WorldWideScience

Sample records for cardiac iodine-123 metaiodobenzylguanidine

  1. Iodine-123 metaiodobenzylguanidine imaging of the heart in idiopathic congestive cardiomyopathy and cardiac transplants

    International Nuclear Information System (INIS)

    Glowniak, J.V.; Turner, F.E.; Gray, L.L.; Palac, R.T.; Lagunas-Solar, M.C.; Woodward, W.R.

    1989-01-01

    Iodine-123 metaiodobenzylguanidine ([ 123 I]MIBG) is a norepinephrine analog which can be used to image the sympathetic innervation of the heart. In this study, cardiac imaging with [ 123 I]MIBG was performed in patients with idiopathic congestive cardiomyopathy and compared to normal controls. Initial uptake, half-time of tracer within the heart, and heart to lung ratios were all significantly reduced in patients compared to normals. Uptake in lungs, liver, salivary glands, and spleen was similar in controls and patients with cardiomyopathy indicating that decreased MIBG uptake was not a generalized abnormality in these patients. Iodine-123 MIBG imaging was also performed in cardiac transplant patients to determine cardiac nonneuronal uptake. Uptake in transplants was less than 10% of normals in the first 2 hr and nearly undetectable after 16 hr. The decreased uptake of MIBG suggests cardiac sympathetic nerve dysfunction while the rapid washout of MIBG from the heart suggests increased cardiac sympathetic nerve activity in idiopathic congestive cardiomyopathy

  2. Cardiac iodine-123 metaiodobenzylguanidine uptake in animals with diabetes mellitus and/or hypertension

    International Nuclear Information System (INIS)

    Dubois, E.A.; Kam, K.L.; Somsen, G.A.; Boer, G.J.; Bruin, K. de; Batink, H.D.; Pfaffendorf, M.; Royen, E.A. van; Zwieten, P.A. van

    1996-01-01

    The aim of the present study was to evaluate the use of the noradrenaline analogue iodine-123 metaiodobenzylguanidine ([ 123 I]MIBG) for the assessment of cardiac sympathetic activity in the presence of diabetes mellitus and/or hypertension in animal models. One model used Wistar-Kyoto rats (WKY) and spontaneously hypertensive rats (SHR) rendered diabetic at 12 weeks of age by an intravenous injection of streptozotocin (STZ). The other model used lean and obese Zucker rats. In all groups basic haemodynamic values were established and animals received an intravenous injection of 50 μCi [ 123 I]MIBG. Initial myocardial uptake and washout rates of [ 123 I]MIBG were measured scintigraphically during 4 h. After sacrifice, plasma noradrenaline and left cardiac ventricular β-adrenoceptor density was determined. The diabetic state, both in STZ-treated rats (direct induction) and in obese Zucker rats (genetic induction), appeared to induce a lower cardiac density of β-adrenoceptors, indicative of increased sympathetic activity. Cardiac [ 123 I]MIBG then showed increased washouts, thereby confirming enhanced noradrenergic activity. This parallism of results led to the conclusion that [ 123 I]MIBG wash-out measurements could provide an excellent tool to assess cardiac sympathetic activity noninvasively. However, in hypertension (WKY vs SHR), both parameters failed to show parallelism: no changes in β-adrenoceptor density were found, whereas [ 123 I]MIBG wash-out rate was increased. Thus, either [ 123 I]MIBG washout or β-adrenoceptor density may not be a reliable parameter under all circumstances to detect changes in the release of noradrenaline. (orig./MG)

  3. Assessment of cardiac sympathetic nerve activity in children with chronic heart failure using quantitative iodine-123 metaiodobenzylguanidine imaging

    Energy Technology Data Exchange (ETDEWEB)

    Karasawa, Kensuke; Ayusawa, Mamoru; Noto, Nobutaka; Sumitomo, Naokata; Okada, Tomoo; Harada, Kensuke [Nihon Univ., Tokyo (Japan). School of Medicine

    2000-12-01

    Cardiac sympathetic nerve activity in children with chronic heart failure was examined by quantitative iodine-123 metaiodobenzylguanidine (MIBG) myocardial imaging in 33 patients aged 7.5{+-}6.1 years (range 0-18 years), including 8 with cardiomyopathy, 15 with congenital heart disease, 3 with anthracycrine cardiotoxicity, 3 with myocarditis, 3 with primary pulmonary hypertension and 1 with Pompe's disease. Anterior planar images were obtained 15 min and 3 hr after the injection of iodine-123 MIBG. The cardiac iodine-123 MIBG uptake was assessed as the heart to upper mediastinum uptake activity ratio of the delayed image (H/M) and the cardiac percentage washout rate (%WR). The severity of chronic heart failure was class I (no medication) in 8 patients, class II (no symptom with medication) in 9, class III (symptom even with medication) in 10 and class IV (late cardiac death) in 6. H/M was 2.33{+-}0.22 in chronic heart failure class I, 2.50{+-}0.34 in class II, 1.95{+-}0.61 in class III, and 1.39{+-}0.29 in class IV (p<0.05). %WR was 24.8{+-}12.8% in chronic heart failure class I, 23.3{+-}10.2% in class II, 49.2{+-}24.5% in class III, and 66.3{+-}26.5% in class IV (p<0.05). The low H/M and high %WR were proportionate to the severity of chronic heart failure. Cardiac iodine-123 MIBG showed cardiac adrenergic neuronal dysfunction in children with severe chronic heart failure. Quantitative iodine-123 MIBG myocardial imaging is clinically useful as a predictor of therapeutic outcome and mortality in children with chronic heart failure. (author)

  4. Assessment of cardiac sympathetic nerve activity in children with chronic heart failure using quantitative iodine-123 metaiodobenzylguanidine imaging

    International Nuclear Information System (INIS)

    Karasawa, Kensuke; Ayusawa, Mamoru; Noto, Nobutaka; Sumitomo, Naokata; Okada, Tomoo; Harada, Kensuke

    2000-01-01

    Cardiac sympathetic nerve activity in children with chronic heart failure was examined by quantitative iodine-123 metaiodobenzylguanidine (MIBG) myocardial imaging in 33 patients aged 7.5±6.1 years (range 0-18 years), including 8 with cardiomyopathy, 15 with congenital heart disease, 3 with anthracycrine cardiotoxicity, 3 with myocarditis, 3 with primary pulmonary hypertension and 1 with Pompe's disease. Anterior planar images were obtained 15 min and 3 hr after the injection of iodine-123 MIBG. The cardiac iodine-123 MIBG uptake was assessed as the heart to upper mediastinum uptake activity ratio of the delayed image (H/M) and the cardiac percentage washout rate (%WR). The severity of chronic heart failure was class I (no medication) in 8 patients, class II (no symptom with medication) in 9, class III (symptom even with medication) in 10 and class IV (late cardiac death) in 6. H/M was 2.33±0.22 in chronic heart failure class I, 2.50±0.34 in class II, 1.95±0.61 in class III, and 1.39±0.29 in class IV (p<0.05). %WR was 24.8±12.8% in chronic heart failure class I, 23.3±10.2% in class II, 49.2±24.5% in class III, and 66.3±26.5% in class IV (p<0.05). The low H/M and high %WR were proportionate to the severity of chronic heart failure. Cardiac iodine-123 MIBG showed cardiac adrenergic neuronal dysfunction in children with severe chronic heart failure. Quantitative iodine-123 MIBG myocardial imaging is clinically useful as a predictor of therapeutic outcome and mortality in children with chronic heart failure. (author)

  5. Cardiac Iodine-123 metaiodobenzylguanidine (123I-MIBG) scintigraphy parameter predicts cardiac and cerebrovascular events in type 2 diabetic patients without structural heart disease

    International Nuclear Information System (INIS)

    Yufu, Kunio; Takahashi, Naohiko; Okada, Norihiro; Shinohara, Tetsuji; Nakagawa, Mikiko; Hara, Masahide; Yoshimatsu, Hironobu; Saikawa, Tetsunori

    2012-01-01

    Cardiac iodine-123 metaiodobenzylguanidine ( 123 I-MIBG) scintigraphy is an established method of assessment of cardiovascular sympathetic function. The aim of the present study was to investigate the long-term cardiovascular predictive value of cardiac 123 I-MIBG scintigraphy parameters in Japanese type 2 diabetic patients without structural heart disease. Cardiac 123 I-MIBG scintigraphy in 108 patients with type 2 diabetes who did not have structural heart disease, was evaluated. The washout rate (WR) was considered enhanced if it was ≥40%. Accurate follow-up information for 4.6 years was obtained in 54 enhanced WR patients (27 male; mean age, 61±11 years) and in 54 sex- and age-matched preserved WR patients (27 male; mean age, 61±10 years). Major adverse cardiac and cerebrovascular events (MACCE) were investigated. During follow-up, 10 enhanced WR patients developed MACCE including cardiac death, coronary revascularization, stroke, and congestive heart failure, while MACCE occurred in only 3 male patients. The Kaplan-Meier curves indicated that enhanced WR patients had higher incidence of MACCE than those with preserved WR (P 123 I-MIBG scintigraphy at baseline has long-term cardiovascular predictive value in Japanese patients with type 2 diabetes without structural heart disease. (author)

  6. Iodine-123 metaiodobenzylguanidine in the assessment of late cardiac effects from cancer therapy

    International Nuclear Information System (INIS)

    Valdes Olmos, R.A.; Bokkel Huinink, W.W. ten; Dewit, L.G.H.; Hoefnagel, C.A.; Liem, I.H.; Tinteren, H. van

    1996-01-01

    Recognition of adverse late cardiac effects from cancer therapy may enable identification of patients with risk of cardiotoxicity upon cancer retreatment. In this study the feasibility of using iodine-123 metaiodobenzylguanidine ( 123 I-MIBG) heart scintigraphy to detect abnormalities of the myocardial adrenergic neurone function in the late period after cancer therapy was evaluated in relation to the left ventricle ejection fraction (LVEF) in 18 cancer patients: 11 had undergone thoracic irradiation involving the heart, in five cases in combination with anthracycline therapy, 11-228 months (median 60 months) before radionuclide tests, while seven had not received previous anthracycline and/or radiotherapy (controls). The 123 I-MIBG cardiac uptake, expressed as a heart-to-mediastinum ratio on planar images after 4 h, ranged from 1.21 to 1.76 (median 1.56) in cancer therapy patients, which was significantly decreased (P=0.0006) in comparison with controls (range 1.81-2.06, median 1.9). The myocardial 123 I-MIBG washout, calculated from planar images after 15 min and 4 h, and LVEF also showed significant differences, but with some overlap in individual cases. In cancer therapy patients, cardiac abnormalities seen on planar images and additional single-photon emission tomographic images varied from focal defects to diffusely reduced myocardial uptake. It is concluded that 123 I-MIBG heart scintigraphy, which is able to identify cardiac adrenergic neurone abnormalities in the follow-up period after cancer therapy, may help to identify relapsed patients who are at increased risk of developing cardiotoxicity during retreatment with cardiotoxic therapy modalities. (orig.). With 4 figs., 2 tabs

  7. Iodine-123-labeled meta-iodobenzylguanidine myocardial scintigraphy evaluation of Machado-Joseph disease

    International Nuclear Information System (INIS)

    Kazuta, Toshinari; Hayashi, Michiyuki; Yoshita, Mitsuhiro; Hirai, Shunsaku

    1998-01-01

    Iodine-123-labeled meta-iodobenzylguanidine (( 123 I)MIBG), an analogue of guanetidine, is used as a tracer for evaluation of the function of sympathetic neurons. To investigate cardiac sympathetic function in Machado-Joseph disease (MJD), ( 123 I)MIBG myocardial scintigraphy was performed in 12 patients with MJD and 20 controls. In planar imaging studies, the heart to the mediastinum of the average count ratio (H/M) was calculated for both early and delayed images. The mean values of H/M in delayed images of MJD was lower than those of controls (p 123 I)MIBG myocardial scintigraphy in MJD can be seen earlier than abnormal sudomotor system detected by SSR. (author)

  8. Evaluation of myocardial distribution of iodine-123 labeled metaiodobenzylguanidine (123I-MIBG) in normal subjects

    International Nuclear Information System (INIS)

    Tsuchimochi, Shinsaku; Tamaki, Nagara; Shirakawa, Seishi; Fujita, Toru; Yonekura, Yoshiharu; Konishi, Junji; Nohara, Ryuji; Sasayama, Shigetake; Nishioka, Kenya

    1994-01-01

    The normal pattern of the myocardial sympathetic innervation was studied in 15 subjects using gamma camera scintigraphy with iodine-123 labeled metaiodobenzylguanidine ( 123 I-MIBG). Seven younger subjects (mean age 24.6±3.6) and eight older patients (mean age 60.9±8.4) with normal cardiac function were studied. Planar imaging was obtained at 15 minutes and 3 hours, and SPECT was also performed 3 hours after injection of 111 MBq (3 mCi) of MIBG. The younger subjects showed higher the heart to mediastinum count ratio (2.91±0.25 vs. 2.67±0.34; p<0.05) and higher inferior to anterior count ratio (1.19±0.15 vs. 0.97±0.13; p<0.05) on the late scan. The bull's-eye polar map also differences in counts in the mid-inferior (p<0.005), basal-inferior (p<0.005) and mid-lateral sectors (p<0.01). But there was no significant difference in MIBG washout rate from myocardium between two groups. These data suggest that there is a difference of the cardiac sympathetic innervation, with older subjects having fewer sympathetic nerve terminals, especially in inferior than younger subjects. We conclude that the age difference in sympathetic nerve function should be considered in the interpretation of MIBG scan. (author)

  9. Increased cardiac sympathetic activity in patients with hypothyroidism as determined by iodine-123 metaiodobenzylguanidine scintigraphy

    International Nuclear Information System (INIS)

    Momose, Mitsuru; Inaba, Shigeki; Emori, Toshiaki; Imamura, Kimiharu; Kawano, Katsunori; Ueda, Tetsuro; Kobayashi, Hideki; Hosoda, Saichi

    1997-01-01

    Clinical manifestations of hypothyroidism, such as bradycardia, suggest decreased sympathetic tone. However, previous studies in patients with hypothyroidism have suggested that increased plasma noradrenaline (NA) levels represent enhanced general sympathetic activity. As yet, cardiac sympathetic activity (CSA) in hypothyroidism has not been clarified. To evaluate CSA in patients with hypothyroidism, iodine-123 metaiodobenzylguanidine (MIBG) scintigraphy was performed in eight patients with hypothyroidism before therapy and in ten normal control patients. Planar images were obtained at 15 min and 4 h after injection of MIBG. The ratio of early myocardial uptake to the total injected dose (MU) and myocardial clearance of MIBG within 4 h p.i. (MC) were calculated. Plasma NA was also measured, and echocardiography was performed in all patients. Those patients with hypothyroidism in the euthyroid state after medical therapy were also evaluated in a similar manner. Left ventricular ejection fraction, measured by echocardiography, did not differ significantly between the groups. NA, MU and MC were significantly higher in patients with hypothyroidism than in controls, and all parameters were decreased after therapy. MC was well correlated with NA in hypothyroidism (r=0.86) before therapy. We conclude that CSA is increased in patients with hypothyroidism, in parallel with the enhanced general sympathetic activity. (orig.). With 4 figs., 2 tabs

  10. Iodine-123-metaiodobenzylguanidine cardiac scintigraphy in patients with diabetes mellitus. Therapeutic effects of aldose reductase inhibitor and vitamin B{sub 12}

    Energy Technology Data Exchange (ETDEWEB)

    Utsunomiya, Keita [Osaka Medical Coll., Takatsuki (Japan)

    1997-12-01

    Twenty normal volunteers (C group) and 56 patients with non-insulin-dependent diabetes mellitus (NIDDM) who did not have ischemic heart diseases (DM group), were evaluated by means of iodine-123-metaiodobenzylguanidine (MIBG) scintigraphy. The uptake ratio between the cardiac muscle and the upper mediastinum was calculated. The ratio determined from the initial I-123-MIBG scintigraphy image was expressed as HMi, and that determined from the delayed image was expressed as HMd. The washout rate percentage (%WR) was calculated. At least one instance of either the HMi, the HMd, or %WR was outside the mean{+-}1 standard deviation of C group in 34 DM group patients. Aldose reductase inhibitor (ARI) was administered to 17 of the 34 patients and Vitamin B{sub 12} (VB{sub 12}) to the remaining 17 patients, for 3 to 5 months. Before and after treatment, scintigraphic studies with I-123-MIBG were carried out, and the HMi, HMd, and %WR were calculated. There were no significant differences found in FBG, HbA1c, or 1.5-AG levels after treatment with either drug, when compared to the pretreatment values. Both HMi and HMd in the DM group were significantly lower, and %WR was significantly higher than in the C group. The changes in HMi, HMd, and %WR after treatment with ARI were not significant. After treatment with VB{sub 12}, the HMi and HMd levels were significantly increased (p<0.01). Thus, measurement of myocardial MIBG accumulation is a promising new method to detect cardiac sympathetic denervation in diabetic patients. With these changes in treatment, VB{sub 12} was shown to be effective for improvement of HMi and HMd in NIDDM. (author)

  11. Iodine-123-metaiodobenzylguanidine cardiac scintigraphy in patients with diabetes mellitus. Therapeutic effects of aldose reductase inhibitor and vitamin B12

    International Nuclear Information System (INIS)

    Utsunomiya, Keita

    1997-01-01

    Twenty normal volunteers (C group) and 56 patients with non-insulin-dependent diabetes mellitus (NIDDM) who did not have ischemic heart diseases (DM group), were evaluated by means of iodine-123-metaiodobenzylguanidine (MIBG) scintigraphy. The uptake ratio between the cardiac muscle and the upper mediastinum was calculated. The ratio determined from the initial I-123-MIBG scintigraphy image was expressed as HMi, and that determined from the delayed image was expressed as HMd. The washout rate percentage (%WR) was calculated. At least one instance of either the HMi, the HMd, or %WR was outside the mean±1 standard deviation of C group in 34 DM group patients. Aldose reductase inhibitor (ARI) was administered to 17 of the 34 patients and Vitamin B 12 (VB 12 ) to the remaining 17 patients, for 3 to 5 months. Before and after treatment, scintigraphic studies with I-123-MIBG were carried out, and the HMi, HMd, and %WR were calculated. There were no significant differences found in FBG, HbA1c, or 1.5-AG levels after treatment with either drug, when compared to the pretreatment values. Both HMi and HMd in the DM group were significantly lower, and %WR was significantly higher than in the C group. The changes in HMi, HMd, and %WR after treatment with ARI were not significant. After treatment with VB 12 , the HMi and HMd levels were significantly increased (p 12 was shown to be effective for improvement of HMi and HMd in NIDDM. (author)

  12. Impact of exercise rehabilitation on cardiac neuronal function in heart failure. An iodine-123 metaiodobenzylguanidine scintigraphy study

    International Nuclear Information System (INIS)

    Agostini, D.; Bouvard, G.; Lecluse, E.; Grollier, G.; Potier, J.C.; Belin, A.; Babatasi, G.; Amar, M.H.

    1998-01-01

    Exercise training can induce important haemodynamic and metabolic adaptations in patients with chronic heart failure due to severe left ventricular dysfunction. This study examined the impact of exercise rehabilitation on cardiac neuronal function using iodine-123 metaiobodenzylguanidine (MIBG) scintigraphy. Fourteen patients (11 men, 3 women; mean age 48 years; range: 36-66 years) with stable chronic heart failure of NYHA class II-III and an initial resting radionuclide left ventricular ejection fraction (LVEF) 123 I-MIBG scintigraphy provided measurements of cardiac neuronal uptake (heart-mediastinum ratio activity, 4 h after intravenous injection of 185 MBq of MIBG). Radionuclide LVEF was also assessed at the outset and after 6 months of exercise training. Workload (801±428 vs 1229±245 kpm.min -1 , P=0.001), exercise duration (504±190 vs 649±125 s, P=0.02), and myocardial MIBG uptake (135%±19% vs 156%±25%, P=0.02) increased significantly after rehabilitation. However, LVEF did not change significantly (23%±9% vs 21%±10%, p=NS). It is concluded that exercise rehabilitation induces improvement of cardiac neuronal function without having negative effects on cardiac contractility in patients with stable chronic heart failure. (orig.)

  13. Myocardial adrenergic nerve activity in valvular diseases assessed by iodine-123-metaiodobenzylguanidine myocardial scintigraphy

    International Nuclear Information System (INIS)

    Imamura, Yoshihiro; Fukuyama, Takaya

    1997-01-01

    Iodine-123-metaiodobenzylguanidine (MIBG) imaging was used to assess myocardial adrenergic nerve activity in patients with heart failure. MIBG planar images were obtained in 94 patients. The uptake of MIBG, calculated as the heart-to-mediastinum activity ratio in the immediate image (15 min), showed a significant decrease only in patients with severe heart failure due to cardiomyopathy, but was not changed in those with valvular diseases. Storage and release of MIBG, calculated as the percentage myocardial MIBG washout from 15 min to 4 hours after isotope injection, was substantially accelerated in both patients with cardiomyopathy and valvular diseases in proportion to the severity of heart failure. These data suggest that, in severe heart failure associated with cardiomyopathy, norepinephrine uptake is reduced. Also, myocardial adrenergic nerve activity is accelerated in proportion to the severity of heart failure independent of the underlying cause. MIBG images were analyzed in 20 patients with mitral stenosis with the same methods to clarify whether myocardial adrenergic nerve activity is different in patients with heart failure without left ventricular volume or pressure overload. Myocardial uptake of MIBG did not show any significant difference. The percentage myocardial MIBG washout was increased in patients with severe heart failure. The closest correlation was between myocardial washout and cardiac output. In heart failure due to mitral stenosis, myocardial adrenergic nerve activity is intensified. Decrease in cardiac output associated with mitral stenosis acts as a potent stimulus for this intensification. (author)

  14. Impact of exercise rehabilitation on cardiac neuronal function in heart failure. An iodine-123 metaiodobenzylguanidine scintigraphy study

    Energy Technology Data Exchange (ETDEWEB)

    Agostini, D.; Bouvard, G. [Service de Medecine Nucleaire, CHU Cote de Nacre, Caen (France); Lecluse, E.; Grollier, G.; Potier, J.C. [Service de Cardiologie, CHU Cote de Nacre, Caen (France); Belin, A. [Service de Readaptation Cardiaque, CHU Cote de Nacre, Caen (France); Babatasi, G. [Service de Chirurgie Cardio-Thoracique, CHU Cote de Nacre, Caen (France); Amar, M.H. [Centre Francois Baclesse, Caen (France). Service de Recherche Clinique

    1998-03-01

    Exercise training can induce important haemodynamic and metabolic adaptations in patients with chronic heart failure due to severe left ventricular dysfunction. This study examined the impact of exercise rehabilitation on cardiac neuronal function using iodine-123 metaiobodenzylguanidine (MIBG) scintigraphy. Fourteen patients (11 men, 3 women; mean age 48 years; range: 36-66 years) with stable chronic heart failure of NYHA class II-III and an initial resting radionuclide left ventricular ejection fraction (LVEF) <50% were enrolled in the study. Patients underwent progressive, supervised endurance training (treadmill test, Bruce protocol) during a 6-month period (60 sessions, 3 sessions per week) at a cardiac rehabilitation referral centre in order to measure exercise parameters. Planar {sup 123}I-MIBG scintigraphy provided measurements of cardiac neuronal uptake (heart-mediastinum ratio activity, 4 h after intravenous injection of 185 MBq of MIBG). Radionuclide LVEF was also assessed at the outset and after 6 months of exercise training. Workload (801{+-}428 vs 1229{+-}245 kpm.min{sup -1}, P=0.001), exercise duration (504{+-}190 vs 649{+-}125 s, P=0.02), and myocardial MIBG uptake (135%{+-}19% vs 156%{+-}25%, P=0.02) increased significantly after rehabilitation. However, LVEF did not change significantly (23%{+-}9% vs 21%{+-}10%, p=NS). It is concluded that exercise rehabilitation induces improvement of cardiac neuronal function without having negative effects on cardiac contractility in patients with stable chronic heart failure. (orig.)

  15. Uterine uptake of iodine-123 metaiodobenzylguanidine during the menstrual phase of uterine cycle

    International Nuclear Information System (INIS)

    Bomanji, J.; Britton, K.E.

    1987-01-01

    Radioiodinated I-123 metaiodobenzylguanidine (MIBG) has been used for diagnostic purposes for detection of apudomas. In this paper normal physiological uptake of I-123 MIBG by the uterus during the menstrual phase of the uterine cycle is reported. It is likely that I-123 MIBG can be used to evaluate some of the problems in this context

  16. Uterine uptake of iodine-123 metaiodobenzylguanidine during the menstrual phase of uterine cycle

    Energy Technology Data Exchange (ETDEWEB)

    Bomanji, J.; Britton, K.E.

    1987-08-01

    Radioiodinated I-123 metaiodobenzylguanidine (MIBG) has been used for diagnostic purposes for detection of apudomas. In this paper normal physiological uptake of I-123 MIBG by the uterus during the menstrual phase of the uterine cycle is reported. It is likely that I-123 MIBG can be used to evaluate some of the problems in this context.

  17. Influence of drugs on myocardial iodine-123 metaiodobenzylguanidine uptake in rabbit myocardium

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, S.; Karanikas, G.; Rodrigues, M.; Sinzinger, H. [Dept. of Nuclear Medicine, University of Vienna (Austria)

    2000-03-01

    About 15 years ago, iodine-123 metaiodobenzylguanidine (MIBG) myocardial imaging was introduced for the evaluation of myocardial sympathetic nerve function. Two uptake mechanisms for MIBG have so far been identified: uptake type I, a saturable, energy-dependent mechanism, and uptake type II, a non-saturable, energy-independent mechanism. We incubated isolated rabbit myocardial tissue samples with{sup 123}I-MIBG in order to assess the uptake characteristics and the influence of varying incubation conditions. Furthermore, we examined the effects of several drugs and uptake inhibitors on the myocardial uptake of MIBG. The in vitro myocardial uptake of MIBG reached a steady plateau at 23.87%{+-}3.63% after 1 h, i.e. a concentration gradient of 10, in a thermo-independent manner within a concentration range from 1.5 to 1500 {mu}M. This indicates an unsaturable uptake process in the tested concentrations. Pre-incubation with the following drugs caused a significant inhibitory effect on myocardial MIBG uptake: haloperidol, levomepromazine, metoprolol, labetalol and clomipramine. According to our findings, the uptake mechanism seems to be an unspecific process, but the concentration gradient of 10 makes passive diffusion unlikely. Further studies with uptake-II-blocking substances as well as with isolated myocardial cells will be needed to clarify the nature of the myocardial MIBG uptake mechanism. (orig.)

  18. Evaluation of cardiac autonomic nerves by iodine-123 metaiodobenzylguanidine scintigraphy and ambulatory electrocardiography in patients after arterial switch operations

    Energy Technology Data Exchange (ETDEWEB)

    Sakurai, Hajime; Maeda, Masanobu; Miyahara, Ken [Shakaihoken Chukyo Hospital, Nagoya (Japan)] [and others

    2000-05-01

    The autonomic cardiac nerves reach the heart after passing through the vicinity of the aortic root and the pulmonary trunk. The arterial switch operation (ASO) completely transects the ascending aorta and the pulmonary trunk. Therefore, this surgical procedure virtually denerves the heart. Cardiac sympathetic denervation and reinnervation were evaluated in patients after ASO using iodine-123 metaiodobenzylguanidine (MIBG) myocardial scintigraphy and parasympathetic denervation and reinnervation using ambulatory electrocardiography [Holter electrocardiogram (ECG)]. MIBG scintigraphy was performed in 14 patients who underwent ASO (ASO group) and 3 patients who underwent other open heart surgery (control group). All patients in the ASO group underwent the operation in the neonatal or infantile period. Planar and single photon emission computed tomography (SPECT) images of the myocardium were obtained. Defect score was determined by the SPECT images as a semi-quantitative index. The mean interval between ASO and MIBG scintigraphy was 25.6{+-}14.6 months. Holter ECG was also performed in 14 patients in the ASO group and 19 age-matched normal children. The Holter ECGs were plotted on a Lorenz plot. The H index, which is related to vagal tone for the cardiovascular system, was calculated from the R-R intervals. The mean interval between the ASO and Holter ECG was 8.3{+-}9.7 months. MIBG scintigraphy in the control group demonstrated an almost normal homogeneous tracer uptake, but showed extremely reduced tracer uptake and significantly higher defect score in the ASO group. The extent and degree of the reduction of MIBG uptake improved with time after the ASO. The heart-to-mediastinum MIBG count ratio tended to increase with time. The H index of the ASO group was lower than that of normal children (<12 months: Control group 0.0280{+-}0.0068 vs ASO group 0.0219{+-}0.0083), and gradually increased with time (1-3 years: 0.0470{+-}0.0157 vs 0.0314{+-}0.0124). (author)

  19. Evaluation of cardiac autonomic nerves by iodine-123 metaiodobenzylguanidine scintigraphy and ambulatory electrocardiography in patients after arterial switch operations

    International Nuclear Information System (INIS)

    Sakurai, Hajime; Maeda, Masanobu; Miyahara, Ken

    2000-01-01

    The autonomic cardiac nerves reach the heart after passing through the vicinity of the aortic root and the pulmonary trunk. The arterial switch operation (ASO) completely transects the ascending aorta and the pulmonary trunk. Therefore, this surgical procedure virtually denerves the heart. Cardiac sympathetic denervation and reinnervation were evaluated in patients after ASO using iodine-123 metaiodobenzylguanidine (MIBG) myocardial scintigraphy and parasympathetic denervation and reinnervation using ambulatory electrocardiography [Holter electrocardiogram (ECG)]. MIBG scintigraphy was performed in 14 patients who underwent ASO (ASO group) and 3 patients who underwent other open heart surgery (control group). All patients in the ASO group underwent the operation in the neonatal or infantile period. Planar and single photon emission computed tomography (SPECT) images of the myocardium were obtained. Defect score was determined by the SPECT images as a semi-quantitative index. The mean interval between ASO and MIBG scintigraphy was 25.6±14.6 months. Holter ECG was also performed in 14 patients in the ASO group and 19 age-matched normal children. The Holter ECGs were plotted on a Lorenz plot. The H index, which is related to vagal tone for the cardiovascular system, was calculated from the R-R intervals. The mean interval between the ASO and Holter ECG was 8.3±9.7 months. MIBG scintigraphy in the control group demonstrated an almost normal homogeneous tracer uptake, but showed extremely reduced tracer uptake and significantly higher defect score in the ASO group. The extent and degree of the reduction of MIBG uptake improved with time after the ASO. The heart-to-mediastinum MIBG count ratio tended to increase with time. The H index of the ASO group was lower than that of normal children (<12 months: Control group 0.0280±0.0068 vs ASO group 0.0219±0.0083), and gradually increased with time (1-3 years: 0.0470±0.0157 vs 0.0314±0.0124). (author)

  20. Area at risk can be assessed by iodine-123-meta-iodobenzylguanidine single-photon emission computed tomography after myocardial infarction: a prospective study.

    Science.gov (United States)

    Hedon, Christophe; Huet, Fabien; Ben Bouallegue, Fayçal; Vernhet, Hélène; Macia, Jean-Christophe; Cung, Thien-Tri; Leclercq, Florence; Cade, Stéphane; Cransac, Frédéric; Lattuca, Benoit; Vandenberghe, D'Arcy; Bourdon, Aurélie; Benkiran, Meriem; Vauchot, Fabien; Gervasoni, Richard; D'estanque, Emmanuel; Mariano-Goulart, Denis; Roubille, François

    2018-02-01

    Myocardial salvage is an important surrogate endpoint to estimate the impact of treatments in patients with ST-segment elevation myocardial infarction (STEMI). The aim of this study was to evaluate the correlation between cardiac sympathetic denervation area assessed by single-photon emission computed tomography (SPECT) using iodine-123-meta-iodobenzylguanidine (I-MIBG) and myocardial area at risk (AAR) assessed by cardiac magnetic resonance (CMR) (gold standard). A total of 35 postprimary reperfusion STEMI patients were enrolled prospectively to undergo SPECT using I-MIBG (evaluates cardiac sympathetic denervation) and thallium-201 (evaluates myocardial necrosis), and to undergo CMR imaging using T2-weighted spin-echo turbo inversion recovery for AAR and postgadolinium T1-weighted phase sensitive inversion recovery for scar assessment. I-MIBG imaging showed a wider denervated area (51.1±16.0% of left ventricular area) in comparison with the necrosis area on thallium-201 imaging (16.1±14.4% of left ventricular area, Parea (P=0.23) and was adequately correlated (R=0.56, P=0.0002). Myocardial salvage evaluated by SPECT imaging (mismatch denervated but viable myocardium) was significantly higher than by CMR (P=0.02). In patients with STEMI, I-MIBG SPECT, assessing cardiac sympathetic denervation may precisely evaluate the AAR, providing an alternative to CMR for AAR assessment.

  1. Odour identification test and its relation to cardiac 123I‐metaiodobenzylguanidine in patients with drug induced parkinsonism

    Science.gov (United States)

    Lee, Phil Hyu; Yeo, Seung Hyeon; Yong, Seok Woo; Kim, Yun Joong

    2007-01-01

    We investigated olfactory function and its relation to cardiac 123I‐metaiodobenzylguanidine (MIBG) uptake in 15 patients with drug induced parkinsonism (DIP). The mean Cross Cultural Smell Identification (CCSI) score was significantly greater in patients with DIP than in those with Parkinson's disease (PD: 6.9 (1.6) vs 4.4 (2.2); p<0.001); however, the mean CCSI score in patients with DIP was not significantly different from controls. One patient with DIP, whose CCSI score was significantly reduced, also exhibited decreased cardiac MIBG uptake. DIP patients with CCSI scores within the normal range had normal cardiac MIBG uptake. Our study suggests that an olfactory function test may be a useful tool for detecting DIP unrelated to PD and for identifying patients with DIP who have subclinical PD. PMID:17557797

  2. Evaluation of long-term prognosis in patients with heart failure. Is cardiac imaging with iodine-123 metaiodobenzylguanidine useful?

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi

    1998-01-01

    The effect of cardiac sympathetic activity on long-term prognosis in patients with heart failure was evaluated by cardiac imaging with 123 I-MIBG in 46 patients admitted for the first episode of heart failure. Cardiac imaging was performed with 123 I-MIBG and 201 Tl at rest on separate days before discharge. Using whole body imaging, the ratio of cardiac uptake of the isotope to total injected dose was calculated (percentage uptake). The cardiac uptake ratio of 123 I-MIBG (percentage uptake of 123 I-MIBG divided by percentage uptake of 201 Tl) and percentage washout of 123 I-MIBG from the heart over 3 hours were calculated as scintigraphic parameters. Cardiac events were defined as cardiac death or deterioration of heart failure requiring readmission. Scintigraphic parameters, clinical parameters, left ventricular function obtained by echocardiography and neurohumoral parameters were compared between the event group and event-free group. During the follow-up period, cardiac events developed in 14 patients (30%). Univariate analysis showed uptake ratio and washout rate of 123 I-MIBG, percentage uptake of 201 Tl, New York Heart Association class at discharge, fractional shortening of the left ventricle, serum norepinephrine and atrial natriuretic peptide levels differed significantly between the two groups. Cox proportional-hazard analysis showed that the uptake ratio was an independent predictor of cardiac events. When a cut-off point in the uptake ratio equal to or less than 0.50 and age equal to or more than 65 years old were included in the Cox proportional-hazard analysis instead of actual numbers, relative risks of cardiac events by each index were 31.2 and 4.2, respectively. These data suggest that cardiac uptake of 123 I-MIBG is a strong and independent predictor of long-term prognosis in patients with heart failure. (K.H.)

  3. Evaluation of long-term prognosis in patients with heart failure. Is cardiac imaging with iodine-123 metaiodobenzylguanidine useful?

    Energy Technology Data Exchange (ETDEWEB)

    Narita, Michihiro; Kurihara, Tadashi [Sumitomo Hospital, Osaka (Japan)

    1998-06-01

    The effect of cardiac sympathetic activity on long-term prognosis in patients with heart failure was evaluated by cardiac imaging with {sup 123}I-MIBG in 46 patients admitted for the first episode of heart failure. Cardiac imaging was performed with {sup 123}I-MIBG and {sup 201}Tl at rest on separate days before discharge. Using whole body imaging, the ratio of cardiac uptake of the isotope to total injected dose was calculated (percentage uptake). The cardiac uptake ratio of {sup 123}I-MIBG (percentage uptake of {sup 123}I-MIBG divided by percentage uptake of {sup 201}Tl) and percentage washout of {sup 123}I-MIBG from the heart over 3 hours were calculated as scintigraphic parameters. Cardiac events were defined as cardiac death or deterioration of heart failure requiring readmission. Scintigraphic parameters, clinical parameters, left ventricular function obtained by echocardiography and neurohumoral parameters were compared between the event group and event-free group. During the follow-up period, cardiac events developed in 14 patients (30%). Univariate analysis showed uptake ratio and washout rate of {sup 123}I-MIBG, percentage uptake of {sup 201}Tl, New York Heart Association class at discharge, fractional shortening of the left ventricle, serum norepinephrine and atrial natriuretic peptide levels differed significantly between the two groups. Cox proportional-hazard analysis showed that the uptake ratio was an independent predictor of cardiac events. When a cut-off point in the uptake ratio equal to or less than 0.50 and age equal to or more than 65 years old were included in the Cox proportional-hazard analysis instead of actual numbers, relative risks of cardiac events by each index were 31.2 and 4.2, respectively. These data suggest that cardiac uptake of {sup 123}I-MIBG is a strong and independent predictor of long-term prognosis in patients with heart failure. (K.H.)

  4. Scintigraphic assessment of cardiac sympathetic innervation with I-123-metaiodobenzylguanidine in cardiomyopathy. Special reference to cardiac arrhythmia

    Energy Technology Data Exchange (ETDEWEB)

    Asano, Takahisa; Otsuka, Nobuaki; Sone, Teruki; Mimura, Hiroaki; Yanagimoto, Shinichi; Tomomitsu, Tatsushi; Fukunaga, Masao [Kawasaki Medical School, Kurashiki, Okayama (Japan); Morita, Koichi

    1999-07-01

    Cardiac sympathetic imagings with I-123-metaiodobenzylguanidine (MIBG) were carried out in 5 cases with dilated cardiomyopathy (DCM), 26 cases with hypertrophic cardiomyopathy (HCM), and 4 cases without cardiac disease as a control to assess cardiac sympathetic innervation qualitatively and quantitatively, and to clarify the relation of MIBG accumulation to arrhythmia. MIBG scintigraphy was performed at 15 min. (early image) and 4 hr. (delayed image) after intravenous injection of MIBG 111 MBq. The MIBG uptake ratio of mediastinum (H/M) and the cardiac washout rate (WR) from early to delayed images were calculated. On both early and delayed SPECTs, MIBG uptake was assessed by defect scores (DSs). Regarding the cases with HCM, the MIBG uptake ratio, WR, and DS were also compared in cases with and without arrhythmia. In DCM, the MIBG uptake on delayed SPECT was markedly low, the H/M ratio was significantly lower, and the DS was significantly higher than in the control (all p<0.05). As for the WR, there was no significant difference between HCM, DCM and the control. In HCM, significantly reduced MIBG uptake was observed in cases with ventricular techycardia (VT) and in cases with atrial fibrillation (Af), as compared with cases without arrhythmia (all p<0.05). There results suggest that MIBG scintigraphy might be a useful tool in the assessment of cardiac sympathetic abnormalities in cardiomyopathy, especially in cases with arrhythmia. (author)

  5. Assessment of takotsubo (ampulla) cardiomyopathy using iodine-123 metaiodobenzylguanidine scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Pessoa, Pinheiro M.C.; Xavier, Salles S.; Lima, Souza Leao R.; Mansur, J.; Almeida, Altino S. de; Carvalho, Pires A.C.; Gutfilen, B.; Fonseca, Barbosa L.M. da [Hospital Univ. Clementino Fraga Filho, Univ. Federal do Rio de Janeiro (Brazil). Dept. de Radiologia

    2006-12-15

    Purpose: To evaluate the role of cardiac sympathetic innervation in patients whose clinical features consisted of chest pain, transient ST-segment elevation, left ventricular apical akinesis, minimal elevation of cardiac enzymes, and onset of symptoms shortly after a severe stress condition. Material and Methods: Five female patients, mean age 67{+-}14 years, underwent thoracic {sup 123}I-MIBG (planar and SPECT) and 67Ga citrate (planar) scans within 5 days after the onset of symptoms. The {sup 123}I-MIBG myocardial washout rate between early (30 min) and delayed (3 hours) planar images was calculated. All patients presented findings consistent with takotsubo-like syndrome. Echocardiograms showed the characteristic wall motion pattern of significant apical dysfunction. Acute-phase coronary angiographies revealed a non-obstructive pattern. A peculiar apical akinesis and basal normokinesis were observed on the ventriculograms. Results: Impairment of cardiac neuronal uptake of {sup 123}I-MIBG based on a reduction of the heart-to-mediastinum uptake ratio was observed in all patients, while the washout rate was raised in four patients. All patients presented an apical uptake defect in the {sup 123}I-MIBG SPECT and planar images and a normal 67Ga scintigraphy. Conclusion: Our data indicate that ampulla cardiomyopathy (AC) is associated with a cardiac sympathetic innervation deficit characterized by a reduced global {sup 123}I-MIBG uptake and an apical uptake defect. The lack of 67Ga uptake in the acute phase of this syndrome indicates that AC is probably not associated with an inflammatory process.

  6. Iodine-123 metaiodobenzylguanidine scintigraphy and iodine-123 ioflupane single photon emission computed tomography in Lewy body diseases: complementary or alternative techniques?

    Science.gov (United States)

    Treglia, Giorgio; Cason, Ernesto; Cortelli, Pietro; Gabellini, Anna; Liguori, Rocco; Bagnato, Antonio; Giordano, Alessandro; Fagioli, Giorgio

    2014-01-01

    To compare myocardial sympathetic imaging using (123)I-Metaiodobenzylguanidine (MIBG) scintigraphy and striatal dopaminergic imaging using (123)I-Ioflupane (FP-CIT) single photon emission computed tomography (SPECT) in patients with suspected Lewy body diseases (LBD). Ninety-nine patients who performed both methods within 2 months for differential diagnosis between Parkinson's disease (PD) and other parkinsonism (n = 68) or between dementia with Lewy bodies (DLB) and other dementia (n = 31) were enrolled. Sensitivity, specificity, accuracy, positive and negative predictive values of both methods were calculated. For (123) I-MIBG scintigraphy, the overall sensitivity, specificity, accuracy, positive and negative predictive values in LBD were 83%, 79%, 82%, 86%, and 76%, respectively. For (123)I-FP-CIT SPECT, the overall sensitivity, specificity, accuracy, positive and negative predictive values in LBD were 93%, 41%, 73%, 71%, and 80%, respectively. There was a statistically significant difference between these two methods in patients without LBD, but not in patients with LBD. LBD usually present both myocardial sympathetic and striatal dopaminergic impairments. (123)I-FP-CIT SPECT presents high sensitivity in the diagnosis of LBD; (123)I-MIBG scintigraphy may have a complementary role in differential diagnosis between PD and other parkinsonism. These scintigraphic methods showed similar diagnostic accuracy in differential diagnosis between DLB and other dementia. Copyright © 2012 by the American Society of Neuroimaging.

  7. Cardiac 123I-metaiodobenzylguanidine imaging allows early identification of dementia with Lewy bodies during life

    International Nuclear Information System (INIS)

    Estorch, Montserrat; Camacho, Valle; Paredes, Pilar; Rivera, Elisabet; Rodriguez-Revuelto, Ato; Flotats, Albert; Carrio, Ignasi; Kulisevsky, Jaume

    2008-01-01

    Differential diagnosis between dementia with Lewy bodies (DLB) and other neurodegenerative diseases with cognitive impairment represents a clinical challenge. Due to the overlapping of symptoms, the clinical diagnosis can be modified during the prolonged follow-up of these diseases. The purpose of this study was to assess the ability of cardiac metaiodobenzylguanidine (MIBG) imaging for early identification of DLB. Since January 2003, all patients with neurodegenerative diseases with cognitive impairment at their first visit at the Memory Unit and clinical criteria of DLB were consecutively recruited and underwent a cardiac 123 I-MIBG study. The heart-to-mediastinum ratio (HMR) and the washout rate (WR) of cardiac MIBG uptake were obtained. Sixty-five patients were included. After a clinical follow-up of 4 years, the progress of the disease procured a definite diagnosis in 44 (68%) patients: 19 DLB, 12 Alzheimer disease (AD), and 13 other neurodegenerative diseases with cognitive impairment. HMR was significantly decreased in DLB with respect to the other neurodegenerative diseases. WR was only significantly different between DLB and AD. The HMR cut off point of 1.36 differentiated DLB from the other dementias with a sensitivity of 94% and a specificity of 96% with an accuracy of 95%. Cardiac MIBG imaging performed at the time of the first clinical diagnosis of DLB can help early clinical identification or exclusion of this disease. (orig.)

  8. Use of iodine-123 metaiodobenzylguanidine scintigraphy to assess cardiac sympathetic denervation and the impact of hypertension in patients with non-insulin-dependent diabetes mellitus

    International Nuclear Information System (INIS)

    Tamura, Koji; Nakatani, Yuko; Onishi, Satoshi; Utsunomiya, Keita; Saika, Yoshinori; Iwasaka, Toshiji

    1999-01-01

    The objectives of this clinical study using iodine-123 metaiodobenzylguanidine (MIBG) scintigraphy were (a) to evaluate cardiac sympathetic denervation in non-insulin-dependent diabetes mellitus (NIDDM) patients with and without hypertension and (b) to investigate the relation between cardiac sympathetic denervation and prognosis in NIDDM patients. We compared clinical characteristics and MIBG data [heart to mediastinum (H/M) ratio and % washout rate (WR)] in a control group and NIDDM patients with and without hypertension. MIBG scintigraphy was performed in 11 controls and 82 NIDDM patients without overt cardiovascular disease except for hypertension (systolic blood pressure ≥140 and/or diastolic blood pressure ≥90 mmHg). After MIBG examination, blood pressure was measured regularly in all NIDDM patients. There were significant differences between 65 normotensive and 17 hypertensive NIDDM patients with respect to age (55±11 vs 63±12 years, respectively, P<0.05), prevalence of diabetic retinopathy (12% vs 35%, respectively, P<0.05) and systolic blood pressure (120±12 vs 145±16 mmHg, respectively, P<0.001). The H/M ratio in hypertensive NIDDM patients was significantly lower than in the control group (1.81±0.29 vs 2.27±0.20, respectively, P<0.01). During the follow-up period (18± 12 months), 17 NIDDM patients newly developed hypertension after MIBG examination. There were no significant differences in their clinical characteristics compared with persistently normotensive or hypertensive NIDDM patients. %WR in patients with new onset hypertension was significantly higher than in the control group (30.88%±16.87% vs 12.89%±11.94%, respectively, P<0.05). Moreover, in these patients %WR correlated with duration from the date of MIBG scintigraphy to the onset of hypertension (r=-0.512, P<0.05). Five NIDDM patients died during the follow-up period (four newly hypertensive patients and one normotensive patient). There were significant statistical differences

  9. Use of iodine-123 metaiodobenzylguanidine scintigraphy to assess cardiac sympathetic denervation and the impact of hypertension in patients with non-insulin-dependent diabetes mellitus

    Energy Technology Data Exchange (ETDEWEB)

    Tamura, Koji; Nakatani, Yuko; Onishi, Satoshi [Dept. of Internal Medicine, Keihanna Hospital, Hirakata City, Osaka (Japan); Utsunomiya, Keita; Saika, Yoshinori [Dept. of Radiology, Keihanna Hospital, Hirakata City (Japan); Iwasaka, Toshiji [Cardiovascular Center, Kansai Medical University, Osaka (Japan)

    1999-10-01

    The objectives of this clinical study using iodine-123 metaiodobenzylguanidine (MIBG) scintigraphy were (a) to evaluate cardiac sympathetic denervation in non-insulin-dependent diabetes mellitus (NIDDM) patients with and without hypertension and (b) to investigate the relation between cardiac sympathetic denervation and prognosis in NIDDM patients. We compared clinical characteristics and MIBG data [heart to mediastinum (H/M) ratio and % washout rate (WR)] in a control group and NIDDM patients with and without hypertension. MIBG scintigraphy was performed in 11 controls and 82 NIDDM patients without overt cardiovascular disease except for hypertension (systolic blood pressure {>=}140 and/or diastolic blood pressure {>=}90 mmHg). After MIBG examination, blood pressure was measured regularly in all NIDDM patients. There were significant differences between 65 normotensive and 17 hypertensive NIDDM patients with respect to age (55{+-}11 vs 63{+-}12 years, respectively, P<0.05), prevalence of diabetic retinopathy (12% vs 35%, respectively, P<0.05) and systolic blood pressure (120{+-}12 vs 145{+-}16 mmHg, respectively, P<0.001). The H/M ratio in hypertensive NIDDM patients was significantly lower than in the control group (1.81{+-}0.29 vs 2.27{+-}0.20, respectively, P<0.01). During the follow-up period (18{+-} 12 months), 17 NIDDM patients newly developed hypertension after MIBG examination. There were no significant differences in their clinical characteristics compared with persistently normotensive or hypertensive NIDDM patients. %WR in patients with new onset hypertension was significantly higher than in the control group (30.88%{+-}16.87% vs 12.89%{+-}11.94%, respectively, P<0.05). Moreover, in these patients %WR correlated with duration from the date of MIBG scintigraphy to the onset of hypertension (r=-0.512, P<0.05). Five NIDDM patients died during the follow-up period (four newly hypertensive patients and one normotensive patient). There were significant

  10. Dosimetry estimation of SPECT/CT for iodine 123-labeled metaiodobenzylguanidine in children

    Directory of Open Access Journals (Sweden)

    Aida Mhiri

    2015-09-01

    Full Text Available Purpose: To evaluate the additional radiation exposure in terms of effective dose incurred by patients in the CT (computed tomography portion of 123I-MIBG (123II-metaiodobenzylguanidine study with SPECT/CT (Single photon emission computed tomography associated to computed tomography in some pediatric patients of our department. Methods: Data from 123II-MIBG scans comprising 50 children were presented in this study. The contribution of total effective dose imparted by the nuclear tracer and patient's age was calculated. Effective dose from the CT portion of the examination is also estimated.SPECT acquisitions were performed with a dual-headed SPECT unit with an integrated 2-slice CT scanner (Symbia T E-Cam, Siemens Medical Systems, Erlangen, Germany. The CT acquisition were performed using a tube current modulation system (Care Dose 4D. Parameters used were: tube current of 30 - 60 mAs, slice thickness of 3-5 mm, and tube voltage of 110 kV. Results: Our results show that SPECT dosimetry depends on administered activity and patient’s age and weight. For CT scan, effective dose is affected by tube current (mA, tube potential (kVp, rotation speed, pitch, slice thickness, patient mass, and the exact volume of the patient that is being imaged. Conclusion: For children, 123II-MIBG study with SPECT/CT should be performed using the lowest available voltage and current. A sensible choice of these two parameters used can significantly reduce radiation dose, without any compromise in the quality of the diagnostic information.

  11. Merkel cell carcinoma and iodine-131 metaiodobenzylguanidine scan

    International Nuclear Information System (INIS)

    Castagnoli, A.; Biti, G.; De Cristofaro, M.T.R.; Papi, M.G.; Ferri, P.; Magrini, S.M.; Bianchi, S.

    1992-01-01

    Two cases of Merkel cell carcinoma, a neuroendocrine neoplasia of the skin, investigated with iodine, 131 metaiodobenzylguanidine ( 131 I-mIBG) scintigraphy, are reported. Uptake in the tumor was evident only in 1 case. The possible diagnostic and therapeutic role of 131 I-mIBG in patients with this rare neoplasm is discussed. (orig.)

  12. Activity of iodine-123 metaiodobenzylguanidine in childhood neuroblastoma: lack of relation to tumour differentiation in vivo

    International Nuclear Information System (INIS)

    Brans, B.; Wiele, C. van de; Simons, M.; Dierckx, R.A.; Laureys, G.; Dhooge, C.; Schelfhout, V.; Potter, C.R. de

    1998-01-01

    Neuroblastoma (NB) tumour cells have a remarkable tendency to differentiate spontaneously or under the influence of certain drugs. It is not clear whether metaiodobenzylguanidine (MIBG) uptake correlates with differentiation of NB cells. In 28 tumours of 26 patients, iodine-123 MIBG uptake in primary NBs was studied in relation to tumour differentiation, tumour size, cell density and degree of necrosis in subsequently resected specimens. Genetic features such as the presence of chromosomal aberrations (1p-deletion and MYCN amplification) and/or P-glycoprotein (mdr-1 gene product) were also evaluated in relation to MIBG uptake. A highly variable and unpredictable intensity of MIBG uptake was observed in primary as well as secondary resected tumours. This intensity did not relate to any of the above-mentioned factors except that there was a trend towards more intense uptake with increasing size of the tumour. We conclude from our observations that, in contrast to commonly held opinion, well-differentiated tumours do not a priori show a lower MIBG uptake in vivo, even when there are a low number of viable cells and a high degree of necrosis. The degree of differentiation or tumour viability and necrosis following longstanding chemotherapeutic treatment cannot be predicted by the MIBG scan findings. The observed MIBG uptake may be importantly influenced by factors other than those associated with cellular differentiation. (orig.)

  13. Activity of iodine-123 metaiodobenzylguanidine in childhood neuroblastoma: lack of relation to tumour differentiation in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Brans, B.; Wiele, C. van de; Simons, M.; Dierckx, R.A. [Division of Nuclear Medicine, University Hospital Gent, Gent (Belgium); Laureys, G.; Dhooge, C. [Department of Pediatric Hemato-oncology, University Hospital Gent, Gent (Belgium); Schelfhout, V.; Potter, C.R. de [Department of Pathology, University Hospital Gent, Gent (Belgium)

    1998-02-01

    Neuroblastoma (NB) tumour cells have a remarkable tendency to differentiate spontaneously or under the influence of certain drugs. It is not clear whether metaiodobenzylguanidine (MIBG) uptake correlates with differentiation of NB cells. In 28 tumours of 26 patients, iodine-123 MIBG uptake in primary NBs was studied in relation to tumour differentiation, tumour size, cell density and degree of necrosis in subsequently resected specimens. Genetic features such as the presence of chromosomal aberrations (1p-deletion and MYCN amplification) and/or P-glycoprotein (mdr-1 gene product) were also evaluated in relation to MIBG uptake. A highly variable and unpredictable intensity of MIBG uptake was observed in primary as well as secondary resected tumours. This intensity did not relate to any of the above-mentioned factors except that there was a trend towards more intense uptake with increasing size of the tumour. We conclude from our observations that, in contrast to commonly held opinion, well-differentiated tumours do not a priori show a lower MIBG uptake in vivo, even when there are a low number of viable cells and a high degree of necrosis. The degree of differentiation or tumour viability and necrosis following longstanding chemotherapeutic treatment cannot be predicted by the MIBG scan findings. The observed MIBG uptake may be importantly influenced by factors other than those associated with cellular differentiation. (orig.) With 2 figs., 1 tab., 19 refs.

  14. Use of 123I-MIBG scintigraphy to assess the impact of carvedilol on cardiac adrenergic neuronal function in childhood dilated cardiomyopathy

    International Nuclear Information System (INIS)

    Maunoury, Christophe; Acar, Philippe; Sidi, Daniel

    2003-01-01

    Iodine-123 metaiodobenzylguanidine (MIBG) cardiac scintigraphy is a useful tool for the assessment of cardiac adrenergic neuronal function, which is impaired in children with idiopathic dilated cardiomyopathy (DCM). In adults with DCM, long-term treatment with carvedilol improves both cardiac adrenergic neuronal function and left ventricular function. The aim of this prospective study was to evaluate the impact of carvedilol on cardiac adrenergic neuronal function using 123 I-MIBG scintigraphy and on left ventricular function using equilibrium radionuclide angiography in children with DCM. Seventeen patients (11 female, six male; mean age 39±57 months, range 1-168 months) with DCM and left ventricular dysfunction underwent 123 I-MIBG cardiac scintigraphy and equilibrium radionuclide angiography before and after a 6-month period of carvedilol therapy. A static anterior view of the chest was acquired 4 h after intravenous injection of 20-75 MBq of 123 I-MIBG. Cardiac neuronal uptake of 123 I-MIBG was measured using the heart to mediastinum count ratio (HMR). Radionuclide left ventricular ejection fraction (LVEF) was assessed following a standard protocol. MIBG cardiac uptake and left ventricular function respectively increased by 38% and 65% after 6 months of treatment with carvedilol (HMR=223%±49% vs 162%±26%, P<0.0001, and LVEF=43%±17% vs 26%±11%, P<0.0001). Carvedilol can improve cardiac adrenergic neuronal and left ventricular function in children with dilated cardiomyopathy. Further studies are needed to assess the relationship between improvement in MIBG cardiac uptake and the beneficial effects of carvedilol on morbidity and mortality. (orig.)

  15. Evaluation of myocardial sympathetic nerve function in patients with mitral valve prolapse using iodine-123-metaiodobenzylguanidine myocardial scintigraphy

    International Nuclear Information System (INIS)

    Kishi, Fumiko; Nomura, Masahiro; Yukinaka, Michiko

    1996-01-01

    Mitral valve prolapse (MVP) is closely related to myocardial sympathetic nerve function. This study evaluated the presence of impaired myocardial sympathetic nerve function by Iodine-123-metaiodobenzylguanidine (MIBG) scintigraphy in nine patients with MVP. For comparison, 15 healthy subjects without heart disease were investigated (control group). Single photon emission computed tomography (SPECT) and anterior planar myocardial scintigraphy were performed 15 min (initial images) and 3 hours (delayed images) after injection of MIBG (111 MBq). The location and degrees of reduced tracer uptake were evaluated. Myocardial MIBG uptake was quantified by uptake ratio of the heart (H) to upper mediastinum (M) on the anterior planar images (H/M). Percentage washout of MIBG in nine sectors of all oblique slices along the short-axis was calculated. The washout rates were higher at the inferoposterior and septal segments in patients with anterior leaflet prolapse, and at inferoposterior and lateral segments in patients with posterior leaflet prolapse. The bull's eye map showed increased washout rate in the apical and posteroseptal basal segments. There was no significant difference in the H/M ratio between MVP patients and the control group. These results indicate that MIBG can be used to evaluate localized myocardial sympathetic nerve function in MVP. (author)

  16. Use of {sup 123}I-MIBG scintigraphy to assess the impact of carvedilol on cardiac adrenergic neuronal function in childhood dilated cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Maunoury, Christophe [Service de Medecine Nucleaire, Hopital Necker-Enfants Malades, 149 rue de Sevres, 75743, Paris Cedex 15 (France); Acar, Philippe; Sidi, Daniel [Service de Cardiologie Pediatrique, Hopital Necker-Enfants Malades, Paris (France)

    2003-12-01

    Iodine-123 metaiodobenzylguanidine (MIBG) cardiac scintigraphy is a useful tool for the assessment of cardiac adrenergic neuronal function, which is impaired in children with idiopathic dilated cardiomyopathy (DCM). In adults with DCM, long-term treatment with carvedilol improves both cardiac adrenergic neuronal function and left ventricular function. The aim of this prospective study was to evaluate the impact of carvedilol on cardiac adrenergic neuronal function using {sup 123}I-MIBG scintigraphy and on left ventricular function using equilibrium radionuclide angiography in children with DCM. Seventeen patients (11 female, six male; mean age 39{+-}57 months, range 1-168 months) with DCM and left ventricular dysfunction underwent {sup 123}I-MIBG cardiac scintigraphy and equilibrium radionuclide angiography before and after a 6-month period of carvedilol therapy. A static anterior view of the chest was acquired 4 h after intravenous injection of 20-75 MBq of {sup 123}I-MIBG. Cardiac neuronal uptake of {sup 123}I-MIBG was measured using the heart to mediastinum count ratio (HMR). Radionuclide left ventricular ejection fraction (LVEF) was assessed following a standard protocol. MIBG cardiac uptake and left ventricular function respectively increased by 38% and 65% after 6 months of treatment with carvedilol (HMR=223%{+-}49% vs 162%{+-}26%, P<0.0001, and LVEF=43%{+-}17% vs 26%{+-}11%, P<0.0001). Carvedilol can improve cardiac adrenergic neuronal and left ventricular function in children with dilated cardiomyopathy. Further studies are needed to assess the relationship between improvement in MIBG cardiac uptake and the beneficial effects of carvedilol on morbidity and mortality. (orig.)

  17. Relationship between cardiac 123I-Metaiodobenzylguanidine imaging and the transcardiac gradient of neurohumoral factors in patients with dilated cardiomyopathy

    International Nuclear Information System (INIS)

    Matsui, Toshiki; Tsutamoto, Takayoshi; Kinoshita, Masahiko

    2001-01-01

    Cardiac sympathetic nervous function is altered in congestive heart failure (CHF) and the uptake and washout rate of cardiac 123 I-metaiodobenzylguanidine (MIBG) are useful markers for evaluating the severity of it. To assess what parameters predict decreased uptake or increased washout rate of MIBG, the concentrations of neurohumoral factor in both the aorta (Ao) and coronary sinus (CS) were measured, as well as hemodynamic parameters by catheterization, in patients with dilated cardiomyopathy (DCM). MIBG imaging was performed within 1 week of cardiac catheterization. Regarding MIBG parameters, the correlation with the transcardiac gradient of norepinephrine (NE), brain natriuretic peptide (BNP) and hemodynamics was investigated. Stepwise multivariate regression analysis was used to determine which variables closely correlated with cardiac MIBG parameters. There was a significant increase in the NE level between the Ao (446 pg/ml) and the CS (727 pg/ml). According to stepwise multivariate regression analysis, the heart/mediastinum (H/M) ratio independently correlated with the transcardiac gradient of BNP (r=-0.480, p<0.01), and the washout rate independently correlated with the transcardiac gradient of NE (r=0.481, p<0.01). These findings indicate that the H/M ratio may reflect the transcardiac gradient of BNP, which implies the degree of left ventricular dysfunction and/or damage and the washout rate may reflect altered cardiac sympathetic nerve terminal in DCM patients with CHF, suggesting that both the H/M ratio and washout rate provide important information about the failing ventricle. (author)

  18. Evaluation of therapy for dilated cardiomyopathy with heart failure by iodine-123 metaiodobenzyl-guanidine imaging. Comparison with heart rate variability power spectral analysis

    Energy Technology Data Exchange (ETDEWEB)

    Li, Shou-lin; Ikeda, Jun; Takita, Tamotsu; Sekiguchi, Yohei; Demachi, Jun; Chikama, Hisao; Goto, Atsushi; Shirato, Kunio [Tohoku Univ., Sendai (Japan). School of Medicine

    1998-11-01

    The relationship between the myocardial uptake of iodine-123 metaiodobenzylguanidine ({sup 123}I-MIBG) and heart rate variability parameters has not been determined. This study determined the relationship between the change in myocardial uptake of {sup 123}I-MIBG and improvement in left ventricular function after treatment, to determine the usefulness of {sup 123}I-MIBG imaging to assess the effect of therapy on heart failure due to dilated cardiomyopathy (DCM). {sup 123}I-MIBG imaging and power spectral analysis of heart rate variability were performed before and after treatment in 17 patients with heart failure due to DCM. The following parameters were compared before and after treatment: New York Heart Association (NYHA) functional class, radiographic cardiothoracic ratio (CTR), blood pressure, echocardiographic data (left ventricular end-systolic (LVDs) and end-diastolic (LVDd) diameters, left ventricular ejection fraction (LVEF)), plasma concentrations of norepinephrine and epinephrine, heart rate variability power spectral analysis data (mean low frequency (MLF) and high frequency power (MHF)) and the myocardium to mediastinum activity ratio (MYO/M) obtained in early and late images, and washout rate calculated by anterior planar imaging of {sup 123}I-MIBG. The NYHA functional class, LVEF, LVDs, CTR, MLF and MHF improved after treatment. Early MYO/M and late MYO/M improved after treatment. The rate of increase in late MYO/M was positively correlated with the rate of improvement of LVEF after treatment. Furthermore, the late MYO/M was negatively correlated with MLF. Washout rate revealed no correlation with hemodynamic parameters. These findings suggest that late MYO/M is more useful than washout rate to assess the effect of treatment on heart failure due to DCM. Furthermore, the {sup 123}I-MIBG imaging and heart rate variability parameters are useful to assess the autonomic tone in DCM with heart failure. (author)

  19. Evaluation of therapy for dilated cardiomyopathy with heart failure by iodine-123 metaiodobenzyl-guanidine imaging. Comparison with heart rate variability power spectral analysis

    International Nuclear Information System (INIS)

    Li, Shou-lin; Ikeda, Jun; Takita, Tamotsu; Sekiguchi, Yohei; Demachi, Jun; Chikama, Hisao; Goto, Atsushi; Shirato, Kunio

    1998-01-01

    The relationship between the myocardial uptake of iodine-123 metaiodobenzylguanidine ( 123 I-MIBG) and heart rate variability parameters has not been determined. This study determined the relationship between the change in myocardial uptake of 123 I-MIBG and improvement in left ventricular function after treatment, to determine the usefulness of 123 I-MIBG imaging to assess the effect of therapy on heart failure due to dilated cardiomyopathy (DCM). 123 I-MIBG imaging and power spectral analysis of heart rate variability were performed before and after treatment in 17 patients with heart failure due to DCM. The following parameters were compared before and after treatment: New York Heart Association (NYHA) functional class, radiographic cardiothoracic ratio (CTR), blood pressure, echocardiographic data (left ventricular end-systolic (LVDs) and end-diastolic (LVDd) diameters, left ventricular ejection fraction (LVEF)), plasma concentrations of norepinephrine and epinephrine, heart rate variability power spectral analysis data (mean low frequency (MLF) and high frequency power (MHF)) and the myocardium to mediastinum activity ratio (MYO/M) obtained in early and late images, and washout rate calculated by anterior planar imaging of 123 I-MIBG. The NYHA functional class, LVEF, LVDs, CTR, MLF and MHF improved after treatment. Early MYO/M and late MYO/M improved after treatment. The rate of increase in late MYO/M was positively correlated with the rate of improvement of LVEF after treatment. Furthermore, the late MYO/M was negatively correlated with MLF. Washout rate revealed no correlation with hemodynamic parameters. These findings suggest that late MYO/M is more useful than washout rate to assess the effect of treatment on heart failure due to DCM. Furthermore, the 123 I-MIBG imaging and heart rate variability parameters are useful to assess the autonomic tone in DCM with heart failure. (author)

  20. Clinical usefulness of 123I-metaiodobenzylguanidine myocardial scintigraphy in diabetic patients with cardiac sympathetic nerve dysfunction

    International Nuclear Information System (INIS)

    Miyanaga, Hajime; Yoneyama, Satoshi; Kamitani, Tadaaki; Kawasaki, Shingo; Takahashi, Toru; Kunishige, Hiroshi

    1995-01-01

    To assess the clinical utility of 123 I-metaiodobenzylguanidine (MIBG) scintigraphy in evaluating cardiac sympathetic nerve disturbance in diabetic patients, we performed MIBG scintigraphy in 18 diabetic patients and 11 normal controls. Diabetic patients with symptomatic neuropathy (DM2) had a significantly lower heart to mediastinum uptake ratio than did those without neuropathy or normal controls in initial and delayed images (initial image, 1.90±0.27 vs 2.32±0.38, 2.41±0.40, p<0.01; delayed image, 1.80±0.31 vs 2.48±0.35, 2.56±0.28, p<001, respectively). Defect score, assessed visually, were higher in DM2 patients than in patients in the other two groups (initial image, 7±2.6 vs 1.5±1.9, 0.7±0.9; delayed image 10.6±3.3 vs 4.0±2.5, 1.7±1.6 p<0.01, respectively). The maximum washout rate in DM2 patients was also higher than those in patients in the other two groups. The findings of these indices obtained from MIBG scintigraphy coincided with the % low-frequency power extracted from heart rate fluctuations using a power spectral analysis and the results of the Schellong test, which were used to evaluate sympathetic function. These results suggest that MIBG scintigraphy may be useful for evaluating cardiac sympathetic nerve disturbance in patients with diabetes. (author)

  1. Variations in 123I-metaiodobenzylguanidine (MIBG) late heart mediastinal ratios in chronic heart failure: a need for standardisation and validation

    International Nuclear Information System (INIS)

    Verberne, Hein J.; Habraken, Jan B.A.; Eck-Smit, Berthe L.F. van; Agostini, Denis; Jacobson, Arnold F.

    2008-01-01

    There is lack of validation and standardisation of acquisition parameters for myocardial 123 I-metaiodobenzylguanidine (MIBG). This lack of standardisation hampers large scale implementation of 123 I-MIBG parameters in the evaluation of patients with chronic heart failure (CHF). In a retrospective multi-centre study 123 I-MIBG planar scintigrams obtained on 290 CHF patients (82% male; 58% dilated cardiomyopathy; New York Heart Association [NYHA classification] > I) were reanalysed to determine the late heart-to-mediastinum ratio (H/M). There was a large variation in acquisition parameters. Multivariate forward stepwise regression showed that a significant proportion (31%, p 123 I-MIBG uptake. Improved standardisation of cardiac 123 I-MIBG imaging parameters would contribute to increased clinical applicability for this procedure. (orig.)

  2. Reduced cardiac {sup 123}I-metaiodobenzylguanidine uptake in patients with spinocerebellar ataxia type 2: a comparative study with Parkinson's disease

    Energy Technology Data Exchange (ETDEWEB)

    De Rosa, Anna; De Leva, Maria Fulvia; Maddaluno, Gennaro; Filla, Alessandro; De Michele, Giuseppe [University Federico II, Department of Neurosciences and Reproductive and Odontostomatologic Sciences, Naples (Italy); Pappata, Sabina; Pellegrino, Teresa [National Council of Research, Institute of Biostructure and Bioimaging, Naples (Italy); Fiumara, Giovanni [Institute of Diagnostic and Nuclear Development, SDN Foundation, Naples (Italy); Carotenuto, Raffaella; Cuocolo, Alberto [University Federico II, Department of Advanced Biomedical Sciences, Naples (Italy); Petretta, Mario [University Federico II, Department of Translational Medical Sciences, Naples (Italy)

    2013-12-15

    Spinocerebellar ataxia type 2 (SCA2) is an autosomal dominant neurodegenerative disorder characterized by cerebellar ataxia, supranuclear ophthalmoplegia, and peripheral neuropathy. Autonomic nervous system dysfunction is often present. This study evaluated the cardiac sympathetic function in patients with SCA2 using {sup 123}I-metaiodobenzylguanidine (MIBG) in comparison with patients with Parkinson's disease (PD) and control subjects. Nine patients with SCA2, nine patients with PD, and nine control subjects underwent {sup 123}I-MIBG imaging studies from which early and late heart-to-mediastinum (H/M) ratios and myocardial washout rates were calculated. Early (F = 12.3, p < 0.0001) and late (F = 16.8, p < 0.0001) H/M ratios were significantly different among groups. In controls, early and late H/M ratios (2.2 {+-} 0.12 and 2.1 {+-} 0.20) were significantly higher than in patients with SCA2 (1.9 {+-} 0.23 and 1.8 {+-} 0.20, both p < 0.05) and with patients with PD (1.7 {+-} 0.29 and 1.4 {+-} 0.35, both p < 0.001). There was also a significant difference in washout rates among groups (F = 11.7, p < 0.0001). In controls the washout rate (19.9 {+-} 9.6 %) was significantly lower (p < 0.005) than in patients with PD (51.0 {+-} 23.7 %), but not different from that in SCA2 patients (19.5 {+-} 9.4 %). In SCA2 patients, in a multivariable linear regression analysis only the Scale for the Assessment and Rating of Ataxia score was independently associated with early H/M ratio ({beta} = -0.12, p < 0.05). {sup 123}I-MIBG myocardial scintigraphy demonstrated an impairment of cardiac sympathetic function in patients with SCA2, which was less marked than in PD patients. These results suggest that {sup 123}I-MIBG cardiac imaging could become a useful tool for analysing the pathophysiology of SCA2. (orig.)

  3. 123I-MIBG imaging detects cardiac involvement and predicts cardiac events in Churg-Strauss syndrome

    International Nuclear Information System (INIS)

    Horiguchi, Yoriko; Morita, Yukiko; Tsurikisawa, Naomi; Akiyama, Kazuo

    2011-01-01

    In Churg-Strauss syndrome (CSS) it is important to detect cardiac involvement, which predicts poor prognosis. This study evaluated whether 123 I-metaiodobenzylguanidine (MIBG) scintigraphy could detect cardiac damage and predict cardiac events in CSS. 123 I-MIBG scintigraphy was performed in 28 patients with CSS, 12 of whom had cardiac involvement. The early and delayed heart to mediastinum ratio (early H/M and delayed H/M) and washout rate were calculated by using 123 I-MIBG scintigraphy and compared with those in control subjects. Early H/M and delayed H/M were significantly lower and the washout rate was significantly higher in patients with cardiac involvement than in those without and in controls (early H/M, p = 0.0024, p = 0.0001; delayed H/M, p = 0.0002, p = 0.0001; washout rate, p = 0.0012, p = 0.0052 vs those without and vs controls, respectively). Accuracy for detecting cardiac involvement was 86% for delayed H/M and washout rate and 79% for early H/M and B-type natriuretic peptide (BNP). Kaplan-Meier analysis showed significantly lower cardiac event-free rates in patients with early H/M ≤ 2.18 and BNP > 21.8 pg/ml than those with early H/M > 2.18 and BNP ≤ 21.8 pg/ml (log-rank test p = 0.006). Cardiac sympathetic nerve function was damaged in CSS patients with cardiac involvement. 123 I-MIBG scintigraphy was useful in detecting cardiac involvement and in predicting cardiac events. (orig.)

  4. A prediction model for 5-year cardiac mortality in patients with chronic heart failure using {sup 123}I-metaiodobenzylguanidine imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Kenichi; Matsuo, Shinro [Kanazawa University Hospital, Department of Nuclear Medicine, Kanazawa (Japan); Nakata, Tomoaki [Sapporo Medical University School of Medicine, Second Department of Internal Medicine (Cardiology), Sapporo (Japan); Hakodate-Goryoukaku Hospital, Department of Cardiology, Hakodate (Japan); Yamada, Takahisa [Osaka Prefectural General Medical Center, Department of Cardiology, Osaka (Japan); Yamashina, Shohei [Toho University Omori Medical Center, Department of Cardiovascular Medicine, Tokyo (Japan); Momose, Mitsuru [Tokyo Women' s Medical University, Department of Nuclear Medicine, Tokyo (Japan); Kasama, Shu [Cardiovascular Hospital of Central Japan, Department of Cardiology, Shibukawa (Japan); Matsui, Toshiki [Social Insurance Shiga General Hospital, Department of Cardiology, Otsu (Japan); Travin, Mark I. [Albert Einstein Medical College, Department of Cardiology and Nuclear Medicine, Montefiore Medical Center, Bronx, NY (United States); Jacobson, Arnold F. [GE Healthcare, Medical Diagnostics, Princeton, NJ (United States)

    2014-09-15

    Prediction of mortality risk is important in the management of chronic heart failure (CHF). The aim of this study was to create a prediction model for 5-year cardiac death including assessment of cardiac sympathetic innervation using data from a multicenter cohort study in Japan. The original pooled database consisted of cohort studies from six sites in Japan. A total of 933 CHF patients who underwent {sup 123}I-metaiodobenzylguanidine (MIBG) imaging and whose 5-year outcomes were known were selected from this database. The late MIBG heart-to-mediastinum ratio (HMR) was used for quantification of cardiac uptake. Cox proportional hazard and logistic regression analyses were used to select appropriate variables for predicting 5-year cardiac mortality. The formula for predicting 5-year mortality was created using a logistic regression model. During the 5-year follow-up, 205 patients (22 %) died of a cardiac event including heart failure death, sudden cardiac death and fatal acute myocardial infarction (64 %, 30 % and 6 %, respectively). Multivariate logistic analysis selected four parameters, including New York Heart Association (NYHA) functional class, age, gender and left ventricular ejection fraction, without HMR (model 1) and five parameters with the addition of HMR (model 2). The net reclassification improvement analysis for all subjects was 13.8 % (p < 0.0001) by including HMR and its inclusion was most effective in the downward reclassification of low-risk patients. Nomograms for predicting 5-year cardiac mortality were created from the five-parameter regression model. Cardiac MIBG imaging had a significant additive value for predicting cardiac mortality. The prediction formula and nomograms can be used for risk stratifying in patients with CHF. (orig.)

  5. Regional sympathetic denervation after myocardial infarction in humans detected noninvasively using I-123-metaiodobenzylguanidine

    Energy Technology Data Exchange (ETDEWEB)

    Stanton, M.S.; Tuli, M.M.; Radtke, N.L.; Heger, J.J.; Miles, W.M.; Mock, B.H.; Burt, R.W.; Wellman, H.N.; Zipes, D.P. (Indiana Univ. School of Medicine, IN (USA))

    1989-11-15

    Transmural myocardial infarction in dogs produces denervation of sympathetic nerves in viable myocardium apical to the infarct that may be arrhythmogenic. It is unknown whether sympathetic denervation occurs in humans. The purpose of this study was to use iodine-123-metaiodobenzylguanidine (MIBG), a radiolabeled guanethidine analog that is actively taken up by sympathetic nerve terminals, to image noninvasively the cardiac sympathetic nerves in patients with and without ventricular arrhythmias after myocardial infarction. Results showed that 10 of 12 patients with spontaneous ventricular tachyarrhythmias after myocardial infarction exhibited regions of thallium-201 uptake indicating viable perfused myocardium, with no MIBG uptake. Such a finding is consistent with sympathetic denervation. One patient had frequent episodes of nonsustained ventricular tachycardia induced at exercise testing that was eliminated by beta-adrenoceptor blockade. Eleven of the 12 patients had ventricular tachycardia induced at electrophysiologic study and metoprolol never prevented induction. Sympathetic denervation was also detected in two of seven postinfarction patients without ventricular arrhythmias. Normal control subjects had no regions lacking MIBG uptake. This study provides evidence that regional sympathetic denervation occurs in humans after myocardial infarction and can be detected noninvasively by comparing MIBG and thallium-201 images. Although the presence of sympathetic denervation may be related to the onset of spontaneous ventricular tachyarrhythmias in some patients, it does not appear to be related to sustained ventricular tachycardia induced at electrophysiologic study.

  6. Iodine-131 metaiodobenzylguanidine intra- and extravesicular accumulation in the rat heart

    International Nuclear Information System (INIS)

    Nakajo, M.; Shimabukuro, K.; Yoshimura, H.; Yonekura, R.; Nakabeppu, Y.; Tanoue, P.; Shinohara, S.

    1986-01-01

    In order to establish the appropriate time for [ 123 I]MIBG human myocardial imaging to assess the adrenergic nerve activity, the time courses of metaiodobenzylguanidine (MIBG) intra- and extravesicular accumulation in the rat heart were estimated by using [ 131 I]MIBG and reserpine. In the heart, the intravesicular accumulation was relatively constant, while the extravesicular accumulation decreased rapidly from 5 min to 6 hr. The intravesicular percentage of the total cardiac tissue concentration reached a plateau value of 50% at 4 hr after i.v. injection of [ 131 I]MIBG. In the spleen, similar time courses were observed as those in the heart, both of these organs being richly innervated by adrenergic nerves. Along with the time activity difference previously observed in the human hearts, these results suggest that at 4 hr post i.v. injection, [ 123 I]MIBG myocardial imaging will best express the neuronal accumulation of the tracer and may be useful for the assessment of adrenergic function in various pathological conditions of the human heart

  7. Impact of aging on cardiac sympathetic innervation measured by {sup 123}I-mIBG imaging in patients with systolic heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Rengo, Giuseppe; Ferrara, Nicola [Scientific Institute of Telese Terme, Salvatore Maugeri Foundation, IRCCS, Telese Terme (Italy); University of Naples Federico II, Division of Geriatrics, Department of Translational Medical Sciences, Naples (Italy); Pagano, Gennaro; Formisano, Roberto; Komici, Klara; Petraglia, Laura; Parisi, Valentina; Femminella, Grazia Daniela; De Lucia, Claudio; Cannavo, Alessandro; Memmi, Alessia; Leosco, Dario [University of Naples Federico II, Division of Geriatrics, Department of Translational Medical Sciences, Naples (Italy); Vitale, Dino Franco [Scientific Institute of Telese Terme, Salvatore Maugeri Foundation, IRCCS, Telese Terme (Italy); Paolillo, Stefania [Institute of Diagnostic and Nuclear Development, SDN Foundation, Naples (Italy); Attena, Emilio [Fatebenefratelli Hospital, Department of Cardiology, Naples (Italy); Pellegrino, Teresa [Institute of Biostructures and Bioimages of the National Council of Research, Naples (Italy); Federico II University of Naples, Division of Imaging, Radiotherapy, Neuroradiology, and Medical Physics, Department of Advanced Biomedical Sciences, Naples (Italy); Dellegrottaglie, Santo [Ospedale Medico-Chirurgico Accreditato Villa dei Fiori, Division of Cardiology, Acerra, Naples (Italy); Trimarco, Bruno; Filardi, Pasquale Perrone [Federico II University of Naples, Division of Cardiology, Department of Advanced Biomedical Sciences, Naples (Italy); Cuocolo, Alberto [Institute of Diagnostic and Nuclear Development, SDN Foundation, Naples (Italy); Federico II University of Naples, Division of Imaging, Radiotherapy, Neuroradiology, and Medical Physics, Department of Advanced Biomedical Sciences, Naples (Italy)

    2016-12-15

    Sympathetic nervous system (SNS) hyperactivity is a salient characteristic of chronic heart failure (HF) and contributes to the progression of the disease. Iodine-123 meta-iodobenzylguanidine ({sup 123}I-mIBG) imaging has been successfully used to assess cardiac SNS activity in HF patients and to predict prognosis. Importantly, SNS hyperactivity characterizes also physiological ageing, and there is conflicting evidence on cardiac {sup 123}I-mIBG uptake in healthy elderly subjects compared to adults. However, little data are available on the impact of ageing on cardiac sympathetic nerve activity assessed by {sup 123}I-mIBG scintigraphy, in patients with HF. We studied 180 HF patients (age = 66.1 ± 10.5 years [yrs]), left ventricular ejection fraction (LVEF = 30.6 ± 6.3 %) undergoing cardiac {sup 123}I-mIBG imaging. Early and late heart to mediastinum (H/M) ratios and washout rate were calculated in all patients. Demographic, clinical, and echocardiographic data were also collected. Our study population consisted of 53 patients aged >75 years (age = 77.7 ± 4.0 year), 67 patients aged 62-72 years (age = 67.9 ± 3.2 years) and 60 patients aged ≤61 year (age = 53.9 ± 5.6 years). In elderly patients, both early and late H/M ratios were significantly lower compared to younger patients (p < 0.05). By multivariate analysis, H/M ratios (both early and late) and washout rate were significantly correlated with LVEF and age. Our data indicate that, in a population of HF patients, there is an independent age-related effect on cardiac SNS innervation assessed by {sup 123}I-mIBG imaging. This finding suggests that cardiac {sup 123}I-mIBG uptake in patients with HF might be affected by patient age. (orig.)

  8. A comparison of iodine-123 meta-iodobenzylguanidine scintigraphy and single bone marrow aspiration biopsy in the diagnosis and follow-up of 26 children with neuroblastoma

    International Nuclear Information System (INIS)

    Osmanagaoglu, K.; Lippens, M.; Benoit, Y.; Obrie, E.; Schelstraete, K.; Simons, M.

    1993-01-01

    In staging neuroblastomas, the demonstration of tumoural invasion of the bone marrow is an important criterion with regard to the therapeutic prospects and the prognosis. Iliac crest aspiration sampling has been used routinely for the detection of bone marrow metastases in neuroblastoma, but due to the limited character of the sampling it sometimes leads to false-negative results. Another procedure used to determine the extent of neuroblastoma is metaiodobenzylguanidine (mIBG) scintigraphy. To establish the respective merits of both diagnostic techniques, 148 iodine-123 mIBG scans of 26 children with neuroblastoma were re-evaluated and compared with the results of routine bone marrow samples obtained within a 4-week period before or after scanning. The results indicate that for the assessment of bone marrow infiltration by neuroblastoma, 123 I-mIBG scintigraphy is more sensitive than the conventional cytological examination of bone marrow smears routinely obtained from the iliac crest, has a very high sensitivity in excluding bone marrow invasion, has a high specificity for detecting bone marrow invasion, appears to be able to detect early tumoural deposits in the bone marrow before osseous invasion occurs as shown on the MDP scans and is superior to 99m Tc-MDP bone scan in detecting bone/bone marrow metastases of neuroblastoma

  9. {sup 123}I-MIBG imaging detects cardiac involvement and predicts cardiac events in Churg-Strauss syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Horiguchi, Yoriko; Morita, Yukiko [National Hospital Organization Sagamihara National Hospital, Department of Cardiology, Sagamihara City, Kanagawa (Japan); Tsurikisawa, Naomi; Akiyama, Kazuo [National Hospital Organization Sagamihara National Hospital, Clinical Research Centre for Allergy and Rheumatology, Sagamihara City, Kanagawa (Japan)

    2011-02-15

    In Churg-Strauss syndrome (CSS) it is important to detect cardiac involvement, which predicts poor prognosis. This study evaluated whether {sup 123}I-metaiodobenzylguanidine (MIBG) scintigraphy could detect cardiac damage and predict cardiac events in CSS. {sup 123}I-MIBG scintigraphy was performed in 28 patients with CSS, 12 of whom had cardiac involvement. The early and delayed heart to mediastinum ratio (early H/M and delayed H/M) and washout rate were calculated by using {sup 123}I-MIBG scintigraphy and compared with those in control subjects. Early H/M and delayed H/M were significantly lower and the washout rate was significantly higher in patients with cardiac involvement than in those without and in controls (early H/M, p = 0.0024, p = 0.0001; delayed H/M, p = 0.0002, p = 0.0001; washout rate, p = 0.0012, p = 0.0052 vs those without and vs controls, respectively). Accuracy for detecting cardiac involvement was 86% for delayed H/M and washout rate and 79% for early H/M and B-type natriuretic peptide (BNP). Kaplan-Meier analysis showed significantly lower cardiac event-free rates in patients with early H/M {<=} 2.18 and BNP > 21.8 pg/ml than those with early H/M > 2.18 and BNP {<=} 21.8 pg/ml (log-rank test p = 0.006). Cardiac sympathetic nerve function was damaged in CSS patients with cardiac involvement. {sup 123}I-MIBG scintigraphy was useful in detecting cardiac involvement and in predicting cardiac events. (orig.)

  10. Clinical relationship of myocardial sympathetic nervous activity to cardiovascular functions in chronic heart failure. Assessment by myocardial scintigraphy with 123I-metaiodobenzylguanidine

    International Nuclear Information System (INIS)

    Wada, Yukoh; Miura, Masaetsu; Fujiwara, Satomi; Mori, Shunpei; Seiji, Kazumasa; Kimura, Tokihisa

    2003-01-01

    The aim of this study was to clarify the relationship between cardiac sympathetic nervous activity (SNA) assessed by radioiodinated metaiodobenzylguanidine ( 123 I-MIBG), an analogue of norepinephrine and cardiovascular functions in patients with chronic heart failure (CHF). Subjects were 17 patients with CHF. A dose of 111 MBq of 123 I-MIBG was administered intravenously, and 5-minute anterior planar images were obtained 15 minutes (early image) and 3 hours (delayed image) after the injection. The heart/mediastinum (H/M) count ratio was defined to quantify cardiac 123 I-MIBG uptake. The washout ratio (WR) of 123 I-MIBG from the heart was calculated as follows: (early counts-delayed counts)/early counts x 100 (%). Echocardiography was performed on all patients within 1 week of 123 I-MIBG scintigraphy to measure stroke volume index (SVI). Blood pressure and heart rate (HR) in the resting state were also recorded to calculate cardiovascular functions including cardiac output, pulse pressure (PP), and mean blood pressure. Significant linear correlations were found between the early H/M ratio of 123 I-MIBG and SVI, and between the delayed H/M ratio of 123 I-MIBG and SVI, respectively. WR of 123 I-MIBG was correlated with HR, and was inversely correlated with SVI and with PP, respectively. It is likely that a decrease in SVI is associated with enhanced cardiac SNA in severe CHF. 123 I-MIBG scintigraphy is effective in assessing the cardiac functional status and SNA in patients with CHF in vivo. Moreover, changes in PP and HR indicate well alteration in SNA. (author)

  11. The relationship between the improvement of cardiac function and the myocardial uptake of I-123 metaiodobenzylguanidine in patients with dilated cardiomyopathy treated by beta-blocker

    International Nuclear Information System (INIS)

    Wakita, Tomio; Numata, Yuichi; Ogata, Yasuhiro; Harada, Eisaku; Mizumasa, Yutaka

    1995-01-01

    Chronic β-blocker therapy improves hemodynamics and cardiac function in patients with idiopathic dilated cardiomyopathy. However, the change in myocardial uptake of I-123 metaiodobenzylguanidine ( 123 I-MIBG) before and after treatment has not been determined. Myocardial imaging with 123 I-MIBG was performed before and 2 or 3 months after β-blocker (bisoprolol) therapy in 11 patients with dilated cardiomyopathy. The following parameters were compared before and after the treatment : 1) New York Heart Association functional class, 2) X-ray cardiothoracic ratio, 3) heart rate and blood pressure, 4) echocardiographic data (left ventricular end-diastolic and end-systolic diameters, and left ventricular ejection fraction), 5) plasma concentrations of epinephrine, norepinephrine and human atrial natriuretic peptide (HANP), and 6) exercise tolerance time by treadmill. The heart-to-mediastinum ratio of 123 I-MIBG activities obtained 3 hours after intravenous injection (late H/M) and washout rate improved significantly after β-blocker therapy. Cardiothoracic ratio, heart rate, echocardiographic parameters, HANP and exercise tolerance also improved significantly. Late H/M had no significant relationship with any of the clinical parameters, but washout rate was significantly related to left ventricular ejection fraction. These findings suggest that washout rate may be useful to assess the effect of short-term β-blocker therapy in dilated cardiomyopathy patients. (author)

  12. Variations in {sup 123}I-metaiodobenzylguanidine (MIBG) late heart mediastinal ratios in chronic heart failure: a need for standardisation and validation

    Energy Technology Data Exchange (ETDEWEB)

    Verberne, Hein J. [University of Amsterdam, Department of Nuclear Medicine, Academic Medical Center, Amsterdam (Netherlands); Academic Medical Center, F2-238, Department of Nuclear Medicine, P.O.Box 22700, Amsterdam (Netherlands); Habraken, Jan B.A.; Eck-Smit, Berthe L.F. van [University of Amsterdam, Department of Nuclear Medicine, Academic Medical Center, Amsterdam (Netherlands); Agostini, Denis [CHU Cote de Nacre, Department of Nuclear Medicine, Caen (France); Jacobson, Arnold F. [GE Healthcare, Princeton, NJ (United States)

    2008-03-15

    There is lack of validation and standardisation of acquisition parameters for myocardial {sup 123}I-metaiodobenzylguanidine (MIBG). This lack of standardisation hampers large scale implementation of {sup 123}I-MIBG parameters in the evaluation of patients with chronic heart failure (CHF). In a retrospective multi-centre study {sup 123}I-MIBG planar scintigrams obtained on 290 CHF patients (82% male; 58% dilated cardiomyopathy; New York Heart Association [NYHA classification] > I) were reanalysed to determine the late heart-to-mediastinum ratio (H/M). There was a large variation in acquisition parameters. Multivariate forward stepwise regression showed that a significant proportion (31%, p < 0.001) of the variation in late H/M could be explained by a model containing patient-related variables and acquisition parameters. Left ventricular ejection fraction (p < 0.001), type of collimation (p < 0.001), acquisition duration (p = 0.001), NYHA class (p = 0.028) and age (p = 0.034) were independent predictors of late H/M. Acquisitions parameters are independent contributors to the variation of semi-quantitative measurements of cardiac {sup 123}I-MIBG uptake. Improved standardisation of cardiac {sup 123}I-MIBG imaging parameters would contribute to increased clinical applicability for this procedure. (orig.)

  13. The development of iodine-123-methyl-branched fatty acids and their applications in nuclear cardiology

    International Nuclear Information System (INIS)

    Knapp, F.F. Jr.; Kropp, J.; Goodman, M.M.

    1993-01-01

    Continuous interest in the use of iodine-123-labeled fatty acids for myocardial imaging results from observations from a variety of studies that in many types of cardiac disease, regional fatty acid myocardial uptake patterns are often different than regional distribution of flow tracers. These differences may reflect alterations in important parameters of metabolism which can be useful for patient management or therapeutic strategy decision making. In addition, use of iodine-123-labeled fatty acid distribution may represent a unique metabolic probe to relate some aspects of the metabolism of these substrates with the regional viability of cardiac tissue. The use of such viability makers could provide important prognostic information on myocardial salvage, helping to identify patients for revascularization or angioplasty. Clinical studies are currently in progress with the iodine-123-labeled 15-(p-iodophenyl)-3-R,S-methylpentadecanoic acid (BMIPP) fatty acid analogue at several institutions. The goals of this paper are to discuss development of the concept of metabolic trapping of fatty acids, to briefly review development and evaluation of various radioiodinated methyl-branched fatty acids and to discuss recent patient studies with iodine-123 (BMIPP) using single photon emission computerized tomography (SPECT). (author)

  14. Industrial system for producing iodine-123

    International Nuclear Information System (INIS)

    Brantley, J.C.

