WorldWideScience

Sample records for carbon 10 beams

  1. Current density profile and electron beam localization measurements using carbon pellets on T-10

    International Nuclear Information System (INIS)

    The letter presents experimental evidence and an analysis of two phenomena arising during carbon pellet ablation - a toroidal trajectory deflection and enhanced localized ablation in the electron cyclotron resonance (ECR) current drive regime. A model developed for describing the toroidal deflection of a carbon pellet in a tokamak shows that the trajectory curvature is sensitive to the current density. Photography of the pellet trajectory is used as a diagnostic for the determination of the local current density in an ohmically heated plasma. Directly measured current profiles using pellets are in reasonable agreement with that obtained using the Spitzer conductivity, and current density fluctuations have been observed that are probably associated with magnetic islands. It is shown that in the ECR current drive regime on T-10, energetic electrons probably stimulated by the microwave power are located in a narrow zone (2 cm thickness in the radial direction) with sharp boundaries. (author). Letter-to-the-editor. 7 refs, 5 figs

  2. LETTER: Current density profile and electron beam localization measurements using carbon pellets on T-10

    Science.gov (United States)

    Egorov, S. M.; Kuteev, B. V.; Miroshnikov, I. V.; Mikhailenko, A. A.; Sergeev, V. Yu.; Ushakov, S. N.; Bagdasarov, A. A.; Chistyakov, V. V.; Elizavetin, D. Yu.; Vasin, N. L.

    1992-11-01

    The authors present experimental evidence and an analysis of two phenomena arising during carbon pellet ablation-a toroidal trajectory deflection and enhanced localized ablation in the electron cyclotron resonance (ECR) current drive regime. A model developed for describing the toroidal deflection of a carbon pellet in a tokamak shows that the trajectory curvature is sensitive to the current density. Photography of the pellet trajectory is used as a diagnostic for the determination of the local current density in an ohmically heated plasma. Directly measured current profiles using pellets are in reasonable agreement with that obtained using the Spitzer conductivity, and current density fluctuations have been observed that are probably associated with magnetic islands. It is shown that in the ECR current drive regime on T-10, energetic electrons probably stimulated by the microwave power are located in a narrow zone (2 cm thickness in the radial direction) with sharp boundaries

  3. Fragmentation in Carbon Therapy Beams

    CERN Document Server

    Charara, Y M

    2010-01-01

    The state of the art Monte Carlo code HETC-HEDS was used to simulate spallation products, secondary neutron, and secondary proton production in A-150 Tissue Equivalent Plastic phantoms to investigate fragmentation of carbon therapy beams. For a 356 MeV/Nucleon carbon ion beam, production of charged particles heavier than protons was 0.24 spallation products per incident carbon ion with atomic numbers ranging from 1 through 5 (hydrogen to boron). In addition, there were 4.73 neutrons and 2.95 protons produced per incident carbon ion. Furthermore, as the incident energy increases, the neutron production rate increases at a rate of 20% per 10 MeV/nucleon. Secondary protons were created at a rate between 2.62-2.87 per carbon ion, while spallation products were created at a rate between 0.20-0.24 per carbon ion.

  4. Carbon beam dosimetry using VIP polymer gel and MRI

    DEFF Research Database (Denmark)

    Kantemiris, I; Petrokokkinos, L; Angelopoulos, A;

    2009-01-01

    VIP polymer gel dosimeter was used for Carbon ion beam dosimetry using a 150 MeV/n beam with 10 Gy plateau dose and a SOBP irradiation scheme with 5 Gy Bragg peak dose. The results show a decrease by 8 mm in the expected from Monte Carlo simulation range in water, suggesting that the dosimeter is...

  5. Carbon beams, production and acceleration

    International Nuclear Information System (INIS)

    Installation, test and working conditions of a new negative-ion facility of the Salazar EN tandem are briefly described. Carbon is the material used for the test and the heavy ion stripping phenomenon is reviewed. (author)

  6. Plasma beam discharge in carbon dioxide

    International Nuclear Information System (INIS)

    The paper deals with the dissociation of carbon dioxide in nonequilibrium plasma of a stationary plasma-beam discharge. Experimental results of spectroscopic and probe measurements of plasma parameters are given. Moreover, a mass-spectrometric analysis of gaseous products of the chemical reactions is presented. In addition the measurement of the deposition rate of solid products by means of a quartz oscillator is described. The results show that plasma beam discharge is an effective tool for inducing plasma-chemical reactions. (author)

  7. Carbon Fiber Damage in Particle Beam

    CERN Document Server

    Dehning, B; Kroyer, T; Meyer, M; Sapinski, M

    2011-01-01

    Carbon fibers are commonly used as moving targets in beam wire scanners. The heating of the fiber due to energy loss of the particles travelling through is simulated with Geant4. The heating induced by the beam electromagnetic field is estimated with ANSYS. The heat transfer and sublimation processes are modelled. Due to the model nonlinearity, a numerical approach based on discretization of the wire movement is used to solve it for particular beams. Radiation damage to the fiber is estimated with SRIM. The model is tested with available SPS and LEP data and a dedicated damage test on the SPS beam is performed followed by a post-mortem analysis of the wire remnants. Predictions for the LHC beams are made.

  8. Electron beam processing of carbon fibre reinforced braided composites beams

    International Nuclear Information System (INIS)

    Complete text of publication follows. In this paper the possibility of producing a new type carbon fiber reinforced composite is examined by applying braiding, a well-known process of textile technology. The appearance of the new Hungarian carbon fiber with excellent mechanical properties in the market enables the development of newer type carbon fiber reinforced composites in the continuously widening range of engineering applications. Advanced hollow profiles, pipes and other composite products can be manufactured in continuous operation. A new way of composite production of this kind is the manufacturing of reinforcing structure by braiding technology producing a composite with sufficient mechanical properties from this cross directional fabric-like textile structure by impregnation. This manufacturing process can complete the variety of hollow products serving the same purpose as pultrusion or filament winding. This way a profile type framework element with a hollow cross section is manufactured having favorable mechanical properties. Owing to its small mass and high specific strength this product can be applied in dynamically loaded structures e.g. in the automotive industry. For crosslinking of the matrix the method of high-speed electron beam curing has been examined in order to reach continuous operation. The field of use and application of carbon fiber braided structures has a great chance especially in machine engineering and in the automotive industry. The main reason for this is that braiding processes are capable of producing structures having good mechanical properties at a low processing price. The mass of the composite load-bearing structure produced this way is one fifth of the steel product having similar geometry, and its specific mechanical properties are nearly as good as that of the most commonly applied semiproduct and structural component, the welded steel profile

  9. Intensive irradiation of carbon nanotubes by Si ion beam

    Institute of Scientific and Technical Information of China (English)

    NI Zhichun; LI Qintao; YAN Long; GONG Jinlong; ZHU Dezhang; ZHU Zhiyuan

    2007-01-01

    Multi-walled carbon nanotubes were irradiated with 40 keV Si ion beam to a dose of 1×1017 cm-2. The multiple-way carbon nanowire junctions and the Si doping in carbon nanowires were realized. Moreover, the formation processes of carbon nanowire junctions and the corresponding mechanism were studied.

  10. Shunting arc plasma source for pure carbon ion beam

    Energy Technology Data Exchange (ETDEWEB)

    Koguchi, H.; Sakakita, H.; Kiyama, S.; Shimada, T.; Sato, Y.; Hirano, Y. [Energy Technology Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan)

    2012-02-15

    A plasma source is developed using a coaxial shunting arc plasma gun to extract a pure carbon ion beam. The pure carbon ion beam is a new type of deposition system for diamond and other carbon materials. Our plasma device generates pure carbon plasma from solid-state carbon material without using a hydrocarbon gas such as methane gas, and the plasma does not contain any hydrogen. The ion saturation current of the discharge measured by a double probe is about 0.2 mA/mm{sup 2} at the peak of the pulse.

  11. Shunting arc plasma source for pure carbon ion beam.

    Science.gov (United States)

    Koguchi, H; Sakakita, H; Kiyama, S; Shimada, T; Sato, Y; Hirano, Y

    2012-02-01

    A plasma source is developed using a coaxial shunting arc plasma gun to extract a pure carbon ion beam. The pure carbon ion beam is a new type of deposition system for diamond and other carbon materials. Our plasma device generates pure carbon plasma from solid-state carbon material without using a hydrocarbon gas such as methane gas, and the plasma does not contain any hydrogen. The ion saturation current of the discharge measured by a double probe is about 0.2 mA∕mm(2) at the peak of the pulse. PMID:22380206

  12. 10 MeV Medical Cyclotron Prototype Beam Commissioning

    Institute of Scientific and Technical Information of China (English)

    GUAN; Feng-ping; GE; Tao; YIN; Zhi-guo; SONG; Guo-fang; ZHANG; Tian-jue; JI; Bin; LI; Peng-zhan; CAO; Lei; HOU; Shi-gang; LIU; Geng-shou; WANG; Feng; LEI; Yu; WU; Long-cheng; WEN; Li-peng; LI; Zhen-guo; CUI; Tao; JIA; Xian-lu; YAO; Hong-juan; PAN; Gao-feng; ZHANG; Su-ping; CAI; Hong-ru; XIE; Huai-dong

    2012-01-01

    <正>A 10 MeV medical cyclotron prototype for the production of short-lived isotopes has been developed independently at CIAE with a time span of 2 years. On the inner target, 8 hours stability test has been finished. The extraction beam is 10 MeV with a beam intensity of 100 μA.

  13. Beam transport system selection on the accelerator LU-10

    International Nuclear Information System (INIS)

    Presently at the NSC KIPT the upgrading of the linear accelerator LU-10, designed for radiation processing of materials and products within the range of about 10 MeV, is started. For the accelerator operation time be used more efficiently it is supposed to design the second beam output onto the target. Possible variants of the second channel have been considered. The beam characteristics and beam losses are calculated with taking into account the desired parameters of the beam at the accelerating section output. Analysis of some channel variants by various criteria has been performed. The most effective version is chosen

  14. Improvement of carbon fiber surface properties using electron beam irradiation

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Carbon fiber-reinforced advance composites have been used for struetural applications, mainly on account of their mechanical properties. The main factor for a good mechanical performance of carbon fiber-reinforced composite is the interfacial interaction between its components, which are carbon fiber and polymeric matrix. The aim of this study is to improve the surface properties of the carbon fiber using ionizing radiation from an electron beam to obtain better adhesion properties in the resultant composite. EB radiation was applied on the carbon fiber itself before preparing test specimens for the mechanical tests. Experimental results showed that EB irradiation improved the tensile strength of carbon fiber samples. The maximum value in tensile strength was reached using doses of about 250kGy. After breakage, the morphology aspect of the tensile specimens prepared with irradiated and non-irradiated carbon fibers were evaluated. SEM micrographs showed modifications on the carbon fiber surface.

  15. Modeling the Biophysical Effects in a Carbon Beam Delivery Line using Monte Carlo Simulation

    CERN Document Server

    Cho, Ilsung; Cho, Sungho; Kim, Eun Ho; Song, Yongkeun; Shin, Jae-ik; Jung, Won-Gyun

    2016-01-01

    Relative biological effectiveness (RBE) plays an important role in designing a uniform dose response for ion beam therapy. In this study the biological effectiveness of a carbon ion beam delivery system was investigated using Monte Carlo simulation. A carbon ion beam delivery line was designed for the Korea Heavy Ion Medical Accelerator (KHIMA) project. The GEANT4 simulation tool kit was used to simulate carbon beam transporting into media. An incident energy carbon ion beam in the range between 220 MeV/u and 290 MeV/u was chosen to generate secondary particles. The microdosimetric-kinetic (MK) model is applied to describe the RBE of 10% survival in human salivary gland (HSG) cells. The RBE weighted dose was estimated as a function of the penetrating depth of the water phantom along the incident beam direction. A biologically photon-equivalent Spread Out Bragg Peak (SOBP) was designed using the RBE weighted absorbed dose. Finally, the RBE of mixed beams was predicted as a function of the water phantom depth.

  16. Mechanical and tribological properties of carbon thin film with tungsten interlayer prepared by Ion beam assisted deposition

    Czech Academy of Sciences Publication Activity Database

    Vlčák, P.; Černý, F.; Tolde, Z.; Sepitka, J.; Gregora, Ivan; Daniš, S.

    2013-01-01

    Roč. 2013, FEB (2013). ISSN 2314-4874 Institutional support: RVO:68378271 Keywords : carbon coatings * ion beam deposition * XRD * nanoindentation Subject RIV: BM - Solid Matter Physics ; Magnetism http://dx.doi.org/10.1155/2013/630156

  17. Carbon Beam Radio-Therapy and Research Activities at HIMAC

    International Nuclear Information System (INIS)

    Radio-therapy with carbon ion beam has been carried out since 1994 at HIMAC (Heavy Ion Medical Accelerator in Chiba) in NIRS (National Institute of Radiological Sciences). Now, many types of tumors can be treated with carbon beam with excellent local controls of the tumors. Stimulated with good clinical results, requirement of the dedicated compact facility for carbon beam radio-therapy is increased. To realize this requirement, design study of the facility and the R and D's of the key components in this design are promoted by NIRS. According successful results of these activities, the dedicated compact facility will be realized in Gunma University. In this facility, the established irradiation method is expected to use, which is passive irradiation method with wobbler magnets and ridge filter. In this presentation, above R and D's will be presented together with clinical results and basic research activities at HIMAC

  18. Radiation sterilization by 10 MeV electron beams

    International Nuclear Information System (INIS)

    Gamma-ray sterilization by 60Co source has been already popular in Japan. Many Kinds of medical plastic devices such as catheters, disposable syringes, dializers etc, has been irradiated at 60Co irradiation facilities instead of the conventional ethylene oxide fumigation method. On the other hand, improvement of the quality of electron accelerators has made it easier to take advantage of relatively high energy electrons which are profitable for radiation sterilization because of their high dose rate saving process hours and easiness of source handling and radiation control. So electron-beam sterilization is now under investigation in Japan and, partly, it will be practiced in the near future. Yet few data are available in the present situation. Especially for high energy electron beams near 10 MeV, more data are necessary for practical application of electron-beam sterilization. Therefore, in this study, sensitivity of Bacillus pumilus E601, the biological standard of radiation sterilization, was examined using 10 MeV electron beams from linear accelerator and sterility of the beams was also checked at each depth of plastic boards in order to get basic information for determination of sterility dose. Endospores from B. pumilus were dried on filter papers (Toyo No.1) and irradiated by 10 MeV electron beams of 60Co gamma-rays. The survival curves were shown in Fig. 1. The D values were obtained as 1.9 kGy ± 0.2 for electron beams and 1.7 kGy ± 0.1 for 60Co gamma-rays, both of which were similar. Electron beams could sterilize the endospores nearly uniformly till 3 cm depth of plastic boards at 10 MeV (Fig. 2,3). This indicates a possibility to sterilize relatively bulky products such as dializers etc. (author)

  19. FIDDLING CARBON STRINGS WITH POLARIZED PROTON BEAMS.

    Energy Technology Data Exchange (ETDEWEB)

    HUANG, H.; KURITA, K.

    2006-05-01

    An innovative polarimeter based on proton carbon elastic scattering in the Coulomb Nuclear Interference (CNI) region was first tested in the Brookhaven AGS successfully. CNI Polarimeters were then installed in the AGS and both RHIC rings. The polarimeter consists of ultra-thin carbon targets and silicon strip detectors. The waveform digitizers are used for signal readout, which allows deadtime-less data processing on the fly. Polarimeters are crucial instrumentation for the RHIC spin physics program. This paper summarizes the polarimeter design issues and operation results.

  20. Blister formation in tungsten by hydrogen and carbon mixed ion beam irradiation

    International Nuclear Information System (INIS)

    Blister formation in tungsten has been studied by mixed carbon and hydrogen ion beam irradiation. The beam ion energies were 1.0 keV and 300 eV, and the fluence was in the range of 1024-1025 ions m-2. It was found that a little amount of carbon impurity in the beam affected blister formation. A large number of blisters with various sizes were observed on the surface of tungsten at 653 K when the carbon concentration was more than 0.35%. When the carbon concentration was 0.11%, no blisters larger than 1.0 μm were observed. When the carbon concentration was 2.35%, a carbon layer developed on the tungsten surface, and again, no blisters were observed. The effect of target temperature on blister formation was also investigated: the sizes and numbers of the blisters were the largest when the tungsten was irradiated at 653 K; when the sample was irradiated at 388 or 873 K, no blisters larger than 1.0 μm were observed

  1. Boron-10 prompt gamma analysis using a diffracted neutron beam

    International Nuclear Information System (INIS)

    A prompt gamma neutron activation analysis (PGNAA) facility has been built at the 5 MW MITR-II Research Reactor to support the ongoing boron neutron capture therapy (NCT) program. This facility is used to determine the concentration of B-10 in NCT relevant samples such as blood and urine. The B-10 concentration is needed to determine the radiation doses that tumor and healthy brain receive during neutron irradiation of a patient. Assaying for B-10 by PGNAA has several advantages over conventional chemical methods. It is rapid, accurate, nondestructive (allowing for re-analysis), inexpensive, sensitive (ppm level), generally independent of the chemical or physical matrix of the B-10, and does not require chemical manipulations of the sample. The authors goal was to build an inexpensive facility with a suitably high thermal neutron flux for PGNAA and a low level of photon and fast neutron contamination. Their design is unique in that it uses a diffracted beam. Most prompt gamma facilities use direct beams; these beams have a high thermal flux (> 107 n/cm2-sec), but are heavily contaminated with protons and fast neutrons. Other prompt gamma facilities use totally reflecting guide tubes; these beams have little contamination, but are expensive. The high thermal flux of direct beam facilities might not be an advantage since the detector usually must be moved further away from the sample to avoid high dead times in the multichannel analyzer

  2. Biological effect of carbon beams on cultured human cells

    International Nuclear Information System (INIS)

    This study was performed to determine the biological effect of carbon beams on 13 human tumor cells, in comparison with 200 KVp X-rays. Carbon beams were generated by the Riken Ring Cyclotron. The RBE (relative biological effectiveness) values were distributed from 1.46 to 2.20 for LET of 20 keV/μm, and 2.29-3.54 for 80 keV/μm. The RBEs were increased in all cell lines as the LET of carbon beams was increased from 20 to 80 keV/μm. There was no significant difference in radiosensitivity between cells from adenocarcinoma and those from squamous cell carcinoma. The relationship between the radiosensitivity of cells to X-rays and RBE was analyzed, but no significant correlation was suggested. Several survival curves of 20-40 keV/μm carbon beam irradiation showed the initial shoulders and the recovery ratios between two split doses were determined. Recovery was observed for LET of 2O keV/μm but not for that of 40 keV/μm. Furthermore, recovery ratios were 1.0-1.8, smaller than those for X-rays (1.5-2.4). (author)

  3. Optical transition radiation from a thin carbon foil: a beam profile monitor for the SLC

    International Nuclear Information System (INIS)

    This memo considers placement of an ultra thin carbon foil into the SLC beam. Transition radiation light would be emitted from the surface of the foil. The optical spot from the foil could be viewed with a microscope objective lens and registered with an image detector. Multiple scattering for the foil thicknesses necessary will not affect the beam emittance. Calculations show that a thin carbon foil can withstand the electron beam if the electron beam is larger than 10 μm in size. There are many possible radiation mechanisms from a foil - bremsstrahlung, black body temperature radiation, Cerenkov light, scintillation light, and transition radiation. Transition radiation is apparently dominant. It is proposed to use thin carbon foils, 75 to 150 A thick. Calculations indicate that 5 x 1010 beam electrons will radiate a useable number of optical photons. Specifically with 150 A foils the fractional yield of useful optical photons is 10-3 photons per incident electron 5 x 10+7 optical photons imaged upon an image plane. Spread these photons over a 32 x 32 pixel CCD and one has the readout system of a monitor

  4. Dose Response of Alanine Detectors Irradiated with Carbon Ion Beams

    DEFF Research Database (Denmark)

    Herrmann, Rochus; Jäkel, Oliver; Palmans, Hugo;

    2011-01-01

    Purpose: The dose response of the alanine detector shows a dependence on particle energy and type, when irradiated with ion beams. The purpose of this study is to investigate the response behaviour of the alanine detector in clinical carbon ion beams and compare the results with model predictions....... Methods: Alanine detectors have been irradiated with carbon ions with an energy range of 89-400 MeV/u. The relative effectiveness of alanine has been measured in this regime. Pristine and spread out Bragg peak depth-dose curves have been measured with alanine dosimeters. The track-structure based alanine...... response model developed by J. Hansen and K. Olsen has been implemented in the Monte Carlo code FLUKA, and calculations were compared with experimental results. Results: Calculations of the relative effectiveness deviate less than 5% from the measured values for mono energetic beams. Measured depth...

  5. Fabrication of carbon nanorod from the irradiation of proton beam on carbon nanotube and characterization of its resistance variation

    International Nuclear Information System (INIS)

    Fabrication method of the transparent carbon nanotubes film on the glass with the transparency of 50 ∼ 80 % and the sheet resistance of 500 ∼ 2000 Ω/sq is developed based on the established study of the enhancement of the conductivity. Deformation of the bundle-type single-walled carbon nanotubes are analyzed with the variation of the energy transfer in the carbon nanotubes by the variation of the dose of the 10 MeV proton beam. Construction of the variation of the conductivity of the carbon nanotube network and the variation of the transparency of the glass are used for the feasibility of the fabrication of the transparent electrode using carbon nanotubes network. Transparent carbon nanotubes film are fabricated using spray method and the sheet resistance and transparency are controlled by the control of the quantity of the dispersion. Accumulated energy on the carbon nanotubes are controlled by the dose of the 10 MeV proton. Proton irradiation creates defects on the carbon nanotubes by particle collision and the recombination of the defects generates the decrease of the diameter of the carbon nanotubes. Ejection of the carbon from the carbon nanotubes generates not only the formation of the connection between carbon nanotubes but also between carbon nanotube bundles. These connections decrease the resistance between carbon nanotube networks and 2.5 times increase is measured. Although the electrical conductivity is increased by the proton irradiation, sulfuration of the glass is increased. Variation of the transparency is caused by the positive ion irradiation and the transparency is decreased with the dose due to the increase of the energy transfer on the glass

  6. Design Study of a Superconducting Gantry for Carbon Beam Therapy

    CERN Document Server

    Kim, J

    2016-01-01

    This paper describes the design study of a gantry for a carbon beam. The designed gantry is compact such that its size is comparable to the size of the proton gantry. This is possible by introducing superconducting double helical coils for dipole magnets. The gantry optics is designed in such a way that it provides rotation-invariant optics and variable beam size as well as point-to-parallel scanning of a beam. For large-aperture magnet, three-dimensional magnetic field distribution is obtained by invoking a computer code, and a number of particles are tracked by integrating equations of motion numerically together with three-dimensional interpolation. The beam-shape distortion due to the fringe field is reduced to an acceptable level by optimizing the coil windings with the help of genetic algorithm. Higher-order transfer coefficients are calculated and shown to be reduced greatly with appropriate optimization of the coil windings.

  7. Beam tests of a 10 GHz compact ECR ion source

    International Nuclear Information System (INIS)

    Ion source for medical facilities should have characteristics of easy maintenance, low electric power, good stability and long operation time without maintenance (one year or more). The 10 GHz compact Electron Cyclotron Resonance (ECR) Ion Source with all permanent magnets has been developed 2003. The maximum mirror magnetic field on the beam axis are 0.59 T at the extraction side and 0.87 T at the gas injection side. The minimum B strength is 0.25 T. The size of the source is 300 mm in diameter and 290 mm in length. Details of the design and the results of preliminary beam test are reported. (author)

  8. HIGHLIGHTS LHC First Beam - Accelerating Science : 10 September 2008

    CERN Multimedia

    CERN Audiovisual Service

    2008-01-01

    First beam in the LHC - accelerating science A historic moment in the CERN Control Centre: the beam was successfully steered around the accelerator. Channel 1 : International Channel 2 : English guide A historic moment in the CERN Control Centre: the beam was successfully steered around the accelerator. Geneva, 10 September 2008. The first beam in the Large Hadron Collider at CERN1 was successfully steered around the full 27 kilometres of the world’s most powerful particle accelerator at 10h28 this morning. This historic event marks a key moment in the transition from over two decades of preparation to a new era of scientific discovery. “It’s a fantastic moment,” said LHC project leader Lyn Evans, “we can now look forward to a new era of understanding about the origins and evolution of the universe.” Starting up a major new particle accelerator takes much more than flipping a switch. Thousands of individual elements have to work in harmony, timings have to be synchronized to under a billionth of a...

  9. Practical biological spread-out Bragg peak design of carbon beam

    OpenAIRE

    Kim, Chang Hyeuk; Lee, Hwa-Ryun; Chang, Seduk; Jang, Hong Suk; Kim, Jeong Hwan; Park, Dong Wook; Hwang, Won Taek; Yang, Tea-Keun

    2015-01-01

    The carbon beams show more advantages on the biological properties compared with proton beams in radiation therapy. The carbon beam shows high linear energy transfer (LET) to medium and it increases the relative biological effectiveness (RBE). To design spread-out Bragg peak (SOBP) of biological dose using carbon beam, a practical method was purposed by using the linear-quadratic (LQ) model and Geant4 based Monte Carlo simulation code. The various Bragg peak profiles and LET was calculated fo...

  10. Response of SOI image sensor to therapeutic carbon ion beam

    CERN Document Server

    Matsumura, Akihiko

    2015-01-01

    Carbon ion radiotherapy is known as a less invasive cancer treatment. The radiation quality is an important parameter to evaluate the biological effect and the clinical dose from the measured physical dose. The performance of SOPHIAS detector, which is the SOI image sensor having a wide dynamic range and large active area, was tested by using therapeutic carbon ion beam at Gunma University Heavy Ion Medical Center (GHMC). It was shown that the primary carbon and secondary particles can be distinguishable by SOPHIAS detector. On the other hand, a LET dependence was observed especially at the high LET region. This phenomenon will be studied by using the device simulator together with Monte Carlo simulation.

  11. The thermal effect on vibration of single-walled carbon nanotubes using nonlocal Timoshenko beam theory

    International Nuclear Information System (INIS)

    This paper is concerned with the use of the nonlocal Timoshenko beam model for free vibration analysis of single-walled carbon nanotubes (CNTs) including the thermal effect. Unlike the Euler beam model, the Timoshenko beam model allows for the effects of transverse shear deformation and rotary inertia. These effects become significant for CNTs with small length-to-diameter ratios that are normally encountered in applications such as nanoprobes. The elastic Timoshenko beam model is reformulated using the nonlocal differential constitutive relations of Eringen (1972 Int. J. Eng. Sci. 10 1-16). The study focuses on the wave dispersion caused not only by the rotary inertia and the shear deformation in the traditional Timoshenko beam model but also by the nonlocal elasticity characterizing the microstructure of CNTs in a wide frequency range up to terahertz. Numerical results are presented using the nonlocal beam theory to bring out the effect of both the nonlocal parameter and the temperature change on the properties of transverse vibrations of CNTs. The exact nonlocal Timoshenko beam solution presented here should be useful to engineers who are designing microelectromechanical and nanoelectromechanical devices.

  12. The thermal effect on vibration of single-walled carbon nanotubes using nonlocal Timoshenko beam theory

    Energy Technology Data Exchange (ETDEWEB)

    Benzair, A; Tounsi, A; Besseghier, A [Laboratoire des Materiaux et Hydrologie, Universite de Sidi Bel Abbes, BP 89 Cite Ben M' hidi, 22000 Sidi Bel Abbes (Algeria); Heireche, H; Moulay, N; Boumia, L [Universite de Sidi Bel Abbes, Departement de Physique, BP 89 Cite Ben M ' hidi, 22000 Sidi Bel Abbes (Algeria)], E-mail: tou_abdel@yahoo.com

    2008-11-21

    This paper is concerned with the use of the nonlocal Timoshenko beam model for free vibration analysis of single-walled carbon nanotubes (CNTs) including the thermal effect. Unlike the Euler beam model, the Timoshenko beam model allows for the effects of transverse shear deformation and rotary inertia. These effects become significant for CNTs with small length-to-diameter ratios that are normally encountered in applications such as nanoprobes. The elastic Timoshenko beam model is reformulated using the nonlocal differential constitutive relations of Eringen (1972 Int. J. Eng. Sci. 10 1-16). The study focuses on the wave dispersion caused not only by the rotary inertia and the shear deformation in the traditional Timoshenko beam model but also by the nonlocal elasticity characterizing the microstructure of CNTs in a wide frequency range up to terahertz. Numerical results are presented using the nonlocal beam theory to bring out the effect of both the nonlocal parameter and the temperature change on the properties of transverse vibrations of CNTs. The exact nonlocal Timoshenko beam solution presented here should be useful to engineers who are designing microelectromechanical and nanoelectromechanical devices.

  13. Nanoscale Soldering of Positioned Carbon Nanotubes using Highly Conductive Electron Beam Induced Gold Deposition

    DEFF Research Database (Denmark)

    Madsen, Dorte Nørgaard; Mølhave, Kristian; Mateiu, Ramona Valentina; Bøggild, Peter; Rasmussen, A.M.; Appel, C.C.; Brorson, M; Jacobsen, C.J.H.

    2003-01-01

    We have developed an in-situ method for controlled positioning of carbon nanotubes followed by highly conductive contacting of the nanotubes, using electron beam assisted deposition of gold. The positioning and soldering process takes place inside an Environmental Scanning Electron Microscope (E...... embedded in a carbon matrix. Nanoscale soldering of multi-walled carbon nanotubes (MWNT) onto microelectrodes was achieved by deposition of a conducting gold line across a contact point between nanotube and electrode. The solderings were found to be mechanically stronger than the carbon nanotubes. We have......-SEM) in the presence of a source of gold-organic precursor gas. Bridges deposited between suspended microelectrodes show resistivities down to 10-4 Ωcm and Transmission Electron Microscopy (TEM) of the deposits reveals a dense core of gold particles surrounded by a crust of small gold nanoparticles...

  14. Carbon ion beam focusing using laser irradiated heated diamond hemispherical shells

    Energy Technology Data Exchange (ETDEWEB)

    Offermann, Dustin T [Los Alamos National Laboratory; Flippo, Kirk A [Los Alamos National Laboratory; Gaillard, Sandrine A [Los Alamos National Laboratory

    2009-01-01

    Experiments preformed at the Los Alamos National Laboratory's Trident Laser Facility were conducted to observe the acceleration and focusing of carbon ions via the TNSA mechanism using hemispherical diamond targets. Trident is a 200TW class laser system with 80J of 1 {micro}m, short-pulse light delivered in 0.5ps, with a peak intensity of 5 x 10{sup 20} W/cm{sup 2}. Targets where Chemical Vapor Deposition (CVD) diamonds formed into hemispheres with a radius of curvature of 400{micro}m and a thickness of 5{micro}m. The accelerated ions from the hemisphere were diagnosed by imaging the shadow of a witness copper mesh grid located 2mm behind the target onto a film pack located 5cm behind the target. Ray tracing was used to determine the location of the ion focal spot. The TNSA mechanism favorably accelerates hydrogen found in and on the targets. To make the carbon beam detectable, targets were first heated to several hundred degrees Celsius using a CW, 532nm, 8W laser. Imaging of the carbon beam was accomplished via an auto-radiograph of a nuclear activated lithium fluoride window in the first layer of the film pack. The focus of the carbon ion beam was determined to be located 630 {+-} 110 {micro}m from the vertex of the hemisphere.

  15. Electron beam processing of carbon fibre reinforced braided composites

    International Nuclear Information System (INIS)

    The possibility of producing a new type carbon fibre reinforced composite profile has been examined by applying braiding, a well-known process of textile technology. Pipe and hollow profile composite products can be manufactured this way by applying Electron Beam curing. The fabric-like braided reinforcing structure was manufactured out of Hungarian-made carbon fibre roving of 48,000 elementary fibres. The mutual irradiation of the system impregnated with epoxy-acrylate oligomer by 8 MeV EB resulted in better mechanical properties then conventional chemical curing. Owing to its low density and high specific strength this new composite product can possibly be applied in dynamically loaded structures e.g. in the automotive industry

  16. Carbon doping in molecular beam epitaxy of GaAs from a heated graphite filament

    Science.gov (United States)

    Malik, R. J.; Nottenberg, R. N.; Schubert, E. F.; Walker, J. F.; Ryan, R. W.

    1988-01-01

    Carbon doping of GaAs grown by molecular beam epitaxy has been obtained for the first time by use of a heated graphite filament. Controlled carbon acceptor concentrations over the range of 10 to the 17th-10 to the 20th/cu cm were achieved by resistively heating a graphite filament with a direct current power supply. Capacitance-voltage, p/n junction and secondary-ion mass spectrometry measurements indicate that there is negligible diffusion of carbon during growth and with postgrowth rapid thermal annealing. Carbon was used for p-type doping in the base of Npn AlGaAs/GaAs heterojunction bipolar transistors. Current gains greater than 100 and near-ideal emitter heterojunctions were obtained in transistors with a carbon base doping of 1 x 10 to the 19th/cu cm. These preliminary results indicate that carbon doping from a solid graphite source may be an attractive substitute for beryllium, which is known to have a relatively high diffusion coefficient in GaAs.

  17. Electron beam influence on the carbon contamination of electron irradiated hydroxyapatite thin films

    Energy Technology Data Exchange (ETDEWEB)

    Hristu, Radu; Stanciu, Stefan G.; Tranca, Denis E.; Stanciu, George A., E-mail: stanciu@physics.pub.ro

    2015-08-15

    Highlights: • Carbon contamination mechanisms of electron-beam-irradiated hydroxyapatite. • Atomic force microscopy phase imaging used to detect carbon contamination. • Carbon contamination dependence on electron energy, irradiation time, beam current. • Simulation of backscattered electrons confirms the experimental results. - Abstract: Electron beam irradiation which is considered a reliable method for tailoring the surface charge of hydroxyapatite is hindered by carbon contamination. Separating the effects of the carbon contamination from those of irradiation-induced trapped charge is important for a wide range of biological applications. In this work we focus on the understanding of the electron-beam-induced carbon contamination with special emphasis on the influence of the electron irradiation parameters on this phenomenon. Phase imaging in atomic force microscopy is used to evaluate the influence of electron energy, beam current and irradiation time on the shape and size of the resulted contamination patterns. Different processes involved in the carbon contamination of hydroxyapatite are discussed.

  18. Electron beam influence on the carbon contamination of electron irradiated hydroxyapatite thin films

    International Nuclear Information System (INIS)

    Highlights: • Carbon contamination mechanisms of electron-beam-irradiated hydroxyapatite. • Atomic force microscopy phase imaging used to detect carbon contamination. • Carbon contamination dependence on electron energy, irradiation time, beam current. • Simulation of backscattered electrons confirms the experimental results. - Abstract: Electron beam irradiation which is considered a reliable method for tailoring the surface charge of hydroxyapatite is hindered by carbon contamination. Separating the effects of the carbon contamination from those of irradiation-induced trapped charge is important for a wide range of biological applications. In this work we focus on the understanding of the electron-beam-induced carbon contamination with special emphasis on the influence of the electron irradiation parameters on this phenomenon. Phase imaging in atomic force microscopy is used to evaluate the influence of electron energy, beam current and irradiation time on the shape and size of the resulted contamination patterns. Different processes involved in the carbon contamination of hydroxyapatite are discussed

  19. Dual ion beam deposition of carbon films with diamondlike properties

    Science.gov (United States)

    Mirtich, M. J.; Swec, D. M.; Angus, J. C.

    1984-01-01

    A single and dual ion beam system was used to generate amorphous carbon films with diamond like properties. A methane/argon mixture at a molar ratio of 0.28 was ionized in the low pressure discharge chamber of a 30-cm-diameter ion source. A second ion source, 8 cm in diameter was used to direct a beam of 600 eV Argon ions on the substrates (fused silica or silicon) while the deposition from the 30-cm ion source was taking place. Nuclear reaction and combustion analysis indicate H/C ratios for the films to be 1.00. This high value of H/C, it is felt, allowed the films to have good transmittance. The films were impervious to reagents which dissolve graphitic and polymeric carbon structures. Although the measured density of the films was approximately 1.8 gm/cu cm, a value lower than diamond, the films exhibited other properties that were relatively close to diamond. These films were compared with diamondlike films generated by sputtering a graphite target.

  20. Blister formation on tungsten surface by irradiating hydrogen and carbon mixed ion beam

    International Nuclear Information System (INIS)

    A mixed carbon and hydrogen beam was irradiated on to tungsten materials. In the case in which the carbon concentration and sample temperature were 0.95% and 653 K, respectively, large numbers and blisters of various sizes were formed. But in a low carbon concentration or high temperature case, no significant blisters were formed. It was found that carbon impurities in the beam play an important role in blister formation. (author)

  1. Experiments with the newly available carbon beams at ISOLDE

    CERN Multimedia

    Garcia borge, M J; Koester, U H; Koldste, G T

    2002-01-01

    Recent target-ions-source developments at ISOLDE providing significantly increased yields for carbon isotopes, open up for new and intriguing experiments. We propose to exploit this in two different ways. In particular we wish to do an elastic resonance scattering experiment of $^{9}$C on a proton target to gain information on the particle unbound system $^{10}$N. Furthermore we wish to perform decay experiments of the neutron-rich carbon isotopes, with special focus on $^{17-19}$C but also including a test to see whether the even more neutron-rich isotopes $^{20,22}$C are accessible at ISOLDE.

  2. Beam test of compact ECR ion source for carbon therapy

    International Nuclear Information System (INIS)

    Ion source for medical facilities should have characteristics of easy maintenance, low electric power, good stability and long operation time without maintenance (one year or more). Based on the proto type compact source, a 10 GHz compact ECR ion source with all permanent magnets has been developed. Peaks of the mirror magnetic field along the beam axis are 0.59 T at the extraction side and 0.87 T at the gas injection side, respectively, while the minimum B strength is 0.25 T. The source has a diameter of 320 mm and a length of 295 mm. The result of beam tests shows that a C4+ intensity of 530 μA was obtained under an extraction voltage of 45 kV. This paper describes the design detail and the experimental results for the new source. (author)

  3. Kinetics of ion beam deposition of carbon at room temperature

    International Nuclear Information System (INIS)

    Growth rates of carbon films grown by ion beam deposition using methane gas were measured in situ as a function of deposition conditions. The methane pressure dependence of the growth rate was used to measure the cross-section for charge exchange. Variations in deposition rate per incident energetic particle found for each ion energy were related to ion current density. It was found that rates of growth per incident energetic specie were (i) largest for the smallest current densities, (ii) decreased monotonically with increasing current density, and (iii) were consistently larger than can be explained by deposition directly from the energetic flux alone. These observations were interpreted in terms of irradiation-induced surface interactions which promote chemisorption of methane physisorbed from the ambient atmosphere. (orig.)

  4. A simulation study of a C-shaped in-beam PET system for dose verification in carbon ion therapy

    International Nuclear Information System (INIS)

    The application of hadrons such as carbon ions is being developed for the treatment of cancer. The effectiveness of such a technique is due to the eligibility of charged particles in delivering most of their energy near the end of the range, called the Bragg peak. However, accurate verification of dose delivery is required since misalignment of the hadron beam can cause serious damage to normal tissue. PET scanners can be utilized to track the carbon beam to the tumor by imaging the trail of the hadron-induced positron emitters in the irradiated volume. In this study, we designed and evaluated (through Monte Carlo simulations) an in-beam PET scanner for monitoring patient dose in carbon beam therapy. A C-shaped PET and a partial-ring PET were designed to avoid interference between the PET detectors and the therapeutic carbon beam delivery. Their performance was compared with that of a full-ring PET scanner. The C-shaped, partial-ring, and full-ring scanners consisted of 14, 12, and 16 detector modules, respectively, with a 30.2 cm inner diameter for brain imaging. Each detector module was composed of a 13×13 array of 4.0 mm×4.0 mm×20.0 mm LYSO crystals and four round 25.4 mm diameter PMTs. To estimate the production yield of positron emitters such as 10C, 11C, and 15O, a cylindrical PMMA phantom (diameter, 20 cm; thickness, 20 cm) was irradiated with 170, 290, and 350 AMeV 12C beams using the GATE code. Phantom images of the three types of scanner were evaluated by comparing the longitudinal profile of the positron emitters, measured along the carbon beam as it passed a simulated positron emitter distribution. The results demonstrated that the development of a C-shaped PET scanner to characterize carbon dose distribution for therapy planning is feasible.

  5. In silico carbon molecular beam epitaxial growth of graphene on the h-BN substrate: carbon source effect on van der Waals epitaxy

    Science.gov (United States)

    Lee, Jonghoon; Varshney, Vikas; Park, Jeongho; Farmer, Barry L.; Roy, Ajit K.

    2016-05-01

    during the initial phase of graphene growth simulation using a carbon trimer beam is captured. An initially sp hybridized carbon atom (red colored) becomes sp2 hybridized as a result of additional covalent bonding with the impinging carbon trimer. As the bond angle around the red carbon changes from 180 degree (sp) to 120 degree (sp2), nearby carbon atoms enclose to form a hexagon structure composed of 6 carbon atoms. See DOI: 10.1039/c6nr01396a

  6. Beam-dump/diagnostics box for a 10-kA 50-MeV, 50-ns electron beam

    International Nuclear Information System (INIS)

    We have developed a dump for the ATA beam that consists of a series of carbon plates whose collective thickness totals approximately 1.5 ranges at 50 MeV. The energy dissipated in the plates is radiated to a water-cooled wall. The dump is designed to dissipate up to 175 kW of average power. A small hole along the axis of the plates forms a beamlet that passes through an energy analyzer. The analyzer consists of a 600 bending magnet and two high-sensitivity beam-current/position monitors. The ratio of the beamlet current to full current is used to estimate the beam emittance

  7. Deflection of carbon dioxide laser and helium-neon laser beams in a long-pulse relativistic electron beam diode

    International Nuclear Information System (INIS)

    Deflection of carbon dioxide and helium-neon laser beams has been used to measure plasma and neutral density gradients during the operating mode and after the shorting time of a long-pulse field-emission electron beam diode. Plasma density gradients of (1014--1015) cm-4 were observed throughout the diode during the final microsecond of the 2--3 μs electron beam pulse. The neutral density gradient was less than 1x1018 cm-4 during the electron beam pulse. Upon diode shorting, neutral density gradients increased to (1018--1019) cm-4 over ∼1 μs, and decayed over many microseconds. Plasma density gradients of ∼1015 cm-4 were also observed after shorting. These experiments demonstrate the value of carbon-dioxide laser and helium-neon laser deflection for diagnosing plasma and neutral particles in long-pulse electron beam diodes

  8. The proliferative response of mouse intestinal crypts during fractionated irradiation of carbon beams

    International Nuclear Information System (INIS)

    Clonogenic assay of jejunal crypt during carbon beam and X-ray irradiations was performed. Fractionation with top-up dose assay revealed carbon beam irradiations caused more damage than X-ray did. To clarify this problem is urgent. (author)

  9. Enhancement of neutral beam deposition in hydrogen discharge using carbon pellet injection in LHD

    International Nuclear Information System (INIS)

    The central ion temperature in the large helical device (LHD), as measured by charge-exchange recombination spectroscopy, has been improved to a record 5.6 keV by combining 21 MW of neutral beam heating with the injection of a carbon pellet. The intensity of the neutral beam emission of the hydrogen Balmer line (Hα: n=3 → 2) was observed to weaken along the beam injection axis following the carbon pellet injection due to the increased beam attenuation. The beam-emission intensity was reconstructed by calculating the density distribution, and the beam-stopping coefficients, along a beam injection axis and was found to fit well to the measured beam-emission for a mixed hydrogen and carbon target plasma. The dynamics of the neutral beam deposition power and the carbon fraction were estimated from the beam-emission measurements using data from ADAS. We conclude that the beam deposition power in a carbon pellet discharge is enhanced over that of a pure hydrogen discharge. (author)

  10. The expert system OPTRAN (Ver 1.0) and its application to beam transportation line design

    International Nuclear Information System (INIS)

    The expert system OPTRAN (Ver 1.0) used for beam transportation line design is introduced. The knowledge storage and reasoning principle, of which the intelligence part of OPTRAN are composed, have been described in detail. By using OPTRAN (Ver 1.0), the design of a beam transportation line for extracted ion beam of Cyclone 30 was completed

  11. Biological intercomparison using gut crypt survivals for proton and carbon-ion beams

    International Nuclear Information System (INIS)

    Charged particle therapy depends on biological information for the dose prescription. Relative biological effectiveness or RBE for this requirement could basically be provided by experimental data. As RBE values of protons and carbon ions depend on several factors such as cell/tissue type, biological endpoint, dose and fractionation schedule, a single RBE value could not deal with all different radiosensitivities. However, any biological model with accurate reproducibility is useful for comparing biological effectiveness between different facilities. We used mouse gut crypt survivals as endpoint, and compared the cell killing efficiency of proton beams at three Japanese facilities. Three Linac X-ray machines with 4 and 6 MeV were used as reference beams, and there was only a small variation (coefficient of variance<2%) in biological effectiveness among them. The RBE values of protons relative to Linac X-rays ranged from 1.0 to 1.11 at the middle of a 6-cm SOBP (spread-out Bragg peak) and from 0.96 to 1.01 at the entrance plateau. The coefficient of variance for protons ranged between 4.0 and 5.1%. The biological comparison of carbon ions showed fairly good agreement in that the difference in biological effectiveness between National Institute of Radiological Sciences (NIRS)/ Heavy Ion Medical Accelerator in Chiba (HIMAC) and Gesellschaft fur Schwerionenforschung (GSI)/Heavy Ion Synchrotron (SIS) was 1% for three positions within the 6-cm SOBP. The coefficient of variance was <1.7, <0.6 and <1.6% for proximal, middle and distal SOBP, respectively. We conclude that the inter-institutional variation of biological effectiveness is smaller for carbon ions than protons, and that beam-spreading methods of carbon ions do not critically influence gut crypt survival. (author)

  12. Carbon-ion beam irradiation kills X-ray-resistant p53-null cancer cells by inducing mitotic catastrophe.

    Directory of Open Access Journals (Sweden)

    Napapat Amornwichet

    Full Text Available BACKGROUND AND PURPOSE: To understand the mechanisms involved in the strong killing effect of carbon-ion beam irradiation on cancer cells with TP53 tumor suppressor gene deficiencies. MATERIALS AND METHODS: DNA damage responses after carbon-ion beam or X-ray irradiation in isogenic HCT116 colorectal cancer cell lines with and without TP53 (p53+/+ and p53-/-, respectively were analyzed as follows: cell survival by clonogenic assay, cell death modes by morphologic observation of DAPI-stained nuclei, DNA double-strand breaks (DSBs by immunostaining of phosphorylated H2AX (γH2AX, and cell cycle by flow cytometry and immunostaining of Ser10-phosphorylated histone H3. RESULTS: The p53-/- cells were more resistant than the p53+/+ cells to X-ray irradiation, while the sensitivities of the p53+/+ and p53-/- cells to carbon-ion beam irradiation were comparable. X-ray and carbon-ion beam irradiations predominantly induced apoptosis of the p53+/+ cells but not the p53-/- cells. In the p53-/- cells, carbon-ion beam irradiation, but not X-ray irradiation, markedly induced mitotic catastrophe that was associated with premature mitotic entry with harboring long-retained DSBs at 24 h post-irradiation. CONCLUSIONS: Efficient induction of mitotic catastrophe in apoptosis-resistant p53-deficient cells implies a strong cancer cell-killing effect of carbon-ion beam irradiation that is independent of the p53 status, suggesting its biological advantage over X-ray treatment.

  13. Radiation biophysical studies with mammalian cells and a modulated carbon ion beam

    International Nuclear Information System (INIS)

    Chinese hamster (V-79) and human kidney (T-1) cells were irradiated in stirred suspensions placed at various positions in the plateau and extended Bragg peak of a 400-MeV/amu carbon ion beam. The range of the ions was modulated by a lead (translational) ridge filter and a brass (spiral) ridge filter designed to produce extended peaks of approximately 4 and 10 cm, respectively. Stationary-phase and G1-phase populations of Chinese hamster cells were found to have different absolute radiosensitivities which, in turn, were different from that of asynchronous human kidney cells. The increase in relative biological effectiveness (RBE) observed as carbon ions were slowed down and stopped in water was similar for the three cell populations at doses greater than 400 rad. At lower doses the RBE was greater for the hamster cell populations than for the human kidney cells. The gain in RBE (at the 50% survival level) between the plateaus and the middle region of the extended peaks was approximately 2.0 and 1.7 for the 4- and 10-cm extended peaks, respectively. Oxygen enhancement ratios (OER) were determined at the 10% survival levels with stationary-phase populations of hamster cells. Values of 2.8, 2.65, and 1.65 were obtained for the OER of 220-kV x rays, plateau carbon, and the middle region of the 4-cm carbon peak, respectively. Across the 10-cm carbon peak the OER was found to vary between values of 2.4 to 1.55 from the proximal to distal positions

  14. Primary result of application of carbon ion beam and gamma ray for rice breeding improvement

    International Nuclear Information System (INIS)

    Recently, Carbon ion beam have been recently attracted as mutagens. A characteristic feature of ion beams is their ability to deposit high energy on a target, densely and locally, as opposed to low linear energy transfer radiation such as gamma rays and X rays. In Vietnam, application of carbon ion beam just starting through cooperation FNCA between Japan and ASEAN countries from 2009. In this report, we want to report primary result of application carbon ion beam and gamma ray for rice breeding improvement of Khang dan 18. Through primary experimental for optimum dose for carbon ion beam we found that the dose of 40 and 60 Gy was suitable for Khang dan variety treatment. Based on optimum dose 40 and 60 Gy of carbon ion beam and 150 and 200 Gy of gamma ray we irradiated for Khang dan variety. The higher dose, the lower seed set ratio were determined both ion beam and gamma ray. Especial in carbon ion beam experiment at the dose of 60 Gy was 39.18% in small experiment and more than 20% seed set ratio at the real experiment. At M4 generation, in the experiment with carbon ion beam at the dose of 60 Gy we received mutant which increase the weight of 1000 seeds (23.0 g) compare to the control 19.7 g meanwhile experiment with gamma ray at the dose of 200 Gy we received some mutant not much change in the seed weight. This may show that carbon ion beam more effective than gamma ray in term of change some characteristics of rice. (author)

  15. Beam dump for 10 kW 10 Mev LINAC

    International Nuclear Information System (INIS)

    Raja Ramanna Centre for Advanced Technology has developed a 10 kW, 10 MeV linear particle accelerator (LINAC) for the Agricultural Radiation Processing Facility for radiation processing of agricultural products and medical sterilization. This paper presents an improved design for the existing beam dump of this accelerator. The new design is more efficient, safer, economical and compact than the previous design [1]. The new design is investigated both for maximum stress and maximum temperature. The material selection is done keeping in mind the radiation damage, thermal conductivity, corrosion in the ozone environment, mechanical strength and manufacturability. The estimated maximum temperature is 85.8 °C which is less than the boiling point of water at 1 bar pressure (100 °C). The maximum stress intensity is estimated to be 42.60 N/mm2 which is less than the yield strength of the material [2]. - Highlights: • RRCAT has developed 10 kW 10 MeV LINAC for radiation processing of agricultural products and medical sterilization. • An improved design for the beam dump is presented which is more efficient, economical and compact than the previous design. • Low conductivity water is pumped through the channels to remove most of the heat by forced convection. • The low conductivity water is supplied at high pressures ∼6 bars, making the structure prone to deflections. • The estimated maximum temperature and the maximum stress intensity are within the acceptable limits

  16. Analysis of mutagenic effects induced by carbon beams at different LET in a red yeast strain

    International Nuclear Information System (INIS)

    To evaluate inactive and mutagenic effects of carbon beam at different LET, the inactivation cross section and mutation cross section induced by carbon beams of different LET values were investigated in a red yeast strain Rhodotorula glutinis AY 91015. It was found that the maximum inactivation cross section of 4.37μm2, which was very close to the average nucleus cross section, was at LET of 120.0 keV/μm. The maximum mutation cross section was at LET of 96.0 keV/μm. Meanwhile, the highest mutagenicity of carbon ion was found around 58.2 keV/μm. It implied that the most efficient LET to induce mutation in survival yeasts was 58.2 keV/μm, which corresponded to energy of 35 MeV/u carbon beam. The most effective carbon beam to induce inactivation and mutation located at different energy region. (authors)

  17. A method of beam control for NFZ-10 industrial irradiation linac

    International Nuclear Information System (INIS)

    Traditionally negative feedback coming from output beam is used to stabilize output beam by regulating filament voltage of bombarding diode electron gun. The authors analysed the shortcomings of the method in detail and put forward a new method of regulating bombarding high voltage in NFZ-10 industrial irradiation linac. Output beam with high stability and high accuracy was obtained

  18. Ion beam deposition of amorphous carbon films with diamond like properties

    Science.gov (United States)

    Angus, John C.; Mirtich, Michael J.; Wintucky, Edwin G.

    1982-01-01

    Carbon films were deposited on silicon, quartz, and potassium bromide substrates from an ion beam. Growth rates were approximately 0.3 micron/hour. The films were featureless and amorphous and contained only carbon and hydrogen in significant amounts. The density and carbon/hydrogen ratio indicate the film is a hydrogen deficient polymer. One possible structure, consistent with the data, is a random network of methylene linkages and tetrahedrally coordinated carbon atoms.

  19. A secondary emission type beam profile monitor with carbon graphite ribbons

    International Nuclear Information System (INIS)

    We developed a secondary emission type beam profile monitor with carbon graphite ribbons as a beam target. The carbon graphite is excellent in endurance against heat load, and that they are thin as 1.6-3.0 micron and low z (=6) are advantage for reducing beam loss. Furthermore, since ribbons emits larger amount of electrons than ordinal metal wires because of larger surface, the monitor has higher sensitivity. The monitors were installed in the end of 3-50 BT and injection point of MR in J-PARC, in order to measure injection beam profiles by single passing. Normal size target has 32ch ribbons with 2 or 3 mm in width and their length is 200 mm each. In this paper, basic characteristics of the carbon graphite target and results of beam measurement are reported. (author)

  20. Beam trial and operation optimization of 10 MeV industrial electron Linac

    International Nuclear Information System (INIS)

    A 10 MeV travelling wave industrial (TWINDUS) electron linac suitable for radiation processing applications is under development at RRCAT. The linac is designed and developed indigenously to deliver beam power of 6 kW at energy level of 10 MeV. It consists of various subsystems such as accelerating structure, electron gun, microwave system, control system, beam injection and focusing system, vacuum system, beam diagnostic and measurement system and safety system. After independent subsystem level testing, all the systems were integrated and beam trial experiments were taken up in a shielded vault after obtaining due approval from Atomic Energy Regulatory Board (AERB). Optimization and harmonization of the operating parameters of all these sub-systems is carried-out in order to achieve the desired electron beam current and power. This paper describes the results of series of beam trial experiments carried out to optimize operation parameters for demonstrating operation at 4.2 kW beam power

  1. Production of a sub-10 fs electron beam with 107 electrons

    Science.gov (United States)

    Han, Jang-Hui

    2011-05-01

    We study the possibility to produce a 1.6 pC electron beam (107 electrons) with a bunch length of less than 10 fs and a beam energy of a few MeV. Such a short, relativistic beam will be useful for an electron diffraction experiment with a 10 fs time resolution. An electron beam with 107 electrons will allow a single-shot experiment with a laser pulse pump and an electron beam probe. In this design, an S-band photocathode gun is used for generating and accelerating a beam and a buncher consisting of two S-band four-cell cavities is used for temporally compressing the beam. Focusing solenoids control the beam transverse divergence and size at the sample. Numerical optimization is carried out to achieve a beam with a 4 fs full-width-at-half-maximum length, a 26 microradian root-mean-square divergence, and a 2 nm transverse coherence length at a 3.24 MeV beam energy. When state-of-the-art rf stability is considered, beam arrival time jitter at the sample is calculated to be about 10 fs.

  2. Emulsion Cloud Chamber technique to measure the fragmentation of a high-energy carbon beam

    OpenAIRE

    De Lellis, G.; Buontempo., S; Di Capua, F.; Marotta, A; Migliozzi, P.; Petukhov, Y.; Pistillo, C; Russo, A; Lavina, L. Scotto; Strolin, P.(Dipartimento di Fisica dell’Università Federico II di Napoli, 80125 , Naples, Italy); Tioukov, V.; Ariga, A.(Albert Einstein Center for Fundamental Physics, Laboratory for High Energy Physics (LHEP), University of Bern, CH-3012, Bern, Switzerland); Naganawa, N.; Toshito, T.; Furusawa, Y.

    2007-01-01

    Beams of Carbon nuclei are used or planned to be used in various centers for cancer treatment around the world because of their therapeutic advantages over proton beams. The knowledge of the fragmentation of Carbon nuclei when they interact with the human body is important to evaluate the spatial profile of their energy deposition in the tissues, hence the damage to the tissues neighboring the tumor. In this respect, the identification of the fragmentation products is a key element. We presen...

  3. Electron Cloud in Steel Beam Pipe vs Titanium Nitride Coated and Amorphous Carbon Coated Beam Pipes in Fermilab's Main Injector

    Energy Technology Data Exchange (ETDEWEB)

    Backfish, Michael

    2013-04-01

    This paper documents the use of four retarding field analyzers (RFAs) to measure electron cloud signals created in Fermilab’s Main Injector during 120 GeV operations. The first data set was taken from September 11, 2009 to July 4, 2010. This data set is used to compare two different types of beam pipe that were installed in the accelerator. Two RFAs were installed in a normal steel beam pipe like the rest of the Main Injector while another two were installed in a one meter section of beam pipe that was coated on the inside with titanium nitride (TiN). A second data run started on August 23, 2010 and ended on January 10, 2011 when Main Injector beam intensities were reduced thus eliminating the electron cloud. This second run uses the same RFA setup but the TiN coated beam pipe was replaced by a one meter section coated with amorphous carbon (aC). This section of beam pipe was provided by CERN in an effort to better understand how an aC coating will perform over time in an accelerator. The research consists of three basic parts: (a) continuously monitoring the conditioning of the three different types of beam pipe over both time and absorbed electrons (b) measurement of the characteristics of the surrounding magnetic fields in the Main Injector in order to better relate actual data observed in the Main Injector with that of simulations (c) measurement of the energy spectrum of the electron cloud signals using retarding field analyzers in all three types of beam pipe.

  4. Multi-pulsed intense electron beam emission from velvet, carbon fibers, carbon nano-tubes and dispenser cathodes

    Science.gov (United States)

    Xia, Lian-Sheng; Yang, An-Min; Chen, Yi; Zhang, Huang; Liu, Xing-Guang; Li, Jin; Jiang, Xiao-Guo; Zhang, Kai-Zhi; Shi, Jin-Shui; Deng, Jian-Jun; Zhang, Lin-Wen

    2010-11-01

    The experimental results of studies of four kinds of cathode emitting intense electron beams are demonstrated under multi-pulsed mode based on an experimental setup including two multi-pulse high voltage sources. The tested cathodes include velvet, carbon fibers, carbon nano-tubes (CNTs) and dispenser cathodes. The results indicate that all four are able to emit multi-pulsed beams. For velvet, carbon fiber and CNTs, the electron induced cathode plasma emission may be the main process and this means that there are differences in beam parameters from pulse to pulse. For dispenser cathodes tested in the experiment, although there is a little difference from pulse to pulse for some reason, thermal-electric field emission may be the main process.

  5. Multi-pulsed intense electron beam emission from velvet, carbon fibers, carbon nano-tubes and dispenser cathodes

    International Nuclear Information System (INIS)

    The experimental results of studies of four kinds of cathode emitting intense electron beams are demonstrated under multi-pulsed mode based on an experimental setup including two multi-pulse high voltage sources. The tested cathodes include velvet, carbon fibers, carbon nano-tubes (CNTs) and dispenser cathodes. The results indicate that all four are able to emit multi-pulsed beams. For velvet, carbon fiber and CNTs, the electron induced cathode plasma emission may be the main process and this means that there are differences in beam parameters from pulse to pulse. For dispenser cathodes tested in the experiment, although there is a little difference from pulse to pulse for some reason, thermal-electric field emission may be the main process. (authors)

  6. Numerical simulation of polarization beam splitter with triangular lattice of multi-walled carbon nanotube arrays

    Science.gov (United States)

    Wu, Xingxing; Yun, Maojin; Wang, Mei; Liu, Chao; Li, Kai; Qin, Xiheng; Kong, Weijin; Dong, Lifeng

    2015-12-01

    A kind of polarization beam splitter with triangular lattice of multi-walled carbon nanotube arrays is designed and simulated. In the employed structure transverse-electric (TE) light is confined in the line defect with photonic band gap effect, while transverse-magnetic (TM) light is guided through it with extremely low diffraction. The performance of the designed polarization beam splitter is evaluated by utilizing optical properties of multi-walled carbon nanotubes, finite element modeling of wave propagation and transmission through periodic arrays. Simulation results indicate that the designed polarization beam splitter has low loss and less cross talk, and thereby may have practical applications in the integrated optical field.

  7. Bending of metal-filled carbon nanotube under electron beam irradiation

    Directory of Open Access Journals (Sweden)

    Abha Misra

    2012-03-01

    Full Text Available Electron beam irradiation induced, bending of Iron filled, multiwalled carbon nanotubes is reported. Bending of both the carbon nanotube and the Iron contained within the core was achieved using two approaches with the aid of a high resolution electron microscope (HRTEM. In the first approach, bending of the nanotube structure results in response to the irradiation of a pristine kink defect site, while in the second approach, disordered sites induce bending by focusing the electron beam on the graphite walls. The HRTEM based in situ observations demonstrate the potential for using electron beam irradiation to investigate and manipulate the physical properties of confined nanoscale structures.

  8. Numerical Investigation Of The Bombardment Of A Graphene Sheet By A Beam Of Carbon Atoms

    Directory of Open Access Journals (Sweden)

    O.V. Khomenko

    2009-01-01

    Full Text Available Classical molecular dynamics simulations of the bombardment of a graphene sheet by a beam of carbon atoms are carried out. Covalent bonds in the irradiated sample are described by the Brenner potential. The approximation of elastic balls interacting with graphene via the Lennard-Jones potential is used for particles in a beam. The influence of the energy and density of irradiating carbon atoms and of the presence of a thermostat on physical processes occurring during the collisions with the sample is investigated. Energy values of the particles in a beam, which are enough for the sample destruction, are defined.

  9. Using Pyrolysis Molecular Beam Mass Spectrometry to Characterize Soil Organic Carbon in Native Prairie Soils

    Science.gov (United States)

    The objective of this study was to characterize soil organic carbon (SOC) with pyrolysis molecular beam mass spectrometry (py-MBMS) and then to determine correlations between the mass spectra and associated soil characterization data. Both soil carbon chemistry and the organic forms in which SOC is...

  10. Enhancement of Charpy impact value by electron beam irradiation of carbon fiber reinforced polymer

    International Nuclear Information System (INIS)

    Influences of electron beam irradiation on Charpy impact value of carbon fiber reinforced polymer (CFRP) have been investigated. The irradiation, which is one of short-time treatments, enhanced the Charpy impact value of CFRP. Furthermore, strengthening of carbon fiber, ductility enhancement of polymer and interface effects on impact test explains the impact value enhancement of CFRP. (author)

  11. Shear strengthening of pre-damaged reinforced concrete beams with carbon fiber reinforced polymer sheet strips

    Institute of Scientific and Technical Information of China (English)

    Feras ALZOUBI; ZHANG Qi; LI Zheng-liang

    2007-01-01

    This paper presents the results of an experimental investigation on the response of pre-damaged reinforced concrete (RC) beam strengthened in shear using applied-epoxy unidirectional carbon fiber reinforced polymer (CFRP) sheet. The reasearch included four test rectangular simply supported RC beams in shear capacity. One is the control beam, two RC beams are damaged to a predetermined degree from ultimate shear capacity of the control beam, and the last beam is left without pre-damaged and then strengthened with using externally bonded carbon fiber reinforced polymer to upgrade their shear capacity. We focused on the damage degree to beams during strengthening, therefore, only the beams with side-bonded CFRPs strips and horizontal anchored strips were used. The results show the feasibility of using CFRPs to restore or increase the load-carrying capacity in the shear of damaged RC beams. The failure mode of all the CFRP-strengthened beams is debonding of CFRP vertical strips. Two prediction available models in ACI-440 and fib European code were compared with the experimental results.

  12. The effect of Ar neutral beam treatment of screen-printed carbon nanotubes for enhanced field emission

    International Nuclear Information System (INIS)

    This study examined the effectiveness of an Ar neutral beam as a surface treatment for improving the field emission properties of screen-printed carbon nanotubes (CNTs). A short period of the neutral beam treatment on tape-activated CNTs enhanced the emission properties of the CNTs, showing a decrease in the turn-on field and an increase in the number of emission sites. The neutral beam treatment appeared to render the CNT surfaces more actively by exposing more CNTs from the CNT paste without cutting or kinking the already exposed long CNT emitters. The treated CNTs emitted more electrons than the CNTs treated using other methods. When the field emission properties were measured after the neutral beam treatment, the turn-on field decreased from 1.65 to 0.60 V/μm and the emission field at 1 mA/cm2 decreased from 3.10 to 2.41 V/μm. After the neutral beam treatment for 10 s, there was an improvement in the stability of the emission current at a constant electric field. It is expected that the neutral beam treatment introduced in this study will provide an easy way of improving the emission intensity and stability of screen-printed CNT emitters

  13. Annual carbon balance of a peatland 10 yr following restoration

    Directory of Open Access Journals (Sweden)

    M. Strack

    2013-05-01

    Full Text Available Undisturbed peatlands represent long-term net sinks of carbon; however, peat extraction converts these systems into large and persistent sources of greenhouse gases. Although rewetting and restoration following peat extraction have taken place over the last several decades, very few studies have investigated the longer term impact of this restoration on peatland carbon balance. We determined the annual carbon balance of a former horticulturally-extracted peatland restored 10 yr prior to the study and compared these values to the carbon balance measured at neighboring unrestored and natural sites. Carbon dioxide (CO2 and methane (CH4 fluxes were measured using the chamber technique biweekly during the growing season from May to October 2010 and three times over the winter period. Dissolved organic carbon (DOC export was measured from remnant ditches in the unrestored and restored sites. During the growing season the restored site had greater uptake of CO2 than the natural site when photon flux density was greater than 1000 μmol m−2 s−1, while the unrestored site remained a source of CO2. Ecosystem respiration was similar between natural and restored sites, which were both significantly lower than the unrestored site. Methane flux remained low at the restored site except from open water pools, created as part of restoration, and remnant ditches. Export of DOC during the growing season was 5.0 and 28.8 g m−2 from the restored and unrestored sites, respectively. Due to dry conditions during the study year all sites acted as net carbon sources with annual balance of the natural, restored and unrestored sites of 250.7, 148.0 and 546.6 g C m−2, respectively. Although hydrological conditions and vegetation community at the restored site remained intermediate between natural and unrestored conditions, peatland restoration resulted in a large reduction in annual carbon loss from the system resulting in a carbon balance more similar to a natural

  14. Stress corrosion cracking tests on electron beam welded carbon steel specimens in carbonate-bicarbonate solution

    International Nuclear Information System (INIS)

    Stress corrosion cracking tests have been performed on tapered carbon steel test pieces containing electron beam welds with a view to defining susceptibility to such cracking in a carbonate-bicarbonate solution at 90 C and an appropriate electrode potential. The tests involved applying cyclic loads to the specimens and it is shown that the threshold stress for cracking reduces linearly with increase in the magnitude of the cyclic load component. Extrapolation of these trends to zero fluctuating stress indicates static load threshold stresses in the vicinity of the yield stress (i.e. about 300 N/mm2 for parent plate without a weld, 400 N/mm2 for specimens with welds on one side only and 600 N/mm2 for specimens having welds penetrating through the thickness of the specimen). The averages of the maximum crack velocities observed were least for parent plate material and greatest for weld metal, the former being essentially intergranular in morphology and the latter mostly transgranular, with heat affected zone material being intermediate between these extremes. (author)

  15. Effect of electron beam irradiation on the properties of carbon fiber

    International Nuclear Information System (INIS)

    Carbon fibers are used as a reinforcement material in an epoxy matrix in advanced composites due to their high mechanical strength, rigidity and low specific density. An important aspect of the mechanical properties of composites is associated to the adhesion between the surface of the carbon fiber and the epoxy matrix. This paper aimed to evaluate the effects of electron beam irradiation on the physicochemical properties of carbon fibers to obtain better adhesion properties in resultant composite. Chemical structure and surface of carbon fiber were determined by FT-IR, elemental analysis and X-ray photoelectron spectroscopy, which indicated that the oxygen content increased significantly with increasing the radiation dose. Thermal stability of the carbon fibers was studied via the thermal gravimetric analysis. Surface morphology of carbon fiber was analyzed by scanning electron microscope. It was found that the degree of surface roughness was increased by electron beam irradiation

  16. Different effects of carbon ion beams and X-rays on clonogenic survival and DNA repair in human pancreatic cancer stem-like cells

    International Nuclear Information System (INIS)

    Purpose: The effects of a carbon ion beam and X-rays on human pancreatic cancer stem-like cells were examined from the point of view of clonogenic survival and DNA repair. Materials and methods: Human pancreatic cancer stem-like cells were treated with and without carbon ion and X-ray irradiation, and then colony, spheroid and tumor formation assays as well as γH2AX foci formation assay were performed. Results: The relative biological effectiveness (RBE) values of a carbon ion beam relative to X-ray for the MIA PaCa-2 and BxPc-3 cells at the D10 values were 1.85–2.10. The ability for colony, spheroid formation, and tumorigenicity from cancer stem-like CD44+/CD24+ cells is significantly higher than that from non-cancer stem-like CD44−/CD24−cells. FACS data showed that CD44+/CD24+ cells were more highly enriched after X-rays compared to carbon ion irradiation at isoeffective doses. The RBE values for the carbon ion beam relative to X-ray at the D10 levels for CD44+/CD24+ cells were 2.0–2.19. The number of γH2AX foci in CD44−/CD24− cells was higher than that of CD44+/CD24+ cells after irradiation with either X-ray or carbon ion beam. The number of γH2AX foci in CD44+/CD24+ cells was almost the same in the early time, but it persists significantly longer in carbon ion beam irradiated cells compared to X-rays. Conclusions: Carbon ion beam has superior potential to kill pancreatic cancer stem cell-like cells, and prolonged induction of DNA damage might be one of the pivotal mechanisms of its high radiobiological effects compared to X-rays.

  17. Practical biological spread-out Bragg peak design of carbon beam

    CERN Document Server

    Kim, Chang Hyeuk; Chang, Seduk; Jang, Hong Suk; Kim, Jeong Hwan; Park, Dong Wook; Hwang, Won Taek; Yang, Tea-Keun

    2015-01-01

    The carbon beams show more advantages on the biological properties compared with proton beams in radiation therapy. The carbon beam shows high linear energy transfer (LET) to medium and it increases the relative biological effectiveness (RBE). To design spread-out Bragg peak (SOBP) of biological dose using carbon beam, a practical method was purposed by using the linear-quadratic (LQ) model and Geant4 based Monte Carlo simulation code. The various Bragg peak profiles and LET was calculated for each slice at the target region. To generate appropriate biological SOBP, a set of weighting factor, which is a power function in terms of energy step, was applied to the obtained each physical dose. The designed biological SOBP showed 1.34 % of uniformity.

