion that occurs during MR acquisitions. Several solutions have been tested to measure this information. Among them, accelerometer-based external sensors allow local measurements at several locations. Another approach consists in the use of k-space based measurements, which are 'embedded' inside the MRI pulse sequence (navigator) and prevent from the requirement of additional recording hardware. Hence, several adaptive reconstruction algorithms were developed to obtain diagnostic information from free breathing acquisitions. These works allow performing efficient and accurate

  13. MRI for peripheral artery disease: Introductory physics for vascular physicians.

    Science.gov (United States)

    Roy, Trisha L; Forbes, Thomas L; Dueck, Andrew D; Wright, Graham A

    2018-04-01

    Magnetic resonance imaging (MRI) has advanced significantly in the past decade and provides a safe and non-invasive method of evaluating peripheral artery disease (PAD), with and without using exogenous contrast agents. MRI offers a promising alternative for imaging patients but the complexity of MRI can make it less accessible for physicians to understand or use. This article provides a brief introduction to the technical principles of MRI for physicians who manage PAD patients. We discuss the basic principles of how MRI works and tailor the discussion to how MRI can evaluate anatomic characteristics of peripheral arterial lesions.

  14. Cardiac magnetic resonance imaging in children

    International Nuclear Information System (INIS)

    Helbing, Willem A.; Ouhlous, Mohamed

    2015-01-01

    MRI is an important additional tool in the diagnostic work-up of children with congenital heart disease. This review aims to summarise the role MRI has in this patient population. Echocardiography remains the main diagnostic tool in congenital heart disease. In specific situations, MRI is used for anatomical imaging of congenital heart disease. This includes detailed assessment of intracardiac anatomy with 2-D and 3-D sequences. MRI is particularly useful for assessment of retrosternal structures in the heart and for imaging large vessel anatomy. Functional assessment includes assessment of ventricular function using 2-D cine techniques. Of particular interest in congenital heart disease is assessment of right and single ventricular function. Two-dimensional and newer 3-D techniques to quantify flow in these patients are or will soon become an integral part of quantification of shunt size, valve function and complex flow patterns in large vessels. More advanced uses of MRI include imaging of cardiovascular function during stress and tissue characterisation of the myocardium. Techniques used for this purpose need further validation before they can become part of the daily routine of MRI assessment of congenital heart disease. (orig.)

  15. MRI of the Chest

    Medline Plus

    Full Text Available ... metallic items, which can distort MRI images removable dental work pens, pocket knives and eyeglasses body piercings ... and send a signed report to your primary care or referring physician, who will share the results ...

  16. MRI of the Chest

    Medline Plus

    Full Text Available ... scanner. top of page How does the procedure work? Unlike conventional x-ray examinations and computed tomography ( ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ...

  17. MRI of the Chest

    Medline Plus

    Full Text Available ... and how it is working. MRI enables the discovery of abnormalities that might be obscured by bone ... Radiology (ACR) and the Radiological Society of North America (RSNA), comprising physicians with expertise in several radiologic ...

  18. Cell biology, MRI and geometry: insight into a microscopic/macroscopic marriage.

    Science.gov (United States)

    de Oliveira, Sérgio Almeida; Gowdak, Luís Henrique W; Buckberg, Gerald; Krieger, José Eduardo

    2006-04-01

    The concept of cell therapy as an adjunctive therapy to myocardial surgical revascularization for patients with severe coronary artery disease is illustrated by two case reports of ischemic cardiac disease that were unsuitable for revascularization by coronary grafting. The potential interaction of cell therapy, magnetic resonance imaging (MRI) of viability, and left ventricle (LV) restoration is described. Each patient had an ejection fraction below 30%, a relatively conical heart, and MRI gadolinium scan showing predominantly viable muscle. Intramyocardial injections of autologous bone marrow-derived cells (BMC) were performed along with either incomplete coronary artery bypass grafting (CABG) (to mother regions) or with transmyocardial laser revascularization (TMLR). An improvement in contractile function was seen at 6-12-month intervals after the procedure. The implications of possible underlying mechanisms of improvement in both myocardial perfusion and contractility suggest the striking importance of both micro- and macroenvironment for any cell-based therapeutic strategy. These observations imply that the interaction of cell biology, viability by MRI and geometry may be important in the future, as geometry can be restored surgically, and the new architectural form may develop enhanced function if it contains viable tissue and cell-based treatment can be delivered.

