WorldWideScience

Sample records for carbon 11 beams

  1. Plasma beam discharge in carbon dioxide

    International Nuclear Information System (INIS)

    The paper deals with the dissociation of carbon dioxide in nonequilibrium plasma of a stationary plasma-beam discharge. Experimental results of spectroscopic and probe measurements of plasma parameters are given. Moreover, a mass-spectrometric analysis of gaseous products of the chemical reactions is presented. In addition the measurement of the deposition rate of solid products by means of a quartz oscillator is described. The results show that plasma beam discharge is an effective tool for inducing plasma-chemical reactions. (author)

  2. Carbon beams, production and acceleration

    International Nuclear Information System (INIS)

    Installation, test and working conditions of a new negative-ion facility of the Salazar EN tandem are briefly described. Carbon is the material used for the test and the heavy ion stripping phenomenon is reviewed. (author)

  3. Studies to label Alfentanil with carbon-11

    Energy Technology Data Exchange (ETDEWEB)

    Feliu, A.L. (Forschungzentrum Juelich GmbH (Germany). Inst. fuer Chemie I)

    1992-09-01

    Methodology applicable to the synthesis of no-carrier-added (O-methyl-{sup 11}C)alfentanil was developed. The sequence consisted of ({sup 11}C)methylation and propionylation of N-aryl-4-(hydroxymethyl)-4-(N-anilino)-piperidines 1a and 1c, followed by the chemoselective hydrolysis of bulk byproducts to facilitate isolation of the NCA carbon-11-labeled product by prep-HPLC. All three steps could be performed without isolation of intermediates in a single reaction vessel. (author).

  4. Electron beam processing of carbon fibre reinforced braided composites beams

    International Nuclear Information System (INIS)

    Complete text of publication follows. In this paper the possibility of producing a new type carbon fiber reinforced composite is examined by applying braiding, a well-known process of textile technology. The appearance of the new Hungarian carbon fiber with excellent mechanical properties in the market enables the development of newer type carbon fiber reinforced composites in the continuously widening range of engineering applications. Advanced hollow profiles, pipes and other composite products can be manufactured in continuous operation. A new way of composite production of this kind is the manufacturing of reinforcing structure by braiding technology producing a composite with sufficient mechanical properties from this cross directional fabric-like textile structure by impregnation. This manufacturing process can complete the variety of hollow products serving the same purpose as pultrusion or filament winding. This way a profile type framework element with a hollow cross section is manufactured having favorable mechanical properties. Owing to its small mass and high specific strength this product can be applied in dynamically loaded structures e.g. in the automotive industry. For crosslinking of the matrix the method of high-speed electron beam curing has been examined in order to reach continuous operation. The field of use and application of carbon fiber braided structures has a great chance especially in machine engineering and in the automotive industry. The main reason for this is that braiding processes are capable of producing structures having good mechanical properties at a low processing price. The mass of the composite load-bearing structure produced this way is one fifth of the steel product having similar geometry, and its specific mechanical properties are nearly as good as that of the most commonly applied semiproduct and structural component, the welded steel profile

  5. Intensive irradiation of carbon nanotubes by Si ion beam

    Institute of Scientific and Technical Information of China (English)

    NI Zhichun; LI Qintao; YAN Long; GONG Jinlong; ZHU Dezhang; ZHU Zhiyuan

    2007-01-01

    Multi-walled carbon nanotubes were irradiated with 40 keV Si ion beam to a dose of 1×1017 cm-2. The multiple-way carbon nanowire junctions and the Si doping in carbon nanowires were realized. Moreover, the formation processes of carbon nanowire junctions and the corresponding mechanism were studied.

  6. Shunting arc plasma source for pure carbon ion beam

    Energy Technology Data Exchange (ETDEWEB)

    Koguchi, H.; Sakakita, H.; Kiyama, S.; Shimada, T.; Sato, Y.; Hirano, Y. [Energy Technology Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan)

    2012-02-15

    A plasma source is developed using a coaxial shunting arc plasma gun to extract a pure carbon ion beam. The pure carbon ion beam is a new type of deposition system for diamond and other carbon materials. Our plasma device generates pure carbon plasma from solid-state carbon material without using a hydrocarbon gas such as methane gas, and the plasma does not contain any hydrogen. The ion saturation current of the discharge measured by a double probe is about 0.2 mA/mm{sup 2} at the peak of the pulse.

  7. Shunting arc plasma source for pure carbon ion beam.

    Science.gov (United States)

    Koguchi, H; Sakakita, H; Kiyama, S; Shimada, T; Sato, Y; Hirano, Y

    2012-02-01

    A plasma source is developed using a coaxial shunting arc plasma gun to extract a pure carbon ion beam. The pure carbon ion beam is a new type of deposition system for diamond and other carbon materials. Our plasma device generates pure carbon plasma from solid-state carbon material without using a hydrocarbon gas such as methane gas, and the plasma does not contain any hydrogen. The ion saturation current of the discharge measured by a double probe is about 0.2 mA∕mm(2) at the peak of the pulse.

  8. Shunting arc plasma source for pure carbon ion beam.

    Science.gov (United States)

    Koguchi, H; Sakakita, H; Kiyama, S; Shimada, T; Sato, Y; Hirano, Y

    2012-02-01

    A plasma source is developed using a coaxial shunting arc plasma gun to extract a pure carbon ion beam. The pure carbon ion beam is a new type of deposition system for diamond and other carbon materials. Our plasma device generates pure carbon plasma from solid-state carbon material without using a hydrocarbon gas such as methane gas, and the plasma does not contain any hydrogen. The ion saturation current of the discharge measured by a double probe is about 0.2 mA∕mm(2) at the peak of the pulse. PMID:22380206

  9. New developments of 11C post-accelerated beams for hadron therapy and imaging

    Science.gov (United States)

    Augusto, R. S.; Mendonca, T. M.; Wenander, F.; Penescu, L.; Orecchia, R.; Parodi, K.; Ferrari, A.; Stora, T.

    2016-06-01

    Hadron therapy was first proposed in 1946 and is by now widespread throughout the world, as witnessed with the design and construction of the CNAO, HIT, PROSCAN and MedAustron treatment centres, among others. The clinical interest in hadron therapy lies in the fact that it delivers precision treatment of tumours, exploiting the characteristic shape (the Bragg peak) of the energy deposition in the tissues for charged hadrons. In particular, carbon ion therapy is found to be biologically more effective, with respect to protons, on certain types of tumours. Following an approach tested at NIRS in Japan [1], carbon ion therapy treatments based on 12C could be combined or fully replaced with 11C PET radioactive ions post-accelerated to the same energy. This approach allows providing a beam for treatment and, at the same time, to collect information on the 3D distributions of the implanted ions by PET imaging. The production of 11C ion beams can be performed using two methods. A first one is based on the production using compact PET cyclotrons with 10-20 MeV protons via 14N(p,α)11C reactions following an approach developed at the Lawrence Berkeley National Laboratory [2]. A second route exploits spallation reactions 19F(p,X)11C and 23Na(p,X)11C on a molten fluoride salt target using the ISOL (isotope separation on-line) technique [3]. This approach can be seriously envisaged at CERN-ISOLDE following recent progresses made on 11C+ production [4] and proven post-acceleration of pure 10C3/6+ beams in the REX-ISOLDE linac [5]. Part of the required components is operational in radioactive ion beam facilities or commercial medical PET cyclotrons. The driver could be a 70 MeV, 1.2 mA proton commercial cyclotron, which would lead to 8.1 × 10711C6+ per spill. This intensity is appropriate using 11C ions alone for both imaging and treatment. Here we report on the ongoing feasibility studies of such approach, using the Monte Carlo particle transport code FLUKA [6,7] to simulate

  10. Synthesis of carbon-11 labelled calcium channel antagonists

    International Nuclear Information System (INIS)

    A useful synthetic approach to carbon-11 labelled 1,4-dihydropyridines is described. Carbon-11 labelled calcium channel antagonists 11C-Nifedipine, 11C-Nisoldipine, 11C-nitrendipine and 11C-CF3-Nifedipine were synthesized by a modified Hantzsch method using protected carboxy functions. Deprotection of the carboxylic acids by alkaline hydrolysis followed by conversion into the corresponding potassium salts and subsequent methylation with 11CH3I produced the labelled compounds in very good chemical and radiochemical yields (94%). (author)

  11. Carbon beam dosimetry using VIP polymer gel and MRI

    DEFF Research Database (Denmark)

    Kantemiris, I; Petrokokkinos, L; Angelopoulos, A;

    2009-01-01

    VIP polymer gel dosimeter was used for Carbon ion beam dosimetry using a 150 MeV/n beam with 10 Gy plateau dose and a SOBP irradiation scheme with 5 Gy Bragg peak dose. The results show a decrease by 8 mm in the expected from Monte Carlo simulation range in water, suggesting that the dosimeter...

  12. Improvement of carbon fiber surface properties using electron beam irradiation

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Carbon fiber-reinforced advance composites have been used for struetural applications, mainly on account of their mechanical properties. The main factor for a good mechanical performance of carbon fiber-reinforced composite is the interfacial interaction between its components, which are carbon fiber and polymeric matrix. The aim of this study is to improve the surface properties of the carbon fiber using ionizing radiation from an electron beam to obtain better adhesion properties in the resultant composite. EB radiation was applied on the carbon fiber itself before preparing test specimens for the mechanical tests. Experimental results showed that EB irradiation improved the tensile strength of carbon fiber samples. The maximum value in tensile strength was reached using doses of about 250kGy. After breakage, the morphology aspect of the tensile specimens prepared with irradiated and non-irradiated carbon fibers were evaluated. SEM micrographs showed modifications on the carbon fiber surface.

  13. Studies and proposed changes to the RHIC p-Carbon polarimeters for the upcoming RUN-11

    Energy Technology Data Exchange (ETDEWEB)

    Makdisi, Y.; Alekseev, I.; Aschenauer, E.; Atoian, G.; Bazilevsky, A.; Gill, R.; Huang, H.; Morozov, B.; Svirida, D.; Yip, K.; Zelenski, A.

    2010-09-27

    The RHIC polarized proton complex utilizes polarimeters in each of the Blue and Yellow beams that measure the beam polarization through the p-Carbon elastic scattering process in the Coulomb Nuclear Interference kinematic region. This along with a Polarized Hydrogen Jet Target that utilizes the proton-proton elastic scattering process to first measure the analyzing power of the reaction and using the reverse process to measure the beam polarization. The latter is used to calibrate the p-Carbon polarimeters at the desired beam energy. In Run 9 RHIC ran with beams at center-of-mass energies of 200 and 500 GeV respectively. The higher beam intensities as well as the fact that the 250 GeV beam size is much smaller than that at 100 GeV resulted in significantly higher rates seen by the polarimeters and led to observed instability. In this paper, we will discuss the problems encountered and the tests that were carried out using the AGS as a proxy in an attempt to solve the problems and the path forward we took towards the upcoming polarized proton Run11.

  14. Studies and proposed changes to the RHIC p-Carbon polarimeters for the upcoming RUN-11

    International Nuclear Information System (INIS)

    The RHIC polarized proton complex utilizes polarimeters in each of the Blue and Yellow beams that measure the beam polarization through the p-Carbon elastic scattering process in the Coulomb Nuclear Interference kinematic region. This along with a Polarized Hydrogen Jet Target that utilizes the proton-proton elastic scattering process to first measure the analyzing power of the reaction and using the reverse process to measure the beam polarization. The latter is used to calibrate the p-Carbon polarimeters at the desired beam energy. In Run 9 RHIC ran with beams at center-of-mass energies of 200 and 500 GeV respectively. The higher beam intensities as well as the fact that the 250 GeV beam size is much smaller than that at 100 GeV resulted in significantly higher rates seen by the polarimeters and led to observed instability. In this paper, we will discuss the problems encountered and the tests that were carried out using the AGS as a proxy in an attempt to solve the problems and the path forward we took towards the upcoming polarized proton Run11.

  15. GHGT-11 - Integrated Carbon Risk Assessment (ICARAS)

    NARCIS (Netherlands)

    Wollenweber, J.; Busby, D.; Wessel-Berg, D.; Nepveu, M.; Bossie Codreanu, D.; Grimstad, A-A.; Sijacic, D.; Maurand, N.; Lothe, A.; Wahl, F.; Polak, S.; Boot, H.; Grøver, A.; Wildenborg, T.

    2013-01-01

    In this paper an integrated workflow is described for risk assessment within CCS. IFPEN, SINTEF and TNO joined forces to define a comprehensive and transparent risk assessment methodology. The tools developed in these institutes are thereby integrated. The workflow can be applied to proposed carbon

  16. Dose Response of Alanine Detectors Irradiated with Carbon Ion Beams

    DEFF Research Database (Denmark)

    Herrmann, Rochus; Jäkel, Oliver; Palmans, Hugo;

    2011-01-01

    . Methods: Alanine detectors have been irradiated with carbon ions with an energy range of 89-400 MeV/u. The relative effectiveness of alanine has been measured in this regime. Pristine and spread out Bragg peak depth-dose curves have been measured with alanine dosimeters. The track-structure based alanine......Purpose: The dose response of the alanine detector shows a dependence on particle energy and type, when irradiated with ion beams. The purpose of this study is to investigate the response behaviour of the alanine detector in clinical carbon ion beams and compare the results with model predictions...... of the detector geometry implemented in the Monte Carlo simulations....

  17. FIDDLING CARBON STRINGS WITH POLARIZED PROTON BEAMS.

    Energy Technology Data Exchange (ETDEWEB)

    HUANG, H.; KURITA, K.

    2006-05-01

    An innovative polarimeter based on proton carbon elastic scattering in the Coulomb Nuclear Interference (CNI) region was first tested in the Brookhaven AGS successfully. CNI Polarimeters were then installed in the AGS and both RHIC rings. The polarimeter consists of ultra-thin carbon targets and silicon strip detectors. The waveform digitizers are used for signal readout, which allows deadtime-less data processing on the fly. Polarimeters are crucial instrumentation for the RHIC spin physics program. This paper summarizes the polarimeter design issues and operation results.

  18. Biological effect of carbon beams on cultured human cells

    International Nuclear Information System (INIS)

    This study was performed to determine the biological effect of carbon beams on 13 human tumor cells, in comparison with 200 KVp X-rays. Carbon beams were generated by the Riken Ring Cyclotron. The RBE (relative biological effectiveness) values were distributed from 1.46 to 2.20 for LET of 20 keV/μm, and 2.29-3.54 for 80 keV/μm. The RBEs were increased in all cell lines as the LET of carbon beams was increased from 20 to 80 keV/μm. There was no significant difference in radiosensitivity between cells from adenocarcinoma and those from squamous cell carcinoma. The relationship between the radiosensitivity of cells to X-rays and RBE was analyzed, but no significant correlation was suggested. Several survival curves of 20-40 keV/μm carbon beam irradiation showed the initial shoulders and the recovery ratios between two split doses were determined. Recovery was observed for LET of 2O keV/μm but not for that of 40 keV/μm. Furthermore, recovery ratios were 1.0-1.8, smaller than those for X-rays (1.5-2.4). (author)

  19. Design Study of a Superconducting Gantry for Carbon Beam Therapy

    CERN Document Server

    Kim, J

    2016-01-01

    This paper describes the design study of a gantry for a carbon beam. The designed gantry is compact such that its size is comparable to the size of the proton gantry. This is possible by introducing superconducting double helical coils for dipole magnets. The gantry optics is designed in such a way that it provides rotation-invariant optics and variable beam size as well as point-to-parallel scanning of a beam. For large-aperture magnet, three-dimensional magnetic field distribution is obtained by invoking a computer code, and a number of particles are tracked by integrating equations of motion numerically together with three-dimensional interpolation. The beam-shape distortion due to the fringe field is reduced to an acceptable level by optimizing the coil windings with the help of genetic algorithm. Higher-order transfer coefficients are calculated and shown to be reduced greatly with appropriate optimization of the coil windings.

  20. Track detector based dosimetry for therapeutic carbon beams

    CERN Document Server

    Osinga, J -M; Brabcová, K Pachnerová; Akselrod, M S; Jäkel, O; Davídková, M; Greilich, S

    2013-01-01

    The ability of plastic and fluorescent nuclear track detectors (PNTDs and FNTDs) to measure fluence and the linear energy transfer (LET) of clinical carbon ion beams was investigated. We employed coincident measurements with both systems and registered the results at the level of single tracks. Irradiations were performed in the entrance channel of the monoenergetic carbon ion beam covering the therapeutically useful energy range from 80 to 425 MeV/u. About 99 % of all primary particle tracks detected by both detectors were successfully matched, while 1 % of the particles were only detected by the FNTDs because of their superior spatial resolution. We conclude that both PNTDs and FNTDs are suitable for clinical carbon beam dosimetry with a detection efficiency of at least 98.82 % and 99.83 % respectively, if irradiations are performed with low fluence in the entrance channel of the ion beam. Additionally, a relationship between the mean LET as determined with PNTDs and the mean fluorescence amplitude of the p...

  1. Beams '96. Proceedings of the 11th international conference on high power particle beams. Vol. II

    International Nuclear Information System (INIS)

    The scientific programme of the conference carved the physics and technology of intense beams of charged particles, from basic experimental and theoretical problems of beam generation, transport and interaction with various media, up to beam and pulsed power applications in science and in industry. The breakdown of the papers by main topical groups is as follows: radiation sources, Z-pinches, accelerate related topics, astrophysics, ICF, ION Beam Physics, ION DIODES, ION RINGS, Beam plasma systems, diagnostic and others. This volumes contains 160 contributions, out which 133 have been input to INIS

  2. Beams '96. Proceedings of the 11th international conference on high power particle beams. Vol. I

    International Nuclear Information System (INIS)

    The Proceedings contain the full texts of 60 orals and 243 poster papers presented at the Conference. The scientific programme of the conference covered the physics and technology of intense beams of charged particles, from basic experimental and theoretical problems of beam generation, transport and interaction with various media, up to beam and pulsed power applications in science and in industry. The breakdown of the papers by main topical groups is as follows: electron beams, beam-plasma systems, high-power microwaves (62), imploding liners, z-pinches, plasma foci (53), pulsed power technology and its applications (53), ion beams and ICF (41), industrial applications of electron and ion beams (36), radiation sources (23), diagnostics (14), and others (21). (J.U.)

  3. Characterization of a radioactive {sup 11}C beam by means of the associated particle technique

    Energy Technology Data Exchange (ETDEWEB)

    Varela, A.; Policroniades, R.; Murillo, G.; Moreno, E. [ININ, Laboratorio del Acelerador Tandem, Carretera Mexico-Toluca s/n, Ocoyoacac 52750, Estado de Mexico (Mexico); Huerta, A.; Chavez, E.; Ortiz, M. E.; Barron, L.; Curiel, Q. [UNAM, Instituto de Fisica, Circuito Exterior, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Aguilar, C.; Coello, E. A.; Juarez, M. A.; Martinez, J. N. [UNAM, Facultad de Ciencias, Circuito Exterior, Ciudad Universitaria, 04510 Mexico D. F. (Mexico)

    2010-02-15

    This paper describes the results obtained for the production and characterization of a radioactive {sup 11}C beam, by means of the in flight technique and the tandem laboratory of the National Institute of Nuclear Research, Mexico. The {sup 11}C production technique described here, uses the well known associated particle technique with the reaction {sup 2}H({sup 10}B, {sup 11}C)n, in order to obtain a bi univocal correspondence between the radioactive {sup 11}C particles and the associated neutrons. A discussion concerning the possible use of this {sup 11}C beam in the study of the elastic scattering of protons is introduced. (Author)

  4. Radiation dose estimates for carbon-11-labelled PET tracers

    International Nuclear Information System (INIS)

    Introduction: Carbon-11-labelled positron emission tomography (PET) tracers commonly used in biomedical research expose subjects to ionising radiation. Dosimetry is the measurement of radiation dose, but also commonly refers to the estimation of health risk associated with ionising radiation. This review describes radiation dosimetry of carbon-11-labelled molecules in the context of current PET research and the most widely used regulatory guidelines. Methods: A MEDLINE literature search returned 42 articles; 32 of these were based on human PET data dealing with radiation dosimetry of carbon-11 molecules. Radiation burden expressed as effective dose and maximum absorbed organ dose was compared between tracers. Results: All but one of the carbon-11-labelled PET tracers have an effective dose under 9 μSv/MBq, with a mean of 5.9 μSv/MBq. Data show that serial PET scans in a single subject are feasible for the majority of radiotracers. Conclusion: Although differing in approach, the two most widely used regulatory frameworks (those in the USA and the EU) do not differ substantially with regard to the maximum allowable injected activity per PET study. The predictive validity of animal dosimetry models is critically discussed in relation to human dosimetry. Finally, empirical PET data are related to human dose estimates based on homogenous distribution, generic models and maximum cumulated activities. Despite the contribution of these models to general risk estimation, human dosimetry studies are recommended where continued use of a new PET tracer is foreseen.

  5. One carbon metabolism in SAR11 pelagic marine bacteria.

    Directory of Open Access Journals (Sweden)

    Jing Sun

    Full Text Available The SAR11 Alphaproteobacteria are the most abundant heterotrophs in the oceans and are believed to play a major role in mineralizing marine dissolved organic carbon. Their genomes are among the smallest known for free-living heterotrophic cells, raising questions about how they successfully utilize complex organic matter with a limited metabolic repertoire. Here we show that conserved genes in SAR11 subgroup Ia (Candidatus Pelagibacter ubique genomes encode pathways for the oxidation of a variety of one-carbon compounds and methyl functional groups from methylated compounds. These pathways were predicted to produce energy by tetrahydrofolate (THF-mediated oxidation, but not to support the net assimilation of biomass from C1 compounds. Measurements of cellular ATP content and the oxidation of (14C-labeled compounds to (14CO(2 indicated that methanol, formaldehyde, methylamine, and methyl groups from glycine betaine (GBT, trimethylamine (TMA, trimethylamine N-oxide (TMAO, and dimethylsulfoniopropionate (DMSP were oxidized by axenic cultures of the SAR11 strain Ca. P. ubique HTCC1062. Analyses of metagenomic data showed that genes for C1 metabolism occur at a high frequency in natural SAR11 populations. In short term incubations, natural communities of Sargasso Sea microbial plankton expressed a potential for the oxidation of (14C-labeled formate, formaldehyde, methanol and TMAO that was similar to cultured SAR11 cells and, like cultured SAR11 cells, incorporated a much larger percentage of pyruvate and glucose (27-35% than of C1 compounds (2-6% into biomass. Collectively, these genomic, cellular and environmental data show a surprising capacity for demethylation and C1 oxidation in SAR11 cultures and in natural microbial communities dominated by SAR11, and support the conclusion that C1 oxidation might be a significant conduit by which dissolved organic carbon is recycled to CO(2 in the upper ocean.

  6. Practical biological spread-out Bragg peak design of carbon beam

    OpenAIRE

    Kim, Chang Hyeuk; Lee, Hwa-Ryun; Chang, Seduk; Jang, Hong Suk; Kim, Jeong Hwan; Park, Dong Wook; Hwang, Won Taek; Yang, Tea-Keun

    2015-01-01

    The carbon beams show more advantages on the biological properties compared with proton beams in radiation therapy. The carbon beam shows high linear energy transfer (LET) to medium and it increases the relative biological effectiveness (RBE). To design spread-out Bragg peak (SOBP) of biological dose using carbon beam, a practical method was purposed by using the linear-quadratic (LQ) model and Geant4 based Monte Carlo simulation code. The various Bragg peak profiles and LET was calculated fo...

  7. Response of SOI image sensor to therapeutic carbon ion beam

    CERN Document Server

    Matsumura, Akihiko

    2015-01-01

    Carbon ion radiotherapy is known as a less invasive cancer treatment. The radiation quality is an important parameter to evaluate the biological effect and the clinical dose from the measured physical dose. The performance of SOPHIAS detector, which is the SOI image sensor having a wide dynamic range and large active area, was tested by using therapeutic carbon ion beam at Gunma University Heavy Ion Medical Center (GHMC). It was shown that the primary carbon and secondary particles can be distinguishable by SOPHIAS detector. On the other hand, a LET dependence was observed especially at the high LET region. This phenomenon will be studied by using the device simulator together with Monte Carlo simulation.

  8. Ethanolic Carbon-11 Chemistry: the Introduction of Green Radiochemistry

    Science.gov (United States)

    Shao, Xia; Fawaz, Maria V.; Jang, Keunsam; Scott, Peter J. H.

    2014-01-01

    The principles of green chemistry have been applied to a radiochemistry setting. Eleven carbon-11 labeled radiopharmaceuticals have been prepared using ethanol as the only organic solvent throughout the entire manufacturing process. The removal of all other organic solvents from the process simplifies production and quality control (QC) testing, moving our PET Center towards the first example of a green radiochemistry laboratory. All radiopharmaceutical doses prepared are suitable for clinical use. PMID:24631743

  9. Ethanolic carbon-11 chemistry: the introduction of green radiochemistry.

    Science.gov (United States)

    Shao, Xia; Fawaz, Maria V; Jang, Keunsam; Scott, Peter J H

    2014-07-01

    The principles of green chemistry have been applied to a radiochemistry setting. Eleven carbon-11 labeled radiopharmaceuticals have been prepared using ethanol as the only organic solvent throughout the entire manufacturing process. The removal of all other organic solvents from the process simplifies production and quality control (QC) testing, moving our PET Center towards the first example of a green radiochemistry laboratory. All radiopharmaceutical doses prepared are suitable for clinical use.

  10. Carbon dust particles in a beam-plasma discharge

    Science.gov (United States)

    Koval, O. A.; Vizgalov, V.; Shalpegin, A. V.

    2016-09-01

    This paper focuses on dynamics of micro-sized carbon dust grains in beam-plasma discharge (BPD) plasmas. It was demonstrated that injected dust particles can be captured and transported along the discharge. Longitudinal average velocity of the particles in the central area of the plasma column was 17 m/sec, and 2 m/sec in the periphery. Dust injection caused a decrease of emission intensity of metastable nitrogen molecular ion. This effect is suggested for a spectroscopy method for particles’ potential measurements. Five-micron radius carbon dust grains obtained potential above 500 V in the experiments on PR-2 installation, proving the feasibility of BPDs for the charging of fine dust particles up to high potential values, unattainable in similar plasma conditions.

  11. Electron beam influence on the carbon contamination of electron irradiated hydroxyapatite thin films

    International Nuclear Information System (INIS)

    Highlights: • Carbon contamination mechanisms of electron-beam-irradiated hydroxyapatite. • Atomic force microscopy phase imaging used to detect carbon contamination. • Carbon contamination dependence on electron energy, irradiation time, beam current. • Simulation of backscattered electrons confirms the experimental results. - Abstract: Electron beam irradiation which is considered a reliable method for tailoring the surface charge of hydroxyapatite is hindered by carbon contamination. Separating the effects of the carbon contamination from those of irradiation-induced trapped charge is important for a wide range of biological applications. In this work we focus on the understanding of the electron-beam-induced carbon contamination with special emphasis on the influence of the electron irradiation parameters on this phenomenon. Phase imaging in atomic force microscopy is used to evaluate the influence of electron energy, beam current and irradiation time on the shape and size of the resulted contamination patterns. Different processes involved in the carbon contamination of hydroxyapatite are discussed

  12. Synthesis of colchicine and isocolchicine labelled with carbon-11 or carbon-13

    Energy Technology Data Exchange (ETDEWEB)

    Kothari, P.J.; Finn, R.D.; Larson, S.M. [Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    1995-06-01

    The syntheses of isotopically labelled (-)-10-[{sup 11}C/{sup 13}C]-colchicine and (-)-9-[{sup 11}C/{sup 13}C]-isocolchicine have been achieved from the reaction of (-)desmethylcolchicine with [{sup 11}C/{sup 13}C]-iodomethane. The radiolabelled compounds, (-)-10-[{sup 11}C]-colchicine ({sup 11}C-n-colchicine) and (-)-9-[{sup 11}C]-isocolchicine ({sup 11}C-i-colchicine), were isolated by reversed phase HPLC. The total synthesis time was approximately 60 minutes for both radiolabelled compounds with an average specific activity of 240 mCi/{mu}mol calculated to EOB. Utilizing a similar synthetic strategy, we also reported the synthesis of milligram quantities of the carbon-13 enriched compounds and the magnetic resonance signal assignment for (-)-9-[{sup 13}C] isocolchicine. (Author).

  13. Biological intercomparison using gut crypt survivals for proton and carbon-ion beams

    International Nuclear Information System (INIS)

    Charged particle therapy depends on biological information for the dose prescription. Relative biological effectiveness or RBE for this requirement could basically be provided by experimental data. As RBE values of protons and carbon ions depend on several factors such as cell/tissue type, biological endpoint, dose and fractionation schedule, a single RBE value could not deal with all different radiosensitivities. However, any biological model with accurate reproducibility is useful for comparing biological effectiveness between different facilities. We used mouse gut crypt survivals as endpoint, and compared the cell killing efficiency of proton beams at three Japanese facilities. Three Linac X-ray machines with 4 and 6 MeV were used as reference beams, and there was only a small variation (coefficient of variance<2%) in biological effectiveness among them. The RBE values of protons relative to Linac X-rays ranged from 1.0 to 1.11 at the middle of a 6-cm SOBP (spread-out Bragg peak) and from 0.96 to 1.01 at the entrance plateau. The coefficient of variance for protons ranged between 4.0 and 5.1%. The biological comparison of carbon ions showed fairly good agreement in that the difference in biological effectiveness between National Institute of Radiological Sciences (NIRS)/ Heavy Ion Medical Accelerator in Chiba (HIMAC) and Gesellschaft fur Schwerionenforschung (GSI)/Heavy Ion Synchrotron (SIS) was 1% for three positions within the 6-cm SOBP. The coefficient of variance was <1.7, <0.6 and <1.6% for proximal, middle and distal SOBP, respectively. We conclude that the inter-institutional variation of biological effectiveness is smaller for carbon ions than protons, and that beam-spreading methods of carbon ions do not critically influence gut crypt survival. (author)

  14. Run05 Proton Beam Polarization Measurements by pC-Polarimeter (ver. 1.1)

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa,I.; Alekseev, I.; Bazilevsky, A.; Bravar, A.; Bunce, G.; Dhawan, S.; Eyser, K.O.; Gill, R.; Haeberli, W.; Huang, H.; Makdisi, Y.; Nass, A.; Okada, H.; Stephenson, E.; Svirida, D.N.; Wise, T.; Wood, J.; Yip, K.; Zelenski, A.

    2008-07-01

    The polarization of the proton beams [1, 2] at the Relativistic Heavy Ion Collider (RHIC)[3] RHIC ring. The H-Jet polarimeter is located at the collision point allowing measurements of absolute normalization is provided by the hydrogen polarimeter, which measures over 1 {approx} 2 another measurement rather than measuring the absolute polarization. both beams. Two identical pC-polarimeters are equipped in the yellow and blue rings, where carbon ribbon target, providing fast feedback to beam operations and experiments. The days to obtain {approx} 5% statistical uncertainty (in Run05). Thus, the operation of the carbon is measured using both an atomic beam source hydrogen gas jet (H-Jet)[4, 5] and proton-carbon polarimeters was focused on better control of relative stability between one measurement to statistical accuracy within 20 to 30 seconds using an ultra-thin (typically 6 {approx} 8 {micro}g/cm{sup 2}) the rings are separated. The pC-polarimeter measures relative polarization to a few percent.

  15. SU-E-J-144: Low Activity Studies of Carbon 11 Activation Via GATE Monte Carlo

    International Nuclear Information System (INIS)

    Purpose: To investigate the behavior of a Monte Carlo simulation code with low levels of activity (∼1,000Bq). Such activity levels are expected from phantoms and patients activated via a proton therapy beam. Methods: Three different ranges for a therapeutic proton radiation beam were examined in a Monte Carlo simulation code: 13.5, 17.0 and 21.0cm. For each range, the decay of an equivalent length11C source and additional sources of length plus or minus one cm was studied in a benchmark PET simulation for activities of 1000, 2000 and 3000Bq. The ranges were chosen to coincide with a previous activation study, and the activities were chosen to coincide with the approximate level of isotope creation expected in a phantom or patient irradiated by a therapeutic proton beam. The GATE 7.0 simulation was completed on a cluster node, running Scientific Linux Carbon 6 (Red Hat©). The resulting Monte Carlo data were investigated with the ROOT (CERN) analysis tool. The half-life of11C was extracted via a histogram fit to the number of simulated PET events vs. time. Results: The average slope of the deviation of the extracted carbon half life from the expected/nominal value vs. activity showed a generally positive value. This was unexpected, as the deviation should, in principal, decrease with increased activity and lower statistical uncertainty. Conclusion: For activity levels on the order of 1,000Bq, the behavior of a benchmark PET test was somewhat unexpected. It is important to be aware of the limitations of low activity PET images, and low activity Monte Carlo simulations. This work was funded in part by the Philips corporation

  16. Atomic Funnel Composed of an HE11-Mode Output Hollow Beam

    Institute of Scientific and Technical Information of China (English)

    倪赟; 刘南春; 印建平

    2003-01-01

    Using exact solutions of Maxwell equations based on the vector model, we calculate the diffracted near- and far-field distributions of the HEi1-mode output beam from a micron-sized hollow optical fibre under the Fresnel approximation, and compare the differences between the HE11- and LP01-mode output beams. Our study shows that it is unsuitable to calculate the diffracted near-field distribution of the hollow fibre by using weakly waveguiding approximation, and the near- and far-field intensity distributions of the HE11-mode output beam are doughnut-like, which can be used to form a simple atomic funnel as it is blue-detuned.

  17. CERN Accelerator School: Intensity Limitations in Particle Beams | 2-11 November

    CERN Multimedia

    2015-01-01

    Registration is now open for the CERN Accelerator School’s specialised course on Intensity Limitations in Particle Beams, to be held at CERN between 2 and 11 November 2015.   This course will mainly be of interest to staff in accelerator laboratories, university departments and companies manufacturing accelerator equipment. Many accelerators and storage rings, whether intended for particle physics experiments, synchrotron light sources or industrial applications, require beams of high brightness and the highest possible intensities. A good understanding of the possible limitations is required to achieve the desired performance. The programme for this course will cover the interaction of beams with their surroundings, with other beams and further collective effects. Lectures on the effects and possible mitigations will be complemented by tutorials. Further information can be found at: http://cas.web.cern.ch/cas/Intensity-Limitations-2015/IL-advert.html   http:/...

  18. Enhancement of neutral beam deposition in hydrogen discharge using carbon pellet injection in LHD

    International Nuclear Information System (INIS)

    The central ion temperature in the large helical device (LHD), as measured by charge-exchange recombination spectroscopy, has been improved to a record 5.6 keV by combining 21 MW of neutral beam heating with the injection of a carbon pellet. The intensity of the neutral beam emission of the hydrogen Balmer line (Hα: n=3 → 2) was observed to weaken along the beam injection axis following the carbon pellet injection due to the increased beam attenuation. The beam-emission intensity was reconstructed by calculating the density distribution, and the beam-stopping coefficients, along a beam injection axis and was found to fit well to the measured beam-emission for a mixed hydrogen and carbon target plasma. The dynamics of the neutral beam deposition power and the carbon fraction were estimated from the beam-emission measurements using data from ADAS. We conclude that the beam deposition power in a carbon pellet discharge is enhanced over that of a pure hydrogen discharge. (author)

  19. Kinetics of ion beam deposition of carbon at room temperature

    International Nuclear Information System (INIS)

    Growth rates of carbon films grown by ion beam deposition using methane gas were measured in situ as a function of deposition conditions. The methane pressure dependence of the growth rate was used to measure the cross-section for charge exchange. Variations in deposition rate per incident energetic particle found for each ion energy were related to ion current density. It was found that rates of growth per incident energetic specie were (i) largest for the smallest current densities, (ii) decreased monotonically with increasing current density, and (iii) were consistently larger than can be explained by deposition directly from the energetic flux alone. These observations were interpreted in terms of irradiation-induced surface interactions which promote chemisorption of methane physisorbed from the ambient atmosphere. (orig.)

  20. Ethanolic carbon-11 chemistry: The introduction of green radiochemistry

    International Nuclear Information System (INIS)

    The principles of green chemistry have been applied to a radiochemistry setting. Eleven carbon-11 labeled radiopharmaceuticals have been prepared using ethanol as the only organic solvent throughout the entire manufacturing process. The removal of all other organic solvents from the process simplifies production and quality control (QC) testing, moving our PET Center towards the first example of a green radiochemistry laboratory. All radiopharmaceutical doses prepared are suitable for clinical use. - Highlights: • We report application of the principles of green chemistry to a radiochemistry setting. • Radiopharmaceuticals are prepared using ethanol as the only organic solvent. • Green radiochemistry simplifies production and QC in busy clinical production laboratories. • Residual solvent analysis can be relegated to a quarterly or annual QC test

  1. Electron Cloud in Steel Beam Pipe vs Titanium Nitride Coated and Amorphous Carbon Coated Beam Pipes in Fermilab's Main Injector

    Energy Technology Data Exchange (ETDEWEB)

    Backfish, Michael

    2013-04-01

    This paper documents the use of four retarding field analyzers (RFAs) to measure electron cloud signals created in Fermilab’s Main Injector during 120 GeV operations. The first data set was taken from September 11, 2009 to July 4, 2010. This data set is used to compare two different types of beam pipe that were installed in the accelerator. Two RFAs were installed in a normal steel beam pipe like the rest of the Main Injector while another two were installed in a one meter section of beam pipe that was coated on the inside with titanium nitride (TiN). A second data run started on August 23, 2010 and ended on January 10, 2011 when Main Injector beam intensities were reduced thus eliminating the electron cloud. This second run uses the same RFA setup but the TiN coated beam pipe was replaced by a one meter section coated with amorphous carbon (aC). This section of beam pipe was provided by CERN in an effort to better understand how an aC coating will perform over time in an accelerator. The research consists of three basic parts: (a) continuously monitoring the conditioning of the three different types of beam pipe over both time and absorbed electrons (b) measurement of the characteristics of the surrounding magnetic fields in the Main Injector in order to better relate actual data observed in the Main Injector with that of simulations (c) measurement of the energy spectrum of the electron cloud signals using retarding field analyzers in all three types of beam pipe.

  2. Nuclear reactions with 11C and 14O radioactive ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Fanqing

    2004-12-09

    Radioactive ion beams (RIBs) have been shown to be a useful tool for studying proton-rich nuclides near and beyond the proton dripline and for evaluating nuclear models. To take full advantage of RIBs, Elastic Resonance Scattering in Inverse Kinematics with Thick Targets (ERSIKTT), has proven to be a reliable experimental tool for investigations of proton unbound nuclei. Following several years of effort, Berkeley Experiments with Accelerated Radioactive Species (BEARS), a RIBs capability, has been developed at the Lawrence Berkeley National Laboratory's 88-Inch Cyclotron. The current BEARS provides two RIBs: a 11C beam of up to 2x108 pps intensity on target and an 14O beam of up to 3x104 pps intensity. While the development of the 11C beam has been relatively easy, a number of challenges had to be overcome to obtain the 14O beam. The excellent 11C beam has been used to investigate several reactions. The first was the 197Au(11C,xn)208-xnAt reaction, which was used to measure excitation functions for the 4n to 8n exit channels. The measured cross sections were generally predicted quite well using the fusion-evaporation code HIVAP. Possible errors in the branching ratios of ?? decays from At isotopes as well as the presence of incomplete fusion reactions probably contribute to specific overpredictions. 15F has been investigated by the p(14O,p)14O reaction with the ERSIKTT technology. Several 14O+p runs have been performed. Excellent energy calibration was obtained using resonances from the p(14N,p)14N reaction in inverse kinematics, and comparing the results to those obtained earlier with normal kinematics. The differences between 14N+p and 14O+p in the stopping power function have been evaluated for better energy calibration. After careful calibration, the energy levels of 15F were fitted with an R-matrix calculation. Spins and parities were assigned to the two observed resonances. This new measurement of the 15F ground state supports the disappearance of the Z

  3. Nuclear reactions with 11C and 14O radioactive ion beams

    International Nuclear Information System (INIS)

    Radioactive ion beams (RIBs) have been shown to be a useful tool for studying proton-rich nuclides near and beyond the proton dripline and for evaluating nuclear models. To take full advantage of RIBs, Elastic Resonance Scattering in Inverse Kinematics with Thick Targets (ERSIKTT), has proven to be a reliable experimental tool for investigations of proton unbound nuclei. Following several years of effort, Berkeley Experiments with Accelerated Radioactive Species (BEARS), a RIBs capability, has been developed at the Lawrence Berkeley National Laboratory's 88-Inch Cyclotron. The current BEARS provides two RIBs: a 11C beam of up to 2x108 pps intensity on target and an 14O beam of up to 3x104 pps intensity. While the development of the 11C beam has been relatively easy, a number of challenges had to be overcome to obtain the 14O beam. The excellent 11C beam has been used to investigate several reactions. The first was the 197Au(11C,xn)208-xnAt reaction, which was used to measure excitation functions for the 4n to 8n exit channels. The measured cross sections were generally predicted quite well using the fusion-evaporation code HIVAP. Possible errors in the branching ratios of ?? decays from At isotopes as well as the presence of incomplete fusion reactions probably contribute to specific overpredictions. 15F has been investigated by the p(14O,p)14O reaction with the ERSIKTT technology. Several 14O+p runs have been performed. Excellent energy calibration was obtained using resonances from the p(14N,p)14N reaction in inverse kinematics, and comparing the results to those obtained earlier with normal kinematics. The differences between 14N+p and 14O+p in the stopping power function have been evaluated for better energy calibration. After careful calibration, the energy levels of 15F were fitted with an R-matrix calculation. Spins and parities were assigned to the two observed resonances. This new measurement of the 15F ground state supports the disappearance of the Z = 8

  4. Reactions with a 10Be beam to study the one-neutron halo nucleus 11Be

    Science.gov (United States)

    Jones, K. L.

    2016-07-01

    Halo nuclei are excellent examples of few-body systems consisting of a core and weakly-bound halo nucleons. Where there is only one nucleon in the halo, as in 11Be, the many-body problem can be reduced to a two-body problem. The contribution of the 1s1/2 orbital to the ground state configuration in 11Be, characterized by the spectroscopic factor, S, has been extracted from direct reaction data by many groups over the past five decades with discrepant results. An experiment was performed at the Holifield Radioactive Ion Beam Facility using a 10Be primary beam at four different energies with the goal of resolving the discrepancy through a consistent analysis of elastic, inelastic, and transfer channels. Faddeev-type calculations, released after the publication of the experimental results, show that dynamic core excitation in the transfer process can lead to reduced differential cross sections at higher beam energies. This reduction would lead to the extraction of decreasing values of S with increasing beam energy. A 10Be(d,p) measurement at Ed greater than 25 MeV is necessary to investigate the effects of core excitation in the reaction.

  5. Reactions with a 10Be beam to study the one-neutron halo nucleus 11Be

    CERN Document Server

    Jones, K L

    2016-01-01

    Halo nuclei are excellent examples of few-body systems consisting of a core and weakly-bound halo nucleons. Where there is only one nucleon in the halo, as in 11Be, the many-body problem can be reduced to a two-body problem. The contribution of the 1s1/2 orbital to the ground state configuration in 11Be, characterized by the spectroscopic factor, S, has been extracted from direct reaction data by many groups over the past five decades with discrepant results. An experiment was performed at the Holifield Radioactive Ion Beam Facility using a 10Be primary beam at four different energies with the goal of resolving the discrepancy through a consistent analysis of elastic, inelastic, and transfer channels. Faddeev-type calculations, released after the publication of the experimental results, show that dynamic core excitation in the transfer process can lead to reduced differential cross sections at higher beam energies. This reduction would lead to the extraction of decreasing values of S with increasing beam ener...

  6. Interaction of the CERN Large Hadron Collider (LHC) Beam with Carbon Collimators

    CERN Document Server

    Schmidt, R; Hoffmann, Dieter H H; Kadi, Y; Shutov, A; Piriz, AR

    2006-01-01

    The LHC will operate at an energy of 7 TeV with a luminosity of 1034cm-2s-1. This requires two beams, each with 2808 bunches. The energy stored in each beam of 362 MJ. In a previous paper the mechanisms causing equipment damage in case of a failure of the machine protection system was discussed, assuming that the entire beam is deflected into a copper target [1, 2]. Another failure scenario is the deflection of beam into carbon material. Carbon collimators and beam absorbers are installed in many locations around the LHC to diffuse or absorb beam losses. Since the collimator jaws are close to the beam, it is very likely that they are hit first when the beam is accidentally deflected. Here we present the results of two-dimensional hydrodynamic simulations of the heating of a solid carbon cylinder irradiated by the LHC beam with nominal parameters, carried out using the BIG-2 computer code [3] while the energy loss of the 7 TeV protons in carbon is calculated using the well known FLUKA code [4]. Our calculation...

  7. Assessment of adhesive setting time in reinforced concrete beams strengthened with carbon fibre reinforced polymer laminates

    International Nuclear Information System (INIS)

    Highlights: ► This study investigated the effect of adhesive setting time on the modal parameters. ► Modal parameters recommend the 18th day as the maturity age of the adhesive. ► Static data recommend 7th day as the maturity age of the adhesive. ► Setting time affects the modal parameters as tool for assessment repaired structures. ► Carrying the modal parameters after 1st day results in 55% loss of the actual improvement. -- Abstract: The strengthened effectiveness and the performance capacity of repaired Reinforced Concrete (RC) structures with Carbon Fibre Reinforced Polymer (CFRP) sheets is dependent on the properties of the adhesive interface layer. Adhesive material requires a specific setting time to achieve the maximum design capacity. Adhesive producer provides technical data which demonstrates the increase with time of the capacity, up to the maximum. The aim of this study is to investigate the effect of the adhesive setting time on the modal parameters as an indication of the effectiveness of CFRP on repaired RC beams. Firstly, datum modal parameters were determined on the undamaged beam and subsequently the parameters were obtained when damaged was induced on the RC beam by application of load until the appearance of the first crack. Finally, the RC beam is repaired with externally bonded CFRP sheets, and modal parameters are once again applied after 0.5, 1, 2, 3, 5, 8, 11, 15 and 18 days. The comparison is made with the data based on half day results in order to monitor the change in the modal parameters corresponding to the adhesive setting time. The modal parameters where used as indicators for the effectiveness of CFRP are affected by the adhesive time as shown in this study. Results are compared with the adhesive technical data provided by the adhesive producer.

  8. Carbon-11-methionine positron emission tomography imaging of chordoma

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hong [Department of Medical Imaging, National Institute of Radiological Sciences, Chiba (Japan); Department of Medical Imaging, Research Center Hospital for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1, Anagawa, Inage-ku, 263-8555, Chiba (Japan); Yoshikawa, Kyosan; Tamura, Katsumi; Sagou, Kenji; Kandatsu, Susumu [Clinical Diagnosis Section, National Institute of Radiological Sciences, Chiba (Japan); Tian, Mei; Suhara, Tetsuya; Suzuki, Kazutoshi; Tanada, Shuji [Department of Medical Imaging, National Institute of Radiological Sciences, Chiba (Japan); Tsujii, Hirohiko [Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Chiba (Japan)

    2004-09-01

    Chordoma is a rare malignant bone tumor that arises from notochord remnants. This is the first trial to investigate the utility of {sup 11}C-methionine (MET) positron emission tomography (PET) in the imaging of chordoma before and after carbon-ion radiotherapy (CIRT). Fifteen patients with chordoma were investigated with MET-PET before and after CIRT and the findings analyzed visually and quantitatively. Tumor MET uptake was evaluated by tumor-to-nontumor ratio (T/N ratio). In 12 (80%) patients chordoma was clearly visible in the baseline MET-PET study with a mean T/N ratio of 3.3{+-}1.7. The MET uptake decreased significantly to 2.3{+-}1.4 after CIRT (P<0.05). A significant reduction in tumor MET uptake of 24% was observed after CIRT. Fourteen (93%) patients showed no local recurrence after CIRT with a median follow-up time of 20 months. This study has demonstrated that MET-PET is feasible for imaging of chordoma. MET-PET could provide important tumor metabolic information for the therapeutic monitoring of chordoma after CIRT. (orig.)

  9. Ion beam deposition of amorphous carbon films with diamond like properties

    Science.gov (United States)

    Angus, John C.; Mirtich, Michael J.; Wintucky, Edwin G.

    1982-01-01

    Carbon films were deposited on silicon, quartz, and potassium bromide substrates from an ion beam. Growth rates were approximately 0.3 micron/hour. The films were featureless and amorphous and contained only carbon and hydrogen in significant amounts. The density and carbon/hydrogen ratio indicate the film is a hydrogen deficient polymer. One possible structure, consistent with the data, is a random network of methylene linkages and tetrahedrally coordinated carbon atoms.

  10. Study of Nuclear Reactions with 11C and 15O Radioactive Ion Beams

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dongwon [Univ. of California, Berkeley, CA (United States)

    2007-05-14

    Nuclear reaction study with radioactive ion beams is one of the most exciting research topics in modern nuclear physics. The development of radioactive ion beams has allowed nuclear scientists and engineers to explore many unknown exotic nuclei far from the valley of nuclear stability, and to further our understanding of the evolution of the universe. The recently developed radioactive ion beam facility at the Lawrence Berkeley National Laboratory's 88-inch cyclotron is denoted as BEARS and provides 11C, 14O and 15O radioactive ion beams of high quality. These moderate to high intensity, proton-rich radioactive ion beams have been used to explore the properties of unstable nuclei such as 12N and 15F. In this work, the proton capture reaction on 11C has been evaluated via the indirect d(11C, 12N)n transfer reaction using the inverse kinematics method coupled with the Asymptotic Normalization Coefficient (ANC) theoretical approach. The total effective 12N → 11C+p ANC is found to be (C eff12N = 1.83 ± 0.27 fm-1. With the high 11C beam intensity available, our experiment showed excellent agreement with theoretical predictions and previous experimental studies. This study also indirectly confirmed that the 11C(p,γ) reaction is a key step in producing CNO nuclei in supermassive low-metallicity stars, bypassing the slow triple alpha process. The newly developed 15O radioactive ion beam at BEARS was used to study the poorly known level widths of 16F via the p(15O,15O)p reaction. Among the nuclei in the A=16, T=1 isobaric triad, many states in 16N and 16O have been well established, but less has been reported on 16F. Four states of 16F below 1 MeV have been identified experimentally: 0-, 1

  11. Emulsion Cloud Chamber technique to measure the fragmentation of a high-energy carbon beam

    OpenAIRE

    De Lellis, G.; Buontempo., S; Di Capua, F.; Marotta, A; Migliozzi, P.; Petukhov, Y.; Pistillo, C; Russo, A; Lavina, L. Scotto; Strolin, P.(Dipartimento di Fisica dell’Università Federico II di Napoli, 80125 , Naples, Italy); Tioukov, V.; Ariga, A.(Albert Einstein Center for Fundamental Physics, Laboratory for High Energy Physics (LHEP), University of Bern, CH-3012, Bern, Switzerland); Naganawa, N.; Toshito, T.; Furusawa, Y.

    2007-01-01

    Beams of Carbon nuclei are used or planned to be used in various centers for cancer treatment around the world because of their therapeutic advantages over proton beams. The knowledge of the fragmentation of Carbon nuclei when they interact with the human body is important to evaluate the spatial profile of their energy deposition in the tissues, hence the damage to the tissues neighboring the tumor. In this respect, the identification of the fragmentation products is a key element. We presen...

  12. Determination of biological transport of oxygen-15 and carbon-11 generated in rats

    International Nuclear Information System (INIS)

    The distribution of induced 15O and 11C activity in live and dead rats was determined following local irradiation with a 32 MeV proton beam. Results indicate that rapid biological redistribution of some of the induced activity occurs within a minute following irradiation. Sufficient activity remains, bound in the intracellular water, to define the proton beam in tissue. Thus, mapping of the induced 15O activity proves to be a valid means of beam localization

  13. Beam commissioning of a superconducting rotating-gantry for carbon-ion radiotherapy

    Science.gov (United States)

    Iwata, Y.; Fujimoto, T.; Matsuba, S.; Fujita, T.; Sato, S.; Furukawa, T.; Hara, Y.; Mizushima, K.; Saraya, Y.; Tansho, R.; Saotome, N.; Shirai, T.; Noda, K.

    2016-10-01

    A superconducting rotating-gantry for carbon-ion radiotherapy was developed. This isocentric gantry can transport carbon ions having kinetic energies of between E=430 and 48 MeV/u to an isocenter over an angle of ±180°, and is further capable of performing three-dimensional raster-scanning irradiation. Construction of the entire rotating-gantry system was completed by the end of September 2015. Prior to beam commissioning, phase-space distributions of extracted carbon beams from the synchrotron were deduced by using an empirical method. In this method, phase-space distributions at the extraction channel of the synchrotron were modeled with 8 parameters, and the best parameters were determined so as to minimize a difference between the calculated and measured beam profiles by using a simplex method. Based on the phase-space distributions, beam optics through the beam-transport lines as well as the rotating gantry were designed. Since horizontal and vertical beam emittances, as extracted slowly from the synchrotron, generally differ with each other, a horizontal-vertical beam coupling would occur when the gantry rotates. Thus, the size and shape of beam spots at the isocenter should vary depending on the gantry angle. To compensate for the difference in the emittances, we employed a method to utilize multiple Coulomb scattering of the beam particles by a thin scatterer. Having compensated for the emittances and designed beam optics through the rotating gantry, beam commissioning over various combinations of gantry angles and beam energies was performed. By finely tuning the superconducting quadrupoles of the rotating gantry, we could successfully obtain the designed beam quality, which satisfies the requirements of scanning irradiation.

  14. Shear strengthening of pre-damaged reinforced concrete beams with carbon fiber reinforced polymer sheet strips

    Institute of Scientific and Technical Information of China (English)

    Feras ALZOUBI; ZHANG Qi; LI Zheng-liang

    2007-01-01

    This paper presents the results of an experimental investigation on the response of pre-damaged reinforced concrete (RC) beam strengthened in shear using applied-epoxy unidirectional carbon fiber reinforced polymer (CFRP) sheet. The reasearch included four test rectangular simply supported RC beams in shear capacity. One is the control beam, two RC beams are damaged to a predetermined degree from ultimate shear capacity of the control beam, and the last beam is left without pre-damaged and then strengthened with using externally bonded carbon fiber reinforced polymer to upgrade their shear capacity. We focused on the damage degree to beams during strengthening, therefore, only the beams with side-bonded CFRPs strips and horizontal anchored strips were used. The results show the feasibility of using CFRPs to restore or increase the load-carrying capacity in the shear of damaged RC beams. The failure mode of all the CFRP-strengthened beams is debonding of CFRP vertical strips. Two prediction available models in ACI-440 and fib European code were compared with the experimental results.

  15. The Precambrian marine carbonate isotope database: version 1.1.

    OpenAIRE

    G. A. Shields; Veizer, J.

    2002-01-01

    We present a compilation of strontium, carbon, and oxygen isotope compositions of roughly 10,000 marine carbonate rocks of Archean - Ordovician age (3800 Ma – 450 Ma). The Precambrian Marine Carbonate Isotope Database (PMCID) has been compiled from 152 published and 3 unpublished articles and books of the past 40 years. Also included are 30 categories of relevant “metadata” that allow detailed comparisons and quality assessments of the isotope data to be made. The PMCID will be updated period...

  16. Bending of metal-filled carbon nanotube under electron beam irradiation

    Directory of Open Access Journals (Sweden)

    Abha Misra

    2012-03-01

    Full Text Available Electron beam irradiation induced, bending of Iron filled, multiwalled carbon nanotubes is reported. Bending of both the carbon nanotube and the Iron contained within the core was achieved using two approaches with the aid of a high resolution electron microscope (HRTEM. In the first approach, bending of the nanotube structure results in response to the irradiation of a pristine kink defect site, while in the second approach, disordered sites induce bending by focusing the electron beam on the graphite walls. The HRTEM based in situ observations demonstrate the potential for using electron beam irradiation to investigate and manipulate the physical properties of confined nanoscale structures.

  17. Numerical Investigation Of The Bombardment Of A Graphene Sheet By A Beam Of Carbon Atoms

    Directory of Open Access Journals (Sweden)

    O.V. Khomenko

    2009-01-01

    Full Text Available Classical molecular dynamics simulations of the bombardment of a graphene sheet by a beam of carbon atoms are carried out. Covalent bonds in the irradiated sample are described by the Brenner potential. The approximation of elastic balls interacting with graphene via the Lennard-Jones potential is used for particles in a beam. The influence of the energy and density of irradiating carbon atoms and of the presence of a thermostat on physical processes occurring during the collisions with the sample is investigated. Energy values of the particles in a beam, which are enough for the sample destruction, are defined.

  18. Enhancement of Charpy impact value by electron beam irradiation of carbon fiber reinforced polymer

    International Nuclear Information System (INIS)

    Influences of electron beam irradiation on Charpy impact value of carbon fiber reinforced polymer (CFRP) have been investigated. The irradiation, which is one of short-time treatments, enhanced the Charpy impact value of CFRP. Furthermore, strengthening of carbon fiber, ductility enhancement of polymer and interface effects on impact test explains the impact value enhancement of CFRP. (author)

  19. Using Pyrolysis Molecular Beam Mass Spectrometry to Characterize Soil Organic Carbon in Native Prairie Soils

    Science.gov (United States)

    The objective of this study was to characterize soil organic carbon (SOC) with pyrolysis molecular beam mass spectrometry (py-MBMS) and then to determine correlations between the mass spectra and associated soil characterization data. Both soil carbon chemistry and the organic forms in which SOC is...

  20. Enhanced electromagnetic properties of nickel nanoparticiles dispersed carbon fiber via electron beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yeong Ju; Kim, Hyun Bin; Lee, Seung Jun; Kang, Phil Hyun [Korea Atomic Energy Research Institute, Jeongeup (Korea, Republic of)

    2015-02-15

    Carbon fiber has received much attention owing to its properties, including a large surface-to-volume ratio, chemical and thermal stability, high thermal and electrical conductivity, and high mechanical strengths. In particular, magnetic nanopowder dispersed carbon fiber has been attractive in technological applications such as the electrochemical capacitor and electromagnetic wave shielding. In this study, the nickel-oxide-nanoparticle dispersed polyacrylonitrile (PAN) fibers were prepared through an electrospinning method. Electron beam irradiation was carried out with a 2.5 MeV beam energy to stabilize the materials. The samples were then heat treated for stabilization and carbonization. The nanofiber surface was analyzed using a field emission scanning electron microscope (FE-SEM). The crystal structures of the carbon matrix and nickel nanopowders were analysed using X-ray diffraction (XRD). In addition, the magnetic and electrical properties were analyzed using a vibrating sample magnetometer (VSM) and 4 point probe. As the irradiation dose increases, the density of the carbon fiber was increased. In addition, the electrical properties of the carbon fiber improved through electron beam irradiation. This is because the amorphous region of the carbon fiber decreases. This electron beam effect of PAN fibers containing nickel nanoparticles confirmed their potential as a high performance carbon material for various applications.

  1. Modeling the Biophysical Effects in a Carbon Beam Delivery Line using Monte Carlo Simulation

    CERN Document Server

    Cho, Ilsung; Cho, Sungho; Kim, Eun Ho; Song, Yongkeun; Shin, Jae-ik; Jung, Won-Gyun

    2016-01-01

    Relative biological effectiveness (RBE) plays an important role in designing a uniform dose response for ion beam therapy. In this study the biological effectiveness of a carbon ion beam delivery system was investigated using Monte Carlo simulation. A carbon ion beam delivery line was designed for the Korea Heavy Ion Medical Accelerator (KHIMA) project. The GEANT4 simulation tool kit was used to simulate carbon beam transporting into media. An incident energy carbon ion beam in the range between 220 MeV/u and 290 MeV/u was chosen to generate secondary particles. The microdosimetric-kinetic (MK) model is applied to describe the RBE of 10% survival in human salivary gland (HSG) cells. The RBE weighted dose was estimated as a function of the penetrating depth of the water phantom along the incident beam direction. A biologically photon-equivalent Spread Out Bragg Peak (SOBP) was designed using the RBE weighted absorbed dose. Finally, the RBE of mixed beams was predicted as a function of the water phantom depth.

  2. Modeling the biophysical effects in a carbon beam delivery line by using Monte Carlo simulations

    Science.gov (United States)

    Cho, Ilsung; Yoo, SeungHoon; Cho, Sungho; Kim, Eun Ho; Song, Yongkeun; Shin, Jae-ik; Jung, Won-Gyun

    2016-09-01

    The Relative biological effectiveness (RBE) plays an important role in designing a uniform dose response for ion-beam therapy. In this study, the biological effectiveness of a carbon-ion beam delivery system was investigated using Monte Carlo simulations. A carbon-ion beam delivery line was designed for the Korea Heavy Ion Medical Accelerator (KHIMA) project. The GEANT4 simulation tool kit was used to simulate carbon-ion beam transport into media. An incident energy carbon-ion beam with energy in the range between 220 MeV/u and 290 MeV/u was chosen to generate secondary particles. The microdosimetric-kinetic (MK) model was applied to describe the RBE of 10% survival in human salivary-gland (HSG) cells. The RBE weighted dose was estimated as a function of the penetration depth in the water phantom along the incident beam's direction. A biologically photon-equivalent Spread Out Bragg Peak (SOBP) was designed using the RBE-weighted absorbed dose. Finally, the RBE of mixed beams was predicted as a function of the depth in the water phantom.

  3. Treatment of industrial effluents using electron beam accelerator and adsorption with activated carbon: a comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira Sampa, M.H. de E-mail: mhosampa@ipen.br; Rela, Paulo Roberto; Las Casas, Alexandre; Nunes Mori, Manoel; Lopes Duarte, Celina

    2004-10-01

    This paper presents preliminary results of a study that compares the use of electron beam processing and activated carbon adsorption to clean up a standardized organic aqueous solution and a real industrial effluent. The electron beam treatment was performed in a batch system using the IPEN's Electron Beam Accelerators from Radiation Dynamics Inc., Dynamitron 37.5 kW. The granular activated carbon removal treatment was performed using charcoal made from wood 'pinus'. If the adequate irradiation dose is delivered to the organic pollutant, it is possible to conclude for the studied compounds that the Electron Beam Process is similar to the activated carbon process in organic removal efficiency.

  4. Practical biological spread-out Bragg peak design of carbon beam

    CERN Document Server

    Kim, Chang Hyeuk; Chang, Seduk; Jang, Hong Suk; Kim, Jeong Hwan; Park, Dong Wook; Hwang, Won Taek; Yang, Tea-Keun

    2015-01-01

    The carbon beams show more advantages on the biological properties compared with proton beams in radiation therapy. The carbon beam shows high linear energy transfer (LET) to medium and it increases the relative biological effectiveness (RBE). To design spread-out Bragg peak (SOBP) of biological dose using carbon beam, a practical method was purposed by using the linear-quadratic (LQ) model and Geant4 based Monte Carlo simulation code. The various Bragg peak profiles and LET was calculated for each slice at the target region. To generate appropriate biological SOBP, a set of weighting factor, which is a power function in terms of energy step, was applied to the obtained each physical dose. The designed biological SOBP showed 1.34 % of uniformity.

  5. Three dimensional reconstruction of therapeutic carbon ion beams in phantoms using single secondary ion tracks

    CERN Document Server

    Reinhart, Anna Merle; Jakubek, Jan; Martisikova, Maria

    2016-01-01

    Carbon ion beam radiotherapy enables a very localised dose deposition. However, already small changes in the patient geometry or positioning errors can significantly distort the dose distribution. A live monitoring system of the beam delivery within the patient is therefore highly desirable and could improve patient treatment. We present a novel three-dimensional imaging method of the beam in the irradiated object, exploiting the measured tracks of single secondary ions emerging under irradiation. The secondary particle tracks are detected with a TimePix stack, a set of parallel pixelated semiconductor detectors. We developed a three-dimensional reconstruction algorithm based on maximum likelihood expectation maximisation. We demonstrate the applicability of the new method in an irradiation of a cylindrical PMMA phantom of human head size with a carbon ion pencil beam of 226MeV/u. The beam image in the phantom is reconstructed from a set of 9 discrete detector positions between -80 and 50 degrees from the bea...

  6. Effect of electron beam irradiation on the properties of carbon fiber

    International Nuclear Information System (INIS)

    Carbon fibers are used as a reinforcement material in an epoxy matrix in advanced composites due to their high mechanical strength, rigidity and low specific density. An important aspect of the mechanical properties of composites is associated to the adhesion between the surface of the carbon fiber and the epoxy matrix. This paper aimed to evaluate the effects of electron beam irradiation on the physicochemical properties of carbon fibers to obtain better adhesion properties in resultant composite. Chemical structure and surface of carbon fiber were determined by FT-IR, elemental analysis and X-ray photoelectron spectroscopy, which indicated that the oxygen content increased significantly with increasing the radiation dose. Thermal stability of the carbon fibers was studied via the thermal gravimetric analysis. Surface morphology of carbon fiber was analyzed by scanning electron microscope. It was found that the degree of surface roughness was increased by electron beam irradiation

  7. Stress corrosion cracking tests on electron beam welded carbon steel specimens in carbonate-bicarbonate solution

    International Nuclear Information System (INIS)

    Stress corrosion cracking tests have been performed on tapered carbon steel test pieces containing electron beam welds with a view to defining susceptibility to such cracking in a carbonate-bicarbonate solution at 90 C and an appropriate electrode potential. The tests involved applying cyclic loads to the specimens and it is shown that the threshold stress for cracking reduces linearly with increase in the magnitude of the cyclic load component. Extrapolation of these trends to zero fluctuating stress indicates static load threshold stresses in the vicinity of the yield stress (i.e. about 300 N/mm2 for parent plate without a weld, 400 N/mm2 for specimens with welds on one side only and 600 N/mm2 for specimens having welds penetrating through the thickness of the specimen). The averages of the maximum crack velocities observed were least for parent plate material and greatest for weld metal, the former being essentially intergranular in morphology and the latter mostly transgranular, with heat affected zone material being intermediate between these extremes. (author)

  8. Water equivalent thickness values of materials used in beams of protons, helium, carbon and iron ions.

    Science.gov (United States)

    Zhang, Rui; Taddei, Phillip J; Fitzek, Markus M; Newhauser, Wayne D

    2010-05-01

    Heavy charged particle beam radiotherapy for cancer is of increasing interest because it delivers a highly conformal radiation dose to the target volume. Accurate knowledge of the range of a heavy charged particle beam after it penetrates a patient's body or other materials in the beam line is very important and is usually stated in terms of the water equivalent thickness (WET). However, methods of calculating WET for heavy charged particle beams are lacking. Our objective was to test several simple analytical formulas previously developed for proton beams for their ability to calculate WET values for materials exposed to beams of protons, helium, carbon and iron ions. Experimentally measured heavy charged particle beam ranges and WET values from an iterative numerical method were compared with the WET values calculated by the analytical formulas. In most cases, the deviations were within 1 mm. We conclude that the analytical formulas originally developed for proton beams can also be used to calculate WET values for helium, carbon and iron ion beams with good accuracy.

  9. Water equivalent thickness values of materials used in beams of protons, helium, carbon and iron ions.

    Science.gov (United States)

    Zhang, Rui; Taddei, Phillip J; Fitzek, Markus M; Newhauser, Wayne D

    2010-05-01

    Heavy charged particle beam radiotherapy for cancer is of increasing interest because it delivers a highly conformal radiation dose to the target volume. Accurate knowledge of the range of a heavy charged particle beam after it penetrates a patient's body or other materials in the beam line is very important and is usually stated in terms of the water equivalent thickness (WET). However, methods of calculating WET for heavy charged particle beams are lacking. Our objective was to test several simple analytical formulas previously developed for proton beams for their ability to calculate WET values for materials exposed to beams of protons, helium, carbon and iron ions. Experimentally measured heavy charged particle beam ranges and WET values from an iterative numerical method were compared with the WET values calculated by the analytical formulas. In most cases, the deviations were within 1 mm. We conclude that the analytical formulas originally developed for proton beams can also be used to calculate WET values for helium, carbon and iron ion beams with good accuracy. PMID:20371908

  10. Effective source size, radial, angular and energy spread of therapeutic 11C positron emitter beams produced by 12C fragmentation

    International Nuclear Information System (INIS)

    The use of positron emitter light ion beams in combination with PET (Positron Emission Tomography) and PET–CT (Computed Tomography) imaging could significantly improve treatment verification and dose delivery imaging during radiation therapy. The present study is dedicated to the analysis of the beam quality in terms of the effective source size, as well as radial, angular and energy spread of the 11C ion beam produced by projectile fragmentation of a primary point monodirectional and monoenergetic 12C ion beam in a dedicated range shifter of different materials. This study was performed combining analytical methods describing the transport of particles in matter and the Monte Carlo code SHIELD-HIT+. A high brilliance and production yield of 11C fragments with a small effective source size and emittance is best achieved with a decelerator made of two media: a first liquid hydrogen section of about 20 cm followed by a hydrogen rich section of variable length. The calculated intensity of the produced 11C ion beam ranges from about 5% to 8% of the primary 12C beam intensity depending on the exit energy and the acceptance of the beam transport system. The angular spread is lower than 1 degree for all the materials studied, but the brilliance of the beam is the highest with the proposed mixed decelerator

  11. Measurement of the transverse four-dimensional beam rms-emittance of an intense uranium beam at 11.4 MeV/u

    Science.gov (United States)

    Xiao, C.; Groening, L.; Gerhard, P.; Maier, M.; Mickat, S.; Vormann, H.

    2016-06-01

    Knowledge of the transverse four-dimensional beam rms-parameters is essential for applications that involve lattice elements that couple the two transverse degrees of freedom (planes). Usually pepper-pots are used for measuring these beam parameters. However, for ions their application is limited to energies below 150 keV/u. This contribution is on measurements of the full transverse four-dimensional second-moments beam matrix of high intensity uranium ions at an energy of 11.4 MeV/u. The combination of skew quadrupoles with a slit/grid emittance measurement device has been successfully applied.

  12. Nano-carbon black and carbon fiber as conductive materials for the diagnosing of the damage of concrete beam

    OpenAIRE

    Yining Ding; Zhipei Chen; Zhibo Han; Yulin Zhang; Torgal, Fernando Pacheco

    2013-01-01

    The nano-carbon black (NCB) and carbon fiber (CF) as electric conductive materials were added into the concrete. The effect of the NCB and CF on the mechanical properties and on the fractional change in resistance (FCR) of concrete was investigated. The relationships among the FCR, the strain of initial geometrical neutral axis (IGNA) and the beam damage degree were developed. The results showed that the relationship between the FCR and IGNA strain can be described by the First Or...

  13. Carbon-11-labeled daunorubicin and verapamil for probing P-glycoprotein in tumors with PET

    NARCIS (Netherlands)

    Elsinga, PH; Franssen, EJF; Hendrikse, NH; Fluks, L; Weemaes, AMA; vanderGraaf, WTA; deVries, GE; Visser, GM; Vaalburg, W

    1996-01-01

    One of the mechanisms for multidrug resistance (MDR) of tumors is an overexpression of the P-glycoprotein (P-gp). The cytostatic agent daunorubicin and the modulator verapamil were labeled with C-11 to probe P-gp with PET. Methods: Carbon-11-daunorubicin was prepared from (CCH2N2)-C-11 with an aldeh

  14. Geant4 Simulation Study of Dose Distribution and Energy Straggling for Proton and Carbon Ion Beams in Water

    OpenAIRE

    Zhao Qiang; Zhang Zheng; Li Yang

    2016-01-01

    Dose distribution and energy straggling for proton and carbon ion beams in water are investigated by using a hadrontherapy model based on the Geant4 toolkit. By gridding water phantom in N×N×N voxels along X, Y and Z axes, irradiation dose distribution in all the voxels is calculated. Results indicate that carbon ion beams have more advantages than proton beams. Proton beams have bigger width of the Bragg peak and broader lateral dose distribution than carbon ion beams for the same position o...

  15. SU-F-BRE-11: Neutron Measurements Around the Varian TrueBeam Linac

    Energy Technology Data Exchange (ETDEWEB)

    Maglieri, R; Seuntjens, J; Kildea, J [McGill University, Montreal, QC (Canada); Liang, L; DeBlois, F [Jewish General Hospital, Montreal, QC (Canada); Evans, M [Montreal General Hospital, Montreal, QC (Canada); Licea, A [Canadian Nuclear Safety Comission, Ottawa, Ontario (Canada); Dubeau, J; Witharana, S [Detec, Gatineau, QC (Canada)

    2014-06-15

    Purpose: With the emergence of flattening filter free (FFF) photon beams, several authors have noted many advantages to their use. One such advantage is the decrease in neutron production by photonuclear reactions in the linac head. In the present work we investigate the reduction in neutrons from a Varian TrueBeam linac using the Nested Neutron Spectrometer (NNS, Detec). The neutron spectrum, total fluence and source strength were measured and compared for 10 MV with and without flattening filter and the effect of moderation by the room and maze was studied for the 15 MV beam. Methods: The NNS, similar to traditional Bonner sphere detectors but operated in current mode, was used to measure the neutron fluence and spectrum. The NNS was validated for use in high dose rate environments using Monte Carlo simulations and calibrated at NIST and NRC Canada. Measurements were performed at several positions within the treatment room and maze with the linac jaws closed to maximize neutron production. Results: The measurements showed a total fluence reduction between 35-40% in the room and maze when the flattening filter was removed. The neutron source strength Qn was calculated from in-room fluence measurements and was found to be 0.042 × 10{sup 2} n/Gy, 0.026 × 10{sup 2} n/Gy and 0.59 × 101{sup 2} n/Gy for the 10 MV, the 10 MV FFF and 15 MV beams, respectively. We measured ambient equivalent doses of 11 mSv/hr, 7 mSv/hr and 218 mSv/hr for the 10 MV, 10 MV FFF and 15 MV by the head. Conclusion: Our measurements revealed a decrease in total fluence, neutron source strength and equivalent dose of approximately 35-40% across the treatment room for the FFF compared to FF modes. This demonstrates, as expected, that the flattening filter is a major component of the neutron production for the TrueBeam. The authors greatly acknowledge support form the Canadian Nuclear Commission and the Natural Sciences and Engineering Research Council of Canada through the CREATE program. Co

  16. SU-F-BRE-11: Neutron Measurements Around the Varian TrueBeam Linac

    International Nuclear Information System (INIS)

    Purpose: With the emergence of flattening filter free (FFF) photon beams, several authors have noted many advantages to their use. One such advantage is the decrease in neutron production by photonuclear reactions in the linac head. In the present work we investigate the reduction in neutrons from a Varian TrueBeam linac using the Nested Neutron Spectrometer (NNS, Detec). The neutron spectrum, total fluence and source strength were measured and compared for 10 MV with and without flattening filter and the effect of moderation by the room and maze was studied for the 15 MV beam. Methods: The NNS, similar to traditional Bonner sphere detectors but operated in current mode, was used to measure the neutron fluence and spectrum. The NNS was validated for use in high dose rate environments using Monte Carlo simulations and calibrated at NIST and NRC Canada. Measurements were performed at several positions within the treatment room and maze with the linac jaws closed to maximize neutron production. Results: The measurements showed a total fluence reduction between 35-40% in the room and maze when the flattening filter was removed. The neutron source strength Qn was calculated from in-room fluence measurements and was found to be 0.042 × 102 n/Gy, 0.026 × 102 n/Gy and 0.59 × 1012 n/Gy for the 10 MV, the 10 MV FFF and 15 MV beams, respectively. We measured ambient equivalent doses of 11 mSv/hr, 7 mSv/hr and 218 mSv/hr for the 10 MV, 10 MV FFF and 15 MV by the head. Conclusion: Our measurements revealed a decrease in total fluence, neutron source strength and equivalent dose of approximately 35-40% across the treatment room for the FFF compared to FF modes. This demonstrates, as expected, that the flattening filter is a major component of the neutron production for the TrueBeam. The authors greatly acknowledge support form the Canadian Nuclear Commission and the Natural Sciences and Engineering Research Council of Canada through the CREATE program. Co-authors Dubeau and

  17. Total cyanide mass measurement with micro-ion selective electrode for determination of specific activity of carbon-11 cyanide

    International Nuclear Information System (INIS)

    In this research, we aim to directly measure the specific activity (SA) of the carbon-11 cyanide ([11C]CN¯) produced by our in-house built automated [11C]HCN production system and to identify the major sources of 12C-cyanide (12CN¯). The [11C]CN¯ is produced from [11C]CO2, which is generated by the 14N(p,α)11C nuclear reaction using a cyclotron. Direct measurement of cyanide concentrations was accomplished using a relatively inexpensive, and easy to use ion selective electrode (ISE) which offered an appropriate range of sensitivity for detecting mass. Multiple components of the [11C]HCN production system were isolated in order to determine their relative contributions to 12CN¯ mass. It was determined that the system gases were responsible for approximately 30% of the mass, and that the molecular sieve/nickel furnace unit contributed approximately 70% of the mass. Beam on target (33 µA for 1 and 10 min) did not contribute significantly to the mass. Additionally, we compared the SA of our [11C]HCN precursor determined using the ISE to the SA of our current [11C]CN¯ derived radiotracers determined by HPLC to assure there was no significant difference between the two methods. These results are the first reported use of an ion selective electrode to determine the SA of no-carrier-added cyanide ion, and clearly show that it is a valuable, inexpensive and readily available tool suitable for this purpose. - Highlights: • Measurement of cyanide mass contribution from different component of automated [11C]HCN production system. • Determination of specific activity of [11C]HCN by micro ion selective electrode

  18. Evaluation of the range shifter model for proton pencil-beam scanning for the Eclipse v.11 treatment planning system.