  18. Allotropic conversion of carbon-related films by using energy beams

    International Nuclear Information System (INIS)

    Energy beams such as ion and laser beams are employed to convert of C60 molecules into another carbon allotropes. The ion beam deposition (IBD) technique is effective to study the nucleation process by changing several growth parameters (beam energy, substrate temperature and ion species). The 12CHx+ (x = 0-4) ions with different energies (50-200 eV) are incident on two kinds of substrates (Si(111) and Ir(100)/MgO(100)) at room temperature and 700 deg C. Immersed nanosize diamonds are found in amorphous films in all cases. The topological features obtained in IBD are compared with laser processing experiments

  19. Irradiation of 135 MeV/u carbon and neon beams for studies of radiation biology

    International Nuclear Information System (INIS)

    A heavy ion irradiation system was designed and constructed at RIKEN ring cyclotron facility for studies of radiation physics and radiation biology. Carbon and neon beams of 135 MeV/u were firstly used for the experiments. A pair of wobbler magnets and a scatterer were used for obtaining the uniform radiation field of about 10 cm in diameter. A parallel plate ionization chamber was used for dose monitoring. A range shifter was used for degrading the initial energy of the heavy ions. Precise depth dose distributions were measured by a small parallel plate ionization chamber and a variable length water column. LET (linear energy transfer) of the heavy ion radiation fields were measured by a parallel plate proportional chamber. From these basic measurements, biological experiments using these heavy ions are now carried out at this facility. (author)

  20. Amorphous track modelling of luminescence detector efficiency in proton and carbon beams

    DEFF Research Database (Denmark)

    Greilich, Steffen; Grzanka, Leszek; Bassler, Niels;

    be seriously hampered by variations in detector efficiency (light output per energy imparted) due to high-LET effects and gradients along the physical size (~mm) of the detector crystals. Amorphous track models (ATMs) such as the Ion-Gamma-Kill (IGK) approach by Katz and co-workers or the ECLaT code by Geiß et...... assumptions in a variety of detectors. The library also includes simple particle transportation or can be interfaced to external transport codes. We applied our code to RL and OSL data from fiber-coupled Al2O3:C-detectors in a proton (nominal energies 10 MeV to 60 MeV) and a carbon beam (270 MeV/u). Results...

  1. Nano-carbon black and carbon fiber as conductive materials for the diagnosing of the damage of concrete beam

    OpenAIRE

    Yining Ding; Zhipei Chen; Zhibo Han; Yulin Zhang; Torgal, Fernando Pacheco

    2013-01-01

    The nano-carbon black (NCB) and carbon fiber (CF) as electric conductive materials were added into the concrete. The effect of the NCB and CF on the mechanical properties and on the fractional change in resistance (FCR) of concrete was investigated. The relationships among the FCR, the strain of initial geometrical neutral axis (IGNA) and the beam damage degree were developed. The results showed that the relationship between the FCR and IGNA strain can be described by the First Or...

  2. Water equivalent thickness values of materials used in beams of protons, helium, carbon and iron ions.

    Science.gov (United States)

    Zhang, Rui; Taddei, Phillip J; Fitzek, Markus M; Newhauser, Wayne D

    2010-05-01

    Heavy charged particle beam radiotherapy for cancer is of increasing interest because it delivers a highly conformal radiation dose to the target volume. Accurate knowledge of the range of a heavy charged particle beam after it penetrates a patient's body or other materials in the beam line is very important and is usually stated in terms of the water equivalent thickness (WET). However, methods of calculating WET for heavy charged particle beams are lacking. Our objective was to test several simple analytical formulas previously developed for proton beams for their ability to calculate WET values for materials exposed to beams of protons, helium, carbon and iron ions. Experimentally measured heavy charged particle beam ranges and WET values from an iterative numerical method were compared with the WET values calculated by the analytical formulas. In most cases, the deviations were within 1 mm. We conclude that the analytical formulas originally developed for proton beams can also be used to calculate WET values for helium, carbon and iron ion beams with good accuracy. PMID:20371908

  3. Development of long-lived cluster and hybrid carbon stripper foils for high energy, high intensity ion beams

    International Nuclear Information System (INIS)

    We have developed thin and thick long-lived carbon stripper foils for high energy, high intensity ion beams. The foil thicknesses are about 10 μg/cm2 (cluster foil) and 200 μg/cm2 (hybrid foil) for thin and thick, respectively. The thin foil is made by a controlled DC-arc discharge (CDAD) method, by using the size effect of the carbon particles. The size effect was the difference between the carbon particle sizes emitted from the cathode and the anode electrodes in the DC arc discharge, in which the particle size from the cathode is large (0.3 μmφ) and the other is small (0.003 μmφ). The thin foils composed of large particle size are not mechanically strong, but long-lived under low energy ion bombardment with a 3.2 MeV, 2-3 μA Ne+ beam. The mean lifetime is 900 mC/cm2 in average which corresponds to 25 times longer than that of commercially available standard foils. In this method, the key point in producing long-lived foils is to control the amount of carbon particles ablated from the cathode by adjusting temperature at the cathode emission spot. The thick hybrid carbon foils (multi-layer thickness about 200 μg/cm2) have been developed for use in 800 MeV, H+ ion beam at the Proton Storage Ring (PSR) of Los Alamos National Laboratory. The thick foils are prepared by means of the controlled ACDC arc discharge (CADAD) method, and are mechanically strong. The lifetime measurements of thick foils made by various methods were carried out using 800 MeV, 85-100 μA proton beams in the PSR. The foils made by the CADAD method showed very long lifetime, compared to other foils tested. (author)

  4. Calculation of Lifetime of Charge-Exchanging Carbon Targets in Intense Heavy Ion Beams

    CERN Document Server

    Gikal, B N; Kazacha, V I; Kamanin, D V

    2005-01-01

    Influence of the radiation damage and sublimation effects on the lifetime of carbon targets used for the accelerated ion beam extraction from cyclotrons by the charge-exchanging method is considered. The theoretical models permitting evaluation of the carbon target lifetime depending on their and ion beam parameters are presented both for the radiation damage and sublimation effects. It is shown that for the U-400 cyclotron carbon targets 50 $\\mu$g/cm$^{2}$ thick and for the ion beam flux density up to 100 p$\\mu$A/cm$^{2}$ the main effect defining the carbon target lifetime is the radiation damage. If the carbon target thickness and the ion beam flux density are greater, the target lifetime is defined already by the sublimation effect. In this connection "casting pipes" can be formed in the target, affecting on the mean energy and the energy distribution dispersion of the ion beam flied through the target. Comparison of measured and calculated target lifetimes is carried out

  5. Particle beam radiation therapy using carbon ions and protons for oligometastatic lung tumors

    International Nuclear Information System (INIS)

    A study was undertaken to analyze the efficacy and feasibility of particle beam radiation therapy (PBRT) using carbon ions and protons for the treatment of patients with oligometastatic lung tumors. A total of 47 patients with 59 lesions who underwent PBRT for oligometastatic lung tumors between 2003 and 2011 were included in this study. Patient median age was 66 (range, 39–84) years. The primary tumor site was the colorectum in 11 patients (23.4%), lung in 10 patients (21.3%) and a variety of other sites in 26 patients (55.3%). Thirty-one patients (66%) received chemotherapy prior to PBRT. Thirty-three lesions were treated with 320-MeV carbon ions and 26 were treated with 150- or 210-Mev protons in 1–4 portals. A median total dose of 60 (range, 52.8–70.2) GyE was delivered at the isocenter in 8 (range, 4–26) fractions. The median follow-up time was 17 months. The local control, overall survival and progression-free survival rates at 2 years were 79%, 54 and 27% respectively. PBRT-related toxicities were observed; six patients (13%) had grade 2 toxicity (including grade 2 radiation pneumonitis in 2) and six patients (13%) had grade 3 toxicity. Univariate analysis indicated that patients treated with a biologically equivalent dose of 10 (BED10) <110 GyE10, had a significantly higher local recurrence rate. Local control rates were relatively lower in the subsets of patients with the colorectum as the primary tumor site. No local progression was observed in metastases from colorectal cancer irradiated with a BED10 ≥ 110 GyE10. There was no difference in treatment results between proton and carbon ion therapy. PRBT is well tolerated and effective in the treatment of oligometastatic lung tumors. To further improve local control, high-dose PBRT with a BED10 ≥ 110 GyE10 may be promising. Further investigation of PBRT for lung oligometastases is warranted

  6. Geant4 Simulation Study of Dose Distribution and Energy Straggling for Proton and Carbon Ion Beams in Water

    OpenAIRE

    Zhao Qiang; Zhang Zheng; Li Yang

    2016-01-01

    Dose distribution and energy straggling for proton and carbon ion beams in water are investigated by using a hadrontherapy model based on the Geant4 toolkit. By gridding water phantom in N×N×N voxels along X, Y and Z axes, irradiation dose distribution in all the voxels is calculated. Results indicate that carbon ion beams have more advantages than proton beams. Proton beams have bigger width of the Bragg peak and broader lateral dose distribution than carbon ion beams for the same position o...

  7. Strong Metal-Support Interaction: Growth of Individual Carbon Nanofibers from Amorphous Carbon Interacting with an Electron Beam

    DEFF Research Database (Denmark)

    Zhang, Wei; Kuhn, Luise Theil

    2013-01-01

    The article discusses the growth behavior of carbon nanofibers (CNFs). It mentions that CNFs can be synthesized using methods such as arc-discharge, laser ablation and chemical vapor deposition. It further states that CNFs can be grown from a physical mixing of amorphous carbon and CGO/Ni nanopar......The article discusses the growth behavior of carbon nanofibers (CNFs). It mentions that CNFs can be synthesized using methods such as arc-discharge, laser ablation and chemical vapor deposition. It further states that CNFs can be grown from a physical mixing of amorphous carbon and CGO....../Ni nanoparticles, devoid of any gaseous carbon source and external heating and stimulated by an electron beam in a 300 kilo volt transmission electron microscope....

  8. Analysis of the strength and stiffness of timber beams reinforced with carbon fiber and glass fiber

    OpenAIRE

    Juliano Fiorelli; Antonio Alves Dias

    2003-01-01

    An experimental analysis of pinewood beams (Pinus caribea var hondurensis) reinforced with glass and/or carbon fibers is discussed. The theoretical model employed to calculate the beam's bending strength takes into account the timber's ultimate limit states of tensile strength and failure by compression, considering a model of fragile elastic tension and plastic elastic compression. The validity of the theoretical model is confirmed by a comparison of the theoretical and experimental results,...

  9. Carbon beam extraction with 14.5 GHz electron cyclotron resonance ion source at Korea Atomic Energy Research Institute.

    Science.gov (United States)

    Lee, Cheol Ho; Oh, Byung-Hoon; Chang, Dae-Sik; Jeong, Sun-Chan

    2014-02-01

    A 14.5 GHz Electron Cyclotron Resonance ion source (ECRIS) has been made to produce C(4+) beam for using a carbon therapy facility and recently tested at KAERI. Highly charged carbon ions have been successfully extracted. When using only CO2 gas, the beam current of C(4+) was almost 14 μA at 15 kV extraction voltage. To get higher current of the C(4+) beam, while optimizing confinement magnetic field configuration (e.g., axial strengths at minimum and extraction side), gas-mixing (CO2/He), and biased disk were introduced. When the gas mixing ratio of the CO2/He gas is 1:8 at an operational pressure of 5 × 10(-7) mbar and the disk was biased to -150 V relative to the ion source body, the highest current of the C(4+) beam was achieved to be 50 μA, more than three times higher than previously observed only with CO2 gas. Some details on the operating conditions of the ECRIS were discussed. PMID:24593482

  10. Geant4 Simulation Study of Dose Distribution and Energy Straggling for Proton and Carbon Ion Beams in Water

    Directory of Open Access Journals (Sweden)

    Zhao Qiang

    2016-01-01

    Full Text Available Dose distribution and energy straggling for proton and carbon ion beams in water are investigated by using a hadrontherapy model based on the Geant4 toolkit. By gridding water phantom in N×N×N voxels along X, Y and Z axes, irradiation dose distribution in all the voxels is calculated. Results indicate that carbon ion beams have more advantages than proton beams. Proton beams have bigger width of the Bragg peak and broader lateral dose distribution than carbon ion beams for the same position of Bragg peaks. Carbon ion has a higher local ionization density and produces more secondary electrons than proton, so carbon ion beams can achieve a higher value of relative biological effectiveness.

  11. GPU-accelerated automatic identification of robust beam setups for proton and carbon-ion radiotherapy

    International Nuclear Information System (INIS)

    We demonstrate acceleration on graphic processing units (GPU) of automatic identification of robust particle therapy beam setups, minimizing negative dosimetric effects of Bragg peak displacement caused by treatment-time patient positioning errors. Our particle therapy research toolkit, RobuR, was extended with OpenCL support and used to implement calculation on GPU of the Port Homogeneity Index, a metric scoring irradiation port robustness through analysis of tissue density patterns prior to dose optimization and computation. Results were benchmarked against an independent native CPU implementation. Numerical results were in agreement between the GPU implementation and native CPU implementation. For 10 skull base cases, the GPU-accelerated implementation was employed to select beam setups for proton and carbon ion treatment plans, which proved to be dosimetrically robust, when recomputed in presence of various simulated positioning errors. From the point of view of performance, average running time on the GPU decreased by at least one order of magnitude compared to the CPU, rendering the GPU-accelerated analysis a feasible step in a clinical treatment planning interactive session. In conclusion, selection of robust particle therapy beam setups can be effectively accelerated on a GPU and become an unintrusive part of the particle therapy treatment planning workflow. Additionally, the speed gain opens new usage scenarios, like interactive analysis manipulation (e.g. constraining of some setup) and re-execution. Finally, through OpenCL portable parallelism, the new implementation is suitable also for CPU-only use, taking advantage of multiple cores, and can potentially exploit types of accelerators other than GPUs.

  12. Cancer stem cells: The potential of carbon ion beam radiation and new radiosensitizers (Review).

    Science.gov (United States)

    Baek, Sung-Jae; Ishii, Hideshi; Tamari, Keisuke; Hayashi, Kazuhiko; Nishida, Naohiro; Konno, Masamitsu; Kawamoto, Koichi; Koseki, Jun; Fukusumi, Takahito; Hasegawa, Shinichiro; Ogawa, Hisataka; Hamabe, Atsushi; Miyo, Masaaki; Noguchi, Kozo; Seo, Yuji; Doki, Yuichiro; Mori, Masaki; Ogawa, Kazuhiko

    2015-11-01

    Cancer stem cells (CSCs) are a small population of cells in cancer with stem-like properties such as cell proliferation, multiple differentiation and tumor initiation capacities. CSCs are therapy-resistant and cause cancer metastasis and recurrence. One key issue in cancer therapy is how to target and eliminate CSCs, in order to cure cancer completely without relapse and metastasis. To target CSCs, many cell surface markers, DNAs and microRNAs are considered as CSC markers. To date, the majority of the reported markers are not very specific to CSCs and are also present in non-CSCs. However, the combination of several markers is quite valuable for identifying and targeting CSCs, although more specific identification methods are needed. While CSCs are considered as critical therapeutic targets, useful treatment methods remain to be established. Epigenetic gene regulators, microRNAs, are associated with tumor initiation and progression. MicroRNAs have been recently considered as promising therapeutic targets, which can alter the therapeutic resistance of CSCs through epigenetic modification. Moreover, carbon ion beam radiotherapy is a promising treatment for CSCs. Evidence indicates that the carbon ion beam is more effective against CSCs than the conventional X-ray beam. Combination therapies of radiosensitizing microRNAs and carbon ion beam radiotherapy may be a promising cancer strategy. This review focuses on the identification and treatment resistance of CSCs and the potential of microRNAs as new radiosensitizers and carbon ion beam radiotherapy as a promising therapeutic strategy against CSCs. PMID:26330103

  13. Measurement of contact resistance of multiwall carbon nanotubes by electrical contact using a focused ion beam

    International Nuclear Information System (INIS)

    Carbon nanotubes (CNTs) have found many potential applications but using CNTs as building blocks for nanoelectronics is still challenging. Various micro- and nanofabrication techniques including focused ion beam (FIB) are therefore being developed for combining CNTs into a nanodevice or to help assess the electrical properties of integrated CNTs. In this paper, multiwall carbon nanotubes (MWNTs) are assembled between a pair of gold (Au) electrodes by dielectrophoresis (DEP). Contact resistances of MWNT-Au and, in particular, MWNT-MWNT are measured with the help of making electrical connections between a MWNT and electrodes by FIB induced tungsten deposition. A method for resistance calculation is presented which considers the contact length of MWNTs. Under the conditions of this research, measured conducting resistances of MWNTs were from 1–10 kΩ/μm and the contact resistance of MWNTs with Au was around 100 kΩ μm. The contact resistance between MWNTs varied depending on contact configurations and could be as low as 50 KΩ. The effect of FIB parameters on the measurement results is discussed.

  14. Measurement of contact resistance of multiwall carbon nanotubes by electrical contact using a focused ion beam

    Energy Technology Data Exchange (ETDEWEB)

    An Libao, E-mail: lan@heut.edu.cn [College of Mechanical Engineering, Hebei United University, Tangshan, Hebei, 063009 (China); Friedrich, Craig R. [Department of Mechanical Engineering - Engineering Mechanics, Michigan Technological University, Houghton, MI 49931 (United States)

    2012-02-01

    Carbon nanotubes (CNTs) have found many potential applications but using CNTs as building blocks for nanoelectronics is still challenging. Various micro- and nanofabrication techniques including focused ion beam (FIB) are therefore being developed for combining CNTs into a nanodevice or to help assess the electrical properties of integrated CNTs. In this paper, multiwall carbon nanotubes (MWNTs) are assembled between a pair of gold (Au) electrodes by dielectrophoresis (DEP). Contact resistances of MWNT-Au and, in particular, MWNT-MWNT are measured with the help of making electrical connections between a MWNT and electrodes by FIB induced tungsten deposition. A method for resistance calculation is presented which considers the contact length of MWNTs. Under the conditions of this research, measured conducting resistances of MWNTs were from 1-10 k{Omega}/{mu}m and the contact resistance of MWNTs with Au was around 100 k{Omega} {mu}m. The contact resistance between MWNTs varied depending on contact configurations and could be as low as 50 K{Omega}. The effect of FIB parameters on the measurement results is discussed.

  15. Advanced Electron Beam Ion Sources (EBIS) for 2-nd generation carbon radiotherapy facilities

    International Nuclear Information System (INIS)

    In this work we analyze how advanced Electron Beam Ion Sources (EBIS) can facilitate the progress of carbon therapy facilities. We will demonstrate that advanced ion sources enable operation of 2-nd generation ion beam therapy (IBT) accelerators. These new accelerator concepts with designs dedicated to IBT provide beams better suited for therapy and, are more cost efficient than contemporary IBT facilities. We will give a sort overview of the existing new IBT concepts and focus on those where ion source technology is the limiting factor. We will analyse whether this limitation can be overcome in the near future thanks to ongoing EBIS development

  16. Advanced Electron Beam Ion Sources (EBIS) for 2-nd generation carbon radiotherapy facilities

    Science.gov (United States)

    Shornikov, A.; Wenander, F.

    2016-04-01

    In this work we analyze how advanced Electron Beam Ion Sources (EBIS) can facilitate the progress of carbon therapy facilities. We will demonstrate that advanced ion sources enable operation of 2-nd generation ion beam therapy (IBT) accelerators. These new accelerator concepts with designs dedicated to IBT provide beams better suited for therapy and, are more cost efficient than contemporary IBT facilities. We will give a sort overview of the existing new IBT concepts and focus on those where ion source technology is the limiting factor. We will analyse whether this limitation can be overcome in the near future thanks to ongoing EBIS development.

  17. Analysis of the strength and stiffness of timber beams reinforced with carbon fiber and glass fiber

    Directory of Open Access Journals (Sweden)

    Juliano Fiorelli

    2003-06-01

    Full Text Available An experimental analysis of pinewood beams (Pinus caribea var hondurensis reinforced with glass and/or carbon fibers is discussed. The theoretical model employed to calculate the beam's bending strength takes into account the timber's ultimate limit states of tensile strength and failure by compression, considering a model of fragile elastic tension and plastic elastic compression. The validity of the theoretical model is confirmed by a comparison of the theoretical and experimental results, while the efficiency of the fiber reinforcement is corroborated by the increased strength and stiffness of the reinforced timber beams.

  18. Beam asymmetry Σ in π0 photoproduction off protons bound in carbon nuclei

    International Nuclear Information System (INIS)

    In order to study the dynamics of the inner components of the nucleon, its excitation spectrum is investigated through meson-photoproduction. Due to the strong overlap of the nucleon's excited states, it is insufficient to determine the cross section only. To identify all resonance contributions unambiguously, single and double polarization observables have to be measured. At the Crystal Barrel experiment at ELSA in Bonn, this is achieved utilizing linearly or circularly polarized photons and longitudinally or transversely polarized nucleons. Polarized protons are realized in a butanol target, which consists of hydrogen, oxygen and carbon. A pure carbon target was used to perform a background measurement. The results for the beam asymmetry Σ in π0 photoproduction, obtained with a carbon target and a linearly polarized photon beam, are presented. Furthermore, the influence of carbon background on the measured polarization observables is discussed.

  19. Reinforced concrete T-beams externally prestressed with unbonded carbon fiber-reinforced polymer tendons

    DEFF Research Database (Denmark)

    Bennitz, Anders; Nilimaa, Jonny; Ravn, Dorthe Lund; Schmidt, Jacob W.; Täljsten, Björn; Goltermann, Per

    2012-01-01

    This study describes a series of experiments examining the behavior of seven beams prestressed with unbonded external carbon fiberreinforced polymer (CFRP) tendons anchored using a newly developed anchorage and post-tensioning system. The effects of varying the initial tendon depth, prestressing...... force, and the presence of a deviator were investigated. The results were compared to those observed with analogous beams prestressed with steel tendons, common beam theory, and predictions made using an analytical model adapted from the literature. It was found that steel and CFRP tendons had very...... similar effects on the structural behavior of the strengthened beams; the minor differences that were observed are attributed to the difference between the modulus of elasticity of the CFRP and the steel used in the tests. The models predicted the beams' load-bearing behavior accurately but were less...

  20. Average Frequency – RA Value for Reinforced Concrete Beam Strengthened with Carbon Fibre Sheet

    Directory of Open Access Journals (Sweden)

    Mohamad M. Z.

    2016-01-01

    Full Text Available Acoustic Emission (AE is one of the tools that can be used to detect the crack and to classify the type of the crack of reinforced concrete (RC structure. Dislocation or movement of the material inside the RC may release the transient elastic wave. In this situation, AE plays important role whereby it can be used to capture the transient elastic wave and convert it into AE parameters such as amplitude, count, rise time and duration. Certain parameter can be used directly to evaluate the crack behavior. But in certain cases, the AE parameter needs to add and calculate by using related formula in order to observe the behavior of the crack. Using analysis of average frequency and RA value, the crack can be classified into tensile or shear cracks. In this study, seven phases of increasing static load were used to observe the crack behavior. The beams were tested in two conditions. For the first condition, the beams were tested in original stated without strengthened with carbon fibre sheet (CFS at the bottom of the beam or called as tension part of the beam. For the second condition, the beams were strengthened with CFS at the tension part of the beam. It was found that, beam wrapped with CFS enhanced the strength of the beams in term of maximum ultimate load. Based on the relationship between average frequency (AF and RA value, the cracks of the beams can be classified.

  1. Quasi-steady carbon plasma source for neutral beam injector

    International Nuclear Information System (INIS)

    Carbon plasma is successfully sustained during 1000 s without any carrier gas in the bucket type ionization chamber with cusp magnetic field. Every several seconds, seed plasmas having ∼3 ms duration time are injected into the ionization chamber by a shunting arch plasma gun. The weakly ionized carbon plasma ejected from the shunting arch is also ionized by 2.45 GHz microwave at the electron cyclotron resonance surface and the plasma can be sustained even in the interval of gun discharges. Control of the gun discharge interval allows to keep high pressure and to sustain the plasma for long duration

  2. Quasi-steady carbon plasma source for neutral beam injector.

    Science.gov (United States)

    Koguchi, H; Sakakita, H; Kiyama, S; Shimada, T; Sato, Y; Hirano, Y

    2014-02-01

    Carbon plasma is successfully sustained during 1000 s without any carrier gas in the bucket type ionization chamber with cusp magnetic field. Every several seconds, seed plasmas having ∼3 ms duration time are injected into the ionization chamber by a shunting arch plasma gun. The weakly ionized carbon plasma ejected from the shunting arch is also ionized by 2.45 GHz microwave at the electron cyclotron resonance surface and the plasma can be sustained even in the interval of gun discharges. Control of the gun discharge interval allows to keep high pressure and to sustain the plasma for long duration. PMID:24593646

  3. ELECTRO-THERMAL EFFECTS AND DEFORMATION RESPONSE OF CARBON FIBER MAT CEMENT BEAMS

    Institute of Scientific and Technical Information of China (English)

    ZhuSirong; LiZhuoqiu; SongXianhui

    2003-01-01

    A carbon fiber mat is a sheet composed of intercrossing short carbon fibers, which has more stable and lower electrical resistivity compared with dispersed short carbon fiber mixed in cement. Thereby carbon fiber mat cement could exhibit obvious electro-thermal effect. When electrified, the temperature of composite structures made up of cement mortar and carbon fiber mat will rise rapidly. If the temperature field is not uniform, temperature difference will cause structures to deform, which can be used to adjust the deformation of structures. The temperature field and deformation response driven by the electro-thermal effects of a type of carbon fiber mat cement beams are studied. Firstly, the temperature and deformation responses are studied using theories of thermal conduction and elasticity. Secondly, experimental results are given to verify the theoretical solution. These two parts lay the foundation for temperature and deformation adjustment.

  4. Geant4 simulation for a study of a possible use of carbon ion pencil beams for the treatment of ocular melanomas with the active scanning system at CNAO

    Science.gov (United States)

    Farina, E.; Piersimoni, P.; Riccardi, C.; Rimoldi, A.; Tamborini, A.; Ciocca, M.

    2015-12-01

    The aim of this work was to study a possible use of carbon ion pencil beams (delivered with active scanning modality) for the treatment of ocular melanomas at the Centro Nazionale di Adroterapia Oncologica (CNAO). The promising aspect of carbon ions radiotherapy for the treatment of this disease lies in its superior relative radio-biological effectiveness (RBE). The Monte Carlo (MC) Geant4 10.00 toolkit was used to simulate the complete CNAO extraction beamline, with the active and passive components along it. A human eye modeled detector, including a realistic target tumor volume, was used as target. Cross check with previous studies at CNAO using protons allowed comparisons on possible benefits on using such a technique with respect to proton beams. Experimental data on proton and carbon ion beams transverse distributions were used to validate the simulation.

  5. Experimental control of the beam properties of laser-accelerated protons and carbon ions

    International Nuclear Information System (INIS)

    The laser generation of energetic high quality beams of protons and heavier ions has opened up the door to a plethora of applications. These beams are usually generated by the interaction of a short pulse high power laser with a thin metal foil target. They could already be applied to probe transient phenomena in plasmas and to produce warm dense matter by isochoric heating. Other applications such as the production of radioisotopes and tumour radiotherapy need further research to be put into practice. To meet the requirements of each application, the properties of the laser-accelerated particle beams have to be controlled precisely. In this thesis, experimental means to control the beam properties of laser-accelerated protons and carbon ions are investigated. The production and control of proton and carbon ion beams is studied using advanced ion source designs: Experiments concerning mass-limited (i.e. small and isolated) targets are conducted. These targets have the potential to increase both the number and the energy of laser-accelerated protons. Therefore, the influence of the size of a plane foil target on proton beam properties is measured. Furthermore, carbon ion sources are investigated. Carbon ions are of particular interest in the production of warm dense matter and in cancer radiotherapy. The possibility to focus carbon ion beams is investigated and a simple method for the production of quasi-monoenergetic carbon ion beams is presented. This thesis also provides an insight into the physical processes connected to the production and the control of laser-accelerated ions. For this purpose, laser-accelerated protons are employed to probe plasma phenomena on laser-irradiated targets. Electric fields evolving on the surface of laser-irradiated metal foils and hollow metal foil cylinders are investigated. Since these fields can be used to displace, collimate or focus proton beams, understanding their temporal and spatial evolution is crucial for the design of

  6. Experimental control of the beam properties of laser-accelerated protons and carbon ions

    Energy Technology Data Exchange (ETDEWEB)

    Amin, Munib

    2008-12-15

    The laser generation of energetic high quality beams of protons and heavier ions has opened up the door to a plethora of applications. These beams are usually generated by the interaction of a short pulse high power laser with a thin metal foil target. They could already be applied to probe transient phenomena in plasmas and to produce warm dense matter by isochoric heating. Other applications such as the production of radioisotopes and tumour radiotherapy need further research to be put into practice. To meet the requirements of each application, the properties of the laser-accelerated particle beams have to be controlled precisely. In this thesis, experimental means to control the beam properties of laser-accelerated protons and carbon ions are investigated. The production and control of proton and carbon ion beams is studied using advanced ion source designs: Experiments concerning mass-limited (i.e. small and isolated) targets are conducted. These targets have the potential to increase both the number and the energy of laser-accelerated protons. Therefore, the influence of the size of a plane foil target on proton beam properties is measured. Furthermore, carbon ion sources are investigated. Carbon ions are of particular interest in the production of warm dense matter and in cancer radiotherapy. The possibility to focus carbon ion beams is investigated and a simple method for the production of quasi-monoenergetic carbon ion beams is presented. This thesis also provides an insight into the physical processes connected to the production and the control of laser-accelerated ions. For this purpose, laser-accelerated protons are employed to probe plasma phenomena on laser-irradiated targets. Electric fields evolving on the surface of laser-irradiated metal foils and hollow metal foil cylinders are investigated. Since these fields can be used to displace, collimate or focus proton beams, understanding their temporal and spatial evolution is crucial for the design of

  7. Dosimetric characterization of a microDiamond detector in clinical scanned carbon ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Marinelli, Marco; Prestopino, G., E-mail: giuseppe.prestopino@uniroma2.it; Verona, C.; Verona-Rinati, G. [INFN—Dipartimento di Ingegneria Industriale, Università di Roma “Tor Vergata,” Via del Politecnico 1, Roma 00133 (Italy); Ciocca, M.; Mirandola, A.; Mairani, A. [Fondazione CNAO, Strada Campeggi 53, Pavia 27100 (Italy); Raffaele, L. [INFN—Laboratori Nazionali del Sud, Via S. Sofia 62, Catania 95123, Italy and Fondazione CNAO, Strada Campeggi 53, Pavia 27100 (Italy); Magro, G. [INFN—Dipartimento di Fisica, Università degli Studi di Pavia, Via U. Bassi 6, Pavia 27100, Italy and Fondazione CNAO, Strada Campeggi 53, Pavia 27100 (Italy)

    2015-04-15

    Purpose: To investigate for the first time the dosimetric properties of a new commercial synthetic diamond detector (PTW microDiamond) in high-energy scanned clinical carbon ion beams generated by a synchrotron at the CNAO facility. Methods: The detector response was evaluated in a water phantom with actively scanned carbon ion beams ranging from 115 to 380 MeV/u (30–250 mm Bragg peak depth in water). Homogeneous square fields of 3 × 3 and 6 × 6 cm{sup 2} were used. Short- and medium-term (2 months) detector response stability, dependence on beam energy as well as ion type (carbon ions and protons), linearity with dose, and directional and dose-rate dependence were investigated. The depth dose curve of a 280 MeV/u carbon ion beam, scanned over a 3 × 3 cm{sup 2} area, was measured with the microDiamond detector and compared to that measured using a PTW Advanced Markus ionization chamber, and also simulated using FLUKA Monte Carlo code. The detector response in two spread-out-Bragg-peaks (SOBPs), respectively, centered at 9 and 21 cm depths in water and calculated using the treatment planning system (TPS) used at CNAO, was measured. Results: A negligible drift of detector sensitivity within the experimental session was seen, indicating that no detector preirradiation was needed. Short-term response reproducibility around 1% (1 standard deviation) was found. Only 2% maximum variation of microDiamond sensitivity was observed among all the evaluated proton and carbon ion beam energies. The detector response showed a good linear behavior. Detector sensitivity was found to be dose-rate independent, with a variation below 1.3% in the evaluated dose-rate range. A very good agreement between measured and simulated Bragg curves with both microDiamond and Advanced Markus chamber was found, showing a negligible LET dependence of the tested detector. A depth dose curve was also measured by positioning the microDiamond with its main axis oriented orthogonally to the beam

  8. Future carbon beams at SPIRAL1 facility: Which method is the most efficient?

    International Nuclear Information System (INIS)

    Compared to in-flight facilities, Isotope Separator On-Line ones can in principle produce significantly higher radioactive ion beam intensities. On the other hand, they have to cope with delays for the release and ionization which make the production of short-lived isotopes ion beams of reactive and refractory elements particularly difficult. Many efforts are focused on extending the capabilities of ISOL facilities to those challenging beams. In this context, the development of carbon beams is triggering interest [H. Frånberg, M. Ammann, H. W. Gäggeler, and U. Köster, Rev. Sci. Instrum. 77, 03A708 (2006); M. Kronberger, A. Gottberg, T. M. Mendonca, J. P. Ramos, C. Seiffert, P. Suominen, and T. Stora, in Proceedings of the EMIS 2012 [Nucl. Instrum. Methods Phys. Res. B Production of molecular sideband radioisotope beams at CERN-ISOLDE using a Helicon-type plasma ion source (to be published)]: despite its refractory nature, radioactive carbon beams can be produced from molecules (CO or CO2), which can subsequently be broken up and multi-ionized to the required charge state in charge breeders or ECR sources. This contribution will present results of experiments conducted at LPSC with the Phoenix charge breeder and at GANIL with the Nanogan ECR ion source for the ionization of carbon beams in the frame of the ENSAR and EMILIE projects. Carbon is to date the lightest condensable element charge bred with an ECR ion source. Charge breeding efficiencies will be compared with those obtained using Nanogan ECRIS and charge breeding times will be presented as well

  9. Reactions of carbon atoms in pulsed molecular beams

    Energy Technology Data Exchange (ETDEWEB)

    Reisler, H. [Univ. of Southern California, Los Angeles (United States)

    1993-12-01

    This research program consists of a broad scope of experiments designed to unravel the chemistry of atomic carbon in its two spin states, P and D, by using well-controlled initial conditions and state-resolved detection of products. Prerequisite to the proposed studies (and the reason why so little is known about carbon atom reactions), is the development of clean sources of carbon atoms. Therefore, in parallel with the studies of its chemistry and reaction dynamics, the authors continuously explore new, state-specific and efficient ways of producing atomic carbon. In the current program, C({sup 3}P) is produced via laser ablation of graphite, and three areas of study are being pursued: (i) exothermic reactions with small inorganic molecules (e.g., O{sub 2}, N{sub 2}O, NO{sub 2}) that can proceed via multiple pathways; (ii) the influence of vibrational and translational energy on endothermic reactions involving H-containing reactants that yield CH products (e.g., H{sub 2}O H{sub 2}CO); (iii) reactions of C({sup 3}P) with free radicals (e.g., HCO, CH{sub 3}O). In addition, the authors plan to develop a source of C({sup 1}D) atoms by exploiting the pyrolysis of diazotetrazole and its salts in the ablation source. Another important goal involves collaboration with theoreticians in order to obtain relevant potential energy surfaces, rationalize the experimental results and predict the roles of translational and vibrational energies.

  10. Characterization of laser beam interaction with carbon materials

    International Nuclear Information System (INIS)

    This paper presents simulation and experimental results for the exposure of some carbon-based materials to alexandrite and Nd3+:YAG (yttrium aluminum garnet) laser radiation. Simulation of the heating effects was carried out using the COMSOL Multiphysics 3.5 package for samples of carbon-based P7295-2 fiber irradiated using an alexandrite laser and carbon-based P4396-2 fiber irradiated using an Nd3+:YAG laser, as well as by applying finite element modeling for P7295-2 samples irradiated using an Nd3+:YAG laser. In the experimental part, P7295-2 samples were exposed to alexandrite laser radiation while samples of carbon-based composite 3D C/C were exposed to Nd3+:YAG laser radiation. Micrographs of the laser induced craters were obtained by light and scanning electron microscopy, and the images analyzed using the ImageJ software. The results obtained enable identification of the laser–material interaction spots, and characterization of the laser induced changes in the materials investigated. (paper)

  11. DNA damage response signaling in lung adenocarcinoma A549 cells following gamma and carbon beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Ghosh, Somnath [Radiation Biology and Health Sciences Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085 (India); Narang, Himanshi, E-mail: himinarang@gmail.com [Radiation Biology and Health Sciences Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085 (India); Sarma, Asitikantha [Radiation Biology Laboratory, Inter University Accelerator Centre, Aruna Asaf Ali Marg, New Delhi 110 067 (India); Krishna, Malini [Radiation Biology and Health Sciences Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085 (India)

    2011-11-01

    Carbon beams (5.16 MeV/u, LET = 290 keV/{mu}m) are high linear energy transfer (LET) radiation characterized by higher relative biological effectiveness than low LET radiation. The aim of the current study was to determine the signaling differences between {gamma}-rays and carbon ion-irradiation. A549 cells were irradiated with 1 Gy carbon or {gamma}-rays. Carbon beam was found to be three times more cytotoxic than {gamma}-rays despite the fact that the numbers of {gamma}-H2AX foci were same. Percentage of cells showing ATM/ATR foci were more with {gamma}-rays however number of foci per cell were more in case of carbon irradiation. Large BRCA1 foci were found in all carbon irradiated cells unlike {gamma}-rays irradiated cells and prosurvival ERK pathway was activated after {gamma}-rays irradiation but not carbon. The noteworthy finding of this study is the early phase apoptosis induction by carbon ions. In the present study in A549 lung adenocarcinoma, authors conclude that despite activation of same repair molecules such as ATM and BRCA1, differences in low and high LET damage responses might be due to their distinct macromolecular complexes rather than their individual activation and the activation of cytoplasmic pathways such as ERK, whether it applies to all the cell lines need to be further explored.

  12. Electrochemical behavior of steel 12Kh18N10T irradiated by a pulsed electron beam

    International Nuclear Information System (INIS)

    Results are given in the present work for studying the electrochemical behavior of steel 12Kh18N10T irradiated by a pulsed electron beam. The electrochemical behavior was studied by means of anodic polarization curves in 1% HCl solution at room temperature. The authors established that for a marked increase in the corrosion resistance of steel 12Kh18N10T with irradiation by a pulsed electron beam it is necessary that the surface temperature is sufficient for evaporation of a thin layer and purification of the surface from undesirable impurities. Use of pulsed electron beams with these parameters makes it possible to increase the corrosion resistance of this steel by several factors of ten. The possibility has been demonstrated of using electron beams of nanosecond duration for alloying the surface layers of steels with the aim of improving their corrosion resistance

  13. Electron beam welding of 180 MM thick 15 CD 9 10 steel

    International Nuclear Information System (INIS)

    In the context of heavy component welding for the nuclear industry, an electron beam weldability study was undertaken on 180 mn thick 15 CD 9 10 (21/4 Cr-1-1 Mo) steel plates. The purpose of this study, performed using the CEA/STA 100 kW electron beam welding facilities, was to determine the welding parameters assuring sound weld beads during nominal conditions and to assess the electron beam weldability of this grade of steel in the event of very thick plates. This paper describes the procedure adopted to determine the welding parameters and gives an initial metallurgical characterization of the welds obtained for as-welded and stress-relieved states. The study confirms the operating feasibility of electron beam welding on 180 mn thick 15 CD 9.10 steel plates, during nominal conditions. However, problems related to beam start and extinction are disregarded, as are those concerning magnetic remanence. The effects on weld beam compactness of variations in the welding parameters were analyzed. Acceptable latitudes amply suffice in most cases to ensure satisfactory result reproducibility. The beam circular vibratory amplitude would appear to be a highly sensitive welding parameter. The HAZ cooling rate, the microstructure obtained consisting mainly of martensite and the hardness values measured in both heat-affected and fusion zones (high for as-welded states and leveled after stress-relieving) lead us to expect satisfactory mechanical properties for these welds. (authors). 4 refs., 6 figs

  14. Preliminary studies of PQS PET detector module for dose verification of carbon beam therapy

    Science.gov (United States)

    Kim, H.-I.; An, S. Jung; Lee, C. Y.; Jo, W. J.; Min, E.; Lee, K.; Kim, Y.; Joung, J.; Chung, Y. H.

    2014-05-01

    PET imaging can be used to verify dose distributions of therapeutic particle beams such as carbon ion beams. The purpose of this study was to develop a PET detector module which was designed for an in-beam PET scanner geometry integrated into a carbon beam therapy system, and to evaluate its feasibility as a monitoring system of patient dose distribution. A C-shaped PET geometry was proposed to avoid blockage of the carbon beam by the detector modules. The proposed PET system consisted of 14 detector modules forming a bore with 30.2 cm inner diameter for brain imaging. Each detector module is composed of a 9 × 9 array of 4.0 mm × 4.0 mm × 20.0 mm LYSO crystal module optically coupled with four 29 mm diameter PMTs using Photomultiplier-quadrant-sharing (PQS) technique. Because the crystal pixel was identified based upon the distribution of scintillation lights of four PMTs, the design of the reflector between crystal elements should be well optimized. The optical design of reflectors was optimized using DETECT2000, a Monte Carlo code for light photon transport. A laser-cut reflector set was developed using the Enhanced Specular Reflector (ESR, 3M Co.) mirror-film with a high reflectance of 98% and a thickness of 0.064 mm. All 81 crystal elements of detector module were identified. Our result demonstrates that the C-shaped PET system is under development and we present the first reconstructed image.

  15. Preliminary studies of PQS PET detector module for dose verification of carbon beam therapy

    International Nuclear Information System (INIS)

    PET imaging can be used to verify dose distributions of therapeutic particle beams such as carbon ion beams. The purpose of this study was to develop a PET detector module which was designed for an in-beam PET scanner geometry integrated into a carbon beam therapy system, and to evaluate its feasibility as a monitoring system of patient dose distribution. A C-shaped PET geometry was proposed to avoid blockage of the carbon beam by the detector modules. The proposed PET system consisted of 14 detector modules forming a bore with 30.2 cm inner diameter for brain imaging. Each detector module is composed of a 9 × 9 array of 4.0 mm × 4.0 mm × 20.0 mm LYSO crystal module optically coupled with four 29 mm diameter PMTs using Photomultiplier-quadrant-sharing (PQS) technique. Because the crystal pixel was identified based upon the distribution of scintillation lights of four PMTs, the design of the reflector between crystal elements should be well optimized. The optical design of reflectors was optimized using DETECT2000, a Monte Carlo code for light photon transport. A laser-cut reflector set was developed using the Enhanced Specular Reflector (ESR, 3M Co.) mirror-film with a high reflectance of 98% and a thickness of 0.064 mm. All 81 crystal elements of detector module were identified. Our result demonstrates that the C-shaped PET system is under development and we present the first reconstructed image

  16. Interfacial electrical properties of ion-beam sputter deposited amorphous carbon on silicon

    Science.gov (United States)

    Khan, A. A.; Woollam, J. A.; Chung, Y.; Banks, B.

    1983-01-01

    Amorphous, 'diamond-like' carbon films have been deposited on Si substrates, using ion-beam sputtering. The interfacial properties are studied using capacitance and conductance measurements. Data are analyzed using existing theories for interfacial electrical properties. The density of electronic states at the interface, along with corresponding time constants are determined.

  17. Reinforced concrete T-beams externally prestressed with unbonded carbon fiber-reinforced polymer tendons

    DEFF Research Database (Denmark)

    Bennitz, Anders; Nilimaa, Jonny; Ravn, Dorthe Lund;

    2012-01-01

    This study describes a series of experiments examining the behavior of seven beams prestressed with unbonded external carbon fiberreinforced polymer (CFRP) tendons anchored using a newly developed anchorage and post-tensioning system. The effects of varying the initial tendon depth, prestressing ...

  18. Influence of electron beam irradiation on physicochemical properties of poly(trimethylene carbonate)

    NARCIS (Netherlands)

    Jozwiakowska, Joanna; Wach, Radoslaw A.; Rokita, Bozena; Ulanski, Piotr; Nalawade, Sameer P.; Grijpma, Dirk W.; Feijen, Jan; Rosiak, Janusz M.

    2011-01-01

    Electron beam (EB) irradiation of poly(trimethylene carbonate) (PTMC), an amorphous, biodegradable polymer used in the field of biomaterials, results in predominant cross-linking and finally in the formation of gel fraction, thus enabling modification of physicochemical properties of this material w

  19. Measurement of neutral current coherent neutral pion production on carbon in a few-GeV neutrino beam

    OpenAIRE

    Kurimoto, Y; Alcaraz-Aunion, J. L.; Brice, S J; Bugel, L.; Catala-Perez, J.; Cheng, G.; Conrad, J.M.; Djurcic, Z.; Dore, U.; Finley, D. A.; Franke, A. J.; C. Giganti; Gomez-Cadenas, J. J.; Guzowski, P.; Hanson, A.

    2010-01-01

    The SciBooNE Collaboration reports a measurement of neutral current coherent neutral pion production on carbon by a muon neutrino beam with average energy 0.8 GeV. The separation of coherent from inclusive neutral pion production has been improved by detecting recoil protons from resonant neutral pion production. We measure the ratio of the neutral current coherent neutral pion production to total charged current cross sections to be (1.16 +/- 0.24) x 10-2. The ratio of charged current cohere...

  20. Analysis of carbon in SrTiO3 grown by hybrid molecular beam epitaxy

    International Nuclear Information System (INIS)

    Secondary ion mass spectroscopy (SIMS) was used to investigate carbon impurity concentrations in stoichiometric SrTiO3 films grown by a hybrid molecular beam epitaxy approach that uses an effusion cell to supply strontium, a rf plasma source for oxygen and a metal organic titanium source (titanium tetra isopropoxide). The carbon concentration in the films was measured as a function of growth parameters. At sufficiently high growth temperatures (>800 degree sign C), the films contain a few ppm of carbon. The challenges in accurately quantifying low carbon concentrations are discussed. A carbon-containing contamination layer is detected on the surfaces of SrTiO3 substrates and air-exposed films by SIMS and in scanning transmission electron microscopy. The contamination layer could be removed by high-temperature predeposition oxygen plasma cleaning.

  1. Intense heavy ion beam-induced temperature effects in carbon-based stripper foils

    International Nuclear Information System (INIS)

    At the future FAIR facility, reliably working solid carbon stripper foils are desired for providing intermediate charge states to SIS18. With the expected high beam intensities, the foils experience enhanced degradation and limited lifetime due to severe radiation damage, stress waves, and thermal effects. This work presents systematic measurements of the temperature of different carbon-based stripper foils (amorphous, diamond-like, and carbon-nanotube based) exposed to 4.8 MeV/u U, Bi, and Au beams of different pulse intensities. Thermal and spectroscopic analyses were performed by means of infrared thermography and Fourier transform infrared spectroscopy. The resulting temperature depends on the foil thickness and strongly increases with increasing pulse intensity and repetition rate. (author)

  2. Alanine Radiation Detectors in Therapeutic Carbon Ion Beams

    DEFF Research Database (Denmark)

    Herrmann, Rochus; Jäkel, Oliver; Palmans, Hugo;

        Radiotherapy with particles is getting more attention in Europe. New facilities for protons and heavier ions are finished, or near to the final status, some more are planed. Particle therapy with heavy ions is a challenge to dosimetry, since mixed particle fields occur in the peak region...... of the depth dose curves. Solid state detectors, such as diamond detectors, radiochromic films, TLDs and the amino acid alanine are used due to there good spatial resolution. If used in particle beams their response often exhibits a dependence on particle energy and type, so the acquired signal is not always...... proportional to absorbed dose. A model by Hansen and Olsen, based on the Track Structure Theory is available, which can predict the relative efficiency of some detectors, when the particle spectrum is known. For alanine detectors the model was successfully validated by Hansen and Olsen for several ion species...

  3. Surface analysis and a novel application of carbon sheet pump in the GAMMA 10 tandem mirror

    International Nuclear Information System (INIS)

    Samples of carbon sheet pump (CSP) exposed to fast neutrals have been analyzed by using microscopic techniques in order to improve the performance of CSP and to examine the applicability of CSP to actual devices. It has been confirmed from the microscopic viewpoint for the first time that fast neutrals emitted from plasmas generated by the actual confinement device (GAMMA 10) are trapped by the C/C material. A numerical simulation is performed by means of the Monte Carlo simulation code TRIM (ver. TRVMC95) for the sake of the evaluation of the results obtained by elastic recoil detection technique. CSP has been newly applied to the shine-through beam dump of a neutral beam injector in order to test the pumping effect of CSP under the conditions of high heat and particle load (several MW/m2 and 2.5x1021 H/m2 s at the beam center, respectively). It also has been found from pressure-balance analysis that 80% of incident particles are trapped by CSP

  4. Design of optic system for 500 keV/10 mA electron beam machine

    International Nuclear Information System (INIS)

    In the 1995/1996 Research Year design of Electron Beam Machine components i.e. : Electron Source, High Voltage Supply, Accelerator Tube, Focussing System, Steering System, Scanning System, Vacuum System, Radiation Facility and Conveyer System also Electronics and Control System was carried out. This paper describes the design of Focussing, Steering and Scanning System. The Focussing System was an iron sheathed solenoid the Steering System was two sets of electromagnet placed perpendicular each other and the Scanning System was a set of alternating current electromagnet. The first Focussing System was designed to have 1 m focus distance for electron beam of 10 keV energy the second Focussing System was designed to have 1 m focus distance for electron beam of 1 MeV energy, the Steering System was designed to have 30o deflection angle for electron beam of 1 MeV energy and the Scanning System was designed to have 120 cm deflection distance and 20o deflection angle for electron beam of 1 MeV. Using these systems the 500 keV/10 mA Electron Beam Machine could be controlled. (author)

  5. The RHIC p-Carbon CNI Polarimeter Upgrade For The Beam Polarization And Intensity Measurements

    International Nuclear Information System (INIS)

    Proton polarization measurements in the AGS and RHIC (Relativistic Heavy Ion Collider at the beam energies 24-250 GeV) are based on proton-carbon and proton-proton elastic scattering in the Coulomb Nuclear Interference (CNI) region. Polarimeter operation in the scanning mode also gives polarization profile and beam intensity profile (beam emittance) measurements. Bunch by bunch emittance measurement is a very powerful tool for machine setup. Presently, the polarization and beam intensity profile measurements (in both vertical and horizontal planes) are restricted by the long target switching time and possible target destruction during this complicated motion. The RHIC polarimeters were operated near the limit of the counting rate for present silicon strip detectors. The ongoing polarimeter upgrade for the 2009 run will address all these problems. The upgrade should allow significant reduction of the polarization measurement errors by making feasible the complete polarization measurements, which includes polarization profiles in both the horizontal and vertical planes.

  6. Effect of Electron Beam Irradiation on the Tensile Properties of Carbon Nanotubes Sheets and Yarns

    Science.gov (United States)

    Williams, Tiffany S.; Miller, Sandi G.; Baker, James S.; McCorkle, Linda S.; Meador, Michael A.

    2013-01-01

    Carbon nanotube sheets and yarns were irradiated using electron beam (e-beam) energy to determine the effect of irradiation dose on the tensile properties. Results showed that a slight change in tensile strength occurred after irradiating as-received CNT sheets for 20 minutes, and a slight decrease in tensile strength as the irradiation time approached 90 minutes. On the other hand, the addition of small molecules to the CNT sheet surface had a greater effect on the tensile properties of e-beam irradiated CNT sheets. Some functionalized CNT sheets displayed up to a 57% increase in tensile strength following 90 minutes of e-beam exposure. In addition, as-received CNT yarns showed a significant increase in tensile strength as the irradiation time increased.

  7. Experimental study on fatigue crack propagation rate of RC beam strengthened with carbon fiber laminate

    Science.gov (United States)

    Huang, Peiyan; Liu, Guangwan; Guo, Xinyan; Huang, Man

    2008-11-01

    The experimental research on fatigue crack propagation rate of reinforced concrete (RC) beams strengthened with carbon fiber laminate (CFL) is carried out by MTS system in this paper. The experimental results show that, the main crack propagation on strengthened beam can be summarized into three phases: 1) fast propagation phase; 2) steady propagation and rest phase; 3) unsteady propagation phase. The phase 2-i.e. steady propagation and rest stage makes up about 95% of fatigue life of the strengthened beam. The propagation rate of the main crack, da/dN, in phase 2 can be described by Paris formula, and the constant C and m can be confirmed by the fatigue crack propagation experiments of the RC beams strengthened with CFL under three-point bending loads.

  8. Diffractive multi-beam surface micro-processing using 10 ps laser pulses

    International Nuclear Information System (INIS)

    A high repetition rate picosecond laser system is combined with a spatial light modulator (SLM) for diffractive multiple beam processing. The effect of the zero order beam is eliminated by adding a Fresnel zone lens (FZL) to defocus the un-diffracted beam at the processing plane. Chromatic dispersion, which is evident with a large bandwidth femtosecond pulses leading to the problem of distorted hole shape is eliminated due to the much narrower spectral bandwidth, ∼0.1 nm at 10 ps pulselength, resulting in highly uniform intensity spots, independent of diffraction angle. In addition, high-throughput processing is demonstrated by combining the high power laser output, 2.5 W at λ ∼ 1064 nm and fast repetition rate, f ∼ 20 kHz with P > 1.2 W diffracted into 25 parallel beams. This has the effect of creating an 'effective' repetition rate of 500 kHz without restrictive scan speeds.

  9. Carbon-ion beams induce production of an immune mediator protein, high mobility group box 1, at levels comparable with X-ray irradiation

    International Nuclear Information System (INIS)

    X-ray radiotherapy activates tumor antigen-specific T-cell responses, and increases in the serum levels of high mobility group box 1 (HMGB1) induced by X-ray irradiation play a pivotal role in activating anti-tumor immunity. Here, we examined whether carbon-ion beams, as well as X-rays, can induce HMGB1 release from human cancer cell lines. The study examined five human cancer cell lines: TE2, KYSE70, A549, NCI-H460 and WiDr. The proportion of cells surviving X- or carbon-ion beam irradiation was assessed in a clonogenic assay. The D10, the dose at which 10% of cells survive, was calculated using a linear–quadratic model. HMGB1 levels in the culture supernatants were assessed by an ELISA. The D10 dose for X-rays in TE2, KYSE70, A549, NCI-H460 and WiDr cells was 2.1, 6.7, 8.0, 4.8 and 7.1 Gy, respectively, whereas that for carbon-ion beams was 0.9, 2.5, 2.7, 1.8 and 3.5 Gy, respectively. X-rays and carbon-ion beams significantly increased HMGB1 levels in the culture supernatants of A549, NCI-H460 and WiDr cells at 72 h post-irradiation with a D10 dose. Furthermore, irradiation with X-rays or carbon-ion beams significantly increased HMGB1 levels in the culture supernatants of all five cell lines at 96 h post-irradiation. There was no significant difference in the amount of HMGB1 induced by X-rays and carbon-ion beams at any time-point (except at 96 h for NCI-H460 cells); thus we conclude that comparable levels of HMGB1 were detected after irradiation with iso-survival doses of X-rays and carbon-ion beams. (author)

  10. Clinical output factors for carbon-ion beams passing through polyethylene

    CERN Document Server

    Kanematsu, Nobuyuki; Ogata, Risa; Himukai, Takeshi

    2013-01-01

    Purpose: A recent study suggested that polyethylene (PE) range compensators would cause extra carbon-ion attenuation by 0.45%/cm due to limitations in water equivalence. The present study aims to assess its influence on tumor dose in carbon-ion radiotherapy. Methods: Carbon-ion radiation was modeled to be composed of primary carbon ions and secondary particles. For these components, tumor dose fraction and relative biological effectiveness (RBE) were estimated at a reference depth in the middle of spread-out Bragg peak. The PE effect was estimated for clinical carbon-ion beams and was partially tested by experiment. The two-component model was integrated into a treatment-planning system, with which the PE effect on tumor dose was investigated in two clinical cases. Results: The fluence and clinical attenuation coefficients for dose decrease per polyethylene thickness were estimated to be 0.1%-0.3%/cm and 0.2%-0.4%/cm, depending on energy and modulation of clinical carbon-ion beams. In the treatment-planning s...

  11. Nano-structural Modification of Amorphous Carbon Thin Films by Low-energy Electron Beam Irradiation

    Institute of Scientific and Technical Information of China (English)

    EijiIwamura; MasanoriYamaguchi

    2004-01-01

    A new approach using a low-energy electron beam radiation system was investigated to synthesize carbon hybrid structures in amorphous carbon thin films. Two types of amorphous carbon films, which were 15at% iron containing film and with column/inter-column structures, were deposited onto Si substrates by a sputtering technique and subsequently exposed to an electron shower of which the energy and dose rate were much smaller compared to an intense electron beam used in a transmission electron microscopy. As a result of the low-energy and low-dose electron irradiation process, graphitic structures formed in amorphous matrix at a relatively low temperature up to 450 K. Hybrid carbon thin films containing onion-like structures in an amorphous carbon matrix were synthesized by dynamic structural modification of iron containing amorphous carbon thin films. It was found that the graphitization progressed more in the electron irradiation than in annealing at 773K, and it was attributed to thermal and catalytic effects which are strongly related to grain growth of metal clusters. On the other hand, a reversal of TEM image contrast was observed in a-C films with column/inter-column structures. It is presumed that preferable graphitization occurred in the inter-column regions induced by electron irradiation.

  12. Nano-structural Modification of Amorphous Carbon Thin Films by Low-energy Electron Beam Irradiation

    Institute of Scientific and Technical Information of China (English)

    Eiji Iwamura; Masanori Yamaguchi

    2004-01-01

    A new approach using a low-energy electron beam radiation system was investigated to synthesize carbon hybrid structures in amorphous carbon thin films. Two types of amorphous carbon films, which were 15at% iron containing film and with column/inter-column structures, were deposited onto Si substrates by a sputtering technique and subsequently exposed to an electron shower of which the energy and dose rate were much smaller compared to an intense electron beam used in a transmission electron microscopy. As a result of the low-energy and low-dose electron irradiation process,graphitic structures formed in amorphous matrix at a relatively low temperature up to 450 K. Hybrid carbon thin films containing onion-like structures in an amorphous carbon matrix were synthesized by dynamic structural modification of iron containing amorphous carbon thin films. It was found that the graphitization progressed more in the electron irradiation than in annealing at 773K, and it was attributed to thermal and catalytic effects which are strongly related to grain growth of metal clusters. On the other hand, a reversal of TEM image contrast was observed in a-C films with column/inter-column structures. It is presumed that preferable graphitization occurred in the inter-column regions induced by electron irradiation.

  13. Radiological characteristics of MRI-based VIP polymer gel under carbon beam irradiation

    International Nuclear Information System (INIS)

    We study the radiological characteristics of VIP polymer gel dosimeters under carbon beam irradiation with energy of 135 and 290 AMeV. To evaluate dose response of VIP polymer gels, the transverse (or spin–spin) relaxation rate R2 of the dosimeters measured by magnetic resonance imaging (MRI) as a function of linear energy transfer (LET), rather than penetration depth, as is usually done in previous reports. LET is evaluated by use of the particle transport simulation code PHITS. Our results reveal that the dose response decreases with increasing dose-averaged LET and that the dose response–LET relation also varies with incident carbon beam energy. The latter can be explained by taking into account the contribution from fragmentation products. - Highlights: • We study the radiological characteristics of VIP gel dosimeters under carbon beam irradiation. • Linear energy transfer dependence was evaluated and discussed with simulation code PHITS. • Contribution from secondly ion can explain results with different incident beam energy

  14. Establishment of the method for profile evaluation in matter using the therapeutic carbon pencil beam

    International Nuclear Information System (INIS)

    The scanning irradiation of the pencil beam is superior in comparison to the conventional extended-field irradiation in dose concentration. The carbon pencil beam spreads its profile in matter. The factors that cause the profile change are the nuclear fragmentation reactions and the multiple Coulomb scatterings. The fragmentation reaction is a type of nuclear reactions, where the high-energy incident particles interact with target nuclei and fragment the incident particles themselves or the target nucleus. In order to improve the accuracy of the treatment planning for the carbon beam, it is necessary to evaluate quantitatively the effect of the nuclear fragmentation reactions. The objective of this study is to establish the evaluation method for the carbon pencil beam profile in matter by selectively acquiring the nuclear fragmentation reactions and the multiple Coulomb scattering. This experiment was proposed to carry out in three years. Events with the nuclear fragmentation reactions and the multiple Coulomb scatterings were separately identified by a dedicated detector devised by our group. Profiles of these events were successfully measured. (author)

  15. Rationale for carbon ion therapy in high-grade glioma based on a review and a meta-analysis of neutron beam trials

    International Nuclear Information System (INIS)

    Purpose: The standard treatment of high-grade glioma is still unsatisfactory: the 2-year survival after radiotherapy being only 10-25%. A high linear energy transfer (Let) ionising radiotherapy has been used to overcome tumour radioresistance. An overview of the field is needed to justify future prospective controlled studies on carbon ion therapy. Materials and methods: A meta-analysis of clinical trials on neutron beam therapy and a literature review of clinical investigations on light ion use in high-grade glioma were carried out. Results: Four randomized controlled trials on neutron beam therapy were retained. The meta-analysis showed a non-significant 6% increase of two-year mortality (Relative risk [R.R.] 1.06 [0.97-1.15]) in comparison with photon therapy. Two phase I/II trials on carbon and neon ion therapy reported for glioblastoma 10% and 31% two-year overall survivals and 13.9 and 19.0 months median survivals, respectively. Conclusion: This meta-analysis suggests that neutron beam therapy does not improve the survival of high-grade glioma patients while there is no definitive conclusion yet regarding carbon therapy. The ballistic accuracy and the improved biological efficacy of carbon ions renew the interest in prospective clinical trials on particle beam radiotherapy of glioma and let us expect favourable effects of dose escalation on patients survival. (author)

  16. Distribution of hydrogen peroxide-dependent reaction in a gelatin sample irradiated by carbon ion beam

    International Nuclear Information System (INIS)

    We investigated the amount and distribution of hydrogen peroxide (H2O2) generated in a solid gelatin sample irradiated by heavy ion (carbon) beam. We irradiated the gelatin sample, which contained a nitroxyl radical (4-hydroxy-2,2,6,6-tetramethylpiperidine-N-oxyl, TEMPOL), with a 290-MeV/nucleon carbon beam (-128 Gy). To verify the distribution of H2O2 generation in the irradiated sample, we employed both electron paramagnetic resonance (EPR) spectroscopic and magnetic resonance (MR) imaging methods based on H2O2-dependent paramagnetic loss of TEMPOL. We obtained a distribution profile of the H2O2-dependent reaction in the gelatin sample when we irradiated gelatin samples with carbon beams with several different linear energy transfer (LET) values. Because the profiles of oxygen consumption in the gelatin sample measured by L-band EPR oxymetry and of the H2O2-dependent reaction have almost the same shape, the profile of the H2O2-dependent reaction can be used as an estimation of the profile of the generation of H2O2. The H2O2 profile in one intact gelatin sample scanned by 7-tesla MR imaging showed a similar shape as a result of the EPR experiment. We obtained several hundreds of micromolars of H2O2 generated in a gelatin sample irradiated by carbon beam when 200 Gy was given at the surface of the sample. H2O2 distribution was almost flat, with only a slight peak just before the end of the beam. (author)

  17. Ultra-low-energy (<10 eV/u) ion beam bombardment effect on naked DNA

    Energy Technology Data Exchange (ETDEWEB)

    Thopan, P. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thongkumkoon, P. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Department of Biology, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Prakrajang, K. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Faculty of Science, Maejo University, Chiang Mai 50290 (Thailand); Suwannakachorn, D. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Yu, L.D., E-mail: yuld@thep-center.org [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thailand Center of Excellence in Physics, Commission on Higher Education, 328 Si Ayutthaya Road, Bangkok 10400 (Thailand)

    2014-05-01

    Highlights: • Decelerated ultra-low energy ion beam bombarded naked DNA. • DNA form change induced by ion bombardment was investigated. • N-ion bombardment at 32 eV induced DNA single and double strand breaks. • Ar-ion bombardment at a-few-hundreds eV induced DNA single strand break. - Abstract: Since ion energy deposition in the ion-bombarded materials dominantly occurs in the low-energy range, it is very interesting to know effects from ultra-low-energy ion interaction with DNA for understanding ion-beam-induced genetic mutation. Tens-keV Ar- and N-ion beams were decelerated to ultra-low energy ranging from 20 to 100 eV, or only a few to 10 eV/u, to bombard naked plasmid DNA. The bombarded DNA was analyzed using gel electrophoresis for DNA form changes. The original DNA supercoiled form was found to change to relaxed and linear forms, indicating single or double strand breaks after bombarded by tens-eV ion beam. N-ion beam was found more effective in inducing DNA change and mutation than Ar-ion beam. The study demonstrated that the ion bombardment with energy as low as several-tens eV was able to break DNA strands and thus potentially to cause genetic modification of biological cells. The experimental results were discussed in terms of direct atomic collision between the ions and DNA atoms.

  18. Deposition of diamond like carbon films by using a single ion gun with varying beam source

    Institute of Scientific and Technical Information of China (English)

    JIANG Jin-qiu; Chen Zhu-ping

    2001-01-01

    Diamond like carbon films have been successfully deposited on the steel substrate, by using a single ion gun with varying beam source. The films may appear blue, yellow and transparent in color, which was found related to contaminants from the sample holder and could be avoided. The thickness of the films ranges from tens up to 200 nanometers, and the hardness is in the range 20 to 30 GPa. Raman analytical results reveal the films are in amorphous structure. The effects of different beam source on the films structure are further discussed.

  19. Raman shift on n-doped amorphous carbon thin films grown by electron beam evaporation

    Energy Technology Data Exchange (ETDEWEB)

    Rebollo P., B. [Departamento de Fisica, Pontificia Universidad Catolica de Rio de Janeiro (Brazil); Facultad de Ciencias Fisico-Matematicas, Benemerita Universidad Autonoma de Puebla (Mexico); Freire L., F. Jr. [Departamento de Fisica, Pontificia Universidad Catolica de Rio de Janeiro (Brazil); Lozada M., R.; Palomino M., R. [Facultad de Ciencias Fisico-Matematicas, Benemerita Universidad Autonoma de Puebla (Mexico); Jimenez S., S. [Centro de Investigacion y de Estudios Avanzados del IPN, Laboratorio de Investigacion en Materiales, Queretaro (Mexico); Zelaya A., O. [Centro de Investigacion y de Estudios Avanzados del IPN, Departamento de Fisica, CINVESTAV-IPN, P.O. Box 14-740, Mexico 07360 D.F. (Mexico)

    2007-04-15

    The structural properties of carbon thin films synthesized under an atmosphere of nitrogen by means of electron beam evaporation were studied by Raman scattering spectroscopy. The electron beam evaporation technique is an important alternative to grown layers of this material with interesting structural properties. The observed shift of the Raman G band shows that the structure of the films tends to become more graphitic upon the increase of the deposition time. (copyright 2007 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  20. Optical and Scratch Resistant Properties of Diamondlike Carbon Films Deposited with Single and Dual Ion Beams

    Science.gov (United States)

    Kussmaul, Michael T.; Bogdanski, Michael S.; Banks, Bruce A.; Mirtich, Michael J.

    1993-01-01

    Amorphous diamond-like carbon (DLC) films were deposited using both single and dual ion beam techniques utilizing filament and hollow cathode ion sources. Continuous DLC films up to 3000 A thick were deposited on fused quartz plates. Ion beam process parameters were varied in an effort to create hard, clear films. Total DLC film absorption over visible wavelengths was obtained using a Perkin-Elmer spectrophotometer. An ellipsometer, with an Ar-He laser (wavelength 6328 A) was used to determine index of refraction for the DLC films. Scratch resistance, frictional, and adherence properties were determined for select films. Applications for these films range from military to the ophthalmic industries.

  1. Electron-beam heat treatment of thin band of low-carbon steel

    International Nuclear Information System (INIS)

    Using the methods of raster electron microscopy, X-ray structural and chemical analysis and also X-ray microanalysis, the change was studied in the mechanical properies of a band made of low-carbon steel 08 kp that takes place after electron-beam heat treatment. It has been shown that the above change is due to a specific character of the α reversible γ phase transition. After electron-beam treatment under optimum conditions, the properties of the band made of steel 08 kp and 0.15 mm thick (plasticity, ultimate strength, etc.) are similar to those obtained using the conventional procedures (annealing and skin pass rolling)

  2. The influence of lateral beam profile modifications in scanned proton and carbon ion therapy: a Monte Carlo study

    CERN Document Server

    Parodi, K; Kraemer, M; Sommerer, F; Naumann, J; Mairani, A; Brons, S

    2010-01-01

    Scanned ion beam delivery promises superior flexibility and accuracy for highly conformal tumour therapy in comparison to the usage of passive beam shaping systems. The attainable precision demands correct overlapping of the pencil-like beams which build up the entire dose distribution in the treatment field. In particular, improper dose application due to deviations of the lateral beam profiles from the nominal planning conditions must be prevented via appropriate beam monitoring in the beamline, prior to the entrance in the patient. To assess the necessary tolerance thresholds of the beam monitoring system at the Heidelberg Ion Beam Therapy Center, Germany, this study has investigated several worst-case scenarios for a sensitive treatment plan, namely scanned proton and carbon ion delivery to a small target volume at a shallow depth. Deviations from the nominal lateral beam profiles were simulated, which may occur because of misaligned elements or changes of the beam optic in the beamline. Data have been an...

  3. Compilation of erosion yields of metal-doped carbon materials by deuterium impact from ion beam and low temperature plasma

    Energy Technology Data Exchange (ETDEWEB)

    Balden, M., E-mail: Martin.Balden@ipp.mpg.de [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, 85748 Garching (Germany); Starke, P. [Lehrstuhl fuer Experimentelle Plasmaphysik, Institut fuer Physik, Universitaet Augsburg, D-86135 Augsburg (Germany); Garcia-Rosales, C. [CEIT and Tecnun (University of Navarra), E-20018 San Sebastian (Spain); Adelhelm, C.; Sauter, P.A. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, 85748 Garching (Germany); Lopez-Galilea, I.; Ordas, N. [CEIT and Tecnun (University of Navarra), E-20018 San Sebastian (Spain); Fernandez, J.M. Ramos; Escandell, M. Martinez [Departamento de Quimica Inorganica, University of Alicante, E-03690 Alicante (Spain)

    2011-10-01

    The erosion yield by deuterium impact was determined for various doped carbon-based materials. Ion beam bombardment with 30 and 200 eV at elevated temperatures (600-850 K) and low temperature plasma exposure with 30 eV ion energy ({approx}7 x 10{sup 20} ions/m{sup 2}s) and about 170 times higher thermal atomic deuterium flux at 300 K and 630 K were performed. The total yield of fine-grain graphites doped with 4 at.% Ti and Zr is reduced by a factor of 4 for 30 and 200 eV D impact at elevated temperatures at D fluences above 10{sup 24} m{sup -2} compared to undoped graphite. Extensive carbide particle loss can be excluded up to fluences of {approx}10{sup 25} m{sup -2}.