  19. Halogenated anaesthetics and cardiac protection in cardiac and non-cardiac anaesthesia

    Directory of Open Access Journals (Sweden)

    Landoni Giovanni

    2009-01-01

    Full Text Available Volatile anaesthetic agents have direct protective properties against ischemic myocardial damage. The implementation of these properties during clinical anaesthesia can provide an additional tool in the treatment or prevention, or both, of ischemic cardiac dysfunction in the perioperative period. A recent meta-analysis showed that desflurane and sevoflurane reduce postoperative mortality and incidence of myocardial infarction following cardiac surgery, with significant advantages in terms of postoperative cardiac troponin release, need for inotrope support, time on mechanical ventilation, intensive care unit and overall hospital stay. Multicentre, randomised clinical trials had previously demonstrated that the use of desflurane can reduce the postoperative release of cardiac troponin I, the need for inotropic support, and the number of patients requiring prolonged hospitalisation following coronary artery bypass graft surgery either with and without cardiopulmonary bypass. The American College of Cardiology/American Heart Association Guidelines recommend volatile anaesthetic agents during non-cardiac surgery for the maintenance of general anaesthesia in patients at risk for myocardial infarction. Nonetheless, e vidence in non-coronary surgical settings is contradictory and will be reviewed in this paper together with the mechanisms of cardiac protection by volatile agents.

  20. MRI findings in multifetal pregnancies complicated by twin reversed arterial perfusion sequence (TRAP)

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Carolina V.A.; Kline-Fath, Beth M.; Linam, Leann E.; Calvo Garcia, Maria A.; Rubio, Eva I. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Lim, Foong-Yen [Cincinnati Children' s Hospital Medical Center, Division of Pediatric Surgery, Cincinnati, OH (United States)

    2011-06-15

    Twin reversed arterial perfusion sequence (TRAP) is a rare complication in multifetal monochorionic pregnancies in which a normal ''pump'' twin provides circulation to an abnormal acardiac co-twin, resulting in high-output cardiac dysfunction in the pump twin. To define fetal MRI findings of TRAP sequence. Fetal MR images were retrospectively reviewed in 35 pregnancies complicated by TRAP sequence. Abnormalities of the pump twin, acardiac twin, umbilical cord, placenta and amniotic fluid were reviewed. Acardiac twins were classified as: acephalus (51%), anceps (40%), amorphus (9%), acormus (0%). Common findings in acardiac twins include subcutaneous edema (77%), absent cardiac structures (86%), absent or abnormal thoracic cavity (100%), abnormal abdominal organs (100%), superior limbs absent (46%) or abnormal (51%), and inferior limbs present but abnormal (83%). There were pump twin findings of cardiac dysfunction in 43% and intracranial ischemic changes in 3%. Umbilical cord anomalies were present in 97%. Acardiac twins present with a predictable pattern of malformation with poorly developed superior structures, more normally formed inferior structures and absent or rudimentary heart. Although usually absent, abnormal heart structures can be seen and do not exclude TRAP sequence. Pump twins are commonly normal with exception of findings of cardiac dysfunction and possible brain ischemia. (orig.)

  1. High performance MRI simulations of motion on multi-GPU systems.

    Science.gov (United States)

    Xanthis, Christos G; Venetis, Ioannis E; Aletras, Anthony H

    2014-07-04

    MRI physics simulators have been developed in the past for optimizing imaging protocols and for training purposes. However, these simulators have only addressed motion within a limited scope. The purpose of this study was the incorporation of realistic motion, such as cardiac motion, respiratory motion and flow, within MRI simulations in a high performance multi-GPU environment. Three different motion models were introduced in the Magnetic Resonance Imaging SIMULator (MRISIMUL) of this study: cardiac motion, respiratory motion and flow. Simulation of a simple Gradient Echo pulse sequence and a CINE pulse sequence on the corresponding anatomical model was performed. Myocardial tagging was also investigated. In pulse sequence design, software crushers were introduced to accommodate the long execution times in order to avoid spurious echoes formation. The displacement of the anatomical model isochromats was calculated within the Graphics Processing Unit (GPU) kernel for every timestep of the pulse sequence. Experiments that would allow simulation of custom anatomical and motion models were also performed. Last, simulations of motion with MRISIMUL on single-node and multi-node multi-GPU systems were examined. Gradient Echo and CINE images of the three motion models were produced and motion-related artifacts were demonstrated. The temporal evolution of the contractility of the heart was presented through the application of myocardial tagging. Better simulation performance and image quality were presented through the introduction of software crushers without the need to further increase the computational load and GPU resources. Last, MRISIMUL demonstrated an almost linear scalable performance with the increasing number of available GPU cards, in both single-node and multi-node multi-GPU computer systems. MRISIMUL is the first MR physics simulator to have implemented motion with a 3D large computational load on a single computer multi-GPU configuration. The incorporation