    Science.gov (United States)

    Matysiak, Witold; Yeung, Daniel; Slopsema, Roelf; Li, Zuofeng

    2016-01-01

    Existing proton therapy pencil-beam scanning (PBS) systems have limitations on the minimum range to which a patient can be treated. This limitation arises from practical considerations, such as beam current intensity, layer spacing, and delivery time. The range shifter (RS) - a slab of stopping material inserted between the nozzle and the patient - is used to reduce the residual range of the incident beam so that the treatment ranges can be extended to shallow depths. Accurate modeling of the RS allows one to calculate the beam spot size entering the patient, given the proton energy, for arbitrary positions and thicknesses of the RS in the beam path. The Eclipse version 11 (v11) treatment planning system (TPS) models RS-induced beam widening by incorporating the scattering properties of the RS material into the V-parameter. Monte Carlo simulations with Geant4 code and analytical calculations using the Fermi-Eyges (FE) theory with Highland approximation of multiple Coulomb scattering (MCS) were employed to calculate proton beam widening due to scattering in the RS. We demonstrated that both methods achieved consistent results and could be used as a benchmark for evaluating the Eclipse V-parameter model. In most cases, the V-parameter model correctly predicted the beam spot size after traversing the RS. However, Eclipse did not enforce the constraint for a nonnegative covariance matrix when fitting the spot sizes to derive the phase space parameters, which resulted in incorrect calculations under specific conditions. In addition, Eclipse v11 incorrectly imposed limits on the individual values of the phase space parameters, which could lead to incorrect spot size values in the air calculated for beams with spot sigmas <3.8 mm. Notably, the TPS supplier (Varian) and hardware vendor (Ion Beam Applications) inconsistently refer to the RS position, which may result in improper spot size calculations. PMID:27074461

  19. Hadron Cancer Therapy - relative merits of X-ray, proton and carbon beams

    Science.gov (United States)

    Jakel, Oliver

    2014-03-01

    -Heidelberg University has a long experience in radiotherapy with carbon ions, starting with a pilot project at GSI in 1997. This project was jointly run by the Dep. for Radiation Oncology of Heidelberg University, GSI and the German Cancer Research Center (DKFZ). A hospital based heavy ion center at Heidelberg University, the Heidelberg Ion Beam Therapy Center (HIT) was proposed by the same group in 1998 and started clinical operation in late 2009. Since then nearly 2000 patients were treated with beams of carbon ions and protons. Just recently the operation of the world's first and only gantry for heavy ions also started at HIT. Patient treatments are performed in three rooms. Besides that, a lot of research projects are run in the field of Medical Physics and Radiobiology using a dedicated experimental area and the possibility to use beams of protons, carbon, helium and oxygen ions being delivered with the raster scanning technique.

  20. Nanoscale Soldering of Positioned Carbon Nanotubes using Highly Conductive Electron Beam Induced Gold Deposition

    DEFF Research Database (Denmark)

    Madsen, Dorte Nørgaard; Mølhave, Kristian; Mateiu, Ramona Valentina;

    2003-01-01

    We have developed an in-situ method for controlled positioning of carbon nanotubes followed by highly conductive contacting of the nanotubes, using electron beam assisted deposition of gold. The positioning and soldering process takes place inside an Environmental Scanning Electron Microscope (E...... in a carbon matrix. Nanoscale soldering of multi-walled carbon nanotubes (MWNT) onto microelectrodes was achieved by deposition of a conducting gold line across a contact point between nanotube and electrode. The solderings were found to be mechanically stronger than the carbon nanotubes. We have positioned...

  1. Geant4 Simulation Study of Dose Distribution and Energy Straggling for Proton and Carbon Ion Beams in Water

    Directory of Open Access Journals (Sweden)

    Zhao Qiang

    2016-01-01

    Full Text Available Dose distribution and energy straggling for proton and carbon ion beams in water are investigated by using a hadrontherapy model based on the Geant4 toolkit. By gridding water phantom in N×N×N voxels along X, Y and Z axes, irradiation dose distribution in all the voxels is calculated. Results indicate that carbon ion beams have more advantages than proton beams. Proton beams have bigger width of the Bragg peak and broader lateral dose distribution than carbon ion beams for the same position of Bragg peaks. Carbon ion has a higher local ionization density and produces more secondary electrons than proton, so carbon ion beams can achieve a higher value of relative biological effectiveness.

  2. Cancer stem cells: The potential of carbon ion beam radiation and new radiosensitizers (Review).

    Science.gov (United States)

    Baek, Sung-Jae; Ishii, Hideshi; Tamari, Keisuke; Hayashi, Kazuhiko; Nishida, Naohiro; Konno, Masamitsu; Kawamoto, Koichi; Koseki, Jun; Fukusumi, Takahito; Hasegawa, Shinichiro; Ogawa, Hisataka; Hamabe, Atsushi; Miyo, Masaaki; Noguchi, Kozo; Seo, Yuji; Doki, Yuichiro; Mori, Masaki; Ogawa, Kazuhiko

    2015-11-01

    Cancer stem cells (CSCs) are a small population of cells in cancer with stem-like properties such as cell proliferation, multiple differentiation and tumor initiation capacities. CSCs are therapy-resistant and cause cancer metastasis and recurrence. One key issue in cancer therapy is how to target and eliminate CSCs, in order to cure cancer completely without relapse and metastasis. To target CSCs, many cell surface markers, DNAs and microRNAs are considered as CSC markers. To date, the majority of the reported markers are not very specific to CSCs and are also present in non-CSCs. However, the combination of several markers is quite valuable for identifying and targeting CSCs, although more specific identification methods are needed. While CSCs are considered as critical therapeutic targets, useful treatment methods remain to be established. Epigenetic gene regulators, microRNAs, are associated with tumor initiation and progression. MicroRNAs have been recently considered as promising therapeutic targets, which can alter the therapeutic resistance of CSCs through epigenetic modification. Moreover, carbon ion beam radiotherapy is a promising treatment for CSCs. Evidence indicates that the carbon ion beam is more effective against CSCs than the conventional X-ray beam. Combination therapies of radiosensitizing microRNAs and carbon ion beam radiotherapy may be a promising cancer strategy. This review focuses on the identification and treatment resistance of CSCs and the potential of microRNAs as new radiosensitizers and carbon ion beam radiotherapy as a promising therapeutic strategy against CSCs. PMID:26330103

  3. Strong Metal-Support Interaction: Growth of Individual Carbon Nanofibers from Amorphous Carbon Interacting with an Electron Beam

    DEFF Research Database (Denmark)

    Zhang, Wei; Kuhn, Luise Theil

    2013-01-01

    The article discusses the growth behavior of carbon nanofibers (CNFs). It mentions that CNFs can be synthesized using methods such as arc-discharge, laser ablation and chemical vapor deposition. It further states that CNFs can be grown from a physical mixing of amorphous carbon and CGO/Ni nanopar......The article discusses the growth behavior of carbon nanofibers (CNFs). It mentions that CNFs can be synthesized using methods such as arc-discharge, laser ablation and chemical vapor deposition. It further states that CNFs can be grown from a physical mixing of amorphous carbon and CGO....../Ni nanoparticles, devoid of any gaseous carbon source and external heating and stimulated by an electron beam in a 300 kilo volt transmission electron microscope....

  4. Average Frequency – RA Value for Reinforced Concrete Beam Strengthened with Carbon Fibre Sheet

    Directory of Open Access Journals (Sweden)

    Mohamad M. Z.

    2016-01-01

    Full Text Available Acoustic Emission (AE is one of the tools that can be used to detect the crack and to classify the type of the crack of reinforced concrete (RC structure. Dislocation or movement of the material inside the RC may release the transient elastic wave. In this situation, AE plays important role whereby it can be used to capture the transient elastic wave and convert it into AE parameters such as amplitude, count, rise time and duration. Certain parameter can be used directly to evaluate the crack behavior. But in certain cases, the AE parameter needs to add and calculate by using related formula in order to observe the behavior of the crack. Using analysis of average frequency and RA value, the crack can be classified into tensile or shear cracks. In this study, seven phases of increasing static load were used to observe the crack behavior. The beams were tested in two conditions. For the first condition, the beams were tested in original stated without strengthened with carbon fibre sheet (CFS at the bottom of the beam or called as tension part of the beam. For the second condition, the beams were strengthened with CFS at the tension part of the beam. It was found that, beam wrapped with CFS enhanced the strength of the beams in term of maximum ultimate load. Based on the relationship between average frequency (AF and RA value, the cracks of the beams can be classified.

  5. Groningen experience in production and application of fluorine-18 and carbon-11 labeled radiopharmaceuticals

    International Nuclear Information System (INIS)

    In this presentation the preparation of these tracers (fluorine-18 and carbon-11 labeled radiopharmaceuticals), as well as the present stage of development and evaluation, and the potential application in oncology will be discussed. (author)

  6. Advanced Electron Beam Ion Sources (EBIS) for 2-nd generation carbon radiotherapy facilities

    International Nuclear Information System (INIS)

    In this work we analyze how advanced Electron Beam Ion Sources (EBIS) can facilitate the progress of carbon therapy facilities. We will demonstrate that advanced ion sources enable operation of 2-nd generation ion beam therapy (IBT) accelerators. These new accelerator concepts with designs dedicated to IBT provide beams better suited for therapy and, are more cost efficient than contemporary IBT facilities. We will give a sort overview of the existing new IBT concepts and focus on those where ion source technology is the limiting factor. We will analyse whether this limitation can be overcome in the near future thanks to ongoing EBIS development

  7. Analysis of the strength and stiffness of timber beams reinforced with carbon fiber and glass fiber

    Directory of Open Access Journals (Sweden)

    Juliano Fiorelli

    2003-06-01

    Full Text Available An experimental analysis of pinewood beams (Pinus caribea var hondurensis reinforced with glass and/or carbon fibers is discussed. The theoretical model employed to calculate the beam's bending strength takes into account the timber's ultimate limit states of tensile strength and failure by compression, considering a model of fragile elastic tension and plastic elastic compression. The validity of the theoretical model is confirmed by a comparison of the theoretical and experimental results, while the efficiency of the fiber reinforcement is corroborated by the increased strength and stiffness of the reinforced timber beams.

  8. In vivo kinetics and displacement study of a carbon-11-labeled hallucinogen, N,N-[11C]dimethyltryptamine

    International Nuclear Information System (INIS)

    The endogenous hallucinogen, N,N-dimethyltryptamine (DMT), was labeled with carbon-11 and its regional distribution in rat brain studied. [11C]DMT showed higher accumulation in the cerebral cortex, caudate putamen, and amygdaloid nuclei. Studies of the subcellular distribution of [11C]DMT revealed the specific localization in the fractions enriched with serotonin receptors only when a very low dose was injected into rats. The proportions of the radioactivity in receptor-rich fractions were greatly enhanced by pretreatment with the monoamine oxidase inhibitor, pargyline. Specific binding of [11C]DMT to serotonin receptors in dog brain was demonstrated by a positron emission tomographic study in which 5-methoxy-N,N-dimethyltryptamine caused approximately 20% displacement of the radioligand from the receptors. (orig.)

  9. In vivo kinetics and displacement study of a carbon-11-labeled hallucinogen, N,N-(/sup 11/C)dimethyltryptamine

    Energy Technology Data Exchange (ETDEWEB)

    Yanai, Kazuhiko; Ido, Tatsuo; Ishiwata, Kiichi; Takahashi, Toshihiro; Iwata, Ren; Hatazawa, Jun; Matsuzawa, Taiju

    1986-07-01

    The endogenous hallucinogen, N,N-dimethyltryptamine (DMT), was labeled with carbon-11 and its regional distribution in rat brain studied. (/sup 11/C)DMT showed higher accumulation in the cerebral cortex, caudate putamen, and amygdaloid nuclei. Studies of the subcellular distribution of (/sup 11/C)DMT revealed the specific localization in the fractions enriched with serotonin receptors only when a very low dose was injected into rats. The proportions of the radioactivity in receptor-rich fractions were greatly enhanced by pretreatment with the monoamine oxidase inhibitor, pargyline. Specific binding of (/sup 11/C)DMT to serotonin receptors in dog brain was demonstrated by a positron emission tomographic study in which 5-methoxy-N,N-dimethyltryptamine caused approximately 20% displacement of the radioligand from the receptors.

  10. In vivo kinetics and displacement study of a carbon-11-labeled hallucinogen, N,N-[11C]dimethyltryptamine.

    Science.gov (United States)

    Yanai, K; Ido, T; Ishiwata, K; Hatazawa, J; Takahashi, T; Iwata, R; Matsuzawa, T

    1986-01-01

    The endogenous hallucinogen, N,N-dimethyltryptamine (DMT), was labeled with carbon-11 and its regional distribution in rat brain studied. [11C]DMT showed higher accumulation in the cerebral cortex, caudate putamen, and amygdaloid nuclei. Studies of the subcellular distribution of [11C]DMT revealed the specific localization in the fractions enriched with serotonin receptors only when a very low dose was injected into rats. The proportions of the radioactivity in receptor-rich fractions were greatly enhanced by pretreatment with the monoamine oxidase inhibitor, pargyline. Specific binding of [11C]DMT to serotonin receptors in dog brain was demonstrated by a positron emission tomographic study in which 5-methoxy-N,N-dimethyltryptamine caused approximately 20% displacement of the radioligand from the receptors. PMID:3489620

  11. Design and analysis of automotive carbon fiber composite bumper beam based on finite element analysis

    Directory of Open Access Journals (Sweden)

    Tie Wang

    2015-06-01

    Full Text Available In this article, the most important part of the automotive front bumper system, namely, the bumper beam, is studied by changing the material and thickness to improve the crashworthiness performance in low-velocity impact. According to the low-speed standard of automotives stated in E.C.E. United Nations Agreement, Regulation no. 42, the low-velocity impact simulation based on finite element analysis is carried out. Lightweight is the main purpose of this article. First, the bumper beam analysis is accomplished for carbon fiber composite and steel material to analyze their deformation, weight, impact force, energy absorption, and the acceleration of the impactor. As a consequence, the bumper beam made by carbon fiber composite achieves better impact behavior. Second, on the purpose of lightweight, the bumper beams of different thickness including 5.4, 6, 6.6, and 7.2 mm are investigated. The results show that the 5.4 mm bumper beam is the best selection without sacrificing the impact performance. Third, according to the stress distribution, the thickness distribution of the bumper beam is changed to get better lightweight results. It is indicated that the weight of the improved bumper beam is further reduced and the impact performance is not weakened.

  12. Carbon-11 labelled analogs of alanine by the Strecker synthesis

    Energy Technology Data Exchange (ETDEWEB)

    Prenant, C.; Theobald, A.; Siegel, T.; Joachim, J.; Weber, K.; Haberkorn, U.; Oberdorfer, F. [Deutsches Krebsforschungszentrum, Heidelberg (Germany)

    1995-06-01

    Derivatives of alanine, {alpha}-[2-sup(11)C]aminoisobutyric acid 1a and {alpha}-(N-methyl)-[2-{sup 11} C]aminoisobutyric acid 1b were prepared for the in-vivo study of amino acid transport phenomena by positron-emission-tomography (PET). Compounds 1a and 1b were obtained by a Zelinski-Stadnikoff variant of the Strecker {alpha}-amino acid synthesis from in-situ formed [{sup 11} C]acetone in presence of sodium cyanide and either ammonium sulfate (for 1a) or methylamine hydrochloride (for 1b). The complete preparation required 50 min from the end of [{sup 11}C]CO{sub 2} production, and delivered 1.2 - 2 GBq of labelled product for application (2.4 -4%); not corrected for decay; related to trapped [{sup C}]CO{sub 2}. The specific activity of the labelled products was 16 to 20 GBq{center_dot}{mu}mol{sup -1}. The radiochemical and chemical purity of the preparations was greater than 98%. (Author).

  13. Beam asymmetry Σ in π0 photoproduction off protons bound in carbon nuclei

    International Nuclear Information System (INIS)

    In order to study the dynamics of the inner components of the nucleon, its excitation spectrum is investigated through meson-photoproduction. Due to the strong overlap of the nucleon's excited states, it is insufficient to determine the cross section only. To identify all resonance contributions unambiguously, single and double polarization observables have to be measured. At the Crystal Barrel experiment at ELSA in Bonn, this is achieved utilizing linearly or circularly polarized photons and longitudinally or transversely polarized nucleons. Polarized protons are realized in a butanol target, which consists of hydrogen, oxygen and carbon. A pure carbon target was used to perform a background measurement. The results for the beam asymmetry Σ in π0 photoproduction, obtained with a carbon target and a linearly polarized photon beam, are presented. Furthermore, the influence of carbon background on the measured polarization observables is discussed.

  14. Reinforcement of timber beams with carbon fibers reinforced plastics

    Science.gov (United States)

    Gugutsidze, G.; Draškovič, F.

    2010-06-01

    Wood is a polymeric material with many valuable features and which also lacks some negative features. In order to keep up with high construction rates and the minimization of negative effects, wood has become one of the most valuable materials in modern engineering. But the use of timber material economically is also an actual problem in order to protect the environment and improve natural surroundings. A panel of scientists is interested in solving these problems and in creating rational structures, where timber can be used efficiently. These constructions are as follows: glue-laminated (gluelam), composed and reinforced wooden constructions. Composed and reinforced wooden constructions are examined less, but according to researches already carried out, it is clear that significant work can be accomplished in creating rational, highly effective and economic timber constructions. The paper deals with research on the formation of composed fiber-reinforced beams (CFRP) made of timber and provide evidence of their effectiveness. The aim of the paper is to investigate cross-bending of CFRP-reinforced gluelaminated timber beams. According to the results we were able to determine the additional effectiveness of reinforcement with CFRP (which depends on the CFRP material's quality, quantity and module of elasticity) on the mechanical features of timber and a whole beam.

  15. Experimental control of the beam properties of laser-accelerated protons and carbon ions

    Energy Technology Data Exchange (ETDEWEB)

    Amin, Munib

    2008-12-15

    The laser generation of energetic high quality beams of protons and heavier ions has opened up the door to a plethora of applications. These beams are usually generated by the interaction of a short pulse high power laser with a thin metal foil target. They could already be applied to probe transient phenomena in plasmas and to produce warm dense matter by isochoric heating. Other applications such as the production of radioisotopes and tumour radiotherapy need further research to be put into practice. To meet the requirements of each application, the properties of the laser-accelerated particle beams have to be controlled precisely. In this thesis, experimental means to control the beam properties of laser-accelerated protons and carbon ions are investigated. The production and control of proton and carbon ion beams is studied using advanced ion source designs: Experiments concerning mass-limited (i.e. small and isolated) targets are conducted. These targets have the potential to increase both the number and the energy of laser-accelerated protons. Therefore, the influence of the size of a plane foil target on proton beam properties is measured. Furthermore, carbon ion sources are investigated. Carbon ions are of particular interest in the production of warm dense matter and in cancer radiotherapy. The possibility to focus carbon ion beams is investigated and a simple method for the production of quasi-monoenergetic carbon ion beams is presented. This thesis also provides an insight into the physical processes connected to the production and the control of laser-accelerated ions. For this purpose, laser-accelerated protons are employed to probe plasma phenomena on laser-irradiated targets. Electric fields evolving on the surface of laser-irradiated metal foils and hollow metal foil cylinders are investigated. Since these fields can be used to displace, collimate or focus proton beams, understanding their temporal and spatial evolution is crucial for the design of

  16. 11C标记Tamoxifen的制备%PREPARATION OF CARBON-11 LABELLED TAMOXIFEN

    Institute of Scientific and Technical Information of China (English)

    刘宁; Shi.,O.Y

    2000-01-01

    报道了N-去甲基-Tamoxifen (N-Demethyltamoxifen)和11C标记Tamoxifen (11C-Tamoxifen)的制备及高效液相色谱(HPLC)分离分析方法.先将Tamoxifen柠檬酸盐(Tamoxifen Citrate)转换成无盐Tamoxifen(Tamoxifen free base),然后与1-氯乙基-氯甲酸酯(ACE.Cl)反应生成N-去甲基-Tamoxifen.N-去甲基-Tamoxifen与11CH3I在130℃下反应10min,即生成11C- Tamoxifen.标记物用μBonapak TM C18柱HPLC进行分离纯化后,制成11C-Tamoxifen注射液.从停止核反应开始,整个标记及分离纯化过程需时50~60min,标记率可达60%.

  17. Dosimetric characterization of a microDiamond detector in clinical scanned carbon ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Marinelli, Marco; Prestopino, G., E-mail: giuseppe.prestopino@uniroma2.it; Verona, C.; Verona-Rinati, G. [INFN—Dipartimento di Ingegneria Industriale, Università di Roma “Tor Vergata,” Via del Politecnico 1, Roma 00133 (Italy); Ciocca, M.; Mirandola, A.; Mairani, A. [Fondazione CNAO, Strada Campeggi 53, Pavia 27100 (Italy); Raffaele, L. [INFN—Laboratori Nazionali del Sud, Via S. Sofia 62, Catania 95123, Italy and Fondazione CNAO, Strada Campeggi 53, Pavia 27100 (Italy); Magro, G. [INFN—Dipartimento di Fisica, Università degli Studi di Pavia, Via U. Bassi 6, Pavia 27100, Italy and Fondazione CNAO, Strada Campeggi 53, Pavia 27100 (Italy)

    2015-04-15

    Purpose: To investigate for the first time the dosimetric properties of a new commercial synthetic diamond detector (PTW microDiamond) in high-energy scanned clinical carbon ion beams generated by a synchrotron at the CNAO facility. Methods: The detector response was evaluated in a water phantom with actively scanned carbon ion beams ranging from 115 to 380 MeV/u (30–250 mm Bragg peak depth in water). Homogeneous square fields of 3 × 3 and 6 × 6 cm{sup 2} were used. Short- and medium-term (2 months) detector response stability, dependence on beam energy as well as ion type (carbon ions and protons), linearity with dose, and directional and dose-rate dependence were investigated. The depth dose curve of a 280 MeV/u carbon ion beam, scanned over a 3 × 3 cm{sup 2} area, was measured with the microDiamond detector and compared to that measured using a PTW Advanced Markus ionization chamber, and also simulated using FLUKA Monte Carlo code. The detector response in two spread-out-Bragg-peaks (SOBPs), respectively, centered at 9 and 21 cm depths in water and calculated using the treatment planning system (TPS) used at CNAO, was measured. Results: A negligible drift of detector sensitivity within the experimental session was seen, indicating that no detector preirradiation was needed. Short-term response reproducibility around 1% (1 standard deviation) was found. Only 2% maximum variation of microDiamond sensitivity was observed among all the evaluated proton and carbon ion beam energies. The detector response showed a good linear behavior. Detector sensitivity was found to be dose-rate independent, with a variation below 1.3% in the evaluated dose-rate range. A very good agreement between measured and simulated Bragg curves with both microDiamond and Advanced Markus chamber was found, showing a negligible LET dependence of the tested detector. A depth dose curve was also measured by positioning the microDiamond with its main axis oriented orthogonally to the beam

  18. Quasi-steady carbon plasma source for neutral beam injector.

    Science.gov (United States)

    Koguchi, H; Sakakita, H; Kiyama, S; Shimada, T; Sato, Y; Hirano, Y

    2014-02-01

    Carbon plasma is successfully sustained during 1000 s without any carrier gas in the bucket type ionization chamber with cusp magnetic field. Every several seconds, seed plasmas having ∼3 ms duration time are injected into the ionization chamber by a shunting arch plasma gun. The weakly ionized carbon plasma ejected from the shunting arch is also ionized by 2.45 GHz microwave at the electron cyclotron resonance surface and the plasma can be sustained even in the interval of gun discharges. Control of the gun discharge interval allows to keep high pressure and to sustain the plasma for long duration.

  19. Quasi-steady carbon plasma source for neutral beam injector

    International Nuclear Information System (INIS)

    Carbon plasma is successfully sustained during 1000 s without any carrier gas in the bucket type ionization chamber with cusp magnetic field. Every several seconds, seed plasmas having ∼3 ms duration time are injected into the ionization chamber by a shunting arch plasma gun. The weakly ionized carbon plasma ejected from the shunting arch is also ionized by 2.45 GHz microwave at the electron cyclotron resonance surface and the plasma can be sustained even in the interval of gun discharges. Control of the gun discharge interval allows to keep high pressure and to sustain the plasma for long duration

  20. Quasi-steady carbon plasma source for neutral beam injector.

    Science.gov (United States)

    Koguchi, H; Sakakita, H; Kiyama, S; Shimada, T; Sato, Y; Hirano, Y

    2014-02-01

    Carbon plasma is successfully sustained during 1000 s without any carrier gas in the bucket type ionization chamber with cusp magnetic field. Every several seconds, seed plasmas having ∼3 ms duration time are injected into the ionization chamber by a shunting arch plasma gun. The weakly ionized carbon plasma ejected from the shunting arch is also ionized by 2.45 GHz microwave at the electron cyclotron resonance surface and the plasma can be sustained even in the interval of gun discharges. Control of the gun discharge interval allows to keep high pressure and to sustain the plasma for long duration. PMID:24593646

  1. Experiments with the newly available carbon beams at ISOLDE

    CERN Multimedia

    Garcia borge, M J; Koester, U H; Koldste, G T

    2002-01-01

    Recent target-ions-source developments at ISOLDE providing significantly increased yields for carbon isotopes, open up for new and intriguing experiments. We propose to exploit this in two different ways. In particular we wish to do an elastic resonance scattering experiment of $^{9}$C on a proton target to gain information on the particle unbound system $^{10}$N. Furthermore we wish to perform decay experiments of the neutron-rich carbon isotopes, with special focus on $^{17-19}$C but also including a test to see whether the even more neutron-rich isotopes $^{20,22}$C are accessible at ISOLDE.

  2. ELECTRO-THERMAL EFFECTS AND DEFORMATION RESPONSE OF CARBON FIBER MAT CEMENT BEAMS

    Institute of Scientific and Technical Information of China (English)

    ZhuSirong; LiZhuoqiu; SongXianhui

    2003-01-01

    A carbon fiber mat is a sheet composed of intercrossing short carbon fibers, which has more stable and lower electrical resistivity compared with dispersed short carbon fiber mixed in cement. Thereby carbon fiber mat cement could exhibit obvious electro-thermal effect. When electrified, the temperature of composite structures made up of cement mortar and carbon fiber mat will rise rapidly. If the temperature field is not uniform, temperature difference will cause structures to deform, which can be used to adjust the deformation of structures. The temperature field and deformation response driven by the electro-thermal effects of a type of carbon fiber mat cement beams are studied. Firstly, the temperature and deformation responses are studied using theories of thermal conduction and elasticity. Secondly, experimental results are given to verify the theoretical solution. These two parts lay the foundation for temperature and deformation adjustment.

  3. DNA damage response signaling in lung adenocarcinoma A549 cells following gamma and carbon beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Ghosh, Somnath [Radiation Biology and Health Sciences Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085 (India); Narang, Himanshi, E-mail: himinarang@gmail.com [Radiation Biology and Health Sciences Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085 (India); Sarma, Asitikantha [Radiation Biology Laboratory, Inter University Accelerator Centre, Aruna Asaf Ali Marg, New Delhi 110 067 (India); Krishna, Malini [Radiation Biology and Health Sciences Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085 (India)

    2011-11-01

    Carbon beams (5.16 MeV/u, LET = 290 keV/{mu}m) are high linear energy transfer (LET) radiation characterized by higher relative biological effectiveness than low LET radiation. The aim of the current study was to determine the signaling differences between {gamma}-rays and carbon ion-irradiation. A549 cells were irradiated with 1 Gy carbon or {gamma}-rays. Carbon beam was found to be three times more cytotoxic than {gamma}-rays despite the fact that the numbers of {gamma}-H2AX foci were same. Percentage of cells showing ATM/ATR foci were more with {gamma}-rays however number of foci per cell were more in case of carbon irradiation. Large BRCA1 foci were found in all carbon irradiated cells unlike {gamma}-rays irradiated cells and prosurvival ERK pathway was activated after {gamma}-rays irradiation but not carbon. The noteworthy finding of this study is the early phase apoptosis induction by carbon ions. In the present study in A549 lung adenocarcinoma, authors conclude that despite activation of same repair molecules such as ATM and BRCA1, differences in low and high LET damage responses might be due to their distinct macromolecular complexes rather than their individual activation and the activation of cytoplasmic pathways such as ERK, whether it applies to all the cell lines need to be further explored.

  4. Reactions of carbon atoms in pulsed molecular beams

    Energy Technology Data Exchange (ETDEWEB)

    Reisler, H. [Univ. of Southern California, Los Angeles (United States)

    1993-12-01

    This research program consists of a broad scope of experiments designed to unravel the chemistry of atomic carbon in its two spin states, P and D, by using well-controlled initial conditions and state-resolved detection of products. Prerequisite to the proposed studies (and the reason why so little is known about carbon atom reactions), is the development of clean sources of carbon atoms. Therefore, in parallel with the studies of its chemistry and reaction dynamics, the authors continuously explore new, state-specific and efficient ways of producing atomic carbon. In the current program, C({sup 3}P) is produced via laser ablation of graphite, and three areas of study are being pursued: (i) exothermic reactions with small inorganic molecules (e.g., O{sub 2}, N{sub 2}O, NO{sub 2}) that can proceed via multiple pathways; (ii) the influence of vibrational and translational energy on endothermic reactions involving H-containing reactants that yield CH products (e.g., H{sub 2}O H{sub 2}CO); (iii) reactions of C({sup 3}P) with free radicals (e.g., HCO, CH{sub 3}O). In addition, the authors plan to develop a source of C({sup 1}D) atoms by exploiting the pyrolysis of diazotetrazole and its salts in the ablation source. Another important goal involves collaboration with theoreticians in order to obtain relevant potential energy surfaces, rationalize the experimental results and predict the roles of translational and vibrational energies.

  5. Synthesis of n. c. a. PET-radiotracers with carbon-11. Zur Synthese traegerarme PET-Radiotracer mit Kohlenstoff-11

    Energy Technology Data Exchange (ETDEWEB)

    Schirbel, A.

    1998-11-01

    Carbon-11 offers the unique possibility of authentic labelling of molecules as radioindicators for non invasive and quantitative determination of physiological functions via positron emission tomography (PET). Therefore, the goal of this thesis was to synthesize of different n.c.a. [sup 11]C-labelled pharmaceuticals for in vivo distribution studies with PET. For the determination of the pharmacokinetics of [1-[sup 11]C]acetate in porcine myocardium during prolonged ischemia, n.c.a. [1-[sup 11]C]acetate was synthesized via carboxylation of methylmagnesium bromide with in target produced n.c.a. [[sup 11]C]CO[sub 2] with a radiochemical yield (RCY) of 68 [+-] 7%. The fast (18 min) and reliable radiosynthesis allowed for repeated tracer administration at short intervals (<20 min). In order to study the pharmacokinetics and metabolism of acetylsalicylic acid (Aspirin[sup R]c) in humans, [1-[sup 11]C]acetylsalicylic acid, acetyl-[carboxy-[sup 11]C]salicylic acid and [carboxy-[sup 11]C]salicylic acid were prepared. N.c.a. [1-[sup 11]C]acetylsalicylic acid was synthesized via the reaction of [1-[sup 11]C]acetylchloride with salicylic acid salts. The use of the silver salt proved to be superior to the sodium salt and resulted in radiochemical yields of 32 [+-] 5%. Base-line (clean) separation of the labelled product was achieved using radio-HPLC. With regard to the preparation of n.c.a. [carboxy-[sup 11]C]salicylic acid, several protected and unprotected phenol derivates were metallated and subsequently carboxylated using n.c.a. [[sup 11]C]CO[sub 2]. Best results (87 [+-] 3% RCY) could be achieved with 2-(methoxymethoxy)-phenylmagnesium iodide as a precursor and subsequent quantitative cleavage of the MOM-group. Acetylation of n.c.a. [carboxy-[sup 11]C]salicylic acid to acetyl-[carboxy-[sup 11]C]salicylic acid was performed using acetylchloride in CH[sub 2]Cl[sub 2] with a radiochemical yield of 65 [+-] 4%. (orig.)

  6. Interfacial electrical properties of ion-beam sputter deposited amorphous carbon on silicon

    Science.gov (United States)

    Khan, A. A.; Woollam, J. A.; Chung, Y.; Banks, B.

    1983-01-01

    Amorphous, 'diamond-like' carbon films have been deposited on Si substrates, using ion-beam sputtering. The interfacial properties are studied using capacitance and conductance measurements. Data are analyzed using existing theories for interfacial electrical properties. The density of electronic states at the interface, along with corresponding time constants are determined.

  7. Influence of electron beam irradiation on physicochemical properties of poly(trimethylene carbonate)

    NARCIS (Netherlands)

    Jozwiakowska, Joanna; Wach, Radoslaw A.; Rokita, Bozena; Ulanski, Piotr; Nalawade, Sameer P.; Grijpma, Dirk W.; Feijen, Jan; Rosiak, Janusz M.

    2011-01-01

    Electron beam (EB) irradiation of poly(trimethylene carbonate) (PTMC), an amorphous, biodegradable polymer used in the field of biomaterials, results in predominant cross-linking and finally in the formation of gel fraction, thus enabling modification of physicochemical properties of this material w

  8. Morphological and structural modifications of multiwalled carbon nanotubes by electron beam irradiation

    Science.gov (United States)

    Elsehly, Emad M.; Chechenin, N. G.; Makunin, A. V.; Motaweh, H. A.

    2016-10-01

    Effects of electron beam irradiation on a morphology and structure of multiwalled carbon nanotubes sample in a normal imaging regime of a scanning electron microscope (SEM) were investigated. Direct SEM observations give evidence that irradiation by electron beam in SEM eliminates morphological unevenness, in the form of round spots of white contrast, on the surface of carbon nanotubes (CNTs) and makes the tubes thinner. Electron dispersive analysis and Raman spectroscopy are used to explore the origin and nature of these spots. From this analysis we found that e-beam irradiation improves the CNTs graphitization. The synergy of thermal heating and ionization produced by the irradiation are discussed as possible mechanisms of the observed effects.

  9. Monte Carlo simulation of small OpenPET prototype with 11C beam irradiation: effects of secondary particles on in-beam imaging

    International Nuclear Information System (INIS)

    In-beam positron emission tomography (PET) can enable visualization of an irradiated field using positron emitters (β+ decay). In particle therapies, many kinds of secondary particles are produced by nuclear interactions, which affect PET imaging. Our purpose in this work was to evaluate effects of secondary particles on in-beam PET imaging using the Monte Carlo simulation code, Geant4, by reproducing an experiment with a small OpenPET prototype in which a PMMA phantom was irradiated by a 11C beam. The number of incident particles to the detectors and their spectra, background coincidence for the PET scan, and reconstructed images were evaluated for three periods, spill-time (beam irradiation), pause-time (accelerating the particles) and beam-off time (duration after the final spill). For spill-time, we tested a background reduction technique in which coincidence events correlated with the accelerator radiofrequency were discarded (RF gated) that has been proposed in the literature. Also, background generation processes were identified. For spill-time, most background coincidences were caused by prompt gamma rays, and only 1.4% of the total coincidences generated β+ signals. Differently, for pause-time and beam-off time, more than 75% of the total coincidence events were signals. Using these coincidence events, we failed to reconstruct images during the spill-time, but we obtained successful reconstructions for the pause-time and beam-off time, which was consistent with the experimental results. From the simulation, we found that the absence of materials in the beam line and using the RF gated technique improved the signal-to-noise ratio for the spill-time. From an additional simulation with range shifter-less irradiation and the RF gated technique, we showed the feasibility of image reconstruction during the spill-time. (paper)

  10. Making junctions between carbon nanotubes using an ion beam

    CERN Document Server

    Krasheninnikov, A V; Keinonen, J; Banhart, F

    2003-01-01

    Making use of empirical potential molecular dynamics, we study ion bombardment of crossed single-walled carbon nanotubes as a tool to join the nanotubes. We demonstrate that ion irradiation should result in welding of crossed nanotubes, both suspended and deposited on substrates. We further predict optimum ion doses and energies for ion-mediated nanotube welding which may potentially be used for developing complicated networks of joined nanotubes.

  11. The RHIC p-Carbon CNI Polarimeter Upgrade For The Beam Polarization And Intensity Measurements

    International Nuclear Information System (INIS)

    Proton polarization measurements in the AGS and RHIC (Relativistic Heavy Ion Collider at the beam energies 24-250 GeV) are based on proton-carbon and proton-proton elastic scattering in the Coulomb Nuclear Interference (CNI) region. Polarimeter operation in the scanning mode also gives polarization profile and beam intensity profile (beam emittance) measurements. Bunch by bunch emittance measurement is a very powerful tool for machine setup. Presently, the polarization and beam intensity profile measurements (in both vertical and horizontal planes) are restricted by the long target switching time and possible target destruction during this complicated motion. The RHIC polarimeters were operated near the limit of the counting rate for present silicon strip detectors. The ongoing polarimeter upgrade for the 2009 run will address all these problems. The upgrade should allow significant reduction of the polarization measurement errors by making feasible the complete polarization measurements, which includes polarization profiles in both the horizontal and vertical planes.

  12. Effect of Electron Beam Irradiation on the Tensile Properties of Carbon Nanotubes Sheets and Yarns

    Science.gov (United States)

    Williams, Tiffany S.; Miller, Sandi G.; Baker, James S.; McCorkle, Linda S.; Meador, Michael A.

    2013-01-01

    Carbon nanotube sheets and yarns were irradiated using electron beam (e-beam) energy to determine the effect of irradiation dose on the tensile properties. Results showed that a slight change in tensile strength occurred after irradiating as-received CNT sheets for 20 minutes, and a slight decrease in tensile strength as the irradiation time approached 90 minutes. On the other hand, the addition of small molecules to the CNT sheet surface had a greater effect on the tensile properties of e-beam irradiated CNT sheets. Some functionalized CNT sheets displayed up to a 57% increase in tensile strength following 90 minutes of e-beam exposure. In addition, as-received CNT yarns showed a significant increase in tensile strength as the irradiation time increased.

  13. Experimental study on fatigue crack propagation rate of RC beam strengthened with carbon fiber laminate

    Science.gov (United States)

    Huang, Peiyan; Liu, Guangwan; Guo, Xinyan; Huang, Man

    2008-11-01

    The experimental research on fatigue crack propagation rate of reinforced concrete (RC) beams strengthened with carbon fiber laminate (CFL) is carried out by MTS system in this paper. The experimental results show that, the main crack propagation on strengthened beam can be summarized into three phases: 1) fast propagation phase; 2) steady propagation and rest phase; 3) unsteady propagation phase. The phase 2-i.e. steady propagation and rest stage makes up about 95% of fatigue life of the strengthened beam. The propagation rate of the main crack, da/dN, in phase 2 can be described by Paris formula, and the constant C and m can be confirmed by the fatigue crack propagation experiments of the RC beams strengthened with CFL under three-point bending loads.

  14. Hardness and stress of amorphous carbon film deposited by glow discharge and ion beam assisting deposition

    CERN Document Server

    Marques, F C

    2000-01-01

    The hardness and stress of amorphous carbon films prepared by glow discharge and by ion beam assisting deposition are investigated. Relatively hard and almost stress free amorphous carbon films were deposited by the glow discharge technique. On the other hand, by using the ion beam assisting deposition, hard films were also obtained with a stress of the same order of those found in tetrahedral amorphous carbon films. A structural analysis indicates that all films are composed of a sp sup 2 -rich network. These results contradict the currently accepted concept that both stress and hardness are only related to the concentration of sp sup 3 sites. Furthermore, the same results also indicate that the sp sup 2 sites may also contribute to the hardness of the films.

  15. Intense heavy ion beam-induced temperature effects in carbon-based stripper foils

    International Nuclear Information System (INIS)

    At the future FAIR facility, reliably working solid carbon stripper foils are desired for providing intermediate charge states to SIS18. With the expected high beam intensities, the foils experience enhanced degradation and limited lifetime due to severe radiation damage, stress waves, and thermal effects. This work presents systematic measurements of the temperature of different carbon-based stripper foils (amorphous, diamond-like, and carbon-nanotube based) exposed to 4.8 MeV/u U, Bi, and Au beams of different pulse intensities. Thermal and spectroscopic analyses were performed by means of infrared thermography and Fourier transform infrared spectroscopy. The resulting temperature depends on the foil thickness and strongly increases with increasing pulse intensity and repetition rate. (author)

  16. Experimental studies of superhard materials carbon nitride CNx prepared by ion-beam synthesis method

    Institute of Scientific and Technical Information of China (English)

    辛火平; 林成鲁; 许华平; 邹世昌; 石晓红; 吴兴龙; 朱宏; P.L.FHemment

    1996-01-01

    Formation of superhard materials carbon nitride CNt by using ion-beam synthesis method is reported.100-keV high-dose N+ ions were implanted into carbon thin films at different temperatures.The samples were evaluated by X-ray photoelectron spectroscopy (XPS),Fourier transformation-infrared absorption spectroscopy (FTIR),Raman spectroscopy,cross-sectional transmission electron microscopy (XTEM),Rutherford backscattering spectroscopy (RBS).X-ray diffraction analysis (XRD) and Vickers microhardness measurement.The results show that the buried carbon nitride CN> layer has been successfully formed by using 100-keV high-dose N+ ions implantation into carbon thin film.Implantation of reactive ions into silicon (IRIS) computer program has been used to simulate the formation of the buried β-C3N4 layer as N+ ions are implanted into carbon.A good agreement between experimental measurements and IRIS simulation is found.

  17. Particle beam radiation therapy using carbon ions and protons for oligometastatic lung tumors

    International Nuclear Information System (INIS)

    A study was undertaken to analyze the efficacy and feasibility of particle beam radiation therapy (PBRT) using carbon ions and protons for the treatment of patients with oligometastatic lung tumors. A total of 47 patients with 59 lesions who underwent PBRT for oligometastatic lung tumors between 2003 and 2011 were included in this study. Patient median age was 66 (range, 39–84) years. The primary tumor site was the colorectum in 11 patients (23.4%), lung in 10 patients (21.3%) and a variety of other sites in 26 patients (55.3%). Thirty-one patients (66%) received chemotherapy prior to PBRT. Thirty-three lesions were treated with 320-MeV carbon ions and 26 were treated with 150- or 210-Mev protons in 1–4 portals. A median total dose of 60 (range, 52.8–70.2) GyE was delivered at the isocenter in 8 (range, 4–26) fractions. The median follow-up time was 17 months. The local control, overall survival and progression-free survival rates at 2 years were 79%, 54 and 27% respectively. PBRT-related toxicities were observed; six patients (13%) had grade 2 toxicity (including grade 2 radiation pneumonitis in 2) and six patients (13%) had grade 3 toxicity. Univariate analysis indicated that patients treated with a biologically equivalent dose of 10 (BED10) <110 GyE10, had a significantly higher local recurrence rate. Local control rates were relatively lower in the subsets of patients with the colorectum as the primary tumor site. No local progression was observed in metastases from colorectal cancer irradiated with a BED10 ≥ 110 GyE10. There was no difference in treatment results between proton and carbon ion therapy. PRBT is well tolerated and effective in the treatment of oligometastatic lung tumors. To further improve local control, high-dose PBRT with a BED10 ≥ 110 GyE10 may be promising. Further investigation of PBRT for lung oligometastases is warranted

  18. Establishment of the method for profile evaluation in matter using the therapeutic carbon pencil beam

    International Nuclear Information System (INIS)

    The scanning irradiation of the pencil beam is superior in comparison to the conventional extended-field irradiation in dose concentration. The carbon pencil beam spreads its profile in matter. The factors that cause the profile change are the nuclear fragmentation reactions and the multiple Coulomb scatterings. The fragmentation reaction is a type of nuclear reactions, where the high-energy incident particles interact with target nuclei and fragment the incident particles themselves or the target nucleus. In order to improve the accuracy of the treatment planning for the carbon beam, it is necessary to evaluate quantitatively the effect of the nuclear fragmentation reactions. The objective of this study is to establish the evaluation method for the carbon pencil beam profile in matter by selectively acquiring the nuclear fragmentation reactions and the multiple Coulomb scattering. This experiment was proposed to carry out in three years. Events with the nuclear fragmentation reactions and the multiple Coulomb scatterings were separately identified by a dedicated detector devised by our group. Profiles of these events were successfully measured. (author)

  19. Vacuum performance of a carbon fibre cryosorber for the LHC LSS beam screen

    CERN Document Server

    Anashin, V V; Dostovalov, R V; Korotaeva, Z A; Krasnov, A A; Malyshev, O B; Poluboyarov, V A

    2004-01-01

    A new carbon fibre material was developed at the Institute of Solid State Chemistry and Mechanochemistry at the Siberian Branch of the Russian Academy of Science (SB RAS) to meet the large hadron collider (LHC) vacuum chamber. The material must have a large sorbing capacity, a certain pumping speed, a working temperature range between 5 and 20K, a low activation temperature (below room temperature), a certain size in order to fit into the limited space available and it should be easy to mount. The vacuum parameters of the LHC vacuum chamber prototype with a carbon fibre cryosorber mounted onto the beam screen were studied in the beam screen temperature range from 14 to 25K at the Budker Institute of Nuclear Physics SB RAS. This carbon fibre material has shown sufficient sorption capacity for hydrogen at operational temperatures of the beam screen in the LHC long straight sections. It is also very important that this material does not crumble and makes a convenient fixation onto the beam screen in comparison t...

  20. Clinical output factors for carbon-ion beams passing through polyethylene

    CERN Document Server

    Kanematsu, Nobuyuki; Ogata, Risa; Himukai, Takeshi

    2013-01-01

    Purpose: A recent study suggested that polyethylene (PE) range compensators would cause extra carbon-ion attenuation by 0.45%/cm due to limitations in water equivalence. The present study aims to assess its influence on tumor dose in carbon-ion radiotherapy. Methods: Carbon-ion radiation was modeled to be composed of primary carbon ions and secondary particles. For these components, tumor dose fraction and relative biological effectiveness (RBE) were estimated at a reference depth in the middle of spread-out Bragg peak. The PE effect was estimated for clinical carbon-ion beams and was partially tested by experiment. The two-component model was integrated into a treatment-planning system, with which the PE effect on tumor dose was investigated in two clinical cases. Results: The fluence and clinical attenuation coefficients for dose decrease per polyethylene thickness were estimated to be 0.1%-0.3%/cm and 0.2%-0.4%/cm, depending on energy and modulation of clinical carbon-ion beams. In the treatment-planning s...

  1. Nano-structural Modification of Amorphous Carbon Thin Films by Low-energy Electron Beam Irradiation

    Institute of Scientific and Technical Information of China (English)

    EijiIwamura; MasanoriYamaguchi

    2004-01-01

    A new approach using a low-energy electron beam radiation system was investigated to synthesize carbon hybrid structures in amorphous carbon thin films. Two types of amorphous carbon films, which were 15at% iron containing film and with column/inter-column structures, were deposited onto Si substrates by a sputtering technique and subsequently exposed to an electron shower of which the energy and dose rate were much smaller compared to an intense electron beam used in a transmission electron microscopy. As a result of the low-energy and low-dose electron irradiation process, graphitic structures formed in amorphous matrix at a relatively low temperature up to 450 K. Hybrid carbon thin films containing onion-like structures in an amorphous carbon matrix were synthesized by dynamic structural modification of iron containing amorphous carbon thin films. It was found that the graphitization progressed more in the electron irradiation than in annealing at 773K, and it was attributed to thermal and catalytic effects which are strongly related to grain growth of metal clusters. On the other hand, a reversal of TEM image contrast was observed in a-C films with column/inter-column structures. It is presumed that preferable graphitization occurred in the inter-column regions induced by electron irradiation.

  2. Nano-structural Modification of Amorphous Carbon Thin Films by Low-energy Electron Beam Irradiation

    Institute of Scientific and Technical Information of China (English)

    Eiji Iwamura; Masanori Yamaguchi

    2004-01-01

    A new approach using a low-energy electron beam radiation system was investigated to synthesize carbon hybrid structures in amorphous carbon thin films. Two types of amorphous carbon films, which were 15at% iron containing film and with column/inter-column structures, were deposited onto Si substrates by a sputtering technique and subsequently exposed to an electron shower of which the energy and dose rate were much smaller compared to an intense electron beam used in a transmission electron microscopy. As a result of the low-energy and low-dose electron irradiation process,graphitic structures formed in amorphous matrix at a relatively low temperature up to 450 K. Hybrid carbon thin films containing onion-like structures in an amorphous carbon matrix were synthesized by dynamic structural modification of iron containing amorphous carbon thin films. It was found that the graphitization progressed more in the electron irradiation than in annealing at 773K, and it was attributed to thermal and catalytic effects which are strongly related to grain growth of metal clusters. On the other hand, a reversal of TEM image contrast was observed in a-C films with column/inter-column structures. It is presumed that preferable graphitization occurred in the inter-column regions induced by electron irradiation.

  3. Alanine Radiation Detectors in Therapeutic Carbon Ion Beams

    DEFF Research Database (Denmark)

    Herrmann, Rochus; Jäkel, Oliver; Palmans, Hugo;

    proportional to absorbed dose. A model by Hansen and Olsen, based on the Track Structure Theory is available, which can predict the relative efficiency of some detectors, when the particle spectrum is known. For alanine detectors the model was successfully validated by Hansen and Olsen for several ion species...... at energies below 20 MeV/u. We implemented this model in the Monte Carlo code FLUKA. At the GSI heavy ion facility in Darmstadt, Germany, alanine has been irradiated with carbon ions at energies between 88 an 400 MeV/u, which is the energy range used for therapy. The irradiation and the detector response have...... been simulated with FLUKA. We found an agreement between measured values of the relative efficiency with values predicted by the Hansen and Olsen model with divergence less than 4%. With the implementation in FLUKA we are able to simulate the detector response in the depth dose curves with precisions...

  4. The influence of lateral beam profile modifications in scanned proton and carbon ion therapy: a Monte Carlo study

    CERN Document Server

    Parodi, K; Kraemer, M; Sommerer, F; Naumann, J; Mairani, A; Brons, S

    2010-01-01

    Scanned ion beam delivery promises superior flexibility and accuracy for highly conformal tumour therapy in comparison to the usage of passive beam shaping systems. The attainable precision demands correct overlapping of the pencil-like beams which build up the entire dose distribution in the treatment field. In particular, improper dose application due to deviations of the lateral beam profiles from the nominal planning conditions must be prevented via appropriate beam monitoring in the beamline, prior to the entrance in the patient. To assess the necessary tolerance thresholds of the beam monitoring system at the Heidelberg Ion Beam Therapy Center, Germany, this study has investigated several worst-case scenarios for a sensitive treatment plan, namely scanned proton and carbon ion delivery to a small target volume at a shallow depth. Deviations from the nominal lateral beam profiles were simulated, which may occur because of misaligned elements or changes of the beam optic in the beamline. Data have been an...

  5. Electron-beam heat treatment of thin band of low-carbon steel

    International Nuclear Information System (INIS)

    Using the methods of raster electron microscopy, X-ray structural and chemical analysis and also X-ray microanalysis, the change was studied in the mechanical properies of a band made of low-carbon steel 08 kp that takes place after electron-beam heat treatment. It has been shown that the above change is due to a specific character of the α reversible γ phase transition. After electron-beam treatment under optimum conditions, the properties of the band made of steel 08 kp and 0.15 mm thick (plasticity, ultimate strength, etc.) are similar to those obtained using the conventional procedures (annealing and skin pass rolling)

  6. Deposition of diamond like carbon films by using a single ion gun with varying beam source

    Institute of Scientific and Technical Information of China (English)

    JIANG Jin-qiu; Chen Zhu-ping

    2001-01-01

    Diamond like carbon films have been successfully deposited on the steel substrate, by using a single ion gun with varying beam source. The films may appear blue, yellow and transparent in color, which was found related to contaminants from the sample holder and could be avoided. The thickness of the films ranges from tens up to 200 nanometers, and the hardness is in the range 20 to 30 GPa. Raman analytical results reveal the films are in amorphous structure. The effects of different beam source on the films structure are further discussed.

  7. Raman shift on n-doped amorphous carbon thin films grown by electron beam evaporation

    Energy Technology Data Exchange (ETDEWEB)

    Rebollo P., B. [Departamento de Fisica, Pontificia Universidad Catolica de Rio de Janeiro (Brazil); Facultad de Ciencias Fisico-Matematicas, Benemerita Universidad Autonoma de Puebla (Mexico); Freire L., F. Jr. [Departamento de Fisica, Pontificia Universidad Catolica de Rio de Janeiro (Brazil); Lozada M., R.; Palomino M., R. [Facultad de Ciencias Fisico-Matematicas, Benemerita Universidad Autonoma de Puebla (Mexico); Jimenez S., S. [Centro de Investigacion y de Estudios Avanzados del IPN, Laboratorio de Investigacion en Materiales, Queretaro (Mexico); Zelaya A., O. [Centro de Investigacion y de Estudios Avanzados del IPN, Departamento de Fisica, CINVESTAV-IPN, P.O. Box 14-740, Mexico 07360 D.F. (Mexico)

    2007-04-15

    The structural properties of carbon thin films synthesized under an atmosphere of nitrogen by means of electron beam evaporation were studied by Raman scattering spectroscopy. The electron beam evaporation technique is an important alternative to grown layers of this material with interesting structural properties. The observed shift of the Raman G band shows that the structure of the films tends to become more graphitic upon the increase of the deposition time. (copyright 2007 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  8. Production of clinically useful positron emitter beams during carbon ion deceleration

    Science.gov (United States)

    Lazzeroni, M.; Brahme, A.

    2011-03-01

    In external beam radiation therapy, radioactive beams offer the best clinical solution to simultaneously treat and in vivo monitor the dose delivery and tumor response using PET or PET-CT imaging. However, difficulties mainly linked to the low production efficiency have so far limited their use. This study is devoted to the analysis of the production of high energy 11C fragments, preferably by projectile fragmentation of a stable monodirectional and monoenergetic primary 12C beam in different absorbing materials (decelerators) in order to identify the optimal elemental composition. The study was performed using the Monte Carlo code SHIELD-HIT07. The track length and fluence of generated secondary particles were scored in a uniform absorber of 300 cm length and 10 cm radius, divided into slices of 1 cm thickness. The 11C fluence build-up and mean energy variation with increasing decelerator depth are presented. Furthermore, the fluence of the secondary 11C beam was studied as a function of its mean energy and the corresponding remaining range in water. It is shown that the maximum 11C fluence build-up is high in compounds where the fraction by weight of hydrogen is high, being the highest in liquid hydrogen. Furthermore, a cost effective alternative solution to the single medium initially envisaged is presented: a two-media decelerator that comprises a first liquid hydrogen section followed by a second decelerating section made of a hydrogen-rich material, such as polyethylene (C2H4). The purpose of the first section is to achieve a fast initial 11C fluence build-up, while the second section is primarily designed to modulate the mean energy of the generated 11C beam in order to reach the tumor depth. Finally, it was demonstrated that, if the intensity of the primary 12C beam can be increased by an order of magnitude, a sufficient intensity of the secondary 11C beam is achieved for therapy and subsequent therapeutic PET imaging sessions. Such an increase in the

  9. Charge equilibrium of a laser-generated carbon-ion beam in warm dense matter

    International Nuclear Information System (INIS)

    Using ion carbon beams generated by high intensity short pulse lasers we perform measurements of single shot mean charge equilibration in cold or isochorically heated solid density aluminum matter. We demonstrate that plasma effects in such matter heated up to 1 eV do not significantly impact the equilibration of carbon ions with energies 0.045-0.5 MeV/nucleon. Furthermore, these measurements allow for a first evaluation of semiempirical formulas or ab initio models that are being used to predict the mean of the equilibrium charge state distribution for light ions passing through warm dense matter. (authors)

  10. Tribological properties of ion beam deposited diamond-like carbon film on silicon nitride

    International Nuclear Information System (INIS)

    The present article reports on the physical characterization and tribological properties of diamond-like carbon (DLC) films deposited on structural Si3N4 substrates. The films were deposited by the direct ion beam deposition technique. The ion beam was produced by plasma discharge of pre-mixed methane and hydrogen gas in a Kaufman-type ion source. The deposited films were found to be amorphous and contained about 70% carbon and 30% hydrogen. The friction coefficient of an uncoated Si3N4 ball on a DLC coated Si3N4 disc starts at about 0.2, then decreases rapidly to 0.1-0.15 with increasing sliding distance. Increasing humidity results in a slight increase in friction coefficient, but a significant decrease in wear factor. The wear factor for the tests at ≅60% rh (relative humidity) are about an order of magnitude smaller than the tests at 3% rh. (orig.)

  11. Radiological characteristics of MRI-based VIP polymer gel under carbon beam irradiation

    Science.gov (United States)

    Maeyama, T.; Fukunishi, N.; Ishikawa, K. L.; Furuta, T.; Fukasaku, K.; Takagi, S.; Noda, S.; Himeno, R.; Fukuda, S.

    2015-02-01

    We study the radiological characteristics of VIP polymer gel dosimeters under carbon beam irradiation with energy of 135 and 290 AMeV. To evaluate dose response of VIP polymer gels, the transverse (or spin-spin) relaxation rate R2 of the dosimeters measured by magnetic resonance imaging (MRI) as a function of linear energy transfer (LET), rather than penetration depth, as is usually done in previous reports. LET is evaluated by use of the particle transport simulation code PHITS. Our results reveal that the dose response decreases with increasing dose-averaged LET and that the dose response-LET relation also varies with incident carbon beam energy. The latter can be explained by taking into account the contribution from fragmentation products.

  12. Two Types of Mass Abundance Distributions for Anionic Carbon Clusters Investigated by Laser Vaporization and Pulsed Molecular Beam Techniques

    Institute of Scientific and Technical Information of China (English)

    ZHAI Hua-Jin; LIU Bing-Chen; NI Guo-Quan; XUZhi-Zhan

    2000-01-01

    Two types of mass spectra for anionic carbon clusters Cn- have been revealed using laser vaporization and pulsed molecular beam techniques. The less structured mass spectrum characteristic of the magic-numbers at n = 5, 8,11, 15, and 17 is established at the early stage of the cluster formation process, namely, in the laser vaporization process. The more structured one is featured for a regular odd-even alternation and the magic numbers at n =10, 12, 16, 18, 22, and 28, and has been developed only after extensive clustering and qnenching processes, where low-energy electron attachment plays a vital role. Transition between these two types of mass spectra can be realized by controlling either the strength of the pulsed gas flow or the synchronism between the gas flow and the laser vaporization.

  13. Consumption of carbon fiber plates in the reinforced concrete beams strengthened with CFPs

    Institute of Scientific and Technical Information of China (English)

    BU Liangtao; SONG Li; SHI Chuxian

    2007-01-01

    Four-point bending flexural tests were conducted to one full-size reinforced concrete (RC) beam and three full-size RC beams strengthened with carbon fiber plates (CFPs).The experimental results showed that the consumption of CFP had significant effects on failure modes and the flexural capacity.An analytical procedure,based on the limit failure ode and ductility,was presented to predict the applied area of CFP.An analytical program,based on Smith-Teng model and Cheng-Teng model,was provided to calculate the bonding length of CFP.The test results are used to validate the proposed procedure.The results are also applied to the design and construction of RC beam strengthened with CFP.

  14. Synthesis and electrochemical capacitive properties of nitrogen-doped porous carbon micropolyhedra by direct carbonization of zeolitic imidazolate framework-11

    Energy Technology Data Exchange (ETDEWEB)

    Hao, Fei; Li, Li; Zhang, Xiaohua, E-mail: mickyxie@hnu.edu.cn; Chen, Jinhua, E-mail: chenjinhua@hnu.edu.cn

    2015-06-15

    Highlights: • Nitrogen-doped porous carbon micropolyhedra (N-PCMPs) were prepared from ZIF-11. • The activated N-PCMPs with fused KOH (N-PCMPs-A) have high specific surface area. • N-PCMPs-A exhibits high specific capacitance. • N-PCMPs-A reveals good cycling performance even at a high current density. - Abstract: Nitrogen-doped porous carbon micropolyhedra (N-PCMPs) were successfully prepared by direct carbonization of ZIF-11 polyhedra and further activated with fused KOH to obtain N-PCMPs-A. The morphology and microstructure of samples were examined by scanning electron microscopy, X-ray diffraction, and micropore and chemisorption analyzer. Electrochemical properties were characterized by cyclic voltammetry and galvanostatic charge/discharge method in 1.0 M H{sub 2}SO{sub 4} aqueous solution on a standard three-electrode system. Results show that, compared with N-PCMPs, N-PCMPs-A has higher specific surface area (2188 m{sup 2} g{sup −1}) and exhibits improved electrochemical capacitive properties (307 F g{sup −1} at 1.0 A g{sup −1}). The mass specific capacitance of N-PCMPs-A is also higher than that of most MOF-derived carbons, some carbide-derived carbons and carbon aerogel-derived carbons. In addition, the capacitance of the N-PCMPs-A retains 90% after 4000 cycles even at a high current density of 10 A g{sup −1}. These imply that N-PCMPs-A is the promising materials for the construction of a high-performance supercapacitor.

  15. Synthesis and electrochemical capacitive properties of nitrogen-doped porous carbon micropolyhedra by direct carbonization of zeolitic imidazolate framework-11

    International Nuclear Information System (INIS)

    Highlights: • Nitrogen-doped porous carbon micropolyhedra (N-PCMPs) were prepared from ZIF-11. • The activated N-PCMPs with fused KOH (N-PCMPs-A) have high specific surface area. • N-PCMPs-A exhibits high specific capacitance. • N-PCMPs-A reveals good cycling performance even at a high current density. - Abstract: Nitrogen-doped porous carbon micropolyhedra (N-PCMPs) were successfully prepared by direct carbonization of ZIF-11 polyhedra and further activated with fused KOH to obtain N-PCMPs-A. The morphology and microstructure of samples were examined by scanning electron microscopy, X-ray diffraction, and micropore and chemisorption analyzer. Electrochemical properties were characterized by cyclic voltammetry and galvanostatic charge/discharge method in 1.0 M H2SO4 aqueous solution on a standard three-electrode system. Results show that, compared with N-PCMPs, N-PCMPs-A has higher specific surface area (2188 m2 g−1) and exhibits improved electrochemical capacitive properties (307 F g−1 at 1.0 A g−1). The mass specific capacitance of N-PCMPs-A is also higher than that of most MOF-derived carbons, some carbide-derived carbons and carbon aerogel-derived carbons. In addition, the capacitance of the N-PCMPs-A retains 90% after 4000 cycles even at a high current density of 10 A g−1. These imply that N-PCMPs-A is the promising materials for the construction of a high-performance supercapacitor

  16. Study the structure of neutron deficient carbon isotopes: 10C and 11C. Elastic and inelastic scattering on proton target

    International Nuclear Information System (INIS)

    This work is devoted to the study of the structure of neutron-deficient carbon isotopes: 10C and 11C. A theoretical model predicts a special behaviour for these nuclei: different deformations for neutron and proton densities. To test these predictions and to obtain information on the structure of these nuclei, we measured angular distribution for elastic and inelastic scattering on proton target with inverse kinematics at 40 MeV per nucleon. The angular distribution is deduced from the proton energy and angle scattering, measured by the MUST detector. Experimental set-up is completed with plastic detectors for scattered nucleus identification and with two CATS detectors for measurement of position and angle for each beam particle on the target. Angular distributions are calculated with an analytic method. This method is tested with a simulation and with 12C + p scattering analysis. Angular distributions are analysed in terms of a complex microscopic potential JLM with different microscopic matter densities. Elastic scattering gives an information on 10C and 11C matter root mean square radii. Both radii are larger than the one for the stable 12C isotope. Inelastic scattering is treated in DWBA approximation with microscopic transition densities. 10C inelastic scattering gives an information on neutron contribution of nucleus excitation. With 11C inelastic scattering, we could constrain transition densities and we could extract an information on the type of the transition. However, it is very difficult to confirm or to annul predictions of different deformations for proton and neutrons densities. (author)

  17. Characterization of polyacrylonitrile based carbon nanofiber mats via electron beam processing.

    Science.gov (United States)

    Kim, Du-Yeong; Shin, Hye-Kyoung; Jeun, Joon-Pyo; Kim, Hyun-Bin; Oh, Seung-Hwan; Kang, Phil-Hyun

    2012-07-01

    The aim of this study was to evaluate the ability of electron beam irradiation to drive stabilization reactions within PAN nanofiber mats to obtain carbon nanofiber mats. PAN nanofiber mats with fiber diameters of 300-400 nm were prepared via an electrospinning method. Electrospun PAN nanofiber mats were stabilized by electron beam irradiation with various doses up to 5,000 kGy. Using the irradiation-stabilized PAN nanofiber mats, carbon nanofibers were obtained by pyrolysis in a tube furnace for 1 h at 1,000 degrees C under an N2 atmosphere. FT-IR analysis indicated that the transformation of C[triple bond]N groups to C==N groups was accelerated by electron beam stabilization. The thermal behavior of the PAN nanofiber mats was studied using DSC and TGA. DSC thermograms showed that the peak temperatures of the exothermic reactions were found to decrease with increasing electron beam irradiation doses. Irradiation-stabilized PAN nanofiber mats were not observed to dramatically decrease in weight between 290 degrees C and 320 degrees C, an observation presumed to be related to cyclization. The char yields of PAN were found to increase with increasing irradiation doses. PMID:22966719

  18. Mutagenic effects of carbon ion beam irradiations on dry Lotus japonicus seeds

    Science.gov (United States)

    Luo, Shanwei; Zhou, Libin; Li, Wenjian; Du, Yan; Yu, Lixia; Feng, Hui; Mu, Jinhu; Chen, Yuze

    2016-09-01

    Carbon ion beam irradiation is a powerful method for creating mutants and has been used in crop breeding more and more. To investigate the effects of carbon ion beams on Lotus japonicus, dry seeds were irradiated by 80 MeV/u carbon ion beam at dosages of 0, 100, 200, 300, 400, 500 and 600 Gy. The germination rate, survival rate and root length of M1 populations were explored and the dose of 400 Gy was selected as the median lethal dose (LD50) for a large-scale mutant screening. Among 2472 M2 plants, 127 morphological mutants including leaf, stem, flower and fruit phenotypic variation were found, and the mutation frequency was approximately 5.14%. Inter simple sequence repeat (ISSR) assays were utilized to investigate the DNA polymorphism between seven mutants and eight plants without phenotypic variation from M2 populations. No remarkable differences were detected between these two groups, and the total polymorphic rate was 0.567%.

  19. Electrochemical impedance spectroscopy on nanostructured carbon electrodes grown by supersonic cluster beam deposition

    Energy Technology Data Exchange (ETDEWEB)

    Bettini, Luca Giacomo; Bardizza, Giorgio; Podesta, Alessandro; Milani, Paolo; Piseri, Paolo, E-mail: piseri@mi.infn.it [Universita degli Studi di Milano, Dipartimento di Fisica and CIMaINa (Italy)

    2013-02-15

    Nanostructured porous films of carbon with density of about 0.5 g/cm{sup 3} and 200 nm thickness were deposited at room temperature by supersonic cluster beam deposition (SCBD) from carbon clusters formed in the gas phase. Carbon film surface topography, determined by atomic force microscopy, reveals a surface roughness of 16 nm and a granular morphology arising from the low kinetic energy ballistic deposition regime. The material is characterized by a highly disordered carbon structure with predominant sp2 hybridization as evidenced by Raman spectroscopy. The interface properties of nanostructured carbon electrodes were investigated by cyclic voltammetry and electrochemical impedance spectroscopy employing KOH 1 M solution as aqueous electrolyte. An increase of the double layer capacitance is observed when the electrodes are heat treated in air or when a nanostructured nickel layer deposited by SCBD on top of a sputter deposited film of the same metal is employed as a current collector instead of a plain metallic film. This enhancement is consistent with an improved charge injection in the active material and is ascribed to the modification of the electrical contact at the interface between the carbon and the metal current collector. Specific capacitance values up to 120 F/g have been measured for the electrodes with nanostructured metal/carbon interface.

  20. A quartz-lined carbon-11 target: striving for increased yield and specific activity

    DEFF Research Database (Denmark)

    Koziorowski, Jacek; Larsen, Peter; Gillings, Nic

    2010-01-01

    The increased demand for high specific radioactivity neuroreceptor ligands for positron emission tomography (PET) requires the production of high specific radioactivity carbon-11 in high yields. We have attempted to address this issue with the development of a new quartz-lined aluminium target fo...

  1. Focused-electron-beam-induced processing (FEBIP) for emerging applications in carbon nanoelectronics

    International Nuclear Information System (INIS)

    Focused-electron-beam-induced processing (FEBIP), a resist-free additive nanomanufacturing technique, is an actively researched method for ''direct-write'' processing of a wide range of structural and functional nanomaterials, with high degree of spatial and time-domain control. This article attempts to critically assess the FEBIP capabilities and unique value proposition in the context of processing of electronics materials, with a particular emphasis on emerging carbon (i.e., based on graphene and carbon nanotubes) devices and interconnect structures. One of the major hurdles in advancing the carbon-based electronic materials and device fabrication is a disjoint nature of various processing steps involved in making a functional device from the precursor graphene/CNT materials. Not only this multi-step sequence severely limits the throughput and increases the cost, but also dramatically reduces the processing reproducibility and negatively impacts the quality because of possible between-the-step contamination, especially for impurity-susceptible materials such as graphene. The FEBIP provides a unique opportunity to address many challenges of carbon nanoelectronics, especially when it is employed as part of an integrated processing environment based on multiple ''beams'' of energetic particles, including electrons, photons, and molecules. This avenue is promising from the applications' prospective, as such a multi-functional (electron/photon/molecule beam) enables one to define shapes (patterning), form structures (deposition/etching), and modify (cleaning/doping/annealing) properties with locally resolved control on nanoscale using the same tool without ever changing the processing environment. It thus will have a direct positive impact on enhancing functionality, improving quality and reducing fabrication costs for electronic devices, based on both conventional CMOS and emerging carbon (CNT/graphene) materials. (orig.)

  2. Focused-electron-beam-induced processing (FEBIP) for emerging applications in carbon nanoelectronics

    Science.gov (United States)

    Fedorov, Andrei G.; Kim, Songkil; Henry, Mathias; Kulkarni, Dhaval; Tsukruk, Vladimir V.

    2014-12-01

    Focused-electron-beam-induced processing (FEBIP), a resist-free additive nanomanufacturing technique, is an actively researched method for "direct-write" processing of a wide range of structural and functional nanomaterials, with high degree of spatial and time-domain control. This article attempts to critically assess the FEBIP capabilities and unique value proposition in the context of processing of electronics materials, with a particular emphasis on emerging carbon (i.e., based on graphene and carbon nanotubes) devices and interconnect structures. One of the major hurdles in advancing the carbon-based electronic materials and device fabrication is a disjoint nature of various processing steps involved in making a functional device from the precursor graphene/CNT materials. Not only this multi-step sequence severely limits the throughput and increases the cost, but also dramatically reduces the processing reproducibility and negatively impacts the quality because of possible between-the-step contamination, especially for impurity-susceptible materials such as graphene. The FEBIP provides a unique opportunity to address many challenges of carbon nanoelectronics, especially when it is employed as part of an integrated processing environment based on multiple "beams" of energetic particles, including electrons, photons, and molecules. This avenue is promising from the applications' prospective, as such a multi-functional (electron/photon/molecule beam) enables one to define shapes (patterning), form structures (deposition/etching), and modify (cleaning/doping/annealing) properties with locally resolved control on nanoscale using the same tool without ever changing the processing environment. It thus will have a direct positive impact on enhancing functionality, improving quality and reducing fabrication costs for electronic devices, based on both conventional CMOS and emerging carbon (CNT/graphene) materials.

  3. Tilting of carbon encapsulated metallic nanocolumns in carbon-nickel nanocomposite films by ion beam assisted deposition

    Energy Technology Data Exchange (ETDEWEB)

    Krause, Matthias [Helmholtz-Zentrum Dresden-Rossendorf, PF-510119, 01314 Dresden (Germany); Technische Universitaet Dresden, D-01062 Dresden (Germany); Muecklich, Arndt; Zschornak, Matthias; Wintz, Sebastian; Gemming, Sibylle; Abrasonis, Gintautas [Helmholtz-Zentrum Dresden-Rossendorf, PF-510119, 01314 Dresden (Germany); Oates, Thomas W. H. [Leibniz-Institut fuer Analytische Wissenschaft, ISAS e.V., Albert-Einstein-Str. 9, 12489 Berlin (Germany); Luis Endrino, Jose [Surfaces and Coatings Department, Instituto de Ciencia de Materiales de Madrid, c/Sor Juana Ines de la Cruz 3, Cantoblanco, 28049 Madrid (Spain); Baehtz, Carsten; Shalimov, Artem [Helmholtz-Zentrum Dresden-Rossendorf, PF-510119, 01314 Dresden (Germany); Rossendorf Beamline, European Synchrotron Radiation Facility, F-38043 Grenoble (France)

    2012-07-30

    The influence of assisting low-energy ({approx}50-100 eV) ion irradiation effects on the morphology of C:Ni ({approx}15 at. %) nanocomposite films during ion beam assisted deposition (IBAD) is investigated. It is shown that IBAD promotes the columnar growth of carbon encapsulated metallic nanoparticles. The momentum transfer from assisting ions results in tilting of the columns in relation to the growing film surface. Complex secondary structures are obtained, in which a significant part of the columns grows under local epitaxy via the junction of sequentially deposited thin film fractions. The influence of such anisotropic film morphology on the optical properties is highlighted.