  4. Stoichiometric carbon nitride synthesized by ion beam sputtering and post nitrogen ion implantation

    International Nuclear Information System (INIS)

    Full text: Carbon nitride films have been deposited on Si (100) by ion beam sputtering a vitreous graphite target with nitrogen and argon ions with and without concurrent N2 ion bombardment at room temperature. The sputtering beam energy was 1000 eV and the assisted beam energy was 300 eV with ion / atom arrival ratio ranging from 0.5 to 5. The carbon nitride films were deposited both as single layer directly on silicon substrate and as multilayer between two layers of stoichiometric amorphous silicon nitride and polycrystalline titanium nitride. The deposited films were implanted ex-situ with 30 keV nitrogen ions with various doses ranging from 1E17 to 4E17 ions.cm-2 and 2 GeV xenon ion with a dose of 1E12 ions.cm-2 . The nitrogen concentration of the films was measured with Rutherford Backscattering (RBS), Secondary Neutral Mass Spectrometry (SNMS) and Parallel Electron Energy Loss Spectroscopy (PEELS). The nitrogen concentration for as deposited sample was 34 at% and stoichiometric carbon nitride C3N4 was achieved by post nitrogen implantation of the multi-layered films. Post bombardment of single layer carbon nitride films lead to reduction in the total nitrogen concentration. Carbon K edge structure obtained from PEELS analysis suggested that the amorphous C3N4 matrix was predominantly sp2 bonded. This was confirmed by Fourier Transforrn Infra-Red Spectroscopy (FTIR) analysis of the single CN layer which showed the nitrogen was mostly bonded with carbon in nitrile (C≡N) and imine (C=N) groups. The microstructure of the film was determined by Transmission Electron Microscopy (TEM) which indicated that the films were amorphous

  5. Off-line production of intense 7,10Be+ beams

    International Nuclear Information System (INIS)

    7Be and 10Be were produced by 590 MeV proton bombardment of a graphite target at PSI. Parts of this graphite target were transferred into an ISOLDE target and ion source unit and ionized with the ISOLDE resonance ionization laser ion source. Thus intense radioactive ion beams of 300 nA of 7,10Be+ were produced off-line

  6. Charge equilibrium of a laser-generated carbon-ion beam in warm dense matter

    International Nuclear Information System (INIS)

    Using ion carbon beams generated by high intensity short pulse lasers we perform measurements of single shot mean charge equilibration in cold or isochorically heated solid density aluminum matter. We demonstrate that plasma effects in such matter heated up to 1 eV do not significantly impact the equilibration of carbon ions with energies 0.045-0.5 MeV/nucleon. Furthermore, these measurements allow for a first evaluation of semiempirical formulas or ab initio models that are being used to predict the mean of the equilibrium charge state distribution for light ions passing through warm dense matter. (authors)

  7. 2002 Monthly Carbon Dioxide Emissions from Mexico at a 10x10k Spatial Resolution

    Science.gov (United States)

    Mendoza, D. L.; Gurney, K. R.; Geethakumar, S.; Zhou, Y.; Sahni, N.

    2009-12-01

    The contribution of fossil fuel CO2 emissions to the total measured amount of CO2 in the Earth’s atmosphere remains an important component of carbon cycle science, particularly as efforts to understand the net exchange of carbon at the surface move to smaller scales. In order to reduce the uncertainty of this flux, researchers led by Purdue University have built a high-resolution fossil fuel CO2 flux inventory for the United States, called “Vulcan”. The Vulcan inventory quantifies emissions for the United States at 10km resolution every hour for the year 2002 and can be seen as a key component of a national assessment and verification system for greenhouse gas emissions and emissions mitigation. As part of the North American Carbon Project, the 2002 carbon dioxide emissions from Mexico are presented at the monthly temporal and municipality spatial scale. Mexico is of particular importance because of the scientific integration under the North American Carbon Program. Furthermore, Mexico has seen a notable growth in its population as well as migration toward urban centers and increasing energy requirements due in part to industrial intensification. The native resolution of the emissions is geolocated (lat/lon) for point sources, such as power plants, airports, and large industry. The emissions are estimated at the municipality level for residential and commercial sources, and allocated to roads for the mobile transport sector. Data sources include the National Emissions Inventory (NEI), Commission for Environmental Cooperation (CEC), and Carbon Monitoring for Action (CARMA). CO2 emissions are calculated from the 1999 NEI data by converting CO emissions using sector and process-dependent emission factors, and is scaled up to 2002 using statistics obtained from the Carbon Dioxide Information Analysis Center CDIAC. CEC and CARMA data, which encompass power plant emissions, are already in units of CO2. Emissions are regridded to 10x10k and 0.1x0.1 deg grids to

  8. Polarimetry diagnostic on OMEGA EP using a 10-ps, 263-nm probe beam

    Energy Technology Data Exchange (ETDEWEB)

    Davies, A., E-mail: adavies@lle.rochester.edu; Haberberger, D.; Boni, R.; Ivancic, S.; Brown, R.; Froula, D. H. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623 (United States)

    2014-11-15

    A polarimetry diagnostic was built and characterized for magnetic-field measurements in laser-plasma experiments on the OMEGA EP laser. This diagnostic was built into the existing 4ω (263-nm) probe system that employs a 10-ps laser pulse collected with an f/4 imaging system. The diagnostic measures the rotation of the probe beam's polarization. The polarimeter uses a Wollaston prism to split the probe beam into orthogonal polarization components. Spatially localized intensity variations between images indicate polarization rotation. Magnetic fields can be calculated by combining the polarimetry data with the measured plasma density profile obtained from angular filter refractometry.

  9. Production of megavolt neutron beams with relative energy spread of ∼5x10-4

    International Nuclear Information System (INIS)

    A method for production of megavolt neutron beams with relative energy spread of ∼ 5x10-4 based on using electrostatic accelerator and a foilless gas target permitting to realize continuous and easily controlled reproduction of working substance (acetone, heavy water) is described. Differential pumping of vapors of working substance by freezing in refrigerators cooled by liquid nitrogen is used in the target. Technique for using neutron beams from the 12C(d, n) reaction for measuring total cross sections of neutron interaction with nuclei and differential cross sections of elastic scattering is developed

  10. Sub-10 nm structures written in ultra-thin HSQ resist layers, using Electron Beam Lithography

    OpenAIRE

    Grigorescu, A.E.; Van der Krogt, M.; Hagen, C.W.

    2007-01-01

    Isolated dots and lines with 6 nm width were written in 20 nm thick Hydrogen silsesquioxane (HSQ) layers on silicon substrates, using 100 keV electron beam lithography. The main factors that might limit the resolution, i.e. beam size, writing strategy, resist material, electron dose, development process, are discussed. We demonstrate that, by adjusting the development process, a very high resolution can be obtained. We report the achievement of 7 nm lines at a 20 nm pitch written in a 10 nm t...

  11. An EXAFS spectrometer on beam line 10B at the Photon Factory

    International Nuclear Information System (INIS)

    An EXAFS spectrometer installed on the beam line 10B at the Photon Factory is designed to cover the photon energy between 4 and 30 keV. Utilizing either a channel-cut or two flat silicon crystals as a monochromator, a beam intensity between 108 and 109 photons/sec is obtained at 9 keV with a resolution of 1 eV. The performance of the spectrometer, such as a signal-to-noise ratio or an energy resolution is demonstrated with examples of K edge absorption spectra of bromine, germanium, gallium arsenide, and zinc selenide. (author)

  12. Use of the small proportional counter for carbon 14 measurement in 10 milligram carbon samples

    International Nuclear Information System (INIS)

    Ten years ago, the measurement of C-14/C-12 ratios in 10 milligram carbon samples seemed to be technically out of reach. However, two developments that make this goal possible have recently occurred: the first is an entirely new mass-spectrometric separation of C-14 and C-12 ions and their subsequent estimation by counting, while the second is simply the extension of conventional proportional counter operation (using CO2 as counter gas) to very small size carbon samples. The first method is very fast, precise, and capable of treating samples of even sub-milligram size, but requires an expensive installation. The second method is slow (counting times of two months or more are necessary), can probably be made sufficiently precise to handle most problems, works down to sample sizes of 10 mg carbon, and is relatively inexpensive, especially to install in already existing radiocarbon laboratories. It is this second method and its implications that are discussed in the present paper

  13. Tribological properties of ion beam deposited diamond-like carbon film on silicon nitride

    International Nuclear Information System (INIS)

    The present article reports on the physical characterization and tribological properties of diamond-like carbon (DLC) films deposited on structural Si3N4 substrates. The films were deposited by the direct ion beam deposition technique. The ion beam was produced by plasma discharge of pre-mixed methane and hydrogen gas in a Kaufman-type ion source. The deposited films were found to be amorphous and contained about 70% carbon and 30% hydrogen. The friction coefficient of an uncoated Si3N4 ball on a DLC coated Si3N4 disc starts at about 0.2, then decreases rapidly to 0.1-0.15 with increasing sliding distance. Increasing humidity results in a slight increase in friction coefficient, but a significant decrease in wear factor. The wear factor for the tests at ≅60% rh (relative humidity) are about an order of magnitude smaller than the tests at 3% rh. (orig.)

  14. Radiological characteristics of MRI-based VIP polymer gel under carbon beam irradiation

    Science.gov (United States)

    Maeyama, T.; Fukunishi, N.; Ishikawa, K. L.; Furuta, T.; Fukasaku, K.; Takagi, S.; Noda, S.; Himeno, R.; Fukuda, S.

    2015-02-01

    We study the radiological characteristics of VIP polymer gel dosimeters under carbon beam irradiation with energy of 135 and 290 AMeV. To evaluate dose response of VIP polymer gels, the transverse (or spin-spin) relaxation rate R2 of the dosimeters measured by magnetic resonance imaging (MRI) as a function of linear energy transfer (LET), rather than penetration depth, as is usually done in previous reports. LET is evaluated by use of the particle transport simulation code PHITS. Our results reveal that the dose response decreases with increasing dose-averaged LET and that the dose response-LET relation also varies with incident carbon beam energy. The latter can be explained by taking into account the contribution from fragmentation products.

  15. Development of 120 keV 10 MW neutral beam teststand

    International Nuclear Information System (INIS)

    This is a report of design and construction of 120 keV, 10 MW Neutral Beam Test Stand (10 MW NBTS) which has been prepared for the development of NB Injector on R-project in the 1981 to 1982 fiscal year. The Test Stand is designed to simulate NBI on the project and the aim is test for the performance of many components and the over all performance of beam line. A design of the beam line (which is composed of a neutralizer cell, a 180 deg deflection magnet, calorimeter, and ion dump, etc.), 1/4 size ion source, power supply system, and sequence and control are described, and the test results are also given briefly. Main features of the NBTS are as follows: (1) A powerful ion source of 120 keV, 75 A for 1 sec, (2) Gate Turn Off (G.T.O.) accel power supply system of 120 kV, 10 MW, in which all the components are fabricated by the solid-state elements, (3) highspeed open-type cryocondensation pump for the vacuum system. Test results of each component are compared with the design value of them. Overall test including the beam extraction of up to 120 keV, ∼ 20 A for 1 sec is satisfactorily completed by applying 1/4 size model ion source. (author)

  16. Consumption of carbon fiber plates in the reinforced concrete beams strengthened with CFPs

    Institute of Scientific and Technical Information of China (English)

    BU Liangtao; SONG Li; SHI Chuxian

    2007-01-01

    Four-point bending flexural tests were conducted to one full-size reinforced concrete (RC) beam and three full-size RC beams strengthened with carbon fiber plates (CFPs).The experimental results showed that the consumption of CFP had significant effects on failure modes and the flexural capacity.An analytical procedure,based on the limit failure ode and ductility,was presented to predict the applied area of CFP.An analytical program,based on Smith-Teng model and Cheng-Teng model,was provided to calculate the bonding length of CFP.The test results are used to validate the proposed procedure.The results are also applied to the design and construction of RC beam strengthened with CFP.

  17. Characterization of focused beam of desktop 10-Hz capillary-discharge 46.9-nm laser

    Science.gov (United States)

    Vyšin, Ludek; Burian, Tomás; Chalupský, Jaromír; Grisham, Michael; Hájková, Vera; Heinbuch, Scott; Jakubczak, Krzysztof; Martz, Dale; Mocek, Tomás; Pira, Peter; Polan, Jirí; Rocca, Jorge J.; Rus, Bedrich; Sobota, Jaroslav; Juha, Libor

    2009-05-01

    The desktop capillary-discharge Ne-like Ar laser (CDL) providing 10-μJ nanosecond pulses of coherent 46.9-nm radiation with a repetition rate up to 12 Hz was developed and built at the Colorado State University in Fort Collins and then installed in Prague. The beam of the laser was focused by a spherical mirror covered with Si/Sc multilayer coating onto the surface of poly(methyl methacrylate) - PMMA. Interaction parameters vary by changing the distance between sample surface and beam focus. The samples were exposed to various numbers of shots. Analysis of damaged PMMA by atomic force (AFM) and Nomarski (DIC - differential interference contrast) microscopes allows not only to determine the key characteristics of the focused beam (e.g. Rayleigh's parameter, focal spot diameter, tight focus position, etc.) but also to investigate mechanisms of the radiation-induced erosion processes.

  18. Electrochemical impedance spectroscopy on nanostructured carbon electrodes grown by supersonic cluster beam deposition

    Energy Technology Data Exchange (ETDEWEB)

    Bettini, Luca Giacomo; Bardizza, Giorgio; Podesta, Alessandro; Milani, Paolo; Piseri, Paolo, E-mail: piseri@mi.infn.it [Universita degli Studi di Milano, Dipartimento di Fisica and CIMaINa (Italy)

    2013-02-15

    Nanostructured porous films of carbon with density of about 0.5 g/cm{sup 3} and 200 nm thickness were deposited at room temperature by supersonic cluster beam deposition (SCBD) from carbon clusters formed in the gas phase. Carbon film surface topography, determined by atomic force microscopy, reveals a surface roughness of 16 nm and a granular morphology arising from the low kinetic energy ballistic deposition regime. The material is characterized by a highly disordered carbon structure with predominant sp2 hybridization as evidenced by Raman spectroscopy. The interface properties of nanostructured carbon electrodes were investigated by cyclic voltammetry and electrochemical impedance spectroscopy employing KOH 1 M solution as aqueous electrolyte. An increase of the double layer capacitance is observed when the electrodes are heat treated in air or when a nanostructured nickel layer deposited by SCBD on top of a sputter deposited film of the same metal is employed as a current collector instead of a plain metallic film. This enhancement is consistent with an improved charge injection in the active material and is ascribed to the modification of the electrical contact at the interface between the carbon and the metal current collector. Specific capacitance values up to 120 F/g have been measured for the electrodes with nanostructured metal/carbon interface.

  19. Mutagenic effects of carbon ion beam irradiations on dry Lotus japonicus seeds

    Science.gov (United States)

    Luo, Shanwei; Zhou, Libin; Li, Wenjian; Du, Yan; Yu, Lixia; Feng, Hui; Mu, Jinhu; Chen, Yuze

    2016-09-01

    Carbon ion beam irradiation is a powerful method for creating mutants and has been used in crop breeding more and more. To investigate the effects of carbon ion beams on Lotus japonicus, dry seeds were irradiated by 80 MeV/u carbon ion beam at dosages of 0, 100, 200, 300, 400, 500 and 600 Gy. The germination rate, survival rate and root length of M1 populations were explored and the dose of 400 Gy was selected as the median lethal dose (LD50) for a large-scale mutant screening. Among 2472 M2 plants, 127 morphological mutants including leaf, stem, flower and fruit phenotypic variation were found, and the mutation frequency was approximately 5.14%. Inter simple sequence repeat (ISSR) assays were utilized to investigate the DNA polymorphism between seven mutants and eight plants without phenotypic variation from M2 populations. No remarkable differences were detected between these two groups, and the total polymorphic rate was 0.567%.

  20. 8 and 10 MeV electron beam small field profiles through Fricke xylenol gel dosimeter

    International Nuclear Information System (INIS)

    The dose distribution evaluation along of an ionizing radiation field central axis is one of the factors that contribute to the absorbed dose accuracy in the target volume. This distribution can show specific characteristics of an electron beam as the parameters penumbra, symmetry and homogeneity (flatness), which can be depicted from beam profiles. In this work was evaluated the behavior of these parameters as a function of the electron beam energy and the field size. The Fricke Xylenol Gel (FXG) is a chemical dosimeter that has an effective atomic number of 7.75 and density of 1.05 g/cm3, near to those of soft tissue. For beam profile analysis were used: the dosimeters FXG and the ionization chamber (IC), source skin distance of 100 cm, square and circular small field sizes configurations and 8 and 10 MeV electron energies. From the obtained results one could verify that the penumbra values were higher for the higher energy and larger field sizes, while the symmetry and flatness presented variation only with the energy, being this variation for flatness almost insignificant. The parameter results for both dosimeters, present similar behaviors and values in agreement with the established tolerances. Through these results one can conclude that the FXG can be applied as dosimeter in the evaluation of parameters that characterizes clinical electron beams for small field sizes. (author)

  1. Tilting of carbon encapsulated metallic nanocolumns in carbon-nickel nanocomposite films by ion beam assisted deposition

    Energy Technology Data Exchange (ETDEWEB)

    Krause, Matthias [Helmholtz-Zentrum Dresden-Rossendorf, PF-510119, 01314 Dresden (Germany); Technische Universitaet Dresden, D-01062 Dresden (Germany); Muecklich, Arndt; Zschornak, Matthias; Wintz, Sebastian; Gemming, Sibylle; Abrasonis, Gintautas [Helmholtz-Zentrum Dresden-Rossendorf, PF-510119, 01314 Dresden (Germany); Oates, Thomas W. H. [Leibniz-Institut fuer Analytische Wissenschaft, ISAS e.V., Albert-Einstein-Str. 9, 12489 Berlin (Germany); Luis Endrino, Jose [Surfaces and Coatings Department, Instituto de Ciencia de Materiales de Madrid, c/Sor Juana Ines de la Cruz 3, Cantoblanco, 28049 Madrid (Spain); Baehtz, Carsten; Shalimov, Artem [Helmholtz-Zentrum Dresden-Rossendorf, PF-510119, 01314 Dresden (Germany); Rossendorf Beamline, European Synchrotron Radiation Facility, F-38043 Grenoble (France)

    2012-07-30

    The influence of assisting low-energy ({approx}50-100 eV) ion irradiation effects on the morphology of C:Ni ({approx}15 at. %) nanocomposite films during ion beam assisted deposition (IBAD) is investigated. It is shown that IBAD promotes the columnar growth of carbon encapsulated metallic nanoparticles. The momentum transfer from assisting ions results in tilting of the columns in relation to the growing film surface. Complex secondary structures are obtained, in which a significant part of the columns grows under local epitaxy via the junction of sequentially deposited thin film fractions. The influence of such anisotropic film morphology on the optical properties is highlighted.

  2. Focused-electron-beam-induced processing (FEBIP) for emerging applications in carbon nanoelectronics

    International Nuclear Information System (INIS)

    Focused-electron-beam-induced processing (FEBIP), a resist-free additive nanomanufacturing technique, is an actively researched method for ''direct-write'' processing of a wide range of structural and functional nanomaterials, with high degree of spatial and time-domain control. This article attempts to critically assess the FEBIP capabilities and unique value proposition in the context of processing of electronics materials, with a particular emphasis on emerging carbon (i.e., based on graphene and carbon nanotubes) devices and interconnect structures. One of the major hurdles in advancing the carbon-based electronic materials and device fabrication is a disjoint nature of various processing steps involved in making a functional device from the precursor graphene/CNT materials. Not only this multi-step sequence severely limits the throughput and increases the cost, but also dramatically reduces the processing reproducibility and negatively impacts the quality because of possible between-the-step contamination, especially for impurity-susceptible materials such as graphene. The FEBIP provides a unique opportunity to address many challenges of carbon nanoelectronics, especially when it is employed as part of an integrated processing environment based on multiple ''beams'' of energetic particles, including electrons, photons, and molecules. This avenue is promising from the applications' prospective, as such a multi-functional (electron/photon/molecule beam) enables one to define shapes (patterning), form structures (deposition/etching), and modify (cleaning/doping/annealing) properties with locally resolved control on nanoscale using the same tool without ever changing the processing environment. It thus will have a direct positive impact on enhancing functionality, improving quality and reducing fabrication costs for electronic devices, based on both conventional CMOS and emerging carbon (CNT/graphene) materials. (orig.)

  3. Application of Al2O3:C+fibre dosimeters for 290 MeV/n carbon therapeutic beam dosimetry

    International Nuclear Information System (INIS)

    The capability of radioluminescence (RL) dosimeters composed of carbon-doped aluminium oxide (Al2O3:C) detectors+optical fibre has been verified for absorbed dose-rate measurements during carbon radiotherapy. The RL signals from two separate Al2O3:C detectors (single crystal 'CG' and droplet 'P1') have been systematically measured and compared along the Bragg-curve and Spread-Out Bragg-Peak of 290 MeV/n carbon beams in the water. The absorbed dose response was assessed for the range of 0.5–10 Gy. For doses up to 6 Gy, we observed a linear response for both types of detectors, while for higher doses CG presented a more prominent supraliearity than P1. The RL response for low-LET protons in the entrance from the curve was found to closely resemble that observed for a clinical 6 MV X-ray beam, while it was found that P1 has a better agreement with the reference data from standard ionization chamber than CG. We observed a significant decrease in luminescence efficiency with LET in the Bragg peak region. The Al2O3:C RL luminescence efficiency differs from Al2O3:C OSL results, which implies that the signal can be corrected for LET dependency to match the correct SOBP and Bragg Peak. - Highlights: • Radioluminescence (RL) real time signal from Al2O3:C+fibre probes. • Irradiations with 290 MeV/n Carbon. • Two types of detectors were tested: droplet and single crystal. • Luminescence efficiencies for each probe were compared with 6 MV photons. • Bragg Peak and SOBP are obtained. • Luminescence efficiencies for Optically Stimulated Luminescence (OSL) and RL are compared for Al2O3:C

  4. Reactions with a 10Be beam to study the one-neutron halo nucleus 11Be

    Science.gov (United States)

    Jones, K. L.

    2016-07-01

    Halo nuclei are excellent examples of few-body systems consisting of a core and weakly-bound halo nucleons. Where there is only one nucleon in the halo, as in 11Be, the many-body problem can be reduced to a two-body problem. The contribution of the 1s1/2 orbital to the ground state configuration in 11Be, characterized by the spectroscopic factor, S, has been extracted from direct reaction data by many groups over the past five decades with discrepant results. An experiment was performed at the Holifield Radioactive Ion Beam Facility using a 10Be primary beam at four different energies with the goal of resolving the discrepancy through a consistent analysis of elastic, inelastic, and transfer channels. Faddeev-type calculations, released after the publication of the experimental results, show that dynamic core excitation in the transfer process can lead to reduced differential cross sections at higher beam energies. This reduction would lead to the extraction of decreasing values of S with increasing beam energy. A 10Be(d,p) measurement at Ed greater than 25 MeV is necessary to investigate the effects of core excitation in the reaction.

  5. Irradiation of an IBL stave in a 10MeV beta beam

    CERN Document Server

    Bilbao de Mendizabal, J; The ATLAS collaboration; Nuiry, FX; Seez, W

    2013-01-01

    The new IBL detector (Insertable B-Layer), due to be integrated into the ATLAS detector as the closest Pixel layer to the beam pipe during the first LHC long-shutdown (2013), is composed of fourteen stave sub-assemblies. These staves have a triangular cross section carbon foam core, sandwiched between a triangular carbon fibre plate (omega) and a flat top plate (faceplate) onto which the silicon detector modules and services are glued. The assembly is strongly dependant on glue and thermal grease interfaces; high density amorphous materials prone to degradation under high radiation doses. In order to evaluate the mechanical stability and integrity of one of these staves it was decided to impose a very high radiation dose upon it, representative of the full dose IBL will receive in its life-cycle. Because of the lack of availability of proton beams - the closest approximation to the radiation received in operation - with a large enough sweep area and dose it was decided to undertake the experiment using an ind...

  6. Reinforced concrete beams strengthened with carbon fiber reinforced polymer by friction hybrid bond technique: Experimental investigation

    International Nuclear Information System (INIS)

    Highlights: • Friction Hybrid Bonded FRP Technique is conducted to strengthen RC beams. • Six specimens with different reinforced methods were tested. • The strengthened effects of different strengthening methods were discussed. • The results obtained from the FEA and experiments are agreed very well. - Abstract: Carbon fiber reinforced polymer (CFRP) can be used to strengthen the reinforced concrete (RC) beams. But premature debonding is the main failure model in ordinary bond technique, and the strengthening effect is limited. In order to improve bonding and restricting sliding displacement, Friction Hybrid Bonded FRP Technique (FHB-FRP) is developed. Six simple-span RC specimen beams with different strengthened methods were tested in four-point bending. The experiment results indicate that FRP debonding can be effectively prevented by the FHB-FRP strengthened beam. The ultimate load-carrying capacity of the specimen strengthened by FHB-FRP technique is able to increase by a factor of 2.13 times compared with the beam strengthened with ordinary bond technique (U-jacketing technique). In addition, the cracking and yielding loads are improved more significantly by FHB-FRP technique than U-jacketing technique. Specimens strengthened with FHB-FRP technique have cracks with a more limited distribution and width. Finally, the finite element method (FEM) is conducted to simulate the behavior of the test specimens. The results obtained from the finite element method are compared with experiment. Excellent agreements have been achieved in the comparison of results

  7. Finite Element Modeling and Free Vibration Analysis of Functionally Graded Nanocomposite Beams Reinforced by Randomly Oriented Carbon Nanotubes

    Directory of Open Access Journals (Sweden)

    Benedict Thomas

    2013-12-01

    Full Text Available This article deals with the finite element modeling and free vibration analysis of functionally graded nanocomposite beams reinforced by randomly oriented straight single-walled carbon nanotubes (SWCNTs. Nanostructural materials can be used to alter mechanical, thermal and electrical properties of polymer-based composite materials, because of their superior properties and perfect atom arrangement. Timoshenko beam theory is used to evaluate dynamic characteristics of the beam. The Eshelby–Mori–Tanaka approach based on an equivalent fiber is used to investigate the material properties of the beam. The equations of motion are derived by using Hamilton’s principle. The finite element method is employed to discretize the model and obtain a numerical approximation of the motion equation. Different SWCNTs distributions in the thickness direction are introduced to improve fundamental natural frequency and dynamic behavior of uniform functionally graded nanocomposite beam. Results are presented in tabular and graphical forms to show the effects of various material distributions, carbon nanotube orientations, shear deformation, slenderness ratios and boundary conditions on the dynamic behavior of the beam. The first five normalized mode shapes for functionally graded carbon nanotube reinforced composite (FG-CNTRC beams with different boundary conditions and different carbon nanotubes (CNTs orientation are presented. The results show that the above mentioned effects play very important role on the dynamic behavior of the beam.

  8. The Preparation of an Electron Beam Machine 500 keV/10 mA Instrumentation

    International Nuclear Information System (INIS)

    The preparation of an Electron Beam Machine 500 keV/10 mA instrumentation by using a Distributed Instrumentation System have been done. The system consisting of industrial interfaces PCL-718 ADC 12 bit, PCLD-889 Mux/Prog Gain Amp PCLD-786 Driver Relay with solid state relays, PCL 745 serial com, DC motor 12-24 V/8.6 A with reduction gear 10:1 and a pair of PC's connected with twisted cable and an isolated amplifier AD-210 equipped with high voltage divider. The operation can be done using animation Pascal program on the remote mode using twisted cable and a pair of RS-485 interfaces, some operation sequences such as switch on/off blower unit, water pump cooling unit, filament voltage, anode voltage and some timer's have already been adapted on the computer program. Non intercepting beam monitoring technique have been discussed in this paper. (author)

  9. Attenuation of 10 MeV electron beam energy to achieve low doses does not affect Salmonella spp. inactivation kinetics

    International Nuclear Information System (INIS)

    The effect of attenuating the energy of a 10 MeV electron beam on Salmonella inactivation kinetics was investigated. No statistically significant differences were observed between the D10 values of either Salmonella 4,[5],12:i:- or a Salmonella cocktail (S. 4,[5],12:i:-, Salmonella Heidelberg, Salmonella Newport, Salmonella Typhimurium, Salmonella) when irradiated with either a non-attenuated 10 MeV eBeam or an attenuated 10 MeV eBeam (~2.9±0.22 MeV). The results show that attenuating the energy of a 10 MeV eBeam to achieve low doses does not affect the inactivation kinetics of Salmonella spp. when compared to direct 10 MeV eBeam irradiation. - Highlights: • 10 MeV eBeam energy was attenuated to 2.9±0.22 MeV using HDPE sheets. • Attenuation of eBeam energy does not affect the inactivation kinetics of Salmonella. • Microbial inactivation is independent of eBeam energy in the range of 3–10 MeV

  10. Localized surface grafting reactions on carbon nanofibers induced by gamma and e-beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Evora, M.C., E-mail: cecilia@ieav.cta.br [Institute for Advanced Studies-IEAV/DCTA, Av. Cel Jose Alberto Albano do Amarante, 1-Putim, 12228-001 São Jose dos Campos, SP (Brazil); Araujo, J.R., E-mail: jraraujo@inmetro.gov.br [Instituto Nacional de Metrologia, Qualidade e Tecnologia, Av. Nossa Sra. das Graças, 50, 25250-020 Duque de Caxias, RJ (Brazil); Ferreira, E.H.M. [Instituto Nacional de Metrologia, Qualidade e Tecnologia, Av. Nossa Sra. das Graças, 50, 25250-020 Duque de Caxias, RJ (Brazil); Strohmeier, B.R. [Thermo Fisher Scientific, 5225 Verona Road, Madison, WI 53711 (United States); Silva, L.G.A., E-mail: lgasilva@ipen.br [Institute for Nuclear and Energy Research- IPEN, Av. Prof lineu Prestes, 2242- Cidade Universitaria, 05508-000 SP (Brazil); Achete, C.A. [Instituto Nacional de Metrologia, Qualidade e Tecnologia, Av. Nossa Sra. das Graças, 50, 25250-020 Duque de Caxias, RJ (Brazil)

    2015-04-30

    Graphical abstract: - Highlights: • Methodology for the functionalization of carbon nanofibers was investigated. • Two radiation sources were used to promote grafting reactions: gamma and electron beam. • We report the optimum inhibitor concentration to achieve the functionalization. • Surface of carbon nanofibers showed an increase of oxygen content after irradiation. • The radiation-induced graphitization did not damage the overall sp{sup 2} structure. - Abstract: Electron beam and gamma-ray irradiation have potential application to modify the carbon fiber nanostructures in order to produce useful defects in the graphitic structure and create reactive sites. In this study, the methodology to functionalize carbon nanofiber (CNF), via a radiation process and using acrylic acid as a source of oxygen functional groups, was investigated. The samples were submitted to a direct grafting radiation process with electron beam and gamma-ray source. Several parameters were changed such as: acrylic acid concentration, radiation dose and percentage of inhibitor necessary to achieve functionalization, with higher percentage of oxygen functional groups on CNF surface, and better dispersion. The better results achieved were when mixing CNF in a solution of acrylic acid with 6% of inhibitor (FeSO{sub 4}·7H{sub 2}O) and irradiated at 100 kGy. The samples were characterized by X-ray photoelectron spectroscopy and the surface composition (atomic%) showed a significant increase of oxygen content for the samples after irradiation. Also, the dispersion of the functionalized CNF in water was stable during months which may be a good indication that the functionalization process of CNF via ionizing radiation was successful.

  11. Neutral beam heating for jet, construction and test of a quasi-stationary plasma heating system at the 10 MW level

    International Nuclear Information System (INIS)

    Neutral beam injection is one of the two heating methods for JET. During the first stage of operation hydrogen beams will be injected at 80 keV with a beam pulse length of 10 s. The total beam power into the Torus is 18 MW with 10 MW in the full energy beam component. The power will be provided from 16 beam sources with an extracted ion beam current of 60 A each, arranged in two systems of 8 sources. For the second stage of operation the system will be modified to 160 keV deuterium beams, with 30 A extracted beam current per source. (orig.)

  12. Charged particle's flux measurement from PMMA irradiated by 80 MeV/u carbon ion beam

    CERN Document Server

    Agodi, C; Bellini, F; Cirrone, G A P; Collamati, F; Cuttone, G; De Lucia, E; De Napoli, M; Di Domenico, A; Faccini, R; Ferroni, F; Fiore, S; Gauzzi, P; Iarocci, E; Marafini, M; Mattei, I; Muraro, S; Paoloni, A; Patera, V; Piersanti, L; Romano, F; Sarti, A; Sciubba, A; Vitale, E; Voena, C

    2012-01-01

    Hadrontherapy is an emerging technique in cancer therapy that uses beams of charged particles. To meet the improved capability of hadrontherapy in matching the dose release with the cancer position, new dose monitoring techniques need to be developed and introduced into clinical use. The measurement of the fluxes of the secondary particles produced by the hadron beam is of fundamental importance in the design of any dose monitoring device and is eagerly needed to tune Monte Carlo simulations. We report the measurements done with charged secondary particles produced from the interaction of a 80 MeV/u fully stripped carbon ion beam at the INFN Laboratori Nazionali del Sud, Catania, with a Poly-methyl methacrylate target. Charged secondary particles, produced at 90$\\degree$ with respect to the beam axis, have been tracked with a drift chamber, while their energy and time of flight has been measured by means of a LYSO scintillator. Secondary protons have been identified exploiting the energy and time of flight in...

  13. Evaluation of plastic materials for range shifting, range compensation, and solid-phantom dosimetry for carbon-ion beams

    CERN Document Server

    Kanematsu, Nobuyuki; Ogata, Risa

    2012-01-01

    Purpose: Beam range control is the essence of radiotherapy with heavy charged particles. In conventional broad-beam delivery, fine range adjustment is achieved by insertion of range shifting and compensating materials. Ideally, such material should be water equivalent as well as that for dosimetry. In this study, we evaluated dosimetric water equivalency of four common plastics, HDPE, PMMA, PET, and POM, by uniformity of effective densities for carbon-ion-beam interactions. Methods: Using the Bethe formula for stopping, the Gottschalk formula for multiple scattering, and the Sihver formula for nuclear interactions, we calculated the effective densities of the plastics for these interactions. We tested HDPE, PMMA, and POM in carbon-ion-beam experiment and measured attenuations of carbon ions, which were compared with empirical linear-attenuation-model calculations. Results: The theoretical calculations resulted in reduced multiple scattering and increased nuclear interactions for HDPE compared to water, which ...

  14. Laser transformation hardening on rod-shaped carbon steel byGaussian beam

    Institute of Scientific and Technical Information of China (English)

    Jong-Do KIM; Myeong-Hoon LEE; Su-Jin LEE; Woon-Ju KANG

    2009-01-01

    Laser transformation hardening(LTH) is one of the laser surface modification processes. The surface hardening of rod-shaped carbon steel (SM45C) was performed by lathe-based laser composite processor with Gaussian-beam optical head. The LTH characteristics by dominant processes, longitudinal and depth directional hardness distributions and behaviors of phase transformation in hardened zones were examined. Especially, two concepts of circumferential speed and theoretical overlap rate were applied. When laser power increased or circumferential speed decreased, the surface hardening depth gradually increases due to the increased heat input. Moreover, the longitudinal hardness distribution particularly shows periodicity of repetitive increase and decrease, which results from tempering effect by overlap. Finally, the feasibility of laser transformation hardening is verified by using the beam with Gaussian intensity distribution.

  15. Carbon doping of GaN with CBr4 in radio-frequency plasma-assisted molecular beam epitaxy

    OpenAIRE

    Green, D S; Mishra, U. K.; Speck, J.S.

    2004-01-01

    Carbon tetrabromide (CBr4) was studied as an intentional dopant during rf plasma molecular beam epitaxy of GaN. Secondary ion mass spectroscopy was used to quantify incorporation behavior. Carbon was found to readily incorporate under Ga-rich and N-rich growth conditions with no detectable bromine incorporation. The carbon incorporation [C] was found to be linearly related to the incident CBr4 flux. Reflection high-energy electron diffraction, atomic force microscopy and x-ray diffraction wer...

  16. Relative biological effects of carbon ion beams on mouse intestinal crypts

    Energy Technology Data Exchange (ETDEWEB)

    Basaki, Kiyoshi; Abe, Yoshinao [Hirosaki Univ., Aomori (Japan). School of Medicine; Tatsuzaki, Hideo; Akaizawa, Takashi; Ando, Soichiro; Ando, Koichi

    1998-03-01

    The relative biological effect (RBE) of carbon ion beams on mouse intestinal crypt cells were studied. Survival fractions of apoptotic sensitive cells, mitotic delay and colony assay were used for endpoints. Female C3H mice were total body irradiated using a carbon ion beam (290 MeV/u, 6 cm SOBP) at the National Institute of Radiological Science. For counting apoptosis and mitosis, the animals were irradiated either at LET of 70 keV/mm or 40 keV/mm. Fifteen minutes after irradiation, the mice received vincristine sulfate (0.8 mg/kg) and were sacrificed 2 hours and 45 minutes later. For colony assay, the animals were irradiated at an LET of 70 keV/mm and were sacrificed 3.5 days later. Jejunum were excised, fixed and cut into slices. The slides were stained with Hematoxylin and Eosin. Apoptosis-pyknotic cell- and mitosis were counted and survival fractions of apoptotic sensitive cells and mitotic delay time were obtained. The number of colonies were counted and survival fractions per circumference were obtained. Using these endpoints, RBEs were obtained. For survival fractions of apoptotic sensitive cells, no LET difference was observed and RBE was 1.7. For mitotic delay time, RBE was 2.3 and 1.7 at an LET of 70 keV/mm and 40 keV/mm, respectively. For colony assay, the RBE was 2.0-2.1. The different RBEs from three endpoints of the jejunal crypt may reflect each nature of the radiosensitivity to the carbon ion beam. In summary that mitotic delay time exhibited the same RBE as colony assay and RBE regarding apoptosis was less than those RBEs. (author)

  17. Microbial decontaminations of species by 10 MeV E- Beam

    International Nuclear Information System (INIS)

    Spices are used significantly in food industries. These substances contain high microbial contamination that causes the spoilage of the products and it is also hazardous for the health of consumers. Irradiation is one of the most effective methods to decontaminate spices. In this research , the optimum dose of e-beams to reduce microbial contamination of spices is determined. Samples of spices such as: turmeric, black pepper, garlic powder, onion powder, oregano and spice, were packaged in 10 grams, and they were irradiated at the dose of 0-10 kGy by 10 MeV e-beams. After irradiation, the total microbial counts were determined by the pour plating method. The bacterial contamination of different spices was between 105 to 4.7 x 107 cfu/gr and the molds count was between 1.8x102 to 7.2 x 103 cfu/gr. The survival curve of the bacteria was drawn in terms of bio burden versus the radiation dose rates. By determining the D10 value, the minimum dose for reducing the spices microbial contamination up to the optimum limit, were identified

  18. Using of beam spoilers in linear accelerators with photons of 10 MV

    International Nuclear Information System (INIS)

    This work come along of the necessity to utilize an unique High-Energy Electron Linear Accelerator (10 MV) for radiant treatments which require higher doses in the surface levels of tissue. It is analyzed the interposition of acrylic degraders (spoilers) in the beam, especially for opposed and parallel fields in the cases of head and neck. It was analyzed the possible combinations of the following parameters: 1) Field sizes defined at isocenter (100 cm) 6 x 6 cm2, 8 x 8 cm2 and 10 x 10 cm2 ; 2) Surface-spoiler distance (DSS) of 4, 7 and 10 cm; 3) Spoilers with different thickness 1.1 and 1.5 cm. It was observed a displacement of the maximum dose toward the surface, and an increase in the percentile doses in the build-up zone when the spoiler is nearing and/or increasing its thickness. It is verified that the use of spoilers, support the symmetry and plane of the beam inside of the clinically acceptable margins. When the results obtained are analyzed then it is proposed as a calculation method to incorporate an attenuation factor. (Author)

  19. Fractional frequency instability in the 10{sup -14} range with a thermal beam optical frequency reference

    Energy Technology Data Exchange (ETDEWEB)

    McFerran, John J.; Luiten, Andre N. [School of Physics, University of Western Australia, 35 Stirling Highway, Crawley 6009, W.A. (Australia)

    2010-02-15

    We demonstrate a means of increasing the signal-to-noise ratio in a Ramsey-Borde interferometer with spatially separated oscillatory fields on a thermal atomic beam. The {sup 1}S{sub 0}{r_reversible}{sup 3}P{sub 1} intercombination line in neutral {sup 40}Ca is used as a frequency discriminator, with an extended cavity diode laser at 423 nm probing the ground state population after a Ramsey-Borde sequence of 657 nm light-field interactions with the atoms. Evaluation of the instability of the Ca frequency reference is carried out by comparison with (i) a hydrogen-maser and (ii) a cryogenic sapphire oscillator. In the latter case the Ca reference exhibits a square-root {Lambda} variance of 9.2x10{sup -14} at 1 s and 2.0x10{sup -14} at 64 s. This is an order-of-magnitude improvement for optical beam frequency references, to our knowledge. The shot noise of the readout fluorescence produces a limiting square-root {Lambda} variance of 7x10{sup -14}/{radical}({tau}), highlighting the potential for improvement. This work demonstrates the feasibility of a portable frequency reference in the optical domain with 10{sup -14} range frequency instability.

  20. Experimental study on fire protection methods of reinforced concrete beams strengthened with carbon fiber reinforced polymer

    Institute of Scientific and Technical Information of China (English)

    HU Kexu; HE Guisheng; LU Fan

    2007-01-01

    In this paper,two reinforced concrete (RC) beams strengthened with carbon fiber reinforced polymer (CFRP)and attached with thick-painted fire resistant coating were tested for fire resistance following the standard fire testing procedures.The experimental results show that the specimen pasted with the insulated layer of 50 mm in thickness could resist fire for 2.5 h.It is also demonstrated that the steel wire mesh embedded in the insulated layer can effectively prevent it from cracking and eroding under firing.

  1. Mutational effects of γ-rays and carbon ion beams on Arabidopsis seedlings

    OpenAIRE

    Yoshihara, Ryouhei; Nozawa, Shigeki; Hase, Yoshihiro; Narumi, Issay; Hidema, Jun; Sakamoto, Ayako N

    2013-01-01

    To assess the mutational effects of radiation on vigorously proliferating plant tissue, the mutation spectrum was analyzed with Arabidopsis seedlings using the plasmid-rescue method. Transgenic plants containing the Escherichia coli rpsL gene were irradiated with γ-rays and carbon ion beams (320-MeV 12C6+), and mutations in the rpsL gene were analyzed. Mutant frequency increased significantly following irradiation by γ-rays, but not by 320-MeV 12C6+. Mutation spectra showed that both radiatio...

  2. Two Types of Mass Abundance Distributions for Anionic Carbon Clusters Investigated by Laser Vaporization and Pulsed Molecular Beam Techniques

    Institute of Scientific and Technical Information of China (English)

    ZHAI Hua-Jin; LIU Bing-Chen; NI Guo-Quan; XUZhi-Zhan

    2000-01-01

    Two types of mass spectra for anionic carbon clusters Cn- have been revealed using laser vaporization and pulsed molecular beam techniques. The less structured mass spectrum characteristic of the magic-numbers at n = 5, 8,11, 15, and 17 is established at the early stage of the cluster formation process, namely, in the laser vaporization process. The more structured one is featured for a regular odd-even alternation and the magic numbers at n =10, 12, 16, 18, 22, and 28, and has been developed only after extensive clustering and qnenching processes, where low-energy electron attachment plays a vital role. Transition between these two types of mass spectra can be realized by controlling either the strength of the pulsed gas flow or the synchronism between the gas flow and the laser vaporization.

  3. Treatment of industrial effluents using electron beam accelerator and adsorption with activated carbon. A comparative study

    International Nuclear Information System (INIS)

    Several methods are used In the pollutant removal from Industrial and domestic wastewater. However when the degradation of toxic organic pollutants, mainly the recalcitrant is objectified, the conventional treatments usually do not meet the desirable performance in the elimination or decrease the impact when the effluent are released to the environment what takes to the research of alternative methods that seek the improvement of the efficiency of the wastewater treatment systems jointly employees or separately. This work presents a study of degradation/removal of pollutants organic compounds comparing two methods using radiation from industrial electron beam and granular activated carbon (GAC). The removal efficiency of the pollutants was evaluated and it was verified that the efficiency of adsorption with activated carbon is similar to the radiation method. The obtained results allowed to evaluated the relative costs of these methods. (author)

  4. Low carbon content NiTi shape memory alloy produced by electron beam melting

    Directory of Open Access Journals (Sweden)

    Otubo Jorge

    2004-01-01

    Full Text Available Earlier works showed that the use of electron beam melting is a viable process to produce NiTi shape memory alloy. In those works a static and a semi-dynamic processes were used producing small shell-shaped and cylindrical ingots respectively. The main characteristics of those samples were low carbon concentration and good composition homogeneity throughout the samples. This paper presents the results of scaling up the ingot size and processing procedure using continuous charge feeding and continuous casting. The composition homogeneity was very good demonstrated by small variation in martensitic transformation temperatures with carbon content around 0.013wt% compared to 0.04 to 0.06wt% of commercial products.

  5. Transplantation of ES cells to Parkinson model rat irradiated with carbon ion beam

    International Nuclear Information System (INIS)

    The present study was designed to make a new Parkinson disease model using carbon ion beam. We irradiated right medial forebrain bundle of adult SD rats with charged carbon particles (290 MeV/nucleon, Mono peak, 150 Gy) and damaged right dopaminergic neurons pathway. To irradiate precisely, rats were set in the stereotactic frame with ear bars. Four weeks after the irradiation, behavioral test and in vitro autoradiography showed hemi-Parkinson model as well as 6-OHDA lesioned rats. Pathological examinations showed cell death, gliosis and inflammations at the irradiated area. However, no obvious alteration was observed at the surrounding normal tissue. These results indicated utility and validity of this method. (author)

  6. 电子束再生粉状活性炭的研究%Study on Regeneration of Powdered Activated Carbon by Electron Beam

    Institute of Scientific and Technical Information of China (English)

    吴明红; 包伯荣; 陈捷; 陆丽蓉

    2000-01-01

    The powdered activated carbon which had adsorbed phenylglycine solution from pharmaceutics factory can be regenerated by mean of irradiation of high-energy electron beams in oxygen, nitrogen and water vapor respectively. The effects of radiation dose and beam current on regeneration of activated carbon in different atmosphere were studied. Differential scanning calorimetry (DSC) and the iodine number of activated carbon were used to monitor the change of carbon adsorption. The results show that the powder activated carbon polluted with phenlglycine could be regenerated effectively by irradiation of high energy electron beams in nitrogen stream. The generation did not need high temperature, and the weight loss of carbon and energy consumption were minimum.

  7. Study on Regeneration of Powdered Activated Carbon by Electron Beam%电子束再生粉状活性炭的研究

    Institute of Scientific and Technical Information of China (English)

    吴明红; 包伯荣; 陈捷; 陆丽蓉

    2001-01-01

    The powdered activated carbon which had adsorbed phenylglycine solution from pharmaceutics factory can be regenerated by mean of irradiation of high-energy electron beams in oxygen, nitrogen and water vapor respectively. The effects of radiation dose and beam current on regeneration of activated carbon in different atmosphere were studied. Differential scanning calorimetry (DSC) and the iodine number of activated carbon were used to monitor the change of carbon adsorption. The results show that the powder activated carbon polluted with phenlglycine could be regenerated effectively by irradiation of high energy electron beams in nitrogen stream. The generation did not need high temperature, and the weight loss of carbon and energy consumption were minimum.

  8. Manufacturing composite beams reinforced with three-dimensionally patterned-oriented carbon nanotubes through microfluidic infiltration

    International Nuclear Information System (INIS)

    Highlights: ► Composite beams reinforced with 3D patterned-oriented nanotubes are manufactured. ► Process-induced orientation of nanotubes in 3D microfluidic networks is studied. ► The stiffness is compared with the values obtained from a micromechanical model. ► The model predictions give a close estimation at different processing conditions. ► The present manufacturing method opens new prospects for the design of composites. -- Abstract: Functionalized single-walled carbon nanotubes (SWCNTs)/epoxy nanocomposite suspensions were prepared and injected into three-dimensional (3D) interconnected microfluidic networks in order to fabricate composite beams reinforced with patterned-oriented nanotubes. The microfluidic networks were fabricated by the robotized direct deposition of fugitive ink filaments in a layer-by-layer sequence onto substrates, followed by their epoxy encapsulation and the ink removal. Then, the nanocomposite suspensions prepared by ultrasonication and three-roll mill mixing methods were injected into the empty networks under two different controlled and constant pressures in order to subject the suspensions to different shear conditions in the microchannels. Morphological studies revealed that the SWCNTs were preferentially aligned in the microchannels along the flow direction at the higher injection pressure. The improvement of Young’s modulus of the manufactured 3D-reinforced rectangular beams prepared at the high injection pressure was almost doubled when compared to that of beams prepared at the low injection pressure. Finally, the stiffness of the 3D-reinforced beams was compared with the theoretically predicted values obtained from a micromechanical model. The analytical predictions give a close estimation of the stiffness at different micro-injection conditions. Based on the experimental and theoretical results, the present manufacturing technique enables the spatial orientation of nanotube in the final product by taking

  9. Neutron contamination of Varian Clinac iX 10 MV photon beam using Monte Carlo simulation

    Science.gov (United States)

    Yani, S.; Tursinah, R.; Rhani, M. F.; Soh, R. C. X.; Haryanto, F.; Arif, I.

    2016-03-01

    High energy medical accelerators are commonly used in radiotherapy to increase the effectiveness of treatments. As we know neutrons can be emitted from a medical accelerator if there is an incident of X-ray that hits any of its materials. This issue becomes a point of view of many researchers. The neutron contamination has caused many problems such as image resolution and radiation protection for patients and radio oncologists. This study concerns the simulation of neutron contamination emitted from Varian Clinac iX 10 MV using Monte Carlo code system. As neutron production process is very complex, Monte Carlo simulation with MCNPX code system was carried out to study this contamination. The design of this medical accelerator was modelled based on the actual materials and geometry. The maximum energy of photons and neutron in the scoring plane was 10.5 and 2.239 MeV, respectively. The number and energy of the particles produced depend on the depth and distance from beam axis. From these results, it is pointed out that the neutron produced by linac 10 MV photon beam in a typical treatment is not negligible.

  10. Study on producing calorimeter for dose measurement of electron beam 10 MeV irradiation

    International Nuclear Information System (INIS)

    Calorimeter, used in measuring dose irradiated from a 10 MeV electron beam, was researched and produced at VINAGAMMA. Cylinder Polystyrene disc with 136 mm wide and 18 mm thick was determined, having the same size as described in ISO/ASTM 51631 - 2003(E). Dose distribution in the polystyrene structure along the radius and the thickness was estimated. Then, correction factor for the calorimeter was estimated as 1.17, which is about 3% less than a transfer calorimeter. The calorimeter has a maximum dose of about 2,000 kGy. (author)

  11. Study of the RP-10 reactor neutron beam applied to the neutron radiography

    International Nuclear Information System (INIS)

    We have studied the RP-10 reactor radial neutron beam No. 3, which is used for neutron radiographies, by comparing radiograph's with and without the inner duct, and neutron flux determination with in flakes along the external duct, being the presence of photons creating signals at comparable levels of neutron effects, which reduce the quality of the analysis, values around 106 and 104 n/cm2s for thermal and epithermal flux were obtained respectively. It is recommended evaluate the design of the internal duct which presents strong photon emission. (authors).

  12. The CBS-The Most Cost Effective and High Performance Carbon Beam Source Dedicated for a New Generation Cancer Therapy

    CERN Document Server

    Kumada, Masayuki; Leivichev, E B; Parkhomchuk, Vasily; Podgorny, Fedor; Rastigeev, Sergey; Reva, Vladimir B; Skrinsky, Aleksander Nikolayevich; Vostrikov, Vladimir

    2005-01-01

    A Carbon ion beam is a superior tool to x-rays or a proton beam in both physical and biological doses in treating a cancer. A Carbon beam has an advantage in treating radiation resistant and deep-seated tumors. Its radiological effect is of a mitotic independent nature. These features improve hypofractionation, typically reducing the number of irradiations per patient from 35 to a few. It has been shown that a superior QOL(Quality Of Life) therapy is possible by a carbon beam.The only drawback is its high cost. Nevertheless, tens of Prefectures and organizations are eagerly considering the possibility of having a carbon ion therapy facility in Japan. Germany, Austria, Italy, China, Taiwan and Korea also desire to have one.A carbon beam accelerator of moderate cost is about 100 Million USD. With the "CBS" design philosophy, which will be described in this paper, the cost could be factor of 2 or 3 less, while improving its performance more than standard designs. Novel extraction techniques, a new approach to a ...

  13. Dual-ion-beam deposition of carbon films with diamond-like properties

    Science.gov (United States)

    Mirtich, M. J.; Swec, D. M.; Angus, J. C.

    1985-01-01

    A single and dual ion beam system was used to generate amorphous carbon films with diamond like properties. A methane/argon mixture at a molar ratio of 0.28 was ionized in the low pressure discharge chamber of a 30-cm-diameter ion source. A second ion source, 8 cm in diameter was used to direct a beam of 600 eV Argon ions on the substrates (fused silica or silicon) while the deposition from the 30-cm ion source was taking place. Nuclear reaction and combustion analysis indicate H/C ratios for the films to be 1.00. This high value of H/C, it is felt, allowed the films to have good transmittance. The films were impervious to reagents which dissolve graphitic and polymeric carbon structures. Although the measured density of the films was approximately 1.8 gm/cu cm, a value lower than diamond, the films exhibited other properties that were relatively close to diamond. These films were compared with diamond like films generated by sputtering a graphite target.

  14. Effects of evolving surface morphology on yield during focused ion beam milling of carbon

    International Nuclear Information System (INIS)

    We investigate evolving surface morphology during focused ion beam bombardment of C and determine its effects on sputter yield over a large range of ion dose (1017-1019 ions/cm2) and incidence angles (Θ = 0-80o). Carbon bombarded by 20 keV Ga+ either retains a smooth sputtered surface or develops one of two rough surface morphologies (sinusoidal ripples or steps/terraces) depending on the angle of ion incidence. For conditions that lead to smooth sputter-eroded surfaces there is no change in yield with ion dose after erosion of the solid commences. However, for all conditions that lead to surface roughening we observe coarsening of morphology with increased ion dose and a concomitant decrease in yield. A decrease in yield occurs as surface ripples increase wavelength and, for large Θ, as step/terrace morphologies evolve. The yield also decreases with dose as rippled surfaces transition to have steps and terraces at Θ = 75o. Similar trends of decreasing yield are found for H2O-assisted focused ion beam milling. The effects of changing surface morphology on yield are explained by the varying incidence angles exposed to the high-energy beam.

  15. Effects of carbon ion beam irradiation on the shoot regeneration from in vitro axillary bud explants of the Impatiens hawkeri

    Science.gov (United States)

    Zhou, Libin; Zhou, Libin; Li, Wenjian; Li, Ping; Dong, Xicun; Qu, Ying; Ma, Shuang; Li, Qiang

    Accelerated ion beams is an excellent mutagen in plant breeding which can induce higher mutation frequencies and wider mutation spectrum than those of low linear energy transfer (LET) irradiations, such as X-rays (Okamura et al. 2003, Yamaguchi et al. 2003). Mutation breeding operation of two Saintpaulia ionahta cultivars using the method combining plant tissue culture technique and carbon ion beam irradiations were set out at Institute of Modern Physics from 2005 (Zhou et al. 2006). The effects of 960 MeV carbon ion beam and 8 MeV X-ray irradiations on regenerated shoots of Impatiens hawkeri from another kind of explants named in vitro axillary buds explants were studied recently. The biology endpoints in this study included relative number of roots (RNR), relative length of roots (RLR), relative height of shoots (RHS), relative number of nodes (RNN), survival fraction (SF) and morphology changes in the regenerated shoots. The experimental results showed that carbon ion beams inhibited the root and stem developments of axillary bud explants more severely than X-rays did. And the 50% lethal dose (LD50 ) is about 23.3 Gy for the carbon ion beam and 49.1 Gy for the X-rays, respectively. Relative biological effectiveness (RBE) of Impatiens hawkeri with respect to X-rays according to 50% SF was about two. Secondly, the percentage of shoots regenerated with malformed shoots including curliness, carnification, nicks in all Impatiens hawkeri axillary bud explants irradiated with carbon ion beam at 20 Gy accounted for 55.6%, while the highest number for the 40 Gy X-ray irradiation was 40%. Last, many regenerated shoots whose vascular bundle fused together were obtained only from explants irradiated with carbon ion beams. Based on the results above, it can be concluded that the effect of mutation induction by carbon ion beam irradiation on the axillary explants of Impatiens hawkeri is better than that by X-ray irradiation; and the optimal mutagenic dose varies from 20 Gy

  16. Flexural rigidity evolvement laws of reinforced concrete beams strengthened with carbon fiber laminates

    Institute of Scientific and Technical Information of China (English)

    NIU Peng-zhi; HUANG Pei-yan; DENG Jun; HAN Qiang

    2007-01-01

    Extensive research has shown that externally bonded carbon fiber reinforced polymer (CFRP) laminates are particularly suitable for improving the fatigue behavior of reinforced concrete (RC) beams. This paper presents the research on flexural rigidity evolvement laws by testing 14 simple-supported RC beams strengthened with carbon fiber laminates (CFL) under cyclic load, and 2 under monotone load as a reference. The cyclic load tests revealed the peak load applied onto the surface of a supported RC beam strengthened with CFL is linear to the logarithm of its fatigue life, and the flexural rigidity evolvement undergoes three distinct phases: a rapid decrease from the start to about 5% of the fatigue life; an even development from 5% to about 99% of the fatigue life; and a succedent rapid decrease to failure. When the ratio of fatigue cycles to the fatigue life is within 0.05 to 0.99, the flexural rigidity varies linearly with the ratio. The peak load does not affect the flexural rigidity evolvement if it is not high enough to make the main reinforcements yield. The dependences of the flexural rigidity of specimens formed in the same group upon their fatigue cycles normalized by fatigue life are almost coincident. This implies the flexural rigidity may be a material parameter independent of the stress level. These relationships of flexural rigidity to fatigue cycles, and fatigue life may be able to provide some hints for fatigue design and fatigue life evaluation of RC member strengthened with CFL; nevertheless the findings still need verifying by more experiments.

  17. Analytic expressions for the inelastic scattering and energy loss of electron and proton beams in carbon nanotubes

    International Nuclear Information System (INIS)

    We have determined ''effective'' Bethe coefficients and the mean excitation energy of stopping theory (I-value) for multiwalled carbon nanotubes (MWCNTs) and single-walled carbon nanotube (SWCNT) bundles based on a sum-rule constrained optical-data model energy loss function with improved asymptotic properties. Noticeable differences between MWCNTs, SWCNT bundles, and the three allotropes of carbon (diamond, graphite, glassy carbon) are found. By means of Bethe's asymptotic approximation, the inelastic scattering cross section, the electronic stopping power, and the average energy transfer to target electrons in a single inelastic collision, are calculated analytically for a broad range of electron and proton beam energies using realistic excitation parameters.

  18. Analytic expressions for the inelastic scattering and energy loss of electron and proton beams in carbon nanotubes

    Science.gov (United States)

    Emfietzoglou, D.; Kyriakou, I.; Garcia-Molina, R.; Abril, I.; Kostarelos, K.

    2010-09-01

    We have determined "effective" Bethe coefficients and the mean excitation energy of stopping theory (I-value) for multiwalled carbon nanotubes (MWCNTs) and single-walled carbon nanotube (SWCNT) bundles based on a sum-rule constrained optical-data model energy loss function with improved asymptotic properties. Noticeable differences between MWCNTs, SWCNT bundles, and the three allotropes of carbon (diamond, graphite, glassy carbon) are found. By means of Bethe's asymptotic approximation, the inelastic scattering cross section, the electronic stopping power, and the average energy transfer to target electrons in a single inelastic collision, are calculated analytically for a broad range of electron and proton beam energies using realistic excitation parameters.

  19. Charge exchange recombination spectroscopy measurements in the extreme ultraviolet region of central carbon concentrations during high power neutral beam heating in TFTR [Tokamak Fusion Test Reactor

    International Nuclear Information System (INIS)

    The carbon concentration in the central region of TFTR discharges with high power neutral beam heating has been measured by charge-extracted recombination spectroscopy (CXRS) of the C+5 n = 3--4 transition in the extreme ultraviolet region. The carbon concentrations were deduced from absolute measurements of the line brightness using a calculation of the beam attenuation and the appropriate cascade-corrected line excitation rates. As a result of the high ion temperatures in most of the discharges, the contribution of beam halo neutrals to the line brightness was significant and therefore had to be included in the modeling of the data. Carbon concentrations have been measured in discharges with Ip = 1.0-1.6 MA and beam power in the range of 2.6-30 MW, including a number of supershots. The results are in good agreement with carbon concentrations deduced from the visible bremsstrahlung Zeff and metallic impurity concentrations measured by x-ray pulse-height analysis, demonstrating the reliability of the atomic rates used in the beam attenuation and line excitation calculations. Carbon is the dominant impurity species in these discharges; the oxygen concentration measured via CXRS in a high beam power case was 0.0006 of ne, compard to 0.04 for carbon. Trends with Ip and beam power in the carbon concentration and the inferred deuteron concentration are presented. The carbon concentration is independent of Ip and decreases from 0.13 at 2.6 MW beam power to 0.04 at 30 MW, while the deuteron concentration increases from 0.25 to 0.75 over the same range of beam power. These changes are primarily the result of beam particle fueling, as the carbon density did not vary significantly with beam power. The time evolutions of the carbon and deuteron concentrations during two high power beam pulses, one which exhibited a carbon bloom and one which did not, are compared. 30 refs., 12 figs., 2 tabs

  20. Measurement of analyzing power for proton-carbon elastic scattering in the coulomb-nuclear interference region with a 22-GeV/c polarized proton beam.

    Science.gov (United States)

    Tojo, J; Alekseev, I; Bai, M; Bassalleck, B; Bunce, G; Deshpande, A; Doskow, J; Eilerts, S; Fields, D E; Goto, Y; Huang, H; Hughes, V; Imai, K; Ishihara, M; Kanavets, V; Kurita, K; Kwiatkowski, K; Lewis, B; Lozowski, W; Makdisi, Y; Meyer, H-O; Morozov, B V; Nakamura, M; Przewoski, B; Rinckel, T; Roser, T; Rusek, A; Saito, N; Smith, B; Svirida, D; Syphers, M; Taketani, A; Thomas, T L; Underwood, D; Wolfe, D; Yamamoto, K; Zhu, L

    2002-07-29

    The analyzing power for proton-carbon elastic scattering in the Coulomb-nuclear interference region of momentum transfer, 9.0x10(-3)<-t<4.1x10(-2) (GeV/c)(2), was measured with a 21.7 GeV/c polarized proton beam at the Alternating Gradient Synchrotron of Brookhaven National Laboratory. The ratio of hadronic spin-flip to nonflip amplitude, r(5), was obtained from the analyzing power to be Rer(5)=0.088+/-0.058 and Imr(5)=-0.161+/-0.226. PMID:12144435

  1. Ion-beam and microwave-stimulated functionalization and derivatization of carbon nanotubes

    Science.gov (United States)

    Makala, Raghuveer S.

    Derivatizing carbon nanotubes (CNTs) with other low-dimensional nanostructures is of widespread interest for creating CNT-based nanocomposites and devices. Conventional routes based on wet-chemical oxidation or hydrophobic adsorption do not allow premeditated control over the location or spatial extent of functionalization. Moreover, aggressive oxidative treatments and agitation in corrosive environments lead to CNT shortening, damage, and incorporation of excess impurity concentrations. Thus, it is imperative to explore and develop alternative functionalization methods to overcome these shortcomings. The work presented in this thesis outlines two such methodologies: one based on focused ion irradiation for siteselective functionalization and the other that employs microwave-stimulation for mild, yet rapid and homogenous CNT functionalization. The utility of 10 and 30 kcV Ga+ focused ion beams (FIB) to thin, slice, weld, and alter the structure and composition at precise locations along the CNT axis is presented. This strategy of harnessing ion-beam-induced defect generation and doping is attractive for modulating chemical and electrical properties along the CNT length, and fabricate CNT-based heterostructures and networks. A novel approach that utilizes focused ion irradiation to site-selectively derivatize preselected segments of CNTs with controlled micro-/nano-scale lateral spatial resolution is demonstrated. Irradiation followed by air-exposure results in functionalized CNT segments ranging from the nanoscopic to the macroscopic scale. The functional moieties are utilized to site-selectively anchor Au nanoparticles, fluorescent nanospheres, an amino acid---lysine, a charge-transfer metalloprotein---azurin, and a photoactive protein---bacteriorhodopsin by means of electrostatic or covalent interactions. This approach is versatile and can be extended to obtaining other molecular moieties and derivatives opening up possibilities for building new types of nano

  2. Assessment of adhesive setting time in reinforced concrete beams strengthened with carbon fibre reinforced polymer laminates

    International Nuclear Information System (INIS)

    Highlights: ► This study investigated the effect of adhesive setting time on the modal parameters. ► Modal parameters recommend the 18th day as the maturity age of the adhesive. ► Static data recommend 7th day as the maturity age of the adhesive. ► Setting time affects the modal parameters as tool for assessment repaired structures. ► Carrying the modal parameters after 1st day results in 55% loss of the actual improvement. -- Abstract: The strengthened effectiveness and the performance capacity of repaired Reinforced Concrete (RC) structures with Carbon Fibre Reinforced Polymer (CFRP) sheets is dependent on the properties of the adhesive interface layer. Adhesive material requires a specific setting time to achieve the maximum design capacity. Adhesive producer provides technical data which demonstrates the increase with time of the capacity, up to the maximum. The aim of this study is to investigate the effect of the adhesive setting time on the modal parameters as an indication of the effectiveness of CFRP on repaired RC beams. Firstly, datum modal parameters were determined on the undamaged beam and subsequently the parameters were obtained when damaged was induced on the RC beam by application of load until the appearance of the first crack. Finally, the RC beam is repaired with externally bonded CFRP sheets, and modal parameters are once again applied after 0.5, 1, 2, 3, 5, 8, 11, 15 and 18 days. The comparison is made with the data based on half day results in order to monitor the change in the modal parameters corresponding to the adhesive setting time. The modal parameters where used as indicators for the effectiveness of CFRP are affected by the adhesive time as shown in this study. Results are compared with the adhesive technical data provided by the adhesive producer.

  3. Time course of reoxygenation in experimental murine tumors after carbon-beam and X-ray irradiation

    International Nuclear Information System (INIS)

    We compared the tumor reoxygenation patterns in three different murine tumor cell lines after X-irradiation with those after carbon-beam irradiation using a heavy-ion medical accelerator (HIMAC) system. The tumors of the cell lines SCCVII, SCCVII-variant-1 and EMT6 on the hind legs of mice received local priming irradiation with a carbon-beam (8 Gy, 73 keV/μm in LET, 290 MeV/u, 6 cm SOBP) or X-rays (13 Gy, 250 kVp). After various intervals, the mice were given whole-body test irradiation (16 Gy, 250 kVp X-ray) either in air or after they were killed. The hypoxic fractions were estimated as the proportions of the surviving fractions of the tumors in killed mice to those in air-breathing mice. In the SCCVII tumors, the hypoxic fractions at 0.5 h were 50% and 21% (p<0.05) after the priming x-irradiation and carbon-beam irradiation, respectively. In the SCCVII-variant-1 tumors, the hypoxic fractions were 85% and 82% at 0.5 h, 84% and 20% at 12 h (p<0.01), and 21% and 31% at 24 h after X-ray and after carbon-beam irradiation, respectively. In the EMT6 tumors, the reoxygenation patterns after X-irradiation and carbon-beam irradiation were quite similar. We concluded that the reoxygenation pattern differed among the three tumor cell lines, and that reoxygenation tended to occur more rapidly after carbon-beam irradiation than after X-irradiation for SCCVII and SCCVII-variant-1 tumors. (author)

  4. Characterization of carbon-doped InSb diode grown by molecular beam epitaxy

    International Nuclear Information System (INIS)

    Carbon-doped p-type InSb layers grown by solid source molecular beam epitaxy are characterized using a p+-n diode structure. Based on the combination of current-voltage, secondary ion mass spectroscopy and x-ray diffraction measurements, carbon is proven to be an effective p-type dopant for InSb with hole concentration reaching the range of 1019 cm-3. It is also proven that the use of the Hall effect to determine the hole concentration in the p-type InSb layer may be unreliable in cases where the leakage current in the p+-n junction is high. A thermal trap-assisted tunnelling model with two trap levels successfully explains the origin of leakage current mechanisms in the carbon-doped InSb samples. Good agreement between measured and calculated dc characteristics of the diodes at reverse bias up to -3 V from 30 to 120 K supports the validity of the current transport model

  5. Emulsion Cloud Chamber technique to measure the fragmentation of a high-energy carbon beam

    CERN Document Server

    De Lellis, G; Buontempo, S; Capua, F D; Furusawa, Y; Lavina, L S; Marotta, A; Migliozzi, P; Naganawa, N; Petukhov, Yu P; Pistillo, C; Russo, A; Strolin, P; Tioukov, V; Toshito, T; Yasuda, N

    2007-01-01

    Beams of Carbon nuclei are now in use or planned to be used in various centers for cancer treatment around the world. The knowledge of the fragmentation of Carbon nuclei when they interact with the human body is important for evaluating of the spatial profile of their energy deposition in the tissues, hence the damage to tissues neighbouring the tumor. To this purpose, the identification of the fragmentation products is a key element. We present in this paper the charge measurement of about 3000 fragments produced by the interaction of $^{12}$C nuclei with an energy of 400 MeV/nucleon in a detector simulating the density of the human body. The nuclear emulsion technique is used, by means of the so-called Emulsion Cloud Chamber. The nuclear emulsions are inspected using fast automated microscopes recently developed. A charge assignment efficiency of more than 99% is achieved. The separation of Hydrogen, Helium, Lithium, Berillium, Boron and Carbon can be achieved at two standard deviations or considerably more...

  6. Ion beam analysis of tungsten layers in EUROFER model systems and carbon plasma facing components

    Science.gov (United States)

    Ström, Petter; Petersson, Per; Rubel, Marek; Primetzhofer, Daniel; Brezinsek, Sebastijan; Kreter, Arkadi; Unterberg, Bernhard; Sergienko, Gennady; Sugiyama, Kazuyoshi

    2016-03-01

    The tungsten enriched surface layers in two fusion-relevant EUROFER steel model samples, consisting of an iron-tungsten mixture exposed to sputtering by deuterium ions, were studied by Rutherford backscattering spectrometry and medium energy ion scattering. Exposure conditions were the same for the two samples and the total amount of tungsten atoms per unit area in the enriched layers were similar (2 · 1015 and 2.4 · 1015 atoms/cm2 respectively), despite slightly different initial atomic compositions. A depth profile featuring exponential decrease in tungsten content towards higher depths with 10-20 at.% of tungsten at the surface and a decay constant between 0.05 and 0.08 Å-1 was indicated in one sample, whereas only the total areal density of tungsten atoms was measured in the other. In addition, two different beams, iodine and chlorine, were employed for elastic recoil detection analysis of the deposited layer on a polished graphite plate from a test limiter in the TEXTOR tokamak following experiments with tungsten hexafluoride injection. The chlorine beam was preferred for tungsten analysis, mainly because it (as opposed to the iodine beam) does not give rise to problems with overlap of forward scattered beam particles and recoiled tungsten in the spectrum.

  7. Extraction of 10 sec/75 keV/70 A ion beams at prototype neutral beam injector unit for JT-60

    International Nuclear Information System (INIS)

    A prototype neutral beam injector for JT-60 was constructed to test and demonstrate a single beam line performance before fabrication of fourteen injector units for JT-60. The system has been operated over 4 months without serious troubles. Ion beams of 10 sec/75 keV/70 A were extracted repeatedly and most of design values were achieved. Accelerator grids were stable during 10 sec pulse, and other components of the system were confirmed to be sufficiently reliable. The system was also operated with a magnetic field which simulated a stray field from JT-60 tokamak. With the stray field applied, no choking effect in a drift tube like PLT or Culham effects were observed at all. (author)

  8. Deflection analysis of reinforced concrete beams strengthened with carbon fibre reinforced polymer under long-term load action

    Institute of Scientific and Technical Information of China (English)

    Mykolas DAUGEVI(C)IUS; Juozas VALIVONIS; Gediminas MAR(C)IUKAITIS

    2012-01-01

    This paper presents the results of an experimental research on reinforced concrete beams strengthened with an external carbon fibre reinforced polymer (CFRP) layer under long-term load action that lasted for 330 d.We describe the characteristics of deflection development of the beams strengthened with different additional anchorages of the external carbon fibre composite layer during the period of interest.The conducted experiments showed that the additional anchorage influences the slip of the extemal layer with respect to the strengthened element.Thus,concrete and carbon fibre composite interface stiffness decreases with a long-term load action.Therefore,the proposed method of analysis based on the built-up-bars theory can be used to estimate concrete and carbon fibre composite interface stiffness in the case of long-term load.