  2. Traction force microscopy of engineered cardiac tissues.

    Science.gov (United States)

    Pasqualini, Francesco Silvio; Agarwal, Ashutosh; O'Connor, Blakely Bussie; Liu, Qihan; Sheehy, Sean P; Parker, Kevin Kit

    2018-01-01

    Cardiac tissue development and pathology have been shown to depend sensitively on microenvironmental mechanical factors, such as extracellular matrix stiffness, in both in vivo and in vitro systems. We present a novel quantitative approach to assess cardiac structure and function by extending the classical traction force microscopy technique to tissue-level preparations. Using this system, we investigated the relationship between contractile proficiency and metabolism in neonate rat ventricular myocytes (NRVM) cultured on gels with stiffness mimicking soft immature (1 kPa), normal healthy (13 kPa), and stiff diseased (90 kPa) cardiac microenvironments. We found that tissues engineered on the softest gels generated the least amount of stress and had the smallest work output. Conversely, cardiomyocytes in tissues engineered on healthy- and disease-mimicking gels generated significantly higher stresses, with the maximal contractile work measured in NRVM engineered on gels of normal stiffness. Interestingly, although tissues on soft gels exhibited poor stress generation and work production, their basal metabolic respiration rate was significantly more elevated than in other groups, suggesting a highly ineffective coupling between energy production and contractile work output. Our novel platform can thus be utilized to quantitatively assess the mechanotransduction pathways that initiate tissue-level structural and functional remodeling in response to substrate stiffness.

  3. Teaching cardiac auscultation to trainees in internal medicine and family practice: Does it work?

    Science.gov (United States)

    Favrat, B; Pécoud, A; Jaussi, A

    2004-01-01

    Background The general proficiency in physical diagnostic skills seems to be declining in relation to the development of new technologies. The few studies that have examined this question have invariably used recordings of cardiac events obtained from patients. However, this type of evaluation may not correlate particularly well with bedside skills. Our objectives were 1) To compare the cardiac auscultatory skills of physicians in training with those of experienced cardiologists by using real patients to test bedside diagnostic skills. 2) To evaluate the impact of a five-month bedside cardiac auscultation training program. Methods 1) In an academic primary care center, 20 physicians (trainees in internal medicine and family practice) and two skilled academic cardiologists listened to 33 cardiac events in 13 patients directly at bedside and identified the cardiac events by completing an open questionnaire. Heart sounds, murmurs and diagnosis were determined beforehand by an independent skilled cardiologist and were validated by echocardiography. Thirteen primary cardiologic diagnoses were possible. 2) Ten of the physicians agreed to participate in a course of 45-minute sessions once a week for 5 months. After the course they listened again to the same patients (pre/post-interventional study). Results 1) The experts were the most skillful, achieving 69% recognition of heart sounds and murmurs and correct diagnoses in 62% of cases. They also heard all of the diastolic murmurs. The residents heard only 40% of the extra heart sounds and made a correct diagnosis in 24% of cases. 2) After the weekly training sessions, their mean percentage for correct diagnosis was 35% [an increase of 66% (p < 0.05)]. Conclusions The level of bedside diagnostic skills in this relatively small group of physicians in training is indeed low, but can be improved by a course focusing on realistic bedside teaching. PMID:15056393

  4. Review of radiation safety in the cardiac catheterization laboratory

    International Nuclear Information System (INIS)

    Johnson, L.W.; Moore, R.J.; Balter, S.