    1985-01-01

    An industrial system to produce iodine-123 required a complex set of steps involving new approaches by the Food and Drug Administration, difficult distribution procedures, and evidence from potential users that either very pure iodine-123 or inexpensive iodine-123 is needed. Industry has shown its willingness to invest in new radionuclides but needs strong evidence as to product potential to justify those investments

  15. Clinical application of l-123 MlBG cardiac imaging

    International Nuclear Information System (INIS)

    Kang, Do Young

    2004-01-01

    Cardiac neurotransmission imaging allows in vivo assessment of presynaptic reuptake, neurotransmitter storage and postsynaptic receptors. Among the various neurotransmitter, I-123 MlBG is most available and relatively well-established. Metaiodobenzylguanidine (MIBG) is an analogue of the false neurotransmitter guanethidine. It is taken up to adrenergic neurons by uptake-1 mechanism as same as norepinephrine. As tagged with I-123, it can be used to image sympathetic function in various organs including heart with planar or SPECT techniques. I-123 MIBG imaging has a unique advantage to evaluate myocardial neuronal activity in which the heart has no significant structural abnormality or even no functional derangement measured with other conventional examination. In patients with cardiomyopathy and heart failure, this imaging has most sensitive technique to predict prognosis and treatment response of betablocker or ACE inhibitor. In diabetic patients, it allow very early detection of autonomic neuropathy. In patients with dangerous arrhythmia such as ventricular tachycardia or fibrillation, MIBG imaging may be only an abnormal result among various exams. In patients with ischemic heart disease, sympathetic derangement may be used as the method of risk stratification. In heart transplanted patients, sympathetic reinnervation is well evaluated. Adriamycin-induced cardiotoxicity is detected earlier than ventricular dysfunction with sympathetic dysfunction. Neurodegenerative disorder such as Parkinson's disease or dementia with Lewy bodies has also cardiac sympathetic dysfunction. Noninvasive assessment of cardiac sympathetic nerve activity with l-123 MlBG imaging may be improve understanding of the pathophysiology of cardiac disease and make a contribution to predict survival and therapy efficacy

  16. Clinical application of l-123 MlBG cardiac imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Do Young [College of Medicine, Donga Univ., Busan (Korea, Republic of)

    2004-10-01

    Cardiac neurotransmission imaging allows in vivo assessment of presynaptic reuptake, neurotransmitter storage and postsynaptic receptors. Among the various neurotransmitter, I-123 MlBG is most available and relatively well-established. Metaiodobenzylguanidine (MIBG) is an analogue of the false neurotransmitter guanethidine. It is taken up to adrenergic neurons by uptake-1 mechanism as same as norepinephrine. As tagged with I-123, it can be used to image sympathetic function in various organs including heart with planar or SPECT techniques. I-123 MIBG imaging has a unique advantage to evaluate myocardial neuronal activity in which the heart has no significant structural abnormality or even no functional derangement measured with other conventional examination. In patients with cardiomyopathy and heart failure, this imaging has most sensitive technique to predict prognosis and treatment response of betablocker or ACE inhibitor. In diabetic patients, it allow very early detection of autonomic neuropathy. In patients with dangerous arrhythmia such as ventricular tachycardia or fibrillation, MIBG imaging may be only an abnormal result among various exams. In patients with ischemic heart disease, sympathetic derangement may be used as the method of risk stratification. In heart transplanted patients, sympathetic reinnervation is well evaluated. Adriamycin-induced cardiotoxicity is detected earlier than ventricular dysfunction with sympathetic dysfunction. Neurodegenerative disorder such as Parkinson's disease or dementia with Lewy bodies has also cardiac sympathetic dysfunction. Noninvasive assessment of cardiac sympathetic nerve activity with l-123 MlBG imaging may be improve understanding of the pathophysiology of cardiac disease and make a contribution to predict survival and therapy efficacy.

  17. Homocysteine levels are associated with the results of 123I-metaiodobenzylguanidine myocardial scintigraphy in type 2 diabetic patients

    International Nuclear Information System (INIS)

    Anan, Futoshi; Yonemochi, Hidetoshi; Nakagawa, Mikiko; Saikawa, Tetsunori; Masaki, Takayuki; Takahashi, Naohiko; Yoshimatsu, Hironobu; Eshima, Nobuoki

    2007-01-01

    Elevated total plasma homocysteine (tHcy) levels and cardiovascular autonomic dysfunction are associated with a high mortality in type 2 diabetic patients. We tested the hypothesis that hyperhomocysteinemia is associated with insulin resistance and cardiovascular autonomic dysfunction in type 2 diabetic patients not receiving insulin treatment. The study group consisted of 17 type 2 diabetic patients with high tHcy levels (>15 mmol/l, age 58±5 years, high tHcy group). The control group consisted of 23 age-matched type 2 diabetic patients with normal tHcy levels (≤15 mmol/l, age 58±9 years, normal tHcy group). Cardiovascular autonomic function was assessed by baroreflex sensitivity, heart rate variability, plasma norepinephrine concentrations, and cardiac 123 I-metaiodobenzylguanidine (MIBG) scintigraphy. Early and delayed 123 I-MIBG myocardial uptake values were lower (p 123 I-MIBG was higher (p 123 I-MIBG at the delayed phase. Our results demonstrate that high levels of tHcy are associated with depressed cardiovascular autonomic function and insulin resistance in patients with type 2 diabetes mellitus. (orig.)

  18. Abdominal visceral fat accumulation is associated with the results of 123I-metaiodobenzylguanidine myocardial scintigraphy in type 2 diabetic patients

    International Nuclear Information System (INIS)

    Anan, Futoshi; Masaki, Takayuki; Takahashi, Naohiko; Yoshimatsu, Hironobu; Yonemochi, Hidetoshi; Nakagawa, Mikiko; Saikawa, Tetsunori; Eshima, Nobuoki

    2007-01-01

    We tested the hypothesis that increased abdominal visceral accumulation (VFA) is associated with insulin resistance and cardiovascular autonomic dysfunction in type 2 diabetic patients not receiving insulin treatment. The fat distribution was evaluated by measuring the VFA by abdominal computed tomography at the umbilical level. The study group consisted of 24 type 2 diabetic patients with high VFA (≥100 cm 2 , age 60 ± 8 years, high VFA group). The control group consisted of 19 age-matched type 2 diabetic patients with normal VFA ( 2 , age 60 ± 7 years, normal VFA group). Cardiovascular autonomic function was assessed by baroreflex sensitivity, heart rate variability, plasma norepinephrine concentrations, and cardiac 123 I-metaiodobenzylguanidine (MIBG) scintigraphy. Early and delayed 123 I-MIBG myocardial uptake values were lower (p 123 I-MIBG was higher (p 123 I-MIBG during the delayed phase. Our results demonstrate that the level of VFA is associated with depressed cardiovascular autonomic function and insulin resistance in patients with type 2 diabetes mellitus. (orig.)

  19. Cardiac sympathetic innervation assessed with (123)I-MIBG retains prognostic utility in diabetic patients with severe left ventricular dysfunction evaluated for primary prevention implantable cardioverter-defibrillator.

    Science.gov (United States)

    García-González, P; Fabregat-Andrés, Ó; Cozar-Santiago, P; Sánchez-Jurado, R; Estornell-Erill, J; Valle-Muñoz, A; Quesada-Dorador, A; Payá-Serrano, R; Ferrer-Rebolleda, J; Ridocci-Soriano, F

    2016-01-01

    Scintigraphy with iodine-123-metaiodobenzylguanidine ((123)I-MIBG) is a non-invasive tool for the assessment of cardiac sympathetic innervation (CSI) that has proven to be an independent predictor of survival. Recent studies have shown that diabetic patients with heart failure (HF) have a higher deterioration in CSI. It is unknown if (123)I-MIBG has the same predictive value for diabetic and non-diabetic patients with advanced HF. An analysis is performed to determine whether CSI with (123)I-MIBG retains prognostic utility in diabetic patients with HF, evaluated for a primary prevention implantable cardioverter-defibrillator (ICD). Seventy-eight consecutive HF patients (48 diabetic) evaluated for primary prevention ICD implantation were prospectively enrolled and underwent (123)I-MIBG to assess CSI (heart-to-mediastinum ratio - HMR). A Cox proportional hazards multivariate analysis was used to determine the influence of (123)I-MIBG images for prediction of cardiac events in both diabetic and non-diabetic patients. The primary end-point was a composite of arrhythmic event, cardiac death, or admission due to HF. During a mean follow-up of 19.5 [9.3-29.3] months, the primary end-point occurred in 24 (31%) patients. Late HMR was significantly lower in diabetic patients (1.30 vs. 1.41, p=0.014). Late HMR≤1.30 was an independent predictor of cardiac events in diabetic (hazard ratio 4.53; p=0.012) and non-diabetic patients (hazard ratio 12.31; p=0.023). Diabetic patients with HF evaluated for primary prevention ICD show a higher deterioration in CSI than non-diabetics; nevertheless (123)I-MIBG imaging retained prognostic utility for both diabetic and non-diabetic patients. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  20. Prognostic value of 123I-metaiodobenzylguanidine in patients with various heart diseases

    International Nuclear Information System (INIS)

    Nagamatsu, Hitoshi; Momose, Mitsuru; Kobayashi, Hideki; Kusakabe, Kiyoko; Kasanuki, Hiroshi

    2007-01-01

    It has been reported that 123 I-metaiodobenzylguanidine (MIBG) scintigraphy can predict the poor prognosis in patients with dilated cardiomyopathy (DCM). However, the prognostic significance of MIBG is still unknown in patients with other heart diseases. In this study, we compared the prognosis and MIBG findings in various heart diseases. Consecutive 565 patients undergoing MIBG scintigraphy were enrolled (392 men, 52±16 years). Indications were that 127 had ischemic heart disease (IHD), 120 DCM, 101 hypertrophic cardiomyopathy (HCM), 21 hypertensive heart disease (HHD), 58 volume-load valvular disease (VVD), 38 pressure-load valvular disease (PVD), and 101 ventricular tachycardia or fibrillation (VTF). Heart-to-mediastinum ratio (H/M) and washout rate (WR) of MIBG were evaluated. Cardiac events were defined as sudden cardiac death, heart failure, and acute ischemic event (follow-up, 22.7±17.0 months). A total of 106 cardiac events including 40 cardiac deaths occurred. Cox hazard model analysis showed that in the IHD, HCM, and DCM groups, H/M and WR were associated with cardiac death, but not in the HHD, PVD, VVD, or VTF groups. Only death and congestive heart failure (CHF) episodes were related to H/M and WR. On the other hand, fatal arrhythmia, myocardial infarction, or angina pectoris were not related to H/M and WR. The data indicated that WR or H/M may predict death and CHF but does not predict fatal arrhythmia or acute ischemic event. MIBG WR and H/M were associated with heart failure, sudden death, and cardiac death events, and were useful to predict the prognosis in DCM, HCM, and IHD. In contrast, fatal arrhythmia events were not associated with MIBG indices, and thus it does not appear to be useful in predicting cardiac events in patients with VTF. (author)

  1. Cardiac I123-MIBG Correlates Better than Ejection Fraction with Symptoms Severity in Systolic Heart Failure

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, Sandra M.; Moscavitch, Samuel D.; Carestiato, Larissa R. [Programa de Pós-Graduação em Ciências Cardiovasculares, Hospital Universitário Antonio Pedro, Universidade Federal Fluminense, Rio de Janeiro, RJ (Brazil); Felix, Renata M. [Departamento de Medicina Nuclear, Hospital Pró-Cardíaco, Rio de Janeiro, RJ (Brazil); Rodrigues, Ronaldo C.; Messias, Leandro R. [Programa de Pós-Graduação em Ciências Cardiovasculares, Hospital Universitário Antonio Pedro, Universidade Federal Fluminense, Rio de Janeiro, RJ (Brazil); Azevedo, Jader C. [Programa de Pós-Graduação em Ciências Cardiovasculares, Hospital Universitário Antonio Pedro, Universidade Federal Fluminense, Rio de Janeiro, RJ (Brazil); Departamento de Medicina Nuclear, Hospital Pró-Cardíaco, Rio de Janeiro, RJ (Brazil); Nóbrega, Antonio Cláudio L.; Mesquita, Evandro Tinoco [Programa de Pós-Graduação em Ciências Cardiovasculares, Hospital Universitário Antonio Pedro, Universidade Federal Fluminense, Rio de Janeiro, RJ (Brazil); Mesquita, Claudio Tinoco, E-mail: ctinocom@cardiol.br [Programa de Pós-Graduação em Ciências Cardiovasculares, Hospital Universitário Antonio Pedro, Universidade Federal Fluminense, Rio de Janeiro, RJ (Brazil); Departamento de Medicina Nuclear, Hospital Pró-Cardíaco, Rio de Janeiro, RJ (Brazil)

    2013-07-15

    The association of autonomic activation, left ventricular ejection fraction (LVEF) and heart failure functional class is poorly understood. Our aim was to correlate symptom severity with cardiac sympathetic activity, through iodine-123-metaiodobenzylguanidine ({sup 123}I-MIBG) scintigraphy and with LVEF in systolic heart failure (HF) patients without previous beta-blocker treatment. Thirty-one patients with systolic HF, class I to IV of the New York Heart Association (NYHA), without previous beta-blocker treatment, were enrolled and submitted to {sup 123}I-MIBG scintigraphy and to radionuclide ventriculography for LVEF determination. The early and delayed heart/mediastinum (H/M) ratio and the washout rate (WR) were performed. According with symptom severity, patients were divided into group A, 13 patients in NYHA class I/II, and group B, 18 patients in NYHA class III/IV. Compared with group B patients, group A had a significantly higher LVEF (25% ± 12% in group B vs. 32% ± 7% in group A, p = 0.04). Group B early and delayed H/M ratios were lower than group A ratios (early H/M 1.49 ± 0.15 vs. 1.64 ± 0.14, p = 0.02; delayed H/M 1.39 ± 0.13 vs. 1.58 ± 0.16, p = 0.001, respectively). WR was significantly higher in group B (36% ± 17% vs. 30% ± 12%, p= 0.04). The variable that showed the best correlation with NYHA class was the delayed H/M ratio (r= -0.585; p=0.001), adjusted for age and sex. This study showed that cardiac {sup 123}I-MIBG correlates better than ejection fraction with symptom severity in systolic heart failure patients without previous beta-blocker treatment.

  2. The clinical value of cardiac sympathetic imaging in heart failure

    DEFF Research Database (Denmark)

    Christensen, Thomas Emil; Kjaer, Andreas; Hasbak, Philip

    2014-01-01

    The autonomic nervous system plays an important role in the pathology of heart failure. The single-photon emission computed tomography tracer iodine-123-metaiodobenzylguanidine ((123) I-MIBG) can be used to investigate the activity of the predominant neurotransmitter of the sympathetic nervous...

  3. Physiological changes in human cardiac sympathetic innervation and activity assessed by 123I-metaiodobenzylguanidine (MIBG) imaging

    International Nuclear Information System (INIS)

    Sakata, Kazuyuki; Iida, Kei; Mochizuki, Nao; Ito, Michitoshi; Nakaya, Yoshihiro

    2009-01-01

    Physiologic changes in the human sympathetic nervous system (SNS) may be associated with cardiovascular diseases, so the present study assessed the age and gender differences in global cardiac SNS in normal subjects. The 163 subjects (74 men, 89 women; age range 40-89 years) whose coronary arteriogram was normal, and who had no other cardiac or neurohormonal diseases, and no medication affecting the autonomic nervous system were included. All study subjects underwent metaiodobenzylguanidine imaging. Both initial and delayed heart-to-mediastinum (H/M) ratios had a significant gender difference and showed a progressive decrease with aging. In addition, the initial H/M ratio had a significant positive correlation with the delayed H/M ratio (r=0.89, P<0.0001). Females (50-59 years) demonstrated significantly higher delayed H/M ratio than males of the same age. After the age of 60, the delayed H/M ratio in females progressively decreased with aging, similar to males. As for the washout rate, both genders had a significantly progressive increase with aging. In addition, there was a significant decrease in the delayed H/M ratio in 10 females with surgical menopause compared with 15 age-matched females without surgical menopause. Cardiac SNS appears to be regulated by various physiological factors. (author)

  4. Development and validation of a direct-comparison method for cardiac {sup 123}I-metaiodobenzylguanidine washout rates derived from late 3-hour and 4-hour imaging

    Energy Technology Data Exchange (ETDEWEB)

    Okuda, Koichi; Hashimoto, Mitsumasa [Kanazawa Medical University, Department of Physics, Kahoku, Ishikawa (Japan); Nakajima, Kenichi; Matsuo, Shinro; Taki, Junichi; Kinuya, Seigo [Kanazawa University Hospital, Department of Nuclear Medicine, Kanazawa, Ishikawa (Japan); Sugino, Shuichi [Okayama Kyokuto Hospital, Department of Radiology, Okayama, Okayama (Japan); Kirihara, Yumiko [FUJIFILM RI Pharma Co., Ltd., Chuo-Ku, Tokyo (Japan)

    2016-02-15

    The washout rate (WR) has been used in {sup 123}I-metaiodobenzylguanidine (MIBG) imaging to evaluate cardiac sympathetic innervation. However, WR varies depending on the time between the early and late MIBG scans. Late scans are performed at either 3 or 4 hours after injection of MIBG. The aim of this study was to directly compare the WR at 3 hours (WR{sub 3h}) with the WR at 4 hours (WR{sub 4h}). We hypothesized that the cardiac count would reduce linearly between the 3-hour and 4-hour scans. A linear regression model for cardiac counts at two time-points was generated. We enrolled a total of 96 patients who underwent planar {sup 123}I-MIBG scintigraphy early (15 min) and during the late phase at both 3 and 4 hours. Patients were randomly divided into two groups: a model-creation group (group 1) and a clinical validation group (group 2). Cardiac counts at 15 minutes (count{sub early}), 3 hours (count{sub 3h}) and 4 hours (count{sub 4h}) were measured. Cardiac count{sub 4h} was mathematically estimated using the linear regression model from count{sub early} and count{sub 3h}. In group 1, the actual cardiac count{sub 4h}/count{sub early} was highly significantly correlated with count{sub 3h}/count{sub early} (r = 0.979). In group 2, the average estimated count{sub 4h} was 92.8 ± 31.9, and there was no significant difference between this value and the actual count{sub 4h} (91.9 ± 31.9). Bland-Altman analysis revealed a small bias of -0.9 with 95 % limits of agreement of -6.2 and +4.3. WR{sub 4h} calculated using the estimated cardiac count{sub 4h} was comparable to the actual WR{sub 4h} (24.3 ± 9.6 % vs. 25.1 ± 9.7 %, p = ns). Bland-Altman analysis and the intraclass correlation coefficient showed that there was excellent agreement between the estimated and actual WR{sub 4h}. The linear regression model that we used accurately estimated cardiac count{sub 4h} using count{sub early} and count{sub 3h}. Moreover, WR{sub 4h} that was mathematically calculated using

  5. Effects of aldose reductase inhibitor and vitamin B12 on myocardial uptake of iodine-123 metaiodobenzylguanidine in patients with non-insulin-dependent diabetes mellitus

    International Nuclear Information System (INIS)

    Utsunomiya, Keita; Narabayashi, Isamu; Tamura, Koji; Nakatani, Yuko; Saika, Yoshinori; Onishi, Satoshi; Kariyone, Shigeo

    1998-01-01

    This study was undertaken to examine the effects of aldose reductase inhibitor (ARI) and vitamin B 12 (VB12) on myocardial uptake of iodine-123 metaiodobenzylguanidine (MIBG) in patients with diabetic autonomic disorder. Myocardial scintigraphy using 123 I-MIBG was performed on 20 healthy volunteers (controls) and 56 patients with non-insulin-dependent diabetes mellitus (NIDDM), in order to obtain the heart/mediastinum ratio in the initial (HMi) and the delayed images (HMd), and the washout rate (%WR). Thirty-four of the 56 NIDDM patients could be diagnosed as having diabetic autonomic disorder by evaluating their scintigraphic findings in comparison with the controls. Seventeen of these 34 patients received 150 mg/day of epalrestat (ARI group) in three divided doses before meals, and the other 17 received 1.5 mg/day of mecobalamin (VB12 group) in three divided doses after meals, for 3-5 months. According to the presence or absence of clinical symptoms of autonomic or peripheral somatic nerve disorder, the patients were subclassified into four groups. group 1=patients, with autonomic symptoms or somatosensory disorder in the ARI group; group 2=patients without autonomic symptoms or somatosensory disorder in the ARI group; group 3=patients with autonomic symptoms or somatosensory disorder in the VB12 group; and group 4=patients without autonomic symptoms or somatosensory disorder in the VB12 group. After completion of the treatment, myocardial scintigraphy was performed again. Comparing the results obtained before and after the treatment, it was seen that ARI improved only the HMi in group 1 (P=0.046), whereas VB12 significantly improved HMi in the group 3 (P=0.018) and HMi, HMd and %WR in group 4 (P=0.043, P=0.018 and P=0.043, respectively). We conclude that VB12 is more efficacious than ARI in the treatment of diabetic cardiovascular autonomic disorder. (orig.)

  6. Cardiac 123I-MIBG uptake in de novo Brazilian patients with Parkinson's disease without clinically defined dysautonomia

    Directory of Open Access Journals (Sweden)

    Marco Antonio Araujo Leite

    2014-06-01

    Full Text Available Myocardial scintigraphy with meta-iodo-benzyl-guanidine (123I cMIBG has been studied in Parkinson's disease (PD, especially in Asian countries, but not in Latin America. Most of these studies include individuals with PD associated to a defined dysautonomia. Our goal is to report the cardiac sympathetic neurotransmission in de novo Brazilian patients with sporadic PD, without clinically defined dysautonomia. We evaluated retrospectively a series of 21 consecutive cases with PD without symptoms or signs of dysautonomia assessed by the standard bedside tests. This number was reduced to 14 with the application of exclusion criteria. 123I cMIBG SPECT up-take was low or absent in all of them and the heart/mediastinum ratio was low in 12 of 14. We concluded that 123I cMIBG has been able to identify cardiac sympathetic neurotransmission disorder in Brazilian de novo PD patients without clinically defined dysautonomia.

  7. The development of iodine-123-methyl-branched fatty acids and their applications in nuclear cardiology

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, F.F. Jr.; Ambrose, K.R. [Oak Ridge National Lab., TN (United States); Kropp, J.; Biersack, H.J. [Bonn Univ. (Germany). Inst. fuer Klinische und Experimentelle Nuklearmedizin; Goodman, M.M. [University of Tennessee Medical Center, Knoxville, TN (United States). Dept. of Radiology; Franken, P. [Free Univ. Hospital, Brussels (Belgium). Nuclear Medicine Dept.; Reske, S.N. [Ulm Univ. (Germany). Sektion Nuklearmedizin; Som, P. [Brookhaven National Lab., Upton, NY (United States); Sloof, G.W.; Visser, F.C. [Free Univ. Hospital, Amsterdam (Netherlands). Cardiology Dept.

    1993-06-01

    Continued Interest in the use of iodine-1 23-labeled fatty acids for myocardial Imaging results from observations from a variety of studies that in many types of cardiac disease, regional fatty acid myocardial uptake patterns are often different than regional distribution of flow tracers. These differences may reflect alterations in important parameters of metabolism which can be useful for patient management or therapeutic strategy decision making. In addition, use of iodine-I 23-labeled fatty acid distribution may represent a unique metabolic probe to relate some aspects of the metabolism of these substrates with the regional viability of cardiac tissue. The use of such viability markers could provide important prognostic information on myocardial salvage, helping to identify patients for revascularization or angioplasty. Clinical studies are currently in progress with the iodine-123-labeled 1 5-(p-iodophenyl)-3-R,S-methylpentadecanoic acid (BMIPP) fatty acid analogue at several institutions. The goals of this paper are to discuss development of the concept of metabolic trapping of fatty acids, to briefly review development and evaluation of various radioiodinated methyl-branched fatty acids and to discuss recent patient studies with iodine-123 (BMIPP) using single photon emission computerized tomography (SPECT).

  8. The development of iodine-123-methyl-branched fatty acids and their applications in nuclear cardiology

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, F.F. Jr.; Ambrose, K.R. (Oak Ridge National Lab., TN (United States)); Kropp, J.; Biersack, H.J. (Bonn Univ. (Germany). Inst. fuer Klinische und Experimentelle Nuklearmedizin); Goodman, M.M. (University of Tennessee Medical Center, Knoxville, TN (United States). Dept. of Radiology); Franken, P. (Free Univ. Hospital, Brussels (Belgium). Nuclear Medicine Dept.); Reske, S.N. (Ulm Univ. (Germany

    1993-01-01

    Continued Interest in the use of iodine-1 23-labeled fatty acids for myocardial Imaging results from observations from a variety of studies that in many types of cardiac disease, regional fatty acid myocardial uptake patterns are often different than regional distribution of flow tracers. These differences may reflect alterations in important parameters of metabolism which can be useful for patient management or therapeutic strategy decision making. In addition, use of iodine-I 23-labeled fatty acid distribution may represent a unique metabolic probe to relate some aspects of the metabolism of these substrates with the regional viability of cardiac tissue. The use of such viability markers could provide important prognostic information on myocardial salvage, helping to identify patients for revascularization or angioplasty. Clinical studies are currently in progress with the iodine-123-labeled 1 5-(p-iodophenyl)-3-R,S-methylpentadecanoic acid (BMIPP) fatty acid analogue at several institutions. The goals of this paper are to discuss development of the concept of metabolic trapping of fatty acids, to briefly review development and evaluation of various radioiodinated methyl-branched fatty acids and to discuss recent patient studies with iodine-123 (BMIPP) using single photon emission computerized tomography (SPECT).

  9. Usefulness of cardiac 123I-MIBG imaging for the evaluation of diastolic heart failure

    International Nuclear Information System (INIS)

    Tanaka, Haruki; Kozai, Toshiyuki; Urabe, Yoshitoshi

    2007-01-01

    Significance of 123 I-MIBG (metaiodobenzylguanidine) scintigraphy in diagnosis of cardiac sympathetic nerve function is not yet elucidated in chronic heart failure derived from left ventricular diastolic defect despite its established importance in evaluation of severity and prognosis of chronic systolic heart failure. This study was performed to elucidate the usefulness of the imaging for chronic diastolic heart failure. Comparison was made of 47 hospitalized patients with chronic diastolic heart failure (D-group; left ejection fraction, 50% or more), 45 with chronic systolic failure (S-group; the fraction 123 I-MIBG with 2-detector gamma camera (Toshiba E.CAM), of which images were analyzed by Toshiba GMS-7000. Cardiac sympathetic nerve function in D-group was found stimulated to be impaired, in a similar extent to that in S-group; severity in NYHA classification was significantly correlated with late H/M ratio and WR; WR in cases with atrial fibrillation complication showed a significant correlation with plasma BNP level; and 123 I-MIBG scintigraphic evaluation of the nerve function in D-group was concluded to be useful for severity assessment. (T.I.)

  10. Alteration of myocardial metaiodobenzylguanidine uptake after treatment of phaeochromocytoma and neuroblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Suga, Kazuyoshi; Ogasawara, Nobuhiko; Ariga, Misako; Motoyama, Kazumi; Hara, Akiko; Kume, Norihiko; Matsunaga, Naofumi [Department of Radiology, Yamaguchi University School of Medicine, Ube, Yamaguchi (Japan)

    2000-05-01

    The relationships between changes in myocardial uptake of metaiodobenzylguanidine (MIBG) and those in circulating catecholamines and cardiac function after treatment of phaeochromocytoma and neuroblastoma were evaluated. Iodine-123 or iodine-131 MIBG scintigraphy was performed before and after surgical resection and/or chemotherapy for primary tumours in nine patients with phaeochromocytoma and 13 patients with neuroblastoma. Changes in myocardial MIBG uptake after treatment were estimated by the heart-to-upper mediastinum (H/M) uptake ratios on the images obtained 24 h after MIBG injection, which were compared with serum levels of noradrenaline (NA) and adrenaline (A). Cardiac function was assessed by echocardiography, with measurements of the left ventricular ejection fraction (LVEF). Before treatment, eight patients with phaeochromocytoma and three with neuroblastoma showed poor myocardial MIBG uptake, with highly elevated circulating NA and A. Echocardiography, however, did not show cardiac dysfunction in these patients with the exception of two patients with phaeochromocytoma. With normalization of NA and A levels after treatment, all of these patients except for the two with persistent cardiac dysfunction showed restoration of myocardial MIBG uptake. The H/M ratios increased significantly after treatment in both patient groups, i.e. with phaeochromocytoma and with neuroblastoma (P<0.0001 and P<0.05, respectively), and these ratios correlated inversely with circulating NA and A before and after treatment. By contrast, there was no significant correlation between H/M ratios and LVEF in these two groups. These results indicate that suppression of myocardial MIBG uptake usually may not be related to cardiac dysfunction and may be reversible following normalization of excess catecholamine levels after treatment in patients with neuroadrenergic tumours. However, the suppression may persist in the presence of catecholamine-induced cardiac dysfunction. The assessment

  11. Metaiodobenzylguanidine and heart rate variability in heart failure

    International Nuclear Information System (INIS)

    Kurata, Chinori; Shouda, Sakae; Mikami, Tadashi; Uehara, Akihiko; Ishikawa, Keiko; Tawarahara, Kei; Nakano, Tomoyasu; Matoh, Fumitaka; Takeuchi, Kazuhiko

    1998-01-01

    It is assumed that the low-frequency power (LF) of heart rate variability (HRV) increases with progress of congestive heart failure (CHF), therefore positively correlating with cardiac 123 I-metaiodobenzylguanidine (MIBG) washout. It is demonstrated here that HRV, including normalized LF, correlated inversely with MIBG washout and positively with the ratio of heart-to-mediastinum MIBG activity in controls and CHF patients, whereas these correlations were not observed within CHF patients. Thus MIBG washout may increase and HRV including normalized LF may decrease with CHF, although the HRV and MIBG measures may not similarly change in proportion to the severity of the cardiac autonomic dysfunction in CHF. (author)

  12. Metaiodobenzylguanidine and heart rate variability in heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Kurata, Chinori; Shouda, Sakae; Mikami, Tadashi; Uehara, Akihiko; Ishikawa, Keiko [Hamamatsu Univ., Shizuoka (Japan). School of Medicine; Tawarahara, Kei; Nakano, Tomoyasu; Matoh, Fumitaka; Takeuchi, Kazuhiko

    1998-10-01

    It is assumed that the low-frequency power (LF) of heart rate variability (HRV) increases with progress of congestive heart failure (CHF), therefore positively correlating with cardiac {sup 123}I-metaiodobenzylguanidine (MIBG) washout. It is demonstrated here that HRV, including normalized LF, correlated inversely with MIBG washout and positively with the ratio of heart-to-mediastinum MIBG activity in controls and CHF patients, whereas these correlations were not observed within CHF patients. Thus MIBG washout may increase and HRV including normalized LF may decrease with CHF, although the HRV and MIBG measures may not similarly change in proportion to the severity of the cardiac autonomic dysfunction in CHF. (author)

  13. Assessment of cardiac neuronal function with iodine-123 MIBG scintigraphy in children with idiopathic dilated cardiomyopathy

    International Nuclear Information System (INIS)

    Maunoury, Ch.; Sebahoun, St.; Hallaj, I.; Barritault, L.; Acar, Ph.; Sidi, D.; Kachaner, J.; Agostini, D.; Bouvard, G.

    2000-01-01

    The I-123 MIBG cardiac scintigraphy can assess norepinephrine uptake. It has been showed that cardiac adrenergic neuronal function was impaired in adults with dilated cardiomyopathy. The aim of this prospective study was to assess cardiac neuronal function in children with idiopathic dilated cardiomyopathy (DCM) and to compare cardiac uptake of I-123 MIBG with left ventricular ejection fraction (LVEF). We studied 26 consecutive patients with idiopathic DCM, aged 44 ± 50 months, and 12 controls, aged 49 ±65 months. A planar scintigraphy was performed in all children 4 hours after intravenous injection of 20 to 75 MBq of I-123 MIBG. A static anterior view was acquired for 10 minutes. Cardiac uptake of I-123 MIBG was expressed as the heart to mediastinum count ratio (HMR). Equilibrium radionuclide angiography was performed following a standard protocol. Cardiac uptake of I-123 MIBG was significantly decreased in patients with idiopathic DCM when compared with cardiac uptake in controls (172±34% vs 277±14%, P<0.0001. There was a good correlation between RCM and LVEF in patients with idiopathic DCM (y = 2.5 x +113.3, r = 0.80, P < 0.0001). In conclusion, cardiac neuronal function was impaired in children with idiopathic DCM and related to impairment of left ventricular function. (author)

  14. Updating the procedure for metaiodobenzylguanidine labelling with iodine radioisotopes employed in industrial production.

    Science.gov (United States)

    Franceschini, R; Mosca, R; Bonino, C

    1991-01-01

    The classical procedure used for the preparation of [125I]- and [131I]metaiodobenzylguanidine (MIBG) is the solid-phase isotopic exchange between MIBG and radioiodide. This reaction requires 1.5 hours at 160 degrees C to obtain maximum total labelling yields of 75-80%. Recently, the importance of rapid procedures for the preparation of 123I-MIBG has been highlighted. A highly efficient procedure for the industrial production of 123I-MIBG using ascorbic acid, tin sulfate and copper sulfate pentahydrate in 0.01 M sulfuric acid is reported. Sequential radio-TLC analysis of the labelling mixture shows that the labelling yield reaches 98% within 45 min at 100 degrees C. The specific activity of the 123I-MIBG produced in this manner is on the order of 100 Ci/mmol.

  15. The development of iodine-123-labeled-methyl-branched fatty acids for myocardial SPECT imaging

    International Nuclear Information System (INIS)

    Knapp, F.F. Jr.; Kropp, J.

    1994-01-01

    Iodine-123-labeled fatty acids represent unique metabolic probes for correlation of energy substrate metabolism with regional myocardial viability. Interest in the use of these agents results from differences which are often observed in various types of heart disease between regional myocardial fatty acid uptake patterns and flow tracer distribution. Although the physiological basis is not completely understood, differences between regional fatty acid and flow tracer distribution may reflect alterations in important parameters of metabolism which can be useful for patient management or therapeutic strategy decision making. The iodine-123-labeled 15-(p-iodophenyl)-3-R,S-methylpentadecanoic acid (BMIPP) fatty acid analogue was developed at the Oak Ridge National Laboratory and was recently introduced as ''Cardiodine trademark'' in 1993 by Nihon Medi-Physics for commercial distribution in Japan. Iodine-123-BMPP is also being used in clinical studies on an institutional approval basis at several institutions in Europe and the US. This paper describes the development of the concept of fatty acid ''metabolic trapping'' of methyl-branched fatty acids and their use for single photon emission computerized tomographic cardiac imaging

  16. False Positive Radioiodinated Metaiodobenzylguanidine (123I-MIBG Uptake in Undifferentiated Adrenal Malignant Tumor

    Directory of Open Access Journals (Sweden)

    Hee Soo Jung

    2015-01-01

    Full Text Available 123I-Metaiodobenzylguanidine (123I-MIBG scintigraphy is a widely used functional imaging tool with a high degree of sensitivity and specificity in diagnosis of pheochromocytoma. However, rare cases of false positive reactions have been reported. A 67-year-old male patient was admitted with epigastric pain. Abdominal computed tomography (CT revealed a heterogeneous left adrenal mass 6 cm in diameter; following hormone testing, 123I-MIBG scintigraphy was performed to determine the presence of pheochromocytoma, which confirmed eccentric uptake by a large left adrenal gland mass. Chest CT and PET-CT confirmed metastatic lymphadenopathy; therefore, endobronchial ultrasound transbronchial needle aspiration was performed. Metastatic carcinoma of unknown origin was suspected from a lymph node biopsy, and surgical resection was performed for definitive diagnosis and correction of excess hormonal secretion. A final diagnosis of undifferentiated adrenal malignant tumor was rendered, instead of histologically malignant pheochromocytoma, despite the uptake of 123I-MIBG demonstrated by scintigraphy.

  17. Focal Reduction in Cardiac 123I-Metaiodobenzylguanidine Uptake in Patients With Anderson-Fabry Disease.

    Science.gov (United States)

    Yamamoto, Saori; Suzuki, Hideaki; Sugimura, Koichiro; Tatebe, Shunsuke; Aoki, Tatsuo; Miura, Masanobu; Yaoita, Nobuhiro; Sato, Haruka; Kozu, Katuya; Ota, Hideki; Takanami, Kentaro; Takase, Kei; Shimokawa, Hiroaki

    2016-11-25

    It remains to be elucidated whether cardiac sympathetic nervous activity is impaired in patients with Anderson-Fabry disease (AFD).Methods and Results:We performed 123 I-meta-iodobenzylguanidine (MIBG) scintigraphy and gadolinium-enhanced cardiovascular magnetic resonance (CMR) in 5 AFD patients. MIBG uptake in the inferolateral wall, where wall thinning and delayed enhancement were noted on CMR, was significantly lower compared with the anteroseptal wall. The localized reduction in MIBG uptake was also noted in 2 patients with no obvious abnormal findings on CMR. Cardiac sympathetic nervous activity is impaired in AFD before development of structural myocardial abnormalities. (Circ J 2016; 80: 2550-2551).

  18. Iodine-123 program at the TRIUMF laboratory

    International Nuclear Information System (INIS)

    Vincent, J.S.

    1985-01-01

    A research program for the production and utilization of iodine-123 is described. From 1979 to 1982 the spallation of elemental cesium by 500-MeV protons was used to provide 100 mCi/hr at the end of bombardment (EOB). Contaminants were 3% iodine-125 and 0.15% tellurium-121 at EOB + 36 hr. The material from weekly runs was used by remote clinics in Canada for evaluation as a radiochemical and for labeling studies. A new facility at TRIUMF will be operational in 1983 to produce iodine-123 by the (p,5n) reaction

  19. {sup 123}I-Labelled metaiodobenzylguanidine for the evaluation of cardiac sympathetic denervation in early stage amyloidosis

    Energy Technology Data Exchange (ETDEWEB)

    Noordzij, Walter; Glaudemans, Andor W.J.M.; Rheenen, Ronald W.J. van; Dierckx, Rudi A.J.O.; Slart, Riemer H.J.A. [University of Groningen, Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, PO Box 30.001, Groningen (Netherlands); Hazenberg, Bouke P.C. [University of Groningen, Department of Rheumatology and Clinical Immunology, University Medical Center Groningen, Groningen (Netherlands); Tio, Rene A. [University of Groningen, Department of Cardiology, University Medical Center Groningen, Groningen (Netherlands)

    2012-10-15

    Cardiac amyloidosis is a rare disorder, but it may lead to potentially life-threatening restrictive cardiomyopathy. Cardiac manifestations frequently occur in primary amyloidosis (AL) and familial amyloidosis (ATTR), but are uncommon in secondary amyloidosis (AA). Echocardiography is the method of choice for assessing cardiac amyloidosis. Amyloid deposits impair the function of sympathetic nerve endings. Disturbance of myocardial sympathetic innervations may play an important role in the remodelling process. {sup 123}I-MIBG can detect these innervation changes. Patients with biopsy-proven amyloidosis underwent general work-up, echocardiography and {sup 123}I-MIBG scintigraphy. Left ventricular internal dimensions and wall thickness were measured, and highly refractile cardiac echoes (sparkling) were analysed. Early (15 min) and late (4 h) heart-to-mediastinum ratio (HMR) and wash-out rate were determined after administration of MIBG. Included in the study were 61 patients (30 women and 31 men; mean age 62 years; 39 AL, 11 AA, 11 ATTR). Echocardiographic parameters were not significantly different between the groups. Sparkling was present in 72 % of ATTR patients, in 54 % of AL patients and in 45 % of AA patients. Mean late HMR in all patients was 2.3 {+-} 0.75, and the mean wash-out rate was 8.6 {+-} 14 % (the latter not significantly different between the patient groups). Late HMR was significantly lower in patients with echocardiographic signs of amyloidosis than in patients without (2.0 {+-} 0.70 versus 2.8 {+-} 0.58, p < 0.001). Wash-out rates were significantly higher in these patients (-3.3 {+-} 9.9 % vs. 17 {+-} 10 %, p < 0.001). In ATTR patients without echocardiographic signs of amyloidosis, HMR was lower than in patients with the other types (2.0 {+-} 0.59 vs. 2.9 {+-} 0.50, p = 0.007). MIBG HMR is lower and wash-out rate is higher in patients with echocardiographic signs of amyloidosis. Also, {sup 123}I-MIBG scintigraphy can detect cardiac denervation in

  20. Usefulness of severe cardiac sympathetic dysfunction to predict the occurrence of rapid atrial fibrillation in patients with Wolff-Parkinson-White syndrome.

    Science.gov (United States)

    Akutsu, Yasushi; Kaneko, Kyouichi; Kodama, Yusuke; Li, Hui-Ling; Asano, Taku; Suyama, Jumpei; Tanno, Kaoru; Namiki, Atsuo; Shinozuka, Akira; Gokan, Takehiko; Kobayashi, Youichi

    2013-09-01

    Atrial fibrillation (AF) can be a potentially life-threatening arrhythmia when it conducts rapidly through the accessory pathway, which was not predicted by the noninvasive method. We evaluated the cardiac sympathetic activity for predicting the occurrence of AF in patients with Wolff-Parkinson-White (WPW) syndrome. Iodine-123 metaiodobenzylguanidine scintigraphy was performed under stable sinus rhythm conditions at rest syndrome than in the normal control group, and in the 15 patients with AF induced during EPS than in the 30 patients without AF (p syndrome. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Validation of cardiac 123I-MIBG scintigraphy in patients with Parkinson's disease who were diagnosed with dopamine PET

    International Nuclear Information System (INIS)

    Ishibashi, Kenji; Saito, Yuko; Murayama, Shigeo; Kanemaru, Kazutomi; Oda, Keiichi; Ishiwata, Kiichi; Ishii, Kenji; Mizusawa, Hidehiro

    2010-01-01

    The aim of this study was to evaluate the diagnostic potential of cardiac 123 I-labelled metaiodobenzylguanidine ( 123 I-MIBG) scintigraphy in idiopathic Parkinson's disease (PD). The diagnosis was confirmed by positron emission tomography (PET) imaging with 11 C-labelled 2β-carbomethoxy-3β-(4-fluorophenyl)-tropane ( 11 C-CFT) and 11 C-raclopride (together designated as dopamine PET). Cardiac 123 I-MIBG scintigraphy and dopamine PET were performed for 39 parkinsonian patients. To estimate the cardiac 123 I-MIBG uptake, heart to mediastinum (H/M) ratios in early and delayed images were calculated. On the basis of established clinical criteria and our dopamine PET findings, 24 patients were classified into the PD group and 15 into the non-PD (NPD) group. Both early and delayed images showed that the H/M ratios were significantly lower in the PD group than in the NPD group. When the optimal cut-off levels of the H/M ratio were set at 1.95 and 1.60 in the early and delayed images, respectively, by receiver-operating characteristic analysis, the sensitivity of cardiac 123 I-MIBG scintigraphy for the diagnosis of PD was 79.2 and 70.8% and the specificity was 93.3 and 93.3% in the early and delayed images, respectively. In the Hoehn and Yahr 1 and 2 PD patients, the sensitivity decreased by 69.2 and 53.8% in the early and delayed images, respectively. In early PD cases, cardiac 123 I-MIBG scintigraphy is of limited value in the diagnosis, because of its relatively lower sensitivity. However, because of its high specificity for the overall cases, cardiac 123 I-MIBG scintigraphy may assist in the diagnosis of PD in a complementary role with the dopaminergic neuroimaging. (orig.)

  2. Experimental and clinical experience with iodine 123-labeled iodophenylpentadecanoic acid in cardiology.

    Science.gov (United States)

    Reske, S N

    1994-01-01

    Iodine 123-labeled iodophenylpentadecanoic acid (IPPA) has been synthesized for investigating myocardial free fatty acid (FFA) metabolism. The diagnostic application of labeled FFA in heart disease may be important, because FFA is the preferred substrate of cardiac energy metabolism at rest in the fasting state. In addition, regional myocardial FFA uptake and regional myocardial blood flow are tightly coupled in normal myocardium with beta-oxidation, which is extremely sensitive to oxygen deprivation. This article outlines basic physiologic pathways of cardiac IPPA metabolism in normal, acutely ischemic, and reperfused viable myocardium and summarizes the results of experimental studies in animals, validating the application of IPPA as an 123I-labeled fatty acid analog. In addition, the most important clinical studies indicating the clinical use of IPPA for diagnosis of coronary heart disease and myocardial viability are presented.

  3. Alternating myocardial sympathetic neural function of athlete's heart in professional cycle racers examined with iodine-123-MIBG myocardial scintigraphy

    International Nuclear Information System (INIS)

    Koyama, Keiko; Inoue, Tomio; Hasegawa, Akira; Oriuchi, Noboru; Okamoto, Eiichi; Tomaru, Yumi; Endo, Keigo

    2001-01-01

    Myocardial sympathetic neural function in professional athletes who had the long-term tremendous cardiac load has not been fully investigated by myocardial iodine-123-metaiodobenzylguanidine (MIBG) uptake in comparison with power spectral analysis (PSA) in electrocardiography. Eleven male professional cycle racers and age-matched 11 male healthy volunteers were enrolled in this study. The low frequency components in the power spectral density (LF), the high frequency components in the power spectral density (HF), the LF/HF ratio and mean R-R interval were derived from PSA and time-domain analysis of heart rate variability in electrocardiography. The mean heart-to-mediastinum uptake ratio (H/M ratio) of the MIBG uptake, in professional cycle racers was significantly lower than that in healthy volunteers (p<0.01) and HF power in professional cycle racers was significantly higher than that in healthy volunteers (p<0.05). In the group of professional cycle racers, the H/M ratio showed a significant correlation with the R-R interval, as indices of parasympathetic nerve activity (r=0.80, p<0.01), but not with the LF/HF ratio as an index of sympathetic nerve activity. These results may indicate that parasympathetic nerve activity has an effect on MIBG uptake in a cyclist's heart. (author)

  4. Asymmetry of salivary gland I123 Metaiodobenzylguanidine (MIBG) uptake in a patient with cervical neuroblastoma and Horner's syndrome - possible etiologic mechanisms

    International Nuclear Information System (INIS)

    Sandler, E.D.; Hattner, R.S.; Parisi, M.T.

    1992-01-01

    Horner's syndrome may be due to a variety of serious underlying disorders including cervical neuroblastoma. Horner's syndrome results from a unilateral disruption of the sympathetic innervation to the head and neck. We report a patient with cervical neuroblastoma in whom post operative metaiodobenzylguanidine (MIBG) scans showed a striking decrease in uptake in the ipselateral salivary glands. Since the biodistribution of I 123 metaiodobenzylguanidine in the salivary glands is also dependent on sympathetic innervation, the presence of Horner's syndrome can be reflected in the MIBG scan. (orig.)

  5. Impaired cardiac uptake of meta-[123I]iodobenzylguanidine in Parkinson's disease with autonomic failure

    International Nuclear Information System (INIS)

    Braune, S.; Luecking, C.H.; Reinhardt, M.; Bathmann, J.; Krause, T.; Lehmann, M.

    1998-01-01

    Objective - To selectively investigate postganglionic sympathetic cardiac neurons in patients with Parkinson's disease and autonomic failure. Material and methods - Metaiodobenzylguanidine (MIBG) is a pharmacologically inactive analogue of noradrenaline, which is similarly metabolized in noradrenergic neurons. Therefore the uptake of radiolabelled MIBG represents not only the localization of postganglionic sympathetic neurons but also their functional integrity. Ten patients with Parkinson's disease and autonomic failure underwent standardized autonomic testing, assessment of catecholamine plasma levels and scintigraphy with [ 123 I]MIGB. Results - The cardiac uptake of MIBG, as demonstrated by the heart/mediastinum ratio, was significantly lower in patients in comparison with controls. Scintigraphy with MIBG allowed the selective in-vivo investigation of postganglionic sympathetic cardiac efferent in patients with autonomic failure, a procedure which was previously confined to post-mortem examination. Conclusion - These findings point to a relevant postganglionic pattern of involvement of the autonomic nervous system (ANS) in Parkinson's disease and autonomic failure. (au)

  6. Cardiac 123I-MIBG scintigraphy in patients with Parkinson's disease

    International Nuclear Information System (INIS)

    Orimo, Satoshi

    1997-01-01

    We discuss the cardiac 123 I-MIBG ( 123 I-metaiodobenzylguanidine) scintigraphy in patients with Parkinson's disease (PD) based on our results, and examine the clinical significance in lowering MIBG storage. Thirty-four patients with PD without diabetes millitus or heart failure, presenting normal cardiac thallium scintigraphy, were examined. They included 13 male and 21 female, aged from 52 to 83 (average age 70.1) and their morbid period was between 0.25 and 19 years (agerage 4.9 years). Ten patients with age-matched disease control were chosen. They contained 5 male and 5 female, aged from 59 to 77 (average age 70.7), suffering from headache, vertigo, cerebral infarction, etc. PD patients group and the age-matched control group were compared with the normal control group. In PD patients, MIBG storage was significantly lowered on the initial and the late images in comparison with the disease and neurological control groups, and the wash-out rate was enhanced. There was negative correlation or the expected tendency of correlation between MIBG storage and the clinical severity. MIBG storage was lowered with longer morbid period. Anti-Parkinson drugs had no apparent effects on MIBG storage. The detection rate of abnormality by cardiac MIBG scintigraphy was clearly higher than that by the sympathetic skin response, and some patients who had no sign on the sympathetic skin response showed the lowering of MIBG storage. The possibility of the failure of the norepinephrine transporter system was indicated as the main cause for the lowering of MIBG storage. (K.H.)

  7. Meta-iodobenzylguanidine scintigraphy in neuroblastoma--a comparison with conventional X-ray and ultrasound

    International Nuclear Information System (INIS)

    Mueller-Gaertner, H.W.Er.; Erttmann, R.; Helmke, K.

    1986-01-01

    To evaluate the accuracy of meta-iodobenzylguanidine (MIBG) imaging in comparison with bone X-ray and ultrasound, 15 patients with histologically verified neuroblastoma were investigated using 123- or 131MIBG scintigraphy. 123MIBG and 131MIBG are used as the abbreviations for 123-iodine-labeled-MIBG and 131-iodine-labeled-MIBG, respectively. Either 7.4 MBq 131MIBG (n = 4) or 111-185 MBq 123MIBG (n = 11) was applied, and scans were performed 24 and 48 h PI. Anatomical orientation was provided in selected cases by single-photon emission CT or scintigraphy of other organs. X-ray procedures or ultrasound depicted 27 neuroblastoma manifestations (primary tumors and metastatic deposits); 24 of these (89%) were identified by MIBG scintigraphy. Of 42 primary neuroblastomas and metastatic deposits, 27 (64%) were detected by corresponding bone X-ray or ultrasound. The 15 neuroblastoma lesions depicted solely by MIBG scans were mainly (80%) situated in the skeletal system. Because of the pronounced physiological MIBG uptake by liver tissue, detection of intrahepatic or perihepatic tumor involvement is difficult. MIBG scintigraphy is a safe and noninvasive means of locating a wide range of neuroblastoma lesions. Its main diagnostic advantage in comparison with bone X-ray lies in the detection of bone marrow infiltration

  8. Ongoing myocardial damage relates to cardiac sympathetic nervous disintegrity in patients with heart failure

    International Nuclear Information System (INIS)

    Arimoto, Takanori; Takeishi, Yasuchika; Niizeki, Takeshi

    2005-01-01

    Iodine-123-metaiodobenzylguanidine ( 123 I-MIBG) has been used to assess the integrity and function of the cardiac sympathetic nervous system in patients with heart failure. Heart-type fatty acid binding protein (H-FABP) is released into the circulation when the myocardium is injured, and H-FABP has been recently used as a novel marker for the diagnosis of ongoing myocardial damage. The aim of the present study was to compare cardiac sympathetic nervous activity assessed by 123 I-MIBG imaging with serum levels of H-FABP in patients with heart failure. Fifty patients with chronic heart failure were studied. 123 I-MIBG imaging was carried out at 30 min (early) and 240 min (delayed) after the tracer injection. We measured serum levels of H-FABP using a sandwich enzyme linked immunosorbent assay. Heart to mediastinum (H/M) ratios of 123 I-MIBG decreased and washout rate increased with higher New York Heart Association (NYHA) functional class. H-FABP, norepinephrine and brain natriuretic peptide (BNP) levels increased as the severity of NYHA class advanced. Delayed H/M ratio was significantly correlated with H-FABP (r=-0.296, p=0.029) and BNP (r=-0.335, p=0.0213). Myocardial washout rate of 123 I-MIBG was also correlated with H-FABP (r=0.469, p 123 I-MIBG imaging is an appropriate approach to evaluate non-invasively not only cardiac sympathetic nervous activity, but also latent ongoing myocardial damage in the failing heart. (author)

  9. Alterations of left ventricular deformation and cardiac sympathetic derangement in patients with systolic heart failure: a 3D speckle tracking echocardiography and cardiac {sup 123}I-MIBG study

    Energy Technology Data Exchange (ETDEWEB)

    Leosco, Dario; Parisi, Valentina; Pagano, Gennaro; Femminella, Grazia Daniela; Bevilacqua, Agnese; Formisano, Roberto; Ferro, Gaetana; De Lucia, Claudio; Ferrara, Nicola [University Federico II, Department of Translational Medical Science, Naples (Italy); Pellegrino, Teresa [Italian National Research Council (CNR), Institute of Biostructure and Bioimaging, Naples (Italy); University Federico II, Department of Advanced Biomedical Science, Naples (Italy); Paolillo, Stefania [University Federico II, Department of Advanced Biomedical Science, Naples (Italy); SDN Foundation, Institute of Diagnostic and Nuclear Development, Naples (Italy); Prastaro, Maria; Filardi, Pasquale Perrone; Cuocolo, Alberto [University Federico II, Department of Advanced Biomedical Science, Naples (Italy); Rengo, Giuseppe [University Federico II, Department of Translational Medical Science, Naples (Italy); Salvatore Maugeri Foundation, IRCCS, Istituto di Telese, Benevento, BN (Italy)

    2015-09-15

    Myocardial contractile function is under the control of cardiac sympathetic activity. Three-dimensional speckle tracking echocardiography (3D-STE) and cardiac imaging with {sup 123}I-metaiodobenzylguanidine ({sup 123}I-MIBG) are two sophisticated techniques for the assessment of left ventricular (LV) deformation and sympathetic innervation, respectively, which offer important prognostic information in patients with heart failure (HF). The purpose of this investigation was to explore, in patients with systolic HF, the relationship between LV deformation assessed by 3D-STE and cardiac sympathetic derangement evaluated by {sup 123}I-MIBG imaging. We prospectively studied 75 patients with systolic HF. All patients underwent a 3D-STE study (longitudinal, circumferential, area and radial) and {sup 123}I-MIBG planar and SPECT cardiac imaging. 3D-STE longitudinal, circumferential and area strain values were correlated with {sup 123}I-MIBG late heart to mediastinum (H/M) ratio and late SPECT total defect score. After stratification of the patients according to ischaemic or nonischaemic HF aetiology, we observed a good correlation of all 3D-STE measurements with late H/M ratio and SPECT data in the ischaemic group, but in patients with HF of nonischaemic aetiology, no correlation was found between LV deformation and cardiac sympathetic activity. At the regional level, the strongest correlation between LV deformation and adrenergic innervation was found for the left anterior descending coronary artery distribution territory for all four 3D-STE values. In multivariate linear regression analyses, including age, gender, LV ejection fraction, NYHA class, body mass index, heart rate and HF aetiology, only 3D-STE area and radial strain values significantly predicted cardiac sympathetic derangement on {sup 123}I-MIBG late SPECT. This study indicated that 3D-STE measurements are correlated with {sup 123}I-MIBG planar and SPECT data. Furthermore, 3D-STE area and radial strain values

  10. Validation of cardiac {sup 123}I-MIBG scintigraphy in patients with Parkinson's disease who were diagnosed with dopamine PET

    Energy Technology Data Exchange (ETDEWEB)

    Ishibashi, Kenji [Tokyo Medical and Dental University, Department of Neurology and Neurological Science, Graduate School, Tokyo (Japan); Tokyo Metropolitan Institute of Gerontology, Positron Medical Center, Tokyo (Japan); Saito, Yuko [Tokyo Metropolitan Geriatric Hospital, Department of Pathology, Tokyo (Japan); Tokyo Metropolitan Institute of Gerontology, Department of Neuropathology, Tokyo (Japan); Murayama, Shigeo [Tokyo Metropolitan Institute of Gerontology, Department of Neuropathology, Tokyo (Japan); Kanemaru, Kazutomi [Tokyo Metropolitan Geriatric Hospital, Department of Neurology, Tokyo (Japan); Oda, Keiichi; Ishiwata, Kiichi; Ishii, Kenji [Tokyo Metropolitan Institute of Gerontology, Positron Medical Center, Tokyo (Japan); Mizusawa, Hidehiro [Tokyo Medical and Dental University, Department of Neurology and Neurological Science, Graduate School, Tokyo (Japan)

    2010-01-15

    The aim of this study was to evaluate the diagnostic potential of cardiac {sup 123}I-labelled metaiodobenzylguanidine ({sup 123}I-MIBG) scintigraphy in idiopathic Parkinson's disease (PD). The diagnosis was confirmed by positron emission tomography (PET) imaging with {sup 11}C-labelled 2{beta}-carbomethoxy-3{beta}-(4-fluorophenyl)-tropane ({sup 11}C-CFT) and {sup 11}C-raclopride (together designated as dopamine PET). Cardiac {sup 123}I-MIBG scintigraphy and dopamine PET were performed for 39 parkinsonian patients. To estimate the cardiac {sup 123}I-MIBG uptake, heart to mediastinum (H/M) ratios in early and delayed images were calculated. On the basis of established clinical criteria and our dopamine PET findings, 24 patients were classified into the PD group and 15 into the non-PD (NPD) group. Both early and delayed images showed that the H/M ratios were significantly lower in the PD group than in the NPD group. When the optimal cut-off levels of the H/M ratio were set at 1.95 and 1.60 in the early and delayed images, respectively, by receiver-operating characteristic analysis, the sensitivity of cardiac {sup 123}I-MIBG scintigraphy for the diagnosis of PD was 79.2 and 70.8% and the specificity was 93.3 and 93.3% in the early and delayed images, respectively. In the Hoehn and Yahr 1 and 2 PD patients, the sensitivity decreased by 69.2 and 53.8% in the early and delayed images, respectively. In early PD cases, cardiac {sup 123}I-MIBG scintigraphy is of limited value in the diagnosis, because of its relatively lower sensitivity. However, because of its high specificity for the overall cases, cardiac {sup 123}I-MIBG scintigraphy may assist in the diagnosis of PD in a complementary role with the dopaminergic neuroimaging. (orig.)

  11. Diagnosis of pheochromocytoma using (123I)-compared with (131I)-metaiodobenzylguanidine scintigraphy

    International Nuclear Information System (INIS)

    Furuta, Nozomu; Kiyota, Hiroshi; Yoshigoe, Fukuo; Hasegawa, Norio; Ohishi, Yukihiko

    1999-01-01

    Patient with pheochromocytoma (PCT) cannot be cured without operation, therefore, preoperative determination of the localization of PCT should be performed accurately. ( 131 I)-Metaiodobenzylguanidine (MIBG) scintigraphy is a gold standard for the diagnosis of PCT. However, ( 123 I)-MIBG is also found to accumulate in PCT. In order to clarify the usefulness of ( 123 I)-MIBG scintigraphy for the local detection of PCT, we compared the distribution of ( 123 I)- and ( 131 I)-MIBG in patients with or without PCT. ( 131 I)- and ( 123 I)-MIBG scintigraphy was performed in 29 and 16 patients, respectively. In the former group, 14 patients had PCT, 12 had hypertension without any adrenal disorder and three had other diseases. In the latter group, eight patients had PCT, two had hypertension without any adrenal disorder and six had other diseases. The sensitivity, specificity and accuracy of ( 123 I)- with ( 131 I)-MIBG scintigraphy were compared. The sensitivity of ( 131 I)- and ( 123 I)-MIBG scintigraphy was 85.7 and 90%, respectively. The specificity of each test was 100%. The accuracy of ( 131 I)- and ( 123 I)-MIBG scintigraphy was 93.1 and 95%, respectively. The quality of images obtained using ( 123 I)-MIBG was better than with ( 131 I)-MIBG, because ( 123 I)-MIBG generated a higher dose of γ-rays with a higher specificity than ( 131 I)-MIBG. In addition, normal adrenal grands were visualized in 50% of patients tested with ( 123 I)-MIBG scintigraphy. These results indicate that ( 123 I)-MIBG scintigraphy is a valuable tool for the local detection of PCT, as is ( 131 I)-MIBG scintigraphy. Furthermore, it is possible that ( 123 I)-MIBG can be used as an alternative to ( 131 I)-MIBG for the detection of PCT. Our study was not a prospective study and the background of the patients was not matched. Further prospective studies are needed in order to determine the efficacy of ( 123 I)-MIBG scintigraphy for the diagnosis of PCT. (author)

  12. Quantitative analysis of 123I-metaiodobenzylguanidine myocardial scintigraphy by myocardial uptake using a phantom

    International Nuclear Information System (INIS)

    Momose, Mitsuru; Kobayashi, Hideki; Kashikura, Kenichi; Kanaya, Shinichi; Maki, Masako; Hosoda, Saichi; Kusakabe, Kiyoko

    1994-01-01

    To evaluate the quantitative analysis of 123 I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy, total injected dose measured by first pass (FP) method (T FP ) was compared with that measured by phantom method using an acrylic phantom in 45 patients with cardiac disease. Heart per mediastinum ratio (H/M) was compared to myocardial uptake calculated with T FP . The total injected dose measured using the phantom in which the syringe was set in depth of 3.5 cm (T pham ) was correlated with T FP (r=0.73, p=0.0001). When T pham was corrected by body weight (c-T pham ), c-T pham showed better correlation with T FP . MU calculated by T FP (MU-FP) was well correlated with MU by c-T pham (MU-pham) (r=0.94, p=0.001). These results indicate that phantom method is sufficient to substitute for FP method. Though H/M was correlated with MU-FP (p<0.001), the interpatient variation was relatively large. Then the analysis by H/M is insufficient to substitute for the myocardial uptake. It is thought to be enough to use the phantom method on daily routine work, since this method is accurate and easy to quantitate the myocardial uptake of MIBG taking a short time. (author)

  13. Homocysteine levels are associated with the results of {sup 123}I-metaiodobenzylguanidine myocardial scintigraphy in type 2 diabetic patients

    Energy Technology Data Exchange (ETDEWEB)

    Anan, Futoshi; Yonemochi, Hidetoshi; Nakagawa, Mikiko; Saikawa, Tetsunori [Oita University, Department of Cardiovascular Science, Faculty of Medicine, Hasama, Oita (Japan); Masaki, Takayuki; Takahashi, Naohiko; Yoshimatsu, Hironobu [Oita University, Department of Internal Medicine I, Oita (Japan); Eshima, Nobuoki [Oita University, Department of Biostatistics, School of Medicine, Oita (Japan)

    2007-01-15

    Elevated total plasma homocysteine (tHcy) levels and cardiovascular autonomic dysfunction are associated with a high mortality in type 2 diabetic patients. We tested the hypothesis that hyperhomocysteinemia is associated with insulin resistance and cardiovascular autonomic dysfunction in type 2 diabetic patients not receiving insulin treatment. The study group consisted of 17 type 2 diabetic patients with high tHcy levels (>15 mmol/l, age 58{+-}5 years, high tHcy group). The control group consisted of 23 age-matched type 2 diabetic patients with normal tHcy levels ({<=}15 mmol/l, age 58{+-}9 years, normal tHcy group). Cardiovascular autonomic function was assessed by baroreflex sensitivity, heart rate variability, plasma norepinephrine concentrations, and cardiac {sup 123}I-metaiodobenzylguanidine (MIBG) scintigraphy. Early and delayed {sup 123}I-MIBG myocardial uptake values were lower (p<0.005 and p<0.01, respectively) and the percent washout rate of {sup 123}I-MIBG was higher (p<0.001) in the high tHcy group than in the normal tHcy group. The fasting plasma insulin concentrations (p<0.0001) and the homeostasis model assessment (HOMA) index values (p<0.0001) were higher in the high tHcy group than in the normal tHcy group. Multiple regression analysis revealed that the level of tHcy was independently predicted by the HOMA index values and the myocardial uptake of {sup 123}I-MIBG at the delayed phase. Our results demonstrate that high levels of tHcy are associated with depressed cardiovascular autonomic function and insulin resistance in patients with type 2 diabetes mellitus. (orig.)

  14. Labeling of indocyanine green with carrier-free iodine-123

    International Nuclear Information System (INIS)

    Ansari, A.N.; Lambrecht, R.M.; Redvanly, C.S.; Wolf, A.P.

    1976-01-01

    The method is described for labeling indocyanine green (ICG) with carrier-free iodine-123 by condensing xenon-123 on crystals of ICG followed by permitting decay of the 123 Xe a sufficient length of time to produce 123 I-electronically excited ions and atoms which subsequently label ICG. 4 claims, no drawings

  15. Clinical application of iodine 123 with special consideration of radionuclide purity, measuring accuracy and radiation dose

    International Nuclear Information System (INIS)

    Hermann, H.J.; Ammon, J.; Winkel, K. zum; Haubold, U.

    1975-01-01

    Iodine 123 is a nearly 'ideal' radionuclide for thyroid imaging. The production of Iodine 123 requires cyclotrons or accelerators. The production of multicurie amounts of Iodine 123 has been suggested through the use of high-energy accelerators (> 60 MeV). Most of the methods for the production of Iodine 123 using a compact cyclotron result in contamination with f.e. Iodine 124 which reduces the spatial resolution of imaging procedures and increases the radiation dose to the patient. The radiation dose has been calculated for three methods of production. The various contamination with Iodine 124, Iodine 125 and Iodine 126 result in comparable radiation dose of Iodine 131, provided that the time between production and application is more than four half-live-times of Iodine 123. (orig.) [de

  16. Medical necessity for shorter lived radionuclides, specifically pure Iodine-123

    International Nuclear Information System (INIS)

    DeNardo, G.L.; DeNardo, S.J.; Hines, H.H.; Lagunas-Solar, M.C.; Jungerman, J.A.

    1985-01-01

    Iodine-123 has physical and radiochemical characteristics ideal for most tracer procedures performed in patients. Its use is generally preferable to the use of 131 I for diagnosis. The potential for 123 I can be realized only if a radiopharmaceutical of lesser radionuclide contamination is generally and economically available. Iodine-123 produced by direct methods has significant disadvantages relative to quality of procedure and radiation dosimetry. Our experience with 123 I(p,5n) during the past 12 years causes us to vigorously encourage general availability of an 123 I radiopharmaceutical of this quality. Using this product, the authors have prepared radiopharmaceuticals for use in the study of cancer, coagulation, and renal and thyroid diseases

  17. Effects of short-term carvedilol on the cardiac sympathetic activity assessed by {sup 123}I-MIBG scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, Sandra Marina Ribeiro de; Mesquita, Evandro Tinoco; Freire, Fabiano de Lima; Ribeiro, Mario Luiz; Nobrega, Antonio Claudio Lucas da; Mesquita, Claudio Tinoco, E-mail: sandramarina@cardiol.b [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil); Azevedo, Jader Cunha; Barbirato, Gustavo Borges; Coimbra, Alexandro [Hospital Pro-Cardiaco, Rio de Janeiro, RJ (Brazil); Dohmann, Hans Fernando da Rocha [Centro de Ensino e Pesquisa do Pro-Cardiaco (PROCEP), Rio de Janeiro, RJ (Brazil)

    2010-03-15

    Background: autonomic alterations in heart failure are associated with an increase in morbimortality. Several noninvasive methods have been employed to evaluate the sympathetic function, including the Meta-Iodobenzylguanidine ({sup 123}I-MIBG) scintigraphy imaging of the heart. Objective: to evaluate the cardiac sympathetic activity through {sup 123}I-MIBG scintigraphy, before and after three months of carvedilol therapy in patients with heart failure and left ventricular ejection fraction (LVEF) < 45%. Patients and methods: sixteen patients, aged 56.3 +- 12.6 years (11 males), with a mean LVEF of 28% +- 8% and no previous use of beta-blockers were recruited for the study. Images of the heart innervation were acquired with {sup 123}I-MIBG, and the serum levels of catecholamines (epinephrine, dopamine and norepinephrine) were measured; the radioisotope ventriculography (RIV) was performed before and after a three-month therapy with carvedilol. Results: patients' functional class showed improvement: before the treatment, 50% of the patients were FC II and 50% were FC III. After 3 months, 7 patients were FC I (43.8%) and 9 were FC II (56.2%), (rho = 0.0001). The mean LVEF assessed by RIV increased from 29% to 33% (rho = 0.017). There was no significant variation in cardiac adrenergic activity assessed by {sup 123}I-MIBG (early and late resting images and washout rate). No significant variation was observed regarding the measurement of catecholamines. Conclusion: the short-term treatment with carvedilol promoted the clinical and LVEF improvement. However, this was not associated to an improvement in the cardiac adrenergic activity, assessed by {sup 123}I-MIBG scintigraphy, as well as the measurement of circulating catecholamines. (author)

  18. Changes in cardiac adrenergic nervous system in patients submitted to transmyocardial laser revascularisation - assessment with I-123-MIBG SPECT

    International Nuclear Information System (INIS)

    Teresinska, A.; Sliwinski, M.; Konieczna, S.; Szymanska, M.; Hendzel, P.; Juraszynski, Z.; Wojnowski, A.; Debski, A.; Szumilak, B.

    2002-01-01

    Meta-iodobenzylguanidine [MIBG] is an analogue of guanethidine, which, after labelling with iodine-123, has been used for cardiac neuronal imaging in conditions such as coronary artery disease, myocardial infarction, heart failure, cardiac arrhythmia, diabetes mellitus, heart transplantation. The aim of our program using I-123-Mibg is: 1) to study the range of influence of the laser energy (CO 2 -high power laser) during trans myocardial laser revascularisation [Tml] on cardiac adrenergic nervous system, and 2) to assess if disruption of this system can be one of the mechanisms responsible for clinical improvement observed early after Tml. Methods: The patients with high pre-operative probability of having sole TMLR or TMLR combined with only 1 bypass are studied before the operation for neuronal activity with I-123-MIBG SPECT [MIBG-0]. The patients (if they were operated according to the assumption) are studied postoperatively with I-123-MIBG SPECT as early as possible from clinical point of view [MIBG-early] and 6 months after operation [MIBG-6m]. Up to now, in 27 pts the preoperative and early postoperative (7-39 days, av. 13±7 days) tests were performed and in 15 pts - also MIBG-6m was performed. The group characteristics: 21M (78%); age: 43-76y, av. 64±10y; all the patients in III/IV CCS class; 20 pts (74%) after 1-2 MI; 5 pts (19%) after earlier CABG or PTCA. Registration of I-123-MIBG SPECT images was started 4 hrs after injection of the radiopharmaceutical. All SPECT studies were assessed in 17 segments (seg) of the LV. The bypassed seg and the septal seg were excluded from the assessment (as not submitted to the laser). Results: In 22 studies (32%), the evaluation of MIBG uptake was not possible because of very low heart uptake and/or very high extra cardiac uptake. Finally, 18 of the preoperative, 18 of the early postoperative and 11 of the late postoperative studies were submitted to segmental analysis. In MIBG-0, there were 172 uptake defects in

  19. Cardiac {sup 123}I-MIBG scintigraphy in patients with Parkinson`s disease

    Energy Technology Data Exchange (ETDEWEB)

    Orimo, Satoshi [Kanto Central Hospital, Tokyo (Japan)

    1997-08-01

    We discuss the cardiac {sup 123}I-MIBG ({sup 123}I-metaiodobenzylguanidine) scintigraphy in patients with Parkinson`s disease (PD) based on our results, and examine the clinical significance in lowering MIBG storage. Thirty-four patients with PD without diabetes millitus or heart failure, presenting normal cardiac thallium scintigraphy, were examined. They included 13 male and 21 female, aged from 52 to 83 (average age 70.1) and their morbid period was between 0.25 and 19 years (agerage 4.9 years). Ten patients with age-matched disease control were chosen. They contained 5 male and 5 female, aged from 59 to 77 (average age 70.7), suffering from headache, vertigo, cerebral infarction, etc. PD patients group and the age-matched control group were compared with the normal control group. In PD patients, MIBG storage was significantly lowered on the initial and the late images in comparison with the disease and neurological control groups, and the wash-out rate was enhanced. There was negative correlation or the expected tendency of correlation between MIBG storage and the clinical severity. MIBG storage was lowered with longer morbid period. Anti-Parkinson drugs had no apparent effects on MIBG storage. The detection rate of abnormality by cardiac MIBG scintigraphy was clearly higher than that by the sympathetic skin response, and some patients who had no sign on the sympathetic skin response showed the lowering of MIBG storage. The possibility of the failure of the norepinephrine transporter system was indicated as the main cause for the lowering of MIBG storage. (K.H.)

  20. Integrated imaging using MRI and 123I metaiodobenzylguanidine scintigraphy to improve sensitivity and specificity in the diagnosis of pediatric neuroblastoma.

    Science.gov (United States)

    Pfluger, Thomas; Schmied, Christoph; Porn, Ute; Leinsinger, Gerda; Vollmar, Christian; Dresel, Stefan; Schmid, Irene; Hahn, Klaus

    2003-10-01

    The objectives of this study were to compare MRI and iodine-123 ((123)I) metaiodobenzylguanidine (MIBG) scintigraphy in the detection of neuroblastoma lesions in pediatric patients and to assess the additional value of combined imaging. Fifty MRI and 50 (123)I MIBG examinations (mean interval, 6.4 days) were analyzed retrospectively with regard to suspected or proven neuroblastoma lesions (n = 193) in 28 patients. MRI and MIBG scans were reviewed by two independent observers each. Separate and combined analyses of MRI and MIBG scintigraphy were compared with clinical and histologic findings. With regard to the diagnosis of neuroblastoma lesion, MIBG scintigraphy, MRI, and combined analysis showed a sensitivity of 69%, 86%, and 99% and a specificity of 85%, 77%, and 95%, respectively. On MRI, 15 false-positive findings were recorded: posttherapeutic reactive changes (n = 10), benign adrenal tumors (n = 3), and enlarged lymph nodes (n = 2). On MIBG scintigraphy, 10 false-positive findings occurred: ganglioneuromas (n = 2), benign liver tumors (n = 2), and physiologic uptake (n = 6). Thirteen neuroblastoma metastases and two residual masses under treatment with chemotherapy were judged to be false-negative findings on MRI. Two primary or residual neuroblastomas and one orbital metastasis were misinterpreted as Wilms' tumor, reactive changes after surgery, and rhabdomyosarcoma on MRI. Thirty-two bone metastases, six other neuroblastoma metastases, and one adrenal neuroblastoma showed no MIBG uptake. On combined imaging, one false-negative (bone metastasis) and three false-positive (two ganglioneuromas and one pheochromocytoma) findings remained. In the assessment of neuroblastoma lesions in pediatric patients, MRI showed a higher sensitivity and MIBG scintigraphy a higher specificity. However, integrated imaging showed an increase in both sensitivity and specificity.

  1. Usefulness of cardiac 125I-metaiodobenzylguanidine uptake for evaluation of cardiac sympathetic nerve abnormalities in diabetic rats

    International Nuclear Information System (INIS)

    Abe, Nanami; Kashiwagi, Atsunori; Shigeta, Yukio

    1992-01-01

    We investigated cardiac sympathetic nerve abnormalities in streptozocin-induced diabetic rats using 125 I-metaiodobenzylguanidine (MIBG). The radioactivity ratio of cardiac tissue to 1 ml blood (H/B) was used as an index of cardiac MIBG uptake. Cardiac 125 I-MIBG uptake (H/B) in 4-, 8- and 20-wk diabetic rats was 48% lower than that in control rats. Similar results were obtained even when the data were corrected for g wet tissue weight. Although there was no improvement in H/B following 2-wk insulin treatment, the H/B ratio increased significantly, to 85% of control levels, following 4 wk insulin treatment indicating the reversibility of impaired MIBG uptake in diabetic rats. In vivo reserpine treatment resulted in a 50% reduction in the H/B value in control rats. However, the treatment did not significantly suppress uptake in diabetic rats. Cardiac norepinephrine content in both * 4- and ** 8-wk diabetic rats was significantly ( * p ** p 125 I-MIBG in diabetic rats is significantly impaired due to cardiac sympathetic nerve abnormalities. These abnormalities are reversible, however, dependent on the diabetic state. (author)

  2. Renovascular hypertension screening with iodine-123 orthoiodohippurate

    International Nuclear Information System (INIS)

    Oppenheim, B.E.; Appledorn, C.R.; Mock, B.H.; Yune, H.Y.; Grim, C.E.

    1985-01-01

    Screening of 123 hypertensive patients for renovascular disease was carried out through renal studies, performed with iodine-123 ortho-iodohippurate (OIH), consisting of 214 studies performed with high-purity 123 I-OIH and 10 studies performed with 123 I-OIH contaminated with 124 I. Standard dynamic renal images and renogram curves were supplemented by functional renal images generated by computer. For the same radiation dose to the bladder, the number of detected photons with contaminated 123 I-OIH is only about one-third of that for high-purity 123 I-OIH so that for comparable studies one must use at least twice the dose with the former agent as compared with the latter. The study was hampered by erratic delivery of 123 I-OIH, which demonstrated the need for a reliable source

  3. Relationship between late ventricular potentials and myocardial 123I-metaiodobenzylguanidine scintigraphy in patients with dilated cardiomyopathy with mild to moderate heart failure: results of a prospective study of sudden death events

    International Nuclear Information System (INIS)

    Kasama, Shu; Toyama, Takuji; Kaneko, Yoshiaki; Kurabayashi, Masahiko; Iwasaki, Toshiya; Sumino, Hiroyuki; Kumakura, Hisao; Minami, Kazutomo; Ichikawa, Shuichi; Matsumoto, Naoya; Sato, Yuichi

    2012-01-01

    Late ventricular potentials (LPs) are considered to be useful for identifying patients with heart failure at risk of developing ventricular arrhythmias. 123 I-metaiodobenzylguanidine (MIBG) scintigraphy, which is used to evaluate cardiac sympathetic activity, has demonstrated cardiac sympathetic denervation in patients with malignant ventricular tachyarrhythmias. This study was undertaken to clarify the relationship between LPs and 123 I-MIBG scintigraphy findings in patients with dilated cardiomyopathy (DCM). A total of 56 patients with DCM were divided into an LP-positive group (n = 24) and an LP-negative group (n = 32). During the compensated period, the delayed heart/mediastinum count (H/M) ratio, delayed total defect score (TDS), and washout rate (WR) were determined from 123 I-MIBG images and plasma brain natriuretic peptide (BNP) concentrations were measured. Left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV), and left ventricular ejection fraction (LVEF) were simultaneously determined by echocardiography. LVEDV, LVESV, LVEF and plasma BNP concentrations were similar in the two groups. However, TDS was significantly higher (35 ± 8 vs. 28 ± 6, p 123 I-MIBG scintigraphic parameters were worse in LP-positive DCM patients than in LP-negative DCM patients. Furthermore, in LP-positive DCM patients with a high WR, the incidence of sudden death events was higher than that in other subgroups of DCM patients. (orig.)

  4. Metaiodobenzylguanidine [131I] scintigraphy detects impaired myocardial sympathetic neuronal transport function of canine mechanical-overload heart failure

    International Nuclear Information System (INIS)

    Rabinovitch, M.A.; Rose, C.P.; Rouleau, J.L.

    1987-01-01

    In heart failure secondary to chronic mechanical overload, cardiac sympathetic neurons demonstrate depressed catecholamine synthetic and transport function. To assess the potential of sympathetic neuronal imaging for detection of depressed transport function, serial scintigrams were acquired after the intravenous administration of metaiodobenzylguanidine [ 131 I] to 13 normal dogs, 3 autotransplanted (denervated) dogs, 5 dogs with left ventricular failure, and 5 dogs with compensated left ventricular hypertrophy due to a surgical arteriovenous shunt. Nine dogs were killed at 14 hours postinjection for determination of metaiodobenzylguanidine [ 131 I] and endogenous norepinephrine content in left atrium, left ventricle, liver, and spleen. By 4 hours postinjection, autotransplanted dogs had a 39% reduction in mean left ventricular tracer accumulation, reflecting an absent intraneuronal tracer pool. Failure dogs demonstrated an accelerated early mean left ventricular tracer efflux rate (26.0%/hour versus 13.7%/hour in normals), reflecting a disproportionately increased extraneuronal tracer pool. They also showed reduced late left ventricular and left atrial concentrations of tracer, consistent with a reduced intraneuronal tracer pool. By contrast, compensated hypertrophy dogs demonstrated a normal early mean left ventricular tracer efflux rate (16.4%/hour) and essentially normal late left ventricular and left atrial concentrations of tracer. Metaiodobenzylguanidine [ 131 I] scintigraphic findings reflect the integrity of the cardiac sympathetic neuronal transport system in canine mechanical-overload heart failure. Metaiodobenzylguanidine [ 123 I] scintigraphy should be explored as a means of early detection of mechanical-overload heart failure in patients

  5. Cardiac Sympathetic Hyperactivity after Chemotherapy: Early Sign of Cardiotoxicity?

    Energy Technology Data Exchange (ETDEWEB)

    Guimarães, Sarita Lígia Pessoa de Melo Machado [Pós-Graduação em Ciências da Saúde da Universidade Federal de Pernambuco (PGCS-UFPE), Recife, PE (Brazil); Hospital Agamenon Magalhães (HAM), Recife, PE (Brazil); Brandão, Simone Cristina Soares, E-mail: simonecordis@yahoo.com.br [Pós-Graduação em Ciências da Saúde da Universidade Federal de Pernambuco (PGCS-UFPE), Recife, PE (Brazil); Andrade, Luciana Raposo [Hospital Santa Joana, Recife, PE (Brazil); Maia, Rafael José Coelho [Pós-Graduação em Ciências da Saúde da Universidade Federal de Pernambuco (PGCS-UFPE), Recife, PE (Brazil); Hospital Agamenon Magalhães (HAM), Recife, PE (Brazil); Markman Filho, Brivaldo [Pós-Graduação em Ciências da Saúde da Universidade Federal de Pernambuco (PGCS-UFPE), Recife, PE (Brazil)

    2015-09-15

    Chemotherapy with anthracyclines and trastuzumab can cause cardiotoxicity. Alteration of cardiac adrenergic function assessed by metaiodobenzylguanidine labeled with iodine-123 ({sup 123}I-mIBG) seems to precede the drop in left ventricular ejection fraction. To evaluate and to compare the presence of cardiovascular abnormalities among patients with breast cancer undergoing chemotherapy with anthracyclines and trastuzumab, and only with anthracycline. Patients with breast cancer were analyzed clinical, laboratory, electrocardiographic and echocardiographic and cardiac sympathetic activity. In scintigraphic images, the ratio of {sup 123}I-mIBG uptake between the heart and mediastinum, and the washout rate were calculated. The variables were compared between patients who received anthracyclines and trastuzumab (Group 1) and only anthracyclines (Group 2). Twenty patients, with mean age 57 ± 14 years, were studied. The mean left ventricular ejection fraction by echocardiography was 67.8 ± 4.0%. Mean washout rate was 28.39 ± 9.23% and the ratio of {sup 123}I-mIBG uptake between the heart and mediastinum was 2.07 ± 0.28. Of the patients, 82% showed an increased in washout rate, and the ratio of {sup 123}I-mIBG uptake between the heart and mediastinum decreased in 25%. Concerning the groups, the mean washout rate of Group 1 was 32.68 ± 9.30% and of Group 2 was 24.56 ± 7.72% (p = 0,06). The ratio of {sup 123}I-mIBG uptake between the heart and mediastinum was normal in all patients in Group 2, however, the Group 1, showed 50% the ratio of {sup 123}I-mIBG uptake between the heart and mediastinum ≤ 1.8 (p = 0.02). In women with breast cancer undergoing chemotherapy, assessment of cardiac sympathetic activity with {sup 123}I-mIBG appears to be an early marker of cardiotoxicity. The combination of chemotherapy showed higher risk of cardiac adrenergic hyperactivity.

  6. Abdominal visceral fat accumulation is associated with the results of {sup 123}I-metaiodobenzylguanidine myocardial scintigraphy in type 2 diabetic patients

    Energy Technology Data Exchange (ETDEWEB)

    Anan, Futoshi [Oita Red Cross Hospital, Department of Cardiology, Oita (Japan); Oita University, Department of Internal Medicine I, Oita (Japan); Masaki, Takayuki; Takahashi, Naohiko; Yoshimatsu, Hironobu [Oita University, Department of Internal Medicine I, Oita (Japan); Yonemochi, Hidetoshi; Nakagawa, Mikiko; Saikawa, Tetsunori [Oita University, Department of Cardiovascular Science, Oita (Japan); Eshima, Nobuoki [Oita University, Department of Biostatistics, School of Medicine, Oita (Japan)

    2007-08-15

    We tested the hypothesis that increased abdominal visceral accumulation (VFA) is associated with insulin resistance and cardiovascular autonomic dysfunction in type 2 diabetic patients not receiving insulin treatment. The fat distribution was evaluated by measuring the VFA by abdominal computed tomography at the umbilical level. The study group consisted of 24 type 2 diabetic patients with high VFA ({>=}100 cm{sup 2}, age 60 {+-} 8 years, high VFA group). The control group consisted of 19 age-matched type 2 diabetic patients with normal VFA (<100 cm{sup 2}, age 60 {+-} 7 years, normal VFA group). Cardiovascular autonomic function was assessed by baroreflex sensitivity, heart rate variability, plasma norepinephrine concentrations, and cardiac {sup 123}I-metaiodobenzylguanidine (MIBG) scintigraphy. Early and delayed {sup 123}I-MIBG myocardial uptake values were lower (p < 0.005 and p < 0.0001, respectively) and the percent washout rate of {sup 123}I-MIBG was higher (p < 0.0005) in the high VFA group than in the normal VFA group. The fasting plasma insulin concentrations (p < 0.005) and the homeostasis model assessment (HOMA) index values (p < 0.0005) were higher in the high VFA group than in normal VFA group. Multiple regression analysis revealed that the level of VFA was independently predicted by the HOMA index values and the myocardial uptake of {sup 123}I-MIBG during the delayed phase. Our results demonstrate that the level of VFA is associated with depressed cardiovascular autonomic function and insulin resistance in patients with type 2 diabetes mellitus. (orig.)

  7. Metastatic phaeochromocytoma with a long-term response after iodine-131 metaiodobenzylguanidine therapy

    International Nuclear Information System (INIS)

    Pujol, P.; Bringer, J.; Faurous, P.; Jaffiol, C.

    1995-01-01

    Iodine-131 metaiodobenzylguanidine ([ 131 I] MIBG), a radiopharmaceutical agent, is used for treating malignant phaeochromocytoma. [ 131 I]MIBG therapy results in a hormone response rate of approximately 50%, but generally it yields only a partial or no tumour response. We present a case of a 46-year-old woman with a familial history of von Hippel-Lindau disease, who was treated with [ 131 I]MIBG for a metastatic phaeochromocytoma involving the lungs, liver and bones. The patient received a cumulative dose of 33.3 GBq (900 mCi) and a complete hormone response was observed, as evaluated on the basis of catecholamine and metanephrine levels. Conventional radiography, computerized tomography and [ 131 I]MIBG scintigraphy indicated that a near-complete tumour regression was achieved, with no evidence of relapse during a 4-year follow-up period. This case thus demonstrates that treatment with [ 131 I]MIBG may lead to a dramatic tumour response in malignant phaeochromocytoma presenting both soft tissue and bone metastases. (orig.)

  8. 6-[F-18]Fluoro-L-Dihydroxyphenylalanine Positron Emission Tomography Is Superior to Conventional Imaging with I-123-Metaiodobenzylguanidine Scintigraphy, Computer Tomography, and Magnetic Resonance Imaging in Localizing Tumors Causing Catecholamine Excess

    NARCIS (Netherlands)

    Fiebrich, Helle-Brit; Brouwers, Adrienne H.; Kerstens, Michiel N.; Pijl, Milan E. J.; Kema, Ido P.; de Jong, Johan R.; Jager, Pieter L.; Elsinga, Philip H.; Dierckx, Rudi A. J. O.; van der Wal, Jacqueline E.; Sluiter, Wim J.; de Vries, Elisabeth G. E.; Links, Thera P.

    2009-01-01

    Context: Catecholamine excess is rare, but symptoms may be life threatening. Objective: The objective of the study was to investigate the sensitivity of 6-[F-18]fluoro-L-dihydroxyphenylalanine positron emission tomography (F-18-DOPAPET), compared with I-123-metaiodobenzylguanidine (I-123-MIBG)

  9. Iodine-clearance-equivalent (123I) for delineation of thyroid dysfunctions

    International Nuclear Information System (INIS)

    Licht, E.

    1981-01-01

    In 138 patients whose thyroid function was proved by R T 3 -uptake, T 4 -RIA, T 3 -RIA, FT 4 , FT 3 the iodine uptake of the thyroid 2 and 4 hours after application of 200 μCi 123 iodine p.o. or i.v., respectively after application of 34 μCi 131 iodine p.o. was determined. 2 hours after application of radioiodine plasma acitivity was measured. The ratio between increase/hour of uptake and plasma level of activity after 2 hours was taken as clearance equivalent, which does not measure the correct value of iodine clearance but is sufficiently related to it. The type of radioiodine and the method of application had no influence on the results. There was significant difference between euthyroid adenoma, euthyroid adenoma and hyperthyroid adenoma. The advantage of the technique is the practicability, the short occupancy of the uptake system and the reduction of radiation dosage by consequent use of 123 iodine. The second uptake measurement coincides with thyroid imaging, which results in time saving for the patient. (orig.) [de

  10. The impact of acquisition time of planar cardiac 123I-MIBG imaging on the late heart to mediastinum ratio

    International Nuclear Information System (INIS)

    Dimitriu-Leen, Aukelien C.; Veltman, Caroline E.; Bax, Jeroen J.; Scholte, Arthur J.H.A.; Gimelli, Alessia; Al Younis, Imad; Verberne, Hein J.; Wolterbeek, Ron; Zandbergen-Harlaar, Silvia

    2016-01-01

    The aim of this study was to investigate whether performing the late cardiac 123 I-metaiodobenzylguanidine (MIBG) scan earlier than 4 h post-injection (p.i.) has relevant impact on the late heart to mediastinum ratio (H/M ratio) in patients with heart failure (HF). Forty-nine patients with HF (median left ventricular ejection fraction of 31 %, 51 % ischaemic HF) referred for cardiac 123 I-MIBG scintigraphy were scanned at 15 min (early) p.i. and at 1, 2, 3 and 4 h (late) p.i. of 123 I-MIBG. Late H/M ratios were calculated and evaluated using a linear mixed model with the mean late H/M ratio at 4 h p.i. as a reference. A difference in late H/M ratios of more than 0.10 between the different acquisition times in comparison with the late H/M ratio at 4 h p.i. was considered as clinically relevant. Statistically significant mean differences were observed between the late H/M ratios at 1, 2 and 3 h p.i. compared with the late H/M ratio at 4 h p.i. (0.09, 0.05 and 0.02, respectively). However, the mean differences did not exceed the cut-off value of 0.10. On an individual patient level, compared to the late H/M ratio at 4 h p.i., the late H/M ratios at 1, 2 and 3 h p.i. differed more than 0.10 in 24 (50 %), 9 (19 %) and 2 (4 %) patients, respectively. Variation in acquisition time of 123 I-MIBG between 2 and 4 h p.i. does not lead to a clinically significant change in the late H/M ratio. An earlier acquisition time seems to be justified and may warrant a more time-efficient cardiac 123 I-MIBG imaging protocol. (orig.)

  11. Dosimetry of iodine-123 for newborn and infant

    International Nuclear Information System (INIS)

    Guilhem, M.T.; Therain, F.

    1987-01-01

    Iodine-123 ( 123 I) is a radionuclide of choice of neonatal hypothyroidism diagnosis. It is important to know infant main organs adsorbed doses during a thyroid scan with 123 I. Absorbed doses are already available for adults: for infants, they must be transformed taking account of organs sizes and inter-organs distances. Calculations are done for commercially available 123 I(p,2n) and 123 I(p,5n). Important contamination of 124 I in 123 I(p,2n) increases considerably the absorbed-dose during thyroid scan of a newborn (the ratio 124 I/ 123 I doubles every 15h). For routinely used activities, thyroid absorbed dose, 24 h after end of production, is fifteen times higher with 123 I(p,5n) than with 99m Tc: for one month old child; total body absorbed dose is of the same order of magnitude [fr

  12. Is it time for cardiac innervation imaging?

    Energy Technology Data Exchange (ETDEWEB)

    Knuuti, J. [Turku Univ., Turku (Finland) Turku PET Center; Sipola, P. [Kuopio Univ., Kuopio (Finland)

    2005-03-01

    The autonomic nervous system plays an important role in the regulation of cardiac function and the regional distribution of cardiac nerve terminals can be visualized using scintigraphic techniques. The most commonly used tracer is iodine-123-metaiodobenzylguanidine (MIBG) but C-11-hydroxyephedrine has also been used with PET. When imaging with MIBG, the ratio of heart-to-mediastinal counts is used as an index of tracer uptake, and regional distribution is also assessed from tomographic images. The rate of clearance of the tracer can also be measured and indicates the function of the adrenergic system. Innervation imaging has been applied in patients with susceptibility to arrythmias, coronary artery disease, hypertrophic and dilated cardiomyopathy and anthracycline induced cardiotoxicity. Abnormal adrenergic innervation or function appear to exist in many pathophysiological conditions indicating that sympathetic neurons are very susceptible to damage. Abnormal findings in innervation imaging also appear to have significant prognostic value especially in patients with cardiomyopathy. Recently, it has also been shown that innervation imaging can monitor drug-induced changes in cardiac adrenergic activity. Although innervation imaging holds great promise for clinical use, the method has not received wider clinical acceptance. Larger randomized studies are required to confirm the value of innervation imaging in various specific indications.

  13. I-Metaiodobenzylguanidine Myocardial Scintigraphy in Lewy Body-Related Disorders: A Literature Review

    Directory of Open Access Journals (Sweden)

    Eun Joo Chung

    2015-05-01

    Full Text Available Lewy body-related disorders are characterized by the presence of Lewy bodies and Lewy neurites, which have abnormal aggregations of α-synuclein in the nigral and extranigral areas, including in the heart. 123I-metaiodobenzylguanidine (MIBG scintigraphy is a well-known tool to evaluate cardiac sympathetic denervation in the Lewy body-related disorders. MIBG scintigraphy showed low uptake of MIBG in the Lewy body-related disorders, including Parkinson’s disease, dementia with Lewy bodies, pure autonomic failure and rapid eye movement sleep behavior disorder. This review summarizes previous results on the diagnostic applications of MIBG scintigraphy in Lewy body-related disorders.

  14. Evaluation of sympathetic activity by 123I-metaiodobenzylguanidine myocardial scintigraphy in dilated cardiomyopathy patients with sleep breathing disorder

    International Nuclear Information System (INIS)

    Nanjo, Shuji; Fujimoto, Shinichiro; Yamashiro, Yoshihiro

    2009-01-01

    Because increased sympathetic nervous activity (SNA) in patients with dilated cardiomyopathy (DCM) associated with sleep breathing disorder (SBD) is known to deteriorate the prognosis of cardiac failure, 123 I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy was used as the investigative tool in the present study. The study group comprised 53 patients (47 men, 6 women; mean age 56±3 years) with chronic stable DCM. Patients were divided into SBD(+) or SBD(-) group according to 24-h pulse oximetry results. SBD(+) was defined when the 3% oxygen desaturation index was more than 15/h during sleep. In total, 32 patients were SBD(-) and 21 were SBD(+). In both groups, pulse oximetry were performed during sleep and awakening pulse rate, and measurement of the blood levels of catecholamines and B-type natriuretic peptide was performed. MIBG myocardial scintigraphy and echocardiography were performed at the same time. No significant difference was found between the 2 groups in catecholamine levels or left ventricular ejection fraction. However, MIBG had a significantly increased washout rate and a significantly decreased delayed heart to mediastinum ratio in the SBD(+) group compared with the SBD(-) group. SNA is increased in DCM patients when associated with SBD. MIBG myocardial scintigraphy may be a sensitive method of detecting increased SNA. (author)

  15. Iodine-123 and bromine-75 production and development program at Juelich

    International Nuclear Information System (INIS)

    Stoecklin, G.