  9. An Intense $\\gamma$-ray Beam Line of 10 MeV Order Based on Compton Backscattering

    CERN Document Server

    Guo, W; Chen, J G; Lu, G C; Ma, Y G; Shen, W Q; Wang, C B; Wang, H W; Wei, Z Y; Xu, J Q; Xu, W; Xu, Y; Yan, Z; Yuan, R Y

    2006-01-01

    Shanghai Laser Electron Gamma Source, a $\\gamma$-ray beam line of 10MeV order was proposed recently. The beam line is expected to generate $\\gamma$-ray with maximum energy of 22MeV by backward Compton scattering between CO$_2$ laser and electron in the 3.5GeV storage ring of future Shanghai Synchrotron Radiation Facility. The flux of non-collimated $\\gamma$-ray can be 10$^9$ $\\sim$ 10$^{10}$s$^{-1}$ if a commercial CO$_2$ laser of 100W order output power is employed and injected with optimized settings.

  10. Electron-beam assisted selective growth of graphenic carbon thin films on SiO2/Si and quartz substrates

    OpenAIRE

    Knyazev, Maxim; Sedlovets, Daria; Trofimov, Oleg; Redkin, Arkady

    2015-01-01

    The first selective growth of graphenic carbon thin films on silicon dioxide is reported. A preliminary e-beam exposure of the substrate is found to strongly affect the process of such films growth. The emphasis is placed on the influence of substrate exposure on the rate of carbon deposition. The explanation of this effect is proposed. The data of electrical and optical measurements and the results of atomic force and scanning electron microscopy and Raman spectroscopy studies are reported. ...

  11. Integration and evaluation of automated Monte Carlo simulations in the clinical practice of scanned proton and carbon ion beam therapy

    International Nuclear Information System (INIS)

    Monte Carlo (MC) simulations of beam interaction and transport in matter are increasingly considered as essential tools to support several aspects of radiation therapy. Despite the vast application of MC to photon therapy and scattered proton therapy, clinical experience in scanned ion beam therapy is still scarce. This is especially the case for ions heavier than protons, which pose additional issues like nuclear fragmentation and varying biological effectiveness. In this work, we present the evaluation of a dedicated framework which has been developed at the Heidelberg Ion Beam Therapy Center to provide automated FLUKA MC simulations of clinical patient treatments with scanned proton and carbon ion beams. Investigations on the number of transported primaries and the dimension of the geometry and scoring grids have been performed for a representative class of patient cases in order to provide recommendations on the simulation settings, showing that recommendations derived from the experience in proton therapy cannot be directly translated to the case of carbon ion beams. The MC results with the optimized settings have been compared to the calculations of the analytical treatment planning system (TPS), showing that regardless of the consistency of the two systems (in terms of beam model in water and range calculation in different materials) relevant differences can be found in dosimetric quantities and range, especially in the case of heterogeneous and deep seated treatment sites depending on the ion beam species and energies, homogeneity of the traversed tissue and size of the treated volume. The analysis of typical TPS speed-up approximations highlighted effects which deserve accurate treatment, in contrast to adequate beam model simplifications for scanned ion beam therapy. In terms of biological dose calculations, the investigation of the mixed field components in realistic anatomical situations confirmed the findings of previous groups so far reported only in

  12. Precise measurement of single carbon nanocoils using focused ion beam technique

    Science.gov (United States)

    Nakamura, Yasushi; Suda, Yoshiyuki; Kunimoto, Ryuji; Iida, Tamio; Takikawa, Hirofumi; Ue, Hitoshi; Shima, Hiroyuki

    2016-04-01

    We have developed a precise resistivity measurement system for quasi-one-dimensional nanomaterials using a focused ion beam. The system enables the resistivity of carbon nanocoils (CNCs) to be measured and its dependence on coil geometry to be elucidated. At room temperature, the resistivity of CNCs tended to increase with coil diameter, while that of artificially graphitized CNCs remained constant. These contrasting behaviors indicate coil-diameter-induced enhancement in structural disorder internal to CNCs. Low-temperature resistivity measurements performed on the CNCs revealed that electron transport through the helical axis is governed by the variable range hopping mechanism. The characteristic temperature in variable range hopping theory was found to systematically increase with coil diameter, which supports our theory that the population of sp2-domains in CNCs decreases considerably with coil diameter.

  13. Radiation grafting of styrene onto polypropylene fibres by a 10 MeV electron beam

    International Nuclear Information System (INIS)

    The radiation-induced graft copolymerization is an effective method for modification of the chemical and physical properties of polypropylene. Graft copolymerization of styrene onto polypropylene fibers has been studied by simultaneous irradiation method, using a 10 MeV electron beam. Samples were irradiated in an environment of nitrogen gas. The effects of radiation dose and styrene concentration in methanol, on the grafting yield were investigated. The effects of polyfunctional monomer, i.e., trimethylopropane trimethacrylate (TMPTMA) and acid (sulfuric acid) on the grafting yield were also examined. The grafted samples were then sulfonated and allowed to react with solution of a basic dye. The samples were characterized by mechanical properties and thermal stability. The mechanical properties of the radiated samples were reduced and the grafted samples had lower mechanical properties

  14. New onset of myasthenia gravis 10 years after proton beam therapy for thymoma.

    Science.gov (United States)

    Karasaki, Takahiro; Murakawa, Tomohiro; Nagayama, Kazuhiro; Nitadori, Jun-Ichi; Anraku, Masaki; Kikuchi, Yoshinao; Shinozaki-Ushiku, Aya; Igaki, Hiroshi; Nakajima, Jun

    2016-05-01

    A 36-year-old woman underwent proton beam therapy for encapsulated type B1 thymoma for curative intent at 66 GyE. Radiographically partial response was achieved. Although the tumor size had been stable since that time, she developed systemic myasthenia gravis 10 years after the proton therapy. Extended thymectomy was performed. There were no adhesions between the tumor and the pericardium, and there were no adhesions also between the tumor and the sternum, probably due to the favor of Bragg peak effect. Extensive hyalinization with small foci of viable tumor cells showing degenerated type A-like morphology was observed in the resected tumor. Whether the viable cells represented recurrence with degenerative changes or de novo tumor formation was unable to be determined, and whether the viable cells were responsible for the onset of myasthenia gravis remained unclear. PMID:25301055

  15. Study of air cavities influence in head and neck radiotherapy with 10 MV photon beam

    International Nuclear Information System (INIS)

    This is a study about dose distribution in the larynx region under irradiation with a 10 MV photon beam. This localization presents air cavities, that can compromise the dose at air-tissue interfaces by electronic equilibrium loss and backscattering lack. For this study, a parallel ionization chamber was used in the air cavities simulated with a perspex phantom. The influence of the air cavities in the proximal, distal and lateral interfaces was analysed. The results showed a expressive loss of dose at the air-tissue interface. For typical irradiation field and anatomic cavity, under dose values of 4% in the proximal interface, 11% in the distal interface and 7% in the lateral interface were found. Irradiation field larger than 6 X 6 cm2 were optimal in reducing the total effect of under dosing at the interface. (author). 39 refs, 23 figs, 12 tabs

  16. Induced photonuclear interaction by Rhodotron-TT200 10 MeV electron beam

    Indian Academy of Sciences (India)

    Farshid Tabbakh; Mojtaba Mostajab Aldaavati; Mahdieh Hoseyni; Khadijeh Rezaee Ebrahim Saraee

    2012-02-01

    In this paper the photonuclear interaction induced by 10 MeV electron beam generating high-intensity neutrons is studied. Since the results depend on the target material, the calculations are performed for Pb, Ta and W targets which have high , in a simple geometry. MCNPX code has been used to simulate the whole process. Also, the results of photon generation has been compared with the experimental results to evaluate the reliability of the calculation. The results show that the obtained neutron flux can reach up to 1012 n/cm2 /s with average energies of 0.9 MeV, 0.4 MeV and 0.9 MeV for these three elements respectively with the maximum heat deposited as 3000 W/c3,4500 W/c3 and 6000 W/c3.

  17. Inferring phytoplankton carbon and eco-physiological rates from diel cycles of spectral particulate beam-attenuation coefficient

    Directory of Open Access Journals (Sweden)

    G. Dall'Olmo

    2011-11-01

    Full Text Available The diurnal fluctuations in solar irradiance impose a fundamental frequency on ocean biogeochemistry. Observations of the ocean carbon cycle at these frequencies are rare, but could be considerably expanded by measuring and interpreting the inherent optical properties. A method is presented to analyze diel cycles in particulate beam-attenuation coefficient (cp measured at multiple wavelengths. The method is based on fitting observations with a size-structured population model coupled to an optical model to infer the particle size distribution and physiologically relevant parameters of the cells responsible for the measured diel cycle in cp. Results show that the information related to size and contained in the spectral data can be exploited to independently estimate growth and loss rates during the day and night. In addition, the model can characterize the population of particles affecting the diel variability in cp. Application of this method to spectral cp measured at a station in the oligotrophic Mediterranean Sea suggests that most of the observed variations in cp can be ascribed to a synchronized population of cells with an equivalent spherical diameter around 4.6±1.5 μm. The inferred carbon biomass of these cells was about 5.2–6.0 mg m−3 and accounted for approximately 10% of the total particulate organic carbon. If successfully validated, this method may improve our in situ estimates of primary productivity.

  18. Surface treatment of 0.20% C carbon steel by high-current pulsed electron beam

    Institute of Scientific and Technical Information of China (English)

    XU Guo-cheng; FU Shi-you; GUAN Qing-feng

    2006-01-01

    A high-current pulsed electron beam(HCPEB) generated on the system of Nadezhda-2 was applied to improve the microstructure and performance of 0.20% C low carbon steel. Surface layers of the samples bombarded by explosive electron beam at different pulses was observed by using electron microscopy. The physical model of the thermal-stress process and related modification mechanism as a result of HCPEB irradiation was also investigated. After HCPEB post treatments, obvious changes in microstructure and significant hardening occur in the depth of 200-250 μm from the surface after HCPEB irradiation. Rapid heating and subsequent rapid solidification induce heavy plastic deformation, which results in that the laminated structure of pearlite is substituted by dispersive rounded-like cementites in the near-surface. The effect of HCPEB treatment can reach more than 500 m depth from the surface. The original crystalline structure is changed to a different degree that grows with the numbers of bombardment, and in the surface layer amorphous states and nanocrystaline structures consisting of grains of γ-phase and cementite are found. The violent stress induced by HCPEB irradiation is the origin of the nanostructured and amorphous structure formation.

  19. Reactions of a Be-10 beam on proton and deuteron targets

    CERN Document Server

    Schmitt, K T; Ahn, S; Bardayan, D W; Bey, A; Blackmon, J C; Brown, S M; Chae, K Y; Chipps, K A; Cizewski, J A; Hahn, K I; Kolata, J J; Kozub, R L; Liang, J F; Matei, C; Matos, M; Matyas, D; Moazen, B; Nesaraja, C D; Nunes, F M; Malley, P D O; Pain, S D; Peters, W A; Pittman, S T; Roberts, A; Shapira, D; Shriner, J F; Smith, M S; Spassova, I; Stracener, D W; Upadhyay, N J; Villano, A N; Wilson, G L

    2013-01-01

    The extraction of detailed nuclear structure information from transfer reactions requires reliable, well-normalized data as well as optical potentials and a theoretical framework demonstrated to work well in the relevant mass and beam energy ranges. It is rare that the theoretical ingredients can be tested well for exotic nuclei owing to the paucity of data. The halo nucleus Be-11 has been examined through the 10Be(d,p) reaction in inverse kinematics at equivalent deuteron energies of 12,15,18, and 21.4 MeV. Elastic scattering of Be-10 on protons was used to select optical potentials for the analysis of the transfer data. Additionally, data from the elastic and inelastic scattering of Be-10 on deuterons was used to fit optical potentials at the four measured energies. Transfers to the two bound states and the first resonance in Be-11 were analyzed using the Finite Range ADiabatic Wave Approximation (FR-ADWA). Consistent values of the spectroscopic factor of both the ground and first excited states were extrac...

  20. Study of the time and space distribution of $\\beta^+$ emitters from $80\\ \\mega\\electronvolt/$u carbon ion beam irradiation on PMMA

    CERN Document Server

    Agodi, C; Cirrone, G A P; Collamati, F; Cuttone, G; De Lucia, E; De Napoli, M; Di Domenico, A; Faccini, R; Ferroni, F; Fiore, S; Gauzzi, P; Iarocci, E; Marafini, M; Mattei, I; Paoloni, A; Patera, V; Piersanti, L; Romano, F; Sarti, A; Sciubba, A; Voena, C

    2012-01-01

    Proton and carbon ion therapy is an emerging technique used for the treatment of solid cancers. The monitoring of the dose delivered during such treatments and the on-line knowledge of the Bragg peak position is still a matter of research. A possible technique exploits the collinear $511\\ \\kilo\\electronvolt$ photons produced by positrons annihilation from $\\beta^+$ emitters created by the beam. This paper reports rate measurements of the $511\\ \\kilo\\electronvolt$ photons emitted after the interactions of a $80\\ \\mega\\electronvolt / u$ fully stripped carbon ion beam at the Laboratori Nazionali del Sud (LNS) of INFN, with a Poly-methyl methacrylate target. The time evolution of the $\\beta^+$ rate was parametrized and the dominance of $^{11}C$ emitters over the other species ($^{13}N$, $^{15}O$, $^{14}O$) was observed, measuring the fraction of carbon ions activating $\\beta^+$ emitters $A_0=(10.3\\pm0.7)\\cdot10^{-3}$. The average depth in the PMMA of the positron annihilation from $\\beta^+$ emitters was also meas...

  1. Study of the time and space distribution of {beta}{sup +} emitters from 80MeV/u carbon ion beam irradiation on PMMA

    Energy Technology Data Exchange (ETDEWEB)

    Agodi, C. [Laboratori Nazionali del Sud dell' INFN, Catania (Italy); Bellini, F. [Dipartimento di Fisica, Sapienza Universita di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Cirrone, G.A.P. [Laboratori Nazionali del Sud dell' INFN, Catania (Italy); Collamati, F. [Dipartimento di Fisica, Sapienza Universita di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Cuttone, G. [Laboratori Nazionali del Sud dell' INFN, Catania (Italy); De Lucia, E. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); De Napoli, M. [Laboratori Nazionali del Sud dell' INFN, Catania (Italy); Di Domenico, A.; Faccini, R.; Ferroni, F. [Dipartimento di Fisica, Sapienza Universita di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Fiore, S. [Dipartimento di Fisica, Sapienza Universita di Roma, Roma (Italy); Gauzzi, P. [Dipartimento di Fisica, Sapienza Universita di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Iarocci, E. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Dipartimento di Scienze di Base e Applicate per l' Ingegneria, Sapienza Universita di Roma, Roma (Italy); Marafini, M., E-mail: michela.marafini@roma1.infn.it [Museo Storico della Fisica e Centro Studi e Ricerche ' E. Fermi' , Roma (Italy); Mattei, I. [Dipartimento di Fisica, Roma Tre Universita di Roma, Roma (Italy); Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Paoloni, A. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); and others

    2012-07-15

    Proton and carbon ion therapy is an emerging technique used for the treatment of solid cancers. The monitoring of the dose delivered during such treatments and the on-line knowledge of the Bragg peak position is still a matter of research. A possible technique exploits the collinear 511keV photons produced by positrons annihilation from {beta}{sup +} emitters created by the beam. This paper reports rate measurements of the 511keV photons emitted after the interactions of a 80MeV/u fully stripped carbon ion beam at the Laboratori Nazionali del Sud (LNS) of INFN, with a poly-methyl methacrylate target. The time evolution of the {beta}{sup +} rate was parametrized and the dominance of {sup 11}C emitters over the other species ({sup 13}N, {sup 15}O, {sup 14}O) was observed, measuring the fraction of carbon ions activating {beta}{sup +} emitters to be (10.3{+-}0.7) Multiplication-Sign 10{sup -3}. The average depth in the PMMA of the positron annihilation from {beta}{sup +} emitters was also measured, D{sub {beta}{sup +}}=5.3{+-}1.1mm, to be compared to the expected Bragg peak depth D{sub Bragg}=11.0{+-}0.5mm obtained from simulations.

  2. Design of a conveyor system for 500 keV/10 mA electron beam machine

    International Nuclear Information System (INIS)

    A design of Conveyor System of 500 keV/10 mA Electron Beam Machine was carried out. In an irradiation technique using Electron Beam Machine, a conveyor system i.e. an equipment for conveying samples, is required. The design included determination of the speed and width of the system. The doses absorbed by samples depend on the election beam current (I), samples speed (V) and width (W). The system was equipped with moving trails noted by an electric motor that its speed could be controlled according to be the dose and an interface so that it could be operated from a control room. From the design, the conveyor system could be constructed and operated in a 500 keV/10 mA Electron Beam Machine, for either sheet or contained samples (closed). (author)

  3. Simulation and optimization of a 10 A electron gun with electrostatic compression for the electron beam ion source

    International Nuclear Information System (INIS)

    Increasing the current density of the electron beam in the ion trap of the Electron Beam Ion Source (EBIS) in BNL's Relativistic Heavy Ion Collider facility would confer several essential benefits. They include increasing the ions’ charge states, and therefore, the ions’ energy out of the Booster for NASA applications, reducing the influx of residual ions in the ion trap, lowering the average power load on the electron collector, and possibly also reducing the emittance of the extracted ion beam. Here, we discuss our findings from a computer simulation of an electron gun with electrostatic compression for electron current up to 10 A that can deliver a high-current-density electron beam for EBIS. The magnetic field in the cathode-anode gap is formed with a magnetic shield surrounding the gun electrodes and the residual magnetic field on the cathode is (5 ÷ 6) Gs. It was demonstrated that for optimized gun geometry within the electron beam current range of (0.5 ÷ 10) A the amplitude of radial beam oscillations can be maintained close to 4% of the beam radius by adjusting the injection magnetic field generated by a separate magnetic coil. Simulating the performance of the gun by varying geometrical parameters indicated that the original gun model is close to optimum and the requirements to the precision of positioning the gun elements can be easily met with conventional technology.

  4. Simulation and optimization of a 10 A electron gun with electrostatic compression for the electron beam ion source

    Science.gov (United States)

    Pikin, A.; Beebe, E. N.; Raparia, D.

    2013-03-01

    Increasing the current density of the electron beam in the ion trap of the Electron Beam Ion Source (EBIS) in BNL's Relativistic Heavy Ion Collider facility would confer several essential benefits. They include increasing the ions' charge states, and therefore, the ions' energy out of the Booster for NASA applications, reducing the influx of residual ions in the ion trap, lowering the average power load on the electron collector, and possibly also reducing the emittance of the extracted ion beam. Here, we discuss our findings from a computer simulation of an electron gun with electrostatic compression for electron current up to 10 A that can deliver a high-current-density electron beam for EBIS. The magnetic field in the cathode-anode gap is formed with a magnetic shield surrounding the gun electrodes and the residual magnetic field on the cathode is (5 ÷ 6) Gs. It was demonstrated that for optimized gun geometry within the electron beam current range of (0.5 ÷ 10) A the amplitude of radial beam oscillations can be maintained close to 4% of the beam radius by adjusting the injection magnetic field generated by a separate magnetic coil. Simulating the performance of the gun by varying geometrical parameters indicated that the original gun model is close to optimum and the requirements to the precision of positioning the gun elements can be easily met with conventional technology.

  5. Integration of carbon nanotubes with semiconductor technology: fabrication of hybrid devices by III–V molecular beam epitaxy

    DEFF Research Database (Denmark)

    Stobbe, Søren; Lindelof, P. E.; Nygård, J.

    2006-01-01

    incorporation of singlewall nanotubes in III–V semiconductor heterostructures grown by molecular beam epitaxy (MBE). We demonstrate that singlewall carbon nanotubes can be overgrown using MBE; electrical contacts to the nanotubes are obtained by GaMnAs grown at 250 °C. The resulting devices can exhibit field...

  6. Investigations on the quality of treatment plans for carbon ion radiotherapy. Beam delivery systems and radiobiological models

    Energy Technology Data Exchange (ETDEWEB)

    Gillmann, Clarissa

    2014-07-01

    In a worldwide effort in research and development, radiation therapy with carbon ions has evolved to a technologically challenging but clinically very promising treatment option for cancer patients. To further improve patient benefit, optimal use of the physical and biological characteristics of carbon ions as well as of the available technologies should be made. The present thesis investigates the impact of different beam delivery systems and radiobiological models on the quality of treatment plans in carbon ion radiotherapy. The results of the study may provide pointers as to the role and the possible future implementation of the different techniques and radiobiological models in existing and upcoming particle therapy centers.

  7. RBEs of thermal neutron beam and the 10B(n,α)7Li reaction on skin in the hamster

    International Nuclear Information System (INIS)

    The skin relative biologic effectiveness (RBE) of a thermal neutron beam and the 10B(n,α)7Li reaction were determined by using Syrian (Golden) hamsters and compared with the RBE of a 9-MeV electron beam. The boron used in our experiment was 10B-paraboronophenylalanine (10B-BPA). The Kyoto University Research Reactor was used as the source of thermal neutrons. In the skin dose-response curve, thermal neutron beams produced an almost linear relationship between the maximum skin reaction and the absorbed dose. The RBE obtained in this experimental system was about 2.0. The RBEs of the 14N(n,p)14C and the 10B(n,α)7Li reaction were estimated as 3.1 and about 1.6, respectively, with the assumption that each component of radiation was additive

  8. One-dimensional carbon nanostructures for terahertz electron-beam radiation

    Science.gov (United States)

    Tantiwanichapan, Khwanchai; Swan, Anna K.; Paiella, Roberto

    2016-06-01

    One-dimensional carbon nanostructures such as nanotubes and nanoribbons can feature near-ballistic electronic transport over micron-scale distances even at room temperature. As a result, these materials provide a uniquely suited solid-state platform for radiation mechanisms that so far have been the exclusive domain of electron beams in vacuum. Here we consider the generation of terahertz light based on two such mechanisms, namely, the emission of cyclotronlike radiation in a sinusoidally corrugated nanowire (where periodic angular motion is produced by the mechanical corrugation rather than an externally applied magnetic field), and the Smith-Purcell effect in a rectilinear nanowire over a dielectric grating. In both cases, the radiation properties of the individual charge carriers are investigated via full-wave electrodynamic simulations, including dephasing effects caused by carrier collisions. The overall light output is then computed with a standard model of charge transport for two particularly suitable types of carbon nanostructures, i.e., zigzag graphene nanoribbons and armchair single-wall nanotubes. Relatively sharp emission peaks at geometrically tunable terahertz frequencies are obtained in each case. The corresponding output powers are experimentally accessible even with individual nanowires, and can be scaled to technologically significant levels using array configurations. These radiation mechanisms therefore represent a promising paradigm for light emission in condensed matter, which may find important applications in nanoelectronics and terahertz photonics.

  9. Increased Tensile Strength of Carbon Nanotube Yarns and Sheets through Chemical Modification and Electron Beam Irradiation

    Science.gov (United States)

    Miller, Sandi G.; Williams, Tiffany S.; Baker, James S.; Sola, Francisco; Lebron-Colon, Marisabel; McCorkle, Linda S.; Wilmoth, Nathan G.; Gaier, James; Chen, Michelle; Meador, Michael A.

    2014-01-01

    The inherent strength of individual carbon nanotubes offers considerable opportunity for the development of advanced, lightweight composite structures. Recent work in the fabrication and application of carbon nanotube (CNT) forms such as yarns and sheets has addressed early nanocomposite limitations with respect to nanotube dispersion and loading; and has pushed the technology toward structural composite applications. However, the high tensile strength of an individual CNT has not directly translated to macro-scale CNT forms where bulk material strength is limited by inter-tube electrostatic attraction and slippage. The focus of this work was to assess post processing of CNT sheet and yarn to improve the macro-scale strength of these material forms. Both small molecule functionalization and e-beam irradiation was evaluated as a means to enhance tensile strength and Youngs modulus of the bulk CNT material. Mechanical testing results revealed a tensile strength increase in CNT sheets by 57 when functionalized, while an additional 48 increase in tensile strength was observed when functionalized sheets were irradiated; compared to unfunctionalized sheets. Similarly, small molecule functionalization increased yarn tensile strength up to 25, whereas irradiation of the functionalized yarns pushed the tensile strength to 88 beyond that of the baseline yarn.

  10. Monte Carlo Calculations of Dose to Medium and Dose to Water for Carbon Ion Beams in Various Media

    DEFF Research Database (Denmark)

    Herrmann, Rochus; Petersen, Jørgen B.B.; Jäkel, Oliver;

    materials exposed to carbon ion beams. The scored track-length fluence spectrum Φi for a given particle i at the energy E, is multiplied with the mass stopping power for target material for calculating Dm . Similarly, Dw is calculated by multiplying the same fluence spectrum with the mass stopping power...... the PSTAR, ASTAR stopping power routines available at NIST1 and MSTAR2 provided by H. Paul et al. 3     Results For a pristine carbon ion beam we encountered a maximum deviation between Dw and Dm up to 8% for bone. In addition we investigate spread out Bragg peak configurations which dilutes the effect......1     Background In clinical practice the quantity dose to water (Dw ) is used as a reference standard for dosimeters and treatment planning systems. Treatment planning systems usually rely on analytical representation of the particle beam, which are normally expressed as dose with respect to water...

  11. Long-pulse neutral beam power supply system for LBL 20 kV, 10 A sources

    Energy Technology Data Exchange (ETDEWEB)

    Honey, V.J.; Baker, W.R.; Fitzgerald, M.L.

    1976-05-01

    A description is given of the power supplies and control system for the LBL 20 kV, 10 A, 10 sec long-pulse neutral beam source test facility, now in operation. Such sources are used in a number of existing and planned fusion power experiments.

  12. Radiosensitivity of pimonidazole-unlabelled intratumour quiescent cell population to γ-rays, accelerated carbon ion beams and boron neutron capture reaction.

    OpenAIRE

    Masunaga, S; Sakurai, Y.; Tanaka, H.; Hirayama, R; Matsumoto, Y; Uzawa, A; Suzuki, M.; Kondo, N; Narabayashi, M.; Maruhashi, A; Ono, K.

    2013-01-01

    [Objectives] To detect the radiosensitivity of intratumour quiescent (Q) cells unlabelled with pimonidazole to accelerated carbon ion beams and the boron neutron capture reaction (BNCR). [Methods] EL4 tumour-bearing C57BL/J mice received 5-bromo-2′-deoxyuridine (BrdU) continuously to label all intratumour proliferating (P) cells. After the administration of pimonidazole, tumours were irradiated with γ-rays, accelerated carbon ion beams or reactor neutron beams with the prior administration of...

  13. Effect of carbon content on the mechanical properties of 10Cr-5W ferritic steels

    International Nuclear Information System (INIS)

    The effect of carbon content on the microstructures, the tensile strength, creep strength and fracture toughness of 10Cr-5W ferritic steels containing from 0.02 to 0.13 mass% C is investigated. The low carbon steels possess the higher Ms temperature than the high carbon steels, so that the packet size of the martensite structure is larger in the low carbon steels. Both the FATT (fracture appearance transition temperature) and the USE (upper shelf energy) increase with decreasing carbon content. This means the decrease of toughness and the increase of ductility with decreasing carbon content. Fine precipitates of the Laves phase are observed in the martensite lath in all experimental steels after quality heat treatment. The tensile strength measured at 873 K has a tendency to increase with decreasing C content. But a certain amount of C is needed even in 5 W ferritic steels to keep the longer creep-rupture life under the lower stress level. (orig.)

  14. Gorsky effect and diffusion of carbon in grade VT1-0 titanium

    International Nuclear Information System (INIS)

    By means of transmitting electron microscopy one showed the presence of metastable phase formations on the basis of carbon related coherently to matrix in VT1-0 titanium. Within 300-550 deg C temperature range when conducting three-point bending testings one observe the Gorsky effect by carbon determined at reverse deformation of creep. One justified the techniques enabling to determine diffusion coefficient of intrusion impurity causing the Gorsky effect. Using that technique one determined the diffusion efficient coefficients of carbon within 300-550 deg C range in VT1-0 specimens with grain various size. It is shown that in the ultrafinely-grain state (grain size is about 0.3 μm) the grain-boundary diffusion is the basic mechanism of carbon diffusion. One determined activation energy values of grain-boundary and volume diffusion of carbon equal to 103 and 177 kJ/mole

  15. Measurement of large angle fragments induced by 400 MeV n-1 carbon ion beams

    Science.gov (United States)

    Aleksandrov, Andrey; Consiglio, Lucia; De Lellis, Giovanni; Di Crescenzo, Antonia; Lauria, Adele; Montesi, Maria Cristina; Patera, Vincenzo; Sirignano, Chiara; Tioukov, Valeri

    2015-09-01

    The use of carbon ion beams in radiotherapy presents significant advantages when compared to traditional x-ray. In fact, carbon ions deposit their energy inside the human body at the end of their range, the Bragg peak. Unlike x-ray beams, where the energy deposition decreases exponentially inside the irradiated volume, the shape of carbon beams is sharp and focused. Advantages are an increased energy released in the cancer volume while minimizing the irradiation to healthy tissues. Currently, the use of carbon beams is limited by the poor knowledge we have about the effects of the secondary fragments on the irradiated tissues. The secondary particles produced and their angular distribution is crucial to determine the global dose deposition. The knowledge of the flux of secondary particles plays a key role in the real time monitoring of the dose profile in hadron therapy. We present a detector based on nuclear emulsions for fragmentation measurements that performs a sub-micrometric tridimensional spatial resolution, excellent multi-particle separation and large angle track recognition. Nuclear emulsions are assembled in order to realize a hybrid detector (emulsion cloud chamber (ECC)) made of 300 μm nuclear emulsion films alternated with lead as passive material. Data reported here have been obtained by exposing two ECC detectors to the fragments produced by a 400 MeV n-1 12C beam on a composite target at the GSI laboratory in Germany. The ECC was exposed inside a more complex detector, named FIRST, in order to collect fragments with a continuous angular distribution in the range 47°-81° with respect to the beam axis. Results on the angular distribution of fragments as well as their momentum estimations are reported here.

  16. Measurement of large angle fragments induced by 400 MeV n−1 carbon ion beams

    International Nuclear Information System (INIS)

    The use of carbon ion beams in radiotherapy presents significant advantages when compared to traditional x-ray. In fact, carbon ions deposit their energy inside the human body at the end of their range, the Bragg peak. Unlike x-ray beams, where the energy deposition decreases exponentially inside the irradiated volume, the shape of carbon beams is sharp and focused. Advantages are an increased energy released in the cancer volume while minimizing the irradiation to healthy tissues. Currently, the use of carbon beams is limited by the poor knowledge we have about the effects of the secondary fragments on the irradiated tissues. The secondary particles produced and their angular distribution is crucial to determine the global dose deposition. The knowledge of the flux of secondary particles plays a key role in the real time monitoring of the dose profile in hadron therapy.We present a detector based on nuclear emulsions for fragmentation measurements that performs a sub-micrometric tridimensional spatial resolution, excellent multi-particle separation and large angle track recognition. Nuclear emulsions are assembled in order to realize a hybrid detector (emulsion cloud chamber (ECC)) made of 300 μm nuclear emulsion films alternated with lead as passive material.Data reported here have been obtained by exposing two ECC detectors to the fragments produced by a 400 MeV n−1 12C beam on a composite target at the GSI laboratory in Germany. The ECC was exposed inside a more complex detector, named FIRST, in order to collect fragments with a continuous angular distribution in the range 47°–81° with respect to the beam axis. Results on the angular distribution of fragments as well as their momentum estimations are reported here. (paper)

  17. Development and characterization of a 2D scintillation detector for quality assurance in scanned carbon ion beams

    Science.gov (United States)

    Tamborini, A.; Raffaele, L.; Mirandola, A.; Molinelli, S.; Viviani, C.; Spampinato, S.; Ciocca, M.

    2016-04-01

    At the Centro Nazionale di Adroterapia Oncologica (CNAO Foundation), a two-dimensional high resolution scintillating dosimetry system has been developed and tested for daily Quality Assurance measurements (QA) in carbon ion radiotherapy with active scanning technique, for both single pencil beams and scanned fields produced by a synchrotron accelerator. The detector consists of a thin plane organic scintillator (25×25 cm2, 2 mm thick) coupled with a high spatial resolution CCD camera (0.25 mm) in a light-tight box. A dedicated Labview software was developed for image acquisition triggered with the beam extraction, data post-processing and analysis. The scintillator system was preliminary characterized in terms of short-term reproducibility (found to be within±0.5%), linearity with the number of particles (linear fit χ2 = 0.996) and dependence on particle flux (measured to be < 1.5 %). The detector was then tested for single beam spot measurements (Full Width at Half Maximum and position) and for 6×6 cm2 reference scanned field (determination of homogeneity) for carbon ions with energy from 115 MeV/u up to 400 MeV/u. No major differences in the investigated beam parameters measured with scintillator system and the radiochromic EBT3 reference films were observed. The system allows therefore real-time monitoring of the carbon ion beam relevant parameters, with a significant daily time saving with respect to films currently used. The results of this study show the suitability of the scintillation detector for daily QA in a carbon ion facility with an active beam delivery system.

  18. Measurement of analyzing power for proton-carbon elastic scattering in the Coulomb-nuclear interference region with a 22-GeV/c polarized proton beam

    International Nuclear Information System (INIS)

    The analyzing power for proton-carbon elastic scattering in the Coulomb-nuclear interference region of momentum transfer, 9.0x10-3-2 (GeV/c)2, was measured with a 21.7 GeV/c polarized proton beam at the Alternating Gradient Synchrotron of Brookhaven National Laboratory. The ratio of hadronic spin-flip to nonflip amplitude, r5, was obtained from the analyzing power to be Rer5=0.088±0.058 and Imr5=-0.161±0.226

  19. Investigation of the dosimetric impact of a Ni-Ti fiducial marker in carbon ion and proton beams

    International Nuclear Information System (INIS)

    Introduction. Fiducial markers based on a removable stent are currently used in image guided radiotherapy. Here it is investigated what the possible dosimetric impact of such a marker could be, if used in proton or carbon ion treatment. Material and methods. The simulations have been done using the Monte Carlo particle transport code FLUKA with its default hadron therapy settings. A 3 cm long stent is approximated in FLUKA by stacking hollow tori. To simulate realistic clinical conditions a field 5 x 5 cm has been used, delivering a 5 cm wide spread out Bragg peak located 5 cm deep for protons and carbon ions. For protons fields mimicking active and passive beam delivery have been investigated. The stent has been arranged perpendicular, turned 45 degrees, and parallel to the beam axis. Results. The position of the 95% dose level shifts for carbon ions 7 mm in proximal direction for the marker perpendicular to the beam and 8 mm if the stent is turned 45 degree for a 1 x 1 cm dose binning on the centre beam axis. For the case where the stent was parallel to beam direction the 95% dose level shifts 26 mm. For active delivered protons, the shift of the 95% dose level is less. The shift for a perpendicular arranged marker is 6 mm, for 45 degrees turned it is 7 mm. For the case where the stent was oriented parallel to the beam, the observed shift is 21 mm. Dose inhomogeneities caused by straggling effects occur only near the distal edge of the field. Conclusions. The results of our investigations show that the Ni-Ti marker has a non negligible impact on the dose distributions for the used radiation types. However if the treatment plan rules out narrow angles between symmetry axis of the stent and the beam direction, this may be compensated.

  20. Chemical effects of 100 keV primary electrons in an e-beam sustained carbon dioxide laser discharge

    International Nuclear Information System (INIS)

    The dissociation of carbon dioxide and the reaction of carbon monoxide with oxygen caused by a high-energy (approx 100 kev) electron beam in a typical carbon dioxide laser gas mixture has been observed. The variation of reaction rates with electron energy and current, interelectrode spacing, and gas composition has been studied. The rates of both processes suggest that the reactions are caused by unthermalized secondary electrons. The conditions were investigated under which the carbon monoxide oxidation reaction could be used to offset dissociation in a laser and thus prolong its sealed life. For a secondary to primary current ratio of one hundred this condition should be satisfied for any practical device. A sealed run was carried out which demonstrated that dissociation by secondary electrons could be offset by the oxidation of carbon monoxide by the primary electrons. (author)

  1. Robust, easily shaped, and epoxy-free carbon-fiber-aluminum cathodes for generating high-current electron beams

    Science.gov (United States)

    Liu, Lie; Li, Limin; Wen, Jianchun; Wan, Hong

    2009-02-01

    This paper presents the construction of carbon-fiber-aluminum (CFA) cathode by squeezing casting and its applications for generating high-current electron beams to drive high-power microwave sources. The fabrication process avoided using epoxy, a volatile deteriorating the vacuum system. These cathodes had a higher hardness than conventional aluminum, facilitating machining. After surface treatment, carbon fibers became the dominator determining emission property. A multineedle CFA cathode was utilized in a triode virtual cathode oscillator (vircator), powered by a ˜450 kV, ˜400 ns pulse. It was found that 300-400 MW, ˜250 ns microwave was radiated at a dominant frequency of 2.6 GHz. Further, this cathode can endure high-current-density emission without detectable degradation in performance as the pulse shot proceeded, showing the robust nature of carbon fibers as explosive emitters. Overall, this new class of cold cathodes offers a potential prospect of developing high-current electron beam sources.

  2. Dynamic response of RC beams strengthened with near surface mounted Carbon-FRP rods subjected to damage

    Science.gov (United States)

    Capozucca, R.; Blasi, M. G.; Corina, V.

    2015-07-01

    Near surface mounted (NSM) technique with fiber reinforced polymer (FRP) is becoming a common method in the strengthening of concrete beams. The availability of NSM FRP technique depends on many factors linked to materials and geometry - dimensions of the rods used, type of FRP material employed, rods’ surface configuration, groove size - and to adhesion between concrete and FRP rods. In this paper detection of damage is investigated measuring the natural frequency values of beam in the case of free-free ends. Damage was due both to reduction of adhesion between concrete and carbon-FRP rectangular and circular rods and cracking of concrete under static bending tests on beams. Comparison between experimental and theoretical frequency values evaluating frequency changes due to damage permits to monitor actual behaviour of RC beams strengthened by NSM CFRP rods.

  3. Generation and diagnostics of pulsed intense ion beams with an energy density of 10 J/cm2

    International Nuclear Information System (INIS)

    The paper presents the results of a study on transportation and focusing of a pulsed ion beam at gigawatt power level, generated by a diode with explosive-emission cathode. The experiments were carried out with the TEMP-4M accelerator operating in double-pulse mode: the first pulse is of negative polarity (500 ns, 100-150 kV), and this is followed by a second pulse of positive polarity (120 ns, 200-250 kV). To reduce the beam divergence, we modified the construction of the diode. The width of the anode was increased compared to that of the cathode. We studied different configurations of planar and focusing strip diodes. It was found that the divergence of the ion beam formed by a planar strip diode, after construction modification, does not exceed 3° (half-angle). Modification to the construction of a focusing diode made it possible to reduce the beam divergence from 8° to 4°-5°, as well as to increase the energy density at the focus up to 10-12 J/cm2, and decrease the shot to shot variation in the energy density from 10%-15% to 5%-6%. When measuring the ion beam energy density above the ablation threshold of the target material (3.5-4 J/cm2), we used a metal mesh with 50% transparency to lower the energy density. The influence of the metal mesh on beam transport has been studied

  4. Beam pen lithography based on arrayed polydimethylsiloxane (PDMS) micro-pyramids spin-coated with carbon black photo-resist

    International Nuclear Information System (INIS)

    This paper presents a new method for preparing a polydimethylsiloxane (PDMS) mold which can be used in beam pen lithography for patterning a photo-resist (PR) layer in a maskless and direct-write manner. The PDMS mold contains an array of micro-pyramids on its surface and is spin-coated with a layer of carbon black PR which is an opaque material. Because of the arrayed pyramidal surface profile, the spin-coated carbon black PR layer is either thinner at the pyramid tips or does not cover the tips at all, which allows ultraviolet (UV) light to pass through the PDMS mold and forms an array of UV beams. The aperture size of the UV beams can be controlled at a sub-micrometer scale and hence can be used for micro/nano-patterning. Applying this carbon black-PR-coated PDMS mold in beam pen lithography along with a metal lift-off process, various metal dot patterns with a dot-size around 400 to 500 nm are successfully obtained. Both experimental results and theoretical analysis are given along with possible improvements and applications in the future. (paper)

  5. Secondary organic carbon quantification and source apportionment of PM10 in Kaifeng, China

    Institute of Scientific and Technical Information of China (English)

    WU Lin; FENG Yinchang; WU Jianhui; ZHU Tan; BI Xiaohui; HAN Bo; YANG Weihong; YANG Zhiqiang

    2009-01-01

    During 2005, the filter samples of ambient PM10 from five sites and the source samples of particulate matter were collected in Kaifeng, Henan province of China. Nineteen elements, water-soluble ions, total carbon (TC) and organic carbon (OC) contained in samples were analyzed. Seven contributive source types were identified and their contributions to ambient PM10 were estimated by chemical mass balance (CMB) receptor model. Weak associations between the concentrations of organic carbon and element carbon (EC) were observed during the sampling periods, indicating that there was secondary organic aerosol pollution in the urban atmosphere. An indirect method of "OC/EC minimum ratio" was applied to estimate the concentration of secondary organic carbon (SOC). The results showed that SOC contributed 26.2%, 32.4% and 18.0% of TC in spring, summer-fall and winter respectively, and the annual average SOC concentration was 7.07 μg/m3, accounting for 5.73% of the total mass in ambient PM10. The carbon species concentrations in ambient PM10 were recalculated by subtracting the SOC concentrations from measured concentrations of TC and OC to increase the compatibility of source and receptor measurements for CMB model.

  6. Structural changes of electron and ion beam-deposited contacts in annealed carbon-based electrical devices

    KAUST Repository

    Batra, Nitin M

    2015-10-09

    The use of electron and ion beam deposition to make devices containing discrete nanostructures as interconnectors is a well-known nanofabrication process. Classically, one-dimensional materials such as carbon nanotubes (CNTs) have been electrically characterized by resorting to these beam deposition methods. While much attention has been given to the interconnectors, less is known about the contacting electrodes (or leads). In particular, the structure and chemistry of the electrode–interconnector interface is a topic that deserves more attention, as it is critical to understand the device behavior. Here, the structure and chemistry of Pt electrodes, deposited either with electron or ion beams and contacted to a CNT, are analyzed before and after thermally annealing the device in a vacuum. Free-standing Pt nanorods, acting as beam-deposited electrode models, are also characterized pre- and post-annealing. Overall, the as-deposited leads contain a non-negligible amount of amorphous carbon that is consolidated, upon heating, as a partially graphitized outer shell enveloping a Pt core. This observation raises pertinent questions regarding the definition of electrode–nanostructure interfaces in electrical devices, in particular long-standing assumptions of metal-CNT contacts fabricated by direct beam deposition methods.

  7. Structural changes of electron and ion beam-deposited contacts in annealed carbon-based electrical devices

    Science.gov (United States)

    Batra, Nitin M.; Patole, Shashikant P.; Abdelkader, Ahmed; Anjum, Dalaver H.; Deepak, Francis L.; Costa, Pedro M. F. J.

    2015-11-01

    The use of electron and ion beam deposition to make devices containing discrete nanostructures as interconnectors is a well-known nanofabrication process. Classically, one-dimensional materials such as carbon nanotubes (CNTs) have been electrically characterized by resorting to these beam deposition methods. While much attention has been given to the interconnectors, less is known about the contacting electrodes (or leads). In particular, the structure and chemistry of the electrode-interconnector interface is a topic that deserves more attention, as it is critical to understand the device behavior. Here, the structure and chemistry of Pt electrodes, deposited either with electron or ion beams and contacted to a CNT, are analyzed before and after thermally annealing the device in a vacuum. Free-standing Pt nanorods, acting as beam-deposited electrode models, are also characterized pre- and post-annealing. Overall, the as-deposited leads contain a non-negligible amount of amorphous carbon that is consolidated, upon heating, as a partially graphitized outer shell enveloping a Pt core. This observation raises pertinent questions regarding the definition of electrode-nanostructure interfaces in electrical devices, in particular long-standing assumptions of metal-CNT contacts fabricated by direct beam deposition methods.

  8. Construction and Testing of Window System of 350 keV/10 mA Electron Beam Machine

    International Nuclear Information System (INIS)

    The construction and testing of window system of 350 keV/10 mA electron beam machine have been carried out. The function of the window is to separate vacuum chamber of electron beam machine from atmosphere and pass the electron beam from electron gun to the target. The design of window system consist of scanning horn flange, intermediate flange, supporting flange, gasket holder, made of pure aluminium wire material and cooling nozzle. To obtain high vacuum, the pure aluminium wire gasket should be used. But in vacuum testing the pure aluminium wire gasket was replaced with viton and titanium foil window of 50 μm was replaced with bronze plate. Theoretically the loss of energy of 500 keV electron beam at window is 33.32 keV. So that the 20 mA electron beam current will produce power dissipation of 665.2 Watt. For cooling the power dissipation the air speed of 41.553 m/sec is blown to the window surface. Blower with capacity of 0.167 m3/sec was used in this experiment, so that the nozzle around of 3.35 mm is applied. The result of test indicates that the optimal vacuum 5x10-5 mbar was reached, this result was close to the used diffusion pump capacity that is 3.5x10-5 mbar. It can be concluded that there is no leakage on the window construction. (author)

  9. Measurement of the νμ charged current quasielastic cross section on carbon with the T2K on-axis neutrino beam

    Science.gov (United States)

    Abe, K.; Adam, J.; Aihara, H.; Andreopoulos, C.; Aoki, S.; Ariga, A.; Assylbekov, S.; Autiero, D.; Barbi, M.; Barker, G. J.; Barr, G.; Bartet-Friburg, P.; Bass, M.; Batkiewicz, M.; Bay, F.; Berardi, V.; Berger, B. E.; Berkman, S.; Bhadra, S.; Blaszczyk, F. d. M.; Blondel, A.; Bolognesi, S.; Bordoni, S.; Boyd, S. B.; Brailsford, D.; Bravar, A.; Bronner, C.; Buchanan, N.; Calland, R. G.; Caravaca Rodríguez, J.; Cartwright, S. L.; Castillo, R.; Catanesi, M. G.; Cervera, A.; Cherdack, D.; Chikuma, N.; Christodoulou, G.; Clifton, A.; Coleman, J.; Coleman, S. J.; Collazuol, G.; Connolly, K.; Cremonesi, L.; Dabrowska, A.; Danko, I.; Das, R.; Davis, S.; de Perio, P.; De Rosa, G.; Dealtry, T.; Dennis, S. R.; Densham, C.; Dewhurst, D.; Di Lodovico, F.; Di Luise, S.; Dolan, S.; Drapier, O.; Duffy, K.; Dumarchez, J.; Dytman, S.; Dziewiecki, M.; Emery-Schrenk, S.; Ereditato, A.; Escudero, L.; Ferchichi, C.; Feusels, T.; Finch, A. J.; Fiorentini, G. A.; Friend, M.; Fujii, Y.; Fukuda, Y.; Furmanski, A. P.; Galymov, V.; Garcia, A.; Giffin, S.; Giganti, C.; Gilje, K.; Goeldi, D.; Golan, T.; Gonin, M.; Grant, N.; Gudin, D.; Hadley, D. R.; Haegel, L.; Haesler, A.; Haigh, M. D.; Hamilton, P.; Hansen, D.; Hara, T.; Hartz, M.; Hasegawa, T.; Hastings, N. C.; Hayashino, T.; Hayato, Y.; Hearty, C.; Helmer, R. L.; Hierholzer, M.; Hignight, J.; Hillairet, A.; Himmel, A.; Hiraki, T.; Hirota, S.; Holeczek, J.; Horikawa, S.; Hosomi, F.; Huang, K.; Ichikawa, A. K.; Ieki, K.; Ieva, M.; Ikeda, M.; Imber, J.; Insler, J.; Irvine, T. J.; Ishida, T.; Ishii, T.; Iwai, E.; Iwamoto, K.; Iyogi, K.; Izmaylov, A.; Jacob, A.; Jamieson, B.; Jiang, M.; Johnson, S.; Jo, J. H.; Jonsson, P.; Jung, C. K.; Kabirnezhad, M.; Kaboth, A. C.; Kajita, T.; Kakuno, H.; Kameda, J.; Kanazawa, Y.; Karlen, D.; Karpikov, I.; Katori, T.; Kearns, E.; Khabibullin, M.; Khotjantsev, A.; Kielczewska, D.; Kikawa, T.; Kilinski, A.; Kim, J.; King, S.; Kisiel, J.; Kitching, P.; Kobayashi, T.; Koch, L.; Koga, T.; Kolaceke, A.; Konaka, A.; Kopylov, A.; Kormos, L. L.; Korzenev, A.; Koshio, Y.; Kropp, W.; Kubo, H.; Kudenko, Y.; Kurjata, R.; Kutter, T.; Lagoda, J.; Lamont, I.; Larkin, E.; Laveder, M.; Lawe, M.; Lazos, M.; Lindner, T.; Lister, C.; Litchfield, R. P.; Longhin, A.; Lopez, J. P.; Ludovici, L.; Magaletti, L.; Mahn, K.; Malek, M.; Manly, S.; Marino, A. D.; Marteau, J.; Martin, J. F.; Martins, P.; Martynenko, S.; Maruyama, T.; Matveev, V.; Mavrokoridis, K.; Mazzucato, E.; McCarthy, M.; McCauley, N.; McFarland, K. S.; McGrew, C.; Mefodiev, A.; Metelko, C.; Mezzetto, M.; Mijakowski, P.; Miller, C. A.; Minamino, A.; Mineev, O.; Missert, A.; Miura, M.; Moriyama, S.; Mueller, Th. A.; Murakami, A.; Murdoch, M.; Murphy, S.; Myslik, J.; Nakadaira, T.; Nakahata, M.; Nakamura, K. G.; Nakamura, K.; Nakayama, S.; Nakaya, T.; Nakayoshi, K.; Nantais, C.; Nielsen, C.; Nirkko, M.; Nishikawa, K.; Nishimura, Y.; Nowak, J.; O'Keeffe, H. M.; Ohta, R.; Okumura, K.; Okusawa, T.; Oryszczak, W.; Oser, S. M.; Ovsyannikova, T.; Owen, R. A.; Oyama, Y.; Palladino, V.; Palomino, J. L.; Paolone, V.; Payne, D.; Perevozchikov, O.; Perkin, J. D.; Petrov, Y.; Pickard, L.; Pinzon Guerra, E. S.; Pistillo, C.; Plonski, P.; Poplawska, E.; Popov, B.; Posiadala-Zezula, M.; Poutissou, J.-M.; Poutissou, R.; Przewlocki, P.; Quilain, B.; Radicioni, E.; Ratoff, P. N.; Ravonel, M.; Rayner, M. A. M.; Redij, A.; Reeves, M.; Reinherz-Aronis, E.; Riccio, C.; Rodrigues, P. A.; Rojas, P.; Rondio, E.; Roth, S.; Rubbia, A.; Ruterbories, D.; Rychter, A.; Sacco, R.; Sakashita, K.; Sánchez, F.; Sato, F.; Scantamburlo, E.; Scholberg, K.; Schoppmann, S.; Schwehr, J.; Scott, M.; Seiya, Y.; Sekiguchi, T.; Sekiya, H.; Sgalaberna, D.; Shah, R.; Shaker, F.; Shaw, D.; Shiozawa, M.; Short, S.; Shustrov, Y.; Sinclair, P.; Smith, B.; Smy, M.; Sobczyk, J. T.; Sobel, H.; Sorel, M.; Southwell, L.; Stamoulis, P.; Steinmann, J.; Still, B.; Suda, Y.; Suzuki, A.; Suzuki, K.; Suzuki, S. Y.; Suzuki, Y.; Tacik, R.; Tada, M.; Takahashi, S.; Takeda, A.; Takeuchi, Y.; Tanaka, H. K.; Tanaka, H. A.; Tanaka, M. M.; Terhorst, D.; Terri, R.; Thompson, L. F.; Thorley, A.; Tobayama, S.; Toki, W.; Tomura, T.; Totsuka, Y.; Touramanis, C.; Tsukamoto, T.; Tzanov, M.; Uchida, Y.; Vacheret, A.; Vagins, M.; Vasseur, G.; Wachala, T.; Wakamatsu, K.; Walter, C. W.; Wark, D.; Warzycha, W.; Wascko, M. O.; Weber, A.; Wendell, R.; Wilkes, R. J.; Wilking, M. J.; Wilkinson, C.; Williamson, Z.; Wilson, J. R.; Wilson, R. J.; Wongjirad, T.; Yamada, Y.; Yamamoto, K.; Yanagisawa, C.; Yano, T.; Yen, S.; Yershov, N.; Yokoyama, M.; Yoo, J.; Yoshida, K.; Yuan, T.; Yu, M.; Zalewska, A.; Zalipska, J.; Zambelli, L.; Zaremba, K.; Ziembicki, M.; Zimmerman, E. D.; Zito, M.; Żmuda, J.; T2K Collaboration

    2015-06-01

    We report a measurement of the νμ charged current quasielastic cross-sections on carbon in the T2K on-axis neutrino beam. The measured charged current quasielastic cross-sections on carbon at mean neutrino energies of 1.94 GeV and 0.93 GeV are (11.95 ±0.19 (stat)-1.47+1.82(syst))×1 0-39 cm2/neutron , and (10.64 ±0.37 (stat)-1.65+2.03(syst))×1 0-39 cm2/neutron , respectively. These results agree well with the predictions of neutrino interaction models. In addition, we investigated the effects of the nuclear model and the multi-nucleon interaction.

  10. Zn-10.2% Fe coating over carbon steel atmospheric corrosion resistance. Comparison with zinc coating

    International Nuclear Information System (INIS)

    Zn-10.2% Fe galvanized coating versus hot galvanized coating over carbon steel corrosion performance has been studied. Different periods of atmospheric exposures in various Valencia Community sites, and salt spray accelerated test have been done. Carbon steel test samples have been used simultaneously in order to classify exposure atmosphere corrosivity, and environmental exposure atmosphere characteristics have been analyzed. Corrosion Velocity versus environmental parameters has been obtained. (Author) 17 refs

  11. Characterization of nanometer-scale porosity in reservoir carbonate rock by focused ion beam-scanning electron microscopy.

    Science.gov (United States)

    Bera, Bijoyendra; Gunda, Naga Siva Kumar; Mitra, Sushanta K; Vick, Douglas

    2012-02-01

    Sedimentary carbonate rocks are one of the principal porous structures in natural reservoirs of hydrocarbons such as crude oil and natural gas. Efficient hydrocarbon recovery requires an understanding of the carbonate pore structure, but the nature of sedimentary carbonate rock formation and the toughness of the material make proper analysis difficult. In this study, a novel preparation method was used on a dolomitic carbonate sample, and selected regions were then serially sectioned and imaged by focused ion beam-scanning electron microscopy. The resulting series of images were used to construct detailed three-dimensional representations of the microscopic pore spaces and analyze them quantitatively. We show for the first time the presence of nanometer-scale pores (50-300 nm) inside the solid dolomite matrix. We also show the degree of connectivity of these pores with micron-scale pores (2-5 μm) that were observed to further link with bulk pores outside the matrix. PMID:22214656

  12. Cell survival in carbon beams - comparison of amorphous track model predictions

    DEFF Research Database (Denmark)

    Grzanka, L.; Greilich, S.; Korcyl, M.;

    Introduction: Predictions of the radiobiological effectiveness (RBE) play an essential role in treatment planning with heavy charged particles. Amorphous track models ( [1] , [2] , also referred to as track structure models) provide currently the most suitable description of cell survival under i....... Amorphous track modelling of luminescence detector efficiency in proton and carbon beams. 4.Tsuruoka C, Suzuki M, Kanai T, et al. LET and ion species dependence for cell killing in normal human skin fibroblasts. Radiat Res. 2005;163:494-500.......Introduction: Predictions of the radiobiological effectiveness (RBE) play an essential role in treatment planning with heavy charged particles. Amorphous track models ( [1] , [2] , also referred to as track structure models) provide currently the most suitable description of cell survival under ion...... factors is the normalization of the energy distribution around the particle tracks to the actual LET value. Later on we check what is the effect of radial dose distribution choice on kappa parameter for different types and energy of ions. Outline References 1.Katz R, Sharma SC.Response of cells to fast...

  13. Optical properties of ion-beam-deposited ion-modified diamondlike (a-C:H) carbon

    International Nuclear Information System (INIS)

    Diamondlike carbon (DLC) is a hard, semitransparent material usually containing varying amounts of hydrogen. These materials have numerous potential applications, including use as coatings for infrared optics, and as such, the effects of damaging irradiation is of practical interest. In this paper we present results of variable angle spectroscopic ellipsometric (VASE) studies of ion-beam-deposited DLC films. These films have been further modified by directing 1-MeV gold ions, as well as 6.4-MeV fluorine ions, through the DLC and into the underlying silicon substrates, and the percentage of hydrogen in the film was measured versus fluence using proton recoil analysis. Optical analysis was performed assuming the Lorentz oscillator model. Three versions were used: one oscillator, two oscillator (with one fixed in energy), and two oscillator with all parameter variable. The latter model fits the VASE data extremely well, and the two oscillators can be interpreted as involving π to π* and σ to σ* band transitions. With ion modification the oscillators shift to lower photon energy, consistent with reduction in hydrogen concentration and possible increased graphitization

  14. Spatial fragment distribution from a therapeutic pencil-like carbon beam in water

    International Nuclear Information System (INIS)

    The latest heavy ion therapy tends to require information about the spatial distribution of the quality of radiation in a patient's body in order to make the best use of any potential advantage of swift heavy ions for the therapeutic treatment of a tumour. The deflection of incident particles is described well by Moliere's multiple-scattering theory of primary particles; however, the deflection of projectile fragments is not yet thoroughly understood. This paper reports on our investigation of the spatial distribution of fragments produced from a therapeutic carbon beam through nuclear reactions in thick water. A ΔE-E counter telescope system, composed of a plastic scintillator, a gas-flow proportional counter and a BGO scintillator, was rotated around a water target in order to measure the spatial distribution of the radiation quality. The results revealed that the observed deflection of fragment particles exceeded the multiple scattering effect estimated by Moliere's theory. However, the difference can be sufficiently accounted for by considering one term involved in the multiple-scattering formula; this term corresponds to a lateral 'kick' at the point of production of the fragment. This kick is successfully explained as a transfer of the intra-nucleus Fermi momentum of a projectile to the fragment; the extent of the kick obeys the expectation derived from the Goldhaber model

  15. Flexural behaviour of partially bonded carbon fibre reinforced polymers strengthened concrete beams: Application to fire protection systems design

    International Nuclear Information System (INIS)

    Highlights: • The mechanical behaviour of partially bonded CFRP strengthened beams was modelled. • Two dimensional non-linear finite element models were developed. • Partially bonded beams can present similar flexural strength to fully bonded ones. • Relations between the bonded length and the strength reduction were proposed. • The proposed relations were used for the design of fire protection systems. - Abstract: Recent fire resistance tests on reinforced concrete (RC) beams strengthened with carbon fibre reinforced polymers (CFRP) laminates showed that it is possible to attain considerable fire endurance provided that thermal insulation is applied at the anchorage zones of the strengthening system. With such protection, although the CFRP laminate prematurely debonds in the central part of the beam, it transforms into a cable fixed at the extremities until one of the anchorage zones loses its bond strength. The main objective of this paper is to propose a simplified methodology for the design of fire protection systems for CFRP strengthened-RC beams, which is based on applying thicker insulation at the anchorage zones (promoting the above mentioned “cable behaviour”) and a thinner one at the current zone (avoiding tensile rupture of the carbon fibres). As a first step towards the validation of this methodology, finite element (FE) models were developed to simulate the flexural behaviour at ambient temperature of full-scale RC beams strengthened with CFRP laminates according to the externally bonded reinforcement (EBR) and near surface mounted (NSM) techniques, in both cases fully or partially bonded (the latter simulating the cable). The FE models were calibrated with results of 4-point bending tests on small-scale beams and then extended for different beam geometries, with spans (L) varying from 2 m to 5 m, in which the influence of the CFRP bonded length (lb) and the loading type (point or uniformly distributed) on the strength reduction was

  16. Water equivalent thickness values of materials used in beams of protons, helium, carbon and iron ions

    OpenAIRE

    Zhang, Rui; Taddei, Phillip J.; Fitzek, Markus M.; Newhauser, Wayne D.

    2010-01-01

    Heavy charged particle beam radiotherapy for cancer is of increasing interest because it delivers a highly conformal radiation dose to the target volume. Accurate knowledge of the range of a heavy charged particle beam after it penetrates a patient’s body or other materials in the beam line is very important and is usually stated in terms of the water equivalent thickness (WET). However, methods of calculating WET for heavy charged particle beams are lacking. Our objective was to test several...

  17. Production of megavolt neutron beams with a relative energy spread of ∼ 5 x 10-4

    International Nuclear Information System (INIS)

    A method is described for producing megavolt neutron beams with a relative energy spread of ∼ 5 x 10-4, based on the use of an electrostatic accelerator and a gas target with no foil, making it possible to carry out continuous, controlled production of the working substance. In the target differential pumping of the vapor of the working substance is effected by freezing out in liquid-nitrogen condensers. A method has been developed for using beams of neutrons from the 12C(d,n) reaction to measure the total cross sections for the interaction of neutrons with nuclei and the differential cross sections for elastic scattering

  18. Optimizing the e-beam profile of a single carbon nanotube field emission device for electric propulsion systems

    Directory of Open Access Journals (Sweden)

    Juliano Fujioka Mologni

    2010-04-01

    Full Text Available Preliminary studies on field emission (FE arrays comprised of carbon nanotubes (CNT as an electron source for electric propulsion system show remarkably promising results. Design parameters for a carbon nanotube (CNT field-emission device operating on triode configuration were numerically simulated and optimized in order to enhance the e-beam focusing quality. An additional focus gate (FG was integrated to the device to control the profile of the emitted e-beam. An axisymmetric finite element model was developed to calculate the electric field distribution on the vacuum region and a modified Fowler-Nordheim (FN equation was used to evaluate the current density emission and the effective emitter area. Afterward, a FE simulation was employed in order to calculate the trajectory of the emitted electrons and define the electron-optical properties of the e-beam. The integration of the FG was fully investigated via computational intelligence techniques. The best performance device according to our simulations presents a collimated e-beam profile that suits well for field emission displays, magnetic field detection and electron microscopy. The automated computational design tool presented in this study strongly benefits the robust design of integrated electron-optical systems for vacuum field emission applications, including electrodynamic tethering and electric propulsion systems.

  19. SU-F-BRD-10: Lung IMRT Planning Using Standardized Beam Bouquet Templates

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, L; Wu, Q J.; Yin, F [Duke University Medical Center, Durham, NC (United States); Ge, Y [University of North Carolina at Charlotte, Charlotte, NC (United States)

    2014-06-15

    Purpose: We investigate the feasibility of choosing from a small set of standardized templates of beam bouquets (i.e., entire beam configuration settings) for lung IMRT planning to improve planning efficiency and quality consistency, and also to facilitate automated planning. Methods: A set of beam bouquet templates is determined by learning from the beam angle settings in 60 clinical lung IMRT plans. A k-medoids cluster analysis method is used to classify the beam angle configuration into clusters. The value of the average silhouette width is used to determine the ideal number of clusters. The beam arrangements in each medoid of the resulting clusters are taken as the standardized beam bouquet for the cluster, with the corresponding case taken as the reference case. The resulting set of beam bouquet templates was used to re-plan 20 cases randomly selected from the database and the dosimetric quality of the plans was evaluated against the corresponding clinical plans by a paired t-test. The template for each test case was manually selected by a planner based on the match between the test and reference cases. Results: The dosimetric parameters (mean±S.D. in percentage of prescription dose) of the plans using 6 beam bouquet templates and those of the clinical plans, respectively, and the p-values (in parenthesis) are: lung Dmean: 18.8±7.0, 19.2±7.0 (0.28), esophagus Dmean: 32.0±16.3, 34.4±17.9 (0.01), heart Dmean: 19.2±16.5, 19.4±16.6 (0.74), spinal cord D2%: 47.7±18.8, 52.0±20.3 (0.01), PTV dose homogeneity (D2%-D99%): 17.1±15.4, 20.7±12.2 (0.03).The esophagus Dmean, cord D02 and PTV dose homogeneity are statistically better in the plans using the standardized templates, but the improvements (<5%) may not be clinically significant. The other dosimetric parameters are not statistically different. Conclusion: It's feasible to use a small number of standardized beam bouquet templates (e.g. 6) to generate plans with quality comparable to that of clinical

  20. SU-F-BRD-10: Lung IMRT Planning Using Standardized Beam Bouquet Templates

    International Nuclear Information System (INIS)

    Purpose: We investigate the feasibility of choosing from a small set of standardized templates of beam bouquets (i.e., entire beam configuration settings) for lung IMRT planning to improve planning efficiency and quality consistency, and also to facilitate automated planning. Methods: A set of beam bouquet templates is determined by learning from the beam angle settings in 60 clinical lung IMRT plans. A k-medoids cluster analysis method is used to classify the beam angle configuration into clusters. The value of the average silhouette width is used to determine the ideal number of clusters. The beam arrangements in each medoid of the resulting clusters are taken as the standardized beam bouquet for the cluster, with the corresponding case taken as the reference case. The resulting set of beam bouquet templates was used to re-plan 20 cases randomly selected from the database and the dosimetric quality of the plans was evaluated against the corresponding clinical plans by a paired t-test. The template for each test case was manually selected by a planner based on the match between the test and reference cases. Results: The dosimetric parameters (mean±S.D. in percentage of prescription dose) of the plans using 6 beam bouquet templates and those of the clinical plans, respectively, and the p-values (in parenthesis) are: lung Dmean: 18.8±7.0, 19.2±7.0 (0.28), esophagus Dmean: 32.0±16.3, 34.4±17.9 (0.01), heart Dmean: 19.2±16.5, 19.4±16.6 (0.74), spinal cord D2%: 47.7±18.8, 52.0±20.3 (0.01), PTV dose homogeneity (D2%-D99%): 17.1±15.4, 20.7±12.2 (0.03).The esophagus Dmean, cord D02 and PTV dose homogeneity are statistically better in the plans using the standardized templates, but the improvements (<5%) may not be clinically significant. The other dosimetric parameters are not statistically different. Conclusion: It's feasible to use a small number of standardized beam bouquet templates (e.g. 6) to generate plans with quality comparable to that of clinical

  1. Evaluation of beam delivery and ripple filter design for non-isocentric proton and carbon ion therapy

    Science.gov (United States)

    Grevillot, L.; Stock, M.; Vatnitsky, S.

    2015-10-01

    This study aims at selecting and evaluating a ripple filter design compatible with non-isocentric proton and carbon ion scanning beam treatment delivery for a compact nozzle. The use of non-isocentric treatments when the patient is shifted as close as possible towards the nozzle exit allows for a reduction in the air gap and thus an improvement in the quality of scanning proton beam treatment delivery. Reducing the air gap is less important for scanning carbon ions, but ripple filters are still necessary for scanning carbon ion beams to reduce the number of energy steps required to deliver homogeneous SOBP. The proper selection of ripple filters also allows a reduction in the possible transverse and depth-dose inhomogeneities that could appear in non-isocentric conditions in particular. A thorough review of existing ripple filter designs over the past 16 years is performed and a design for non-isocentric treatment delivery is presented. A unique ripple filter quality index (QIRiFi) independent of the particle type and energy and representative of the ratio between energy modulation and induced scattering is proposed. The Bragg peak width evaluated at the 80% dose level (BPW80) is proposed to relate the energy modulation of the delivered Bragg peaks and the energy layer step size allowing the production of homogeneous SOBP. Gate/Geant4 Monte Carlo simulations have been validated for carbon ion and ripple filter simulations based on measurements performed at CNAO and subsequently used for a detailed analysis of the proposed ripple filter design. A combination of two ripple filters in a series has been validated for non-isocentric delivery and did not show significant transverse and depth-dose inhomogeneities. Non-isocentric conditions allow a significant reduction in the spot size at the patient entrance (up to 350% and 200% for protons and carbon ions with range shifter, respectively), and therefore in the lateral penumbra in the patients.

  2. Evaluation of beam delivery and ripple filter design for non-isocentric proton and carbon ion therapy

    International Nuclear Information System (INIS)

    This study aims at selecting and evaluating a ripple filter design compatible with non-isocentric proton and carbon ion scanning beam treatment delivery for a compact nozzle. The use of non-isocentric treatments when the patient is shifted as close as possible towards the nozzle exit allows for a reduction in the air gap and thus an improvement in the quality of scanning proton beam treatment delivery. Reducing the air gap is less important for scanning carbon ions, but ripple filters are still necessary for scanning carbon ion beams to reduce the number of energy steps required to deliver homogeneous SOBP. The proper selection of ripple filters also allows a reduction in the possible transverse and depth-dose inhomogeneities that could appear in non-isocentric conditions in particular.A thorough review of existing ripple filter designs over the past 16 years is performed and a design for non-isocentric treatment delivery is presented. A unique ripple filter quality index (QIRiFi) independent of the particle type and energy and representative of the ratio between energy modulation and induced scattering is proposed. The Bragg peak width evaluated at the 80% dose level (BPW80) is proposed to relate the energy modulation of the delivered Bragg peaks and the energy layer step size allowing the production of homogeneous SOBP. Gate/Geant4 Monte Carlo simulations have been validated for carbon ion and ripple filter simulations based on measurements performed at CNAO and subsequently used for a detailed analysis of the proposed ripple filter design.A combination of two ripple filters in a series has been validated for non-isocentric delivery and did not show significant transverse and depth-dose inhomogeneities. Non-isocentric conditions allow a significant reduction in the spot size at the patient entrance (up to 350% and 200% for protons and carbon ions with range shifter, respectively), and therefore in the lateral penumbra in the patients. (paper)

  3. Commissioning of a compact laser-based proton beam line for high intensity bunches around 10Â MeV

    Science.gov (United States)

    Busold, S.; Schumacher, D.; Deppert, O.; Brabetz, C.; Kroll, F.; Blažević, A.; Bagnoud, V.; Roth, M.

    2014-03-01

    We report on the first results of experiments with a new laser-based proton beam line at the GSI accelerator facility in Darmstadt. It delivers high current bunches at proton energies around 9.6 MeV, containing more than 109 particles in less than 10 ns and with tunable energy spread down to 2.7% (ΔE/E0 at FWHM). A target normal sheath acceleration stage serves as a proton source and a pulsed solenoid provides for beam collimation and energy selection. Finally a synchronous radio frequency (rf) field is applied via a rf cavity for energy compression at a synchronous phase of -90 deg. The proton bunch is characterized at the end of the very compact beam line, only 3 m behind the laser matter interaction point, which defines the particle source.