    1992-01-01

    With the increasing use of coronary arteriography and interventional procedures, radiation exposure to patients and personnel working in cardiac catheterization laboratories has increased. Proper technique to minimize both patient and operator exposure is necessary. A practical approach to radiation safety in the cardiac catheterization laboratory is presented. This discussion should be useful to facilities with well-established radiation safety programs as well as facilities that require restructuring to cope with the radiation environment in a modern cardiac catheterization laboratory

  5. MRI of the Chest

    Medline Plus

    Full Text Available ... procedure work? How is the procedure performed? What will I experience during and after the procedure? Who interprets the results and how do I get them? What are the benefits vs. risks? What are the limitations of MRI ...

  6. Turbulent Kinetic Energy Measurement Using Phase Contrast MRI for Estimating the Post-Stenotic Pressure Drop: In Vitro Validation and Clinical Application.

    Directory of Open Access Journals (Sweden)

    Hojin Ha

    Full Text Available Although the measurement of turbulence kinetic energy (TKE by using magnetic resonance imaging (MRI has been introduced as an alternative index for quantifying energy loss through the cardiac valve, experimental verification and clinical application of this parameter are still required.The goal of this study is to verify MRI measurements of TKE by using a phantom stenosis with particle image velocimetry (PIV as the reference standard. In addition, the feasibility of measuring TKE with MRI is explored.MRI measurements of TKE through a phantom stenosis was performed by using clinical 3T MRI scanner. The MRI measurements were verified experimentally by using PIV as the reference standard. In vivo application of MRI-driven TKE was explored in seven patients with aortic valve disease and one healthy volunteer. Transvalvular gradients measured by MRI and echocardiography were compared.MRI and PIV measurements of TKE are consistent for turbulent flow (0.666 400. The turbulence pressure drop correlates strongly with total TKE (R2 = 0.986. However, in vivo measurements of TKE are not consistent with the transvalvular pressure gradient estimated by echocardiography.These results suggest that TKE measurement via MRI may provide a potential benefit as an energy-loss index to characterize blood flow through the aortic valve. However, further clinical studies are necessary to reach definitive conclusions regarding this technique.

  7. Cardiac autonomic response following high-intensity running work-to-rest interval manipulation.

    Science.gov (United States)

    Cipryan, Lukas; Laursen, Paul B; Plews, Daniel J

    2016-10-01

    The cardiorespiratory, cardiac autonomic (via heart rate variability (HRV)) and plasma volume responses to varying sequences of high-intensity interval training (HIT) of consistent external work were investigated. Twelve moderately trained males underwent three HIT bouts and one control session. The HIT trials consisted of warm-up, followed by 12 min of 15 s, 30 s or 60 s work:relief HIT sequences at an exercise intensity of 100% of the individual velocity at [Formula: see text]O2max (v[Formula: see text]O2max), interspersed by relief intervals at 60% [Formula: see text]O2max (work/relief ratio = 1). HRV was evaluated via the square root of the mean sum of the squared differences between R-R intervals (rMSSD) before, 1 h, 3 h and 24 h after the exercise. Plasma volume was assessed before, immediately after, and 3 h and 24 h after. There were no substantial between-trial differences in acute cardiorespiratory responses. The rMSSD values remained decreased 1 h after the exercise cessation in all exercise groups. The rMSSD subsequently increased between 1 h and 3 h after exercise, with the most pronounced change in the 15/15 group. There were no relationships between HRV and plasma volume. All HIT protocols resulted in similar cardiorespiratory responses with slightly varying post-exercise HRV responses, with the 30/30 protocol eliciting the least disruption to post-exercise HRV. These post-exercise HRV findings suggest that the 30/30 sequence may be the preferable HIT prescription when the between-training period is limited.

  8. Left Ventricle: Fully Automated Segmentation Based on Spatiotemporal Continuity and Myocardium Information in Cine Cardiac Magnetic Resonance Imaging (LV-FAST

    Directory of Open Access Journals (Sweden)