  4. Reinforced concrete beams strengthened with carbon fiber reinforced polymer by friction hybrid bond technique: Experimental investigation

    International Nuclear Information System (INIS)

    Highlights: • Friction Hybrid Bonded FRP Technique is conducted to strengthen RC beams. • Six specimens with different reinforced methods were tested. • The strengthened effects of different strengthening methods were discussed. • The results obtained from the FEA and experiments are agreed very well. - Abstract: Carbon fiber reinforced polymer (CFRP) can be used to strengthen the reinforced concrete (RC) beams. But premature debonding is the main failure model in ordinary bond technique, and the strengthening effect is limited. In order to improve bonding and restricting sliding displacement, Friction Hybrid Bonded FRP Technique (FHB-FRP) is developed. Six simple-span RC specimen beams with different strengthened methods were tested in four-point bending. The experiment results indicate that FRP debonding can be effectively prevented by the FHB-FRP strengthened beam. The ultimate load-carrying capacity of the specimen strengthened by FHB-FRP technique is able to increase by a factor of 2.13 times compared with the beam strengthened with ordinary bond technique (U-jacketing technique). In addition, the cracking and yielding loads are improved more significantly by FHB-FRP technique than U-jacketing technique. Specimens strengthened with FHB-FRP technique have cracks with a more limited distribution and width. Finally, the finite element method (FEM) is conducted to simulate the behavior of the test specimens. The results obtained from the finite element method are compared with experiment. Excellent agreements have been achieved in the comparison of results

  5. Dosimetric characterization and application of an imaging beam line with a carbon electron target for megavoltage cone beam computed tomography.

    Science.gov (United States)

    Flynn, Ryan T; Hartmann, Julia; Bani-Hashemi, Ali; Nixon, Earl; Alfredo, R; Siochi, C; Pennington, Edward C; Bayouth, John E

    2009-06-01

    Imaging dose from megavoltage cone beam computed tomography (MVCBCT) can be significantly reduced without loss of image quality by using an imaging beam line (IBL), with no flattening filter and a carbon, rather than tungsten, electron target. The IBL produces a greater keV-range x-ray fluence than the treatment beam line (TBL), which results in a more optimal detector response. The IBL imaging dose is not necessarily negligible, however. In this work an IBL was dosimetrically modeled with the Philips Pinnacle3 treatment planning system (TPS), verified experimentally, and applied to clinical cases. The IBL acquisition dose for a 200 degrees gantry rotation was verified in a customized acrylic cylindrical phantom at multiple imaging field sizes with 196 ion chamber measurements. Agreement between the measured and calculated IBL dose was quantified with the 3D gamma index. Representative IBL and TBL imaging dose distributions were calculated for head and neck and prostate patients and included in treatment plans using the imaging dose incorporation (IDI) method. Surface dose was measured for the TBL and IBL for four head and neck cancer patients with MOSFETs. The IBL model, when compared to the percentage depth dose and profile measurements, had 97% passing gamma indices for dosimetric and distance acceptance criteria of 3%, 3 mm, and 100% passed for 5.2%, 5.2 mm. For the ion chamber measurements of phantom image acquisition dose, the IBL model had 93% passing gamma indices for acceptance criteria of 3%, 3 mm, and 100% passed for 4%, 4 mm. Differences between the IBL- and TBL-based IMRT treatment plans created with the IDI method were dosimetrically insignificant for both the prostate and head and neck cases. For IBL and TBL beams with monitor unit values that would result in the delivery of the same dose to the depth of maximum dose under standard calibration conditions, the IBL imaging surface dose was higher than the TBL imaging surface dose by an average of 18

  6. Measurement of characteristic prompt gamma rays emitted from oxygen and carbon in tissue-equivalent samples during proton beam irradiation

    OpenAIRE

    Polf, Jerimy C.; Panthi, Rajesh; Mackin, Dennis S; McCleskey, Matt; Saastamoinen, Antti; Roeder, Brian T; Beddar, Sam

    2013-01-01

    The purpose of this work was to characterize how prompt gamma (PG) emission from tissue changes as a function of carbon and oxygen concentration, and to assess the feasibility of determining elemental concentration in tissues irradiated with proton beams. For this study, four tissue-equivalent water-sucrose samples with differing densities and concentrations of carbon, hydrogen, and oxygen were irradiated with a 48 MeV proton pencil beam. The PG spectrum emitted from each sample was measured ...

  7. Synthesis of carbon-11, fluorine-18, and nitrogen-13 labeled radiotracers for biomedical applications

    Energy Technology Data Exchange (ETDEWEB)

    Fowler, J.S.; Wolf, A.P.

    1981-01-01

    A number of reviews, many of them recent, have appeared on various aspects of /sup 11/C, /sup 18/F and /sup 13/N-labeled radiotracers. This monograph treats the topic principally from the standpoint of synthetic organic chemistry while keeping in perspective the necessity of integrating the organic chemistry with the design and ultimate application of the radiotracer. Where possible, recent examples from the literature of organic synthesis are introduced to suggest potentially new routes which may be applied to problems in labeling organic molecules with the short-lived positron emitters, carbon-11, fluorine-18, and nitrogen-13. The literature survey of carbon-11, fluorine-18 and nitrogen-13 labeled compounds presented are of particular value to scientists working in this field. Two appendices are also included to provide supplementary general references. A subject index concludes this volume.

  8. Synthesis of carbon-11, fluorine-18, and nitrogen-13 labeled radiotracers for biomedical applications

    International Nuclear Information System (INIS)

    A number of reviews, many of them recent, have appeared on various aspects of 11C, 18F and 13N-labeled radiotracers. This monograph treats the topic principally from the standpoint of synthetic organic chemistry while keeping in perspective the necessity of integrating the organic chemistry with the design and ultimate application of the radiotracer. Where possible, recent examples from the literature of organic synthesis are introduced to suggest potentially new routes which may be applied to problems in labeling organic molecules with the short-lived positron emitters, carbon-11, fluorine-18, and nitrogen-13. The literature survey of carbon-11, fluorine-18 and nitrogen-13 labeled compounds presented are of particular value to scientists working in this field. Two appendices are also included to provide supplementary general references. A subject index concludes this volume

  9. Finite Element Modeling and Free Vibration Analysis of Functionally Graded Nanocomposite Beams Reinforced by Randomly Oriented Carbon Nanotubes

    Directory of Open Access Journals (Sweden)

    Benedict Thomas

    2013-12-01

    Full Text Available This article deals with the finite element modeling and free vibration analysis of functionally graded nanocomposite beams reinforced by randomly oriented straight single-walled carbon nanotubes (SWCNTs. Nanostructural materials can be used to alter mechanical, thermal and electrical properties of polymer-based composite materials, because of their superior properties and perfect atom arrangement. Timoshenko beam theory is used to evaluate dynamic characteristics of the beam. The Eshelby–Mori–Tanaka approach based on an equivalent fiber is used to investigate the material properties of the beam. The equations of motion are derived by using Hamilton’s principle. The finite element method is employed to discretize the model and obtain a numerical approximation of the motion equation. Different SWCNTs distributions in the thickness direction are introduced to improve fundamental natural frequency and dynamic behavior of uniform functionally graded nanocomposite beam. Results are presented in tabular and graphical forms to show the effects of various material distributions, carbon nanotube orientations, shear deformation, slenderness ratios and boundary conditions on the dynamic behavior of the beam. The first five normalized mode shapes for functionally graded carbon nanotube reinforced composite (FG-CNTRC beams with different boundary conditions and different carbon nanotubes (CNTs orientation are presented. The results show that the above mentioned effects play very important role on the dynamic behavior of the beam.

  10. Carbon doping in molecular beam epitaxy of GaAs from a heated graphite filament

    Science.gov (United States)

    Malik, R. J.; Nottenberg, R. N.; Schubert, E. F.; Walker, J. F.; Ryan, R. W.

    1988-01-01

    Carbon doping of GaAs grown by molecular beam epitaxy has been obtained for the first time by use of a heated graphite filament. Controlled carbon acceptor concentrations over the range of 10 to the 17th-10 to the 20th/cu cm were achieved by resistively heating a graphite filament with a direct current power supply. Capacitance-voltage, p/n junction and secondary-ion mass spectrometry measurements indicate that there is negligible diffusion of carbon during growth and with postgrowth rapid thermal annealing. Carbon was used for p-type doping in the base of Npn AlGaAs/GaAs heterojunction bipolar transistors. Current gains greater than 100 and near-ideal emitter heterojunctions were obtained in transistors with a carbon base doping of 1 x 10 to the 19th/cu cm. These preliminary results indicate that carbon doping from a solid graphite source may be an attractive substitute for beryllium, which is known to have a relatively high diffusion coefficient in GaAs.

  11. Localized surface grafting reactions on carbon nanofibers induced by gamma and e-beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Evora, M.C., E-mail: cecilia@ieav.cta.br [Institute for Advanced Studies-IEAV/DCTA, Av. Cel Jose Alberto Albano do Amarante, 1-Putim, 12228-001 São Jose dos Campos, SP (Brazil); Araujo, J.R., E-mail: jraraujo@inmetro.gov.br [Instituto Nacional de Metrologia, Qualidade e Tecnologia, Av. Nossa Sra. das Graças, 50, 25250-020 Duque de Caxias, RJ (Brazil); Ferreira, E.H.M. [Instituto Nacional de Metrologia, Qualidade e Tecnologia, Av. Nossa Sra. das Graças, 50, 25250-020 Duque de Caxias, RJ (Brazil); Strohmeier, B.R. [Thermo Fisher Scientific, 5225 Verona Road, Madison, WI 53711 (United States); Silva, L.G.A., E-mail: lgasilva@ipen.br [Institute for Nuclear and Energy Research- IPEN, Av. Prof lineu Prestes, 2242- Cidade Universitaria, 05508-000 SP (Brazil); Achete, C.A. [Instituto Nacional de Metrologia, Qualidade e Tecnologia, Av. Nossa Sra. das Graças, 50, 25250-020 Duque de Caxias, RJ (Brazil)

    2015-04-30

    Graphical abstract: - Highlights: • Methodology for the functionalization of carbon nanofibers was investigated. • Two radiation sources were used to promote grafting reactions: gamma and electron beam. • We report the optimum inhibitor concentration to achieve the functionalization. • Surface of carbon nanofibers showed an increase of oxygen content after irradiation. • The radiation-induced graphitization did not damage the overall sp{sup 2} structure. - Abstract: Electron beam and gamma-ray irradiation have potential application to modify the carbon fiber nanostructures in order to produce useful defects in the graphitic structure and create reactive sites. In this study, the methodology to functionalize carbon nanofiber (CNF), via a radiation process and using acrylic acid as a source of oxygen functional groups, was investigated. The samples were submitted to a direct grafting radiation process with electron beam and gamma-ray source. Several parameters were changed such as: acrylic acid concentration, radiation dose and percentage of inhibitor necessary to achieve functionalization, with higher percentage of oxygen functional groups on CNF surface, and better dispersion. The better results achieved were when mixing CNF in a solution of acrylic acid with 6% of inhibitor (FeSO{sub 4}·7H{sub 2}O) and irradiated at 100 kGy. The samples were characterized by X-ray photoelectron spectroscopy and the surface composition (atomic%) showed a significant increase of oxygen content for the samples after irradiation. Also, the dispersion of the functionalized CNF in water was stable during months which may be a good indication that the functionalization process of CNF via ionizing radiation was successful.

  12. Measurement of regional pulmonary function with carbon-11-labeled CO2 and CO

    International Nuclear Information System (INIS)

    Carbon dioxide and carbon monoxide labelled with carbon-11 have been produced in the remotecontrolled system for a large scale production of short lived radioactive substance with cyclotron in National Institute of Radiological Sciences. The single breath measurement with 11CO2 and 11CO, using inhalation system and a coincidence positron camera combined with an on-line computer system (TOSBAC 3400 Model 31) has been employed to evaluate regional pulmonary blood flow and diffusing capacity in three normal volunteers and seven patients with chronic obstructive pulmonary disease (COPD), old lung tuberculosis and benign tumor. Regional clearance rate constant (lambda) and distribution index (lambda i/lambda t) were calculated from monoexponential removal curves measured by external counting over the chest in supine position. This process was performed in a short period of breath-holding (10 - 20 sec.) after a single breath of these radioactive gases mixed with room air. These parameters were calculated for each lung fields divided into four zones (bilateral upper and lower lung region). In our method, the activity of the inspired mixture were 5 - 35 mCi/L and each value in lung fields, divided into four zones, can be measured with time interval for one second. While the clearance rate of 11CO2 seemed to be mainly limited by pulmonary blood flow, it was considered that the rate of 11CO were limited by not only the diffusing capacity but also the perfusion in each lung fields. In normal subjects, the distribution of regional clearance rate was showed approximately even for 11CO2 and 11CO. It was caused of the measurement in supine position. In contrast, the distribution of these parameter was showed uneven in patients with lung disease, particularly with COPD. (author)

  13. Carbon-11 radiolabeling of iron-oxide nanoparticles for dual-modality PET/MR imaging

    Science.gov (United States)

    Sharma, Ramesh; Xu, Youwen; Kim, Sung Won; Schueller, Michael J.; Alexoff, David; Smith, S. David; Wang, Wei; Schlyer, David

    2013-07-01

    Dual-modality imaging, using Magnetic Resonance Imaging (MRI) and Positron Emission Tomography (PET) simultaneously, is a powerful tool to gain valuable information correlating structure with function in biomedicine. The advantage of this dual approach is that the strengths of one modality can balance the weaknesses of the other. However, success of this technique requires developing imaging probes suitable for both. Here, we report on the development of a nanoparticle labeling procedure via covalent bonding with carbon-11 PET isotope. Carbon-11 in the form of [11C]methyl iodide was used as a methylation agent to react with carboxylic acid (-COOH) and amine (-NH2) functional groups of ligands bound to the nanoparticles (NPs). The surface coating ligands present on superparamagnetic iron-oxide nanoparticles (SPIO NPs) were radiolabeled to achieve dual-modality PET/MR imaging capabilities. The proof-of-concept dual-modality PET/MR imaging using the radiolabeled SPIO NPs was demonstrated in an in vivo experiment.Dual-modality imaging, using Magnetic Resonance Imaging (MRI) and Positron Emission Tomography (PET) simultaneously, is a powerful tool to gain valuable information correlating structure with function in biomedicine. The advantage of this dual approach is that the strengths of one modality can balance the weaknesses of the other. However, success of this technique requires developing imaging probes suitable for both. Here, we report on the development of a nanoparticle labeling procedure via covalent bonding with carbon-11 PET isotope. Carbon-11 in the form of [11C]methyl iodide was used as a methylation agent to react with carboxylic acid (-COOH) and amine (-NH2) functional groups of ligands bound to the nanoparticles (NPs). The surface coating ligands present on superparamagnetic iron-oxide nanoparticles (SPIO NPs) were radiolabeled to achieve dual-modality PET/MR imaging capabilities. The proof-of-concept dual-modality PET/MR imaging using the radiolabeled

  14. Measurement of analyzing powers of π+ and π- produced on a hydrogen and a carbon target with a 22-GeV/c incident polarized proton beam

    International Nuclear Information System (INIS)

    The analyzing powers of π+ and π- were measured using an incident 22-GeV/c transversely polarized proton beam at the Brookhaven Alternating Gradient Synchrotron. A magnetic spectrometer measured π± inclusive asymmetries on a hydrogen and a carbon target. An elastic polarimeter with a CH2 target measured pp elastic-scattering asymmetries to determine the beam polarization using published data for the pp elastic analyzing power. Using the beam polarization determined from the elastic polarimeter and asymmetries from the inclusive spectrometer, analyzing powers AN for π± were determined in the xF and pT ranges (0.45-0.8) and (0.3-1.2 GeV/c), respectively. The analyzing power results are similar in both sign and character to other measurements at 200 and 11.7 GeV/c, confirming the expectation that high-energy pion inclusive analyzing powers remain large and relatively energy independent. This suggests that pion inclusive polarimetry may be a suitable method for measuring future beam polarizations at BNL RHIC or DESY HERA. Analyzing powers of π+ and π- produced on hydrogen and carbon targets are the same. Various models to explain inclusive analyzing powers are also discussed

  15. Charged particle's flux measurement from PMMA irradiated by 80 MeV/u carbon ion beam

    CERN Document Server

    Agodi, C; Bellini, F; Cirrone, G A P; Collamati, F; Cuttone, G; De Lucia, E; De Napoli, M; Di Domenico, A; Faccini, R; Ferroni, F; Fiore, S; Gauzzi, P; Iarocci, E; Marafini, M; Mattei, I; Muraro, S; Paoloni, A; Patera, V; Piersanti, L; Romano, F; Sarti, A; Sciubba, A; Vitale, E; Voena, C

    2012-01-01

    Hadrontherapy is an emerging technique in cancer therapy that uses beams of charged particles. To meet the improved capability of hadrontherapy in matching the dose release with the cancer position, new dose monitoring techniques need to be developed and introduced into clinical use. The measurement of the fluxes of the secondary particles produced by the hadron beam is of fundamental importance in the design of any dose monitoring device and is eagerly needed to tune Monte Carlo simulations. We report the measurements done with charged secondary particles produced from the interaction of a 80 MeV/u fully stripped carbon ion beam at the INFN Laboratori Nazionali del Sud, Catania, with a Poly-methyl methacrylate target. Charged secondary particles, produced at 90$\\degree$ with respect to the beam axis, have been tracked with a drift chamber, while their energy and time of flight has been measured by means of a LYSO scintillator. Secondary protons have been identified exploiting the energy and time of flight in...

  16. Evaluation of plastic materials for range shifting, range compensation, and solid-phantom dosimetry for carbon-ion beams

    CERN Document Server

    Kanematsu, Nobuyuki; Ogata, Risa

    2012-01-01

    Purpose: Beam range control is the essence of radiotherapy with heavy charged particles. In conventional broad-beam delivery, fine range adjustment is achieved by insertion of range shifting and compensating materials. Ideally, such material should be water equivalent as well as that for dosimetry. In this study, we evaluated dosimetric water equivalency of four common plastics, HDPE, PMMA, PET, and POM, by uniformity of effective densities for carbon-ion-beam interactions. Methods: Using the Bethe formula for stopping, the Gottschalk formula for multiple scattering, and the Sihver formula for nuclear interactions, we calculated the effective densities of the plastics for these interactions. We tested HDPE, PMMA, and POM in carbon-ion-beam experiment and measured attenuations of carbon ions, which were compared with empirical linear-attenuation-model calculations. Results: The theoretical calculations resulted in reduced multiple scattering and increased nuclear interactions for HDPE compared to water, which ...

  17. Modeling of plasma heating with neutral beam injection in T-11 machine

    International Nuclear Information System (INIS)

    Computations of energy balance are presented for a tokamak with hot atom beam injection. Atom ionization, trapping of generated ions and energy transfer to plasma are examined. Energy loss in charge exchange is considered. Relationships are presented between the temperature and the injection power, the plasma density and other parameters. Possibilities are discussed for obtaining a collisionless ion regime

  18. Non-invasive monitoring of therapeutic carbon ion beams in a homogeneous phantom by tracking of secondary ions.

    Science.gov (United States)

    Gwosch, K; Hartmann, B; Jakubek, J; Granja, C; Soukup, P; Jäkel, O; Martišíková, M

    2013-06-01

    Radiotherapy with narrow scanned carbon ion beams enables a highly accurate treatment of tumours while sparing the surrounding healthy tissue. Changes in the patient's geometry can alter the actual ion range in tissue and result in unfavourable changes in the dose distribution. Consequently, it is desired to verify the actual beam delivery within the patient. Real-time and non-invasive measurement methods are preferable. Currently, the only technically feasible method to monitor the delivered dose distribution within the patient is based on tissue activation measurements by means of positron emission tomography (PET). An alternative monitoring method based on tracking of prompt secondary ions leaving a patient irradiated with carbon ion beams has been previously suggested. It is expected to help in overcoming the limitations of the PET-based technique like physiological washout of the beam induced activity, low signal and to allow for real-time measurements. In this paper, measurements of secondary charged particle tracks around a head-sized homogeneous PMMA phantom irradiated with pencil-like carbon ion beams are presented. The investigated energies and beam widths are within the therapeutically used range. The aim of the study is to deduce properties of the primary beam from the distribution of the secondary charged particles. Experiments were performed at the Heidelberg Ion Beam Therapy Center, Germany. The directions of secondary charged particles emerging from the PMMA phantom were measured using an arrangement of two parallel pixelated silicon detectors (Timepix). The distribution of the registered particle tracks was analysed to deduce its dependence on clinically important beam parameters: beam range, width and position. Distinct dependencies of the secondary particle tracks on the properties of the primary carbon ion beam were observed. In the particular experimental set-up used, beam range differences of 1.3 mm were detectable. In addition, variations in

  19. Laser transformation hardening on rod-shaped carbon steel byGaussian beam

    Institute of Scientific and Technical Information of China (English)

    Jong-Do KIM; Myeong-Hoon LEE; Su-Jin LEE; Woon-Ju KANG

    2009-01-01

    Laser transformation hardening(LTH) is one of the laser surface modification processes. The surface hardening of rod-shaped carbon steel (SM45C) was performed by lathe-based laser composite processor with Gaussian-beam optical head. The LTH characteristics by dominant processes, longitudinal and depth directional hardness distributions and behaviors of phase transformation in hardened zones were examined. Especially, two concepts of circumferential speed and theoretical overlap rate were applied. When laser power increased or circumferential speed decreased, the surface hardening depth gradually increases due to the increased heat input. Moreover, the longitudinal hardness distribution particularly shows periodicity of repetitive increase and decrease, which results from tempering effect by overlap. Finally, the feasibility of laser transformation hardening is verified by using the beam with Gaussian intensity distribution.

  20. Carbon doping of GaN with CBr4 in radio-frequency plasma-assisted molecular beam epitaxy

    OpenAIRE

    Green, D S; Mishra, U. K.; Speck, J.S.

    2004-01-01

    Carbon tetrabromide (CBr4) was studied as an intentional dopant during rf plasma molecular beam epitaxy of GaN. Secondary ion mass spectroscopy was used to quantify incorporation behavior. Carbon was found to readily incorporate under Ga-rich and N-rich growth conditions with no detectable bromine incorporation. The carbon incorporation [C] was found to be linearly related to the incident CBr4 flux. Reflection high-energy electron diffraction, atomic force microscopy and x-ray diffraction wer...

  1. Relative biological effects of carbon ion beams on mouse intestinal crypts

    Energy Technology Data Exchange (ETDEWEB)

    Basaki, Kiyoshi; Abe, Yoshinao [Hirosaki Univ., Aomori (Japan). School of Medicine; Tatsuzaki, Hideo; Akaizawa, Takashi; Ando, Soichiro; Ando, Koichi

    1998-03-01

    The relative biological effect (RBE) of carbon ion beams on mouse intestinal crypt cells were studied. Survival fractions of apoptotic sensitive cells, mitotic delay and colony assay were used for endpoints. Female C3H mice were total body irradiated using a carbon ion beam (290 MeV/u, 6 cm SOBP) at the National Institute of Radiological Science. For counting apoptosis and mitosis, the animals were irradiated either at LET of 70 keV/mm or 40 keV/mm. Fifteen minutes after irradiation, the mice received vincristine sulfate (0.8 mg/kg) and were sacrificed 2 hours and 45 minutes later. For colony assay, the animals were irradiated at an LET of 70 keV/mm and were sacrificed 3.5 days later. Jejunum were excised, fixed and cut into slices. The slides were stained with Hematoxylin and Eosin. Apoptosis-pyknotic cell- and mitosis were counted and survival fractions of apoptotic sensitive cells and mitotic delay time were obtained. The number of colonies were counted and survival fractions per circumference were obtained. Using these endpoints, RBEs were obtained. For survival fractions of apoptotic sensitive cells, no LET difference was observed and RBE was 1.7. For mitotic delay time, RBE was 2.3 and 1.7 at an LET of 70 keV/mm and 40 keV/mm, respectively. For colony assay, the RBE was 2.0-2.1. The different RBEs from three endpoints of the jejunal crypt may reflect each nature of the radiosensitivity to the carbon ion beam. In summary that mitotic delay time exhibited the same RBE as colony assay and RBE regarding apoptosis was less than those RBEs. (author)

  2. Study of the time and space distribution of {beta}{sup +} emitters from 80MeV/u carbon ion beam irradiation on PMMA

    Energy Technology Data Exchange (ETDEWEB)

    Agodi, C. [Laboratori Nazionali del Sud dell' INFN, Catania (Italy); Bellini, F. [Dipartimento di Fisica, Sapienza Universita di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Cirrone, G.A.P. [Laboratori Nazionali del Sud dell' INFN, Catania (Italy); Collamati, F. [Dipartimento di Fisica, Sapienza Universita di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Cuttone, G. [Laboratori Nazionali del Sud dell' INFN, Catania (Italy); De Lucia, E. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); De Napoli, M. [Laboratori Nazionali del Sud dell' INFN, Catania (Italy); Di Domenico, A.; Faccini, R.; Ferroni, F. [Dipartimento di Fisica, Sapienza Universita di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Fiore, S. [Dipartimento di Fisica, Sapienza Universita di Roma, Roma (Italy); Gauzzi, P. [Dipartimento di Fisica, Sapienza Universita di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Iarocci, E. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Dipartimento di Scienze di Base e Applicate per l' Ingegneria, Sapienza Universita di Roma, Roma (Italy); Marafini, M., E-mail: michela.marafini@roma1.infn.it [Museo Storico della Fisica e Centro Studi e Ricerche ' E. Fermi' , Roma (Italy); Mattei, I. [Dipartimento di Fisica, Roma Tre Universita di Roma, Roma (Italy); Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Paoloni, A. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); and others

    2012-07-15

    Proton and carbon ion therapy is an emerging technique used for the treatment of solid cancers. The monitoring of the dose delivered during such treatments and the on-line knowledge of the Bragg peak position is still a matter of research. A possible technique exploits the collinear 511keV photons produced by positrons annihilation from {beta}{sup +} emitters created by the beam. This paper reports rate measurements of the 511keV photons emitted after the interactions of a 80MeV/u fully stripped carbon ion beam at the Laboratori Nazionali del Sud (LNS) of INFN, with a poly-methyl methacrylate target. The time evolution of the {beta}{sup +} rate was parametrized and the dominance of {sup 11}C emitters over the other species ({sup 13}N, {sup 15}O, {sup 14}O) was observed, measuring the fraction of carbon ions activating {beta}{sup +} emitters to be (10.3{+-}0.7) Multiplication-Sign 10{sup -3}. The average depth in the PMMA of the positron annihilation from {beta}{sup +} emitters was also measured, D{sub {beta}{sup +}}=5.3{+-}1.1mm, to be compared to the expected Bragg peak depth D{sub Bragg}=11.0{+-}0.5mm obtained from simulations.

  3. In silico carbon molecular beam epitaxial growth of graphene on the h-BN substrate: carbon source effect on van der Waals epitaxy

    Science.gov (United States)

    Lee, Jonghoon; Varshney, Vikas; Park, Jeongho; Farmer, Barry L.; Roy, Ajit K.

    2016-05-01

    Against the presumption that hexagonal boron-nitride (h-BN) should provide an ideal substrate for van der Waals (vdW) epitaxy to grow high quality graphene films, carbon molecular beam epitaxy (CMBE) techniques using solid carbon sublimation have reported relatively poor quality of the graphene. In this article, the CMBE growth of graphene on the h-BN substrate is numerically studied in order to identify the effect of the carbon source on the quality of the graphene film. The carbon molecular beam generated by the sublimation of solid carbon source materials such as graphite and glassy carbon is mostly composed of atomic carbon, carbon dimers and carbon trimers. Therefore, the graphene film growth becomes a complex process involving various deposition characteristics of a multitude of carbon entities. Based on the study of surface adsorption and film growth characteristics of these three major carbon entities comprising graphite vapour, we report that carbon trimers convey strong traits of vdW epitaxy prone to high quality graphene growth, while atomic carbon deposition is a surface-reaction limited process accompanied by strong chemisorption. The vdW epitaxial behaviour of carbon trimers is found to be substantial enough to nucleate and develop into graphene like planar films within a nanosecond of high flux growth simulation, while reactive atomic carbons tend to impair the structural integrity of the crystalline h-BN substrate upon deposition to form an amorphous interface between the substrate and the growing carbon film. The content of reactive atomic carbons in the molecular beam is suspected to be the primary cause of low quality graphene reported in the literature. A possible optimization of the molecular beam composition towards the synthesis of better quality graphene films is suggested.Against the presumption that hexagonal boron-nitride (h-BN) should provide an ideal substrate for van der Waals (vdW) epitaxy to grow high quality graphene films, carbon

  4. Experimental study on fire protection methods of reinforced concrete beams strengthened with carbon fiber reinforced polymer

    Institute of Scientific and Technical Information of China (English)

    HU Kexu; HE Guisheng; LU Fan

    2007-01-01

    In this paper,two reinforced concrete (RC) beams strengthened with carbon fiber reinforced polymer (CFRP)and attached with thick-painted fire resistant coating were tested for fire resistance following the standard fire testing procedures.The experimental results show that the specimen pasted with the insulated layer of 50 mm in thickness could resist fire for 2.5 h.It is also demonstrated that the steel wire mesh embedded in the insulated layer can effectively prevent it from cracking and eroding under firing.

  5. Study on Regeneration of Powdered Activated Carbon by Electron Beam%电子束再生粉状活性炭的研究

    Institute of Scientific and Technical Information of China (English)

    吴明红; 包伯荣; 陈捷; 陆丽蓉

    2001-01-01

    The powdered activated carbon which had adsorbed phenylglycine solution from pharmaceutics factory can be regenerated by mean of irradiation of high-energy electron beams in oxygen, nitrogen and water vapor respectively. The effects of radiation dose and beam current on regeneration of activated carbon in different atmosphere were studied. Differential scanning calorimetry (DSC) and the iodine number of activated carbon were used to monitor the change of carbon adsorption. The results show that the powder activated carbon polluted with phenlglycine could be regenerated effectively by irradiation of high energy electron beams in nitrogen stream. The generation did not need high temperature, and the weight loss of carbon and energy consumption were minimum.

  6. 电子束再生粉状活性炭的研究%Study on Regeneration of Powdered Activated Carbon by Electron Beam

    Institute of Scientific and Technical Information of China (English)

    吴明红; 包伯荣; 陈捷; 陆丽蓉

    2000-01-01

    The powdered activated carbon which had adsorbed phenylglycine solution from pharmaceutics factory can be regenerated by mean of irradiation of high-energy electron beams in oxygen, nitrogen and water vapor respectively. The effects of radiation dose and beam current on regeneration of activated carbon in different atmosphere were studied. Differential scanning calorimetry (DSC) and the iodine number of activated carbon were used to monitor the change of carbon adsorption. The results show that the powder activated carbon polluted with phenlglycine could be regenerated effectively by irradiation of high energy electron beams in nitrogen stream. The generation did not need high temperature, and the weight loss of carbon and energy consumption were minimum.

  7. Treatment of industrial effluents using electron beam accelerator and adsorption with activated carbon. A comparative study

    International Nuclear Information System (INIS)

    Several methods are used In the pollutant removal from Industrial and domestic wastewater. However when the degradation of toxic organic pollutants, mainly the recalcitrant is objectified, the conventional treatments usually do not meet the desirable performance in the elimination or decrease the impact when the effluent are released to the environment what takes to the research of alternative methods that seek the improvement of the efficiency of the wastewater treatment systems jointly employees or separately. This work presents a study of degradation/removal of pollutants organic compounds comparing two methods using radiation from industrial electron beam and granular activated carbon (GAC). The removal efficiency of the pollutants was evaluated and it was verified that the efficiency of adsorption with activated carbon is similar to the radiation method. The obtained results allowed to evaluated the relative costs of these methods. (author)

  8. Measurement of inclusive charged current interactions on carbon in a few-GeV neutrino beam

    CERN Document Server

    jima, Y Naka; Brice, S J; Bugel, L; Catala-Perez, J; Cheng, G; Conrad, J M; Djurcic, Z; Dore, U; Finley, D A; Franke, A J; Giganti, C; Gomez-Cadenas, J J; Guzowski, P; Hanson, A; Hayato, Y; Hiraide, K; Jover-Manas, G; Karagiorgi, G; Katori, T; Kobayashi, Y K; Kobilarcik, T; Kubo, H; Kurimoto, Y; Louis, W C; Loverre, P F; Ludovici, L; Mahn, K B M; Mariani, C; Masuike, S; Matsuoka, K; McGary, V T; Metcalf, W; Mills, G B; Mitsuka, G; Miyachi, Y; Mizugashira, S; Moore, C D; Nakaya, T; Napora, R; Nienaber, P; Orme, D; Otani, M; Russell, A D; Sanchez, F; Shaevitz, M H; Shibata, T -A; Sorel, M; Stefanski, R J; Takei, H; Tanaka, H -K; Tanaka, M; Tayloe, R; Taylor, I J; Tesarek, R J; Uchida, Y; Van de Water, R; Walding, J J; Wascko, M O; White, H B; Yokoyama, M; Zeller, G P; Zimmerman, E D

    2010-01-01

    The SciBooNE Collaboration reports a measurement of inclusive charged current interactions of muon neutrinos on carbon with an average energy of 0.8~GeV using the Fermilab Booster Neutrino Beam. We compare our measurement with two neutrino interaction simulations: NEUT and NUANCE. The charged current interaction rates (product of flux and cross section) are extracted by fitting the muon kinematics, with a precision of 6-15% for the energy dependent and 3% for the energy integrated analyses. We also extract CC inclusive interaction cross sections from the observed rates, with a precision of 10-30% for the energy dependent and 8% for the energy integrated analyses. This is the first measurement of the CC inclusive cross section on carbon around 1 GeV. These results can be used to convert previous SciBooNE cross section ratio measurements to absolute cross section values.

  9. Transplantation of ES cells to Parkinson model rat irradiated with carbon ion beam

    International Nuclear Information System (INIS)

    The present study was designed to make a new Parkinson disease model using carbon ion beam. We irradiated right medial forebrain bundle of adult SD rats with charged carbon particles (290 MeV/nucleon, Mono peak, 150 Gy) and damaged right dopaminergic neurons pathway. To irradiate precisely, rats were set in the stereotactic frame with ear bars. Four weeks after the irradiation, behavioral test and in vitro autoradiography showed hemi-Parkinson model as well as 6-OHDA lesioned rats. Pathological examinations showed cell death, gliosis and inflammations at the irradiated area. However, no obvious alteration was observed at the surrounding normal tissue. These results indicated utility and validity of this method. (author)

  10. Range degradation and distal edge behavior of proton radiotherapy beams using 11C activation and Monte Carlo simulation

    Science.gov (United States)

    Elmekawy, Ahmed Farouk

    The distal edge of therapeutic proton radiation beams was investigated by different methods. Proton beams produced at the Hampton University Proton Therapy Institute (HUPTI) were used to irradiate a Polymethylmethacrylate (PMMA) phantom for three different ranges (13.5, 17.0 and 21.0 cm) to investigate the distal slope dependence of the Bragg peak. The activation of 11 C was studied by scanning the phantom less than 10 minutes post-irradiation with a Philips Big Bore Gemini(c) PET/CT. The DICOM images were imported into the Varian Eclipse(c) Treatment Planning System (TPS) for analysis and then analyzed by ImageJ(c) . The distal slope ranged from ?0.1671 +/- 0.0036 to -0.1986 +/- 0.0052 (pixel intensity/slice number) for ranges 13.5 to 21.0 cm respectively. A realistic description of the setup was modeled using the GATE 7.0 Monte Carlo simulation tool and compared to the experiment data. The results show the distal slope ranged from -0.1158+/-0.0133 to -0.0787+/-0.002 (Gy/mm). Additionally, low activity, 11C were simulated to study the 11C reconstructed half-life dependence versus the initial activity for six ranges chosen around the previous activation study. The results of the expected/nominal half-life vs. activity ranged from -5 x 10-4 +/- 2.8104 x 10-4 to 1.6 x 10-3 +/- 9.44 x 10-4 (%diff./Bq). The comparison between two experiments with proton beams on a PMMA phantom and multi-layer ion chamber, and two GATE simulations of a proton beam incident on a water phantom and 11C PET study show that: (i) the distal fall-off variation of the steepness of the slopes are found to be similar thus validating the sensitivity of the PET technique to the range degradation and (ii) the average of the super-ratios difference between all studies observed is primarily due to the difference in the dose deposited in the media.

  11. Experience with carbon-11 choline positron emission tomography in prostate carcinoma

    International Nuclear Information System (INIS)

    We investigated the potential of carbon-11 choline positron emission tomography (PET) for the detection of lymph node and bone metastases in prostate cancer. A total of 23 patients were studied (known metastases: 8; suspicion of metastases: 3; primary staging: 12). Whole-body PET imaging was performed 5 min after injection of the tracer and completed within 1 h. Focally increased tracer uptake in bone or abdominal lymph node regions was interpreted as representing tumour involvement. All known bone and lymph node metastases could be recognized by [11C]choline PET. One out of ten negative scans for primary staging was false-negative (lymph node 11C]choline PET is a promising new tool for the primary staging of prostate cancer, with lymph node and bone metastases demonstrating high tracer uptake. Therapeutic management could be influenced by these results in that the technique may permit avoidance of surgical lymph node exploration. (orig.)

  12. The CBS-The Most Cost Effective and High Performance Carbon Beam Source Dedicated for a New Generation Cancer Therapy

    CERN Document Server

    Kumada, Masayuki; Leivichev, E B; Parkhomchuk, Vasily; Podgorny, Fedor; Rastigeev, Sergey; Reva, Vladimir B; Skrinsky, Aleksander Nikolayevich; Vostrikov, Vladimir

    2005-01-01

    A Carbon ion beam is a superior tool to x-rays or a proton beam in both physical and biological doses in treating a cancer. A Carbon beam has an advantage in treating radiation resistant and deep-seated tumors. Its radiological effect is of a mitotic independent nature. These features improve hypofractionation, typically reducing the number of irradiations per patient from 35 to a few. It has been shown that a superior QOL(Quality Of Life) therapy is possible by a carbon beam.The only drawback is its high cost. Nevertheless, tens of Prefectures and organizations are eagerly considering the possibility of having a carbon ion therapy facility in Japan. Germany, Austria, Italy, China, Taiwan and Korea also desire to have one.A carbon beam accelerator of moderate cost is about 100 Million USD. With the "CBS" design philosophy, which will be described in this paper, the cost could be factor of 2 or 3 less, while improving its performance more than standard designs. Novel extraction techniques, a new approach to a ...

  13. Localized surface grafting reactions on carbon nanofibers induced by gamma and e-beam irradiation

    Science.gov (United States)

    Evora, M. C.; Araujo, J. R.; Ferreira, E. H. M.; Strohmeier, B. R.; Silva, L. G. A.; Achete, C. A.

    2015-04-01

    Electron beam and gamma-ray irradiation have potential application to modify the carbon fiber nanostructures in order to produce useful defects in the graphitic structure and create reactive sites. In this study, the methodology to functionalize carbon nanofiber (CNF), via a radiation process and using acrylic acid as a source of oxygen functional groups, was investigated. The samples were submitted to a direct grafting radiation process with electron beam and gamma-ray source. Several parameters were changed such as: acrylic acid concentration, radiation dose and percentage of inhibitor necessary to achieve functionalization, with higher percentage of oxygen functional groups on CNF surface, and better dispersion. The better results achieved were when mixing CNF in a solution of acrylic acid with 6% of inhibitor (FeSO4·7H2O) and irradiated at 100 kGy. The samples were characterized by X-ray photoelectron spectroscopy and the surface composition (atomic%) showed a significant increase of oxygen content for the samples after irradiation. Also, the dispersion of the functionalized CNF in water was stable during months which may be a good indication that the functionalization process of CNF via ionizing radiation was successful.

  14. Effects of carbon ion beam irradiation on the shoot regeneration from in vitro axillary bud explants of the Impatiens hawkeri

    Science.gov (United States)

    Zhou, Libin; Zhou, Libin; Li, Wenjian; Li, Ping; Dong, Xicun; Qu, Ying; Ma, Shuang; Li, Qiang

    Accelerated ion beams is an excellent mutagen in plant breeding which can induce higher mutation frequencies and wider mutation spectrum than those of low linear energy transfer (LET) irradiations, such as X-rays (Okamura et al. 2003, Yamaguchi et al. 2003). Mutation breeding operation of two Saintpaulia ionahta cultivars using the method combining plant tissue culture technique and carbon ion beam irradiations were set out at Institute of Modern Physics from 2005 (Zhou et al. 2006). The effects of 960 MeV carbon ion beam and 8 MeV X-ray irradiations on regenerated shoots of Impatiens hawkeri from another kind of explants named in vitro axillary buds explants were studied recently. The biology endpoints in this study included relative number of roots (RNR), relative length of roots (RLR), relative height of shoots (RHS), relative number of nodes (RNN), survival fraction (SF) and morphology changes in the regenerated shoots. The experimental results showed that carbon ion beams inhibited the root and stem developments of axillary bud explants more severely than X-rays did. And the 50% lethal dose (LD50 ) is about 23.3 Gy for the carbon ion beam and 49.1 Gy for the X-rays, respectively. Relative biological effectiveness (RBE) of Impatiens hawkeri with respect to X-rays according to 50% SF was about two. Secondly, the percentage of shoots regenerated with malformed shoots including curliness, carnification, nicks in all Impatiens hawkeri axillary bud explants irradiated with carbon ion beam at 20 Gy accounted for 55.6%, while the highest number for the 40 Gy X-ray irradiation was 40%. Last, many regenerated shoots whose vascular bundle fused together were obtained only from explants irradiated with carbon ion beams. Based on the results above, it can be concluded that the effect of mutation induction by carbon ion beam irradiation on the axillary explants of Impatiens hawkeri is better than that by X-ray irradiation; and the optimal mutagenic dose varies from 20 Gy

  15. Flexural rigidity evolvement laws of reinforced concrete beams strengthened with carbon fiber laminates

    Institute of Scientific and Technical Information of China (English)

    NIU Peng-zhi; HUANG Pei-yan; DENG Jun; HAN Qiang

    2007-01-01

    Extensive research has shown that externally bonded carbon fiber reinforced polymer (CFRP) laminates are particularly suitable for improving the fatigue behavior of reinforced concrete (RC) beams. This paper presents the research on flexural rigidity evolvement laws by testing 14 simple-supported RC beams strengthened with carbon fiber laminates (CFL) under cyclic load, and 2 under monotone load as a reference. The cyclic load tests revealed the peak load applied onto the surface of a supported RC beam strengthened with CFL is linear to the logarithm of its fatigue life, and the flexural rigidity evolvement undergoes three distinct phases: a rapid decrease from the start to about 5% of the fatigue life; an even development from 5% to about 99% of the fatigue life; and a succedent rapid decrease to failure. When the ratio of fatigue cycles to the fatigue life is within 0.05 to 0.99, the flexural rigidity varies linearly with the ratio. The peak load does not affect the flexural rigidity evolvement if it is not high enough to make the main reinforcements yield. The dependences of the flexural rigidity of specimens formed in the same group upon their fatigue cycles normalized by fatigue life are almost coincident. This implies the flexural rigidity may be a material parameter independent of the stress level. These relationships of flexural rigidity to fatigue cycles, and fatigue life may be able to provide some hints for fatigue design and fatigue life evaluation of RC member strengthened with CFL; nevertheless the findings still need verifying by more experiments.

  16. Comparing models of the periodic variations in spin-down and beam-width for PSR B1828-11

    CERN Document Server

    Ashton, G; Prix, R

    2015-01-01

    We build a framework using tools from Bayesian data analysis to evaluate models explaining the periodic variations in spin-down and beam-width of PSR B1828-11. The available data consists of the time averaged spin-down rate, which displays a distinctive double-peaked modulation, and measurements of the beam-width. Two concepts exist in the literature that are capable of explaining these variations; we will formulate predictive models from these and quantitatively compare them. The first concept is phenomenological and stipulates that the magnetosphere undergoes periodic switching between two meta-stable states as first suggested by Lyne et al. (2010). The second concept, precession, was first considered as a candidate for the modulation of B1828-11 by Stairs et al. (2000). We quantitatively compare models built from these concepts using a Bayesian odds-ratio. Because the phenomenological switching model itself was informed by this data in the first place, it is difficult to specify appropriate parameter- spac...

  17. Synthesis of carbon-11 labeled dexetimide and levetimide for studying muscarinic acetylcholine receptors

    International Nuclear Information System (INIS)

    The localization and quantitation of the muscarinic acetylcholine receptor (m-AChR) in the living human brain using a non-invasive method, such as positron emission tomography (PET), may provide valuable information about receptor changes which have been observed post mortem in patients with Huntington's chorea and Alzheimer's dementia, as well as normal brain mechanisms mediated by the m-AChR. Although quinuclidinyl benzilate has been radioiodinated and radiomethylatd, the former is not useful with PET and the latter does not penetrate the blood-brain barrier; therefore, the authors chose to radiolabel dexetimide, a ligand which labels m-AChR in vitro and in vivo, and levetimide, its inactive enantiomer. Carbon-11 labeled carbon dioxide is bubbled through a tetrahydrofuran (THF) solution of phenylmagnesium chloride (1 M, l ml) after which 2 mg of lithium aluminium hydride is added in THF (500 μl). After evaporation of the solvent, 48% hydriodic acid (l ml) is added and the solution is heated for 1 minute. Carbon-11 labeled benzyl iodide is extracted into methylene chloride, added to a solution of nor-benzyl dexetimide or levetimide, and heated for several minutes. Purification is accomplished using semi-preparative reverse phase high performance liquid chromatography (HPLC). Analytical HPLC is used to determine the radiochemical purity and specific activity

  18. Synthesis of carbon-11 labeled dexetimide and levetimide for studying muscarinic acetylcholine receptors

    Energy Technology Data Exchange (ETDEWEB)

    Dannals, R.F.; Langstrom, B.; Ravert, H.T.; Wilson, A.A.; Wagner, H.N. Jr.

    1985-05-01

    The localization and quantitation of the muscarinic acetylcholine receptor (m-AChR) in the living human brain using a non-invasive method, such as positron emission tomography (PET), may provide valuable information about receptor changes which have been observed post mortem in patients with Huntington's chorea and Alzheimer's dementia, as well as normal brain mechanisms mediated by the m-AChR. Although quinuclidinyl benzilate has been radioiodinated and radiomethylatd, the former is not useful with PET and the latter does not penetrate the blood-brain barrier; therefore, the authors chose to radiolabel dexetimide, a ligand which labels m-AChR in vitro and in vivo, and levetimide, its inactive enantiomer. Carbon-11 labeled carbon dioxide is bubbled through a tetrahydrofuran (THF) solution of phenylmagnesium chloride (1 M, l ml) after which 2 mg of lithium aluminium hydride is added in THF (500 ..mu..l). After evaporation of the solvent, 48% hydriodic acid (l ml) is added and the solution is heated for 1 minute. Carbon-11 labeled benzyl iodide is extracted into methylene chloride, added to a solution of nor-benzyl dexetimide or levetimide, and heated for several minutes. Purification is accomplished using semi-preparative reverse phase high performance liquid chromatography (HPLC). Analytical HPLC is used to determine the radiochemical purity and specific activity.

  19. Charge exchange recombination spectroscopy measurements in the extreme ultraviolet region of central carbon concentrations during high power neutral beam heating in TFTR [Tokamak Fusion Test Reactor

    International Nuclear Information System (INIS)

    The carbon concentration in the central region of TFTR discharges with high power neutral beam heating has been measured by charge-extracted recombination spectroscopy (CXRS) of the C+5 n = 3--4 transition in the extreme ultraviolet region. The carbon concentrations were deduced from absolute measurements of the line brightness using a calculation of the beam attenuation and the appropriate cascade-corrected line excitation rates. As a result of the high ion temperatures in most of the discharges, the contribution of beam halo neutrals to the line brightness was significant and therefore had to be included in the modeling of the data. Carbon concentrations have been measured in discharges with Ip = 1.0-1.6 MA and beam power in the range of 2.6-30 MW, including a number of supershots. The results are in good agreement with carbon concentrations deduced from the visible bremsstrahlung Zeff and metallic impurity concentrations measured by x-ray pulse-height analysis, demonstrating the reliability of the atomic rates used in the beam attenuation and line excitation calculations. Carbon is the dominant impurity species in these discharges; the oxygen concentration measured via CXRS in a high beam power case was 0.0006 of ne, compard to 0.04 for carbon. Trends with Ip and beam power in the carbon concentration and the inferred deuteron concentration are presented. The carbon concentration is independent of Ip and decreases from 0.13 at 2.6 MW beam power to 0.04 at 30 MW, while the deuteron concentration increases from 0.25 to 0.75 over the same range of beam power. These changes are primarily the result of beam particle fueling, as the carbon density did not vary significantly with beam power. The time evolutions of the carbon and deuteron concentrations during two high power beam pulses, one which exhibited a carbon bloom and one which did not, are compared. 30 refs., 12 figs., 2 tabs

  20. Analytic expressions for the inelastic scattering and energy loss of electron and proton beams in carbon nanotubes

    International Nuclear Information System (INIS)

    We have determined ''effective'' Bethe coefficients and the mean excitation energy of stopping theory (I-value) for multiwalled carbon nanotubes (MWCNTs) and single-walled carbon nanotube (SWCNT) bundles based on a sum-rule constrained optical-data model energy loss function with improved asymptotic properties. Noticeable differences between MWCNTs, SWCNT bundles, and the three allotropes of carbon (diamond, graphite, glassy carbon) are found. By means of Bethe's asymptotic approximation, the inelastic scattering cross section, the electronic stopping power, and the average energy transfer to target electrons in a single inelastic collision, are calculated analytically for a broad range of electron and proton beam energies using realistic excitation parameters.

  1. Analytic expressions for the inelastic scattering and energy loss of electron and proton beams in carbon nanotubes

    Science.gov (United States)

    Emfietzoglou, D.; Kyriakou, I.; Garcia-Molina, R.; Abril, I.; Kostarelos, K.

    2010-09-01

    We have determined "effective" Bethe coefficients and the mean excitation energy of stopping theory (I-value) for multiwalled carbon nanotubes (MWCNTs) and single-walled carbon nanotube (SWCNT) bundles based on a sum-rule constrained optical-data model energy loss function with improved asymptotic properties. Noticeable differences between MWCNTs, SWCNT bundles, and the three allotropes of carbon (diamond, graphite, glassy carbon) are found. By means of Bethe's asymptotic approximation, the inelastic scattering cross section, the electronic stopping power, and the average energy transfer to target electrons in a single inelastic collision, are calculated analytically for a broad range of electron and proton beam energies using realistic excitation parameters.

  2. Radiation biophysical studies with mammalian cells and a modulated carbon ion beam

    International Nuclear Information System (INIS)

    Chinese hamster (V-79) and human kidney (T-1) cells were irradiated in stirred suspensions placed at various positions in the plateau and extended Bragg peak of a 400-MeV/amu carbon ion beam. The range of the ions was modulated by a lead (translational) ridge filter and a brass (spiral) ridge filter designed to produce extended peaks of approximately 4 and 10 cm, respectively. Stationary-phase and G1-phase populations of Chinese hamster cells were found to have different absolute radiosensitivities which, in turn, were different from that of asynchronous human kidney cells. The increase in relative biological effectiveness (RBE) observed as carbon ions were slowed down and stopped in water was similar for the three cell populations at doses greater than 400 rad. At lower doses the RBE was greater for the hamster cell populations than for the human kidney cells. The gain in RBE (at the 50% survival level) between the plateaus and the middle region of the extended peaks was approximately 2.0 and 1.7 for the 4- and 10-cm extended peaks, respectively. Oxygen enhancement ratios (OER) were determined at the 10% survival levels with stationary-phase populations of hamster cells. Values of 2.8, 2.65, and 1.65 were obtained for the OER of 220-kV x rays, plateau carbon, and the middle region of the 4-cm carbon peak, respectively. Across the 10-cm carbon peak the OER was found to vary between values of 2.4 to 1.55 from the proximal to distal positions

  3. Carbon-ion beam irradiation kills X-ray-resistant p53-null cancer cells by inducing mitotic catastrophe.

    Directory of Open Access Journals (Sweden)

    Napapat Amornwichet

    Full Text Available BACKGROUND AND PURPOSE: To understand the mechanisms involved in the strong killing effect of carbon-ion beam irradiation on cancer cells with TP53 tumor suppressor gene deficiencies. MATERIALS AND METHODS: DNA damage responses after carbon-ion beam or X-ray irradiation in isogenic HCT116 colorectal cancer cell lines with and without TP53 (p53+/+ and p53-/-, respectively were analyzed as follows: cell survival by clonogenic assay, cell death modes by morphologic observation of DAPI-stained nuclei, DNA double-strand breaks (DSBs by immunostaining of phosphorylated H2AX (γH2AX, and cell cycle by flow cytometry and immunostaining of Ser10-phosphorylated histone H3. RESULTS: The p53-/- cells were more resistant than the p53+/+ cells to X-ray irradiation, while the sensitivities of the p53+/+ and p53-/- cells to carbon-ion beam irradiation were comparable. X-ray and carbon-ion beam irradiations predominantly induced apoptosis of the p53+/+ cells but not the p53-/- cells. In the p53-/- cells, carbon-ion beam irradiation, but not X-ray irradiation, markedly induced mitotic catastrophe that was associated with premature mitotic entry with harboring long-retained DSBs at 24 h post-irradiation. CONCLUSIONS: Efficient induction of mitotic catastrophe in apoptosis-resistant p53-deficient cells implies a strong cancer cell-killing effect of carbon-ion beam irradiation that is independent of the p53 status, suggesting its biological advantage over X-ray treatment.

  4. Reduced myocardial carbon-11 hydroxyephedrine retention is associated with poor prognosis in chronic heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Pietilae, M.; Ukkonen, H. [Dept. of Medicine, Turku University Central Hospital (Finland); Turku PET Centre, Turku (Finland); Malminiemi, K. [Dept. of Clinical Chemistry, Tampere University Hospital (Finland); Saraste, M. [Dept. of Clinical Physiology, Turku University Central Hospital (Finland); Naagren, K.; Lehikoinen, P. [Turku PET Centre, Turku (Finland); Voipio-Pulkki, L.-M. [Dept. of Medicine, Turku University Central Hospital (Finland); Dept. of Medicine, Helsinki University Central Hospital (Finland)

    2001-03-01

    Abnormalities of the autonomic nervous system are known to be of prognostic significance in chronic heart failure (CHF). The prognostic value of positron emission tomography (PET) imaging of cardiac autonomic innervation in CHF has not been explored previously. We retrospectively studied the survival data of 46 NYHA class II-III CHF patients (mean LVEF 35%{+-}8%) who had undergone carbon-11 hydroxyephedrine ({sup 11}C-HED) studies at the Turku PET Centre between August 1992 and March 1996. The origin of CHF was dilated cardiomyopathy in 13 of the 46 patients and coronary artery disease with at least one prior myocardial infarction in the remaining 33. Data on causes of death and heart transplantation were collected, and the statistically significant predictors of prognosis were analysed using Cox's proportional hazards regression. During the mean follow-up period of 55{+-}19 months, 11 deaths occurred and two patients underwent heart transplantation successfully. Eleven end-points were classified as cardiac (nine sudden cardiac deaths and two deaths due to progressive heart failure) and two as non-cardiac. When divided into two groups based on the median of {sup 11}C-HED retention (mean 0.184{+-}0.061, median 0.183), eight end-points (death or cardiac transplantation) were reached in the group with {sup 11}C-HED retention below the median and three in the group with {sup 11}C-HED retention above the median (P<0.02). In proportional hazards regression analysis, only peak oxygen uptake (peak VO{sub 2}), left ventricular end-diastolic volume and HED retention were found to be statistically significant. It is concluded that {sup 11}C-HED PET provides independent prognostic information in patients with CHF. (orig.)

  5. Emulsion Cloud Chamber technique to measure the fragmentation of a high-energy carbon beam

    CERN Document Server

    De Lellis, G; Buontempo, S; Capua, F D; Furusawa, Y; Lavina, L S; Marotta, A; Migliozzi, P; Naganawa, N; Petukhov, Yu P; Pistillo, C; Russo, A; Strolin, P; Tioukov, V; Toshito, T; Yasuda, N

    2007-01-01

    Beams of Carbon nuclei are now in use or planned to be used in various centers for cancer treatment around the world. The knowledge of the fragmentation of Carbon nuclei when they interact with the human body is important for evaluating of the spatial profile of their energy deposition in the tissues, hence the damage to tissues neighbouring the tumor. To this purpose, the identification of the fragmentation products is a key element. We present in this paper the charge measurement of about 3000 fragments produced by the interaction of $^{12}$C nuclei with an energy of 400 MeV/nucleon in a detector simulating the density of the human body. The nuclear emulsion technique is used, by means of the so-called Emulsion Cloud Chamber. The nuclear emulsions are inspected using fast automated microscopes recently developed. A charge assignment efficiency of more than 99% is achieved. The separation of Hydrogen, Helium, Lithium, Berillium, Boron and Carbon can be achieved at two standard deviations or considerably more...

  6. Strain measurements on concrete beam and carbon fiber cable with distributed optical fiber Bragg grating sensors

    Science.gov (United States)

    Nellen, Philipp M.; Bronnimann, Rolf; Sennhauser, Urs J.; Askins, Charles G.; Putnam, Martin A.

    1996-09-01

    We report on civil engineering applications of wavelength multiplexed optical fiber Bragg grating arrays directly produced on the draw tower for testing and surveying advanced structures and materials such as carbon fiber reinforced concrete elements and prestressing cables. We equipped a 6 by 0.9 by 0.5 m concrete beam, which was reinforced with carbon fiber reinforced epoxy laminates, and a 7-m long prestressing carbon fiber cable made of seven twisted strands, with optical fiber Bragg grating sensors. Static strains up to 8000 micrometers/m and dynamic strains up to 1200 micrometers/m were measured with a Michelson interferometer used as Fourier spectrometer with a resolution of about 10 micrometers/m for all sensors. Comparative measurements with electrical resistance strain gauges were in good agreement with the fiber optical results. We installed the fiber sensors in two different arrangements: some Bragg grating array elements measured local strain while others were applied in an extensometric configuration to measure moderate strain over a base length of 0.1 to 1 m.

  7. Imaging the interphase of carbon fiber composites using transmission electron microscopy:Preparations by focused ion beam, ion beam etching, and ultramicrotomy

    Institute of Scientific and Technical Information of China (English)

    Wu Qing; Li Min; Gu Yizhuo; Wang Shaokai; Zhang Zuoguang

    2015-01-01

    Three sample preparation techniques, focused ion beam (FIB), ion beam (IB) etching, and ultramicrotomy (UM) were used in comparison to analyze the interphase of carbon fiber/epoxy composites using transmission electron microscopy. An intact interphase with a relatively uniform thickness was obtained by FIB, and detailed chemical analysis of the interphase was investigated by electron energy loss spectroscopy. It shows that the interphase region is 200 nm wide with an increasing oxygen-to-carbon ratio from 10% to 19% and an almost constant nitrogen-to-carbon ratio of about 3%. However, gallium implantation of FIB tends to hinder fine structure analysis of the interphase. For IB etching, the interphase region is observed with transition morphology from amorphous resin to nano-crystalline carbon fiber, but the uneven sample thickness brings difficulty for quantitative chemical analysis. Moreover, UM tends to cause damage and/or deformation on the interphase. These results are meaningful for in-depth understanding on the interphase characteristic of carbon fiber composites.

  8. Deflection analysis of reinforced concrete beams strengthened with carbon fibre reinforced polymer under long-term load action

    Institute of Scientific and Technical Information of China (English)

    Mykolas DAUGEVI(C)IUS; Juozas VALIVONIS; Gediminas MAR(C)IUKAITIS

    2012-01-01

    This paper presents the results of an experimental research on reinforced concrete beams strengthened with an external carbon fibre reinforced polymer (CFRP) layer under long-term load action that lasted for 330 d.We describe the characteristics of deflection development of the beams strengthened with different additional anchorages of the external carbon fibre composite layer during the period of interest.The conducted experiments showed that the additional anchorage influences the slip of the extemal layer with respect to the strengthened element.Thus,concrete and carbon fibre composite interface stiffness decreases with a long-term load action.Therefore,the proposed method of analysis based on the built-up-bars theory can be used to estimate concrete and carbon fibre composite interface stiffness in the case of long-term load.

  9. Study of the time and space distribution of $\\beta^+$ emitters from $80\\ \\mega\\electronvolt/$u carbon ion beam irradiation on PMMA

    CERN Document Server

    Agodi, C; Cirrone, G A P; Collamati, F; Cuttone, G; De Lucia, E; De Napoli, M; Di Domenico, A; Faccini, R; Ferroni, F; Fiore, S; Gauzzi, P; Iarocci, E; Marafini, M; Mattei, I; Paoloni, A; Patera, V; Piersanti, L; Romano, F; Sarti, A; Sciubba, A; Voena, C

    2012-01-01

    Proton and carbon ion therapy is an emerging technique used for the treatment of solid cancers. The monitoring of the dose delivered during such treatments and the on-line knowledge of the Bragg peak position is still a matter of research. A possible technique exploits the collinear $511\\ \\kilo\\electronvolt$ photons produced by positrons annihilation from $\\beta^+$ emitters created by the beam. This paper reports rate measurements of the $511\\ \\kilo\\electronvolt$ photons emitted after the interactions of a $80\\ \\mega\\electronvolt / u$ fully stripped carbon ion beam at the Laboratori Nazionali del Sud (LNS) of INFN, with a Poly-methyl methacrylate target. The time evolution of the $\\beta^+$ rate was parametrized and the dominance of $^{11}C$ emitters over the other species ($^{13}N$, $^{15}O$, $^{14}O$) was observed, measuring the fraction of carbon ions activating $\\beta^+$ emitters $A_0=(10.3\\pm0.7)\\cdot10^{-3}$. The average depth in the PMMA of the positron annihilation from $\\beta^+$ emitters was also meas...

  10. Plasma-assisted molecular beam epitaxy of (11-22)-oriented 3-nitrides

    International Nuclear Information System (INIS)

    This work reports on the molecular-beam epitaxial growth of (1122)-oriented semi-polar nitride semiconductors using m-sapphire substrates. The (1122) crystallographic orientation is predefined by AlN deposition on m-sapphire under N excess. On top of this AlN buffer layer, undoped or Si-doped two-dimensional GaN(1122) films are formed under Ga-rich conditions, with a stabilized Ga-excess ad-layer of about 1.05±0.10 ML. In contrast, Mg tends to segregate on the GaN surface, inhibiting the self-regulated Ga excess film. Nevertheless, uniform Mg incorporation can be obtained, and p-type conductivity was achieved. GaN/AlN quantum wells are synthesized by deposition of the binary compounds under the above-described conditions. In the case of GaN/AlN quantum dots, the three-dimensional transition is induced by a growth interruption under vacuum. The reduction of the internal electric field in GaN/AlN nano-structures is confirmed by the blue shift of the photoluminescence spectrum and by the short photoluminescence decay times measured at low temperature. These results are consistent with theoretical calculations of the electronic structure. (author)

  11. Electron-beam assisted selective growth of graphenic carbon thin films on SiO2/Si and quartz substrates

    OpenAIRE

    Knyazev, Maxim; Sedlovets, Daria; Trofimov, Oleg; Redkin, Arkady

    2015-01-01

    The first selective growth of graphenic carbon thin films on silicon dioxide is reported. A preliminary e-beam exposure of the substrate is found to strongly affect the process of such films growth. The emphasis is placed on the influence of substrate exposure on the rate of carbon deposition. The explanation of this effect is proposed. The data of electrical and optical measurements and the results of atomic force and scanning electron microscopy and Raman spectroscopy studies are reported. ...

  12. Irradiation of 135 MeV/u carbon and neon beams for studies of radiation biology

    International Nuclear Information System (INIS)

    A heavy ion irradiation system was designed and constructed at RIKEN ring cyclotron facility for studies of radiation physics and radiation biology. Carbon and neon beams of 135 MeV/u were firstly used for the experiments. A pair of wobbler magnets and a scatterer were used for obtaining the uniform radiation field of about 10 cm in diameter. A parallel plate ionization chamber was used for dose monitoring. A range shifter was used for degrading the initial energy of the heavy ions. Precise depth dose distributions were measured by a small parallel plate ionization chamber and a variable length water column. LET (linear energy transfer) of the heavy ion radiation fields were measured by a parallel plate proportional chamber. From these basic measurements, biological experiments using these heavy ions are now carried out at this facility. (author)

  13. Cell survival in carbon beams - comparison of amorphous track model predictions

    DEFF Research Database (Denmark)

    Grzanka, L.; Greilich, S.; Korcyl, M.;

    Introduction: Predictions of the radiobiological effectiveness (RBE) play an essential role in treatment planning with heavy charged particles. Amorphous track models ( [1] , [2] , also referred to as track structure models) provide currently the most suitable description of cell survival under ion...... distribution models, and gamma response models was developed. This software can be used for direct numerical comparison between the models, submodels and their parameters and experimental data. In the present paper, we look at 10%-survival data from cell lines irradiated in vitro with carbon and proton beams...... irradiation. The aim of this paper is to compare the predictions from different amorphous approaches found in the literature - more specifically the phenomenological, analytical model by Katz and co-workers [1] and a Monte-Carlo based full as implemented for example in the local effect model by Scholz et al...

  14. Pairing Correlations in Odd-Mass Carbon Isotopes and in 11Be

    CERN Document Server

    Samana, A R; Krmpotic, F; Tarutina, T

    2005-01-01

    In this paper we present an exploratory study of structure of the odd-mass carbon isotopes 15C, 17C and 19C, using the BCS and the projected BCS (PBCS) models to assess the importance of pairing correlations in these light nuclei. Further, we consider the structure of 13C and 11Be using the quasiparticle-rotor model to better understand the origin of spin and parity of the levels and the degree of deformation of the corresponding cores. The quasiparticle-vibrator model is also employed as an alternative model. Comparison of our results with several recent papers on the same subject is also presented. We have shown that the inclusion of the pairing interaction and of the concomitant Pauli principle is imperative for a realistic description of heavy odd-mass carbon isotopes and in the core-coupling models for 13C and 11Be. The important role played by the particle number conservation in relatively light and/or exotic nuclei has been confirmed as well.

  15. SU-E-I-11: A New Cone-Beam CT System for Bedside Head Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sun, H; Zeng, W; Xu, P; Wang, Z; Xing, X; Sun, M [Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Jiangsu (China)

    2015-06-15

    Purpose: To design and develop a new mobile cone-beam CT (CBCT) system for head imaging with good soft-tissue visibility, to be used bedside in ICU and neurosurgery department to monitor treatment and operation outcome in brain patients. Methods: The imaging chain consists of a 30cmx25cm amorphous silicon flat panel detector and a pulsed, stationary anode monoblock x-ray source of 100kVp at a maximal tube current of 10mA. The detector and source are supported on motorized mechanisms to provide detector lateral shift and source angular tilt, enabling a centered digital radiographic imaging mode and half-fan CBCT, while maximizing the use of the x-ray field and keep the source to detector distance short. A focused linear anti-scatter grid is mounted on the detector, and commercial software with scatter and other corrective algorithms is used for data processing and image reconstruction. The gantry rotates around a horizontal axis, and is able to adjust its height for different patient table positions. Cables are routed through a custom protective sleeve over a large bore with an in-plane twister band, facilitating single 360-degree rotation without a slip-ring at a speed up to 5 seconds per rotation. A UPS provides about 10 minutes of operation off the battery when unplugged. The gantry is on locked casters, whose brake is control by two push handles on both sides for easy reposition. The entire system is designed to have a light weight and a compact size for excellent maneuverability. Results: System design is complete and main imaging components are tested. Initial results will be presented and discussed later in the presentation. Conclusion: A new mobile CBCT system for head imaging is being developed. With its compact size, a large bore, and quality design, it is expected to be a useful imaging tool for bedside uses. The work is supported by a grant from Chinese Academy of Sciences.

  16. SU-E-I-11: A New Cone-Beam CT System for Bedside Head Imaging

    International Nuclear Information System (INIS)

    Purpose: To design and develop a new mobile cone-beam CT (CBCT) system for head imaging with good soft-tissue visibility, to be used bedside in ICU and neurosurgery department to monitor treatment and operation outcome in brain patients. Methods: The imaging chain consists of a 30cmx25cm amorphous silicon flat panel detector and a pulsed, stationary anode monoblock x-ray source of 100kVp at a maximal tube current of 10mA. The detector and source are supported on motorized mechanisms to provide detector lateral shift and source angular tilt, enabling a centered digital radiographic imaging mode and half-fan CBCT, while maximizing the use of the x-ray field and keep the source to detector distance short. A focused linear anti-scatter grid is mounted on the detector, and commercial software with scatter and other corrective algorithms is used for data processing and image reconstruction. The gantry rotates around a horizontal axis, and is able to adjust its height for different patient table positions. Cables are routed through a custom protective sleeve over a large bore with an in-plane twister band, facilitating single 360-degree rotation without a slip-ring at a speed up to 5 seconds per rotation. A UPS provides about 10 minutes of operation off the battery when unplugged. The gantry is on locked casters, whose brake is control by two push handles on both sides for easy reposition. The entire system is designed to have a light weight and a compact size for excellent maneuverability. Results: System design is complete and main imaging components are tested. Initial results will be presented and discussed later in the presentation. Conclusion: A new mobile CBCT system for head imaging is being developed. With its compact size, a large bore, and quality design, it is expected to be a useful imaging tool for bedside uses. The work is supported by a grant from Chinese Academy of Sciences

  17. Analysis of the fine structure of Sn$^{11+...14+}$ ions by optical spectroscopy in an electron beam ion trap

    CERN Document Server

    Windberger, A; Borschevsky, A; Ryabtsev, A; Dobrodey, S; Bekker, H; Eliav, E; Kaldor, U; Ubachs, W; Hoekstra, R; López-Urrutia, J R Crespo; Versolato, O O

    2016-01-01

    We experimentally re-evaluate the fine structure of Sn$^{11+...14+}$ ions. These ions are essential in bright extreme-ultraviolet (EUV) plasma-light sources for next-generation nanolithography, but their complex electronic structure is an open challenge for both theory and experiment. We combine optical spectroscopy of magnetic dipole $M1$ transitions, in a wavelength range covering 260\\,nm to 780\\,nm, with charge-state selective ionization in an electron beam ion trap. Our measurements confirm the predictive power of \\emph{ab initio} calculations based on Fock space coupled cluster theory. We validate our line identification using semi-empirical Cowan calculations with adjustable wavefunction parameters. Available Ritz combinations further strengthen our analysis. Comparison with previous work suggests that line identifications in the EUV need to be revisited.

  18. Surface treatment of 0.20% C carbon steel by high-current pulsed electron beam

    Institute of Scientific and Technical Information of China (English)

    XU Guo-cheng; FU Shi-you; GUAN Qing-feng

    2006-01-01

    A high-current pulsed electron beam(HCPEB) generated on the system of Nadezhda-2 was applied to improve the microstructure and performance of 0.20% C low carbon steel. Surface layers of the samples bombarded by explosive electron beam at different pulses was observed by using electron microscopy. The physical model of the thermal-stress process and related modification mechanism as a result of HCPEB irradiation was also investigated. After HCPEB post treatments, obvious changes in microstructure and significant hardening occur in the depth of 200-250 μm from the surface after HCPEB irradiation. Rapid heating and subsequent rapid solidification induce heavy plastic deformation, which results in that the laminated structure of pearlite is substituted by dispersive rounded-like cementites in the near-surface. The effect of HCPEB treatment can reach more than 500 m depth from the surface. The original crystalline structure is changed to a different degree that grows with the numbers of bombardment, and in the surface layer amorphous states and nanocrystaline structures consisting of grains of γ-phase and cementite are found. The violent stress induced by HCPEB irradiation is the origin of the nanostructured and amorphous structure formation.

  19. A feasibility study on L-[1-carbon-11]tyrosine and L-[methyl-carbon-11]methionine to assess liver protein synthesis by PET

    NARCIS (Netherlands)

    Ishiwata, K; Enomoto, K; Elsinga, PH; Senda, M; Okazumi, SI; Isono, K; Paans, AMJ; Vaalburg, W

    1996-01-01

    We studied the potential of L-[1-C-11]tyrosine ([1-C-11]Tyr) and L-[methyl-C-11]methionine ([Me-C-11]Met) as tracers for measuring protein synthesis rate (PSR) in the liver by PET and proposed their metabolic models. Methods: In the liver and plasma of control and cycloheximide-treated mice injected

  20. Integration of carbon nanotubes with semiconductor technology: fabrication of hybrid devices by III–V molecular beam epitaxy

    DEFF Research Database (Denmark)

    Stobbe, Søren; Lindelof, P. E.; Nygård, J.

    2006-01-01

    on incorporation of singlewall nanotubes in III–V semiconductor heterostructures grown by molecular beam epitaxy (MBE). We demonstrate that singlewall carbon nanotubes can be overgrown using MBE; electrical contacts to the nanotubes are obtained by GaMnAs grown at 250 °C. The resulting devices can exhibit field...

  1. Radiosensitivity of pimonidazole-unlabelled intratumour quiescent cell population to γ-rays, accelerated carbon ion beams and boron neutron capture reaction.

    OpenAIRE

    Masunaga, S; Sakurai, Y.; Tanaka, H.; Hirayama, R; Matsumoto, Y; Uzawa, A; Suzuki, M.; Kondo, N; Narabayashi, M.; Maruhashi, A; Ono, K.

    2013-01-01

    [Objectives] To detect the radiosensitivity of intratumour quiescent (Q) cells unlabelled with pimonidazole to accelerated carbon ion beams and the boron neutron capture reaction (BNCR). [Methods] EL4 tumour-bearing C57BL/J mice received 5-bromo-2′-deoxyuridine (BrdU) continuously to label all intratumour proliferating (P) cells. After the administration of pimonidazole, tumours were irradiated with γ-rays, accelerated carbon ion beams or reactor neutron beams with the prior administration of...