  4. Carbon ion beam treatment in patients with primary and recurrent sacrococcygeal chordoma

    Energy Technology Data Exchange (ETDEWEB)

    Uhl, Matthias; Jensen, Alexandra; Herfarth, Klaus [University of Heidelberg, Department of Radiation Oncology, Heidelberg (Germany); Heidelberg Ion Beam Therapy Center (HIT), Heidelberg (Germany); Welzel, Thomas [University of Heidelberg, Department of Radiation Oncology, Heidelberg (Germany); Ellerbrock, Malte; Haberer, Thomas [Heidelberg Ion Beam Therapy Center (HIT), Heidelberg (Germany); Jaekel, Oliver [University of Heidelberg, Department of Radiation Oncology, Heidelberg (Germany); Heidelberg Ion Beam Therapy Center (HIT), Heidelberg (Germany); German Cancer Research Center (dkfz), Heidelberg (Germany); Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg (Germany); Debus, Juergen [University of Heidelberg, Department of Radiation Oncology, Heidelberg (Germany); Heidelberg Ion Beam Therapy Center (HIT), Heidelberg (Germany); German Cancer Research Center (dkfz), Heidelberg (Germany); Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg (Germany); Deutsches Konsortium fuer Translationale Krebsforschung (DKTK), Heidelberg (Germany)

    2015-07-15

    The purpose of this work was to evaluate the results of high-dose radiation treatment using carbon ion therapy, alone or combined with intensity-modulated radiation treatment (IMRT), in patients with sacral chordoma. Between 2009 and 2012, 56 patients with sacral chordoma were treated in our center. The tumor was located above S3 in 33 patients and in S3 or below in 23 patients. In all, 41 patients received radiation therapy for the primary tumor, while 15 patients were treated for the recurrent tumor. Toxicity was measured using NCI CTCAE v.4.03. Local control (LC) and overall survival (OS) were evaluated with the Kaplan-Meier method. A total of 23 patients were irradiated with carbon ions in combination with photon IMRT, while 33 received carbon ion therapy only. Forty-three patients had a macroscopic tumor at treatment start with a median tumor size (GTV) of 244 ml (range 5-1188 ml). The median total dose was 66 Gy (range 60-74 Gy; RBE). After a median follow-up time of 25 months, the 2- and 3-year local control probability was 76 % and 53 %, respectively. The overall survival rate was 100 %. Treatment for primary tumor and male patients resulted in significant better local control. No higher toxicity occurred within the follow-up time. High-dose photon/carbon ion beam radiation therapy is safe and, especially for primary sacral chordomas, highly effective. A randomized trial is required to evaluate the role of primary definitive hypofractionated particle therapy compared with surgery with or without adjuvant radiotherapy. (orig.) [German] Evaluierung der Ergebnisse nach hochdosierter Kohlenstoffionentherapie, allein oder in Kombination mit einer intensitaetsmodulierten Photonenbestrahlung (IMRT), bei Patienten mit einem sakralen Chordom. Zwischen 2009 und 2012 wurden 56 Patienten mit sakralen Chordomen in unserem Zentrum behandelt. Der Tumor war bei 33 Patienten oberhalb von S3 und bei 23 Patienten auf Hoehe von S3 oder unterhalb davon lokalisiert. Insgesamt

  5. Monte Carlo validation of the TrueBeam 10XFFF phase–space files for applications in lung SABR

    Energy Technology Data Exchange (ETDEWEB)

    Teke, Tony, E-mail: tteke2@bccancer.bc.ca [Medical Physics, BC Cancer Agency—Centre for the Southern Interior, Kelowna, British Columbia V1Y 5L3 (Canada); Duzenli, Cheryl; Bergman, Alanah; Viel, Francis; Atwal, Parmveer; Gete, Ermias [Medical Physics, BC Cancer Agency—Vancouver Centre, Vancouver, British Columbia V5Z 4E6 (Canada)

    2015-12-15

    Purpose: To establish the clinical acceptability of universal Monte Carlo phase–space data for the 10XFFF (flattening filter free) photon beam on the Varian TrueBeam Linac, including previously unreported data for small fields, output factors, and inhomogeneous media. The study was particularly aimed at confirming the suitability for use in simulations of lung stereotactic ablative radiotherapy treatment plans. Methods: Monte Carlo calculated percent depth doses (PDDs), transverse profiles, and output factors for the TrueBeam 10 MV FFF beam using generic phase–space data that have been released by the Varian MC research team were compared with in-house measurements and published data from multiple institutions (ten Linacs from eight different institutions). BEAMnrc was used to create field size specific phase–spaces located underneath the jaws. Doses were calculated with DOSXYZnrc in a water phantom for fields ranging from 1 × 1 to 40 × 40 cm{sup 2}. Particular attention was paid to small fields (down to 1 × 1 cm{sup 2}) and dose per pulse effects on dosimeter response for high dose rate 10XFFF beams. Ion chamber measurements were corrected for changes in ion collection efficiency (P{sub ion}) with increasing dose per pulse. MC and ECLIPSE ANISOTROPIC ANALYTICAL ALGORITHM (AAA) calculated PDDs were compared to Gafchromic film measurement in inhomogeneous media (water, bone, lung). Results: Measured data from all machines agreed with Monte Carlo simulations within 1.0% and 1.5% for PDDs and in-field transverse profiles, respectively, for field sizes >1 × 1 cm{sup 2} in a homogeneous water phantom. Agreements in the 80%–20% penumbra widths were better than 2 mm for all the fields that were compared. For all the field sizes considered, the agreement between their measured and calculated output factors was within 1.1%. Monte Carlo results for dose to water at water/bone, bone/lung, and lung/water interfaces as well as within lung agree with film

  6. Monte Carlo validation of the TrueBeam 10XFFF phase–space files for applications in lung SABR

    International Nuclear Information System (INIS)

    Purpose: To establish the clinical acceptability of universal Monte Carlo phase–space data for the 10XFFF (flattening filter free) photon beam on the Varian TrueBeam Linac, including previously unreported data for small fields, output factors, and inhomogeneous media. The study was particularly aimed at confirming the suitability for use in simulations of lung stereotactic ablative radiotherapy treatment plans. Methods: Monte Carlo calculated percent depth doses (PDDs), transverse profiles, and output factors for the TrueBeam 10 MV FFF beam using generic phase–space data that have been released by the Varian MC research team were compared with in-house measurements and published data from multiple institutions (ten Linacs from eight different institutions). BEAMnrc was used to create field size specific phase–spaces located underneath the jaws. Doses were calculated with DOSXYZnrc in a water phantom for fields ranging from 1 × 1 to 40 × 40 cm2. Particular attention was paid to small fields (down to 1 × 1 cm2) and dose per pulse effects on dosimeter response for high dose rate 10XFFF beams. Ion chamber measurements were corrected for changes in ion collection efficiency (Pion) with increasing dose per pulse. MC and ECLIPSE ANISOTROPIC ANALYTICAL ALGORITHM (AAA) calculated PDDs were compared to Gafchromic film measurement in inhomogeneous media (water, bone, lung). Results: Measured data from all machines agreed with Monte Carlo simulations within 1.0% and 1.5% for PDDs and in-field transverse profiles, respectively, for field sizes >1 × 1 cm2 in a homogeneous water phantom. Agreements in the 80%–20% penumbra widths were better than 2 mm for all the fields that were compared. For all the field sizes considered, the agreement between their measured and calculated output factors was within 1.1%. Monte Carlo results for dose to water at water/bone, bone/lung, and lung/water interfaces as well as within lung agree with film measurements to within 2.8% for 10

  7. Sub-10 nm beam confinement by X-ray waveguides: design, fabrication and characterization of optical properties

    International Nuclear Information System (INIS)

    Optimized X-ray waveguides have been fabricated and characterized in terms of transmission, angular acceptance, farfield pattern and imaging applications. Beam confinement down to sub-10 nm in two orthogonal directions has been demonstrated, at the nano-focus endstation at P10 of PETRA III at HASYLAB/DESY. The propagation of hard X-ray synchrotron beams in waveguides with guiding layer diameters in the 9–35 nm thickness range has been studied. The planar waveguide structures consist of an optimized two-component cladding. The presented fabrication method is suitable for short and leak-proof waveguide slices with lengths (along the optical axis) in the sub-500 µm range, adapted for optimized transmission at photon energies of 11.5–18 keV. A detailed comparison between finite-difference simulations of waveguide optics and the experimental results is presented, concerning transmission, divergence of the waveguide exit beam, as well as the angular acceptance. In a second step, two crossed waveguides have been used to create a quasi-point source for propagation-based X-ray imaging at the new nano-focus endstation of the P10 coherence beamline at Petra III. By inverting the measured Fraunhofer diffraction pattern by an iterative error-reduction algorithm, a two-dimensional focus of 10 nm × 10 nm is obtained. Finally, holographic imaging of a lithographic test structure based on this optical system is demonstrated

  8. Very high temperature chemical vapor deposition of new carbon thin films using organic semiconductor molecular beam sources

    Energy Technology Data Exchange (ETDEWEB)

    Noguchi, Takuya [Department of Chemistry, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033 (Japan); Shimada, Toshihiro, E-mail: shimada@chem.s.u-tokyo.ac.j [Department of Chemistry, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033 (Japan); Hanzawa, Akinori; Hasegawa, Tetsuya [Department of Chemistry, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033 (Japan)

    2009-11-30

    We carried out the preparation and characterization of new carbon films deposited using an organic molecular beam deposition apparatus with very high substrate temperature (from room temperature to 2670 K), which we newly developed. When we irradiated molecular beam of organic semiconductor perylene tetracarboxylic acid dianhydride (PTCDA) on Y{sub 0.07}Zr{sub 0.93}O{sub 2} (111) at 2170 K, a new carbon material was formed via decomposition and fusing of the molecules. The films were characterized with an atomic force microscope (AFM), Raman spectroscopy, X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). Zirconium carbide (ZrC) films were identified beneath the topmost carbon layer by XRD and XPS analyses, which results from chemical reactions of the substrate and the molecules. Partially graphitized aromatic rings of PTCDA were observed from Raman spectroscopy. The present technique - very high temperature chemical vapor deposition using organic semiconductor sources - will be useful to study a vast unexplored field of covalent carbon solids.

  9. MODIFICATION OF CARBON STEEL BY LASER SURFACE MELTING: PART I: EFFECT OF LASER BEAM TRAVELLING SPEED ON MICROSTRUCTURAL FEATURES AND SURFACE HARDNESS

    OpenAIRE

    Hashem F. El-Labban; Abdelaziz, M.; Essam R.I. Mahmoud

    2013-01-01

    The present study aims to improve the surface hardness of carbon steel by application of laser surface melting of effective conditions. The travelling speed of laser beam during this treatment is one of the important treatment conditions. This study aims to investigate the effect of laser surface melting with different beam speeds on macro and microstructure as well as the hardness distribution through the thickness of carbon steel. To achieve this target, three different travelling speeds (1...

  10. Effects of porous carbon additives and induced fluorine on low dielectric constant polyimide synthesized with an e-beam

    International Nuclear Information System (INIS)

    We report the synthesis of a polyimide matrix with a low dielectric constant for application as an intercalation material between metal interconnections in electronic devices. Porous activated carbon was embedded in the polyimide to reduce the dielectric constant, and a thin film of the complex was obtained using the spin-coating and e-beam irradiation methods. The surface of the thin film was modified with fluorine functional groups to impart water resistance and reduce the dielectric constant further. The water resistance was significantly improved by the modification with hydrophobic fluorine groups. The dielectric constant was effectively decreased by porous activated carbon. The fluorine modification also resulted in a low dielectric constant on the polyimide surface by reducing the polar surface free energy. The dielectric constant of polyimide film decreased from 2.98 to 1.9 by effects of porous activated carbon additive and fluorine surface modification.

  11. Carbon-10: Example of cyclotron production of positron emitters as an open research field

    DEFF Research Database (Denmark)

    Alves, F.; Lima, J.J.P.; Nickles, R.J.;

    2007-01-01

    This paper supports the thesis that significant improvement of PET output response to clinical questions can be achieved by innovation in radionuclide production. Moreover, that development can be performed with the resources available at a clinical centre. Carbon-10 production parameters studies...

  12. Resonant Enhancement of Coherent Phonons in Carbon Nanotubes Observed with Sub-10fs Time Resolution

    Directory of Open Access Journals (Sweden)

    Yanagi K.

    2013-03-01

    Full Text Available Using wavelength-resolved pump-probe spectroscopy with a sub-10-fs laser, we investigated resonant enhancement of radial breathing mode and G-mode coherent phonons in carbon nanotubes (CNTs, and successfully distinguished the electronic states of CNTs with different chiralities.

  13. Performance of three pencil-type ionization chambers (10 cm) in computed tomography standard beams

    Science.gov (United States)

    de Castro, Maysa C.; Xavier, Marcos; Caldas, Linda V. E.

    2016-07-01

    The use of computed tomography (CT) has increased over the years, thus generating a concern about the doses received by patients undergoing this procedure. Therefore, it is necessary to perform routinely beam dosimetry with the use of a pencil-type ionization chamber. This detector is the most utilized in the procedures of quality control tests on this kind of equipment. The objective of this work was to perform some characterization tests in standard CT beams, as the saturation curve, polarity effect, ion collection efficiency and linearity of response, using three ionization chambers, one commercial and two developed at the IPEN.

  14. Study the structure of neutron deficient carbon isotopes: 10C and 11C. Elastic and inelastic scattering on proton target

    International Nuclear Information System (INIS)

    This work is devoted to the study of the structure of neutron-deficient carbon isotopes: 10C and 11C. A theoretical model predicts a special behaviour for these nuclei: different deformations for neutron and proton densities. To test these predictions and to obtain information on the structure of these nuclei, we measured angular distribution for elastic and inelastic scattering on proton target with inverse kinematics at 40 MeV per nucleon. The angular distribution is deduced from the proton energy and angle scattering, measured by the MUST detector. Experimental set-up is completed with plastic detectors for scattered nucleus identification and with two CATS detectors for measurement of position and angle for each beam particle on the target. Angular distributions are calculated with an analytic method. This method is tested with a simulation and with 12C + p scattering analysis. Angular distributions are analysed in terms of a complex microscopic potential JLM with different microscopic matter densities. Elastic scattering gives an information on 10C and 11C matter root mean square radii. Both radii are larger than the one for the stable 12C isotope. Inelastic scattering is treated in DWBA approximation with microscopic transition densities. 10C inelastic scattering gives an information on neutron contribution of nucleus excitation. With 11C inelastic scattering, we could constrain transition densities and we could extract an information on the type of the transition. However, it is very difficult to confirm or to annul predictions of different deformations for proton and neutrons densities. (author)

  15. Friction and Wear of Ion-Beam-Deposited Diamondlike Carbon on Chemical-Vapor-Deposited, Fine-Grain Diamond

    Science.gov (United States)

    Miyoshi, Kazuhisa; Wu, Richard L. C.; Lanter, William C.

    1996-01-01

    Friction and wear behavior of ion-beam-deposited diamondlike carbon (DLC) films coated on chemical-vapor-deposited (CVD), fine-grain diamond coatings were examined in ultrahigh vacuum, dry nitrogen, and humid air environments. The DLC films were produced by the direct impact of an ion beam (composed of a 3:17 mixture of Ar and CH4) at ion energies of 1500 and 700 eV and an RF power of 99 W. Sliding friction experiments were conducted with hemispherical CVD diamond pins sliding on four different carbon-base coating systems: DLC films on CVD diamond; DLC films on silicon; as-deposited, fine-grain CVD diamond; and carbon-ion-implanted, fine-grain CVD diamond on silicon. Results indicate that in ultrahigh vacuum the ion-beam-deposited DLC films on fine-grain CVD diamond (similar to the ion-implanted CVD diamond) greatly decrease both the friction and wear of fine-grain CVD diamond films and provide solid lubrication. In dry nitrogen and in humid air, ion-beam-deposited DLC films on fine-grain CVD diamond films also had a low steady-state coefficient of friction and a low wear rate. These tribological performance benefits, coupled with a wider range of coating thicknesses, led to longer endurance life and improved wear resistance for the DLC deposited on fine-grain CVD diamond in comparison to the ion-implanted diamond films. Thus, DLC deposited on fine-grain CVD diamond films can be an effective wear-resistant, lubricating coating regardless of environment.

  16. Facility to disinfect medical wastes by 10 MeV electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Kerluke, D.R. [Ion Beam Applications s.a., Louvain-la-Neuve (Belgium)

    1998-12-31

    As regulations related to the disposal of infectious hospital and other medical waste are become increasingly stringent, hospitals and governments worldwide are looking to develop more effective and economical means to disinfect such waste materials prior to them being ultimately landfilled, incinerated or recycled. With the advent of reliable high-energy, high-power industrial electron accelerators, the prospect now exists to centralize collection of much of the infectious medical waste for major metropolitan areas at a single facility, and render it harmless using irradiation. Using much of the same or similar methodologies already developed for single-use medical device sterilization and for bioburden reduction in other goods, high energy electron beam treatment offers unique process advantages which become increasingly attractive with the economies of scale available at higher power. This paper will explore some of the key issues related to the safe disposition of infectious hospital and other medical waste, related irradiation research projects, and the design and economic factors related to an electron beam facility dedicated to this application. This will be presented in the context of the Rhodotron family of electron beam accelerators manufactured by Ion Beam Applications s.a. (author)

  17. Scanned carbon beam irradiation of moving films: comparison of measured and calculated response

    International Nuclear Information System (INIS)

    Treatment of moving target volumes with scanned particle beams benefits from treatment planning that includes the time domain (4D). Part of 4D treatment planning is calculation of the expected result. These calculation codes should be verified against suitable measurements. We performed simulations and measurements to validate calculation of the film response in the presence of target motion. All calculations were performed with GSI's treatment planning system TRiP. Interplay patterns between scanned particle beams and moving film detectors are very sensitive to slight deviations of the assumed motion parameters and therefore ideally suited to validate 4D calculations. In total, 14 film motion parameter combinations with lateral motion amplitudes of 8, 15, and 20 mm and 4 combinations for lateral motion including range changes were used. Experimental and calculated film responses were compared by relative difference, mean deviation in two regions-of-interest, as well as line profiles. Irradiations of stationary films resulted in a mean relative difference of -1.52% ± 2.06% of measured and calculated responses. In comparison to this reference result, measurements with translational film motion resulted in a mean difference of -0.92% ± 1.30%. In case of irradiations incorporating range changes with a stack of 5 films as detector the deviations increased to -6.4 ± 2.6% (-10.3 ± 9.0% if film in distal fall-off is included) in comparison to -3.6% ± 2.5% (-13.5% ± 19.9% including the distal film) for the stationary irradiation. Furthermore, the comparison of line profiles of 4D calculations and experimental data showed only slight deviations at the borders of the irradiated area. The comparisons of pure lateral motion were used to determine the number of motion states that are required for 4D calculations depending on the motion amplitude. 6 motion states per 10 mm motion amplitude are sufficient to calculate the film response in the presence of motion. By

  18. Fresnel absorption of 1 μm- and 10 μm-laser beams at the keyhole wall during laser beam welding: Comparison between smooth and wavy surfaces

    International Nuclear Information System (INIS)

    The angle-dependent absorption of laser beams at metal surfaces is described by the Fresnel-equations. During keyhole laser welding the essential interaction takes place at very striping angles of incidence of the order of 1-8 degrees at the front of the vapour capillary, called the keyhole. For a smooth vapour capillary, laser beams with a wavelength of about 1 μm operate in a Fresnel-regime where the absorptance increases with the angle of incidence at the wall, towards the weak Brewster-angle maximum. In contrast, for 10 μm-lasers high absorptance around the more pronounced Brewster-angle peak takes place. From high speed imaging keyhole surface waves were observed. Mathematical modelling of the laser-keyhole interaction demonstrates that already relatively little waviness of the melt surface at the keyhole strongly modulates the angles of incidence and in turn the Fresnel-absorption due to varying angles of incidence, soon also leading to shadow zones. Due to this local variation of the angle of incidence the absorptance tends towards the angle-averaged value, with the consequence that for 1 μm-lasers the direct absorptance and in turn the penetration depth increases, particularly at low welding speed, while for 10 μm-lasers it generally decreases.

  19. Experimental study of the water-to-air stopping power ratio of monoenergetic carbon ion beams for particle therapy

    Science.gov (United States)

    Sánchez-Parcerisa, D.; Gemmel, A.; Jäkel, O.; Parodi, K.; Rietzel, E.

    2012-06-01

    Reference dosimetry with ionization chambers requires a number of chamber-specific and beam-specific calibration factors. For carbon ion beams, IAEA report TRS-398 yields a total uncertainty of 3% in the determination of the absorbed dose to water, for which the biggest contribution arises from the water-to-air stopping power ratio (sw, air), with an uncertainty of 2%. The variation of (sw, air) along the treatment field has been studied in several Monte Carlo works presented over the last few years. Their results were, in all cases, strongly dependent on the choice of mean ionization potentials (I-values) for air and water. A smaller dependence of (sw, air) with penetration depth was observed. Since a consensus on Iw, air and Iair has not yet been reached, the validity of such studies for clinical use cannot be assessed independently. Our approach is based on a direct experimental measurement of water-equivalent thicknesses of different air gaps at different beam energies. A theoretical expression describing the variation of the stopping power ratio with kinetic energy, sw,air(E), was derived from the Bethe-Bloch formula and fit to the measured data, yielding a coherent pair of Iw and Iair values with Iair/Iw = 1.157 ± 0.023. Additionally, the data from five different beam energies were combined in an average value of sw,air = 1.132 ± 0.003 (statistical) ± 0.003 (variation over energy range), valid for monoenergetic carbon ion beams at the plateau area of the depth dose distribution. A detailed uncertainty analysis was performed on the data, in order to assess the limitations of the method, yielding an overall standard uncertainty below 1% in sw,air(E). Therefore, when properly combined with the appropriate models for the fragment spectra, our experimental work can contribute to narrow the uncertainty margins currently in use in absorbed dose to water determination for dosimetry of carbon ion beam radiotherapy.

  20. Extended high order sandwich panel theory for bending analysis of sandwich beams with carbon nanotube reinforced face sheets

    Science.gov (United States)

    Jedari Salami, S.

    2016-02-01

    Bending analysis of a sandwich beam with soft core and carbon nanotube reinforced composite (CNTRC) face sheets in the literature is presented based on Extended High order Sandwich Panel Theory (EHSAPT). Distribution of fibers through the thickness of the face sheets could be uniform or functionally graded (FG). In this theory the face sheets follow the first order shear deformation theory (FSDT). Besides, the two dimensional elasticity is used for the core. The field equations are derived via the Ritz based solution which is suitable for any essential boundary condition. The influences of boundary conditions on bending response of the sandwich panel with soft core and CNTRC face sheet are investigated. In each type of boundary condition the effect of distribution pattern of CNTRCs on many essential involved parameters of the sandwich beam with functionally graded carbon nanotube reinforced composite (FG- CNTRC) face sheets are studied in detail. Finally, experimental result have been compared with those obtained based on developed solution method. It is concluded that, the sandwich beam with X distribution figure of face sheets is the strongest with the smallest transverse displacement, and followed by the UD, O and ∧-ones, respectively.

  1. Carbon-10: Example of cyclotron production of positron emitters as an open research field

    International Nuclear Information System (INIS)

    This paper supports the thesis that significant improvement of PET output response to clinical questions can be achieved by innovation in radionuclide production. Moreover, that development can be performed with the resources available at a clinical centre. Carbon-10 production parameters studies are used as example. A technical methodology for measurement of excitation function of nuclear reactions yielding short-lived radionuclides, performed to measure cross section values of the 10B(p,n)10C reaction in a PET-devoted cyclotron, is presented

  2. Beam optics of a 10-cm diameter high current heavy ion diode

    International Nuclear Information System (INIS)

    Typically a large diameter surface ionization source is used to produce > 0.5 A K+ current with emittance < 1 π-mm-mrad for heavy ion fusion experiments. So far we have observed aberrations that are slightly different from those predicted by computer simulations. We have now set up an experiment to study in detail the beam optics of such a large diameter ion diode and to benchmark the simulation code

  3. Proton, Helium and Carbon Radiation Beam Targeting Reactive Oxygen, Nitrogen and Halogenated Species in TRIM-SRIM Model

    International Nuclear Information System (INIS)

    Nowadays proton beam radiation therapy is considered in few centers for management of malignancies. This study is aimed to explore the effect of proton, helium or carbon irradiation on free radicals. This study was conducted in department of Physiology/Medical physics, College of Medicine, Al-Mustansiriya University in Baghdad, Iraq during October 2009. TRIM-SRIM software version 1998 and2003 were used for computed Bragg peak and for calculated the effect of proton, helium and carbon ions against free radicals related to oxygen, nitrogen and halogen species. The lowest stopping power near Bragg's peak of proton targeting free radicals was against superoxide anion and its curve (the stopping power against energy) was shifted down while that of peroxynitrite(ONOO-) was shifted up. The stopping powers of helium targeting all studied free radicals were lower than corresponding proton irradiation but it required higher energy. Lower stopping power of carbon irradiation targeted hydroxyl(OH-) and halogenated radicals than the other reactive species were observed. It concludes that such from of external beam irradiation is associated with direct scavenging effect on free radicals of whatever sources.

  4. Study on reinforced concrete beams strengthened using shape memory alloy wires in combination with carbon-fiber-reinforced polymer plates

    Science.gov (United States)

    Li, Hui; Liu, Zhi-qiang; Ou, Jin-ping

    2007-12-01

    It has been proven that carbon-fiber-reinforced polymer (CFRP) sheets or plates are capable of improving the strength of reinforced concrete (RC) structures. However, residual deformation of RC structures in service reduces the effect of CFRP strengthening. SMA can be applied to potentially decrease residual deformation and even close concrete cracks because of its recovery forces imposed on the concrete when heated. Therefore, a method of a RC structure strengthened by CFRP plates in combination with SMA wires is proposed in this paper. The strengthening effect of this method is investigated through experiments and numerical study based on the nonlinear finite element software ABAQUS in simple RC beams. Parametric analysis and assessment of damage by defining a damage index are carried out. The results indicate that recovery forces of SMA wires can decrease deflections and even close cracks in the concrete. The recovery rate of deflection of the beam increases with increasing the ratio of SMA wires. The specimen strengthened with CFRP plates has a relatively large stiffness and smaller damage index value when the residual deformation of the beam is first reduced by activation of the SMA wires. The effectiveness of this strengthening method for RC beams is verified by experimental and numerical results.

  5. Lactose and sucrose aqueous solutions for high-dose dosimetry with 10-MeV electron beam irradiation

    International Nuclear Information System (INIS)

    In the present study, dosimetric characterisation of aqueous solutions of lactose and sucrose was analysed by UV spectrometry following irradiation using 10-MeV electron beam at doses between 0.5 and 10.5 kGy. As a dosimetric index, absorbance is selected at 256 and 264 nm for lactose and sucrose aqueous solutions, respectively. The intensity of absorbance for irradiated solutions depends on the pre-irradiation concentration of lactose and sucrose. The post-irradiation stability of both solutions was investigated at room temperature for a measurement period of 22 d. (authors)

  6. Generation of intense pulsed ion beam by a Br type magnetically insulated ion diode with carbon plasma gun

    International Nuclear Information System (INIS)

    To apply the pulsed heavy ion beam (PHIB) to an implantation process of semiconductor, purity of the ion beam is very important. To obtain a pure PHIB we have proposed a new type of accelerator using bipolar pulse. To develop the accelerator we are developing a new type of Br ion diode using a carbon plasma gun. By using the plasma gun, ion source plasma of ion current density approx. = 30 A/cm2 was obtained. The Br ion diode was successfully operated with plasma gun at diode voltage approx. = 100 kV, diode current approx. = 1 kA, pulse duration approx. = 200 ns and 3 A/cm2 of ion current density was obtained. (author)

  7. Formation of nanoscale carbon structures in the surface layer of metals under the impact of high intensity ion beam

    Energy Technology Data Exchange (ETDEWEB)

    Remnev, G.E., E-mail: remnev@hvd.tpu.ru [High-Voltage Research Institute at Tomsk Polytechnic University, 2a Lenin Ave., Tomsk 634028 (Russian Federation); Uglov, V.V., E-mail: uglov@bsu.by [Belarusian State University, 4 Nezavisimosti Ave., Minsk 220030 (Belarus); Shymanski, V.I. [Belarusian State University, 4 Nezavisimosti Ave., Minsk 220030 (Belarus); Pavlov, S.K. [High-Voltage Research Institute at Tomsk Polytechnic University, 2a Lenin Ave., Tomsk 634028 (Russian Federation); Kuleshov, A.K. [Belarusian State University, 4 Nezavisimosti Ave., Minsk 220030 (Belarus)

    2014-08-15

    Highlights: • Carbide phases in metals were formed by high-intense pulsed ion beam (HPIB) impact. • Tungsten and titanium carbides are characterized by nanoscale dimensions. • Carbides formation in surface layer provides its hardening. - Abstract: This work represents the results of phase composition and the mechanical properties of tungsten and titanium after high-intensity pulsed ion beam (HPIB) treatment. It was shown that nanoscale carbide particles are formed under the HPIB influence in the surface layers of metals. Raising the pulse number results in increase of volume fraction of the carbide phases. The microhardness is 1.5–2 times more than the initial value and wear resistance of the metals improves in response to alloying of tungsten and titanium with carbon atoms accompanied by the formation of carbides.

  8. Measurement of the analyzing power for proton-carbon elastic scattering in the CNI region with a 22 GeV/c polarized proton beam

    International Nuclear Information System (INIS)

    We have carried out the experiment BNL-AGS E950 to measure the analyzing power for proton-carbon elastic scattering in the Coulomb-Nuclear Interference (CNI) region with a 22 GeV/c polarized proton beam. Recoil carbons from 300 keV to a few MeV in the CNI region, were detected inside the AGS ring to identify proton-carbon elastic scattering. The preliminary results of the analyzing power measurement are presented

  9. Effects of E-Beam Irradiation on the Chemical, Physical, and Electrochemical Properties of Activated Carbons for Electric Double-Layer Capacitors

    OpenAIRE

    Min-Jung Jung; Mi-Seon Park; Young-Seak Lee

    2015-01-01

    Activated carbons (ACs) were modified via e-beam irradiation at various doses for use as an electrode material in electric double-layer capacitors (EDLCs). The chemical compositions of the AC surfaces were largely unchanged by the e-beam irradiation. The ACs treated with the e-beam at radiation doses of 200 kGy exhibited higher nanocrystallinity than the untreated ACs. The specific surface areas and pore volumes of the e-beam irradiated ACs were also higher than those of the untreated ACs. Th...

  10. Generation of oxygen, carbon and metallic ion beams by a compact microwave source

    International Nuclear Information System (INIS)

    A small microwave ion source fabricated from a quartz tube and enclosed externally by a cavity has been operated with different geometries and for various gases in a cw mode. This source has been used to generate oxygen ion beams with energy as low as 5.5 eV. Beam energy spread has been measured to be less than 1 eV. By installing different metal plates on the front extraction electrode, metallic ion beams such as (Be, Cu, Al, etc.) can be produced

  11. Carbon fiber composite targets for nuclear fusion technology: a focused ion beam/scanning electron microscope investigation.

    Science.gov (United States)

    Ghezzi, F; Magni, S; Milani, M; Tatti, F

    2007-01-01

    Carbon fiber composite (CFC) targets are investigated by a focused ion beam/scanning electron microscope (FIB/SEM) in a joint project aiming at the development of robust divertors in the International Thermonuclear Experimental Reactor (ITER). These mockups are exposed to a plasma that simulates the off-normal thermal loads foreseen for ITER and display a rich, puzzling impact scenario. Morphological elements are identified at the exposed surface and beneath it, and are examined in order to point out the relevant processes involved. Each technique adopted is discussed and evaluated. PMID:18200678

  12. Low-dose (10-Gy) total skin electron beam therapy for cutaneous T-cell lymphoma

    DEFF Research Database (Denmark)

    Kamstrup, Maria R; zbr735, zbr735; Iversen, Lars;

    2015-01-01

    PURPOSE: Cutaneous T-cell lymphomas (CTCLs) are dominated by mycosis fungoides (MF) and Sézary syndrome (SS), and durable disease control is a therapeutic challenge. Standard total skin electron beam therapy (TSEBT) is an effective skin-directed therapy, but the possibility of retreatments is...... response or a very good partial response rate (<1% skin involvement with patches or plaques) documented in 57% of the patients. Median duration of overall cutaneous response was 174 days (5.8 months; range: 60-675 days). TSEBT-related acute adverse events (grade 1 or 2) were observed in 60% of patients...

  13. Vacuum Electron-Beam Evaporation of Fe Nanocrystals on Si3N4 Buffer Layer for carbon Nanotube Growth

    Institute of Scientific and Technical Information of China (English)

    万青; 王太宏; 林成鲁

    2003-01-01

    Vacuum electron-beam evaporated iron nanocrystal is used for the growth of carbon nanotubes. Atomic force microscopy and Raman scattering studies reveal the formation of beta-iron silicide islands on bare silicon substrate after annealing at 700°C in N2 ambient. In order to eliminate the influence of iron-silicon interaction, Si3N4 buffer layer with the thickness of 80 nm is used. This technical route prevents effectively the formation of iron silicide and improves the quality of the iron nanocrystals. Using these iron nanocrystals with high density (about 7 × 1010/cm2) as catalyst, high-density multiwall carbon nanotubes are synthesized on Si3N4/Si substrate.

  14. Synthesis of carbon-supported PtRh random alloy nanoparticles using electron beam irradiation reduction method

    Science.gov (United States)

    Matsuura, Yoshiyuki; Seino, Satoshi; Okazaki, Tomohisa; Akita, Tomoki; Nakagawa, Takashi; Yamamoto, Takao A.

    2016-05-01

    Bimetallic nanoparticle catalysts of PtRh supported on carbon were synthesized using an electron beam irradiation reduction method. The PtRh nanoparticle catalysts were composed of particles 2-3 nm in size, which were well dispersed on the surface of the carbon support nanoparticles. Analyses of X-ray diffraction and scanning transmission electron microscopy-energy-dispersive X-ray spectroscopy revealed that the PtRh nanoparticles have a randomly alloyed structure. The lattice constant of the PtRh nanoparticles showed good correlation with Vegard's law. These results are explained by the radiochemical formation process of the PtRh nanoparticles. Catalytic activities of PtRh/C nanoparticles for ethanol oxidation reaction were found to be higher than those obtained with Pt/C.

  15. Effect of properties of carbon fiber surface modified by anodic treatment and a coupling agent on electron beam cured epoxy composites

    International Nuclear Information System (INIS)

    A double modification method of carbon fiber surface physical and chemical properties was presented by which the carbon fibers were electrochemically oxidized and subsequently coated with an electron beam compatible coupling agent. The treated and untreated carbon fiber surface chemical properties and morphology were analyzed using atomic force microscopy (AFM) and x-ray photoelectron spectroscopy (XPS). And the carbon fiber surface energy was calculated through Kaelble method using contract angle measurement. The results show that the roughness and reactive groups of carbon fiber surface increase after anodic oxidization, moreover, polar composition of surface energy increase obviously. During EB curing the nitrogen-containing groups and basic species chemisorbed by carbon fiber surface restrain the initiators in the interface of composites, resulting in the weaker adhesion between the carbon fiber and the matrix. The coupling agent, acting as chemical bridge between the carbon fibers and the matrix, improves the interfacial properties of EB cured composites

  16. Proceedings of the 1986 summer workshop on antiproton beams in the 2-10 GeV/c range

    Energy Technology Data Exchange (ETDEWEB)

    Lazarus, D. (ed.)

    1987-05-07

    The possibilities for building a facility for the formation spectroscopy of ''charmonium'' and the study of ''exotics'' at the AGS with high intensity antiproton beams of good resolution and enhanced purity are explored. The performance potential of a number of long beams and the AGS booster are evaluated and costs are estimated. Fluxes of several 10/sup 7/ antiprotons per pulse with purities of 5% to 99% are possible with conventional long beams. A similar total antiproton flux would be available with the Booster with no beam contamination. This could effectively be enhanced by two orders of magnitude by reducing the momentum spread in order to scan very narrow (less than 1 MeV) resonances. The maximum momentum attainable with the present Booster magnet design is 5.6 GeV/c which only reaches the Chi/sub 0/ (3415) charmonium state. Modifications are possible which would raise the maximum momentum to 6.3 GeV/c to include all states up to and including eta'/sub c/ (3590) in its range. The performance potential for this physics at the AGS is found to compare favorably with that at other laboratories with more antiprotons delivered annually, running in the post-Booster era, than at FNAL or Super-Lear with ACOL under typical scheduling conditions. A high resolution purified source of antiprotons in the 2-10 GeV/c range at BNL would cost $3.0M - $4.1M including an experimental hall. There are contributed papers in the appendices.

  17. Monte Carlo simulations of the relative biological effectiveness for DNA double strand breaks from 300 MeV u−1 carbon-ion beams

    International Nuclear Information System (INIS)

    Monte Carlo simulations are used to calculate the relative biological effectiveness (RBE) of 300 MeV u−1 carbon-ion beams at different depths in a cylindrical water phantom of 10 cm radius and 30 cm long. RBE values for the induction of DNA double strand breaks (DSB), a biological endpoint closely related to cell inactivation, are estimated for monoenergetic and energy-modulated carbon ion beams. Individual contributions to the RBE from primary ions and secondary nuclear fragments are simulated separately. These simulations are based on a multi-scale modelling approach by first applying the FLUKA (version 2011.2.17) transport code to estimate the absorbed doses and fluence energy spectra, then using the MCDS (version 3.10A) damage code for DSB yields. The approach is efficient since it separates the non-stochastic dosimetry problem from the stochastic DNA damage problem. The MCDS code predicts the major trends of the DSB yields from detailed track structure simulations. It is found that, as depth is increasing, RBE values increase slowly from the entrance depth to the plateau region and change substantially in the Bragg peak region. RBE values reach their maxima at the distal edge of the Bragg peak. Beyond this edge, contributions to RBE are entirely from nuclear fragments. Maximum RBE values at the distal edges of the Bragg peak and the spread-out Bragg peak are, respectively, 3.0 and 2.8. The present approach has the flexibility to weight RBE contributions from different DSB classes, i.e. DSB0, DSB+ and DSB++. (paper)

  18. Measurement of small ion beams by thermal ionisation mass spectrometry using new 10¹³ Ohm resistors

    Energy Technology Data Exchange (ETDEWEB)

    Koornneef, J.M., E-mail: j.m.koornneef@vu.nl [Faculty of Earth and Life Sciences, Vrije Universiteit Amsterdam, de Boelelaan 1085, 1081HV Amsterdam (Netherlands); Bouman, C.; Schwieters, J.B. [Thermo Fisher Scientific, Hanna-Kunath-Str. 11, Bremen, 28199 (Germany); Davies, G.R. [Faculty of Earth and Life Sciences, Vrije Universiteit Amsterdam, de Boelelaan 1085, 1081HV Amsterdam (Netherlands)

    2014-03-01

    Highlights: • First data are presented using 10¹³ Ohm resistors connected to Faraday collectors. • 5 prototype 10¹³ Ohm resistors were installed in a TRITON-Plus TIMS. • Performance was tested by measuring Sr and Nd isotope ratios on <100 pg samples. • 10¹³ Ohm resistors perform better than ion counting and 10¹¹ Ohm resistors. • Fourth decimal variability can be resolved for Nd isotope ratios on 10 pg samples. Abstract: We tested 5 newly manufactured – prototype – 10¹³ Ohm resistors in the feedback loop of Faraday cup amplifiers to measure small ion beams by Thermal Ionisation Mass Spectrometry (TIMS). The high Ohmic resistors installed in the TRITON Plus at the VU University Amsterdam theoretically have 10 times lower noise levels relative to the default 10¹¹ Ohm resistors. To investigate the precision and accuracy of analyses using these new amplifiers we measured Sr and Nd isotopes of reference standards at a range of ion currents (3.2 × 10⁻¹⁶ to 1 × 10⁻¹² A, corresponding to intensities of 32 μV to 100 mV on a default 10¹¹ Ohm amplifier) and on small amounts of material (100 and 10 pg). Internal precision and external reproducibility for Sr and Nd isotope ratios are both better when collected on 10¹³ compared 10¹² Ohm resistors and to the default 10¹¹ Ohm resistors. At an ⁸⁷Sr ion current of 3 × 10⁻¹⁴ A (3 mV on a 10¹¹ Ohm amplifier) the internal precision (2 SE) of ⁸⁷Sr/⁸⁶Sr is 5 times better for 10¹³ Ohm resistors compared to 10¹¹ Ohm resistors. The external reproducibility (2 SD) at this beam intensity is 9 times better. Multiple 100 and 10 pg Sr standards, ran to exhaustion, yielded low ⁸⁷Sr/⁸⁶Sr compared to the long term average (e.g. 10 pg average = 0.710083 ± 164 (n = 11) instead of 0.710244 ± 12, n = 73). The average off-set for 10 pg standards can be explained by a loading blank contribution of 1.3 pg. In contrast, Nd data on 100 pg and 10 pg samples are accurate suggesting

  19. Study on suppression mechanism of electron emission from Mo grid coated with carbon film by dual ion beam deposition

    International Nuclear Information System (INIS)

    It is problematic that electrons are emitted from the Mo grid of pulsed-controlled grid traveling wave tubes, caused by the contamination of cathode evaporation material, i.e. BaO. Some studies show that a Mo grid coated with carbon can greatly suppress grid electron emission. However, the reason for the electron emission suppression is not completely clear. To understand the mechanism of electron emission suppression of a BaO/C/Mo system, carbon films were prepared on Mo substrates at room temperature by means of DIBSD (dual ion beam sputtering deposition), and BaO layers were coated by using a chemical method. Post-annealing was conducted under a flowing nitrogen ambient at 700 .deg. C for 1.5 hours. The structure of the as-deposited carbon films was evaluated by TEM, AES and Raman spectroscopy. The annealed samples, the BaO/ Mo and BaO/C/Mo systems, were analyzed by XPS. The results suggest that the chemical reaction between BaO and C at high temperature eliminates the concentrations of Ba or BaO on the surface of the C/Mo system. It can be believed that the high work function material used as the grid surface coating and elimination of BaO on its surface have a critical effect on grid electron emission suppression. Moreover, the carbon film was characterized by density, homogeneity and high adhesion, owing to the features of DIBSD.

  20. A TPS kernel for calculating survival vs. depth: distributions in a carbon radiotherapy beam, based on Katz's cellular track structure theory

    International Nuclear Information System (INIS)

    An algorithm was developed of a treatment planning system (TPS) kernel for carbon radiotherapy in which Katz's Track Structure Theory of cellular survival (TST) is applied as its radiobiology component. The physical beam model is based on available tabularised data, prepared by Monte Carlo simulations of a set of pristine carbon beams of different input energies. An optimisation tool developed for this purpose is used to find the composition of pristine carbon beams of input energies and fluences which delivers a pre-selected depth-dose distribution profile over the spread-out Bragg peak (SOBP) region. Using an extrapolation algorithm, energy-fluence spectra of the primary carbon ions and of all their secondary fragments are obtained over regular steps of beam depths. To obtain survival vs. depth distributions, the TST calculation is applied to the energy-fluence spectra of the mixed field of primary ions and of their secondary products at the given beam depths. Katz's TST offers a unique analytical and quantitative prediction of cell survival in such mixed ion fields. By optimising the pristine beam composition to a published depth-dose profile over the SOBP region of a carbon beam and using TST model parameters representing the survival of CHO (Chinese Hamster Ovary) cells in vitro, it was possible to satisfactorily reproduce a published data set of CHO cell survival vs. depth measurements after carbon ion irradiation. The authors also show by a TST calculation that 'biological dose' is neither linear nor additive. (authors)

  1. Electron spin resonance investigations on ion beam irradiated single-wall carbon nanotubes

    International Nuclear Information System (INIS)

    ESR investigations on single-wall carbon nanotubes irradiated with accelerated protons, helium ions, and neon ions are reported. All spectra were accurately simulated assuming that the resonance line is a convolution of up to 4 lines originating from catalyst residues, amorphous carbon, and electrons delocalized over the conducting domains of nanotubes. The faint line observed in irradiated nanotubes at g > 2.25 was assigned to magnetic impurities. However, there are no sufficient data to confirm that this line is connected to radiation-induced magnetism in carbon nanotubes. The generation of paramagnetic defects due to the bombardment of single-wall carbon nanotubes by accelerated ions is reported. These data correlate with previous Raman and thermal investigations on the same single-wall carbon nanotubes and reveals their sensitivity to ionizing radiation. The temperature dependence of ESR spectra in the range 25-250 K was used to identify the components of the ESR spectra

  2. 10 Orders of Magnitude Current Measurement Digitisers for the CERN Beam Loss Systems

    CERN Document Server

    Vigano, W; Dehning, B; Kwiatkowski, M; Venturini, G G; Zamantzas, C

    2014-01-01

    A wide range current digitizer card is needed for the acquisition module of the beam loss monitoring systems in the CERN Injector Complex. The fully differential frequency converter allows measuring positive and negative input currents with a resolution of 31nA in an integration window of 2μs. Increasing the integration window, the dynamic range covers 2•1010 were the upper part of the range is converted by measuring directly the voltage drop on a resistor. The key elements of this design are the fully differential integrator and the switches operated by an FPGA. The circuit is designed to avoid any dead time in the acquisition and reliability and failsafe operational considerations are main design goals. The circuit will be discussed in detail and lab and field measurements will be shown.

  3. Optical alignment and characterization of the radial neutron beam duct number 4 of de RP-10 nuclear reactor

    International Nuclear Information System (INIS)

    We show the process of optical axis alignment of the neutrography device and the optical axis of the neutron beam from the radial duct number 4 of the RP-10 Nuclear Reactor, using optical methods, assisted by radiography, which facilitates the location of the optical axis of the neutron beam by the photographic recording of the space, allowing the alignment of the neutrography plate later. In the process, the location and orientation of the source depends on the placement of the fuel elements immersed inside the duct and between the core and the collimator in the Nuclear Reactor wall. This part of the process depends on the reactor operating personnel who calculate optimally the fuel burn and perform the analysis of the spatial distribution of radiation. The power measurement and the final adjustment of the optical axis of the neutron beam with the optical axis of the instrument are shown in this paper, which will make possible neutrography experiments, as well as neutron diffraction, neutron spectroscopy and neutron optics among others. (orig.)

  4. Demonstration of electronic pattern switching and 10x pattern demagnification in a maskless micro-ion beam reduction lithography system

    International Nuclear Information System (INIS)

    A proof-of-principle ion projection lithography (IPL) system called Maskless Micro-ion beam Reduction Lithography (MMRL) has been developed and tested at the Lawrence Berkeley National Laboratory (LBNL) for future integrated circuits (ICs) manufacturing and thin film media patterning [1]. This MMRL system is aimed at completely eliminating the first stage of the conventional IPL system [2] that contains the complicated beam optics design in front of the stencil mask and the mask itself. It consists of a multicusp RF plasma generator, a multi-beamlet pattern generator, and an all-electrostatic ion optical column. Results from ion beam exposures on PMMA and Shipley UVII-HS resists using 75 keV H+ are presented in this paper. Proof-of-principle electronic pattern switching together with 10x reduction ion optics (using a pattern generator made of nine 50-(micro)m switchable apertures) has been performed and is reported in this paper. In addition, the fabrication of a micro-fabricated pattern generator [3] on an SOI membrane is also presented

  5. Demonstration of electronic pattern switching and 10x pattern demagnification in a maskless micro-ion beam reduction lithography system

    International Nuclear Information System (INIS)

    A proof-of-principle ion projection lithography (IPL) system called Maskless Micro-ion beam Reduction Lithography (MMRL) has been developed and tested at the Lawrence Berkeley National Laboratory (LBNL) for future integrated circuits (ICs) manufacturing and thin film media patterning[1]. This MMRL system is aimed at completely eliminating the first stage of the conventional IPL system[2] that contains the complicated beam optics design in front of the stencil mask and the mask itself. It consists of a multicusp RF plasma generator, a multi-beamlet pattern generator, and an all-electrostatic ion optical column. Results from ion beam exposures on PMMA and Shipley UVII-HS resists using 75 keV H+ are presented in this paper. Proof-of-principle electronic pattern switching together with 10x reduction ion optics (using a pattern generator made of nine 50-(micro)m switchable apertures) has been performed and is reported in this paper. In addition, the fabrication of a micro-fabricated pattern generator[3] on an SOI membrane is also presented

  6. Cationic concentration effects on electron beam cured of carbon-epoxy composites

    International Nuclear Information System (INIS)

    Electron beam (e-beam) curing is a technology that offers advantages over the thermal curing process, that usually requires high temperature and are time-consuming. E-beam curing is faster and occurs at low temperatures that help reduce residual mechanical stresses in a thermoset composite. The aim of the present study is to analyze the effects of cationic initiator (diaryliodonium hexafluoroantimonate) ranged from 1 to 3 wt% in DGEBA (diglycidyl ether of bisphenol A) epoxy resin when cured by a 1.5 MeV electron beam. The specimens were cured to a total dose of 200.4 kGy for 40 min. Analyses by dynamic mechanical thermal analysis (DMTA) and differential scanning calorimetry (DSC) show that the e-beam irradiated samples with 2 wt% cationic initiator were 96% cured obtained a glass transition temperature (tan δ) of 167 deg. C. The same epoxy resin, thermally cured for 16 h with an anhydride hardener, reached a Tg (tan δ) of 136 deg. C. So, the irradiated sample had its Tg increased approximately 20% and the curing process was much less time consuming.

  7. Cationic concentration effects on electron beam cured of carbon-epoxy composites

    Energy Technology Data Exchange (ETDEWEB)

    Nishitsuji, D.A., E-mail: delmo_amari@yahoo.com.b [Brazilian Navy Technological Center, Sao Paulo (Brazil); Marinucci, G. [Brazilian Navy Technological Center, Sao Paulo (Brazil); Energetic and Nuclear Research Institute-IPEN-CNEN/SP, Av. Prof. Lineu Prestes, 2242-Cidade Universitaria, 05508-000 Sao Paulo/SP (Brazil); Evora, M.C. [Institute of Advanced Studies/CTA, Sao Jose dos Campos/SP (Brazil); Silva, L.G.A. [Energetic and Nuclear Research Institute-IPEN-CNEN/SP, Av. Prof. Lineu Prestes, 2242-Cidade Universitaria, 05508-000 Sao Paulo/SP (Brazil)

    2010-03-15

    Electron beam (e-beam) curing is a technology that offers advantages over the thermal curing process, that usually requires high temperature and are time-consuming. E-beam curing is faster and occurs at low temperatures that help reduce residual mechanical stresses in a thermoset composite. The aim of the present study is to analyze the effects of cationic initiator (diaryliodonium hexafluoroantimonate) ranged from 1 to 3 wt% in DGEBA (diglycidyl ether of bisphenol A) epoxy resin when cured by a 1.5 MeV electron beam. The specimens were cured to a total dose of 200.4 kGy for 40 min. Analyses by dynamic mechanical thermal analysis (DMTA) and differential scanning calorimetry (DSC) show that the e-beam irradiated samples with 2 wt% cationic initiator were 96% cured obtained a glass transition temperature (tan delta) of 167 deg. C. The same epoxy resin, thermally cured for 16 h with an anhydride hardener, reached a T{sub g} (tan delta) of 136 deg. C. So, the irradiated sample had its T{sub g} increased approximately 20% and the curing process was much less time consuming.

  8. Management of the installation of a 10 MeV, 50 kW electron-beam irradiator

    International Nuclear Information System (INIS)

    An IMPELA-10/50 electron-beam irradiator has been installed by AECL Accelerators in Iotron Industries' service centre near Vancouver. Construction of the facility, installation of the accelerator and conveyor, and commissioning to the full rated power of 50 kW were completed in 12 months. Iotron began commercial irradiation immediately and the first continuous operation achieved 250 hours of production in 12 days. The engineering, production and project management organizations and activities to complete the on-schedule installation and commissioning are reviewed. (author). 3 refs., 2 tabs., 1 fig

  9. Sci—Sat AM: Stereo — 04: Evaluation of VMAT interplay effect for lung SABR using TrueBeam 10XFFF beam

    Energy Technology Data Exchange (ETDEWEB)

    Huang, V; Thomas, SD [BC Cancer Agency, Fraser Valley Cancer Centre (Canada); Teke, T [BC Cancer Agency, Centre for the Southern Interior (Canada)

    2014-08-15

    During a VMAT treatment delivery, the interplay effect between the moving target and varying machine parameters result in dose distributions that are different from those initially planned. In this work, we investigate this effect for lung SABR by using 4D dose calculation derived from the Varian TrueBeam trajectory log file. The impact of treatment start phase is also evaluated. A QUASAR™ respiratory motion phantom was scanned with motion amplitudes of 0.4, 1, 2 and 3 cm with a 4 second period. MIP and the average dataset were generated from the 4DCT. A static CT was also acquired with the tumor in its centre position. Plans were optimized with 10X FFF beam until PTV and fictitious critical structures met the dose constraints. Ten temporally interleaved plans were constructed with the temporal machine parameter information from the trajectory log file. Ten plans were calculated with isocentre shifts to simulate respiratory motion and then summed. For each motion amplitude, three separate sum plans were created with various phase shifts (no phase shift, maximum inhalation and maximum exhalation) to assess the impact of treatment start phase. For all the phase shifts investigated, the DVH for PTV demonstrated good dose coverage. However, a careful review of slice by slice plan comparison indicates dose “holes” are observed within PTV. The PTV dose difference between various treatment start phases can be as high as 19%. This assumes all treatment fractions have identical treatment start phase. Our future work includes evaluation of interplay effect for various breathing periods.

  10. Sci—Sat AM: Stereo — 04: Evaluation of VMAT interplay effect for lung SABR using TrueBeam 10XFFF beam

    International Nuclear Information System (INIS)

    During a VMAT treatment delivery, the interplay effect between the moving target and varying machine parameters result in dose distributions that are different from those initially planned. In this work, we investigate this effect for lung SABR by using 4D dose calculation derived from the Varian TrueBeam trajectory log file. The impact of treatment start phase is also evaluated. A QUASAR™ respiratory motion phantom was scanned with motion amplitudes of 0.4, 1, 2 and 3 cm with a 4 second period. MIP and the average dataset were generated from the 4DCT. A static CT was also acquired with the tumor in its centre position. Plans were optimized with 10X FFF beam until PTV and fictitious critical structures met the dose constraints. Ten temporally interleaved plans were constructed with the temporal machine parameter information from the trajectory log file. Ten plans were calculated with isocentre shifts to simulate respiratory motion and then summed. For each motion amplitude, three separate sum plans were created with various phase shifts (no phase shift, maximum inhalation and maximum exhalation) to assess the impact of treatment start phase. For all the phase shifts investigated, the DVH for PTV demonstrated good dose coverage. However, a careful review of slice by slice plan comparison indicates dose “holes” are observed within PTV. The PTV dose difference between various treatment start phases can be as high as 19%. This assumes all treatment fractions have identical treatment start phase. Our future work includes evaluation of interplay effect for various breathing periods

  11. Formation and atomic structure of tetrahedral carbon onion produced by electron-beam irradiation

    International Nuclear Information System (INIS)

    Full text: Various fullerene structures has been designed and produced after the discovery of C60. These fullerene materials are good candidates as nanoscale devises such as single-electron devices, nano-diode, nano-transistor, nano-ball bearing and insulator lubricant. The onion structures, which generally consist of some quasi-spherical fullerene group, are also discovered and studied in detail. The tetrahedral carbon onions had been calculated to be unstable compared to the spherical onions due to the rigidity. The purpose of the present work is to produce new carbon onion by high-energy electron-irradiation on amorphous carbon at 1250 kV, and to investigate atomic structures and stability of the new carbon onion cluster by high-resolution electron microscopy (HREM) and molecular orbital/mechanics calculations. To confirm the structure model from HREM data, HREM image simulation were carried out. The tetrahedral carbon onion was successfully produced by high-energy electron-irradiation. A HREM image of tetrahedral carbon onion would consist of pentagonal and hexagonal rings. The HREM result indicates that new fullerene structures formed into the carbon onion. Molecular mechanics calculations (MM2), semi-empirical molecular orbital calculations (PM3), and density functional theory (DFT) were used to get structure optimization about first and second internal shell. The energy levels and density of states were also calculated by the first principles method (DV-Xα). The smallest tetrahedral onion in the HREM image agreed well with the proposed structure model of C84atC276. Each vertex consists of a hexagonal ring, and three pentagonal rings exist around the vertex along the edge. In summary, the tetrahedral carbon cluster was produced by energy transfer of electron-irradiation, and the new atomic structure model of tetrahedral carbon onion was proposed. The electronic structures were also calculated theoretically. Copyright (2002) Australian Society for Electron

  12. Chemical investigations of isotope separation on line target units for carbon and nitrogen beams

    CERN Document Server

    Franberg, H; Gäggeler, H W; Köster, U

    2006-01-01

    Radioactive ion beams (RIBs) are of significant interest in a number of applications. Isotope separation on line (ISOL) facilities provide RIB with high beam intensities and good beam quality. An atom that is produced within the ISOL target will first diffuse out from the target material. During the effusion towards the transfer line and into the ion source the many contacts with the surrounding surfaces may cause unacceptable delays in the transport and, hence, losses of the shorter-lived isotopes. We performed systematic chemical investigations of adsorption in a temperature and concentration regime relevant for ISOL targets and ion source units, with regard to CO/sub x/ and NOmaterials are potential construction materials for the above-mentioned areas. Off-line and on-line tests have been performed using a gas thermochromatography setup with radioactive tracers. The experiments were performed at the production of tracers for atmospheric chemistry (PROTRAC) facility at the Paul Schener Institute in Villigen...

  13. Ribbon target assembly using carbon graphite for secondary emission type beam profile monitor

    International Nuclear Information System (INIS)

    We developed a secondary emission type beam profile monitor with graphite ribbons as a beam target. The graphite is excellent in endurance against heat load, and that they are thin as 1.6-2.0 micron and low z (=6) is advantage for reducing beam loss. Furthermore, since ribbons emits larger amount of electrons than ordinal metal wires because of larger surface, the monitor has higher sensitivity. On the other hands, in case of multi-ribbon type, uniformity of secondary electron emission is required for accurate measurement. For the uniform emission, not only surface homogeneity, but also evenness for each ribbon width is needed. A suitable manufacturing method to make ribbon target from graphite-foil, and emission uniformity has been studied. (author)

  14. A scintillating gas detector for 2D dose measurements in clinical carbon beams

    International Nuclear Information System (INIS)

    A two-dimensional position sensitive dosimetry system based on a scintillating gas detector has been developed for pre-treatment verification of dose distributions in hadron therapy. The dosimetry system consists of a chamber filled with an Ar/CF4 scintillating gas mixture, inside which two cascaded gas electron multipliers (GEMs) are mounted. A GEM is a thin kapton foil with copper cladding structured with a regular pattern of sub-mm holes. The primary electrons, created in the detector's sensitive volume by the incoming beam, drift in an electric field towards the GEMs and undergo gas multiplication in the GEM holes. During this process, photons are emitted by the excited Ar/CF4 gas molecules and detected by a mirror-lens-CCD camera system. Since the amount of emitted light is proportional to the dose deposited in the sensitive volume of the detector by the incoming beam, the intensity distribution of the measured light spot is proportional to the 2D hadron dose distribution. For a measurement of a 3D dose distribution, the scintillating gas detector is mounted at the beam exit side of a water-bellows phantom, whose thickness can be varied in steps. In this work, the energy dependence of the output signal of the scintillating gas detector has been verified in a 250 MeV/u clinical 12C ion beam by means of a depth-dose curve measurement. The underestimation of the measured signal at the Bragg peak depth is only 9% with respect to an air-filled ionization chamber. This is much smaller than the underestimation found for a scintillating Gd2O2S:Tb ('Lanex') screen under the same measurement conditions (43%). Consequently, the scintillating gas detector is a promising device for verifying dose distributions in high LET beams, for example to check hadron therapy treatment plans which comprise beams with different energies

  15. A scintillating gas detector for 2D dose measurements in clinical carbon beams

    Science.gov (United States)

    Seravalli, E.; de Boer, M.; Geurink, F.; Huizenga, J.; Kreuger, R.; Schippers, J. M.; van Eijk, C. W. E.; Voss, B.

    2008-09-01

    A two-dimensional position sensitive dosimetry system based on a scintillating gas detector has been developed for pre-treatment verification of dose distributions in hadron therapy. The dosimetry system consists of a chamber filled with an Ar/CF4 scintillating gas mixture, inside which two cascaded gas electron multipliers (GEMs) are mounted. A GEM is a thin kapton foil with copper cladding structured with a regular pattern of sub-mm holes. The primary electrons, created in the detector's sensitive volume by the incoming beam, drift in an electric field towards the GEMs and undergo gas multiplication in the GEM holes. During this process, photons are emitted by the excited Ar/CF4 gas molecules and detected by a mirror-lens-CCD camera system. Since the amount of emitted light is proportional to the dose deposited in the sensitive volume of the detector by the incoming beam, the intensity distribution of the measured light spot is proportional to the 2D hadron dose distribution. For a measurement of a 3D dose distribution, the scintillating gas detector is mounted at the beam exit side of a water-bellows phantom, whose thickness can be varied in steps. In this work, the energy dependence of the output signal of the scintillating gas detector has been verified in a 250 MeV/u clinical 12C ion beam by means of a depth-dose curve measurement. The underestimation of the measured signal at the Bragg peak depth is only 9% with respect to an air-filled ionization chamber. This is much smaller than the underestimation found for a scintillating Gd2O2S:Tb ('Lanex') screen under the same measurement conditions (43%). Consequently, the scintillating gas detector is a promising device for verifying dose distributions in high LET beams, for example to check hadron therapy treatment plans which comprise beams with different energies.

  16. Pre Design of Beam Parameter Control System for Electron Beam Machine (EBM) 350 keV/10 mA in the Center for Accelerator and Material Process Technology - BATAN Yogyakarta

    International Nuclear Information System (INIS)

    Pre design of beam parameter control system for Electron Beam Machine (EBM) 350 keV/10 mA had an objective to find a control system algorithm for EBM in The Center For Accelerator and Material Process Technology (Pusat Teknologi dan Proses Bahan/PTAPB) - BATAN Yogyakarta. The design was based on the beam parameter model of EBM. The model shown a relationship between the dose parameter setting and the beam energy setting which it was being a problem in setting the beam parameters.The control system algorithm was found by getting compensator equations from the beam parameter model of EBM. The equations would omit the relation between the radiation dose parameter and beam energy parameter, so that the parameters could be adjusted easily. The result of the control system algorithm examine based on simulation shown that the setting of beam parameter value could be done by giving the accelerating voltage value and the filament current value as the operator had determined the value. The value of radiation dose and beam energy would be adjusted as its function of the filament current value and the accelerating voltage value. (author)

  17. Beam-Port Design of a Radiobiological Dosimetry Experiment for 10B-Enhanced 252Cf Brachytherapy

    International Nuclear Information System (INIS)

    It has been previously suggested that the incorporation of 10B-labeled drugs into tumor cells might significantly increase the dose to the peripheral tumor cells in 252Cf brachytherapy. The dose enhancement comes from the thermal neutron capture reactions of 10B(n, α)7Li. As a new cancer treatment modality, this so-called 10und B-und Enhanced 252und Cf und Brachyund therapy (BECBT) is currently being commercialized by Isotron. One of the challenges for implementing BECBT has been to determine the maximum tolerable dose (MTD) to the normal tissue surrounding a tumor. Because the relative biological effectiveness for the 10B(n, α)7Li reaction products is greater than that for fission neutrons, the MTD should decrease as 10B concentration increases for BECBT. To more precisely determine the MTD for BECBT, we intend to conduct both in vitro (cell culture) and in vivo (rat) experiments with a 50-mg 252Cf source. We will use cell survival fraction and normal brain necrosis as the biological end points for the cell-culture experiments and rat experiments, respectively. To carry out these experiments, the neutron field to which the samples are exposed must contain a significant portion of thermal neutrons. The rat experiments further require the use of a very small and well-collimated neutron beam to effectively irradiate the rat brain while minimizing the dose to its whole body. This paper discusses the design criteria for the experimental neutron beam port and the computational work leading to its optimal configuration

  18. A Study of Charged Current Single Charged Pion Productions on Carbon in a Few-GeV Neutrino Beam

    Energy Technology Data Exchange (ETDEWEB)

    Hiraide, Katsuki; /Kyoto U.

    2009-01-01

    Understanding single charged pion production via neutrino-nucleus charged current interaction in the neutrino energy region of a few GeV is essential for future neutrino oscillation experiments since this process is a dominant background for {nu}{sub {mu}} {yields} {nu}{sub x} oscillation measurements. There are two contributions to this process: single pion production via baryonic resonance ({nu}{sub {mu}}N {yields} {mu}{sup -} N{pi}{sup +}) and coherent pion production interacting with the entire nucleus ({nu}{sub {mu}}A {yields} {mu}{sup -} A{pi}{sup +}), where N is nucleon in the nucleus and A is the nucleus. The purpose of the study presented in this thesis is a precise measurement of charged current single charged pion productions, resonant and coherent pion productions, with a good final state separation in the neutrino energy region of a few GeV. In this thesis, we focus on the study of charged current coherent pion production from muon neutrinos scattering on carbon, {nu}{sub {mu}} {sup 12}C {yields} {mu}{sup -12}C{pi}{sup +}, in the SciBooNE experiment. This is motivated by the fact that without measuring this component first, the precise determination of resonant pion production cross section can not be achieved since the contribution of coherent pion production in the region of small muon scattering angle is not small. Furthermore, the coherent process is particularly interesting because it is deeply rooted in fundamental physics via Adler's partially conserved axial-vector current theorem. We took data from June 2007 until August 2008, in both the neutrino and antineutrino beam. In total, 2.52 x 10{sup 20} protons on target were collected. We have performed a search for charged current coherent pion production by using SciBooNE's full neutrino data set, corresponding to 0.99 x 10{sup 20} protons on target. No evidence for coherent pion production is observed. We set 90% confidence level upper limits on the cross section ratio of charged

  19. A Study of Charged Current Single Charged Pion Productions on Carbon in a Few-GeV Neutrino Beam

    Energy Technology Data Exchange (ETDEWEB)

    Hiraide, Katsuki [Kyoto Univ. (Japan)

    2009-01-01

    Understanding single charged pion production via neutrino-nucleus charged current interaction in the neutrino energy region of a few GeV is essential for future neutrino oscillation experiments since this process is a dominant background for vμ → vx oscillation measurements. There are two contributions to this process: single pion production via baryonic resonance (vμN → μ-+) and coherent pion production interacting with the entire nucleus (vμA → μ-+), where N is nucleon in the nucleus and A is the nucleus. The purpose of the study presented in this thesis is a precise measurement of charged current single charged pion productions, resonant and coherent pion productions, with a good final state separation in the neutrino energy region of a few GeV. In this thesis, we focus on the study of charged current coherent pion production from muon neutrinos scattering on carbon, vμ 12C → μ-12+, in the SciBooNE experiment. This is motivated by the fact that without measuring this component first, the precise determination of resonant pion production cross section can not be achieved since the contribution of coherent pion production in the region of small muon scattering angle is not small. Furthermore, the coherent process is particularly interesting because it is deeply rooted in fundamental physics via Adler's partially conserved axial-vector current theorem. We took data from June 2007 until August 2008, in both the neutrino and antineutrino beam. In total, 2.52 x 1020 protons on target were collected. We have performed a search for charged current coherent pion production by using SciBooNE's full neutrino data set, corresponding to 0.99 x 1020 protons on target. No evidence for coherent pion production is observed. We set 90% confidence level upper limits on the cross section ratio

  20. MODIFICATION OF CARBON STEEL BY LASER SURFACE MELTING: PART II: EFFECT OF LASER BEAM POWER ON MICROSTRUCTURAL FEATURES AND SURFACE HARDNESS

    OpenAIRE

    Hashem F. El-Labban; Abdelaziz, M.; Essam R.I. Mahmoud

    2013-01-01

    The surface hardness has an important effect on the wear resistance of different materials. The present study aims to improve the surface hardness of carbon steel through the application of laser surface melting with suitable conditions. The laser beam power and travelling speed are the main factors that affect the properties of the treated zone. In this study, three different conditions of laser beam power (1800, 1500 and 1200 W) at fixed travelling speed of 1000 mm min-1 were chosen to stud...

  1. Monte Carlo Simulation for Neptun 10 PC medical linear accelerator and calculations of electron beam parameters

    International Nuclear Information System (INIS)

    In recent decades, cancer has been one of the main ever increasing causes of death in developed countries. In order to fulfill the aforementioned considerations different techniques have been used, one of which is Monte Carlo simulation technique. High accuracy of the Monte Carlo simulation has been one of the main reason for its wide spread application. In this study, MCNP-4C code was employed to simulate electron mode of the Neptun 10 PC Linac, dosimetric quantities for conventional fields have also been both measured and calculated. Although Neptun 10 PC Linac is no longer licensed for installation in European and some other countries but regrettably nearly 10 of them have been installed in different centers around the country and are in operation. Therefore, in this circumstance, to improve the accuracy of treatment planning, Monte Carlo simulation for Neptun 10 PC was recognized as a necessity. Simulated and measured values of depth dose curves, off axis dose distributions for 6 , 8 and 10 MeV electrons applied for four different size fields, 6 x 6 cm2, 10 x 10 cm2, 15 x 15 cm2 and 20 x 20 cm2 were obtained. The measurements were carried out by a Welhofer-Scanditronix dose scanning system, Semiconductor Detector and Ionization Chamber. The results of this study have revealed that the values of two main dosimetric quantities depth dose curves and off axis dose distributions, acquired by MCNP-4C simulation and the corresponding values achieved by direct measurements are in a very good agreement (within 1% to 2% difference). In general, very good consistency of simulated and measured results, is a good proof that the goal of this work has been accomplished. In other word where measurements of some parameters are not practically achievable, MCNP-4C simulation can be implemented confidently. (author)

  2. Optical diagnostic suite (schlieren, interferometry, and grid image refractometry) on OMEGA EP using a 10-ps, 263-nm probe beam

    Energy Technology Data Exchange (ETDEWEB)

    Froula, D. H.; Boni, R.; Bedzyk, M.; Craxton, R. S.; Ehrne, F.; Ivancic, S.; Jungquist, R.; Shoup, M. J.; Theobald, W.; Weiner, D. [Laboratory for Laser Energetics, University of Rochester, 250 E. River Rd., Rochester, New York 14616 (United States); Kugland, N. L.; Rushford, M. C. [Lawrence Livermore National Laboratory, University of California, P. O. Box 808, Livermore, California 94551 (United States)

    2012-10-15

    A 10-ps, 263-nm (4{omega}) laser is being built to probe plasmas produced on the OMEGA EP [J. H. Kelly, L. J. Waxer, V. Bagnoud, I. A. Begishev, J. Bromage, B. E. Kruschwitz, T. E. Kessler, S. J. Loucks, D. N. Maywar, R. L. McCrory et al., J. Phys. IV France 133, 75-80 (2006)]. A suite of optical diagnostics (schlieren, interferometry, and grid image refractometry) has been designed to diagnose and characterize a wide variety of plasmas. Light scattered by the probe beam is collected by an f/4 catadioptric telescope and a transport system is designed to image with a near-diffraction-limited resolution ({approx}1 -{mu}m full width at half maximum) over a 5-mm field of view to a diagnostic table. The transport system provides a contrast greater than 1 : 10{sup 4} with respect to all wavelengths outside of the 263 {+-} 2 nm measurement range.