    Lijia Wang

    2015-01-01

    Full Text Available CMR quantification of LV chamber volumes typically and manually defines the basal-most LV, which adds processing time and user-dependence. This study developed an LV segmentation method that is fully automated based on the spatiotemporal continuity of the LV (LV-FAST. An iteratively decreasing threshold region growing approach was used first from the midventricle to the apex, until the LV area and shape discontinued, and then from midventricle to the base, until less than 50% of the myocardium circumference was observable. Region growth was constrained by LV spatiotemporal continuity to improve robustness of apical and basal segmentations. The LV-FAST method was compared with manual tracing on cardiac cine MRI data of 45 consecutive patients. Of the 45 patients, LV-FAST and manual selection identified the same apical slices at both ED and ES and the same basal slices at both ED and ES in 38, 38, 38, and 41 cases, respectively, and their measurements agreed within -1.6±8.7 mL, -1.4±7.8 mL, and 1.0±5.8% for EDV, ESV, and EF, respectively. LV-FAST allowed LV volume-time course quantitatively measured within 3 seconds on a standard desktop computer, which is fast and accurate for processing the cine volumetric cardiac MRI data, and enables LV filling course quantification over the cardiac cycle.

  9. Cardiac fusion and complex congenital cardiac defects in thoracopagus twins: diagnostic value of cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of); Park, Jeong-Jun [University of Ulsan College of Medicine, Asan Medical Center, Department of Pediatric Cardiac Surgery, Seoul (Korea, Republic of); Kim, Ellen Ai-Rhan [University of Ulsan College of Medicine, Asan Medical Center, Division of Neonatology, Department of Pediatrics, Seoul (Korea, Republic of); Won, Hye-Sung [University of Ulsan College of Medicine, Asan Medical Center, Department of Obstetrics and Gynecology, Seoul (Korea, Republic of)

    2014-09-15

    Most thoracopagus twins present with cardiac fusion and associated congenital cardiac defects, and assessment of this anatomy is of critical importance in determining patient care and outcome. Cardiac CT with electrocardiographic triggering provides an accurate and quick morphological assessment of both intracardiac and extracardiac structures in newborns, making it the best imaging modality to assess thoracopagus twins during the neonatal period. In this case report, we highlight the diagnostic value of cardiac CT in thoracopagus twins with an interatrial channel and complex congenital cardiac defects. (orig.)

  10. Three-dimensional magnetic resonance imaging overlay to assist with percutaneous transhepatic access at the time of cardiac catheterization

    International Nuclear Information System (INIS)

    Whiteside, Wendy; Christensen, Jason; Zampi, Jeffrey D

    2005-01-01

    Multimodality image overlay is increasingly used for complex interventional procedures in the cardiac catheterization lab. We report a case in which three-dimensional magnetic resonance imaging (3D MRI) overlay onto live fluoroscopic imaging was utilized to safely obtain transhepatic access in a 12-year-old patient with prune belly syndrome, complex and distorted abdominal anatomy, and a vascular mass within the liver

  11. Relation of Left Atrial Size, Cardiac Morphology, and Clinical Outcome in Asymptomatic Aortic Stenosis

    DEFF Research Database (Denmark)

    Christensen, Nicolaj Lyhne; Dahl, Jordi; Carter-Storch, Rasmus

    2017-01-01

    characterized by higher LV mass index (73 ± 17 g/m² vs. 66 ± 16 g/m² , p=0.03), increased right ventricle (70 ± 14 ml/m² vs. 63 ± 12 ml/m², p=0.01) and LV end-diastolic volume index (84 ± 18 ml/m² vs. 77 ± 16 ml/m², p=0.05), and higher brain natriuretic peptide (BNP). No difference in late enhancement was seen......Left atrial (LA) dilatation in asymptomatic severe aortic stenosis (AS) may be an indicator of advanced disease. The aim was to investigate the association between LA volume index (LAVi) and left ventricular (LV) morphology assessed with cardiac magnetic resonance imaging (cMRI), and to assess...... underwent echocardiography, cMRI, exercise test, and patients were followed for the composite endpoint of death, readmission or aortic valve replacement. AVA index was similar (0.45 ± 0.08 cm² /m² vs. 0.45 ± 0.09 cm², p=0.85) in patients with a dilated and normal LA. On cMRI patients with dilated LA were...

  12. MRI of the Chest

    Medline Plus

    Full Text Available ... to prepare your child for the sedation or anesthesia. Alternatively, certain pediatric facilities have child life personnel who can work with younger children to help avoid the need for sedation or anesthesia. They prepare the children for MRI by showing ...

  13. Imaging children suffering from lymphoma: an evaluation of different 18F-FDG PET/MRI protocols compared to whole-body DW-MRI.