  2. Conversion from dose-to-graphite to dose-to-water in an 80 MeV/A carbon ion beam.

    Science.gov (United States)

    Rossomme, S; Palmans, H; Shipley, D; Thomas, R; Lee, N; Romano, F; Cirrone, P; Cuttone, G; Bertrand, D; Vynckier, S

    2013-08-21

    Based on experiments and numerical simulations, a study is carried out pertaining to the conversion of dose-to-graphite to dose-to-water in a carbon ion beam. This conversion is needed to establish graphite calorimeters as primary standards of absorbed dose in these beams. It is governed by the water-to-graphite mass collision stopping power ratio and fluence correction factors, which depend on the particle fluence distributions in each of the two media. The paper focuses on the experimental and numerical determination of this fluence correction factor for an 80 MeV/A carbon ion beam. Measurements have been performed in the nuclear physics laboratory INFN-LNS in Catania (Sicily, Italy). The numerical simulations have been made with a Geant4 Monte Carlo code through the GATE simulation platform. The experimental data are in good agreement with the simulated results for the fluence correction factors and are found to be close to unity. The experimental values increase with depth reaching 1.010 before the Bragg peak region. They have been determined with an uncertainty of 0.25%. Different numerical results are obtained depending on the level of approximation made in calculating the fluence correction factors. When considering carbon ions only, the difference between measured and calculated values is maximal just before the Bragg peak, but its value is less than 1.005. The numerical value is close to unity at the surface and increases to 1.005 near the Bragg peak. When the fluence of all charged particles is considered, the fluence correction factors are lower than unity at the surface and increase with depth up to 1.025 before the Bragg peak. Besides carbon ions, secondary particles created due to nuclear interactions have to be included in the analysis: boron ions ((10)B and (11)B), beryllium ions ((7)Be), alpha particles and protons. At the conclusion of this work, we have the conversion of dose-to-graphite to dose-to-water to apply to the response of a graphite

  3. Carbon-11 labeled diacylglycerol for signal transduction imaging by positron CT. Evaluation of the quality and safety for clinical use

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Ryou [Nishijin Hospital, Kyoto (Japan); Imahori, Yoshio; Ido, Tatsuo [and others

    1995-02-01

    To elucidate the synaptic transmission in the neural system, we have been developing fundamental studies for intracellular signaling. For clinical application of carbon-11 labeled diacylglycerol (1-[1-{sup 11}C]butyryl-2-palmitoyl-rac-glycerol: {sup 11}C-DAG) using positron emission computed tomography (PET), we evaluated the quality and the safety of {sup 11}C-DAG as the solution for injection. As a result, {sup 11}C-DAG was synthesized within 50 minutes, including the preparation step for injection. The half life time and energy spectrum of {sup 11}C-DAG were the same as the physical character of carbon-11, and other radioisotopes were not detected. In the quality control, {sup 11}C-DAG solution was negative in the examination of bacterial contamination and the pyrogen test in three successive synthesis procedures. In the acute toxicity test by administration of {sup 11}C-DAG and 100 {mu}mol/kg of non-radioactive DAG to the rat intravenously, the systemic condition of the rat was not changed and no abnormalities were found in any organ 24 hours after administration. These findings indicated the safety of {sup 11}C-DAG solution. Clinical application of {sup 11}C-DAG using positron emission tomography may be useful to elucidate the dysfunction of intracellular signaling in disorders of higher cortical function such as Alzheimer disease. (author).

  4. One-dimensional carbon nanostructures for terahertz electron-beam radiation

    Science.gov (United States)

    Tantiwanichapan, Khwanchai; Swan, Anna K.; Paiella, Roberto

    2016-06-01

    One-dimensional carbon nanostructures such as nanotubes and nanoribbons can feature near-ballistic electronic transport over micron-scale distances even at room temperature. As a result, these materials provide a uniquely suited solid-state platform for radiation mechanisms that so far have been the exclusive domain of electron beams in vacuum. Here we consider the generation of terahertz light based on two such mechanisms, namely, the emission of cyclotronlike radiation in a sinusoidally corrugated nanowire (where periodic angular motion is produced by the mechanical corrugation rather than an externally applied magnetic field), and the Smith-Purcell effect in a rectilinear nanowire over a dielectric grating. In both cases, the radiation properties of the individual charge carriers are investigated via full-wave electrodynamic simulations, including dephasing effects caused by carrier collisions. The overall light output is then computed with a standard model of charge transport for two particularly suitable types of carbon nanostructures, i.e., zigzag graphene nanoribbons and armchair single-wall nanotubes. Relatively sharp emission peaks at geometrically tunable terahertz frequencies are obtained in each case. The corresponding output powers are experimentally accessible even with individual nanowires, and can be scaled to technologically significant levels using array configurations. These radiation mechanisms therefore represent a promising paradigm for light emission in condensed matter, which may find important applications in nanoelectronics and terahertz photonics.

  5. Increased Tensile Strength of Carbon Nanotube Yarns and Sheets through Chemical Modification and Electron Beam Irradiation

    Science.gov (United States)

    Miller, Sandi G.; Williams, Tiffany S.; Baker, James S.; Sola, Francisco; Lebron-Colon, Marisabel; McCorkle, Linda S.; Wilmoth, Nathan G.; Gaier, James; Chen, Michelle; Meador, Michael A.

    2014-01-01

    The inherent strength of individual carbon nanotubes offers considerable opportunity for the development of advanced, lightweight composite structures. Recent work in the fabrication and application of carbon nanotube (CNT) forms such as yarns and sheets has addressed early nanocomposite limitations with respect to nanotube dispersion and loading; and has pushed the technology toward structural composite applications. However, the high tensile strength of an individual CNT has not directly translated to macro-scale CNT forms where bulk material strength is limited by inter-tube electrostatic attraction and slippage. The focus of this work was to assess post processing of CNT sheet and yarn to improve the macro-scale strength of these material forms. Both small molecule functionalization and e-beam irradiation was evaluated as a means to enhance tensile strength and Youngs modulus of the bulk CNT material. Mechanical testing results revealed a tensile strength increase in CNT sheets by 57 when functionalized, while an additional 48 increase in tensile strength was observed when functionalized sheets were irradiated; compared to unfunctionalized sheets. Similarly, small molecule functionalization increased yarn tensile strength up to 25, whereas irradiation of the functionalized yarns pushed the tensile strength to 88 beyond that of the baseline yarn.

  6. Measurement of large angle fragments induced by 400 MeV n-1 carbon ion beams

    Science.gov (United States)

    Aleksandrov, Andrey; Consiglio, Lucia; De Lellis, Giovanni; Di Crescenzo, Antonia; Lauria, Adele; Montesi, Maria Cristina; Patera, Vincenzo; Sirignano, Chiara; Tioukov, Valeri

    2015-09-01

    The use of carbon ion beams in radiotherapy presents significant advantages when compared to traditional x-ray. In fact, carbon ions deposit their energy inside the human body at the end of their range, the Bragg peak. Unlike x-ray beams, where the energy deposition decreases exponentially inside the irradiated volume, the shape of carbon beams is sharp and focused. Advantages are an increased energy released in the cancer volume while minimizing the irradiation to healthy tissues. Currently, the use of carbon beams is limited by the poor knowledge we have about the effects of the secondary fragments on the irradiated tissues. The secondary particles produced and their angular distribution is crucial to determine the global dose deposition. The knowledge of the flux of secondary particles plays a key role in the real time monitoring of the dose profile in hadron therapy. We present a detector based on nuclear emulsions for fragmentation measurements that performs a sub-micrometric tridimensional spatial resolution, excellent multi-particle separation and large angle track recognition. Nuclear emulsions are assembled in order to realize a hybrid detector (emulsion cloud chamber (ECC)) made of 300 μm nuclear emulsion films alternated with lead as passive material. Data reported here have been obtained by exposing two ECC detectors to the fragments produced by a 400 MeV n-1 12C beam on a composite target at the GSI laboratory in Germany. The ECC was exposed inside a more complex detector, named FIRST, in order to collect fragments with a continuous angular distribution in the range 47°-81° with respect to the beam axis. Results on the angular distribution of fragments as well as their momentum estimations are reported here.

  7. Development and characterization of a 2D scintillation detector for quality assurance in scanned carbon ion beams

    Science.gov (United States)

    Tamborini, A.; Raffaele, L.; Mirandola, A.; Molinelli, S.; Viviani, C.; Spampinato, S.; Ciocca, M.

    2016-04-01

    At the Centro Nazionale di Adroterapia Oncologica (CNAO Foundation), a two-dimensional high resolution scintillating dosimetry system has been developed and tested for daily Quality Assurance measurements (QA) in carbon ion radiotherapy with active scanning technique, for both single pencil beams and scanned fields produced by a synchrotron accelerator. The detector consists of a thin plane organic scintillator (25×25 cm2, 2 mm thick) coupled with a high spatial resolution CCD camera (0.25 mm) in a light-tight box. A dedicated Labview software was developed for image acquisition triggered with the beam extraction, data post-processing and analysis. The scintillator system was preliminary characterized in terms of short-term reproducibility (found to be within±0.5%), linearity with the number of particles (linear fit χ2 = 0.996) and dependence on particle flux (measured to be < 1.5 %). The detector was then tested for single beam spot measurements (Full Width at Half Maximum and position) and for 6×6 cm2 reference scanned field (determination of homogeneity) for carbon ions with energy from 115 MeV/u up to 400 MeV/u. No major differences in the investigated beam parameters measured with scintillator system and the radiochromic EBT3 reference films were observed. The system allows therefore real-time monitoring of the carbon ion beam relevant parameters, with a significant daily time saving with respect to films currently used. The results of this study show the suitability of the scintillation detector for daily QA in a carbon ion facility with an active beam delivery system.

  8. Measurement of large angle fragments induced by 400 MeV n−1 carbon ion beams

    International Nuclear Information System (INIS)

    The use of carbon ion beams in radiotherapy presents significant advantages when compared to traditional x-ray. In fact, carbon ions deposit their energy inside the human body at the end of their range, the Bragg peak. Unlike x-ray beams, where the energy deposition decreases exponentially inside the irradiated volume, the shape of carbon beams is sharp and focused. Advantages are an increased energy released in the cancer volume while minimizing the irradiation to healthy tissues. Currently, the use of carbon beams is limited by the poor knowledge we have about the effects of the secondary fragments on the irradiated tissues. The secondary particles produced and their angular distribution is crucial to determine the global dose deposition. The knowledge of the flux of secondary particles plays a key role in the real time monitoring of the dose profile in hadron therapy.We present a detector based on nuclear emulsions for fragmentation measurements that performs a sub-micrometric tridimensional spatial resolution, excellent multi-particle separation and large angle track recognition. Nuclear emulsions are assembled in order to realize a hybrid detector (emulsion cloud chamber (ECC)) made of 300 μm nuclear emulsion films alternated with lead as passive material.Data reported here have been obtained by exposing two ECC detectors to the fragments produced by a 400 MeV n−1 12C beam on a composite target at the GSI laboratory in Germany. The ECC was exposed inside a more complex detector, named FIRST, in order to collect fragments with a continuous angular distribution in the range 47°–81° with respect to the beam axis. Results on the angular distribution of fragments as well as their momentum estimations are reported here. (paper)

  9. Tracers development for the PET study of nicotinic receptors: [11C]-mecamylamine and [11C]-SIB 1553A. Tritium and carbon-11 radiolabelling of a serine proteinase inhibitor: the t-PAstop

    International Nuclear Information System (INIS)

    In order to develop radiotracers for the Positron Emission Tomography (PET), we labelled both the mecamylamine and SIB-1553A with carbon-11 to study the nicotinic cholinergic receptors (nAChRs). The radiosynthesis of [11C]-t-PAstop and the labelling with tritium of one analogue were realized for cerebral ischemia PET studies. The [11C]-mecamylamine, a non-competitive and non-selective nAChRs antagonist was synthesized in 45 min via a N-[11C]-methylation reaction. In the rat brain, the ex vivo studies showed no radio-metabolite 45 min after the injection of [11C]-mecamylamine. The uptake kinetics in the rat brain or in vivo by PET in the anesthetized baboon or in the conscious monkey, reached a plateau around 45-50 min after injection. However, the saturation or displacement experiments did not permit to exhibit nor a significant difference of labelling between the different cerebral regions nor a specific uptake. In consequence, the [11C]-mecamylamine was not an appropriate radioligand for nAChRs PET study. The labelling of [11C]-SIB 1553A, a selective agonist for the nicotinic β4 subunit, required the synthesis in 5 steps (56% overall yield) of precursor for the incorporation of carbon-11. The radiosynthesis was performed in 36 min by a N-[11C]-methylation reaction (yield: 75%). The [11C]-t-PAstop was obtained from [11C]-KCN with yields from 80 to 90%. For the first time with carbon-11, the formation of an amidine group was realized from a nitrile group. The labelling by isotopic exchange of hydrogen by tritium of the t-PAstop did not permit to obtain the [3H]-t-PAstop but a tritiated analogue. This compound will be used to study its vectorization by micro-encapsulation. (author)

  10. Dynamic response of RC beams strengthened with near surface mounted Carbon-FRP rods subjected to damage

    Science.gov (United States)

    Capozucca, R.; Blasi, M. G.; Corina, V.

    2015-07-01

    Near surface mounted (NSM) technique with fiber reinforced polymer (FRP) is becoming a common method in the strengthening of concrete beams. The availability of NSM FRP technique depends on many factors linked to materials and geometry - dimensions of the rods used, type of FRP material employed, rods’ surface configuration, groove size - and to adhesion between concrete and FRP rods. In this paper detection of damage is investigated measuring the natural frequency values of beam in the case of free-free ends. Damage was due both to reduction of adhesion between concrete and carbon-FRP rectangular and circular rods and cracking of concrete under static bending tests on beams. Comparison between experimental and theoretical frequency values evaluating frequency changes due to damage permits to monitor actual behaviour of RC beams strengthened by NSM CFRP rods.

  11. Robust, easily shaped, and epoxy-free carbon-fiber-aluminum cathodes for generating high-current electron beams

    Science.gov (United States)

    Liu, Lie; Li, Limin; Wen, Jianchun; Wan, Hong

    2009-02-01

    This paper presents the construction of carbon-fiber-aluminum (CFA) cathode by squeezing casting and its applications for generating high-current electron beams to drive high-power microwave sources. The fabrication process avoided using epoxy, a volatile deteriorating the vacuum system. These cathodes had a higher hardness than conventional aluminum, facilitating machining. After surface treatment, carbon fibers became the dominator determining emission property. A multineedle CFA cathode was utilized in a triode virtual cathode oscillator (vircator), powered by a ˜450 kV, ˜400 ns pulse. It was found that 300-400 MW, ˜250 ns microwave was radiated at a dominant frequency of 2.6 GHz. Further, this cathode can endure high-current-density emission without detectable degradation in performance as the pulse shot proceeded, showing the robust nature of carbon fibers as explosive emitters. Overall, this new class of cold cathodes offers a potential prospect of developing high-current electron beam sources.

  12. Deposition of Diamond-Like carbon Films by High-Intensity Pulsed Ion Beam Ablation at Various Substrate Temperatures

    Institute of Scientific and Technical Information of China (English)

    梅显秀; 刘振民; 马腾才; 董闯

    2003-01-01

    Diamond-like carbon (DLC) films have been deposited on to Si substrates at substrate temperatures from 25℃to 400 ℃ by a high-intensity pulsed-ion-beam (HIPIB) ablation deposition technique. The formation of DLC is confirmed by Raman spectroscopy. According to an x-ray photoelectron spectroscopy analysis, the concentration of spa carbon in the films is about 40% when the substrate temperature is below 300 ℃. With increasing substrate temperature from 25 ℃ to 400 ℃, the concentration of sp3 carbon decreases from 43% to 8%. In other words,sp3 carbon is graphitized into sp2 carbon when the substrate temperature is above 300 ℃. The results of xray diffraction and atomic force microscopy show that, with increasing the substrate temperature, the surface roughness and the friction coefficient increase, and the microhardness and the residual stress of the films decrease.

  13. Chemical effects of 100 keV primary electrons in an e-beam sustained carbon dioxide laser discharge

    International Nuclear Information System (INIS)

    The dissociation of carbon dioxide and the reaction of carbon monoxide with oxygen caused by a high-energy (approx 100 kev) electron beam in a typical carbon dioxide laser gas mixture has been observed. The variation of reaction rates with electron energy and current, interelectrode spacing, and gas composition has been studied. The rates of both processes suggest that the reactions are caused by unthermalized secondary electrons. The conditions were investigated under which the carbon monoxide oxidation reaction could be used to offset dissociation in a laser and thus prolong its sealed life. For a secondary to primary current ratio of one hundred this condition should be satisfied for any practical device. A sealed run was carried out which demonstrated that dissociation by secondary electrons could be offset by the oxidation of carbon monoxide by the primary electrons. (author)

  14. Carbon-11 labeled cathepsin K inhibitors: syntheses and preliminary in vivo evaluation.

    Science.gov (United States)

    Rodnick, Melissa E; Shao, Xia; Kozloff, Kenneth M; Scott, Peter J H; Kilbourn, Michael R

    2014-01-01

    Cathepsin K is a cysteine peptidase primarily located in osteoclasts, cells involved in normal growth and remodeling of bone but that are also responsible for bone loss in osteolytic diseases such as osteoporosis. In vivo imaging of cathepsin K may provide a method to assess changes in osteoclast numbers in such disease states. To that end, two high-affinity and selective cathepsin K inhibitors were radiolabeled with carbon-11. In vivo microPET imaging studies demonstrated uptake and prolonged retention of radioactivity in actively growing or remodeling bone regions (e.g., distal ulnar, carpal, distal and proximal humeral, distal femur, proximal tibia, tail vertebrae). Uptake into bone could be blocked by pre- or co-injection of unlabeled ligand, supporting a specific and saturable binding mechanism for radiotracer localization. These proof-of-concept studies indicate that radiolabeled cathepsin K inhibitors may have potential as in vivo imaging radiotracers for assessing changes of osteoclast numbers in osteolytic diseases.

  15. Synthesis and positron emission tomography studies of carbon-11-labeled imatinib (Gleevec)

    Energy Technology Data Exchange (ETDEWEB)

    Kil, Kun-Eek [Medical Department, Brookhaven National Laboratory, Upton, NY 11973 (United States); Department of Chemistry, State University of New York at Stony Brook, Stony Brook, NY 11794-3400 (United States); Ding Yushin [Department of Radiology, Yale University School of Medicine, New Haven, CT 06520-8048 (United States); Lin Kuoshyan [Department of Radiology, University of Pittsburgh, Pittsburgh, PA 15213 (United States); Alexoff, David [Medical Department, Brookhaven National Laboratory, Upton, NY 11973 (United States); Kim, Sung Won [Medical Department, Brookhaven National Laboratory, Upton, NY 11973 (United States); Department of Chemistry, State University of New York at Stony Brook, Stony Brook, NY 11794-3400 (United States); Shea, Colleen [Medical Department, Brookhaven National Laboratory, Upton, NY 11973 (United States); Xu Youwen [Medical Department, Brookhaven National Laboratory, Upton, NY 11973 (United States); Muench, Lisa [Medical Department, Brookhaven National Laboratory, Upton, NY 11973 (United States); Fowler, Joanna S. [Medical Department, Brookhaven National Laboratory, Upton, NY 11973 (United States) and Department of Chemistry, State University of New York at Stony Brook, Stony Brook, NY 11794-3400 (United States)]. E-mail: fowler@bnl.gov

    2007-02-15

    Introduction: Imatinib mesylate (Gleevec) is a well known drug for treating chronic myeloid leukemia and gastrointestinal stromal tumors. Its active ingredient, imatinib ([4-[(4-methyl-1-piperazinyl)methyl]-N-[4-methyl-3-[[4-(3-pyridyl) -2-pyrimidinyl]amino]phenyl]benzamide), blocks the activity of several tyrosine kinases. Here we labeled imatinib with carbon-11 as a tool for determining the drug distribution and pharmacokinetics of imatinib, and we carried out positron emission tomography (PET) studies in baboons. Methods: [N-{sup 11}C-methyl]imatinib was synthesized from [{sup 11}C]methyl iodide and norimatinib was synthesized by the demethylation of imatinib (isolated from Gleevec tablets) according to a patent procedure [Collins JM, Klecker RW Jr, Anderson LW. Imaging of drug accumulation as a guide to antitumor therapy. US Patent 20030198594A1, 2003]. Norimatinib was also synthesized from the corresponding amine and acid. PET studies were carried out in three baboons to measure pharmacokinetics in the brain and peripheral organs and to determine the effect of a therapeutic dose of imatinib. Log D and plasma protein binding were also measured. Results: [N-{sup 11}C-methyl]imatinib uptake in the brain is negligible (consistent with P-glycoprotein-mediated efflux); it peaks and clears rapidly from the heart, lungs and spleen. Peak uptake and clearance occur more slowly in the liver and kidneys, followed by accumulation in the gallbladder and urinary bladder. Pretreatment with imatinib did not change uptake in the heart, lungs, kidneys and spleen, and increased uptake in the liver and gallbladder. Conclusions: [N-{sup 11}C-methyl]imatinib has potential for assessing the regional distribution and kinetics of imatinib in the human body to determine whether the drug targets tumors and to identify other organs to which the drug or its labeled metabolites distribute. Paired with tracers such as 2'deoxy-2'-[{sup 18}F]fluoro-D-glucose ({sup 18}FDG) and 3&apos

  16. Studies of cryocooler based cryosorption pump with activated carbon panels operating at 11K

    Science.gov (United States)

    Kasthurirengan, S.; Behera, Upendra; Gangradey, Ranjana; Udgata, Swarup; Krishnamoorthy, V.

    2012-11-01

    Cryosorption pump is the only solution for pumping helium and hydrogen in fusion reactors. It is chosen because it offers highest pumping speed as well as the only suitable pump for the harsh environments in a tokamak. Towards the development of such cryosorption pumps, the optimal choice of the right activated carbon panels is essential. In order to characterize the performance of the panels with indigenously developed activated carbon, a cryocooler based cryosorption pump with scaled down sizes of panels is experimented. The results are compared with the commercial cryopanel used in a CTI cryosorption (model: Cryotorr 7) pump. The cryopanel is mounted on the cold head of the second stage GM cryocooler which cools the cryopanel down to 11K with first stage reaching about ~50K. With no heat load, cryopump gives the ultimate vacuum of 2.1E-7 mbar. The pumping speed of different gases such as nitrogen, argon, hydrogen, helium are tested both on indigenous and commercial cryopanel. These studies serve as a bench mark towards the development of better cryopanels to be cooled by liquid helium for use with tokamak.

  17. Beam pen lithography based on arrayed polydimethylsiloxane (PDMS) micro-pyramids spin-coated with carbon black photo-resist

    International Nuclear Information System (INIS)

    This paper presents a new method for preparing a polydimethylsiloxane (PDMS) mold which can be used in beam pen lithography for patterning a photo-resist (PR) layer in a maskless and direct-write manner. The PDMS mold contains an array of micro-pyramids on its surface and is spin-coated with a layer of carbon black PR which is an opaque material. Because of the arrayed pyramidal surface profile, the spin-coated carbon black PR layer is either thinner at the pyramid tips or does not cover the tips at all, which allows ultraviolet (UV) light to pass through the PDMS mold and forms an array of UV beams. The aperture size of the UV beams can be controlled at a sub-micrometer scale and hence can be used for micro/nano-patterning. Applying this carbon black-PR-coated PDMS mold in beam pen lithography along with a metal lift-off process, various metal dot patterns with a dot-size around 400 to 500 nm are successfully obtained. Both experimental results and theoretical analysis are given along with possible improvements and applications in the future. (paper)

  18. Structural changes of electron and ion beam-deposited contacts in annealed carbon-based electrical devices

    KAUST Repository

    Batra, Nitin M

    2015-10-09

    The use of electron and ion beam deposition to make devices containing discrete nanostructures as interconnectors is a well-known nanofabrication process. Classically, one-dimensional materials such as carbon nanotubes (CNTs) have been electrically characterized by resorting to these beam deposition methods. While much attention has been given to the interconnectors, less is known about the contacting electrodes (or leads). In particular, the structure and chemistry of the electrode–interconnector interface is a topic that deserves more attention, as it is critical to understand the device behavior. Here, the structure and chemistry of Pt electrodes, deposited either with electron or ion beams and contacted to a CNT, are analyzed before and after thermally annealing the device in a vacuum. Free-standing Pt nanorods, acting as beam-deposited electrode models, are also characterized pre- and post-annealing. Overall, the as-deposited leads contain a non-negligible amount of amorphous carbon that is consolidated, upon heating, as a partially graphitized outer shell enveloping a Pt core. This observation raises pertinent questions regarding the definition of electrode–nanostructure interfaces in electrical devices, in particular long-standing assumptions of metal-CNT contacts fabricated by direct beam deposition methods.

  19. Biodistribution of a positron-emitting suicide inactivator of monoamine oxidase, carbon-11 pargyline, in mice and a rabbit

    International Nuclear Information System (INIS)

    Carbon-11 (11C) pargyline, which is a suicide inactivator of Type B monoamine oxidase (MAO), was synthesized by the reaction of N-demethylpargyline with 11CH3l. Biodistribution was investigated in mice, and positron tomographic images of the heart and lung in a rabbit were obtained. The distribution of 11C after administration of [11C]pargyline was measured in several organs and blood at various time intervals. After 30 min its concentrations in the organs were constant. Subcellular distribution studies in the brain, lung, liver, and kidney showed that 59-70% of the 11C became acid-insoluble and 9-33% was present in the crude mitochondrial fraction at 60 min after injection. The uptakes of the 11C in each organ except for the kidney and spleen seemed to correlate with the in vitro enzymatic activity of Type B MAO. At high loading dose a nonspecific uptake was observed

  20. Nitrogen laser with a pulse repetition rate of 11 kHz and a beam divergence of 0.5 mrad

    International Nuclear Information System (INIS)

    A repetitively pulsed high-frequency UV nitrogen laser based on magnetic pulse compression (MPC) circuit is developed. The special characteristics of laser operation at pulse repetition rates up to 11 kHz are studied. Lasing with an average power of 1.4 W for a beam divergence of less than 0.5 mrad is obtained. (lasers)

  1. Characterization of nanometer-scale porosity in reservoir carbonate rock by focused ion beam-scanning electron microscopy.

    Science.gov (United States)

    Bera, Bijoyendra; Gunda, Naga Siva Kumar; Mitra, Sushanta K; Vick, Douglas

    2012-02-01

    Sedimentary carbonate rocks are one of the principal porous structures in natural reservoirs of hydrocarbons such as crude oil and natural gas. Efficient hydrocarbon recovery requires an understanding of the carbonate pore structure, but the nature of sedimentary carbonate rock formation and the toughness of the material make proper analysis difficult. In this study, a novel preparation method was used on a dolomitic carbonate sample, and selected regions were then serially sectioned and imaged by focused ion beam-scanning electron microscopy. The resulting series of images were used to construct detailed three-dimensional representations of the microscopic pore spaces and analyze them quantitatively. We show for the first time the presence of nanometer-scale pores (50-300 nm) inside the solid dolomite matrix. We also show the degree of connectivity of these pores with micron-scale pores (2-5 μm) that were observed to further link with bulk pores outside the matrix.

  2. Flexural behaviour of partially bonded carbon fibre reinforced polymers strengthened concrete beams: Application to fire protection systems design

    International Nuclear Information System (INIS)

    Highlights: • The mechanical behaviour of partially bonded CFRP strengthened beams was modelled. • Two dimensional non-linear finite element models were developed. • Partially bonded beams can present similar flexural strength to fully bonded ones. • Relations between the bonded length and the strength reduction were proposed. • The proposed relations were used for the design of fire protection systems. - Abstract: Recent fire resistance tests on reinforced concrete (RC) beams strengthened with carbon fibre reinforced polymers (CFRP) laminates showed that it is possible to attain considerable fire endurance provided that thermal insulation is applied at the anchorage zones of the strengthening system. With such protection, although the CFRP laminate prematurely debonds in the central part of the beam, it transforms into a cable fixed at the extremities until one of the anchorage zones loses its bond strength. The main objective of this paper is to propose a simplified methodology for the design of fire protection systems for CFRP strengthened-RC beams, which is based on applying thicker insulation at the anchorage zones (promoting the above mentioned “cable behaviour”) and a thinner one at the current zone (avoiding tensile rupture of the carbon fibres). As a first step towards the validation of this methodology, finite element (FE) models were developed to simulate the flexural behaviour at ambient temperature of full-scale RC beams strengthened with CFRP laminates according to the externally bonded reinforcement (EBR) and near surface mounted (NSM) techniques, in both cases fully or partially bonded (the latter simulating the cable). The FE models were calibrated with results of 4-point bending tests on small-scale beams and then extended for different beam geometries, with spans (L) varying from 2 m to 5 m, in which the influence of the CFRP bonded length (lb) and the loading type (point or uniformly distributed) on the strength reduction was

  3. Water equivalent thickness values of materials used in beams of protons, helium, carbon and iron ions

    OpenAIRE

    Zhang, Rui; Taddei, Phillip J.; Fitzek, Markus M.; Newhauser, Wayne D.

    2010-01-01

    Heavy charged particle beam radiotherapy for cancer is of increasing interest because it delivers a highly conformal radiation dose to the target volume. Accurate knowledge of the range of a heavy charged particle beam after it penetrates a patient’s body or other materials in the beam line is very important and is usually stated in terms of the water equivalent thickness (WET). However, methods of calculating WET for heavy charged particle beams are lacking. Our objective was to test several...

  4. Carbon beam extraction with 14.5 GHz electron cyclotron resonance ion source at Korea Atomic Energy Research Institute

    Science.gov (United States)

    Lee, Cheol Ho; Oh, Byung-Hoon; Chang, Dae-Sik; Jeong, Sun-Chan

    2014-02-01

    A 14.5 GHz Electron Cyclotron Resonance ion source (ECRIS) has been made to produce C4+ beam for using a carbon therapy facility and recently tested at KAERI. Highly charged carbon ions have been successfully extracted. When using only CO2 gas, the beam current of C4+ was almost 14 μA at 15 kV extraction voltage. To get higher current of the C4+ beam, while optimizing confinement magnetic field configuration (e.g., axial strengths at minimum and extraction side), gas-mixing (CO2/He), and biased disk were introduced. When the gas mixing ratio of the CO2/He gas is 1:8 at an operational pressure of 5 × 10-7 mbar and the disk was biased to -150 V relative to the ion source body, the highest current of the C4+ beam was achieved to be 50 μA, more than three times higher than previously observed only with CO2 gas. Some details on the operating conditions of the ECRIS were discussed.

  5. Evaluation of beam delivery and ripple filter design for non-isocentric proton and carbon ion therapy

    International Nuclear Information System (INIS)

    This study aims at selecting and evaluating a ripple filter design compatible with non-isocentric proton and carbon ion scanning beam treatment delivery for a compact nozzle. The use of non-isocentric treatments when the patient is shifted as close as possible towards the nozzle exit allows for a reduction in the air gap and thus an improvement in the quality of scanning proton beam treatment delivery. Reducing the air gap is less important for scanning carbon ions, but ripple filters are still necessary for scanning carbon ion beams to reduce the number of energy steps required to deliver homogeneous SOBP. The proper selection of ripple filters also allows a reduction in the possible transverse and depth-dose inhomogeneities that could appear in non-isocentric conditions in particular.A thorough review of existing ripple filter designs over the past 16 years is performed and a design for non-isocentric treatment delivery is presented. A unique ripple filter quality index (QIRiFi) independent of the particle type and energy and representative of the ratio between energy modulation and induced scattering is proposed. The Bragg peak width evaluated at the 80% dose level (BPW80) is proposed to relate the energy modulation of the delivered Bragg peaks and the energy layer step size allowing the production of homogeneous SOBP. Gate/Geant4 Monte Carlo simulations have been validated for carbon ion and ripple filter simulations based on measurements performed at CNAO and subsequently used for a detailed analysis of the proposed ripple filter design.A combination of two ripple filters in a series has been validated for non-isocentric delivery and did not show significant transverse and depth-dose inhomogeneities. Non-isocentric conditions allow a significant reduction in the spot size at the patient entrance (up to 350% and 200% for protons and carbon ions with range shifter, respectively), and therefore in the lateral penumbra in the patients. (paper)

  6. Evaluation of beam delivery and ripple filter design for non-isocentric proton and carbon ion therapy

    Science.gov (United States)

    Grevillot, L.; Stock, M.; Vatnitsky, S.

    2015-10-01

    This study aims at selecting and evaluating a ripple filter design compatible with non-isocentric proton and carbon ion scanning beam treatment delivery for a compact nozzle. The use of non-isocentric treatments when the patient is shifted as close as possible towards the nozzle exit allows for a reduction in the air gap and thus an improvement in the quality of scanning proton beam treatment delivery. Reducing the air gap is less important for scanning carbon ions, but ripple filters are still necessary for scanning carbon ion beams to reduce the number of energy steps required to deliver homogeneous SOBP. The proper selection of ripple filters also allows a reduction in the possible transverse and depth-dose inhomogeneities that could appear in non-isocentric conditions in particular. A thorough review of existing ripple filter designs over the past 16 years is performed and a design for non-isocentric treatment delivery is presented. A unique ripple filter quality index (QIRiFi) independent of the particle type and energy and representative of the ratio between energy modulation and induced scattering is proposed. The Bragg peak width evaluated at the 80% dose level (BPW80) is proposed to relate the energy modulation of the delivered Bragg peaks and the energy layer step size allowing the production of homogeneous SOBP. Gate/Geant4 Monte Carlo simulations have been validated for carbon ion and ripple filter simulations based on measurements performed at CNAO and subsequently used for a detailed analysis of the proposed ripple filter design. A combination of two ripple filters in a series has been validated for non-isocentric delivery and did not show significant transverse and depth-dose inhomogeneities. Non-isocentric conditions allow a significant reduction in the spot size at the patient entrance (up to 350% and 200% for protons and carbon ions with range shifter, respectively), and therefore in the lateral penumbra in the patients.

  7. Influence of carbon on the giant magnetocaloric effect of LaFe11.7Si1.3

    Institute of Scientific and Technical Information of China (English)

    LI Junqin; LIU Fusheng; AO Weiqin; ZHUANG Yinghong; ZHOU Kaiwen

    2006-01-01

    The influences of carbon on phase formation, Curie temperature, and magnetic entropy change of the NaZn13-type LaFe11.7Si1.3 were investigated. Seven carbon-containing alloys, LaFe11.7Si1.3Cx with x = 0, 0.03, 0.06, 0.10, 0.20, 0.30, and 0.50, respectively, were prepared for this investigation. Experimental results show that addition of a small amount of carbon in LaFe11.7Si1.3 is favorable for the formation of the NaZn13-type structure of LaFe11.7Si1.3Cx. The lattice constant increases with C addition and x increases in the alloy because of the introduction of C as interstitial atoms. The Cu rie temperature of LaFe11.7Si1.3Cx increases from 194 K to 225 K as x increases from 0 to 0.5. Large magnetic entropy changes were observed in these carbon-hontaining alloys LaFe11.7Si1.3Cx because of their first-order structural/magnetic observed in the alloy with x = 0.06. The large magnetic-entropy changes corresponding to low magnetic field change, and the low cost of the material of LaFe11.7Si1.3Cx makes it a promising candidate to be used as magnetic refrigerants in the corresponding temperature range.

  8. Radiation protection problems in a laboratory for the labelling of molecules with carbon-11

    International Nuclear Information System (INIS)

    This paper shows that the qualities of carbon-11, especially its short half-life, which suit it so well for the labelling of radiopharmaceuticals prove to be a great handicap in the preparation of these substances. The operator has to make a fresh preparation for each examination and start with strong radioactivities (200 to 500 mCi) in order to obtain an adequate injected activity at the end of the process, the absorbed dose averaging 1.5 man-rem per manipulation at the fingertips. The development of an automatic preparation method involving as little manual interference as possible has halved the collective dose for twice the dose handled. The labelling of molecules used for diagnosis is now considered to take place under satisfactory radioprotection conditions. The fingertip irradiations are analysed in the light of CIPR recommendations, while regretting that in publication 26 this problem of partial external irradiation of the skin is not dealt with as clearly and precisely as before

  9. Regional myocardial oxygen consumption estimated by carbon-11 acetate and positron emission tomography before and after repetitive ischemia

    DEFF Research Database (Denmark)

    Kofoed, K F; Hansen, P R; Holm, S;

    2011-01-01

    Preserved myocardial oxygen consumption estimated by carbon 11-acetate and positron emission tomography (PET) in myocardial regions with chronic but reversibly depressed contractile function in patients with ischemic heart disease have been suggested to be caused by repeated short episodes of acute...

  10. Synthesis of suicide inhibitors of monoamine oxidase: carbon-11 labeled clorgyline, L-deprenyl and D-deprenyl

    International Nuclear Information System (INIS)

    The suicide inhibitors of monoamine oxidase type A and B, clorgyline and L-deprenyl have been labeled with carbon-11 by [11C]methylation of the norbases with [11C]H3I. The less active enantiomer of deprenyl (D-deprenyl) was also labeled using this procedure. The synthesis time was 35 minutes, the radiochemical yield was 25-40% and the specific activity was 0.8-2.0 Ci/μmol (calculated to EOB). Procedures for synthesis of the precursor norbases as well as the synthesis of unlabeled clorgyline, L-deprenyl and D-deprenyl are given. (author)

  11. Carbon ion beam treatment in patients with primary and recurrent sacrococcygeal chordoma

    Energy Technology Data Exchange (ETDEWEB)

    Uhl, Matthias; Jensen, Alexandra; Herfarth, Klaus [University of Heidelberg, Department of Radiation Oncology, Heidelberg (Germany); Heidelberg Ion Beam Therapy Center (HIT), Heidelberg (Germany); Welzel, Thomas [University of Heidelberg, Department of Radiation Oncology, Heidelberg (Germany); Ellerbrock, Malte; Haberer, Thomas [Heidelberg Ion Beam Therapy Center (HIT), Heidelberg (Germany); Jaekel, Oliver [University of Heidelberg, Department of Radiation Oncology, Heidelberg (Germany); Heidelberg Ion Beam Therapy Center (HIT), Heidelberg (Germany); German Cancer Research Center (dkfz), Heidelberg (Germany); Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg (Germany); Debus, Juergen [University of Heidelberg, Department of Radiation Oncology, Heidelberg (Germany); Heidelberg Ion Beam Therapy Center (HIT), Heidelberg (Germany); German Cancer Research Center (dkfz), Heidelberg (Germany); Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg (Germany); Deutsches Konsortium fuer Translationale Krebsforschung (DKTK), Heidelberg (Germany)

    2015-07-15

    The purpose of this work was to evaluate the results of high-dose radiation treatment using carbon ion therapy, alone or combined with intensity-modulated radiation treatment (IMRT), in patients with sacral chordoma. Between 2009 and 2012, 56 patients with sacral chordoma were treated in our center. The tumor was located above S3 in 33 patients and in S3 or below in 23 patients. In all, 41 patients received radiation therapy for the primary tumor, while 15 patients were treated for the recurrent tumor. Toxicity was measured using NCI CTCAE v.4.03. Local control (LC) and overall survival (OS) were evaluated with the Kaplan-Meier method. A total of 23 patients were irradiated with carbon ions in combination with photon IMRT, while 33 received carbon ion therapy only. Forty-three patients had a macroscopic tumor at treatment start with a median tumor size (GTV) of 244 ml (range 5-1188 ml). The median total dose was 66 Gy (range 60-74 Gy; RBE). After a median follow-up time of 25 months, the 2- and 3-year local control probability was 76 % and 53 %, respectively. The overall survival rate was 100 %. Treatment for primary tumor and male patients resulted in significant better local control. No higher toxicity occurred within the follow-up time. High-dose photon/carbon ion beam radiation therapy is safe and, especially for primary sacral chordomas, highly effective. A randomized trial is required to evaluate the role of primary definitive hypofractionated particle therapy compared with surgery with or without adjuvant radiotherapy. (orig.) [German] Evaluierung der Ergebnisse nach hochdosierter Kohlenstoffionentherapie, allein oder in Kombination mit einer intensitaetsmodulierten Photonenbestrahlung (IMRT), bei Patienten mit einem sakralen Chordom. Zwischen 2009 und 2012 wurden 56 Patienten mit sakralen Chordomen in unserem Zentrum behandelt. Der Tumor war bei 33 Patienten oberhalb von S3 und bei 23 Patienten auf Hoehe von S3 oder unterhalb davon lokalisiert. Insgesamt

  12. MODIFICATION OF CARBON STEEL BY LASER SURFACE MELTING: PART I: EFFECT OF LASER BEAM TRAVELLING SPEED ON MICROSTRUCTURAL FEATURES AND SURFACE HARDNESS

    OpenAIRE

    Hashem F. El-Labban; Abdelaziz, M.; Essam R.I. Mahmoud

    2013-01-01

    The present study aims to improve the surface hardness of carbon steel by application of laser surface melting of effective conditions. The travelling speed of laser beam during this treatment is one of the important treatment conditions. This study aims to investigate the effect of laser surface melting with different beam speeds on macro and microstructure as well as the hardness distribution through the thickness of carbon steel. To achieve this target, three different travelling speeds (1...

  13. Very high temperature chemical vapor deposition of new carbon thin films using organic semiconductor molecular beam sources

    Energy Technology Data Exchange (ETDEWEB)

    Noguchi, Takuya [Department of Chemistry, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033 (Japan); Shimada, Toshihiro, E-mail: shimada@chem.s.u-tokyo.ac.j [Department of Chemistry, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033 (Japan); Hanzawa, Akinori; Hasegawa, Tetsuya [Department of Chemistry, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033 (Japan)

    2009-11-30

    We carried out the preparation and characterization of new carbon films deposited using an organic molecular beam deposition apparatus with very high substrate temperature (from room temperature to 2670 K), which we newly developed. When we irradiated molecular beam of organic semiconductor perylene tetracarboxylic acid dianhydride (PTCDA) on Y{sub 0.07}Zr{sub 0.93}O{sub 2} (111) at 2170 K, a new carbon material was formed via decomposition and fusing of the molecules. The films were characterized with an atomic force microscope (AFM), Raman spectroscopy, X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). Zirconium carbide (ZrC) films were identified beneath the topmost carbon layer by XRD and XPS analyses, which results from chemical reactions of the substrate and the molecules. Partially graphitized aromatic rings of PTCDA were observed from Raman spectroscopy. The present technique - very high temperature chemical vapor deposition using organic semiconductor sources - will be useful to study a vast unexplored field of covalent carbon solids.

  14. Three ways to solve the orbit of KIC 11 558 725: a 10-day beaming sdB+WD binary with a pulsating subdwarf

    Science.gov (United States)

    Telting, J. H.; Østensen, R. H.; Baran, A. S.; Bloemen, S.; Reed, M. D.; Oreiro, R.; Farris, L.; Ottosen, T. A.; Aerts, C.; Kawaler, S. D.; Heber, U.; Prins, S.; Green, E. M.; Kalomeni, B.; O'Toole, S. J.; Mullally, F.; Sanderfer, D. T.; Smith, J. C.; Kjeldsen, H.

    2012-08-01

    The recently discovered subdwarf B (sdB) pulsator KIC 11 558 725 is one of the 16 pulsating sdB stars detected in the Kepler field. It features a rich g-mode frequency spectrum, with a few low-amplitude p-modes at short periods. This makes it a promising target for a seismic study aiming to constrain the internal structure of this star, and of sdB stars ingeneral. We have obtained ground-based spectroscopic radial-velocity measurements of KIC 11 558 725 based on low-resolution spectra in the Balmer-line region, spanning the 2010 and 2011 observing seasons. From these data we have discovered that KIC 11 558 725 is a binary with period P = 10.05 d, and that the radial-velocity amplitude of the sdB star is 58 km s-1. Consequently the companion of the sdB star has a minimum mass of 0.63 M⊙, and is therefore most likely an unseen white dwarf. We analyse the near-continuous 2010-2011 Kepler light curve to reveal the orbital Doppler-beaming effect, giving rise to light variations at the 238 ppm level, which is consistent with the observed spectroscopic orbital radial-velocity amplitude of the subdwarf. We use the strongest 70 pulsation frequencies in the Kepler light curve of the subdwarf as clocks to derive a third consistent measurement of the orbital radial-velocity amplitude, from the orbital light-travel delay. The orbital radius asdBsini = 11.5 R⊙ gives rise to a light-travel time delay of 53.6 s, which causes aliasing and lowers the amplitudes of the shortest pulsation frequencies, unless the effect is corrected for. We use our high signal-to-noise average spectra to study the atmospheric parameters of the sdB star, deriving Teff = 27 910 K andlog g = 5.41 dex, and find that carbon, nitrogen and oxygen are underabundant relative to the solar mixture. Furthermore, we analyse the Kepler light curve for its pulsational content and extract more than 160 significant frequencies.We investigate the pulsation frequencies for expected period spacings and rotational

  15. Effects of porous carbon additives and induced fluorine on low dielectric constant polyimide synthesized with an e-beam

    International Nuclear Information System (INIS)

    We report the synthesis of a polyimide matrix with a low dielectric constant for application as an intercalation material between metal interconnections in electronic devices. Porous activated carbon was embedded in the polyimide to reduce the dielectric constant, and a thin film of the complex was obtained using the spin-coating and e-beam irradiation methods. The surface of the thin film was modified with fluorine functional groups to impart water resistance and reduce the dielectric constant further. The water resistance was significantly improved by the modification with hydrophobic fluorine groups. The dielectric constant was effectively decreased by porous activated carbon. The fluorine modification also resulted in a low dielectric constant on the polyimide surface by reducing the polar surface free energy. The dielectric constant of polyimide film decreased from 2.98 to 1.9 by effects of porous activated carbon additive and fluorine surface modification.

  16. Friction and Wear of Ion-Beam-Deposited Diamondlike Carbon on Chemical-Vapor-Deposited, Fine-Grain Diamond

    Science.gov (United States)

    Miyoshi, Kazuhisa; Wu, Richard L. C.; Lanter, William C.

    1996-01-01

    Friction and wear behavior of ion-beam-deposited diamondlike carbon (DLC) films coated on chemical-vapor-deposited (CVD), fine-grain diamond coatings were examined in ultrahigh vacuum, dry nitrogen, and humid air environments. The DLC films were produced by the direct impact of an ion beam (composed of a 3:17 mixture of Ar and CH4) at ion energies of 1500 and 700 eV and an RF power of 99 W. Sliding friction experiments were conducted with hemispherical CVD diamond pins sliding on four different carbon-base coating systems: DLC films on CVD diamond; DLC films on silicon; as-deposited, fine-grain CVD diamond; and carbon-ion-implanted, fine-grain CVD diamond on silicon. Results indicate that in ultrahigh vacuum the ion-beam-deposited DLC films on fine-grain CVD diamond (similar to the ion-implanted CVD diamond) greatly decrease both the friction and wear of fine-grain CVD diamond films and provide solid lubrication. In dry nitrogen and in humid air, ion-beam-deposited DLC films on fine-grain CVD diamond films also had a low steady-state coefficient of friction and a low wear rate. These tribological performance benefits, coupled with a wider range of coating thicknesses, led to longer endurance life and improved wear resistance for the DLC deposited on fine-grain CVD diamond in comparison to the ion-implanted diamond films. Thus, DLC deposited on fine-grain CVD diamond films can be an effective wear-resistant, lubricating coating regardless of environment.

  17. In vivo evaluation of carbon-11-labelled non-sarcosine-based glycine transporter 1 inhibitors in mice and conscious monkeys

    Energy Technology Data Exchange (ETDEWEB)

    Toyohara, Jun [Division of Clinical Neuroscience, Chiba University Center for Forensic Mental Health, Chiba, Japan 260-8670 (Japan); Positron Medical Center, Tokyo Metropolitan Institute of Gerontology, Tokyo, Japan 173-0022 (Japan); Ishiwata, Kiichi; Sakata, Muneyuki [Positron Medical Center, Tokyo Metropolitan Institute of Gerontology, Tokyo, Japan 173-0022 (Japan); Wu, Jin [Division of Clinical Neuroscience, Chiba University Center for Forensic Mental Health, Chiba, Japan 260-8670 (Japan); Nishiyama, Shingo; Tsukada, Hideo [Central Research Laboratory, Hamamatsu Photonics K.K., Shizuoka, Japan 434-8601 (Japan); Hashimoto, Kenji, E-mail: hashimoto@faculty.chiba-u.j [Division of Clinical Neuroscience, Chiba University Center for Forensic Mental Health, Chiba, Japan 260-8670 (Japan)

    2011-05-15

    Introduction: Glycine transporter 1 (GlyT-1) is an attractive target in positron emission tomography (PET) studies. Here, we report the in vivo evaluation of three carbon-11-labelled non-sarcosine-type GlyT-1 inhibitors - [{sup 11}C]SA1, [{sup 11}C]SA2 and [{sup 11}C]SA3 - as novel PET tracers for GlyT-1. Methods: The regional brain distributions of the three compounds in mice were studied at baseline and under receptor-blockade conditions with co-injection of carrier loading or pretreatment with an excess of selective GlyT-1 inhibitors (ALX-5407 and SSR504734). Metabolic stability was investigated by radio high-performance liquid chromatography. Dynamic PET scans in conscious monkeys were performed with/without selective GlyT-1 inhibitors. Results: The IC{sub 50} values of SA1, SA2 and SA3 were 9.0, 6400 and 39.7 nM, respectively. The regional brain uptakes of [{sup 11}C]SA1 and [{sup 11}C]SA3 in mice were heterogeneous and consistent with the known distribution of GlyT-1. [{sup 11}C]SA2 showed low and homogeneous uptake in the brain. Most radioactivity in the brain was detected in unchanged form, although peripherally these compounds were degraded. Carrier loading decreased the uptake of [{sup 11}C]SA1 in GlyT-1-rich regions. However, similar reductions were not observed with [{sup 11}C]SA3. Pretreatment with ALX-5407 decreased the uptake of [{sup 11}C]SA1 in GlyT-1-rich regions. In the monkey at baseline, regional brain uptake of [{sup 11}C]SA1 was heterogeneous and consistent with the known GlyT-1 distribution. Pretreatment with selective GlyT-1 inhibitors significantly decreased the distribution volume ratio of [{sup 11}C] SA1 in GlyT-1-rich regions. Conclusions: [{sup 11}C]SA1 has the most suitable profile among the three carbon-11-labelled GlyT-1 inhibitors. Lead optimization of [{sup 11}C]SA1 structure will be required to achieve in vivo selective GlyT-1 imaging.

  18. Synthesis and biological evaluation of carbon-11 and fluorine-18 labeled tracers for in vivo visualization of PDE10A

    International Nuclear Information System (INIS)

    Introduction: In vivo visualization of PDE10A using PET provides a tool to evaluate the role of PDE10A in various neuropsychiatric diseases and can also be useful in the clinical evaluation of PDE10A inhibitor drug candidates. We evaluated several carbon-11 and fluorine-18 labeled PDE10A inhibitors as potential PDE10A PET radioligands. Materials and Methods: [11C]MP10, [11C]JNJ42071965 and four other tracers were developed. Their biodistribution was evaluated in rats. Rat plasma and brain radiometabolites were quantified. Baseline microPET imaging was performed in normal rats and PDE10A knockout (KO) and wild-type (WT) mice. Blocking and displacement studies were conducted. The selectivity of the tracer binding was further studied in an ex vivo autoradiography experiment in PDE10A KO and WT mice. Results: Biodistribution showed brain uptake for all tracers in the striatum and wash-out from the cerebellum. [11C]1 (11C-MP10) had the highest specific uptake index (striatum (S) vs. cerebellum (C) ratios (S/C)-1) at 60 min (7.4). [11C]5 ([11C]JNJ42071965) had a high index at the early time points (1.0 and 3.7 at 2 and 30 min p.i., respectively). The affinity of [11C]4, [18 F]3 and [18 F]6 was too low to visualize PDE10A using microPET. [11C] 2 showed a specific binding, while kinetics of [11C]1 were too slow. [11C]5 reached equilibrium after 10 min (uptake index = 1.2). Blocking and displacement experiments in rats and baseline imaging in PDE10A KO mice showed specific and reversible binding of [11C]5 to PDE10A. Conclusions: We successfully radiolabeled and evaluated six radiotracers for their potential to visualize PDE10A in vivo. While [11C]1 had the highest striatal specific uptake index, its slow kinetics likely compromise clinical use of this tracer. [11C]5 has a relatively high striatum-to-background ratio and fast kinetic profile, which makes it a valuable carbon-11 alternative

  19. Experimental study of the water-to-air stopping power ratio of monoenergetic carbon ion beams for particle therapy

    Science.gov (United States)

    Sánchez-Parcerisa, D.; Gemmel, A.; Jäkel, O.; Parodi, K.; Rietzel, E.

    2012-06-01

    Reference dosimetry with ionization chambers requires a number of chamber-specific and beam-specific calibration factors. For carbon ion beams, IAEA report TRS-398 yields a total uncertainty of 3% in the determination of the absorbed dose to water, for which the biggest contribution arises from the water-to-air stopping power ratio (sw, air), with an uncertainty of 2%. The variation of (sw, air) along the treatment field has been studied in several Monte Carlo works presented over the last few years. Their results were, in all cases, strongly dependent on the choice of mean ionization potentials (I-values) for air and water. A smaller dependence of (sw, air) with penetration depth was observed. Since a consensus on Iw, air and Iair has not yet been reached, the validity of such studies for clinical use cannot be assessed independently. Our approach is based on a direct experimental measurement of water-equivalent thicknesses of different air gaps at different beam energies. A theoretical expression describing the variation of the stopping power ratio with kinetic energy, sw,air(E), was derived from the Bethe-Bloch formula and fit to the measured data, yielding a coherent pair of Iw and Iair values with Iair/Iw = 1.157 ± 0.023. Additionally, the data from five different beam energies were combined in an average value of sw,air = 1.132 ± 0.003 (statistical) ± 0.003 (variation over energy range), valid for monoenergetic carbon ion beams at the plateau area of the depth dose distribution. A detailed uncertainty analysis was performed on the data, in order to assess the limitations of the method, yielding an overall standard uncertainty below 1% in sw,air(E). Therefore, when properly combined with the appropriate models for the fragment spectra, our experimental work can contribute to narrow the uncertainty margins currently in use in absorbed dose to water determination for dosimetry of carbon ion beam radiotherapy.

  20. Extended high order sandwich panel theory for bending analysis of sandwich beams with carbon nanotube reinforced face sheets

    Science.gov (United States)

    Jedari Salami, S.

    2016-02-01

    Bending analysis of a sandwich beam with soft core and carbon nanotube reinforced composite (CNTRC) face sheets in the literature is presented based on Extended High order Sandwich Panel Theory (EHSAPT). Distribution of fibers through the thickness of the face sheets could be uniform or functionally graded (FG). In this theory the face sheets follow the first order shear deformation theory (FSDT). Besides, the two dimensional elasticity is used for the core. The field equations are derived via the Ritz based solution which is suitable for any essential boundary condition. The influences of boundary conditions on bending response of the sandwich panel with soft core and CNTRC face sheet are investigated. In each type of boundary condition the effect of distribution pattern of CNTRCs on many essential involved parameters of the sandwich beam with functionally graded carbon nanotube reinforced composite (FG- CNTRC) face sheets are studied in detail. Finally, experimental result have been compared with those obtained based on developed solution method. It is concluded that, the sandwich beam with X distribution figure of face sheets is the strongest with the smallest transverse displacement, and followed by the UD, O and ∧-ones, respectively.

  1. Reinforced concrete T-beams externally prestressed with unbonded carbon fiber-reinforced polymer tendons

    DEFF Research Database (Denmark)

    Bennitz, Anders; Nilimaa, Jonny; Ravn, Dorthe Lund;

    2012-01-01

    force, and the presence of a deviator were investigated. The results were compared to those observed with analogous beams prestressed with steel tendons, common beam theory, and predictions made using an analytical model adapted from the literature. It was found that steel and CFRP tendons had very...

  2. Ion-beam and microwave-stimulated functionalization and derivatization of carbon nanotubes

    Science.gov (United States)

    Makala, Raghuveer S.

    Derivatizing carbon nanotubes (CNTs) with other low-dimensional nanostructures is of widespread interest for creating CNT-based nanocomposites and devices. Conventional routes based on wet-chemical oxidation or hydrophobic adsorption do not allow premeditated control over the location or spatial extent of functionalization. Moreover, aggressive oxidative treatments and agitation in corrosive environments lead to CNT shortening, damage, and incorporation of excess impurity concentrations. Thus, it is imperative to explore and develop alternative functionalization methods to overcome these shortcomings. The work presented in this thesis outlines two such methodologies: one based on focused ion irradiation for siteselective functionalization and the other that employs microwave-stimulation for mild, yet rapid and homogenous CNT functionalization. The utility of 10 and 30 kcV Ga+ focused ion beams (FIB) to thin, slice, weld, and alter the structure and composition at precise locations along the CNT axis is presented. This strategy of harnessing ion-beam-induced defect generation and doping is attractive for modulating chemical and electrical properties along the CNT length, and fabricate CNT-based heterostructures and networks. A novel approach that utilizes focused ion irradiation to site-selectively derivatize preselected segments of CNTs with controlled micro-/nano-scale lateral spatial resolution is demonstrated. Irradiation followed by air-exposure results in functionalized CNT segments ranging from the nanoscopic to the macroscopic scale. The functional moieties are utilized to site-selectively anchor Au nanoparticles, fluorescent nanospheres, an amino acid---lysine, a charge-transfer metalloprotein---azurin, and a photoactive protein---bacteriorhodopsin by means of electrostatic or covalent interactions. This approach is versatile and can be extended to obtaining other molecular moieties and derivatives opening up possibilities for building new types of nano

  3. Study on reinforced concrete beams strengthened using shape memory alloy wires in combination with carbon-fiber-reinforced polymer plates

    Science.gov (United States)

    Li, Hui; Liu, Zhi-qiang; Ou, Jin-ping

    2007-12-01

    It has been proven that carbon-fiber-reinforced polymer (CFRP) sheets or plates are capable of improving the strength of reinforced concrete (RC) structures. However, residual deformation of RC structures in service reduces the effect of CFRP strengthening. SMA can be applied to potentially decrease residual deformation and even close concrete cracks because of its recovery forces imposed on the concrete when heated. Therefore, a method of a RC structure strengthened by CFRP plates in combination with SMA wires is proposed in this paper. The strengthening effect of this method is investigated through experiments and numerical study based on the nonlinear finite element software ABAQUS in simple RC beams. Parametric analysis and assessment of damage by defining a damage index are carried out. The results indicate that recovery forces of SMA wires can decrease deflections and even close cracks in the concrete. The recovery rate of deflection of the beam increases with increasing the ratio of SMA wires. The specimen strengthened with CFRP plates has a relatively large stiffness and smaller damage index value when the residual deformation of the beam is first reduced by activation of the SMA wires. The effectiveness of this strengthening method for RC beams is verified by experimental and numerical results.

  4. Proton, Helium and Carbon Radiation Beam Targeting Reactive Oxygen, Nitrogen and Halogenated Species in TRIM-SRIM Model

    International Nuclear Information System (INIS)

    Nowadays proton beam radiation therapy is considered in few centers for management of malignancies. This study is aimed to explore the effect of proton, helium or carbon irradiation on free radicals. This study was conducted in department of Physiology/Medical physics, College of Medicine, Al-Mustansiriya University in Baghdad, Iraq during October 2009. TRIM-SRIM software version 1998 and2003 were used for computed Bragg peak and for calculated the effect of proton, helium and carbon ions against free radicals related to oxygen, nitrogen and halogen species. The lowest stopping power near Bragg's peak of proton targeting free radicals was against superoxide anion and its curve (the stopping power against energy) was shifted down while that of peroxynitrite(ONOO-) was shifted up. The stopping powers of helium targeting all studied free radicals were lower than corresponding proton irradiation but it required higher energy. Lower stopping power of carbon irradiation targeted hydroxyl(OH-) and halogenated radicals than the other reactive species were observed. It concludes that such from of external beam irradiation is associated with direct scavenging effect on free radicals of whatever sources.

  5. Effects of E-Beam Irradiation on the Chemical, Physical, and Electrochemical Properties of Activated Carbons for Electric Double-Layer Capacitors

    OpenAIRE

    Min-Jung Jung; Mi-Seon Park; Young-Seak Lee

    2015-01-01

    Activated carbons (ACs) were modified via e-beam irradiation at various doses for use as an electrode material in electric double-layer capacitors (EDLCs). The chemical compositions of the AC surfaces were largely unchanged by the e-beam irradiation. The ACs treated with the e-beam at radiation doses of 200 kGy exhibited higher nanocrystallinity than the untreated ACs. The specific surface areas and pore volumes of the e-beam irradiated ACs were also higher than those of the untreated ACs. Th...

  6. Formation of nanoscale carbon structures in the surface layer of metals under the impact of high intensity ion beam

    Energy Technology Data Exchange (ETDEWEB)

    Remnev, G.E., E-mail: remnev@hvd.tpu.ru [High-Voltage Research Institute at Tomsk Polytechnic University, 2a Lenin Ave., Tomsk 634028 (Russian Federation); Uglov, V.V., E-mail: uglov@bsu.by [Belarusian State University, 4 Nezavisimosti Ave., Minsk 220030 (Belarus); Shymanski, V.I. [Belarusian State University, 4 Nezavisimosti Ave., Minsk 220030 (Belarus); Pavlov, S.K. [High-Voltage Research Institute at Tomsk Polytechnic University, 2a Lenin Ave., Tomsk 634028 (Russian Federation); Kuleshov, A.K. [Belarusian State University, 4 Nezavisimosti Ave., Minsk 220030 (Belarus)

    2014-08-15

    Highlights: • Carbide phases in metals were formed by high-intense pulsed ion beam (HPIB) impact. • Tungsten and titanium carbides are characterized by nanoscale dimensions. • Carbides formation in surface layer provides its hardening. - Abstract: This work represents the results of phase composition and the mechanical properties of tungsten and titanium after high-intensity pulsed ion beam (HPIB) treatment. It was shown that nanoscale carbide particles are formed under the HPIB influence in the surface layers of metals. Raising the pulse number results in increase of volume fraction of the carbide phases. The microhardness is 1.5–2 times more than the initial value and wear resistance of the metals improves in response to alloying of tungsten and titanium with carbon atoms accompanied by the formation of carbides.

  7. Non-Detection of HC11N toward TMC-1: Constraining the Chemistry of Large Carbon-Chain Molecules

    Science.gov (United States)

    Loomis, Ryan A.; Shingledecker, Christopher N.; Langston, Glen; McGuire, Brett A.; Dollhopf, Niklaus M.; Burkhardt, Andrew M.; Corby, Joanna; Booth, Shawn T.; Carroll, P. Brandon; Turner, Barry; Remijan, Anthony J.

    2016-09-01

    Bell et al. (1997) reported the first detection of the cyanopolyyne HC11N toward the cold dark cloud TMC-1; no subsequent detections have been reported toward any source. Additional observations of cyanopolyynes and other carbon-chain molecules toward TMC-1 have shown a log-linear trend between molecule size and column density, and in an effort to further explore the underlying chemical processes driving this trend, we have analyzed GBT observations of HC9N and HC11N toward TMC-1. Although we find an HC9N column density consistent with previous values, HC11N is not detected and we derive an upper limit column density significantly below that reported in Bell et al. (1997). Using a state-of-the-art chemical model, we have investigated possible explanations of non-linearity in the column density trend. Despite updating the chemical model to better account for ion-dipole interactions, we are not able to explain the non-detection of HC11N, and we interpret this as evidence of previously unknown carbon-chain chemistry. We propose that cyclization reactions may be responsible for the depleted HC11N abundance, and that products of these cyclization reactions should be investigated as candidate interstellar molecules.

  8. Synthesis and carbon-11 labeling of (R)- and (S)-thionisoxetine, norepinephrine reuptake inhibitors, potential radioligands for positron emission tomography

    International Nuclear Information System (INIS)

    Standards and des-methyl precursors of (R)- and (S)-thionisoxetine, potent and selective norepinephrine reuptake inhibitors, were synthesized and radiolabeled with carbon-11. Both enantiomers of the N-methyl-3-(2-thiomethylphenoxy)-3-phenylpropanamine and the 3-(2-thiomethylphenoxy)-3-phenylpropylamine were obtained via multi-step syntheses, while the radiosyntheses were carried out using [11C]CH3I. The radiochemical yields were 26%, decay corrected and the specific radioactivity ranging from 2 to 3 Ci/μmol. The HPLC analyses were performed using a chiral column: during the radiolabeling, no racemization occurred and the isomers were synthesized with high enantiomeric purity

  9. Generation of oxygen, carbon and metallic ion beams by a compact microwave source

    International Nuclear Information System (INIS)

    A small microwave ion source fabricated from a quartz tube and enclosed externally by a cavity has been operated with different geometries and for various gases in a cw mode. This source has been used to generate oxygen ion beams with energy as low as 5.5 eV. Beam energy spread has been measured to be less than 1 eV. By installing different metal plates on the front extraction electrode, metallic ion beams such as (Be, Cu, Al, etc.) can be produced

  10. Phase space generation for proton and carbon ion beams for external users’ applications at the Heidelberg Ion Therapy Center

    Directory of Open Access Journals (Sweden)

    Thomas eTessonnier

    2016-01-01

    Full Text Available In the field of radiation therapy, accurate and robust dose calculation is required. For this purpose, precise modeling of the irradiation system and reliable computational platforms are needed. At the Heidelberg Ion Therapy Center (HIT, the beamline has been already modeled in the FLUKA Monte Carlo code. However, this model was kept confidential for disclosure reasons and was not available for any external team. The main goal of this study was to create efficiently phase space (PS files for proton and carbon ion beams, for all energies and foci available at HIT. PS are representing the characteristics of each particle recorded (charge, mass, energy, coordinates, direction cosines, generation at a certain position along the beam path. In order to achieve this goal, keeping a reasonable data size but maintaining the requested accuracy for the calculation, we developed a new approach of beam PS generation with the Monte-Carlo code FLUKA. The generated PS were obtained using an infinitely narrow beam and recording the desired quantities after the last element of the beamline, with a discrimination of primaries or secondaries. In this way, a unique PS can be used for each energy to accommodate the different foci by combining the narrow-beam scenario with a random sampling of its theoretical Gaussian beam in vacuum. PS can also reproduce the different patterns from the delivery system, when properly combined with the beam scanning information. MC simulations using PS have been compared to simulations including the full beamline geometry and have been found in very good agreement for several cases (depth dose distributions, lateral dose profiles, with relative dose differences below 0.5%. This approach has also been compared with measured data of ion beams with different energies and foci, resulting in a very satisfactory agreement. Hence, the proposed approach was able to fulfill the different requirements and has demonstrated its capability for

  11. Measurement of the analyzing power for proton-carbon elastic scattering in the CNI region with a 22 GeV/c polarized proton beam

    International Nuclear Information System (INIS)

    We have carried out the experiment BNL-AGS E950 to measure the analyzing power for proton-carbon elastic scattering in the Coulomb-Nuclear Interference (CNI) region with a 22 GeV/c polarized proton beam. Recoil carbons from 300 keV to a few MeV in the CNI region, were detected inside the AGS ring to identify proton-carbon elastic scattering. The preliminary results of the analyzing power measurement are presented

  12. Ion beam induced charge collection (IBICC) from integrated circuit test structures using a 10 MeV carbon microbeam

    Energy Technology Data Exchange (ETDEWEB)

    Guo, B.N.; Bouanani, M.E.; Duggan, J.L.; McDaniel, F.D. [Ion Beam Modification and Analysis Laboratory, Department of Physics, University of North Texas, Denton, Texas 76203 (United States); Doyle, B.L.; Walsh, D.S. [Ion Beam Materials Research Laboratory, Sandia National Laboratories, MS 1056, PO Box 5800, Albuquerque, New Mexico 87185 (United States)] Aton, T.J. [Silicon Technology Development, Texas Instruments Inc., PO Box 650311, MS 3704, Dallas, Texas 75265 (United States)

    1999-06-01

    As feature sizes of Integrated Circuits (ICs) continue to shrink, the sensitivity of these devices, particularly SRAMs and DRAMs, to natural radiation is increasing. In this paper, the Ion Beam Induced Charge Collection (IBICC) technique is utilized to simulate neutron-induced Si recoil effects in ICs. The IBICC measurements, conducted at the Sandia National Laboratories, employed a 10 MeV carbon microbeam with 1{mu}m diameter spot to scan test structures on specifically designed ICs. With the aid of IC layout information, an analysis of the charge collection efficiency from different test areas is presented. {copyright} {ital 1999 American Institute of Physics.}

  13. Measurement of neutral current coherent neutral pion production on carbon in a few-GeV neutrino beam

    OpenAIRE

    Kurimoto, Y; Alcaraz-Aunion, J. L.; Brice, S J; Bugel, L.; Catala-Perez, J.; Cheng, G.; Conrad, J.M.; Djurcic, Z.; Dore, U.; Finley, D. A.; Franke, A. J.; C. Giganti; Gomez-Cadenas, J. J.; Guzowski, P.; Hanson, A.

    2010-01-01

    The SciBooNE Collaboration reports a measurement of neutral current coherent neutral pion production on carbon by a muon neutrino beam with average energy 0.8 GeV. The separation of coherent from inclusive neutral pion production has been improved by detecting recoil protons from resonant neutral pion production. We measure the ratio of the neutral current coherent neutral pion production to total charged current cross sections to be (1.16 +/- 0.24) x 10-2. The ratio of charged current cohere...

  14. Different effects of carbon ion beams and X-rays on clonogenic survival and DNA repair in human pancreatic cancer stem-like cells

    International Nuclear Information System (INIS)

    Purpose: The effects of a carbon ion beam and X-rays on human pancreatic cancer stem-like cells were examined from the point of view of clonogenic survival and DNA repair. Materials and methods: Human pancreatic cancer stem-like cells were treated with and without carbon ion and X-ray irradiation, and then colony, spheroid and tumor formation assays as well as γH2AX foci formation assay were performed. Results: The relative biological effectiveness (RBE) values of a carbon ion beam relative to X-ray for the MIA PaCa-2 and BxPc-3 cells at the D10 values were 1.85–2.10. The ability for colony, spheroid formation, and tumorigenicity from cancer stem-like CD44+/CD24+ cells is significantly higher than that from non-cancer stem-like CD44−/CD24−cells. FACS data showed that CD44+/CD24+ cells were more highly enriched after X-rays compared to carbon ion irradiation at isoeffective doses. The RBE values for the carbon ion beam relative to X-ray at the D10 levels for CD44+/CD24+ cells were 2.0–2.19. The number of γH2AX foci in CD44−/CD24− cells was higher than that of CD44+/CD24+ cells after irradiation with either X-ray or carbon ion beam. The number of γH2AX foci in CD44+/CD24+ cells was almost the same in the early time, but it persists significantly longer in carbon ion beam irradiated cells compared to X-rays. Conclusions: Carbon ion beam has superior potential to kill pancreatic cancer stem cell-like cells, and prolonged induction of DNA damage might be one of the pivotal mechanisms of its high radiobiological effects compared to X-rays.

  15. Vacuum Electron-Beam Evaporation of Fe Nanocrystals on Si3N4 Buffer Layer for carbon Nanotube Growth

    Institute of Scientific and Technical Information of China (English)

    万青; 王太宏; 林成鲁

    2003-01-01

    Vacuum electron-beam evaporated iron nanocrystal is used for the growth of carbon nanotubes. Atomic force microscopy and Raman scattering studies reveal the formation of beta-iron silicide islands on bare silicon substrate after annealing at 700°C in N2 ambient. In order to eliminate the influence of iron-silicon interaction, Si3N4 buffer layer with the thickness of 80 nm is used. This technical route prevents effectively the formation of iron silicide and improves the quality of the iron nanocrystals. Using these iron nanocrystals with high density (about 7 × 1010/cm2) as catalyst, high-density multiwall carbon nanotubes are synthesized on Si3N4/Si substrate.

  16. Formation of Carbonized Polystyrene Sphere/hemisphere Shell Arrays by Ion Beam Irradiation and Subsequent Annealing or Chloroform Treatment

    Science.gov (United States)

    Song, Xianyin; Dai, Zhigao; Xiao, Xiangheng; Li, Wenqing; Zheng, Xudong; Shang, Xunzhong; Zhang, Xiaolei; Cai, Guangxu; Wu, Wei; Meng, Fanli; Jiang, Changzhong

    2015-01-01

    Heat-resistant two-dimensional (2D) sphere/hemisphere shell array is significant for the fabrication of novel nanostructures. Here large-area, well-ordered arrays of carbonized polystyrene (PS) hollow sphere/hemisphere with controlled size and morphology are prepared by combining the nanosphere self-assembly, kV Ag ion beam modification, and subsequent annealing or chloroform treatment. Potential mechanisms for the formation and evolution of the heat-resistant carbonized PS spherical shell with increasing ion fluence and energy are discussed. Combined with noble metal or semiconductor, these modified PS sphere arrays should open up new possibilities for high-performance nanoscale optical sensors or photoelectric devices. PMID:26640125

  17. Rapid synthesis and purification of carbon-11 labelled DOPA: a potential agent for brain studies

    International Nuclear Information System (INIS)

    A rapid method for preparation and purification of β-(3,4-dihydroxyphenyl)-D,L-α-alanine-1-11C(11C-DOPA), using 11CO2 as the radioactive precursor is described. Carboxylation of an α-lithioisocyanide, containing protected hydroxylic groups, was followed by a three-step hydrolysis of the intermediate αioscyano carboxylic acid. Preliminary experiments in rats indicate that the compound is preferentially decarboxylated in brain areas rich in dopamine containing neurons. (author)

  18. Development of rapid multistep carbon-11 radiosynthesis of the myeloperoxidase inhibitor AZD3241 to assess brain exposure by PET microdosing

    International Nuclear Information System (INIS)

    Introduction: The myeloperoxidase inhibitor AZD3241 has been selected as a candidate drug currently being developed to delay progression in patients with neurodegenerative brain disorders. Part of the decision tree for translation of AZD3241 into clinical studies included the need for assessment of brain exposure in non-human primates by PET microdosing. For that purpose a rapid multistep method for 11C-labeling of AZD3241 was developed. Methods: AZD3241 was labeled in the thio-carbonyl position starting from [11C]potassium cyanide in a 4-step procedure using microwave assisted heating. In the first step [11C]potassium cyanide was converted to [11C]potassium thiocyanate followed by reaction with benzoyl chloride to yield benzoyl [11C]isothiocyanate. The benzoyl [11C]isothiocyanate was subsequently reacted with the precursor ethyl 3-(2-isopropoxyethylamino)-1H-pyrrole-2-carboxylate and the formed intermediate underwent a base catalyzed cyclization to obtain [11C]AZD3241 in the final step. To assess [11C]AZD3241 brain exposure PET measurements were performed in three cynomolgus monkeys. Results: [11C]AZD3241 was produced in good and reproducible radiochemical yield 710 ± 294 MBq (mean ± SD, n = 7). Total time of synthesis was 60 min from end of bombardment. The specific radioactivity was 9 ± 4 GBq/μmol and the radiochemical purity was > 98%. Following iv administration of [11C]AZD3241 there was a rapid presence of radioactivity in brain in each of the three monkeys. The distribution of [11C]AZD3241 to brain was fast and a Cmax of 1.9 to 2.6% of the injected radioactivity was observed within 1.5 min. [11C]AZD3241 was homogeneously distributed in brain. Conclusion: The MPO inhibitor AZD3241 was successfully labeled with carbon-11 in a challenging 4-step procedure in good radiochemical yield allowing PET microdosing studies in cynomolgus monkey. [11C]AZD3241 rapidly entered brain and confirmed adequate brain exposure to support translation of AZD3241 to phase 2a

  19. Stable isotopic compositions of elemental carbon in PM1.1 in north suburb of Nanjing Region, China

    Science.gov (United States)

    Guo, Zhaobing; Jiang, Wenjuan; Chen, Shanli; Sun, Deling; Shi, Lei; Zeng, Gang; Rui, Maoling

    2016-02-01

    Stable isotopic compositions (δ13C) of elemental carbon (EC) in PM1.1 in north suburb of Nanjing region were determined in order to quantitatively evaluate the carbon sources of atmospheric fine particles during different seasons. Besides, δ13C values from potential sources such as coal combustion, vehicle exhaust, biomass burning, and dust were synchronously measured. The results showed that the average δ13C values of EC in PM1.1 in winter and summer were - 23.89 ± 1.6‰ and - 24.76 ± 0.9‰, respectively. Comparing with δ13C values from potential sources, we concluded that the main sources of EC in PM1.1 were from the emission of coal combustion and vehicle exhaust. The higher δ13C values in winter than those in summer were chiefly attributed to the more coal consumption. Combining with the concentrations of SO42 - and K+ in PM1.1, the high δ13C values of EC on 24 December and 27 December 2013 were ascribed to extra input of corn straw burning in addition to coal combustion and vehicle exhaust.