    1985-01-01

    The iodine-123 and bromine-75 production and development program at the Nuclear Research Center in Juelich as of 1982 is described, and examples of recent 123 I- and 75 Br-analogue tracers that have been developed to the level of clinical trial are given. Iodine-123 is produced via the 127 I(d,6n) 123 Xe → 123 I process and by the 124 Te(p,2n) 123 I and 122 Te(d,n) 123 I reactions. These production methods are critically reviewed. Bromine-75-labeled benzodiazenes have been prepared for in vivo mapping of benzodiazepine receptor sites. The 7-( 75 Br)-5-(2-fluorophenyl)-1-methyl-1,3-dihydro-2H-1,4-benzodiazepine-2-one (BFB) was prepared with a specific activity of > 10 4 Ci/mmole. Finally, preparation and applications of the halogenated amino acid L-3-( 123 I)-iodo-α-methyltyrosine (IMT) and the analogous 75 Br compound (BMT) are reported. Both IMT and BMT have been successfully applied for pancreas imaging and tomography, and IMT has been used for imaging both melanotic and amelanotic malignant melanoma of the eye

  16. Quantitative SPECT reconstruction of iodine-123 data

    International Nuclear Information System (INIS)

    Gilland, D.R.; Jaszczak, R.J.; Greer, K.L.; Coleman, R.E.

    1991-01-01

    Many clinical and research studies in nuclear medicine require quantitation of iodine-123 ( 123 I) distribution for the determination of kinetics or localization. The objective of this study was to implement several reconstruction methods designed for single-photon emission computed tomography (SPECT) using 123 I and to evaluate their performance in terms of quantitative accuracy, image artifacts, and noise. The methods consisted of four attenuation and scatter compensation schemes incorporated into both the filtered backprojection/Chang (FBP) and maximum likelihood-expectation maximization (ML-EM) reconstruction algorithms. The methods were evaluated on data acquired of a phantom containing a hot sphere of 123 I activity in a lower level background 123 I distribution and nonuniform density media. For both reconstruction algorithms, nonuniform attenuation compensation combined with either scatter subtraction or Metz filtering produced images that were quantitatively accurate to within 15% of the true value. The ML-EM algorithm demonstrated quantitative accuracy comparable to FBP and smaller relative noise magnitude for all compensation schemes

  17. Imaging the primate adrenal medulla with [123I] and [131I] metaiodobenzylguanidine: concise communication

    International Nuclear Information System (INIS)

    Wieland, D.M.; Brown, L.E.; Tobes, M.C.; Rogers, W.L.; Marsh, D.D.; Mangner, T.J.; Swanson, D.P.; Beierwaltes, W.H.

    1981-01-01

    An evaluation of radioiodinated meta-iodobenzylguanidine (m-IBG) as an adrenomedullary imaging agent is reported in 15 rhesus monkeys. Scintiscans of the monkey adrenal medulla have been obtained with [ 123 I]- and [m- 131 ]IBG at 2 to 6 days after injection. The imaging superiority of m-IBG over its positional isomer, para-iodobenzylguanidine (p-IBG), is documented in both dogs and monkeys. Administration of reserpine, a depletor of catecholamine stores, markedly lowers the [m- 131 I]-IBG content of the dog adrenal medulla, but the adrenergic blocking agents phenoxybenzamine and propanolol have no effect. Subcellular fractionation of the dog's adrenal medullae reveals that m-IBG is sequestered mainly in the chromaffin storage granules. The results of this study suggest that radioiodinated m-IBG, previously reported to image the primate myocardium, also merits evaluation as a clinical radiopharmaceutical for the adrenal medulla

  18. Clinical evaluation of 123I-metaiodobenzylguanidine myocardial scintigram in patients with vascular heart disease

    International Nuclear Information System (INIS)

    Terada, Kouji; Sugihara, Hiroki; Shiga, Koji

    1995-01-01

    Myocardial sympathetic nerve function can be evaluated by 123 I-metaiodobenzylguanidine (MIBG) scintigraphy. Congestive heart failure is closely related to myocardial sympathetic nerve function. This study evaluated the severity of congestive heart failure in 30 patients with valvular heart disease [aortic regurgitation (AR): n=20, mean age=70±13 years; mitral regurgitation (MR): n=10, mean age=61±18 years], who had chronic heart failure by MIBG myocardial scintigraphy. Single photon emission computed tomography (SPECT) and anterior planar myocardial images were obtained 15 minutes (initial images) and 4 hours (delayed images) after injection of MIBG (111 MBq). Defect score was determined by the delayed SPECT images visually as a semi-quantitative index. Myocardial MIBG uptake was quantified by the heart to upper mediastinum uptake ratio on the delayed anterior planar images (H/M) and mean cardiac MIBG washout rate during 4 hours was calculated from the bull's eye display data (clearance). These indices were compared with the NYHA class and echocardiographic findings of the patients. MIBG regional defect in the delayed image was most frequently seen in the inferoposterior wall, and defect score and clearance were significantly higher and the H/M ratio was significantly lower in NYHA class III patients than in class II patients. In patients with AR, clearance significantly correlated with left ventricular end-systolic dimension. In patients with MR, both the H/M ratio and clearance significantly correlated with left atrial dimension. Defect score, H/M, and clearance were closely related to the severity of AR and MR. These results indicate that MIBG scan can be used to assess the severity of valvular heart disease. (author)

  19. Technetium-99m labeled 1-(4-fluorobenzyl)-4-(2-mercapto-2-methyl-4-azapentyl)-4- (2-mercapto-2-methylp ropylamino)-piperidine and iodine-123 metaiodobenzylguanidine for studying cardiac adrenergic function: a comparison of the uptake characteristics in vascular smooth muscle cells and neonatal cardiac myocytes, and an investigation in rats

    International Nuclear Information System (INIS)

    Samnick, Samuel; Scheuer, Claudia; Muenks, Sven; El-Gibaly, Amr M.; Menger, Michael D.; Kirsch, Carl-Martin

    2004-01-01

    In developing technetium-99m-based radioligands for in vivo studies of cardiac adrenergic neurons, we compared the uptake characteristics of the 99m Tc-labeled 1-(4-fluorobenzyl)-4-(2-mercapto-2-methyl-4-azapentyl)-4- (2-mercapto-2-methylpropylamino)-piperidine ( 99m Tc-FBPBAT) with those of the clinically established meta-[ 123 I]iodobenzylguanidine ( 123 I-MIBG) in rat vascular smooth muscle cells and neonatal cardiac myocytes. Furthermore, the cardiac and extracardiac uptake of both radiopharmaceuticals was assessed in intact rats and in rats pretreated with various α- and β-adrenoceptor drugs, and adrenergic reuptake blocking agents. The uptake of 99m Tc-FBPBAT and 123 I-MIBG into vascular smooth muscle cells and neonatal cardiac myocytes was rapid; more than 85% of the radioactivity accumulation into the cells occurring within the first 3 minutes. Radioactivity uptake after a 60-minute incubation at 37 degree sign C (pH 7.4) varied from 15% to 65% of the total loaded activity per million cells. In all cases, 99m Tc-FBPBAT showed the higher uptake, relative to 123 I-MIBG, at any given cell concentration. The cellular uptake of 99m Tc-FBPBAT was lower at 4 degree sign C and 20 degree sign C than at 37 degree sign C. In contrast, the 123 I-MIBG uptake was only slightly temperature dependent. Inhibition experiments confirmed that the cellular uptake of 123 I-MIBG is mediated by the uptake-I carrier, whereas α 1 - and β 1 -adrenoceptors were predominantly involved in the uptake of 99m Tc-FBPBAT into the cardiovascular tissues. Biodistribution studies in rats showed that 99m Tc-FBPBAT accumulated in myocardium after intravenous injection. Radioactivity in rat heart amounted to 2.32% and 1.91% of the injected dose per gram at 15 and 60 minutes postinjection, compared with 3.10% and 2.21% injected dose per gram of tissue (%ID/g) in the experiment with 123 I-MIBG, respectively. Prazosin, urapidil, and metoprolol were as effective as treatment with other adrenergic

  20. Technetium-99m labeled 1-(4-fluorobenzyl)-4-(2-mercapto-2-methyl-4-azapentyl)-4- (2-mercapto-2-methylp ropylamino)-piperidine and iodine-123 metaiodobenzylguanidine for studying cardiac adrenergic function: a comparison of the uptake characteristics in vascular smooth muscle cells and neonatal cardiac myocytes, and an investigation in rats

    Energy Technology Data Exchange (ETDEWEB)

    Samnick, Samuel E-mail: rassam@uniklinik-saarland.de; Scheuer, Claudia; Muenks, Sven; El-Gibaly, Amr M.; Menger, Michael D.; Kirsch, Carl-Martin

    2004-05-01

    In developing technetium-99m-based radioligands for in vivo studies of cardiac adrenergic neurons, we compared the uptake characteristics of the {sup 99m}Tc-labeled 1-(4-fluorobenzyl)-4-(2-mercapto-2-methyl-4-azapentyl)-4- (2-mercapto-2-methylpropylamino)-piperidine ({sup 99m}Tc-FBPBAT) with those of the clinically established meta-[{sup 123}I]iodobenzylguanidine ({sup 123}I-MIBG) in rat vascular smooth muscle cells and neonatal cardiac myocytes. Furthermore, the cardiac and extracardiac uptake of both radiopharmaceuticals was assessed in intact rats and in rats pretreated with various {alpha}- and {beta}-adrenoceptor drugs, and adrenergic reuptake blocking agents. The uptake of {sup 99m}Tc-FBPBAT and {sup 123}I-MIBG into vascular smooth muscle cells and neonatal cardiac myocytes was rapid; more than 85% of the radioactivity accumulation into the cells occurring within the first 3 minutes. Radioactivity uptake after a 60-minute incubation at 37 degree sign C (pH 7.4) varied from 15% to 65% of the total loaded activity per million cells. In all cases, {sup 99m}Tc-FBPBAT showed the higher uptake, relative to {sup 123}I-MIBG, at any given cell concentration. The cellular uptake of {sup 99m}Tc-FBPBAT was lower at 4 degree sign C and 20 degree sign C than at 37 degree sign C. In contrast, the {sup 123}I-MIBG uptake was only slightly temperature dependent. Inhibition experiments confirmed that the cellular uptake of {sup 123}I-MIBG is mediated by the uptake-I carrier, whereas {alpha}{sub 1}- and {beta}{sub 1}-adrenoceptors were predominantly involved in the uptake of {sup 99m}Tc-FBPBAT into the cardiovascular tissues. Biodistribution studies in rats showed that {sup 99m}Tc-FBPBAT accumulated in myocardium after intravenous injection. Radioactivity in rat heart amounted to 2.32% and 1.91% of the injected dose per gram at 15 and 60 minutes postinjection, compared with 3.10% and 2.21% injected dose per gram of tissue (%ID/g) in the experiment with {sup 123}I

  1. Iodine-123 in Western Europe

    International Nuclear Information System (INIS)

    Qaim, S.M.; Stoecklin, G.; Weinreich, R.

    1976-08-01

    The major object of this panel was to obtain information on the state of art of Iodine-123 production in Western Europe. Technical, medical and organizational problems were discussed extensively during the one-day meeting and a stimulating exchange of information between the various 123 I-producers and users has been initiated. Some specific examples of medical application were also included in order to get a feeling of the degree of acceptance by the medical community and the demand for this isotope. The meeting clearly demonstrated the great demand for this isotope but it also showed that the present rate of production is well below the demand. In order to fill this gap, not only further technical development is needed but also the organizational question of distribution has to be solved, perhaps within a network of collaborating cyclotrons, a task which is considerably more difficult in Western Europe than in the USA. (orig./HP) [de

  2. Diagnosis and treatment of neuroblastoma using metaiodobenzylguanidine

    International Nuclear Information System (INIS)

    Edeling, C.J.; Frederiksen, P.B.; Kamper, J.; Jeppesen, P.

    1987-01-01

    Neuroblastoma is a lethal and not uncommon tumor in childhood. Early detection and display of the spread of the tumor is highly desirable for proper treatment. Nine children suspected of having neuroblastomas were examined by I-131 metaiodobenzylguanidine (I-131 MIBG) imaging. In two recent studies I-123 metaiodobenzylguanidine (I-123 MIBG) was used. A primary adrenal neuroblastoma was correctly identified in three cases. In two patients additional tumor sites were found. In one patient, who was in complete remission, no pathologic accumulation of I-131 MIBG was found. I-131 MIBG images were also normal in four patients with other types of neoplastic diseases. A boy with multiple metastases was treated with 100 mCi of I-131 MIBG. He developed transient gastrointestinal illness and there was no regression of the tumor deposits. In one girl with a large adrenal neuroblastoma high uptake of I-131 MIBG was observed. She received two therapy doses of I-131 MIBG (35 mCi and 75 mCi) with curative intention giving a total absorbed dose in the tumor of approximately 76 Gy. In spite of high retention of radioactivity in the tumor, regression did not occur, but her general condition was improved. In the present study, images of superior quality were obtained with I-123 MIBG imaging. It is concluded that imaging using I-131 MIBG or I-123 MIBG should be used in both the initial evaluation and the follow-up of children with neuroblastoma

  3. Clinical evaluation of {sup 123}I-metaiodobenzylguanidine myocardial scintigram in patients with vascular heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Terada, Kouji; Sugihara, Hiroki; Shiga, Koji [Kyoto Prefectural Univ. of Medicine (Japan)] [and others

    1995-05-01

    Myocardial sympathetic nerve function can be evaluated by {sup 123}I-metaiodobenzylguanidine (MIBG) scintigraphy. Congestive heart failure is closely related to myocardial sympathetic nerve function. This study evaluated the severity of congestive heart failure in 30 patients with valvular heart disease [aortic regurgitation (AR): n=20, mean age=70{+-}13 years; mitral regurgitation (MR): n=10, mean age=61{+-}18 years], who had chronic heart failure by MIBG myocardial scintigraphy. Single photon emission computed tomography (SPECT) and anterior planar myocardial images were obtained 15 minutes (initial images) and 4 hours (delayed images) after injection of MIBG (111 MBq). Defect score was determined by the delayed SPECT images visually as a semi-quantitative index. Myocardial MIBG uptake was quantified by the heart to upper mediastinum uptake ratio on the delayed anterior planar images (H/M) and mean cardiac MIBG washout rate during 4 hours was calculated from the bull`s eye display data (clearance). These indices were compared with the NYHA class and echocardiographic findings of the patients. MIBG regional defect in the delayed image was most frequently seen in the inferoposterior wall, and defect score and clearance were significantly higher and the H/M ratio was significantly lower in NYHA class III patients than in class II patients. In patients with AR, clearance significantly correlated with left ventricular end-systolic dimension. In patients with MR, both the H/M ratio and clearance significantly correlated with left atrial dimension. Defect score, H/M, and clearance were closely related to the severity of AR and MR. These results indicate that MIBG scan can be used to assess the severity of valvular heart disease. (author).

  4. Iodine-123 iodobenzofuran (I-123 IBF) SPECT in patients with parkinsonism

    Energy Technology Data Exchange (ETDEWEB)

    Nakabeppu, Yoshiaki; Nakajo, Masayuki; Mitsuda, Mitsuru; Tsuchimochi, Shinsaku; Tani, Atsushi; Osame, Mitsuhiro [Kagoshima Univ. (Japan). Faculty of Medicine

    1999-12-01

    Iodine-123 benzofuran (I-123 IBF) is a dopaminergic antagonist which is suitable for SPECT imaging of D2 receptors. The purpose of this study is to evaluate the potential usefulness of semi-quantitative parameters obtained from brain SPECT data of I-123 IBF for differential diagnosis in patients with parkinsonism (PN). Subjects were 10 patients with PN: 2 patients with striato-nigral degeneration (SND), 5 patients with Parkinson's disease (PD), 2 patients with progressive supranuclear palsy (PSP) and one patient with olivo-ponto-cerebellar atrophy (OPCA). The data were acquired with a triple-head gamma camera at 2 hours after intravenous injection of 167 MBq of I-123 IBF. Transverse images were reconstructed by means of filtered backprojection, and attenuation correction was performed by Chang's method ({mu}=0.08). The basal ganglia-to-frontal cortex ratio (GFR) and the basal ganglia-to-occipital cortex ratio (GOR) on slices of 5 different thicknesses were calculated. The GFR and GOR were lower in the SND group than in the other disease groups in all slices with different thicknesses (7.2 mm, 14.4 mm, 21.6 mm, 28.8 mm and 43.2 mm). The semiquantitative parameters (GFR and GOR) obtained from brain SPECT data at 2 hours after intravenous injection of I-123 IBF may be useful for differential diagnosis in patients with PN. (author)

  5. Iodine-123 iodobenzofuran (I-123 IBF) SPECT in patients with parkinsonism

    International Nuclear Information System (INIS)

    Nakabeppu, Yoshiaki; Nakajo, Masayuki; Mitsuda, Mitsuru; Tsuchimochi, Shinsaku; Tani, Atsushi; Osame, Mitsuhiro

    1999-01-01

    Iodine-123 benzofuran (I-123 IBF) is a dopaminergic antagonist which is suitable for SPECT imaging of D2 receptors. The purpose of this study is to evaluate the potential usefulness of semi-quantitative parameters obtained from brain SPECT data of I-123 IBF for differential diagnosis in patients with parkinsonism (PN). Subjects were 10 patients with PN: 2 patients with striato-nigral degeneration (SND), 5 patients with Parkinson's disease (PD), 2 patients with progressive supranuclear palsy (PSP) and one patient with olivo-ponto-cerebellar atrophy (OPCA). The data were acquired with a triple-head gamma camera at 2 hours after intravenous injection of 167 MBq of I-123 IBF. Transverse images were reconstructed by means of filtered backprojection, and attenuation correction was performed by Chang's method (μ=0.08). The basal ganglia-to-frontal cortex ratio (GFR) and the basal ganglia-to-occipital cortex ratio (GOR) on slices of 5 different thicknesses were calculated. The GFR and GOR were lower in the SND group than in the other disease groups in all slices with different thicknesses (7.2 mm, 14.4 mm, 21.6 mm, 28.8 mm and 43.2 mm). The semiquantitative parameters (GFR and GOR) obtained from brain SPECT data at 2 hours after intravenous injection of I-123 IBF may be useful for differential diagnosis in patients with PN. (author)

  6. Automatic production of Iodine-123 with PLC 135/U

    International Nuclear Information System (INIS)

    Moghaddam-Banaem, L.; Afarideh, H.

    2004-01-01

    In this project, the automatic system for production of Iodine-123 with PLC/135μ Siemens, which is designed and installed for the first time in Iran, is discussed. The PLC (Programmable Logic Controller) is used to control industrial processing, which is similar to a computer and consists of central processing unit and memory and Input/Output units. PLC receives input information from auxiliary units such as sensors, switches, etc. and software processes data in memory and then sends commands to output units such as relays, motors, etc.The target section in Iodine production consists of 8 stages. In order to be sure automation works properly the system can be operated both manually and automatically. First PLC checks Manual/Automatic switch and in the case of automatic mode, PLC runs the program in memory and processing is done automatically. For this purpose, PLC takes the value of pressures and temperatures from analog inputs and after processing them it sends commands to digital output to activate valves or vacuum pumps or heaters. In this paper the following subjects are discussed: 1) Production of Iodine 123 2) PLC structure and auxiliary boards 3) Sensors and actuators and their connection to PLC 4) Software flowchart

  7. Iodine-131 Metaiodobenzylguanidine Therapy for Neuroblastoma: Reports So Far and Future Perspective

    Directory of Open Access Journals (Sweden)

    Daiki Kayano

    2015-01-01

    Full Text Available Neuroblastoma, which derives from neural crest, is the most common extracranial solid cancer in childhood. The tumors express the norepinephrine (NE transporters on their cell membrane and take in metaiodobenzylguanidine (MIBG via a NE transporter. Since iodine-131 (I-131 MIBG therapy was firstly reported, many trails of MIBG therapy in patients with neuroblastoma were performed. Though monotherapy with a low dose of I-131 MIBG could achieve high-probability pain reduction, the objective response was poor. In contrast, more than 12 mCi/kg I-131 MIBG administrations with or without hematopoietic cell transplantation (HCT obtain relatively good responses in patients with refractory or relapsed neuroblastoma. The combination therapy with I-131 MIBG and other modalities such as nonmyeloablative chemotherapy and myeloablative chemotherapy with HCT improved the therapeutic response in patients with refractory or relapsed neuroblastoma. In addition, I-131 MIBG therapy incorporated in the induction therapy was proved to be feasible in patients with newly diagnosed neuroblastoma. To expand more the use of MIBG therapy for neuroblastoma, further studies will be needed especially in the use at an earlier stage from diagnosis, in the use with other radionuclide formations of MIBG, and in combined use with other therapeutic agents.

  8. Insulin resistance is associated with impaired cardiac sympathetic innervation in patients with heart failure.

    Science.gov (United States)

    Paolillo, S; Rengo, G; Pellegrino, T; Formisano, R; Pagano, G; Gargiulo, P; Savarese, G; Carotenuto, R; Petraglia, L; Rapacciuolo, A; Perrino, C; Piscitelli, S; Attena, E; Del Guercio, L; Leosco, D; Trimarco, B; Cuocolo, A; Perrone-Filardi, P

    2015-10-01

    Insulin resistance (IR) represents, at the same time, cause and consequence of heart failure (HF) and affects prognosis in HF patients, but pathophysiological mechanisms remain unclear. Hyperinsulinemia, which characterizes IR, enhances sympathetic drive, and it can be hypothesized that IR is associated with impaired cardiac sympathetic innervation in HF. Yet, this hypothesis has never been investigated. Aim of the present observational study was to assess the relationship between IR and cardiac sympathetic innervation in non-diabetic HF patients. One hundred and fifteen patients (87% males; 65 ± 11.3 years) with severe-to-moderate HF (ejection fraction 32.5 ± 9.1%) underwent iodine-123 meta-iodobenzylguanidine ((123)I-MIBG) myocardial scintigraphy to assess sympathetic innervation and Homeostasis Model Assessment Insulin Resistance (HOMA-IR) evaluation to determine the presence of IR. From (123)I-MIBG imaging, early and late heart to mediastinum (H/M) ratios and washout rate were calculated. Seventy-two (63%) patients showed IR and 43 (37%) were non-IR. Early [1.68 (IQR 1.53-1.85) vs. 1.79 (IQR 1.66-1.95); P = 0.05] and late H/M ratio [1.50 (IQR 1.35-1.69) vs. 1.65 (IQR 1.40-1.85); P = 0.020] were significantly reduced in IR compared with non-IR patients. Early and late H/M ratio showed significant inverse correlation with fasting insulinemia and HOMA-IR. Cardiac sympathetic innervation is more impaired in patients with IR and HF compared with matched non-IR patients. These findings shed light on the relationship among IR, HF, and cardiac sympathetic nervous system. Additional studies are needed to clarify the pathogenetic relationship between IR and HF. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  9. Preliminary evaluation of the protocol scintigraphy of neuroendocrine tumor with metaiodobenzylguanidine (mIBG) labeled with {sup 123}I; Avaliacao preliminar do protocolo de cintilografia de tumores neuroendocrinos com meta-iodobenzilguanidina (mIBG) marcado com {sup 123}I

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Danillo M. [Hospital de Urgencia de Sergipe Gov. Joao Alves Filho, Aracaju, SE (Brazil); Mendes, Janaina Dutra Silvestre, E-mail: danillo_90@hotmail.com [Instituto Nacional de Cancer Jose Alencar Gomes da Silva, Rio de Janeiro, RJ (Brazil). Setor de Medicina Nuclear

    2014-04-15

    Neuroendocrine tumors have a property of capturing metaiodobenzylguanidine (mIBG) and because of this is possible to perform scintigraphy for diagnosis marking this molecule with {sup 123}I. However, {sup 123}I has some particularities, such as the release of X-ray low energy, which complicates the measurement of activity by activity meter, moreover emits a significant intensity of high energy gamma radiation, damaging the image quality. The acquisition protocol scintigraphy of neuroendocrine tumor was evaluated and the necessary recommendations for its optimization will be studied to ensure image quality with the least possible expense to the patient. (author)

  10. Study of the association between left ventricular diastolic impairment and cardiac autonomic neuropathy in diabetic patients using [123I] metaiodobenzylguanidine scintigraphy

    International Nuclear Information System (INIS)

    Suzuki, Rokuro; Tanaka, Shiro; Tojo, Osamu; Ishii, Tomofusa; Sato, Toshihiko; Fujii, Satoru; Tumura, Kei.

    1994-01-01

    The association between left ventricular (LV) diastolic dysfunction and myocardial MIBG accumulation was investigated. The subjects were 14 Type II diabetic patients who had no evidence of ischemic heat disease, LV hypertrophy or dilated cardiomyopathy as determined by exercise Tl-201 myocardial scintigraphy and echocardiography. In 14 diabetic patients, isovolumic relaxation time (IRT) was measured by M-mode echocardiography, and the subjects were subdivided into two groups: Group1, 8 patients with impaired left ventricular diastolic function (IRT≥80 msec), and Group 2, 6 patients with normal left ventricular diastolic function (IRT 123 I-MIBG myocardial scintigraphy was performed, and the myocardial accumulation of 123 I-MIBG was investigated. The ratio of myocardial to mediastinal MIBG uptake was significantly (p<0.01) lower in Group 1 than in Group 2. And scintigraphic defects were significantly (p<0.05) more numerous in Group 1 than in Group 2. Patients in Group 1 had a greater frequency of cardiac autonomic neuropathy evaluated by QTc interval and coefficient of variation of R-R interval, when compared with Group 2. These data suggest that, in diabetic patients with no evidence of ischemic heart disease, LV hypertrophy or dilated cardiomyopathy, impairment of left ventricular diastolic function is associated with cardiac autonomic neuropathy. (author)

  11. Improving the radiochemical purity determination of 123I-labeled metaiodobenzylguanidine

    International Nuclear Information System (INIS)

    Luciana Carvalheira; Paulo Bechara Dutra; Paula Fernandes de Aguiar

    2014-01-01

    The HPLC method originally applied at the Nuclear Engineering Institute (IEN) for the radiochemical purity determination of 123iodine labeled m-iodobenzylguanidine ( 123 I-mIBG) takes 18.5 min. The final product release also depends on this result, and to facilitate this stage, we aimed to decrease this analysis time. We also intended to use fewer toxic compounds, if feasible. The optimization approach used herein was a combination of factorial and mixture designs to study simultaneously the selected variables. Analysis time, resolution and chromatograms aspect were the measured responses. The qualitative analysis of these responses provided the best chromatographic separation conditions that were 52 mM KH 2 PO 4 in a solution of ethanol and water (1:1), applying a flow rate of 0.50 mL min -1 and C18 column (4.6 × 250 mm, 5 μm). These optimum conditions not only decreased the analysis time in 61 %, but also allowed the reduction of mobile phase toxicity. To assure reliable data, method validation was performed for these conditions. The method has proved its specificity, the detection limit found was 3.70 × 10 -4 MBq mL -1 and the quantification limit has corresponded to 1.11 × 10 -3 MBq mL -1 . Repeatability and intermediate precision has not exceeded 3 and 5 %, respectively, and the accuracy has matched the interval of 95-105 %. This new method has been routinely applied in the radiochemical purity determination of 123 I-mIBG at IEN. (author)

  12. Clinical value of lung uptake of iodine-123 metaiodobenzylguanidine (MIBG), a myocardial sympathetic nerve imaging agent, in patients with chronic heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Mu, Xiuli; Hasegawa, Shinji; Yoshioka, Jun [Osaka Univ., Suita (Japan). Graduate School of Medicine] (and others)

    2001-10-01

    This study investigated the clinical value of I-123 MIBG pulmonary accumulation and washout in patients with chronic heart failure (CHF). Nineteen patients with CHF and 15 normal volunteers (NL) were included. The uptake ratio of heart to mediastinum (H/M), that of lung fields to mediastinum (L/M), and washout rate (WR) of the heart and lung fields were calculated in anterior planar images and compared with results of echocardiography and cardiac catheterization. In the CHF group, the lung uptake in delayed images increased and lung WR was decreased, suggesting pulmonary endothelial lesions. Furthermore, there was a negative correlation between right and left lung WR and pulmonary arterial diastolic pressure (PA(D)) and pulmonary arterial systolic pressure (PA(S)) in the CHF group. Since the WR of MIBG reflected PA, it may be used as an index of severity of cardiac dysfunction. (author)

  13. Ocular melanoma: Detection using iodine-123-iodoamphetamine and SPECT imaging

    International Nuclear Information System (INIS)

    Dewey, S.H.; Leonard, J.C.

    1990-01-01

    Uptake of iodine-123-iodoamphetamine has been demonstrated in malignant melanoma using planar imaging techniques and has been used to detect an ocular melanoma at 12 hr postinjection. Using SPECT technique, an ocular melanoma is identified in a 64-yr-old male at 1 hr postinjection

  14. Efeito do carvedilol a curto prazo na atividade simpática cardíaca pela cintilografia com 123I-MIBG Effects of short-term carvedilol on the cardiac sympathetic activity assessed by 123I-MIBG scintigraphy

    Directory of Open Access Journals (Sweden)

    Sandra Marina Ribeiro de Miranda

    2010-03-01

    Full Text Available FUNDAMENTO: Alterações autonômicas na insuficiência cardíaca estão associadas a um aumento da morbimortalidade. Vários métodos não invasivos têm sido empregados para avaliar a função simpática, incluindo a imagem cardíaca com 123I-MIBG. OBJETIVO: Avaliar a atividade simpática cardíaca, por meio da cintilografia com 123I-MIBG, antes e após três meses de terapia com carvedilol em pacientes com insuficiência cardíaca com fração de ejeção do VE BACKGROUND: Autonomic alterations in heart failure are associated with an increase in morbimortality. Several noninvasive methods have been employed to evaluate the sympathetic function, including the Meta-Iodobenzylguanidine (123I-MIBG scintigraphy imaging of the heart. OBJECTIVE: to evaluate the cardiac sympathetic activity through 123I-MIBG scintigraphy, before and after three months of carvedilol therapy in patients with heart failure and left ventricular ejection fraction (LVEF < 45%. PATIENTS AND METHODS: Sixteen patients, aged 56.3 ± 12.6 years (11 males, with a mean LVEF of 28% ± 8% and no previous use of beta-blockers were recruited for the study. Images of the heart innervation were acquired with 123I-MIBG, and the serum levels of catecholamines (epinephrine, dopamine and norepinephrine were measured; the radioisotope ventriculography (RIV was performed before and after a three-month therapy with carvedilol. RESULTS: Patients' functional class showed improvement: before the treatment, 50% of the patients were FC II and 50% were FC III. After 3 months, 7 patients were FC I (43.8% and 9 were FC II (56.2%, (p = 0.0001. The mean LVEF assessed by RIV increased from 29% to 33% (p = 0.017. There was no significant variation in cardiac adrenergic activity assessed by 123I-MIBG (early and late resting images and washout rate. No significant variation was observed regarding the measurement of catecholamines. CONCLUSION: The short-term treatment with carvedilol promoted the clinical

  15. Evaluation of the sympathetic nervous system in silent ischemia with 123I-metaiodobenzylguanidine (MIBG)

    International Nuclear Information System (INIS)

    Guertner, C.; Schacherer, C.; Krause, B.J.; Zickmann, J.; Klepzig, H. Jr.; Hoer, G.

    1996-01-01

    Stress and rest myocardial perfusion scintigraphy using either Thallium-201 or 99m Tc-isonitrile was performed in SPECT technique in order to localize ischemia or scar associated perfusion defects. 15 min and 4 h p.i. static anterior 123 I-MIBG uptake was acquired. In order to localize norepinephrine depletion 4 h p.i. additional 123 I-MIBG SPECT acquistion was performed. Incidence of arrhythmias was investigated by Holter ECG. Patients with diabetes mellitus were excluded. SPECT images showed in all patients regional 123 I-MIBG depletion which corresponded with scintigraphically infarcted or ischemic regions. Well perfused myocardial regions matched with regular 123 I-MIBG utpake. There was no evidence of increased arrhythmias in long-term ECG. The finding of regular 123 I-MIBG uptake in well-perfused myocardium and infarction- or ischemia-associated regional 123 I-MIBG depletion confirms that silent ischemia is not caused by a global sympathetic nervous dysfunction in a sense of cardiac polyneuropathy. (orig.) [de

  16. The utility of segmental analysis in cardiac I-123 MIBG SPECT in Parkinson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Soo Hyun; Yoon, Joon Kee; Yoon, Jung Han; Lee, Su Jin; Jo, Kyung Soo; Lee, Dong Hyun; An, Young Sil [Ajou University School of Medicine, Suwon (Korea, Republic of)

    2015-12-15

    Cardiac images using I-123 metaiodobenzylguanidine (MIBG) are widely used to evaluate cardiac sympathetic denervation in Parkinson’s disease (PD). The aim of this study was to evaluate the utility of segmental analysis on cardiac MIBG SPECT in PD patients. In total, 36 patients with PD (n = 26) or essential tremor (ET, n = 10) who underwent MIBG cardiac SPECT were enrolled. The heart-to-mediastinum (H/M) ratios of MIBG uptake were acquired on planar images. For the segmental analysis of SPECT images, we evaluated the summed defect score (SDS) using a 17-segment model. The diagnostic abilities of H/M ratios and segmental parameters on MIBG SPECT were assessed by ROC curve analysis. The H/M ratios were significantly lower in PD than in ET patients (p < 0.05). On segmental analysis, SDS was significantly higher in PD patients than in the ET group (7.04 ± 4.09 vs. 2.90 ± 2.80; p = 0.006). The defect score of the anteroseptal region showed a significant difference between the groups (p = 0.002). The ROC analysis suggested only SDS (AUC = 0.785, p = 0.0003) and defect scores in the anteroseptal (AUC = 0.800, p < 0.0001) and inferior (AUC = 0.667, p = 0.013) regions showed significant diagnostic ability to differentiate PD from ET. Segmental parameters from cardiac MIBG SPECT images can provide additional information to differentiate PD from ET patients. Beyond H/M ratios from planar images, we recommend an MIBG SPECT study to evaluate sympathetic denervation in PD.

  17. Prognostic value of repeated {sup 123}I-metaiodobenzylguanidine imaging in patients with dilated cardiomyopathy with congestive heart failure before and after optimized treatments. Comparison with neurohumoral factors

    Energy Technology Data Exchange (ETDEWEB)

    Matsui, Toshiki; Tsutamoto, Takayoshi; Maeda, Keiko; Kusukawa, Junya; Kinoshita, Masahiko [Shiga Univ. of Medical Science, Otsu (Japan)

    2002-06-01

    The present study was undertaken to assess whether repeated measurement of cardiac {sup 123}I-metaiodobenzylguanidine (MIBG) imaging parameters before and after optimized treatments is useful for predicting the prognosis of patients with congestive heart failure (CHF) resulting from dilated cardiomyopathy (DCM). The subjects were 85 consecutive patients with DCM who had a left ventricular ejection fraction (LVEF) of less than 45%. The MIBG and the concentrations of neurohumoral factors were measured at baseline and after 6 months of optimized treatments. Cox proportional hazards analysis was performed to assess the various parameters before and after treatment. Twenty-three patients had a cardiac event (12 died; 11 hospitalized) during a mean follow-up period of 2 years. Although there was no difference between the baseline heart to mediastinum (H/M) ratio measured by MIBG between survivors and nonsurvivors, the H/M ratio was significantly decreased in nonsurvivors after 6 months. Multivariate analysis revealed that a high plasma concentration of brain natriuretic peptide level after 6 months (p=0.0049) and absolute changes in the H/M ratio (p=0.0046) were independent predictors of mortality. Comparison of the H/M ratio on MIBG imaging before and after optimized additional treatment provided useful information for predicting mortality and was independent of clinical and neurohumoral factors previously shown to be associated with poor prognosis in patients with DCM. (author)

  18. Iodine 123-antipyrine. A diffusible tracer for brain exploration

    International Nuclear Information System (INIS)

    Dantonel-Mathieu, Evelyne.

    1978-09-01

    Iodine 123-labelled iodoantipyrine is a liposoluble diffusible tracer which crosses the blood-brain barrier intact. Its build-up in brain tissue is proportional to the regional blood flow. Its behavior was studied in undervascularised brain lesions and in cases where research with traditional radioactive tracers (99mTc and its different vectors for example) has proved limited. Because of the great diffusibility of iodoantipyrine a brain parenchyma image is obtained within minutes after its injection, and this by the use of a non-invasive technique and under good gamma-camera exploration conditions. 81 brain explorations including 11 standards have been carried out on subjects averaging 51,2 years old; these examinations took place in three nuclear medicine centres. The 123 I iodoantipyrine used in each nuclear medicine centre is supplied by the CEA. Iodoantipyrine is labelled with a good yield (>98%) checked by chromatography by means of a CEA kit. After intraveinous injection of 4 to 6 mCi iodine-123 iodoantipyrine, a dynamic study (from 0 to 60 seconds) of the tracer passage in the brain tissue may be followed by static images taken in the next minutes according to a standard procedure. The table of results shows the major interest of this tracer for the exploration of vascular accidents with ischemic lesions, especially in the early phase of the accident. The lesion appears as a hypoactive zone and this lack of perfusion lasts for some minutes after the injection [fr

  19. Relationship between late ventricular potentials and myocardial {sup 123}I-metaiodobenzylguanidine scintigraphy in patients with dilated cardiomyopathy with mild to moderate heart failure: results of a prospective study of sudden death events

    Energy Technology Data Exchange (ETDEWEB)

    Kasama, Shu [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Gunma (Japan); Cardiovascular Hospital of Central Japan (Kitakanto Cardiovascular Hospital), Department of Cardiovascular Medicine, Gunma (Japan); Toyama, Takuji; Kaneko, Yoshiaki; Kurabayashi, Masahiko [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Gunma (Japan); Iwasaki, Toshiya; Sumino, Hiroyuki; Kumakura, Hisao; Minami, Kazutomo; Ichikawa, Shuichi [Cardiovascular Hospital of Central Japan (Kitakanto Cardiovascular Hospital), Department of Cardiovascular Medicine, Gunma (Japan); Matsumoto, Naoya [Nihon University School of Medicine, Department of Cardiology, Tokyo (Japan); Sato, Yuichi [Health Park Clinic, Department of Imaging, Gunma (Japan)

    2012-06-15

    Late ventricular potentials (LPs) are considered to be useful for identifying patients with heart failure at risk of developing ventricular arrhythmias. {sup 123}I-metaiodobenzylguanidine (MIBG) scintigraphy, which is used to evaluate cardiac sympathetic activity, has demonstrated cardiac sympathetic denervation in patients with malignant ventricular tachyarrhythmias. This study was undertaken to clarify the relationship between LPs and {sup 123}I-MIBG scintigraphy findings in patients with dilated cardiomyopathy (DCM). A total of 56 patients with DCM were divided into an LP-positive group (n = 24) and an LP-negative group (n = 32). During the compensated period, the delayed heart/mediastinum count (H/M) ratio, delayed total defect score (TDS), and washout rate (WR) were determined from {sup 123}I-MIBG images and plasma brain natriuretic peptide (BNP) concentrations were measured. Left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV), and left ventricular ejection fraction (LVEF) were simultaneously determined by echocardiography. LVEDV, LVESV, LVEF and plasma BNP concentrations were similar in the two groups. However, TDS was significantly higher (35 {+-} 8 vs. 28 {+-} 6, p < 0.005), the H/M ratio was significantly lower (1.57 {+-} 0.23 vs. 1.78 {+-} 0.20, p < 0.005), and the WR was significantly higher (60 {+-} 14% vs. 46 {+-} 12%, p < 0.001) in the LP-positive than in the LP-negative group. The average follow-up time was 4.5 years, and there were nine sudden deaths among the 56 patients (16.1%). In logistic regression analysis, the incidences of sudden death events were similar in those LP-negative with WR <50%, LP-negative with WR {>=}50% and LP-positive with WR <50% (0%, 10.0% and 14.3%, respectively), but was significantly higher (41.2%) in those LP-positive with WR {>=}50% (p < 0.01, p < 0.05, and p < 0.05, respectively). The present study demonstrated that the values of cardiac {sup 123}I-MIBG scintigraphic parameters

  20. Cardiac metaiodobenzylguanidine activity can predict the long-term efficacy of angiotensin-converting enzyme inhibitors and/or beta-adrenoceptor blockers in patients with heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Nakata, Tomoaki; Wakabayashi, Takeru; Kyuma, Michifumi; Takahashi, Toru; Tsuchihashi, Kazufumi; Shimamoto, Kazuaki [Sapporo Medical University School of Medicine, Second Department of Internal Medicine (Cardiology), Sapporo (Japan)

    2005-02-01

    Although the benefits of treatment with angiotensin-converting enzyme (ACE) inhibitors and beta-blockers are well known, no method has as yet been established to predict the efficacy of drug therapy. This study tested whether cardiac{sup 123}I-metaiodobenzylguanidine (MIBG) activity is of prognostic value and can predict the improvement in heart failure patients resulting from treatment with ACE inhibitors and/or beta-blockers. Following quantification of the heart-to-mediastinum ratio (HMR) of MIBG activity, 88 patients with heart failure who were treated with ACE inhibitors and/or beta-blockers (treated group) and 79 patients with heart failure who were treated conventionally without the aforementioned agents, and who served as controls, were followed up for 43 months with a primary endpoint of cardiac death. The treated group had a significantly lower prevalence of cardiac death and a significantly lower mortality at 5 years compared with the control group (15% vs 37% and 21% vs 42%, p<0.05, respectively). Multivariate analysis revealed that significant predictors were HMR, age, nitrate use and ventricular tachycardia for the treated group, and HMR, nitrate use and NYHA class for the control group. The drug treatment significantly reduced mortality from 36% to 12% when HMR was 1.53 or more and from 53% to 37% when HMR was less than 1.53. The reduction in risk of mortality within 5 years in patients without a severe MIBG defect (67%) was twice that in patients with such a defect (32%) (p<0.05). The reduction in mortality risk achieved by using ACE inhibitors and/or beta-blockers is associated with the severity of impairment of cardiac MIBG uptake. Cardiac MIBG activity can consequently be of long-term prognostic value in predicting the effectiveness of such treatment in patients with heart failure. (orig.)

  1. Cardiac metaiodobenzylguanidine activity can predict the long-term efficacy of angiotensin-converting enzyme inhibitors and/or beta-adrenoceptor blockers in patients with heart failure

    International Nuclear Information System (INIS)

    Nakata, Tomoaki; Wakabayashi, Takeru; Kyuma, Michifumi; Takahashi, Toru; Tsuchihashi, Kazufumi; Shimamoto, Kazuaki

    2005-01-01

    Although the benefits of treatment with angiotensin-converting enzyme (ACE) inhibitors and beta-blockers are well known, no method has as yet been established to predict the efficacy of drug therapy. This study tested whether cardiac 123 I-metaiodobenzylguanidine (MIBG) activity is of prognostic value and can predict the improvement in heart failure patients resulting from treatment with ACE inhibitors and/or beta-blockers. Following quantification of the heart-to-mediastinum ratio (HMR) of MIBG activity, 88 patients with heart failure who were treated with ACE inhibitors and/or beta-blockers (treated group) and 79 patients with heart failure who were treated conventionally without the aforementioned agents, and who served as controls, were followed up for 43 months with a primary endpoint of cardiac death. The treated group had a significantly lower prevalence of cardiac death and a significantly lower mortality at 5 years compared with the control group (15% vs 37% and 21% vs 42%, p<0.05, respectively). Multivariate analysis revealed that significant predictors were HMR, age, nitrate use and ventricular tachycardia for the treated group, and HMR, nitrate use and NYHA class for the control group. The drug treatment significantly reduced mortality from 36% to 12% when HMR was 1.53 or more and from 53% to 37% when HMR was less than 1.53. The reduction in risk of mortality within 5 years in patients without a severe MIBG defect (67%) was twice that in patients with such a defect (32%) (p<0.05). The reduction in mortality risk achieved by using ACE inhibitors and/or beta-blockers is associated with the severity of impairment of cardiac MIBG uptake. Cardiac MIBG activity can consequently be of long-term prognostic value in predicting the effectiveness of such treatment in patients with heart failure. (orig.)

  2. Iodine 123-labeled meta-iodobenzylguanidine myocardial scintigraphy in the cases of idiopathic Parkinson`s disease, multiple system atrophy, and progressive supranuclear palsy

    Energy Technology Data Exchange (ETDEWEB)

    Yoshita, Mitsuhiro; Hayashi, Michiyuki; Hirai, Shunsaku [Tokyo Metropolitan Neurological Hospital (Japan)

    1997-06-01

    To investigate cardiac sympathetic function in Parkinson`s disease (PD), multiple system atrophy (MSA), and progressive supranuclear palsy (PSP), {sup 123}I-MIBG myocardial scintigraphy was performed in 25 patients with PD, 25 patients with MSA, 14 patients with PSP, and 20 control subjects. In planar imaging studies, the heart-to-mediastinum average count ratio (H/M) was calculated for both early and delayed images. The mean value of H/M in patients with PD was significantly lower than in those with MSA, PSP, or no disease. Regardless of disease severity or intensity of anti-parkinsonian pharmacotherapy, mean values for H/M were always low in patients with PD. The mean values of H/M in patients with MSA and PSP were significantly lower than in controls. There was no significant difference between the mean value of H/M in MSA with orthostatic hypotension (OH) and that in MSA without OH, and also there was no significant difference between the mean value of H/M in MSA with striatonigral degeneration and that in MSA with olivopontocerebellar atrophy. Although the mean value of H/M in PSP with amitriptyline treatment was significantly lower than that in PSP patients without amitriptyline treatment, there was no significant difference between the mean value of H/M in PSP patients without amitriptyline treatment and that in controls. There was no correlation between H/M and disease duration in those three akinetic-rigid disorders that we have studied here. Thus, PD may have an abnormality of cardiac sympathetic function which has not been detected by previous cardiovascular autonomic studies. Particularly in early stages, {sup 123}I-MIBG myocardial scintigraphy may help to differentiate PD from MSA and PSP. (K.H.)

  3. Prognostic value of sympathetic innervation and cardiac asynchrony in dilated cardiomyopathy

    International Nuclear Information System (INIS)

    Manrique, Alain; Hitzel, Anne; Vera, Pierre; Bernard, Mathieu; Bauer, Fabrice; Menard, Jean-Francois; Sabatier, Remi; Jacobson, Arnold; Agostini, Denis

    2008-01-01

    The purpose of the study is to examine prognostic values of cardiac I-123 metaiodobenzylguanidine (MIBG) uptake and cardiac dyssynchrony in patients with dilated cardiomyopathy (DCM). Ninety-four patients with non-ischemic DCM underwent I-123 MIBG imaging for assessing cardiac sympathetic innervation and equilibrium radionuclide angiography. Mean phase angles and SD of the phase histogram were computed for both right ventricular (RV) and left ventricular (LV). Phase measures of interventricular (RV-LV) and intraventricular (SD-RV and SD-LV) asynchrony were computed. Most patients were receiving beta-blockers (89%) and angiotensin-converting enzyme inhibitors (88%). One patient (1%) was lost to follow-up, six had cardiac death (6.4%), eight had heart transplantation (8.6%), and seven had unplanned hospitalization for heart failure (7.5%; mean follow-up: 37 ± 16 months). Patients with poor clinical outcome were older, had higher The New York Heart Association functional class, impaired right ventricular ejection fraction and left ventricular ejection fraction, and impaired cardiac I-123 MIBG uptake. On multivariate analysis, I-123 MIBG heart-to-mediastinum (H/M) uptake ratio <1.6 was the only predictor of both primary (cardiac death or heart transplantation, RR = 7.02, p < 0.01) and secondary (cardiac death, heart transplantation, or recurrent heart failure, RR = 8.10, p = 0.0008) end points. In patients receiving modern medical therapy involving beta-blockers, I-123 MIBG uptake, but not intra-LV asynchrony, was predictive of clinical outcome. The impact of beta-blockers on the prognostic value of ventricular asynchrony remains to be clarified. (orig.)

  4. Synthesis of iodine-123 labelled analogues of imidazenil and ethyl-imidazenil for studying benzodiazepine receptors using SPECT

    International Nuclear Information System (INIS)

    Katsifis, A.; Mattner, F.; Dikic, B.; Najdovski, L.; Kassiou, M.

    1996-01-01

    The [ 123 I]iodinated analogues of the benzodiazepine receptor partial agonist imidazenil and N-ethyl imidazenil have been synthesised for the study of the central benzodiazepine receptor using SPECT. [ 123 I]Iodomidazenil and [ 123 I]N-ethyliodoimidazenil were prepared by nucleophilic bromine-iodine exchange in acetic acid at 150 o . The products were purified by semi-preparative reverse-phase HPLC with average radiochemical yields of 80% in a total synthesis time of 80 minutes. The specific activity was determined to be greater than 2500 Ci/mmol. The radiochemical and chemical purity assessed by radio-TLC and HPLC were found to be 98%. Alternatively, iododestannylation reactions via the trimethyltin precursors with Na[ 123 I] in the presence of Chloramine-T or peracetic acid resulted in yields of only 20-25% with the bulk of activity being lost as volatile methyl [ 123 I]iodide. (author)

  5. Production of high specific activity 123I for protein iodination for medical use

    International Nuclear Information System (INIS)

    Legoux, Y.; Cieur, M.; Crouzel, C.; Syrota, A.

    1985-01-01

    Iodine-123 is produced via xenon-133 by irradiation of a sodium iodide target with 108 MeV deuterons from the synchrocyclotron of IPN. The on-line production method is described. The specific activity of the iodine is determined by neutron activation analysis and by a radioimmunological method. The conditions labelling different proteins (insulin, angiotensin) are given and also the purification method to obtain a product ready for injection to patients. (author)

  6. Functional imaging in phaeochromocytoma and neuroblastoma with 68Ga-DOTA-Tyr3-octreotide positron emission tomography and 123I-metaiodobenzylguanidine

    International Nuclear Information System (INIS)

    Kroiss, Alexander; Putzer, Daniel; Uprimny, Christian; Decristoforo, Clemens; Gabriel, Michael; Warwitz, Boris; Waitz, Dietmar; Kendler, Dorota; Virgolini, Irene Johanna; Santner, Wolfram; Kranewitter, Christof

    2011-01-01

    68 Ga-DOTA-Tyr 3 -octreotide positron emission tomography ( 68 Ga-DOTA-TOC PET) has proven to be superior to 111 In-DTPA-D-Phe 1 -octreotide ( 111 In-octreotide) planar scintigraphy and SPECT imaging in neuroendocrine tumours (NETs). Because of these promising results, we compared the accuracy of 123 I-metaiodobenzylguanidine ( 123 I-MIBG) imaging with PET in the diagnosis and staging of metastatic phaeochromocytoma and neuroblastoma, referring to radiological imaging as reference standard. Three male and eight female patients (age range 3 to 68 years) with biochemically and histologically proven disease were included in this study. Three male and three female patients were suffering from phaeochromocytoma, and five female patients from neuroblastoma. Comparative evaluation included morphological imaging with CT or MRI, functional imaging with 68 Ga-DOTA-TOC PET and 123 I-MIBG imaging. Imaging results were analysed on a per-patient and on a per-lesion basis. On a per-patient basis, both 68 Ga-DOTA-TOC and 123 I-MIBG showed a sensitivity of 100%, when compared with anatomical imaging. In phaeochromocytoma patients, on a per-lesion basis, the sensitivity of 68 Ga-DOTA-TOC was 91.7% and that of 123 I-MIBG was 63.3%. In neuroblastoma patients, on a per-lesion basis, the sensitivity of 68 Ga-DOTA-TOC was 97.2% and that of 123 I-MIBG was 90.7%. Overall, in this patient cohort, 68 Ga-DOTA-TOC PET identified 257 lesions, anatomical imaging identified 216 lesions, and 123 I-MIBG identified only 184 lesions. In this patient group, the overall sensitivity of 68 Ga-DOTA-TOC PET on a lesion basis was 94.4% (McNemar p 123 I-MIBG was 76.9% (McNemar p 68 Ga-DOTA-TOC PET may be superior to 123 I-MIBG gamma-scintigraphy and even to the reference CT/MRI technique in providing particularly valuable information for pretherapeutic staging of phaeochromocytoma and neuroblastoma. (orig.)

  7. Functional imaging in phaeochromocytoma and neuroblastoma with 68Ga-DOTA-Tyr 3-octreotide positron emission tomography and 123I-metaiodobenzylguanidine.

    Science.gov (United States)

    Kroiss, Alexander; Putzer, Daniel; Uprimny, Christian; Decristoforo, Clemens; Gabriel, Michael; Santner, Wolfram; Kranewitter, Christof; Warwitz, Boris; Waitz, Dietmar; Kendler, Dorota; Virgolini, Irene Johanna

    2011-05-01

    (68)Ga-DOTA-Tyr(3)-octreotide positron emission tomography ((68)Ga-DOTA-TOC PET) has proven to be superior to (111)In-DTPA-D-Phe(1)-octreotide ((111)In-octreotide) planar scintigraphy and SPECT imaging in neuroendocrine tumours (NETs). Because of these promising results, we compared the accuracy of (123)I-metaiodobenzylguanidine ((123)I-MIBG) imaging with PET in the diagnosis and staging of metastatic phaeochromocytoma and neuroblastoma, referring to radiological imaging as reference standard. Three male and eight female patients (age range 3 to 68 years) with biochemically and histologically proven disease were included in this study. Three male and three female patients were suffering from phaeochromocytoma, and five female patients from neuroblastoma. Comparative evaluation included morphological imaging with CT or MRI, functional imaging with (68)Ga-DOTA-TOC PET and (123)I-MIBG imaging. Imaging results were analysed on a per-patient and on a per-lesion basis. On a per-patient basis, both (68)Ga-DOTA-TOC and (123)I-MIBG showed a sensitivity of 100%, when compared with anatomical imaging. In phaeochromocytoma patients, on a per-lesion basis, the sensitivity of (68)Ga-DOTA-TOC was 91.7% and that of (123)I-MIBG was 63.3%. In neuroblastoma patients, on a per-lesion basis, the sensitivity of (68)Ga-DOTA-TOC was 97.2% and that of (123)I-MIBG was 90.7%. Overall, in this patient cohort, (68)Ga-DOTA-TOC PET identified 257 lesions, anatomical imaging identified 216 lesions, and (123)I-MIBG identified only 184 lesions. In this patient group, the overall sensitivity of (68)Ga-DOTA-TOC PET on a lesion basis was 94.4% (McNemar p<0.0001) and that of (123)I-MIBG was 76.9% (McNemar p<0.0001). Our analysis in this relatively small patient cohort indicates that (68)Ga-DOTA-TOC PET may be superior to (123)I-MIBG gamma-scintigraphy and even to the reference CT/MRI technique in providing particularly valuable information for pretherapeutic staging of phaeochromocytoma and

  8. Iodine-123 phenylpentadecanoic acid: detection of acute myocardial infarction and injury in dogs using an iodinated fatty acid and single-photon emission tomography

    International Nuclear Information System (INIS)

    Rellas, J.S.; Corbett, J.R.; Kulkarni, P.

    1983-01-01

    The ability of an iodinated fatty acid, iodine-123 phenylpentadecanoic acid (1-123 PPA), and single-photon emission computed tomography (SPECT) to detect myocardium injured by temporary or permanent coronary arterial occlusion was evaluated. In 5 control dogs, 11 dogs that underwent 90 to 120 minutes of fixed left anterior descending coronary artery (LAD) occlusion, and 8 dogs that underwent 90 minutes of temporary LAD occlusion and up to 90 minutes of reflow, 2 to 6 mCi of I-123 PPA were injected and the dogs were imaged with SPECT. Control dogs showed relatively uniform uptake and clearance of I-123 PPA in similar left ventricular (LV) regions. Dogs with permanent LAD occlusion were identified by computer algorithm as having regions of decreased I-123 PPA uptake in the infarct-related area and a reduced rate of I-123 PPA clearance (-9.4% in infarct sectors [washin], +3.7% in sectors adjacent to the area of infarction, and +15.4% in control LV sectors [p less than 0.01]). Dogs with temporary LAD occlusion and reperfusion had decreased clearance of I-123 PPA from the regions with infarction; I-123 PPA clearance was -5.2 +/- 16.4% in infarct sectors, 12.7 +/- 7.4% in periinfarct zones, and 30.4 +/- 12% in control LV regions. These data demonstrate that tomographic analysis of I-123 PPA uptake and clearance permits the relatively noninvasive detection of LV myocardium injured by permanent or temporary LAD occlusion and reperfusion

  9. I-123-mIBG myocardial imaging for assessment of risk for a major cardiac event in heart failure patients: insights from a retrospective European multicenter study

    Energy Technology Data Exchange (ETDEWEB)

    Agostini, Denis [CHU Cote de Nacre, Caen (France); Verberne, Hein J. [Academic Medical Centre, Amsterdam (Netherlands); Burchert, Wolfgang [Ruhr University Bochum, Institute of Radiology, Nuclear Medicine and Molecular Imaging, Heart and Diabetes Center NRW, Bad Oeyenhausen (Germany); Knuuti, Juhani [Turku University Central Hospital, Turku (Finland); Povinec, Pavol [Comenius University School of Medicine, Bratislava (Slovakia); Sambuceti, Gianmario [University of Genova, Genova (Italy); Unlu, Mustafa [Gazi University, Ankara (Turkey); Estorch, Montserrat [Hospital Sant Pau, Barcelona (Spain); Banerjee, Gopa; Jacobson, Arnold F. [GE Healthcare, Princeton, NJ (United States)

    2008-03-15

    Single-center experiences have shown that myocardial meta-iodobenzylguanidine (mIBG) uptake has prognostic value in heart failure (HF) patients. To verify these observations using a rigorous clinical trial methodology, a retrospective review and prospective quantitative reanalysis was performed on a series of cardiac {sup 123}I-mIBG scans acquired during a 10-year period at six centers in Europe. {sup 123}I-mIBG scans obtained on 290 HF patients [(262 with left ventricular ejection fraction (LVEF) < 50%)] from 1993 to 2002 were reanalyzed using a standardized methodology to determine the heart-to-mediastinum ratio (H/M) on delayed planar images. All image results were verified by three independent reviewers. Major cardiac events [MCEs; cardiac death, cardiac transplant, potentially fatal arrhythmia (including implantable cardioverter-defibrillator discharge)] during 24-month follow-up were confirmed by an adjudication committee. MCEs occurred in 67 patients (26%): mean H/M ratio was 1.51 {+-} 0.30 for the MCE group and 1.97 {+-} 0.54 for the non-MCE group (p < 0.001). Two-year event-free survival using an optimum H/M ratio threshold of 1.75 was 62% for H/M ratio less than 1.75, 95% for H/M ratio greater than or equal to 1.75 (p < 0.0001). Logistic regression showed H/M ratio and LVEF as the only significant predictors of MCE. Using the lower and upper H/M quartiles of 1.45 and 2.17 as high- and very low-risk thresholds, 2-year event-free survival rates were 52% and 98%, respectively. Among patients with LVEF {<=} 35% and H/M {>=} 1.75 (n = 73), there were nine MCEs because of progressive HF and only one because of an arrhythmia. Application of a clinical trial methodology via the retrospective reanalysis of {sup 123}I-mIBG images confirms the previously reported prognostic value of this method in HF patients, including potential identification of a quantitative threshold for low risk for cardiac mortality and potentially fatal ventricular arrhythmias. (orig.)

  10. Iodine-123-labelled serum amyloid P component scintigraphy in amyloidosis

    International Nuclear Information System (INIS)

    Saile, R.; Deveaux, M.; Marchandise, X.; Duquesnoy, B.

    1993-01-01

    This study describes the results of scintigraphy with iodine-123-labelled serum amyloid P component (SAP) as a means of establishing the distribution of organ involvement in amyloidosis. The significance of 123 I-SAP scans obtained in 15 patients with biopsy-proven AA or AL amyloidosis is discussed. Biopsy-proven amyloidosis was typically confirmed by scintigraphy, though such confirmation was not obtained in the kidneys in six patients with histological proof of extensive renal amyloid deposition. This lack of uptake may have been due to the accumulation of a major part of the 123 I-SAP in the spleen and/or liver. Twenty-four hour whole-body retention of 123 I-SAP was higher in patients with amyloidosis than in controls. Twenty-four hour tracer accumulation of the radioactivity in the extravascular compartment was notably greater in patients than in controls and appeared to be a good diagnostic criterion. We conclude that 123 I-SAP scintigraphy may be helpful for the evaluation of organ involvement not only in patients with biopsy-proven amyloidosis but also when a biopsy cannot be performed or when a strong suspicion of amyloidosis exists in spite of repeated negative biopsises. (orig.)

  11. Meta-iodobenzylguanidine synthesis and labelling with iodine-131

    International Nuclear Information System (INIS)

    Miranda, J.; Herrera, J.; Robles, A.; Caballero, J.; Portilla, A.; Ticona, L.

    1997-01-01

    Meta-iodo-benzylguanidine (MIBG) synthesis is carried out through m-iodo benzylamine condensation and subsequent formation of the hemisulfate salt. The synthesized product is characterized and identified by IR spectroscopy and m.p. determination. Acute toxicity tests conducted in mice demonstrated that the synthesized product is not toxic. MIBG hemisulfate labelling methods with I-131 is carried out by nucleophilic isotopic exchange; the reaction is catalyzed with cooper sulfate in the presence of ammonium sulfate at temperatures ranging between 140 and 150 o C . Biological distribution tests in wistar rats present an average value of 1,54% of injected dose/organ gram in suprarenal glands. These values show promise for the application of this radiopharmaceutical in radiodiagnosis of suprarenal tumors and procurement of adrenal medulla, myocardium and salivary gland images

  12. Radionuclide therapy of Sipple syndrome using iodine-131 metaiodobenzylguanidine

    International Nuclear Information System (INIS)

    Furusawa, Mitsuhiro; Shimomura, Osamu; Tomiguchi, Seiji; Hirota, Yoshihisa; Takahashi, Mutsumasa; Yamauchi, Jyoji; Iwaoka, Daisuke; Satoh, Tatsuo

    1992-01-01

    A 40-years-old female who had lung and liver metastases from malignant pheochromocytoma was treated with 3.7 GBq 131 I-MIBG (metaiodobenzylguanidine). After the treatment, 131 I-MIBG showed increased uptake in the metastatic lesions of the lung and liver. The size of tumor was no significant change on CT and MRI, but the intensity of liver metastases decreased gradually on MRI. Prior to the treatment, the levels of adrenaline and noradrenaline were high. One to three days after treatment, the level of these laboratory data further increased, but they gradually decreased in 1 to 3 months. These changes may be due to necrosis of tumor tissue. (author)

  13. Production of high specific activity /sup 123/I for protein iodination for medical use

    Energy Technology Data Exchange (ETDEWEB)

    Legoux, Y; Cieur, M [Paris-11 Univ., 91 - Orsay (France). Inst. de Physique Nucleaire; Goutheraud, R; Drouet, J [Centre National de Transfusion Sanguine, 75 - Paris (France); Crouzel, C; Syrota, A [CEA, 91 - Orsay (France). Service Hospitalier Frederic Joliot

    1985-01-01

    Iodine-123 is produced via xenon-133 by irradiation of a sodium iodide target with 108 MeV deuterons from the synchrocyclotron of IPN. The on-line production method is described. The specific activity of the iodine is determined by neutron activation analysis and by a radioimmunological method. The conditions labelling different proteins (insulin, angiotensin) are given and also the purification method to obtain a product ready for injection to patients.

  14. Usefulness of {sup 123}I-metaiodobenzylguanidine myocardial scintigraphy for predicting the effectiveness of {beta}-blockers in patients with dilated cardiomyopathy from the standpoint of long-term prognosis

    Energy Technology Data Exchange (ETDEWEB)

    Fujimoto, Shinichiro; Inoue, Aritomo; Hisatake, Shinji; Yamashina, Shohei; Yamashina, Hisayo; Nakano, Hajime; Yamazaki, Junichi [Toho University School of Medicine, Division of Cardiovascular Medicine, Department of Internal Medicine, Ohmori Hospital, Tokyo (Japan)

    2004-10-01

    The usefulness of {sup 123}I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy in predicting the effectiveness of {beta}-blocker therapy in dilated cardiomyopathy (DCM) was investigated from the standpoint of long-term prognosis. The subjects were 53 DCM patients in whom {beta}-blockers had been successfully introduced and used for 6 months or longer. When symptoms were stable before the introduction of {beta}-blockers and for up to 1 year thereafter, MIBG myocardial single-photon emission computed tomography was performed and the images analysed to obtain the extent score (EXT), severity score (SEV) and washout rate (WR). At the same time, echocardiography was performed to measure left ventricular ejection fraction (LVEF). Thereafter, patients were placed under observation for an average of 1,314{+-}986 days, with the occurrence of cardiac events as the endpoint. The degree of improvement in WR after introduction of {beta}-blockers was a significant predictor of cardiac events. In fact, none of the patients whose improvement in WR was valued at 10 or higher had cardiac events. Accordingly, using improvement in WR of 10 as the cut-off value, the patients were divided into two groups, ''improved'' and ''unimproved''. There were significant differences between the groups in respect of early EXT, early SEV and WR before the introduction of {beta}-blockers. As regards predictors of WR improvement, multivariate logistic regression analysis demonstrated that early EXT, WR and LVEF were significant predictors. This study shows that, from the standpoint of long-term prognosis, DCM patients who would benefit the most from {beta}-blocker therapy are those with low early EXT and early SEV and high WR before {beta}-blocker introduction regardless of LVEF values. (orig.)

  15. Use of I-123 MIBG cardiac scintigraphy to assess the impact of carvedilol on cardiac adrenergic neuronal function in childhood dilated cardiomyopathy

    International Nuclear Information System (INIS)

    Maunoury, C.; Acar, P.; Sidi, D.

    2006-01-01

    I-123 MIBG cardiac scintigraphy is a useful tool to assess cardiac adrenergic neuronal function, which is impaired in children with dilated cardiomyopathy (DCM). In adults with DCM, long-term treatment with carvedilol improves both cardiac adrenergic neuronal function and left ventricular function. The aim of this prospective study was to evaluate the impact of carvedilol on cardiac adrenergic neuronal function and on left ventricular function in seventeen patients (11 female, 6 male, mean age 39 ± 57 months, range 1 - 168 months) with DCM. All patients underwent I-123 MIBG cardiac scintigraphy and equilibrium radio-nuclide angiography before and after a 6 month period of carvedilol therapy. A static anterior view of the chest was acquired 4 hours after intravenous injection of 20 to 75 MBq of I-123 MIBG. Cardiac neuronal uptake of I-123 MIBG was measured using the heart to mediastinum count ratio (HMR). Radionuclide left ventricular ejection fraction (LVEF) was assessed following a standard protocol. There was no major cardiac events (death or transplantation) during the follow-up period. I-123 MIBG cardiac uptake and left ventricular function respectively increased by 38% and 65% after 6 months of treatment with carvedilol (HMR 223 ± 49% vs 162 ± 26%, p < 0.0001 and LVEF = 43 ± 17% vs 26 ± 11%, p < 0.0001). Carvedilol can improve cardiac adrenergic neuronal function and left ventricular function in children with DCM. Further studies are needed to assess the relationship between improvement in I-123 MIBG cardiac uptake and the beneficial effects of carvedilol on morbidity and mortality. (authors)

  16. Phaeochromocytoma and functioning paraganglioma in childhood and adolescence: Role of iodine 131 metaiodobenzylguanidine

    International Nuclear Information System (INIS)

    Khafagi, F.A.; Shapiro, B.; Fischer, M.; Sisson, J.C.; Beierwaltes, W.H.; Hutchinson, R.

    1991-01-01

    Phaeochromocytomas and functioning paragangliomas are rare tumours in childhood and adolescence. We review our experience of 43 cases (24 men, 19 women) who were first diagnosed at the age of ≤ 18 years. All patients were evaluated at some point in their illness, with iodine 131 metaiodobenzylguanidine ( 131 I-mIBG) scintigraphy. Eight patients (19%) had bilateral adrenal tumours, 12 (28%) had solitary extraadrenal tumours, and 8 (19%) had multiple tumours. In 10 patients (23%), the tumours were associated with a familial neurocristopathic syndrome. Thirteen of 24 (54%) unifocal tumours which were initially considered to be benign ultimately proved to be multi-focal and/or malignant. The final prevalence of malignancy was 60% - 26 patients, of whom only 15 (57%) had obviously malignant tumours at the time of diagnosis. Primary tumour size ≥ 5 cm was more commonly associated with a malignant course in adrenal but not extra-adrenal tumours. No other clinical, biochemical or morphological characteristic was significantly associated with malignancy. Although the high prevalence of malignancy in this series at least partly reflects referral bias, the need for lifelong follow-up of these patients is underscored. 131 I-mIBG scintigraphy was positive in 36 patients (84%), with a somewhat lower false-negative rate (12%) than X-ray computed tomography (20%). Eight patients with malignant tumours received therapeutic doses of 131 I-mIBG, with partial tumour responses in 3. Thus, 131 I-mIBG is an efficacious, non-invasive, localising agent and may be considered as a palliative therapeutic agent when alternatives have failed. (orig.)

  17. Assessment of inferior wall in 123I-metaiodobenzylguanidine myocardial SPECT in diabetic patients

    International Nuclear Information System (INIS)

    Fukumoto, Yoshihiro; Kuroda, Yasuhisa; Ohta, Jun; Osono, Ken; Saitou, Miyoko; Suzuki, Mituaki; Nakajima, Toshiki

    1994-01-01

    A phantom experiment and a clinical assessment have been made with the purpose of investigating the causes of low accumulation and deficiency of the inferior wall in 123 I-metaiodobenzylguanidine (MIBG) myocardial SPECT and the method for its evaluation. By the phantom experiment, assessments were made regarding (1) influence of the liver positioned adjacently; and (2) involvement of absorption and attenuation of the inferior wall. For the clinical assessment, 84 patients with diabetes in whom no abnormality was observed by exercise myocardial SPECT ( 201 TlCl) and 5 cases of inferior myocardial infarction (OMI group) were adopted as subjects. The inferior walls were evaluated as visually deficient because of the adjacently-positioned liver, but no low value was exhibited by quantitative evaluation. By pulmonary mediastinal phantom (-), improvement of the inferior wall was observed visually and quantitatively, compared with pulmonary mediastinal phantom (+). By quantitative evaluation, the patients were classified into normal MIBG group (N group); segmentally deficient group (S group); and non-accumulated group (DH group). In addition, S group was classified by severity score into those from S 1 to S 4 groups. No significant difference was observed in Relative Regional Uptake (RRU) in the inferior wall between S 4 group and OMI group. To sum up, we considered the causes for low accumulation and deficiency of the inferior wall, (1) adjacently-positioned liver; (2) absorption and attenuation; and (3) the lesion itself. Visual evaluation is not sufficient as the evaluating method. Quantitative evaluation becomes necessary. (author)

  18. Biodistribution and dosimetry of iodine-123-labelled Z-MIVE: an oestrogen receptor radioligand for breast cancer imaging

    NARCIS (Netherlands)

    Rijks, L. J.; Busemann Sokole, E.; Stabin, M. G.; de Bruin, K.; Janssen, A. G.; van Royen, E. A.

    1998-01-01

    This study reports on the distribution and radiation dosimetry of iodine-123-labelled cis-11beta-methoxy-17alpha-iodovinyloestradiol (Z-[123I]MIVE), a promising radioligand for imaging of oestrogen receptors (ERs) in human breast cancer. Whole-body scans were performed up to 24 h after intravenous

  19. Diagnostic accuracy of apparent diffusion coefficient and 123I-metaiodobenzylguanidine for differentiation of multiple system atrophy and Parkinson's disease.

    Directory of Open Access Journals (Sweden)

    Atsushi Umemura

    Full Text Available BACKGROUND: It is often hard to differentiate Parkinson's disease (PD and parkinsonian variant of multiple system atrophy (MSA-P, especially in the early stages. Cardiac sympathetic denervation and putaminal rarefaction are specific findings for PD and MSA-P, respectively. PURPOSE: We investigated diagnostic accuracy of putaminal apparent diffusion coefficient (ADC test for MSA-P and (123I-metaiodobenzylguanidine (MIBG scintigram for PD, especially in early-stage patients. METHODS: The referral standard diagnosis of PD and MSA-P were the diagnostic criteria of the United Kingdom Parkinson's Disease Society Brain Bank Criteria and the second consensus criteria, respectively. Based on the referral standard criteria, diagnostic accuracy [area under the receiver-operator characteristic curve (AUC, sensitivity and specificity] of the ADC and MIBG tests was estimated retrospectively. Diagnostic accuracy of these tests performed within 3 years of symptom onset was also investigated. RESULTS: ADC and MIBG tests were performed on 138 patients (20 MSA and 118 PD. AUC was 0.95 and 0.83 for the ADC and MIBG tests, respectively. Sensitivity and specificity were 85.0% and 89.0% for MSA-P diagnosis by ADC test and 67.0% and 80.0% for PD diagnosis by MIBG test. When these tests were restricted to patients with disease duration ≤ 3 years, the sensitivity and specificity were 75.0% and 91.4% for the ADC test (MSA-P diagnosis and 47.7% and 92.3% for the MIBG test (PD diagnosis. CONCLUSIONS: Both tests were useful in differentiating between PD and MSA-P, even in the early stages. In early-stage patients, elevated putaminal ADC was a diagnostic marker for MSA-P. Despite high specificity of the MIBG test, careful neurological history and examinations were required for PD diagnosis because of possible false-negative results.

  20. Diagnostic accuracy of apparent diffusion coefficient and 123I-metaiodobenzylguanidine for differentiation of multiple system atrophy and Parkinson's disease.

    Science.gov (United States)

    Umemura, Atsushi; Oeda, Tomoko; Hayashi, Ryutaro; Tomita, Satoshi; Kohsaka, Masayuki; Yamamoto, Kenji; Sawada, Hideyuki

    2013-01-01

    It is often hard to differentiate Parkinson's disease (PD) and parkinsonian variant of multiple system atrophy (MSA-P), especially in the early stages. Cardiac sympathetic denervation and putaminal rarefaction are specific findings for PD and MSA-P, respectively. We investigated diagnostic accuracy of putaminal apparent diffusion coefficient (ADC) test for MSA-P and (123)I-metaiodobenzylguanidine (MIBG) scintigram for PD, especially in early-stage patients. The referral standard diagnosis of PD and MSA-P were the diagnostic criteria of the United Kingdom Parkinson's Disease Society Brain Bank Criteria and the second consensus criteria, respectively. Based on the referral standard criteria, diagnostic accuracy [area under the receiver-operator characteristic curve (AUC), sensitivity and specificity] of the ADC and MIBG tests was estimated retrospectively. Diagnostic accuracy of these tests performed within 3 years of symptom onset was also investigated. ADC and MIBG tests were performed on 138 patients (20 MSA and 118 PD). AUC was 0.95 and 0.83 for the ADC and MIBG tests, respectively. Sensitivity and specificity were 85.0% and 89.0% for MSA-P diagnosis by ADC test and 67.0% and 80.0% for PD diagnosis by MIBG test. When these tests were restricted to patients with disease duration ≤ 3 years, the sensitivity and specificity were 75.0% and 91.4% for the ADC test (MSA-P diagnosis) and 47.7% and 92.3% for the MIBG test (PD diagnosis). Both tests were useful in differentiating between PD and MSA-P, even in the early stages. In early-stage patients, elevated putaminal ADC was a diagnostic marker for MSA-P. Despite high specificity of the MIBG test, careful neurological history and examinations were required for PD diagnosis because of possible false-negative results.

  1. Renal excretion of iodine-131 labelled meta-iodobenzylguanidine and metabolites after therapeutic doses in patients suffering from different neural crest-derived tumours

    International Nuclear Information System (INIS)

    Wafelman, A.R.; Hoefnagel, C.A.; Maessen, H.J.M.; Maes, R.A.A.; Beijnen, J.H.

    1997-01-01

    Iodine-131 labelled meta-iodobenzylguanidine ([ 131 I[MIBG) is used for diagnostic scintigraphy and radionuclide therapy of neural crest-derived tumours. After administration of therapeutic doses of [ 131 I[MIBG (3.1-7.5 GBq) to 17 patients (n=32 courses), aged 2-73 years, 56%±10%, 73%±11%, 80%±10% and 83%±10% of the dose was cumulatively excreted as total radioactivity in urine at t=24 h, 48 h, 72 h and 96 h, respectively. Except for two adult patients, who showed excretion of 14%-18% of [ 131 I[meta-iodohippuric acid ([ 131 I[MIHA), the cumulatively excreted radioactivity consisted of >85% [ 131 I[MIBG, with 6% of the dose excreted as free [ 131 I[iodide, 4% as [ 131 I[MIHA and 2.5% as an unknown iodine-131 labelled metabolite. Cumulative renal excretion rates of total radioactivity and of [ 131 I[MIBG appeared to be higher in neuroblastoma and phaeochromocytoma patients than in carcinoid patients. Based on the excretion of small amounts of [ 131 I[meta-iodobenzoic acid in two patients, a possible metabolic pathway for [ 131 I[MIBG is suggested. The degree of metabolism was not related to the extent of liver uptake of radioactivity. (orig.). With 2 figs., 5 tabs

  2. Accumulation of iodine-123 in thyroid and urinary excretion of iodine in an area of endemic goiter

    Energy Technology Data Exchange (ETDEWEB)

    Goebel, R; Leb, G; Passath, A; Knapp, G

    1983-06-20

    The thyroid radioiodine uptakes decreased from 52.4% (1982, 24-hours, /sup 131/I) to 30.5% (1981, /sup 123/I). The severity of scintigraphic findings decreased as well, although the incidence of nodules remains definitely high. The excretion of iodine was found to be 53.28 ..mu..g/g creatine and is low compared with the present uptakes. It characterizes an area of endemic goitre degree I, borderline to degree II.

  3. Iodine-123 miniplasmin for the detection of deep venous thrombosis

    International Nuclear Information System (INIS)

    Schubiger, P.A.; Haeberli, A.; Gallino, A.; Straub, P.W.

    1989-09-01

    Human plasminogen (MW 90'000) is cleaved by elastase into several fragments, including one with a molecular weight of 38'000 (mini-plasminogen). This fragment retains sufficiently preserved fibrin binding sites but lacks the affinity for α 2 -antiplasmin. Therefore radiolabelled miniplasmin was tested in 21 patients with suspected deep venous thrombosis, in 5 patients with lymphedema and in 5 healthy controls for its potential use as fast marker of deep venous thrombosis. 250 μCi of Iodine-123 miniplasmin was given i.v. after previous activation with 3000 IU urokinase. The tracer distribution was measured 15, 30 and 60 minutes after injection at 10 points over each leg. The mean left/right ratio obtained in the 5 volunteers was 1.04 (range 0.89-1.12). In the patients the test was considered positive when the left/right ratio was greater than 1.15 or smaller than 0.85 at two adjacent locations and in two consecutive measuring times. In the 21 patients studied both tests gave concurrent results in 19, while in one patient with a positive and in one patient with a negative phlebography the miniplasmintest gave opposite results. In 4 of the 5 patients with edema and no thrombosis the miniplasmintest was negative. Most positive tests were conclusive as early as 15 minutes after injection of miniplasmin. The sensitivity was calculated to be 90% and the specificity 85%. Therefore Iodine-123 miniplasmin has been estimated as a fast, non invasive marker for the diagnosis of deep venous thrombosis and preliminary clinical studies with scintigraphy have been performed on over 50 patients. Evaluation gave a sensitivity between 40% and 86% and a specificity between 62% and 100%. Clinical studies have not been continued. Since I-123 miniplasmin is not available around the clock, it can't be used in emergency diagnosis. (author) 2 figs., 5 tabs., 30 refs

  4. Evaluation of cardiac adrenergic neuronal damage in rats with doxorubicin-induced cardiomyopathy using iodine-131 MIBG autoradiography and PGP 9.5 immunohistochemistry

    International Nuclear Information System (INIS)

    Jeon, T.J.; Lee, J.D.; Ha, J.-W.; Yang, W.I.; Cho, S.H.

    2000-01-01

    Doxorubicin is one of the most useful anticancer agents, but its repeated administration can induce irreversible cardiomyopathy as a major complication. The purpose of this study was to investigate doxorubicin toxicity on cardiac sympathetic neurons using iodine-131-metaiodobenzylguanidine (MIBG) and protein gene product (PGP) 9.5 immunohistochemistry, which is a marker of cardiac innervation. Wistar rats were treated with doxorubicin (2 mg/kg, i.v.) once a week for 4 (n=5), 6 (n=6) or 8 (n=7) weeks consecutively. Left ventricular ejection fraction (LVEF), calculated by M-mode echocardiography, was used as an indicator of cardiac function. Plasma noradrenaline (NA) concentration was measured by high-performance liquid chromatography (HPLC). 131 I-MIBG uptake of the left ventricular wall (24 ROIs) was measured by autoradiography. 131 I-MIBG uptake pattern was compared with histopathological results, the neuronal population on PGP 9.5 immunohistochemistry and the degree of myocyte damage assessed using a visual scoring system on haematoxylin and eosin and Masson's trichrome staining. LVEF was significantly decreased in the 8-week group (P 131 I-MIBG uptake ratio of subepicardium to subendocardium were significantly increased (P<0.05) in the 8-week group as compared with the control group. It may be concluded that radioiodinated MIBG is a reliable marker for the detection of cardiac adrenergic neuronal damage in doxorubicin-induced cardiomyopathy; it detects such damage earlier than do other clinical parameters and in this study showed a good correlation with the reduction in the neuronal population on PGP 9.5 stain. The subendocardial layer appeared to be more vulnerable to doxorubicin than the subepicardium. (orig.)

  5. Production of iodine-123 radiobiological specimen on 25 MeV electron beam

    International Nuclear Information System (INIS)

    Oganesyan, Yu.Ts.; Starodub, G.Ya.; Buklanov, G.V.; Korotkin, Yu.S.; Belov, A.G.

    1988-01-01

    The technique is described and experimental results are presented for production of radioactive specimen-iodine-123 for medical biological investigations. It is shown that in ten hour irradiation of 124 Xe enriched target of 10 g weight by the 25 MeV electron beam at MT-25 microtron short lived 123 I with activity of about 200 mCl can be accumulated. The procedure was developed for extraction of radioactive atoms and preparing the solution that permits to obtain during 1-1.5 h after the end of irradiation the specimen which satisfies all pharmacopeia requirements. It follows from the results that using small-size electron accelerators with the beam energy up to 25 MeV permits to organize economical and large-scale production of high quality radioactive specimen of 123 I for servicing a large region of this country. 14 refs.; 4 figs.; 1 tab

  6. Human pancreas scintigraphy using iodine-123-labeled HIPDM and SPECT

    International Nuclear Information System (INIS)

    Yamamoto, K.; Shibata, T.; Saji, H.; Kubo, S.; Aoki, E.; Fujita, T.; Yonekura, Y.; Konishi, J.; Yokoyama, A.

    1990-01-01

    The pancreatic affinity of iodine-123-labeled HIPDM (N,N,N'-trimethyl-N'-(2-hydroxy-3-methyl-5-iodobenzyl)-1,3-propane diamine) ([ 123 I]HIPDM) was studied in 18 cases (5 normal volunteers, 7 cases with pancreas cancer, and 6 with chronic pancreatitis). In the normal cases, the pancreas was visualized in the planar images as early as 3 hr, and again at 20 hr postinjection. Single-photon emission computed tomography (SPECT) performed following 3-hr planar scintigraphy, provided excellent pancreas images without an overlap of activity in the liver or spleen. The mean pancreas-to-liver (P/L) ratio was 1.26 +/- 0.22 in normal controls. With the exception of one case of massive calcification in the pancreas, the entire pancreas could be observed in the cases with chronic pancreatitis, but the P/L ratio was 0.74 +/- 0.15, significantly lower than that of normal cases. Defective areas of the distal portion of the pancreas were clearly seen in those with cancer of the pancreas. The results of our study indicate that [ 123 I] HIPDM may have clinical potential as a human pancreas imaging agent

  7. Iodine-123-iodobenzamide imaging, MRI and apomorphine testing in the evaluation of patients with Parkinsonism

    International Nuclear Information System (INIS)

    Van der Schaaf, A.A.; Stell, R.; Groom, G.N.; Lambrecht, R.; Najdovski, L.; Cardaci, G.; Davis, S.; Dikic, B.; Laing, B.; Mastaaglia, F.L.; O''Brein, J.

    1998-01-01

    Full text: Idiopathic Parkinson''s disease (IPD) is characterised by a loss of dopaminergic neurons in the substantia nigra. Other neurodegenerative disorders may mimic IPD, and the clinical distinction is important in patient management. Iodine-123-iodobenzamide (IBZM) has high specific binding to dopamine-2 (D2) receptors enabling SPECT studies of these receptors in the human brain. A significant reduction of D2 receptor binding of 123 I-lBZM has been shown in the basal ganglia of patients with Parkinsonian syndromes (PS) but normal uptake is seen in patients with IPD. Iodine-123-lBZM SPECT imaging has been proposed as a means of distinguishing between patients with IPD and PS and may be of value in predicting the long-term responsiveness to dopaminergic drugs. Magnetic resonance imaging has also been used to distinguish IPD from PS, and apomorphine testing is in use as a clinical means of predicting response to dopaminergic drugs. We plan to evaluate the sensitivity and specificity of 123 I-lBZM SPECT, MRI and apomorphine testing for categorisation of patients and the prediction of responsiveness to dopaminergic drugs. To date we have studied 17 patients. SPECT imaging of the brain was carried out two hours after the i.v. administration of 185 MBq of 123 I-lBZM and visual and semi-quantitative analysis, using ratios of uptake in basal ganglia to frontal cortex, occipital cortex and cerebellum have been carried out. Although the data are incomplete, preliminary results suggest that there is a poor correlation of 123 I-lBZM uptake with the provisional clinical diagnosis and with apomorphine testing, but that 123 I-lBZM uptake is a predictor of dopaminergic response

  8. Determination of the survival rate in patients with congestive heart failure stratified by 123I-MIBG imaging. A meta-analysis from the studies performed in Japan

    International Nuclear Information System (INIS)

    Kuwabara, Yoichi; Tamaki, Nagara; Nakata, Tomoaki; Yamashina, Shohei; Yamazaki, Junichi

    2011-01-01

    The goals of this meta-analysis were to determine survival rates in patients with heart failure (HF) assessed by 123 I-metaiodobenzylguanidine (MIBG) imaging results using recently published studies and to determine the prognostic value of 123 I-MIBG imaging. We reviewed published cohort studies carried out in Japan that compared the prognosis of patients with their 123 I-MIBG activity quantified as late heart-to-mediastinum ratio (H/M) or washout rate by performing a PubMed search for articles in English up to December 2006. Studies were selected if they analyzed a clearly defined lethal outcome (cardiovascular death) using life tables to estimate the odds ratio at 24 months after enrollment. Of 158 articles related to cardiac 123 I-MIBG, seven referred to studies that met the inclusion criteria: 5 evaluated H/M via 123 I-MIBG in a total of 866 patients and 4 calculated washout rate in a total of 491 patients. A low H/M indicated a high risk of cardiac death: pooled odds ratio, 5.2; 95% confidence interval (CI) of 3.1-5.7. A high washout was also associated with lethal events with a pooled odds ratio of 2.8 (CI: 1.6-5.0). The association between washout and cardiac death was heterogeneous (Chi-square=11.0, P 123 I-MIBG studies conducted in Japan indicated that both a decreased cardiac 123 I-MIBG activity (H/M) and an increased washout rate are indicative of a poor prognosis in patients with chronic heart failure. (author)

  9. Thyroid uptake and imaging with iodine-123 at 4-5 hours: replacement of the 24-hour iodine-131 standard

    International Nuclear Information System (INIS)

    Floyd, J.L.; Rosen, P.R.; Borchert, R.D.; Jackson, D.E.; Weiland, F.L.

    1985-01-01

    A study was carried out to determine the suitability of utilizing a 4 to 5 hr interval from administration of Iodine-123 to imaging and uptake measurement as a replacement for the 24-hr standard originally established with Iodine-131. In 55 patients who underwent scintigraphy at 4 and 24 hr, there was no discrepancy between paired images. In 55 patients who had uptake measured at 4 and 24 hr and in 191 patients who had uptake measured at 5 and 24 hr, the early measurements proved equal or better discriminants of euthyroid from hyperthyroid patients. In our institutions, these findings and the logistical advantages of completing the exam in 4-5 hr led us to abandon the 24-hr study in the majority of patients

  10. Ageing effect on 18F-DOPA and 123I-MIBG uptake: a cross-sectional study.

    Science.gov (United States)

    Chiaravalloti, Agostino; Barbagallo, Gaetano; Ricci, Maria; Sannino, Pasqualina; Karalis, Georgios; Ursini, Francesco; Schillaci, Orazio

    2018-06-01

    The aim of this study was to investigate the relationship between age and uptake of fluorine-18-L-dihydroxyphenylalanine (F-DOPA) in the brain and myocardial uptake of iodine-123-metaiodobenzylguanidine (I-MIBG) in normal adult participants. To this end, a total of 72 healthy participants were enroled. Of these, 37 individuals (male, 21; female, 16; mean age: 60±12 years; age range: 38-85 years) underwent F-DOPA PET/CT, whereas 35 individuals (male, 19; female, 16; mean age: 61±17 years; age range: 17-87 years) underwent I-MIBG scintigraphy. For F-DOPA PET/CT, regions of interest were placed on the caudate nucleus, globus pallidus and putamen by means of the WFU Pickatlas tool implemented in SPM8 and further analysed after a normalization process. For I-MIBG scintigraphy, regions of interest were set over the upper mediastinum and a heart-to-mediastinum count ratio was calculated. The relation between age and normalized F-DOPA values or heart-to-mediastinum ratio values was examined using correlation analysis of variance and Pearson's correlation coefficient. We did not find any significant relationship between age and F-DOPA and I-MIBG uptake, respectively. Our findings suggest that both brain F-DOPA PET/CT and cardiac I-MIBG scintigraphy represent age-independent biomarkers whose analyses of quantitative uptake may not require adjustment for patients' age.

  11. Research and clinical applications of iodine-123 fibrinogen in coagulation disorders

    International Nuclear Information System (INIS)

    DeNardo, G.L.; DeNardo, S.J.; Swanson, M.A.; Wortman, J.A.; Twardock, A.R.; Colcher, D.

    1985-01-01

    A great many proteins are available to serve as molecular substrates suitable for investigation of normal and diseased states. These proteins, labeled with the appropriate radioisotope of iodine, can be used for immunoassays, imaging, and systemic radiotherapy. The authors describe 12 years experience using coagulation proteins for the investigation of cancer, venous thrombosis, renal transplant rejection, and other coagulopathies. Scintigraphy with 123 I-fibrinogen and immunoassays for circulating antigens such as fibrinopeptide A appear to be promising diagnostic, as well as investigative, tools

  12. Iodine-123 BMIPP Scintigraphy in the Evaluation of Patients with Heart Failure

    Energy Technology Data Exchange (ETDEWEB)

    Nakae, I.; Matsuo, S.; Koh, T.; Mitsunami, K.; Horie, M. [Shiga Univ. of Medical Science, Otsu (Japan). Depts. of Cardiovascular and Respiratory Medicine, and of General Medicine

    2006-10-15

    Purpose: To investigate whether cardiac parameters obtained by I-123 15-(p-iodophenyl)-3-methyl pentadecanoic acid (BMIPP, a radioactive fatty acid analogue) myocardial scintigraphy are useful as indicators of disease severity and predictors of cardiac events in congestive heart failure (CHF). Material and Methods: Thirty-two CHF patients (functional class: 17 in NYHA II and 15 in NYHA III at the time of this study) were compared with 18 normal control subjects. Myocardial scintigraphy was performed 15 min and 3 hours after I-123 BMIPP injection. The heart-to-mediastinum count ratio of I-123 BMIPP on the initial (H/Mi) and delayed (H/Md) images and the washout rate (WR) were calculated. Results: Both H/Mi and H/Md were lower in CHF than in controls (H/Mi 1.96{+-}0.18 vs. 2.30{+-}0.29; H/Md 1.72{+-}0.15 vs. 1.97{+-}0.21; both P <0.001), but WR was higher in CHF than in controls (WR (%) 23.7{+-}5.7 vs. 18.2{+-}6.0, P <0.01). Both H/Mi (R = 0.42, P <0.05) and H/Md (R = 0.45, P <0.05) correlated positively with the left ventricular (LV) ejection fraction (EF), estimated by echocardiography. The WR correlated positively with the plasma B-type natriuretic peptide (BNP) level (R = 0.47, P <0.01). Kaplan-Meier analysis showed an earlier CHF progression for patients with a lower H/Mi (<1.94). Conclusion: Myocardial metabolic abnormality evaluated by I-123 BMIPP scintigraphy is related to the severity of CHF. Furthermore, it may be useful as a predictor for cardiac events.

  13. Use of iodine-123 metaiodobenzylguanidine myocardial imaging to predict the effectiveness of β-blocker therapy in patients with dilated cardiomyopathy

    International Nuclear Information System (INIS)

    Fukuoka, Shuji; Hayashida, Kohei; Hirose, Yoshiaki; Shimotsu, Yoriko; Ishida, Yoshio; Kakuchi, Hiroyuki; Eto, Tanenao

    1997-01-01

    We studied 13 patients with dilated cardiomyopathy (DCM) and seven normal subjects. We obtained myocardial SPET images 15 min and 4 h after administration of 123 I-MIBG (111 MBq). Studies were performed in the patients with DCM before and 1 and 3 months after the administration of metoprolol and in the normal subjects. We calculated the regional 123 I-MIBG washout rate (r-WR) in the SPET image, and the global 123 I-MIBG washout rate (g-WR) and heart-mediastinum activity ratio (H/M) using the anterior planar image. We classified patients into those showing a ≥5% increase in LV ejection fraction (LVEF) at 3 months compared with LVEF values before the treatment (group I, n=7) and those showing a 123 I-MIBG SPET imaging can be used to predict the functional improvement of LVEF at 1 month of β-blocker therapy in patients with DCM. (orig./VHE). With 4 figs., 1 tab

  14. Iodine-123 scintigraphy in the evaluation of pediatric thyroid disorders: a ten year experience

    International Nuclear Information System (INIS)

    Paltiel, H.J.; Summerville, D.A.; Treves, S.T.

    1992-01-01

    Between 1978 and 1987, we studied 280 children with iodine-123 ( 123 I) scintigraphy. Indications for scintigraphy included hypothyroidism, neck masses, hyperthyroidism, and miscellaneous reasons. Scintigraphy was helpful in distinguishing anatomic from functional causes of hyothyroidism. It reliably identified the location of the thyroid gland in patients with neck masses. The functional status of thyroid nodules was readily assessed and was important in directing further treatment. Scintigraphy added little to the management of children with post-irradiation hypothyroidism without a palpable nodule, patients with Hashimoto thyroiditis or Graves disease when the clinical diagnosis was straightforward. (orig./GDG)

  15. Iodine-123 scintigraphy in the evaluation of pediatric thyroid disorders: a ten year experience

    Energy Technology Data Exchange (ETDEWEB)

    Paltiel, H.J.; Summerville, D.A.; Treves, S.T. (Children' s Hospital, Boston, MA (United States). Div. of Nuclear Medicine Harvard Medical School, Boston, MA (United States))

    1992-08-01

    Between 1978 and 1987, we studied 280 children with iodine-123 ([sup 123]I) scintigraphy. Indications for scintigraphy included hypothyroidism, neck masses, hyperthyroidism, and miscellaneous reasons. Scintigraphy was helpful in distinguishing anatomic from functional causes of hyothyroidism. It reliably identified the location of the thyroid gland in patients with neck masses. The functional status of thyroid nodules was readily assessed and was important in directing further treatment. Scintigraphy added little to the management of children with post-irradiation hypothyroidism without a palpable nodule, patients with Hashimoto thyroiditis or Graves disease when the clinical diagnosis was straightforward. (orig./GDG).