    Science.gov (United States)

    Kirchner, Julian; Deuschl, Cornelius; Schweiger, Bernd; Herrmann, Ken; Forsting, Michael; Buchbender, Christian; Antoch, Gerald; Umutlu, Lale

    2017-09-01

    The objectives of this study were to evaluate and compare the diagnostic potential of different PET/MRI reading protocols, entailing non-enhanced / contrast-enhanced and diffusion-weighted 18 F-FDG PET/MR imaging and whole-body diffusion-weighted MRI for lesion detection and determination of the tumor stage in pediatric lymphoma patients. A total of 28 18 F-FDG PET/MRI datasets were included for analysis of four different reading protocols: (1) PET/MRI utilizing sole unenhanced T2w and T1w imaging, (2) PET/MRI utilizing additional contrast enhanced sequences, (3) PET/MR imaging utilizing unenhanced, contrast enhanced and DW imaging or (4) WB-DW-MRI. Statistical analyses were performed on a per-patient and a per-lesion basis. Follow-up and prior examinations as well as histopathology served as reference standards. PET/MRI correctly identified all 17 examinations with active lymphoma disease, while WB-DW-MRI correctly identified 15/17 examinations. Sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy were 96%, 96.5%, 97%, 95%, and 96% for PET/MRI 1 ; 97%, 96.5%, 97%, 96.5%, and 97% for PET/MRI 2 ; 97%, 96.5%, 97%, 96.5%, and 97% for PET/MRI 3 and 77%, 96%, 96%, 78.5% and 86% for MRI-DWI. 18 F-FDG PET/MRI is superior to WB-DW-MRI in staging pediatric lymphoma patients. Neither application of contrast media nor DWI leads to a noticeable improvement of the diagnostic accuracy of PET/MRI. Thus, unenhanced PET/MRI may play a crucial role for the diagnostic work-up of pediatric lymphoma patients in the future.

  14. Physiological denoising of BOLD fMRI data using Regressor Interpolation at Progressive Time Delays (RIPTiDe) processing of concurrent fMRI and near-infrared spectroscopy (NIRS).

    Science.gov (United States)

    Frederick, Blaise deB; Nickerson, Lisa D; Tong, Yunjie

    2012-04-15

    Confounding noise in BOLD fMRI data arises primarily from fluctuations in blood flow and oxygenation due to cardiac and respiratory effects, spontaneous low frequency oscillations (LFO) in arterial pressure, and non-task related neural activity. Cardiac noise is particularly problematic, as the low sampling frequency of BOLD fMRI ensures that these effects are aliased in recorded data. Various methods have been proposed to estimate the noise signal through measurement and transformation of the cardiac and respiratory waveforms (e.g. RETROICOR and respiration volume per time (RVT)) and model-free estimation of noise variance through examination of spatial and temporal patterns. We have previously demonstrated that by applying a voxel-specific time delay to concurrently acquired near infrared spectroscopy (NIRS) data, we can generate regressors that reflect systemic blood flow and oxygenation fluctuations effects. Here, we apply this method to the task of removing physiological noise from BOLD data. We compare the efficacy of noise removal using various sets of noise regressors generated from NIRS data, and also compare the noise removal to RETROICOR+RVT. We compare the results of resting state analyses using the original and noise filtered data, and we evaluate the bias for the different noise filtration methods by computing null distributions from the resting data and comparing them with the expected theoretical distributions. Using the best set of processing choices, six NIRS-generated regressors with voxel-specific time delays explain a median of 10.5% of the variance throughout the brain, with the highest reductions being seen in gray matter. By comparison, the nine RETROICOR+RVT regressors together explain a median of 6.8% of the variance in the BOLD data. Detection of resting state networks was enhanced with NIRS denoising, and there were no appreciable differences in the bias of the different techniques. Physiological noise regressors generated using