  3. Mutation induction by gamma-rays and carbon ion beam irradiation in banana (Musa spp.): a study with an emphasis on the response to Black sigatoka disease

    International Nuclear Information System (INIS)

    Gamma-rays and carbon ion beam irradiation methods were applied to study critical doses, genetic variability and the response to Black sigatoka disease. 'Cavendish Enano', 'Williams', 'Orito' and 'FHIA-01' cultivars of banana were studied. Both gamma-rays and carbon ion beam irradiation methods had different biological effects when banana explants were exposed to them. In both methods, increased dose caused increased mortality. 'FHIA-01' tolerated high doses of gamma-rays but was susceptible to high doses of carbon ion beam irradiation. The results suggest that the response in 'FHIA-01' can be explored using other dose intervals between 150 and 300 Gy. Weight and height were also reduced drastically when high doses of gamma-rays and carbon ion beams were applied. The LD50 of cultivars 'FHIA-01' and 'Orito' revealed high sensitivity to both gamma-rays and carbon ion beams. DNA deletion in 'FHIA-01' occurred by using gamma-rays at doses of 200 and 300 Gy, suggesting that 'FHIA-01' is definitely a promising cultivar with a high sensitivity response to gamma-ray exposure, and that there is a high chance of improving its fruit quality by mutation induction. Sigmoid drooping leaf, a putative mutation of 'FHIA-01', was generated. This mutation is heritable as mother plant and sucker showed the same characteristics. Future research could be conducted on the relationship of leaf shape to fruit quality and production. Hexaploid cells were detected by flow cytometry (five plants in 'Cavendish Enano' and one in 'Williams'), signifying that chromosome duplication can be induced by carbon ion beams. Variation in the leaves such as being abnormal, double, long, rudimentary, spindled and yellow spotted leaf was visible, suggesting that long-term chronic irradiation (gamma-rays) directly affects active cell division at the meristem level, resulting in severe damage or even death of the meristems. During the juglone toxin experiment on gamma-ray-irradiated plants, 20 plants were

  4. Effect of Ag addition to L10 FePt and L10 FePd films grown by molecular beam epitaxy

    International Nuclear Information System (INIS)

    L10 ordered FePt-Ag (5 nm) and FePd-Ag (5 nm) films were grown on MgO (001) substrate at temperatures of 250–400 °C by using molecular beam epitaxy method, and their crystal and surface structures, perpendicular magnetic anisotropies and Curie temperatures were investigated. In the case of FePt-Ag, Ag addition with the amount of 10–20 at. % was effective to promote L10 ordering and granular growth, resulting in the increase of the perpendicular magnetic anisotropy and coercivity of the FePt-Ag films. On the other hand, in the case of FePd-Ag, Ag addition changed the surface morphology from island to continuous film associated with the reductions of its coercivity and perpendicular anisotropy. The variations of lattice constants and Curie temperature with Ag addition were significantly different between FePt-Ag and FePd-Ag. For FePd-Ag, the c and a axes lattice spacings and Curie temperature gradually changed with increasing Ag content, while they unchanged for FePt-Ag. These results suggest the possibility of the formation of FePdAg alloy in FePd-Ag, while Ag segregation in FePt-Ag

  5. 3–10 keV Xe+ ion beam machining of ultra low thermal expansion glasses for EUVL projection optics: Evaluation of surface roughness

    International Nuclear Information System (INIS)

    In order to obtain surface figure error of 0.15 nm rms and surface roughness (Rrms) of 0.12 nm rms for aspherical substrates in EUVL tools, ion beam figuring may be adopted to final surface figure error correction of aspherical substrates. During figure error correction, machined surface of the substrate becomes rougher than the pre-finished one. Therefore, we investigated the machined depth and ion energy dependences of Rrms (measured by an AFM) of substrates machined by 3–10 keV Xe+ ion beam, and compared them with the results obtained for Ar+ ion beam. Result shows that the Rrmss of CLEARCERAM®-Z, Zerodur® and ULE® substrates machined to the depth of 50 nm by 3–10 keV Xe+ ion beam at the normal ion incidence angle become approximately 0.25, 0.28 and 0.15 nm rms, respectively. Those values are larger than the pre-finished substrates (0.07–0.09 nm rms), but smaller than that (0.60 nm rms for CLEARCERAM®-Z, 0.61 nm rms for Zerodur® and 0.18 nm rms for ULE®) of the substrates machined by Ar+ ion beam. Moreover, the Rrmss merely increase with increasing ion energy. The Rrmss of the ULE® substrate machined by 3–10 keV Xe+ ion beam rapidly increase with increasing machined depth, then saturate at machined depth of 10–50 nm. The saturated values of the Rrmss are 0.12 and 0.15 nm rms for 3 and 10 keV Xe+ ion beam respectively. We suggest that the 3 keV Xe+ ion beam machining can be applicable for final shape correction of ULE® substrates for EUVL projection optics in association with considering further ultra smoothing process such as Si deposition or low energy ion beam smoothing.

  6. Beam induced annealing of damage in carbon implanted silicon, ch. 4

    International Nuclear Information System (INIS)

    The annealing of damage introduced by 70 keV C implantation of Si is studied for impact of H+ and He+ beams in the energy interval 30 - 200 keV. For a good description of the annealing behaviour it is necessary to account for the damage introduction which occurs simultaneously. It turns out that the initial damage annealing rate is proportional to the amount of damage. The proportionality constant is related to the quantity fsub(a)sigmasub(a) introduced in an earlier paper in order to describe saturation effects in the damage production after H+ or He+ impact in unimplanted Si. This indicates that the same mechanism governs both processes: beam induced damage annealing and saturation of the damage introduction. (Auth.)

  7. Selective radiography of 10B distribution in organs using cold and thermal neutron beams

    International Nuclear Information System (INIS)

    The investigation of boron biodistribution by neutron induced autoradiography was performed using a CR-39 etched track detector. Calibration samples, made of boronated chicken liver, and freeze-dried mouse tissue samples were irradiated both with thermal and cold neutrons. Digital images were made on the basis of track densities, with the selection of tracks due to 10B(n, α) 7Li reaction. A comparison of results obtained both with thermal and cold neutrons demonstrated that it is possible to obtain equivalent results with both neutron sources, although the background noise due to recoil protons from the fast neutrons of the thermal neutron source is 15% higher than that of the cold neutron source. 10B concentrations in the range of 0.5 ppm to 150 ppm were determined, with a standard deviation of 13% and 8% for the mouse tissue samples and calibration samples, respectively. (author)

  8. Chemical Investigations of ISOL target units for carbon and nitrogen beams

    CERN Document Server

    Franberg, H; Gäggeler, H W; Köster, U

    2006-01-01

    Radioactive Ion Beams (RIB) are of significant interest in a number of applications. ISOL (Isotope Separation On Line) facilities provide RIB with high beam intensities and good beam quality. An atom that is produced within the ISOL target will first diffuse out from the target material. During the effusion towards the transfer line and into the ion source the many contacts with the surrounding surfaces may cause unacceptable delays in the transport and, hence, losses of the shorter-lived isotopes. We performed systematic chemical investigations of adsorption in a temperature and concentration regime relevant for ISOL targets and ion source units, with regard to COx and NOx on Al2O3 and SiO2. These materials are potential construction materials for the above mentioned areas. Off-line and on-line tests have been performed using a gas thermo-chromatography set-up with radioactive tracers. The experiments were performed at the PROTRAC facility at Paul Scherrer Institute in Villigen, Switzerland.

  9. Inferring phytoplankton carbon and eco-physiological rates from diel cycles of spectral particulate beam-attenuation coefficient

    Directory of Open Access Journals (Sweden)

    G. Dall'Olmo

    2011-03-01

    Full Text Available The diurnal fluctuations in solar irradiance impose a fundamental frequency on ocean biogeochemistry. Observations of the ocean carbon cycle at these frequencies are rare, but could be considerably expanded by measuring and interpreting the inherent optical properties. A method is presented to analyze diel cycles in particulate beam-attenuation coefficient (cp measured at multiple wavelengths. The method is based on fitting observations with a size-structured population and optical model to infer the particle size distribution and physiologically relevant parameters of the cells responsible for the measured diel cycle in cp. Results show that the information related to size and contained in the spectral data can be exploited to independently estimate growth and loss rates during the day and night. In addition, the model can characterize the population of particles affecting the cp diel variability. Application of this method to spectral cp measured at a station in the oligotrophic Mediterranean Sea suggests that most of the observed variations in cp can be ascribed to a synchronized population of cells with an equivalent spherical diameter between 1 and 4 μm. The inferred carbon biomass of these cells was about 8–13 mg m−3 and accounted for approximately 20% of the total particulate organic carbon. If successfully validated and implemented on autonomous platforms, this method could improve our understanding of the ocean carbon cycle.

  10. Rapid phase-correlated rescanning irradiation improves treatment time in carbon-ion scanning beam treatment under irregular breathing

    Science.gov (United States)

    Mori, Shinichiro; Furukawa, Takuji

    2016-05-01

    To shorten treatment time in pencil beam scanning irradiation, we developed rapid phase-controlled rescanning (rPCR), which irradiates two or more isoenergy layers in a single gating window. Here, we evaluated carbon-ion beam dose distribution with rapid and conventional PCR (cPCR). 4 dimensional computed tomography (4DCT) imaging was performed on 12 subjects with lung or liver tumors. To compensate for intrafractional range variation, the field-specific target volume (FTV) was calculated using 4DCT within the gating window (T20–T80). We applied an amplitude-based gating strategy, in which the beam is on when the tumor is within the gating window defined by treatment planning. Dose distributions were calculated for layered phase-controlled rescanning under an irregular respiratory pattern, although a single 4DCT data set was used. The number of rescannings was eight times. The prescribed doses were 48 Gy(RBE)/1 fr (where RBE is relative biological effectiveness) delivered via four beam ports to the FTV for the lung cases and 45 Gy(RBE)/2 fr delivered via two beam ports to the FTV for the liver cases. In the liver cases, the accumulated dose distributions showed an increased magnitude of hot/cold spots with rPCR compared with cPCR. The results of the dose assessment metrics for the cPCR and rPCR were very similar. The D 95, D max, and D min values (cPCR/rPCR) averaged over all the patients were 96.3  ±  0.9%/96.0  ±  1.2%, 107.3  ±  3.6%/107.1  ±  2.9%, and 88.8  ±  3.2%/88.1  ±  3.1%, respectively. The treatment times in cPCR and rPCR were 110.7 s and 53.5 s, respectively. rPCR preserved dose conformation under irregular respiratory motion and reduced the total treatment time compared with cPCR.

  11. Determination of the size distribution of carbon and trace elements in suspended particulate matter by ion beam analysis

    International Nuclear Information System (INIS)

    The size distribution of carbon and trace elements in suspended particulate matter (SPM) collected by a low pressure impactor has been investigated. Sampling was carried out at Setagaya, a typical residential area located southwest of Tokyo, Japan. The low pressure impactor has a cascade design with 12-stage collection plates, allowing the collection of size-fractionated SPM. It operates at a flow rate of 20 l/min. Elemental composition was determined by ion beam analysis, particle induced X-ray emission (PIXE) and Rutherford backscattering (RBS). PIXE provided data for elements from Al to U while RBS supplied information on elements lighter than Al such as C and O. The analysis is fast, non-destructive and requires no sample preparation. It is very suitable for determination of elements in SPM. In this paper we discuss size distribution and element concentrations in SPM together with their weekly and seasonal variations

  12. Preparation of diamond-like carbon and boron nitirde films by high-intensity pulsed ion beam deposition

    Energy Technology Data Exchange (ETDEWEB)

    Rej, D.J.; Davis, H.A. [Los Alamos National Lab., NM (United States); Remnev, G.E. [Tomsk Polytechnic Univ., Tomsk (Russian Federation). Nuclear Physics Institute.] [and others

    1995-05-01

    Intense ion beams (300-keV C{sup +}, O{sup +}, and H{sup +}, 20--30 kA, 50 to 400-ns pulsewidth, up to 0.3-Hz repetition rate) were used to prepare diamond-like carbon (DLC) and boron nitride (BN) films. Deposition rates of up to 25{plus_minus}5 nm/pulse were obtained with instantaneous rates exceeding 1 mm/s. Most films were uniform, light brown, translucent, and nonporous with some micron-size particulates. Raman and parallel electron energy loss spectroscopy indicated the presence of DLC. The films possessed favorable electron field-emission characteristics desirable for cold-cathode displays. Transmission electron microscopy (TEM) and transmission electron diffraction (TED) revealed that the C films contained diamond crystals with 25 to 125-nm grain size. BN films were composed of hexagonal, cubic and wurtzite phases.

  13. Radiosensitivity of cancer cells against carbon-ion beams in an aspect of the p53 gene status

    International Nuclear Information System (INIS)

    We can easily understand that radiation sensitivities of cancer cells are dependent on the status of cancer-related genes. It is important to clarify which genes affect radiation sensitivity and reflect the effectiveness of radiation therapy for cancer cells. We have studied about the function of a tumor suppressor gene of p53, because p53 controls apoptosis, cell cycle and DNA repair from an aspect of important roles in cell fate. By analysis of function of p53 gene, therefore, we aim to predict the therapeutic effectiveness and to select the modalities of cancer therapies such as radiotherapy, chemotherapy and hyperthermia. As a final goal, we want to accept the most effective therapy, namely tailor-made cancer therapy, for each patient. Here, we introduce that carbon-beam therapy induced the expression of p53-independent apoptosis-related genes and NO radicals in mutated p53 cancer cells. (author)

  14. A twelve month study of PM2.5 and PM10 fine particle aerosol composition in the Sydney region using ion beam analysis techniques. Appendix 2

    International Nuclear Information System (INIS)

    The accelerator based ion beam (IBA) analysis techniques of PIXE, PIGME, PESA, and RBS have been used to characterise fine particles at selected sites in the Sydney region. The four techniques operating simultaneously provide elemental concentrations on 24 chemical species, including H, Q N, 0, F, Na, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Cu, Ni, Zn, Br and Pb. The total mass and the elemental carbon by laser integrated plate techniques were also measured. A stacked filter system, built by the University of Gent, Belgium and supplied by the IAEA was used to provide fine particle data on PM2.5 and PM10 particles. While a cyclone sampler, built at ANSTO, Lucas Heights, was used to provide data on PM2.5 particles only. The two different types of units were operated along side each other for the whole of 1994 and the results compared. The use of the multi-elemental IBA techniques also allowed for some fine particle source fingerprinting to be performed. (author)

  15. Alanine-EPR dosimetry in 10 MeV electron beam to optimize process parameters for food irradiation

    International Nuclear Information System (INIS)

    Absorbed dose in a food product is determined and controlled by several components of the LINAC irradiation facility as well as the product. Standardization of the parameters characterizing the facility components, process load and the irradiation conditions collectively termed as 'process parameters' are of paramount importance for successful dose delivery to the food products. In the present study alanine-EPR dosimetry system was employed to optimize the process parameters of 10 MeV electron beam of a LINAC facility for commercial irradiation of food. Three sets of experiments were carried out with different food commodities namely, mango, potato and rawa with the available product conveying system of different irradiation geometry like one sided or both sided mode of irradiation. Three dimensional dose distributions into the process load for low dose requiring food commodities (0.25 to 1 kGy) were measured in each experiment. The actual depth dose profile in food product and useful scan width of the electron beam were found out to be satisfactory for commercial radiation processing of food. Finally a scaled up experiment with commercial food product (packets of Rawa) exhibited adequate dose uniformity ratio of 3 proving the feasibility of the facility for large scale radiation processing of food commodities. (author)

  16. Radiosensitivity and Induction of Apoptosis by High LET Carbon Ion Beam and Low LET Gamma Radiation: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Atanu Ghorai

    2014-01-01

    Full Text Available Cancer treatment with high LET heavy ion beam, especially, carbon ion beam (12C, is becoming very popular over conventional radiotherapy like low LET gamma or X-ray. Combination of Poly(ADP-ribose polymerase (PARP inhibitor with xenotoxic drugs or conventional radiation (gamma or X-ray is the newer approach for cancer therapy. The aim of our study was to compare the radiosensitivity and induction of apoptosis by high LET 12C and low LET gamma radiation in HeLa and PARP-1 knocked down cells. We did comet assay to detect DNA breaks, clonogenic survival assay, and cell cycle analysis to measure recovery after DNA damage. We measured apoptotic parameters like nuclear fragmentation and caspase-3 activation. DNA damage, cell killing, and induction of apoptosis were significantly higher for 12C than gamma radiation in HeLa. Cell killing and apoptosis were further elevated upon knocking down of PARP-1. Both 12C and gamma induced G2/M arrest although the 12C had greater effect. Unlike the gamma, 12C irradiation affects DNA replication as detected by S-phase delay in cell cycle analysis. So, we conclude that high LET 12C has greater potential over low LET gamma radiation in killing cells and radiosensitization upon PARP-1 inhibition was several folds greater for 12C than gamma.

  17. The use of multi-gap resistive plate chambers for in-beam PET in proton and carbon ion therapy

    CERN Document Server

    Watts, David; Sauli, Fabio; Amaldi, Ugo

    2013-01-01

    On-line verification of the delivered dose during proton and carbon ion radiotherapy is currently a very desirable goal for quality assurance of hadron therapy treatment plans. In-beam positron emission tomography (ibPET), which can provide an image of the β+ activity induced in the patient during irradiation, which in turn is correlated to the range of the ion beam, is one of the modalities for achieving this goal. Application to hadron therapy requires that the scanner geometry be modified from that which is used in nuclear medicine. In particular, PET detectors that allow a sub-nanosecond time-of-flight (TOF) registration of the collinear photons have been proposed. Inclusion of the TOF information in PET data leads to more effective PET sensitivity. Considering the challenges inherent in the ibPET technique, namely limited β+ activity and the effect of biological washout due to blood flow, TOF-PET technologies are very attractive. In this context, the TERA Foundation is investigating the use of resistiv...

  18. Fabrication and characterization of tunnel barriers in a multi-walled carbon nanotube formed by argon atom beam irradiation

    International Nuclear Information System (INIS)

    We have evaluated tunnel barriers formed in multi-walled carbon nanotubes (MWNTs) by an Ar atom beam irradiation method and applied the technique to fabricate coupled double quantum dots. The two-terminal resistance of the individual MWNTs was increased owing to local damage caused by the Ar beam irradiation. The temperature dependence of the current through a single barrier suggested two different contributions to its Arrhenius plot, i.e., formed by direct tunneling through the barrier and by thermal activation over the barrier. The height of the formed barriers was estimated. The fabrication technique was used to produce coupled double quantum dots with serially formed triple barriers on a MWNT. The current measured at 1.5 K as a function of two side-gate voltages resulted in a honeycomb-like charge stability diagram, which confirmed the formation of the double dots. The characteristic parameters of the double quantum dots were calculated, and the feasibility of the technique is discussed

  19. Optical diagnostic suite (schlieren, interferometry, and grid image refractometry) on OMEGA EP using a 10-ps, 263-nm probe beam

    International Nuclear Information System (INIS)

    A 10-ps, 263-nm (4ω) laser is being built to probe plasmas produced on the OMEGA EP [J. H. Kelly, L. J. Waxer, V. Bagnoud, I. A. Begishev, J. Bromage, B. E. Kruschwitz, T. E. Kessler, S. J. Loucks, D. N. Maywar, R. L. McCrory et al., J. Phys. IV France 133, 75–80 (2006)]. A suite of optical diagnostics (schlieren, interferometry, and grid image refractometry) has been designed to diagnose and characterize a wide variety of plasmas. Light scattered by the probe beam is collected by an f/4 catadioptric telescope and a transport system is designed to image with a near-diffraction-limited resolution (∼1 −μm full width at half maximum) over a 5-mm field of view to a diagnostic table. The transport system provides a contrast greater than 1 : 104 with respect to all wavelengths outside of the 263 ± 2 nm measurement range.

  20. Effects of E-Beam Irradiation on the Chemical, Physical, and Electrochemical Properties of Activated Carbons for Electric Double-Layer Capacitors

    Directory of Open Access Journals (Sweden)

    Min-Jung Jung

    2015-01-01

    Full Text Available Activated carbons (ACs were modified via e-beam irradiation at various doses for use as an electrode material in electric double-layer capacitors (EDLCs. The chemical compositions of the AC surfaces were largely unchanged by the e-beam irradiation. The ACs treated with the e-beam at radiation doses of 200 kGy exhibited higher nanocrystallinity than the untreated ACs. The specific surface areas and pore volumes of the e-beam irradiated ACs were also higher than those of the untreated ACs. These results were attributed to the transformation and degradation of the nanocrystallinity of the AC surfaces due to the e-beam irradiation. The specific capacitance of the ACs treated with the e-beam at radiation doses of 200 kGy increased by 24% compared with the untreated ACs, and the charge transfer resistance of the ACs was decreased by the e-beam irradiation. The enhancement of the electrochemical properties of the e-beam irradiated ACs can be attributed to an increase in their specific surface area and surface crystallinity.

  1. Design and characterization of a multi-beam micro-CT scanner based on carbon nanotube field emission x-ray technology

    Science.gov (United States)

    Peng, Rui

    In this dissertation, I will present the results for my Ph.D. research for the past five years. My project mainly focuses on advanced imaging applications with a multi-beam x-ray source array based on carbon nanotube field emission technology. In the past few years, research in carbon nanotubes gradually changed from the raw material science to its application. Field emission x-ray application is one of the hottest research areas for carbon nanotube. Compared to traditional thermionic x-ray sources, the carbon nanotube field emission x-ray source has some natural advantages over traditional thermionic x-ray sources such as instantaneous x-ray generation, programmability and miniaturization. For the past few years, the research and development of carbon nanotube field emission x-ray has shifted from single x-ray beam applications to spatially distributed multi-beam x-ray sources. Previously in Zhou group, we have already built a gated micro-CT system with single beam micro-focus x-ray tube for higher spatial and temporal resolution as required in live animal imaging and a multi-beam tomosynthesis system targeting for faster and more stable breast imaging. Now my project mainly focused on the design, characterization and optimization of a multi-beam micro-CT imaging system. With the increase of gantry rotation speed approaching the mechanical limit, it is getting more and more difficult to further speed up the CT scanning. My new system promises a potential solution for the problem, and it serves as a great test platform for truly stationary micro-CT geometry. The potential capabilities it showed during the characterization and imaging measurements was promising. The dissertation is composed of five chapters. In Chapter 1, I will generally review the physics principles of x-ray generation and interaction with matter. Then the discovery of carbon nanotube and its great potential to serve as an excellent field emission electron source will be introduced in the second

  2. Measurement of neutral current neutral pion production on Carbon in a Few-GeV Neutrino Beam

    OpenAIRE

    Kurimoto, Y

    2009-01-01

    The SciBooNE Collaboration has measured neutral current neutral pion production by the muon neutrino beam at a polystyrene target (C8H8). We obtained (7.7+- 0.5(stat.)+0.4-0.5 (sys.)) x 10^-2 as cross section ratio of the neutral current neutral pion production to total charged current cross section at the mean neutrino energy of 1.16 GeV. This result is consistent with the Monte Carlo prediction based on the Rein-Sehgal model

  3. Single-walled carbon nanotubes and nanocrystalline graphene reduce beam-induced movements in high-resolution electron cryo-microscopy of ice-embedded biological samples

    CERN Document Server

    Rhinow, Daniel; Turchanin, Andrey; Gölzhäuser, Armin; Kühlbrandt, Werner; 10.1063/1.3645010

    2011-01-01

    For single particle electron cryo-microscopy (cryoEM), contrast loss due to beam-induced charging and specimen movement is a serious problem, as the thin films of vitreous ice spanning the holes of a holey carbon film are particularly susceptible to beam-induced movement. We demonstrate that the problem is at least partially solved by carbon nanotechnology. Doping ice-embedded samples with single-walled carbon nanotubes (SWNT) in aqueous suspension or adding nanocrystalline graphene supports, obtained by thermal conversion of cross-linked self-assembled biphenyl precursors, significantly reduces contrast loss in high-resolution cryoEM due to the excellent electrical and mechanical properties of SWNTs and graphene.

  4. Equilibrium thickness of carbon target interacting with nitrogen and neon ion beams

    Science.gov (United States)

    Belkova, Yu. A.; Novikov, N. V.; Teplova, Ya. A.

    2016-04-01

    The method for calculation of the target thickness which is required for the formation of equilibrium charge distribution of ions is proposed. The description of nonequilibrium processes is based on empirical estimations of charge-exchange cross sections, taking the density effect for solids into account. The variation of the average charge and the width of the nonequilibrium charge distribution as a function of the target thickness is analyzed. The results of calculations for nitrogen and neon ions in carbon are compared with experimental data.

  5. Megavoltage photon beam attenuation by carbon fiber couch tops and its prediction using correction factors

    International Nuclear Information System (INIS)

    The purpose of this study was to evaluate the effect of megavoltage photon beam attenuation (PBA) by couch tops and to propose a method for correction of PBA. Four series of phantom measurements were carried out. First, PBA by the exact couch top (ECT, Varian) and Imaging Couch Top (ICT, BrainLAB) was evaluated using a water-equivalent phantom. Second, PBA by Type-S system (Med-Tec), ECT and ICT was compared with a spherical phantom. Third, percentage depth dose (PDD) after passing through ICT was measured to compare with control data of PDD. Forth, the gantry angle dependency of PBA by ICT was evaluated. Then, an equation for PBA correction was elaborated and correction factors for PBA at isocenter were obtained. Finally, this method was applied to a patient with hepatoma. PBA of perpendicular beams by ICT was 4.7% on average. With the increase in field size, the measured values became higher. PBA by ICT was greater than that by Type-S system and ECT. PBA increased significantly as the angle of incidence increased, ranging from 4.3% at 180 deg to 11.2% at 120 deg. Calculated doses obtained by the equation and correction factors agreed quite well with the measured doses between 120 deg and 180 deg of angles of incidence. Also in the patient, PBA by ICT was corrected quite well by the equation and correction factors. In conclusion, PBA and its gantry angle dependency by ICT were observed. This simple method using the equation and correction factors appeared useful to correct the isocenter dose when the PBA effect cannot be corrected by a treatment planning system. (author)

  6. Experimental study of proton beam halo in mismatched beams

    International Nuclear Information System (INIS)

    We report measurements of transverse beam-halo formation in mismatched proton beams in a 52-quadrupole FODO-transport channel following the 6.7 MeV RFQ at the Low-Energy Demonstration Accelerator (LEDA) at Los Alamos. Beam profiles in both transverse planes were measured using a new diagnostic device that consists of a movable carbon filament for measurement of the beam core, and scraper plates for measurement of the outer part of the distributions. The initial results indicate a surprisingly strong growth rate of the rms emittance even for the modest space-charge tune depressions of the experiment. Our results are consistent with the complete transfer of free energy of the mismatched beams into emittance growth within 10 envelope oscillations for both the breathing and the quadrupole modes.

  7. Induction of apoptosis in murione spleen lymphocytes using carbon ion beam

    International Nuclear Information System (INIS)

    To assess the capacity of heavy ions to induce apoptosis in lymphocytes, mice have been irradiated with accelerated carbon ions (95 MeV/nucleon) at doses ranging from 0.1 to 4 Gy. Their spleens were removed 24 h later and gently dissociated to prepare a single cell suspension. Mononuclear cells were then maintained in culture at 37oC, and the occurrence of apoptosis in these cells was analysed 24 h later. Lymphocytes were also irradiated in vitro, in the presence of Ac-DEVD-CHO, a potent caspase-3 and -7 inhibitor. Results from three experiments performed at the Grand Accelerateur National d'Ions Lourds (GANIL, Caen, France) are reported here. They indicate that carbon ions induce a marked, dose-dependent, reduction of the spleen weight and cellularity. However, in sharp contrast with spleen cells prepared from X-ray irradiated mice, only a slight increase of apoptosis is evidenced in cultured lymphocytes from mice irradiated with heavy ions. The significance of such results is discussed. So far, few data exist concerning the biological effects of heavy ions, in particular their capacity to induce apoptosis in lymphocytes; the present study provides useful clues for further investigations. (author)

  8. 10 MeV electron beam cross-linking of plasticised PVC in presence of EHPTM and TAC additives

    International Nuclear Information System (INIS)

    Irradiation of plasticised PVC (PPVC) compound containing a cross-linking monomer was carried out by a 10 MeV electron beam. This compound mainly is used as insulation in the wire and cable industry. The cross-linking monomers EHPTM and TAC at different ratio of 3, 6, and 9 phr were used. The dose range was varied from 50 to 150 kGy. The effects of monomers and radiation dose on radiation cross-linking were studied by hot-set testing and gel content measurements. In the absence of EHPTM and TAC, cross-linking did not take place by high energy electron beam at any dose and samples had very large elongation in a hot-set apparatus. But in the presence of these monomers, gel content augmented with an increase in radiation dose and EHPTM level. The highest value of approximately 76% gel content was obtained. In this case the lowest hot-set value was about 12%. Also, tensile strength, elongation at break, modulus, volume resistivity, dielectric strength, and limiting oxygen index of samples were examined. It was found that the mechanical properties of samples containing EHPTM and TAC improved significantly with increasing radiation dose. But for PPVC samples loaded with EHPTM, tensile strength values were higher than those of the loaded ones with TAC at all radiation doses. From the hot-set data it is concluded that the samples loaded with EHPTM had a low thermal expansion compared with samples loaded with TAC. The results indicated that EHPTM is a more effective cross-linking agent for PPVC compound compared with TAC. (authors)

  9. Application of the Ethanol-Chlorobenzene Dosimeter to Electron Beam Dosimetry: Pulsed 10 MeV Electrons

    International Nuclear Information System (INIS)

    With gamma irradiation, the ethanol-chlorobenzene chemical dosimetric systems have shown valuable properties. They are simple to prepare and analyse, the G(HC1) values are not sensitive to normal impurities and are constant within the dose range of interest for processing. This paper describes the experiments performed with 10 MeV pulsed electrons from the linear accelerator of the Research Establishment Risø, Denmark (7 microsecond pulses repeated 300 times per second, 109 rad/sec in the pulse). The irradiations were calibrated calorimetrically. The G(HC1) values independent of dose up to 40 Mrad are given as a function of chlorobenzene concentration. The comparison with gamma irradiations shows only insignificant differences in the G-values. Above 10 vol. % chlorobenzene the G-values are approximately constant up to 20 Mrad or more, and are to within 2% equal to those obtained for gamma rays with free access of air. The addition of 0.04% of acetone or benzene to the systems had within the experimental error, no influence upon the G(HC1). The results show the applicability of ethanol-chlorobenzene dosimeters to the dosimetry of electron beam irradiations at dose rates as high as 109 rad/sec and dosages up to 6 Mrad. (author)

  10. Normal, high and ultra-high modulus carbon fiber-reinforced polymer laminates for bonded and un-bonded strengthening of steel beams

    International Nuclear Information System (INIS)

    Highlights: • Normal, high and ultra-high modulus CFRP laminates for strengthening of steel beams. • Bonded and un-bonded reinforcement systems for steel beams. • Comparisons between the static behavior of the bonded and un-bonded systems. - Abstract: This paper studies the elastic behavior of steel beams strengthened with normal, high and ultra-high modulus CFRP laminates using bonded and un-bonded systems. The elastic behavior of retrofitted beams provides useful information for design of fatigue strengthening systems. A total of seven steel beams including one control unstrengthened beam and six strengthened beams were tested statically until failure in a simply supported four-point bending set-up. The steel beams were retrofitted by normal modulus (NM), high modulus (HM) and ultra-high modulus (UHM) carbon fiber-reinforced polymer (CFRP) laminates with nominal Young’s moduli, ranging from 165 to 440 GPa. Each type of laminate was attached to the steel beams using bonded reinforcement (BR) and un-bonded reinforcement (UR) systems. There is no direct comparison between the BR and the UR systems in the literature. The main goal of the paper is to provide a better understating about the stress distribution along the beam bottom flange when the BR and the UR systems are used for strengthening. All specimens failed due to lateral-torsional buckling (LTB). The effect of different strengthening methods on buckling capacity of the retrofitted specimens was also studied. Experimental results have shown that strengthening using bonded UHM laminates could increase the stiffness of the composite section so that the steel profile has yielded prior to buckling and a larger reinforcement efficacy was then achieved

  11. Including an ocean carbon cycle model into iLOVECLIM (v1.0)

    OpenAIRE

    N. Bouttes; Roche, D. M.; V. Mariotti; L. Bopp

    2015-01-01

    The atmospheric carbon dioxide concentration plays a crucial role in the radiative balance and as such has a strong influence on the evolution of climate. Because of the numerous interactions between climate and the carbon cycle, it is necessary to include a model of the carbon cycle within a climate model to understand and simulate past and future changes of the carbon cycle. In particular, natural variations of atmospheric CO2 have happened in the past, while anthropogenic...

  12. Including an ocean carbon cycle model into iLOVECLIM (v1.0)

    OpenAIRE

    N. Bouttes; Roche, D. M.; V. Mariotti; L. Bopp

    2015-01-01

    The atmospheric carbon dioxide concentration plays a crucial role in the radiative balance and as such has a strong influence on the evolution of climate. Because of the numerous interactions between climate and the carbon cycle, it is necessary to include a model of the carbon cycle within a climate model to understand and simulate past and future changes of the carbon cycle. In particular, natural variations of atmospheric CO2 have happened in the past, while anthropogenic...

  13. Hypofractionated carbon ion therapy delivered with scanned ion beams for patients with hepatocellular carcinoma – feasibility and clinical response

    International Nuclear Information System (INIS)

    Photon-based radiation therapy does currently not play a major role as local ablative treatment for hepatocellular carcinoma (HCC). Carbon ions offer distinct physical and biological advantages. Due to their inverted dose profile and the high local dose deposition within the Bragg peak, precise dose application and sparing of normal tissue is possible. Furthermore, carbon ions have an increased relative biological effectiveness (RBE) compared to photons. A total of six patients with one or more HCC-lesions were treated with carbon ions delivered by the raster-scanning technique according to our clinical trial protocol. Diagnosis of HCC was confirmed by histology or two different imaging modalities (CT and MRI) according to the AASLD-guidelines. Applied fractionation scheme was 4 × 10 Gy(RBE). Correct dose application was controlled by in-vivo PET measurement of β + −activity in the irradiated tissue shortly after treatment. Patients were observed for a median time period of 11.0 months (range, 3.4 – 12.7 months). Imaging studies showed a partial response in 4/7 lesions and a stable disease in 3/7 lesions in follow-up CT- and MRI scans. Local control was 100%. One patient with multifocal intrahepatic disease underwent liver transplantation 3 months after carbon ion therapy. During radiotherapy and the follow-up period no severe adverse events have occurred. We report the first clinical results of patients with HCC undergoing carbon ion therapy using the rasterscanning technique at our institution. All patients are locally controlled and experienced no higher toxicities in a short follow-up period. Further patients will be included in our prospective Phase-I clinical trial PROMETHEUS-01 (NCT01167374)

  14. Homogeneous water nucleation and droplet growth in methane and carbon dioxide mixtures at 235 K and 10 bar.

    Science.gov (United States)

    Holten, V; van Dongen, M E H

    2010-05-28

    Homogeneous nucleation rates and droplet growth rates of water in pure methane and mixtures of methane and carbon dioxide were measured in an expansion wave tube at 235 K and 10 bar. The nucleation rate in pure methane is three orders of magnitude higher than literature nucleation rates of water in low-pressure helium or argon. Addition of carbon dioxide to the carrier gas mixture increases the rates even more. Specifically, rates in a mixture of methane and 3% carbon dioxide are a factor of 10 higher than the rates in pure methane. With 25% carbon dioxide, the rates are four orders of magnitude higher than the rates in pure methane. An application of the nucleation theorem shows that the critical cluster consists of 22 water molecules and 5 methane molecules, for nucleation in pure methane. Growth rates of water droplets were measured in methane and in methane-carbon dioxide mixtures at 243 K and 11.5 bar. At equal temperature, pressure and water vapor fraction, the growth rate of the squared droplet radius is about 20% lower in the mixture with 25% carbon dioxide than in pure methane. The lower growth rate is caused by a smaller diffusion coefficient of water in the mixture with carbon dioxide; the difference of the diffusion coefficients is qualitatively reproduced by the empirical Fuller correlation combined with Blanc's law. PMID:20515097

  15. Effects of a 2-step culture with cytokine combinations on megakaryocytopoiesis and thrombopoiesis from carbon-ion beam-irradiated human hematopoietic stem/progenitor cells

    International Nuclear Information System (INIS)

    To evaluate whether the continuous treatment of two cytokine combinations is effective in megakaryocytopoiesis and thrombopoiesis in hematopoietic stem/progenitor cells exposed to heavy ion beams, the effects of a 2-step culture by a combination of recombinant human interleukin-3 (IL-3)+stem cell factor (SCF)+thrombopoietin (TPO), which just slightly protected against carbon-ion beam-induced damages, and a combination of IL-3+TPO, which selectively stimulated the differentiation of the hematopoietic stem/progenitor cells to megakaryocytes and platelets, were examined. CD34+-hematopoietic stem/progenitor cells isolated from the human placental and umbilical cord blood were exposed to carbon-ion beams (linear energy transfer (LET)=50 keV/μm) at 2 Gy. These cells were cultured under three cytokine conditions. The number of megakaryocytes, platelets and hematopoietic progenitors were assessed using a flow cytometer and a clonogenic assay at 14 and 21 days after irradiation, respectively. However, the efficacy of each 2-step culture was equal or lower than that of using the IL-3+SCF+TPO combination alone and the 2-step culture could not induce megakaryocytes and platelets from hematopoietic stem/progenitor cells exposed to high LET-radiation such as carbon-ion beams. Therefore, additional cytokines and/or hematopoietic promoting compounds might be required to overcome damage to hematopoietic cells by high LET radiation. (author)

  16. Infrared laser spectroscopy of molecular beams

    International Nuclear Information System (INIS)

    Presents the first successful observation of the infrared spectrum of a single, collimated (3.6 x 10-4 steradians) beam of carbon monoxide molecules sampled from a supersonic free jet expansion. The principle of the technique is to detect directly the power absorbed from a tunable infrared laser beam by the molecules of a molecular beam, using a microcalorimeter (a cyrogenic bolometer) placed a short distance downstream from the intersection of the two beams. Since infrared fluorescent lifetimes are long, the absorbed power is transferred by the molecules to the bolometer where it is detected as a change in resistance. (Auth.)

  17. Construction of electron beam machine 350 keV/10 mA for multipurpose application of thin sample at P3TM-BATAN

    International Nuclear Information System (INIS)

    Research and development starting in 1984 of electron beam technology in Indonesia is first briefly presented. BATAN assigned to the Yogyakarta Nuclear Center the project of constructing an electron beam machine of 350 keV/10 mA for multipurpose applications especially for thin samples for duration of five years. The main objective of the project was the young scientists training and demonstration purposes in operation and maintenance of the machine. The engineers have learned through experience of the low energy ion accelerator (150 kV) many techniques to construct the system component such as E-gun, high voltage, vacuum, beam optics, scanning horn and window, beam stopper, and conveyer as well as the embedded control system. Because of the window cooling system, the uses of the machine are limited for irradiating a thin sample of plastics, hydrogel, powder, or liquid. Future plans for modification of the machine are stated. (S. Ohno)

  18. Characterization of ion-beam-induced carbon deposition on WC-Co hard metal by microhardness, scratch and abrasive wear tests

    International Nuclear Information System (INIS)

    Diamond-like ion-beam-deposited carbon (i-C) layers were obtained on WC-Co cemented carbide using a mass-separated 12C beam at an energy of 500 eV and a deposition rate of 3 A s-1. The mechanical properties of these layers were probed using microhardness and scratch tests and abrasive wear measurements. All these tests revealed that the depositions possess an extremely high hardness and good adhesion to the substrate. In particular, a hardness of 75 GPa was obtained, which is considerably higher than that found on i-C films involving hydrogen. (orig.)

  19. Source apportionment of PM10 mass and particulate carbon in the Kathmandu Valley, Nepal

    Science.gov (United States)

    Kim, Bong Mann; Park, Jin-Soo; Kim, Sang-Woo; Kim, Hyunjae; Jeon, Haeun; Cho, Chaeyoon; Kim, Ji-Hyoung; Hong, Seungkyu; Rupakheti, Maheswar; Panday, Arnico K.; Park, Rokjin J.; Hong, Jihyung; Yoon, Soon-Chang

    2015-12-01

    The Kathmandu Valley in Nepal is a bowl-shaped urban basin in the Himalayan foothills with a serious problem of fine particulate air pollution that impacts local health and impairs visibility. Particulate carbon concentrations have reached severe levels that threaten the health of 3.5 million local residents. Moreover, snow and ice on the Himalayan mountains are melting as a result of additional warming due to particulate carbon, especially high black carbon concentrations. To date, the sources of the Valley's particulate carbon and the impacts of different sources on particulate carbon concentrations are not well understood. Thus, before an effective control strategy can be developed, these particulate carbon sources must be identified and quantified. Our study has found that the four primary sources of particulate carbon in the Kathmandu Valley during winter are brick kilns, motor vehicles, fugitive soil dust, and biomass/garbage burning. Their source contributions are quantified using a recently developed new multivariate receptor model SMP. In contrast to other highly polluted areas such as China, secondary contribution is almost negligible in Kathmandu Valley. Brick kilns (40%), motor vehicles (37%) and biomass/garbage burning (22%) have been identified as the major sources of elemental carbon (black carbon) in the Kathmandu Valley during winter, while motor vehicles (47%), biomass/garbage burning (32%), and soil dust (13%) have been identified as the most important sources of organic carbon. Our research indicates that controlling emissions from motor vehicles, brick kilns, biomass/garbage burning, and soil dust is essential for the mitigation of the particulate carbon that threatens public health, impairs visibility, and influences climate warming within and downwind from the Kathmandu Valley. In addition, this paper suggests several useful particulate carbon mitigation methods that can be applied to Kathmandu Valley and other areas in South Asia with

  20. Investigation of Time Effect on Resistivity Variation of 10 MeV Electron Beam Irradiated LDPE and HDPE

    International Nuclear Information System (INIS)

    Charges occur in both the physical and/or chemical nature and concentration of defects in the crystalline region, and traps at chain fold-amorphous interfaces. In this work attempt has bean made to investigate the time effect on the variation of surface and volume resistivity of the LDPE and HDPE samples were irradiated under the 10 MeV electron beam of Rhodotron accelerator. In fact, the aim was to investigate these variations during about one mount after irradiation which is changing due to the charge storage in the polyethylene. The samples were prepared in sheet form with the thickness of 0.6±0.1 mm and irradiated at the dose range of 70 to 370 kGy. All the samples were kept at room temperature in laboratory. The results show an increment at about 25 days after irradiation in surface resistivity and decreasing later on for all the samples. The results of volume resistivity measurements didn't show any significant variation

  1. Test Measurements of a 20 ms-1 Carbon Wire Beam Scanner

    CERN Document Server

    De Freitas, J; Emery, J; Herranz Alvarez, J F; Koujili, M; Ramos, D; Sapinski, M; Ait-Amira, Y; Djerdir, A

    2011-01-01

    This paper pre­sents the de­sign of the ac­tu­a­tor for the fast and high ac­cu­ra­cy Wire Scan­ner sys­tem. The ac­tu­a­tor con­sists of a ro­tary brushless syn­chronous motor with the per­ma­nent mag­net rotor in­stalled in­side the vac­u­um cham­ber and the sta­tor in­stalled out­side. The fork, per­ma­nent mag­net rotor and two an­gu­lar po­si­tion sen­sors are mount­ed on the same axis and lo­cat­ed in­side the beam vac­u­um cham­ber. The system has to re­sist a bake-out tem­per­a­ture of 200 C and ion­iz­ing radi­a­tion up to tenths of kGy/year. Max­i­mum wire trav­el­ling speed of 20 m/s and a po­si­tion mea­sure­ment ac­cu­ra­cy of 4 um is re­quired. Therefore, the sys­tem must avoid gen­er­at­ing vi­bra­tion and electromagnet­ic in­ter­fer­ence. A dig­i­tal feed­back con­troller will allow max­i­mum flex­i­bil­i­ty for the loop pa­ram­e­ters and feeds the 3-phase lin­ear power driv­er. The per­for­mance of the pr...

  2. Nanoimprint of Glass Materials with Glassy Carbon Molds Fabricated by Focused-Ion-Beam Etching

    Science.gov (United States)

    Takahashi, Masaharu; Sugimoto, Kohichi; Maeda, Ryutaro

    2005-07-01

    Micro/nano-imprinting or hot embossing is a target of interest for the industrial production of microdevices. In fluidic micro electromechanical systems (MEMS) applications, polymer materials have been employed for their low cost in the fabrication of economical products. However, glasses are much more suitable for higher-temperature applications or use in reactive chemical environments. In optical MEMS as well, glasses are good candidate materials for enhanced optical properties. In this study, micro/nano-imprinting was employed for Pyrex glass and quartz glass molding, and test structures were successfully fabricated with good fidelity for a 10× 10× 7 μm microstructure and a 0.3 μm line-and-space pattern with a depth of 0.4 μm.

  3. Electron beam generation and structure of defects in carbon and boron nitride nano-tubes

    International Nuclear Information System (INIS)

    The nature and role of defects is of primary importance to understand the physical properties of C and BN (boron nitride) single walled nano-tubes (SWNTs). Transmission electron microscopy (TEM) is a well known powerful tool to study the structure of defects in materials. However, in the case of SWNTs, the electron irradiation of the TEM may knock out atoms. This effect may alter the native structure of the tube, and has also been proposed as a potential tool for nano-engineering of nano-tubular structures. Here we develop a theoretical description of the irradiation mechanism. First, the anisotropy of the emission energy threshold is obtained via density functional based calculations. Then, we numerically derive the total Mott cross section for different emission sites of carbon and boron nitride nano-tubes with different chiralities. Using a dedicated STEM (Scanning Transmission Electron Microscope) microscope with experimental conditions optimised on the basis of derived cross-sections, we are able to control the generation of defects in nano-tubular systems. Either point or line defects can be obtained with a spatial resolution of a few nanometers. The structure, energetics and electronics of point and line defects in BN systems have been investigated. Stability of mono- and di- vacancy defects in hexagonal boron nitride layers is investigated, and their activation energies and reaction paths for diffusion have been derived using the nudged elastic band method (NEB) combined with density functional based techniques. We demonstrate that the appearance of extended linear defects under electron irradiation is more favorable than a random distribution of point defects and this is due to the existence of preferential sites for atom emission in the presence of pre-existing defects, rather than thermal vacancy nucleation and migration. (author)

  4. Electron beam generation and structure of defects in carbon and boron nitride nano-tubes

    Energy Technology Data Exchange (ETDEWEB)

    Zobelli, A

    2007-10-15

    The nature and role of defects is of primary importance to understand the physical properties of C and BN (boron nitride) single walled nano-tubes (SWNTs). Transmission electron microscopy (TEM) is a well known powerful tool to study the structure of defects in materials. However, in the case of SWNTs, the electron irradiation of the TEM may knock out atoms. This effect may alter the native structure of the tube, and has also been proposed as a potential tool for nano-engineering of nano-tubular structures. Here we develop a theoretical description of the irradiation mechanism. First, the anisotropy of the emission energy threshold is obtained via density functional based calculations. Then, we numerically derive the total Mott cross section for different emission sites of carbon and boron nitride nano-tubes with different chiralities. Using a dedicated STEM (Scanning Transmission Electron Microscope) microscope with experimental conditions optimised on the basis of derived cross-sections, we are able to control the generation of defects in nano-tubular systems. Either point or line defects can be obtained with a spatial resolution of a few nanometers. The structure, energetics and electronics of point and line defects in BN systems have been investigated. Stability of mono- and di- vacancy defects in hexagonal boron nitride layers is investigated, and their activation energies and reaction paths for diffusion have been derived using the nudged elastic band method (NEB) combined with density functional based techniques. We demonstrate that the appearance of extended linear defects under electron irradiation is more favorable than a random distribution of point defects and this is due to the existence of preferential sites for atom emission in the presence of pre-existing defects, rather than thermal vacancy nucleation and migration. (author)

  5. Effects of radioprotectors on mutation in cultured mammalian cells by carbon beam

    International Nuclear Information System (INIS)

    The project goal is understand genotoxic effects of high linear energy transfer (LET) radiations, e.g. carbon, 290 MeV/nucleon: LET=100 KeV/μm [C290], and to identify chemicals that can prevent or decrease such pathologies in cultured cells and in exposed humans. We have now quantified effects of C290-induced genotoxicity of several chemicals including WR-1065, cimetidine, lycopene, RibCys [(R, S)-D-ribo(1', 2', 3', 4'-Tetrahydroxybutyl)-thiazolidine-4(R)-ca riboxylic acid, N-acetyl cysteine (NAC), Dimethyl sulfoxide (DMSO) and vitamin C, and combinations of DMSO plus Vitamin C. In vitro, vitamin C showed the most promise. It significantly reduced mutant induction by C290 and also reduced the yield of mutants displaying the cancer-related property of genomic instability even when added after radiation. Unfortunately vitamin C was less effective at doses below 5 mM, which is too high for use in humans. So we are turning to using non-toxic levels of vitamin C in combination with other chemicals. Our recent preliminary results and those of Dr. J. Kumagai indicate that NAC, at doses well tolerated by humans and which scavenge classical hydroxyl radicals, also effectively scavenge mutagenic, long-lived radicals (LLR). We plan, therefore, to evaluate the combined effect of NAC + vitamin C on X-ray mutagenicity (but not initially at Heavy Ion Medical Accelerator in Chiba (HIMAC)). If these experiments look promising we would like to propose experiments with high LET radiation at HIMAC in collaboration with Dr. Kumagai. (author)

  6. The stable carbon isotope composition of PM 2.5 and PM 10 in Mexico City Metropolitan Area air

    Science.gov (United States)

    López-Veneroni, D.

    The sources and distribution of carbon in ambient suspended particles (PM 2.5 and PM 10) of Mexico City Metropolitan Area (MCMA) air were traced using stable carbon isotopes ( 13C/ 12C). Tested potential sources included rural and agricultural soils, gasoline and diesel, liquefied-petroleum gas, volcanic ash, and street dust. The complete combustion of LP gas, diesel and gasoline yielded the lightest δ13C values (-27 to -29‰ vs. PDB), while street dust (PM 10) represented the isotopically heaviest endmember (-17‰). The δ13C values of rural soils from four geographically separated sites were similar (-20.7 ± 1.5‰). δ13C values of particles and soot from diesel and gasoline vehicle emissions and agricultural soils varied between -23 and -26‰. Ambient PM samples collected in November of 2000, and March and December of 2001 at three representative receptor sites of industrial, commercial and residential activities had a δ13C value centered around -25.1‰ in both fractions, resulting from common carbon sources. The predominant carbon sources to MCMA atmospheric particles were hydrocarbon combustion (diesel and/or gasoline) and particles of geological origin. The significantly depleted δ13C values from the industrial site reflect the input of diesel combustion by mobile and point source emissions. Based on stable carbon isotope mass balance, the carbon contribution of geological sources at the commercial and residential sites was approximately 73% for the PM 10 fraction and 54% for PM 2.5. Although not measured in this study, biomass-burning emissions from nearby forests are an important carbon source characterized by isotopically lighter values (-29‰), and can become a significant contributor (67%) of particulate carbon to MCMA air under the prevalence of southwesterly winds. Alternative sources of these 13C-depleted particles, such as cooking fires and municipal waste incineration, need to be assessed. Results show that stable carbon isotope

  7. Beam Simulation Tools for GEANT4 (BT-V1.0). User's Guide

    Energy Technology Data Exchange (ETDEWEB)

    Elvira, V. Daniel [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States). Computational Physics Dept.; Lebrum, P. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States). Computational Physics Dept.; Spentzouris, P. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States). Computational Physics Dept.

    2002-12-02

    Geant4 is a tool kit developed by a collaboration of physicists and computer professionals in the high energy physics field for simulation of the passage of particles through matter. The motivation for the development of the Beam Tools is to extend the Geant4 applications to accelerator physics. The Beam Tools are a set of C++ classes designed to facilitate the simulation of accelerator elements: r.f. cavities, magnets, absorbers, etc. These elements are constructed from Geant4 solid volumes like boxes, tubes, trapezoids, or spheers. There are many computer programs for beam physics simulations, but Geant4 is ideal to model a beam through a material or to integrate a beam line with a complex detector. There are many such examples in the current international High Energy Physics programs. For instance, an essential part of the R&D associated with the Neutrino Source/Muon Collider accelerator is the ionization cooling channel, which is a section of the system aimed to reduce the size of the muon beam in phase space. The ionization cooling technique uses a combination of linacs and light absorbers to reduce the transverse momentum and size of the beam, while keeping the longitudinal momentum constant. The MuCool/MICE (muon cooling) experiments need accurate simulations of the beam transport through the cooling channel in addition to a detailed simulation of the detectors designed to measure the size of the beam. The accuracy of the models for physics processes associated with muon ionization and multiple scattering is critical in this type of applications. Another example is the simulation of the interaction region in future accelerators. The high luminosity and background environments expected in the Next Linear Collider (NLC) and the Very Large Hadron Collider (VLHC) pose great demand on the detectors, which may be optimized by means of a simulation of the detector-accelerator interface.

  8. Protective Sliding Carbon-Based Nanolayers Prepared by Argon or Nitrogen Ion-Beam Assisted Deposition on Ti6Al4V Alloy

    Directory of Open Access Journals (Sweden)

    Petr Vlcak

    2016-01-01

    Full Text Available The microstructure and the surface properties of samples coated by carbon-based nanolayer were investigated in an effort to increase the surface hardness and reduce the coefficient of friction of the Ti6Al4V alloy. Protective carbon-based nanolayers were fabricated by argon or nitrogen ion-beam assisted deposition at ion energy of 700 eV on Ti6Al4V substrates. The Raman spectra indicated that nanolayers had a diamond-like carbon character with sp2 rich bonds. The TiC and TiN compounds formed in the surface area were detected by X-ray diffraction. Nanoscratch tests showed increased adhesion of a carbon-based nanolayer deposited with ion assistance in comparison with a carbon nanolayer deposited without ion assistance. The results showed that argon ion assistance leads to greater nanohardness than a sample coated by a carbon-based nanolayer with nitrogen ion assistance. A more than twofold increase in nanohardness and a more than fivefold decrease in the coefficient of friction were obtained for samples coated by a carbon-based nanolayer with ion assistance, in comparison with the reference sample.

  9. Measurement of analyzing powers of π+ and π- produced on a hydrogen and a carbon target with a 22-GeV/c incident polarized proton beam

    International Nuclear Information System (INIS)

    The analyzing powers of π+ and π- were measured using an incident 22-GeV/c transversely polarized proton beam at the Brookhaven Alternating Gradient Synchrotron. A magnetic spectrometer measured π± inclusive asymmetries on a hydrogen and a carbon target. An elastic polarimeter with a CH2 target measured pp elastic-scattering asymmetries to determine the beam polarization using published data for the pp elastic analyzing power. Using the beam polarization determined from the elastic polarimeter and asymmetries from the inclusive spectrometer, analyzing powers AN for π± were determined in the xF and pT ranges (0.45-0.8) and (0.3-1.2 GeV/c), respectively. The analyzing power results are similar in both sign and character to other measurements at 200 and 11.7 GeV/c, confirming the expectation that high-energy pion inclusive analyzing powers remain large and relatively energy independent. This suggests that pion inclusive polarimetry may be a suitable method for measuring future beam polarizations at BNL RHIC or DESY HERA. Analyzing powers of π+ and π- produced on hydrogen and carbon targets are the same. Various models to explain inclusive analyzing powers are also discussed

  10. Evaluation of nuclear reaction cross-sections and fragment yields in carbon beams using the SHIELD-HIT Monte Carlo code. Comparison with experiments

    International Nuclear Information System (INIS)

    In light ion therapy, the knowledge of the spectra of both primary and secondary particles in the target volume is needed in order to accurately describe the treatment. The transport of ions in matter is complex and comprises both atomic and nuclear processes involving primary and secondary ions produced in the cascade of events. One of the critical issues in the simulation of ion transport is the modeling of inelastic nuclear reaction processes, in which projectile nuclei interact with target nuclei and give rise to nuclear fragments. In the Monte Carlo code SHIELD-HIT, inelastic nuclear reactions are described by the Many Stage Dynamical Model (MSDM), which includes models for the different stages of the interaction process. In this work, the capability of SHIELD-HIT to simulate the nuclear fragmentation of carbon ions in tissue-like materials was studied. The value of the parameter κ, which determines the so-called freeze-out volume in the Fermi break-up stage of the nuclear interaction process, was adjusted in order to achieve better agreement with experimental data. In this paper, results are shown both with the default value κ = 1 and the modified value κ = 10 which resulted in the best overall agreement. Comparisons with published experimental data were made in terms of total and partial charge-changing cross-sections generated by the MSDM, as well as integral and differential fragment yields simulated by SHIELD-HIT in intermediate and thick water targets irradiated with a beam of 400 MeV u−112C ions. Better agreement with the experimental data was in general obtained with the modified parameter value (κ = 10), both on the level of partial charge-changing cross-sections and fragment yields. (paper)

  11. Carbon-ion beams effectively induce growth inhibition and apoptosis in human neural stem cells compared with glioblastoma A172 cells

    International Nuclear Information System (INIS)

    Carbon-ion radiotherapy (CIRT) holds promise in the treatment of glioblastoma, an aggressive X-ray–resistant brain tumor. However, since glioblastoma cells show a highly invasive nature, carbon-ion (C-ion) irradiation of normal tissues surrounding the tumor is inevitable. Recent studies have revealed the existence of neural stem cells in the adult brain. Therefore, the damaging effect of C-ion beams on the neural stem cells has to be carefully considered in the treatment planning of CIRT. Here, we investigated the growth and death mode of human neural stem cells (hNSCs) and glioblastoma A172 cells after X-ray or C-ion beam irradiation. The X-ray dose resulting in a 50% growth rate (D50) was 0.8 Gy in hNSCs and 3.0 Gy in A172 cells, while the D50 for C-ion beams was 0.4 Gy in hNSCs and 1.6 Gy in A172 cells; the relative biological effectiveness value of C-ion beams was 2.0 in hNSCs and 1.9 in A172 cells. Importantly, both X-rays and C-ion beams preferentially induced apoptosis, not necrosis, in hNSCs; however, radiation-induced apoptosis was less evident in A172 cells. The apoptosis-susceptible nature of the irradiated hNSCs was associated with prolonged upregulation of phosphorylated p53, whereas the apoptosis-resistant nature of A172 cells was associated with a high basal level of nuclear factor kappa B expression. Taken together, these data indicate that apoptosis is the major cell death pathway in hNSCs after irradiation. The high sensitivity of hNSCs to C-ion beams underscores the importance of careful target volume delineation in the treatment planning of CIRT for glioblastoma. (author)

  12. An evaluation of the neutron-induced reaction cross sections on carbon from 10 to 20 MeV

    International Nuclear Information System (INIS)

    Available data on the neutron-induced reactions on carbon are reviewed for the energy range from 10 to 20 MeV. Evaluated cross sections obtained at Bruyeres-le-Chatel are discussed. Comparisons with coupled-channel calculations are presented for the total, elastic and inelastic (to the 2+ level) cross sections of 12C

  13. Beam-Beam Effects

    OpenAIRE

    Herr, W; Pieloni, T.

    2016-01-01

    One of the most severe limitations in high-intensity particle colliders is the beam-beam interaction, i.e. the perturbation of the beams as they cross the opposing beams. This introduction to beam-beam effects concentrates on a description of the phenomena that are present in modern colliding beam facilities.

  14. Beam-Beam Effects

    CERN Document Server

    Herr, W

    2014-01-01

    One of the most severe limitations in high-intensity particle colliders is the beam-beam interaction, i.e. the perturbation of the beams as they cross the opposing beams. This introduction to beam-beam effects concentrates on a description of the phenomena that are present in modern colliding beam facilities.

  15. Pore size effects on the sorption of supercritical carbon dioxide in mesoporous CPG-10 silica

    Energy Technology Data Exchange (ETDEWEB)

    Rother, Gernot [ORNL; Krukowski, Elizabeth G [ORNL; Wallacher, Dirk [Helmholtz-Zentrum Berlin; Grimm, Nico [Helmholtz-Zentrum Berlin; Bodnar, Robert J [ORNL; Cole, David [Ohio State University

    2012-01-01

    Excess sorption isotherms of supercritical carbon dioxide in mesoporous CPG-10 silica glasses with nominal pore sizes of 75 (7.5 nm) and 350 (35 nm) were measured gravimetrically at 35 C and 50 C and pressures of 0-200 bar. Formation of broad maxima in the excess sorption was observed at fluid densities below the bulk critical density. Positive values of excess sorption were measured at bulk densities below about 0.65-0.7 g/cm3, whereas zero and negative values were obtained at higher densities, indicating that the interfacial fluid becomes less dense than the corresponding bulk fluid at high fluid densities. A shift of the excess sorption peak position to higher fluid density is found with increasing pore width. The excess sorption of CO2 normalized to the specific surface area is higher for the 35 nm pore size material, suggesting pore confinement effects. Conversely, the pore volume normalized excess sorption is higher for the 7.5 nm pore size material. Assessment of mean pore density reveals regions of constant pore fluid density, located between the excess sorption peak and the adsorption/depletion transition. Both materials exhibit such regions of constant mean pore fluid density as a function of bulk CO2 density at the lower temperature of 35 C, but not at 50 C. The results of this study suggest that the CO2 storage capacity in quartz-rich reservoirs is higher for sites with low temperature and rock textures characterized by narrow pores with high surface to volume ratios.

  16. Structural properties and surface wettability of Cu-containing diamond-like carbon films prepared by a hybrid linear ion beam deposition technique

    International Nuclear Information System (INIS)

    Cu-containing diamond-like carbon (Cu-DLC) films were deposited on Si/glass substrate by a hybrid ion beam deposition system. The Cu concentration (0.1–39.7 at.%) in the film was controlled by varying the sputtering current. The microstructure and composition of Cu-DLC films were investigated systematically. The surface topography, roughness and surface wettability of the films were also studied. Results indicated that with increasing the Cu concentration, the water contact angle of the films changed from 66.8° for pure carbon film to more than 104.4° for Cu-DLC films with Cu concentration larger than 24.4 at.%. In the hydrophilic region, the polar surface energy decreased from 30.54 mJ/m2 for pure carbon film to 2.48 mJ/m2 for the film with Cu 7.0 at.%. - Highlights: • Cu-containing diamond-like carbon (DLC) films were deposited by a hybrid ion beam system. • Cu-containing DLC films exhibited a wide range of water contact angle. • The water contact angles vary with the surface energies and surface roughness

  17. Response of CR39 track etch detector to 10 A GeV Fe 26+ ion beam and total charge changing cross section measurement

    Science.gov (United States)

    Kumar, A.; Gupta, R.; Jalota, S.; Giacomelli, G.; Patrizii, L.; Togo, V.

    2012-01-01

    Total charge changing cross-section of 10 A GeV Fe 26+ ion beam on polyethylene and CR39 targets was measured. Charge of the fragments of projectiles was detected using CR39 nuclear track detectors by a new technique of one-side etching using an automated optical microscope with an image analysing software. The calculated value of total charge changing cross-section is σ tot = (2694 ± 142)mb and is in good agreement with the experimental values by other methods within error. The restricted energy loss ( REL) at energy 10 A GeV for all the fragments was theoretically calculated by using Bethe-Bloch equation and then obtained a calibration curve of reduced etch-rate ratio ( p) versus REL showing the response of CR39 track detectors to 10 A GeV Fe 26+ beam. The curve was fitted by a polynomial showing the relation between p and REL.

  18. Simulation of Neutron Production in Selected Targets by Proton and Deuteron Beam in Energy Range from 10 MeV to 75 MeV

    International Nuclear Information System (INIS)

    Initial inter-comparison study of simulation of neutron production by beam of protons and deuterons in different target materials, in energy range from 10 MeV to 75 MeV, is shown in the paper. An idealised cylindrical (diameter = height = 2.5 cm) target is bombarded, along the central axis, perpendicularly at target base, by an infinite thin particle beam. Simulation is carried out for the target surrounded by void, i.e., the 'return effect' from surrounding materials in a real system is not encountered. The study is carried out using Monte Carlo based computer codes for intermediate and high-energy nucleon transport: LCS, ver.2.7 (LANL, USA) and SHIELD (INR, Russia). Yield (total number of neutrons in 4 , per incident particle) and spectrum of neutrons escaping the target surfaces are determined for different targets made from 208Pb/Pb, 238U/U, 184W/W, Be and 7Li. Maximum neutron yield, near 30%, is calculated for proton beam energy of 75 MeV bombarding 238U/U target, shaped as mentioned above. Generally, neutron yield for deuteron beam is less than neutron yield for proton beam of the same energy for targets made from high-Z nuclides. The opposite conclusion is derived for targets made from low-Z nuclides. (author)

  19. RC beams with steel fibers under impact loads - doi: 10.4025/actascitechnol.v36i1.17561

    Directory of Open Access Journals (Sweden)

    Iana Ingrid Rocha Damasceno

    2014-01-01

    Full Text Available The use of steel fibers as addition improves several mechanical properties of concrete, whose tensile strength and resilience are of great interest for designs of structures subjected to impact loads, such as military facilities, nuclear power plants, bridges and overpasses. However, there are few studies that assessed the effects of adding steel fiber on reinforcements of reinforced concrete. To assess these effects, four concrete beams under impact loads were tested, with reinforcements and different amounts of steel fibers being monitored. The results showed a better performance of beams with fibers, presenting lower strains on reinforcements and cracking.

  20. Measurement of Neutral Current Neutral Pion Production on Carbon in a Few-GeV Neutrino Beam

    Energy Technology Data Exchange (ETDEWEB)

    Kurimoto, Yoshinori [Kyoto Univ. (Japan)

    2010-01-01

    Understanding of the π0 production via neutrino-nucleus neutral current interaction in the neutrino energy region of a few GeV is essential for the neutrino oscillation experiments. In this thesis, we present a study of neutral current π0 production from muon neutrinos scattering on a polystyrene (C8H8) target in the SciBooNE experiment. All neutrino beam data corresponding to 0.99 × 1020 protons on target have been analyzed. We have measured the cross section ratio of the neutral current π0 production to the total charge current interaction and the π0 kinematic distribution such as momentum and direction. We obtain [7.7 ± 0.5(stat.) ± 0.5(sys.)] × 10-2 as the ratio of the neutral current neutral pion production to total charged current cross section; the mean energy of neutrinos producing detected neutral pions is 1.1 GeV. The result agrees with the Rein- Sehgal model, which is generally used for the Monte Carlo simulation by many neutrino oscillation experiments. We achieve less than 10 % uncertainty which is required for the next generation search for νµ → νe oscillation. The spectrum shape of the π0 momentum and the distribution of the π0 emitted angle agree with the prediction, which means that not only the Rein-Sehgal model but also the intra-nuclear interaction models describe our data well. We also measure the ratio of the neutral current coherent pion production to total charged current cross section to be (1.17 ± 0.23 ) × 10-2 based on the Rein and Sehgal model. The result gives the evidence for non-zero coherent pion production via neutral current interaction at the mean neutrino energy of 1.0 GeV.

  1. Improved routines to model the ocean carbonate system: mocsy 1.0

    Directory of Open Access Journals (Sweden)

    J. C. Orr

    2014-05-01

    Full Text Available Software used by modelers to compute ocean carbonate chemistry is often based on code from the Ocean Carbon Cycle Model Intercomparison Project (OCMIP, last revised in 2005. As an update, we offer here new publicly available Fortran 95 routines to model the ocean carbonate system (mocsy. Both codes take as input dissolved inorganic carbon CT and total alkalinity AT, the only two tracers of the ocean carbonate system that are unaffected by changes in temperature and salinity and conservative with respect to mixing, properties that make them ideally suited for ocean carbon models. With the same basic thermodynamic equilibria, both codes compute surface-ocean pCO2 in order to simulate air–sea CO2 fluxes. The mocsy package goes beyond the OCMIP code by computing all other carbonate system variables (e.g., pH, CO32−, and CaCO3 saturation states and by doing so throughout the water column. Moreover, it avoids three common model approximations: that density is constant, that modeled potential temperature is equivalent to in situ temperature, and that depth is equivalent to pressure. These approximations work well at the surface, but total errors in computed variables grow with depth, e.g., reaching −8 μatm in pCO2, +0.010 in pH, and +0.01 in ΩA at 5000 m. Besides the equilibrium constants recommended for best practices, mocsy also offers users three new options: (1 a recent formulation for total boron that increases its ocean content by 4%, (2 an older formulation for KF common to all other such software, and (3 recent formulations for K1 and K2 designed to also include low-salinity waters. More total boron increases borate alkalinity and reduces carbonate alkalinity, which is calculated as a difference from total alkalinity. As a result, the computed surface pCO2 increases by 4 to 6 μatm, while the computed aragonite saturation horizon (ASH shallows by 60 m in the North Atlantic and by up to 90 m in the Southern Ocean. Changes due to the new

  2. TH-E-17A-10: Markerless Lung Tumor Tracking Based On Beams Eye View EPID Images

    Energy Technology Data Exchange (ETDEWEB)

    Chiu, T; Kearney, V; Liu, H; Jiang, L; Foster, R; Mao, W [UT Southwestern Medical Center, Dallas, Texas (United States); Rozario, T; Bereg, S [University of Texas at Dallas, Richardson, Texas (United States); Klash, S [Premier Cancer Centers, Dallas, TX (United States)

    2014-06-15

    Purpose: Dynamic tumor tracking or motion compensation techniques have proposed to modify beam delivery following lung tumor motion on the flight. Conventional treatment plan QA could be performed in advance since every delivery may be different. Markerless lung tumor tracking using beams eye view EPID images provides a best treatment evaluation mechanism. The purpose of this study is to improve the accuracy of the online markerless lung tumor motion tracking method. Methods: The lung tumor could be located on every frame of MV images during radiation therapy treatment by comparing with corresponding digitally reconstructed radiograph (DRR). A kV-MV CT corresponding curve is applied on planning kV CT to generate MV CT images for patients in order to enhance the similarity between DRRs and MV treatment images. This kV-MV CT corresponding curve was obtained by scanning a same CT electron density phantom by a kV CT scanner and MV scanner (Tomotherapy) or MV CBCT. Two sets of MV DRRs were then generated for tumor and anatomy without tumor as the references to tracking the tumor on beams eye view EPID images. Results: Phantom studies were performed on a Varian TrueBeam linac. MV treatment images were acquired continuously during each treatment beam delivery at 12 gantry angles by iTools. Markerless tumor tracking was applied with DRRs generated from simulated MVCT. Tumors were tracked on every frame of images and compared with expected positions based on programed phantom motion. It was found that the average tracking error were 2.3 mm. Conclusion: This algorithm is capable of detecting lung tumors at complicated environment without implanting markers. It should be noted that the CT data has a slice thickness of 3 mm. This shows the statistical accuracy is better than the spatial accuracy. This project has been supported by a Varian Research Grant.