  16. Functional imaging in phaeochromocytoma and neuroblastoma with {sup 68}Ga-DOTA-Tyr{sup 3}-octreotide positron emission tomography and {sup 123}I-metaiodobenzylguanidine

    Energy Technology Data Exchange (ETDEWEB)

    Kroiss, Alexander; Putzer, Daniel; Uprimny, Christian; Decristoforo, Clemens; Gabriel, Michael; Warwitz, Boris; Waitz, Dietmar; Kendler, Dorota; Virgolini, Irene Johanna [Innsbruck Medical University, Department of Nuclear Medicine, Innsbruck (Austria); Santner, Wolfram; Kranewitter, Christof [Innsbruck Medical University, Department of Radiology, Innsbruck (Austria)

    2011-05-15

    {sup 68}Ga-DOTA-Tyr{sup 3}-octreotide positron emission tomography ({sup 68}Ga-DOTA-TOC PET) has proven to be superior to {sup 111}In-DTPA-D-Phe{sup 1}-octreotide ({sup 111}In-octreotide) planar scintigraphy and SPECT imaging in neuroendocrine tumours (NETs). Because of these promising results, we compared the accuracy of {sup 123}I-metaiodobenzylguanidine ({sup 123}I-MIBG) imaging with PET in the diagnosis and staging of metastatic phaeochromocytoma and neuroblastoma, referring to radiological imaging as reference standard. Three male and eight female patients (age range 3 to 68 years) with biochemically and histologically proven disease were included in this study. Three male and three female patients were suffering from phaeochromocytoma, and five female patients from neuroblastoma. Comparative evaluation included morphological imaging with CT or MRI, functional imaging with {sup 68}Ga-DOTA-TOC PET and {sup 123}I-MIBG imaging. Imaging results were analysed on a per-patient and on a per-lesion basis. On a per-patient basis, both {sup 68}Ga-DOTA-TOC and {sup 123}I-MIBG showed a sensitivity of 100%, when compared with anatomical imaging. In phaeochromocytoma patients, on a per-lesion basis, the sensitivity of {sup 68}Ga-DOTA-TOC was 91.7% and that of {sup 123}I-MIBG was 63.3%. In neuroblastoma patients, on a per-lesion basis, the sensitivity of {sup 68}Ga-DOTA-TOC was 97.2% and that of {sup 123}I-MIBG was 90.7%. Overall, in this patient cohort, {sup 68}Ga-DOTA-TOC PET identified 257 lesions, anatomical imaging identified 216 lesions, and {sup 123}I-MIBG identified only 184 lesions. In this patient group, the overall sensitivity of {sup 68}Ga-DOTA-TOC PET on a lesion basis was 94.4% (McNemar p<0.0001) and that of {sup 123}I-MIBG was 76.9% (McNemar p<0.0001). Our analysis in this relatively small patient cohort indicates that {sup 68}Ga-DOTA-TOC PET may be superior to {sup 123}I-MIBG gamma-scintigraphy and even to the reference CT/MRI technique in providing

  17. Clinical application of cardiac SPECT

    International Nuclear Information System (INIS)

    Nishimura, Shigeyuki

    1999-01-01

    Single-photon emission computed tomography (SPECT) has replaced planar imaging techniques for myocardial scintigraphy. Thallium-201 was the dominant agent employed for myocardial perfusion imaging. Today new technetium-99m labelled radionuclides have been used as excellent alternatives to 201 Tl for detection of coronary artery disease, prognostification, and even assessment of myocardial viability. Pharmacologic stress imaging using either dipyridamole, adenosine or dobutamine is a substitute for exercise stress. Accurate determination of myocardial viability is vitally important for clinical decision making for patients with LV dysfunction who will most benefit from revascularization. Stunned and hibernated myocardium may result in profound regional LTV dysfunction in absence of necrosis. The various approach such as stress-redistribution-reinjection imaging, rest-redistribution imaging and stress-redistribution-24 hours delayed imaging has been utilized to assess myocardial viability with 201 Tl. Quantitative assessment of 99m Tc MIBI uptake reflect the degree of viability. 123 I-Metaiodobenzylguanidine (MIBG), an analog of norepinephrine, has been used for scintigraphic assessment of regional cardiac adrenergic innervation. Cardiac sympathetic denervation, assessed by 123 I-MIBG, due to ischemia in non-Q myocardial infarction and unstable angina has been shown. Quantitative cardiac MIBG scintigram was shown to have prognostic value in patients with severe congestive heart failure. 23 I-BMIPP (ρ-methyl-iodophenyl pentadecanoic acid) has been used to assess myocardial fatty acid utilization. BMIPP has the memory function of ischemia in unstable angina, since decreased BMIPP uptake persists several days after ischemic episode. Nuclear cardiology in Japan has experienced an expansion in the techniques including use of new radionuclides, 99m Tc perfusion agents, 123 I-MIBG and 23 I-BMIPP and in associated clinical application to the various cardiac diseases

  18. Iodine-123 labelled nor-beta-CIT binds to the serotonin transporter in vivo as assessed by biodistribution studies in rats

    NARCIS (Netherlands)

    Booij, J.; Knol, R. J.; Reneman, L.; de Bruin, K.; Janssen, A. G.; van Royen, E. A.

    1998-01-01

    Iodine-123 labelled 2beta-carbomethoxy-3beta-4-iodophenylnortropane (nor-beta-CIT), a radioiodinated cocaine analogue, was evaluated as an agent for the in vivo labelling of serotonin transporters by biodistribution studies in rats. Intravenous injection of [123I]nor-beta-CIT resulted in high

  19. Estimation of regional myocardial sympathetic neuronal function with I-123 metaiodobenzylguanidine (MIBG) myocardial images in patients with cardiomyopathy

    International Nuclear Information System (INIS)

    Tanaka, Takeshi; Aizawa, Tadanori; Kato, Kazuzo; Nakano, Hajime; Igarashi, Masaki; Ueno, Takashi; Hirosawa, Koshichiro; Kusakabe, Kiyoko.

    1989-01-01

    Myocardial SPECT images with I-123 metaiodobenzylguanidine (MIBG) were obtained in 10 patients with cardiomyopathy under stable state. For myocardial imaging, MIBG and Tl-201 (Tl) were simultaneously injected and collected. The ratio of MIBG to Tl (M/T ratio) in ROI was obtained with 50% cut off levels in order to eliminate background activity. The patients were divided into three major groups: (l) those who had the M/T ratio ranging from 0.8 to l.20 at rest and had marked defects in the infero-lateral region on delayed MIBG images, where pathophysiologically accelerated regional sympathetic neuronal function was suspected (n=5), (II) those who had increased M/T ratios (l.6 and l.7) in the basal septal wall (n=3), and (III) those who had decreased M/T ratios (0.7 and 0.75) in the apical septal wall, where depletion of myocardial norepinephrine was suspected (n=2). These findings indicate the potential of myocardial MIBG images to evaluate myocardial distribution of norepinephrine, i.e. myocardial sympathetic neuronal function. Certain shortcomings, such as an increased background due to dual isotopes and an increased pulmonary uptake of MIBG, require further study on quantitative methods. (Namekawa, K)

  20. Utility of thallium-201 and iodine-123 metaiodobenzylguanidine in the scintigraphic detection of neuroendocrine neoplasia

    International Nuclear Information System (INIS)

    Montravers, F.; Coutris, G.; Sarda, L.; Mensch, B.; Talbot, J.N.

    1993-01-01

    In order to determine whether the association of the two markers is able to improve the detection of neuroendocrine lesions, 137 sctinigraphic examinations using MIBG and thallium were performed in 101 patients referred for suspicion or follow-up of neuroendocrine tumours. Thallium chloride was first injected (1 MBq/kg), images being acquired about 20 min after injection; 123 I-MIBG (4 MBq/kg) was then injected and images acquired 5 and 24 h later. In patients with phaeochromocytoma or neuroblastoma, thallium scintigraphy appeared of little help since no tumoural site was discovered by thallium accumulation alone. In contrast, thallium examination seemed of interest in the detection of paraganglioma and MTC, the association of the two radiopharmaceuticals increasing the number of detected sites. (orig./MTG)

  1. Iodine-123 ortho-iodohippurate: some experiences with logistics and quality control

    International Nuclear Information System (INIS)

    Lathrop, K.A.; Harper, P.V.

    1985-01-01

    Three years ago, in response to a request for proposal, a one-year contract was awarded to the University of Chicago by the Bureau of Radiological Health (BRH) to measure accurately the organ distribution of Hippuran in 30 human subjects in order to refine the radiation absorbed dose estimates. The decision had been made to use quantitative imaging methods with iodine-123 as a label to achieve good uptake data, with low radiation dose to the subjects. The problems encountered in obtaining good quality material for the study are discussed

  2. The results of questionnaire on quantitative assessment of 123I-metaiodobenzylguanidine myocardial scintigraphy in heart failure

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Sugishita, Yasurou; Sasaki, Yasuhito.

    1997-01-01

    This study was done by working group under the cooperation between Japanese Society of Nuclear Medicine and Japanese Circulation Society. We evaluated the usefulness of quantitative assessment of 123 I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy in heart failure by the results of questionnaire. Forty-nine (72.1%) of 68 selected institutions participated in this study. The incidence of MIBG myocardial scintigraphy used in heart failure was 41.1%. The imaging protocol was mostly done by both planar and SPECT at 15 min and 3.6 hr after intravenous injection of 111 MBq of MIBG. The quantitative assessment was mostly done by heart/mediastinum (H/M) ratio and washout rate analysis based on planar imaging. The mean normal value of H/M ratio were 2.34±0.36, and 2.49±0.40, at early and delayed images, respectively. The normal value of washout rate was 27.74±5.34%. On the other hand, those of H/M ratio in heart failure were 1.87±0.27, and 1.75±0.24, at early and delayed images, respectively. That of washout rate was 42.30±6.75%. These parameters were very useful for the evaluation of heart failure. In conclusion, MIBG myocardial scintigraphy was widely used for not only early detection and severity assessment, but also indication for therapy and prognosis evaluation in heart failure patients. (author)

  3. Metaiodobenzylguanidine (MIBG) uptake in Parkinson's disease also decreases at thyroid

    International Nuclear Information System (INIS)

    Matsui, Hideaki; Udaka, Fukashi; Oda, Masaya; Tamura, Akiko; Kubori, Tamotsu; Nishinaka, Kazuto; Kameyama, Masakuni

    2005-01-01

    Decreased cardiac metaiodobenzylguanidine (MIBG) uptake was reported in Parkinson's disease and this contributes to the differential diagnosis between Parkinson's disease and other forms of parkinsonism such as multiple system atrophy. However, decreased MIBG uptake of the thyroid has not been demonstrated. The objective of this study was to compare MIBG uptake of the thyroid among Parkinson's disease, multiple system atrophy and controls. Twenty-six patients with Parkinson's disease, 11 patients with multiple system atrophy and 14 controls were examined in this study. Planar images were taken 15 minutes (early images) and 3 hours (late images) after intravenous injection of 111 MBq 123 I-MIBG. MIBG uptake of the thyroid on early images decreased significantly in Parkinson's disease compared to controls (p<0.0001) and multiple system atrophy (p=0.018). MIBG uptake of the thyroid on early images decreased significantly also in multiple system atrophy compared to controls (p=0.027). On late images, thyroid uptake differed significantly only between Parkinson's disease and controls (p=0.010). Our study is the first to demonstrate decreased MIBG uptake of the thyroid in Parkinson's disease. Sympathetic nervous denervation of Parkinson's disease occurred not only in the heart but also in the thyroid. (author)

  4. Effects of cigarette smoking on iodine 123 N-isopropyl-f-iodoamphetamine clearance from the lung

    International Nuclear Information System (INIS)

    Kato, Kunihiko; Harada, Satoshi; Takahashi, Tsuneo; Katsuragawa, Shigehiko; Yanagisawa, Toru

    1991-01-01

    Iodine 123 N-isopropyl-p-iodoamphetamine ( 123 I-IMP), originally developed as a brain scanning agent, is also taken up by the lung. To evaluate the effects of cigarette smoking on the kinetics of IMP in the lung, we studied 123 I-IMP clearance from the lung in 18 volunteers (8 non-smokers and 10 smokers). After the injection of 111 MBq of 123 I-IMP into the medial cubital vein, the time-activity curve for 60 min and the regional activity using 1 frame per minute and a 64x64 matrix were obtained. The 123 I-IMP clearance curve was described as follows: C(t)=A 1 e ( -k 1 t)+A 2 e ( -k 2 t)(A 1 , A 2 : intercepts, and k 1 , k 2 : slopes of the exponential components). 123 I-IMP clearance was delayed in smokers, and k 2 was smaller in smokers. Also, a correlation between k 1 , k 2 , and the number of cigarettes smoked per day was found (r=-0.65, r=-0.74, respectively, P 123 I-IMP in the lung indicate lung metabolic disorders due to cigarette smoking. (orig.)

  5. Use of iodine-123 metaiodobenzylguanidine myocardial imaging to predict the effectiveness of {beta}-blocker therapy in patients with dilated cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Fukuoka, Shuji [Department of Radiology, National Cardiovascular Center, Osaka (Japan); Hayashida, Kohei [Department of Radiology, National Cardiovascular Center, Osaka (Japan); Hirose, Yoshiaki [Department of Radiology, National Cardiovascular Center, Osaka (Japan); Shimotsu, Yoriko [Department of Radiology, National Cardiovascular Center, Osaka (Japan); Ishida, Yoshio [Department of Radiology, National Cardiovascular Center, Osaka (Japan); Kakuchi, Hiroyuki [Department of Internal Medicine, National Cardiovascular Center, Osaka (Japan); Eto, Tanenao [First Department of Internal Medicine, Miyazaki Medical College, Miyazaki (Japan)

    1997-05-01

    We studied 13 patients with dilated cardiomyopathy (DCM) and seven normal subjects. We obtained myocardial SPET images 15 min and 4 h after administration of {sup 123}I-MIBG (111 MBq). Studies were performed in the patients with DCM before and 1 and 3 months after the administration of metoprolol and in the normal subjects. We calculated the regional {sup 123}I-MIBG washout rate (r-WR) in the SPET image, and the global {sup 123}I-MIBG washout rate (g-WR) and heart-mediastinum activity ratio (H/M) using the anterior planar image. We classified patients into those showing a {>=}5% increase in LV ejection fraction (LVEF) at 3 months compared with LVEF values before the treatment (group I, n=7) and those showing a <5% increase in LVEF (group II, n=6). In normal subjects, the r-WR values in each of the anterior, lateral, septal and inferior segments were significantly lower than those in groups I and II. These values were 18%{+-}9%, 18%{+-}15%, 20%{+-}12% and 21%{+-}15%, respectively. This study demonstrated that with regional assessment {sup 123}I-MIBG SPET imaging can be used to predict the functional improvement of LVEF at 1 month of {beta}-blocker therapy in patients with DCM. (orig./VHE). With 4 figs., 1 tab.

  6. In-111-octreotide is superior to I-123-metaiodobenzylguanidine for scintigraphic detection of head and neck paragangliomas

    NARCIS (Netherlands)

    Koopmans, Klaas Pieter; Jager, Pieter L.; Kema, Ido P.; Kersten, Michiel N.; Albers, Frans; Dullaart, Robin P. F.

    In this study, we evaluated the diagnostic yield of somatostatin receptor scintigraphy (SRS), 1-metaiodobenzylguanidine (MIBG) scintigraphy, and morphologic imaging (CT or MRI) in patients with head and neck paragangliomas. Methods: In a university hospital setting, patients considered to have head

  7. Radioiodinated tracers for myocardial imaging

    International Nuclear Information System (INIS)

    Kulkarni, P.V.; Corbett, J.R.

    1990-01-01

    Recent advances in the efficient production of high purity radioiodine (123I) and new efficient radiolabeling techniques have allowed the development of new classes of cardiovascular radiopharmaceuticals. These include 123I-labeled fatty acids to assess myocardial metabolism, 123I-metaiodobenzylguanidine (MIBG) for myocardial neuronal activity, labeled monoclonal antibodies for myocardial necrosis, and labeled lipoproteins for receptor concentration. 123I-labeled fatty acids and MIBG are under clinical investigation with encouraging results. 123I- and 111In-labeled fragments of monoclonal antibodies to myosin have been used for imaging myocardial necrosis in humans. The development of radiotracers for imaging of cholinergic and adrenergic receptors is still in the experimental stage. Recent advances in imaging instrumentation and radiopharmaceuticals have resulted in cardiac imaging applications beyond blood pool ventriculography, perfusion, and infarct-avid imaging. Developments of radioiodine (123I)-labeled agents promise to play an important role in the assessment of myocardial metabolism, neuronal activity, and receptor concentration. The chemistry of iodine is well defined compared with that of 99mTc; therefore, iodine isotopes are well suited for labeling biologically important molecules. Among the iodine isotopes, 123I has nearly ideal nuclear properties for nuclear medical applications with a 13.3-hour half-life (T1/2) and 159 keV gamma emission (83%). Despite the nearly ideal chemical and nuclear properties of 123I, the widespread application of 123I-based radiopharmaceuticals in clinical practice has been limited by high production costs (123I is produced in a cyclotron), relatively limited availability, and the presence of undesirable radionuclidic impurities (124I, T1/2 = 4.2 days; 125I, T1/2 = 60 days; 126I, T1/2 = 13.1 days). 77 references

  8. Diagnosis and treatment of a carcinoid tumor using iodine-131 meta-iodobenzylguanidine

    International Nuclear Information System (INIS)

    Hoefnagel, C.A.; Den Hartog Jager, F.C.; Van Gennip, A.H.; Marcuse, H.R.; Taal, B.G.

    1986-01-01

    Scintigraphy using I-131 meta-iodobenzylguanidine has been introduced as an effective method to detect pheochromocytomas and neuroblastomas, and the radiopharmaceutical also is applied in therapy of these tumors. The authors present a case of a metastatic gastric carcinoid tumor, another neural crest tumor, concentrating I-131 MIBG, which was documented by conventional scintigraphy and SPECT in correlation with CT scans and colloid scintigrams of the liver. Two therapeutic attempts in this patient, using I-131 MIBG, are described. The metabolic basis of this phenomenon is discussed, and the importance of I-131 MIBG imaging in the detection of neural crest tumors is underlined

  9. Assessment of endogenous dopamine release by methylphenidate challenge using iodine-123 iodobenzamide single-photon emission tomography

    International Nuclear Information System (INIS)

    Booij, J.; Korn, P.; Linszen, D.H.; Royen, E.A. van

    1997-01-01

    This double-blind, placebo-controlled study assessed pharmacologically induced endogenous dopamine (DA) release in healthy male volunteers (n=12). Changes in endogenous DA release after injection of the psychostimulant drug methylphenidate were evaluated by single-photon emission tomography (SPET) and constant infusion of iodine-123 iodobenzamide ([ 123 I[IBZM), a D 2 receptor radioligand that is sensitive to endogenous DA release. Methylphenidate induced displacement of striatal [ 123 I[IBZM binding, resulting in a significantly decrease in the specific to non-specific [ 123 I[IBZM uptake ratio (average: 8.6%) in comparison with placebo (average: -1.9%). Moreover, injection of methylphenidate induced significant behavioural responses on the following items: excitement, anxiety, tension, and mannerisms and posturing. The results of this study demonstrate the feasibility of using constant infusion of [ 123 I[IBZM and SPET imaging to measure endogenous DA release after methylphenidate challenge and to investigate neurochemical aspects of behaviour. (orig.). With 2 figs., 1 tab

  10. The results of questionnaire on quantitative assessment of {sup 123}I-metaiodobenzylguanidine myocardial scintigraphy in heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Tsunehiko [Osaka Univ., Suita (Japan). Medical school; Sugishita, Yasurou; Sasaki, Yasuhito

    1997-12-01

    This study was done by working group under the cooperation between Japanese Society of Nuclear Medicine and Japanese Circulation Society. We evaluated the usefulness of quantitative assessment of {sup 123}I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy in heart failure by the results of questionnaire. Forty-nine (72.1%) of 68 selected institutions participated in this study. The incidence of MIBG myocardial scintigraphy used in heart failure was 41.1%. The imaging protocol was mostly done by both planar and SPECT at 15 min and 3.6 hr after intravenous injection of 111 MBq of MIBG. The quantitative assessment was mostly done by heart/mediastinum (H/M) ratio and washout rate analysis based on planar imaging. The mean normal value of H/M ratio were 2.34{+-}0.36, and 2.49{+-}0.40, at early and delayed images, respectively. The normal value of washout rate was 27.74{+-}5.34%. On the other hand, those of H/M ratio in heart failure were 1.87{+-}0.27, and 1.75{+-}0.24, at early and delayed images, respectively. That of washout rate was 42.30{+-}6.75%. These parameters were very useful for the evaluation of heart failure. In conclusion, MIBG myocardial scintigraphy was widely used for not only early detection and severity assessment, but also indication for therapy and prognosis evaluation in heart failure patients. (author)

  11. 123I-MIBG myocardial imaging in hypertensive patients. Abnormality progresses with left ventricular hypertrophy

    International Nuclear Information System (INIS)

    Mitani, Isao; Sumita, Shinichi; Takahashi, Nobukazu; Ochiai, Hisao; Ishii, Masao

    1996-01-01

    Twenty-seven patients with essential hypertension were prospectively studied with 123 I-labeled metaiodobenzyl-guanidine ( 123 I-MIBG) to assess the presence and location of impaired sympathetic innervation in hypertrophied myocardium. Thirteen patients had left ventricular hypertrophy on echocardiography, and 14 had normal echocardiograms. The wash-out ratio of 123 I-MIBG in these two groups did not differ significantly (35.3±6.1 and 35.4±5.1) but was higher than in control subjects (29.4±6.7). The delayed heart-to-mediastinum count ratio was lower in the patients with hypertrophy than in the patients without hypertrophy (1.93±0.28 and 2.22±0.21; p<0.05) and the control subjects (1.93±0.28 and 2.33±0.25; p<0.05). On SPECT imaging, abnormalities in segmental uptake were frequent at the posterior and postero-lateral wall in both groups, although the hypertrophic group had more significant impairment. Our results lead to the hypothesis that hypertension in more advanced stages may be associated not only with hypertrophic changes but also with more advanced regional impairment of cardiac sympathetic innervation. (author)

  12. Comparison of parameters of 123I-metaiodobenzylguanidine scintigraphy for differential diagnosis in patients with parkinsonism. Correlation with clinical features

    International Nuclear Information System (INIS)

    Uchiyama, Yumiko; Momose, Mitsuru; Kondo, Chisato; Kusakabe, Kiyoko; Uchiyama, Shinichiro

    2011-01-01

    The purpose of this study was to estimate the diagnostic accuracy of 123 I-metaiodobenzylguanidine (MIBG) scintigraphy to diagnose Lewy body disease (LBD), including Parkinson's disease (PD) and dementia with Lewy bodies, and to clarify the relationship between MIBG parameters and the clinical findings. One hundred-and-forty-four patients with parkinsonism without diabetes mellitus or a history of cardiac disease were retrospectively selected in the study. Clinical diagnosis was confirmed by follow-up during more than 6 months by neurologists. All patients underwent MIBG imaging at 15 min (initial) and 4 h (delayed) after the tracer injection, and clinical features such as Hoehn and Yahr (H-Y) classification or symptoms specific to parkinsonism were also investigated. The heart to mediastinum ratio (H/M) and the washout ratio (WR) of MIBG were calculated, and correlation with the clinical features was analyzed. Ninety-seven and 47 patients were diagnosed as LBD and Parkinson's syndrome (PS), respectively. Initial and delayed H/M were significantly lower and WR was significantly higher in LBD than in PS (p<0.0001). The initial H/M was independently correlated with tremor (F value 10.45), hesitation (F=4.49), and hallucinations (F=5.09) (p<0.0001). The sensitivity and specificity for the diagnosis of LBD were 64.9 and 87.2% with initial H/M, 78.4 and 68.1% with delayed H/M, and 80.4 and 61.7% with WR, respectively. Using multivariate analysis, initial H/M (F=39.33) and tremor (F=10.46) were independently correlated to the diagnosis of LBD (r=0.562, p<0.0001) among the MIBG and various clinical parameters. The initial H/M was the most useful of the 3 different parameters of MIBG for the diagnosis of LBD, but had low sensitivity. WR and delayed H/M had no incremental value to initial H/M for the diagnosis of PD. Careful long-term follow-up is needed for patients with parkinsonism who are clinically diagnosed as LBD with normal initial H/M, or diagnosed as no LBD with

  13. The therapeutic use of I-131 meta-iodobenzylguanidine (MIBG) in neuroblastoma

    International Nuclear Information System (INIS)

    Hartmann, O.; Lumbroso, J.D.; Lemerle, J.; Schlumberger, M.; Parmentier, C.; Ricard, M.; Aubert, B.; Coornaert, S.; Merlin, L.

    1988-01-01

    Despite the use of intensified conventional chemotherapy the complete response rate of advanced neuroblastoma remains low. The use of high-dose chemo-radiotherapy followed by bone marrow transplantation (BMT) improved the duration of disease free survival but, even after these high-dose regimens the relapse rate remains high. Metaiodobenzylguanidine (MIBG) labelled with I-131 or I-123 can be used for scintigraphic imaging of neuroblastoma. In order to evaluate the therapeutic role of I-131-MIBG in the treatment of neuroblastoma patients, a phase II study was performed in 12 patients. Results are presented in this paper

  14. Delayed autonomic neuropathy in a patient with diethylene glycol poisoning: a case report.

    Science.gov (United States)

    Kamada, Hiroki; Suzuki, Hideaki; Yamamoto, Saori; Nomura, Ryosuke; Kushimoto, Shigeki

    2017-07-01

    A 72-year-old man presented to our hospital after ingesting insecticide containing approximately 2 mL/kg diethylene glycol, which exceeded the lethal dose of 1 mL/kg. The patient recovered from critical symptoms on acute phase until day 3, but received artificial ventilation for muscle weakness secondary to sensorimotor neuropathy on days 11-54. Even after marked improvement from sensorimotor neuropathy, the patient continued to complain of orthostatic hypotension. Autonomic neuropathy was identified by positive result of a head-up tilt test, and reduction in coefficient of variation of R-R intervals and cardiac iodine-123-metaiodobenzylguanidine uptake for the assessment of cardiac sympathetic activity. The patient's symptoms fully recovered 2 years after the exposure to diethylene glycol. This case shows the first report of delayed autonomic neuropathy after recovery from severe sensorimotor neuropathy, and suggests the importance of continuous monitoring for late-onset neurological complications.

  15. Assessment of DNA double-strand breaks induced by intravascular iodinated contrast media following in vitro irradiation and in vivo, during paediatric cardiac catheterization.

    Science.gov (United States)

    Gould, Richard; McFadden, Sonyia L; Horn, Simon; Prise, Kevin M; Doyle, Philip; Hughes, Ciara M

    2016-01-01

    Paediatric cardiac catheterizations may result in the administration of substantial amounts of iodinated contrast media and ionizing radiation. The aim of this work was to investigate the effect of iodinated contrast media in combination with in vitro and in vivo X-ray radiation on lymphocyte DNA. Six concentrations of iodine (15, 17.5, 30, 35, 45, and 52.5 mg of iodine per mL blood) represented volumes of iodinated contrast media used in the clinical setting. Blood obtained from healthy volunteers was mixed with iodinated contrast media and exposed to radiation doses commonly used in paediatric cardiac catheterizations (0 mGy, 70 mGy, 140 mGy, 250 mGy and 450 mGy). Control samples contained no iodine. For in vivo experimentation, pre and post blood samples were collected from children undergoing cardiac catheterization, receiving iodine concentrations of up to 51 mg of iodine per mL blood and radiation doses of up to 400 mGy. Fluorescence microscopy was performed to assess γH2AX-foci induction, which corresponded to the number of DNA double-strand breaks. The presence of iodine in vitro resulted in significant increases of DNA double-strand breaks beyond that induced by radiation for ≥ 17.5 mg/mL iodine to blood. The in vivo effects of contrast media on children undergoing cardiac catheterization resulted in a 19% increase in DNA double-strand breaks in children receiving an average concentration of 19 mg/mL iodine to blood. A larger investigation is required to provide further information of the potential benefit of lowering the amount of iodinated contrast media received during X-ray radiation investigations. Copyright © 2015 John Wiley & Sons, Ltd.

  16. A phantom study : should (124) I-mIBG PET/CT replace (123) I-mIBG SPECT/CT?

    NARCIS (Netherlands)

    Beijst, Casper; de Keizer, Bart; Lam, Marnix G E H; Janssens, Geert O; Tytgat, Godelieve A M; de Jong, Hugo W A M

    2017-01-01

    PURPOSE: The isotope (123) I is commonly labeled with meta-iodobenzylguanidine (mIBG) for imaging of neuroendocrine tumors, such as pheochromocytomas and neuroblastomas. (123) I-mIBG SPECT/CT imaging is performed for staging, follow-up and selection of patients for treatment with (131) I mIBG. As an

  17. Preparation of iodine-123 labeled AM251: a potential SPECT radioligand for the brain cannabinoid CB1 receptor

    International Nuclear Information System (INIS)

    Lan, Ruoxi; Makriyannis, Alexandros; Gatley, S.J.

    1996-01-01

    We report the synthesis and labeling with iodine-123 of N-(piperidin-1-yl)-5-(4-iodophenyl)-1-(2, 4-dichlorophenyl)-4-methyl-1H-pyrazole-3-carboxamide (AM251). This compound is an analog of the recently described cannabinoid receptor antagonist, SR141716A, in which a 4-chlorophenyl group is replaced by 4-iodophenyl. Labeling in good yield (62%) and radiochemical purity (> 95%), and high specific activity (> 2500 Ci/mmol) was achieved by an iododestannylation reaction using the tributyltin precursor, no carrier added I-123 iodide, and chloramine-T. (author)

  18. Preparation of iodine-123 labeled AM251: a potential SPECT radioligand for the brain cannabinoid CB1 receptor

    Energy Technology Data Exchange (ETDEWEB)

    Lan, Ruoxi; Makriyannis, Alexandros [Connecticut Univ., Molecular and Cell Biology Dept., Storrs, CT (United States); Gatley, S.J. [Brookhaven National Lab., Medical Dept., Upton, NY (United States)

    1996-10-01

    We report the synthesis and labeling with iodine-123 of N-(piperidin-1-yl)-5-(4-iodophenyl)-1-(2, 4-dichlorophenyl)-4-methyl-1H-pyrazole-3-carboxamide (AM251). This compound is an analog of the recently described cannabinoid receptor antagonist, SR141716A, in which a 4-chlorophenyl group is replaced by 4-iodophenyl. Labeling in good yield (62%) and radiochemical purity (> 95%), and high specific activity (> 2500 Ci/mmol) was achieved by an iododestannylation reaction using the tributyltin precursor, no carrier added I-123 iodide, and chloramine-T. (author).

  19. Cardiac sympathetic neuronal damage precedes myocardial fibrosis in patients with Anderson-Fabry disease

    International Nuclear Information System (INIS)

    Imbriaco, Massimo; Piscopo, Valentina; Ponsiglione, Andrea; Nappi, Carmela; Puglia, Marta; Dell'Aversana, Serena; Spinelli, Letizia; Cuocolo, Alberto; Pellegrino, Teresa; Petretta, Mario; Riccio, Eleonora; Pisani, Antonio

    2017-01-01

    Cardiac sympathetic denervation may be detectable in patients with Anderson-Fabry disease (AFD), suggesting its usefulness for early detection of the disease. However, the relationship between sympathetic neuronal damage measured by 123 I-metaiodobenzylguanidine (MIBG) imaging with myocardial fibrosis on cardiac magnetic resonance (CMR) is still unclear. Cardiac sympathetic innervation was assessed by 123 I-MIBG single-photon emission computed tomography (SPECT) in 25 patients with genetically proved AFD. Within one month from MIBG imaging, all patients underwent contrast-enhanced CMR. MIBG defect size and fibrosis size on CMR were measured for the left ventricle (LV) and expressed as %LV. Patients were divided into three groups according to MIBG and CMR findings: (1) matched normal, without MIBG defects and without fibrosis on CMR (n = 10); (2) unmatched, with MIBG defect but without fibrosis (n = 5); and (3) matched abnormal, with MIBG defect and fibrosis (n = 10). The three groups did not differ with respect to age, gender, α-galactosidase, proteinuria, glomerular filtration rate, and troponin I, while New York Heart Association class (p = 0.008), LV hypertrophy (p = 0.05), and enzyme replacement therapy (p = 0.02) were different among groups. Although in patients with matched abnormal findings, there was a significant correlation between MIBG defect size and area of fibrosis at CMR (r 2 = 0.98, p < 0.001), MIBG defect size was larger than fibrosis size (26 ± 23 vs. 18 ± 13%LV, p = 0.02). Sympathetic neuronal damage is frequent in AFD patients, and it may precede myocardial damage, such as fibrosis. Thus, 123 I-MIBG imaging can be considered a challenging technique for early detection of cardiac involvement in AFD. (orig.)

  20. Diabetic cardiac autonomic dysfunction. Parasympathetic versus sympathetic

    International Nuclear Information System (INIS)

    Uehara, Akihiko; Kurata, Chinori; Sugi, Toshihiko; Mikami, Tadashi; Shouda, Sakae

    1999-01-01

    Diabetic cardiac autonomic dysfunction often causes lethal arrhythmia and sudden cardiac death. 123 I-Metaiodobenzylguanidine (MIBG) can evaluate cardiac sympathetic dysfunction, and analysis of heart rate variability (HRV) can reflect cardiac parasympathetic activity. We examined whether cardiac parasympathetic dysfunction assessed by HRV may correlate with sympathetic dysfunction assessed by MIBG in diabetic patients. In 24-hour electrocardiography, we analyzed 4 HRV parameters: high-frequency power (HF), HF in the early morning (EMHF), rMSSD and pNN50. MIBG planar images and SPECT were obtained 15 minutes (early) and 150 minutes (late) after injection and the heart washout rate was calculated. The defect score in 9 left ventricular regions was scored on a 4 point scale (0=normal - 3=severe defect). In 20 selected diabetic patients without congestive heart failure, coronary artery disease and renal failure, parasympathetic HRV parameters had a negative correlation with the sum of defect scores (DS) in the late images (R=-0.47 to -0.59, p<0.05) and some parameters had a negative correlation with the washout rate (R=-0.50 to -0.55, p<0.05). In a total of 64 diabetic patients also, these parameters had a negative correlation with late DS (R=-0.28 to -0.35, p<0.05) and early DS (R=-0.27 to -0.32, p<0.05). The progress of diabetic cardiac parasympathetic dysfunction may parallel the sympathetic one. (author)

  1. Prediction of left ventricular functional recovery in patients with acute myocardial infarction using single photon emission computed tomography with thallium-201 and iodine-123-beta-methyl-p-iodophenyl-pentadecanoic acid

    International Nuclear Information System (INIS)

    Hashimoto, Akiyoshi; Nakata, Tomoaki; Nagao, Kazuhiko

    1995-01-01

    The relationships between myocardial perfusion, fatty acid metabolism, and cardiac function were investigated using dual single photon emission computed tomography (SPECT) with thallium and iodine-123-β-methyl-p-iodophenyl-pentadecanoic acid ( 123 I-BMIPP) during the acute ( 10±1 days) and recovery (60±14 days) phases in 29 patients with acute myocardial infarction. There were 18 patients who underwent successful primary coronary angioplasty (PTCA group) and 11 patients who received conservative therapy (non PTCA group). Thallium and BMIPP uptakes were scored visually by a 4-point system and left ventricular ejection fraction (LVEF) was calculated by radionuclide ventriculography. Although significant positive correlations between thallium and 123 I-BMIPP scores were observed during both phases, BMIPP scores were significantly lower than thallium scores in both acute and recovery phases in the PTCA group. No significant difference in thallium and 123 I-BMIPP scores was observed at the recovery phase in the non PTCA group. LVEF significantly correlated with thallium and 123 I-BMIPP scores in both phases in the PTCA group. Furthermore, the difference between thallium and 123 I-BMIPP scores during the acute phase significantly correlated with the improvement of LVEF during the follow-up period in the PTCA group (y=0.92x-0.77, r=0.65, p 123 I-BMIPP SPECT is increased by reperfusion therapy and persists at least until the recovery phase of myocardial infarction. The recovery of left ventricular function depends on the extent of the mismatched uptake, indicating a predictor for functional recovery following acute myocardial infarction. (author)

  2. Demonstration of disturbed free fatty acid metabolism of myocardium in patients with non-insulin-dependent diabetes mellitus as measured with iodine-123-heptadecanoic acid

    International Nuclear Information System (INIS)

    Kuikka, J.T.; Mustonen, J.N.; Uusitupa, M.I.J.; Rautio, P.; Vanninen, E.; Laakso, M.; Laensimies, E.; Kuopio Central Hospital

    1991-01-01

    Myocardial free fatty acid metabolism and left ventricular function were evaluated in 15 middle-aged patients with non-insulin dependent diabetes mellitus (NIDDM) and in 8 healthy control subjects. The study subjects had no evidence of coronary heart disease on the basis of clinical history, exercise ECG or myocardial perfusion scintigraphy. During peak exercise, iodine-123 hepatadecanoic acid (HDA) was intravenously injected. Myocardial activity distribution of 123 I-HDA was measured 10, 30, and 50 min after exercise using single-photon emission tomography (SPET); and then further corrected by free 123 I-iodine. Venous blood samples were drawn for detecting the plasma activity of 123 I. The net extraction of 123 I-HDA into the myocardium was obtained by dividing the corrected tissue 123 I concentration by the integral of the plasma time activity curve. The net extraction was 0.40±0.06 min -1 (mean±SD) patients with NIDDM and 0.38±0.006 min -1 in control subjects (P>0.1), respectively. The faster elimination rate of 123 I-HDA was found in patients with NIDDM (0.029±0.008 min -1 ) than in control subjects (0.022±0.004 min - 1); P 123 I-HDA and the change of LVEF, as well as with exercise load (r=0.68; P<0.01). In conclusion, evidence of an increased fatty acid utilization and triglyceride synthesis rate was observed in the diabetic myocardium. (orig.)

  3. Cardiac neuronal imaging with 123I-meta-iodobenzylguanidine in heart failure: implications of endpoint selection and quantitative analysis on clinical decisions

    International Nuclear Information System (INIS)

    Petretta, Mario; Pellegrino, Teresa; Cuocolo, Alberto

    2014-01-01

    There are a number of radiopharmaceuticals that can be used to investigate autonomic neuronal functions. Among these, the norepinephrine analogue meta-iodobenzylguanidine (MIBG) labelled with 123 I has been widely used and validated as a marker of adrenergic neuron function. The first study addressing the prognostic value of 123 I-MIBG imaging in heart failure (HF) was that of Merlet et al. in 90 patients suffering from either ischaemic or idiopathic cardiomyopathy. After publication of this study, more recent studies have indicated that patients with HF and decreased late heart-to-mediastinum (H/M) ratio or increased myocardial MIBG washout have a worse prognosis than those with normal quantitative myocardial MIBG parameters. However, MIBG scintigraphy has still to reach widespread clinical application mainly because of the value of other cheaper variables such as left ventricular (LV) ejection fraction and brain natriuretic peptide (BNP) plasma levels. The possibility that the detection of mechanical dyssynchrony by innervation imaging might identify patients who would benefit from resynchronization pacing is another area of research interest. In 2010, the landmark AdreView Myocardial Imaging for Risk Evaluation in Heart Failure (ADMIRE-HF) study was published. This trial consisted of two identical open-label phase III studies enrolling patients in 96 sites in North America and Europe to provide prospective validation of the prognostic role of quantitation of sympathetic cardiac innervation using MIBG. The primary endpoint was the relationship between late HIM ratio and time-to-occurrence of the first event among a combination of HF progression, potentially life-threatening arrhythmic event, and cardiac death. The authors found that a HIM ratio <1.6 provided prognostic information beyond LV ejection fraction, BNP, and New York Heart Association (NYHA) functional class at the time of enrolment. In a recent article in this journal, Parker et al. present the results

  4. Synthesis and evaluation of iodine-123 labelled tricyclic tropanes as radioligands for the serotonin transporter

    International Nuclear Information System (INIS)

    Quinlivan, Mitchell; Mattner, Filomena; Papazian, Vahan; Zhou, Jia; Katsifis, Andrew; Emond, Patrick; Chalon, Sylvie; Kozikowski, Alan; Guilloteau, Denis; Kassiou, Michael

    2003-01-01

    The tricyclic tropane analogues (1S,3S,6R,10S)-(Z)-10-(benzoyloxymethyl)-9-(3-chloro-4-iodobenzylidene)-7 -azatricyclo[4.3.1.0 3,7 ]decane, 1, and (1S,3S,6R,10S)-(Z)-9-(3-chloro-4-iodobenzylidene)-7-azatricyclo[4.3.1.0 3,7 ] = decane-10-carboxylic acid methyl ester, 2, have been shown to be potent and selective serotonin transporter (SERT) ligands. They possess nanomolar affinity for the SERT (Ki = 0.06 nM and 1.8 nM respectively) and are suitable for radiolabelling using iodine-123. In the present study we prepared [ 123 I]1 and [ 123 I]2 from the appropriate tributylstannane precursors using acidic media with chloramine-T as the oxidising agent. The radiochemical yield obtained for [ 123 I]1 varied between 50-60% while for [ 123 I]2 the range was 65-80%. Both radioligands were obtained with radiochemical purity > 97% and specific activity estimated to be > 185 GBq/μmol. The biodistribution of [ 123 I]1 demonstrated low degree of brain penetration at 5 min (0.14%ID/g) with a homogenous distribution. The radioactivity cleared quickly from all brain regions with no preferential localization. In comparison, [ 123 I]2 demonstrated on average a higher brain uptake at 5 min (0.5%ID/g). However the distribution of radioactivity was homogenous and cleared to levels similar to [ 123 I]1 at 1 hr post-injection. Pre-administration of citalopram failed to show any significant inhibition of [ 123 I]2 uptake in the rat brain. The high lipophilicity of 1 and 2 (HPLC-derived log P 7.4 values of 6.41 and 4.25 respectively) and in vivo metabolism, seen by high thyroid uptake would explain the absence of any specific binding observed in the rat brain. In view of these results [ 123 I]1 and [ 123 I]2 do not appear to be suitable radioligands for in vivo studies of the SERT

  5. Synthesis and evaluation of iodine-123 labelled tricyclic tropanes as radioligands for the serotonin transporter

    Energy Technology Data Exchange (ETDEWEB)

    Quinlivan, Mitchell; Mattner, Filomena; Papazian, Vahan; Zhou, Jia; Katsifis, Andrew; Emond, Patrick; Chalon, Sylvie; Kozikowski, Alan; Guilloteau, Denis; Kassiou, Michael E-mail: mkassiou@med.usyd.edu.au

    2003-10-01

    The tricyclic tropane analogues (1S,3S,6R,10S)-(Z)-10-(benzoyloxymethyl)-9-(3-chloro-4-iodobenzylidene)-7 -azatricyclo[4.3.1.0{sup 3,7}]decane, 1, and (1S,3S,6R,10S)-(Z)-9-(3-chloro-4-iodobenzylidene)-7-azatricyclo[4.3.1.0{sup 3,7}] = decane-10-carboxylic acid methyl ester, 2, have been shown to be potent and selective serotonin transporter (SERT) ligands. They possess nanomolar affinity for the SERT (Ki = 0.06 nM and 1.8 nM respectively) and are suitable for radiolabelling using iodine-123. In the present study we prepared [{sup 123}I]1 and [{sup 123}I]2 from the appropriate tributylstannane precursors using acidic media with chloramine-T as the oxidising agent. The radiochemical yield obtained for [{sup 123}I]1 varied between 50-60% while for [{sup 123}I]2 the range was 65-80%. Both radioligands were obtained with radiochemical purity > 97% and specific activity estimated to be > 185 GBq/{mu}mol. The biodistribution of [{sup 123}I]1 demonstrated low degree of brain penetration at 5 min (0.14%ID/g) with a homogenous distribution. The radioactivity cleared quickly from all brain regions with no preferential localization. In comparison, [{sup 123}I]2 demonstrated on average a higher brain uptake at 5 min (0.5%ID/g). However the distribution of radioactivity was homogenous and cleared to levels similar to [{sup 123}I]1 at 1 hr post-injection. Pre-administration of citalopram failed to show any significant inhibition of [{sup 123}I]2 uptake in the rat brain. The high lipophilicity of 1 and 2 (HPLC-derived log P{sub 7.4} values of 6.41 and 4.25 respectively) and in vivo metabolism, seen by high thyroid uptake would explain the absence of any specific binding observed in the rat brain. In view of these results [{sup 123}I]1 and [{sup 123}I]2 do not appear to be suitable radioligands for in vivo studies of the SERT.

  6. Iodine-123 N-methyl-4-iododexetimide: a new radioligand for single-photon emission tomographic imaging of myocardial muscarinic receptors

    International Nuclear Information System (INIS)

    Hicks, R.J.; Kassiou, M.; Eu, P.; Katsifis, A.G.; Garra, M.; Power, J.; Najdovski, L.; Lambrecht, R.M.

    1995-01-01

    Cardiac muscarinic receptor ligands suitable for positron emission tomography have previously been characterised. Attempts to develop radioligands of these receptors suitable for single-photon emission tomographic (SPET) imaging have not been successful due to high lung retention and high non-specific binding of previously investigated potential tracers. The purpose of this study was to evaluate the biodistribution and in vivo imaging characteristics of a new radiopharmaceutical, [ 123 I]N-methyl-4-iododexetimide. Biodistribution studies performed in rats showed high cardiac uptake (2.4% ID/g) 10 min after injection with a heart to lung activity ratio of 5:1. Specificity and stereoselectivity of cardiac binding were demonstrated using blocking experiments in rats. Dynamic imaging studies in anaesthetised greyhounds demonstrated rapid and high myocardial uptake and low lung binding with stable heart to lung activity ratios of >2.5:1 between 10 and 30 min, making SPET imaging feasible. Administration of an excess of an unlabelled muscarinic antagonist, methyl-quinuclidinyl benzylate rapidly displaced myocardial activity to background levels and the pharmacologically inactive enantiomer, [ 123 I]N-methyl-4-iodolevetimide, had no detectable cardiac uptake, indicating specific and stereoselective muscarinic receptor binding. SPET revealed higher activity in the inferior than in the anterior wall, this being consistent with previously described regional variation of cardiac parasympathetic innervation. [ 123 I]N-methyl-4-iododexetimide shows promise as an imaging agent for muscarinic receptor distribution in the heart and may be helpful in evaluating diverse cardiac diseases associated with altered muscarinic receptor function, including heart failure and diabetic heart disease. (orig.)

  7. First determination of the heart-to-mediastinum ratio using cardiac dual isotope ({sup 123}I-MIBG/{sup 99m}Tc-tetrofosmin) CZT imaging in patients with heart failure: the ADRECARD study

    Energy Technology Data Exchange (ETDEWEB)

    Bellevre, Dimitri; Desmonts, Cedric [CHU Cote de Nacre, Department of Nuclear Medicine, Caen (France); Manrique, Alain; Agostini, Denis [CHU Cote de Nacre, Department of Nuclear Medicine, Caen (France); EA 4650, Normandie Universite, Caen (France); Legallois, Damien [EA 4650, Normandie Universite, Caen (France); CHU Cote de Nacre, Cardiology Department, Caen (France); Bross, Samy; Baavour, Rafael; Roth, Nathaniel [Spectrum Dynamics, Biosensors, Caesarea (Israel); Blaire, Tanguy; Bailliez, Alban [EA 4650, Normandie Universite, Caen (France); IRIS, Polyclinique du Bois, Nuclear Medicine Department, Lille (France)

    2015-11-15

    Cardiac innervation is assessed using the heart-to-mediastinum ratio (HMR) of metaiodobenzylguanidine (MIBG) on planar imaging using Anger single photon emission computed tomography (A-SPECT). The aim of the study was to determine the HMR of MIBG obtained using a CZT-based camera (D-SPECT; Spectrum Dynamics, Israel) in comparison with that obtained using conventional planar imaging. The ADRECARD study prospectively evaluated 44 patients with heart failure. They underwent planar acquisition using the A-SPECT camera 4 h after {sup 123}I-MIBG injection (236.4 ± 39.7 MBq). To localize the heart using D-SPECT, {sup 99m}Tc-tetrofosmin (753 ± 133 MBq) was administered and dual isotope acquisition was performed using the D-SPECT system. HMR was calculated using both planar A-SPECT imaging and front view D-SPECT cine data. In a phantom study, we estimated a model fitting the A-SPECT and the D-SPECT data that was further applied to correct for differences between the cameras. A total of 44 patients (39 men and 5 women, aged 60 ± 11 years) with ischaemic (31 patients) and nonischaemic (13 patients) cardiomyopathy completed the study. Most patients (28 of 44) were NYHA class II, and the mean left ventricular ejection fraction was 33 ± 7 %. The mean HMR values were 1.34 ± 0.15 and 1.45 ± 0.27 from A-SPECT and D-SPECT, respectively (p < 0.0001). After correction, Lin's concordance correlation showed an almost perfect concordance between corrected D-SPECT HMR and A-SPECT HMR, and Bland-Altman analysis demonstrated a high agreement between the two measurements. The ADRECARD study demonstrated that determination of late HMR during cardiac MIBG imaging using dual isotope ({sup 123}I and {sup 99m}Tc) acquisition on a CZT camera (D-SPECT) is feasible in patients with heart failure. A linear correction based on the phantom study yielded a high agreement between {sup 123}I MIBG HMR obtained using a CZT camera and that from conventional planar imaging. (orig.)

  8. Assessment of myocardial metabolism with iodine-123 heptadecanoic acid: effect of decreased fatty acid oxidation on deiodination

    International Nuclear Information System (INIS)

    Luethy, P.C.; Chatelain, P.; Papageorgiou, I.; Schubiger, A.; Lerch, R.A.

    1988-01-01

    Terminally radioiodinated fatty acid analogs are of potential use for the noninvasive delineation of regional alterations of fatty acid metabolism by gamma imaging. Since radioactivity from extracted iodine-123 heptadecanoic acid [( 123I]HDA) is released from the myocardium in form of free radioiodide (123I-) the present study was performed to determine whether deiodination of [123I]HDA is related to free fatty acid metabolism. Myocardial production of free radioiodide was measured in rat hearts in vitro and in vivo both under control conditions and after inhibition of fatty acid oxidation. In isolated rat hearts perfused at constant flow with a medium containing [123I]HDA, release of 123I- was markedly reduced during cardioplegia and pharmacologic inhibition of mitochondrial fatty acid transfer with POCA by 67% (p less than 0.005) and 72% (p less than 0.005), respectively. In fasted rats in vivo, 1 min after i.v. injection of [123I]HDA, 51 +/- 5% of myocardial radioactivity was recovered in the aqueous phase, containing free iodide, of myocardial lipid extracts. Aqueous activity was significantly decreased in fed (20 +/- 2%; p less than 0.002) and POCA pretreated (30 +/- 3.7%; p less than 0.05) animals exhibiting reduced oxidation of [14C]palmitate. Thus, deiodination of [123I]HDA was consistently reduced during inhibition of fatty acid oxidation in vitro and in vivo. The results apply to the interpretation of myocardial clearance curves of terminally radioiodinated fatty acid analogs

  9. Iodine-123 (123I) is promising radiopharmaceutical in the radionuclide diagnostics

    International Nuclear Information System (INIS)

    Tazhedinov, I.T.

    2003-01-01

    In the paper some advantages of the radiopharmaceuticals with 123 I against 99m Tc preparations are shown. It is noted that the 123 I is the most favourable among cyclotron radionuclides for radionuclide diagnostics by it nuclear-physical characteristics. With application of 123 I it is possible to attain a significant progress in the thyroid examination. 123 I labelled preparations should have a high bond strength providing the high information valuation of examinations

  10. Prognostic significance of myocardial imaging with iodine-123 beta-methyl-p-iodophenyl-pentadecanoic acid in patients with angina pectoris

    International Nuclear Information System (INIS)

    Hatano, Tsuguhisa; Chikamori, Taishiro; Kamada, Tatsuya; Morishima, Takayuki; Hida, Satoshi; Yanagisawa, Hidefumi; Iino, Hitoshi; Yamashina, Akira

    2001-01-01

    To assess the clinical significance of iodine-123 beta-methyl-p-iodophenyl-pentadecanoic acid (BMIPP) single photon emission computed tomography (SPECT), the predictive value of BMIPP imaging in patients with angina pectoris was evaluated. One hundred seventy-four patients who underwent BMIPP imaging in our institution were aged 61.8±11 years. One hundred thirty-five patients had stable angina and 39 had unstable angina at the time of examination. Patients with previous myocardial infarction or myocardial disorders were excluded. Early and delayed images were acquired in BMIPP SPECT, and the images were analyzed visually. Cardiac events were classified into hard and soft events: the former consisted of cardiac death and nonfatal myocardial infarction, and the latter included coronary revascularization and heart failure. The findings of BMIPP imaging were normal in 82 patients and abnormal in 92. During follow-up of 15.5±9.5 months, hard events were observed in 4 patients and soft events in 53. In patients with normal BMIPP imaging, soft events were observed in nine patients, but no hard event was encountered. Furthermore, in patients with both normal BMIPP and stress thallium imagings, no cardiac event was observed during 2 years. In contrast, 4 hard events and 44 soft events occurred in patients with abnormal BMIPP imaging. Patients with abnormal BMIPP imaging had a higher incidence of soft events than those with normal BMIPP imaging, regardless of the type of angina (16/62 vs 3/73, p<0.0005 for stable angina; 28/30 vs 6/9, p<0.0001 for unstable angina). The finding of BMIPP imaging correlates well with the mid-term prognosis of patients with angina pectoris. Since BMIPP SPECT is performed without stress to the patient, this imaging modality is important in evaluating patients with stable or unstable angina. (author)

  11. Multiple endocrine neoplasia detection on I-123 MIBG imaging

    International Nuclear Information System (INIS)

    Reinhardt, C.A.; McEwan, L.M.; Wong, J.C.H.

    2000-01-01

    Full text: An 123 I meta-iodobenzylguanidine (MIBG) scan was performed on a 54-year-old lady with familial phaeochromocytoma, to evaluate for bilateral or extra-adrenal disease. She has hypertension with raised catecholamines and CT evidence of a right adrenal phaeochromocytoma, and a female sibling with bilateral phaeochromocytoma. Thyroid blockade using Lugol's Iodine was given orally prior to intravenous administration of 370 MBq 123 I MIBG. Planar and SPECT imaging were acquired at 24 hours. There was intense uptake in the known right phaeochromocytoma. An unexpected finding was focal intense uptake in the region of the right thyroid lobe, which may be either a functioning paraganglioma arising from the cervical sympathetic ganglia or a medullary thyroid carcinoma (MTC). At 48 hours, a further image of the neck showed no changes. This was followed by a standard injection of 150 MBq 99 Tc m pertechnetate for thyroid scanning. Imaging obtained on 99 Tc m energy window setting showed a large hypofunctioning region in the right thyroid lobe, corresponding in location to the focal 123 I MIBG uptake. This is in keeping with a MTC, a neuroendocrine tumour, as other thyroid carcinomas are non-MIBG avid. A subsequent serum calcitonin assay showed elevated levels. The patient underwent surgical removal of the right phaeochromocytoma followed several weeks later by a right hemithyroidectomy. Histological reports confirmed the tumour diagnoses. The patient's familial phaeochromocytoma is therefore part of the multiple endocrine neoplasia syndrome Type 2A (MEN 2A). To date, biochemistry has not shown any evidence of hyperparathyroidism which occurs in 15-20 per cent of patients with MEN 2A. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  12. Use of I-123 MIBG cardiac scintigraphy to assess the impact of carvedilol on cardiac adrenergic neuronal function in childhood dilated cardiomyopathy; Interet de la scintigraphie cardiaque a l'I-123 MIBG pour evaluer l'impact du carvedilol sur la fonction neuronale adrenergique cardiaque dans les myocardiopathies dilatees de l'enfant

    Energy Technology Data Exchange (ETDEWEB)

    Maunoury, C. [Hopital Europeen Georges Pompidou (HEGP), Dept. de Physiologie et Radio-Isotopes, 75 - Paris (France); Acar, P. [Centre Hospitalier Universitaire, Service de Cardiologie Pediatrique, Hopital des Enfants, 31 - Toulouse (France); Sidi, D. [Centre Hospitalier Universitaire Necker-Enfants-Malades, 75 - Paris (France)

    2006-04-15

    I-123 MIBG cardiac scintigraphy is a useful tool to assess cardiac adrenergic neuronal function, which is impaired in children with dilated cardiomyopathy (DCM). In adults with DCM, long-term treatment with carvedilol improves both cardiac adrenergic neuronal function and left ventricular function. The aim of this prospective study was to evaluate the impact of carvedilol on cardiac adrenergic neuronal function and on left ventricular function in seventeen patients (11 female, 6 male, mean age 39 {+-} 57 months, range 1 - 168 months) with DCM. All patients underwent I-123 MIBG cardiac scintigraphy and equilibrium radio-nuclide angiography before and after a 6 month period of carvedilol therapy. A static anterior view of the chest was acquired 4 hours after intravenous injection of 20 to 75 MBq of I-123 MIBG. Cardiac neuronal uptake of I-123 MIBG was measured using the heart to mediastinum count ratio (HMR). Radionuclide left ventricular ejection fraction (LVEF) was assessed following a standard protocol. There was no major cardiac events (death or transplantation) during the follow-up period. I-123 MIBG cardiac uptake and left ventricular function respectively increased by 38% and 65% after 6 months of treatment with carvedilol (HMR 223 {+-} 49% vs 162 {+-} 26%, p < 0.0001 and LVEF = 43 {+-} 17% vs 26 {+-} 11%, p < 0.0001). Carvedilol can improve cardiac adrenergic neuronal function and left ventricular function in children with DCM. Further studies are needed to assess the relationship between improvement in I-123 MIBG cardiac uptake and the beneficial effects of carvedilol on morbidity and mortality. (authors)

  13. Quantitative renal cinescintigraphy with iodine-123 hippuran methodological aspects, kit for labeling of hippuran

    International Nuclear Information System (INIS)

    Mehdaoui, A.; Pecking, A.; Delorme, G.; Mathonnat, F.; Debaud, B.; Bardy, A.; Coornaert, S.; Merlin, L.; Vinot, J.M.; Desgrez, A.; Gambini, D.; Vernejoul, P. de.

    1981-08-01

    The development of an extemporaneous kit for the labeling of ortho-iodo-hippuric acid (Hippuran) with iodine 123 allows the performance of a routine quantitative renal cinescintigraphy providing in 20 minutes, and in an absolutely non-traumatic way, a very complete renal morphofunctional study including: a cortical renal scintigraphy, sequential scintigraphies of excretory tract, renal functional curves, tubular, global, and separate clearances for each kidney. This functional quantitative investigation method should take a preferential place in the routine renal balance. The methodology of the technique is explained and compared to classical methods for estimation of tubular, global and separate clearances [fr

  14. Cardiac neuronal imaging with {sup 123}I-meta-iodobenzylguanidine in heart failure: implications of endpoint selection and quantitative analysis on clinical decisions

    Energy Technology Data Exchange (ETDEWEB)

    Petretta, Mario [University Federico II, Department of Translational Medicine, Naples (Italy); Pellegrino, Teresa [National Council of Research, Institute of Biostructure and Bioimaging, Naples (Italy); Cuocolo, Alberto [University Federico II, Department of Advanced Biomedical Sciences, Naples (Italy)

    2014-09-15

    There are a number of radiopharmaceuticals that can be used to investigate autonomic neuronal functions. Among these, the norepinephrine analogue meta-iodobenzylguanidine (MIBG) labelled with {sup 123}I has been widely used and validated as a marker of adrenergic neuron function. The first study addressing the prognostic value of {sup 123}I-MIBG imaging in heart failure (HF) was that of Merlet et al. in 90 patients suffering from either ischaemic or idiopathic cardiomyopathy. After publication of this study, more recent studies have indicated that patients with HF and decreased late heart-to-mediastinum (H/M) ratio or increased myocardial MIBG washout have a worse prognosis than those with normal quantitative myocardial MIBG parameters. However, MIBG scintigraphy has still to reach widespread clinical application mainly because of the value of other cheaper variables such as left ventricular (LV) ejection fraction and brain natriuretic peptide (BNP) plasma levels. The possibility that the detection of mechanical dyssynchrony by innervation imaging might identify patients who would benefit from resynchronization pacing is another area of research interest. In 2010, the landmark AdreView Myocardial Imaging for Risk Evaluation in Heart Failure (ADMIRE-HF) study was published. This trial consisted of two identical open-label phase III studies enrolling patients in 96 sites in North America and Europe to provide prospective validation of the prognostic role of quantitation of sympathetic cardiac innervation using MIBG. The primary endpoint was the relationship between late HIM ratio and time-to-occurrence of the first event among a combination of HF progression, potentially life-threatening arrhythmic event, and cardiac death. The authors found that a HIM ratio <1.6 provided prognostic information beyond LV ejection fraction, BNP, and New York Heart Association (NYHA) functional class at the time of enrolment. In a recent article in this journal, Parker et al. present

  15. Quantification of Iodine-123-FP-CIT SPECT with a resolution-independent method

    International Nuclear Information System (INIS)

    Dobbeleir, A.A.; Ham, H.R.; Hambye, A.E.; Vervaet, A.M.

    2005-01-01

    Accurate quantification of small-sized objects by SPECT is hampered by the partial volume effect. The present work evaluates the magnitude of this phenomenon with Iodine- 123 in phantom studies, and presents a resolution- independent method to quantify striatal I-123 FP-CIT uptake in patients. At first five syringes with internal diameters varying between 9 and 29mm and an anthropomorphic striatal phantom were filled with known concentrations of Iodine-123 and imaged by SPECT using different collimators and radii of rotation. Data were processed with and without scatter correction. From the measured activities, calibration factors were calculated for each specific collimator. Then a resolution-independent method for FP-CIT quantification using large regions of interest was developed and validated in 34 human studies (controls and patients) acquired in 2 different hospitals, by comparing its results to those obtained by a semi- quantitative striatal-to-occipital analysis. Taking the injected activity and decay into account, the measured counts/volume could be converted into absolute tracer concentrations. For the fan-beam, high resolution and medium energy collimators, the measured maximum activity in comparison to the 29 mm-diameter syringe was respectively 38%, 16% and 9% for the 9 mm-diameter syringe and 82%, 80% and 30% for the 16 mm syringe, and not significantly modified after scatter correction. For the anthropomorphic phantom, the error in measurement in % of the true concentration ranged between 0.3-9.5% and was collimator dependent. Medium energy collimators yielded the most homogeneous results. In the human studies, inter- observer variability was 11.4% for the striatal-to-occipital ratio and 3.1% for the resolution-independent method, with correlation coefficients >0.8 between both. The resolution- independent method was 89%-sensitive and 100%-specific to separate the patients without and with abnormal FP-CIT uptake (accuracy: 94%). Also the

  16. The significance of 123I-BMIPP delayed scintigraphic imaging in cardiac patients.

    Science.gov (United States)

    Akashi, Yoshihiro J; Kida, Keisuke; Suzuki, Kae; Inoue, Koji; Kawasaki, Kensuke; Yamauchi, Masahiro; Musha, Haruki; Anker, Stefan D

    2007-04-25

    Earlier studies have not fully investigated the significance of radionuclide planar imaging in cardiac patients using the fatty acid analogue 123I-beta-methyl-iodophenylpentadecanoic acid (123I-BMIPP). This study was to clarify the effectiveness of 123I-BMIPP in assessing the heart-to-mediastinum ratio (H/M) and myocardial washout rate (WR) in patients with heart disease. Myocardial 123I-BMIPP imaging was performed in 33 patients (20 with chronic heart failure [CHF] and 13 with stable angina pectoris [AP]) and 11 control subjects. Myocardial 123I-BMIPP planner images were obtained 30 min (early image) and 4 h (delayed image) after tracer injection. The left ventricular ejection fraction (LVEF) was measured by quantitative gated single photon emission computed tomography. The concentration of plasma brain natriuretic peptide (BNP) was measured before the scintigraphic study. (1) Delayed H/M was much lower in CHF than in AP (1.93 +/- 0.37 vs. 2.21 +/- 0.38, p acid metabolism disorders in patients with heart disease in both masked and unmasked conditions.

  17. Iodine-123 labelled nor-β-CIT binds to the serotonin transporter in vivo as assessed by biodistribution studies in rats

    International Nuclear Information System (INIS)

    Booij, J.; Knol, R.J.J.; Reneman, L.; De Bruin, K.; Van Royen, E.A.; Janssen, A.G.M.

    1998-01-01

    Iodine-123 labelled 2β-carbomethoxy-3β-(4-iodophenyl)nortropane (nor-β-CIT), a radioiodinated cocaine analogue, was evaluated as an agent for the in vivo labelling of serotonin transporters by biodistribution studies in rats. Intravenous injection of [ 123 I]nor-β-CIT resulted in high accumulation of radioactivity in brain areas with high densities of serotonin (hypothalamus) and dopamine transporters (striatum), although the binding was less pronounced in the hypothalamus. While binding of [ 123 I]nor-β-CIT in the hypothalamus was blocked significantly by fluvoxamine (a selective serotonin transporter blocker) but not by GBR12,909 (a selective dopamine transporter blocker), the opposite was observed in the striatum. The results of this study indicate that [ 123 I]nor-β-CIT, although not being a selective radioligand, binds specifically to serotonin transporters in the hypothalamus in vivo and thus suggest that [ 123 I]nor-β-CIT promises to be a suitable radioligand for single-photon emission tomography imaging of serotonin transporters in humans. (orig.)

  18. Cardiac sympathetic neuronal damage precedes myocardial fibrosis in patients with Anderson-Fabry disease

    Energy Technology Data Exchange (ETDEWEB)

    Imbriaco, Massimo; Piscopo, Valentina; Ponsiglione, Andrea; Nappi, Carmela; Puglia, Marta; Dell' Aversana, Serena; Spinelli, Letizia; Cuocolo, Alberto [University Federico II, Department of Advanced Biomedical Sciences, Naples (Italy); Pellegrino, Teresa [National Council of Research, Institute of Biostructure and Bioimaging, Naples (Italy); Petretta, Mario [University Federico II, Department of Translational Medical Sciences, Naples (Italy); Riccio, Eleonora; Pisani, Antonio [University of Naples Federico II, Department of Public Health, Naples (Italy)

    2017-12-15

    Cardiac sympathetic denervation may be detectable in patients with Anderson-Fabry disease (AFD), suggesting its usefulness for early detection of the disease. However, the relationship between sympathetic neuronal damage measured by {sup 123}I-metaiodobenzylguanidine (MIBG) imaging with myocardial fibrosis on cardiac magnetic resonance (CMR) is still unclear. Cardiac sympathetic innervation was assessed by {sup 123}I-MIBG single-photon emission computed tomography (SPECT) in 25 patients with genetically proved AFD. Within one month from MIBG imaging, all patients underwent contrast-enhanced CMR. MIBG defect size and fibrosis size on CMR were measured for the left ventricle (LV) and expressed as %LV. Patients were divided into three groups according to MIBG and CMR findings: (1) matched normal, without MIBG defects and without fibrosis on CMR (n = 10); (2) unmatched, with MIBG defect but without fibrosis (n = 5); and (3) matched abnormal, with MIBG defect and fibrosis (n = 10). The three groups did not differ with respect to age, gender, α-galactosidase, proteinuria, glomerular filtration rate, and troponin I, while New York Heart Association class (p = 0.008), LV hypertrophy (p = 0.05), and enzyme replacement therapy (p = 0.02) were different among groups. Although in patients with matched abnormal findings, there was a significant correlation between MIBG defect size and area of fibrosis at CMR (r{sup 2} = 0.98, p < 0.001), MIBG defect size was larger than fibrosis size (26 ± 23 vs. 18 ± 13%LV, p = 0.02). Sympathetic neuronal damage is frequent in AFD patients, and it may precede myocardial damage, such as fibrosis. Thus, {sup 123}I-MIBG imaging can be considered a challenging technique for early detection of cardiac involvement in AFD. (orig.)

  19. Association between left ventricular regional sympathetic denervation and mechanical dyssynchrony in phase analysis: a cardiac CZT study

    International Nuclear Information System (INIS)

    Gimelli, Alessia; Genovesi, Dario; Giorgetti, Assuero; Kusch, Annette; Liga, Riccardo; Marzullo, Paolo

    2014-01-01

    To evaluate the relationships among myocardial sympathetic innervation, perfusion and mechanical synchronicity assessed with cardiac cadmium-zinc-telluride (CZT) scintigraphy. A group of 29 patients underwent an evaluation of myocardial perfusion with 99m Tc-tetrofosmin CZT scintigraphy and adrenergic innervation with 123 I-metaiodobenzylguanidine (MIBG) CZT scintigraphy. The summed rest score (SRS), motion score (SMS) and thickening score (STS), as well as the summed 123 I-MIBG defect score (SS-MIBG), were determined. Regional tracer uptake for both 99m Tc-tetrofosmin and 123 I-MIBG was also calculated. Finally, the presence of significant myocardial mechanical dyssynchrony was evaluated in phase analysis on gated CZT images and the region of latest mechanical activation identified. Significant mechanical dyssynchrony was present in 17 patients (59 %) and associated with higher SRS (P = 0.030), SMS (P 123 I-MIBG uptake (P = 0.012) that overwhelmed the effect of depressed regional perfusion. Left ventricular mechanical dyssynchrony is associated with greater depression in contractile function and greater impairments in regional myocardial perfusion and sympathetic activity. In patients with dyssynchrony, the region of latest mechanical activation is characterized by a significantly altered adrenergic tone. (orig.)

  20. An Unusual Case of Gastrointestinal Bleeding

    Directory of Open Access Journals (Sweden)

    Kristin N. Fiorino

    2011-01-01

    Full Text Available A 10-year-old boy presented with a 3-day history of worsening abdominal pain, fever, emesis and melena. Abdominal ultrasound revealed a right upper quadrant mass that was confirmed by computed tomography angiogram (CTA, which showed an 8 cm well-defined retroperitoneal vascular mass. 123Iodine metaiodobenzylguanidine (123MIBG scan indicated uptake only in the abdominal mass. Subsequent biopsy revealed a paraganglioma that was treated with chemotherapy. This case represents an unusual presentation of a paraganglioma associated with gastrointestinal (GI bleeding and highlights the utility of CTA and 123MIBG in evaluation and treatment.

  1. Clinical efficacy of efonidipine hydrochloride, a T-type calcium channel inhibitor, on sympathetic activities. Examination using spectral analysis of heart rate/blood pressure variabilities and 123I-Metaiodobenzylguanidine myocardial scintigraphy

    International Nuclear Information System (INIS)

    Harada, Kenji; Nomura, Masahiro; Nishikado, Akiyoshi; Uehara, Kouzoh; Nakaya, Yutaka; Ito, Susumu

    2003-01-01

    Dihydropyridine Ca antagonists cause reflex tachycardia related to their hypotensive effects. Efonidipine hydrochloride has inhibitory effects on T-type Ca channels, even as it inhibits reflex tachycardia. In the present study, the influence of efonidipine hydrochloride on heart rate and autonomic nervous function was investigated. Using an electrocardiogram and a tonometric blood pressure measurement, autonomic nervous activity was evaluated using spectral analysis of heart rate/systolic blood pressure variability. Three protocols were used: a single dose of efonidipine hydrochloride was administered orally to healthy subjects with resting heart rate values of 75 beats/min or more (high-heart rate (HR) group) and to healthy subjects with resting heart rate values less than 75 beats/min (low-HR group); efonidipine hydrochloride was newly administered to untreated patients with essential hypertension, and autonomic nervous activity was investigated after a 4-week treatment period; and patients with high heart rate values (≥75 beats/min) who had been treated with a dihydropyridine L-type Ca channel inhibitor for 1 month or more were switched to efonidipine hydrochloride and any changes in autonomic nervous activity were investigated. In all protocols, administration of efonidipine hydrochloride decreased the heart rate in patients with a high heart rate, reduced sympathetic nervous activity, and enhanced parasympathetic nervous activity. In addition, myocardial scintigraphy with 123 I-metaiodobenzylguanidine showed significant improvement in the washout rate and heart to mediastinum (H/M) ratio of patients who were switched from other dihydropyridine Ca antagonists to efonidipine hydrochloride. Efonidipine hydrochloride inhibits increases in heart rate and has effects on the autonomic nervous system. It may be useful for treating hypertension and angina pectoris, and may also have a cardiac protective function. (author)

  2. The progression to permanent atrial fibrillation with congestive heart failure is associated with sympathetic nerve abnormality. A study with I-123 metaiodobenzylguanidine scintigraphy

    International Nuclear Information System (INIS)

    Kodama, Yusuke; Akutsu, Yasushi; Li, Hui-Ling; Kinohira, Yukihiko; Yamanaka, Hideyuki; Shinozuka, Akira; Katagiri, Takashi

    2005-01-01

    The aim of this study was to evaluate the relationship between congestive heart failure (CHF) and atrial fibrillation (AF) using iodine-123 metaiodobenzylguanidine (MIBG) scintigraphic imaging. Ninety-two AF patients (47 male and 45 female patients; mean age, 67±13 years) who did not suffer from structural heart disease or myocardial ischemia underwent MIBG scintigraphy. Global MIBG uptake was assessed by measuring the heart-to-mediastinal ratio (H/M) and washout rate (WR) on planar images, and the abnormal score (AS) was calculated on delayed MIBG single photon emission computed tomography images. Echocardiography was performed within a week after MIBG scintigraphy, to measure left ventricular ejection fraction (EF) and deceleration time (DT). The AF patients were divided into four groups: patients with permanent AF with (n=23, group A) or without (n=19, group B) a history of CHF, and patients with paroxysmal AF with (n=19, group C) or without (n=39, group D) a history of CHF. The H/M ratio was significantly lower in group A than in other groups (2.0±0.6 vs. group B: 2.7±0.6, group C: 2.3±0.5, and group D: 2.6±0.8, P<0.05), and in group C than in group D (P<0.05). Similarly, the WR was significantly higher in group A than in groups B and C (45.9±2.0 vs. group B: 38.9±1.9 and group C: 38.4±2.3, P<0.05). The AS was the highest in group A (19.7±8.2 vs. group B: 7.1±6.6, P<0.01; group C: 11.6±10.6 and group D: 13.5±9.0, P<0.05). The DT was significantly longer in group A than in groups B and D (222.0±59.4 vs. group B: 179.5±49.1, P<0.05 and group D: 177.9±37.1, P<0.01), but did not differ between groups A and C (222.0±59.4 vs. 197.4±51.1). There was no difference in EF among the groups. Although CHF with AF is associated with diastolic dysfunction, the progression to permanent AF from paroxysmal AF with CHF might be caused mainly by sympathetic nerve abnormality. (author)

  3. Reduced cortical distribution volume of iodine-123 iomazenil in Alzheimer's disease as a measure of loss of synapses

    DEFF Research Database (Denmark)

    Soricelli, A; Postiglione, A; Grivet-Fojaja, M R

    1996-01-01

    Iodine-123 labelled iomazenil (IMZ) is a specific tracer for the GABAA receptor, the dominant inhibitory synapse of the brain. The cerebral distribution volume (Vd) of IMZ may be taken as a quantitative measure of these synapses in Alzheimer's disease (AD), where synaptic loss tends indiscriminat...... simultaneously. Reduced values were found in all regions except in the occipital (visual) cortex. In particular, temporal and parietal cortex Vd was significantly (P...

  4. Indocyanine green labeled with 123I for dynamic studies of the hepato-biliary system

    International Nuclear Information System (INIS)

    Lambrecht, R.M.; Ansari, A.N.; Wolf, A.P.; Atkins, H.L.

    1975-01-01

    This report summarizes the results to develop an iodine-123 labeled agent for dynamic studies of the hepato-biliary system. Iodine-123 is an ideal nuclide for radiopharmaceuticals, because of its short half-life (T/sub 1 / 2 / = 13.3 hr); its decay with a high abundance (83%) of 159 keV photons; and the reduced patient radiation exposure (a factor of 100 less than iodine-131). Indocyanine green, a tricarbanocyanine dye, was introduced by Heseltine and co-workers in 1956, has several characteristics which suggested that iodine-123 labeled ICG might be potentially useful for hepatic functional evaluation. The plasma clearance and biliary excretion kinetics of 123 I-ICG (in dogs) will be compared to 131 I-rose bengal and bromosulphalein labeled with iodine-125

  5. Does reducing unnecessary right ventricular pacing improve sympathetic activity and innervation of heart in sinus node disease patients? MVP and SafeR study.

    Science.gov (United States)

    Miyamoto, Mihoko; Kimura, Yuichiro; Hosoda, Junya; Matsumoto, Katsumi; Matsushita, Kohei; Ishikawa, Toshiyuki; Umemura, Satoshi

    2012-01-01

    Ventricular desynchronization imposed by ventricular pacing causes regional disturbances of adrenergic innervation in the left ventricular myocardium and increases the risk of heart failure and atrial fibrillation (AF) in patients with sinus node disease (SND). As a result, decreased iodine-123 metaiodobenzylguanidine (I-(123 )MIBG) uptake occurs in patients with an implanted permanent pacemaker. Fourteen SND patients with an implanted pacemaker equipped with an algorithm for reducing unnecessary right ventricular pacing (RURVP) were enrolled. Pacemakers were programmed to RURVP mode for the first 12 weeks, and then reprogrammed to DDD for the last 12 weeks. At the end of each mode, data on cumulative percent ventricular pacing (%Vp), atrial high rate episodes (%AHR), I-(123 )MIBG myocardial scintigraphy, brain natriuretic peptide (BNP), human atrial natriuretic peptide (hANP), and myocardial damage indices typified by troponin T and C-reactive protein (CRP) were collected. %Vp was lower in RURVP than in DDD (0.2% versus 95.7%, P = 0.00098). BNP, hANP, troponin T, and CRP did not differ significantly between the pacing modes. However, I-(123 )MIBG findings of patients with full ventricular pacing in DDD improved in RURVP. In contrast, among patients without full ventricular pacing in DDD, their I-(123 )MIBG findings did not differ significantly between the pacing modes. In SND patients with normal cardiac function and intact atrioventricular conduction, the reduction of %Vp in RURVP was due to the reduction of ineffective pacing and fusion pacing in DDD. Therefore, these 2 types of pacing do not affect cardiac pump function.

  6. Biodistribution and dosimetry of (iodine-123)-iodomethyl-N,N-diethyltamoxifen, an (anti)oestrogen receptor radioligand

    International Nuclear Information System (INIS)

    Wiele, C. van de; Sutter, J. de; Dierckx, R.A.; Vos, F. de; Dumont, F.; Slegers, G.; Thierens, H.

    1999-01-01

    This study reports on the distribution and radiation dosimetry of iodine-123 labelled trans-Z-iodomethyl-N,N-diethyltamoxifen (123-ITX), a promising radioligand for prediction of the therapeutic efficacy of unlabelled tamoxifen in human breast carcinoma. Whole-body scans were performed up to 24 h after intravenous injection of 123-ITX (mean: 146 MBq, range: 142-148 MBq) in five female volunteers, four with and one without thyroid blockade. Blood samples were taken at various times up to 24 h after injection. Urine was also collected up to 24 h after injection, allowing calculation of renal clearance and interpretation of whole-body clearance. Time-activity curves were generated for the thyroid, heart, brain, breasts, liver and gallbladder by fitting the organ-specific geometric mean counts, obtained from regions of interest. The MIRD formulation was applied to calculate the absorbed radiation doses for various organs. The images showed rapid hepatobiliary excretion, resulting in good imaging conditions for the thoracic region, whereas imaging of the abdominal region was impeded by extensive bowel activity. The breast to non-specific uptake ratio increased over time. 123-ITX was cleared by both the kidneys and the gastrointestinal tract. At 50 h p.i. the mean excretion in the urine was 89.4% (SD 5.7%). If the thyroid was not blocked, it was one of the critical organs. The highest absorbed doses were received by the excretory organs, i.e. the urinary bladder wall, the lower and upper large intestine, and the gallbladder wall. The average effective dose of 123-ITX was estimated to be 0.0084 mSv/MBq. The amount of 123-ITX required for adequate imaging of tumoral uptake results in an acceptable effective dose to the patient. (orig.)

  7. Relationship between quantitative cardiac neuronal imaging with 123I-meta-iodobenzylguanidine and hospitalization in patients with heart failure

    International Nuclear Information System (INIS)

    Parker, Matthew W.; Sood, Nitesh; Ahlberg, Alan W.; Jacobson, Arnold F.; Heller, Gary V.; Lundbye, Justin B.

    2014-01-01

    Hospitalization in patients with systolic heart failure is associated with morbidity, mortality, and cost. Myocardial sympathetic innervation, imaged by 123 I-meta-iodobenzylguanidine ( 123 I-mIBG), has been associated with cardiac events in a recent multicenter study. The present analysis explored the relationship between 123 I-mIBG imaging findings and hospitalization. Source documents from the ADMIRE-HF trial were reviewed to identify hospitalization events in patients with systolic heart failure following cardiac neuronal imaging using 123 I-mIBG. Time to hospitalization was analyzed with the Kaplan-Meier method and compared to the mIBG heart-to-mediastinum (H/M) ratio using multiple-failure Cox regression. During 1.4 years of median follow-up, 362 end-point hospitalizations occurred in 207 of 961 subjects, 79 % of whom had H/M ratio <1.6. Among subjects hospitalized for any cause, 88 % had H/M ratio <1.6 and subjects with H/M ratio <1.6 experienced hospitalization earlier than subjects with higher H/M ratios (log-rank p = 0.003). After adjusting for elevated brain natriuretic peptide (BNP) and time since heart failure diagnosis, a low mIBG H/M ratio was associated with cardiac-related hospitalization (HR 1.48, 95 % CI 1.05 - 2.0; p = 0.02). The mIBG H/M ratio may risk-stratify patients with heart failure for cardiac-related hospitalization, especially when used in conjunction with BNP. Further studies are warranted to examine these relationships. (orig.)

  8. Iodine-123 labelled nor-{beta}-CIT binds to the serotonin transporter in vivo as assessed by biodistribution studies in rats

    Energy Technology Data Exchange (ETDEWEB)

    Booij, J.; Knol, R.J.J.; Reneman, L.; De Bruin, K.; Van Royen, E.A. [Dept. of Nuclear Medicine, Univ. of Amsterdam (Netherlands); Janssen, A.G.M. [Amersham Cygne and Eindhoven University of Technology (Netherlands)

    1998-12-01

    Iodine-123 labelled 2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)nortropane (nor-{beta}-CIT), a radioiodinated cocaine analogue, was evaluated as an agent for the in vivo labelling of serotonin transporters by biodistribution studies in rats. Intravenous injection of [{sup 123}I]nor-{beta}-CIT resulted in high accumulation of radioactivity in brain areas with high densities of serotonin (hypothalamus) and dopamine transporters (striatum), although the binding was less pronounced in the hypothalamus. While binding of [{sup 123}I]nor-{beta}-CIT in the hypothalamus was blocked significantly by fluvoxamine (a selective serotonin transporter blocker) but not by GBR12,909 (a selective dopamine transporter blocker), the opposite was observed in the striatum. The results of this study indicate that [{sup 123}I]nor-{beta}-CIT, although not being a selective radioligand, binds specifically to serotonin transporters in the hypothalamus in vivo and thus suggest that [{sup 123}I]nor-{beta}-CIT promises to be a suitable radioligand for single-photon emission tomography imaging of serotonin transporters in humans. (orig.) With 1 fig., 2 tabs., 15 refs.

  9. Influence of the polyol pathway on norepinephrine transporter reduction in diabetic cardiac sympathetic nerves: implications for heterogeneous accumulation of MIBG

    International Nuclear Information System (INIS)

    Kiyono, Yasushi; Kajiyama, Satomi; Fujiwara, Hiromi; Kanegawa, Naoki; Saji, Hideo

    2005-01-01

    Cardiac scintigraphic studies using 123 I-labeled metaiodobenzylguanidine ([ 123 I]MIBG) have demonstrated heterogeneous myocardial accumulation of MIBG in diabetes. The accumulation has been found to correlate with a heterogeneous decrease in the expression of norepinephrine transporter (NET). In diabetic peripheral nerve tissue, polyol pathways are activated and cause nerve dysfunction and degeneration. However, there has been little research on the polyol pathway and cardiac sympathetic nerves. Therefore, to assess the influence of the polyol pathway on cardiac sympathetic nervous function, we investigated the regional accumulation of MIBG and NET protein expression in diabetic model rats treated with aldose reductase inhibitor (ARI) for the blockade of polyol pathways. Rats were given a single intravenous injection of streptozotocin (n=76, STZ-D rats). Starting the day after STZ injection, ARI was administered daily to 42 of the rats for 4 weeks (ARI-D rats). To assess the cardiac sympathetic nervous function, [ 125 I]MIBG autoradiographic experiments were carried out. Finally, NET protein expression was assessed with a saturation binding assay. The myocardial sorbitol concentration was significantly higher in STZ-D rats than in ARI-D rats. There was no heterogeneous accumulation of MIBG in ARI-D rats. There was a heterogeneous decrease of NET expression in STZ-D rats, but not in ARI-D or control rats. The gathered data indicate that the enhanced polyol pathway correlates with the decrease in regional cardiac sympathetic nervous function, and this impairment may lead to the reduction of NET protein in cardiac sympathetic nerves of the diabetic inferior wall. (orig.)

  10. Cyclotron production of high-purity 123I for medical applications via the 127I(p,5n)123Xe → 123I nuclear reaction

    International Nuclear Information System (INIS)

    Lagunas-Solar, M.C.

    1985-01-01

    The use of iodine-123 in nuclear medicine procedures is well documented in the scientific literature. Also, several methods for its production based on accelerator techniques have been described. Indirectly made 123 I via the 127 I(p,5n) 123 Xe → 123 I reaction produces 123 I of > 99.9% radionuclidic purity, with only 125 I ( 123 I production were developed at the University of California at Davis, where since 1974 the 76-in. isochronous cyclotron of the Crocker Nuclear Laboratory has been used for routine biweekly production of high-purity no-carrier-added 123 I

  11. Quantitation of cardiac sympathetic innervation in rabbits using 11C-hydroxyephedrine PET: relation to 123I-MIBG uptake

    International Nuclear Information System (INIS)

    Nomura, Yusuke; Kajinami, Kouji; Matsunari, Ichiro; Takamatsu, Hiroyuki; Murakami, Yoshihiro; Matsuya, Takahiro; Chen, Wei-Ping; Taki, Junichi; Nakajima, Kenichi; Nekolla, Stephan G.

    2006-01-01

    Although 11 C-hydroxyephedrine ( 11 C-HED) PET is used to map cardiac sympathetic innervation, no studies have shown the feasibility of quantitation of 11 C-HED PET in small- to medium-sized animals. Furthermore, its relation to 123 I-MIBG uptake, the most widely used sympathetic nervous tracer, is unknown. The aims of this study were to establish in vivo sympathetic nerve imaging in rabbits using 11 C-HED PET, and to compare the retention of 11 C-HED with that of 123 I-MIBG. Twelve rabbits were assigned to three groups; control (n=4), chemical denervation by 6-hydroxydopamine (6-OHDA) (n=4) and reserpine treated to inhibit vesicular uptake (n=4). After simultaneous injection of 11 C-HED and 123 I-MIBG, all animals underwent dynamic 11 C-HED PET for 40 min with arterial blood sampling. The 11 C-HED retention fraction and normalised 11 C-HED activity measured by tissue sampling were compared with those measured by PET. Both the 11 C-HED retention fraction and the normalised 11 C-HED activity measured by PET correlated closely with those measured by tissue sampling (R=0.96027, p 11 C-HED and 123 I-MIBG. Reserpine pretreatment reduced 11 C-HED retention by 50%, but did not reduce 123 I-MIBG retention at 40 min after injection. Non-invasive quantitation of cardiac sympathetic innervation using 11 C-HED PET is feasible and gives reliable estimates of cardiac sympathetic innervation in rabbits. Additionally, although both 11 C-HED and 123 I-MIBG are specific for sympathetic neurons, 11 C-HED may be more specific for intravesicular uptake than 123 I-MIBG in some situations, such as that seen in reserpine pretreatment. (orig.)

  12. In vivo imaging of GABAA receptors using sequential whole-volume iodine-123 iomazenil single-photon emission tomography

    International Nuclear Information System (INIS)

    Busatto, G.F.; Pilowsky, L.S.; Costa, D.C.; Ell, P.J.; Lingford-Hughes, A.; Kerwin, R.W.

    1995-01-01

    Using a brain-dedicated triple-headed single-photon emission tomography (SPET) system, a sequential whole-volume imaging protocol has been devised to evaluate the regional distribution of iodine-123 iomazenil binding to GABA A receptors in the entire brain. The protocol was piloted in eight normal volunteers (seven males and one female; mean age, 24.8±3.9 years). The patterns obtained were largely compatible with the known distribution of GABA A receptors in the brain as reported in autoradiographic studies, with cerebral cortical regions, particularly the occipital and frontal cortices, displaying the highest 123 I-iomazenil uptake. Measures of time to peak uptake and tracer washout rates presented with the same pattern of regional variation, with later times to peak and slower washout rates in cortical regions compared to other brain areas. Semiquantitative analysis of the data using white matter/ventricle regions as reference demonstrated a plateau of specific 123 I-iomazenil binding in neocortical and cerebellar regions from 60-75 min onwards. These data demonstrate the feasibility of sequential, dynamic whole-volume 123 I-iomazenil SPET imaging. The protocol may be particularly useful in the investigation of neuropsychiatric conditions which are likely to involve more than one focus of GABA abnormalities, such as anxiety disorders and schizophrenia. (orig.)

  13. Dynamic low dose I-123-iodophenylpentadecanoic acid metabolic cardiac imaging

    International Nuclear Information System (INIS)

    Murray, G.L.; Magill, H.L.; Schad, N.C.

    1993-01-01

    Recognition of stunned and hibernating myocardium is essential in this era of cardiac revascularization. Positron emission tomography (PET) accurately identifies viability but is costly and unavailable to most patients. Dynamic low dose I-123-iodophenylpentadecanoic acid (IPPA) metabolic cardiac imaging is a potentially cost-effective alternative to PET. Using transmural myocardial biopsies obtained during coronary bypass surgery as the viability gold standard, resting IPPA imaging agreed with 39/43 (91%) biopsies, with a sensitivity for viability of 33/36(92%) and a specificity of 6/7 (86%) in patients with severe ischemic cardiomyopathy. Eighty percent of IPPA viable, infarcted segments improved wall motion postoperatively. Furthermore, when compared to reinjection thallium (SPECT-Tl) scans after myocardial infarction, there was IPPA-Tl concordance in 27/35 (77%)(Kappa=0.536, p=0.0003). Similar to PET, IPPA demonstrated more viability than SPECT-Tl, 26/35 (74%) vs. 18/35 (51%)(p=0.047). Finally, when compared to transvenous endomyocardial biopsy for detecting rejection following cardiac transplantation, IPPA sensitivity for ≥Grade II rejection was 100%, and IPPA screening assessment for the necessity of biopsy could result in a 31% cost-savings. Therefore, IPPA metabolic cardiac imaging is a safe, inexpensive technique with a promising future. (author)

  14. Use of myocardial tomo-scintigraphy by {sup 123}I - MIBG in right ventricle arrhythmia-gen dysplasia; Interet de la tomoscintigraphie myocardique a la {sup 123}I - MIBG dans la dysplasie arrythmogene du ventricule droit

    Energy Technology Data Exchange (ETDEWEB)

    Agostini, D.; Manrique, A.; Darlas, Y. [Service de Medecine Nucleaire, CHU Cote de Nacre, Caen (France); Loiselet, P.; Scanu, P.; Grollier, G.; Potier, J.C. [Service de Cardiologie, CHU Cote de Nacre, Caen (France); Bouvard, G. [Service de Medecine Nucleaire, CHU Cote de Nacre, Caen (France)

    1997-12-31

    The dysfunction of myocardial sympathetic system was implied in occurrence of ventricular arrhythmias in patients with a right ventricle arrhythmia-gen dysplasia (RVAD). The goal of this study is to evaluate the myocardial pre-synaptic adrenergic regional function by using the cardiac tomo-scintigraphy with {sup 123}I - meta-iodo-benzyl-guanidine (MIBG). Fourteen patients (12 M, 2 F, age: 46{+-} 13) in whom the disease`s diagnosis was done on the basis of the parameters of European Task Force (electric, angiographic, histologic), were studied. Six healthy subjects (32 {+-} 12 years) were at the same time studied as control group. Each patient benefited by an at-rest tomo-scintigraphy by {sup 201}Tl to eliminate any hypo-perfusion which could hinder the interpretation of MIBG fixation. A 48 h delay was necessary between the two isotopic examinations. After blocking the thyroid by Lugol fort, an at-rest tomo-scintigraphy by {sup 123}I - MIBG was effected 4 h after the injection IV of 259 MBq of tracer following a classical acquisition of a myocardial tomography with a tracer-adopted collimator (Elscint camera). Global and regional evaluations of the cardiac adrenergic neuronal function were effected by using the cardio-mediastinal ratio (CMR) and the circumferential profile, respectively, for the localization, extension and amplitude of regional adrenergic defects. The CMR is within the normal limits (236 {+-} 39% vs 234 {+-} 14% in healthy subjects). The adrenergic defects are present in 11/14 patients (a reduction of 50% of capture of MIBG as compared with the control group, < average - 2 ET) in the anterior and lateral regions of left ventricle. In conclusion, the tomo-scintigraphy by {sup 123}I - MIBG allows the detecting of presence of a sympathetic dys-innervation of left ventricle in patients afflicted with RVAD

  15. Study of sympathetic nervous function under effort induced ischemia in patients with angina pectoris with I-123 metaiodobenzylguanidine (MIBG) myocardial SPECT images

    International Nuclear Information System (INIS)

    Tanaka, Takeshi; Aizawa, Tadanori; Kato, Kazuzo; Ogasawara, Ken; Sakuma, Toru; Kirigaya, Hajime; Hirosaka, Akira; Igarashi, Masaki

    1990-01-01

    I-123 metaiodobenzylguanidine (MIBG) is a norepinephrine analog, which can be used to study the sympathetic nervous function of the heart. With MIBG myocardial SPECT images sympathetic nervous function under effort induced ischemia were studied in 18 patients with significant coronary artery lesions. In 5 patients with effort induced ischemic region in stress Tl-201 myocardial images rest MIBG images were collected and then exercise stress test was performed. Patients continued exercising for 3 minutes after onset of symptom. Post-stress MIBG images were collected. Definite ischemic region was noted in stress Tl-201 myocardial images, however no differences were noted between rest and post-stress MIBG images. These results suggested that exercise induced ischemia did not enhance release of uptaken MIBG. In 13 patients with significant coronary artery lesions symptom-limited exercise stress test was performed MIBG and Tl-201 were simultaneously injected at onset of symptom and patients continued exercising for an additional one minute. In 6 cases (46%, 6/13) MIBG defects with Tl-201 uptake were noted. These results showed that exercise induced ischemia depressed net MIBG uptake and that sympathetic nervous function (MIBG images) may be more sensitive to ischemic damage than muscle (Tl-201 images). It is suggested that exercise induced ischemia depressed reuptake of norepinephrine at sympathetic nervous endings. MIBG myocardial SPECT images may be useful for evaluating sympathetic nervous function under ischemia. (author)

  16. Relationship between quantitative cardiac neuronal imaging with {sup 123}I-meta-iodobenzylguanidine and hospitalization in patients with heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Parker, Matthew W.; Sood, Nitesh [University of Connecticut, School of Medicine Department of Medicine, Farmington, CT (United States); Hartford Hospital, Division of Cardiology, Hartford, CT (United States); Ahlberg, Alan W. [Hartford Hospital, Division of Cardiology, Hartford, CT (United States); Jacobson, Arnold F. [GE Healthcare, Princeton, NJ (United States); Heller, Gary V. [The Intersocietal Accreditation Commission, Ellicott City, MD (United States); Lundbye, Justin B. [University of Connecticut, School of Medicine Department of Medicine, Farmington, CT (United States); The Hospital of Central Connecticut, Division of Cardiology, New Britain, CT (United States)

    2014-09-15

    Hospitalization in patients with systolic heart failure is associated with morbidity, mortality, and cost. Myocardial sympathetic innervation, imaged by {sup 123}I-meta-iodobenzylguanidine ({sup 123}I-mIBG), has been associated with cardiac events in a recent multicenter study. The present analysis explored the relationship between {sup 123}I-mIBG imaging findings and hospitalization. Source documents from the ADMIRE-HF trial were reviewed to identify hospitalization events in patients with systolic heart failure following cardiac neuronal imaging using {sup 123}I-mIBG. Time to hospitalization was analyzed with the Kaplan-Meier method and compared to the mIBG heart-to-mediastinum (H/M) ratio using multiple-failure Cox regression. During 1.4 years of median follow-up, 362 end-point hospitalizations occurred in 207 of 961 subjects, 79 % of whom had H/M ratio <1.6. Among subjects hospitalized for any cause, 88 % had H/M ratio <1.6 and subjects with H/M ratio <1.6 experienced hospitalization earlier than subjects with higher H/M ratios (log-rank p = 0.003). After adjusting for elevated brain natriuretic peptide (BNP) and time since heart failure diagnosis, a low mIBG H/M ratio was associated with cardiac-related hospitalization (HR 1.48, 95 % CI 1.05 - 2.0; p = 0.02). The mIBG H/M ratio may risk-stratify patients with heart failure for cardiac-related hospitalization, especially when used in conjunction with BNP. Further studies are warranted to examine these relationships. (orig.)