  15. WE-B-BRD-00: MRI for Radiation Oncology

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-06-15

    The use of MRI in radiation therapy is rapidly increasing. Applications vary from the MRI simulator, to the MRI fused with CT, and to the integrated MRI+RT system. Compared with the standard MRI QA, a broader scope of QA features has to be defined in order to maximize the benefits of using MRI in radiation therapy. These QA features include geometric fidelity, image registration, motion management, cross-system alignment, and hardware interference. Advanced MRI techniques require a specific type of QA, as they are being widely used in radiation therapy planning, dose calculations, post-implant dosimetry, and prognoses. A vigorous and adaptive QA program is crucial to defining the responsibility of the entire radiation therapy group and detecting deviations from the performance of high-quality treatment. As a drastic departure from CT simulation, MRI simulation requires changes in the work flow of treatment planning and image guidance. MRI guided radiotherapy platforms are being developed and commercialized to take the advantage of the advance in knowledge, technology and clinical experience. This symposium will from an educational perspective discuss the scope and specific issues related to MRI guided radiotherapy. Learning Objectives: Understand the difference between a standard and a radiotherapy-specific MRI QA program. Understand the effects of MRI artifacts (geometric distortion and motion) on radiotherapy. Understand advanced MRI techniques (ultrashort echo, fast MRI including dynamic MRI and 4DMRI, diffusion, perfusion, and MRS) and related QA. Understand the methods to prepare MRI for treatment planning (electron density assignment, multimodality image registration, segmentation and motion management). Current status of MRI guided treatment platforms. Dr. Jihong Wang has a research grant with Elekta-MRL project. Dr. Ke Sheng receives research grants from Varian Medical systems.

  16. Evaluation of respiratory and cardiac motion correction schemes in dual gated PET/CT cardiac imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lamare, F., E-mail: frederic.lamare@chu-bordeaux.fr; Fernandez, P. [Univ. Bordeaux, INCIA, UMR 5287, F-33400 Talence (France); CNRS, INCIA, UMR 5287, F-33400 Talence (France); Service de Médecine Nucléaire, Hôpital Pellegrin, CHU de Bordeaux, 33076 Bordeaux (France); Le Maitre, A.; Visvikis, D. [INSERM, UMR1101, LaTIM, Université de Bretagne Occidentale, 29609 Brest (France); Dawood, M.; Schäfers, K. P. [European Institute for Molecular Imaging, University of Münster, Mendelstr. 11, 48149 Münster (Germany); Rimoldi, O. E. [Vita-Salute University and Scientific Institute San Raffaele, Milan, Italy and CNR Istituto di Bioimmagini e Fisiologia Molecolare, Milan (Italy)

    2014-07-15

    Purpose: Cardiac imaging suffers from both respiratory and cardiac motion. One of the proposed solutions involves double gated acquisitions. Although such an approach may lead to both respiratory and cardiac motion compensation there are issues associated with (a) the combination of data from cardiac and respiratory motion bins, and (b) poor statistical quality images as a result of using only part of the acquired data. The main objective of this work was to evaluate different schemes of combining binned data in order to identify the best strategy to reconstruct motion free cardiac images from dual gated positron emission tomography (PET) acquisitions. Methods: A digital phantom study as well as seven human studies were used in this evaluation. PET data were acquired in list mode (LM). A real-time position management system and an electrocardiogram device were used to provide the respiratory and cardiac motion triggers registered within the LM file. Acquired data were subsequently binned considering four and six cardiac gates, or the diastole only in combination with eight respiratory amplitude gates. PET images were corrected for attenuation, but no randoms nor scatter corrections were included. Reconstructed images from each of the bins considered above were subsequently used in combination with an affine or an elastic registration algorithm to derive transformation parameters allowing the combination of all acquired data in a particular position in the cardiac and respiratory cycles. Images were assessed in terms of signal-to-noise ratio (SNR), contrast, image profile, coefficient-of-variation (COV), and relative difference of the recovered activity concentration. Results: Regardless of the considered motion compensation strategy, the nonrigid motion model performed better than the affine model, leading to higher SNR and contrast combined with a lower COV. Nevertheless, when compensating for respiration only, no statistically significant differences were

  17. Partially Adaptive STAP Algorithm Approaches to functional MRI

    Science.gov (United States)

    Huang, Lejian; Thompson, Elizabeth A.; Schmithorst, Vincent; Holland, Scott K.; Talavage, Thomas M.