  3. TH-E-17A-10: Markerless Lung Tumor Tracking Based On Beams Eye View EPID Images

    International Nuclear Information System (INIS)

    Purpose: Dynamic tumor tracking or motion compensation techniques have proposed to modify beam delivery following lung tumor motion on the flight. Conventional treatment plan QA could be performed in advance since every delivery may be different. Markerless lung tumor tracking using beams eye view EPID images provides a best treatment evaluation mechanism. The purpose of this study is to improve the accuracy of the online markerless lung tumor motion tracking method. Methods: The lung tumor could be located on every frame of MV images during radiation therapy treatment by comparing with corresponding digitally reconstructed radiograph (DRR). A kV-MV CT corresponding curve is applied on planning kV CT to generate MV CT images for patients in order to enhance the similarity between DRRs and MV treatment images. This kV-MV CT corresponding curve was obtained by scanning a same CT electron density phantom by a kV CT scanner and MV scanner (Tomotherapy) or MV CBCT. Two sets of MV DRRs were then generated for tumor and anatomy without tumor as the references to tracking the tumor on beams eye view EPID images. Results: Phantom studies were performed on a Varian TrueBeam linac. MV treatment images were acquired continuously during each treatment beam delivery at 12 gantry angles by iTools. Markerless tumor tracking was applied with DRRs generated from simulated MVCT. Tumors were tracked on every frame of images and compared with expected positions based on programed phantom motion. It was found that the average tracking error were 2.3 mm. Conclusion: This algorithm is capable of detecting lung tumors at complicated environment without implanting markers. It should be noted that the CT data has a slice thickness of 3 mm. This shows the statistical accuracy is better than the spatial accuracy. This project has been supported by a Varian Research Grant

  4. Fragmentation of 200 and 244 MeV/u carbon beams in thick tissue-like absorbers

    International Nuclear Information System (INIS)

    Stacks consisting of thin CR-39 sheets sandwiched between thick lucite and water absorbers were perpendicularly bombarded by 12C ions at 200 and 244 MeV/u. Track radius distributions representing the charge composition of the fragmented beams were automatically measured by a particle track analysis system. After analysis of the nuclear charge distributions, the total charge removal cross-sections and elemental production cross-sections of fragments with atomic numbers from 5 to 3, were obtained down to the lower energies (∼50 and 100 MeV/u, respectively). It has been found that the measured total charge removal cross-section agrees with theoretical predictions within ∼10% and very well with previous experiments in corresponding energy regions. Two model calculations for production of B fragment are in good agreement with our measured data while a third model overestimates it by ∼12%. Theoretical cross-sections for Be and Li fragments differ strongly among the different models and from measured values

  5. The effects of carbon foil on beams in stripping-accumulation of a heavy-ion synchrotron

    International Nuclear Information System (INIS)

    Stripping-injection scheme is adopted in the synchrotron of an accelerator complex named as HITFiL. HITFIL is dedicated to cancer therapy. High intensity can be reached by using the stripping-injection as the limit of Liouville's theorem is broken due to charge-exchange. But unavoidable traversals of the circulating beams through the foil may cause beam-losses and deteriorations of beam quality, including: 1) beam-losses caused by an alteration of the particles' charge state; 2) emittance growth caused by Multiple Coulomb Scattering; and 3) decrease of mean-momentum and growth of momentum spread induced by energy loss and energy loss straggling. In this paper, the model of particle-foil interaction is established by Monte Carlo processes. The effects of the stripping foil on beams are studied based on an improvement of the ACCSIM code. (authors)

  6. Effect of O2+, H2++ O2+, and N2++ O2+ ion-beam irradiation on the field emission properties of carbon nanotubes

    International Nuclear Information System (INIS)

    The effect of O2+, H2++ O2+, and N2++ O2+ ion-beam irradiation of carbon nanotubes (CNTs) films on the chemical and electronic properties of the material is reported. The CNTs were grown by the chemical vapor deposition technique (CVD) on silicon TiN coated substrates previously decorated with Ni particles. The Ni decoration and TiN coating were successively deposited by ion-beam assisted deposition (IBAD) and afterwards the nanotubes were grown. The whole deposition procedure was performed in situ as well as the study of the effect of ion-beam irradiation on the CNTs by x-ray photoelectron spectroscopy (XPS). Raman scattering, field-effect emission gun scanning electron microscopy (FEG-SEM), and field emission (FE) measurements were performed ex situ. The experimental data show that: (a) the presence of either H2+ or N2+ ions in the irradiation beam determines the oxygen concentration remaining in the samples as well as the studied structural characteristics; (b) due to the experimental conditions used in the study, no morphological changes have been observed after irradiation of the CNTs; (c) the FE experiments indicate that the electron emission from the CNTs follows the Fowler-Nordheim model, and it is dependent on the oxygen concentration remaining in the samples; and (d) in association with FE results, the XPS data suggest that the formation of terminal quinone groups decreases the CNTs work function of the material.

  7. Exhaustive Analysis of a Genotype Space Comprising 10(15 Central Carbon Metabolisms Reveals an Organization Conducive to Metabolic Innovation.

    Directory of Open Access Journals (Sweden)

    Sayed-Rzgar Hosseini

    2015-08-01

    Full Text Available All biological evolution takes place in a space of possible genotypes and their phenotypes. The structure of this space defines the evolutionary potential and limitations of an evolving system. Metabolism is one of the most ancient and fundamental evolving systems, sustaining life by extracting energy from extracellular nutrients. Here we study metabolism's potential for innovation by analyzing an exhaustive genotype-phenotype map for a space of 10(15 metabolisms that encodes all possible subsets of 51 reactions in central carbon metabolism. Using flux balance analysis, we predict the viability of these metabolisms on 10 different carbon sources which give rise to 1024 potential metabolic phenotypes. Although viable metabolisms with any one phenotype comprise a tiny fraction of genotype space, their absolute numbers exceed 10(9 for some phenotypes. Metabolisms with any one phenotype typically form a single network of genotypes that extends far or all the way through metabolic genotype space, where any two genotypes can be reached from each other through a series of single reaction changes. The minimal distance of genotype networks associated with different phenotypes is small, such that one can reach metabolisms with novel phenotypes--viable on new carbon sources--through one or few genotypic changes. Exceptions to these principles exist for those metabolisms whose complexity (number of reactions is close to the minimum needed for viability. Increasing metabolic complexity enhances the potential for both evolutionary conservation and evolutionary innovation.

  8. CRADA Final Report for CRADA Number NFE-10-02991 "Development and Commercialization of Alternative Carbon Precursors and Conversion Technologies"

    Energy Technology Data Exchange (ETDEWEB)

    Norris, Rober [ORNL; Paulauskas, Felix [ORNL; Naskar, Amit [ORNL; Kaufman, Michael [ORNL; Yarborough, Ken [ORNL; Derstine, Chris [The Dow Chemical Company

    2013-10-01

    The overall objective of the collaborative research performed by the Oak Ridge National Laboratory (ORNL) and the Dow Chemical Company under this Cooperative Research And Development Agreement (CRADA NFE-10-02991) was to develop and establish pathways to commercialize new carbon fiber precursor and conversion technology. This technology is to produce alternative polymer fiber precursor formulations as well as scaled energy-efficient advanced conversion technology to enable continuous mode conversion to obtain carbonized fibers that are technically and economically viable in industrial markets such as transportation, wind energy, infrastructure and oil drilling applications. There have been efforts in the past to produce a low cost carbon fiber. These attempts have to be interpreted against the backdrop of the market needs at the time, which were strictly military aircraft and high-end aerospace components. In fact, manufacturing costs have been reduced from those days to current practice, where both process optimization and volume production have enabled carbon fiber to become available at prices below $20/lb. However, the requirements of the lucrative aerospace market limits further price reductions from current practice. This approach is different because specific industrial applications are targeted, most specifically wind turbine blade and light vehicle transportation, where aircraft grade carbon fiber is not required. As a result, researchers are free to adjust both manufacturing process and precursor chemistry to meet the relaxed physical specifications at a lower cost. This report documents the approach and findings of this cooperative research in alternative precursors and advanced conversion for production of cost-effective carbon fiber for energy missions. Due to export control, proprietary restrictions, and CRADA protected data considerations, specific design details and processing parameters are not included in this report.

  9. Diagnostics of electron beam properties from the simultaneous hard X-ray and microwave emission in the 10 March 2001 flare

    CERN Document Server

    Zharkova, V V; Kashapova, L K; Kuznetsov, A A; Altyntsev, A T

    2011-01-01

    Simultaneous simulation of HXR and MW emission with the same populations of electrons is still a great challenge for interpretation of observations in real events. In this paper we apply the FP kinetic model of precipitation of electron beam with energy range from 12 keV to 1.2 MeV to the interpretation of X-ray and microwave emissions observed in the flare of 10 March 2001. Methods. The theoretical HXR and MW emissions were calculated by using the distribution functions of electron beams found by solving time-dependent Fokker-Planck approach in a converging magnetic field (Zharkova at al., 2010; Kuznetsov and Zharkova, 2010) for anisotropic scattering of beam electrons on the ambient particles in Coloumb collisions and Ohmic losses. The simultaneous observed HXR photon spectra and frequency distribution of MW emission and polarization were fit by those simulated from FP models which include the effects of electric field induced by beam electrons and precipitation into a converging magnetic loop. Magnetic fie...

  10. The present status of carbon 14 analysis and projects for beryllium 10 analysis at the Tandetron 1 accelerator, Nagoya University

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Toshio; Oda, Hirotaka; Ikeda, Akiko; Niu, Etsuko [Nagoya Univ. (Japan)

    2001-02-01

    The operation experience in 1999 of the Tandetron accelerator age estimation system, Nagoya University, is reported, after the overview and the history of the accelerator is briefly described. Total number of carbon 14 environmental samples analyzed was 8567. The project of introducing new HVEE Tandetron for C-14 analysis, and modifying the present GIC Tandetron for Be-10 analysis is presented. Ion source shall be replaced, and the heavy ion detector shall be installed. Projected geological and archaeological studies using Be-10 are enumerated. (A. Yamamoto)

  11. RC beams with steel fibers under impact loads - doi: 10.4025/actascitechnol.v36i1.17561

    OpenAIRE

    Iana Ingrid Rocha Damasceno; Muricio de Pina Ferreira; Dênio Ramam Carvalho de Oliveira

    2014-01-01

    The use of steel fibers as addition improves several mechanical properties of concrete, whose tensile strength and resilience are of great interest for designs of structures subjected to impact loads, such as military facilities, nuclear power plants, bridges and overpasses. However, there are few studies that assessed the effects of adding steel fiber on reinforcements of reinforced concrete. To assess these effects, four concrete beams under impact loads were tested, with reinforcements and...

  12. Effects of beam interruption time on tumor control probability in single-fractionated carbon-ion radiotherapy for non-small cell lung cancer

    International Nuclear Information System (INIS)

    Carbon-ion radiotherapy treatment plans are designed on the assumption that the beams are delivered instantaneously, irrespective of actual dose-delivery time structure in a treatment session. As the beam lines are fixed in the vertical and horizontal directions at our facility, beam delivery is interrupted in multi-field treatment due to the necessity of patient repositioning within the fields. Single-fractionated treatment for non-small cell lung cancer (NSCLC) is such a case, in which four treatment fields in multiple directions are delivered in one session with patient repositioning during the session. The purpose of this study was to investigate the effects of the period of dose delivery, including interruptions due to patient repositioning, on tumor control probability (TCP) of NSCLC. All clinical doses were weighted by relative biological effectiveness (RBE) evaluated for instantaneous irradiation. The rate equations defined in the microdosimetric kinetic model (MKM) for primary lesions induced in DNA were applied to the single-fractionated treatment of NSCLC. Treatment plans were made for an NSCLC case for various prescribed doses ranging from 25 to 50 Gy (RBE), on the assumption of instantaneous beam delivery. These plans were recalculated by varying the interruption time τ ranging from 0 to 120 min between the second and third fields for continuous irradiations of 3 min per field based on the MKM. The curative doses that would result in a TCP of 90% were deduced for the respective interruption times. The curative dose was 34.5 Gy (RBE) for instantaneous irradiation and 36.6 Gy (RBE), 39.2 Gy (RBE), 41.2 Gy (RBE), 43.3 Gy (RBE) and 44.4 Gy (RBE) for τ = 0 min, 15 min, 30 min, 60 min and 120 min, respectively. The realistic biological effectiveness of therapeutic carbon-ion beam decreased with increasing interruption time. These data suggest that the curative dose can increase by 20% or more compared to the planned dose if

  13. Effects of beam interruption time on tumor control probability in single-fractionated carbon-ion radiotherapy for non-small cell lung cancer

    Science.gov (United States)

    Inaniwa, T.; Kanematsu, N.; Suzuki, M.; Hawkins, R. B.

    2015-05-01

    Carbon-ion radiotherapy treatment plans are designed on the assumption that the beams are delivered instantaneously, irrespective of actual dose-delivery time structure in a treatment session. As the beam lines are fixed in the vertical and horizontal directions at our facility, beam delivery is interrupted in multi-field treatment due to the necessity of patient repositioning within the fields. Single-fractionated treatment for non-small cell lung cancer (NSCLC) is such a case, in which four treatment fields in multiple directions are delivered in one session with patient repositioning during the session. The purpose of this study was to investigate the effects of the period of dose delivery, including interruptions due to patient repositioning, on tumor control probability (TCP) of NSCLC. All clinical doses were weighted by relative biological effectiveness (RBE) evaluated for instantaneous irradiation. The rate equations defined in the microdosimetric kinetic model (MKM) for primary lesions induced in DNA were applied to the single-fractionated treatment of NSCLC. Treatment plans were made for an NSCLC case for various prescribed doses ranging from 25 to 50 Gy (RBE), on the assumption of instantaneous beam delivery. These plans were recalculated by varying the interruption time τ ranging from 0 to 120 min between the second and third fields for continuous irradiations of 3 min per field based on the MKM. The curative doses that would result in a TCP of 90% were deduced for the respective interruption times. The curative dose was 34.5 Gy (RBE) for instantaneous irradiation and 36.6 Gy (RBE), 39.2 Gy (RBE), 41.2 Gy (RBE), 43.3 Gy (RBE) and 44.4 Gy (RBE) for τ = 0 min, 15 min, 30 min, 60 min and 120 min, respectively. The realistic biological effectiveness of therapeutic carbon-ion beam decreased with increasing interruption time. These data suggest that the curative dose can increase by 20% or more compared to the planned dose if the

  14. Synthesis and biological evaluation of carbon-11 and fluorine-18 labeled tracers for in vivo visualization of PDE10A

    International Nuclear Information System (INIS)

    Introduction: In vivo visualization of PDE10A using PET provides a tool to evaluate the role of PDE10A in various neuropsychiatric diseases and can also be useful in the clinical evaluation of PDE10A inhibitor drug candidates. We evaluated several carbon-11 and fluorine-18 labeled PDE10A inhibitors as potential PDE10A PET radioligands. Materials and Methods: [11C]MP10, [11C]JNJ42071965 and four other tracers were developed. Their biodistribution was evaluated in rats. Rat plasma and brain radiometabolites were quantified. Baseline microPET imaging was performed in normal rats and PDE10A knockout (KO) and wild-type (WT) mice. Blocking and displacement studies were conducted. The selectivity of the tracer binding was further studied in an ex vivo autoradiography experiment in PDE10A KO and WT mice. Results: Biodistribution showed brain uptake for all tracers in the striatum and wash-out from the cerebellum. [11C]1 (11C-MP10) had the highest specific uptake index (striatum (S) vs. cerebellum (C) ratios (S/C)-1) at 60 min (7.4). [11C]5 ([11C]JNJ42071965) had a high index at the early time points (1.0 and 3.7 at 2 and 30 min p.i., respectively). The affinity of [11C]4, [18 F]3 and [18 F]6 was too low to visualize PDE10A using microPET. [11C] 2 showed a specific binding, while kinetics of [11C]1 were too slow. [11C]5 reached equilibrium after 10 min (uptake index = 1.2). Blocking and displacement experiments in rats and baseline imaging in PDE10A KO mice showed specific and reversible binding of [11C]5 to PDE10A. Conclusions: We successfully radiolabeled and evaluated six radiotracers for their potential to visualize PDE10A in vivo. While [11C]1 had the highest striatal specific uptake index, its slow kinetics likely compromise clinical use of this tracer. [11C]5 has a relatively high striatum-to-background ratio and fast kinetic profile, which makes it a valuable carbon-11 alternative

  15. Measurement of fragment production DDX of 72 and 144 MeV 12C beam induced reaction on carbon using Bragg Curve Counter

    International Nuclear Information System (INIS)

    Double differential cross section (DDX) data of fragment production for 72 (6 MeV/nucleon) and 144 MeV (12 MeV/nucleon) 12C beam induced reaction on carbon were measured using a Bragg Curve Counter (BCC). The DDX data were obtained for fragments of He, Li, Be, B, C, N and O at 30 degree emission angle. Theoretical calculation using PHITS code with QMD+GEM model represents the DDX well except for components from reactions of direct process and α particle clustering process. (author)

  16. Quasi first-principles Monte Carlo modeling of energy dissipation by low-energy electron beams in multi-walled carbon nanotube materials

    OpenAIRE

    Emfietzoglou, Dimitris; Kyriakou, Ioanna; Garcia-Molina, Rafael; Abril, Isabel; Kostarelos, Kostas

    2012-01-01

    The energy dissipation pattern of low-energy electron beams (0.3–30 keV) in multi-walled carbon nanotube (MWCNT) materials is studied by Monte Carlo simulation taking into account secondary-electron cascade generation. A quasi first-principles discrete-energy-loss model deduced from a dielectric response function description of electronic excitations in MWCNTs is employed whereby both single-particle and plasmon excitations are included in a unified and self-consistent manner. Our simulations...

  17. Properties of carbon beams for radiotherapy with three different energies: 135 MeV/u, 290 MeV/u and 400 MeV/u

    International Nuclear Information System (INIS)

    Sets of plastic nuclear track detectors, used as spectrometers of linear energy transfer (LET), were exposed to carbon beams at 3 different initial energy levels (135, 290, and 400 MeV/u) obtained from the HIMAC accelerator (NIRS, Chiba, Japan). The detectors were positioned behind PMMA filters of different thickness chosen so as to cover whole area of the Bragg curve. The LET spectra were measured and the dependences of the absorbed dose and other biological weighted factors on the depth were estimated. (orig.)

  18. Using spatial reliability in the probabilistic study of concrete structures: The example of a reinforced concrete beam subjected to carbonation inducing corrosion

    Energy Technology Data Exchange (ETDEWEB)

    Defaux, G.; Pendola, M. [PHIMECA Engineering, 1 allee Alan Turing, 63170 Aubiere (France); Sudret, B. [EDF R and D, Department of Materials and Mechanics of Components, Site des Renardieres, 77818 Moret-sur-Loing Cedex (France)

    2006-07-01

    Several methods, simple or more sophisticated, are tested to determine useful information for reliability problems involving spatial variability. The methods are developed around a simple example of a reinforced concrete beam subjected to carbonation inducing corrosion. A point-in-space reliability analysis is conducted to estimate a first indicator on the length to be replaced. Then, random field are introduced and are taken into account in the reliability problem using simulations methods to determine the empirical cumulative density function (CDF) of the length to be repaired and its moments. Finally, analytical formulations are used to estimate the same moments but with small computational effort. (authors)

  19. Using spatial reliability in the probabilistic study of concrete structures: The example of a reinforced concrete beam subjected to carbonation inducing corrosion

    International Nuclear Information System (INIS)

    Several methods, simple or more sophisticated, are tested to determine useful information for reliability problems involving spatial variability. The methods are developed around a simple example of a reinforced concrete beam subjected to carbonation inducing corrosion. A point-in-space reliability analysis is conducted to estimate a first indicator on the length to be replaced. Then, random field are introduced and are taken into account in the reliability problem using simulations methods to determine the empirical cumulative density function (CDF) of the length to be repaired and its moments. Finally, analytical formulations are used to estimate the same moments but with small computational effort. (authors)

  20. Energy loss of 10 MeV/amu atomic helium in carbon

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, H.; Sakamoto, N. [Nara Women`s Univ. (Japan). Dept. of Physics; Katayama, I. [Institute for Nuclear Study, University of Tokyo, Tanashi, Tokyo 188 (Japan); Haruyama, Y.; Saito, M. [Laboratory of Applied Physics, Kyoto Prefectural University, Kyoto 606 (Japan); Yoshida, K. [Department of Nuclear Engineering, Kyoto University, Kyoto 606-01 (Japan); Tosaki, M. [Radio Isotope Research Center, Kyoto University, Kyoto 606 (Japan); Susuki, Y.; Kimura, K. [Department of Engineering Physics and Mechanics, Kyoto University, Kyoto 606-01 (Japan)

    1997-10-01

    Mean energy losses of 31.8 MeV neutral {sup 3}He atoms penetrating through thin carbon foils of 1.6-7.2 {mu}g/cm{sup 2} were measured using a high-resolution magnetic spectrograph. The measured particles are those entered into the carbon foil as {sup 3}He{sup 0} and emerged from it as {sup 3}He{sup 0}. From the attenuation measurement of {sup 3}He{sup 0} in the foils, we can regard the measured energy losses as those of {sup 3}He{sup 0} in a frozen charge state. The measured stopping power of carbon for 31.8 MeV {sup 3}He{sup 0} is 58.2 {+-} 4.9 eV/{mu}g/cm{sup 2}. Including our previous data for other partially clothed ions of the same velocity, the projectile atomic number dependence of the screening effect due to the bound electrons is roughly reproduced by the theoretical predictions based on the Born approximation. (orig.). 14 refs.

  1. Development of a monoenergetic 1-10 keV neutral lithium beam for the diagnostic of edge plasmas in magnetic confinement devices

    International Nuclear Information System (INIS)

    Diagnostic of plasmas confined by magnetic fields for fusion research based on neutral lithium beam (NLB) is presently considered to be one of the most appropriate methods to carry out the important measurements of edge density and its fluctuation profiles without plasma perturbation. In this CRP project we proposed the development of an NLB source with 1-10 KeV based on a traditional β-eucryptite surface emission source coupled to a Pierce gun geometry accelerator and subsequent neutralization of the Li+ beam by a Li-oven neutralizer. Possible application of such an NLB probe in a medium term (2-3 years) in our country would be in a small RFP in operation and in a low-aspect-ratio tokamak in construction both at LAP/INPE and in other hot plasma devices operating at brazilian universities of Sao Paulo (USP) and Campinas (UNICAMP) with whom we maintain strong collaboration efforts in plasma research. (author). 8 refs

  2. Electroporative interleukin-10 gene transfer ameliorates carbon tetrachloride-induced murine liver fibrosis by MMP and TIMP modulation

    Institute of Scientific and Technical Information of China (English)

    Wen-ying CHOU; Cheng-nan LU; Tsung-hsing LEE; Chia-ling WU; Kung-sheng HUNG; Allan M CONCEJERO; Bruno JAWAN; Cheng-haung WANG

    2006-01-01

    Aim:Liver fibrosis represents a process of healing and scarring in response to chronic liver injury.Effective therapies for liver fibrosis are lacking.Interleukin-10 (IL-10) is a cytokine that downregulates pro-inflammatory responses and has a modulatory effect on hepatic fibrogenesis.The aim of this study was to investigate whether electroporative IL-10 gene therapy has an hepatic fibrolytic effect on mice.Methods:Hepatic fibrosis was induced by administering carbon tetrachloride (CCl4) for 10 weeks in mice.The human IL-10 expression plasmid was delivered via electroporation after hepatic fibrosis was established.Histopathology,reverse transcription polymerase chain reaction (RT-PCR) ,immunoblotting,and gelatin zymography were used to investigate the possible mechanisms of action of IL-10.Results:Human IL-10 gene therapy reversed CCl4-induced liver fibrosis in mice.RT-PCR revealed that IL-10 gene therapy attenuated liver TGF-β1,collagen αl,fibronectin,and cell adhesion molecule mRNA upregulation.Following gene transfer,both the activation of α-smooth muscle actin and cyclooxygenase-2 were significantly attenuated.Furthermore.IL-10 significantly inhibited matrix metalloproteinase-2 (MMP-2) and tissue inhibitors of matrix metalloproteinase (TIMP) activation after CCl4 intoxication.Conclusions:We demonstrated that IL-10 gene therapy attenuated CCl4-induced liver fibrosis in mice.IL-10 prevented upregulated fibrogenic and pro-inflammatory gene responses.Its collagenolytic effect may be attributed to MMP and TIMP modulation.IL-10 gene therapy may be an effective therapeutic modality against liver fibrosis with potential clinical use.

  3. Voltammetric Detection of Diquat at the Carbon Paste Electrode Containing a Ca10(PO46(OH2

    Directory of Open Access Journals (Sweden)

    Moulay Abderrahim EL MHAMMEDI

    2007-01-01

    Full Text Available We report a sensitive electrochemical voltammetric method for analyzing diquat (DQ ions using a carbon paste electrochemical (CPE modified by porous material, such as hydroxyapatite (HAP. Diquat strongly adsorbed on a HAP-CPE surface and provides facile electrochemical quantitative methods for electroactive DQ ions. Operational parameters have been optimized, and the stripping voltammetric performance has been studied using square wave voltammetry. The peaks current intensity are highly linear over the 7×10-7–3×10-4 mol L-1 diquat range examined (10-min accumulation time, with a good sensitivity. These findings can lead to a widespread use of electrochemical sensors to detect DQ contaminates.Scanning electron microscopy was used for morphology observation and in particular the X-ray diffraction analysis (XRD and Fourier transformed infrared spectroscopy (FTIR analysis for characterization of synthesis powder.

  4. Development of digital reconstructed radiography software at new treatment facility for carbon-ion beam scanning of National Institute of Radiological Sciences

    International Nuclear Information System (INIS)

    To increase the accuracy of carbon ion beam scanning therapy, we have developed a graphical user interface-based digitally-reconstructed radiograph (DRR) software system for use in routine clinical practice at our center. The DRR software is used in particular scenarios in the new treatment facility to achieve the same level of geometrical accuracy at the treatment as at the imaging session. DRR calculation is implemented simply as the summation of CT image voxel values along the X-ray projection ray. Since we implemented graphics processing unit-based computation, the DRR images are calculated with a speed sufficient for the particular clinical practice requirements. Since high spatial resolution flat panel detector (FPD) images should be registered to the reference DRR images in patient setup process in any scenarios, the DRR images also needs higher spatial resolution close to that of FPD images. To overcome the limitation of the CT spatial resolution imposed by the CT voxel size, we applied image processing to improve the calculated DRR spatial resolution. The DRR software introduced here enabled patient positioning with sufficient accuracy for the implementation of carbon-ion beam scanning therapy at our center.

  5. D-methionine as a protector for heavy ion radiation-induced oral mucositis. Evaluation of RBE of carbon-ion beams for epithelial thickness on mouse tongues

    International Nuclear Information System (INIS)

    To evaluate if D-methionine, the dextro-isomer of the common amino acid L-methionine, can prevent oral mucositis resulting from heavy ion irradiation during treatment for head and neck cancers. For the first study, relative biological effectiveness (RBE) of carbon-ion beams for epithelial thickness on mouse tongues was evaluated. The head of female C3H mice, 8 weeks old, were irradiated by five fractionated doses of carbon ion beams (290 MeV/u) or 150 kV X-rays to induce oral mucositis (ulcers on tongue). Six days after the last irradiation, mice were sacrificed. Excised tongues were evaluated macroscopically and microscopically. The thickness of the lingual epithelium was measured. The RBE of 6-cm spread-out Bragg peak (SOBP) (290 MeV/u) for epithelium on mouse tongues after fractionated doses is 1.82. It was almost the equivalent value as that for gut crypt survivals reported by enormous studies. (author)

  6. Measurements of Dose-Averaged Linear Energy Transfer Distributions in Water Using CR-39 Plastic Nuclear Track Detector for Therapeutic Carbon Ion Beams

    Science.gov (United States)

    Kohno, Ryosuke; Yasuda, Nakahiro; Takeshi, Himukai; Kase, Yuki; Ochiai, Keiko; Komori, Masataka; Matsufuji, Naruhiro; Kanai, Tatsuaki

    2005-12-01

    A CR-39 plastic nuclear track detector was used as a linear energy transfer (LET) detector for carbon ion radiotherapy. We compared dose-averaged LET distributions in water obtained using the CR-39 detector for a monoenergetic beam and spread-out Bragg peak beam by calculations using the one-dimensional heavy-ion transport code used in the current heavy-ion treatment planning. We confirmed that the CR-39 detector could measure the high LET particles that are dominant contributors to dose-averaged LET. On the other hand, the CR-39 result was overestimated in the tail region of the distal edge in depth-dose distributions, due to its detection limit for lower LET particles. However, physical dose in the region is quite small. Namely, the effect of this difference on the biological dose distribution is also small. These results demonstrate that the CR-39 detector is a useful detector for measuring the LET distribution in carbon ion radiotherapy.

  7. Stability analysis of carbon nanotubes based on a novel beam model and Its comparison with Sanders Shell Model and molecular dynamics simulations

    International Nuclear Information System (INIS)

    We study the effects of small-scale parameter on the buckling loads and strains of nanobeams, based on nonlocal Timoshenko beam model. However, the lack of higher order boundary conditions leads to inconsistencies in critical buckling loads. In this paper, we apply a novel approach based on nonlocal Timoshenko kinematics, strain gradient approach and variational methods for deriving all classical and higher-order boundary conditions as well as governing equations. Therefore, closed-form and exact critical buckling loads of nanobeams with various end conditions are investigated. Moreover, the dependence of buckling loads on the small-scale parameter as well as shear deformation coefficient is studied using these new boundary conditions. Then, numerical results from this new beam model are presented for carbon nanotubes (CNTs). They illustrate a more accurate buckling response as compared to the previous works. Furthermore, the critical strains are compared with results obtained from molecular dynamic simulations as well as Sanders shell theory and are found to be in good agreement. Results show that unlike the other beam theories, this model can capture correctly the small-scale effects on buckling strains of short CNTs for the shell-type buckling. Moreover, the value of nonlocal constant is calculated for CNTs using molecular dynamic simulation results. (author)

  8. An integrated Dissolved Organic Carbon Dynamics Model (DOCDM 1.0): model development and a case study in the Alaskan Yukon River Basin

    OpenAIRE

    Lu, X.; Zhuang, Q.

    2015-01-01

    Quantitative understanding of the variation in dissolved organic carbon (DOC) is important to studying the terrestrial ecosystem carbon cycle. This study presents a process-based, dissolved organic carbon dynamics model (DOCDM 1.0) that couples the soil heat conduction, water flow, DOC production, mineralization and transport in both surface and subsurface of soil profile to quantify DOC dynamics in boreal terrestrial ecosystems. The model...

  9. Improved recovery demonstration for Williston Basin carbonates. Annual report, June 10, 1995--June 9, 1996

    Energy Technology Data Exchange (ETDEWEB)

    Carrell, L.A.; Sippel, M.A.

    1996-09-01

    The purpose of this project is to demonstrate targeted infill and extension drilling opportunities, better determinations of oil-in-place, methods for improved completion efficiency and the suitability of waterflooding in Red River and Ratcliffe shallow-shelf carbonate reservoirs in the Williston Basin, Montana, North Dakota and South Dakota. Improved reservoir characterization utilizing three-dimensional and multi-component seismic are being investigated for identification of structural and stratigraphic reservoir compartments. These seismic characterization tools are integrated with geological and engineering studies. Improved completion efficiency is being tested with extended-reach jetting lance and other ultra-short-radius lateral technologies. Improved completion efficiency, additional wells at closer spacing and better estimates of oil in place will result in additional oil recovery by primary and enhanced recovery processes.

  10. The Bonding of NO2, NH3, and CH2NY to Models of a (10,0) Carbon Nanotube

    Science.gov (United States)

    Walch, Stephen P.

    2004-01-01

    We have studied the bonding of NO2, NH3, and CH2NH to a (10,O) carbon nanotube using the MP2 and ONIOM methods with extended basis sets. We find bond strengths of 3.5, 3.6. and 6.3 kcal/mol for NO2, NH3, and CH2NH, respectively, using the ONIOM method with the high accuracy part treated at the MP2/aug-CC-pVTZ level and the remainder of the CNT approximated at the UFF level and including an estimate of basis set superposition error using the counterpoise method.

  11. High-Temperature Interaction Between Molten AlSr10 Alloy and Glass-Like Carbon Substrate

    Science.gov (United States)

    Siewiorek, A.; Sobczak, N.; Sobczak, J.; Kudyba, A.; Kozera, R.; Boczkowska, A.

    2016-03-01

    Wettability of glass-like carbon substrate (Cglc) by molten Al-10 wt.% Sr alloy (AlSr10) has been examined by a sessile drop method at 700-800 °C for 120 min under vacuum. Non-contact heating to the test temperature combined with the removal of oxide film from the alloy drop was done using capillary purification procedure by squeezing the liquid alloy from a capillary. The influence of the type of capillary on wetting behavior of AlSr10/Cglc couples was noticed. Molten AlSr10 alloy does not wet Cglc at about 700 °C forming the contact angles of 111° with graphite capillary and 141° with alumina capillary. At 800 °C with alumina capillary, non-wetting-to-wetting transition takes place resulting in a final contact angle of 70°. After testing at 800 °C, the AlSr10/Cglc interface was revealed at the test temperature directly in the vacuum chamber by the drop suction procedure. Structural characterization of the interfaces by scanning and transmission electron microscopy combined with energy-dispersive x-ray spectroscopy and by scanning probe microscopy combined with Auger electron spectrometry did not show any new phases formed with Sr. It suggests that the dominant role in wettability improvement by alloying Al with 10 wt.% Sr was related with significant lowering of the surface tension of liquid metal and adsorption of Sr at the interface.

  12. Organic and elemental carbon associated to PM10 and PM 2.5 at urban sites of northern Greece.

    Science.gov (United States)

    Samara, Constantini; Voutsa, Dimitra; Kouras, Athanasios; Eleftheriadis, Kostas; Maggos, Thomas; Saraga, D; Petrakakis, M

    2014-02-01

    Organic carbon (OC) and elemental carbon (EC) concentrations, associated to PM10 and PM2.5 particle fractions, were concurrently determined during the warm and the cold months of the year (July-September 2011 and February-April 2012, respectively) at two urban sites in the city of Thessaloniki, northern Greece, an urban-traffic site (UT) and an urban-background site (UB). Concentrations at the UT site (11.3 ± 5.0 and 8.44 ± 4.08 14 μg m(-3) for OC10 and OC2.5 vs. 6.56 ± 2.14 and 5.29 ± 1.54 μg m(-3) for EC10 and EC2.5) were among the highest values reported for urban sites in European cities. Significantly lower concentrations were found at the UB site for both carbonaceous species, particularly for EC (6.62 ± 4.59 and 5.72 ± 4.36 μg m(-3) for OC10 and OC2.5 vs. 0.93 ± 0.61 and 0.69 ± 0.39 μg m(-3) for EC10 and EC2.5). Despite that, a negative UT-UB increment was frequently evidenced for OC2.5 and PM2.5 in the cold months possibly indicative of emissions from residential wood burning at the urban-background site. At both sites, cconcentrations of OC fractions were significantly higher in the cold months; on the contrary, EC fractions at the UT site were prominent in the warm season suggesting some influence from maritime emissions in the nearby harbor area. Secondary organic carbon, being estimated using the EC tracer method and seasonally minimum OC/EC ratios, was found to be an appreciable component of particle mass particularly in the cold season. The calculated secondary contributions to OC ranged between 35 and 59 % in the PM10 fraction, with relatively higher values in the PM2.5 fraction (39-61 %). The source origin of carbonaceous species was investigated by means of air parcel back trajectories, satellite fire maps, and concentration roses. A local origin was mainly concluded for OC and EC with limited possibility for long range transport of biomass (agricultural waste) burning aerosol. PMID:23979848

  13. Three-dimensional thermal simulations of thin solid carbon foils for charge stripping of high current uranium ion beams at a proposed new heavy-ion linac at GSI

    Science.gov (United States)

    Tahir, N. A.; Kim, V.; Schlitt, B.; Barth, W.; Groening, L.; Lomonosov, I. V.; Piriz, A. R.; Stöhlker, Th.; Vormann, H.

    2014-04-01

    This paper presents an extensive numerical study of heating of thin solid carbon foils by 1.4 MeV/u uranium ion beams to explore the possibility of using such a target as a charge stripper at the proposed new Gesellschaft für Schwerionenforschung high energy heavy-ion linac. These simulations have been carried out using a sophisticated 3D computer code that accounts for physical phenomena that are important in this problem. A variety of beam and target parameters have been considered. The results suggest that within the considered parameter range, the target will be severely damaged by the beam. Thus, a carbon foil stripper does not seem to be a reliable option for the future Gesellschaft für Schwerionenforschung high energy heavy-ion linac, in particular, at FAIR design beam intensities.

  14. Atomic oxygen beam source for erosion simulation

    Science.gov (United States)

    Cuthbertson, J. W.; Langer, W. D.; Motley, R. W.

    1990-01-01

    A device for production of low-energy (5-10 eV) neutral atomic beams for surface modification studies, which recreates the flux of atomic oxygen in LEO, is described. The beam is produced by acceleration of plasma ions onto a negatively biased plate of high-Z metal; the ions are neutralized and reflected by the surface, retaining a large fraction of their incident kinetic energy, forming a beam of atoms. The device is based on a magnetically confined (3-4 kG) coaxial plasma source and the atom energy can be varied by adjusting the bias voltage. The source provides a neutral flux of roughly 5 x 10 to the 16th/sq cm/s at a distance of 10 cm and a fluence of roughly 10 to the 21st/sq cm in five hours. The source has been characterized with plasma diagnostics and by measuring the energy of an atomic argon beam using a mass spectrometer. Samples of carbon film, carbon-based paint, Kapton, Mylar, and Teflon exposed to atomic O beams show erosion quite similar to those observed in orbit on the Space Shuttle.

  15. 10 CFR 30.21 - Radioactive drug: Capsules containing carbon-14 urea for “in vivo” diagnostic use for humans.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Radioactive drug: Capsules containing carbon-14 urea for...: Capsules containing carbon-14 urea for “in vivo” diagnostic use for humans. (a) Except as provided in...-14 urea (allowing for nominal variation that may occur during the manufacturing process) each,...

  16. Three ways to solve the orbit of KIC 11 558 725: a 10-day beaming sdB+WD binary with a pulsating subdwarf

    Science.gov (United States)

    Telting, J. H.; Østensen, R. H.; Baran, A. S.; Bloemen, S.; Reed, M. D.; Oreiro, R.; Farris, L.; Ottosen, T. A.; Aerts, C.; Kawaler, S. D.; Heber, U.; Prins, S.; Green, E. M.; Kalomeni, B.; O'Toole, S. J.; Mullally, F.; Sanderfer, D. T.; Smith, J. C.; Kjeldsen, H.

    2012-08-01

    The recently discovered subdwarf B (sdB) pulsator KIC 11 558 725 is one of the 16 pulsating sdB stars detected in the Kepler field. It features a rich g-mode frequency spectrum, with a few low-amplitude p-modes at short periods. This makes it a promising target for a seismic study aiming to constrain the internal structure of this star, and of sdB stars ingeneral. We have obtained ground-based spectroscopic radial-velocity measurements of KIC 11 558 725 based on low-resolution spectra in the Balmer-line region, spanning the 2010 and 2011 observing seasons. From these data we have discovered that KIC 11 558 725 is a binary with period P = 10.05 d, and that the radial-velocity amplitude of the sdB star is 58 km s-1. Consequently the companion of the sdB star has a minimum mass of 0.63 M⊙, and is therefore most likely an unseen white dwarf. We analyse the near-continuous 2010-2011 Kepler light curve to reveal the orbital Doppler-beaming effect, giving rise to light variations at the 238 ppm level, which is consistent with the observed spectroscopic orbital radial-velocity amplitude of the subdwarf. We use the strongest 70 pulsation frequencies in the Kepler light curve of the subdwarf as clocks to derive a third consistent measurement of the orbital radial-velocity amplitude, from the orbital light-travel delay. The orbital radius asdBsini = 11.5 R⊙ gives rise to a light-travel time delay of 53.6 s, which causes aliasing and lowers the amplitudes of the shortest pulsation frequencies, unless the effect is corrected for. We use our high signal-to-noise average spectra to study the atmospheric parameters of the sdB star, deriving Teff = 27 910 K andlog g = 5.41 dex, and find that carbon, nitrogen and oxygen are underabundant relative to the solar mixture. Furthermore, we analyse the Kepler light curve for its pulsational content and extract more than 160 significant frequencies.We investigate the pulsation frequencies for expected period spacings and rotational

  17. Carbon concentrations of components of trees in 10-year-old Populus davidiana stands within the Desertification Combating Program of Northern China

    Science.gov (United States)

    Shen, Huitao; Zhang, Wanjun; Cao, Jiansheng; Zhang, Xiang; Xu, Quanhong; Yang, Xue; Xiao, Dengpan; Zhao, Yanxia

    2016-03-01

    Most studies do not consider the potential variation in carbon concentration among the different tree components of the same species in regional scale. This study examined the carbon concentrations of the components (i.e., foliage, branch, stem, and root) in a 10-year-old poplar species (Populus davidiana Dode) from the Desertification Combating Program of Northern China. The highest and lowest carbon concentrations were found in the stem and foliage, respectively. There was a significant difference in carbon concentrations among the different tree components. All of the observed carbon concentrations of tree components were lower than those predicted using the conversion factor of 0.5 applied to component biomass. Stem carbon made up 59.7% of the total tree biomass carbon. The power equation estimating proportion of tree biomass carbon against the independent variable of diameter at breast height explained more than 90% of the variability in allocation of carbon among tree components. Tree height, as a second independent variable is also discussed. Our results suggest that the difference in organic carbon concentration among tree components should be incorporated into accurately develop forest carbon budget. Moreover, further investigations on how the diameter at breast height equation developed in the present study performs across broader scales are required.

  18. MODIFICATION OF CARBON STEEL BY LASER SURFACE MELTING: PART II: EFFECT OF LASER BEAM POWER ON MICROSTRUCTURAL FEATURES AND SURFACE HARDNESS

    Directory of Open Access Journals (Sweden)

    Hashem F. El-Labban

    2013-01-01

    Full Text Available The surface hardness has an important effect on the wear resistance of different materials. The present study aims to improve the surface hardness of carbon steel through the application of laser surface melting with suitable conditions. The laser beam power and travelling speed are the main factors that affect the properties of the treated zone. In this study, three different conditions of laser beam power (1800, 1500 and 1200 W at fixed travelling speed of 1000 mm min-1 were chosen to study the effect of laser beam power. The resulted laser treated specimens were investigated in macro and microscopically scale using optical and scanning electron microscope. Hardness measurements were also carried out through the thickness of the laser treated zones. The laser treated areas with all used powers results in melted and solidified zone on the surface of the steel. The laser power of 1800 W results in the deepest value of the laser treated zone (about 1.7 mm. Moreover, by increasing the laser power, the width of the treated zone was slightly increases. At areas near the free surface, large martensite plates were observed in higher laser power (1800 W, while longer acicular martensite was observed in lower laser power (1200 W. For laser power of 1800 W, the bainite structures in ferrite grains were more pronounced in larger areas and in closer areas to the free surface. On the other hand, the lower laser power shows higher hardness on the free surface than that of higher power. The sizes of Heat Affect Zone (HAZ areas were increased by increasing the laser beam power. In all conditions, the heat affected zone areas were composed of partially decomposed pearlite in ferrite grains.

  19. Electron-Beam Irradiation Effect on Thermal and Mechanical Properties of Nylon-6 Nanocomposite Fibers Infused with Diamond and Diamond Coated Carbon Nanotubes

    Science.gov (United States)

    Imam, Muhammad A.; Jeelani, Shaik; Rangari, Vijaya K.; Gome, Michelle G.; Moura, Esperidiana. A. B.

    2016-02-01

    Nylon-6 is an engineering plastic with excellent properties and processability, which are essential in several industrial applications. The addition of filler such as diamond (DN) and diamond coated carbon nanotubes (CNTs) to form molded composites may increase the range of Nylon-6 applications due to the resulting increase in strength. The effects of electron-beam irradiation on these thermoplastic nanocomposites are either increase in the cross-linking or causes chain scission. In this study, DN-coated CNTs were synthesized using the sonochemical technique in the presence of cationic surfactant cetyltrimethyl ammonium bromide (CTAB). The DN-coated CNTs nanoparticles and diamond nanoparticles were then introduced into Nylon-6 polymer through a melt extrusion process to form nanocomposite fibers. They were further tested for their mechanical (Tensile) and thermal properties (thermogravimetric analysis (TGA), differential scanning calorimetry (DSC)). These composites were further exposed to the electron-beam (160kGy, 132kGy and 99kGy) irradiation using a 1.5MeV electron-beam accelerator, at room temperature, in the presence of air and tested for their thermal and mechanical properties. The best ultimate tensile strength was found to be 690MPa and 864MPa irradiated at 132 for DN/CNTs/Nylon-6 and Diamond/Nylon-6 nanocomposite fiber as compared to 346MPa and 321MPa for DN/CNTs/Nylon-6 and Diamond/Nylon-6 nanocomposite fiber without irradiation. The neat Nylon-6 tensile strength was 240MPa. These results are consistent with the activation energy calculated from TGA graphs. DSC analysis result shows that the slight increase in glass transition temperature (Tg) and decrease in melting temperature (Tm) which was expected from high electron-beam radiation dose.

  20. Beam-beam effects

    Energy Technology Data Exchange (ETDEWEB)

    Zholents, A.

    1994-12-01

    The term beam-beam effects is usually used to designate different phenomena associated with interactions of counter-rotating beams in storage rings. Typically, the authors speak about beam-beam effects when such interactions lead to an increase of the beam core size or to a reduction of the beam lifetime or to a growth of particle`s population in the beam halo and a correspondent increase of the background. Although observations of beam-beam effects are very similar in most storage rings, it is very likely that every particular case is largely unique and machine-dependent. This constitutes one of the problems in studying the beam-beam effects, because the experimental results are often obtained without characterizing a machine at the time of the experiment. Such machine parameters as a dynamic aperture, tune dependencies on amplitude of particle oscillations and energy, betatron phase advance between the interaction points and some others are not well known, thus making later analysis uncertain. The authors begin their discussion with demonstrations that beam-beam effects are closely related to non linear resonances. Then, they will show that a non linearity of the space charge field is responsible for the excitation of these resonances. After that, they will consider how beam-beam effects could be intensified by machine imperfections. Then, they will discuss a leading mechanism for the formation of the beam halo and will describe a new technique for beam tails and lifetime simulations. They will finish with a brief discussion of the coherent beam-beam effects.

  1. Adenovirus-mediated FIR demonstrated TP53-independent cell-killing effect and enhanced antitumor activity of carbon-ion beams.

    Science.gov (United States)

    Kano, M; Matsushita, K; Rahmutulla, B; Yamada, S; Shimada, H; Kubo, S; Hiwasa, T; Matsubara, H; Nomura, F

    2016-01-01

    Combination therapy of carbon-ion beam with the far upstream element-binding protein (FBP)-interacting repressor, FIR, which interferes with DNA damage repair proteins, was proposed as an approach for esophageal cancer treatment with low side effects regardless of TP53 status. In vivo therapeutic antitumor efficacy of replication-defective adenovirus (E1 and E3 deleted adenovirus serotype 5) encoding human FIR cDNA (Ad-FIR) was demonstrated in the tumor xenograft model of human esophageal squamous cancer cells, TE-2. Bleomycin (BLM) is an anticancer agent that introduces DNA breaks. The authors reported that Ad-FIR involved in the BLM-induced DNA damage repair response and thus applicable for other DNA damaging agents. To examine the effect of Ad-FIR on DNA damage repair, BLM, X-ray and carbon-ion irradiation were used as DNA damaging agents. The biological effects of high linear energy transfer (LET) radiotherapy used with carbon-ion irradiation are more expansive than low-LET conventional radiotherapy, such as X-rays or γ rays. High LET radiotherapy is suitable for the local control of tumors because of its high relative biological effectiveness. Ad-FIR enhanced BLM-induced DNA damage indicated by γH2AX in vitro. BLM treatment increased endogenous nuclear FIR expression in TE-2 cells, and P27Kip1 expression was suppressed by TP53 siRNA and BLM treatment. Further, Ad-FIRΔexon2, a dominant-negative form of FIR that lacks exon2 transcriptional repression domain, decreased Ku86 expression. The combination of Ad-FIR and BLM in TP53 siRNA increased DNA damage. Additionally, Ad-FIR showed synergistic cell toxicity with X-ray in vitro and significantly increased the antitumor efficacy of carbon-ion irradiation in the xenograft mouse model of TE-2 cells (P=0.03, Mann-Whitney's U-test) and was synergistic with the sensitization enhancement ratio (SER) value of 1.15. Therefore, Ad-FIR increased the cell-killing activity of the carbon-ion beam that avoids late

  2. Test and Analysis of Tube Component of Electron Beam Machine (EBM) 350 keV/10 m A

    International Nuclear Information System (INIS)

    Tube component is the one of the local component that is designed and constructed using local materials in the Center of Advanced Technology Research and Development, and used mainly for vacuum chamber of EBM vacuum system. Gas load, product gases from out gassing process, permeation, evaporation and leakage, are factors that can affect the vacuum level of the vacuum chamber. By baking out the vacuum chamber, the releasing process from inside and wall surface will be faster, so that the out gassing and permeation rate will increase. By applying baked out process the tube having better vacuum performance were obtained. From the calculation results for the vacuum level chamber having volume of 9,859 liter and surface area of 4004,45 cm2, without baking out the out gassing rate (QD) was 4,644 x 10-6 Torr liter/sec., permeation (QP) was 4,923 x 10-6 Torr liter/sec., leakage (QL) was 1,691 x 10-9 Torr liter/sec, gas load (QG) was 9,568 x 10-6 Torr liter/sec. By baking out at 104,3 oC we obtained (QD) 2,276 x 10-5 Torr liter/sec, (QP) 1,831 x 10-5 Torr liter/sec, (QL) 3,161 x 10-9 Torr liter/sec, and (QG) 4,108 x 10-5 Torr liter/sec. The experimental results indicated that the final vacuum level which can be obtained the tube component without baking out was 3.375 x 10-6 Torr in 5.33 hours, and with baking out at 104,3 oC the vacuum level was 2,25 x 10-6 Torr in 4,25 hours. Whereas the experimental results of vacuum components in EBM system to be obtained the vacuum were 3,1 x 10-6 mbar (2,33.10-6 Torr). Those result indicated that the tube components fulfill the requirement to be used for the vacuum chamber component in the vacuum system of EBM. (author)

  3. Flying wire beam profile monitor at the J-PARC MR

    International Nuclear Information System (INIS)

    A flying wire beam profile monitor has been assembled and installed at the main ring of the Japan Proton Accelerator Research Complex. The monitor is to measure the horizontal beam profile using a carbon fiber of 7 μmφ. The fiber crosses the beam with the speed of 10 m/s. Secondary particles from the beam-wire scattering is detected using a scintillation counter. The scintillator signal as a function of the wire position is to be reconstructed as a beam profile. The high scanning speed and the minimum material are necessary for the accurate beam profile measurement. The monitor has been operated in the beam commissioning run of the main ring. The beam profile data have been successfully acquired after the reduction of the beam background. (author)

  4. Output factor comparison of Monte Carlo and measurement for Varian TrueBeam 6 MV and 10 MV flattening filter-free stereotactic radiosurgery system.

    Science.gov (United States)

    Cheng, Jason Y; Ning, Holly; Arora, Barbara C; Zhuge, Ying; Miller, Robert W

    2016-01-01

    The dose measurements of the small field sizes, such as conical collimators used in stereotactic radiosurgery (SRS), are a significant challenge due to many factors including source occlusion, detector size limitation, and lack of lateral electronic equilibrium. One useful tool in dealing with the small field effect is Monte Carlo (MC) simulation. In this study, we report a comparison of Monte Carlo simulations and measurements of output factors for the Varian SRS system with conical collimators for energies of 6 MV flattening filter-free (6 MV) and 10 MV flattening filter-free (10 MV) on the TrueBeam accelerator. Monte Carlo simulations of Varian's SRS system for 6 MV and 10 MV photon energies with cones sizes of 17.5 mm, 15.0 mm, 12.5 mm, 10.0 mm, 7.5 mm, 5.0 mm, and 4.0 mm were performed using EGSnrc (release V4 2.4.0) codes. Varian's version-2 phase-space files for 6 MV and 10 MV of TrueBeam accelerator were utilized in the Monte Carlo simulations. Two small diode detectors Edge (Sun Nuclear) and Small Field Detector (SFD) (IBA Dosimetry) were applied to measure the output factors. Significant errors may result if detector correction factors are not applied to small field dosimetric measurements. Although it lacked the machine-specific kfclin,fmsrQclin,Qmsr correction factors for diode detectors in this study, correction factors were applied utilizing published studies conducted under similar conditions. For cone diameters greater than or equal to 12.5 mm, the differences between output factors for the Edge detector, SFD detector, and MC simulations are within 3.0% for both energies. For cone diameters below 12.5 mm, output factors differences exhibit greater variations. PMID:27167266

  5. One-nucleon transfer reactions induced by secondary beam of 11Be: study of the nuclear structure of the exotic nuclei 11Be and 10Li

    International Nuclear Information System (INIS)

    The structure of the neutron rich light nuclei 11Be and 10Li has been investigated by means of one nucleon transfer reactions. The experiments have been carried out at GANIL in inverse kinematics using 11Be secondary beams. The 11Be(p,d)10Be reaction bas been studied at 35.3 MeV/u. The 10Be ejectiles were analyzed by the spectrometer SPEG, and coincident deuterons were detected in the position sensitive silicon detector CHARISSA. Transfer cross sections to 0+1 and 2+1, states in 10Be were measured up to θCM = 16 deg. and compared to DWBA and CRC predictions. The effects of neutron-cure couplings on reaction form factors have been studied by solving coupled equations in the framework of a vibrational model. It is shown that the rate of core excitation 10Be2+ in the 11Begs wave function is overestimated by a standard analysis with form factors given by the usual Separation Energy prescription. The former model predicts a rate of core excitation of 16% and leads to theoretical cross sections which are in good agreement with the experimental data. The aim of the 11Be(d,3He)10Li experiment, realized at 37 MeV/u, was to measure the distribution of the 2s neutron strength in the unbound nucleus 10Li. The energy spectrum was deduced from the 3He energy and angle measured by the silicon strip detector array MUST. An asymmetric peak is clearly observed near the threshold, with a maximum at -Sn = 130 keV. This constitutes a direct proof of the inversion of 2s and 1p1/2 shells in 10Li, which was until now a controversial question in spite of many experimental efforts. On the other band the analysis of the 11Be(d,t)10Be reaction studied in the same experiment confirms the results obtained in the 11Be(p,d)10Be reaction concerning the 11Begs structure. This work shows the interest and feasibility of studies of the shell properties of exotic nuclei using transfer reactions induced by radioactive beams and constitutes the beginning of a program devoted to this kind of experiment

  6. Synergistic effect of heat shock protein 90 inhibitor, 17-allylamino-17-demethoxygeldanamycin and X-rays, but not carbon-ion beams, on lethality in human oral squamous cell carcinoma cells

    International Nuclear Information System (INIS)

    The purpose of this study is to clarify the effect of a heat shock protein 90 inhibitor, 17-allylamino-17-demethoxygeldanamycin (17-AAG), in combination with X-rays or carbon-ion beams on cell killing in human oral squamous cell carcinoma LMF4 cells. Cell survival was measured by colony formation assay. Cell-cycle distribution was analyzed by flow cytometry. Expression of DNA repair-related proteins was investigated by western blotting. The results showed 17-AAG to have synergistic effects on cell lethality with X-rays, but not with carbon-ion beams. The 17-AAG decreased G2/M arrest induced by X-rays, but not by carbon-ion beams. Both X-ray and carbon-ion irradiation up-regulated expression of non-homologous end-joining-associated proteins, Ku70 and Ku80, but 17-AAG inhibited only X-ray-induced up-regulation of these proteins. These results show that 17-AAG with X-rays releases G2/M phase arrest; cells carrying misrepaired DNA damage then move on to the G1 phase. We demonstrate, for the first time, that the radiosensitization effect of 17-AAG is not seen with carbon-ion beams because 17-AAG does not affect these changes. (author)

  7. Increased strength characteristics of low carbon micro-alloyed steel grade 10g2fb

    OpenAIRE

    Nosenko, O. P.

    2016-01-01

    Aim. The purpose of research is the search of new technological methods of increasing mechanical and performance properties of the steel grade 10G2FB for metal structures of responsible appointment. Methods. The structure of the steel samples wasstudied by qualitative and quantitative light microscopy at microscopes "Epikvant", "Neofot-2". Testing mechanical properties of tensile was carried out according to DSTU EN 10002 1:. 2006, toughness was determined on a U- and V-notch samples for Stat...

  8. Direct formation of thin films and epitaxial overlayers at low temperatures using a low-energy (10-500 eV) ion beam deposition system

    International Nuclear Information System (INIS)

    A low-energy ion beam deposition system has been developed at Oak Ridge National Laboratory and has been applied successfully to the growth of epitaxial films at low temperatures for a number of different elements. The deposition system utilizes the ion source and optics of a commercial ion implantation accelerator. The 35 keV mass- and energy-analyzed ion beam from the accelerator is decelerated in a four-element electrostatic lens assembly to energies between 10 and 500 eV for direct deposition onto a target under UHV conditions. Current densities on the order of 10 μA/cm2 are achieved with good uniformity over a 1.4 cm diameter spot. The completed films are characterized by Rutherford backscattering, ion channeling, cross-section transmission electron microscopy, and x-ray diffraction. The effects of substrate temperature, ion energy, and substrate cleaning have been studied. Epitaxial overlayers which show good minimum yields by ion channeling (3 to 4%) have been produced at temperatures as low as 3750C for Si on Si(100) and 2500C for Ge on Ge(100) at growth rates that exceed the solid-phase epitaxy rates at these temperatures by more than an order of magnitude

  9. External beam and HDR intracavitary irradiation: an effective tool in the primary treatment of cervical cancer - excellent 10 year results and low side effects

    International Nuclear Information System (INIS)

    Introduction: The purpose of this paper is to present our 15 years experience in the primary treatment of cervical cancer with a combination of external beam irradiation and high dose rate brachytherapy. Survival data will be presented and the safe use of intrauterine HDR applications will be demonstrated. Material and Methods: From August 1980 to December 1990, 303 patients with cancer of the uterine cervix underwent primary irradiation in a combination of external beam and HDR intracavitary treatment at the Department of Radiation Oncology at the Sisters of Mercy Hospital in Linz, Austria. All patients were classified according to the FIGO rules: Stage I 54 patients, stage II 171, stage III 75 and stage IV 3 patients. 8 patients were lost to follow up. The mean follow up time of survivors is 110 months. Results and Discussion: A complete remission could be achieved in 282 patients, which is 93%; persistent tumour was found in 21 patients at the first follow up check 3 to 5 months after completion of irradiation. The actuarial overall survival probability for all patients at 5 and 10 years is 62 % and 42 % respectively, the disease specific survival probability is 68 % and 64 %. The local control rate at 5 and 10 years is 73 % and 72 % respectively. According to stage, disease specific survival lies at 90 % for stage I, 69 % for stage II, and 48 % for stage III and IV at 5 years, and at 10 years 87 %, 66 % and 41 % respectively. The actuarial local control probability for stages I, II, and III/IV is 90 %, 74 %, and 60 % respectively at 5 yr, and 88 %, 74 %, and 56 % at 10 yr. (Kaplan-Meier calculations). From all 303 patients 34 suffered from 40 severe and moderate side effects (glossary of Chassagne and Sismondi). The rate for grade II complications is 10 % and for grade III 3 %. Conclusion: Intrauterine HDR brachycurietherapy in addition to external beam irradiation for primary treatment of invasive carcinoma of the uterine cervix provides the same treatment

  10. The T10 beam produces a few hits per event. In ALICE the SSD will have to cope with many hits per strip. In the three centimeters of aluminium the beam will produce many secondary particles. This increases the chance of multiple hits per strip, although not to the level in ALICE.

    CERN Multimedia

    Nooren, G.

    2004-01-01

    The T10 beam produces a few hits per event. In ALICE the SSD will have to cope with many hits per strip. In the three centimeters of aluminium the beam will produce many secondary particles. This increases the chance of multiple hits per strip, although not to the level in ALICE.

  11. Nuclear fragmentation of high-energy light-ion beams in water

    International Nuclear Information System (INIS)

    Light-ion beams ranging between carbon and neon with energies of a few hundred MeV/u offer favorable conditions for the treatment of deep-seated tumors. Nuclear fragmentation experiments are presented to study favorable therapy beams simultaneously in thick water target. Comparative measurements with 10B, 12C, 14N, 16O beams are described. (R.P.) 5 refs.; 4 figs

  12. The beam energy calibration system for the BEPC-II collider

    CERN Document Server

    Achasov, M N; Mo, Xiaohu; Muchnoi, N Yu; Qin, Qing; Qu, Huamin; Wang, Yifang; Xu, Jinqiang

    2008-01-01

    This document contains a proposal of the BEPC-II collider beam energy calibration system (IHEP, Beijing). The system is based on Compton backscattering of carbon dioxide laser radiation, producing a beam of high energy photons. Their energy spectrum is then accurately measured by HPGe detector. The high-energy spectrum edge will allow to determine the average electron or positron beam energy with relative accuracy about 3x10^-5.

  13. Elemental and organic carbon in PM10: a one year measurement campaign within the European Monitoring and Evaluation Programme EMEP

    Directory of Open Access Journals (Sweden)

    W. Maenhaut

    2007-03-01

    Full Text Available In the present study, ambient aerosol (PM10 concentrations of elemental carbon (EC, organic carbon (OC, and total carbon (TC are reported for 12 European rural background sites and two urban background sites following a one-year (1 July 2002–1 July 2003 sampling campaign within the European Monitoring and Evaluation Programme, EMEP (http://www.emep.int/. The purpose of the campaign was to assess the feasibility of performing EC and OC monitoring on a regular basis and to obtain an overview of the spatial and seasonal variability on a regional scale in Europe. Analyses were performed using the thermal-optical transmission (TOT instrument from Sunset Lab Inc., operating according to a NIOSH derived temperature program. The annual mean mass concentration of EC ranged from 0.17±0.19 μg m−3 (mean ± SD at Birkenes (Norway to 1.83±1.32 μg m−3 at Ispra (Italy. The corresponding range for OC was 1.20±1.29 μg m−3 at Mace Head (Ireland to 7.79±6.80 μg m−3 at Ispra. On average, annual concentrations of EC, OC, and TC were three times higher for rural background sites in Central, Eastern and Southern Europe compared to those situated in the Northern and Western parts of Europe. Wintertime concentrations of EC and OC were higher than those recorded during summer for the majority of the sites. Moderate to high Pearson correlation coefficients (rp (0.50–0.94 were observed for EC versus OC for the sites investigated. The lowest correlation coefficients were noted for the three Scandinavian sites: Aspvreten (SE, Birkenes (NO, and Virolahti (FI, and the Slovakian site Stara Lesna, and are suggested to reflect biogenic sources, wild and prescribed fires. This suggestion is supported by the fact that higher concentrations of OC are observed for summer compared to winter for these sites. For the rural background sites, total carbonaceous material accounted for 30±9% of PM10, of which 27±9% could be attributed to organic matter (OM and 3.4±1.0

  14. Elemental and organic carbon in PM10: a one year measurement campaign within the European Monitoring and Evaluation Programme EMEP

    Directory of Open Access Journals (Sweden)

    W. Maenhaut

    2007-11-01

    Full Text Available In the present study, ambient aerosol (PM10 concentrations of elemental carbon (EC, organic carbon (OC, and total carbon (TC are reported for 12 European rural background sites and two urban background sites following a one-year (1 July 2002–1 July 2003 sampling campaign within the European Monitoring and Evaluation Programme, EMEP http://www.emep.int/. The purpose of the campaign was to assess the feasibility of performing EC and OC monitoring on a regular basis and to obtain an overview of the spatial and seasonal variability on a regional scale in Europe. Analyses were performed using the thermal-optical transmission (TOT instrument from Sunset Lab Inc., operating according to a NIOSH derived temperature program. The annual mean mass concentration of EC ranged from 0.17±0.19 μg m−3 (mean ± SD at Birkenes (Norway to 1.83±1.32 μg m−3 at Ispra (Italy. The corresponding range for OC was 1.20±1.29 μg m−3 at Mace Head (Ireland to 7.79±6.80 μg m−3 at Ispra. On average, annual concentrations of EC, OC, and TC were three times higher for rural background sites in Central, Eastern and Southern Europe compared to those situated in the Northern and Western parts of Europe. Wintertime concentrations of EC and OC were higher than those recorded during summer for the majority of the sites. Moderate to high Pearson correlation coefficients (rp (0.50–0.94 were observed for EC versus OC for the sites investigated. The lowest correlation coefficients were noted for the three Scandinavian sites: Aspvreten (SE, Birkenes (NO, and Virolahti (FI, and the Slovakian site Stara Lesna, and are suggested to reflect biogenic sources, wild and prescribed fires. This suggestion is supported by the fact that higher concentrations of OC are observed for summer compared to winter for these sites. For the rural background sites, total carbonaceous material accounted for 30±9% of PM10, of which 27±9% could be attributed to organic matter (OM and 3.4±1.0

  15. SEM in situ MiniCantilever Beam Bending of U-10Mo/Zr/Al Fuel Elements

    Energy Technology Data Exchange (ETDEWEB)

    Mook, William [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Baldwin, Jon K. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Martinez, Ricardo M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mara, Nathan A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-06-16

    In this work, the fracture behavior of Al/Zr and Zr/dU-10Mo interfaces was measured via the minicantilever bend technique. The energy dissipation rates were found to be approximately 3.7-5 mj/mm2 and 5.9 mj/mm2 for each interface, respectively. It was found that in order to test the Zr/U-10Mo interface, location of the hinge of the cantilever was a key parameter. While this test could be adapted to hot cell use through careful alignment fixturing and measurement of crack lengths with an optical microscope (as opposed to SEM, which was used here out of convenience), machining of the cantilevers via MiniMill in such a way as to locate the interfaces at the cantilever hinge, as well as proper placement of a femtosecond laser notch will continue to be key challenges in a hot cell environment.

  16. Investigations of adsorption states of protium and deuterium in redeposited carbon flakes formed in tokamak T-10

    International Nuclear Information System (INIS)

    This work reports thermal desorption spectroscopy (TDS), Fourier-transform infrared (FT-IR) spectroscopy and X-ray diffraction (XRD) analyses on free standing redeposited hydrocarbon films (flakes) with a high deuterium to hydrogen isotopic ratio, produced in the T-10 tokamak in the Kurchatov Institute. XRD pattern showed that the carbon flakes differ substantially from graphite and are non-crystalline. The TDS D2(H2) curves consist of two groups of peaks (450-800 K and 900-1000 K), and appeared to be rather similar to those obtained for a mechanically milled nanostructured graphite. As a result, two main adsorption states with activation energies of about 0.65 and 1.25 eV/H were found, implying a hopping diffusion and a resonance mechanism, respectively. The IR spectral differences between reddish-gold and dark-brown flakes showed a less degree of C-H hybridization for dark films and a disordered carbon network, to which the CD2,3 end-groups are connected

  17. Under-response of a PTW-60019 microDiamond detector in the Bragg peak of a 62 MeV/n carbon ion beam.

    Science.gov (United States)

    Rossomme, S; Hopfgartner, J; Vynckier, S; Palmans, H

    2016-06-21

    To investigate the linear energy transfer (LET) dependence of the response of a PTW-60019 Freiburg microDiamond detector, its response was compared to the response of a plane-parallel Markus chamber in a 62 MeV/n mono-energetic carbon ion beam. Results obtained with two different experimental setups are in agreement. As recommended by IAEA TRS-398, the response of the Markus chamber was corrected for temperature, pressure, polarity effects and ion recombination. No correction was applied to the response of the microDiamond detector. The ratio of the response of the Markus chamber to the response of the microDiamond is close to unity in the plateau region. In the Bragg peak region, a significant increase of the ratio is observed, which increases to 1.2 in the distal edge region. Results indicate a correlation between the under-response of the microDiamond detector and high LET values. The combined relative standard uncertainty of the results is estimated to be 2.38% in the plateau region and 12% in the distal edge region. These values are dominated by the uncertainty of alignment in the non-uniform beam and the uncertainty of range determination. PMID:27224547

  18. Molecular dynamics simulations of electron and ion beam irradiation of multiwalled carbon nanotubes: The effects on failure by inner tube sliding

    International Nuclear Information System (INIS)

    Irradiation of nanotube structures with electron and ion beams has been used to produce functionalized nanotubes and fundamentally new structures, including junctions. Here, we build on previous studies to investigate the low-energy electron and ion (Ar and CF3) beam irradiation of triple-walled carbon nanotubes that consist entirely of either chiral or armchair tubes. Effective incident energies of 50 eV/ion and 50 keV/electron are considered. The approach is classical molecular dynamic simulations using reactive empirical bond-order potentials and the primary knock-on atom approach to model the effects of electron irradiation. The results indicate that these various irradiation processes produce local damage to the nanotubes that includes crosslinking, that the degree of damage depends to some degree on the chirality of the nanotubes, and that the radial distribution of crosslinks depends significantly on the irradiating particle. Importantly, the effect of these crosslinks, and their radial distribution along the circumference of the nanotube, on the tendency of multiwalled nanotubes to fail by the sword-in-sheath mechanism is examined

  19. Under-response of a PTW-60019 microDiamond detector in the Bragg peak of a 62 MeV/n carbon ion beam

    Science.gov (United States)

    Rossomme, S.; Hopfgartner, J.; Vynckier, S.; Palmans, H.

    2016-06-01

    To investigate the linear energy transfer (LET) dependence of the response of a PTW-60019 Freiburg microDiamond detector, its response was compared to the response of a plane-parallel Markus chamber in a 62 MeV/n mono-energetic carbon ion beam. Results obtained with two different experimental setups are in agreement. As recommended by IAEA TRS-398, the response of the Markus chamber was corrected for temperature, pressure, polarity effects and ion recombination. No correction was applied to the response of the microDiamond detector. The ratio of the response of the Markus chamber to the response of the microDiamond is close to unity in the plateau region. In the Bragg peak region, a significant increase of the ratio is observed, which increases to 1.2 in the distal edge region. Results indicate a correlation between the under-response of the microDiamond detector and high LET values. The combined relative standard uncertainty of the results is estimated to be 2.38% in the plateau region and 12% in the distal edge region. These values are dominated by the uncertainty of alignment in the non-uniform beam and the uncertainty of range determination.