  17. Localization of hepatic metastases by radiolabelled anti-carcino-embryonic antigen antibody and meta-iodobenzylguanidine in a patient with medullary thyroid carcinoma

    International Nuclear Information System (INIS)

    Liewendahl, K.; Vaelimaeki, M.; Taavitsainen, M.

    1993-01-01

    Sonography, computed tomography and magnetic resonance imaging examinations did not detect recurrence or metastases of medullary thyroid carcinoma (MTC) in a patient with a rapidly rising serum calcitonin concentration after total thyroidectomy. Scintigraphy with technetium-99m labelled anti-carcinoembryonic antigen antibody, 99m Tc-colloid and iodine-131 metaiodobenzylguanidine indicated liver metastases. The three scintigrams were to some extent discrepant but from the combined information the diagnosis of hepatic metastases could be established; it was subsequently verified by sonography and aspiration biopsy. This case demonstrates the usefulness of applying nuclear medicine imaging methods for the localization of hepatic MTC metastases. (orig.)

  18. Technical meeting of project counterparts on 'Cyclotron production of Iodine-123'. Report

    International Nuclear Information System (INIS)

    2002-01-01

    Several cyclotron laboratory facilities are very much interested in the production of Iodine-123 for medical applications in view of its optimal physical and chemical properties. Some of these countries have in the past used the solid target technology based on utilization of enriched Tellurium targets and are currently involved in the development of enriched Xenon-124 gas targets to improved radionuclidic purity as required by the needs of modern nuclear medicine. With the purpose of discussing the advances in the later route of production and to foster mutual co-operation among the developing countries interested in this technology, a meeting was convened with the participation of scientists from Argentina, Brazil, Iran, Korea and Syria. A scientist from the United States was also invited as an expert to provide advise on particular aspects of the technology. This publication contains as an annex technical reports from the participating institutions. All of these reports have been separately indexed and provided with abstracts

  19. Meta-iodobenzylguanidine (MIBG) and staging in pediatric oncology

    International Nuclear Information System (INIS)

    Nagel, M.; Mende, T.

    2002-01-01

    Aim: MIBG is primarily used in children to image neuroblastoma. Other APUD cell line tumors demonstrate uptake of the tracer less frequently. Adrenal medullary hyperplasia may also be imaged. Actual we have estimate the significance of the receptor scintigraphy with meta-iodobenzylguanidine in the former patient group. Material and Methods: We have retrospectively analysed the data of 86 investigations from 30 patients over a period from 1995, June to 2002, January. The age ranged from 2,4 month to 17,6 years. Respectively we have applied a total dose ranged from 0,75 mCi to 6,5 mCi 123-iodine, adapted at body weight. All of the investigations were made at the double-head camera Multispect II (Siemens). The image analysis was assessed as positive when the investigations both at 4 and 24 hours post injection could reliable demonstrate a pathological tracer uptake, SPECT imaging included. Results: From the 30 patients 21 were assessed as positive for MIBG-receptor imaging. 18 patients were suspicious to have a neuroblastoma. The other three were investigated for pheochromocytoma, other neuroendocine tumor than neuroblastoma and elevated tumor marker levels. Interestingly only one patient was false positive: the suspected metastasis in the liver after a neuroblastoma therapy 10 years before is emerged as focal nodular hyperplasia of the liver. The other nine patients having minor symptoms for any neuroblastoma-like changes such as nephroblastoma, regional tumor of the chest, unclear blood changes had no positive image results. Therefore we have to determine the sensitivity and specificity to 100% resp. 90% at the first investigation. The results with regard to the origin of the first investigation are presented. Conclusion: The nuclear medicine diagnostic in pediatric oncology with meta-iodobezylguanidine allows the precise staging in the special patient group with clinical suspicious for neuroblastoma. Recommendable is the SPECT-technique and iterative reconstruction

  20. Multicurie, transportable, integrally shielded 123Xe → 123I generator and processing system for high-purity iodine-123 production

    International Nuclear Information System (INIS)

    Lagunas-Solar, M.C.; Thibeau, H.L.; Goodart, C.E.; Little, F.E.; Navarro, N.J.; Hartnett, D.E.

    1985-01-01

    An integrally shielded 123 Xe → 123 I generator system has been designed and tested under production conditions for its suitability as a multicurie handling device from which to produce radiopharmaceutical-quality high-purity no-carrier-added (NCA) 123 I. The 123 Xe → 123 I generator system is expected to provide an alternative to current techniques and to increase the availability and reliability of high-purity 123 I made via the 127 I(p,5n) 123 Xe → 123 I nuclear reaction. The generator system is based on the Crocker Nuclear Laboratory's continuous-flow production system which has been operating since 1974 for the multicurie production of 123 I. The generator system, which consists of an integrally shielded xenon trap and separate loading and processing apparatuses, is simple and reliable to operate, can be adapted to computerized control, and provides a safe working environment for the repeated handling of multicurie amounts of Xe-I radioactivities

  1. Comparison of somatostatin analogue and metaiodobenzylguanidine scintigraphy for the detection of carcinoid tumours

    International Nuclear Information System (INIS)

    Nocaudie-Calzada, M.; Huglo, D.; Carnaille, B.; Proye, C.; Marchandise, X.

    1996-01-01

    The purpose of this prospective study was to compare the ability of radiolabelled somatostatin analogue (RSA) and metaiodobenzylguanidine (MIBG) scintigraphy to display carcinoid tumours. Forty patients were studied after radiological assessment based on clinical symptomatology. These patients had radiologically demonstrated tumours (n=28), resected tumours discovered to be of the carcinoid type (n=5) or clinically and biologically suspected carcinoid tumours (n=7). They underwent indium-111 DTPA-pentetreotide or iodine-123-Tyr-3-octreotide and 131 I-MIBG scintigraphy. The results were compared with those of complementary surgical or morphological examinations and analysed according to the site of the tumour and the symptomatology. In the case of 31 patients with a total of 55 tumoral sites, the sensitivity of the initial radiological assessment, of RSA and of MIBG was 96%, 86% and 64%, respectively, for the detection of at least one tumour per patient, but 51%, 85% and 51%, respectively, for the total number of sites. No site was detected solely by MIBG. The concordance between RSA and MIBG was better when all sites were considered (kappa index+0.44) than for only extrahepatic abdominal tumoral sites (kappa index+0.095). Abdominal, thoracic or bone marrow tumours were more easily detected with RSA than with MIBG. Hepatic invasion (21 cases) was more easily detected by radiology (sensitivity 100%) than by RSA and MIBG, both of which displayed a sensitivity of 80%, but with differences in uptake intensity. Tumour detection using MIBG was more significantly linked with flush (P 0.10). In the assessment of carcinoid tumours, RSA scintigraphy should be carried out initially (just after hepatic ultrasonography) and supplemented by MIBG, as comparison of the studies serves to guide therapeutic options and might be valuable for prognosis. (orig.). With 2 figs., 3 tabs

  2. Imaging active lymphocytic infiltration in coeliac disease with iodine-123-interleukin-2 and the response to diet

    International Nuclear Information System (INIS)

    Signore, A.; Chianelli, M.; Annovazzi, A.; Rossi, M.; Greco, M.; Ronga, G.; Picarelli, A.; Maiuri, L.; Britton, K.E.

    2000-01-01

    Coeliac disease is diagnosed by the presence of specific antibodies and a jejunal biopsy showing mucosal atrophy and mononuclear cell infiltration. Mucosal cell-mediated immune response is considered the central event in the pathogenesis of coeliac disease, and untreated coeliac patients show specific features of T-cell activation in the small intestine. Here we describe the use of iodine-123-interleukin-2 scintigraphy in coeliac patients as a non-invasive tool for detection of lymphocytic infiltration in the small bowel and its use for therapy follow-up, and we demonstrate the specificity of binding of labelled-IL2 to activated lymphocytes by ex-vivo autoradiography of jejunal biopsies. 123 I-IL2 was administered i.v. [74 MBq (2 mCi)], and gamma camera images were acquired after 1 h. Ten patients were studied with 123 I-IL2 scintigraphy at diagnosis and seven were also investigated after 12-19 months of gluten-free diet. Results were expressed as target-to-background radioactivity ratios in six different bowel regions before and after the diet. At the time of diagnosis all patients showed a significantly higher bowel uptake of 123 I-IL2 than normal subjects (P 2 =0.66; P=0.008). Autoradiography of jejunal biopsies confirmed that labelled-IL2 only binds to activated T-lymphocytes infiltrating the gut mucosa. After 1 year of the diet, bowel uptake of 123 I-IL2 significantly decreased in five out of six regions (P 123 I-IL2 scintigraphy is a sensitive non-invasive technique for assessing in vivo the presence of activated mononuclear cells in the bowel of patients affected by coeliac disease. Unlike jejunal biopsy, this method provides information from the whole intestine and gives a non-invasive measure of the effectiveness of the gluten-free diet. (orig.)

  3. 123I research and production at Brookhaven

    International Nuclear Information System (INIS)

    Mausner, L.F.; Srivastava, S.C.; Mirzadeh, S.; Meinken, G.E.; Prach, T.

    1985-01-01

    The procedures for preparing high purity 123 I at the BLIP using the 127 I(p,5n) 123 Xe reaction on an NaI target are described. The activity is supplied in a glass ampoule with anhydrous 123 I deposited on the interior walls, allowing maximum flexibility in subsequent iodinations. Preliminary experience with a continuous flow target is also described. The results of a series of measurements of specific activity by neutron activation, x-ray fluorescence, uv absorption, and wet chemistry generally showed no detectable carrier. HPLC methods to analyse the chemical form of radioiodine and to characterize various iodinated radiopharmaceuticals have been developed. These methods provide higher sensitivity, speed and resolution than commonly used techniques. 19 refs., 6 figs., 2 tabs

  4. Effect of chronic douching with polyvinylpyrrolidone-iodine on iodine absorption and thyroid function

    International Nuclear Information System (INIS)

    Safran, M.; Braverman, L.E.

    1982-01-01

    Daily vaginal douching with polyvinylpyrrolidone-iodine in 12 euthyroid volunteers for 14 days resulted in a significant increase in serum total iodine concentration and urine iodine excretion. The increase in serum total iodine was associated with a marked decrease in 24-hour 123 I uptake by the thyroid and a small but significant increase in serum thyrotropin (TSH) concentration. However, values for serum TSH never rose above the normal range. No significant changes in serum thyroxine (T4), free T4 index (FTI), or triiodothyronine concentrations were observed, although serum T4 and FTI did decrease slightly during treatment. The findings suggest that iodine is absorbed across the vaginal mucosa and that the subsequent increase in serum total iodine does induce subtle increases in serum TSH concentration. There was no evidence, however, of overt hypothyroidism in these euthyroid women

  5. 131I Metaiodobenzylguanidine scintigraphy

    International Nuclear Information System (INIS)

    Izumi, Motomori; Morimoto, Isao; Yamashita, Shunichi; Hirayu, Hideshi; Nagataki, Shigenobu

    1988-01-01

    A newly developed radiopharmaceutical agent, 131 I-metaiodobenzylguanidine ( 131 I-MIBG) has been reported to be very useful for locating pheochromocytoma and to be specific for pheochromocytoma and safe for humans. The first 131 I-MIBG scintiscanning in Japan which has been carried out in our clinic and the analysis of clinical experience of 131 I-MIBG scanning in Japan are presented

  6. Optimal iodine staining of cardiac tissue for X-ray computed tomography.

    Science.gov (United States)

    Butters, Timothy D; Castro, Simon J; Lowe, Tristan; Zhang, Yanmin; Lei, Ming; Withers, Philip J; Zhang, Henggui

    2014-01-01

    X-ray computed tomography (XCT) has been shown to be an effective imaging technique for a variety of materials. Due to the relatively low differential attenuation of X-rays in biological tissue, a high density contrast agent is often required to obtain optimal contrast. The contrast agent, iodine potassium iodide ([Formula: see text]), has been used in several biological studies to augment the use of XCT scanning. Recently I2KI was used in XCT scans of animal hearts to study cardiac structure and to generate 3D anatomical computer models. However, to date there has been no thorough study into the optimal use of I2KI as a contrast agent in cardiac muscle with respect to the staining times required, which has been shown to impact significantly upon the quality of results. In this study we address this issue by systematically scanning samples at various stages of the staining process. To achieve this, mouse hearts were stained for up to 58 hours and scanned at regular intervals of 6-7 hours throughout this process. Optimal staining was found to depend upon the thickness of the tissue; a simple empirical exponential relationship was derived to allow calculation of the required staining time for cardiac samples of an arbitrary size.

  7. Frequency and characteristics of extremely low accumulation of 123I-metaiodobenzylguanidine (MIBG) in patients with and without cardiovascular diseases

    International Nuclear Information System (INIS)

    Sakata, Kazuyuki; Iida, Kei; Motiduki, Nao; Nakaya, Yoshihiro

    2008-01-01

    Very low accumulation of 123 I-metaiodobenzylguanidine (LoMIBG) in the human heart has been reported. This study assessed the frequency and characteristics of LoMIBG in the human heart. A total of 2212 patients (male/female ratio 1442/770, mean age 64±12 years) who underwent MIBG imaging were included. LoMIBG was defined as an initial heart-to-mediastinum (H/M) ratio of less than 1.4. Of the 114 patients with LoMIBG, 2 patients were excluded because of taking imipramine. Patients with LoMIBG were older than those without LoMIBG (P<0.0001). The main diagnosis and the number of patients with each disease were as follows: 28 of 410 coronary artery disease patients, 13 of 371 vasospastic angina patients, 3 of 86 various arrhythmias patients, 4 of 23 valvular heart disease patients, 9 of 101 dilated cardiomyopathy patients, 13 of 512 essential hypertension patients, 2 of 20 hypertrophic cardiomyopathy patients, 24 of 511 subjects without any definite disease (control), and 16 of 176 patients with miscellaneous diseases. When compared with patients without LoMIBG in each cardiovascular disease, LoMIBG patients had left ventricular function and frequency similar to critically ill patients. In the control group, the subjects with LoMIBG were significantly older (P<0.0001) and had significantly higher HF (P<0.03) and lower LF/HF (P<0.001) than those without LoMIBG. In addition, the incidence of LoMIBG was significantly elevated in the elderly (P<0.002). LoMIBG occurred in patients both with various diseases and without obvious diseases. Aging may be one of the mechanisms contributing to LoMIBG, especially in patients without obvious diseases. (author)

  8. In vivo imaging of GABA{sub A} receptors using sequential whole-volume iodine-123 iomazenil single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Busatto, G.F. [Dept. of Psychological Medicine, Inst. of Psychiatry, London (United Kingdom); Pilowsky, L.S. [Dept. of Psychological Medicine, Inst. of Psychiatry, London (United Kingdom); Costa, D.C. [Inst. of Nuclear Medicine, University Coll. and Middlesex School of Medicine, London (United Kingdom); Ell, P.J. [Inst. of Nuclear Medicine, University Coll. and Middlesex School of Medicine, London (United Kingdom); Lingford-Hughes, A. [Dept. of Psychological Medicine, Inst. of Psychiatry, London (United Kingdom); Kerwin, R.W. [Dept. of Psychological Medicine, Inst. of Psychiatry, London (United Kingdom)

    1995-01-01

    Using a brain-dedicated triple-headed single-photon emission tomography (SPET) system, a sequential whole-volume imaging protocol has been devised to evaluate the regional distribution of iodine-123 iomazenil binding to GABA{sub A} receptors in the entire brain. The protocol was piloted in eight normal volunteers (seven males and one female; mean age, 24.8{+-}3.9 years). The patterns obtained were largely compatible with the known distribution of GABA{sub A} receptors in the brain as reported in autoradiographic studies, with cerebral cortical regions, particularly the occipital and frontal cortices, displaying the highest {sup 123}I-iomazenil uptake. Measures of time to peak uptake and tracer washout rates presented with the same pattern of regional variation, with later times to peak and slower washout rates in cortical regions compared to other brain areas. Semiquantitative analysis of the data using white matter/ventricle regions as reference demonstrated a plateau of specific {sup 123}I-iomazenil binding in neocortical and cerebellar regions from 60-75 min onwards. These data demonstrate the feasibility of sequential, dynamic whole-volume {sup 123}I-iomazenil SPET imaging. The protocol may be particularly useful in the investigation of neuropsychiatric conditions which are likely to involve more than one focus of GABA abnormalities, such as anxiety disorders and schizophrenia. (orig.)

  9. Synthesis of iodine-123 labelled analogues of the partial agonist (S)-and (R)-bretazenil for the study of CNS benzodiazepine receptors using SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Katsifis, Andrew; Mattner, Filomena; McPhee, Meredith; Kassiou, Michael; Najdovski, Ljubco; Dikic, Branko [Australian Nuclear Science and Technology Organisation, Radiopharmaceutical Div., Menai, Sydney, NSW (Australia)

    1996-09-01

    The (S) and (R)-[{sup 123}I]iodinated analogues of the benzodiazepine receptor partial agonist bretazenil have been synthesized for study of the central benzodiazepine receptor using SPECT, (S)- and (R)-[{sup 123}I]iodobretazenil were prepared from the appropriate tin precursors by electrophilic iododestannylation with Na[{sup 123}I] in the presence of Chloramine-T. The products were purified by semi-preparative reverse-phase HPLC with radiochemical yields of 80% in a total synthesis time of 50 minutes. The specific activity was determined to be greater than 2500 Ci/mmol. The radiochemical and chemical purity assessed by radio-TLC and HPLC were found to be 98%. The enantiomeric purity of the (S) and (R) isomers were greater than 97% as assessed by analytical chiral HPLC analysis. (author).

  10. Synthesis of 123I-16 iodo estradiol

    International Nuclear Information System (INIS)

    Therain, F.; Gros, J.; Souchu, A.

    1982-01-01

    16α iodo estradiol has been demonstrated to have as good an affinity as estradiol for estrogen-receptors and, labeled with iodine 123, may provide a good scanning agent fot visualisation of tissues containing estrogen-repectors, especially mammary tumors. 123 I-16α iodo estradiol has been synthesized by an halogen exchange of 16ν bromo estradiol according to the procedure described by Hochberg for 125 I-16α iodo estradiol labeling. Radiochemical yields are much lower than with iodine 125 (1 to 30%) and extremely variable. Specific activity range from 1,000 to 2,000 Ci/mmole [fr

  11. Initial experience with single-photon emission tomography using iodine-123-labelled 2β-carbomethoxy-3β(4-iodophnyl)tropane in human brain

    International Nuclear Information System (INIS)

    Kuikka, J.T.; Bergstroem, K.A.; Vanninen, E.; Laulumaa, V.; Hartikainen, P.; Laensimies, E.

    1993-01-01

    The iodinated cocaine analogue 2β-carbomethoxy-3β-(4-iodophenyl)tropane ([ 123 I]β-CIT), a new dopamine transporter, was preliminarily tested in human brain. Two normal volunteers and two patients with Parkinson's disease were imaged with a high-resolution single-photon emission tomography scanner. The specific binding of [ 123 I]β-CIT in the basal ganglia and thalamus was high in normal volunteers. In addition, there was relatively intense uptake in the medial prefrontal area. Patients with Parkinson's disease who were older than controls showed significantly lower specific binding in the basal ganglia and thalamus and no uptake in the medial prefrontal cortex. This decrease in the dopamine transporter may be age related. (orig.)

  12. Initial experience with single-photon emission tomography using iodine-123-labelled 2[beta]-carbomethoxy-3[beta](4-iodophnyl)tropane in human brain

    Energy Technology Data Exchange (ETDEWEB)

    Kuikka, J T [Kuopio Univ. Hospital (Finland). Dept. of Clinical Physiology; Bergstroem, K A [Kuopio Univ. Hospital (Finland). Dept. of Clinical Physiology; Vanninen, E [Kuopio Univ. Hospital (Finland). Dept. of Clinical Physiology; Laulumaa, V [Kuopio Univ. Hospital (Finland). Dept. of Neurology; Hartikainen, P [Kuopio Univ. Hospital (Finland). Dept. of Neurology; Laensimies, E [Kuopio Univ. Hospital (Finland). Dept. of Clinical Physiology

    1993-09-01

    The iodinated cocaine analogue 2[beta]-carbomethoxy-3[beta]-(4-iodophenyl)tropane ([sup 123]I[beta]-CIT), a new dopamine transporter, was preliminarily tested in human brain. Two normal volunteers and two patients with Parkinson's disease were imaged with a high-resolution single-photon emission tomography scanner. The specific binding of [sup 123]I[beta]-CIT in the basal ganglia and thalamus was high in normal volunteers. In addition, there was relatively intense uptake in the medial prefrontal area. Patients with Parkinson's disease who were older than controls showed significantly lower specific binding in the basal ganglia and thalamus and no uptake in the medial prefrontal cortex. This decrease in the dopamine transporter may be age related. (orig.)

  13. Estimation of 123I-metaiodobenzylguanidine lung uptake in heart and lung diseases. With reference to lung uptake ratio and decrease of lung uptake

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Tanaka, Masao; Yazaki, Yoshikazu; Kitabayashi, Hiroshi; Koizumi, Tomonori; Sekiguchi, Morie; Gomi, Tsutomu; Yano, Kesato; Itoh, Atsuko.

    1997-01-01

    123 I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy was performed in 64 patients with heart and lung diseases. Distribution of MIBG in the chest was evaluated by planar images, using counts ratios of the heart to the mediastinum (H/M) and the unilateral lung to the mediastinum (Lu/M). Most of patients with heart diseases showed obvious lung uptake of MIBG. The ratios of H/M were 1.75±0.20 in the group without heart failure and 1.55±0.19 in the group with heart failure. The ratios of Lu/M in the right and left lung were 1.56±0.16 and 1.28±0.16 in the group without heart failure. And those were 1.45±0.16 and 1.19±0.15 in the group with heart failure. But 3 patients complicated with chronic pulmonary emphysema and one patient with interstitial pneumonia due to dermatomyositis showed markedly decreased lung uptake. The ratios of Lu/M in the right and left lung of these patients were 1.20, 1.17; 1.17, 1.13; 1.01, 0.97 and 1.27, 0.94, respectively. These results suggest that the lung uptake of MIBG may reflect the state of pulmonary endothelial cell function in clinical situations, considering that it has been demonstrated that MIBG may be useful as a marker of pulmonary endothelial cell function in the isolated rat lung. (author)

  14. Magnesium sulphate and (123)I-MIBG in pheochromocytoma: Two useful techniques for a complicated disease.

    Science.gov (United States)

    Vendrell, M; Martín, N; Tejedor, A; Ortiz, J T; Muxí, À; Taurà, P

    2016-01-01

    Pheochromocytoma is a tumour of the chromaffin tissue. It may, through catecholamine release, have deleterious effects on myocardial structure. A 48-year-old woman with a history of hypertension and type II diabetes mellitus (ASA II) was diagnosed of pheochromocytoma-induced myocarditis, which caused severe cardiogenic shock, with an ejection fraction of 20%. Extreme blood pressure swings required aggressive therapy with vasoactive drugs (norepinephrine and dopamine) and an intra-aortic balloon pump, despite which severe haemodynamic instability persisted. Finally, the use of magnesium sulphate allowed for cardiovascular stabilization and weaning off vasoactive drugs prior to surgery. (123)I-metaiodobenzylguanidine scintigraphy helps not only to functionally confirm tumour tissue, but also to assess severity and prognosis of cardiac failure. Prognosis of pheochromocytoma-induced heart failure can be very poor. The use of these two well-known and relatively simple 'tools' for treatment and prognosis is a helpful option to keep in mind. Copyright © 2014 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. I131-meta-iodobenzylguanidine in the diagnosis and treatment of neural crest tumours

    International Nuclear Information System (INIS)

    Hoefnagel, C.A.; Hartog Jager, F.C.A. den; Taal, B.G.; Engelsman, E.; Kraker, J. de; Voute, P.A.

    1988-01-01

    Iodine-131-meta-iodobenzylguanidine (I-131-MIBG) was used for scintigraphic detection and therapy of neural crest tumours. The methodology of both techniques is described. Based upon experience with I-131-MIBG-scintigraphy in 170 patients with neural crest tumours, of whom 46 received multiple therapeutic doses of I-131-MIBG, and upon the cumulative reports in the literature, the role of I-131-MIBG in diagnosis and treatment of each of these diseases is indicated. I-131-MIBG-scintigraphy is one of the most sensitive and specific techniques for the diagnosis, staging and follow-up of phaeochromocytoma and neuroblastoma and I-131-MIBG-therapy may induce remission in a number of these patients. In carcinoid and medullary thyroid carcinoma the diagnostic sensitivity is less; however, once the diagnosis has been made, it is useful to establish that the tumour concentrates I-131-MIBG, to see if the patients at some point in time may be amenable to I-131-MIBG-therapy

  16. Synthesis of [123I]iodine labelled imidazo[1,2-b] pyridazines as potential probes for the study of peripheral benzodiazepine receptors using SPECT

    International Nuclear Information System (INIS)

    Katsifis, A.; Mattner, F.; Dikic, B.; Barlin, G.

    2004-01-01

    The pyridazines 3-acetamidomethyl-6-chloro-2-(4'-iodophenyl)imidazo[1,2-b]pyridazine 1 (IC 50 = 1.6 nM) and 3-benzamidomethyl-6-iodo-2-(4'-t-butylphenyl)imidazo[1,2-b] pyridazine 2 (IC 50 = 4.2 nM), are high affinity and selective ligands for the peripheral benzodiazepine receptors (PBR) compared to the central benzodiazepine counterparts. The [ 123 I]1 and [ 123 I]2 labelled analogues of these compounds were subsequently synthesised for the potential study of the PBR in vivo using SPECT. Radioiodination of [ 123 I]1 was achieved by iododestannylation of the corresponding tributyl tin precursor with Na[ 123 I] in the presence of peracetic acid or chloramine-T and the product isolated by C-18 RP HPLC. Radioiodination of [ 123 I]2 was achieved by copper assisted bromine [ 123 I]iodine exchange of the corresponding bromo precursor in the presence of acetic acid and sodium bisulfate as reducing agent at 200 C. Purification of the crude products were achieved by semi-preparative C-18 RP HPLC to give the products in radiochemical yields > 90%. The products were obtained in > 97% chemical and radiochemical purity and with specific activities > 180 GBq/μmol. (orig.)

  17. 123-iodine heptadecanoic acid (HDA) cardiac metabolism of inactive sportsmen with nuclear cardiology, impacted into complex cardiological studies

    International Nuclear Information System (INIS)

    Horvath, Mihaly; Pszota, Agnes; Karman, Miklos; Boeszoermenyi, Ernoe

    1987-01-01

    8 inactive sportsmen and 8 heavy physical workers with similar mean age (36 years) and mean body surface (2 m 2 ) were analysed functionally and metabolically for myocardial hypertrophy. 123 I-heptadecanoic acid (HDA) scintigraphy and kinetics were carried out with methods of Feinendegen and Dudczak and using Hungarian gamma-camera. In both groups good correlation was found between the myocardial uptake of 123 I-HDA and 201 Tl. Regional alterations of myocardial perfusion during ergometric load were analyzed and compared to alterations of the ECG and echo. (author) 24 refs.; 7 figs

  18. Assessment of central chemosensitivity and cardiac sympathetic nerve activity using I-123 MIBG imaging in central sleep apnea syndrome in patients with dilated cardiomyopathy

    International Nuclear Information System (INIS)

    Meguro, Kentaro; Nagai, Ryozo; Toyama, Takuji; Adachi, Hitoshi; Ohshima, Shigeru; Taniguchi, Koichi

    2007-01-01

    Iodine-123 m-iodobenzylguanidine (MIBG) imaging has been used to study cardiac sympathetic function in various cardiac diseases. Central sleep apnea syndrome (CSAS) occurs frequently in patients with chronic heart failure (CHF) and is reported to be associated with a poor prognosis. One of the mechanisms of its poor prognosis may be related to impaired cardiac sympathetic activity. However, the relationship between chemosensitivity to carbon dioxide, which is reported to correlate with the severity of CSAS, and cardiac sympathetic activity has not been investigated. Therefore, this study was undertaken to assess cardiac sympathetic function and chemosensitivity to carbon dioxide in CHF patients. The oxygen desaturation index (ODI) was evaluated in 21 patients with dilated cardiomyopathy (male/female: 19/2, left ventricular ejection fraction (LVEF) 5 times/h underwent polysomnography. Patients with an apnea hypopnea index >15/h but without evidence of obstructive apnea were defined as having CSAS. Early (15 min) and delayed (4 hr) planar MIBG images were obtained from these patients. The mean counts in the whole heart and the mediastinum were obtained. The heart-to-mediastinum count ratio of the delayed image (H/M) and the corrected myocardial washout rate (WR) were also calculated. The central chemoreflex was assessed with the rebreathing method using a hypercapnic gas mixture (7% CO 2 and 93% O 2 ). Ten of the 21 patients had CSAS. The H/M ratio was similar in patients both with and without CSAS (1.57±0.18 vs. 1.59±0.14, p=0.82). However, the WR was higher in patients with CSAS than in patients without CSAS (40±8% vs. 30±12%, p<0.05). ODI significantly correlated with central chemosensitivity to carbon dioxide. Moreover, there was a highly significant correlation between WR and central chemosensitivity (r=0.65, p<0.05). However, there was no correlation between ODI and the WR (r=0.36, p=0.11). Cardiac sympathetic nerve activity in patients with CHF and CSAS is

  19. Indocyanine green labeled with /sup 123/I for dynamic studies of the hepato-biliary system. [/sup 131/I, /sup 125/I

    Energy Technology Data Exchange (ETDEWEB)

    Lambrecht, R.M.; Ansari, A.N.; Wolf, A.P.; Atkins, H.L.

    1975-01-01

    This report summarizes the results to develop an iodine-123 labeled agent for dynamic studies of the hepato-biliary system. Iodine-123 is an ideal nuclide for radiopharmaceuticals, because of its short half-life (T/sub /sup 1///sub 2// = 13.3 hr); its decay with a high abundance (83%) of 159 keV photons; and the reduced patient radiation exposure (a factor of 100 less than iodine-131). Indocyanine green, a tricarbanocyanine dye, was introduced by Heseltine and co-workers in 1956, has several characteristics which suggested that iodine-123 labeled ICG might be potentially useful for hepatic functional evaluation. The plasma clearance and biliary excretion kinetics of /sup 123/I-ICG (in dogs) will be compared to /sup 131/I-rose bengal and bromosulphalein labeled with iodine-125.

  20. Potential diagnostic value of regional myocardial adrenergic imaging using {sup 123}I-MIBG SPECT to identify patients with Lewy body diseases

    Energy Technology Data Exchange (ETDEWEB)

    Lebasnier, Adrien; Peyronnet, Damien; Bouvard, Gerard [University Hospital Center of Caen, Department of Nuclear Medicine, Caen (France); Lamotte, Guillaume; Defer, Gilles [University Hospital Center of Caen, Department of Neurology, Caen (France); Manrique, Alain [University Hospital Center of Caen, Department of Nuclear Medicine, Caen (France); Cyceron PET Centre, Caen (France); Normandie Universite, Caen (France); Agostini, Denis [University Hospital Center of Caen, Department of Nuclear Medicine, Caen (France); Normandie Universite, Caen (France)

    2015-01-28

    The aim of this study was to determine the potential diagnostic value of regional myocardial adrenergic {sup 123}I-metaiodobenzylguanidine (MIBG) single photon emission computed tomography (SPECT) imaging to identify patients with Lewy body diseases (LBD+). Sixty-four consecutive patients who underwent cardiac {sup 123}I-MIBG SPECT to differentiate LBD+, including Parkinson's disease (PD) and dementia with Lewy bodies (DLB), from patients without LBD (LBD-) were retrospectively reviewed. A neurologist expert in memory disorders determined the final clinical diagnosis by using international clinical diagnostic criteria. Planar [heart to mediastinum ratio (HMR)] and {sup 123}I-MIBG SPECT[innervation defect score (IDS)] using the 17-segment left ventricular model (five-point scale) were obtained 4 h after the injection of {sup 123}I-MIBG on a low-energy high-resolution (LEHR) collimator. Receiver-operating characteristic (ROC) analysis was performed to determine the optimal HMR and IDS cut-off values to discriminate LBD+ from LBD-. Of the 64 patients, 45 (70 %) were diagnosed LBD+ (DLB, n = 27; PD, n = 18) and 19 were diagnosed LBD- (5 other dementias, 14 other parkinsonisms). The HMR and IDS of LBD+ were significantly different from those of LBD- (1.30 ± 0.21 vs 1.65 ± 0.26, p < 0.001; 39 ± 28 vs 8 ± 16, p = 0.001). The optimal HMR and IDS cut-off values to discriminate LBD+ (n = 45) from LBD- (n = 19) were 1.47 and 6/68, providing a sensitivity and specificity of 82.2 and 84.2 % and 86.7 and 73.7 %, respectively. Regional myocardial adrenergic {sup 123}I-MIBG imaging SPECT has a potential diagnostic value to identify LBD+. (orig.)

  1. 123 I production using CV-28 cyclotron from IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Mestnik, S.A.C.; Mengatti, J.; Nieto, W.; Yanagawa, S.I.; Sumiya, L.C.A.; Silva, C.P.G.; Osso Junior, J.A.

    1992-01-01

    The main conditions for iodine 123 production by 124 Te (p,2 n) 123 I reaction were presented, using the cyclotron CV-28 at IPEN-CNEN/SP, with protons of E max = 24 MeV. Two types of targets (Te O 2 and Te O 2 + 2% Al 2 O 3 ) and the influence of Al 2 O 3 in iodine release were studied. After the selection, the 124 Te O 2 (96,2%) target, was melted in platinum support and irradiated with proton current until 12 mu A. The separation of 123 I was made by dry distillation, using induction furnace and O 2 atmosphere. (C.G.C.)

  2. [Complete hormonal and metabolic response after iodine-131 metaiodobenzylguanidine treatment in a patient diagnosed of malignant pheochromocytoma].

    Science.gov (United States)

    García Alonso, M P; Balsa Bretón, M A; Paniagua Correa, C; Castillejos Rodríguez, L; Rodríguez Pelayo, E; Mendoza Paulini, A; Ortega Valle, A; Penín González, J

    2013-01-01

    Radiolabeled metaiodobenzylguanidine is an analogue of norepinephrine used to localize tumors that express the neurohormone transporters, specifically those derived from the neural crest having a neuroendocrine origin. It is also used to treat non-surgical metastases derived from them. A review of the literature revealed symptomatic improvements associated to a decrease in hormone levels in a significant percentage of patients after (131)I-MIBG treatment. However, complete tumor remission has been described only in very few cases and hardly ever when bone metastases exist. We present a case of a patient diagnosed of malignant pheochromocytoma who achieved complete hormonal and metabolic response after (131)I-MIBG treatment (600 mCi) in spite of the presence of bone metastases. Copyright © 2012 Elsevier España, S.L. and SEMNIM. All rights reserved.

  3. Synthesis of [{sup 123}I]iodine labelled imidazo[1,2-b] pyridazines as potential probes for the study of peripheral benzodiazepine receptors using SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Katsifis, A.; Mattner, F.; Dikic, B. [Radiopharmaceuticals Div. ANSTO, Menai, NSW (Australia); Barlin, G. [Div. of Neurosciences, John Curtin School of Medical Research, Australian National Univ., Canberra (Australia)

    2004-07-01

    The pyridazines 3-acetamidomethyl-6-chloro-2-(4'-iodophenyl)imidazo[1,2-b]pyridazine 1 (IC{sub 50} = 1.6 nM) and 3-benzamidomethyl-6-iodo-2-(4'-t-butylphenyl)imidazo[1,2-b] pyridazine 2 (IC{sub 50} = 4.2 nM), are high affinity and selective ligands for the peripheral benzodiazepine receptors (PBR) compared to the central benzodiazepine counterparts. The [{sup 123}I]1 and [{sup 123}I]2 labelled analogues of these compounds were subsequently synthesised for the potential study of the PBR in vivo using SPECT. Radioiodination of [{sup 123}I]1 was achieved by iododestannylation of the corresponding tributyl tin precursor with Na[{sup 123}I] in the presence of peracetic acid or chloramine-T and the product isolated by C-18 RP HPLC. Radioiodination of [{sup 123}I]2 was achieved by copper assisted bromine [{sup 123}I]iodine exchange of the corresponding bromo precursor in the presence of acetic acid and sodium bisulfate as reducing agent at 200 C. Purification of the crude products were achieved by semi-preparative C-18 RP HPLC to give the products in radiochemical yields > 90%. The products were obtained in > 97% chemical and radiochemical purity and with specific activities > 180 GBq/{mu}mol. (orig.)

  4. Clinical evaluation of 123I-MIBG for assessment of sympathetic nervous system in the heart

    International Nuclear Information System (INIS)

    Hirosawa, Koushitiro; Tanaka, Takeshi; Hisada, Kin-ichi; Bunko, Hisashi.

    1991-01-01

    Multi-center clinical trial of 123 I-metaiodobenzylguanidine ( 123 I-MIBG) was carried out to assess its utility as a scintigraphic imaging agent reflecting sympathetic neuronal function in cardiovascular field. Studies were performed on patients with heart diseases of three categories, myocardial infarction, angina pectoris and cardiomyopathy. Scintigraphic images, reflecting sympathetic neuronal function, were obtained with 123 I-MIBG from all of those categories of patients and the efficacy of the imaging was revealed in 781 (95.0%) out of 822 patients. In some patients abnormality was suggested in sympathetic neuronal function with 123 I-MIBG imaging, in spite of normal findings with myocardial perfusion scintigraphy by 201 TlCl. In all 981 patients studied with 123 I-MIBG, there have been no severe adverse reactions, except complaints of burning on injection site of the agent or nausea, ect. from 4 patients. We conclude that 123 I-MIBG imaging is one of the effective tools for diagnostic use reflecting topical sympathetic neuronal function in the heart, judging from its safety and efficacy. (author)

  5. Effect of Atorvastatin vs. Rosuvastatin on cardiac sympathetic nerve activity in non-diabetic patients with dilated cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Tsutamoto, Takayoshi; Ibe, Kunihiro [Toyosato Hospital, Toyosato, Shiga (Japan); Sakai, Hiroshi; Yamaji, Masayuki; Kawahara, Chiho; Nakae, Ichiro; Fujii, Masanori; Yamamoto, Takashi; Horie, Minoru [Shiga Univ. of Medical Science, Faculty of Medicine, Otsu, Shiga (Japan)

    2011-08-15

    Effects of statin therapy on cardiac sympathetic nerve activity in patients with chronic heart failure (CHF) have not previously been evaluated. To compare the effects of lipophilic atorvastatin and hydrophilic rosuvastatin on cardiac sympathetic nerve activity in CHF patients with dilated cardiomyopathy (DCM), 63 stable outpatients with DCM, who were already receiving standard therapy for CHF, were randomized to atorvastatin (n=32) or rosuvastatin (n=31). We evaluated cardiac sympathetic nerve activity by cardiac {sup 123}I-metaiodobenzylguanidine (MIBG) scintigraphy, hemodynamic parameters and neurohumoral factors before and after 6 months of treatment. There were no differences in the baseline characteristics of the 2 groups. In the rosuvastatin group, there were no changes in MIBG parameters, left ventricular ejection fraction or plasma levels of N-terminal pro-B-type natriuretic peptide (NT-proBNP) after 6 months of treatment. In contrast, the atorvastatin group showed a significant increase in the delayed heart/mediastinum count ratio (2.18{+-}0.4 vs. 2.36{+-}0.4, P<0.0001), and the washout rate was significantly decreased (34.8{+-}5.7 vs. 32.6{+-}6.3%, P=0.0001) after 6 months of treatment compared with the baseline values. The plasma NT-proBNP level was also significantly decreased (729{+-}858 vs. 558{+-}747 pg/ml, P=0.0139). Lipophilic atorvastatin but not hydrophilic rosuvastatin improves cardiac sympathetic nerve activity in CHF patients with DCM. (author)

  6. Combined thallium-201 and dynamic iodine-123 iodophenylpentadecanoic acid single-photon emission computed tomography in patients after acute myocardial infarction with effective reperfusion.

    Science.gov (United States)

    Richter, W S; Beckmann, S; Cordes, M; Schuppenhauer, T; Schartl, M; Munz, D L

    2000-12-01

    Considerable derangements of energy metabolism are to be expected during ischemia and reperfusion. In ischemic myocardium, the oxidative degradation of carbohydrates is shifted toward the anaerobic production of lactate and the oxidation of fatty acids is suppressed. The aim of this study was to examine the uptake and metabolism of iodine-123 (123I) iodophenylpentadecanoic acid (IPPA) in stunned myocardium. In 15 patients, SPECT with 201Tl and 123I IPPA as well as echocardiography with low-dose dobutamine stimulation were performed 12 +/- 5 days after myocardial infarction with reperfusion. Follow-up echocardiography was carried out 24 +/- 8 days later for documentation of functional improvement. Uptake of 201Tl and 123I IPPA were obtained in five left ventricular segments, and dynamic SPECT imaging was used for calculation of the fast and the slow components of the biexponential myocardial 123I IPPA clearance. Wall motion improved in 14 of 26 dysfunctional segments (54%). Stunned segments were characterized by a reduced 123I IPPA extraction, a shorter half-life of the fast, and a longer half-life of the slow clearance component. All parameters of the combined 201Tl/123I IPPA study predicted functional recovery with similar accuracies (area under the receiver operator characteristic curves between 0.68 and 0.76; p = NS). Analysis of 201Tl uptake alone could not predict functional recovery in this study. Stunned myocardium is characterized by a disturbance of fatty acid metabolism. For prediction of functional improvement, 123I IPPA imaging added significant diagnostic information.

  7. Role of {sup 18F} FDG PET/CT, {sup 123I} MIBG SPECT, and CT in Restaging patients Affected by Malignant Pheochromocytoma

    Energy Technology Data Exchange (ETDEWEB)

    Cantalamessa, Antonio; Caobelli, Antonio; Vavassori, Francesca [Habilita Istituto Clinico, Bergamo (Italy); Caobelli, Federico [Univ. of Brescia, Brescia (Italy); Paghera, Barbara [Spedali Civili, Brescia (Italy)

    2011-06-15

    Pheochromocytoma (PH) is a rare catecholamine secreting tumor that arises from chromaffin tissue within the adrenal medulla and extra adrenal sites; commonly it is sporadic, and malignant PH accounts for about 10% of all cases. Several imaging modalities have been used for the diagnosis and staging og this tumor: functional imaging using radio labelled metaiodobenzylguanidine and, more recently, {sup 18F} fluorodeoxyglucose positron emission tomography ({sup 18F} FDG PET/CT), which offers substantial sensitivity and specificity to correctly detect metastatic PH and helps to identify patients suitable for treatment with radiopharmaceuticals. The aim of our study was to compare CT, {sup 18F} FDG PET/CT, and {sup 123I} metaiodobenzylguanidine single photon emission tomography ({sup 123I} MIBG SPECT) as feasible methods to restage patients diagnosed histologically with PH. We retrospectively evaluated 38 patients (27 females and 11 males; mean age: 44{+-}15 years) with malignant PH documented histologically after surgical intervention. These patients underwent CT, {sup 18F} FDG PET/CT, and {sup 123I} MIBG SPECT. {sup 18F} FDG PET/CT showed positive results for neoplastic tissue in 33/38 patients (86.8%) and negative in 5/38 (13.2%), in concordance with CT alone. {sup 123I} MIBG SPECT was positive in 30/38 patients (78.9%) and negative in 8/38 (21.1%). No differences in lesion numbers were found between {sup 18F} FDG PET/CT and {sup 123I} MIBG SPECT. {sup 18F} FDG PET/CT could more accurately restage patients with PH than CT and {sup 123I} MIBG SPECT, also in the absence of a staging study.

  8. Clinical value of iodine-123 beta-methyliodophenyl pentadecanoic acid (BMIPP) myocardial single photon emission computed tomography for predicting cardiac death among patients with chronic heart failure

    International Nuclear Information System (INIS)

    Sasaki, Ryu; Usui, Takashi; Mitani, Isao

    2003-01-01

    In the present study, the effectiveness of 123 I-β-methyliodophenyl pentadecanoic acid (BMIPP) single photon emission computed tomography (SPECT) for predicting cardiac death of patients with chronic heart failure was evaluated. Abnormalities of fatty acid metabolism are found in patients with chronic heart failure and BMIPP was developed as a tracer for scintigraphic assessment of myocardial fatty acid utilization. The study group comprised 74 patients with chronic heart failure with a left ventricular ejection fraction (LVEF) 201 Tl SPECT and BMIPP SPECT. The uptake of tracer was scored semiquantitatively from 0 (normal) to 4 (defect) in 20 segments and a total defect score (TDS) for all 20 segments was calculated. On planar images the mediastinum to heart count ratio (H/M) was calculated for the BMIPP and Tl studies, and the H/M BMIPP :H/M Tl (H/M BMIPP divided by H/M Tl ) was also calculated. The mean follow-up period was 660 days and there were 17 cases of cardiac death. Multivariate analysis identified H/M BMIPP :H/M Tl (p BMIPP :H/M Tl was situated to the left relative to LVEF. Analysis of the myocardial metabolism by BMIPP SPECT can predict the high-risk patients with chronic heart failure. (author)

  9. Apparatus of hot cell for iodine-123 production

    International Nuclear Information System (INIS)

    Almeida, G.L. de; Rautenberg, F.A.; Souza, A.S.F. de.

    1986-01-01

    The hot cell installation at IEN cyclotron (Brazilian-CNEN) for sup(123)I production is presented. Several devices, such as, tube furnace coupling system, tube furnace driving system, sup(123)I target transfer system, product extraction system, furnace control system, and effluent systems, were constructed and modified for implanting process engineering. The requirements of safety engineering for operation process were based on ALARA concept. (M.C.K.)

  10. Metabolic cardiac imaging in severe coronary disease: assessment of viability with iodine-123-iodophenylpentadecanoic acid and multicrystal gamma camera, and correlation with biopsy.

    Science.gov (United States)

    Murray, G; Schad, N; Ladd, W; Allie, D; vander Zwagg, R; Avet, P; Rockett, J

    1992-07-01

    Fifteen patients with coronary disease and resting left ventricular ejection fractions of less than or equal to 0.35 underwent resting metabolic cardiac imaging utilizing 1 mCi [123I]iodophenylpentadecanoic acid (IPPA) intravenously and a multicrystal gamma camera. Parametric images of regional rates of IPPA clearance and accumulation were generated. Forty-two vascular territories (22 infarcted) were evaluated by metabolic imaging as well as transmural myocardial biopsy. Despite resting akinesis or dyskinesis in 20/22 (91%) infarcted territories, 16/22 (73%) of these territories were metabolically viable. Transmural myocardial biopsies in all patients (43 sites, 42 vascular territories) during coronary bypass surgery confirmed IPPA results in 39/43 patients (91%). When compared to biopsy, scan sensitivity for viability was 33/36 (92%) with a specificity of 6/7 (86%). Eighty percent of bypassed, infarcted but IPPA viable segments demonstrated improved regional systolic wall motion postoperatively as assessed by exercise radionuclide angiography. We conclude resting IPPA imaging identifies viable myocardium, thereby providing a safe, cost-effective technique for myocardial viability assessment.

  11. Radioiodinated Rhodamine-123: a potential cationic hepatobiliary imaging agent

    International Nuclear Information System (INIS)

    Moonen, P.; Gorree, G.C.M.; Hoekstra, A.

    1987-01-01

    The labelling of the cationic dye Rhodamine-123 with 125 I is described. The biodistribution of the iodinated Rhodamine-123 has been determined at different time intervals after intravenous injection into fasted rats. It turned out that the dye is predominantly cleared by the liver and discharged into the bile. The bile acid taurocholate did not enhance the rate of excretion of 125 I-Rhodamine-123. (author)

  12. Comparison of 18F-fluoro-L-DOPA, 18F-fluoro-deoxyglucose, and 18F-fluorodopamine PET and 123I-MIBG scintigraphy in the localization of pheochromocytoma and paraganglioma.

    NARCIS (Netherlands)

    Timmers, H.J.L.M.; Chen, C.C.; Carrasquillo, J.A.; Whatley, M.; Ling, A.; Havekes, B.; Eisenhofer, G.; Martiniova, L.; Adams, K.T.; Pacak, K.

    2009-01-01

    CONTEXT: Besides (123)I-metaiodobenzylguanidine (MIBG), positron emission tomography (PET) agents are available for the localization of paraganglioma (PGL), including (18)F-3,4-dihydroxyphenylalanine (DOPA), (18)F-fluoro-2-deoxy-D-glucose ((18)F-FDG), and (18)F-fluorodopamine ((18)F-FDA). OBJECTIVE:

  13. Labeling and quality control of 123I-MIBG

    International Nuclear Information System (INIS)

    Figols de Barboza, Marycel Rosa

    2002-01-01

    This report describes a method to facilitate routine production of 123 I-MIBG in Radiopharmacy Centre of IPEN-CNEN/SP. Iodine-123 radioisotope is produced in the form of sodium iodide in Cyclone-30 (IBA) at IPEN-CNEN/SP through proton irradiation of gaseous 124 Xe target. The labelling procedure uses MIBG-sulphate and leads to 123 I-MIBG with radiochemical purity at least 98% and specific activity of 300-380 MBq/mg

  14. Imaging active lymphocytic infiltration in coeliac disease with iodine-123-interleukin-2 and the response to diet

    Energy Technology Data Exchange (ETDEWEB)

    Signore, A.; Chianelli, M.; Annovazzi, A.; Rossi, M.; Greco, M.; Ronga, G.; Picarelli, A. [Nuclear Medicine Unit (Nu.M.E.D. Group) and Gastroenterology Unit, Department of Clinical Sciences, University of Rome ' ' La Sapienza' ' (Italy); Maiuri, L. [Inst. of Paediatrics, Children' s Hospital Posilipon, University ' ' Federico II' ' , Naples (Italy); Britton, K.E. [Dept. of Nuclear Medicine, St. Bartholomew' s Hospital, London (United Kingdom)

    2000-01-01

    Coeliac disease is diagnosed by the presence of specific antibodies and a jejunal biopsy showing mucosal atrophy and mononuclear cell infiltration. Mucosal cell-mediated immune response is considered the central event in the pathogenesis of coeliac disease, and untreated coeliac patients show specific features of T-cell activation in the small intestine. Here we describe the use of iodine-123-interleukin-2 scintigraphy in coeliac patients as a non-invasive tool for detection of lymphocytic infiltration in the small bowel and its use for therapy follow-up, and we demonstrate the specificity of binding of labelled-IL2 to activated lymphocytes by ex-vivo autoradiography of jejunal biopsies. {sup 123}I-IL2 was administered i.v. [74 MBq (2 mCi)], and gamma camera images were acquired after 1 h. Ten patients were studied with {sup 123}I-IL2 scintigraphy at diagnosis and seven were also investigated after 12-19 months of gluten-free diet. Results were expressed as target-to-background radioactivity ratios in six different bowel regions before and after the diet. At the time of diagnosis all patients showed a significantly higher bowel uptake of {sup 123}I-IL2 than normal subjects (P<0.003 in all regions). A significant correlation was found between jejunal radioactivity and the number of IL2R+ve lymphocytes per millimetre of jejunal mucosa as detected by immunostaining of jejunal biopsy (r{sup 2}=0.66; P=0.008). Autoradiography of jejunal biopsies confirmed that labelled-IL2 only binds to activated T-lymphocytes infiltrating the gut mucosa. After 1 year of the diet, bowel uptake of {sup 123}I-IL2 significantly decreased in five out of six regions (P<0.03), although two patients still had a positive IL2 scintigraphy in one region. We conclude that {sup 123}I-IL2 scintigraphy is a sensitive non-invasive technique for assessing in vivo the presence of activated mononuclear cells in the bowel of patients affected by coeliac disease. Unlike jejunal biopsy, this method provides

  15. Iodine-123 lodobenzamide imaging, MRI and apomorphine testing in the evaluation of patients with Parkinsonism.

    Energy Technology Data Exchange (ETDEWEB)

    Van der Schaaf, A.A.; Stell, R.; Groom, G.N.; Lambrecht, R.; Najdovski, L.; Collier, T.L.; Cardaci, G.; Davis, S.; Laing, B.; Mastaglia, F.L.; O`Brien, J. [Sir Charles Gairdner Hospital, Perth, WA, (Australia)]|[ANSTO, Lucas Heights, NSW, (Australia). The Biomedicine and Health Program

    1997-09-01

    Full text; The clinical distinction between idiopathic Parkinson`s disease (IPD) and other neurodegenerative disorders which mimic this condition is important in patient management. Iodine-123 lodobenzamide (IBZM) SPECT imaging of cerebral dopamine-2 (D{sub 2}) receptors has been proposed as a means of distinguishing between IPD and atypical variants, including such Parkinsonian syndromes (PS) as multi-system atrophy and progressive supranuclear palsy, and to predict long-term responsiveness to dopaminergic drugs. Apomorphine testing is currently in use for the latter purpose. To assess the role of IBZM SPECT, MRI and apomorphine testing in categorising patients with Parkinsonian symptoms and for predicting therapeutic response, we studied 40 subjects, 18 of whom had IPD. SPECT brain studies were carried out two hours after the intravenous injection of approximately 185 MBq of {sup 123}I IBZM. Semiquantitative IBZM striatal/occipital cortex uptake ratios in the IPD group were 1.53 + 0.17 (mean + S.D.), and in the non-lPD group 1.53 {+-} 0.29. Of the 11 IPD patients and 19 non-lPD patients who had MRI, none and two, respectively, showed iron deposition in the basal ganglia. Eleven of 13 IPD and 3 of 18 non-lPD subjects had a positive apomorphine test, while 15 of 15 IPD and 5 of 19 non-lPD subjects responded to dopaminergic therapy. When patients were classified into responders (R) (n 20) and non-responders (NR) (n = 14), the IBZM ratios were 1.56 {+-} 0.22 and 1.47 {+-} 0.29 respectively (no significant difference between the groups). The apomorphine test accurately predicted response, being positive in 13 of 15 R and negative in 11 of 12 NR. We conclude that {sup 123}I SPECT is not helpful in differentiating IPD from PS, nor in predicting response to dopaminergic drugs.

  16. Iodine-123 lodobenzamide imaging, MRI and apomorphine testing in the evaluation of patients with Parkinsonism

    International Nuclear Information System (INIS)

    Van der Schaaf, A.A.; Stell, R.; Groom, G.N.; Lambrecht, R.; Najdovski, L.; Collier, T.L.; Cardaci, G.; Davis, S.; Laing, B.; Mastaglia, F.L.; O'Brien, J.; ANSTO, Lucas Heights, NSW,

    1997-01-01

    Full text; The clinical distinction between idiopathic Parkinson's disease (IPD) and other neurodegenerative disorders which mimic this condition is important in patient management. Iodine-123 lodobenzamide (IBZM) SPECT imaging of cerebral dopamine-2 (D 2 ) receptors has been proposed as a means of distinguishing between IPD and atypical variants, including such Parkinsonian syndromes (PS) as multi-system atrophy and progressive supranuclear palsy, and to predict long-term responsiveness to dopaminergic drugs. Apomorphine testing is currently in use for the latter purpose. To assess the role of IBZM SPECT, MRI and apomorphine testing in categorising patients with Parkinsonian symptoms and for predicting therapeutic response, we studied 40 subjects, 18 of whom had IPD. SPECT brain studies were carried out two hours after the intravenous injection of approximately 185 MBq of 123 I IBZM. Semiquantitative IBZM striatal/occipital cortex uptake ratios in the IPD group were 1.53 + 0.17 (mean + S.D.), and in the non-lPD group 1.53 ± 0.29. Of the 11 IPD patients and 19 non-lPD patients who had MRI, none and two, respectively, showed iron deposition in the basal ganglia. Eleven of 13 IPD and 3 of 18 non-lPD subjects had a positive apomorphine test, while 15 of 15 IPD and 5 of 19 non-lPD subjects responded to dopaminergic therapy. When patients were classified into responders (R) (n 20) and non-responders (NR) (n = 14), the IBZM ratios were 1.56 ± 0.22 and 1.47 ± 0.29 respectively (no significant difference between the groups). The apomorphine test accurately predicted response, being positive in 13 of 15 R and negative in 11 of 12 NR. We conclude that 123 I SPECT is not helpful in differentiating IPD from PS, nor in predicting response to dopaminergic drugs

  17. Prediction of cardiac sympathetic nerve activity and cardiac functional outcome after treatment in patients with dilated cardiomyopathy. Examination using dobutamine gated blood pool scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Kasama, Shu; Toyama, Takuji; Iwasaki, Tsutomu; Suzuki, Tadashi [Gunma Univ., Maebashi (Japan). School of Medicine; Hoshizaki, Hiroshi; Oshima, Shigeru; Taniguchi, Koichi; Nagai, Ryozo

    2000-07-01

    This study evaluated whether dobutamine gated blood pool scintigraphy can predict improvement of cardiac sympathetic nerve activity and cardiac function. Sixteen patients (10 men and 6 women, mean age 59{+-}13 years) with dilated cardiomyopathy underwent dobutamine gated blood pool scintigraphy to measure left ventricular ejection fraction (LVEF) using tracer at 0, 5, 10 and 15 {mu}g/kg/min before treatment. Patients were divided into good responders (LVEF increase {>=}15%) 8 patients (GR Group) and poor responders (LVEF increase <15%) 8 patients (PR Group) after treatment with {beta}-blocker or amiodarone with a background treatment of digitalis, diuretics and angiotensin converting enzyme inhibitor. I-123 metaiodobenzylguanidine (MIBG) imaging to evaluate cardiac sympathetic nerve activity and echocardiography were performed before and at one year after treatment. MIBG imaging was obtained 4 hours after tracer injection, and the heart/mediastinum count ratio (H/M ratio) calculated from the anterior planar image and the total defect score (TDS) from the single photon emission computed tomography image. LVEF and left ventricular endo-diastolic dimension (LVDd) were measured by echocardiography and New York Heart Association (NYHA) functional class was evaluated. The GR Group showed TDS decreased from 28{+-}6 to 17{+-}12 (p<0.05), H/M ratio increased from 1.79{+-}0.26 to 2.07{+-}0.32 (p<0.05), LVEF increased from 29{+-}8% to 48{+-}10% (p<0.01), and LVDd decreased from 65{+-}4 mm to 58{+-}5 mm (p<0.05). In contrast, the PR group showed no significant changes in TDS. H/M ratio, LVEF and LVDd. NYHA functional class improved in both groups. The improvement was better in the GR Group than in the PR group. Dobutamine gated blood pool scintigraphy is useful to predict the improvement of the cardiac sympathetic nerve activity and cardiac function, and symptoms after treatment in patients with dilated cardiomyopathy. (author)

  18. Myocardial iodine concentration measurement using dual-energy computed tomography for the diagnosis of cardiac amyloidosis. A pilot study

    International Nuclear Information System (INIS)

    Chevance, Virgile; Legou, Francois; Ridouani, Fourat; Damy, Thibaud; Tacher, Vania; Kobeiter, Hicham; Luciani, Alain; Rahmouni, Alain; Deux, Jean-Francois

    2018-01-01

    To measure myocardium iodine concentration (MIC) in patients with cardiac amyloidosis (CA) using dual-energy computed tomography (DECT). Twenty-two patients with CA, 13 with non-amyloid hypertrophic cardiomyopathies (CH) and 10 control patients were explored with pre-contrast, arterial and 5-minute DECT acquisition (Iomeprol; 1.5 mL/kg). Inter-ventricular septum (IVS) thickness, blood pool iodine concentration (BPIC), MIC (mg/mL), iodine ratio and extra-cellular volume (ECV) were calculated. IVS thickness was significantly (p < 0.001) higher in CA (17 ± 4 mm) and CH (15 ± 3 mm) patients than in control patients (10 ± 1 mm). CA patients exhibited significantly (p < 0.001) higher 5-minute MIC [2.6 (2.3-3.1) mg/mL], 5-minute iodine ratio (0.88 ± 0.12) and ECV (0.56 ± 0.07) than CH [1.7 (1.4-2.2) mg/mL, 0.57 ± 0.07 and 0.36 ± 0.05, respectively] and control patients [1.9 (1.7-2.4) mg/mL, 0.58 ± 0.07 and 0.35 ± 0.04, respectively]. CH and control patients exhibited similar values (p = 0.9). The area under the curve of 5-minute iodine ratio for the differential diagnosis of CA from CH patients was 0.99 (0.73-1.0; p = 0.001). With a threshold of 0.65, the sensitivity and specificity of 5-minute iodine ratio were 100% and 92%, respectively. Five-minute MIC and iodine ratio were increased in CA patients and exhibited best diagnosis performance to diagnose CA in comparison to other parameters. (orig.)

  19. Myocardial iodine concentration measurement using dual-energy computed tomography for the diagnosis of cardiac amyloidosis. A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Chevance, Virgile; Legou, Francois; Ridouani, Fourat [AP-HP (Assistance Publique-Hopitaux de Paris, Creteil), Groupe Hospitalier Henri Mondor-Albert Chenevier, Service d' Imagerie Medicale, Creteil (France); Damy, Thibaud [AP-HP (Assistance Publique-Hopitaux de Paris, Creteil), Hospitalier Henri Mondor-Albert Chenevier, Service de Cardiologie, Creteil (France); Universite Paris-Est-Creteil (UPEC), DHU (Departement Hospitalo-Universitaire), ATVB Ageing-Thorax-Vessels-Blood, IMRB Institut Mondor de Recherche Biomedicale, Creteil (France); Universite Paris-Est-Creteil (UPEC), GRC Amyloid Research Institute and Reseau Amylose Mondor, Groupe Hospitalier Henri Mondor-Albert Chenevier, Creteil (France); Tacher, Vania; Kobeiter, Hicham [AP-HP (Assistance Publique-Hopitaux de Paris, Creteil), Groupe Hospitalier Henri Mondor-Albert Chenevier, Service d' Imagerie Medicale, Creteil (France); Universite Paris-Est-Creteil (UPEC), DHU (Departement Hospitalo-Universitaire), ATVB Ageing-Thorax-Vessels-Blood, IMRB Institut Mondor de Recherche Biomedicale, Creteil (France); Luciani, Alain; Rahmouni, Alain [AP-HP (Assistance Publique-Hopitaux de Paris, Creteil), Groupe Hospitalier Henri Mondor-Albert Chenevier, Service d' Imagerie Medicale, Creteil (France); Universite Paris-Est-Creteil, (UPEC), DHU (Departement Hospitalo-Universitaire) VIC Virus-Immunity-Cancer, IMRB Institut Mondor de Recherche Biomedicale, Creteil (France); Deux, Jean-Francois [AP-HP (Assistance Publique-Hopitaux de Paris, Creteil), Groupe Hospitalier Henri Mondor-Albert Chenevier, Service d' Imagerie Medicale, Creteil (France); Universite Paris-Est-Creteil, (UPEC), DHU (Departement Hospitalo-Universitaire) ATVB Ageing-Thorax-Vessels-Blood, IMRB Institut Mondor de Recherche Biomedicale, Creteil (France); Universite Paris-Est-Creteil (UPEC), GRC Amyloid Research Institute and Reseau Amylose Mondor, Groupe Hospitalier Henri Mondor-Albert Chenevier, Creteil (France)

    2018-02-15

    To measure myocardium iodine concentration (MIC) in patients with cardiac amyloidosis (CA) using dual-energy computed tomography (DECT). Twenty-two patients with CA, 13 with non-amyloid hypertrophic cardiomyopathies (CH) and 10 control patients were explored with pre-contrast, arterial and 5-minute DECT acquisition (Iomeprol; 1.5 mL/kg). Inter-ventricular septum (IVS) thickness, blood pool iodine concentration (BPIC), MIC (mg/mL), iodine ratio and extra-cellular volume (ECV) were calculated. IVS thickness was significantly (p < 0.001) higher in CA (17 ± 4 mm) and CH (15 ± 3 mm) patients than in control patients (10 ± 1 mm). CA patients exhibited significantly (p < 0.001) higher 5-minute MIC [2.6 (2.3-3.1) mg/mL], 5-minute iodine ratio (0.88 ± 0.12) and ECV (0.56 ± 0.07) than CH [1.7 (1.4-2.2) mg/mL, 0.57 ± 0.07 and 0.36 ± 0.05, respectively] and control patients [1.9 (1.7-2.4) mg/mL, 0.58 ± 0.07 and 0.35 ± 0.04, respectively]. CH and control patients exhibited similar values (p = 0.9). The area under the curve of 5-minute iodine ratio for the differential diagnosis of CA from CH patients was 0.99 (0.73-1.0; p = 0.001). With a threshold of 0.65, the sensitivity and specificity of 5-minute iodine ratio were 100% and 92%, respectively. Five-minute MIC and iodine ratio were increased in CA patients and exhibited best diagnosis performance to diagnose CA in comparison to other parameters. (orig.)

  20. PET and SPET tracers for mapping the cardiac nervous system

    International Nuclear Information System (INIS)

    Langer, Oliver; Halldin, Christer

    2002-01-01

    The human cardiac nervous system consists of a sympathetic and a parasympathetic branch with (-)-norepinephrine and acetylcholine as the respective endogenous neurotransmitters. Dysfunction of the cardiac nervous system is implicated in various types of cardiac disease, such as heart failure, myocardial infarction and diabetic autonomic neuropathy. In vivo assessment of the distribution and function of cardiac sympathetic and parasympathetic neurones with positron emission tomography (PET) and single-photon emission tomography (SPET) can be achieved by means of a number of carbon-11-, fluorine-18-, bromine-76- and iodine-123-labelled tracer molecules. Available tracers for mapping sympathetic neurones can be divided into radiolabelled catecholamines, such as 6-[ 18 F]fluorodopamine, (-)-6-[ 18 F]fluoronorepinephrine and (-)-[ 11 C]epinephrine, and radiolabelled catecholamine analogues, such as [ 123 I]meta-iodobenzylguanidine, [ 11 C]meta-hydroxyephedrine, [ 18 F]fluorometaraminol, [ 11 C]phenylephrine and meta-[ 76 Br]bromobenzylguanidine. Resistance to metabolism by monoamine oxidase and catechol-O-methyl transferase simplifies the myocardial kinetics of the second group. Both groups of compounds are excellent agents for an overall assessment of sympathetic innervation. Biomathematical modelling of tracer kinetics is complicated by the complexity of the steps governing neuronal uptake, retention and release of these agents as well as by their high neuronal affinity, which leads to partial flow dependence of uptake. Mapping of cardiac parasympathetic neurones is limited by a low density and focal distribution pattern of these neurones in myocardium. Available tracers are derivatives of vesamicol, a molecule that binds to a receptor associated with the vesicular acetylcholine transporter. Compounds like (-)-[ 18 F]fluoroethoxybenzovesamicol display a high degree of non-specific binding in myocardium which restricts their utility for cardiac neuronal imaging. (orig.)

  1. Clinical usefulness of 123I-MIBG myocardial spect in patients with cardiac sarcoidosis

    International Nuclear Information System (INIS)

    Kobayashi, Keiko; Hatsumi, Chie; Fujioka, Haruto

    1996-01-01

    This study was undertaken to assess whether 123 I-MIBG scintigraphy is useful to detect cardiac involvements of sarcoidosis. In 45 patients with sarcoidosis, dual SPECT with 123 I-MIBG and 201 Tl-Cl(Tl) were performed, and the findings were compared with electrocardiogram (ECG), 24 hour Holter ECG and ultrasound echocardiography. In order to evaluate cardiac involvements, Tl and MIBG extent score (E.S.) and severity score (S.S.) were calculated by a Bull's eye map in addition to visual evaluation. Abnormal findings were recognized in 8.9% of all subjects in echocardiography, in 22.2% of those in ECG and Holter ECG, in 40% of those in Tl scintigraphy, and in 64.4% of those in MIBG scintigraphy. All of the Tl and MIBG abnormalities were detected in left ventricles, especially at the basal septal wall. At the inferior wall, abnormalities were observed more frequently by MIBG than by Tl. Tl E.S., Tl S.S. and MIBG E.S. were significantly higher in 10 patients with abnormal ECG findings than in 35 patients with normal ECG findings. Also, all of 10 patients with abnormal ECG findings had abnormal MIBG image, but 3 of them showed normal Tl images. 11 of 35 patients with normal ECG findings showed abnormal Tl and MIBG images (group A), 8 of 35 patients showed normal Tl images and abnormal MIBG images (group B), and 16 of 35 patients showed normal Tl and MIBG images (group C). MIBG S.S. of group A (11.3±7.8) was significantly higher than that of group B (5.3±3.1) or group C (2.6±3.2). Furthermore, in group A, MIBG S.S. was significantly higher than Tl S.S. (5.5±2.8). In a case of normal ECG with abnormal MIBG images, we seriously suspect cardiac involvements and recommend repeated Holter ECG tests as necessary in order to detect critical arrythmia. MIBG scintigraphy appeared to be a sensitive and useful method for the early detection of cardiac sarcoidosis. (J.P.N.)

  2. Multivariate cluster analysis of dynamic iodine-123 iodobenzamide SPET dopamine D2receptor images in schizophrenia

    International Nuclear Information System (INIS)

    Acton, P.D.; Pilowsky, L.S.; Costa, D.C.; Ell, P.J.

    1997-01-01

    This paper describes the application of a multivariate statistical technique to investigate striatal dopamine D 2 receptor concentrations measured by iodine-123 iodobenzamide ( 123 I-IBZM) single-photon emission tomography (SPET). This technique enables the automatic segmentation of dynamic nuclear medicine images based on the underlying time-activity curves present in the data. Once the time-activity curves have been extracted, each pixel can be mapped back on to the underlying distribution, considerably reducing image noise. Cluster analysis has been verified using computer simulations and phantom studies. The technique has been applied to SPET images of dopamine D 2 receptors in a total of 20 healthy and 20 schizophrenic volunteers (22 male, 18 female), using the ligand 123 I-IBZM. Following automatic image segmentation, the concentration of striatal dopamine D 2 receptors shows a significant left-sided asymmetry in male schizophrenics compared with male controls. The mean left-minus-right laterality index for controls is -1.52 (95% CI -3.72-0.66) and for patients 4.04 (95% CI 1.07-7.01). Analysis of variance shows a case-by-sex-by-side interaction, with F=10.01, P=0.005. We can now demonstrate that the previously observed male sex-specific D 2 receptor asymmetry in schizophrenia, which had failed to attain statistical significance, is valid. Cluster analysis of dynamic nuclear medicine studies provides a powerful tool for automatic segmentation and noise reduction of the images, removing much of the subjectivity inherent in region-of-interest analysis. The observed striatal D 2 asymmetry could reflect long hypothesized disruptions in dopamine-rich cortico-striatal-limbic circuits in schizophrenic males. (orig.). With 4 figs., 2 tabs

  3. Optimizing Parkinson's disease diagnosis: the role of a dual nuclear imaging algorithm.

    Science.gov (United States)

    Langston, J William; Wiley, Jesse C; Tagliati, Michele

    2018-01-01

    The diagnosis of Parkinson's disease (PD) currently relies almost exclusively on the clinical judgment of an experienced neurologist, ideally a specialist in movement disorders. However, such clinical diagnosis is often incorrect in a large percentage of patients, particularly in the early stages of the disease. A commercially available, objective and quantitative marker of nigrostriatal neurodegeneration was recently provided by 123-iodine 123 I-ioflupane SPECT imaging, which is however unable to differentiate PD from a variety of other parkinsonian syndromes associated with striatal dopamine deficiency. There is evidence to support an algorithm utilizing a dual neuroimaging strategy combining 123 I-ioflupane SPECT and the noradrenergic receptor ligand 123 I-metaiodobenzylguanidine (MIBG), which assesses the post-ganglion peripheral autonomic nervous system. Evolving concepts regarding the synucleinopathy affecting the central and peripheral autonomic nervous systems as part of a multisystem disease are reviewed to sustain such strategy. Data are presented to show how MIBG deficits are a common feature of multisystem Lewy body disease and can be used as a unique feature to distinguish PD from atypical parkinsonisms. We propose that the combination of cardiac (MIBG) and cerebral 123 I-ioflupane SPECT could satisfy one of the most significant unmet needs of current PD diagnosis and management, namely the early and accurate diagnosis of patients with typical Lewy body PD. Exemplary case scenarios will be described, highlighting how dual neuroimaging strategy can maximize diagnostic accuracy for patient care, clinical trials, pre-symptomatic PD screening, and special cases provided by specific genetic mutations associated with PD.

  4. Fatty acids labelled in the. omega. -position with iodine isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Mathieu, J.P.; Busquet, G.; Comet, M. (Universite Scientifique et Medicale de Grenoble, 38 - La Tronche (France)); Riche, F.; Vidal, M. (Laboratoire d' Etudes Dynamiques et Structurales de la Selectivite, 38 - Grenoble (France)); Coornaert, S.; Bardy, A. (CEA, Centre de Saclay, 91 - Gif-sur-Yvette (France)); Godart, J. (Institut des Sciences Nucleaires, 38 - Grenoble (France))

    1982-01-01

    The synthesis of saturated acetylenic and olefinic (Z or E) ..omega..-iodinated fatty acids has been carried out and their labelling with iodine-131 or 123 by exchange I/sup -/, *I/sup -/ has been studied. The influence of several parameters -water and fatty acid concentrations, specific activity, labelling solution acidity, iodine carrier presence- on this exchange reaction has been noted, enabling experimental conditions to be defined that produce labelling yields of greater than 95%. These results should lead to widespread clinical use of iodine labelled fatty acids.

  5. Evaluation of diffuse thyroid diseases by computed tomography and 123I thyroidal uptake

    International Nuclear Information System (INIS)

    Kurihara, Yoshiko; Imanishi, Yoshimasa; Ehara, Norishige

    1991-01-01

    Understanding the iodine kinetics in the thyroid is useful for the diagnosis of a patient with diffuse thyroid disease. In this study, 9 controls and 50 patients with diffuse thyroid diseases, we evaluated diffuse thyroid diseases with 123 I thyroidal uptake and volume, iodine concentration, and net iodine content measured by computed tomography. There was no significant correlation between volume, iodine concentration, and net iodine content of the thyroid and 123 I thyroidal uptake. The thyroid volume in Graves' and Hashimoto's diseases was significantly larger than that in the control group. The thyroid iodine concentration in Graves' and Hashimoto's diseases was significantly smaller than that in the control group. The thyroid net iodine content in Hashimoto's disease was significantly smaller than that in the control group. Although most of the patients with Graves' disease had more increased radioiodine thyroidal uptake than the control group, there was no significant difference between them in the mean of the thyroid net iodine content. But the variance of net iodine contents in the former was significantly larger than that in the latter. The thyroid net iodine content was very low in all patients with very high thyroglobulin hemaggrugated antibody (TGHA) value although it was nearly normal in some patients with normal TGHA value. It was suggested that iodine concentration and net iodine content might be determined not only by iodine uptake but also by release and/or leakage of iodine compounds from the thyroid, which might depend on some antithyroid antibodies. (author)

  6. Recent developments in the field of 123I-radiopharmaceuticals

    International Nuclear Information System (INIS)

    Machulla, H.J.; Knust, E.J.

    1984-01-01

    Due to its advantageous nuclear physical properties iodine-123 is an excellent label for radiopharmaceuticals very well suited for measurements by γ-cameras and single-photon emission tomography. The development of 123 I-radiopharmaceuticals should be based on a clear biochemical concept, reliable labelling procedures and careful pharmacokinetic studies in order to evaluate the physiological behaviour of the radioiodinated compounds being analogues of metabolic substrates. The development of 123 I-labelled fatty acids and biogenic amines clearly proved the successful use of 123 I for labelling compounds applied in medical diagnosis. (orig.) [de

  7. Beneficial effect of perindopril on cardiac sympathetic nerve activity and brain natriuretic peptide in patients with chronic heart failure. Comparison with enalapril

    International Nuclear Information System (INIS)

    Tsutamoto, Takayoshi; Tanaka, Toshinari; Sakai, Hiroshi

    2008-01-01

    In patients with chronic heart failure (CHF), it remains unclear whether perindopril is more cardioprotective than enalapril. Forty-five stable CHF outpatients undergoing conventional therapy including enalapril therapy were randomized to 2 groups [group I (n=24): continuous enalapril treatment; group II (n=21): enalapril was changed to perindopril]. Cardiac sympathetic nerve activity was evaluated using cardiac 123 I-metaiodobenzylguanidine (MIBG) scintigraphy, hemodynamic parameters and neurohumoral factors before and 6 months after treatment. There was no difference in baseline characteristics between the 2 groups. In group I, there were no changes in MIBG parameters, left ventricular ejection fraction (LVEF) or plasma level of brain natriuretic peptide (BNP). In contrast, in group II delayed heart/mediastinum count ratio was significantly increased (2.0±0.07 vs 2.15±0.07, p=0.013) and the washout rate was significantly decreased (33.0±1.4 vs 30.5±1.2, p=0.030) after 6 months compared with the baseline value. In addition, LVEF was significantly increased and the plasma BNP level was significantly decreased. These findings suggest that for the treatment of CHF, perindopril is superior to enalapril with respect of cardiac sympathetic nerve activity and BNP. (author)

  8. Relationship between iodine-123-beta-methyl-p-iodophenyl-pentadecanoic acid washout ratio and oxygen consumption in normal and ischemic myocardium

    International Nuclear Information System (INIS)

    Saito, Kimimasa; Okamoto, Ryuji; Saito, Yasuhiro

    1997-01-01

    The relationship between oxygen consumption and iodine-123-beta-methyl-p-iodophenyl-pentadecanoic acid ( 123 I-BMIPP) washout at rest and after exercise was investigated in normal and ischemic myocardium. Sixteen healthy volunteers and 14 patients with ischemic heart disease were examined. After injection of 111 MBq of 123 I-BMIPP, serial single photon emission computed tomography imaging was performed to evaluate washout ratio after 30 min and 1 hour of rest and after exercise. In the volunteers, the mean washout ratio was 3.3±3.5% after 1 hour of rest and increased during exercise. The exercise washout ratio showed a better correlation with net pressure rate product (net PRP: cumulative values of PRP during exercise) than with the peak PRP. The exercise washout ratio showed a strong correlation with the net PRP in the range from 180 to 300x10 3 mmHg·beat/min and a plateau of 10-15%. In the nine ischemic patients with net PRP≥300x10 3 mmHg·beat/min, the exercise washout ratio values were significantly elevated in normal segments relative to ischemic segments (10.1±1.9% vs 4.7±2.9%, p 3 mmHg·beat/min, washout ratio at rest and after exercise did not differ significantly between normal and ischemic segments. 123 I-BMIPP washout ratio increased with increased oxygen consumption during exercise in normal myocardium but not in ischemic myocardium. The patient must exercise before fatty acid metabolism can be compared between normal and ischemic myocardium. (author)

  9. Myocardial fatty acid imaging using iodine-123-BMIPP in patients with hypertensive intracranial hemorrhage

    International Nuclear Information System (INIS)

    Hashizume, Toshikazu; Sakai, Yasuhito; Hayashi, Yasushi

    2000-01-01

    An evaluation of myocardial fatty acid metabolism in hypertensive patients with major complication has not been previously established. To assess the myocardial fatty acid metabolism in hypertensive patients with intracranial hemorrhage (IH), we performed myocardial image using 123 I-15-p-iodophenyl-3-methyl pentadecanoic acid (BMIPP). Seventeen hypertensive patients with IH (HIH) and 27 hypertensive patients without IH (HT) were studied. A dose of 111 MBq of BMIPP was injected intravenously at rest, and a myocardial image was recorded 30 minutes after the injection. Myocardial perfusion image using Thallium-201 (Tl) was also performed within 2 weeks after BMIPP study. The regional myocardial uptakes of BMIPP and Tl were visually assessed in 17 segments with a four-point scoring system (0=absent to 3=normal uptake). Cardiac hypertrophy was evaluated by electrocardiogrpahy (ECG) and two-dimensional ultrasonic cardiography (UCG). Sum of uptake scores of Tl was similar in both groups (45.1±5.4 vs. 47.9±4.2), but that of BMIPP in HIH was lower than HT (35.9±7.9 vs 45.6±4.8, p<0.001). Evaluation of cardiac hypertrophy using ECG and UCG revealed no significant difference between two groups. HIH have much more eccentric hypertrophy in UCG study than HT (53% vs. 37%). These data suggest that hypertensive patients with intracranial hemorrhage have a more impaired myocardial fatty acid metabolism compared to the hypertensive patients with similar cardiac hypertrophy. BMIPP imaging might be useful to evaluate the severity of myocardial fatty acid metabolism in hypertensive patients. (author)

  10. Evaluation of diffuse thyroid diseases by computed tomography and sup 123 I thyroidal uptake

    Energy Technology Data Exchange (ETDEWEB)

    Kurihara, Yoshiko (Saint Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine); Imanishi, Yoshimasa; Ehara, Norishige (and others)

    1991-10-01

    Understanding the iodine kinetics in the thyroid is useful for the diagnosis of a patient with diffuse thyroid disease. In this study, 9 controls and 50 patients with diffuse thyroid diseases, we evaluated diffuse thyroid diseases with {sup 123}I thyroidal uptake and volume, iodine concentration, and net iodine content measured by computed tomography. There was no significant correlation between volume, iodine concentration, and net iodine content of the thyroid and {sup 123}I thyroidal uptake. The thyroid volume in Graves' and Hashimoto's diseases was significantly larger than that in the control group. The thyroid iodine concentration in Graves' and Hashimoto's diseases was significantly smaller than that in the control group. The thyroid net iodine content in Hashimoto's disease was significantly smaller than that in the control group. Although most of the patients with Graves' disease had more increased radioiodine thyroidal uptake than the control group, there was no significant difference between them in the mean of the thyroid net iodine content. But the variance of net iodine contents in the former was significantly larger than that in the latter. The thyroid net iodine content was very low in all patients with very high thyroglobulin hemaggrugated antibody (TGHA) value although it was nearly normal in some patients with normal TGHA value. It was suggested that iodine concentration and net iodine content might be determined not only by iodine uptake but also by release and/or leakage of iodine compounds from the thyroid, which might depend on some antithyroid antibodies. (author).

  11. Improved iodine and tritium control in reprocessing plants

    International Nuclear Information System (INIS)

    Henrich, E.; Schmieder, H.; Roesch, W.; Weirich, F.

    1981-01-01

    During spent fuel processing, iodine and tritium are distributed in many aqueous, organic and gaseous process streams, which complicates their control. Small modifications of conventional purex flow sheets, compatible with processing in the headend and the first extraction cycle are necessary to confine the iodine and the tritium to smaller plant areas. The plant area connected to the dissolver off-gas (DOG) system is suited to confine the iodine and the plant area connected to the first aqueous cycle is suited to confine the tritium. A more clear and convenient iodine and tritium control will be achieved. Relevant process steps have been studied on a lab or a pilot plant scale using I-123 and H-3 tracer

  12. Comparison of chromatography and Sep-pak methods for estimating the radiochemical purity of I-123 and I-131 labelled meta-iodobenzylguanidine (mIBG), synthesised in house

    International Nuclear Information System (INIS)

    Kumar, V.

    1998-01-01

    Full text: Radioiodine (I-123 or I-131) labelled mlBG has been prepared routinely in-house in a number of radiopharmacy laboratories. The radiochemical purity can be estimated by several methods. Available literature suggests that the results of chronatographic analysis are comparable with electrophoresis and high pressure liquid chromatography (HPLC) methods which are considered as gold-standard procedures. However, due to the cost involved with these equipments most of the radiopharmacy laboratories are not fortunate enough to have them. The present study compares the validity of reverse-phase Sep-pak cartridge method against chromatographic technique. We analysed twenty four preparations of mIBG by both Sep-pak and chromatography methods (20 batches of I-123 mD3G and 4 batches of I-131 mIBG). Chromatographic analysis, which takes >2hrs, was performed with Whatman No 1/ n-butanol: acetic acid: water (60:15:25 v/v) and the activity associated with the peaks for free iodine and I-123 mD3G were measured. Sep-pak cartridge method, which takes less than 10 min, was performed as follows: the cartridge was activated by injecting 5 mL ethanol (200% pure) followed by flushing with 5mL distilled water. A sample (0.1mL) of radioiodine labelled mD3G was applied to the column and was eluted with 5mL distilled water. Subsequently two aliquots of 5mL solution containing tetrahydrofuran: (0.1M) sodium dihydrogen phosphate (25:75v/v) were passed through and the activity in each elute was measured. Analysing the results by Student's paired t-test for I-123 mlBG using the Sep-pak method gave a mean + SD of 98.8+ 0.6 % which correlated well (r 2 = 0.780) with the results obtained by the chromatographic method 99.3+0.5% (p <0.05). The results obtained for free I-123 by the two methods were 1.09 + 0.56% and 0.6 + 0.5% (p <0.05) respectively. The parameters did not differ significantly when I-131, instead of I-123, was used to synthesise mIBG. The results clearly indicate that the Sep

  13. Decrease in benzodiazepine receptor binding in a patient with Angelman syndrome detected by iodine-123 iomazenil and single-photon emission tomography

    International Nuclear Information System (INIS)

    Odano, Ikuo; Anezaki, Toshiharu; Ohkubo, Masaki; Yonekura, Yoshiharu; Onishi, Yoshihiro; Inuzuka, Takashi; Takahashi, Makoto; Tsuji, Shoji

    1996-01-01

    A receptor mapping technique using iodine-123 iomazenil and single-photon emission tomography (SPET) was employed to examine benzodiazepine receptor binding in a patient with Angelman syndrome (AS). AS is characterized by developmental delay, seizures, inappropriate laughter and ataxic movement. In this entity there is a cytogenic deletion of the proximal long arm of chromosome 15q11-q13, where the gene encoding the GABA A receptor β3 subunit (GABRB3) is located. Since the benzodiazepine receptor is constructed as a receptor-ionophore complex that contains the GABA A receptor, it is a suitable marker for GABA-ergic synapsis. To determine whether benzodiazepine receptor density, which indirectly indicates changes in GABA A receptor density, is altered in the brain in patients with AS, we investigated a 27-year-old woman with AS using 123 I-iomazenil and SPET. Receptor density was quantitatively assessed by measuring the binding potential using a simplified method. Regional cerebral blood flow was also measured with N-isopropyl-p- 123 iodoamphetamine. We demonstrated that benzodiazepiine receptor density is severely decreased in the cerebellum, and mildly decreased in the frontal and temporal cortices and basal ganglia, a result which is considered to indicate decreased GABA A receptor density in these regions. Although the deletion of GABRB3 was not observed in the present study, we indirectly demonstrated the disturbance of inhibitory neurotransmission mediated by the GABA A receptor in the investigated patient. 123 I-iomazenil with SPET was useful to map benzodiazepine receptors, which indicate GABA A receptor distribution and their density. (orig.)

  14. Multivariate cluster analysis of dynamic iodine-123 iodobenzamide SPET dopamine D{sub 2}receptor images in schizophrenia

    Energy Technology Data Exchange (ETDEWEB)

    Acton, P.D. [Inst. of Nuclear Medicine, Univ. Coll. London Medical School, London (United Kingdom); Pilowsky, L.S. [Institute of Psychiatry, London (United Kingdom); Costa, D.C. [Inst. of Nuclear Medicine, Univ. Coll. London Medical School, London (United Kingdom); Ell, P.J. [Inst. of Nuclear Medicine, Univ. Coll. London Medical School, London (United Kingdom)

    1997-02-01

    This paper describes the application of a multivariate statistical technique to investigate striatal dopamine D{sub 2}receptor concentrations measured by iodine-123 iodobenzamide ({sup 123}I-IBZM) single-photon emission tomography (SPET). This technique enables the automatic segmentation of dynamic nuclear medicine images based on the underlying time-activity curves present in the data. Once the time-activity curves have been extracted, each pixel can be mapped back on to the underlying distribution, considerably reducing image noise. Cluster analysis has been verified using computer simulations and phantom studies. The technique has been applied to SPET images of dopamine D {sub 2}receptors in a total of 20 healthy and 20 schizophrenic volunteers (22 male, 18 female), using the ligand {sup 123}I-IBZM. Following automatic image segmentation, the concentration of striatal dopamine D {sub 2}receptors shows a significant left-sided asymmetry in male schizophrenics compared with male controls. The mean left-minus-right laterality index for controls is -1.52 (95% CI -3.72-0.66) and for patients 4.04 (95% CI 1.07-7.01). Analysis of variance shows a case-by-sex-by-side interaction, with F=10.01, P=0.005. We can now demonstrate that the previously observed male sex-specific D {sub 2}receptor asymmetry in schizophrenia, which had failed to attain statistical significance, is valid. Cluster analysis of dynamic nuclear medicine studies provides a powerful tool for automatic segmentation and noise reduction of the images, removing much of the subjectivity inherent in region-of-interest analysis. The observed striatal D {sub 2}asymmetry could reflect long hypothesized disruptions in dopamine-rich cortico-striatal-limbic circuits in schizophrenic males. (orig.). With 4 figs., 2 tabs.

  15. Syntheses and biological evaluation of F-18 and I-123 labeled porphyrins as potential tumor imaging agents

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. H.; Ji, D. Y. [Inha University, Incheon (Korea, Republic of); Moon, B. S.; Lee, T. S.; Lee, D. H.; Lee, K. C.; Ahn, G. I.; Yang, S. D.; Choi, C. W.; Jun, K. S. [KIRAMS, Seoul (Korea, Republic of)

    2005-07-01

    Photofrin has currently been approved for general use by licensing authorities to treatment for solid tumor and cancer using photodynamic therapy (PDT) that treat to photochemical effect induced by light. Recently, meso-tetra(3-hydroxyphenyl)porphyrin has been developed as one of best tumor localizer and also shown a favorable tissue distribution. We have studied to develop I-123 labeled meso-tetra(3-methoxyphenyl)porphyrins for tumor imaging. We have studied to develop iodine-123 labeled meso-tetra(3-carboxymethoxy phenyl)porphyrin for tumor imaging agent. The radioiodinated porphyrin compound was obtained by the iodination reaction of tin precursor (50 ig) of porphyrin with Na-123I (200 {mu}L, 100-200 mCi), in the presence of peracetic acid (40 {mu}L) in ethanol. Iodine-123 labeled porphyrin derivative was obtained in 20-30% radiochemical yield and purified by HPLC at 2 mL/min using EtOH/water gradient condition and the fraction at 24-26 min was collected and characterized to desired compound by co injection with cold porphyrin analogue. Total time was around 120 min. The in vitro and in vivo of I-123 labeled porphyrin derivative is under studying.

  16. Syntheses and biological evaluation of F-18 and I-123 labeled porphyrins as potential tumor imaging agents

    International Nuclear Information System (INIS)

    Lee, J. H.; Ji, D. Y.; Moon, B. S.; Lee, T. S.; Lee, D. H.; Lee, K. C.; Ahn, G. I.; Yang, S. D.; Choi, C. W.; Jun, K. S.

    2005-01-01

    Photofrin has currently been approved for general use by licensing authorities to treatment for solid tumor and cancer using photodynamic therapy (PDT) that treat to photochemical effect induced by light. Recently, meso-tetra(3-hydroxyphenyl)porphyrin has been developed as one of best tumor localizer and also shown a favorable tissue distribution. We have studied to develop I-123 labeled meso-tetra(3-methoxyphenyl)porphyrins for tumor imaging. We have studied to develop iodine-123 labeled meso-tetra(3-carboxymethoxy phenyl)porphyrin for tumor imaging agent. The radioiodinated porphyrin compound was obtained by the iodination reaction of tin precursor (50 ig) of porphyrin with Na-123I (200 μL, 100-200 mCi), in the presence of peracetic acid (40 μL) in ethanol. Iodine-123 labeled porphyrin derivative was obtained in 20-30% radiochemical yield and purified by HPLC at 2 mL/min using EtOH/water gradient condition and the fraction at 24-26 min was collected and characterized to desired compound by co injection with cold porphyrin analogue. Total time was around 120 min. The in vitro and in vivo of I-123 labeled porphyrin derivative is under studying

  17. Some observations on the use of iodine-123 for thyroid imaging

    International Nuclear Information System (INIS)

    Ryo, U.Y.; Pinsky, S.