  20. Cationic concentration effects on electron beam cured of carbon-epoxy composites

    International Nuclear Information System (INIS)

    Electron beam (e-beam) curing is a technology that offers advantages over the thermal curing process, that usually requires high temperature and are time-consuming. E-beam curing is faster and occurs at low temperatures that help reduce residual mechanical stresses in a thermoset composite. The aim of the present study is to analyze the effects of cationic initiator (diaryliodonium hexafluoroantimonate) ranged from 1 to 3 wt% in DGEBA (diglycidyl ether of bisphenol A) epoxy resin when cured by a 1.5 MeV electron beam. The specimens were cured to a total dose of 200.4 kGy for 40 min. Analyses by dynamic mechanical thermal analysis (DMTA) and differential scanning calorimetry (DSC) show that the e-beam irradiated samples with 2 wt% cationic initiator were 96% cured obtained a glass transition temperature (tan δ) of 167 deg. C. The same epoxy resin, thermally cured for 16 h with an anhydride hardener, reached a Tg (tan δ) of 136 deg. C. So, the irradiated sample had its Tg increased approximately 20% and the curing process was much less time consuming.

  1. Cationic concentration effects on electron beam cured of carbon-epoxy composites

    Energy Technology Data Exchange (ETDEWEB)

    Nishitsuji, D.A., E-mail: delmo_amari@yahoo.com.b [Brazilian Navy Technological Center, Sao Paulo (Brazil); Marinucci, G. [Brazilian Navy Technological Center, Sao Paulo (Brazil); Energetic and Nuclear Research Institute-IPEN-CNEN/SP, Av. Prof. Lineu Prestes, 2242-Cidade Universitaria, 05508-000 Sao Paulo/SP (Brazil); Evora, M.C. [Institute of Advanced Studies/CTA, Sao Jose dos Campos/SP (Brazil); Silva, L.G.A. [Energetic and Nuclear Research Institute-IPEN-CNEN/SP, Av. Prof. Lineu Prestes, 2242-Cidade Universitaria, 05508-000 Sao Paulo/SP (Brazil)

    2010-03-15

    Electron beam (e-beam) curing is a technology that offers advantages over the thermal curing process, that usually requires high temperature and are time-consuming. E-beam curing is faster and occurs at low temperatures that help reduce residual mechanical stresses in a thermoset composite. The aim of the present study is to analyze the effects of cationic initiator (diaryliodonium hexafluoroantimonate) ranged from 1 to 3 wt% in DGEBA (diglycidyl ether of bisphenol A) epoxy resin when cured by a 1.5 MeV electron beam. The specimens were cured to a total dose of 200.4 kGy for 40 min. Analyses by dynamic mechanical thermal analysis (DMTA) and differential scanning calorimetry (DSC) show that the e-beam irradiated samples with 2 wt% cationic initiator were 96% cured obtained a glass transition temperature (tan delta) of 167 deg. C. The same epoxy resin, thermally cured for 16 h with an anhydride hardener, reached a T{sub g} (tan delta) of 136 deg. C. So, the irradiated sample had its T{sub g} increased approximately 20% and the curing process was much less time consuming.

  2. Chemical investigations of isotope separation on line target units for carbon and nitrogen beams

    CERN Document Server

    Franberg, H; Gäggeler, H W; Köster, U

    2006-01-01

    Radioactive ion beams (RIBs) are of significant interest in a number of applications. Isotope separation on line (ISOL) facilities provide RIB with high beam intensities and good beam quality. An atom that is produced within the ISOL target will first diffuse out from the target material. During the effusion towards the transfer line and into the ion source the many contacts with the surrounding surfaces may cause unacceptable delays in the transport and, hence, losses of the shorter-lived isotopes. We performed systematic chemical investigations of adsorption in a temperature and concentration regime relevant for ISOL targets and ion source units, with regard to CO/sub x/ and NOmaterials are potential construction materials for the above-mentioned areas. Off-line and on-line tests have been performed using a gas thermochromatography setup with radioactive tracers. The experiments were performed at the production of tracers for atmospheric chemistry (PROTRAC) facility at the Paul Schener Institute in Villigen...

  3. Synthesis and in vivo brain distribution of carbon-11-labeled {delta}-opioid receptor agonists

    Energy Technology Data Exchange (ETDEWEB)

    Pichika, Rama, E-mail: rpichika@ucsd.ed [Department of Radiology, University of California, San Diego, CA (United States); Jewett, Douglas M.; Sherman, Philip S. [Division of Nuclear Medicine, Department of Radiology, University of Michigan Medical School, Ann Arbor, MI 48109 (United States); Traynor, John R. [Department of Pharmacology, University of Michigan Medical School, Ann Arbor, MI 48109 (United States); Husbands, Stephen M. [Department of Pharmacy and Pharmacology, University of Bath, Bath (United Kingdom); Woods, James H. [Department of Pharmacology, University of Michigan Medical School, Ann Arbor, MI 48109 (United States); Kilbourn, Michael R. [Division of Nuclear Medicine, Department of Radiology, University of Michigan Medical School, Ann Arbor, MI 48109 (United States)

    2010-11-15

    Three new radiolabeled compounds, [{sup 11}C]SNC80 ((+)-4-[({alpha}R)-{alpha}-{l_brace}(2S,5R)-4-allyl-2,5-dimethyl-1-piperazinyl{r_brace}-3-[{sup 11}C] methoxybenzyl-N,N-diethylbenzamide), N,N-diethyl-4-[3-methoxyphenyl-1-[{sup 11}C]methylpiperidin-4-ylidenemethyl) benzamide and N,N-diethyl-4-[(1-[{sup 11}C]methylpiperidin-4-ylidene)phenylmethyl]benzamide, were prepared as potential in vivo radiotracers for the {delta}-opioid receptor. Each compound was synthesized by alkylation of the appropriate desmethyl compounds using [{sup 11}C]methyl triflate. In vivo biodistribution studies in mice showed very low initial brain uptake of all three compounds and no regional specific binding for [{sup 11}C]SNC80. A monkey positron emission tomography study of [{sup 11}C]SNC80 confirmed low brain permeability and uniform regional distribution of this class of opioid agonists in a higher species. Opioid receptor ligands of this structural class are thus unlikely to succeed as in vivo radiotracers, likely due to efficient exclusion from the brain by the P-glycoprotein efflux transporter.

  4. Geant4 simulation for a study of a possible use of carbon ion pencil beams for the treatment of ocular melanomas with the active scanning system at CNAO

    Science.gov (United States)

    Farina, E.; Piersimoni, P.; Riccardi, C.; Rimoldi, A.; Tamborini, A.; Ciocca, M.

    2015-12-01

    The aim of this work was to study a possible use of carbon ion pencil beams (delivered with active scanning modality) for the treatment of ocular melanomas at the Centro Nazionale di Adroterapia Oncologica (CNAO). The promising aspect of carbon ions radiotherapy for the treatment of this disease lies in its superior relative radio-biological effectiveness (RBE). The Monte Carlo (MC) Geant4 10.00 toolkit was used to simulate the complete CNAO extraction beamline, with the active and passive components along it. A human eye modeled detector, including a realistic target tumor volume, was used as target. Cross check with previous studies at CNAO using protons allowed comparisons on possible benefits on using such a technique with respect to proton beams. Experimental data on proton and carbon ion beams transverse distributions were used to validate the simulation.

  5. MODIFICATION OF CARBON STEEL BY LASER SURFACE MELTING: PART II: EFFECT OF LASER BEAM POWER ON MICROSTRUCTURAL FEATURES AND SURFACE HARDNESS

    OpenAIRE

    Hashem F. El-Labban; Abdelaziz, M.; Essam R.I. Mahmoud

    2013-01-01

    The surface hardness has an important effect on the wear resistance of different materials. The present study aims to improve the surface hardness of carbon steel through the application of laser surface melting with suitable conditions. The laser beam power and travelling speed are the main factors that affect the properties of the treated zone. In this study, three different conditions of laser beam power (1800, 1500 and 1200 W) at fixed travelling speed of 1000 mm min-1 were chosen to stud...

  6. Carbon-11-labeled amino acids for the rectilinear and positron tomographic imaging of the human pancreas

    Energy Technology Data Exchange (ETDEWEB)

    Huebner, K.F.; Andrews, G.A.; Buonocore, E.; Hayes, R.L.; Washburn, L.C.; Collmann, I.R.; Gibbs, W.D.

    1979-06-01

    Modification of the Buecherer-Strecker amino acid synthesis facilitated the production of DL-(/sup 11/C)tryptophan and DL-(/sup 11/C)valine for clinical trials in patients with proven or suspected pancreatic disease. Examples of rectilinear scans and tomographic images of the pancreas are presented in this initial paper. Positron computed tomography was done with the ORTEC ECAT system. Rapid localization of these C-11-labeled amino acids and fast clearance from the plasma permit almost immediate examination following i.v. injection. Illustrative images include the normal pancreas, pancreatitis, and pancreatic carcinoma. The use of positron tomography with C-11-labeled DL-tryptophan and DL-valine appears to offer a new and promising diagnostic modality for the detection and study of pancreatic diseases.

  7. Amorphous track modelling of luminescence detector efficiency in proton and carbon beams

    DEFF Research Database (Denmark)

    Greilich, Steffen; Grzanka, Leszek; Bassler, Niels;

    Introduction: The radioluminescence (RL) and optically stimulated luminescence (OSL) response of Al2O3:C crystals attached to optical fibres can be used for active and passive in-vivo dosimetry in radiotherapy treatments and clinical imaging techniques. Their use in particle beams, however, can b...

  8. One-nucleon transfer reactions induced by secondary beam of {sup 11}Be: study of the nuclear structure of the exotic nuclei {sup 11}Be and {sup 10}Li; Reactions de transfert d'un nucleon induites par un faisceau secondaire de {sup 11}Be: etude de la structure des noyaux exotiques {sup 11}Be et {sup 10}Li

    Energy Technology Data Exchange (ETDEWEB)

    Pita, S

    2000-09-01

    The structure of the neutron rich light nuclei {sup 11}Be and {sup 10}Li has been investigated by means of one nucleon transfer reactions. The experiments have been carried out at GANIL in inverse kinematics using {sup 11}Be secondary beams. The {sup 11}Be(p,d){sup 10}Be reaction bas been studied at 35.3 MeV/u. The {sup 10}Be ejectiles were analyzed by the spectrometer SPEG, and coincident deuterons were detected in the position sensitive silicon detector CHARISSA. Transfer cross sections to 0{sup +}{sub 1} and 2{sup +}{sub 1}, states in {sup 10}Be were measured up to {theta}{sub CM} = 16 deg. and compared to DWBA and CRC predictions. The effects of neutron-cure couplings on reaction form factors have been studied by solving coupled equations in the framework of a vibrational model. It is shown that the rate of core excitation {sup 10}Be{sub 2+} in the {sup 11}Be{sub gs} wave function is overestimated by a standard analysis with form factors given by the usual Separation Energy prescription. The former model predicts a rate of core excitation of 16% and leads to theoretical cross sections which are in good agreement with the experimental data. The aim of the {sup 11}Be(d,{sup 3}He){sup 10}Li experiment, realized at 37 MeV/u, was to measure the distribution of the 2s neutron strength in the unbound nucleus {sup 10}Li. The energy spectrum was deduced from the {sup 3}He energy and angle measured by the silicon strip detector array MUST. An asymmetric peak is clearly observed near the threshold, with a maximum at -S{sub n} = 130 keV. This constitutes a direct proof of the inversion of 2s and 1p{sub 1/2} shells in {sup 10}Li, which was until now a controversial question in spite of many experimental efforts. On the other band the analysis of the {sup 11}Be(d,t){sup 10}Be reaction studied in the same experiment confirms the results obtained in the {sup 11}Be(p,d){sup 10}Be reaction concerning the {sup 11}Be{sub gs} structure. This work shows the interest and feasibility

  9. Dynamics of carbon dioxide transport in a multiple sink network (GHGT-11)

    NARCIS (Netherlands)

    Veltin, J.; Belfroid, S.P.C.

    2013-01-01

    As Carbon Capture and Storage slowly gets accepted and integrated as a mean for cleaner utilization of fossil fuels, the integration of capture, transport and storage becomes a key component to properly design a CO2 network. While the boundary conditions set by the capture and storage units have bee

  10. Carbon-11 epidepride: a suitable radioligand for PET investigation of striatal and extrastriatal dopamine D2 receptors.

    Science.gov (United States)

    Langer, O; Halldin, C; Dollé, F; Swahn, C G; Olsson, H; Karlsson, P; Hall, H; Sandell, J; Lundkvist, C; Vaufrey, F; Loc'h, C; Crouzel, C; Mazière, B; Farde, L

    1999-07-01

    Epidepride [(S)-(-)-N-([1-ethyl-2-pyrrolidinyl]methyl)-5-iodo-2,3-dimethoxybenza mide] binds with a picomolar affinity (Ki = 24 pM) to the dopamine D2 receptor. Iodine-123-labeled epidepride has been used previously to study striatal and extrastriatal dopamine D2 receptors with single photon emission computed tomography (SPECT). Our aim was to label epidepride with carbon-11 for comparative quantitative studies between positron emission tomography (PET) and SPECT. Epidepride was synthesized from its bromo-analogue FLB 457 via the corresponding trimethyl-tin derivative. In an alternative synthetic pathway, the corresponding substituted benzoic acid was reacted with the optically pure aminomethylpyrrolidine-derivative. Demethylation of epidepride gave the desmethyl-derivative, which was reacted with [11C]methyl triflate. Total radiochemical yield was 40-50% within a total synthesis time of 30 min. The specific radioactivity at the end of synthesis was 37-111 GBq/micromol (1,000-3,000 Ci/mmol). Human postmortem whole-hemisphere autoradiography demonstrated dense binding in the caudate putamen, and also in extrastriatal areas such as the thalamus and the neocortex. The binding was inhibited by unlabeled raclopride. PET studies in a cynomolgus monkey demonstrated high uptake in the striatum and in several extrastriatal regions. At 90 min after injection, uptake in the striatum, thalamus and neocortex was about 11, 4, and 2 times higher than in the cerebellum, respectively. Pretreatment experiment with unlabeled raclopride (1 mg/kg) inhibited 50-70% of [11C]epidepride binding. The fraction of unchanged [11C]epidepride in monkey plasma determined by a gradient high performance liquid chromatography (HPLC) method was about 30% of the total radioactivity at 30 min after injection of [11C]epidepride. The availability of [11C]epidepride allows the PET-verification of the data obtained from quantitation studies with SPECT. PMID:10473189

  11. Carbon-11 epidepride: a suitable radioligand for PET investigation of striatal and extrastriatal dopamine D2 receptors

    International Nuclear Information System (INIS)

    Epidepride {(S)-(-)-N-([1-ethyl-2-pyrrolidinyl]methyl)-5-iodo-2,3-dimethoxybenzamide} binds with a picomolar affinity (Ki=24 pM) to the dopamine D2 receptor. Iodine-123-labeled epidepride has been used previously to study striatal and extrastriatal dopamine D2 receptors with single photon emission computed tomography (SPECT). Our aim was to label epidepride with carbon-11 for comparative quantitative studies between positron emission tomography (PET) and SPECT. Epidepride was synthesized from its bromo-analogue FLB 457 via the corresponding trimethyl-tin derivative. In an alternative synthetic pathway, the corresponding substituted benzoic acid was reacted with the optically pure aminomethylpyrrolidine-derivative. Demethylation of epidepride gave the desmethyl-derivative, which was reacted with [11C]methyl triflate. Total radiochemical yield was 40-50% within a total synthesis time of 30 min. The specific radioactivity at the end of synthesis was 37-111 GBq/μmol (1,000-3,000 Ci/mmol). Human postmortem whole-hemisphere autoradiography demonstrated dense binding in the caudate putamen, and also in extrastriatal areas such as the thalamus and the neocortex. The binding was inhibited by unlabeled raclopride. PET studies in a cynomolgus monkey demonstrated high uptake in the striatum and in several extrastriatal regions. At 90 min after injection, uptake in the striatum, thalamus and neocortex was about 11, 4, and 2 times higher than in the cerebellum, respectively. Pretreatment experiment with unlabeled raclopride (1 mg/kg) inhibited 50-70% of [11C]epidepride binding. The fraction of unchanged [11C]epidepride in monkey plasma determined by a gradient high performance liquid chromatography (HPLC) method was about 30% of the total radioactivity at 30 min after injection of [11C]epidepride. The availability of [11C]epidepride allows the PET-verification of the data obtained from quantitation studies with SPECT.

  12. Atomistic description of electron beam damage in nitrogen-doped graphene and single-walled carbon nanotubes.

    Science.gov (United States)

    Susi, Toma; Kotakoski, Jani; Arenal, Raul; Kurasch, Simon; Jiang, Hua; Skakalova, Viera; Stephan, Odile; Krasheninnikov, Arkady V; Kauppinen, Esko I; Kaiser, Ute; Meyer, Jannik C

    2012-10-23

    By combining ab initio simulations with state-of-the-art electron microscopy and electron energy loss spectroscopy, we study the mechanism of electron beam damage in nitrogen-doped graphene and carbon nanotubes. Our results show that the incorporation of nitrogen atoms results in noticeable knock-on damage in these structures already at an acceleration voltage of 80 kV, at which essentially no damage is created in pristine structures at corresponding doses. Contrary to an early estimate predicting rapid destruction via sputtering of the nitrogen atoms, in the case of substitutional doping, damage is initiated by displacement of carbon atoms neighboring the nitrogen dopant, leading to the conversion of substitutional dopant sites into pyridinic ones. Although such events are relatively rare at 80 kV, they become significant at higher voltages typically used in electron energy loss spectroscopy studies. Correspondingly, we measured an energy loss spectrum time series at 100 kV that provides direct evidence for such conversions in nitrogen-doped single-walled carbon nanotubes, in excellent agreement with our theoretical prediction. Besides providing an improved understanding of the irradiation stability of these structures, we show that structural changes cannot be neglected in their characterization employing high-energy electrons.

  13. Using a carbon beam as a probe to extract the sensitive volume thickness; Utilisation d'un faisceau de carbon pour extraire le volume sensible

    Energy Technology Data Exchange (ETDEWEB)

    Inguimbert, C.; Duzellier, S. [Office National d' Etudes et de Recherches Aerospatiales (ONERA/DESP), 31 - Toulouse (France); Ecoffet, R. [Centre National d' Etudes Spatiales (CNES), 31 - Toulouse (France)

    1999-07-01

    Most of the models of proton SEUs predictions use the sensitive volume concept. The sensitive region is modeled by a parallelepiped with length l, width w and thickness d, buried at depth h. We propose a new method to extract the sensitive thickness d. The idea is to use low energy, low range ion in order to probe the component to measure the sensitive volume. The thickness d is obtained by de-convoluting the heavy ion upset cross-section curve with the LET (linear energy transfer) curve, both curves being considered as functions of the range of the incident ion. This method has been tested using a beam of carbon ions and the calculated thickness is closed to the theoretical expected value. The deconvolution method which couples together a sensitive thickness d and a charge collection efficiency {alpha} improves the sensitive volume concept.

  14. Chemical Investigations of ISOL target units for carbon and nitrogen beams

    CERN Document Server

    Franberg, H; Gäggeler, H W; Köster, U

    2006-01-01

    Radioactive Ion Beams (RIB) are of significant interest in a number of applications. ISOL (Isotope Separation On Line) facilities provide RIB with high beam intensities and good beam quality. An atom that is produced within the ISOL target will first diffuse out from the target material. During the effusion towards the transfer line and into the ion source the many contacts with the surrounding surfaces may cause unacceptable delays in the transport and, hence, losses of the shorter-lived isotopes. We performed systematic chemical investigations of adsorption in a temperature and concentration regime relevant for ISOL targets and ion source units, with regard to COx and NOx on Al2O3 and SiO2. These materials are potential construction materials for the above mentioned areas. Off-line and on-line tests have been performed using a gas thermo-chromatography set-up with radioactive tracers. The experiments were performed at the PROTRAC facility at Paul Scherrer Institute in Villigen, Switzerland.

  15. A Study of Charged Current Single Charged Pion Productions on Carbon in a Few-GeV Neutrino Beam

    Energy Technology Data Exchange (ETDEWEB)

    Hiraide, Katsuki; /Kyoto U.

    2009-01-01

    Understanding single charged pion production via neutrino-nucleus charged current interaction in the neutrino energy region of a few GeV is essential for future neutrino oscillation experiments since this process is a dominant background for {nu}{sub {mu}} {yields} {nu}{sub x} oscillation measurements. There are two contributions to this process: single pion production via baryonic resonance ({nu}{sub {mu}}N {yields} {mu}{sup -} N{pi}{sup +}) and coherent pion production interacting with the entire nucleus ({nu}{sub {mu}}A {yields} {mu}{sup -} A{pi}{sup +}), where N is nucleon in the nucleus and A is the nucleus. The purpose of the study presented in this thesis is a precise measurement of charged current single charged pion productions, resonant and coherent pion productions, with a good final state separation in the neutrino energy region of a few GeV. In this thesis, we focus on the study of charged current coherent pion production from muon neutrinos scattering on carbon, {nu}{sub {mu}} {sup 12}C {yields} {mu}{sup -12}C{pi}{sup +}, in the SciBooNE experiment. This is motivated by the fact that without measuring this component first, the precise determination of resonant pion production cross section can not be achieved since the contribution of coherent pion production in the region of small muon scattering angle is not small. Furthermore, the coherent process is particularly interesting because it is deeply rooted in fundamental physics via Adler's partially conserved axial-vector current theorem. We took data from June 2007 until August 2008, in both the neutrino and antineutrino beam. In total, 2.52 x 10{sup 20} protons on target were collected. We have performed a search for charged current coherent pion production by using SciBooNE's full neutrino data set, corresponding to 0.99 x 10{sup 20} protons on target. No evidence for coherent pion production is observed. We set 90% confidence level upper limits on the cross section ratio of charged

  16. A Study of Charged Current Single Charged Pion Productions on Carbon in a Few-GeV Neutrino Beam

    Energy Technology Data Exchange (ETDEWEB)

    Hiraide, Katsuki [Kyoto Univ. (Japan)

    2009-01-01

    Understanding single charged pion production via neutrino-nucleus charged current interaction in the neutrino energy region of a few GeV is essential for future neutrino oscillation experiments since this process is a dominant background for vμ → vx oscillation measurements. There are two contributions to this process: single pion production via baryonic resonance (vμN → μ-+) and coherent pion production interacting with the entire nucleus (vμA → μ-+), where N is nucleon in the nucleus and A is the nucleus. The purpose of the study presented in this thesis is a precise measurement of charged current single charged pion productions, resonant and coherent pion productions, with a good final state separation in the neutrino energy region of a few GeV. In this thesis, we focus on the study of charged current coherent pion production from muon neutrinos scattering on carbon, vμ 12C → μ-12+, in the SciBooNE experiment. This is motivated by the fact that without measuring this component first, the precise determination of resonant pion production cross section can not be achieved since the contribution of coherent pion production in the region of small muon scattering angle is not small. Furthermore, the coherent process is particularly interesting because it is deeply rooted in fundamental physics via Adler's partially conserved axial-vector current theorem. We took data from June 2007 until August 2008, in both the neutrino and antineutrino beam. In total, 2.52 x 1020 protons on target were collected. We have performed a search for charged current coherent pion production by using SciBooNE's full neutrino data set, corresponding to 0.99 x 1020 protons on target. No evidence for coherent pion production is observed. We set 90% confidence level upper limits on the cross section ratio

  17. Rapid phase-correlated rescanning irradiation improves treatment time in carbon-ion scanning beam treatment under irregular breathing

    Science.gov (United States)

    Mori, Shinichiro; Furukawa, Takuji

    2016-05-01

    To shorten treatment time in pencil beam scanning irradiation, we developed rapid phase-controlled rescanning (rPCR), which irradiates two or more isoenergy layers in a single gating window. Here, we evaluated carbon-ion beam dose distribution with rapid and conventional PCR (cPCR). 4 dimensional computed tomography (4DCT) imaging was performed on 12 subjects with lung or liver tumors. To compensate for intrafractional range variation, the field-specific target volume (FTV) was calculated using 4DCT within the gating window (T20–T80). We applied an amplitude-based gating strategy, in which the beam is on when the tumor is within the gating window defined by treatment planning. Dose distributions were calculated for layered phase-controlled rescanning under an irregular respiratory pattern, although a single 4DCT data set was used. The number of rescannings was eight times. The prescribed doses were 48 Gy(RBE)/1 fr (where RBE is relative biological effectiveness) delivered via four beam ports to the FTV for the lung cases and 45 Gy(RBE)/2 fr delivered via two beam ports to the FTV for the liver cases. In the liver cases, the accumulated dose distributions showed an increased magnitude of hot/cold spots with rPCR compared with cPCR. The results of the dose assessment metrics for the cPCR and rPCR were very similar. The D 95, D max, and D min values (cPCR/rPCR) averaged over all the patients were 96.3  ±  0.9%/96.0  ±  1.2%, 107.3  ±  3.6%/107.1  ±  2.9%, and 88.8  ±  3.2%/88.1  ±  3.1%, respectively. The treatment times in cPCR and rPCR were 110.7 s and 53.5 s, respectively. rPCR preserved dose conformation under irregular respiratory motion and reduced the total treatment time compared with cPCR.

  18. Non-Detection of HC$_{11}$N toward TMC-1: Constraining the Chemistry of Large Carbon-Chain Molecules

    CERN Document Server

    Loomis, Ryan A; Langston, Glen; McGuire, Brett A; Dollhopf, Niklaus M; Burkhardt, Andrew M; Corby, Joanna; Booth, Shawn T; Carroll, P Brandon; Turner, Barry; Remijan, Anthony J

    2016-01-01

    Bell et al. (1997) reported the first detection of the cyanopolyyne HC$_{11}$N toward the cold dark cloud TMC-1; no subsequent detections have been reported toward any source. Additional observations of cyanopolyynes and other carbon-chain molecules toward TMC-1 have shown a log-linear trend between molecule size and column density, and in an effort to further explore the underlying chemical processes driving this trend, we have analyzed GBT observations of HC$_9$N and HC$_{11}$N toward TMC-1. Although we find an HC$_9$N column density consistent with previous values, HC$_{11}$N is not detected and we derive an upper limit column density significantly below that reported in Bell et al. Using a state-of-the-art chemical model, we have investigated possible explanations of non-linearity in the column density trend. Despite updating the chemical model to better account for ion-dipole interactions, we are not able to explain the non-detection of HC$_{11}$N, and we interpret this as evidence of previously unknown ...

  19. Inferring phytoplankton carbon and eco-physiological rates from diel cycles of spectral particulate beam-attenuation coefficient

    Directory of Open Access Journals (Sweden)

    G. Dall'Olmo

    2011-03-01

    Full Text Available The diurnal fluctuations in solar irradiance impose a fundamental frequency on ocean biogeochemistry. Observations of the ocean carbon cycle at these frequencies are rare, but could be considerably expanded by measuring and interpreting the inherent optical properties. A method is presented to analyze diel cycles in particulate beam-attenuation coefficient (cp measured at multiple wavelengths. The method is based on fitting observations with a size-structured population and optical model to infer the particle size distribution and physiologically relevant parameters of the cells responsible for the measured diel cycle in cp. Results show that the information related to size and contained in the spectral data can be exploited to independently estimate growth and loss rates during the day and night. In addition, the model can characterize the population of particles affecting the cp diel variability. Application of this method to spectral cp measured at a station in the oligotrophic Mediterranean Sea suggests that most of the observed variations in cp can be ascribed to a synchronized population of cells with an equivalent spherical diameter between 1 and 4 μm. The inferred carbon biomass of these cells was about 8–13 mg m−3 and accounted for approximately 20% of the total particulate organic carbon. If successfully validated and implemented on autonomous platforms, this method could improve our understanding of the ocean carbon cycle.

  20. Imperfection Sensitivity of Nonlinear Vibration of Curved Single-Walled Carbon Nanotubes Based on Nonlocal Timoshenko Beam Theory

    Directory of Open Access Journals (Sweden)

    Iman Eshraghi

    2016-09-01

    Full Text Available Imperfection sensitivity of large amplitude vibration of curved single-walled carbon nanotubes (SWCNTs is considered in this study. The SWCNT is modeled as a Timoshenko nano-beam and its curved shape is included as an initial geometric imperfection term in the displacement field. Geometric nonlinearities of von Kármán type and nonlocal elasticity theory of Eringen are employed to derive governing equations of motion. Spatial discretization of governing equations and associated boundary conditions is performed using differential quadrature (DQ method and the corresponding nonlinear eigenvalue problem is iteratively solved. Effects of amplitude and location of the geometric imperfection, and the nonlocal small-scale parameter on the nonlinear frequency for various boundary conditions are investigated. The results show that the geometric imperfection and non-locality play a significant role in the nonlinear vibration characteristics of curved SWCNTs.

  1. Compilation of erosion yields of metal-doped carbon materials by deuterium impact from ion beam and low temperature plasma

    Energy Technology Data Exchange (ETDEWEB)

    Balden, M., E-mail: Martin.Balden@ipp.mpg.de [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, 85748 Garching (Germany); Starke, P. [Lehrstuhl fuer Experimentelle Plasmaphysik, Institut fuer Physik, Universitaet Augsburg, D-86135 Augsburg (Germany); Garcia-Rosales, C. [CEIT and Tecnun (University of Navarra), E-20018 San Sebastian (Spain); Adelhelm, C.; Sauter, P.A. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, 85748 Garching (Germany); Lopez-Galilea, I.; Ordas, N. [CEIT and Tecnun (University of Navarra), E-20018 San Sebastian (Spain); Fernandez, J.M. Ramos; Escandell, M. Martinez [Departamento de Quimica Inorganica, University of Alicante, E-03690 Alicante (Spain)

    2011-10-01

    The erosion yield by deuterium impact was determined for various doped carbon-based materials. Ion beam bombardment with 30 and 200 eV at elevated temperatures (600-850 K) and low temperature plasma exposure with 30 eV ion energy ({approx}7 x 10{sup 20} ions/m{sup 2}s) and about 170 times higher thermal atomic deuterium flux at 300 K and 630 K were performed. The total yield of fine-grain graphites doped with 4 at.% Ti and Zr is reduced by a factor of 4 for 30 and 200 eV D impact at elevated temperatures at D fluences above 10{sup 24} m{sup -2} compared to undoped graphite. Extensive carbide particle loss can be excluded up to fluences of {approx}10{sup 25} m{sup -2}.

  2. Preparation of diamond-like carbon and boron nitirde films by high-intensity pulsed ion beam deposition

    Energy Technology Data Exchange (ETDEWEB)

    Rej, D.J.; Davis, H.A. [Los Alamos National Lab., NM (United States); Remnev, G.E. [Tomsk Polytechnic Univ., Tomsk (Russian Federation). Nuclear Physics Institute.] [and others

    1995-05-01

    Intense ion beams (300-keV C{sup +}, O{sup +}, and H{sup +}, 20--30 kA, 50 to 400-ns pulsewidth, up to 0.3-Hz repetition rate) were used to prepare diamond-like carbon (DLC) and boron nitride (BN) films. Deposition rates of up to 25{plus_minus}5 nm/pulse were obtained with instantaneous rates exceeding 1 mm/s. Most films were uniform, light brown, translucent, and nonporous with some micron-size particulates. Raman and parallel electron energy loss spectroscopy indicated the presence of DLC. The films possessed favorable electron field-emission characteristics desirable for cold-cathode displays. Transmission electron microscopy (TEM) and transmission electron diffraction (TED) revealed that the C films contained diamond crystals with 25 to 125-nm grain size. BN films were composed of hexagonal, cubic and wurtzite phases.

  3. Radiosensitivity of cancer cells against carbon-ion beams in an aspect of the p53 gene status

    International Nuclear Information System (INIS)

    We can easily understand that radiation sensitivities of cancer cells are dependent on the status of cancer-related genes. It is important to clarify which genes affect radiation sensitivity and reflect the effectiveness of radiation therapy for cancer cells. We have studied about the function of a tumor suppressor gene of p53, because p53 controls apoptosis, cell cycle and DNA repair from an aspect of important roles in cell fate. By analysis of function of p53 gene, therefore, we aim to predict the therapeutic effectiveness and to select the modalities of cancer therapies such as radiotherapy, chemotherapy and hyperthermia. As a final goal, we want to accept the most effective therapy, namely tailor-made cancer therapy, for each patient. Here, we introduce that carbon-beam therapy induced the expression of p53-independent apoptosis-related genes and NO radicals in mutated p53 cancer cells. (author)

  4. Measurement of neutral current coherent neutral pion production on carbon in a few-GeV neutrino beam

    CERN Document Server

    Kurimoto, Y; Brice, S J; Bugel, L; Catala-Perez, J; Cheng, G; Conrad, J M; Djurcic, Z; Dore, U; Finley, D A; Franke, A J; Giganti, C; Gomez-Cadenas, J J; Guzowski, P; Hanson, A; Hayato, Y; Hiraide, K; Jover-Manas, G; Karagiorgi, G; Katori, T; Kobayashi, Y K; Kobilarcik, T; Kubo, H; Louis, W C; Loverre, P F; Ludovici, L; Mahn, K B M; Mariani, C; Masuike, S; Matsuoka, K; McGary, V T; Metcalf, W; Mills, G B; Mitsuka, G; Miyachi, Y; Mizugashira, S; Moore, C D; Nakajima, Y; Nakaya, T; Napora, R; Nienaber, P; Orme, D; Otani, M; Russell, A D; Sanchez, F; Shaevitz, M H; Shibata, T -A; Sorel, M; Stefanski, R J; Takei, H; Tanaka, H -K; Tanaka, M; Tayloe, R; Taylor, I J; Tesarek, R J; Uchida, Y; Van de Water, R; Walding, J J; Wascko, M O; White, H B; Wilking, M J; Yokoyama, M; Zeller, G P; Zimmerman, E D

    2010-01-01

    The SciBooNE Collaboration reports a measurement of neutral current coherent neutral pion production on carbon by a muon neutrino beam with average energy 0.8 GeV. The separation of coherent from inclusive neutral pion production has been improved by detecting recoil protons from resonant neutral pion production. We measure the ratio of the neutral current coherent neutral pion production to total charged current cross sections to be (1.16 +/- 0.24) x 10-2. The ratio of charged current coherent pion to neutral current coherent pion production is calculated to be 0.14+0.30 -0.28, using our published charged current coherent pion measurement.

  5. The use of multi-gap resistive plate chambers for in-beam PET in proton and carbon ion therapy

    CERN Document Server

    Watts, David; Sauli, Fabio; Amaldi, Ugo

    2013-01-01

    On-line verification of the delivered dose during proton and carbon ion radiotherapy is currently a very desirable goal for quality assurance of hadron therapy treatment plans. In-beam positron emission tomography (ibPET), which can provide an image of the β+ activity induced in the patient during irradiation, which in turn is correlated to the range of the ion beam, is one of the modalities for achieving this goal. Application to hadron therapy requires that the scanner geometry be modified from that which is used in nuclear medicine. In particular, PET detectors that allow a sub-nanosecond time-of-flight (TOF) registration of the collinear photons have been proposed. Inclusion of the TOF information in PET data leads to more effective PET sensitivity. Considering the challenges inherent in the ibPET technique, namely limited β+ activity and the effect of biological washout due to blood flow, TOF-PET technologies are very attractive. In this context, the TERA Foundation is investigating the use of resistiv...

  6. Radiosensitivity and Induction of Apoptosis by High LET Carbon Ion Beam and Low LET Gamma Radiation: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Atanu Ghorai

    2014-01-01

    Full Text Available Cancer treatment with high LET heavy ion beam, especially, carbon ion beam (12C, is becoming very popular over conventional radiotherapy like low LET gamma or X-ray. Combination of Poly(ADP-ribose polymerase (PARP inhibitor with xenotoxic drugs or conventional radiation (gamma or X-ray is the newer approach for cancer therapy. The aim of our study was to compare the radiosensitivity and induction of apoptosis by high LET 12C and low LET gamma radiation in HeLa and PARP-1 knocked down cells. We did comet assay to detect DNA breaks, clonogenic survival assay, and cell cycle analysis to measure recovery after DNA damage. We measured apoptotic parameters like nuclear fragmentation and caspase-3 activation. DNA damage, cell killing, and induction of apoptosis were significantly higher for 12C than gamma radiation in HeLa. Cell killing and apoptosis were further elevated upon knocking down of PARP-1. Both 12C and gamma induced G2/M arrest although the 12C had greater effect. Unlike the gamma, 12C irradiation affects DNA replication as detected by S-phase delay in cell cycle analysis. So, we conclude that high LET 12C has greater potential over low LET gamma radiation in killing cells and radiosensitization upon PARP-1 inhibition was several folds greater for 12C than gamma.

  7. Effects of E-Beam Irradiation on the Chemical, Physical, and Electrochemical Properties of Activated Carbons for Electric Double-Layer Capacitors

    Directory of Open Access Journals (Sweden)

    Min-Jung Jung

    2015-01-01

    Full Text Available Activated carbons (ACs were modified via e-beam irradiation at various doses for use as an electrode material in electric double-layer capacitors (EDLCs. The chemical compositions of the AC surfaces were largely unchanged by the e-beam irradiation. The ACs treated with the e-beam at radiation doses of 200 kGy exhibited higher nanocrystallinity than the untreated ACs. The specific surface areas and pore volumes of the e-beam irradiated ACs were also higher than those of the untreated ACs. These results were attributed to the transformation and degradation of the nanocrystallinity of the AC surfaces due to the e-beam irradiation. The specific capacitance of the ACs treated with the e-beam at radiation doses of 200 kGy increased by 24% compared with the untreated ACs, and the charge transfer resistance of the ACs was decreased by the e-beam irradiation. The enhancement of the electrochemical properties of the e-beam irradiated ACs can be attributed to an increase in their specific surface area and surface crystallinity.

  8. Carbon-11 and fluorine-18 chemistry devoted to molecular probes for imaging the brain with positron emission tomography

    International Nuclear Information System (INIS)

    Exploration of the living human brain in real-time and in a noninvasive way was for centuries only a dream, made, however, possible today with the remarkable development during the four last decades of powerful molecular imaging techniques, and especially positron emission tomography (PET). Molecular PET imaging relies, from a chemical point of view, on the use and preparation of a positron-emitting radiolabelled probe or radiotracer, notably compounds incorporating one of two short-lived radionuclides fluorine-18 (T1/2: 109.8 min) and carbon-11 (T1/2: 20.38 min). The growing availability and interest for the radio-halogen fluorine-18 in radiopharmaceutical chemistry undoubtedly results from its convenient half-life and the successful use in clinical oncology of 2-[18F]fluoro-2-deoxy-D-glucose ([18F]FDG). The special interest of carbon-11 is not only that carbon is present in virtually all biomolecules and drugs allowing therefore for isotopic labelling of their chemical structures but also that a given molecule could be radiolabelled at different functions or sites, permitting to explore (or to take advantage of) in vivo metabolic pathways. PET chemistry includes production of these short-lived radioactive isotopes via nuclear transmutation reactions using a cyclotron, and is directed towards the development of rapid synthetic methods, at the trace level, for the introduction of these nuclides into a molecule, as well as the use of fast purification, analysis and formulation techniques. PET chemistry is the driving force in molecular PET imaging, and this special issue of the Journal of Labelled Compounds and Radiopharmaceuticals, which is strongly chemistry and radiochemistry-oriented, aims at illustrating, be it in part only, the state-of-the-art arsenal of reactions currently available and its potential for the research and development of specific molecular probes labelled with the positron emitters carbon-11 and fluorine-18,with optimal imaging properties for

  9. Carbon-11 labelled ketamine-synthesis, distribution in mice and PET studies in baboons

    Energy Technology Data Exchange (ETDEWEB)

    Shiue, C.-Y.; Vallabhahosula, Shankar; Wolf, Alfred P.; Dewey, Stephen L.; Fowler, Joanna S.; Schlyer, David J.; Arnett, Carroll D.; Zhou Yiguo

    1997-02-01

    No-carrier-added (NCA)[{sup 11}C]({+-})-ketamine (2a) and its enantiomers (+)-2b and (-)-2c were synthesized by methylation of the corresponding norketamine (1a-c) with [{sup 11}C]H{sub 3}I in an overall radiochemical yield of 20% (EOB) with specific activities of 0.35-0.45 Ci/{mu}mole at EOB in a synthesis time of 40 min from EOB. Compound 2a was metabolized rapidly in mouse brain and labeled metabolites appeared in baboon plasma. PET studies of compounds 2a-c in a baboon showed that influx of compounds 2a-c into the brain was high for the first few min but radioactivity then declined rapidly. Although the retention of radioactivity in the baboon striatum was not significantly different for 2a-c 20 min post-injection, graphical analysis of time-activity data for each enantiomer and for the racemate in baboon striatum suggested that (+)-ketamine may interact with receptors slightly more effectively than its (-)-enantiomer or racemate. However, due to its rapid metabolism in the brain and a similar uptake in the striatum and cerebellum, [{sup 11}C]ketamine may not be an ideal tracer for studying NMDA receptor with PET.

  10. Investigations of acetonitrile solvent cluster formation in supercritical carbon dioxide, and its impact on microscale syntheses of carbon-11-labeled radiotracers for PET

    International Nuclear Information System (INIS)

    A new strategy has been developed for synthesizing positron emission tomography (PET) radiotracers using [11C]methyl iodide. This strategy relies on the ability of organic co-solvents to cluster within mixtures of supercritical fluids resulting in localized regions of high density which can serve as microscopic pockets for reaction. We've shown that acetonitrile will cluster about dilute solutes when mixtures of this co-solvent with carbon dioxide are forced to behave as a homogeneous fluid at the critical point. We applied this strategy in a systematic investigation of the conditions for optimized reaction between methyl iodide and L-α-methyl-N-2-propynyl phenethylamine (nordeprenyl) to yield L-deprenyl. Variables such as temperature, ultraviolet light exposure, co-solvent concentration, system pressure, and methyl iodide concentration were explored. The synthesis of radioactive [11C]-L-deprenyl using no-carrier-added concentrations of [11C]methyl iodide was also tested. Results showed that greater than 90% radiochemical yield of the desired product could be attained using 40 times less labeling substrate than in conventional PET tracer syntheses

  11. Search for Charged Current Coherent Pion Production on Carbon in a Few-GeV Neutrino Beam

    Energy Technology Data Exchange (ETDEWEB)

    Hiraide, K.; /Kyoto U.; Alcaraz-Aunion, J.L.; /Barcelona, IFAE; Brice, S.J.; /Fermilab; Bugel, Leonard G.; /MIT; Catala-Perez, J.; /Valencia U.; Cheng, G.; /Columbia U.; Conrad, J.M.; /MIT; Djurcic, Zelimir; /Columbia U.; Dore, U.; /Banca di Roma /Frascati; Finley, David A.; /Fermilab; Franke, A.J.; /Columbia U. /Banca di Roma /Frascati

    2008-11-01

    The SciBooNE Collaboration has performed a search for charged current coherent pion production from muon neutrinos scattering on carbon, nu{sub {mu}}{sup 12}C- {yields} {mu}{sup 12}Cpi{sup +}, with two distinct data samples. No evidence for coherent pion production is observed. We set 90% confidence level upper limits on the cross section ratio of charged current coherent pion production to the total charged current cross section at 0.67 x 10{sup -2} at mean neutrino energy 1.1 GeV and 1.36 x 10{sup -2} at mean neutrino energy 2.2 GeV.

  12. Design and characterization of a multi-beam micro-CT scanner based on carbon nanotube field emission x-ray technology

    Science.gov (United States)

    Peng, Rui

    In this dissertation, I will present the results for my Ph.D. research for the past five years. My project mainly focuses on advanced imaging applications with a multi-beam x-ray source array based on carbon nanotube field emission technology. In the past few years, research in carbon nanotubes gradually changed from the raw material science to its application. Field emission x-ray application is one of the hottest research areas for carbon nanotube. Compared to traditional thermionic x-ray sources, the carbon nanotube field emission x-ray source has some natural advantages over traditional thermionic x-ray sources such as instantaneous x-ray generation, programmability and miniaturization. For the past few years, the research and development of carbon nanotube field emission x-ray has shifted from single x-ray beam applications to spatially distributed multi-beam x-ray sources. Previously in Zhou group, we have already built a gated micro-CT system with single beam micro-focus x-ray tube for higher spatial and temporal resolution as required in live animal imaging and a multi-beam tomosynthesis system targeting for faster and more stable breast imaging. Now my project mainly focused on the design, characterization and optimization of a multi-beam micro-CT imaging system. With the increase of gantry rotation speed approaching the mechanical limit, it is getting more and more difficult to further speed up the CT scanning. My new system promises a potential solution for the problem, and it serves as a great test platform for truly stationary micro-CT geometry. The potential capabilities it showed during the characterization and imaging measurements was promising. The dissertation is composed of five chapters. In Chapter 1, I will generally review the physics principles of x-ray generation and interaction with matter. Then the discovery of carbon nanotube and its great potential to serve as an excellent field emission electron source will be introduced in the second

  13. Carbon-ion beams induce production of an immune mediator protein, high mobility group box 1, at levels comparable with X-ray irradiation

    International Nuclear Information System (INIS)

    X-ray radiotherapy activates tumor antigen-specific T-cell responses, and increases in the serum levels of high mobility group box 1 (HMGB1) induced by X-ray irradiation play a pivotal role in activating anti-tumor immunity. Here, we examined whether carbon-ion beams, as well as X-rays, can induce HMGB1 release from human cancer cell lines. The study examined five human cancer cell lines: TE2, KYSE70, A549, NCI-H460 and WiDr. The proportion of cells surviving X- or carbon-ion beam irradiation was assessed in a clonogenic assay. The D10, the dose at which 10% of cells survive, was calculated using a linear–quadratic model. HMGB1 levels in the culture supernatants were assessed by an ELISA. The D10 dose for X-rays in TE2, KYSE70, A549, NCI-H460 and WiDr cells was 2.1, 6.7, 8.0, 4.8 and 7.1 Gy, respectively, whereas that for carbon-ion beams was 0.9, 2.5, 2.7, 1.8 and 3.5 Gy, respectively. X-rays and carbon-ion beams significantly increased HMGB1 levels in the culture supernatants of A549, NCI-H460 and WiDr cells at 72 h post-irradiation with a D10 dose. Furthermore, irradiation with X-rays or carbon-ion beams significantly increased HMGB1 levels in the culture supernatants of all five cell lines at 96 h post-irradiation. There was no significant difference in the amount of HMGB1 induced by X-rays and carbon-ion beams at any time-point (except at 96 h for NCI-H460 cells); thus we conclude that comparable levels of HMGB1 were detected after irradiation with iso-survival doses of X-rays and carbon-ion beams. (author)

  14. Ion Beam Induced Charge Collection (IBICC) from Integrated Circuit Test Structures Using a 10 MeV Carbon Microbeam

    Energy Technology Data Exchange (ETDEWEB)

    Aton, T.J.; Doyle, B.L.; Duggan, J.L.; El Bouanani, M.; Guo, B.N.; McDaniel, F.D.; Renfrow, S.N.; Walsh, D.S.

    1998-11-18

    As future sizes of Integrated Circuits (ICs) continue to shrink the sensitivity of these devices, particularly SRAMs and DRAMs, to natural radiation is increasing. In this paper, the Ion Beam Induced Charge Collection (IBICC) technique is utilized to simulate neutron-induced Si recoil effects in ICS. The IBICC measurements, conducted at the Sandia National Laboratories employed a 10 MeV carbon microbeam with 1pm diameter spot to scan test structures on specifically designed ICS. With the aid of layout information, an analysis of the charge collection efficiency from different test areas is presented. In the present work a 10 MeV Carbon high-resolution microbeam was used to demonstrate the differential charge collection efficiency in ICS with the aid of the IC design Information. When ions strike outside the FET, the charge was only measured on the outer ring, and decreased with strike distance from this diode. When ions directly strike the inner and ring diodes, the collected charge was localized to these diodes. The charge for ions striking the gate region was shared between the inner and ring diodes. I The IBICC measurements directly confirmed the interpretations made in the earlier work.

  15. Hypofractionated carbon ion therapy delivered with scanned ion beams for patients with hepatocellular carcinoma – feasibility and clinical response

    International Nuclear Information System (INIS)

    Photon-based radiation therapy does currently not play a major role as local ablative treatment for hepatocellular carcinoma (HCC). Carbon ions offer distinct physical and biological advantages. Due to their inverted dose profile and the high local dose deposition within the Bragg peak, precise dose application and sparing of normal tissue is possible. Furthermore, carbon ions have an increased relative biological effectiveness (RBE) compared to photons. A total of six patients with one or more HCC-lesions were treated with carbon ions delivered by the raster-scanning technique according to our clinical trial protocol. Diagnosis of HCC was confirmed by histology or two different imaging modalities (CT and MRI) according to the AASLD-guidelines. Applied fractionation scheme was 4 × 10 Gy(RBE). Correct dose application was controlled by in-vivo PET measurement of β + −activity in the irradiated tissue shortly after treatment. Patients were observed for a median time period of 11.0 months (range, 3.4 – 12.7 months). Imaging studies showed a partial response in 4/7 lesions and a stable disease in 3/7 lesions in follow-up CT- and MRI scans. Local control was 100%. One patient with multifocal intrahepatic disease underwent liver transplantation 3 months after carbon ion therapy. During radiotherapy and the follow-up period no severe adverse events have occurred. We report the first clinical results of patients with HCC undergoing carbon ion therapy using the rasterscanning technique at our institution. All patients are locally controlled and experienced no higher toxicities in a short follow-up period. Further patients will be included in our prospective Phase-I clinical trial PROMETHEUS-01 (NCT01167374)

  16. Properties of Lithium-11 and Carbon-22 at leading order in halo effective field theory

    Directory of Open Access Journals (Sweden)

    Acharya Bijaya

    2016-01-01

    Full Text Available We study the 11Li and 22C nuclei at leading order (LO in halo effective field theory (Halo EFT. Using the value of the 22C rms matter radius deduced in Ref. [1] as an input in a LO calculation, we simultaneously constrain the values of the two-neutron (2n separation energy of 22C and the virtual-state energy of the 20C−neutron system (hereafter denoted 21C. The 1−σ uncertainty of the input rms matter radius datum, along with the theory error estimated from the anticipated size of the higher-order terms in the Halo EFT expansion, gives an upper bound of about 100 keV for the 2n separation energy. We also study the electric dipole excitation of 2n halo nuclei to a continuum state of two neutrons and the core at LO in Halo EFT. We first compare our results with the 11Li data from a Coulomb dissociation experiment and obtain good agreement within the theoretical uncertainty of a LO calculation. We then obtain the low-energy spectrum of B(E1 of this transition at several different values of the 2n separation energy of 22C and the virtual-state energy of 21C. Our predictions can be compared to the outcome of an ongoing experiment on the Coulomb dissociation of 22C to obtain tighter constraints on the two- and three-body energies in the 22C system.

  17. Properties of Lithium-11 and Carbon-22 at leading order in halo effective field theory

    CERN Document Server

    Acharya, Bijaya

    2015-01-01

    We study the $^{11}\\mathrm{Li}$ and $^{22}\\mathrm{C}$ nuclei at leading order (LO) in halo effective field theory (Halo EFT). Using the value of the $^{22}\\mathrm{C}$ rms matter radius deduced in Ref. [1] as an input in a LO calculation, we simultaneously constrained the values of the two-neutron (2$n$) separation energy of $^{22}\\mathrm{C}$ and the virtual-state energy of the $^{20}\\mathrm{C}-$neutron system (hereafter denoted $^{21}$C). The 1$-\\sigma$ uncertainty of the input rms matter radius datum, along with the theory error estimated from the anticipated size of the higher-order terms in the Halo EFT expansion, gave an upper bound of about 100 keV for the 2$n$ separation energy. We also study the electric dipole excitation of 2$n$ halo nuclei to a continuum state of two neutrons and the core at LO in Halo EFT. We first compare our results with the $^{11}\\mathrm{Li}$ data from a Coulomb dissociation experiment and obtain good agreement within the theoretical uncertainty of a LO calculation. We then obtai...

  18. Properties of Lithium-11 and Carbon-22 at leading order in halo effective field theory

    Science.gov (United States)

    Acharya, Bijaya; Phillips, Daniel R.

    2016-03-01

    We study the 11Li and 22C nuclei at leading order (LO) in halo effective field theory (Halo EFT). Using the value of the 22C rms matter radius deduced in Ref. [1] as an input in a LO calculation, we simultaneously constrain the values of the two-neutron (2n) separation energy of 22C and the virtual-state energy of the 20C-neutron system (hereafter denoted 21C). The 1-σ uncertainty of the input rms matter radius datum, along with the theory error estimated from the anticipated size of the higher-order terms in the Halo EFT expansion, gives an upper bound of about 100 keV for the 2n separation energy. We also study the electric dipole excitation of 2n halo nuclei to a continuum state of two neutrons and the core at LO in Halo EFT. We first compare our results with the 11Li data from a Coulomb dissociation experiment and obtain good agreement within the theoretical uncertainty of a LO calculation. We then obtain the low-energy spectrum of B(E1) of this transition at several different values of the 2n separation energy of 22C and the virtual-state energy of 21C. Our predictions can be compared to the outcome of an ongoing experiment on the Coulomb dissociation of 22C to obtain tighter constraints on the two- and three-body energies in the 22C system.

  19. Detection of Local, Regional, and Distant Recurrence in Patients With PSA Relapse After External-Beam Radiotherapy Using 11C-Choline Positron Emission Tomography

    International Nuclear Information System (INIS)

    Purpose: An elevated serum prostate-specific antigen (PSA) level cannot distinguish between local-regional recurrences and the presence of distant metastases after treatment with curative intent for prostate cancer. With the advent of salvage treatment such as cryotherapy, it has become important to localize the site of recurrence (local or distant). In this study, the potential of 11C-choline positron emission tomography (PET) to identify site of recurrence was investigated in patients with rising PSA after external-beam radiotherapy (EBRT). Methods and Materials: Seventy patients with histologically proven prostate cancer treated with EBRT and showing biochemical recurrence as defined by American Society for Therapeutic Radiology and Oncology consensus statement and 10 patients without recurrence underwent a PET scan using 400 MBq 11C-choline intravenously. Biopsy-proven histology from the site of suspicion, findings with other imaging modalities, clinical follow-up and/or response to adjuvant therapy were used as comparative references. Results: None of the 10 patients without biochemical recurrence had a positive PET scan. Fifty-seven of 70 patients with biochemical recurrence (median PSA 9.1 ng/mL; mean PSA 12.3 ng/mL) showed an abnormal uptake pattern (sensitivity 81%). The site of recurrence was only local in 41 of 57 patients (mean PSA 11.1 ng/mL at scan), locoregionally and/or distant in 16 of 57 patients (mean PSA 17.7 ng/mL). Overall the positive predictive value and negative predictive value for 11C-choline PET scan were 1.0 and 0.44 respectively. Accuracy was 84%. Conclusions: 11C-choline PET scan is a sensitive technique to identify the site of recurrence in patients with PSA relapse after EBRT for prostate cancer.

  20. Inferring phytoplankton carbon and eco-physiological rates from diel cycles of spectral particulate beam-attenuation coefficient

    Directory of Open Access Journals (Sweden)

    G. Dall'Olmo

    2011-11-01

    Full Text Available The diurnal fluctuations in solar irradiance impose a fundamental frequency on ocean biogeochemistry. Observations of the ocean carbon cycle at these frequencies are rare, but could be considerably expanded by measuring and interpreting the inherent optical properties. A method is presented to analyze diel cycles in particulate beam-attenuation coefficient (cp measured at multiple wavelengths. The method is based on fitting observations with a size-structured population model coupled to an optical model to infer the particle size distribution and physiologically relevant parameters of the cells responsible for the measured diel cycle in cp. Results show that the information related to size and contained in the spectral data can be exploited to independently estimate growth and loss rates during the day and night. In addition, the model can characterize the population of particles affecting the diel variability in cp. Application of this method to spectral cp measured at a station in the oligotrophic Mediterranean Sea suggests that most of the observed variations in cp can be ascribed to a synchronized population of cells with an equivalent spherical diameter around 4.6±1.5 μm. The inferred carbon biomass of these cells was about 5.2–6.0 mg m−3 and accounted for approximately 10% of the total particulate organic carbon. If successfully validated, this method may improve our in situ estimates of primary productivity.

  1. Carbon-11 epidepride: a suitable radioligand for PET investigation of striatal and extrastriatal dopamine D{sub 2} receptors

    Energy Technology Data Exchange (ETDEWEB)

    Langer, Oliver; Halldin, Christer E-mail: christer.halldin@neuro.ks.se; Dolle, Frederic; Swahn, Carl-Gunnar; Olsson, Hans; Lundkvist, Per Karlsson; Hall, Haakan; Sandell, Johan; Vaufrey, Camilla; Loc' h, Christian; Franzoise; Crouzel, Christian; Maziere, Bernard; Farde, Lars

    1999-07-01

    Epidepride {l_brace}(S)-(-)-N-([1-ethyl-2-pyrrolidinyl]methyl)-5-iodo-2,3-dimethoxybenzamide= {r_brace} binds with a picomolar affinity (K{sub i}=24 pM) to the dopamine D{sub 2} receptor. Iodine-123-labeled epidepride has been used previously to study striatal and extrastriatal dopamine D{sub 2} receptors with single photon emission computed tomography (SPECT). Our aim was to label epidepride with carbon-11 for comparative quantitative studies between positron emission tomography (PET) and SPECT. Epidepride was synthesized from its bromo-analogue FLB 457 via the corresponding trimethyl-tin derivative. In an alternative synthetic pathway, the corresponding substituted benzoic acid was reacted with the optically pure aminomethylpyrrolidine-derivative. Demethylation of epidepride gave the desmethyl-derivative, which was reacted with [{sup 11}C]methyl triflate. Total radiochemical yield was 40-50% within a total synthesis time of 30 min. The specific radioactivity at the end of synthesis was 37-111 GBq/{mu}mol (1,000-3,000 Ci/mmol). Human postmortem whole-hemisphere autoradiography demonstrated dense binding in the caudate putamen, and also in extrastriatal areas such as the thalamus and the neocortex. The binding was inhibited by unlabeled raclopride. PET studies in a cynomolgus monkey demonstrated high uptake in the striatum and in several extrastriatal regions. At 90 min after injection, uptake in the striatum, thalamus and neocortex was about 11, 4, and 2 times higher than in the cerebellum, respectively. Pretreatment experiment with unlabeled raclopride (1 mg/kg) inhibited 50-70% of [{sup 11}C]epidepride binding. The fraction of unchanged [{sup 11}C]epidepride in monkey plasma determined by a gradient high performance liquid chromatography (HPLC) method was about 30% of the total radioactivity at 30 min after injection of [{sup 11}C]epidepride. The availability of [{sup 11}C]epidepride allows the PET-verification of the data obtained from quantitation studies with

  2. Single-walled carbon nanotubes and nanocrystalline graphene reduce beam-induced movements in high-resolution electron cryo-microscopy of ice-embedded biological samples

    CERN Document Server

    Rhinow, Daniel; Turchanin, Andrey; Gölzhäuser, Armin; Kühlbrandt, Werner; 10.1063/1.3645010

    2011-01-01

    For single particle electron cryo-microscopy (cryoEM), contrast loss due to beam-induced charging and specimen movement is a serious problem, as the thin films of vitreous ice spanning the holes of a holey carbon film are particularly susceptible to beam-induced movement. We demonstrate that the problem is at least partially solved by carbon nanotechnology. Doping ice-embedded samples with single-walled carbon nanotubes (SWNT) in aqueous suspension or adding nanocrystalline graphene supports, obtained by thermal conversion of cross-linked self-assembled biphenyl precursors, significantly reduces contrast loss in high-resolution cryoEM due to the excellent electrical and mechanical properties of SWNTs and graphene.

  3. [11C]Carbon Monoxide in Palladium- / Selenium-Promoted Carbonylation Reactions : Synthesis of 11C-Imides, Hydrazides, Amides, Carboxylic Acids, Carboxylic Esters, Carbothioates, Ketones and Carbamoyl Compounds

    OpenAIRE

    Karimi, Farhad

    2002-01-01

    [11C]Carbon monoxide in low concentrations has been used in palladium- or seleniummediated carbonylation reactions such as the synthesis of 11C-imides, hydrazides, amides, carboxylic acids, esters, carbothioates, ketones and carbamoyl compounds. In these reactions aryl iodides have been used in most cases. However, less reactive aryl triflate, chloride and bromides were activated using tetrabutylammonium iodide. The reactivities of nucleophiles may have influence on the radiochemical yield of...

  4. Analysis of the fine structure of Sn11 +-Sn14 + ions by optical spectroscopy in an electron-beam ion trap

    Science.gov (United States)

    Windberger, A.; Torretti, F.; Borschevsky, A.; Ryabtsev, A.; Dobrodey, S.; Bekker, H.; Eliav, E.; Kaldor, U.; Ubachs, W.; Hoekstra, R.; Crespo López-Urrutia, J. R.; Versolato, O. O.

    2016-07-01

    We experimentally re-evaluate the fine structure of Sn11 +-Sn14 + ions. These ions are essential in bright extreme-ultraviolet (EUV) plasma-light sources for next-generation nanolithography, but their complex electronic structure is an open challenge for both theory and experiment. We combine optical spectroscopy of magnetic dipole M 1 transitions, in a wavelength range covering 260 to 780 nm, with charge-state selective ionization in an electron beam ion trap. Our measurements confirm the predictive power of ab initio calculations based on Fock space coupled cluster theory. We validate our line identification using semiempirical cowan calculations with adjustable wave-function parameters. Available Ritz combinations further strengthen our analysis. Comparison with previous work suggests that line identifications in the EUV need to be revisited.

  5. Induction of apoptosis in murione spleen lymphocytes using carbon ion beam

    International Nuclear Information System (INIS)

    To assess the capacity of heavy ions to induce apoptosis in lymphocytes, mice have been irradiated with accelerated carbon ions (95 MeV/nucleon) at doses ranging from 0.1 to 4 Gy. Their spleens were removed 24 h later and gently dissociated to prepare a single cell suspension. Mononuclear cells were then maintained in culture at 37oC, and the occurrence of apoptosis in these cells was analysed 24 h later. Lymphocytes were also irradiated in vitro, in the presence of Ac-DEVD-CHO, a potent caspase-3 and -7 inhibitor. Results from three experiments performed at the Grand Accelerateur National d'Ions Lourds (GANIL, Caen, France) are reported here. They indicate that carbon ions induce a marked, dose-dependent, reduction of the spleen weight and cellularity. However, in sharp contrast with spleen cells prepared from X-ray irradiated mice, only a slight increase of apoptosis is evidenced in cultured lymphocytes from mice irradiated with heavy ions. The significance of such results is discussed. So far, few data exist concerning the biological effects of heavy ions, in particular their capacity to induce apoptosis in lymphocytes; the present study provides useful clues for further investigations. (author)

  6. Mathematical modeling of enzyme production using Trichoderma harzianum P49P11 and sugarcane bagasse as carbon source.

    Science.gov (United States)

    Gelain, Lucas; da Cruz Pradella, José Geraldo; da Costa, Aline Carvalho

    2015-12-01

    A mathematical model to describe the kinetics of enzyme production by the filamentous fungus Trichoderma harzianum P49P11 was developed using a low cost substrate as main carbon source (pretreated sugarcane bagasse). The model describes the cell growth, variation of substrate concentration and production of three kinds of enzymes (cellulases, beta-glucosidase and xylanase) in different sugarcane bagasse concentrations (5; 10; 20; 30; 40 gL(-1)). The 10 gL(-1) concentration was used to validate the model and the other to parameter estimation. The model for enzyme production has terms implicitly representing induction and repression. Substrate variation was represented by a simple degradation rate. The models seem to represent well the kinetics with a good fit for the majority of the assays. Validation results indicate that the models are adequate to represent the kinetics for a biotechnological process. PMID:26378961

  7. Effects of a 2-step culture with cytokine combinations on megakaryocytopoiesis and thrombopoiesis from carbon-ion beam-irradiated human hematopoietic stem/progenitor cells

    International Nuclear Information System (INIS)

    To evaluate whether the continuous treatment of two cytokine combinations is effective in megakaryocytopoiesis and thrombopoiesis in hematopoietic stem/progenitor cells exposed to heavy ion beams, the effects of a 2-step culture by a combination of recombinant human interleukin-3 (IL-3)+stem cell factor (SCF)+thrombopoietin (TPO), which just slightly protected against carbon-ion beam-induced damages, and a combination of IL-3+TPO, which selectively stimulated the differentiation of the hematopoietic stem/progenitor cells to megakaryocytes and platelets, were examined. CD34+-hematopoietic stem/progenitor cells isolated from the human placental and umbilical cord blood were exposed to carbon-ion beams (linear energy transfer (LET)=50 keV/μm) at 2 Gy. These cells were cultured under three cytokine conditions. The number of megakaryocytes, platelets and hematopoietic progenitors were assessed using a flow cytometer and a clonogenic assay at 14 and 21 days after irradiation, respectively. However, the efficacy of each 2-step culture was equal or lower than that of using the IL-3+SCF+TPO combination alone and the 2-step culture could not induce megakaryocytes and platelets from hematopoietic stem/progenitor cells exposed to high LET-radiation such as carbon-ion beams. Therefore, additional cytokines and/or hematopoietic promoting compounds might be required to overcome damage to hematopoietic cells by high LET radiation. (author)

  8. The use of multi-gap resistive plate chambers for in-beam PET in proton and carbon ion therapy

    Science.gov (United States)

    Watts, David; Borghi, Giacomo; Sauli, Fabio; Amaldi, Ugo

    2013-01-01

    On-line verification of the delivered dose during proton and carbon ion radiotherapy is currently a very desirable goal for quality assurance of hadron therapy treatment plans. In-beam positron emission tomography (ibPET), which can provide an image of the β+ activity induced in the patient during irradiation, which in turn is correlated to the range of the ion beam, is one of the modalities for achieving this goal. Application to hadron therapy requires that the scanner geometry be modified from that which is used in nuclear medicine. In particular, PET detectors that allow a sub-nanosecond time-of-flight (TOF) registration of the collinear photons have been proposed. Inclusion of the TOF information in PET data leads to more effective PET sensitivity. Considering the challenges inherent in the ibPET technique, namely limited β+ activity and the effect of biological washout due to blood flow, TOF-PET technologies are very attractive. In this context, the TERA Foundation is investigating the use of resistive plate chambers (RPC) for an ibPET application because of their excellent timing properties and low cost. In this paper we present a novel compact multi-gap RPC (MRPC) module design and construction method, which considering the large number of modules that would be needed to practically implement a high-sensitivity RPC-PET scanner, could be advantageous. Moreover, we give an overview of the efficiency and timing measurements that have been obtained in the laboratory using such single-gap and multi-gap RPC modules. PMID:23824118

  9. Electron-beam induced diamond-like-carbon passivation of plasmonic devices

    Science.gov (United States)

    Balaur, Eugeniu; Sadatnajafi, Catherine; Langley, Daniel; Lin, Jiao; Kou, Shan Shan; Abbey, Brian

    2015-12-01

    Engineered materials with feature sizes on the order of a few nanometres offer the potential for producing metamaterials with properties which may differ significantly from their bulk counterpart. Here we describe the production of plasmonic colour filters using periodic arrays of nanoscale cross shaped apertures fabricated in optically opaque silver films. Due to its relatively low loss in the visible and near infrared range, silver is a popular choice for plasmonic devices, however it is also unstable in wet or even ambient conditions. Here we show that ultra-thin layers of Diamond-Like Carbon (DLC) can be used to prevent degradation due to oxidative stress, ageing and corrosion. We demonstrate that DLC effectively protects the sub-micron features which make up the plasmonic colour filter under both atmospheric conditions and accelerated aging using iodine gas. Through a systematic study we confirm that the nanometre thick DLC layers have no effect on the device functionality or performance.

  10. The EGFR mutation status affects the relative biological effectiveness of carbon-ion beams in non-small cell lung carcinoma cells.

    Science.gov (United States)

    Amornwichet, Napapat; Oike, Takahiro; Shibata, Atsushi; Nirodi, Chaitanya S; Ogiwara, Hideaki; Makino, Haruhiko; Kimura, Yuka; Hirota, Yuka; Isono, Mayu; Yoshida, Yukari; Ohno, Tatsuya; Kohno, Takashi; Nakano, Takashi

    2015-06-11

    Carbon-ion radiotherapy (CIRT) holds promise to treat inoperable locally-advanced non-small cell lung carcinoma (NSCLC), a disease poorly controlled by standard chemoradiotherapy using X-rays. Since CIRT is an extremely limited medical resource, selection of NSCLC patients likely to benefit from it is important; however, biological predictors of response to CIRT are ill-defined. The present study investigated the association between the mutational status of EGFR and KRAS, driver genes frequently mutated in NSCLC, and the relative biological effectiveness (RBE) of carbon-ion beams over X-rays. The assessment of 15 NSCLC lines of different EGFR/KRAS mutational status and that of isogenic NSCLC lines expressing wild-type or mutant EGFR revealed that EGFR-mutant NSCLC cells, but not KRAS-mutant cells, show low RBE. This was attributable to (i) the high X-ray sensitivity of EGFR-mutant cells, since EGFR mutation is associated with a defect in non-homologous end joining, a major pathway for DNA double-strand break (DSB) repair, and (ii) the strong cell-killing effect of carbon-ion beams due to poor repair of carbon-ion beam-induced DSBs regardless of EGFR mutation status. These data highlight the potential of EGFR mutation status as a predictor of response to CIRT, i.e., CIRT may show a high therapeutic index in EGFR mutation-negative NSCLC.

  11. Beam-Beam Effects

    CERN Document Server

    Herr, W

    2014-01-01

    One of the most severe limitations in high-intensity particle colliders is the beam-beam interaction, i.e. the perturbation of the beams as they cross the opposing beams. This introduction to beam-beam effects concentrates on a description of the phenomena that are present in modern colliding beam facilities.

  12. The ''in vivo'' distribution of carbon 11 labeled-nicotine in animals. A method suitable for use in man

    International Nuclear Information System (INIS)

    A method is described to label nicotine with carbon 11. A hundred millicuries can be obtained, in 45 minutes, with a high specific activity. This labeling of nicotine has allowed an ''in vivo'' study of the distribution of this very toxic drug in animals. Five minutes after injection in rabbits or monkeys, it was shown with a gamma camera or with a positron camera that the radioactivity was very rapidly distributed throughout the tissues especially in brain, lungs and kidneys. 11C-nicotine readily penetrates the blood-brain barrier and the brain radioactivity decreases very sharply with time. The eyes however retained activity, possibly in the retina. Unfortunately the monkey is not the ideal subject for 11C-nicotine brain study because: the brain is small, considering the resolution of the cameras and the cerebral lobes are also quite overlaped in this animal; Japanese authors have shown that compared with dogs the nicotine brain uptake is lower, due to the high affinity of nicotine for skeletal muscle which occupies approximately forty to fifty % of the body weight of the monkey. Also in monkeys, the nicotine destruction is faster than in dogs because there is a higher enzyme nicotine metabolizing activity in the liver of this animal. The differences observed between various animals studies using nicotine indicate that we should not draw any firm conclusions about the behaviour of this drug in humans. In order to do so, examinations must be conducted in man and the method described in spite of its limitations provides a means for such a study

  13. Microstructure and property of the Ti-24Al-15Nb-1.5Mo/TC11 joint welded by electron beam welding

    Institute of Scientific and Technical Information of China (English)

    Ying-ying Liu; Ze-kun Yao; Hong-zhen Guo; Hang-hang Yang

    2009-01-01

    The Ti-24Al-15Nb-1.5Mo alloy, in the as-forged and heat-treated states, was joined to the as-forged TC11 titanium alloy by electron beam welding with the heat inputs of 135 and 150 kJ/m. Then the microstructure and property of the Ti-24Al-15Nb-1.5Mo/TC11 welding interface were investigated. The results show that the phase constitution of the weld is not related to the heat input, and is mainly composed of α' phase. Moreover, the intermetallic phases of Ti_2AlNb, MoNb, Nb_3Al, and TiAl_3 are formed in the weld zone. Therefore, the microhardness value of the weld zone is higher than that of the other portions in the same sample. The profile of the weld is asymmetrically funnel-like. The grain sizes of the weld and its heat-affected zones are increased with increasing heat input. There is an obvious difference in the element content of the welding interface; only the alloying elements in the fusion zone reach a new balance during solidification.

  14. Recent advances in electron-beam curing of carbon fiber-reinforced composites

    Science.gov (United States)

    Coqueret, Xavier; Krzeminski, Mickael; Ponsaud, Philippe; Defoort, Brigitte

    2009-07-01

    Cross-linking polymerization initiated by high-energy radiation is a very attractive technique for the fabrication of high-performance composite materials. The method offers many advantages compared to conventional energy- and time-consuming thermal curing processes. Free radical and cationic poly-addition chemistries have been investigated in some details by various research groups along the previous years. A high degree of control over curing kinetics and material properties can be exerted by adjusting the composition of matrix precursors as well as by acting on process parameters. However, the comparison with state-of-the-art thermally cured composites revealed the lower transverse mechanical properties of radiation-cured composites and the higher brittleness of the radiation-cured matrix. Improving fiber-matrix adhesion and upgrading polymer network toughness are thus two major challenges in this area. We have investigated several points related to these issues, and particularly the reduction of the matrix shrinkage on curing, the wettability of carbon fibers, the design of fiber-matrix interface and the use of thermoplastic toughening agents. Significant improvements were achieved on transverse strain at break by applying original surface treatments on the fibers so as to induce covalent coupling with the matrix. A drastic enhancement of the K IC value exceeding 2 MPa m 1/2 was also obtained for acrylate-based matrices toughened with high T g thermoplastics.

  15. Test Measurements of a 20 ms-1 Carbon Wire Beam Scanner

    CERN Document Server

    De Freitas, J; Emery, J; Herranz Alvarez, J F; Koujili, M; Ramos, D; Sapinski, M; Ait-Amira, Y; Djerdir, A

    2011-01-01

    This paper pre­sents the de­sign of the ac­tu­a­tor for the fast and high ac­cu­ra­cy Wire Scan­ner sys­tem. The ac­tu­a­tor con­sists of a ro­tary brushless syn­chronous motor with the per­ma­nent mag­net rotor in­stalled in­side the vac­u­um cham­ber and the sta­tor in­stalled out­side. The fork, per­ma­nent mag­net rotor and two an­gu­lar po­si­tion sen­sors are mount­ed on the same axis and lo­cat­ed in­side the beam vac­u­um cham­ber. The system has to re­sist a bake-out tem­per­a­ture of 200 C and ion­iz­ing radi­a­tion up to tenths of kGy/year. Max­i­mum wire trav­el­ling speed of 20 m/s and a po­si­tion mea­sure­ment ac­cu­ra­cy of 4 um is re­quired. Therefore, the sys­tem must avoid gen­er­at­ing vi­bra­tion and electromagnet­ic in­ter­fer­ence. A dig­i­tal feed­back con­troller will allow max­i­mum flex­i­bil­i­ty for the loop pa­ram­e­ters and feeds the 3-phase lin­ear power driv­er. The per­for­mance of the pr...