    2010-01-01

    In this work, the architectures of three partially adaptive STAP algorithms are introduced, one of which is explored in detail, that reduce dimensionality and improve tractability over fully adaptive STAP when used in construction of brain activation maps in fMRI. Computer simulations incorporating actual MRI noise and human data analysis indicate that element space partially adaptive STAP can attain close to the performance of fully adaptive STAP while significantly decreasing processing time and maximum memory requirements, and thus demonstrates potential in fMRI analysis. PMID:19272913

  18. Clinical recommendations of cardiac magnetic resonance, Part II: inflammatory and congenital heart disease, cardiomyopathies and cardiac tumors: a position paper of the working group 'Applicazioni della Risonanza Magnetica' of the Italian Society of Cardiology.

    Science.gov (United States)

    Pontone, Gianluca; Di Bella, Gianluca; Silvia, Castelletti; Maestrini, Viviana; Festa, Pierluigi; Ait-Ali, Lamia; Masci, Pier Giorgio; Monti, Lorenzo; di Giovine, Gabriella; De Lazzari, Manuel; Cipriani, Alberto; Guaricci, Andrea I; Dellegrottaglie, Santo; Pepe, Alessia; Marra, Martina Perazzolo; Aquaro, Giovanni D

    2017-04-01

    The current document was developed by the working group on the 'application of cardiac magnetic resonance' of the Italian Society of Cardiology to provide a perspective on the current state of technical advances and clinical cardiac magnetic resonance applications and to inform cardiologists how to implement their clinical and diagnostic pathway with the introduction of this technique in the clinical practice. Appropriateness criteria were defined using a score system: score 1-3 = inappropriate (test is not generally acceptable and is not a reasonable approach for the indication), score 4-6 = uncertain (test may be generally acceptable and may be a reasonable approach for the indication but more research and/or patient information is needed to classify the indication definitively) and score 7-9 = appropriate (test is generally acceptable and is a reasonable approach for the indication).

  19. Clinical utility of (18)F-FDG positron emission tomography/computed tomography scan vs. (99m)Tc-HMPAO white blood cell single-photon emission computed tomography in extra-cardiac work-up of infective endocarditis

    DEFF Research Database (Denmark)

    Lauridsen, Trine K; Iversen, Kasper K; Ihlemann, Nikolaj

    2017-01-01

    The extra-cardiac work-up in infective endocarditis (IE) comprises a search for primary and secondary infective foci. Whether18FDG-PET/CT or WBC-SPECT/CT is superior in detection of clinically relevant extra-cardiac manifestations in IE is unexplored. The objectives of this study were to identify...

  20. Three-dimensional maximum principal strain using cardiac computed tomography for identification of myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Tanabe, Yuki; Kido, Teruhito; Kurata, Akira; Sawada, Shun; Suekuni, Hiroshi; Kido, Tomoyuki; Yokoi, Takahiro; Miyagawa, Masao; Mochizuki, Teruhito [Ehime University Graduate School of Medicine, Department of Radiology, Toon City, Ehime (Japan); Uetani, Teruyoshi; Inoue, Katsuji [Ehime University Graduate School of Medicine, Department of Cardiology, Pulmonology, Hypertension and Nephrology, Toon City, Ehime (Japan)

    2017-04-15

    To evaluate the feasibility of three-dimensional (3D) maximum principal strain (MP-strain) derived from cardiac computed tomography (CT) for detecting myocardial infarction (MI). Forty-three patients who underwent cardiac CT and magnetic resonance imaging (MRI) were retrospectively selected. Using the voxel tracking of motion coherence algorithm, the peak CT MP-strain was measured using the 16-segment model. With the trans-mural extent of late gadolinium enhancement (LGE) and the distance from MI, all segments were classified into four groups (infarcted, border, adjacent, and remote segments); infarcted and border segments were defined as MI with LGE positive. Diagnostic performance of MP-strain for detecting MI was compared with per cent systolic wall thickening (%SWT) assessed by MRI using receiver-operating characteristic curve analysis at a segment level. Of 672 segments excluding16 segments influenced by artefacts, 193 were diagnosed as MI. Sensitivity and specificity of peak MP-strain to identify MI were 81 % [95 % confidence interval (95 % CI): 74-88 %] and 86 % (81-92 %) compared with %SWT: 76 % (60-95 %) and 68 % (48-84 %), respectively. The area under the curve of peak MP-strain was superior to %SWT [0.90 (0.87-0.93) vs. 0.80 (0.76-0.83), p < 0.05]. CT MP-strain has a potential to provide incremental value to coronary CT angiography for detecting MI. (orig.)