    1985-01-01

    Efficacy of /sup 99m/Tc and 123 I for thyroid imaging was studied in 122 subjects with a variety of thyroid abnormalities. Both agents produced images that were equivalent in quality in 51 subjects, the image with 123 I was in better quality in 22, and the /sup 99m/Tc image was better in 9. In the remaining 40 cases, discordant findings existed between the 123 I image and /sup 99m/Tc image. In the majority of cases, i.e., 32 or 40, the discrepancy was caused by hot or warm lesions on the /sup 99m/Tc image that became cold or normal (nonvisualization) on the 123 I image. Advantages with /sup 99m/Tc appeared to be (1) the saving of time and cost for patients and physicians and (2) superior sensitivity in detecting thyroid lesions, whereas the advantages with 123 I appeared to be better quality of thyroid images and accurate representation of function of thyroid nodules

  18. A rapid and efficient preparation of [{sup 123}I]radiopharmaceuticals using a small HPLC Rocket[reg] column

    Energy Technology Data Exchange (ETDEWEB)

    Katsifis, Andrew [Radiopharmaceuticals Division R and D, Australian Nuclear Science and Technology, Organisation, Menai, NSW 2234, Sydney (Australia)]. E-mail: akx@ansto.gov.au; Papazian, Vahan [Radiopharmaceuticals Division R and D, Australian Nuclear Science and Technology, Organisation, Menai, NSW 2234, Sydney (Australia); Jackson, Timothy [Radiopharmaceuticals Division R and D, Australian Nuclear Science and Technology, Organisation, Menai, NSW 2234, Sydney (Australia); Loc' h, Christian [Radiopharmaceuticals Division R and D, Australian Nuclear Science and Technology, Organisation, Menai, NSW 2234, Sydney (Australia)

    2006-01-01

    A simplified method for the rapid and efficient preparation of [{sup 123}I]radiopharmaceuticals is described. Three radiopharmaceuticals, [{sup 123}I]{beta}-CIT, [{sup 123}I]MIBG and [{sup 123}I]clioquinol, were synthesised and purified as model compounds. The radiotracers were labelled with iodine-123 using electrophilic oxidative conditions and purified by a compact semi-preparative reverse phase column (C-18, 3 {mu}m, 7x53 mm, Alltima Rocket[reg, Alltech] using aqueous-ethanol as HPLC solvents that were directly used for radiopharmaceutical formulation. The radiochemical purity of the radioiodinated tracers as assessed by analytical HPLC was higher than 99% with specific activity higher than 3 GBq/nmol. The total preparation time of a radiotracer ranged from 40 to 60 min and, starting from 3.7 GBq of iodine-123, more than 2.5 GBq of formulated radiopharmaceuticals were available for clinical investigations.

  19. Challenging the neuronal MIBG uptake by pharmacological intervention: effect of a single dose of oral amitriptyline on regional cardiac MIBG uptake

    Energy Technology Data Exchange (ETDEWEB)

    Estorch, Montserrat; Carrio, Ignasi; Mena, Esther; Flotats, Albert; Camacho, Valle; Fuertes, Jordi [Autonomous University of Barcelona, Department of Nuclear Medicine, Hospital Sant Pau, Barcelona (Spain); Kulisewsky, Jaume [Autonomous University of Barcelona, Department of Neurology, Hospital Sant Pau, Barcelona (Spain); Narula, Jagat [Irvine College of Medicine, Division of Cardiology, University of California, Irvine, CA (United States)

    2004-12-01

    Imaging with metaiodobenzylguanidine (MIBG) is used for the assessment of neuronal dysfunction in various cardiovascular disorders. Although valuable information is obtained by resting MIBG imaging, it is conceivable that competitive interference with the re-uptake mechanism would exaggerate MIBG defects and might unmask subclinical neuronal dysfunction. Tricyclic antidepressants, such as amitriptyline, have been reported to significantly increase cardiac MIBG washout and inhibit uptake into presynaptic neurons. This study was undertaken to assess whether a single oral dose of amitriptyline could influence cardiac MIBG distribution. Six patients (aged 62-81 years; four males, two females) who had demonstrated a normal cardiac MIBG scan during work-up for movement disorders were studied. The patients underwent a second {sup 123}I-MIBG study after oral administration of 25 mg amitriptyline within 1 week. Single-photon emission computed tomography images were acquired at 4 h to assess the regional distribution of MIBG, after generation of polar maps and employing a 20-segment model. Mean percentage of peak activity was calculated for each segment at rest and after amitriptyline administration. After amitriptyline administration, there was a decrease in regional MIBG uptake in 10{+-}4 segments per patient [62/120 segments (52%): 37 segments with a 5-10% decrease, 25 segments with a >10% decrease]. This change was statistically significant in lateral (P=0.003), apical (P<0.0001) and inferior (P=0.03) regions. A single oral dose of amitriptyline can induce changes in the uptake and retention of cardiac MIBG, indicating the feasibility of use of pharmacological intervention in cardiac neurotransmission imaging. (orig.)

  20. An estimation of the risk for the use of stable iodine in radiation protection in an iodine deficient population

    International Nuclear Information System (INIS)

    Gloebel, B.; Gloebel, H.; Muth, H.; Andres, C.

    1982-01-01

    The radiation risk of the thyroid is estimated by use of data from the literature and our investigations. Comparing these results with the statistical incidence of radiation evoked diseases the risk of a patient to develop thyroid carcinoma receiving 50 μCi 131 I for thyroid diagnostics is about tenfold compared to the spontaneous risk with a twofold risk to develop hypothyroidism. Using sup(99m)Tc or 123 I these risks are minimized to a small percentage. For technicians in the RIA lab or during labelling of proteins the thyroid's radiation risk can be diminished by ingestion of inactive iodine, however, this procedure includes new risks of iodine side-effects. Comparing the pharmacological risks of iodine intake and the radiation risk it seems to be useful to suggest iodine prophylaxis when the expected radiation dose exceeds 10 rad in the thyroid. (author)

  1. Thyroid disorders in mild iodine deficiency.

    Science.gov (United States)

    Laurberg, P; Nøhr, S B; Pedersen, K M; Hreidarsson, A B; Andersen, S; Bülow Pedersen, I; Knudsen, N; Perrild, H; Jørgensen, T; Ovesen, L

    2000-11-01

    Comparative epidemiologic studies in areas with low and high iodine intake and controlled studies of iodine supplementation have demonstrated that the major consequence of mild-to-moderate iodine deficiency for the health of the population is an extraordinarily high occurrence of hyperthyroidism in elderly subjects, especially women, with risk of cardiac arrhythmias, osteoporosis, and muscle wasting. The hyperthyroidism is caused by autonomous nodular growth and function of the thyroid gland and it is accompanied by a high frequency of goiter. Pregnant women and small children are not immediately endangered but the consequences of severe iodine deficiency for brain development are grave and a considerable safety margin is advisable. Moreover, a shift toward less malignant types of thyroid cancer and a lower radiation dose to the thyroid in case of nuclear fallout support that mild-to-moderate iodine deficiency should be corrected. However, there is evidence that a high iodine intake may be associated with more autoimmune hypothyroidism, and that Graves' disease may manifest at a younger age and be more difficult to treat. Hence, the iodine intake should be brought to a level at which iodine deficiency disorders are avoided but not higher. Iodine supplementation programs should aim at relatively uniform iodine intake, avoiding deficient or excessive iodine intake in subpopulations. To adopt such a strategy, surveillance programs are needed.

  2. Iodine-123 labelled Z-(R,R)-IQNP: a potential radioligand for visualization of M{sub 1} and M{sub 2} muscarinic acetylcholine receptors in Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Bergstroem, K.A. [Dept. of Clinical Neuroscience, Psychiatry and Nuclear Medicine Sections, Karolinska Institutet, Karolinska Hospital, Stockholm (Sweden); Clinical Physiology and Nuclear Medicine, Kuopio University Hospital, Kuopio (Finland); Halldin, C.; Okubo, Yoshiro; Nobuhara, Kenji; Swahn, C.G.; Karlsson, P.; Larsson, S.; Schnell, P.O.; Farde, L. [Dept. of Clinical Neuroscience, Psychiatry and Nuclear Medicine Sections, Karolinska Institutet, Karolinska Hospital, Stockholm (Sweden); Savonen, A.; Hiltunen, Jukka [MAP Medical Technologies Oy, Tikkakoski (Finland); McPherson, D.; Knapp, F.F. Jr. [Nuclear Medicine Group, Oak Ridge National Laboratory (ORNL), TN (United States)

    1999-11-01

    Z-(R)-1-Azabicyclo[2.2.2]oct-3-yl (R)-{alpha}-hydroxy-{alpha}-(1-iodo-1-propen-3-yl)-{alpha}-phenylacetate (Z-IQNP) has high affinity to the M{sub 1}and M {sub 2} muscarinic acetylcholine receptor (mAChR) subtypes according to previous in vitro and in vivo studies in rats. In the present study iodine-123 labelled Z-IQNP was prepared for in vivo single-photon emission tomography (SPET) studies in cynomolgus monkeys. SPET studies with Z-[ {sup 123}I]IQNP demonstrated high accumulation in monkey brain (>5% of injected dose at 70 min p.i.) and marked accumulation in brain regions such as the thalamus, the neocortex, the striatum and the cerebellum. Pretreatment with the non-selective mAChR antagonist scopolamine (0.2 mg/kg) inhibited Z-[ {sup 123}I]IQNP binding in all these regions. The percentage of unchanged Z-[ {sup 123}I]IQNP measured in plasma was less than 10% at 10 min after injection, which may be due to rapid hydrolysis, as has been demonstrated previously with the E-isomer of IQNP. Z-[ {sup 123}I]IQNP showed higher uptake in M {sub 2}-rich regions, compared with previously obtained results with E-[ {sup 123}I]IQNP. In conclusion, the radioactivity distribution from Z-[ {sup 123}I]IQNP in monkey brain indicates that Z-[ {sup 123}I]IQNP binds to the M {sub 1}- and M {sub 2}-rich areas and provides a high signal for specific binding, and is thus a potential ligand for mAChR imaging with SPET. (orig.)

  3. Brain 18F-FDG, 18F-florbtaben PET/CT, 123I-FP-CIT SPECT and cardiac 123I-MBG imaging for diagnosis of a 'cerebral type' of Lewy Body disease

    International Nuclear Information System (INIS)

    Gucht, Axel Van Der; Bélissant, Ophélie; Rabu, Corenti; Cottereau, Anne-Ségolène; Evangelista, Eva; Chalaye, Julia; Bonnot-Lours, Sophie; Fénelon, Gilles; Itti, Emmanuel; De Langavant, Laurent Cleret

    2016-01-01

    A 67-year-old man was referred for fluctuating neuropsychiatric symptoms, featuring depression, delirious episodes, recurrent visual hallucinations and catatonic syndrome associated with cognitive decline. No parkinsonism was found clinically even under neuroleptic treatment. 18 F-FDG PET/CT showed hypometabolism in the posterior associative cortex including the occipital cortex, suggesting Lewy body dementia, but 123 I-FP-CIT SPECT was normal and cardiac 123 I-MIBG imaging showed no signs of sympathetic denervation. Alzheimer's disease was excluded by a normal 18 F-florbetaben PET/CT. This report suggests a rare case of α-synucleinopathy without brainstem involvement, referred to as 'cerebral type' of Lewy body disease

  4. Synthesis of the 123I- and 125I-labeled cholinergic nerve marker (-)-5-iodobenzovesamicol

    International Nuclear Information System (INIS)

    Van Dort, M.E.; Jung, Y.-W.; Gildersleeve, D.L.; Hagen, C.A.; Kuhl, D.E.; Wieland, D.M.

    1993-01-01

    The highly toxic curaremimetic and cholinergic neuron marker (-)-5-iodobenzovesamicol (IBVM) has been labeled with iodine-125 and iodine-123. [ 125 I]IBVM, suitable for animal distribution and ex vivo autoradiographic studies, was synthesized by solid-state exchanger; isolated yields were 65-89% with specific activities in the range of 130-200 Ci/mmol. The synthesis of no-carrier-added (-)-5-[ 125 I]IBVM from the corresponding chiral (-)-5-(tri-n-butyltin) derivative using Na 125 I was evaluated using the oxidants H 2 O 2 , peracetic acid and chloramine-T. Both peracetic acid and chloramine-T gave good yields (70-95%). However, when Na 123 I was utilized, acceptable yields of [ 123 I]IBVM were obtained only with chloramine-T. Distribution analyses of [ 125 I]IBVM and [ 123 I]IBVM in mice 4 h following intravenous administration show essentially equivalent concentrations of the two tracers in the four brain regions sampled. The exceptionally high specific activity of [ 123 I]IBVM has made possible the evaluation of this radiotracer in humans. (Author)

  5. Comparative value of brain perfusion SPECT and [123I]MIBG myocardial scintigraphy in distinguishing between dementia with Lewy bodies and Alzheimer's disease

    International Nuclear Information System (INIS)

    Hanyu, Haruo; Shimizu, Soichiro; Hirao, Kentaro; Kanetaka, Hidekazu; Iwamoto, Toshihiko; Chikamori, Taishiro; Usui, Yasuhiro; Yamashina, Akira; Koizumi, Kiyoshi; Abe, Kimihiko

    2006-01-01

    Both decreased occipital perfusion on brain single-photon emission computed tomography (SPECT) and reduction in cardiac 123 I-metaiodobenzylguanidine (MIBG) uptake are characteristic features of dementia with Lewy bodies (DLB), and potentially support the clinical diagnosis of DLB. The aim of this study was to compare the diagnostic value of these two methods for differentiation of DLB from Alzheimer's disease (AD). The study population comprised 19 patients with probable DLB and 39 patients with probable AD who underwent both SPECT with N-isopropyl-p-[ 123 I]iodoamphetamine and MIBG myocardial scintigraphy. Objective and quantitative measurement of perfusion in the medial occipital lobe, including the cuneus and lingual gyrus, was performed by the use of three-dimensional stereotactic surface projections. Medial occipital perfusion was significantly decreased in the DLB group compared with the AD group. The mean heart/mediastinum ratios of MIBG uptake were significantly lower in the DLB group than in the AD group. Although SPECT failed to demonstrate significant hypoperfusion in the medial occipital lobe in five patients with DLB, marked reduction of MIBG uptake was found in all patients with DLB. Receiver operating characteristic analysis revealed that MIBG myocardial scintigraphy enabled more accurate discrimination between DLB and AD than was possible with perfusion SPECT. MIBG myocardial scintigraphy may improve the sensitivity in the detection of DLB. In particular, this method may provide a powerful differential diagnostic tool when it is difficult to distinguish cases of DLB from AD using brain perfusion SPECT. (orig.)

  6. Evaluation of cardiac sympathetic nerve activity and aldosterone suppression in patients with acute decompensated heart failure on treatment containing intravenous atrial natriuretic peptide

    International Nuclear Information System (INIS)

    Kasama, Shu; Toyama, Takuji; Kurabayashi, Masahiko; Iwasaki, Toshiya; Sumino, Hiroyuki; Kumakura, Hisao; Minami, Kazutomo; Ichikawa, Shuichi; Matsumoto, Naoya; Nakata, Tomoaki

    2014-01-01

    Aldosterone prevents the uptake of norepinephrine in the myocardium. Atrial natriuretic peptide (ANP), a circulating hormone of cardiac origin, inhibits aldosterone synthase gene expression in cultured cardiocytes. We evaluated the effects of intravenous ANP on cardiac sympathetic nerve activity (CSNA) and aldosterone suppression in patients with acute decompensated heart failure (ADHF). We studied 182 patients with moderate nonischemic ADHF requiring hospitalization and treated with standard therapy containing intravenous ANP and 10 age-matched normal control subjects. ANP was continuously infused for >96 h. In all subjects, delayed total defect score (TDS), heart to mediastinum ratio, and washout rate were determined by 123 I-metaiodobenzylguanidine (MIBG) scintigraphy. Left ventricular (LV) end-diastolic volume, end-systolic volume, and ejection fraction were determined by echocardiography. All patients with acute heart failure (AHF) were examined once within 3 days and then 4 weeks after admission, while the control subjects were examined only once (when their hemodynamics were normal). Moreover, for 62 AHF patients, plasma aldosterone concentrations were measured at admission and 1 h before stopping ANP infusion. 123 I-MIBG scintigraphic and echocardiographic parameters in normal subjects were more favorable than those in patients with AHF (all p < 0.001). After treatment, all these parameters improved significantly in AHF patients (all p < 0.001). We also found significant correlation between percent changes of TDS and aldosterone concentrations (r = 0.539, p < 0.001) in 62 AHF patients. The CSNA and LV performance were all improved in AHF patients. Furthermore, norepinephrine uptake of myocardium may be ameliorated by suppressing aldosterone production after standard treatment containing intravenous ANP. (orig.)

  7. Myocardial impairment detected by late gadolinium enhancement in hypertrophic cardiomyopathy: comparison with 99mTc-MIBI/tetrofosmin and 123I-BMIPP SPECT.

    Science.gov (United States)

    Hashimura, Hiromi; Kiso, Keisuke; Yamada, Naoaki; Kono, Atsushi; Morita, Yoshiaki; Fukushima, Kazuto; Higashi, Masahiro; Noguchi, Teruo; Ishibashi-Ueda, Hatsue; Naito, Hiroaki; Sugimura, Kazuro

    2013-06-17

    Myocardial fibrosis is considered to be an important factor in myocardial dysfunction and sudden cardiac death in hypertrophic cardiomyopathy (HCM). The purpose of this study was to compare myocardial fibrosis detected by late gadolinium enhancement (LGE) on cardiac MRI with myocardial perfusion and fatty acid metabolism assessed by single photon emission computed tomography in HCM. We retrospectively evaluated 20 consecutive HCM patients (female, 7; mean age, 53.4 years) who underwent LGE, technetium-99m methoxyisobutylisonitrile/tetrofosmin (99mTc-MIBI/tetrofosmin), and iodine-123 beta-methyl-iodophenylpentadecanoic acid (123I-BMIPP) imaging. We calculated the myocardium-to-lumen signal ratio (M/L) for LGE in 17 segments based on the American Heart Association statement. Scoring of 99mTc-MIBI/tetrofosmin (PI) and 123I-BMIPP (BM) was performed for each segment using a 5-point scale (0, normal; 4, highly decreased). Nineteen of 20 patients (95%) and 153 of 340 segments (45%) showed LGE. M/Ls were 0.42±0.16, 0.55±0.17, and 0.65±0.24 in PI0/BM0, PI0/BM1-4 and PI1-4/BM1-4, respectively. All M/Ls were significantly higher than that of a normal control (0.34±0.14) (pacid metabolism, and is more strongly associated with disorders of fatty acid metabolism than with perfusion abnormalities. M/L may be a useful indicator of disease severity.

  8. Microvascular obstruction on delayed enhancement cardiac magnetic resonance imaging after acute myocardial infarction, compared with myocardial {sup 201}Tl and {sup 123}I-BMIPP dual SPECT findings

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Hiroaki [Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya (Japan); Department of Cardiology, Kainan Hospital, Yatomi (Japan); Isobe, Satoshi, E-mail: sisobe@med.nagoya-u.ac.jp [Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya (Japan); Sakai, Shinichi [Department of Cardiology, Kainan Hospital, Yatomi (Japan); Yamada, Takashi [Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya (Japan); Watanabe, Naoki; Miura, Manabu [Department of Cardiology, Kainan Hospital, Yatomi (Japan); Uchida, Yasuhiro; Kanashiro, Masaaki; Ichimiya, Satoshi [Department of Cardiology, Yokkaichi Municipal Hospital, Yokkaichi (Japan); Okumura, Takahiro; Murohara, Toyoaki [Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya (Japan)

    2015-08-15

    Highlights: • The percentage infarct size (%IS) was significantly greater in the microvascular obstruction (MO) group than in the non-MO group. • The percentage mismatch score (%MMS) on dual scintigraphy significantly correlated with the %IS and the percentage MO. • The %MMS was significantly greater in the non-MO group than in the MO group, and was an independent predictor for MO. - Abstract: Background: The hypo-enhanced regions within the hyper-enhanced infarct areas detected by cardiac magnetic resonance (CMR) imaging reflect microvascular obstruction (MO) after acute myocardial infarction (AMI). The combined myocardial thallium-201 ({sup 201}Tl)/iodine-123-15-(p-iodophenyl)-3-(R,S)-methylpentadecanoic acid ({sup 123}I-BMIPP) dual single-photon emission computed tomography (SPECT) is a useful tool for detecting myocardial reversibility after AMI. We evaluated whether MO could be an early predictor of irreversible myocardial damage in comparison with {sup 201}Tl and {sup 123}I-BMIPP dual SPECT findings in AMI patients. Methods: Sixty-two patients with initial AMI who successfully underwent coronary revascularization were enrolled. MO was defined by CMR imaging. Patients were divided into 2 groups as follows: MO group (n = 32) and non-MO group (n = 30). Scintigraphic defect scores were calculated using a 17-segment model with a 5-point scoring system. The mismatch score (MMS) was calculated as follows: the total sum of (Σ) {sup 123}I-BMIPP defect score minus Σ{sup 201}Tl defect score. The percentage mismatch score (%MMS) was calculated as follows: MMS/(Σ{sup 123}I-BMIPP score) × 100 (%). Results: The percentage infarct size (%IS) was significantly greater in the MO group than in the non-MO group (32.2 ± 13.8% vs. 18.3 ± 12.1%, p < 0.001). The %MMS significantly correlated with the %IS and the percentage MO (r = −0.26, p = 0.03; r = −0.45, p < 0.001, respectively). The %MMS was significantly greater in the non-MO group than in the MO group (45.4

  9. Association between left ventricular regional sympathetic denervation and mechanical dyssynchrony in phase analysis: a cardiac CZT study

    Energy Technology Data Exchange (ETDEWEB)

    Gimelli, Alessia; Genovesi, Dario; Giorgetti, Assuero; Kusch, Annette [Fondazione Toscana Gabriele Monasterio, Pisa (Italy); Liga, Riccardo [Scuola Superiore Sant' Anna, Pisa (Italy); Marzullo, Paolo [Fondazione Toscana Gabriele Monasterio, Pisa (Italy); CNR, Institute of Clinical Physiology, Pisa (Italy)

    2014-05-15

    To evaluate the relationships among myocardial sympathetic innervation, perfusion and mechanical synchronicity assessed with cardiac cadmium-zinc-telluride (CZT) scintigraphy. A group of 29 patients underwent an evaluation of myocardial perfusion with {sup 99m}Tc-tetrofosmin CZT scintigraphy and adrenergic innervation with {sup 123}I-metaiodobenzylguanidine (MIBG) CZT scintigraphy. The summed rest score (SRS), motion score (SMS) and thickening score (STS), as well as the summed {sup 123}I-MIBG defect score (SS-MIBG), were determined. Regional tracer uptake for both {sup 99m}Tc-tetrofosmin and {sup 123}I-MIBG was also calculated. Finally, the presence of significant myocardial mechanical dyssynchrony was evaluated in phase analysis on gated CZT images and the region of latest mechanical activation identified. Significant mechanical dyssynchrony was present in 17 patients (59 %) and associated with higher SRS (P = 0.030), SMS (P < 0.001), STS (P = 0.003) and early SS-MIBG (P = 0.037) as well as greater impairments in left ventricular ejection fraction (P < 0.001) and end-diastolic volume (P < 0.001). In multivariate analysis a higher end-diastolic volume remained the only predictor of mechanical dyssynchrony (P = 0.047). Interestingly, while in the whole population regional myocardial perfusion and adrenergic activity were strongly correlated (R = 0.68), in patients with mechanical dyssynchrony the region of latest mechanical activation was predicted only by greater impairment in regional {sup 123}I-MIBG uptake (P = 0.012) that overwhelmed the effect of depressed regional perfusion. Left ventricular mechanical dyssynchrony is associated with greater depression in contractile function and greater impairments in regional myocardial perfusion and sympathetic activity. In patients with dyssynchrony, the region of latest mechanical activation is characterized by a significantly altered adrenergic tone. (orig.)

  10. Clinical experience with iodine-123-iodophenylpentadecanoic acid.

    Science.gov (United States)

    Corbett, J

    1994-04-01

    Initial research in dogs and later research in normal volunteers and patients with coronary artery disease indicated that 123I-iodophenylpentadecanoic acid (IPPA) can provide valuable diagnostic information. This agent compared favorably to 201Tl in detecting stenosed coronary arteries and identified reversible lesions with greater frequency. Testing with both 201Tl and IPPA before and after percutaneous transluminal coronary angioplasty produced similar results, supporting the notion that IPPA deserves inclusion among the diagnostic tools used to evaluate coronary heart disease.

  11. Subjective and objective image differences in pediatric computed tomography cardiac angiography using lower iodine concentration

    International Nuclear Information System (INIS)

    Hwang, Jae-Yeon; Choo, Ki Seok; Choi, Yoon Young; Kim, Jin Hyeok; Ryu, Hwaseong; Kim, Yong-Woo; Jeon, Ung Bae; Nam, Kyung Jin; Han, Junhee

    2017-01-01

    Several recent studies showed the optimal contrast enhancement with a low-concentration and iso-osmolar contrast media in both adult and pediatric patients. However, low contrast media concentrations are not routinely used due to concerns of suboptimal enhancement of cardiac structures and small vessels. To evaluate the feasibility of using iso-osmolar contrast media containing a low iodine dose for CT cardiac angiography at 80 kilovolts (kVp) in neonates and infants. The iodixanol 270 group consisted of 79 CT scans and the iopromide 370 group of 62 CT scans in patients ≤1 year old. Objective measurement of the contrast enhancement was analyzed and contrast-to-noise ratios of the ascending aorta and left ventricle were calculated. Regarding subjective measurement, a four-point scale system was devised to evaluate degrees of contrast enhancement, image noise, motion artifact and overall image quality of each image set. Reader performance for correctly differentiating iodixanol 270 and iopromide 370 by visual assessment was evaluated. Group objective and subjective measurements were nonsignificantly different. Overall sensitivity, specificity and diagnostic accuracy for correctly differentiating iodixanol 270 and iopromide 370 by visual assessment were 42.8%, 59%, and 50%, respectively. The application of iodixanol 270 achieved optimal enhancement for performing pediatric cardiac CT angiography at 80 kVp in neonates and infants. Objective measurements of contrast enhancement and subjective image quality assessments were not statistically different in the iodixanol 270 and iopromide 370 groups. (orig.)

  12. Subjective and objective image differences in pediatric computed tomography cardiac angiography using lower iodine concentration

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jae-Yeon [Pusan National University Yangsan Hospital, Department of Radiology, Yangsan-si, Gyeongsangnam-do (Korea, Republic of); Pusan National University Yangsan Hospital, Research Institute for Convergence of Biomedical Science and Technology, Yangsan-si, Gyeongsangnam-do (Korea, Republic of); Choo, Ki Seok; Choi, Yoon Young; Kim, Jin Hyeok; Ryu, Hwaseong; Kim, Yong-Woo; Jeon, Ung Bae; Nam, Kyung Jin [Pusan National University Yangsan Hospital, Department of Radiology, Yangsan-si, Gyeongsangnam-do (Korea, Republic of); Han, Junhee [Pusan National University Yangsan Hospital, Division of Biostatistics, Research Institute for Convergence of Biomedical Science and Technology, Yangsan-si, Gyeongsangnam-do (Korea, Republic of)

    2017-05-15

    Several recent studies showed the optimal contrast enhancement with a low-concentration and iso-osmolar contrast media in both adult and pediatric patients. However, low contrast media concentrations are not routinely used due to concerns of suboptimal enhancement of cardiac structures and small vessels. To evaluate the feasibility of using iso-osmolar contrast media containing a low iodine dose for CT cardiac angiography at 80 kilovolts (kVp) in neonates and infants. The iodixanol 270 group consisted of 79 CT scans and the iopromide 370 group of 62 CT scans in patients ≤1 year old. Objective measurement of the contrast enhancement was analyzed and contrast-to-noise ratios of the ascending aorta and left ventricle were calculated. Regarding subjective measurement, a four-point scale system was devised to evaluate degrees of contrast enhancement, image noise, motion artifact and overall image quality of each image set. Reader performance for correctly differentiating iodixanol 270 and iopromide 370 by visual assessment was evaluated. Group objective and subjective measurements were nonsignificantly different. Overall sensitivity, specificity and diagnostic accuracy for correctly differentiating iodixanol 270 and iopromide 370 by visual assessment were 42.8%, 59%, and 50%, respectively. The application of iodixanol 270 achieved optimal enhancement for performing pediatric cardiac CT angiography at 80 kVp in neonates and infants. Objective measurements of contrast enhancement and subjective image quality assessments were not statistically different in the iodixanol 270 and iopromide 370 groups. (orig.)

  13. Discrepant uptake of the radiolabeled norepinephrine analogues hydroxyephedrine (HED) and metaiodobenzylguanidine (MIBG) in rat hearts

    Energy Technology Data Exchange (ETDEWEB)

    Rischpler, Christoph [Johns Hopkins University, Division of Nuclear Medicine, The Russell H. Morgan Department of Radiology, Baltimore, MD (United States); Klinikum rechts der Isar, Nuklearmedizinische Klinik und Poliklinik, Munich (Germany); Fukushima, Kenji; Isoda, Takuro; Javadi, Mehrbod S.; Dannals, Robert F.; Wahl, Richard [Johns Hopkins University, Division of Nuclear Medicine, The Russell H. Morgan Department of Radiology, Baltimore, MD (United States); Abraham, Roselle [Johns Hopkins University, Division of Cardiology, Department of Medicine, Baltimore, MD (United States); Bengel, Frank M. [Johns Hopkins University, Division of Nuclear Medicine, The Russell H. Morgan Department of Radiology, Baltimore, MD (United States); Hannover Medical School, Department of Nuclear Medicine, Hannover (Germany); Higuchi, Takahiro [Johns Hopkins University, Division of Nuclear Medicine, The Russell H. Morgan Department of Radiology, Baltimore, MD (United States); Wuerzburg University, CHFC/Department of Nuclear Medicine, Wuerzburg (Germany); Universitaetsklinikum Wuerzburg, Nuklearmedizinische Klinik und Poliklinik, Wuerzburg (Germany)

    2013-07-15

    {sup 11}C-Hydroxyephedrine (HED) and radioiodinated metaiodobenzylguanidine ({sup 123}I/{sup 131}I-MIBG) are catecholamine analogue tracers for sympathetic nerve positron emission tomography/single photon emission computed tomography (PET/SPECT) imaging. In contrast to humans, rat hearts demonstrate high nonneural catecholamine uptake-2 in addition to neural uptake-1, the contributions of which to tracer accumulation are not fully elucidated. Wistar rats were studied using the following pretreatments: uptake-1 blockade with desipramine 2 mg/kg IV, both uptake-1 and -2 blockade with phenoxybenzamine 50 mg/kg IV, or control with saline IV. HED or {sup 123}I-MIBG was injected 10 min after pretreatment, and rats were sacrificed 10 min later. Heart to blood tissue count ratio (H/B ratio) was obtained using a gamma counter. To determine regional tracer uptake, dual-tracer autoradiography was performed with HED and {sup 131}I-MIBG in Wistar rats with chronic infarction by transient coronary occlusion and reperfusion and in healthy control rats. Local tracer distributions were analyzed, and the infarcted rats' local tracer distributions were compared with histology. The H/B ratios in control hearts were 34.4 {+-} 1.7 and 25.5 {+-} 2.1 for HED and {sup 123}I-MIBG, respectively. Desipramine led to a significant decrease in HED (3.2 {+-} 0.5, p < 0.0001), while there was no change in {sup 123}I-MIBG (25.5 {+-} 6.4, p = n.s.). Phenoxybenzamine led to a significant decrease in both HED and {sup 123}I-MIBG (3.5 {+-} 0.02, 4.3 {+-} 0.7, p < 0.0001). Only HED showed a subepicardium-subendocardium gradient in healthy control hearts which is consistent with physiological innervation, while {sup 131}I-MIBG was evenly distributed throughout the myocardium. {sup 131}I-MIBG uptake defect closely matched the scar area determined by histology [3.8 {+-} 2.3 % ({sup 131}I-MIBG defect) vs 4.0 {+-} 2.4 % (scar)]. However, the scar area was clearly exceeded by the HED uptake defect (9

  14. Reproducibility of [123I]PE2I binding to dopamine transporters with SPECT

    DEFF Research Database (Denmark)

    Ziebell, Morten; Thomsen, Gerda; Knudsen, Gitte M

    2007-01-01

    The iodinated cocaine derivative [(123)I]PE2I is a new selective ligand for in vivo studies of the dopamine transporter (DAT) with SPECT. Recently, a bolus/infusion (B/I) protocol for [(123)I]PE2I measurements of DAT density was established [Pinborg LH et al. J Nucl Med 2005;46:1119-271]. The aims...

  15. Synthesis of N-isopropyl p-[123I]iodoamphetamine via organoborane chemistry

    International Nuclear Information System (INIS)

    Kabalka, G.W.; Varma, R.S.; Gai, Y.

    1990-01-01

    Iodine-123 labeled amphetamines have proven to be excellent cerebral perfusion tracers. The radioiodination of aromatic amines is generally achieved via high temperature substitution reactions which are prone to side reactions. The authors report that N-isopropyl p-[ 123 I]iodoamphetamine, and other iodophenylamines, are readily synthesized from the corresponding air stable, boronic acids. The reaction is based on the no-carrier-added radioiodination sequence developed in their laboratory

  16. Thyroid disorders in mild iodine deficiency

    DEFF Research Database (Denmark)

    Laurberg, P; Nøhr, S B; Pedersen, K M

    2000-01-01

    in elderly subjects, especially women, with risk of cardiac arrhythmias, osteoporosis, and muscle wasting. The hyperthyroidism is caused by autonomous nodular growth and function of the thyroid gland and it is accompanied by a high frequency of goiter. Pregnant women and small children are not immediately...... endangered but the consequences of severe iodine deficiency for brain development are grave and a considerable safety margin is advisable. Moreover, a shift toward less malignant types of thyroid cancer and a lower radiation dose to the thyroid in case of nuclear fallout support that mild-to-moderate iodine...

  17. I-123 metaiodobenzylguanidine cardiac scintigraphy in patients with an implanted permanent pacemaker

    International Nuclear Information System (INIS)

    Nakata, Akio; Hirota, Satoshi; Tsuji, Hiroshi; Takazakura, Eisuke

    1995-01-01

    Tl scintigraphic abnormalities have been reported in patients with an implanted permanent pacemaker, but little is known about the MIBG scintigraphic findings in such patients. This study was performed to assess the MIBG scintigraphic findings in patients with an implanted permanent pacemaker, and to test the hypothesis that imaging characteristics of MIBG scintigraphy differ according to its mode. Twelve patients (4 men and 8 women, mean age: 72.4±9.5 years), who had undergone the implantation of a permanent pacemaker for bradyarrhythmias, underwent MIBG scintigraphy. The patients were divided into VVI pacemaker and DDD pacemaker groups. The tomograms were divided into nine segments and the MIBG defect in each segment scored on a scale ranging from 0 (normal uptake) to 3 (no uptake). Total MIBG defect scores were generated by summing the scores for the nine segments in each patient. MIBG scintigraphic abnormalities were found in ten of the twelve patients. The six patients with the VVI pacemaker manifested MIBG scintigraphic abnormalities. These MIBG scintigraphic abnormalities were observed in all segments, particularly in the posterior segments. The mean total defect score of the VVI group was higher than that of the DDD group (14.8±9.8 vs 3.0±3.5, respectively p<0.05). Therefore, we conclude that despite several limitations of the study, MIBG scintigraphic abnormalities occur in patients with implanted permanent pacemakers, and that such abnormalities are more prominent with the VVI than DDD pacemaker. (author)

  18. Significance of cardiac sympathetic nervous system abnormality for predicting vascular events in patients with idiopathic paroxysmal atrial fibrillation

    International Nuclear Information System (INIS)

    Akutsu, Yasushi; Kaneko, Kyouichi; Kodama, Yusuke; Li, Hui-Ling; Kawamura, Mitsuharu; Asano, Taku; Hamazaki, Yuji; Tanno, Kaoru; Kobayashi, Youichi; Suyama, Jumpei; Shinozuka, Akira; Gokan, Takehiko

    2010-01-01

    Neuronal system activity plays an important role for the prognosis of patients with atrial fibrillation (AF). Using 123 I metaiodobenzylguanidine ( 123 I-MIBG) scintigraphy, we investigated whether a cardiac sympathetic nervous system (SNS) abnormality would be associated with an increased risk of vascular events in patients with paroxysmal AF. 123 I-MIBG scintigraphy was performed in 69 consecutive patients (67 ± 13 years, 62% men) with paroxysmal AF who did not have structural heart disease. SNS integrity was assessed from the heart to mediastinum (H/M) ratio on delayed imaging. Serum concentration of C-reactive protein (CRP) was measured before 123 I-MIBG study. During a mean of 4.5 ± 3.6 years follow-up, 19 patients had myocardial infarction, stroke or heart failure (range: 0.2-11.5 years). SNS abnormality (H/M ratio <2.7) and high CRP (≥0.3 mg/dl) were associated with the vascular events (58.3% in 14 of 24 patients with SNS abnormality vs 11.1% in 5 of 45 patients without SNS abnormality, p < 0.0001, 52.4% in 11 of 21 patients with high CRP vs 16.7% in 8 of 48 patients without high CRP, p < 0.0001). After adjustment for potential confounding variables such as age, left atrial dimension and left ventricular function, SNS abnormality was an independent predictor of vascular events with a hazard ratio of 4.1 [95% confidence interval (CI): 1.3-12.6, p = 0.014]. Further, SNS abnormality had an incremental and additive prognostic power in combination with high CRP with an adjusted hazard ratio of 4.1 (95% CI: 1.5-10.9, p = 0.006). SNS abnormality is predictive of vascular events in patients with idiopathic paroxysmal AF. (orig.)

  19. Significance of cardiac sympathetic nervous system abnormality for predicting vascular events in patients with idiopathic paroxysmal atrial fibrillation

    Energy Technology Data Exchange (ETDEWEB)

    Akutsu, Yasushi; Kaneko, Kyouichi; Kodama, Yusuke; Li, Hui-Ling; Kawamura, Mitsuharu; Asano, Taku; Hamazaki, Yuji; Tanno, Kaoru; Kobayashi, Youichi [Showa University School of Medicine, Division of Cardiology, Department of Medicine, Tokyo (Japan); Suyama, Jumpei; Shinozuka, Akira; Gokan, Takehiko [Showa University School of Medicine, Department of Radiology, Tokyo (Japan)

    2010-04-15

    Neuronal system activity plays an important role for the prognosis of patients with atrial fibrillation (AF). Using {sup 123}I metaiodobenzylguanidine ({sup 123}I-MIBG) scintigraphy, we investigated whether a cardiac sympathetic nervous system (SNS) abnormality would be associated with an increased risk of vascular events in patients with paroxysmal AF. {sup 123}I-MIBG scintigraphy was performed in 69 consecutive patients (67 {+-} 13 years, 62% men) with paroxysmal AF who did not have structural heart disease. SNS integrity was assessed from the heart to mediastinum (H/M) ratio on delayed imaging. Serum concentration of C-reactive protein (CRP) was measured before {sup 123}I-MIBG study. During a mean of 4.5 {+-} 3.6 years follow-up, 19 patients had myocardial infarction, stroke or heart failure (range: 0.2-11.5 years). SNS abnormality (H/M ratio <2.7) and high CRP ({>=}0.3 mg/dl) were associated with the vascular events (58.3% in 14 of 24 patients with SNS abnormality vs 11.1% in 5 of 45 patients without SNS abnormality, p < 0.0001, 52.4% in 11 of 21 patients with high CRP vs 16.7% in 8 of 48 patients without high CRP, p < 0.0001). After adjustment for potential confounding variables such as age, left atrial dimension and left ventricular function, SNS abnormality was an independent predictor of vascular events with a hazard ratio of 4.1 [95% confidence interval (CI): 1.3-12.6, p = 0.014]. Further, SNS abnormality had an incremental and additive prognostic power in combination with high CRP with an adjusted hazard ratio of 4.1 (95% CI: 1.5-10.9, p = 0.006). SNS abnormality is predictive of vascular events in patients with idiopathic paroxysmal AF. (orig.)

  20. Cardiac abnormalities in diabetic patients with mutation in the mitochondrial tRNA Leu(UUR)Gene

    International Nuclear Information System (INIS)

    Ueno, Hiroshi; Shiotani, Hideyuki

    1999-01-01

    An A-to-G transition at position 3243 of the mitochondrial DNA is known to be a pathogenic factor for mitochondrial myopathy, encephalopathy, lactic acidosis and stroke-like episodes (MELAS), diabetes and cardiomyopathy. This mutation causes dysfunction of the central nervous system in MELAS. Because the heart, as well as the brain and nervous system, is highly dependent on the energy produced by mitochondrial oxidation, these tissues are more vulnerable to mitochondrial defects. Cardiac abnormalities were assessed in 10 diabetic patients associated with this mutation using echocardiography and 123 I-metaiodobenzylguanidine (MIBG) scintigraphy, and compared with 19 diabetic patients without the mutation. Duration of diabetes, therapy, control of blood glucose and diabetic complications, such as diabetic retinopathy and nephropathy, were not different between the 2 groups. Diabetic patients with the mutation had a significantly thicker interventricular septum (16.8±3.7 vs 11.0±1.6 mm, p 0.05). In conclusion, left ventricular hypertrophy with or without abnormal wall motion and severely reduced MIBG uptake may be characteristic in diabetic patients with a mutation in the mitochondrial tRNA Leu(UUR) gene. (author)

  1. Effects of anesthetic agents on cellular 123I-MIBG transport and in vivo 123I-MIBG biodistribution

    International Nuclear Information System (INIS)

    Ko, Bong-Ho; Paik, Jin-Young; Jung, Kyung-Ho; Bae, Jun-Sang; Lee, Eun Jung; Choe, Yearn Seong; Kim, Byung-Tae; Lee, Kyung-Han

    2008-01-01

    Small animal imaging with meta-iodobenzylguanidine (MIBG) allows characterization of animal models, optimization of tumor treatment strategies, and monitoring of gene expression. Anesthetic agents, however, can affect norepinephrine (NE) transport and systemic sympathetic activity. We thus elucidated the effects of anesthetic agents on MIBG transport and biodistribution. SK-N-SH neuroblastoma and PC-12 pheochromocytoma cells were measured for 123 I-MIBG uptake after treatment with ketamine (Ke), xylazine (Xy), Ke/Xy, or pentobarbital (Pb). NE transporters were assessed by Western blots. Normal ICR mice and PC-12 tumor-bearing mice were injected with 123 I-MIBG 10 min after anesthesia with Ke/Xy, Ke, Xy, or Pb. Plasma NE levels and MIBG biodistribution were assessed. Cellular 123 I-MIBG uptake was dose-dependently inhibited by Ke and Xy but not by Pb. Treatment for 2 h with 300 μM Ke, Xy, and Ke/Xy decreased uptake to 46.0 ± 1.6, 24.8 ± 1.5, and 18.3 ± 1.6% of controls. This effect was completely reversed by fresh media, and there was no change in NE transporter levels. In contrast, mice anesthetized with Ke/Xy showed no decrease of MIBG uptake in target organs. Instead, uptakes and organ-to-blood ratios were increased in the heart, lung, liver, and adrenals. Plasma NE was notably reduced in the animals with corresponding decreases in blood MIBG, which partly contributed to the increase in target organ uptake. In spite of their inhibitory effect at the transporter level, Ke/Xy anesthesia is a satisfactory method for MIBG imaging that allows favorable target tissue uptake and contrast by reducing circulating NE and MIBG. (orig.)

  2. Comparison of iodine-123 labelled 2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)tropane and 2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)-N-(3-fluoropropyl)nortropane for imaging of the dopamine transporter in the living human brain

    Energy Technology Data Exchange (ETDEWEB)

    Kuikka, J.T. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); Bergstroem, K.A. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); Ahonen, A. [Dept. of Clinical Chemistry, Oulu Univ. Central Hospital (Finland); Hiltunen, J. [MAP Medical Technologies Oy, Tikkakoski (Finland); Haukka, J. [MAP Medical Technologies Oy, Tikkakoski (Finland); Laensimies, E. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); Wang Shaoyin [Research Biochemicals International (RBI), Natick, MA (United States); Neumeyer, J.L. [Research Biochemicals International (RBI), Natick, MA (United States)

    1995-04-01

    Several cocaine congeners are of potential for imaging the dopamine transporter (DAT). Previous studies have shown that iodine-123 labelled 2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)tropane ([{sup 123}I]{beta}-CIT) is a promising radiotracer for imaging the serotonin (5-HT) and dopamine (DA) transporters in the living human brain with single-photon emission tomography (SPET). [{sup 123}I]{beta}-CIT was found to be not very practical for 1-day DAT imaging protocols since peak DAT uptake occurs later than 8 h. Here we report a pilot comparison of [{sup 123}I]{beta}-CIT and 2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)-N-(3-fluoropropyl)nortropane ([{sup 123}I]{beta}-CIT-FP), using SPET imaging in four healthy male subjects. Peak uptake of [{sup 123}I]{beta}-CIT-FP into the basal ganglia occurred earlier (3-4 h after injection of tracer) than that of [{sup 123}I]{beta}-CIT (>8 h). However, the specific DAT binding of [{sup 123}I]{beta}-CIT-FP in the basal ganglia was somewhat less (0.813{+-}0.047) than that of [{sup 123}I]{beta}-CIT (0.922{+-}0.004). Imaging quality is excellent with both tracers and they are potentially of value for brain imaging in various neuropsychiatric disorders. (orig.)

  3. Comparison of iodine-123 labelled 2β-carbomethoxy-3β-(4-iodophenyl)tropane and 2β-carbomethoxy-3β-(4-iodophenyl)-N-(3-fluoropropyl)nortropane for imaging of the dopamine transporter in the living human brain

    International Nuclear Information System (INIS)

    Kuikka, J.T.; Bergstroem, K.A.; Ahonen, A.; Hiltunen, J.; Haukka, J.; Laensimies, E.; Wang Shaoyin; Neumeyer, J.L.

    1995-01-01

    Several cocaine congeners are of potential for imaging the dopamine transporter (DAT). Previous studies have shown that iodine-123 labelled 2β-carbomethoxy-3β-(4-iodophenyl)tropane ([ 123 I]β-CIT) is a promising radiotracer for imaging the serotonin (5-HT) and dopamine (DA) transporters in the living human brain with single-photon emission tomography (SPET). [ 123 I]β-CIT was found to be not very practical for 1-day DAT imaging protocols since peak DAT uptake occurs later than 8 h. Here we report a pilot comparison of [ 123 I]β-CIT and 2β-carbomethoxy-3β-(4-iodophenyl)-N-(3-fluoropropyl)nortropane ([ 123 I]β-CIT-FP), using SPET imaging in four healthy male subjects. Peak uptake of [ 123 I]β-CIT-FP into the basal ganglia occurred earlier (3-4 h after injection of tracer) than that of [ 123 I]β-CIT (>8 h). However, the specific DAT binding of [ 123 I]β-CIT-FP in the basal ganglia was somewhat less (0.813±0.047) than that of [ 123 I]β-CIT (0.922±0.004). Imaging quality is excellent with both tracers and they are potentially of value for brain imaging in various neuropsychiatric disorders. (orig.)

  4. Adrenocortical Carcinoma: False Positive in an I-123 Metaiodobenzylguanidine Scan

    Energy Technology Data Exchange (ETDEWEB)

    Rey, Cristina Rodriguez; Candil, Aida Ortega; Galvan, Eliseo Vano; Martin, Maria Nieves Cabrera; Delgado, Jose Luis Carreras [Clinico San Carlos Hospital, Madrid (Spain)

    2016-06-15

    A 55-year-old man with a personal his history of left pheochromocytoma 2 years previously presented with an abdominal ultrasound showed a large left upper quadrant solid mass (calipers), with heterogeneous echogenicity and central cystic degeneration areas or necrosis. F-18 Fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT was performed as ACC was suspected. ACC is an uncommon malignant neoplasm of unknown cause; however, smoking and oral contraceptives may be risk factors. Patients usually present with advanced-stage disease and have poor prognosis, with a 2-year recurrence rate that ranges form 73 to 86 %. An MIBG scan was performed after injection of 185 MBq of I-123 MIBG intravenously. Single photon emission tomography (SPECT)/CT scan showed abnormal isotope accumulation in the tumor region. The patient underwent total resection of the tumor. The histology was of ACC, with areas of necrosis and cystic areas, so the result of the MIBG scan was a false positive. Authors divided false-positive MIBG studies into three categories. The first category is neuroendocrine lesions other than pheochromocytomas (tumors of the APUD series). the second category consists in adrenal lesions other than pheochromocytomas (adenomas, ACC) the reasons for this abnormal uptake are unclear. The third category consists of tracer uptake adjacent to the adrenal due to abnormalities in the route of excretion.

  5. Decreased myocardial 123I-MIBF uptake in Parkinson's disease

    International Nuclear Information System (INIS)

    Iwasa, K.; Takamori, M.; Nakajima, K.; Taki, J.; Yoshikawa, H.; Tada, A.

    1998-01-01

    We studied myocardial 123 I-metaiodobenzylguanidine (MIBG) accumulation in 12 patients with Parkinson's disease (PD). MIBG is an analog of norepinephrine (NE) and a tracer for sympathetic neuron integrity and function. MIBG uptake of the myocardium was significantly lower in PD than in controls. The heart to mediastinum ratio (H/M) was calculated by using the average count per pixel for the heart and mediastinum. In PD, H/M was lower than in controls (P<0.0001), while the washout ratio of the heart was higher (P<0.001). A decrease in myocardial accumulation of MIBG was observed in the early stage of PD. This suggests that the measurement of MIBF may help the diagnosis of early PD, and the causative factor underlying in PD may be operating the NE neuron as well as dopamine neuron. (au)

  6. Thallium-201 diethyldithiocarbamate: an alternative to iodine-123 N-isopropyl-p-iodoamphetamine

    NARCIS (Netherlands)

    de Bruine, J. F.; van Royen, E. A.; Vyth, A.; de Jong, J. M.; van der Schoot, J. B.

    1985-01-01

    The study of cerebral blood flow by single photon emission computed tomography (SPECT) requires lipophilic radiopharmaceuticals. The high cost and limited availability of N-isopropyl-p-[I-123]-iodoamphetamine ( [123I]IMP) led us to search for alternatives. Following our recent development of

  7. High-tension electrical injury to the heart as assessed by radionuclide imaging

    Energy Technology Data Exchange (ETDEWEB)

    Iino, Hitoshi; Chikamori, Taishiro; Hatano, Tsuguhisa [Tokyo Medical Coll. (Japan)] [and others

    2002-12-01

    The purpose of this study was to evaluate cardiac complications associated with electrical injury, 7 patients with high-tension electrical injury (6,600 V alternating current) underwent {sup 201}Tl and {sup 123}I-metaiodobenzylguanidine (MIBG) imaging in addition to conventional electrocardiographic and echocardiographic assessments. Electrocardiography showed transient atrial fibrillation, second degree atrioventricular block, ST-segment depression, and sinus bradycardia in each patient. Echocardiography showed mild hypokinesis of the anterior wall in only 2 patients, but {sup 201}Tl and {sup 123}I-MIBG myocardial scintigraphy showed an abnormal scan image in 6/7 and 5/6 patients, respectively. Decreased radionuclide accumulation was seen primarily in areas extending from the anterior wall to the septum. Decreased radionuclide accumulation was smaller in extent and milder in degree in {sup 123}I-MIBG than in {sup 201}Tl imaging. These results suggest that even in patients without definite evidence of severe cardiac complications in conventional examinations, radionuclide imaging detects significant damage due to high-tension electrical injury, in which sympathetic nerve dysfunction might be milder than myocardial cell damage. (author)

  8. Cardiac retention of PET neuronal imaging agent LMI1195 in different species: Impact of norepinephrine uptake-1 and -2 transporters

    International Nuclear Information System (INIS)

    Yu, Ming; Bozek, Jody; Kagan, Mikhail; Guaraldi, Mary; Silva, Paula; Azure, Michael; Onthank, David; Robinson, Simon P.

    2013-01-01

    Introduction: Released sympathetic neurotransmitter norepinephrine (NE) in the heart is cleared by neuronal uptake-1 and extraneuronal uptake-2 transporters. Cardiac uptake-1 and -2 expression varies among species, but the uptake-1 is the primary transporter in humans. LMI1195 is an NE analog labeled with 18 F for PET evaluation of cardiac neuronal function. This study investigated the impact of cardiac neuronal uptake-1 associated with different species on LMI1195 heart uptake. Methods: Cardiac uptake-1 was blocked by desipramine, a selective uptake-1 inhibitor, and sympathetic neuronal denervation was induced by 6-hydroxydopamine, a neurotoxin, in rats, rabbits and nonhuman primates (NHP). Tissue biodistribution and cardiac imaging of LMI1195 and 123 I-metaiodobenzylguanidine (MIBG) were performed. Results: In rats, uptake-1 blockade did not alter LMI1195 heart uptake compared to the control at 60-min post injection [1.41 ± 0.07 vs. 1.47 ± 0.23 % injected dose per gram tissue (%ID/g)]. In contrast, LMI1195 heart uptake was reduced by 80% in uptake-1 blocked rabbits. In sympathetically denervated rats, LMI1195 heart uptake was similar to the control (2.18 ± 0.40 vs. 2.58 ± 0.76 %ID/g). However, the uptake decreased by 79% in denervated rabbits. Similar results were found in MIBG heart uptake in rats and rabbits with uptake-1 blockade. Consistently, LMI1195 cardiac imaging showed comparable myocardial activity in uptake-1 blocked or sympathetically denervated rats to the control, but marked activity reduction in uptake-1 blocked or denervated rabbits and NHPs. Conclusions: LMI1195 is retained in the heart of rabbits and NHPs primarily via the neuronal uptake-1 with high selectivity and can be used for evaluation of cardiac sympathetic denervation. Similar to the human, the neuronal uptake-1 is the dominant transporter for cardiac retention of NE analogs in rabbits and NHPs, but not in rats

  9. The production of iodine-123 on the Harwell variable energy cyclotron

    International Nuclear Information System (INIS)

    Cuninghame, J.G.; Hill, J.I.S.; Nichols, A.L.; Taylor, N.K.

    1978-01-01

    123 I has often been called the isotope of choice for dynamic body function studies in nuclear medicine. There has therefore, been a keen interest in the possibility of regular supply of high purity 123 I produced by the Harwell Variable Energy Cyclotron (VEC) and Synchrocyclotron (SC). This report describes a three year research and development programme on the VEC which has resulted in a method for the safe and reliable large scale production of 123 I by irradiation of di-iodomethane with 58 MeV protons. The quality of the product, and the medical trials which have been carried out with it, are also discussed. The processing and handling of the hundreds of millicuries produced during a run presents serious handling problems. These have been solved and the methods and equipment developed are described. (author)

  10. Preparation of directly iodinated steroid hormones and related directly halogenated compounds

    International Nuclear Information System (INIS)

    Sahadevan, V.

    1981-01-01

    The preparation of directly iodinated radioactive steroid hormones is described for use in radioimmunoassays or radiolocalization and treatment of human breast tumours. The radioactive iodinated steroid hormone is prepared by reacting a parent steroid hormone with an alkali metal iodide containing radioactive 123 I, 125 I, 130 I or 131 I in the presence of hydrogen peroxide or chloramine-T. The parent steroid hormones include the adrenal corticosteroids, the estrogens, the progestogens, the progestins and the diuretic and antidiuretic agents. The radioactive iodinated steroid hormone is prepared by iodinating the parent steroid hormone directly on the cyclopentanophenanthrene nucleus. The radioactive iodinated steroid hormones have the same antigenicity and receptor site specificity as the parent steroid hormone. The invention is illustrated by 1) the method of iodination of estradiol-17β, 2) results for the percentage labelling of several steroids and steroid hormones, 3) results for the radioimmunoassay of 125 I-estradiol and 4) results for the binding of directly iodinated estradiol-17β in an estrogen receptor assay of human breast cancer. (U.K.)

  11. Evaluation of cardiac sympathetic nerve activity and aldosterone suppression in patients with acute decompensated heart failure on treatment containing intravenous atrial natriuretic peptide

    Energy Technology Data Exchange (ETDEWEB)

    Kasama, Shu [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Cardiovascular Hospital of Central Japan (Kitakanto Cardiovascular Hospital), Department of Cardiovascular Medicine, Gunma (Japan); Toyama, Takuji; Kurabayashi, Masahiko [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Iwasaki, Toshiya; Sumino, Hiroyuki; Kumakura, Hisao; Minami, Kazutomo; Ichikawa, Shuichi [Cardiovascular Hospital of Central Japan (Kitakanto Cardiovascular Hospital), Department of Cardiovascular Medicine, Gunma (Japan); Matsumoto, Naoya [Nihon University School of Medicine, Department of Cardiology, Tokyo (Japan); Nakata, Tomoaki [Sapporo Medical University School of Medicine, Second (Cardiology) Department of Internal Medicine, Sapporo, Hokkaido (Japan)

    2014-09-15

    Aldosterone prevents the uptake of norepinephrine in the myocardium. Atrial natriuretic peptide (ANP), a circulating hormone of cardiac origin, inhibits aldosterone synthase gene expression in cultured cardiocytes. We evaluated the effects of intravenous ANP on cardiac sympathetic nerve activity (CSNA) and aldosterone suppression in patients with acute decompensated heart failure (ADHF). We studied 182 patients with moderate nonischemic ADHF requiring hospitalization and treated with standard therapy containing intravenous ANP and 10 age-matched normal control subjects. ANP was continuously infused for >96 h. In all subjects, delayed total defect score (TDS), heart to mediastinum ratio, and washout rate were determined by {sup 123}I-metaiodobenzylguanidine (MIBG) scintigraphy. Left ventricular (LV) end-diastolic volume, end-systolic volume, and ejection fraction were determined by echocardiography. All patients with acute heart failure (AHF) were examined once within 3 days and then 4 weeks after admission, while the control subjects were examined only once (when their hemodynamics were normal). Moreover, for 62 AHF patients, plasma aldosterone concentrations were measured at admission and 1 h before stopping ANP infusion. {sup 123}I-MIBG scintigraphic and echocardiographic parameters in normal subjects were more favorable than those in patients with AHF (all p < 0.001). After treatment, all these parameters improved significantly in AHF patients (all p < 0.001). We also found significant correlation between percent changes of TDS and aldosterone concentrations (r = 0.539, p < 0.001) in 62 AHF patients. The CSNA and LV performance were all improved in AHF patients. Furthermore, norepinephrine uptake of myocardium may be ameliorated by suppressing aldosterone production after standard treatment containing intravenous ANP. (orig.)

  12. Synthesis and evaluation of three iodinated haloperidol derivatives as potential dopamine receptor imaging agents

    International Nuclear Information System (INIS)

    Hunter, D.H.; Strickland, L.A.; Zabel, P.L.

    1990-01-01

    Haloperidol, a neuroleptic which shows D-2 receptor affinity and selectivity, has been labelled primarily with positron emitting isotopes. The authors have synthesized three iodinated analogues of Haloperidol to investigate the possibility of an iodine-123 labelled agent for SPECT imaging. These compounds were obtained from the substitution of halogenated butyrophenones by halogenated arylpiperidols. In vitro and in vivo experiments will be discussed

  13. A novel route to radioiodinated [{sup 123}I]-N-succinimidyl-3-iodobenzoate, a reagent for radioiodination of bioactive peptides

    Energy Technology Data Exchange (ETDEWEB)

    Al-Jammaz, I.; Al-Otaibi, B.; Amartey, J.K. E-mail: amarty@kfshrc.edu.sa

    2002-11-01

    Radiolabeled peptides continue to emerge as potential radiopharmaceuticals for targeting several diseases such as cancer, infection and inflammation and even tissue and organ rejection. The classical method for labeling these molecules has been the electrophilic route. Evidence suggests that most molecules labeled via this route perturb their biological activity. Moreover, this method is not applicable to peptides lacking a tyrosine moiety in their structure. Hence, there is the need to develop alternate methods such as the prosthetic approach. We have optimized a solid-state radioiodination by exchange to produce [{sup 123}I]-metaiodobenzylguanidine ([{sup 123}I]-mIBG). The mIBG served as a precursor to obtain an activated N-succinimidyl ester for efficient coupling to amine functions in peptides, preferably the lysine group(s). The method was used to label a model chemotactic peptide and evaluated in vivo.

  14. Structural changes in Parkinson's disease: voxel-based morphometry and diffusion tensor imaging analyses based on 123I-MIBG uptake.

    Science.gov (United States)

    Kikuchi, Kazufumi; Hiwatashi, Akio; Togao, Osamu; Yamashita, Koji; Somehara, Ryo; Kamei, Ryotaro; Baba, Shingo; Yamaguchi, Hiroo; Kira, Jun-Ichi; Honda, Hiroshi

    2017-12-01

    Patients with Parkinson's disease (PD) may exhibit symptoms of sympathetic dysfunction that can be measured using 123 I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy. We investigated the relationship between microstructural brain changes and 123 I-MIBG uptake in patients with PD using voxel-based morphometry (VBM) and diffusion tensor imaging (DTI) analyses. This retrospective study included 24 patients with PD who underwent 3 T magnetic resonance imaging and 123 I-MIBG scintigraphy. They were divided into two groups: 12 MIBG-positive and 12 MIBG-negative cases (10 men and 14 women; age range: 60-81 years, corrected for gender and age). The heart/mediastinum count (H/M) ratio was calculated on anterior planar 123 I-MIBG images obtained 4 h post-injection. VBM and DTI were performed to detect structural differences between these two groups. Patients with low H/M ratio had significantly reduced brain volume at the right inferior frontal gyrus (uncorrected p  90). Patients with low H/M ratios also exhibited significantly lower fractional anisotropy than those with high H/M ratios (p based morphometry can detect grey matter changes in Parkinson's disease. • Diffusion tensor imaging can detect white matter changes in Parkinson's disease.

  15. Radiation dosimetry of iodine-123 HEAT, an alpha-1 receptor imaging agent

    International Nuclear Information System (INIS)

    Thomas, K.D.; Greer, D.M.; Couch, M.W.; Williams, C.M.

    1987-01-01

    Biologic distribution data in the rat were obtained for the alpha-1 adrenoceptor imaging agent (+/-) 2-[beta-(iodo-4-hydroxyphenyl)ethylaminomethyl]tetralone (HEAT) labeled with [ 123 I]. The major excretory routes were through the liver (67%) and the kidney (33%). Internal radiation absorbed dose estimates to nine source organs, total body, the GI tract, gonads, and red bone marrow were calculated for the human using the physical decay data for [ 123 I]. The critical organ was found to be the lower large intestine, receiving 1.1 rad per mCi of [ 123 I]HEAT administered. The total-body dose was found to be 58 mrad per mCi

  16. New syntheses of No-carrier-added 123I-labeled agents via organoborane chemistry

    International Nuclear Information System (INIS)

    Kabalka, G.W.

    1985-01-01

    No-carrier-added 123 I-labeled agents are readily prepared via the reaction of organoboranes with sodium iodide- 123 I in the presence of mild oxidizing agents. The reactions are rapid and regiospecific, and they produce excellent yields of the labeled products. The organoboranes are readily prepared from alkenes and alkynes via the hydroboration reaction. A wide variety of functional groups are tolerated by the hydroboration-iodination sequence. The sequence has been utilized to prepare 123 I-labeled steroids and fatty acids, as well as a number of labeled esters, and aromatic derivatives

  17. Effects of anesthetic agents on cellular {sup 123}I-MIBG transport and in vivo {sup 123}I-MIBG biodistribution

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Bong-Ho; Paik, Jin-Young; Jung, Kyung-Ho; Bae, Jun-Sang; Lee, Eun Jung; Choe, Yearn Seong; Kim, Byung-Tae; Lee, Kyung-Han [Sungkyunkwan University School of Medicine, Department of Nuclear Medicine, Samsung Medical Center, Seoul (Korea)

    2008-03-15

    Small animal imaging with meta-iodobenzylguanidine (MIBG) allows characterization of animal models, optimization of tumor treatment strategies, and monitoring of gene expression. Anesthetic agents, however, can affect norepinephrine (NE) transport and systemic sympathetic activity. We thus elucidated the effects of anesthetic agents on MIBG transport and biodistribution. SK-N-SH neuroblastoma and PC-12 pheochromocytoma cells were measured for {sup 123}I-MIBG uptake after treatment with ketamine (Ke), xylazine (Xy), Ke/Xy, or pentobarbital (Pb). NE transporters were assessed by Western blots. Normal ICR mice and PC-12 tumor-bearing mice were injected with {sup 123}I-MIBG 10 min after anesthesia with Ke/Xy, Ke, Xy, or Pb. Plasma NE levels and MIBG biodistribution were assessed. Cellular {sup 123}I-MIBG uptake was dose-dependently inhibited by Ke and Xy but not by Pb. Treatment for 2 h with 300 {mu}M Ke, Xy, and Ke/Xy decreased uptake to 46.0 {+-} 1.6, 24.8 {+-} 1.5, and 18.3 {+-} 1.6% of controls. This effect was completely reversed by fresh media, and there was no change in NE transporter levels. In contrast, mice anesthetized with Ke/Xy showed no decrease of MIBG uptake in target organs. Instead, uptakes and organ-to-blood ratios were increased in the heart, lung, liver, and adrenals. Plasma NE was notably reduced in the animals with corresponding decreases in blood MIBG, which partly contributed to the increase in target organ uptake. In spite of their inhibitory effect at the transporter level, Ke/Xy anesthesia is a satisfactory method for MIBG imaging that allows favorable target tissue uptake and contrast by reducing circulating NE and MIBG. (orig.)

  18. Trends in Cardiac Pacemaker Batteries

    Directory of Open Access Journals (Sweden)

    Venkateswara Sarma Mallela

    2004-10-01

    Full Text Available Batteries used in Implantable cardiac pacemakers-present unique challenges to their developers and manufacturers in terms of high levels of safety and reliability. In addition, the batteries must have longevity to avoid frequent replacements. Technological advances in leads/electrodes have reduced energy requirements by two orders of magnitude. Micro-electronics advances sharply reduce internal current drain concurrently decreasing size and increasing functionality, reliability, and longevity. It is reported that about 600,000 pacemakers are implanted each year worldwide and the total number of people with various types of implanted pacemaker has already crossed 3 million. A cardiac pacemaker uses half of its battery power for cardiac stimulation and the other half for housekeeping tasks such as monitoring and data logging. The first implanted cardiac pacemaker used nickel-cadmium rechargeable battery, later on zinc-mercury battery was developed and used which lasted for over 2 years. Lithium iodine battery invented and used by Wilson Greatbatch and his team in 1972 made the real impact to implantable cardiac pacemakers. This battery lasts for about 10 years and even today is the power source for many manufacturers of cardiac pacemakers. This paper briefly reviews various developments of battery technologies since the inception of cardiac pacemaker and presents the alternative to lithium iodine battery for the near future.

  19. Meta-iodobenzylguanidine adrenal medulla localization

    International Nuclear Information System (INIS)

    Guilloteau, D.; Baulieu, J.L.; Chambon, C.; Valat, C.; Baulieu, F.; Itti, R.; Pourcelot, L.; Besnard, J.C.; Huguet, F.; Narcisse, G.; Viel, C.

    1984-01-01

    In order to investigate the mechanism of uptake of meta-iodobenzylguanidine (mIBG) by the adrenal glands, autoradiographic and pharmacologic studies were performed in mice and dogs receiving radioiodinated mIBG. In mice, on macroautoradiography of whole body section 48 h after 125 I-mIBG, most of the radioactivity was focused in the adrenal glands. On microautoradiography, silver grains were exclusively located in the adrenal medulla. Time counting after phenoxybenzamine, cocaine, and desipramine treatment resulted in 45%, 35%, and 0% inhibition of mIBG uptake, respectively. Tissue counting and scintigraphic studies demonstrated a more than 50% mIBG release from the adrenal glands. These data indicate the high affinity of mIBG for adrenal medulla and suggest that the mIBG and catecholamine uptake mechanisms are onlt partially the same. (orig.)

  20. Iodine concentration calculated by dual-energy computed tomography (DECT) as a functional parameter to evaluate thyroid metabolism in patients with hyperthyroidism.

    Science.gov (United States)

    Binh, Duong Duc; Nakajima, Takahito; Otake, Hidenori; Higuchi, Tetsuya; Tsushima, Yoshito

    2017-07-19

    Thyroid function in patients with Grave's disease is usually evaluated by thyroid scintigraphy with radioactive iodine. Recently, dual-energy computed tomography (DECT) with two different energy X-rays can calculate iodine concentrations and can be applied for iodine measurements in thyroid glands. This study aimed to assess the potential use of DECT for the functional assessment of the thyroid gland. Thirteen patients with Grave's disease treated at our hospital from May to September 2015 were included in this retrospective study. Before treatments, all subjects had undergone both iodine scintigraphy [three and 24 h after oral administration of 123 I (20 μCi)] and non-enhanced DECT. The region of interests (ROIs) were placed in both lobes of the thyroid glands, and CT values (HU: Hounsfield unit) and iodine concentrations (mg/mL) calculated from DECT images were measured. The correlation between CT values and iodine concentrations from DECT in the thyroid gland was evaluated and then the iodine concentrations were compared with radioactive iodine uptake ratios by thyroid scintigraphy. Mean (±SD) 123 I uptake increased from 46.3 (±22.2) % (range, 11.1-80.1) at 3 h, to 66.5 (±15.2) % (range, 40.0-86.1) at 24 h (p hyperthyroid patients.

  1. Radioisotope exploration of transplanted kidneys using 123I-hippuran

    International Nuclear Information System (INIS)

    Champailler, A.; Juge, J.; Herrmann, T.; Berthoux, F.; Healy, J.C.

    1983-01-01

    Hippuran labelled with iodine 123 is now used for short- and long-terme monitoring of renal transplants. Sixty-one explorations were performed in 24 patients, using this new radiopharmaceutical agent. Repeated explorations, facilitated by the lower doses of radiations as compared with 131 I-hippuran, are particularly useful to diagnose thrombosis of the renal artery, early acute tubular lesions, acute and chronic rejection and impaired evacuation of the kidney. 123 I-hippuran is the first-choice method of exploration of transplanted kidneys and can be followed, if required, by explorations more aggressive for the patient and the kidney [fr

  2. Evaluation of thyroid nodules by 123I thyroid scintigraphy and computed tomography

    International Nuclear Information System (INIS)

    Kurihara, Yoshiko; Imanishi, Yoshimasa; Ehara, Norishige

    1991-01-01

    We have already reported that computed tomography (CT) could be used to quantify iodine concentration in the thyroid. Correlation between CT value and iodine concentration in thyroid tissues was represented by the following formula (n=31, r=0.96): iodine concentration=(CT value-65)/104 (mg/g). In this study, we evaluated thyroid nodules by 123 I thyroid scintigraphy and histograms of CT values in the nodules. Radioiodine accumulation and the histograms on CT of the thyroid nodules were correlated with the histopathology of 35 thyroid nodules (22 benign nodules, 13 malignant nodules) of 27 patients. Results showed no definite correlation between radioiodine accumulation in the thyroid nodule and the pattern on CT reflecting iodine concentration in the nodule. Some nodules with little radioiodine accumulation had considerable iodine concentration. Benign thyroid nodules tended to have lower iodine concentration than malignant nodules. Fifteen (94%) of 16 nodules showing only minimal iodine concentration were benign. We conclude that the function and/or differentiation of tumor cells in the thyroid nodule must be evaluated not only radioiodine accumulation in the nodule but also by iodine concentration in the nodule and that thyroid nodules with only minimal iodine concentration are most likely benign. (author)

  3. Myocardial rest iodine-123-β-methyl-iodophenyl-pentadecanoic acid scintigraphy compared with dipyridamole stress thallium-201 scintigraphy in unstable angina

    International Nuclear Information System (INIS)

    Misumi, Ikuo; Kimura, Yoshihiro; Hokamura, Youichi; Yamabe, Hiroshige; Ueno, Kazuhiro

    1998-01-01

    Twelve patients with stable angina and 12 patients with unstable angina underwent rest iodine-123-β-methyl-iodophenyl-pentadecanoic acid (BMIPP), dipyridamole stress thallium scintigraphy and delayed thallium scintigraphy. In stable angina, sensitivity for detecting ischemic segments was higher in dipyridamole thallium (74%) than rest BMIPP (48%) images (p<0.05), but there was no significant difference between the 2 images in unstable angina. In unstable angina, the incidence of segments with higher defect scores on BMIPP images than on delayed thallium images and the opposite pattern was 27 and 5 (p<0.01). In stable angina, there was no difference. The mean defect score on BMIPP (6.3±5.6) was higher than that on delayed thallium scintigraphy (2.9±2.7) and it was almost the same as on the initial dipyridamole stress test (6.5±5.2). In conclusion, BMIPP scintigraphy is safer and may be as useful in detecting myocardial ischemia in patients with unstable angina as thallium scintigraphy. (author)

  4. Brain {sup 18}F-FDG, {sup 18}F-florbtaben PET/CT, {sup 123}I-FP-CIT SPECT and cardiac {sup 123}I-MBG imaging for diagnosis of a 'cerebral type' of Lewy Body disease

    Energy Technology Data Exchange (ETDEWEB)

    Gucht, Axel Van Der; Bélissant, Ophélie; Rabu, Corenti; Cottereau, Anne-Ségolène; Evangelista, Eva; Chalaye, Julia; Bonnot-Lours, Sophie; Fénelon, Gilles; Itti, Emmanuel [Dept. of Nuclear Medicine, AP-HP, Henri-Mondor Teaching Hospital, Crteil (France); De Langavant, Laurent Cleret [Cognitive Neurology Unit, H. Mondor Hospital, Creteil (France)

    2016-09-15

    A 67-year-old man was referred for fluctuating neuropsychiatric symptoms, featuring depression, delirious episodes, recurrent visual hallucinations and catatonic syndrome associated with cognitive decline. No parkinsonism was found clinically even under neuroleptic treatment. {sup 18}F-FDG PET/CT showed hypometabolism in the posterior associative cortex including the occipital cortex, suggesting Lewy body dementia, but {sup 123}I-FP-CIT SPECT was normal and cardiac {sup 123}I-MIBG imaging showed no signs of sympathetic denervation. Alzheimer's disease was excluded by a normal {sup 18}F-florbetaben PET/CT. This report suggests a rare case of α-synucleinopathy without brainstem involvement, referred to as 'cerebral type' of Lewy body disease.

  5. Iodine-123 uptake in vertebral haemangiomas in a patient with papillary thyroid carcinoma

    International Nuclear Information System (INIS)

    Sameer Khan, S.; Dunn, J.; All-Nahhas, A.; Strickland, N.

    2008-01-01

    We present a case of a 58-year-old woman with papillary carcinoma of the thyroid and elevated thyroglobulin. Whole body 123 I scan with SPECT images demonstrated focal uptake in the thoracic spine, reported as bone metastases. Subsequent 18 F DG PET and 99m Tc HDP bone were normal. MRI and CT scans confirmed the presence of vertebral haemangiomas corresponding to the uptake seen on the 123 I scan. False-positive uptake of 123 I in benign vertebral haemangiomas should be considered in the differential diagnosis of focal vertebral uptake. (authors)

  6. Chromatographic separation of Iodine species for environmental studies

    Energy Technology Data Exchange (ETDEWEB)

    Machado, E.C. [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Geoquimica]. E-mail: geoedin@vm.uff.br; Bellido, A.V.B. [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Fisico-Quimica]. E-mail: alf@risc2.rmn.uff.br; Bellido, L.F. [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)]. E-mail: lbellido@cnen.gov.br

    1999-07-01

    In this work a experimental method was developed to separate iodine species from environmental samples by using adsorption chromatography. The radionuclide {sup 123} I which has a half-life of 13 h and a convenient gamma ray of 159 keV was used to investigate a fast and efficient procedure for the separation of iodide and iodate ions in seawater from mangrove samples. The radio-iodine tracer technique is very useful, particularly in kinetic studies because it is easy to detect without any interference of concentration due to the small amount of tracer that is spiked. It is also possible to add two tracers (I-123 and I-131) in different oxidation states. Three chromatographic methods were studied: paper, thin layer and adsorption chromatography with silica and alumina. It was found that paper chromatography is very useful for checking the valence adjustment of the radioiodine species. Initially, several coefficient distributions of iodine species by adsorption in silica and alumina from NaOH, NaHCO{sub 3} and NaNO{sub 3} solutions (in the range 05. - 0.0001 m) were determined. The best separation so far was achieved by loading the sample (after adjusting the concentration to 0.1 NNaNO{sub 3}) into a chromatographic column with Al{sub 2} O{sub 3}. The iodide passes through the column and after washing the column, the iodate was removed by eluting with 1.0 M NaHCO{sub 3} solution. (author)

  7. Chromatographic separation of Iodine species for environmental studies

    International Nuclear Information System (INIS)

    Machado, E.C.

    1999-01-01

    In this work a experimental method was developed to separate iodine species from environmental samples by using adsorption chromatography. The radionuclide 123 I which has a half-life of 13 h and a convenient gamma ray of 159 keV was used to investigate a fast and efficient procedure for the separation of iodide and iodate ions in seawater from mangrove samples. The radio-iodine tracer technique is very useful, particularly in kinetic studies because it is easy to detect without any interference of concentration due to the small amount of tracer that is spiked. It is also possible to add two tracers (I-123 and I-131) in different oxidation states. Three chromatographic methods were studied: paper, thin layer and adsorption chromatography with silica and alumina. It was found that paper chromatography is very useful for checking the valence adjustment of the radioiodine species. Initially, several coefficient distributions of iodine species by adsorption in silica and alumina from NaOH, NaHCO 3 and NaNO 3 solutions (in the range 05. - 0.0001 m) were determined. The best separation so far was achieved by loading the sample (after adjusting the concentration to 0.1 NNaNO 3 ) into a chromatographic column with Al 2 O 3 . The iodide passes through the column and after washing the column, the iodate was removed by eluting with 1.0 M NaHCO 3 solution. (author)

  8. Iodine Intake in Somalia Is Excessive and Associated with the Source of Household Drinking Water123

    Science.gov (United States)

    Kassim, Ismail A. R.; Moloney, Grainne; Busili, Ahono; Nur, Abukar Yusuf; Paron, Paolo; Jooste, Pieter; Gadain, Hussein; Seal, Andrew J.

    2014-01-01

    Few data on iodine status in Somalia are available, but it is assumed that deficiency is a public health problem due to the limited access to iodized salt. We aimed to describe the iodine status of the population of Somalia and to investigate possible determinants of iodine status. A national 2-stage, stratified household cluster survey was conducted in 2009 in the Northwest, Northeast, and South Central Zones of Somalia. Urinary iodine concentration (UIC) was determined in samples from women (aged 15–45 y) and children (aged 6–11 y), and examination for visible goiter was performed in the Northwest and South Central strata. A 24-h household food-frequency questionnaire was conducted, and salt samples were tested for iodization. The median UICs for nonpregnant women and children were 329 and 416 μg/L, respectively, indicating excessive iodine intake (>300 μg/L). The prevalence of visible goiter was Somalia is among the highest in the world and excessive according to WHO criteria. Further work is required to investigate the geochemistry and safety of groundwater sources in Somalia and the impact on human nutrition and health. PMID:24500936

  9. Comparative value of brain perfusion SPECT and [{sup 123}I]MIBG myocardial scintigraphy in distinguishing between dementia with Lewy bodies and Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Hanyu, Haruo; Shimizu, Soichiro; Hirao, Kentaro; Kanetaka, Hidekazu; Iwamoto, Toshihiko [Tokyo Medical University, Department of Geriatric Medicine, Tokyo (Japan); Chikamori, Taishiro; Usui, Yasuhiro; Yamashina, Akira [Tokyo Medical University, 2. Department of Internal Medicine, Tokyo (Japan); Koizumi, Kiyoshi; Abe, Kimihiko [Tokyo Medical University, Department of Radiology, Tokyo (Japan)

    2006-03-15

    Both decreased occipital perfusion on brain single-photon emission computed tomography (SPECT) and reduction in cardiac {sup 123}I-metaiodobenzylguanidine (MIBG) uptake are characteristic features of dementia with Lewy bodies (DLB), and potentially support the clinical diagnosis of DLB. The aim of this study was to compare the diagnostic value of these two methods for differentiation of DLB from Alzheimer's disease (AD). The study population comprised 19 patients with probable DLB and 39 patients with probable AD who underwent both SPECT with N-isopropyl-p-[{sup 123}I]iodoamphetamine and MIBG myocardial scintigraphy. Objective and quantitative measurement of perfusion in the medial occipital lobe, including the cuneus and lingual gyrus, was performed by the use of three-dimensional stereotactic surface projections. Medial occipital perfusion was significantly decreased in the DLB group compared with the AD group. The mean heart/mediastinum ratios of MIBG uptake were significantly lower in the DLB group than in the AD group. Although SPECT failed to demonstrate significant hypoperfusion in the medial occipital lobe in five patients with DLB, marked reduction of MIBG uptake was found in all patients with DLB. Receiver operating characteristic analysis revealed that MIBG myocardial scintigraphy enabled more accurate discrimination between DLB and AD than was possible with perfusion SPECT. MIBG myocardial scintigraphy may improve the sensitivity in the detection of DLB. In particular, this method may provide a powerful differential diagnostic tool when it is difficult to distinguish cases of DLB from AD using brain perfusion SPECT. (orig.)

  10. [sup 123]I-iodobenzoylglucosamines: glucose analogues for heart imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lutz, T [British Columbia Univ., Vancouver, BC (Canada). Dept. of Pharmaceutical Sciences; Dougan, H [TRIUMF, Vancouver, BC (Canada); Rihela, T; Vo, C V [Vancouver General Hospital (Canada). Div. of Nuclear Medicine; Lyster, D M [British Columbia Univ., Vancouver, BC (Canada). Dept. of Pharmaceutical Sciences Vancouver General Hospital (Canada). Div. of Nuclear Medicine

    1993-01-01

    The ortho-, meta- and para-[[sup 123]I]-2-deoxy-2-N-(iodobenzoyl)-D-glucosamine (BGA) derivatives were investigated to determine the effect of iodine position and lipophilicity on tissue distribution. There was no correlation between tissue uptake and lipophilicity. Maximum uptake was observed for o-BGA displaying a heart:blood ratio of 36.0 at 18 hours post injection. Yeast hexokinase phosphorylation studies in vitro and an in vivo insulin experiment were carried out on o-BGA. No phosphorylation was detected, but the insulin study indicated that o-BGA uses the glucose transporter. o-BGA showed maximum tissue uptake in mice at an optimal specific activity of 0.004mg/[mu]Ci. Mouse biodistribution studies of o-[[sup 123]I]-iodobenzamide(o-[sup 123]IBA) indicated that the glucose moiety of o-BGA may be involved in the heart accumulation process in mice. Heart tissue extraction studies showed unmetabolized o-[[sup 123]I]BGA was the predominant species. A rabbit image of o-[[sup 123]I]BGA, recorded at 14 hours post injection, showed significant heart uptake. (author).

  11. Uptake of iodine-123-α-methyl tyrosine by gliomas and non-neoplastic brain lesions

    International Nuclear Information System (INIS)

    Kuwert, T.; Morgenroth, C.; Woesler, B.; Matheja, P.; Palkovic, S.; Vollet, B.; Samnick, S.; Maasjosthusmann, U.; Lerch, H.; Gildehaus, F.J.; Wassmann, H.; Schober, O.

    1996-01-01

    Using single-photon emission tomography (SPET), the radiopharmaceutical L-3-iodine-123-α-methyl tyrosine (IMT) has been applied to the imaging of amino acid transport into brain tumours. It was the aim of this study to investigate whether IMT SPET is capable of differentiating between high-grade gliomas, low-grade gliomas and non-neoplastic brain lesions. To this end, IMT uptake was determined in 53 patients using the triple-headed SPET camera MULTISPECT 3. Twenty-eight of these subjects suffered from high-grade gliomas (WHO grade III or IV), 12 from low-grade gliomas (WHO grade II), and 13 from non-neoplastic brain lesions, including lesions after effective therapy of a glioma (five cases), infarctions (four cases), inflammatory lesions (three cases), infarctions (four cases), inflammatory lesions (three cases) and traumatic haematoma (one case). IMT uptake was significantly higher in high-grade gliomas than in low-grade gliomas and non-neoplastic lesions. IMT uptake by low-grade gliomas was not significantly different from that by non-neoplastic lesions. Diagnostic sensitivity and specificity were 71% and 83% for differentiating high-grade from low-grade gliomas, 82% and 100% for distinguishing high-grade gliomas from non-neoplastic lesions, and 50% and 100% for discriminating low-grade gliomas from non-neoplastic lesions. Analogously to positron emission tomography with radioactively labelled amino acids and fluorine-18 deoxyglucose, IMT SPET may aid in differentiating higc-grade gliomas from histologically benign brain tumours and non-neoplastic brain lesions; it is of only limited value in differentiating between non-neoplastic lesions and histologically benign brain tumours. (orig.)

  12. Brain SPECT with 123I-Lisurid in patients with Parkinson's disease and in controls

    International Nuclear Information System (INIS)

    Hierholzer, J.; Cordes, M.; Schelosky, L.; Richter, W.; Schrag, A.; Poewe, W.; Schulze, P.E.; Semmler, W.; Eichstaedt, H.; Felix, R.

    1995-01-01

    The goal was to visualize cerebral dopamine-D 2 receptors in 6 patients with Parkinson's disease and in 3 healthy controls using iodine-123-Lisuride-SPECT. In addition, we performed receptor-replacement studies using 123 I-Lisuride and cold Lisuride as competitive ligands. The highest uptake of 123 I-Lisuride was observed in the striatum, a region with known high dopamine receptor density. In two patients premedication with cold Lisuride displaced 123 I-Lisuride from the dopamine receptor. 123 I-Lisuride is valuable as a radiotracer in cerebral dopamine-D 2 receptor scintigraphy. Whether or not it is possible to determine dynamic changes of dopamine receptor density or function by receptor replacement studies needs further evaluation in larger patient populations. (orig.) [de

  13. Iodine-123-labeled pH shift brain-imaging agents

    International Nuclear Information System (INIS)

    Blau, M.; Kung, H.F.

    1985-01-01

    HIPDM is an 123 I-labeled agent with a distribution in brain reflecting regional perfusion. This compound is neutral and lipid soluble at blood pH and freely crosses the blood-brain barrier. At the lower pH in brain, it picks up a hydrogen ion and becomes positively charged. In this form the molecule is not lipid soluble and it is trapped in brain

  14. Neuronal imaging using SPECT

    International Nuclear Information System (INIS)

    Yamashina, Shohei; Yamazaki, Jun-ichi

    2007-01-01

    123 I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy is one of only a few methods available for objective evaluation of cardiac sympathetic function at the clinical level. Disorders of cardiac sympathetic function play an important role in various heart diseases, and MIBG provides an abundance of useful information for the evaluation of severity, prognosis and therapeutic effects; this is particularly useful in cases of heart failure, ischaemic heart disease and arrhythmic disease. On the other hand, the quantitative indices for MIBG differ between institutions, and evidence has not been sufficiently well established for MIBG scintigraphy when compared with myocardial perfusion imaging in ischaemic heart diseases. In consideration of these difficulties, this review provides fundamental information regarding MIBG, its usefulness for various diseases and future difficulties. (orig.)

  15. Neuronal imaging using SPECT

    International Nuclear Information System (INIS)

    Yamashina, Shohei; Yamazaki, Jun-ichi

    2007-01-01

    123 I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy is one of only a few methods available for objective evaluation of cardiac sympathetic function at a clinical level. Disorders in cardiac sympathetic function play an important role in various heart diseases, and MIBG provides an abundance of useful information for evaluation of disease severity, prognosis, and therapeutic effects; this information is of particular value in patients with heart failure, ischemic heart diseases, or arrhythmic disorders. On the other hand, the quantitative indices for MIBG differ between institutions, and evidence has not been sufficiently well established for MIBG, compared with myocardial perfusion imaging, in ischemic heart diseases. In view of these difficulties, this review provides fundamental information regarding MIBG, its usefulness for various diseases and future difficulties. (orig.)

  16. Diagnostic cutoff points for {sup 123}I-MIBG myocardial scintigraphy in a Caucasian population with Parkinson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Muxi, Africa; Paredes, Pilar [Hospital Clinic, Universitat de Barcelona, Nuclear Medicine Department, Barcelona (Spain); Institut d' Investigacions Biomediques August Pi i Sunyer (IDIBAPS), Barcelona (Spain); RECAVA, Instituto de Salud Carlos III, Barcelona (Spain); Agencia de Gestio d' Ajuts Universitaris i de Recerca (AGAUR 2009 SGR 1049), Barcelona (Spain); Navales, Ignacio; Sola, Oriol; Domenech, Beatriz [Hospital Clinic, Universitat de Barcelona, Nuclear Medicine Department, Barcelona (Spain); Valldeoriola, Francesc; Gaig, Carles; Cerda, Andres de la; Tolosa, Eduardo [Hospital Clinic, Universitat de Barcelona, Movement Disorders Unit, Neurology Department, Barcelona (Spain); Institut d' Investigacions Biomediques August Pi i Sunyer (IDIBAPS), Barcelona (Spain); Lomena, Francisco [Hospital Clinic, Universitat de Barcelona, Nuclear Medicine Department, Barcelona (Spain); Institut d' Investigacions Biomediques August Pi i Sunyer (IDIBAPS), Barcelona (Spain); Pons, Francesca [Hospital Clinic, Universitat de Barcelona, Nuclear Medicine Department, Barcelona (Spain); Institut d' Investigacions Biomediques August Pi i Sunyer (IDIBAPS), Barcelona (Spain); Agencia de Gestio d' Ajuts Universitaris i de Recerca (AGAUR 2009 SGR 1049), Barcelona (Spain)

    2011-06-15

    Molecular imaging with {sup 123}I-metaiodobenzylguanidine (MIBG) has been used in Parkinson's disease (PD), but there is no consensual index to discriminate between normal and PD patients in the Caucasian population. The purpose of this study was to determine diagnostic cutoff points in the quantification of MIBG cardiac uptake in our population of PD patients. We have also calculated the reproducibility over a range of interpretation expertise. The study included 14 PD patients and 14 normal age- and sex-matched controls. Heart to mediastinum ratios (H/M) were calculated at 15 min (H/M15m) and 4 h (H/M4h) post-injection by three observers with different interpretation expertise, one of whom drew the regions of interest at three different times. The intraobserver and interobserver reliability was calculated (interclass correlation coefficient and coefficient of variability). Diagnosis was estimated by maximizing the Youden index for H/M and washout ratios. Discrimination ability was assessed by the area under the curve (AUC). Sensitivity and specificity were reported, using our thresholds. The parameter with the best diagnostic accuracy was the H/M4h ratio, with a major AUC (0.976 area under the receiver-operating characteristic curve). The threshold was 1.43 with a 95% confidence interval of 1.37-1.50. Using this threshold, the sensitivity and specificity were 93 and 100%. The interobserver and intraobserver variabilities measuring this ratio were 3.2 and 3.1%, respectively. The diagnostic cutoff point for {sup 123}I-MIBG myocardial scintigraphy in a Caucasian population with PD was 1.43 for the H/M4h index, with a good sensitivity and specificity. The technique is easy to use, with a good reproducibility over a range of interpretation expertise. (orig.)

  17. Myocardial scintigraphy using iodine-123 15-(p-Iodophenyl)-3-R, S-methylpentadecanoic acid predicts the response to beta-blocker therapy in patients with dilated cardiomyopathy but does not reflect therapeutic effect

    Energy Technology Data Exchange (ETDEWEB)

    Yoshinaga, Keiichiro; Tahara, Minoru; Torii, Hiroyuki; Akimoto, Masaki [Kagoshima City Medical Association Hopital (Japan); Kihara, Koichi; Tei, Chuwa

    2000-05-01

    Myocardial fatty acid metabolism is disturbed in patients with idiopathic dilated cardiomyopathy. Myocardial scintigraphy using iodine-123 15-(p-iodophenyl)-3-R, S-methylpentadecanoic acid (BMIPP) was used to assess the response to {beta}-blocker therapy in 19 patients with dilated cardiomyopathy. BMIPP myocardial scintigraphy was performed before and 6 months after initiating {beta}-blocker therapy with metoprolol. Cardiac BMIPP uptake was assessed as the total defect score (TDS) and heart-to-mediastinum activity (H/M) ratio. Patients were classified retrospectively as responders with an improvement of at least one functional class (New York Heart Association) or an increase in ejection fraction of {>=}0.10 at 6 months, or as nonresponders meeting neither criterion. Responders had a significantly better pretreatment TDS (p<0.005) and H/M ratio (p<0.0001) than nonresponders. TDS exhibited no significant changes over 6 months in either group (responders: 13.2{+-}3.7 vs 12.5{+-}3.3; nonresponders: 20.8{+-}6.5 vs 20.5{+-}3.0). Responders showed no significant changes in H/M ratio (2.47{+-}0.28 vs 2.43{+-}0.42); paradoxically, nonresponders showed a significant increase from 1.82{+-}0.11 to 2.10{+-}0.19 (p<0.05), suggesting that {beta}-blocker therapy protected the myocardial fatty acid metabolism even in the absence of clinical improvement. BMIPP myocardial scintigraphy provides a prediction of response to {beta}-blocker treatment, but does not reflect the therapeutic effect in responders at 6 months. (author)

  18. Viability after myocardial infarction: can it be assessed within five minutes by low-dose dynamic iodine-123-iodophenylpentadecanoic acid imaging with a multicrystal gamma camera?

    Science.gov (United States)

    Murray, G L; Schad, N; Bush, A J

    1997-04-01

    Although positron emission tomography (PET) assesses myocardial viability (V) accurately, a rapid, inexpensive substitute is needed. Therefore, the authors developed a low-dose (1 mCi) Iodine-123-Iodophenylpentadecanoic Acid (IPPA) myocardial viability scan requiring analysis of only the first three minutes of data acquired at rest with a standard multicrystal gamma camera. Twenty-one patients > 2 weeks after myocardial infarction (MI) (24 MIs, 10 anterior, 14 inferoposterior, 21 akinetic or dyskinetic) had cardiac catheterization and resting IPPA imaging. V was determined by either transmural myocardial biopsy during coronary bypass surgery (12 patients, 14 MIs) or reinjection tomographic thallium scan (9 patients, 10 MIs), and 50% of MIs were viable. The IPPA variables analyzed were: time to initial left ventricular (LV) uptake in the region of interest (ROI), the ratio of three-minute uptake in the ROI to three-minute LV uptake, three-minute clearing (counts/pixel) in the ROI (decrease in IPPA after initial uptake), and three-minute accumulation (increase in IPPA after initial uptake) in the ROI. Rules for detecting V were generated and applied to 10 healthy volunteers to determine normalcy. While three-minute uptake in nonviable MIs was only 67% of volunteers (P or = 13.5 counts/pixel in 10/12 (83%) of viable MIs, and IPPA accumulation > or = 6.75 counts/pixel identified one more viable MI, for a sensitivity for V of 11/12 (92%), with a specificity of 11/12 (92%), and a 100% normalcy rate. The authors conclude low-dose IPPA (five-minute acquisition with analysis of the first three minutes of data) has potential for providing rapid, inexpensive V data after MI. Since newer multicrystal cameras are mobile, IPPA scans can be done in emergency rooms or coronary care units generating information that might be useful in decisions regarding thrombolysis, angioplasty, or bypass surgery.