  16. Modeling the Effects of Beam Size and Flaw Morphology on Ultrasonic Pulse/Echo Sizing of Delaminations in Carbon Composites

    Science.gov (United States)

    Margetan, Frank J.; Leckey, Cara A.; Barnard, Dan

    2012-01-01

    The size and shape of a delamination in a multi-layered structure can be estimated in various ways from an ultrasonic pulse/echo image. For example the -6dB contours of measured response provide one simple estimate of the boundary. More sophisticated approaches can be imagined where one adjusts the proposed boundary to bring measured and predicted UT images into optimal agreement. Such approaches require suitable models of the inspection process. In this paper we explore issues pertaining to model-based size estimation for delaminations in carbon fiber reinforced laminates. In particular we consider the influence on sizing when the delamination is non-planar or partially transmitting in certain regions. Two models for predicting broadband sonic time-domain responses are considered: (1) a fast "simple" model using paraxial beam expansions and Kirchhoff and phase-screen approximations; and (2) the more exact (but computationally intensive) 3D elastodynamic finite integration technique (EFIT). Model-to-model and model-to experiment comparisons are made for delaminations in uniaxial composite plates, and the simple model is then used to critique the -6dB rule for delamination sizing.

  17. Electron beam generation and structure of defects in carbon and boron nitride nano-tubes

    Energy Technology Data Exchange (ETDEWEB)

    Zobelli, A

    2007-10-15

    The nature and role of defects is of primary importance to understand the physical properties of C and BN (boron nitride) single walled nano-tubes (SWNTs). Transmission electron microscopy (TEM) is a well known powerful tool to study the structure of defects in materials. However, in the case of SWNTs, the electron irradiation of the TEM may knock out atoms. This effect may alter the native structure of the tube, and has also been proposed as a potential tool for nano-engineering of nano-tubular structures. Here we develop a theoretical description of the irradiation mechanism. First, the anisotropy of the emission energy threshold is obtained via density functional based calculations. Then, we numerically derive the total Mott cross section for different emission sites of carbon and boron nitride nano-tubes with different chiralities. Using a dedicated STEM (Scanning Transmission Electron Microscope) microscope with experimental conditions optimised on the basis of derived cross-sections, we are able to control the generation of defects in nano-tubular systems. Either point or line defects can be obtained with a spatial resolution of a few nanometers. The structure, energetics and electronics of point and line defects in BN systems have been investigated. Stability of mono- and di- vacancy defects in hexagonal boron nitride layers is investigated, and their activation energies and reaction paths for diffusion have been derived using the nudged elastic band method (NEB) combined with density functional based techniques. We demonstrate that the appearance of extended linear defects under electron irradiation is more favorable than a random distribution of point defects and this is due to the existence of preferential sites for atom emission in the presence of pre-existing defects, rather than thermal vacancy nucleation and migration. (author)

  18. Carbon-ion beams effectively induce growth inhibition and apoptosis in human neural stem cells compared with glioblastoma A172 cells

    International Nuclear Information System (INIS)

    Carbon-ion radiotherapy (CIRT) holds promise in the treatment of glioblastoma, an aggressive X-ray–resistant brain tumor. However, since glioblastoma cells show a highly invasive nature, carbon-ion (C-ion) irradiation of normal tissues surrounding the tumor is inevitable. Recent studies have revealed the existence of neural stem cells in the adult brain. Therefore, the damaging effect of C-ion beams on the neural stem cells has to be carefully considered in the treatment planning of CIRT. Here, we investigated the growth and death mode of human neural stem cells (hNSCs) and glioblastoma A172 cells after X-ray or C-ion beam irradiation. The X-ray dose resulting in a 50% growth rate (D50) was 0.8 Gy in hNSCs and 3.0 Gy in A172 cells, while the D50 for C-ion beams was 0.4 Gy in hNSCs and 1.6 Gy in A172 cells; the relative biological effectiveness value of C-ion beams was 2.0 in hNSCs and 1.9 in A172 cells. Importantly, both X-rays and C-ion beams preferentially induced apoptosis, not necrosis, in hNSCs; however, radiation-induced apoptosis was less evident in A172 cells. The apoptosis-susceptible nature of the irradiated hNSCs was associated with prolonged upregulation of phosphorylated p53, whereas the apoptosis-resistant nature of A172 cells was associated with a high basal level of nuclear factor kappa B expression. Taken together, these data indicate that apoptosis is the major cell death pathway in hNSCs after irradiation. The high sensitivity of hNSCs to C-ion beams underscores the importance of careful target volume delineation in the treatment planning of CIRT for glioblastoma. (author)

  19. Improvement of spread-out Bragg peak flatness for a carbon-ion beam by the use of a ridge filter with a ripple filter.

    Science.gov (United States)

    Hara, Yousuke; Takada, Yoshihisa; Hotta, Kenji; Tansho, Ryohei; Nihei, Tetsuya; Suzuki, Yojiro; Nagafuchi, Kosuke; Kawai, Ryuichi; Tanabe, Masaki; Mizutani, Shohei; Himukai, Takeshi; Matsufuji, Naruhiro

    2012-03-21

    We have developed a novel design method of ridge filters for carbon-ion therapy using a broad-beam delivery system to improve the flatness of a biologically effective dose in the spread-out Bragg peak (SOBP). So far, the flatness of the SOBP is limited to about ±5% for carbon beams since the weight control of component Bragg curves composing the SOBP is difficult. This difficulty arises from using a large number of ridge-bar steps (e.g. about 100 for a SOBP width of 60 mm) required to form the SOBP for the pristine Bragg curve with an extremely sharp distal falloff. Instead of using a single ridge filter, we introduce a ripple filter to broaden the Bragg peak so that the number of ridge-bar steps can be reduced to about 30 for SOBP with of 60 mm for the ridge filter designed for the broadened Bragg peak. Thus we can manufacture the ridge filter more accurately and then attain a better flatness of the SOBP due to well-controlled weights of the component Bragg curves. We placed the ripple filter on the same frame of the ridge filter and arranged the direction of the ripple-filter-bar array perpendicular to that of the ridge-filter-bar array. We applied this method to a 290 MeV u(-1) carbon-ion beam in Heavy Ion Medical Accelerator in Chiba and verified the effectiveness by measurements.

  20. Mycosis fungoides. Electron beam therapy.

    Science.gov (United States)

    Spittle, M F

    1977-01-01

    The most effective treatment of late mycosis fungoides is total skin electron beam therapy. The beam at the Hammersmith Hospital in London has been adapted to treat these patients. Patients with advanced disease who have failed more conservative methods of treatment are irradiated. The electron beam is modified by the use of carbon and copper scatterers to produce an 80 percent depth dose at 5.5, 8 and 11.5 millimeters below the skin surface. The dose achieved in most patients is between 1500 rads and 2600 rads given in 10 to 13 treatments over 5-7 weeks. Recently the higher dose range has been employed and lithium flouride studies have shown that giving these doses from each of 4 fields, the dose achieved on the skin is approximately twice the given dose. The management of patients and the effects of treatment are discussed.

  1. Protective Sliding Carbon-Based Nanolayers Prepared by Argon or Nitrogen Ion-Beam Assisted Deposition on Ti6Al4V Alloy

    Directory of Open Access Journals (Sweden)

    Petr Vlcak

    2016-01-01

    Full Text Available The microstructure and the surface properties of samples coated by carbon-based nanolayer were investigated in an effort to increase the surface hardness and reduce the coefficient of friction of the Ti6Al4V alloy. Protective carbon-based nanolayers were fabricated by argon or nitrogen ion-beam assisted deposition at ion energy of 700 eV on Ti6Al4V substrates. The Raman spectra indicated that nanolayers had a diamond-like carbon character with sp2 rich bonds. The TiC and TiN compounds formed in the surface area were detected by X-ray diffraction. Nanoscratch tests showed increased adhesion of a carbon-based nanolayer deposited with ion assistance in comparison with a carbon nanolayer deposited without ion assistance. The results showed that argon ion assistance leads to greater nanohardness than a sample coated by a carbon-based nanolayer with nitrogen ion assistance. A more than twofold increase in nanohardness and a more than fivefold decrease in the coefficient of friction were obtained for samples coated by a carbon-based nanolayer with ion assistance, in comparison with the reference sample.

  2. Laboratory measurement of the 2-centimeter, 2/11/-2/12/ transition of normal formaldehyde and its carbon-13 and oxygen-18 species.

    Science.gov (United States)

    Tucker, K. D.; Tomasevich, G. R.; Thaddeus, P.

    1972-01-01

    Beam-maser spectrometric measurements to an accuracy of about 100 Hz have been conducted of the 2(11)-2(12) transition for the isotopic species of greatest astronomical interest - i.e., H2CO, H2(13)CO, and H2C(18)O. The samples used were not isotopically enriched, monomeric formaldehyde vapors. For these species, all the coupling constants required to calculate the hyperfine structure of any rotational transition have been determined.

  3. Assembly and Electrochemical Study of Transition Metal Substituted Polyoxometalates SiW11NiO6-39 and SiW11MnO6-39 on 4-Aminothiophenol Modified Glassy Carbon Electrode

    Institute of Scientific and Technical Information of China (English)

    L(U¨) Gui-qin; DU Jin-yan; HU Chang-wen

    2005-01-01

    Via layer-by-layer assembly, the polyoxometalates of Keggin type, SiW11O39Ni(H2O)6-(SiNiW11) and SiW11O39Mn(H2O)6-(SiMnW11) were first immobilized on a 4-aminothiophenol(4-ATP) modified glassy carbon electrode surface. The electrochemical behavior of these polyoxometalates was investigated. They exhibited some special properties in the films, which are different from those in a homogeneous aqueous solution. Their reaction mechanism in a multilayer film is proposed. The electrocatalytic behavior of these multilayer film electrodes for the reduction of BrO-3 and NO-2 were comparatively studied.

  4. Four-dimensional layer-stacking carbon-ion beam dose distribution by use of a lung numeric phantom.

    Science.gov (United States)

    Mori, Shinichiro; Kumagai, Motoki; Miki, Kentaro

    2015-07-01

    To extend layer-stacking irradiation to accommodate intrafractional organ motion, we evaluated the carbon-ion layer-stacking dose distribution using a numeric lung phantom. We designed several types of range compensators. The planning target volume was calculated from the respective respiratory phases for consideration of intrafractional beam range variation. The accumulated dose distribution was calculated by registering of the dose distributions at respective phases to that at the reference phase. We evaluated the dose distribution based on the following six parameters: motion displacement, direction, gating window, respiratory cycle, range-shifter change time, and prescribed dose. All parameters affected the dose conformation to the moving target. By shortening of the gating window, dose metrics for superior-inferior (SI) and anterior-posterior (AP) motions were decreased from a D95 of 94 %, Dmax of 108 %, and homogeneity index (HI) of 23 % at T00-T90, to a D95 of 93 %, Dmax of 102 %, and HI of 20 % at T40-T60. In contrast, all dose metrics except the HI were independent of respiratory cycle. All dose metrics in SI motion were almost the same in respective motion displacement, with a D95 of 94 %, Dmax of 108 %, Dmin of 89 %, and HI of 23 % for the ungated phase, and D95 of 93 %, Dmax of 102 %, Dmin of 85 %, and HI of 20 % for the gated phase. The dose conformation to a moving target was improved by the gating strategy and by an increase in the prescribed dose. A combination of these approaches is a practical means of adding them to existing treatment protocols without modifications.

  5. Simple synthesis of carbon-11-labeled chromen-4-one derivatives as new potential PET agents for imaging of DNA-dependent protein kinase (DNA-PK) in cancer

    International Nuclear Information System (INIS)

    Carbon-11-labeled chromen-4-one derivatives were synthesized as new potential PET agents for imaging of DNA repair enzyme DNA-dependent protein kinase (DNA-PK) in cancer. The target tracers, X-[11C]methoxy-2-morpholino-4H-chromen-4-ones (X=8, 7, 6, 5; [11C]4a–d), were prepared from their corresponding precursors, X-hydroxy-2-morpholino-4H-chromen-4-ones (X=8, 7, 6, 5; 5a–d), with [11C]CH3OTf through O-[11C]methylation and isolated by a simplified solid-phase extraction (SPE) method using a C-18 Sep-Pak Plus cartridge. The radiochemical yields decay corrected to end of bombardment (EOB), from [11C]CO2, were 40–60%. The specific activity at end of synthesis (EOS) was 185–370 GBq/μmol. - Highlights: ► New chromen-4-one derivatives were synthesized. ► New carbon-11-labeled chromen-4-one derivatives were synthesized. ► Simple solid-phase extraction (SPE) method was employed in radiosynthesis.

  6. Whole-body pharmacokinetics of HDAC inhibitor drugs, butyric acid, valproic acid and 4-phenylbutyric acid measured with carbon-11 labeled analogs by PET

    International Nuclear Information System (INIS)

    The fatty acids, n-butyric acid (BA), 4-phenylbutyric acid (PBA) and valproic acid (VPA, 2-propylpentanoic acid) have been used for many years in the treatment of a variety of CNS and peripheral organ diseases including cancer. New information that these drugs alter epigenetic processes through their inhibition of histone deacetylases (HDACs) has renewed interest in their biodistribution and pharmacokinetics and the relationship of these properties to their therapeutic and side effect profiles. In order to determine the pharmacokinetics and biodistribution of these drugs in primates, we synthesized their carbon-11 labeled analogues and performed dynamic positron emission tomography (PET) in six female baboons over 90 min. The carbon-11 labeled carboxylic acids were prepared by using 11CO2 and the appropriate Grignard reagents. [11C]BA was metabolized rapidly (only 20% of the total carbon-11 in plasma was parent compound at 5 min post injection) whereas for VPA and PBA 98% and 85% of the radioactivity were the unmetabolized compound at 30 min after their administration respectively. The brain uptake of all three carboxylic acids was very low ( VPA > PBA), which is consistent with the need for very high doses for therapeutic efficacy. Most of the radioactivity was excreted through the kidneys and accumulated in the bladder. However, the organ biodistribution between the drugs differed. [11C]BA showed relatively high uptake in spleen and pancreas whereas [11C]PBA showed high uptake in liver and heart. Notably, [11C]VPA showed exceptionally high heart uptake possibly due to its involvement in lipid metabolism. The unique biodistribution of each of these drugs may be of relevance in understanding their therapeutic and side effect profile including their teratogenic effects

  7. Partial pressure (or fugacity) of carbon dioxide, salinity and other variables collected from time series observations using Bubble type equilibrator for autonomous carbon dioxide (CO2) measurement, Carbon dioxide (CO2) gas analyzer and other instruments from the MOORINGS in the North Pacific Ocean from 2008-11-11 to 2010-10-11 (NODC Accession 0084098)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NODC Accession 0084098 includes chemical, physical and time series data collected from MOORINGS in the North Pacific Ocean from 2008-11-11 to 2010-10-11. These data...

  8. Properties of carbon-based structures synthesized in nuclear reactions induced by bremsstrahlung γ quanta with threshold energy of 10 MeV at helium pressure of 1.1 kbar

    Science.gov (United States)

    Didyk, A. Yu.; Wiśniewski, R.

    2016-07-01

    Helium gas with an initial pressure of about 1.1 kbar inside a high-pressure chamber (HeHPC) has been irradiated by bremsstrahlung γ quanta with a threshold energy of 10 MeV for 1.0 × 105 s produced by an electron-beam current of 22-24 μA. After opening the HeHPC, the residual pressure of helium is equal to 430 bar. Synthesized black foils with a variety of other objects are found inside the HeHPC. They are located on the inner surfaces of the reaction chamber made of high-purity copper (99.99%), the entrance the window of γ quanta made of beryllium bronze and a copper container of nuclear and chemical reaction products. Elemental analysis with the use of scanning electron microscopy and X-ray microprobe analysis has revealed that the foils contain predominantly carbon and small quantities of other elements from carbon to iron. The results are in good agreement with the cycle of investigations of the authors devoted to the γ-quanta irradiation of dense hydrogen and helium gases in the presence (absence) of metals in a reaction chamber.

  9. The effects of carbon foil on beams in stripping-accumulation of a heavy-ion synchrotron

    International Nuclear Information System (INIS)

    Stripping-injection scheme is adopted in the synchrotron of an accelerator complex named as HITFiL. HITFIL is dedicated to cancer therapy. High intensity can be reached by using the stripping-injection as the limit of Liouville's theorem is broken due to charge-exchange. But unavoidable traversals of the circulating beams through the foil may cause beam-losses and deteriorations of beam quality, including: 1) beam-losses caused by an alteration of the particles' charge state; 2) emittance growth caused by Multiple Coulomb Scattering; and 3) decrease of mean-momentum and growth of momentum spread induced by energy loss and energy loss straggling. In this paper, the model of particle-foil interaction is established by Monte Carlo processes. The effects of the stripping foil on beams are studied based on an improvement of the ACCSIM code. (authors)

  10. Effects of heat treatment on the corrosion resistance of carbon steel coated with LaMgAl11O19 thermal barrier coatings

    Science.gov (United States)

    Huang, Liang-liang; Meng, Hui-min; Liang, Li-kang; Li, Sen; Shi, Jin-hui

    2015-10-01

    LaMgAl11O19 thermal barrier coatings (TBCs) were applied to carbon steels with a NiCoCrAlY bond coat by plasma spraying. The effects of heat treatment on the corrosion resistance of carbon steel coated with LaMgAl11O19 TBCs were investigated in 3.5wt% NaCl solution using polarization curves, electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM), and X-ray diffraction (XRD). The results show that a large number of cracks are found in the LaMgAl11O19 TBCs after the samples are heat-treated, including some through-thickness cracks. The corrosion forms of the as-sprayed and heat-treated TBCs are uniform corrosion and pitting corrosion, respectively. The as-sprayed TBCs exhibit three EIS time constants after being immersed for less than 7 d, and then a new time constant appears because of steel substrate corrosion. When the immersion time is increased to 56 d, a Warburg impedance ( W) component appears in the EIS data. The EIS data for the heat-treated TBCs exhibit only two time constants after the samples are immersed for less than 14 d, and a new time constant appears when the immersion time is increased further. The heat treatment reduces the corrosion resistance of carbon steel coated with LaMgAl11O19 TBCs. The corrosion products are primarily γ-FeOOH and Fe3O4.

  11. ANSYS simulation study on displacement of carbon fiber reinforced concrete beam%碳纤维加固混凝土梁位移ANSYS模拟研究

    Institute of Scientific and Technical Information of China (English)

    王良超; 杨治华; 刘敏

    2012-01-01

    For beam mid-span displacement, theoretical calculation and ANSYS modeling computational analysis have been done to quantitative analysis of the effect of carbon fiber reinforcement beam, and improve the further relevant reinforcement theory, to provide a theoretical and com- putational support for real-strengthening works. The analysis shows that the values and trends of finite element analysis and theoretical calculations are very similar, which indicates that the finite element analysis is capable to simulate the beam actual stress state, the displacement of FRP rein- forced beam decreases 14.08%.%针对梁体跨中位移,通过理论计算以及ANSYS建模分析计算分析比较,定量分析碳纤维加固梁体的效果,进一步完善相关加固理论,为现实加固工程提供理论和计算支持,分析表明,有限元分析计算值和理论计算值在数值和发展趋势上都有很大的相似性,说明有限元分析能较好的模拟梁体实际受力状态,FRP加固后梁体位移减小14.08%。

  12. Air-tolerant Fabrication and Enhanced Thermoelectric Performance of n-Type Single-walled Carbon Nanotubes Encapsulating 1,1'-Bis(diphenylphosphino)ferrocene.

    Science.gov (United States)

    Nonoguchi, Yoshiyuki; Iihara, Yu; Ohashi, Kenji; Murayama, Tomoko; Kawai, Tsuyoshi

    2016-09-01

    The thermally-triggered n-type doping of single-walled carbon nanotubes is demonstrated using 1,1'-bis(diphenylphosphino)ferrocene, a novel n-type dopant. Through a simple thermal vacuum process, the phosphine compounds are moderately encapsulated inside single-walled carbon nanotubes. The encapsulation into SWNTs is carefully characterized using Raman/X-ray spectroscopy and transmission electron microscopy. This easy-to-handle doping with air-stable precursors for n-type SWNTs enables the large-scale fabrication of thermoelectric materials showing an excellent power factor exceeding approximately 240 μW mK(-2) .

  13. Low-dose patterning of platinum nanoclusters on carbon nanotubes by focused-electron-beam-induced deposition as studied by TEM

    Directory of Open Access Journals (Sweden)

    Xiaoxing Ke

    2013-02-01

    Full Text Available Focused-electron-beam-induced deposition (FEBID is used as a direct-write approach to decorate ultrasmall Pt nanoclusters on carbon nanotubes at selected sites in a straightforward maskless manner. The as-deposited nanostructures are studied by transmission electron microscopy (TEM in 2D and 3D, demonstrating that the Pt nanoclusters are well-dispersed, covering the selected areas of the CNT surface completely. The ability of FEBID to graft nanoclusters on multiple sides, through an electron-transparent target within one step, is unique as a physical deposition method. Using high-resolution TEM we have shown that the CNT structure can be well preserved thanks to the low dose used in FEBID. By tuning the electron-beam parameters, the density and distribution of the nanoclusters can be controlled. The purity of as-deposited nanoclusters can be improved by low-energy electron irradiation at room temperature.

  14. The potential of carbon-11 and fluorine-18 chemistry: illustration through the development of positron emission tomography radioligands targeting the translocator protein 18 kDa

    International Nuclear Information System (INIS)

    The TSPO (translocator protein), also known as the peripheral benzodiazepine receptor, is up-regulated in the brain of subjects suffering from neuro-degenerative disorders such as Alzheimer's, Parkinson's and Huntington's disease. Moreover, this overexpression has been proved to be linked to micro-glia activation making thus the TSPO a marker of choice of neuro-inflammatory processes and therefore a potential target for the development of radioligands for positron emission tomography imaging. The discovery of selective TSPO ligands and their labelling with the short-lived positron-emitter isotopes carbon-11 and fluorine-18 emerged in the mid-1980's with the preparation of the 3-iso-quinolinecarboxamide [11C]PK11195. To date, an impressive number of promising compounds - [11C]PK11195-challengers - have been developed; some radioligands - for example, [11C]PBR28, [11C]DPA-713, [18F]FEDAA1106 and [18F]DPA-714 - are currently used in clinical trials. As illustrated in this review, the methodologies applied for the preparation of these compounds remain mainly [11C]methylations using [11C]MeI or [11C]MeOTf and SN2- type nucleophilic aliphatic [18F]fluorinations - two processes illustrating the state-of-the-art arsenal of reactions that involves these two short-lived radioisotopes - but alternative processes, such as [11C]carbonylations using [11C]CO and [11C]COCl2 as well as SNAr-type nucleophilic [18F]fluorinations, have also been reported and as such, reviewed herein. (authors)

  15. Effects of beam interruption time on tumor control probability in single-fractionated carbon-ion radiotherapy for non-small cell lung cancer

    International Nuclear Information System (INIS)

    Carbon-ion radiotherapy treatment plans are designed on the assumption that the beams are delivered instantaneously, irrespective of actual dose-delivery time structure in a treatment session. As the beam lines are fixed in the vertical and horizontal directions at our facility, beam delivery is interrupted in multi-field treatment due to the necessity of patient repositioning within the fields. Single-fractionated treatment for non-small cell lung cancer (NSCLC) is such a case, in which four treatment fields in multiple directions are delivered in one session with patient repositioning during the session. The purpose of this study was to investigate the effects of the period of dose delivery, including interruptions due to patient repositioning, on tumor control probability (TCP) of NSCLC. All clinical doses were weighted by relative biological effectiveness (RBE) evaluated for instantaneous irradiation. The rate equations defined in the microdosimetric kinetic model (MKM) for primary lesions induced in DNA were applied to the single-fractionated treatment of NSCLC. Treatment plans were made for an NSCLC case for various prescribed doses ranging from 25 to 50 Gy (RBE), on the assumption of instantaneous beam delivery. These plans were recalculated by varying the interruption time τ ranging from 0 to 120 min between the second and third fields for continuous irradiations of 3 min per field based on the MKM. The curative doses that would result in a TCP of 90% were deduced for the respective interruption times. The curative dose was 34.5 Gy (RBE) for instantaneous irradiation and 36.6 Gy (RBE), 39.2 Gy (RBE), 41.2 Gy (RBE), 43.3 Gy (RBE) and 44.4 Gy (RBE) for τ = 0 min, 15 min, 30 min, 60 min and 120 min, respectively. The realistic biological effectiveness of therapeutic carbon-ion beam decreased with increasing interruption time. These data suggest that the curative dose can increase by 20% or more compared to the planned dose if

  16. Effects of beam interruption time on tumor control probability in single-fractionated carbon-ion radiotherapy for non-small cell lung cancer

    Science.gov (United States)

    Inaniwa, T.; Kanematsu, N.; Suzuki, M.; Hawkins, R. B.

    2015-05-01

    Carbon-ion radiotherapy treatment plans are designed on the assumption that the beams are delivered instantaneously, irrespective of actual dose-delivery time structure in a treatment session. As the beam lines are fixed in the vertical and horizontal directions at our facility, beam delivery is interrupted in multi-field treatment due to the necessity of patient repositioning within the fields. Single-fractionated treatment for non-small cell lung cancer (NSCLC) is such a case, in which four treatment fields in multiple directions are delivered in one session with patient repositioning during the session. The purpose of this study was to investigate the effects of the period of dose delivery, including interruptions due to patient repositioning, on tumor control probability (TCP) of NSCLC. All clinical doses were weighted by relative biological effectiveness (RBE) evaluated for instantaneous irradiation. The rate equations defined in the microdosimetric kinetic model (MKM) for primary lesions induced in DNA were applied to the single-fractionated treatment of NSCLC. Treatment plans were made for an NSCLC case for various prescribed doses ranging from 25 to 50 Gy (RBE), on the assumption of instantaneous beam delivery. These plans were recalculated by varying the interruption time τ ranging from 0 to 120 min between the second and third fields for continuous irradiations of 3 min per field based on the MKM. The curative doses that would result in a TCP of 90% were deduced for the respective interruption times. The curative dose was 34.5 Gy (RBE) for instantaneous irradiation and 36.6 Gy (RBE), 39.2 Gy (RBE), 41.2 Gy (RBE), 43.3 Gy (RBE) and 44.4 Gy (RBE) for τ = 0 min, 15 min, 30 min, 60 min and 120 min, respectively. The realistic biological effectiveness of therapeutic carbon-ion beam decreased with increasing interruption time. These data suggest that the curative dose can increase by 20% or more compared to the planned dose if the

  17. USGS Arctic Ocean carbon cruise 2011: field activity H-01-11-AR to collect carbon data in the Arctic Ocean, August - September 2011

    Science.gov (United States)

    Robbins, Lisa L.; Yates, Kimberly K.; Knorr, Paul O.; Wynn, Jonathan; Lisle, John; Buczkowski, Brian J.; Moore, Barbara; Mayer, Larry; Armstrong, Andrew; Byrne, Robert H.; Liu, Xuewu

    2013-01-01

    Carbon dioxide (CO2) in the atmosphere is absorbed at the surface of the ocean by reacting with seawater to form a weak, naturally occurring acid called carbonic acid. As atmospheric carbon dioxide increases, the concentration of carbonic acid in seawater also increases, causing a decrease in ocean pH and carbonate mineral saturation states, a process known as ocean acidification. The oceans have absorbed approximately 525 billion tons of carbon dioxide from the atmosphere, or about one-quarter to one-third of the anthropogenic carbon emissions released since the beginning of the Industrial Revolution (Sabine and others, 2004). Global surveys of ocean chemistry have revealed that seawater pH has decreased by about 0.1 units (from a pH of 8.2 to 8.1) since the 1700s due to absorption of carbon dioxide (Caldeira and Wickett, 2003; Orr and others, 2005; Raven and others, 2005). Modeling studies, based on Intergovernmental Panel on Climate Change (IPCC) CO2 emission scenarios, predict that atmospheric carbon dioxide levels could reach more than 500 parts per million (ppm) by the middle of this century and 800 ppm by the year 2100, causing an additional decrease in surface water pH of 0.3 pH units. Ocean acidification is a global threat and is already having profound and deleterious effects on the geology, biology, chemistry, and socioeconomic resources of coastal and marine habitats (Raven and others, 2005; Ruttiman, 2006). The polar and sub-polar seas have been identified as the bellwethers for global ocean acidification.

  18. Measurement of fragment production DDX of 72 and 144 MeV 12C beam induced reaction on carbon using Bragg Curve Counter

    International Nuclear Information System (INIS)

    Double differential cross section (DDX) data of fragment production for 72 (6 MeV/nucleon) and 144 MeV (12 MeV/nucleon) 12C beam induced reaction on carbon were measured using a Bragg Curve Counter (BCC). The DDX data were obtained for fragments of He, Li, Be, B, C, N and O at 30 degree emission angle. Theoretical calculation using PHITS code with QMD+GEM model represents the DDX well except for components from reactions of direct process and α particle clustering process. (author)

  19. Properties of carbon beams for radiotherapy with three different energies: 135 MeV/u, 290 MeV/u and 400 MeV/u

    International Nuclear Information System (INIS)

    Sets of plastic nuclear track detectors, used as spectrometers of linear energy transfer (LET), were exposed to carbon beams at 3 different initial energy levels (135, 290, and 400 MeV/u) obtained from the HIMAC accelerator (NIRS, Chiba, Japan). The detectors were positioned behind PMMA filters of different thickness chosen so as to cover whole area of the Bragg curve. The LET spectra were measured and the dependences of the absorbed dose and other biological weighted factors on the depth were estimated. (orig.)

  20. Measurement of analyzing power for proton-carbon elastic scattering in the coulomb-nuclear interference region with a 22-GeV/c polarized proton beam.

    Science.gov (United States)

    Tojo, J; Alekseev, I; Bai, M; Bassalleck, B; Bunce, G; Deshpande, A; Doskow, J; Eilerts, S; Fields, D E; Goto, Y; Huang, H; Hughes, V; Imai, K; Ishihara, M; Kanavets, V; Kurita, K; Kwiatkowski, K; Lewis, B; Lozowski, W; Makdisi, Y; Meyer, H-O; Morozov, B V; Nakamura, M; Przewoski, B; Rinckel, T; Roser, T; Rusek, A; Saito, N; Smith, B; Svirida, D; Syphers, M; Taketani, A; Thomas, T L; Underwood, D; Wolfe, D; Yamamoto, K; Zhu, L

    2002-07-29

    The analyzing power for proton-carbon elastic scattering in the Coulomb-nuclear interference region of momentum transfer, 9.0x10(-3)<-t<4.1x10(-2) (GeV/c)(2), was measured with a 21.7 GeV/c polarized proton beam at the Alternating Gradient Synchrotron of Brookhaven National Laboratory. The ratio of hadronic spin-flip to nonflip amplitude, r(5), was obtained from the analyzing power to be Rer(5)=0.088+/-0.058 and Imr(5)=-0.161+/-0.226. PMID:12144435

  1. Measurement of analyzing power for proton-carbon elastic scattering in the Coulomb-nuclear interference region with a 22-GeV/c polarized proton beam

    International Nuclear Information System (INIS)

    The analyzing power for proton-carbon elastic scattering in the Coulomb-nuclear interference region of momentum transfer, 9.0x10-3-2 (GeV/c)2, was measured with a 21.7 GeV/c polarized proton beam at the Alternating Gradient Synchrotron of Brookhaven National Laboratory. The ratio of hadronic spin-flip to nonflip amplitude, r5, was obtained from the analyzing power to be Rer5=0.088±0.058 and Imr5=-0.161±0.226

  2. Measurement of Neutral Current Neutral Pion Production on Carbon in a Few-GeV Neutrino Beam

    Energy Technology Data Exchange (ETDEWEB)

    Kurimoto, Yoshinori [Kyoto Univ. (Japan)

    2010-01-01

    Understanding of the π0 production via neutrino-nucleus neutral current interaction in the neutrino energy region of a few GeV is essential for the neutrino oscillation experiments. In this thesis, we present a study of neutral current π0 production from muon neutrinos scattering on a polystyrene (C8H8) target in the SciBooNE experiment. All neutrino beam data corresponding to 0.99 × 1020 protons on target have been analyzed. We have measured the cross section ratio of the neutral current π0 production to the total charge current interaction and the π0 kinematic distribution such as momentum and direction. We obtain [7.7 ± 0.5(stat.) ± 0.5(sys.)] × 10-2 as the ratio of the neutral current neutral pion production to total charged current cross section; the mean energy of neutrinos producing detected neutral pions is 1.1 GeV. The result agrees with the Rein- Sehgal model, which is generally used for the Monte Carlo simulation by many neutrino oscillation experiments. We achieve less than 10 % uncertainty which is required for the next generation search for νµ → νe oscillation. The spectrum shape of the π0 momentum and the distribution of the π0 emitted angle agree with the prediction, which means that not only the Rein-Sehgal model but also the intra-nuclear interaction models describe our data well. We also measure the ratio of the neutral current coherent pion production to total charged current cross section to be (1.17 ± 0.23 ) × 10-2 based on the Rein and Sehgal model. The result gives the evidence for non-zero coherent pion production via neutral current interaction at the mean neutrino energy of 1.0 GeV.

  3. Beam-beam effects

    Energy Technology Data Exchange (ETDEWEB)

    Zholents, A.

    1994-12-01

    The term beam-beam effects is usually used to designate different phenomena associated with interactions of counter-rotating beams in storage rings. Typically, the authors speak about beam-beam effects when such interactions lead to an increase of the beam core size or to a reduction of the beam lifetime or to a growth of particle`s population in the beam halo and a correspondent increase of the background. Although observations of beam-beam effects are very similar in most storage rings, it is very likely that every particular case is largely unique and machine-dependent. This constitutes one of the problems in studying the beam-beam effects, because the experimental results are often obtained without characterizing a machine at the time of the experiment. Such machine parameters as a dynamic aperture, tune dependencies on amplitude of particle oscillations and energy, betatron phase advance between the interaction points and some others are not well known, thus making later analysis uncertain. The authors begin their discussion with demonstrations that beam-beam effects are closely related to non linear resonances. Then, they will show that a non linearity of the space charge field is responsible for the excitation of these resonances. After that, they will consider how beam-beam effects could be intensified by machine imperfections. Then, they will discuss a leading mechanism for the formation of the beam halo and will describe a new technique for beam tails and lifetime simulations. They will finish with a brief discussion of the coherent beam-beam effects.

  4. pi deg. and eta photoproduction on the proton at GRAAL: New measurements of beam asymmetry up to 1.5 GeV and differential cross-section up to 1.1 GeV

    CERN Document Server

    Rebreyend, D

    2000-01-01

    After the achievement of the first beam asymmetry (SIGMA) measurement in eta photoproduction on the proton from threshold to 1.1 GeV [1], the energy range of the GRAAL facility has been extended to 1.5 GeV. New results of SIGMA for both pi deg. and eta, covering this new domain will be presented. Also, the differential cross-section for pi deg. and eta channels will be shown for energies up to 1.1 GeV.

  5. Development of additive [{sup 11}C]CO{sub 2} target system in the KOTRON-13 cyclotron and its application for [{sup 11}C]radiopharmaceutical production

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Byung Seok; Lee, Hong Jin [Department of Nuclear Medicine, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam 463-707 (Korea, Republic of); Lee, Won Kyung [Technical Support Team, Duchembio, Seoul 121-844 (Korea, Republic of); Hur, Min Goo; Yang, Seung Dae [Radiation Instrumentation Research Division, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of); Lee, Byung Chul, E-mail: leebc2001@gmail.com [Department of Nuclear Medicine, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam 463-707 (Korea, Republic of); Center for Nanomolecular Imaging and Innovative Drug Development, Advanced Institutes of Convergence Technology, Suwon 443-270 (Korea, Republic of); Kim, Sang Eun [Department of Nuclear Medicine, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam 463-707 (Korea, Republic of); Center for Nanomolecular Imaging and Innovative Drug Development, Advanced Institutes of Convergence Technology, Suwon 443-270 (Korea, Republic of); Smart Humanity Convergence Center, Graduate School of Convergence Science and Technology, Seoul National University, Seoul 443-270 (Korea, Republic of)

    2015-08-01

    The KOTRON-13 cyclotron, which was developed in South Korea for the production of medical radioisotopes, has the structural limitation of only one beam-output port, restricting the production of the carbon-11 isotope. In the present study, we investigate the design of a switchable target system and develop an effective carbon-11 target in the KOTRON-13 cyclotron, for combination with the fluorine-18 target. The target system was designed by introducing a sliding-type element between the fluorine-18 and carbon-11 targets, a tailor-made C-11 target and its cooling system. For the efficient production of [{sup 11}C]CO{sub 2}, the desirable target shape and internal volume were determined by a Stopping and Range of Ions in Matter (SRIM) simulation program, and the target grid was modified to resist the cavity pressure during beam irradiation. We evaluated the [{sup 11}C]CO{sub 2} production while varying the material and thickness of the target foil, oxygen content of the nitrogen gas, and target loading pressure. Using sliding-type equipment including an additional gate valve and a high vacuum in a beam line, the bi-directional conversion between the fluorine-18 and carbon-11 targets was efficient regarding the accurate beam irradiation on both targets. The optimal [{sup 11}C]CO{sub 2} production for 30 min irradiation at 60 μA (86.6 ± 1.7 GBq in the target at EOB) was observed at a thickness of 19 μm with HAVAR® material as a target foil and a target loading pressure of 24 bar with nitrogen plus 300 ppb of oxygen gas. Additionally, the coolant cavity system in the target grid and target chamber is useful to remove the heat transferred to the target body by the internal convection of water and thereby ensure the stability of the [{sup 11}C]CO{sub 2} production under a high beam current. In the application of C-11 labeled radiopharmaceuticals such as [{sup 11}C]PIB, [{sup 11}C]DASB, [{sup 11}C]PBR28, [{sup 11}C]Methionine and [{sup 11}C]Clozapine, the radiochemical

  6. Development of additive [11C]CO2 target system in the KOTRON-13 cyclotron and its application for [11C]radiopharmaceutical production

    International Nuclear Information System (INIS)

    The KOTRON-13 cyclotron, which was developed in South Korea for the production of medical radioisotopes, has the structural limitation of only one beam-output port, restricting the production of the carbon-11 isotope. In the present study, we investigate the design of a switchable target system and develop an effective carbon-11 target in the KOTRON-13 cyclotron, for combination with the fluorine-18 target. The target system was designed by introducing a sliding-type element between the fluorine-18 and carbon-11 targets, a tailor-made C-11 target and its cooling system. For the efficient production of [11C]CO2, the desirable target shape and internal volume were determined by a Stopping and Range of Ions in Matter (SRIM) simulation program, and the target grid was modified to resist the cavity pressure during beam irradiation. We evaluated the [11C]CO2 production while varying the material and thickness of the target foil, oxygen content of the nitrogen gas, and target loading pressure. Using sliding-type equipment including an additional gate valve and a high vacuum in a beam line, the bi-directional conversion between the fluorine-18 and carbon-11 targets was efficient regarding the accurate beam irradiation on both targets. The optimal [11C]CO2 production for 30 min irradiation at 60 μA (86.6 ± 1.7 GBq in the target at EOB) was observed at a thickness of 19 μm with HAVAR® material as a target foil and a target loading pressure of 24 bar with nitrogen plus 300 ppb of oxygen gas. Additionally, the coolant cavity system in the target grid and target chamber is useful to remove the heat transferred to the target body by the internal convection of water and thereby ensure the stability of the [11C]CO2 production under a high beam current. In the application of C-11 labeled radiopharmaceuticals such as [11C]PIB, [11C]DASB, [11C]PBR28, [11C]Methionine and [11C]Clozapine, the radiochemical yields were shown to be 25–38% (decay corrected) with over 166 GBq/μmol of

  7. Diallyl disulfide enhances carbon ion beams-induced apoptotic cell death in cervical cancer cells through regulating Tap73 /ΔNp73.

    Science.gov (United States)

    Di, Cuixia; Sun, Chao; Li, Hongyan; Si, Jing; Zhang, Hong; Han, Lu; Zhao, Qiuyue; Liu, Yang; Liu, Bin; Miao, Guoying; Gan, Lu; Liu, Yuanyuan

    2015-01-01

    Diallyl disulfide (DADS), extracted from crushed garlic by steam-distillation, has been reported to provide the anticancer activity in several cancer types. However, the effect of DADS on high-LET carbon beams - induced cell death remains unknown. Therefore, we used human cervical cancer cells to elucidate the molecular effects of this diallyl sulfide. Radiotherapy remains the mainstay of treatment, especially in advanced cervical cancer and there is still space to improve the radiosensitivity to reduce radiation dosage. In this study, we found that radiation effects evoked by high-LET carbon beam was marked by inhibition of cell viability, cell cycle arrest, significant rise of apoptotic cells, regulation of transcription factor, such as p73, as well as alterations of crucial mediator of the apoptosis pathway. We further demonstrated that pretreatment of 10 µM DADS in HeLa cells exposed to radiation resulted in decrease in cell viability and increased radiosensitivity. Additionally, cells pretreated with DADS obviously inhibited the radiation-induced G2/M phase arrest, but promoted radiation-induced apoptosis. Moreover, combination DADS and the radiation exacerbated the activation of apoptosis pathways through up-regulated ration of pro-apoptotic Tap73 to anti-apoptotic ΔNp73, and its downstream proteins, such as FASLG, and APAF1. Taken together, these results suggest that DADS is a potential candidate as radio sensitive agent for cervical cancer. PMID:26505313

  8. Effect of electron beam irradiation on multi-walled carbon nanotubes%电子束辐照对多壁碳纳米管的影响

    Institute of Scientific and Technical Information of China (English)

    李斌; 凤仪; 丁克望; 钱刚; 张学斌; 刘衍芳

    2014-01-01

    在室温下采用透射电子显微镜中汇聚的电子束辐照多壁碳纳米管。结果表明,在能量为100 keV的电子束辐照下除了碳纳米管管壁有一些弯曲外没有其他结构被破坏;当电子能量增加到200 keV时,纳米管有明显的损伤,可以观察到纳米管的无定型化、纳米管外壁的凹坑和缺口。200 keV的电子束辐照还能形成碳洋葱和2根多壁纳米管的焊接。多壁碳纳米管的离位阀能为83~110 keV。能量超过阀能的电子束可以很轻易地损伤纳米管而低于阀能的电子束则很难损坏纳米管,其损伤机理为溅射和原子离位。%Multi-walled carbon nanotubes (MWCNTs) were irradiated with focused electron beams in a transmission electron microscope at room temperature. The results showed that carbon nanotubes had no obvious structural damages but only shell bending under 100 keV electron beam irradiation. However, when the electron energy increased to 200 keV, the nanotubes were damaged and amorphization, pits and gaps were detected. Furthermore, generating of carbon onions and welding between two MWCNTs occurred under 200 keV electron irradiation. It was easy to destroy the MWCNTs as the electron beams exceeded the displacement threshold energy that was calculated to be 83-110 keV. Conversely, the energy of electron beams below the threshold energy was not able to damage the tubes. The damage mechanism is sputtering and atom displacement.

  9. Investigation of the microstructure, mechanical properties and tribological behaviors of Ti-containing diamond-like carbon films fabricated by a hybrid ion beam method

    Energy Technology Data Exchange (ETDEWEB)

    Dai, Wei [Ningbo Key Laboratory of Marine Protection Materials, Division of Surface Engineering, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201 (China); Future Convergence Technology Division, Korea Institute of Science and Technology, Seoul, 130-650 (Korea, Republic of); Ke, Peiling [Ningbo Key Laboratory of Marine Protection Materials, Division of Surface Engineering, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201 (China); Moon, Myoung-Woon; Lee, Kwang-Ryeol [Future Convergence Technology Division, Korea Institute of Science and Technology, Seoul, 130-650 (Korea, Republic of); Wang, Aiying, E-mail: aywang@nimte.ac.cn [Ningbo Key Laboratory of Marine Protection Materials, Division of Surface Engineering, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201 (China)

    2012-07-31

    Diamond-like carbon (DLC) films with various titanium contents were investigated using a hybrid ion beam system comprising an anode-layer linear ion beam source and a DC magnetron sputtering unit. The film composition and microstructure were characterized carefully by X-ray photoelectron spectroscopy, transmission electron microscopy and Raman spectroscopy, revealing that the doped Ti atoms had high solubility in the DLC films. The maximum solubility was found to lie between about 7 and 13 at.%. When the Ti content was lower than this solubility, the doped Ti atoms dissolved in the DLC matrix and the films exhibited the typical features of the amorphous DLC structure and displayed low compressive stresses, friction coefficients and wear rates. However, as the doped content exceeded the solubility, Ti atoms bonded with C atoms, resulting in the formation of carbide nano-particles embedded in the DLC matrix. Although the emergence of the carbide nano-particles promoted graphitizing due to a catalysis effect, the film hardness was enhanced to a great extent. On the other hand, the hard carbides particles caused abrasive wear behavior, inducing a high friction coefficient and wear rate. - Highlights: Black-Right-Pointing-Pointer Ti doped DLC films (Ti {approx} 24 at.% )were deposited by a hybrid ion beam system. Black-Right-Pointing-Pointer Solubility of the Ti atoms in the DLC films was found around 7 {approx} 13 at .%. Black-Right-Pointing-Pointer Microstructure evolution from DLC to nanocomposite played key role in film behaviors.

  10. Effects of heat treatment on the corrosion resistance of carbon steel coated with LaMgAl11O19 thermal barrier coatings

    Institute of Scientific and Technical Information of China (English)

    Liang-liang Huang; Hui-min Meng; Li-kang Liang; Sen Li; Jin-hui Shi

    2015-01-01

    LaMgAl11O19 thermal barrier coatings (TBCs) were applied to carbon steels with a NiCoCrAlY bond coat by plasma spraying. The effects of heat treatment on the corrosion resistance of carbon steel coated with LaMgAl11O19 TBCs were investigated in 3.5wt% NaCl solution using polarization curves, electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM), and X-ray diffrac-tion (XRD). The results show that a large number of cracks are found in the LaMgAl11O19 TBCs after the samples are heat-treated, including some through-thickness cracks. The corrosion forms of the as-sprayed and heat-treated TBCs are uniform corrosion and pitting corrosion, respectively. The as-sprayed TBCs exhibit three EIS time constants after being immersed for less than 7 d, and then a new time constant ap-pears because of steel substrate corrosion. When the immersion time is increased to 56 d, a Warburg impedance (W) component appears in the EIS data. The EIS data for the heat-treated TBCs exhibit only two time constants after the samples are immersed for less than 14 d, and a new time constant appears when the immersion time is increased further. The heat treatment reduces the corrosion resistance of carbon steel coated with LaMgAl11O19 TBCs. The corrosion products are primarilyγ-FeOOH and Fe3O4.

  11. Three-dimensional thermal simulations of thin solid carbon foils for charge stripping of high current uranium ion beams at a proposed new heavy-ion linac at GSI

    Science.gov (United States)

    Tahir, N. A.; Kim, V.; Schlitt, B.; Barth, W.; Groening, L.; Lomonosov, I. V.; Piriz, A. R.; Stöhlker, Th.; Vormann, H.

    2014-04-01

    This paper presents an extensive numerical study of heating of thin solid carbon foils by 1.4 MeV/u uranium ion beams to explore the possibility of using such a target as a charge stripper at the proposed new Gesellschaft für Schwerionenforschung high energy heavy-ion linac. These simulations have been carried out using a sophisticated 3D computer code that accounts for physical phenomena that are important in this problem. A variety of beam and target parameters have been considered. The results suggest that within the considered parameter range, the target will be severely damaged by the beam. Thus, a carbon foil stripper does not seem to be a reliable option for the future Gesellschaft für Schwerionenforschung high energy heavy-ion linac, in particular, at FAIR design beam intensities.

  12. Electron-Beam Irradiation Effect on Thermal and Mechanical Properties of Nylon-6 Nanocomposite Fibers Infused with Diamond and Diamond Coated Carbon Nanotubes

    Science.gov (United States)

    Imam, Muhammad A.; Jeelani, Shaik; Rangari, Vijaya K.; Gome, Michelle G.; Moura, Esperidiana. A. B.

    2016-02-01

    Nylon-6 is an engineering plastic with excellent properties and processability, which are essential in several industrial applications. The addition of filler such as diamond (DN) and diamond coated carbon nanotubes (CNTs) to form molded composites may increase the range of Nylon-6 applications due to the resulting increase in strength. The effects of electron-beam irradiation on these thermoplastic nanocomposites are either increase in the cross-linking or causes chain scission. In this study, DN-coated CNTs were synthesized using the sonochemical technique in the presence of cationic surfactant cetyltrimethyl ammonium bromide (CTAB). The DN-coated CNTs nanoparticles and diamond nanoparticles were then introduced into Nylon-6 polymer through a melt extrusion process to form nanocomposite fibers. They were further tested for their mechanical (Tensile) and thermal properties (thermogravimetric analysis (TGA), differential scanning calorimetry (DSC)). These composites were further exposed to the electron-beam (160kGy, 132kGy and 99kGy) irradiation using a 1.5MeV electron-beam accelerator, at room temperature, in the presence of air and tested for their thermal and mechanical properties. The best ultimate tensile strength was found to be 690MPa and 864MPa irradiated at 132 for DN/CNTs/Nylon-6 and Diamond/Nylon-6 nanocomposite fiber as compared to 346MPa and 321MPa for DN/CNTs/Nylon-6 and Diamond/Nylon-6 nanocomposite fiber without irradiation. The neat Nylon-6 tensile strength was 240MPa. These results are consistent with the activation energy calculated from TGA graphs. DSC analysis result shows that the slight increase in glass transition temperature (Tg) and decrease in melting temperature (Tm) which was expected from high electron-beam radiation dose.

  13. MODIFICATION OF CARBON STEEL BY LASER SURFACE MELTING: PART II: EFFECT OF LASER BEAM POWER ON MICROSTRUCTURAL FEATURES AND SURFACE HARDNESS

    Directory of Open Access Journals (Sweden)

    Hashem F. El-Labban

    2013-01-01

    Full Text Available The surface hardness has an important effect on the wear resistance of different materials. The present study aims to improve the surface hardness of carbon steel through the application of laser surface melting with suitable conditions. The laser beam power and travelling speed are the main factors that affect the properties of the treated zone. In this study, three different conditions of laser beam power (1800, 1500 and 1200 W at fixed travelling speed of 1000 mm min-1 were chosen to study the effect of laser beam power. The resulted laser treated specimens were investigated in macro and microscopically scale using optical and scanning electron microscope. Hardness measurements were also carried out through the thickness of the laser treated zones. The laser treated areas with all used powers results in melted and solidified zone on the surface of the steel. The laser power of 1800 W results in the deepest value of the laser treated zone (about 1.7 mm. Moreover, by increasing the laser power, the width of the treated zone was slightly increases. At areas near the free surface, large martensite plates were observed in higher laser power (1800 W, while longer acicular martensite was observed in lower laser power (1200 W. For laser power of 1800 W, the bainite structures in ferrite grains were more pronounced in larger areas and in closer areas to the free surface. On the other hand, the lower laser power shows higher hardness on the free surface than that of higher power. The sizes of Heat Affect Zone (HAZ areas were increased by increasing the laser beam power. In all conditions, the heat affected zone areas were composed of partially decomposed pearlite in ferrite grains.

  14. Carbon-11 labeled stilbene derivatives from natural products for the imaging of Aβ plaques in the brain

    International Nuclear Information System (INIS)

    Four stilbene derivatives from natural products were screened as novel β-amyloid (Aβ) imaging ligands. In vitro binding assay showed that the methylated ligand, (E)-1-methoxy-4-styrylbenzene (8) displayed high binding affinity to Aβ1-42 aggregates (Ki = 19.5 nM). Moreover, the 11C-labeled ligand, [11C]8 was prepared through an O-methylation reaction using [11C]CH3OTf. In vitro autoradiography with sections of transgenic mouse brain also confirmed the high and specific binding of [11C]8 to Aβ plaques. In vivo biodistribution experiments in normal mice indicated that [11C]8 displayed high initial uptake (9.41 ± 0.51% ID/g at 5 min post-injection) into and rapid washout from the brain, with a brain5min/brain30min ratio of 6.63. These preliminary results suggest that [11C]8 may be served as a novel Aβ imaging probe for PET. (orig.)

  15. Report on compounds labelled with nitrogen-13 or carbon-11 used in cancer metabolic studies with quantitative two-dimensional scanning and pet tomography

    International Nuclear Information System (INIS)

    The use of compounds labelled with radionuclides of the elements commonly involved in metabolic processes (oxygen, carbon, nitrogen) is becoming important in the non-invasive study of organ and tumour function. The application of compounds labelled with 13N and 11C to the study of amino-acid metabolism and changes in vasculature following chemotherapy and radiation therapy is described. In particular, 13N-labelled L-glutamate has been found to be useful in visualizing a number of human tumours including osteogenic sarcoma, rhabdomyosarcoma, Ewing's sarcoma, malignant fibrous histiocytoma, pineal gland tumours, primitive neuroectodermal tumours, medulloblastoma and several other solid tumours. In patients with bone tumours, changes in 13N-L-glutamate scans during chemotherapy were found to correlate with changes in other clinical parameters, such as serum alkaline phosphatase, histology and 99Tcsup(m)-bone scans, thus indicating that labelled L-glutamate is potentially useful in evaluating the response of solid tumours to chemotherapy. Scans of patients and volunteers using 13N-L-glutamate and 13N-L-valine indicate that the L-amino acids may be useful in studies of metabolic processes in the liver, myocardium and pancreas. Red blood cells, labelled with 11C-carbon monoxide via inhalation of the radioactive gas, have been used to assess changes in tumour vascularity following radiation therapy. Alpha-aminoisobutyric acid labelled with 11C has been synthesized and its distribution in normal and tumour-bearing dogs has been studied. (author)

  16. Design and Analysis Methodologies for Inflated Beams

    NARCIS (Netherlands)

    Veldman, S.L.

    2005-01-01

    The central theme of the thesis is bending behaviour of inflated beams. Three different types of beams have been analysed for the bending load case: a straight cylindrical beam made of anisotropic foil material, a conical beam made of an isotropic foil material, and a carbon fibre braided beam. The

  17. Optical properties and structural investigations of (11-22)-oriented GaN/Al{sub 0.5}Ga{sub 0.5}N quantum wells grown by molecular beam epitaxy

    Energy Technology Data Exchange (ETDEWEB)

    Rosales, Daniel; Gil, Bernard; Bretagnon, Thierry [CNRS, Laboratoire Charles Coulomb, UMR 5221, F-34095 Montpellier (France); Université de Montpellier, Laboratoire Charles Coulomb, UMR 5221, F-34095 Montpellier (France); Brault, Julien; Vennéguès, Philippe; Nemoz, Maud; Mierry, Philippe de; Damilano, Benjamin; Massies, Jean [CNRS Centre de Recherche sur l' Hétéro-Epitaxie et ses Applications, 06560 Valbonne (France); Bigenwald, Pierre [Institut Pascal, Campus des Cézeaux, 24 avenue des Landais, 63171 Aubière Cedex (France)

    2015-07-14

    We have grown (11-22)-oriented GaN/Al{sub 0.5}Ga{sub 0.5}N quantum wells (QWs) using molecular beam epitaxy on GaN (11-22)-oriented templates grown by metal-organic vapor phase epitaxy on m-plane oriented sapphire substrates. The performance of epitaxial growth of GaN/Al{sub 0.5}Ga{sub 0.5}N heterostructures on the semi-polar orientation (11-22) in terms of surface roughness and structural properties, i.e., strain relaxation mechanisms is discussed. In addition, high resolution transmission electron microscopy reveals very smooth QW interfaces. The photoluminescence of such samples are strictly originating from radiative recombination of free excitons for temperatures above 100 K. At high temperature, the population of localized excitons, moderately trapped (5 meV) at low temperature, is negligible.

  18. Assessment of the effects of dobutamine on myocardial blood flow and oxidative metabolism in normal human subjects using nitrogen-13 ammonia and carbon-11 acetate.

    Science.gov (United States)

    Krivokapich, J; Huang, S C; Schelbert, H R

    1993-06-01

    The dual purposes of this study with positron emission tomography were to measure the effects of dobutamine on myocardial blood flow and oxidative metabolism, and to compare carbon-11 (C-11) acetate versus nitrogen-13 (N-13) ammonia in quantitating flow in normal subjects. Flow was quantitated with N-13 ammonia at rest and at peak dobutamine infusion (40 micrograms/kg/min) in 21 subjects. In 11 subjects, oxidative metabolism was also estimated at rest and peak dobutamine infusion using the clearance rate of C-11 acetate, k mono (min-1). A 2-compartment kinetic model was applied to the early phase of the C-11 acetate data to estimate flow. The rest and peak dobutamine rate-pressure products were 7,318 +/- 1,102 and 19,937 +/- 3,964 beats/min/mm Hg, respectively, and correlated well (r = 0.77) with rest and peak dobutamine flows of 0.77 +/- 0.14 and 2.25 ml/min/g determined using N-13 ammonia as a flow tracer. Rest and dobutamine flows estimated with C-11 acetate were highly correlated with those determined with N-13 ammonia (r = 0.92). k mono increased from 0.05 +/- 0.01 to 0.18 +/- 0.02 min-1, and correlated highly with the increase in flows (r = 0.91) and rate-pressure products (r = 0.94). Thus, the increase in cardiac demand associated with dobutamine is highly correlated with an increase in supply and oxidative metabolism. C-11 acetate is a unique tracer that can be used to image both flow and metabolism simultaneously. PMID:8498380

  19. Synergistic effect of heat shock protein 90 inhibitor, 17-allylamino-17-demethoxygeldanamycin and X-rays, but not carbon-ion beams, on lethality in human oral squamous cell carcinoma cells

    International Nuclear Information System (INIS)

    The purpose of this study is to clarify the effect of a heat shock protein 90 inhibitor, 17-allylamino-17-demethoxygeldanamycin (17-AAG), in combination with X-rays or carbon-ion beams on cell killing in human oral squamous cell carcinoma LMF4 cells. Cell survival was measured by colony formation assay. Cell-cycle distribution was analyzed by flow cytometry. Expression of DNA repair-related proteins was investigated by western blotting. The results showed 17-AAG to have synergistic effects on cell lethality with X-rays, but not with carbon-ion beams. The 17-AAG decreased G2/M arrest induced by X-rays, but not by carbon-ion beams. Both X-ray and carbon-ion irradiation up-regulated expression of non-homologous end-joining-associated proteins, Ku70 and Ku80, but 17-AAG inhibited only X-ray-induced up-regulation of these proteins. These results show that 17-AAG with X-rays releases G2/M phase arrest; cells carrying misrepaired DNA damage then move on to the G1 phase. We demonstrate, for the first time, that the radiosensitization effect of 17-AAG is not seen with carbon-ion beams because 17-AAG does not affect these changes. (author)

  20. 进氧化氢在微过氧化物酶-11(MP-11)修饰玻碳电极上的电催化还原%Electrocatalytic Reduction of Hydrogen Peroxide on the Microperoxidase-11 Modified Glass Carbon Electrode

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    @@ 0 Introduction MP-11 is obtained from pepsin digestion of cytochrome c.It retains amino acid residues 11-21 of cytochrome c.It is considered a good model of c-type heme enzymes and peroxidases.So far,some methods have been used to immobilize MP-11 on electrodes,such as mixing up with graphite paste[1],covalently combining to the thiol or cystamine monolayer self-assembled at the gold electrode[2,3].This paper reports that MP-11 convalently bound on a glass carbon electrode through glutaraldehyde coupling of the peptide to a hydrazino-alkoxysilane exhibits high electrocatalytic activity for the reduction of H2O2.

  1. Specific activity of [{sup 11}C]CH{sub 3}I synthesized by the 'wet' method: Main sources of non-radioactive carbon

    Energy Technology Data Exchange (ETDEWEB)

    Gomez-Vallejo, Vanessa [Institut Alta Tecnologia PRBB-Fundacio Privada, Parc de Recerca Biomedica de Barcelona, C/Dr. Aiguader, 88 08003 Barcelona (Spain); Llop, Jordi [Institut Alta Tecnologia PRBB-Fundacio Privada, Parc de Recerca Biomedica de Barcelona, C/Dr. Aiguader, 88 08003 Barcelona (Spain)], E-mail: jllop@cicbiomagune.es

    2009-01-15

    Positron emission tomography (PET) is a powerful molecular imaging technique based on the administration and detection of radioactive (positron emitting) species. In some applications, the concept of specific activity becomes especially important in order to prevent undesired pharmacological and/or toxic effects after injection of the radiotracer. Problems to obtain high specific activities are found when {sup 11}C-labeled compounds are prepared by methylation following the so called 'wet' method, which consists of a simple route but usually yields radiotracers highly diluted with the stable specie. In the present work, the main sources of contamination by stable carbon in the [{sup 11}C]CH{sub 3}I synthesis following the 'wet' method have been analyzed and their individual contribution has been quantified. The results show that the most relevant contamination of CO{sub 2} is generated during the bombardment process.

  2. Synthesis of carbon-11 labelled SCH 39166, a new selective dopamine D-1 receptor ligand, and preliminary PET investigations

    Energy Technology Data Exchange (ETDEWEB)

    Halldin, Christer; Farde, Lars; Sedvall, Goeran (Karolinska Hospital, Stockholm (Sweden). Dept. of Psychiatry and Psychology); Barnett, Allen (Schering-Plough Corp., Bloomfield, NJ (USA))

    1991-01-01

    SCH 39166 ((-)-trans-6,7,7a,8,9,13b-hexahydro-3-chloro-2-hydroxy-N-methyl-5H-benzo(d)naphtho-(2,1-b)azepine ) is a new more selective dopamine D-1 receptor antagonist than the widely used SCH 23390. ({sup 11}C)SCH 39166 was prepared by N-methylation of the desmethyl compound SCH 40853 ((-)-trans-6,7,7a,8,9,13b-hexahydro-3-chloro-2-hydroxy-5H-benzo(d)naphtho -(2,1-b)azepine) with ({sup 11}C)methyl iodide. Reaction in acetone with subsequent straight-phase semi-preparative HPLC resulted in 20-30% radiochemical yield (from EOB and decay-corrected) with a total synthesis time of 35-40 min and a radiochemical purity >99%. The specific activity obtained at EOS was about 1500 Ci/mmol (55 GBq/{mu}mol). ({sup 11}C)SCH 39166 was injected into a Cynomolgus monkey. PET-analysis demonstrated accumulation in the striatum, a region known to have a high density of dopamine D-1 receptors. In a displacement experiment, radioactivity in the striatum was markedly reduced after injection of 6 mg unlabelled SCH 23390, thus demonstrating the specificity and reversibility of ({sup 11}C)SCH 39166 binding to dopamine D-1 receptors. (author).

  3. Thick-target neutron, gamma-ray, and radionuclide production for protons below 12 MeV on nickel and carbon beam-stops

    Energy Technology Data Exchange (ETDEWEB)

    Chadwick, M.B.; Young, P.G.; Wilson, W.B.

    1998-03-01

    Nuclear model calculations using the GNASH code are described for protons below 12 MeV incident on nickel and carbon isotopes, for beam stop design in the Los Alamos Accelerator Production of Tritium Low Energy Demonstration Accelerator (LEDA) project. The GNASH calculations apply Hauser-Feshbach and preequilibrium reaction theories and can make use of pre-calculated direct reaction cross sections to low-lying residual nucleus states. From calculated thin target cross sections, thick target 6.7 MeV and 12 MeV proton-induced production of neutrons, gamma rays, and radionuclides are determined. Emission spectra of the secondary neutrons and gamma rays are also determined. The model calculations are validated through comparisons with experimental thin- and thick-target measurements. The results of this work are being utilized as source terms in MCNP analyses for LEDA.

  4. A study of V79 cell survival after for proton and carbon ion beams as represented by the parameters of Katz' track structure model

    DEFF Research Database (Denmark)

    Grzanka, Leszek; Waligórski, M. P. R.; Bassler, Niels

    Katz’s theory of cellular track structure (1) is an amorphous analytical model which applies a set of four cellular parameters representing survival of a given cell line after ion irradiation. Usually the values of these parameters are best fitted to a full set of experimentally measured survival...... curves available for a variety of ions. Once fitted, using these parameter values and the analytical formulae of the model calculations, cellular survival curves and RBE may be predicted for that cell line after irradiation by any ion, including mixed ion fields. While it is known that the Katz model...... carbon irradiation. 1. Katz, R., Track structure in radiobiology and in radiation detection. Nuclear Track Detection 2: 1-28 (1978). 2. Furusawa Y. et al. Inactivation of aerobic and hypoxic cells from three different cell lines by accelerated 3He-, 12C- and 20Ne beams. Radiat Res. 2012 Jan; 177...

  5. Monte Carlo simulations of the relative biological effectiveness for DNA double strand breaks from 300 MeV u−1 carbon-ion beams

    International Nuclear Information System (INIS)

    Monte Carlo simulations are used to calculate the relative biological effectiveness (RBE) of 300 MeV u−1 carbon-ion beams at different depths in a cylindrical water phantom of 10 cm radius and 30 cm long. RBE values for the induction of DNA double strand breaks (DSB), a biological endpoint closely related to cell inactivation, are estimated for monoenergetic and energy-modulated carbon ion beams. Individual contributions to the RBE from primary ions and secondary nuclear fragments are simulated separately. These simulations are based on a multi-scale modelling approach by first applying the FLUKA (version 2011.2.17) transport code to estimate the absorbed doses and fluence energy spectra, then using the MCDS (version 3.10A) damage code for DSB yields. The approach is efficient since it separates the non-stochastic dosimetry problem from the stochastic DNA damage problem. The MCDS code predicts the major trends of the DSB yields from detailed track structure simulations. It is found that, as depth is increasing, RBE values increase slowly from the entrance depth to the plateau region and change substantially in the Bragg peak region. RBE values reach their maxima at the distal edge of the Bragg peak. Beyond this edge, contributions to RBE are entirely from nuclear fragments. Maximum RBE values at the distal edges of the Bragg peak and the spread-out Bragg peak are, respectively, 3.0 and 2.8. The present approach has the flexibility to weight RBE contributions from different DSB classes, i.e. DSB0, DSB+ and DSB++. (paper)

  6. Under-response of a PTW-60019 microDiamond detector in the Bragg peak of a 62 MeV/n carbon ion beam

    Science.gov (United States)

    Rossomme, S.; Hopfgartner, J.; Vynckier, S.; Palmans, H.

    2016-06-01

    To investigate the linear energy transfer (LET) dependence of the response of a PTW-60019 Freiburg microDiamond detector, its response was compared to the response of a plane-parallel Markus chamber in a 62 MeV/n mono-energetic carbon ion beam. Results obtained with two different experimental setups are in agreement. As recommended by IAEA TRS-398, the response of the Markus chamber was corrected for temperature, pressure, polarity effects and ion recombination. No correction was applied to the response of the microDiamond detector. The ratio of the response of the Markus chamber to the response of the microDiamond is close to unity in the plateau region. In the Bragg peak region, a significant increase of the ratio is observed, which increases to 1.2 in the distal edge region. Results indicate a correlation between the under-response of the microDiamond detector and high LET values. The combined relative standard uncertainty of the results is estimated to be 2.38% in the plateau region and 12% in the distal edge region. These values are dominated by the uncertainty of alignment in the non-uniform beam and the uncertainty of range determination.

  7. Under-response of a PTW-60019 microDiamond detector in the Bragg peak of a 62 MeV/n carbon ion beam.

    Science.gov (United States)

    Rossomme, S; Hopfgartner, J; Vynckier, S; Palmans, H

    2016-06-21

    To investigate the linear energy transfer (LET) dependence of the response of a PTW-60019 Freiburg microDiamond detector, its response was compared to the response of a plane-parallel Markus chamber in a 62 MeV/n mono-energetic carbon ion beam. Results obtained with two different experimental setups are in agreement. As recommended by IAEA TRS-398, the response of the Markus chamber was corrected for temperature, pressure, polarity effects and ion recombination. No correction was applied to the response of the microDiamond detector. The ratio of the response of the Markus chamber to the response of the microDiamond is close to unity in the plateau region. In the Bragg peak region, a significant increase of the ratio is observed, which increases to 1.2 in the distal edge region. Results indicate a correlation between the under-response of the microDiamond detector and high LET values. The combined relative standard uncertainty of the results is estimated to be 2.38% in the plateau region and 12% in the distal edge region. These values are dominated by the uncertainty of alignment in the non-uniform beam and the uncertainty of range determination. PMID:27224547

  8. Measurement of neutron spectra generated by a 62 AMeV carbon-ion beam on a PMMA phantom using extended range Bonner sphere spectrometers

    Science.gov (United States)

    Bedogni, R.; Amgarou, K.; Domingo, C.; Russo, S.; Cirrone, G. A. P.; Pelliccioni, M.; Esposito, A.; Pola, A.; Introini, M. V.; Gentile, A.

    2012-07-01

    Neutrons constitute an important component of the radiation environment in hadron therapy accelerators. Their energy distribution may span from thermal up to hundred of MeV. The characterization of these fields in terms of dosimetric or spectrometric quantities is crucial for either the patient protection or the facility design aspects. To date, the Extended Range Bonner Sphere Spectrometer (ERBSS) is the only instrument able to simultaneously determine all spectral components in such workplaces. With the aim of providing useful data to the scientific community involved in neutron measurements at hadron therapy facilities, a measurement campaign was carried out at the Centro di AdroTerapia e Applicazioni Nucleari Avanzate (CATANA) of INFN-LNS (Laboratori Nazionali del Sud), where a 62 AMeV carbon ion is available. The beam was directed towards a PMMA phantom, simulating the patient, and two neutron measurement points were established at 0° and 90° with respect to the beam-line. The ERBSSs of UAB (Universidad Autónoma de Barcelona-Grup de Física de les Radiacions) and INFN (Istituto Nazionale di Fisica Nucleare-Laboratori Nazionali di Frascati) were used to measure the resulting neutron fields. The two ERBSSs use different detectors and sphere diameters, and have been independently calibrated. The FRUIT code was used to unfold the results.

  9. Measurement of neutral current neutral pion production on Carbon in a Few-GeV Neutrino Beam

    OpenAIRE

    Kurimoto, Y

    2009-01-01

    The SciBooNE Collaboration has measured neutral current neutral pion production by the muon neutrino beam at a polystyrene target (C8H8). We obtained (7.7+- 0.5(stat.)+0.4-0.5 (sys.)) x 10^-2 as cross section ratio of the neutral current neutral pion production to total charged current cross section at the mean neutrino energy of 1.16 GeV. This result is consistent with the Monte Carlo prediction based on the Rein-Sehgal model

  10. Speed and accuracy of a beam tracking system for treatment of moving targets with scanned ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Nami; Bert, Christoph; Chaudhri, Naved; Gemmel, Alexander; Schardt, Dieter; Durante, Marco; Rietzel, Eike [GSI Helmholtz Centre for Heavy Ion Research GmbH, Planckstrasse 1, 64291 Darmstadt (Germany)], E-mail: n.saito@gsi.de

    2009-08-21

    The technical performance of an integrated three-dimensional carbon ion pencil beam tracking system that was developed at GSI was investigated in phantom studies. Aim of the beam tracking system is to accurately treat tumours that are subject to respiratory motion with scanned ion beams. The current system provides real-time control of ion pencil beams to track a moving target laterally using the scanning magnets and longitudinally with a dedicated range shifter. The system response time was deduced to be approximately 1 ms for lateral beam tracking. The range shifter response time has been measured for various range shift amounts. A value of 16 {+-} 2 ms was achieved for a water equivalent shift of 5 mm. An additional communication delay of 11 {+-} 2 ms was taken into account in the beam tracking process via motion prediction. Accuracy of the lateral beam tracking was measured with a multi-wire position detector to {<=}0.16 mm standard deviation. Longitudinal beam tracking accuracy was parameterized based on measured responses of the range shifter and required time durations to maintain a specific particle range. For example, 5 mm water equivalence (WE) longitudinal beam tracking results in accuracy of 1.08 and 0.48 mm WE in root mean square for time windows of 10 and 50 ms, respectively.

  11. MODIFICATION OF CARBON STEEL BY LASER SURFACE MELTING: PART I: EFFECT OF LASER BEAM TRAVELLING SPEED ON MICROSTRUCTURAL FEATURES AND SURFACE HARDNESS

    Directory of Open Access Journals (Sweden)

    Hashem F. El-Labban

    2013-01-01

    Full Text Available The present study aims to improve the surface hardness of carbon steel by application of laser surface melting of effective conditions. The travelling speed of laser beam during this treatment is one of the important treatment conditions. This study aims to investigate the effect of laser surface melting with different beam speeds on macro and microstructure as well as the hardness distribution through the thickness of carbon steel. To achieve this target, three different travelling speeds (1500, 1000 and 500 mm min-1 at a constant beam power of 800 W were chosen in this study. The resulted laser treated specimens were investigated in macro and microscopically scale using optical and scanning electron microscope. Hardness measurements were also carried out through the thickness of the laser treated specimens. The laser treated areas with all used travelling speeds results in melted and solidified zone on the surface of the steel. In the same time, Plates of acicular martensite structure were observed within the upper part of the melted and solidified zone in almost all experimental conditions, while some bainite structure in ferrite grains are detected in its lower part. By increasing the travelling speed, the depth of the laser treated zone was decreases, while travelling speed has much less significant effect on the laser treated zone width. The size of the formed martensite plates was increased by decreasing the travelling speed from 1500 to 500 mm min-1. On the other hand, the travelling speed has a straight effect on the length of the acicular martensite; as the travelling speed increases, the acicular martensite became longer, while it shows fine acicular martensite at lower travelling speeds. The depth that full martensite structure can be reached is increased by increasing travelling speed. At lower travelling speed (500 mm min-1, large amount of bainite structure is observed at the center of the treated zone up to its lower end. The

  12. Risk of simulated microgravity on testicular injury induced by high-LET carbon-ion beams in mice

    International Nuclear Information System (INIS)

    This study investigated the impact of simulated microgravity on acute injury induced by low doses of carbon ions in male reproductive organs of mice, and determined alterations in spermatogenic function and expression levels of apoptotic factors in mice following exposure to acute irradiation after 7 days of simulated microgravity. The results demonstrated that significant reductions in spermatozoa, primary spermatocytes and spermatogonia, and increased globular cells in seminiferous tubule and pro-apoptotic proteins were observed in the group exposed to over 0.4 Gy irradiation. Collectively, the data suggest that lesions inflicted by simulated microgravity are not markedly modified by lower doses of irradiation (0.2 Gy) in mouse testis compared to the control group. However, testicular impairments were markedly evident in the group exposed to higher doses of carbon ions plus simulated microgravity, which may be due at least in part to elevated apoptosis initiated by the mitochondrial apoptosis pathway in germ cells. (authors)

  13. Graphene crystal growth by thermal precipitation of focused ion beam induced deposition of carbon precursor via patterned-iron thin layers

    Directory of Open Access Journals (Sweden)

    Rius Gemma

    2014-01-01

    Full Text Available Recently, relevant advances on graphene as a building block of integrated circuits (ICs have been demonstrated. Graphene growth and device fabrication related processing has been steadily and intensively powered due to commercial interest; however, there are many challenges associated with the incorporation of graphene into commercial applications which includes challenges associated with the synthesis of this material. Specifically, the controlled deposition of single layer large single crystal graphene on arbitrary supports, is particularly challenging. Previously, we have reported the first demonstration of the transformation of focused ion beam induced deposition of carbon (FIBID-C into patterned graphitic layers by metal-assisted thermal treatment (Ni foils. In this present work, we continue exploiting the FIBID-C approach as a route for graphene deposition. Here, thin patterned Fe layers are used for the catalysis of graphenization and graphitization. We demonstrate the formation of high quality single and few layer graphene, which evidences, the possibility of using Fe as a catalyst for graphene deposition. The mechanism is understood as the minute precipitation of atomic carbon after supersaturation of some iron carbides formed under a high temperature treatment. As a consequence of the complete wetting of FIBID-C and patterned Fe layers, which enable graphene growth, the as-deposited patterns do not preserve their original shape after the thermal treatment

  14. Estudio Experimental de Piezas Lineales de Hormigón Reforzadas con Fibras de Carbono Experimental Study of Reinforced Concrete Beams Strengthened with Carbon Fibers

    Directory of Open Access Journals (Sweden)

    M. Valcuende

    2004-01-01

    Full Text Available Se ha estudiado el comportamiento de seis vigas reforzadas simultáneamente con láminas y tejidos de fibra de carbono. Se analiza, para este tipo de refuerzos, la validez de dos de los métodos de cálculo posiblemente más utilizados. En ambos métodos se plantean las ecuaciones de equilibrio de fuerzas y momentos, pero se introducen suposiciones diferentes: i el acero tiene suficiente capacidad plástica para no romperse y ii el agotamiento se produce siempre por rotura de la lámina. Los resultados obtenidos ponen de manifiesto que refuerzos de láminas y tejidos de fibra de carbono influyen notablemente sobre las piezas, mejorando su capacidad portante y modificando su comportamiento estructural en cuanto a rigidez y ductilidadA study on the behaviour of six beams reinforced with carbon fiber laminates and fabrics was done. The validity of the two most commonly used methods of evaluating the effects of these reinforcements was analyzed. Both methods propose equilibrium equations based on forces and moments, although introducing two different suppositions: i that the steel posesses enough elasticity to avoid breakage, and ii failure is always produced by the breakage of the laminate. The results obtained demonstrate that carbon fiber laminates and fabric reinforcements have notable influence on the pieces, improving their loading capacities and modifying their structural behavior regarding stiffness and ductility

  15. Taking out one billion tones of carbon: the magic of China's 11th Five-Year Plan

    OpenAIRE

    Lin, Jiang; Zhou, Nan; Levine, Mark D.; Fridley, David

    2007-01-01

    China's 11th Five-Year Plan (FYP) sets an ambitious target for energy-efficiency improvement: energy intensity of the country s gross domestic product (GDP) should be reduced by 20 percent from 2005 to 2010 (NDRC, 2006). This is the first time that a quantitative and binding target has been set for energy efficiency, and signals a major shift in China's strategic thinking about its long-term economic and energy development. The 20 percent energy intensity target also translates into an a...