  20. 1 1/2 years of experience with a 10 MeV self-shielded on-line e-beam sterilization system

    International Nuclear Information System (INIS)

    The Vascular Intervening Group of the Guidant Corporation (Guidant IV) has been operating a self-shielded, 10 MeV 4 kW, electron beam sterilization system since July of 1988. The system was designed, built and installed in a 70 square meter area in an existing Guidant manufacturing facility by Titan Scan Corporation and performance of the system was validated in conformance with 1S0-11137 standards. The goal of this on-site e-beam system was 'just in time' JIT, sterilization, i.e. the ability to manufacture, sterilize and ship, high intrinsic value medical devices in less than 24 hours. The benefits of moving from a long gas sterilization cycle of greater than one week to a JIT process were envisioned to be a) speed to market with innovated new products b) rapid response to customer requirements c) reduced inventory carrying costs and finally manufacturing and quality system efficiency. The ability of Guidant to realize these benefits depended upon the ability of the Guidant VI business units to adapt to the new sterilization modality and functionality and on the overall system reliability. This paper reviews the operating experience to date and the overall system reliability. (author)

  1. Fluence-to-effective dose conversion coefficients from a Saudi population based phantom for monoenergetic photon beams from 10 keV to 20 MeV

    International Nuclear Information System (INIS)

    Fluence-to-dose conversion coefficients are important quantities for radiation protection, derived from Monte Carlo simulations of the radiation particles through a stylised phantom or voxel based phantoms. The voxel phantoms have been developed for many ethnic groups for their accurate reflection of the anatomy. In this study, we used the Monte Carlo code MCNPX to calculate the photon fluence-to-effective dose conversion coefficients with a voxel phantom based on the Saudi Arabian male population. Six irradiation geometries, anterior–posterior (AP), posterior–anterior (PA), left lateral (LLAT), right lateral (RLAT), rotational (ROT) and isotropic (ISO) were simulated for monoenergetic photon beams from 10 keV to 20 MeV. We compared the coefficients with the reference values in ICRP Publication 116. The coefficients in the AP and PA geometries match the reference values to 9% and 12% on average as measured by root mean square while those in the LLAT, RLAT ROT and ISO geometries differ, mostly below, from the reference by 23, 22, 15 and 16%, respectively. The torso of the Saudi phantom is wider than the ICRP reference male phantom and likely to cause more attenuation to the lateral beam. The ICRP reference coefficients serve well for the Saudi male population as conservative estimations for the purpose of radiation protection. (paper)

  2. Experimental water content measurements of carbon dioxide in equilibrium with hydrates at (223.15 to 263.15) K and (1.0 to 10.0) MPa

    International Nuclear Information System (INIS)

    Highlights: • Experimental water content data for carbon dioxide in equilibrium with hydrates. • Data required for setting drying requirements in carbon dioxide streams. • Comparison of experimental data with model predictions and available literature data. -- Abstract: The environmental impact of carbon dioxide has led to the need for capture and storage processes. Whenever water is present, at conditions inside the carbon dioxide hydrate stability zone, there is the possibility of hydrate formation which can cause problems such as pipeline restriction and blockage. To avoid such problems it is essential to know how dry the carbon dioxide needs to be. The measurement of the water content of carbon dioxide in equilibrium with hydrates at different temperature and pressure conditions gives a value below which hydrates will not form. There is a scarcity of relevant experimental data especially at low temperatures (<263.15 K). This is in part due to the challenging nature of making accurate equilibrium water content measurements at these conditions. The experimental data can be used to compare with predictions made using different thermodynamic models. This paper presents experimental equipment, methods and results for the water content of carbon dioxide in equilibrium with hydrates at temperatures between (223.15 and 263.15) K and pressures between (1.0 and 10.0) MPa, hence in both vapour and liquid phases. The experimental data are compared with predictions from an in-house (previously developed) thermodynamic model

  3. Risk of simulated microgravity on testicular injury induced by high-LET carbon-ion beams in mice

    International Nuclear Information System (INIS)

    This study investigated the impact of simulated microgravity on acute injury induced by low doses of carbon ions in male reproductive organs of mice, and determined alterations in spermatogenic function and expression levels of apoptotic factors in mice following exposure to acute irradiation after 7 days of simulated microgravity. The results demonstrated that significant reductions in spermatozoa, primary spermatocytes and spermatogonia, and increased globular cells in seminiferous tubule and pro-apoptotic proteins were observed in the group exposed to over 0.4 Gy irradiation. Collectively, the data suggest that lesions inflicted by simulated microgravity are not markedly modified by lower doses of irradiation (0.2 Gy) in mouse testis compared to the control group. However, testicular impairments were markedly evident in the group exposed to higher doses of carbon ions plus simulated microgravity, which may be due at least in part to elevated apoptosis initiated by the mitochondrial apoptosis pathway in germ cells. (authors)

  4. MODIFICATION OF CARBON STEEL BY LASER SURFACE MELTING: PART I: EFFECT OF LASER BEAM TRAVELLING SPEED ON MICROSTRUCTURAL FEATURES AND SURFACE HARDNESS

    Directory of Open Access Journals (Sweden)

    Hashem F. El-Labban

    2013-01-01

    Full Text Available The present study aims to improve the surface hardness of carbon steel by application of laser surface melting of effective conditions. The travelling speed of laser beam during this treatment is one of the important treatment conditions. This study aims to investigate the effect of laser surface melting with different beam speeds on macro and microstructure as well as the hardness distribution through the thickness of carbon steel. To achieve this target, three different travelling speeds (1500, 1000 and 500 mm min-1 at a constant beam power of 800 W were chosen in this study. The resulted laser treated specimens were investigated in macro and microscopically scale using optical and scanning electron microscope. Hardness measurements were also carried out through the thickness of the laser treated specimens. The laser treated areas with all used travelling speeds results in melted and solidified zone on the surface of the steel. In the same time, Plates of acicular martensite structure were observed within the upper part of the melted and solidified zone in almost all experimental conditions, while some bainite structure in ferrite grains are detected in its lower part. By increasing the travelling speed, the depth of the laser treated zone was decreases, while travelling speed has much less significant effect on the laser treated zone width. The size of the formed martensite plates was increased by decreasing the travelling speed from 1500 to 500 mm min-1. On the other hand, the travelling speed has a straight effect on the length of the acicular martensite; as the travelling speed increases, the acicular martensite became longer, while it shows fine acicular martensite at lower travelling speeds. The depth that full martensite structure can be reached is increased by increasing travelling speed. At lower travelling speed (500 mm min-1, large amount of bainite structure is observed at the center of the treated zone up to its lower end. The

  5. Graphene crystal growth by thermal precipitation of focused ion beam induced deposition of carbon precursor via patterned-iron thin layers

    Directory of Open Access Journals (Sweden)

    Rius Gemma

    2014-01-01

    Full Text Available Recently, relevant advances on graphene as a building block of integrated circuits (ICs have been demonstrated. Graphene growth and device fabrication related processing has been steadily and intensively powered due to commercial interest; however, there are many challenges associated with the incorporation of graphene into commercial applications which includes challenges associated with the synthesis of this material. Specifically, the controlled deposition of single layer large single crystal graphene on arbitrary supports, is particularly challenging. Previously, we have reported the first demonstration of the transformation of focused ion beam induced deposition of carbon (FIBID-C into patterned graphitic layers by metal-assisted thermal treatment (Ni foils. In this present work, we continue exploiting the FIBID-C approach as a route for graphene deposition. Here, thin patterned Fe layers are used for the catalysis of graphenization and graphitization. We demonstrate the formation of high quality single and few layer graphene, which evidences, the possibility of using Fe as a catalyst for graphene deposition. The mechanism is understood as the minute precipitation of atomic carbon after supersaturation of some iron carbides formed under a high temperature treatment. As a consequence of the complete wetting of FIBID-C and patterned Fe layers, which enable graphene growth, the as-deposited patterns do not preserve their original shape after the thermal treatment

  6. Elemental compositions of PM10–2.5 and PM2.5 aerosols of a Nigerian urban city using ion beam analytical techniques

    International Nuclear Information System (INIS)

    The paucity of data on air quality studies in Nigeria prompted us to commence the sampling of particulate matter (PM10–2.5 and PM2.5) in Mushin Lagos, Nigeria. Both size-segregated fractions were collected using a double staged ‘Gent’ stack filter unit sampler. Elemental characterization was carried out by Particle Induced X-ray Emission (PIXE) and Proton Induced γ-ray Emission (PIGE) techniques using an external ion beam set-up. Twenty-four elements (Na, Mg, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Se, Br, Rb, Sr, Zr, Cs and Pb) were detected in both fractions and their concentrations were assessed. A study of their inter-elemental correlations indicated that some elements could have common source origins or similar chemical properties while enrichment factors (EF) displayed that most elements emanated from anthropogenic sources. Source apportionment studies are thus recommended

  7. 10 cm range two-resonator electron accelerator with a bridge circuit of power supply and deep control of energy and beam current

    International Nuclear Information System (INIS)

    Description and nominal parameters of a resonator accelerator of vaciable energy from tens keV to 1 MeV and pulse current from units to hundreds of milliamperes for using in semiconductor defectoscopy and simulation of electrostatic shields under earth conditions are presented. An accelerating system consists of two 10 cm-wave length resonators supplied with HF power through three-decibel directional coupler. A serial autogenerator-1.3 MW pulse power magnetron is a power supply. A vacuum system contains two small zeolite pumps and the HOPD-100 electrocharge pump. An electron gun with the Trenyeva geometry producing 40 keV electron beam and 7A pulse current serves an injector. Control panel is used for distance accelerator control

  8. Induced radioactivity of a GSO scintillator by secondary fragments in carbon ion therapy and its effects on in-beam OpenPET imaging

    Science.gov (United States)

    Hirano, Yoshiyuki; Nitta, Munetaka; Nishikido, Fumihiko; Yoshida, Eiji; Inadama, Naoko; Yamaya, Taiga

    2016-07-01

    The accumulation of induced radioactivity within in-beam PET scanner scintillators is of concern for its long-term clinical usage in particle therapy. To estimate the effects on OpenPET which we are developing for in-beam PET based on GSOZ (Zi doped Gd2SiO5), we measured the induced radioactivity of GSO activated by secondary fragments in a water phantom irradiation by a 12C beam with an energy of 290 MeV u‑1. Radioisotopes of Na, Ce, Eu, Gd, Nd, Pm and Tb including positron emitters were observed in the gamma ray spectra of the activated GSO with a high purity Ge detector and their absolute radioactivities were calculated. We used the Monte Carlo simulation platform, Geant4 in which the observed radioactivity was assigned to the scintillators of a precisely reproduced OpenPET and the single and coincidence rates immediately after one treatment and after one-year usage were estimated for the most severe conditions. Comparing the highest coincidence rate originating from the activated scintillators (background) and the expected coincidence rate from an imaging object (signal), we determined the expected signal-to-noise ratio to be more than 7 within 3 min and more than 10 within 1 min from the scan start time. We concluded the effects of scintillator activation and their accumulation on the OpenPET imaging were small and clinical long-term usage of the OpenPET was feasible.

  9. CV-Dust: Atmospheric aerosol in the Cape Verde region: carbon and soluble fractions of PM10

    Science.gov (United States)

    Pio, C.; Nunes, T.; Cardoso, J.; Caseiro, A.; Custódio, D.; Cerqueira, M.; Patoilo, D.; Almeida, S. M.; Freitas, M. C.

    2012-04-01

    than 100 PM10 samples, addressing mainly their mass concentrations and the chemical composition of water soluble ions and carbon species (carbonates and organic and elemental carbon). Different PM10 samplers worked simultaneously in order to collect enough mass to make the aerosol characterization through the different methodologies and to collect aerosols in different filter matrixes, which have to be appropriated to the chemical and mineralogical analysis. The sampling site was located at Santiago Island, in the surroundings of Praia City (14° 55' N e 23° 29' W, 98 m at sea level). High concentrations, up to more than 400 μg m-3, are connected to north-east and north-northeast winds, and it was identified several dust events characteristic of "bruma seca", whose duration is on average of two to four days. Backward trajectories analysis confirms that the high concentrations in Cape Verde are associated with air masses passing over the Sahara. During dust events the percentage of inorganic water soluble ions for the total PM10 mass concentration decreased significantly to values lower than 10% in comparison with remainder data that range around 45±10%. Acknowledgement: This work was funded by the Portuguese Science Foundation (FCT) through the project PTDD/AAC-CLI/100331/2008 and FCOMP-01-0124-FEDER-008646 (CV-Dust). J. Cardoso acknowledges the PhD grant SFRH-BD-6105-2009 from FCT.

  10. Laser beam welding quality monitoring system based in high-speed (10 kHz) uncooled MWIR imaging sensors

    Science.gov (United States)

    Linares, Rodrigo; Vergara, German; Gutiérrez, Raúl; Fernández, Carlos; Villamayor, Víctor; Gómez, Luis; González-Camino, Maria; Baldasano, Arturo; Castro, G.; Arias, R.; Lapido, Y.; Rodríguez, J.; Romero, Pablo

    2015-05-01

    The combination of flexibility, productivity, precision and zero-defect manufacturing in future laser-based equipment are a major challenge that faces this enabling technology. New sensors for online monitoring and real-time control of laserbased processes are necessary for improving products quality and increasing manufacture yields. New approaches to fully automate processes towards zero-defect manufacturing demand smarter heads where lasers, optics, actuators, sensors and electronics will be integrated in a unique compact and affordable device. Many defects arising in laser-based manufacturing processes come from instabilities in the dynamics of the laser process. Temperature and heat dynamics are key parameters to be monitored. Low cost infrared imagers with high-speed of response will constitute the next generation of sensors to be implemented in future monitoring and control systems for laser-based processes, capable to provide simultaneous information about heat dynamics and spatial distribution. This work describes the result of using an innovative low-cost high-speed infrared imager based on the first quantum infrared imager monolithically integrated with Si-CMOS ROIC of the market. The sensor is able to provide low resolution images at frame rates up to 10 KHz in uncooled operation at the same cost as traditional infrared spot detectors. In order to demonstrate the capabilities of the new sensor technology, a low-cost camera was assembled on a standard production laser welding head, allowing to register melting pool images at frame rates of 10 kHz. In addition, a specific software was developed for defect detection and classification. Multiple laser welding processes were recorded with the aim to study the performance of the system and its application to the real-time monitoring of laser welding processes. During the experiments, different types of defects were produced and monitored. The classifier was fed with the experimental images obtained. Self

  11. Including a full carbon cycle into the iLOVECLIM model (v1.0)

    OpenAIRE

    N. Bouttes; Roche, D. M.; V. Mariotti-Epelbaum; L. Bopp

    2014-01-01

    The atmospheric carbon dioxide concentration plays a crucial role in the radiative balance and as such has a strong influence on the evolution of climate. Because of the numerous interactions between climate and the carbon cycle, it is necessary to include a model of the carbon cycle within a climate model to understand and simulate past and future changes of the carbon cycle. In particular, natural variations of atmospheric CO2 have happened in the past, wh...

  12. Preliminary study of window silicate glass powder for EPR dosimetry with 10-MeV electron beam irradiation

    International Nuclear Information System (INIS)

    Window silicate glass powder has been evaluated as a possible high dose dosimeter using EPR (Electron Paramagnetic Resonance) technique. In this work window glass powder with maximum dimension of 700 μm was irradiated with 10 MeV electrons with doses ranging from 580 Gy to 46.52 kGy. The EPR response of the irradiated samples showed a linear behavior to applied doses up to 8 kGy. The EPR spectra of NBOHC (Non-Bonding Oxygen Hole Center) was found at g1 = 2.0092 ± 0.0001 and g2 = 2.0042 ± 0.0001. The line widths of all spectra were found to be the same. Finally, the thermal fading of EPR intensity was studied for 70 days and showed a sharp decline on the first day. This fading continued up to almost 15 days and then the slope of the decay-curve tended to gradual changes up to 50 days. Afterwards, it presented a fairly constant value with time and a predictable stability was achieved.

  13. ATA diagnostic beam dump conceptual design

    International Nuclear Information System (INIS)

    A diagnostic beam dump, able to withstand 72,000 pulses (10 kA, 50 MeV/pulse) per shift was designed and analyzed. The analysis shows that the conceptual beam dump design consisting of 80 vitreous carbon plate-foam elements is able to withstand the thermal and mechanical stresses generated. X-rays produced by bremsstrahlung are absorbed by a three element copper plate-foam x-ray absorber. Cooling between bursts of electron pulses is provided by pressurized helium

  14. Properties of carbon-based structures synthesized in nuclear reactions induced by bremsstrahlung γ quanta with threshold energy of 10 MeV at helium pressure of 1.1 kbar

    Science.gov (United States)

    Didyk, A. Yu.; Wiśniewski, R.

    2016-07-01

    Helium gas with an initial pressure of about 1.1 kbar inside a high-pressure chamber (HeHPC) has been irradiated by bremsstrahlung γ quanta with a threshold energy of 10 MeV for 1.0 × 105 s produced by an electron-beam current of 22-24 μA. After opening the HeHPC, the residual pressure of helium is equal to 430 bar. Synthesized black foils with a variety of other objects are found inside the HeHPC. They are located on the inner surfaces of the reaction chamber made of high-purity copper (99.99%), the entrance the window of γ quanta made of beryllium bronze and a copper container of nuclear and chemical reaction products. Elemental analysis with the use of scanning electron microscopy and X-ray microprobe analysis has revealed that the foils contain predominantly carbon and small quantities of other elements from carbon to iron. The results are in good agreement with the cycle of investigations of the authors devoted to the γ-quanta irradiation of dense hydrogen and helium gases in the presence (absence) of metals in a reaction chamber.

  15. Simulation study on light ions identification methods for carbon beams from 95 to 400 MeV/A

    CERN Document Server

    Salvador, S; Fontbonne, J M; Dudouet, J; Colin, J; Cussol, D

    2013-01-01

    Monte Carlo simulations have been performed in order to evaluate the efficiencies of several light ions identification techniques. The detection system was composed with layers of scintillating material to measure either the deposited energy or the time-of-flight of ions produced by nuclear reactions between 12C projectiles and a PMMA target. Well known techniques such as (DELTA) E--Range, (DELTA) E--E--ToF and (DELTA)E--E are presented and their particle identification efficiencies are compared one to another regarding the generated charge and mass of the particle to be identified. The simulations allowed to change the beam energy matching the ones proposed in an hadron therapy facility, namely from 95 to 400 MeV/A.

  16. Obtention of thermoluminescent efficiencies by means of irradiation of TLD-100 dosemeters with proton beams helium and carbon

    International Nuclear Information System (INIS)

    In this work, the advances of a serial of measurements of relative efficiency thermoluminescent of heavy charged particles (PCP) with respect to gamma radiation for TLD-100, dosemeters of LiF: Mg,Ti manufactured by the Harshaw-Bicron company are reported. The PCP are essentials in the implementation of dosimetry associated with medical applications. The measurements before gamma radiation were carrying out using the Vickrad irradiator of the National Institute of Nuclear Research at dose of 1.663 Gy. The measures which are reported about protons, helium and carbon were realized using the Pelletron accelerator of the Physics Institute of the UNAM. (Author)

  17. Comparison between computed and measured response of silicon strip detectors exposed to carbon, calcium and ruthenium ion beams

    International Nuclear Information System (INIS)

    The response of silicon strip detectors exposed to energetic heavy ions in the energy interval from 0.3 up to 1.4 GeV/u has been measured at the SIS accelerator at GSI. The energy deposit spectra are characterized by their mean values and widths. The carbon data, at various energies, agree within the accuracy of the measurements with the computed response of the detector. The measured widths of the energy deposit spectra for ruthenium are narrower than those calculated by the appropriate Vavilov distributions. Energetic δ-rays overflowing from the silicon detector is considered as a possible explanation for the disagreement between computed and measured widths

  18. Comparison between computed and measured response of silicon strip detectors exposed to carbon, calcium and ruthenium ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Codino, A. E-mail: antonio.codino@codino-pc.pg.infn.it; Plouin, F.; Bellachioma, C.; Brunetti, M.T.; Checcucci, B.; Federico, C.; Lanfranchi, M.; Maffei, P.; Miozza, M.; Vocca, H

    2003-09-01

    The response of silicon strip detectors exposed to energetic heavy ions in the energy interval from 0.3 up to 1.4 GeV/u has been measured at the SIS accelerator at GSI. The energy deposit spectra are characterized by their mean values and widths. The carbon data, at various energies, agree within the accuracy of the measurements with the computed response of the detector. The measured widths of the energy deposit spectra for ruthenium are narrower than those calculated by the appropriate Vavilov distributions. Energetic {delta}-rays overflowing from the silicon detector is considered as a possible explanation for the disagreement between computed and measured widths.

  19. Thermometry using 1/8 W carbon resistors in a temperature region around 10 mK

    International Nuclear Information System (INIS)

    The resistance-temperature characteristics of 1/8 W carbon resistors of grade ERC-18SG, manufactured by Matsushita, with the nominal values of 48, 82, 100, 220 and 330 Ω have been measured in the region 4.2 K to 25 mK and their application as thermometers in this region is confirmed. For the 82 Ω resistor, measurements were taken at temperatures below 10mK. The temperature dependence of the resistance was found to be linear on the log-log plot over a wide range below 50 mK. The sensitivity remains finite even at 6 mK, but below 10 mK rapid measurements were prevented by a considerable increase in the thermal relaxation time. Measurement of the characteristics of several 100 Ω resistors from two different sets showed that resistors from the same set separate into two groups with different characteristics. This become appreciable at temperatures below 4.2 K, so it is difficult to predict the behaviour of Matsushite resistors below 4.2 K from the characteristics at higher temperatures. (author)

  20. A comparison study between atomic and ionic nitrogen doped carbon films prepared by ion beam assisted cathode arc deposition at various pulse frequencies

    International Nuclear Information System (INIS)

    A comparison study of microstructure and bonds composition of carbon nitride (CNx) films fabricated at atomic and ionic nitrogen source by pulse cathode arc method was presented. The relative fractions of CN/CC bonds, N-sp3C/N-sp2C and graphite-like/pyridine-like N bonding configurations in the CN films were evaluated by combining C1s and N1s X-ray photoelectron spectroscopy with the hardness and optical band gap measurement. The dependence of microstructure (quantity, size and disordering degree of Csp2 clusters) of CNx films on the nitrogen source and pulse frequency was determined by Raman spectroscopy. Films with high atomic ratio of nitrogen/carbon (0.17) and high hardness were produced at ionic nitrogen source and low pulse frequency. The results showed that ionic nitrogen source facilitated the formation of CN bonds and N-sp2C bonding configurations (mainly in graphite-like N form). Moreover presenting an optimum pulse frequency (∼10 Hz) leaded to the most nitrogen coordinated with sp3-C and the highest ratio of CN/CC bonds in the CNx films. An equilibrium action mechanism might exist between the quantity and energy of carbon and nitrogen ions/atoms, giving more nitrogen-incorporated carbon materials. These allow us to obtain the high content of N-Csp3 bonding and expected bonding structure by optimizing pulse frequency and nitrogen source.

  1. Enhanced field electron emission from aligned diamond-like carbon nanorod arrays prepared by reactive ion beam etching

    Science.gov (United States)

    Zhao, Yong; Qin, Shi-Qiao; Zhang, Xue-Ao; Chang, Sheng-Li; Li, Hui-Hui; Yuan, Ji-Ren

    2016-05-01

    Homogeneous diamond-like carbon (DLC) films were deposited on Si supports by a pulsed filtered cathodic vacuum arc deposition system. Using DLC films masked by Ni nanoparticles as precursors, highly aligned diamond-like carbon nanorod (DLCNR) arrays were fabricated by the etching of inductively coupled radio frequency oxygen plasma. The as-prepared DLCNR arrays exhibit excellent field emission properties with a low turn-on field of 2.005 V μm‑1 and a threshold field of 4.312 V μm‑1, respectively. Raman spectroscopy and x-ray photoelectron spectroscopy were employed to determine the chemical bonding structural change of DLC films before and after etching. It is confirmed that DLC films have good connection with Si supports via the formation of the SiC phase, and larger conductive sp2 domains are formed in the as-etched DLC films, which play essential roles in the enhanced field emission properties for DLCNR arrays.

  2. Intense positron beams: linacs

    International Nuclear Information System (INIS)

    Beams of monoenergetic positrons with energies of a few eV to many keV have been used in experiments in atomic physics, solid-state physics and materials science. The production of positron beams from a new source, an electron linac, is described. Intense, pulsed beams of low-energy positrons were produced by a high-energy beam from an electron linac. The production efficiency, moderator geometry, beam spot size and other positron beam parameters were determined for electrons with energies from 60 to 120 MeV. Low-energy positron beams produced with a high-energy electron linac can be of much higher intensity than those beams currently derived from radioactive sources. These higher intensity beams will make possible positron experiments previously infeasible. 10 references, 1 figure

  3. Muon Beam at the Fermilab Test Beam Area

    OpenAIRE

    Denisov, Dmitri; Evdokimov, Valery; Lukić, Strahinja; Ujić, Predrag

    2016-01-01

    The intensities and profiles of the muon beam behind the beam dump of the Fermilab test beam area when the facility is running in the "pion" beam mode are measured and summarized in this note. This muon beam with momenta in the range 10 - 50 GeV/c provides an opportunity to perform various measurements in parallel with other users of the test beam area.

  4. Current State Of Proton And Carbon-Ion Radiotherapy At The Hyogo Ion Beam Medical Center (HIBMC)

    Science.gov (United States)

    Murakami, Masao; Demizu, Yusuke; Niwa, Yasue; Fujii, Osamu; Terashima, Kazuki; Mima, Masayuki; Miyawaki, Daisuke; Sasaki, Ryohei; Hishikawa, Yoshio; Abe, Mitsuyuki

    2011-06-01

    HIBMC is the world's first facility to be able to use both proton (PRT) and carbon-ion radiotherapy (CiRT). The medically dedicated synchrotron can accelerate protons up to 230 MeV and carbon ions up to 320 MeV. From April 2001 to March 2010, the facility treated 3275 patients, with 2487 patients treated using PRT and 788 using CiRT. Particle radiotherapy was delivered to patients suffering from malignant tumors originating in the head and neck (502 patients), lungs (330), liver (539), prostate (1283), and the bone & soft tissue (130). The clinical results are as follows: (1) H & N tumors: The 2-year overall survival (OS) rates of patients with olfactory neuroblastoma, mucoepidermoid cancer, adenoid cystic cancer, adenocarcinoma, squamous cell carcinoma, and malignant melanoma was 100%, 86%, 78%, 78%, 66%, and 62%, respectively. (2) Lung cancer: For all 80 patients, the 3-year OS rate was 75% (Stage IA: 74%; Stage IB: 76%) and local control (LC) rate was 82% (IA: 87%; IB: 77%). Grade 3 pulmonary toxicity was observed in only 1 patient. These results are comparable to those obtained by surgery, and indicate proton therapy and carbon-ion therapy are safe and effective for stage I lung cancer. (3) Liver cancer: The 5-year LC rate for 429 tumor patient was 90%, and the 5-year OS rate for 364 patients was 38%. These results seem equivalent to those obtained by surgery or radio-frequency ablation. (4) Prostate cancer: In 290 patients treated by proton radiotherapy, five patients died from other disease in the median follow-up period of 62 months. Biochemical disease-free survival and OS rate at 5 years was 88.2% and 96.5%, respectively. Our proton radiotherapy showed excellent OS and biochemical disease-free survival rates with minimum late morbidities. PRT VS CiRT: From our retrospective analysis, it seems that there is no significant difference in the LC and OS rate in H&N, lung and liver cancer between PRT and CiRT.

  5. Current State Of Proton And Carbon-Ion Radiotherapy At The Hyogo Ion Beam Medical Center (HIBMC)

    International Nuclear Information System (INIS)

    HIBMC is the world's first facility to be able to use both proton (PRT) and carbon-ion radiotherapy (CiRT). The medically dedicated synchrotron can accelerate protons up to 230 MeV and carbon ions up to 320 MeV. From April 2001 to March 2010, the facility treated 3275 patients, with 2487 patients treated using PRT and 788 using CiRT. Particle radiotherapy was delivered to patients suffering from malignant tumors originating in the head and neck (502 patients), lungs (330), liver (539), prostate (1283), and the bone and soft tissue (130). The clinical results are as follows: (1) H and N tumors: The 2-year overall survival (OS) rates of patients with olfactory neuroblastoma, mucoepidermoid cancer, adenoid cystic cancer, adenocarcinoma, squamous cell carcinoma, and malignant melanoma was 100%, 86%, 78%, 78%, 66%, and 62%, respectively. (2) Lung cancer: For all 80 patients, the 3-year OS rate was 75%(Stage IA: 74%; Stage IB: 76%) and local control (LC) rate was 82%(IA: 87%; IB: 77%). Grade 3 pulmonary toxicity was observed in only 1 patient. These results are comparable to those obtained by surgery, and indicate proton therapy and carbon-ion therapy are safe and effective for stage I lung cancer. (3) Liver cancer: The 5-year LC rate for 429 tumor patient was 90%, and the 5-year OS rate for 364 patients was 38%. These results seem equivalent to those obtained by surgery or radio-frequency ablation. (4) Prostate cancer: In 290 patients treated by proton radiotherapy, five patients died from other disease in the median follow-up period of 62 months. Biochemical disease-free survival and OS rate at 5 years was 88.2% and 96.5%, respectively. Our proton radiotherapy showed excellent OS and biochemical disease-free survival rates with minimum late morbidities. PRT VS CiRT: From our retrospective analysis, it seems that there is no significant difference in the LC and OS rate in H and N, lung and liver cancer between PRT and CiRT.

  6. Low-Dose (10-Gy) Total Skin Electron Beam Therapy for Cutaneous T-Cell Lymphoma: An Open Clinical Study and Pooled Data Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kamstrup, Maria R., E-mail: mkam0004@bbh.regionh.dk [Department of Dermatology, Bispebjerg Hospital, University of Copenhagen, Copenhagen (Denmark); Gniadecki, Robert [Department of Dermatology, Bispebjerg Hospital, University of Copenhagen, Copenhagen (Denmark); Iversen, Lars [Department of Dermatology, Aarhus University Hospital, Aarhus (Denmark); Skov, Lone [Department of Dermatology, Gentofte Hospital, University of Copenhagen, Copenhagen (Denmark); Petersen, Peter Meidahl [Department of Oncology and Hematology, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Loft, Annika [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Specht, Lena [Department of Oncology and Hematology, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark)

    2015-05-01

    Purpose: Cutaneous T-cell lymphomas (CTCLs) are dominated by mycosis fungoides (MF) and Sézary syndrome (SS), and durable disease control is a therapeutic challenge. Standard total skin electron beam therapy (TSEBT) is an effective skin-directed therapy, but the possibility of retreatments is limited to 2 to 3 courses in a lifetime due to skin toxicity. This study aimed to determine the clinical effect of low-dose TSEBT in patients with MF and SS. Methods and Materials: In an open clinical study, 21 patients with MF/SS stages IB to IV were treated with low-dose TSEBT over <2.5 weeks, receiving a total dose of 10 Gy in 10 fractions. Data from 10 of these patients were published previously but were included in the current pooled data analysis. Outcome measures were response rate, duration of response, and toxicity. Results: The overall response rate was 95% with a complete cutaneous response or a very good partial response rate (<1% skin involvement with patches or plaques) documented in 57% of the patients. Median duration of overall cutaneous response was 174 days (5.8 months; range: 60-675 days). TSEBT-related acute adverse events (grade 1 or 2) were observed in 60% of patients. Conclusions: Low-dose (10-Gy) TSEBT offers a high overall response rate and is relatively safe. With this approach, reirradiation at times of relapse or progression is likely to be less toxic than standard dose TSEBT. It remains to be established whether adjuvant and combination treatments can prolong the beneficial effects of low-dose TSEBT.

  7. Low-Dose (10-Gy) Total Skin Electron Beam Therapy for Cutaneous T-Cell Lymphoma: An Open Clinical Study and Pooled Data Analysis

    International Nuclear Information System (INIS)

    Purpose: Cutaneous T-cell lymphomas (CTCLs) are dominated by mycosis fungoides (MF) and Sézary syndrome (SS), and durable disease control is a therapeutic challenge. Standard total skin electron beam therapy (TSEBT) is an effective skin-directed therapy, but the possibility of retreatments is limited to 2 to 3 courses in a lifetime due to skin toxicity. This study aimed to determine the clinical effect of low-dose TSEBT in patients with MF and SS. Methods and Materials: In an open clinical study, 21 patients with MF/SS stages IB to IV were treated with low-dose TSEBT over <2.5 weeks, receiving a total dose of 10 Gy in 10 fractions. Data from 10 of these patients were published previously but were included in the current pooled data analysis. Outcome measures were response rate, duration of response, and toxicity. Results: The overall response rate was 95% with a complete cutaneous response or a very good partial response rate (<1% skin involvement with patches or plaques) documented in 57% of the patients. Median duration of overall cutaneous response was 174 days (5.8 months; range: 60-675 days). TSEBT-related acute adverse events (grade 1 or 2) were observed in 60% of patients. Conclusions: Low-dose (10-Gy) TSEBT offers a high overall response rate and is relatively safe. With this approach, reirradiation at times of relapse or progression is likely to be less toxic than standard dose TSEBT. It remains to be established whether adjuvant and combination treatments can prolong the beneficial effects of low-dose TSEBT

  8. Spectrometry of linear energy transfer with track-etched detectors in carbon ion beams, MONO and SOBP

    Czech Academy of Sciences Publication Activity Database

    Pachnerová Brabcová, Kateřina; Ambrožová, Iva; Spurný, František

    2011-01-01

    Roč. 143, 2-4 (2011), s. 440-444. ISSN 0144-8420. [International Symposium on Microdosimetry/15./. Verona, 25.10.2009-30.10.2009] R&D Projects: GA ČR GA205/09/0171; GA AV ČR IAA100480902 Institutional research plan: CEZ:AV0Z10480505 Keywords : particles * HIMAC * track-etched detectors Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 0.822, year: 2011

  9. Microchannel plate based detector for a heavy ion beam spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Green, M.I.

    1979-10-01

    The design parameters and operating characteristics of the detector used in the Brutus and Fannie heavy ion beam spectrometers at the SuperHILAC facility are described. The detector utilizes a 25 mm diameter microchannel plate array to obtain gains of 10/sup 2/ to 10/sup 8/ with a linear dynamic range of 10/sup 3/. It has had over three years of almost maintenance-free service, detecting ion beams from carbon to xenon with energies between 1.2 and 8.5 MeV per nucleon.

  10. Different morphological effects of γ-rays and boron-10 neutron captured beams on the vegetative cells of Closterium ehrenbergii (green alga)

    International Nuclear Information System (INIS)

    Different cyto-morphological effects of γ-rays and 10B neutron captured beams (BNCB), 10B(n,α)7Li on the cells of Closterium ehrenbergii Meneghini (Chlorophyta) were studied at the stationary phase of cell growth. For BNCB, about 75% of absorbed dose was estimated to be due to α particles and recoiled lithium nuclei. Relative biological effectiveness of BNCB compared to γ-rays was ca. 5 at D37. Colony observations after γ-rays irradiation revealed that each dead cell in a single colony had different morphology at 2- to 4-cell stages. However, after BNCB irradiation, the morphology of some sister cells in a colony was the same or very similar to each other. These qualitative differences of radiation response between γ-rays and BNCB were probably due to the difference in LET. DNA content of this alga is 2C in plateau phase. It was inferred genetically that the two sets of DNA double strands in this alga lie side by side at least partially at this stage, and that simultaneous modification in the same locus on the two sets of DNA strands caused the concurrence of morphologically abnormal sister cells. These abnormal cells could be classified into three major morphogroups which were subgrouped to 12 minor types from the view point of morphogenesis. (author)

  11. External-beam radiation therapy for age-related macular degeneration. Two years' follow-up results at a total dose of 20 Gy in 10 fractions

    International Nuclear Information System (INIS)

    The efficacy of external-beam radiation therapy (RT) was evaluated in the treatment of eyes with subfoveal or juxtafoveal choroidal neovascularization in age-related macular degeneration (ARMD). Twenty-one eyes of 18 patients with occult or mixed-type ARMD received a total dose of 20 Gy of 6 MV X-rays in 10 fractions. The follow-up time was 24 months. Fifteen non-treated eyes of 13 patients who had been followed served as a control. In the RT group, visual acuity was improved in three eyes, maintained in 14 eyes, and worsened in four eyes. In the control group, it was not improved in any eyes, was maintained in six eyes, and worsened in nine eyes. The improved or maintained rate in visual acuity was 81% in the RT group and 40% in the control group (p=0.0342). In the RT group, fundoscopic and angiographic findings were improved in five eyes, unchanged in seven eyes, and worsened in nine eyes, while they were not improved in any eyes, unchanged in two eyes, and worsened in 13 eyes in the control group (p=0.0342). RT at a total dose of 20 Gy in 10 fractions is effective for ARMD for at least two years. RT may be effective treatment for occult or mixed-type ARMD compared with the classic type. (author)

  12. Coupling carbon nanotube film microextraction with desorption corona beam ionization for rapid analysis of Sudan dyes (I-IV) and Rhodamine B in chilli oil.

    Science.gov (United States)

    Chen, Di; Huang, Yun-Qing; He, Xiao-Mei; Shi, Zhi-Guo; Feng, Yu-Qi

    2015-03-01

    A rapid analysis method by coupling carbon nanotube film (CNTF) microextraction with desorption corona beam ionization (DCBI) was developed for the determination of Sudan dyes (I-IV) and Rhodamine B in chilli oil samples. Typically, CNTF was immersed into the diluted solution of chilli oil for extraction, which was then placed directly under the visible plasma beam tip of the DCBI source for desorption and ionization. Under optimized conditions, five dyes were simultaneously determined using this method. Results showed that the analytes were enriched by the CNTF through the π-π interactions, and the proposed method could significantly improve the sensitivities of these compounds, compared to the direct analysis by DCBI-MS/MS. The method with a linear range of 0.08-12.8 μg g(-1) and good linear relationships (R(2) > 0.93) in a multiple reaction monitoring (MRM) mode was developed. Satisfactory reproducibility was achieved. Relative standard deviations (RSDs) were less than 20.0%. The recoveries ranged from 80.0 to 110.0%, and the limits of detection (LODs) were in the range of 1.4-21 ng g(-1). Finally, the feasibility of the method was further exhibited by the determination of five illegal dyes in chilli powder. These results demonstrate that the proposed method consumes less time and solvent than conventional HPLC-based methods and avoids the contamination of chromatographic column and ion source from non-volatile oil. With the help of a 72-well shaker, multiple samples could be treated simultaneously, which ensures high throughput for the entire pretreatment process. In conclusion, it provides a rapid and high-throughput approach for the determination of such illicit additions in chilli products. PMID:25619730

  13. The relative biological effectiveness for carbon and oxygen ion beams using the raster-scanning technique in hepatocellular carcinoma cell lines.

    Directory of Open Access Journals (Sweden)

    Daniel Habermehl

    Full Text Available BACKGROUND: Aim of this study was to evaluate the relative biological effectiveness (RBE of carbon (12C and oxygen ion (16O-irradiation applied in the raster-scanning technique at the Heidelberg Ion beam Therapy center (HIT based on clonogenic survival in hepatocellular carcinoma cell lines compared to photon irradiation. METHODS: Four human HCC lines Hep3B, PLC, HepG2 and HUH7 were irradiated with photons, 12C and 16O using a customized experimental setting at HIT for in-vitro trials. Cells were irradiated with increasing physical photon single doses of 0, 2, 4 and 6 Gy and heavy ion-single doses of 0, 0.125, 0.5, 1, 2, 3 Gy (12C and 16O. SOBP-penetration depth and extension was 35 mm +/-4 mm and 36 mm +/-5 mm for carbon ions and oxygen ions respectively. Mean energy level and mean linear energy transfer (LET were 130 MeV/u and 112 keV/um for 12C, and 154 MeV/u and 146 keV/um for 16O. Clonogenic survival was computated and relative biological effectiveness (RBE values were defined. RESULTS: For all cell lines and both particle modalities α- and β-values were determined. As expected, α-values were significantly higher for 12C and 16O than for photons, reflecting a steeper decline of the initial slope of the survival curves for high-LET beams. RBE-values were in the range of 2.1-3.3 and 1.9-3.1 for 12C and 16O, respectively. CONCLUSION: Both irradiation with 12C and 16O using the raster-scanning technique leads to an enhanced RBE in HCC cell lines. No relevant differences between achieved RBE-values for 12C and 16O were found. Results of this work will further influence biological-adapted treatment planning for HCC patients that will undergo particle therapy with 12C or 16O.

  14. Formulation of an organic carbon trajectory over a 10-year period on a restored spoil island in south-central Florida

    Science.gov (United States)

    Schafer, T.; Ellis, R.; Osborne, T.; Hicks Pries, C.

    2015-12-01

    Long-term monitoring of restoration projects aims to determine long-term sustainability and stability of restored systems. In coastal wetlands, one indicator of restoration of ecosystem function can be seen with organic matter (specifically carbon) accretion. SL-15, a spoil island in Fort Pierce, Fl was restored in 2005, and has been monitored for return to natural condition over the last 10 years.. To assess sediment carbon accretion, sediment cores were collected in a set of eight plots, located on the SL-15 mangrove island and the surrounding seagrass recruitment area. These were analyzed for organic carbon, microbial biomass carbon, extractable carbon, and total nitrogen. The biogeochemical data collected in the previous year was compared to data collected in 2005-2007. Vegetation surveys were also completed to show the build-up of organic material in accordance with vegetation shift over the 9-year period. From this information, a trajectory has been formulated on organic carbon accretion and vegetation shift from the time of orginal restoration activities. By comparison to control sites nearby, realistic estimates of time required to reach natural levels of carbon and vegetation community structure can be calculated..

  15. Highly selective electrodeposition of sub-10 nm crystalline noble metallic nanorods inside vertically aligned multiwall carbon nanotubes.

    Science.gov (United States)

    Wang, Xuyang; Wang, Ranran; Wu, Qiang; Zhang, Xiaohua; Yang, Zhaohui; Guo, Jun; Chen, Muzi; Tang, Minghua; Cheng, Yajun; Chu, Haibin

    2016-07-01

    In this paper crystalline noble metallic nanorods including Au and Ag with sub-10 nm diameter, are encapsulated within prealigned and open-ended multiwall carbon nanotubes (MWCNTs) through an electrodeposition method. As the external surface of CNTs has been insulated by the epoxy the CNT channel becomes the only path for the mass transport as well as the nanoreactor for the metal deposition. Highly crystallized Au and Ag2O nanorods parallel to the radial direction of CNTs are confirmed by high-resolution transmission electron microscopy, energy dispersive x-ray spectroscopy and x-ray powder diffraction spectroscopy. The Ag2O nanorods are formed by air oxidation on the Ag metals and show a single crystalline structure with (111) planes. The Au nanorods exhibit a complex crystalline structure including twin-crystal and lattice dislocation with (111) and (200) planes. These crystalline noble metallic nanostructures may have important applications for nanocatalysts for fuel cells as well as nanoelectronic and nanophotonic devices. This method is deemed to benefit the precise deposition of other crystalline nanostructures inside CNTs with a small diameter. PMID:27240546

  16. Isothermal Reduction of Oxide Scale on Hot-Rolled, Low-Carbon Steel in 10 pct H2-Ar

    Science.gov (United States)

    He, Yongquan; Jia, Tao; Li, Zhifeng; Cao, Guangming; Liu, Zhenyu; Li, Jun

    2016-08-01

    The isothermal reduction of oxide scale on hot-rolled, low-carbon steel strip in 10 pct H2-Ar mixtures in the temperature range of 673 K to 1073 K (400 °C to 800 °C) was investigated by using a thermo-gravimetric analyzer (TGA). During heating under an argon atmosphere, magnetite/iron eutectoid and proeutectoid magnetite in the oxide scale successively transformed into wüstite at a temperature above 843 K (570 °C). The kinetic plot of the isothermal reduction assumes a sigmoid shape, including induction, acceleration, and finally the decaying stage. Fitting the kinetic curve to mathematical models, the reaction at 1073 K (800 °C) and 773 K (500 °C) were determined to be controlled by phase-boundary-controlled reaction and three-dimensional growth of nuclei, respectively. The reduction product varies with temperature and itself affects the kinetics. Porous and dense iron were, respectively, obtained below and above 873 K (600 °C). A "rate-minimum" was observed at 973 K (700 °C) due to the formation of dense iron that blocks the gas diffusion. Due to the structural transformation of oxide scale during heating, the reactant depends on the heating process. However, compared with the oxide scale structure, the temperature is more important in determining the reduction kinetics at temperatures above 973 K (700 °C).

  17. Effects of changes in residential end-uses and behavior on aggregate carbon intensity. Comparison of 10 OECD countries for the period 1970 through 1993

    Energy Technology Data Exchange (ETDEWEB)

    Greening, L.A. [Consultant, 7780 Heights Court, Falls Church, VA 22043 Marshall (United States); Ting, M.; Krackler, T.J. [Energy and Environmental Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States)

    2001-03-01

    Patterns of the evolution of aggregate carbon intensity from residential end uses show greater variability than other sectors. For some countries in this analysis, this measure exhibits significant decreases, while for other countries this measure exhibits significant increases over the period of analysis. The Adaptive Weighted Divisia rolling base year index specification is applied to carbon emissions from the residential sector for 10 OECD countries for the period 1970-1993. Decreases in aggregate carbon intensity for six of the countries range less than 8% to almost 72%, and may be attributed to changes in three different factors. However, for all of the countries, decreases are offset by shifts in end-use structure toward more carbon-intensive activities. These shifts are driven by an increase in the number of households with a corresponding increase in floor space, acquisition of greater numbers of major appliances and by an increase in the 'other' energy consumption category.

  18. Influence of deposition parameters on surface roughness and mechanical properties of boron carbon nitride coatings synthesized by ion beam assisted deposition

    International Nuclear Information System (INIS)

    Boron carbon nitride (BCN) coatings were deposited on Si(100) wafers and Si3N4 disks by using ion beam assisted deposition from a boron carbide target. The BCN coatings were synthesized by the reaction between boron and carbon vapor as well as nitrogen ion simultaneously. The influence of deposition parameters such as ion acceleration voltage, ion acceleration current density and deposition ratio on the surface roughness and mechanical properties of the BCN coatings was investigated. The surface roughness was determined by using atomic force microscopy and the mechanical properties of the BCN coatings were evaluated by nano-indentation tests and friction tests in N2 gas. The composition and chemical bonding of the BCN coatings were analyzed by using X-ray photoelectron spectroscopy. The results showed that the lower deposition rate, the smaller surface roughness and higher nano-hardness the BCN coatings were. The BCN coating with the smoothest surface (R a = 0.25 nm and R P-V = 2.8 nm) and the highest nanohardness of 33 GPa as well as excellent friction property were obtained at 0.5 nm/s and the nitrogen ions were generated at 2.0 kV and 60 μA/cm2, and the chemical composition of this BCN coating was 49 at.% B, 42 at.% C and 9 at.% N. Moreover, there were several bonding states such as B-N, B-C and C-N with B-C-N hybridization in this BCN coating

  19. Measurements of hydrogen, oxygen and carbon isotope ratios by SIRA 10 mass spectrometer and some problems of their quality assurance

    International Nuclear Information System (INIS)

    Full text: Hydrogen and oxygen are two chemical elements that combined between them forms the water molecules. Hydrogen has two stable isotopes 1H and 2H, with abundance, respectively, 99.985 % and 0.015 %, while the oxygen has three stable isotopes 16O, 17O, 18O with the abundance, respectively, 99.756 %, 0.039 %, 0.205 %. Hydrogen and oxygen stable isotopes, in our laboratory, are used in the hydrology and hydrogeology studies. The 'δ' values of hydrogen and oxygen of water samples are expressed in per mille with respect to SMOW, while, for carbon is expressed in per mille with respect to PDB. The isotopic compositions of these elements are measured using the SIRA 10 mass spectrometer, which is similar with the Nier mass spectrometer. SIRA 10 mass spectrometer, destined for the measurements of the isotopic ratios of the light elements, is equipped with double inlet system and with three collectors system (for the oxygen, carbon, nitrogen etc. isotopes) and double collector system for the hydrogen isotopes. The vacuum 10-9 torr is realized by the two oil diffusion pumps. The gas samples (H2, CO2, etc.) are admitted to the ion source of the mass spectrometer, where are transformed into positive ions by the electron impact. The magnetic field is normal to the path of the ions and is realized by a permanent magnet. The quality assurance of the 'δ' determination dependent from the preparation of the gas samples and from the measurements of the isotopic ratios. Stable isotopes hydrogen of the water samples are measured through the hydrogen gas which is gained from the water by the reduction reaction with metallic Zinc in a separate line, in vacuum conditions and high temperature. The reduction process of the water was occurred not normally because in the inside of the glass balloons seems water droplets. The different experiments of the changes the water quantity, Zinc quantity, dimensions of the metallic Zinc and the temperature of the reduction reaction didn

  20. 77 FR 31351 - Adequacy Determination for Aspen PM10 and Fort Collins Carbon Monoxide Maintenance Plans' Motor...

    Science.gov (United States)

    2012-05-25

    ... (69 FR 40004). In addition, in certain areas with monitored ambient carbon monoxide (CO) values... the National Ambient Air Quality Standard (NAAQS). The criteria by which we determine whether a SIP... AGENCY Adequacy Determination for Aspen PM and Fort Collins Carbon Monoxide Maintenance Plans'...

  1. Mechanically reinforced glass beams

    DEFF Research Database (Denmark)

    Nielsen, Jens Henrik; Olesen, John Forbes

    2007-01-01

    breakage without any warning or ductility, which can be catastrophic if no precautions are taken. One aspect of this issue is treated here by looking at the possibility of mechanically reinforcing glass beams in order to obtain ductile failure for such a structural component. A mechanically reinforced...... laminated float glass beam is constructed and tested in four-point bending. The beam consist of 4 layers of glass laminated together with a slack steel band glued onto the bottom face of the beam. The glass parts of the tested beams are \\SI{1700}{mm} long and \\SI{100}{mm} high, and the total width of one...... beam is \\SI{4\\times10}{mm}. It is reinforced with a \\SI{3}{mm} high steel band covering the full width of the beam. The experimental setup is described and results for this beam are presented. Furthermore, the results for three similar experiments with a \\SI{6}{mm} steel band reinforcement are briefly...

  2. Relationship between plant growth and cytological effect in root apical meristem after exposure of wheat dry seeds to carbon ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Qingfang [Radiobiology Laboratory, Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, Gansu Province 730000 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Wang, Zhuanzi; Zhou, Libin; Qu, Ying; Lu, Dong [Radiobiology Laboratory, Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, Gansu Province 730000 (China); Yu, Lixia; Du, Yan [Radiobiology Laboratory, Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, Gansu Province 730000 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Jin, Wenjie [Radiobiology Laboratory, Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, Gansu Province 730000 (China); Li, Wenjian, E-mail: wjli@impcas.ac.cn [Radiobiology Laboratory, Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, Gansu Province 730000 (China)

    2013-06-15

    In order to analyze the relationship between plant growth and cytological effects, wheat dry seeds were exposed to various doses of {sup 12}C{sup 6+} beams and the biological endpoints reflecting plant growth and root apical meristem (RAM) activities were investigated. The results showed that most of the seeds were able to germinate normally within all dose range, while the plant survival rate descended at higher doses. The seedling growth including root length and seedling height also decreased significantly at higher doses. Mitotic index (MI) in RAM had no changes at 10 and 20 Gy and decreased obviously at higher doses and the proportion of prophase cells had the same trend with MI. These data suggested that RAM cells experienced cell cycle arrest, which should be responsible for the inhibition of root growth after exposure to higher doses irradiation. Moreover, various types of chromosome aberrations (CAs) were observed in the mitotic cells. The frequencies of mitotic cells with lagging chromosomes and these with anaphase bridges peaked around 60 Gy, while the frequencies of these with fragments increased as the irradiation doses increased up to 200 Gy. The total frequencies of mitotic cells with CAs induced by irradiation increased significantly with the increasing doses. The serious damage of mitotic chromosomes maybe caused cell cycle arrest or cell death. These findings suggested that the influences of {sup 12}C{sup 6+} beams irradiation on plant growth were related to the alternation of mitotic activities and the chromosomal damages in RAM.

  3. Relationship between plant growth and cytological effect in root apical meristem after exposure of wheat dry seeds to carbon ion beams

    International Nuclear Information System (INIS)

    In order to analyze the relationship between plant growth and cytological effects, wheat dry seeds were exposed to various doses of 12C6+ beams and the biological endpoints reflecting plant growth and root apical meristem (RAM) activities were investigated. The results showed that most of the seeds were able to germinate normally within all dose range, while the plant survival rate descended at higher doses. The seedling growth including root length and seedling height also decreased significantly at higher doses. Mitotic index (MI) in RAM had no changes at 10 and 20 Gy and decreased obviously at higher doses and the proportion of prophase cells had the same trend with MI. These data suggested that RAM cells experienced cell cycle arrest, which should be responsible for the inhibition of root growth after exposure to higher doses irradiation. Moreover, various types of chromosome aberrations (CAs) were observed in the mitotic cells. The frequencies of mitotic cells with lagging chromosomes and these with anaphase bridges peaked around 60 Gy, while the frequencies of these with fragments increased as the irradiation doses increased up to 200 Gy. The total frequencies of mitotic cells with CAs induced by irradiation increased significantly with the increasing doses. The serious damage of mitotic chromosomes maybe caused cell cycle arrest or cell death. These findings suggested that the influences of 12C6+ beams irradiation on plant growth were related to the alternation of mitotic activities and the chromosomal damages in RAM

  4. Relationship between plant growth and cytological effect in root apical meristem after exposure of wheat dry seeds to carbon ion beams

    Science.gov (United States)

    Liu, Qingfang; Wang, Zhuanzi; Zhou, Libin; Qu, Ying; Lu, Dong; Yu, Lixia; Du, Yan; Jin, Wenjie; Li, Wenjian

    2013-06-01

    In order to analyze the relationship between plant growth and cytological effects, wheat dry seeds were exposed to various doses of 12C6+ beams and the biological endpoints reflecting plant growth and root apical meristem (RAM) activities were investigated. The results showed that most of the seeds were able to germinate normally within all dose range, while the plant survival rate descended at higher doses. The seedling growth including root length and seedling height also decreased significantly at higher doses. Mitotic index (MI) in RAM had no changes at 10 and 20 Gy and decreased obviously at higher doses and the proportion of prophase cells had the same trend with MI. These data suggested that RAM cells experienced cell cycle arrest, which should be responsible for the inhibition of root growth after exposure to higher doses irradiation. Moreover, various types of chromosome aberrations (CAs) were observed in the mitotic cells. The frequencies of mitotic cells with lagging chromosomes and these with anaphase bridges peaked around 60 Gy, while the frequencies of these with fragments increased as the irradiation doses increased up to 200 Gy. The total frequencies of mitotic cells with CAs induced by irradiation increased significantly with the increasing doses. The serious damage of mitotic chromosomes maybe caused cell cycle arrest or cell death. These findings suggested that the influences of 12C6+ beams irradiation on plant growth were related to the alternation of mitotic activities and the chromosomal damages in RAM.

  5. An overview of nuclear micro-beam analysis of surface and bulk fuel retention in carbon-fibre composites from Tore Supra

    International Nuclear Information System (INIS)

    Surface and bulk retention of deuterium in tiles of the pump limiter from Tore Supra was examined with nuclear reaction analysis using both standard and micro-beam techniques. The aim was to determine the variations in the content and distribution of fuel species in carbon-fibre composites. On plasma-facing surfaces from the deposition zone, the D content reaches 2.5 x 1019 cm-2 in about 8 μm thick top layer, but lateral differences reach even more than one order of magnitude. This is also measured in the erosion zone: 6.6 x 1017 cm-2 to 7.7 x 1018 cm-2 D atoms. Bulk content was examined on cross-sections opened by fracturing the tiles. Fuel is detected up to the depth of 1-1.5 mm beneath the plasma-facing surface in tiles from both the erosion and deposition zones. It occurs in bands, about 100 μm wide and several mm long, roughly parallel to the original plasma-facing surface.

  6. Rabi Wave Packets and Peculiarities of Raman Scattering in Carbon Nanotubes, Produced by High Energy Ion Beam Modification of Diamond Single Crystals

    CERN Document Server

    Yearchuck, Dmitry

    2011-01-01

    QED-model for multichain coupled qubit system, proposed in \\cite{Part1}, was confirmed by Raman scattering studies of quasi-1D carbon zigzag-shaped nanotubes (CZSNTs), produced by high energy ion beam modification of natural diamond single crystals. Multichain coupled qubit system represents itself Su-Schriffer-Heeger $\\sigma$-polaron lattice, formed in CZSNTs plus quantized external electromagnetic (EM) field. New quantum optics phenomenon - Rabi waves, predicted in \\cite{Slepyan_Yerchak} has experimentally been identified for the first time. It is shown, that Raman spectra in quasi-1D CZSNTs are quite different in comparison with well known Raman spectra in 2D those ones. They characterized by semiclassical consideration by the only one vibronic mode of Su-Schriffer-Heeger $\\sigma$-polaron lattice instead of longitudinal and transverse optical phonon $G^+$ and $G^-$modes and the out-of-plane radial breathing mode, which are observed in Raman spectra of 2D single wall nanotubes. It is consequence of 2D - 1D ...

  7. Near edge X-ray absorption fine structure study for optimization of hard diamond-like carbon film formation with Ar cluster ion beam

    International Nuclear Information System (INIS)

    Diamond-like carbon (DLC) film deposited using C60 vapor with simultaneous irradiation of an Ar cluster ion beam was characterized by a near edge X-ray absorption fine structure (NEXAFS), in order to optimize the hard DLC film deposition conditions. Contents of sp2 orbitals in the films, which were estimated from NEXAFS spectra, are 30% lower than that of a conventional DLC film deposited by a RF plasma method. Those contents were obtained under the flux ratio of the C60 molecules to the Ar cluster ions to range from 1 to 20, at 5keV of Ar cluster ion acceleration energy. Average hardness of the films was 50 GPa under these flux ratios. This hardness was three times higher than that of a conventional DLC film. Furthermore, the lowest sp2 content and above-mentioned high hardness were obtained at room temperature of the substrate when the depositions were performed in the range of the substrate temperature from room temperature to 250degC. (author)

  8. Near edge X-ray absorption fine structure study for optimization of hard diamond-like carbon film formation with Ar cluster ion beam

    CERN Document Server

    Kitagawa, T; Kanda, K; Shimizugawa, Y; Toyoda, N; Matsui, S; Yamada, I; Tsubakino, H; Matsuo, J

    2003-01-01

    Diamond-like carbon (DLC) film deposited using C sub 6 sub 0 vapor with simultaneous irradiation of an Ar cluster ion beam was characterized by a near edge X-ray absorption fine structure (NEXAFS), in order to optimize the hard DLC film deposition conditions. Contents of sp sup 2 orbitals in the films, which were estimated from NEXAFS spectra, are 30% lower than that of a conventional DLC film deposited by a RF plasma method. Those contents were obtained under the flux ratio of the C sub 6 sub 0 molecules to the Ar cluster ions to range from 1 to 20, at 5keV of Ar cluster ion acceleration energy. Average hardness of the films was 50 GPa under these flux ratios. This hardness was three times higher than that of a conventional DLC film. Furthermore, the lowest sp sup 2 content and above-mentioned high hardness were obtained at room temperature of the substrate when the depositions were performed in the range of the substrate temperature from room temperature to 250degC. (author)

  9. Radiation curing of carbon fibre composites

    International Nuclear Information System (INIS)

    Epoxy/carbon fibre reinforced composites were produced by means of e-beam irradiation through a pulsed 10 MeV electron beam accelerator. The matrix consisted of a difunctional epoxy monomer (DGEBA) and an initiator of cationic polymerisation, while the reinforcement was a unidirectional high modulus carbon fibre fabric. Dynamic mechanical thermal analysis was carried out in order to determine the cross-linking degree. The analysis pointed out a nonuniformity in the cross-linking degree of the e-beam cured panels, with the formation of clusters at low Tg (glass transition temperature) and clusters at high Tg. An out-of-mould post irradiation thermal treatment on e-beam cured samples provides a higher uniformity in the network although some slight degradation effects. Mode I delamination fracture toughness and Interlaminar Shear Strength (ISS) were also investigated by means of Double Cantilever Beam (DCB) and Short Beam Shear tests, respectively. Results from this mechanical characterisation allowed to correlate fracture toughness of the bulk matrix resin, cross-linking density and fibre/matrix interaction to the delamination fracture behaviour of the fibre reinforced material. - Highligths: • Epoxy/carbon fibre composites were produced by means of e-beam irradiation. • DMTA analysis pointed out a nonuniformity in the cross-linking degree of the material. • An out-of-mould post irradiation thermal treatment allows a higher uniformity. • Mechanical tests were interpreted on the basis of the cross-linking density and fibre/matrix interaction

  10. Carbonate measurements in PM10 near the marble quarries of Carrara (Italy) by infrared spectroscopy (FT-IR) and source apportionment by positive matrix factorization (PMF)

    Science.gov (United States)

    Cuccia, E.; Piazzalunga, A.; Bernardoni, V.; Brambilla, L.; Fermo, P.; Massabò, D.; Molteni, U.; Prati, P.; Valli, G.; Vecchi, R.

    2011-11-01

    The concentration of carbonates in atmospheric Particulate Matter (PM) is usually quite low. The surroundings of marble quarries are peculiar sites where the impact of carbonates in PM levels can be significant. We present here the results of a PM10 sampling campaign performed in Carrara (Italy). The town lies between the famous marble quarries and the harbour: about 1000 trucks per day transport marble blocks and debris from the quarries to the harbour passing through the town centre. PM10 was collected on daily basis on PTFE filters analyzed by Energy-Dispersive X-Ray Fluorescence (ED-XRF) and Ion-Chromatography (IC). Carbonate concentration was measured by a non-destructive Infrared Spectroscopy analysis (FT-IR). Time series of elemental (Na-Pb by ED-XRF), ionic (SO 42-, NH 4+ by ion-chromatography) and carbonate (by FT-IR) concentration values were merged in a unique data set and a PMF analysis singled out the major PM10 sources in the area. Marble transportation turned out to be the major pollution source in the town accounting to PM10 for about 36%; this corresponded to a CaCO 3 average level of about 8 μg m -3 during working days. The FT-IR analysis was a crucial part of the work and an ad-hoc analytical procedure was specifically set up, calibrated, and tested as described in the text.

  11. Traffic emissions of elemental carbon (EC) and organic carbon (OC) and their contribution to PM2.5 and PM10 urban background concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Keuken, M.P. [Netherlands Organization for Applied Scientific Research TNO, Delft (Netherlands); Ten Brink, H.M. [ECN Biomass, Coal and Environmental Research, Petten (Netherlands)

    2009-09-15

    The contribution of carbon to particulate matter is larger in urban areas than outside those areas. The increment in urban EC and OC concentrations was found mainly to be caused by traffic emissions. The average annual increment was about 0.5 {mu}g/m{sup 3}. As a consequence, the potential to reduce urban background concentrations by abatement of traffic exhaust emissions, is small. However, from a health point of view, a reduction of carbon in PM is believed to be important.

  12. Three ways to solve the orbit of KIC11558725: a 10 day beaming sdB+WD binary with a pulsating subdwarf

    CERN Document Server

    Telting, J H; Baran, A S; Bloemen, S; Reed, M D; Oreiro, R; Farris, L; Ottosen, T A; Aerts, C; Kawaler, S D; Heber, U; Prins, S; Green, E M; Kalomeni, B; O'Toole, S J; Mullally, F; Sanderfer, D T; Smith, J C; Kjeldsen, H

    2012-01-01

    The recently discovered subdwarf B (sdB) pulsator KIC11558725 features a rich g-mode frequency spectrum, with a few low-amplitude p-modes at short periods, and is a promising target for a seismic study aiming to constrain the internal structure of this star, and of sdB stars in general. We have obtained ground-based spectroscopic Balmer-line radial-velocity measurements of KIC11558725, spanning the 2010 and 2011 observing seasons. From these data we have discovered that KIC11558725 is a binary with period P=10.05 d, and that the radial-velocity amplitude of the sdB star is 58 km/s. Consequently the companion of the sdB star has a minimum mass of 0.63 M\\odot, and is therefore most likely an unseen white dwarf. We analyse the near-continuous 2010-2011 Kepler light curve to reveal orbital Doppler-beaming light variations at the 238 ppm level, which is consistent with the observed spectroscopic orbital radial-velocity amplitude of the subdwarf. We use the strongest 70 pulsation frequencies in the Kepler light cur...

  13. Carbon supported nanoparticles Pt Ru (Pt Ru/C electrocatalysts) prepared using electron beam irradiation; Preparacao de nanoparticulas de PtRu suportadas em carbono (eletrocatalisadores PtRu/C) utilizando feixe de eletrons

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Dionisio F. da; Oliveira Neto, Almir; Pino, Eddy S.; Linardi, Marcelo; Spinace, Estevam V. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Programa de Celulas a Combustivel], e-mail: espinace@ipen.br, e-mail: dfsilva@ipen.br

    2006-07-01

    Carbon-supported Pt Ru (electrocatalysts PtRu/C nanoparticles) were prepared submitting a water/ethylene glycol mixture containing Pt(IV) and Ru(III) ions and the carbon support to electron beam irradiation. The PtRu/C electrocatalysts were characterized by EDX, XRD and cyclic voltammetry and tested for methanol electro-oxidation aiming fuel cell application. The obtained PtRu/C electrocatalysts were more active for methanol electro-oxidation than the commercial PtRu/C ETEK electrocatalyst at ambient temperature. (author)

  14. Hydrated copper ion chemistry: guided ion beam and computational investigation of Cu2+(H2O)n (n = 7-10) complexes.

    Science.gov (United States)

    Armentrout, Peter B; Sweeney, Andrew F

    2015-01-01

    Cross sections for the threshold collision-induced dissociation of Cu(2+)(H(2)O)(n), where n = 8 - 10, are measured using a guided ion beam tandem mass spectrometer. The primary dissociation pathway is found to be loss of a single water molecule followed by the sequential loss of additional water molecules until n = 8, at which point charge separation to form CuOH(+)(H(2)O)(4) (+) H(+)(H(2)O)(3) is observed to occur at a slightly lower energy than loss of a water molecule. Competition from charge separation prohibits the formation of appreciable amounts of the n = 7 or smaller complexes as reactants in the source. These findings indicate that Cu(2+) has a critical size of 8. Analysis of the data using statistical modeling techniques that account for energy distributions and lifetime effects yields primary and sequential bond dissociation energies (BDEs) for loss of one and two water molecules from n = 8 - 10 complexes as well as the barrier for charge separation from n = 8. More speculative analysis extends the thermochemistry obtained down to n = 5 and 6. Theoretical BDEs are determined from quantum chemical calculations using structures optimized at the B3LYP/6 311(+)G(d,p) level along with the lowest-energy isomers suggested by single point energies at the MP2(full), M06, B3LYP, and B3P86 levels of theory using a 6- 311(+)G(2d,2p) basis set. BDEs at 0K are converted to 298 K thermodynamic values using a rigid rotor/harmonic oscillator approximation. Experimental and theoretical entropies of activation suggest that a third solvent shell forms at n = 9, in accord with previous findings. The present work represents the first experimentally determined hydration enthalpies for the Cu(2+)(H(2)O)n system. PMID:26307731

  15. Efficacy and safety of 10,600-nm carbon dioxide fractional laser on facial skin with previous volume injections

    Directory of Open Access Journals (Sweden)

    Josiane Hélou

    2013-01-01

    Full Text Available Background: Fractionated carbon dioxide (CO 2 lasers are a new treatment modality for skin resurfacing. The cosmetic rejuvenation market abounds with various injectable devices (poly-L-lactic acid, polymethyl-methacrylate, collagens, hyaluronic acids, silicone. The objective of this study is to examine the efficacy and safety of 10,600-nm CO 2 fractional laser on facial skin with previous volume injections. Materials and Methods: This is a retrospective study including 14 patients treated with fractional CO 2 laser and who have had previous facial volume restoration. The indication for the laser therapy, the age of the patients, previous facial volume restoration, and side effects were all recorded from their medical files. Objective assessments were made through clinical physician global assessment records and improvement scores records. Patients′ satisfaction rates were also recorded. Results: Review of medical records of the 14 patients show that five patients had polylactic acid injection prior to the laser session. Eight patients had hyaluronic acid injection prior to the laser session. Two patients had fat injection, two had silicone injection and one patient had facial thread lift. Side effects included pain during the laser treatment, post-treatment scaling, post-treatment erythema, hyperpigmentation which spontaneously resolved within a month. Concerning the previous facial volume restoration, no granulomatous reactions were noted, no facial shape deformation and no asymmetry were encountered whatever the facial volume product was. Conclusion: CO 2 fractional laser treatments do not seem to affect facial skin which had previous facial volume restoration with polylactic acid for more than 6 years, hyaluronic acid for more than 0.5 year, silicone for more than 6 years, or fat for more than 1.4 year. Prospective larger studies focusing on many other variables (skin phototype, injected device type are required to achieve better

  16. 碳纤维布加固锈蚀钢筋混凝土梁的疲劳性能试验%FATIGUE PERFORMANCE OF CORRODED RC BEAMS STRENGTHENED WITH CARBON FIBER COMPOSITE SHEETS

    Institute of Scientific and Technical Information of China (English)

    宋力; 张伟平

    2009-01-01

    完成了粘贴碳纤维布加固锈蚀钢筋混凝土梁的疲劳试验.试验结果表明,碳纤维布加固可以明显提高梁的疲劳寿命,减小梁的变形,提高梁的疲劳抗裂性能.因此,粘贴碳纤维布可以较大提高锈蚀钢筋混凝土梁的疲劳性能,延长锈蚀钢筋混凝土结构的使用寿命,为碳纤维布加固锈蚀钢筋混凝土结构的长期疲劳性能研究提供了试验依据.%Tests,including two corroded reinforced concrete(RC)beams strengthened with carbon fiber composite sheets and one corroded RC beams,were carried out under fatigue loadings.It is found that the fa-tigue life of beams strengthened with csrbon fiber composite sheets is greatly improved,and fatigue delforma-tion is decreased,and performance of anti-crack is obviously improved.Thus,after stuengthening with exter-ally bonded carbon fiber composite sheets,the flexural fatigue behavior of a corroded RC beam may be con-siderably improveded,the fatigue life of corrosion RC structures may be obviously increased.It sets up the test-base for the study of long-term performance of corroded RC beam reinforced with carbon fiber composite she-ets.

  17. Extended phase-correlated rescanning irradiation to improve dose homogeneity in carbon-ion beam liver treatment

    International Nuclear Information System (INIS)

    We previously reported that an adequate number of simple layered phase-correlated rescanning (PCR) irradiations improve dose conformation to a moving target. However, if PCR is not completed within a single gating window due to the particular irradiation specifications selected in advance and/or layer size, the iso-energy layer is completed using next gating window, and the effect of rescanning is effectively nullified. To solve this problem, we developed extended PCR irradiation. Extended PCR is conceptually based on simple PCR. It differs in that the dose rate is adjusted to irradiate the number of rescans within multiple gating windows when simple PCR is not finished within a single gating window. This process is repeated until the total prescribed dose is given. Here, 4DCT imaging was performed under free-breathing conditions in 10 patients with hepatocellular carcinoma. 4D dose distributions for a single field approach were performed with simple PCR and extended PCR using 4DCT. A total dose of 11.25 Gy(RBE) was administered to the field-specific target volume. The number of rescans was changed from 1 to 10. Respiratory gating of a 30% duty cycle around exhalation was applied. Dose assessment metrics (CTV-D95, CTV-Dmin, CTV-Dmax) with PCR improved with an increasing number of rescans, and largely plateaued at five or more rescans. Minimum D95 and Dmin values, and maximum Dmax and HI values fluctuated at odd and even numbers of rescans. Extended PCR improved all dose assessment metrics whereas PCR did not. Values with extended PCR were mostly constant with three or more rescans, or in other words independent of the number of rescans. Extended PCR improved dose conformation to a moving target with greater efficacy than simple PCR when more than two gating windows were necessary. Extended PCR can be applied to irradiation machines having a low maximum dose rate. (paper)

  18. Nonlinear beam-beam resonances

    International Nuclear Information System (INIS)

    Head-on collisions of bunched beams are considered, assuming the two colliding beams have opposite charges. A few experimental observations are described. The single resonance analysis is developed that is applicable to the strong-weak case of the beam-beam interaction. In this case, the strong beam is unperturbed by the beam-beam interaction; motions of the weak beam particles are then analyzed in the presence of the nonlinear electromagnetic force produced by the strong beam at the collision points. The coherent motions of the two coupled strong beams are shown to exhibit distinct nonlinear resonance behavior. 16 refs., 22 figs

  19. Effect of beam expansion loss in a carbon nanotube-doped PVA film on passively mode-locked erbium-doped fiber lasers with different feedback ratios

    International Nuclear Information System (INIS)

    The effect of beam expansion induced divergent loss in a single-wall carbon nanotube (SWCNT) doped polyvinyl alcohol (PVA) based ultrafast saturable absorber (SA) film thickness on the passive mode-locking (PML) performances of erbium-doped fiber lasers are demonstrated. The variation on the PML pulsewidth of the EDFL is discussed by changing the SWCNT-PVA SA film thicknesses, together with adjusting the pumping power and the intra-cavity feedback ratio. An almost 6 dB increment of divergent loss when enlarging the SWCNT-PVA based SA film thickness from 30–130 µm is observed. When shrinking the SA thickness to 30 µm at the largest pumping power of 52.5 mW, the optical spectrum red-shifts to 1558.8 nm with its 3 dB spectral linewidth broadening up to 2.7 nm, while the pulse has already entered the soliton regime with multi-order Kelly sidebands aside the spectral shoulder. The soliton pulsewidth is as short as 790 fs, which is much shorter than those obtained with other thicker SWCNT doped PVA polymer film based SAs; therefore, the peak power from the output of the PML-EDFL is significantly enlarged accompanied by a completely suppressed residual continuous-wave level to achieve the largest on/off extinction ratio. The main mechanism of pulse shortening with reducing thickness of SWCNT doped PVA polymer film based SA is attributed to the limited beam expansion as well as the enlarged modulation depth, which results in shortened soliton pulsewidth with a clean dc background, and broadened spectrum with enriched Kelly sidebands. The increase of total SWCNT amount in the thicker SA inevitably causes a higher linear absorption; hence, the mode-locking threshold also rises accordingly. By enlarging pumping power from 38.5–52.5 mW, the highest ascent on pulse extinction of up to 32 dB is observed among all kinds of feedback conditions. Nevertheless, the enlargement on the extinction slightly decays with increasing the feedback ratio from 30–90

  20. RBE and OER values from 10-day growth inhibition of Vicia faba roots exposed to high-energy neutron and pion beams

    International Nuclear Information System (INIS)

    Radiobiological studies using beams of 172 MeV/c negative and positive pions and 600 MeV neutrons are reported, using growth inhibition of Vicia faba primary roots as the test system. Particular emphasis is put on an investigation of the variation of the RBE and OER values along the beams absorbed in water. The effects of position in the beam, of the dose rate, and of the nuclear-interaction dose component are considered, and comparisons made using 60Co gamma-rays as the reference radiation. The observed biological effects are discussed in the light of their possible radiobiological and radiotherapeutic applications. (Auth.)