  19. Clinical usefulness of myocardial iodine-123-15-(p-iodophenyl)-3(R,S)-methyl-pentadecanoic acid distribution abnormality in patients with mitochondrial encephalomyopathy based on normal data file in bull's-eye polar map

    International Nuclear Information System (INIS)

    Takahashi, Nobukazu; Mitani, Isao; Sumita, Shinichi

    1998-01-01

    Visual interpretation of iodine-123-beta-15-(p-iodophenyl)-3(R,S)-methyl-pentadecanoic acid ( 123 I-BMIPP) myocardial images cannot easily detect mild reduction in tracer uptake. Objective assessment of myocardial 123 I-BMIPP maldistributions at rest was attempted using a bull's-eye map and its normal data file for detecting myocardial damage in patients with mitochondrial encephalomyopathy. Six patients, two with Kearns-Sayre syndrome and four with mitochondrial myopathy, encephalopathy, lactic acidosis, and strokelike episodes (MELAS), and 10 normal subjects were studied. Fractional myocardial uptake of 1 23 I-BMIPP was also measured by dynamic static imaging to assess the global myocardial free fatty acid. These data were compared with the cardiothoracic ratio measured by chest radiography and left ventricular ejection fraction assessed by echocardiography. Abnormal cardiothoracic ratio and lower ejection fraction were detected in only one patient with Kearns-Sayre syndrome. Abnormal fractional myocardial uptake was detected in two patients (1.61%, 1.91%), whereas abnormal regional 123 I-BMIPP uptake assessed by the bull's-eye map was detected in five patients (83%). All patients showed abnormal uptake in the anterior portion, and one showed progressive atrioventricular conduction abnormality and systolic dysfunction with extended 123 I-BMIPP abnormal uptake. The results suggest that assessment based on the normal data file in a bull's-eye polar map is clinically useful for detection of myocardial damage in patients with mitochondrial encephalomyopathy. (author)

  20. Norepinephrine, {beta}-adrenoceptor and {sup 123}I-MIBG myocardial scintigram in patients with congestive heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Kenichi; Miyajima, Seiichi; Kusano, Yoriko; Tanabe, Naohito [Tsubame Rosai Hospital, Niigata (Japan); Nagatomo, Takafumi

    1997-06-01

    Authors studied the relationships of norepinephrine (NE), {beta}-adrenoceptor and {sup 123}I-MIBG (meta-iodo-benzylguanidine) uptake in 26 patients with dilated cardiomyopathy or valvulitis. Blood NE concentrations were determined by high performance liquid chromatography in those patients and 10 healthy volunteers, and myocardial NE, in 7 patients and 5 cases without the congestive heart failure. The amounts of beta-receptors in lymphocytes of 21 patients and 7 volunteers and in myocardium obtained at autopsy of 3 patients and 3 other cases were estimated by the radioligand binding assay. Planar and SPECT images were taken at 15 min and 3 hr post intravenous administration of 111 MBq of {sup 123}I-MIBG. In the planar and SPECT images, the ratio heart/mediastinum (H/M) and MIBG uptake were computed respectively. Blood flow was evaluated by {sup 201}Tl scintigraphy. In patients with congestive heart failure, blood NE concentration was elevated and the number of lymphocytic and myocardial receptors was decreased. The H/M ratio was low. Low MIBG uptake was seen at the posterior to lateral wall. (K.H.)

  1. Investigation of alumino-phosphate glasses for iodine conditioning

    International Nuclear Information System (INIS)

    Lemesle, T.

    2013-01-01

    Iodine 129 is a long-lived intermediate level radioactive waste, which is currently managed by isotopic dilution. In view of an alternative management by geological disposal, we aimed at developing phosphate glasses of the AgI-Ag 2 O-P 2 O 5 -Al 2 O 3 system, elaborated at low temperature and without iodine volatilization. Alumina is expected to induce crosslinking of the phosphate network and thus to improve the thermal and chemical properties. To define a glass composition that meets the specifications, we varied the level of iodine, the Ag 2 O/P 2 O 5 ratio and alumina content. For 1 g.cm -3 of iodine, SEM-EDS observations indicate that alumina solubility is limited to 0.5% mol., independently of Ag 2 O/P 2 O 5 ratio. The structural study by 31 P, 27 Al and 109 Ag MAS NMR, shows that aluminum adopts an octahedral coordination that effectively contributes to the crosslinking of the glassy network and iodine is incorporated without clustering. 31 P- 27 Al NMR correlations confirmed the presence of an alumino-phosphate network, and 31 P- 31 P correlations indicate that iodine does not change the connectivity of the glass network. The glass composition 28,8AgI-44,2Ag 2 O-26,5P 2 O 5 -0,5Al 2 O 3 presents the best compromise between the level of incorporation of iodine and the chemical durability, has a glass transition temperature of 123 C and an initial alteration rate in pure water at 50 C of 6 g.m -2 .d -1 . The long-term behavior of this glass is controlled by a post-alteration structure based on pyrophosphate, which holds nearly 80% of the initial iodine. (author) [fr

  2. Determination of iodide by volumetric titration in support of the oil eletrolabeling with {sup 123}I

    Energy Technology Data Exchange (ETDEWEB)

    Kenup-Cantuaria, Hericka O.H.; Brandao, Luis E.B., E-mail: hkenup@ien.gov.br, E-mail: brandao@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Silva, Ademir X., E-mail: ademir@nuclear.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear

    2015-07-01

    The accuracy in measuring flow rate in pipelines is essential task to control various technical parameters in an industrial plant in oil industry and its derivatives. For this reason, it becomes increasingly widespread the uses of organic molecules labeled with radioactive isotopes mainly because of the wide possibility in use of different radioisotopes also due to the new labeling techniques. This paper presents a study to develop an electrochemical technique for oil labeling with iodine -123 and to determine the yield of production by measuring the concentration of iodide (I{sup -}) during this process. The volumetric titration technique was applied as a basis for quantitative and qualitative measures to monitor the labeling process. The results indicate the technical proposal as a viable alternative for monitoring electro labeling process of lubricating oils with iodine -123. (author)

  3. Production of high purity iodine-123 from xenon-124 at energies between 15 and 34 MeV

    International Nuclear Information System (INIS)

    Firouzbakht, M.L.; Teng Renrui; Schlyer, D.J.; Wolf, A.P.

    1987-01-01

    The production of I-123 from the proton bombardment of isotopically enriched Xe-124 is reported over the energy range of 15 to 34 MeV via the 124 Xe (p,pn) 123 Xe (β + , 2.1 hr) → 123 I and 124 Xe (p,2n) 123 Cs (β + , 6 min) → 123 Xe (β + , 2.1 hr) → 123 I pathways. The thick target yields for this target are tabulated and compared to theoretical cross-section calculations of the nuclear reactions leading to the production of Xe-123. The radiochemical purity of the I-123 is greater than 99.9% and the contamination of I-125 is below detectable limits (< 0.1%) at 6.6 hrs after the end of bombardment. (orig.)

  4. Structural changes in Parkinson's disease. Voxel-based morphometry and diffusion tensor imaging analyses based on 123I-MIBG uptake

    International Nuclear Information System (INIS)

    Kikuchi, Kazufumi; Hiwatashi, Akio; Togao, Osamu; Yamashita, Koji; Somehara, Ryo; Kamei, Ryotaro; Baba, Shingo; Honda, Hiroshi; Yamaguchi, Hiroo; Kira, Jun-ichi

    2017-01-01

    Patients with Parkinson's disease (PD) may exhibit symptoms of sympathetic dysfunction that can be measured using 123 I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy. We investigated the relationship between microstructural brain changes and 123 I-MIBG uptake in patients with PD using voxel-based morphometry (VBM) and diffusion tensor imaging (DTI) analyses. This retrospective study included 24 patients with PD who underwent 3 T magnetic resonance imaging and 123 I-MIBG scintigraphy. They were divided into two groups: 12 MIBG-positive and 12 MIBG-negative cases (10 men and 14 women; age range: 60-81 years, corrected for gender and age). The heart/mediastinum count (H/M) ratio was calculated on anterior planar 123 I-MIBG images obtained 4 h post-injection. VBM and DTI were performed to detect structural differences between these two groups. Patients with low H/M ratio had significantly reduced brain volume at the right inferior frontal gyrus (uncorrected p < 0.0001, K > 90). Patients with low H/M ratios also exhibited significantly lower fractional anisotropy than those with high H/M ratios (p < 0.05) at the left anterior thalamic radiation, the left inferior fronto-occipital fasciculus, the left superior longitudinal fasciculus, and the left uncinate fasciculus. VBM and DTI may reveal microstructural changes related to the degree of 123 I-MIBG uptake in patients with PD. (orig.)

  5. Usefulness of Cardiac MIBG Scintigraphy, Olfactory Testing and Substantia Nigra Hyperechogenicity as Additional Diagnostic Markers for Distinguishing between Parkinson's Disease and Atypical Parkinsonian Syndromes.

    Directory of Open Access Journals (Sweden)

    Hiroaki Fujita

    Full Text Available We aimed to evaluate the utility of the combined use of cardiac 123I-metaiodobenzylguanidine (MIBG scintigraphy, olfactory testing, and substantia nigra (SN hyperechogenicity on transcranial sonography (TCS in differentiating Parkinson's disease (PD from atypical parkinsonian syndromes (APSs, such as multiple system atrophy (MSA and progressive supranuclear palsy (PSP.Cardiac MIBG scintigraphy, card-type odor identification testing (Open Essence (OE, Wako, Japan, and TCS were performed with 101 patients with PD and 38 patients with APSs (MSA and PSP. Receiver operating characteristic (ROC curve analysis was used to assess the sensitivity and specificity of these batteries for diagnosing PD from APSs. The diagnostic accuracy of the three tests was also assessed among patients at the early disease stage (drug-naïve patients with a disease duration of 3 years or less.In differentiating PD from APSs, the area under the ROC curve was 0.74 (95% CI, 0.65-0.83, 0.8 (95% CI, 0.73-0.87, and 0.75 (95% CI, 0.67-0.82 for TCS, cardiac MIBG scintigraphy, and olfactory testing, respectively. The diagnostic sensitivity and specificity were 53.1% and 91.7%, respectively, for TCS, 70.3% and 86.8%, respectively, for cardiac MIBG scintigraphy, 58.4% and 76.3%, respectively, for OE. Among early-stage patients, sensitivity and specificity were 50.0% and 93.8%, respectively, for TCS, 57.1% and 87.5%, respectively, for cardiac MIBG scintigraphy, and 54.8% and 79.2%, respectively, for OE. At least one positive result from 3 tests improved sensitivity (86.1% but decreased specificity (63.2%. In contrast, at least 2 positive results from 3 tests had good discrimination for both early-stage patients (50.0% sensitivity and 93.8% specificity and patients overall (57.8% sensitivity and 95.8% specificity. Positive results for all 3 tests yielded 100% specificity but low sensitivity (25%.At least 2 positive results from among TCS, cardiac MIBG scintigraphy, and olfactory

  6. Structural changes in Parkinson's disease. Voxel-based morphometry and diffusion tensor imaging analyses based on {sup 123}I-MIBG uptake

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Kazufumi; Hiwatashi, Akio; Togao, Osamu; Yamashita, Koji; Somehara, Ryo; Kamei, Ryotaro; Baba, Shingo; Honda, Hiroshi [Kyushu University, Department of Clinical Radiology, Graduate School of Medical Sciences, Fukuoka (Japan); Yamaguchi, Hiroo; Kira, Jun-ichi [Kyushu University, Department of Neurology, Graduate School of Medical Sciences, Fukuoka (Japan)

    2017-12-15

    Patients with Parkinson's disease (PD) may exhibit symptoms of sympathetic dysfunction that can be measured using {sup 123}I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy. We investigated the relationship between microstructural brain changes and {sup 123}I-MIBG uptake in patients with PD using voxel-based morphometry (VBM) and diffusion tensor imaging (DTI) analyses. This retrospective study included 24 patients with PD who underwent 3 T magnetic resonance imaging and {sup 123}I-MIBG scintigraphy. They were divided into two groups: 12 MIBG-positive and 12 MIBG-negative cases (10 men and 14 women; age range: 60-81 years, corrected for gender and age). The heart/mediastinum count (H/M) ratio was calculated on anterior planar {sup 123}I-MIBG images obtained 4 h post-injection. VBM and DTI were performed to detect structural differences between these two groups. Patients with low H/M ratio had significantly reduced brain volume at the right inferior frontal gyrus (uncorrected p < 0.0001, K > 90). Patients with low H/M ratios also exhibited significantly lower fractional anisotropy than those with high H/M ratios (p < 0.05) at the left anterior thalamic radiation, the left inferior fronto-occipital fasciculus, the left superior longitudinal fasciculus, and the left uncinate fasciculus. VBM and DTI may reveal microstructural changes related to the degree of {sup 123}I-MIBG uptake in patients with PD. (orig.)

  7. Basic studies on the hepatobiliary scintigraphy with 123I-rose bengal

    International Nuclear Information System (INIS)

    Narabayashi, Isamu; Ito, Yasuhiko; Otsuka, Nobuaki; Muranaka, Akira; Konno, Katsunobu.

    1979-01-01

    The purpose of this investigation is to evaluate the values of 123 I-rose bengal. sup(99m)Tc-labels for the hepatobiliary radiopharmaceutical are not fully satisfied because of greater urinary excretion, especially in cases of hyperbilirubinemia. 123 I is a lower gamma ray energy emitter more suitable for imaging and has a short half life with 13 hours. Commercially obtained rose bengal was purified using Sephadex G-25 column on gelfiltration. 123 I-rose bengal was prepared using iodine exchange reaction between nonradioactive rose bengal and Na 123 I. Radiochemical purity of 123 I-rose bengal was examined by paper chromatography. Biological distribution of 123 I-rose bengal in rabbits at 1 hours after intravenous injection indicated that the tracer was cleared from the blood to the liver, thereafter excreted into the small intestine through the common bile duct. Hepatic uptake and excretion of activity has been measured for 60 minutes using a scintillation camera in conjunction with a VTR system. There existed no significant relative to those of 131 I-rose bengal. Serial scintigraphic images showed satisfactorily better images even in a rabbit with complete obstructive jaundice. (author)

  8. Do iodinated fatty acids undergo a nonspecific deiodination in the myocardium

    International Nuclear Information System (INIS)

    Cuchet, P.; Demaison, L.; Bontemps, L.; Keriel, C.; Mathieu, J.P.; Pernin, C.; Batille, D.M.; Riche, F.; Vidal, M.; Oomet, M.; Grenoble-1 Univ., 38 - La Tronche; Grenoble-1 Univ., 38 - Saint-Martin-d'Heres

    1985-01-01

    The intracellular and subcellular distribution of 16-( 123 I)-iodo-9-hexadecenoic acid were studied in isolated rat hearts, perfused with or without glucose. At various time intervals after injection, cardiac lipids were extracted and the activity was determined for all fractions and all lipid classes. The total cardiac activity was maximal within 1 min postinjection and most of the activity was in the aqueous phase. The presence of glucose in the perfusion medium induced an increase of total cardiac and organic fraction activities. In the latter fraction, activity was very low for FFA, but high for triglycerides (TG), and especially polar lipids. The presence of an exogenous substrate, led to a more active esterification of fatty acids. Coronary effluent analysis showed, in the hydrophilic phase, a lower activity spike in the presence than in the absence of glucose. In the mitochondrial fraction most activity occurred in the organic phase, especially as polar lipids. In the nonmitochondrial fraction, activity was much higher in the aqueous phase. A 90 s postinjection of 1- 14 C-palmitic acid, over 80% of the myocardial activity was found in the hydrophilic fraction, which indicates, as for the iodo-fatty acid (IFA), an immediate and important oxidation, especially without glucose. These data seem to prove that IFA is taken up by the myocardial cell, subsequently enters the mitochondria and, without an early deiodination, is oxidized with iodide release. Changes in IFA metabolism, consecutive to modifications of glucose concentration in the perfusion medium can be observed by external detection of the myocardial activity curve. ω-Iodinated fatty acids do not undergo a nonspecific deiodination and are therefore well suited for an external study of myocardial metabolism. (orig.)

  9. Heart failure and 1231-M.I.B.G. scintigraphy: comeback; Scintigraphie cardiaque a la 1231-metaiodobenzylguanidine et cardiomyopathies: le retour

    Energy Technology Data Exchange (ETDEWEB)

    Agostini, D.; Hugentobler, A.; Costo, S.; Bouvard, G. [Centre Hospitalier Universitaire Cote de Nacre, Service de Medecine Nucleaire, 14 - Caen (France); Manrique, A. [Centre de Lutte Contre le Cancer Henri-Becquerel, Service de Medecine Nucleaire, 76 - Rouen (France); Sabatier, R.; Grollier, G. [Centre Hospitalier Universitaire Cote de Nacre, Service de Cardiologie, 14 - Caen (France); Belin, A. [Hopital de Trouville, Service de Readaptation Cardiaque, 14 - Trouville (France)

    2007-09-15

    Congestive heart failure is a often associated with an impairment of sympathetic nervous system, i.e., global hyperactivity and regional impairment of adrenergic system. Cardiac {sup 123}I-meta-iodo-benzyl-guanidine (M.I.B.G.) scintigraphy is a radionuclide technique which can explore the presynaptic adrenergic function. Cardiac fixation of M.I.B.G. is decreased in congestive heart failure, reflecting a reduction of norepinephrine uptake by the myocardial presynaptic ending nerves. The impairment of presynaptic function is early and actually involved in the pathogenesis of cardiac failure. Cardiac M.I.B.G. scintigraphy is a useful tool to explore the myocardial adrenergic stores in patients with congestive heart failure. (authors)

  10. Autoradiolytic decomposition and reductant-free sodium sup 124 I- and sup 123 I-iodide

    Energy Technology Data Exchange (ETDEWEB)

    Sajjad, M.; Lambrecht, R.M.; Bakr, S.A. (King Faisal Specialist Hospital and Research Centre, Riyadh (Saudi Arabia). Radionuclide and Cyclotron Operations)

    1990-01-01

    The presence of salts and metal cations in {sup 124}I- and {sup 123}I-sodium iodide solutions separated from {sup 124}Te targets promots autoradiolytic decomposition of iodide to several different iodine species dependent upon the chemical environment. The stabilization of the radioiodine as iodide by removal of trace salts and trace metal cations and in the absence of reducing agents is described. The high specific activity {sup 123}I- and {sup 124}I-iodide is suitable for labeling antibodies, proteins and radiopharmaceuticals. (orig.).

  11. Production of no-carrier-added {sup 123}I via heavy-ion activation of natural antimony oxide

    Energy Technology Data Exchange (ETDEWEB)

    Maji, S. [The Univ. of Burdwan (India). Dept. of Chemistry; Lahiri, S. [Saha Institute of Nuclear Physics, Kolkata (India). Chemical Sciences Div.

    2007-07-01

    Activation of natural Sb{sub 2}O{sub 3} with 48 MeV {sup 7}Li{sup 3+} beam results in the formation of no-carrier-added {sup 123}I in the matrix along with the radionuclides {sup 123,125}Xe and {sup 122}Sb. The {sup 123}I yield amounts to about 400 kBq/{mu}Ah and the radionuclidic impurity of {sup 124}I to {proportional_to}1.2% of {sup 123}I. Attempts to separate no-carrier-added iodine from bulk antimony target involved liquid-liquid extraction with TOA and HDEHP as well as precipitation of Sb{sub 2}S{sub 3} with thioacetamide. The precipitation technique was found to be the most effective for quantitative separation of {sup 123}I from the bulk antimony oxide target. (orig.)

  12. Development of I-123-labeled amines for brain studies: localization of I-123 iodophenylalkyl amines in rat brain

    International Nuclear Information System (INIS)

    Winchell, H.S.; Baldwin, R.M.; Lin, T.H.

    1980-01-01

    Localization in rat brain of forty iodophenylalkyl amines labeled with I-123 was evaluated in an attempt to develop I-123-labeled amines useful for brain studies. For the amines studied, the highest activity in brain and the brain-to-blood activity ratios ranked p > m > o as related to iodine position on the benzene ring: for alkyl groups the rank order was α-methylethyl > ethyl > methyl > none; for N additions it was single lipophilic group > H > two lipophilic groups. It is suggested that introduction of a halogen into the ring structure of many amines results in greater concentration of the agent in brain than is seen with the nonhalogenated parent compound. The agent N-isopropyl-p-iodoamphetamine was chosen for further study because, in the rat, it showed high brain activity (1.57%/g) and brain-blood ratio (12.6) at 5 min

  13. /sup 123/I production at the Milan AVF cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Acerbi, E; Birattari, C; Castiglioni, M; Resmini, F [Milan Univ. (Italy). Istituto di Fisica

    1976-01-01

    A program is described to make available quantities of at least 20 mCi of /sup 123/I per irradiation, on a weekly routine basis to medical users at the Clinical Physiology Laboratory of Pisa. Contaminants such as /sup 124/I should be kept below 3%. The isotope, or compounds of it, like iodo-antipyrine and ortho-iodohippuric acid, were to be used as scanning agents for pancreas, kidneys, thyroid and for the detection of the aqueous content in the pulmonary region. The production of /sup 123/I from enriched /sup 124/Te is described. Preliminary experiments on a distillation separation of iodine from the Te target have been performed and the method seems promising in comparison to the time-consuming chemical separation technique.

  14. Contrast-induced encephalopathy following cardiac catheterization.

    Science.gov (United States)

    Spina, Roberto; Simon, Neil; Markus, Romesh; Muller, David Wm; Kathir, Krishna

    2017-08-01

    To describe the epidemiology, pathophysiology, clinical presentation, and management of contrast-induced encephalopathy (CIE) following cardiac catheterization. CIE is an acute, reversible neurological disturbance directly attributable to the intra-arterial administration of iodinated contrast medium. The PubMed database was searched and all cases in the literature were retrieved and reviewed. 52 reports of CIE following cardiac catheterization were found. Encephalopathy, motor and sensory disturbances, vision disturbance, opthalmoplegia, aphasia, and seizures have been reported. Transient cortical blindness is the most commonly reported neurological syndrome, occurring in approximately 50% of cases. The putative mechanism involves disruption of the blood brain barrier and direct neuronal injury. Contrast-induced transient vasoconstriction has also been implicated. Symptoms typically appear within minutes to hours of contrast administration and resolve entirely within 24-48 hr. Risk factors may include hypertension, diabetes mellitus, renal impairment, the administration of large volumes of iodinated contrast, percutaneous coronary intervention or selective angiography of internal mammary grafts, and previous adverse reaction to iodinated contrast. Characteristic findings on cerebral imaging include cortical and sub-cortical contrast enhancement on computed tomography (CT). Imaging findings in CIE may mimic subarachnoid hemorrhage or cerebral ischemia; the Hounsfield scale on CT and the apparent diffusion coefficient on magnetic resonance imaging (MRI) are useful imaging tools in distinguishing these entities. In some cases, brain imaging is normal. Prognosis is excellent with supportive management alone. CIE tends to recur, although re-challenge with iodinated contrast without adverse effects has been documented. CIE is an important clinical entity to consider in the differential diagnosis of stroke following cardiac catheterization. Given that prognosis is

  15. [Nuclear cardiology with new radiopharmaceuticals].

    Science.gov (United States)

    Bunko, H

    1994-08-01

    In the field of nuclear cardiology, 99mTc labeled myocardial perfusion agents such as MIBI, Tetrofosmin and Teboroxime, 111In-antimyosin for imaging of myocardial necrosis, 123I-betamethyl-iodophenylpentadecanoic acid (BMIPP) for imaging of myocardial fatty acid metabolism and 123I-metaiodobenzylguanidine (MIBG) for imaging of myocardial adrenergic function are introduced recently in Japan. Improved image quality and simultaneous evaluation of myocardial perfusion, function and wall motion can be obtained with use of 99mTc labeled myocardial perfusion agents. 111In-antimyosin enables specific imaging of myocardial necrosis which leads to the use for wide variety of heart diseases. Discrepancy of the myocardial perfusion and metabolism in case of stunned myocardium or cardiomyopathy can be evaluated by 123I-BMIPP in conjunction with perfusion agent. Recently wide variety of diseases which may have cardiac adrenergic abnormality are targeted for 123I-MIBG imaging. These new radiopharmaceuticals are expected to be powerful tool for evaluation of the pathophysiology including severity and prognosis and evaluation of the etiology of the various heart diseases.

  16. Effect of Switching from Cilnidipine to Azelnidipine on Cardiac Sympathetic Nerve Function in Patients with Heart Failure Preserved Ejection Fraction.

    Science.gov (United States)

    Kiuchi, Shunsuke; Hisatake, Shinji; Kabuki, Takayuki; Oka, Takashi; Dobashi, Shintaro; Fujii, Takahiro; Ikeda, Takanori

    2018-01-27

    Cardiac sympathetic nerve activity is known to play a key role in the development and progression of heart failure (HF). Azelnidipine, an L-type calcium channel blocker (CCB), inhibits the sympathetic nerve activity of the central system. In contrast, cilnidipine, an N-type CCB, inhibits the sympathetic nerve activity of the peripheral system. CCBs are recommended as class IIa in patients with HF preserved ejection fraction (HFpEF); however, there are no comparative data on the difference in effect of cilnidipine and azelnidipine in patients with HFpEF and hypertension. We investigated the difference in effect of azelnidipine compared with cilnidipine in patients with HFpEF. Twenty-four consecutive HF patients who received angiotensin II type1a receptor blocker and beta blocker from April 2013 to January 2015 were enrolled. Cilnidipine was switched to azelnidipine during the follow-up period. Blood pressures, heart rate, blood tests, echocardiography, and 123 I-metaiodobenzylguanidine (MIBG) cardiac-scintigraphy were measured before and after 6 months from azelnidipine administration. B-type natriuretic peptide tended to decrease after switching to azelnidipine; however, there were no significant differences between the pre-state and post-state (pre-state: 118.5 pg/mL and post-state: 78.4 pg/mL, P = 0.137). Other laboratory findings, including catecholamine, also did not change significantly. In echocardiography, there were no significant differences in systolic and diastolic functions at the pre-state and post-state. As for MIBG, there were no significant changes in heart/mediastinum ratio. However, washout rate was significantly reduced (pre-state: 42.9 and post-state: 39.6, P = 0.030). Azelnidipine improved the dysfunction of cardiac sympathetic nerve activity compared with cilnidipine in patients with HFpEF.

  17. Effects of Different Containers on Radioactivity Measurements using a Dose Calibrator with Special Reference to 111In and 123I.

    Science.gov (United States)

    Inoue, Yusuke; Abe, Yutaka; Kikuchi, Kei; Miyatake, Hiroki; Watanabe, Atsushi

    2017-01-01

    Low-energy characteristic x-rays emitted by 111 In and 123 I sources are easily absorbed by the containers of the sources, affecting radioactivity measurements using a dose calibrator. We examined the effects of different containers on the estimated activities. The radioactivities of 111 In, 123 I, 201 Tl, and 99m Tc were measured in containers frequently employed in clinical practice in Japan. The 111 In measurements were performed in the vials A and B of the 111 In-pentetreotide preparation kit and in the plastic syringe. The activities of 123 I-metaiodobenzylguanidine and 201 Tl chloride were measured in the prefilled glass syringes and plastic syringes. The milking vial, vial A, vial B, and plastic syringe were used to assay 99m Tc. For 111 In and 123 I, measurements were performed with and without a copper filter. The filter was inserted into the well of the dose calibrator to absorb low-energy x-rays. The relative estimate was defined as the ratio of the activity estimated with the dose calibrator to the standard activity. The estimated activities varied greatly depending on the container when 111 In and 123 I sources were assayed without the copper filter. The relative estimates of 111 In were 0.908, 1.072, and 1.373 in the vial A, vial B, and plastic syringe, respectively. The relative estimates of 123 I were 1.052 and 1.352 in the glass syringe and plastic syringe, respectively. Use of the copper filter eliminated the container-dependence in 111 In and 123 I measurements. Container-dependence was demonstrated in neither 201 Tl nor 99m Tc measurements. The activities of 111 In and 123 I estimated with a dose calibrator differ greatly among the containers. Accurate estimation may be attained using the container-specific correction factor or using the copper filter.

  18. SPET imaging of central muscarinic acetylcholine receptors with iodine-123 labelled E-IQNP and Z-IQNP

    Energy Technology Data Exchange (ETDEWEB)

    Nobuhara, K.; Farde, L.; Halldin, C.; Karlsson, P.; Swahn, C.G.; Olsson, H.; Sedvall, G. [Dept. of Clinical Neuroscience, Psychiatry Section, Karolinska Hospital, Stockholm (Sweden); Bergstroem, K.A. [Dept. of Clinical Physiology, Kuopio University Hospital, Kuopio (Finland); Larsson, S.A.; Schnell, P.-O. [Dept. of Radiation Physics, Karolinska Hospital, Stockholm (Sweden); McPherson, D.W. [Oak Ridge National Laboratory (ORNL), Nuclear Medicine Group, TN (United States); Savonen, A.; Hiltunen, J. [MAP Medical Technologies Oy, Tikkakoski (Finland)

    2001-01-01

    1-Azabicyclo[2.2.2]oct-3-yl {alpha}-hydroxy-{alpha}-(1-iodo-1-propen-3-yl)-{alpha}-phenylacetate (IQNP) is a muscarinic acetylcholine receptor (mAChR) antagonist and the racemic ligand contains eight stereoisomers. In a single-photon emission tomography (SPET) study in monkeys we recently confirmed that [{sup 123}I]E-(R,R)-IQNP ([{sup 123}I]E-IQNP) is a radioligand with modest selectivity for the M{sub 1} and M{sub 4} subtypes, whereas [{sup 123}I]Z-(R,R)-IQNP ([{sup 123}I]Z-IQNP) is non-subtype selective. In the present SPET study, E- and Z-IQNP were examined in human subjects. SPET examination was performed on three male subjects after i.v. injection of [{sup 123}I]E-IQNP and in another three after i.v. injection of [{sup 123}I]Z-IQNP. The binding potential (BP) for [{sup 123}I]E-IQNP was calculated using several quantitative approaches with the cerebellum as a reference region. High-performance liquid chromatography was used to measure radioligand metabolism in plasma. Following [{sup 123}I]E-IQNP, the radioactivity was high in the neocortex and striatum, intermediate in the thalamus and low in the pons and cerebellum, which is consistent with the rank order for the regional density of M{sub 1} and M{sub 4} subtypes in vitro. For all regions, peak equilibrium was identified within the 48-h data acquisition. The simplified reference tissue approach using SPET data from 0 to 48 h was the most reliable in this limited series of subjects. Following injection of [{sup 123}I]Z-IQNP, radioactivity was high in the neocortex and striatum, intermediate in the thalamus and pons and low in the cerebellum, which is in agreement with the density of M{sub 1}, M{sub 2} and M{sub 4} subtypes as measured in vitro. Quantitative analyses provided indirect support for specific M{sub 2} binding of Z-IQNP in the cerebellum. The high selectivity of [{sup 123}I]E-IQNP for M{sub 1} and M{sub 4} receptors allowed the use of cerebellum as a reference region devoid of specific binding, and

  19. Brain SPECT with iodine-123-amphetamine in amyotrophic lateral sclerosis

    International Nuclear Information System (INIS)

    Boettger, I.G.; Ludolph, A.C.; Elger, C.E.; Lottes, G.

    1988-01-01

    The study of 17 patients with ALS by 123 I-amphetamine (BIMP) SPECT revealed reduced CBF/amphetamine uptake correlation with the clinical status and course of the disease. ALS appears to involve fronto-temporal structures/functions in the early stage finally leading to generalization with the exclusion of the cerebellum. Thus, in ALS an involvement of also other than only motor cerebral structures/functions, which may be reversible, has to be considered. (orig.)

  20. Clinical usefulness of {sup 123}I-BMIPP myocardial SPECT in collagen disease

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Kazuki; Zen, Kan [Asahi Univ., Gifu (Japan). Murakami Memorial Hospital; Sugihara, Hiroki (and others)

    2000-07-01

    This study was designed to evaluate the clinical usefulness of {sup 123}I-BMIPP myocardial SPECT for detecting cardiac involvement in patients with collagen disease. We studied 12 patients with systemic lupus erythematosus (SLE), 8 with progressive systemic sclerosis (PSS), 6 with polymyositis/dermatomyositis (PM/DM) and 3 with allergic granulomatosis and angiitis (AGA). A 111 MBq of {sup 123}I-BMIPP was intravenously injected at rest, and SPECT images were obtained at 15 min after the injection. Seven of 12 SLE, 6 of 8 PSS, 3 of 6 PM/DM and all 3 AGA patients showed an abnormal tracer uptake. The left ventricular ejection fraction was inversely correlated with a BMIPP abnormality. The regional wall motion abnormality was reduced in regions with reduced tracer uptake. These findings suggest that {sup 123}I-BMIPP imaging could be useful for assessment of cardiac involvement in patients with collagen disease. (author)

  1. Reduced cortical distribution volume of iodine-123 iomazenil in Alzheimer's disease as a measure of loss of synapses

    International Nuclear Information System (INIS)

    Soricelli, A.; Postiglione, A.; Grivet-Fojaja, M.R.; Mainenti, P.P.; Discepolo, A.; Varrone, A.; Salvatore, M.; Lassen, N.A.

    1996-01-01

    Iodine-123 labelled iomazenil (IMZ) is a specific tracer for the GABA A receptor, the dominant inhibitory synapse of the brain. The cerebral distribution volume (V d ) of IMZ may be taken as a quantitative measure of these synapses in Alzheimer's disease (AD), where synaptic loss tends indiscriminately to affect all cortical neurons, albeit more so in some areas than in others. In this pilot study we measured V d in six patients with probable AD and in five age-matched controls using a brain-dedicated single-photon emission tomography scanner allowing all cortical levels to be sampled simultaneously. Reduced values were found in all regions except in the occipital (visual) cortex. In particular, temporal and parietal cortex V d was significantly (P d averaged 69 ml/ml in normals and 51 ml/ml in AD, and parietal V d averaged 71 ml/ml in normals and 48 ml/ml in AD. These results accord well with emission tomographic studies of blood flow or labelled glucose. This supports the idea that while only measuring a subpopulation of synapses, the IMZ method reflects synaptic loss and hence functional loss in AD. The method constitutes an in vivo version of synaptic quantitation that in histopathological studies has been shown to correlated closely with the mental deterioration in AD. (orig.)

  2. [Myocardial uptake ratio of iodine-123 labeled beta-methyl iodophenylpentadecanoic acid (123I-BMIPP) in relation to the concentration of the substrates of energy].

    Science.gov (United States)

    Tsuchimochi, S; Tamaki, N; Kawamoto, M; Tadamura, E; Fujita, T; Nohara, R; Matsumori, A; Sasayama, S; Yonekura, Y; Konishi, J

    1995-06-01

    Iodine-123 beta-methyl iodophenylpentadecanoic acid (BMIPP) has been used for evaluating myocardial fatty acid metabolism in vivo. The whole body BMIPP imaging was acquired in 26 patients (11 with HCM, 11 with CAD and 4 with DCM) to calculate % uptake in the myocardium and to correlate its uptake with biochemical data, including blood sugar (BS), nonesterified fatty acid (NEFA) and insulin in the blood. BMIPP was administered at rest with overnight fasting state, and the anterior and posterior whole body imaging was performed one hour later. The background corrected whole myocardial counts were calculated to obtain %BMIPP uptake. In addition, the heart to mediastinum count ratio (H/M ratio) was calculated from the mean counts in the heart and the upper mediastinum in the anterior view. The %BMIPP uptake was 3.70 +/- 1.22% and H/M ratio was 2.30 +/- 0.23. The patients with DCM showed higher %BMIPP uptake values (DCM = 5.58 +/- 0.67% vs. CAD = 3.09 +/- 0.97% and HCM = 3.63 +/- 0.86%, both p < 0.01), but similar values of H/M ratio with other patients (DCM = 2.43 +/- 0.20, CAD = 2.22 +/- 0.25 and HCM = 2.32 +/- 0.20). Although the biochemical data varied at the time of the tracer administration, they were not significantly correlated with the %BMIPP uptake or H/M ratio. However, there was a significant correlation between %BMIPP uptake and H/M ratio with the correlation coefficient of 0.80 (p < 0.001). We conclude that the myocardial uptake of BMIPP is not influenced by the plasma substrate level under the fasting state.

  3. Myocardial uptake ratio of iodine-123 labeled beta-methyl iodophenylpentadecanoic acid (123I-BMIPP) in relation to the concentration of the substrates of energy

    International Nuclear Information System (INIS)

    Tsuchimochi, Shinsaku; Tamaki, Nagara; Kawamoto, Masahide

    1995-01-01

    Iodine-123 beta-methyl iodophenylpentadecanoic acid (BMIPP) has been used for evaluating myocardial fatty acid metabolism in vivo. The whole body BMIPP imaging was acquired in 26 patients (11 with HCM, 11 with CAD and 4 with DCM) to calculate % uptake in the myocardium and to correlate its uptake with biochemical data, including blood sugar (BS), nonesterified fatty acid (NEFA) and insulin in the blood. BMIPP was administered at rest with overnight fasting state, and the anterior and posterior whole body imaging was performed one hour later. The background corrected whole myocardial counts were calculated to obtain %BMIPP uptake. In addition, the heart to mediastinum count ratio (H/M ratio) was calculated from the mean counts in the heart and the upper mediastinum in the anterior view. The %BMIPP uptake was 3.70±1.22% and H/M ratio was 2.30±0.23. The patients with DCM showed higher %BMIPP uptake value (DCM=5.58±0.67% vs. CAD=3.09±0.97% and HCM=3.63±0.86%, both p<0.01), but similar values of H/M ratio with other patients (DCM=2.43±0.20, CAD=2.22±0.25 and HCM=2.32±0.20). Although the biochemical data varied at the time of the tracer administration, they were not significantly correlated with the %BMIPP uptake or H/M ratio. However, there was a significant correlation between %BMIPP uptake and H/M ratio with the correlation coefficient of 0.80 (p<0.001). We conclude that the myocardial uptake of BMIPP is not influenced by the plasma substrate level under the fasting state. (author)

  4. Comparison of 24 hr total body radio-iodine retention for hypothyroid vs. thyrogen (rhTSH) stimulated whole body surveillance scan

    International Nuclear Information System (INIS)

    Jana, S.; Young, I.; Bukberg, P.; Luo, J.Q.; Dakhel, M.; Heiba, S.; El-Zeftawy, H.; Abdel-Dayem, H.M.

    2002-01-01

    Objective: Recently rhTSH has been used for WBS to avoid hypothyroid symptoms from T4/T3 withdrawal. There is limited data available in the current literature comparing total body radio-iodine clearance between hypothyroid pts and pts receiving rhTSH. Significant differences in radio-iodine clearance may influence the dose of radio-iodine required for diagnostic scanning or treatment of pts on a rhTSH protocol. Methods: To retrospectively compare the 24 hr total body I-123 retention in thyroid cancer pts who were made hypothyroid in preparation for radio-iodine scanning with the I-123 retention in pts who received thyrogen (rhTSH) but were maintained on thyroid hormone replacement. Inclusion criteria were as follows: Histologically diagnosed well diff. thyroid Ca s/p surgery and I-131 Rx in the past who were clinically disease free at the time of scanning. No abn. visible I-123 uptake on WBS and 24 hr neck uptake ≤ 1%. Tg level ≤ 2ng off T4/T3 or ≤ 2ng increase from basal level after rhTSH. Anti-Tg Ab negative. Serum Creatine ≤ 1.4 mg/dl. Serum ALT < 35, AST < 35. Total 78 pts were divided into the following 3 groups (Gp): Gp-1 (29 pts) received 2 IM inj. Of 0.9 mg rhTSH 24 and 48 hrs prior to oral dose of 10 mCi I-123. Gp-2 (30 pts) followed hypothyroid protocol i.e., off T4 ≥ 4 wks or T3 ≥ 10 days in order to achieve TSH ≥ 30 MIU/L. The dose of I-123 was 5 mCi. Gp-3 (19 pts) similar to Gp-2 i.e., hypothyroid but scanned using 10 mCi of I-123. Imaging protocol: Pts were scanned 4 hrs and 24 hrs after I-123 administration in a dual head gamma camera for 30 mins. Total body and neck counting were obtained from the geometric mean of Ant and Post images with appropriate decay correction. 24 hr total body retention (TBR) of I-123 were calculated and expressed in %, considering 100% at 4 hrs. Results: Demographic Profile of 3 Patient Groups. AST/ALT was < 35 and 24 hrs neck uptake was ≤ 1.0% all pts. Comparison of 24 hr % TBR of I-123 in 3 Patient Groups

  5. Preparation of [123I]- and [125I]epidepride: a dopamine D-2 receptor antagonist radioligand

    International Nuclear Information System (INIS)

    Clanton, J.A.; Schmidt, D.E.; Ansari, M.S.; Manning, R.G.; Kessler, R.M.; Paulis, T. de; Vanderbilt Univ., Nashville, TN; Baldwin, R.M.

    1991-01-01

    (S)-(-)-N-[(1-ethyl-2-pyrrolidinyl)methyl]-5-[ 123 I] iodo-2,3-dimethoxybenzamide (TDP 517) (proposed generic name, [ 123 I]epidepride) is the iodine-123 substituted analogue of isoremoxipride (FLB 457), both of which are very potent dopamine D-2 antagonists (epidepride K D 0.024 nM). [ 123 I] Epidepride was radioiodinated in 60-70% radiochemical yields in 35 min from the corresponding 5-(tributyltin) derivative using Na 123 I with a specific radioactivity of 3000 Ci/mmol, and oxidized in situ with chloramine-T. The aryltin precursor was prepared from non-labelled epidepride by palladium-catalyzed stannylation using bis(tri-n-butyltin) in triethylamine. Alternatively, using no carrier-added Na 125 I as the radioisotope, [ 125 I] epidepride at 2000 Ci/mmol specific radioactivity was prepared in 86% radiochemical yield and 99% radiochemical purity after purification by reverse phase HPLC in ethanolic phosphate buffer. (author)

  6. Diabetic retinopathy is associated with insulin resistance and cardiovascular autonomic dysfunction in type 2 diabetic patients

    International Nuclear Information System (INIS)

    Anan, Futoshi; Takayuki, Masaki; Takahashi, Naohiko; Nakagawa, Mikiko; Eshima, Nobuoki; Saikawa, Tetsunori; Yoshimatsu, Hironobu

    2009-01-01

    Diabetic retinopathy (DR) and cardiovascular autonomic dysfunction are associated with high mortality in type 2 diabetic patients. This preliminary study was therefore designed to test the hypothesis that DR is associated with insulin resistance and cardiovascular autonomic dysfunction in type 2 diabetic patients without insulin treatment. Seventy persons were diagnosed to have type 2 diabetes in the examination from June 2004 to May 2006. The study group consisted of 29 type 2 diabetic patients with DR (age: 58±6 years, mean±standard deviation (s.d.)) and 41 type 2 diabetic patients with no DR (NDR) (n=41, 58±5 years). Cardiovascular autonomic function was assessed by baroreflex sensitivity (BRS), heart rate variability, plasma norepinephrine concentration and cardiac 123 I-metaiodobenzylguanidine (MIBG) scintigraphic findings. DR patients had lower BRS, early and delayed 123 I-MIBG myocardial uptake values and higher percent washout rate (WR) of 123 I-MIBG than the NDR patients. With respect to metabolic findings, DR patients had higher fasting plasma insulin concentration (P 123 I-MIBG (P 123 I-MIBG are independently associated with DR in Japanese patients with type 2 diabetes mellitus. (author)

  7. Myocardial viability assessment with dynamic low-dose iodine-123-iodophenylpentadecanoic acid metabolic imaging: comparison with myocardial biopsy and reinjection SPECT thallium after myocardial infarction.

    Science.gov (United States)

    Murray, G L; Schad, N C; Magill, H L; Vander Zwaag, R

    1994-04-01

    Aggressive cardiac revascularization requires recognition of stunned and hibernating myocardium, and cost considerations may well govern the technique used. Dynamic low-dose (1 mCi) [123I]iodophenylpentadecanoic acid (IPPA) metabolic imaging is a potential alternative to PET using either 18FDG or 15O-water. Resting IPPA images were obtained from patients with severe ischemic cardiomyopathy, and transmural myocardial biopsies were obtained during coronary bypass surgery to confirm viability. Thirty-nine of 43 (91%) biopsies confirmed the results of the IPPA images with a sensitivity for viability of 33/36 (92%) and a specificity of 6/7 (86%). Postoperatively, wall motion improved in 80% of IPPA-viable, dysfunctional segments. Furthermore, when compared to reinjection thallium (SPECT-TI) scans after myocardial infarction, IPPA-SPECT-TI concordance occurred in 27/35 (77%) (K = 0.536, p = 0.0003). Similar to PET, IPPA demonstrated more viability than SPECT-TI, 26/35 (74%) versus 18/35 (51%) (p = 0.047). Metabolic IPPA cardiac viability imaging is a safe, inexpensive technique that may be a useful alternative to PET.

  8. Usefulness of 123I-Meta-iodobenzylguanidine (MIBG) myocardial scintigraphy for evaluation of cardiac sympathetic nervous system function in diabetic patients

    International Nuclear Information System (INIS)

    Tamura, Koji; Nakatani, Yuko; Doi, Kenji; Adachi, Gakuji; Takada, Kou; Onishi, Satoshi

    2001-01-01

    The cardiac sympathetic nervous system function of diabetic patients with no definite cardiovascular complications other than hypertension was evaluated by 123 I -MIBG myocardial scintigraphy. The subjects consisted of 82 diabetic patients, 59 men, 23 women, mean age 57 years, 17 with hypertension and 65 with normal blood pressure, and they were compared with normal controls (8 men and 3 women, mean age 54 years). Myocardial scintigraphy was performed 10 minutes and 4 hours after administration of MIBG. The superior mediastinum and whole myocardium were set as regions of interest, and the heart-to-mediastinum ratio (H/M ratio) and the washout rate (%WR) were calculated. The mean observation period was 18±12 months, and 17 of the 65 diabetic patients with normal blood pressure before the study developed hypertension during the observation period. There were significant differences in H/M ratio and %WR between the diabetic patients and normal controls (H/M ratio; 1.96±0.34 vs 2.27±0.20, %WR; 24.71±16.99% vs 12.89±11.94). The diabetic patients with hypertension had higher morbidity with diabetic retinopathy and a lower H/M ratio. The 17 patients who developed hypertension during the observation period showed an increase in %WR and a reduction in the H/M ratio. Five patients who died during the observation period had a reduced H/M ratio and increased of %WR. 123 I-MIBG myocardial scintigraphy in diabetic patients was shown to be useful for detecting cardiac sympathetic nervous system dysfunction, predicting the development of hypertension, and identifying patients who had a poor outcome. Diabetic patients with abnormal signals on MIBG myocardial scintigraphy need to be monitored much more carefully. (K.H.)

  9. Use of 6-[18F]-fluorodopamine positron emission tomography (PET) as first-line investigation for the diagnosis and localization of non-metastatic and metastatic phaeochromocytoma (PHEO).

    NARCIS (Netherlands)

    Timmers, H.J.L.M.; Eisenhofer, G.; Carrasquillo, J.A.; Chen, C.C.; Whatley, M.; Ling, A.; Adams, K.T.; Pacak, K.

    2009-01-01

    OBJECTIVE: Imaging modalities available for the localization of phaeochromocytoma (PHEO) include computed tomography (CT), magnetic resonance imaging (MRI), [(123)I]- or [(131)I]-labelled metaiodobenzylguanidine ((123/131)I-MIBG) scintigraphy and 6-[(18)F]-fluorodopamine ((18)F-FDA) positron

  10. Radionuclide study of thyroid function in pediatrics, using sup(99m)Tc, 123I or 131I: 150 case-reports

    International Nuclear Information System (INIS)

    Guillet, J.; Basse-Cathalinat, B.; Soubiran, G.; Blanquet, P.; Guillet, G.

    1981-01-01

    THe best radioisotope for in vivo thyroid investigations is the one which provides the highest quality scintigrams with the least radiation exposure. The choice of 131 I, 123 I or sup(99m)Tc in 150 children is discussed. Cases included 25 dysgenesis, 4 goiters with hypothyroidism, 56 goiters without thyroid dysfunction, 3 thyroiditis, and 11 cold nodules. When thyroid scanning is performed with 131 I, the gland's radiation exposure is high. 123 I is preferable since a fairly high activity can be obtained without delivering an excessive radiation dose. (approximately 2 rad to the thyroid for 50 microCi/m 2 ). sup(99m)Tc which is readily available is not a true iodine analog. It does not give a true picture of iodine metabolism. 123 I was generally used in cases of hypothyroidism, goiter (whenever a defect in thyroid hormone synthesis was suspected) and hyperthyroidism. sup(99m)Tc was generally used in other cases. The low radiation doses delivered by these radioisotopes allows study of thyroid function in the neonate [fr

  11. Myocardial uptake ratio of iodine-123 labeled beta-methyl iodophenylpentadecanoic acid ({sup 123}I-BMIPP) in relation to the concentration of the substrates of energy

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchimochi, Shinsaku; Tamaki, Nagara; Kawamoto, Masahide [Kyoto Univ. (Japan). Faculty of Medicine] [and others

    1995-06-01

    Iodine-123 beta-methyl iodophenylpentadecanoic acid (BMIPP) has been used for evaluating myocardial fatty acid metabolism in vivo. The whole body BMIPP imaging was acquired in 26 patients (11 with HCM, 11 with CAD and 4 with DCM) to calculate % uptake in the myocardium and to correlate its uptake with biochemical data, including blood sugar (BS), nonesterified fatty acid (NEFA) and insulin in the blood. BMIPP was administered at rest with overnight fasting state, and the anterior and posterior whole body imaging was performed one hour later. The background corrected whole myocardial counts were calculated to obtain %BMIPP uptake. In addition, the heart to mediastinum count ratio (H/M ratio) was calculated from the mean counts in the heart and the upper mediastinum in the anterior view. The %BMIPP uptake was 3.70{+-}1.22% and H/M ratio was 2.30{+-}0.23. The patients with DCM showed higher %BMIPP uptake value (DCM=5.58{+-}0.67% vs. CAD=3.09{+-}0.97% and HCM=3.63{+-}0.86%, both p<0.01), but similar values of H/M ratio with other patients (DCM=2.43{+-}0.20, CAD=2.22{+-}0.25 and HCM=2.32{+-}0.20). Although the biochemical data varied at the time of the tracer administration, they were not significantly correlated with the %BMIPP uptake or H/M ratio. However, there was a significant correlation between %BMIPP uptake and H/M ratio with the correlation coefficient of 0.80 (p<0.001). We conclude that the myocardial uptake of BMIPP is not influenced by the plasma substrate level under the fasting state. (author).

  12. Relation between thallium-201/iodine 123-BMIPP subtraction and fluorine 18 deoxyglucose polar maps in patients with hypertrophic cardiomyopathy.

    Science.gov (United States)

    Ito, Y; Hasegawa, S; Yamaguchi, H; Yoshioka, J; Uehara, T; Nishimura, T

    2000-01-01

    Clinical studies have shown discrepancies in the distribution of thallium-201 and iodine 123-beta-methyl-iodophenylpentadecanoic acid (BMIPP) in patients with hypertrophic cardiomyopathy (HCM). Myocardial uptake of fluorine 18 deoxyglucose (FDG) is increased in the hypertrophic area in HCM. We examined whether the distribution of a Tl-201/BMIPP subtraction polar map correlates with that of an FDG polar map. We normalized to maximum count each Tl-201 and BMIPP bull's-eye polar map of 6 volunteers and obtained a standard Tl-201/BMIPP subtraction polar map by subtracting a normalized BMIPP bull's-eye polar map from a normalized Tl-201 bull's-eye polar map. The Tl-201/BMIPP subtraction polar map was then applied to 8 patients with HCM (mean age 65+/-12 years) to evaluate the discrepancy between Tl-201 and BMIPP distribution. We compared the Tl-201/BMIPP subtraction polar map with an FDG polar map. In patients with HCM, the Tl-201/BMIPP subtraction polar map showed a focal uptake pattern in the hypertrophic area similar to that of the FDG polar map. By quantitative analysis, the severity score of the Tl-201/BMIPP subtraction polar map was significantly correlated with the percent dose uptake of the FDG polar map. These results suggest that this new quantitative method may be an alternative to FDG positron emission tomography for the routine evaluation of HCM.

  13. Iodine Deficiency

    Science.gov (United States)

    ... Fax/Phone Home » Iodine Deficiency Leer en Español Iodine Deficiency Iodine is an element that is needed ... world’s population remains at risk for iodine deficiency. Iodine Deficiency FAQs WHAT IS THE THYROID GLAND? The ...

  14. Defective organification of iodine in an infant demonstrated with 123J and gamma camera

    International Nuclear Information System (INIS)

    Goebel, R.; Leb, G.; Sulzer, M.; Graz Univ.

    1979-01-01

    A defective organification of iodine is demonstrated in a two year old male infant. The availability and a relatively simple radiation detector and storage system (gamma camera and 1600 word memory) gives a reasonable low radiation dose, allows correction for extrathyroid neck activity and obviates problems of collimation. (orig.) [de

  15. Novel iodinated tracers, MIBG and BMIPP, for nuclear cardiology.

    Science.gov (United States)

    Tamaki, Nagara; Yoshinaga, Keiichiro

    2011-02-01

    With the rapid growth of molecular biology, in vivo imaging of such molecular process (i.e., molecular imaging) has been well developed. The molecular imaging has been focused on justifying advanced treatments and for assessing the treatment effects. Most of molecular imaging has been developed using PET camera and suitable PET radiopharmaceuticals. However, this technique cannot be widely available and we need alternative approach. ¹²³I-labeled compounds have been also suitable for molecular imaging using single-photon computed tomography (SPECT) ¹²³I-labeled meta-iodobenzylguanidine (MIBG) has been used for assessing severity of heart failure and prognosis. In addition, it has a potential role to predict fatal arrhythmia, particularly for those who had and are planned to receive implantable cardioverter-defibrillator treatment. ¹²³I-beta-methyl-iodophenylpentadecanoic acid (BMIPP) plays an important role for identifying ischemia at rest, based on the unique capability to represent persistent metabolic alteration after recovery of ischemia, so called ischemic memory. Since BMIPP abnormalities may represent severe ischemia or jeopardized myocardium, it may permit risk analysis in CAD patients, particularly for those with chronic kidney disease and/or hemodialysis patients. This review will discuss about recent development of these important iodinated compounds.

  16. Usefulness of rCBF analysis in diagnosing Parkinson's disease. Supplemental role with MIBG myocardial scintigraphy

    International Nuclear Information System (INIS)

    Nagamachi, Shigeki; Wakamatsu, Hideyuki; Kiyohara, Shogo

    2008-01-01

    123 I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy is a useful tool for differentiating idiopathic Parkinson's disease (PD) from parkinsonism (PS) caused by other disorders. However, cardiac MIBG uptake is affected by various causes. Alternatively, hypoperfusion in the occipital lobe of PD is reported recently. The objective is to clarify the correlation between regional cerebral blood flow (rCBF) alteration and cardiac MIBG uptake in PD. In addition, we examined whether additional brain perfusion analysis improved the differential diagnostic ability for PD from PS when compared with MIBG scintigraphy alone. Forty-nine patients with PD (27 mild groups: Hoehn and Yahr stages I, II; 22 severe groups: Hoehn and Yahr stages III, IV) and 28 patients with PS participated. We compared absolute rCBF values between PD and PS. In addition, we determined correlation between MIBG parameters and each rCBF value. Finally, we compared the diagnostic ability for the differentiation of PD from PS between two diagnostic criteria, each MIBG index abnormality alone [heart-to-mediastinum ratio, H/M (E) 40%] and each MIBG index abnormality or occipital lobe hypoperfusion ( 123 I-MIBG myocardial imaging can be recommended. (author)

  17. No difference in urinary iodine concentrations between Boston-area breastfed and formula-fed infants.

    Science.gov (United States)

    Gordon, Joshua H; Leung, Angela M; Hale, Andrea R; Pearce, Elizabeth N; Braverman, Lewis E; He, Xuemei; Belfort, Mandy B; Nelson, Sara M; Brown, Rosalind S

    2014-08-01

    Thyroid hormone is essential for normal mental and physical development in infancy and childhood and is dependent on adequate iodine intake. During the first few months of life, infants are reliant on breastmilk and/or infant formula as their sole sources of dietary iodine. The iodine status of U.S. infants has not been well studied. This was a cross-sectional study of 95 breastfed and/or formula-fed infants less than 3 months of age in the Boston area. We measured iodine content from infants' single spot urine samples and assessed associations with infant feeding type as well as maternal demographic data, salt and multivitamin use, smoking status, and diet. The median infant urine iodine concentration was 197.5 μg/L (range 40-897.5 μg/L). Median infant urine iodine concentrations were similar between infants who were exclusively breastfed (n=39, 203.5 μg/L; range 61.5-395.5 μg/L), formula-fed (n=44, 182.5 μg/L; range 40-897.5 μg/L), and mixed (n=10, 197.8 μg/L; range 123-592.5) (p=0.88). There were no significant correlations of infant urinary iodine with maternal salt or multivitamin use (regularly or in the past 24 hours), active or secondhand cigarette smoke exposures, infant weight, infant length, or recent maternal ingestion of common iodine-containing foods, although the correlations with iodine-containing foods are difficult to accurately determine due to the small sample sizes of these variables. Both breastfed and formula-fed infants less than 3 months of age in the Boston area were generally iodine sufficient. Larger studies are needed to confirm these observations among infants nationwide and elucidate other factors that may contribute to infant iodine nutrition.

  18. Iodine 123-17-iodoheptadecanoic acid for metabolic liver studies in humans

    International Nuclear Information System (INIS)

    Hoeck, A.S.; Spohr, G.; Schmitz, M.; Notohamiprodjo, G.; Porschen, R.; Vyska, K.; Freundlieb, C.; Shreeve, W.W.; Feinendegen, L.E.

    1986-01-01

    (17- 123 I)-Iodoheptadecanoic acid ([ 123 I]HA) was used for dynamic planar scintigraphy of the liver in normal individuals (control I), in patients without liver disease but with elevated serum cholesterol and/or triglycerides (control II), and in patient groups with alcohol-induced fatty liver (PG I), fatty liver not due to alcohol (PG II), alcohol-induced liver cirrhosis (PG III), or liver cirrhosis of the posthepatitic type (PG IV). Tracer uptake and elimination time were assayed in different liver regions; mean elimination time was expressed for total liver. In control I, tracer uptake was homogeneous, and mean elimination time was 20.7 +/- 5.3 min without significant local variations. In control II, tracer uptake was reduced but homogeneous and mean elimination time was 59.4 +/- 35.8 min with some local variations. In PG I, uptake was reduced and inhomogeneous and elimination time was the same as in control I, irrespective of cholesterol and triglyceride values. In PG II, uptake was the same as in PG I but mean elimination time was 48 +/- 8.1 min with some local variations. In PG III, uptake was extremely reduced and spotty and elimination time correlated with the severity of disease from 19 to 881 min in different liver regions

  19. Iodine-123-labeled radiotracers for cardiovascular and testicular imaging studies: labeling of phenyl fatty acids for myocardial studies, fibronectin for thrombus localization, and human chorionic gonadotropin for testicular studies

    International Nuclear Information System (INIS)

    Kulkarni, P.V.; Lewis, S.E.; McConnell, J.; Buja, L.M.; Wilson, J.E. III; Willerson, J.T.; Parkey, R.W.

    1985-01-01

    Development and evaluation of iodine-123-labeled compounds for potential applications in certain imaging studies are described. A new method utilizing an organothallium intermediate has been developed to radioiodinate phenyl fatty acids. The method is simple, and consistently high yields (80 to 90%) can be obtained on a routine basis. The biodistribution patterns of the product prepared by this method were found to be very similar to those produced by the direct electrophilic substitution method. Radioiodinated fibronectin (FN) localized in experimental thrombi and pulmonary emboli. In dogs the deep-vein thrombi could be visualized within 3 hr of postinjection of the tracer. Radioiodinated human chorionic gonadotropin (HCG) localized in rat testes which permitted the scintigraphic visualization of scrotal as well as abdominal testes in rats. The localization appears to be receptor mediated

  20. Usefulness of {sup 123}I-Meta-iodobenzylguanidine (MIBG) myocardial scintigraphy for evaluation of cardiac sympathetic nervous system function in diabetic patients.

    Energy Technology Data Exchange (ETDEWEB)

    Tamura, Koji; Nakatani, Yuko; Doi, Kenji; Adachi, Gakuji; Takada, Kou

    2001-11-01

    The cardiac sympathetic nervous system function of diabetic patients with no definite cardiovascular complications other than hypertension was evaluated by {sup 123}I -MIBG myocardial scintigraphy. The subjects consisted of 82 diabetic patients, 59 men, 23 women, mean age 57 years, 17 with hypertension and 65 with normal blood pressure, and they were compared with normal controls (8 men and 3 women, mean age 54 years). Myocardial scintigraphy was performed 10 minutes and 4 hours after administration of MIBG. The superior mediastinum and whole myocardium were set as regions of interest, and the heart-to-mediastinum ratio (H/M ratio) and the washout rate (%WR) were calculated. The mean observation period was 18{+-}12 months, and 17 of the 65 diabetic patients with normal blood pressure before the study developed hypertension during the observation period. There were significant differences in H/M ratio and %WR between the diabetic patients and normal controls (H/M ratio; 1.96{+-}0.34 vs 2.27{+-}0.20, %WR; 24.71{+-}16.99% vs 12.89{+-}11.94). The diabetic patients with hypertension had higher morbidity with diabetic retinopathy and a lower H/M ratio. The 17 patients who developed hypertension during the observation period showed an increase in %WR and a reduction in the H/M ratio. Five patients who died during the observation period had a reduced H/M ratio and increased of %WR. {sup 123}I-MIBG myocardial scintigraphy in diabetic patients was shown to be useful for detecting cardiac sympathetic nervous system dysfunction, predicting the development of hypertension, and identifying patients who had a poor outcome. Diabetic patients with abnormal signals on MIBG myocardial scintigraphy need to be monitored much more carefully. (K.H.)

  1. Meta-iodobenzylguanidine inhibits complex I and III of the respiratory chain in the human cell line Molt-4

    NARCIS (Netherlands)

    Cornelissen, J.; Wanders, R. J.; van Gennip, A. H.; van den Bogert, C.; Voûte, P. A.; van Kuilenburg, A. B.

    1995-01-01

    In this paper we report the effects of meta-iodobenzylguanidine (MIBG), a structural analogue of norepinephrine, on cell proliferation and several parameters related to mitochondrial respiration in Molt-4 cells. In micromolar concentrations, MIBG completely inhibited the proliferation of Molt-4

  2. Effects of cross talk on dual energy SPECT imaging between 123I-BMIPP and 201Tl

    International Nuclear Information System (INIS)

    Morita, Masato; Narita, Hitoshi; Yamamoto, Juro; Fukutake, Naoshige; Ohyanagi, Mitsumasa; Iwasaki, Tadaaki; Fukuchi, Minoru

    1994-01-01

    The study was undertaken to determine how much cross talk influences the visual assessment of dual energy single photon emission computed tomographic (SPECT) images with iodine 123 beta-methyl-p-iodophenylpentadecanoic acid (I-123 BMIPP) and thallium-201 in 15 patients with acute myocardial infarction. After single SPECT with I-123 BMIPP was undertaken, simultaneous dual SPECT with I-123 BMIPP and Tl-201 were undertaken in all patients. Three patients also underwent single SPECT with Tl-201. I-123 BMIPP and Tl-201 uptake was graded in four-score for the comparison between single and dual SPECT images. There was good correlation between dual energy SPECT and both single I-123 BMIPP SPECT (pS=0.97) and single Tl-201 SPECT (pS=0.59). Uptake scores were increased on dual energy SPECT, compared with single I-123 SPECT (8 out of 132 segments) and single Tl-201 SPECT (12 out of 36 segments). Overall, there was a comparatively well correlation between single SEPCT with either I-123 BMIPP or Tl-201 and dual energy SPECT images. However, one tracer uptake sometimes increased in the other tracer defect areas. This was noticeable when I-123 BMIPP exerted an effect on Tl-201. (N.K.)

  3. Iodine volatility

    International Nuclear Information System (INIS)

    Beahm, E.C.; Shockley, W.E.

    1984-01-01

    The ultimate aim of this program is to couple experimental aqueous iodine volatilities to a fission product release model. Iodine partition coefficients, for inorganic iodine, have been measured during hydrolysis and radiolysis. The hydrolysis experiments have illustrated the importance of reaction time on iodine volatility. However, radiolysis effects can override hydrolysis in determining iodine volatility. In addition, silver metal in radiolysis samples can react to form silver iodide accompanied by a decrease in iodine volatility. Experimental data are now being coupled to an iodine transport and release model that was developed in the Federal Republic of Germany

  4. Iodogen-mediated radiolabeling of Bevacizumab with I-123 for clinical applications

    International Nuclear Information System (INIS)

    Lemps, R. de; Desruet, M.; Bacot, S.; Ahmadi, M.; Ghezzi, C.; Desruet, M.; Fagret, D.; Berger, F.

    2014-01-01

    Bevacizumab is a monoclonal antibody, directed against vascular endothelial growth factor (VEGF), and is currently used in various types of cancers (breast, lung, colorectal). In order to administer to humans glioblastomas, we developed its iodine 123 radiolabeling for in vitro and in vivo studies subsequent. The aim of the study is to choose the best radioiodination conditions based on feasibility in a hospital radiopharmacy: Quick one step method under mild condition, reproducible, using materials for pharmaceutical use and in a closed-system. Method Bevacizumab was radiolabeled with "1"2"3I using Iodogen, the most widely used oxidants in direct labelling techniques for tyrosyl residues-containing compounds. We have been explored two crucial parameters for clinical transfer: the amount of oxidant required (50μg and 100μg) and the choice of the purification column (size exclusion column or anion exchange resin), respectively. Quality control was performed before and after purification of each condition in order to evaluate the radiochemical purity (RCP) and purification efficiency. The stability of the radiolabeled molecule is evaluated over time and also when the solution is diluted with unlabeled bevacizumab. Moreover, the in vitro stability of "1"2"3I-bevacizumab was determined in presence of human blood at 15, 30, 60 and 120 min. Labeling yield before purification was 96.5% for the first condition (50μg Iodogen) and 95.5% for the second one (100μg Iodogen). The radiochemical purity was 99.5% after purification on a size exclusion column and 99% after purification on anion exchange resin. The purification yield with size exclusion column is 75%, compared with 81% of the anionic exchange resin. The stability in the labeling medium of "1"2"3I-bevacizumab at 3, 6, 24 and 30 h after labeling showed a RCP at 100%, 93%, 99.8% and 99.8% for condition 1 so that it was found to be 99.2%, 100%, 99.3%, 99.5% for condition 2, respectively. In vitro incubation with

  5. Radionuclide study of thyroid function in pediatrics, using sup(99m)Tc, /sup 123/I or /sup 131/I: 150 case-reports

    Energy Technology Data Exchange (ETDEWEB)

    Guillet, J.; Basse-Cathalinat, B.; Soubiran, G.; Blanquet, P. (Hopital Pellegrin, 33 - Bordeaux (France)); Guillet, G. (Johns Hopkins Medical Institutions, Baltimore, MD (USA). Div. of Nuclear Medicine)

    1981-11-01

    THe best radioisotope for in vivo thyroid investigations is the one which provides the highest quality scintigrams with the least radiation exposure. The choice of /sup 131/I, /sup 123/I or sup(99m)Tc in 150 children is discussed. Cases included 25 dysgenesis, 4 goiters with hypothyroidism, 56 goiters without thyroid dysfunction, 3 thyroiditis, and 11 cold nodules. When thyroid scanning is performed with /sup 131/I, the gland's radiation exposure is high. /sup 123/I is preferable since a fairly high activity can be obtained without delivering an excessive radiation dose. (approximately 2 rad to the thyroid for 50 microCi/m/sup 2/). sup(99m)Tc which is readily available is not a true iodine analog. It does not give a true picture of iodine metabolism. /sup 123/I was generally used in cases of hypothyroidism, goiter (whenever a defect in thyroid hormone synthesis was suspected) and hyperthyroidism. sup(99m)Tc was generally used in other cases. The low radiation doses delivered by these radioisotopes allows study of thyroid function in the neonate.

  6. Production of gaseous radiotracers CH3I and I2 through Na123I salt

    International Nuclear Information System (INIS)

    Candeiro, R.E.M.; Pereira, W.P.

    2011-01-01

    The objective of the present work was to develop, separately, methodology for production of two gaseous tracers through the sodium iodide NaI marked with 123 I. Found in the nature in form different, the iodine has been used in diverse works in the area of the industry and health. These two forms of the gaseous iodine, the methyl iodide, CH 3 I, and molecular iodine, I 2 , are very unstable and volatile in the ambient temperature and presents different problems in clean-up and monitoring systems. The syntheses were processed with sodium iodide (NaI) 1M aqueous solution marked with 1 23I . The production of gas I 2 was realized with in chlorine acid (HCl) and sodium iodate salt (NaIO 3 ) and the CH 3 I was used, the salt of NaI and the reagent (CH 3 ) 2 SO 4 . The production of gases was initially realized through in unit in glass with an inert material and the purpose was to study the kinetic of reaction and to determine the efficiency of production. The two synthesis occurs in the reaction bottle and after of produced, the gas is stored in the collect bottle that contains a starch solution for fixed the I 2 , and in syntheses of CH 3 I contains a silver nitrate solution for your fixation. To determine the efficiency of production of gases, analytic tests were realized, where the consumption of iodide ions of the bottle of reaction are measured. The optimization of production of the each gaseous tracer was studied varying parameter as: concentration of iodide, concentration of acid and temperature. After, the syntheses of the radiotracers were realized in the compact unit, having been used as main reagent the salt radiated of sodium iodide, Na 123 I. The transportation of elementary iodine and methyl iodine was studied by a scintillation detector NaI (2 x 2)' positioned in the reaction bottle. (author)

  7. Radionuclide Basics: Iodine

    Science.gov (United States)

    ... Centers Radiation Protection Contact Us Share Radionuclide Basics: Iodine Iodine (chemical symbol I) is a chemical element. ... in the environment Iodine sources Iodine and health Iodine in the Environment All 37 isotopes of iodine ...

  8. Clinical use of nuclear cardiology in the assessment of heart failure

    International Nuclear Information System (INIS)

    Han Lei; Shi Hongcheng

    2011-01-01

    Nuclear cardiology is the most commonly performed non-invasive cardiac imaging test in patients with heart failure, and it plays an important role in their assessment and management. Quantitative gated single positron emission computed tomography is used to assess quantitatively cardiac volume, left ventricular ejection fraction, stroke volume, and cardiac diastolic function. Resting and stress myocardial perfusion imaging can not only identify nonischemic heart failure and ischemic heart failure, but also demonstrate myocardial viability. Diastolic heart failure also termed as heart failure with a preserved left ventricular ejection fraction is readily identified by nuclear cardiology techniques and can accurately be estimated by peak filling rate and time to peak filling rate. With newer techniques such as three-dimensional, quantitative gated single positron emission computed tomography can assess movement of the left ventricle, and wall thickening evaluation aids its assessment. Myocardial perfusion imaging is also commonly used to identify candidates for implantable cardiac defibrillator and cardiac resynchronization therapies. Neurotransmitter imaging using 123 I-metaiodobenzylguanidine offers prognostic information in patients with heart failure. Metabolism and function in the heart are closely related, and energy substrate metabolism is a potential target of medical therapies to improve cardiac function in patients with heart failure. Cardiac metabolic imaging using 123 I-15-(p-iodophenyl) 3-R, S-methylpentadecacoic acid is a commonly used tracer in clinical studies to diagnose metabolic heart failure. Nuclear cardiology tests, including neurotransmitter imaging and metabolic imaging, are now easily preformed with new tracers to improve heart failure diagnosis. Nuclear cardiology techniques contribute significantly to identifying patients with heart failure and to guiding their management decisions. (authors)

  9. [{sup 123}I]-3-Iodcytisin as possible radiotracer for the imaging of nicotinic acetylcholine receptors using single photon emission computer tomography; [{sup 123}I]-3-Iodcytisin als moeglicher Radiotracer fuer die Darstellung der nikotinergen Acetylcholin Rezeptoren mittels Single-Photon-Emissions-Computertomographie

    Energy Technology Data Exchange (ETDEWEB)

    Paulik, Dagmar Julia

    2015-03-06

    For the synthesis of [{sup 123}I]-3-Iodcytisin as possible radiotracer for the imaging of nicotinic acetylcholine (nACh) receptors using SPECT two different technologies were used: the radio-iodination with iodogen and the radio-iodination with nitric acid. The latter one showed higher efficiency. The radiotracer will allow to detect degenerative processes and other nACh-depending diseases in the brain (Alzheimer, Parkinson) and to observe the progress. The autoradiography is aimed to the imaging of the nACh receptors in the brain bypassing the brain-blood barrier. The highest activity was measured in the thalamus of mice and rat brains.

  10. Sensitivity and related factors in iodine-123-β-methyl-p-iodophenyl-pentadecanoic acid myocardial scintigraphy to detect stable effort angina pectoris

    International Nuclear Information System (INIS)

    Tanaka, Tetsuya; Ohtsuki, Yumi; Takechi, Norikazu; Suzuki, Kenji; Nishibori, Yoshiharu; Matsuo, Akiko; Inoue, Keiji; Fujita, Hiroshi; Inoue, Naoto

    2005-01-01

    This study evaluated the sensitivity and the related factors in iodine-123-β-methyl-p-iodophenyl-pentadecanoic acid (BMIPP) scintigraphy to detect stable angina. The subjects were 198 patients with stable angina who underwent BMIPP before percutaneous coronary intervention or coronary bypass graft surgery. Patients with unstable angina, myocardial infarction, congestive heart failure, cardiomyopathy and vasospastic angina were excluded. After investigation of the sensitivity of BMIPP, the patients with single-vessel disease without collateral flow were classified into the normal 12 3 I-BMIPP uptake group (normal group) or decreased 123 I-BMIPP uptake group (decreased group), and various factors were compared between the two groups. Sensitivity was 61% overall, 58% in single-vessel disease, 69% in double-vessel disease, 53% in triple-vessel disease, 43% in only left main vessel disease, and 89% in left main and other vessel disease (NS). In single-vessel disease, the sensitivity was 40% in 75% coronary artery stenosis, 58% in 90% stenosis, 89% in 99% stenosis, and 69% in total occlusion (p=0.003). Comparing the decreased and normal groups, diabetes mellitus was more frequent in the normal group (14.6% vs 39.5%), minimal lumen diameter was smaller (0.75±0.37 vs 0.98±0.49 mm) and lesion length was longer in the decreased group (15.4±4.9 vs 11.6±5.5 mm). Logistic multivariate analysis showed that the independent factors were diabetes mellitus [odds ratio 0.20, 95% confidence interval (CI) 0.04-0.87, p=0.03], minimal lumen diameter (odds ratio 0.10, 95% CI 0.02-0.48, p=0.003) and lesion length (odds ratio 1.12, 95% CI 1.00-1.25, p=0.03). BMIPP is useful in stable angina patients because of the acceptable sensitivity. Diabetes mellitus, minimal lumen diameter and lesion length were independent factors associated with decreased BMIPP uptake. (author)

  11. Use of thallium-201 myocardial scintigraphy for the prediction of the response to {beta}-blocker therapy in patients with dilated cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Hara, Yuji; Hamada, Mareomi; Ohtsuka, Tomoaki; Ogimoto, Akiyoshi; Saeki, Hideyuki; Suzuki, Jun; Matsunaka, Tsuyoshi; Nakata, Shigeru; Shigematsu, Yuji [Ehime Univ., Shigenobu (Japan). School of Medicine

    2002-12-01

    This study was performed to evaluate whether thallium-201 myocardial scintigraphy (Tl-201) and iodine-123-metaiodobenzylguanidine (MIBG) myocardial scintigraphy could predit the usefulness of {beta}-blocker therapy in patients with dilated cardiomyopathy (DCM). Tl-201 and MIBG were performed in 47 patients before {beta}-blocker therapy. Patients were classified into group A, if their cardiac function improved, and group B, whose function remained unchanged Two types of extent score (ES) by Tl-201 were proposed to quantitate myocardial damage, mean-2SD (ES-2) and mean -3SD (ES-3). The ES difference between ES-2 and ES-3 was calculated, and according to ES and ES difference, DCM cases were classified into 3 groups: mild-defect type (mild-type), moderate-defect type (moderate-type) and severe-defect type (severe-type). The heart-to-mediastinum (H/M) MIBG uptake ratio was evaluated, and the percent washout ratio of myocardial MIBG was obtained from these data. Group A comprised 18 mild-type, 14 moderate-type and 1 severe-type cases, and group B comprised 5 mild-type, 4 moderate-type and 5 severe-type cases. A significant relation was observed between the defect type on Tl-201 and the response to {beta}-blocker therapy (p=0.0090). Both H/M MIBG uptake ratios and washout ratio were not significantly different in the 2 groups. Tl-201 may be useful for predicting the response to {beta}-blocker therapy in patients with DCM. (author)

  12. Is placental iodine content related to dietary iodine intake?

    LENUS (Irish Health Repository)

    Burns, R

    2011-08-01

    Delivery of iodine to the foetus depends not only on maternal dietary iodine intake but also on the presence of a functioning placental transport system. A role for the placenta as an iodine storage organ has been suggested, and this study compares the iodine content of placentas from women giving birth at term in Ireland and Iran, areas with median urinary iodine of 79 and 206 μg\\/l respectively.

  13. Single photon emission computed tomography with N-isopropyl-p-[123I] iodoamphetamine in dementia of the Alzheimer type

    International Nuclear Information System (INIS)

    Tsunoda, Masahiko; Fujii, Tsutomu; Tanii, Yasuyuki; Yasui, Shinichi; Yuasa, Satoru; Shimizu, Akinori; Kurachi, Masayoshi; Seki, Hiroyasu; Fukuta, Tsutomu.

    1989-01-01

    Correlation between brain uptake of N-isopropyl-p-[I-123]iodoamphetamine (I-123 IMP), as shown on single photon emission computed tomography (SPECT) scans, and clinical stages was examined in 8 patients with Alzheimer type dementia. The patients were clinically staged as Stage I (3), Stage II (3), or Stage III (2). The count ratio of each cerebral lobe to the cerebellum was calculated on horizontal SPECT scans. Stage I patients had a decreased I-123 IMP uptake in the temporal and parietal lobes. The decreased uptake in these areas became marked in Stage II patients, with diffusely slight uptake of I-123 IMP in the brain. In Stage III patients, the uptake of I-123 IMP was markedly decreased in the whole brain, including temporal, parietal, and frontal lobes. For five patients of Stage II and III, bilateral differences in the cerebral hemispheres were observed, corresponding to neurologic symptoms. Iodine-123 IMP SPECT was thus considered useful in clinically evaluating Alzheimer type dementia and in determining degenerative process of this disease. (Namekawa, K)

  14. A prospective evaluation of contrast and radiation dose and image quality in cardiac CT in children with complex congenital heart disease using low-concentration iodinated contrast agent and low tube voltage and current.

    Science.gov (United States)

    Hou, Qiao-Ru; Gao, Wei; Sun, Ai-Min; Wang, Qian; Qiu, Hai-Sheng; Wang, Fang; Hu, Li-Wei; Li, Jian-Ying; Zhong, Yu-Min

    2017-02-01

    To the assess image quality, contrast dose and radiation dose in cardiac CT in children with congenital heart disease (CHD) using low-concentration iodinated contrast agent and low tube voltage and current in comparison with standard dose protocol. 110 patients with CHD were randomized to 1 of the 2 scan protocols: Group A (n = 45) with 120 mA tube current and contrast agent of 270 mgI/ml in concentration (Visipaque ™ ; GE Healthcare Ireland, Co., Cork, UK); and Group B (n = 65) with the conventional 160 mA and 370 mgI/ml concentration contrast (Iopamiro ® ; Shanghai Bracco Sine Pharmaceutical Corp Ltd, Shanghai, China). Both groups used 80 kVp tube voltage and were reconstructed with 70% adaptive statistical iterative reconstruction algorithm. The CT value and noise in aortic arch were measured and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. A five-point scale was used to subjectively evaluate image quality. Contrast and radiation dose were recorded. There was no difference in age and weight between the two groups (all p > 0.05). The iodine load and radiation dose in Group A were statistically lower (3976 ± 747 mgI vs 5763 ± 1018 mgI in iodine load and 0.60 ± 0.08 mSv vs 0.77 ± 0.10 mSv in effective dose; p  0.05), and with good agreement between the two observers. Comparing the surgery results, the diagnostic accuracy for extracardiac and intracardiac defects for Group A was 96% and 92%, respectively, while the corresponding numbers for Group B were 95% and 93%. Compared with the standard dose protocol, the use of low tube voltage (80 kVp), low tube current (120 mA) and low-concentration iodinated contrast agent (270 mgI/ml) enables a reduction of 30% in iodine load and 22% in radiation dose while maintaining compatible image quality and diagnostic accuracy. Advances in knowledge: The new cardiac CT scanning protocol can largely reduce the adverse effects of

  15. Radiation of the thyroid during examination of patients with thyroid diseases using radioactive iodine

    Energy Technology Data Exchange (ETDEWEB)

    Zvonova, I.A.; Likhtarev, A.A.; Nikolaeva, A.A.

    1984-02-01

    Basing on 131I uptake functions in the thyroid of 109 patients irradiation doses of this organ were evaluated for persons with normal iodine metabolism and in the following diseases: hypothyrosis, moderate thyrotoxicosis, nodular toxic and nontoxic goiter, vegetative neurosis. Maximum tolerant doses of 123I, 125I, 131I and 132I are recommended for diagnostic examination of thyroid function and scanning of this organ.

  16. Effects of cross talk on dual energy SPECT imaging between [sup 123]I-BMIPP and [sup 201]Tl

    Energy Technology Data Exchange (ETDEWEB)

    Morita, Masato; Narita, Hitoshi; Yamamoto, Juro; Fukutake, Naoshige; Ohyanagi, Mitsumasa; Iwasaki, Tadaaki; Fukuchi, Minoru (Hyogo College of Medicine, Nishinomiya (Japan))

    1994-01-01

    The study was undertaken to determine how much cross talk influences the visual assessment of dual energy single photon emission computed tomographic (SPECT) images with iodine 123 beta-methyl-p-iodophenylpentadecanoic acid (I-123 BMIPP) and thallium-201 in 15 patients with acute myocardial infarction. After single SPECT with I-123 BMIPP was undertaken, simultaneous dual SPECT with I-123 BMIPP and Tl-201 were undertaken in all patients. Three patients also underwent single SPECT with Tl-201. I-123 BMIPP and Tl-201 uptake was graded in four-score for the comparison between single and dual SPECT images. There was good correlation between dual energy SPECT and both single I-123 BMIPP SPECT (pS=0.97) and single Tl-201 SPECT (pS=0.59). Uptake scores were increased on dual energy SPECT, compared with single I-123 SPECT (8 out of 132 segments) and single Tl-201 SPECT (12 out of 36 segments). Overall, there was a comparatively well correlation between single SEPCT with either I-123 BMIPP or Tl-201 and dual energy SPECT images. However, one tracer uptake sometimes increased in the other tracer defect areas. This was noticeable when I-123 BMIPP exerted an effect on Tl-201. (N.K.).

  17. ASCI 2010 contrast media guideline for cardiac imaging: a report of the Asian Society of Cardiovascular Imaging cardiac computed tomography and cardiac magnetic resonance imaging guideline working group

    Science.gov (United States)

    Kitagawa, Kakuya; Tsai, I-Chen; Chan, Carmen; Yu, Wei; Yong, Hwan Seok; Choi, Byoung Wook

    2010-01-01

    The use of contrast media for cardiac imaging becomes increasing as the widespread of cardiac CT and cardiac MR. A radiologist needs to carefully consider the indication and the injection protocol of contrast media to be used as well as the possibility of adverse effect. There are several guidelines for contrast media in western countries. However, these are focusing the adverse effect of contrast media. The Asian Society of Cardiovascular Imaging, the only society dedicated to cardiovascular imaging in Asia, formed a Working Group and created a guideline, which summarizes the integrated knowledge of contrast media for cardiac imaging. In cardiac imaging, coronary artery evaluation is feasible by non-contrast MR angiography, which can be an alternative examination in high risk patients for the use of iodine contrast media. Furthermore, the body habitus of Asian patients is usually smaller than that of their western counterparts. This necessitates modifications in the injection protocol and in the formula for calculation of estimated glomerular filtration rate. This guideline provided fundamental information for the use of contrast media for Asian patients in cardiac imaging. PMID:20931289

  18. Chemisorption of organic iodine compounds forming from fission isotopes of radioactive iodine

    International Nuclear Information System (INIS)

    Tot, G.; Galina, F.; Zel'd, E.

    1977-01-01

    Studied is ethyl iodine adsorption, labelled by iodine 131, on palladium black and on aluminium oxide activized by palladium. The desorption of adsorbed iodine in the temperature range of 20-600 deg C by the mass spectroscopy and thermal gravimetric methods was investigated. At the ethyl iodine and palladium interaction the bond between carbon and iodine in the ethyl iodine molecule breaks down and extracting iodine reacts with palladium, forming a stable compound at high temperatures. Desorption of adsorbed iodine is insignificant up to the temperatures of 250-300 deg C. Thus, sorbents, containing palladium, may be successfully applied for iodine absorption from the organic iodine compounds. These compounds spontaneously appear from the iodine fragment ratio isotopes during their interaction with some environmental organic impurities

  19. Altering iodine metabolism in the calf by feeding iodine-binding agents

    International Nuclear Information System (INIS)

    Miller, J.K.; Swanson, E.W.; Lyke, W.A.; Byrne, W.F.

    1975-01-01

    Effects of feeding cottonseed meal and anion-exchange resin on iodine absorption and excretion by calves were investigated. Each additional amount of resin fed from 0.3 to 3.5 g/kg body weight further increased fecal excretion from single oral iodine-131 and intravenous iodine-125 doses. By feeding 3 to 10 g cottonseed meal/kg body weight, excretion of oral iodine-131 given daily was increased 7 to 94 percent in feces and reduced as much as 35 percent in urine, but plasma iodine-131 was not changed. Introducing 1 g resin/kg body weight daily into the diet increased fecal iodine-131 excretion three to five times that with cottonseed meal alone and reduced both plasma and urinary iodine-131. The same amount of resin fed daily had similar effects on excretion of iodine-131 injected subcutaneously each day. Although iodine depletion by a highly efficient iodine binder (resin) in the gastrointestinal tract is probable, iodine binding by a natural feed constituent (cottonseed meal) was relatively inefficient. (U.S.)

  20. Altering iodine metabolism in the calf by feeding iodine-binding agents

    International Nuclear Information System (INIS)

    Miller, J.K.; Swanson, E.W.; Lyke, W.A.; Byrne, W.F.

    1975-01-01

    Effects of feeding cottonseed meal and anion-exchange resin on iodine absorption and excretion by calves were investigated. Each additional amount of resin fed from 0.3 to 3.5 g/kg body weight further increased fecal excretion from single oral iodine-131 and intravenous iodine-125 doses. By feeding 3 to 10 g cottonseed meal/kg body weight, excretion of oral iodine-131 given daily was increased 7 to 94 percent in feces and reduced as much as 35 percent in urine, but plasma iodine-131 was not changed. Introducing 1 g resin/kg body weight daily into the diet increased fecal iodine-131 excretion three to five times that with cottonseed meal alone and reduced both plasma and urinary iodine-131. The same amount of resin fed daily had similar effects on excretion of iodine-131 injected subcutaneously each day. Although iodine depletion by a highly efficient iodine binder (resin) in the gastrointestinal tract is probable, iodine binding by a natural feed constituent (cottonseed meal) was relatively inefficient. (auth)

  1. I-131 metaiodobenzylguanidine: diagnostic use in neuroblastoma patients in relapse

    International Nuclear Information System (INIS)

    Heyman, S.; Evans, A.E.; D'Angio, G.J.

    1988-01-01

    Metaiodobenzylguanidine (MIBG) has been used for the detection and treatment of neuroectodermal tumors, including neuroblastoma. We report our experience with 131 I-MIBG used diagnostically in neuroblastoma patients with relapse. Thirty-eight studies were performed in 26 patients. There were 24 children (range 3 months-14 years) and two adults. While the study was found to be both sensitive and specific for the presence of disease, there are instances of discordance. False-negative studies were found with a markedly anaplastic tumor and with two mature ganglioneuromas. A bone lesion was negative with 131 I-MIBG, but positive on bone scan. A biopsy confirmed the presence of neuroblastoma. Caution should be exercised when scanning pretreated patients, and perhaps with newly diagnosed patients as well

  2. Recovery of iodine as iodine-125 from biological materials prior to assay

    International Nuclear Information System (INIS)

    Jones, G.B.; Belling, G.B.; Buckley, R.A.

    1979-01-01

    In biological tissues iodine is usually present as iodoamino acids or iodoproteins. The organic material must be oxidised and the iodine converted into iodate prior to the final spectrophotometric determination. At parts per billion (10 9 ) levels, recoveries of added iodine are difficult to measure precisely as iodine can easily be lost from the sample and added inorganic iodine may not be recovered in the same proportions as the naturally occurring iodine. Iodine-125 provides a much more sensitive, specific and accurate means of testing the recovery of nanogram amounts of iodine from biological tissues and it can be incorporated into tissues in the naturally occurring compounds. Plants can be grown in a solution culture containing iodine-125 and animals can be injected with iodine-125 to provide tissues where naturally occurring iodine compounds are labelled with radioactive iodine. These tissues can be used to examine the recovery of iodine after oven drying, freeze drying, alkali ashing and acid digestion of the samples. Experimental details are given for spinach, tobacco, oats, cauliflower and thyroid. Results are given and discussed. (author)

  3. Quantitative iodine-123 IMP imaging of brain perfusion in schizophrenia

    International Nuclear Information System (INIS)

    Cohen, M.B.; Lake, R.R.; Graham, L.S.

    1989-01-01

    Decreased perfusion in the frontal lobes of patients with chronic schizophrenia has been reported by multiple observes using a variety of techniques. Other observers have been unable to confirm this finding using similar techniques. In this study quantitative single photon emission computed tomography brain imaging was performed using p,5n [ 123 I]IMP in five normal subjects and ten chronically medicated patients with schizophrenia. The acquisition data were preprocessed with an image dependent Metz filter and reconstructed using a ramp filtered back projection technique. The uptake in each of 50 regions of interest in each subject was normalized to the uptake in the cerebellum. There were no significant confirmed differences in the comparable ratios of normal subjects and patients with schizophrenia even at the p = 0.15 level. Hypofrontality was not observed

  4. [sup 131]I-metaiodobenzylguanidine therapy for malignant pheochromocytoma

    Energy Technology Data Exchange (ETDEWEB)

    Sakahara, Harumi; Saga, Tsuneo; Hosono, Makoto; Kobayashi, Hisataka; Konishi, Junji (Kyoto Univ. (Japan). Faculty of Medicine); Endo, Keigo

    1994-05-01

    [sup 131]I-metaiodobenzylguanidine (MIBG) therapy was given to five patients with malignant pheochromocytoma. The patients received 1-3 doses of 3.33-4.625 GBq (total dose: 3.7 to 10.73 GBq). Partial tumor regression was observed in two patients, the tumor was unchanged in two patients, and slow progression was noted in one patient. Marked improvement in clinical symptoms was achieved in four patients. The other patients had no symptoms before [sup 131]I-MIBG treatment, but the serum epinephrine and dopamine decreased. There were no severe untoward responses in four patients. However, one patient developed transient but severe orthostatic hypotension, hypertension, and hyperglycemia from 1 week to 1 month after [sup 131]I-MIBG administration. Although complete remission was not obtained, all the patients achieved some benefit from [sup 131]I-MIBG therapy. Thus, [sup 131]I-MIBG appears to be useful for the palliation of malignant pheochromocytoma. (author).

  5. Iodine leaflets in chapter D5 'Distribution of iodine pills'

    International Nuclear Information System (INIS)

    1981-01-01

    Jodine leaflet A will be distributed together with iodine pills in a nuclear disaster. Iodine leaflet B is suitable for informing the public in advance. Iodine leaflet C informs physicians in a scientific way on the benefits and risk of iodine pills. (orig./HP) [de

  6. Perchlorate, iodine supplements, iodized salt and breast milk iodine content

    Energy Technology Data Exchange (ETDEWEB)

    Kirk, Andrea B. [Department of Epidemiology, School of Public Health, University of North Texas Health Sciences Center, 3500 Camp Bowie Blvd., Fort Worth, TX 76107 (United States); Kroll, Martina; Dyke, Jason V.; Ohira, Shin-Ichi; Dias, Rukshan A.; Dasgupta, Purnendu K. [Department of Chemistry and Biochemistry, 700 Planetarium Place, University of Texas at Arlington, Arlington, TX 76019 (United States)

    2012-03-15

    This study was undertaken to determine if increasing maternal iodine intake through single dose tablets will decrease breast milk concentrations of the iodine-uptake inhibitor, perchlorate, through competitive inhibition. We also sought to determine if the timing of supplementation influences the fraction of iodine excreted in milk versus urine and to compare the effectiveness of iodized salt as a means of providing iodine to breastfed infants. Thirteen women who did not use supplements, seven of whom used iodized salt and six of whom used non-iodized salt, submitted four milk samples and a 24-h urine collection daily for three days. Women repeated the sampling protocol for three more days during which {approx} 150 {mu}g of iodine were taken in the evening and again for three days with morning supplementation. Samples were analyzed using isotope-dilution inductively-coupled plasma-mass spectrometry for iodine and isotope-dilution ion chromatography-tandem mass spectrometry for perchlorate. No statistically significant differences were observed in milk iodine or perchlorate concentrations during the two treatment periods. Estimated perchlorate intake was above the U.S. National Academy of Sciences suggested reference dose for most infants. Single daily dose iodine supplementation was not effective in decreasing milk perchlorate concentrations. Users of iodized salt had significantly higher iodine levels in milk than non-users. Iodized salt may be a more effective means of iodine supplementation than tablets. - Highlights: Black-Right-Pointing-Pointer Estimated infant exposures to perchlorate were, on a {mu}g/kg basis, {approx} 5 Multiplication-Sign higher than those of mothers. Black-Right-Pointing-Pointer Daily supplements are less effective than iodized salt in providing iodine to lactating women. Black-Right-Pointing-Pointer Low iodine and high perchlorate in milk may place infants at risk of iodine deficiency.

  7. A simple method for the preparation of 123I and 125I labeled iodobenzodiazepines

    International Nuclear Information System (INIS)

    McBride, B.J.; Baldwin, R.M.; Kerr, J.M.; Jiannlong Wu

    1991-01-01

    The tributyltin derivative of the benzodiazepine antagonist ethyl 7-iodo-5,6-dihydro-5-methyl-6-oxo-4H-imidazo[1,5-a][1,4]benzodiazepine-3-carboxylate (Ro 16-0154) was synthesized by a one-step Pd catalyzed reaction between bistributyltin and Ro 16-0154. Electrophilic iodination of the tributyltin compound with no-carrier-added 125 I and 123 I gave a 50-70% radiochemical yield of a greater than 98% radiochemically pure Ro 16-0154. The specific activity of [ 123 I]Ro 16-0154 and [ 125 I]Ro 16-0154 was 180,000 and 1700 Ci/mmol, respectively, but the effective specific activity was 6900 and 300 Ci/mmol due to the presence of benzodiazepine impurities which have similar receptor binding properties. (author)

  8. Iodine deficiency and iodine excess in Jiangsu Province, China

    NARCIS (Netherlands)

    Zhao, J.