  16. Monte Carlo Calculations of Dose to Medium and Dose to Water for Carbon Ion Beams in Various Media

    DEFF Research Database (Denmark)

    Herrmann, Rochus; Petersen, Jørgen B.B.; Jäkel, Oliver;

    treatment plans. Here, we quantisize the effect of dose to water vs. dose to medium for a series of typical target materials found in medical physics. 2     Material and Methods The Monte Carlo code FLUKA [Battistioni et al. 2007] is used to simulate the particle fluence spectrum in a series of target......1     Background In clinical practice the quantity dose to water (Dw ) is used as a reference standard for dosimeters and treatment planning systems. Treatment planning systems usually rely on analytical representation of the particle beam, which are normally expressed as dose with respect to water...... for water. This represents the case that our “detector” is an infinitesimal small non-perturbing entity made of water, where charged particle equilibrium can be assumed following the Bragg-Gray cavity theory. Dw and Dm are calculated for typical materials such as bone, brain, lung and soft-tissues using...

  17. Comparison between computed and measured response of silicon strip detectors exposed to carbon, calcium and ruthenium ion beams

    International Nuclear Information System (INIS)

    The response of silicon strip detectors exposed to energetic heavy ions in the energy interval from 0.3 up to 1.4 GeV/u has been measured at the SIS accelerator at GSI. The energy deposit spectra are characterized by their mean values and widths. The carbon data, at various energies, agree within the accuracy of the measurements with the computed response of the detector. The measured widths of the energy deposit spectra for ruthenium are narrower than those calculated by the appropriate Vavilov distributions. Energetic δ-rays overflowing from the silicon detector is considered as a possible explanation for the disagreement between computed and measured widths

  18. Comparison between computed and measured response of silicon strip detectors exposed to carbon, calcium and ruthenium ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Codino, A. E-mail: antonio.codino@codino-pc.pg.infn.it; Plouin, F.; Bellachioma, C.; Brunetti, M.T.; Checcucci, B.; Federico, C.; Lanfranchi, M.; Maffei, P.; Miozza, M.; Vocca, H

    2003-09-01

    The response of silicon strip detectors exposed to energetic heavy ions in the energy interval from 0.3 up to 1.4 GeV/u has been measured at the SIS accelerator at GSI. The energy deposit spectra are characterized by their mean values and widths. The carbon data, at various energies, agree within the accuracy of the measurements with the computed response of the detector. The measured widths of the energy deposit spectra for ruthenium are narrower than those calculated by the appropriate Vavilov distributions. Energetic {delta}-rays overflowing from the silicon detector is considered as a possible explanation for the disagreement between computed and measured widths.

  19. Production of an accelerated oxygen-14 beam

    CERN Document Server

    Powell, J; Cerny, J

    2003-01-01

    BEARS is an ongoing project to provide a light-ion radioactive-beam capability at the 88-Inch Cyclotron at LBNL. Light radioactive isotopes are produced at a 10 MeV proton medical cyclotron, transported 350 m via a high-speed gas transport capillary, cryogenically separated, and injected into the 88-Inch Cyclotron's ion source. The first radioactive beam successfully accelerated was carbon-11 and beams of intensity more than 10 sup 8 ions/s have been utilized for experiments. Development of oxygen-14 as the second BEARS beam presented considerable technical challenges, both due to its short half-life of 71 s and the radiation chemistry of oxygen in the target. The usual techniques developed for medical uses of oxygen-15 involve the addition of significant amounts of carrier oxygen, something that would overload the ion source. As a solution, oxygen-14 is produced as water in a carrier-free form, and is chemically converted in two steps to carbon dioxide, a form readily usable by the BEARS. This system has bee...

  20. Simulations of Full Impact of the LHC Beam With a Solid Graphite Target

    CERN Document Server

    Tahir, N A; Brugger, M; Shutov, A; Lomonosov, I V; Piriz, A R; Hoffmann, D H H

    2009-01-01

    The Large Hadron Collider (LHC) will operate with 7~TeV/c protons with a luminosity of 10$^{34}$ cm$^{-2}$s$^{-1}$. This requires two beams, each with 2808 bunches. The nominal intensity per bunch is 1.15$\\;\\times\\;$10$^{11}$ protons and the total energy stored in each beam is 362 MJ. In previous papers, the mechanisms causing equipment damage in case of a failure of the machine protection system was discussed, assuming that the entire beam is deflected onto a copper target. Another failure scenario is the deflection of beam, or part of it, into carbon material. Carbon collimators and beam absorbers are installed in many locations around the LHC close to the beam, since carbon is the material that is most suitable to absorb the beam energy without being damaged. In case of a failure, it is very likely that such absorbers are hit first, for example, when the beam is accidentally deflected. Some type of failures need to be anticipated, such as accidental firing of injection and extraction kicker magnets leading...

  1. Production of radioactive molecular beams for CERN-ISOLDE

    CERN Document Server

    AUTHOR|(SzGeCERN)703149; Kröll, Thorsten

    SOLDE, the Isotope Separation On-Line facility, at CERN is a leading facility for the production of beams of exotic radioactive isotopes. Currently over 1000 different isotopes with half lives down to milliseconds can be extracted with beam intensities of up to 10^11 ions per second. However, due to the reactive target environment not all isotopes are extractable in sufficient amounts. In this work the extraction of short lived carbon and boron isotopes is investigated. Therefore a variety of experimental and computanional techniques have been used.

  2. Production of radioactive molecular beams for CERN-ISOLDE

    Energy Technology Data Exchange (ETDEWEB)

    Seiffert, Christoph

    2015-06-15

    ISOLDE, the Isotope Separation On-Line facility, at CERN is a leading facility for the production of beams of exotic radioactive isotopes. Currently over 1000 different isotopes with half lives down to milliseconds can be extracted with beam intensities of up to 10{sup 11} ions per second. However, due to the reactive target environment not all isotopes are extractable in sufficient amounts. In this work the extraction of short lived carbon and boron isotopes is investigated. Therefore a variety of experimental and computational techniques have been used.

  3. Fragmentation of 200 and 244 MeV/u carbon beams in thick tissue-like absorbers

    International Nuclear Information System (INIS)

    Stacks consisting of thin CR-39 sheets sandwiched between thick lucite and water absorbers were perpendicularly bombarded by 12C ions at 200 and 244 MeV/u. Track radius distributions representing the charge composition of the fragmented beams were automatically measured by a particle track analysis system. After analysis of the nuclear charge distributions, the total charge removal cross-sections and elemental production cross-sections of fragments with atomic numbers from 5 to 3, were obtained down to the lower energies (∼50 and 100 MeV/u, respectively). It has been found that the measured total charge removal cross-section agrees with theoretical predictions within ∼10% and very well with previous experiments in corresponding energy regions. Two model calculations for production of B fragment are in good agreement with our measured data while a third model overestimates it by ∼12%. Theoretical cross-sections for Be and Li fragments differ strongly among the different models and from measured values

  4. The relative biological effectiveness for carbon and oxygen ion beams using the raster-scanning technique in hepatocellular carcinoma cell lines.

    Directory of Open Access Journals (Sweden)

    Daniel Habermehl

    Full Text Available BACKGROUND: Aim of this study was to evaluate the relative biological effectiveness (RBE of carbon (12C and oxygen ion (16O-irradiation applied in the raster-scanning technique at the Heidelberg Ion beam Therapy center (HIT based on clonogenic survival in hepatocellular carcinoma cell lines compared to photon irradiation. METHODS: Four human HCC lines Hep3B, PLC, HepG2 and HUH7 were irradiated with photons, 12C and 16O using a customized experimental setting at HIT for in-vitro trials. Cells were irradiated with increasing physical photon single doses of 0, 2, 4 and 6 Gy and heavy ion-single doses of 0, 0.125, 0.5, 1, 2, 3 Gy (12C and 16O. SOBP-penetration depth and extension was 35 mm +/-4 mm and 36 mm +/-5 mm for carbon ions and oxygen ions respectively. Mean energy level and mean linear energy transfer (LET were 130 MeV/u and 112 keV/um for 12C, and 154 MeV/u and 146 keV/um for 16O. Clonogenic survival was computated and relative biological effectiveness (RBE values were defined. RESULTS: For all cell lines and both particle modalities α- and β-values were determined. As expected, α-values were significantly higher for 12C and 16O than for photons, reflecting a steeper decline of the initial slope of the survival curves for high-LET beams. RBE-values were in the range of 2.1-3.3 and 1.9-3.1 for 12C and 16O, respectively. CONCLUSION: Both irradiation with 12C and 16O using the raster-scanning technique leads to an enhanced RBE in HCC cell lines. No relevant differences between achieved RBE-values for 12C and 16O were found. Results of this work will further influence biological-adapted treatment planning for HCC patients that will undergo particle therapy with 12C or 16O.

  5. Density dependence of the polarization of the 23P1 → 11S0 intercombination line emitted by helium-like neon excited by an electron beam

    International Nuclear Information System (INIS)

    The linear polarization of the x-ray 1s2p3P1 → 1s21S0 intercombination line emitted by helium-like Ne8+ ion collisionally excited by a monoenergetic electron beam has been theoretically studied versus electron densities, from 109 to 5 x 1013 cm-3. In addition to direct excitation from the 1s2 ground level and radiative cascades from 1s3l higher levels, excitation from the 1s2s3S1 metastable level was included in the collisional-radiative model. Collision strengths for transitions between magnetic sublevels were computed at three incident electron energies above the 1s2 → 1s2l excitation threshold (68, 90 and 140 Ry, i.e. 925, 1225 and 1905 eV), using a semi-relativistic distorted-wave approximation for partial waves up to l = 40 and a Coulomb-Bethe top-up for higher l. For electron densities below 1010 cm-3, the intercombination line is found to be polarized between -49.1% and -41.0% in the range of impact energies chosen. With increasing density, the polarization degree rapidly decreases in absolute value to zero, then becomes positive. Similar results for the polarization of the 1s2s3S1 → 1s21S0 forbidden and 1s2p3P2 → 1s2s3S1 dipole-allowed lines are also given

  6. An overview of nuclear micro-beam analysis of surface and bulk fuel retention in carbon-fibre composites from Tore Supra

    International Nuclear Information System (INIS)

    Surface and bulk retention of deuterium in tiles of the pump limiter from Tore Supra was examined with nuclear reaction analysis using both standard and micro-beam techniques. The aim was to determine the variations in the content and distribution of fuel species in carbon-fibre composites. On plasma-facing surfaces from the deposition zone, the D content reaches 2.5 x 1019 cm-2 in about 8 μm thick top layer, but lateral differences reach even more than one order of magnitude. This is also measured in the erosion zone: 6.6 x 1017 cm-2 to 7.7 x 1018 cm-2 D atoms. Bulk content was examined on cross-sections opened by fracturing the tiles. Fuel is detected up to the depth of 1-1.5 mm beneath the plasma-facing surface in tiles from both the erosion and deposition zones. It occurs in bands, about 100 μm wide and several mm long, roughly parallel to the original plasma-facing surface.

  7. Rabi Wave Packets and Peculiarities of Raman Scattering in Carbon Nanotubes, Produced by High Energy Ion Beam Modification of Diamond Single Crystals

    CERN Document Server

    Yearchuck, Dmitry

    2011-01-01

    QED-model for multichain coupled qubit system, proposed in \\cite{Part1}, was confirmed by Raman scattering studies of quasi-1D carbon zigzag-shaped nanotubes (CZSNTs), produced by high energy ion beam modification of natural diamond single crystals. Multichain coupled qubit system represents itself Su-Schriffer-Heeger $\\sigma$-polaron lattice, formed in CZSNTs plus quantized external electromagnetic (EM) field. New quantum optics phenomenon - Rabi waves, predicted in \\cite{Slepyan_Yerchak} has experimentally been identified for the first time. It is shown, that Raman spectra in quasi-1D CZSNTs are quite different in comparison with well known Raman spectra in 2D those ones. They characterized by semiclassical consideration by the only one vibronic mode of Su-Schriffer-Heeger $\\sigma$-polaron lattice instead of longitudinal and transverse optical phonon $G^+$ and $G^-$modes and the out-of-plane radial breathing mode, which are observed in Raman spectra of 2D single wall nanotubes. It is consequence of 2D - 1D ...

  8. Simple model of bulk and surface excitation effects to inelastic scattering in low-energy electron beam irradiation of multi-walled carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Kyriakou, Ioanna; Emfietzoglou, Dimitris [Medical Physics Lab, University of Ioannina Medical School, 451 10 Ioannina (Greece); Garcia-Molina, Rafael [Departamento de Fisica - CIOyN, Universidad de Murcia, E-30100 Murcia (Spain); Abril, Isabel [Departament de Fisica Aplicada, Universitat d' Alacant, Apartat 99, E-03080 Alacant (Spain); Kostarelos, Kostas [Nanomedicine Lab, Centre for Drug Delivery Research, The School of Pharmacy, University of London, London WC1N 1AX (United Kingdom)

    2011-09-01

    The effect of bulk and surface excitations to inelastic scattering in low-energy electron beam irradiation of multi-walled carbon nanotubes (MWNTs) is studied using the dielectric formalism. Calculations are based on a semiempirical dielectric response function for MWCNTs determined by means of a many-pole plasmon model with parameters adjusted to available experimental spectroscopic data under theoretical sum-rule constrains. Finite-size effects are considered in the context of electron gas theory via a boundary correction term in the plasmon dispersion relations, thus, allowing a more realistic extrapolation of the electronic excitation spectrum over the whole energy-momentum plane. Energy-loss differential and total inelastic scattering cross sections as a function of electron energy and distance from the surface, valid over the energy range {approx}50-30,000 eV, are calculated with the individual contribution of bulk and surface excitations separated and analyzed for the case of normally incident and escaping electrons. The sensitivity of the results to the various approximations for the spatial dispersion of the electronic excitations is quantified. Surface excitations are shown to have a strong influence upon the shape and intensity of the energy-loss differential cross section in the near surface region whereas the general notion of a spatially invariant inelastic mean free path inside the material is found to be of good approximation.

  9. Near edge X-ray absorption fine structure study for optimization of hard diamond-like carbon film formation with Ar cluster ion beam

    CERN Document Server

    Kitagawa, T; Kanda, K; Shimizugawa, Y; Toyoda, N; Matsui, S; Yamada, I; Tsubakino, H; Matsuo, J

    2003-01-01

    Diamond-like carbon (DLC) film deposited using C sub 6 sub 0 vapor with simultaneous irradiation of an Ar cluster ion beam was characterized by a near edge X-ray absorption fine structure (NEXAFS), in order to optimize the hard DLC film deposition conditions. Contents of sp sup 2 orbitals in the films, which were estimated from NEXAFS spectra, are 30% lower than that of a conventional DLC film deposited by a RF plasma method. Those contents were obtained under the flux ratio of the C sub 6 sub 0 molecules to the Ar cluster ions to range from 1 to 20, at 5keV of Ar cluster ion acceleration energy. Average hardness of the films was 50 GPa under these flux ratios. This hardness was three times higher than that of a conventional DLC film. Furthermore, the lowest sp sup 2 content and above-mentioned high hardness were obtained at room temperature of the substrate when the depositions were performed in the range of the substrate temperature from room temperature to 250degC. (author)

  10. Cross-sections of large-angle hadron production in proton- and pion-nucleus interactions VI: carbon nuclei and beam momenta from ±3 GeV/c to ±15 GeV/c

    CERN Document Server

    Bolshakova, A; Chelkov, G; Dedovitch, D; Elagin, A; Emelyanov, D; Gostkin, M; Guskov, A; Kroumchtein, Z; Nefedov, Yu; Nikolaev, K; Zhemchugov, A; Dydak, F; Wotschack, J; De Min, A; Ammosov, V; Gapienko, V; Koreshev, V; Semak, A; Sviridov, Yu; Usenko, E; Zaets, V

    2010-01-01

    We report on double-differential inclusive cross-sections of the production of secondary protons, charged pions, and deuterons, in the interactions with a 5% nuclear interaction length thick stationary carbon target, of proton and pion beams with momentum from ±3 GeV/c to ±15 GeV/c. Results are given for secondary particles with production angles between 20 and 125 degrees. Cross-sections on carbon nuclei are compared with cross-sections on beryllium, copper, tantalum and lead nuclei.

  11. Carbon supported nanoparticles Pt Ru (Pt Ru/C electrocatalysts) prepared using electron beam irradiation; Preparacao de nanoparticulas de PtRu suportadas em carbono (eletrocatalisadores PtRu/C) utilizando feixe de eletrons

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Dionisio F. da; Oliveira Neto, Almir; Pino, Eddy S.; Linardi, Marcelo; Spinace, Estevam V. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Programa de Celulas a Combustivel], e-mail: espinace@ipen.br, e-mail: dfsilva@ipen.br

    2006-07-01

    Carbon-supported Pt Ru (electrocatalysts PtRu/C nanoparticles) were prepared submitting a water/ethylene glycol mixture containing Pt(IV) and Ru(III) ions and the carbon support to electron beam irradiation. The PtRu/C electrocatalysts were characterized by EDX, XRD and cyclic voltammetry and tested for methanol electro-oxidation aiming fuel cell application. The obtained PtRu/C electrocatalysts were more active for methanol electro-oxidation than the commercial PtRu/C ETEK electrocatalyst at ambient temperature. (author)

  12. Experimental Research on Reinforcing Damaged Reinforced Concrete Beams with Carbon Fiber Reinforced Plastics%碳纤维加固二次受力梁斜截面抗剪的试验研究

    Institute of Scientific and Technical Information of China (English)

    张国栋; 朱暾; 丁红瑞

    2001-01-01

    通过4根损伤的钢筋混凝土矩形简支梁的抗剪试验,对用CFRP(CarbonFiberReinforcedPlastics)补强二次受力钢筋混凝土梁斜截面强度的力学性能进行了试验研究.研究表明,用CFRP补强钢筋混凝土梁斜截面强度效果良好.%Through shear tests of four damaged rectangular cross-sectionbeams with simple supports,the strength of the inclined section of the beams reinforced with carbon fiber reinforced plastics(CFRP)is studied experimentally.The experimental results show that the effect of CFRP on beams' strengths is farourable.

  13. 碳纤维布加固锈蚀钢筋混凝土梁的疲劳性能试验%FATIGUE PERFORMANCE OF CORRODED RC BEAMS STRENGTHENED WITH CARBON FIBER COMPOSITE SHEETS

    Institute of Scientific and Technical Information of China (English)

    宋力; 张伟平

    2009-01-01

    完成了粘贴碳纤维布加固锈蚀钢筋混凝土梁的疲劳试验.试验结果表明,碳纤维布加固可以明显提高梁的疲劳寿命,减小梁的变形,提高梁的疲劳抗裂性能.因此,粘贴碳纤维布可以较大提高锈蚀钢筋混凝土梁的疲劳性能,延长锈蚀钢筋混凝土结构的使用寿命,为碳纤维布加固锈蚀钢筋混凝土结构的长期疲劳性能研究提供了试验依据.%Tests,including two corroded reinforced concrete(RC)beams strengthened with carbon fiber composite sheets and one corroded RC beams,were carried out under fatigue loadings.It is found that the fa-tigue life of beams strengthened with csrbon fiber composite sheets is greatly improved,and fatigue delforma-tion is decreased,and performance of anti-crack is obviously improved.Thus,after stuengthening with exter-ally bonded carbon fiber composite sheets,the flexural fatigue behavior of a corroded RC beam may be con-siderably improveded,the fatigue life of corrosion RC structures may be obviously increased.It sets up the test-base for the study of long-term performance of corroded RC beam reinforced with carbon fiber composite she-ets.

  14. Beam line to S155

    CERN Multimedia

    1977-01-01

    The experiment S155 was designed by the Orsay (CSNM-CNRS) Collaboration to observe the properties of exotic light nuclei. It was installed in the PS neutrino tunnel. The photo shows a mass spectrometer (in the background) on line with the PS proton beam which arrives (bottom, right) from the fast extraction FE74. Roger Fergeau stands on the left. The alkaline isotopes produced in the carbon-uranium target heated at 2000°C were swiftly extracted, mass separated, and brought to a detector behind the shielding. Sodium 34 (11 protons and 23 neutrons) was observed and its half-life of only 5 ms was measured. The excited levels 2+ of Magnesium 30 and Magnesium 32 (Sodium descendants) were localised, and the magic number 20 was found to vanish. Thus, the discovery made earlier for Sodium 30 and Sodium 32, with the same apparatus, was confirmed. (See also photo 7706511.)

  15. Absolute quantitation of iodine-123 epidepride kinetics using single-photon emission tomography: comparison with carbon-11 epidepride and positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, P. [CEA, 91 - Orsay (France). Service Hospitalier Frederic Joliot; Hospital Garcia de Orta, Servico de Medicina Nuclear, Pragal, Almada (Portugal); Ribeiro, M.J. [CEA, 91 - Orsay (France). Service Hospitalier Frederic Joliot; Servico de Biofisica, IBILI, Faculdade de Medicina de Coimbra (Portugal); Bottlaender, M.; Loc' h, C.; Langer, O.; Strul, D.; Maziere, B.; Bendriem, B. [CEA, 91 - Orsay (France). Service Hospitalier Frederic Joliot; Hugonnard, P.; Grangeat, P. [CEA Centre d' Etudes Nucleaires de Grenoble, 38 (France). Lab. d' Electronique de Technologie et d' Instrumentation

    1999-12-01

    Epidepride labelled with iodine-123 is a suitable probe for the in vivo imaging of striatal and extrastriatal dopamine D{sub 2} receptors using single-photon emission tomography (SPET). Recently, this molecule has also been labelled with carbon-11. The goal of this work was to develop a method allowing the in vivo quantification of radioactivity uptake in baboon brain using SPET and to validate it using positron emission tomography (PET). SPET studies were performed in Papio anubis baboons using {sup 123}I-epidepride. Emission and transmission measurements were acquired on a dual-headed system with variable head angulation and low-energy ultra-high resolution (LEUHR) collimation. The imaging protocol consisted of one transmission measurement (24 min, heads at 90 ), obtained with two sliding line sources of gadolinium-153 prior to injection of 0.21-0.46 GBq of {sup 123}I-epidepride, and 12 emission measurements starting 5 min post injection. For scatter correction (SC) we used a dual-window method adapted to {sup 123}I. Collimator blurring correction (CBC) was done by deconvolution in Fourier space and attenuation correction (AT) was applied on a preliminary (CBC) filtered back-projection reconstruction using 12 iterations of a preconditioned, regularized minimal residual algorithm. For each reconstruction, a calibration factor was derived from a uniform cylinder filled with a {sup 123}I solution of a known radioactivity concentration. Calibration and baboon images were systematically built with the same reconstruction parameters. Uncorrected (UNC) and (AT), (SC+AT) and (SC+CBC+AT) corrected images were compared. PET acquisitions using 0.11-0.44 GBq of {sup 11}C-epidepride were performed on the same baboons and used as a reference. The radioactive concentrations expressed in percent of the injected dose per 100 ml (%ID/100 ml) obtained after (SC+CBC+AT) in SPET are in good agreement with those obtained with PET and {sup 11}C-epidepride. A method for the in vivo

  16. Non-invasive estimation of myocardial efficiency using positron emission tomography and carbon-11 acetate--comparison between the normal and failing human heart.

    Science.gov (United States)

    Bengel, F M; Permanetter, B; Ungerer, M; Nekolla, S; Schwaiger, M

    2000-03-01

    The clearance kinetics of carbon-11 acetate, assessed by positron emission tomography (PET), can be combined with measurements of ventricular function for non-invasive estimation of myocardial oxygen consumption and efficiency. In the present study, this approach was applied to gain further insights into alterations in the failing heart by comparison with results obtained in normals. We studied ten patients with idiopathic dilated cardiomyopathy (DCM) and 11 healthy normals by dynamic PET with 11C-acetate and either tomographic radionuclide ventriculography or cine magnetic resonance imaging. A "stroke work index" (SWI) was calculated by: SWI = systolic blood pressure x stroke volume/body surface area. To estimate myocardial efficiency, a "work-metabolic index" (WMI) was then obtained as follows: WMI = SWI x heart rate/k(mono), where k(mono) is the washout constant for 11C-acetate derived from monoexponential fitting. In DCM patients, left ventricular ejection fraction was 19%+/-10% and end-diastolic volume was 92+/-28 ml/m2 (vs 64%+/-7% and 55+/-8 ml/m2 in normals, PSWI (1674+/-761 vs 4736+/-895 mmHg x ml/m2; P<0.001) and the WMI as an estimate of efficiency (2.98+/-1.30 vs 6.20+/-2.25 x 10(6) mmHg x ml/m2; P<0.001) were lower in DCM patients, too. Overall, the WMI correlated positively with ejection parameters (r=0.73, P<0.001 for ejection fraction; r=0.93, P<0.001 for stroke volume), and inversely with systemic vascular resistance (r=-0.77; P<0.001). There was a weak positive correlation between WMI and end-diastolic volume in normals (r=0.45; P=0.17), while in DCM patients, a non-significant negative correlation coefficient (r=-0.21; P=0.57) was obtained. In conclusion non-invasive estimates of oxygen consumption and efficiency in the failing heart were reduced compared with those in normals. Estimates of efficiency increased with increasing contractile performance, and decreased with increasing ventricular afterload. In contrast to normals, the failing heart

  17. Absolute quantitation of iodine-123 epidepride kinetics using single-photon emission tomography: comparison with carbon-11 epidepride and positron emission tomography.

    Science.gov (United States)

    Almeida, P; Ribeiro, M J; Bottlaender, M; Loc'h, C; Langer, O; Strul, D; Hugonnard, P; Grangeat, P; Mazière, B; Bendriem, B

    1999-12-01

    Epidepride labelled with iodine-123 is a suitable probe for the in vivo imaging of striatal and extrastriatal dopamine D2 receptors using single-photon emission tomography (SPET). Recently, this molecule has also been labelled with carbon-11. The goal of this work was to develop a method allowing the in vivo quantification of radioactivity uptake in baboon brain using SPET and to validate it using positron emission tomography (PET). SPET studies were performed in Papio anubis baboons using 123I-epidepride. Emission and transmission measurements were acquired on a dual-headed system with variable head angulation and low-energy ultra-high resolution (LEUHR) collimation. The imaging protocol consisted of one transmission measurement (24 min, heads at 90 degrees), obtained with two sliding line sources of gadolinium-153 prior to injection of 0.21-0.46 GBq of 123I-epidepride, and 12 emission measurements starting 5 min post injection. For scatter correction (SC) we used a dual-window method adapted to 123I. Collimator blurring correction (CBC) was done by deconvolution in Fourier space and attenuation correction (AT) was applied on a preliminary (CBC) filtered back-projection reconstruction using 12 iterations of a preconditioned, regularized minimal residual algorithm. For each reconstruction, a calibration factor was derived from a uniform cylinder filled with a 123I solution of a known radioactivity concentration. Calibration and baboon images were systematically built with the same reconstruction parameters. Uncorrected (UNC) and (AT), (SC + AT) and (SC + CBC + AT) corrected images were compared. PET acquisitions using 0.11-0.44 GBq of 11C-epidepride were performed on the same baboons and used as a reference. The radioactive concentrations expressed in percent of the injected dose per 100 ml (% ID/100 ml) obtained after (SC + CBC + AT) in SPET are in good agreement with those obtained with PET and 11C-epidepride. A method for the in vivo absolute quantitation of 123

  18. Absolute quantitation of iodine-123 epidepride kinetics using single-photon emission tomography: comparison with carbon-11 epidepride and positron emission tomography

    International Nuclear Information System (INIS)

    Epidepride labelled with iodine-123 is a suitable probe for the in vivo imaging of striatal and extrastriatal dopamine D2 receptors using single-photon emission tomography (SPET). Recently, this molecule has also been labelled with carbon-11. The goal of this work was to develop a method allowing the in vivo quantification of radioactivity uptake in baboon brain using SPET and to validate it using positron emission tomography (PET). SPET studies were performed in Papio anubis baboons using 123I-epidepride. Emission and transmission measurements were acquired on a dual-headed system with variable head angulation and low-energy ultra-high resolution (LEUHR) collimation. The imaging protocol consisted of one transmission measurement (24 min, heads at 90 ), obtained with two sliding line sources of gadolinium-153 prior to injection of 0.21-0.46 GBq of 123I-epidepride, and 12 emission measurements starting 5 min post injection. For scatter correction (SC) we used a dual-window method adapted to 123I. Collimator blurring correction (CBC) was done by deconvolution in Fourier space and attenuation correction (AT) was applied on a preliminary (CBC) filtered back-projection reconstruction using 12 iterations of a preconditioned, regularized minimal residual algorithm. For each reconstruction, a calibration factor was derived from a uniform cylinder filled with a 123I solution of a known radioactivity concentration. Calibration and baboon images were systematically built with the same reconstruction parameters. Uncorrected (UNC) and (AT), (SC+AT) and (SC+CBC+AT) corrected images were compared. PET acquisitions using 0.11-0.44 GBq of 11C-epidepride were performed on the same baboons and used as a reference. The radioactive concentrations expressed in percent of the injected dose per 100 ml (%ID/100 ml) obtained after (SC+CBC+AT) in SPET are in good agreement with those obtained with PET and 11C-epidepride. A method for the in vivo absolute quantitation of 123I

  19. Comparative study of the pharmacokinetics of carbon tetrachloride in the rat following repeated inhalation exposures of 8 and 11.5 hr/day

    International Nuclear Information System (INIS)

    To evaluate whether exposure to inhaled vapors for periods longer than 8 hr/day could affect the rates and routes of elimination, male Sprague-Dawley rats were repeatedly exposed to 100 ppm of radiolabeled carbon tetrachloride (14CCl4) in a closed-loop chamber. One group was exposed for 8 hr/day for 5 days and another group for 11.5 hr/day for 4 days. Two other groups were exposed for either 8 hr/day for 10 of 12 consecutive days or 11.5 hr/day for 7 of 10 days. The elimination of 14C activity was measured in the expired air, urine, and feces for up to 100 hr following exposure and the pharmacokinetic parameters were determined. Following 2 weeks of exposure to the 8-hr/day schedule, 14CCl4 in the breath and 14C activity in the feces comprised 45 and 48% of the total 14C excreted, respectively. Following 2 weeks of exposure to the 11.5-hr/day schedule, the values were 32 and 62%, respectively, indicating that repeated exposure to the longer schedule altered the route of elimination of CCl4. Regardless of the period of exposure, less than 8% of the inhaled 14CCl4 was excreted in the urine and less than 2% was exhaled in the breath as the 14CO2 metabolite. Approximately 97-98% of the 14C activity in the expired air was 14CCl4. The quantities of 14C noted in the feces and urine suggest that more than 60% of the inhaled CCl4 was metabolized. Elimination of 14CCl4 and 14CO2 in the breath followed a two-compartment, first-order pharmacokinetic model (r2 = 0.98). For rats exposed 8 hr/day and 11.5 hr/day for 2 weeks, the average half-lives for elimination of 14CCl4 in the breath for the fast (alpha) and slow (beta) phases averaged 96 and 455 min, and 89 and 568 min, respectively. The average alpha and beta half-lives for elimination of 14CO2 in the breath

  20. SU-E-E-11: Novel Matching Module for Respiration-Gated Motion Tumor of Cone-Beam Computed Tomography (CBCT) to 4DCT

    International Nuclear Information System (INIS)

    Purpose: Four dimensional computed tomography (4DCT) scans reliably record whole respiratory phase and generate internal target volumes (ITV) for radiotherapy planning. However, image guiding with cone-beam computed tomography (CBCT) cannot acquire all or specific respiratory phases. This study was designed to investigate the correlation between average CT and Maximum Intensity Projection (MIP) from 4DCT and CBCT. Methods: Retrospective respiratory gating were performed by GE Discovery CT590 RT. 4DCT and CBCT data from CRIS Dynamic Thorax Phantom with simulated breathing mode were analyzed. The lung tissue equivalent material encompassed 3 cm sphere tissue equivalent material. Simulated breathing cycle period was set as 4 seconds, 5 seconds and 6 seconds for representing variation of patient breathing cycle time, and the sphere material moved toward inferior and superior direction with 1 cm amplitude simulating lung tumor motion during respiration. Results: Under lung window, the volume ratio of CBCT scans to ITVs derived from 10 phases average scans was 1.00 ± 0.02, and 1.03 ± 0.03 for ratio of CBCT scans to MIP scans. Under abdomen window, the ratio of CBCT scans to ITVs derived from 10 phases average scans was 0.39 ± 0.06, and 0.06 ± 0.00 for ratio of CBCT scans to MIP scans. There was a significant difference between lung window Result and abdomen window Result. For reducing image guiding uncertainty, CBCT window was set with width 500 and level-250. The ratio of CBCT scans to ITVs derived from 4 phases average scans with abdomen window was 1.19 ± 0.02, and 1.06 ± 0.01 for ratio of CBCT to MIP scans. Conclusion: CBCT images with suitable window width and level can efficiently reduce image guiding uncertainty for patient with mobile tumor. By our setting, we can match motion tumor to gating tumor location on planning CT more accurately neglecting other motion artifacts during CBCT scans

  1. Crossed-beam reaction of carbon atoms with hydrocarbon molecules. V. Chemical dynamics of n-C4H3 formation from reaction of C(3Pj) with allene, H2CCCH2(X 1A1)

    Science.gov (United States)

    Kaiser, R. I.; Mebel, A. M.; Chang, A. H. H.; Lin, S. H.; Lee, Y. T.

    1999-06-01

    The crossed molecular beams technique was employed to investigate the reaction between ground state carbon atoms, C(3Pj), and allene, H2CCCH2(X 1A1), at two averaged collision energies of 19.6 and 38.8 kJ mol-1. Product angular distributions and time-of-flight spectra of C4H3 were recorded. Forward-convolution fitting of the data yields weakly polarized center-of-mass angular flux distributions isotropic at lower, but forward scattered with respect to the carbon beam at a higher collision energy. The maximum translational energy release and the angular distributions combined with ab initio and RRKM calculations are consistent with the formation of the n-C4H3 radical in its electronic ground state. The channel to the i-C4H3 isomer contributes less than 1.5%. Reaction dynamics inferred from the experimental data indicate that the carbon atom attacks the π-orbitals of the allenic carbon-carbon double bond barrierless via a loose, reactant-like transition state located at the centrifugal barrier. The initially formed cyclopropylidene derivative rotates in a plane almost perpendicular to the total angular momentum vector around its C-axis and undergoes ring opening to triplet butatriene. At higher collision energy, the butatriene complex decomposes within 0.6 ps via hydrogen emission to form the n-C4H3 isomer and atomic hydrogen through an exit transition state located 9.2 kJ mol-1 above the products. The explicit identification of the n-C4H3 radical under single collision represents a further example of a carbon-hydrogen exchange in reactions of ground state carbon atoms with unsaturated hydrocarbons. This channel opens a barrierless route to synthesize extremely reactive hydrocarbon radicals in combustion processes, interstellar chemistry, and hydrocarbon-rich atmospheres of Jupiter, Saturn, Titan, as well as Triton.

  2. Realization of an apparatus for the synthesis and detection of carbon 11 labelled fatty acids and of a data acquisition system for the study of the myocardial methabolism of radiopharmaceuticals

    International Nuclear Information System (INIS)

    This thesis describes the study and the realization of an apparatus to synthesize fatty acids labelled with carbon 11, a radioactive isotope with an half-life of 20.38 minutes. A system of gamma-ray detection with data processing designed for the study of the myocardiac metabolism of radiopharmaceuticals using isolated rat hearts as experimental models. The synthesis of carbon 11 labelled fatty acids required a preliminary study of the manufacture of this isotope at the synchrocyclotron of the I.P.N. (Lyon). The method chosen is the nuclear reaction (d,xn) with naturally occurring boron trioxide as the target. The apparatus was designed so as extract carbon 11 from the target in the form of 11CO2 which can then be used in the synthesis of carbon 11 labelled hexadecanoique, heptadecanoic and beta-methyl hexadecanoic acids. The time scale of this synthesis must be compatible with the short half-like of the isotope. In order to study these compounds 'in vivo' on the experimental model of isolated rat hearts, a system of detection, which functions either in a simple gamma mode or in a gamma-gamma coincidence mode, was developed. This apparatus can attain a rate of approximately 50 000 counts/sec. per channel, thus it is possible to obtain information about rapid phases of metabolism with a satisfactory statistical precision. Moreover the spectral analysis of the gamma-ray permits the simultaneous detection of different radioisotopes. Hence it was possible to compare the behaviour of carbon 11 labelled fatty acids with homologous molecules marked with iodine 123. The analysis of the experimental results was achieved witha computer based on an I.B.M. compatible PC-XT. The essential parts of this system are a data-acquisition card for the PC, code for the acquisition and the data processing

  3. Nonlinear FE Analysis of Reinforced H.S. Concrete Continuous Beam Strengthened with CFRP Sheet

    Directory of Open Access Journals (Sweden)

    Majid Mohammed Ali Kadhim

    2011-01-01

    Full Text Available This paper is focused on the nonlinear finite element analysis of the reinforced high strength concrete continuous beam strength with carbon fiber reinforced polymer sheet. Three full scale continuous beams are analyzed under two points load; the data of analysis are compared with the experimental data provided by Akbarzadeh and Maghsoudi [1]. ANSYS V.11 program is used in FE analysis, the results obtained from analysis give good agreement with experimental result when compared load-deflection responses, ultimate strength, and the crack patterns. The results showed that with increasing the number of layers, the ultimate strength of beams are increase by amount reached (14% for each layer. The failure mode different by increasing number of CFRP sheet layers when the beam strengthened by one layer of CFRP sheet failed by tensile rupture of CFRP sheet, and beam strengthened by more than one layer failed by intermediate crack (IC debonding of CFRP sheet.

  4. Reconstruction of the carbon isotopic composition of methane over the last 50 yr based on firn air measurements at 11 polar sites

    Directory of Open Access Journals (Sweden)

    C. J. Sapart

    2012-04-01

    Full Text Available Methane is a strong greenhouse gas and large uncertainties exist concerning the future evolution of its atmospheric abundance. Analyzing methane atmospheric mixing and stable isotope ratios in air trapped in polar ice sheets helps reconstructing the evolution of its sources and sinks in the past. This is important to improve predictions of atmospheric CH4 mixing ratios in the future under the influence of a changing climate. We present an attempt to reconcile methane carbon isotope records from 11 firn sites from both Greenland and Antarctica to reconstruct a consistent δ13C(CH4 history over the last 50 yr. In the firn, the atmospheric signal is altered mainly by diffusion and gravitation. These processes are taken into account by firn transport models. We show that isotope reconstructions from individual sites are not always mutually consistent among the different sites. Therefore we apply for the first time a multisite isotope inversion to reconstruct an atmospheric isotope history that is constrained by all individual sites, generating a multisite "best-estimate" scenario. This scenario is compared to ice core data, atmospheric air archive results and direct atmospheric monitoring data.

  5. Bessel Beams

    OpenAIRE

    McDonald, Kirk T

    2000-01-01

    Scalar Bessel beams are derived both via the wave equation and via diffraction theory. While such beams have a group velocity that exceeds the speed of light, this is a manifestation of the "scissors paradox" of special relativty. The signal velocity of a modulated Bessel beam is less than the speed of light. Forms of Bessel beams that satisfy Maxwell's equations are also given.

  6. Evaluation of nuclear reaction cross-sections and fragment yields in carbon beams using the SHIELD-HIT Monte Carlo code. Comparison with experiments

    International Nuclear Information System (INIS)

    In light ion therapy, the knowledge of the spectra of both primary and secondary particles in the target volume is needed in order to accurately describe the treatment. The transport of ions in matter is complex and comprises both atomic and nuclear processes involving primary and secondary ions produced in the cascade of events. One of the critical issues in the simulation of ion transport is the modeling of inelastic nuclear reaction processes, in which projectile nuclei interact with target nuclei and give rise to nuclear fragments. In the Monte Carlo code SHIELD-HIT, inelastic nuclear reactions are described by the Many Stage Dynamical Model (MSDM), which includes models for the different stages of the interaction process. In this work, the capability of SHIELD-HIT to simulate the nuclear fragmentation of carbon ions in tissue-like materials was studied. The value of the parameter κ, which determines the so-called freeze-out volume in the Fermi break-up stage of the nuclear interaction process, was adjusted in order to achieve better agreement with experimental data. In this paper, results are shown both with the default value κ = 1 and the modified value κ = 10 which resulted in the best overall agreement. Comparisons with published experimental data were made in terms of total and partial charge-changing cross-sections generated by the MSDM, as well as integral and differential fragment yields simulated by SHIELD-HIT in intermediate and thick water targets irradiated with a beam of 400 MeV u−112C ions. Better agreement with the experimental data was in general obtained with the modified parameter value (κ = 10), both on the level of partial charge-changing cross-sections and fragment yields. (paper)

  7. Carbon ion beam triggers both caspase-dependent and caspase-independent pathway of apoptosis in HeLa and status of PARP-1 controls intensity of apoptosis.

    Science.gov (United States)

    Ghorai, Atanu; Sarma, Asitikantha; Bhattacharyya, Nitai P; Ghosh, Utpal

    2015-04-01

    High linear energy transfer (LET) carbon ion beam (CIB) is becoming very promising tool for various cancer treatments and is more efficient than conventional low LET gamma or X-rays to kill malignant or radio-resistant cells, although detailed mechanism of cell death is still unknown. Poly (ADP-ribose) polymerase-1 (PARP-1) is a key player in DNA repair and its inhibitors are well-known as radio-sensitizer for low LET radiation. The objective of our study was to find mechanism(s) of induction of apoptosis by CIB and role of PARP-1 in CIB-induced apoptosis. We observed overall higher apoptosis in PARP-1 knocked down HeLa cells (HsiI) compared with negative control H-vector cells after irradiation with CIB (0-4 Gy). CIB activated both intrinsic and extrinsic pathways of apoptosis via caspase-9 and caspase-8 activation respectively, followed by caspase-3 activation, apoptotic body, nucleosomal ladder formation and sub-G1 accumulation. Apoptosis inducing factor translocation into nucleus in H-vector but not in HsiI cells after CIB irradiation contributed caspase-independent apoptosis. Higher p53 expression was observed in HsiI cells compared with H-vector after exposure with CIB. Notably, we observed about 37 % fall of mitochondrial membrane potential, activation of caspase-9 and caspase-3 and mild activation of caspase-8 without any detectable apoptotic body formation in un-irradiated HsiI cells. We conclude that reduction of PARP-1 expression activates apoptotic signals via intrinsic and extrinsic pathways in un-irradiated cells. CIB irradiation further intensified both intrinsic and extrinsic pathways of apoptosis synergistically along with up-regulation of p53 in HsiI cells resulting overall higher apoptosis in HsiI than H-vector.

  8. Ion-beam technologies

    Energy Technology Data Exchange (ETDEWEB)

    Fenske, G.R. [Argonne National Lab., IL (United States)

    1993-01-01

    This compilation of figures and diagrams reviews processes for depositing diamond/diamond-like carbon films. Processes addressed are chemical vapor deposition (HFCVD, PACVD, etc.), plasma vapor deposition (plasma sputtering, ion beam sputtering, evaporation, etc.), low-energy ion implantation, and hybrid processes (biased sputtering, IBAD, biased HFCVD, etc.). The tribological performance of coatings produced by different means is discussed.

  9. Combined δ11B, δ13C, and δ18O analyses of coccolithophore calcite constrains the response of coccolith vesicle carbonate chemistry to CO2-induced ocean acidification

    Science.gov (United States)

    Liu, Yi-Wei; Tripati, Robert; Aciego, Sarah; Gilmore, Rosaleen; Ries, Justin

    2016-04-01

    Coccolithophorid algae play a central role in the biological carbon pump, oceanic carbon sequestration, and in marine food webs. It is therefore important to understand the potential impacts of CO2-induced ocean acidification on these organisms. Differences in the regulation of carbonate chemistry, pH, and carbon sources of the intracellular compartments where coccolith formation occurs may underlie the diverse calcification and growth responses to acidified seawater observed in prior experiments. Here we measured stable isotopes of boron (δ11B), carbon (δ13C) and oxygen (δ18O) within coccolith calcite, and δ13C of algal tissue to constrain carbonate system parameters in two strains of Pleurochrysis carterae (P. carterae). The two strains were cultured under variable pCO2, with water temperature, salinity, dissolved inorganic carbon (DIC), and alkalinity monitored. Notably, PIC, POC, and PIC/POC ratio did not vary across treatments, indicating that P. carterae is able to calcify and photosynthesize at relatively constant rates irrespective of pCO2 treatment. The δ11B data indicate that mean pH at the site of coccolith formation did not vary significantly in response to elevated CO2. These results suggest that P. carterae regulates calcifying vesicle pH, even amidst changes in external seawater pH. Furthermore, δ13C and δ18O data suggest that P. carterae may utilize carbon from a single internal DIC pool for both calcification and photosynthesis, and that a greater proportion of dissolved CO2 relative to HCO3- enters the internal DIC pool under acidified conditions. These results suggest that P. carterae is able to calcifyand photosynthesize at relatively constant rates across pCO2 treatments by maintaining pH homeostasis at their site of calcification and utilizing a greater proportion of aqueous CO2.

  10. 预拉碳纤维布加固持荷混凝土梁受力性能分析%Mechanical Behavior of Pre-loaded Reinforced Concrete Beams Strengthened by Pre-tensioned Carbon Fiber Composite Sheets

    Institute of Scientific and Technical Information of China (English)

    高鹏; 顾祥林

    2009-01-01

    According to the characteristic of pre-loaded reinforced concrete beams strengthened by pre-tensioned carbon fiber composite sheets, a suitable finite element model and corresponding calculation steps were proposed. The method was verified by the testing results of two groups of strengthened beam specimens. Comparison between simulation and testing results shows that the proposed method is a precise numerical tool. Further parameter analysis using the proposed method shows that the bearing capacity of a strengthened beam might be notably reduced if the pre-load applied on the beam is larger than 40% of the initial bearing capacity of the beam, the strength of carbon fiber composite sheets can be fully used by using pre-tensioning technique,and the negative influence of the pre-load on the bending behavior of a strengthened beam can be made up when the pre-strain of carbon fiber composite sheets is between 0.003~0.004.%根据预张拉碳纤维布加固持荷钢筋混凝土梁受力特点,采用商业软件建立有限元模型对梁加固和受荷全过程进行模拟和分析.对两组试验梁的模拟计算结果显示,有限元方法有较好的精度.试验和进一步的有限元数值模拟分析结果表明,当构件上的持荷水平超过未加固构件承载力的40%时,持荷会降低加固构件的承载力;采用预张拉加固方法可充分发挥碳纤维布的强度,当碳纤维布中的有效预拉应变达0.003~0.004时,可消除持荷对加固梁受力性能的影响.

  11. Microstructure and mechanical properties of high-strength TC11 titanium alloy joints welded by laser beam%TC11高强钛合金激光焊接接头的显微组织与力学性能

    Institute of Scientific and Technical Information of China (English)

    虞鸿江; 范如意; 黄坚; 潘丽华; 王勇

    2015-01-01

    采用光纤激光进行TC11钛合金对接焊接,分析焊接接头的显微组织和力学性能。结果表明,TC11钛合金焊缝为α′马氏体组织,从母材至熔合线组织由α+β逐渐向α′转变;随着热输入量的增加,焊缝柱状晶尺寸变大,马氏体分布更加密集交错,同时热影响区宽度增加,粗晶区晶粒尺寸变大;2 mm厚TC11钛合金在焊接速度2.0 m/min、激光功率2.8~3.2 kW的工艺参数下得到的焊缝成形良好;焊缝硬度高于母材硬度,并随热输入量的增加而增大;焊接接头抗拉强度达到母材的97%以上,塑性明显下降,低于母材的50%,焊缝断口形貌为低塑性沿晶断裂特征。%The titanium alloy TC11 was welded by fiber laser beam, the microstructure and mechanical properties of the laser welded TC11 joints with different welding parameters were studied. The results show that the microstructure of weld metal consists ofα′ martensite.From the base metal to fusion line, the microstructure evolves fromα+β phase toα′ phase. With increasing the heat input, the size of columnar dendrites increases, the distribution ofα′ martensite becomes more dispersive, the width of HAZ and grain size in coarse grain zone increase. Under the welding speed of 2.0 m/min and laser power of 2.8−3.2 kW, the sound welds of 2 mm thick TC11 alloy were obtained. The hardness of the weld increases with increasing the heat input. The tensile strength of welded joints reaches at least 97% of that of the base metal, while the plasticity decreases significantly. The fracture topography of welded joints shows brittle fracture character.

  12. Carbon Dioxide, Hydrographic, and Chemical Data Obtained During the R/V Ronald H. Brown Repeat Hydrography Cruise in the Atlantic Ocean: CLIVAR CO2 Section A16S_2005 (11 January - 24 February, 2005)

    Energy Technology Data Exchange (ETDEWEB)

    Kozyr, Alex [Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States). Carbon Dioxide Information Analysis Center

    2006-08-30

    This report presents methods, and analytical and quality control procedures for salinity, oxygen, nutrient, inorganic carbon, organic carbon, chlorofluorocarbon (CFC), and bomb 14C system parameters performed during the A16S_2005 cruise, which took place from January 11 to February 24, 2005, aboard research vessel (R/V) Ronald H. Brown under the auspices of the National Oceanic and Atmospheric Administration (NOAA). The R/V Ronald H. Brown departed Punta Arenas, Chile, on January 11, 2005, and ended its cruise in Fortaleza, Brazil, on February 24, 2005. The research conducted was one of a series of repeat hydrography sections jointly funded by NOAA and the National Science Foundation as part of the CLIVAR/CO2/repeat hydrography/tracer program. Samples were taken from 36 depths at 121 stations. The data presented in this report include the analyses of water samples for total inorganic carbon (TCO2), fugacity of CO2 (fCO2), total alkalinity (TALK), pH, dissolved organic carbon (DOC), CFC, 14C, hydrographic, and other chemical measurements. The R/V Ronald H. Brown A16S_2005 data set is available free of charge as a numeric data package (NDP) from the Carbon Dioxide Information Analysis Center (CDIAC). The NDP consists of the oceanographic data files and this printed documentation, which describes the procedures and methods used to obtain the data.

  13. Discovery of water vapour in the carbon star V Cygni from observations with Herschel/HIFI

    NARCIS (Netherlands)

    D.A. Neufeld; E. González-Alfonso; G. Melnick; M. Pułecka; M. Schmidt; R. Szczerba; V. Bujarrabal; J. Alcolea; J. Cernicharo; L. Decin; C. Dominik; K. Justtanont; A. de Koter; A.P. Marston; K. Menten; H. Olofsson; P. Planesas; F.L. Schöier; D. Teyssier; L.B.F.M. Waters; K. Edwards; C. McCoey; R. Shipman; W. Jellema; T. de Graauw; V. Ossenkopf; R. Schieder; S. Philipp

    2010-01-01

    We report the discovery of water vapour toward the carbon star V Cygni. We have used Herschel's HIFI instrument, in dual beam switch mode, to observe the 1(11)-0(00) para-water transition at 1113.3430 GHz in the upper sideband of the Band 4b receiver. The observed spectral line profile is nearly par

  14. Carbon Fiber Laminate Strengthened RC Beams Subjected to Fatigue Loading at Elevated Temperature%温度升高对碳纤维薄板增强RC梁疲劳性能的影响

    Institute of Scientific and Technical Information of China (English)

    周芝林; 黄培彦; 郭馨艳

    2008-01-01

    The static and fatigue tests under cyclic bending loads at different ambient temperatures of 20 ℃ and 80℃ are carried out to investigate the fatigue behavior of the reinforced concrete(RC) beams strengthened with'carbon fi-ber laminates(CFLs). The failure modes of the strengthened beams include CFLs debonded near the mid-span and steel rebar yielded or broken. S-N curves of strengthened beams are developed according to the test results. The fa-tigue limit, load versus deflection curves and strain response of strengthened beams are obtained as well. The results show that the fatigue behaviors of the strengthened beams are not significantly influenced by the ambient tempera-tures (lower than 80℃) when the fatigue load levels equal 25.0 kN, 27.5 kN and 30.0 kN.%为了研究碳纤维薄板增强钢筋混凝土梁在不同温度下的疲劳性能,分别在20℃和80℃的温度条件下对26根增强梁进行了三点弯曲静载和疲劳试验.结果表明:当疲劳载荷水平为25.0 kN,27.5 kN和30.0 kN时,试件的S-N曲线、疲劳极限、破坏模式、挠度曲线和应变反映受环境温度的影响较小.

  15. Treatment of industrial effluents using electron beam accelerator and adsorption with activated carbon. A comparative study; Tratamento de efluentes industriais utilizando a radiacao ionizante de acelerador industrial de eletrons e por adsorcao com carvao ativado. Estudo comparativo

    Energy Technology Data Exchange (ETDEWEB)

    Las Casas, Alexandre

    2004-07-01

    Several methods are used In the pollutant removal from Industrial and domestic wastewater. However when the degradation of toxic organic pollutants, mainly the recalcitrant is objectified, the conventional treatments usually do not meet the desirable performance in the elimination or decrease the impact when the effluent are released to the environment what takes to the research of alternative methods that seek the improvement of the efficiency of the wastewater treatment systems jointly employees or separately. This work presents a study of degradation/removal of pollutants organic compounds comparing two methods using radiation from industrial electron beam and granular activated carbon (GAC). The removal efficiency of the pollutants was evaluated and it was verified that the efficiency of adsorption with activated carbon is similar to the radiation method. The obtained results allowed to evaluated the relative costs of these methods. (author)

  16. Beam - cavity interaction beam loading

    International Nuclear Information System (INIS)

    The interaction of a beam with a cavity and a generator in cyclic accelerators or storage rings is investigated. Application of Maxwell's equations together with the nonuniform boundary condition allows one to get an equivalent circuit for a beam-loaded cavity. The general equation for beam loading is obtained on the basis of the equivalent circuit, and the beam admittance is calculated. Formulas for power consumption by a beam-loaded cavity are derived, and the optimal tuning and coupling factor are analyzed. (author)

  17. A beam source model for scanned proton beams

    Science.gov (United States)

    Kimstrand, Peter; Traneus, Erik; Ahnesjö, Anders; Grusell, Erik; Glimelius, Bengt; Tilly, Nina

    2007-06-01

    A beam source model, i.e. a model for the initial phase space of the beam, for scanned proton beams has been developed. The beam source model is based on parameterized particle sources with characteristics found by fitting towards measured data per individual beam line. A specific aim for this beam source model is to make it applicable to the majority of the various proton beam systems currently available or under development, with the overall purpose to drive dose calculations in proton beam treatment planning. The proton beam phase space is characterized by an energy spectrum, radial and angular distributions and deflections for the non-modulated elementary pencil beam. The beam propagation through the scanning magnets is modelled by applying experimentally determined focal points for each scanning dimension. The radial and angular distribution parameters are deduced from measured two-dimensional fluence distributions of the elementary beam in air. The energy spectrum is extracted from a depth dose distribution for a fixed broad beam scan pattern measured in water. The impact of a multi-slab range shifter for energy modulation is calculated with an own Monte Carlo code taking multiple scattering, energy loss and straggling, non-elastic and elastic nuclear interactions in the slab assembly into account. Measurements for characterization and verification have been performed with the scanning proton beam system at The Svedberg Laboratory in Uppsala. Both in-air fluence patterns and dose points located in a water phantom were used. For verification, dose-in-water was calculated with the Monte Carlo code GEANT 3.21 instead of using a clinical dose engine with approximations of its own. For a set of four individual pencil beams, both with the full energy and range shifted, 96.5% (99.8%) of the tested dose points satisfied the 1%/1 mm (2%/2 mm) gamma criterion.

  18. Kevlar and Carbon Fiber Sheet Reinforced Soil Reinforced Concrete Beam Flexural Performance Test Inquiry%碳纤维布及芳纶布加固钢筋混土梁受弯性能试验探究

    Institute of Scientific and Technical Information of China (English)

    邝美玲

    2016-01-01

    在土木工程建设中,碳纤维布及芳纶布为钢筋混土构件带来了新的加固机遇,已成为工程施工中的实质性保障,占据着综合比例的重要地位。基于此,从钢筋混土梁入手,结合相关试验案例,重点分析碳纤维布及芳纶布加固钢筋混土梁受弯性能的优化举措,以供相关研究参考。%In the civil engineering construction,carbon fiber and Kevlar fiber cloth cloth reinforced concrete soil reinforcement member has brought new opportunities,construction has become a substantive guarantee,occupies an important position integrated scale.Based on this,the soil from reinforced concrete beams,combining relevant test case focuses on Kevlar Reinforced with carbon fiber sheet reinforced concrete and soil beam flexural performance optimization initiatives for research reference.

  19. Beam loading

    CERN Document Server

    Gamp, Alexander

    2013-01-01

    We begin by giving a description of the radio-frequency generator-cavity-beam coupled system in terms of basic quantities. Taking beam loading and cavity detuning into account, expressions for the cavity impedance as seen by the generator and as seen by the beam are derived. Subsequently methods of beam-loading compensation by cavity detuning, radio-frequency feedback and feedforward are described. Examples of digital radio-frequency phase and amplitude control for the special case of superconducting cavities are also given. Finally, a dedicated phase loop for damping synchrotron oscillations is discussed.

  20. Fiber-Matrix Interface Studies on Electron Beam Cured Composites

    Energy Technology Data Exchange (ETDEWEB)

    Drazel, L.T.; Janke, C.J.; Yarborough, K.D.

    1999-05-23

    The recently completed Department of Energy (DOE) and industry sponsored Cooperative Research and Development Agreement (CRADA) entitled, ''Electron Beam Curing of Polymer Matrix Composites,'' determined that the interlaminar shear strength properties of the best electron beam cured IM7/epoxy composites were 19-28% lower than autoclave cured IM7/epoxy composites (i.e. IM7/977-2 and IM7/977-3). Low interlaminar shear strength is widely acknowledged as the key barrier to the successful acceptance and implementation of electron beam cured composites in the aircraft/aerospace industry. The objective of this work was to improve the interlaminar shear strength properties of electron beam cured composites by formulating and evaluating several different fiber sizings or coating materials. The researchers have recently achieved some promising results by having discovered that the application of epoxy-based, electron beam compatible sizings or coatings onto surface-treated, unsized IM7 carbon fibers improved the composite interlaminar shear strength properties by as much as 55% versus composites fabricated from surface-treated, unsized IM7 fibers. In addition, by applying these same epoxy-based sizings or coatings onto surface-treated, unsized IM7 fibers it was possible to achieve an 11% increase in the composite interlaminar shear strength compared to composites made from surface-treated, GP-sized IM7 fibers. Work is continuing in this area of research to further improve these properties.

  1. THE MECHANICAL BEHAVIOR EXPERIMENT AND ANALYSIS OF CONTINUOUS BEAMS STRENGTHENED WITH CARBON FIBER REINFORCED POLYMER SHEETS%碳纤维布加固连续梁力学性能试验及分析

    Institute of Scientific and Technical Information of China (English)

    程东辉; 王天峰; 易亚敏

    2011-01-01

    为了开展碳纤维布加固钢筋混凝土连续梁受力性能的研究工作,对3根两跨采用碳纤维布加固的钢筋混凝土连续梁进行三分点加载的受力性能试验研究,获得加固状态下钢筋混凝土连续梁正截面承载力、裂缝分布及开展、中支座塑性铰区分布长度等试验实测值和荷载-挠度曲线及内力重分布关系曲线。试验研究表明:钢筋混凝土连续梁在加固状态下的破坏呈现中支座纵向受力钢筋先屈服,跨中纵向受力钢筋后屈服,碳纤维布被拉断的形式;试验梁加载过程中有明显的内力重分布,承载力极限状态下内力重分布幅度超过50%;由于跨中碳纤维布的存在约束了连续梁的变形,从而导致中支座控制截面附近塑性区域分布长度比普通钢筋混凝土连续梁有所减小。%In order to study the mechanical behavior of concrete continuous beams strengthened with CFRP sheets, 3 two-span continuous beams were fabricated, and strengthened with CFRP sheets at each span. The test of loading on two-point was completed, from which the bearing capacity, cracks distribution, the test value of the length of plastic hinge region, curves of load-deformation and curves of internal force redistribution were obtained. The test results showed that the failure of concrete continuous beams strengthened with CFRP sheets was characterized by longtitudinal reinforcement yielded in intermediate support sections, then the longtitudinal reinforcement yielded in the middle span sections, at last carbon fiber polymer sheets were pulled off. The internal force redistribution appeared apparently in beams during loading process and the redistribution rate was over 50% in the state of ultimate bearing capacity. As CFRP confined the deflection of beams,the length of the plastic hinge region near the sections of intermediate support was reduced as compared to ordinary continuous reinforced beams.

  2. 纯牛奶中18碳TFA及9c,11 t-CLA含量的测定研究%Study on 18-carbon trans fatty acid and 9c,11t-conjugated linoleic acid contents in milk

    Institute of Scientific and Technical Information of China (English)

    章萍萍; 赵培城

    2010-01-01

    为了精确测量出纯牛奶中18碳TFA及9c,11t-CLA的含量,本实验通过毛细管气相色谱法,并采用内标法,对纯牛奶进行了检测,结果显示,纯牛奶中18碳脂肪酸的质量百分比约为35.43% ,18碳TFA的质量百分比约为2.27%,而其中C18:1-llt的质量百分比达到1.28%,占所有18碳TFA的一半以上,约为56.36%,同时,牛奶中C18:2 -9c,11t的质量百分比只为0.11%,其含量远少于TFA.

  3. 碳纤维加固钢-混凝土组合梁承载力极限状态计算%Analysis of Ultimate Load-carrying Capacity of Strengthening Steel-concrete Composite Beam Using Carbon Fiber

    Institute of Scientific and Technical Information of China (English)

    荣学亮; 黄侨

    2011-01-01

    Carbon fiber is a kind of optimal materials for bridge maintenance and reinforcement. Design method of strengthening steel-concrete composite bridges using carbon fiber was studied. Characteristic of bridge reinforce-ment under load and phasing of stress features were considered, and calculation method of ultimate limit state was suitable for existing bridge design code . Ultimate strain of carbon fiber in ultimate limit state is firstly established based on plane-section assumption and strain-lag of carbon fiber. Then computational scheme and calculation meth-od of flexural capacity in positive moment area and negative moment area for strengthening steel-concrete composite beam using carbon fiber are established respectively, which is reference for design of bridge strengthening.%碳纤维复合材料是进行桥梁维修和加固的理想材料.对采用碳纤维复合材料加固钢-混凝土组合梁桥的设计方法进行了分析.考虑桥梁结构带载加固分阶段受力的特点,与现行桥梁设计规范中承载能力极限状态计算方法相适应.首先基于平截面假设和碳纤维应变滞后的特点,确定承载能力极限状态下碳纤维片材的极限应变值.然后分别建立了碳纤维片材加固钢-混凝土组合梁在正弯矩区和负弯矩区抗弯承载力的计算图式和计算方法,可供桥梁加固工程设计参考.

  4. Experimental study of proton beam halo in mismatched beams

    International Nuclear Information System (INIS)

    We report measurements of transverse beam-halo formation in mismatched proton beams in a 52-quadrupole FODO-transport channel following the 6.7 MeV RFQ at the Low-Energy Demonstration Accelerator (LEDA) at Los Alamos. Beam profiles in both transverse planes were measured using a new diagnostic device that consists of a movable carbon filament for measurement of the beam core, and scraper plates for measurement of the outer part of the distributions. The initial results indicate a surprisingly strong growth rate of the rms emittance even for the modest space-charge tune depressions of the experiment. Our results are consistent with the complete transfer of free energy of the mismatched beams into emittance growth within 10 envelope oscillations for both the breathing and the quadrupole modes.

  5. Beam Instabilities

    CERN Document Server

    Rumolo, G

    2014-01-01

    When a beam propagates in an accelerator, it interacts with both the external fields and the self-generated electromagnetic fields. If the latter are strong enough, the interplay between them and a perturbation in the beam distribution function can lead to an enhancement of the initial perturbation, resulting in what we call a beam instability. This unstable motion can be controlled with a feedback system, if available, or it grows, causing beam degradation and loss. Beam instabilities in particle accelerators have been studied and analysed in detail since the late 1950s. The subject owes its relevance to the fact that the onset of instabilities usually determines the performance of an accelerator. Understanding and suppressing the underlying sources and mechanisms is therefore the key to overcoming intensity limitations, thereby pushing forward the performance reach of a machine.

  6. Dissolved inorganic carbon, pH and other variables measured from laboratory experiment studies from an experimental carbonate exposure system from 2012-02-29 to 2012-05-11 (NODC Accession 0123315)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This archival package contains the carbon chemistry measurements of a laboratory experiment study to understand the effects of ocean acidification on winter...

  7. Carbon-11 labelling of eticlopride in two different positions - a selective high-affinity ligand for the study of dopamine D-2 receptors using PET

    International Nuclear Information System (INIS)

    A new highly selective high-affinity dopamine D-2 receptor antagonist, eticlopride ((-)-(S)-5-chloro-3-ethyl-N-(1-ethyl-2-pyrrolidinyl)methyl)-6-methoxysalicylamide), was labelled with 11C in two different positions ([N-ethyl-11C]eticlopride (I) and ([methyl-11C]eticlopride (II)). Product I was prepared by N-alkylation of the N-desethyl compound with [11C]ethyl iodide. II was prepared by O-alkylation of the diphenolic precursor with [11C]methyl iodide followed by separation of the two methylated products. The radiochemical yields were 15-20% (EOB) with an overall synthesis time of 45-60 min. Both compounds were isolated by semi-preparative HPLC and the radiochemical purity was in both cases > 99%. I was injected i.v. in a Cynomolgus monkey and brain radioactivity was measured by positron emission tomography (PET). The specific activity was 70 Ci/mmol at time of injection. There was a marked accumulation of radioactivity in the basal ganglia, regions known to have a high density of dopamine D-2 receptors. (author)

  8. Induced radioactivity of a GSO scintillator by secondary fragments in carbon ion therapy and its effects on in-beam OpenPET imaging.

    Science.gov (United States)

    Hirano, Yoshiyuki; Nitta, Munetaka; Nishikido, Fumihiko; Yoshida, Eiji; Inadama, Naoko; Yamaya, Taiga

    2016-07-01

    The accumulation of induced radioactivity within in-beam PET scanner scintillators is of concern for its long-term clinical usage in particle therapy. To estimate the effects on OpenPET which we are developing for in-beam PET based on GSOZ (Zi doped Gd2SiO5), we measured the induced radioactivity of GSO activated by secondary fragments in a water phantom irradiation by a (12)C beam with an energy of 290 MeV u(-1). Radioisotopes of Na, Ce, Eu, Gd, Nd, Pm and Tb including positron emitters were observed in the gamma ray spectra of the activated GSO with a high purity Ge detector and their absolute radioactivities were calculated. We used the Monte Carlo simulation platform, Geant4 in which the observed radioactivity was assigned to the scintillators of a precisely reproduced OpenPET and the single and coincidence rates immediately after one treatment and after one-year usage were estimated for the most severe conditions. Comparing the highest coincidence rate originating from the activated scintillators (background) and the expected coincidence rate from an imaging object (signal), we determined the expected signal-to-noise ratio to be more than 7 within 3 min and more than 10 within 1 min from the scan start time. We concluded the effects of scintillator activation and their accumulation on the OpenPET imaging were small and clinical long-term usage of the OpenPET was feasible.

  9. Induced radioactivity of a GSO scintillator by secondary fragments in carbon ion therapy and its effects on in-beam OpenPET imaging.

    Science.gov (United States)

    Hirano, Yoshiyuki; Nitta, Munetaka; Nishikido, Fumihiko; Yoshida, Eiji; Inadama, Naoko; Yamaya, Taiga

    2016-07-01

    The accumulation of induced radioactivity within in-beam PET scanner scintillators is of concern for its long-term clinical usage in particle therapy. To estimate the effects on OpenPET which we are developing for in-beam PET based on GSOZ (Zi doped Gd2SiO5), we measured the induced radioactivity of GSO activated by secondary fragments in a water phantom irradiation by a (12)C beam with an energy of 290 MeV u(-1). Radioisotopes of Na, Ce, Eu, Gd, Nd, Pm and Tb including positron emitters were observed in the gamma ray spectra of the activated GSO with a high purity Ge detector and their absolute radioactivities were calculated. We used the Monte Carlo simulation platform, Geant4 in which the observed radioactivity was assigned to the scintillators of a precisely reproduced OpenPET and the single and coincidence rates immediately after one treatment and after one-year usage were estimated for the most severe conditions. Comparing the highest coincidence rate originating from the activated scintillators (background) and the expected coincidence rate from an imaging object (signal), we determined the expected signal-to-noise ratio to be more than 7 within 3 min and more than 10 within 1 min from the scan start time. We concluded the effects of scintillator activation and their accumulation on the OpenPET imaging were small and clinical long-term usage of the OpenPET was feasible. PMID:27280308

  10. Induced radioactivity of a GSO scintillator by secondary fragments in carbon ion therapy and its effects on in-beam OpenPET imaging

    Science.gov (United States)

    Hirano, Yoshiyuki; Nitta, Munetaka; Nishikido, Fumihiko; Yoshida, Eiji; Inadama, Naoko; Yamaya, Taiga

    2016-07-01

    The accumulation of induced radioactivity within in-beam PET scanner scintillators is of concern for its long-term clinical usage in particle therapy. To estimate the effects on OpenPET which we are developing for in-beam PET based on GSOZ (Zi doped Gd2SiO5), we measured the induced radioactivity of GSO activated by secondary fragments in a water phantom irradiation by a 12C beam with an energy of 290 MeV u‑1. Radioisotopes of Na, Ce, Eu, Gd, Nd, Pm and Tb including positron emitters were observed in the gamma ray spectra of the activated GSO with a high purity Ge detector and their absolute radioactivities were calculated. We used the Monte Carlo simulation platform, Geant4 in which the observed radioactivity was assigned to the scintillators of a precisely reproduced OpenPET and the single and coincidence rates immediately after one treatment and after one-year usage were estimated for the most severe conditions. Comparing the highest coincidence rate originating from the activated scintillators (background) and the expected coincidence rate from an imaging object (signal), we determined the expected signal-to-noise ratio to be more than 7 within 3 min and more than 10 within 1 min from the scan start time. We concluded the effects of scintillator activation and their accumulation on the OpenPET imaging were small and clinical long-term usage of the OpenPET was feasible.

  11. 热加工对电子束焊接TC11/Ti2AlNb双合金接头组织和性能的影响%Effect of hot working on microstructure and mechanical properties of TC11/Ti2AlNb dual-alloy joint welded by electron beam welding process

    Institute of Scientific and Technical Information of China (English)

    秦春; 姚泽坤; 李誉之; 宁永权; 郭鸿镇

    2014-01-01

    The influence of hot working on the microstructures of TC11/Ti2AlNb dual-alloy joints welded by electron beam welding (EBW) process was investigated. The tensile tests were performed at room temperature for specimens before and after thermal exposure. The results show that the fusion zone of TC11/Ti2AlNb dual-alloy joint welded by EBW is mainly composed ofβ phase. After deformation and heat treatment, the grain boundaries of the as-cast alloy are broken and the fusion zone mainly consists ofβ,α2 andα phases. The fusion zone performs poor property in the tensile test. Specimens before and after thermal exposure all fail in this area under different deformation conditions. The ultimate tensile strength of specimens after heat treatment is up to 1190 MPa at room temperature. The joints by water quenching after deformation have better plasticity with an elongation up to 4.4%. After thermal exposure at 500 °C for 100 h, the tensile strength of the specimen slightly rises while the ductility changes a little. SEM observation shows that the fracture mechanism is predominantly transgranular under different deformation conditions.%研究热加工对电子束焊接TC11/Ti2AlNb双合金接头显微组织的影响,对焊接件热暴露前后的室温拉伸性能进行测试。结果表明:电子束焊接TC11/Ti2AlNb双合金熔合区主要由β相组成;经过变形和热处理后,熔合区主要由β、α2和α相组成,同时原始铸态的晶界在变形过程中破碎。在拉伸试验中,熔合区是薄弱区域;在不同的变形条件下,试样(热暴露前后)在此区域发生断裂。热处理后试样的最大室温拉伸强度达到1190 MPa;锻后水冷试样具有较好的塑性,其伸长率达到4.4%。相比较而言,经过(500°C,100 h)的热暴露后,试样的室温拉伸强度略有上升,但塑性变化较小。拉伸断口SEM观察显示,在不同变形条件下穿晶断裂为主要的断裂机制。

  12. Volumetric Properties of the Mixture Dimethyl carbonate C3H6O3 + C10H22O5 2,5,8,11,14-Pentaoxapentadecane (VMSD1112, LB4865_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume C 'Binary Liquid Systems of Nonelectrolytes III' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Dimethyl carbonate C3H6O3 + C10H22O5 2,5,8,11,14-Pentaoxapentadecane (VMSD1112, LB4865_V)' providing data by calculation of mass density in the single-phase region(s) from low-pressure dilatometric measurements of the molar excess volume at variable mole fraction and constant temperature.

  13. Volumetric Properties of the Mixture Dimethyl carbonate C3H6O3 + C10H22O5 2,5,8,11,14-Pentaoxapentadecane (VMSD1211, LB4862_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume C 'Binary Liquid Systems of Nonelectrolytes III' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Dimethyl carbonate C3H6O3 + C10H22O5 2,5,8,11,14-Pentaoxapentadecane (VMSD1211, LB4862_V)' providing data from direct low-pressure dilatometric measurement of molar excess volume at variable mole fraction and constant temperature.

  14. Beam collimator

    CERN Multimedia

    1977-01-01

    A four-block collimator installed on a control table for positioning the alignment reference marks. Designed for use with SPS secondary beams, the collimator operates under vacuum conditions. See Annual Report 1976 p. 121 and photo 7701014.

  15. A comparison study between atomic and ionic nitrogen doped carbon films prepared by ion beam assisted cathode arc deposition at various pulse frequencies

    International Nuclear Information System (INIS)

    A comparison study of microstructure and bonds composition of carbon nitride (CNx) films fabricated at atomic and ionic nitrogen source by pulse cathode arc method was presented. The relative fractions of CN/CC bonds, N-sp3C/N-sp2C and graphite-like/pyridine-like N bonding configurations in the CN films were evaluated by combining C1s and N1s X-ray photoelectron spectroscopy with the hardness and optical band gap measurement. The dependence of microstructure (quantity, size and disordering degree of Csp2 clusters) of CNx films on the nitrogen source and pulse frequency was determined by Raman spectroscopy. Films with high atomic ratio of nitrogen/carbon (0.17) and high hardness were produced at ionic nitrogen source and low pulse frequency. The results showed that ionic nitrogen source facilitated the formation of CN bonds and N-sp2C bonding configurations (mainly in graphite-like N form). Moreover presenting an optimum pulse frequency (∼10 Hz) leaded to the most nitrogen coordinated with sp3-C and the highest ratio of CN/CC bonds in the CNx films. An equilibrium action mechanism might exist between the quantity and energy of carbon and nitrogen ions/atoms, giving more nitrogen-incorporated carbon materials. These allow us to obtain the high content of N-Csp3 bonding and expected bonding structure by optimizing pulse frequency and nitrogen source.

  16. Toward automated beam optics control

    International Nuclear Information System (INIS)

    We have begun a program aiming toward automatic control of charged-particle beam optics using artificial intelligence programming techniques. In developing our prototype, we are working with LISP machines and the KEE expert system shell. Our first goal was to develop a ''mouseable'' representation of a typical beam line. This responds actively to changes entered from the mouse or keyboard, giving an updated display of the beam line itself, its optical properties, and the instrumentation and control devices as seen by the operater. We have incorporated TRANSPORT, written in Fortran but running as a callable procedure in the LISP environment, for simulation of the beam-line optics. This paper describes the experience gained in meeting our first goal and discusses plans to extend the work so that it is usable, in realtime, on an operating beam line. 11 refs

  17. 再生混凝土梁截面碳化深度分布的计算分析%Analysis on the Distribution of Carbonation Depth across the Section of Recycled Aggregate Concrete Beams

    Institute of Scientific and Technical Information of China (English)

    雷斌; 饶春华; 扶名福; 晏育松

    2015-01-01

    首先,将裂缝弥散化并将裂缝的影响耦合到再生混凝土中 CO2的扩散系数中,基于 Fick 定律建立受力状态下再生混凝土中 CO2扩散方程,根据质量守恒定律,推导出考虑应力状态影响时再生混凝土中 CO2的传质方程;然后,通过加速碳化试验,确定了传质方程中应力水平影响系数的大小;最后,采用 MATLAB 编制有限元程序求解传质方程,确定了再生混凝土梁截面的碳化深度分布。结果表明,对于顶面不传质的再生混凝土梁,截面上的碳化深度分布很不均匀,受压区角部再生混凝土碳化深度最小,而受拉区角部再生混凝土的碳化深度最大,其值为受压区一般边再生混凝土碳化深度的2.2倍,为相应的无应力状态下同配比普通混凝土梁一般边的2.4倍。%Firstly,cracks were dispersed and their influence was included in the coefficient of CO2 diffusion, and based on the Fick’s law,the equation of CO2 diffusion was established,and according to the hypothesis that the process of CO2 diffusion complied with the principle of mass transfer,the equation of mass convec-tion was finally derived in which the effect of stress was included;Then,the value of the stress influence-factor associated with the CO2 diffusion was obtained by conducting the accelerated carbonation tests;Fi-nally,Substituting the value of the stress influence-factor associated with the CO2 diffusion into the mass convection equation and using a finite element program developed by the author with MATLAB to solve this equation,the distribution of the carbonation depth across the section of recycled aggregate concrete beams in the service-state was determined.The results showed that,for the recycled aggregate concrete beam of which the top surface had no CO2 mass transfer,the distribution of carbonation depth at section was very uneven,carbonation depth in the corner of compression zone was minimal,while the

  18. Infrared imaging diagnostics for INTF ion beam

    Science.gov (United States)

    Sudhir, D.; Bandyopadhyay, M.; Pandey, R.; Joshi, J.; Yadav, A.; Rotti, C.; Bhuyan, M.; Bansal, G.; Soni, J.; Tyagi, H.; Pandya, K.; Chakraborty, A.

    2015-04-01

    In India, testing facility named INTF [1] (Indian test facility) is being built in Institute for Plasma Research to characterize ITER-Diagnostic Neutral Beam (DNB). INTF is expected to deliver 60A negative hydrogen ion beam current of energy 100keV. The beam will be operated with 5Hz modulation having 3s ON/20s OFF duty cycle. To characterize the beam parameters several diagnostics are at different stages of design and development. One of them will be a beam dump, made of carbon fiber composite (CFC) plates placed perpendicular to the beam direction at a distance lm approximately. The beam dump needs to handle ˜ 6MW of beam power with peak power density ˜ 38.5MW/m2. The diagnostic is based on thermal (infra-red - IR) imaging of the footprint of the 1280 beamlets falling on the beam dump using four IR cameras from the rear side of the dump. The beam dump will be able to measure beam uniformity, beamlet divergence. It may give information on relative variation of negative ion stripping losses for different beam pulses. The design of this CFC based beam dump needs to address several physics and engineering issues, including some specific inputs from manufacturers. The manuscript will describe an overview of the diagnostic system and its design methodology highlighting those issues and the present status of its development.

  19. Relationship between plant growth and cytological effect in root apical meristem after exposure of wheat dry seeds to carbon ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Qingfang [Radiobiology Laboratory, Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, Gansu Province 730000 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Wang, Zhuanzi; Zhou, Libin; Qu, Ying; Lu, Dong [Radiobiology Laboratory, Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, Gansu Province 730000 (China); Yu, Lixia; Du, Yan [Radiobiology Laboratory, Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, Gansu Province 730000 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Jin, Wenjie [Radiobiology Laboratory, Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, Gansu Province 730000 (China); Li, Wenjian, E-mail: wjli@impcas.ac.cn [Radiobiology Laboratory, Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, Gansu Province 730000 (China)

    2013-06-15

    In order to analyze the relationship between plant growth and cytological effects, wheat dry seeds were exposed to various doses of {sup 12}C{sup 6+} beams and the biological endpoints reflecting plant growth and root apical meristem (RAM) activities were investigated. The results showed that most of the seeds were able to germinate normally within all dose range, while the plant survival rate descended at higher doses. The seedling growth including root length and seedling height also decreased significantly at higher doses. Mitotic index (MI) in RAM had no changes at 10 and 20 Gy and decreased obviously at higher doses and the proportion of prophase cells had the same trend with MI. These data suggested that RAM cells experienced cell cycle arrest, which should be responsible for the inhibition of root growth after exposure to higher doses irradiation. Moreover, various types of chromosome aberrations (CAs) were observed in the mitotic cells. The frequencies of mitotic cells with lagging chromosomes and these with anaphase bridges peaked around 60 Gy, while the frequencies of these with fragments increased as the irradiation doses increased up to 200 Gy. The total frequencies of mitotic cells with CAs induced by irradiation increased significantly with the increasing doses. The serious damage of mitotic chromosomes maybe caused cell cycle arrest or cell death. These findings suggested that the influences of {sup 12}C{sup 6+} beams irradiation on plant growth were related to the alternation of mitotic activities and the chromosomal damages in RAM.

  20. Potential use of carbon-11 labeled alpha-aminoisobutyric acid (AIB) as an in vivo tracer of amino acid uptake in differing metabolic states

    International Nuclear Information System (INIS)

    AIB has been used as a model amino acid for the evaluation of alanine-preferring amino acid transport. Hormonal factors and starvation alter the tissue distribution of amino acids, particularly in liver and muscle. With positron emission tomography and labeling of biochemical tracers with C-11, (t1/2=20.4 min), it is now possible to study amino acid kinetics in vivo using external imaging. In order to investigate the utility of C-11 AIB as an in vivo tracer of altered tissue metabolism, C-14 AIB was studied in groups of rats with either streptozotocin-induced diabetes, insulin-induced hypoglycemia or starvation. The data suggest an increased amino acid uptake in liver in starvation, an increased uptake in muscle in response to insulin and associated hypoglycemia and decreased transport in muscle in starvation, as seen by other investigators. These results suggest that C-11 AIB may be useful as an in vivo monitor of metabolic changes in body tissues

  1. Spectroelectrochemical Study of Carbon Monoxide and Ethanol Oxidation on Pt/C, PtSn(3:1)/C and PtSn(1:1)/C Catalysts.

    Science.gov (United States)

    Rizo, Rubén; Lázaro, María Jesús; Pastor, Elena; García, Gonzalo

    2016-01-01

    PtSn-based catalysts are one of the most active materials toward that contribute ethanol oxidation reaction (EOR). In order to gain a better understanding of the Sn influence on the carbon monoxide (principal catalyst poison) and ethanol oxidation reactions in acidic media, a systematic spectroelectrochemical study was carried out. With this end, carbon-supported PtSnx (x = 0, 1/3 and 1) materials were synthesized and employed as anodic catalysts for both reactions. In situ Fourier transform infrared spectroscopy (FTIRS) and differential electrochemical mass spectrometry (DEMS) indicate that Sn diminishes the amount of bridge bonded CO (COB) and greatly improves the CO tolerance of Pt-based catalysts. Regarding the effect of Sn loading on the EOR, it enhances the catalytic activity and decreases the onset potential. FTIRS and DEMS analysis indicate that the C-C bond scission occurs at low overpotentials and at the same potential values regardless of the Sn loading, although the amount of C-C bond breaking decreases with the rise of Sn in the catalytic material. Therefore, the elevated catalytic activity toward the EOR at PtSn-based electrodes is mainly associated with the improved CO tolerance and the incomplete oxidation of ethanol to form acetic acid and acetaldehyde species, causing the formation of a higher amount of both C2 products with the rise of Sn loading. PMID:27626404

  2. Inorganic and Organic Carbon, Nutrient, and Oxygen Data from the R/V Ronald H. Brown Repeat Hydrography Cruise in the Atlantic Ocean: CLIVAR CO2 Section A16N_2003a (4 June-11 August, 2003)

    Energy Technology Data Exchange (ETDEWEB)

    Kozyr, Alex [Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States). Carbon Dioxide Information Analysis Center

    2005-08-30

    This report presents methods and analytical and quality control procedures for nutrient, oxygen, and inorganic carbon system parameters performed during the A16N_2003a cruise, which took place from June 4 to August 11, 2003 aboard NOAA Ship R/V Ronald H. Brown under auspices of the National Oceanic and Atmospheric Administration (NOAA). The first hydrographic leg (June 19–July 10) was from Reykjavik, Iceland, to Funchal, Madeira, Portugal along the 20°W meridian, and the second leg (July 15–August 11) continued operations from Funchal, Portugal to Natal, Brazil, on a track southward and ending at 6°S, 25°W. The research was the first in a decadal series of repeat hydrography sections jointly funded by NOAA and the National Science Foundation (NSF) as part of the CLIVAR/CO2/hydrography/tracer program. Samples were taken from up to 34 depths at 150 stations. The data presented in this report includes the analyses of water samples for total inorganic carbon (TCO2), fugacity of CO2 (fCO2), total alkalinity (TALK), pH, nitrate (NO3), nitrite (NO2), phosphate (PO4), silicate (SiO4), and dissolved oxygen (O2). The R/V Ronald H. Brown A16N_2003a data set is available free of charge as a numeric data package (NDP) from the Carbon Dioxide Information Analysis Center (CDIAC). The NDP consists of the oceanographic data files and this printed documentation, which describes the procedures and methods used to obtain the data.

  3. Use of the mar-lin criteria to determine the influence of porosity on the iosipescu and short beam shear properties in carbon fiber polymer matrix composites

    OpenAIRE

    Antonio Carlos Ancelotti Junior; Luiz Claudio Pardini; Eduardo Marcelo Bezerra; Dennis Roach

    2010-01-01

    To address a critical aspect of the fast growing use of composites in aircraft and aerospace industry, the influence of the porosity on the shear strength of composites property was investigated as a mean for determining the critical values of porosity. Acid digestion techniques were applied to determine the void volume ratio of two families of carbon epoxy laminates (8 and 16 plies). Ultrasonic inspections revealed the corresponding attenuation coefficients. The void morphology was investiga...

  4. From carbon nanotubes to carbon atomic chains

    Science.gov (United States)

    Casillas García, Gilberto; Zhang, Weijia; José-Yacamán, Miguel

    2010-10-01

    Carbyne is a linear allotrope of carbon. It is formed by a linear arrangement of carbon atoms with sp-hybridization. We present a reliable and reproducible experiment to obtain these carbon atomic chains using few-layer-graphene (FLG) sheets and a HRTEM. First the FLG sheets were synthesized from worm-like exfoliated graphite and then drop-casted on a lacey-carbon copper grid. Once in the TEM, two holes are opened near each other in a FLG sheet by focusing the electron beam into a small spot. Due to the radiation, the carbon atoms rearrange themselves between the two holes and form carbon fibers. The beam is concentrated on the carbon fibers in order excite the atoms and induce a tension until multi wall carbon nanotube (MWCNT) is formed. As the radiation continues the MWCNT breaks down until there is only a single wall carbon nanotube (SWCNT). Then, when the SWCNT breaks, an atomic carbon chain is formed, lasts for several seconds under the radiation and finally breaks. This demonstrates the stability of this carbon structure.

  5. A refined method for quantification of myocardial oxygen consumption rate using mean transit time with carbon-11-acetate and dynamic PET.

    Science.gov (United States)

    Choi, Y; Huang, S C; Hawkins, R A; Hoh, C K; Krivokapich, J; Buxton, D B; Armbrecht, J J; Sun, K T; Phelps, M E; Schelbert, H R

    1993-11-01

    The utility of the mean transit time equation was investigated for estimation of the myocardial clearance rate constant of 11C-acetate, which is proportional to myocardial oxygen consumption rates. The mean transit time approach was also employed to generate parametric images of the clearance rate constant of 11C-acetate with dynamic PET imaging in 20 normal human studies. Input function delays and cutoff errors due to the truncation of the myocardial tissue time-activity curve at a finite time were corrected. The clearance rate constants estimated by mean transit time correlated well with the estimates by conventional monoexponential fitting (15 min (truncation time): Y = 0.01 + 0.94X, correlated coefficient (r) = 0.99; 16 min: Y = 0.03 + 0.94X, r = 0.98; 20 min: Y = 0.03 + 0.84X, r = 0.99). The clearance rate constants estimated by the mean transit time approach also correlated well (r = 0.94) with the measured rate-pressure products. The quality and noise level of parametric images of the clearance rate constants generated by mean transit time are improved over those generated by monoexponential fitting. Additional advantages of the mean transit time approach compared to the standard monoexponential fitting method for estimating myocardial clearance rate constant of 11C-acetate include ease of input function delay correction, less sensitivity to the shape of the input function and elimination of subjective data selection of the linear portion of the clearance data on a semilog plot. Thus, this approach is expected to facilitate objective quantitative analysis of indices of myocardial oxygen consumption. PMID:8229256

  6. Non-invasive estimation of myocardial efficiency using positron emission tomography and carbon-11 acetate - comparison between the normal and failing human heart

    International Nuclear Information System (INIS)

    We studied ten patients with idiopathic dilated cardiomyopathy (DCM) and 11 healthy normals by dynamic PET with 11C-acetate and either tomographic radionuclide ventriculography or cine magnetic resonance imaging. A ''stroke work index'' (SWI) was calculated by: SWI = systolic blood pressure x stroke volume/body surface area. To estimate myocardial efficiency, a ''work-metabolic index'' (WMI) was then obtained as follows: WMI = SWI x heart rate/k(mono), where k(mono) is the washout constant for 11C-acetate derived from mono-exponential fitting. In DCM patients, left ventricular ejection fraction was 19%±10% and end-diastolic volume was 92±28 ml/m2 (vs 64%±7% and 55±8 ml/m2 in normals, P2; P6 mmHg x ml/m2; P<0.001) were lower in DCM patients, too. Overall, the WMI correlated positively with ejection parameters (r=0.73, P<0.001 for ejection fraction; r=0.93, P<0.001 for stroke volume), and inversely with systemic vascular resistance (r=-0.77; P<0.001). There was a weak positive correlation between WMI and end-diastolic volume in normals (r=0.45; P=0.17), while in DCM patients, a non-significant negative correlation coefficient (r=-0.21; P=0.57) was obtained. In conclusion non-invasive estimates of oxygen consumption and efficiency in the failing heart were reduced compared with those in normals. Estimates of efficiency increased with increasing contractile performance, and decreased with increasing ventricular afterload. In contrast to normals, the failing heart was not able to respond with an increase in efficiency to increasing ventricular volume.(orig./MG) (orig.)

  7. Beam emittance measurements in RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Zelenski,A.; Bazilevsky, A.; Bunce, G.; Gill, R.; Huang, H.; Makdisi, Y.; Morozov, B.; Nemesure, S.; Russo, t.; Steski, D.; Sivertz, M.

    2009-05-04

    The RHIC proton polarimeters can operate in scanning mode, giving polarization profiles and transverse beam intensity profile (beam emittance) measurements. The polarimeters function as wire scanners, providing a very good signal/noise ratio and high counting rate. This allows accurate bunch-by-bunch emittance measurements during fast target sweeps (<1 s) through the beam. Very thin carbon strip targets make these measurements practically non-destructive. Bunch by bunch emittance measurements are a powerful tool for machine set-up; in RHIC, individual proton beam transverse emittances can only be measured by CNI polarimeter scans. We discuss the consistency of these measurements with Ionization Profile Monitors (IPMs) and vernier scan luminosity measurements. Absolute accuracy limitations and cross-calibration of different techniques are also discussed.

  8. At WA11

    CERN Multimedia

    1977-01-01

    Starting with february 1977 the WA5 spectrometer of the Indiana-Saclay Collaboration originally designed to study hadron backward scattering on protons, and later modified by the Indiana-Imperial College (London)-Saclay-Southampton Collaboration, was used (experiment WA11) to search for high mass states produced with the J/psi. On the left, Tom Marshall moves in a beam hodoscope. On the right, at the entrance of the Goliath magnet, one sees the 1 m long hydrogen target. (Later the set-up was reshuffled, and the hydrogen target was replaced by a set of Be targets located upstream of the magnet.)

  9. Breeding pleuromutilin protoplasts strains by carbon ion beam irradiation%碳离子束辐照选育截短侧耳素菌原生质体

    Institute of Scientific and Technical Information of China (English)

    都雯玥; 陆锡宏; 李雪虎; 周翔; 梁剑平; 辛志君

    2016-01-01

    使用12C6+离子束辐照Clitopilus pinsitus原生质体至不同吸收剂量,运用琼脂柱预筛和96孔板固体发酵选育截短侧耳素高产变异株.结果显示,最佳12C6+离子束吸收剂量为1.5 Gy,在该吸收剂量下正变异率为37.58%.选育出C.pin15Ⅰ5E和C.pin15Ⅱ6B两株正变异株,其产量较出发菌株分别提高16.17%和15.47%.表明重离子束辐照原生质体是行之有效的工业微生物诱变育种方法.%Clitopilus pinsitusprotoplast was irradiated by12C6+ion beam at varied absorbed doses for mutagenesis, and high-yielding pleuromutilin mutant strains were screened using high-throughput method and solid fermentation. The results showed that the optimum12C6+ ion beam absorbed dose is 1.5 Gy, and under this condition the positive mutation rate is 37.58%. By agar column prescreening and 96-plate solid fermentation, the mutant strains, C.pin15Ⅰ5E and C.pin15Ⅱ6B, were selected. The yields of the strain increased by 16.17% and 15.47%, respectively, compared with that of the original strain. The research suggests that applying heavy ion irradiation to protoplast is a possible method to breed mutant strains.

  10. Turn-By Beam Extraction during Acceleration in a Synchrotron

    Science.gov (United States)

    Tsoupas, Nicholaos; Trbojevic, Dejan

    2014-02-01

    A synchrotron to accelerate protons or carbon ions for medical applications is being designed at Brookhaven National Laboratory (BNL). Single beam bunches with maximum beam energy of 1.18 GeV and 400 MeV/u for protons and carbon ions respectively will be extracted from the synchrotron at 15 Hz. For protons, the maximum required energy for irradiating a tumor is ˜206 MeV. A pencil-like proton beam containing ˜5.4×107 p/bunch delivers a therapeutic dose of 2.5 Gy in ˜1.5 minutes to treat a tumor of 1 liter volume. It will take ˜80 minutes with bunches containing 4.5×104 ions/bunch to deliver the same dose of 2.5 Gy with a 400 MeV/u pencil-like carbon beam. This extended treatment time when using carbon ions is not acceptable. In addition, the synchrotron cannot be controlled with a beam bunch containing such a low number of carbon ions. To overcome these two problems of the extended treatment time and the low bunch intensity required for the treatment when carbon ions are used, we have devised a method to “peel” the required 4.5×104 carbon-ions/bunch from the accelerating carbon beam bunch containing ˜108 ions/bunch and deliver them to the tumor on a “turn-by-turn” basis. Unlike other methods of beam extraction from a synchrotron, such as resonance extraction, this method does not allow for any beam losses during the extraction and the carbon beam can be peeled off in less than 15 ms during the acceleration or deceleration cycle of the synchrotron. Thus, this turn-by-turn beam extraction method provides beam with variable energy and precisely controlled beam current during the 30 ms acceleration or deceleration time.

  11. Radioactive ion beam development in Berkeley

    CERN Document Server

    Wutte, D C; Leitner, M A; Xie, Z Q

    1999-01-01

    Two radioactive ion beam projects are under development at the 88" Cyclotron, BEARS (Berkeley Experiment with accelerated radioactive species) and the 14O experiment. The projects are initially focused on the production of 11C and 14O, but it is planned to expand the program to 17F, 18F, 13N and 76Kr. For the BEARS project, the radioactivity is produced in form of either CO2 or N2O in a small medical 10 MeV proton cyclotron. The activity is then transported through a 300 m long He-jet line to the 88" cyclotron building, injected into the AECR-U ion source and accelerated through the 88" cyclotron to energies between 1 to 30 MeV/ nucleon. The 14O experiment is a new experiment at the 88" cyclotron to measure the energy-shape of the beta decay spectrum. For this purpose, a target transfer line and a radioactive ion beam test stand has been constructed. The radioactivity is produced in form of CO in a hot carbon target with a 20 MeV 3He from the 88" Cyclotron. The activity diffuses through an 8m long stainless s...

  12. Particle Beam Therapy for Cancer of the Skull Base, Nasal Cavity, and Paranasal Sinus

    OpenAIRE

    Fukumitsu, Nobuyoshi

    2012-01-01

    Particle beam therapy has been rapidly developed in these several decades. Proton and carbon ion beams are most frequently used in particle beam therapy. Proton and carbon ion beam radiotherapy have physical and biological advantage to the conventional photon radiotherapy. Cancers of the skull base, nasal cavity, and paranasal sinus are rare; however these diseases can receive the benefits of particle beam radiotherapy. This paper describes the clinical review of the cancer of the skull base,...

  13. Evaluation of surface energy and carbon fluxes within a large wind farm during the CWEX-10/11 Crop Wind-energy EXperiments

    Science.gov (United States)

    Rajewski, D. A.; Takle, E. S.; Prueger, J. H.; Oncley, S.; Horst, T. W.; Pfeiffer, R.; Hatfield, J.; Spoth, K. K.; Doorenbos, R.

    2012-12-01

    The Crop Wind-energy EXperiment conducted in summer 2010 (very moist conditions) and summer 2011 (abnormally dry) included measurements of wind speed, temperature, relative humidity, turbulence kinetic energy, H2O, and CO2 at stations north and south of a line of turbines at the southwest edge of a large-scale 200-turbine wind farm (prevailing wind from the south). In contrast to previous studies that have reported turbine influences on surface wind speed and temperature, this report focuses on scalar fluxes of heat, H2O, and CO2. From previous measurements in agricultural fields we recognize the importance of non-turbine factors in analysis of the flux differences: variability of soil characteristics, moisture content, crop cultivar, management practices, planting dates, etc., which can create differences in what looks like a uniform field of maize (corn). We conceptualize the influences of turbines at canopy height at a given location in the field to arise from (1) wakes of reduced wind speed and turbulence conditions different from ambient that intersect the surface, (2) wakes that are passing overhead and interrupt the ambient turbulence that scales with height, or (3) changes in static pressure upwind and downwind of lines of turbines that create small-scale pressure gradients, localized flows, and changes to the vertical exchange of scalar variables. The turbine SCADA wind speed and wind direction provided by the wind farm operator facilitated our comparison of surface fluxes upwind and downwind as wakes moved laterally throughout the day and night. We report multiple levels of evidence that wind turbines increase vertical exchange of carbon dioxide and water vapor over the canopy. Latent heat and carbon fluxes are responsive to slight changes in the turbine wake position, and the flux differences are maximized when the periphery of the wake edge is above the station. The flux stations north of the turbine line report a larger net ecosystem exchange

  14. Dissolved inorganic carbon, alkalinity, temperature, salinity and other variables collected from discrete sample and profile observations using CTD, bottle and other instruments from the THOMAS G. THOMPSON in the North Pacific Ocean from 1997-11-01 to 1997-11-11 (NODC Accession 0115176)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NODC Accession 0115176 includes chemical, discrete sample, physical and profile data collected from THOMAS G. THOMPSON in the North Pacific Ocean from 1997-11-01 to...

  15. Measurement of the electroweak charge asymmetry of the cross section of the deep inelastic scattering of muons on carbon at 200 GeV beam momentum

    International Nuclear Information System (INIS)

    In the experiment described here the weak neutral current was detected for the first time in the inclusive deep inelastic muon-nucleon scattering μsup(+-)+N->μsup(+-)+X. In this reaction the γ-Z0 interference effects an asymmetry of the cross section at simultaneous change of charge and polarization of the muon beam. In the model of Glashow, Salam, and Weinberg this asymmetry is calculable and is in the kinematical range of this measurement in the order of magnitude of 1%. The results are in full agreement with the prediction and confirm for the first time the electron-muon universality of the coupling to the weak neutral current. According to the scales of high energy physics the measurement of a so small effect represents a precision experiment. A careful control of the systematic errors lies therefore in the center of the study. Beyond this thesis contains contributions which are also of importance for the analysis of other measurements with the same apparatus. (orig./HSI)

  16. Additional heat treatment of non-porous coatings obtained on medium carbon steel substrates by electron beam cladding of a Ti-Mo-C powder composition

    Science.gov (United States)

    Mul, D. O.; Drobyaz, E. A.; Zimoglyadova, T. A.; Bataev, V. A.; Lazurenko, D. V.; Shevtsova, L. I.

    2016-04-01

    The structure and microhardness of surface layers, obtained by non-vacuum electron beam cladding of Ti-Mo-C powder mixture on a steel substrate after different types of heat treatment, were investigated. After cladding samples were heat treated in a furnace at 200...500 °C, as well as quenched at 860 ° C and then underwent high-temperature tempering. Heat treatment of cladded coatings induced tempering of martensite and precipitation of cementite particles (Fe3C). Transmission electron microscopy of the samples after heating and holding at 300 ° C revealed precipitation of nanosized cubical TiC particles. The formation of hard nanosized particles led to the surface layer microhardness growth. The highest level of microhardness (which was 1.2...1.5-fold higher in comparison with coating microhardness after heat treatment) was achieved after heating of the claded material at 300 °C and 400 °C Additional quenching of samples at 860 °C did not increase the microhardness level.

  17. Investigation of innovative steel runway beam in industrial building

    Indian Academy of Sciences (India)

    Mahyar Maali; Abdulkadir Cüneyt Aydin; Merve Sağiroğlu

    2015-10-01

    The design of a runway beam for overhead cranes is of great importance when constructing steel structures, as is the lateral-torsional buckling (LTB) value obtained for I-beam sections. Therefore, engineers must always consider the optimal design of these beams under overhead cranes loads. In this study, runway beams of three overhead crane groups were analyzed for LTB, and a sinusoidal runway beam body was developed. These runway beams with different sinusoidal angles were analyzed by using the finite element method (ABAQUS) and compared to each other and other runway IPE-IPN beam sections; furthermore, all models were compared with the Canadian Institute of Steel Construction standard. As a result, a new method was proposed for developing sinusoidal runway beams for overhead cranes. The sinusoidal runway beam has lower weight than runway IPE-IPN beam sections. Ultimately, a sinusoidal beam body was developed practically with a scale of 1:1.

  18. In vivo visualization of alpha-synuclein deposition by carbon-11-labelled 2-[2-(2-dimethylaminothiazol-5-yl)ethenyl]-6-[2-(fluoro)ethoxy]benzoxazole positron emission tomography in multiple system atrophy.

    Science.gov (United States)

    Kikuchi, Akio; Takeda, Atsushi; Okamura, Nobuyuki; Tashiro, Manabu; Hasegawa, Takafumi; Furumoto, Shozo; Kobayashi, Michiko; Sugeno, Naoto; Baba, Toru; Miki, Yasuo; Mori, Fumiaki; Wakabayashi, Koichi; Funaki, Yoshihito; Iwata, Ren; Takahashi, Shoki; Fukuda, Hiroshi; Arai, Hiroyuki; Kudo, Yukitsuka; Yanai, Kazuhiko; Itoyama, Yasuto

    2010-06-01

    The histopathological hallmark of multiple system atrophy is the appearance of intracellular inclusion bodies, named glial cytoplasmic inclusions, which are mainly composed of alpha-synuclein fibrils. In vivo visualization of alpha-synuclein deposition should be used for the diagnosis and assessment of therapy and severity of pathological progression in multiple system atrophy. Because 2-[2-(2-dimethylaminothiazol-5-yl)ethenyl]-6-[2-(fluoro)ethoxy] benzoxazole could stain alpha-synuclein-containing glial cytoplasmic inclusions in post-mortem brains, we compared the carbon-11-labelled 2-[2-(2-dimethylaminothiazol-5-yl)ethenyl]-6-[2-(fluoro)ethoxy] benzoxazole positron emission tomography findings of eight multiple system atrophy cases to those of age-matched normal controls. The positron emission tomography data demonstrated high distribution volumes in the subcortical white matter (uncorrected P benzoxazole positron emission tomography is a promising surrogate marker for monitoring intracellular alpha-synuclein deposition in living brains.

  19. Successive ionization of positive ions of carbon and nitrogen by electron bombardment

    International Nuclear Information System (INIS)

    Experimental studies of deep ionization of heavy ions are described. The applications of such studies in atomic physics, plasma physics and space physics are discussed. Investigations using intersecting ion-electron beams, shifted beams and ion trap sources are described, and data are presented for multi-charged ions of carbon, oxygen and nitrogen. A detailed description of the development of the IEL (electron beam ionizer) source, and the KRION (cryogenic version) source is given, and further data for the multiple ionization of carbon and nitrogen are given for charge states up to C6+ and N7+. The advantages and disadvantages of the KRION source are discussed, and preliminary studies of a new torroidal ion trap source (HIRAC) are presented. (11 figs, 57 refs) (U.S.)

  20. High pressure study of low compressibility tetracalcium aluminum carbonate hydrates 3CaO·Al2O3·CaCO3·11H2O

    KAUST Repository

    Moon, Juhyuk

    2012-01-01

    Synchrotron X-ray diffraction data was collected from a sample of monocarboaluminate 3CaO•Al2O3•CaCO 3•11H2O from ambient pressure to 4.3 GPa. The refined crystal structure at ambient pressure is triclinic with parameters a = 5.77(2) Å, b = 8.47(5) Å, c = 9.93(4) Å, α = 64.6(2)°, β = 82.8(3)°, γ = 81.4(4)°, and space group of P1 or P1̄. It showed some degree of perfectly reversible pressure-induced dehydration with a non-hygroscopic pressure-transmitting medium. However the dehydration effect does not critically affect a bulk modulus due to its strong framework. The isothermal bulk modulus of monocarboaluminate was found to be 53(5) GPa and 54(4) GPa with 3rd order and 2nd order Birch-Murnaghan Equation of state, respectively. That value is higher than for any other reported AFm or AFt phase. The pressure-volume behavior of the monocarboaluminate was compared with that of previous studied hemicarboaluminate. © 2011 Elsevier Ltd. All rights reserved.

  1. 预应力碳纤维片材在结构加固中的应用研究——以其对钢筋混凝土梁力学性能的增强为例%A Study on the Application of Prestressed Carbon Fiber Sheet Structure Reinforcement: Take the Reinforcement of Mechanical Performance of Reinforced Concrete Beams by it for Example

    Institute of Scientific and Technical Information of China (English)

    何令

    2012-01-01

    文章通过大型商业有限元软件ANSYS/Civil对预应力碳纤维片材增强钢筋混凝土梁的抗弯性能进行了数值模拟,分析了普通RC梁、碳纤维布增强RC梁、预应力碳纤维布增强RC梁的抗弯承载力、受力钢筋应力历程、RC梁挠度历程等力学性能.结果表明,粘贴预应力碳纤维布能够更好的改善钢筋混凝土梁的受力,提高增强RC梁的承载能力.%This article presents the carrying-out of the numerical simulation of the enhanced flexural performance of the concrete beams prestressed carbon fiber sheet of large commercial finite dement software ANSYS/Civil. It analyzes the mechanics properties of ordinary RC beam, carbon fiber enhanced RE beam, the bending proof carrying capacity of prestressed carbon fiber enhanced RC beam, the stress course of reinforced steel, the deflection proof course of RC beam. The finding reveals that bonding prestressed carbon fiber sheet is more capable to relax the stress on the steel concrete and enhance the stress of RC beams.

  2. Multi-beam linear accelerator EVT

    Science.gov (United States)

    Teryaev, Vladimir E.; Kazakov, Sergey Yu.; Hirshfield, Jay L.

    2016-09-01

    A novel electron multi-beam accelerator is presented. The accelerator, short-named EVT (Electron Voltage Transformer) belongs to the class of two-beam accelerators. It combines an RF generator and essentially an accelerator within the same vacuum envelope. Drive beam-lets and an accelerated beam are modulated in RF modulators and then bunches pass into an accelerating structure, comprising uncoupled with each other and inductive tuned cavities, where the energy transfer from the drive beams to the accelerated beam occurs. A phasing of bunches is solved by choice correspond distances between gaps of the adjacent cavities. Preliminary results of numerical simulations and the initial specification of EVT operating in S-band, with a 60 kV gun and generating a 2.7 A, 1.1 MV beam at its output is presented. A relatively high efficiency of 67% and high design average power suggest that EVT can find its use in industrial applications.

  3. Carbon dioxide, hydrographic, and chemical data obtained during the R/V Meteor Cruise 11/5 in the South Atlantic and Northern Weddell Sea areas (WOCE sections A-12 and A-21)

    Energy Technology Data Exchange (ETDEWEB)

    Chipman, D.W.; Takahashi, T.; Breger, D.; Sutherland, S.C. [Columbia Univ., Palisades, NY (United States). Lamont-Doherty Earth Observatory; Kozyr, A. [Oak Ridge National Lab., TN (United States). Carbon Dioxide Information Analysis Center]|[Tennessee Univ., Knoxville, TN (United States). Energy, Environment and Resources Center; Gaslightwala, A.F. [Oak Ridge National Lab., TN (United States). Carbon Dioxide Information Analysis Center]|[Cornell Univ., Ithaca, NY (United States)

    1994-07-01

    This document presents the procedures and methods used to obtain carbon dioxide (CO{sub 2}), hydrographic, and chemical data during R/V Meteor Expedition 11/5 in the South Atlantic Ocean, including the Drake Passage; the Northern Weddell Sea; and the Eastern South Atlantic Ocean. This cruise was conducted as part of the World Ocean Circulation Experiment (WOCE). The cruise started from Ushuaia, Argentina, on January 23, 1990, and ended at Capetown, South Africa on March 8, 1990. Samples were collected at 78 stations that covered the Drake Passage; the Northern Weddell Sea; a section along the 58 W parallel; and two segmented S-N sections between the Northern Weddell Sea and Capetown, South Africa. Measurements taken at WOCE sections A-12 and A-21 included pressure, temperature, salinity measured by the Conductivity, Temperature and Depth sensor (CTD); bottle salinity; oxygen; phosphate; nitrate; nitrate; silicate; total carbon concentration (TCO{sub 2}); and partial pressure of CO{sub 2} (pCO{sub 2}) measured at 20 C. In addition, potential density at 0 decibar (dbar) and potential temperature were calculated from the measured variables. The TCO{sub 2} concentration in seawater samples was measured using a coulometer with an estimated precision of approximately {+-} {mu}mol/kg.

  4. External Beam Therapy (EBT)

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z External Beam Therapy (EBT) External beam therapy (EBT) is a ... follow-up should I expect? What is external beam therapy and how is it used? External beam ...

  5. Obtention of thermoluminescent efficiencies by means of irradiation of TLD-100 dosemeters with proton beams helium and carbon; Obtencion de eficiencias termoluminiscentes mediante irradiacion de dosimetros TLD-100 con haces de protones, helios y carbon

    Energy Technology Data Exchange (ETDEWEB)

    Avila, O.; Rodriguez V, M.; Aviles, P.; Gamboa de Buen, I.; Buenfil, A.E.; Ruiz T, C.; Brandan, M.E. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2002-07-01

    In this work, the advances of a serial of measurements of relative efficiency thermoluminescent of heavy charged particles (PCP) with respect to gamma radiation for TLD-100, dosemeters of LiF: Mg,Ti manufactured by the Harshaw-Bicron company are reported. The PCP are essentials in the implementation of dosimetry associated with medical applications. The measurements before gamma radiation were carrying out using the Vickrad irradiator of the National Institute of Nuclear Research at dose of 1.663 Gy. The measures which are reported about protons, helium and carbon were realized using the Pelletron accelerator of the Physics Institute of the UNAM. (Author)

  6. j399sf.m77t and j399sf.h77t: MGD77T data and header files for single-beam bathymetry data for field activity J-3-99-SF in Grizzly Bay, San Francisco Bay from 11/08/1999 to 11/18/1999

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — Single-beam bathymetry data along with DGPS navigation data was collected as part of the U.S. Geological Survey cruise J-3-99-SF. The cruise was conducted in...

  7. Induction of apoptosis in murione spleen lymphocytes using carbon ion beam; Induction de l'apoptose dans les lymphocytes spleniques de souris par un faisceau d'ions carbone

    Energy Technology Data Exchange (ETDEWEB)

    Holl, V.; Coelho, D. [Lab. de Cancerologie Experimentale et de Radiobiologie, LCER, Inst. de Recherche contre les Cancers de l' Appareil Digestif, Hopitaux Universitaires, Strasbourg (France); Weltin, D. [Faculte de Medecine, Strasbourg (France); Dufour, P. [Lab. de Cancerologie Experimentale et de Radiobiologie, LCER, Inst. de Recherche contre les Cancers de l' Appareil Digestif, Hopitaux Universitaires, Strasbourg (France); Denis, J.M. [Faculte de Medecine, Univ. Catholique de Louvain, Bruxelles (Belgium); Florentin, I. [Centre National de la Recherche Scientifique, CNRS, Unite de Recherche Associee, Hopital Cochin, Paris (France); Mathieu, J. [Centre de Recherche du Service de Sante des Armees, CRSSA, La Tronche (France); Gueulette, J. [Faculte de Medecine, Univ. Catholique de Louvain, Bruxelles (Belgium); Bischoff, P. [Lab. de Cancerologie Experimentale et de Radiobiologie, LCER, Inst. de Recherche contre les Cancers de l' Appareil Digestif, Hopitaux Universitaires, Strasbourg (France)

    2001-02-01

    To assess the capacity of heavy ions to induce apoptosis in lymphocytes, mice have been irradiated with accelerated carbon ions (95 MeV/nucleon) at doses ranging from 0.1 to 4 Gy. Their spleens were removed 24 h later and gently dissociated to prepare a single cell suspension. Mononuclear cells were then maintained in culture at 37{sup o}C, and the occurrence of apoptosis in these cells was analysed 24 h later. Lymphocytes were also irradiated in vitro, in the presence of Ac-DEVD-CHO, a potent caspase-3 and -7 inhibitor. Results from three experiments performed at the Grand Accelerateur National d'Ions Lourds (GANIL, Caen, France) are reported here. They indicate that carbon ions induce a marked, dose-dependent, reduction of the spleen weight and cellularity. However, in sharp contrast with spleen cells prepared from X-ray irradiated mice, only a slight increase of apoptosis is evidenced in cultured lymphocytes from mice irradiated with heavy ions. The significance of such results is discussed. So far, few data exist concerning the biological effects of heavy ions, in particular their capacity to induce apoptosis in lymphocytes; the present study provides useful clues for further investigations. (author)

  8. Use of the mar-lin criteria to determine the influence of porosity on the iosipescu and short beam shear properties in carbon fiber polymer matrix composites

    Directory of Open Access Journals (Sweden)

    Antonio Carlos Ancelotti Junior

    2010-03-01

    Full Text Available To address a critical aspect of the fast growing use of composites in aircraft and aerospace industry, the influence of the porosity on the shear strength of composites property was investigated as a mean for determining the critical values of porosity. Acid digestion techniques were applied to determine the void volume ratio of two families of carbon epoxy laminates (8 and 16 plies. Ultrasonic inspections revealed the corresponding attenuation coefficients. The void morphology was investigated by optical microscopy. Results from Interlaminar shear and Iosipescu shear tests were correlated with the attenuation coefficient to determine critical values of porosity using a modified Mar-Lin fracture criteria. It has been shown that the shear strength decrease with the increase of void volume ratio and the effects are more significant in thicker laminates. This work showed that by using the Mar-Lin criteria the singularity order, which is an indicative of the sensibility to voids in composites, is dependent of type of loading and void distribution.

  9. GF11

    Science.gov (United States)

    Beetem, J.; Denneau, M.; Weingarten, D.

    1986-06-01

    GF11 is a parallel processor currently under construction at the IBM Yorktown Research Center. The machine incorporates 576 floating-point boards. Each board has space for 2 × 106 bytes of memory and is capable of 2 × 107 floating point operations per second, given the total machine a peak of 1.15 × 109 bytes of memory and 1.15× 1010 floating point operations per second. The floating-point processors are interconnected by a dynamically reconfigurable switching network. At each machine cycle any of 1024 preselected permutations of data can be realized among the processors. The main intended application of GF11 is a class of calculations arising from quantum chormodynamics.

  10. Multiply charged ion beams from solid substances

    International Nuclear Information System (INIS)

    The mVINIS Ion Source has enabled us to obtain multiply charged ion beams from gases as well as from solid materials. The solid substance ion beams were produced by using two techniques: a) the evaporation of metals by using the inlet system based on mini-oven and b) the metal-ions-from volatile-compounds method (MIVOC) by using the modified gas inlet system. In the production of high current stable ion beams of solids with relatively high melting points (over 1000 deg) were made great efforts. The B3+ ion beam current of over 300 μA is one of the most intensive beams extracted until now. The obtained multiply charged ion beam spectra of solid substances (B, Fe and Zn) are presented as well as some of the corresponding experimental results achieved during the modification of polymers, carbon materials and fullerenes. (author)

  11. Beam quality measure for vector beams.

    Science.gov (United States)

    Ndagano, Bienvenu; Sroor, Hend; McLaren, Melanie; Rosales-Guzmán, Carmelo; Forbes, Andrew

    2016-08-01

    Vector beams have found a myriad of applications, from laser materials processing to microscopy, and are now easily produced in the laboratory. They are usually differentiated from scalar beams by qualitative measures, for example, visual inspection of beam profiles after a rotating polarizer. Here we introduce a quantitative beam quality measure for vector beams and demonstrate it on cylindrical vector vortex beams. We show how a single measure can be defined for the vector quality, from 0 (purely scalar) to 1 (purely vector). Our measure is derived from a quantum toolkit, which we show applies to classical vector beams. PMID:27472580

  12. 29 CFR 1917.11 - Housekeeping.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Housekeeping. 1917.11 Section 1917.11 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED... terminal working areas shall be stowed in stable piles with beams secured against tipping or...

  13. Transmission of the Neutral Beam Heating Beams at TJ-II

    International Nuclear Information System (INIS)

    Neutral beam injection heating has been development for the TJ-II stellarator. The beam has a port-through power between 700-1500 kW and injection energy 40 keV. The sensibility of the injection system to the changes of several parameters is analysed. Beam transmission is limited by losses processes since beam is born into the ions source until is coming into the fusion machine. For the beam transmission optimization several beam diagnostics have been developed. A carbon fiber composite (CFC) target calorimeter has been installed at TJ-II to study in situ the power density distribution of the neutral beams. The thermographic print of the beam can be recorded and analysed in a reliable way due to the highly anisotropic thermal conductivity of the target material. With the combined thermographic and calorimetric measurements it has been possible to determine the power density distribution of the beam. It has been found that a large beam halo is present, which can be explained by the extreme misalignment of the grids. This kind of halo has a deleterious effect on beam transport and must be minimized in order to improve the plasma heating capability of the beams. (Author) 155 refs

  14. The potential value of the neutral comet assay and γH2AX foci assay in assessing the radiosensitivity of carbon beam in human tumor cell lines

    International Nuclear Information System (INIS)

    Carbon ions (12C6+) are high linear energy transfer (LET) radiation characterized by higher relative biological effectiveness than low LET radiation. The assessment of tumour radiosensitivity would be particularly useful in optimizing the radiation dose during radiotherapy. The aim of the current study was to evaluate the potential value of the neutral comet assay and γH2AX foci assay in assessing 12C6+ radiosensitivity of tumour cells. The doses of 12C6+ and X-rays used in the present study were 2 and 4 Gy. The survival fraction, DNA double-strand breaks (DSB) and repair kinetics of DSB were assayed with clonogenic survival, neutral comet assay and γH2AX foci assay in human cervical carcinoma HeLa cells, hepatoma HepG2 cells, and mucoepidermoid carcinoma MEC-1 cells at the time points of 0.5, 4, 16 and 24 h after 12C6+ and X-rays irradiation. The survival fraction for 12C6+ irradiation was much more inhibited than for X-rays (p < 0.05) in all three tumour cell lines tested. Substantial amounts of residual damage, assessed by the neutral comet assay, were present after irradiation (p < 0.05). The highest residual damage was observed at 0.5 or 4 h, both for 12C6+ and X-ray irradiation. However, the residual damage in HeLa and MEC-1 cells was higher for 12C6+ than X-rays (p < 0.05). The strongest induction of γH2AX foci was observed after 30 min, for all three tumour cell lines (p < 0.01). The franction of γH2AX foci persisted for at least 24 h after 12C6+ irradiation; in HeLa cells and MEC-1 was higher than after X-ray irradiation (p < 0.05). The correlation coefficients between the clonogenic survival, neutral comet assay and γH2AX foci assay were not statistically significant, except for some tumour cells at individual irradiation doses and types. Our study demonstrated that the neutral comet assay and γ-H2AX foci assay could be used to assess the radiosensitivity of 12C6+ in human tumour cells

  15. Suite of experiments in beam H3

    CERN Multimedia

    1977-01-01

    The H3 beam runs from bottom to top, in the middle of the photo. On its left preparation is going on for WA10 in beam H5, on its right, behind the concrete wall, the S3 beam runs to BEBC. The H3 beam first meets the IKAR target of the experiment WA9 (right, bottom corner) then crosses the polarized hydrogen target of experiment WA6 sitting inside the large green magnet (centre, also visible the yellow support of the recoil chamber telescope). Finally the beam reaches WA11 and the Goliath magnet (under the white passerelle). The WA9 (left) and the WA5/11 (right) huts stand on top of the photo, the WA6 stands at the right, centre. The three experiments were running in alternance.

  16. Stable beams

    CERN Multimedia

    2015-01-01

    Stable beams: two simple words that carry so much meaning at CERN. When LHC page one switched from "squeeze" to "stable beams" at 10.40 a.m. on Wednesday, 3 June, it triggered scenes of jubilation in control rooms around the CERN sites, as the LHC experiments started to record physics data for the first time in 27 months. This is what CERN is here for, and it’s great to be back in business after such a long period of preparation for the next stage in the LHC adventure.   I’ve said it before, but I’ll say it again. This was a great achievement, and testimony to the hard and dedicated work of so many people in the global CERN community. I could start to list the teams that have contributed, but that would be a mistake. Instead, I’d simply like to say that an achievement as impressive as running the LHC – a machine of superlatives in every respect – takes the combined effort and enthusiasm of everyone ...

  17. Beam propagation

    International Nuclear Information System (INIS)

    The main part of this thesis consists of 15 published papers, in which the numerical Beam Propagating Method (BPM) is investigated, verified and used in a number of applications. In the introduction a derivation of the nonlinear Schroedinger equation is presented to connect the beginning of the soliton papers with Maxwell's equations including a nonlinear polarization. This thesis focuses on the wide use of the BPM for numerical simulations of propagating light and particle beams through different types of structures such as waveguides, fibers, tapers, Y-junctions, laser arrays and crystalline solids. We verify the BPM in the above listed problems against other numerical methods for example the Finite-element Method, perturbation methods and Runge-Kutta integration. Further, the BPM is shown to be a simple and effective way to numerically set up the Green's function in matrix form for periodic structures. The Green's function matrix can then be diagonalized with matrix methods yielding the eigensolutions of the structure. The BPM inherent transverse periodicity can be untied, if desired, by for example including an absorptive refractive index at the computational window edges. The interaction of two first-order soliton pulses is strongly dependent on the phase relationship between the individual solitons. When optical phase shift keying is used in coherent one-carrier wavelength communication, the fiber attenuation will suppress or delay the nonlinear instability. (orig.)

  18. Hydrogen adsorption in carbon nanostructures compared

    NARCIS (Netherlands)

    Schimmel, H.G.; Nijkamp, M.G.; Kearley, G.J.; Rivera, A.; de Jong, K.P.; Mulder, F.M.

    2004-01-01

    Recent reports continue to suggest high hydrogen storage capacities for some carbon nanostructures due to a stronger interaction between hydrogen and carbon. Here the interaction of hydrogen with activated charcoal, carbon nanofibers, single walled carbon nanotubes (SWNT), and electron beam ‘opened’

  19. 12C6+ ion beam induced DNA damage in human hepatocyte L02 cells detected by comet assay

    International Nuclear Information System (INIS)

    Human hepatocyte L02 cells were irradiated by the carbon ion beam with LET of 30 keV/μm and DNA strand breaks were detected immediately after the irradiation using comet assay. Based on the comet images, all the indexes of comet assay including head DNA%, tail DNA%, comet length, tail length, tail moment and olive tail moment were analyzed with CASP and SPSS 11.5 code. Statistically significant dose-effect relationships could be observed in all the indexes of comet assay and TM increased with increasing the radiation dose. These experimental results suggest that carbon ion beam with intermediate LET value would cause remarkable DNA strand breaks immediately and the damage increases in a dose-dependent manner. This work provides basic data and evidence for the risk assessment of heavy ion radiation to healthy tissue. (authors)

  20. Morphological and biochemical responses of Oryza sativa L. (cultivar MR219) to ion beam irradiation

    Institute of Scientific and Technical Information of China (English)

    Anna Pick Kiong LING; Ying Chian UNG; Sobri HUSSEIN; Abdul Rahim HARUN; Atsushi TANAKA; Hase YOSHIHIRO

    2013-01-01

    Objective:Heavy ion beam, which has emerged as a new mutagen in the mutation breeding of crops and ornamental plants, is expected to result in the induction of novel mutations. This study investigates the morphological and biochemical responses of Oryza sativa toward different doses of carbon ion beam irradiation. Methods: In this study, the dry seeds of O. sativa were irradiated at 0, 20, 40, 60, 80, 100, and 120 Gy, fol owed by in-vitro germination under control ed conditions. Morphological and biochemical studies were conducted to investigate the morphological and physiological responses of O. sativa towards ion beam irradiation. Results: The study demonstrated that low doses (10 Gy) of ion beam have a stimulating effect on the height, root length, and fresh weight of the plantlets but not on the number of leaves. Meanwhile, doses higher than 10 Gy caused reductions in all the morphological parameters studied as compared to the control samples. The highest total soluble protein content [(2.11±0.47) mg/g FW] was observed in plantlets irradiated at 20 Gy. All irradiated plantlets were found to have 0.85%to 58.32%higher specific activity of peroxidase as compared to the control samples. The present study also revealed that low doses of ion beam (10 and 20 Gy) had negligible effect on the total chlorophyl content of O. sativa plantlets while 40 Gy had a stimulating effect on the chlorophyll content. Plantlets irradiated between 40 to 120 Gy were shown to be 0.38%to 9.98%higher in total soluble nitrogen content which, however, was not significantly different from the control samples. Conclusions:Carbon ion beam irradiation administered at low to moderate doses of 10 to 40 Gy may induce O. sativa mutants with superior characteristics.

  1. Energy compensation of slow extracted beams with RF acceleration

    Science.gov (United States)

    Fujimoto, Tetsuya; Souda, Hikaru; Torikoshi, Masami; Kanai, Tatsuaki; Yamada, Satoru; Noda, Koji

    2016-03-01

    In a conventional carbon-ion radiotherapy facility, a carbon-ion beam is typically accelerated up to an optimum energy, slowly extracted from a synchrotron ring by a resonant slow extraction method, and ultimately delivered to a patient through a beam-delivery system. At Japan's Gunma University, a method employing slow-beam extraction along with beam-acceleration has been adopted. This method slightly alters the extracted-beam's energy owing to the acceleration component of the process, which subsequently results in a residual-range variation of approximately 2 mm in water-equivalent length. However, this range variation does not disturb a distal dose distribution with broad-beam methods such as the single beam-wobbling method. With the pencil-beam 3D scanning method, however, such a range variation disturbs a distal dose distribution because the variation is comparable to slice thickness. Therefore, for pencil-beam 3D scanning, an energy compensation method for a slow extracted beam is proposed in this paper. This method can compensate for the aforementioned energy variances by controlling net energy losses through a rotatable energy absorber set fixed between the synchrotron exit channel and the isocenter. Experimental results demonstrate that beam energies can be maintained constant, as originally hypothesized. Moreover, energy-absorber positions were found to be significantly enhanced by optimizing beam optics for reducing beam-size growth by implementation of the multiple-scattering effect option.

  2. A comparative study of carbon-11 methionine PET and Fluorine-18 fluorodeoxyglucose PET for the differentiation of benign lesion and low grade glioma%11碳-蛋氨酸与18氟-脱氧葡萄糖在脑良性病变及低级别胶质瘤诊断中的比较

    Institute of Scientific and Technical Information of China (English)

    王欣璐; 韩立新; 尹吉林; 王成; 姜丽莎; 谭思婷; 王伟民

    2015-01-01

    界的显示均明显优于18 F-FDG FDG,11 C-MET 还可检测和随访低级别胶质瘤(即惰性肿瘤)的生长情况,可为临床提供更多诊断、预后及治疗信息,因此,11 C-MET 可常规应用于脑内占位病变的显示,且其效果优于18 F-FDG.%Aim:As the study of Carbon-11 methionine (MET)and fluorine-18 fluorodeoxyglucose (FDG)in differentiating brain benign and low grade glioma was seldom.The aim of this study was to de-termine the effect of these two tracers for distinguishing two groups of patients and evaluating the extent of lesions.Methods:Both carbon-11 MET and fluorine-18 FDG have been used to evaluate brain benign and low grade glioma (LGG).MET positron emission tomography (PET)and FDG PET were all per-formed in 22 patients (5 brain benign lesions,17 low grade glioma WHO grade I and II)within one week for a single patient,Both MET and FDG uptake of the lesions were evaluated by a semiquantitative analy-sis using the standardized uptake value.The Tumor/normal brain uptake ratio (T/N ratio)were calculat-ed in two groups of patients.Results:MET uptake was not significantly different among these two groups (benign:1.59 ±0.28 and LGG:1.52 ±0.48).Similarily,FDG uptake was not significantly different among the two groups (benign:0.91 ±0.48 and 0.77 ±0.65)also.No significantly correlation was ob-served between MET uptake and FDG uptake.19 /22 hypermetabolization of patients were found in MET PET and 17 /22 hypometabolization of patients were found in FDG PET.The extents of increased MET uptake in 17 cases were larger than that of the increased FDG uptake.Conclusion:It is found that both MET and FDG are not useful for distinguishing with benign and LGG.MET was found to be highly useful for detecting benign and LGG,and for evaluating the extent of these lesions which were blurred in FDG PET.MET was also useful for monitoring the growth of LGG.In a word,MET was considered as routine examination for brain lesions.

  3. E11 in 11D

    CERN Document Server

    Tumanov, Alexander

    2016-01-01

    We construct the non-linear realisation of the semi-direct product of E11 and its vector representation in eleven dimensions and find the dynamical equations it predicts at low levels. These equations are completely determined by the non-linear realisation and when restricted to contain only the usual fields of supergravity and the usual space-time we find precisely the equations of motion of eleven dimensional supergravity. This paper extends the results announced in arXiv:1512.01644 and in particular it contains the contributions to the equations of motion that involve derivatives with respect to the level one generalised coordinates.

  4. E11 in 11D

    Science.gov (United States)

    Tumanov, Alexander G.; West, Peter

    2016-07-01

    We construct the non-linear realisation of the semi-direct product of E11 and its vector representation in eleven dimensions and find the dynamical equations it predicts at low levels. These equations are completely determined by the non-linear realisation and when restricted to contain only the usual fields of supergravity and the usual spacetime we find precisely the equations of motion of eleven dimensional supergravity. This paper extends the results announced in arxiv:hep-th/1512.01644 and in particular it contains the contributions to the equations of motion that involve derivatives with respect to the level one generalised coordinates.

  5. Beam-beam effects in the Tevatron

    Energy Technology Data Exchange (ETDEWEB)

    Shiltsev, V.; Alexahin, Y.; Lebedev, V.; Lebrun, P.; Moore, R.S.; Sen, T.; Tollestrup, A.; Valishev, A.; Zhang, X.L.; /Fermilab

    2005-01-01

    The Tevatron in Collider Run II (2001-present) is operating with 6 times more bunches, many times higher beam intensities and luminosities than in Run I (1992-1995). Electromagnetic long-range and head-on interactions of high intensity proton and antiproton beams have been significant sources of beam loss and lifetime limitations. We present observations of the beam-beam phenomena in the Tevatron and results of relevant beam studies. We analyze the data and various methods employed in operations, predict the performance for planned luminosity upgrades, and discuss ways to improve it.

  6. Beam Instrumentation Global Network [BIGNET]: a common web portal for Beam instrumentalists

    CERN Document Server

    Gras, J-J

    2012-01-01

    This document will present an initiative launched during the International Particle Accelerator Conference (IPAC11) to define and produce a common web portal for Beam Instrumentation, with the aim of allowing any beam instrumentalist to easily and efficiently: - find the laboratories with machines using beams of similar characteristics (particle type, total beam intensity, bunch intensity, frequency, energy) - find the person who is working there on the beam observable concerned (i.e. beam position, loss, intensity, transverse or longitudinal profile, tune) and how to contact him/her - create discussion forums with the right audience on hot beam instrumentation topics or issues - advertise topical events and workshop - provide links towards documents describing system designs and performance assessments... This document will cover the status and prospects of the project with the aim to invite and welcome new laboratories to join the adventure.

  7. Electron-beam-fusion progress report, January--June 1976

    International Nuclear Information System (INIS)

    Research progress is reported for the following areas: (1) Proto I, (2) Proto II, (3) EBFA, (4) power flow, (5) contract progress reports, (6) progress in the Sandia program, (7) repetitively operated pulse generator development, (8) electron beam power from inductive storage, (9) fusion target design, (10) beam physics research, (11) power flow, (12) heavy ion fusion, (13) particle beam source development, (14) beam target interaction and target response studies, (15) diagnostic development, and (16) hybrid systems

  8. Electron beam pumped semiconductor laser

    Science.gov (United States)

    Hug, William F. (Inventor); Reid, Ray D. (Inventor)

    2009-01-01

    Electron-beam-pumped semiconductor ultra-violet optical sources (ESUVOSs) are disclosed that use ballistic electron pumped wide bandgap semiconductor materials. The sources may produce incoherent radiation and take the form of electron-beam-pumped light emitting triodes (ELETs). The sources may produce coherent radiation and take the form of electron-beam-pumped laser triodes (ELTs). The ELTs may take the form of electron-beam-pumped vertical cavity surface emitting lasers (EVCSEL) or edge emitting electron-beam-pumped lasers (EEELs). The semiconductor medium may take the form of an aluminum gallium nitride alloy that has a mole fraction of aluminum selected to give a desired emission wavelength, diamond, or diamond-like carbon (DLC). The sources may be produced from discrete components that are assembled after their individual formation or they may be produced using batch MEMS-type or semiconductor-type processing techniques to build them up in a whole or partial monolithic manner, or combination thereof.

  9. Beam halo in high-intensity beams

    International Nuclear Information System (INIS)

    In space-charge dominated beams the nonlinear space-charge forces produce a filamentation pattern, which in projection to the 2-D phase spaces results in a 2-component beam consisting of an inner core and a diffuse outer halo. The beam-halo is of concern for a next generation of cw, high-power proton linacs that could be applied to intense neutron generators for nuclear materials processing. The author describes what has been learned about beam halo and the evolution of space-charge dominated beams using numerical simulations of initial laminar beams in uniform linear focusing channels. Initial results are presented from a study of beam entropy for an intense space-charge dominated beam

  10. Enhanced radiosyntheses of [11C]raclopride and [11C]DASB using ethanolic loop chemistry

    International Nuclear Information System (INIS)

    Introduction: To improve the synthesis and quality control of carbon-11 labeled radiopharmaceuticals, we report the fully automated loop syntheses of [11C]raclopride and [11C]DASB using ethanol as the only organic solvent for synthesis module cleaning, carbon-11 methylation, HPLC purification, and reformulation. Methods: Ethanolic loop chemistry is fully automated using a GE TRACERLab FXC-Pro synthesis module, and is readily adaptable to any other carbon-11 synthesis apparatus. Precursors (1 mg) were dissolved in ethanol (100 μL) and loaded into the HPLC loop. [11C]MeOTf was passed through the HPLC loop and then the labeled products were purified by semi-preparative HPLC and reformulated into ethanolic saline. Results: Both [11C]raclopride (3.7% RCY; > 95% RCP; SA = 20831 Ci/mmol; n = 64) and [11C]DASB, both with (3.0% RCY; > 95% RCP; SA = 15152 Ci/mmol; n = 9) and without (3.0% RCY; > 95% RCP; SA = 10931 Ci/mmol; n = 3) sodium ascorbate, have been successfully prepared using the described methodology. Doses are suitable for human use and the described methods are now employed for routine clinical production of both radiopharmaceuticals at University of Michigan. Conclusions: Ethanolic loop chemistry is a powerful technique for preparing [11C]raclopride and [11C]DASB, and we are in the process of adapting it for other carbon-11 radiopharmaceuticals prepared in our laboratories ([11C]PMP, [11C]PBR28 etc.).

  11. Dosimetric precision of an ion beam tracking system

    International Nuclear Information System (INIS)

    Scanned ion beam therapy of intra-fractionally moving tumors requires motion mitigation. GSI proposed beam tracking and performed several experimental studies to analyse the dosimetric precision of the system for scanned carbon beams. A beam tracking system has been developed and integrated in the scanned carbon ion beam therapy unit at GSI. The system adapts pencil beam positions and beam energy according to target motion. Motion compensation performance of the beam tracking system was assessed by measurements with radiographic films, a range telescope, a 3D array of 24 ionization chambers, and cell samples for biological dosimetry. Measurements were performed for stationary detectors and moving detectors using the beam tracking system. All detector systems showed comparable data for a moving setup when using beam tracking and the corresponding stationary setup. Within the target volume the mean relative differences of ionization chamber measurements were 0.3% (1.5% standard deviation, 3.7% maximum). Film responses demonstrated preserved lateral dose gradients. Measurements with the range telescope showed agreement of Bragg peak depth under motion induced range variations. Cell survival experiments showed a mean relative difference of -5% (-3%) between measurements and calculations within the target volume for beam tracking (stationary) measurements. The beam tracking system has been successfully integrated. Full functionality has been validated dosimetrically in experiments with several detector types including biological cell systems

  12. Dosimetric precision of an ion beam tracking system

    Directory of Open Access Journals (Sweden)

    Kraft Gerhard

    2010-06-01

    Full Text Available Abstract Background Scanned ion beam therapy of intra-fractionally moving tumors requires motion mitigation. GSI proposed beam tracking and performed several experimental studies to analyse the dosimetric precision of the system for scanned carbon beams. Methods A beam tracking system has been developed and integrated in the scanned carbon ion beam therapy unit at GSI. The system adapts pencil beam positions and beam energy according to target motion. Motion compensation performance of the beam tracking system was assessed by measurements with radiographic films, a range telescope, a 3D array of 24 ionization chambers, and cell samples for biological dosimetry. Measurements were performed for stationary detectors and moving detectors using the beam tracking system. Results All detector systems showed comparable data for a moving setup when using beam tracking and the corresponding stationary setup. Within the target volume the mean relative differences of ionization chamber measurements were 0.3% (1.5% standard deviation, 3.7% maximum. Film responses demonstrated preserved lateral dose gradients. Measurements with the range telescope showed agreement of Bragg peak depth under motion induced range variations. Cell survival experiments showed a mean relative difference of -5% (-3% between measurements and calculations within the target volume for beam tracking (stationary measurements. Conclusions The beam tracking system has been successfully integrated. Full functionality has been validated dosimetrically in experiments with several detector types including biological cell systems.

  13. Beam imaging sensor

    Energy Technology Data Exchange (ETDEWEB)

    McAninch, Michael D.; Root, Jeffrey J.

    2016-07-05

    The present invention relates generally to the field of sensors for beam imaging and, in particular, to a new and useful beam imaging sensor for use in determining, for example, the power density distribution of a beam including, but not limited to, an electron beam or an ion beam. In one embodiment, the beam imaging sensor of the present invention comprises, among other items, a circumferential slit that is either circular, elliptical or polygonal in nature.

  14. Focusing upgrade for sectors 11 through 19

    International Nuclear Information System (INIS)

    In order to transport high current, single bunch beams to the SLC positron source for spring 1986 testing, it will be necessary to augment the strength of available focusing in sectors 11 through 19. We have decided to replace the sector doublet type QB quadrupoles with stronger type QE magnets. In conjunction with new Vax controlled power supplies, this sector 11 through 19 doublet lattice can be run at optimal settings for beam energies of several GeV up to the full SLC energy of 32 GeV by sector 19. Installation of the temporary stronger focusing is planned for summer 1985; full SLC FODO array focusing is scheduled for the following summer. This note presents the intermediate solution for sectors 11 through 19. In addition, the sector 10 quadrupole strengths required for matching beams into the doublet array are given. 1 figure, 4 tables

  15. Short-lived positron emitters in beam-on PET imaging during proton therapy

    International Nuclear Information System (INIS)

    The only method for in vivo dose delivery verification in proton beam radiotherapy in clinical use today is positron emission tomography (PET) of the positron emitters produced in the patient during irradiation. PET imaging while the beam is on (so called beam-on PET) is an attractive option, providing the largest number of counts, the least biological washout and the fastest feedback. In this implementation, all nuclides, independent of their half-life, will contribute. As a first step towards assessing the relevance of short-lived nuclides (half-life shorter than that of 10C, T1/2  =  19 s) for in vivo dose delivery verification using beam-on PET, we measured their production in the stopping of 55 MeV protons in water, carbon, phosphorus and calcium The most copiously produced short-lived nuclides and their production rates relative to the relevant long-lived nuclides are: 12N (T1/2  =  11 ms) on carbon (9% of 11C), 29P (T1/2  =  4.1 s) on phosphorus (20% of 30P) and 38mK (T1/2  =  0.92 s) on calcium (113% of 38gK). No short-lived nuclides are produced on oxygen. The number of decays integrated from the start of an irradiation as a function of time during the irradiation of PMMA and 4 tissue materials has been determined. For (carbon-rich) adipose tissue, 12N dominates up to 70 s. On bone tissue, 12N dominates over 15O during the first 8–15 s (depending on carbon-to-oxygen ratio). The short-lived nuclides created on phosphorus and calcium provide 2.5 times more beam-on PET counts than the long-lived ones produced on these elements during a 70 s irradiation. From the estimated number of 12N PET counts, we conclude that, for any tissue, 12N PET imaging potentially provides equal to superior proton range information compared to prompt gamma imaging with an optimized knife-edge slit camera. The practical implementation of 12N PET imaging is discussed. (paper)

  16. Short-lived positron emitters in beam-on PET imaging during proton therapy

    Science.gov (United States)

    Dendooven, P.; Buitenhuis, H. J. T.; Diblen, F.; Heeres, P. N.; Biegun, A. K.; Fiedler, F.; van Goethem, M.-J.; van der Graaf, E. R.; Brandenburg, S.

    2015-12-01

    The only method for in vivo dose delivery verification in proton beam radiotherapy in clinical use today is positron emission tomography (PET) of the positron emitters produced in the patient during irradiation. PET imaging while the beam is on (so called beam-on PET) is an attractive option, providing the largest number of counts, the least biological washout and the fastest feedback. In this implementation, all nuclides, independent of their half-life, will contribute. As a first step towards assessing the relevance of short-lived nuclides (half-life shorter than that of 10C, T1/2  =  19 s) for in vivo dose delivery verification using beam-on PET, we measured their production in the stopping of 55 MeV protons in water, carbon, phosphorus and calcium The most copiously produced short-lived nuclides and their production rates relative to the relevant long-lived nuclides are: 12N (T1/2  =  11 ms) on carbon (9% of 11C), 29P (T1/2  =  4.1 s) on phosphorus (20% of 30P) and 38mK (T1/2  =  0.92 s) on calcium (113% of 38gK). No short-lived nuclides are produced on oxygen. The number of decays integrated from the start of an irradiation as a function of time during the irradiation of PMMA and 4 tissue materials has been determined. For (carbon-rich) adipose tissue, 12N dominates up to 70 s. On bone tissue, 12N dominates over 15O during the first 8-15 s (depending on carbon-to-oxygen ratio). The short-lived nuclides created on phosphorus and calcium provide 2.5 times more beam-on PET counts than the long-lived ones produced on these elements during a 70 s irradiation. From the estimated number of 12N PET counts, we conclude that, for any tissue, 12N PET imaging potentially provides equal to superior proton range information compared to prompt gamma imaging with an optimized knife-edge slit camera. The practical implementation of 12N PET imaging is discussed.

  17. A symplectic coherent beam-beam model

    International Nuclear Information System (INIS)

    We consider a simple one-dimensional model to study the effects of the beam-beam force on the coherent dynamics of colliding beams. The key ingredient is a linearized beam-beam kick. We study only the quadrupole modes, with the dynamical variables being the 2nd-order moments of the canonical variables q, p. Our model is self-consistent in the sense that no higher order moments are generated by the linearized beam-beam kicks, and that the only source of violation of symplecticity is the radiation. We discuss the round beam case only, in which vertical and horizontal quantities are assumed to be equal (though they may be different in the two beams). Depending on the values of the tune and beam intensity, we observe steady states in which otherwise identical bunches have sizes that are equal, or unequal, or periodic, or behave chaotically from turn to turn. Possible implications of luminosity saturation with increasing beam intensity are discussed. Finally, we present some preliminary applications to an asymmetric collider. 8 refs., 8 figs

  18. Literature in Focus Beta Beams: Neutrino Beams

    CERN Multimedia

    2009-01-01

    By Mats Lindroos (CERN) and Mauro Mezzetto (INFN Padova, Italy) Imperial Press, 2009 The beta-beam concept for the generation of electron neutrino beams was first proposed by Piero Zucchelli in 2002. The idea created quite a stir, challenging the idea that intense neutrino beams only could be produced from the decay of pions or muons in classical neutrino beams facilities or in future neutrino factories. The concept initially struggled to make an impact but the hard work by many machine physicists, phenomenologists and theoreticians over the last five years has won the beta-beam a well-earned position as one of the frontrunners for a possible future world laboratory for high intensity neutrino oscillation physics. This is the first complete monograph on the beta-beam concept. The book describes both technical aspects and experimental aspects of the beta-beam, providing students and scientists with an insight into the possibilities o...

  19. Structure-Processing-Property Relationships at the Fiber-Matrix Interface in Electron-Beam Cured Composite Materials

    Energy Technology Data Exchange (ETDEWEB)

    Janke, C.J.

    1998-11-01

    The objective of this project was to characterize the properties of the resin and the fiber- resin interface in electron beam cured materials by evaluating several structural and processing parameters. The Oak Ridge National Laboratory (ORNL) has recently determined that the interlaminar shear strength properties of electron beam cured composites were 19-28% lower than for autoclave cured composites. Low interlaminar shear strength is widely acknowledged as the key barrier to the successfid acceptance and implementation of electron beam cured composites in industry. In this project we found that simple resin modification and process improvements are unlikely to substantially improve the interlaminar shear strength properties of electron beam cured composites. However, sizings and coatings were shown to improve these properties and there appears to be significant potential for further improvement. In this work we determined that the application of epoxy-based, electron beam compatible sizings or coatings onto surface- treated, unsized carbon fibers improved the composite interlaminar shear strength by as much as 55% compared to composites fabricated from surface-treated, unsized carbon fibers and 11 YO compared to composites made from surface-treated, GP sized carbon fibers. This work has identified many promising pathways for increasing the interlaminar shear strength of electron beam cured composites. As a result of these promising developments we have recently submitted a U.S. Department of Energy-Energy Research (DOE-ER) sponsored Laboratory Technical Research-Cooperative Research and Development Agreement (LTR- CRADA) proposal entitled, "Interracial Properties of Electron Beam Cured Composites", to continue this work. If funded, ORNL will lead a 3-year, $2.6 million effort involving eight industrial partners, NASA-Langley, and the U.S. Air Force. The principal objective of this CRADA is to significantly improve the interracial properties of carbon

  20. Telecommunication using muon beams

    Science.gov (United States)

    Arnold, Richard C.

    1976-01-01

    Telecommunication is effected by generating a beam of mu mesons or muons, varying a property of the beam at a modulating rate to generate a modulated beam of muons, and detecting the information in the modulated beam at a remote location.