    2001-01-01

    Keywords:
    iodine deficiency, iodine excess, endemic goiter, drinking water, iodine intake, thyroid function, thyroid size, iodized salt, iodized oil, IQ, physical development, hearing capacity, epidemiology, meta-analysis, IDD, randomized trial, intervention, USA, Bangladesh,

  9. The Success Rate of Initial {sup 131I} Ablation in Differentiated Thyroid Cancer: Comparison Between Less strict and Very Strict Low Iodine Diets

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Ik Dong; Kim, Sung Hoon; Seo, Ye Young; Oh, Jin Kyoung; O, Joo Hyun; Chung, Soo Kyo [The Catholic Univ. of Korea, Seoul (Korea, Republic of)

    2012-03-15

    To decrease the risk of recurrence or metastasis in differentiated thyroid cancer (DTC), selected patients receive radioactive iodine ablation of remnant thyroid tissue or tumor. A low iodine diet can enhance uptake of radioactive iodine. We compared the success rates of radioactive iodine ablation therapy in patients who followed two different low iodine diets (LIDs). The success rates of postsurgical radioactive iodine ablation in DTC patients receiving empiric doses of 150 mCi were retrospectively reviewed. First-time radioactive iodine ablation therapy was done in 71 patients following less strict LID. Less strict LID restricted seafood, iodized salt, egg yolk, dairy products, processed meat, instant prepared meals, and multivitamins. Very strict LID additionally restricted rice, freshwater fish, spinach, and soybean products. Radioactive iodine ablation therapy was considered successful when follow up {sup 123I} whole body scan was negative and stimulated serum thyroglobulin level was less than 2.0 ng/mL. The success rate of patients following less strict LID was 80.3% and for very strict LID 75.6%. There was no statistically significant difference in the success rates between the two LID groups (P=0.48). Very strict LID may not contribute to improving the success rate of initial radioactive iodine ablation therapy at the cost of great inconvenience to the patient.

  10. Fatty acids labelled with iodine 123 or 131 in. omega. position; myocardial evolution

    Energy Technology Data Exchange (ETDEWEB)

    Riche, F.; Vidal, M. (Grenoble-1 Univ., 38 (France)); Mathieu, J.P.; Busquet, G.; Comet, M. (Grenoble-1 Univ., 38 - La Tronche (France)); Coornaert, S.; Bardy, A. (CEA Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France). Office des Rayonnements Ionisants); Godart, J. (Grenoble-1 Univ., 38 (France). Inst. des Sciences Nucleaires)

    A simple and rapid method of labelling a number of saturated acetylenic and Z or E ethylenic acids has been developed. The fatty acids are labelled with /sup 123/I- or /sup 131/I- in the ..omega.. position by isotopic exchange labelled NaI in acetone. Myocardial metabolism was studied by injecting the labelled fatty acids into mice.

  11. Iodine in diet

    Science.gov (United States)

    Diet - iodine ... Many months of iodine deficiency in a person's diet may cause goiter or hypothyroidism . Without enough iodine, ... and older children. Getting enough iodine in the diet may prevent a form of physical and intellectual ...

  12. Prevention of Cardiac Implantable Electronic Device Infections: Single Operator Technique with Use of Povidone-Iodine, Double Gloving, Meticulous Aseptic/Antiseptic Measures and Antibiotic Prophylaxis.

    Science.gov (United States)

    Manolis, Antonis S; Melita, Helen

    2017-01-01

    Cardiac implantable electronic device (CIED) implantation is complicated by infection still at a worrisome rate of 2-5%. Since early on during device implantation procedures, we have adopted an infection-preventive technique which has hitherto resulted in effective prevention of infections. Herein we present our results of applying this technique by a single operator in a prospective series of 762 consecutive patients undergoing device implantation. A meticulous search for and treatment of active, occult, or smoldering infection was undertaken preoperatively. An aseptic/antiseptic technique was used for implantation of each device. Skin preparation is thorough with initial cleansing performed with alcohol followed by povidone-iodine 10% solution, which is also used in the wound and inside the pocket. In addition, we routinely use double gloving, and IV antibiotic prophylaxis 1 hour before and for 48 hours afterwards followed by oral antibiotic for 2-3 days after discharge. The skin is closed with absorbable sutures. The study includes 382 patients having a new pacemaker (n = 333) or battery change, system upgrade or lead revision (n = 49), and 380 patients having a new implantable cardioverter-defibrillator (ICD) (n = 296) or device replacement/upgrade/lead revision (n = 84). The pacemaker group, aged 70.2 ± 16.5 years, includes 18% VVI, 49% DDD, 29% VDD, and 4% cardiac resynchronization therapy (CRT) devices. The ICD group, aged 61.3 ± 13.0 years, with a mean ejection fraction of 36 ± 13%, includes 325 ICD and 55 CRT implants. Over 26.6 ± 33.4 months for the pacemaker group and 36.6 ± 38.3 months for the ICD group, infection occurred in one patient in each group (0.26%) having a device replacement. A consistent and strict approach of aseptic/antiseptic technique with the use of double gloving and povidone-iodine solution within the pocket plus a 4-day regimen of antibiotic prophylaxis minimizes infections in CIED implants. © 2016 Wiley Periodicals, Inc.

  13. Iodine and thyroid function

    Directory of Open Access Journals (Sweden)

    Hye Rim Chung

    2014-03-01

    Full Text Available Severe iodine deficiency causes hypothyroidism that results in impaired somatic growth and motor development in children. Mild and moderate iodine deficiencies cause multifocal autonomous growth of thyroid, which results in thyrotoxicosis. On the other hand, iodine excess is associated with the development of hypothyroidism and thyroid autoimmunity. In areas of iodine deficiency, a sudden increase in iodine intake is associated with transient hyperthyroidism. Recent studies demonstrated that long-term thyroid function of subjects who experienced both iodine deficiency and iodine excess during childhood tended to be abnormal despite optimization of their current iodine intake. Iodine status in the Korean Peninsula is very unique because people in the Republic of Korea have been shown to have predominantly excessive iodine levels, whereas the Democratic People's Republic of Korea is known to be an iodine-deficient area. Further research is warranted to verify the optimal ranges of iodine intake and to clarify the effects of iodine intake on thyroid disorders in the Korean Peninsula.

  14. Iodine Deficiency

    NARCIS (Netherlands)

    Zimmermann, M.B.

    2009-01-01

    Iodine deficiency has multiple adverse effects in humans, termed iodine deficiency disorders, due to inadequate thyroid hormone production. Globally, it is estimated that 2 billion individuals have an insufficient iodine intake, and South Asia and sub-Saharan Africa are particularly affected.

  15. The effects of iodine on intelligence in children: a meta-analysis of studies conducted in China.

    Science.gov (United States)

    Qian, Ming; Wang, Dong; Watkins, William E; Gebski, Val; Yan, Yu Qin; Li, Mu; Chen, Zu Pei

    2005-01-01

    This study quantifies the effects of iodine on the intellectual development of children using a systematic manual literature search of Chinese publications related to iodine deficiency disorders. The Chinese Medical Reference Database, Medline, and Cochrane library were searched electronically in Chinese and English. Inclusion criteria included: studies conducted in China, comparing children (Intelligent Quotient (IQ) was measured using Binet or Raven Scales. The iodine sufficient control groups were comparable socially, economically, and educationally with the study groups. Random effects models were used in the meta-analysis. Effect size was the standard deviation IQ point (SIQP), which is equivalent to 15 IQ. Thirty-seven reported studies, total 12,291 children, were analysed. The effect size was an increase of 0.83, 0.82, and 0.32 SIQP respectively, for the children living in IS communities compared with those living in ID areas with no iodine supplementation, with inadequate iodine supplementation, or children who had received iodine during their mothers' pregnancy and after birth. These equal to 12.45, 12.3, 4.8 IQ points. Compared with that of children whose mothers were persistently exposed to ID, the total effect size of the 21 entries was an increase of 0.58 SIQP (8.7 IQ points) in the group receiving iodine supplementation during pregnancy. Furthermore, there was an increase on 1.15 SIQP of Binet or 0.8 SIQP on Raven Scale (17.25 or 12 IQ points) for children born more than 3.5 years after iodine supplementation program was introduced. The level of iodine nutrition plays a crucial role in the intellectual development of children. The intelligence damage of children exposed to severe ID was profound, demonstrated by 12.45 IQ points loss and they recovered 8.7 IQ points with iodine supplementation or IS before and during pregnancy. Iodine supplementation before and during pregnancy to women living in severe ID areas could prevent their children from

  16. Cardiac abnormalities in diabetic patients with mutation in the mitochondrial tRNA {sup Leu(UUR)}Gene

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, Hiroshi [Hyogo Medical Center for Adults, Akashi (Japan); Shiotani, Hideyuki

    1999-11-01

    An A-to-G transition at position 3243 of the mitochondrial DNA is known to be a pathogenic factor for mitochondrial myopathy, encephalopathy, lactic acidosis and stroke-like episodes (MELAS), diabetes and cardiomyopathy. This mutation causes dysfunction of the central nervous system in MELAS. Because the heart, as well as the brain and nervous system, is highly dependent on the energy produced by mitochondrial oxidation, these tissues are more vulnerable to mitochondrial defects. Cardiac abnormalities were assessed in 10 diabetic patients associated with this mutation using echocardiography and {sup 123}I-metaiodobenzylguanidine (MIBG) scintigraphy, and compared with 19 diabetic patients without the mutation. Duration of diabetes, therapy, control of blood glucose and diabetic complications, such as diabetic retinopathy and nephropathy, were not different between the 2 groups. Diabetic patients with the mutation had a significantly thicker interventricular septum (16.8{+-}3.7 vs 11.0{+-}1.6 mm, p<0.001) than those without the mutation. Fractional shortening was lower in diabetic patients with the mutation than those without it (30.7{+-}7.0 vs 42.5{+-}6.6, p<0.001). MIBG uptake on the delayed MIBG image was significantly lower in diabetic patients with the mutation than in those without the mutation (mean value of the heart to mediastinum ratio: 1.6{+-}0.2 vs 2.0{+-}0.4, p>0.05). In conclusion, left ventricular hypertrophy with or without abnormal wall motion and severely reduced MIBG uptake may be characteristic in diabetic patients with a mutation in the mitochondrial tRNA {sup Leu(UUR)} gene. (author)

  17. Production of gaseous radiotracers CH{sub 3}I and I{sub 2} through Na{sup 123}I salt

    Energy Technology Data Exchange (ETDEWEB)

    Candeiro, R.E.M., E-mail: ricardocandeiro@cnen.gov.b [Comissao Nacional de Energia Nuclear (DIFOR/CNEN-CE), Fortaleza, CE (Brazil). Distrito de Fortaleza; Brandao, L.B. [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Pereira, W.P. [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil)

    2011-07-01

    The objective of the present work was to develop, separately, methodology for production of two gaseous tracers through the sodium iodide NaI marked with {sup 123}I. Found in the nature in form different, the iodine has been used in diverse works in the area of the industry and health. These two forms of the gaseous iodine, the methyl iodide, CH{sub 3}I, and molecular iodine, I{sub 2}, are very unstable and volatile in the ambient temperature and presents different problems in clean-up and monitoring systems. The syntheses were processed with sodium iodide (NaI) 1M aqueous solution marked with 1{sup 23I}. The production of gas I{sub 2} was realized with in chlorine acid (HCl) and sodium iodate salt (NaIO{sub 3}) and the CH{sub 3}I was used, the salt of NaI and the reagent (CH{sub 3}){sub 2}SO{sub 4}. The production of gases was initially realized through in unit in glass with an inert material and the purpose was to study the kinetic of reaction and to determine the efficiency of production. The two synthesis occurs in the reaction bottle and after of produced, the gas is stored in the collect bottle that contains a starch solution for fixed the I{sub 2}, and in syntheses of CH{sub 3}I contains a silver nitrate solution for your fixation. To determine the efficiency of production of gases, analytic tests were realized, where the consumption of iodide ions of the bottle of reaction are measured. The optimization of production of the each gaseous tracer was studied varying parameter as: concentration of iodide, concentration of acid and temperature. After, the syntheses of the radiotracers were realized in the compact unit, having been used as main reagent the salt radiated of sodium iodide, Na{sup 123}I. The transportation of elementary iodine and methyl iodine was studied by a scintillation detector NaI (2 x 2)' positioned in the reaction bottle. (author)

  18. Experimental study on iodine chemistry (EXSI) - Containment experiments with elemental iodine

    Energy Technology Data Exchange (ETDEWEB)

    Kaerkelae, T.; Auvinen, A. (VTT Technical Research Centre of Finland (Finland)); Holm, J.; Ekberg, C. (Chalmers Univ. of Technology (Sweden)); Glaenneskog, H. (Vattenfall Power Consultant (Sweden))

    2009-10-15

    The behaviour of iodine during a severe accident has been studied in several experimental programs, ranging from the large-scale PHEBUS FP tests and intermediate-scale ThAI tests to numerous separate effect studies. Oxidation of iodine in gas phase has been one of the greatest remaining uncertainties in iodine behaviour during a severe accident. In this study the possible formation of iodine oxide aerosol due to radiolytic oxidation of gaseous iodine is experimentally tested and the reaction products are analysed. The experimental facility applied in this study is based on the sampling system built at VTT for ISTP program project CHIP conducted IRSN. The experimental facility and the measuring technology are sophisticated and unique in the area of nuclear research as well as in the field of aerosol science. The results from the experiments show an extensive particle formation when ozone and gaseous iodine react with each other. The formed particles were collected on filters, while gaseous iodine was trapped into bubbles. The particles were iodine oxides and the size of particles was approximately 100 nm. The transport of gaseous iodine through the facility decreased when both gaseous iodine and ozone were fed together into facility. Experimental study on radiolytic oxidation of iodine was conducted in co-operation between VTT and Chalmers University of Technology as a part of the NKS-R programs. (author)

  19. Experimental study on iodine chemistry (EXSI) - Containment experiments with elemental iodine

    International Nuclear Information System (INIS)

    Kaerkelae, T.; Auvinen, A.; Holm, J.; Ekberg, C.; Glaenneskog, H.

    2009-10-01

    The behaviour of iodine during a severe accident has been studied in several experimental programs, ranging from the large-scale PHEBUS FP tests and intermediate-scale ThAI tests to numerous separate effect studies. Oxidation of iodine in gas phase has been one of the greatest remaining uncertainties in iodine behaviour during a severe accident. In this study the possible formation of iodine oxide aerosol due to radiolytic oxidation of gaseous iodine is experimentally tested and the reaction products are analysed. The experimental facility applied in this study is based on the sampling system built at VTT for ISTP program project CHIP conducted IRSN. The experimental facility and the measuring technology are sophisticated and unique in the area of nuclear research as well as in the field of aerosol science. The results from the experiments show an extensive particle formation when ozone and gaseous iodine react with each other. The formed particles were collected on filters, while gaseous iodine was trapped into bubbles. The particles were iodine oxides and the size of particles was approximately 100 nm. The transport of gaseous iodine through the facility decreased when both gaseous iodine and ozone were fed together into facility. Experimental study on radiolytic oxidation of iodine was conducted in co-operation between VTT and Chalmers University of Technology as a part of the NKS-R programs. (author)

  20. Assessment of biodistribution of 131-IPPA in cardiac and non-cardiac tissues in laboratory animals by imaging

    International Nuclear Information System (INIS)

    Moradkani, S.; Sadadi, F.; Matloubi, M.; Jalilian, A. R.; Shafaie, K.; Karimian, A. R.; Daneshvari, S.

    2007-01-01

    The main substrate of myocardial metabolism is fatty acids which constitutes the principal agent for myocardial consumption and provides almost 60-80% of the energy utilized by the heart in the resting state. Evaluation of cardiac metabolism is important for the assessment of some of cardiac disorders such as Ischemic Heart disease (IHD), cardiomyopathy (functional disorders) and Hypertensive cardiac disorders. Today, almost in all of the developed countries, PET is the first step for diagnosis and assessment of cardiac metabolic disorders. It is, however, too expensive to be used in all centers and are not available in all countries. In this regards, 123-IPPA was introduced as a substitute of PET system for evaluation of cardiac function (metabolism) and it is a complementary method for other Para-clinical methods. We decided to have a preliminary study on IPPA and due to the lack of 123-I, we had to use 131-I. The labeling of IPPA by 131-I, purification and sterilization of 131-1PPA done by the Chemistry Group of Cyclotron Ward and the bio-kinetic and imaging of rat, mice (Laboratory Animals) were performed in the Nuclear Medicine Group. After injection of a proper dose of this radiotracer, the imaging was performed in an appropriate time. In our first images, there were intensive accumulation of tracer in animals' thyroid glands, though after the intake of Lugol solution, the thyroid did not appear and we had a number of excellent images of animal heart that was the target organ

  1. Clinical results with beta-methyl-p-(123I)iodophenylpentadecanoic acid, single-photon emission computed tomography in cardiac disease.

    Science.gov (United States)

    Nishimura, T; Uehara, T; Shimonagata, T; Nagata, S; Haze, K

    1994-01-01

    This study was undertaken to evaluate the relationships, between myocardial perfusion and metabolism. Simultaneous beta-methyl-p(123I)iodophenylpentadecanoic acid (123I-BMIPP) and thallium 201 myocardial single-photon emission computed tomography (SPECT) were performed in 25 patients with myocardial infarction (group A) and 16 patients with hypertrophic cardiomyopathy (group B). The severity scores of 123I-BMIPP and 201Tl myocardial SPECT images were evaluated semiquantitatively by segmental analysis. In Group A, dissociations between thallium- and 123I-BMIPP-imaged defects were frequently observed in patients with successful reperfusion compared with those with no reperfusion and those with reinfarction. In four patients with successful reperfusion, repeated 123I-BMIPP and 201Tl myocardial SPECT showed gradual improvement of the 123I-BMIPP severity score compared with the thallium severity score. In group B, dissociations between thallium- and 123I-BMIPP-imaged defects were also demonstrated in hypertrophic myocardium. In addition, nonhypertrophic myocardium also had decreased 123I-BMIPP uptake. In groups A and B, 123I-BMIPP severity scores correlated well with left ventricular function compared with thallium severity scores. These findings indicate that 123I-BMIPP is a suitable agent for the assessment of functional integrity, because left ventricular wall motion is energy dependent and 123I-BMIPP may reflect an aspect of myocardial energy production. This agent may be useful for the early detection and patient management of various heart diseases as an alternative to positron emission tomographic study.

  2. In vivo assessment of cardiac insulin resistance by nuclear probes using an iodinated tracer of glucose transport

    Energy Technology Data Exchange (ETDEWEB)

    Briat, Arnaud; Slimani, Lotfi; Perret, Pascale; Villemain, Daniele; Fagret, Daniel; Ghezzi, Catherine [INSERM, E0340, Radiopharmaceutiques Biocliniques, Grenoble (France); Univ Grenoble, Grenoble (France); Halimi, Serge [Univ Grenoble, Grenoble (France); Hopital Michallon, Service de Diabetologie, CHRU Grenoble, Grenoble (France); Demongeot, Jacques [Univ Grenoble, Grenoble (France); CNRS, UMR 5525, Grenoble (France)

    2007-11-15

    Insulin resistance, implying depressed cellular sensitivity to insulin, is a risk factor for type 2 diabetes and cardiovascular disease. This study is the first step towards the development of a technique of insulin resistance measurement in humans with a new tracer of glucose transport, [{sup 123}I]6-deoxy-6-iodo-D-glucose (6DIG). We investigated 6DIG kinetics in anaesthetised control rats and in three models of insulin-resistant rats: fructose fed, Zucker and ZDF. The study of myocardial 6DIG activity was performed under two conditions: first, 6DIG was injected under the baseline condition and then it was injected after a bolus injection of insulin. After each injection, radioactivity was measured over 45 min by external detection via NaI probes, in the heart and blood. A tri-compartment model was developed to obtain fractional transfer coefficients of 6DIG from the blood to the heart. These coefficients were significantly increased with insulin in control rats and did not change significantly in insulin-resistant rats. The ratio of the coefficient obtained under insulin to that obtained under basal conditions gave an index of cardiac insulin resistance for each animal. The mean values of these ratios were significantly lower in insulin-resistant than in control rats: 1.16 {+-} 0.06 vs 2.28 {+-} 0.18 (p < 0.001) for the fructose-fed group, 0.92 {+-} 0.05 vs 1.62 {+-} 0.25 (p < 0.01) for the Zucker group and 1.34 {+-} 0.06 vs 2.01 {+-} 0.26 (p < 0.05) for the ZDF group. These results show that 6DIG could be a useful tracer to image cardiac insulin resistance. (orig.)

  3. Iodine intake in Ireland

    International Nuclear Information System (INIS)

    Smith, P.P.A.; Hetherton, A.M.; O'Carroll, D.; Smith, D.F.; O'Halloran, M.J.; O'Donovan, D.K.

    1988-01-01

    A study of urinary iodine excretion and thyroid gland uptake of radioactive iodine 131 I was undertaken in the Dublin area with a view to providing data on the current iodine status in Ireland. A mean urinary iodine excretion of 118±82μg/gram creatinine (Median 96) obtained from 821 subjects attending general hospital outpatient clinics in the Dublin area in 1987, while excluding severe iodine deficiency in this particular cohort, obscured the fact that 250 (30%) had iodine excretion values ≤70 μ/g creatinine, a value approximating to the minimum daily iodine requirement. The results provide sufficient evidence of sporadic iodine deficiency to justify a more widespread study of the iodine status of the Irish population with a view to making recommendations on the possible need for iodine prophylaxis

  4. Iodination of phenol

    International Nuclear Information System (INIS)

    Christiansen, J.V.; Feldthus, A.; Carlsen, L.

    1990-01-01

    Phenol is iodinated in aqueous solution at pH 5 (acetate buffer) by elemental iodine or, if the iodine is present as iodide, enzymatically controlled by peroxidases. Generally mono-, di- and triiodophenols are obtained, the overall product composition being virtually identical for the two iodination modes. However, there is a tendency to a higher para to ortho ratio for the enzymatically controlled reaction. The mutual ratios of the single iodophenols depends on the initial concentration ratio between phenol and the iodinating species. The first step in the iodination leads preferentially to substitution in the ortho position rather than in the para position in contract to e.g. the corresponding bromination. The relative rates of the competive reactions in the combined iodination scheme has been derived. (author) 2 tabs., 3 ills., 15 refs

  5. A simple method for the quantification of benzodiazepine receptors using iodine-123 iomazenil and single-photon emission tomography

    International Nuclear Information System (INIS)

    Ito, Hiroshi; Goto, Ryoui; Koyama, Masamichi; Kawashima, Ryuta; Ono, Shuichi; Sato, Kazunori; Fukuda, Hiroshi

    1996-01-01

    Iodine-123 iomazenil (Iomazenil) is a ligand for central type benzodiazepine receptors that is suitable for single-photon emission tomography (SPET). The purpose of this study was to develop a simple method for the quantification of its binding potential (BP). The method is based on a two-compartment model (K 1 , influx rate constant; k 2 ', efflux rate constant; V T '(=K 1 /k 2 '), the total distribution volumes relative to the total arterial tracer concentration), and requires two SPET scans and one blood sampling. For a given input function, the radioactivity ratio of the early to delayed scans can be considered to tabulate as a function of k 2 ', and a table lookup procedure provides the corresponding k 2 ' value, from which K 1 and V t ' values are then calculated. The arterial input function is obtained by calibration of the standard input function by the single blood sampling. SPET studies were performed on 14 patients with cerebrovascular diseases, dementia or brain tumours (mean age ±SD, 56.0±12.2). None of the patients had any heart, renal or liver disease. A dynamic SPET scan was performed following intravenous bolus injection of Iomazenil. A static SPET scan was performed at 180 min after injection. Frequent blood sampling from the brachial artery was performed on all subjects for determination of the arterial input function. Two-compartment model analysis was validated for calculation of the V T ' value of Iomazenil. Good correlations were observed between V T ' values calculated by three-compartment model analysis and those calculated by the present method, in which the scan time combinations (early scan/delayed scan) used were 15/180 min, 30/180 min or 45/180 min (all combinations: r=0.92), supporting the validity of this method. The present method is simple and applicable for clinical use. (orig.)

  6. Efficacy of iodine-123-15-(p-iodophenyl)-3-R,S-methylpentadecanoic acid single photon emission computed tomography imaging in detecting myocardial ischemia in children with Kawasaki disease

    International Nuclear Information System (INIS)

    Hoshina, Masaru; Shiraishi, Hirohiko; Igarashi, Hiroshi; Kikuchi, Yutaka; Ichihashi, Kou; Momoi, Mariko Y.

    2003-01-01

    To evaluate its efficacy in detecting myocardial ischemia in children, iodine-123-labeled 15-(p-iodophenyl)-3-R,S-methylpentadecanoic acid (BMIPP) myocardial single photon emission computed tomography (SPECT) imaging was performed in 16 pediatric patients with Kawasaki disease (KD, 11 male, 5 female; mean age and range: 13 years 8 months and 8 years 11 months to 17 years 7 months). Five children with chest pain and no cardiac disease were studied as controls (2 male, 3 female; mean age and range: 13 years 4 months and 9 years 4 months to 17 years 11 months). Selective coronary angiography was also performed in the 16 patients to evaluate the location of coronary stenosis and coronary aneurysms. The SPECT images were expressed as polar maps (Bull's eye maps) and the 'defect' area was defined as where the uptake of BMIPP was less than the standardized BMIPP images of the 5 control children. In the 16 patients, 33 segments had coronary aneurysms and 10 (10/33: 30.3%) had significant coronary stenosis on selective coronary angiography. Nine of the 10 (90%) segments with significant coronary stenosis showed a defect on the BMIPP image whereas only 6 of the 23 (26.1%) segments without coronary stenosis showed a defect on BMIPP imaging. The sensitivity of BMIPP SPECT imaging for detection of coronary stenosis was 90% (9/10) and its specificity was 73.9% (17/23), whereas the sensitivity of 201 Tl SPECT imaging was 80% (8/10) and its specificity was 60% (14/23). There was no significant difference between the BMIPP and 201 Tl SPECT images in either the sensitivity or specificity for the detection of coronary stenosis. In the present series, only one case had discordant BMIPP uptake (BMIPP uptake 201 Tl uptake) in which there was a large coronary aneurysm and re-canalization after complete obstruction at segment 1 of the right coronary artery. This discordant BMIPP uptake reflects the possibility of ischemic but viable myocardium after re-canalization of a large aneurysm in

  7. 123I-Mibg scintigraphy and 18F-Fdg-Pet imaging for diagnosing neuroblastoma

    Science.gov (United States)

    Bleeker, Gitta; Tytgat, Godelieve Am; Adam, Judit A; Caron, Huib N; Kremer, Leontien Cm; Hooft, Lotty; van Dalen, Elvira C

    2015-01-01

    Background Neuroblastoma is an embryonic tumour of childhood that originates in the neural crest. It is the second most common extracranial malignant solid tumour of childhood. Neuroblastoma cells have the unique capacity to accumulate Iodine-123-metaiodobenzylguanidine (123I-MIBG), which can be used for imaging the tumour. Moreover, 123I-MIBG scintigraphy is not only important for the diagnosis of neuroblastoma, but also for staging and localization of skeletal lesions. If these are present, MIBG follow-up scans are used to assess the patient's response to therapy. However, the sensitivity and specificity of 123I-MIBG scintigraphy to detect neuroblastoma varies according to the literature. Prognosis, treatment and response to therapy of patients with neuroblastoma are currently based on extension scoring of 123I-MIBG scans. Due to its clinical use and importance, it is necessary to determine the exact diagnostic accuracy of 123I-MIBG scintigraphy. In case the tumour is not MIBG avid, fluorine-18-fluorodeoxy-glucose (18F-FDG) positron emission tomography (PET) is often used and the diagnostic accuracy of this test should also be assessed. Objectives Primary objectives: 1.1 To determine the diagnostic accuracy of 123I-MIBG (single photon emission computed tomography (SPECT), with or without computed tomography (CT)) scintigraphy for detecting a neuroblastoma and its metastases at first diagnosis or at recurrence in children from 0 to 18 years old. 1.2 To determine the diagnostic accuracy of negative 123I-MIBG scintigraphy in combination with 18F-FDG-PET(-CT) imaging for detecting a neuroblastoma and its metastases at first diagnosis or at recurrence in children from 0 to 18 years old, i.e. an add-on test. Secondary objectives: 2.1 To determine the diagnostic accuracy of 18F-FDG-PET(-CT) imaging for detecting a neuroblastoma and its metastases at first diagnosis or at recurrence in children from 0 to 18 years old. 2.2 To compare the diagnostic accuracy of 123I

  8. Relationship between the mismatch of 123I-BMIPP and 201Tl myocardial single-photon emission computed tomography and autonomic nervous system activity in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Yamanaka, Hiroyuki; Suzuki, Takeshi; Kishida, Hiroshi; Nagasawa, Koichi; Takano, Teruo

    2006-01-01

    The purpose of this study was to elucidate the relationship between the mismatch of thallium-201 (Tl) and iodine-123-beta-methyl-iodophenyl-pentadecanoic acid (BMIPP) myocardial single-photon emission computed tomography (SPECT) and autonomic nervous system activity in myocardial infarction (MI) patients. The subjects were 40 patients (34 males, 6 females) who underwent examinations by 123 I-BMIPP and 201 Tl myocardial SPECT imaging and 24-hour Holter monitoring within a 3-day period 3 weeks after the onset of their first MI. R-R intervals were analyzed every hour over a period of 24 hours by fast Fourier transformation (FFT). High frequency (HF) and low frequency (LF) were defined as markers of cardiac vagal activity in the former and the LF/HF ratio as sympathetic activity. Greater or more extensive decreases in the BMIPP image than that in the Tl image were defined as a positive mismatch. Patients were divided into positive and negative mismatch groups of 20 patients each. There were no significant differences between the 2 groups in age, sex, site of infarction, max CK (creatine kinase), max CK-MB, or left ventricular ejection fraction. The incidences of clinical signs suggesting residual myocardial ischemia were significantly greater in the positive than in the negative mismatch group (P 123 I-BMIPP and 201 Tl myocardial SPECT 3 weeks after a first acute myocardial infarction with uncomplicated moderate or severe heart failure and decreased heart rate variability are related to residual myocardial ischemia. A combined assessment of heart rate variability in 24 hour Holter electrocardiogram (ECG) monitoring and perfusion-metabolism mismatch in 123 I-BMIPP and 201 Tl myocardial SPECT is useful for determining residual myocardial ischemia in the follow-up of those with acute myocardial infarction. (author)

  9. Iodine and Pregnancy

    OpenAIRE

    Yarrington, Christina; Pearce, Elizabeth N.

    2011-01-01

    Iodine is a necessary element for the production of thyroid hormone. We will review the impact of dietary iodine status on thyroid function in pregnancy. We will discuss iodine metabolism, homeostasis, and nutritional recommendations for pregnancy. We will also discuss the possible effects of environmental contaminants on iodine utilization in pregnant women.

  10. Cardiac sympathetic nervous system imaging with (123)I-meta-iodobenzylguanidine: Perspectives from Japan and Europe

    NARCIS (Netherlands)

    Nakajima, K.; Scholte, A.; Nakata, T.; Dimitriu-Leen, A.C.; Chikamori, T.; Vitola, J.V.; Yoshinaga, K.

    2017-01-01

    Cardiac sympathetic nervous system dysfunction is closely associated with risk of serious cardiac events in patients with heart failure (HF), including HF progression, pump-failure death, and sudden cardiac death by lethal ventricular arrhythmia. For cardiac sympathetic nervous system imaging,

  11. Iodine

    Science.gov (United States)

    ... Health Information Supplement Fact Sheets Frequently Asked Questions Making Decisions What you Need To Know About Supplements Dietary ... mild iodine deficiency and of iodine supplements on cognitive ... breasts. It mainly affects women of reproductive age but can also occur ...

  12. A comparison of targeting of neuroblastoma with mIBG and anti L1-CAM antibody mAb chCE7: therapeutic efficacy in a neuroblastoma xenograft model and imaging of neuroblastoma patients

    NARCIS (Netherlands)

    Hoefnagel, C. A.; Rutgers, M.; Buitenhuis, C. K.; Smets, L. A.; de Kraker, J.; Meli, M.; Carrel, F.; Amstutz, H.; Schubiger, P. A.; Novak-Hofer, I.

    2001-01-01

    Iodine-131 labelled anti L1-CAM antibody mAb chCE7 was compared with the effective neuroblastoma-seeking agent 131I-labelled metaiodobenzylguanidine (MIBG) with regard to (a) its therapeutic efficacy in treating nude mice with neuroblastoma xenografts and (b) its tumour targeting ability in

  13. Low-level seaweed supplementation improves iodine status in iodine-insufficient women.

    Science.gov (United States)

    Combet, Emilie; Ma, Zheng Feei; Cousins, Frances; Thompson, Brett; Lean, Michael E J

    2014-09-14

    Iodine insufficiency is now a prominent issue in the UK and other European countries due to low intakes of dairy products and seafood (especially where iodine fortification is not in place). In the present study, we tested a commercially available encapsulated edible seaweed (Napiers Hebridean Seagreens® Ascophyllum nodosum species) for its acceptability to consumers and iodine bioavailability and investigated the impact of a 2-week daily seaweed supplementation on iodine concentrations and thyroid function. Healthy non-pregnant women of childbearing age, self-reporting low dairy product and seafood consumption, with no history of thyroid or gastrointestinal disease were recruited. Seaweed iodine (712 μg, in 1 g seaweed) was modestly bioavailable at 33 (interquartile range (IQR) 28-46) % of the ingested iodine dose compared with 59 (IQR 46-74) % of iodine from the KI supplement (n 22). After supplement ingestion (2 weeks, 0·5 g seaweed daily, n 42), urinary iodine excretion increased from 78 (IQR 39-114) to 140 (IQR 103-195) μg/l (Pseaweed was palatable and acceptable to consumers as a whole food or as a food ingredient and effective as a source of iodine in an iodine-insufficient population. In conclusion, seaweed inclusion in staple foods would serve as an alternative to fortification of salt or other foods with KI.

  14. A Spectroscopic Method for Determining Free Iodine in Iodinated Fatty-Acid Esters

    Science.gov (United States)

    Klyubin, V. V.; Klyubina, K. A.; Makovetskaya, K. N.

    2018-01-01

    It is shown that the concentration of free iodine in samples of iodinated fatty-acid esters can be measured using the electronic absorption spectra of their solutions in ethanol. The method proposed is rather simple in use and highly sensitive, allowing detection of presence of less than 10 ppm of free iodine in iodinated compounds. It is shown using the example of Lipiodol that this makes it possible to easily detect small amounts of free iodine in samples containing bound iodine in concentrations down to 40 wt %.

  15. Myocardial imaging with a radioiodinated norepinephrine storage analog

    International Nuclear Information System (INIS)

    Wieland, D.M.; Brown, L.E.; Rogers, W.L.; Worthington, K.C.; Wu, J.L.; Clinthorne, N.H.; Otto, C.A.; Swanson, D.P.; Beierwaltes, W.H.

    1981-01-01

    Meta-iodobenzylguanidine (M-IBG), an iodinated aromatic analog of the hypotensive drug guanethidine, localizes in the heart of the rat, dog, and rhesus monkey. A comparative study of tissue distribution in the dog has been performed with five myocardiophilic agents: thallium-201, I-125 16-iodohexadecanoic acid, H-3 norepinephrine, C-14 guanethidine and I-125 M-IBG. The last two compounds give heart concentrations and heart-to-blood concentration ratios similar to those of thallium-201. Planar and tomographic images of the hearts of the dog and rhesus monkey were obtained using I-131 or I-123 labeled M-IBG. Blocking studies with reserpine suggest that a major component of myocardial retention of M-IBG is sequestration within the norepinephrine storage vesicles of the adrenergic nerves. The localization of M-IBG in other organs with rich sympathetic innervation and the relative insensitivity of myocardial uptake to a wide range of loading doses lend additional support for a neuronal mode of retention

  16. Radioiodinated phenylalkyl malonic acid derivatives as pH-sensitive SPECT tracers.

    Directory of Open Access Journals (Sweden)

    Matthias Bauwens

    Full Text Available INTRODUCTION: In vivo pH imaging has been a field of interest for molecular imaging for many years. This is especially important for determining tumor acidity, an important driving force of tumor invasion and metastasis formation, but also in the process of apoptosis. METHODS: 2-(4-[(123I]iodophenethyl-2-methylmalonic acid (IPMM, 2-(4-[(123I]iodophenethyl-malonic acid (IPM, 2-(4-[(123I]iodobenzyl-malonic acid (IBMM and 4-[(123I]iodophthalic acid (IP were radiolabeled via the Cu(+ isotopic nucleophilic exchange method. All tracers were tested in vitro in buffer systems to assess pH driven cell uptake. In vivo biodistribution of [(123I]IPMM and [(123I]IPM was determined in healthy mice and the pH targeting efficacy in vivo of [(123I]IPM was evaluated in an anti-Fas monoclonal antibody (mAb apoptosis model. In addition a mouse RIF-1 tumor model was explored in which tumor pH was decreased from 7.0 to 6.5 by means of induction of hyperglycemia in combination with administration of meta-iodobenzylguanidine. RESULTS: Radiosynthesis resulted in 15-20% for iodo-bromo exchange and 50-60% yield for iodo-iodo exchange while in vitro experiments showed a pH-sensitive uptake for all tracers. Shelf-life stability and in vivo stability was excellent for all tracers. [(123I]IPMM and [(123I]IPM showed a moderately fast predominantly biliary clearance while a high retention was observed in blood. The biodistribution profile of [(123I]IPM was found to be most favorable in view of pH-specific imaging. [(123I]IPM showed a clear pH-related uptake pattern in the RIF-1 tumor model. CONCLUSION: Iodine-123 labeled malonic acid derivates such as [(123I]IPM show a clearly pH dependent uptake in tumor cells both in vitro and in vivo which allows to visualize regional acidosis. However, these compounds are not suitable for detection of apoptosis due to a poor acidosis effect.

  17. 123I and 13I purification for biomolecules labelling

    International Nuclear Information System (INIS)

    Catanoso, Marcela Forli

    2011-01-01

    The 123 I and 131 I are iodine radioisotopes widely used in Nuclear Medicine. The radioisotope 123 I is used in diagnosis through the SPECT technique and is routinely produced at IPEN in cyclotron through the reaction: '1 24 Xe (p, 2n) '1 23 Cs -> 123 Xe -> 123 I. The radioisotope 131 I is used both in diagnosis and therapy due to its physical characteristics of decay by β - and its γ-ray emissions that are softened with the use of specific collimators for diagnosis. It is routinely produced at IPEN using the nuclear reactor through the indirect reaction: 130 Te (n, γ) -> 131 Te -> 131 I, irradiating compounds containing Te. The radiopharmaceuticals prepared with these radioisotopes go through rigorous quality control tests and the chemical purity of the primary radioisotopes 123 I and 131 I are within the permissible limits currently defined. However, the presence of some chemical contaminants can prejudice the biomolecules labeling (monoclonal antibodies and peptides), that will produce radiopharmaceuticals of first generation to the oncology area. The aim of this work was to obtain a new purification method of these radioisotopes, allowing the labeling of biomolecules and also to established a process control on those radioisotopes. The methodology was separated on 3 steps: Evaluation of '1 23 I e 131 I radionuclidic purity using a hyper pure germanium detector, chemical purity using ICP-OES and the retention and elution study of 131 I in several absorbers to choose the most appropriate for the purification tests analyzing the behavior of the possible contaminants. The radionuclidic analyses showed the presence of Te and Co on 131 I samples and Te, Tc e Co on 123 I samples. The chemical purity analyses showed the presence of Al and Mo in 123 I, coming from the window material of the target holder and the presence of Al and Te in 131 I samples, coming from the target holder and the target, respectively. The retention and elution study selected the most

  18. Synthesis and biodistribution of 2-[123I]iodomelatonin in normal mice

    International Nuclear Information System (INIS)

    Al-Jammaz, I.; Al-Otaibi, B.; Aboul-Enein, H.; Amartey, J.K.

    2006-01-01

    Melatonin demands that this hormone and its receptors be well understood. With this aim in mind, synthetic melatonin was radioiodinated with no-carrier-added (n.c.a.) sodium iodide-123 using in situ generated peracetic acid as oxidizing agent for electrophilic iodination at room temperature. The radiochemical yield was typically greater than 80% after 20 min reaction time especially when relatively small amounts of activities were used (10 mCi). Biological evaluation was performed in normal mice. The distribution of the tracer did not reveal any specificity during the time frame studied. There was no significant retention in the whole brain

  19. Relationship between quantitative cardiac neuronal imaging with ¹²³I-meta-iodobenzylguanidine and hospitalization in patients with heart failure.

    Science.gov (United States)

    Parker, Matthew W; Sood, Nitesh; Ahlberg, Alan W; Jacobson, Arnold F; Heller, Gary V; Lundbye, Justin B

    2014-09-01

    Hospitalization in patients with systolic heart failure is associated with morbidity, mortality, and cost. Myocardial sympathetic innervation, imaged by (123)I-meta-iodobenzylguanidine ((123)I-mIBG), has been associated with cardiac events in a recent multicenter study. The present analysis explored the relationship between (123)I-mIBG imaging findings and hospitalization. Source documents from the ADMIRE-HF trial were reviewed to identify hospitalization events in patients with systolic heart failure following cardiac neuronal imaging using (123)I-mIBG. Time to hospitalization was analyzed with the Kaplan-Meier method and compared to the mIBG heart-to-mediastinum (H/M) ratio using multiple-failure Cox regression. During 1.4 years of median follow-up, 362 end-point hospitalizations occurred in 207 of 961 subjects, 79 % of whom had H/M ratio heart failure diagnosis, a low mIBG H/M ratio was associated with cardiac-related hospitalization (HR 1.48, 95 % CI 1.05 - 2.0; p = 0.02). The mIBG H/M ratio may risk-stratify patients with heart failure for cardiac-related hospitalization, especially when used in conjunction with BNP. Further studies are warranted to examine these relationships.

  20. [Assessment of dietary iodine intake of population in non-high-iodine areas in China].

    Science.gov (United States)

    Song, Xiaoyu; Li, Fengqin; Liu, Zhaoping; He, Yuna; Sui, Haixia; Mao, Weifeng; Liu, Sana; Yan, Weixing; Li, Ning; Chen, Junshi

    2011-03-01

    To assess the potential risk of dietary iodine insufficiency of population in non-high-iodine areas (water iodine China. The dietary iodine intake of 13 age-sex population groups were estimated by combining the data of iodine intake from food, table salt and drinking water. Two conditions were considered: consuming iodized salt or non-iodized salt. The data of food and table salt consumption were derived from the Chinese National Nutrition and Health Survey in 2002. Water consumption was calculated as the recommended water intake. Iodine contents of food, table salt and water were calculated from China Food Composition Table and iodine surveillance data. Under the condition of consuming iodized salt, the average iodine intake of all population groups was higher than the Recommended Nutrient Intake (RNI), while the iodine intakes of individuals above Upper Limits (UL) and below RNI were 5.8% and 13.4% respectively, and the iodine intake of individuals lower than the Estimated Average Requirement (EAR) was 9.4% in adults above 18 years of age (including pregnant and lactating women). If non-iodized salt was consumed, the average iodine intake of most sex-age population groups was higher than RNI, but the iodine intake of 97.6% of individuals would be lower than RNI, while the iodine intake of 97.4% of adults would be lower than EAR. The contribution of iodine from table salt was much higher than that from drinking water and food in the condition of consuming iodized salt, while food was the predominant contributor of dietary iodine in the condition of consuming non-iodized salt. The health risk of iodine deficiency was higher than that of iodine excess in areas where water iodine was China, and the risk of iodine insufficiency was much higher if non-iodized salt was consumed. Iodized salt should be the main sources of dietary iodine intake for population in areas where water iodine was China.

  1. The iodine reactivity

    International Nuclear Information System (INIS)

    2003-01-01

    The iodine is an important element because it has long life isotopes (such as iodine 129) and a great mobility in natural media. Iodine presents a complex chemistry because of its volatility and its strong redox reactivity. The S.E.C.R. works to better understand the reactivity of this element in different natural, industrial or biological environments. It plays a part in thermochemical sites as a possible way of hydrogen formation. This seminar gives some aspects relative to the chemical reactivity of iodine, since its thermochemistry in the I/S cycles to produce hydrogen to its reactivity in the natural medium and its potential radiological impact. This document includes 4 presentations transparencies) dealing with: the 129 I cycle rejected in the low radioactive gaseous and liquid effluents of the La Hague reprocessing plant (C. Frechou); a bibliographic review of iodine retention in soils (F. Bazer-Bachi); the hydrogen production and the iodine/sulfur thermochemical cycle (role of iodine in the process); and the direct characterization by electro-spray ionization mass spectroscopy of iodine fixation by fulvic acids (P. Reiller, B. Amekraz, C. Moulin, V. Moulin)

  2. Recovered neuronal viability revealed by Iodine-123-iomazenil SPECT following traumatic brain injury

    OpenAIRE

    Koizumi, Hiroyasu; Fujisawa, Hirosuke; Kurokawa, Tetsu; Suehiro, Eiichi; Iwanaga, Hideyuki; Nakagawara, Jyoji; Suzuki, Michiyasu

    2010-01-01

    We evaluated cortical damages following traumatic brain injury (TBI) in the acute phase with [123I] iomazenil (IMZ) single photon emission computed tomography (SPECT). In all, 12 patients with cerebral contusion following TBI were recruited. All patients underwent IMZ SPECT within 1 week after TBI. To investigate the changes in distribution of IMZ in the cortex in the chronic phase, after conventional treatment, patients underwent IMZ SPECT again. A decrease in the accumulation of radioligand...

  3. In vivo assessment of cardiac insulin resistance by nuclear probes using an iodinated tracer of glucose transport

    International Nuclear Information System (INIS)

    Briat, Arnaud; Slimani, Lotfi; Perret, Pascale; Villemain, Daniele; Fagret, Daniel; Ghezzi, Catherine; Halimi, Serge; Demongeot, Jacques

    2007-01-01

    Insulin resistance, implying depressed cellular sensitivity to insulin, is a risk factor for type 2 diabetes and cardiovascular disease. This study is the first step towards the development of a technique of insulin resistance measurement in humans with a new tracer of glucose transport, [ 123 I]6-deoxy-6-iodo-D-glucose (6DIG). We investigated 6DIG kinetics in anaesthetised control rats and in three models of insulin-resistant rats: fructose fed, Zucker and ZDF. The study of myocardial 6DIG activity was performed under two conditions: first, 6DIG was injected under the baseline condition and then it was injected after a bolus injection of insulin. After each injection, radioactivity was measured over 45 min by external detection via NaI probes, in the heart and blood. A tri-compartment model was developed to obtain fractional transfer coefficients of 6DIG from the blood to the heart. These coefficients were significantly increased with insulin in control rats and did not change significantly in insulin-resistant rats. The ratio of the coefficient obtained under insulin to that obtained under basal conditions gave an index of cardiac insulin resistance for each animal. The mean values of these ratios were significantly lower in insulin-resistant than in control rats: 1.16 ± 0.06 vs 2.28 ± 0.18 (p < 0.001) for the fructose-fed group, 0.92 ± 0.05 vs 1.62 ± 0.25 (p < 0.01) for the Zucker group and 1.34 ± 0.06 vs 2.01 ± 0.26 (p < 0.05) for the ZDF group. These results show that 6DIG could be a useful tracer to image cardiac insulin resistance. (orig.)

  4. Dicarbonic acid anilides containing radioactive iodine (iodine 131, 123, 125, or 132) as well as their metal and amine salts; methods for the preparation of these compounds and of radioactive functional diagnostics containing them

    International Nuclear Information System (INIS)

    Buttermann, G.

    1976-01-01

    A method for the preparation of dicarbonic acid anilides containing radioactive iodine is described. The initial substances are N,N dimethyl-p-toluene sulfonamide, N,N bis-dimethyl aminosulfon, or dimethyl sulfon, or mixtures of these, which are heated in aqueous solution or in a melt with an alkali or alkaline earth radioiodide as carrier-free as possible. From the water-soluble salts of the obtained iodine-labelled dicarbonic acid anilides aqueous solutions are produced with 1 mg up to 5 g iodine-labelled dicarbonic acid anilide per 10 ml and an activity of 0.025 and 25 mCi per ml with physiologically compatible bases as radioactive functional diagnostics. (RB) [de

  5. Diagnosis of Alzheimer's disease and multiple infarct dementia by tomographic imaging of iodine-123 IMP

    International Nuclear Information System (INIS)

    Cohen, M.B.; Graham, L.S.; Lake, R.

    1986-01-01

    Tomographic imaging of the brain was performed using a rotating slant hole collimator and [ 123 I]N-isopropyl p-iodoamphetamine (IMP) in normal subjects (n = 6) and patients with either Alzheimer's disease (n = 5) or multiple infarct dementia (n = 3). Four blinded observers were asked to make a diagnosis from the images. Normal subjects and patients with multiple infarct dementia were correctly identified. Alzheimer's disease was diagnosed in three of the five patients with this disease. One patient with early Alzheimer's disease was classified as normal by two of the four observers. Another patient with Alzheimer's disease had an asymmetric distribution of IMP and was incorrectly diagnosed as multiple infarct dementia by all four observers. Limited angle tomography of the cerebral distribution of 123 I appears to be a useful technique for the evaluation of demented patients

  6. Iodine intake in Denmark

    International Nuclear Information System (INIS)

    Pedersen, K.M.; Noehr, S.B.; Laurberg, P.

    1997-01-01

    Iodine deficiency with a high frequency of goitre and, in severely affected areas, cretinism is common in some areas of the world. In Denmark the iodine intake as evaluated by urinary iodine excretion has been at a stable low level for many years, except for the part of the population now taking iodine supplementation as part of vitamin/mineral preparations. The iodine intake is lowest in the western part to the country where an epidemiological study of elderly subjects has demonstrated a high frequency of goitre and hyperthyroidism in women. This supports the suggestion of a controlled moderate increase in iodine intake via an iodine supplementation program. (au) 40 refs

  7. Iodine-123 labelled N-(2-fluoroethyl)-2β-carbomethoxy-3β-(4-iodophenyl)nortropane for dopamine transporter imaging in the living human brain

    International Nuclear Information System (INIS)

    Kuikka, J.T.; AAkerman, K.; Bergstroem, K.A.; Karhu, J.; Hiltunen, J.; Haukka, J.; Heikkinen, J.; Tiihonen, J.; Wang, S.; Neumeyer, J.L.

    1995-01-01

    Here we report a pilot comparison of [ 123 I]β-CIT and [ 123 I]β-CIT-FP with a new tropane derivative, [ 123 I]N-(2-fluoroethyl)-2β-carbomethoxy-3β-(4-iodophenyl)nortropane ([ 123 I]β-CIT-FE), using SPET imaging in four healthy male subjects. Peak uptake of [ 123 I]β-CIT-FE into the basal ganglia occurred very rapidly (0.5 h after injection of tracer), after which the striatal washout obeyed a bi-exponential form. The specific DAT binding of [ 123 I]β-CIT-FE into the basal ganglia was somewhat less (0.785±0.117) than that of [ 123 I]β-CIT (0.922±0.004) or [ 123 I]β-CIT-FP (0.813±0.047). All these tracers have excellent imaging quality in healthy control subjects. However, the relatively fast washout of [ 123 I]β-CIT-FE and low temporal resolution of older SPET cameras may limit the use of this tracer to the measurement of the DAT density. (orig./UG)

  8. Iodine-123 labelled N-(2-fluoroethyl)-2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)nortropane for dopamine transporter imaging in the living human brain

    Energy Technology Data Exchange (ETDEWEB)

    Kuikka, J.T. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); AAkerman, K. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); Bergstroem, K.A. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); Karhu, J. [Dept. of Clinical Neurophysiology, Kuopio Univ. Hospital (Finland); Hiltunen, J. [MAP Medical Technologies Oy, Tikkakoski (Finland); Haukka, J. [MAP Medical Technologies Oy, Tikkakoski (Finland); Heikkinen, J. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); Tiihonen, J. [Dept. of Forensic Psychiatry, Niuvanniemi Hospital, Kuopio (Finland); Wang, S. [Research Biochemical International (RBI), Natick, MA (United States); Neumeyer, J.L. [Research Biochemical International (RBI), Natick, MA (United States)

    1995-07-01

    Here we report a pilot comparison of [{sup 123}I]{beta}-CIT and [{sup 123}I]{beta}-CIT-FP with a new tropane derivative, [{sup 123}I]N-(2-fluoroethyl)-2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)nortropane ([{sup 123}I]{beta}-CIT-FE), using SPET imaging in four healthy male subjects. Peak uptake of [{sup 123}I]{beta}-CIT-FE into the basal ganglia occurred very rapidly (0.5 h after injection of tracer), after which the striatal washout obeyed a bi-exponential form. The specific DAT binding of [{sup 123}I]{beta}-CIT-FE into the basal ganglia was somewhat less (0.785{+-}0.117) than that of [{sup 123}I]{beta}-CIT (0.922{+-}0.004) or [{sup 123}I]{beta}-CIT-FP (0.813{+-}0.047). All these tracers have excellent imaging quality in healthy control subjects. However, the relatively fast washout of [{sup 123}I]{beta}-CIT-FE and low temporal resolution of older SPET cameras may limit the use of this tracer to the measurement of the DAT density. (orig./UG)

  9. SPECT imaging with the serotonin transporter radiotracer [123I]p ZIENT in nonhuman primate brain

    International Nuclear Information System (INIS)

    Cosgrove, Kelly P.; Staley, Julie K.; Baldwin, Ronald M.; Bois, Frederic; Plisson, Christophe; Al-Tikriti, Mohammed S.; Seibyl, John P.; Goodman, Mark M.; Tamagnan, Gilles D.

    2010-01-01

    Introduction: Serotonin dysfunction has been linked to a variety of psychiatric diseases; however, an adequate SPECT radioligand to probe the serotonin transporter system has not been successfully developed. The purpose of this study was to characterize and determine the in vivo selectivity of iodine-123-labeled 2β-carbomethoxy-3β-(4'-((Z)-2-iodoethenyl)phenyl)nortropane, [ 123 I]p ZIENT, in nonhuman primate brain. Methods: Two ovariohysterectomized female baboons participated in nine studies (one bolus and eight bolus to constant infusion at a ratio of 9.0 h) to evaluate [ 123 I]p ZIENT. To evaluate the selectivity of [ 123 I]p ZIENT, the serotonin transporter blockers fenfluramine (1.5, 2.5 mg/kg) and citalopram (5 mg/kg), the dopamine transporter blocker methylphenidate (0.5 mg/kg) and the norepinephrine transporter blocker nisoxetine (1 mg/kg) were given at 8 h post-radiotracer injection. Results: In the bolus to constant infusion studies, equilibrium was established by 4-8 h. [ 123 I]p ZIENT was 93% and 90% protein bound in the two baboons and there was no detection of lipophilic radiolabeled metabolites entering the brain. In the high-density serotonin transporter regions (diencephalon and brainstem), fenfluramine and citalopram resulted in 35-71% and 129-151% displacement, respectively, whereas methylphenidate and nisoxetine did not produce significant changes ( 123 I]p ZIENT is a favorable compound for in vivo SPECT imaging of serotonin transporters with negligible binding to norepinephrine and dopamine transporters.

  10. Iodinated bleomycin

    International Nuclear Information System (INIS)

    Lunghi, F.; Riva, P.; Assone, F.; Villa, M.; Plassic, G.

    1978-01-01

    Bleomycin was labelled with iodine-131 by the iodine monochloride method. Iodination did not alter the chemical and chromatographic features and ''in vitro'' stability studies on freeze-dried 131 I-Bleomycin having a specific activity of 1 mCi/mg, stored at different temperatures, showed no appreciable variation of the free-iodine content. Tissue distribution of 131 I-Bleomycin has been evaluated in tumor bearing rats. Patients have been injected with 0.5-1.0 mCi of 131 I-Bleomycin corresponding to a maximum of 1.5 mg. No adverse reactions have been observed. Total body scans have been performed at 2, 6, 24 and 48 hours after injection. The iodinated Bleomycin was rapidly distributed and cleared from the body and showed an early uptake in the neoplastic tissue. A diagnostic accuracy of 90% has been observed in malignant deseases, while no false positive results have been, at the moment, recorded. (author)

  11. The effect of β-blocker on hamster model BIO 53.58 with dilated cardiomyopathy determined using 123I-MIBG myocardial scintigraphy

    International Nuclear Information System (INIS)

    Inoue, Aritomo; Yamashina, Shohei; Yamazaki, Junichi

    2003-01-01

    123 I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy is currently used to evaluate cardiac sympathetic nerve function, but MIBG also has the capacity to evaluate dilated cardiomyopathy (DCM) severity and therapeutic effectiveness. In this study, we administered β-blockers to a DCM hamster model and evaluated the effect of therapy using MIBG. We also pathologically compared the effects of myocardial fibrosis suppression. BIO 53.58 hamsters were divided into the following five groups based on β-blocker administration: vehicle (COT), 2 mg/kg/day carvedilol (CLT), 20 mg/kg/day (CHT) carvedilol, 4 mg/kg/day (MLT) metoprolol, 40 mg/kg/day (MHT) metoprolol. F1B hamsters were administered a vehicle (COF). Plasma catecholamine, noradrenaline (p-NADR), adrenaline (p-ADR), and dopamine (p-DOPA) were assayed, and MIBG was performed. The count ratio of the heart to the mediastinum (H/M) and left ventricle myocardial washout ratio (WR) were calculated. We then performed an autopsy and calculated the percent change in fibrotic area from myocardial sections. H/M of the initial image in the COT group was significantly lower at 2.4±0.2 than the 2.9±0.7 in the COF group (p<0.05). The CLT and CHT groups had higher H/M values compared to the COT group (3.1±0.6, 3.0±0.6 versus 2.4±0.2: p<0.05). Significant correlations were evident between the H/M of the delayed image and p-NADR and p-DOPA (p<0.05, p<0.01, respectively) as well as between WR and p-NADR and p-DOPA (p<0.05). Percent change in fibrotic area was significantly lower in the β-blocker groups than in the COT group (p<0.05). Significant negative correlations were seen between the H/M of the delayed image and the percent change in fibrosis area. The delayed image H/M and WR acutely reflected cardiac disorder and sympathetic nerve function disorder in BIO 53.58 hamsters. In the carvedilol-administered groups, there was improvement compared to the initial H/M image, indicating the efficacy of the β-blocker in DCM

  12. Relevance of 123I-BMIPP delayed scintigraphic imaging for patients with angina pectoris ? a pilot study

    OpenAIRE

    Koyama, Kohei; Akashi, Yoshihiro J.; Kida, Keisuke; Suzuki, Kengo; Ishibashi, Yuki; Musha, Haruki; Banach, Maciej

    2011-01-01

    Introduction The study was designed to clarify the role of 123I-?-methyl-iodophenylpentadecanoic acid (123I-BMIPP) in the evaluation of myocardial fatty acid metabolism in patients with stable angina pectoris (AP) before and after percutaneous coronary intervention (PCI). Material and methods Ten controls (mean age: 70.4 ?10.5 years) and 12 patients with AP (mean age: 67.4 ?11.6 years) and single vessel coronary artery disease participated in the radionuclide cardiac study. Scintigraphic imag...

  13. Urinary Iodine Concentrations Indicate Iodine Deficiency in Pregnant Thai Women but Iodine Sufficiency in Their School-Aged Children

    NARCIS (Netherlands)

    Gowachirapant, S.; Winichagoon, P.; Wyss, L.; Tong, B.; Baumgartner, J.; Boonstra, A.; Zimmermann, M.B.

    2009-01-01

    The median urinary iodine concentration (UI) in school-aged children is recommended for assessment of iodine nutrition in populations. If the median UI is adequate in school-aged children, it is usually assumed iodine intakes are also adequate in the remaining population, including pregnant women.

  14. Application of 123I-labelled long-chained fatty acids for the study of myocardial metabolism

    International Nuclear Information System (INIS)

    Freundlieb, C.; Hoeck, A.; Vyska, F.; Feinendegen, L.E.; Machulla, H.J.; Stoecklin, G.

    1978-01-01

    Radioiodine-labelled fatty acids are useful tracers for myocardial imaging. The present study extends myocardial scintigraphy with ω-123-I-heptadecanoic acid to measuring myocardial metabolism. 4 normal individuals and 6 patients with cardiac disease received i.v. 1-2 mCi ω-123-I-heptadecanoic acid. Immediately fast serial scintigrams of the myocardium were taken for 30 minutes. Disappearance of the tracer, and appearance of anorganic 123-I, was measured in the peripheral blood. The myocardial images were of high quality later than 5 minutes after injection. By correcting for anorganic 123-I in the peripheral blood and the interstitium, the turnover of tracer in the myocardial cells could be measured. Activity was lost from the myocardium with a half time between 14 and 32 minutes. Within regions of old myocardials infarctions the half time of tracer loss was prolonged. The data clearly indicate the feasibility of using ω-123-I-heptadecanoic acid for measuring myocardial metabolism. (author)

  15. Analysis of regional cerebral blood flow and distribution volume in Machado-Joseph disease by iodine-{sup 123}I IMP single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Tsunemi; Nakajima, Takashi; Fukuhara, Nobuyoshi [National Saigata Hospital, Ohagata, Niigata (Japan)

    2001-09-01

    Machado-Joseph disease (MJD) is an autosomal dominant spinocerebellar ataxia. Its clinical features vary greatly in different generations of the same family. Regional cerebral blood flow (rCBF) and distribution volume (V{sub d}) in the pons, cerebellum, and cerebral cortex were measured in 12 patients with MJD by autoradiography (ARG) and the table look-up (TLU) method of iodine-123 IMP ({sup 123}I-IMP) single photon emission computed tomography (SPECT). Representative cases were as follows: A 46-year-old woman first experienced gait ataxia at age 38. Computed tomography (CT) and magnetic resonance imaging (MRI) showed no atrophy in the pons or cerebellum, but rCBF measured by the {sup 123}I-IMP SPECT ARG method detected hypoperfusion in the pons, and cerebellar vermis and hemisphere. A 76-year-old woman first experienced gait ataxia at age 69. CT and MRI findings showed severe atrophy in the pons, and cerebellar vermis and hemisphere. Moreover, rCBF was decreased in the pons, whereas it was not decreased in the cerebellar vermis and hemisphere. In the pons of patients with MJD, rCBF was markedly decreased regardless of disease severity. Because this SPECT finding for the pons looked like a 'dot', we have called it the 'pontine dot sign'. In the MJD group, rCBF was significantly decreased in the pons (Student's t test, p<0.01) and cerebellar vermis (p<0.05). The V{sub d} was also significantly decreased in the pons (p<0.005) in comparison with that for normal subjects. Pearson's correlation analysis yielded a significant relationship between the rCBF in the pons and age at onset (r=0.578, p<0.05). There was a strong correlation between the V{sub d} for the pons and age at onset (r=0.59, p<0.05). Person's correlation analysis also showed a significant relationship between the V{sub d} in the cerebellar hemispheres and International Cooperative Ataxia Rating Scale (r=0.644, p<0.05). The pontine rCBFs in patients with early onset MJD

  16. Monte Carlo simulations used to calculate the energy deposited in the coronary artery lumen as a function of iodine concentration and photon energy.

    Science.gov (United States)

    Hocine, Nora; Meignan, Michel; Masset, Hélène

    2018-04-01

    To better understand the risks of cumulative medical X-ray investigations and the possible causal role of contrast agent on the coronary artery wall, the correlation between iodinated contrast media and the increase of energy deposited in the coronary artery lumen as a function of iodine concentration and photon energy is investigated. The calculations of energy deposition have been performed using Monte Carlo (MC) simulation codes, namely PENetration and Energy LOss of Positrons and Electrons (PENELOPE) and Monte Carlo N-Particle eXtended (MCNPX). Exposure of a cylinder phantom, artery and a metal stent (AISI 316L) to several X-ray photon beams were simulated. For the energies used in cardiac imaging the energy deposited in the coronary artery lumen increases with the quantity of iodine. Monte Carlo calculations indicate a strong dependence of the energy enhancement factor (EEF) on photon energy and iodine concentration. The maximum value of EEF is equal to 25; this factor is showed for 83 keV and for 400 mg Iodine/mL. No significant impact of the stent is observed on the absorbed dose in the artery for incident X-ray beams with mean energies of 44, 48, 52 and 55 keV. A strong correlation was shown between the increase in the concentration of iodine and the energy deposited in the coronary artery lumen for the energies used in cardiac imaging and over the energy range between 44 and 55 keV. The data provided by this study could be useful for creating new medical imaging protocols to obtain better diagnostic information with a lower level of radiation exposure.

  17. Recovered neuronal viability revealed by Iodine-123-iomazenil SPECT following traumatic brain injury.

    Science.gov (United States)

    Koizumi, Hiroyasu; Fujisawa, Hirosuke; Kurokawa, Tetsu; Suehiro, Eiichi; Iwanaga, Hideyuki; Nakagawara, Jyoji; Suzuki, Michiyasu

    2010-10-01

    We evaluated cortical damages following traumatic brain injury (TBI) in the acute phase with [(123)I] iomazenil (IMZ) single photon emission computed tomography (SPECT). In all, 12 patients with cerebral contusion following TBI were recruited. All patients underwent IMZ SPECT within 1 week after TBI. To investigate the changes in distribution of IMZ in the cortex in the chronic phase, after conventional treatment, patients underwent IMZ SPECT again. A decrease in the accumulation of radioligand for the central benzodiazepine receptor in the cortex corresponding to the contusion revealed with computed tomography (CT) scans and magnetic resonance imaging (MRI) were shown on IMZ SPECT in the acute phase in all patients. In 9 of 12 patients (75%), images of IMZ SPECT obtained in the chronic phase of TBI showed that areas with a decreased distribution of IMZ were remarkably reduced in comparison with those obtained in the acute phase. Both CT scans and MRI showed a normal appearance of the cortex morphologically, where the binding potential of IMZ recovered in the chronic phase. Reduced binding potential of radioligand for the central benzodiazepine receptor is considered to be an irreversible reaction; however, in this study, IMZ accumulation in the cortex following TBI was recovered in the chronic phase in several patients. [(123)I] iomazenil SPECT may have a potential to disclose a reversible vulnerability of neurons following TBI.

  18. Association of myocardial inotropic reserve and adrenergic nerve alterations in idiopathic dilated cardiomyopathy. A dobutamine stress echocardiographic and 123-I-MIBG scintigraphic study

    International Nuclear Information System (INIS)

    Prassopoulos, V.P.; Koukouraki, S.; Velidaki, A.; Karkavitsas, N.; Parthenakis, F.; Patrianakos, A.; Kochiadakis, G.; Papadimitriou, E.; Vardas, P.

    2002-01-01

    Aim: Evaluation of contractile reserve is important in congestive hear failure. The aim of this study was to examine the relationship between the myocardial response to dobutamine by stress echocardiography and the sympathetic nerve alterations by 123-I-Metaiodobenzylguanidine (MIBG)scintigraphy and how both contribute to predict exercise capacity in patients with idiopathic dilated cardiomyopathy. Materials-Methods: We studied 20 patients with idiopathic dilated cardiomyopathy (IDC) and ejection fraction < 45% (M/F 13/7, age 56±11 years) while 15 healthy individuals served as controls. Echocardiography and myocardial scintigraphic study with 123-I- MIBG, provided quantitative assessment of left ventricular (LV) wall motion and heart to mediastinum uptake(H/M) ratio and washout. All patients underwent a cardiopulmonary exercise test with a modified Naughton protocol and gas exchange data were analyzed. According to LV response to dobutamine, patients were divided into two groups: those in whom contractility improved in ≥ five segments (Group I: 11 patients) and those in whom contractility improved in < 5 segments (Group II : 9 patients). Results: MIBG uptake was significantly lower in patients than in controls (p < 0.001). MIBG uptake and washout was higher in Group I compared to Group II (P<0,01 and p<0,05). Late MIBG H/M was correlated with resting ejection fraction (r=0,70), wall motion score index (WMSI) (r=-0,50), end systolic wall stress (r=-0,61), washout (r=-0,57), and oxygen consumption at peak exercise (r=0,64) and at anaerobic threshold (r=0,67). LV ejection fraction increased in both groups at Dobutamine, with a higher increase in Group I (p=0,008). WMSI changes at dobutamine correlated significantly with resting ejection fraction (r=0,46) early (r=0,53) and late (r=0,54) MIBG. Multivariate analysis revealed that only the late MIBG uptake was independently associated with the improvement in WMSI. Conclusions: The present data indicate that in

  19. Iodine generator for reclaimed water purification

    Science.gov (United States)

    Wynveen, R. A.; Powell, J. D.; Schubert, F. H. (Inventor)

    1977-01-01

    The system disclosed is for controlling the iodine level in a water supply in a spacecraft. It includes an iodine accumulator which stores crystalline iodine, an electrochemical valve to control the input of iodine to the drinking water and an iodine dispenser. A pump dispenses fluid through the iodine dispenser and an iodine sensor to a potable water tank storage. The iodine sensor electronically detects the iodine level in the water, and through electronic means, produces a correction current control. The correction current control operates the electro-chemical iodine valve to release iodine from the iodine accumulator into the iodine dispenser.

  20. Dosimetric contribution of organs of biokinetics of {sup 99m}Tc and {sup 123}I to estimate radiation doses in thyroids of children of 1 and 5 years; Contribucion dosimetrica de organos de la biocinetica del {sup 99m}Tc y {sup 123}I para estimar dosis en tiroides de ninos de 1 y 5 anos

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, M.V.; Castillo, C.E.; Abanto, D.M.; Rocha, D.; Garcia, W.H.; Marin, K., E-mail: marvva@hotmail.com [Universidad Nacional de Trujillo (UNT), Trujillo (Peru); Quispe, R. [Centro de Ciencias Aplicadas y Desarrollo Tecnologico, UNAM, Mexico (Mexico)

    2015-07-01

    The absorbed doses by thyroids during uptake studies through biokinetics of radiopharmaceuticals containing {sup 123}I (iodine) or {sup 99m}Tc (pertechnetate) are estimated. Using the MIRD scheme and the representation of Cristy-Eckerman for thyroids in children of 1 and 5 years, the objective of the study was to determine whether the dosimetric biokinetic contributions of the organs of {sup 123}I (iodide) and {sup 99m}Tc (pertechnetate) biokinetic are significant in the estimated of the absorbed dose for thyroid uptake studies.

  1. Synthesis and biodistribution of 2-[{sup 123}I]iodomelatonin in normal mice

    Energy Technology Data Exchange (ETDEWEB)

    Al-Jammaz, I. [Cyclotron and Radiopharmaceuticals Department, King Faisal Specialist Hospital and Research Centre, P.O. Box 3354, Riyadh 11211 (Saudi Arabia)]. E-mail: jammaz@kfshrc.edu.sa; Al-Otaibi, B. [Cyclotron and Radiopharmaceuticals Department, King Faisal Specialist Hospital and Research Centre, P.O. Box 3354, Riyadh 11211 (Saudi Arabia); Aboul-Enein, H. [Cyclotron and Radiopharmaceuticals Department, King Faisal Specialist Hospital and Research Centre, P.O. Box 3354, Riyadh 11211 (Saudi Arabia); Amartey, J.K. [Cyclotron and Radiopharmaceuticals Department, King Faisal Specialist Hospital and Research Centre, P.O. Box 3354, Riyadh 11211 (Saudi Arabia)

    2006-01-01

    Melatonin demands that this hormone and its receptors be well understood. With this aim in mind, synthetic melatonin was radioiodinated with no-carrier-added (n.c.a.) sodium iodide-123 using in situ generated peracetic acid as oxidizing agent for electrophilic iodination at room temperature. The radiochemical yield was typically greater than 80% after 20 min reaction time especially when relatively small amounts of activities were used (10 mCi). Biological evaluation was performed in normal mice. The distribution of the tracer did not reveal any specificity during the time frame studied. There was no significant retention in the whole brain.

  2. Iodination and stability of somatostatin analogues: comparison of iodination techniques. A practical overview.

    Science.gov (United States)

    de Blois, Erik; Chan, Ho Sze; Breeman, Wouter A P

    2012-01-01

    For iodination ((125/127)I) of tyrosine-containing peptides, chloramin-T, Pre-Coated Iodo-Gen(®) tubes and Iodo-Beads(®) (Pierce) are commonly used for in vitro radioligand investigations and there have been reliant vendors hereof for decades. However, commercial availability of these radio-iodinated peptides is decreasing. For continuation of our research in this field we investigated and optimized (radio-)iodination of somatostatin analogues. In literature, radioiodination using here described somatostatin analogues and iodination techniques are described separately. Here we present an overview, including High Performance Liquid Chromatography (HPLC) separation and characterisation by mass spectrometry, to obtain mono- and di-iodinated analogues. Reaction kinetics of (125/127)I iodinated somatostatin analogues were investigated as function of reaction time and concentration of reactants, including somatostatin analogues, iodine and oxidizing agent. To our knowledge, for the here described somatostatin analogues, no (127)I iodination and optimization are described. (Radio-)iodinated somatostatin analogues could be preserved with a >90% radiochemical purity for 1 month after reversed phase HPLC-purification.

  3. Chemical species of iodine in some seaweeds. Pt. 2. Iodine-bound biological macromolecules

    International Nuclear Information System (INIS)

    Xiaolin Hou; Chifang Chai; Xiaojun Yan

    2000-01-01

    The distribution of iodine in various biological macromolecules in Sargassum kjellmanianum was studied using neutron activation analysis combined with chemical and biochemical separation techniques. The results indicate that iodine is mainly bound with protein, part of iodine with pigment and polyphenol, and little with polysaccharides, such as algin, fucoidan and cellulose. This result is significant for the mechanism of enriching iodine of algae and utilization of alga iodine. (author)

  4. Modeling an Iodine Hall Thruster Plume in the Iodine Satellite (ISAT)

    Science.gov (United States)

    Choi, Maria

    2016-01-01

    An iodine-operated 200-W Hall thruster plume has been simulated using a hybrid-PIC model to predict the spacecraft surface-plume interaction for spacecraft integration purposes. For validation of the model, the plasma potential, electron temperature, ion current flux, and ion number density of xenon propellant were compared with available measurement data at the nominal operating condition. To simulate iodine plasma, various collision cross sections were found and used in the model. While time-varying atomic iodine species (i.e., I, I+, I2+) information is provided by HPHall simulation at the discharge channel exit, the molecular iodine species (i.e., I2, I2+) are introduced as Maxwellian particles at the channel exit. Simulation results show that xenon and iodine plasma plumes appear to be very similar under the assumptions of the model. Assuming a sticking coefficient of unity, iodine deposition rate is estimated.

  5. Separation of iodine-131 from water using isotopic exchange with iodine-starch compound

    International Nuclear Information System (INIS)

    Ignatov, V.P.; Kolomejtseva, I.V.

    1990-01-01

    Conditions of iodine isotopic exchange with iodine-starch compound (ISC) were studied with the aim of compound utilizatoin for radioactive iodine separation from solution. It is shown that in pH range from 2 to 7 the degree of iodine extraction and coefficient of its distribution practically do not depend on pH, at pH>7 ISC destruction (decolorizing) starts and iodine extraction decreases. Rapid method of iodine separation from solution is suggested. The method can be used in radiochemical techniques. The degree of extraction equals 80 %, a higher degree of extraction can not be achieved owing to ISC formation peculiarities

  6. Iodine budget in surface waters from Atacama: Natural and anthropogenic iodine sources revealed by halogen geochemistry and iodine-129 isotopes

    International Nuclear Information System (INIS)

    Álvarez, Fernanda; Reich, Martin; Snyder, Glen; Pérez-Fodich, Alida; Muramatsu, Yasuyuki; Daniele, Linda; Fehn, Udo

    2016-01-01

    Iodine enrichment in the Atacama Desert of northern Chile is widespread and varies significantly between reservoirs, including nitrate-rich “caliche” soils, supergene Cu deposits and marine sedimentary rocks. Recent studies have suggested that groundwater has played a key role in the remobilization, transport and deposition of iodine in Atacama over scales of millions-of-years. However, and considering that natural waters are also anomalously enriched in iodine in the region, the relative source contributions of iodine in the waters and its extent of mixing remain unconstrained. In this study we provide new halogen data and isotopic ratios of iodine ("1"2"9I/I) in shallow seawater, rivers, salt lakes, cold and thermal spring water, rainwater and groundwater that help to constrain the relative influence of meteoric, marine and crustal sources in the Atacama waters. Iodine concentrations in surface and ground waters range between 0.35 μM and 26 μM in the Tarapacá region and between 0.25 μM and 48 μM in the Antofagasta region, and show strong enrichment when compared with seawater concentrations (I = ∼0.4 μM). In contrast, no bromine enrichment is detected (1.3–45.7 μM for Tarapacá and 1.7–87.4 μM for Antofagasta) relative to seawater (Br = ∼600 μM). These data, coupled to the high I/Cl and low Br/Cl ratios are indicative of an organic-rich sedimentary source (related with an “initial” fluid) that interacted with meteoric water to produce a mixed fluid, and preclude an exclusively seawater origin for iodine in Atacama natural waters. Iodine isotopic ratios ("1"2"9I/I) are consistent with halogen chemistry and confirm that most of the iodine present in natural waters derives from a deep initial fluid source (i.e., groundwater which has interacted with Jurassic marine basement), with variable influence of at least one atmospheric or meteoric source. Samples with the lowest isotopic ratios ("1"2"9I/I from ∼215 to ∼1000 × 10"

  7. Iodine mineral waters

    Directory of Open Access Journals (Sweden)

    Iluta Alexandru

    2011-11-01

    Full Text Available Iodine mineral waters are found especially in sub-Carpathian region, also in regions with Salif deposits. Waters are currently used iodine in drinking cure for chaps and Basedow. Are also indicated in balneology. Iodine water containing at least 1 mg L, there is pure iodine is usually given the nature of other types of mineral waters further: sodium chlorinated water (Bazna (50-70 mg iodine / l, Baile Govora (50 - 70 mg / l, Bălţăteşti (4-5 mg / l, salted Monteoru (30 mg / l, mine water mixed alkaline chlorination, sulphate, which are indicated for crenoterapie (hypo or isotonic to the bathrooms Olăneşti or Călimăneşti-Căciulata.

  8. Iodine status in neonates in Denmark: regional variations and dependency on maternal iodine supplementation

    DEFF Research Database (Denmark)

    Nøhr, S B; Laurberg, P; Børlum, K G

    1994-01-01

    Iodine status of 147 neonates born in five different regions of Denmark was evaluated in relation to the iodine content of breast milk and iodine supplementation taken by the mother. Approximately two-thirds of the women had not received iodine supplementation. They had low iodine concentrations...... in breast milk and urinary iodine concentrations of the neonates at day 5 were low. The median values (milk/urine) were 33.6/31.7 micrograms/l (Randers 22/26, Ringkøbing 29/16, Aalborg 36/31. Arhus 54/41 and Copenhagen 55/59 micrograms/l). Higher values were found in the group where tablets containing...... iodine had been taken (milk/urine: 57.0/61.0 micrograms/l). In general, the values are low compared with internationally recommended levels. We suggest that mothers without autoimmune thyroid disease should receive iodine supplementation in the form of vitamin/mineral tablets containing iodine (150...

  9. Urinary Iodine Clearance following Iodinated Contrast Administration: A Comparison of Euthyroid and Postthyroidectomy Subjects

    Directory of Open Access Journals (Sweden)

    Janice D. Ho

    2014-01-01

    Full Text Available Purpose. To compare iodine clearance following iodinated contrast administration in thyroidectomised thyroid cancer patients and euthyroid individuals. Methods. A convenience population (6 thyroidectomised thyroid cancer patients and 7 euthyroid controls was drawn from patients referred for iodinated contrast-enhanced computed tomography (CT studies. Subjects had sequential urine samples collected up to 6 months (50 samples from the thyroidectomised and 63 samples from the euthyroid groups. t-tests and generalised estimating equations (GEE were used to test for group differences in urinary iodine creatinine ratios. Results. Groups had similar urinary iodine creatinine ratios at baseline, with a large increase 2 weeks following iodinated contrast (P=0.005. Both groups had a return of urinary iodine creatinine ratios to baseline by 4 weeks, with no significant group differences overall or at any time point. Conclusions. Thyroidectomised patients did not have a significantly different urinary iodine clearance than euthyroid individuals following administration of iodinated contrast. Both had a return of urinary iodine creatinine ratios to baseline within 4 weeks.

  10. The radiotoxicology of iodine

    International Nuclear Information System (INIS)

    Taylor, D.M.

    1981-01-01

    Thirty radioisotopes of iodine are known but only those with mass numbers from 123 to 135 are of major radiotoxicological interest. Exposure of animals or man to inorganic 131 I or 125 I may result in the induction of benign or malignant thyroid tumors or depression of thyroid function; Bq for Bq 125 I is less toxic than 131 I. However, the shorter lived radioiodines 132 I, 133 I, and 135 I appear to be 10 to 100 times more toxic than 131 I alone. Little information is available about the toxicity of radioiodine containing organic compounds. The DNA precursor, iododeoxyuridine when labelled with 125 I becomes incorporated into the cell nucleus and produces severe and often irreparable damage due to the emission of Auger electrons. The risk estimate for the induction of thyroid carcinoma or adenoma by inorganic 131 I is considered to be 10 to 20x10 -6 persons Gy -1 y -1 , but may be up to 100 times larger for persons exposed to mixtures of short-lived radioiodines. (author)

  11. Differention of parkinson's disease, multiple system atrophy and pure autonomic failure using I-123 MIBG myocardial scintigraphy

    International Nuclear Information System (INIS)

    Zhang, Z.; Religiosol, D.; Machac, J.; Nahm, K.F.; Kaufmann, H.C.; Yahr, M.D.

    2004-01-01

    Purpose: Clinical differentiation of Parkinson's disease (PD), multiple system atrophy (MSA), and pure autonomic failure (PAF) may be difficult. 123I MIBG studies have shown significantly reduced cardiac uptake in patient with PD but not in MSA suggesting that postganglionic neurons are only affected in PD. No systematic study using 123I MIBG in patients with PAF has been reported. The Objective of this study is to investigate whether MSA, PD, and PAF can be differentiated by 1231 MIBG myocardial scintigraphy. Methods: 1231 MIBG was synthesized using Cu(I) assisted kit method (labeling efficiency 99.84±0.47%, n = 17). Five patients with a clinical diagnosis of MSA (age 63±11), 4 with PD (62±10), 4 with PAF (60±7), and 3 normal controls (50±19) were referred to NM blinded to the categories of the patients. SPECT and planar chest imaging was taken 15 min (early) and 4 hours (delayed) postinjection of 200-351 MBq 123I MIBG using a Picker triple head SPECT camera. Regions of interest were placed over the heart (H) and mediastinum (M); the average count ratios (H/M) were calculated. Each subject had a separate 201Tl perfusion imaging to exclude significant myocardial perfusion defects. Results: As shown in the Table, the H/M ratio in patients with MSA was significantly lower than that in normal subjects (P = 0.027) in early imaging, but not in the delayed imaging. Both H/M ratios in PD and PAF were significantly lower than that in MSA in early (P = 0.006, P = 0.008) and delayed (P< 0.0001, P < 0.00001) imaging. Only delayed uptake ratio showed significant difference (P = 0.013) between PD and PAF. Conclusions: 123I MIBG cardiac uptake in delayed imaging was significantly reduced in patients with PD and PAF while it was normal in MSA. Significant cardiac uptake difference was also found between PD and PAF. 123I MIBG myocardial scintigraphy appears to provide helpful information in the differential diagnosis of these disorders. (authors)

  12. Evaluation of image reconstruction methods for 123I-MIBG-SPECT. A rank-order study

    International Nuclear Information System (INIS)

    Soederberg, Marcus; Mattsson, Soeren; Oddstig, Jenny; Uusijaervi-Lizana, Helena; Leide-Svegborn, Sigrid; Valind, Sven; Thorsson, Ola; Garpered, Sabine; Prautzsch, Tilmann; Tischenko, Oleg

    2012-01-01

    Background: There is an opportunity to improve the image quality and lesion detectability in single photon emission computed tomography (SPECT) by choosing an appropriate reconstruction method and optimal parameters for the reconstruction. Purpose: To optimize the use of the Flash 3D reconstruction algorithm in terms of equivalent iteration (EI) number (number of subsets times the number of iterations) and to compare with two recently developed reconstruction algorithms ReSPECT and orthogonal polynomial expansion on disc (OPED) for application on 123 I-metaiodobenzylguanidine (MIBG)-SPECT. Material and Methods: Eleven adult patients underwent SPECT 4 h and 14 patients 24 h after injection of approximately 200 MBq 123 I-MIBG using a Siemens Symbia T6 SPECT/CT. Images were reconstructed from raw data using the Flash 3D algorithm at eight different EI numbers. The images were ranked by three experienced nuclear medicine physicians according to their overall impression of the image quality. The obtained optimal images were then compared in one further visual comparison with images reconstructed using the ReSPECT and OPED algorithms. Results: The optimal EI number for Flash 3D was determined to be 32 for acquisition 4 h and 24 h after injection. The average rank order (best first) for the different reconstructions for acquisition after 4 h was: Flash 3D 32 > ReSPECT > Flash 3D 64 > OPED, and after 24 h: Flash 3D 16 > ReSPECT > Flash 3D 32 > OPED. A fair level of inter-observer agreement concerning optimal EI number and reconstruction algorithm was obtained, which may be explained by the different individual preferences of what is appropriate image quality. Conclusion: Using Siemens Symbia T6 SPECT/CT and specified acquisition parameters, Flash 3D 32 (4 h) and Flash 3D 16 (24 h), followed by ReSPECT, were assessed to be the preferable reconstruction algorithms in visual assessment of 123 I-MIBG images

  13. [Study on the iodine nutrition and iodine deficiency disorders status in pasturing areas of Tibet-a non-epidemic area of iodine deficiency disorders in serious iodine deficiency district].

    Science.gov (United States)

    DU, Dan; Li, Su-Mei; Li, Xiu-Wei; Wang, Hai-Yan; Li, Shu-Hua; Nima, Cangjue; Danzeng, Sangbu; Zhuang, Guang-Xiu

    2010-08-01

    To explore the status of iodine nutrition and iodine deficiency disorders in the pasturing areas and agricultural regions in Tibet. 30 families were selected respectively in pastoral Dangxiong county and agricultural Qushui county of Lasa. Drinking water and edible salt were collected for testing the iodine contents. In each type of the following populations including children aged 8 - 10, women of child-bearing age and male adults, 50 subjects were randomly sampled to examine their urinary iodine contents. Among them, 50 children and 50 women were randomly selected for goiter examination by palpation. Water iodine content was less than 2 µg/L, both in pasturing area and in agricultural areas. There was no iodized salt used in the families of pasturing areas, while 90% people consumed iodized salt in agricultural areas. The median of urinary iodine in pasturing area was 50.2 µg/L, significantly lower than that of agricultural area (193.2 µg/L). However, the goiter rate of children and women in pasturing area was significantly lower than that in agricultural area. Although iodine intake of populations in pasturing area of Tibet was severely deficient, there was no epidemic of Iodine Deficiency Disorders. This phenomenon noticed by the researchers deserved further investigation.

  14. Iodine deficiency disorders

    Energy Technology Data Exchange (ETDEWEB)

    Ali, S M [Pakistan Council for Science and Technology, Islamabad (Pakistan)

    1994-12-31

    Iodine deficiency (IDD) is one of the common problem in the diet. Iodine deficiency as prevalence of goiter in population occurs in the mountainous areas. There is consensus that 800 million people are at risk of IDD from living in iodine deficient area and 190 million from goiter. Very high prevalence of IDD in different parts of the world are striking. It has generally observed that in iodine-deficient areas about 50% are affected with goiter, 1-5% from cretinsim and 20% from impaired mental and/or mortor function. (A.B.).

  15. Iodine deficiency and thyroid disorders.

    Science.gov (United States)

    Zimmermann, Michael B; Boelaert, Kristien

    2015-04-01

    Iodine deficiency early in life impairs cognition and growth, but iodine status is also a key determinant of thyroid disorders in adults. Severe iodine deficiency causes goitre and hypothyroidism because, despite an increase in thyroid activity to maximise iodine uptake and recycling in this setting, iodine concentrations are still too low to enable production of thyroid hormone. In mild-to-moderate iodine deficiency, increased thyroid activity can compensate for low iodine intake and maintain euthyroidism in most individuals, but at a price: chronic thyroid stimulation results in an increase in the prevalence of toxic nodular goitre and hyperthyroidism in populations. This high prevalence of nodular autonomy usually results in a further increase in the prevalence of hyperthyroidism if iodine intake is subsequently increased by salt iodisation. However, this increase is transient because iodine sufficiency normalises thyroid activity which, in the long term, reduces nodular autonomy. Increased iodine intake in an iodine-deficient population is associated with a small increase in the prevalence of subclinical hypothyroidism and thyroid autoimmunity; whether these increases are also transient is unclear. Variations in population iodine intake do not affect risk for Graves' disease or thyroid cancer, but correction of iodine deficiency might shift thyroid cancer subtypes toward less malignant forms. Thus, optimisation of population iodine intake is an important component of preventive health care to reduce the prevalence of thyroid disorders. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Iodine Status in Pregnant & Breastfeeding Women

    DEFF Research Database (Denmark)

    Andersen, Stine Linding

    Iodine is required for the synthesis of thyroid hormones, which are crucial regulator of early brain development. The source of iodine in the fetus and the breastfed infant is maternal iodine, and adequate iodine intake in pregnant and breastfeeding is of major concern. Severe iodine deficiency can...... cause irreversible brain damage, whereas the consequences of mild to moderate iodine deficiency are less clear. Denmark was previously iodine deficient with regional differences (mild iodine deficiency in East Denmark and moderate iodine deficiency in West Denmark), and also pregnant and breastfeeding...... women suffered from iodine deficiency. A mandatory iodine fortification of household salt and salt used for commercial production of bread was introduced in Denmark in the year 2000. The PhD thesis investigates intake of iodine supplements and urinary iodine status in Danish pregnant and breastfeeding...

  17. Consuming iodine enriched eggs to solve the iodine deficiency endemic for remote areas in Thailand

    Directory of Open Access Journals (Sweden)

    Teeyapant Punthip

    2010-12-01

    Full Text Available Abstract Background Evidence showed that the occurrence of iodine deficiency endemic areas has been found in every provinces of Thailand. Thus, a new pilot programme for elimination of iodine deficiency endemic areas at the community level was designed in 2008 by integrating the concept of Sufficient Economic life style with the iodine biofortification of nutrients for community consumption. Methods A model of community hen egg farm was selected at an iodine deficiency endemic area in North Eastern part of Thailand. The process for the preparation of high content iodine enriched hen food was demonstrated to the farm owner with technical transfer in order to ensure the sustainability in the long term for the community. The iodine content of the produced iodine enriched hen eggs were determined and the iodine status of volunteers who consumed the iodine enriched hen eggs were monitored by using urine iodine excretion before and after the implement of iodine enrichment in the model farm. Results The content of iodine in eggs from the model farm were 93.57 μg per egg for the weight of 55 - 60 g egg and 97.76 μg for the weight of 60 - 65 g egg. The biological active iodo-organic compounds in eggs were tested by determination of the base-line urine iodine of the volunteer villagers before and after consuming a hard boiled iodine enriched egg per volunteer at breakfast for five days continuous period in 59 volunteers of Ban Kew village, and 65 volunteers of Ban Nong Nok Kean village. The median base-line urine iodine level of the volunteers in these two villages before consuming eggs were 7.00 and 7.04 μg/dL respectively. After consuming iodine enriched eggs, the median urine iodine were raised to the optimal level at 20.76 μg/dL for Ban Kew and 13.95 μg/dL for Ban Nong Nok Kean. Conclusions The strategic programme for iodine enrichment in the food chain with biological iodo-organic compound from animal origins can be an alternative method to

  18. Iodine in meat in Macedonia

    International Nuclear Information System (INIS)

    Bogdanov, Bogdan; Gonev, Mihajlo; Tadzher, Isak

    2000-01-01

    Iodine deficiency in Macedonia still persists in a mild form. In 1999 the iodination of salt rose to 20 m gr iodine in Kg salt. The consumption of salt diminished after the last war from 20-30 gr salt per day to 10-20 gr salt daily. This shows that the problem of the elimination of iodine deficiency is being vigorously tackled. Since 1956 the iodine in salt in Macedonia rose to 10 m gr KI/Kg salt. The content of iodine in the Macedonian diet seems to be important. The amount of iodine in milk, eggs and bread is low as found by the investigation of MANU. The content of iodine in meat is low, compared to British meat is 10 times lower. The average iodine content in Macedonian meat is 95.15 micro gr per Kg, whereas in British meat it is 850-1510 micro gr iodine per k gr meat. (Original)

  19. Radiosynthesis and biological evaluation of "1"2"3 I(±)trans-2-hydroxy-5-((E)-3-(iodo)allyloxy)-3-(4-phenyl-1-piperazinyl) tetralin

    International Nuclear Information System (INIS)

    Assaad, T.; Alrayyes, A.

    2013-01-01

    This work reports both the radiolabeling and preliminary biodistribution results in rats brain of (±)-["1"2"3 I]-II. The novel benzovesamicol derivative (±)-["1"2"3 I]-II was successfully labeled with iodine-"1"2"3 from its corresponding n-tributyltin, with radiochemical purity greater than 97% and radiochemical yield in the range 50 - 55%. (±)-["1"2"3 I]- II showed a higher accumulation in striatum than in the other regions studied. To determine if (±)-["1"2"3 I]-II could provide an advantage compared to reference compound ["1"2"5 I]-IBVM, a kinetic study was carried out, at each point of the kinetic study, (±)-["1"2"3 I]-II showed a lower specific binding compared to ["1"2"5 I]-IBVM. Time activity curves of (±)-["1"2"3 I]-II confirmed that this compound inferior to ["1"2"5 I]-IBVM to explore the VAChT in vivo by SPECT. Moreover, it is well known that interaction at the VAChT binding site is enantioselective, and therefore, working with enantiomerically pure compounds, could improve the compound activity.(author)

  20. Role of 123I-IMP SPET in the early diagnosis of borderline chronic hydrocephalus after aneurysmal subarachnoid haemorrhage

    International Nuclear Information System (INIS)

    Ohkuma, Hiroki; Tanaka, Masahiko; Suzuki, Shigeharu; Kondoh, Izumi

    2000-01-01

    Chronic hydrocephalus after aneurysmal subarachnoid haemorrhage (SAH) is easily diagnosed in most cases. However, the diagnosis is sometimes difficult in borderline cases, in which (a) pathognomonic clinical deterioration due to hydrocephalus is masked by the neurological deficits caused in the acute stage of SAH and (b) ventricular enlargement is not so marked on CT scan. The purpose of this study was to investigate whether or not iodine-123 labelled N-isopropyl-p-iodoamphetamine ( 123 I-IMP) single-photon emission tomography (SPET) is of value for the early diagnosis of borderline chronic hydrocephalus after SAH. Fifteen patients who met the criteria of borderline chronic hydrocephalus were selected for the study, and underwent a shunt operation. The patients were divided into a shunt-effective group and a shunt-ineffective group according to neurological improvement after the shunt operation. 123 I-IMP SPET was performed in the acute stage of SAH, within 1 week before the shunt operation, and 2 weeks after the shunt operation. Regional cerebral blood flow was estimated by the 123 I-IMP autoradiographic method. Pre-shunting periventricular low-perfusion areas showed statistically significant differences between the two groups (P 123 I-IMP SPET can be used for both the early diagnosis of borderline chronic hydrocephalus after SAH and the prediction of shunt effectiveness. (orig.)